WorldWideScience

Sample records for chu radiation test

  1. Radiated Emissions Test Approach

    Science.gov (United States)

    2015-10-02

    1. Draft Department of Transportation (DOT) Test Plan to Develop : Interference Tolerance Masks for GNSS Receivers in the L1 : Radiofrequency Band (1559 1610 MHz) provides high level : overview of radiated emissions test setup : 2. Presenta...

  2. Radiation Belt Test Model

    Science.gov (United States)

    Freeman, John W.

    2000-10-01

    Rice University has developed a dynamic model of the Earth's radiation belts based on real-time data driven boundary conditions and full adiabaticity. The Radiation Belt Test Model (RBTM) successfully replicates the major features of storm-time behavior of energetic electrons: sudden commencement induced main phase dropout and recovery phase enhancement. It is the only known model to accomplish the latter. The RBTM shows the extent to which new energetic electrons introduced to the magnetosphere near the geostationary orbit drift inward due to relaxation of the magnetic field. It also shows the effects of substorm related rapid motion of magnetotail field lines for which the 3rd adiabatic invariant is violated. The radial extent of this violation is seen to be sharply delineated to a region outside of 5Re, although this distance is determined by the Hilmer-Voigt magnetic field model used by the RBTM. The RBTM appears to provide an excellent platform on which to build parameterized refinements to compensate for unknown acceleration processes inside 5Re where adiabaticity is seen to hold. Moreover, built within the framework of the MSFM, it offers the prospect of an operational forecast model for MeV electrons.

  3. Radiation from Cardiac Imaging Tests

    Science.gov (United States)

    ... his or her test will be performed with attention paid to keeping radiation exposure low. Two Questions ... based, whereby less radiation is used to take pictures of skinnier patients. Questions for CT Angiograms Do ...

  4. Electric Dipole Antennas With Magnetic-Coated PEC Cores: Reaching the Chu Lower Bound on Q

    DEFF Research Database (Denmark)

    Kim, Oleksiy S.

    2012-01-01

    The radiation properties of spherical electric dipole antennas with electric current excitation and material-coated perfectly electrically conducting (PEC) cores are investigated analytically using vector spherical wave functions. Closed-form expressions for electric and magnetic stored energy...... as well as the radiation quality factor $Q$ are derived. Using these, it is shown that properly selected magnetic coating and radius of the PEC core vastly reduce the internal stored energy, and thus make the $Q$ of an electric dipole antenna approach the Chu lower bound....

  5. Reaching the Chu Lower Bound on Q With Magnetic Dipole Antennas Using a Magnetic-Coated PEC Core

    DEFF Research Database (Denmark)

    Kim, Oleksiy S.; Breinbjerg, Olav

    2011-01-01

    We analytically solve the radiation problem for a spherical magnetic dipole antenna with a material-coated perfectly electrically conducting core. Using the closed-form expressions derived for the internal and external stored energies as well as for the radiation quality factor $Q$, we determine...... tends to infinity, the internal stored energy vanishes, and the $Q$ reaches the Chu lower bound, irrespective of the antenna electrical size $ka$ and permittivity of the coating....

  6. Properties of Sub-Wavelength Spherical Antennas With Arbitrarily Lossy Magnetodielectric Cores Approaching the Chu Lower Bound

    DEFF Research Database (Denmark)

    Hansen, Troels Vejle; Kim, Oleksiy S.; Breinbjerg, Olav

    2014-01-01

    For a spherical antenna exciting any arbitrary spherical mode, we derive exact closed-form expressions for the dissipated power and stored energy inside (and outside) the lossy magneto-dielectric spherical core, as well as the radiated power, radiation efficiency, and thus the radiation quality...... an increasing magnetic loss tangent initially leads to a decreasing radiation quality factor, but in the limit of a perfect magnetic conductor (PMC) core the dissipated power tends to zero and the radiation quality factor reaches the fundamental Chu lower bound....

  7. Radiation pressure actuation of test masses

    International Nuclear Information System (INIS)

    Garoi, F; Ju, L; Zhao, C; Blair, D G

    2004-01-01

    In this paper, we investigate the use of radiation pressure force as test mass actuation for laser interferometer gravitational wave detectors. It is shown that it is viable to provide radiation pressure control on test masses for frequencies above ∼0.2 Hz in high performance vibration isolation systems. A very low mass, low frequency resonator has been used to verify that radiation pressure force is not corrupted by other forces such as due to radiometer effects

  8. Experimental test of liquid droplet radiator performance

    Science.gov (United States)

    Mattick, A. T.; Simon, M. A.

    The liquid droplet radiator (LDR) is a heat rejection system for space power systems wherein an array of heated liquid droplets radiates energy directly to space. The use of submillimeter droplets provides large radiating area-to-mass ratio, resulting in radiator systems which are several times lighter than conventional solid surface radiators. An experiment is described in which the power radiated by an array of 2300 streams of silicone oil droplets is measured to test a previously developed theory of the LDR radiation process. This system would be capable of rejecting several kW of heat in space. Furthermore, it would be suitable as a modular unit of an LDR designed for 100-kW power levels. The experiment provided confirmation of the theoretical dependence of droplet array emissivity on optical depth. It also demonstrated the ability to create an array of more than 1000 droplet streams having a divergence less than 1 degree.

  9. Zadoff-Chu coded ultrasonic signal for accurate range estimation

    KAUST Repository

    AlSharif, Mohammed H.

    2017-11-02

    This paper presents a new adaptation of Zadoff-Chu sequences for the purpose of range estimation and movement tracking. The proposed method uses Zadoff-Chu sequences utilizing a wideband ultrasonic signal to estimate the range between two devices with very high accuracy and high update rate. This range estimation method is based on time of flight (TOF) estimation using cyclic cross correlation. The system was experimentally evaluated under different noise levels and multi-user interference scenarios. For a single user, the results show less than 7 mm error for 90% of range estimates in a typical indoor environment. Under the interference from three other users, the 90% error was less than 25 mm. The system provides high estimation update rate allowing accurate tracking of objects moving with high speed.

  10. Zadoff-Chu coded ultrasonic signal for accurate range estimation

    KAUST Repository

    AlSharif, Mohammed H.; Saad, Mohamed; Siala, Mohamed; Ballal, Tarig; Boujemaa, Hatem; Al-Naffouri, Tareq Y.

    2017-01-01

    This paper presents a new adaptation of Zadoff-Chu sequences for the purpose of range estimation and movement tracking. The proposed method uses Zadoff-Chu sequences utilizing a wideband ultrasonic signal to estimate the range between two devices with very high accuracy and high update rate. This range estimation method is based on time of flight (TOF) estimation using cyclic cross correlation. The system was experimentally evaluated under different noise levels and multi-user interference scenarios. For a single user, the results show less than 7 mm error for 90% of range estimates in a typical indoor environment. Under the interference from three other users, the 90% error was less than 25 mm. The system provides high estimation update rate allowing accurate tracking of objects moving with high speed.

  11. La frequence des affections neuro-ophtalmologiques au CHU ...

    African Journals Online (AJOL)

    But: faire une description clinique des affections neuro-ophtalmologiques et déterminer la fréquence de ces pathologies. Méthodologie: Il s'agit d'une étude prospective menée sur une année dans le service d'ophtalmologie du CHU Sylvanus Olympio de Lomé. Etaient inclus tous cas suspect de baisse d'acuité visuelle ...

  12. ALICE Transition Radiation Detector (TRD), test beam.

    CERN Multimedia

    2003-01-01

    Electrons and positrons can be discriminated from other charged particles using the emission of transition radiation - X-rays emitted when the particles cross many layers of thin materials. To develop such a Transition Radiation Detector(TRD) for ALICE many detector prototypes were tested in mixed beams of pions and electrons, as in the example shown here.

  13. Nevada Test Site Radiation Protection Program

    Energy Technology Data Exchange (ETDEWEB)

    Radiological Control Managers' Council, Nevada Test Site

    2007-08-09

    Title 10 Code of Federal Regulations (CFR) 835, 'Occupational Radiation Protection', establishes radiation protection standards, limits, and program requirements for protecting individuals from ionizing radiation resulting from the conduct of U.S. Department of Energy (DOE) activities. 10 CFR 835.101(a) mandates that DOE activities be conducted in compliance with a documented Radiation Protection Program (RPP) as approved by DOE. This document promulgates the RPP for the Nevada Test Site (NTS), related (onsite or offsite) DOE National Nuclear Security Administration Nevada Site Office (NNSA/NSO) operations, and environmental restoration offsite projects.

  14. Deep space test bed for radiation studies

    International Nuclear Information System (INIS)

    Adams, James H.; Adcock, Leonard; Apple, Jeffery; Christl, Mark; Cleveand, William; Cox, Mark; Dietz, Kurt; Ferguson, Cynthia; Fountain, Walt; Ghita, Bogdan; Kuznetsov, Evgeny; Milton, Martha; Myers, Jeremy; O'Brien, Sue; Seaquist, Jim; Smith, Edward A.; Smith, Guy; Warden, Lance; Watts, John

    2007-01-01

    The Deep Space Test-Bed (DSTB) Facility is designed to investigate the effects of galactic cosmic rays on crews and systems during missions to the Moon or Mars. To gain access to the interplanetary ionizing radiation environment the DSTB uses high-altitude polar balloon flights. The DSTB provides a platform for measurements to validate the radiation transport codes that are used by NASA to calculate the radiation environment within crewed space systems. It is also designed to support other exploration related investigations such as measuring the shielding effectiveness of candidate spacecraft and habitat materials, testing new radiation monitoring instrumentation, flight avionics and investigating the biological effects of deep space radiation. We describe the work completed thus far in the development of the DSTB and its current status

  15. Orbiter radiator panel solar focusing test

    Science.gov (United States)

    Howell, H. R.; Rankin, J. G.

    1983-01-01

    Test data are presented which define the area around the Orbiter radiator panels for which the solar reflections are concentrated to one-sun or more. The concave shape of the panels and their specular silver/Teflon coating causes focusing of the reflected solar energy which could have adverse heating effects on equipment or astronaut extravehicular activity (EVA) in the vicinity of the radiator panels. A room ambient test method was utilized with a one-tenth scale model of the radiator panels.

  16. Electrically Small Magnetic Dipole Antennas With Quality Factors Approaching the Chu Lower Bound

    DEFF Research Database (Denmark)

    Kim, Oleksiy S.; Breinbjerg, Olav; Yaghjian, Arthur D.

    2010-01-01

    We investigate the quality factor Q for electrically small current distributions and practical antenna designs radiating the TE10 magnetic dipole field. The current distributions and the antenna designs employ electric currents on a spherical surface enclosing a magneto-dielectric material...... numerically. It is found that for a given antenna size and permittivity there is an optimum permeability that ensures the lowest possible Q, and this optimum permeability is inversely proportional to the square of the antenna electrical radius. When the relative permittivity is equal to 1, the optimum...... permeability yields the quality factor Q that constitutes the lower bound for a magnetic dipole antenna with a magneto-dielectric core. Furthermore, the smaller the antenna the closer its quality factor Q can approach the Chu lower bound. Simulated results for the TE10-mode multiarm spherical helix antenna...

  17. Guidelines for testing sealed radiation sources

    International Nuclear Information System (INIS)

    1989-01-01

    These guidelines are based on article 16(1) of the Ordinance on the Implementation of Atomic Safety and Radiation Protection dated 11 October 1984 (VOAS), in connection with article 36 of the Executory Provision to the VOAS, of 11 October 1984. They apply to the testing of sealed sources to verify their intactness, tightness and non-contamination as well as observance of their fixed service time. The type, scope and intervals of testing as well as the evaluation of test results are determined. These guidelines also apply to the testing of radiation sources forming part of radiation equipment, unless otherwise provided for in the type license or permit. These guidelines enter into force on 1 January 1990

  18. Helioseismic Tests of Radiative Opacities.

    Energy Technology Data Exchange (ETDEWEB)

    Guzik, J. A. (Joyce Ann); Neuforge, C. M. (Corinne M.); Keady, J. J.; Magee, N. H. (Norman H.); Bradley, P. A. (Paul A.)

    2002-01-01

    During the past fifteen years, thousands of solar acoustic oscillation modes have been measured to remarkable precision, in many cases to within 0.01%. These frequencies have been used to infer the interior structure of the sun and test the physical input to solar models. Here we summarize the procedures, input physics and assumptions for calculating a standard solar evolution model. We compare the observed and calculated sound speed profile and oscillation frequencies of solar models calibrated using the new Los Alamos LEDCOP and Livermore OPAL Rosseland mean opacities for the same element mixture. We show that solar oscillations are extremely sensitive to opacities, with opacity differences of only a few percent producing an easily detectable effect on the sound speed and predicted frequencies. The oscillation data indicate that agreement would be improved by an opacity increase of several percent below the convection zone for both the LEDCOP and OPAL opacities.

  19. Advanced CMOS Radiation Effects Testing and Analysis

    Science.gov (United States)

    Pellish, J. A.; Marshall, P. W.; Rodbell, K. P.; Gordon, M. S.; LaBel, K. A.; Schwank, J. R.; Dodds, N. A.; Castaneda, C. M.; Berg, M. D.; Kim, H. S.; hide

    2014-01-01

    Presentation at the annual NASA Electronic Parts and Packaging (NEPP) Program Electronic Technology Workshop (ETW). The material includes an update of progress in this NEPP task area over the past year, which includes testing, evaluation, and analysis of radiation effects data on the IBM 32 nm silicon-on-insulator (SOI) complementary metal oxide semiconductor (CMOS) process. The testing was conducted using test vehicles supplied by directly by IBM.

  20. Utilization of radiation in non destructive tests

    International Nuclear Information System (INIS)

    Lopes, R.T.; Jesus, E.F.O. de; Junqueira, M.M.; Matos, J.A. de; Castello Branco, L.M.; Barros Junior, J.D.; Borges, J.C.

    1987-01-01

    The Nuclear Instrumentation Laboratory from COPPE/UFRJ has been developed techniques for using nuclear radiations to obtain images for non-destructive materials testing and medicine. With this objective, some prototypes of transmission computerized tomography systems using parallel beans and fan beans, with computer automation, including the mathematical process of image reprocessing and presentation in videos or printers are constructed [pt

  1. Standardization of penetrating radiation testing system

    International Nuclear Information System (INIS)

    Wiley, P.A.; Aronson, H.L.

    1979-01-01

    Standardization is provided to control system gain of a penetrating radiation testing system by periodically inspecting a reference object in the same manner as the product samples so as to generate a stabilization signal which is compared to a reference signal. The difference, if any, between the stabilization signal and the reference signal is integrated and the integrated signal is used to correct the gain of the system

  2. Compilation of radiation damage test data. I

    International Nuclear Information System (INIS)

    Schoenbacher, H.; Stolarz-Izycka, A.

    1979-01-01

    This report summarizes radiation damage test data on commercially available organic cable insulation and jacket materials: ethylene-propylene rubber, Hypalon, neoprene rubber, polyethylene, polyurethane, polyvinylchloride, silicone rubber, etc. The materials have been irradiated in a nuclear reactor to integrated absorbed doses from 5 X 10 5 to 5 X 10 6 Gy. Mechanical properties, e.g. tensile strength, elongation at break, and hardness, have been tested on irradiated and non-irradiated samples. The results are presented in the form of tables and graphs, to show the effect of the absorbed dose on the measured properties. (Auth.)

  3. Modern instrumentation for radiation introscopic testing of welding quality

    International Nuclear Information System (INIS)

    Sosnin, F.R.

    1985-01-01

    Modern instrumenlation used for radiation introscopy of welded joints is discussed. the absolute (relative) sensitivity of radiation testing, resolution range, efficiency are considered as basic parameters of introscopes. The characteristics of fluoroscopes, radiation-television installations with the external scintillator and radiative image converter as well as with X-ray vidicons are given. The characterisitcs of radiation introscopes with manipulators to move objects being tested are analysed as well as digitized radiation introscopes

  4. Design of online testing system of material radiation resistance

    International Nuclear Information System (INIS)

    Wan Junsheng; He Shengping; Gao Xinjun

    2014-01-01

    The capability of radiation resistance is important for some material used in some specifically engineering fields. It is the same principal applied in all existing test system that compares the performance parameter after radiation to evaluate material radiation resistance. A kind of new technique on test system of material radiation resistance is put forward in this paper. Experimentation shows that the online test system for material radiation resistance works well and has an extending application outlook. (authors)

  5. Non Volatile Flash Memory Radiation Tests

    Science.gov (United States)

    Irom, Farokh; Nguyen, Duc N.; Allen, Greg

    2012-01-01

    Commercial flash memory industry has experienced a fast growth in the recent years, because of their wide spread usage in cell phones, mp3 players and digital cameras. On the other hand, there has been increased interest in the use of high density commercial nonvolatile flash memories in space because of ever increasing data requirements and strict power requirements. Because of flash memories complex structure; they cannot be treated as just simple memories in regards to testing and analysis. It becomes quite challenging to determine how they will respond in radiation environments.

  6. Radiation exposures from nuclear tests at the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Dunning, G M

    1958-12-01

    A summary of the pertinent data on radiation exposures from nuclear tests in Nevada is presented. The data are presented in categories of external ..gamma.. radiation, activity concentrations in air, and activity concentrations in water. Methods used to estimate exposure and to evaluate data are described. The data are tabulated. The maximum external exposure was 7 to 8 r for 15 persons involved. In terms of relatively large populations, the average exposure for the 1,000,000 people living nearest the site was at the rate of 1/2 r/30 yr. The highest concentration of fallout activity in the air was about 1.3 ..mu..c/m/sup 3/ averaged over the 30 hr that the activity was present in significant quantities. The highest concentration of fallout activity in a potential drinking water supply was about 1.4 x 10/sup -/ ..mu..c/me extrapolated to D + 3 days. Evaluation of these data is given.

  7. Compilation of radiation damage test data

    International Nuclear Information System (INIS)

    Schoenbacher, H.; Tavlet, M.

    1989-01-01

    This report summarizes radiation damage test data on commercially available organic cable insulation and jacket materials: Ethylene-propylene rubbers, polyethylenes, polyurethanes, silicone rubbers, and copolymers based on polyethylene. The materials have been irradiated either in a nuclear reactor, or with a cobalt-60 source, or in the CERN accelerators, at different dose rates. The absorbed doses were between 10 3 and 5x10 6 Gy. Mechanical properties, e.g. tensile strength, elongation at break, and hardness, have been tested on irradiated and non-irradiated samples, according to the recommendations of the International Electrotechnical Commission. The results are presented in the form of tables and graphs to show the effect of the absorbed dose on the measured properties. (orig.)

  8. Compilation of radiation damage test data. II

    International Nuclear Information System (INIS)

    Schoenbacher, H.; Stolarz-Izycka, A.

    1979-01-01

    This report summarizes radiation damage test data on thermosetting and thermoplastic resins, with the main emphasis on epoxy resins used for magnet coil insulations. Also, other materials such as polyesters, phenolics, polyurethanes, silicones, etc., are represented. The materials have been irradiated in a nuclear reactor to integrated absorbed doses between 5x10 6 Gy and 1x10 8 Gy. The mechanical properties, e.g. the flexural strength, deflection at break, and tangent modulus of elasticity, have been measured on irradiated and non-irradiated samples. The results are given as variation of these parameters versus absorbed dose and are presented in the form of tables and graphs. The tested materials are catalogued in alphabetical order. (Auth.)

  9. Testing the effects from dark radiation

    International Nuclear Information System (INIS)

    Zhang Yi; Gong Yungui

    2013-01-01

    In this paper, the effects of dark radiation (DR) are tested. Theoretically, the phase-space analysis method is applied to check whether the model is consist with the history of our universe which shows positive results. Observationally, by using the observational data (SuperNovae Legacy Survey (SNLS), Wilkinson Microwave Anisotropy Probe 9 Years Result (WMAP9), Planck First Data Release (PLANCK), baryon acoustic oscillations (BAO), Hubble parameter data (H(z)) and Big Bang nucleosynthesis (BBN)), the DR is found to have the effect of wiping out the tension between the SNLS data and the other data in a flat ΛCDM model. The effects of DR also make the best fit value of N eff slightly larger than 3.04. (paper)

  10. Nuclear technology in materials testing and radiation protection

    International Nuclear Information System (INIS)

    Neider, R.

    1975-01-01

    A report of the 1974 activities of the laboratories for physical and measuring technical fundamentals, radiation effects and radiation protection, application of radionuclides and testing of radioactive materials of the Bundesanstalt fuer Materialpruefung (BAM) is given. (RW/LH) [de

  11. Radiation legacy of nuclear tests at the Semipalatinsk test site in the light of requirements ensuring radiation safety performance

    International Nuclear Information System (INIS)

    Logachev, V.A.; Logacheva, L.A.

    2005-01-01

    Peculiarities of nuclear tests radiation legacy at the Semipalatinsk test site (STS) are shown in the light of performance of requirements ensuring radiation safety, decrease radiation contamination levels in environment and minimize exposure of radiation for population residing contaminated areas by radioactive fallout. The paper provides data on characterization of peculiarities of the STS operation legacy based on review of archival data of the former 3-d General Administration under USSR Ministry of Health. (author)

  12. Experimental test of liquid droplet radiator performance

    International Nuclear Information System (INIS)

    Mattick, A.T.; Simon, M.A.

    1986-01-01

    This liquid droplet radiator (LDR) is evolving rapidly as a lightweight system for heat rejection in space power systems. By using recirculating free streams of submillimeter droplets to radiate waste energy directly to space, the LDR can potentially be an order of magnitude lighter than conventional radiator systems which radiate from solid surfaces. The LDR is also less vulnerable to micrometeoroid damage than are conventional radiators, and it has a low transport volume. Three major development issues of this new heat rejection system are the ability to direct the droplet streams with sufficient precision to avoid fluid loss, radiative performance of the array of droplet streams which comprise the radiating elements of the LDR, and the efficacy of the droplet stream collector, again with respect to fluid loss. This paper reports experimental results bearing on the first two issues - droplet aiming in a multikilowatt-sized system, and radiated power from a large droplet array. Parallel efforts on droplet collection and LDR system design are being pursued by several research groups

  13. [Stoma use in the general surgery service of CHU Gabriel Touré].

    Science.gov (United States)

    Traore, A; Diakite, I; Togo, A; Dembele, B T; Kante, L; Coulibaly, Y; Keita, M; Diango, D M; Diallo, A; Diallo, G

    2010-01-01

    Were to determine the frequency, to describe the clinical and therapeutic aspects digestive stoma. It was about six months an exploratory study from January 1st to June 30th, 2008 in the department of surgery general of the CHU Gabriel Touré. Were included in this study all the patients carrying a enter stoma or a colostomy, old of more than 15 ans. The digestive dents, the other types of stoma and the patients old of less than 15 years, were excluded. The results were analyzed by the software Epi information version 6.4 Fr, the tests of Khi 2 and Student with a threshold of significance for P stomiale 4 cas (12.5%), the suppuration peristomial 3 cas (9.4%), the releasing of Stoma 3 cas (9.4%), the retraction of the stoma 3 cas (9.4%),the psychological disorders 3 cases (9.4%), the hemorrhage 2 cas (6.3), necroses peristomial 2 cas (3.1%), septic shock 2 cas (6.3%), and 1 cas (3.1%) of evisceration, obstruction of the bowels, shock hypovolemic. The intermediate duration of hospitalization was of 37,5 jours with a standard deviation = 13.58 and extremes varying between 02-73 days. Death rate was of 9.4%. The assumption of responsibility of the stomies is difficult in the absence of stomatherapeutes, and of the high cost of the parenteral nutrition in our context .

  14. Radiation safety in welding and testing

    International Nuclear Information System (INIS)

    King, B.E.; Malaxos, M.; Hartley, B.M.

    1985-01-01

    There are a number of ways of achieving radiation safety in the workplace. The first is by engineering radiation safety into the equipment, providing shielded rooms and safety interlocks. The second is by following safe working procedures. The National Health and Medical Research Council's Code of practice for the control and safe handling of sealed radioactive sources used in industrial radiography (1968) sets out the standards which must be met by equipment to be used in industrial radiography

  15. Mortalite liee au VIH chez les enfants aux Chu campus et tokoin de ...

    African Journals Online (AJOL)

    Introduction. Le but de ce travail était d'étudier la mortalité liée au VIH chez les enfants séropositifs aux CHU-Campus et Tokoin de Lomé. Patients et méthode. Il s'est agi d'une étude prospective qui s'est déroulée dans les services de pédiatrie des CHU-Campus et Tokoin de Lomé et qui a couvert une période de 6 mois ...

  16. Thermal response of a can handling unit (CHU) to a postulated plutonium hydride burn

    International Nuclear Information System (INIS)

    Crea, B.A.; Heard, F.J.

    1998-01-01

    A series of analyses were performed to support the design of the Can Handling Unit (CHU). The subject analyses focused on determining the time to repressurize a subatmospheric storage can containing plutonium metal versus the initial hole size and the transient thermal response to a postulated chemical reaction of 150 grams of plutonium hydride. Limiting the amount of gaseous reactants either by inerting the CHU or using a very small hole size for the initial opening appears to be a viable method of controlling the rate of the exothermic chemical reactions and system temperatures

  17. Evaluation of methods to leak test sealed radiation sources

    International Nuclear Information System (INIS)

    Arbeau, N.D.; Scott, C.K.

    1987-04-01

    The methods for the leak testing of sealed radiation sources were reviewed. One hundred and thirty-one equipment vendors were surveyed to identify commercially available leak test instruments. The equipment is summarized in tabular form by radiation type and detector type for easy reference. The radiation characteristics of the licensed sources were reviewed and summarized in a format that can be used to select the most suitable detection method. A test kit is proposed for use by inspectors when verifying a licensee's test procedures. The general elements of leak test procedures are discussed

  18. PEP radiation shielding tests in SLAC A Beam

    International Nuclear Information System (INIS)

    Ash, W.; DeStaebler, H.; Harris, J.; Jenkins, T.; Murray, J.

    1977-09-01

    Radiation shielding tests designed to simulate possible conditions in and around the PEP experimental halls were conducted. The SLAC A Beam was targeted in the block tunnel at a point about midway between End Station A and Beam Dump East. At that site it was relatively easy to rearrange the concrete block structure to simulate the various shielding configurations under consideration for PEP. Extensive surveys of neutron and ionizing radiation were made. Complete results of the shielding tests are given

  19. Testing of ionizing radiation applicability in storing vegetables and fruit

    Energy Technology Data Exchange (ETDEWEB)

    Salkova, Z.

    1980-01-01

    The results are briefly summarized of experimental testing the radiation inhibition of onion, garlic and potatoes germination. The results achieved in studying radiation pasteurization of soft fruit are also discussed. The results are evaluated especially from the standpoint of germination inhibition, reducing material losses, phytopathogenic microbiota suppression and storage extension of vegetables and fruit. The factors are analyzed affecting the final results and the conditions are examined of testing pilot-plant radurization techniques for onion and garlic.

  20. Testing of ionizing radiation applicability in storing vegetables and fruit

    International Nuclear Information System (INIS)

    Salkova, Z.

    1980-01-01

    The results are briefly summarized of experimental testing the radiation inhibition of onion, garlic and potatoes germination. The results achieved in studying radiation pasteurization of soft fruit are also discussed. The results are evaluated especially from the standpoint of germination inhibition, reducing material losses, phytopathogenic microbiota suppression and storage extension of vegetables and fruit. The factors are analyzed affecting the final results and the conditions are examined of testing pilot-plant radurization techniques for onion and garlic. (author)

  1. Radiation damage testing at the SSC [Superconducting Super Collider

    International Nuclear Information System (INIS)

    Chinowsky, W.; Thun, R.

    1990-06-01

    A Task Force on Radiation Damage Testing met at the SSC Laboratory on March 5--6, 1990. This Task Force was asked to assess the availability of appropriate facilities for radiation damage tests of SSC detector materials and components. The Task Force was also instructed to review the techniques and standards for conducting such tests. Semiconductors were considered separately from other detector materials. Radiation damage test of electronic devices generally require exposures to both ionizing radiation and neutrons, whereas non-electric components such as plastic scintillating materials, adhesives, cable insulation, and other organic polymers are adequately tested with ionizing radiation only. Test standards are discussed with respect to irradiation techniques, environmental factors, dosimetry, and mechanisms whereby various materials are damaged. It is emphasized that radiation sources should be chosen to duplicate as much as possible the expected SSC environment and that the effects from ionizing particles and from neutrons be investigated separately. Radiation damage tests at reactors must be designed with particular care complex spectra of neutrons and gamma rays are produced at such facilities. It is also essential to investigate dose-rate effects since they are known to be important in many cases. The required irradiations may last several months and are most easily carried out with dedicated radioactive sources. Environmental factors such as the presence of oxygen when testing plastic scintillators, or temperature when measuring semiconductor annealing effects, must also be taken into account. The importance of reliable dosimetry is stressed and suitable references cited. Finally, it is noted that an understanding of the mechanisms for radiation damage in semiconductor and other materials is important in planning irradiations and evaluating results

  2. Test on radiation-withstanding properties of sensors

    International Nuclear Information System (INIS)

    Yagi, Hideyuki; Kakuta, Tsunemi; Ara, Katsuyuki

    1986-01-01

    In order to use for the remote operation system or in-line measuring system in the facilities handling radioactive substances, the development of the sensors having strengthened radiation-withstanding performance has been advanced. As a part of it, efforts have been exerted to phenomenologically grasp the radiation effect on various sensors and their materials, and to acquire the basic data. Irradiation test was carried out on solid image pick-up elements, optical parts eddy current sensors, pressure sensitive rubber, photo-electric proximity sensors and others, and the knowledge on their deterioration was obtained. Besides, the sensors and video-cameras having improved radiation-withstanding performance were made for trial, and the performance was tested. The interim report on these test results is made. By a series of the irradiation tests reported here, the basic data required for giving the guideline to the development of radiation withstanding sensors were able to be obtained. But in the present irradiation test, the number of specimens was too small to assure the radiation withstanding performance. In order to improve further the radiation withstanding performance of these sensors, it is necessary to carry out the irradiation test on such elements as condensers, diodes and ICs to accumulate the basic data. (Kako, I.)

  3. Report on the Radiation Effects Testing of the Infrared and Optical Transition Radiation Camera Systems

    Energy Technology Data Exchange (ETDEWEB)

    Holloway, Michael Andrew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-04-20

    Presented in this report are the results tests performed at Argonne National Lab in collaboration with Los Alamos National Lab to assess the reliability of the critical 99Mo production facility beam monitoring diagnostics. The main components of the beam monitoring systems are two cameras that will be exposed to radiation during accelerator operation. The purpose of this test is to assess the reliability of the cameras and related optical components when exposed to operational radiation levels. Both X-ray and neutron radiation could potentially damage camera electronics as well as the optical components such as lenses and windows. This report covers results of the testing of component reliability when exposed to X-ray radiation. With the information from this study we provide recommendations for implementing protective measures for the camera systems in order to minimize the occurrence of radiation-induced failure within a ten month production run cycle.

  4. AHP 21: Architecture in The Bo, 'Brug Chu, and Co Ne Counties, Gannan Tibetan Autonomous Prefecture, Gansu

    Directory of Open Access Journals (Sweden)

    Chos dbyings rdo rje ཆོས་དབྱིངས་རྡོ་རྗེ།

    2012-12-01

    Full Text Available Thirty-nine images of architecture in The bo, 'Brug chu, and Co ne counties (Gannan Tibetan Autonomous Prefecture, Gansu Province, China are presented. The author also relates his experiences of travelling through the area in 2010.

  5. Estimation of radiation dose received by the radiation workers during radiographic testing

    International Nuclear Information System (INIS)

    Mohammed, N. A. H. O.

    2013-08-01

    This study was conducted primarily to evaluate occupational radiation dose in industrial radiography during radiographic testing at Balil-Hadida, with the aim of building up baseline data on radiation exposure in the industrial radiography practice in Sudan. Dose measurements during radiographic testing were performed and compared with IAEA reference dose. In this research the doses measured by using hand held radiation survey meter and personal monitoring dosimeter. The results showed that radiation doses ranged between minimum (0.448 mSv/ 3 month) , and maximum (1.838 mSv / 3 month), with an average value (0.778 mSv/ 3 month), and the standard deviation 0.292 for the workers used gamma mat camera. The analysis of data showed that the radiation dose for all radiation worker are receives less than annual limit for exposed workers 20 mSv/ year and compare with other study found that the dose received while body doses ranging from 0.1 to 9.4 mSv/ year, work area design in all the radiography site followed the three standard rules namely putting radiation signs, reducing access to control area and making of boundaries. Thus the accidents arising from design faults not likely to occur at these site. Results suggest that adequate fundamental training of radiation workers in general radiography prior to industrial radiography work will further improve the standard of personnel radiation protection. (Author)

  6. Radiation Testing of Electronics for the CMS Endcap Muon System

    CERN Document Server

    INSPIRE-00070357; Celik, A.; Durkin, L.S.; Gilmore, J.; Haley, J.; Khotilovich, V.; Lakdawala, S.; Liu, J.; Matveev, M.; Padley, B.P.; Roberts, J.; Roe, J.; Safonov, A.; Suarez, I.; Wood, D.; Zawisza, I.

    2013-01-01

    The electronics used in the data readout and triggering system for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) particle accelerator at CERN are exposed to high radiation levels. This radiation can cause permanent damage to the electronic circuitry, as well as temporary effects such as data corruption induced by Single Event Upsets. Once the High Luminosity LHC (HL-LHC) accelerator upgrades are completed it will have five times higher instantaneous luminosity than LHC, allowing for detection of rare physics processes, new particles and interactions. Tests have been performed to determine the effects of radiation on the electronic components to be used for the Endcap Muon electronics project currently being designed for installation in the CMS experiment in 2013. During these tests the digital components on the test boards were operating with active data readout while being irradiated with 55 MeV protons. In reactor tests, components were exposed to 30 years equivalent levels o...

  7. Cone Penetrometer Load Cell Temperature and Radiation Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Follett, Jordan R.

    2013-08-28

    This report summarizes testing activities performed at the Pacific Northwest National Laboratory to verify the cone penetrometer load cell can withstand the tank conditions present in 241-AN-101 and 241-AN-106. The tests demonstrated the load cell device will operate under the elevated temperature and radiation levels expected to be encountered during tank farm deployment of the device.

  8. 2012 ARPA-E Energy Innovation Summit: Fireside Chat with Steven Chu and Bill Gates

    Energy Technology Data Exchange (ETDEWEB)

    Chu, Steven; Gates, Bill; Podesta, John

    2012-02-28

    The third annual ARPA-E Energy Innovation Summit was held in Washington D.C. in February, 2012. The event brought together key players from across the energy ecosystem - researchers, entrepreneurs, investors, corporate executives, and government officials - to share ideas for developing and deploying the next generation of energy technologies. This video captures a session called Fireside Chat that featured Steven Chu, the Secretary of Energy, and Bill Gates, Chairman of Microsoft Corporation. The session is moderated by John Podesta, Chair of the Center for American Progress. Energy Secretary Steven Chu and Microsoft Founder and Chairman Bill Gates exchanged ideas about how small businesses and innovators can overcome the challenges that face many startups.

  9. Test of aerogel as Cherenkov radiator

    CERN Document Server

    Alemi, M; Calvi, M; Matteuzzi, C; Negri, P; Paganoni, M; Liko, D; Neufeld, N; Chesi, Enrico Guido; Joram, C; Séguinot, Jacques; Ypsilantis, Thomas

    2001-01-01

    Two different stacks of aerogel were tested in a pion/proton beam of momentum between 3 and 10 GeV/c. The optical characteristics of the aerogel samples were different: one sample was hygroscopic while the other was hydrophobic. Two HPD tubes were used as photodetectors, and different thicknesses of the stacks were used, in order to determine the photoelectron yield, the Cherenkov angle and its precision. Pion/proton separation has been demonstrated at momenta up to 10 GeV/c.

  10. Nevada Test Site Radiation Protection Program - Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Radiological Control Managers' Council

    2008-06-01

    Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection,' establishes radiation protection standards, limits, and program requirements for protecting individuals from ionizing radiation resulting from the conduct of U.S. Department of Energy (DOE) activities. 10 CFR 835.101(a) mandates that DOE activities be conducted in compliance with a documented Radiation Protection Program (RPP) as approved by DOE. This document promulgates the RPP for the Nevada Test Site (NTS), related (on-site or off-site) U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) operations, and environmental restoration off-site projects. This NTS RPP promulgates the radiation protection standards, limits, and program requirements for occupational exposure to ionizing radiation resulting from NNSA/NSO activities at the NTS and other operational areas as stated in 10 CFR 835.1(a). NNSA/NSO activities (including design, construction, operation, and decommissioning) within the scope of this RPP may result in occupational exposures to radiation or radioactive material. Therefore, a system of control is implemented through specific references to the site-specific NV/YMP RCM. This system of control is intended to ensure that the following criteria are met: (1) occupational exposures are maintained as low as reasonably achievable (ALARA), (2) DOE's limiting values are not exceeded, (3) employees are aware of and are prepared to cope with emergency conditions, and (4) employees are not inadvertently exposed to radiation or radioactive material.

  11. Nevada Test Site Radiation Protection Program - Revision 1

    International Nuclear Information System (INIS)

    Nevada Test Site Radiological Control Managers' Council

    2008-01-01

    Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection,' establishes radiation protection standards, limits, and program requirements for protecting individuals from ionizing radiation resulting from the conduct of U.S. Department of Energy (DOE) activities. 10 CFR 835.101(a) mandates that DOE activities be conducted in compliance with a documented Radiation Protection Program (RPP) as approved by DOE. This document promulgates the RPP for the Nevada Test Site (NTS), related (on-site or off-site) U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) operations, and environmental restoration off-site projects. This NTS RPP promulgates the radiation protection standards, limits, and program requirements for occupational exposure to ionizing radiation resulting from NNSA/NSO activities at the NTS and other operational areas as stated in 10 CFR 835.1(a). NNSA/NSO activities (including design, construction, operation, and decommissioning) within the scope of this RPP may result in occupational exposures to radiation or radioactive material. Therefore, a system of control is implemented through specific references to the site-specific NV/YMP RCM. This system of control is intended to ensure that the following criteria are met: (1) occupational exposures are maintained as low as reasonably achievable (ALARA), (2) DOE's limiting values are not exceeded, (3) employees are aware of and are prepared to cope with emergency conditions, and (4) employees are not inadvertently exposed to radiation or radioactive material

  12. Implementation and testing of a multivariate inverse radiation transport solver

    International Nuclear Information System (INIS)

    Mattingly, John; Mitchell, Dean J.

    2012-01-01

    Detection, identification, and characterization of special nuclear materials (SNM) all face the same basic challenge: to varying degrees, each must infer the presence, composition, and configuration of the SNM by analyzing a set of measured radiation signatures. Solutions to this problem implement inverse radiation transport methods. Given a set of measured radiation signatures, inverse radiation transport estimates properties of the source terms and transport media that are consistent with those signatures. This paper describes one implementation of a multivariate inverse radiation transport solver. The solver simultaneously analyzes gamma spectrometry and neutron multiplicity measurements to fit a one-dimensional radiation transport model with variable layer thicknesses using nonlinear regression. The solver's essential components are described, and its performance is illustrated by application to benchmark experiments conducted with plutonium metal. - Highlights: ► Inverse problems, specifically applied to identifying and characterizing radiation sources . ► Radiation transport. ► Analysis of gamma spectroscopy and neutron multiplicity counting measurements. ► Experimental testing of the inverse solver against measurements of plutonium.

  13. Prevention de la transmission mere enfant du VIH/SIDA au Chu de ...

    African Journals Online (AJOL)

    La transmission Mère Enfant du VIH/SIDA est le mode de contamination essentielle des enfants dans les pays en développement. Objectif : Evaluer les résultats de la Prévention de la Transmission Mère-Enfant (PTME) du VIH au CHU-Kara. Méthode: Il s'est agi d'une étude rétrospective descriptive de juillet 2005 à Juin ...

  14. Rupture traumatique du diaphragme au CHU Gabriel Touré de ...

    African Journals Online (AJOL)

    Rupture traumatique du diaphragme au CHU Gabriel Touré de Bamako, Mali. B T Dembélé, A Togo, A Traoré, Y Sidibé, M Konaté, A A Traoré, A Bah, T Koné, I Tounkara, L Kanté, I Diakité, B Karembé, A Koné, M.I Mangane, G Diallo ...

  15. Six-Tube Freezable Radiator Testing and Model Correlation

    Science.gov (United States)

    Lilibridge, Sean T.; Navarro, Moses

    2012-01-01

    Freezable Radiators offer an attractive solution to the issue of thermal control system scalability. As thermal environments change, a freezable radiator will effectively scale the total heat rejection it is capable of as a function of the thermal environment and flow rate through the radiator. Scalable thermal control systems are a critical technology for spacecraft that will endure missions with widely varying thermal requirements. These changing requirements are a result of the spacecraft?s surroundings and because of different thermal loads rejected during different mission phases. However, freezing and thawing (recov ering) a freezable radiator is a process that has historically proven very difficult to predict through modeling, resulting in highly inaccurate predictions of recovery time. These predictions are a critical step in gaining the capability to quickly design and produce optimized freezable radiators for a range of mission requirements. This paper builds upon previous efforts made to correlate a Thermal Desktop(TM) model with empirical testing data from two test articles, with additional model modifications and empirical data from a sub-component radiator for a full scale design. Two working fluids were tested: MultiTherm WB-58 and a 50-50 mixture of DI water and Amsoil ANT.

  16. Radiation testing of electronics for the CMS endcap muon system

    Energy Technology Data Exchange (ETDEWEB)

    Bylsma, B. [Ohio State University (United States); Cady, D.; Celik, A. [Texas A and M University, College Station, TX 77843 (United States); Durkin, L.S. [Ohio State University (United States); Gilmore, J., E-mail: gilmore@tamu.edu [Texas A and M University, College Station, TX 77843 (United States); Haley, J. [Northeastern University (United States); Khotilovich, V.; Lakdawala, S. [Texas A and M University, College Station, TX 77843 (United States); Liu, J.; Matveev, M.; Padley, B.P.; Roberts, J. [Rice University (United States); Roe, J.; Safonov, A.; Suarez, I. [Texas A and M University, College Station, TX 77843 (United States); Wood, D. [Northeastern University (United States); Zawisza, I. [Texas A and M University, College Station, TX 77843 (United States)

    2013-01-11

    The electronics used in the data readout and triggering system for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) particle accelerator at CERN are exposed to high radiation levels. This radiation can cause permanent damage to the electronic circuitry, as well as temporary effects such as data corruption induced by Single Event Upsets. Once the High Luminosity LHC (HL-LHC) accelerator upgrades are completed it will have five times higher instantaneous luminosity than LHC, allowing for detection of rare physics processes, new particles and interactions. Tests have been performed to determine the effects of radiation on the electronic components to be used for the Endcap Muon electronics project currently being designed for installation in the CMS experiment in 2013. During these tests the digital components on the test boards were operating with active data readout while being irradiated with 55 MeV protons. In reactor tests, components were exposed to 30 years equivalent levels of neutron radiation expected at the HL-LHC. The highest total ionizing dose (TID) for the muon system is expected at the innermost portion of the CMS detector, with 8900 rad over 10 years. Our results show that Commercial Off-The-Shelf (COTS) components selected for the new electronics will operate reliably in the CMS radiation environment.

  17. Radiation testing of electronics for the CMS endcap muon system

    Science.gov (United States)

    Bylsma, B.; Cady, D.; Celik, A.; Durkin, L. S.; Gilmore, J.; Haley, J.; Khotilovich, V.; Lakdawala, S.; Liu, J.; Matveev, M.; Padley, B. P.; Roberts, J.; Roe, J.; Safonov, A.; Suarez, I.; Wood, D.; Zawisza, I.

    2013-01-01

    The electronics used in the data readout and triggering system for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) particle accelerator at CERN are exposed to high radiation levels. This radiation can cause permanent damage to the electronic circuitry, as well as temporary effects such as data corruption induced by Single Event Upsets. Once the High Luminosity LHC (HL-LHC) accelerator upgrades are completed it will have five times higher instantaneous luminosity than LHC, allowing for detection of rare physics processes, new particles and interactions. Tests have been performed to determine the effects of radiation on the electronic components to be used for the Endcap Muon electronics project currently being designed for installation in the CMS experiment in 2013. During these tests the digital components on the test boards were operating with active data readout while being irradiated with 55 MeV protons. In reactor tests, components were exposed to 30 years equivalent levels of neutron radiation expected at the HL-LHC. The highest total ionizing dose (TID) for the muon system is expected at the innermost portion of the CMS detector, with 8900 rad over 10 years. Our results show that Commercial Off-The-Shelf (COTS) components selected for the new electronics will operate reliably in the CMS radiation environment.

  18. Compilation of radiation damage test data. Pt. 3

    International Nuclear Information System (INIS)

    Beynel, P.; Maier, P.; Schoenbacher, H.

    1982-01-01

    This handbook gives the results of radiation damage tests on various engineering materials and components intended for installation in radiation areas of the CERN high-energy particle accelerators. It complements two previous volumes covering organic cable-insulating materials and thermoplastic and thermosetting resins. The irradiation have been carried out at various radiation sources and the results of the different tests are reported, sometimes illustrated by tables and graphs to show the variation of the measured property with absorbed radiation dose. For each entry, an appreciation of the radiation resistance is given, based on measurement data, indicating the range of damage (moderate to severe) for doses from 10 to 10 8 Gy. Also included are tables, selected from published reports, of general relative radiation effects for several groups of materials, to which there are systematic cross-references in the alphabetical part. This third and last volume contains cross-references to all the materials presented up to now, so that it can be used as a guide to the three volumes. (orig.)

  19. Radiation Resistance Test of Wireless Sensor Node and the Radiation Shielding Calculation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Liqan; Sur, Bhaskar [Atomic Energy of Canada Limited, Ontario (Canada); Wang, Quan [University of Western Ontario, Ontario (Canada); Deng, Changjian [The University of Electronic Science and Technology, Chengdu (China); Chen, Dongyi; Jiang, Jin [Applied Physics Branch, Ontario (Korea, Republic of)

    2014-08-15

    A wireless sensor network (WSN) is being developed for nuclear power plants. Amongst others, ionizing radiation resistance is one essential requirement for WSN to be successful. This paper documents the work done in Chalk River Laboratories of Atomic Energy of Canada Limited (AECL) to test the resistance to neutron and gamma radiation of some WSN nodes. The recorded dose limit that the nodes can withstand before being damaged by the radiation is compared with the radiation environment inside a typical CANDU (CANada Deuterium Uranium) power plant reactor building. Shielding effects of polyethylene, cadmium and lead to neutron and gamma radiations are also analyzed using MCNP simulation. The shielding calculation can be a reference for the node case design when high dose rate or accidental condition (like Fukushima) is to be considered.

  20. Current clinical trials testing combinations of immunotherapy and radiation.

    Science.gov (United States)

    Crittenden, Marka; Kohrt, Holbrook; Levy, Ronald; Jones, Jennifer; Camphausen, Kevin; Dicker, Adam; Demaria, Sandra; Formenti, Silvia

    2015-01-01

    Preclinical evidence of successful combinations of ionizing radiation with immunotherapy has inspired testing the translation of these results to the clinic. Interestingly, the preclinical work has consistently predicted the responses encountered in clinical trials. The first example came from a proof-of-principle trial started in 2001 that tested the concept that growth factors acting on antigen-presenting cells improve presentation of tumor antigens released by radiation and induce an abscopal effect. Granulocyte-macrophage colony-stimulating factor was administered during radiotherapy to a metastatic site in patients with metastatic solid tumors to translate evidence obtained in a murine model of syngeneic mammary carcinoma treated with cytokine FLT-3L and radiation. Subsequent clinical availability of vaccines and immune checkpoint inhibitors has triggered a wave of enthusiasm for testing them in combination with radiotherapy. Examples of ongoing clinical trials are described in this report. Importantly, most of these trials include careful immune monitoring of the patients enrolled and will generate important data about the proimmunogenic effects of radiation in combination with a variety of immune modulators, in different disease settings. Results of these studies are building a platform of evidence for radiotherapy as an adjuvant to immunotherapy and encourage the growth of this novel field of radiation oncology. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Lap Shear Testing of Candidate Radiator Panel Adhesives

    Science.gov (United States)

    Ellis, David; Briggs, Maxwell; McGowan, Randy

    2013-01-01

    During testing of a subscale radiator section used to develop manufacturing techniques for a full-scale radiator panel, the adhesive bonds between the titanium heat pipes and the aluminum face sheets failed during installation and operation. Analysis revealed that the thermal expansion mismatch between the two metals resulted in relatively large shear stresses being developed even when operating the radiator at moderate temperatures. Lap shear testing of the adhesive used in the original joints demonstrated that the two-part epoxy adhesive fell far short of the strength required. A literature review resulted in several candidate adhesives being selected for lap shear joint testing at room temperature and 398 K, the nominal radiator operating temperature. The results showed that two-part epoxies cured at room and elevated temperatures generally did not perform well. Epoxy film adhesives cured at elevated temperatures, on the other hand, did very well with most being sufficiently strong to cause yielding in the titanium sheet used for the joints. The use of an epoxy primer generally improved the strength of the joint. Based upon these results, a new adhesive was selected for the second subscale radiator section.

  2. Design and testing of an innovative solar radiation measurement device

    International Nuclear Information System (INIS)

    Badran, Omar; Al-Salaymeh, Ahmed; El-Tous, Yousif; Abdala, Wasfi

    2010-01-01

    After review of studies conducted on the solar radiation measuring systems, a new innovative instrument that would help in measuring the accurate solar radiation on horizontal surfaces has been designed and tested. An advanced instrument with ease of use and high precision that would enable the user to take the readings in terms of solar intensity (W/m 2 ) has been tested. Also, the innovative instrument can record instantaneous readings of the solar intensities as well as the averages value of the solar radiation flux during certain periods of time. The instrument based in its design on being programmed by programmable interfacing controller (PIC). Furthermore, the power supply circuit is fed by the solar energy cells and does not need an external power source.

  3. The feasibility of 10 keV X-ray as radiation source in total dose response radiation test

    International Nuclear Information System (INIS)

    Li Ruoyu; Li Bin; Luo Hongwei; Shi Qian

    2005-01-01

    The standard radiation source utilized in traditional total dose response radiation test is 60 Co, which is environment-threatening. X-rays, as a new radiation source, has the advantages such as safety, precise control of dose rate, strong intensity, possibility of wafer-level test or even on-line test, which greatly reduce cost for package, test and transportation. This paper discussed the feasibility of X-rays replacing 60 Co as the radiation source, based on the radiation mechanism and the effects of radiation on gate oxide. (authors)

  4. ANOLE Portable Radiation Detection System Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Hodge, Chris A.

    2007-01-01

    Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also offered manufacturers the opportunity to submit their equipment for independent operationally relevant testing to subsequently improve their detector performance. This paper will present the design, execution, and methodologies of the DHS Anole portable radiation detection system test campaign

  5. Radiation Isotope Identification Device (RIIDs) Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Christopher Hodge, Raymond Keegan

    2007-01-01

    Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also offered manufacturers the opportunity to submit their equipment for independent operationally relevant testing to subsequently improve their detector performance. This paper will present the design, execution, and methodologies of the DHS Anole portable radiation detection system test campaign

  6. Radiation Testing of PICA at the Solar Power Tower

    Science.gov (United States)

    White, Susan

    2010-01-01

    Sandia National Laboratory's Solar Power Tower was used to irradiate specimens of Phenolic Impregnated Carbon Ablator (PICA), in order to evaluate whether this thermal protection system material responded differently to potential shock layer radiative heating than to convective heating. Tests were run at 50, 100 and 150 Watts per square centimeter levels of concentrated solar radiation. Experimental results are presented both from spectral measurements on 1- 10 mm thick specimens of PICA, as well as from in-depth temperature measurements on instrumented thicker test specimens. Both spectral measurements and measured in-depth temperature profiles showed that, although it is a porous, low-density material, PICA does not exhibit problematic transparency to the tested high levels of NIR radiation, for all pragmatic cm-to-inch scale thicknesses. PICA acted as a surface absorber to efficiently absorb the incident visible and near infrared incident radiation in the top 2 millimeter layer in the Solar Power Tower tests up to 150 Watts per square centimeter.

  7. Radiation Requirements and Testing of Cryogenic Thermometers for the Ilc

    Science.gov (United States)

    Barnett, T.; Filippov, Yu. P.; Filippova, E. Yu.; Mokhov, N. V.; Nakao, N.; Klebaner, A. L.; Korenev, S. A.; Theilacker, J. C.; Trenikhina, J.; Vaziri, K.

    2008-03-01

    Large quantity of cryogenic temperature sensors will be used for operation of the International Linear Collider (ILC). Most of them will be subject to high radiation doses during the accelerator lifetime. Understanding of particle energy spectra, accumulated radiation dose in thermometers and its impact on performance are vital in establishing technical specification of cryogenic thermometry for the ILC. Realistic MARS15 computer simulations were performed to understand the ILC radiation environment. Simulation results were used to establish radiation dose requirements for commercially available cryogenic thermometers. Two types of thermometers, Cernox® and TVO, were calibrated prior to irradiation using different technique. The sensors were subjected then to up to 200 kGy electron beam irradiation with kinetic energy of 5 MeV, a representative of the situation at the ILC operation. A post-irradiation behavior of the sensors was studied. The paper describes the MARS15 model, simulation results, cryogenic test set-up, irradiation tests, and cryogenic test results.

  8. Radiation requirements and testing of cryogenic thermometers for the ILC

    International Nuclear Information System (INIS)

    Barnett, T.; Filippov, Yu.P.; Mokhov, N.V.; Nakao, N.; Klebaner, A.L.; Korenev, S.A.; Theilacker, J.C.; Trenikhina, J.; Vaziri, K.

    2007-01-01

    Large quantity of cryogenic temperature sensors will be used for operation of the International Linear Collider (ILC). Most of them will be subject to high radiation doses during the accelerator lifetime. Understanding of particle energy spectra, accumulated radiation dose in thermometers and its impact on performance are vital in establishing technical specification of cryogenic thermometry for the ILC. Realistic MARS15 computer simulations were performed to understand the ILC radiation environment. Simulation results were used to establish radiation dose requirements for commercially available cryogenic thermometers. Two types of thermometers, Cernox(reg s ign) and TVO, were calibrated prior to irradiation using different technique. The sensors were subjected then to up to 200 kGy electron beam irradiation with kinetic energy of 5 MeV, a representative of the situation at the ILC operation. A post-irradiation behavior of the sensors was studied. The paper describes the MARS15 model, simulation results, cryogenic test set-up, irradiation tests, and cryogenic test results

  9. Personal Radiation Detector Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Chris A. Hodge, Ding Yuan, Raymond P. Keegan, Michael A. Krstich

    2007-01-01

    Following the success of the Anole test of portable detection system, the U.S. Department of Homeland Security (DHS) Domestic Nuclear Detection Office organized a test and evaluation campaign for personal radiation detectors (PRDs), also known as 'Pagers'. This test, 'Bobcat', was conducted from July 17 to August 8, 2006, at the Nevada Test Site. The Bobcat test was designed to evaluate the performance of PRDs under various operational scenarios, such as pedestrian surveying, mobile surveying, cargo container screening, and pedestrian chokepoint monitoring. Under these testing scenarios, many operational characteristics of the PRDs, such as gamma and neutron sensitivities, positive detection and false alarm rates, response delay times, minimum detectable activities, and source localization errors, were analyzed. This paper will present the design, execution, and methodologies used to test this equipment for the DHS

  10. General gamma-radiation test of TGC detectors

    CERN Document Server

    Smakhtin, V P

    2004-01-01

    The TGC detectors are expected to provide the Muon trigger for the ATLAS detector in the forward region of the ATLAS Muon Spectrometer. The TGC detectors have to provide a trigger signal within 25 ns of the LHC accelerator bunch spacing, with an efficiency exceeding 95%, while exposed to an effective)photon and neutron background ranging from 30 to 150 Hz/cm/sup 2/. In order to test TGC detectors in high rate environment every detector was irradiated at 2500 Cu Co-60 source in Radiation Facility of Weizmann Institute of Science at nominal operating voltage and at photon rate several times above the expected background. This radiation test was succeeded in diagnostics of the hot spots inside detectors. The present publication refers to the test results of 800 TGC detectors produced in the Weizmann Institute of Science. (1 refs).

  11. Operation of radiation monitoring system in radwaste form test facility

    International Nuclear Information System (INIS)

    Ryu, Young Gerl; Kim, Ki Hong; Lee, Jae Won; Kwac, Koung Kil

    1998-08-01

    RWFTF (RadWaste Form Test Facility) must have a secure radiation monitoring system (RMS) because of having a hot-cell capable of handling high radioactive materials. And then in controlled radiation zone, which is hot-cell and its maintenance and operation / control room, area dose rate, radioactivities in air-bone particulates and stack, and surface contamination are monitored continuously. For the effective management such as higher utilization, maintenance and repair, the status of this radiation monitoring system, the operation and characteristics of all kinds of detectors and other parts of composing this system, and signal treatment and its evaluation were described in this technical report. And to obtain the accuracy detection results and its higher confidence level, the procedure such as maintenance, functional check and system calibration were established and appended to help the operation of RMS. (author). 6 tabs., 30 figs

  12. Redatuming borehole-to-surface electromagnetic data using Stratton-Chu integral transforms

    DEFF Research Database (Denmark)

    Zhdanov, Michael; Cai, Hongzhu

    2012-01-01

    We present a new method of analyzing borehole-to-surface electromagnetic (BSEM) survey data based on redatuming of the observed data from receivers distributed over the surface of the earth onto virtual receivers located within the subsurface. The virtual receivers can be placed close to the target...... of interest, such as just above a hydrocarbon reservoir, which increases the sensitivity of the EM data to the target. The method is based on the principles of downward analytical continuation of EM fields. We use Stratton-Chu type integral transforms to calculate the EM fields at the virtual receivers. Model...

  13. Matrilineal Marriage in Tibetan Areas In Western Sìchuān Province (English translation)

    OpenAIRE

    Feng Min

    2010-01-01

    The marriage and family organization of the Zhaba 扎巴 people in Western Sìchuān 四川 Province is similar to that practiced by the Nàxi Mósūo 纳西摩梭 during the 1960s. The Zhaba 扎坝2 Region is another matrilineal culture region in addition to the Lúgū 泸沽 Region in Yúnnán 云南 Province. The area has only recently begun modernizing because of its isolation. 'Visiting marriages' and matrilineal family organization continue to play an important role in Zhaba culture. This research contributes new material ...

  14. Algae as test organisms of harmful effects of various radiations

    International Nuclear Information System (INIS)

    Necas, J.

    1989-01-01

    The report describes a complex biotest in which algae serve as the test organisms and where a variety of algal characteristics are employed as indicators of the effects of harmful radiations on the cultures and single organisms. Rules for a successful choice of a suitable algal organism are discussed and the preparation of the latter for the test as well as the growth and morphogenic tests and some physiological responses of algae to harmful radiation are described. The survival and lethality are related to the interpretation of the test results particularly from the physiological and genetic points of view. The complex biotest concerns not only toxic but also mutagenic effects of the factors tested. Some easily detectable mutations in algae are mentioned and their spectra are recommended. The stability of the mutations and the possibility of their delayed manifestation are considered. The possibility of occurrence of teratogenic effects is also dealt with and the negative role of phenocopies in the correct evaluation of the mutation effects is mentioned. Advice for the breeding and laboratory maintenance of suitable algal strains for the biotest is given. Practical use of the biotest is demonstrated on the results of a test using modified samples of waste water from uranium industries. It is recommended that biotests confined to the evaluation of single characteristics of the test organism be replaced by this complex biotest whose results can be interpreted more extensively and exhibit a higher reliability. (author). 268 refs., 1 tab., 9 figs

  15. Radiation effects testing at the 88-Inch Cyclotron at LBNL

    International Nuclear Information System (INIS)

    McMahan, Margaret A.; Koga, Rokotura

    2002-01-01

    The effects of ionizing particles on sensitive microelectronics is an important component of the design of systems as diverse as satellites and space probes, detectors for high energy physics experiments and even internet server farms. Understanding the effects of radiation on human cells is an equally important endeavor directed towards future manned missions in space and towards cancer therapy. At the 88-Inch Cyclotron at the Berkeley Laboratory, facilities are available for radiation effects testing (RET) with heavy ions and with protons. The techniques for doing these measurements and the advantages of using a cyclotron will be discussed, and the Cyclotron facilities will be compared with other facilities worldwide. RET of the same part at several facilities of varying beam energy can provide tests of the simple models used in this field and elucidate the relative importance of atomic and nuclear effects. The results and implications of such measurements will be discussed

  16. Laser system for testing radiation imaging detector circuits

    Science.gov (United States)

    Zubrzycka, Weronika; Kasinski, Krzysztof

    2015-09-01

    Performance and functionality of radiation imaging detector circuits in charge and position measurement systems need to meet tight requirements. It is therefore necessary to thoroughly test sensors as well as read-out electronics. The major disadvantages of using radioactive sources or particle beams for testing are high financial expenses and limited accessibility. As an alternative short pulses of well-focused laser beam are often used for preliminary tests. There are number of laser-based devices available on the market, but very often their applicability in this field is limited. This paper describes concept, design and validation of laser system for testing silicon sensor based radiation imaging detector circuits. The emphasis is put on keeping overall costs low while achieving all required goals: mobility, flexible parameters, remote control and possibility of carrying out automated tests. The main part of the developed device is an optical pick-up unit (OPU) used in optical disc drives. The hardware includes FPGA-controlled circuits for laser positioning in 2 dimensions (horizontal and vertical), precision timing (frequency and number) and amplitude (diode current) of short ns-scale (3.2 ns) light pulses. The system is controlled via USB interface by a dedicated LabVIEW-based application enabling full manual or semi-automated test procedures.

  17. Successful beam tests for ALICE Transition Radiation Detector

    CERN Multimedia

    2002-01-01

    Another round of beam tests of prototypes for the Transition Radiation Detector (TRD) for ALICE has been completed and there are already some good results. Mass production of the components of the detector will start early next year.   Top view of the setup for the Transition Radiation Detector prototype tests at CERN.On the left, can be seen the full-scale TRD prototype together with four smaller versions. These are busy days for the TRD (Transition Radiation Detector) team of ALICE. Twenty people - mainly from Germany, but also from Russia and Japan - were working hard during the beam tests this autumn at CERN to assess the performance of their detector prototypes. Analysis of the data shows that the TRD can achieve the desired physics goal even for the highest conceivable multiplicities in lead-lead collisions at the LHC. In its final configuration in the ALICE experiment, the TRD will greatly help in identifying high-momentum electrons, which are 'needles in a haystack' that consists mostly of...

  18. Compilation of radiation damage test data cable insulating materials

    CERN Document Server

    Schönbacher, H; CERN. Geneva

    1979-01-01

    This report summarizes radiation damage test data on commercially available organic cable insulation and jacket materials: ethylene- propylene rubber, Hypalon, neoprene rubber, polyethylene, polyurethane, polyvinylchloride, silicone rubber, etc. The materials have been irradiated in a nuclear reactor to integrated absorbed doses from 5*10/sup 5/ to 5*10/sup 6/ Gy. Mechanical properties, e.g. tensile strength, elongation at break, and hardness, have been tested on irradiated and non-irradiated samples. The results are presented in the form of tables and graphs, to show the effect of the absorbed dose on the measured properties. (13 refs).

  19. Synchrotron radiation losses in Engineering Test Reactors (ETRs)

    International Nuclear Information System (INIS)

    Uckan, N.A.

    1987-11-01

    In next-generation Engineering Test Reactors (ETRs), one major objective is envisioned to be a long-pulse or steady-state burn using noninductive current drive. At the high temperatures needed for efficient current drive, synchrotron radiation could represent a large power loss, especially if wall reflectivity (R) is very low. Many INTOR-class ETR designs [Fusion Engineering Reactor (FER), Next European Torus (NET), OTR, Tokamak Ignition/Burn Engineering Reactor (TIBER), etc.] call for carbon-covered surfaces for which wall reflectivity is uncertain. Global radiation losses are estimated for these devices using empirical expressions given by Trubnikov (and others). Various operating scenarios are evaluated under the assumption that the plasma performance is limited by either the density limit (typical of the ignition phase) or the beta limit (typical of the current drive phase). For a case with ≥90% wall reflectivity, synchrotron radiation is not a significant contribution to the overall energy balance (the ratio of synchrotron to alpha power is less than 10 to 20%, even at ∼ 30 keV) and thus should not adversely alter performance in these devices. In extreme cases with 0% wall reflectivity, the ratio of synchrotron radiation to alpha power may approach 30 to 60% (depending on the device and limiting operating scenario), adversely affecting the performance characteristics. 12 refs., 7 tabs

  20. Confirmation of soil radiation damping from test versus analysis

    International Nuclear Information System (INIS)

    Eidinger, J.M.; Mukhim, G.S.; Desmond, T.P.

    1987-01-01

    The work was performed to demonstrate that soil-structure interaction effects for nuclear plant structures can be accurately (and conservatively) predicted using the finite element or soil spring methods of soil-structure interaction analysis. Further, the work was done to investigate the relative importance of soil radiation versus soil material damping in the total soil damping analytical treatment. The analytical work was benchmarked with forced vibration tests of a concrete circular slab resting on the soil surface. The applied loading was in the form of a suddenly applied pulse load, or snapback. The measured responses of the slap represent the free vibration of the slab after the pulse load has been applied. This simplifies the interpretation of soil damping, by the use of the logarithmic decay formulation. To make comparisons with the test results, the damping data calculated from the analytical models is also based on the logarithmic decay formulation. An attempt is made to differentiate the observed damped behavior of the concrete slab as being caused by soil radiation versus soil material damping. It is concluded that both the traditional soil radiation and material damping analytical simplifications are validated by the observed responses. It is concluded that arbitrary 'conservative' assumptions traditionally made in nuclear plant soil-structure interaction analyses are indeed arbitrary, and not born out by physical evidence. The amount of conservatism introduced by limiting total soil damping to values like 5% to 10% can be large. For the test slab sizes investigated, total soil damping is about 25%. For full size nuclear plant foundations, total soil damping is commonly in the 35% to 70% range. The authors suggest that full soil damping values (the combined radiation and material damping) should be used in the design, backfit and margin assessment of nuclear plants. (orig./HP)

  1. Epidémiologie de l'infection urinaire chez l'enfant au CHU-Campus ...

    African Journals Online (AJOL)

    Titre : Epidémiologie de l'infection urinaire chez l'enfant au CHU-Campus de Lomé. Objectif : Evaluer la prévalence et étudier l'épidémiologie des infections urinaires. Méthodologie : Il s'agit d'une étude prospective qui s'est déroulée du 1er janvier au 31décembre 2009, dans le service de pédiatrie du CHU-Campus de ...

  2. Characterization of radiation effects in 65 nm digital circuits with the DRAD digital radiation test chip

    International Nuclear Information System (INIS)

    Casas, L.M. Jara; Ceresa, D.; Kulis, S.; Christiansen, J.; Francisco, R.; Miryala, S.; Gnani, D.

    2017-01-01

    A Digital RADiation (DRAD) test chip has been specifically designed to study the impact of Total Ionizing Dose (TID) (<1 Grad) and Single Event Upset (SEU) on digital logic gates in a 65 nm CMOS technology. Nine different versions of standard cell libraries are studied in this chip, basically differing in the device dimensions, V t flavor and layout of the device. Each library has eighteen test structures specifically designed to characterize delay degradation and power consumption of the standard cells. For SEU study, a dedicated test structure based on a shift register is designed for each library. TID results up to 500 Mrad are reported.

  3. Preliminary analysis of accelerated space flight ionizing radiation testing

    Science.gov (United States)

    Wilson, J. W.; Stock, L. V.; Carter, D. J.; Chang, C. K.

    1982-01-01

    A preliminary analysis shows that radiation dose equivalent to 30 years in the geosynchronous environment can be accumulated in a typical composite material exposed to space for 2 years or less onboard a spacecraft orbiting from perigee of 300 km out to the peak of the inner electron belt (approximately 2750 km). Future work to determine spacecraft orbits better tailored to materials accelerated testing is indicated. It is predicted that a range of 10 to the 9th power to 10 to the 10th power rads would be accumulated in 3-6 mil thick epoxy/graphite exposed by a test spacecraft orbiting in the inner electron belt. This dose is equivalent to the accumulated dose that this material would be expected to have after 30 years in a geosynchronous orbit. It is anticipated that material specimens would be brought back to Earth after 2 years in the radiation environment so that space radiation effects on materials could be analyzed by laboratory methods.

  4. Radiation exposure of inhabitants around Semipalatinsk nuclear weapon test site

    International Nuclear Information System (INIS)

    Takada, Jun; Hoshi, Masaharu

    1997-01-01

    This paper described and reviewed the data reported by Russia and Kazakhstan and authors' studies on the exposed doses as follows. History of nuclear explosion tests in Semipalatinsk: From 1949 to 1989 in old Russia, 459 explosion tests involving 26 on the ground, 87 in the air and 346 in underground were performed, of which TNT equivalence was 0.6 Mt, 6 Mt and 11 Mt, respectively. A mystery in the reports of radiation doses by Russia and Kazakhstan. Present status of the regions after the end of nuclear weapon tests: Environment radiation doses in μSv/h in following regions were 0.06 in Mostik, 0.1 in Dolon and Semipalatinsk, 0.07 in Izvyestka and Znamenka, 0.08 in Tchagan and 21 in Atomic Lake. Evaluation of external exposure dose of the living regions with thermoluminescence method: External exposure dose was estimated to be about 90 cGy in a certain village and 40 cGy in Semipalatinsk which being 150 km far from the test site. (K.H.)

  5. Radiation Tests of Single Photon Avalanche Diode for Space Applications

    Science.gov (United States)

    Moscatelli, Francesco; Marisaldi, Martino; MacCagnani, Piera; Labanti, Claudio; Fuschino, Fabio; Prest, Michela; Berra, Alessandro; Bolognini, Davide; Ghioni, Massimo; Rech, Ivan; hide

    2013-01-01

    Single photon avalanche diodes (SPADs) have been recently studied as photodetectors for applications in space missions. In this presentation we report the results of radiation hardness test on large area SPAD (actual results refer to SPADs having 500 micron diameter). Dark counts rate as low as few kHz at -10 degC has been obtained for the 500 micron devices, before irradiation. We performed bulk damage and total dose radiation tests with protons and gamma-rays in order to evaluate their radiation hardness properties and their suitability for application in a Low Earth Orbit (LEO) space mission. With this aim SPAD devices have been irradiated using up to 20 krad total dose with gamma-rays and 5 krad with protons. The test performed show that large area SPADs are very sensitive to proton doses as low as 2×10(exp 8) (1 MeV eq) n/cm2 with a significant increase in dark counts rate (DCR) as well as in the manifestation of the "random telegraph signal" effect. Annealing studies at room temperature (RT) and at 80 degC have been carried out, showing a high decrease of DCR after 24-48 h at RT. Lower protons doses in the range 1-10×10(exp 7) (1 MeV eq) n/cm(exp 2) result in a lower increase of DCR suggesting that the large-area SPADs tested in this study are well suitable for application in low-inclination LEO, particularly useful for gamma-ray astrophysics.

  6. IVVS actuating system compatibility test to ITER gamma radiation conditions

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Paolo, E-mail: paolo.rossi@enea.it [Associazione EURATOM-ENEA sulla Fusione, 45 Via Enrico Fermi, 00044 Frascati, Rome (Italy); Collibus, M. Ferri de; Florean, M.; Monti, C.; Mugnaini, G.; Neri, C.; Pillon, M.; Pollastrone, F. [Associazione EURATOM-ENEA sulla Fusione, 45 Via Enrico Fermi, 00044 Frascati, Rome (Italy); Baccaro, S.; Piegari, A. [ENEA CR Casaccia, 301 Via Anguillarese, 00123 Santa Maria di Galeria, Rome (Italy); Damiani, C.; Dubus, G. [Fusion For Energy c/Josep Pla, n° 2 Torres Diagonal Litoral, 08019 Barcelona (Spain)

    2013-10-15

    Highlights: • ENEA developed and tested a prototype of a laser In Vessel Viewing and ranging System (IVVS) for ITER. • One piezo-motor prototype has been tested on the ENEA Calliope gamma irradiation facility to verify its compatibility to ITER gamma radiation conditions. • After a total dose of more than 4 MGy the piezo-motor maintained almost the same working parameters monitored before test without any evident and significant degradation of functionality. • After the full gamma irradiation test, the same piezo-motor assembly will be tested with 14 MeV neutrons irradiation using ENEA FNG facility. -- Abstract: The In Vessel Viewing System (IVVS) is a fundamental remote handling equipment, which will be used to make a survey of the status of the blanket first wall and divertor plasma facing components. A design and testing activity is ongoing, in the framework of a Fusion for Energy (F4E) grant agreement, to make the IVVS probe design compatible with ITER operating conditions and in particular, but not only, with attention to neutrons and gammas fluxes and both space constraints and interfaces. The paper describes the testing activity performed on the customized piezoelectric motors and the main components of the actuating system of the IVVS probe with reference to ITER gamma radiation conditions. In particular the test is performed on the piezoelectric motor, optical encoder and small scale optical samples .The test is carried out on the ENEA Calliope gamma irradiation facility at ITER relevant gamma fields at rate of about 2.5 kGy/h and doses of 4 MGy. The paper reports in detail the setup arrangement of the test campaign in order to verify significant working capability of the IVVS actuating components and the results are shown in terms of functional performances and parameters. The overall test campaign on IVVS actuating system will be completed on other ENEA testing facilities in order to verify compatibility to Magnetic field, neutrons and thermal

  7. IVVS actuating system compatibility test to ITER gamma radiation conditions

    International Nuclear Information System (INIS)

    Rossi, Paolo; Collibus, M. Ferri de; Florean, M.; Monti, C.; Mugnaini, G.; Neri, C.; Pillon, M.; Pollastrone, F.; Baccaro, S.; Piegari, A.; Damiani, C.; Dubus, G.

    2013-01-01

    Highlights: • ENEA developed and tested a prototype of a laser In Vessel Viewing and ranging System (IVVS) for ITER. • One piezo-motor prototype has been tested on the ENEA Calliope gamma irradiation facility to verify its compatibility to ITER gamma radiation conditions. • After a total dose of more than 4 MGy the piezo-motor maintained almost the same working parameters monitored before test without any evident and significant degradation of functionality. • After the full gamma irradiation test, the same piezo-motor assembly will be tested with 14 MeV neutrons irradiation using ENEA FNG facility. -- Abstract: The In Vessel Viewing System (IVVS) is a fundamental remote handling equipment, which will be used to make a survey of the status of the blanket first wall and divertor plasma facing components. A design and testing activity is ongoing, in the framework of a Fusion for Energy (F4E) grant agreement, to make the IVVS probe design compatible with ITER operating conditions and in particular, but not only, with attention to neutrons and gammas fluxes and both space constraints and interfaces. The paper describes the testing activity performed on the customized piezoelectric motors and the main components of the actuating system of the IVVS probe with reference to ITER gamma radiation conditions. In particular the test is performed on the piezoelectric motor, optical encoder and small scale optical samples .The test is carried out on the ENEA Calliope gamma irradiation facility at ITER relevant gamma fields at rate of about 2.5 kGy/h and doses of 4 MGy. The paper reports in detail the setup arrangement of the test campaign in order to verify significant working capability of the IVVS actuating components and the results are shown in terms of functional performances and parameters. The overall test campaign on IVVS actuating system will be completed on other ENEA testing facilities in order to verify compatibility to Magnetic field, neutrons and thermal

  8. Follow-up of radiopharmaceuticals out of globally harmonized system (G.H.S.) at the C.H.U. of Grenoble; Suivi des medicaments radiopharmaceutiques hors GHS au CHU de Grenoble

    Energy Technology Data Exchange (ETDEWEB)

    Fabien, L.; Desruet, M.D.; Chauchet, X.; Foroni, L. [Radiopharmacie, pole de pharmacie, CHU de Grenoble, (France); Bourre, J.C.; Calizzano, A.; Crepin, C.; Vuillez, J.P. [service de medecine nucleaire, CHU de Grenoble, (France)

    2009-05-15

    The improvement and the secure of the radiopharmaceutical circuit in the service of nuclear medicine of the Grenoble C.H.U. are a permanent concern and a true team work between the doctors and the pharmacists. The implementation of cards allowed to optimize the radiopharmaceuticals management by avoiding expenses in relation with the non given drugs. (N.C.)

  9. Electromagnetic radiation and behavioural response of ticks: an experimental test.

    Science.gov (United States)

    Vargová, Blažena; Majláth, Igor; Kurimský, Juraj; Cimbala, Roman; Kosterec, Michal; Tryjanowski, Piotr; Jankowiak, Łukasz; Raši, Tomáš; Majláthová, Viktória

    2018-05-01

    Factors associated with the increased usage of electronic devices, wireless technologies and mobile phones nowadays are present in increasing amounts in our environment. All living organisms are constantly affected by electromagnetic radiation which causes serious environmental pollution. The distribution and density of ticks in natural habitats is influenced by a complex of abiotic and biotic factors. Exposure to radio-frequency electromagnetic field (RF-EMF) constitutes a potential cause altering the presence and distribution of ticks in the environment. Our main objective was to determine the affinity of Dermacentor reticulatus ticks towards RF-EMF exposure. Originally designed and constructed radiation-shielded tube (RST) test was used to test the affinity of ticks under controlled laboratory conditions. All test were performed in an electromagnetic compatibility laboratory in an anechoic chamber. Ticks were irradiated using a Double-Ridged Waveguide Horn Antenna to RF-EMF at 900 and 5000 MHz, 0 MHz was used as control. The RF-EMF exposure to 900 MHz induced a higher concentration of ticks on irradiated arm of RST as opposed to the RF-EMF at 5000 MHz, which caused an escape of ticks to the shielded arm. This study represents the first experimental evidence of RF-EMF preference in D. reticulatus. The projection of obtained results to the natural environment could help assess the risk of tick borne diseases and could be a tool of preventive medicine.

  10. Radiation measurements during cavities conditioning on APS RF test stand

    International Nuclear Information System (INIS)

    Grudzien, D.M.; Kustom, R.L.; Moe, H.J.; Song, J.J.

    1993-01-01

    In order to determine the shielding structure around the Advanced Photon Source (APS) synchrotron and storage ring RF stations, the X-ray radiation has been measured in the near field and far field regions of the RF cavities during the normal conditioning process. Two cavity types, a prototype 352-MHz single-cell cavity and a 352-MHz five-cell cavity, are used on the APS and are conditioned in the RF test stand. Vacuum measurements are also taken on a prototype 352-MHz single-cell cavity and a 352-MHz five-cell cavity. The data will be compared with data on the five-cell cavities from CERN

  11. Non-destructive testing and radiation in industry

    International Nuclear Information System (INIS)

    Woodford, C; Ashby, P.

    2001-01-01

    Non-destructive testing (NDT) is a little known discipline which uses non-invasive and passive techniques to investigate the condition of materials and structures. Some of these techniques employ the use of radioisotopes. The penetrating radiations produced by these materials are applied in various ways to obtain the required information. This presentation is an overview of the application of radioisotopes within the scope of NDT. Notwithstanding the well established use of traditional materials, new forms of radioisotopes are being developed which will extend their capabilities

  12. Neurobehavioral Effects of Space Radiation on Psychomotor Vigilance Tests

    Science.gov (United States)

    Hienz, Robert; Davis, Catherine; Weed, Michael; Guida, Peter; Gooden, Virginia; Brady, Joseph; Roma, Peter

    Neurobehavioral Effects of Space Radiation on Psychomotor Vigilance Tests INTRODUCTION Risk assessment of the biological consequences of living in the space radiation environment represents one of the highest priority areas of NASA radiation research. Of critical importance is the need for a risk assessment of damage to the central nervous system (CNS) leading to functional cognitive/behavioral changes during long-term space missions, and the development of effective shielding or biological countermeasures to such risks. The present research focuses on the use of an animal model that employs neurobehavioral tests identical or homologous to those currently in use in human models of risk assessment by U.S. agencies such as the Depart-ment of Defense and Federal Aviation and Federal Railroad Administrations for monitoring performance and estimating accident risks associated with such variables as fatigue and/or alcohol or drug abuse. As a first approximation for establishing human risk assessments due to exposure to space radiation, the present work provides animal performance data obtained with the rPVT (rat Psychomotor Vigilance Test), an animal analog of the human PVT that is currently employed for human risk assessments via quantification of sustained attention (e.g., 'vigilance' or 'readiness to perform' tasks). Ground-based studies indicate that radiation can induce neurobehavioral changes in rodents, including impaired performance on motor tasks and deficits in spatial learning and memory. The present study is testing the hypothesis that radiation exposure impairs motor function, performance accuracy, vigilance, motivation, and memory in adult male rats. METHODS The psychomotor vigilance test (PVT) was originally developed as a human cognitive neurobe-havioral assay for tracking the temporally dynamic changes in sustained attention, and has also been used to track changes in circadian rhythm. In humans the test requires responding to a small, bright

  13. Chalcogenide Glass Radiation Sensor; Materials Development, Design and Device Testing

    Energy Technology Data Exchange (ETDEWEB)

    Mitkova, Maria; Butt, Darryl; Kozicki, Michael; Barnaby, Hugo

    2013-04-30

    studied the effect of x-rays and γ-rays, on thin film chalcogenide glasses and applied them in conjunction with film incorporating a silver source in a new type of radiation sensor for which we have an US patent application [3]. In this report, we give data about our studies regarding our designed radiation sensor along with the testing and performance at various radiation doses. These studies have been preceded by materials characterization research related to the compositional and structural characteristics of the active materials used in the radiation sensor design. During the work on the project, we collected a large volume of material since every experiment was repeated many times to verify the results. We conducted a comprehensive material research, analysis and discussion with the aim to understand the nature of the occurring effects, design different structures to harness these effects, generated models to aid in the understanding the effects, built different device structures and collected data to quantify device performance. These various aspects of our investigation have been detailed in previous quarterly reports. In this report, we present our main results and emphasize on the results pertaining to the core project goals materials development, sensor design and testing and with an emphasis on classifying the appropriate material and design for the optimal application. The report has three main parts: (i) Presentation of the main data; (ii) Bulleted summary of the most important results; (iii) List of the patent, journal publications, conference proceedings and conferences participation, occurring as a result of working on the project.

  14. AHP 24: A Multi-ethnic Village in Northeast Tibet - History, Ritual, and Daily Life in Chu cha

    Directory of Open Access Journals (Sweden)

    Stobs stag lha སྟོབས་སྟག་ལྷ།

    2013-09-01

    Full Text Available Multi-ethnic Chu cha Village in Mchod rten thang Township, Dpa' ris Tibetan Autonomous County, Gansu Province, China is described in terms of location; population; clothing; language; religion; history; and personal, family, and community rituals. Photographs provide additional information.

  15. Field test of a post-closure radiation monitor

    International Nuclear Information System (INIS)

    Reed, S.; Christy, C.E.; Heath, R.E.

    1995-01-01

    The DOE is conducting remedial actions at many sites contaminated with radioactive materials. After closure of these sites, long-term subsurface monitoring is typically required by law. This monitoring is generally labor intensive and expensive using conventional sampling and analysis techniques. The U.S. Department of Energy's Morgantown Energy Technology Center (METC) has contracted with Babcock and Wilcox to develop a Long-Term Post-Closure Radiation Monitoring System (LPRMS) to reduce these monitoring costs. A prototype LPRMS probe was built, and B ampersand W and FERMCO field tested this monitoring probe at the Fernald Environmental Management Project in the fall of 1994 with funding from the DOE's Office of Technology Development (EM-50) through METC. The system was used to measure soil and water with known uranium contamination levels, both in drums and in situ at depths up to 3 meters. For comparison purposes, measurements were also performed using a more conventional survey probe with a sodium iodide scintillator directly butt-coupled to detection electronics. This paper presents a description and the results of the field tests. The results were used to characterize the lower detection limits, precision and bias of the system, which allowed the DOE to judge the monitoring system's ability to meet its long-term post-closure radiation monitoring needs. Based on the test results, the monitoring system has been redesigned for fabrication and testing in a potential Phase III of this program. If the DOE feels that this system can meet its needs and chooses to continue into Phase III of this program, this redesigned full scale prototype system will be built and tested for a period of approximately a year. Such a system can be used at a variety of radioactively contaminated sites

  16. Pulsar timing arrays and gravity tests in the radiative regime

    Science.gov (United States)

    Lee, K. J.

    2013-11-01

    In this paper, we focus on testing gravity theories in the radiative regime using pulsar timing array observations. After reviewing current techniques to measure the dispersion and alternative polarization of gravitational waves, we extend the framework to the most general situations, where the combinations of a massive graviton and alternative polarization modes are considered. The atlas of the Hellings-Downs functions is completed by the new calculations for these dispersive alternative polarization modes. We find that each mode and corresponding graviton mass introduce characteristic features in the Hellings-Downs function. Thus, in principal, we can not only detect each polarization mode, measure the corresponding graviton mass, but also discriminate the different scenarios. In this way, we can test gravity theories in the radiative regime in a generalized fashion, and such method is a direct experiment, where one can address the gauge symmetry of the gravity theories in their linearized limits. Although current pulsar timing still lacks enough stable pulsars and sensitivity for such practices, we expect that future telescopes with larger collecting areas could make such experiments feasible.

  17. Development and Validation of Kid Tsu Chu Futbol Games for Character Development

    Directory of Open Access Journals (Sweden)

    Sulistiyono

    2017-08-01

    Full Text Available This research aims to develop and validation games to develop character in the students Football School under 12 years age group. This study was conducted using R and D. This study produced a product in the form of games related to the process of training, but can be used to develop the student’s character. Games that resulted from this research given the name “Tsu Chu Kid Futbol Games For Character Development”. Games have the flexible nature can be placed at the warm-up, core, and cooling at a football training process. The game must have at least two training purposes with the provisions of the first objective should be able to develop the character, and the second objective can develop one component among the components of the physical, technical, or tactics.

  18. Redatuming controlled-source electromagnetic data using Stratton–Chu type integral transformations

    DEFF Research Database (Denmark)

    Zhdanov, Michael; Cai, Hongzhu

    2016-01-01

    We present a new method of analyzing controlled-source electromagnetic (CSEM) data based on redatuming of the observed data from the actual receivers into the virtual receivers. We use the Stratton–Chu type integral transform to calculate the EM field in the virtual receivers. The virtual receivers...... can be placed at any desirable position, including close to the target, which increases the sensitivity of the EM data to the target. The developed method provides an effective model-based interpolation/extrapolation tool for electromagnetic field data. This paper demonstrates that redatuming can...... be used for designing the optimized CSEM survey configuration. The numerical examples, for the Kevin Dome Electromagnetic Project Site, illustrate the practical effectiveness of the developed method....

  19. Radiation consequences of the nuclear tests on the Semipalatinsk test site

    International Nuclear Information System (INIS)

    Logachev, V.A.; Logacheva, L.A.

    2001-01-01

    In the paper the results of retrospective evaluation for radiation situation and radiation doses of population in the zones of the Semipalatinsk test site activity influence are presented. For the measurements the data obtained during analysis, study and summarizing of the archival materials including information on nuclear tests on this site and results of radiation surveys, those were carried out after each test were used. The information testifying most substantial environment contamination taking place after four surface explosions (29.08.1949, 24.09.1951, 12.08.1953, 24.08.1956) is presented as well. After these dose-forming explosions the irradiation doses of the population inhabiting out the regime zone have been exceeded the maximum permissible levels. Results of analysis of archival materials were used for assessment of doses of internal and external irradiation of residents of inhabited points situated on the both the territory of the Republic of Kazakhstan - mainly close to the test site - and the territories of a number of regions of the Russian Federation are locating on the little distance from the tests site

  20. Radiation pressure calibration and test mass reflectivities for LISA Pathfinder

    International Nuclear Information System (INIS)

    Korsakova, Natalia; Kaune, Brigitte

    2017-01-01

    This paper describes a series of experiments which were carried out during the main operations of LISA Pathfinder. These experiments were performed by modulating the power of the measurement and reference beams. In one series of experiments the beams were sequentially switched on and off. In the other series of experiments the powers of the beams were modulated within 0.1% and 1% of the constant power. These experiments use recordings of the total power measured on the photodiodes to infer the properties of the Optical Metrology System (OMS), such as reflectivities of the test masses and change of the photodiode efficiencies with time. In the first case the powers are back propagated from the different photodiodes to the same place on the optical bench to express the unknown quantities in the measurement with the complimentary photodiode measurements. They are combined in the way that the only unknown left is the test mass reflectivities. The second experiment compared two estimates of the force applied to the test masses due to the radiation pressure that appears because of the beam modulations. One estimate of the force is inferred from the measurements of the powers on the photodiodes and propagation of this measurement to the test masses. The other estimation of the force is done by calculating it from the change in the main scientific output of the instrument – differential displacement of the two test masses. (paper)

  1. Radiation pressure calibration and test mass reflectivities for LISA Pathfinder

    Science.gov (United States)

    Korsakova, Natalia; Kaune, Brigitte; LPF Collaboration

    2017-05-01

    This paper describes a series of experiments which were carried out during the main operations of LISA Pathfinder. These experiments were performed by modulating the power of the measurement and reference beams. In one series of experiments the beams were sequentially switched on and off. In the other series of experiments the powers of the beams were modulated within 0.1% and 1% of the constant power. These experiments use recordings of the total power measured on the photodiodes to infer the properties of the Optical Metrology System (OMS), such as reflectivities of the test masses and change of the photodiode efficiencies with time. In the first case the powers are back propagated from the different photodiodes to the same place on the optical bench to express the unknown quantities in the measurement with the complimentary photodiode measurements. They are combined in the way that the only unknown left is the test mass reflectivities. The second experiment compared two estimates of the force applied to the test masses due to the radiation pressure that appears because of the beam modulations. One estimate of the force is inferred from the measurements of the powers on the photodiodes and propagation of this measurement to the test masses. The other estimation of the force is done by calculating it from the change in the main scientific output of the instrument - differential displacement of the two test masses.

  2. Radiation protection training award - an innovative approach of testing radiation protection skills in catastrophe management

    International Nuclear Information System (INIS)

    Geringer, T.

    2003-01-01

    Full text: ARC Seibersdorf research is Austria's largest independent research institution. Apart from research and technical development, ARCS also offers special training an radiation protection. Having undergone intensive radiation protection training, security forces are also entitled to test their knowledge in a special 'radiation protection training award'. The prize is awarded in three different grades. ARCS Bronze award guarantees that the holder is competent in, both theoretical and practical aspects of a radiological accident. The follow-up Silver award requires additional competence in emergency management. Candidates having at least five years of professional experience and presenting a written thesis are considered for the Golden award. The holder is not only experienced in radiological catastrophe management including a competent theoretical background, but is also experienced enough to work out and improve his own emergency planning. ARC Seibersdorf research started with their radiation protection award as early as 1968. More then 10 000 candidates have been awarded since then. Most candidates are members of the Austrian Army or other security forces, although everyone above the age of 18 and undergone a basic course in radiation protection is entitled to participate. Even company internal awards have been given to ensure the quality of training applies to ARC Seibersdorf members as well. The prize is awarded in three different grades. ARCS Bronze award guarantees that the holder is competent in both theoretical and practical aspects of a radiological accident. The followup Silver award requires additional competence in emergency management. Candidates having at least five years of professional experience and presenting a written thesis, are considered for the Golden award. The holder is not only experienced in radiological catastrophe management including a competent theoretical background, but is also experienced enough to work out and improve his

  3. Radiation exposure on residents due to semipalatinsk nuclear tests

    International Nuclear Information System (INIS)

    Takada, J.; Hoshi, M.; Nagatomo, T.

    2000-01-01

    Accumulated external radiation doses for residents near Semipalatinsk nuclear test site of the former USSR are presented as a results of the first study by thermoluminescence technique for bricks sampled at several settlements between 1995 and 1997. The external doses which we evaluated from brick dose were up to ∼100 cGy for resident. The external doses at several points in the center of Semipalatinsk city were ∼60 cGy that was remarkably high comparing with the previously reported value based on the military data. A total of 459 nuclear explosions were conducted by the former Union of Soviet Socialist Republics (USSR) from 1949 to 1989 at the Semipalatinsk nuclear test site (SNTS) Kazakhstan, including 87 atmospheric, 26 on the ground, and 364 underground explosions. Total energy release of about 18 Mt equivalent of trinitrotoluene is eleven hundreds times of Hiroshima atomic bomb. However previous reports concerning the effects of radiation on residents near the SNTS based on data provided by the Defense Department of the former USSR do not have direct experimental data concerning effective equivalent dose. They just measured some doses for particular settlements after some nuclear explosions. These do not indicate integrated dose for the residents due to the whole explosions. The technique of thermoluminescence dosimetry (TLD) which had been successfully applied to the dosimetry on Hiroshima and Nagasaki atomic bombs, enabled us to evaluate accumulated external gamma ray doses at specific places due to whole nuclear explosions in the Semipalatinsk test site. TLD technique is well-established one for not only instantaneous exposure like in A-bombs (Hiroshima and Nagasaki) but also prolonged exposure like in dating. Moreover this technique was applicable for dosimetry study of radioactive fallout as shown in studies of Chernobyl accident. The way of external dose estimation from TLD doses for brick will be discussed in case of radioactive fallout. We will

  4. Test of radiation hardness of pcCVD detectors

    Energy Technology Data Exchange (ETDEWEB)

    Schlemme, Steffen [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Technische Universitaet Darmstadt (Germany); Enders, Joachim [Technische Universitaet Darmstadt (Germany); Figuera, P.; Salamone, S. [LNS-INFN Catania (Italy); Fruehauf, J.; Kis, Mladen; Kratz, A.; Kurz, N.; Loechner, S.; Nociforo, Chiara; Schirru, Fabio; Szczepanczyk, B.; Traeger, M.; Visinka, R. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Musumarra, A. [LNS-INFN Catania (Italy); University of Catania (Italy)

    2016-07-01

    The new in-flight separator Super-FRS is under construction at the Facility for Antiproton and Ion Research (FAIR, Darmstadt). Ion rates up to 3 x 10{sup 11} {sup 238}U/spill demand an adaption of detectors to a high radiation environment. A test experiment to investigate the radiation hardness of polycrystalline diamond detectors (pcCVD) was performed at the LNS-INFN in Catania using a {sup 12}C beam at 62 MeV/u and intensities of up to 1.5 pnA. The setup consisted of pcCVD strip detectors to measure the beam profile, a single crystal diamond detector to calibrate the ionisation chamber working in current mode as a beam intensity monitor and a pcCVD sample to be irradiated. The IC used was designed for FAIR and showed a stable counting rate allowing us to calibrate and perform beam intensity measurements with it. The total measured counts on the sample were 8.25 x 10{sup 11} counts/mm{sup 2} over a period of 60 hours. Digital waveforms of the pcCVD signals were taken with an oscilloscope and analysed. The results showed no change of the pcCVD signal properties during the entire irradiation.

  5. NASDA technician test real-time radiation monitoring device

    Science.gov (United States)

    1997-01-01

    A technician from the National Space Development Agency of Japan (NASDA) tests the real-time radiation monitoring device on SPACEHAB at Kennedy Space Center in preparation for the STS-89 mission, slated to be the first Shuttle launch of 1998. STS-89 will be the eighth of nine scheduled Mir dockings and will include a double module of SPACEHAB, used mainly as a large pressurized cargo container for science, logistical equipment and supplies to be exchanged between the orbiter Endeavour and the Russian Space Station Mir. The nine-day flight of STS-89 also is scheduled to include the transfer of the seventh American to live and work aboard the Russian orbiting outpost. Liftoff of Endeavour and its seven-member crew is targeted for Jan. 15, 1998, at 1:03 a.m. EDT from Launch Pad 39A.

  6. Simulation and test of 3D silicon radiation detectors

    International Nuclear Information System (INIS)

    Fleta, C.; Pennicard, D.; Bates, R.; Parkes, C.; Pellegrini, G.; Lozano, M.; Wright, V.; Boscardin, M.; Dalla Betta, G.-F.; Piemonte, C.; Pozza, A.; Ronchin, S.; Zorzi, N.

    2007-01-01

    The work presented here is the result of the collaborative effort between the University of Glasgow, ITC-IRST (Trento) and IMB-CNM (Barcelona) in the framework of the CERN-RD50 Collaboration to produce 3D silicon radiation detectors and study their performance. This paper reports on two sets of 3D devices. IRST and CNM have fabricated a set of single-type column 3D detectors, which have columnar electrodes of the same doping type and an ohmic contact located at the backplane. Simulations of the device behaviour and electrical test results are presented. In particular, current-voltage, capacitance-voltage and charge collection efficiency measurements are reported. Other types of structures called double-sided 3D detectors are currently being fabricated at CNM. In these detectors the sets of n and p columns are made on opposite sides of the device. Electrical and technological simulations and first processing results are presented

  7. Patient radiation dose during fluoroscopy testes with contrast medium

    International Nuclear Information System (INIS)

    Darsalih, Abir Abdelrady El noor

    2016-09-01

    The purpose of this study was to assess the patient radiation dose received in fluoroscopy examinations during contrast medium. The cumulative air kerma (Ck), kerma area product (KAP) and fluoroscopy time were measured for sixty ( male and female ) patients undergoing five fluoroscopy examinations KAP metre which was installed for the purpose of this study. The mean kerma area product were found to be 2.681, 5.1561, 9.85529. 5.7974 and 13.09 Gy.cm"2 for HSG, A.S and D.S, GI Track and sonogram tests, respectively. The obtained mean cumulative dose was were 6.31, 13.88, 24.61, 22.56 and 32.14 mGy for HSG, A.S, A.S and D.S , GI Track, respectively, the mean fluoroscopy time were. 0.18, 0.51,0.89,1.57 and 1.75 min, for HSG, A.S, A.S, and D.S, G1 Track and sonogram test respectively. Patient dose is mainly dependent on the patient size, procedure, equipment used exposure factor and user experience. As KV and mA were controlled by the AEC and it was found to be well calibrated, possible optimization could be achieved by radiologist by decreasing the exposure time if possible. (Author)

  8. First record of Puerulus mesodontus Chan, Ma & Chu, 2013 (Crustacea, Decapoda, Achelata, Palinuridae) from south of Java, Indonesia.

    Science.gov (United States)

    Wardiatno, Yusli; Hakim, Agus Alim; Mashar, Ali; Butet, Nurlisa Alias; Adrianto, Luky; Farajallah, Achmad

    2016-01-01

    Three specimens of Puerulus mesodontus Chan, Ma & Chu, 2013 (Crustacea, Decapoda, Achelata, Palinuridae) were collected from Palabuhanratu Bay, southern Java, Indonesia. There is no previous record on the presence of the species in Indonesia. This finding represents the first record of this species in Java, Indonesia, and confirms that the species is present in the Indian Ocean. The morphological characters of the species are described. This paper contains a new distribution record of a lobster species from Indonesian waters.

  9. Status and update of the National Ignition Facility radiation effects testing program

    International Nuclear Information System (INIS)

    Davis, J F; Serduke, F J; Wuest, C R.

    1998-01-01

    We are progressing in our efforts to make the National Ignition Facility (NIF) available to the nation as a radiation effects simulator to support the Services needs for nuclear hardness and survivability testing and validation. Details of our program were summarized in a paper presented at the 1998 HEART Conference [1]. This paper describes recent activities and updates plans for NIF radiation effects testing. research. Radiation Effects Testing

  10. Radiation flaw detector for testing non-uniform surface bodies of revolution

    International Nuclear Information System (INIS)

    Valevich, M.I.

    1984-01-01

    Radiation flaw detector for testing bodies of revolution with non-uniform surface, welded joints, etc., based on spatial filtration and differentiation of ionizing radiation flux has been described. The calculation of the most important unit of flaw detector - integrators - is made. Experimental studies of the sensitivity have shown, that the radiation flaw detector can be used for rapid testing of products with the sensitivity comparable with the sensitivity of radiographic testing of steel

  11. Test of atomic theory by photoelectron spectrometry with synchrotron radiation

    International Nuclear Information System (INIS)

    Krause, M.O.

    1984-01-01

    The successful combination of synchrotron radiation with electron spectrometry, accomplished at Daresbury, England and Orsay, France, made it possible to investigate sigma/sub x/ and β/sub x/ continuously over the very soft x-ray or the uv range of photon energies. The detailed and highly differentiated data resulting from this advanced experimentation put theory to a stringent test. In the interplay between theory and experiment, sophisticated Hartree Fock (HF) based models were developed which included both relativistic and many-electron effects. These theoretical models have provided us with a better insight than previously possible into the physics of the photon-atom interaction and the electronic structure and dynamics of atoms. However, critical experiments continue to be important for further improvements of theory. A number of such experiments are discussed in this presentation. The dynamic properties determined in these studies include in addition to sigma/sub x/ and β/sub x/ the spin polarization parameters. As a result the comparison between theory and experiment becomes rigorous, detailed and comprehensive. 46 references, 6 figures

  12. Radiation damage calculations for the APT materials test program

    International Nuclear Information System (INIS)

    Corzine, R.K.; Wechsler, M.S.; Dudziak, D.J.; Ferguson, P.D.; James, M.R.

    1999-01-01

    A materials irradiation was performed at the Los Alamos Neutron Science Center (LANSCE) in the fall of 1996 and spring of 1997 in support of the Accelerator Production of Tritium (APT) program. Testing of the irradiated materials is underway. In the proposed APT design, materials in the target and blanket are to be exposed to protons and neutrons over a wide range of energies. The irradiation and testing program was undertaken to enlarge the very limited direct knowledge presently available of the effects of medium-energy protons (∼1 GeV) on the properties of engineering materials. APT candidate materials were placed in or near the LANSCE accelerator 800-MeV, 1-mA proton beam and received roughly the same proton current density in the center of the beam as would be the case for the APT facility. As a result, the proton fluences achieved in the irradiation were expected to approach the APT prototypic full-power-year values. To predict accurately the performance of materials in APT, radiation damage parameters for the materials experiment must be determined. By modeling the experiment, calculations for atomic displacement, helium and hydrogen cross sections and for proton and neutron fluences were done for representative samples in the 17A, 18A, and 18C areas. The LAHET code system (LCS) was used to model the irradiation program, LAHET 2.82 within LCS transports protons > 1 MeV, and neutrons >20 MeV. A modified version of MCNP for use in LCS, HMCNP 4A, was employed to tally neutrons of energies <20 MeV

  13. Radiation-resistance test on optical fiber for artificial satellite

    International Nuclear Information System (INIS)

    Morita, Yosuke; Seguchi, Tadao; Mori, Tatsuo; Miyaji, Yuji.

    1985-01-01

    Radiation resistance of a prototype optical fiber for use in artificial satellites is investigated under a long-term irradiation of gamma rays at relatively low dose rates. The optical fiber tested is composed of a pure silica core and an F-doped cladding. Various aspects of the relations between induced loss and irradiation time are observed and results obtained are discussed. It is generally accepted that a satellite and its equipment should be resistant to a total dose of about 1 x 10 6 rad. In the present test, accordingly, gamma ray irradiation is performed up to a total dose of 1 x 10 6 rad at a dose rate of 1 x 10 4 rad/h (for 100 h), 3 x 10 3 rad/h (333 h) and 1 x 10 3 rad/h (1000 h), and it is shown that the loss induced in this fiber at these dose rates is 23.6 - 27.2, 16.9 - 21.6 and 12.5 - 13.5 dB/km, respectively. On the other hand, it has been reported that the loss induced at the dose rate of 1 x 10 6 rad/h (1 h) is about 600 dB/km, which is much larger than the above values. From these results, the loss at a dose rate of 100 rad/h, which would be expected in a satellite, is estimated at about 10 dB/km. It is concluded that this prototype fiber has a sufficient capability for satellite use with respect to induced loss. (Nogami, K.)

  14. Radiation protection type testing and licensing of diagnostic X-ray equipment in the GDR

    International Nuclear Information System (INIS)

    Taschner, P.; Poulheim, K.F.; Feldheim, W.

    1987-01-01

    The results of more than 10 years experience in type testing and type licensing of diagnostic X-ray equipment with respect to meeting radiation protection requirements as well as the implications for the conduct of these procedures resulting from the introduction of new radiation protection legislation in 1983 and 1984, are described. At present an updated version of the 'Regulation of 16 December 1977 concerning radiation protection type testing and licensing of sealed radiation sources and equipment emitting ionizing radiation' is being prepared. (author)

  15. Standard Test Method for Measuring Dose for Use in Linear Accelerator Pulsed Radiation Effects Tests

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers a calorimetric measurement of the total dose delivered in a single pulse of electrons from an electron linear accelerator or a flash X-ray machine (FXR, e-beam mode) used as an ionizing source in radiation-effects testing. The test method is designed for use with pulses of electrons in the energy range from 10 to 50 MeV and is only valid for cases in which both the calorimeter and the test specimen to be irradiated are“thin” compared to the range of these electrons in the materials of which they are constructed. 1.2 The procedure described can be used in those cases in which (1) the dose delivered in a single pulse is 5 Gy (matl) (500 rd (matl)) or greater, or (2) multiple pulses of a lower dose can be delivered in a short time compared to the thermal time constant of the calorimeter. Matl refers to the material of the calorimeter. The minimum dose per pulse that can be acceptably monitored depends on the variables of the particular test, including pulse rate, pulse uniformity...

  16. Testing the radiation hardness of lead tungstate scintillating crystals

    CERN Document Server

    Shao, M; Li Chuan; Chen, H; Xu, Z Z; Wang, Z M

    2000-01-01

    Large Hadron Collider operation will produce a high radiation background. PbWO/sub 4/ crystals are selected as scintillators for the CMS electromagnetic calorimeter. To reach the precise requirement for energy measurements, a strict requirement for the radiation hardness is needed. In this paper, we present a method for evaluating the radiation hardness and its measurement. Results for several full size (23 cm length) lead tungstate crystals under Co/sup 60/ gamma - ray irradiation are given, investigating the light yield loss and its longitudinal uniformity. (8 refs).

  17. What one should know about radiation. Comparison of radiation burden from the Chernobyl accident and the atomic weapons test

    Energy Technology Data Exchange (ETDEWEB)

    Burtscher, A

    1986-01-01

    The natural radiation burden, that due to the Chernobyl accident and the atmospheric nuclear weapons tests in Austria are compared. The overall Chernobyl burden is estimated at 50-70% of the annual natural burden and thus less than the burden from atmospheric nuclear weapons tests. (G.Q.).

  18. Topical issues of radiographic testing and radiation protection. Papers

    International Nuclear Information System (INIS)

    1992-01-01

    The seven papers demonstrate current developments in radiation protection. The amendment of the Radiation Protection Ordinance and the new Ordinance on the Transport of Hazardous Goods by Road were discussed in particular. A major results of the discussion meeting was the foundation of the working group on 'Transport of radioactive substances'. In terms of radiographic practive, the authors addressed European standardization, instruments and technology in radioscopy, and computer-aided image processing. (orig./HP) [de

  19. Radiation Testing on State-of-the-Art CMOS: Challenges, Plans, and Preliminary Results

    Science.gov (United States)

    LaBel, Kenneth A.; Cohn, Lewis M.

    2009-01-01

    At GOMAC 2007 and 2008, we discussed a variety of challenges for radiation testing of modern semiconductor devices and technologies [1, 2]. In this presentation, we provide more specific details in this on-going investigation focusing on out-of-the-box lessons observed for providing radiation effects assurances as well as preliminary test results.

  20. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Guimarães, M.C.; Silva, C.R.E.; Silva, T.A. da [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Rosado, P.H.G.; Cunha, P.G. [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work. (author)

  1. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    Science.gov (United States)

    Guimarães, M. C.; Silva, C. R. E.; Rosado, P. H. G.; Cunha, P. G.; Da Silva, T. A.

    2018-03-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work.

  2. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    International Nuclear Information System (INIS)

    Guimarães, M.C.; Silva, C.R.E.; Silva, T.A. da; Rosado, P.H.G.; Cunha, P.G.

    2017-01-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work. (author)

  3. Test equipment used for radiation protection type testing of aerosol filters at the National Board of Nuclear Safety and Radiation Protection (SAAS)

    International Nuclear Information System (INIS)

    Ullmann, W.; Przyborowski, S.

    1977-01-01

    Following a description of the overall design of test equipment developed in the SAAS for radiation protection type testing of aerosol filters, the most important physical and technical details concerning the preparation and measurement of test aerosols as well as the sampling procedure upstream and downstream of the filter to the tested, are comprehensively discussed. Furthermore, experiences gained during several years with different devices for mixing and diluting the aerosols are reported. (author)

  4. Les pneumopathies nosocomiales en réanimation de CHU Hassan II de Fès

    Science.gov (United States)

    Shimi, Abdelkarim; Touzani, Soumaya; Elbakouri, Nabil; Bechri, Brahim; Derkaoui, Ali; Khatouf, Mohammed

    2015-01-01

    L'objectif principal de notre étude était d'identifier les bactéries incriminées dans la pneumopathie nosocomiale (PN) au service de réanimation A1 du CHU Hassan II de Fès, en vue d'en améliorer la prise en charge et de diminuer la morbi-mortalité associée. Il s'agit d'une étude rétrospective et descriptive, menée du 1er janvier 2012 au 31 décembre 2013. Seules les infections pulmonaires survenant au-delà de 48 heures de l'admission du patient au service de réanimation ont été incluses. L'incidence de la PN était de 11,2%. Les Bacilles à Gram négatif (BGN) étaient retrouvés dans 48,5% des cas, le Staphylocoque Aureus dans 21,21% des cas et le Klebsiella Pneumoniae était dans 10,7% des cas. Le taux de mortalité était de 48,33%. L’âge, la gravité de la pathologie sous jacente et le retard de l'instauration d'une antibiothérapie adaptée étaient considérées comme facteurs de mauvais pronostic. L’étude de la résistance aux antibiotiques, montre une multirésistance surtout pour les BGN, dont il faut tenir compte en mettant en place une stratégie de prévention active. PMID:26966481

  5. Early test facilities and analytic methods for radiation shielding: Proceedings

    International Nuclear Information System (INIS)

    Ingersoll, D.T.; Ingersoll, J.K.

    1992-11-01

    This report represents a compilation of eight papers presented at the 1992 American Nuclear Society/European Nuclear Society International Meeting. The meeting is of special significance since it commemorates the fiftieth anniversary of the first controlled nuclear chain reaction. The papers contained in this report were presented in a special session organized by the Radiation Protection and Shielding Division in keeping with the historical theme of the meeting. The paper titles are good indicators of their content and are: (1) The origin of radiation shielding research: The Oak Ridge experience, (2) Shielding research at the hanford site, (3) Aircraft shielding experiments at General Dynamics Fort Worth, 1950-1962, (4) Where have the neutrons gone?, a history of the tower shielding facility, (5) History and evolution of buildup factors, (6) Early shielding research at Bettis atomic power laboratory, (7) UK reactor shielding: then and now, (8) A very personal view of the development of radiation shielding theory

  6. GfW-handbook for irradiation test guidelines for radiation hardness of electronic components

    International Nuclear Information System (INIS)

    Braeunig, D.; Wulf, F.; Gaebler, W.; Boden, A.

    1982-12-01

    The purpose of the report is to propose irradiation test methods so that a standardized application of the methods can lead to a better comparison of test results. The interaction of different radiation species with matter - ionization and displacement - is described. Application of appropriate radiation sources, dosimetry problems, and shielding for simulating space radiation effects by laboratory testing is discussed. The description and characteristics of the irradiation sources are presented. Flowcharts of the planning and running of irradiation tests are given. Guidelines for running the tests are established, test methods and test circuits are proposed. The test system offers the capability of measuring devices also of high complexity up to microprocessors. The test results are collected regularly and are published in GfW-Handbook TN53/08, 'Data Compilation of Irradiation Tested Electronic Components'. (orig./HP) [de

  7. The manufacture of system for testing static random access memory radiation effect

    International Nuclear Information System (INIS)

    Chen Rui; Yang Chen

    2008-01-01

    Space radiation effects will lead to single event upset, event latch up and other phenomena in SRAM devices. This paper introduces the hardware, software composition and related testing technology of SRAM radiation effect testing device. Through to the SRAM chip current detection and power protection, it has solved the SRAM chip damage question in the SRAM experiment. It has accessed to the expected experimental data by using the device in different source of radiation conducted on SRAM Experimental study of radiation effects. It provides important references in the assessment of operational life and reinforcement of the memory carried in the satellites. (authors)

  8. Density meters utilizing ionizing radiation: definitions and test methods

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This standard is applicable to density meters utilizing ionizing radiation, designed for the measurement of the density of liquids, slurries or fluidized solids. The standard applies to transmission-type instruments only. Reference to compliance with this standard shall identify any deviations and the reasons for such deviations. Safety aspects are not included but should fulfill the requirements of all relevant internationally accepted standards

  9. Ernest Orlando Lawrence Awards Ceremony for 2011 Award Winners (Presentations, including remarks by Energy Secretary, Dr. Steven Chu)

    International Nuclear Information System (INIS)

    Chu, Steven

    2012-01-01

    The winners for 2011 of the Department of Energy's Ernest Orlando Lawrence Award were recognized in a ceremony held May 21, 2012. Dr. Steven Chu and others spoke of the importance of the accomplishments and the prestigious history of the award. The recipients of the Ernest Orlando Lawrence Award for 2011 are: Riccardo Betti (University of Rochester); Paul C. Canfield (Ames Laboratory); Mark B. Chadwick (Los Alamos National Laboratory); David E. Chavez (Los Alamos National Laboratory); Amit Goyal (Oak Ridge National Laboratory); Thomas P. Guilderson (Lawrence Livermore National Laboratory); Lois Curfman McInnes (Argonne National Laboratory); Bernard Matthew Poelker (Thomas Jeffereson National Accelerator Facility); and Barry F. Smith (Argonne National Laboratory).

  10. Test of scalar meson structure in φ radiative decays

    International Nuclear Information System (INIS)

    Kumano, S.

    1992-12-01

    We show that φ radiative decays into scalar mesons [f 0 (975), a 0 (980) ≡ S] can provide important clues on the internal structures of these mesons. Radiative decay widths vary widely: B.R. = 10 -4 -10 -6 depending on the substructures (qq-bar, qqq-barq-bar, KK-bar, glueball). Hence, we could discriminate among various models by measuring these widths at future φ factories. The understanding of these meson structures is valuable not only in hadron spectroscopy but also in nuclear physics in connection with the widely-used but little-understood σ meson. We also find that the decay φ→S γ →K 0 K-bar 0 γ is not strong enough to pose a significant background problem for studying CP violation via φ→K 0 K-bar 0 at the φ factories. (author)

  11. Dzhezkazgan and associated sandstone copper deposits of the Chu-Sarysu basin, Central Kazakhstan

    Science.gov (United States)

    Box, Stephen E.; Seltmann, Reimar; Zientek, Michael L.; Syusyura, Boris; Creaser, Robert A.; Dolgopolova, Alla

    2012-01-01

    Sandstone-hosted copper (sandstone Cu) deposits occur within a 200-km reach of the northern Chu-Sarysu basin of central Kazakhstan (Dzhezkazgan and Zhaman-Aibat deposits, and the Zhilandy group of deposits). The deposits consist of Cu sulfide minerals as intergranular cement and grain replacement in 10 ore-bearing members of sandstone and conglomerate within a 600- to 1,000-m thick Pennsylvanian fluvial red-bed sequence. Copper metal content of the deposits ranges from 22 million metric tons (Mt, Dzehzkazgan) to 0.13Mt (Karashoshak in the Zhilandy group), with average grades of 0.85 to 1.7% Cu and significant values for silver (Ag) and rhenium (Re). Broader zones of iron reduction (bleaching) of sandstones and conglomerates of the red-bed sequence extend over 10 km beyond each of the deposits along E-NE-trending anticlines, which began to form in the Pennsylvanian. The bleached zones and organic residues within them are remnants of ormer petroleum fluid accumulations trapped by these anticlines. Deposit sites along these F1anticlines are localized at and adjacent to the intersections of nearly orthogonal N-NW-trending F2synclines. These structural lows served to guide the flow of dense ore brines across the petroleum-bearing anticlines, resulting in ore sulfide precipitation where the two fluids mixed. The ore brine was sourced either from the overlying Early Permian lacustrine evaporitic basin, whose depocenter occurs between the major deposits, or from underlying Upper Devonian marine evaporites. Sulfur isotopes indicate biologic reduction of sulfate but do not resolve whether the sulfate was contributed from the brine or from the petroleum fluids. New Re-Os age dates of Cu sulfides from the Dzhezkazgan deposit indicate that mineralization took place between 299 to 309 Ma near the Pennsylvanian-Permian age boundary. At the Dzhezkazgan and some Zhilandy deposits, F2fold deformation continued after ore deposition. Copper orebodies in Lower Permian

  12. Test beam performance of a tracking TRD [Transition Radiation Detector] prototype

    International Nuclear Information System (INIS)

    Shank, J.T.; Whitaker, J.S.; Polychronakos, V.A.; Radeka, V.; Stephani, D.; Beker, H.; Bock, R.K.; Botlo, M.; Fabjan, C.W.; Pfennig, J.; Price, M.J.; Willis, W.J.; Akesson, T.; Chernyatin, V.; Dolgoshein, B.; Nevsky, P.; Potekhin, M.; Romanjuk, A.; Sosnovtsev, V.; Gavrilenko, I.; Muravjev, S.; Shmeleva, A.

    1990-01-01

    A Tracking Transition Radiation Detector prototype has been constructed and tested. It consists of 240 straw tubes, 4 mm in diameter, imbedded in a polyethylene block acting as the radiator. Its performance as an electron identifier as well as a tracking device for minimum ionizing particles has been determined. 2 refs., 6 figs

  13. Compilation of radiation damage test data part III: materials used around high-energy accelerators

    CERN Document Server

    Beynel, P; Schönbacher, H; CERN. Geneva

    1982-01-01

    For pt.II see CERN report 79-08 (1979). This handbook gives the results of radiation damage tests on various engineering materials and components intended for installation in radiation areas of the CERN high-energy particle accelerators. It complements two previous volumes covering organic cable-insulating materials and thermoplastic and thermosetting resins.

  14. Behaviour parameters of rats in the 'Open field' test under combined effect of radiation and non-radiation factors

    International Nuclear Information System (INIS)

    Kadukova, E.M.; Stashkevich, D.G.; Naumov, A.D.; Kuts, F.I.

    2015-01-01

    It was shown that exposure of electromagnetic radiation and emotional stress modifies the level of integrative reaction of CNS rats which were exposed to ionizing radiation in the 'Open field' test. (authors)

  15. Hydrogen-Helium shock Radiation tests for Saturn Entry Probes

    Science.gov (United States)

    Cruden, Brett A.

    2016-01-01

    This paper describes the measurement of shock layer radiation in Hydrogen/Helium mixtures representative of that encountered by probes entering the Saturn atmosphere. Normal shock waves are measured in Hydrogen-Helium mixtures (89:11% by volume) at freestream pressures between 13-66 Pa (0.1-0.5 Torr) and velocities from 20-30 km/s. Radiance is quantified from the Vacuum Ultraviolet through Near Infrared. An induction time of several centimeters is observed where electron density and radiance remain well below equilibrium. Radiance is observed in front of the shock layer, the characteristics of which match the expected diffusion length of Hydrogen.

  16. Energy Frontier Research Centers: Helping Win the Energy Innovation Race (2011 EFRC Summit Keynote Address, Secretary of Energy Chu)

    International Nuclear Information System (INIS)

    Chu, Steven

    2011-01-01

    Secretary of Energy Steven Chu gave the keynote address at the 2011 EFRC Summit and Forum. In his talk, Secretary Chu highlighted the need to 'unleash America's science and research community' to achieve energy breakthroughs. The 2011 EFRC Summit and Forum brought together the EFRC community and science and policy leaders from universities, national laboratories, industry and government to discuss 'Science for our Nation's Energy Future.' In August 2009, the Office of Science established 46 Energy Frontier Research Centers. The EFRCs are collaborative research efforts intended to accelerate high-risk, high-reward fundamental research, the scientific basis for transformative energy technologies of the future. These Centers involve universities, national laboratories, nonprofit organizations, and for-profit firms, singly or in partnerships, selected by scientific peer review. They are funded at $2 to $5 million per year for a total planned DOE commitment of $777 million over the initial five-year award period, pending Congressional appropriations. These integrated, multi-investigator Centers are conducting fundamental research focusing on one or more of several 'grand challenges' and use-inspired 'basic research needs' recently identified in major strategic planning efforts by the scientific community. The purpose of the EFRCs is to integrate the talents and expertise of leading scientists in a setting designed to accelerate research that transforms the future of energy and the environment.

  17. Standard Practice for Dosimetry of Proton Beams for use in Radiation Effects Testing of Electronics

    International Nuclear Information System (INIS)

    McMahan, Margaret A.; Blackmore, Ewart; Cascio, Ethan W.; Castaneda, Carlos; von Przewoski, Barbara; Eisen, Harvey

    2008-01-01

    Representatives of facilities that routinely deliver protons for radiation effect testing are collaborating to establish a set of standard best practices for proton dosimetry. These best practices will be submitted to the ASTM International for adoption

  18. Standard Practice for Dosimetry of Proton Beams for use in Radiation Effects Testing of Electronics

    Energy Technology Data Exchange (ETDEWEB)

    McMahan, Margaret A.; Blackmore, Ewart; Cascio, Ethan W.; Castaneda, Carlos; von Przewoski, Barbara; Eisen, Harvey

    2008-07-25

    Representatives of facilities that routinely deliver protons for radiation effect testing are collaborating to establish a set of standard best practices for proton dosimetry. These best practices will be submitted to the ASTM International for adoption.

  19. An equivalent ground thermal test method for single-phase fluid loop space radiator

    Directory of Open Access Journals (Sweden)

    Xianwen Ning

    2015-02-01

    Full Text Available Thermal vacuum test is widely used for the ground validation of spacecraft thermal control system. However, the conduction and convection can be simulated in normal ground pressure environment completely. By the employment of pumped fluid loops’ thermal control technology on spacecraft, conduction and convection become the main heat transfer behavior between radiator and inside cabin. As long as the heat transfer behavior between radiator and outer space can be equivalently simulated in normal pressure, the thermal vacuum test can be substituted by the normal ground pressure thermal test. In this paper, an equivalent normal pressure thermal test method for the spacecraft single-phase fluid loop radiator is proposed. The heat radiation between radiator and outer space has been equivalently simulated by combination of a group of refrigerators and thermal electrical cooler (TEC array. By adjusting the heat rejection of each device, the relationship between heat flux and surface temperature of the radiator can be maintained. To verify this method, a validating system has been built up and the experiments have been carried out. The results indicate that the proposed equivalent ground thermal test method can simulate the heat rejection performance of radiator correctly and the temperature error between in-orbit theory value and experiment result of the radiator is less than 0.5 °C, except for the equipment startup period. This provides a potential method for the thermal test of space systems especially for extra-large spacecraft which employs single-phase fluid loop radiator as thermal control approach.

  20. Tests of the validity of a model relating frequency of contaminated items and increasing radiation dose

    International Nuclear Information System (INIS)

    Tallentire, A.; Khan, A.A.

    1975-01-01

    The 60 Co radiation response of Bacillus pumilus E601 spores has been characterized when present in a laboratory test system. The suitability of test vessels to act as both containers for irradiation and culture vessels in sterility testing has been checked. Tests have been done with these spores to verify assumptions basic to the general model described in a previous paper. First measurements indicate that the model holds with this laboratory test system. (author)

  1. The Xenon Test Chamber Q-SUN® for testing realistic tolerances of fungi exposed to simulated full spectrum solar radiation.

    Science.gov (United States)

    Dias, Luciana P; Araújo, Claudinéia A S; Pupin, Breno; Ferreira, Paulo C; Braga, Gilberto Ú L; Rangel, Drauzio E N

    2018-06-01

    The low survival of insect-pathogenic fungi when used for insect control in agriculture is mainly due to the deleterious effects of ultraviolet radiation and heat from solar irradiation. In this study, conidia of 15 species of entomopathogenic fungi were exposed to simulated full-spectrum solar radiation emitted by a Xenon Test Chamber Q-SUN XE-3-HC 340S (Q-LAB ® Corporation, Westlake, OH, USA), which very closely simulates full-spectrum solar radiation. A dendrogram obtained from cluster analyses, based on lethal time 50 % and 90 % calculated by Probit analyses, separated the fungi into three clusters: cluster 3 contains species with highest tolerance to simulated full-spectrum solar radiation, included Metarhizium acridum, Cladosporium herbarum, and Trichothecium roseum with LT 50  > 200 min irradiation. Cluster 2 contains eight species with moderate UV tolerance: Aschersonia aleyrodis, Isaria fumosorosea, Mariannaea pruinosa, Metarhizium anisopliae, Metarhizium brunneum, Metarhizium robertsii, Simplicillium lanosoniveum, and Torrubiella homopterorum with LT 50 between 120 and 150 min irradiation. The four species in cluster 1 had the lowest UV tolerance: Lecanicillium aphanocladii, Beauveria bassiana, Tolypocladium cylindrosporum, and Tolypocladium inflatum with LT 50  solar radiation before. We conclude that the equipment provided an excellent tool for testing realistic tolerances of fungi to full-spectrum solar radiation of microbial agents for insect biological control in agriculture. Copyright © 2018 British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  2. Radiation preservation and test marketing of fruits and vegetables

    Science.gov (United States)

    Zhicheng, Xu; Dong, Cai; Fuying, He; Deyao, Zhao

    1993-07-01

    To develop the technology for radiation preservation of fruits and vegetables, many varieties of fruits and vegetables had been researched. Results showed that the low dose irradiation is useful to preservation of fruits and vegetables. On the besis of research, 1900 tons garlic, 950 tons onion, 500 tons potatoes, 710 tons apples and 1000 kg litchi had been irradiated in commercial scale. The quality control standards of irradiated garlic, onion and potato had been established and used for commercial scale irradiation. In order to collect consumers in store response to irradiated foods, a special counter was set up for selling irradiated apples in Nan Jing Road (W), Shanghai. 634 sheets of consumer in-store respense investigation forms have been returned and analysed. These results showed that when consumer understands the benefit of irradiation preservation such as higher quality, greater safety, longer shelf-live, wide product availability, or good prices for value, consumer would willingly buy irradiated food.

  3. Test plan for Digface Chemical and Radiation Assay System

    International Nuclear Information System (INIS)

    Akers, D.W.

    1993-07-01

    The Digface Chemical and Radiation Assay System (CRAS) Project will develop a sensor using Prompt Gamma Neutron Activation Analysis (PGNAA) that can detect the present of hazardous chemicals and radioactive materials. The CRAS is being designed for in situ assay of closed drums and contaminated soils for gamma-ray emitting radionuclides and hazardous elements. The CRAS is based upon the use of 252 Cf PGNAA with a germanium gamma-ray spectrometer as the analyzer. Tasks being performed include determining detection limits for a number of hazardous chemicals and assessing matrix and transmission effects through soil. Initial analyses suggest that the technique is applicable to a number of hazardous materials such as trichloroethane and carbon tetrachloride

  4. Radiation preservation and test marketing of fruits and vegetables

    International Nuclear Information System (INIS)

    Xu Zhicheng; Cai Dong; He Fuying; Zhao Deyao

    1993-01-01

    To develop the technology for radiation preservation of fruits and vegetables, many varieties of fruits and vegetables had been researched. Results showed that low dose irradiation is useful to preserve fruits and vegetables. On the basis of research, 1900 tons of garlic, 950 tons onion, 500 tons potatoes, 710 tons apples and 1000 kg litchi had been irradiated on a commercial scale. The quality control standards of irradiated garlic, onion and potato had been established and used for commercial scale irradiation. In order to collect consumers in-store response to irradiated foods, a special counter was set up for selling irradiated apples in Nan Jing Road (W), Shanghai. 634 sheets of consumer in-store response investigation forms have been returned and analysed. These results showed that when consumer understands the benefit of irradiation preservation such as higher quality, greater safety, longer shelf-life, wide product availability, or good prices for value, consumer would willingly buy irradiated food. (author)

  5. Radiation

    International Nuclear Information System (INIS)

    2013-01-01

    The chapter one presents the composition of matter and atomic theory; matter structure; transitions; origin of radiation; radioactivity; nuclear radiation; interactions in decay processes; radiation produced by the interaction of radiation with matter

  6. Team Update on North American Proton Facilities for Radiation Testing

    Science.gov (United States)

    Label, Kenneth A.; Turflinger, Thomas; Haas, Thurman; George, Jeffrey; Moss, Steven; Davis, Scott; Kostic, Andrew; Wie, Brian; Reed, Robert; Guertin, Steven; hide

    2016-01-01

    In the wake of the closure of the Indiana University Cyclotron Facility (IUCF), this presentation provides an overview of the options for North American proton facilities. This includes those in use by the aerospace community as well as new additions from the cancer therapy regime. In addition, proton single event testing background is provided for understanding the criteria needed for these facilities for electronics testing.

  7. Irradiation tests of critical components for remote handling in gamma radiation environment

    International Nuclear Information System (INIS)

    Obara, Henjiro; Kakudate, Satoshi; Oka, Kiyoshi

    1994-08-01

    Since the fusion power core of a D-T fusion reactor will be highly activated once it starts operation, personnel access will be prohibited so that assembly and maintenance of the components in the reactor core will have to be totally conducted by remote handling technology. Fusion experimental reactors such as ITER require unprecedented remote handling equipments which are tolerable under gamma radiation of more than 10 6 R/h. For this purpose, the Japan Atomic Energy Research Institute (JAERI) has been developing radiation hard components for remote handling purpose and a number of key components have been tested over 10 9 rad at a radiation dose rate of around 10 6 R/h, using Gamma Ray Radiation Test Facility in JAERI-Takasaki Establishment. This report summarizes the irradiation test results and the latest status of AC servo motor, potentiometer, optical elements, lubricant, sensors and cables, which are key elements of the remote handling system. (author)

  8. Design and development of semi-automatic radiation test and calibration facility

    International Nuclear Information System (INIS)

    Yadav, Ashok Kumar; Chouhan, V.K.; Narayan, Pradeep

    2008-01-01

    Semi-automatic gamma radiation test and calibration facility have been designed, developed and commissioned at Defence Laboratory Jodhpur (DLJ). The facility comprises of medium and high dose rate range setup using 30 Ci Cobalt-60 source, in a portable remotely operated Techops camera and a 15000 Ci 60 Co source in a Tele-therapy machine. The radiation instruments can be positioned at any desired position using a computer controlled positioner having three translational and one rotational motion. User friendly software helps in positioning the Device Under Test (DUT) at any desired dose rate or distance and acquire the data automatically. The servo and stepper motor controlled positioner helps in achieving the required precision and accuracy for the radiation calibration of the instruments. This paper describes the semi-automatic radiation test and calibration facility commissioned at DLJ. (author)

  9. Development and testing of a thermoluminescent dosemeter for mixed neutron-photon-beta radiation fields

    International Nuclear Information System (INIS)

    Zummo, J.J.; Liu, J.C.

    1998-08-01

    A new four-element thermoluminescent (TL) dosemeter and dose evaluation algorithm have been developed and tested to better characterize personnel exposure in mixed neutron-photon-beta radiation fields. The prototype dosemeter is based on a commercially available TL card (with three LiF-7 chips and one LiF-6 chip) and modified filtration elements. The new algorithm takes advantage of the high temperature peak characteristics of the LiF-6 element to better quantify the neutron dose component. The dosemeter was tested in various radiation fields, consisting of mixtures of two radiation types typically used for dosemeter performance testing, as well as mixtures of three radiation types to simulate possible exposure conditions. The new dosemeter gave superior performance, based on the tolerance levels, when using the new algorithm as compared to a conventional algorithm that did not use the high temperature peak methodology. The limitations and further improvements are discussed

  10. Technical critique on radiation test facilities for the CTR surface and materials program

    International Nuclear Information System (INIS)

    Persiani, P.J.

    1975-02-01

    Major radiation test facilities will be necessary in the near-term (5 years) and long-term (greater than 10 years) future for the timely development and understanding of fusion confinement systems and of prototype fusion power reactors. The study includes the technical justifications and requirements for CTR Neutron and Plasma Radiation Test Facilities. The initial technical critique covers the feasibility and design problems: in upgrading the performance of the accelerator-rotating (solid TiT) target systems, and in transforming the accelerator-supersonic jet target concept into a radiation testing facility. A scoping assessment on the potential of a pulsed high-beta plasma device (dense plasma focus) is introduced to explore plasma concepts as near-term neutron and plasma radiation sources for the CTR Surface and Materials Program. (U.S.)

  11. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas

    International Nuclear Information System (INIS)

    1990-01-01

    This report describes the Offsite Radiation Safety Program conducted during 1990 by the Environmental Protection Agency's (EPA's) Environmental Monitoring Systems Laboratory -- Las Vegas. This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ion chambers (PICs); and by biological monitoring of animals, food crops, and humans. Personnel with mobile monitoring equipment are placed in areas downwind from the test site prior to each nuclear weapons test to implement protective actions, provide immediate radiation monitoring, and obtain environmental samples rapidly after any occurrence of radioactivity release

  12. IPRT polarized radiative transfer model intercomparison project - Three-dimensional test cases (phase B)

    Science.gov (United States)

    Emde, Claudia; Barlakas, Vasileios; Cornet, Céline; Evans, Frank; Wang, Zhen; Labonotte, Laurent C.; Macke, Andreas; Mayer, Bernhard; Wendisch, Manfred

    2018-04-01

    Initially unpolarized solar radiation becomes polarized by scattering in the Earth's atmosphere. In particular molecular scattering (Rayleigh scattering) polarizes electromagnetic radiation, but also scattering of radiation at aerosols, cloud droplets (Mie scattering) and ice crystals polarizes. Each atmospheric constituent produces a characteristic polarization signal, thus spectro-polarimetric measurements are frequently employed for remote sensing of aerosol and cloud properties. Retrieval algorithms require efficient radiative transfer models. Usually, these apply the plane-parallel approximation (PPA), assuming that the atmosphere consists of horizontally homogeneous layers. This allows to solve the vector radiative transfer equation (VRTE) efficiently. For remote sensing applications, the radiance is considered constant over the instantaneous field-of-view of the instrument and each sensor element is treated independently in plane-parallel approximation, neglecting horizontal radiation transport between adjacent pixels (Independent Pixel Approximation, IPA). In order to estimate the errors due to the IPA approximation, three-dimensional (3D) vector radiative transfer models are required. So far, only a few such models exist. Therefore, the International Polarized Radiative Transfer (IPRT) working group of the International Radiation Commission (IRC) has initiated a model intercomparison project in order to provide benchmark results for polarized radiative transfer. The group has already performed an intercomparison for one-dimensional (1D) multi-layer test cases [phase A, 1]. This paper presents the continuation of the intercomparison project (phase B) for 2D and 3D test cases: a step cloud, a cubic cloud, and a more realistic scenario including a 3D cloud field generated by a Large Eddy Simulation (LES) model and typical background aerosols. The commonly established benchmark results for 3D polarized radiative transfer are available at the IPRT website (http

  13. Identification of Radiation Effects on Carcinogenic Food Estimated by Ames Test

    International Nuclear Information System (INIS)

    Afifi, M.; Eid, I.; El - Nagdy, M.; Zaher, R.; Abd El-Karem, H.; Abd EL Karim, A.

    2016-01-01

    A major concern in studies related to carcinogenesis is the exposure to the exogenous carcinogens that may occur in food in both natural and polluted human environments. The purpose of the present study is to examine some of food products by Ames test to find out if food products carcinogenic then expose food to gamma radiation to find out the effect of radiation on it as a treatment. In this study, the food samples were examined by Ames test (Salmonella typhimurium mutagenicity test) to find out that a food product could be carcinogenic or highly mutated. Testing of chemicals for mutagenicity is based on the knowledge that a substance which is mutagenic in the bacterium is more likely than not to be a carcinogen in laboratory animals, and thus , by extension, present a risk of cancer to humans. After that food products that showed mutagenicity exposed to gamma radiation at different doses to examine the effect of gamma radiation on food products. This study represent γ radiation effect on carcinogenic food by using Ames test in the following steps: Detect food by Ames test using Salmonella typhimurium strains in which the colony count /plate for each food sample will show if food is slightly mutated or highly mutated or carcinogenic. If food is highly mutated or carcinogenic with high number of colonies /plate, then the carcinogenic food or highly mutated food exposed to different doses of radiation The applied doses in this study were 0, 2.5, 5, and 10 (KGy). Detect the radiation effect on food samples by Ames test after irradiation. The study shows that mutated and carcinogenic food products estimated by Ames test could be treated by irradiation

  14. Synthesis of functional materials by radiation and qualification testing of organic materials in nuclear power plant

    International Nuclear Information System (INIS)

    Nho, Young Chang; Kim, Ki Yup; Kang, Phil Hyun and others; Jun, Hong Jae; Suh, Dong Hak; Lee, Young Moo; Min, Byung Kak; Bae, You Han

    2003-05-01

    The radiation crosslinking and grafting can be easily adjusted and is easily reproducible by controlling the radiation dose. These studies aim to develop new biomaterials such as covering for burns and wound, and controlled release of drug. A radiation technology was used to develop PTC materials useful in devices that limit electric fault currents. Radiation-curing of fiber-matrix composites is a promising application. There are a number of advantages to radiation curing of composites, compared with conventional thermal processing. Radiation curing at ambient temperature allows tighter control of part dimensions, and elimination of internal stresses which otherwise occur on cooling and which reduce material strength. These studies involved radiation curing of epoxy resins with various fibers and filler for structural application for aerospace and sport goods. The chain scission is the basis of other radiation treatments aimed at enhancing processing characteristics of polymers. These studies aim to make PTFE powder from PTFE scrap using the radiation degradation which allows incorporation of the material into coatings, inks etc. Low density polyethylene, crosslinked polyethylene, ethylene propylene rubber, and acrylonitrile butadiene rubber as cable insulating, seathing and sealing materials were irradiated for the accelerated ageing tests. Degradation was investigated by measuring dielectric analysis, thermogravimetric analysis, and dynamic mechanical analysis. Dielectric tanδ, storage modulus and loss modulus were increased with irradiation doses. However, decomposition temperature decreased with irradiation doses

  15. Hazards of radiation from continuous nuclear bomb tests

    Energy Technology Data Exchange (ETDEWEB)

    Leipunskii, O I

    1958-01-01

    The hazards from radioactive fallout due to continuous nuclear bomb tests equivalent in intensity to 11 megatons of TNT are studied. Concentrations of /sup 90/Sr in the bones, the rate of leukemia, and the number of the victims of genetic damage are evaluated. The calculations show that towards the end of the century the concentration of /sup 90/Sr in the spine in large groups of the population could exceed the officially permissible dose and each year of continuous tests would result in the birth of 44,000 persons burdened by hereditary sickness, and 29,000 cases of leukemia.

  16. Testing prototypes of novel radiator for LHCb-RICH

    CERN Document Server

    Saini, Divya

    2017-01-01

    The LHCb experiment at CERN aims to look for signals for physics beyond the standard model in particle physics. The data from Ring Imaging Cherenkov detector (RICH) in LHCb are used to identify the hadronic particles that are produced in proton-proton collisions in different momentum ranges. The particle identification performance of the current detector in the 1-10 GeV/c range needs a significant improvement. For this an R&D project to use a new type of radiator using photonic crystals is underway. In a laboratory at CERN, prototypes of crystals will be exposed to charged particles from a source and the Cherenkov photons created will be detected using multianode photomultiplier tubes (MaPMTs). The data collected will be compared with expectations from optical simulations. These simulations use the solutions of Maxwell’s equations based on the quantum mechanical properties of the crystals. The MaPMTs and the optical components outside the crystals are simulated using GEANT4 and analysis involve using t...

  17. Test plan for validation of the radiative transfer equation.

    Energy Technology Data Exchange (ETDEWEB)

    Ricks, Allen Joseph; Grasser, Thomas W.; Kearney, Sean Patrick; Jernigan, Dann A.; Blanchat, Thomas K.

    2010-09-01

    As the capabilities of numerical simulations increase, decision makers are increasingly relying upon simulations rather than experiments to assess risks across a wide variety of accident scenarios including fires. There are still, however, many aspects of fires that are either not well understood or are difficult to treat from first principles due to the computational expense. For a simulation to be truly predictive and to provide decision makers with information which can be reliably used for risk assessment the remaining physical processes must be studied and suitable models developed for the effects of the physics. A set of experiments are outlined in this report which will provide soot volume fraction/temperature data and heat flux (intensity) data for the validation of models for the radiative transfer equation. In addition, a complete set of boundary condition measurements will be taken to allow full fire predictions for validation of the entire fire model. The experiments will be performed with a lightly-sooting liquid hydrocarbon fuel fire in the fully turbulent scale range (2 m diameter).

  18. Testing of environmental radiation monitors using the Risø low-level radiation measurement stations

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.

    2000-01-01

    June, 1999. The chief aims of such experiments are to allow the participants to check their home calibrations of their detectors and to compare the responses of the individual environmental radiation measurement systems used in the different EU member states and making a link between the different...... a simulation of a radioactive plume passing over the monitors during a certain time was made using a specially designed source set up in the field that was able to vary the air kerma rate from low activity Cs-137 sources additional to the natural air kerma rate. It is demonstrated that a typical environmental...

  19. Mortality in Zarinsk area of Altai Krai as a territory exposed to radiation as a result of nuclear tests at the Semipalatinsk test site

    OpenAIRE

    Kolyado I.; Plugin S.

    2017-01-01

    In Altai krai, there exists a regional segment of the National Radiation Epidemiological Register. The most numerous contingent are victims of nuclear tests at the Semipalatinsk testing site. The new method of calculation of cumulative total effective whole-body radiation dose in patients exposed to radiation as a result of nuclear testing at the Semipalatinsk test site allowed expanding this contingent, to a large extent - due to the inhabitants of Zarinsk area of Altai Krai. The given artic...

  20. SP-100 GES/NAT radiation shielding systems design and development testing

    International Nuclear Information System (INIS)

    Disney, R.K.; Kulikowski, H.D.; McGinnis, C.A.; Reese, J.C.; Thomas, K.; Wiltshire, F.

    1991-01-01

    Advanced Energy Systems (AES) of Westinghouse Electric Corporation is under subcontract to the General Electric Company to supply nuclear radiation shielding components for the SP-100 Ground Engineering System (GES) Nuclear Assembly Test to be conducted at Westinghouse Hanford Company at Richland, Washington. The radiation shielding components are integral to the Nuclear Assembly Test (NAT) assembly and include prototypic and non-prototypic radiation shielding components which provide prototypic test conditions for the SP-100 reactor subsystem and reactor control subsystem components during the GES/NAT operations. W-AES is designing three radiation shield components for the NAT assembly; a prototypic Generic Flight System (GFS) shield, the Lower Internal Facility Shield (LIFS), and the Upper Internal Facility Shield (UIFS). This paper describes the design approach and development testing to support the design, fabrication, and assembly of these three shield components for use within the vacuum vessel of the GES/NAT. The GES/NAT shields must be designed to operate in a high vacuum which simulates space operations. The GFS shield and LIFS must provide prototypic radiation/thermal environments and mechanical interfaces for reactor system components. The NAT shields, in combination with the test facility shielding, must provide adequate radiation attenuation for overall test operations. Special design considerations account for the ground test facility effects on the prototypic GFS shield. Validation of the GFS shield design and performance will be based on detailed Monte Carlo analyses and developmental testing of design features. Full scale prototype testing of the shield subsystems is not planned

  1. Motion of a spinning test particle in Vaidya's radiating metric

    International Nuclear Information System (INIS)

    Carmeli, M.; Charach, C.; Kaye, M.

    1977-01-01

    The motion of a spinning test particle in Vaidya's gravitational field is considered in the framework of Papapetrou's equations of motion. Use is made of the supplementary condition S/sup μ//sup u/ = 0, where u is the retarded Schwarzschild time coordinate. We derive the equations for the dynamical variables, and consider the conservation laws, that follow from the equations of motion. Particular cases of motion are also discussed and additional first integrals corresponding to these cases are found. Some of the new extra integrals are related to the Casimir operators of the Poincare group. It is found that under special conditions on the spin tensor components the particle follows a geodesic. Motion of the spinning test particle in the Schwarzschild field is considered as one of the particular cases

  2. The use of bacteriological preparates to test processes in radiation sterilization

    International Nuclear Information System (INIS)

    Gazso, L.; Igali, S.; Kovacs, A.

    1976-01-01

    Environmental factors influencing the irradiation sensitivity of micro-organisms, bacterium stocks being suitable for biological checking up and spore test organism used nowadays are reviewed. According to the tests made on Bacillus pumilus E601 and Bacillus sphaericus Csub(I)A stockes with Noratom, PX-γ-30 and 60 Co radiation sources the irradiation sensitivity of the same products irradiated with the same dose can differ in the function of the radiation source and the dose rate. It seems necessary to produce the test preparates in the same way in a central laboratory and to calibrate them to single radiation sources. It is advisable to check up the factual microbicidal effect of the nominal dosage by a biological dosimeter. The method reviewed potentiates a much higher confidence than that of conventional sterility tests and its additional advantage is the cheapness. (K.A.)

  3. Heat resistant/radiation resistant cable and incore structure test device for FBR type reactor

    International Nuclear Information System (INIS)

    Tanimoto, Hajime; Shiono, Takeo; Sato, Yoshimi; Ito, Kazumi; Sudo, Shigeaki; Saito, Shin-ichi; Mitsui, Hisayasu.

    1995-01-01

    A heat resistant/radiation resistant coaxial cable of the present invention comprises an insulation layer, an outer conductor and a protection cover in this order on an inner conductor, in which the insulation layer comprises thermoplastic polyimide. In the same manner, a heat resistant/radiation resistant power cable has an insulation layer comprising thermoplastic polyimide on a conductor, and is provided with a protection cover comprising braid of alamide fibers at the outer circumference of the insulation layer. An incore structure test device for an FBR type reactor comprises the heat resistant/radiation resistant coaxial cable and/or the power cable. The thermoplastic polyimide can be extrusion molded, and has excellent radiation resistant by the extrusion, as well as has high dielectric withstand voltage, good flexibility and electric characteristics at high temperature. The incore structure test device for the FBR type reactor of the present invention comprising such a cable has excellent reliability and durability. (T.M.)

  4. Pulsed mixed n, γ radiation fields for electronic testing

    International Nuclear Information System (INIS)

    Nurdin, G.; Becret, C.; Jaureguy, J.C.; Vie, M.; Baboulet, J.P.; Lapeyre, P.; Ramisse, D.

    1994-01-01

    For combined n, γ TREE testing we have modified the CALIBAN Fast Burst Reactor Field with CdO/Epoxy converters to cover the range [10 11 -10 12 ] n.cm -2 (1 MeV Si), [10 7 - 10 8 ] cGy(Si).s -1 . Activation and fission σ φvector, 1 MeV(Si) fluences, neutron spectra, total exposures and dose rates were predicted with good agreement by n, γ photon transport codes. (author). 12 refs., 2 figs., 1 tab

  5. [Regulatory radiation risks' for the population and natural objects within the Semipalatinsk Test Site].

    Science.gov (United States)

    Spiridonov, S I; Teten'kin, V L; Mukusheva, M K; Solomatin, V M

    2008-01-01

    Advisability of using risks as indicators for estimating radiation impacts on environmental objects and humans has been jusified. Results are presented from identification of dose burdens distribution to various cohorts of the population living within the Semipalatinsk Test Site (STS) and consuming contaminated farm products. Parameters of dose burden distributions are estimated for areas of livestock grazing and the most contaminated sectors within these areas. Dose distributions to meadow plants for the above areas have been found. Regulatory radiation risks for the STS population and meadow ecosystem components have been calculated. Based on the parameters estimated, levels of radiation exposure of the population and herbaceous plants have been compared.

  6. Results of radiation tests at cryogenic temperature on some selected organic materials for the LHC

    International Nuclear Information System (INIS)

    Tavlet, M.; Schoenbacher, H.

    1999-01-01

    In the near future, particle accelerators and detectors as well as fusion reactors will operate at cryogenic temperatures. At temperatures as low as 2 K, the organic materials used for the insulation of the superconducting magnets and cables will be exposed to high radiation levels. In this work, a representative selection of organic materials comprising insulating films, cable insulations and epoxy-type-impregnated resins were exposed to neutron and gamma radiation of nuclear reactors, both at ambient and cryogenic temperatures, and were subsequently mechanically tested. The results show that the radiation degradation is never worse in a cryogenic fluid than it is in usual ambient conditions. (author)

  7. Monitoring system for testing the radiation hardness of a KINTEX-7 FPGA

    Energy Technology Data Exchange (ETDEWEB)

    Cojocariu, L. N., E-mail: lucian.cojocariu@cern.ch [Horia Hulubei National Institute for R& D in Physics and Nuclear Engineering (Reactorului 30, MG, Romania) (Romania); Stefan cel Mare University of Suceava (Universitatii 13, Suceava, Romania) (Romania); Placinta, V. M., E-mail: vlad-mihai.placinta@cern.ch [Horia Hulubei National Institute for R& D in Physics and Nuclear Engineering (Reactorului 30, MG, Romania) (Romania); University POLITEHNICA of Bucharest (Splaiul Independentei 313, Bucharest, Romania) (Romania); Dumitru, L., E-mail: dlaur@nipne.ro [Horia Hulubei National Institute for R& D in Physics and Nuclear Engineering (Reactorului 30, MG, Romania) (Romania)

    2016-03-25

    A much more efficient Ring Imaging Cherenkov sub-detector system will be rebuilt in the second long shutdown of Large Hadron Collider for the LHCb experiment. Radiation-hard electronic components together with Commercial Off-The-Shelf ones will be used in the new Cherenkov photon detection system architecture. An irradiation program was foreseen to determine the radiation tolerance for the new electronic devices, including a Field Programmable Gate Array from KINTEX-7 family of XILINX. An automated test bench for online monitoring of the XC7K70T KINTEX-7 device operation in radiation conditions was designed and implemented by the LHCb Romanian group.

  8. Professional exposure to ionizing radiation some hematological cytomorfological and immunological tests

    International Nuclear Information System (INIS)

    Trajkovicj, M.; Veljkovicj, D.; Barjaktarevicj, N.; Kosticj, V.; Brkicj, S.; Pendicj, B.

    1977-01-01

    The paper represents results of some hematological, cytomorphological and immunological tests for persons professionally exposed to ionizing radiations. Number of leucocytes, neutrophil granulocytes and lymphocytes do not show statistically significant differences between the exposed and control groups. An increase of binucleated lymphocytes and chromosome abberations is registered, the second being statistically significant in comparison to the control group. A small depression in cellular immunity is observed for several persons working with ionizing radiation for a longer period

  9. Radiation hardening and irradiation testing of in-cell electronics for MA23/APM

    International Nuclear Information System (INIS)

    Friant, A.

    1988-09-01

    We relate briefly the radiation hardening method used to guarantee a gamma resistance of 10 Mrad for the whole electronic equipment associated with the slave arm of MA23 M servomanipulator which will be set up in cell 404 in Marcoule (APM). We describe the radiation testing of electronic devices and of the various subsystems designed by the D. LETI groups involved in the MA23/APM project

  10. Multiple group radiator and hybrid test heads, possibilities of combining the array technique

    International Nuclear Information System (INIS)

    Wuestenberg, H.

    1993-01-01

    This article is intended to show the important considerations, which led to the development of the multichannel group radiator technique. Trends in development and the advantages and disadvantages of the different possibilities are introduced, against the background of experience now available for these configurative variants of ultrasonic test heads. For this reason, a series of experiences and arguments is reported, from the point of view of the developer of the multi-channel group radiator technique. (orig./HP) [de

  11. Radiation Effects and Component Hardening testing program at the Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Draper, J.V.; Weil, B.S.; Chesser, J.B.

    1993-01-01

    This paper describes Phase II of the Radiation Effects and Component Hardening (REACH) testing program, performed as part of the joint collaborative agreement between the United States Department of Energy (USDOE) and the Power Reactor and Nuclear Fuel Development Corporation (PNC) of Japan, Components and materials were submitted to 10 5 R/hr gamma radiation fields for 10,000 hr, producing accumulated doses of 10 9 R; most performed as expected

  12. Change of notch impact strength depending on radiation dose and test temperature

    Directory of Open Access Journals (Sweden)

    Martin Bednarik

    2017-01-01

    Full Text Available The main purpose of this paper has been determine the effect of radiation crosslinking on the notch impact strength of polyamides filled with fiberglass. These properties were examined in dependence on the dosage of the ionizing beta radiation (non-irradiated samples and those irradiated by dosage 66 and 132 kGy were compared and on the test temperature (23–150 °C.

  13. Decreasing the radiation quality factor of magnetic dipole antennas by a magnetic-coated metal core

    DEFF Research Database (Denmark)

    Kim, Oleksiy S.; Breinbjerg, Olav

    2010-01-01

    To achieve the Chu lower bound for the radiation Q, an electrically small magnetic dipole antenna should not store any magnetic energy internally to the minimum sphere enclosing the antenna. As shown in our previous works, the internal stored magnetic energy can be reduced, although not entirely...... eliminated, by introducing a solid magnetic core inside the antenna. In this paper, using analytical results obtained though the vector spherical wave theory, we show that the internal stored magnetic energy can be further reduced, and the Chu lower bound reached, for a spherical magnetic dipole antenna...

  14. Potential mirror concepts for radiation testing of fusion reactor materials

    International Nuclear Information System (INIS)

    Miley, G.H.

    1977-01-01

    Studies under the University of Illinois PROMETHEUS (Plasma Reactor Optimized for Materials Experimentation for Thermonuclear Energy Usage) project are described that started in 1971 with the realization that a practical fusion-plasma neutron source was feasible with a net-power input (rather than production). The basic objectives were similar to those in later FERF (Fusion Engineering Research Facility) studies: namely, to maximize the neutron flux and usable experimental volume; to include the flexibility to handle a variety of both materials and engineering experiments; to minimize capital and operating costs; and to utilize near- term technology. The PROMETHEUS design provides a neutron flux of approximately 5x10 14 n/cm 2 s by injection of approximately 30 MW of neutral-beams into a 20 cm radius mirror-confined plasma. Charge-exchange bombardment of the first wall is viewed as a key problem in the design and is discussed in some detail. To gain yet higher neutron fluxes for accelerated testing, two alternate designs have been studied: a 'Twin-beam' injection device and a field reversed mirror concept. The latter potentially offers fluxes approaching 10 16 n/cm 2 s but involves more speculative technology. (Auth.)

  15. An experimental test of the linear no-threshold theory of radiation carcinogenesis

    International Nuclear Information System (INIS)

    Cohen, B.L.

    1990-01-01

    There is a substantial body of quantitative information on radiation-induced cancer at high dose, but there are no data at low dose. The usual method for estimating effects of low-level radiation is to assume a linear no-threshold dependence. if this linear no-threshold assumption were not used, essentially all fears about radiation would disappear. Since these fears are costing tens of billions of dollars, it is most important that the linear no-threshold theory be tested at low dose. An opportunity for possibly testing the linear no-threshold concept is now available at low dose due to radon in homes. The purpose of this paper is to attempt to use this data to test the linear no-threshold theory

  16. Application of complex programmable logic devices in memory radiation effects test system

    International Nuclear Information System (INIS)

    Li Yonghong; He Chaohui; Yang Hailiang; He Baoping

    2005-01-01

    The application of the complex programmable logic device (CPLD) in electronics is emphatically discussed. The method of using software MAX + plus II and CPLD are introduced. A new test system for memory radiation effects is established by using CPLD devices-EPM7128C84-15. The old test system's function are realized and, moreover, a number of small scale integrated circuits are reduced and the test system's reliability is improved. (authors)

  17. Low level radiation testing of micro-electronic components. Pt. 1

    International Nuclear Information System (INIS)

    Farren, J.; Stephen, J.H.; Mapper, D.; Sanderson, T.K.; Hardman, M.

    1984-05-01

    A review of the existing literature has been carried out, dealing with the current technology relating to low level radiation testing of microelectronic devices, as used in space satellite systems. After consideration of the space radiation environment, the general effects of cosmic radiation on MOSFET structures and other MOS devices have been assessed. The important aspect of annealing phenomena in relation to gamma-ray induced damage has also been reviewed in detail. The experimental and theoretical aspects of radiation testing have been assessed, with particular reference to the Harwell LORAD low level irradiation test facility. In addition, a review of modern dosimetry methods has been carried out, with specific regard to the problems of accurately measuring low radiation fields (1 to 10 R/hour) over periods of many months. Finally, a detailed account of the proposed experimental programme to be carried out in the LORAD facility is presented, and aspects of the experimental set-up discussed. The particular types of test circuits to be studied are dealt with, and full consideration is given to the various CMOS memory devices of special interest in the ESA space satellite programme. (author)

  18. Radiation monitoring for the HTTR rise-to-power test (1) and (2)'

    Energy Technology Data Exchange (ETDEWEB)

    Nakazawa, Takashi; Yoshino, Toshiaki; Yasu, Katsuji; Ashikagaya, Yoshinobu; Kikuchi, Toshiki [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment

    2001-02-01

    The High Temperature Engineering Test Reactor (HTTR) is the first high temperature gas-cooled research reactor in Japan. This reactor is a helium-gas-cooled and graphite-moderated reactor with a thermal output of 30 MW. The rated operation temperature of the outlet coolant is 850degC. (During high temperature test operation, this reaches 950degC). The first criticality of the HTTR was attained in November 1998. The single loaded, parallel loaded operation with a thermal output of 9 MW (called the HTTR Rise-to-Power Test (1)) was completed between September 16, 1999 and July 8, 2000. The single loaded, parallel loaded continuous operation with a thermal output of 20 MW (called the HTTR Rise-to-Power Test (2)) has also been carried out, but it was shutdown at the halfway stage by a single from the reactor, when the thermal output was 16.5 MW and the reactor outlet coolant temperature was 500degC. This report describes the radiation monitoring carried out during the HTTR Rise-to-Power Tests (1) and (2)'. The data measured by the various radiation monitors is also reported. These data will be used for the estimation of radiation levels (such as the radiation dose equivalent rate, the radioactive concentration in effluents, etc.) for the next HTTR Rise-to-Power Test, and for periodic inspections. (author)

  19. Offsite environmental monitoring report; radiation monitoring around United States nuclear test areas, Calendar Year 1996

    International Nuclear Information System (INIS)

    Davis, M.G.; Flotard, R.D.; Fontana, C.A.; Huff, P.A.; Maunu, H.K.; Mouck, T.L.; Mullen, A.A.; Sells, M.D.

    1997-08-01

    This report describes the Offsite Radiation Safety Program. This laboratory operated an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs); and using pressurized ionization chambers (PICs). No nuclear weapons testing was conducted in 1996 due to the continuing nuclear test moratorium. During this period, R and IE personnel maintained readiness capability to provide direct monitoring support if testing were to be resumed and ascertained compliance with applicable EPA, DOE, state, and federal regulations and guidelines. Comparison of the measurements and sample analysis results with background levels and with appropriate standards and regulations indicated that there was no airborne radioactivity from diffusion or resuspension detected by the various EPA monitoring networks surrounding the NTS. There was no indication of potential migration of radioactivity to the offsite area through groundwater and no radiation exposure above natural background was received by the offsite population. All evaluated data were consistent with previous data history

  20. Online fault diagnostics and testing of area gamma radiation monitor using wireless network

    Science.gov (United States)

    Reddy, Padi Srinivas; Kumar, R. Amudhu Ramesh; Mathews, M. Geo; Amarendra, G.

    2017-07-01

    Periodical surveillance, checking, testing, and calibration of the installed Area Gamma Radiation Monitors (AGRM) in the nuclear plants are mandatory. The functionality of AGRM counting electronics and Geiger-Muller (GM) tube is to be monitored periodically. The present paper describes the development of online electronic calibration and testing of the GM tube from the control room. Two electronic circuits were developed, one for AGRM electronic test and another for AGRM detector test. A dedicated radiation data acquisition system was developed using an open platform communication server and data acquisition software. The Modbus RTU protocol on ZigBee based wireless communication was used for online monitoring and testing. The AGRM electronic test helps to carry out the three-point electronic calibration and verification of accuracy. The AGRM detector test is used to verify the GM threshold voltage and the plateau slope of the GM tube in-situ. The real-time trend graphs generated during these tests clearly identified the state of health of AGRM electronics and GM tube on go/no-go basis. This method reduces the radiation exposures received by the maintenance crew and facilitates quick testing with minimum downtime of the instrument.

  1. Radiation Testing, Characterization and Qualification Challenges for Modern Microelectronics and Photonics Devices and Technologies

    Science.gov (United States)

    LaBel, Kenneth A.; Cohn, Lewis M.

    2008-01-01

    At GOMAC 2007, we discussed a selection of the challenges for radiation testing of modern semiconductor devices focusing on state-of-the-art memory technologies. This included FLASH non-volatile memories (NVMs) and synchronous dynamic random access memories (SDRAMs). In this presentation, we extend this discussion in device packaging and complexity as well as single event upset (SEU) mechanisms using several technology areas as examples including: system-on-a-chip (SOC) devices and photonic or fiber optic systems. The underlying goal is intended to provoke thought for understanding the limitations and interpretation of radiation testing results.

  2. The 88-Inch Cyclotron: A One-Stop Facility for Electronics Radiation and Detector Testing

    Energy Technology Data Exchange (ETDEWEB)

    Kireeff Covo, M.; Albright, R. A.; Ninemire, B. F.; Johnson, M. B.; Hodgkinson, A.; Loew, T.; Benitez, J. Y.; Todd, D. S.; Xie, D. Z.; Perry, T.; Phair, L.; Bernsteiny, L. A.; Bevins, J.; Brown, J. A.; Goldblum, B. L.; Harasty, M.; Harrig, K. P.; Laplace, T. A.; Matthews, E. F.; Bushmaker, A.; Walker, D.; Oklejas, V.; Hopkins, A. R.; Bleuel, D. L.; Chen, J.; Cronin, S. B.

    2017-10-01

    In outer space down to the altitudes routinely flown by larger aircrafts, radiation can pose serious issues for microelectronics circuits. The 88-Inch Cyclotron at Lawrence Berkeley National Laboratory is a sector-focused cyclotron and home of the Berkeley Accelerator Space Effects Facility, where the effects of energetic particles on sensitive microelectronics are studied with the goal of designing electronic systems for the space community. This paper describes the flexibility of the facility and its capabilities for testing the bombardment of electronics by heavy ions, light ions, and neutrons. Experimental capabilities for the generation of neutron beams from deuteron breakups and radiation testing of carbon nanotube field effect transistor will be discussed.

  3. Design, fabrication, and dynamic testing of a V-groove radiator mechanical development unit

    Science.gov (United States)

    Petrick, S. Walter; Bard, Steven

    1988-01-01

    This paper describes the design, fabrication, and dynamic testing of a V-groove radiator development unit. The intended goal was to survive the dynamic environment of the Mars Observer mission. The development unit was designed to achieve a temperature of 80 K with a heat load of about 80 milliwatts. An analysis was performed to predict the thermal performance of the development unit. The radiator with a mass mockup of a Gamma Ray Spectrometer detector, the most massive of the candidate Mars Observer instrument detectors (1.7 Kg), passed vibration and acoustic testing to the Mars Observer requirements in effect at that time.

  4. Verification test for radiation reduction effect and material integrity on PWR primary system by zinc injection

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, H.; Nagata, T.; Yamada, M. [Nuclear Power Engineering Corp. (Japan); Kasahara, K.; Tsuruta, T.; Nishimura, T. [Mitsubishi Heavy Industries, Ltd. (Japan); Ishigure, K. [Saitama Inst. of Tech. (Japan)

    2002-07-01

    Zinc injection is known to be an effective method for the reduction of radiation source in the primary water system of a PWR. There is a need to verify the effect of Zn injection operation on radiation source reduction and materials integrity of PWR primary circuit. In order to confirm the effectiveness of Zn injection, verification test as a national program sponsored by Ministry of Economy, Trade and Industry (METI) was started in 1995 for 7-year program, and will be finished by the end of March in 2002. This program consists of irradiation test and material integrity test. Irradiation test as an In-Pile-Test managed by AEAT Plc(UK) was performed using the LVR-15 reactor of NRI Rez in Check Republic. Furthermore, Out-of-Pile-Test using film adding unit was also performed to obtain supplemental data for In-Pile-Test at Takasago Engineering Laboratory of NUPEC. Material Integrity test was planned to perform constant load test, constant strain test and corrosion test at the same time using large scale Loop and slow strain extension rate testing (SSRT) at Takasago Engineering Laboratory of NUPEC. In this paper, the results of the verification test for Zinc program at present are discussed. (authors)

  5. Standards for radiation protection instrumentation: design of safety standards and testing procedures

    International Nuclear Information System (INIS)

    Meissner, Frank

    2008-01-01

    This paper describes by means of examples the role of safety standards for radiation protection and the testing and qualification procedures. The development and qualification of radiation protection instrumentation is a significant part of the work of TUV NORD SysTec, an independent expert organisation in Germany. The German Nuclear Safety Standards Commission (KTA) establishes regulations in the field of nuclear safety. The examples presented may be of importance for governments and nuclear safety authorities, for nuclear operators and for manufacturers worldwide. They demonstrate the advantage of standards in the design of radiation protection instrumentation for new power plants, in the upgrade of existing instrumentation to nuclear safety standards or in the application of safety standards to newly developed equipment. Furthermore, they show how authorities may proceed when safety standards for radiation protection instrumentation are not yet established or require actualization. (author)

  6. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1991

    Energy Technology Data Exchange (ETDEWEB)

    Chaloud, D.J.; Dicey, B.B.; Mullen, A.A.; Neale, A.C.; Sparks, A.R.; Fontana, C.A.; Carroll, L.D.; Phillips, W.G.; Smith, D.D.; Thome, D.J.

    1992-01-01

    This report describes the Offsite Radiation Safety Program conducted during 1991 by the Environmental Protection Agency`s (EPA`s) Environmental Monitoring Systems Laboratory-Las Vegas. This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ion chambers (PICs); and by biological monitoring of animals, food crops, and humans. Personnel with mobile monitoring equipment are placed in areas downwind from the test site prior to each nuclear weapons test to implement protective actions, provide immediate radiation monitoring, and obtain environmental samples rapidly after any occurrence of radioactivity release. Comparison of the measurements and sample analysis results with background levels and with appropriate standards and regulations indicated that there was no radioactivity detected offsite by the various EPA monitoring networks and no exposure above natural background to the population living in the vicinity of the NTS that could be attributed to current NTS activities. Annual and long-term trends were evaluated in the Noble Gas, Tritium, Milk Surveillance, Biomonitoring, TLD, PIC networks, and the Long-Term Hydrological Monitoring Program.

  7. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1991

    International Nuclear Information System (INIS)

    Chaloud, D.J.; Dicey, B.B.; Mullen, A.A.; Neale, A.C.; Sparks, A.R.; Fontana, C.A.; Carroll, L.D.; Phillips, W.G.; Smith, D.D.; Thome, D.J.

    1992-01-01

    This report describes the Offsite Radiation Safety Program conducted during 1991 by the Environmental Protection Agency's (EPA's) Environmental Monitoring Systems Laboratory-Las Vegas. This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ion chambers (PICs); and by biological monitoring of animals, food crops, and humans. Personnel with mobile monitoring equipment are placed in areas downwind from the test site prior to each nuclear weapons test to implement protective actions, provide immediate radiation monitoring, and obtain environmental samples rapidly after any occurrence of radioactivity release. Comparison of the measurements and sample analysis results with background levels and with appropriate standards and regulations indicated that there was no radioactivity detected offsite by the various EPA monitoring networks and no exposure above natural background to the population living in the vicinity of the NTS that could be attributed to current NTS activities. Annual and long-term trends were evaluated in the Noble Gas, Tritium, Milk Surveillance, Biomonitoring, TLD, PIC networks, and the Long-Term Hydrological Monitoring Program

  8. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1997

    Energy Technology Data Exchange (ETDEWEB)

    Davis, M.G.; Flotard, R.D.; Fontana, C.A.; Hennessey, P.A.; Maunu, H.K.; Mouck, T.L.; Mullen, A.A.; Sells, M.D.

    1999-01-01

    This report describes the Offsite Radiological Environmental Monitoring Program (OREMP) conducted during 1997 by the US Environmental Protection Agency`s (EPAs), Radiation and Indoor Environments National Laboratory, Las Vegas, Nevada. This laboratory operated an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling and analyzing milk, water, and air; by deploying and reading thermoluminescent dosimeters (TLDs); and using pressurized ionization chambers (PICs) to measure ambient gamma exposure rates with a sensitivity capable of detecting low level exposures not detected by other monitoring methods.

  9. Thermal Vacuum Test of Ice as a Phase Change Material Integrated with a Radiator

    Science.gov (United States)

    Lee, Steve A.; Leimkuehler, Thomas O.; Stephan, Ryan; Le, Hung V.

    2010-01-01

    Water may be used as radiation shielding for Solar Particle Events (SPE) to protect crewmembers in the Lunar Electric Rover (LER). Because the water is already present for radiation protection, it could also provide a mass efficient solution to the vehicle's thermal control system. This water can be frozen by heat rejection from a radiator and used as a Phase Change Material (PC1V1) for thermal storage. Use of this water as a PCM can eliminate the need for a pumped fluid loop thermal control system as well as reduce the required size of the radiator. This paper describes the testing and analysis performed for the Rover Engineering Development Unit (REDU), a scaled-down version of a water PCM heat sink for the LER. The REDU was tested in a thermal-vacuum chamber at environmental temperatures similar to those of a horizontal radiator panel on the lunar surface. Testing included complete freeze and melt cycles along with scaled transient heat load profiles simulating a 24-hour day for the rover.

  10. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1993

    Energy Technology Data Exchange (ETDEWEB)

    Chaloud, D.J; Daigler, D.M.; Davis, M.G. [and others

    1996-06-01

    This report describes the Offsite Radiation Safety Program conducted during 1993 by the Environmental Protection Agency`s (EPA`s) Environmental Monitoring Systems Laboratory - Las Vegas (EMSL-LV). This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ionization chambers (PICs); by biological monitoring of foodstuffs including animal tissues and food crops; and by measurement of radioactive material deposited in humans.

  11. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1993

    International Nuclear Information System (INIS)

    Chaloud, D.J; Daigler, D.M.; Davis, M.G.

    1996-06-01

    This report describes the Offsite Radiation Safety Program conducted during 1993 by the Environmental Protection Agency's (EPA's) Environmental Monitoring Systems Laboratory - Las Vegas (EMSL-LV). This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ionization chambers (PICs); by biological monitoring of foodstuffs including animal tissues and food crops; and by measurement of radioactive material deposited in humans

  12. Offsite environmental monitoring report. Radiation monitoring around United States nuclear test areas, calendar year 1997

    International Nuclear Information System (INIS)

    Davis, M.G.; Flotard, R.D.; Fontana, C.A.; Hennessey, P.A.; Maunu, H.K.; Mouck, T.L.; Mullen, A.A.; Sells, M.D.

    1999-01-01

    This report describes the Offsite Radiological Environmental Monitoring Program (OREMP) conducted during 1997 by the US Environmental Protection Agency's (EPAs), Radiation and Indoor Environments National Laboratory, Las Vegas, Nevada. This laboratory operated an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling and analyzing milk, water, and air; by deploying and reading thermoluminescent dosimeters (TLDs); and using pressurized ionization chambers (PICs) to measure ambient gamma exposure rates with a sensitivity capable of detecting low level exposures not detected by other monitoring methods

  13. Radiation Tolerance Qualification Tests of the Final Source Interface Unit for the ALICE Experiment

    CERN Document Server

    Dénes, E; Futó, E; Kerék, A; Kiss, T; Molnár, J; Novák, D; Soós, C; Tölyhi, T; Van de Vyvre, P

    2007-01-01

    The ALICE Detector Data Link (DDL) is a high-speed optical link designed to interface the readout electronics of ALICE sub-detectors to the DAQ computers. The Source Interface Unit (SIU) of the DDL will operate in radiation environment. Previous tests showed that a configuration loss of SRAM-based FPGA devices may happen and the frequency of undetected data errors in the FPGA user memory area is also not acceptable. Therefore, we redesigned the SIU card using another FPGA based on flash technology. In order to detect bit errors in the user memory we added parity check logic to the design. The new SIU has been extensively tested using neutron and proton irradiation to verify its radiation tolerance. In this paper we summarize the design changes, introduce the final design, and the results of the radiation tolerance measurements on the final card.

  14. Irradiation tests of critical components for remote handling system in gamma radiation environment

    International Nuclear Information System (INIS)

    Obara, Kenjiro; Kakudate, Satoshi; Oka, Kiyoshi

    1996-03-01

    This report covers the gamma ray irradiation tests according to the Agreement of ITER R and D Task (T35) in 1994 and describes radiation hardness of the standard components for the ITER remote handling system which are categorized into the robotics (Subtask-1), the viewing system (Subtask-2) and the common components (Subtask-3). The gamma ray irradiation tests have been conducted using No.2 and No.3 cells at the cobalt building of Takasaki Establishment in JAERI. The radiation source is cobalt sixty (Co-60), and the maximum dose rate of No.2 and No.3 cells is about 1x10 6 R/h and 2x10 6 R/h, respectively. The environmental conditions of the irradiation tests are described below and all of components excepting electrical wires have been tested in the No.2 cell. [No.2 cell : Atmosphere and ambient temperature No.3 cell : Nitrogen gas and 250degC] As a whole, many of components have been irradiated up to the rated dose of around 1x10 10 rads and the following main results are obtained. The developed AC servo motor and periscope for radiation use have shown excellent durability with the radiation hardness tolerable for more than 10 9 rads. An electrical connector compatible with remote operation has also shown no degradation of electrical characteristics after the irradiation of 10 10 rads. As for polyimide insulated wires, the mechanical and electrical characteristics are not degradated after the irradiation of 10 9 rads and more radiation hardness can be expected than the anticipation. On the contrary, standard position sensors such as rotary encoder show extremely low radiation hardness and further efforts have to be made for improvements. (J.P.N.)

  15. Radiation monitoring around United States nuclear test areas, calendar year 1989

    Energy Technology Data Exchange (ETDEWEB)

    1990-05-01

    This report describes the Offsite Radiation Safety Program conducted during 1989 by the Environmental Protection Agency's (EPA's) Environmental Monitoring Systems Laboratory-Las Vegas (EMSL-LV). This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels, and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether the testing is in compliance with existing radiation protection standards, and to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ion chambers (PICs); and by biological monitoring of both animals and humans. To implement protective actions, provide immediate radiation monitoring, and obtain environmental samples rapidly after any release of radioactivity, personnel with mobile monitoring equipment are placed in areas downwind from the test site prior to each test. Comparison of the measurements and sample analysis results with background levels and with appropriate standards and regulations indicated that there was no radioactivity detected offsite by the various EPA monitoring networks and no exposure above natural background to the population living in the vicinity of the NTS that could be attributed to NTS activities. Trends were evaluated in the Noble Gas and Tritium, Milk Surveillance, TLD, and PIC networks, and the Long-Term Hydrological Monitoring Program. 35 refs., 68 figs., 32 tabs.

  16. Radiation monitoring around United States nuclear test areas, calendar year 1989

    International Nuclear Information System (INIS)

    1990-05-01

    This report describes the Offsite Radiation Safety Program conducted during 1989 by the Environmental Protection Agency's (EPA's) Environmental Monitoring Systems Laboratory-Las Vegas (EMSL-LV). This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels, and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether the testing is in compliance with existing radiation protection standards, and to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ion chambers (PICs); and by biological monitoring of both animals and humans. To implement protective actions, provide immediate radiation monitoring, and obtain environmental samples rapidly after any release of radioactivity, personnel with mobile monitoring equipment are placed in areas downwind from the test site prior to each test. Comparison of the measurements and sample analysis results with background levels and with appropriate standards and regulations indicated that there was no radioactivity detected offsite by the various EPA monitoring networks and no exposure above natural background to the population living in the vicinity of the NTS that could be attributed to NTS activities. Trends were evaluated in the Noble Gas and Tritium, Milk Surveillance, TLD, and PIC networks, and the Long-Term Hydrological Monitoring Program. 35 refs., 68 figs., 32 tabs

  17. Offsite environmental monitoring report. Radiation monitoring around United States nuclear test areas, calendar year 1982

    International Nuclear Information System (INIS)

    Black, S.C.; Grossman, R.F.; Mullen, A.A.; Potter, G.D.; Smith, D.D.

    1983-07-01

    A principal activity of the Offsite Radiological Safety Program is routine environmental monitoring for radioactive materials in various media and for radiation in areas which may be affected by nuclear tests. It is conducted to document compliance with standards, to identify trends, and to provide information to the public. This report summarizes these activities for CY 1982

  18. In situ radiation measurements at the former Soviet Nuclear Test Site

    International Nuclear Information System (INIS)

    Tipton, W.J.

    1996-06-01

    A team from the Remote Sensing Laboratory conducted a series of in situ radiological measurements at the former Soviet Nuclear Test Site near Semipalatinsk, Kazakhstan, during the period of July 21-30, 1994. The survey team measured the terrestrial gamma radiation at selected areas on the site to determine the levels of natural and man-made radiation. The survey was part of a cooperative effort between the United States team and teams of radiation scientists from the National Nuclear Center of the Republic of Kazakhstan and the V.G. Khlopin Radium Institute in St. Petersburg, Russia. In addition to in situ radiation measurements made by the United States and Russian teams, soil samples were collected and analyzed by the Russian and Kazakhstani teams. All teams conducted their measurements at ten locations within the test site. The United States team also made a number of additional measurements to locate and verify the positions of three potential fallout plumes containing plutonium contamination from nonnuclear tests. In addition, the United States team made several measurements in Kurchatov City, the housing area used by personnel and their families who work(ed) at the test sites. Comparisons between the United States and Russian in situ measurements and the soil sample results are presented as well as comparisons with a Soviet aerial survey conducted in 1990-1991. The agreement between the different types of measurements made by all three countries was quite good

  19. On Dimensions of OTA Setups for Massive MIMO Base Stations Radiated Testing

    DEFF Research Database (Denmark)

    Kyösti, Pekka; Fan, Wei; Pedersen, Gert F.

    2016-01-01

    The development of base stations (BS) with large aperture antenna arrays, enabled partially by the utilization of cmWave and mmWave frequency bands, will require radiated testing in fading conditions. In this paper, the objective is to investigate the suitable measurement distances and physical...

  20. Radiation testing of thick-wall objects using a linear accelerator or Co-60

    International Nuclear Information System (INIS)

    Depending on the energy required, a 60 Co source or various types of betatrons and linear accelerators may be used for radiation testing of thick-walled metal parts. While 60 Co sources are easily transported, accelerators are not, but a transportable linear accelerator is described

  1. Eurados trial performance test for personal dosemeters for external beta radiation

    DEFF Research Database (Denmark)

    Christensen, P.; Bordy, J.M.; Ambrosi, P.

    2001-01-01

    On the initiative of the European Dosimetry Group (EURADOS) action group 'Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation' a trial performance test for whole-body and extremity personal dosemeters broadly representative of those in use in the EU...... the results obtained from the exercise. In particular, based on the replies to a questionnaire issued to each participant, the results are analysed in relation to important design characteristics of the dosemeters taking part in the test....

  2. A critical experimental test of synchrotron radiation theory with 3rd generation light source

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2016-05-15

    A recent ''beam splitting'' experiment at LCLS apparently demonstrated that after a microbunched electron beam is kicked on a large angle compared to the divergence of the FEL radiation, the microbunching wave front is readjusted along the new direction of motion of the kicked beam. Therefore, coherent radiation from an undulator placed after the kicker is emitted along the kicked direction without suppression. This strong emission of coherent undulator radiation in the kicked direction cannot be explained in the framework of conventional synchrotron radiation theory. In a previous paper we explained this puzzle. We demonstrated that, in accelerator physics, the coupling of fields and particles is based, on the one hand, on the use of results from particle dynamics treated according to the absolute time convention and, on the other hand, on the use of Maxwell equations treated according to the standard (Einstein) synchronization convention. Here lies the misconception which led to the strong qualitative disagreement between theory and experiment. After the ''beam splitting'' experiment at LCLS, it became clear that the conventional theory of synchrotron radiation cannot ensure the correct description of coherent and spontaneous emission from a kicked electron beam, nor the emission from a beam with finite angular divergence, in an undulator or a bending magnet. However, this result requires further experimental confirmation. In this publication we propose an uncomplicated and inexpensive experiment to test synchrotron radiation theory at 3rd generation light sources.

  3. A critical experimental test of synchrotron radiation theory with 3rd generation light source

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2016-05-01

    A recent ''beam splitting'' experiment at LCLS apparently demonstrated that after a microbunched electron beam is kicked on a large angle compared to the divergence of the FEL radiation, the microbunching wave front is readjusted along the new direction of motion of the kicked beam. Therefore, coherent radiation from an undulator placed after the kicker is emitted along the kicked direction without suppression. This strong emission of coherent undulator radiation in the kicked direction cannot be explained in the framework of conventional synchrotron radiation theory. In a previous paper we explained this puzzle. We demonstrated that, in accelerator physics, the coupling of fields and particles is based, on the one hand, on the use of results from particle dynamics treated according to the absolute time convention and, on the other hand, on the use of Maxwell equations treated according to the standard (Einstein) synchronization convention. Here lies the misconception which led to the strong qualitative disagreement between theory and experiment. After the ''beam splitting'' experiment at LCLS, it became clear that the conventional theory of synchrotron radiation cannot ensure the correct description of coherent and spontaneous emission from a kicked electron beam, nor the emission from a beam with finite angular divergence, in an undulator or a bending magnet. However, this result requires further experimental confirmation. In this publication we propose an uncomplicated and inexpensive experiment to test synchrotron radiation theory at 3rd generation light sources.

  4. Development and Testing of a Shape Memory Alloy-Driven Composite Morphing Radiator

    Science.gov (United States)

    Walgren, P.; Bertagne, C.; Wescott, M.; Benafan, O.; Erickson, L.; Whitcomb, J.; Hartl, D.

    2018-01-01

    Future crewed deep space missions will require thermal control systems that can accommodate larger fluctuations in temperature and heat rejection loads than current designs. To maintain the crew cabin at habitable temperatures throughout the entire mission profile, radiators will be required to exhibit turndown ratios (defined as the ratio between the maximum and minimum heat rejection rates) as high as 12:1. Potential solutions to increase radiator turndown ratios include designs that vary the heat rejection rate by changing shape, hence changing the rate of radiation to space. Shape memory alloys exhibit thermally driven phase transformations and thus can be used for both the control and actuation of such a morphing radiator with a single active structural component that transduces thermal energy into motion. This work focuses on designing a high-performance composite radiator panel and investigating the behavior of various SMA actuators in this application. Three designs were fabricated and subsequently tested in a relevant thermal vacuum environment; all three exhibited repeatable morphing behavior, and it is shown through validated computational analysis that the morphing radiator concept can achieve a turndown ratio of 27:1 with a number of simple configuration changes.

  5. Development and Testing of a Shape Memory Alloy-Driven Composite Morphing Radiator

    Science.gov (United States)

    Walgren, P.; Bertagne, C.; Wescott, M.; Benafan, O.; Erickson, L.; Whitcomb, J.; Hartl, D.

    2018-03-01

    Future crewed deep space missions will require thermal control systems that can accommodate larger fluctuations in temperature and heat rejection loads than current designs. To maintain the crew cabin at habitable temperatures throughout the entire mission profile, radiators will be required to exhibit turndown ratios (defined as the ratio between the maximum and minimum heat rejection rates) as high as 12:1. Potential solutions to increase radiator turndown ratios include designs that vary the heat rejection rate by changing shape, hence changing the rate of radiation to space. Shape memory alloys exhibit thermally driven phase transformations and thus can be used for both the control and actuation of such a morphing radiator with a single active structural component that transduces thermal energy into motion. This work focuses on designing a high-performance composite radiator panel and investigating the behavior of various SMA actuators in this application. Three designs were fabricated and subsequently tested in a relevant thermal vacuum environment; all three exhibited repeatable morphing behavior, and it is shown through validated computational analysis that the morphing radiator concept can achieve a turndown ratio of 27:1 with a number of simple configuration changes.

  6. Measurement protocols for performance testing of dosimetry services for external radiations

    International Nuclear Information System (INIS)

    1993-01-01

    In the Health and Safety Executive's ''Requirements for the Approval of Dosimetry Services under the Ionising Radiations Regulations 1985'', it is stipulated that dosimetry services seeking approval must show that they have successfully completed a performance test. The services must arrange for the tests to be carried out on application and thereafter every 18 months, by a laboratory which has received accreditation from the National Measurement Accreditation Service (NAMAS) for the whole performance testing activity. The performance tests must be carried out to published protocols and the purpose here is to provide protocols for external, whole body film and TLD dosimetry services, and for skin and extremity dosimetry services. (Author)

  7. Retinal, optic nerve and chiasmal function following radiation therapy demonstrated by visual evoked response testing

    International Nuclear Information System (INIS)

    Soni, A.B.; Constine, L.S.; Smith, D.; Palisca, M.; Ojomo, K.; Muhs, A.

    1997-01-01

    Purpose: To evaluate the tolerance of the retina, optic nerve, and optic chiasm to radiation doses conventionally used to treat patients with primary brain or pituitary tumors and to explore the character of detectable radiation effects. Visual evoked response (VER) testing is a noninvasive and sensitive method for identifying radiation injury to the visual system due to alterations in small vessel or myelin integrity. Such evaluations may increase our understanding of the threshold for and the pathogenesis of radiation injury. Materials and Methods: Twenty-four patients irradiated for brain or pituitary tumors between 1972 and 1996 had VER testing. Patients were included in study if the retina, optic nerves or chiasm were in the radiation (RT) field. At the time of RT patients ranged in age from 1.5 to 55 years (median 33). Mean doses were as follows: right retina, 29 Gy (range 10 - 60 Gy); left retina, 29.5 Gy (range 10 - 60 Gy); right optic nerve, 42.9 Gy (range 10 - 60 Gy); left optic nerve, 42.6 Gy (range 10 - 60 Gy); and optic chiasm, 48.2 Gy (range 10 - 65 Gy). Daily fractionation ranged from 1.5 to 1.8 Gy. Pattern VER testing distinguishes compressive or ischemic effects of tumor on the visual system from radiation retinopathy or optic neuropathy on the basis of the conduction amplitude and delay pattern. Prechiasm, chiasm, and postchiasm injuries are distinguishable by analyzing VER changes. Four evoked responses were obtained for each eye, each representing the average of 100 stimulus reversals. Results: VER was normal in 11 patients and abnormal in 13 patients. Only 2 patients (8%) had VER evidence of radiation injury to the visual system, one of whom had visual compromise. The other 11 abnormal patients had characteristic VER changes attributable to tumor or surgical damage. There was no significant difference in the radiation doses given to any subgroup. The one patient with radiation retinopathy had received 55-60 Gy to the posterior globe. Ten years

  8. Solar panel thermal cycling testing by solar simulation and infrared radiation methods

    Science.gov (United States)

    Nuss, H. E.

    1980-01-01

    For the solar panels of the European Space Agency (ESA) satellites OTS/MAROTS and ECS/MARECS the thermal cycling tests were performed by using solar simulation methods. The performance data of two different solar simulators used and the thermal test results are described. The solar simulation thermal cycling tests for the ECS/MARECS solar panels were carried out with the aid of a rotatable multipanel test rig by which simultaneous testing of three solar panels was possible. As an alternative thermal test method, the capability of an infrared radiation method was studied and infrared simulation tests for the ultralight panel and the INTELSAT 5 solar panels were performed. The setup and the characteristics of the infrared radiation unit using a quartz lamp array of approx. 15 sq and LN2-cooled shutter and the thermal test results are presented. The irradiation uniformity, the solar panel temperature distribution, temperature changing rates for both test methods are compared. Results indicate the infrared simulation is an effective solar panel thermal testing method.

  9. Comparison of proton microbeam and gamma irradiation for the radiation hardness testing of silicon PIN diodes

    Science.gov (United States)

    Jakšić, M.; Grilj, V.; Skukan, N.; Majer, M.; Jung, H. K.; Kim, J. Y.; Lee, N. H.

    2013-09-01

    Simple and cost-effective solutions using Si PIN diodes as detectors are presently utilized in various radiation-related applications in which excessive exposure to radiation degrades their charge transport properties. One of the conventional methods for the radiation hardness testing of such devices is time-consuming irradiation with electron beam or gamma-ray irradiation facilities, high-energy proton accelerators, or with neutrons from research reactors. Recently, for the purpose of radiation hardness testing, a much faster nuclear microprobe based approach utilizing proton irradiation has been developed. To compare the two different irradiation techniques, silicon PIN diodes have been irradiated with a Co-60 gamma radiation source and with a 6 MeV proton microbeam. The signal degradation in the silicon PIN diodes for both irradiation conditions has been probed by the IBIC (ion beam induced charge) technique, which can precisely monitor changes in charge collection efficiency. The results presented are reviewed on the basis of displacement damage calculations and NIEL (non-ionizing energy loss) concept.

  10. BARTTest: Community-Standard Atmospheric Radiative-Transfer and Retrieval Tests

    Science.gov (United States)

    Harrington, Joseph; Himes, Michael D.; Cubillos, Patricio E.; Blecic, Jasmina; Challener, Ryan C.

    2018-01-01

    Atmospheric radiative transfer (RT) codes are used both to predict planetary and brown-dwarf spectra and in retrieval algorithms to infer atmospheric chemistry, clouds, and thermal structure from observations. Observational plans, theoretical models, and scientific results depend on the correctness of these calculations. Yet, the calculations are complex and the codes implementing them are often written without modern software-verification techniques. The community needs a suite of test calculations with analytically, numerically, or at least community-verified results. We therefore present the Bayesian Atmospheric Radiative Transfer Test Suite, or BARTTest. BARTTest has four categories of tests: analytically verified RT tests of simple atmospheres (single line in single layer, line blends, saturation, isothermal, multiple line-list combination, etc.), community-verified RT tests of complex atmospheres, synthetic retrieval tests on simulated data with known answers, and community-verified real-data retrieval tests.BARTTest is open-source software intended for community use and further development. It is available at https://github.com/ExOSPORTS/BARTTest. We propose this test suite as a standard for verifying atmospheric RT and retrieval codes, analogous to the Held-Suarez test for general circulation models. This work was supported by NASA Planetary Atmospheres grant NX12AI69G, NASA Astrophysics Data Analysis Program grant NNX13AF38G, and NASA Exoplanets Research Program grant NNX17AB62G.

  11. Radiative transfer with finite elements. Pt. 1. Basic method and tests

    Energy Technology Data Exchange (ETDEWEB)

    Richling, S. [Heidelberg Univ. (Germany). Inst. fuer Theoretische Astrophysik; Meinkoehn, E. [Heidelberg Univ. (Germany). Inst. fuer Theoretische Astrophysik]|[Heidelberg Univ. (Germany). Inst. fuer Angewandte Mathematik; Kryzhevoi, N. [Heidelberg Univ. (Germany). Inst. fuer Theoretische Astrophysik]|[Heidelberg Univ. (DE). Interdisziplinaeres Zentrum fuer Wissenschaftliches Rechnen (IWR); Kanschat, G. [Heidelberg Univ. (Germany). Inst. fuer Angewandte Mathematik]|[Heidelberg Univ. (DE). Interdisziplinaeres Zentrum fuer Wissenschaftliches Rechnen (IWR)

    2001-10-01

    A finite element method for solving the monochromatic radiation transfer equation including scattering in three dimensions is presented. The algorithm employs unstructured grids which are adaptively refined. Adaptivity as well as ordinate parallelization reduce memory requirements and execution time and make it possible to calculate the radiation field across several length scales for objects with strong opacity gradients. An a posteriori error estimate for one particular quantity is obtained by solving the dual problem. The application to a sample of test problems reveals the properties of the implementation. (orig.)

  12. Instrumentation measurement and testing complex for detection and identification of radioactive materials using the emitted radiation

    International Nuclear Information System (INIS)

    Samossadny, V.T.; Dmitrenko, V.V.; Kadlin, V.V.; Kolesnikov, S.V.; Ulin, S.E.; Grachev, V.M.; Vlasik, K.F.; Dedenko, G.L.; Novikov, D.V.; Uteshev, Z.M.

    2006-01-01

    Simultaneous measurement of neutron and gamma radiation is a very usefull method for effective nuclear materials identification and control. The gamma-ray-neutron complex described in the paper is based on two multi-layer 3 He neutrons detectors and two High Pressure Xenon gamma-ray spectrometers assembled in one unit. All these detectors were callibrated on neutron and gamma-ray sources. The main characteristics of the instrumentation , its testing results and gamma-ray and neutron radiation parameters, which have been measured are represented in the paper. The gamma-neutron sources and fissile materials reliable detection and identification capability was demonstrated

  13. Environmental radiation at the Monte Bello Islands from nuclear weapons tests conducted in 1952 and 1956

    International Nuclear Information System (INIS)

    Moroney, J.R.; Cooper, M.B.

    1982-12-01

    The results from the 1962 and 1968 surveys of environmental radiation at the Monte Bello Islands are presented. These were the first of the series of surveys of radioactive contamination of the Islands to be carried out following nuclear weapons tests conducted in 1952 and 1956. Detailed comparison is made with the results obtained in the subsequent surveys in 1972 and 1978. For more than 20 years, no area at the Monte Bello Islands has presented an acute hazard due to external exposure to environmental radiation

  14. Gamma radiation grafted polymers for immobilization of Brucella antigen in diagnostic test studies

    Science.gov (United States)

    Docters, E. H.; Smolko, E. E.; Suarez, C. E.

    The radiation grafting process has a wide field of industrial applications, and in the recent years the immobilization of biocomponents in grafted polymeric materials obtained by means of ionizing radiations is a new and important contribution to biotechnology. In the present work, gamma preirradiation grafting method was employed to produce acrylics hydrogels onto polyethylene (PE), polyvinyl chloride (PVC) and polystyrene (PS). Two monomers were used to graft the previously mentioned polymers: methacrylic acid (MAAc) and acrylamide (AAm), and several working conditions were considered as influencing the degree of grafting. All this grafted polymers were used to study the possibility of a subsequent immobilization of Brucella antigen (BAg) in diagnostic test studies (ELISA).

  15. Gamma radiation grafted polymers for immobilization of Brucella antigen in diagnostic test studies

    International Nuclear Information System (INIS)

    Docters, E.H.; Smolko, E.E.

    1990-01-01

    The radiation grafting process has a wide field of industrial applications, and in the recent years the immobilization of biocomponents in grafted polymeric materials obtained by means of ionizing radiations is a new and important contribution to biotechnology. In the present work, gamma preirradiation grafting method was employed to produce acrylics hydrogels onto polyethylene (PE), polyvinyl chloride (PVC) and polystyrene (PS). Two monomers were used to graft the previously mentioned polymers: methacrylic acid (MAAc) and acrylamide (AAm), and several working conditions were considered as influencing the degree of grafting. All these grafted polymers were used to study the possibility of a subsequent immobilization of Brucella antigen (BAg) in diagnostic test studies (ELISA). (author)

  16. Evaluation gamma radiation in composite sisal fiber- polyurethane derived of castor oil by bending test

    International Nuclear Information System (INIS)

    Souza, Felipe H. de; Geraldo, Ricardo R.; Vasco, Marina C.; Azevedo, Elaine; Claro Neto, Salvador

    2015-01-01

    Materials used for making furniture and accessories or positioning in X -ray examination rooms should not exhale volatile organic compounds and are resistant to ionizing radiation. One solution is the use of vegetable fiber and polyurethane composites of vegetable origin, since they are biodegradable, derived from renewable raw materials and have no volatile organic compounds. The main difficulty in developing this material is fiber adhesion with the polymer. The objective of this study is to evaluate the mechanical properties of composite sisal fiber composite, without further treatment, and polyurethane derived from castor oil, with a dose of 25 kGy gamma radiation, subjected to 3 points bending tests. (author)

  17. Gamma radiation grafted polymers for immobilization of Brucella antigen in diagnostic test studies

    Energy Technology Data Exchange (ETDEWEB)

    Docters, E H; Smolko, E E [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Direccion de Radioisotopos y Radiaciones; Suarez, C E [Instituto Nacional de Tecnologia Agropecuaria, Castelar (Argentina)

    1990-01-01

    The radiation grafting process has a wide field of industrial applications, and in the recent years the immobilization of biocomponents in grafted polymeric materials obtained by means of ionizing radiations is a new and important contribution to biotechnology. In the present work, gamma preirradiation grafting method was employed to produce acrylics hydrogels onto polyethylene (PE), polyvinyl chloride (PVC) and polystyrene (PS). Two monomers were used to graft the previously mentioned polymers: methacrylic acid (MAAc) and acrylamide (AAm), and several working conditions were considered as influencing the degree of grafting. All these grafted polymers were used to study the possibility of a subsequent immobilization of Brucella antigen (BAg) in diagnostic test studies (ELISA). (author).

  18. Isotope detectors and radiation detectors for test reliability techniqui. A preliminary project

    International Nuclear Information System (INIS)

    Christell, R.

    1977-03-01

    A survey is done of small and simple components for use as detectors for ionizing radiation, as well as different methods and components producing images of radiation fields based on position sensitive detectors. The investigation has resulted in a system for detection of stones in wood. In a second project isotope excited x ray fluorescence has been used for analysis of material resulting from wear of mechanical components. A facility for analysis has been built and test analysis has been performed. Methods for continous wear control with possibility to forecast breakdowns have been investigated. (K.K.)

  19. Radiation resistance of polymer materials. Degradation evaluation by accelerated testing for application condition

    International Nuclear Information System (INIS)

    Seguchi, Tadao; Tamura, Kiyotoshi; Sorimachi, Masami

    2010-02-01

    This paper presents re-evaluated radiation resistance property data of polymer materials, which had been tested in past times in TAKASAKI Quantum Beam Science Directorate, for the future study of ageing evaluation of low voltage electric cable insulation materials used in light-water nuclear reactors. The radiation resistance of 25 types of plastics and rubbers materials applied in practical environments was evaluated by the accelerated testing of gamma-ray irradiation under oxygen pressure, and was compared with the radiation resistance determined from the traditional testing by irradiation with a high dose rate in air. The polymer materials were formulated to be similar or equivalent to practical materials, and the most of formulation (chemical compounds and quantities) were described. For all materials, the tensile properties (elongation at break, ultimate strength, 100% or 200% modulus), electric resistivity, gel-fraction, and density were measured after irradiation in oxidation conditions and irradiation in air with a high dose rate (non-oxidation conditions). The data of relations between each properties and total dose at various conditions were compiled, and the relations among the changes of mechanical properties, electrical properties, and radiation induced chemical reactions were discussed. (author)

  20. Beam and radiation tests of a fast, warm liquid open-quotes swimming poolclose quotes calorimeter

    International Nuclear Information System (INIS)

    Kadyk, J.

    1993-09-01

    A fast, warm liquid calorimeter module with lead absorber immersed in tetramethyl pentane (TMP) as the liquid medium (i.e. a open-quotes swimming poolclose quotes configuration) has been built and tested in a high energy beam at FNAL, and exposed to intense radiation from a strong Co 60 source. A two-tower prototype, incorporating the concept of the electrostatic transformer for fast readout, exhibited very good uniformity and small cross-talk in the beam test. This same calorimeter was exposed to over 10 Mrad of radiation from the Co 60 source, and the electron drift lifetime was measured as a function of accumulated dose. The lifetime improved significantly with small doses of radiation, up to a few hundred krad, then decreased gradually at higher doses, and extrapolated to a minimum useful lifetime of 0.1 μs at over 150 Mrad. This result was confirmed by measurements on a small single-electrode test cell which was irradiated to more than 25 Mrad. In this case, the lifetime decreased from 10μs to 0.1 μs when extrapolated to a dose of over 600 Mrad. This cell was also used to measure the effect of positive ion open-quotes space chargeclose quotes buildup under intense radiation. The results suggest that such effects are small even at the highest intensity available, about 1.3 Mrad/day, for applied fields ≥25 kV/cm

  1. Radiation consequences of combatant radioactive substances tests on the Semipalatinsk Test Site

    International Nuclear Information System (INIS)

    Strilchuk, Yu.G.; Osintsev, A.Yu.; Kuzin, D.E.; Bryantseva, N.V.; Bozhko, V.V.; Tonevitskaya, O.V.; Panitskaya, D.S.; Lukashenko, S.N.; Georgievskij, V.; Murley, R.; Wells, D.

    2008-01-01

    Nuclear explosions were not the only type of tests carried out on the STS territory. In 1953 - 1957 the STS territory was the area of testing of combatant radioactive substances (CRS). Combatant radioactive substances were liquid or powder-like combatment radioactive mixtures manufactured either from the wastes of radiochemical industry or by neutron irradiation of specally selected substances in nuclear reactor. Their specific activity ranged from tenths of Curie to several Curie per liter. CRS tests were made on testing grounds ''4'' and ''4A'' situated near northern outpost beyond the Opytnoye Pole (Experimental field). Dispersion of CRS was achieved by blasting of individual shells, bombardment of the area by mortar shells, bombardment from aircraft bombers or dispersion of CRS from airplanes. Investigations carried out in the past years on the territory of the testing grounds discovered fragments of metal products used in the CRS tests and over 30 areas of local radioactive contamination. 90 Sr was the main radioactive pollutant, whose specific activity in upper soil is as high as 5*10 8 Bq/kg; other radionuclides are presented by isotopes: 239+240 Pu, 152 Eu, 154 Eu, 137 Cs, 241 Am, 60 Co. The areas of radioactively-contaminated soil range from hundreds to hundreds of thousands of square meters with some of them expanding to distances of several kilometers. Concentration of radionuclides in soil and vegetation may be compared with that of radioactive waste

  2. PSA Solar furnace: A facility for testing PV cells under concentrated solar radiation

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Reche, J.; Canadas, I.; Sanchez, M.; Ballestrin, J.; Yebra, L.; Monterreal, R.; Rodriguez, J.; Garcia, G. [Concentration Solar Technologies, Plataforma Solar de Almeria-CIEMAT P.O. Box 22, Tabernas, E-04200 (Almeria) (Spain); Alonso, M.; Chenlo, F. [Photovoltaic Components and Systems, Renewable Energies Department-CIEMAT Avda. Complutense, 22, Madrid, E-28040 (Spain)

    2006-09-22

    The Plataforma Solar de Almeria (PSA), the largest centre for research, development and testing of concentration solar thermal technologies in Europe, has started to apply its knowledge, facilities and resources to development of the Concentration PV technology in an EU-funded project HiConPV. A facility for testing PV cells under solar radiation concentrated up to 2000x has recently been completed. The advantages of this facility are that, since it is illuminated by solar radiation, it is possible to obtain the appropriate cell spectral response directly, and the flash tests can be combined with prolonged PV-cell irradiation on large surfaces (up to 150cm{sup 2}), so the thermal response of the PV cell can be evaluated simultaneously. (author)

  3. Failure modes induced by natural radiation environments on DRAM memories: study, test methodology and mitigation technique

    International Nuclear Information System (INIS)

    Bougerol, A.

    2011-05-01

    DRAMs are frequently used in space and aeronautic systems. Their sensitivity to cosmic radiations have to be known in order to satisfy reliability requirements for critical applications. These evaluations are traditionally done with particle accelerators. However, devices become more complex with technology integration. Therefore new effects appear, inducing longer and more expensive tests. There is a complementary solution: the pulsed laser, which triggers similar effects as particles. Thanks to these two test tools, main DRAM radiation failure modes were studied: SEUs (Single Event Upset) in memory blocks, and SEFIs (Single Event Functional Interrupt) in peripheral circuits. This work demonstrates the influence of test patterns on SEU and SEFI sensitivities depending on technology used. In addition, this study identifies the origin of the most frequent type of SEFIs. Moreover, laser techniques were developed to quantify sensitive surfaces of the different effects. This work led to a new test methodology for industry, in order to optimize test cost and efficiency using both pulsed laser beams and particle accelerators. Finally, a new fault tolerant technique is proposed: based on DRAM cell radiation immunity when discharged, this technique allows to correct all bits of a logic word. (author)

  4. Morbidité et mortalité des AVC chez le diabétique au CHU de Lomé ...

    African Journals Online (AJOL)

    Méthode : étude prospective portant sur 105 sujets aux CHU Tokoin et Campus en septembre-octobre 2004. Résultats : la maladie est un malheur pour l'individu (90,48%). La médecine conventionnelle ne donne pas totale satisfaction à ses clients, et la médecine religieuse est une suppléance à la médecine traditionnelle ...

  5. Radiation tests on selected electrical insulating materials for high-power and high voltage application

    International Nuclear Information System (INIS)

    Liptak, G.; Schuler, R.; Haberthuer, B.; Mueller, H.; Zeier, W.; Maier, P.; Schoenbacher, H.

    1985-01-01

    This report presents a comprehensive set of test results on the irradiation of insulating materials and systems used for the windings of rotating machines, dry-type transformers, and magnet coils. The materials were: Novolac, bisphenol-A, and cycloaliphatic types of epoxy; saturated and unsaturated polyesterimide; silicone, phenolic, and acrylic resins. The reinforcement consisted of glass mat, glass roving, glass cloth, mica paper, polyester mat, polyester roving, polyester cloth, aromatic polyamide paper, or combinations thereof. The materials were irradiated in an 8 MW pool reactor up to integrated doses of 10 8 Gy. On most samples, flexural properties were examined as recommended by IEC Standard 544. For tapes and varnishes, the breakdown voltage was measured. The adhesion of copper bars glued together with an epoxy resin was examined by means of a lap-shear test. A cupping test by means of the Erichsen apparatus was used to measure the flexibility of varnishes. The results are presented in tables and graphs for each of the materials tested. Those from mechanical tests show that the radiation resistance of composite resin-rich insulations depends not only on the base resin combination and the reinforcement material but, to a large degree, also on the adhesion between the two. It appears that better adhesion, and consequently higher radiation resistance, is obtained by special surface treatments of glass fibres. For laminates, higher radiation resistance is obtained with glass mat and resin combinations than with glass cloth as reinforcing materials. The breakdown voltage tests show that the application of mechanical stress to most irradiated samples causes the insulation layer to crack, resulting in lower dielectric strength. For a number of materials, the critical properties of flexural strength and breakdown voltage are above 50% of the initial value at doses between 10 7 and 10 8 Gy, i.e. a radiation index of 7 to 8 at 10 5 Gy/h. (orig.)

  6. Explanation of test and assessment of chromosomal aberrations on occupational health examinations for radiation workers

    International Nuclear Information System (INIS)

    Lu Yumin; Fu Baohua; Han Lin; Wang Xi'ai; Zhao Fengling

    2012-01-01

    Test and Assessment of Chromosomal Aberrations on Occupational Health Examinations for Radiation Workers was formulated for standardizing analysis and outcome assessment of chromosomal aberrations on occupational health examinations for radiation workers. In order to provide experimental and theoretical basis for implementation and extension of this standard, this paper interpreted the standard comprehensively, including some existed problems that methods on detection and outcome assessment of chromosomal aberrations is not unified in different laboratories in China, and related criteria,laws and regulations at home and abroad are not fit for the detection of chromosomal aberrations for radiation workers very well; some introduction on methods of chromosomal slide preparation, discriminant analysis and outcome assessment of chromosomal aberration; and some influencing factors in the quality of chromosomal aberration detection. (authors)

  7. Design and radiation tests on a LED based emergency evacuation directional lighting

    CERN Document Server

    Trikoupis, Nikolaos

    2017-01-01

    A LED (Light Emitting Diode) based directional lighting system has been designed to indicate the best evacuation direction for applications like the Large Hadron Collider (LHC) tunnel. The design includes constraints for redundancy required by safety systems and for components selection by radiation effects. Most of the literature for radiation effects on LEDs concern digital communications systems, although some recent reports do exist for visible spectrum power LEDs and the reduction in light output versus dose is coherent with the results presented in this paper. Prototype lighting units were irradiated in CERN’s CHARM facility up to a Total Integrated Dose (TID) of 870 Gy and no failures were observed. This paper describes the basic design, presents field tests and the effects of radiation on the LEDs luminance.

  8. Radiation hardness tests of SiPMs for the JLab Hall D Barrel calorimeter

    International Nuclear Information System (INIS)

    Qiang, Yi; Zorn, Carl; Barbosa, Fernando; Smith, Elton

    2013-01-01

    We report on the measurement of the neutron radiation hardness of silicon photomultipliers (SiPMs) manufactured by Hamamatsu Corporation in Japan and SensL in Ireland. Samples from both companies were irradiated by neutrons created by a 1 GeV electron beam hitting a thin lead target at Jefferson Lab Hall A. More tests regarding the temperature dependence of the neutron radiation damage and self-annealing were performed on Hamamatsu SiPMs using a calibrated Am–Be neutron source from the Jefferson Lab Radiation Control group. As the result of irradiation both dark current and dark rate increase linearly as a function of the 1 MeV equivalent neutron fluence and a temperature dependent self-annealing effect is observed.

  9. Plan for the testing of radiation measurement instrumentation intended for use at an excavation site

    International Nuclear Information System (INIS)

    Gehrke, R.J.

    1994-11-01

    This plan describes performance tests to be made with ionizing radiation measurement instrumentation designed and built for in-field assay at an excavation site. One instrument measures gross gamma-ray and neutron fields and the other identifies gamma-ray emitting radionuclides and also is capable of assaying for selected hazardous materials. These instruments will be operationally tested to verify that original specifications have been met and performance tested to establish and verify that they have the potential to function as intended at an excavation site

  10. Physicians' knowledge about radiation dose and possible risks of common medical tests: a survey in Iran

    International Nuclear Information System (INIS)

    Zakeri, Farideh; Mianji, Fereidoun; Shakeri, Mahsa; Rajabpour, Mohammad Reza; Farshidpour, Mohammad Reza

    2016-01-01

    Recent data suggest that knowledge of radiation exposures among physicians is inadequate. This study, therefore, aimed to evaluate their knowledge of the radiation doses their patients received and awareness of associated biological risks of radiation exposure. A questionnaire in multiple-choice format consisted of four sections with a total of 10 questions based on the literature review. A total of 136 questionnaires were returned from 69 general practitioners and 67 physicians in various specialties from 10 different hospitals in the capital city of Tehran, Iran. Fifty-four percent of general practitioners and twenty-five percent of specialties declared that they are not aware of biological risks of radiation exposure. Fifty-six percent of physicians did not know the correct definition of absorbed dose. Only 33% of physicians knew the dose exposure of a chest X-ray and only 31% knew the approximate doses of various procedures relative to a chest X-ray. Forty-seven percent of physicians incorrectly distinguished the stochastic effects of radiation from the deterministic effects, and thirty-eight of physicians did not know the organs of the body that are most sensitive to ionizing radiation. Only 23.5% of physicians were aware of the one in 2000 risk of induction of fatal carcinoma from computed tomography of the abdomen. Seventy-nine percent of physicians incorrectly underestimated the contribution of nuclear and radiological tests in exposure of an average person. The mean score of the specialties trended toward being more accurate than general practitioners (4.18 ± 1.28 vs. 3.89 ± 1.46, respectively, from a potential accurate total score of 9), but these differences were not statistically significant. Among specialists, orthopedics had the highest scores. The present study demonstrated the limited knowledge of radiation exposures among general practitioners and specialists and a need to improve their knowledge by means of targeted training and re

  11. Tests of the linearity assumption in the dose-effect relationship for radiation-induced cancer

    International Nuclear Information System (INIS)

    Cohen, A.F.; Cohen, B.L.

    1978-01-01

    The validity of the BEIR linear extrapolation to low doses of the dose-effect relationship for radiation induced cancer is tested by use of natural radiation making use of selectivity on type of cancer, sex, age group, geographic area, and time period. For lung cancer, a linear interpolation between zero dose-zero effect and the data from radon-induced cancers in miners over-estimates the total number of observed lung cancers in many countries in the early years of this century; the discrepancy is substantially increased if the 30-44 year age range and/or if only females are considered, and by the fact that many other causes of lung cancer are shown to have been important at that time. The degree to which changes of diagnostic efficiency with time can influence the analysis is considered at some length. It is concluded that the linear relationship substantially over-estimates effects of low radiation doses. A similar analysis is applied to leukemia induced by natural radiation, applying selectivity by age, sex, natural background level, and date, and considering other causes. It is concluded that effects substantially larger than those obtained from linear extrapolation are excluded. The use of the selectivities mentioned above is justified by the fact that the incidence of cancer or leukemia is an upper limit on the rate at which it is caused by radiation effects; in determining upper limits it is justifiable to select situations which minimize it. (author)

  12. Radiation impact on the characteristics of optical glasses test results on a selected set of materials

    Science.gov (United States)

    Fruit, Michel; Gussarov, Andrei; Berghmans, Francis; Doyle, Dominic; Ulbrich, Gerd

    2017-11-01

    It is well known within the Space optics community that radiation may significantly affect transmittance of glasses. To overcome this drawback, glass manufacturers have developed Cerium doped counterparts of classical glasses. This doped glasses display much less transmittance sensitivity to radiation. Still, the impact of radiation on refractive index is less known and may affect indifferently classical or Cerium doped glasses. ESTEC has initialised an R&D program with the aim of establishing a comprehensive data base gathering radiation sensitivity data, called Dose coefficients, for all the glass optical parameters (transmittance / refractive index / compaction……). The first part of this study, to define the methodology for such a data base, is run by ASTRIUM SAS in co-operation with SCK CEN. This covers theoretical studies associated to testing of a selected set of classical and "radiation hardened" glasses. It is proposed here to present first the theoretical backgrounds of this study and then to give results which have been obtained so far.

  13. Actual questions of radiographic testing and radiation protection. Contributions; Aktuelle Fragen der Durchstrahlungspruefung und des Strahlenschutzes. Beitraege

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2017-08-01

    The proceedings of the 17th DGZfP seminar include nine contributions on the use of radiography for periodic non destructive testing purposes and issues of radiation protection for the testing personnel and the security of radioactive materials.

  14. Irradiation tests of radiation resistance optical fibers for fusion diagnostic application

    Science.gov (United States)

    Kakuta, Tsunemi; Shikama, Tatsuo; Nishitani, Takeo; Yamamoto, Shin; Nagata, Shinji; Tsuchiya, Bun; Toh, Kentaro; Hori, Junichi

    2002-11-01

    To promote development of radiation-resistant core optical fibers, the ITER-EDA (International Thermonuclear Experimental Reactor-Engineering Design Activity) recommended carrying out international round-robin irradiation tests of optical fibers to establish a reliable database for their applications in the ITER plasma diagnostics. Ten developed optical fibers were irradiation-tested in a Co-60 gamma cell, a Japan Materials Testing Reactor (JMTR). Also, some of them were irradiation tested in a fast neutron irradiation facility of FNS (Fast Neutron Source), especially to study temperature dependence of neutron-associated irradiation effects. Included were several Japanese fluorine doped fibers and one Japanese standard fiber (purified and undoped silica core), as well as seven Russian fibers. Some of Russian fibers were drawn by Japanese manufactures from Russian made pre-form rods to study effects of manufacturing processes to radiation resistant properties. The present paper will describe behaviors of growth of radiation-induced optical transmission loss in the wavelength range of 350-1750nm. Results indicate that role of displacement damages by fast neutrons are very important in introducing permanent optical transmission loss. Spectra of optical transmission loss in visible range will depend on irradiation temperatures and material parameters of optical fibers.

  15. Radiation-related monitoring and environmental research at the Nevada Test Site

    International Nuclear Information System (INIS)

    Anspaugh, L.R.; Patton, S.E.; Shinn, J.H.; Black, S.C.; Costa, C.F.; Elle, D.R.; Essington, E.H.; Gilbert, R.O.; Gonzalez, D.A.; Hunter, R.B.; Medica, P.A.; McArthur, R.D.; Thompson, C.B.; O'Farrell, T.P.; Romney, E.M.

    1990-01-01

    Beginning with the first nuclear-weapons-related tests at the Nevada Test Site (NTS) in 1951, a radiation-related monitoring program was established to determine the levels and distribution of radionuclides released. Primary methods involved survey-meter-equipped field-monitoring teams and placement of film badges and air-sampling devices at fixed locations. Beginning in the mid-1950s, more stringent standards, the results of this monitoring program, and the results of related research programs led to increased engineering efforts to reduce local fallout. With passage of the National Environmental Policy Act and increased concern about possible effects of radiation exposure, environmental activities related to the NTS increased. There is now an extensive monitoring program at the NTS to assess radiological conditions resulting from past tests and from continued testing of nuclear-weapons devices. In populated areas near NTS, there is also a monitoring effort that relies on assistance from local communities. Other efforts include reconstruction of radiation doses received by offsite residents during the 1950s and 1960s, determination of the current inventory and distribution of radionuclides in surface soil, and studies of the movement of radionuclides in the desert ecosystem

  16. Investigation of the dynamics of radiation pollution at the former Semipalatinsk nuclear test site

    International Nuclear Information System (INIS)

    Belyashov, L.; Yushkov, A.; Grinshtein, Yu.; Makarenko, N.

    1996-01-01

    Main Tasks: - To perform aerial gamma-spectrometric shooting of the whole territory of the Semipalatinsk test site in a scale 1:200,000 with registration of the total spectrum; - The same in a scale 1:10,000 for the Balapan region; - To construct the physical-mathematical forecasting models of the dynamics of radionuclide contamination at the STS area. Scientific and Technical Means, Methods, Approaches - Aerial gamma-spectroscopy on a base of the crystals of Iodine Sodium, activated by Thallium, volume 25 I, with registration of the total spectrum; - A set of the software and computational means along with the data bases; - The aerial gamma-spectrometric standard testing site 'irtysh' - for Cesium-137 and the testing sites 'Kora' and 'Aidarly' - for natural radio-nuclides; - Software and computational means for development of physical-mathematical models; - Expedition equipment for ground testing in the points of the most prominent radiation anomalies. Expected Results - The second temporal point, with an interval of five years, on a state of radiation fields at the STS in two scales. Forecasting models for space-time evolution of radiation fields at the STS. - The results of comparison between the aerial and ground measurements

  17. The assessment of radiation exposures in native American communities from nuclear weapons testing in Nevada

    International Nuclear Information System (INIS)

    Frohmberg, E.; Goble, R.; Sanchez, V.; Quigley, D.

    2000-01-01

    Native Americans residing in a broad region downwind from the Nevada Test Site during the 1950s and 1960s received significant radiation exposures from nuclear weapons testing. Because of differences in diet, activities, and housing, their radiation exposures are only very imperfectly represented in the Department of Energy dose reconstructions. There are important missing pathways, including exposures to radioactive iodine from eating small game. The dose reconstruction model assumptions about cattle feeding practices across a year are unlikely to apply to the native communities as are other model assumptions about diet. Thus exposures from drinking milk and eating vegetables have not yet been properly estimated for these communities. Through consultations with members of the affected communities, these deficiencies could be corrected and the dose reconstruction extended to Native Americans. An illustration of the feasibility of extending the dose reconstruction is provided by a sample calculation to estimate radiation exposures to the thyroid from eating radio-iodine-contaminated rabbit thyroids after the Dedan test. The illustration is continued with a discussion of how the calculation results may be used to make estimates for other tests and other locations

  18. Assessment of the Radiation Enclosure Models in SPACE and RELAP5 with GOTA Test 27

    Energy Technology Data Exchange (ETDEWEB)

    Lee, T. B.; Lee, G. W.; Choi, T. S. [KEPCO, Daejeon (Korea, Republic of)

    2016-05-15

    SPACE (Safety and Performance Analysis Code) for nuclear power plant has been developed to calculate the transient thermal-hydraulic response of PWRs that can contain multiple types of fluids. Without explaining 3-D effects such as the change of fuel rod/guide tube thermal behavior as a result of the radiation heat transfer, the 1-D code could predict an unrealistically high peak clad temperature. A useful function to simulate the wall-to-wall radiation heat transfer is implemented in the SPACE and RELAP5 codes. This paper discusses the assessment results of the radiation enclosure model of SPACE and RELAP5. The capability of handling wall-to-wall radiation problem of the SPACE and the RELAP5 codes has been evaluated using the experimental data from the GOTA test facility. At the top of the bundle, the maximum errors of SPACE and RELAP5 are less than 1.6% and 2.3%, respectively. As noted, there is a small discrepancy between the calculated results and experimental data except for the predictions near the top of the test section. The SPACE code is based on the version 2.16 distributed by KHNP. In order to perform the simulation of the GOTA test 27, it was necessary to modify the SPACE code. There was the subroutine for an input process corresponding to the radiation model, the inp{sub c}heck function of the RadEncData Class, contained in a vulnerable algorithm to figure out the reciprocity rule of the view factor.

  19. Use of micronucleus test in the assessment of radiation effects in aquatic environments

    International Nuclear Information System (INIS)

    Araujo, Edvaldo F. de; Silva, Luanna R.S.; Lima, Pedro A. de S.; Amancio, Francisco F.; Melo, Ana Maria M. de A.; Silva, Edvane B. da; Silva, Ronaldo C. da

    2011-01-01

    The study of the effects of radioactive substances on the environment is accomplished by radioecology. This science has played an important role in combating all forms of pollution. The uncontrolled use of physical and chemical agents has been a concern for environmental regulatory agencies, due to the serious damage to ecosystems. Aquatic organisms are exposed to a variety of pollutants harmful to aquatic systems. The mollusks Biomphalaria glabrata has been featured as a bioindicator to possess characteristics such as short reproductive cycle ease of maintenance in the laboratory and low maintenance cost. The micronucleus assay has been shown to be a great test to identify mutagenic effects caused by physical and chemical agents. In this study the frequency of micronuclei in haemocytes of Biomphalaria glabrata exposed to high doses of 60 Co gamma radiation contributing to a further standardization of this test as an indicator of the presence of radioactive contamination in aquatic environments. The young adult snails of Biomphalaria glabrata were divided into groups and subjected to a dose of 0 (control), 40 and 60 Gy of gamma radiation. The results showed that snails irradiated with 40 Gy showed a smaller number of haemocytes, whereas those exposed to 60 Gy had a greater quantity of these cells compared to control group. It can be concluded that the morphological analysis and the frequency of micronuclei in haemocytes of Biomphalaria glabrata exposed to 60 Co gamma radiation may be used in studies of the action of high doses of radiation in aquatic environments (author)

  20. Radiation tests at cryogenic temperature on selected organic materials for LHC

    International Nuclear Information System (INIS)

    Humer, K.; Weber, H.W.; Szeless, B.; Tavlet, M.

    1997-01-01

    Future multi-TeV particle accelerators like the CERN Large Hadron Collider (LHC) will use superconducting magnets in which organic materials will be exposed to high radiation levels at temperatures as low as 2 K. A representative selection of organic materials comprising insulating films, cable insulations, epoxy resins and composites were exposed to neutron and gamma radiation of a nuclear reactor. Depending on the type of materials, the integrated radiation doses varied between 180 kGy and 155 MGy. During irradiation, the samples were kept close to the boiling temperature of liquid nitrogen, i.e. at 80 K, and thereafter stored in liquid nitrogen and transferred at the same temperature into the testing device for measurement of tensile and flexural strength. Tests were carried out on the same materials at similar dose rates at room temperature, and the results are compared with the ones obtained at cryogenic temperature. They show that within the selected dose range, a number of organic materials are suitable for use in radiation fields of the LHC at cryogenic temperature

  1. Results of radiation tests at cryogenic temperature on some selected organic materials for the LHC

    International Nuclear Information System (INIS)

    Schoenbacher, H.; Szeless, B.; Tavlet, M.; Humer, K.; Weber, H.W.

    1996-01-01

    Future multi-TeV particle accelerators like the CERN Large Hadron Collider (LHC) will use superconducting magnets where organic materials will be exposed to high radiation levels at temperatures as low as 2 K. A representative selection of organic materials comprising insulating films, cable insulations, and epoxy-type impregnated resins were exposed to neutron and gamma radiation of a nuclear reactor. Depending on the type of materials, the integrated radiation doses varied between 180 kGy and 155 MGy. During irradiation, the samples were kept close to the boiling temperature of liquid nitrogen i.e. ∼ 80 K and thereafter stored in liquid nitrogen and transferred at the same temperature into the testing device for measurement of tensile and flexural strength. Tests were carried out on the same materials at similar dose rates at room temperature, and the results were compared with those obtained at cryogenic temperature. They show that, within the selected dose range, a number of organic materials are suitable for use in the radiation field of the LHC at cryogenic temperature. (orig.)

  2. Testing and analysis of tube voltage and tube current in the radiation generator for mammography

    International Nuclear Information System (INIS)

    Jung, Hong Ryang; Hong, Dong Hee; Han, Beom Hui

    2014-01-01

    Breast shooting performance management and quality control of the generator is applied to the amount of current IEC(International Electrotechnical Commission) 60601-2-45 tube voltage and tube current are based on standards that were proposed in the analysis of the test results were as follows. Tube voltage according to the value of the standard deviation by year of manufacture from 2001 to 2010 as a 42-3.15 showed the most significant, according to the year of manufacture by tube amperage value of the standard deviation to 6.38 in the pre-2000 showed the most significant , manufactured after 2011 the standard deviation of the devices, the PAE(Percent Average Error) was relatively low. This latest generation device was manufactured in the breast of the tube voltage and tube diagnosed shooting the correct amount of current to maintain the performance that can be seen. The results of this study as the basis for radiography diagnosed breast caused by using the device's performance and maintain quality control, so the current Food and Drug Administration 'about the safety of diagnostic radiation generator rule' specified in the test cycle during three years of self-inspection radiation on a radiation generating device ensure safety and performance of the device using a coherent X-ray(constancy) by two ultimately able to keep the radiation dose to the public to reduce the expected effect is expected

  3. Risk Perception of Radiation Exposure of Villagers Living Near the Semipalatinsk Nuclear Test Site

    Science.gov (United States)

    Purvis-Roberts, K. L.

    2006-12-01

    Connecting scientific data to societal needs is particularly important with the complex environmental issues that face us in the near future, such as global warming and natural hazards. Once the scientific data is collected and analyzed, dissemination of the results needs to be communicated to the public in a way that can be easily understood without glossing over the complexity of the issue. An interesting case study derives from the primary nuclear test site for the former Soviet Union, located near the city of Semipalatinsk, Kazakhstan. Villagers living directly adjacent to the Semipalatinsk Nuclear Test Site (SNTS) were exposed continuously to radioactive clouds from atmospheric, above ground and underground nuclear tests. The people living in the region are still exposed to low levels of radiation through the environmental contamination of their food and water and have experienced a higher incidence of cancers and birth defects than people living in other regions of the country. A database of historical environmental data was collected throughout the nuclear testing period by the Soviet government, tracking radiation concentrations through food, water, and soil samples around the SNTS, but this environmental data was never shared with the villagers. In fact, only after the Soviet Union fell apart in 1989 did the people discover that they had been exposed to radiation during the past 40 years. Through preliminary interviews with villagers, physicians, and scientists who live near the SNTS, it was discovered that the three groups viewed the risk of radiation exposure very differently. By developing a risk perception survey to understand how the different groups perceived radiation risk, and then comparing the scientific data to the survey results, a better way to communicate the risk could be developed. The risk perception survey was given to over 800 people in East Kazakhstan Oblast, including villagers living near the SNTS, scientists who study the

  4. Irradiation tests of a small-sized motor with radiation resistance

    International Nuclear Information System (INIS)

    Nakamichi, M.; Ishitsuka, E.; Shimakawa, S.; Kan, S.

    2007-01-01

    In the Test Blanket Module (TBM) of the International Thermonuclear Experimental Reactor (ITER), tritium production and release behavior will be studied using neutrons from fusion reactions, as the blanket development for a demonstration (DEMO) reactor. For development of the TBM, in-pile functional tests are planned, including an integrated irradiation experiment of a fusion blanket mock-up for pulsed operation simulating the ITER operation mode, using the Japan Materials Testing Reactor (JMTR) of Japan Atomic Energy Agency (JAEA).Due to be installed in an irradiation rig, a small-sized motor has to be developed for rotating a neutron absorber with a window to realize the simulated pulse operation. Since degradation of materials of the motor may be caused by radiation damage due to neutron and gamma-ray irradiation, it is important to examine the soundness of the motor materials under the neutron and gamma irradiation.In the present study, a small-sized motor with increased radiation resistance was developed as follows. A design of a commercial alternate current (AC) servomotor was adopted in the base structure, and some components of the motor were replaced by those made of radiation-proof materials, through elimination of organic materials. Polyester-coated wire for field coil and epoxy for fixed resin were replaced by polyimide-coated wire and polysiloxane filled with MgO and Al 2 O 3 , respectively. Furthermore, inorganic lubricant (Mo-based coating of 4 micro meter in thickness) was treated on the surface of a gear, instead of organic (polyphenylether) oil.Radiation-induced degradation of the components of the developed small-sized motor was examined using JMTR and the Japan Research Reactor No.4 (JRR-4) of JAEA. The motor was operating normally up to a gamma-ray dose of 7 x 10 8 Gy, a fast neutron (E>1 MeV) fluence of 2 x 10 21 m -2 and a thermal neutron (E 22 m -2 . The irradiated gamma-ray dose for this motor is about 700 times as high as the operation

  5. Performance test of SKIROC II ASIC chip for the radiation detection

    Energy Technology Data Exchange (ETDEWEB)

    Jun, W. J.; Namgoong, H.; Kim, B. K.; Song, H. S.; Kim, H. S.; Lee, S. H.; Choi, H. J.; Ghergherehchi, M.; Chai, J. S. [Sungkyunkwan University, Suwon (Korea, Republic of)

    2017-04-15

    There is a PCB board called FEV8 board which can readout analog signal from any energy source, and amplify it for signal processing. For precise detection, the board had been designed to operate in wide range of energy condition, with high-resolutive detection performance. This function has the possibility of the utilization for the radiation detection. The channels of the prototype board must be evaluated to make sure that the board is perfect or not. This research had made an progress for the radiation detection as well as the electronics of the intricate combination of the measurement instrumentations. The number of the noisy channels had been measured for threshold scan, and every channels in the board had been evaluated. By improving the experimental conditions such as test script in Linux system or well designed ground condition of the test bench, much more clean data will be able to be acquisited.

  6. Silicon Photo-Multiplier Radiation Hardness Tests with a White Neutron Beam

    International Nuclear Information System (INIS)

    Montanari, A.; Tosi, N.; Pietropaolo, A.; Andreotti, M.; Baldini, W.; Calabrese, R.; Cibinetto, G.; Luppi, E.; Cotta Ramusino, A.; Malaguti, R.; Santoro, V.; Tellarini, G.; Tomassetti, L.; De Donato, C.; Reali, E.

    2013-06-01

    We report radiation hardness tests performed, with a white neutron beam, at the Geel Electron Linear Accelerator in Belgium on silicon Photo-Multipliers. These are semiconductor photon detectors made of a square matrix of Geiger-Mode Avalanche photo-diodes on a silicon substrate. Several samples from different manufacturers have been irradiated integrating up to about 6.2 x 10 9 1-MeV-equivalent neutrons per cm 2 . (authors)

  7. Effect of Miradol (Sulpiride) on radiation sickness studied by a double-blind test

    International Nuclear Information System (INIS)

    Murakami, Yuko; Morita, Shinroku

    1981-01-01

    Effect of Miradol on radiation sickness was investigated by a double-blind test. The rate of ''effective'' was 66.7% of the patients given Miradol and 20.1% of those given placebo (p < 0.01). The drug was especially effective on the patients chiefly complaining of nausea and vomiting. Placebo was also effective in some of the cases with appetite loss etc. (Ueda, J.)

  8. Commercial Off-The-Shelf (COTS) Graphics Processing Board (GPB) Radiation Test Evaluation Report

    Science.gov (United States)

    Salazar, George A.; Steele, Glen F.

    2013-01-01

    Large round trip communications latency for deep space missions will require more onboard computational capabilities to enable the space vehicle to undertake many tasks that have traditionally been ground-based, mission control responsibilities. As a result, visual display graphics will be required to provide simpler vehicle situational awareness through graphical representations, as well as provide capabilities never before done in a space mission, such as augmented reality for in-flight maintenance or Telepresence activities. These capabilities will require graphics processors and associated support electronic components for high computational graphics processing. In an effort to understand the performance of commercial graphics card electronics operating in the expected radiation environment, a preliminary test was performed on five commercial offthe- shelf (COTS) graphics cards. This paper discusses the preliminary evaluation test results of five COTS graphics processing cards tested to the International Space Station (ISS) low earth orbit radiation environment. Three of the five graphics cards were tested to a total dose of 6000 rads (Si). The test articles, test configuration, preliminary results, and recommendations are discussed.

  9. Computer aided periodical and regulated service tests on radiation measuring systems

    International Nuclear Information System (INIS)

    Sandner, W.; Lin, R.; Rothhaupt, W.

    1994-01-01

    Measuring systems for radioactive radiation, which must be registered by official order, have to be tested periodically according to laid down rules (WKP). A strategy for a test-device was drawn up for a flexible adaption of the procedure to individual requests, but also for a standardization of the logical interface to the measuring system. Especially the interaction of testing and normal measuring procedures is clearly defined and transparent; the original functional parts of the measuring run are used during the test as far as possible. Adapation to individual requirements is controlled by ASCII-Files, so that the program code remains unchanged. The functional possibilities are extensive also for the inspections by customers and authorities. Due to the nearly automatical run of the procedure, including printout of the results, the tests are always comparable. The standard was checked by some actual projects, basede on SYSTEM 7000 (Thermo Instrument Systems GmbH) and PC runing under DOS. (orig.) [de

  10. Radiation doses to local populations near nuclear weapons test sites worldwide.

    Science.gov (United States)

    Simon, Steven L; Bouville, André

    2002-05-01

    Nuclear weapons testing was conducted in the atmosphere at numerous sites worldwide between 1946 and 1980, which resulted in exposures to local populations as a consequence of fallout of radioactive debris. The nuclear tests were conducted by five nations (United States, Soviet Union, United Kingdom, France, and China) primarily at 16 sites. The 16 testing sites, located in nine different countries on five continents (plus Oceania) contributed nearly all of the radioactive materials released to the environment by atmospheric testing; only small amounts were released at a fewother minor testing sites. The 16 sites discussed here are Nevada Test Site, USA (North American continent), Bikini and Enewetak, Marshall Islands (Oceania); Johnston Island, USA (Oceania), Christmas and Malden Island, Kiribati (Oceania); Emu Field, Maralinga, and Monte Bello Islands, Australia (Australian continent); Mururoa and Fangataufa, French Polynesia (Oceania), Reggane, Algeria (Africa), Novaya Zemlya and Kapustin Yar, Russia (Europe), Semipalatinsk, Kazakhstan (Asia), and Lop Nor, China (Asia). There were large differences in the numbers of tests conducted at each location and in the total explosive yields. Those factors, as well as differences in population density, lifestyle, environment, and climate at each site, led to large differences in the doses received by local populations. In general, the tests conducted earliest led to the highest individual and population exposures, although the amount of information available for a few of these sites is insufficient to provide any detailed evaluation of radiation exposures. The most comprehensive information for any site is for the Nevada Test Site. The disparities in available information add difficulty to determining the radiation exposures of local populations at each site. It is the goal of this paper to summarize the available information on external and internal doses received by the public living in the regions near each of the

  11. Test and Evaluation of Fiber Optic Sensors for High-Radiation Space Nuclear Power Applications

    International Nuclear Information System (INIS)

    Klemer, Daniel; Fielder, Robert S.; Stinson-Bagby, Kelly L.

    2004-01-01

    Fiber optic sensors can be used to measure a number of parameters, including temperature, strain, pressure and flow, for instrumentation and control of space nuclear power systems. In the past, this technology has often been rejected for use in such a high-radiation environment based on early experiments that revealed a number of degradation phenomena, including radiation-induced fiber attenuation, or 'graying', and Fiber Bragg Grating (FBG) fading and wavelength shift. However, this paper reports the results of recent experimental testing that demonstrates readability of fiber optic sensors to extremely high levels of neutron and gamma radiation. Both distributed Fiber Bragg Grating (FBG) sensors and single-point Extrinsic Fabry Perot Interferometer (EFPI) sensors were continuously monitored over a 2-month period, during which they were exposed to combined neutron and gamma radiation in both in-core and ex-core positions within a nuclear reactor. Total exposure reached approximately 2 x 10 19 cm -2 fast neutron (E > 1 MeV) fluence and 8.7 x 10 8 Gy gamma for in-core sensors. FBG sensors were interrogated using a standard Luna Innovations FBG measurement system, which is based on optical frequency-domain reflectometer (OFDR) technology. Approximately 74% of the 19 FBG sensors located at the core centerline in the in-core position exhibited sufficient signal-to-noise ratio (SNR) to remain readable even after receiving the maximum dose. EFPI sensors were spectrally interrogated using a broadband probe source operating in the 830 nm wavelength region. While these single-point sensors failed early in the test, important additional fiber spectral transmission data was collected, which indicates that interrogation of EFPI sensors in alternate wavelength regions may allow significant improvement in sensor longevity for operation in high-radiation environments. This work was funded through a Small Business Innovative Research (SBIR) contract with the Nasa Glenn Research

  12. Fast microwave detection system for coherent synchrotron radiation study at KEK: Accelerator test facility

    International Nuclear Information System (INIS)

    Aryshev, A.; Araki, S.; Karataev, P.; Naito, T.; Terunuma, N.; Urakawa, J.

    2007-01-01

    A fast room temperature microwave detection system based on the Schottky Barrier-diode detector was created at the KEK ATF (Accelerator Test Facility). It was tested using Coherent Synchrotron Radiation (CSR) generated by the 1.28 GeV electron beam in the damping ring. The speed performance of the detection system was checked by observing the CSR from a multi-bunch (2.8 ns bunch separation time) beam. The theoretical estimations of CSR power yield from an edge of bending magnet as well as new injection tuning method are presented. A very high sensitivity of CSR power yield to the longitudinal electron distribution in a bunch is discussed

  13. A note on Poisson goodness-of-fit tests for ionizing radiation induced chromosomal aberration samples.

    Science.gov (United States)

    Higueras, Manuel; González, J E; Di Giorgio, Marina; Barquinero, J F

    2018-05-18

    To present Poisson exact goodness-of-fit tests as alternatives and complements to the asymptotic u-test, which is the most widely used in cytogenetic biodosimetry, to decide whether a sample of chromosomal aberrations in blood cells comes from an homogeneous or inhomogeneous exposure. Three Poisson exact goodness-of-fit test from the literature are introduced and implemented in the R environment. A Shiny R Studio application, named GOF Poisson, has been updated for the purpose of giving support to this work. The three exact tests and the u-test are applied in chromosomal aberration data from clinical and accidental radiation exposure patients. It is observed how the u-test is not an appropriate approximation in small samples with small yield of chromosomal aberrations. Tools are provided to compute the three exact tests, which is not as trivial as the implementation of the u-test. Poisson exact goodness-of-fit tests should be considered jointly to the u-test for detecting inhomogeneous exposures in the cytogenetic biodosimetry practice.

  14. Safety Evaluation Test on Human for Radiation Pre vulcanised Natural Rubber Latex (RVNRL)

    International Nuclear Information System (INIS)

    Pairu Ibrahim; Wan Manshol Wan Zain; Chai, Chee Keong; Sofian Ibrahim; Saadiah Sulaiman; Sharifah Ismail

    2010-01-01

    This paper discussed about clinical test conducted to determine safety evaluations on human for latex examination gloves and latex films made from Radiation Vulcanized Natural Rubber Latex (RVNRL). Two types of test were being adopted which are i) Modified Draize-95 test and ii) Patch Test on Sensitized Individuals. Modified Draize-95 test was conducted on 200 non-sensitized human subjects and Patch Test on Sensitized Individuals was conducted on 25 individuals who are allergic to the defined major chemical sensitizer presents in natural rubber product. It was found that Modified Draize-95 test has prove that there is no clinical evidence on the presence of residual chemical additives at the level that may induce Type IV allergy in the un sensitized general user population in the RVNRL gloves. Meanwhile Patch Test on Sensitized Individuals has proved that the patch test conducted using the test article on 25 individuals who are allergic to the defined major chemical sensitizers present in natural rubber products, thiuram, carbamates or thiazoles produced a negative response, meeting the pre requirement for the claim of reduced reaction-inducing potential. (author)

  15. 养殖浅色黄姑鱼体表溃烂症病原菌的分离与鉴定%Isolation and identification of a bacterial pathogen from Chu's croaker Nibea coibor

    Institute of Scientific and Technical Information of China (English)

    谢楚萍; 黄思韵; 郑仰思; 李升康; 周立镇; 温小波

    2013-01-01

    浅色黄姑鱼的高密度养殖一直受到病害的困扰,导致成鱼养殖成活率低,直接影响了浅色黄姑鱼养殖业的发展.以汕头南澳岛患皮肤溃烂症的养殖浅色黄姑鱼为材料,从其溃烂头部组织中分离得到优势菌KLg,人工感染实验证实菌株KLg为浅色黄姑鱼的致病菌.药敏试验表明菌株KLg对头孢哌酮、红霉素、头孢曲松、先锋霉素V、复达欣、头孢呋辛和氧哌嗪青霉素等7种抗生素敏感,革兰氏染色、生理生化测定等手段初步确定菌株KLg为哈维氏弧菌(Vibrio harveyi),这一结果通过16S rDNA基因序列及进化树分析得到进一步确认.哈维氏弧菌是海水养殖鱼类的常见致病菌,但在浅色黄姑鱼养殖中尚属首次报道.实验结果可为我国沿海地区浅色黄姑鱼养殖中弧菌病害的防治提供重要参考.%The usual occurrence of the diseases,which results in high mortality of adult Chu's croaker (Nibea coibor),have a negative effect on the development of high density croaker mariculture.In the present study,the pathogenic bacteria were isolated from the head of the diseased croaker of Nanao isoland,Shantou,China.A dominant green isolate (named KLg) was retrieved from the croaker.KLg was proved to be the pathogen of the diseased croaker by artificial infection and the drug sensitivity test of KLg showed that the pathogen was sensitive to 7 antibiotics such as cefoerrazone,erythromycin,ceftriaxone,cefazolin,ceftazidine,cefuroxime and piperacillin.The strain was further confirmed to be affiliated with Vibrio harveyi after gram stain,biochemical test and phylogenetic analysis and reconfirmed by 16S rDNA gene sequence and phylogenetic analysis.To our knowledge,this is the first report that V.harveyi was found to be the pathogen of cultured Chu's croaker in southern China.The results here would lay a basis on further disease prevention and remediation of Chu's croaker N.coibor in future.

  16. Laboratory methods used for testing the effect of radiation sterilization and preservation procedures on bone allografts

    International Nuclear Information System (INIS)

    Dziedzic-Goclawska, A.

    1999-01-01

    ionizing radiation (in the range of 20-35 kGy) used for sterilization of bone allografts change their mechanical properties. Some parameters such as bending and compression forces as well as torsion moment has been measured and/or the three-point bending test was applied using an Instron Universal Testing Machine to evaluate 'strength', 'stiffness, 'toughness' and 'ductility' of bone samples preserved by different methods and radiation-sterilized at various conditions

  17. Offsite environmental monitoring report. Radiation monitoring around United States nuclear test areas, calendar year 1980

    International Nuclear Information System (INIS)

    Smith, D.D.; Grossman, R.F.; Corkern, W.D.; Thome, D.J.; Patzer, R.G.; Hopper, J.L.

    1981-06-01

    The US Environmental Protection Agency's (EPA) Environmental Monitoring Systems Laboratory in Las Vegas (EMSL-LV) continued its Offsite Radiological Safety Program for the Nevada Test Site (NTS) and other sites of past underground nuclear tests. For each test, the Laboratory provided airborne meteorological measurements, ground and airborne radiation monitoring teams, and special briefings to the Test Controller's Advisory Panel. Test-related radioactivity from the NTS was detected offsite following the Riola Test conducted on September 25, 1980. This consisted of xenon-133 (3.4 x 10 -11 μCi/m1) and xenon-135 (3.6 x 10 -10 μCi/m1) in a compressed air sample collected at Lathrop Wells, Nevada. The estimated dose equivalent to the whole body of a hypothetical receptor at Lathrop Wells from exposure to the radioxenon was 0.011 mrem, which is 0.006 percent of the radiation protection guide for a suitable sample of the general population. Whole-body counts of individuals residing in the environs of the NTS showed no manmade radionuclides attributable to the testing program. The only radioactivity from non-NTS sites of past underground nuclear tests was due to tritium in water samples collected from the Project Dribble Site near Hattiesburg, Mississippi, and the Project Long Shot Site on Amchitka Island, Alaska. The maximum concentrations measured at these locations were 1 and 0.1 percent of the Concentration Guide for drinking water, respectively. A small amount of airborne radioactivity originating from nuclear tests carried out by the People's Republic of China was detected during 1980 at some stations scattered throughout the Air Surveillance Network. The Laboratory's Animal Investigation Program sampled tissues from wildlife and domestic animals on and around the NTS. Data from analysis of these tissues are published separately in an annual report

  18. Development of quality assurance programme for prescribed ionizing radiation source testing. Recommendations

    International Nuclear Information System (INIS)

    1999-01-01

    The document gives guidance to those applying for licence to perform ionizing radiation source acceptance tests and long-term stability tests and provides information which should be known when introducing quality assurance systems in compliance with legislative requirements. It is envisaged that this document ('Recommendations') will form a basis for final Safety Guides to be issued by the State Office for Nuclear Safety, the Czech nuclear regulatory authority. The setup of the publication is as follows. Part I gives a glossary of basic terms in quality systems. Part 2 explains quality system principles, paying special attention to radiation safety issues, and describes the structure and scope of quality system documentation. Part 3 explains the individual elements of the quality system and gives practical examples. Part 4 deals with the quality assurance programme; using instructions and practical examples, this part shows how the quality system elements should be applied to long-time stability testing and acceptance testing. A model structure of 2nd degree documentation (guidelines) and a model testing protocol are given in annexes. (P.A.)

  19. The HAW Project. Test disposal of highly radioactive radiation sources in the Asse salt mine

    International Nuclear Information System (INIS)

    Rothfuchs, T.; Mueller-Lyda, I.; Raynal, M.; Major, J.C.

    1993-01-01

    In order to prove the safe disposal of high-level radioactive waste (HAW) in salt a five years test disposal of thirty highly radioactive canisters is planned in the Asse salt mine in the Federal Republic of Germany. The thirty canisters containing the radionuclides Caesium 137 and Strontium 90 in quantities sufficient to cover the bandwith of heat generation and gamma radiation of real HAW will be emplaced in six boreholes located in two galleries at the 800-m-level. Two electrical heater tests were already started in November 1988 and are continuously surveyed in respect of the thermomechanical and geochemical response of the rock mass. Also the handling system necessary for the emplacement of the radioactive canisters was developed and successfully tested. A laboratory investigation programme on radiation effects in salt is being performed in advance to the radioactive canister emplacement. This programme includes the investigation of thermally and radiolytically induced water and gas release from the rock salt and the radiolytical decomposition of salt minerals. For gamma dose and dose rate measurements in the test field measuring systems consisting of ionization chambers as well as solid state dosemeters were developed and tested. 70 refs

  20. Monte Carlo simulation of the sequential probability ratio test for radiation monitoring

    International Nuclear Information System (INIS)

    Coop, K.L.

    1984-01-01

    A computer program simulates the Sequential Probability Ratio Test (SPRT) using Monte Carlo techniques. The program, SEQTEST, performs random-number sampling of either a Poisson or normal distribution to simulate radiation monitoring data. The results are in terms of the detection probabilities and the average time required for a trial. The computed SPRT results can be compared with tabulated single interval test (SIT) values to determine the better statistical test for particular monitoring applications. Use of the SPRT in a hand-and-foot alpha monitor shows that the SPRT provides better detection probabilities while generally requiring less counting time. Calculations are also performed for a monitor where the SPRT is not permitted to the take longer than the single interval test. Although the performance of the SPRT is degraded by this restriction, the detection probabilities are still similar to the SIT values, and average counting times are always less than 75% of the SIT time. Some optimal conditions for use of the SPRT are described. The SPRT should be the test of choice in many radiation monitoring situations. 6 references, 8 figures, 1 table

  1. Test reference year generation from meteorological and simulated solar radiation data

    Energy Technology Data Exchange (ETDEWEB)

    Miguel, A. de; Bilbao, J. [University of Valladolid (Spain). Dept. of Applied Physics

    2005-06-01

    In this paper, a new method for generating test reference year (TRY) from the measured meteorological variables is proposed. Hourly recorded data of air temperature, relative humidity and wind velocity for two stations, Valladolid and Madrid (Spain) were selected to develop the method and a TRY was obtained. Monthly average solar radiation values were calculated taking into account the temperature and solar radiation correlations. Four different methodologies were used to evaluate hourly global solar radiation from hourly weather data of temperature and, as a consequence, four different TRYs with common data sets of temperature, relative humidity and wind velocity were generated for Valladolid and Madrid (Spain) stations. In order to evaluate the four different methodologies, TRYs data were compared with long-term measured data series using statistical estimators such as average, standard deviation, root mean square error (rmse) and mean bias error (mbe). Festa and Ratto and the TAG model, from Aguiar and Collares-Pereira, respectively, turned out to be the best methods for generating hourly solar irradiation data. The best performance was shown by the TRY0 year which was based on the solar radiation models mentioned above. The results show that the best reference year for each site varies with the season and the characteristics of the station. (author)

  2. Influence of ionizing radiation on the catalytic properties of oxide catalysts tested by hydrogen peroxide decomposition

    International Nuclear Information System (INIS)

    Mucka, V.

    1987-01-01

    Results of a study of some physical and catalytic properties of different oxide catalysts as affected by ionizing radiation (γ, n, e - ) and tested by the decomposition of hydrogen peroxide in aqueous solution are presented in this paper. The oxidation state of the active component present on the catalyst surface was found to be one of the most sensitive properties to the ionizing radiation. Changes of this state induced by γ-irradiation were found to be positive in most cases; electron pre-irradiation of the oxides leads, as a rule, to negative effects and the effects of neutron irradiation may be positive or negative. On the other hand, changes in the catalytic activity of the oxides after γ-or electron-irradiation seem to be mostly negative and positive, respectively; the effects of fast neutrons seem to vary here. Neither quantitative or qualitative correlation was found between the radiation-induced changes in these two quantities. The results give evidence that ionizing radiation principally affects the surface concentration of the catalytic sites. Both the character and magnitude of the changes in surface oxidation abilities and in catalytic activities of the oxide catalysts seem to be dependent upon the actual state of the catalyst surface. (author)

  3. Ionizing radiation test results for an automotive microcontroller on board the Schiaparelli Mars lander

    Science.gov (United States)

    Tapani Nikkanen, Timo; Hieta, Maria; Schmidt, Walter; Genzer, Maria; Haukka, Harri; Harri, Ari-Matti

    2016-04-01

    The Finnish Meteorological Institute (FMI) has delivered a pressure and a humidity instrument for the ESA ExoMars 2016 Schiaparelli lander mission. Schiaparelli is scheduled to launch towards Mars with the Trace Gas Orbiter on 14th of March 2016. The DREAMS-P (pressure) and DREAMS-H (Humidity) instruments are operated utilizing a novel FMI instrument controller design based on a commercial automotive microcontroller (MCU). A custom qualification program was implemented to qualify the MCU for the relevant launch, cruise and surface operations environment of a Mars lander. Resilience to ionizing radiation is one of the most critical requirements for a digital component operated in space or at planetary bodies. Thus, the expected Total Ionizing Dose accumulated by the MCU was determined and a sample of these components was exposed to a Co-60 gamma radiation source. Part of the samples was powered during the radiation exposure to include the effect of electrical biasing. All of the samples were verified to withstand the expected total ionizing dose with margin. The irradiated test samples were then radiated until failure to determine their ultimate TID.

  4. Radiation hardness tests of piezoelectric actuators with fast neutrons at liquid helium temperature

    Energy Technology Data Exchange (ETDEWEB)

    Fouaidy, M.; Martinet, G.; Hammoudi, N.; Chatelet, F.; Olivier, A.; Blivet, S.; Galet, F. [CNRS-IN2P3-IPN Orsay, Orsay (France)

    2007-07-01

    Piezoelectric actuators, which are integrated into the cold tuning system and used to compensate the small mechanical deformations of the cavity wall induced by Lorentz forces due to the high electromagnetic surface field, may be located in the radiation environment during particle accelerator operation. In order to provide for a reliable operation of the accelerator, the performance and life time of piezoelectric actuators ({approx}24.000 units for ILC) should not show any significant degradation for long periods (i.e. machine life duration: {approx}20 years), even when subjected to intense radiation (i.e. gamma rays and fast neutrons). An experimental program, aimed at investigating the effect of fast neutrons radiation on the characteristics of piezoelectric actuators at liquid helium temperature (i.e. T{approx}4.2 K), was proposed for the working package WPNo.8 devoted to tuners development in the frame of CARE project. A neutrons irradiation facility, already installed at the CERI cyclotron located at Orleans (France), was upgraded and adapted for actuators irradiations tests purpose. A deuterons beam (maximum energy and beam current: 25 MeV and 35{mu}A) collides with a thin (thickness: 3 mm) beryllium target producing a high neutrons flux with low gamma dose ({approx}20%): a neutrons fluence of more than 10{sup 14} n/cm{sup 2} is achieved in {approx}20 hours of exposure. A dedicated cryostat was developed at IPN Orsay and used previously for radiation hardness test of calibrated cryogenic thermometers and pressure transducers used in LHC superconducting magnets. This cryostat could be operated either with liquid helium or liquid argon. This irradiation facility was upgraded for allowing fast turn-over of experiments and a dedicated experimental set-up was designed, fabricated, installed at CERI and successfully operated for radiation hardness tests of several piezoelectric actuators at T{approx}4.2 K. This new apparatus allows on-line automatic measurements

  5. Radiation hardness tests of piezoelectric actuators with fast neutrons at liquid helium temperature

    International Nuclear Information System (INIS)

    Fouaidy, M.; Martinet, G.; Hammoudi, N.; Chatelet, F.; Olivier, A.; Blivet, S.; Galet, F.

    2007-01-01

    Piezoelectric actuators, which are integrated into the cold tuning system and used to compensate the small mechanical deformations of the cavity wall induced by Lorentz forces due to the high electromagnetic surface field, may be located in the radiation environment during particle accelerator operation. In order to provide for a reliable operation of the accelerator, the performance and life time of piezoelectric actuators (∼24.000 units for ILC) should not show any significant degradation for long periods (i.e. machine life duration: ∼20 years), even when subjected to intense radiation (i.e. gamma rays and fast neutrons). An experimental program, aimed at investigating the effect of fast neutrons radiation on the characteristics of piezoelectric actuators at liquid helium temperature (i.e. T∼4.2 K), was proposed for the working package WPNo.8 devoted to tuners development in the frame of CARE project. A neutrons irradiation facility, already installed at the CERI cyclotron located at Orleans (France), was upgraded and adapted for actuators irradiations tests purpose. A deuterons beam (maximum energy and beam current: 25 MeV and 35μA) collides with a thin (thickness: 3 mm) beryllium target producing a high neutrons flux with low gamma dose (∼20%): a neutrons fluence of more than 10 14 n/cm 2 is achieved in ∼20 hours of exposure. A dedicated cryostat was developed at IPN Orsay and used previously for radiation hardness test of calibrated cryogenic thermometers and pressure transducers used in LHC superconducting magnets. This cryostat could be operated either with liquid helium or liquid argon. This irradiation facility was upgraded for allowing fast turn-over of experiments and a dedicated experimental set-up was designed, fabricated, installed at CERI and successfully operated for radiation hardness tests of several piezoelectric actuators at T∼4.2 K. This new apparatus allows on-line automatic measurements of actuators characteristics and the

  6. Test tools of physics radiography children as a support for safety radiation and safety patients

    International Nuclear Information System (INIS)

    Siti Masrochah; Yeti Kartikasari; Ardi Soesilo Wibowo

    2013-01-01

    Radiographic examination of the thorax children aged 1-3 years have a high sufficiently failure. This failure is caused by the movement and difficulty positioning the patient, resulting in the risk of repeat radiographs to patient safety particularly unnecessary radiation risks. It is therefore necessary to develop research on children design fixation devices. This research aims to create a design tool fixation on radiographs children to support radiation safety and patient safety. This research is a descriptive exploratory approach to tool design. The independent variables were the design tools, variable tool function test results, and radiographic variables controlled thorax. The procedure is done by designing data collection tools, further trials with 20 samples. Processing and analysis of data is done by calculating the performance assessment tool scores with range 1-3. The results showed that the design tool of fixation in the form of standard radiographic cassette equipped with chairs and some form of seat belt fixation. The procedure uses a tool fixation is routine radiographic follow thorax child in an upright position. Function test results aids fixation is to have an average score of 2.66, which means good. While the test results for each component, the majority of respondents stated that the reliability of the device is quite good with a score of 2.45 (60 %), convenience tool with a score of 2.60 (70 %), quality of the radiographs did not incontinence of the thorax radiograph with a score 2.55 (85 %), the child protection (security) with a score of 2.70 (70 %), good design aesthetic design with a score of 2.80 (80 %), addition of radiation from the others on the use of these tools do not need with a score of 2.80 (80 %), and there is no additional radiation due to repetitions with a score of 2.85 (90 %). (author)

  7. Design and Testing of an Active Heat Rejection Radiator with Digital Turn-Down Capability

    Science.gov (United States)

    Sunada, Eric; Birur, Gajanana C.; Ganapathi, Gani B.; Miller, Jennifer; Berisford, Daniel; Stephan, Ryan

    2010-01-01

    NASA's proposed lunar lander, Altair, will be exposed to vastly different external environment temperatures. The challenges to the active thermal control system (ATCS) are compounded by unfavorable transients in the internal waste heat dissipation profile: the lowest heat load occurs in the coldest environment while peak loads coincide with the warmest environment. The current baseline for this fluid is a 50/50 inhibited propylene glycol/water mixture with a freeze temperature around -35 C. While the overall size of the radiator's heat rejection area is dictated by the worst case hot scenario, a turn-down feature is necessary to tolerate the worst case cold scenario. A radiator with digital turn-down capability is being designed as a robust means to maintain cabin environment and equipment temperatures while minimizing mass and power consumption. It utilizes active valving to isolate and render ineffective any number of parallel flow tubes which span across the ATCS radiator. Several options were assessed in a trade-study to accommodate flow tube isolation and how to deal with the stagnant fluid that would otherwise remain in the tube. Bread-board environmental tests were conducted for options to drain the fluid from a turned-down leg as well an option to allow a leg to freeze/thaw. Each drain option involved a positive displacement gear pump with different methods of providing a pressure head to feed it. Test results showed that a start-up heater used to generate vapor at the tube inlet held the most promise for tube evacuation. Based on these test results and conclusions drawn from the trade-study, a full-scale radiator design is being worked for the Altair mission profile.

  8. Problems studied within the state research project New Methods of Nondestructive Materials Testing Using Ionizing Radiation

    International Nuclear Information System (INIS)

    Mysak, F.; Strba, J.

    1979-01-01

    A state research project is described divided into ten subprojects, viz.: New trends of ionizing radiation detection using television technology in nondestructive testing; the application of accelerators for thick-walled product testing; the atlas of butt welds of medium thicknesses; the application of radioanalytical methods in testing the wear of gearboxes and other components of instrument parts; multielemental analyses of combustion engine wear using radionuclides; the application of radioisotope methods in research into wear of antifriction bearings of trucks and railway cars; the application of radionuclides in assessing corrosion resistance of steels and corrosion protection systems; the application of radionuclide methods in improving the quality of high-grade steel production; the selection and testing of radionuclide instruments for building production control, intermediate and acceptance checks; and radioisotope methods for building machine and equipment control. (M.S.)

  9. Radiated EMC& EMI Management During Design Qualification and Test Phases on LEO Satellites Constellation

    Science.gov (United States)

    Blondeaux, H.; Terral, M.; Gutierrez-Galvan, R.; Baud, C.

    2016-05-01

    The aim of the proposed paper is to present the global radiated EMC/EMI approach applied by Thales Alenia Space in the frame of a telecommunication Low Earth Orbit (LEO) satellites constellation program. The paper will present this approach in term of analyses, of specific characterisation and of sub-system and satellite tests since first design reviews up-to satellite qualification tests on Prototype Flight Model (PFM) and to production tests on reduced FMs. The global aim is : 1 - to reduce risk and cost (units EMC delta qualification, EMC tests at satellite level for the 81 Space Vehicles (SV) through appropriated EMC analyses (in term of methodologies and contours) provided in the frame of design reviews.2 - to early anticipate potential critical case to reduce the impact in term of engineering/qualification/test extra cost and of schedule.3 - to secure/assure the payload and SV design/layout.4 - to define and optimize the EMC/EMI test campaigns to be performed on Prototype Flight Model (PFM) for complete qualification and on some FMs for industrial qualification/validation.The last part of the paper is dedicated to system Bite Error Rate (BER) functional test performed on PFM SV to demonstrate the final compatibility between the three on-board payloads and to the Internal EMC tests performed on PFM and some FMs to demonstrate the SV panel RF shielding efficiency before and after environmental tests and the Thales Alenia Space (TAS) and Orbital AKT (OATK) workmanships reproducibility.

  10. Fabrication of vitrified isotopic heat and radiation sources for testing in the Asse Mine

    International Nuclear Information System (INIS)

    Holton, L.K.; Burkholder, H.C.; McElroy, J.L.; Kahl, L.; Kroebel, R.; Rothfuchs, T.; Strippler, R.

    1989-02-01

    The Pacific Northwest Laboratory (PNL), under contract to the US Department of Energy, has produced 30 isotopic heat and radiation sources (canisters) for the Federal Republic of Germany (FRG) to be used as part of a repository testing program in the Asse Salt Mine. PNL was responsible for the fabrication, including filling, closing, decontaminating, and characterizing the canisters. The canisters were fabricated (filled) in three separate processing campaigns using the radioactive liquid-fed ceramic melter to produce a borosilicate glass. Radiochemical constituents ( 137 Cs and 90 Sr) were immobilized within the borosilicate glass matrix to yield a product with a predetermined decay heat and surface radiation exposure rate. Canister lid-welding was completed using an autogenous gas tungsten arc welding process. A helium leak test of lid weld tightness verified the leak rate to be no greater than 2.4 /times/ 10/sup /minus/8/ atm-cc/sec, which was less than the criterion of 10/sup /minus/7/ atm-cc/sec. The top, sides, and bottom of the canisters were decontaminated by electropolishing. All canisters were decontaminated to surface smear contamination levels of less than 33 Bq/100 cm 2 beta-gamma radiation. No significant alpha contamination was observed on canister surfaces. 11 figs., 2 tabs

  11. Evaluation of testing strategies for the radiation tolerant ATLAS n **+-in-n pixel sensor

    CERN Document Server

    Klaiber Lodewigs, Jonas M

    2003-01-01

    The development of particle tracker systems for high fluence environments in new high-energy physics experiments raises new challenges for the development, manufacturing and reliable testing of radiation tolerant components. The ATLAS pixel detector for use at the LHC, CERN, is designed to cover an active sensor area of 1.8 m**2 with 1.1 multiplied by 10 **8 read-out channels usable for a particle fluence up to 10 **1**5 cm**-**2 (1 MeV neutron equivalent) and an ionization dose up to 500 kGy of mainly charged hadron radiation. To cope with such a harsh environment the ATLAS Pixel Collaboration has developed a radiation hard n **+-in-n silicon pixel cell design with a standard cell size of 50 multiplied by 400 mum**2. Using this design on an oxygenated silicon substrate, sensor production has started in 2001. This contribution describes results gained during the development of testing procedures of the ATLAS pixel sensor and evaluates quality assurance procedures regarding their relevance for detector operati...

  12. Radiation Testing at Sandia National Laboratories: Sandia – JPL Collaboration for Europa Lander

    Energy Technology Data Exchange (ETDEWEB)

    Hattar, Khalid Mikhiel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Ion Beam Lab.; Olszewska-Wasiolek, Maryla Aleksandra [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Gamma Irradiation Facility

    2017-01-01

    Sandia National Laboratories (SNL) is assisting Jet Propulsion Laboratory in undertaking feasibility studies and performance assessments for the Planetary Protection aspect of the Europa Lander mission. The specific areas of interest for this project are described by task number. This white paper presents the evaluation results for Task 2, Radiation Testing, which was stated as follows: Survey SNL facilities and capabilities for simulating the Europan radiation environment and assess suitability for: A. Testing batteries, electronics, and other component and subsystems B. Exposing biological organisms to assess their survivability metrics. The radiation environment the Europa Lander will encounter on route and in orbit upon arrival at its destination consists primarily of charged particles, energetic protons and electrons with the energies up to 1 GeV. The charged particle environments can be simulated using the accelerators at the Ion Beam Laboratory. The Gamma Irradiation Facility and its annex, the Low Dose Rate Irradiation Facility, offer irradiations using Co-60 gamma sources (1.17 and 1.33 MeV), as well as Cs-137 gamma (0.661 MeV) AmBe neutron (0-10 MeV) sources.

  13. Thyroid nodule prevalence and radiation dose from fallout near the Semipalatinsk test site in Kazakhstan

    International Nuclear Information System (INIS)

    Land, C.E.; Luckyanov, N.K.; Simon, S.L.; Zhumadilov, Z.; Gusev, B.I.; Hartshorne, M.N.; Carr, Z.A.

    2003-01-01

    Thyroid nodule prevalence was use as a biomarker for radiation-related thyroid cancer risk associated with dose from internal and external radiation sources in fallout from the Semipalatinsk Test Site (STS) in Kazakhstan. Ultrasound scans were done on the thyroid glands of 1990 current residents of 7 villages near the STS, all members of a defined study cohort established in the 1960s, and all juveniles at some time during 1949-1962. Questionnaire-guided interviews focused on residential history and childhood consumption of milk and milk products. A refined dose reconstruction algorithm, developed jointly by experts from Russia and the US, was applied to the resulting data to calculate individual estimates of thyroid dose from external and internal sources of fallout-related radiation. Individual radiation dose estimates ranged from zero to 20 Gy for total dose (0-1.7 Gy and 0-20 Gy for dose from external and internal sources, respectively). The ratio of internal to external dose generally increased with increasing distance, reflecting a shift towards smaller particle sizes at greater distances and more effective transfer of small particles through the foodchain. Dose-response analysis was focused on variation of nodule prevalence by sex, age at screening, measured thyroid volume, and reconstructed thyroid dose from external (mainly gamma-ray) and internal (mainly 131 I) radiation sources. Nodule prevalence was markedly higher among women and increased significantly with increasing age at screening and with thyroid volume. Highly significant dose responses were observed for nodule prevalence as a function of total thyroid dose and, in a separate analysis, of doses from internal and external sources as distinct independent variables; dose response was linear for total dose 131 I cf. x ray with respect to thyroid cancer as an endpoint, based on theoretical, experimental, and epidemiological data

  14. The relationship of thyroid cancer with radiation exposure from nuclear weapon testing in the Marshall Islands.

    Science.gov (United States)

    Takahashi, Tatsuya; Schoemaker, Minouk J; Trott, Klaus R; Simon, Steven L; Fujimori, Keisei; Nakashima, Noriaki; Fukao, Akira; Saito, Hiroshi

    2003-03-01

    The US nuclear weapons testing program in the Pacific conducted between 1946 and 1958 resulted in radiation exposure in the Marshall Islands. The potentially widespread radiation exposure from radio-iodines of fallout has raised concerns about the risk of thyroid cancer in the Marshallese population. The most serious exposures and its health hazards resulted from the hydrogen-thermonuclear bomb test, the Castle BRAVO, on March 1, 1954. Between 1993 and 1997, we screened 3,709 Marshallese for thyroid disease who were born before the BRAVO test. It was 60% of the entire population at risk and who were still alive at the time of our examinations. We diagnosed 30 thyroid cancers and found 27 other study participants who had been operated for thyroid cancer before our screening in this group. Fifty-seven Marshallese born before 1954 (1.5%) had thyroid cancer or had been operated for thyroid cancer. Nearly all (92%) of these cancers were papillary carcinoma. We derived estimates of individual thyroid dose proxy from the BRAVO test in 1954 on the basis of published age-specific doses estimated on Utirik atoll and 137Cs deposition levels on the atolls where the participants came from. There was suggestive evidence that the prevalence of thyroid cancer increased with category of estimated dose to the thyroid.

  15. The relationship of thyroid cancer with radiation exposure from nuclear weapon testing in the Marshall Islands

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Tatsuya; Fukao, Akira [Yamagata Univ. (Japan). School of Medicine; Schoemaker, M.J. [Inst. of Cancer Research, Sutton, Surry (United Kingdom); Trott, K.R. [Gray Cancer Inst., Northwood, Middlesex (United Kingdom); Simon, S.L. [National Cancer Inst., Rockville, MD (United States); Fujimori, Keisei; Nakashima, Noriaki [Tohoku Univ., Sendai (Japan). Graduate School of Medicine; Saito, Hiroshi [Nagasaki Univ. (Japan). School of Medicine

    2003-03-01

    The US nuclear weapons testing program in the Pacific conducted between 1946 and 1958 resulted in radiation exposure in the Marshall Islands. The potentially widespread radiation exposure from radioiodines of fallout has raised concerns about the risk of thyroid cancer in the Marshallese population. The most serious exposures and its health hazards resulted from the hydrogen-thermonuclear bomb test, the Castle BRAVO, on March 1, 1954. Between 1993 and 1997, we screened 3,709 Marshallese for thyroid disease who were born before the BRAVO test. It was 60% of the entire population at risk and who were still alive at the time of our examinations. We diagnosed 30 thyroid cancers and found 27 other study participants who had been operated for thyroid cancer before our screening in this group. Fifty-seven Marshallese born before 1954 (1.5%) had thyroid cancer or had been operated for thyroid cancer. Nearly all (92%) of these cancers were papillary carcinoma. We derived estimates of individual thyroid dose proxy from the BRAVO test in 1954 on the basis of published age-specific doses estimated on Utirik atoll and {sup 137}Cs deposition levels on the atolls where the participants came from. There was suggestive evidence that the prevalence of thyroid cancer increased with category of estimated dose to the thyroid. (author)

  16. The relationship of thyroid cancer with radiation exposure from nuclear weapon testing in the Marshall Islands

    International Nuclear Information System (INIS)

    Takahashi, Tatsuya; Fukao, Akira; Trott, K.R.; Simon, S.L.; Fujimori, Keisei; Nakashima, Noriaki; Saito, Hiroshi

    2003-01-01

    The US nuclear weapons testing program in the Pacific conducted between 1946 and 1958 resulted in radiation exposure in the Marshall Islands. The potentially widespread radiation exposure from radioiodines of fallout has raised concerns about the risk of thyroid cancer in the Marshallese population. The most serious exposures and its health hazards resulted from the hydrogen-thermonuclear bomb test, the Castle BRAVO, on March 1, 1954. Between 1993 and 1997, we screened 3,709 Marshallese for thyroid disease who were born before the BRAVO test. It was 60% of the entire population at risk and who were still alive at the time of our examinations. We diagnosed 30 thyroid cancers and found 27 other study participants who had been operated for thyroid cancer before our screening in this group. Fifty-seven Marshallese born before 1954 (1.5%) had thyroid cancer or had been operated for thyroid cancer. Nearly all (92%) of these cancers were papillary carcinoma. We derived estimates of individual thyroid dose proxy from the BRAVO test in 1954 on the basis of published age-specific doses estimated on Utirik atoll and 137 Cs deposition levels on the atolls where the participants came from. There was suggestive evidence that the prevalence of thyroid cancer increased with category of estimated dose to the thyroid. (author)

  17. Dynamic testing for radiation induced failures in a standard CMOS submicron technology pixel front-end

    International Nuclear Information System (INIS)

    Venuto, D. de; Corsi, F.; Ohletz, M.J.

    1999-01-01

    A testing method for the detection of performance degradation induced by high-dose irradiation in high-energy experiments has been developed. The method used is based on a fault signature generation defined on the basis of the state-space analysis for linear circuits. By sampling the response of the circuit under test (CUT) to a single rectangular pulse, a set of parameters α are evaluated which are functions of the circuit singularities and constitute a signature for the CUT. Amplitude perturbations of these parameters engendered by element drift failure indicate a possible faulty condition. The effects of radiation induced faults in the analogue CMOS front-end of a silicon pixel detector employed in high energy physics experiments has been investigated. The results show that, even for the 800 krad dose, the test devised is able to detect the degradation of the amplifier performances. The results show also that hardened devices do not necessarily produce high circuit immunity to radiation and the proposed test method provides a mean to detect these performance deviations and to monitor them during the operating life of the chip. (A.C.)

  18. Design and Test of a Deployable Radiation Cover for the REgolith X-Ray Imaging Spectrometer

    Science.gov (United States)

    Carte, David B.; Inamdar, Niraj K.; Jones, Michael P.; Masterson, Rebecca A.

    2014-01-01

    The REgolith X-ray Imaging Spectrometer (REXIS) instrument contains a one-time deployable radiation cover that is opened using a shape memory alloy actuator (a "Frangibolt") from TiNi Aerospace and two torsion springs. The door will be held closed by the bolt for several years in cold storage during travel to the target asteroid, Bennu, and it is imperative to gain confidence that the door will open at predicted operational temperatures. This paper briefly covers the main design features of the radiation cover and measures taken to mitigate risks to cover deployment. As the chosen FD04 model Frangibolt actuator has minimal flight heritage, the main focus of this paper is the testing, results and conclusions with the FD04 while discussing key lessons learned with respect to the use of the FD04 actuator in this application.

  19. The Plateau de Bure ASTEP Platform Test in natural radiation environment of electronic components and circuits

    International Nuclear Information System (INIS)

    Autran, J.L.; Munteanu, D.; Sauze, S.; Roche, Ph.; Gasiot, G.; Borel, J.

    2010-01-01

    Reducing the size of microelectronic devices and increasing the integration density of circuits lead (following the famous Moore's law) to an increased sensitivity of circuits to natural terrestrial radiation environment. - Such sensitivity to atmospheric particles (mainly neutrons) can cause non-destructive (soft-errors) or destructive (latch-up) failures in most electronic circuits, including volatile static memories (SRAM), object of the research work carried out since 2004 on the European Test Platform ASTER. - This paper presents in details the ASTEP platform, its location, the instruments (neutron monitor of the Plateau de Bure) and the experiences (memory tester) currently installed on the Plateau de Bure. In a second part, we also report a synthesis of the key results concerning the natural radiation sensitivity of SRAM fabricated in 130 nm and 65 nm bulk silicon technologies. (authors)

  20. Characterization and radiation studies of diode test structures in LFoundry CMOS technology

    Energy Technology Data Exchange (ETDEWEB)

    Daas, Michael; Gonella, Laura; Hemperek, Tomasz; Huegging, Fabian; Krueger, Hans; Pohl, David-Leon; Wermes, Norbert [Physikalisches Institut der Universitaet Bonn (Germany); Macchiolo, Anna [Max-Planck-Institut fuer Physik, Muenchen (Germany)

    2016-07-01

    In order to prepare for the High Luminosity upgrade of the LHC, all subdetector systems of the ATLAS experiment will be upgraded. In preparation for this process, different possibilities for new radiation-hard and cost-efficient silicon sensor technologies to be used as part of hybrid pixel detectors in the ATLAS inner tracker are being investigated. One promising way to optimize the cost-efficiency of silicon-based pixel detectors is to use commercially available CMOS technologies such as the 150 nm process by LFoundry. In this talk, several CMOS pixel test structures, such as simple diodes and small pixel arrays, that were manufactured in this technology are characterized regarding general performance and radiation hardness and compared to each other as well as to the current ATLAS pixel detector.

  1. Radiative Heating in MSL Entry: Comparison of Flight Heating Discrepancy to Ground Test and Predictive Models

    Science.gov (United States)

    Cruden, Brett A.; Brandis, Aaron M.; White, Todd R.; Mahzari, Milad; Bose, Deepak

    2014-01-01

    During the recent entry of the Mars Science Laboratory (MSL), the heat shield was equipped with thermocouple stacks to measure in-depth heating of the thermal protection system (TPS). When only convective heating was considered, the derived heat flux from gauges in the stagnation region was found to be underpredicted by as much as 17 W/sq cm, which is significant compared to the peak heating of 32 W/sq cm. In order to quantify the contribution of radiative heating phenomena to the discrepancy, ground tests and predictive simulations that replicated the MSL entry trajectory were performed. An analysis is carried through to assess the quality of the radiation model and the impact to stagnation line heating. The impact is shown to be significant, but does not fully explain the heating discrepancy.

  2. A rapid and simple screening test to detect the radiation treatment of fat-containing foods

    International Nuclear Information System (INIS)

    Delincee, H.

    1993-01-01

    In recent years several international efforts have been made to develop analytical detection methods for the radiation treatment of foods. A number of methods has indeed been developed. Particularly, for fat-containing foods several methods are already in an advanced stage. In addition to the sophisticated techniques such as gas chromatography/mass spectrometry which require relatively expensive equipment and/or extended sample preparation time, it would be desirable to have quick and simple screening tests, which immediately on-the-spot give some indication whether a food product has been irradiated or not. A solution to this problem for lipid-containing foods has been put forward by Furuta and co-workers (1991, 1992), who estimated the amount of carbon monoxide originating from the lipid fraction in poultry meat after irradiation. The carbon monoxide was expelled from the frozen meat by quick microwave heating and in the head space of the sample, the formed carbon monoxide was determined by gas chromatography. In order to speed up time of analysis, we have used an electrochemical CO sensor, as also is being used to estimate CO in ambient air in workplaces, to determine the CO content in the vapor expelled from the irradiated samples. This CO test is very simple, cheap and easy to perform. It takes only a few minutes to screen food samples for evidence of their having been radiation processed. If doubts concerning the radiation treatment of a sample arise, the more sophisticated - and expensive -methods for analyzing lipid-containing foods can be applied. Certainly the test is limited to food products which contain a certain amount of fat. A preliminary test with lean shrimps showed practically no difference between irradiated (2.5 and 5 kGy) and non-irradiated samples. By relating CO production to the fat content, possibly a better parameter for classification can be obtained. (orig./vhe)

  3. Report of the actual conditions of the radiation exposed residents near the former Semipalatinsk nuclear test site

    International Nuclear Information System (INIS)

    Kawano, Noriyuki; Taooka, Yasuyuki; Hiraoka, Takashi; Hoshi, Masaharu; Shaimardanovich, Z.Z.

    2004-01-01

    Hiroshima Peace Science Consortium, established in 2002 as part of the local cooperation project of Hiroshima University for peace science, conducted a field research in Semipalatinsk and related areas in 2002 to collect and analyze data on health effects of radiation experiences of people exposed to nuclear test radiation. This book is a report of the research and contains Introductory remarks; 6 chapters of Overview of the study, Medical information analysis on the radiation exposed residents near the former Semipalatinsk nuclear test site using questionnaire, Content analysis of testimonies written by hibakusha near the nuclear test site of Semipalatinsk, Comments on the interview, Significance of collecting testimonies of those exposed to radiation in Semipalatinsk, Kazakhstan/in comparison with those of Hiroshima and Nagasaki, and Future tasks and prospective; Conclusion; and 2 Appendices of Research on the conditions of radiation exposure survey response sheet and Testimonies. (N.I.)

  4. Possibility of use of plant test systems for estimation of degree risk at radiation influence

    International Nuclear Information System (INIS)

    Gogebashvili, M.E; Ivanishvili, N.I.

    2011-01-01

    (in some cases, frequency of occurrence) negative event (irradiation), a damage (number of deviations from norm or deadly outcomes) at event realization. The biological model offered by us in essence is a version of expert judgments of an estimation of risk, at radiating influence. Thus from positions of practical application of this test system to become important and that, how much this influence is modified by various concomitant factors.In whole, as a result of the spent researches it is shown, that the given model can serve as convenient test system at studying of the remote effects of radiation and definition of degree of risk at their formation.

  5. Environmental radiation measurements at the former Soviet Union's Semipalatinsk nuclear test site and surrounding villages

    International Nuclear Information System (INIS)

    Shebell, P.; Hutter, A.R.

    1996-07-01

    Two scientists from the U.S. Department of Energy's Environmental Measurements Laboratory served as scientific experts to the International Atomic Energy Agency's (IAEA) Mission to Kazakhstan: Strengthening Radiation and Nuclear Safety Infrastructures in Countries of the former USSR, Special Task - Preassessment of the radiological situation in the Semipalatinsk and western areas of Kazakhstan. The former Soviet Union's largest nuclear test site was located near Semipalatinsk, Kazakhstan, and following Kazakhstan's independence, the IAEA committed to studying the environmental contamination and the resulting radiation exposure risk to the population due to 346 underground, 87 atmospheric and 26 surface nuclear detonations performed at the site between 1949 and 1989. As part of an 11-member team, environmental radiation measurements were performed during 2 weeks in July 1994. Approximately 30 sites were visited both within the boundaries of the Semipalatinsk nuclear test site as well as in and around surrounding villages. Specifically, the objectives of the EML team were to apply independent methods and equipment to assess potential current radiation exposures to the population. Towards this end, the EML scientists collected in-situ gamma-ray spectra, performed external gamma dose rate measurements using pressurized ionization chambers, and collected soil samples in order to estimate the inventory and to determine the depth distribution of radionuclides of interest. With the exception of an area near an open-quotes atomic lakeclose quotes and a 1 km 2 area encompassing ground zero, all the areas visited by the team had external dose rates that were within typical environmental levels. The measurements taken within a 15 km radius of ground zero had elevated levels of 137 Cs as well as the activation products 152 Eu and 60 Co, The dose rate within a 1 km radius of ground zero ranged from 500 to 30000 nGy h -1

  6. Radiation Tests on the Complete System of the Instrumentation of the LHC Cryogenics at the CERN Neutrinos to Gran Sasso (CNGS) Test Facility

    CERN Document Server

    Gousiou, E; Casas Cubillos, J; de la Gama Serrano, J

    2009-01-01

    There are more than 6000 electronic cards for the instrumentation of the LHC cryogenics, housed in crates and distributed around the 27 km tunnel. Cards and crates will be exposed to a complex radiation field during the 10 years of LHC operation. Rad-tol COTS and rad-hard ASIC have been selected and individually qualified during the design phase of the cards. The test setup and the acquired data presented in this paper target the qualitative assessment of the compliance with the LHC radiation environment of an assembled system. It is carried out at the CNGS test facility which provides exposure to LHC-like radiation field.

  7. Command and Data Handling Flight Software test framework: A Radiation Belt Storm Probes practice

    Science.gov (United States)

    Hill, T. A.; Reid, W. M.; Wortman, K. A.

    During the Radiation Belt Storm Probes (RBSP) mission, a test framework was developed by the Embedded Applications Group in the Space Department at the Johns Hopkins Applied Physics Laboratory (APL). The test framework is implemented for verification of the Command and Data Handling (C& DH) Flight Software. The RBSP C& DH Flight Software consists of applications developed for use with Goddard Space Flight Center's core Flight Executive (cFE) architecture. The test framework's initial concept originated with tests developed for verification of the Autonomy rules that execute with the Autonomy Engine application of the RBSP C& DH Flight Software. The test framework was adopted and expanded for system and requirements verification of the RBSP C& DH Flight Software. During the evolution of the RBSP C& DH Flight Software test framework design, a set of script conventions and a script library were developed. The script conventions and library eased integration of system and requirements verification tests into a comprehensive automated test suite. The comprehensive test suite is currently being used to verify releases of the RBSP C& DH Flight Software. In addition to providing the details and benefits of the test framework, the discussion will include several lessons learned throughout the verification process of RBSP C& DH Flight Software. Our next mission, Solar Probe Plus (SPP), will use the cFE architecture for the C& DH Flight Software. SPP also plans to use the same ground system as RBSP. Many of the RBSP C& DH Flight Software applications are reusable on the SPP mission, therefore there is potential for test design and test framework reuse for system and requirements verification.

  8. Radiations

    International Nuclear Information System (INIS)

    Pujol Mora, J.

    1999-01-01

    The exposition to ionizing radiations is a constant fact in the life of the human being and its utilization as diagnostic and therapeutic method is generalized. However, it is notorious how as years go on, the fear to the ionizing radiation seems to persist too, and this fact is not limited to the common individual, but to the technical personnel and professional personnel that labors with them same. (S. Grainger) [es

  9. Radiation

    International Nuclear Information System (INIS)

    Davidson, J.H.

    1986-01-01

    The basic facts about radiation are explained, along with some simple and natural ways of combating its ill-effects, based on ancient healing wisdom as well as the latest biochemical and technological research. Details are also given of the diet that saved thousands of lives in Nagasaki after the Atomic bomb attack. Special comment is made on the use of radiation for food processing. (U.K.)

  10. Electrochromic Radiator Coupon Level Testing and Full Scale Thermal Math Modeling for Use on Altair Lunar Lander

    Science.gov (United States)

    Bannon, Erika T.; Bower, Chad E.; Sheth, Rubik; Stephan, Ryan

    2010-01-01

    In order to control system and component temperatures, many spacecraft thermal control systems use a radiator coupled with a pumped fluid loop to reject waste heat from the vehicle. Since heat loads and radiation environments can vary considerably according to mission phase, the thermal control system must be able to vary the heat rejection. The ability to "turn down" the heat rejected from the thermal control system is critically important when designing the system. Electrochromic technology as a radiator coating is being investigated to vary the amount of heat rejected by a radiator. Coupon level tests were performed to test the feasibility of this technology. Furthermore, thermal math models were developed to better understand the turndown ratios required by full scale radiator architectures to handle the various operation scenarios encountered during a mission profile for the Altair Lunar Lander. This paper summarizes results from coupon level tests as well as the thermal math models developed to investigate how electrochromics can be used to increase turn down ratios for a radiator. Data from the various design concepts of radiators and their architectures are outlined. Recommendations are made on which electrochromic radiator concept should be carried further for future thermal vacuum testing.

  11. Test-beam Results from a RICH Detector Prototype Using Aerogel Radiator and Pixel Hybrid Photon Detectors

    CERN Document Server

    Aglieri-Rinella, G; Van Lysebetten, A; Piedigrossi, D; Wyllie, K; Bellunato, T F; Calvi, M; Matteuzzi, C; Musy, M; Perego, D L; Somerville, L P; Newby, C; Easo, S; Wotton, S

    2006-01-01

    A test-beam study was performed at CERN with a Ring Imaging Cherenkov (RICH) prototype using three pixel Hybrid Photon Detectors. Results on the photon yield and Cherenkov angle resolution are presented here, for the Aerogel radiator and also for reference runs taken with Nitrogen radiator.

  12. The effects of radiation on various materials and the qualification tests required for their use in medical devices

    International Nuclear Information System (INIS)

    Landfield, H.

    1980-01-01

    Many polymers used in the medical field show various degrees of degradation after radiation exposure either by visual or physical measurements. The general effects of radiation on such medical polymers are reviewed and discussed as well as the tests used to qualify their performance. (author)

  13. Reliability test: X-ray ring exit chambers crotch radiation absorbers. Final report

    International Nuclear Information System (INIS)

    Lynch, D.R.; Morgan, J.

    1999-01-01

    This report details the efforts by engineers at the National Synchrotron Light Source (NSLS) of Brookhaven National Laboratory (BNL) to evaluate the reliability of water-cooled radiation absorbers used in the NSLS X-ray ring. These absorbers are part of the 16 dipole vacuum chambers which comprise the arc sections of the ring. They are located at the intersections (crotch) of the beamline exit ports with the electron beam chamber, and are commonly referred to as crotches. The purpose of these efforts was to demonstrate the reliability of the crotches under operating conditions that the crotches will be subjected to over the entire expected life of the ring. The efforts described include engineering calculations, finite element analysis, conceptual design for a reliability test, test implementation and descriptions, results and conclusions related to these analyses and tests

  14. Image dissector photocathode solar damage test program. [solar radiation shielding using a fast optical lens

    Science.gov (United States)

    Smith, R. A.

    1977-01-01

    Image dissector sensors of the same type which will be used in the NASA shuttle star tracker were used in a series of tests directed towards obtaining solar radiation/time damage criteria. Data were evaluated to determine the predicted level of operability of the star tracker if tube damage became a reality. During the test series a technique for reducing the solar damage effect was conceived and verified. The damage concepts are outlined and the test methods and data obtained which were used for verification of the technique's feasibility are presented. The ability to operate an image dissector sensor with the solar image focussed on the photocathode by a fast optical lens under certain conditions is feasible and the elimination of a mechanical protection device is possible.

  15. Offsite environmental monitoring report. Radiation monitoring around United States nuclear test areas, calendar year 1981

    International Nuclear Information System (INIS)

    Black, S.C.; Grossman, R.F.; Mullen, A.A.; Potter, G.D.; Smith, D.D.; Hopper, J.L.

    1982-08-01

    This report, prepared in accordance with the guidelines in DOE/E-0023 (DOE 1981), covers the program activities conducted around Nevada Test Site (NTS) for calendar year 1981. It contains descriptions of pertinent features of the NTS and its environs, summaries of the dosimetry and sampling methods, analytical procedures, and the analytical results from environmental measurements. Where applicable, dosimetry and sampling data are compared to appropriate guides for external and internal exposures of humans to ionizing radiation. The monitoring networks detected no radioactivity in the various media which could be attributed to US nuclear testing. Small amounts of fission products were detected in air samples as a result of the People's Republic of China nuclear test and atmospheric krypton-85 increased, following the trend beginning in 1960, due to increased use of nuclear technology. Strontium-90 in milk and cesium-137 in meat samples continued the slow decline as observed for the last several years

  16. Offsite environmental monitoring report. Radiation monitoring around United States nuclear test areas, calendar year 1981

    Energy Technology Data Exchange (ETDEWEB)

    Black, S.C.; Grossman, R.F.; Mullen, A.A.; Potter, G.D.; Smith, D.D.; Hopper, J.L. (comps.)

    1982-08-01

    This report, prepared in accordance with the guidelines in DOE/E-0023 (DOE 1981), covers the program activities conducted around Nevada Test Site (NTS) for calendar year 1981. It contains descriptions of pertinent features of the NTS and its environs, summaries of the dosimetry and sampling methods, analytical procedures, and the analytical results from environmental measurements. Where applicable, dosimetry and sampling data are compared to appropriate guides for external and internal exposures of humans to ionizing radiation. The monitoring networks detected no radioactivity in the various media which could be attributed to US nuclear testing. Small amounts of fission products were detected in air samples as a result of the People's Republic of China nuclear test and atmospheric krypton-85 increased, following the trend beginning in 1960, due to increased use of nuclear technology. Strontium-90 in milk and cesium-137 in meat samples continued the slow decline as observed for the last several years.

  17. In situ mechanical-radiation effects test capsule for simulating fusion material environments

    International Nuclear Information System (INIS)

    Christensen, K.E.; Bennett, G.A.; Sommer, W.F.

    1981-01-01

    Conditions of radiation and simultaneous cyclic stress on materials are inherent in advanced energy source designs such as inertially and magnetically confined controlled thermonuclear reactors. A test capsule capable of applying a cyclic stress to test specimens while they are being irradiated in the 800-MeV proton beam at the Clinton P. Anderson Los Alamos Meson Physics Facility has been developed. The design and performance of this device are discussed in this report. This machine has facilities for seven pairs of differential samples; one sample of a pair receives an applied cyclic stress and its companion in an identical flux will be the unstressed control. Control of the sample temperature and in situ monitoring of sample elongation and load are provided in the design. Results of an earlier experiment will be discussed, along with those of preliminary bench tests of the redesigned capsule

  18. Radiation

    International Nuclear Information System (INIS)

    Winther, J.F.; Ulbak, K.; Dreyer, L.; Pukkala, E.; Oesterlind, A.

    1997-01-01

    Exposure to solar and ionizing radiation increases the risk for cancer in humans. Some 5% of solar radiation is within the ultraviolet spectrum and may cause both malignant melanoma and non-melanocytic skin cancer; the latter is regarded as a benign disease and is accordingly not included in our estimation of avoidable cancers. Under the assumption that the rate of occurrence of malignant melanoma of the buttocks of both men and women and of the scalp of women would apply to all parts of the body in people completely unexposed to solar radiation, it was estimated that approximately 95% of all malignant melanomas arising in the Nordic populations around the year 2000 will be due to exposure to natural ultraviolet radiation, equivalent to an annual number of about 4700 cases, with 2100 in men and 2600 in women, or some 4% of all cancers notified. Exposure to ionizing radiation in the Nordic countries occurs at an average effective dose per capita per year of about 3 mSv (Iceland, 1.1 mSv) from natural sources, and about 1 mSv from man-made sources. While the natural sources are primarily radon in indoor air, natural radionuclides in food, cosmic radiation and gamma radiation from soil and building materials, the man-made sources are dominated by the diagnostic and therapeutic use of ionizing radiation. On the basis of measured levels of radon in Nordic dwellings and associated risk estimates for lung cancer derived from well-conducted epidemiological studies, we estimated that about 180 cases of lung cancer (1% of all lung cancer cases) per year could be avoided in the Nordic countries around the year 2000 if indoor exposure to radon were eliminated, and that an additional 720 cases (6%) could be avoided annually if either radon or tobacco smoking were eliminated. Similarly, it was estimated that the exposure of the Nordic populations to natural sources of ionizing radiation other than radon and to medical sources will each give rise to an annual total of 2120

  19. Radiation tests on service electronics for future multi TeV detectors

    International Nuclear Information System (INIS)

    Larsen, H.; Schoenbacher, H.; Massam, T.; Wulf, F.

    1993-01-01

    Irradiation tests of a number of essential components for use in the service electronics of the Leading Proton Spectrometer (LPS) have been undertaken. The components are simple medium-scale integrated circuits such as Transistor Transistor Logic (TTL) buffers from the Advanced Low-power Schottky (ALS), Low-power Schottky (LS), and Fast (F) families, optocouplers, and balanced line drivers and receivers. More complex circuits, such as a Fuse Programmable Array Logic chip, programmed as a 6-bit counter, and a complete switched-mode power supply unit were also tested. Further, monolithic voltage regulators with an output potential of 5 V, and 10 MHz quartz oscillator hybrids were tested. The different radiation fields were X-rays (80 keV), 60 Co gamma rays, electrons (2.5 MeV), and a high-energy proton accelerator environment. Depending on the device degradation, the maximum dose was up to 0.8 MGy. It is shown that the simple choice of circuit family can achieve a hardness level of nearly 1 MGy(Si), provided that one is prepared to make some sacrifices in power consumption, and in speed. It has been found that this radiation hardness can be reached with LS technology. The maximum level of about 1 MGy(Si) was obtained with 2.5 MeV electrons, which is equivalent to a 1 MeV neutron fluence of the order of 6x10 13 n/cm 2 . (orig.)

  20. Radiation exposure and health damage of residents at Semipalatinsk nuclear test site

    International Nuclear Information System (INIS)

    Tolebay, Rakhypbekov; Noso, Yoshihiro; Takechi, Nobuo

    2016-01-01

    Although the nuclear test site of Semipalatinsk (former Soviet Union and presently the Republic of Kazakhstan) stopped nuclear tests 25 years ago, there are presumably more than 200,000 victims near the site, including persons with a low dose and a high dose. Semey Medical University and Shimane University, together with the Kazakh Scientific Institute for Radiation Medicine and Ecology, have been conducting the measurement of radiation concentration of soil and the thyroid screening of residents. The following were surveyed: (1) chromosomal abnormality for 55 female residents (average 45 years in age) in heavily polluted areas and 25 female residents (average 42 years in age) in non-polluted areas, (2) mental abnormality of residents in polluted areas and non-polluted areas of Semey City, and (3) changes in the frequency of surgery cases for cancer between 1989 and 2014 at Semey Medical University Cancer Center. As for chromosomal abnormality, 3-5 times many mutation cases were observed in heavily polluted areas than in non-polluted areas. The nodules of thyroid gland were four times more frequent in heavily polluted areas. The frequency of a whole variety of cancers was nearly twice in polluted areas compared with in non-polluted areas, most of which were digestive system cancer, lung cancer, and breast cancer in the order. The frequency of mental abnormality has also increased nearly twice as compared to non-polluted areas, and it included neurological disorder, adjustment disorder, neuralgia, moderate depression, and learning disability. These results suggest that some physical effects can be caused by exposure. In the future, this study will investigate the effects of radiation exposure at the nuclear test site. (A.O.)

  1. Silicon photo-multiplier radiation hardness tests with a beam controlled neutron source

    International Nuclear Information System (INIS)

    Angelone, M.; Pillon, M.; Faccini, R.; Pinci, D.; Baldini, W.; Calabrese, R.; Cibinetto, G.; Cotta Ramusino, A.; Malaguti, R.; Pozzati, M.

    2010-01-01

    Radiation hardness tests were performed at the Frascati Neutron Generator on silicon Photo-Multipliers that were made of semiconductor photon detectors built from a square matrix of avalanche photo-diodes on a silicon substrate. Several samples from different manufacturers have been irradiated, integrating up to 7x10 10 1-MeV-equivalent neutrons per cm 2 . Detector performance was recorded during the neutron irradiation, and a gradual deterioration of their properties began after an integrated fluence of the order of 10 8 1-MeV-equivalent neutrons per cm 2 was reached.

  2. Planned High-brightness Channeling Radiation Experiment at Fermilab's Advanced Superconducting Test Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Blomberg, Ben [NICADD, DeKalb; Mihalcea, Daniel [NICADD, DeKalb; Panuganti, Harsha [NICADD, DeKalb; Piot, Philippe [Fermilab; Brau, Charles [Vanderbilt U.; Choi, Bo [Vanderbilt U.; Gabella, William [Vanderbilt U.; Ivanov, Borislav [Vanderbilt U.; Mendenhall, Marcus [Vanderbilt U.; Lynn, Christopher [Swarthmore Coll.; Sen, Tanaji [Fermilab; Wagner, Wolfgang [Forschungszentrum Dresden Rossendorf

    2014-07-01

    In this contribution we describe the technical details and experimental setup of our study aimed at producing high-brightness channeling radiation (CR) at Fermilab’s new user facility the Advanced Superconducting Test Accelerator (ASTA). In the ASTA photoinjector area electrons are accelerated up to 40-MeV and focused to a sub-micron spot on a ~40 micron thick carbon diamond, the electrons channel through the crystal and emit CR up to 80-KeV. Our study utilizes ASTA’s long pulse train capabilities and ability to preserve ultra-low emittance, to produce the desired high average brightness.

  3. Accelerated aging tests of radiation damaged lasers and photodiodes for the CMS tracker optical links

    CERN Document Server

    Gill, K; Batten, J; Cervelli, G; Grabit, R; Jensen, F; Troska, Jan K; Vasey, F

    1999-01-01

    The combined effects of radiation damage and accelerated ageing in COTS lasers and p-i-n photodiodes are presented. Large numbers of these devices are employed in future High Energy Physics experiments and it is vital that these devices are confirmed to be sufficiently robust in terms of both radiation resistance and reliability. Forty 1310 nm InGaAsP edge-emitting lasers (20 irradiated) and 30 InGaAs p- i-n photodiodes (19 irradiated) were aged for 4000 hours at 80 degrees C with periodic measurements made of laser threshold and efficiency, in addition to p-i-n leakage current and photocurrent. There were no sudden failures and there was very little wearout- related degradation in either unirradiated or irradiated sample groups. The results suggest that the tested devices have a sufficiently long lifetime to operate for at least 10 years inside the Compact Muon Solenoid experiment despite being exposed to a harsh radiation environment. (13 refs).

  4. Possibility of use of plat test systems for estimation of degree risk at radiation influence

    International Nuclear Information System (INIS)

    Gogebashvili, M.E.; Ivanishvili, N.I.

    2010-01-01

    . The biological model in essence is a version of expert judgments of an estimation of risk, at radiating influence. Thus from positions of practical application of this test system to become important and that, how much this influence is modified by various concomitant factors. In whole, as a result of the spent researches it is shown, that the given model can serve as convenient test system at studying of the remote effects of radiation and definition of degree of risk at their formation.

  5. Tests of the linearity assumption in the dose-effect relationship for radiation-induced cancer

    International Nuclear Information System (INIS)

    Cohen, A.F.; Cohen, B.L.

    1980-01-01

    The validity of the BEIR linear extrapolation to low doses of the dose-effect relationship for radiation induced cancer is tested by use of natural radiation making use of selectivity on type of cancer, smoking habits, sex, age group, geographic area and/or time period. For lung cancer, a linear interpolation between zero dose-zero effect and the data from radon-induced cancers in miners implies that the majority of all lung cancers among non-smokers are due to radon; since lung cancers in miners are mostly small-cell undifferentiated (SCU), a rather rare type in general, linearity over predicts the frequency of SCU lung cancers among non smokers by a factor of 10, and among non-smoking females age 25-44 by a factor of 24. Similarly, linearity predicts that the majority of all lung cancers early in this century were due to radon even after due consideration is given to cases missed by poor diagnostic efficiency (this matter is considered in some detail). For the 30-40 age range, linearity over predicts the total lung cancer rate at that time by a factor of 3-6; for SCU lung cancer, the over-prediction is by at least a factor of 10. Other causes of lung cancer are considered which further enhance the degree to which the linearity assumption over-estimates the effects of low level radiation. A similar analysis is applied to leukemia induced by natural radiation. It is concluded that the upper limit for this is not higher than estimates from the linearity hypothesis. (author)

  6. Radiation monitoring data on the power-up test of HTTR. Results up to 20 MW operation

    International Nuclear Information System (INIS)

    Ashikagaya, Yoshinobu; Nakazawa, Takashi; Yoshino, Toshiaki; Yasu, Katsuji

    2002-01-01

    The High Temperature Engineering Test Reactor (HTTR) have completed the Power-up test of 9 MW (the single and parallel loaded operation) in the rated operation mode. After that the Power-up test in the rated operation mode and the high-temperature test operation mode with a thermal output of 20 MW (the single and parallel loaded operation) were performed between January 16, 2001 and June 10, 2001. This report describes the radiation monitoring data carried out during the HTTR Power-up test in the rated operation mode and the high-temperature test operation mode with a thermal output of 20 MW. The followings were concluded from these radiation monitoring data. The monitoring of radioactive gaseous effluents and the radiation protection for the works will be easy to do and the exposure dose of the workers will be kept the low level. (author)

  7. Tests for radiation protection in X-Ray mammography room for professional and non-professional exposure

    International Nuclear Information System (INIS)

    Naidenov, I.; Skocheva, A.

    2006-01-01

    Full text: Control tests for radiation protection of medical diagnostic rooms in our country are based on the guidelines to the use of x-rays in medicine and on the basic safety standards for radiation protection. The mammography room tests are not supported by basic data (such as normal conditions for testing and secondary limits) which to allow the developing of methods as the case is with the conventional x-ray rooms. The material presents and discusses over the situation of the matter with the aim to find solution of the problem. In mammography units the space distribution of the dose field of the object scattering radiation is not symmetrical, the maximum being in a direction opposite to the primary beam. Control tests were made for stray radiation in major (in the plane of beam rotation) test points in five rooms with mammography units of different producers and generation, under angles of scattering from the direction of the beam of 900 (horizontal table - 0 deg projection) and 1630 (tilt table - 730 deg projection). The results on the stray radiation show up to four times higher values in the 730 projection, the remaining conditions being the same. Normalization to the week loading used in the shielding design, like the comparison with secondary limits as published in the available norms do not give unambiguous idea. It is advisable to use this projection in control tests for radiation protection and the values shall be compared with the secondary limits of the corresponding standard loading

  8. A scintillation testing technology at a viewpoint of optical test. At a memory of winning of the Radiation Prize (Prize of Encouragement)

    International Nuclear Information System (INIS)

    Maekawa, Tatsuyuki

    2000-01-01

    In a 'summer school' held at Matsushima, a series of developmental results had been introduced on a wavelength shift type beta-ray detector and others recently progressed by author at a viewpoint of 'new reconsideration on scintillation testing, one of the oldest radiation testing technology for an optical testing'. As a chance to write this theme again was obtained at present, here were introduced on trial and errors, backgrounds on ideas, pains for trial production and so forth at a process of putting together them for actual technologies and products under combining a series of ideas with their needs. Here were newly introduced on developmental backgrounds, points for practicability, and so forth on optical radiation testing technology which had been developed by authors. By upgrading of radiation resistance on the optical fibers themselves, developments for not only radiation testing but also instrumentation in storage vessel specific to nuclear instrumentation are considered in future. And, some findings on new elements and techniques, such as application of radiation to refractive index change due to much minute exotherm, application of Cherenkov phenomenon in glass, fiber grating and interference test assembles a minute diffraction lattice into a core, and so forth are found recently, which will be expected for their future developments. (G.K.)

  9. A scintillation testing technology at a viewpoint of optical test. At a memory of winning of the Radiation Prize (Prize of Encouragement)

    Energy Technology Data Exchange (ETDEWEB)

    Maekawa, Tatsuyuki [Toshiba Corp., Kawasaki, Kanagawa (Japan)

    2000-04-01

    In a 'summer school' held at Matsushima, a series of developmental results had been introduced on a wavelength shift type beta-ray detector and others recently progressed by author at a viewpoint of 'new reconsideration on scintillation testing, one of the oldest radiation testing technology for an optical testing'. As a chance to write this theme again was obtained at present, here were introduced on trial and errors, backgrounds on ideas, pains for trial production and so forth at a process of putting together them for actual technologies and products under combining a series of ideas with their needs. Here were newly introduced on developmental backgrounds, points for practicability, and so forth on optical radiation testing technology which had been developed by authors. By upgrading of radiation resistance on the optical fibers themselves, developments for not only radiation testing but also instrumentation in storage vessel specific to nuclear instrumentation are considered in future. And, some findings on new elements and techniques, such as application of radiation to refractive index change due to much minute exotherm, application of Cherenkov phenomenon in glass, fiber grating and interference test assembles a minute diffraction lattice into a core, and so forth are found recently, which will be expected for their future developments. (G.K.)

  10. Niche evolution and adaptive radiation: Testing the order of trait divergence

    Science.gov (United States)

    Ackerly, D.D.; Schwilk, D.W.; Webb, C.O.

    2006-01-01

    In the course of an adaptive radiation, the evolution of niche parameters is of particular interest for understanding modes of speciation and the consequences for coexistence of related species within communities. We pose a general question: In the course of an evolutionary radiation, do traits related to within-community niche differences (?? niche) evolve before or after differentiation of macrohabitat affinity or climatic tolerances (?? niche)? Here we introduce a new test to address this question, based on a modification of the method of independent contrasts. The divergence order test (DOT) is based on the average age of the nodes on a tree, weighted by the absolute magnitude of the contrast at each node for a particular trait. The comparison of these weighted averages reveals whether large divergences for one trait have occurred earlier or later in the course of diversification, relative to a second trait; significance is determined by bootstrapping from maximum-likelihood ancestral state reconstructions. The method is applied to the evolution of Ceanothus, a woody plant group in California, in which co-occurring species exhibit significant differences in a key leaf trait (specific leaf area) associated with contrasting physiological and life history strategies. Co-occurring species differ more for this trait than expected under a null model of community assembly. This ?? niche difference evolved early in the divergence of two major subclades within Ceanothus, whereas climatic distributions (?? niche traits) diversified later within each of the subclades. However, rapid evolution of climate parameters makes inferences of early divergence events highly uncertain, and differentiation of the ?? niche might have taken place throughout the evolution of the group, without leaving a clear phylogenetic signal. Similar patterns observed in several plant and animal groups suggest that early divergence of ?? niche traits might be a common feature of niche evolution in

  11. Recent progress and tests of radiation resistant impregnation materials for Nb3Sn coils

    Science.gov (United States)

    Bossert, R.; Krave, S.; Ambrosio, G.; Andreev, N.; Chlachidze, G.; Nobrega, A.; Novitski, I.; Yu, M.; Zlobin, A. V.

    2014-01-01

    Fermilab is collaborating with Lawrence Berkeley National Laboratory (LBNL) and Brookhaven National Laboratory (BNL) (US-LARP collaboration) to develop a large-aperture Nb3Sn superconducting quadrupole for the Large Hadron Collider (LHC) luminosity upgrade. An important component of this work is the development of materials that are sufficiently radiation resistant for use in critical areas of the upgrade. This paper describes recent progress in characterization of materials, including the baseline CTD101K epoxy, cyanate ester blends, and Matrimid 5292, a bismaleimide-based system. Structural properties of "ten stacks" of cable impregnated with these materials are tested at room and cryogenic temperatures and compared to the baseline CT-101K. Experience with potting 1 and 2 meter long coils with Matrimid 5292 are described. Test results of a single 1-m coil impregnated with Matrimid 5292 are reported and compared to similar coils impregnated with the traditional epoxy.

  12. Development of a synchrotron radiation beam monitor for the Integrable Optics Test Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Scarpelli, Andrea [Univ. of Ferrara (Italy)

    2016-01-01

    Nonlinear integrable optics applied to beam dynamics may mitigate multi-particle instabilities, but proof of principle experiments have never been carried out. The Integrable Optics Test Accelerator (IOTA) is an electron and proton storage ring currently being built at Fermilab, which addresses tests of nonlinear lattice elements in a real machine in addition to experiments on optical stochastic cooling and on the single-electron wave function. These experiments require an outstanding control over the lattice parameters, achievable with fast and precise beam monitoring systems. This work describes the steps for designing and building a beam monitor for IOTA based on synchrotron radiation, able to measure intensity, position and transverse cross-section beam.

  13. Recent progress and tests of radiation resistant impregnation materials for Nb3Sn coils

    International Nuclear Information System (INIS)

    Bossert, R.; Krave, S.; Ambrosio, G.; Andreev, N.; Chlachidze, G.; Nobrega, A.; Novitski, I.; Yu, M.; Zlobin, A. V.

    2014-01-01

    Fermilab is collaborating with Lawrence Berkeley National Laboratory (LBNL) and Brookhaven National Laboratory (BNL) (US-LARP collaboration) to develop a large-aperture Nb 3 Sn superconducting quadrupole for the Large Hadron Collider (LHC) luminosity upgrade. An important component of this work is the development of materials that are sufficiently radiation resistant for use in critical areas of the upgrade. This paper describes recent progress in characterization of materials, including the baseline CTD101K epoxy, cyanate ester blends, and Matrimid 5292, a bismaleimide-based system. Structural properties of “ten stacks” of cable impregnated with these materials are tested at room and cryogenic temperatures and compared to the baseline CT-101K. Experience with potting 1 and 2 meter long coils with Matrimid 5292 are described. Test results of a single 1-m coil impregnated with Matrimid 5292 are reported and compared to similar coils impregnated with the traditional epoxy

  14. The design, build and test of a digital analyzer for mixed radiation fields

    International Nuclear Information System (INIS)

    Joyce, M. J.; Aspinall, M. D.; Georgopoulos, K.; Cave, F. D.; Jarrah, Z.

    2009-01-01

    The design, build and test of a digital analyzer for mixed radiation fields is described. This instrument has been developed to provide portable, real-time discrimination of hard mixed fields comprising both neutrons and γ rays with energies typically above 0.5 MeV. The instrument in its standard form comprises a sensor head and a system unit, and affords the flexibility to provide processed data in the form of the traditional scatter-plot representation separating neutron and γ-ray components, or the full, sampled pulse data itself. The instrument has been tested with an americium-beryllium source in three different shielding arrangements to replicate the case in which there are only neutrons, only γ rays and where both neutrons and γ-rays are present. The instrument is observed to return consistent results. (authors)

  15. Renal oncocytoma: experience of Clinical Urology A, Urology Department, CHU Ibn Sina, Rabat, Morocco and literature review.

    Science.gov (United States)

    Benatiya, Marwane Andaloussi; Rais, Ghizlane; Tahri, Mounir; Barki, Ali; El sayegh, Hachem; Iken, Ali; Nouini, Yassine; Lachkar, Azzouz; Benslimane, Lounis; Errihani, Hassan; Faik, Mohammed

    2012-01-01

    Renal oncocytoma is a rare and benign renal tumor. Only few cases have been reported in Moroccan populations. In the present study, we report our experiences in the diagnosis, management and follow-up of this disease. We report on six cases of renal oncocytoma indentified between 1990 and 2008 in the urology department of "CHU Ibn Sina" in Rabat. These six cases are listed among 130 kidney tumors reported during the study period. We assess the clinical, radiological and therapeutic features of the patients and we review literature. Six cases of renal oncocytoma, representing 4.6% of all primitive kidney tumors treated in our institution during the study period. The mean age was 53 ±9.7 years (range 34 to 61 years). One patient was asymptomatic at presentation, five patients (83%) had flank pain and two (33%) had macroscopic hematuria. The tumor was right sided in 4 cases (66%) and left sided in 2 cases (33%). All patients underwent CT scan which showed, in three cases, a centrally located stellate area of low attenuation. The clinical suspicion of oncocytoma was made preoperatively in only 3 patients by imaging studies, but the suspicion of renal cell carcinoma persist and all patients were treated with radical nephrectomy. Definitive diagnosis was made in all cases postoperatively. All the tumors were well circumscribed but unencapsulated. The mean tumor size was 8,75±2,04 cm. Four patients were classified at stage pT2 and two at stage p T1. Most of the pathological features in our patients were typical of this entity. Predominant cell type was a typical oncocytoma with general low mitotic activity. No extension to peri-nephric fat tissue or lymphovascular invasion was observed. After a mean follow-up of 36 months (range 26-62 months), there was neither recurrence nor death from oncocytoma. Accordingly, the disease-specific survival was 100%. Renal oncocytoma has a benign clinical course with excellent long-term outcomes. In our series, it happened mostly in

  16. A screening model for depleted uranium testing using environmental radiation monitoring data

    International Nuclear Information System (INIS)

    Dunfrund, F.L.; Ebinger, M.H.; Hansen, W.R.

    1996-01-01

    Information from an ecological risk assessment of depleted uranium test areas at Yuma Proving Ground (YPG) was used to update the required environmental radiation monitoring (ERM) plan. Data to be collected for the ERM can also be used to evaluate the potential for adverse radiological and toxicological effects to terrestrial reptiles and mammals in the affected areas. We developed a spreadsheet-based screening model that incorporates the ERM data and associated uncertainties. The purpose of the model is to provide a conservative estimate of radiological exposure of terrestrial, biota to DU using the ERM data. The uncertainty in the estimate is also predicted so that the variation in the radiological exposure can be used in assessing potential adverse effects from DU testing. Toxicological effects are evaluated as well as radiological effects in the same program using the same data. Our presentation shows an example data set, model calculations, and the report of expected radiation dose rates and probable kidney burdens of select mammals and reptiles. The model can also be used in an inverse mode to calculate the soil concentration required to give either a radiological dose that would produce a potential adverse effect such as fatal cancer or a toxicological dose that would result in nephrotoxic effects in mammals

  17. Recommendations for In Vitro and In Vivo Testing of Magnetic Nanoparticle Hyperthermia Combined with Radiation Therapy

    Directory of Open Access Journals (Sweden)

    Spiridon V. Spirou

    2018-05-01

    Full Text Available Magnetic nanoparticle (MNP-mediated hyperthermia (MH coupled with radiation therapy (RT is a novel approach that has the potential to overcome various practical difficulties encountered in cancer treatment. In this work, we present recommendations for the in vitro and in vivo testing and application of the two treatment techniques. These recommendations were developed by the members of Working Group 3 of COST Action TD 1402: Multifunctional Nanoparticles for Magnetic Hyperthermia and Indirect Radiation Therapy (“Radiomag”. The purpose of the recommendations is not to provide definitive answers and directions but, rather, to outline those tests and considerations that a researcher must address in order to perform in vitro and in vivo studies. The recommendations are divided into 5 parts: (a in vitro evaluation of MNPs; (b in vitro evaluation of MNP-cell interactions; (c in vivo evaluation of the MNPs; (d MH combined with RT; and (e pharmacokinetic studies of MNPs. Synthesis and characterization of the MNPs, as well as RT protocols, are beyond the scope of this work.

  18. Nuclear electronic equipment for control and monitoring panel. Specifications and methods for testing radiation detectors

    International Nuclear Information System (INIS)

    Roguin, Andre.

    1976-02-01

    This document will be of interest to users and makers of neutron and gamma radiations detectors in the field of nuclear reactor control and protection. Information is given which will enable users to optimize their choice and methods of using equipment, and makers to optimize their methods of fabrication. It should also serve as a model from which official specifications, technical instructions and test methods for these detectors, could be established. A detailed description is given of the appropriate parameters, terminology and notations. General specifications, operating conditions and test methods are indicated. The following detectors are studied: in-core detectors: fission ionization chambers, self powered neutron detectors (S.P.N.D.); out-core detectors: boron ionization chambers (for monitoring), boron trifluoride proportional counter tubes, boron lined proportional counter tubes, helium-3 proportional counter tubes. The devices described in the document are intended for industrial radiation monitoring applications and not for calibration standards (dosimetry) or for health physics measurement purposes. They are characterized by their fidelity, fast response, reliability and long lifetimes [fr

  19. In-beam test of a DIRC Cherenkov radiator with SiPM

    International Nuclear Information System (INIS)

    Kroeck, B.; Hayrapetyan, A.; Foehl, K.; Merle, O.; Dueren, M.; Roy, B.J.; Peters, K.

    2009-01-01

    One of the crucial points for any high energy physics experiment is to obtain a good pion/kaon separation i.e. particle identification (PID). For particles in minimum ionising range, the conventional methods of PID using energy loss and time of flight become insufficient. In such a situation, the measurement of velocity of particles using Cherenkov radiation is an effective tool for PID in combination with momentum information from a tracking detector. The PANDA experiment at FAIR/ GSI plans to use a novel technique for PID with detection of internally reflected Cherenkov (DIRC) light. DIRC uses, in contrast to the conventional gas Cherenkov detectors, a solid radiator and total internal reflection to guide Cherenkov photons onto a detection plane where it will be detected by advanced photon counters. A SiPM is a very new generation photon counter that has several advantages over conventional PMTs. Several prototype Cherenkov detectors with different readout systems are being developed for R and D studies. One such prototype detector with Geiger-APD readout has been built at Giessen and was tested in-beam at GSI. The present report provides details of the very first test measurement

  20. Offsite environmental monitoring report. Radiation monitoring around United States nuclear test areas, calendar year 1983

    International Nuclear Information System (INIS)

    Patzer, R.G.; Black, S.C.; Grossman, R.F.; Smith, D.D.

    1984-07-01

    This report covers the routine radiation monitoring activities conducted by the Environmental Monitoring Systems Laboratory-Las Vegas in areas which may be affected by nuclear testing programs of the Department of Energy. This monitoring is conducted to document compliance with standards, to identify trends in environmental radiation, and to provide such information to the public. It summarizes these activities for calendar year 1983. No radioactivity attributable to NTS activities was detectable offsite by the monitoring networks. Using recorded wind data and Pasquill stability categories, atmospheric dispersion calculations based on reported radionuclide releases yield an estimated dose of 5 x 10 -5 man-rem to the population within 80 km of the Nevada Test Site during 1983. World-wide fallout of Kr-85, Sr-90, Cs-137, and Pu-239 detected by the monitoring networks would cause maximum exposure to an individual of less than 0.2 mrem per year. Plutonium and krypton in air were similar to 1982 levels while cesium and strontium in other samples were near the detection limits. An occasional net exposure to offsite residents has been detected by the TLD network. On investigation, the cause of such net exposures has been due to personal habits or occupational activities, not to NTS activities. 29 references, 35 figures, 30 tables

  1. Epidemiological and immunological studies of radiation accidents and nucleare tests participants

    International Nuclear Information System (INIS)

    Shubik, V. M.; Bronstein, I. E.; Koroleva, T.M.; Strelnicova, T.M.; Sukalskay, S. J.

    2004-01-01

    Results of long term studies of epidemiological and immunological problems after radiation accidents in Ural. At Chernobyl and nuclear weapons tests in Semi-palatinsk and Novaya Zemlya nuclear tests sites are presented. Changes in Health and immunity status of emergency team workers (liquida-tors) and participants on nuclear weapon tests were recorded in long term studies af-ter 10 and more years after radiation exposure. Some changes (decrease in ly-sozyme activity, disimmunoglobulinemia) could be attributed to the old age of exam-ined persons and concomitant cardiovasculatory, respiratory and other diseases An-other ones were related to the autoimmune syndromes. Humoral and cellular auto-immune changes were more pronounced in liquidators and participants then in controls. concentrations of antitissue antibodies in exposed cohort was three times higher than in control. Level of antibodies to thyroid antigens (microsoms and thy-roglobulines) were five times higher in liquidators of Chernobyl accident. The pos-sible role of humoral and cell autoimmune changes in the development of cardiovascular, liver, kidney and thyroid is considered. Considerable increase in some cytocine concentrations in blood of participants was found. For example increased concentration of TNF was recorded in half of par-ticipants from Novaya Zemlya in comparison to similar changes in only twenty pro-cents of controls. In half of participants from Semipalatinsk site the virus antigens in epithelium of higher respiratory tract (mostly adenoviruses) were found, with 22% in control group. In health and immunity studies of population from the contaminated areas after accidents and nuclear tests (Ural, Bryansk, Russian arktics) the demographics changes, mortality structure changes, oncological mortality and immunological deficiencies were found. The recorded effects might by considered as a results of combined effect of ra-diological and non-radiological factors. The potentiated effect of chronic

  2. The HAW-Project: Test disposal of highly radioactive radiation sources in the Asse salt mine

    International Nuclear Information System (INIS)

    1992-04-01

    Two electrical heater tests were already started in November 1988 and are continuously surveyed in respect of the thermomechanical and geochemical response of the rock mass. Also the handling system necessary for the emplacement of 30 radioactive canisters (Sr-90 and Cs-137 sources) was developed and succesfully tested. This system consists of six multiple transport and storage casks of the type Castor-GSF-5, two above ground/below ground shuttle transport casks of the type Asse TB1, an above ground transfer station, an underground transport vehicle, a disposal machine, and a borehole slider. A laboratory investigation program on radiation effects in salt is being performed in advance to the radioactive canister emplacement. This program includes the investigation of thermally and radiolytically induced water and gas release from the rock salt and the radiolytical decomposition of salt minerals. For gamma dose and dose rate measurements in the test field measuring systems consisting of ionisation chambers as well as solid state dosemeters were developed and tested. Thermomechanical computer code validation is performed by calculational predictions and parallel investigation of the stress and displacement fields in the underground test field. (orig./HP)

  3. The script concordance test in radiation oncology: validation study of a new tool to assess clinical reasoning

    International Nuclear Information System (INIS)

    Lambert, Carole; Gagnon, Robert; Nguyen, David; Charlin, Bernard

    2009-01-01

    The Script Concordance test (SCT) is a reliable and valid tool to evaluate clinical reasoning in complex situations where experts' opinions may be divided. Scores reflect the degree of concordance between the performance of examinees and that of a reference panel of experienced physicians. The purpose of this study is to demonstrate SCT's usefulness in radiation oncology. A 90 items radiation oncology SCT was administered to 155 participants. Three levels of experience were tested: medical students (n = 70), radiation oncology residents (n = 38) and radiation oncologists (n = 47). Statistical tests were performed to assess reliability and to document validity. After item optimization, the test comprised 30 cases and 70 questions. Cronbach alpha was 0.90. Mean scores were 51.62 (± 8.19) for students, 71.20 (± 9.45) for residents and 76.67 (± 6.14) for radiation oncologists. The difference between the three groups was statistically significant when compared by the Kruskall-Wallis test (p < 0.001). The SCT is reliable and useful to discriminate among participants according to their level of experience in radiation oncology. It appears as a useful tool to document the progression of reasoning during residency training

  4. Procedure to carry out leakage test in beta radiation sealed sources emitters of 90Sr/90Y

    International Nuclear Information System (INIS)

    Alvarez R, J. T.

    2010-09-01

    In the alpha-beta room of the Secondary Laboratory of Dosimetric Calibration of the Metrology Department of Ionizing Radiations ophthalmic applicators are calibrated in absorbed dose terms in water D w ; these applicators, basically are emitter sealed sources of pure beta radiation of 90 Sr / 90 Y. Concretely, the laboratory quality system indicates to use the established procedure for the calibration of these sources, which establishes the requirement of to carry out a leakage test, before to calibrate the source. However, in the Laboratory leakage test certificates sent by specialized companies in radiological protection services have been received, in which are used gamma spectrometry equipment s for beta radiation leakage tests, since it is not reliable to detect pure beta radiation with a scintillating detector with NaI crystal, (because it could detect the braking radiation produced in the detector). Therefore the Laboratory has had to verify the results of the tests with a correct technique, with the purpose of determining the presence of sources with their altered integrity and radioactive material leakage. The objective of this work is to describe a technique for beta activity measurement - of the standard ISO 7503, part 1 (1988) - and its application with a detector Gm plane (type pankage) in the realization of leakage tests in emitter sources of pure beta radiation, inside the mark of quality assurance indicated by the report ICRU 76. (Author)

  5. Test models for estimating radiation balance in different scales for Jaboticabal, SP

    Directory of Open Access Journals (Sweden)

    Valquíria de Alencar Beserra

    2012-12-01

    Full Text Available The net radiation (Rn in agroecosystems is the amount of energy that is available in the environment to heating processes of living organisms, air and soil; perspiration of animals and plants; photosynthesis and water evaporation. The Rn defines the type of climate and weather conditions prevailing in a region affecting the availability and thermal water, the fundamental understanding of genotype-environment, which ultimately determine the productivity of the agricultural system. Rn usually is used in models of weather and climate studies. The sustainability and economic viability of zootechnical activity is dependent on the positive interaction between animal and environment. Environmental factors such as water, shading, thermal exchanges sensible heat (conduction, convection and radiation skin and latent heat losses (evaporation and transpiration, conditioned by Rn, must be managed to provide the best results. The present study was conducted to develop and test models for accurate and precise radiation balance on the scales daily, monthly and seasonal ten-day for Jaboticabal - SP, due to the importance of estimates of net radiation for agricultural activities. We used daily meteorological data from weather station located in Jaboticabal, SP (coordinates: 21 ° 14'05 "South, 48 ° 17'09" West, 615m altitude at Universidade Estadual Paulista "Júlio Mesquita Filho" - FCAV/UNESP in a situation of default grass "Bahiagrass" during the period 20/08/2005 to 20/01/2012. The data used were the maximum temperature (Tmax, minimum (Tmin and mean (TMED; maximum relative humidity (URMáx, minimum (URMín and average (URMéd precipitation (mm, average velocity (m/s, Qo, solar radiation (MJ m-2, sunshine (hour meter (MJ m², soil temperature at two depths (Tsoil2CM, Tsoil5CM and class A pan evaporation (TCA (mm. The measures taken by the balance radiometer were taken as a reference to test other models. The models tested were those reported by NORMAN et al

  6. Latch-up and radiation integrated circuit--LURIC: a test chip for CMOS latch-up investigation

    International Nuclear Information System (INIS)

    Estreich, D.B.

    1978-11-01

    A CMOS integrated circuit test chip (Latch-Up and Radiation Integrated Circuit--LURIC) designed for CMOS latch-up and radiation effects research is described. The purpose of LURIC is (a) to provide information on the physics of CMOS latch-up, (b) to study the layout dependence of CMOS latch-up, and (c) to provide special latch-up test structures for the development and verification of a latch-up model. Many devices and test patterns on LURIC are also well suited for radiation effects studies. LURIC contains 86 devices and related test structures. A 12-layer mask set allows both metal gate CMOS and silicon gate ELA (Extended Linear Array) CMOS to be fabricated. Six categories of test devices and related test structures are included. These are (a) the CD4007 metal gate CMOS IC with auxiliary test structures, (b) ELA CMOS cells, (c) field-aided lateral pnp transistors, (d) p-well and substrate spreading resistance test structures, (e) latch-up test structures (simplified symmetrical latch-up paths), and (f) support test patterns (e.g., MOS capacitors, p + n diodes, MOS test transistors, van der Pauw and Kelvin contact resistance test patterns, etc.). A standard probe pattern array has been used on all twenty-four subchips for testing convenience

  7. The DNA comet assay and the germination test in detection of food treated by ionizing radiation

    International Nuclear Information System (INIS)

    Huachaca, Nelida Simona Marin

    2002-01-01

    Two methods of irradiated food detection, one biochemical, the comet assay and, other biological, the germination test, were applied in bovine meat and fruit samples. The comet assay detects the damage on DNA caused by ionizing radiation. The germination test evaluates the sensitivity to radiation of seeds as for germination ability, shooting and, rooting. The samples were irradiated in gamma font and electron accelerator. For bovine meat samples, the doses were 0.0; 2.5; 4.5 e 7.0 kGy at chilled condition and, 0.0; 2.5; 4.5; 7.0 e 8.5 kGy at frozen conditions. For fruit samples such as melon, watermelon, apple, orange, papaya and, tomato, the doses were: 0.0; 0.5; 0.75; 1.0; 2.0 e 4.0 kGy. The differences between the gamma rays and the electron beam effects on extent of DNA migration and, on shooting and rooting, showed to be similar. The comet assay, under neutral conditions, permitted to discriminate between irradiated and unirradiated bovine meat samples, until one month of storage. Also, it was possible to distinguish, by the comet assay, the control sample with regard to irradiated fruit, at doses as low as 0,5 kGy. In the germination test, the root length was the best parameter to discriminate irradiated and unirradiated samples of melon, watermelon and tomato, while the germination percent was the best parameter for apple and orange. (author)

  8. The morphological changes of adult mouse testes after 60Co Gamma-radiation

    International Nuclear Information System (INIS)

    Koruji, M.; Movahedin, M.; Gourabi, H.; Jabbary Arfaee, A.

    2008-01-01

    Cytotoxic therapy can lead to prolonged azoospermia or even sterility. In the present study, we investigated the morphological changes of mouse testes after γ-Radiation. Methods: After anesthetizing of NMRI mice, testes and their surrounding tissues were irradiated using a cobalt therapy machine. Four experimental groups were irradiated with fractionated doses of: 1.5+8, 1.5+12 and 1.5+16 Gy (with an interval of 24 h) and single dose of 14 Gy. Non-irradiated mice were considered as control group. Testes were removed 4, 6 and 8 weeks following irradiation, weighed and processed for light microscopic study. Diameters of seminiferous tubules and their lumens, epithelium thickness, percentage of different types of tubules and number of spermatogenic cell were measured. Moreover, sperm count motility and viability rates were evaluated in epididymis. Results: Number of normal tubules, epithelium thickness, tubules diameter and lumen diameter were significantly reduced with high dose irradiation in comparison with control testes. The recovery was observed after 8 weeks. Epididymal sperm count, motility and viability rates were significantly decreased in the irradiated mice comparing non-irradiated ones. These parameters were increased after 8 weeks. Conclusion: According to the results, irradiation can cause temporary azoospermia in mouse and this effect is reversible after 8 weeks

  9. Hypothesis tests for the detection of constant speed radiation moving sources

    Energy Technology Data Exchange (ETDEWEB)

    Dumazert, Jonathan; Coulon, Romain; Kondrasovs, Vladimir; Boudergui, Karim; Sannie, Guillaume; Gameiro, Jordan; Normand, Stephane [CEA, LIST, Laboratoire Capteurs Architectures Electroniques, 99 Gif-sur-Yvette, (France); Mechin, Laurence [CNRS, UCBN, Groupe de Recherche en Informatique, Image, Automatique et Instrumentation de Caen, 4050 Caen, (France)

    2015-07-01

    Radiation Portal Monitors are deployed in linear network to detect radiological material in motion. As a complement to single and multichannel detection algorithms, inefficient under too low signal to noise ratios, temporal correlation algorithms have been introduced. Test hypothesis methods based on empirically estimated mean and variance of the signals delivered by the different channels have shown significant gain in terms of a tradeoff between detection sensitivity and false alarm probability. This paper discloses the concept of a new hypothesis test for temporal correlation detection methods, taking advantage of the Poisson nature of the registered counting signals, and establishes a benchmark between this test and its empirical counterpart. The simulation study validates that in the four relevant configurations of a pedestrian source carrier under respectively high and low count rate radioactive background, and a vehicle source carrier under the same respectively high and low count rate radioactive background, the newly introduced hypothesis test ensures a significantly improved compromise between sensitivity and false alarm, while guaranteeing the stability of its optimization parameter regardless of signal to noise ratio variations between 2 to 0.8. (authors)

  10. Radiation effects on testes. XI. Studies on glycogen and its metabolizing enzymes following radiation-induced atrophy

    International Nuclear Information System (INIS)

    Gupta, G.S.; Bawa, S.R.

    1977-01-01

    Effect of radiation on enzymes of carbohydrate metabolism has been studied. It is observed that hexokinase of testis is highly sensitive to radiation damage. Reduced hexokinase activity seems to be related to those parts of the testis (spermatocytes and spermatids) which depend upon glucose for their functioning. Radiation-induced atrophic testis is rich in glycogen content. The observations on the inhibition of gluocose-6-phosphatase and phosphorylase may explain the higher levels of the polysaccharide although a possibility of enhanced glycogenesis due to the activation of glycogen synthetase has also been suggested. The presence of glucose-6-phosphate isomerase and glycogen in atrophied testis in 11-month-treated rats indicate the higher glycolytic activity with hyperplastic testicular interstitium. The results suggest that the accumulated glycogen is acting as a reserve substrate in nongerminal cells

  11. Preliminary assays for lemongrass essential oil ecotoxicological test in D. similis and C. silvestrii submitted to gamma radiation

    International Nuclear Information System (INIS)

    Gimiliani, Giovana T.; Rogero, Sizue O.; Rogero, Jose R.; Cruz, Aurea S.

    2011-01-01

    Pharmaceutical products are of great interest in ecotoxicological studies due to being found some of these products in the superficial waters and sediments, water and sewage treatment effluents. It was verified an increase of insect repellent chemical products in the aquatic environment because of the increase of diseases transmitted by mosquitoes like dengue. As these compounds show toxicity, the use of essential oils natural products with repellent properties is increasing and the literature about the impact in the aquatic environment is scarce. The hydric frame would suffer natural radiation and radiations from energy generation nuclear plants impacts fall out of tests and nuclear accidents. There is no universal definition of environmental protection and there are few studies on radiation effects in the aquatic environment. In this study was determined the lemon grass essential oil toxicity level as well as the lethal dose of ionizing radiation, LD 50 , in aquatic organisms. Cytotoxicity test was performed by in vitro neutral red uptake method in NCTC clone L929 cell line. In the LD 50 test aquatic organisms were submitted to gamma radiation. The essential oil of lemongrass Cymbopogon flexuosus showed cytotoxicity index IC 50 about 50μg.mL -1 . The LD 50 for Daphnia similis was 242 Gy and Ceriodaphnia silvestrii about 525 Gy. Studies will be continued with acute and chronic ecotoxicological tests of lemongrass essential oil in natural organisms and in organisms submitted to gamma radiation, utilizing the results obtained in this work. (author)

  12. Preliminary assays for lemongrass essential oil ecotoxicological test in D. similis and C. silvestrii submitted to gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Gimiliani, Giovana T.; Rogero, Sizue O.; Rogero, Jose R., E-mail: gtgimiliani@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Cruz, Aurea S. [Instituto Adolfo Lutz, Sao Paulo, SP (Brazil). Culturas Celulares

    2011-07-01

    Pharmaceutical products are of great interest in ecotoxicological studies due to being found some of these products in the superficial waters and sediments, water and sewage treatment effluents. It was verified an increase of insect repellent chemical products in the aquatic environment because of the increase of diseases transmitted by mosquitoes like dengue. As these compounds show toxicity, the use of essential oils natural products with repellent properties is increasing and the literature about the impact in the aquatic environment is scarce. The hydric frame would suffer natural radiation and radiations from energy generation nuclear plants impacts fall out of tests and nuclear accidents. There is no universal definition of environmental protection and there are few studies on radiation effects in the aquatic environment. In this study was determined the lemon grass essential oil toxicity level as well as the lethal dose of ionizing radiation, LD{sub 50}, in aquatic organisms. Cytotoxicity test was performed by in vitro neutral red uptake method in NCTC clone L929 cell line. In the LD{sub 50} test aquatic organisms were submitted to gamma radiation. The essential oil of lemongrass Cymbopogon flexuosus showed cytotoxicity index IC{sub 50} about 50{mu}g.mL{sup -1}. The LD{sub 50} for Daphnia similis was 242 Gy and Ceriodaphnia silvestrii about 525 Gy. Studies will be continued with acute and chronic ecotoxicological tests of lemongrass essential oil in natural organisms and in organisms submitted to gamma radiation, utilizing the results obtained in this work. (author)

  13. Characteristics of X ray calibration fields for performance test of radiation measuring instruments

    International Nuclear Information System (INIS)

    Shimizu, Shigeru; Takahashi, Fumiaki; Sawahata, Tadahiro; Tohnami, Kohichi; Kikuchi, Hiroshi; Murayama, Takashi

    1999-02-01

    Performance test and calibration of the radiation measuring instruments for low energy photons are made using the X ray calibration fields which are monochromatically characterized by filtration of continuous X ray spectrum. The X ray calibration field needs to be characterized by some quality conditions such as quality index and homogeneity coefficient. The present report describes quality conditions, spectrum and some characteristics of X ray irradiation fields in the Facility of Radiation Standard of the Japan Atomic Energy Research Institute (FRS-JAERI). Fifty nine X ray qualities with the quality index of 0.6, 0.7, 0.8 and 0.9 were set for the tube voltages between 10 kV and 350 kV. Estimation of X ray spectrum measured with a Ge detector was made in terms of exposure, ambient dose equivalent and fluence for all the obtained qualities. Practical irradiation field was determined as the dose distribution uniformity is within ±3%. The obtained results improve the quality of X ray calibration fields and calibration accuracy. (author)

  14. First tests of a novel radiation hard CMOS sensor process for Depleted Monolithic Active Pixel Sensors

    Science.gov (United States)

    Pernegger, H.; Bates, R.; Buttar, C.; Dalla, M.; van Hoorne, J. W.; Kugathasan, T.; Maneuski, D.; Musa, L.; Riedler, P.; Riegel, C.; Sbarra, C.; Schaefer, D.; Schioppa, E. J.; Snoeys, W.

    2017-06-01

    The upgrade of the ATLAS [1] tracking detector for the High-Luminosity Large Hadron Collider (LHC) at CERN requires novel radiation hard silicon sensor technologies. Significant effort has been put into the development of monolithic CMOS sensors but it has been a challenge to combine a low capacitance of the sensing node with full depletion of the sensitive layer. Low capacitance brings low analog power. Depletion of the sensitive layer causes the signal charge to be collected by drift sufficiently fast to separate hits from consecutive bunch crossings (25 ns at the LHC) and to avoid losing the charge by trapping. This paper focuses on the characterization of charge collection properties and detection efficiency of prototype sensors originally designed in the framework of the ALICE Inner Tracking System (ITS) upgrade [2]. The prototypes are fabricated both in the standard TowerJazz 180nm CMOS imager process [3] and in an innovative modification of this process developed in collaboration with the foundry, aimed to fully deplete the sensitive epitaxial layer and enhance the tolerance to non-ionizing energy loss. Sensors fabricated in standard and modified process variants were characterized using radioactive sources, focused X-ray beam and test beams before and after irradiation. Contrary to sensors manufactured in the standard process, sensors from the modified process remain fully functional even after a dose of 1015neq/cm2, which is the the expected NIEL radiation fluence for the outer pixel layers in the future ATLAS Inner Tracker (ITk) [4].

  15. Beam test results of CMS RPCs at high eta region under high-radiation environment

    CERN Document Server

    Park, S; Bahk, S Y; Hong, B; Hong, S J; Kang, D H; Kang, T I; Kim, T J; Kim, Y J; Kim, Y U; Koo, D G; Lee, H W; Lee, K S; Lee, S J; Lim, J K; Moon, D H; Nam, S K; Oh, J K; Park, W J; Rhee, J T; Ryu, M S; Shim, H H; Sim, K S

    2004-01-01

    The Compact Muon Solenoid (CMS) forward resistivity plate chambers (RPCs) at the high eta region must be operated in presence of a radiation-induced rate as high as 1 kHz/cm**2. It is still unknown if the RPCs coated with linseed oil can be operated under such a high- radiation environment over the lifetime of CMS. Non-oiled RPCs may be one of the options since phenolic or melamine-coated bakelite is chemically stabler than linseed oil. We have constructed oiled and non-oiled RPCs at the high eta region of CMS using phenolic bakelite and tested them in the Gamma Irradiation Facility at CERN. While both RPCs show the same characteristics in the efficiency and the strip multiplicity, the non-oiled RPC generates an intrinsic noise rate of 50 Hz/cm**2, compared to only 5 Hz/cm**2 for the oiled RPC, both at 10.0kV which is about 100 V above the 95% knee of the efficiency curve.

  16. Test of the linear-no threshold theory of radiation carcinogenesis

    International Nuclear Information System (INIS)

    Cohen, B.L.

    1998-01-01

    It is shown that testing the linear-no threshold theory (L-NT) of radiation carcinogenesis is extremely important and that lung cancer resulting from exposure to radon in homes is the best tool for doing this. A study of lung cancer rates vs radon exposure in U.S. Counties, reported in 1975, is reviewed. It shows, with extremely powerful statistics, that lung cancer rates decrease with increasing radon exposure, in sharp contrast to the prediction of L-NT, with a discrepancy of over 20 standard deviations. Very extensive efforts were made to explain an appreciable part of this discrepancy consistently with L-NT, with no success; it was concluded that L-NT fails, grossly exaggerating the cancer risk of low level radiation. Two updating studies reported in 1996 are also reviewed. New updating studies utilizing more recent lung cancer statistics and considering 450 new potential confounding factors are reported. All updates reinforce the previous conclusion, and the discrepancy with L-NT is increased. (author)

  17. Beam test results of CMS RPCs at high eta region under high-radiation environment

    International Nuclear Information System (INIS)

    Park, S.; Ahn, S.H.; Bahk, S.Y.; Hong, B.; Hong, S.J.; Kang, D.H.; Kang, T.I.; Kim, T.J.; Kim, Y.J.; Kim, Y.U.; Koo, D.G.; Lee, H.W.; Lee, K.S.; Lee, S.J.; Lim, J.K.; Moon, D.H.; Nam, S.K.; Oh, J.K.; Park, W.J.; Rhee, J.T.; Ryu, M.S.; Shim, H.H.; Sim, K.S.

    2004-01-01

    The Compact Muon Solenoid (CMS) forward resistivity plate chambers (RPCs) at the high eta region must be operated in presence of a radiation-induced rate as high as 1kHz/cm2. It is still unknown if the RPCs coated with linseed oil can be operated under such a high-radiation environment over the lifetime of CMS. Non-oiled RPCs may be one of the options since phenolic or melamine-coated bakelite is chemically stabler than linseed oil. We have constructed oiled and non-oiled RPCs at the high eta region of CMS using phenolic bakelite and tested them in the Gamma Irradiation Facility at CERN. While both RPCs show the same characteristics in the efficiency and the strip multiplicity, the non-oiled RPC generates an intrinsic noise rate of 50Hz/cm2, compared to only 5Hz/cm2 for the oiled RPC, both at 10.0kV which is about 100V above the 95% knee of the efficiency curve

  18. Radiation Hardness tests with neutron flux on different Silicon photomultiplier devices

    Science.gov (United States)

    Cattaneo, P. W.; Cervi, T.; Menegolli, A.; Oddone, M.; Prata, M.; Prata, M. C.; Rossella, M.

    2017-07-01

    Radiation hardness is an important requirement for solid state readout devices operating in high radiation environments common in particle physics experiments. The MEG II experiment, at PSI, Switzerland, investigates the forbidden decay μ+ → e+ γ. Exploiting the most intense muon beam of the world. A significant flux of non-thermal neutrons (kinetic energy Ek>= 0.5 MeV) is present in the experimental hall produced along the beam-line and in the hall itself. We present the effects of neutron fluxes comparable to the MEG II expected doses on several Silicon Photomultiplier (SiPMs). The tested models are: AdvanSiD ASD-NUV3S-P50 (used in MEG II experiment), AdvanSiD ASD-NUV3S-P40, AdvanSiD ASD-RGB3S-P40, Hamamatsu and Excelitas C30742-33-050-X. The neutron source is the thermal Sub-critical Multiplication complex (SM1) moderated with water, located at the University of Pavia (Italy). We report the change of SiPMs most important electric parameters: dark current, dark pulse frequency, gain, direct bias resistance, as a function of the integrated neutron fluency.

  19. Mercury Conditions for the MESSENGER Mission Simulated in High- Solar-Radiation Vacuum Tests

    Science.gov (United States)

    Wong, Wayne A.

    2003-01-01

    The MESSENGER (Mercury Surface, Space Environment, Geochemistry, and Ranging) spacecraft, planned for launch in March 2004, will perform two flybys of Mercury before entering a year-long orbit of the planet in September 2009. The mission will provide opportunities for detailed characterization of the surface, interior, atmosphere, and magnetosphere of the closest planet to the Sun. The NASA Glenn Research Center and the MESSENGER spacecraft integrator, the Johns Hopkins University Applied Physics Laboratory, have partnered under a Space Act Agreement to characterize a variety of critical components and materials under simulated conditions expected near Mercury. Glenn's Vacuum Facility 6, which is equipped with a solar simulator, can simulate the vacuum and high solar radiation anticipated in Mercury orbit. The MESSENGER test hardware includes a variety of materials and components that are being characterized during the Tank 6 vacuum tests, where the hardware will be exposed to up to 11 suns insolation, simulating conditions expected in Mercury orbit. In 2002, ten solar vacuum tests were conducted, including beginning of life, end of life, backside exposure, and solar panel thermal shock cycling tests. Components tested include candidate solar array panels, sensors, thermal shielding materials, and communication devices. As an example, for the solar panel thermal shock cycling test, two candidate solar array panels were suspended on a lift mechanism that lowered the panels into a liquid-nitrogen-cooled box. After reaching -140 C, the panels were then lifted out of the box and exposed to the equivalent of 6 suns (8.1 kilowatts per square meters). After five cold soak/heating cycles were completed successfully, there was no apparent degradation in panel performance. An anticipated 100-hr thermal shield life test is planned for autumn, followed by solar panel flight qualification tests in winter. Glenn's ongoing support to the MESSENGER program has been instrumental in

  20. Testing of the effect of the entry beam tube windows of the silicon detectors of the ionisation radiation

    International Nuclear Information System (INIS)

    Kopestansky, J.; Tykva, R.; Stanek, S.

    1995-01-01

    This paper deals with testing of the entry beam tube windows of the silicon detectors of the ionisation radiation with surface barrier.The influence of the parameters of basic material and modified technologic preparation on the size and homogeneity of the windows was tested

  1. Compilation of radiation damage test data. Pt. 2. Thermoset and thermoplastic resins, composite materials

    International Nuclear Information System (INIS)

    Tavlet, M.; Fontaine, A.; Schoenbacher, H.

    1998-01-01

    This catalogue summarizes radiation damage test data on thermoplastic and thermoset resins and composites. Most of them are epoxy resins used as insulator for magnet coils. Many results are also given for new engineering thermoplastics which can be used either for their electrical properties or for their mechanical properties. The materials have been irradiated either in a 60 Co source, up to integrated absorbed doses between 200 kGy and a few megagrays, at dose rates of the order of 1 Gy/s, or in a nuclear reactor at dose rates of the order of 50 Gy/s, up to doses of 100 MGy. The flexural strength, the deformation and the modulus of elasticity have been measured on irradiated and non-irradiated samples, according to the recommendations of the International Electrotechnical Commissions. The results are presented in the form of tables and graphs to show the effect of the absorbed dose on the measured properties. (orig.)

  2. Compilation of radiation damage test data. Pt. 2. Thermoset and thermoplastic resins, composite materials

    Energy Technology Data Exchange (ETDEWEB)

    Tavlet, M; Fontaine, A; Schoenbacher, H

    1998-05-18

    This catalogue summarizes radiation damage test data on thermoplastic and thermoset resins and composites. Most of them are epoxy resins used as insulator for magnet coils. Many results are also given for new engineering thermoplastics which can be used either for their electrical properties or for their mechanical properties. The materials have been irradiated either in a {sup 60}Co source, up to integrated absorbed doses between 200 kGy and a few megagrays, at dose rates of the order of 1 Gy/s, or in a nuclear reactor at dose rates of the order of 50 Gy/s, up to doses of 100 MGy. The flexural strength, the deformation and the modulus of elasticity have been measured on irradiated and non-irradiated samples, according to the recommendations of the International Electrotechnical Commissions. The results are presented in the form of tables and graphs to show the effect of the absorbed dose on the measured properties. (orig.)

  3. Radiation hardness tests of double-sided 3D strip sensors with passing-through columns

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Betta, Gian-Franco, E-mail: gianfranco.dallabetta@unitn.it [Dipartimento di Ingegneria Industriale, Università degli Studi di Trento, Via Sommarive 9, I-38123 Trento (Italy); INFN TIFPA, Via Sommarive 14, I-38123 Trento (Italy); Betancourt, Christopher [Institute of Physics, University of Freiburg, Hermann-Herder-Str. 3, 79104 Freiburg (Germany); Boscardin, Maurizio; Giacomini, Gabriele [Fondazione Bruno Kessler, Centro per i Materiali e i Microsistemi (FBK-CMM), Via Sommarive 18, I-38123 Trento (Italy); Jakobs, Karl; Kühn, Susanne [Institute of Physics, University of Freiburg, Hermann-Herder-Str. 3, 79104 Freiburg (Germany); Lecini, Besnik [Dipartimento di Ingegneria Industriale, Università degli Studi di Trento, Via Sommarive 9, I-38123 Trento (Italy); Mendicino, Roberto [Dipartimento di Ingegneria Industriale, Università degli Studi di Trento, Via Sommarive 9, I-38123 Trento (Italy); INFN TIFPA, Via Sommarive 14, I-38123 Trento (Italy); Mori, Riccardo; Parzefall, Ulrich [Institute of Physics, University of Freiburg, Hermann-Herder-Str. 3, 79104 Freiburg (Germany); Povoli, Marco [Dipartimento di Ingegneria Industriale, Università degli Studi di Trento, Via Sommarive 9, I-38123 Trento (Italy); Thomas, Maira [Institute of Physics, University of Freiburg, Hermann-Herder-Str. 3, 79104 Freiburg (Germany); Zorzi, Nicola [Fondazione Bruno Kessler, Centro per i Materiali e i Microsistemi (FBK-CMM), Via Sommarive 18, I-38123 Trento (Italy)

    2014-11-21

    This paper deals with a radiation hardness study performed on double-sided 3D strip sensors with passing-through columns. Selected results from the characterization of the irradiated sensors with a beta source and a laser setup are reported and compared to pre-irradiation results and to TCAD simulations. The sensor performance in terms of signal efficiency is found to be in good agreement with that of other 3D sensors irradiated at the same fluences and tested under similar experimental conditions. - Highlights: • We report results from 3D silicon strip detectors irradiated up to HL-LHC fluences. • I–V curves, noise, charge collection measurements and laser scans are shown. • In all sensors, signals are distinguished from the noise already at low voltage. • Signal efficiency is in agreement with values expected from the electrode geometry. • Efficiency and spatial uniformity would benefit from higher operation voltages.

  4. Radiation hardness tests with a demonstrator preamplifier circuit manufactured in silicon on sapphire (SOS) VLSI technology

    International Nuclear Information System (INIS)

    Bingefors, N.; Ekeloef, T.; Eriksson, C.; Paulsson, M.; Moerk, G.; Sjoelund, A.

    1992-01-01

    Samples of the preamplifier circuit, as well as of separate n and p channel transistors of the type contained in the circuit, were irradiated with gammas from a 60 Co source up to an integrated dose of 3 Mrad (30 kGy). The VLSI manufacturing technology used is the SOS4 process of ABB Hafo. A first analysis of the tests shows that the performance of the amplifier remains practically unaffected by the radiation for total doses up to 1 Mrad. At higher doses up to 3 Mrad the circuit amplification factor decreases by a factor between 4 and 5 whereas the output noise level remains unchanged. It is argued that it may be possible to reduce the decrease in amplification factor in future by optimizing the amplifier circuit design further. (orig.)

  5. Radiation hardness tests of double-sided 3D strip sensors with passing-through columns

    International Nuclear Information System (INIS)

    Dalla Betta, Gian-Franco; Betancourt, Christopher; Boscardin, Maurizio; Giacomini, Gabriele; Jakobs, Karl; Kühn, Susanne; Lecini, Besnik; Mendicino, Roberto; Mori, Riccardo; Parzefall, Ulrich; Povoli, Marco; Thomas, Maira; Zorzi, Nicola

    2014-01-01

    This paper deals with a radiation hardness study performed on double-sided 3D strip sensors with passing-through columns. Selected results from the characterization of the irradiated sensors with a beta source and a laser setup are reported and compared to pre-irradiation results and to TCAD simulations. The sensor performance in terms of signal efficiency is found to be in good agreement with that of other 3D sensors irradiated at the same fluences and tested under similar experimental conditions. - Highlights: • We report results from 3D silicon strip detectors irradiated up to HL-LHC fluences. • I–V curves, noise, charge collection measurements and laser scans are shown. • In all sensors, signals are distinguished from the noise already at low voltage. • Signal efficiency is in agreement with values expected from the electrode geometry. • Efficiency and spatial uniformity would benefit from higher operation voltages

  6. Error-Rate Estimation Based on Multi-Signal Flow Graph Model and Accelerated Radiation Tests.

    Directory of Open Access Journals (Sweden)

    Wei He

    Full Text Available A method of evaluating the single-event effect soft-error vulnerability of space instruments before launched has been an active research topic in recent years. In this paper, a multi-signal flow graph model is introduced to analyze the fault diagnosis and meantime to failure (MTTF for space instruments. A model for the system functional error rate (SFER is proposed. In addition, an experimental method and accelerated radiation testing system for a signal processing platform based on the field programmable gate array (FPGA is presented. Based on experimental results of different ions (O, Si, Cl, Ti under the HI-13 Tandem Accelerator, the SFER of the signal processing platform is approximately 10-3(error/particle/cm2, while the MTTF is approximately 110.7 h.

  7. Ageing tests of radiation damaged lasers and photodiodes for the CMS experiment at CERN

    CERN Document Server

    Gill, K; Batten, J; Cervelli, G; Grabit, R; Jensen, F; Troska, Jan K; Vasey, F

    2000-01-01

    The effects of thermally accelerated ageing in irradiated and unirradiated 1310 nm InGaAsP edge-emitting lasers and InGaAs p-i-n photodiodes are presented. 40 lasers (20 irradiated) and 30 photodiodes (19 irradiated) were aged for 4000 hours at 80 degrees C. Periodic measurements were made of laser threshold and efficiency, and p-i-n leakage current and photocurrent. There were no sudden failures and there was very little wearout related degradation in either unirradiated or irradiated sample groups. The results suggest that the tested devices have a sufficiently long lifetime to operate for at least 10 years inside the Compact Muon Solenoid experiment despite being exposed to a harsh radiation environment. (19 refs).

  8. Radiation safety aspects during nondestructive testing of reactor shielding components by gamma radiometry

    International Nuclear Information System (INIS)

    Viswanathan, S.; Jose, M.T.; Venkatraman, B.

    2016-01-01

    In nuclear facilities, effective shielding of radioactive components and structures are essential to ensure radiation protection to operating personnel. The shield structures are made of lead, steel and concrete with varying thickness of up to 1200 mm. It needs to be verified for shielding integrity, presence of voids, blowholes and defects to avoid exposure to workers and to public at large. Radiometry using gamma source serves as excellent tool for non-destructive examination of such structures and components. Gamma sources of high activity up to 50 Curies (gamma camera type) depending on the thickness of component have to be used. During the testing exposure to the operating personnel needs to be minimized, this requires certain safety procedures to be followed. This paper focuses the methodology to be adapted by means of selection of source, effective training of personnel, compliance with safety requirements and maintenance of source devices

  9. Statistical properties of SASE FEL radiation: experimental results from the VUV FEL at the TESLA test facility at DESY

    International Nuclear Information System (INIS)

    Yurkov, M.V.

    2002-01-01

    This paper presents an experimental study of the statistical properties of the radiation from a SASE FEL. The experiments were performed at the TESLA Test Facility VUV SASE FEL at DESY operating in a high-gain linear regime with a gain of about 10 6 . It is shown that fluctuations of the output radiation energy follows a gamma-distribution. We also measured for the first time the probability distribution of SASE radiation energy after a narrow-band monochromator. The experimental results are in good agreement with theoretical predictions, the energy fluctuations after the monochromator follow a negative exponential distribution

  10. Procedure for field axes measurement, beam indication adjustment, and figure of convergence determination within performance tests for radiation therapy equipment

    Energy Technology Data Exchange (ETDEWEB)

    Quast, U; Krause, K; Rassow, J [Essen Univ. (Gesamthochschule) (Germany, F.R.). Abt. fuer Klinische Strahlenphysik

    1976-09-01

    A routine measuring procedure for the verification of radiation field axes and figure of convergence within a spatial resolution of +- 0.5 mm is described. Measurements are done in two parallel planes in a certain distance before and behind the presumed isocentre. The used test arrangement permits rapid check and controlled adjustment of the alignment of beam or isocentre indicating devices for all isocentric radiation therapy equipment.

  11. Accelerated radiation damage test facility using a 5 MV tandem ion accelerator

    International Nuclear Information System (INIS)

    Wady, P.T.; Draude, A.; Shubeita, S.M.; Smith, A.D.; Mason, N.; Pimblott, S.M.; Jimenez-Melero, E.

    2016-01-01

    We have developed a new irradiation facility that allows to perform accelerated damage tests of nuclear reactor materials at temperatures up to 400 °C using the intense proton (<100 μA) and heavy ion (≈10 μA) beams produced by a 5 MV tandem ion accelerator. The dedicated beam line for radiation damage studies comprises: (1) beam diagnosis and focusing optical components, (2) a scanning and slit system that allows uniform irradiation of a sample area of 0.5–6 cm"2, and (3) a sample stage designed to be able to monitor in-situ the sample temperature, current deposited on the sample, and the gamma spectrum of potential radio-active nuclides produced during the sample irradiation. The beam line capabilities have been tested by irradiating a 20Cr–25Ni–Nb stabilised stainless steel with a 3 MeV proton beam to a dose level of 3 dpa. The irradiation temperature was 356 °C, with a maximum range in temperature values of ±6 °C within the first 24 h of continuous irradiation. The sample stage is connected to ground through an electrometer to measure accurately the charge deposited on the sample. The charge can be integrated in hardware during irradiation, and this methodology removes uncertainties due to fluctuations in beam current. The measured gamma spectrum allowed the identification of the main radioactive nuclides produced during the proton bombardment from the lifetimes and gamma emissions. This dedicated radiation damage beam line is hosted by the Dalton Cumbrian Facility of the University of Manchester.

  12. Le traumatisme du colon: l'expérience du CHU Hassan II de Fès

    Science.gov (United States)

    Benjelloun, El Bachir; Hafid, Hasnai; Karim, Ibnmajdoub; Ousadden, Abdelmalek; Mazaz, Khalid; Taleb, Kahlid Ait

    2012-01-01

    Introduction Les traumatismes du colon sont associés à un risque majeur de complications septiques et de mortalité. Le but de notre étude est d’évaluer les circonstances, la prise en charge, le suivi et les facteurs pronostic de morbidité postopératoire des malades victimes d'un traumatisme colique. Méthodes Il s'agit d'une étude rétrospective sur une série de 49 patients opérés pour des plaies coliques aux services de chirurgie viscérale du CHU HASSAN II de Fès sur une période de 8 ans de juillet 2003 à juillet 2011. Résultats L’âge moyen de nos patients était de 25ans (16-70) avec une nette prédominance masculine (93.8%). Les plaies coliques secondaires à un traumatisme par arme blanche représentent 85% des cas (42 patients), suivi par les plaies iatrogènes au cours d'une coloscopie chez 6 patients (13%), puis les contusions abdominales chez 1 patient (2%). Les parties du cadre colique les plus touchées étaient le colon transverse chez 19 patients (38%) et le colon descendant chez 12 patients (24, 5%). Le colon sigmoïde était le segment le plus touché au cours d'une coloscopie4/6. Quarante-deux patients (85%) ont eu une suture primaire des plaies coliques, six patients (13%) une diversion fécale et un patient (2%) une résection-anastomose. Deux patients (4%) sont décédés suite à un choc septique. La morbidité globale était de 38,7% dominé essentiellement par l'infection de la paroi chez 14 patients et une péritonite post opératoire chez 3 patients. L'analyse univarié a montré une différence significatif en terme d'infection de la paroi entre le groupe colostomie versus suture simple (50% vs 20,9% p<0,05). L'atteinte du colon gauche et la réalisation d'une colostomie sont associés à un risque plus élevés de complications postopératoires. Conclusion La suture primaire peut être effectuée avec un faible taux de complications postopératoire chez la majorité des patients suite à un traumatisme du colon. PMID

  13. Testing of bulk radiation damage of n-in-p silicon sensors for very high radiation environments

    Czech Academy of Sciences Publication Activity Database

    Hara, K.; Affolder, A.A.; Allport, P.P.; Bates, R.; Betancourt, C.; Böhm, Jan; Brown, H.; Buttar, C.; Carter, J. R.; Casse, G.; Mikeštíková, Marcela

    2011-01-01

    Roč. 636, č. 1 (2011), "S83"-"S89" ISSN 0168-9002 R&D Projects: GA MŠk LA08032 Institutional research plan: CEZ:AV0Z10100502 Keywords : p-bulk silicon * microstrip * charge collection * radiation damage Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 1.207, year: 2011 http://dx.doi.org/10.1016/j.nima.2010.04.090

  14. Remotely-Sensed Mapping of Irrigation Area in the Chu-Talas River Basin in Central Asia and Application to Compliance Monitoring of Transboundary Water Sharing

    Science.gov (United States)

    Ragettli, S.; Siegfried, T.; Herberz, T.

    2017-12-01

    In the Central Asian Chu-Talas River Basin, farmers depend on freshwater from international rivers to irrigate their fields during the summer growing season. While the allocation percentages of water sharing between up- and downstream are defined for both rivers, marked interannual supply variability plus inadequate monitoring renders the compliance with these quotas difficult. In such circumstances, data on irrigated area obtained by remote sensing can be used to map the extent of irrigation in terms of its area on at national and subnational scales. Due to its transparency on how the data was obtained (freely available satellite data) and processed, this objective measure could potentially be used as a data product for confidence building and for compliance monitoring. This study assesses the extent and location of irrigated areas over the period 2000 - 2016 in the basins by using state-of-the-art remote sensing technology. Using a random forest classifier, an automated irrigated cropland mapping algorithm was implemented in Google Earth Engine using Landsat 7 data. First, a training set was established through visual interpretation (irrigated and non-irrigated classes for the year 2015) and the classifier then trained. The classier was then applied on a series of seasonal greenest pixels image mosaics from 2000 to 2016. A four-stepped accuracy assessment confirmed that the classifier yielded robust, reliable and reproducible results. Outcomes indicate that irrigated areas in the Kyrgyz side of the Talas Basin approximately doubled by 2016 since 2000 while the irrigated area in the Kazakh part of the basin did not significantly change over the 17 year time period. In the Chu River Basin, total irrigated area tripled since 2000. Comparison with officially reported statistics shows differences and points to reporting issues in both countries. We conclude that remote sensing of irrigated areas in arid and semi-arid regions in combination with cloud computing offers

  15. Projected impacts of climate change on hydrology, water resource use and adaptation needs for the Chu and Talas cross-border rivers basin, Central Asia

    Science.gov (United States)

    Shamil Iliasov, Shamil; Dolgikh, Svetlana; Lipponen, Annukka; Novikov, Viktor

    2014-05-01

    The observed long-term trends, variability and projections of future climate and hydrology of the Chu and Talas transboundary rivers basin were analysed using a common approach for Kazakhstan and Kyrgyzstan parts of the basin. Historical, current and forecasted demands and main uses of water in the basin were elaborated by the joint effort of both countries. Such cooperative approach combining scientific data, water practitioners' outlook with decision making needs allowed the first time to produce a comprehensive assessment of climate change impacts on water resources in the Chu-Talas transboundary rivers basin, identify future needs and develop the initial set of adaptation measures and recommendations. This work was carried out under the project "Promoting Cooperation to Adapt to Climate Change in the Chu and Talas Transboundary Basin", supported by the United Nations Economic Commission for Europe (UNECE) and the United Nations Development Programme (UNDP). Climate change projections, including air temperatures and rainfall in the 21st century were determined with a spatial resolution 0.5 degrees based on the integration of 15 climate change model outputs (derived from IPCC's 4th Assessment Report, and partially 5th Assessment Report) combined with locally-designed hydrology and glacier models. A significant increase in surface air temperatures by 3-6°C may be expected in the basin area, especially in summer and autumn. This change is likely to be accompanied by rainfall increase during the cold season and a decrease in the warm half of the year. As a result, a deterioration of moisture conditions during the summer-autumn period is possible. Furthermore, milder winters and hotter summers can be expected. Mountains will likely receive more liquid precipitation, than snow, while the area and volume of glaciers may significantly reduce. Projected changes in climate and glaciers have implications for river hydrology and different sectors of the economy dependent

  16. Accelerated radiation damage test facility using a 5 MV tandem ion accelerator

    Science.gov (United States)

    Wady, P. T.; Draude, A.; Shubeita, S. M.; Smith, A. D.; Mason, N.; Pimblott, S. M.; Jimenez-Melero, E.

    2016-01-01

    We have developed a new irradiation facility that allows to perform accelerated damage tests of nuclear reactor materials at temperatures up to 400 °C using the intense proton (spectrum of potential radio-active nuclides produced during the sample irradiation. The beam line capabilities have been tested by irradiating a 20Cr-25Ni-Nb stabilised stainless steel with a 3 MeV proton beam to a dose level of 3 dpa. The irradiation temperature was 356 °C, with a maximum range in temperature values of ±6 °C within the first 24 h of continuous irradiation. The sample stage is connected to ground through an electrometer to measure accurately the charge deposited on the sample. The charge can be integrated in hardware during irradiation, and this methodology removes uncertainties due to fluctuations in beam current. The measured gamma spectrum allowed the identification of the main radioactive nuclides produced during the proton bombardment from the lifetimes and gamma emissions. This dedicated radiation damage beam line is hosted by the Dalton Cumbrian Facility of the University of Manchester.

  17. Radiation protection clothes in X-ray-diagnostics. Comparison of test methods

    International Nuclear Information System (INIS)

    Pichler, T.; Schoepf, T.; Ennemoser, O.

    2009-01-01

    For testing the attenuation of the protection clothes the standard EN 61331-1 for attenuation measurements in the ''narrow and broad beam'' is available as well as the DIN 6857-1 for determination of shielding properties in the so called ''inverse broad-beam geometry''. The attenuation measurements in the narrow beam don't consider scattered radiation and fluorescence due to the arrangement. This leads to the fact that the protective effect of lead-free-Materials will be miss-estimated when compared to lead. In this work the measurements of shielding properties in inverse broad-beam geometry according to the DIN 6857-1 were compared with attenuation measurements according to the EN 61331-1. Also the dependence of the chamber was studied. Attenuation measurements were performed with lead- and lead-free-materials. Additional certificated lead-foils with high purity and precise thickness of 0.1 to 2 mm were used. For measuring a cylinder chamber of 30 cm 3 and two flat chambers of 75 cm 3 (SFD) and 112 cm 3 (FC) were used. The measurements in inverse broad-beam geometry according to the DIN 6857-1 show adequate results, also in testing lead-free protection materials. The results in attenuation correspond to a large extent to those, which are determined by measurements in the broad beam. When performing measurements in inverse geometry however the characteristic of the used chamber is not negligible. (orig.)

  18. First tests of a novel radiation hard CMOS sensor process for Depleted Monolithic Active Pixel Sensors

    International Nuclear Information System (INIS)

    Pernegger, H.; Hoorne, J.W. van; Kugathasan, T.; Musa, L.; Riedler, P.; Riegel, C.; Schaefer, D.; Schioppa, E.J.; Snoeys, W.; Bates, R.; Buttar, C.; Maneuski, D.; Dalla, M.; Sbarra, C.

    2017-01-01

    The upgrade of the ATLAS [1] tracking detector for the High-Luminosity Large Hadron Collider (LHC) at CERN requires novel radiation hard silicon sensor technologies. Significant effort has been put into the development of monolithic CMOS sensors but it has been a challenge to combine a low capacitance of the sensing node with full depletion of the sensitive layer. Low capacitance brings low analog power. Depletion of the sensitive layer causes the signal charge to be collected by drift sufficiently fast to separate hits from consecutive bunch crossings (25 ns at the LHC) and to avoid losing the charge by trapping. This paper focuses on the characterization of charge collection properties and detection efficiency of prototype sensors originally designed in the framework of the ALICE Inner Tracking System (ITS) upgrade [2]. The prototypes are fabricated both in the standard TowerJazz 180nm CMOS imager process [3] and in an innovative modification of this process developed in collaboration with the foundry, aimed to fully deplete the sensitive epitaxial layer and enhance the tolerance to non-ionizing energy loss. Sensors fabricated in standard and modified process variants were characterized using radioactive sources, focused X-ray beam and test beams before and after irradiation. Contrary to sensors manufactured in the standard process, sensors from the modified process remain fully functional even after a dose of 10"1"5 n _e_q/cm"2, which is the the expected NIEL radiation fluence for the outer pixel layers in the future ATLAS Inner Tracker (ITk) [4].

  19. Lower Bound for the Radiation $Q$ of Electrically Small Magnetic Dipole Antennas With Solid Magnetodielectric Core

    DEFF Research Database (Denmark)

    Kim, Oleksiy S.; Breinbjerg, Olav

    2011-01-01

    A new lower bound for the radiation $Q$ of electrically small spherical magnetic dipole antennas with solid magnetodielectric core is derived in closed form using the exact theory. The new bound approaches the Chu lower bound from above as the antenna electrical size decreases. For $ka, the new...... bound is lower than the bounds for spherical magnetic as well as electric dipole antennas composed of impressed electric currents in free space....

  20. Modeling UV Radiation Feedback from Massive Stars. I. Implementation of Adaptive Ray-tracing Method and Tests

    Science.gov (United States)

    Kim, Jeong-Gyu; Kim, Woong-Tae; Ostriker, Eve C.; Skinner, M. Aaron

    2017-12-01

    We present an implementation of an adaptive ray-tracing (ART) module in the Athena hydrodynamics code that accurately and efficiently handles the radiative transfer involving multiple point sources on a three-dimensional Cartesian grid. We adopt a recently proposed parallel algorithm that uses nonblocking, asynchronous MPI communications to accelerate transport of rays across the computational domain. We validate our implementation through several standard test problems, including the propagation of radiation in vacuum and the expansions of various types of H II regions. Additionally, scaling tests show that the cost of a full ray trace per source remains comparable to that of the hydrodynamics update on up to ∼ {10}3 processors. To demonstrate application of our ART implementation, we perform a simulation of star cluster formation in a marginally bound, turbulent cloud, finding that its star formation efficiency is 12% when both radiation pressure forces and photoionization by UV radiation are treated. We directly compare the radiation forces computed from the ART scheme with those from the M 1 closure relation. Although the ART and M 1 schemes yield similar results on large scales, the latter is unable to resolve the radiation field accurately near individual point sources.

  1. The Semipalatinsk nuclear test site: a first assessment of the radiological situation and the test-related radiation doses in the surrounding territories.

    Science.gov (United States)

    Gusev, B I; Abylkassimova, Z N; Apsalikov, K N

    1997-09-01

    As a result of atmospheric nuclear tests at the Semipalatinsk test site 'Polygon', adjacent territories were contaminated by radionuclide fallout. The population of some districts in the Semipalatinsk oblast were exposed to elevated levels of radiation. Contamination and exposure mostly resulted from early atmospheric tests. The radiological situation of the Semipalatinsk oblast is described. Effective dose estimates due to external and internal exposure attributable to the 1949 and 1953 tests in villages near the Polygon range from 70 mSv to 4470 mSv.

  2. Effect on intelligence test score of prenatal exposure to ionizing radiation in Hiroshima and Nagasaki

    International Nuclear Information System (INIS)

    Schull, W.J.; Otake, Masanori; Yoshimaru, Hiroshi.

    1988-10-01

    Analyses of intelligence test scores (Koga) at 10-11 years of age of individuals exposed prenatally to the atomic bombing of Hiroshima and Nagasaki using estimates of the uterine absorbed dose based on the recently introduced system of dosimetry, the Dosimetry System 1986 (DS86), reveal the following: 1) there is no evidence of a radiation-related effect on intelligence among those individuals exposed within 0-7 weeks after fertilization or in the 26th or subsequent weeks; 2) for individuals exposed at 8-15 weeks after fertilization, and to a lesser extent those exposed at 16-25 weeks, the mean tests scores but not the variances are significantly heterogeneous among exposure categories; 3) the cumulative distribution of test scores suggests a progressive shift downwards in individual scores with increasing exposure; and 4) within the group most sensitive to the occurrence of clinically recognizable severe mental retardation, individuals exposed 8 through 15 weeks after fertilization, the regression of intelligence score on estimated DS86 uterine absorbed dose is more linear than with T65DR fetal dose, the diminution in intelligence score under the linear model is 21-29 points at 1Gy. The effect is somewhat greater when the controls receiving less than 0.01 Gy are excluded, 24-33 points at 1 Gy. These findings are discussed in the light of the earlier analysis of the frequency of occurrence of mental retardation among the prenatally exposed survivors of the A-bombing of Hiroshima and Nagasaki. It is suggested that both are the consequences of the same underlying biological process or processes. (author)

  3. Morbidity and immunological tests in miners working in mines with low ionizing radiation level

    International Nuclear Information System (INIS)

    Wagner, V.; Skokanova, V.; Skokanova, K.; Wagnerova, M.; Heribanova, A.; Riha, M.

    1984-01-01

    The total count of morbidity and prevalence of upper respiratory tract diseases (RTD) were studied in 210 miners working in shale mines with a low level of ionizing radiation with respect to their smoking habits. After one and a half years of observation tests of humoral immunity in the blood serum and saliva (immunoglobulins G, A, M and sIA) and tests of non-specific indices (alpha 2 macroglobulin (A 2M), transferrin, lysozyme) were performed. The number of healthy non-smokers reached 41.3% whereas the number of healthy smokers was only 26.5% (P<0.05). The greater was the number of diseases in single subjects, the greater was the difference between smokers and non-smokers (P<0.005). The difference between RTD morbidity of smokers and non-smokers was not significant in the subgroup of miners employed less than 10 years but the duration of employment raised the value significantly (P<0.002) in disfavour of smokers. The difference between smokers and non-smokers is emphasized in ageing. The mean levels of immunoglobulins (IgG, IgA, IgM) were significantly higher in healthy non-smokers in comparison with other miners; this is also stressed by distribution analysis. The distribution of A 2M values also significantly differed in the subgroup of healthy non-smokers compared with other miners. Highly significant differences were found between healthy non-smokers and other miners using discrimination analysis of coupled tests. In contrast to that, the level of A 2M was in inverse relationship to the levels of Ig; in the subgroup of healthy non-smokers low levels of A 2M correlated with high levels of Ig of all three classes. The results are discussed from the point of view of the smokers' habits, the duration of employment in the mine, the age of the miners and the presumed genetical factors

  4. Ion chamber-electrometer measurement system for radiation protection tests in X-ray equipment for interventional procedures

    International Nuclear Information System (INIS)

    Bottaro, Marcio

    2012-01-01

    A new parallel plate ionization chamber with volume of 500 cc and an electrometer with digital interface for data acquisition, configuring an ion chamber electrometer measurement system, were developed to comply with specific requirements for compulsory radiation protection tests in interventional X-ray equipment. The ion chamber has as main characteristics: low cost, mechanical strength and response variation with beam energy of less than 5% in the 40 kV to 150 kV range. The electrometer has a high gain (5x10 8 V/A) transimpedance amplifier circuit and a data acquisition and control system developed in LabVIEW ® platform, including an integrated power supply for the ion chamber bias with adjustable DC voltage output from O to 1000 V and an air density correction system. Electric field calculations, laboratory measurements in standard beams and computational simulations of radiation interactions in chamber volume with Monte Carlo Method were employed in the elaborated methodology of the ion chamber development, which was tested and validated. It was also developed a simplified methodology for electrometer calibration that assures metrological trustworthiness of the measurement system. Tests for the system performance evaluation as environmental influence response, energy response, angular dependency, linearity and air kerma and air kerma rate dependency were performed according to international standards and requirements. Additionally, for a detailed evaluation of the developed ion chamber, simulations with various scattered radiation spectra were performed. The system was applied in leakage radiation, residual radiation and scattered radiation tests, being compared with other reference systems and validated for laboratorial test routine. (author)

  5. Individual response to ionising radiation: What predictive assay(s) to choose?; Reponse individuelle aux radiations ionisantes: quel(s) test(s) predictif(s) choisir?

    Energy Technology Data Exchange (ETDEWEB)

    Granzotto, A.; Viau, M.; Devic, C.; Maalouf, M.; Thomas, Ch.; Vogin, G.; Foray, N. [Inserm, U836, groupe de radiobiologie, institut des neurosciences, chemin Fortune-Ferrini, 38042 Grenoble (France); Granzotto, A.; Vogin, G.; Balosso, J. [Centre de hadrontherapie Etoile, 69008 Lyon (France); Joubert, A. [Societe Magelis, 84160 Cadenet (France); Maalouf, M. [Centre national d' etudes spatiales, 75001 Paris (France); Vogin, G.; Colin, C. [EA 3738, faculte de medecine, Lyon-Sud, 69921 Oullins (France); Malek, K.; Balosso, J. [Service de radiotherapie, CHU A.-Michallon, 38042 Grenoble (France); Colin, C. [Service de radiologie, CHU Lyon-Sud, 69490 Pierre-Benite (France)

    2011-02-15

    Individual response to ionizing radiation is an important information required to apply an efficient radiotherapy treatment against tumour and to avoid any adverse effects in normal tissues. In 1981, Fertil and Malaise have demonstrated that the post-irradiation local tumor control determined in vivo is correlated with clonogenic cell survival assessed in vitro. Furthermore, these authors have reminded the relevance of the concept of intrinsic radiosensitivity that is specific to each individual organ (Fertil and Malaise, 1981) [1]. To date, since clonogenicity assays are too time-consuming and do not provide any other molecular information, a plethora of research groups have attempted to determine the molecular bases of intrinsic radiosensitivity in order to propose reliable and faster predictive assays. To this aim, several approaches have been developed. Notably, the recent revolution in genomic and proteomics technologies is providing a considerable number of data but their link with radiosensitivity still remains to be elucidated. On another hand, the systematic screening of some candidate genes potentially involved in the radiation response is highlighting the complexity of the molecular and cellular mechanisms of DNA damage sensing and signalling and shows that an abnormal radiation response is not necessarily due to the impairment of one single protein. Finally, more modest approaches consisting in focusing some specific functions of DNA repair seem to provide more reliable clues to predict over-acute reactions caused by radiotherapy. In this review, we endeavored to analyse the contributions of these major approaches to predict human radiosensitivity. (authors)

  6. The HAW-Project. Test disposal of highly radioactive radiation sources in the Asse salt mine. Final report

    International Nuclear Information System (INIS)

    Rothfuchs, T.; Cuevas, C. de las; Donker, H.; Feddersen, H.K.; Garcia-Celma, A.; Gies, H.; Goreychi, M.; Graefe, V.; Heijdra, J.; Hente, B.; Jockwer, N.; LeMeur, R.; Moenig, J.; Mueller, K.; Prij, J.; Regulla, D.; Smailos, E.; Staupendahl, G.; Till, E.; Zankl, M.

    1995-01-01

    In order to improve the final concept for the disposal of high-level radioactive waste (HAW) in boreholes drilled into salt formation plans were developed a couple of years ago for a full scale testing of the complete technical system of an underground repository. To satisfy the test objectives, thirty highly radioactive radiation sources were planned to be emplaced in six boreholes located in two test galleries at the 800-m-level in the Asse salt mine. A duration of testing of approximately five years was envisaged. Because of licensing uncertainties the German Federal Government decided on December 3rd, 1992 to stop all activities for the preparation of the test disposal immediately. In the course of the preparation of the test disposal, however, a system, necessary for handling of the radiation sources was developed and installed in the Asse salt mine and two non-radioactive reference tests with electrical heaters were started in November 1988. These tests served for the investigation of thermal effects in comparison to the planned radioactive tests. An accompanying scientific investigation programme performed in situ and in the laboratory comprises the estimation and observation of the thermal, radiation-induced, and mechanical interaction between the rock salt and the electrical heaters and the radiation sources, respectively. The laboratory investigations are carried out at Braunschweig (FRG), Petten (NL), Saclay (F) and Barcelona (E). As a consequence of the premature termination of the project the working programme was revised. The new programme agreed to by the project partners included a controlled shutdown of the heater tests in 1993 and a continuation of the laboratory activities until the end of 1994. (orig.)

  7. Design of a synchrotron radiation detector for the test beam lines at the Superconducting Super Collider Laboratory

    International Nuclear Information System (INIS)

    Hutton, R.D.

    1994-01-01

    As part of the particle- and momentum-tagging instrumentation required for the test beam lines of the Superconducting Super Collider (SSC), the synchrotron radiation detector (SRD) was designed to provide electron tagging at momentum above 75 GeV. In a parallel effort to the three test beam lines at the SSC, schedule demands required testing and calibration operations to be initiated at Fermilab. Synchrotron radiation detectors also were to be installed in the NM and MW beam lines at Femilab before the test beam lines at the SSC would become operational. The SRD is the last instrument in a series of three used in the SSC test beam fines. It follows a 20-m drift section of beam tube downstream of the last silicon strip detector. A bending dipole just in of the last silicon strip detector produces the synchrotron radiation that is detected in a 50-mm-square cross section NaI crystal. A secondary scintillator made of Bicron BC-400 plastic is used to discriminate whether it is synchrotron radiation or a stray particle that causes the triggering of the NaI crystal's photo multiplier tube (PMT)

  8. [Research on Japanese monograph of comprehensive dietetic materia medica, the Pao chu bei yong wo ming ben cao (Japanese Materia Medica Prepared for Kitchen)].

    Science.gov (United States)

    Zhou, M; Ye, J

    2017-11-28

    Japanese physicians of Edo Period (1603-1867) wrote many dietetic books, by combining the knowledge system (content and compiling style) and thoughts of diet therapy from China with local condition in Japan. Among them, the Pao chu bei yong wo ming ben cao ( Japanese Materia Medica Prepared for Kitchen ), written by Mukai Genshou, a physician in the early Edo, is the earliest comprehensive work of dietetic materia medica. In this book, the choice and usage of Japanese dietetic materia medica reveals obvious Japanese local color, including the name, morphology, cultivation, collection, identification, nature and flavor, and indication etc., reflecting the sprouting idea of edible herbal plant at the beginning of Edo period and the characteristic of absorbing Chinese diet thoughts by Japanese physician. This is the important first-hand historical material to understand the development of Japanese dietetic herbalism in early Edo and its dietotherapy culture.

  9. Enrico Fermi Awards Ceremony for Dr. Mildred S. Dresselhaus and Dr. Burton Richter, May 2012 (Presentations, including remarks by Energy Secretary, Dr. Steven Chu)

    International Nuclear Information System (INIS)

    Chu, Steven

    2012-01-01

    The Fermi Award is a Presidential award and is one of the oldest and most prestigious science and technology honors bestowed by the U.S. Government. On May 7, 2012 it was conferred upon two exceptional scientists: Dr. Mildred Dresselhaus, 'for her scientific leadership, her major contributions to science and energy policy, her selfless work in science education and the advancement of diversity in the scientific workplace, and her highly original and impactful research,' and Dr. Burton Richter, 'for the breadth of his influence in the multiple disciplines of accelerator physics and particle physics, his profound scientific discoveries, his visionary leadership as SLAC Director, his leadership of science, and his notable contributions in energy and public policy.' Dr. John Holder, Director of the White House Office of Science and Technology Policy, opened the ceremony, and Dr. Bill Brinkman, Director of DOE's Office of Science introduced the main speaker, Dr. Steven Chu, U.S. Energy Secretary.

  10. Radiative cooling test facility and performance evaluation of 4-MIL aluminized polyvinyl fluoride and white-paint surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Kruskopf, M.S.; Berdahl, P.; Martin, M.; Sakkal, F.; Sobolewski, M.

    1980-11-01

    A test facility designed to measure the amount of radiative cooling a specific material or assembly of materials will produce when exposed to the sky is described. Emphasis is placed upon assemblies which are specifically designed to produce radiative cooling and which therefore offer promise for the reduction of temperatures and/or humidities in occupied spaces. The hardware and software used to operate the facility are documented and the results of the first comprehensive experiments are presented. A microcomputer-based control/data acquisition system was employed to study the performance of two prototype radiator surfaces: 4-mil aluminized polyvinyl fluoride (PVF) and white painted surfaces set below polyethylene windscreens. The cooling rates for materials tested were determined and can be approximated by an equation (given). A computer model developed to simulate the cooling process is presented. (MCW)

  11. Structural and ultrastructural study of rat testes influenced by electromagnetic radiation.

    Science.gov (United States)

    Almášiová, Viera; Holovská, Katarína; Cigánková, Viera; Račeková, Enikö; Fabianová, Kamila; Martončíková, Marcela

    2014-01-01

    This study was conducted to investigate the influence of whole-body electromagnetic radiation (EMR) on testicular parenchyma of Wistar rats. Sexually mature rats were subjected to pulsed electromagnetic field at frequency of 2.45 GHz and mean power density 2.8 mW/cm(2) by 3-h daily applications for 3 wk. Tissue samples were obtained 3 h after the last irradiation and processed by histological techniques for light and transmission electron microscopy. Testes showed apparent degenerative changes of seminiferous epithelium. The seminiferous tubules were mostly irregular in shape, and seminiferous epithelium contained a number of empty spaces of different size. Subsequently, groups of sloughed epithelial cells were often found inside the lumina of tubules. Except for relatively unchanged Sertoli cells, some locations of basal compartment of seminiferous epithelium contained shriveled Sertoli cells with dark cytoplasm. These areas showed degenerative features including necrotizing and shriveled spermatogonia surrounded by empty irregular spaces, and undulating basement membrane. The intertubular spaces were enlarged but interstitial Leydig cells did not show any marked morphological changes. Evidence demonstrates the adverse effects of EMR on testicular parenchyma in rats.

  12. Beam test of novel n-in-p strip sensors for high radiation environment

    Science.gov (United States)

    Kubota, T.; Kishida, T.; Jinnouchi, O.; Ikegami, Y.; Unno, Y.; Terada, S.; Mitsui, S.; Tamii, A.; Aoi, T.; Hanagaki, K.; Hara, K.; Kimura, N.; Takashima, R.; Takubo, Y.; Tojo, J.; Nagai, K.; Nakano, I.; Yorita, K.

    2013-12-01

    Highly radiation tolerant n-in-p strip sensors have been developed for the high-luminosity LHC (HL-LHC). This paper reports the results of measurements with 392 MeV kinetic energy proton beam at RCNP in December 2011. The data was taken with a new DAQ system consisting of an universal read-out board ‘SEABAS’ and beam tracking telescopes whose spacial resolution is better than 5 μm. The aim of this beam test is to evaluate the new 1 cm×1 cm n-in-p miniature sensors before and after 1015 neq cm-2 irradiation. The median charge of un-irradiated sensor is 6.2 fC at full depletion voltage, while the median charge after 1015 neq cm-2 irradiation of the sensor is 4.2 fC. The novel Punch-Through-Protection (PTP) has been implemented in these sensors. The length of active region of the sensor around PTP is observed to be decreased by 12 μm in the irradiated sensors at 1015 neq cm-2.

  13. Measurements and radiation tests on scintillating fibres for the LHCb SciFi project

    CERN Document Server

    Joram, Christian; Shatalov, Pavel

    2014-01-01

    This note describes a number of measurements and a radiation test performed on the baseline fibre of the LHCb SciFi upgrade project. These include measurements of the optical attenuation length - globally and wavelength resolved -, measurements of the photoelectric yield, and finally the assessment of the impact of proton irradiation on these quantities. The fibres were irradiated at the CERN PS with 24 GeV/c protons up to a fluence of 7•10$^{13}$ p/cm$^2$ equivalent to an ionizing dose of about 22 kGy. Measurements on the fibres, in particular in view of possible recovery effects, are still ongoing and the report is expected to be updated in the coming months. This report is meant as backup document for the LHCb internal SciFi review in February 2013. It had to be produced in a short available time. Missing information will be added and style as well as formatting will be improved in the forthcoming version.

  14. Calorific energy deposited by gamma radiations in a test reactor. Calorimetric measurements and calculations

    International Nuclear Information System (INIS)

    Mecheri, K.-F.

    1977-01-01

    The purpose of this work was to determine the calorific energy deposited by gamma radiations in the experimental devices irradiated in the test reactors of the Grenoble Nuclear Study Centre. A theoretical study briefly recalls to mind the various sorts of nuclear reactions that occur in a reactor, from the special angle of their ability to deposit calorific energy in the materials. A special study with the help of a graphite calorimeter made it possible to show the possible effect of the various parameters intervening in this energy absorption: the nature of the materials, their geometry, the spectrum of the incident gamma rays and the fact that the variation of this spectrum is due to the position of the measuring point with respect to the reactor core or to the presence of structures around the measuring instrument. The results of the calculations made with the help of the Mercury IV and ANISN codes are compared with those of the determinations in order to ascertain that very are adapted to the forecasts of energy deposition in the various materials. The conclusion was reached that in order to calculate with accuracy the depositifs of gamma energy in the experimental devices, it is necessary either to introduce the build-up calculation for the low energy photons, in the Mercury IV calculation code or to associate the DOT code to the ANISN calculation code [fr

  15. Micronucleus test for radiation biodosimetry in mass casualty events: Evaluation of visual and automated scoring

    Energy Technology Data Exchange (ETDEWEB)

    Bolognesi, Claudia, E-mail: claudia.bolognesi@istge.i [Environmental Carcinogenesis Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Balia, Cristina; Roggieri, Paola [Environmental Carcinogenesis Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Cardinale, Francesco [Clinical Epidemiology Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Department of Health Sciences, University of Genoa, Genoa (Italy); Bruzzi, Paolo [Clinical Epidemiology Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Sorcinelli, Francesca [Environmental Carcinogenesis Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Laboratory of Genetics, Histology and Molecular Biology Section, Army Medical and Veterinary, Research Center, Via Santo Stefano Rotondo 4, 00184 Roma (Italy); Lista, Florigio [Laboratory of Genetics, Histology and Molecular Biology Section, Army Medical and Veterinary, Research Center, Via Santo Stefano Rotondo 4, 00184 Roma (Italy); D' Amelio, Raffaele [Sapienza, Universita di Roma II Facolta di Medicina e Chirurgia and Ministero della Difesa, Direzione Generale Sanita Militare (Italy); Righi, Enzo [Frascati National Laboratories, National Institute of Nuclear Physics, Via Enrico Fermi 40, 00044 Frascati, Rome (Italy)

    2011-02-15

    In the case of a large-scale nuclear or radiological incidents a reliable estimate of dose is an essential tool for providing timely assessment of radiation exposure and for making life-saving medical decisions. Cytogenetics is considered as the 'gold standard' for biodosimetry. The dicentric analysis (DA) represents the most specific cytogenetic bioassay. The micronucleus test (MN) applied in interphase in peripheral lymphocytes is an alternative and simpler approach. A dose-effect calibration curve for the MN frequency in peripheral lymphocytes from 27 adult donors was established after in vitro irradiation at a dose range 0.15-8 Gy of {sup 137}Cs gamma rays (dose rate 6 Gy min{sup -1}). Dose prediction by visual scoring in a dose-blinded study (0.15-4.0 Gy) revealed a high level of accuracy (R = 0.89). The scoring of MN is time consuming and requires adequate skills and expertise. Automated image analysis is a feasible approach allowing to reduce the time and to increase the accuracy of the dose estimation decreasing the variability due to subjective evaluation. A good correlation (R = 0.705) between visual and automated scoring with visual correction was observed over the dose range 0-2 Gy. Almost perfect discrimination power for exposure to 1-2 Gy, and a satisfactory power for 0.6 Gy were detected. This threshold level can be considered sufficient for identification of sub lethally exposed individuals by automated CBMN assay.

  16. Molecular phylogeny of selected species of the order Dinophysiales (Dinophyceae) - testing the hypothesis of a Dinophysioid radiation

    DEFF Research Database (Denmark)

    Jensen, Maria Hastrup; Daugbjerg, Niels

    2009-01-01

    additional information on morphology and ecology to these evolutionary lineages. We have for the first time combined morphological information with molecular phylogenies to test the dinophysioid radiation hypothesis in a modern context. Nuclear-encoded LSU rDNA sequences including domains D1-D6 from 27...

  17. Method of 16N generation for test of radiation controlled channels at nuclear power stations with water-cooled reactors

    International Nuclear Information System (INIS)

    Khryachkov, V.A.; Bondarenko, I.P.; Dvornikov, P.A.; Zhuravlev, B.V.; Kovtun, S.N.; Khromyleva, T.A.; Pavlov, A.V.; Roshchin, N.G.

    2012-01-01

    The preferences of nuclear reaction use for radiation control channels test in water-cooled power reactors have been analyzed in the paper. The new measurements for more accurate determination of reaction cross section energy dependence have been carried out. A set of new methods for background reducing and improvement of events determination reliability has also been developed [ru

  18. Radiation effect characterization and test methods of single-chip and multi-chip stacked 16Mbit DRAMs

    International Nuclear Information System (INIS)

    LaBel, K.A.; Gates, M.M.; Moran, A.K.; Kim, H.S.; Seidleck, C.M.; Marshall, P.; Kinnison, J.; Carkhuff, B.

    1996-01-01

    This paper presents radiation effects characterization performed by the NASA Goddard Space Flight Center (GSFC) on spaceflight candidate 16Mbit DRAMs. This includes heavy ion, proton, and Co60 irradiations on single-chip devices as well as proton irradiation of a stacked DRAM module. Lastly, a discussion of test methodology is undertaken

  19. Temperature cycling test of planar hyper-pure germanium radiation detector

    International Nuclear Information System (INIS)

    Sakai, Eiji

    1976-01-01

    If a Ge (Li) detector is left at the normal temperature, generally it does not recover its original performance even when it is cooled again with liquid nitrogen, as Li ions in the compensated i zone precipitate by Li drift and it returns to p type which is the state before drift. One of the devices that overcomes this shortcoming is the p-n junction Ge detector, which required the production of high purity Ge single crystals to obtain the thick depletion layer. The planar or coaxial type detectors were produced using the Ge single crystals with impurity concentration of 10 10 /cm 3 and it was recognized that they showed the gamma detecting characteristic nearly equal to Ge (Li) detectors. They are now commercially available from a few companies. The author carried out the temperature-cycling test of the planar type hyperpure Ge detector sold by Nuclear Radiation Developments, Canada. First, applying liquid nitrogen, the leakage current, static capacity, gamma ray-detecting efficiency and energy resolution were measured. Then it was returned to room temperature. Since then, irregular cycling tests were carried out 15 times. The results didn't show any significant change in the gamma ray-detecting efficiency, energy resolution and static capacity. Though leakage current changed between 9.3 and 33 pA, it does not influence on the energy resolution because of small absolute values. It may be said that it is sufficiently stable in the temperature cycling from room temperature to 77 K. (Wakatsuki, Y.)

  20. Accelerated tests for the soft error rate determination of single radiation particles in components of terrestrial and avionic electronic systems

    International Nuclear Information System (INIS)

    Flament, O.; Baggio, J.

    2010-01-01

    This paper describes the main features of the accelerated test procedures used to determine reliability data of microelectronics devices used in terrestrial environment.This paper focuses on the high energy particle test that could be performed through spallation neutron source or quasi-mono-energetic neutron or proton. Improvements of standards are illustrated with respect to the state of the art of knowledge in radiation effects and scaling down of microelectronics technologies. (authors)

  1. Summary of the Manufacture, Testing and Model Validation of a Full-Scale Radiator for Fission Surface Power Applications

    Science.gov (United States)

    Ellis, David L.; Calder, James; Siamidis, John

    2011-01-01

    A full-scale radiator for a lunar fission surface power application was manufactured by Material innovations, Inc., for the NASA Glenn Research Center. The radiator was designed to reject 6 kWt with an inlet water temperature of 400 K and a water mass flow rate of 0.5 kg/s. While not flight hardware, the radiator incorporated many potential design features and manufacturing techniques for future flight hardware. The radiator was tested at NASA Glenn Research Center for heat rejection performance. The results showed that the radiator design was capable of rejecting over 6 kWt when operating at the design conditions. The actual performance of the radiator as a function of operational manifolds, inlet water temperature and facility sink temperature was compared to the predictive model developed by NASA Glenn Research Center. The results showed excellent agreement with the model with the actual average face sheet temperature being within 1% of the predicted value. The results will be used in the design and production of NASA s next generation fission power heat rejection systems. The NASA Glenn Research Center s Technology Demonstration Unit will be the first project to take advantage of the newly developed manufacturing techniques and analytical models.

  2. Standards for Radiation Effects Testing: Ensuring Scientific Rigor in the Face of Budget Realities and Modern Device Challenges

    Science.gov (United States)

    Lauenstein, J M.

    2015-01-01

    An overview is presented of the space radiation environment and its effects on electrical, electronic, and electromechanical parts. Relevant test standards and guidelines are listed. Test standards and guidelines are necessary to ensure best practices, minimize and bound systematic and random errors, and to ensure comparable results from different testers and vendors. Test standards are by their nature static but exist in a dynamic environment of advancing technology and radiation effects research. New technologies, failure mechanisms, and advancement in our understanding of known failure mechanisms drive the revision or development of test standards. Changes to standards must be weighed against their impact on cost and existing part qualifications. There must be consensus on new best practices. The complexity of some new technologies exceeds the scope of existing test standards and may require development of a guideline specific to the technology. Examples are given to illuminate the value and limitations of key radiation test standards as well as the challenges in keeping these standards up to date.

  3. Radiation testing campaign results for understanding the suitability of FPGAs in detector electronics

    Energy Technology Data Exchange (ETDEWEB)

    Citterio, M., E-mail: mauro.citterio@mi.infn.it [INFN Milan, Milan (Italy); Camplani, A. [INFN Milan, Milan (Italy); Cannon, M. [Brigham Young University, Provo (United States); Chen, H.; Chen, K. [Brookhaven National Laboratory, Upton, NY (United States); Deng, B.; Liu, C. [Southern Methodist University, Dallas (United States); Meroni, C. [INFN Milan, Milan (Italy); Kierstead, J.; Takai, H. [Brookhaven National Laboratory, Upton, NY (United States); Wirthlin, M. [Brigham Young University, Provo (United States); Ye, J. [Southern Methodist University, Dallas (United States)

    2016-07-11

    SRAM based Field Programmable Gate Arrays (FPGAs) have been rarely used in High Energy Physics (HEP) due to their sensitivity to radiation. The last generation of commercial FPGAs based on 28 nm feature size and on Silicon On Insulator (SOI) technologies are more tolerant to radiation to the level that their use in front-end electronics is now feasible. FPGAs provide re-programmability, high-speed computation and fast data transmission through the embedded serial transceivers. They could replace custom application specific integrated circuits in front end electronics in locations with moderate radiation field. The use of a FPGA in HEP experiments is only limited by our ability to mitigate single event effects induced by the high energy hadrons present in the radiation field. - Highlights: • Radiation campaign on Xilinx Kintex 7 FPGAs. • Use of FPGAs in high energy physics. • Evaluation of configuration RAM and block RAM parameters after irradiation.

  4. Protective role of Tinospora cordifolia extract against radiation-induced qualitative, quantitative and biochemical alterations in testes

    International Nuclear Information System (INIS)

    Sharma, Priyanka; Parmar, Jyoti; Sharma, Priyanka; Verma, Preeti; Goyal, P.K.

    2012-01-01

    In today's changing global scenario, ionizing radiation is considered as most potent cause of oxidative stress mediated by free radical flux which induces severe damage at various hierarchical levels in the organization in the living organisms. Testis is a highly prolific tissue with fast cellular renewal and poor antioxidant defense; therefore it becomes an easy target for the radiation-induced free radicals that have long been suggested as major cause of male infertility. Chemical radioprotection is an important strategy to countermeasure the deleterious effects of radiation. Several Indian medicinal plants are rich source of antioxidants and these have been used for the treatment of ailments. Tinospora cordifolia, commonly known as amrita, is one of the plants that have several pharmacological and therapeutic properties. Therefore, the present study was performed to evaluate the deleterious effects of semi lethal dose of gamma radiation on testicular tissue and their possible inhibition by Tinospora cordifolia root extract (TCE). For this purpose, healthy Swiss albino male mice were selected from an inbred colony and divided into four groups. Group I (normal) was administered double distilled water (DDW) volume equal to TCE (75 mg/kg.b.wt/animal) by oral gavage. Group II was orally supplemented TCE as 75 mg/kg. b.wt once daily for 5 consecutive days. Group III (irradiated control) received DDW orally equivalent to TCE for 5 days then exposed to 5 Gy gamma radiation. Group IV (experimental) was administered TCE as in Group II and exposed to radiation (as in Group III). Irradiation resulted into significant decrease in the frequency of different spermatogenic cell counts along with severe histo-pathological lesions up to 7th day of irradiation in testes of irradiated control animals, thereafter, recovery followed towards the normal architecture. TCE pretreatment effectively prevented radiation induced such alterations in cellular counts and testicular injuries by

  5. Application of advanced model of radiative heat transfer in a rod geometry to QUENCH and PARAMETER tests

    International Nuclear Information System (INIS)

    Vasiliev, A.D.; Kobelev, G.V.; Astafieva, V.O.

    2007-01-01

    accident. Special attention is paid to deriving of exact analytical values of view factors and mean beam lengths (which are a good tool in radiative heat transfer concerning gas media) for a number of standard geometries. Generalized Hottel's method of strings is used for rods of finite lengths. Monte-Carlo method is used for validation of new model in application to standard geometries. The developed model is successfully applied for modeling of PARAMETER-SF1 and QUENCH-06 tests, which use the triangular and square rod assembly respectively. (author)

  6. SU-F-T-249: Application of Human Factors Methods: Usability Testing in the Radiation Oncology Environment

    Energy Technology Data Exchange (ETDEWEB)

    Warkentin, H [Cross Cancer Institute, Edmonton, AB (Canada); Bubric, K [Alberta Health Services, Calgary, AB (Canada); Giovannetti, H [Jack Ady Cancer Centre, Lethbridge, AB (Canada); Graham, G [Tom Baker Cancer Centre, Calgary, AB (Canada); Clay, C [Central Alberta Cancer Centre, Red Deer, AB (Canada)

    2016-06-15

    Purpose: As a quality improvement measure, we undertook this work to incorporate usability testing into the implementation procedures for new electronic documents and forms used by four affiliated radiation therapy centers. Methods: A human factors specialist provided training in usability testing for a team of medical physicists, radiation therapists, and radiation oncologists from four radiotherapy centers. A usability testing plan was then developed that included controlled scenarios and standardized forms for qualitative and quantitative feedback from participants, including patients. Usability tests were performed by end users using the same hardware and viewing conditions that are found in the clinical environment. A pilot test of a form used during radiotherapy CT simulation was performed in a single department; feedback informed adaptive improvements to the electronic form, hardware requirements, resource accessibility and the usability testing plan. Following refinements to the testing plan, usability testing was performed at three affiliated cancer centers with different vault layouts and hardware. Results: Feedback from the testing resulted in the detection of 6 critical errors (omissions and inability to complete task without assistance), 6 non-critical errors (recoverable), and multiple suggestions for improvement. Usability problems with room layout were detected at one center and problems with hardware were detected at one center. Upon amalgamation and summary of the results, three key recommendations were presented to the document’s authors for incorporation into the electronic form. Documented inefficiencies and patient safety concerns related to the room layout and hardware were presented to administration along with a request for funding to purchase upgraded hardware and accessories to allow a more efficient workflow within the simulator vault. Conclusion: By including usability testing as part of the process when introducing any new document

  7. SU-F-T-249: Application of Human Factors Methods: Usability Testing in the Radiation Oncology Environment

    International Nuclear Information System (INIS)

    Warkentin, H; Bubric, K; Giovannetti, H; Graham, G; Clay, C

    2016-01-01

    Purpose: As a quality improvement measure, we undertook this work to incorporate usability testing into the implementation procedures for new electronic documents and forms used by four affiliated radiation therapy centers. Methods: A human factors specialist provided training in usability testing for a team of medical physicists, radiation therapists, and radiation oncologists from four radiotherapy centers. A usability testing plan was then developed that included controlled scenarios and standardized forms for qualitative and quantitative feedback from participants, including patients. Usability tests were performed by end users using the same hardware and viewing conditions that are found in the clinical environment. A pilot test of a form used during radiotherapy CT simulation was performed in a single department; feedback informed adaptive improvements to the electronic form, hardware requirements, resource accessibility and the usability testing plan. Following refinements to the testing plan, usability testing was performed at three affiliated cancer centers with different vault layouts and hardware. Results: Feedback from the testing resulted in the detection of 6 critical errors (omissions and inability to complete task without assistance), 6 non-critical errors (recoverable), and multiple suggestions for improvement. Usability problems with room layout were detected at one center and problems with hardware were detected at one center. Upon amalgamation and summary of the results, three key recommendations were presented to the document’s authors for incorporation into the electronic form. Documented inefficiencies and patient safety concerns related to the room layout and hardware were presented to administration along with a request for funding to purchase upgraded hardware and accessories to allow a more efficient workflow within the simulator vault. Conclusion: By including usability testing as part of the process when introducing any new document

  8. Off-site environmental monitoring report: Radiation monitoring around United States Nuclear Test areas, Calendar year 1986

    International Nuclear Information System (INIS)

    Patzer, R.G.; Fontana, C.A.; Grossman, R.F.; Black, S.C.; Dye, R.E.; Smith, D.D.; Thome', D.J.; Mullen, A.A.

    1987-05-01

    The principal activity at the NTS is testing of nuclear devices, though other related projects are also conducted. The principal activities of the Off-Site Radiological Safety Program are routine environmental monitoring for radioactive materials in various media and for radiation in areas which may be affected by nuclear tests; and protective actions in support of the nuclear testing program. These are conducted to document compliance with standards, to identify trends, and to provide information to the public. 28 refs., 37 figs., 30 tabs

  9. Overview of a benefit/risk ratio optimized for a radiation emitting device used in non-destructive testing

    Energy Technology Data Exchange (ETDEWEB)

    Maharaj, H.P., E-mail: H_P_Maharaj@hc-sc.gc.ca [Health Canada, Dept. of Health, Consumer and Clinical Radiaton Protection Bureau, Ottawa, Ontario (Canada)

    2016-03-15

    This paper aims to provide an overview of an optimized benefit/risk ratio for a radiation emitting device. The device, which is portable, hand-held, and open-beam x-ray tube based, is utilized by a wide variety of industries for purposes of determining elemental or chemical analyses of materials in-situ based on fluorescent x-rays. These analyses do not cause damage or permanent alteration of the test materials and are considered a non-destructive test (NDT). Briefly, the key characteristics, principles of use and radiation hazards associated with the Hay device are presented and discussed. In view of the potential radiation risks, a long term strategy that incorporates risk factors and guiding principles intended to mitigate the radiation risks to the end user was considered and applied. Consequently, an operator certification program was developed on the basis of an International Standards Organization (ISO) standard (ISO 20807:2004) and in collaboration with various stake holders and was implemented by a federal national NDT certification body several years ago. It comprises a written radiation safety examination and hands-on training with the x-ray device. The operator certification program was recently revised and the changes appear beneficial. There is a fivefold increase in operator certification (Levels 1 a nd 2) to date compared with earlier years. Results are favorable and promising. An operational guidance document is available to help mitigate radiation risks. Operator certification in conjunction with the use of the operational guidance document is prudent, and is recommended for end users of the x-ray device. Manufacturers and owners of the x-ray devices will also benefit from the operational guidance document. (author)

  10. Overview of a benefit/risk ratio optimized for a radiation emitting device used in non-destructive testing

    International Nuclear Information System (INIS)

    Maharaj, H.P.

    2016-01-01

    This paper aims to provide an overview of an optimized benefit/risk ratio for a radiation emitting device. The device, which is portable, hand-held, and open-beam x-ray tube based, is utilized by a wide variety of industries for purposes of determining elemental or chemical analyses of materials in-situ based on fluorescent x-rays. These analyses do not cause damage or permanent alteration of the test materials and are considered a non-destructive test (NDT). Briefly, the key characteristics, principles of use and radiation hazards associated with the Hay device are presented and discussed. In view of the potential radiation risks, a long term strategy that incorporates risk factors and guiding principles intended to mitigate the radiation risks to the end user was considered and applied. Consequently, an operator certification program was developed on the basis of an International Standards Organization (ISO) standard (ISO 20807:2004) and in collaboration with various stake holders and was implemented by a federal national NDT certification body several years ago. It comprises a written radiation safety examination and hands-on training with the x-ray device. The operator certification program was recently revised and the changes appear beneficial. There is a fivefold increase in operator certification (Levels 1 a nd 2) to date compared with earlier years. Results are favorable and promising. An operational guidance document is available to help mitigate radiation risks. Operator certification in conjunction with the use of the operational guidance document is prudent, and is recommended for end users of the x-ray device. Manufacturers and owners of the x-ray devices will also benefit from the operational guidance document. (author)

  11. A strategy for testing the impact of clouds on the shortwave radiation budge of general circulation models: A prototype for the Atmospheric Radiation Measurement Program

    International Nuclear Information System (INIS)

    Cess, R.D.

    1994-01-01

    Cloud-climate interactions are one of the greatest uncertainties in contemporary general circulation models (GCMs), and this study has focused on one aspect of this. Specifically, combined satellite and near-surface shortwave (SW) flux measurements have been used to test the impact of clouds on the SW radiation budgets of two GCMs. Concentration is initially on SW rather than longwave (LW) radiation because, in one of the GCMs used in this study an SW radiation inconsistency causes a LW inconsistency. The surface data consist of near-surface insolation measured by the upward facing pyranometer at the Boulder Atmospheric Observatory tower. The satellite data consist of top of the atmosphere (TOA) albedo data, collocated with the tower location, as determined from the GOES SW spin-scan radiometer. Measurements are made every half hour, with hourly means taken by averaging successive measurements. The combined data are for a 21-day period encompassing 28 June through 18 July 1987 and consist of 202 combined albedo/insolation measurements

  12. Modeling, Testing and Deploying a Multifunctional Radiation Shielding / Hydrogen Storage Unit, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This project addresses two vital problems for long-term space travel activities: radiation shielding and hydrogen storage for power and propulsion. While both...

  13. Radiation treatment of combustion gases: formulation and test of a reaction model

    International Nuclear Information System (INIS)

    Busi, F.; D'Angelantonio, M.; Mulazzani, Q.G.; Raffaelli, V.; Tubertini, O.

    1985-01-01

    A generalized kinetic mechanism for radiation induced oxidation of nitrogen oxides from exhaust gases in the absence of sulfur dioxide is formulated. The responses obtained by the mathematical simulation are in good agreement with reported experimental results. (author)

  14. Study on electromagnetic radiation and mechanical characteristics of coal during an SHPB test

    Science.gov (United States)

    Chengwu, Li; Qifei, Wang; Pingyang, Lyu

    2016-06-01

    Dynamic loads provided by a Split Hopkinson pressure bar are applied in the impact failure experiment on coal with an impact velocity of 4.174-17.652 m s-1. The mechanical property characteristics of coal and an electromagnetic radiation signal can be detected and measured during the experiment. The variation of coal stress, strain, incident energy, dissipated energy and other mechanical parameters are analyzed by the unidimensional stress wave theory. It suggests that with an increase of the impact velocity, the mechanical parameters and electromagnetic radiation increased significantly and the dissipated energy of the coal sample has a high discrete growing trend during the failure process of coal impact. Combined with the received energy of the electromagnetic radiation signal, the relationship between these mechanical parameters and electromagnetic radiation during the failure process of coal burst could be analyzed by the grey correlation model. The results show that the descending order of the gray correlation degree between the mechanical characteristics and electromagnetic radiation energy are impact velocity, maximum stress, the average stress, incident energy, the average strain, maximum strain, the average strain rate and dissipation energy. Due to the correlation degree, the impact velocity and incident energy are relatively large, and the main factor affecting the electromagnetic radiation energy of coal is the energy magnitude. While the relationship between extreme stress and the radiation energy change trend is closed, the stress state of coal has a greater impact on electromagnetic radiation than the strain and destruction which can deepen the research of the coal-rock dynamic disaster electromagnetic monitoring technique.

  15. Experimental test of the shadowing effect in Smith-Purcell radiation

    International Nuclear Information System (INIS)

    Naumenko, G.A.; Potylitsyn, A.P.; Popov, Yu.A.; Shevelev, M.V

    2011-01-01

    The observation of a shadowing effect of a relativistic electron Coulomb field for the Smith-Purcell radiation generation is presented in this paper. For this purpose the surface current from the closest surface of grating element to the electron beam was measured for a downstream one shadowed by upstream element. The experimental results showed that shadowing effect for Smith-Purcell radiation depends on grating geometry.

  16. Test trial radiation vulcanization of natural rubber latex in Jakarta Indonesia

    International Nuclear Information System (INIS)

    Devendra, R.; Kulatunge, S.S.; Chandralal, H.N.K.K.; Kalyani, N.M.V.; Seneviratne, J.; Wellage, S.

    1994-01-01

    Radiation vulcanization of natural rubber latex (RVNRL) can be used to make large quantities of specially stabilized latex. It is possible to obtain RVNRL films of tensile strength over 25 MPa. The films could be either coagulant dipped or cast. It is very important to determine the correct radiation dose which gives the maximum tensile strength. Cross linking density or prevulcanized relax modulus (PRM) at 100% is a reliable property to control the prevulcanization

  17. Test and evaluation of semiconductor components in mixed field radiation monitoring

    International Nuclear Information System (INIS)

    Cardenas, Jose Patricio N.; Madi Filho, Tufic; Rodrigues, Leticia L.C.

    2009-01-01

    Silicon components have found extensive use in nuclear spectroscopy and counting, as described in many articles in the last three decades. These devices have found utility in radiation dosimetry because a diode, for instance, produces a current approximately 18000 times higher than any ionization chamber of equal sensitive volume. This reduces stringent requirements from the electronics used to amplify or integrate the current and / or allows approaching the ideal detector point for the mapping of radiation fields. For better performance, in the case of diodes, they are normally used with high inverse polarity to obtain a deeper barrier, less noise and shorter transit time. The aim of this work was the evaluation of these semiconductor components for application in ionizing radiation fields monitoring, in nuclear research reactors and radiotherapy facilities, for radiation protection and health physics purposes. Experimental configurations to analyze the performance of commercial semiconductors, such as silicon PIN Photodiodes and Silicon Surface Barrier Detectors, were developed and the performance of three different configurations of charge preamplifier with silicon components was also studied. Components were evaluated for application as neutron detectors, using some types of radiators (converters). The radiation response of these silicon components to neutron fields from nuclear research reactors IEA-R1 and IPEN-MB1 (thermal, epithermal and fast neutrons), from beam holes, experimental halls and AmBe neutron sources in laboratory was investigated. (author)

  18. On-Line Radiation Test Facility for Industrial Equipment needed for the Large Hadron Collider at CERN

    CERN Document Server

    Rausch, R

    1999-01-01

    The future Large Hadron Collider to be built at CERN will use superconducting magnets cooled down to 1.2 K. To preserve the superconductivity, the energy deposition dose levels in equipment located outside the cryostat, in the LHC tunnel, are calculated to be of the order of 1 to 10 Gy per year. At such dose levels, no major radiation-damage problems are to be expected, and the possibility of installing Commercial Of The Shelf (COTS) electronic equipment in the LHC tunnel along the accelerator is considered. To this purpose, industrial electronic equipment and circuits have to be qualified and tested against radiation to insure their long term stability and reliability. An on-line radiation test facility has been setup at the CERN Super Proton Synchrotron (SPS) and a program of on-line tests for electronic equipment is ongoing. Equipment tested includes Industrial Programmable Logic Controllers (PLCs) from several manufacturers, standard VME modules, Fieldbuses like Profibus, WorldFIP and CAN, various electro...

  19. Nano lead oxide and epdm composite for development of polymer based radiation shielding material: Gamma irradiation and attenuation tests

    Science.gov (United States)

    Özdemir, T.; Güngör, A.; Akbay, I. K.; Uzun, H.; Babucçuoglu, Y.

    2018-03-01

    It is important to have a shielding material that is not easily breaking in order to have a robust product that guarantee the radiation protection of the patients and radiation workers especially during the medical exposure. In this study, nano sized lead oxide (PbO) particles were used, for the first time, to obtain an elastomeric composite material in which lead oxide nanoparticles, after the surface modification with silane binding agent, was used as functional material for radiation shielding. In addition, the composite material including 1%, 5%, 10%, 15% and 20% weight percent nano sized lead oxide was irradiated with doses of 81, 100 and 120 kGy up to an irradiation period of 248 days in a gamma ray source with an initial dose rate of 21.1 Gy/h. Mechanical, thermal properties of the irradiated materials were investigated using DSC, DMA, TGA and tensile testing and modifications in thermal and mechanical properties of the nano lead oxide containing composite material via gamma irradiation were reported. Moreover, effect of bismuth-III oxide addition on radiation attenuation of the composite material was investigated. Nano lead oxide and bismuth-III oxide particles were mixed with different weight ratios. Attenuation tests have been conducted to determine lead equivalent values for the developed composite material. Lead equivalent thickness values from 0.07 to 0.65 (2-6 mm sample thickness) were obtained.

  20. Prospective evaluation of the effect of ionizing radiation on the bladder tumor-associated (BTA) urine test

    International Nuclear Information System (INIS)

    Crane, Christopher H.; Clark, Maureen M.; Bissonette, Eric A.; Theodorescu, Dan

    1999-01-01

    Purpose: To prospectively evaluate the effect of ionizing radiation on the results of the bladder tumor-associated antigen (BTA) test. By examining this question, we sought to determine its potential use as a monitoring test for the detection of recurrent transitional carcinoma of the bladder in patients who have received prior radiotherapy for bladder preservation. Materials and Methods: Between February 1996 and April 1997, 18 patients with nonbladder pelvic malignancies and no history of bladder cancer, received irradiation to the bladder. These patients were prospectively evaluated using the BTA test at the end of the external-beam radiation (EBRT) and at 3-month follow-up intervals. Urine cytology was analyzed in 16 of the 18 patients at the end of EBRT. A median of 3 separate measurements were made (range 1-6) on each patient. The median dose of EBRT was 50.4 Gy (range 30-68Gy). Seven patients underwent brachytherapy as part of their treatment course. BTA results and time intervals were recorded and analyzed using univariate and Kaplan-Meyer methodologies. Results: A total of 10 (56%) of the 18 patients had a positive BTA test at some time following completion of EBRT. Of the 10 positive tests, 9 returned to negative in a median of 42 weeks from completion of EBRT. Treatment with chemotherapy, brachytherapy, calculated bladder dose, and total external beam dose did not significantly influence either the number of positive tests or the time to resolution of the positive test in this small group of patients. All screened urine samples were negative for malignant cells and 11 (69%) of 16 showed changes consistent with ionizing radiation. Conclusion: Our findings support the hypothesis that ionizing radiation can cause transient positive results in the BTA test, but that these normalize with time. Although it requires further testing, it seems that the BTA test may be useful in the detection of recurrence in patients with bladder cancer who have been treated with

  1. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1, S/N 108 2

    Science.gov (United States)

    Valdez, A.

    2000-01-01

    This is the Engineering Test Report, Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1 SIN 108, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).

  2. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1, S/N 109

    Science.gov (United States)

    Valdez, A.

    2000-01-01

    This is the Engineering Test Report, Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1, S/N 109, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).

  3. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A2, S/N 108, 08

    Science.gov (United States)

    Valdez, A.

    2000-01-01

    This is the Engineering Test Report, Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A2, S/N 108, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).

  4. Test beam studies of possibilities to separate particles with gamma factors above 103 with straw based Transition Radiation Detector

    Science.gov (United States)

    Belyaev, N.; Cherry, M. L.; Doronin, S. A.; Filippov, K.; Fusco, P.; Konovalov, S.; Krasnopevtsev, D.; Kramarenko, V.; Loparco, F.; Mazziotta, M. N.; Ponomarenko, D.; Pyatiizbyantseva, D.; Radomskii, R.; Rembser, C.; Romaniouk, A.; Savchenko, A.; Shulga, E.; Smirnov, S.; Smirnov, Yu; Sosnovtsev, V.; Spinelli, P.; Teterin, P.; Tikhomirov, V.; Vorobev, K.; Zhukov, K.

    2017-12-01

    Measurements of hadron production in the TeV energy range are one of the tasks of the future studies at the Large Hadron Collider (LHC). The main goal of these experiments is a study of the fundamental QCD processes at this energy range, which is very important not only for probing of the Standard Model but also for ultrahigh-energy cosmic particle physics. One of the key elements of these experiments measurements are hadron identification. The only detector technology which has a potential ability to separate hadrons in this energy range is Transition Radiation Detector (TRD) technology. TRD prototype based on straw proportional chambers combined with a specially assembled radiator has been tested at the CERN SPS accelerator beam. The test beam results and comparison with detailed Monte Carlo simulations are presented here.

  5. Test results of the experimental laser device for potato tubers radiation treatment

    International Nuclear Information System (INIS)

    Anufrik, S.S.; Korzun, O.S.

    2007-01-01

    Results of 3 year investigation of the influence of the presowing low intensity laser radiation treatment of potato (Solanum tuberosum L.) tubers with the help of laser device with various spectral composition and exposition on plant growth, development and productivity and potato tubers quality and starch content in the conditions of the Republic of Belarus were presented. Presowing tubers treatment of potato cultivars Sante, Yavar and Arkhideya was realized by He-Ne, Ar-, Cu (in course of 3 and 5 minutes) and CO2 (in course of 5 seconds) lasers. Research results have shown that presowing treatment with CO2 laser promoted the higher (on 1,7-6,6%) potato germination capacity in comparison with the control variant without radiation treatment. Height of potato plants of Sante variety after radiation treatment fell behind the control ones. Haulm quantity per one plant and yield quality did not depend on radiation treatment Treatment with CO2 laser exercised the stimulatory action on productivity of Sante variety without changing the starch content in tubers. Tuber weight increased up to 0,4 kg (0,2 kg in the control variant). Similar effect for Arkhideya and Yavar varieties was obtained after Cu-laser treatment in course of 5 minutes. Radiation treatment with He-Ne laser caused the increased starch accumulation (on 0,4-0,6% in comparison with the control variant) in potato tubers of all studied varieties

  6. 40 CFR Table E-2 to Subpart E of... - Spectral Energy Distribution and Permitted Tolerance for Conducting Radiative Tests

    Science.gov (United States)

    2010-07-01

    ... Permitted Tolerance for Conducting Radiative Tests E Table E-2 to Subpart E of Part 53 Protection of... Reference Methods and Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 Pt. 53, Subpt. E, Table E-2 Table E-2 to Subpart E of Part 53—Spectral Energy Distribution and Permitted Tolerance for...

  7. The fourth phase of the radiative transfer model intercomparison (RAMI) exercise: Actual canopy scenarios and conformity testing

    Czech Academy of Sciences Publication Activity Database

    Widlowski, J. L.; Mio, C.; Disney, M.; Adams, J.; Andredakis, I.; Atzberger, C.; Brennan, J.; Busetto, L.; Chelle, M.; Ceccherini, G.; Colombo, R.; Coté, J. F.; Eenmaee, A.; Essery, R.; Gastellu-Etchegorry, J. P.; Gobron, N.; Grau, E.; Haverd, V.; Homolová, Lucie; Huang, H.; Hunt, L.; Kobayashi, H.; Koetz, B.; Kuusk, A.; Kuusk, J.; Lang, M.; Lewis, P. E.; Lovell, J. L.; Malenovský, Zbyněk; Meroni, M.; Morsdorf, F.; Mottus, M.; Ni-Meister, W.; Pinty, B.; Rautiainen, M.; Schlerf, M.; Somers, B.; Stuckens, J.; Verstraete, M. M.; Yang, W.; Zhao, F.; Zenone, T.

    2015-01-01

    Roč. 169, nov (2015), s. 418-437 ISSN 0034-4257 Institutional support: RVO:67179843 Keywords : forest reflectance model * absolute radiometric calibration * remote-sensing data * Conformity testing * Radiative transfer * Model benchmarking * 3D virtual plant canopy * Digital hemispherical photography * Optical remote sensing * Shared risk * Guarded acceptance * gcos * iso -13528 Subject RIV: EH - Ecology, Behaviour Impact factor: 5.881, year: 2015

  8. Relation between simple cytological test and persistence of disease in radiation-treated uterine cervix carcinomas

    Energy Technology Data Exchange (ETDEWEB)

    Schreiner, P

    1985-07-01

    A cytological study was conducted covering 174 epidermoid uterine cervix carcinoma patients who had been given combined radiation therapy. The changes were assessed in the karyopyknotic index (KPI) as related to radiation therapy and the incidence of local relapses. At the limit KPI value of 10, the average reliability of the method for diagnosing persistence in the group under study was 83.0%. Patients showing KPI of more than 10 at six weeks following the termination of radical radiation therapy represent a poor prognosis group whereas those showing KPI values lower than 10 have good prognosis. The results show that no strict hormonal dependence of the KPI value exists in uterine cervix carcinoma patients; only a different situation exists which is probably due to the tumor-organism interaction or to the metabolism of the tumor itself.

  9. Testing digital recursive filtering method for radiation measurement channel using pin diode detector

    International Nuclear Information System (INIS)

    Talpalariu, C. M.; Talpalariu, J.; Popescu, O.; Mocanasu, M.; Lita, I.; Visan, D. A.

    2016-01-01

    In this work we have studied a software filtering method implemented in a pulse counting computerized measuring channel using PIN diode radiation detector. In case our interest was focalized for low rate decay radiation measurement accuracies improvement and response time optimization. During works for digital mathematical algorithm development, we used a hardware radiation measurement channel configuration based on PIN diode BPW34 detector, preamplifier, filter and programmable counter, computer connected. We report measurement results using two digital recursive methods in statically and dynamically field evolution. Software for graphical input/output real time diagram representation was designed and implemented, facilitating performances evaluation between the response of fixed configuration software recursive filter and dynamically adaptive configuration recursive filter. (authors)

  10. Relation between simple cytological test and persistence of disease in radiation-treated uterine cervix carcinomas

    International Nuclear Information System (INIS)

    Schreiner, P.

    1985-01-01

    A cytological study was conducted covering 174 epidermoid uterine cervix carcinoma patients who had been given combined radiation therapy. The changes were assessed in the karyopyknotic index (KPI) as related to radiation therapy and the incidence of local relapses. At the limit KPI value of 10, the average reliability of the method for diagnosing persistence in the group under study was 83.0%. Patients showing KPI of more than 10 at six weeks following the termination of radical radiation therapy represent a poor prognosis group whereas those showing KPI values lower than 10 have good prognosis. The results show that no strict hormonal dependence of the KPI value exists in uterine ceervix carcinoma patients; only a different situation exists which is probably due to the tumor-organism interaction or to the metabolism of the tumor itself. (author)

  11. Comparison of measured and calculated radiation doses in granite around emplacement holes in the spent-fuel test: Climax, Nevada Test Site

    International Nuclear Information System (INIS)

    van Konynenburg, R.A.

    1982-01-01

    Lawrence Livermore National Laboratory (LLNL) has emplaced eleven spent nuclear-reactor fuel assemblies in the Climax granite at the Nevada Test Site as part of the DOE Nevada Nuclear-Waste Storage Investigations. One of our objectives is to study radiation effects on the rock. The neutron and gamma-ray doses to the rock have been determined by MORSE-L Monte Carlo calculations and measurements using optical absorption and thermoluminescence dosimeters and metal foils. We compare the results to date. Generally, good agreement is found in the spatial and time dependence of the doses, but some of the absolute dose results appear to differ by more than the expected uncertainties. Although the agreement is judged to be adequate for radiation effects studies, suggestions for improving the precision of the calculations and measurements are made

  12. Characteristics of radiated power for various TFTR [Tokamak Fusion Test Reactor] regimes

    International Nuclear Information System (INIS)

    Bush, C.E.; Schivell, J.; McNeill, D.H.

    1988-04-01

    Power loss studies were carried out to determine the impurity radiation and energy transport characteristics of various TFTR operation and confinement regimes including L-Mode, detached plasma, co-only neutral beam injection (energetic ion regime), and the enhanced confinement (''supershot'') regime. Combined bolometric, spectroscopic, and infrared photometry measurements provide a picture of impurity behavior and power accounting in TFTR. The purpose of this paper is to make a survey of the various regimes with the aim of determining the radiated power signatures of each. 10 refs., 6 figs., 1 tab

  13. System tests of radiation hard optical links for the ATLAS semiconductor tracker

    International Nuclear Information System (INIS)

    Charlton, D.G.; Dowell, J.D.; Homer, R.J.; Jovanovic, P.; Kenyon, I.R.; Mahout, G.; Shaylor, H.R.; Wilson, J.A.; Rudge, A.; Fopma, J.; Mandic, I.; Nickerson, R.B.; Shield, P.; Wastie, R.; Weidberg, A.R.; Eek, L.-O.; Go, A.; Lund-Jensen, B.; Pearce, M.; Soederqvist, J.; Morrissey, M.; White, D.J.

    2000-01-01

    A prototype optical data and Timing, Trigger and Control transmission system based on LEDs and PIN-diodes has been constructed. The system would be suitable in terms of radiation hardness and radiation length for use in the ATLAS SemiConductor Tracker. Bit error rate measurements were performed for the data links and for the links distributing the Timing, Trigger and Control data from the counting room to the front-end modules. The effects of cross-talk between the emitters and receivers were investigated. The advantages of using Vertical Cavity Surface Emitting Lasers (VCSELs) instead of LEDs are discussed

  14. Test of the neoclassical theory of radiation in a weakly excited atomic system

    International Nuclear Information System (INIS)

    Brink, G.O.

    1975-01-01

    The neoclassical theory of radiation predicts that the decay rate of an excited atomic state depends on the population density of the lower state. Experimental evidence is presented here which shows that in the case of 39 K the decay rate is in agreement with the predictions of quantum electrodynamics and definitely in disagreement with the neoclassical theory

  15. The laboratory testing system for radiation rsistance investigations of integrated circuits

    International Nuclear Information System (INIS)

    Wronski, W.; Wislowski, J.

    1986-01-01

    In order to evaluate the radiation tolerance of integrated circuits MCY 7102 type /MOS RAM/ two devices were built: isotope arrangement for irradiation, and portable tester registering every error of storage block which consists of 32 IC's. Principle of operation and construction of this devices is described. Exemplary results of investigations are shown. (author)

  16. Preliminary radiation protection tests for the body height and body weight of the Chinese reference man

    International Nuclear Information System (INIS)

    Shan, Z.Y.; Chang, Z.Y.; Lan, W.Z.; Yin, G.A.; Li, G.F.

    1985-01-01

    The radiation protection standard recommended by ICRP was evaluated in terms of its suitability for Chinese people. The body height and weight of 100,325 healthy Chinese were measured and anatomical data collected from usable corpses of persons who died by accident or sudden death. The data included the size and weight of certain organs. 18 refs

  17. Health status of radiation exposed residents living near the Semipalatinsk Nuclear Test Site based on health assessment by interview

    International Nuclear Information System (INIS)

    Hirabayashi, Kyoko; Kawano, Noriyuki; Ohtaki, Megu; Harada, Yuka; Hoshi, Masaharu; Hadara, Hironori; Muldagaliyev, Talgat; Apsalikov, Kazbek

    2008-01-01

    The purpose of the present paper is to examine the aftereffects of radiation exposure on residents of villages near the Semipalatinsk Nuclear Test Site (SNTS) in Kazakhstan. Our Hiroshima University (Japan) research team began field research in 2002 by means of health assessments conducted via interviews. We focus on persons who responded to questions concerning their medical conditions and symptoms. In this paper, we summarize and analyze, using multiple linear logistic regression analysis, the answers obtained by questionnaire survey. The results show: 31% of the residents reported that they felt bad or were in very poor health. Residents living in villages having higher radiation levels were more likely to report having poor or very poor health, minor complaints such as loss of sleep, headaches, nighttime sweating and swollen arms or legs, and the need for nursing care in performing activities of daily living. Symptoms reported by over 40% of the respondents included high blood pressure, heart disease and arthralgia/lower back pain/arthritis. Our results suggest that radiation exposure in the Semipalatinsk area is one of the causes of poor health in general among residents. There is also a possibility that radiation exposure has influenced the incidence of some specific medical conditions. (author)

  18. Health status of radiation exposed residents living near the Semipalatinsk Nuclear Test Site based on health assessment by interview.

    Science.gov (United States)

    Hirabayashi, Kyoko; Kawano, Noriyuki; Ohtaki, Megu; Harada, Yuka; Harada, Hironori; Muldagaliyev, Talgat; Apsalikov, Kazbek; Hoshi, Masaharu

    2008-03-01

    The purpose of the present paper is to examine the aftereffects of radiation exposure on residents of villages near the Semipalatinsk Nuclear Test Site (SNTS) in Kazakhstan. Our Hiroshima University (Japan) research team began field research in 2002 by means of health assessments conducted via interviews. We focus on persons who responded to questions concerning their medical conditions and symptoms. In this paper, we summarize and analyze, using multiple linear logistic regression analysis, the answers obtained by questionnaire survey. The results show: (1) 31% of the residents reported that they felt bad or were in very poor health. (2) Residents living in villages having higher radiation levels were more likely to report having poor or very poor health, minor complaints such as loss of sleep, headaches, nighttime sweating and swollen arms or legs, and the need for nursing care in performing activities of daily living. (3) Symptoms reported by over 40% of the respondents included high blood pressure, heart disease and arthralgia/ lower back pain/ arthritis. Our results suggest that radiation exposure in the Semipalatinsk area is one of the causes of poor health in general among residents. There is also a possibility that radiation exposure has influenced the incidence of some specific medical conditions.

  19. Testing the assessment of new radiation oncology technology and treatments framework using the evaluation of post-prostatectomy radiotherapy techniques

    International Nuclear Information System (INIS)

    Duchesne, Gillian M.; Haworth, Annette; Hornby, Colin; Bone, Eric; Carter, Hannah; Martin, Andrew; Ebert, Martin A.; Gagliardi, Frank; Gibbs, Adrian; Sidhom, Mark; Wood, Maree; Jackson, Michael

    2016-01-01

    We tested the ability of the Assessment of New Radiation Oncology Technology and Treatments framework to determine the clinical efficacy and safety of intensity-modulated radiation therapy (IMRT) compared with 3-dimensional radiation therapy (3DCRT) for post-prostatectomy radiation therapy (PPRT) to support its timely health economic evaluation. Treatment plans produced using FROGG guidelines provided dosimetry parameters for both techniques at 64 Gy and 70 Gy and were also used to model early and late outcome probabilities. Clinical parameters were derived from early toxicity and quality of life patient data, systematic literature review and expert opinion. Dosimetry parameters were correlated with the measures of clinical efficacy and safety. Data from two patient cohorts (29 and 27 respectively) were collected within the project timeframe, providing evidence for acute toxicity and quality of life, and dosimetric comparisons. Relative rates of tumour control probability (TCP) and normal tissue control probability (NTCP) modelling were readily derived from the planning exercise and demonstrated advantages in uncomplicated TCP for IMRT over 3DCRT, predominantly due to normal tissue sparing. The safety of IMRT delivery was demonstrated with TCP uncompromised by IMRT protocol violations, which achieved rectal sparing only by reducing minimum target dose and coverage. Sources of desk-top and patient-based evidence were successfully used to demonstrate potential improved clinical efficacy and safety of applying dose escalation using IMRT instead of 3DCRT in PPRT.

  20. SU-E-T-243: Design of a Novel Testing Port for Radiation Protection and Shielding Measurements

    International Nuclear Information System (INIS)

    Tanny, S; Parsai, E; Harrell, D; Noller, J; Chopra, M

    2015-01-01

    Purpose: The majority of radiation shielding research utilizes Monte Carlo simulation because of the difficulty in eliminating secondary radiations from measurements. We have designed a test port into a primary barrier of our newest vault to allow for shielding measurements while ensuring adequate protection to the public and staff during normal machine operation. This port allows for measurement of attenuation values of shielding materials, differential dose albedos, and radiation scatter fractions. Methods: The vault design utilized the maze as part of a compound primary barrier. The test port is contained within the maze and is centered along isocenter. The inner 30 cm has a 20×20 cm 2 opening, while the remaining length has a 30×30 cm 2 opening. The block that contains the port has a density of 200 pcf to minimize internal scatter. The 30×30 cm 2 opening is occupied by removable 215 pcf concrete blocks. The innermost and outermost blocks activate an interlock wired into the beam-enable loop. This disallows beam-on in treatment mode if the interlock isn’t closed. The interlock can be overridden in service mode, or by-passed via an override switch in case of circuit failure. Results: The test port was installed in August. The beam is disabled when the interlock is tripped. Measurements taken when the primary beam is not incident on the port are indistinguishable from background. Ambient dose levels surrounding the vault with the designed shielding blocks in place are all within allowable limits for occupational workers. Conclusions: We have designed and installed a unique testing port for radiation protection and shielding measurements. This port is appropriately interlocked and designed to mitigate any risks of incidental exposure to staff or members of the public. The test port design allows measurements with “good geometry” and efficient removal of contaminating sources of radiation present in many shielding measurements. Daniel Harrell and Jim Noller

  1. Geological affinity of reflecting boundaries in the intermediate structural stage of the Chu Sarysuyskiy depression based on results of vertical seismic profilling

    Energy Technology Data Exchange (ETDEWEB)

    Davydov, N.G.; Kiselevskiy, Yu.N.

    1983-01-01

    A computer (EVM) and an ASOI-VSP-SK program complex are used to analyze data from seismic exploration and acoustical logging with interval by interval calculation of the velocity every four meters. Vertical seismic profilling (VSP) results are used to identify all the upper layers as reference layers. The basic reference level, the third, which corresponds to the floor of the carbonate middle to upper Visean series, is not sustained due to the thin layered state of the terrigeneous section. Based on data from vertical seismic profilling, the reflected wave method (MOV) and the common depth point method (MOGT), the reference 3-a and 6-a levels are identified. Deep reflections of the seventh, 7-a and Rf, approximately confined to the roof and floor of the lower Paleozoic deposits and the upper part of the upper reef series, are noted in the series of the Caledonian cap of the Prebaykal massifs based on vertical seismic profilling. Collector levels are noted on the basis of the frequency of the wave spectra and from the absorption coefficient in the Testas structure and in other low amplitude structures. The insufficiency of the depth capability of the common depth point method and the poor knowledge level of seismic exploration of the section of the lower Paleozoa and the upper Proterozoa of the Chu Sarysuyskiy depresion are noted.

  2. Radiation resistance of elastomeric O-rings in mixed neutron and gamma fields: Testing methodology and experimental results

    Science.gov (United States)

    Zenoni, A.; Bignotti, F.; Donzella, A.; Donzella, G.; Ferrari, M.; Pandini, S.; Andrighetto, A.; Ballan, M.; Corradetti, S.; Manzolaro, M.; Monetti, A.; Rossignoli, M.; Scarpa, D.; Alloni, D.; Prata, M.; Salvini, A.; Zelaschi, F.

    2017-11-01

    Materials and components employed in the presence of intense neutron and gamma fields are expected to absorb high dose levels that may induce deep modifications of their physical and mechanical properties, possibly causing loss of their function. A protocol for irradiating elastomeric materials in reactor mixed neutron and gamma fields and for testing the evolution of their main mechanical and physical properties with absorbed dose has been developed. Four elastomeric compounds used for vacuum O-rings, one fluoroelastomer polymer (FPM) based and three ethylene propylene diene monomer rubber (EPDM) based, presently available on the market have been selected for the test. One EPDM is rated as radiation resistant in gamma fields, while the other elastomers are general purpose products. Particular care has been devoted to dosimetry calculations, since absorbed dose in neutron fields, unlike pure gamma fields, is strongly dependent on the material composition and, in particular, on the hydrogen content. The products have been tested up to about 2 MGy absorbed dose. The FPM based elastomer, in spite of its lower dose absorption in fast neutron fields, features the largest variations of properties, with a dramatic increase in stiffness and brittleness. Out of the three EPDM based compounds, one shows large and rapid changes in the main mechanical properties, whereas the other two feature more stable behaviors. The performance of the EPDM rated as radiation resistant in pure gamma fields does not appear significantly better than that of the standard product. The predictive capability of the accelerated irradiation tests performed as well as the applicable concepts of threshold of radiation damage is discussed in view of the use of the examined products in the selective production of exotic species facility, now under construction at the Legnaro National Laboratories of the Italian Istituto Nazionale di Fisica Nucleare. It results that a careful account of dose rate effects

  3. Radiation monitoring and dosimetry near the semipalatinsk nuclear test site. Radioecological situation, exposure of the population of the semipalatinsk region

    International Nuclear Information System (INIS)

    Stepanenko, V.F.; Tsyb, A.F.; Bogatyriova, T.I.

    1993-01-01

    Evaluation of radioecological situation around the nuclear test site as well as estimation of radioecological situation after the underground nuclear test of July 8, 1989 has been carried out. Radiation doses received by the public for the period of surface and atmospheric nuclear tests conducted from 1949 until 1963 about 10000 individuals received additional external and internal doses. The highest accumulated effective doses were estimated in the residuals of Dolon (1.6 Gy the first nuclear test of 1949), Karaul (0.37 Gy), Sarzhal (0.20 Gy). Semenovka (0.02 Gy). Yearly effective doses for the residents of Semipalatinsk during that period did not exceed 0.0056 Gy (maximum value). Collective doses were estimated for different periods from 1949 to 1989 too. Results of measuring of the environmental exposure gamma dose rates in the inspected areas and soil, plants, water, milk, meat radioactive contamination are presented too

  4. A study of longwave radiation codes for climate studies: Validation with ARM observations and tests in general circulation models

    International Nuclear Information System (INIS)

    Ellingson, R.G.; Baer, F.

    1993-01-01

    This report summarizes the activities of our group to meet our stated objectives. The report is divided into sections entitled: Radiation Model Testing Activities, General Circulation Model Testing Activities, Science Team Activities, and Publications, Presentations and Meetings. The section on Science Team Activities summarizes our participation with the science team to further advance the observation and modeling programs. Appendix A lists graduate students supported, and post-doctoral appointments during the project. Reports on the activities during each of the first two years are included as Appendix B. Significant progress has been made in: determining the ability of line-by-line radiation models to calculate the downward longwave flux at the surface; determining the uncertainties in calculated the downwelling radiance and flux at the surface associated with the use of different proposed profiling techniques; intercomparing clear-sky radiance and flux observations with calculations from radiation codes from different climate models; determining the uncertainties associated with estimating N* from surface longwave flux observations; and determining the sensitivity of model calculations to different formulations of the effects of finite sized clouds

  5. Perceived risks from radiation and nuclear testing near Semipalatinsk, Kazakhstan: a comparison between physicians, scientists, and the public.

    Science.gov (United States)

    Purvis-Roberts, Kathleen L; Werner, Cynthia A; Frank, Irene

    2007-04-01

    Determining the difference in perception of risk between experts, or more educated professionals, and laypeople is important so that a potential hazard can be effectively communicated to the public. Many surveys have been conducted to better understand the difference between expert and public opinions, and often laypeople exhibit higher perceptions of risk to hazards in comparison to experts. This is especially true when health risk is due to radiation, nuclear power, and nuclear waste. This article focuses on one section of a risk perception survey given to two groups of individuals with a more specialized education (scientists and physicians) and laypeople (villagers) in the Semipalatinsk region of Kazakhstan. All of these groups live near the former Soviet nuclear test site. Originally, it was expected that the scientists and physicians would have similar perceptions of radiation risk, while the public perceptions would be higher, but this was not always the case. For example, when perceptions of risk pertain to the health impacts of nuclear testing or the dose-response nature of radiation exposure, the physicians tend to agree with the laypeople, not the scientists. The villagers are always the most risk-averse group, followed by the physicians and then the scientists. These differences are likely due to different frames of reference for each of the populations.

  6. Kazakhstan-Japan joint study on health effects of radiation in residents in and around former Semipalatinsk Nuclear Test Site

    International Nuclear Information System (INIS)

    Toshiaki Ogiu; Yoshiro Aoki; Sadayoshi Kobayashi; Shizuyo Kusumi; Jiro Inaba; Kenzhina, G.; Berezin, S.; Zhotabaev, Zh.; Berezina, M.; Sekerbayev, A.; Lukashenko, S.

    2008-01-01

    Full text: The National Nuclear Center of the Republic of Kazakhstan (NNC RK) and the Radiation Effects Association (REA, Japan) are now jointly carrying out 'Study on Health Effects of Radiation in Residents in and around the Former Semipalatinsk Nuclear Test Site (STS)' commissioned by the Ministry of Education, Culture, Sports, Science and Technology (MEXT) of Japanese Government. This joint study between Kazakhstan and Japan was initiated in 2001 in response to the request from the government of the Republic of Kazakhstan and to the resolution of the 53rd United Nations General Assembly in 1998 for providing the Kazakhstan with medical, environmental, economical and humanitarian assistance to the residents in and around Semipalatinsk Test Site. The purpose of the study is to obtain scientific evidence on the health effects of chronic and repeated long-term exposure to low level mixed (external and internal) radiation in residents in and around Semipalatinsk Test Site, and thereby to provide fundamental scientific information on the nature and extent of health effects that might have been incurred by such exposures. The mode of this type of exposure (chronic long-term mixed radiation) is conceivable in the current situation of exposure such as occupational exposure, but different from those of Hiroshima and Nagasaki in Japan where the exposure was mainly acute and external. In this study, exposed populations are consisting of residents of Dolon, Znamenka, Karaul, and Kainar (Semipalatinsk population - 1) and that of Southern Beskaragai Region including Mostik, Cheremushki, Bol'shaya Vladimirovka, Malaya Vladimirovka, Budene, Semenovka, etc. (Semipalatinsk population - 2). Control populations are consisting of residents of Kenzhekol, Kenes and Zhanaaul (Pavlodar Population - 1) and that of Kachiry, Irtyshsk and Sherbakty (Pavlodar Population - 2). As of the end of July, 2008, personal data (date of birth, gender, race, etc.) were collected for 117,300 persons

  7. Validity and reliability testing of two instruments to measure breast cancer patients' concerns and information needs relating to radiation therapy

    Directory of Open Access Journals (Sweden)

    Kristjanson Linda J

    2007-11-01

    Full Text Available Abstract Background It is difficult to determine the most effective approach to patient education or tailor education interventions for patients in radiotherapy without tools that assess patients' specific radiation therapy information needs and concerns. Therefore, the aim of this study was to develop psychometrically sound tools to adequately determine the concerns and information needs of cancer patients during radiation therapy. Patients and Methods Two tools were developed to (1 determine patients concerns about radiation therapy (RT Concerns Scale and (2 ascertain patient's information needs at different time point during their radiation therapy (RT Information Needs Scale. Tools were based on previous research by the authors, published literature on breast cancer and radiation therapy and information behaviour research. Thirty-one breast cancer patients completed the questionnaire on one occasion and thirty participants completed the questionnaire on a second occasion to facilitate test-retest reliability. One participant's responses were removed from the analysis. Results were analysed for content validity, internal consistency and stability over time. Results Both tools demonstrated high internal consistency and adequate stability over time. The nine items in the RT Concerns Scale were retained because they met all pre-set psychometric criteria. Two items were deleted from the RT Information Needs Scale because they did not meet content validity criteria and did not achieve pre-specified criteria for internal consistency. This tool now contains 22 items. Conclusion This paper provides preliminary data suggesting that the two tools presented are reliable and valid and would be suitable for use in trials or in the clinical setting.

  8. Photonuclear and Radiation Effects Testing with a Refurbished 20 MeV Medical Electron Linac

    CERN Document Server

    Webb, Timothy; Beezhold, Wendland; De Veaux, Linda C; Harmon, Frank; Petrisko, Jill E; Spaulding, Randy

    2005-01-01

    An S-band 20 MeV electron linear accelerator formerly used for medical applications has been recommissioned to provide a wide range of photonuclear activation studies as well as various radiation effects on biological and microelectronic systems. Four radiation effect applications involving the electron/photon beams are described. Photonuclear activation of a stable isotope of oxygen provides an active means of characterizing polymer degradation. Biological irradiations of microorganisms including bacteria were used to study total dose and dose rate effects on survivability and the adaptation of these organisms to repeated exposures. Microelectronic devices including bipolar junction transistors (BJTs) and diodes were irradiated to study photocurrent from these devices as a function of peak dose rate with comparisons to computer modeling results. In addition, the 20 MeV linac may easily be converted to a medium energy neutron source which has been used to study neutron damage effects on transistors.

  9. Irradiation test of component for radiation-resistant small sized motor

    International Nuclear Information System (INIS)

    Nakamichi, M.; Ishitsuka, E.; Shimakawa, S.; Kan, S.

    2009-01-01

    A small-sized motor with a resistance to radiation was developed. This motor has been able to operate at a gamma-ray dose of a value 700 times as high as the specification of a commercial motor. The present work describes results of post-irradiation examinations (PIEs) to evaluate effects of neutron irradiation on the lifetime of some major components of the motor such as a bearing, a magnet and a fixation agent for a field coil wire. It became clear from the results of PIEs that the radiation-resistance dose of the motor using a Sm-Co magnet will be expected to be one order of magnitude higher than that of the motor using a Nb-Fe-B magnet.

  10. The characteristics of Fugi IP Cassette Type PII and application for radiation oncology quality assurance tests and portal imaging

    International Nuclear Information System (INIS)

    Soh, H.S.; Ung, N.M.; Ng, K.H.

    2008-01-01

    Full text: The advancement of digital imaging has prompted more medical institutions to go filmless. The computed radiography (CR) system is becoming an important tool not only in diagnostic imaging, but also in radiation oncology. A new CR system that was specially designed for the use in radiation oncology. Fuji IP cassette type PII has been introduced to the market in the middle of year 2006. This project aimed to study some basic physical characteristics of this new type of cassette and explore its application for performing quality assurance (QA) tests and portal imaging in radiotherapy. All the images were read by FCR 5000 Plus reader. The image was found to reach its saturation value of 1023 (due to the image was stored in 10 bits data) by depending on the sensitivity value being adjusted. The uniformity test gave the result of 0.12%. The cassette was used to perform the QA tests which were previously performed using film. All the results met the specification as stated in AAPM Task Group 40. The comparison for the portal images of Portal Vision contrast-detail phantom showed that the spatial resolution of the images obtained by CR system (Fujifilm Co.. Ltd.. Tokyo. Japan) were better than the EPID (Varian Medical Systems. Inc.. Palo Alto. USA) and film system (Eastman Kodak Co.. New York. USA). The IP cassette type PII was found to be suitable as an alternative QA test tool and portal imaging in radiotherapy.

  11. Standard Practice for Minimizing Dosimetry Errors in Radiation Hardness Testing of Silicon Electronic Devices Using Co-60 Sources

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice covers recommended procedures for the use of dosimeters, such as thermoluminescent dosimeters (TLD's), to determine the absorbed dose in a region of interest within an electronic device irradiated using a Co-60 source. Co-60 sources are commonly used for the absorbed dose testing of silicon electronic devices. Note 1—This absorbed-dose testing is sometimes called “total dose testing” to distinguish it from “dose rate testing.” Note 2—The effects of ionizing radiation on some types of electronic devices may depend on both the absorbed dose and the absorbed dose rate; that is, the effects may be different if the device is irradiated to the same absorbed-dose level at different absorbed-dose rates. Absorbed-dose rate effects are not covered in this practice but should be considered in radiation hardness testing. 1.2 The principal potential error for the measurement of absorbed dose in electronic devices arises from non-equilibrium energy deposition effects in the vicinity o...

  12. Installation And Test Of Electron Beam Generation System To Produce Far-Infrared Radiation And X-Ray Pulses

    International Nuclear Information System (INIS)

    Wichaisirimongkol, Pathom; Jinamoon, Witoon; Khangrang, Nopadon; Kusoljariyakul, Keerati; Rhodes, Michael W.; Rimjaem, Sakhorn; Saisut, Jatuporn; Chitrlada, Thongbai; Vilaithong, Thiraphat; Wiedemann, Helmut

    2005-10-01

    SURIYA project at the Fast Neutron Research Facility, Chiang Mai University, aims to establish a facility to generate femtosecond electron beams. This electron beam can be used to generate high intensity far-infrared radiation and ultra-short X-ray pulses. The main components of the system are a 3 MeV RF electron gun with a thermionic cathode, an a-magnet as a bunch compressor, and post acceleration 15-20 MeV by a linear accelerator (linac). Between the main components, there are focusing quadrupole magnets and steering magnets to maintain the electron beam within a high vacuum tube. At the end of the beam transport line, a dipole magnet has been installed to function as a beam dump and an energy spectrometer. After the installation and testing of individual major components were completed, we have been investigating the generation of the electron beam, intense far- infrared radiation and ultra short X-ray pulses

  13. Pre-criticality testing of radiation monitors associated with protective and regulatory channels of PHWRs and related work

    International Nuclear Information System (INIS)

    Tripathi, S.M.; Rao, Suresh; Mahant, A.K.; Sathian, V.; Ghodke, Shobha; Satam, R.A.; Singh, Yashoda; Phadnis, U.V.; Shaha, V.V.

    2006-01-01

    The paper describes the various experiments that are regularly carried out for each PHWR since RAPS-2. The work involves performance evaluation of start-up counters and ion chambers used in Protective and Regulatory channels and start-up counters used both in-core and out of core. In addition, Radiation Safety Systems Division (RSSD) also carries out calibration of Delayed Neutron Monitors (DNM) and Self Powered Neutron Detectors (SPND). Except SPND, all other detectors are tested not only at BARC but also at reactor sites prior to initial flushing of heavy water, using the actual circuitry and control instruments at site. The performance evaluation of SPNDs is carried out at A-1 location of APSARA reactor core. Apart from these, RSSD also carries out calibration of zonal classification monitors and health physics related radiation monitors at BARC. (author)

  14. Combined performance tests before installation of the ATLAS Semiconductor and Transition Radiation Tracking Detectors

    Czech Academy of Sciences Publication Activity Database

    Abat, E.; Abdesselam, A.; Andy, T.N.; Böhm, Jan; Šťastný, Jan

    2008-01-01

    Roč. 3, - (2008), P08003/1-P08003/67 ISSN 1748-0221 R&D Projects: GA MŠk LA08032; GA MŠk 1P04LA212 Institutional research plan: CEZ:AV0Z10100502 Keywords : solid state detectors * particle tracking detectors * large detector systems for particle and astroparticle physics * transition radiation detectors Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 0.333, year: 2008

  15. Radiation shielding tests in the Meson beamline in the master substation area

    International Nuclear Information System (INIS)

    Coleman, R.; Kissel, W.; Leveling, A.; Moore, C.D.; Vylet, V.

    1991-04-01

    A review of shielding uncovered a weak region in a portion of the proton beam transport to the Meson Area. Preliminary CASIM Monte Carlo studies indicated dose rates at the surface under abnormal operating conditions would be above the Fermilab Radiation Guide limits. Measurements made on December 15 and 16 confirmed this concern. Further comparisons of data with CASIM predictions are discussed. 5 refs., 22 figs., 8 tabs

  16. Radiation detectors for use in major public events: classification, requirements, main features, tests and lessons learned

    International Nuclear Information System (INIS)

    Souza, Elder Magalhães de

    2017-01-01

    Since September 11, 2001, we have entered a new terrorism era. The possibility of the use of lost/stolen radioactive materials increases the probability of a radiological threat. The real goal intended with the use of a Radiological Dispersal Device (RRD or dirty bomb) or a Radiation Exposure Device (RDE) could be psychological in nature. Panic in the venues and surrounding area would cause more deaths than the RDD itself, therefore these attempts could cause chaos, injury, fear and terror, the main target of terrorists. The response of the national authorities with the support and aid of the IAEA served as an increase of the capability of detection and identification of nuclear and radiological materials. But this response could not be limited only to the MPE, because if the country has radioactive or nuclear facilities they also should be considered in terms of theft, sabotage, illegal transfer, unauthorized access, and any other malicious acts. In 2007, Rio de Janeiro, received the first Brazilian Major Public Event in this new era. This was the first Brazilian operation which largely utilized detectors (personal radiations detectors -PRD- radiological identification detectors, -RID or RIID- and spectral radiations scanners, -backpacks-, HPGe detectors, car-borne and air-borne systems) to protect the venues, the athletes, the population and the environment. (author)

  17. Radiation detectors for use in major public events: classification, requirements, main features, tests and lessons learned

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Elder Magalhães de, E-mail: elder@ird.gov.br [Instituto de Radioproteção e Dosimetria (DIRAD/IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Radiometria

    2017-07-01

    Since September 11, 2001, we have entered a new terrorism era. The possibility of the use of lost/stolen radioactive materials increases the probability of a radiological threat. The real goal intended with the use of a Radiological Dispersal Device (RRD or dirty bomb) or a Radiation Exposure Device (RDE) could be psychological in nature. Panic in the venues and surrounding area would cause more deaths than the RDD itself, therefore these attempts could cause chaos, injury, fear and terror, the main target of terrorists. The response of the national authorities with the support and aid of the IAEA served as an increase of the capability of detection and identification of nuclear and radiological materials. But this response could not be limited only to the MPE, because if the country has radioactive or nuclear facilities they also should be considered in terms of theft, sabotage, illegal transfer, unauthorized access, and any other malicious acts. In 2007, Rio de Janeiro, received the first Brazilian Major Public Event in this new era. This was the first Brazilian operation which largely utilized detectors (personal radiations detectors -PRD- radiological identification detectors, -RID or RIID- and spectral radiations scanners, -backpacks-, HPGe detectors, car-borne and air-borne systems) to protect the venues, the athletes, the population and the environment. (author)

  18. Using the FLUKA Monte Carlo Code to Simulate the Interactions of Ionizing Radiation with Matter to Assist and Aid Our Understanding of Ground Based Accelerator Testing, Space Hardware Design, and Secondary Space Radiation Environments

    Science.gov (United States)

    Reddell, Brandon

    2015-01-01

    Designing hardware to operate in the space radiation environment is a very difficult and costly activity. Ground based particle accelerators can be used to test for exposure to the radiation environment, one species at a time, however, the actual space environment cannot be duplicated because of the range of energies and isotropic nature of space radiation. The FLUKA Monte Carlo code is an integrated physics package based at CERN that has been under development for the last 40+ years and includes the most up-to-date fundamental physics theory and particle physics data. This work presents an overview of FLUKA and how it has been used in conjunction with ground based radiation testing for NASA and improve our understanding of secondary particle environments resulting from the interaction of space radiation with matter.

  19. Testing and analysis on total protein, albumin and A/G of salivary in radiation exposure persons

    International Nuclear Information System (INIS)

    Wang Jun; Zhang Yan; Li Guangwen; Li Gang; Guo Jing; Li Hui; Wang Yuxin; Li Cuixia

    2012-01-01

    Objective: To study the oral health effect of long term low dose radiation on exposure personnel and to provide a basis for further improving the protection ability. Methods: Testing method, which was based on APT and HSA interactions induced by synchronous fluorescence specific changes, and intensity and concentrations of HSA in the solution in the system of synchronous fluorescence showed a good linear relations. the establishment of a APT as a molecular probe was used to test concentration of salivary total protein (TP), albumin (ALB), globulin (GLO) and albumin by synchronous fluorescence spectrum analysis. The information was analyzed in Foxpro 6.0 and SPSS 16.0 software. Result: Protein (TP) Mean Value was 3.904 ±1.369 g/L, Minimum Value was 0.30 g/L and Maximum Value was 7.50 g/L. Albumin (ALB) Mean Value was 0.965±0.665 g/L, Minimum Value was 0.09 g/L and Maximum Value was 3.98 g/L. Globulin (GLO) Mean Value was 2.895±0.947 g/L, Minimum Value was 0.01 g/L and Maximum Value was 5.81 g/L. A/G Mean Value was 0.327. Conclusion: Long term and low dose of radiation would break the chronic physiological balance and concentration of salivary total protein (TP), albumin (ALB), globulin (GLO) and albumin and globulin ratio (A/G) changed obviously. It was necessary to do more special oral health care, further improve the individual protection consciousness, strengthen the radiation monitoring and protection measures, improve the regulation system, and reduce radiation damage on special personnel health significantly. (authors)

  20. Test of the wire ageing induced by radiation for the CMS barrel muon chamber

    CERN Document Server

    Conti, Enrico

    2000-01-01

    We have carried out laboratory test to measure the ageing of a wire tube due to pollutant outgassed by various materials. The tested materials are those used in the muon barrel drift tubes. An X-ray gun irradiated the test tube to accelerate the ageing process. No ageing effect has been measured for a period equivalent to 10 years of operation at LHC.

  1. Analysis of causes of death of population of Altai region settlements exposed to radiation during nuclear test on august 29, 1949 at the Semipalatinsk test site

    International Nuclear Information System (INIS)

    Shoikhet, Ya.N.; Kiselev, V.I.; Algazin, A.I.

    2003-01-01

    An analysis of causes of death of individuals exposed to radiation during nuclear test of 1949 in the effective dose 0.05 - 2.8 Sv was conducted. An increase in spontaneous mortality rate from solid malignant neoplasm in general was detected among individuals exposed at the age of 20 years and more, during the first 29 years of observation with the effective dose 0.5 Sv and higher. The highest excess mortality rates were observed during the first 10 - 29 years with the effective dose 1 Sv. In the same period after the test the excess mortality rates from respiratory organs cancer were detected with the effective dose 0.5 Sv and higher and from digestive organs cancer - with the dose 1 Sv and higher

  2. Radiological protection tests for products which can lead to exposure of the public to ionizing radiation

    International Nuclear Information System (INIS)

    Hill, M.D.; Wrixon, A.D.; Wilkins, B.T.

    1976-07-01

    Testing plays an important role in deciding whether products which irradiate the general public are acceptable from a radiological protection point of view. This report discusses the role which testing should play in decision-making and develops a systematic approach to the testing of products. As an example of this approach, a proposed test programme for ionisation chamber smoke detectors is described. The use of test results as a basis for design specifications and performance requirements in the development of radiological protection standards for products is discussed. A description of the relevant standards is included. (author)

  3. Radiation control monitoring system on the High Temperature Engineering Test Reactor

    International Nuclear Information System (INIS)

    Minowa, Y.; Nakazawa, T.; Sato, K.; Kikuchi, H.; Nomura, T.

    1999-01-01

    Radiation control monitoring system of the HTTR is divided into three subsystems; exhaust monitoring equipment, room air monitoring equipment, dose equivalent rate monitoring equipment. The exhaust monitoring equipment consists of exhaust gas monitors, exhaust dust monitors, and a tritium and carbon sampling device at normal operation of the reactor. Accident gas monitors are also provided for the emergency. The tritium and carbon sampling device uses cupper oxide as a oxidizer, and ethanol amine as a sampling materials which collects continuously tritium and carbon in dust during about one month and is measured by a liquid scintillation counter. The accident gas monitors consist of two channels, for a low and a high range. The high range-gas monitor consists of two ionization chambers: one encloses argon gas and the other encloses xenon gas. Average energy of various gamma-rays, hence, accident exposure dose of the public can be estimated with the comparison of the sensitivity of two kinds of ionization chambers. The dose equivalent rate monitoring equipment consists of silicon semiconductor detectors for gamma-ray, a ionization chamber for gamma-ray, a BF 3 counter for neutron, and accident area monitors which are located in the reactor container. The message of 'check dose !' or 'temporary evacuation !' can be send to the workers in the reactor with a light and a sound. A computer system collects the radiation monitoring data every 10 sec cycle and accumulates them in a server computer. The leakage and the dispersion of helium gas must be taken into account on the radiation control monitoring system of the HTTR. (Suetake, M.)

  4. External radiation in Dolon village due to local fallout from the first USSR atomic bomb test in 1949.

    Science.gov (United States)

    Imanaka, Tetsuji; Fukutani, Satoshi; Yamamoto, Masayoshi; Sakaguchi, Aya; Hoshi, Masaharu

    2006-02-01

    Dolon village, located about 60 km from the border of the Semipalatinsk Nuclear Test Site, is known to be heavily contaminated by local fallout from the first USSR atomic bomb test in 1949. External radiation in Dolon was evaluated based on recent 137Cs data in soil and calculation of temporal change in the fission product composition. After fitting a log-normal distribution to the soil data, a 137Cs deposition of 32 kBq m-2, which corresponds to the 90th-percentile of the distribution, was tentatively chosen as a value to evaluate the radiation situation in 1949. Our calculation indicated that more than 95% of the cumulative dose for 50 y had been delivered within 1 y after the deposition. The resulting cumulative dose for 1 y after the deposition, normalized to the initial contamination containing 1 kBq m-2 of 137Cs, was 15.6 mGy, assuming a fallout arrival time of 3 h and a medium level of fractionation. Finally, 0.50 Gy of absorbed dose in air was derived as our tentative estimate for 1-year cumulative external dose in Dolon due to local fallout from the first USSR test in 1949.

  5. Bread-Board Testing of the Radiation Hard Electron Monitor (RADEM) being developed for the ESA JUICE Mission

    Science.gov (United States)

    Mrigakshi, Alankrita; Hajdas, Wojtek; Marcinkowski, Radoslaw; Xiao, Hualin; Goncalves, Patricia; Pinto, Marco; Pinto, Costa; Marques, Arlindo; Meier, Dirk

    2016-04-01

    The RADEM instrument will serve as the radiation monitor for the JUICE spacecraft. It will characterize the highly dynamic radiation environment of the Jovian system by measuring the energy spectra of energetic electrons and protons up to 40 MeV and 250 MeV, respectively. It will also determine the directionality of 0.3-10 MeV electrons. Further goals include the detection of heavy ions, and the determination of the corresponding LET spectra and dose rates. Here, the tests of the Electron and Proton Telescopes, and the Directionality Detector of the RADEM Bread-Board model are described. The objective of these tests is to validate RADEM design and physical concept applied therein. The tests were performed at various irradiation facilities at the Paul Scherrer Institute (PSI) where energy ranges relevant for space applications can be covered (electrons: ≤100 MeV and protons: ≤230 MeV). The measured values are also compared with GEANT4 Monte-Carlo Simulation results.

  6. Investigation of Doppler spectra of laser radiation scattered inside hand skin during occlusion test

    Science.gov (United States)

    Kozlov, I. O.; Zherebtsov, E. A.; Zherebtsova, A. I.; Dremin, V. V.; Dunaev, A. V.

    2017-11-01

    Laser Doppler flowmetry (LDF) is a method widely used in diagnosis of microcirculation diseases. It is well known that information about frequency distribution of Doppler spectrum of the laser radiation scattered by moving red blood cells (RBC) usually disappears after signal processing procedure. Photocurrent’s spectrum distribution contains valuable diagnostic information about velocity distribution of the RBC. In this research it is proposed to compute the indexes of microcirculation in the sub-ranges of the Doppler spectrum as well as investigate the frequency distribution of the computed indexes.

  7. Spin tests for intermediate states in radiative psi'(3684) decay chains

    International Nuclear Information System (INIS)

    Kabir, P.K.; Hey, A.J.G.

    1976-01-01

    Analysis of the multiple angular-correlation functions for the sequential decays psi'(1 - ) → γ + chi, chi → M anti M, where M is a spinless meson, and psi'(1 - ) → γ 1 + chi, chi → γ 2 + psi, psi (1 - ) → l anti l, when the psi' is formed in e + e - collisions, shows that these can unambiguously distinguish between the spin assignments s/sub chi/ = 0, 1 or 2 for the intermediate states occurring in these decays, as well as determine the multipole amplitudes contributing to the radiative transitions. No dynamical assumptions are made beyond the conservation of angular momentum and parity; recoils are fully taken into account

  8. Design and test of a trial undulator for a compact FEL THz radiation source

    International Nuclear Information System (INIS)

    Xiang Shuhua; Xiong Yongqian; Yang Lei; Liu Xialing; Wei Wei; Chen Jinhua

    2012-01-01

    The undulator is the key component in the THz radiation source based on FEL. We created a trial undulator in order to verify the feasibility of property requirements, and the accumulation of engineering experience. With the use of the finite element calculation software OPERA3D, we modify the structural parameters of the undulator gradually to meet the requirements of the peak, width of the good field and first integration. We also proved that the correction magnet could make the field meet the requirement of the second integration by calculation. After fabrication and acceptance, the electron trajectory is calculated based on the measured field. (authors)

  9. Testing of Sapphire Optical Fiber and Sensors in Intense Radiation Fields When Subjected to Very High Temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Blue, Thomas [The Ohio State Univ., Columbus, OH (United States); Windl, Wolfgang [The Ohio State Univ., Columbus, OH (United States)

    2017-12-15

    The primary objective of this project was to determine the optical attenuation and signal degradation of sapphire optical fibers & sensors (temperature & strain), in-situ, operating at temperatures up to 1500°C during reactor irradiation through experiments and modeling. The results will determine the feasibility of extending sapphire optical fiber-based instrumentation to extremely high temperature radiation environments. This research will pave the way for future testing of sapphire optical fibers and fiber-based sensors under conditions expected in advanced high temperature reactors.

  10. A full-text english database of testimonies of those exposed to radiation near the Semipalatinsk nuclear test site, Kazakhstan

    OpenAIRE

    Matsuo, Masatsugu; Kawano, Noriyuki; Hirabayashi, Kyoko; Tooka, Yasuyuki; Apsalikov, Kazbek Negamatovich; Hoshi, Masaharu

    2004-01-01

    The present paper is a sequel to the initial report (Kawano et al 2003a) of the project for a full-text Japanese database of the testimonies of those exposed to radiation near the nuclear test site of Semipalatinsk, Kazakhstan. 139 testimonies were gathered in four villages near Semipalatinsk in 2002. We translated them into English from Russian and Kazakh, and created a full-text database by using a Latin script text retrieval program, TERESA. The present paper attempts at essentially the sa...

  11. Test of the wire ageing induced by radiation for the CMS barrel muon chambers

    CERN Document Server

    Conti, E

    2001-01-01

    We have carried out laboratory tests to measure the ageing of a wire tube due to pollutants outgassed by various materials. The tested materials are those used in the barrel muon drift tubes of the CMS experiment at LHC. An X-ray gun irradiated the test tube to accelerate the ageing process. No ageing effect has been measured for a period equivalent to 10 years of operation at LHC. (15 refs).

  12. X-ray Emitting GHz-Peaked Spectrum Galaxies: Testing a Dynamical-Radiative Model with Broad-Band Spectra

    International Nuclear Information System (INIS)

    Ostorero, L.; Moderski, R.; Stawarz, L.; Diaferio, A.; Kowalska, I.; Cheung, C.C.; Kataoka, J.; Begelman, M.C.; Wagner, S.J.

    2010-01-01

    In a dynamical-radiative model we recently developed to describe the physics of compact, GHz-Peaked-Spectrum (GPS) sources, the relativistic jets propagate across the inner, kpc-sized region of the host galaxy, while the electron population of the expanding lobes evolves and emits synchrotron and inverse-Compton (IC) radiation. Interstellar-medium gas clouds engulfed by the expanding lobes, and photoionized by the active nucleus, are responsible for the radio spectral turnover through free-free absorption (FFA) of the synchrotron photons. The model provides a description of the evolution of the GPS spectral energy distribution (SED) with the source expansion, predicting significant and complex high-energy emission, from the X-ray to the γ-ray frequency domain. Here, we test this model with the broad-band SEDs of a sample of eleven X-ray emitting GPS galaxies with Compact-Symmetric-Object (CSO) morphology, and show that: (i) the shape of the radio continuum at frequencies lower than the spectral turnover is indeed well accounted for by the FFA mechanism; (ii) the observed X-ray spectra can be interpreted as non-thermal radiation produced via IC scattering of the local radiation fields off the lobe particles, providing a viable alternative to the thermal, accretion-disk dominated scenario. We also show that the relation between the hydrogen column densities derived from the X-ray (N H ) and radio (N HI ) data of the sources is suggestive of a positive correlation, which, if confirmed by future observations, would provide further support to our scenario of high-energy emitting lobes.

  13. Project W-151 flexible receiver radiation detector system acceptance test plan. Revision 1

    International Nuclear Information System (INIS)

    Troyer, G.L.

    1994-01-01

    The attached document is the Acceptance Test Plan for the portion of Project W-151 dealing with acceptance of gamma-ray detectors and associated electronics manufactured at the Idaho National Engineering Laboratory (INEL). The document provides a written basis for testing the detector system, which will take place in the 305 building (300 Area)

  14. Poisson goodness-of-fit tests for radiation-induced chromosome aberrations

    International Nuclear Information System (INIS)

    Merkle, W.

    1981-01-01

    Asymptotic and exact Poisson goodness-to-fit tests have been reviewed with regard to their applicability in analysing distributional properties of data on chromosome aberrations. It has been demonstrated that for typical cytogenetic samples, i.e. when the average number of aberrations per cell is smaller than one, results of asymptotic tests, especially of the most commonly used u-test, differ greatly from results of corresponding exact tests. While the u-statistic can serve as a qualitative index to indicate a tendency towards under- or over-dispersion, exact tests should be used if the assumption of a Poisson distribution is crucial, e.g. in investigating induction mechanisms. If the main interest is to detect a difference between the mean and the variance of a sample it is furthermore important to realize that a much larger sample size is required to detect underdispersion than it is to detect overdispersion. (author)

  15. Construction of computational program of aging in insulating materials for searching reversed sequential test conditions to give damage equivalent to simultaneous exposure of heat and radiation

    International Nuclear Information System (INIS)

    Fuse, Norikazu; Homma, Hiroya; Okamoto, Tatsuki

    2013-01-01

    Two consecutive numerical calculations on degradation of polymeric insulations under thermal and radiation environment are carried out to simulate so-called reversal sequential acceleration test. The aim of the calculation is to search testing conditions which provide material damage equivalent to the case of simultaneous exposure of heat and radiation. At least following four parameters are needed to be considered in the sequential method; dose rate and exposure time in radiation, as well as temperature and aging time in heating. The present paper discusses the handling of these parameters and shows some trial calculation results. (author)

  16. The Lemna minor growth inhibition test as basis to evaluate radiation or radionuclide-induced effects on freshwater plants

    Energy Technology Data Exchange (ETDEWEB)

    Horemans, N.; Van Hees, M.; Van Hoeck, A.; Vandenhove, H. [Belgian Nuclear Research Centre, SCK.CEN, Boeretang 200, 2400 Mol (Belgium)

    2014-07-01

    The setting of radiation protection criteria for wildlife is based on tiered Environmental Risk Assessments (ERA) methods. At various points in such a tiered ERA robust and transparent benchmark values are needed to indicate the levels of exposure that are considered safe to the environment. Although not ideal these benchmark values are today mainly based on laboratory-based experiments in which the toxic effects of radiation or radionuclides to one selected species exposed under standardised growth conditions is studied. As such an eco-toxicity test has been developed for the floating macrophyte Lemna minor that can be used to test the effect of different chemicals in freshwater. Here the use of this test to estimate effects of radiation or radionuclides and its relevance to the environment will be discussed. First single dose response curves are shown that were set up according to the guidelines for gamma, uranium and as a reference also cadmium. According to the guidelines growth inhibition can be calculated on different endpoints like frond number and frond area. The choice of this endpoint seems to be of major importance as dependent on the stressor significant shifts in the EC50 values, the concentration giving 50% effect, were observed. For gamma radiation a recovery experiment was set up in irradiated plants were allowed to grow again for 7 days in control conditions. It was shown that plant growth rate did not catch up with that of the non-irradiated group. On the contrary, plant cultures that showed a growth inhibition above 40% immediately after irradiation completely collapsed during the recovery period indicating no recovery from the gamma induced damage and resulting in a 3-fold lower EC50 value after 7 days recovery. The relevance of these data to the environment will be further discussed. Finally the influence of different cations on the uranium speciation and toxicity are studied. These experiments are the first steps to set up a biotic ligand

  17. Tests in breeding of caladium, banana and papaya by utilization of radiation

    International Nuclear Information System (INIS)

    Suda, Hirokatsu; Matsubara, Hisao; Hashimoto, Tomoaki; Kawano, Shin.

    1984-01-01

    In the Bonin Islands, the horticulture of subtropical plants including caladium is active. For the plant to be taken home by tourists, however, its height reaching 50 cm is too large. To make it smaller, its deformation by the mutation utilizing radiation has been carried out. For the purpose of breeding, the irradiation of its bulbs with cobalt-60 γ-ray up to 30 Gy is suitable. By the irradiation, the height becomes 1/3 - 1/5 of that of the unirradiated one, the length of its leaves 1/3 - 1/4 and the width 1/2 - 1/4. The mutation appears also in the plants as irradiated, but the stabilized mutation due to irradiation appears mostly in the next year or later. (Mori, K.)

  18. Ribbons on the Cosmic Background Radiation Sky: A Powerful Test of a Baryon Symmetric Universe

    International Nuclear Information System (INIS)

    Kinney, W.H.; Kolb, E.W.; Turner, M.S.; Kolb, E.W.; Turner, M.S.; Turner, M.S.

    1997-01-01

    If the Universe consists of domains of matter and antimatter, annihilations at domain interfaces leave a distinctive imprint on the cosmic background radiation (CBR) sky. The signature is anisotropies in the form of long, thin ribbons of width θ W ∼0.1 circ , separated by angle θ L ≅1 circ (L/100h -1 Mpc) (L is the characteristic domain size) and with distortion parameter y∼10 -6 . Such a pattern could potentially be detected by the high-resolution CBR anisotropy experiments planned for the next decade, and such experiments may finally settle the question of whether or not our Hubble volume is baryon symmetric. copyright 1997 The American Physical Society

  19. Possibility of experiments using radiation counters for test electron stability and Pauli principle violation in atoms

    International Nuclear Information System (INIS)

    Barabash, A.S.

    1989-01-01

    Capabilities of modern radiation detectors for investigation into electron stability and possible violation of Pauli principle in atoms are discussed. For experimental searches of electron instability the following low-background devices are used: scintillation NaI-detectors, semiconducting detectors of enriched germanium, emission chamber, multisection proportional counter and low-temperature detectors. It is ascertained that using modern low-background devices applying the earlier enumerated detectors, it is possible to achieve sensitivity of the order of 10 24 -10 25 years for the electron lifetime relatively to its decay and Pauli principle violation in atoms. Experiments with sensitivity of ∼ 10 26 -10 27 can be realized in massive low-temperature detectors, developed for neutrino physics. 28 refs; 1 fig

  20. Synchrotron radiation microimaging in rabbit models of cancer for preclinical testing

    Energy Technology Data Exchange (ETDEWEB)

    Umetani, Keiji [Japan Synchrotron Radiation Research Institute, SPring-8, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan)], E-mail: umetani@spring8.or.jp; Uesugi, Kentaro [Japan Synchrotron Radiation Research Institute, SPring-8, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Kobatake, Makito; Yamamoto, Akira; Yamashita, Takenori; Imai, Shigeki [Kawasaki Medical School, Matsushima, Kurashiki-shi, Okayama 701-0192 (Japan)

    2009-10-01

    Preclinical laboratory animal imaging modalities such as microangiography and micro-computed tomography (micro-CT) have been developed at the SPring-8 BL20B2 bending magnet beamline. The objective of this paper is to demonstrate the usefulness of microangiography systems for physiological examinations of live animals and micro-CT systems for postmortem morphological examinations. Synchrotron radiation microangiography and micro-CT with contrast agents present the main advantageous capability of depicting the anatomy of small blood vessels with tens of micrometers' diameter. This paper reports two imaging instrument types and their respective applications to preclinical imaging of tumor angiogenic blood vessels in tumor-bearing rabbits, where tumor angiogenesis is characterized morphologically by an increased number of blood vessels. A microangiography system with spatial resolution around 10 {mu}m has been used for therapeutically evaluating angiogenic vessels in a rabbit model of cancer for evaluating embolization materials in transcatheter arterial embolization and for radiation therapy. After an iodine contrast agent was injected into an artery, in vivo imaging was carried out using a high-resolution real-time detector incorporating an X-ray direct-conversion-type SATICON pickup tube. On the other hand, a micro-CT system capably performed three-dimensional visualization of tumor angiogenic blood vessels using tumor-transplanted rabbit specimens with a barium sulfate contrast agent injected into the blood vessels. For specimen imaging, a large-field high-resolution micro-CT system based on a 10-megapixel CCD camera was developed to study tumor-associated alterations in angioarchitecture. Evidence of increased vascularity by tumor angiogenesis and decreased vascularity by tumor treatments was achieved by physiological evaluation of angiogenic small blood vessels in microangiographic imaging and by morphological assessment in micro-CT imaging. These results

  1. Synchrotron radiation microimaging in rabbit models of cancer for preclinical testing

    International Nuclear Information System (INIS)

    Umetani, Keiji; Uesugi, Kentaro; Kobatake, Makito; Yamamoto, Akira; Yamashita, Takenori; Imai, Shigeki

    2009-01-01

    Preclinical laboratory animal imaging modalities such as microangiography and micro-computed tomography (micro-CT) have been developed at the SPring-8 BL20B2 bending magnet beamline. The objective of this paper is to demonstrate the usefulness of microangiography systems for physiological examinations of live animals and micro-CT systems for postmortem morphological examinations. Synchrotron radiation microangiography and micro-CT with contrast agents present the main advantageous capability of depicting the anatomy of small blood vessels with tens of micrometers' diameter. This paper reports two imaging instrument types and their respective applications to preclinical imaging of tumor angiogenic blood vessels in tumor-bearing rabbits, where tumor angiogenesis is characterized morphologically by an increased number of blood vessels. A microangiography system with spatial resolution around 10 μm has been used for therapeutically evaluating angiogenic vessels in a rabbit model of cancer for evaluating embolization materials in transcatheter arterial embolization and for radiation therapy. After an iodine contrast agent was injected into an artery, in vivo imaging was carried out using a high-resolution real-time detector incorporating an X-ray direct-conversion-type SATICON pickup tube. On the other hand, a micro-CT system capably performed three-dimensional visualization of tumor angiogenic blood vessels using tumor-transplanted rabbit specimens with a barium sulfate contrast agent injected into the blood vessels. For specimen imaging, a large-field high-resolution micro-CT system based on a 10-megapixel CCD camera was developed to study tumor-associated alterations in angioarchitecture. Evidence of increased vascularity by tumor angiogenesis and decreased vascularity by tumor treatments was achieved by physiological evaluation of angiogenic small blood vessels in microangiographic imaging and by morphological assessment in micro-CT imaging. These results

  2. Off-site environmental monitoring report: radiation monitoring around United States nuclear test areas, calendar year 1984

    International Nuclear Information System (INIS)

    Potter, G.D.; Black, S.C.; Grossman, R.F.; Patzer, R.G.; Smith, D.D.

    1985-04-01

    This report covers the routine radiation monitoring activities conducted by the Environmental Monitoring Systems Laboratory-Las Vegas in areas which may be affected by nuclear testing programs of the Department of Energy. This monitoring is conducted to document compliance with standards, to identify trends in environmental radiation, and to provide such information to the public. It summarizes these activities for calendar year 1984. No radioactivity attributable to NTS activities was detectable offsite by the monitoring networks. Using recorded wind data and Pasquill stability categories, atmospheric dispersion calculations based on reported radionuclides releases yield an estimated dose of 1 x 10 -3 person-rem to the population within 80 km of the Nevada Test Site during 1983. World-wide fallout of Kr-85, Sr-90, Cs-137, and Pu-239 detected by the monitoring networks would cause maximum exposure to an individual of less than 0.6 mrem per year. Plutonium in air was still detectable along with krypton-85, which continued its gradual increase, as has been reported previously. Cesium and strontium in air were near their detection limits. An occasional net exposure to offsite residents has been detected by the TLD network. On investigation, the cause of such net exposures has been due to personal habits or occupational activities, not to NTS activities. 32 refs., 36 figs., 27 tabs

  3. Development of a test device to characterize thermal protective performance of fabrics against hot steam and thermal radiation

    International Nuclear Information System (INIS)

    Su, Yun; Li, Jun

    2016-01-01

    Steam burns severely threaten the life of firefighters in the course of their fire-ground activities. The aim of this paper was to characterize thermal protective performance of flame-retardant fabrics exposed to hot steam and low-level thermal radiation. An improved testing apparatus based on ASTM F2731-11 was developed in order to simulate the routine fire-ground conditions by controlling steam pressure, flow rate and temperature of steam box. The thermal protective performance of single-layer and multi-layer fabric system with/without an air gap was studied based on the calibrated tester. It was indicated that the new testing apparatus effectively evaluated thermal properties of fabric in hot steam and thermal radiation. Hot steam significantly exacerbated the skin burn injuries while the condensed water on the skin’s surface contributed to cool down the skin tissues during the cooling. Also, the absorbed thermal energy during the exposure and the cooling was mainly determined by the fabric’s configuration, the air gap size, the exposure time and the existence of hot steam. The research provides a effective method to characterize the thermal protection of fabric in complex conditions, which will help in optimization of thermal protection performance of clothing and reduction of steam burn. (paper)

  4. Genetic effects of radiation and prediction of hereditary pathology of population of areas around the former Semipalatinsk test site

    International Nuclear Information System (INIS)

    Bigaliev, A.B.

    1998-01-01

    Epidemiological analysis of diseases and mortality of the population living in areas around Semipalatinsk test site is not only theoretically interesting in terms of the human being genetics, but is important for the health-care in practice, since it allows correct planning the score of medical social aid to the sick people and their families, including measures. Assessment of posterior consequences of low dose radiation effect on health of the population of the areas around the former Semipalatinsk nuclear test site is of special interest. Many underground, atmospheric and above-ground tests of nuclear weapon resulted in a significant increase of the oncologic and blood diseases rate among several generations of the effected people. Moreover, consequences of the above-ground and atmospheric tests of nuclear and hydrogen weapon will show up in the next century, taking into account the fact that the 'open' tests were ceased only at the middle of 60-th. The birth rate of children with the inherent intelligence defects was determined according to the accounting records of the new-born children within 1986-1992 years. Analysis of perinatal mortality was carried out based on the records on autopsy within 1985-1992 years. The two-fold increase of the onco diseases rate was revealed among children. The rate of spontaneous aborts in the Eginbulak district was 9.99% and exceeded the average rate in the region and indexes of other regions

  5. Pollen tube growth test (PTGT) in environmental biomonitoring and predictive radiation biology studies: problem and prospect

    International Nuclear Information System (INIS)

    Pandey, Devi D.

    2012-01-01

    In Environmental and Human Bio monitoring studies of Hazardous xenobiotics over living system particularly at cell level, it is desirable to have easy and sensitive test system like Cell Viability assay, MNT, Cell Culture photo toxicity Test, PTGT etc. Out of these the PTGT quite better than other because the in vitro culture of pollen grain can provides a sensitive indication of toxicity at cellular level, since germination and growth of pollen tube will inhibited in presence of toxic substance like DDT, Heavy metal, even Radionuclide's. This test system is easy, economical and widely accepted through out world. In PTGT pollen tube never containing Chloroplast or other plastids so pollen tube resembles animals more than a plant organ and is therefore also a suitable as model for Genotoxicity Assessment of compounds harmful to animal and humans. Lack of plastids in PT, PTGT will not identify the toxic effect of compounds that targets Non cyclic and cyclic photoposphorylation of photosynthesis. This test system valid in International Toxicity Testing Protocol. But this method is time consuming and problem in measurement of pollen tube growing in a culture medium became usually bent and make measurement difficult. Other disadvantage of this method is requirement of DMSO to dissolve test substance of low water suitability in culture medium. DMSO shown to have no effect on PTG at Concentration not more than 1% but some extent interfere with results. Values of PTG are quantified in ED50/IC50 that is the concentration of test compounds that reduces pollen tube growth to 50% of control. So PTGT could be very sensitive and easy to assess in common lab in International way. (author)

  6. Efficacy Test of Mutant Metarrhizium anisopliae by Gamma Radiation to Control Rhinoceros Beetle (Oryctes rhinoceros)

    International Nuclear Information System (INIS)

    Jeerapong, Lawan; Piadang, Nattayana; Jantasang, Kittisak; Kamontip, Rukprasong

    2006-09-01

    Increasing the efficiency of Metarhizium anisopliae (Ma) DOAE variety to control rhinoceros beetle (Oryctes rhinoceros) by gamma radiation was found that among 20 varieties got from the fungus irradiated with 20 doses of gamma radiation, MAI-20 irradiated with 1.6, 8 and 10 kGy of gamma ray was the most suitable far control rhinoceros larvae as follow reason : the dominant characterize of MAI -20 is the spore with black color, It can grow wi trh the diameter of 1.8 centimeter on PDA agar within 10 days and full growth on surface of maize seed at 1.5 kilogram with in 15 days. The effectiveness of MAI-20 to control 3 in star larvae of rhinoceros beetle was 80 percent mortality within 10 days while the original variety (DOAE variety) with the dominant characterization of green color spore, 1 centimeter diameter growth on PDA agar within 10 days and full growth on surface of maize seed 1.5 kilogram within 15 days. This variety caused 60 percent mortality to 3 in star larvae of rhinoceros within 7 days. It could conclude that from laboratory experiment, MAI-20 is the most effective and suitable variety to control rhinoceros beetle even though the mortality time was longer than the original variety because the larvae of the insect does not caused the damage to coconut. The efficiency for controlling rhinoceros beetle at field trial by using irradiated MAI-20 comparing to the original variety and control (with out fungus) by adding each 1,2 kilogram of the MAI-20 and original variety growth on surface of maize seed on each manure pile size 1x1x0.5 meter. After 7 days of both varieties of Metarhizium application, the number of dead larvae caused by the fungus and the number of healthy larvae in each manure pile was collected and counted. It was found that after continuous survey 4 time (7 day per 1 time ) the percent mortality of rhinoceros larvae caused by the 2 fungus varieties were as follow : 1 kilogram of original varieties had an average of 55.5 percent larva

  7. Real-time and on-site γ-ray radiation response testing system for semiconductor devices and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Mu, Yifei, E-mail: Y.Mu@student.liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Zhao, Ce Zhou, E-mail: cezhou.zhao@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Qi, Yanfei, E-mail: yanfei.qi01@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Lam, Sang, E-mail: s.lam@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Zhao, Chun, E-mail: garyzhao@ust.hk [Nano and Advanced Materials Institute, Hong Kong University of Science and Technology, Kowloon (Hong Kong); Lu, Qifeng, E-mail: qifeng@liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Cai, Yutao, E-mail: yutao.cai@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Mitrovic, Ivona Z., E-mail: ivona@liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Taylor, Stephen, E-mail: s.taylor@liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Chalker, Paul R., E-mail: pchalker@liverpool.ac.uk [Center for Materials and Structures, School of Engineering, University of Liverpool, Liverpool L69 3GH (United Kingdom)

    2016-04-01

    The construction of a turnkey real-time and on-site radiation response testing system for semiconductor devices is reported. Components of an on-site radiation response probe station, which contains a 1.11 GBq Cs{sup 137} gamma (γ)-ray source, and equipment of a real-time measurement system are described in detail for the construction of the whole system. The real-time measurement system includes a conventional capacitance–voltage (C–V) and stress module, a pulse C–V and stress module, a conventional current–voltage (I–V) and stress module, a pulse I–V and stress module, a DC on-the-fly (OTF) module and a pulse OTF module. Electrical characteristics of MOS capacitors or MOSFET devices are measured by each module integrated in the probe station under continuous γ-ray exposure and the measurement results are presented. The dose rates of different gate dielectrics are calculated by a novel calculation model based on the Cs{sup 137} γ-ray source placed in the probe station. For the sake of operators’ safety, an equivalent dose rate of 70 nSv/h at a given operation distance is indicated by a dose attenuation model in the experimental environment. HfO{sub 2} thin films formed by atomic layer deposition are employed to investigate the radiation response of the high-κ material by using the conventional C–V and pulse C–V modules. The irradiation exposure of the sample is carried out with a dose rate of 0.175 rad/s and ±1 V bias in the radiation response testing system. Analysis of flat-band voltage shifts (ΔV{sub FB}) of the MOS capacitors suggests that the on-site and real-time/pulse measurements detect more serious degradation of the HfO{sub 2} thin films compared with the off-site irradiation and conventional measurement techniques.

  8. Emulating Dynamic Radio Channels for Radiated Testing of Massive MIMO Devices

    DEFF Research Database (Denmark)

    Kyösti, Pekka; Hentilä, Lassi; Kyröläinen, Jukka

    2018-01-01

    This paper discusses a multi-probe anechoic chamber based (MPAC) setup, capable of reconstructing non-stationary radio propagation environments for testing of mm-wave and massive MIMO devices. The test setup is aimed for evaluation of end to end performance of devices, including hybrid beamforming...... operations of antenna arrays and base band processing, in highly time variant channel conditions. In this work we present simulated comparison of an ideal reference radio channel model and corresponding model implemented with limited resources of MPAC components. We give a qualitative analysis of the results...... with non-line of sight (NLOS) channel models, without quantitative evaluation. The example device under test (DUT) is a 8x8 planar array with half wavelength inter-element spacing....

  9. Measurements of integrated components' parameters versus irradiation doses gamma radiation (60Co) dosimetry-methodology-tests

    International Nuclear Information System (INIS)

    Fuan, J.

    1991-01-01

    This paper describes the methodology used for the irradiation of the integrated components and the measurements of their parameters, using Quality Insurance of dosimetry: - Measurement of the integrated dose using the competences of the Laboratoire Central des Industries Electriques (LCIE): - Measurement of irradiation dose versus source/component distance, using a calibrated equipment. - Use of ALANINE dosimeters, placed on the support of the irradiated components. - Assembly and polarization of components during the irradiations. Selection of the irradiator. - Measurement of the irradiated components's parameters, using the competences of the societies: - GenRad: GR130 tests equipement placed in the DEIN/SIR-CEN SACLAY. - Laboratoire Central des Industries Electriques (LCIE): GR125 tests equipment and this associated programmes test [fr

  10. Test CMOS/SOS RAM for transient radiation upset comparative research and failure analysis

    International Nuclear Information System (INIS)

    Nikiforov, A.Y.; Poljakov, I.V.

    1995-01-01

    The test Complementary Metal-Oxide-Semiconductor/Silicon-on-Sapphire Random Access Memory (CMOS/SOS RAM) with eight types of memory cells was designed and tested at high dose rates with a flash X-ray machine and laser simulator. The memory cell (MC) design with additional transistors and RC-chain was found to be upset free up to 2 x 10 12 rad(Si)/s. An inversion effect was discovered in which almost 100% logic upset was observed in poorly protected memory cell arrays at very high dose rates

  11. Radiation tests of photodiodes for the ATLAS SCT and PIXEL opto- links

    CERN Document Server

    Hou, L S; Lee, S C; Su, D S; Teng, P K

    2005-01-01

    In previous research, epitaxial Si PIN photodiodes produced by Centronic which will be used in the ATLAS semiconductor tracker have been irradiated with 1 MeV neutrons and 24 GeV protons with fluences up to an equivalent of $10^{15}$ 1 MeV neutrons (1,2) . In this work 30 MeV proton beams were used to irradiate Centronic and Truelight epitaxial Si PIN diodes with accumulated fluences of up to 2.1 multiplied by $10^{14}$-30 MeV p $cm^{-2}$, an equivalent of 5.7 multiplied by $10^{14} cm^{-2}$ 1 MeV neutrons, to reach the pixel radiation environment. The responsivity was measured with different levels of fluence in order to study the responsivity behaviour of two different types of photodiodes. The responsivity behaviour of these two photodiodes was similar: a linear degradation at large fluences, greater than $10^{14}$ 30 MeV p $cm^{-2}$, but with different slopes. The response of the Centronic PIN diode showed a degradation to 73% after a proton fluence of $10^{13}$ p $cm^{-2}$ of 30 MeV and a linear degradat...

  12. Design and testing of indigenous cost effective three dimensional radiation field analyser (3D RFA).

    Science.gov (United States)

    Ganesh, K M; Pichandi, A; Nehru, R M; Ravikumar, M

    2014-06-01

    The aim of the study is to design and validate an indigenous three dimensional Radiation Field Analyser (3D RFA). The feed system made for X, Y and Z axis movements is of lead screw with deep ball bearing mechanism made up of stain less steel driven by stepper motors with accuracy less than 0.5 mm. The telescopic column lifting unit was designed using linear actuation technology for lifting the water phantom. The acrylic phantom with dimensions of 800 x 750 x 570 mm was made with thickness of 15 mm. The software was developed in visual basic programming language, classified into two types, viz. beam analyzer software and beam acquisition software. The premeasurement checks were performed as per TG 106 recommendations. The physical parameters of photon PDDs such as Dmax, D10, D20 and Quality Index (QI), and the electron PDDs such as R50, Rp, E0, Epo and X-ray contamination values can be obtained instantaneously by using the developed RFA system. Also the results for profile data such as field size, central axis deviation, penumbra, flatness and symmetry calculated according to various protocols can be obtained for both photon and electron beams. The result of PDDs for photon beams were compared with BJR25 supplement values and the profile data were compared with TG 40 recommendation. The results were in agreement with standard protocols.

  13. Simulation and Performance Test Technology Development for Semiconductor Radiation Detection Instrument Fabrication

    International Nuclear Information System (INIS)

    Kim, Jong Kyung; Lee, W. G.; Kim, S. Y.; Shin, C. H.; Kim, K. O.; Park, J. M.; Jang, D. Y.; Kang, J. S.

    2010-06-01

    - Analysis on the Absorbed Dose and Electron Generation by Using MCNPX Code - Analysis on the Change of Measured Energy Spectrum As a Function of Bias Voltage Applied in Semiconductor Detector - Comparison of Monte Carlo Simulation Considering the Charge Collection Efficiency and Experimental Result - Development of Semiconductor Sensor Design Code Based on the Graphic User Interface - Analysis on Depth Profile of Ion-implanted Semiconductor Wafer Surface and Naturally Generated SiO2 Insulation Layer Using Auger Electron Spectroscopy - Measurement of AFM Images and Roughness to Abalyze Surface of Semiconductor Wafer with respect to Annealing and Cleaning Process - Measurement of Physical Properties for Semiconductor Detector Surface after CZT Passivation Process - Evaluation of Crystal Structure and Specific Resistance of CZT - Measurement/Analysis on Band Structure of CZT Crystal - Evaluation of Neutron Convertor Layer with respect to Change in Temperature - Measurement/Evaluation of physical characteristics for lattice parameter, specific resistance, and band structure of CZT crystal - Measurement/Evaluation of lattice transition of SiC semiconductor detector after radiation irradiation - Measurement/Evaluation of performance of semiconductor detector with respect to exposure in high temperature environment

  14. Test and further development of a silicon picsel detector for detecting ionising radiation

    International Nuclear Information System (INIS)

    Lechner, P.

    1990-12-01

    The concept of a silicon detector with a MOSFET as an integrating amplification element (DEP-MOSFET) is introduced. The method of functioning of different version and a picture cell (picsel) detector, which makes energy and location resolution possible, is discussed. Quantitative relationships which describe the operation of the component as a detector, and quantitative relationships for the energy resolution of a DEP-MOSFET are derived theoretically. Measurements provide the proof of the detection function of different versions and the confirmation of the results of the theoretical model. The excellent noise properties of DEP-MOSFET detectors with closed structure are pointed out. The further development of the explained detector concept by integration of a JFET as the amplifying element (here introduced in the form of a computer simulation and quantitative relationships which describe the behaviour as a detector) promises progress with regard to energy resolution and radiation resistance, and offers the possibility of producing a picsel detector made from closed structures with little technological effort. (orig.) [de

  15. Radiation technique in density and strength testing of coniferous structural timber

    International Nuclear Information System (INIS)

    Dzbenski, W.; Krzosek, S.

    1998-01-01

    The control process of intermediate and final wood products manufacturing is more and more frequently assisted by flow detectors. In radiation devices cesium isotope 137 Cs is replaced by less harmful americium 241 Am. Americium 241 Am was used in the measuring device made in The Academy of Mining and Metallurgy in Cracow. The device was applied in Warsaw Agricultural University (SGGW) in research on Polish structural timber. Negative influence of anatomical defects (knots, compression wood, resinasis, slope of grain, decay) was estimated by gammascopy method. Botanical species (pine, spruce), position in a stem (sapwood, heartwood), anatomical direction (radial, tangential) and moisture content were taken into account. The method of determination a critical place in timber were density is the lowest value (what is an obligatory criterion of stress graded structural timber according to EN standards) was developed. The practical implementation of the method can be reached when sawmills producing structural timber (especially for export) will be more interested in using miniaturized isotope densitometers. (author)

  16. Manufacture research of the test equipment to measure the dose rate in high radiation medium

    International Nuclear Information System (INIS)

    Phan Luong Tuan; Nguyen Van Sy; Nguyen Xuan Vinh; Dang Quang Bao; Nguyen Thanh Hung; Pham Minh Duc; Nguyen Xuan Truong

    2017-01-01

    Photodiode BPW34 is operated as a low voltage counter tubes. When the radiation rays go into the BPW34,they will create a pairs of electron and hole. If setting the reverse bias in to the BPW34, a pulse is achieved and it can be amplified and processed. The STM32 is the microcontroller family which is developed base on ARM processors. The STM32 incorporated many new features such as ADC, I2C, etc. With the connectional ability to other devices, the STM32 is proving its advantages in the development of equipment.The application of irradiation technology in the economy-society increases widespread as food irradiation, mutant irradiation, etc. Until now the calculation the high dose rate at Hanoi Irradiation Center is identified by the Fricke, ECB dosimeters. The dosimeters must be destroyed in order to serve for dose rate determination. Manufacture research the equipment for dose rate calculation support to determine dose rate directly through the equipment’s signal and this equipment can be used multiple. This equipment can be connected to other devices to control the irradiation process better via signals. (author)

  17. Guide for preparing annual reports on radiation-safety testing of electronic products (general)

    International Nuclear Information System (INIS)

    1987-10-01

    For manufacturers of electronic products other than those for which a specific guide has been issued, the guide replaces the Guide for the Filing of Annual Reports (21 CFR Subchapter J, Section 1002.11), HHS Publication FDA 82-8127. The electronic product (general) annual reporting guide is applicable to the following products: products intended to produce x radiation (accelerators, analytical devices, therapy x-ray machines); microwave diathermy machines; cold-cathode discharge tubes; and vacuum switches and tubes operating at or above 15,000 volts. To carry out its responsibilities under Public Law 90-602, the Food and Drug Administration's Center for Devices and Radiological Health (CDRH) has issued a series of regulations contained in Title 21 of the Code of Federal Regulations (CFR). Part 1002 of 21 CFR deals with records and reports. Section 1002.61 categorizes electronic products into Groups A through C. Section 1002.30 requires manufacturers of products in Groups B and C to establish and maintain certain records, while Section 1002.11 requires such manufacturers to submit an Annual Report summarizing the contents of the required records. Section 1002.7 requires that reports conform to reporting guides issued by CDRH unless an acceptable justification for an alternate format is provided

  18. Production and testing of a synthetic diamond film radiation dosimeter for radiotherapy

    CERN Document Server

    Fidanzio, A; Venanzi, C; Pinzari, F; Piermattei, A

    2002-01-01

    A detector, constituted by a polycrystalline chemical vapor deposited diamond film, has been made for on-line radiotherapy beam analysis in terms of dose distributions in water equivalent material. Preliminary results are reported which evidence that the leakage current can be a limiting parameter for an efficient collection of the charge carriers produced by the ionizing radiation. A signal to noise ratio near to 100 has been obtained. A priming effect similar to that found in natural diamond devices has also been evidenced, and a stable detector response was obtained after an accumulated dose of 5 Gy. The linearity has been achieved between the detector reading and the dose. The detector sensitivity resulted was equal to 77 nC/Gy per mm sup 3 of detector sensitive volume. A power law with exponent DELTA less than one has been found between detector reading and dose rate. However, when the dose rate dependence was corrected, the percentage depth doses, along an X-ray beam central axis, was in agreement with ...

  19. Low-intensive proton generators for radiation testing; Nizkointensivnyj protonnyj generator dlya radiatsionnykh ispytanij

    Energy Technology Data Exchange (ETDEWEB)

    Istomin, I V; Gurbich, A F; Semenov, A V

    1994-12-31

    Experiment is conducted and calculations are performed grounding the possibility of creating a low-intensity proton generator based on nuclear reaction. The necessity in such a proton source is defined by the need of conducting long-term testings and by the absence of appropriate equipment.

  20. British Nuclear Test Veterans' Association. Radiation exposure and subsequent health history of veterans and their children

    International Nuclear Information System (INIS)

    Urquhart, J.

    1993-01-01

    The present study of veterans' health carried out in association with Tyne Tees Television presents new and disturbing evidence of significant health effects in both veterans and their children, based on the health records of 1,454 members of the British Nuclear Test Veterans' Association, of whom 1,147 were fathers. (orig./MG)

  1. Assaying the Mutagenic Potential of ELF Radiation through Reverse Mutagenesis via the Ames Test

    National Research Council Canada - National Science Library

    Moga, Paul

    1996-01-01

    ...) on certain strains of Salmonella typhimurium. The strain of S-typhimurium used in the Ames test has a mutation on one gene of the histidine operon which prevents it from growing and replicating without the presence of histidine in the media...

  2. Radiation Testing Electronics with Heavy Ions-The Best Way to Hit a Target Moving Ever Exponentially Faster

    Science.gov (United States)

    Ladbury, Ray

    2018-01-01

    In 1972, when engineers at Hughes Aircraft Corporation discovered that errors in their satellite avionics were being caused by cosmic rays (so-called single-event effects, or SEE), Moore's Law was only 7 years old. Now, more than 45 years on, the scaling that drove Moore's Law for its first 35 years has reached its limits. However, electronics technology continues to evolve exponentially and SEE remain a formidable issue for use of electronics in space. SEE occur when a single ionizing particle passes through a sensitive volume in an active semiconductor device and generates sufficient charge to cause anomalous behavior or failure in the device. Because SEE can occur at any time during the mission, the emphasis of SEE risk management methodologies is ensuring that all SEE modes in a device under test are detected by the test. Because a particle's probability of causing an SEE generally increases as the particle becomes more ionizing, heavy-ion beams have been and remain the preferred tools for elucidating SEE vulnerabilities. In this talk we briefly discuss space radiation environments and SEE mechanisms, describe SEE test methodologies and discuss current and future challenges for use of heavy-ion beams for SEE testing in an era when the continued validity of Moore's law depends on innovation rather than CMOS scaling.

  3. No evidence of radiation risk for thyroid gland among schoolchildren around Semipalatinsk Nuclear Testing Site.

    Science.gov (United States)

    Hamada, Aiko; Takamura, Noboru; Meirmanov, Serik; Alipov, Gabit; Mine, Mariko; Ensebaev, Ruslan; Sagandikova, Sagadat; Ohashi, Toshinori; Yamashita, Shunichi

    2003-02-01

    To assess thyroid status among the schoolchildren around Semipalatinsk Nuclear Testing Site (SNTS), Kazakhstan, and to evaluate the current status of iodine deficiency in this area, we performed medical screening of schoolchildren in two villages, Kaynar and Karaul villages, East Kazakhstan Region, Republic of Kazakhstan, located within 100 km of SNTS. A total of 196 schoolchildren were chosen at random. Control groups comprised 250 schoolchildren from Nagasaki, an iodine-rich area, and 100 schoolchildren from Gomel, an iodine-deficient area contaminated by the Chernobyl Nuclear Power Plant accident. Ultrasound screening of thyroid revealed three cases of benign thyroid disease (two cases of goiter and one single cyst), but no cases suspicious of malignancy. The urinary iodine (UI) concentrations of subjects in Kaynar and Karaul ranged from 21.8 to 735.8 microg/L, 4.3% of whom showed low UI concentrations (tests carried out in SNTS.

  4. IBM ThinkPad radiation testing and recovery during EUROMIR missions

    International Nuclear Information System (INIS)

    Martignano, M.; Harboe-Sorensen, R.

    1995-01-01

    This paper presents the results of an experiment, conducted on-board the Russian MIR Space Station during a joint Russian and European mission, EUROMIR '94. A commercially available IBM ThinkPad 750C was evaluated by running a software system which monitored the notebook's behavior and counted the number of single event upsets. The used software system and ground verification tests are also presented. Finally, another software system, able to ruggedize normal personal computers for usage in space, is described

  5. Sensitivity tests of combination treatment with interleukin-2 and radiation against renal cell carcinoma using in vivo like growing culture system

    International Nuclear Information System (INIS)

    Onishi, Tetsuro; Machida, Toyohei; Asano, Kouji; Hatano, Takashi; Sawada, Takuko.

    1992-01-01

    We studied the effect of the combined therapy with interleukin-2 (IL-2) and radiation on renal cell carcinoma using an in vivo like growing culture system. We tested renal cell carcinoma obtained at surgery. After tumors were sliced into 2-mm square specimens, they were placed on a collagen gel-matrix filled with medium, and cultured for 7 days. 5 and 10 Gy were irradiated 3 days after the beginning of cell cultures. We also tested 100 JRU/ml of IL-2 added to each culture medium. The killing activity of each treatment was measured by the rate of 3 H-thymidine uptake. In the 5 Gy groups (n=9), we observed a significant effect in one treated with radiation alone (11.1%) and in 4 treated with the combined therapy (44.4%). Of these 4 having a significant effect with the combined therapy, one also had it with either radiation alone or combined therapy. The combined therapy was significantly effective compared with radiation alone. One had a significant effect with the combined therapy, and the remaining 2 had a significant effect by either combined therapy or radiation alone. In the 10 Gy group (n=12), a significant effect was seen in one with IL-2 treatment alone (8.3%), one with radiation alone (8.3%), and 4 with the combined therapy (33.3%). Of these 4 cases having a significant effects with the combined therapy, one had it by either radiation alone or the combined therapy, and the combined therapy was more effective than radiation alone. Two cases had a significant effect by the combined therapy, and the remaining one had it by either the combined therapy or radiation alone. We conclude that the combined therapy with IL-2 and radiation is effective for renal carcinoma, especially in the group irradiated with 5 Gy. (J.P.N.)

  6. Retrospective analysis of linac-based radiosurgery for arteriovenous malformations and testing of the Flickinger formula in predicting radiation injury

    Energy Technology Data Exchange (ETDEWEB)

    Cetin, I.A. [Universitair Ziekenhuis Brussel (Belgium). Dept. of Radiation Oncology; Marmara Univ., Ustkaynarca/Pendik (Turkey). Dept. of Radiation Oncology; Ates, R.; Dhaens, J.; Storme, G. [Universitair Ziekenhuis Brussel (Belgium). Dept. of Radiation Oncology

    2012-12-15

    Background and purpose: The aim of the study was to validate the use of linac-based radiosurgery in arteriovenous malformation (AVM) patients and to predict complications using an integrated logistic formula (ILF) in comparison with clinical outcomes. Patients and methods: The results of radiosurgery in 92 AVM patients were examined. All patients were treated with linac-based radiosurgery. Of these, 70 patients were followed for 12-45 months (median, 24 months) and were analyzed. The treated volume varied from 0.09 to 26.95 cm{sup 3} (median, 2.3 cm{sup 3}) and the median marginal dose was 20 Gy (range, 10.4-22). The median 12-Gy volume was 9.94 cm{sup 3} (range, 0.74-60.09 cm{sup 3}). Patients and lesion characteristics potentially affecting nidus obliteration and excellent outcome were evaluated by performing a log-rank test and univariate and multivariate analyses. The risk for radiation injury (RRI) was calculated with an integrated logistic formula. The predictive power of the RRI was assessed by calculating the area under the receiver operating characteristic (ROC) curve. Results: Follow-up magnetic resonance (MR) angiography revealed complete AVM obliteration in 56 of 70 patients. The MR angiography confirmed an obliteration rate of 80%. The annual hemorrhage rate was 1.4% for the first 2 years after radiosurgery and 0% thereafter. The number of patients with an excellent outcome was 48 (68%). Factors associated with better obliteration were higher radiation dose to the lesion margins [12-Gy volume (V12) > 10 cm{sup 3}], small volume, and a Pollock-Flickinger score less than 1.49; those predicting excellent outcomes were V12 < 10 cm{sup 3}, small volume, and Pollock-Flickinger score less than 1.49, as determined by multivariate analyses. Factors associated with radiation injury were V12 > 10 cm{sup 3} (p=0.03) and volume greater than 2 cm{sup 3} (p=0.001), as determined by a univariate analysis. The analyses showed an ROC of 0.66. Conclusion: These data

  7. Retrospective analysis of linac-based radiosurgery for arteriovenous malformations and testing of the Flickinger formula in predicting radiation injury

    International Nuclear Information System (INIS)

    Cetin, I.A.; Marmara Univ., Ustkaynarca/Pendik; Ates, R.; Dhaens, J.; Storme, G.

    2012-01-01

    Background and purpose: The aim of the study was to validate the use of linac-based radiosurgery in arteriovenous malformation (AVM) patients and to predict complications using an integrated logistic formula (ILF) in comparison with clinical outcomes. Patients and methods: The results of radiosurgery in 92 AVM patients were examined. All patients were treated with linac-based radiosurgery. Of these, 70 patients were followed for 12-45 months (median, 24 months) and were analyzed. The treated volume varied from 0.09 to 26.95 cm 3 (median, 2.3 cm 3 ) and the median marginal dose was 20 Gy (range, 10.4-22). The median 12-Gy volume was 9.94 cm 3 (range, 0.74-60.09 cm 3 ). Patients and lesion characteristics potentially affecting nidus obliteration and excellent outcome were evaluated by performing a log-rank test and univariate and multivariate analyses. The risk for radiation injury (RRI) was calculated with an integrated logistic formula. The predictive power of the RRI was assessed by calculating the area under the receiver operating characteristic (ROC) curve. Results: Follow-up magnetic resonance (MR) angiography revealed complete AVM obliteration in 56 of 70 patients. The MR angiography confirmed an obliteration rate of 80%. The annual hemorrhage rate was 1.4% for the first 2 years after radiosurgery and 0% thereafter. The number of patients with an excellent outcome was 48 (68%). Factors associated with better obliteration were higher radiation dose to the lesion margins [12-Gy volume (V12) > 10 cm 3 ], small volume, and a Pollock-Flickinger score less than 1.49; those predicting excellent outcomes were V12 3 , small volume, and Pollock-Flickinger score less than 1.49, as determined by multivariate analyses. Factors associated with radiation injury were V12 > 10 cm 3 (p=0.03) and volume greater than 2 cm 3 (p=0.001), as determined by a univariate analysis. The analyses showed an ROC of 0.66. Conclusion: These data suggest that linac-based radiosurgery is

  8. Electroweak radiative B-decays as a test of the Standard Model and beyond

    International Nuclear Information System (INIS)

    Tayduganov, A.

    2011-10-01

    Recently the radiative B-decay to strange axial-vector mesons, B → K 1 (1270)γ, was observed with a rather large branching ratio. This process is particularly interesting as the subsequent K 1 -decay into its three-body final state allows us to determine the polarization of the photon, which is mostly left(right)-handed for B-bar(B) in the Standard Model while various new physics models predict additional right(left)-handed components. In this thesis, a new method is proposed to determine the polarization, exploiting the full Dalitz plot distribution, which seems to reduce significantly the statistical errors on the polarization parameter λ γ measurement. This polarization measurement requires, however a detailed knowledge of the K 1 → Kππ strong interaction decays, namely, the complex pattern of various partial wave amplitudes into the several possible quasi-two-body channels as well as their relative phases. A number of experiments have been done to extract all these information while there remain various problems in the previous studies. In this thesis, we investigate the details of these problems. As a theoretical tool, we use the 3 P 0 quark-pair-creation model in order to improve our understanding of strong K 1 -decays. Finally we try to estimate some theoretical uncertainties: in particular, the one coming from the uncertainty on the K 1 mixing angle, and the effect of a possible 'off-set' phase in strong decay S-waves. According to our estimations, the systematic errors are found to be of the order of σ λ γ (th) ≤ 20%. On the other hand, we discuss the sensitivity of the future experiments, namely the SuperB factories and LHCb, to λ γ . Naively estimating the annual signal yields, we found the statistical error of the new method to be σ λ γ (stat) ≤ 10% which turns out to be reduced by a factor 2 with respect to using the simple angular distribution. We also discuss a comparison to the other methods of the polarization measurement using

  9. Modelling and testing the molecular mechanism of radiation-induced chromatid breaks

    International Nuclear Information System (INIS)

    Bryant, P. E.

    2001-01-01

    Chromatid breaks induced by ionizing radiation in the G2 phase of the cell cycle are considered as markers of individual human radiosensitivity and may indicate the presence of low-penetrance genes regulating susceptibility to breast and other cancers). Together with our own study of Scottish (Tayside) breast cancer patients and a group of normal controls these studies show an overall 10-fold variation in chromatid break frequency (the parameter defining individual chromosomal 'radiosensitivity'). Thus, an understanding of the mechanisms and genes involved in determining these widely different responses should help to clarify the reasons for individual radiosensitivity and may lead us to identify key genes involved in cancer susceptibility. The presence of colour-switches at around 16% of chromatid break points (detected in harlequin-stained chromosomes) indicates that this type of chromatid break is formed by a chromatin rearrangement involving one or more large chromatin domains of the order of 3 - 5 Mbp, possibly representing transcription 'factories'. The signal model of chromatid breaks assumes that all chromatid breaks are the result of chromatin rearrangements, and that the initiating DNA double-strand break (dsb) is itself not involved in the rearrangement but signals its presence (possibly via ATM protein or DNAPK) leading to the initiation of the chromatin rearrangement. Experimental evidence from radiosensitive cell lines (e.g. human AT and hamster irs2) and with the nucleoside analogue araA (9-β-D-arabinofuranosyladenine) demonstrates the lack of correspondence between the rejoining kinetics of dsb and that of disappearance of chromatid breaks, thus supporting the signal model. Coupled with the linear induction of chromatid breaks with dose in both human and rodent cell lines of various types, and the production of chromatid breaks by single dsb in genetically engineered cell lines the classical 'breakage-first' model of chromatid breaks is no longer

  10. A technician from NASDA test the real-time radiation monitoring device on SPACEHAB in preparation fo

    Science.gov (United States)

    1997-01-01

    A technician from the National Space Development Agency of Japan (NASDA) tests the real-time radiation monitoring device on SPACEHAB at Kennedy Space Center in preparation for the STS-89 mission, slated to be the first Shuttle launch of 1998. STS-89 will be the eighth of nine scheduled Mir dockings and will include a double module of SPACEHAB, used mainly as a large pressurized cargo container for science, logistical equipment and supplies to be exchanged between the orbiter Endeavour and the Russian Space Station Mir. The nine-day flight of STS-89 also is scheduled to include the transfer of the seventh American to live and work aboard the Russian orbiting outpost. Liftoff of Endeavour and its seven-member crew is targeted for Jan. 15, 1998, at 1:03 a.m. EDT from Launch Pad 39A.

  11. High energy beam impact tests on a LHC tertiary collimator at the CERN high-radiation to materials facility

    Directory of Open Access Journals (Sweden)

    Marija Cauchi

    2014-02-01

    Full Text Available The correct functioning of a collimation system is crucial to safely operate highly energetic particle accelerators, such as the Large Hadron Collider (LHC. The requirements to handle high intensity beams can be demanding. In this respect, investigating the consequences of LHC particle beams hitting tertiary collimators (TCTs in the experimental regions is a fundamental issue for machine protection. An experimental test was designed to investigate the robustness and effects of beam accidents on a fully assembled collimator, based on accident scenarios in the LHC. This experiment, carried out at the CERN High-Radiation to Materials (HiRadMat facility, involved 440 GeV proton beam impacts of different intensities on the jaws of a horizontal TCT. This paper presents the experimental setup and the preliminary results obtained, together with some first outcomes from visual inspection and a comparison of such results with numerical simulations.

  12. High energy beam impact tests on a LHC tertiary collimator at the CERN high-radiation to materials facility

    Science.gov (United States)

    Cauchi, Marija; Aberle, O.; Assmann, R. W.; Bertarelli, A.; Carra, F.; Cornelis, K.; Dallocchio, A.; Deboy, D.; Lari, L.; Redaelli, S.; Rossi, A.; Salvachua, B.; Mollicone, P.; Sammut, N.

    2014-02-01

    The correct functioning of a collimation system is crucial to safely operate highly energetic particle accelerators, such as the Large Hadron Collider (LHC). The requirements to handle high intensity beams can be demanding. In this respect, investigating the consequences of LHC particle beams hitting tertiary collimators (TCTs) in the experimental regions is a fundamental issue for machine protection. An experimental test was designed to investigate the robustness and effects of beam accidents on a fully assembled collimator, based on accident scenarios in the LHC. This experiment, carried out at the CERN High-Radiation to Materials (HiRadMat) facility, involved 440 GeV proton beam impacts of different intensities on the jaws of a horizontal TCT. This paper presents the experimental setup and the preliminary results obtained, together with some first outcomes from visual inspection and a comparison of such results with numerical simulations.

  13. Test of the Angle Detecting Inclined Sensor (ADIS) Technique for Measuring Space Radiation

    Science.gov (United States)

    Connell, J. J.; Lopate, C.; McLaughlin, K. R.

    2009-12-01

    In February 2008 we exposed an Angle Detecting Inclined Sensor (ADIS) prototype to beams of 150 MeV/u 78Kr and fragments at the National Superconducting Cyclotron Laboratory's (NSCL) Coupled Cyclotron Facility (CCF). ADIS is a highly innovative and uniquely simple detector configuration used to determine the angles of incidence of heavy ions in energetic charged particle instruments. Corrections for angle of incidence are required for good charge and mass separation. An ADIS instrument is under development to fly on the GOES-R series of weather satellites. The prototype tested consisted of three ADIS detectors, two of which were inclined at an angle to the telescope axis, forming the initial detectors in a five-detector telescope stack. By comparing the signals from the ADIS detectors, the angle of incidence may be determined and a pathlength correction applied to charge and mass determinations. Thus, ADIS replaces complex position sensing detectors with a system of simple, reliable and robust Si detectors. Accelerator data were taken at multiple angles to both primary and secondary beams with a spread of energies. This test instrument represents an improvement over the previous ADIS prototype in that it used oval inclined detectors and a much lower-mass support structure, thus reducing the number of events passing through dead material. These data show a charge peak resolution of 0.18 ± 0.01 e at Br (Z = 35), excellent for such a simple instrument. We will present the results of this test. The ADIS instrument development project was partially funded by NASA under the Living With a Star (LWS) Targeted Research and Technology program (grant NAG5-12493).

  14. L’évaluation du syndrome du Burnout chez les médecins en formation au CHU Ibn Rochd de Casablanca

    Science.gov (United States)

    El Kettani, Assiya; Serhier, Zineb; Othmani, Mohammed Bennani; Agoub, Mohamed; Battas, Omar

    2017-01-01

    Introduction Le Burnout est très répandu en milieu hospitalier et sa gravité est encore plus accrue chez les jeunes médecins. L'objectif est de déterminer la prévalence du burnout parmi les médecins en formation (internes et résidents) au CHU Ibn Rochd de Casablanca et chercher les facteurs associés. Méthodes Étude transversale descriptive menée en 2013- 2014 auprès d'un échantillon de 300 médecins à l'aide d'un questionnaire auto-administré; le burnout était évalué par la version française du Maslash Burnout Inventory (MBI). Résultats Un total de191 médecins a participé à l'étude (taux de réponse à 63,7%) avec une prédominance féminine à 79,1% et une moyenne d'âge de 26,7ans (ET = 3). Les scores moyens des sous-dimensions du MBI: l'épuisement émotionnel, la dépersonnalisation et l'accomplissement personnel étaient respectivement de (33,7 ± 10,7), (12,2 ± 6,5) et (30,6 ± 8,3). Le burnout sévère touchait 31,8% des participants. Il était associé aux problèmes de communication au sein de l'équipe soignante (p burnout sévère (p Burnout is very widespread in the hospital setting and it becomes much more severe in young physicians. The objective of this study aims to evaluate the prevalence of burnout among doctors in training (internal and residents) at the Ibn Rochd University Hospital, Casablanca and to identify factors associated with it. PMID:28979644

  15. Les complications chirurgicales de la transplantation rénale à partir du donneur vivant: expérience du CHU Ibn Sina de Rabat

    Directory of Open Access Journals (Sweden)

    Intissar Haddiya

    2010-09-01

    Full Text Available INTRODUCTION: La transplantation rénale (TR est actuellement considérée comme un traitement de choix de l’insuffisance rénale chronique terminale (IRCT. Ses résultats se sont améliorés au cours des dernières années. Cependant, les complications chirurgicales demeurent graves car elles touchent un rein unique et surviennent sur un terrain fragilisé par l’insuffisance rénale et l’immunosuppression. L’objectif de ce travail est d’évaluer la fréquence des complications chirurgicales lors de l’activité de TR au CHU Ibn Sina de Rabat, et de dégager les facteurs ayant influé l’apparition de ces complications. METHODES: Étude rétrospective des patients transplantés rénaux à partir de donneurs vivants apparentés (DVA de Juin 1999 à Décembre 2008 dans notre centre hospitalo-universitaire. Nous avons recensé les caractéristiques propres au receveur, au prélèvement, au donneur ainsi qu’au greffon. Les complications chirurgicales ont été colligées ainsi que leur prise en charge et évolution. RESULTATS: Soixante sept dossiers ont été analysés avec un suivi moyen de 55 +/- 28 mois. 38 complications chirurgicales ont été recensées : sténose des artères rénales (38,7%, lymphocèle (21%, hématome (12,7%, thrombose vasculaire (7,8%, reflux vésico-urétéral (4,8%, rupture du greffon (3,2%, calcul (1 cas, éventration (1 cas, L’analyse statistique de notre série n’a pas mis en évidence de facteurs de risque significatifs semblant influer sur l’incidence des complications chirurgicales. CONCLUSION: La morbidité liée aux complications chirurgicales de la TR reste élevée nécessitant un diagnostic et un traitement adéquat afin d’éviter les répercussions sur la survie des patients et des greffons.

  16. A simple quality assurance test tool for the visual verification of light and radiation field congruent using electronic portal images device and computed radiography

    Directory of Open Access Journals (Sweden)

    Njeh Christopher F

    2012-03-01

    Full Text Available Abstract Background The radiation field on most megavoltage radiation therapy units are shown by a light field projected through the collimator by a light source mounted inside the collimator. The light field is traditionally used for patient alignment. Hence it is imperative that the light field is congruent with the radiation field. Method A simple quality assurance tool has been designed for rapid and simple test of the light field and radiation field using electronic portal images device (EPID or computed radiography (CR. We tested this QA tool using Varian PortalVision and Elekta iViewGT EPID systems and Kodak CR system. Results Both the single and double exposure techniques were evaluated, with double exposure technique providing a better visualization of the light-radiation field markers. The light and radiation congruency could be detected within 1 mm. This will satisfy the American Association of Physicists in Medicine task group report number 142 recommendation of 2 mm tolerance. Conclusion The QA tool can be used with either an EPID or CR to provide a simple and rapid method to verify light and radiation field congruence.

  17. A simple quality assurance test tool for the visual verification of light and radiation field congruent using electronic portal images device and computed radiography

    International Nuclear Information System (INIS)

    Njeh, Christopher F; Caroprese, Blas; Desai, Pushkar

    2012-01-01

    The radiation field on most megavoltage radiation therapy units are shown by a light field projected through the collimator by a light source mounted inside the collimator. The light field is traditionally used for patient alignment. Hence it is imperative that the light field is congruent with the radiation field. A simple quality assurance tool has been designed for rapid and simple test of the light field and radiation field using electronic portal images device (EPID) or computed radiography (CR). We tested this QA tool using Varian PortalVision and Elekta iViewGT EPID systems and Kodak CR system. Both the single and double exposure techniques were evaluated, with double exposure technique providing a better visualization of the light-radiation field markers. The light and radiation congruency could be detected within 1 mm. This will satisfy the American Association of Physicists in Medicine task group report number 142 recommendation of 2 mm tolerance. The QA tool can be used with either an EPID or CR to provide a simple and rapid method to verify light and radiation field congruence

  18. The x-ray source application test cassette for radiation exposures at the OMEGA laser

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, K. B.; Rekow, V.; Emig, J. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Fisher, J. H.; Newlander, C. D. [Fifth Gait Technologies, Inc., Huntsville, Alabama 35803 (United States); Horton, R. [Gray Research, Inc., Huntsville, Alabama 35806 (United States); Davis, J. [Defense Threat Reduction Agency, Fort Belvoir, Virginia 22060 (United States)

    2012-10-15

    We have designed a sample cassette that can be used to position up to six samples in the OMEGA laser chamber. The cassette accommodates round samples up to 38.1 mm (1.5{sup Double-Prime }) in diameter and square samples up to 27 mm on a side, any of which can be up to 12.7 mm thick. Smaller specimens are centered with spacers. The test cassette allows each sample to have a unique filter scheme, with multiple filter regions in front of each sample. This paper will present mechanical design considerations and operational aspects of the x-ray source application cassette.

  19. Enhanced low dose rate radiation effect test on typical bipolar devices

    International Nuclear Information System (INIS)

    Liu Minbo; Chen Wei; Yao Zhibin; He Baoping; Huang Shaoyan; Sheng Jiangkun; Xiao Zhigang; Wang Zujun

    2014-01-01

    Two types of bipolar transistors and nine types bipolar integrated circuit were selected in the irradiation experiment at different "6"0Co γ dose rate. The base current of bipolar transistor and input bias current of amplifier and comparator was measured, low dose enhance factor of test device was obtained. The results show that bipolar device have enhanced low dose rate sensitivity, enhancement factor of bipolar integrated circuit was bigger than that of transistor, and enhanced low dose rate sensitivity greatly varied with different structure and process of bipolar device. (authors)

  20. Deoxyriboside determination and cytofluorometric test in rats at different points of time after radiation exposure

    International Nuclear Information System (INIS)

    Aleksandrov, S.N.; Bazanova, N.V.; Prokudina, E.A.; Safronova, V.G.; Yagunov, A.S.

    1976-01-01

    Whole-body X- or γ-irradiation with doses ranging from 200 to 400 rad is easily identifiable in rats within the succeeding days by determining the deoxyriboside level in blood and urine because of the almost linear correlation between the change of concentration and the dose level in the range under consideration. Within 4 weeks postirradiation the dose received may also be determined by measuring the intensity of ultraviolet fluorescence of the peripheral blood leukocytes. Subsequently, only a qualitative distinction between exposed and unexposed animals was still possible by means of this test up to the end of the investigation period. (author)