WorldWideScience

Sample records for chrysotile-containing joint compounds

  1. Radiation resistant, decontaminable and sealing jointing compounds for application in nuclear facilities

    International Nuclear Information System (INIS)

    Kunze, S.

    1991-09-01

    The sealing jointing compounds applied in practice and already examined for decontaminability will be presented here. Solvent-free sealing compounds, emulsifiable in water, with low molecular epoxy resins as binders, quite a number of curing versions, and little hygroscopic filler mixtures adapted in grain size have been tested with a view to ceramic tile jointing in nuclear facilities. The sealing compounds were examined before and after exposure to gamma irradiation (300 KGy energy dose) for decontaminability, color, gloss and resistance to decontaminants. Out of fourteeen compounds exhaustively investigated ten are very well decontaminable and four well decontaminable. After exposure to radiation no or only minor changes in color and gloss, respectively, were observed. Visible changes such as cracking, bubbles, etc. were not found and the resistance to decontaminants was neither affected. It has even been possible to replace in the well decontaminable sealing compounds developed until now part of the epoxy resin binder with elasticizing components such as Thiokol which is very important as a base material for sealing compounds in the construction industry, but difficult to decontaminate. (orig.) [de

  2. Mo-based compounds for SiC-SiC joints

    Energy Technology Data Exchange (ETDEWEB)

    Magnani, G.; Beaulardi, L.; Mingazzini, C. [ENEA-Faenza (Italy). New Material Div.; Marmo, E. [Fabbricazioni Nucleari S.p.A., Bosco Mavengo (Italy)

    2002-07-01

    New method to joint silicon carbide-based material was developed. It was based on mixture composed mainly by molybdenum silicides. This mixture was tested as brazing mixture with several types of silicon carbide-based material. Microstructural examination of the joint showed that brazing mixture reacted with substrate to form silicon carbide on the surface, while two different molybdenum silicides were identified inside the joint (MoSi{sub 2} and Mo{sub 4.8}Si{sub 3}C{sub 0.6}). Preliminary oxidation tests performed by means of TGA showed high oxidation resistance of this joint over 1000 C making it very promising for high temperature application like ceramic heat exchanger. (orig.)

  3. Design of a Slowed-Rotor Compound Helicopter for Future Joint Service Missions

    Science.gov (United States)

    Silva, Christopher; Yeo, Hyeonsoo; Johnson, Wayne R.

    2010-01-01

    A slowed-rotor compound helicopter has been synthesized using the NASA Design and Analysis of Rotorcraft (NDARC) conceptual design software. An overview of the design process and the capabilities of NDARC are presented. The benefits of trading rotor speed, wing-rotor lift share, and trim strategies are presented for an example set of sizing conditions and missions.

  4. Inhibition of the formation of intermetallic compounds in aluminum-steel welded joints by friction stir welding

    Directory of Open Access Journals (Sweden)

    Torres López, Edwar A.

    2015-12-01

    Full Text Available Formation of deleterious phases during welding of aluminum and steel is a challenge of the welding processes, for decades. Friction Stir Welding (FSW has been used in an attempt to reduce formation of intermetallic compounds trough reducing the heat input. In this research, dissimilar joint of 6063-T5 aluminum alloy and AISI-SAE 1020 steel were welded using this technique. The temperature of welded joints was measured during the process. The interface of the welded joints was characterized using optical microscopy, scanning and transmission electron microscopy. Additionally, composition measurements were carried out by X-EDS and DRX. The experimental results revealed that the maximum temperature on the joint studied is less than 360 °C. The microstructural characterization in the aluminum-steel interface showed the absence of intermetallic compounds, which is a condition attributed to the use of welding with low thermal input parameters.La unión de juntas aluminio-acero, sin la formación de fases deletéreas del tipo FexAly, ha sido, por décadas, un desafío para los procesos de soldadura. La soldadura por fricción-agitación ha sido empleada para intentar reducir el aporte térmico y evitar la formación de compuestos intermetálicos. Usando esta técnica fueron soldadas juntas disimilares de aluminio 6063-T5 y acero AISI-SAE 1020. La soldadura fue acompañada de medidas de temperatura durante su ejecución. La interfase de las juntas soldadas fue caracterizada utilizando microscopía óptica, electrónica de barrido y electrónica de transmisión. Adicionalmente fueron realizadas medidas puntuales X-EDS y DRX. Los resultados experimentales revelan que la temperatura máxima en la junta es inferior a 360 °C. La caracterización microestructural en la interfase aluminio-acero demostró la ausencia de compuestos intermetálicos, condición atribuida al uso de parámetros de soldadura con bajo aporte térmico.

  5. Control of early-formed vesicle cylinders on upper crustal prismatic jointing in compound pāhoehoe lavas of Elephanta Island, western Deccan Traps, India

    Science.gov (United States)

    Sheth, Hetu; Patel, Vanit; Samant, Hrishikesh

    2017-08-01

    Upper crustal prismatic joints and vesicle cylinders, common in pāhoehoe lava flows, form early and late, respectively, and are therefore independent features. However, small-scale compound pāhoehoe lava lobes on Elephanta Island (western Deccan Traps, India), which resemble S-type (spongy) pāhoehoe in some aspects, contain vesicle cylinders which apparently controlled the locations of upper crustal prismatic joints. The lobes are decimeters thick, did not experience inflation after emplacement, and solidified rapidly. They have meter-scale areas that are exceptionally rich in vesicle cylinders (up to 68 cylinders in 1 m2, with a mean spacing of 12.1 cm), separated by cylinder-free areas, and pervasive upper crustal prismatic jointing with T, curved T, and quadruple joint intersections. A majority (≥76.5%) of the cylinders are located exactly on joints or at joint intersections, and were not simply captured by downward growing joints, as the cylinders show no deflection in vertical section. We suggest that large numbers of cylinders originated in a layer of bubble-rich residual liquid at the top of a basal diktytaxitic crystal mush zone which was formed very early (probably within the first few minutes of the emplacement history). The locations where the rising cylinders breached the crust provided weak points or mechanical flaws towards which any existing joints (formed by thermal contraction) propagated. New joints may also have propagated outwards from the cylinders and linked up laterally. Some cylinders breached the crust between the joints, and thus formed a little later than most others. The Elephanta Island example reveals that, whereas thermal contraction is undoubtedly valid as a standard mechanism for forming upper crustal prismatic joints, abundant mechanical flaws (such as large concentrations of early-formed, crust-breaching vesicle cylinders) can also control the joint formation process.

  6. Homogeneous (Cu, Ni)6Sn5 intermetallic compound joints rapidly formed in asymmetrical Ni/Sn/Cu system using ultrasound-induced transient liquid phase soldering process.

    Science.gov (United States)

    Li, Z L; Dong, H J; Song, X G; Zhao, H Y; Tian, H; Liu, J H; Feng, J C; Yan, J C

    2018-04-01

    Homogeneous (Cu, Ni) 6 Sn 5 intermetallic compound (IMC) joints were rapidly formed in asymmetrical Ni/Sn/Cu system by an ultrasound-induced transient liquid phase (TLP) soldering process. In the traditional TLP soldering process, the intermetallic joints formed in Ni/Sn/Cu system consisted of major (Cu, Ni) 6 Sn 5 and minor Cu 3 Sn IMCs, and the grain morphology of (Cu, Ni) 6 Sn 5 IMCs subsequently exhibited fine rounded, needlelike and coarse rounded shapes from the Ni side to the Cu side, which was highly in accordance with the Ni concentration gradient across the joints. However, in the ultrasound-induced TLP soldering process, the intermetallic joints formed in Ni/Sn/Cu system only consisted of the (Cu, Ni) 6 Sn 5 IMCs which exhibited an uniform grain morphology of rounded shape with a remarkably narrowed Ni concentration gradient. The ultrasound-induced homogeneous intermetallic joints exhibited higher shear strength (61.6 MPa) than the traditional heterogeneous intermetallic joints (49.8 MPa). Copyright © 2017 Elsevier B.V. All rights reserved.

  7. A Low Temperature Detoxification Method for Treatment of Chrysotile-Containing Waste Roofing Slate

    Directory of Open Access Journals (Sweden)

    Hwanju Jo

    2017-08-01

    Full Text Available In this study, we evaluated a two-step process for detoxification of waste roofing slate, involving cement hydrate removal and low temperature detoxification using oxalic acid. These treatments were conducted on raw material and intermediate product, respectively. Cement hydrate removal effectively eliminated most Ca-containing cement hydrate components from the raw material under the following conditions: HCl to solid ratio: 0.456 g/g, reaction time: 2 h, and solid to liquid ratio: 0.124 g/mL. Following low temperature (~100 °C detoxification of intermediate product obtained after cement hydrate removal, chrysotile in waste roofing slate was effectively transformed to Mg-oxalate under conditions of oxalic acid to solid ratio of >0.67 g/g.

  8. 99m-Technetium phosphate compound joint scintigraphy in the management of juvenile osteochondritis dissecans of the femoral condyles

    International Nuclear Information System (INIS)

    Cahill, B.R.; Berg, B.C.

    1983-01-01

    The known sensitivity of joint scintigraphy in following the course of fracture healing caused the authors to believe that this radiologic technique might be valuable in the management of osteochondritis dissecans (OCD). Accordingly, 99mTc-diphosphonate joint scintigraphy was used on 18 patients with OCD of the knee. The average age was 13 1/2 years. The scintigrams were repeated at 6-week intervals until healing had occurred. When the diagnosis of OCD was established by standard roentgenograms and joint scintigraphy, the patients were placed on an activity restriction program, attempting to reach a symptom-free level. The patients were followed for an average of 18 months. Ninety-five scans were categorized according to their level of scintigraphic activity. This led to a discrete four-part scintigraphic classification that is indicative of the extent of healing or progression of this condition, and precedes changes seen on standard x-rays by months. Joint scintigraphy also rules out anomalies of ossification in the diagnosis of OCD since an anomaly should have a normal scintigraphic appearance. We have concluded that joint scintigraphy is valuable in the management of OCD because of its superior sensitivity to changes in the activity of the lesion. As experience is gained with this technique, those cases that should be prophylactically surgically stabilized may be indicated

  9. Abnormal accumulation of intermetallic compound at cathode in a SnAg3.0Cu0.5 lap joint during electromigration

    International Nuclear Information System (INIS)

    Li Mingyu; Chang Hong; Pang Xiaochao; Wang Ling; Fu Yonggao

    2011-01-01

    Interfacial reactions in a SnAg 3.0 Cu 0.5 /Cu lap joint for naked and encompassed specimens were investigated contrastively under electric current stressing. After applying a constant direct current at 6.5 A for 144 h, an abnormal accumulation of bulk Cu 6 Sn 5 intermetallic compound was found at the cathode for the naked specimen. But normal polarization phenomenon arose for the encompassed specimen at the same current density for 504 h. The abnormal accumulation phenomenon was explained by the mechanism that thermomigration and stress migration induced by temperature gradient dominated the migration process. A three-dimensional joint simulation model was designed to demonstrate how current crowding and temperature gradient can enhance the local atomic flux.

  10. Influence of nanoparticle addition on the formation and growth of intermetallic compounds (IMCs) in Cu/Sn–Ag–Cu/Cu solder joint during different thermal conditions

    Science.gov (United States)

    Ting Tan, Ai; Wen Tan, Ai; Yusof, Farazila

    2015-01-01

    Nanocomposite lead-free solders are gaining prominence as replacements for conventional lead-free solders such as Sn–Ag–Cu solder in the electronic packaging industry. They are fabricated by adding nanoparticles such as metallic and ceramic particles into conventional lead-free solder. It is reported that the addition of such nanoparticles could strengthen the solder matrix, refine the intermetallic compounds (IMCs) formed and suppress the growth of IMCs when the joint is subjected to different thermal conditions such as thermal aging and thermal cycling. In this paper, we first review the fundamental studies on the formation and growth of IMCs in lead-free solder joints. Subsequently, we discuss the effect of the addition of nanoparticles on IMC formation and their growth under several thermal conditions. Finally, an outlook on the future growth of research in the fabrication of nanocomposite solder is provided. PMID:27877786

  11. Influence of nanoparticle addition on the formation and growth of intermetallic compounds (IMCs) in Cu/Sn–Ag–Cu/Cu solder joint during different thermal conditions

    International Nuclear Information System (INIS)

    Ting Tan, Ai; Wen Tan, Ai; Yusof, Farazila

    2015-01-01

    Nanocomposite lead-free solders are gaining prominence as replacements for conventional lead-free solders such as Sn–Ag–Cu solder in the electronic packaging industry. They are fabricated by adding nanoparticles such as metallic and ceramic particles into conventional lead-free solder. It is reported that the addition of such nanoparticles could strengthen the solder matrix, refine the intermetallic compounds (IMCs) formed and suppress the growth of IMCs when the joint is subjected to different thermal conditions such as thermal aging and thermal cycling. In this paper, we first review the fundamental studies on the formation and growth of IMCs in lead-free solder joints. Subsequently, we discuss the effect of the addition of nanoparticles on IMC formation and their growth under several thermal conditions. Finally, an outlook on the future growth of research in the fabrication of nanocomposite solder is provided. (review)

  12. Inhibition of the formation of intermetallic compounds in aluminum-steel welded joints by friction stir welding; Inhibicion de la formacion de compuestos intermetalicos en juntas aluminio-acero soldadas por friccion-agitacion

    Energy Technology Data Exchange (ETDEWEB)

    Torres Lopez, E. A.; Ramirez, A. J.

    2015-07-01

    Formation of deleterious phases during welding of aluminum and steel is a challenge of the welding processes, for decades. Friction Stir Welding (FSW) has been used in an attempt to reduce formation of intermetallic compounds trough reducing the heat input. In this research, dissimilar joint of 6063-T5 aluminum alloy and AISI-SAE 1020 steel were welded using this technique. The temperature of welded joints was measured during the process. The interface of the welded joints was characterized using optical microscopy, scanning and transmission electron microscopy. Additionally, composition measurements were carried out by X-EDS and DRX. The experimental results revealed that the maximum temperature on the joint studied is less than 360 degree centigrade. The microstructural characterization in the aluminum-steel interface showed the absence of intermetallic compounds, which is a condition attributed to the use of welding with low thermal input parameters. (Author)

  13. Systematics of Structural, Phase Stability, and Cohesive Properties of η'-Cu6(Sn,In)5 Compounds Occurring in In-Sn/Cu Solder Joints

    Science.gov (United States)

    Ramos, S. B.; González Lemus, N. V.; Deluque Toro, C. E.; Cabeza, G. F.; Fernández Guillermet, A.

    2017-07-01

    Motivated by the high solubility of In in ( mC44) η'-Cu6Sn5 compound as well as the occurrence of an In-doped η'-intermetallic in the microstructure of Cu/In-Sn/Cu solder joints, a theoretical study has been carried out to investigate the various physical effects of incorporating In at Sn Wyckoff sites of the binary η'-phase. Systematic ab initio calculations using the projected augmented wave method and Vienna Ab initio Simulation Package were used to determine the composition dependence of the structural and cohesive properties of η'-Cu6(Sn,In)5 compounds, compared with those expected from the binary end-member compounds Cu6Sn5 and Cu6In5. The molar volume shows significant deviations from Vegard's law. The predicted composition dependence of the cohesive properties is discussed using two complementary approaches, viz. a valence-electron density approach as well as a bond-number approach, both accounting for the roughly linear dependence of the cohesive energy on the In content. A microscopic interpretation for this general trend is given in terms of the key contributions to chemical bonding in this class of compounds, namely Cu d-electron overlap and hybridization of Cu d-states with In and Sn p-electron states. Moreover, a crystallographic site approach is developed to accurately establish the phase-stabilizing effect of incorporating In at specific Wyckoff positions of the ( mC44) η'-Cu6Sn5 structure.

  14. A Correlation between the Ultimate Shear Stress and the Thickness Affected by Intermetallic Compounds in Friction Stir Welding of Dissimilar Aluminum Alloy–Stainless Steel Joints

    Directory of Open Access Journals (Sweden)

    Florent Picot

    2018-03-01

    Full Text Available In this work, Friction Stir Welding (FSW was applied to join a stainless steel 316L and an aluminum alloy 5083. Ranges of rotation and translation speeds of the tool were used to obtain welding samples with different heat input coefficients. Depending on the process parameters, the heat generated by FSW creates thin layers of Al-rich InterMetallic Compound (IMC mainly composed of FeAl3, identified by energy dispersive spectrometry. Traces of Fe2Al5 were also depicted in some samples by X-ray diffraction analysis and transmission electron microscopy. Monotonous tensile tests performed on the weld joint show the existence of a maximum mechanical resistance for a judicious choice of rotation and translation speeds. It can be linked to an affected zone of average thickness of 15 µm which encompass the presence of IMC and the chaotic mixing caused by plastic deformation in this area. A thickness of less than 15 µm is not sufficient to ensure a good mechanical resistance of the joint. For a thickness higher than 15 µm, IMC layers become more brittle and less adhesive due to high residual stresses which induces numerous cracks after cooling. This leads to a progressive decrease of the ultimate shear stress supported by the bond.

  15. [Research of repairing rabbit knee joint cartilage defect by compound material of fibrin glue and decalcified bone matrix (DBM) and chondrocytes].

    Science.gov (United States)

    He, Jie; Yang, Xiang; Yue, Peng-ju; Wang, Guan-yu; Guo, Ting; Zhao, Jian-ning

    2009-07-01

    To investigate the feasibility and effectivity of using compound material of fibrin glue and DBM as scaffolds for cartilage tissue engineering. Chondrocytes isolated from articular cartilage were seeded into prepared scaffolds, after incubation for 4 weeks in vitro. Chondrocytes and fibrin glue and DBM constructs were implanted in the joint cave of rabbit. The specimens were excised at the 4th, 8th, 12th week, examined grossly analyzed by haematoxylin cosine, toluidine blues staining and type II collagen immunohistochemistry reaction. Wakitani score was counted to evaluate the repairing effect. Grossly analysis showed some ivory tissue filled the caves after 4 weeks and the caves were full filled with smooth surface after 12 weeks. The microscope showed a good deal of chondrocytes appeared after 8 weeks and more type II collagen than 4 weeks. Twelve weeks later, cartilage lacuna could be observed. The cells arrangement and the amount of type II collagen both showed the same as the natural one. Complicated material of fibrin glue and DBM as scaffolds can be used as scaffolds for cartilage tissue engineering.

  16. Toward rapid analysis, forecast and discovery of bioactive compounds from herbs by jointly using thin layer chromatography and ratiometric surface-enhanced Raman spectroscopy technique.

    Science.gov (United States)

    Gu, Xiaoling; Jin, Yang; Dong, Fang; Cai, Yueqing; You, Zhengyi; You, Junhui; Zhang, Liying; Du, Shuhu

    2018-05-10

    Conventional isolation and identification of active compounds from herbs have been extensively reported by using various chromatographic and spectroscopic techniques. However, how to quickly discover new bioactive ingredients from natural sources still remains a challenging task due to the interference of their similar structures or matrices. Here, we present a grand approach for rapid analysis, forecast and discovery of bioactive compounds from herbs based on a hyphenated strategy of thin layer chromatography and ratiometric surface-enhanced Raman spectroscopy. The performance of the hyphenated strategy is first evaluated by analyzing four protoberberine alkaloids, berberine (BER), coptisine (COP), palmatine (PAT) and jatrorrhizine (JAT), from a typical herb Coptidis Rhizoma as an example. It has been demonstrated that this coupling method can identify the four compounds by characteristic peaks at 728, 708, 736 and 732 cm -1 , and especially discriminate BER and COP (with similar migration distances) by ratiometric Raman intensity (I 708 /I 728 ). The corresponding limits of detection are 0.1, 0.05, 0.1 and 0.5 μM, respectively, which are about 1-2 orders of magnitude lower than those of direct observation method under 254 nm UV lamp. Based on these findings, the proposed method further guides forecast and discovery of unknown compounds from traditional Chinese herb Typhonii Rhizoma. Results infer that two trace alkaloids (BER and COP) from the n-butanol extract of Typhonii Rhizoma are found for the first time. Moreover, in vitro experiments manifest that BER can effectively decrease the viability of human glioma U87 cells by inducing cell cycle arrest in a concentration-dependent manner. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Joint ventures

    DEFF Research Database (Denmark)

    Sørensen, Karsten Engsig

    Afhandlingen analysere de konkurrenceretlige og selskabsretlige regler som er bestemmende for hvordan et joint venture samarbejde er struktureret......Afhandlingen analysere de konkurrenceretlige og selskabsretlige regler som er bestemmende for hvordan et joint venture samarbejde er struktureret...

  18. Coracoclavicular joint

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kun Sang; Park, Chan Il; Ahn, Jae Doo; Lim, Chong Won [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1970-10-15

    The coracoclvicular joint, a rear abnormality which may be the cause of pain in the shoulder and limitation of motion of the shoulder joint, is discussed. A case of coracoclvicular joint with shoulder pain was observed in 65 yrs old Korean male.

  19. From the Cover: Vulnerability of C6 Astrocytoma Cells After Single-Compound and Joint Exposure to Type I and Type II Pyrethroid Insecticides.

    Science.gov (United States)

    Romero, Delfina M; Berardino, Bruno G; Wolansky, Marcelo J; Kotler, Mónica L

    2017-01-01

    A primary mode-of-action of all pyrethroid insecticides (PYRs) is the disruption of the voltage-gated sodium channel electrophysiology in neurons of target pests and nontarget species. The neurological actions of PYRs on non-neuronal cells of the nervous system remain poorly investigated. In the present work, we used C6 astrocytoma cells to study PYR actions (0.1-50 μM) under the hypothesis that glial cells may be targeted by and vulnerable to PYRs. To this end, we characterized the effects of bifenthrin (BF), tefluthrin (TF), α-cypermethrin (α-CYP), and deltamethrin (DM) on the integrity of nuclear, mitochondrial, and lysosomal compartments. In general, 24- to 48-h exposures produced concentration-related impairment of cell viability. In single-compound, 24-h exposure experiments, effective concentration (EC) 15 s 3-(4,5-dimethyl-thiazol-2-yl)-2,5-diphenyl-tetrazolium bromide (MTT assay) were computed as follows (in μM): BF, 16.1; TF, 37.3; α-CYP, 7.8; DM, 5.0. We found concentration-related damage in several C6-cell subcellular compartments (mitochondria, nuclei, and lysosomes) at ≥ 10 -1 μM levels. Last, we examined a mixture of all PYRs (ie, Σ individual EC 15 ) using MTT assays and subcellular analyses. Our findings indicate that C6 cells are responsive to nM levels of PYRs, suggesting that astroglial susceptibility may contribute to the low-dose neurological effects caused by these insecticides. This research further suggests that C6 cells may provide relevant information as a screening platform for pesticide mixtures targeting nervous system cells by expected and unexpected toxicogenic pathways potentially contributing to clinical neurotoxicity. © The Author 2016. Published by Oxford University Press on behalf of the Society of Toxicology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  20. Temporomandibular joint

    International Nuclear Information System (INIS)

    Westesson, P.L.; Hatala, M.; Tallents, R.H.; Katzberg, R.W.; Musgrave, M.; Levitt, S.

    1990-01-01

    This paper determines the frequency of MR signs of abnormal temporomandibular joints (TMJs) in asymptomatic volunteers. Forty-two volunteers with 84 clinically normal TMJs were imaged in the sagittal and coronal planes with surface coil MR imaging. Sagittal closed and open and coronal closed views were obtained bilaterally in all volunteers. The images were classified as normal (superior disk position) or abnormal (disk displacement of degenerative joint disease). Eighteen joints in 11 volunteers were abnormal; 12 had disk displacement with reduction and six had disk displacement without reduction, with associated degenerative joint disease in three of the six. Asymptomatic internal derangement and degenerative joint disease occur in about one-fourth of asymptomatic volunteers

  1. Joint diseases

    International Nuclear Information System (INIS)

    Weissman, S.D.

    1989-01-01

    The authors discuss how x-ray examination is essential in the diagnosis and evaluation of the arthritides. Most arthritides are first suspected by the clinician, and x-ray evaluation of these entities along with laboratory testing is important for confirmation of the clinical diagnosis and in staging of the disease process. Several arthritides are often diagnosed first by the podiatrist on x-ray evaluation, including pseudogout, ankylosing spondylitis, early rheumatoid arthritis, degenerative joint disease, and tuberculosis of bone. The joint responds to insult in only a limited number of ways that become apparent on x-ray. The soft tissues surrounding the joint, the articulating bones, and alignment of the joint space may all be involved by the arthritic process. On roentgenographic examination, the soft tissues must be examined for edema, masses, calcifications, and atrophy. The articulating bones must be examined for demineralization, erosions, osteophytes, periosteal reaction, cysts and sclerosis

  2. Joint pain

    Science.gov (United States)

    ... or conditions. It may be linked to arthritis , bursitis , and muscle pain . No matter what causes it, ... Autoimmune diseases such as rheumatoid arthritis and lupus Bursitis Chondromalacia patellae Crystals in the joint: Gout (especially ...

  3. Joint Commission

    Science.gov (United States)

    ... for the latest publication of The Joint Commission Journal on Quality and Patient Safety (JQPS). . How We Work Process improvement program breeds quality culture, empowers staff An article in Quality Progress, June ...

  4. Joint Intentionality

    Directory of Open Access Journals (Sweden)

    Koreň Ladislav

    2016-03-01

    Full Text Available According to the shared intentionality hypothesis proposed by Michael Tomasello, two cognitive upgrades – joint and collective intentionality, respectively – make human thinking unique. Joint intentionality, in particular, is a mindset supposed to account for our early, species-specific capacity to participate in collaborative activities involving two (or a few agents. In order to elucidate such activities and their proximate cognitive-motivational mechanism, Tomasello draws on philosophical accounts of shared intentionality. I argue that his deference to such cognitively demanding accounts of shared intentional activities is problematic if his theoretical ambition is in part to show that and how early (prelinguistic and precultural capacities for joint action contribute to the development of higher cognitive capacities.

  5. Joint imaging

    International Nuclear Information System (INIS)

    Hengst, W.

    1984-01-01

    Joint imaging is a proven diagnostic procedure which has become indispensable to the detection and treatment of different joint diseases in almost all disciplines. The method is suited for early diagnosis of joint affections both in soft tissue and bone which cannot be detected by X-ray or other procedures. The local activity accumulation depends on the rate of metabolism and is visualized in the scan, which in turn enables the extension and floridity of focal lesions to be evaluated and followed-up. Although joint scans may often give hints to probabilities relevant to differential diagnosis, the method is non-specific and only useful if based on the underlying clinical picture and X-ray finding, if possible. The radiation exposure is very low and does not represent a hazard in cases of adequate assessment of indication. In pregnant women and children the assessment of indication has to be based on very strict principles. The method is suited for out-patient diagnosis and can be applied in all installations equipped with a gamma camera and a technetium generator. (orig.) [de

  6. Joint purpose?

    DEFF Research Database (Denmark)

    Pristed Nielsen, Helene

    2013-01-01

    Starting from Crenshaw´s point that antiracism often fails to interrogate patriarchy and that feminism often reproduces racist practices (1991: 1252), this paper asks: What are the theoretical reasons for believing that feminism and anti-racism can be regarded as fighting for the joint purpose...

  7. Joint Operation Planning

    National Research Council Canada - National Science Library

    2006-01-01

    .... It sets forth joint doctrine to govern the joint operation planning activities and performance of the Armed Forces of the United States in joint operations, and provides the joint doctrinal basis...

  8. Effect of Strain Rate on Joint Strength and Failure Mode of Lead-Free Solder Joints

    Science.gov (United States)

    Lin, Jian; Lei, Yongping; Fu, Hanguang; Guo, Fu

    2018-03-01

    In surface mount technology, the Sn-3.0Ag-0.5Cu solder joint has a shorter impact lifetime than a traditional lead-tin solder joint. In order to improve the impact property of SnAgCu lead-free solder joints and identify the effect of silver content on tensile strength and impact property, impact experiments were conducted at various strain rates on three selected SnAgCu based solder joints. It was found that joint failure mainly occurred in the solder material with large plastic deformation under low strain rate, while joint failure occurred at the brittle intermetallic compound layer without any plastic deformation at a high strain rate. Joint strength increased with the silver content in SnAgCu alloys in static tensile tests, while the impact property of the solder joint decreased with increasing silver content. When the strain rate was low, plastic deformation occurred with failure and the tensile strength of the Sn-3.0Ag-0.5Cu solder joint was higher than that of Sn-0.3Ag-0.7Cu; when the strain rate was high, joint failure mainly occurred at the brittle interface layer and the Sn-0.3Ag-0.7Cu solder joint had a better impact resistance with a thinner intermetallic compound layer.

  9. Melt formed superconducting joint between superconducting tapes

    International Nuclear Information System (INIS)

    Benz, M.G.; Knudsen, B.A.; Rumaner, L.E.; Zaabala, R.J.

    1992-01-01

    This patent describes a superconducting joint between contiguous superconducting tapes having an inner laminate comprised of a parent-metal layer selected from the group niobium, tantalum, technetium, and vanadium, a superconductive intermetallic compound layer on the parent-metal layer, a reactive-metal layer that is capable of combining with the parent-metal and forming the superconductive intermetallic compound, the joint comprising: a continuous precipitate of the superconductive intermetallic compound fused to the tapes forming a continuous superconducting path between the tapes

  10. Assessing in Vitro Acaricidal Effect and Joint Action of a Binary Mixture Between Essential Oil Compounds (Thymol, Phellandrene, Eucalyptol, Cinnamaldehyde, Myrcene, Carvacrol Over Ectoparasitic Mite Varroa Destructor (Acari: Varroidae

    Directory of Open Access Journals (Sweden)

    Brasesco Constanza

    2017-12-01

    Full Text Available Varroa destructor (Anderson & Trueman, 2000 causes the most important parasitosis of beekeeping in the world. For this reason, prevention is needed to avoid colony death. The most typical treatments involve synthetic acaricides. However, the use of these acaricides results in the emergence of resistant populations of mites to these products and in the appearances of drug residues in products of the hives. Compounds of essential oils have emerged as an alternative to traditional acaricides; however the toxicity produced by these mixtures is currently poorly explored. The aim of this work was to assess, by means of in vitro tests with adult bees, how acaricidal action and toxic interactions in a binary mixture of essential oil compounds (Thymol, Phellandrene, Eucalyptol, Cinnamaldehyde, Myrcene, and Carvacrol affect V. destructor. Calculations of LC50 ’s of the individual compounds on A. mellifera and V. destructor made clear that the toxic effect of each compound is different for both species. Thymol and Phellandrene turned out to be lethal for mites at lower concentrations than for bees. The binary mixture of these two substances presented a different toxicity than one produced by each pure compound, as it was highly selective for mites in bioassays at 24 hours through complete exposure to both A. mellifera and V. destructor. These results make such formulations optimal substances to be considered as alternative controls for the parasitosis.

  11. Joint Instability and Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Darryl Blalock

    2015-01-01

    Full Text Available Joint instability creates a clinical and economic burden in the health care system. Injuries and disorders that directly damage the joint structure or lead to joint instability are highly associated with osteoarthritis (OA. Thus, understanding the physiology of joint stability and the mechanisms of joint instability-induced OA is of clinical significance. The first section of this review discusses the structure and function of major joint tissues, including periarticular muscles, which play a significant role in joint stability. Because the knee, ankle, and shoulder joints demonstrate a high incidence of ligament injury and joint instability, the second section summarizes the mechanisms of ligament injury-associated joint instability of these joints. The final section highlights the recent advances in the understanding of the mechanical and biological mechanisms of joint instability-induced OA. These advances may lead to new opportunities for clinical intervention in the prevention and early treatment of OA.

  12. Joint instability and osteoarthritis.

    Science.gov (United States)

    Blalock, Darryl; Miller, Andrew; Tilley, Michael; Wang, Jinxi

    2015-01-01

    Joint instability creates a clinical and economic burden in the health care system. Injuries and disorders that directly damage the joint structure or lead to joint instability are highly associated with osteoarthritis (OA). Thus, understanding the physiology of joint stability and the mechanisms of joint instability-induced OA is of clinical significance. The first section of this review discusses the structure and function of major joint tissues, including periarticular muscles, which play a significant role in joint stability. Because the knee, ankle, and shoulder joints demonstrate a high incidence of ligament injury and joint instability, the second section summarizes the mechanisms of ligament injury-associated joint instability of these joints. The final section highlights the recent advances in the understanding of the mechanical and biological mechanisms of joint instability-induced OA. These advances may lead to new opportunities for clinical intervention in the prevention and early treatment of OA.

  13. Organolanthanoid compounds

    International Nuclear Information System (INIS)

    Schumann, H.

    1984-01-01

    Up to little more than a decade ago organolanthanoid compounds were still a curiosity. Apart from the description of an isolated number of cyclopentadienyl and indenyl derivatives, very few significant contributions had been made to this interesting sector of organometallic chemistry. However, subsequent systematic studies using modern preparative and analytical techniques, together with X-ray single crystal structure determinations, enabled the isolation and characterization of a large number of very interesting homoleptic and heteroleptic compounds in which the lanthanoid is bound to hydrogen, to substituted or unsubstituted cyclopentadienyl groups, to allyl or alkynyl groups, or even to phosphorus ylides, trimethylsilyl, and carbonylmetal groups. These compounds, which are all extremely sensitive to oxygen and water, open up new possibilities in the field of catalysis and have great potential in organic synthesis - as recent studies with pentamethylcyclopentadienyl derivatives, organolanthanoid(II) compounds, and hexamethyllanthanoid complexes have already shown. (orig.) [de

  14. International joint ventures

    DEFF Research Database (Denmark)

    Sørensen, Karsten Engsig

    2001-01-01

    The article analysis problems connected with corporate joint ventures. Among others the possible conflicts between the joint venture agreement and the statutes of the companies is examined, as well as certain problems connected to the fact that the joint venture partners have created commen control...... over their joint company....

  15. Multipurpose Compound

    Science.gov (United States)

    1983-01-01

    Specially formulated derivatives of an unusual basic compound known as Alcide may be the answer to effective treatment and prevention of the disease bovine mastitis, a bacterial inflammation of a cow's mammary gland that results in loss of milk production and in extreme cases, death. Manufactured by Alcide Corporation the Alcide compound has killed all tested bacteria, virus and fungi, shortly after contact, with minimal toxic effects on humans or animals. Alcide Corporation credits the existence of the mastitis treatment/prevention products to assistance provided the company by NERAC, Inc.

  16. Joint Center Estimation Using Single-Frame Optimization: Part 1: Numerical Simulation

    OpenAIRE

    Eric Frick; Salam Rahmatalla

    2018-01-01

    The biomechanical models used to refine and stabilize motion capture processes are almost invariably driven by joint center estimates, and any errors in joint center calculation carry over and can be compounded when calculating joint kinematics. Unfortunately, accurate determination of joint centers is a complex task, primarily due to measurements being contaminated by soft-tissue artifact (STA). This paper proposes a novel approach to joint center estimation implemented via sequential applic...

  17. Polymer compound

    NARCIS (Netherlands)

    1995-01-01

    A Polymer compound comprising a polymer (a) that contains cyclic imidesgroups and a polymer (b) that contains monomer groups with a 2,4-diamino-1,3,5-triazine side group. According to the formula (see formula) whereby themole percentage ratio of the cyclic imides groups in the polymer compoundwith

  18. Mesoionic Compounds

    Indian Academy of Sciences (India)

    Organic Chemistry. Kamatak University,. Dharwad. Her research interests are synthesis, reactions and synthetic utility of sydnones. She is currently working on electrochemical and insecticidal/antifungal activities for some of these compounds. Keywords. Aromaticity, mesoionic hetero- cycles, sydnones, tandem re- actions.

  19. Compound odontoma

    Directory of Open Access Journals (Sweden)

    Monica Yadav

    2012-01-01

    Full Text Available Odontomas have been extensively reported in the dental literature, and the term refers to tumors of odontogenic origin. Though the exact etiology is still unknown, the postulated causes include: local trauma, infection, inheritance and genetic mutation. The majority of the lesions are asymptomatic; however, may be accompanied with pain and swelling as secondary complaints in some cases. Here, we report a case of a compound odontome in a 14 year old patient.

  20. Joint Replacement (Finger and Wrist Joints)

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Joint Replacement Email to a friend * required fields ...

  1. Hip joint injection

    Science.gov (United States)

    ... medicine into the joint. The provider uses a real-time x-ray (fluoroscopy) to see where to place ... Wakefield RJ. Arthrocentesis and injection of joints and soft tissue. In: Firestein GS, Budd RC, Gabriel SE, ...

  2. Sacroiliac joint pain - aftercare

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000610.htm Sacroiliac joint pain - aftercare To use the sharing features on this page, please enable JavaScript. The sacroiliac joint (SIJ) is a term used to describe ...

  3. Reliability of Tubular Joints

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Thoft-Christensen, Palle

    In this paper the preliminary results obtained by tests on tubular joints are presented. The joints are T-joints and the loading is static. It is the intention in continuation of these tests to perform tests on other types of joints (e.g. Y-joints) and also with dynamic loading. The purpose...... of the test is partly to obtain empirical data for the ultimate load-carrying capacity of tubular T-joints and partly to obtain some experience in performing tests with tubular joints. It is well known that tubular joints are usually designed in offshore engineering on the basis of empirical formulas obtained...... by experimental test results. Therefore, there is a need for performing experimental tests in this area....

  4. Hip joint replacement - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100006.htm Hip joint replacement - series—Normal anatomy To use the ... to slide 5 out of 5 Overview The hip joint is made up of two major parts: ...

  5. Design of mechanical joints

    CERN Document Server

    Blake, Alexander

    2018-01-01

    A cornerstone publication that covers the basic principles and practical considerations of design methodology for joints held by rivets, bolts, weld seams, and adhesive materials, Design of Mechanical Joints gives engineers the practical results and formulas they need for the preliminary design of mechanical joints, combining the essential topics of joint mechanics...strength of materials...and fracture control to provide a complete treatment of problems pertinent to the field of mechanical connections.

  6. Managing Joint Production Motivation

    DEFF Research Database (Denmark)

    Lindenberg, Siegwart; Foss, Nicolai Juul

    2011-01-01

    We contribute to the microfoundations of organizational performance by proffering the construct of joint production motivation. Under such motivational conditions individuals see themselves as part of a joint endeavor, each with his or her own roles and responsibilities; generate shared...... representations of actions and tasks; cognitively coordinate cooperation; and choose their own behaviors in terms of joint goals. Using goal-framing theory, we explain how motivation for joint production can be managed by cognitive/symbolic management and organizational design....

  7. Magnesium compounds

    Science.gov (United States)

    Kramer, D.A.

    2007-01-01

    Seawater and natural brines accounted for about 52 percent of U.S. magnesium compounds production in 2006. Dead-burned magnesia was produced by Martin Marietta Magnesia Specialties from well brines in Michigan. Caustic-calcined magnesia was recovered from sea-water by Premier Chemicals in Florida; from well brines in Michigan by Martin Marietta and Rohm and Haas; and from magnesite in Nevada by Premier Chemicals. Intrepid Potash-Wendover and Great Salt Lake Minerals recovered magnesium chloride brines from the Great Salt Lake in Utah. Magnesium hydroxide was produced from brucite by Applied Chemical Magnesias in Texas, from seawater by SPI Pharma in Delaware and Premier Chemicals in Florida, and by Martin Marietta and Rohm and Haas from their operations mentioned above. About 59 percent of the magnesium compounds consumed in the United States was used for refractories that are used mainly to line steelmaking furnaces. The remaining 41 percent was consumed in agricultural, chemical, construction, environmental and industrial applications.

  8. Organic astatine compounds, their preparation and properties

    Energy Technology Data Exchange (ETDEWEB)

    Vasaros, L; Berei, K

    1985-01-01

    Aromatic astatine compounds of possible medical application were prepared by high energy substitutions, by astatine-halogen, and by electrophil astatine-hydrogen substitutions at the Joint Institute of Nuclear Researches, Dubna. Physico-chemical properties of organic astatine compounds such as boiling point and evaporation heat, and the refraction and dissociation energy of carbon-astatine bonds were determined experimentally by gas chromatography. The results are compared with extrapolated data. (V.N.). 41 refs.; 7 figs.; 5 tables.

  9. Compound odontoma

    Directory of Open Access Journals (Sweden)

    José Marcelo Vargas Pinto

    2008-01-01

    Full Text Available Odontomas are the most common types of odontogenic tumors, as they are considered more as a developmental anomaly (hamartoma than as a true neoplasia. The aim of the present study is to describe a clinical case of compound odontoma, analyzing its most commonsigns, its region of location, the decade of life and patient’s gender, disorders that may occur as well as the treatment proposed. In order to attain this objective, the method was description of the present clinical case and bibliographic revision, arriving at the result that the treatment for this type of lesion invariably is surgical removal (enucleation and curettage and the prognosis is excellent. The surgical result was followed up in the post-operative period by radiographic exam, and it was possible to conclude that there was complete cicatrization and tissue repair.

  10. Magnesium compounds

    Science.gov (United States)

    Kramer, D.A.

    2012-01-01

    Seawater and natural brines accounted for about 57 percent of magnesium compounds produced in the United States in 2011. Dead-burned magnesia was produced by Martin Marietta Magnesia Specialties LLC from well brines in Michigan. Caustic-calcined magnesia was recovered from seawater by Premier Magnesia LLC in Florida, from well brines in Michigan by Martin Marietta and from magnesite in Nevada by Premier Magnesia. Intrepid Potash Wendover LLC and Great Salt Lake Minerals Corp. recovered magnesium chloride brines from the Great Salt Lake in Utah. Magnesium hydroxide was produced from seawater by SPI Pharma Inc. in Delaware and Premier Magnesia in Florida, and by Martin Marietta from its brine operation in Michigan.

  11. APPLICATION PROSPECTS OF THREADED JOINT OF ARMATURE

    Directory of Open Access Journals (Sweden)

    A. V. Radkevych

    2014-06-01

    Full Text Available Purpose. One of the main technological operations of buildings construction on the basis of monolithic frame systems is the production of mesh reinforcement. The current interest is the new ways specification of advanced bonding armature techniques without reliability weakness and design of the building in whole, as well as the finding of use prospects of screw-threaded joint of armature as the most technological and economic method of re-bars joints. Methodology. Advantages and disadvantages analysis of existing rebar compound technologies was implemented by couplings of different types and constructions. The most promising vertical constructions for the vertical bars joints in frameworks were determined. Findings. Researches of existing technologies of rebar joints by the couplings of different construction were carried out. The installation method of mesh reinforcement of vertical structural elements with the use of the special catching devices was developed. It allows considerably accelerating installation of mesh reinforcement. Originality. Regularity of labor intensiveness change of mesh reinforcement installation of columns at armature joint in vertical position by threaded couplings with the help of catching devices using special construction was determined. This allows substantially reducing the labor expenditures during installation of these elements. Dependency of labor intensiveness and cost of lap welding armature joints, by tub-seam welding and by thread coupling depending on its diameter was designated. Regularity of labor intensiveness changes of installation at armature joints by different methods taking into account preparatory works was defined. Practical value. The analysis of mechanical armature joints techniques was conducted. It will allow selecting methods of armature joints to increase the speed of construction works more economical and effective.

  12. Mechanics of Suture Joints

    Science.gov (United States)

    Li, Yaning; Song, Juha; Ortiz, Christine; Boyce, Mary; Ortiz Group/DMSE/MIT Team; Boyce Group/ME/MIT Team

    2011-03-01

    Biological sutures are joints which connect two stiff skeletal or skeletal-like components. These joints possess a wavy geometry with a thin organic layer providing adhesion. Examples of biological sutures include mammalian skulls, the pelvic assembly of the armored fish Gasterosteus aculeatus (the three-spined stickleback), and the suture joints in the shell of the red-eared slider turtle. Biological sutures allow for movement and compliance, control stress concentrations, transmit loads, reduce fatigue stress and absorb energy. In this investigation, the mechanics of the role of suture geometry in providing a naturally optimized joint is explored. In particular, analytical and numerical micromechanical models of the suture joint are constructed. The anisotropic mechanical stiffness and strength are studied as a function of suture wavelength, amplitude and the material properties of the skeletal and organic components, revealing key insights into the optimized nature of these ubiquitous natural joints.

  13. RILEM International Symposium on Materials and Joints in Timber Structures

    CERN Document Server

    Reinhardt, H-W; Garrecht, Harald

    2014-01-01

    This book contains the contributions from the RILEM International Symposium on Materials and Joints in Timber Structures that was held in Stuttgart, Germany from October 8 to 10, 2013. It covers recent developments in the materials and the joints used in modern timber structures. Regarding basic wooden materials, the contributions highlight the widened spectrum of products comprising cross-laminated timber, glulam and LVL from hardwoods and block glued elements. Timber concrete compounds, cement bonded wood composites and innovative light-weight constructions represent increasingly employed alternatives for floors, bridges and facades. With regard to jointing technologies, considerable advances in both mechanical connections and glued joints are presented. Self-tapping screws have created unprecedented options for reliable, strong as well as ductile joints and reinforcement technologies. Regarding adhesives, which constitute the basis of the jointing/laminating technology of modern timber products, extended o...

  14. Expansion joints for LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Dzenus, M.; Hundhausen, W.; Jansing, W.

    1979-10-15

    This discourse recounts efforts put into the SNR-2 project; specifically the development of compensation devices. The various prototypes of these compensation devices are described and the state of development reviewed. The expansion joints were developed on the basis of specific design criteria whereby differentiation is made between expansion joints of small and large nominal diameter. Expansion joints for installation in the sodium-filled primary piping are equipped with safety bellows in addition to the actual working bellows.

  15. Isotopically modified compounds

    International Nuclear Information System (INIS)

    Kuruc, J.

    2009-01-01

    In this chapter the nomenclature of isotopically modified compounds in Slovak language is described. This chapter consists of following parts: (1) Isotopically substituted compounds; (2) Specifically isotopically labelled compounds; (3) Selectively isotopically labelled compounds; (4) Non-selectively isotopically labelled compounds; (5) Isotopically deficient compounds.

  16. JET Joint Undertaking

    International Nuclear Information System (INIS)

    Keen, B.E.

    1987-03-01

    The paper presents the progress report of the Joint European Torus (JET) Joint Undertaking, 1986. The report contains a survey of the scientific and technical achievements on JET during 1986; the more important articles referred to in this survey are reproduced as appendices to this Report. The last section discusses developments which might improve the overall performance of the machine. (U.K.)

  17. 13. Sacroiliac joint pain

    NARCIS (Netherlands)

    Vanelderen, P.; Szadek, K.M.; Cohen, S.P.; Witte, J.; Lataster, A.; Patijn, J.; Mekhail, N.; van Kleef, M.; van Zundert, J.

    2010-01-01

    The sacroiliac joint accounts for approximately 16% to 30% of cases of chronic mechanical low back pain. Pain originating in the sacroiliac joint is predominantly perceived in the gluteal region, although pain is often referred into the lower and upper lumbar region, groin, abdomen, and/ or lower

  18. Transversely Compressed Bonded Joints

    DEFF Research Database (Denmark)

    Hansen, Christian Skodborg; Schmidt, Jacob Wittrup; Stang, Henrik

    2012-01-01

    The load capacity of bonded joints can be increased if transverse pressure is applied at the interface. The transverse pressure is assumed to introduce a Coulomb-friction contribution to the cohesive law for the interface. Response and load capacity for a bonded single-lap joint was derived using...

  19. Joint Newspaper Operating Agreements.

    Science.gov (United States)

    Parsons, Marie

    The number of competing daily newspapers in American cities has dwindled until only about 50 cities boast two papers. Of the newspapers in those cities, 23 now maintain separate editorial operations but have joint printing, advertising, and circulation departments. The concept of joint operation is 50 years old, dating from the Depression years…

  20. Joint Hub Network Development

    NARCIS (Netherlands)

    Cruijssen, F.C.A.M.; Borm, P.E.M.; Dullaert, W.; Hamers, H.J.M.

    2007-01-01

    This paper introduces a framework for joint hub network development. Building a joint physical hub for transhipment of goods is expensive and therefore involves considerable risks for the cooperating companies. In a practical setting, it is unlikely that an entire network will be built at once.

  1. Elbow joint instability

    DEFF Research Database (Denmark)

    Olsen, Bo Sanderhoff; Henriksen, M G; Søjbjerg, Jens Ole

    1994-01-01

    The effect of simultaneous ulnar and radial collateral ligament division on the kinematics of the elbow joint is studied in a cadaveric model. Severance of the anterior part of the ulnar collateral ligament and the annular ligament led to significant elbow joint instability in valgus and varus...

  2. Bistable Articulated Joint

    Science.gov (United States)

    Graighead, Norwood D., II; Preliasco, R. J.; Hult, T. D.

    1986-01-01

    Joint with four-bar-linkage geometry has following attributes: Springs to fully extended fully folded positions. Automatically locks in its extended position. Joint combines zero backlash, positive locking, and centerline pivoting. Used in folding tool handles, portable antenna booms, and many other deployable structures.

  3. MP Joint Arthritis

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy MP Joint Arthritis Email to a friend * required ...

  4. Creep of timber joints

    NARCIS (Netherlands)

    Van de Kuilen, J.W.G.

    2008-01-01

    A creep analysis has been performed on nailed, toothed-plates and split-ring joints in a varying uncontrolled climate. The load levels varied between 30% and 50% of the average ultimate short term strength of these joints, tested in accordance with ISO 6891. The climate in which the tests were

  5. MR diagnosis of temporomandibular joint. A study of joint effusion

    International Nuclear Information System (INIS)

    Kaneda, Takashi; Yamashiro, Mitsuaki; Ozawa, Kaoru; Suzuki, Hiromi; Okada, Hiroyuki; Yamamoto, Hirotsugu

    1998-01-01

    The purposes of this study were to evaluate the relationship between correlation of MR joint effusion of the temporomandibular joint and disk position, to evaluate the relationship between joint effusion and aging, and to assess the frequency of MR joint effusion of bilateral temporomandibular joints. The temporomandibular joints of 192 patients with clinical symptoms of temporomandibular joint disorders were imaged bilaterally using high field, surface-coil MR imaging. Oblique sagittal and coronal proton density-weighted and T2-weighted images were obtained. Imaging findings of joint effusion were correlated with disk position, aging, and bilateral temporomandibular joints. MR showed effusion in 4% of the joints with normal superior disk position, 36% of the joints with disk displacement with reduction, and 45% of the joints with disk displacement without reduction. There were significant differences in the incidence of joint effusion between normal disk position and anterior disk displacement with or without reduction. Younger patients less than 40 years were significant higher the incidence of joint effusion than those of older patients. A significant association was seen between joint effusion and aging. MR showed effusion in 17% of the unilateral temporomandibular joint, 24% of the bilateral temporomandibular joints. There was no significant difference between unilateral and bilateral case. These results indicated that joint effusion using MR imaging was associated with varied temporomandibular joint pathologic states. (author)

  6. Generalised joint hypermobility and knee joint hypermobility

    DEFF Research Database (Denmark)

    Junge, Tina; Henriksen, Peter; Hansen, Sebrina

    2018-01-01

    . Respondents with GJHk and KJH reported lower HRQoL. CONCLUSION: GJHk and KJH were frequently reported in the Danish adult population, mostly in women. Respondents with GJHk and KJH were two times more likely to report knee joint-related symptoms such as pain, reduced performance of usual activity and lower...

  7. Joint Electromagnetic Spectrum Management Operations

    Science.gov (United States)

    2012-03-20

    promulgate command-specific policy and guidance for EMS use, the joint restricted frequency list (JRFL) process, the joint communications–electronics...joint communications–electronics operating instructions (JCEOI) and joint restricted frequency list (JRFL). Examples of FM include providing the...joint restricted frequency list Figure III-4. Joint Frequency Management Office Spectrum Management Process Chapter III III-10 JP 6-01 assignments

  8. Rubber compounding and processing

    CSIR Research Space (South Africa)

    John, MJ

    2014-06-01

    Full Text Available This chapter presents an overview on the compounding and processing techniques of natural rubber compounds. The introductory portion deals with different types of rubbers and principles of rubber compounding. The primary and secondary fillers used...

  9. Joint Quantum Institute

    Data.gov (United States)

    Federal Laboratory Consortium — The Joint Quantum Institute (JQI) is pursuing that goal through the work of leading quantum scientists from the Department of Physics of the University of Maryland...

  10. Temporomandibular Joint Disorder

    Science.gov (United States)

    ... Baby Bottle Tooth Decay? Pacifiers Have Negative and Positive Effects What is Dental Amalgam (Silver Filling)? Check Menstrual Calendar for Tooth Extraction Temporomandibular Joint Disorder Learn what those dental words mean. Check out how your teeth and mouth ...

  11. Hip joint replacement

    Science.gov (United States)

    Hip arthroplasty; Total hip replacement; Hip hemiarthroplasty; Arthritis - hip replacement; Osteoarthritis - hip replacement ... Your hip joint is made up of 2 major parts. One or both parts may be replaced during surgery: ...

  12. Knee joint replacement

    Science.gov (United States)

    ... to make everyday tasks easier. Practice using a cane, walker , crutches , or a wheelchair correctly. On the ... ask your doctor Knee joint replacement - discharge Preventing falls Preventing falls - what to ask your doctor Surgical ...

  13. Concrete pavement joint deterioration.

    Science.gov (United States)

    2015-12-01

    Concrete pavements are an important part of our national infrastructure. In recent years the relatively small number of reported joints deteriorating prematurely in concrete pavements around Indiana has increased. Changes over the past 45 years in IN...

  14. Sacroiliac joint dysfunction.

    Science.gov (United States)

    Ilaslan, Hakan; Arslan, Ahmet; Koç, Omer Nadir; Dalkiliç, Turker; Naderi, Sait

    2010-07-01

    Sacroiliac joint dysfunction is a disorder presenting with low back and groin pain. It should be taken into consideration during the preoperative differential diagnosis of lumbar disc herniation, lumbar spinal stenosis and facet syndrome. Four cases with sacroiliac dysfunction are presented. The clinical and radiological signs supported the evidence of sacroiliac dysfunction, and exact diagnosis was made after positive response to sacroiliac joint block. A percutaneous sacroiliac fixation provided pain relief in all cases. The mean VAS scores reduced from 8.2 to 2.2. It is concluded that sacroiliac joint dysfunction diagnosis requires a careful physical examination of the sacroiliac joints in all cases with low back and groin pain. The diagnosis is made based on positive response to the sacroiliac block. Sacroiliac fixation was found to be effective in carefully selected cases.

  15. Joint Hub Network Development

    OpenAIRE

    Cruijssen, F.C.A.M.; Borm, P.E.M.; Dullaert, W.; Hamers, H.J.M.

    2007-01-01

    This paper introduces a framework for joint hub network development. Building a joint physical hub for transhipment of goods is expensive and therefore involves considerable risks for the cooperating companies. In a practical setting, it is unlikely that an entire network will be built at once. Rather, the partners will have a more cautious attitude and build the hub facilities one-by-one. In the proposed framework, every time a new hub is introduced, partners will have the opportunity to dec...

  16. Prosthetic Joint Infections

    Science.gov (United States)

    Aslam, Saima; Darouiche, Rabih O.

    2012-01-01

    Prosthetic joint infections represent a major therapeutic challenge for both healthcare providers and patients. This paper reviews the predisposing factors, pathogenesis, microbiology, diagnosis, treatment and prophylaxis of prosthetic joint infection. The most optimal management strategy should be identified based on a number of considerations including type and duration of infection, antimicrobial susceptibility of the infecting pathogen, condition of infected tissues and bone stock, patient wishes and functional status. PMID:22847032

  17. Benign joint hypermobility syndrome

    Directory of Open Access Journals (Sweden)

    Iwona Słowińska

    2014-11-01

    Full Text Available Benign joint hypermobility syndrome (BJHS, commonly known as loose ligament syndrome, is a non-inflammatory rheumatic condition. It is characterised by a greater than normal range of motion of the joints of the limbs and spine. The prevalence of the syndrome in preschool-age children is estimated to be between 2% and 30%, depending on ethnic background (with higher prevalence in Asian and African populations, occurring most often in families with a history of the condition and more frequently in girls. This paper presents a case report of a 12-year-old girl. A broad differential diagnostic approach to recurrent joint inflammation with joint effusion and pain made it possible to establish a diagnosis of benign joint hypermobility syndrome. The child met the Brighton criteria; her Beighton score was 7 out of 9. Patient education aimed at eliminating abnormal joint movement and an appropriate rehabilitation programme play key roles in the treatment of BJHS.

  18. Evaluation of the dose-response and fate in the lung and pleura of chrysotile-containing brake dust compared to chrysotile or crocidolite asbestos in a 28-day quantitative inhalation toxicology study.

    Science.gov (United States)

    Bernstein, D M; Toth, B; Rogers, R A; Sepulveda, R; Kunzendorf, P; Phillips, J I; Ernst, H

    2018-04-26

    This study provides an understanding of the biokinetics and potential toxicology in the lung and pleura following inhalation of brake-dust (brakes manufactured with chrysotile). The design included a 28-day repeated multi-dose inhalation exposure (6 h/d, 5 d/wk, 4 wks) followed by 28-days without exposure. Fiber control groups included a similar grade chrysotile as used in the brakes and a commercial crocidolite asbestos. Aerosol fiber distributions of the chrysotile and crocidolite were similar (fiber-length > 20 μm/cm 3 : Chrysotile-low/high 42/62; Crocidolite-low/high 36/55; WHO-fibers/cm 3 : Chrysotile-low/high 192/219; Crocidolite-low/high 211/255). The total number of aerosol particles/cm 3 in the brake-dust was similar to that in the chrysotile (Brake-dust 710-1065; Chrysotile 532-1442). Brake-dust at particle exposure levels equal to or greater than chrysotile or crocidolite caused no indication of microgranulomas, epithelial hyperplasia, or fibrosis (Wagner score brake-dust and chrysotile-HD groups or in thickness of visceral or parietal pleural. The crocidolite exposure resulted in extensive inflammatory response, collagen development and adhesions between the visceral and parietal surfaces with double the surface thickness. These results provide essential information for the design of a subsequent subchronic study. Copyright © 2018. Published by Elsevier Inc.

  19. Jointness for the Rest of Us: Reforming Joint Professional Development

    Science.gov (United States)

    2016-06-10

    transferred to the Joint Staff. 13 DOD’s instinct to “overly centralize planning, organization, and management.”20 The authors contend that this...2. 3 John F. Schank and others, Who is Joint? Reevaluating the Joint Duty Assignment List : A Study Prepared for the Joint Staff, by the RAND...and code those billets as such. Once identified, DOD must expand the Joint Duty Assignment List (JDAL) to include billets that offer enlisted personnel

  20. Acromioclavicular joint separation

    Directory of Open Access Journals (Sweden)

    Devan Pandya, BS

    2018-04-01

    Full Text Available History of present illness: A 30-year-old male was brought in by ambulance to the emergency department as a trauma activation after a motorcycle accident. The patient was the helmeted rider of a motorcycle traveling at an unknown speed when he lost control and was thrown off his vehicle. He denied loss of consciousness, nausea, or vomiting. The patient’s vital signs were stable and his only complaint was pain around his left shoulder. On exam, the patient had a prominent left clavicle without skin compromise. He had adequate range of motion in the left shoulder with moderate pain, and his left upper extremity was neurovascularly intact. Significant findings: Plain films of the left shoulder showed elevation of the left clavicle above the acromion. There was an increase in the acromioclavicular (AC and coracoclavicular (CC distances (increased joint distances marked with red and blue arrows, respectively. A normal AC joint measures 1-3 mm whereas a normal CC distance measures 11-13 mm.1 The injury was classified as a Rockwood type III AC joint separation. Discussion: The AC joint is a synovial joint between an oval facet on the acromion and a similar facet on the distal end of the clavicle. Horizontal stability is provided by the AC joint while axial stability is provided by the CC joint.2,3 AC joint injuries account for about 9%-12% of shoulder girdle injuries, and the most common mechanism is direct trauma.4,5 Initial evaluation with imaging includes plain films with three views: the anterior-posterior (AP view with the shoulder in internal and external rotation as well as an axillary, or scapula-Y view (sensitivity 40%, specificity 90% for all films.6,7 AC joint injuries are classified by the Rockwood system.8 Type I involves a sprain or incomplete tear of the AC ligaments with an intact CC ligament. The AC joint appears normal on X-ray, but can become widened with stress, achieved by having the patient hold a 10-15 pound weight from each

  1. Forming a multinational joint venture

    International Nuclear Information System (INIS)

    Bhatia, N.K.; Garb, R.H.; Statton, T.D.

    1990-01-01

    This paper discusses the basis and mechanics for forming a multinational joint venture. The topics of the paper include the motivations for a joint venture, selection of the appropriate co-venturer, management of the multinational joint venture, and the joint venture agreement. The authors state that a joint venture is not applicable or desirable in all instances and to be successful, must be carefully planned

  2. Facet joint syndrome

    International Nuclear Information System (INIS)

    Zigrai, M.; Zakovic, J.; Brezinova, M.; Pavlovicova, M.

    2002-01-01

    It is the purpose of the study to demonstrate the clinical relevance of degenerative changes in the facet joint of patients with low back pain irradiating to the lower extremities, and discuss some problems relating to diagnosis and different diagnosis. 119 patients presenting the listed bellow syndromes are covered by the study: scoliosis, polytopic pain vertebral syndrome, paresis and history of trauma. all patients undergo comprehensive neurological examination with special attention focused on the spine: CT and plain x-rays are taken of the lumbosacral segment to assess the condition of the facet joints. The neurological examination demonstrates in all cases pain syndrome in the lumbar spine referred to one or both lower extremities. In 56% it is a matter of persisting pain, and in 44% - recurrent. More than half of the patients complain of sacroiliac (SI) dislocation and palpatory pain. Unilateral or bilateral degenerative changes are documented by imaging studies in all patients, including: subchondral thickening, osteopathy narrowing the lateral or central part of the spinal canal with ensuing nerve root compression. The lumbosacral zygoapophyseal joints are source of pseudoradicular pain. A correlation between clinical picture and GT changes is noted in all patients with facet joint syndrome. CT is an indispensable method in diagnosing facet joint syndrome. (authors)

  3. Temporomandibular joint examination reviewed

    Directory of Open Access Journals (Sweden)

    L. Guarda Nardini

    2011-09-01

    Full Text Available The temporo-mandibular joint (TMJ it’s a joint closely related to the skull base, the spine, and the jaws; all these anatomical structures must be taken in consideration when evaluating pain involving the tmj. In order to detect patients affected by pathology or dysfunctions of the tmj, physical examination is of great value in orienting the diagnosis. Inspection must consider the symmetry of the body, the dental status and the type of occlusion. Palpation is a way to assess contractiont involving the muscles of the masticatory system and of the neck. Auscultation, based on articular noise provides means to determine whether we are dealing with degeneration of the joint or a dislocation of the intrarticular disc. In order to confirm the diagnosis obtained with the clinical evaluation, it’s useful to perform imaging techniques as opt, tomography and TC of the tmj and electromyokineosiography – index of the mandibular functionality and of the muscles status. MRI and dynamic MRI are among the non invasive exams which give the greatest amount of information, regarding the disc position and the joint degeneration. Arthroscopy is an invasive technique that allows early diagnosis of degeneration and is helpful to reveal early inflammatory processes of the joint.

  4. Distal radioulnar joint injuries

    Directory of Open Access Journals (Sweden)

    Binu P Thomas

    2012-01-01

    Full Text Available Distal radioulnar joint is a trochoid joint relatively new in evolution. Along with proximal radioulnar joint , forearm bones and interosseous membrane, it allows pronosupination and load transmission across the wrist. Injuries around distal radioulnar joint are not uncommon, and are usually associated with distal radius fractures,fractures of the ulnar styloid and with the eponymous Galeazzi or Essex_Lopresti fractures. The injury can be purely involving the soft tissue especially the triangular fibrocartilage or the radioulnar ligaments.The patients usually present with ulnar sided wrist pain, features of instability, or restriction of rotation. Difficulty in carrying loads in the hand is a major constraint for these patients. Thorough clinical examination to localize point of tenderness and appropriate provocative tests help in diagnosis. Radiology and MRI are extremely useful, while arthroscopy is the gold standard for evaluation. The treatment protocols are continuously evolving and range from conservative, arthroscopic to open surgical methods. Isolated dislocation are uncommon. Basal fractures of the ulnar styloid tend to make the joint unstable and may require operative intervention. Chronic instability requires reconstruction of the stabilizing ligaments to avoid onset of arthritis. Prosthetic replacement in arthritis is gaining acceptance in the management of arthritis.

  5. Formation of Exfoliation Joints

    Science.gov (United States)

    Martel, S. J.

    2004-12-01

    The Earth's internal stresses interact with the topographic surface to affect many phenomena. Exfoliation joints, or sheeting joints, are widespread manifestations of this interaction. These opening-mode fractures form subparallel to the Earth's surface, bounding roughly concentric slabs of rock that resemble the layers of an onion. They occur worldwide in all major bedrock types, attain in-plane dimensions of hundreds of meters, exert a strong influence on groundwater flow, and help produce spectacular scenery, as in Yosemite National Park. The mechanism that causes them has been enigmatic. They are widely regarded as forming in response to "removal of overburden", but large fractures do not open in rocks merely by relieving a compressive stress. High fluid pressures, thermal effects, rock heterogeneity, and weathering also are rejected as primary causes of these fractures. Tensile stresses normal to the surface are required for large exfoliation fractures to open. Intriguingly, high surface-parallel compressive stresses are widely documented where exfoliation joints occur. Both numerical and analytical solutions for two-dimensional elastic bodies show that localized tensile stresses perpendicular to the ground surface must develop beneath certain topographies subject to strong compressive stresses parallel to the surface. This highly non-intuitive effect reflects the profound influence that topography can have on stresses near the surface of the Earth, and it can explain how exfoliation joints open. The theoretical results also indicate that exfoliation joint distributions could be used to infer the horizontal stresses near the Earth's surface.

  6. The temporomandibular joint

    International Nuclear Information System (INIS)

    Campbell, W.

    1984-01-01

    Whilst the temporomandibular joint is in many ways unique, it is subject to all the diseases and disorders found in joints in other parts of the human skeleton. By far the most common disorder is injury, followed by arthropathy, acute and chronic dislocations, ankylosis, and in rare instances, neoplasms. The diagnosis and management of the temporomandibular joint are the primary responsibility of the oral surgeon. Nevertheless, this anatomical region is an area in which the cooperation of medical and dental disciplines may be required for the satisfactory conclusion of treatment. The more so when the disease process involves either associated psychosomatic illness or malignancy. The mainstay of the diagnosis is a careful radiological examination of the joint. There exists a delicate relationship between the dentition, the muscles of mastication, and the temporomandibular articulation, which is controlled by arthrokinetic reflex activity of the branches of the 5th cranial nerve. Imbalance between one or more of the components of this integrated system frequently leads to disturbances in function. Pain-dysfunction disorders constitute the larger part of temporomandibular joint disturbances generally encountered

  7. Sanskrit Compound Processor

    Science.gov (United States)

    Kumar, Anil; Mittal, Vipul; Kulkarni, Amba

    Sanskrit is very rich in compound formation. Typically a compound does not code the relation between its components explicitly. To understand the meaning of a compound, it is necessary to identify its components, discover the relations between them and finally generate a paraphrase of the compound. In this paper, we discuss the automatic segmentation and type identification of a compound using simple statistics that results from the manually annotated data.

  8. Total ankle joint replacement.

    Science.gov (United States)

    2016-02-01

    Ankle arthritis results in a stiff and painful ankle and can be a major cause of disability. For people with end-stage ankle arthritis, arthrodesis (ankle fusion) is effective at reducing pain in the shorter term, but results in a fixed joint, and over time the loss of mobility places stress on other joints in the foot that may lead to arthritis, pain and dysfunction. Another option is to perform a total ankle joint replacement, with the aim of giving the patient a mobile and pain-free ankle. In this article we review the efficacy of this procedure, including how it compares to ankle arthrodesis, and consider the indications and complications. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  9. JOINT INVOLVEMENT IN SYPHILIS

    Directory of Open Access Journals (Sweden)

    T. I. Zlobina

    2016-01-01

    Full Text Available Joint involvement in syphilis has been considered as casuistry in recent years. At the same time, the high incidence of primary syphilis and the notified cases of late neurosyphilis may suggest that joint involvement in this disease is by no means always verified. Traditionally there are two forms of syphilitic arthritis: primary synovial (involving the articular membranes and sac and primary bone (involving the articular bones and cartilages ones. The paper describes the authors' clinical case of the primary bone form of articular syphilis in a 34-year-old man. 

  10. Expansion joints for LMFBR

    International Nuclear Information System (INIS)

    Dzenus, M.; Hundhausen, W.; Jansing, W.

    1980-01-01

    This discourse recounts efforts put into the SNR-2 project; specifically the development of compensation devices. The various prototypes of these compensation devices are described and the state of the development reviewed. Large Na (sodium)-heat transfer systems require a lot of valuable space if the component lay-out does not include compensation devices. So, in order to condense the spatial requirement as much as possible, expansion joints must be integrated into the pipe system. There are two basic types to suit the purpose: axial expansion joints and angular expansion joints. The expansion joints were developed on the basis of specific design criteria whereby differentiation is made between expansion joints of small and large nominal diameter. Expansion joints for installation in the sodium-filled primary piping are equipped with safety bellows in addition to the actual working bellows. Expansion joints must be designed and mounted in a manner to completely withstand seismic forces. The design must exclude any damage to the bellows during intermittent operations, that is, when sodium is drained the bellows' folds must be completely empty; otherwise residual solidified sodium could destroy the bellows when restarting. The expansion joints must be engineered on the basis of the following design data for the secondary system of the SNR project: working pressure: 16 bar; failure mode pressure: 5 events; failure mode: 5 sec., 28.5 bar, 520 deg. C; working temperature: 520 deg. C; temperature transients: 30 deg. C/sec.; service life: 200,000 h; number of load cycles: 10 4 ; material: 1.4948 or 1.4919; layer thickness of folds: 0.5 mm; angular deflection (DN 800): +3 deg. C or; axial expansion absorption (DN 600): ±80 mm; calculation: ASME class. The bellows' development work is not handled within this scope. The bellows are supplied by leading manufacturers, and warrant highest quality. Multiple bellows were selected on the basis of maximum elasticity - a property

  11. Sacroiliac Joint Interventions.

    Science.gov (United States)

    Soto Quijano, David A; Otero Loperena, Eduardo

    2018-02-01

    Sacroiliac joint (SIJ) pain is an important cause of lower back problems. Multiple SIJ injection techniques have been proposed over the years to help in the diagnosis and treatment of this condition. However, the SIJ innervation is complex and variable, and truly intra-articular injections are sometimes difficult to obtain. Different sacroiliac joint injections have shown to provide pain relief in patients suffering this ailment. Various techniques for intraarticular injections, sacral branch blocks and radiofrequency ablation, both fluoroscopy guided and ultrasound guided are discussed in this paper. Less common techniques like prolotherapy, platelet rich plasma injections and botulism toxin injections are also discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Prosthetic Joint Infection

    Science.gov (United States)

    Tande, Aaron J.

    2014-01-01

    SUMMARY Prosthetic joint infection (PJI) is a tremendous burden for individual patients as well as the global health care industry. While a small minority of joint arthroplasties will become infected, appropriate recognition and management are critical to preserve or restore adequate function and prevent excess morbidity. In this review, we describe the reported risk factors for and clinical manifestations of PJI. We discuss the pathogenesis of PJI and the numerous microorganisms that can cause this devastating infection. The recently proposed consensus definitions of PJI and approaches to accurate diagnosis are reviewed in detail. An overview of the treatment and prevention of this challenging condition is provided. PMID:24696437

  13. Imaging findings of charcot joint

    International Nuclear Information System (INIS)

    Meng Quanfei; Zhou Chunxiang; Chen Yingming; Jiang Bo

    2003-01-01

    Objective: To analyze the MRI characters of Charcot joint, and to evaluate the diagnostic value of X-ray, CT, and MRI on Charcot joint. Methods: Eight patients with 8 Charcot joints underwent X-ray, CT, and MR examinations. 6 of them had syringomyelia, 1 patient had injury of the spinal cord, and 1 case had diabetes. All 8 patients had sensory reduction or deficit in the sick extremities. Results: There were two types of Charcot joint, hypertrophic and atrophic. Radiographic and CT features of hypertrophic joint (n=3) showed hyperostotic osteosclerosis and mammoth osteophytes in the sick bones, periarticular ossification, and articular disorganization. Radiographic and CT features of atrophic joint (n=5) showed extensive bone resorption (destruction), periarticular debris, and articular disorganization. Main MRI features of Charcot joint included hydrarthrosis within joint capsule, thickened, loose, and elongated joint capsule with para-joint, peri-diaphysis, and inter-muscular extension in a pseudopodia pattern. The irregular joint capsule wall was presented as mild hypointensity on T 1 WI, slight hyper-intensity on T 2 WI, and was markedly enhanced after Gd-DTPA was administrated, which was considered as a characteristic manifestation of the lesion. Soft tissue mass containing hypo-intense stripes on both T 1 WI and T 2 WI was commonly noted adjacent to the involved joint. Conclusion: X-rays plain film is the first choice for the diagnosis of Charcot joint, and MRI is pretty useful in the diagnosis of Charcot joint

  14. Temporomandibular Joint Septic Arthritis

    Directory of Open Access Journals (Sweden)

    Gianfranco Frojo, MD

    2018-01-01

    Full Text Available Summary:. Infection of the temporomandibular joint (TMJ is a rare pediatric condition resulting from the introduction of pathogens into the joint by hematogenous seeding, local extension, or trauma. Early recognition of the typical signs and symptoms including fever, trismus, preauricular swelling, and TMJ region tenderness are critical in order to initiate further evaluation and prevent feared complications of fibrosis, ankylosis, abnormal facial structure, or persistence of symptoms. Contrast-enhanced computed tomography with ancillary laboratory analysis including erythrocyte sedimentation rate, C-reactive protein, and white blood cell count are beneficial in confirming the suspected diagnosis and monitoring response to therapy. Initial intervention should include empiric parenteral antibiotics, early mandibular mobilization, and joint decompression to provide synovial fluid for analysis including cultures. This report describes a case of TMJ bacterial arthritis in a healthy 6-year-old male who was promptly treated nonsurgically with intravenous antibiotics and localized needle joint decompression with return to normal function after completion of oral antibiotics and physical therapy.

  15. Joint-Use Libraries

    Science.gov (United States)

    Casstevens, Susan

    2017-01-01

    The joint-use library is a place where people of all ages, interests, and income levels can find items of interest at no personal cost. The mission of A. H. Meadows Public and High School Library in Midlothian, Texas, is to offer what other public libraries provide: educational and entertainment resources to a community. Yet, the staff also wants…

  16. Keyed shear joints

    DEFF Research Database (Denmark)

    Hansen, Klaus

    This report gives a summary of the present information on the behaviour of vertical keyed shear joints in large panel structures. An attemp is made to outline the implications which this information might have on the analysis and design of a complete wall. The publications also gives a short...

  17. Jointness: A Selected Bibliography

    Science.gov (United States)

    2007-08-01

    AD-A431-767) http://handle.dtic.mil/100.2/ADA431767 Lamb , William L. Moving beyond Goldwater-Nichols: The Case for Continued Reform of the DoD...in Support of the Joint Force’." Army Aviation 55 (May 2006): 22-24. Magnuson, Stew . "Turf Battles: Strategic Command’s Expanded Portfolio

  18. Gonococcal Prosthetic Joint Infection.

    Science.gov (United States)

    Gassiep, Ian; Gilpin, Bradley; Douglas, Joel; Siebert, David

    2017-01-01

    Neisseria gonorrhoea is a common sexually transmitted infection worldwide. Disseminated gonococcal infection is an infrequent presentation and rarely can be associated with septic arthritis. Incidence of this infection is rising, both internationally and in older age groups. We present the first documented case of N. gonorrhoea prosthetic joint infection which was successfully treated with laparoscopic debridement and antimicrobial therapy.

  19. An analysis of a joint shear model for jointed media with orthogonal joint sets

    International Nuclear Information System (INIS)

    Koteras, J.R.

    1991-10-01

    This report describes a joint shear model used in conjunction with a computational model for jointed media with orthogonal joint sets. The joint shear model allows nonlinear behavior for both joint sets. Because nonlinear behavior is allowed for both joint sets, a great many cases must be considered to fully describe the joint shear behavior of the jointed medium. An extensive set of equations is required to describe the joint shear stress and slip displacements that can occur for all the various cases. This report examines possible methods for simplifying this set of equations so that the model can be implemented efficiently form a computational standpoint. The shear model must be examined carefully to obtain a computationally efficient implementation that does not lead to numerical problems. The application to fractures in rock is discussed. 5 refs., 4 figs

  20. Temporomandibular joint space in children without joint disease

    International Nuclear Information System (INIS)

    Larheim, T.A.

    1981-01-01

    Bilateral assessment of the temporomandibular joint space in children without joint disease is reported. Twenty-eight children were examined with conventional radiography and 23 with tomography. High prevalence of asymmetric joint spaces with both techniques indicated that great care should be taken when using narrowing or widening of the joint space as a diagnostic criterion in children with juvenile rheumatoid arthritis. Other signs, such as restricted translation of the mandibular head, and clinical symptoms should be evaluated. (Auth.)

  1. Anaerobic prosthetic joint infection.

    Science.gov (United States)

    Shah, Neel B; Tande, Aaron J; Patel, Robin; Berbari, Elie F

    2015-12-01

    In an effort to improve mobility and alleviate pain from degenerative and connective tissue joint disease, an increasing number of individuals are undergoing prosthetic joint replacement in the United States. Joint replacement is a highly effective intervention, resulting in improved quality of life and increased independence [1]. By 2030, it is predicted that approximately 4 million total hip and knee arthroplasties will be performed yearly in the United States [2]. One of the major complications associated with this procedure is prosthetic joint infection (PJI), occurring at a rate of 1-2% [3-7]. In 2011, the Musculoskeletal Infectious Society created a unifying definition for prosthetic joint infection [8]. The following year, the Infectious Disease Society of America published practice guidelines that focused on the diagnosis and management of PJI. These guidelines focused on the management of commonly encountered organisms associated with PJI, including staphylococci, streptococci and select aerobic Gram-negative bacteria. However, with the exception of Propionibacterium acnes, management of other anaerobic organisms was not addressed in these guidelines [1]. Although making up approximately 3-6% of PJI [9,10], anaerobic microorganisms cause devastating complications, and similar to the more common organisms associated with PJI, these bacteria also result in significant morbidity, poor outcomes and increased health-care costs. Data on diagnosis and management of anaerobic PJI is mostly derived from case reports, along with a few cohort studies [3]. There is a paucity of published data outlining factors associated with risks, diagnosis and management of anaerobic PJI. We therefore reviewed available literature on anaerobic PJI by systematically searching the PubMed database, and collected data from secondary searches to determine information on pathogenesis, demographic data, clinical features, diagnosis and management. We focused our search on five commonly

  2. Development for dissimilar metal joint between stainless steel and zirconium by explosive bonding technique

    International Nuclear Information System (INIS)

    Onuma, Tsutomu; Matsumoto, Toshimi; Asano, Chooichi; Funamoto, Takao; Hirose, Yasuo; Sasada, Yasuhiro.

    1988-01-01

    Development of dissimilar metal joints between stainless steel and Zr for application to nuclear fuel reprocessing equipment was studied. Two dissimilar metal joints (Zr to SUS 304 L joint and its joint using Ta as insert metal) were made by the explosive bonding technique. After bonding, microstructure, tensile strength and corrosion test of dissimilar metal joints were investigated. The results indicated that: (1) The good dissimilar metal joint is obtained between stainless steel and Zr with a Ta insert metal by using explosive bonding technique. (2) A Ta insert metal retards a growth of intermetallic compounds at the bonding interface. (3) The strength of the dissimilar metal joint in this study is higher than that of Zr metal. Any local attack was not observed at the bonding interface after corrosion test. (author)

  3. Longitudinal joint specifications and performance.

    Science.gov (United States)

    2012-08-01

    Deterioration of longitudinal joints is widely recognized as one of the major factors contributing to failure of asphalt pavements. Finding : ways to improve the durability of longitudinal joints will lead to improved service lives and lower life cyc...

  4. Determination of Parachute Joint Factors using Seam and Joint Testing

    Science.gov (United States)

    Mollmann, Catherine

    2015-01-01

    This paper details the methodology for determining the joint factor for all parachute components. This method has been successfully implemented on the Capsule Parachute Assembly System (CPAS) for the NASA Orion crew module for use in determining the margin of safety for each component under peak loads. Also discussed are concepts behind the joint factor and what drives the loss of material strength at joints. The joint factor is defined as a "loss in joint strength...relative to the basic material strength" that occurs when "textiles are connected to each other or to metals." During the CPAS engineering development phase, a conservative joint factor of 0.80 was assumed for each parachute component. In order to refine this factor and eliminate excess conservatism, a seam and joint testing program was implemented as part of the structural validation. This method split each of the parachute structural joints into discrete tensile tests designed to duplicate the loading of each joint. Breaking strength data collected from destructive pull testing was then used to calculate the joint factor in the form of an efficiency. Joint efficiency is the percentage of the base material strength that remains after degradation due to sewing or interaction with other components; it is used interchangeably with joint factor in this paper. Parachute materials vary in type-mainly cord, tape, webbing, and cloth -which require different test fixtures and joint sample construction methods. This paper defines guidelines for designing and testing samples based on materials and test goals. Using the test methodology and analysis approach detailed in this paper, the minimum joint factor for each parachute component can be formulated. The joint factors can then be used to calculate the design factor and margin of safety for that component, a critical part of the design verification process.

  5. Swivel Joint For Liquid Nitrogen

    Science.gov (United States)

    Milner, James F.

    1988-01-01

    Swivel joint allows liquid-nitrogen pipe to rotate through angle of 100 degree with respect to mating pipe. Functions without cracking hard foam insulation on lines. Pipe joint rotates on disks so mechanical stress not transmitted to thick insulation on pipes. Inner disks ride on fixed outer disks. Disks help to seal pressurized liquid nitrogen flowing through joint.

  6. Joint audits - benefit or burden?

    DEFF Research Database (Denmark)

    Holm, Claus; Thinggaard, Frank

    a joint audit regime to a single auditor/voluntary joint audit regime. The dataset used in this paper has been collected for the full population of non-financial Danish companies listed on the Copenhagen Stock Exchange (CSE) in the years 2004 and 2005. We find that a majority of firms perceive joint...

  7. Joint International Accelerator School

    CERN Multimedia

    CERN Accelerator School

    2014-01-01

    The CERN and US Particle Accelerator Schools recently organised a Joint International Accelerator School on Beam Loss and Accelerator Protection, held at the Hyatt Regency Hotel, Newport Beach, California, USA from 5-14 November 2014. This Joint School was the 13th in a series of such schools, which started in 1985 and also involves the accelerator communities in Japan and Russia.   Photo courtesy of Alfonse Pham, Michigan State University.   The school attracted 58 participants representing 22 different nationalities, with around half from Europe and the other half from Asia and the Americas. The programme comprised 26 lectures, each of 90 minutes, and 13 hours of case study. The students were given homework each day and had an opportunity to sit a final exam, which counted towards university credit. Feedback from the participants was extremely positive, praising the expertise and enthusiasm of the lecturers, as well as the high standard and quality of their lectures. Initial dis...

  8. Posterolateral elbow joint instability

    DEFF Research Database (Denmark)

    Olsen, Bo Sanderhoff; Søjbjerg, Jens Ole; Nielsen, K K

    1998-01-01

    Thirty-five osteoligamentous elbows were included in a study on the kinematics of posterolateral elbow joint instability during the pivot shift test (PST) before and after separate ligament cuttings in the lateral collateral ligament complex (LCLC). Division of the annular ligament or the lateral...... ulnar collateral ligament caused no laxity during the PST. Division of the lateral collateral ligament caused maximal laxity of 4 degrees and 23 degrees during forced PST in valgus and external rotation (supination), respectively. Cutting of the LCLC at the ulnar or the humeral insertion was necessary...... for any PST stressed elbow joint laxity to occur. Total division of the LCLC induced a maximal laxity of 7.9 degrees and 37 degrees during forced PST in valgus and external rotation (supination), respectively. This study suggests the lateral collateral ligament to be the primary soft tissue constraint...

  9. JET Joint Undertaking

    International Nuclear Information System (INIS)

    Keen, B.E.; Lallia, P.; O'Hara, G.W.; Pollard, I.E.

    1987-06-01

    The paper presents the annual report of the Joint European Torus (JET) Joint Undertaking, 1986. The report is divided into two parts: a part on the scientific and technical programme of the project, and a part setting out the administration and organisation of the Project. The first part includes: a summary of the main features of the JET apparatus, the JET experimental programme, the position of the Project in the overall Euratom programme, and how JET relates to other large fusion devices throughout the world. In addition, the technical status of JET is described, as well as the results of the JET operations in 1986. The final section of the first part outlines the proposed future programme of JET. (U.K.)

  10. Peripheral degenerative joint diseases

    Directory of Open Access Journals (Sweden)

    Nilzio Antonio da Silva

    2008-03-01

    Full Text Available Osteoarthritis, a degenerative joint disease, is the most commonrheumatic disorder mainly in a geriatric population. Manifestationsare pain, stiffness and functional loss in the affected joint.According to etiology it is classifi ed as primary (or idiopathicand secondary. Some risk factors for disease development aregenetics, race, age, sex, obesity, occupational activities andarticular biomechanics. Pathogenesis is the same for any cause orlocalization, being catabolic alterations, with synthesis, inhibitionand reparing intent of the cartilage matrix. Metalloproteinases andcytokines (IL-1,IL-6,TNF-α actions promote infl ammatory reactionand cartilage degradation. Pain, the most important symptom,does not correlate with radiologic fi ndings. Peripheral osteoarthritisoccurs predominantly in the knee, hip and hand. Diagnosis is basedon clinical features, laboratorial tests and radiological changes.Rheumatological associations’ guidelines for treatment includenon-pharmacologic (education, physiotherapy, assistive devices,and pharmacologic (analgesics, anti-infl ammatory drugs therapyand surgery. Arthroplasty seems to work better than medicines, butshould be used if other treatments have failed.

  11. Joint Counterdrug Operations

    Science.gov (United States)

    1998-02-17

    Chapter II Joint Pub 3-07.4 cocaine HCL production. There are over 150 groups trafficking in cocaine, with cartels centered in Medellin and Cali. These...nontraditional mapping products and several digital mapping data bases for geological information and intelligence systems. • Defense Security Assistance Agency...variety of means. Dissemination means include personal contact, physical transfer or courier of hard copy textual and graphic materials, digital and

  12. Jet Joint Undertaking

    International Nuclear Information System (INIS)

    Keen, B.E.; O'Hara, G.W.; Pollard, I.E.

    1988-07-01

    The paper presents the Jet Joint Undertaking annual report 1987. A description is given of the JET and Euratom and International Fusion Programmes. The technical status of JET is outlined, including the development and improvements made to the system in 1987. The results of JET Operation in 1987 are described within the areas of: density effects, temperature improvements, energy confinement studies and other material effects. The contents also contain a summary of the future programme of JET. (U.K.)

  13. Joint Fire Support

    Science.gov (United States)

    2010-06-30

    intelligence application package for theater battle management core system ( TBMCS ) functionality at wing and squadron levels. The automated four... TBMCS , Joint Surveillance and Target Attack Radar System (Ground Control Station), and Global Command and Control System, as well as with Allied FA...The TBMCS is a force level integrated air C2 system. TBMCS provides hardware, software, and communications interfaces to support the preparation

  14. Australias Joint Approach

    Science.gov (United States)

    2015-09-01

    headquarters command and control architecture , including consideration of our suggestion of formalising the strategic J staff system for the support of... architecture … to support successful joint operations.”28 Our analysis involving consultation with a number of senior officers indicates that a more...transported armies into battle since ancient Egyptian times.57 The cooperation between the Royal Australian Navy (RAN) and the Australian Army began with

  15. Formation of tough composite joints

    International Nuclear Information System (INIS)

    Brun, M.K.

    1997-05-01

    Joints which exhibit tough fracture behavior were formed in a composite with a Si/SiC matrix reinforced with Textron SCS-6 fibers with either boron nitride or silicon nitride fiber coatings. In composites with BN coatings fibers were aligned uniaxially, while composites with Si 3 N 4 -coated fibers had a 0/90 degree architecture. Lapped joints (joints with overlapping fingers) were necessary to obtain tough behavior. Geometrical requirements necessary to avoid brittle joint failure have been proposed. Joints with a simple overlap geometry (only a few fingers) would have to be very long in order to prevent brittle failure. Typical failure in these joints is caused by a crack propagating along the interfaces between the joint fingers. Joints of the same overall length, but with geometry changed to be symmetric about the joint centerline and with an extra shear surface exhibited tough fractures accompanied with extensive fiber pullout. The initial matrix cracking of these joints was relatively low because cracks propagated easily through the ends of the fingers. Joints with an optimized stepped sawtooth geometry produced composite-like failures with the stress/strain curves containing an elastic region followed by a region of rising stress with an increase of strain. Increasing the fiber/matrix interfacial strength from 9 to 25 MPa, by changing the fiber coating, increased matrix cracking and ultimate strength of the composite significantly. The best joints had matrix cracking stress and ultimate strength of 138 and 240 MPa, respectively. Joint failure was preceded by multiple matrix cracking in the entire composite. The high strength of the joints will permit building of structures containing joints with only a minor reduction of design stresses

  16. Modeling knee joint endoprosthesis mode of deformation

    Science.gov (United States)

    Skeeba, V. Yu; Ivancivsky, V. V.

    2018-03-01

    The purpose of the work was to define the efficient design of the endoprosthesis, working in a multiple-cycle loading environment. Methodology and methods: triangulated surfaces of the base contact surfaces of endoprosthesis butt elements have been created using the PowerShape and SolidWorks software functional environment, and the assemblies of the possible combinations of the knee joint prosthetic designs have been prepared. The mode of deformation modeling took place in the multipurpose program complex ANSYS. Results and discussion: as a result of the numerical modeling, the following data were obtained for each of the developed knee joint versions: the distribution fields of absolute (total) and relative deformations; equivalent stress distribution fields; fatigue strength coefficient distribution fields. In the course of the studies, the following efficient design assembly has been established: 1) Ti-Al-V alloy composite femoral component with polymer inserts; 2) ceramic liners of the compound separator; 3) a Ti-Al-V alloy composite tibial component. The fatigue strength coefficient for the femoral component is 4.2; for the femoral component polymer inserts is 1.2; for the ceramic liners of the compound separator is 3.1; for the tibial component is 2.7. This promising endoprosthesis structure is recommended for further design and technological development.

  17. Laboratory characterization of rock joints

    International Nuclear Information System (INIS)

    Hsiung, S.M.; Kana, D.D.; Ahola, M.P.; Chowdhury, A.H.; Ghosh, A.

    1994-05-01

    A laboratory characterization of the Apache Leap tuff joints under cyclic pseudostatic and dynamic loads has been undertaken to obtain a better understanding of dynamic joint shear behavior and to generate a complete data set that can be used for validation of existing rock-joint models. Study has indicated that available methods for determining joint roughness coefficient (JRC) significantly underestimate the roughness coefficient of the Apache Leap tuff joints, that will lead to an underestimation of the joint shear strength. The results of the direct shear tests have indicated that both under cyclic pseudostatic and dynamic loadings the joint resistance upon reverse shearing is smaller than that of forward shearing and the joint dilation resulting from forward shearing recovers during reverse shearing. Within the range of variation of shearing velocity used in these tests, the shearing velocity effect on rock-joint behavior seems to be minor, and no noticeable effect on the peak joint shear strength and the joint shear strength for the reverse shearing is observed

  18. Microstructure evolution in dissimilar AA6060/copper friction stir welded joints

    Science.gov (United States)

    Kalashnikova, T. A.; Shvedov, M. A.; Vasilyev, P. A.

    2017-12-01

    Friction stir welding process has been applied for making a dissimilar copper/aluminum alloy joint. The grain microstructure and mechanical properties of the obtained joint were studied. The structure of the cross-section of the FSW compound was analyzed. The microstructural evolution of the joint was examined using optical microscopy. The mechanical properties of the intermetallic particles were evaluated by measuring the microhardness according to the Vickers method. The microhardness of the intermetallic particles was by a factor of 4 lower than that of the particles obtained by fusion welding. The results of the investigations enable using friction stir welding for making dissimilar joints.

  19. Evaluation of interfacial microstructures in dissimilar joints of aluminum alloys to steel using nanoindentation technique

    International Nuclear Information System (INIS)

    Ogura, Tomo; Hirose, Akio; Saito, Yuichi; Ueda, Keisuke

    2009-01-01

    The characteristics of interfacial microstructures with additional elements in dissimilar 6000 system aluminum/steel joints were basically evaluated using tensile test, EPMA, TEM and nanoindentation. For Si (and Cu)-added alloy (S1 and SC), EPMA analysis showed that Si (and Cu) was enrichment in the reaction layers, which were formed during diffusion bonding. SAED pattern clarified that the reaction compounds at the interface changed from AlFe intermetalic compounds to AlFeSi intermetalic compounds by Si addition. Nanoindentation technique was successfully applied to the interfacial microstructures to understand directly the nanoscopic mechanical properties in the interfacial microstructures. The hardness and Young's modulus of Al 3 Fe intermetalic compounds was lower than those of Al 2 Fe 5 intermetalic compounds. Moreover, the hardness and Young's modulus of AlFeSi(Cu) compounds were lower than those of Al 3 Fe, indicating that the crystal system changed from orthorhombic structure to cubic structure. Joint strength of SC/steel joints was higher than that of the aluminum alloy with no additional element (Base)/ steel joint, indicating that interfacial microstructure was modified by the addition of Si and Cu to the 6000 system aluminum alloy. These results suggest that the nanoscopic mechanical properties at the interface microstructures affect greatly the macroscopic deformation behavior of the aluminum /steel dissimilar joints.

  20. Temporomandibular joint motion

    International Nuclear Information System (INIS)

    Maeda, M.; Kawamura, Y.; Matsuda, T.; Itou, S.; Odori, T.; Ishii, Y.; Torizuka, K.

    1990-01-01

    This paper evaluates MR imaging with the therapeutic effect after splint therapy in internal derangement of the temporomandibular joint (TMJ). Fifteen patients (19 TMJs) with internal derangement of the TMJ and five normal volunteers (10 TMJs) were examined with sagittal T1-weighted spin-echo and gradient recalled acquisition in a steady state (GRASS) MR imaging. MR studies of the patients undergoing splint therapy were performed with an without splints. Pseudodynamic images of TMJ motion provide information that was not available from spin-echo T1-weighted images

  1. Joint Advisory Appeals Board

    CERN Multimedia

    2013-01-01

    The Joint Advisory Appeals Board has examined the internal appeal lodged by a former member of the personnel, a beneficiary of the CERN Pension Fund, against the calculation of his pension in the framework of the Progressive Retirement Programme.   The person concerned has not objected to the report of the Board and the final decision of the Director-General being brought to the attention of the members of the personnel. In application of Article R VI 1.18 of the Staff Regulations, these documents will therefore be available from 26 July to 11 August 2013 at the following link. HR Department Head Office

  2. JOINT ADVISORY APPEALS BOARD

    CERN Multimedia

    Human Resources Division

    2002-01-01

    The Joint Advisory Appeals Board was convened to examine the appeal lodged by Mr Luc Vos with regard to advancement. As the appellant has not objected, the report of the Board and the final decision of the Director-General are brought to the notice of the personnel in accordance with Article R VI 1.20 of the Staff Regulations. The relevant documents will therefore be posted on the notice boards of the Administration Building (N° 60) from 14 to 28 June 2002. Human Resources Division Tel. 74128

  3. Joint Advisory Appeals Board

    CERN Multimedia

    HR Department

    2008-01-01

    The Joint Advisory Appeals Board has examined the internal appeal lodged by a member of the personnel against the decision to grant him only a periodic one-step advancement for the 2006 reference year. The person concerned has not objected to the report of the Board and the final decision of the Director-General being brought to the attention of the members of the personnel. In application of Article R VI 1.18 of the Staff Regulations, these documents will therefore be posted on the notice board of the Main building (bldg. 500) from 1 September to 14 September 2008. Human Resources Department (73911)

  4. Joint Advisory Appeals Board

    CERN Multimedia

    2003-01-01

    The Joint Advisory Appeals Board was convened to examine the appeal lodged by Mr Poul Frandsen concerning his assimilation into the new career structure. As the appellant has not objected, the report of the Board and the final decision of the Director-General are brought to the notice of the personnel in accordance with Article R VI 1.20 of the Staff Regulations. The relevant documents will therefore be posted on the notice boards of the Administration Building (N° 60) from 13 to 24 January 2003. Human Resources Division Tel. 74128

  5. JOINT ADVISORY APPEALS BOARD

    CERN Multimedia

    Personnel Division

    1999-01-01

    The Joint Advisory Appeals Board was convened to examine the appeal lodged by Mr Joào Bento with regard to residential category. As the appellant has not objected, the recommendations of the Board and the final decision of the Director-General are brought to the notice of the personnel in accordance with Article RÊVIÊ1.20 of the Staff Regulations.The relevant documents will therefore be posted on the notice boards of the Administration Building (N¡ 60) from 29 October to 12 November 1999.Personnel DivisionTel. 74128

  6. Joint Advisory Appeals Board

    CERN Multimedia

    HR Department

    2006-01-01

    The Joint Advisory Appeals Board was convened to examine an appeal lodged by a member of the personnel with regard to advancement. The person concerned has requested that the report of the Board and the final decision of the Director-General be brought to the notice of the personnel in accordance with Article R VI 1.20 of the Staff Regulations. The relevant documents will therefore be posted on the notice boards of the Administration Building (No. 60) from 24 March to 10 April 2006. Human Resources Department Tel. 74128

  7. Joint Advisory Appeals Board

    CERN Multimedia

    HR Department

    2007-01-01

    The Joint Advisory Appeals Board was convened to examine an internal appeal lodged by a member of the personnel with regard to the decision not to grant him an indefinite contract. The person concerned has requested that the report of the Board and the final decision of the Director-General be brought to the notice of the members of the personnel, in accordance with Article R VI 1.18 of the Staff Regulations. The relevant documents will therefore be posted on the notice board of the Main building (Bldg. 60) from 24 September to 7 October 2007. Human Resources Department

  8. JOINT ADVISORY APPEALS BOARD

    CERN Multimedia

    Human Resources Division

    2001-01-01

    The Joint Advisory Appeals Board was convened to examine the appeal lodged by Mr Olivier Francis Martin with regard to indefinite contract. As the appellant has not objected, the report of the Board and the final decision of the Director-General are brought to the notice of the personnel in accordance with Article R VI 1.20 of the Staff Regulations. The relevant documents will therefore be posted on the notice boards of the Administration Building (N° 60) from 8 to 25 June 2001.

  9. JOINT ADVISORY APPEALS BOARD

    CERN Multimedia

    Human Resources Division

    2002-01-01

    The Joint Advisory Appeals Board was convened to examine the appeal lodged by Mr Jack Blanchard with regard to 'non recognition of specific functions'. As the appellant has not objected, the report of the Board and the final decision of the Director-General are brought to the notice of the personnel in accordance with Article R VI 1.20 of the Staff Regulations. The relevant documents will therefore be posted on the notice boards of the Administration Building (N° 60) from 12th to 26th April 2002. Human Resources Division Tel. 74128

  10. Joint Advisory Appeals Board

    CERN Multimedia

    2003-01-01

    The Joint Advisory Appeals Board was convened to examine the appeal lodged by Mrs Judith Igo-Kemenes concerning the application of procedures foreseen by Administrative Circular N§ 26 (Rev. 3). As the appellant has not objected, the report of the Board and the final decision of the Director-General are brought to the notice of the personnel in accordance with Article R VI 1.20 of the Staff Regulations. The relevant documents will therefore be posted on the notice boards of the Administration Building (N° 60) from 6 to 20 June 2003. Human Resources Division Tel. 74128

  11. Joint Advisory Appeals Board

    CERN Multimedia

    2004-01-01

    The Joint Advisory Appeals Board was convened to examine the appeal lodged by Mrs Maria DIMOU with regard to a periodic one-step increase. As the appellant has not objected, the report of the Board and the final decision of the Director-General are brought to the notice of the personnel in accordance with Article R VI 1.20 of the Staff Regulations. The relevant documents will therefore be posted on the notice boards of the Administration Building (N° 60) from 30 April to 14 May 2004. Human Resources Department Tel. 74128

  12. JOINT ADVISORY APPEALS BOARD

    CERN Multimedia

    Human Resources Division

    2001-01-01

    The Joint Advisory Appeals Board was convened to examine the appeal lodged by Mr Joël Lahaye with regard to non-resident allowance. As the appellant has not objected, the report of the Board and the final decision of the Director-General are brought to the notice of the personnel in accordance with Article R VI 1.20 of the Staff Regulations. The relevant documents will therefore be posted on the notice boards of the Administration Building (N° 60) from 18 May to 1st June 2001.

  13. Joint Advisory Appeals Board

    CERN Multimedia

    HR Department

    2008-01-01

    The Joint Advisory Appeals Board has examined the internal appeal lodged by a member of the personnel with regard to the decision not to award him a periodic one-step advancement for the 2006 reference year. The person concerned has not objected to the report of the Board and the final decision of the Director-General being brought to the notice of the members of the personnel. In application of Article R VI 1.18 of the Staff Regulations, these documents will therefore be posted on the notice board of the Main building (Bldg. 500) from 17 March to 30 March 2008. Human Resources Department Tel. 73911

  14. JOINT ADVISORY APPEALS BOARD

    CERN Multimedia

    Human Resources Division

    2002-01-01

    The Joint Advisory Appeals Board was convened to examine the appeal lodged by Mr Bertrand Nicquevert with regard to the non-resident allowance. As the appellant has not objected, the report of the Board and the final decision of the Director-General are brought to the notice of the personnel in accordance with Article R VI 1.20 of the Staff Regulations. The relevant documents will therefore be posted on the notice boards of the Administration Building (N° 60) from 29 November to 13 December 2002. Human Resources Division Tel. 74128

  15. JOINT ADVISORY APPEALS BOARD

    CERN Multimedia

    Human Resources Division

    2002-01-01

    The Joint Advisory Appeals Board was convened to examine the appeal lodged by Mr Antonio Millich with regard to advancement. As the appellant has not objected, the report of the Board and the final decision of the Director-General are brought to the notice of the personnel in accordance with Article R VI 1.20 of the Staff Regulations. The relevant documents will therefore be posted on the notice boards of the Administration Building (N° 60) from 27 September to 11 October 2002. Human Resources Division Tel. 74128

  16. Joint Advisory Appeals Board

    CERN Multimedia

    Human Resources Department

    2005-01-01

    The Joint Advisory Appeals Board was convened to examine an appeal lodged by a member of the personnel with regard to a periodic one-step increase. As the appellant has not objected, the report of the Board and the final decision of the Director-General are brought to the notice of the personnel in accordance with Article R VI 1.20 of the Staff Regulations. The relevant documents will therefore be posted on the notice boards of the Administration Building (N° 60) from 1 to 15 April 2005. Human Resources Department Tel. 74128

  17. Joint Advisory Appeals Board

    CERN Multimedia

    HR Department

    2008-01-01

    The Joint Advisory Appeals Board has examined the internal appeal lodged by a member of the personnel against the decision to grant him only a periodic one-step advancement for the 2006 reference year. The person concerned has not objected to the report of the Board and the final decision of the Director-General being brought to the attention of the members of the personnel. In application of Article R VI 1.18 of the Staff Regulations, these documents will therefore be posted on the notice board of the Main Building (Bldg. 500) from 1 September to 14 September 2008. Human Resources Department (73911)

  18. JOINT ADVISORY APPEALS BOARD

    CERN Multimedia

    Human Resources Division

    2002-01-01

    The Joint Advisory Appeals Board was convened to examine the appeal lodged by Mr Gert Jan Bossen with regard to dependent child allowance. As the appellant has not objected, the report of the Board and the final decision of the Director-General are brought to the notice of the personnel in accordance with Article R VI 1.20 of the Staff Regulations. The relevant documents will therefore be posted on the notice boards of the Administration Building (N° 60) from 1st to 15 March 2002. Human Resources Division Tel. 74128

  19. Joint Advisory Appeals Board

    CERN Multimedia

    HR Department

    2008-01-01

    The Joint Advisory Appeals Board has examined the internal appeal lodged by a member of the personnel with regard to the decision not to grant him an indefinite contract. The person concerned has not objected to the report of the Board and the final decision of the Director-General being brought to the notice of the members of the personnel. In application of Article R VI 1.18 of the Staff Regulations, these documents will therefore be posted on the notice board of the Main Building (Bldg. 500) from 26 May to 6 June 2008. Human Resources Department (73911)

  20. JOINT ADVISORY APPEALS BOARD

    CERN Multimedia

    Human Resources Division

    2002-01-01

    The Joint Advisory Appeals Board was convened to examine the appeal lodged by Mr Serge Peraire with regard to exceptional advancement. As the appellant has not objected, the report of the Board and the final decision of the Director-General are brought to the notice of the personnel in accordance with Article R VI 1.20 of the Staff Regulations. The relevant documents will therefore be posted on the notice boards of the Administration Building (N° 60) from 17 to 31 May 2002. Human Resources Division Tel. 74128

  1. Joint Advisory Appeals Board

    CERN Multimedia

    HR Department

    2008-01-01

    The Joint Advisory Appeals Board was convened to examine an internal appeal lodged by a member of the personnel with regard to the decision not to grant him an indefinite contract. The person concerned has not objected to the report of the Board and the final decision of the Director-General being brought to the notice of the members of the personnel, in accordance with Article R VI 1.18 of the Staff Regulations. These documents will therefore be posted on the notice board of the Main Building (Bldg. 60) from 21 January to 3 February 2008. Human Resources Department (73911)

  2. Patellofemoral joint motion

    International Nuclear Information System (INIS)

    Stanford, W.; Phelan, J.; Albright, J.; Kathol, M.; Rooholamini, S.A.; El-Khoury, G.Y.; Palutsis, G.R.

    1988-01-01

    This paper describes the use of ultrafast computed tomography (CT) to obtain dynamic images of the patellofemoral joint during active motion. Thirty-eight patients underwent measurements of tangent offset, bisect offset, congruence angle, patellar tilt angle, lateral patellofemoral angle, sulcus angle, and sulcus depth made during leg movement. Selected parameters were compared with Merchant views. Significant correlations were obtained between Merchant views and comparable ultrafast CT views for all parameters except sulcus angle. Correlations between the other parameters were poor. Cine strips showed two patterns of movement; the patella remained centered either throughout excursion or until the last 20 0 of full extension, when it would sublux laterally

  3. Joint Advisory Appeals Board

    CERN Multimedia

    2003-01-01

    The Joint Advisory Appeals Board was convened to examine the appeal lodged by Mr Aloïs Girardoz with regard to classification and advancement. As the appellant has not objected, the Board's report and the Director-General's decision will be brought to the notice of the personnel in accordance with Article R VI 1.20 of the Staff Regulations. The relevant documents will therefore be posted on the notice boards of the Administration Building (N° 60) from 15 to 29 August 2003. Human Resources Division Tel. 74128

  4. Glenohumeral Joint Injections

    Science.gov (United States)

    Gross, Christopher; Dhawan, Aman; Harwood, Daniel; Gochanour, Eric; Romeo, Anthony

    2013-01-01

    Context: Intra-articular injections into the glenohumeral joint are commonly performed by musculoskeletal providers, including orthopaedic surgeons, family medicine physicians, rheumatologists, and physician assistants. Despite their frequent use, there is little guidance for injectable treatments to the glenohumeral joint for conditions such as osteoarthritis, adhesive capsulitis, and rheumatoid arthritis. Evidence Acquisition: We performed a comprehensive review of the available literature on glenohumeral injections to help clarify the current evidence-based practice and identify deficits in our understanding. We searched MEDLINE (1948 to December 2011 [week 1]) and EMBASE (1980 to 2011 [week 49]) using various permutations of intra-articular injections AND (corticosteroid OR hyaluronic acid) and (adhesive capsulitis OR arthritis). Results: We identified 1 and 7 studies that investigated intra-articular corticosteroid injections for the treatment of osteoarthritis and adhesive capsulitis, respectively. Two and 3 studies investigated the use of hyaluronic acid in osteoarthritis and adhesive capsulitis, respectively. One study compared corticosteroids and hyaluronic acid injections in the treatment of osteoarthritis, and another discussed adhesive capsulitis. Conclusion: Based on existing studies and their level of evidence, there is only expert opinion to guide corticosteroid injection for osteoarthritis as well as hyaluronic acid injection for osteoarthritis and adhesive capsulitis. PMID:24427384

  5. Phytomedicine in Joint Disorders

    Directory of Open Access Journals (Sweden)

    Dorin Dragos

    2017-01-01

    Full Text Available Chronic joint inflammatory disorders such as osteoarthritis and rheumatoid arthritis have in common an upsurge of inflammation, and oxidative stress, resulting in progressive histological alterations and disabling symptoms. Currently used conventional medication (ranging from pain-killers to biological agents is potent, but frequently associated with serious, even life-threatening side effects. Used for millennia in traditional herbalism, medicinal plants are a promising alternative, with lower rate of adverse events and efficiency frequently comparable with that of conventional drugs. Nevertheless, their mechanism of action is in many cases elusive and/or uncertain. Even though many of them have been proven effective in studies done in vitro or on animal models, there is a scarcity of human clinical evidence. The purpose of this review is to summarize the available scientific information on the following joint-friendly medicinal plants, which have been tested in human studies: Arnica montana, Boswellia spp., Curcuma spp., Equisetum arvense, Harpagophytum procumbens, Salix spp., Sesamum indicum, Symphytum officinalis, Zingiber officinalis, Panax notoginseng, and Whitania somnifera.

  6. Jointly Sponsored Research Program

    Energy Technology Data Exchange (ETDEWEB)

    Everett A. Sondreal; John G. Hendrikson; Thomas A. Erickson

    2009-03-31

    U.S. Department of Energy (DOE) Cooperative Agreement DE-FC26-98FT40321 funded through the Office of Fossil Energy and administered at the National Energy Technology Laboratory (NETL) supported the performance of a Jointly Sponsored Research Program (JSRP) at the Energy & Environmental Research Center (EERC) with a minimum 50% nonfederal cost share to assist industry in commercializing and effectively applying highly efficient, nonpolluting energy systems that meet the nation's requirements for clean fuels, chemicals, and electricity in the 21st century. The EERC in partnership with its nonfederal partners jointly performed 131 JSRP projects for which the total DOE cost share was $22,716,634 (38%) and the nonfederal share was $36,776,573 (62%). Summaries of these projects are presented in this report for six program areas: (1) resource characterization and waste management, (2) air quality assessment and control, (3) advanced power systems, (4) advanced fuel forms, (5) value-added coproducts, and (6) advanced materials. The work performed under this agreement addressed DOE goals for reductions in CO{sub 2} emissions through efficiency, capture, and sequestration; near-zero emissions from highly efficient coal-fired power plants; environmental control capabilities for SO{sub 2}, NO{sub x}, fine respirable particulate (PM{sub 2.5}), and mercury; alternative transportation fuels including liquid synfuels and hydrogen; and synergistic integration of fossil and renewable resources.

  7. Joint resistance measurements of pancake and terminal joints for JT-60SA EF coils

    Energy Technology Data Exchange (ETDEWEB)

    Obana, Tetsuhiro, E-mail: obana.tetsuhiro@LHD.nifs.ac.jp [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Takahata, Kazuya; Hamaguchi, Shinji; Mito, Toshiyuki; Imagawa, Shinsaku [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Kizu, Kaname; Murakami, Haruyuki; Yoshida, Kiyoshi [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan)

    2013-11-15

    Highlights: • To evaluate the joint fabrication technology for the JT-60SA EF coils, joint resistance measurements were conducted with a joint sample. • The joint sample was composed of pancake and terminal joints. • The measurements demonstrated that both joints fulfilled the design requirement. • Considering the measurements, the characteristics of both joints were investigated using an analytical model that represents the joints. -- Abstract: To evaluate the joint fabrication technology for the JT-60SA EF coils, joint resistance measurements were conducted using a sample consisting of pancake and terminal joints. Both joints are shake-hands lap joints composed of cable-in-conduit conductors and a pure copper saddle-shaped spacer. The measurements demonstrated that both joints fulfilled the design requirement. Considering these measurements, the characteristics of both joints were investigated using analytical models that represent the joints. The analyses indicated that the characteristics of the conductors used in the joints affect the characteristics of the joints.

  8. Radiosynoviorthesis in haemaphilic joint disease

    International Nuclear Information System (INIS)

    Pad Bosch, P.J.I. van't; Putte, L.B.A. van de; Boerbooms, A.M.T.; Geerdink, P.J.

    1981-01-01

    The effects of radiosynoviorthesis on chronic haemophilic arthropathic joints were studied in six patients with severe haemophilia by a follow up study which spanned two and a half years. On clinical grounds the treatment was successful because pain and bleeding frequency diminished, although radiographic examination showed further deterioration of the treated joint. Chromosome damage was not detected. We conclude that radiosynoviorthesis is apparently changing the bleeding pattern of articular tissues without arresting the destruction and deformation of joints. (orig.) [de

  9. Stable isotopes labelled compounds

    International Nuclear Information System (INIS)

    1982-09-01

    The catalogue on stable isotopes labelled compounds offers deuterium, nitrogen-15, and multiply labelled compounds. It includes: (1) conditions of sale and delivery, (2) the application of stable isotopes, (3) technical information, (4) product specifications, and (5) the complete delivery programme

  10. Leveraging Technology for Joint Training

    National Research Council Canada - National Science Library

    Walker, Jack

    1997-01-01

    .... While this innovation will have a significant impact on education and training, it will not fulfill its potential unless joint and component commanders understand what the technologies represent...

  11. Effect of Joint Scale and Processing on the Fracture of Sn-3Ag-0.5Cu Solder Joints: Application to Micro-bumps in 3D Packages

    Science.gov (United States)

    Talebanpour, B.; Huang, Z.; Chen, Z.; Dutta, I.

    2016-01-01

    In 3-dimensional (3D) packages, a stack of dies is vertically connected to each other using through-silicon vias and very thin solder micro-bumps. The thinness of the micro-bumps results in joints with a very high volumetric proportion of intermetallic compounds (IMCs), rendering them much more brittle compared to conventional joints. Because of this, the reliability of micro-bumps, and the dependence thereof on the proportion of IMC in the joint, is of substantial concern. In this paper, the growth kinetics of IMCs in thin Sn-3Ag-0.5Cu joints attached to Cu substrates were analyzed, and empirical kinetic laws for the growth of Cu6Sn5 and Cu3Sn in thin joints were obtained. Modified compact mixed mode fracture mechanics samples, with adhesive solder joints between massive Cu substrates, having similar thickness and IMC content as actual micro-bumps, were produced. The effects of IMC proportion and strain rate on fracture toughness and mechanisms were investigated. It was found that the fracture toughness G C decreased with decreasing joint thickness ( h Joint). In addition, the fracture toughness decreased with increasing strain rate. Aging also promoted alternation of the crack path between the two joint-substrate interfaces, possibly proffering a mechanism to enhance fracture toughness.

  12. Selecting a Response in Task Switching: Testing a Model of Compound Cue Retrieval

    Science.gov (United States)

    Schneider, Darryl W.; Logan, Gordon D.

    2009-01-01

    How can a task-appropriate response be selected for an ambiguous target stimulus in task-switching situations? One answer is to use compound cue retrieval, whereby stimuli serve as joint retrieval cues to select a response from long-term memory. In the present study, the authors tested how well a model of compound cue retrieval could account for a…

  13. Temporomandibular joint movement

    International Nuclear Information System (INIS)

    Maeda, M.; Itou, S.; Ishii, Y.; Yamamoto, K.; Kawamura, Y.; Matsuda, T.; Hayashi, N.; Ishii, J.

    1992-01-01

    Ten temporomandibular joints (TMJs) of 5 healthy volunteers and 19 TMJs of internal derangements in 16 patients with splint therapy were examined with MR imaging. T1-weighted images were obtained only in the closed mouth position, and gradient recalled acquisition in steady state (GRASS) images were obtained in active opening and closing phases, allowing a pseudodynamic display of TMJ movement. All patients received protrusive splint treatment. The usefulness of MR imaging to assess the efficacy of splint therapy was evaluated. Corrected disk position with the splint in place was clearly demonstrated in 9 TMJs, corresponding with elimination of reciprocal clicking. Ten other TMJs of anterior disk displacement without reduction showed uncorrected disk position by the splint. This information could confirm the therapeutic efficacy, or suggest other treatment alternatives. GRASS MR imaging can provide accurate and physiologic information about disk function in initial and follow-up assessment of protrusive splint therapy. (orig.)

  14. JOINT ADVISORY APPEALS BOARD

    CERN Multimedia

    Human Resources Division

    2001-01-01

    The Joint Advisory Appeals Board was convened to examine the appeal lodged by Mr Neil Calder, Mrs Sudeshna Datta Cockerill, Mrs Andrée Fontbonne, Mrs Moniek Laurent and Mr Ulrich Liptow with regard to membership in the Pension Fund under the period with a Paid Associate contract, appeals dealt with on a collective basis. As the appellants have not objected, the report of the Board and the final decision of the Director-General are brought to the notice of the personnel in accordance with Article R VI 1.20 of the Staff Regulations. The relevant documents will therefore be posted on the notice boards of the Administration Building (N° 60) from 10 to 31 August 2001.

  15. Temporomandibular joint arthrography

    International Nuclear Information System (INIS)

    Choi, Hyung Sik; Lee, Kyung Soo; Kim, Myoung Joon; Jun, Young Hwan; Chang, Duk Soo; Jung, Don Young; Jung, In Won

    1988-01-01

    The stress and occlusion disturbance are very important etiologic factors in the temporomandibular joint (TMJ) pain dysfunction syndromes. Authors performed TMJ arthrograms in the patients with TMJ problem such as pain, click sound, limited motion and locking, etc. The following results noted: 1. The arthrographic findings of 22 TMJ were analyzed. a) Normal: 6 cases b) Anterior disc displacement with rediction: 6 cases · Early reduction: 2 cases · Intermediate reduction: 3 cases · Late reduction: 1 case c) Anterior disc displacement without reduction: 6 cases · Two cases had adhesion between the posterior portion of disc and the posterior surfaces of the articular eminence. 2. Among 22 cases, the clinical findings of 16 cases (73%) were compatible with arthrographic findings. 6 cases showed disparity between them.

  16. Sacroiliac joint: A review

    Directory of Open Access Journals (Sweden)

    Khushali Tilvawala

    2018-01-01

    Full Text Available Sacroiliac joint (SIJ pain is one of the common but underdiagnosed source of mechanical low back pain. The incidence is estimated to be in the range of 15%–30% in patients with nonradicular low back pain. The signs and symptoms of SIJ pain mimic pain arising from other causes of low back pain. There is no single symptom or physical examination finding that can firmly diagnose SIJ as a source of patient's pain. There is good evidence suggesting that a combination of three or more positive provocative tests strongly suggests SIJ dysfunction. Intra-articular injection with local anesthetic is considered the gold standard for diagnosis of SIJ pain. Many treatment modalities are available for SIJ pain, ranging from conservative management to surgical interventions. This review article covers all the aspects of SIJ pain, with treatment section mainly covering evidence-based interventional procedures.

  17. Compounding around the world.

    Science.gov (United States)

    Vail, Jane

    2008-01-01

    Pharmaceutical compounding is universal in its prevalence. Variations in disease patterns, culture, and tradition; the role of government in health care; and the availability of essential equipment and required agents shape a compounding profile unique to each country worldwide. In the following reflections, pharmacists form Argentina, Belgium, Colombia, Germany, Puerto Rico, Spain, and the United States describe their experiences in the compounding setting unique to their practice and their nation. The unifying theme in their comments is the dedication of each contributor to enabling recovery and ensuring the good health of his or her clients.

  18. Theoretical analysis of rolled joints

    International Nuclear Information System (INIS)

    Sinha, R.K.

    1975-01-01

    A procedure for theoretically analysing the case of an externally restrained sandwich joint formed by a hypothetical uniform hydrostatic expansion process is outlined. Reference is made to a computer program based on this theory. Results illustrating the effect of major joint variables on residual contact pressure are presented and analysed. The applicability and limitations of this theory are discussed. (author)

  19. Arthroscopy of the ankle joint

    NARCIS (Netherlands)

    van Dijk, C. N.; Scholte, D.

    1997-01-01

    Ankle arthroscopy has become a standard procedure for a variety of indications. Joint distraction is applied by many authors. A recent retrospective multicentre study provoked the following questions. Is there an indication for diagnostic arthroscopy? Can arthroscopic surgery of the ankle joint be

  20. From joint to single audits

    DEFF Research Database (Denmark)

    Holm, Claus; Thinggaard, Frank

    2018-01-01

    This study analyses audit quality differences between audits by a single big audit firm and joint audits with either one or two big audit firms. We exploit the unique situation in Denmark beginning on 1 January 2005, at which time a long-standing mandatory joint audit system for listed companies ...

  1. Transition joints in INDUS-2

    International Nuclear Information System (INIS)

    Sridhar, R.; Amalraj, William; Shukla, S.K.; Jain, A.K.

    2003-01-01

    Full text: A large number of welding joints are being employed in the fabrication of Indus-2 synchrotron storage ring being constructed at CAT. Apart from the TIG welded joints of aluminium alloy vacuum chambers, there are many other joints which are made between dissimilar metals. Stainless steel pipes are friction welded with aluminium pipes and are to be used as pumping ducts between vacuum pumps and the vacuum chambers. Similarly stainless steel flanges are fastened with aluminium flanges through a diamond seal. These joints are tested for a leak tightness of 2 x 10 -10 torr lit/sec of helium. This paper describes the details of the friction welded joints and their application in the Indus-2 synchrotron storage ring

  2. Induction brazing of complex joints

    DEFF Research Database (Denmark)

    Henningsen, Poul; Zhang, Wenqi; Bay, Niels

    2003-01-01

    , or if the hottest area is located outside the joint interface, a number of defects may appear: the braze metal may flow away from the joint, the flux may burn off, poor binding of the braze metal may appear or the braze metal may be overheated. Joint geometry as well as electro-magnetic properties of the work piece...... presents a combined numerical and experimental method for fast determination of appropriate coil geometry and position in induction brazing tube-to-plate joints of different ratios between tube and plate thickness and different combinations of the materials stainless steel, brass and copper. The method has...... proven to give successful results in brazing tube-plate joints of copper-brass, copper-stainless steel, stainless steel-brass, and stainless steel-stainless steel....

  3. Space Station alpha joint bearing

    Science.gov (United States)

    Everman, Michael R.; Jones, P. Alan; Spencer, Porter A.

    1987-01-01

    Perhaps the most critical structural system aboard the Space Station is the Solar Alpha Rotary Joint which helps align the power generation system with the sun. The joint must provide structural support and controlled rotation to the outboard transverse booms as well as power and data transfer across the joint. The Solar Alpha Rotary Joint is composed of two transition sections and an integral, large diameter bearing. Alpha joint bearing design presents a particularly interesting problem because of its large size and need for high reliability, stiffness, and on orbit maintability. The discrete roller bearing developed is a novel refinement to cam follower technology. It offers thermal compensation and ease of on-orbit maintenance that are not found in conventional rolling element bearings. How the bearing design evolved is summarized. Driving requirements are reviewed, alternative concepts assessed, and the selected design is described.

  4. Compound Semiconductor Radiation Detectors

    CERN Document Server

    Owens, Alan

    2012-01-01

    Although elemental semiconductors such as silicon and germanium are standard for energy dispersive spectroscopy in the laboratory, their use for an increasing range of applications is becoming marginalized by their physical limitations, namely the need for ancillary cooling, their modest stopping powers, and radiation intolerance. Compound semiconductors, on the other hand, encompass such a wide range of physical and electronic properties that they have become viable competitors in a number of applications. Compound Semiconductor Radiation Detectors is a consolidated source of information on all aspects of the use of compound semiconductors for radiation detection and measurement. Serious Competitors to Germanium and Silicon Radiation Detectors Wide-gap compound semiconductors offer the ability to operate in a range of hostile thermal and radiation environments while still maintaining sub-keV spectral resolution at X-ray wavelengths. Narrow-gap materials offer the potential of exceeding the spectral resolutio...

  5. Hexavalent Chromium Compounds

    Science.gov (United States)

    Learn about chromium, exposure to which can increase your risk of lung cancer and cancer of the paranasal sinuses and nasal cavity. Hexavalent chromium compounds have been used as corrosion inhibitors in a wide variety of products and processes.

  6. MEA 86 Compound data

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data file contains the full raw parameter data for the 86 compounds tested in the developmental MEA assay, as well as Area Under the Curve (AUC) calculations...

  7. Unlock your Compound Management

    OpenAIRE

    Steffen Eller

    2016-01-01

    Pharmaceutical industry faces the increased demand for innovative medicines against various diseases. In this regard, the compound library in pharmaceutical industry is the most valuable asset. However, the compound distribution from the library into the screening plates is often still done manually and binds highly qualified resources to very time-consuming, tedious and error-prone tasks. To overcome these challenges, Chemspeed launched the first automated true one-to-one gravimetric "pi...

  8. Phenolic Molding Compounds

    Science.gov (United States)

    Koizumi, Koji; Charles, Ted; de Keyser, Hendrik

    Phenolic Molding Compounds continue to exhibit well balanced properties such as heat resistance, chemical resistance, dimensional stability, and creep resistance. They are widely applied in electrical, appliance, small engine, commutator, and automotive applications. As the focus of the automotive industry is weight reduction for greater fuel efficiency, phenolic molding compounds become appealing alternatives to metals. Current market volumes and trends, formulation components and its impact on properties, and a review of common manufacturing methods are presented. Molding processes as well as unique advanced techniques such as high temperature molding, live sprue, and injection/compression technique provide additional benefits in improving the performance characterisitics of phenolic molding compounds. Of special interest are descriptions of some of the latest innovations in automotive components, such as the phenolic intake manifold and valve block for dual clutch transmissions. The chapter also characterizes the most recent developments in new materials, including long glass phenolic molding compounds and carbon fiber reinforced phenolic molding compounds exhibiting a 10-20-fold increase in Charpy impact strength when compared to short fiber filled materials. The role of fatigue testing and fatigue fracture behavior presents some insight into long-term reliability and durability of glass-filled phenolic molding compounds. A section on new technology outlines the important factors to consider in modeling phenolic parts by finite element analysis and flow simulation.

  9. Towards Scalable Strain Gauge-Based Joint Torque Sensors

    Science.gov (United States)

    D’Imperio, Mariapaola; Cannella, Ferdinando; Caldwell, Darwin G.; Cuschieri, Alfred

    2017-01-01

    During recent decades, strain gauge-based joint torque sensors have been commonly used to provide high-fidelity torque measurements in robotics. Although measurement of joint torque/force is often required in engineering research and development, the gluing and wiring of strain gauges used as torque sensors pose difficulties during integration within the restricted space available in small joints. The problem is compounded by the need for a scalable geometric design to measure joint torque. In this communication, we describe a novel design of a strain gauge-based mono-axial torque sensor referred to as square-cut torque sensor (SCTS), the significant features of which are high degree of linearity, symmetry, and high scalability in terms of both size and measuring range. Most importantly, SCTS provides easy access for gluing and wiring of the strain gauges on sensor surface despite the limited available space. We demonstrated that the SCTS was better in terms of symmetry (clockwise and counterclockwise rotation) and more linear. These capabilities have been shown through finite element modeling (ANSYS) confirmed by observed data obtained by load testing experiments. The high performance of SCTS was confirmed by studies involving changes in size, material and/or wings width and thickness. Finally, we demonstrated that the SCTS can be successfully implementation inside the hip joints of miniaturized hydraulically actuated quadruped robot-MiniHyQ. This communication is based on work presented at the 18th International Conference on Climbing and Walking Robots (CLAWAR). PMID:28820446

  10. Joint action aesthetics.

    Science.gov (United States)

    Vicary, Staci; Sperling, Matthias; von Zimmermann, Jorina; Richardson, Daniel C; Orgs, Guido

    2017-01-01

    Synchronized movement is a ubiquitous feature of dance and music performance. Much research into the evolutionary origins of these cultural practices has focused on why humans perform rather than watch or listen to dance and music. In this study, we show that movement synchrony among a group of performers predicts the aesthetic appreciation of live dance performances. We developed a choreography that continuously manipulated group synchronization using a defined movement vocabulary based on arm swinging, walking and running. The choreography was performed live to four audiences, as we continuously tracked the performers' movements, and the spectators' affective responses. We computed dynamic synchrony among performers using cross recurrence analysis of data from wrist accelerometers, and implicit measures of arousal from spectators' heart rates. Additionally, a subset of spectators provided continuous ratings of enjoyment and perceived synchrony using tablet computers. Granger causality analyses demonstrate predictive relationships between synchrony, enjoyment ratings and spectator arousal, if audiences form a collectively consistent positive or negative aesthetic evaluation. Controlling for the influence of overall movement acceleration and visual change, we show that dance communicates group coordination via coupled movement dynamics among a group of performers. Our findings are in line with an evolutionary function of dance-and perhaps all performing arts-in transmitting social signals between groups of people. Human movement is the common denominator of dance, music and theatre. Acknowledging the time-sensitive and immediate nature of the performer-spectator relationship, our study makes a significant step towards an aesthetics of joint actions in the performing arts.

  11. Joint seal in tank

    International Nuclear Information System (INIS)

    Colquhoun, J.; White, G.V.

    1981-01-01

    A seal for a joint or gap between edges of adjacent wall sections (e.g. of concrete) of a liquid-containing vessel, such as a nuclear reactor cooling pond, comprises a sheet metal strip having longitudinally-extending edge parts, secured to the respective vessel-section edges, and a central part which is longitudinally corrugated to provide sufficient flexibility to accommodate slight relative movements between the vessel-section edges (e.g. due to thermal expansions). The edges of the sheet metal of the strip are turned in so that the edge parts of the strip are formed as generally U-section channels. These accommodate longitudinally extending securing bars which are bolted to the vessel wall sections by bolts which pass through the bars, through the free-edged wall of the channel section and through a longitudinally extending resilient seal pad compressed between that wall of the channel section and the vessel wall section to which it is secured. The other wall of the channel section (integral with the corrugated central part of the strip) has access windows through which the bolts are inserted and tightened, the windows being then closed off in liquid-tight manner by welding closure caps over them. (author)

  12. Temporomandibular Joint Regenerative Medicine

    Directory of Open Access Journals (Sweden)

    Xavier Van Bellinghen

    2018-02-01

    Full Text Available The temporomandibular joint (TMJ is an articulation formed between the temporal bone and the mandibular condyle which is commonly affected. These affections are often so painful during fundamental oral activities that patients have lower quality of life. Limitations of therapeutics for severe TMJ diseases have led to increased interest in regenerative strategies combining stem cells, implantable scaffolds and well-targeting bioactive molecules. To succeed in functional and structural regeneration of TMJ is very challenging. Innovative strategies and biomaterials are absolutely crucial because TMJ can be considered as one of the most difficult tissues to regenerate due to its limited healing capacity, its unique histological and structural properties and the necessity for long-term prevention of its ossified or fibrous adhesions. The ideal approach for TMJ regeneration is a unique scaffold functionalized with an osteochondral molecular gradient containing a single stem cell population able to undergo osteogenic and chondrogenic differentiation such as BMSCs, ADSCs or DPSCs. The key for this complex regeneration is the functionalization with active molecules such as IGF-1, TGF-β1 or bFGF. This regeneration can be optimized by nano/micro-assisted functionalization and by spatiotemporal drug delivery systems orchestrating the 3D formation of TMJ tissues.

  13. Interfacial reaction of Sn-based solder joint in the package system

    Science.gov (United States)

    Gu, Huandi

    In this thesis, I report a study on the effect of the solder size on intermetallic layer formation by comparing the morphology change and growth rate of two different size solder joint aged at a same temperature for different aging time. The layer thickness and microstructure were analyzed using scanning electron microscopy (SEM). Photoshop was used to measure the thickness of intermetallic compound. Two different size of solder joints with composition of Sn-Ag-Cu (305) were used.

  14. The joint in psoriatic arthritis.

    Science.gov (United States)

    Mortezavi, Mahta; Thiele, Ralph; Ritchlin, Christopher

    2015-01-01

    Psoriatic arthritis (PsA), a chronic inflammatory joint disease associated with psoriasis, is notable for diversity in disease presentation, course and response to treatment. Equally varied are the types of musculoskeletal involvement which include peripheral and axial joint disease, dactylitis and enthesitis. In this review, we focus on the psoriatic joint and discuss pathways that underlie synovial, cartilage and bone inflammation and highlight key histopathologic features. The pivotal inflammatory mechanisms and pathobiology of PsA parallel findings in other forms of spondyloarthritis but are distinct from disease pathways described in rheumatoid synovitis and bone disease. The diagnosis of PsA from both a clinical and imaging perspective is also discussed.

  15. Joint action aesthetics.

    Directory of Open Access Journals (Sweden)

    Staci Vicary

    Full Text Available Synchronized movement is a ubiquitous feature of dance and music performance. Much research into the evolutionary origins of these cultural practices has focused on why humans perform rather than watch or listen to dance and music. In this study, we show that movement synchrony among a group of performers predicts the aesthetic appreciation of live dance performances. We developed a choreography that continuously manipulated group synchronization using a defined movement vocabulary based on arm swinging, walking and running. The choreography was performed live to four audiences, as we continuously tracked the performers' movements, and the spectators' affective responses. We computed dynamic synchrony among performers using cross recurrence analysis of data from wrist accelerometers, and implicit measures of arousal from spectators' heart rates. Additionally, a subset of spectators provided continuous ratings of enjoyment and perceived synchrony using tablet computers. Granger causality analyses demonstrate predictive relationships between synchrony, enjoyment ratings and spectator arousal, if audiences form a collectively consistent positive or negative aesthetic evaluation. Controlling for the influence of overall movement acceleration and visual change, we show that dance communicates group coordination via coupled movement dynamics among a group of performers. Our findings are in line with an evolutionary function of dance-and perhaps all performing arts-in transmitting social signals between groups of people. Human movement is the common denominator of dance, music and theatre. Acknowledging the time-sensitive and immediate nature of the performer-spectator relationship, our study makes a significant step towards an aesthetics of joint actions in the performing arts.

  16. Joint action aesthetics

    Science.gov (United States)

    Vicary, Staci; Sperling, Matthias; von Zimmermann, Jorina; Richardson, Daniel C.

    2017-01-01

    Synchronized movement is a ubiquitous feature of dance and music performance. Much research into the evolutionary origins of these cultural practices has focused on why humans perform rather than watch or listen to dance and music. In this study, we show that movement synchrony among a group of performers predicts the aesthetic appreciation of live dance performances. We developed a choreography that continuously manipulated group synchronization using a defined movement vocabulary based on arm swinging, walking and running. The choreography was performed live to four audiences, as we continuously tracked the performers’ movements, and the spectators’ affective responses. We computed dynamic synchrony among performers using cross recurrence analysis of data from wrist accelerometers, and implicit measures of arousal from spectators’ heart rates. Additionally, a subset of spectators provided continuous ratings of enjoyment and perceived synchrony using tablet computers. Granger causality analyses demonstrate predictive relationships between synchrony, enjoyment ratings and spectator arousal, if audiences form a collectively consistent positive or negative aesthetic evaluation. Controlling for the influence of overall movement acceleration and visual change, we show that dance communicates group coordination via coupled movement dynamics among a group of performers. Our findings are in line with an evolutionary function of dance–and perhaps all performing arts–in transmitting social signals between groups of people. Human movement is the common denominator of dance, music and theatre. Acknowledging the time-sensitive and immediate nature of the performer-spectator relationship, our study makes a significant step towards an aesthetics of joint actions in the performing arts. PMID:28742849

  17. Fluorine-18 labelled compounds

    International Nuclear Information System (INIS)

    Kleijn, J.P. de

    1978-01-01

    The work presented in this thesis deals with the problems involved in the adaption of reactor-produced fluorine-18 to the synthesis of 18 F-labelled organic fluorine compounds. Several 18 F-labelling reagents were prepared and successfully applied. The limitations to the synthetic possibilities of reactor-produced fluoride- 18 become manifest in the last part of the thesis. An application to the synthesis of labelled aliphatic fluoro amino acids has appeared to be unsuccessful as yet, although some other synthetic approaches can be indicated. Seven journal articles (for which see the availability note) are used to compose the four chapters and three appendices. The connecting text gives a survey of known 18 F-compounds and methods for preparing such compounds. (Auth.)

  18. Aging treatment characteristics of solder bump joint for high reliability optical module

    International Nuclear Information System (INIS)

    Kim, Kyung-Seob; Yu, Chung-Hee; Yang, Jun-Mo

    2004-01-01

    The joint strength and fracture surfaces of Sn-37 mass% Pb and Au stud bumps for photo diode packages after isothermal aging testing were studied experimentally. Al/Au stud bumps and Cu/Sn-37 mass% Pb solders were adopted, and aged for up to 900 h to analyze the effect of intermetallic compound (IMC). The joint strength decreased with aging time. The diffraction patterns of Cu 6 Sn 5 , scallop-shaped IMCs, and planar-shaped Cu 3 Sn were characterized using transmission electron microscopy (TEM). The formation of Kirkendall voids and the growth of IMCs at the solder were found to be a possible mechanism for joint strength reduction

  19. Education: A Joint Transformation Enabler

    National Research Council Canada - National Science Library

    Alexander, Renita

    2003-01-01

    ... in an organization not known for its adaptability. Underlying the pursuit of transformational concepts necessary to respond to 21st century challenges is an emphasis on joint operations and doctrine...

  20. Finishing touch to joint venture

    CERN Multimedia

    2003-01-01

    "A new process for polishing titanium and its alloys has been announced following an agreement between Bripol (an Anopol/Delmet joint venture) of Birmingham and the European Organisation for Nuclear Reseach (CERN) in Geneva" (1 paragraph).

  1. MRI of the hip joint

    International Nuclear Information System (INIS)

    Czerny, C.; Noebauer-Huhmann, I.M.; Imhof, H.

    2005-01-01

    Magnetic resonance imaging (MRI) is performed to diagnose many pathologic conditions affecting the hip joint. Either conventional MRI (without contrast enhancement of the joint cavity) or MR arthrography is used to detect and most accurately differentiate hip joint pathologies. Conventional MRI is performed in cases of bone marrow edema, necrosis, arthrosis and especially the so-called ''activated arthrosis'', as well as in inflammatory and tumorous entities. MR arthography, which has only recently become available for use, is excellently suited for diagnosing lesions of the acetabular labrum, cartilage lesions, and free articular bodies. This article provides an overview about MRI characteristics and their accuracy of hip joint diseases and the impact on the therapeutic procedure. (orig.)

  2. Campus/Industry Joint Ventures.

    Science.gov (United States)

    McDonald, Eugene J.

    1985-01-01

    Opportunities for joint economic ventures of colleges and industry are discussed, and a variety of ventures undertaken by Duke University are outlined, including a health club, hotel, and office building. Tax and financing considerations are noted. (MSE)

  3. Engine mounts and structural joints

    Indian Academy of Sciences (India)

    mental studies are presented, and limitations of the passive device are briefly discussed. .... For the sake of simplifying formulations, several studies have used .... that the component mode synthesis methods work well when the joint stiffness is ...

  4. Practical aspects of joint implementation

    International Nuclear Information System (INIS)

    Michaelowa, A.

    1995-01-01

    Article 4, 2a of the UN Framework Convention on Climate Change states the possibility of joint policies of different countries to achieve national greenhouse gas reduction commitments (Joint Implementation). The cost of reducing greenhouse gas emissions can be reduced drastically if industrialized countries shift abatement activities to developing countries as marginal cost of reduction is much higher in the former countries. In this way economic efficiency of abatement measures can be raised to the point where marginal cost is equal all over the world. At the Conference of the Parties in Berlin in March 1995, criteria for Joint Implementation are to be established. The paper discusses possible forms of Joint Implementation and develops criteria

  5. Joint Logistics, Fact or Fiction?

    National Research Council Canada - National Science Library

    Carroll, Walton

    1998-01-01

    ...) and the evolution of Joint doctrine to meet these new demands. The focus of this examination remains at the strategic level and the ability of the Services to meet the logistical demands of the modern theater battlefield...

  6. Joint Performance and Planning System

    Data.gov (United States)

    US Agency for International Development — A joint State/USAID system hosted by State that integrates resource and performance information at the program level and enables more flexible and frequent entry of...

  7. Torsion testing of bed joints

    DEFF Research Database (Denmark)

    Hansen, Klavs Feilberg; Pedersen, Carsten Mørk

    2008-01-01

    This paper describes a simple test method for determining the torsion strength of a single bed joint between two bricks and presents results from testing using this test method. The setup for the torsion test is well defined, require minimal preparation of the test specimen and the test can...... be carried out directly in a normal testing machine. The torsion strength is believed to be the most important parameter in out-of-plane resistance of masonry walls subjected to bending about an axis perpendicular to the bed joints. The paper also contains a few test results from bending of small walls about...... an axis perpendicular to the bed joints, which indicate the close connection between these results and results from torsion tests. These characteristics make the torsion strength well suited to act as substitute parameter for the bending strength of masonry about an axis perpendicular to the bed joints....

  8. Chloric organic compound

    International Nuclear Information System (INIS)

    Moalem, F.

    2000-01-01

    Since many years ago, hazardous and toxic refuses which are results of human activities has been carelessly without any Biological and Engineering facts and knowledge discharged into our land and water. The effects of discharging those materials in environment are different. Some of refuse materials shows short and other has long-time adverse effects in our environment, Among hazardous organic chemical materials, chlorine, consider, to be the main element. Organic materials with chlorine is called chlorine hydrocarbon as a hazardous compound. This paper discuss the hazardous materials especially chloric organic compound and their misuse effects in environment and human being

  9. Medicinal gold compounds

    International Nuclear Information System (INIS)

    Parish, R.V.; Cottrill, S.M.

    1987-01-01

    A major use of gold compounds in the pharmaceutical industry is for anti-arthritic agents. The disease itself is not understood and little is known about the way in which the drugs act, but detailed pictures of the distribution of gold in the body are available, and some of the relevant biochemistry is beginning to emerge. The purpose of this article is to give a survey of the types of compounds presently employed in medicine, of the distribution of gold in the body which results from their use, and of some relevant chemistry. Emphasis is placed on results obtained in the last few years

  10. Compound semiconductor device physics

    CERN Document Server

    Tiwari, Sandip

    2013-01-01

    This book provides one of the most rigorous treatments of compound semiconductor device physics yet published. A complete understanding of modern devices requires a working knowledge of low-dimensional physics, the use of statistical methods, and the use of one-, two-, and three-dimensional analytical and numerical analysis techniques. With its systematic and detailed**discussion of these topics, this book is ideal for both the researcher and the student. Although the emphasis of this text is on compound semiconductor devices, many of the principles discussed will also be useful to those inter

  11. Prediction of intermetallic compounds

    International Nuclear Information System (INIS)

    Burkhanov, Gennady S; Kiselyova, N N

    2009-01-01

    The problems of predicting not yet synthesized intermetallic compounds are discussed. It is noted that the use of classical physicochemical analysis in the study of multicomponent metallic systems is faced with the complexity of presenting multidimensional phase diagrams. One way of predicting new intermetallics with specified properties is the use of modern processing technology with application of teaching of image recognition by the computer. The algorithms used most often in these methods are briefly considered and the efficiency of their use for predicting new compounds is demonstrated.

  12. Microstructural Characteristics and Mechanical Properties of an Electron Beam-Welded Ti/Cu/Ni Joint

    Science.gov (United States)

    Zhang, Feng; Wang, Ting; Jiang, Siyuan; Zhang, Binggang; Feng, Jicai

    2018-05-01

    Electron beam welding experiments of TA15 titanium alloy to GH600 nickel superalloy with and without a copper sheet interlayer were carried out. Surface appearance, microstructure and phase constitution of the joint were examined by optical microscopy, scanning electron microscopy and x-ray diffraction analysis. Mechanical properties of Ti/Ni and Ti/Cu/Ni joint were evaluated based on tensile strength and microhardness tests. The results showed that cracking occurred in Ti/Ni electron beam weldment for the formation of brittle Ni-Ti intermetallics, while a crack-free electron beam-welded Ti/Ni joint can be obtained by using a copper sheet as filler metal. The addition of copper into the weld affected the welding metallurgical process of the electron beam-welded Ti/Ni joint significantly and was helpful for restraining the formation of Ti-Ni intermetallics in Ti/Ni joint. The microstructure of the weld was mainly characterized by a copper-based solid solution and Ti-Cu interfacial intermetallic compounds. Ti-Ni intermetallic compounds were almost entirely suppressed. The hardness of the weld zone was significantly lower than that of Ti/Ni joint, and the tensile strength of the joint can be up to 282 MPa.

  13. Management of Prosthetic Joint Infection.

    Science.gov (United States)

    Tande, Aaron J; Gomez-Urena, Eric O; Berbari, Elie F; Osmon, Douglas R

    2017-06-01

    Although uncommon, prosthetic joint infection is a devastating complication. This challenging condition requires a coordinated management approach to achieve good patient outcomes. This review details the general principles to consider when managing patients with prosthetic joint infection. The different medical/surgical treatment strategies and how to appropriately select a strategy are discussed. The data to support each strategy are presented, along with discussion of antimicrobial strategies in specific situations. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Joint probabilities and quantum cognition

    International Nuclear Information System (INIS)

    Acacio de Barros, J.

    2012-01-01

    In this paper we discuss the existence of joint probability distributions for quantumlike response computations in the brain. We do so by focusing on a contextual neural-oscillator model shown to reproduce the main features of behavioral stimulus-response theory. We then exhibit a simple example of contextual random variables not having a joint probability distribution, and describe how such variables can be obtained from neural oscillators, but not from a quantum observable algebra.

  15. Joint probabilities and quantum cognition

    Energy Technology Data Exchange (ETDEWEB)

    Acacio de Barros, J. [Liberal Studies, 1600 Holloway Ave., San Francisco State University, San Francisco, CA 94132 (United States)

    2012-12-18

    In this paper we discuss the existence of joint probability distributions for quantumlike response computations in the brain. We do so by focusing on a contextual neural-oscillator model shown to reproduce the main features of behavioral stimulus-response theory. We then exhibit a simple example of contextual random variables not having a joint probability distribution, and describe how such variables can be obtained from neural oscillators, but not from a quantum observable algebra.

  16. Continuum description for jointed media

    International Nuclear Information System (INIS)

    Thomas, R.K.

    1982-04-01

    A general three-dimensional continuum description is presented for a material containing regularly spaced and approximately parallel jointing planes within a representative elementary volume. Constitutive relationships are introduced for linear behavior of the base material and nonlinear normal and shear behavior across jointing planes. Furthermore, a fracture permeability tensor is calculated so that deformation induced alterations to the in-situ values can be measured. Examples for several strain-controlled loading paths are presented

  17. Value of knee joint arthrography

    International Nuclear Information System (INIS)

    Luzsa, Gyoergy; Kiss Toth, Peter

    1985-01-01

    On the basis of the literature and the analysis of 204 examinations, the method and clinical application of knee joint arthrography are reviewed. 50 out of the 54 operated cases were perfectly diagnosed. The double contrast knee joint arthrography can be applied to detect meniscus changes, popliteal cysts, synovial disorders and chondral defects. The effectiveness of arthrography and arthroscopy was compared and the introduction of the former in each county seat is suggested. (author)

  18. The study on joining carbon/carbon composites using Ti–Ni–Si compound

    International Nuclear Information System (INIS)

    Wang Jie; Li Kezhi; Song Xinrui; Guo Lingjun; Li Wei; Li Zhaoqian

    2012-01-01

    Highlights: ► First study to join C/C composites using Ti–Ni–Si compound. ► The average joint shear strength can reach up to 23.58 MPa. ► Strong joints are apt to fracture through interlayer, interfaces and C/C matrix. ► Phase compositions in joints are varied with increasing joining temperature. - Abstract: 2D carbon/carbon (C/C) composites have been successfully joined by partial transient liquid phase (PTLP) bonding using Ti–Ni–Si compound as interlayer. The shear strengths of C/C joints were found to be affected observably by joining temperature, joining pressure and holding time. The optimum process parameters were determined at 1150 °C, 30 MPa, 45 min, and the maximum joint shear strength was obtained under this optimum process condition with an average value of 23.58 MPa. Microstructures and compositions of joints were analyzed by scanning electronic microscopy (SEM), energy disperse spectroscopy (EDS) and X-ray diffraction (XRD). Results showed that element interdiffusions and chemical reactions took place in the joining zone and various compounds including Ni 4 Si 7 Ti 4 , TiSi 2 , SiC and TiC were produced, by which compact interlayer and strong interface were formed in C/C joints. The shear morphology indicated there were three fracture modes in C/C joints and the fracture was apt to occur through interlayer, interface and C/C matrix in strong joints. Thermal shock resistance experimental results revealed that joint shear strength has a rapid drop after 5 thermal cycles and then reduces gradually with the increase of thermal cycles between room temperature and 1000 °C.

  19. Compound floating pivot micromechanisms

    Science.gov (United States)

    Garcia, Ernest J.

    2001-04-24

    A new class of tilting micromechanical mechanisms have been developed. These new mechanisms use compound floating pivot structures to attain far greater tilt angles than are practical using other micromechanical techniques. The new mechanisms are also capable of bi-directional tilt about multiple axes.

  20. The Onium Compounds

    Science.gov (United States)

    Tsarevsky, Nicolay V.; Slaveykova, Vera; Manev, Stefan; Lazarov, Dobri

    1997-06-01

    The onium salts are of a big interest for theoretical and structural chemistry, and for organic synthesis. Some representatives of the group (e.g. ammonium salts) were known from the oldest times. Many onium salts are met the nature: ammonium salts (either as inorganic salts, and organic derivatives, e.g. aminoacids, salts of biogenic amines and alkaloids, etc.); oxonium salts (plant pigments as anthocyans are organic oxonium compounds), etc. In 1894 C. Hartmann and V. Meyer prepared the first iodonium salts - 4-iododiphenyliodonium hydrogensulfate and diphenyliodonium salts, and suggested the ending -onium for all compounds with properties similar to those of ammonium salts. Nowadays onium compounds of almost all nonmetals are synthesised and studied. A great variety of physical methods: diffraction (e.g. XRD) and spectral methods (IR-, NMR-, and UV-spectra), as well as the chemical properties and methods of preparation of onium salts have been used in determination of the structure of these compounds. The application of different onium salts is immense. Ammonium, phosphonium and sulfonium salts are used as phase-transfer catalysts; diazonium salts - for the preparation of dyes, metalochromic and pH-indicators. All the onium salts and especially diazonium and iodonium salts are very useful reagents in organic synthesis.

  1. Forecasting of superconducting compounds

    International Nuclear Information System (INIS)

    Savitskii, E.M.; Gribulya, V.G.; Kiseleva, N.N.

    1981-01-01

    In forecasting new superconducting intermetallic compounds of the A15 and Mo 3 Se types most promising from the viewpoint of high critical temperature Tsub(c), high critical magnetic fields Hsub(c), and high critical currents and in estimating their transition temperature it is proposed to apply cybernetic methods of computer learning

  2. NATURAL POLYACETYLENE COMPOUNDS

    Directory of Open Access Journals (Sweden)

    A. M. Nasukhova

    2014-01-01

    Full Text Available In article the review of the initial stage of researches of natural polyacetylene compounds is resulted. The high reactionary ability leading to fast oxidation and degradation of these compounds, especially at influence of Uf-light, oxygen of air, pH and other factors, has caused the serious difficulties connected with an establishment of structure and studying of their physical and chemical properties. Therefore the greatest quantity of works of this stage is connected with studying of essential oils of plants from families Apiaceae, Araliaceae, Asteraceae, Campanulaceae, Olacaceae, Pittosporaceae and Santalaceae where have been found out, basically, diacetylene compounds. About development of physical and chemical methods of the analysis of possibility of similar researches have considerably extended. More than 2000 polyacetylenes are known today, from them more than 1100 are found out in plants fam. Asteraceae. Revolution in the field of molecular biology has allowed to study processes of biosynthesis of these compounds intensively.

  3. Aminopropyl thiophene compounds

    International Nuclear Information System (INIS)

    Goodman, M.M.; Knapp, F.F.

    1990-01-01

    This patent describes radiopharmaceuticals useful in brain imaging comprising radiohalogenated thienylethylamine derivatives. The compounds are 5-halo-thiophene-2-isopropyl amines able to cross the blood-brain barrier and be retained for a sufficient length of time to allow the evaluation of regional blood flow by radioimaging of the brain

  4. Aminopropyl thiophene compounds

    Science.gov (United States)

    Goodman, Mark M.; Knapp, Jr., Furn F.

    1990-01-01

    Radiopharmaceuticals useful in brain imaging comprising radiohalogenated thienylethylamine derivatives. The compounds are 5-halo-thiophene-2-isopropyl amines able to cross the blood-brain barrier and be retained for a sufficient length of time to allow the evaluation of regional blood flow by radioimaging of the brain.

  5. Hyperon compound nucleus

    International Nuclear Information System (INIS)

    Yamazaki, Toshimitsu.

    1987-11-01

    The formation of various hypernuclei from K - absorption at rest is discussed from the viewpoints of compound decay of highly excited hypernuclei in contrast to the direct reaction mechanism. Recent (stopped K - , π) experiments at KEK as well as old data of emulsion and bubble chamber experiments are discussed. Some future direction of hypernuclear spectroscopy is suggested. (author)

  6. Toxicology of perfluorinated compounds

    Energy Technology Data Exchange (ETDEWEB)

    Stahl, Thorsten [Hessian State Laboratory, Wiesbaden (Germany); Mattern, Daniela; Brunn, Hubertus [Hessian State Laboratory, Giessen (Germany)

    2011-12-15

    Perfluorinated compounds [PFCs] have found a wide use in industrial products and processes and in a vast array of consumer products. PFCs are molecules made up of carbon chains to which fluorine atoms are bound. Due to the strength of the carbon/fluorine bond, the molecules are chemically very stable and are highly resistant to biological degradation; therefore, they belong to a class of compounds that tend to persist in the environment. These compounds can bioaccumulate and also undergo biomagnification. Within the class of PFC chemicals, perfluorooctanoic acid and perfluorosulphonic acid are generally considered reference substances. Meanwhile, PFCs can be detected almost ubiquitously, e.g., in water, plants, different kinds of foodstuffs, in animals such as fish, birds, in mammals, as well as in human breast milk and blood. PFCs are proposed as a new class of 'persistent organic pollutants'. Numerous publications allude to the negative effects of PFCs on human health. The following review describes both external and internal exposures to PFCs, the toxicokinetics (uptake, distribution, metabolism, excretion), and the toxicodynamics (acute toxicity, subacute and subchronic toxicities, chronic toxicity including carcinogenesis, genotoxicity and epigenetic effects, reproductive and developmental toxicities, neurotoxicity, effects on the endocrine system, immunotoxicity and potential modes of action, combinational effects, and epidemiological studies on perfluorinated compounds). (orig.)

  7. Chemical compounds in teak

    Directory of Open Access Journals (Sweden)

    Fernanda Viana da Silva Leonardo

    2015-09-01

    Full Text Available Quinone compounds are largely generated at extractive fraction of the woods in a complex and variable biological system. The literature has indications for many segments from food industry to pharmaceutical industry. Within the field of industrial use of wood, they are less desirable since they are treated only as incidental substances in production strings of pulp, paper, charcoal, and sawmill. In spite of its small amount, compared to other chemical compounds called essential, these substances have received special attention from researchers revealing a diverse range of offerings to market products textiles, pharmaceuticals, colorants, and other polymers, for which are being tested and employed. Quinones are found in fungi, lichens, and mostly in higher plants. Tectona grandis, usually called teak, is able to biosynthesize anthraquinones, which is a quinone compound, byproduct of secondary metabolism. This species provides wood that is much prized in the furniture sector and can also be exploited for metabolites to supply the market in quinone compounds and commercial development of new technologies, adding value to the plantations of this species within our country.

  8. Selenium-75-labelled foliate compounds

    International Nuclear Information System (INIS)

    1974-01-01

    A saturation method to analyze a foliate is presented; it uses competitive reaction of the compound to be measured and of a radioactive-labelled version of this compound with a reagent specific to this compound present in insufficient quantity to combine with the whole of the compound and its labelled version, separation of the bound compound from its non-bound homologue and measurement of the radioactivity concentration in the bound compound, the non-bound compound or both. The radioactive isotope used in the labelled foliate is selenium 75 [fr

  9. Branching miter joints : principles and artwork

    NARCIS (Netherlands)

    Verhoeff, T.; Verhoeff, K.; Hart, G.W.; Sarhangi, R.

    2010-01-01

    A miter joint connects two beams, typically of the same cross section, at an angle such that the longitudinal beam edges continue across the joint. When more than two beams meet in one point, like in a tree, we call this a branching joint. In a branching miter joint, the beams’ longitudinal edges

  10. 12 CFR 347.107 - Joint ventures.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Joint ventures. 347.107 Section 347.107 Banks... INTERNATIONAL BANKING § 347.107 Joint ventures. (a) Joint ventures. If a bank, directly or indirectly, acquires or holds an equity interest in a foreign organization that is a joint venture, and the bank or its...

  11. About the Joint Chiefs of Staff

    Science.gov (United States)

    Skip to main content (Press Enter). Toggle navigation Joint Chiefs of Staff Joint Chiefs of Staff Joint Chiefs of Staff Facebook Twitter YouTube Flickr Blog Instagram Search JCS: Search Search Search JCS: Search Home Media News Photos Videos Publications About The Joint Staff Chairman Vice Chairman

  12. Degenerative Joint Diseases and Neuroinflammation.

    Science.gov (United States)

    Fusco, Mariella; Skaper, Stephen D; Coaccioli, Stefano; Varrassi, Giustino; Paladini, Antonella

    2017-04-01

    Rheumatic and joint diseases, as exemplified by osteoarthritis and rheumatoid arthritis, are among the most widespread painful and disabling pathologies across the globe. Given the continuing rise in life expectancy, their prevalence is destined to grow. Osteoarthritis, a degenerative joint disease, is, in particular, on its way to becoming the fourth leading cause of disability worldwide by 2020, with the rising incidence of obesity in addition to age being important factors. It is estimated that 25% of osteoarthritic individuals are unable to perform daily activities. Accompanying osteoarthritis is rheumatoid arthritis, which is a chronic systemic disease that often causes pain and deformity. At least 50% of those affected are unable to remain gainfully employed within 10 years of disease onset. A growing body of evidence now points to inflammation, locally and more systemically, as a promoter of damage to joints and bones, as well as joint-related functional deficits. The pathogenesis underlying joint diseases remains unclear; however, it is currently believed that cross-talk between cartilage and subchondral bone-and loss of balance between these two structures in joint diseases-is a critical element. This view is amplified by the presence of mast cells, whose dysregulation is associated with alterations of junction structures (cartilage, bone, synovia, matrix, nerve endings, and blood vessels). In addition, persistent activation of mast cells facilitates the development of spinal neuroinflammation mediated through their interaction with microglia. Unfortunately, current treatment strategies for rheumatic and articular disease are symptomatic and do little to limit disease progression. Research now should be directed at therapeutic modalities that target osteoarticular structural elements and thereby delaying disease progression and joint replacement. © 2016 World Institute of Pain.

  13. Management of acromioclavicular joint injuries.

    Science.gov (United States)

    Li, Xinning; Ma, Richard; Bedi, Asheesh; Dines, David M; Altchek, David W; Dines, Joshua S

    2014-01-01

    Acromioclavicular joint injuries are among the most common shoulder girdle injuries in athletes and most commonly result from a direct force to the acromion with the arm in an adducted position. Acromioclavicular joint injuries often present with associated injuries to the glenohumeral joint, including an increased incidence of superior labrum anterior posterior (SLAP) tears that may warrant further evaluation and treatment. Anteroposterior stability of the acromioclavicular joint is conferred by the capsule and acromioclavicular ligaments, of which the posterior and superior ligaments are the strongest. Superior-inferior stability is maintained by the coracoclavicular (conoid and trapezoid) ligaments. Type-I or type-II acromioclavicular joint injuries have been treated with sling immobilization, early shoulder motion, and physical therapy, with favorable outcomes. Return to activity can occur when normal shoulder motion and strength are obtained and the shoulder is asymptomatic as compared with the contralateral normal extremity. The management of type-III injuries remains controversial and is individualized. While a return to the previous level of functional activity with nonsurgical treatment has been documented in a number of case series, surgical reduction and coracoclavicular ligament reconstruction has been associated with a favorable outcome and can be considered in patients who place high functional demands on their shoulders or in athletes who participate in overhead sports. Surgical management is indicated for high-grade (≥type IV) acromioclavicular joint injuries to achieve anatomic reduction of the acromioclavicular joint, reconstruction of the coracoclavicular ligaments, and repair of the deltotrapezial fascia. Outcomes after surgical reconstruction of the coracoclavicular ligaments have been satisfactory with regard to achieving pain relief and return to functional activities, but further improvements in the biomechanical strength of these

  14. Control of interfacial intermetallic compounds in Fe–Al joining by Zn addition

    Energy Technology Data Exchange (ETDEWEB)

    Yang, J. [Key Laboratory of Robot and Welding Automation of Jiangxi Province, School of Mechanical and Electrical Engineering, Nanchang University, Nanchang, Jiangxi 330031 (China); Center for Advanced Materials Joining, University of Waterloo, Waterloo, Ontario, Canada N2L 3G1 (Canada); Li, Y.L., E-mail: liyulong1112ster@gmail.com [Key Laboratory of Robot and Welding Automation of Jiangxi Province, School of Mechanical and Electrical Engineering, Nanchang University, Nanchang, Jiangxi 330031 (China); Zhang, H. [Key Laboratory of Robot and Welding Automation of Jiangxi Province, School of Mechanical and Electrical Engineering, Nanchang University, Nanchang, Jiangxi 330031 (China); Guo, W. [Center for Advanced Materials Joining, University of Waterloo, Waterloo, Ontario, Canada N2L 3G1 (Canada); School of Mechanical Engineering and Automation, Beijing University of Aeronautics and Astronautics, Beijing 100191 (China); Zhou, Y. [Center for Advanced Materials Joining, University of Waterloo, Waterloo, Ontario, Canada N2L 3G1 (Canada)

    2015-10-01

    By Zn addition to the fusion zone, the interfacial intermetallic compounds (IMCs) of laser Al/steel joint changed from layered Fe{sub 2}Al{sub 5} and needle-like FeAl{sub 3} to layered Fe{sub 2}Al{sub 5−x}Zn{sub x} and dispersed FeZn{sub 10} with minor Al-rich amorphous phase. This resulted in an improvement in the joint strength and the change of failure mode.

  15. [Classification and Treatment of Sacroiliac Joint Dislocation].

    Science.gov (United States)

    Tan, Zhen; Huang, Zhong; Li, Liang; Meng, Wei-Kun; Liu, Lei; Zhang, Hui; Wang, Guang-Lin; Huang, Fu-Guo

    2017-09-01

    To develop a renewed classification and treatment regimen for sacroiliac joint dislocation. According to the direction of dislocation of sacroiliac joint,combined iliac,sacral fractures,and fracture morphology,sacroiliac joint dislocation was classified into 4 types. Type Ⅰ (sacroiliac anterior dislocation): main fracture fragments of posterior iliac wing dislocated in front of sacroiliac joint. Type Ⅱ (sacroiliac posterior dislocation): main fracture fragments of posterior iliac wing dislocated in posterior of sacroiliac joint. Type Ⅲ (Crescent fracturedislocation of the sacroiliac joint): upward dislocation of posterior iliac wing with oblique fracture through posterior iliac wing. Type ⅢA: a large crescent fragment and dislocation comprises no more than onethird of sacroiliac joint,which is typically inferior. Type ⅢB: intermediatesize crescent fragment and dislocation comprises between one and twothirds of joint. Type ⅢC: a small crescent fragment where dislocation comprises most,but not the entire joint. Different treatment regimens were selected for different types of fractures. Treatment for type Ⅰ sacroiliac joint dislocation: anterior iliac fossa approach pry stripping reset; sacroiliac joint fixed with sacroiliac screw through percutaneous. Treatment for type Ⅱ sacroiliac joint dislocation: posterior sacroiliac joint posterior approach; sacroiliac joint fixed with sacroiliac screw under computer guidance. Treatment for type ⅢA and ⅢB sacroiliac joint dislocation: posterior sacroiliac joint approach; sacroiliac joint fixed with reconstruction plate. Treatment for type ⅢC sacroiliac joint dislocation: sacroiliac joint closed reduction; sacroiliac joint fixed with sacroiliac screw through percutaneous. Treatment for type Ⅳ sacroiliac joint dislocation: posterior approach; sacroiliac joint fixed with spinal pelvic fixation. Results of 24 to 72 months patient follow-up (mean 34.5 months): 100% survival,100% wound healing,and 100

  16. Compound semiconductor device modelling

    CERN Document Server

    Miles, Robert

    1993-01-01

    Compound semiconductor devices form the foundation of solid-state microwave and optoelectronic technologies used in many modern communication systems. In common with their low frequency counterparts, these devices are often represented using equivalent circuit models, but it is often necessary to resort to physical models in order to gain insight into the detailed operation of compound semiconductor devices. Many of the earliest physical models were indeed developed to understand the 'unusual' phenomena which occur at high frequencies. Such was the case with the Gunn and IMPATI diodes, which led to an increased interest in using numerical simulation methods. Contemporary devices often have feature sizes so small that they no longer operate within the familiar traditional framework, and hot electron or even quantum­ mechanical models are required. The need for accurate and efficient models suitable for computer aided design has increased with the demand for a wider range of integrated devices for operation at...

  17. Tripolar Mesoionic Compounds

    OpenAIRE

    Shuki, Araki; Jiro, Mizuya; Naomitsu, Aoyama; Yasuo, Butsugan

    1995-01-01

    Tripolar mesoionic compounds have been synthesized by the reaction of (1,3-diphenyltetrazol-5-ylio)cyclopentadienide (or -indenide) with the dicationic ether salts derived from mesoionic olates and trifluoromethanesulfonic anhydride. The structures of the newly prepared mesoionic systems are discussed on the basis of spectroscopic analysis; it is shown that the tripolar [tetrazolium-cyclopentadienide (or indenide)-tetrazolium] canonical structure contributes significantly to the ground state ...

  18. Oligosilanylated Antimony Compounds

    OpenAIRE

    Zitz, Rainer; Gatterer, Karl; Reinhold, Crispin R. W.; M?ller, Thomas; Baumgartner, Judith; Marschner, Christoph

    2015-01-01

    By reactions of magnesium oligosilanides with SbCl3, a number of oligosilanylated antimony compounds were obtained. When oligosilanyl dianions were used, either the expected cyclic disilylated halostibine was obtained or alternatively the formation of a distibine was observed. Deliberate formation of the distibine from the disilylated halostibine was achieved by reductive coupling with C8K. Computational studies of Sb?Sb bond energies, barriers of pyramidal inversion at Sb, and the conformati...

  19. Labelled compounds. (Pt. B)

    International Nuclear Information System (INIS)

    Buncel, E.; Jones, J.R.

    1991-01-01

    Since the end of World War II there has been a tremendous increase in the number of compounds that have been synthesized with radioactive or stable isotopes. They have found application in many diverse fields, so much so, that hardly a single area in pure and applied science has not benefited. Not surprisingly it has been reflected in appearance of related publications. The early proceedings of the Symposia on Advances in Trace Methodology were soon followed by various Euratom sponsored meetings in which methods of preparing and storing labelled compounds featured prominently. In due course a resurgence of interest in stable isotopes, brought about by their greater availability (also lower cost) and partly by development of new techniques such as gas chromatography - mass spectrometry (gc-ms), led to the publication of proceedings of several successful conferences. More recently conferences dealing with the synthesis and applications of isotopes and isotopically labelled compounds have been established on a regular basis. In addition to the proceedings of conferences and journal publications individuals left their mark by producing definitive texts, usually on specific nuclides. Only the classic two volume publication of Murray and Williams (Organic syntheses with isotopes, New York 1985), now over 30 years old and out of print, attempted to do justice to several nuclides. With the large amount of work that has been undertaken since then it seems unlikely that an updated edition could be produced. The alternative strategy was to ask scientists currently active to review specific areas and this is the approach adopted in the present series of monographs. In this way it is intended to cover the broad advances that have been made in the synthesis and applications of isotopes and isotopically labelled compounds in the physical and biomedical sciences. (author). refs.; figs.; tabs

  20. Process for compound transformation

    KAUST Repository

    Basset, Jean-Marie

    2016-12-29

    Embodiments of the present disclosure provide for methods of using a catalytic system to chemically transform a compound (e.g., a hydrocarbon). In an embodiment, the method does not employ grafting the catalyst prior to catalysis. In particular, embodiments of the present disclosure provide for a process of hydrocarbon (e.g., C1 to C20 hydrocarbon) metathesis (e.g., alkane, olefin, or alkyne metathesis) transformation, where the process can be conducted without employing grafting prior to catalysis.

  1. Compound Semiconductor Radiation Detector

    International Nuclear Information System (INIS)

    Kim, Y. K.; Park, S. H.; Lee, W. G.; Ha, J. H.

    2005-01-01

    In 1945, Van Heerden measured α, β and γ radiations with the cooled AgCl crystal. It was the first radiation measurement using the compound semiconductor detector. Since then the compound semiconductor has been extensively studied as radiation detector. Generally the radiation detector can be divided into the gas detector, the scintillator and the semiconductor detector. The semiconductor detector has good points comparing to other radiation detectors. Since the density of the semiconductor detector is higher than that of the gas detector, the semiconductor detector can be made with the compact size to measure the high energy radiation. In the scintillator, the radiation is measured with the two-step process. That is, the radiation is converted into the photons, which are changed into electrons by a photo-detector, inside the scintillator. However in the semiconductor radiation detector, the radiation is measured only with the one-step process. The electron-hole pairs are generated from the radiation interaction inside the semiconductor detector, and these electrons and charged ions are directly collected to get the signal. The energy resolution of the semiconductor detector is generally better than that of the scintillator. At present, the commonly used semiconductors as the radiation detector are Si and Ge. However, these semiconductor detectors have weak points. That is, one needs thick material to measure the high energy radiation because of the relatively low atomic number of the composite material. In Ge case, the dark current of the detector is large at room temperature because of the small band-gap energy. Recently the compound semiconductor detectors have been extensively studied to overcome these problems. In this paper, we will briefly summarize the recent research topics about the compound semiconductor detector. We will introduce the research activities of our group, too

  2. Bronzes and relative compounds

    International Nuclear Information System (INIS)

    Uehlls, A.

    1987-01-01

    Preparation and the crystal structure of bronzes based on complex oxides of transition (Ti, V, Nb, Ta, Mo, W, Re, Ru and etc.) and alkali metals, as well as oxides of some other elements (Sr, In, La and etc.) are described. Peculiarities of formation of the structure of tetragonal, tungsten, molybdenum, vanadium bronzes and their analogs depending on the chemical composition of these compounds are considered

  3. Compound Wiretap Channels

    Directory of Open Access Journals (Sweden)

    Shlomo Shamai (Shitz

    2009-01-01

    Full Text Available This paper considers the compound wiretap channel, which generalizes Wyner's wiretap model to allow the channels to the (legitimate receiver and to the eavesdropper to take a number of possible states. No matter which states occur, the transmitter guarantees that the receiver decodes its message and that the eavesdropper is kept in full ignorance about the message. The compound wiretap channel can also be viewed as a multicast channel with multiple eavesdroppers, in which the transmitter sends information to all receivers and keeps the information secret from all eavesdroppers. For the discrete memoryless channel, lower and upper bounds on the secrecy capacity are derived. The secrecy capacity is established for the degraded channel and the semideterministic channel with one receiver. The parallel Gaussian channel is further studied. The secrecy capacity and the secrecy degree of freedom (s.d.o.f. are derived for the degraded case with one receiver. Schemes to achieve the s.d.o.f. for the case with two receivers and two eavesdroppers are constructed to demonstrate the necessity of a prefix channel in encoder design. Finally, the multi-antenna (i.e., MIMO compound wiretap channel is studied. The secrecy capacity is established for the degraded case and an achievable s.d.o.f. is given for the general case.

  4. Antifungal compounds from cyanobacteria.

    Science.gov (United States)

    Shishido, Tânia K; Humisto, Anu; Jokela, Jouni; Liu, Liwei; Wahlsten, Matti; Tamrakar, Anisha; Fewer, David P; Permi, Perttu; Andreote, Ana P D; Fiore, Marli F; Sivonen, Kaarina

    2015-04-13

    Cyanobacteria are photosynthetic prokaryotes found in a range of environments. They are infamous for the production of toxins, as well as bioactive compounds, which exhibit anticancer, antimicrobial and protease inhibition activities. Cyanobacteria produce a broad range of antifungals belonging to structural classes, such as peptides, polyketides and alkaloids. Here, we tested cyanobacteria from a wide variety of environments for antifungal activity. The potent antifungal macrolide scytophycin was detected in Anabaena sp. HAN21/1, Anabaena cf. cylindrica PH133, Nostoc sp. HAN11/1 and Scytonema sp. HAN3/2. To our knowledge, this is the first description of Anabaena strains that produce scytophycins. We detected antifungal glycolipopeptide hassallidin production in Anabaena spp. BIR JV1 and HAN7/1 and in Nostoc spp. 6sf Calc and CENA 219. These strains were isolated from brackish and freshwater samples collected in Brazil, the Czech Republic and Finland. In addition, three cyanobacterial strains, Fischerella sp. CENA 298, Scytonema hofmanni PCC 7110 and Nostoc sp. N107.3, produced unidentified antifungal compounds that warrant further characterization. Interestingly, all of the strains shown to produce antifungal compounds in this study belong to Nostocales or Stigonematales cyanobacterial orders.

  5. Toxic compounds in honey.

    Science.gov (United States)

    Islam, Md Nazmul; Khalil, Md Ibrahim; Islam, Md Asiful; Gan, Siew Hua

    2014-07-01

    There is a wealth of information about the nutritional and medicinal properties of honey. However, honey may contain compounds that may lead to toxicity. A compound not naturally present in honey, named 5-hydroxymethylfurfural (HMF), may be formed during the heating or preservation processes of honey. HMF has gained much interest, as it is commonly detected in honey samples, especially samples that have been stored for a long time. HMF is a compound that may be mutagenic, carcinogenic and cytotoxic. It has also been reported that honey can be contaminated with heavy metals such as lead, arsenic, mercury and cadmium. Honey produced from the nectar of Rhododendron ponticum contains alkaloids that can be poisonous to humans, while honey collected from Andromeda flowers contains grayanotoxins, which can cause paralysis of limbs in humans and eventually leads to death. In addition, Melicope ternata and Coriaria arborea from New Zealand produce toxic honey that can be fatal. There are reports that honey is not safe to be consumed when it is collected from Datura plants (from Mexico and Hungary), belladonna flowers and Hyoscamus niger plants (from Hungary), Serjania lethalis (from Brazil), Gelsemium sempervirens (from the American Southwest), Kalmia latifolia, Tripetalia paniculata and Ledum palustre. Although the symptoms of poisoning due to honey consumption may differ depending on the source of toxins, most common symptoms generally include dizziness, nausea, vomiting, convulsions, headache, palpitations or even death. It has been suggested that honey should not be considered a completely safe food. Copyright © 2013 John Wiley & Sons, Ltd.

  6. Antifungal Compounds from Cyanobacteria

    Directory of Open Access Journals (Sweden)

    Tânia K. Shishido

    2015-04-01

    Full Text Available Cyanobacteria are photosynthetic prokaryotes found in a range of environments. They are infamous for the production of toxins, as well as bioactive compounds, which exhibit anticancer, antimicrobial and protease inhibition activities. Cyanobacteria produce a broad range of antifungals belonging to structural classes, such as peptides, polyketides and alkaloids. Here, we tested cyanobacteria from a wide variety of environments for antifungal activity. The potent antifungal macrolide scytophycin was detected in Anabaena sp. HAN21/1, Anabaena cf. cylindrica PH133, Nostoc sp. HAN11/1 and Scytonema sp. HAN3/2. To our knowledge, this is the first description of Anabaena strains that produce scytophycins. We detected antifungal glycolipopeptide hassallidin production in Anabaena spp. BIR JV1 and HAN7/1 and in Nostoc spp. 6sf Calc and CENA 219. These strains were isolated from brackish and freshwater samples collected in Brazil, the Czech Republic and Finland. In addition, three cyanobacterial strains, Fischerella sp. CENA 298, Scytonema hofmanni PCC 7110 and Nostoc sp. N107.3, produced unidentified antifungal compounds that warrant further characterization. Interestingly, all of the strains shown to produce antifungal compounds in this study belong to Nostocales or Stigonematales cyanobacterial orders.

  7. Compound Wiretap Channels

    Directory of Open Access Journals (Sweden)

    Kramer Gerhard

    2009-01-01

    Full Text Available Abstract This paper considers the compound wiretap channel, which generalizes Wyner's wiretap model to allow the channels to the (legitimate receiver and to the eavesdropper to take a number of possible states. No matter which states occur, the transmitter guarantees that the receiver decodes its message and that the eavesdropper is kept in full ignorance about the message. The compound wiretap channel can also be viewed as a multicast channel with multiple eavesdroppers, in which the transmitter sends information to all receivers and keeps the information secret from all eavesdroppers. For the discrete memoryless channel, lower and upper bounds on the secrecy capacity are derived. The secrecy capacity is established for the degraded channel and the semideterministic channel with one receiver. The parallel Gaussian channel is further studied. The secrecy capacity and the secrecy degree of freedom ( are derived for the degraded case with one receiver. Schemes to achieve the for the case with two receivers and two eavesdroppers are constructed to demonstrate the necessity of a prefix channel in encoder design. Finally, the multi-antenna (i.e., MIMO compound wiretap channel is studied. The secrecy capacity is established for the degraded case and an achievable is given for the general case.

  8. Rheumatoid arthritis affecting temporomandibular joint

    Directory of Open Access Journals (Sweden)

    Amandeep Sodhi

    2015-01-01

    Full Text Available Rheumatoid arthritis (RA is a chronic, systemic, autoimmune inflammatory disorder that is characterized by joint inflammation, erosive properties and symmetric multiple joint involvement. Temporomandibular joint (TMJ is very rare to be affected in the early phase of the disease, thus posing diagnostic challenges for the dentist. Conventional radiographs fail to show the early lesions due to its limitations. More recently cone-beam computed tomography (CBCT has been found to diagnose the early degenerative changes of TMJ and hence aid in the diagnosis of the lesions more accurately. Our case highlights the involvement of TMJ in RA and the role of advanced imaging (CBCT in diagnosing the bony changes in the early phase of the disease.

  9. Leaving a joint audit system

    DEFF Research Database (Denmark)

    Holm, Claus; Thinggaard, Frank

    2014-01-01

    determinants model and an audit fee change model and include interaction terms. Findings: The authors find short-term fee reductions in companies switching to single audits, but only where the former joint audit contained a dominant auditor. The authors argue that in this situation bargaining power is more...... with the auditors than in a equally shared joint audit, and that the auditors' incentives to offer an initial fee discount are bigger. Research limitations/implications: The number of observations is constrained by the small Danish capital market. Future research could take a more qualitative research approach......, to examine whether the use of a single audit firm rather than two has an effect on audit quality. The area calls for further theory development covering audit fee and audit quality in joint audit settings. Practical implications: Comapnies should consider their relationship with their auditors before...

  10. Joint US/German Conference

    CERN Document Server

    Gulledge, Thomas; Jones, Albert

    1993-01-01

    This proceedings volume contains selected and refereed contributions that were presented at the conference on "Recent Developments and New Perspectives of Operations Research in the Area of Production Planning and Control" in Hagen/Germany, 25. - 26. June 1992. This conference was organized with the cooperation of the FernuniversiHit Hagen and was jointly hosted by the "Deutsche Gesellschaft fur Operations Research (DGOR)" and the "Manufacturing Special Interest Group of the Operations Research Society of America (ORSA-SIGMA)". For the organization of the conference we received generous financial support from the sponsors listed at the end of this volume. We wish to express our appreciation to all supporters for their contributions. This conference was the successor of the JOInt ORSA/DGOR-conference in Gaithersburg/Maryland, USA, on the 30. and 31. July 1991. Both OR-societies committed themselves in 1989 to host joint conferences on special topics of interest from the field of operations research. This goal ...

  11. Modeling Compound Flood Hazards in Coastal Embayments

    Science.gov (United States)

    Moftakhari, H.; Schubert, J. E.; AghaKouchak, A.; Luke, A.; Matthew, R.; Sanders, B. F.

    2017-12-01

    Coastal cities around the world are built on lowland topography adjacent to coastal embayments and river estuaries, where multiple factors threaten increasing flood hazards (e.g. sea level rise and river flooding). Quantitative risk assessment is required for administration of flood insurance programs and the design of cost-effective flood risk reduction measures. This demands a characterization of extreme water levels such as 100 and 500 year return period events. Furthermore, hydrodynamic flood models are routinely used to characterize localized flood level intensities (i.e., local depth and velocity) based on boundary forcing sampled from extreme value distributions. For example, extreme flood discharges in the U.S. are estimated from measured flood peaks using the Log-Pearson Type III distribution. However, configuring hydrodynamic models for coastal embayments is challenging because of compound extreme flood events: events caused by a combination of extreme sea levels, extreme river discharges, and possibly other factors such as extreme waves and precipitation causing pluvial flooding in urban developments. Here, we present an approach for flood risk assessment that coordinates multivariate extreme analysis with hydrodynamic modeling of coastal embayments. First, we evaluate the significance of correlation structure between terrestrial freshwater inflow and oceanic variables; second, this correlation structure is described using copula functions in unit joint probability domain; and third, we choose a series of compound design scenarios for hydrodynamic modeling based on their occurrence likelihood. The design scenarios include the most likely compound event (with the highest joint probability density), preferred marginal scenario and reproduced time series of ensembles based on Monte Carlo sampling of bivariate hazard domain. The comparison between resulting extreme water dynamics under the compound hazard scenarios explained above provides an insight to the

  12. Evaluation of Rock Joint Coefficients

    Science.gov (United States)

    Audy, Ondřej; Ficker, Tomáš

    2017-10-01

    A computer method for evaluation of rock joint coefficients is described and several applications are presented. The method is based on two absolute numerical indicators that are formed by means of the Fourier replicas of rock joint profiles. The first indicator quantifies the vertical depth of profiles and the second indicator classifies wavy character of profiles. The absolute indicators have replaced the formerly used relative indicators that showed some artificial behavior in some cases. This contribution is focused on practical computations testing the functionality of the newly introduced indicators.

  13. [Divorce and joint physical custody].

    Science.gov (United States)

    Golse, B

    2014-04-01

    This work first recalls the definition of joint physical custody, as well as the current legal procedure for obtaining it, its practical implementation, the financial implications for parents, and finally some statistics. Some psychological and psychopathological reflections on the impact of divorce on children are then presented before considering the question of joint physically custody with regard to attachment theory and depending on the age of the child (a great caution seems to be required before three years). The article concludes with a brief discussion of parental alienation syndrome. Copyright © 2014. Published by Elsevier SAS.

  14. What Determines Joint Venture Termination?

    DEFF Research Database (Denmark)

    Nielsen, Bo Bernhard

    2012-01-01

    Joint venture (JV) research continues to flourish as researchers seek to advance our understanding of why so many JVs fail. Cui and Kumar (this issue) take a contingency approach to explain how and why business relatedness may provide new insights as to what determines JV termination. This commen......Joint venture (JV) research continues to flourish as researchers seek to advance our understanding of why so many JVs fail. Cui and Kumar (this issue) take a contingency approach to explain how and why business relatedness may provide new insights as to what determines JV termination...

  15. Dual joint space arthrography in temporomandibular joint disorders: Comparison with single inferior joint space arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyung Sik; Chang, Duk Soo; Lee, Kyung Soo; Kim, Woo Sun; Sung, Jung Ho; Jun, Young Hwan [Capital Armed Forces General Hospital, Seoul (Korea, Republic of)

    1989-02-15

    The temporomandibular joint(TMJ) is really a complex of two synovial space separated by fibrocartilaginous disc. Single inferior joint space arthrography is commonly performed for evaluation of TMJ disorders, which is known to be superior in demonstrating joint dynamics. But it reveals only the inferior surface of the disc. Therefore, dual space arthrography is superior to demonstrate the soft tissue anatomic feature of the joint such as disc position and shape. Authors performed 83 TMJ arthrograms in TMJ problems. Initially, the inferior joint space was done and then the superior space was sequentially contrasted. The follow results were noted: 1. In all cases, dual space arthrography revealed accurate disc shape and positions. 2. Concordant findings between the two techniques: 68 cases (82%). Discordance between the two techniques: 15 cases (18%) 3. Possible causes of discordance between inferior and dual space arthrography. a) Normal varians of anterior recess: 3 cases b) Posterior disc displacement: 4 cases c) Influence of the patient's head position change :4 cases d) False perforation: 2 cases e) Reduction change: 2 cases 4. In 5 cases with anterior displacement, dual space arthrography gave additional findings such as adhesion within the superior space, which could not be evaluated by single inferior space.

  16. Nomenclature on an inorganic compound

    International Nuclear Information System (INIS)

    1998-10-01

    This book contains eleven chapters : which mention nomenclature of an inorganic compound with introduction and general principle on nomenclature of compound. It gives the description of grammar for nomenclature such as brackets, diagonal line, asterisk, and affix, element, atom and groups of atom, chemical formula, naming by stoichiometry, solid, neutral molecule compound, ion, a substituent, radical and name of salt, oxo acid and anion on introduction and definition of oxo acid, coordination compound like symbol of stereochemistry , boron and hydrogen compound and related compound.

  17. [Meniscoids of the intervertebral joints].

    Science.gov (United States)

    Kos, J; Hert, J; Sevcík, P

    2002-01-01

    A large amount of material was used to study the distribution, location and shape of meniscoids in intervertebral joints of the human spine, from the atlanto-occipital joint to the sacrum, in order to find out how many of intervertebral joints had mobile meniscoids. These might be regarded as possible causes of spinal blockade or other vertebrogenous complaints. The materials provided by the Department of Anatomy and Department of Forensic Medicine at the Faculty of Medicine of Charles University in Pilznen included 20 cadaverous spines from humans aged 20 to 80 years. Access to each joint was provided by dissection of the articular capsule from the lower articular processes of the vertebra situated above. In the orthograde view, all meniscoids were described in terms of shape, size, consistence and location. Their structure was ascertained by histological examination of cross sections stained with haematoxylin and eosin. Meniscoids varying in shape and size were found in all of the intervertebral joints. They were classified by their histological structure as synovial, fat and fibrous meniscoids. The first category was observed frequently, the last only rarely. A total of 29 mobile meniscoids were recorded, most of them in the lumbar spine. Most of the meniscoids present in the cervical spine were of synovial and less frequently of fat types. Meniscoids found in the thoracic spine were poorly developed synovial ones and those present in the lumbar spine were of all types and were also largest in size. The most conspicuous meniscoids were seen in the spines that showed degenerative changes in intervertebral joints. Large fat pads were found in atlanto-occipital and atlanto-axial joints. Mobile meniscoids, most of them present in the lumbar spine (6.4% of all joints.), were connected with the capsule by a thin pedicle and it was possible to move them over a half of the articular surface. Some inter-individual changes were also found; in some spines, the most

  18. Study of failure mechanism of double-lap joints of steel to FRP by bolt and resin

    Directory of Open Access Journals (Sweden)

    Amir Hossein Zakeri

    2017-05-01

    Full Text Available In this study, the behavior of joints in two sides of steel coat which are screwed to the composite plate, and joints of two sides of compound steel coat (bolted and bonded to the composite plate has been studied. In the standards, distance of mechanical bolts from the edges and the distance of mechanical bolts from each other have been discussed. Different distances in the range of the standards determined for the distance of screws from edges and screws from each other. In this paper, the screw joints and the combined joints with different terminal distances for screws from the edges are modeled and studied. The results showed the basic effects of the terminal distance of the screw from the connection edges on the resistance and mechanism of break of screw joints. In combined joints, the terminal distance of the screw had trivial effects in the resistance and mechanism of joint break. In addition, overlap length of the connection elements on increase of joint resistance analyzed and studied. To do so, a combined joint with configuration of two steel plates and one CFRP/GFRP composite plates which were joined by two screws and adhesive layers with different overlap were modeled. The results showed the direct relationship between increase of overlap length and increase in resistance of the joint. Finally, a design guide to be used in practice was proposed.

  19. Offset Compound Gear Drive

    Science.gov (United States)

    Stevens, Mark A.; Handschuh, Robert F.; Lewicki, David G.

    2010-01-01

    The Offset Compound Gear Drive is an in-line, discrete, two-speed device utilizing a special offset compound gear that has both an internal tooth configuration on the input end and external tooth configuration on the output end, thus allowing it to mesh in series, simultaneously, with both a smaller external tooth input gear and a larger internal tooth output gear. This unique geometry and offset axis permits the compound gear to mesh with the smaller diameter input gear and the larger diameter output gear, both of which are on the same central, or primary, centerline. This configuration results in a compact in-line reduction gear set consisting of fewer gears and bearings than a conventional planetary gear train. Switching between the two output ratios is accomplished through a main control clutch and sprag. Power flow to the above is transmitted through concentric power paths. Low-speed operation is accomplished in two meshes. For the purpose of illustrating the low-speed output operation, the following example pitch diameters are given. A 5.0 pitch diameter (PD) input gear to 7.50 PD (internal tooth) intermediate gear (0.667 reduction mesh), and a 7.50 PD (external tooth) intermediate gear to a 10.00 PD output gear (0.750 reduction mesh). Note that it is not required that the intermediate gears on the offset axis be of the same diameter. For this example, the resultant low-speed ratio is 2:1 (output speed = 0.500; product of stage one 0.667 reduction and stage two 0.750 stage reduction). The design is not restricted to the example pitch diameters, or output ratio. From the output gear, power is transmitted through a hollow drive shaft, which, in turn, drives a sprag during which time the main clutch is disengaged.

  20. Prosthesis of the wrist-joint

    Energy Technology Data Exchange (ETDEWEB)

    Feldmeier, C.

    1983-02-25

    Function of the hand-joint and the well-being of patients can be severely affected by arthrosis of the wrist-joint. Therapeutically, arthrodesis usually results in a painfree status of stiffness. A painless and well functioning joint can be achieved by alloplastic joint replacement or resurfacing. The possibilities and clinical results in cases of arthrosis of the carpo-metacarpal joint of the thumb, pseudarthrosis of the scaphoid, aseptic necrosis of the Lunate and severe arthrosis of the radio-carpal joint are demonstrated.

  1. Prosthesis of the wrist-joint

    International Nuclear Information System (INIS)

    Feldmeier, C.

    1983-01-01

    Function of the hand-joint and the well-being of patients can be severely affected by arthrosis of the wrist-joint. Therapeutically, arthrodesis usually results in a painfree status of stiffness. A painless and well functioning joint can be achieved by alloplastic joint replacement or resurfacing. The possibilities and clinical results in cases of arthrosis of the carpo-metacarpal joint of the thumb, pseudarthrosis of the scaphoid, aseptic necrosis of the Lunate and severe arthrosis of the radio-carpal joint are demonstrated. (orig.) [de

  2. A Modelling Method of Bolt Joints Based on Basic Characteristic Parameters of Joint Surfaces

    Science.gov (United States)

    Yuansheng, Li; Guangpeng, Zhang; Zhen, Zhang; Ping, Wang

    2018-02-01

    Bolt joints are common in machine tools and have a direct impact on the overall performance of the tools. Therefore, the understanding of bolt joint characteristics is essential for improving machine design and assembly. Firstly, According to the experimental data obtained from the experiment, the stiffness curve formula was fitted. Secondly, a finite element model of unit bolt joints such as bolt flange joints, bolt head joints, and thread joints was constructed, and lastly the stiffness parameters of joint surfaces were implemented in the model by the secondary development of ABAQUS. The finite element model of the bolt joint established by this method can simulate the contact state very well.

  3. Toxicology of alkylmercury compounds.

    Science.gov (United States)

    Aschner, Michael; Onishchenko, Natalia; Ceccatelli, Sandra

    2010-01-01

    Methylmercury is a global pollutant and potent neurotoxin whose abundance in the food chain mandates additional studies on the consequences and mechanisms of its toxicity to the central nervous system. Formulation of our new hypotheses was predicated on our appreciation for (a) the remarkable affinity of mercurials for the anionic form of sulfhydryl (-SH) groups, and (b) the essential role of thiols in protein biochemistry. The present chapter addresses pathways to human exposure of various mercury compounds, highlighting their neurotoxicity and potential involvement in neurotoxic injury and neurodegenerative changes, both in the developing and senescent brain. Mechanisms that trigger these effects are discussed in detail.

  4. Compound composite odontoma

    Directory of Open Access Journals (Sweden)

    S Kailasam

    2012-01-01

    Full Text Available Odontomas are the most common type of odontogenic tumors and generally they are asymptomatic. Frequently, it may interfere with the eruption of the teeth. This is a case report of a compound composite odontoma in a 10-year-old girl, which results in failure of eruption of the permanent upper right central incisor while the contralateral tooth had erupted. A calcified mass was seen in the radiograph and was provisionally diagnosed as odontoma following which the odontoma was enucleated. Routine follow-up was done for more than a year and no recurrence was seen. This case report indicates that early diagnosis and management ensures better prognosis.

  5. Flavour Compounds in Fungi

    DEFF Research Database (Denmark)

    Ravasio, Davide Antonio

    . This selection of strains was used in fermentations with the aim of identifying new interesting flavour producers. Fermentation profiles, volatile analyses, off-flavour identification and resistance to osmotic/oxidative stress have been addressed to highlight new candidates to use for industrial applications....... This resulted in the identification of Wickerhamomyces anomalus and Pichia kluyveri as high producers of esters fruity compounds, which contribute to enhance the complexity of wine and beer product. In addition the strain Debaromyces subglobosus showed high yields of aldehydes and fruity ketones, which...

  6. Antifouling Compounds from Marine Invertebrates.

    Science.gov (United States)

    Qi, Shu-Hua; Ma, Xuan

    2017-08-28

    In this review, a comprehensive overview about the antifouling compounds from marine invertebrates is described. In total, more than 198 antifouling compounds have been obtained from marine invertebrates, specifically, sponges, gorgonian and soft corals.

  7. Antifouling Compounds from Marine Invertebrates

    OpenAIRE

    Qi, Shu-Hua; Ma, Xuan

    2017-01-01

    In this review, a comprehensive overview about the antifouling compounds from marine invertebrates is described. In total, more than 198 antifouling compounds have been obtained from marine invertebrates, specifically, sponges, gorgonian and soft corals.

  8. Joint Attention and Anthropological Difference

    Czech Academy of Sciences Publication Activity Database

    Urban, Petr

    2014-01-01

    Roč. 11, č. 1 (2014), s. 59-70 ISSN 1718-0198 R&D Projects: GA ČR GAP401/10/1164 Institutional support: RVO:67985955 Keywords : joint attention * anthropological difference * phenomenology * great apes * shared intentionality Subject RIV: AA - Philosophy ; Religion

  9. National Guard Bureau Joint Staff

    Science.gov (United States)

    Civic Leader's Guide ARNG Vision 2020 Posture Statement Strategic Direction CNGB ARNG Financial Report Marshal Office of the Joint Surgeon PARC Small Business Programs Chaplain Diversity NGB-GOMO Resources Legislative Liaison Small Business Programs Social Media State Websites Videos Featured Videos On Every Front

  10. Recruitment of knee joint ligaments

    NARCIS (Netherlands)

    Blankevoort, L.; Huiskes, H.W.J.; Lange, de A.

    1991-01-01

    On the basis of earlier reported data on the in vitro kinematics of passive knee-joint motions of four knee specimens, the length changes of ligament fiber bundles were determined by using the points of insertion on the tibia and femur. The kinematic data and the insertions of the ligaments were

  11. Durability of building joint sealants

    Science.gov (United States)

    Christopher C. White; Kar Tean Tan; Donald L. Hunston; R. Sam Williams

    2009-01-01

    Predicting the service life of building joint sealants exposed to service environments in less than real time has been a need of the sealant community for many decades. Despite extensive research efforts to design laboratory accelerated tests to duplicate the failure modes occurring in field exposures, little success has been achieved using conventional durability...

  12. Multilevel joint competing risk models

    Science.gov (United States)

    Karunarathna, G. H. S.; Sooriyarachchi, M. R.

    2017-09-01

    Joint modeling approaches are often encountered for different outcomes of competing risk time to event and count in many biomedical and epidemiology studies in the presence of cluster effect. Hospital length of stay (LOS) has been the widely used outcome measure in hospital utilization due to the benchmark measurement for measuring multiple terminations such as discharge, transferred, dead and patients who have not completed the event of interest at the follow up period (censored) during hospitalizations. Competing risk models provide a method of addressing such multiple destinations since classical time to event models yield biased results when there are multiple events. In this study, the concept of joint modeling has been applied to the dengue epidemiology in Sri Lanka, 2006-2008 to assess the relationship between different outcomes of LOS and platelet count of dengue patients with the district cluster effect. Two key approaches have been applied to build up the joint scenario. In the first approach, modeling each competing risk separately using the binary logistic model, treating all other events as censored under the multilevel discrete time to event model, while the platelet counts are assumed to follow a lognormal regression model. The second approach is based on the endogeneity effect in the multilevel competing risks and count model. Model parameters were estimated using maximum likelihood based on the Laplace approximation. Moreover, the study reveals that joint modeling approach yield more precise results compared to fitting two separate univariate models, in terms of AIC (Akaike Information Criterion).

  13. Joint Advisory Appeals Board report

    CERN Document Server

    Lalande, Amanda

    2018-01-01

    With regard to the internal appeal procedure, Article R VI 1.18 of the Staff Rules and Regulations states that unless the member of the personnel objects, (the) decision and report of the JAAB (Joint Advisory Appeals Board) shall be brought to the attention of the members of the personnel.

  14. Imaging of hip joint arthroplasty

    International Nuclear Information System (INIS)

    Mayerhoefer, M.E.; Fruehwald-Pallamar, J.; Czerny, C.

    2009-01-01

    The hip joint is the largest joint in the human body and consequently, its evaluation by diagnostic imaging is highly important. This includes imaging of hip joint arthroplasty, which is used to avoid joint immobility following a wide spectrum of diseases, such as end-stage degenerative disease, avascular necrosis of the femoral head or post-traumatic fractures. Conventional radiography is still the standard imaging modality for the evaluation of hip arthroplasty both directly following surgery and for periodical follow-up. In the majority of cases conventional radiography enables adequate assessment of early and late complications that can arise following hip arthroplasty, such as loosening, prosthetic or periprosthetic fracture, luxation, infection and soft tissue calcification. If the diagnosis cannot be established by means of radiography, advanced imaging methods such as computed tomography (CT) and magnetic resonance imaging (MRI), with or without injection of contrast media, may provide additional information. This is particularly true for the depiction of inflammatory processes. Regardless of the imaging modality used patients' clinical symptoms must also be taken into account in order to establish the correct diagnosis. (orig.) [de

  15. UK manufacturers construction joint venture

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    This report examines the legal and commercial framework for UK manufacturers to collaborate in a construction venture for a small combustion/steam cycle power plant fueled with biomass. The integration of technology and project plan, the working capital and capitalisation, financial aspects, the market plan, turnkey packages, joint venture entities, and collaboration are discussed. (UK)

  16. Compound Passport Service: supporting corporate collection owners in open innovation.

    Science.gov (United States)

    Andrews, David M; Degorce, Sébastien L; Drake, David J; Gustafsson, Magnus; Higgins, Kevin M; Winter, Jon J

    2015-10-01

    A growing number of early discovery collaborative agreements are being put in place between large pharma companies and partners in which the rights for assets can reside with a partner, exclusively or jointly. Our corporate screening collection, like many others, was built on the premise that compounds generated in-house and not the subject of paper or patent disclosure were proprietary to the company. Collaborative screening arrangements and medicinal chemistry now make the origin, ownership rights and usage of compounds difficult to determine and manage. The Compound Passport Service is a dynamic database, managed and accessed through a set of reusable services that borrows from social media concepts to allow sample owners to take control of their samples in a much more active way. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Catalytic properties of niobium compounds

    International Nuclear Information System (INIS)

    Tanabe, K.; Iizuka, T.

    1983-04-01

    The catalytic activity and selectivity of niobium compounds including oxides, salts, organometallic compounds and others are outlined. The application of these compounds as catalysts to diversified reactions is reported. The nature and action of niobium catalysts are characteristic and sometimes anomalous, suggesting the necessity of basic research and the potential use as catalysts for important processes in the chemical industry. (Author) [pt

  18. Molecular modeling of inorganic compounds

    National Research Council Canada - National Science Library

    Comba, Peter; Hambley, Trevor W; Martin, Bodo

    2009-01-01

    ... mechanics to inorganic and coordination compounds. Initially, simple metal complexes were modeled, but recently the field has been extended to include organometallic compounds, catalysis and the interaction of metal ions with biological macromolecules. The application of molecular mechanics to coordination compounds is complicated by the numbe...

  19. Organometallic compounds in the environment

    National Research Council Canada - National Science Library

    Craig, P. J

    2003-01-01

    ... of Organometallic Species in the Environment 20 1.10 Stability of Organometallic Compounds in Biological Systems 1.11 G eneral Comments on the Toxicities of Organometallic Compounds 22 1.12 General Considerations on Environmental R eactivity of Organometallic Compounds 24 1.13 Microbial Biotransformation of Metals and M etalloids 25 1.13.1 Introduction 25 1...

  20. Goldenphilicity: Luminescent gold compounds

    International Nuclear Information System (INIS)

    Sansores, L.E.

    2002-01-01

    In the solids and molecules different types of bonds are presented depending on the involved atoms, covalent bonds are common among elements of open shell, where more bond orbitals are filled than anti bond orbitals. It is expected that ionic bonds among closed shell atoms which have charges of opposite sign. Bonds type Van der Waals are presented among molecules which have a bipolar moment. It would not be expected bonds among zero charge species, or more generally with the same nominal charge and in any case the attractive forces would be very small. In fact it is expected that two metallic cations to be repelled each other. There recently is evidence that in organic or organometallic compounds could exist attractive interactions between two cations of the d 8 -d 10 -s 2 families. These bonds are weak but stronger than those of Van der Waals. They are compared with the hydrogen bonds. In this work it was reviewed some examples in which the goldenphilicity plays an important role in the luminescence that the gold complexes present. Examples of mono, bi and trinuclear and the structures that these organometallic compounds could take are examined. (Author)

  1. Microstructure and mechanical properties of weld-bonded and resistance spot welded magnesium-to-steel dissimilar joints

    International Nuclear Information System (INIS)

    Xu, W.; Chen, D.L.; Liu, L.; Mori, H.; Zhou, Y.

    2012-01-01

    Highlights: ► Adhesive reduces shrinkage porosity and stress concentration around the weld nugget. ► Adhesive promotes the formation of intermetallic compounds during weld bonding. ► In Mg/steel joints fusion zone appears only at the Mg side with dendritic structures. ► Weld-bonded Mg/steel joints are considerably stronger than RSW Mg/steel joints. ► Fatigue strength is three-fold higher for weld-bonded joints than for RSW joints. - Abstract: The aim of this study was to evaluate microstructures, tensile and fatigue properties of weld-bonded (WB) magnesium-to-magnesium (Mg/Mg) similar joints and magnesium-to-steel (Mg/steel) dissimilar joints, in comparison with resistance spot welded (RSW) Mg/steel dissimilar joints. In the WB Mg/Mg joints, equiaxed dendritic and divorced eutectic structures formed in the fusion zone (FZ). In the dissimilar joints of RSW and WB Mg/steel, FZ appeared only at Mg side with equiaxed and columnar dendrites. At steel side no microstructure changed in the WB Mg/steel joints, while the microstructure in the RSW Mg/steel joints consisted of lath martensite, bainite, pearlite and retained austenite leading to an increased microhardness. The relatively low cooling rate suppressed the formation of shrinkage porosity but promoted the formation of MgZn 2 and Mg 7 Zn 3 in the WB Mg/steel joints. The added adhesive layer diminished stress concentration around the weld nugget. Both WB Mg/Mg and Mg/steel joints were significantly stronger than RSW Mg/steel joints in terms of the maximum tensile shear load and energy absorption, which also increased with increasing strain rate. Fatigue strength was three-fold higher for WB Mg/Mg and Mg/steel joints than for RSW Mg/steel joints. Fatigue failure in the RSW Mg/steel joints occurred from the heat-affected zone near the notch root at lower load levels, and in the mode of interfacial fracture at higher load levels, while it occurred in the Mg base metal at a maximum cyclic load up to ∼10 kN in

  2. Skilled nursing facilities after joint replacement

    Science.gov (United States)

    ... care providers in the weeks before your joint replacement. They can advise you about whether going directly ... of many people who have had a joint replacement? Can they tell you how many? A good ...

  3. Does Service Interdependence Take Jointness Too Far?

    National Research Council Canada - National Science Library

    Downs, Christopher G

    2008-01-01

    ... integration to support and improve the warfighting effectiveness of joint force commanders. The ability to effectively employ joint forces has increased the lethality, agility, and operational precision of the United States military...

  4. Medical Doctrine - Are We Really Joint

    National Research Council Canada - National Science Library

    Siniscalchi, Kimberly

    1997-01-01

    ... 4.02, Doctrine for Health Service Support in Joint Operations, is analyzed to determine if it provides adequate guidance for seamless health service support in joint operations for war and contingencies other than war...

  5. Theater Logistics Management: A Case for a Joint Distribution Solution

    National Research Council Canada - National Science Library

    Garcia, Jr, Mario V

    2008-01-01

    ...) and Joint Force Commanders (JFC). It explores the factors affecting theater distribution and joint theater logistics management including Joint Reception Staging Onward Movement and Integration (JRSOI) operations...

  6. Semiconducting III-V compounds

    CERN Document Server

    Hilsum, C; Henisch, Heinz R

    1961-01-01

    Semiconducting III-V Compounds deals with the properties of III-V compounds as a family of semiconducting crystals and relates these compounds to the monatomic semiconductors silicon and germanium. Emphasis is placed on physical processes that are peculiar to III-V compounds, particularly those that combine boron, aluminum, gallium, and indium with phosphorus, arsenic, and antimony (for example, indium antimonide, indium arsenide, gallium antimonide, and gallium arsenide).Comprised of eight chapters, this book begins with an assessment of the crystal structure and binding of III-V compounds, f

  7. Jointness for the Rest of Us: Reforming Joint Professional Development

    Science.gov (United States)

    2016-06-10

    requirements. For this reason, improving joint development is not only important for increasing employee job satisfaction , it is essential if DOD...to enhance civilian skill sets and aid in the retention of experienced employees . Further, the report...to the job fully trained. This belief is reinforced by the fact that many mid-and senior-level DOD civilian employees are former members of the armed

  8. Seismic response of rock joints and jointed rock mass

    International Nuclear Information System (INIS)

    Ghosh, A.; Hsiung, S.M.; Chowdhury, A.H.

    1996-06-01

    Long-term stability of emplacement drifts and potential near-field fluid flow resulting from coupled effects are among the concerns for safe disposal of high-level nuclear waste (HLW). A number of factors can induce drift instability or change the near-field flow patterns. Repetitive seismic loads from earthquakes and thermal loads generated by the decay of emplaced waste are two significant factors. One of two key technical uncertainties (KTU) that can potentially pose a high risk of noncompliance with the performance objectives of 10 CFR Part 60 is the prediction of thermal-mechanical (including repetitive seismic load) effects on stability of emplacement drifts and the engineered barrier system. The second KTU of concern is the prediction of thermal-mechanical-hydrological (including repetitive seismic load) effects on the host rock surrounding the engineered barrier system. The Rock Mechanics research project being conducted at the Center for Nuclear Waste Regulatory Analyses (CNWRA) is intended to address certain specific technical issues associated with these two KTUs. This research project has two major components: (i) seismic response of rock joints and a jointed rock mass and (ii) coupled thermal-mechanical-hydrological (TMH) response of a jointed rock mass surrounding the engineered barrier system (EBS). This final report summarizes the research activities concerned with the repetitive seismic load aspect of both these KTUs

  9. Failure Mechanisms of SAC/Fe-Ni Solder Joints During Thermal Cycling

    Science.gov (United States)

    Gao, Li-Yin; Liu, Zhi-Quan; Li, Cai-Fu

    2017-08-01

    Thermal cycling tests have been conducted on Sn-Ag-Cu/Fe- xNi ( x = 73 wt.% or 45 wt.%) and Sn-Ag-Cu/Cu solder joints according to the Joint Electron Device Engineering Council industrial standard to study their interfacial reliability under thermal stress. The interfacial intermetallic compounds formed for solder joints on Cu, Fe-73Ni, and Fe-45Ni were 4.5 μm, 1.7 μm, and 1.4 μm thick, respectively, after 3000 cycles, demonstrating excellent diffusion barrier effect of Fe-Ni under bump metallization (UBM). Also, two deformation modes, viz. solder extrusion and fatigue crack formation, were observed by scanning electron microscopy and three-dimensional x-ray microscopy. Solder extrusion dominated for solder joints on Cu, while fatigue cracks dominated for solder joints on Fe-45Ni and both modes were detected for those on Fe-73Ni. Solder joints on Fe-Ni presented inferior reliability during thermal cycling compared with those on Cu, with characteristic lifetime of 3441 h, 3190 h, and 1247 h for Cu, Fe-73Ni, and Fe-45Ni UBM, respectively. This degradation of the interfacial reliability for solder joints on Fe-Ni is attributed to the mismatch in coefficient of thermal expansion (CTE) at interconnection level. The CTE mismatch at microstructure level was also analyzed by electron backscatter diffraction for clearer identification of recrystallization-related deformation mechanisms.

  10. Dorsoradial capsulodesis for trapeziometacarpal joint instability.

    Science.gov (United States)

    Rayan, Ghazi; Do, Viet

    2013-02-01

    We describe an alternative method for treating chronic trapeziometacarpal (TM) joint instability after acute injury or chronic repetitive use of the thumb by performing a dorsoradial capsulodesis procedure. The procedure is done by imbricating the redundant TM joint dorsoradial ligament and capsule after reducing the joint by pronating the thumb. The dorsoradial capsulodesis is a reasonable reconstructive option for chronic TM joint instability and subluxation. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  11. Sulforaphane Modulates Joint Inflammation in a Murine Model of Complete Freund’s Adjuvant-Induced Mono-Arthritis

    Directory of Open Access Journals (Sweden)

    João Francisco Silva Rodrigues

    2018-04-01

    Full Text Available Rheumatoid arthritis (RA is characterized by inflammation of one or more joints, and affects ~1% of the adult population worldwide. Sulforaphane (SFN is a natural compound that has been suggested as an antioxidant. Here, SFN’s effects were evaluated in a murine mono-arthritis model. Mono-arthritis was induced in mice by a single intra-articular injection of Complete Freund’s Adjuvant (CFA-10 µg/joint, in 10 µL into the ipsilateral joint. The contralateral joint received an equal volume of PBS. On the 4th day post-joint inflammation induction, animals received either SFN (10 mg/kg or vehicle (3% DMSO in saline, intraperitoneally (i.p., twice a day for 3 days. Joint swelling and secondary mechanical allodynia and hyperalgesia were evaluated over 7 days post-CFA. After this period, animals were culled and their blood and synovial fluid samples were collected for analysis of cell populations, cytokine release and thioredoxin reductase (TrxR activity. Knee joint samples were also collected for histology. SFN reduced joint swelling and damage whilst increasing the recruitment of Ly6C+ and Ly6G+ cells to CFA-injected joints. SFN-treated animals presented down-regulation of CD11b and CD62L on synovial fluid Ly6G+ cells. Synovial fluid samples obtained from CFA-injected joints and plasma samples of SFN-treated mice presented higher levels of IL-6 and increased activity of TrxR, in comparison with controls. These results indicate that SFN reduces knee joint damage by modulating cell activation/migration to the joints, cytokine production and increasing the activity of TrxR, and therefore, may represent an alternative treatment to joint inflammation.

  12. Volatile organic compounds

    International Nuclear Information System (INIS)

    Silseth, May Liss

    1998-01-01

    The goal is: Not more emission of volatile organic compounds (VOCs) than necessary. The items discussed in this presentation are the VOCs, how to calculate emission of VOCs, how to reduce or avoid them, and different recovery processes. The largest source of Norwegian emissions of non methane VOCs (NMVOCs) is offshore loading of raw petroleum. Emissions of VOCs should be reduced mainly for two reasons: (1) on sunny days NMVOCs may react with NOx to form ozon and smog close to the surface, (2) ozone and smog close to the surface may be harmful to plants and animals, and they are hazardous to human health. As for the calculation of VOC emissions, the VOCON project will release the calculation program HCGASS in 1999. This project is a cooperative project headed by SINTEF/Marintek

  13. Synthesis of labeled compounds

    International Nuclear Information System (INIS)

    Whaley, T.W.

    1977-01-01

    Intermediate compounds labeled with 13 C included methane, sodium cyanide, methanol, ethanol, and acetonitrile. A new method for synthesizing 15 N-labeled 4-ethylsulfonyl-1-naphthalene-sulfonamide was developed. Studies were conducted on pathways to oleic-1- 13 C acid and a second pathway investigated was based on carbonation of 8-heptadecynylmagnesium bromide with CO 2 to prepare sterolic acid. Biosynthetic preparations included glucose- 13 C from starch isolated from tobacco leaves following photosynthetic incubation with 13 CO 2 and galactose- 13 C from galactosylglycerol- 13 C from kelp. Research on growth of organisms emphasized photosynthetic growth of algae in which all cellular carbon is labeled. Preliminary experiments were performed to optimize the growth of Escherichia coli on sodium acetate- 13 C

  14. Deposition of acidifying compounds

    International Nuclear Information System (INIS)

    Fowler, D.; Cape, J.N.; Sutton, M.A.; Mourne, R.; Hargreaves, K.J.; Duyzer, J.H.; Gallagher, M.W.

    1992-01-01

    Inputs of acidifying compounds to terrestrial ecosystems include deposition of the gases NO 2 , NO, HNO 2 , HNO 3 , NH 3 and SO 2 and the ions NO 3- , NH 4+ , SO 4 2- and H + in precipitation, cloud droplets and particles. Recent research has identified particular ecosystems and regions in which terrestrial effects are closely linked with specific deposition processes. This review paper identifies areas in which important developments have occurred during the last five years and attempts to show which aspects of the subject are most important for policy makers. Amongst the conclusions drawn, the authors advise that current uncertainties in estimates of S and N inputs by dry deposition should be incorporated in critical load calculations, and that, in regions dominated by wet deposition, spatial resolution of total inputs should be improved to match the current scales of information on landscape sensitivity to acidic inputs. 44 refs., 9 figs

  15. 30 CFR 36.24 - Engine joints.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Engine joints. 36.24 Section 36.24 Mineral... Construction and Design Requirements § 36.24 Engine joints. (a) Cylinder head. The joint between the cylinder head and block of the engine shall be fitted with a metal or metal-clad gasket satisfactory to MSHA...

  16. 18 CFR 154.307 - Joint facilities.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Joint facilities. 154... Changes § 154.307 Joint facilities. The Statements required by § 154.312 must show all costs (investment... in the subject rate change and are associated with joint facilities. The methods used in making such...

  17. Acupuncture Therapy on Temporomandibular Joint Syndrome

    Institute of Scientific and Technical Information of China (English)

    XIA Nai-nian; HUANG Ming-juan

    2005-01-01

    @@ Temporomandibular Joint (TMJ) syndrome, an commonly and frequently encountered disease, is characterized by motor dysfunction of mandibular joint and snapping articular surface as major complaints, and then tinnitus, facial pain and occasional headache, most patients got limited mouth open and pain inside the joints or masseter muscle. The authors of this article have treated 68cases of TMJ syndrome since 2001.

  18. Space shuttle SRM field joint: Review paper

    Directory of Open Access Journals (Sweden)

    S. Mohammad Gharouni

    2014-09-01

    Full Text Available Due to Challenger space shuttle accident in 1986, significant research has been done concerning structural behavior of field joints in solid rocket boosters (SRB. The structural deformations between the clevis inner leg and the tang (male-to-female parts of joint, the sealing of the O-ring to prevent the hot gas in joints, has been neglected causing the failure of the vehicle. Redesigning the field joint in SRB engine by accurate analysis of dynamic and thermal loads and by design of insulator and good O-ring, the leakiness of combustion hot gases was eliminated. Some parts of field joint such as capture feature (CF and its third O-ring, J-leg insulator and shim were added to redesigned field joint. Also, some adjustments in sealing system and pins were done to promote the efficiency of the field joint. Due to different experimental analysis on assembled field joints with default imperfections, redesigned joints operated well. These redesigned field joints are commonly used in aerospace and mechanical structures. This paper investigates the original and the redesigned field joints with additional explanations of different parts of the redesigned joints.

  19. Residual load carrying capacity of timber joints

    NARCIS (Netherlands)

    Kuilen, J.W.G. van de

    1999-01-01

    Timber joints that have been preloaded for 2 to 8 years have been short term tested in accordance with EN 26891. The applied load levels varied between 30% and 50% of the average short term strength. The study comprised nailed, toothed-plate and split-ring joints. All joints were made of spruce and

  20. 22 CFR 228.34 - Joint ventures.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Joint ventures. 228.34 Section 228.34 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT RULES ON SOURCE, ORIGIN AND NATIONALITY FOR COMMODITIES AND... Financing § 228.34 Joint ventures. A joint venture or unincorporated association is eligible only if each of...

  1. 47 CFR 76.912 - Joint certification.

    Science.gov (United States)

    2010-10-01

    ... CABLE TELEVISION SERVICE Cable Rate Regulation § 76.912 Joint certification. (a) Franchising authorities..., joint hearings, data collection, and ratemaking. Franchising authorities jointly certified to regulate their cable system(s) may make independent rate decisions. (b) Franchising authorities may apply for...

  2. Russian upstream joint ventures logging progress

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This paper reports that Occidental Petroleum Corp. has begun exporting oil from Russia as part of an enhanced recovery joint venture in western Siberia. Oxy holds a 50% interest in the joint venture company, Vanyoganneft, and will market the oil. In other activity, two Canadian companies are marking progress with Russian upstream joint ventures

  3. Molecular monitoring of equine joint homeostasis

    NARCIS (Netherlands)

    de Grauw, J.C.

    2010-01-01

    Chronic joint disorders are a major cause of impaired mobility and loss of quality of life in both humans and horses. Regardless of the primary insult, any joint disorder is characterized by an upset in normal joint homeostasis, the balance between tissue anabolism and catabolism that is normally

  4. Estimation of Joint types and Joint Limits from Motion capture data

    DEFF Research Database (Denmark)

    Engell-Nørregård, Morten Pol; Erleben, Kenny

    2009-01-01

    It is time-consuming for an animator to explicitly model joint types and joint limits of articulated figures. In this paper we describe a simple and fast approach to automated joint estimation from motion capture data of articulated figures. Our method will make the joint modeling more efficient ...

  5. Joint Chiefs of Staff > About > The Joint Staff > Senior Enlisted Advisor

    Science.gov (United States)

    Skip to main content (Press Enter). Toggle navigation Joint Chiefs of Staff Joint Chiefs of Staff Joint Chiefs of Staff Facebook Twitter YouTube Flickr Blog Instagram Search JCS: Search Search Search JCS: Search Home Media News Photos Videos Publications About The Joint Staff Chairman Vice Chairman

  6. Wilmar joint market model, Documentation

    International Nuclear Information System (INIS)

    Meibom, P.; Larsen, Helge V.; Barth, R.; Brand, H.; Weber, C.; Voll, O.

    2006-01-01

    The Wilmar Planning Tool is developed in the project Wind Power Integration in Liberalised Electricity Markets (WILMAR) supported by EU (Contract No. ENK5-CT-2002-00663). A User Shell implemented in an Excel workbook controls the Wilmar Planning Tool. All data are contained in Access databases that communicate with various sub-models through text files that are exported from or imported to the databases. The Joint Market Model (JMM) constitutes one of these sub-models. This report documents the Joint Market model (JMM). The documentation describes: 1. The file structure of the JMM. 2. The sets, parameters and variables in the JMM. 3. The equations in the JMM. 4. The looping structure in the JMM. (au)

  7. Bony ankylosis of temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byeong Do; Yoon, Young Nam; Um, Ki Doo; Ra, Jong Ill; Lee, Wan [School of Dentistry, Wonkwang University, Iksan (Korea, Republic of)

    2002-06-15

    Ankylosis of joint is defined as limited movement due to infection, trauma, or surgical procedure. A 59-year-old female with a chief complaint of limited movements during mouth opening had a positive history of trauma to her right TMJ area about 5 years ago. From that time, progressive mouth opening limitation and intermittent pain have occurred. At the time of admission the patient showed mandibular deviation to the right side during mouth opening, with a maximum opening limited to 5 mm. On plain radiographs, right condylar enlargement and joint space reduction by newly formed bony tissues were observed. CT scans showed right condylar enlargement, cortical sclerosis, and thickening of the condyle, articular fossa and articular eminence.

  8. Grasp cueing and joint attention.

    Science.gov (United States)

    Tschentscher, Nadja; Fischer, Martin H

    2008-10-01

    We studied how two different hand posture cues affect joint attention in normal observers. Visual targets appeared over lateralized objects, with different delays after centrally presented hand postures. Attention was cued by either hand direction or the congruency between hand aperture and object size. Participants pressed a button when they detected a target. Direction cues alone facilitated target detection following short delays but aperture cues alone were ineffective. In contrast, when hand postures combined direction and aperture cues, aperture congruency effects without directional congruency effects emerged and persisted, but only for power grips. These results suggest that parallel parameter specification makes joint attention mechanisms exquisitely sensitive to the timing and content of contextual cues.

  9. Joint hypermobility syndrome in rheumatology

    Directory of Open Access Journals (Sweden)

    A. M. Satybaldyev

    2017-01-01

    Full Text Available Joint hypermobility syndrome (JHS is a disease characterized by symptoms of locomotor system involvement in the absence of obvious systemic rheumatic diseases (RDs. JHS accompanied by the symptomatology of RDs should be distinguished from isolated joint hypermobility, in which there are no complaints even in cases of its generalized manifestations and the patients feel virtually healthy. The paper provides an overview of the literature on the JHS. It gives diagnostic criteria for JHS (the Brighton criteria encompasses the Beighton score and the clinical manifestation of damages to the locomotor apparatus, visceral organs, and skin in this syndrome. Autonomic nervous system dysfunction as a possible manifestation of JHS and its impact on the daily life of patients are discussed. Attention is paid to the prevention and treatment of JHS. 

  10. Hydrocolonotherapy ankle joints after injuries

    Directory of Open Access Journals (Sweden)

    Volodymyr Muchin

    2016-02-01

    Full Text Available Purpose: to improve efficiency of gydrokinesitherapy by means of specially designed devices and monolasts for patients after ankle joint injuries. Material & Methods: there are pedagogical methods, clinical and radiological methods, anthropometric measurements and goniometry were used. Results: the author's technique of hydrokinesitherapy with application hydrokinesimechanotherapy device in the program of physical rehabilitation which provides optimum conditions for the recovery process was developed. Conclusions: the specially designed hydrokinesomechanotherapeutic device and monolasts are allow strictly controlled movement in all planes of the ankle joint, which contributes to the acceleration of the recovery; the conducted anthropometric and goniometric studies were indicate more rapid elimination of edema, increase movement amplitude, carries opposition to the development of contractures and muscle atrophy.

  11. Wilmar joint market model, Documentation

    Energy Technology Data Exchange (ETDEWEB)

    Meibom, P.; Larsen, Helge V. [Risoe National Lab. (Denmark); Barth, R.; Brand, H. [IER, Univ. of Stuttgart (Germany); Weber, C.; Voll, O. [Univ. of Duisburg-Essen (Germany)

    2006-01-15

    The Wilmar Planning Tool is developed in the project Wind Power Integration in Liberalised Electricity Markets (WILMAR) supported by EU (Contract No. ENK5-CT-2002-00663). A User Shell implemented in an Excel workbook controls the Wilmar Planning Tool. All data are contained in Access databases that communicate with various sub-models through text files that are exported from or imported to the databases. The Joint Market Model (JMM) constitutes one of these sub-models. This report documents the Joint Market model (JMM). The documentation describes: 1. The file structure of the JMM. 2. The sets, parameters and variables in the JMM. 3. The equations in the JMM. 4. The looping structure in the JMM. (au)

  12. Metal-ceramic joint assembly

    Science.gov (United States)

    Li, Jian

    2002-01-01

    A metal-ceramic joint assembly in which a brazing alloy is situated between metallic and ceramic members. The metallic member is either an aluminum-containing stainless steel, a high chromium-content ferritic stainless steel or an iron nickel alloy with a corrosion protection coating. The brazing alloy, in turn, is either an Au-based or Ni-based alloy with a brazing temperature in the range of 9500 to 1200.degree. C.

  13. Arthrography of the ankle joint

    International Nuclear Information System (INIS)

    Crespi Porro, R.; Zellner, A.; Puricelli, G.; Quaglia, R.; Chelazzi, G.

    1984-01-01

    Arthrography of the ankle joint was first carried out by Johnson and Palmer at the Military Hospital in Stockholm in 1940. Arthrography can be used for judging the integrity of the articular cartilage, of osteochondritis dissecans, arthritis or adhesive capsulitis. The literature shows, however, that more than 95% of the patients on whom this examination has been performed has suffered from acute trauma. (orig.) [de

  14. On joint numerical radius II

    Czech Academy of Sciences Publication Activity Database

    Drnovšek, R.; Müller, Vladimír

    2014-01-01

    Roč. 62, č. 9 (2014), s. 1197-1204 ISSN 0308-1087 R&D Projects: GA ČR GA201/09/0473; GA AV ČR IAA100190903 Institutional support: RVO:67985840 Keywords : joint numerical range * numerical radius Subject RIV: BA - General Mathematics Impact factor: 0.738, year: 2014 http://www.tandfonline.com/doi/abs/10.1080/03081087.2013.816303

  15. Space Suit Joint Torque Testing

    Science.gov (United States)

    Valish, Dana J.

    2011-01-01

    In 2009 and early 2010, a test was performed to quantify the torque required to manipulate joints in several existing operational and prototype space suits in an effort to develop joint torque requirements appropriate for a new Constellation Program space suit system. The same test method was levied on the Constellation space suit contractors to verify that their suit design meets the requirements. However, because the original test was set up and conducted by a single test operator there was some question as to whether this method was repeatable enough to be considered a standard verification method for Constellation or other future space suits. In order to validate the method itself, a representative subset of the previous test was repeated, using the same information that would be available to space suit contractors, but set up and conducted by someone not familiar with the previous test. The resultant data was compared using graphical and statistical analysis and a variance in torque values for some of the tested joints was apparent. Potential variables that could have affected the data were identified and re-testing was conducted in an attempt to eliminate these variables. The results of the retest will be used to determine if further testing and modification is necessary before the method can be validated.

  16. [Sports participation after joint arthroplasty].

    Science.gov (United States)

    Dauty, M; Letenneur, J

    2007-12-01

    To recommand sports activities after joint arthroplasty from the literature analysis, the French surgeon's opinion and wish patients. From the Medline data base interrogation according to keywords: Sports, Arthroplasty, Athletics, Physical training, two different readers, an orthopedic surgeon and a Physical Medicine and Rehabilitation physician selected articles in French or English language according to the level of proofs of the french classification of the Accreditation and Health Evaluation National Agency (Anaes). Professional practices were estimated by the interrogation of 30 orthopedic surgeons members of the french West Orthopaedics Society (SOO). The demand of sports practice was studied with patients recently operated for a primary total knee arthroplasty (TKA) after gonarthrosis. Twenty-two articles were selected from 305 articles obtained by the search according to keywords. Ten literature reviews are limited by the absence of prospective randomized study. A level II study and eleven level IV articles are reported. According to the subjective orthropedic surgeon's opinion, the objective results based on the joint load studied and the percentage of arthroplasty revision, sport is beneficial for the individual health but perhaps not for the arthroplasty survey. However, aerobic and leisure activities are recommended (walking, swimming, cycling) in agreement with the demand of the patients recently operated with a TKA. TKA differs from Total Hip Arthroplasty for jogging because of knee joint constraints during the knee flexion. A single study reports sports possibilities after shoulder arthroplasty and ankle arthroplasty and no study reports results after elbow arthroplasty.

  17. [Joint contractures in nursing textbooks].

    Science.gov (United States)

    Bartoszek, G; Meyer, G; Thiesemann, R

    2014-01-01

    The transparency criteria of the German statutory health insurance on joint contracture prevention have led to controversies about the appropriate assessment, prevention and treatment as well as to various actions in nursing practice. However, appropriate nursing assessments and proven treatment options are lacking so far. It is unclear whether textbooks on nursing reflect these uncertainties. Search for textbooks on nursing through internet-based search engines and publisher registers, data extraction by one investigator and control by a second. A total of 35 textbooks with contributions on joint contractures were identified of which 25 included a definition, causes/risk factors are presented in 32 textbooks and assessments are presented in 5 books. Most often positioning into a physiological or functional neutral position and passive moving of limbs are recommended as passive prophylaxis. Recommended therapeutic and preventive options do not differ. None of the textbooks reflect that there is a lack of scientific knowledge on the subject. Textbooks on nursing do not deal with complete and scientific sound information on joint contractures.

  18. Mechanical flexible joint design document

    Science.gov (United States)

    Daily, Vic

    1993-01-01

    The purpose of this report is to document the status of the Mechanical Flexible Joint (MFJ) Design Subtask with the intent of halting work on the design. Recommendations for future work is included in the case that the task is to be resumed. The MFJ is designed to eliminate two failure points from the current flex joint configuration, the inner 'tripod configuration' and the outer containment jacket. The MFJ will also be designed to flex 13.5 degrees and have three degrees of freedom. By having three degrees of freedom, the MFJ will allow the Low Pressure Fuel Duct to twist and remove the necessity to angulate the full 11 degrees currently required. The current flex joints are very labor intensive and very costly and a simple alternative is being sought. The MFJ is designed with a greater angular displacement, with three degrees of freedom, to reside in the same overall envelope, to meet weight constraints of the current bellows, to be compatible with cryogenic fuel and oxidizers, and also to be man-rated.

  19. Synergy Maps: exploring compound combinations using network-based visualization.

    Science.gov (United States)

    Lewis, Richard; Guha, Rajarshi; Korcsmaros, Tamás; Bender, Andreas

    2015-01-01

    The phenomenon of super-additivity of biological response to compounds applied jointly, termed synergy, has the potential to provide many therapeutic benefits. Therefore, high throughput screening of compound combinations has recently received a great deal of attention. Large compound libraries and the feasibility of all-pairs screening can easily generate large, information-rich datasets. Previously, these datasets have been visualized using either a heat-map or a network approach-however these visualizations only partially represent the information encoded in the dataset. A new visualization technique for pairwise combination screening data, termed "Synergy Maps", is presented. In a Synergy Map, information about the synergistic interactions of compounds is integrated with information about their properties (chemical structure, physicochemical properties, bioactivity profiles) to produce a single visualization. As a result the relationships between compound and combination properties may be investigated simultaneously, and thus may afford insight into the synergy observed in the screen. An interactive web app implementation, available at http://richlewis42.github.io/synergy-maps, has been developed for public use, which may find use in navigating and filtering larger scale combination datasets. This tool is applied to a recent all-pairs dataset of anti-malarials, tested against Plasmodium falciparum, and a preliminary analysis is given as an example, illustrating the disproportionate synergism of histone deacetylase inhibitors previously described in literature, as well as suggesting new hypotheses for future investigation. Synergy Maps improve the state of the art in compound combination visualization, by simultaneously representing individual compound properties and their interactions. The web-based tool allows straightforward exploration of combination data, and easier identification of correlations between compound properties and interactions.

  20. BIOMECHANICS AND PATHOMECHANICS OF THE PATELLOFEMORAL JOINT

    Science.gov (United States)

    2016-01-01

    The patellofemoral joint is a joint that can be an area of concern for athletes of various sports and ages. The joint is somewhat complex with multiple contact points and numerous tissues that attach to the patella. Joint forces are variable and depend on the degree of knee flexion and whether the foot is in contact with the ground. The sports medicine specialist must have a good working knowledge of the anatomy and biomechanics of the patellofemoral joint in order to treat it effectively. PMID:27904787

  1. Analysis of NSTX TF Joint Voltage Measurements

    International Nuclear Information System (INIS)

    Woolley R

    2005-01-01

    This report presents findings of analyses of recorded current and voltage data associated with 72 electrical joints operating at high current and high mechanical stress. The analysis goal was to characterize the mechanical behavior of each joint and thus evaluate its mechanical supports. The joints are part of the toroidal field (TF) magnet system of the National Spherical Torus Experiment (NSTX) pulsed plasma device operating at the Princeton Plasma Physics Laboratory (PPPL). Since there is not sufficient space near the joints for much traditional mechanical instrumentation, small voltage probes were installed on each joint and their voltage monitoring waveforms have been recorded on sampling digitizers during each NSTX ''shot''

  2. TSTA compound cryopump

    International Nuclear Information System (INIS)

    Batzer, T.H.; Patrick, R.E.; Call, W.R.

    1980-01-01

    The Tritium System Test Assembly (TSTA), at the Los Alamos Scientific Laboratory, is intended to demonstrate realistic fuel supply and cleanup scenarios for future fusion reactors. The vacuum pumps must be capable of handling large quantities of reactor exhaust gases consisting largely of mixtures of hydrogen and helium isotopes. Cryocondensing pumps will not pump helium at 4.2 K; while cryosorption pumps using molecular sieves or charcoal have good helium pumping speed, the adsorbent clogs with condensed hydrogen while pumping mixtures of both. A solution to this problem is a compound design whereby the first stage condenses the hydrogen and the second, or sorption, stage pumps the helium. The TSTA pump designed at Lawrence Livermore National Laboratory uses argon gas to cryotrap the helium in the helium-hydrogen mixture. The argon is sprayed directly onto the 4.2 K surface at a rate proportional to the helium flow rate, permitting continuous pumping of the helium-hydrogen mixtures in a single-stage pump. However, the possibility of differential desorption as a first stage in the TSTA gas separation cycle required the inclusion of a first-stage hydrogen isotope condenser. The design, performance, and operating characteristics are discussed

  3. Pluto's Nonvolatile Chemical Compounds

    Science.gov (United States)

    Grundy, William M.; Binzel, Richard; Cook, Jason C.; Cruikshank, Dale P.; Dalle Ore, Cristina M.; Earle, Alissa M.; Ennico, Kimberly; Jennings, Donald; Howett, Carly; Kaiser, Ralf-Ingo; Linscott, Ivan; Lunsford, A. W.; Olkin, Catherine B.; Parker, Alex Harrison; Parker, Joel Wm.; Philippe, Sylvain; Protopapa, Silvia; Quirico, Eric; Reuter, D. C.; Schmitt, Bernard; Singer, Kelsi N.; Spencer, John R.; Stansberry, John A.; Stern, S. Alan; Tsang, Constantine; Verbiscer, Anne J.; Weaver, Harold A.; Weigle, G. E.; Young, Leslie

    2016-10-01

    Despite the migration of Pluto's volatile ices (N2, CO, and CH4) around the surface on seasonal timescales, the planet's non-volatile materials are not completely hidden from view. They occur in a variety of provinces formed over a wide range of timescales, including rugged mountains and chasms, the floors of mid-latitude craters, and an equatorial belt of especially dark and reddish material typified by the informally named Cthulhu Regio. NASA's New Horizons probe observed several of these regions at spatial resolutions as fine as 3 km/pixel with its LEISA imaging spectrometer, covering wavelengths from 1.25 to 2.5 microns. Various compounds that are much lighter than the tholin-like macromolecules responsible for the reddish coloration, but that are not volatile at Pluto surface temperatures such as methanol (CH3OH) and ethane (C2H6) have characteristic absorption bands within LEISA's wavelength range. This presentation will describe their geographic distributions and attempt to constrain their origins. Possibilities include an inheritance from Pluto's primordial composition (the likely source of H2O ice seen on Pluto's surface) or ongoing production from volatile precursors through photochemistry in Pluto's atmosphere or through radiolysis on Pluto's surface. New laboratory data inform the analysis.This work was supported by NASA's New Horizons project.

  4. Affixation and compounding in Hakka

    OpenAIRE

    Ungsitipoonporn, Siriopen

    2014-01-01

    This paper aims to present the internal structures of words in the Hakka language. Similar to other languages, affixation and compounding are outstanding in Hakka. In general, prefixes and suffixes are bound morphemes which do not occur independently, but in Hakka they sometimes appear as independent forms. Apart from single words, identifying compound words is of particular interest. Compound nouns can be made up of two or three words (characters) which ...

  5. Joint Center Estimation Using Single-Frame Optimization: Part 1: Numerical Simulation.

    Science.gov (United States)

    Frick, Eric; Rahmatalla, Salam

    2018-04-04

    The biomechanical models used to refine and stabilize motion capture processes are almost invariably driven by joint center estimates, and any errors in joint center calculation carry over and can be compounded when calculating joint kinematics. Unfortunately, accurate determination of joint centers is a complex task, primarily due to measurements being contaminated by soft-tissue artifact (STA). This paper proposes a novel approach to joint center estimation implemented via sequential application of single-frame optimization (SFO). First, the method minimizes the variance of individual time frames’ joint center estimations via the developed variance minimization method to obtain accurate overall initial conditions. These initial conditions are used to stabilize an optimization-based linearization of human motion that determines a time-varying joint center estimation. In this manner, the complex and nonlinear behavior of human motion contaminated by STA can be captured as a continuous series of unique rigid-body realizations without requiring a complex analytical model to describe the behavior of STA. This article intends to offer proof of concept, and the presented method must be further developed before it can be reasonably applied to human motion. Numerical simulations were introduced to verify and substantiate the efficacy of the proposed methodology. When directly compared with a state-of-the-art inertial method, SFO reduced the error due to soft-tissue artifact in all cases by more than 45%. Instead of producing a single vector value to describe the joint center location during a motion capture trial as existing methods often do, the proposed method produced time-varying solutions that were highly correlated ( r > 0.82) with the true, time-varying joint center solution.

  6. Joint Center Estimation Using Single-Frame Optimization: Part 1: Numerical Simulation

    Directory of Open Access Journals (Sweden)

    Eric Frick

    2018-04-01

    Full Text Available The biomechanical models used to refine and stabilize motion capture processes are almost invariably driven by joint center estimates, and any errors in joint center calculation carry over and can be compounded when calculating joint kinematics. Unfortunately, accurate determination of joint centers is a complex task, primarily due to measurements being contaminated by soft-tissue artifact (STA. This paper proposes a novel approach to joint center estimation implemented via sequential application of single-frame optimization (SFO. First, the method minimizes the variance of individual time frames’ joint center estimations via the developed variance minimization method to obtain accurate overall initial conditions. These initial conditions are used to stabilize an optimization-based linearization of human motion that determines a time-varying joint center estimation. In this manner, the complex and nonlinear behavior of human motion contaminated by STA can be captured as a continuous series of unique rigid-body realizations without requiring a complex analytical model to describe the behavior of STA. This article intends to offer proof of concept, and the presented method must be further developed before it can be reasonably applied to human motion. Numerical simulations were introduced to verify and substantiate the efficacy of the proposed methodology. When directly compared with a state-of-the-art inertial method, SFO reduced the error due to soft-tissue artifact in all cases by more than 45%. Instead of producing a single vector value to describe the joint center location during a motion capture trial as existing methods often do, the proposed method produced time-varying solutions that were highly correlated (r > 0.82 with the true, time-varying joint center solution.

  7. Natural compounds with herbicidal activity

    Directory of Open Access Journals (Sweden)

    Mariano Fracchiolla

    2007-12-01

    Full Text Available Research about phytotoxic activity of natural compounds could lead both to find new herbicidal active ingredients and to plan environmental friendly weed control strategies. Particularly, living organisms could be a source of compounds that are impossible, for their complexity, to synthesize artificially. More over, they could have alternative sites of action respect to the known chemical herbicides and, due to their origin, they should be more environmental safe. Many living organism, such as bacteria, fungi, insects, lichens and plants, are able to produce bioactive compounds. They generally are secondary metabolites or simply waste molecules. In this paper we make a review about these compounds, highlighting potential and constraints.

  8. Natural compounds with herbicidal activity

    Directory of Open Access Journals (Sweden)

    Pasquale Montemurro

    2011-02-01

    Full Text Available Research about phytotoxic activity of natural compounds could lead both to find new herbicidal active ingredients and to plan environmental friendly weed control strategies. Particularly, living organisms could be a source of compounds that are impossible, for their complexity, to synthesize artificially. More over, they could have alternative sites of action respect to the known chemical herbicides and, due to their origin, they should be more environmental safe. Many living organism, such as bacteria, fungi, insects, lichens and plants, are able to produce bioactive compounds. They generally are secondary metabolites or simply waste molecules. In this paper we make a review about these compounds, highlighting potential and constraints.

  9. Joint Chiefs of Staff > Directorates > J6 | C4 & Cyber

    Science.gov (United States)

    Joint Staff Structure Joint Staff Inspector General Origin of Joint Concepts U.S. Code | Joint Chiefs of Management J1 | Manpower and Personnel J2 | Joint Staff Intelligence J3 | Operations J4 | Logistics► the Joint Staff Chief Information Officer (CIO), the J-6 provides business class Information

  10. X-ray and radionuclide investigations of the bones and joints in psoriasis

    International Nuclear Information System (INIS)

    Spuzyak, M.I.; Vasil'ev, A.A.; Belyaev, G.M.; Vikman, Ya.Eh.

    1990-01-01

    Radiography of the bones and joints was performed in 133 psoriatic patients; osteoscintigraphy with 99m Tc-phosphate compounds was also performed in 42 of them. On the basis of x-ray findings 3 types of osteoarticular psoriasis were singled out: psoriatic polyarthritis, psoriatic polyarthrosis and psoriatic arthropathy. The most ample information on the type, activity and spreading of a pathological process in the bones and joints in psoriasis can be obtained from the combination of the x-ray and radionuclide methods

  11. Part I. Remembering No. 2 (Ladislav Loerinc). EMO joint venture, joint-stock company - really completely useless organ?

    International Nuclear Information System (INIS)

    Blaha, M.

    2008-01-01

    In this chapter author reviewed the story of the EMO joint venture, joint-stock company, between Slovenske elektrarne, a. s. and EdF. EMO joint venture, joint-stock company, was established to complete the Mochovce nuclear power plant. EMO joint venture, joint-stock company was closed after one year of work. History of EMO joint venture, joint-stock company, was described by its former general manager Mr. Ladislav Loerinc.

  12. Antimicrobial compounds in tears.

    Science.gov (United States)

    McDermott, Alison M

    2013-12-01

    The tear film coats the cornea and conjunctiva and serves several important functions. It provides lubrication, prevents drying of the ocular surface epithelia, helps provide a smooth surface for refracting light, supplies oxygen and is an important component of the innate defense system of the eye providing protection against a range of potential pathogens. This review describes both classic antimicrobial compounds found in tears such as lysozyme and some more recently identified such as members of the cationic antimicrobial peptide family and surfactant protein-D as well as potential new candidate molecules that may contribute to antimicrobial protection. As is readily evident from the literature review herein, tears, like all mucosal fluids, contain a plethora of molecules with known antimicrobial effects. That all of these are active in vivo is debatable as many are present in low concentrations, may be influenced by other tear components such as the ionic environment, and antimicrobial action may be only one of several activities ascribed to the molecule. However, there are many studies showing synergistic/additive interactions between several of the tear antimicrobials and it is highly likely that cooperativity between molecules is the primary way tears are able to afford significant antimicrobial protection to the ocular surface in vivo. In addition to effects on pathogen growth and survival some tear components prevent epithelial cell invasion and promote the epithelial expression of innate defense molecules. Given the protective role of tears a number of scenarios can be envisaged that may affect the amount and/or activity of tear antimicrobials and hence compromise tear immunity. Two such situations, dry eye disease and contact lens wear, are discussed here. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Effect of Solder-Joint Geometry on the Low-Cycle Fatigue Behavior of Sn- xAg-0.7Cu

    Science.gov (United States)

    Lee, Hwa-Teng; Huang, Kuo-Chen

    2016-12-01

    Low-cycle fatigue tests of Sn-Ag-Cu (SAC) Pb-free solder joints under fixed displacement were performed to evaluate the influence of Ag content (0-3 wt.%) and solder-joint geometry (barrel and hourglass types) on solder-joint fatigue behavior and reliability. The solder joints were composed of fine particles of Ag3Sn and Cu6Sn5, which aggregated as an eutectic constituent at grain boundaries of the primary β-Sn phase and formed a dense network structure. A decrease in the Ag content resulted in coarsening of the β-Sn and eutectic phases, which, in turn, decreased the strength of the joint and caused earlier failure. Solder joints in the hourglass form exhibited better fatigue performance with longer life than barrel-type joints. The sharp contact angle formed between the solder and the Cu substrate by the barrel-type joints concentrated stress, which compromised fatigue reliability. The addition of Ag to the solder, however, enhanced fatigue performance because of strengthening caused by Ag3Sn formation. The cracks of the barrel-type SAC solder joints originated mostly at the contact corner and propagated along the interfacial layer between the interfacial intermetallic compound (IMC) and solder matrix. Hourglass-type solder joints, however, demonstrated both crack initiation and propagation in the solder matrix (solder mode). The addition of 1.5-2.0 wt.% Ag to SAC solder appears to enhance the fatigue performance of solder joints while maintaining sufficient strength.

  14. Periprosthetic joint infection: are patients with multiple prosthetic joints at risk?

    Science.gov (United States)

    Jafari, S Mehdi; Casper, David S; Restrepo, Camilo; Zmistowski, Benjamin; Parvizi, Javad; Sharkey, Peter F

    2012-06-01

    Patients who present with a periprosthetic joint infection in a single joint may have multiple prosthetic joints. The risk of these patients developing a subsequent infection in another prosthetic joint is unknown. Our purposes were (1) to identify the risk of developing a subsequent infection in another prosthetic joint and (2) to describe the time span and organism profile to the second prosthetic infection. We retrospectively identified 55 patients with periprosthetic joint infection who had another prosthetic joint in place at the time of presentation. Of the 55 patients, 11 (20%) developed a periprosthetic joint infection in a second joint. The type of organism was the same as the first infection in 4 (36%) of 11 patients. The time to developing a second infection averaged 2.0 years (range, 0-6.9 years). Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Water flow in single rock joints

    International Nuclear Information System (INIS)

    Hakami, Eva

    1989-05-01

    To study the hydromechanical properties of single rock joints a technique to make transparent replicas of natural joint surfaces has been developed. Five different joint samples were replicated and studied. The aperture distribution of the joints were obtained through a measurement method provided by the transparent replicas. The principle behind the method is that a water drop with a known volume, which is placed inside a joint, will cover a certain area of the surface depending on the average size of aperture at the actual point. Flow tests were performed on the same joint replicas. The tortuousity of the flow and the velocity along single stream lines were measured using colour injections into the water flow through the joints. The equivalent hydraulic apertures determined from the flow tests where shown to be smaller than the average mechanical apertures. The velocity of the flow varies strongly between different paths over the joint depending on the spatial distribution of the apertures. The degree of matedness between the joint surfaces is an important factor influencing the channeling character of the joints. (author) (38 refs.)

  16. The volume of the human knee joint.

    Science.gov (United States)

    Matziolis, Georg; Roehner, Eric; Windisch, Christoph; Wagner, Andreas

    2015-10-01

    Despite its clinical relevance, particularly in septic knee surgery, the volume of the human knee joint has not been established to date. Therefore, the objective of this study was to determine knee joint volume and whether or not it is dependent on sex or body height. Sixty-one consecutive patients (joints) who were due to undergo endoprosthetic joint replacement were enrolled in this prospective study. During the operation, the joint volume was determined by injecting saline solution until a pressure of 200 mmHg was achieved in the joint. The average volume of all knee joints was 131 ± 53 (40-290) ml. The volume was not found to be dependent on sex, but it was dependent on the patients' height (R = 0.312, p = 0.014). This enabled an estimation of the joint volume according to V = 1.6 height - 135. The considerable inter-individual variance of the knee joint volume would suggest that it should be determined or at least estimated according to body height if the joint volume has consequences for the diagnostics or therapy of knee disorders.

  17. Hyperextension of the elbow joint

    DEFF Research Database (Denmark)

    Tyrdal, Stein; Olsen, Bo Sanderhoff

    1998-01-01

    According to an epidemiologic study (Scand J Med Sci 1996/ 6: 297-302) the mechanism of "handball goalie's elbow" may be forced hyperextension. The pathomechanics of hyperextension were studied in nine macroscopically normal male cadaver elbow joints. The mean age of the donors was 43.2 years...... of the medial collateral ligament; (3) occasional incomplete rupture of the lateral collateral ligament; and (4) small fragments of cartilage near the posterior edge of the ulna in one of the specimens. One or more of these lesions may be responsible for the symptoms in "handball goalie's elbow."...

  18. Joint implementation along two ways

    International Nuclear Information System (INIS)

    De Vos, R.

    1997-01-01

    In the test phase to the year 2000 joint implementation (JI) must prove to be a valuable tool for the climate change policy. The Dutch Ministries of Housing, Planning and Environmental Protection (VROM) and Economic Affairs (EZ) would like to form a basis for a JI-protocol during the Climate Conference in Kyoto, Japan, which will be held at the end of 1997. However, the Ministry of Development Cooperation wants to follow a more careful approach towards the cooperation with developing countries. Special attention is paid to a JI-project in Romania

  19. Automatic locking knee brace joint

    Science.gov (United States)

    Weddendorf, Bruce (Inventor)

    1995-01-01

    This invention is an apparatus for controlling the pivotal movement of a knee brace comprising a tang-and-clevis joint that has been uniquely modified. Both the tang and the clevis have a set of teeth that, when engaged, can lock the tang and the clevis together. In addition, the tang is biased away from the clevis. Consequently, when there is no axial force (i.e., body weight) on the tang, the tang is free to pivot within the clevis. However, when an axial force is exerted on the tang, the tang is pushed into the clevis, both sets of teeth engage, and the tang and the clevis lock together.

  20. Joint studies on large CANDU

    International Nuclear Information System (INIS)

    Lee, Ikhwan; Yu, S. K. W.

    1994-01-01

    CANDU PHWRs have demonstrated generic benefits which will be continued in future designs. These include economic benefits due to low operating costs, business potential, strategic benefits due to fuel cycle flexibility and operational benefits. These benefits have been realized in Korea through the operation of Wolsong 1, resulting in further construction of PHWRs at the same site. The principal benefit, low electricity cost, is due to the high capacity factor and the low fuel cost for CANDU. The CANDU plant at Wolsong has proven to be a safe, reliable and economical electricity producer. The ability of PHWR to burn natural uranium ensures security of fuel supply. Following successful Technology Transfer via the Wolsong 2,3 and 4 project, future opportunity exists between Korea and Canada for continuing co-operation in research and development to improve the technology base, for product development partnerships, and business opportunities in marketing and building PHWR plants in third countries. High reliability, through excellent design, well-controlled operation, efficient maintenance and low operating costs is critical to the economic viability of nuclear plants. CANDU plants have an excellent performance record. The four operating CANDU 6 plants, operated by four utilities in three countries, are world performance leaders. The CANDU 9 design, with higher output capacity, will help to achieve better site utilization and lower electricity costs. Being an evolutionary design, CANDU 9 assures high performance by utilizing proven systems, and component designs adapted from operating CANDU plants (Bruce B, Darlington and CANDU 6). All system and operating parameters are within the operating proven range of current plants. KAERI and AECL have an agreement to perform joint studies on future PHWR development. The objective of the joint studies is to establish the requirements for the design of future advanced CANDU PHWR including the utility need for design improvements

  1. The joint implementation mechanisms (MOC)

    International Nuclear Information System (INIS)

    2003-01-01

    The aim of the joint implementation mechanisms (MOC) is aims to favor the fight against the climatic change, by the implementing of activities, technologies and appropriate techniques emitting less greenhouse gases in south countries and by the possibility of reducing the greenhouse gases emissions for a more economical cost. This guide brings a practical assistance to the projects set-up: the possible concerned projects, the formalization of the project, the methodology, the involvement of the carbon credits in the project financing. (A.L.B.)

  2. Jet Joint Undertaking. Vol. 2

    International Nuclear Information System (INIS)

    1989-06-01

    The scientific, technical, experimental and theoretical investigations related to JET tokamak are presented. The JET Joint Undertaking, Volume 2, includes papers presented at: the 15th European Conference on controlled fusion and plasma heating, the 15th Symposium on fusion technology, the 12th IAEA Conference on plasma physics and controlled nuclear fusion research, the 8th Topical Meeting on technology of fusion. Moreover, the following topics, concerning JET, are discussed: experience with wall materials, plasma performance, high power ion cyclotron resonance heating, plasma boundary, results and prospects for fusion, preparation for D-T operation, active gas handling system and remote handling equipment

  3. II-VI semiconductor compounds

    CERN Document Server

    1993-01-01

    For condensed matter physicists and electronic engineers, this volume deals with aspects of II-VI semiconductor compounds. Areas covered include devices and applications of II-VI compounds; Co-based II-IV semi-magnetic semiconductors; and electronic structure of strained II-VI superlattices.

  4. Compound-heterozygous Marfan syndrome

    NARCIS (Netherlands)

    van Dijk, F. S.; Hamel, B. C.; Hilhorst-Hofstee, Y.; Mulder, B. J. M.; Timmermans, J.; Pals, G.; Cobben, J. M.

    2009-01-01

    We report two families in which the probands have compound-heterozygous Marfan syndrome (MFS). The proband of family I has the R2726W FBN1 mutation associated with isolated skeletal features on one allele and a pathogenic FBN1 mutation on the other allele. The phenotype of the compound-heterozygous

  5. Radioactive decay and labeled compounds

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    This chapter on radioactive decay and labeled compounds has numerous intext equations and worked, sample problems. Topics covered include the following: terms and mathematics of radioactive decay; examples of calculations; graphs of decay equations; radioactivity or activity; activity measurements; activity decay; half-life determinations; labeled compounds. A 20 problem set is also included. 1 ref., 4 figs., 1 tab

  6. Radiolysis of other organic compounds

    International Nuclear Information System (INIS)

    Pikaev, A.K.

    1986-01-01

    Peculiarities of radiolysis of organic halogen, phosphorus, sulfur and nitrogen (including amines, amides, nitriles et al.) compounds in liquid phase are discussed. Intermediate and stable finish products of radiolysis of the given compounds, properties and radiochemical yields of these products are considered

  7. 2. Intermetallic compounds with lanthanides

    International Nuclear Information System (INIS)

    Elemans, J.B.A.A.

    1975-01-01

    Theoretical considerations are given concerning the structures of intermetallic compounds of the lanthanides and thorium (R) on the one hand, and with Fe, Co or Ni (M) on the other. They all derive from the parent composition RM 5 with the CaCu 5 hexagonal structure. This consists of alternate layers in which the M atoms are distinguished as M 1 and M 2 . The other compounds whose structures are studied are obtained by systematic replacement of R by M, or vice versa. In the first type, every third R is replaced by two M's yielding R 2 M 17 compounds. The substitution may be truly random or structured in two ways: so that either the hexagonal structure is maintained or that it is converted into a rhombihedral one. In the second type, one M (in a M 1 position) out of every five is replaced by one R, giving rise to RM 2 compounds which form Laves phases. In the third type, the M 1 's are replaced by R's, resulting in compounds RM 3 . In the fourth type, every third M is replaced by R, yielding R 2 M 7 compounds. With M = Co and R a light lanthanide, the compounds are ferromagnets; with R yttrium, thorium, or a heavy lanthanide, they are ferrimagnets. The preparation of the compounds in an arc-melting apparatus under an Ar-atmosphere followed by annealing is described

  8. Xenobiotic organic compounds in wastewater

    DEFF Research Database (Denmark)

    Eriksson, Eva; Baun, Anders; Henze, Mogens

    2002-01-01

    hundred of XOCs, among them mainly originating from hygiene products: chlorophenols, detergents and phthalates. Several compounds not deriving from hygiene products were also identified e.g. flame-retardants and drugs. A environmental hazard identification showed that a large number of compounds with high...

  9. Devices for collecting chemical compounds

    Science.gov (United States)

    Scott, Jill R; Groenewold, Gary S

    2013-12-24

    A device for sampling chemical compounds from fixed surfaces and related methods are disclosed. The device may include a vacuum source, a chamber and a sorbent material. The device may utilize vacuum extraction to volatilize the chemical compounds from a fixed surface so that they may be sorbed by the sorbent material. The sorbent material may then be analyzed using conventional thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS) instrumentation to determine presence of the chemical compounds. The methods may include detecting release and presence of one or more chemical compounds and determining the efficacy of decontamination. The device may be useful in collection and analysis of a variety of chemical compounds, such as residual chemical warfare agents, chemical attribution signatures and toxic industrial chemicals.

  10. Prevention of Periprosthetic Joint Infection

    Directory of Open Access Journals (Sweden)

    Alisina Shahi

    2015-04-01

    Full Text Available Prosthetic joint infection (PJI is a calamitous complication with high morbidity and substantial cost. The reported incidence is low but it is probably underestimated due to the difficulty in diagnosis. PJI has challenged the orthopaedic community for several years and despite all the advances in this field, it is still a real concern with immense impact on patients, and the healthcare system. Eradication of infection can be very difficult. Therefore, prevention remains the ultimate goal. The medical community has executed many practices with the intention to prevent infection and treat it effectively when it encounters. Numerous factors can predispose patients to PJI. Identifying the host risk factors, patients’ health modification, proper wound care, and optimizing operative room environment remain some of the core fundamental steps that can help minimizing the overall incidence of infection. In this review we have summarized the effective prevention strategies along with the recommendations of a recent International Consensus Meeting on Surgical Site and Periprosthetic Joint Infection.

  11. Progress in JT-60 joint research

    International Nuclear Information System (INIS)

    Kimura, Haruyuki; Kikuchi, Mitsuru; Inutake, Masaaki

    2007-01-01

    It consists of five chapters; 1) introduction, 2) management system of joint plan and researches, 3) progress of joint researches, 4) results of researches and 5) summary. The second chapter stated the structure of management system of JT-60 joint researches, progress of management of the JT-60 experimental theme system, invitation the public to joint researches and selection of the subjects. The progress of joint researches contained the number of subjects, research members and organizations, change of joint research fields, remote control system of experiments, analysis code group, and number of reports. The main results of researches such as development of operation without center solenoid, Magneto-Hydro-Dynamics (MHD) control by electron cyclotron wave, plasma-wall interaction, application of laser technologies to plasma measurement, and comparison between tokamak and helical are reported. (S.Y.)

  12. Joint action without and beyond planning

    DEFF Research Database (Denmark)

    Blomberg, Olle

    2013-01-01

    ” that one must have in order to be a party to a shared intention (consider, for example, the social play of young children or the cooperative hunting of non-human primates or social carnivores). The second lacuna concerns how participants (including adult human agents) are able to coordinate their actions......, to make sense of the idea that joint activities are non-accidentally coordinated. In chapter 3, I offer an account of a kind of joint activity in which agents such as young children and some non-human primates could participate, given what we know about their socio-cognitive capacities. In chapter 4, I...... to perform “our” joint action. I reject this constraint and argue that some joint actions (such as a joint manoeuvre performed by two figure skaters) are joint in virtue of each participant having what I call ‘socially extended intention-in-action’ that overlap. In chapter 5, I review empirical work...

  13. Solder joint technology materials, properties, and reliability

    CERN Document Server

    Tu, King-Ning

    2007-01-01

    Solder joints are ubiquitous in electronic consumer products. The European Union has a directive to ban the use of Pb-based solders in these products on July 1st, 2006. There is an urgent need for an increase in the research and development of Pb-free solders in electronic manufacturing. For example, spontaneous Sn whisker growth and electromigration induced failure in solder joints are serious issues. These reliability issues are quite complicated due to the combined effect of electrical, mechanical, chemical, and thermal forces on solder joints. To improve solder joint reliability, the science of solder joint behavior under various driving forces must be understood. In this book, the advanced materials reliability issues related to copper-tin reaction and electromigration in solder joints are emphasized and methods to prevent these reliability problems are discussed.

  14. MR arthrography of the ankle joint

    International Nuclear Information System (INIS)

    Trattnig, S.; Rand, T.; Breitenseher, M.; Ba-Ssalamah, A.; Schick, S.; Imhof, H.

    1999-01-01

    Due to its superior soft tissue contrast conventional MRI is the imaging method of choice in the evaluation of ankle joint disorders. Conventional MR imaging can accurately demonstrate normal or acutely injured ligaments; however, in subacute and chronic injury joint fluid necessary for delineation of injured ligaments is absent and MR arthrography should be performed. MR arthrography uses the intraarticular injection of contrast material to distend the joint, yielding improved discrimination of intraarticular structures. This joint distension with MR arthrography is also helpful in the staging of osteochondritis dissecans, since in cases of unstable lesions tracking of contrast material into the interface can be more easily demonstrated. Finally, high contrast and joint distension by MR arthrography improves the detection of intraarticular loose bodies, which often require surgery. MR artrography, although invasive, may provide additional information in various ankle joint disorders. (orig.) [de

  15. Flat H Frangible Joint Evolution

    Science.gov (United States)

    Diegelman, Thomas E.; Hinkel, Todd J.; Benjamin, Andrew; Rochon, Brian V.; Brown, Christopher W.

    2016-01-01

    Space vehicle staging and separation events require pyrotechnic devices. They are single-use mechanisms that cannot be tested, nor can failure-tolerant performance be demonstrated in actual flight articles prior to flight use. This necessitates the implementation of a robust design and test approach coupled with a fully redundant, failure-tolerant explosive mechanism to ensure that the system functions even in the event of a single failure. Historically, NASA has followed the single failure-tolerant (SFT) design philosophy for all human-rated spacecraft, including the Space Shuttle Program. Following the end of this program, aerospace companies proposed building the next generation human-rated vehicles with off-the-shelf, non-redundant, zero-failure-tolerant (ZFT) separation systems. Currently, spacecraft and launch vehicle providers for both the Orion and Commercial Crew Programs (CCPs) plan to deviate from the heritage safety approach and NASA's SFT human rating requirements. Both programs' partners have base-lined ZFT frangible joints for vehicle staging and fairing separation. These joints are commercially available from pyrotechnic vendors. Non-human-rated missions have flown them numerous times. The joints are relatively easy to integrate structurally within the spacecraft. In addition, the separation event is debris free, and the resultant pyro shock is lower than that of other design solutions. It is, however, a serious deficiency to lack failure tolerance. When used for critical applications on human-rated vehicles, a single failure could potentially lead to loss of crew (LOC) or loss of mission (LOM)). The Engineering and Safety & Mission Assurance directorates within the NASA Johnson Space Center took action to address this safety issue by initiating a project to develop a fully redundant, SFT frangible joint design, known as the Flat H. Critical to the ability to retrofit on launch vehicles being developed, the SFT mechanisms must fit within the same

  16. Comparative Study of ENIG and ENEPIG as Surface Finishes for a Sn-Ag-Cu Solder Joint

    Science.gov (United States)

    Yoon, Jeong-Won; Noh, Bo-In; Jung, Seung-Boo

    2011-09-01

    Interfacial reactions and joint reliability of Sn-3.0Ag-0.5Cu solder with two different surface finishes, electroless nickel-immersion gold (ENIG) and electroless nickel-electroless palladium-immersion gold (ENEPIG), were evaluated during a reflow process. We first compared the interfacial reactions of the two solder joints and also successfully revealed a connection between the interfacial reaction behavior and mechanical reliability. The Sn-Ag-Cu/ENIG joint exhibited a higher intermetallic compound (IMC) growth rate and a higher consumption rate of the Ni(P) layer than the Sn-Ag-Cu/ENEPIG joint. The presence of the Pd layer in the ENEPIG suppressed the growth of the interfacial IMC layer and the consumption of the Ni(P) layer, resulting in the superior interfacial stability of the solder joint. The shear test results show that the ENIG joint fractured along the interface, exhibiting indications of brittle failure possibly due to the brittle IMC layer. In contrast, the failure of the ENEPIG joint only went through the bulk solder, supporting the idea that the interface is mechanically reliable. The results from this study confirm that the Sn-Ag-Cu/ENEPIG solder joint is mechanically robust and, thus, the combination is a viable option for a Pb-free package system.

  17. Athletes’ Shoulder Joints Traumas Manual Therapy Rehabilitation

    Directory of Open Access Journals (Sweden)

    A.N. Sykhorychko

    2012-06-01

    Full Text Available The examination of 60 athletes, aged 18-30, suffering from chronic pains in shoulder joints was conducted. So, 20 women and 20 men were engaged in track and field and team sports, 15 in weightlifting and strength sports, 5 women in strength sports. Shoulder Joints Traumas Manual Therapy enables to reduce pain syndrome, restore shoulder joint flexibility, normalize trophism after trauma and normalize cervicothoracic transition biomechanics.

  18. Athletes’ Shoulder Joints Traumas Manual Therapy Rehabilitation

    OpenAIRE

    A.N. Sykhorychko; Т.G. Kovalenko; М.А. Sykhorychko

    2012-01-01

    The examination of 60 athletes, aged 18-30, suffering from chronic pains in shoulder joints was conducted. So, 20 women and 20 men were engaged in track and field and team sports, 15 in weightlifting and strength sports, 5 women in strength sports. Shoulder Joints Traumas Manual Therapy enables to reduce pain syndrome, restore shoulder joint flexibility, normalize trophism after trauma and normalize cervicothoracic transition biomechanics.

  19. Internationale joint ventures - udvalgte selskabsretlige problemstillinger

    DEFF Research Database (Denmark)

    Sørensen, Karsten Engsig

    2001-01-01

    Artiklen behandler en række problemstillinger som er særlige for joint ventures stiftet i selskaber af aktie-, anpartsselskabstypen. Bl.a. behandles en række problemer omkring joint venture aftalens forhold til selskabets vedtægter samt en række problemstillinger knyttet til det forhold at der er...... etableret fælles kontrol over joint venture selskabet....

  20. Molecular monitoring of equine joint homeostasis

    OpenAIRE

    de Grauw, J.C.

    2010-01-01

    Chronic joint disorders are a major cause of impaired mobility and loss of quality of life in both humans and horses. Regardless of the primary insult, any joint disorder is characterized by an upset in normal joint homeostasis, the balance between tissue anabolism and catabolism that is normally maintained by resident articular cells. This upset is often fuelled by a local inflammatory response in the synovial membrane and the articular cartilage. Our current understanding of the pathogenesi...

  1. Osteoligamentous injuries of the medial ankle joint.

    Science.gov (United States)

    Lötscher, P; Lang, T H; Zwicky, L; Hintermann, B; Knupp, M

    2015-12-01

    Injuries of the ankle joint have a high incidence in daily life and sports, thus, playing an important socioeconomic role. Therefore, proper diagnosis and adequate treatment are mandatory. While most of the ligament injuries around the ankle joint are treated conservatively, great controversy exists on how to treat deltoid ligament injuries in ankle fractures. Missed injuries and inadequate treatment of the medial ankle lead to inferior outcome with instability, progressive deformity, and ankle joint osteoarthritis.

  2. Joint Global Change Research Institute (JGCRI)

    Data.gov (United States)

    Federal Laboratory Consortium — The Joint Global Change Research Institute (JGCRI) is dedicated to understanding the problems of global climate change and their potential solutions. The Institute...

  3. Joint Experimentation on Scalable Parallel Processors (JESPP)

    National Research Council Canada - National Science Library

    Davis, Dan M; Lucas, Robert F; Yao, Ka-Thia; Wagenbrath, Gene

    2006-01-01

    ...) required expansion of its joint semi-automated forces (JSAF) code capabilities; including number of entities, behavior complexity, terrain resolution, infrastructure features, environmental realism, and analytical potential...

  4. Life Estimation of Hip Joint Prosthesis

    Science.gov (United States)

    Desai, C.; Hirani, H.; Chawla, A.

    2015-07-01

    Hip joint is one of the largest weight-bearing structures in the human body. In the event of a failure of the natural hip joint, it is replaced with an artificial hip joint, known as hip joint prosthesis. The design of hip joint prosthesis must be such so as to resist fatigue failure of hip joint stem as well as bone cement, and minimize wear caused by sliding present between its head and socket. In the present paper an attempt is made to consider both fatigue and wear effects simultaneously in estimating functional-life of the hip joint prosthesis. The finite element modeling of hip joint prosthesis using HyperMesh™ (version 9) has been reported. The static analysis (load due to the dead weight of the body) and dynamic analysis (load due to walking cycle) have been described. Fatigue life is estimated by using the S-N curve of individual materials. To account for progressive wear of hip joint prosthesis, Archard's wear law, modifications in socket geometry and dynamic analysis have been used in a sequential manner. Using such sequential programming reduction in peak stress has been observed with increase in wear. Finally life is estimated on the basis of socket wear.

  5. Joint hypermobility: incidence and some clinical symptoms

    Directory of Open Access Journals (Sweden)

    M P Isaev

    2003-01-01

    Full Text Available Objective. To study joint mobility range among urban population aged 18 to 30 years and to assess association of joint and other connective tissue structures disorders clinical signs with hypermobility. Material and methods. 769 randomly selected individuals aged 18 to 30 (mean - 25,56 years (419 female and 350 male were examined. Hypermobility was assessed with 9-point Beighton scale. Examination included skin stretchability evaluation at elbow back surface, determination of flat feet, high palate, joint pain and deformities of knee joints, joint luxation and subluxation, hand and feet vasospastic disturbances, cardiac pain, oculist examination. Methods of variational statistics were used (x2, Student's test, Spirmen's correlation. Results. Hypermobility incidence and joint mobility in population aged 18 to 30 years in Orenburg largely comply with data received in Moscow. Joint mobility up to 5 points in women and up to 4 points in men is usual for persons of this age and in absence of additional clinical symptoms cannot be considered as pathological. Knee joint deformities, presence of high palate, cardiac pain accompanied by signs of vegetative dysfunction, hand and feet vasospastic disturbances are significantly connected with degree of joint mobility and in some cases can help in hypermobility syndrome diagnosis.

  6. Multi-angle compound imaging

    DEFF Research Database (Denmark)

    Jespersen, Søren Kragh; Wilhjelm, Jens Erik; Sillesen, Henrik

    1998-01-01

    This paper reports on a scanning technique, denoted multi-angle compound imaging (MACI), using spatial compounding. The MACI method also contains elements of frequency compounding, as the transmit frequency is lowered for the highest beam angles in order to reduce grating lobes. Compared to conve......This paper reports on a scanning technique, denoted multi-angle compound imaging (MACI), using spatial compounding. The MACI method also contains elements of frequency compounding, as the transmit frequency is lowered for the highest beam angles in order to reduce grating lobes. Compared...... to conventional B-mode imaging MACI offers better defined tissue boundaries and lower variance of the speckle pattern, resulting in an image with reduced random variations. Design and implementation of a compound imaging system is described, images of rubber tubes and porcine aorta are shown and effects...... on visualization are discussed. The speckle reduction is analyzed numerically and the results are found to be in excellent agreement with existing theory. An investigation of detectability of low-contrast lesions shows significant improvements compared to conventional imaging. Finally, possibilities for improving...

  7. A joint-constraint model for human joints using signed distance-fields

    DEFF Research Database (Denmark)

    Engell-Nørregård, Morten Pol; Abel, Sarah Maria Niebe; Erleben, Kenny

    2012-01-01

    We present a local joint-constraint model for a single joint which is based on distance fields. Our model is fast, general, and well suited for modeling human joints. In this work, we take a geometric approach and model the geometry of the boundary of the feasible region, i.e., the boundary of all...... allowed poses. A region of feasible poses can be built by embedding motion captured data points in a signed distance field. The only assumption is that the feasible poses form a single connected set of angular values. We show how signed distance fields can be used to generate fast and general joint......-joint dependencies, or joints with more than three degrees of freedom. The resolution of the joint-constraints can be tweaked individually for each degree of freedom, which can be used to optimize memory usage. We perform a comparative study of the key-properties of various joint-constraint models, as well...

  8. EPR investigations on technetium compounds

    International Nuclear Information System (INIS)

    Abram, U.; Munze, R.; Kirmse, R.; Stach, J.

    1986-01-01

    Stimulated by the widespread use of the isotope /sup 99m/Tc in the field of nuclear medicine, there has been a substantial growth of interest in the chemistry of this man-made element. A particular need emerges for analytical methods allowing solution investigations of coordination compounds of technetium with low substance use. Considering these facts, Electron Paramagnetic Resonance Spectroscopy (EPR) appears to be a very suitable method because only very small amounts of the compounds are needed (lower than 1 mg). The resulting spectra give information regarding the valence state, symmetry and bonding properties of the compounds under study

  9. Ultrasonic evaluation of friction stud welded AA 6063/AISI 1030 steel joints

    International Nuclear Information System (INIS)

    Hynes, N. Rajesh Jesudoss; Nagaraj, P.; Sujana, J. Angela Jennifa

    2014-01-01

    Highlights: • Friction stud welding of AA 6063 and AISI 1030 was done successfully. • Ultrasonic evaluation of interfacial properties. • EDX analysis confirms intermetallic compound (FeAl) in the interfacial region. - Abstract: Friction stud welding is a promising technique in many applications related to oil and gas industries. It is used to attach grating to offshore oil platforms in areas where arc welding is not permitted because of the risk of causing a fire or explosion. Attachment of anodes inside seawater discharge pipelines in a gas processing plant is performed by this process. This solid state joining process permits metal combinations such as welding of aluminum studs to steel which would be problematic with arc welding because of the formation of thick and brittle inter-metallic compounds. In the present work, AA 6063 is joined to AISI 1030 steel using friction stud welding machine. Properties that are of interest to manufacturing applications such as Young’s modulus, longitudinal velocity, bulk modulus and shear modulus are evaluated by means of an ultrasonic flaw detector. At the interface of the joint, there is an increase of 4.4%, 1.8%, 1.15% and 4.42% is observed for the properties Young’s modulus, longitudinal velocity, bulk modulus and shear modulus respectively. This is due to the formation of intermetallic compound and increase in hardness at the interfacial region. Energy Dispersive X-ray analysis confirms the presence of FeAl as the intermetallic compound. Scanning Electron Microscope evaluation shows the presence of an unbound zone at the center of the inner region which is due to the minimum rotational speed and low axial load experienced at that point. In the unbound zone, there is an incomplete bond between dissimilar metals and it is detrimental to joint strength. Optimum value of friction time and usage of pure aluminum interlayer during the friction stud welding process hinders the formation of unbound zone and enhances the

  10. Osteonecrosis in the knee joint

    International Nuclear Information System (INIS)

    Poeschl, M.

    1981-01-01

    The following forms are discussed: spontaneous osteonecrosis (Ahlbaeck's necrosis), which extends subchondrally into one of the femur condyles. It usually occurs in older patients, especially females. Blunt trauma may cause similar lesions. These often occur with cartilage and bone avulsions (flake fractures), which are often diagnosed much later (arthroscopy). Patellar chondropathy is increasing in frequency due to more intensive participation in sports. Pain localized at the apex of the patella (patellar apex syndrome) can develop from chondropathy, tendon lesions or primary juvenile necrosis of the patellar apex. Gas emboli occur near the knee joint during deep sea diving. Similar cartilage infarctions are seen in many hemoglobinopathies. The incidence of this is increasing due to the increased number of people immigrating from regions were these diseases are common. We have also observed vascular juvenile lesions of the epi- and metaphyses in Klippel-Trenaunay-Weber's syndrome. Their radiological appearance is similar to that of necroses. (orig.) [de

  11. Composite pipe to metal joint

    Energy Technology Data Exchange (ETDEWEB)

    Leslie, James C.; Leslie, II, James C.; Heard, James; Truong, Liem V.; Josephson, Marvin

    2017-06-27

    A method for making a metal to composite tube joint including selecting an elongated interior fitting constructed with an exterior barrel, reduced in exterior diameter to form a distally facing annular shoulder and then projecting still further distally to form an interior sleeve having a radially outwardly facing bonding surface. Selecting an elongated metal outer sleeve formed proximally with a collar constructed for receipt over the barrel and increased in interior diameter and projecting distally to form an exterior sleeve having a radially inwardly facing bonding surface cooperating with the first bonding surface to form an annulus receiving an extremity of a composite tube and a bond bonding the extremity of the tube to the bonding surfaces.

  12. [Temporomandibular joint, occlusion and bruxism].

    Science.gov (United States)

    Orthlieb, J D; Ré, J P; Jeany, M; Giraudeau, A

    2016-09-01

    Temporomandibular joint and dental occlusion are joined for better and worse. TMJ has its own weaknesses, sometimes indicated by bad functional habits and occlusal disorders. Occlusal analysis needs to be addressed simply and clearly. The term "malocclusion" is not reliable to build epidemiological studies, etiologic mechanisms or therapeutic advice on this "diagnosis". Understanding the impact of pathogenic malocclusion is not just about occlusal relationships that are more or less defective, it requires to locate them within the skeletal framework, the articular and behavioural context of the patient, and above all to assess their impact on the functions of the masticatory system. The TMJ-occlusion couple is often symbiotic, developing together in relation to its environment, compensating for its own shortcomings. However, a third partner may alter this relationship, such as bruxism, or more generally oral parafunctions, trauma or an interventionist practitioner. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  13. Pain in the hip joint

    Directory of Open Access Journals (Sweden)

    Yuri Aleksandrovich Olyunin

    2013-01-01

    Full Text Available Pathological changes that develop in the hip joints (HJ have different origins and mechanisms of development, but their main manifestation is pain. The nature of this pain cannot be well established on frequent occasions. The English-language medical literature currently classifies such disorders as greater trochanter pain syndrome (GTPS. Its major signs are chronic pain and local palpatory tenderness in the outer part of HJ. The development of GTPS may be associated with inflammation of the synovial bursae situated in the greater tronchanter, as well as with tendinitis, myorrhexis, iliotibial band syndrome, and other local changes in the adjacent tissues or with systemic diseases. So GTPS may be characterized as regional pain syndrome that frequently mimics pain induced by different diseases, including myofascial pain syndrome, osteoarthrosis, spinal diseases, etc.

  14. Computational Intelligence : International Joint Conference

    CERN Document Server

    Rosa, Agostinho; Cadenas, José; Dourado, António; Madani, Kurosh; Filipe, Joaquim

    2016-01-01

    The present book includes a set of selected extended papers from the sixth International Joint Conference on Computational Intelligence (IJCCI 2014), held in Rome, Italy, from 22 to 24 October 2014. The conference was composed by three co-located conferences:  The International Conference on Evolutionary Computation Theory and Applications (ECTA), the International Conference on Fuzzy Computation Theory and Applications (FCTA), and the International Conference on Neural Computation Theory and Applications (NCTA). Recent progresses in scientific developments and applications in these three areas are reported in this book. IJCCI received 210 submissions, from 51 countries, in all continents. After a double blind paper review performed by the Program Committee, 15% were accepted as full papers and thus selected for oral presentation. Additional papers were accepted as short papers and posters. A further selection was made after the Conference, based also on the assessment of presentation quality and audience in...

  15. Osteonecrosis in the knee joint

    Energy Technology Data Exchange (ETDEWEB)

    Poeschl, M

    1981-12-01

    The following forms are discussed: spontaneous osteonecrosis (Ahlbaeck's necrosis), which extends subchondrally into one of the femur condyles. It usually occurs in older patients, especially females. Blunt trauma may cause similar lesions. These often occur with cartilage and bone avulsions (flake fractures), which are often diagnosed much later (arthroscopy). Patellar chondropathy is increasing in frequency due to more intensive participation in sports. Pain localized at the apex of the patella (patellar apex syndrome) can develop from chondropathy, tendon lesions or primary juvenile necrosis of the patellar apex. Gas emboli occur near the knee joint during deep sea diving. Similar cartilage infarctions are seen in many hemoglobinopathies. The incidence of this is increasing due to the increased number of people immigrating from regions where these diseases are common. We have also observed vascular juvenile lesions of the epi- and metaphyses in Klippel-Trenaunay-Weber's syndrome. Their radiological appearance is similar to that of necroses.

  16. Computational Intelligence : International Joint Conference

    CERN Document Server

    Dourado, António; Rosa, Agostinho; Filipe, Joaquim; Kacprzyk, Janusz

    2016-01-01

    The present book includes a set of selected extended papers from the fifth International Joint Conference on Computational Intelligence (IJCCI 2013), held in Vilamoura, Algarve, Portugal, from 20 to 22 September 2013. The conference was composed by three co-located conferences:  The International Conference on Evolutionary Computation Theory and Applications (ECTA), the International Conference on Fuzzy Computation Theory and Applications (FCTA), and the International Conference on Neural Computation Theory and Applications (NCTA). Recent progresses in scientific developments and applications in these three areas are reported in this book. IJCCI received 111 submissions, from 30 countries, in all continents. After a double blind paper review performed by the Program Committee, only 24 submissions were accepted as full papers and thus selected for oral presentation, leading to a full paper acceptance ratio of 22%. Additional papers were accepted as short papers and posters. A further selection was made after ...

  17. Biofluid lubrication for artificial joints

    Science.gov (United States)

    Pendleton, Alice Mae

    This research investigated biofluid lubrication related to artificial joints using tribological and rheological approaches. Biofluids studied here represent two categories of fluids, base fluids and nanostructured biofluids. Base fluids were studied through comparison of synthetic fluids (simulated body fluid and hyaluronic acid) as well as natural biofluids (from dogs, horses, and humans) in terms of viscosity and fluid shear stress. The nano-structured biofluids were formed using molecules having well-defined shapes. Understanding nano-structured biofluids leads to new ways of design and synthesis of biofluids that are beneficial for artificial joint performance. Experimental approaches were utilized in the present research. This includes basic analysis of biofluids' property, such as viscosity, fluid shear stress, and shear rate using rheological experiments. Tribological investigation and surface characterization were conducted in order to understand effects of molecular and nanostructures on fluid lubrication. Workpiece surface structure and wear mechanisms were investigated using a scanning electron microscope and a transmission electron microscope. The surface topography was examined using a profilometer. The results demonstrated that with the adding of solid additives, such as crown ether or fullerene acted as rough as the other solids in the 3-body wear systems. In addition, the fullerene supplied low friction and low wear, which designates the lubrication purpose of this particular particle system. This dissertation is constructed of six chapters. The first chapter is an introduction to body fluids, as mentioned earlier. After Chapter II, it examines the motivation and approach of the present research, Chapter III discusses the experimental approaches, including materials, experimental setup, and conditions. In Chapter IV, lubrication properties of various fluids are discussed. The tribological properties and performance nanostructured biofluids are

  18. THE RELATIONSHIP BETWEEN TEMPOROMANDIBULAR-JOINT MOBILITY AND PERIPHERAL JOINT MOBILITY RECONSIDERED

    NARCIS (Netherlands)

    Dijkstra, P.U.; DEBONT, L.G.M.; VANDERWEELE, L.T.; Boering, G.

    The purpose of this paper was to study the relationship between temporomandibular joint (TMJ) mobility and mobility of joints and to study the general character of joint mobility in 83 subjects, 55 females and 28 males (mean age 26.7, range 13-46 years). The subjects were recruited from the

  19. Joint Attention in Autism: Teaching Smiling Coordinated with Gaze to Respond to Joint Attention Bids

    Science.gov (United States)

    Krstovska-Guerrero, Ivana; Jones, Emily A.

    2013-01-01

    Children with autism demonstrate early deficits in joint attention and expressions of affect. Interventions to teach joint attention have addressed gaze behavior, gestures, and vocalizations, but have not specifically taught an expression of positive affect such as smiling that tends to occur during joint attention interactions. Intervention was…

  20. 26 CFR 1.6015-1 - Relief from joint and several liability on a joint return.

    Science.gov (United States)

    2010-04-01

    ... they claim losses attributable to H's limited partnership interest in Partnership A. In January 2006... 26 Internal Revenue 13 2010-04-01 2010-04-01 false Relief from joint and several liability on a... joint and several liability on a joint return. (a) In general. (1) An individual who qualifies and...

  1. Stabilization of the sacroiliac joint.

    Science.gov (United States)

    Shaffrey, Christopher I; Smith, Justin S

    2013-07-01

    Lower back pain and pain involving the area of the posterior iliac spine are extremely common. Degeneration of the sacroiliac joint (SIJ) is one potential cause for lower back pain and pain radiating into the groin or buttocks. Degenerative changes to the lumbar spine and sacroiliac joints are common. A recent study evaluating SIJ abnormalities in a primary low back pain population demonstrated 31.7% of patients demonstrated SI joint abnormalities. (4) As is the case for the evaluation and management of isolated lower back pain, the evaluation, management, and role for surgical intervention in SIJ pain is very controversial. Many patients have degenerative changes of the disc, facet joints, and SIJs. A recent systematic review performed to determine the diagnostic accuracy of tests available to clinicians to identify the disc, facet joint, or SIJ as the source of low back pain concluded that tests do exist that change the probability of the disc or SIJ (but not the facet joint) as the source of low back pain. (3) It was also concluded that the usefulness of these tests in clinical practice, particularly for guiding treatment selection, remains unclear. (3) Although there is general agreement that SIJ pathological changes are a potential cause of pain, there is far less agreement about the optimal management of these conditions. A variety of conditions can cause SIJ dysfunction including degenerative and inflammatory arthritis, trauma, prior lumbosacral fusion, hip arthritis, limb length inequality, infections, and neoplasia. (8) There is increasing evidence that image intensifier-guided single periarticular injection can correctly localize pain to the SIJ but the optimal management strategy remains controversial. Recent publications have compared surgical versus injection treatments and fusion versus denervation procedures. (1 , 8) A systematic review found improvement regardless of the treatment, with most studies reporting over 40% improvement in pain as measured

  2. Industrial uses of boron compounds

    Energy Technology Data Exchange (ETDEWEB)

    Pastor, H [Eurotungstene; Thevenot, F

    1978-06-01

    A review includes a section on the use in the chemical industry of some transition-metal borides as heterogeneous catalysts in the hydrogenation and dehydrogenation of organic compounds and in fuel cells.

  3. The demise of compound houses

    DEFF Research Database (Denmark)

    Andreasen, Jørgen; Eskemose Andersen, Jørgen

    2006-01-01

    of compound housing and analyses the advantages and disadvantages of life within such housing in Kumasi. Issues of privacy, image and communal life are usually cited by occupants dissatiesfied with life in compound houses, and the difficulty of extending them without spoiling the open spaces...... perceptions of what is acceptable urban life to the growing cohort of young African households. In addition, there is a need to explore innovative forms of tenure in order to secure the majority of Kumasi's population access to land for housing.......The compound house has long provided the accomodation required by low income households in West African cities. In Kumasi, Ghana, evidence suggests that no new compounds are being built. Instead, the city is being ringed by relatively affluent villa-style development while neighbourhoods dominated...

  4. Detection of chlorinated aromatic compounds

    Science.gov (United States)

    Ekechukwu, A.A.

    1996-02-06

    A method for making a composition for measuring the concentration of chlorinated aromatic compounds in aqueous fluids, and an optical probe for use with the method are disclosed. The composition comprises a hydrophobic polymer matrix, preferably polyamide, with a fluorescent indicator uniformly dispersed therein. The indicator fluoresces in the presence of the chlorinated aromatic compounds with an intensity dependent on the concentration of these compounds in the fluid of interest, such as 8-amino-2-naphthalene sulfonate. The probe includes a hollow cylindrical housing that contains the composition in its distal end. The probe admits an aqueous fluid to the probe interior for exposure to the composition. An optical fiber transmits excitation light from a remote source to the composition while the indicator reacts with chlorinated aromatic compounds present in the fluid. The resulting fluorescence light signal is reflected to a second optical fiber that transmits the light to a spectrophotometer for analysis. 5 figs.

  5. Third Symposium on Macrocyclic Compounds

    International Nuclear Information System (INIS)

    1979-01-01

    At the Third Symposium on Macrocyclic Compounds there were sessions on facilitated transport, analytical applications, organic synthesis and reactions, phase transfer catalysis, and metal complexation. Abstracts of the individual presentations are included

  6. Quality control of labelled compounds

    International Nuclear Information System (INIS)

    Matucha, M.

    1979-01-01

    Some advantages and disadvantages of methods used for quality control of organic labelled compounds (1 31 I, 14 C) are shortly discussed. The methods used are electrophoresis, ultraviolet and infrared spectrometry, radiogas and thin-layer chromatography. (author)

  7. Compound cueing in free recall

    Science.gov (United States)

    Lohnas, Lynn J.; Kahana, Michael J.

    2013-01-01

    According to the retrieved context theory of episodic memory, the cue for recall of an item is a weighted sum of recently activated cognitive states, including previously recalled and studied items as well as their associations. We show that this theory predicts there should be compound cueing in free recall. Specifically, the temporal contiguity effect should be greater when the two most recently recalled items were studied in contiguous list positions. A meta-analysis of published free recall experiments demonstrates evidence for compound cueing in both conditional response probabilities and inter-response times. To help rule out a rehearsal-based account of these compound cueing effects, we conducted an experiment with immediate, delayed and continual-distractor free recall conditions. Consistent with retrieved context theory but not with a rehearsal-based account, compound cueing was present in all conditions, and was not significantly influenced by the presence of interitem distractors. PMID:23957364

  8. Compound cuing in free recall.

    Science.gov (United States)

    Lohnas, Lynn J; Kahana, Michael J

    2014-01-01

    According to the retrieved context theory of episodic memory, the cue for recall of an item is a weighted sum of recently activated cognitive states, including previously recalled and studied items as well as their associations. We show that this theory predicts there should be compound cuing in free recall. Specifically, the temporal contiguity effect should be greater when the 2 most recently recalled items were studied in contiguous list positions. A meta-analysis of published free recall experiments demonstrates evidence for compound cuing in both conditional response probabilities and interresponse times. To help rule out a rehearsal-based account of these compound cuing effects, we conducted an experiment with immediate, delayed, and continual-distractor free recall conditions. Consistent with retrieved context theory but not with a rehearsal-based account, compound cuing was present in all conditions, and was not significantly influenced by the presence of interitem distractors.

  9. Crystallographic properties of fertilizer compounds

    Energy Technology Data Exchange (ETDEWEB)

    Frazier, A.W.; Dillard, E.F.; Thrasher, R.D.; Waerstad, K.R.; Hunter, S.R.; Kohler, J.J.; Scheib, R.M.

    1991-02-01

    This bulletin is a compilation of crystallographic data collected at NFERC on 450 fertilizer-related compounds. In TVA's fertilizer R and D program, petrographic examination, XRD, and infrared spectroscopy are combined with conventional chemical analysis methods in identifying the individual compounds that occur in fertilizer materials. This handbook brings together the results of these characterization studies and supplemental crystallographic data from the literature. It is in one-compound-per-page, loose-leaf format, ordered alphabetically by IUPAC name. Indexes provided include IUPAC name, formula, group, alternate formula, synonyms, x-ray data, optical data. Tables are given for solids, compounds in commercial MAP and DAP, and matrix materials in phosphate rock.

  10. Polishing compound for plastic surfaces

    Science.gov (United States)

    Stowell, M.S.

    1991-01-01

    This invention is comprised of a polishing compound for plastic materials. The compound includes approximately by approximately by weight 25 to 80 parts at least one petroleum distillate lubricant, 1 to 12 parts mineral spirits, 50 to 155 parts abrasive paste, and 15 to 60 parts water. Preferably, the compound includes approximately 37 to 42 parts at least one petroleum distillate lubricant, up to 8 parts mineral spirits, 95 to 110 parts abrasive paste, and 50 to 55 parts water. The proportions of the ingredients are varied in accordance with the particular application. The compound is used on PLEXIGLAS{trademark}, LEXAN{trademark}, LUCITE{trademark}, polyvinyl chloride (PVC), and similar plastic materials whenever a smooth, clear polished surface is desired.

  11. Phenolic Compounds in Brassica Vegetables

    Directory of Open Access Journals (Sweden)

    Pablo Velasco

    2010-12-01

    Full Text Available Phenolic compounds are a large group of phytochemicals widespread in the plant kingdom. Depending on their structure they can be classified into simple phenols, phenolic acids, hydroxycinnamic acid derivatives and flavonoids. Phenolic compounds have received considerable attention for being potentially protective factors against cancer and heart diseases, in part because of their potent antioxidative properties and their ubiquity in a wide range of commonly consumed foods of plant origin. The Brassicaceae family includes a wide range of horticultural crops, some of them with economic significance and extensively used in the diet throughout the world. The phenolic composition of Brassica vegetables has been recently investigated and, nowadays, the profile of different Brassica species is well established. Here, we review the significance of phenolic compounds as a source of beneficial compounds for human health and the influence of environmental conditions and processing mechanisms on the phenolic composition of Brassica vegetables.

  12. Fourth symposium on macrocyclic compounds

    International Nuclear Information System (INIS)

    Christensen, J.J.; Izatt, R.M.

    1980-01-01

    Both theoretical and experimental aspects of the properties and behavior of synthetic and naturally occurring macrocyclic compounds are covered in this symposium. This document contains abstracts of the papers

  13. Radiation curable hydantoin diacrylate compounds

    International Nuclear Information System (INIS)

    Seltzer, R.; DiPrima, J.F.

    1979-01-01

    The diacrylate compounds are liquid at room temperature, easily processable as adhesives, casting and laminating resins and when cured possess excellent resistance to water. These compositions are easily cured exposure to ionizing radiations

  14. Joint formation of dissimilar steels in pressure welding with superposition of ultrasonic oscillations

    Energy Technology Data Exchange (ETDEWEB)

    Surovtsev, A P; Golovanenko, S A; Sukhanov, V E; Kazantsev, V F

    1983-12-01

    Investigation results of kinetics and quality of carbon steel joints with the steel 12Kh18N10T, obtained by pressure welding with superposition of ultrasonic oscillations with the frequency 16.5-18.0 kHz are given. The effect of ultrasonic oscillations on the process of physical contact development of the surfaces welded, formation of microstructure and impact viscosity of the compound, is shown.

  15. Inorganic, coordination and organometallic compounds

    International Nuclear Information System (INIS)

    Jursik, F.

    1978-01-01

    Separation of cations and anions of inorganic, coordination and metalloorganic compounds by the method of liquid column chromatography is considered. Common scheme of multicomponent cation mixture is suggesteed. Separation conditions, adsrbents, eluents, pH value solution concenstration, elution rate are also suggested. Separation of rare earth elements Cs, Be, Cd, Te, Th, U, Mo, Re, V, Ru, Zr, In compounds is considered as an example of liquid column chromatography application. Data on column chromatography application are summarized in a table

  16. The Role of Mechanical Connection during Friction Stir Keyholeless Spot Welding Joints of Dissimilar Materials

    Directory of Open Access Journals (Sweden)

    Xiao Liu

    2017-06-01

    Full Text Available Contrast experiments of lap joints among dissimilar AZ31B Mg alloy, Mg99.50, zinc-coated DP600 sheet, and non-zinc-coated DP600 sheet were made by friction stir keyholeless spot welding (FSKSW and vacuum diffusion welding (VDW, respectively. Scanning electron microscopy (SEM and energy disperse spectroscopy (EDS were used to investigate the microstructures and components of the joints welded. The experimental results show that the FSKSW bonding method is a kind of compound mode that contains a mechanical connection and element diffusion fusion connection, in which mechanical connection has the main decisive function on joints of Mg/steel. Elements diffusion exists in the interfacial region of the joints and the elements diffusion extent is basically the same to that of VDW. The elements’ diffusion in Mg/steel using FSKSW is defined in the reaction between small amounts elements of the base metal and zinc-coated metals. The intermetallic compounds and composite oxide perform some reinforcement on the mechanical connection strength.

  17. Compound Odontoma in young girl

    Directory of Open Access Journals (Sweden)

    Nurwahida Nurwahida

    2017-08-01

    Full Text Available Introduction. Odontomas are the most common type of odontogenic tumors and generally they are asymptomatic. These tumors are formed from enamel and dentin, and can have variable amounts of cement and pulp tissues. According to radiographic, microscopic, and clinical features, two types of odontomas are recognized: Complex and compound odontomas. Complex odontomas occur mostly in the posterior part of the mandible and compound odontomas in the anterior maxilla. Case Report. A young girl patient, 9 years old came to Department of Oral and Maxillofacial Surgery with a slow growing and asymptomatic swelling in her left posterior mandible for 5 years in his history taking. The panoramic radiograph show  a radioopacity and radiolucent lesion at the lower second molar region, with well-corticated limits. An insisional biopsi   confirmed  as compound odontoma. The surgery  performed with simple enucleation and curettage under general anaesthesia. Discussion. Compound odontomas are usually located in the anterior maxilla, over the crowns of unerupted teeth, or between the roots of erupted teeth. In this case report, Compound odontomas are found in the posterior mandible. Conclusion. Compound odontomas in the posterior mandible is a rare. The treatment of odontomas depends on the size of the lesion. The early diagnosis, the treatment of choice is conservative surgical enucleation and curettage and prognosis is excellent.

  18. 29 CFR 791.2 - Joint employment.

    Science.gov (United States)

    2010-07-01

    ... the Act. In this event, all joint employers are responsible, both individually and jointly, for... they have. Of course, an employer should not be held responsible for an employee's action in seeking... two or more employers at the same time under the Fair Labor Standards Act of 1938, since there is...

  19. 38 CFR 4.66 - Sacroiliac joint.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Sacroiliac joint. 4.66... DISABILITIES Disability Ratings The Musculoskeletal System § 4.66 Sacroiliac joint. The common cause of disability in this region is arthritis, to be identified in the usual manner. The lumbosacral and sacroiliac...

  20. Innervation of the Anterior Sacroiliac Joint.

    Science.gov (United States)

    Cox, Marcus; Ng, Garrett; Mashriqi, Faizullah; Iwanaga, Joe; Alonso, Fernando; Tubbs, Kevin; Loukas, Marios; Oskouian, Rod J; Tubbs, R Shane

    2017-11-01

    Sacroiliac joint pain can be disabling and recalcitrant to medical therapy. The innervation of this joint is poorly understood, especially its anterior aspect. Therefore, the present cadaveric study was performed to better elucidate this anatomy. Twenty-four cadaveric sides underwent dissection of the anterior sacroiliac joint, with special attention given to any branches from regional nerves to this joint. No femoral, obturator, or lumbosacral trunk branches destined to the anterior sacroiliac joint were identified in the 24 sides. In 20 sides, one or two small branches (less than 0.5 mm in diameter) were found to arise from the L4 ventral ramus (10%), the L5 ventral ramus (80%), or simultaneously from both the L4 and L5 ventral rami (10%). The length of the branches ranged from 5 to 31 mm (mean, 14 mm). All these branches arose from the posterior part of the nerves and traveled to the anterior surface of the sacroiliac joint. No statistical significance was found between sides or sexes. An improved knowledge of the innervation of the anterior sacroiliac joint might decrease suffering in patients with chronic sacroiliac joint pain. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Osteoblastoma crossing the sacro-iliac joint

    Energy Technology Data Exchange (ETDEWEB)

    Whittingham-Jones, Paul; Lehovsky, Jan [Royal National Orthopaedic Hospital, Spinal Surgery, London (United Kingdom); Hughes, Richard; Saifuddin, Asif [Royal National Orthopaedic Hospital, Radiology, London (United Kingdom); Fajinmi, Matilda [Royal National Orthopaedic Hospital, Histopathology, London (United Kingdom)

    2007-03-15

    Osteoblastoma is a rare primary bone tumour which is well-described in the spine and sacrum. We report a case of histologically confirmed osteoblastoma in a 20-year-old male which crossed the sacroiliac joint. This has not previously been described to our knowledge. The imaging features of osteoblastoma and sacroiliac joint involvement by bone tumours are reviewed. (orig.)

  2. Creep behavior evaluation of welded joint

    International Nuclear Information System (INIS)

    Susei, Shuzo; Matsui, Shigetomo; Mori, Eisuke; Shimizu, Shigeki; Satoh, Keisuke.

    1980-01-01

    In the creep design of high temperature structural elements, it is necessary to grasp the creep performance of joints as a whole, paying attention to the essential lack of uniformity between the material qualities of parent metals and welds. In this study, the factors controlling the creep performance of butt welded joints were investigated theoretically, when they were subjected to lateral tension and longitudinal tension. It was clarified that the rupture time in the case of laterally pulled joints was determined by the ratio of the creep rupture times of weld metals and parent metals, and the rupture time in the case of longitudinally pulled joints was determined by the ratio of the creep rupture times and the ratio of the creep strain rates of weld metals and parent metals. Moreover, when the joints of the former ratio less than 1 and the latter ratio larger than 1 were investigated experimentally, the rupture time in the case of laterally pulled joints was affected by the relative thickness, and when the relative thickness was large, the theoretical and the experimental values coincided, but the relative thickness was small, the theoretical values gave the evaluation on safe side as compared with the experimental values due to the effect of restricting deformation. In the case of longitudinally pulled joints, the theoretical and the experimental values coincided relatively well. The diagram of classifying the creep performance of welded joints was proposed. (Kako, I.)

  3. Cooperative Engineering as a Joint Action

    Science.gov (United States)

    Joffredo-Le Brun, Sophie; Morellato, Mireille; Sensevy, Gérard; Quilio, Serge

    2018-01-01

    This paper describes some elements of a specific kind of design-based research, cooperative engineering. In the first part of the paper, we argue that cooperative engineering can be analyzed through a joint action framework. We first present some conceptual tools that the Joint Action Theory in Didactics proposes in order to understand didactic…

  4. 14 CFR 399.37 - Joint fares.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Joint fares. 399.37 Section 399.37 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) POLICY STATEMENTS STATEMENTS OF GENERAL POLICY Policies Relating to Rates and Tariffs § 399.37 Joint fares. There...

  5. ECOWindS Joint Action Plan

    DEFF Research Database (Denmark)

    2014-01-01

    The Joint Action Plan (JAP) is a deliverable of the ECOWindS project Work Package 4 (WP4) “Joint Action Plan”. It presents a plan of action or a roadmap for research, development, and innovation (RDI) for the Offshore Wind Service (OWS) industry. The objective of the JAP is to be an international...

  6. CHECKing radiographic joint damage in early osteoarthritis

    NARCIS (Netherlands)

    Kinds, M.B.

    2012-01-01

    Osteoarthritis Osteoarthritis (OA) is the most common joint disease, characterized by pain and functional disability. OA commonly involves the larger joints, with symptomatic knee and hip OA affecting 6% and 3% of the adult population (age 30 years and over), respectively. The prevalence and disease

  7. The joint venture alternative to mergers.

    Science.gov (United States)

    Enders, R J

    1995-02-01

    However, while a joint venture may be "safe" from antitrust challenge, it is not without some practical difficulties, especially with respect to consolidating services at one location or jointly offering services provided at multiple facilities. These practical concerns include: 1. Who will exercise operational management of the joint venture? 2. How will the joint venture deal with different pricing for services that will be provided at multiple locations? 3. What criteria will be used to decide the location at which consolidated tertiary services will be offered? 4. In what circumstances can the joint venture be unwound, either in its entirety or as to discrete functions? When clinical services have been consolidated at one location, there is an appropriate concern by the other hospital that it will be unable to provide or re-enter the market for those services if the joint venture dissolves. These operational concerns, of course, are not addressed in the Consent Decree. Thus, even if a joint venture relationship survives antitrust scrutiny, the parties must still negotiate and resolve these operational issues in order for the joint venture to be viable.

  8. Joint Ventures: A New Agenda for Education.

    Science.gov (United States)

    Griffin, Dean

    1989-01-01

    The author states that vocational education can join in partnerships with industry, labor, and government to contribute to economic development. Examples of current programs are included. The "joint venture" concept is explained and ideas for forming joint ventures are shared. (CH)

  9. THE METHOD OF KNEE JOINT ARTHRODESIS

    Directory of Open Access Journals (Sweden)

    V. G. Fedorov

    2011-01-01

    Full Text Available The usage of bone plastics by cylindrical autotransplant in cases of posttraumatic changes of knee joint is described. Knee joint arthrodesis is supposed to be used as alternate in term of replacement impossibility (for example, high-grade deformity, the age (osteoporosis, concomitant diseases that can lead to complicate operation.

  10. Vitamin K, osteoarthritis, and joint pain

    Science.gov (United States)

    Osteoarthritis is the leading cause of joint pain and lower extremity disability in older adults and there is no known cure. Vitamin K has been implicated on osteoarthritis because vitamin K dependent proteins are present in joint tissues, such as cartilage and bone. In order to function, vitamin K ...

  11. Joint route planning under varying market conditions

    NARCIS (Netherlands)

    Cruijssen, Frans; Bräysy, Olli; Dullaert, Wout; Fleuren, Hein; Salomon, Marc

    2007-01-01

    Purpose - To provide empirical evidence on the level of savings that can be attained by joint route planning and how these savings depend on specific market characteristics. Design/methodology/approach - Joint route planning is a measure that companies can take to decrease the costs of their

  12. Fabrication of high-quality brazed joints

    International Nuclear Information System (INIS)

    Orlov, A.V.

    1980-01-01

    Problem of ensuring of joint high-quality when brazing different parts in power engineering is considered. To obtain high-quality joints it is necessary to correctly design brazed joint and to choose a gap width, overlap length and fillet radius; to clean up carefully the surfaces to be brazed and fix them properly one relative to another; to apply a solder so as to provide its flowing into the gap and sticking in it; to exactly regulate thermal conditions of brazing. High quality and reliability of brazed joints are ensured by the application of solders based on noble metals, and cheap solders based on nickel, manganese and copper. Joints brazed with nickel base solders may operate at temperatures as high as 888 deg C

  13. A minimal architecture for joint action

    DEFF Research Database (Denmark)

    Vesper, Cordula; Butterfill, Stephen; Knoblich, Günther

    2010-01-01

    What kinds of processes and representations make joint action possible? In this paper we suggest a minimal architecture for joint action that focuses on representations, action monitoring and action prediction processes, as well as ways of simplifying coordination. The architecture spells out...... minimal requirements for an individual agent to engage in a joint action. We discuss existing evidence in support of the architecture as well as open questions that remain to be empirically addressed. In addition, we suggest possible interfaces between the minimal architecture and other approaches...... to joint action. The minimal architecture has implications for theorizing about the emergence of joint action, for human-machine interaction, and for understanding how coordination can be facilitated by exploiting relations between multiple agents’ actions and between actions and the environment....

  14. Architectural and structural qualities in timber joints

    DEFF Research Database (Denmark)

    Christensen, Jesper Thøger; Christensen, Mogens Fiil; Damkilde, Lars

    2016-01-01

    Design of joints in timber structures is crucial to reach both elegant and structural efficient designs. Design of joints should therefore be an integral part of the conceptual design phase. Traditionally this is not the case, and joints are often solely designed and analysed in the engineering...... but also increase timbers competitiveness in the building industry. The paper is part of an ongoing research project aiming at providing tools for an integrated design process for timber structures. The focus of the paper is to identify how structure and its joints contributes to architecture and vice...... design phase. The result is joints that function structurally but do not add value to the design, and may even compromise the architectural ideas. With an approach, integrating both structural and architectural design from the beginning, one should not only gain better structures and architecture...

  15. Management of chronic unstable acromioclavicular joint injuries.

    Science.gov (United States)

    Cisneros, Luis Natera; Reiriz, Juan Sarasquete

    2017-12-01

    The acromioclavicular joint represents the link between the clavicle and the scapula, which is responsible for the synchronized dynamic of the shoulder girdle. Chronic acromioclavicular joint instability involves changes in the orientation of the scapula, which provokes cinematic alterations that might result in chronic pain. Several surgical strategies for the management of patients with chronic and symptomatic acromioclavicular joint instability have been described. The range of possibilities includes anatomical and non-anatomical techniques, open and arthroscopy-assisted procedures, and biological and synthetic grafts. Surgical management of chronic acromioclavicular joint instability should involve the reconstruction of the torn ligaments because it is accepted that from three weeks after the injury, these structures may lack healing potential. Here, we provide a review of the literature regarding the management of chronic acromioclavicular joint instability. Expert opinion, Level V.

  16. Excluding joint probabilities from quantum theory

    Science.gov (United States)

    Allahverdyan, Armen E.; Danageozian, Arshag

    2018-03-01

    Quantum theory does not provide a unique definition for the joint probability of two noncommuting observables, which is the next important question after the Born's probability for a single observable. Instead, various definitions were suggested, e.g., via quasiprobabilities or via hidden-variable theories. After reviewing open issues of the joint probability, we relate it to quantum imprecise probabilities, which are noncontextual and are consistent with all constraints expected from a quantum probability. We study two noncommuting observables in a two-dimensional Hilbert space and show that there is no precise joint probability that applies for any quantum state and is consistent with imprecise probabilities. This contrasts with theorems by Bell and Kochen-Specker that exclude joint probabilities for more than two noncommuting observables, in Hilbert space with dimension larger than two. If measurement contexts are included into the definition, joint probabilities are not excluded anymore, but they are still constrained by imprecise probabilities.

  17. Anatomy and histology of the sacroiliac joints.

    Science.gov (United States)

    Egund, Niels; Jurik, Anne Grethe

    2014-07-01

    The anatomy of joints provides an important basis for understanding the nature and imaging of pathologic lesions and their imaging appearance. This applies especially to the sacroiliac (SI) joints, which play a major role in the diagnosis of spondyloarthritis. They are composed of two different joint portions, a cartilage-covered portion ventrally and a ligamentous portion dorsally, and thus rather complex anatomically. Knowledge of anatomy and the corresponding normal imaging findings are important in the imaging diagnosis of sacroiliitis, especially by MR imaging. A certain distinction between the two joint portions by MR imaging is only obtainable by axial slice orientation. Together with a perpendicular coronal slice orientation, it provides adequate anatomical information and thereby a possibility for detecting the anatomical site of disease-specific characteristics and normal variants simulating disease. This overview describes current knowledge about the normal macroscopic and microscopic anatomy of the SI joints. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. Of bugs and joints: the relationship between infection and joints.

    Science.gov (United States)

    Espinoza, Luis R; García-Valladares, Ignacio

    2013-01-01

    The association between microbes and joints has existed since antiquity, and remains complex. Diagnosis is often times difficult to determine despite highly suspicious clinical characteristics for the presence of an underlying infection. Over the several past decades, considerable advances have occurred in diagnostic methodologies and therapy. However, the morbidity and mortality of septic arthritis remains high. Great advances have occurred in the diagnosis, pathogenesis, and therapeutic management of reactive arthritis, and there is evidence that when the responsible microorganism is Chlamydia trachomathis, complete remission and cure is possible. Emergent infections, especially viral, has been recognized, i.e. HIV, hepatitis C, and most recently Chikengunya virus, and in the case of HIV associated articular manifestations, the introduction of HAART has resulted in a decrease in the incidence and development of newer complications such as the immune reconstitution syndrome. The infectious etiology of rheumatoid arthritis is being strongly considered once again, and the exciting association with periodontal disease is at the forefront of intense research. The gut microbiota is also being investigated and new and most interesting data is being gathered of the potential role of commensal gut organisms and the pathogenesis of rheumatoid arthritis. Copyright © 2011 Elsevier España, S.L. All rights reserved.

  19. Effects of filling material and laser power on the formation of intermetallic compounds during laser-assisted friction stir butt welding of steel and aluminum alloys

    Science.gov (United States)

    Fei, Xinjiang; Jin, Xiangzhong; Peng, Nanxiang; Ye, Ying; Wu, Sigen; Dai, Houfu

    2016-11-01

    In this paper, two kinds of materials, Ni and Zn, are selected as filling material during laser-assisted friction stir butt welding of Q235 steel and 6061-T6 aluminum alloy, and their influences on the formation of intermetallic compounds on the steel/aluminum interface of the joints were first studied. SEM was used to analyze the profile of the intermetallic compound layer and the fractography of tensile fracture surfaces. In addition, EDS was applied to investigate the types of the intermetallic compounds. The results indicate that a thin iron-abundant intermetallic compound layer forms and ductile fracture mode occurs when Ni is added, but a thick aluminum-abundant intermetallic compound layer generates and brittle fracture mode occurs when Zn is added. So the tensile strength of the welds with Ni as filling material is greater than that with Zn as filling material. Besides, the effect of laser power on the formation of intermetallic compound layer when Ni is added was investigated. The preheated temperature field produced by laser beam in the cross section of workpiece was calculated, and the tensile strength of the joints at different laser powers was tested. Results show that only when suitable laser power is adopted, can suitable preheating temperature of the steel reach, then can thin intermetallic compound layer form and high tensile strength of the joints reach. Either excessive or insufficient laser power will reduce the tensile strength of the joints.

  20. Thorax deformity, joint hypermobility and anxiety disorder

    International Nuclear Information System (INIS)

    Gulsun, M.; Dumlu, K.; Erbas, M.; Yilmaz, Mehmet B.; Pinar, M.; Tonbul, M.; Celik, C.; Ozdemir, B.

    2007-01-01

    Objective was to evaluate the association between thorax deformities, panic disorder and joint hypermobility. The study includes 52 males diagnosed with thorax deformity, and 40 healthy male controls without thorax deformity, in Tatvan Bitlis and Isparta, Turkey. The study was carried out from 2004 to 2006. The teleradiographic and thoracic lateral images of the subjects were evaluated to obtain the Beighton scores; subjects psychiatric conditions were evaluated using the Structured Clinical Interview for DSM-IV Axis I Disorders (SCID-1), and the Hamilton Anxiety Scale (HAM-A) was applied in order to determine the anxiety levels. Both the subjects and controls were compared in sociodemographic, anxiety levels and joint mobility levels. In addition, males with joint hypermobility and thorax deformity were compared to the group with thorax deformity without joint hypermobility. A significant difference in HAM-A scores was found between the groups with thorax deformity and without. In addition, 21 subjects with thorax deformity met the joint hypermobility criteria in the group with thorax deformity and 7 subjects without thorax deformity met the joint hypermobility criteria in the group without thorax deformity, according to Beighton scoring. The Beighton score of subjects with thorax deformity were significantly different from those of the group without deformity. Additionally, anxiety scores of the males with thorax deformity and joint hypermobility were found higher than males with thorax deformity without joint hypermobility. Anxiety disorders, particularly panic disorder, have a significantly higher distribution in males subjects with thorax deformity compared to the healthy control group. In addition, the anxiety level of males with thorax deformity and joint hypermobility is higher than males with thorax deformity without joint hypermobility. (author)

  1. Temporomandibular joint involvement caused by Borrelia Burgdorferi.

    Science.gov (United States)

    Lesnicar, Gorazd; Zerdoner, Danijel

    2007-12-01

    Lyme borreliosis is an endemic disease in Slovenia with an incidence of around 150 patients per 100,000 inhabitants. Although the large joints are most typically affected in Lyme borreliosis, there are also periods of disease activity with arthritis or arthralgias involving smaller joints, including the temporo-mandibular joint. During the years between 2000 and 2003, two patients with Lyme borreliosis affecting the temporo-mandibular joints were treated. The patients presented with fatigue and pain in diverse muscle groups accompanied by arthralgia, which was most pronounced in the temporomandibular joint area. None of the patients were febrile or had joint effusions. Both patients were examined by means of biochemical and serological examinations for Borrelia burgdorferi using ELISA assay and Western blot test (both for IgM and IgG), plain radiographs, MR and CT scans, and scinti-scan of the temporo-mandibular joints They both had positive serum markers for an acute B. burgdorferi infection and were treated with intravenous ceftriaxone. None of the patients had clinical or laboratory signs of chronic Lyme disease activity two and four years following therapy, respectively. Roentgenographic and nuclear magnetic resonance imaging of the temporo-mandibular joints had not shown any persistent sign of acute inflammation. There are only few reports of patients with manifest temporo-mandibular joint involvement of Lyme borreliosis in the literature. This report emphasizes the importance of differential diagnosis of acute temporo-mandibular joint arthralgia, of early diagnosis of Lyme borreliosis, and of the necessity for prompt antibiotic treatment.

  2. Joint Laxity in Preschool Children Born Preterm.

    Science.gov (United States)

    Romeo, Domenico M; Velli, Chiara; Lucibello, Simona; Ferrantini, Gloria; Leo, Giuseppina; Brogna, Claudia; Cota, Francesco; Ricci, Daniela; Gallini, Francesca; Romagnoli, Costantino; Vento, Giovanni; Mercuri, Eugenio

    2018-06-01

    To evaluate the prevalence of joint laxity in children born preterm assessed in the first 2 years, the relationship between joint laxity and motor performance at preschool age, and possible changes over time in a subgroup of children followed longitudinally. The revised scale of Beighton Score was used to evaluate joint laxity in a population of 132 preschool children born preterm between 24 and 32 weeks of gestational age. All were assessed for joint laxity between 12 and 24 months of age. Children also performed the Movement Assessment Battery for Children-Second Edition between the age of 3 years and 6 months and 4 years; the age at onset of independent walking also was recorded. The total Beighton Score ranged between 0 and 8. Twenty percent of the cohort showed joint laxity. No differences related to sex or gestational age were observed. Children born preterm with joint laxity achieved later independent walking and achieved lower scores on Movement Assessment Battery for Children-Second Edition than those without joint laxity. In 76 children born preterm, an assessment for joint laxity was repeated once between 25 and 36 months and again after >36 months. No statistically significant difference was observed between the 3 assessments. The Beighton Score can be used to assess generalized joint laxity in children born preterm. As the presence of joint laxity influenced motor competences, the possibility to early identify these infants in the first 2 years is of interest to benefit from early intervention and potentially improve gross motor skills and coordination. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. The joint flanker effect and the joint Simon effect: On the comparability of processes underlying joint compatibility effects.

    Science.gov (United States)

    Dittrich, Kerstin; Bossert, Marie-Luise; Rothe-Wulf, Annelie; Klauer, Karl Christoph

    2017-09-01

    Previous studies observed compatibility effects in different interference paradigms such as the Simon and flanker task even when the task was distributed across two co-actors. In both Simon and flanker tasks, performance is improved in compatible trials relative to incompatible trials if one actor works on the task alone as well as if two co-actors share the task. These findings have been taken to indicate that actors automatically co-represent their co-actor's task. However, recent research on the joint Simon and joint flanker effect suggests alternative non-social interpretations. To which degree both joint effects are driven by the same underlying processes is the question of the present study, and it was scrutinized by manipulating the visibility of the co-actor. While the joint Simon effect was not affected by the visibility of the co-actor, the joint flanker effect was reduced when participants did not see their co-actors but knew where the co-actors were seated. These findings provide further evidence for a spatial interpretation of the joint Simon effect. In contrast to recent claims, however, we propose a new explanation of the joint flanker effect that attributes the effect to an impairment in the focusing of spatial attention contingent on the visibility of the co-actor.

  4. A New Method for Determination of Joint Roughness Coefficient of Rock Joints

    Directory of Open Access Journals (Sweden)

    Shigui Du

    2015-01-01

    Full Text Available The joint roughness coefficient (JRC of rock joints has the characteristic of scale effect. JRC measured on small-size exposed rock joints should be evaluated by JRC scale effect in order to obtain the JRC of actual-scale rock joints, since field rock joints are hardly fully exposed or well saved. Based on the validity analysis of JRC scale effect, concepts of rate of JRC scale effect and effective length of JRC scale effect were proposed. Then, a graphic method for determination of the effective length of JRC scale effect was established. Study results show that the JRC of actual-scale rock joints can be obtained through a fractal model of JRC scale effect according to the statistically measured results of the JRC of small-size partial exposed rock joints and by the selection of fractal dimension of JRC scale effect and the determination of effective length of JRC scale effect.

  5. Diazo compounds in the chemistry of fullerenes

    International Nuclear Information System (INIS)

    Tuktarov, Airat R; Dzhemilev, Usein M

    2010-01-01

    Experimental and theoretical data on the reactions of different diazo compounds (diazomethane, its derivatives, cyclic diazo compounds and diazocarbonyl compounds) with fullerenes are summarized. The structures and stereochemistry of cycloadducts formed in these reactions are considered.

  6. Diazo compounds in the chemistry of fullerenes

    Science.gov (United States)

    Tuktarov, Airat R.; Dzhemilev, Usein M.

    2010-09-01

    Experimental and theoretical data on the reactions of different diazo compounds (diazomethane, its derivatives, cyclic diazo compounds and diazocarbonyl compounds) with fullerenes are summarized. The structures and stereochemistry of cycloadducts formed in these reactions are considered.

  7. Diazo compounds in the chemistry of fullerenes

    Energy Technology Data Exchange (ETDEWEB)

    Tuktarov, Airat R; Dzhemilev, Usein M [Institute of Petrochemistry and Catalysis, Russian Academy of Sciences, Ufa (Russian Federation)

    2010-09-14

    Experimental and theoretical data on the reactions of different diazo compounds (diazomethane, its derivatives, cyclic diazo compounds and diazocarbonyl compounds) with fullerenes are summarized. The structures and stereochemistry of cycloadducts formed in these reactions are considered.

  8. Method for purifying bidentate organophosphorus compounds

    International Nuclear Information System (INIS)

    Schulz, W.W.

    1977-01-01

    Bidentate organophosphorus compounds useful for extracting actinide elements from acidic nuclear waste solutions are purified of undesirable acidic impurities by contacting the compounds with ethylene glycol which preferentially extracts the impurities found in technical grade bidentate compounds

  9. Incorporation of Interfacial Intermetallic Morphology in Fracture Mechanism Map for Sn-Ag-Cu Solder Joints

    Science.gov (United States)

    Huang, Z.; Kumar, P.; Dutta, I.; Sidhu, R.; Renavikar, M.; Mahajan, R.

    2014-01-01

    A fracture mechanism map (FMM) is a powerful tool which correlates the fracture behavior of a material to its microstructural characteristics in an explicit and convenient way. In the FMM for solder joints, an effective thickness of the interfacial intermetallic compound (IMC) layer ( t eff) and the solder yield strength ( σ ys,eff) are used as abscissa and ordinate axes, respectively, as these two predominantly affect the fracture behavior of solder joints. Earlier, a definition of t eff, based on the uniform thickness of IMC ( t u) and the average height of the IMC scallops ( t s), was proposed and shown to aptly explain the fracture behavior of solder joints on Cu. This paper presents a more general definition of t eff that is more widely applicable to a range of metallizations, including Cu and electroless nickel immersion gold (ENIG). Using this new definition of t eff, mode I FMM for SAC387/Cu joints has been updated and its validity was confirmed. A preliminary FMM for SAC387/Cu joints with ENIG metallization is also presented.

  10. Extraterrestrial Organic Compounds in Meteorites

    Science.gov (United States)

    Botta, Oliver; Bada, Jeffrey L.; Meyer, Michael (Technical Monitor)

    2003-01-01

    Many organic compounds or their precursors found in meteorites originated in the interstellar or circumstellar medium and were later incorporated into planetesimals during the formation of the solar system. There they either survived intact or underwent further processing to synthesize secondary products on the meteorite parent body. The most distinct feature of CI and CM carbonaceous chondrites, two types of stony meteorites, is their high carbon content (up to 3% of weight), either in the form of carbonates or of organic compounds. The bulk of the organic carbon consists of an insoluble macromolecular material with a complex structure. Also present is a soluble organic fraction, which has been analyzed by several separation and analytical procedures. Low detection limits can be achieved by derivatization of the organic molecules with reagents that allow for analysis by gas chromatography/mass spectroscopy and high performance liquid chromatography. The CM meteorite Murchison has been found to contain more than 70 extraterrestrial amino acids and several other classes of compounds including carboxylic acids, hydroxy carboxylic acids, sulphonic and phosphonic acids, aliphatic, aromatic and polar hydrocarbons, fullerenes, heterocycles as well as carbonyl compounds, alcohols, amines and amides. The organic matter was found to be enriched in deuterium, and distinct organic compounds show isotopic enrichments of carbon and nitrogen relative to terrestrial matter.

  11. Vanadium Compounds as PTP Inhibitors

    Directory of Open Access Journals (Sweden)

    Elsa Irving

    2017-12-01

    Full Text Available Phosphotyrosine signaling is regulated by the opposing actions of protein tyrosine kinases (PTKs and protein tyrosine phosphatases (PTPs. Here we discuss the potential of vanadium derivatives as PTP enzyme inhibitors and metallotherapeutics. We describe how vanadate in the V oxidized state is thought to inhibit PTPs, thus acting as a pan-inhibitor of this enzyme superfamily. We discuss recent developments in the biological and biochemical actions of more complex vanadium derivatives, including decavanadate and in particular the growing number of oxidovanadium compounds with organic ligands. Pre-clinical studies involving these compounds are discussed in the anti-diabetic and anti-cancer contexts. Although in many cases PTP inhibition has been implicated, it is also clear that many such compounds have further biochemical effects in cells. There also remain concerns surrounding off-target toxicities and long-term use of vanadium compounds in vivo in humans, hindering their progress through clinical trials. Despite these current misgivings, interest in these chemicals continues and many believe they could still have therapeutic potential. If so, we argue that this field would benefit from greater focus on improving the delivery and tissue targeting of vanadium compounds in order to minimize off-target toxicities. This may then harness their full therapeutic potential.

  12. Microstructure and Mechanical Property of 3003 Aluminum Alloy Joint Brazed with Al-Si-Cu-Zn Filler Metal

    Directory of Open Access Journals (Sweden)

    LI Xiao-qiang

    2016-09-01

    Full Text Available Al-Si-Cu-Zn filler metal was developed to braze 3003 aluminum alloy. The microstructure and fracture surface of the joint were analyzed by XRD, SEM and EDS, and the effects of brazing temperature on microstructure and property of the joint were investigated. The results show that good joints are obtained at brazing temperature of 540-580℃ for 10min. The brazed joint consists of α(Al solid solution, θ(Al2Cu intermetallic compound, fine silicon phase and AlCuFeMn+Si phase in the central zone of brazed seam, and α(Al solid solution and element diffusion layers at both the sides of brazed seam, and the base metal. The room temperature (RT shear fracture of the joint occurs at the interface between the teeth shape α(Al in the diffusion layer and the center zone of brazed seam, which is mainly characterized as brittle cleavage. As the brazing temperature increases, α(Al solid solution crystals in the diffusion zone grow up, and the interfacial bonding of the joint is in the form of interdigitation. Brazing at 560℃ for 10min, the RT shear strength of the joint reaches the maximum value of 92.3MPa, which is about 62.7% of the base material.

  13. Joint ventures: to pursue or not to pursue?

    Science.gov (United States)

    Blaszyk, Michael D; Hill-Mischel, Jody

    2007-11-01

    Hospitals should carefully select joint venture partners. The joint venture evaluation process should involve a high-level screen of strategic opportunities. Hospitals should develop a full business plan for the joint venture.

  14. Joint refinery selenium treatability study

    International Nuclear Information System (INIS)

    Meyer, C.L.; Folwarkow, S.

    1993-01-01

    The San Francisco Regional Water Quality Control Board recently established mass limits on discharges of selenium to the San Francisco Bay from several petroleum refineries. The refineries had been working independently to develop control strategies, including both source control and treatment options, for removal of selenium from their discharges. By January 1992, over fifty different combinations of treatment technologies, wastewater streams, and pretreatment steps had been investigated to determine their effectiveness and feasibility as selenium removal processes. No treatment process studied could achieve the required mass limits without serious negative environmental consequences, such as generation of large amounts of hazardous sludge. To better facilitate the development of a feasible selenium treatment process, the six Bay Area refineries shared results of their studies and identified several technologies that, with further work, could be developed further. This additional work is currently being carried out as part of a joint selenium treatability study sponsored by the Western States Petroleum Association. A review of the previous source control and treatment studies, along with a description of the current treatability studies will be discussed

  15. The Joint COntrols Project Framework

    CERN Document Server

    González-Berges, M

    2003-01-01

    The Framework is one of the subprojects of the Joint COntrols Project (JCOP), which is collaboration between the four LHC experiments and CERN. By sharing development, this will reduce the overall effort required to build and maintain the experiment control systems. As such, the main aim of the Framework is to deliver a common set of software components, tools and guidelines that can be used by the four LHC experiments to build their control systems. Although commercial components are used wherever possible, further added value is obtained by customisation for HEP-specific applications. The supervisory layer of the Framework is based on the SCADA tool PVSS, which was selected after a detailed evaluation. This is integrated with the front-end layer via both OPC (OLE for Process Control), an industrial standard, and the CERN-developed DIM (Distributed Information Management System) protocol. Several components are already in production and being used by running fixed-target experiments at CERN as well as for th...

  16. Gulf Canada's Russian joint venture

    International Nuclear Information System (INIS)

    Motyka, D.

    1992-01-01

    After three years of evaluating prospects and negotiating with government and industry representatives, Gulf Canada established its first joint venture in the Russian Federation with Komineft, a production association from the Komi autonomous republic. Komineft has a 50% share of the venture, and the rest is shared equally between Gulf and British Gas. The operating area is at the Vozey and Upper Vozey fields in the Timan-Pechora Basin, some 1,500 km northeast of Moscow just inside the Arctic Circle. An attractive feature of the Upper Vozey project is low development costs of ca $2/bbl. In the Vozey field, the venture will set up an enhanced oil recovery demonstration project to test techniques perfected in Alberta. About 60 Canadians are involved on the project, and headquarters are in Usinsk, ca 100 km south of the oil fields. In the first half of 1992, oil production in the first phase of the venture averaged around 10,000 bbl/d and continues to increase

  17. Aksa plans polypropylene joint venture

    International Nuclear Information System (INIS)

    Alperowicz, N.

    1992-01-01

    Turkish acrylic fiber maker Aksa (Yalova), part of the Akkok textile conglomerate, is studying construction of a world-scale polypropylene (PP) plant as part of its diversification plans. The company says it is engaged in discussions with three 'multinations in the PP business' on the possibility of a joint venture. One of the firms is understood to be Amoco. Aksa is looking at three possible locations for the 100,000 m.t.-150,000 m.t./year plant: Yalova, near Istanbul, where its existing plants are located; Zonguldak, on the Black Sea coast; and within one of the existing complexes or a new site belonging to state-owned Petkim. Aksa has not yet discussed that option with Petkim, which recently received approval to build a $2.5-billion petrochemical complex. The Aksa PP plant would cost about $100 million and would use propylene from world markets. The onstream date depends on Aksa's ability to link up with a foreign partner, but it hopes to complete the unit within three years. Turkey has only one PP plant, a 65,000-m.t./year Petkim unit at Aliaga. The domestic market is currently two to three times that amount and is growing. Petkim also plans a 200,000-m.t./year PP plant as part of its new complex

  18. [Determination of joint contact area using MRI].

    Science.gov (United States)

    Yoshida, Hidenori; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji

    2009-10-20

    Elevated contact stress on the articular joints has been hypothesized to contribute to articular cartilage wear and joint pain. However, given the limitations of using contact stress and areas from human cadaver specimens to estimate articular joint stress, there is need for an in vivo method to obtain such data. Magnetic resonance imaging (MRI) has been shown to be a valid method of quantifying the human joint contact area, indicating the potential for in vivo assessment. The purpose of this study was to describe a method of quantifying the tibiofemoral joint contact area using MRI. The validity of this technique was established in porcine cadaver specimens by comparing the contact area obtained from MRI with the contact area obtained using pressure-sensitive film (PSF). In particular, we assessed the actual condition of contact by using the ratio of signal intensity of MR images of cartilage surfaces. Two fresh porcine cadaver knees were used. A custom loading apparatus was designed to apply a compressive load to the tibiofemoral joint. We measured the contact area by using MRI and PSF methods. When the ratio of signal intensity of the cartilage surface was 0.9, the error of the contact area between the MR image and PSF was about 6%. These results suggest that this MRI method may be a valuable tool in quantifying joint contact area in vivo.

  19. Determination of joint contact area using MRI

    International Nuclear Information System (INIS)

    Yoshida, Hidenori; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji

    2009-01-01

    Elevated contact stress on the articular joints has been hypothesized to contribute to articular cartilage wear and joint pain. However, given the limitations of using contact stress and areas from human cadaver specimens to estimate articular joint stress, there is need for an in vivo method to obtain such data. Magnetic resonance imaging (MRI) has been shown to be a valid method of quantifying the human joint contact area, indicating the potential for in vivo assessment. The purpose of this study was to describe a method of quantifying the tibiofemoral joint contact area using MRI. The validity of this technique was established in porcine cadaver specimens by comparing the contact area obtained from MRI with the contact area obtained using pressure-sensitive film (PSF). In particular, we assessed the actual condition of contact by using the ratio of signal intensity of MR images of cartilage surfaces. Two fresh porcine cadaver knees were used. A custom loading apparatus was designed to apply a compressive load to the tibiofemoral joint. We measured the contact area by using MRI and PSF methods. When the ratio of signal intensity of the cartilage surface was 0.9, the error of the contact area between the MR image and PSF was about 6%. These results suggest that this MRI method may be a valuable tool in quantifying joint contact area in vivo. (author)

  20. Flexible joints in structural and multibody dynamics

    Directory of Open Access Journals (Sweden)

    O. A. Bauchau

    2013-02-01

    Full Text Available Flexible joints, sometimes called bushing elements or force elements, are found in all structural and multibody dynamics codes. In their simplest form, flexible joints simply consist of sets of three linear and three torsional springs placed between two nodes of the model. For infinitesimal deformations, the selection of the lumped spring constants is an easy task, which can be based on a numerical simulation of the joint or on experimental measurements. If the joint undergoes finite deformations, identification of its stiffness characteristics is not so simple, specially if the joint is itself a complex system. When finite deformations occur, the definition of deformation measures becomes a critical issue. This paper proposes a family of tensorial deformation measures suitable for elastic bodies of finite dimension. These families are generated by two parameters that can be used to modify the constitutive behavior of the joint, while maintaining the tensorial nature of the deformation measures. Numerical results demonstrate the objectivity of the deformations measures, a feature that is not shared by the deformations measures presently used in the literature. The impact of the choice of the two parameters on the constitutive behavior of the flexible joint is also investigated.

  1. Joint made of shape memory alloy

    International Nuclear Information System (INIS)

    Amano, Kazuo; Enomoto, Kunio

    1998-01-01

    The present invention provides a joint which is less loosen even if it is used under a circumference undergoing heat cycles such as in a nuclear power plant. Namely, a liner shape has a structure different between the right-to-left, which is different from existent right and left symmetrical shape. A groove is formed on the side of pipeline to be connected, and upon joint connection, the liner is pushed into the groove formed on the pipeline to connect them by the force caused upon transformation of the shape memory alloy. In the joint having such a structure, the clamping force of the joint is less reduced by the effects of heat cycles. Even when the clamping force is reduced by some or other causes, the joint is not dropped off from the pipeline. Even when the joint made of a shape memory alloy of a type using a liner is used as a joint for connecting longitudinal pipelines of a nuclear power plant, the reliability and the safety can be maintained. (I.S.)

  2. Real-time visualization of joint cavitation.

    Directory of Open Access Journals (Sweden)

    Gregory N Kawchuk

    Full Text Available Cracking sounds emitted from human synovial joints have been attributed historically to the sudden collapse of a cavitation bubble formed as articular surfaces are separated. Unfortunately, bubble collapse as the source of joint cracking is inconsistent with many physical phenomena that define the joint cracking phenomenon. Here we present direct evidence from real-time magnetic resonance imaging that the mechanism of joint cracking is related to cavity formation rather than bubble collapse. In this study, ten metacarpophalangeal joints were studied by inserting the finger of interest into a flexible tube tightened around a length of cable used to provide long-axis traction. Before and after traction, static 3D T1-weighted magnetic resonance images were acquired. During traction, rapid cine magnetic resonance images were obtained from the joint midline at a rate of 3.2 frames per second until the cracking event occurred. As traction forces increased, real-time cine magnetic resonance imaging demonstrated rapid cavity inception at the time of joint separation and sound production after which the resulting cavity remained visible. Our results offer direct experimental evidence that joint cracking is associated with cavity inception rather than collapse of a pre-existing bubble. These observations are consistent with tribonucleation, a known process where opposing surfaces resist separation until a critical point where they then separate rapidly creating sustained gas cavities. Observed previously in vitro, this is the first in-vivo macroscopic demonstration of tribonucleation and as such, provides a new theoretical framework to investigate health outcomes associated with joint cracking.

  3. SEURAT-1 liver gold reference compounds: a mechanism-based review.

    Science.gov (United States)

    Jennings, Paul; Schwarz, Michael; Landesmann, Brigitte; Maggioni, Silvia; Goumenou, Marina; Bower, David; Leonard, Martin O; Wiseman, Jeffrey S

    2014-12-01

    There is an urgent need for the development of alternative methods to replace animal testing for the prediction of repeat dose chemical toxicity. To address this need, the European Commission and Cosmetics Europe have jointly funded a research program for 'Safety Evaluation Ultimately Replacing Animal Testing.' The goal of this program was the development of in vitro cellular systems and associated computational capabilities for the prediction of hepatic, cardiac, renal, neuronal, muscle, and skin toxicities. An essential component of this effort is the choice of appropriate reference compounds that can be used in the development and validation of assays. In this review, we focus on the selection of reference compounds for liver pathologies in the broad categories of cytotoxicity and lipid disorders. Mitochondrial impairment, oxidative stress, and apoptosis are considered under the category of cytotoxicity, while steatosis, cholestasis, and phospholipidosis are considered under the category of lipid dysregulation. We focused on four compound classes capable of initiating such events, i.e., chemically reactive compounds, compounds with specific cellular targets, compounds that modulate lipid regulatory networks, and compounds that disrupt the plasma membrane. We describe the molecular mechanisms of these compounds and the cellular response networks which they elicit. This information will be helpful to both improve our understanding of mode of action and help in the selection of appropriate mechanistic biomarkers, allowing us to progress the development of animal-free models with improved predictivity to the human situation.

  4. Radiology of disorders of the sacroiliac joints

    International Nuclear Information System (INIS)

    Resnik, C.S.; Resnick, D.

    1985-01-01

    Many disorders can lead to radiological abnormalities of the sacroiliac joints. Some present a characteristic appearance, while others may be diagnosed by analyzing both the appearance and the distribution of findings. Computed tomography provides excellent visualization of the sacroiliac joints and can be helpful in the evaluation of articular disorders as well as pelvic trauma and neoplasms. Radionuclide scanning of bone can also be used to evaluate the sacroiliac joints, particularly if the two sides are compared with the assistance of computer-generated activity counts. This article describes the radiological features of these various disorders that often allow an exact diagnosis to be made

  5. Synovial Lipomatosis of the Glenohumeral Joint

    Directory of Open Access Journals (Sweden)

    Shaul Beyth

    2016-01-01

    Full Text Available Synovial lipomatosis (also known as lipoma arborescens is a rare and benign lesion affecting synovium-lined cavities. It is characterized by hyperplasia of mature fat tissue in the subsynovial layer. Although the most commonly affected site is the knee joint, rarely additional locations such as tendon sheath and other joints are involved. We present a case of synovial lipomatosis of the glenohumeral joint in a 44-year-old man. The clinical data radiological studies and histopathologic results are described, as well as a review of the current literature.

  6. Traumatic injuries of the temporomandibular joint

    International Nuclear Information System (INIS)

    Puig, S.; Krestan, C.; Lomoschitz, F.; Robinson, S.; Glaser, C.; Staudenherz, A.

    2001-01-01

    Injuries of the temporomandibular joint are mostly due to injuries or fractures of the mandibular condyle. Fractures of the skull base involving the temporomandibular joint are rare. Classification of fractures refers to their anatomical positions and the presence or absence of a luxation. Further, it is important whether the fracture is intra- or extra-capsular. The primary imaging method should be orthopantomography. As for therapy planning, especially surgery, also evaluation of soft tissue is necessary, computed tomography is the imaging method of choice. For diagnosis of complications or internal derangement of the temporomandibular joint, magnetic resonance imaging is to be recommended. (orig.) [de

  7. Joint balance handling in the Nordic Countries

    International Nuclear Information System (INIS)

    2005-01-01

    In September 2002 Nordel introduced new principles for disposing of regulation power for balancing production and consumption of electricity. The new principles imply that the regulation power in the joint Nordic power system is better utilized, and that the settlement of imbalances between the countries follows joint rules. The settlement of imbalances in the individual countries follows different principles but Nordel is looking into the possibilities of a harmonization. EU's most recent draft of a strategy report on development of the power market points among other things towards a joint regulation power market as a tool against misuse of market power. (BA)

  8. Functional MR imaging of the patellofemoral joint

    International Nuclear Information System (INIS)

    Muhle, C.; Brossmann, J.; Heller, M.

    1995-01-01

    Conventional X-ray examinations of the patellofemoral joint in 30 , 60 and 90 of knee flexion demonstrate the position of the patella. On the other hand, they have been shown to be insufficient for the diagnosis of patellofemoral maltracking in the critical range between 30 of flexion and full extension. Motion-triggered and ultrafast MRI offer new possibilities for functional diagnosis of the patellofemoral joint under active knee motion. Functional MRI of the patellofemoral joint is suggested as an alternative to arthroscopy, particularly in patients with anterior knee pain or suspected patellar maltracking. (orig.) [de

  9. Radiological evaluation of the acromioclavicular joint

    International Nuclear Information System (INIS)

    Vaeaetaeinen, U.; Maekelae, A.; Pirinen, A.

    1991-01-01

    X-ray measurement of the acromioclavicular (AC) joint may cause difficulties because of different projections and the lack of a reproducible measurement. In order to find the ideal measurement to estimate the state of the AC joint, 28 healthy adult volunteers were X-rayed. The least vulnerable measurement for errors in projection was the distance between the coracoid process and the upper part of the clavicle. The effect of stress was evaluated; the range of normal AC joint laxity was determined as 3 mm. (orig.)

  10. Radiological evaluation of the acromioclavicular joint

    Energy Technology Data Exchange (ETDEWEB)

    Vaeaetaeinen, U.; Maekelae, A. (Kuopio Univ. Central Hospital (Finland). Dept. of Surgery); Pirinen, A. (Kuopio Univ. Central Hospital (Finland). Dept. of Radiology)

    1991-02-01

    X-ray measurement of the acromioclavicular (AC) joint may cause difficulties because of different projections and the lack of a reproducible measurement. In order to find the ideal measurement to estimate the state of the AC joint, 28 healthy adult volunteers were X-rayed. The least vulnerable measurement for errors in projection was the distance between the coracoid process and the upper part of the clavicle. The effect of stress was evaluated; the range of normal AC joint laxity was determined as 3 mm. (orig.).

  11. Knee joint vibroarthrographic signal processing and analysis

    CERN Document Server

    Wu, Yunfeng

    2015-01-01

    This book presents the cutting-edge technologies of knee joint vibroarthrographic signal analysis for the screening and detection of knee joint injuries. It describes a number of effective computer-aided methods for analysis of the nonlinear and nonstationary biomedical signals generated by complex physiological mechanics. This book also introduces several popular machine learning and pattern recognition algorithms for biomedical signal classifications. The book is well-suited for all researchers looking to better understand knee joint biomechanics and the advanced technology for vibration arthrometry. Dr. Yunfeng Wu is an Associate Professor at the School of Information Science and Technology, Xiamen University, Xiamen, Fujian, China.

  12. Can symptomatic acromioclavicular joints be differentiated from asymptomatic acromioclavicular joints on 3-T MR imaging?

    Science.gov (United States)

    Choo, Hye Jung; Lee, Sun Joo; Kim, Jung Han; Cha, Seong Sook; Park, Young Mi; Park, Ji Sung; Lee, Jun Woo; Oh, Minkyung

    2013-04-01

    To evaluate retrospectively whether symptomatic acromioclavicular joints can be differentiated from asymptomatic acromioclavicular joints on 3-T MR imaging. This study included 146 patients who underwent physical examination of acromioclavicular joints and 3-T MR imaging of the shoulder. Among them, 67 patients showing positive results on physical examination were assigned to the symptomatic group, whereas 79 showing negative results were assigned to the asymptomatic group. The following MR findings were compared between the symptomatic and asymptomatic groups: presence of osteophytes, articular surface irregularity, subchondral cysts, acromioclavicular joint fluid, subacromial fluid, subacromial bony spurs, joint capsular distension, bone edema, intraarticular enhancement, periarticular enhancement, superior and inferior joint capsular distension degree, and joint capsular thickness. The patients were subsequently divided into groups based on age (younger, older) and the method of MR arthrography (direct MR arthrography, indirect MR arthrography), and all the MR findings in each subgroup were reanalyzed. The meaningful cutoff value of each significant continuous variable was calculated using receiver operating characteristic analysis. The degree of superior capsular distension was the only significant MR finding of symptomatic acromioclavicular joints and its meaningful cutoff value was 2.1mm. After subgroup analyses, this variable was significant in the older age group and indirect MR arthrography group. On 3-T MR imaging, the degree of superior joint capsular distension might be a predictable MR finding in the diagnosis of symptomatic acromioclavicular joints. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  13. A computational model for three-dimensional jointed media with a single joint set

    International Nuclear Information System (INIS)

    Koteras, J.R.

    1994-02-01

    This report describes a three-dimensional model for jointed rock or other media with a single set of joints. The joint set consists of evenly spaced joint planes. The normal joint response is nonlinear elastic and is based on a rational polynomial. Joint shear stress is treated as being linear elastic in the shear stress versus slip displacement before attaining a critical stress level governed by a Mohr-Coulomb faction criterion. The three-dimensional model represents an extension of a two-dimensional, multi-joint model that has been in use for several years. Although most of the concepts in the two-dimensional model translate in a straightforward manner to three dimensions, the concept of slip on the joint planes becomes more complex in three dimensions. While slip in two dimensions can be treated as a scalar quantity, it must be treated as a vector in the joint plane in three dimensions. For the three-dimensional model proposed here, the slip direction is assumed to be the direction of maximum principal strain in the joint plane. Five test problems are presented to verify the correctness of the computational implementation of the model

  14. The structures of binary compounds

    CERN Document Server

    Hafner, J; Jensen, WB; Majewski, JA; Mathis, K; Villars, P; Vogl, P; de Boer, FR

    1990-01-01

    - Up-to-date compilation of the experimental data on the structures of binary compounds by Villars and colleagues. - Coloured structure maps which order the compounds into their respective structural domains and present for the first time the local co-ordination polyhedra for the 150 most frequently occurring structure types, pedagogically very helpful and useful in the search for new materials with a required crystal structure. - Crystal co-ordination formulas: a flexible notation for the interpretation of solid-state structures by chemist Bill Jensen. - Recent important advances in unders

  15. Catalytic applications of niobium compounds

    International Nuclear Information System (INIS)

    Wright, C.J.; England, W.A.

    1984-01-01

    This article examines the potential uses of niobium, and its compounds, as catalysts in chemical processing. The word potential is deliberately chosen because in 1978 none of the world's twenty-five major catalysts (1) contained niobium. On the other hand, catalysts containing molybdenum and vanadium, neighbors of niobium in the periodic table, realized over 80 x 10 6 of sales in that same year. At the same time many of the patents for niobium catalysts cover applications in which niobium improves the activity of, or substitutes for, molybdenum based compounds. With favorable cost differentials and improvements in understanding, niobium may be able to replace molybdenum in some its traditional uses

  16. Cytotoxic Compounds from Aloe megalacantha

    Directory of Open Access Journals (Sweden)

    Negera Abdissa

    2017-07-01

    Full Text Available Phytochemical investigation of the ethyl acetate extract of the roots of Aloe megalacantha led to the isolation of four new natural products—1,8-dimethoxynepodinol (1, aloesaponarin III (2, 10-O-methylchrysalodin (3 and methyl-26-O-feruloyl-oxyhexacosanate (4—along with ten known compounds. All purified metabolites were characterized by NMR, mass spectrometric analyses and comparison with literature data. The isolates were evaluated for their cytotoxic activity against a human cervix carcinoma cell line KB-3-1 and some of them exhibited good activity, with aloesaponarin II (IC50 = 0.98 µM being the most active compound.

  17. Antiprotozoal compounds from Asparagus africanus

    DEFF Research Database (Denmark)

    Oketch-Rabah, H A; Dossaji, S F; Christensen, S B

    1997-01-01

    Two antiprotozoal compounds have been isolated from the roots of Asparagus africanus Lam. (Liliaceae), a new sapogenin, 2 beta, 12 alpha-dihydroxy-(25R)-spirosta-4,7-dien-3-one (1), which was named muzanzagenin, and the lignan (+)-nyasol (2), (Z)-(+)-4,4'-(3-ethenyl-1-propene-1,3-diyl)-bisphenol.......Two antiprotozoal compounds have been isolated from the roots of Asparagus africanus Lam. (Liliaceae), a new sapogenin, 2 beta, 12 alpha-dihydroxy-(25R)-spirosta-4,7-dien-3-one (1), which was named muzanzagenin, and the lignan (+)-nyasol (2), (Z)-(+)-4,4'-(3-ethenyl-1-propene-1,3-diyl...

  18. Lower limb joint work and joint work contribution during downhill and uphill walking at different inclinations.

    Science.gov (United States)

    Alexander, Nathalie; Strutzenberger, Gerda; Ameshofer, Lisa Maria; Schwameder, Hermann

    2017-08-16

    Work performance and individual joint contribution to total work are important information for creating training protocols, but were not assessed so far for sloped walking. Therefore, the purpose of this study was to analyze lower limb joint work and joint contribution of the hip, knee and ankle to total lower limb work during sloped walking in a healthy population. Eighteen male participants (27.0±4.7yrs, 1.80±0.05m, 74.5±8.2kg) walked on an instrumented ramp at inclination angles of 0°, ±6°, ±12° and ±18° at 1.1m/s. Kinematic and kinetic data were captured using a motion-capture system (Vicon) and two force plates (AMTI). Joint power curves, joint work (positive, negative, absolute) and each joint's contribution to total lower limb work were analyzed throughout the stance phase using an ANOVA with repeated measures. With increasing inclination positive joint work increased for the ankle and hip joint and in total during uphill walking. Negative joint work increased for each joint and in total work during downhill walking. Absolute work was increased during both uphill (all joints) and downhill (ankle & knee) walking. Knee joint contribution to total negative and absolute work increased during downhill walking while hip and ankle contributions decreased. This study identified, that, when switching from level to a 6° and from 6° to a 12° inclination the gain of individual joint work is more pronounced compared to switching from 12° to an 18° inclination. The results might be used for training recommendations and specific training intervention with respect to sloped walking. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Restructuring to Achieve Joint Engineer Integration and Transformation

    National Research Council Canada - National Science Library

    Kelly, Paul

    2003-01-01

    .... Increased joint engineer operations, including new homeland defense support requirements, transformation of the joint force, and the growing need for efficient use of scarce engineer resources...

  20. FY 2002 End of Year Report (Joint Advanced Warfighting Program)

    National Research Council Canada - National Science Library

    Gold, Theodore

    2003-01-01

    ...) I Experiment and joint urban operations. However, other JAWP activities are described, for example, metrics for transformation, continuous joint experimentation, commercial-off-the-shelf (COTS...

  1. Compound

    Indian Academy of Sciences (India)

    Selen Bilgea,*, Zeynel Kılıça, Zeliha Hayvalıa, Tuncer Hökelekb and Serap Safranb. aDepartment of Chemistry, Faculty of Science, Ankara University, Tandoğan, Ankara 06100, Turkey. bDepartment of Physics, Hacettepe University, Beytepe, Ankara 06800, Turkey. e-mail: sbilge@science.ankara.edu.tr. Contents: Tables.

  2. An experimental study of hafting adhesives and the implications for compound tool technology.

    Science.gov (United States)

    Zipkin, Andrew M; Wagner, Mark; McGrath, Kate; Brooks, Alison S; Lucas, Peter W

    2014-01-01

    Experimental studies of hafting adhesives and modifications to compound tool components can demonstrate the extent to which human ancestors understood and exploited material properties only formally defined by science within the last century. Discoveries of Stone Age hafting adhesives at archaeological sites in Europe, the Middle East, and Africa have spurred experiments that sought to replicate or create models of such adhesives. Most of these studies, however, have been actualistic in design, focusing on replicating ancient applications of adhesive technology. In contrast, this study tested several glues based on Acacia resin within a materials science framework to better understand the effect of each adhesive ingredient on compound tool durability. Using an overlap joint as a model for a compound tool, adhesives formulated with loading agents from a range of particle sizes and mineral compositions were tested for toughness on smooth and rough substrates. Our results indicated that overlap joint toughness is significantly increased by using a roughened joint surface. Contrary to some previous studies, there was no evidence that particle size diversity in a loading agent improved adhesive effectiveness. Generally, glues containing quartz or ochre loading agents in the silt and clay-sized particle class yielded the toughest overlap joints, with the effect of particle size found to be more significant for rough rather than smooth substrate joints. Additionally, no particular ochre mineral or mineral mixture was found to be a clearly superior loading agent. These two points taken together suggest that Paleolithic use of ochre-loaded adhesives and the criteria used to select ochres for this purpose may have been mediated by visual and symbolic considerations rather than purely functional concerns.

  3. Brazing technology of Ti alloy/stainless steel dissimilar metal joint at system integrated modular advanced reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Sang Chul; Kim, Sung Ho; Kim, Yong Wan; Kim, Jong In

    2001-02-01

    For the technoldogy development of brazing Ti alloy to stainless steel joints used at SMART, the status of brazing technology development, brazing processes, and the brazing technology of Ti alloy and stainless steel are reviewed. Because fusion welding process cannot be applied due to the formation of intermetallic compounds in the weld metal, brazing joint was selected at the design. The joint part is assembled with a thread composed with male part of Ti alloy tube and female part of stainless tube. The gap in the thread will be filled with brazing filler metal. However, brittle Ti-Fe intermetallic compounds are formed at the surface of stainless steel through the diffusion of Ti at the melt. Brazing conditions should be set-up to reduce the formation of intermetallic compounds. For that, 3 kinds of Ag filler metals were selected as the candidates and heating will be done with induction and electric furnaces. Through measuring of joint strength according to the control of pre- and post-braze treatment, heating rate and heating time, optimal brazing method will be fixed. To qualify the brazing procedure and performance and to check defects in final product, the inspection plan will be established according to the req2wuirements of AWS and ASME.

  4. Brazing technology of Ti alloy/stainless steel dissimilar metal joint at system integrated modular advanced reactor

    International Nuclear Information System (INIS)

    Kwon, Sang Chul; Kim, Sung Ho; Kim, Yong Wan; Kim, Jong In

    2001-02-01

    For the technoldogy development of brazing Ti alloy to stainless steel joints used at SMART, the status of brazing technology development, brazing processes, and the brazing technology of Ti alloy and stainless steel are reviewed. Because fusion welding process cannot be applied due to the formation of intermetallic compounds in the weld metal, brazing joint was selected at the design. The joint part is assembled with a thread composed with male part of Ti alloy tube and female part of stainless tube. The gap in the thread will be filled with brazing filler metal. However, brittle Ti-Fe intermetallic compounds are formed at the surface of stainless steel through the diffusion of Ti at the melt. Brazing conditions should be set-up to reduce the formation of intermetallic compounds. For that, 3 kinds of Ag filler metals were selected as the candidates and heating will be done with induction and electric furnaces. Through measuring of joint strength according to the control of pre- and post-braze treatment, heating rate and heating time, optimal brazing method will be fixed. To qualify the brazing procedure and performance and to check defects in final product, the inspection plan will be established according to the req2wuirements of AWS and ASME

  5. Methodological problems of sacroiliac joint scintigraphy

    International Nuclear Information System (INIS)

    Schoerner, W.; Haubold, U.

    1981-01-01

    Bone scintigraphy of the sacroiliac joints and the lumbar spine was performed in 35 patients with ankylosing spondylitis and 30 control subjects. The scans were evaluated by qualitative and quantitative assessment. The sacroiliac/sacrum ratio (index ISG/sacrum), the sacroiliac/lumbar spine ratio (index ISG/LWS), and the left sacroiliac joint/right sacroiliac joint ratio (index li. ISG/re. ISG) were calculated. The visual interpretation of colour scans proved to be unreliable. The index ISG/sacrum was more sensitive than the index ISG/LWS. The index li. ISG/re. ISG was helpful as an additional criterion. When digital sacroiliac joint scintigraphy is well standardized it can be considered as a useful technique in early diagnosis of ankylosing spondylitis. (orig.) [de

  6. Radiosynoviorthesis in osteoarthritis of finger joints

    International Nuclear Information System (INIS)

    Moedder, G.

    2006-01-01

    This is an overview about osteoarthritis of the finger joints. The scientific publications according to the therapy of this disease by means of radiosynoviorthesis are presented, comparing the results in rheumatoid arthritis. Additionally own experience and results are reported. (orig.)

  7. Migratory Bird Joint Ventures of New Mexico

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — A joint venture is a self-directed partnership of agencies, organizations, corporations, tribes, or individuals that has formally accepted the responsibility of...

  8. Functionally Graded Adhesives for Composite Joints

    Science.gov (United States)

    Stapleton, Scott E.; Waas, Anthony M.; Arnold, Steven M.

    2012-01-01

    Adhesives with functionally graded material properties are being considered for use in adhesively bonded joints to reduce the peel stress concentrations located near adherend discontinuities. Several practical concerns impede the actual use of such adhesives. These include increased manufacturing complications, alterations to the grading due to adhesive flow during manufacturing, and whether changing the loading conditions significantly impact the effectiveness of the grading. An analytical study is conducted to address these three concerns. An enhanced joint finite element, which uses an analytical formulation to obtain exact shape functions, is used to model the joint. Furthermore, proof of concept testing is conducted to show the potential advantages of functionally graded adhesives. In this study, grading is achieved by strategically placing glass beads within the adhesive layer at different densities along the joint.

  9. Candida infection of a prosthetic shoulder joint

    Energy Technology Data Exchange (ETDEWEB)

    Lichtman, E.A.

    1983-09-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole.

  10. The Evolution of the Joint ATO Cycle

    National Research Council Canada - National Science Library

    Winkler, Robert P

    2006-01-01

    .... The paper shows that the command and control process in current Joint Doctrine evolved over time to with particular attention paid to meeting the land component objectives using AirLand battle doctrine...

  11. Osseous temporomandibular joint abnormalities in rheumatic disease

    International Nuclear Information System (INIS)

    Larheim, T.A.; Kolbenstvedt, A.; Rikshospitalet, Oslo

    1990-01-01

    Computed tomography (CT) of the temporomandibular joint (TMJ) was compared with hypocycloidal tomography in 30 joints of 15 adults with rheumatic disease. CT included 1.5 mm thick axial scans (at 1.0 mm intervals) with reformatted oblique sagittal and oblique coronal sections. Multisection (at 2.0 mm intervals) tomography included oblique sagittal and occasionally, oblique coronal sections. CT demonstrated bone abnormalities in 21 and tomography in 20 joints, indicating high agreement between the imaging modalities regarding number of abnormal TMJs. Bone structures were, however, better visualized by multiplanar CT due to superior contrast and spatial resolution particularly in the most lateral and medial parts of the joint, indicating superiority of CT for depicting subtle bony TMJ abnormalities in patients with rheumatic disease. (orig.)

  12. Use of expansion joints in power stations

    International Nuclear Information System (INIS)

    Birker; Rommerswinkel.

    1976-01-01

    The paper discusses the mode of action of different systems of expansion joints. Special regard is given to the problems of expansion of pipelines of high rated diameter as employed in today's large power plant turbines. Due to the limited space available, the important role of the spring rate of the bellows for the reaction forces and moments acting on the connection points is pointed out. Apart from this details are given on the fabrication and materials selection of expansion joint bellows, and problems are discussed which arise in connection with the mechanical or hydraulic deformation of bellows with one or more walls. The non-destructive methods now in use for the testing of expansion pipe joints are mentioned along with experiments to test their behaviour under changing loads. The paper concludes on some remarks concerning proper transport, storage and installation of expansion pipe joints. (orig./AK) [de

  13. Distal radioulnar joint: functional anatomy, including pathomechanics.

    Science.gov (United States)

    Haugstvedt, J R; Langer, M F; Berger, R A

    2017-05-01

    The distal radioulnar joint allows the human to rotate the forearm to place the hand in a desired position to perform different tasks, without interfering with the grasping function of the hand. The ulna is the stable part of the forearm around which the radius rotates; the stability of the distal radioulnar joint is provided by the interaction between ligaments, muscles and bones. The stabilizing structures are the triangular fibrocartilage complex, the ulnocarpal ligament complex, the extensor carpi ulnaris tendon and tendon sheath, the pronator quadratus, the interosseous membrane and ligament, the bone itself and the joint capsule. The purpose of this review article is to present and illustrate the current understanding of the functional anatomy and pathomechanics of this joint.

  14. ADOLESCENT CHONDROLYSIS OF THE mp JOINT*

    African Journals Online (AJOL)

    1971-02-20

    Feb 20, 1971 ... slight reduction of joint space and osteophyte formation at the capital margin ... ring and irregularity of the subchondral line and an increase of CE angle, .... Unfortunately histological examination was not carried out. As the hip ...

  15. NATO Joint Medical Support - Reality and Vision

    National Research Council Canada - National Science Library

    Roedig, Erich

    2004-01-01

    .... Multinational solutions to medical support were not considered necessary or practical. The new NATO force structures and strategic concepts emphasise mobility, interoperability, sustainability, jointness and multinationality; i.e...

  16. Improved bridge joint materials and design details.

    Science.gov (United States)

    2017-06-01

    Expansion joints accommodate bridge movements that result from factors such as thermal expansion and contraction, concrete shrinkage, creep effects, live loading, settlement of the foundation and substructure, and environmental stressors. Expansion j...

  17. Joint Typhoon Warning Center (JTWC) Storm Wallets

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Joint Typhoon Warning Center (JTWC) is responsible for typhoon forecasts and warnings for the Western Pacific and Indian Ocean basins. After each storm, the JTWC...

  18. Candida infection of a prosthetic shoulder joint

    International Nuclear Information System (INIS)

    Lichtman, E.A.; Veterans Administration Medical Center, New York

    1983-01-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole. (orig.)

  19. Nano-Engineered Structural Joints, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A versatile class of high-performance structural joints is proposed where massive interatomic bonds over the large surface areas of nanostructured surfaces...

  20. Evolution of the uranium joint venture

    International Nuclear Information System (INIS)

    Bloomenthal, H.S.

    1976-01-01

    This paper concentrates on the economic realities of the joint venture in order to anticipate the basic problems that will be encountered so as to permit legislating by contrast how the problems are to be handled as between the parties

  1. The Multinational Logistics Joint Task Force (MLJTF)

    National Research Council Canada - National Science Library

    Higginbotham, Matthew T

    2007-01-01

    In this monograph, by analyzing the UN, NATO and the US Army's evolving Modular Logistics Doctrine, the author integrates the key areas from each doctrine into a multinational logistics joint task force (MLJTF) organization...

  2. Strategic Mobility 21 Joint Sea Based Logistics

    National Research Council Canada - National Science Library

    Mallon, Lawrence G

    2008-01-01

    ...-be requirements. The objective of the SM2l-JDDSP sea based logistics architecture is to support the timely distribution of the right classes of supply in sufficient quantities to allow sustained joint combat operations...

  3. Control of compliant anthropomimetic robot joint

    Directory of Open Access Journals (Sweden)

    Svetozarević Bratislav

    2011-01-01

    Full Text Available In this paper we propose a control strategy for a robot joint which fully mimics the typical human joint structure. The joint drive is based on two actuators (dc motors, agonist and antagonist, acting through compliant tendons and forming a nonlinear multi-input multi-output (MIMO system. At any time, we consider one actuator, the puller, as being responsible for motion control, while the role of the other is to keep its tendon force at some appropriate low level. This human-like and energetically efficient approach requires the control of 'switching', or exchanging roles between actuators. Moreover, an algorithm based on adaptive force reference is used to solve a problem of slacken tendons during the switching and to increase the energy efficiency. This approach was developed and evaluated on increasingly complex robot joint configurations, starting with simple and noncompliant system, and finishing with nonlinear and compliant system.

  4. Joint shape segmentation with linear programming

    KAUST Repository

    Huang, Qixing; Koltun, Vladlen; Guibas, Leonidas

    2011-01-01

    program is solved via a linear programming relaxation, using a block coordinate descent procedure that makes the optimization feasible for large databases. We evaluate the presented approach on the Princeton segmentation benchmark and show that joint shape

  5. Design of artificial human joints & organs

    CERN Document Server

    Pal, Subrata

    2013-01-01

    This book covers the design science and methodology of artificial joints and organs.  It presents the mechanical characterization of the hard and soft tissues as well as the viscoelastic properties of the tissue.

  6. Radiodiagnostics of the temporomandibular joint of disorders

    International Nuclear Information System (INIS)

    Ondrasovicova, J.; Jenca, A.

    2008-01-01

    Temporomandibularis disorders have a multifactorial etiology with very variable clinical symptoms. On the X-ray image can see the configuration of the joint structures correctly or TMJ disorders ( luxation, subluxation, arthrosis). (authors)

  7. Joint Training of Deep Boltzmann Machines

    OpenAIRE

    Goodfellow, Ian; Courville, Aaron; Bengio, Yoshua

    2012-01-01

    We introduce a new method for training deep Boltzmann machines jointly. Prior methods require an initial learning pass that trains the deep Boltzmann machine greedily, one layer at a time, or do not perform well on classifi- cation tasks.

  8. Scintigraphic presentation of hip joint synovial chondromatosis

    Energy Technology Data Exchange (ETDEWEB)

    Zwas, S T; Friedman, B; Nerubay, J

    1988-09-01

    A case of hip joint synovial chondromatosis with an unusual scintigraphic pattern is described. This pattern was suggestive of a hip joint destructive reactive articular process or late manifestations of avascular necrosis of the femoral head. Concurrent radiographs were normal, as were laboratory investigations. Follow-up radiographs six months later showed radiolucencies and erosive bone changes in the diseased joint. Surgical and histopathological findings revealed well developed hip synovial chondromatosis (HSC) with thickened synovium and large, loose, cartilaginous bodies occupying and widening the tightened joint space, with destructive secondary juxta articular pressure and bone erosions. This and other scintigraphic patterns in HSC, and the differential diagnosis of the findings in patients with painful hip presentations are discussed.

  9. DOE and NASA joint Dark Energy mission

    CERN Multimedia

    2003-01-01

    "DOE and NASA announced their plan for a Joint Dark Energy Mission (JDEM) on October 23, 2003, at the NASA Office of Space Science Structure and Evolution of the Universe Subcommittee (SEUS) meeting" (1 paragraph).

  10. Deterioration of jointed Portland cement concrete pavements.

    Science.gov (United States)

    1975-01-01

    Information has been gathered regarding the performance of more than 400 lane-miles of jointed PCC interstate pavements located in five construction districts in Virginia. The factors causing pavement deterioration have been identified, the processes...

  11. Bacterial degradation of fluorinated compounds

    NARCIS (Netherlands)

    Ferreira, Maria Isabel Martins

    2007-01-01

    Fluorine was produced for the first time by Henri Moissan in 1886, for which he received the Nobel Prize in chemistry in 1906. The unique properties of fluorine have led to the development of fluorine chemistry and numerous synthetic fluorinated compounds have been prepared and tested for different

  12. Moessbauer spectroscopy in neptunium compounds

    Energy Technology Data Exchange (ETDEWEB)

    Nakamoto, Tadahiro; Nakada, Masami; Masaki, Nobuyuki; Saeki, Masakatsu [Japan Atomic Energy Research Inst., Tokyo (Japan)

    1997-03-01

    Moessbauer effects are observable in seven elements of actinides from {sup 232}Th to {sup 247}Cm and Moesbauer spectra have been investigated mainly with {sup 237}Np and {sup 238}U for the reasons of availability and cost of materials. This report describes the fundamental characteristics of Moessbauer spectra of {sup 237}Np and the correlation between the isomer shift and the coordination number of Np(V) compounds. The isomer shifts of Np(V) compounds had a tendency to increase as an increase of coordination number and the isomer shifts of Np(V) compounds showed broad distribution as well as those of Np(VI) but {delta} values of the compounds with the same coordination number were distributed in a narrow range. The {delta} values of Np(VI) complexes with O{sub x} donor set suggest that the Np atom in its hydroxide (NpO{sub 2}(OH){center_dot}4H{sub 2}O)might have pentagonal bipyramidal structure and at least, pentagonal and hexagonal bipyramidal structures might coexist in its acetate and benzoate. Really, such coexistence has been demonstrated in its nitrate, (NpO{sub 2}){sub 2}(NO{sub 3}){sub 2}{center_dot}5H{sub 2}O. (M.N.)

  13. Antifouling Compounds from Marine Macroalgae.

    Science.gov (United States)

    Dahms, Hans Uwe; Dobretsov, Sergey

    2017-08-28

    Marine macroalgae produce a wide variety of biologically-active metabolites that have been developed into commercial products, such as antibiotics, immunosuppressive, anti-inflammatory, cytotoxic agents, and cosmetic products. Many marine algae remain clean over longer periods of time, suggesting their strong antifouling potential. Isolation of biogenic compounds and the determination of their structure could provide leads for the development of environmentally-friendly antifouling paints. Isolated substances with potent antifouling activity belong to fatty acids, lipopeptides, amides, alkaloids, lactones, steroids, terpenoids, and pyrroles. It is unclear as yet to what extent symbiotic microorganisms are involved in the synthesis of these compounds. Algal secondary metabolites have the potential to be produced commercially using genetic and metabolic engineering techniques. This review provides an overview of publications from 2010 to February 2017 about antifouling activity of green, brown, and red algae. Some researchers were focusing on antifouling compounds of brown macroalgae, while metabolites of green algae received less attention. Several studies tested antifouling activity against bacteria, microalgae and invertebrates, but in only a few studies was the quorum sensing inhibitory activity of marine macroalgae tested. Rarely, antifouling compounds from macroalgae were isolated and tested in an ecologically-relevant way.

  14. Students' Categorizations of Organic Compounds

    Science.gov (United States)

    Domin, Daniel S.; Al-Masum, Mohammad; Mensah, John

    2008-01-01

    Categorization is a fundamental psychological ability necessary for problem solving and many other higher-level cognitive tasks. In organic chemistry, students must establish groupings of different chemical compounds in order not only to solve problems, but also to understand course content. Classic models of categorization emphasize similarity as…

  15. Compound Cuing in Free Recall

    Science.gov (United States)

    Lohnas, Lynn J.; Kahana, Michael J.

    2014-01-01

    According to the retrieved context theory of episodic memory, the cue for recall of an item is a weighted sum of recently activated cognitive states, including previously recalled and studied items as well as their associations. We show that this theory predicts there should be compound cuing in free recall. Specifically, the temporal contiguity…

  16. First flush of dissolved compounds

    DEFF Research Database (Denmark)

    Krebs, P.; Holzer, P.; Huisman, J.L.

    1999-01-01

    . It is known that since the wave celerity is higher than the flow velocity of the water, the increase of flow rate induced through rain runoff is recognised earlier at a certain downstream section of the combined sewer than the concentration increase of typical rain-water compounds originating from surface...

  17. Labelled compounds for agrochemical residue studies in developing countries

    International Nuclear Information System (INIS)

    1977-01-01

    Potential applications of stable and radioactive isotopic tracers for assessing undesirable contaminants in agriculture, fisheries and food are discussed as related to developing countries. Sources and types of residues are considered, and their local implications; also, the availability of suitably labelled compounds, including possible international cooperation to facilitate more centralized and economic preparation, and the distribution of labelled intermediates and compounds for use by local scientists. The provision of training courses and their syllabus are reviewed. Experience in the Joint FAO/IAEA chemical residue and pollution programme has indicated a need for longer-lived radioisotopically labelled pesticides (insecticides, acaricides, fungicides, herbicides, fumigants, etc.) for studying their behaviour. 15 N-, 13 C- or 2 H-labelled fertilizers and fertilizer additives such as nitrification inhibitors will shortly be needed, for studying the behaviour of fertilizer nitrogen residues, and their regulation and conservation, under conditions prevailing in the developing countries. Compounds labelled with stable isotopes are considered particularly valuable under field conditions. The report reviews the present situation and presents specific recommendations to the Directors General of FAO and IAEA

  18. Joint production and corporate pricing: An empirical analysis of joint products in the petroleum industry

    International Nuclear Information System (INIS)

    Karimnejad, H.

    1990-01-01

    This dissertation investigates the pricing mechanism of joint products in large multi-plant and multi-product corporations. The primary objective of this dissertation is to show the consistency of classical theories of production with corporate pricing of joint products. This dissertation has two major parts. Part One provides a theoretical framework for joint production and corporate pricing. In this part, joint production is defined and its historical treatment by classical and contemporary economists is analyzed. Part Two conducts an empirical analysis of joint products in the US petroleum industry. Methods of cost allocation are used in the pricing of each individual petroleum product. Three methods are employed to distribute joint production costs to individual petroleum products. These methods are, the sales value method, the barrel gravity method and the average unit cost method. The empirical findings of dissertation provide useful guidelines for pricing policies of large multi-product corporations

  19. Joint Force Quarterly. Number 4, Spring 1994

    Science.gov (United States)

    1994-05-01

    Martin J. Peters, Jr. Calvin B. Kelley Art Direction Typography and Design Division Government Printing Office Joint Force Quarterly is published by...within larger organizations. For example, the concept 6 JFQ / Spring 1994 of the combined joint task force for Europe is designed to provide just such...or financial, may be the shared outcome for all parties to future conflicts. The image of war, shaped over centuries, is precise, graphic , and

  20. Gnathological splint therapy in temporomandibular joint disorder

    OpenAIRE

    Gnanashanmugham, K.; Saravanan, B.; Sukumar, M. R.; Tajir, T. Faisal

    2015-01-01

    Temporomandibular joint (TMJ) forms an integral functional part of stomatognathic system. Position, shape, structure and function of teeth have an influence on the proper functioning and health of TMJ. But a problem associated with TMJ is often neglected, and treatment for it is mostly restricted to palliative therapy. A proper understanding of the underlying cause of temporomandibular joint disorder (TMD) is necessary to device a proper treatment plan. Etiology of TMDs varies from idiopathic...

  1. Revitalizing Nuclear Operations in the Joint Environment

    Science.gov (United States)

    2014-02-01

    height of the Cold War, US schol - ars and joint operational planners were working simultaneously on weapons development and operational art to employ...leadership’s large-target- category withholds thought necessary to maintain stability in a strategic crisis. The inclusion of nuclear effects and...escalation. The inclusion of these points in tomorrow’s doctrine as well as an intellec- tual discussion on the topic will inform Joint Staff planners

  2. The Case for a Joint Evaluation

    Science.gov (United States)

    2017-01-01

    The Capstone Concept of Joint Operations stresses that “the strength of any Joint Force has always been the combining of unique Service...order. Status Quo of Service Evaluations Across the Services, officers’ careers generally begin with a focus on entry- level technical, managerial ...would retain full control of their current evalu- ation systems. However, the Services’ evaluation systems and information would be fed directly

  3. Kinematics of Hooke universal joint robot wrists

    Science.gov (United States)

    Mckinney, William S., Jr.

    1988-01-01

    The singularity problem associated with wrist mechanisms commonly found on industrial manipulators can be alleviated by redesigning the wrist so that it functions as a three-axis gimbal system. This paper discussess the kinematics of gimbal robot wrists made of one and two Hooke universal joints. Derivations of the resolved rate motion control equations for the single and double Hooke universal joint wrists are presented using the three-axis gimbal system as a theoretical wrist model.

  4. The Temporomandibular Joint Pain Dysfunction Syndrome

    OpenAIRE

    Speck, John E.

    1988-01-01

    When a patient complains of headache, neckache, or earache and these are associated with noisy temporomandibular joint function, restricted opening or increased pain when chewing, a temporomandibular joint or masticatory muscle disorder should be considered in the differential diagnosis, because signs and symptoms of these disorders are common in all age groups. This article indicates the more common etiological contributions, that is, microtrauma, repeated microtrauma, muscle hyperactivity, ...

  5. Joint enterprise: righting a wrong turn?

    OpenAIRE

    Jacobson, Jessica; Kirby, Amy; Hunter, Gillian

    2016-01-01

    This report presents the findings of an exploratory study of joint enterprise, undertaken by the Institute for Criminal Policy Research, in partnership with the Prison Reform Trust, and within funding from the Nuffield Foundation. Joint enterprise is a doctrine of the criminal law which permits multiple defendants to be convicted of the same criminal offence even where they had different types or levels of involvement. It has been the source of great controversy in recent years.\\ud \\ud The st...

  6. Attention, Joint Attention, and Social Cognition

    OpenAIRE

    Mundy, Peter; Newell, Lisa

    2007-01-01

    Before social cognition there is joint processing of information about the attention of self and others. This joint attention requires the integrated activation of a distributed cortical network involving the anterior and posterior attention systems. In infancy, practice with the integrated activation of this distributed attention network is a major contributor to the development of social cognition. Thus, the functional neuroanatomies of social cognition and the anterior–posterior attention ...

  7. Synovial Lipoma of the Subtalar Joint.

    Science.gov (United States)

    Whitaker, Jeffrey M; Richards, Sarah; LeCastre, Michael J; Hooke, Thomas G

    2017-07-01

    Lipomas are benign adipose masses that are rarely associated with synovial membranes. In addition, there are only a few reports describing synovial lipomas in the foot. No reported occurrence of this lesion in the subtalar joint currently exists. This case report documents the presentation, clinical evaluation, advanced imaging, and surgical management of a 45-year-old man with a large synovial lipoma of the subtalar joint.

  8. Detection of Arthritis by Joint Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Maxfield, W. S. [Dept, of Radiology, Louisiana State University School of Medicine, New Orleans, LA (United States); Weiss, T. E.; Tutton, R. H.; Hidalgo, J. U. [Ochsner Clinic and Ochsner Foundation Hospital, New Orleans, LA (United States)

    1969-05-15

    Detection and identification of early arthritis is frequently difficult with routine methods. Several tracers, {sup 131}I human serum albumin (25 {mu}Ci/10 lb), {sup 99m}Tc human serum albumin (1-3 mCi), {sup 131}I iodipamide (40 {mu}Ci/10 lb), and {sup 99m}Tc pertechnetate (10 mCi), have been employed for joint scanning to detect synovitis produced by arthritis in joints of the extremities. When administered intravenously, the 25% increase in localization of these tracers in the synovial membrane, if there is active synovitis, can be demonstrated by scintillation scanning. This ability to detect synovitis at an early stage enables the joint scan to show areas of active synovitis not demonstrated on roentgenograms. The scan may objectively confirm or disprove questionable physical findings. From this standpoint the technique has been useful in determining whether joint pain is functional or due to arthritis as a negative localization tends to rule out active synovitis as the cause of the pain. The scan demonstration of a positive localization of the tracer in several joints when only one area is symptomatic is evidence that joint pain is due to systemic disease. The short half-life tracera permit serial studies to follow the course of an arthritis process. Use of {sup 99m}Tc pertechnetate and an Anger camera have made joint scanning a practical technique for clinical use. A review of the accuracy of joint scanning in 130 cases as compared to roentgenograms is presented. (author)

  9. Periprosthetic Joint Infections: Clinical and Bench Research

    Directory of Open Access Journals (Sweden)

    Laurence Legout

    2013-01-01

    Full Text Available Prosthetic joint infection is a devastating complication with high morbidity and substantial cost. The incidence is low but probably underestimated. Despite a significant basic and clinical research in this field, many questions concerning the definition of prosthetic infection as well the diagnosis and the management of these infections remained unanswered. We review the current literature about the new diagnostic methods, the management and the prevention of prosthetic joint infections.

  10. Joint intentionality: from thin to thick

    Czech Academy of Sciences Publication Activity Database

    Koreň, Ladislav

    2016-01-01

    Roč. 2, č. 1 (2016), s. 75-85 ISSN 2196-9655 R&D Projects: GA ČR GA13-20785S Institutional support: RVO:67985955 Keywords : Tomasello * Cooperation * Joint intentionality * Joint action * Mindreading Subject RIV: AA - Philosophy ; Religion https://www.degruyter.com/view/j/jso.2016.2.issue-1/jso-2015-0047/jso-2015-0047.xml?format=INT

  11. Joint Force Quarterly. Number 34, Spring 2003

    Science.gov (United States)

    2003-07-01

    Office of the Chairman LTG George W. Casey, Jr., USA ■ The Joint Staff MG Reginal G. Clemmons , USA ■ National War College A. Denis Clift ■ Joint...vol. 138, no. 91 (June 23, 1992), p. S 8602. 2 Maurice Matloff, editor, American Military History (Washington: Government Printing Office, 1969), p...was basically flawed and historically inac- curate. During the late 1930s General Maurice Gamelin exacerbated a faulty doctrine by shut- ting off all

  12. HIP JOINT AND HIP ENDOPROSTHESIS BIOMECHANICS

    OpenAIRE

    Jakub Gryka

    2017-01-01

    This article contains a description of the basic issues related to anatomy, loading of hip joint and its endoprosthesis research methods. The methods of testing and simulating hip joint loads, factors that influence the selection of parameters during the design of prostheses, typical solutions to engineering problems related to this topic are presented. The article concludes with short summary of the finite element method for the design of hip replacements.

  13. Use of labeled compounds in tracer experiments

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    The use of radiotracers in research has become common. This chapter looks at some of the underlying assumptions and advantages of labeled compounds: advantages of radiotracers; availability of suitable tracers and labeled compounds; purity of labeled compounds; autoradiolysis; storage of labeled compounds; detection systems for chromatography and electrophoretic methods. 14 refs., 2 figs

  14. Peroxide organometallic compounds and their transformations

    International Nuclear Information System (INIS)

    Razuvaev, G.A.; Brilkina, T.G.

    1976-01-01

    A survey is given experimental works on synthesis and reactions of peroxide organometallic compounds. Reactions have been considered of organometallic compounds with oxygen and organic peroxides which result in formation of both peroxide and non-peroxide products. Possible routes and mechanisms of chemical transformations of peroxide organometallic compounds have been discussed. Reactions of organometallic compounds with oxygen and peroxides have been considered

  15. Hybrid FSWeld-bonded joint fatigue behaviour

    Science.gov (United States)

    Lertora, Enrico; Mandolfino, Chiara; Gambaro, Carla; Pizzorni, Marco

    2018-05-01

    Aluminium alloys, widely used in aeronautics, are increasingly involved in the automotive industry due to the good relationship between mechanical strength and specific weight. The lightening of the structures is the first objective, which allows the decreasing in the weight in motion. The use of aluminium alloys has also seen the introduction of the Friction Stir Welding (FSW) technique for the production of structural overlapping joints. FSW allows us to weld overlap joints free from defects, but with the presence of a structural notch further aggravated by the presence of a "hook" defect near the edge of the weld. Furthermore, FSW presents a weld penetration area connected to the tool geometry and penetration. The experimental activity will be focused on the combination of two different joining techniques, which can synergistically improve the final joint resistance. In particular, the welding and bonding process most commonly known as weld-bonding is defined as a hybrid process, as it combines two different junction processes. In this paper we analyse FSWelded AA6082 aluminium alloy overlapped joint with the aim of quantitatively evaluating the improvement provided by the presence of an epoxy adhesive between the plates. After optimising the weld-bonding process, the mechanical behaviour of welded joints will be analysed by static and dynamic tests. The presence of the adhesive should limit the negative effect of the structural notch inevitable in a FSW overlapped joint.

  16. Joint hypermobility syndrome and related pain

    Directory of Open Access Journals (Sweden)

    Nilay Sahin

    2016-06-01

    Full Text Available Hypermobility is defined as an abnormally increased range of motion of a joint resulting from the excessive laxity of the soft tissues. This paper is focused on this commonly forgotten cause of several morbidities. The etiology of hypermobility is not very well known. One decade ago, joint hypermobility syndrome was considered as a benign condition, but now it is recognized as a significant contributor to chronic musculoskeletal pain, besides impacting on other organs. Patients with joint hypermobility syndrome often have diffuse, chronic complaints that are inconsistent with the musculoskeletal system. Chronic pain may cause loss of proprioception and so increased sensitivity to microtrauma, premature osteoarthritis de- velopment, soft tissue problems, psychosocial disorders, and neurophysiological deficiencies. Osteoarthritis, pes planus, mechanical low back pain, and soft tissue rheumatisms are frequent musculoskeletal findings as well as subluxations, thoracic outlet syndrome, rectal and uterine prolapses, hernias, and stress incontinence. Joint hypermobility syndrome's treatment is not easy, and nonsteroidal anti-inflammatory drugs are not usually effective or adequate. Proprioceptive and strengthening exercises have been reported to have supportive and therapeutic effects, but we have limited data on this issue. Joint hypermobility syndrome must be accepted as a multisystem connective tissue disorder rather than just joint laxities. As a result; clinicians must be aware of complexities of connective tissue disorders and comorbidities. [Arch Clin Exp Surg 2016; 5(2.000: 105-112

  17. Cryotherapy impairs knee joint position sense.

    Science.gov (United States)

    Oliveira, R; Ribeiro, F; Oliveira, J

    2010-03-01

    The effects of cryotherapy on joint position sense are not clearly established; however it is paramount to understand its impact on peripheral feedback to ascertain the safety of using ice therapy before resuming exercise on sports or rehabilitation settings. Thus, the aim of the present study was to determine the effects of cryotherapy, when applied over the quadriceps and over the knee joint, on knee position sense. This within-subjects repeated-measures study encompassed fifteen subjects. Knee position sense was measured by open kinetic chain technique and active positioning at baseline and after cryotherapy application. Knee angles were determined by computer analysis of the videotape images. Twenty-minute ice bag application was applied randomly, in two sessions 48 h apart, over the quadriceps and the knee joint. The main effect for cryotherapy application was significant (F (1.14)=7.7, p=0.015) indicating an increase in both absolute and relative angular errors after the application. There was no significant main effect for the location of cryotherapy application, indicating no differences between the application over the quadriceps and the knee joint. In conclusion, cryotherapy impairs knee joint position sense in normal knees. This deleterious effect is similar when cryotherapy is applied over the quadriceps or the knee joint. Georg Thieme Verlag KG Stuttgart.New York.

  18. Hip joint mobility in dancers: preliminary report.

    Science.gov (United States)

    Drężewska, Marlena; Gałuszka, Renata; Sliwiński, Zbigniew

    2012-01-01

    The aim of this study was to evaluate the impact of dancing on hip joint mobility and to assess the relationship between active movements of the hips and injuries among dancers, which may be important in planning rehabilitation in this group. The sample comprised 49 dancers (37 women and 12 men) aged 15 to 32 years. The participants were the professional dancers of the Kielce Dance Theatre and members of two youth jazz dance teams from the Kielce Dance Theatre. The active range of motion of the hips was measured in three planes using a goniometer in order to assess the influence of dance training on hip joint mobility. A questionnaire-based survey was also conducted. The range of flexion, extension and external rotation was significantly greater in the group of long-time dancers (p <0.05). There was a significantly greater range of flexion, abduction and external rotation in previously injured hip joints (p<0.05). 1. Injuries to hip joints in dancers may result in increased ranges of motion, which may lead to disturbances of joint stability. 2. Being a long-time dancer and the female gender were associated with an increased range of hip joint motion.

  19. Subtalar joint stress imaging with tomosynthesis.

    Science.gov (United States)

    Teramoto, Atsushi; Watanabe, Kota; Takashima, Hiroyuki; Yamashita, Toshihiko

    2014-06-01

    The purpose of this study was to perform stress imaging of hindfoot inversion and eversion using tomosynthesis and to assess the subtalar joint range of motion (ROM) of healthy subjects. The subjects were 15 healthy volunteers with a mean age of 29.1 years. Coronal tomosynthesis stress imaging of the subtalar joint was performed in a total of 30 left and right ankles. A Telos stress device was used for the stress load, and the load was 150 N for both inversion and eversion. Tomographic images in which the posterior talocalcaneal joint could be confirmed on the neutral position images were used in measurements. The angle of the intersection formed by a line through the lateral articular facet of the posterior talocalcaneal joint and a line through the surface of the trochlea of the talus was measured. The mean change in the angle of the calcaneus with respect to the talus was 10.3 ± 4.8° with inversion stress and 5.0 ± 3.8° with eversion stress from the neutral position. The result was a clearer depiction of the subtalar joint, and inversion and eversion ROM of the subtalar joint was shown to be about 15° in healthy subjects. Diagnostic, Level IV.

  20. Expression of CGRP in the temporomandibular joint

    International Nuclear Information System (INIS)

    Caviedes Bucheli, Javier; Medina Buitrago, Diana Marcela

    2002-01-01

    The presence and content of calcitonin gene-related peptide (CGRP) is evaluated in the hyperplastic retrodiscal tissue of the temporomandibular joint in patients with joint degenerative disease by radioimmunoassay. Study population has included 8 female patients in pre-menopausic status, without to be pregnant, without to be lactating for a year and with diagnostic of joint degenerative disease (osteoarthrosis). Pain levels are registered with visual analog scale, where 0 is absence of pain and 16 acute pain. A bone degeneration is classified as mild, moderate and severe, according to findings of nuclear magnetic resonance. The 15 retrodiscal hyperplastic tissue samples are taken from patients undergoing to open surgery of temporomandibular joint. The specimens were placed in plastic blocks with freezing medium and are stored at -70 degrees celsius until neuropeptide extraction by radioimmunoassay with kit for CGRP. A directly proportional relationship is established between the degree of bone degeneration and neuropeptide expression and between the osteoarthrosis classification with analogue visual scale. Findings have shown definitive correlation between pain levels and expression of neuropeptide. CGRP is expressed in the retrodiscal tissue of temporomandibular joint in human with joint degenerative disease and is directly related with levels osteoarthrosis and pain [es