WorldWideScience

Sample records for chromatography methods instrumentation

  1. Analytical chromatography. Methods, instrumentation and applications

    International Nuclear Information System (INIS)

    Yashin, Ya I; Yashin, A Ya

    2006-01-01

    The state-of-the-art and the prospects in the development of main methods of analytical chromatography, viz., gas, high performance liquid and ion chromatographic techniques, are characterised. Achievements of the past 10-15 years in the theory and general methodology of chromatography and also in the development of new sorbents, columns and chromatographic instruments are outlined. The use of chromatography in the environmental control, biology, medicine, pharmaceutics, and also for monitoring the quality of foodstuffs and products of chemical, petrochemical and gas industries, etc. is considered.

  2. Schinus terebinthifolius countercurrent chromatography (Part III): Method transfer from small countercurrent chromatography column to preparative centrifugal partition chromatography ones as a part of method development.

    Science.gov (United States)

    das Neves Costa, Fernanda; Hubert, Jane; Borie, Nicolas; Kotland, Alexis; Hewitson, Peter; Ignatova, Svetlana; Renault, Jean-Hugues

    2017-03-03

    Countercurrent chromatography (CCC) and centrifugal partition chromatography (CPC) are support free liquid-liquid chromatography techniques sharing the same basic principles and features. Method transfer has previously been demonstrated for both techniques but never from one to another. This study aimed to show such a feasibility using fractionation of Schinus terebinthifolius berries dichloromethane extract as a case study. Heptane - ethyl acetate - methanol -water (6:1:6:1, v/v/v/v) was used as solvent system with masticadienonic and 3β-masticadienolic acids as target compounds. The optimized separation methodology previously described in Part I and II, was scaled up from an analytical hydrodynamic CCC column (17.4mL) to preparative hydrostatic CPC instruments (250mL and 303mL) as a part of method development. Flow-rate and sample loading were further optimized on CPC. Mobile phase linear velocity is suggested as a transfer invariant parameter if the CPC column contains sufficient number of partition cells. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Robotic thin layer chromatography instrument for synthetic chemistry

    International Nuclear Information System (INIS)

    Corkan, L.A.; Haynes, E.; Kline, S.; Lindsey, J.S.

    1991-01-01

    We have constructed a second generation instrument for performing automated thin layer chromatography (TLC), The TLC instrument Consists of four dedicated stations for (1) plate dispensing, (2) sample application, (3) plate development, and (4) densitometry. A robot is used to move TLC plates among stations. The TLC instrument functions either as a stand-alone unit or as one analytical module in a robotic workstation for synthetic chemistry. An integrated hardware and software architecture enables automatic TLC analysis of samples produced concurrently from synthetic reactions in progress on the workstation. The combination of fixed automation and robotics gives a throughput of 12 TLC samples per hour. From these results a blueprint has emerged for an advanced automated TLC instrument with far greater throughput and analytical capabilities

  4. Plasma chromatography

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    This book examines the fundamental theory and various applications of ion mobility spectroscopy. Plasma chromatography developed from research on the diffusion and mobility of ions. Topics considered include instrument design and description (e.g., performance, spectral interpretation, sample handling, mass spectrometry), the role of ion mobility in plasma chromatography (e.g., kinetic theory of ion transport), atmospheric pressure ionization (e.g., rate equations), the characterization of isomers by plasma chromatography (e.g., molecular ion characteristics, polynuclear aromatics), plasma chromatography as a gas chromatographic detection method (e.g., qualitative analysis, continuous mobility monitoring, quantitative analysis), the analysis of toxic vapors by plasma chromatography (e.g., plasma chromatograph calibration, instrument control and data processing), the analysis of semiconductor devices and microelectronic packages by plasma chromatography/mass spectroscopy (e.g., analysis of organic surface contaminants, analysis of water in sealed electronic packages), and instrument design and automation (hardware, software)

  5. Ion Chromatography Applications in Wastewater Analysis

    Directory of Open Access Journals (Sweden)

    Rajmund Michalski

    2018-02-01

    Full Text Available Wastewater analysis is an important area in analytical and environmental chemistry. It can be performed with both the classic wet methods and instrumental techniques. The development of new methods, and modification of the existing ones, constitute a major task for researchers. Ion chromatography plays a predominant role in ion determinations with the instrumental methods. It offers several advantages over the conventional methods, such as simultaneous determinations of alkali and alkaline earth cations and ammonia. Ammonium ions cannot be determined by spectroscopic methods. Ion chromatography has been accepted world-wide as a reference method for analyzing anions and cations in water and wastewater due to the fact that it enables the replacement of several individual wet chemistry methods for common ions with one instrumental technique. The following article describes the principles of ion chromatography, such as stationary phases, eluents, detectors, and sample preparation methods. Moreover, the applications of ion chromatography in wastewater analyses and international standards are presented.

  6. Laboratory and field based evaluation of chromatography ...

    Science.gov (United States)

    The Monitor for AeRosols and GAses in ambient air (MARGA) is an on-line ion-chromatography-based instrument designed for speciation of the inorganic gas and aerosol ammonium-nitrate-sulfate system. Previous work to characterize the performance of the MARGA has been primarily based on field comparison to other measurement methods to evaluate accuracy. While such studies are useful, the underlying reasons for disagreement among methods are not always clear. This study examines aspects of MARGA accuracy and precision specifically related to automated chromatography analysis. Using laboratory standards, analytical accuracy, precision, and method detection limits derived from the MARGA chromatography software are compared to an alternative software package (Chromeleon, Thermo Scientific Dionex). Field measurements are used to further evaluate instrument performance, including the MARGA’s use of an internal LiBr standard to control accuracy. Using gas/aerosol ratios and aerosol neutralization state as a case study, the impact of chromatography on measurement error is assessed. The new generation of on-line chromatography-based gas and particle measurement systems have many advantages, including simultaneous analysis of multiple pollutants. The Monitor for Aerosols and Gases in Ambient Air (MARGA) is such an instrument that is used in North America, Europe, and Asia for atmospheric process studies as well as routine monitoring. While the instrument has been evaluat

  7. Constructing a LabVIEW-Controlled High-Performance Liquid Chromatography (HPLC) System: An Undergraduate Instrumental Methods Exercise

    Science.gov (United States)

    Smith, Eugene T.; Hill, Marc

    2011-01-01

    In this laboratory exercise, students develop a LabVIEW-controlled high-performance liquid chromatography system utilizing a data acquisition device, two pumps, a detector, and fraction collector. The programming experience involves a variety of methods for interface communication, including serial control, analog-to-digital conversion, and…

  8. Instrumental liquid chromatography: a practical manual on high-performance liquid chromatographic methods

    National Research Council Canada - National Science Library

    Parris, N. A

    1976-01-01

    Available texts on liquid chromatography have tended to emphasize the developments in the theoretical understanding of the technique and methodology or to list numerous applications, complete with experimental details...

  9. Development of a high performance liquid chromatography method ...

    African Journals Online (AJOL)

    Development of a high performance liquid chromatography method for simultaneous ... Purpose: To develop and validate a new low-cost high performance liquid chromatography (HPLC) method for ..... Several papers have reported the use of ...

  10. Easy instrumental analysis

    International Nuclear Information System (INIS)

    Ko, Myeong Su; Kim, Tae Hwa; Park, Gyu Hyeon; Yang, Jong Beom; Oh, Chang Hwan; Lee, Kyoung Hye

    2010-04-01

    This textbook describes instrument analysis in easy way with twelve chapters. The contents of the book are pH measurement on principle, pH meter, pH measurement, examples of the experiments, centrifugation, Absorptiometry, Fluorescent method, Atomic absorption analysis, Gas-chromatography, Gas chromatography-mass spectrometry, High performance liquid chromatography liquid chromatograph-mass spectrometry, Electrophoresis on practical case and analysis of the result and examples, PCR on principle, device, application and examples and Enzyme-linked immunosorbent assay with indirect ELISA, sandwich ELISA and ELISA reader.

  11. Easy instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Myeong Su; Kim, Tae Hwa; Park, Gyu Hyeon; Yang, Jong Beom; Oh, Chang Hwan; Lee, Kyoung Hye

    2010-04-15

    This textbook describes instrument analysis in easy way with twelve chapters. The contents of the book are pH measurement on principle, pH meter, pH measurement, examples of the experiments, centrifugation, Absorptiometry, Fluorescent method, Atomic absorption analysis, Gas-chromatography, Gas chromatography-mass spectrometry, High performance liquid chromatography liquid chromatograph-mass spectrometry, Electrophoresis on practical case and analysis of the result and examples, PCR on principle, device, application and examples and Enzyme-linked immunosorbent assay with indirect ELISA, sandwich ELISA and ELISA reader.

  12. Instrument platforms for nano liquid chromatography.

    Science.gov (United States)

    Šesták, Jozef; Moravcová, Dana; Kahle, Vladislav

    2015-11-20

    The history of liquid chromatography started more than a century ago and miniaturization and automation are two leading trends in this field. Nanocolumn liquid chromatography (nano LC) and largely synonymous capillary liquid chromatography (capillary LC) are the most recent results of this process where miniaturization of column dimensions and sorbent particle size play crucial role. Very interesting results achieved in the research of extremely miniaturized LC columns at the end of the last century lacked distinctive raison d'être and only advances in mass spectrometry brought a real breakthrough. Configuration of nano LC-electrospray ionization mass spectrometry (LC-ESI-MS) has become a basic tool in bioanalytical chemistry, especially in proteomics. This review discusses and summarizes past and current trends in the realization of nano liquid chromatography (nano LC) platforms. Special attention is given to the mobile phase delivery under nanoflow rates (isocratic, gradient) and sample injection to the nanocolumn. Available detection techniques applied in nano LC separations are also briefly discussed. We followed up the key themes from the original scientific reports over gradual improvements up to the contemporary commercial solutions. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. A review of modern instrumental methods of elemental analysis of petroleum related material. Part 2

    International Nuclear Information System (INIS)

    Nadkarni, R.A.

    1991-01-01

    In this paper a review is presented of the state of the art in elemental analysis of petroleum-related materials (crude oil, gasoline, additives, and lubricants) using modern instrumental analysis techniques. The major instrumental techniques used for elemental analysis of petroleum products include atomic absorption spectrometry (both with flame and with graphite furnace atomizer), inductively coupled plasma atomic emission spectrometry, ion chromatography, microelemental methods, neutron activation, spark source mass spectrometry, and x-ray fluorescence. Each of these techniques is compared for its advantages, disadvantages, and typical applications in the petroleum field

  14. Cromatografia unificada Unified chromatography

    Directory of Open Access Journals (Sweden)

    Carin von Mühlen

    2004-10-01

    Full Text Available The scope of this study encompasses an overview of the principles of unified chromatography as well as the principles of chromatographic techniques as applied to unified systems, which include gas chromatography, liquid chromatography, supercritical fluid chromatography, high temperature and high pressure liquid chromatography, micro-liquid chromatography, enhanced fluidity chromatography, and solvating gas chromatography. Theoretical considerations and individual instrumental parameters such as mobile phase, sample introduction system, columns, and detection system are also discussed. Future applications of this separation approach are discussed.

  15. Column Liquid Chromatography.

    Science.gov (United States)

    Majors, Ronald E.; And Others

    1984-01-01

    Reviews literature covering developments of column liquid chromatography during 1982-83. Areas considered include: books and reviews; general theory; columns; instrumentation; detectors; automation and data handling; multidimensional chromatographic and column switching techniques; liquid-solid chromatography; normal bonded-phase, reversed-phase,…

  16. Setting up of a liquid chromatography-high resolution tandem mass spectrometry method for the detection of caseins in food. A comparison with ELISA method

    Directory of Open Access Journals (Sweden)

    Daniela Gastaldi

    2013-06-01

    Full Text Available Determination of caseins in food matrices is usually performed by using the competitiveenzyme- linked immunosorbent assay (ELISA technique. However such a technique suffers from a number of limitations. Among these, the applicability to a narrow concentration range, a non linear (logarithmic response, a non-negligible cross-reactivity and a high cost per kit. At the time of the completion of this study, in case of ELISA positive feedback, there was poor availability in the literature of finding reliable instrumental methods able to determine both qualitatively and quantitatively this class of substances. In the present study, a liquid chromatography-high resolution tandem mass spectrometry (HPLC-HRMS/MS instrumental method was developed with a high resolution mass spectrometer (Orbitrap. Real samples of sausages in which caseins were detected by ELISA technique were analysed. A casein-free sample of ham was used as a blank. The analytical characteristics of the instrumental method were compared with those of a commercial ELISA test, declared specific for α- and β-casein.

  17. Gradient High Performance Liquid Chromatography Method ...

    African Journals Online (AJOL)

    Purpose: To develop a gradient high performance liquid chromatography (HPLC) method for the simultaneous determination of phenylephrine (PHE) and ibuprofen (IBU) in solid ..... nimesulide, phenylephrine. Hydrochloride, chlorpheniramine maleate and caffeine anhydrous in pharmaceutical dosage form. Acta Pol.

  18. Liquid chromatography detection unit, system, and method

    Science.gov (United States)

    Derenzo, Stephen E.; Moses, William W.

    2015-10-27

    An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method of liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.

  19. Validated High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, rapid and sensitive high performance liquid chromatography (HPLC) method for the determination of cefadroxil monohydrate in human plasma. Methods: Schimadzu HPLC with LC solution software was used with Waters Spherisorb, C18 (5 μm, 150mm × 4.5mm) column. The mobile phase ...

  20. Instrument platforms for nano liquid chromatography

    Czech Academy of Sciences Publication Activity Database

    Šesták, Jozef; Moravcová, Dana; Kahle, Vladislav

    2015-01-01

    Roč. 1421, NOV (2015), s. 2-17 ISSN 0021-9673 R&D Projects: GA MV VG20112015021 Institutional support: RVO:68081715 Keywords : nano liquid chromatography * splitless gradient generation * nano LC platforms Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.926, year: 2015 http://hdl.handle.net/11104/0250900

  1. Instrumental methods of analysis, 7th edition

    International Nuclear Information System (INIS)

    Willard, H.H.; Merritt, L.L. Jr.; Dean, J.A.; Settle, F.A. Jr.

    1988-01-01

    The authors have prepared an organized and generally polished product. The book is fashioned to be used as a textbook for an undergraduate instrumental analysis course, a supporting textbook for graduate-level courses, and a general reference work on analytical instrumentation and techniques for professional chemists. Four major areas are emphasized: data collection and processing, spectroscopic instrumentation and methods, liquid and gas chromatographic methods, and electrochemical methods. Analytical instrumentation and methods have been updated, and a thorough citation of pertinent recent literature is included

  2. Lipidomic analysis of biological samples: Comparison of liquid chromatography, supercritical fluid chromatography and direct infusion mass spectrometry methods.

    Science.gov (United States)

    Lísa, Miroslav; Cífková, Eva; Khalikova, Maria; Ovčačíková, Magdaléna; Holčapek, Michal

    2017-11-24

    Lipidomic analysis of biological samples in a clinical research represents challenging task for analytical methods given by the large number of samples and their extreme complexity. In this work, we compare direct infusion (DI) and chromatography - mass spectrometry (MS) lipidomic approaches represented by three analytical methods in terms of comprehensiveness, sample throughput, and validation results for the lipidomic analysis of biological samples represented by tumor tissue, surrounding normal tissue, plasma, and erythrocytes of kidney cancer patients. Methods are compared in one laboratory using the identical analytical protocol to ensure comparable conditions. Ultrahigh-performance liquid chromatography/MS (UHPLC/MS) method in hydrophilic interaction liquid chromatography mode and DI-MS method are used for this comparison as the most widely used methods for the lipidomic analysis together with ultrahigh-performance supercritical fluid chromatography/MS (UHPSFC/MS) method showing promising results in metabolomics analyses. The nontargeted analysis of pooled samples is performed using all tested methods and 610 lipid species within 23 lipid classes are identified. DI method provides the most comprehensive results due to identification of some polar lipid classes, which are not identified by UHPLC and UHPSFC methods. On the other hand, UHPSFC method provides an excellent sensitivity for less polar lipid classes and the highest sample throughput within 10min method time. The sample consumption of DI method is 125 times higher than for other methods, while only 40μL of organic solvent is used for one sample analysis compared to 3.5mL and 4.9mL in case of UHPLC and UHPSFC methods, respectively. Methods are validated for the quantitative lipidomic analysis of plasma samples with one internal standard for each lipid class. Results show applicability of all tested methods for the lipidomic analysis of biological samples depending on the analysis requirements

  3. Purification of flavonoids from licorice using an off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method.

    Science.gov (United States)

    Fan, Yunpeng; Fu, Yanhui; Fu, Qing; Cai, Jianfeng; Xin, Huaxia; Dai, Mei; Jin, Yu

    2016-07-01

    An orthogonal (71.9%) off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method coupled with effective sample pretreatment was developed for separation and purification of flavonoids from licorice. Most of the nonflavonoids were firstly removed using a self-made Click TE-Cys (60 μm) solid-phase extraction. In the first dimension, an industrial grade preparative chromatography was employed to purify the crude flavonoids. Click TE-Cys (10 μm) was selected as the stationary phase that provided an excellent separation with high reproducibility. Ethyl acetate/ethanol was selected as the mobile phase owing to their excellent solubility for flavonoids. Flavonoids co-eluted in the first dimension were selected for further purification using reversed-phase liquid chromatography. Multiple compounds could be isolated from one normal-phase fraction and some compounds with bad resolution in one-dimensional liquid chromatography could be prepared in this two-dimensional system owing to the orthogonal separation. Moreover, this two-dimensional liquid chromatography method was beneficial for the preparation of relatively trace flavonoid compounds, which were enriched in the first dimension and further purified in the second dimension. Totally, 24 flavonoid compounds with high purity were obtained. The results demonstrated that the off-line two-dimensional liquid chromatography method was effective for the preparative separation and purification of flavonoids from licorice. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Solvent Front Position Extraction procedure with thin-layer chromatography as a mode of multicomponent sample preparation for quantitative analysis by instrumental technique.

    Science.gov (United States)

    Klimek-Turek, A; Sikora, E; Dzido, T H

    2017-12-29

    A concept of using thin-layer chromatography to multicomponent sample preparation for quantitative determination of solutes followed by instrumental technique is presented. Thin-layer chromatography (TLC) is used to separate chosen substances and their internal standard from other components (matrix) and to form a single spot/zone containing them at the solvent front position. The location of the analytes and internal standard in the solvent front zone allows their easy extraction followed by quantitation by HPLC. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Liquid chromatography method to determine polyamines in thermosetting polymers

    International Nuclear Information System (INIS)

    Dopico-Garcia, M.S.; Lopez-Vilarino, J.M.; Fernandez-Martinez, G.; Gonzalez-Rodriguez, M.V.

    2010-01-01

    A simple, robust and sensitive analytical method to determine three polyamines commonly used as hardeners in epoxy resin systems and in the manufacture of polyurethane is reported. The studied polyamines are: one tetramine, TETA (triethylenetetramine), and two diamines, IPDA (Isophorone diamine) and TCD-diamine (4,7-methano-1H-indene-5,?-dimethanamine, octahydro-). The latter has an incompletely defined structure, and, as far as we know, has not been previously determined by other methods. All three polyamines contain primary amines; TETA also contains secondary amines. The analytical method involves derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate, used for the first time for these compounds, followed by high performance liquid chromatography (HPLC) analysis with a fluorescence (FL) detector (λ excitation 248 nm, λ emision 395 nm). The HPLC-DAD-LTQ Orbitrap MS was used in order to provide structural information about the obtained derivatized compounds. The hybrid linear ion trap LTQ Orbitrap mass spectrometer has been introduced in recent years and provides a high mass accuracy. The structures of the derivatized analytes were identified from the protonated molecular ions [M+H] + and corresponded to the fully labelled analytes. The following analytical parameters were determined for the method using the HPLC-FL: linearity, precision (2.5-10%), instrumental precision intraday (0.8-1.5%) and interday (2.9-6.3%), and detection limits (0.02-0.14 mg L -1 ). The stability of stock solutions and derivatized compounds was also investigated. The method was applied to determine the amine free content in epoxy resin dust collected in workplaces.

  6. Liquid chromatography method to determine polyamines in thermosetting polymers

    Energy Technology Data Exchange (ETDEWEB)

    Dopico-Garcia, M.S. [Laboratorio de Quimica - Centro de Investigacions Tecnoloxicas, Universidade da Coruna, Campus de Esteiro s/n, 15403 Ferrol (Spain); Centro Galego do Plastico, A Cabana s/n, 15590 Ferrol (Spain); Lopez-Vilarino, J.M. [Laboratorio de Quimica - Centro de Investigacions Tecnoloxicas, Universidade da Coruna, Campus de Esteiro s/n, 15403 Ferrol (Spain); Fernandez-Martinez, G. [Unidad de Tecnicas Cromatograficas, Servizos de Apoio a Investigacion, Edificio Servizos Centrais de Investigacion, Universidade da Coruna, Campus de Elvina s/n, 15071 A Coruna (Spain); Gonzalez-Rodriguez, M.V., E-mail: victoria@udc.es [Dpto. de Quimica Analitica - E.U. Politecnica, Universidade da Coruna, Avda. 19 de Febrero s/n, 15405 Ferrol (Spain)

    2010-05-14

    A simple, robust and sensitive analytical method to determine three polyamines commonly used as hardeners in epoxy resin systems and in the manufacture of polyurethane is reported. The studied polyamines are: one tetramine, TETA (triethylenetetramine), and two diamines, IPDA (Isophorone diamine) and TCD-diamine (4,7-methano-1H-indene-5,?-dimethanamine, octahydro-). The latter has an incompletely defined structure, and, as far as we know, has not been previously determined by other methods. All three polyamines contain primary amines; TETA also contains secondary amines. The analytical method involves derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate, used for the first time for these compounds, followed by high performance liquid chromatography (HPLC) analysis with a fluorescence (FL) detector ({lambda} excitation 248 nm, {lambda} emision 395 nm). The HPLC-DAD-LTQ Orbitrap MS was used in order to provide structural information about the obtained derivatized compounds. The hybrid linear ion trap LTQ Orbitrap mass spectrometer has been introduced in recent years and provides a high mass accuracy. The structures of the derivatized analytes were identified from the protonated molecular ions [M+H]{sup +} and corresponded to the fully labelled analytes. The following analytical parameters were determined for the method using the HPLC-FL: linearity, precision (2.5-10%), instrumental precision intraday (0.8-1.5%) and interday (2.9-6.3%), and detection limits (0.02-0.14 mg L{sup -1}). The stability of stock solutions and derivatized compounds was also investigated. The method was applied to determine the amine free content in epoxy resin dust collected in workplaces.

  7. Chromatography and mass spectrometry of chemical warfare agents, toxins and related compounds: state of the art and future prospects

    NARCIS (Netherlands)

    Kientz, C.E.

    1998-01-01

    Methods for the identification of chemical warfare agents, toxins, bioregulators and related products are frequently reported in literature. These methods are often based on instrumental analysis using chromatography (gas and liquid) and mass spectrometry. Here, these instrumental techniques are

  8. Schinus terebinthifolius countercurrent chromatography (Part II): Intra-apparatus scale-up and inter-apparatus method transfer.

    Science.gov (United States)

    Costa, Fernanda das Neves; Vieira, Mariana Neves; Garrard, Ian; Hewitson, Peter; Jerz, Gerold; Leitão, Gilda Guimarães; Ignatova, Svetlana

    2016-09-30

    Countercurrent chromatography (CCC) is being widely used across the world for purification of various materials, especially in natural product research. The predictability of CCC scale-up has been successfully demonstrated using specially designed instruments of the same manufacturer. The reality is that the most of CCC users do not have access to such instruments and do not have enough experience to transfer methods from one CCC column to another. This unique study of three international teams is based on innovative approach to simplify the scale-up between different CCC machines using fractionation of Schinus terebinthifolius berries dichloromethane extract as a case study. The optimized separation methodology, recently developed by the authors (Part I), was repeatedly performed on CCC columns of different design available at most research laboratories across the world. Hexane - ethyl acetate - methanol - water (6:1:6:1, v/v/v/v) was used as solvent system with masticadienonic and 3β-masticadienolic acids as target compounds to monitor stationary phase retention and calculate peak resolution. It has been demonstrated that volumetric, linear and length scale-up transfer factors based on column characteristics can be directly applied to different i.d., volume and length columns independently on instrument make in an intra-apparatus scale-up and inter-apparatus method transfer. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Liquid chromatography coupled to on-line post column derivatization for the determination of organic compounds: A review on instrumentation and chemistries

    International Nuclear Information System (INIS)

    Zacharis, Constantinos K.; Tzanavaras, Paraskevas D.

    2013-01-01

    Graphical abstract: -- Highlights: •Review on liquid chromatography coupled to post-column derivatization. •Overview of instrumentation for post-column derivatization. •Post-column chemistries for analysis of organic compounds. -- Abstract: Analytical derivatization either in pre or post column modes is one of the most widely used sample pretreatment techniques coupled to liquid chromatography. In the present review article we selected to discuss the post column derivatization mode for the analysis of organic compounds. The first part of the review focuses to the instrumentation of post-column setups including not only fundamental components such as pumps and reactors but also less common parts such as static mixers and back-pressure regulators; the second part of the article discusses the most popular “chemistries” that are involved in post column applications, including reagent-less approaches and new sensing platforms such as the popular gold nanoparticles. Some representative recent applications are also presented as tables

  10. Liquid chromatography coupled to on-line post column derivatization for the determination of organic compounds: A review on instrumentation and chemistries

    Energy Technology Data Exchange (ETDEWEB)

    Zacharis, Constantinos K., E-mail: zacharis@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotelian University of Thessaloniki, GR-54124 Thessaloniki (Greece); Department of Food Technology, School of Food Technology and Nutrition, Alexander Technological Educational Institute (ATEI) of Thessaloniki, 57400 Thessaloniki (Greece); Tzanavaras, Paraskevas D., E-mail: ptzanava@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotelian University of Thessaloniki, GR-54124 Thessaloniki (Greece)

    2013-10-10

    Graphical abstract: -- Highlights: •Review on liquid chromatography coupled to post-column derivatization. •Overview of instrumentation for post-column derivatization. •Post-column chemistries for analysis of organic compounds. -- Abstract: Analytical derivatization either in pre or post column modes is one of the most widely used sample pretreatment techniques coupled to liquid chromatography. In the present review article we selected to discuss the post column derivatization mode for the analysis of organic compounds. The first part of the review focuses to the instrumentation of post-column setups including not only fundamental components such as pumps and reactors but also less common parts such as static mixers and back-pressure regulators; the second part of the article discusses the most popular “chemistries” that are involved in post column applications, including reagent-less approaches and new sensing platforms such as the popular gold nanoparticles. Some representative recent applications are also presented as tables.

  11. Theories to support method development in comprehensive two-dimensional liquid chromatography - A review

    NARCIS (Netherlands)

    Bedani, F.; Schoenmakers, P.J.; Janssen, H.-G.

    2012-01-01

    On-line comprehensive two-dimensional liquid chromatography techniques promise to resolve samples that current one-dimensional liquid chromatography methods cannot adequately deal with. To make full use of the potential of two-dimensional liquid chromatography, optimization is required. Optimization

  12. Instrumentation for analytical scale supercritical fluid chromatography.

    Science.gov (United States)

    Berger, Terry A

    2015-11-20

    Analytical scale supercritical fluid chromatography (SFC) is largely a sub-discipline of high performance liquid chromatography (HPLC), in that most of the hardware and software can be used for either technique. The aspects that separate the 2 techniques stem from the use of carbon dioxide (CO2) as the main component of the mobile phase in SFC. The high compressibility and low viscosity of CO2 mean that pumps, and autosamplers designed for HPLC either need to be modified or an alternate means of dealing with compressibility needs to be found. The inclusion of a back pressure regulator and a high pressure flow cell for any UV-Vis detector are also necessary. Details of the various approaches, problems and solutions are described. Characteristics, such as adiabatic vs. isothermal compressibility, thermal gradients, and refractive index issues are dealt with in detail. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Liquid chromatography method to determine polyamines in thermosetting polymers.

    Science.gov (United States)

    Dopico-García, M S; López-Vilariño, J M; Fernández-Martínez, G; González-Rodríguez, M V

    2010-05-14

    A simple, robust and sensitive analytical method to determine three polyamines commonly used as hardeners in epoxy resin systems and in the manufacture of polyurethane is reported. The studied polyamines are: one tetramine, TETA (triethylenetetramine), and two diamines, IPDA (Isophorone diamine) and TCD-diamine (4,7-methano-1H-indene-5,?-dimethanamine, octahydro-). The latter has an incompletely defined structure, and, as far as we know, has not been previously determined by other methods. All three polyamines contain primary amines; TETA also contains secondary amines. The analytical method involves derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate, used for the first time for these compounds, followed by high performance liquid chromatography (HPLC) analysis with a fluorescence (FL) detector (lambda excitation 248nm, lambda emision 395nm). The HPLC-DAD-LTQ Orbitrap MS was used in order to provide structural information about the obtained derivatized compounds. The hybrid linear ion trap LTQ Orbitrap mass spectrometer has been introduced in recent years and provides a high mass accuracy. The structures of the derivatized analytes were identified from the protonated molecular ions [M+H](+) and corresponded to the fully labelled analytes. The following analytical parameters were determined for the method using the HPLC-FL: linearity, precision (2.5-10%), instrumental precision intraday (0.8-1.5%) and interday (2.9-6.3%), and detection limits (0.02-0.14mgL(-1)). The stability of stock solutions and derivatized compounds was also investigated. The method was applied to determine the amine free content in epoxy resin dust collected in workplaces. Copyright 2010 Elsevier B.V. All rights reserved.

  14. Analytical method for high resolution liquid chromatography for quality control French Macaw

    International Nuclear Information System (INIS)

    Garcia Penna, Caridad M; Torres Amaro, Leonid; Menendez Castillo, Rosa; Sanchez, Esther; Martinez Espinosa, Vivian; Gonzalez, Maria Lidia; Rodriguez, Carlos

    2007-01-01

    Was developed and validated an analytical method for high resolution liquid chromatography applicable to quality control of drugs dry French Macaw (Senna alata L. Roxb.) With ultraviolet detection at 340 nm. The method for high resolution liquid chromatography used to quantify the sennosides A and B, main components, was validated and proved to be specific, linear, precise and accurate. (Author)

  15. Fluidos supercríticos em química analítica. II. Cromatografia com fluido supercrítico: instrumentação Supercritical fluid in analytical chemistry. II. Supercritical fluid chromatography: instrumentation

    Directory of Open Access Journals (Sweden)

    Emanuel Carrilho

    2003-10-01

    Full Text Available The first paper in this series discussed the basic theory involved in supercritical fluid chromatography (SFC and how the technique progressed from gas and liquid chromatography. The first SFC instruments were simple adaptations of the commercially available liquid chromatographs with packed columns followed by modifications in gas chromatographs using open tubular capillary columns. In this paper, the most important aspects regarding instrumentation are covered, including practical, simple, and the most important, inexpensive solutions to build a home-made SFC system.

  16. Use of laminar chromatographic methods for determination of separation conditions in column extraction chromatography

    International Nuclear Information System (INIS)

    Ghersini, G.; Cerrai, E.

    1978-01-01

    Possibilities of using laminar chromatographic methods (paper and thin-layer chromatography) to determine optimal separation conditions in column extraction chromatography are analysed. Most of the given laminar methods are presented as Rf-spectra, i.e. as dependences of Rf found experimentally on eluating solution component concentration. Interrelation between Rf and distribution coefficients of corresponding liquid extraction systems and retention volumes of chromatographic columns is considered. Literature data on extraction paper and thin-layer chromatography of elements with various immovable phases are presented

  17. Methods of uranium isotpic separation by chemical exchange chromatography

    International Nuclear Information System (INIS)

    Pena V, L.A.; Valle M, L.

    1985-01-01

    Chemical exchange chromatography as applied to isotope separation has undergone a constant development during the last few years. The results so far indicate that this method could eventually become commercially useful. This work presents a critical review of the experimental methods presently under study by principal research groups, and which have not get been compared. (Author)

  18. Gas chromatography in space

    Science.gov (United States)

    Akapo, S. O.; Dimandja, J. M.; Kojiro, D. R.; Valentin, J. R.; Carle, G. C.

    1999-01-01

    Gas chromatography has proven to be a very useful analytical technique for in situ analysis of extraterrestrial environments as demonstrated by its successful operation on spacecraft missions to Mars and Venus. The technique is also one of the six scientific instruments aboard the Huygens probe to explore Titan's atmosphere and surface. A review of gas chromatography in previous space missions and some recent developments in the current environment of fiscal constraints and payload size limitations are presented.

  19. Computational and instrumental methods in EPR

    CERN Document Server

    Bender, Christopher J

    2006-01-01

    Computational and Instrumental Methods in EPR Prof. Bender, Fordham University Prof. Lawrence J. Berliner, University of Denver Electron magnetic resonance has been greatly facilitated by the introduction of advances in instrumentation and better computational tools, such as the increasingly widespread use of the density matrix formalism. This volume is devoted to both instrumentation and computation aspects of EPR, while addressing applications such as spin relaxation time measurements, the measurement of hyperfine interaction parameters, and the recovery of Mn(II) spin Hamiltonian parameters via spectral simulation. Key features: Microwave Amplitude Modulation Technique to Measure Spin-Lattice (T1) and Spin-Spin (T2) Relaxation Times Improvement in the Measurement of Spin-Lattice Relaxation Time in Electron Paramagnetic Resonance Quantitative Measurement of Magnetic Hyperfine Parameters and the Physical Organic Chemistry of Supramolecular Systems New Methods of Simulation of Mn(II) EPR Spectra: Single Cryst...

  20. Lipidomics by Supercritical Fluid Chromatography

    Directory of Open Access Journals (Sweden)

    Laurent Laboureur

    2015-06-01

    Full Text Available This review enlightens the role of supercritical fluid chromatography (SFC in the field of lipid analysis. SFC has been popular in the late 1980s and 1990s before almost disappearing due to the commercial success of liquid chromatography (LC. It is only 20 years later that a regain of interest appeared when new commercial instruments were introduced. As SFC is fully compatible with the injection of extracts in pure organic solvent, this technique is perfectly suitable for lipid analysis and can be coupled with either highly universal (UV or evaporative light scattering or highly specific (mass spectrometry detection methods. A short history of the use of supercritical fluids as mobile phase for the separation oflipids will be introduced first. Then, the advantages and drawbacks of SFC are discussed for each class of lipids (fatty acyls, glycerolipids, glycerophospholipids, sphingolipids, sterols, prenols, polyketides defined by the LIPID MAPS consortium.

  1. Lipidomics by Supercritical Fluid Chromatography

    Science.gov (United States)

    Laboureur, Laurent; Ollero, Mario; Touboul, David

    2015-01-01

    This review enlightens the role of supercritical fluid chromatography (SFC) in the field of lipid analysis. SFC has been popular in the late 1980s and 1990s before almost disappearing due to the commercial success of liquid chromatography (LC). It is only 20 years later that a regain of interest appeared when new commercial instruments were introduced. As SFC is fully compatible with the injection of extracts in pure organic solvent, this technique is perfectly suitable for lipid analysis and can be coupled with either highly universal (UV or evaporative light scattering) or highly specific (mass spectrometry) detection methods. A short history of the use of supercritical fluids as mobile phase for the separation oflipids will be introduced first. Then, the advantages and drawbacks of SFC are discussed for each class of lipids (fatty acyls, glycerolipids, glycerophospholipids, sphingolipids, sterols, prenols, polyketides) defined by the LIPID MAPS consortium. PMID:26090714

  2. Determination of Alternaria mycotoxins in wine and juice using ionic liquid modified countercurrent chromatography as a pretreatment method followed by high-performance liquid chromatography.

    Science.gov (United States)

    Fan, Chen; Cao, Xueli; Liu, Man; Wang, Wei

    2016-03-04

    Alternariol (AOH), alternariol monomethyl ether (AME), and tenuazonic acid (TeA) are some of the main Alternaria mycotoxins that can be found as contaminants in food materials. The objective of this study was to develop a pretreatment method with countercurrent chromatography (CCC) for enrichment and cleanup of trace Alternaria mycotoxins in food samples prior to high-performance liquid chromatography (HPLC) analysis. An Analytical CCC instrument with a column volume 22.5mL was used, and a two-phase solvent system composed of ethyl acetate and water modified with 6% [HOOMIM][Cl] in mass to volume ratio was selected. Under the optimized CCC operation conditions, trace amounts of AOH, AME, and TeA in large volume of liquid sample were efficiently extracted and enriched in the stationary phase, and then eluted out just by reversing the stationary phase as mobile phase in the opposite flowing direction tail-to-head. The enrichment and elution strategies are unique and can be fulfilled online with high enrichment factors (87-114) and high recoveries (81.14-110.94%). The method has been successively applied to the determination of Alternaria mycotoxins in real apple juice and wine samples with the limits of detection (LOD) in the range of 0.03-0.14μgL(-1). Totally 12 wine samples and 15 apple juice samples from the local market were analyzed. The detection rate of AOH and AME in both kinds of the samples were more than 50%, while TeA was found in relatively high level of 1.75-49.61μgL(-1) in some of the apple juice samples. The proposed method is simple, rapid, and sensitive and could also be used for the analysis and monitoring of Alternaria mycotoxin in other food samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Column Chromatography To Obtain Organic Cation Sorption Isotherms.

    Science.gov (United States)

    Jolin, William C; Sullivan, James; Vasudevan, Dharni; MacKay, Allison A

    2016-08-02

    Column chromatography was evaluated as a method to obtain organic cation sorption isotherms for environmental solids while using the peak skewness to identify the linear range of the sorption isotherm. Custom packed HPLC columns and standard batch sorption techniques were used to intercompare sorption isotherms and solid-water sorption coefficients (Kd) for four organic cations (benzylamine, 2,4-dichlorobenzylamine, phenyltrimethylammonium, oxytetracycline) with two aluminosilicate clay minerals and one soil. A comparison of Freundlich isotherm parameters revealed isotherm linearity or nonlinearity was not significantly different between column chromatography and traditional batch experiments. Importantly, skewness (a metric of eluting peak symmetry) analysis of eluting peaks can establish isotherm linearity, thereby enabling a less labor intensive means to generate the extensive data sets of linear Kd values required for the development of predictive sorption models. Our findings clearly show that column chromatography can reproduce sorption measures from conventional batch experiments with the benefit of lower labor-intensity, faster analysis times, and allow for consistent sorption measures across laboratories with distinct chromatography instrumentation.

  4. Determination of the Antibiotic Oxytetracycline in Commercial Milk by Solid-Phase Extraction: A High-Performance Liquid Chromatography (HPLC) Experiment for Quantitative Instrumental Analysis

    Science.gov (United States)

    Mei-Ratliff, Yuan

    2012-01-01

    Trace levels of oxytetracylcine spiked into commercial milk samples are extracted, cleaned up, and preconcentrated using a C[subscript 18] solid-phase extraction column. The extract is then analyzed by a high-performance liquid chromatography (HPLC) instrument equipped with a UV detector and a C[subscript 18] column (150 mm x 4.6 mm x 3.5 [mu]m).…

  5. Instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-15

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  6. Instrumental analysis

    International Nuclear Information System (INIS)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-01

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  7. Radioactive standards and calibration methods for contamination monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Makoto [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-06-01

    Contamination monitoring in the facilities for handling unsealed radioactive materials is one of the most important procedures for radiation protection as well as radiation dose monitoring. For implementation of the proper contamination monitoring, radiation measuring instruments should not only be suitable to the purpose of monitoring, but also be well calibrated for the objective qualities of measurement. In the calibration of contamination monitoring instruments, quality reference activities need to be used. They are supplied in different such as extended sources, radioactive solutions or radioactive gases. These reference activities must be traceable to the national standards or equivalent standards. On the other hand, the appropriate calibration methods must be applied for each type of contamination monitoring instruments. In this paper, the concepts of calibration for contamination monitoring instruments, reference sources, determination methods of reference quantities and practical calibration methods of contamination monitoring instruments, including the procedures carried out in Japan Atomic Energy Research Institute and some relevant experimental data. (G.K.)

  8. Maximizing kinetic performance in supercritical fluid chromatography using state-of-the-art instruments.

    Science.gov (United States)

    Grand-Guillaume Perrenoud, Alexandre; Hamman, Chris; Goel, Meenakshi; Veuthey, Jean-Luc; Guillarme, Davy; Fekete, Szabolcs

    2013-11-01

    Recently, there has been a renewed interest in supercritical fluid chromatography (SFC), due to the introduction of state-of-the-art instruments and dedicated columns packed with small particles. However, the achievable kinetic performance and practical possibilities of such modern SFC instruments and columns has not been described in details until now. The goal of the present contribution was to provide some information about the optimal column dimensions (i.e. length, diameter and particle size) suitable for such state-of the-art systems, with respect to extra-column band broadening and system upper pressure limit. In addition, the reliability of the kinetic plot methodology, successfully applied in RPLC, was also evaluated under SFC conditions. Taking into account the system variance, measured at ∼85μL(2), on modern SFC instruments, a column of 3mm I.D. was ideally suited for the current technology, as the loss in efficiency remained reasonable (i.e. less than 10% decrease for k>6). Conversely, these systems struggle with 2.1mm I.D. columns (55% loss in N for k=5). Regarding particle size, columns packed with 5μm particles provided unexpectedly high minimum reduced plate height values (hmin=3.0-3.4), while the 3.5 and 1.7μm packing provided lower reduced plate heights hmin=2.2-2.4 and hmin=2.7-3.2, respectively. Considering the system upper pressure limit, it appears that columns packed with 1.7μm particles give the lowest analysis time for efficiencies up to 40,000-60,000 plates, if the mobile phase composition is in the range of 2-19% MeOH. The 3.5μm particles were attractive for higher efficiencies, particularly when the modifier percentage was above 20%, while 5μm was never kinetically relevant with modern SFC instruments, due to an obvious limitation in terms of upper flow rate value. The present work also confirms that the kinetic plot methodology could be successfully applied to SFC, without the need for isopycnic measurements, as the difference

  9. Approaches for on-line coupling of extraction and chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Hyoetylaeinen, Tuulia; Riekkola, Marja-Liisa [Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, 00014, Helsinki (Finland)

    2004-04-01

    This review provides an overview of the approaches available in order to perform on-line coupling of various extraction techniques with liquid and gas chromatography, for the analysis of semivolatile and nonvolatile analytes in liquid and solid samples. The main focus is on the instrumental set-up of these techniques. Selected real applications are described by way of illustration. The extraction methods suitable for on-line coupling covered in this review are: liquid-liquid extraction, solid-phase extraction, membrane-based techniques, pressurised liquid extraction, supercritical fluid extraction, and microwave- and sonication-assisted extractions. The following systems are not covered in this review: on-line coupled solid-phase extraction-liquid chromatography, purge-and-trap-GC, and membrane extraction with a sorbent interface-GC. (orig.)

  10. Quantitative analysis of abused drugs in physiological fluids by gas chromatography/chemical ionization mass spectrometry

    International Nuclear Information System (INIS)

    Foltz, R.L.

    1978-01-01

    Methods have been developed for quantitative analysis of commonly abused drugs in physiological fluids using gas chromatography/chemical ionization mass spectrometry. The methods are being evaluated in volunteer analytical and toxicological laboratories, and analytical manuals describing the methods are being prepared. The specific drug and metabolites included in this program are: Δ 9 -tetrahydrocannabinol, methadone, phencyclidine, methaqualone, morphine, amphetamine, methamphetamine, mescaline, 2,5-dimethoxy-4-methyl amphetamine, cocaine, benzoylecgonine, diazepam, and N-desmethyldiazepam. The current analytical methods utilize relatively conventional instrumentation and procedures, and are capable of measuring drug concentrations as low as 1 ng/ml. Various newer techniques such as sample clean-up by high performance liquid chromatography, separation by glass capillary chromatography, and ionization by negative ion chemical ionization are being investigated with respect to their potential for achieving higher sensitivity and specificity, as well as their ability to facilitate simultaneous analysis of more than one drug and metabolite. (Auth.)

  11. Preparative supercritical fluid chromatography: A powerful tool for chiral separations.

    Science.gov (United States)

    Speybrouck, David; Lipka, Emmanuelle

    2016-10-07

    In 2012, the 4 biggest pharmaceutical blockbusters were pure enantiomers and separating racemic mixtures is now frequently a key step in the development of a new drug. For a long time, preparative liquid chromatography was the technique of choice for the separation of chiral compounds either during the drug discovery process to get up to a hundred grams of a pure enantiomer or during the clinical trial phases needing kilograms of material. However the advent of supercritical Fluid Chromatography (SFC) in the 1990s has changed things. Indeed, the use of carbon dioxide as the mobile phase in SFC offers many advantages including high flow rate, short equilibration time as well as low solvent consumption. Despite some initial teething troubles, SFC is becoming the primary method for preparative chiral chromatography. This article will cover recent developments in preparative SFC for the separation of enantiomers, reviewing several aspects such as instrumentation, chiral stationary phases, mobile phases or purely preparative considerations including overloading, productivity or large scale chromatography. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. 21 CFR 862.2250 - Gas liquid chromatography system for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid chromatography system for clinical use is a device intended to separate one or more drugs or compounds from a...

  13. Development of an on-line mixed-mode gel liquid chromatography×reversed phase liquid chromatography method for separation of water extract from Flos Carthami.

    Science.gov (United States)

    Wang, Yu-Qing; Tang, Xu; Li, Jia-Fu; Wu, Yun-Long; Sun, Yu-Ying; Fang, Mei-Juan; Wu, Zhen; Wang, Xiu-Min; Qiu, Ying-Kun

    2017-10-13

    A novel on-line comprehensive two-dimensional liquid chromatography (2D-LC) method by coupling mixed-mode gel liquid chromatography (MMG-LC) with reversed phase liquid chromatography (RPLC) was developed. A mixture of 17 reference compounds was used to study the separation mechanism. A crude water extract of Flos Carthami was applied to evaluate the performance of the novel 2D-LC system. In the first dimension, the extract was eluted with a gradient of water/methanol over a cross-linked dextran gel Sephadex LH-20 column. Meanwhile, the advantages of size exclusion, reversed phase partition and adsorption separation mechanism were exploited before further on-line reversed phase purification on the second dimension. This novel on-line mixed-mode Sephadex LH-20×RPLC method provided higher peak resolution, sample processing ability (2.5mg) and better orthogonality (72.9%) versus RPLC×RPLC and hydrophilic interaction liquid chromatography (HILIC)×RPLC. To the best of our knowledge, this is the first report of a mixed-mode Sephadex LH-20×RPLC separation method with successful applications in on-line mode, which might be beneficial for harvesting targets from complicated medicinal plants. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Airtight miniaturized chromatography: a safer method for radiopharmaceutical quality control

    International Nuclear Information System (INIS)

    Coupal, J.J.; Shih, W.J.; Ryo, U.Y.

    1988-01-01

    Miniaturized chromatography is widely used for quality control of radiopharmaceuticals. Recently, published chromatography procedures have illustrated or described chromatography chambers open to the air in use, suggesting that volatile toxic mobile phases are harmless to people in the vicinity. The authors describe the results of their search for an inexpensive closed chromatography chamber that can be used to derive safely the benefits from conventional miniaturized chromatography

  15. The analysis of carbohydrates in milk powder by a new "heart-cutting" two-dimensional liquid chromatography method.

    Science.gov (United States)

    Ma, Jing; Hou, Xiaofang; Zhang, Bing; Wang, Yunan; He, Langchong

    2014-03-01

    In this study, a new"heart-cutting" two-dimensional liquid chromatography method for the simultaneous determination of carbohydrate contents in milk powder was presented. In this two dimensional liquid chromatography system, a Venusil XBP-C4 analysis column was used in the first dimension ((1)D) as a pre-separation column, a ZORBAX carbohydrates analysis column was used in the second dimension ((2)D) as a final-analysis column. The whole process was completed in less than 35min without a particular sample preparation procedure. The capability of the new two dimensional HPLC method was demonstrated in the determination of carbohydrates in various brands of milk powder samples. A conventional one dimensional chromatography method was also proposed. The two proposed methods were both validated in terms of linearity, limits of detection, accuracy and precision. The comparison between the results obtained with the two methods showed that the new and completely automated two dimensional liquid chromatography method is more suitable for milk powder sample because of its online cleanup effect involved. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  16. 21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...

  17. Application of gas chromatography to the investigations on polypropylene radiolysis

    International Nuclear Information System (INIS)

    Zagorski, Z.P.; Gluszewski, W.

    2006-01-01

    Refinement of the gas chromatography (GC) instrumental approach permitted not only improvement of investigation in basic research, but also development of a new kind of polypropylene blends, more suitable for the production of medical devices and radiation sterilization. It has been shown, that using the GC method not only methane and carbon dioxide can be measured, but also the consumption of oxygen which reacts with free radicals on the polypropylene chain

  18. Thin-layer and paper chromatography

    International Nuclear Information System (INIS)

    Sherma, J.

    1986-01-01

    This selective review covers the literature of thin-layer chromatography (TLC) and paper chromatography (PC) cited in Chemical Abstracts from December 5, 1983, through November 25, 1985, and Analytical Abstracts from November 1983 to November 1985. Also researched directly were the following important journals publishing papers on TLC and PC: the Journal of Chromatography (including its bibliography issues), Journal of High Resolution Chromatography and Chromatography Communications, Journal of Chromatographic Science, Chromatographia, Analytical Chemistry, JAOAC, and the special TLC issues of the Journal of Liquid Chromatography. Many of the inherent advantages of TLC that are obvious to workers familiar with high performance, quantitative theory and practice still are not appreciated adequately by the majority of people using chromatography. These include unrestricted access to the separation process; introducing magnetic, thermal, electrical, and other physical forces to improve resolution; high sample throughput; truly multidimensional separations; and the use of controlled multiple gradients. Many advantages of TLC relative to column chromatography were discussed in the Introductions to our 1982 and 1984 reviews of TLC in this Journal. No complete commercial robotics system specifically for TLC has been developed, but all necessary modules are available for such a system. The combination of robotics, with the continued development of theory, practice, and instrumentation will lead eventually to TLC systems that are unrivaled for speed, versatility, accuracy, precision, and sensitivity. 573 references

  19. Robotic thin layer chromatography instrument for synthetic chemistry

    International Nuclear Information System (INIS)

    Corkan, L.A.; Lindsey, J.S.

    1990-01-01

    One of our long-term goals is to develop robotic workstations for automated synthetic chemistry. Toward that goal we have constructed a 2nd generation instrument for performing TLC analysis. TLC has important advantages (over HPLC and GC) in analysis of crude reaction samples and parallel sample development. The TLC instrument consist of four dedicated stations for (1) plate dispensing, (2) sample application, (3) plate development, and (4) plate densitometry. A robot is used to move plates among stations. The combination of fixed automation and robotics gives high sample throughout (up to 10 samples per hour). A second robot performs reaction chemistry and feeds samples to the TLC instrument, thus enabling TLC analysis at the same time as synthetic reactions proceed on the workstation

  20. Column chromatography isolation of nicotine from tobacco leaf extract (Nicotiana tabaccum L.)

    Science.gov (United States)

    Fathi, Raden Muhammad; Fauzantoro, Ahmad; Rahman, Siti Fauziyah; Gozan, Misri

    2018-02-01

    Restrictions on the use of dried tobacco leaf for cigarette production must be accompanied by the development of non-cigarette alternative products that are made from tobacco leaves. One of the alternative that can be done is to use the nicotine compound in tobacco leaf extract as medical product, such as Parkinson's medication or to be used as active substance in biopesticide. Nicotine was isolated using column chromatography method with the variation of mobile phase mixture ratio (petroleum ether and ethanol), started from 8:2, 6:4, 4:6, 2:8, to 0:10. All of the chromatographic fraction from each mobile phase's ratio was then tested qualitatively using thin layer chromatography (TLC) and also quantitatively using HPLC instrument. The column chromatography process could isolate 4.006% of nicotine compound from 4.19% tobacco leaf extract's nicotine. It is also known that ethanol is a good solution to be used as chromatography's mobile phase for nicotine isolation from tobacco leaf extract.

  1. Trace analysis of halogenated hydrocarbons in gaseous samples by on-line enrichment in an adsorption trap, on-column cold-trapping and capillary gas chromatography. I.Method and instrumentation

    NARCIS (Netherlands)

    Noij, T.H.M.; Fabian, P.; Borchers, R.; Janssen, F.; Cramers, C.A.M.G.; Rijks, J.A.

    1987-01-01

    A method is described for the determination of halocarbons in gaseous samples down to the ppt level (1:1012, v/v), consisting of successive on-line sub-ambient enrichment on an adsorbent, on-column cryofocusing, capillary gas chromatography and electron-capture detection. The quantitative aspects of

  2. A novel liquid chromatography method using diode-array detector for the determination of oleuropein in dietary supplements.

    Science.gov (United States)

    Bertolini, Tiziana; Vicentini, Lorenza; Boschetti, Silvia; Andreatta, Paolo; Gatti, Rita

    2016-09-10

    A simple and fast chromatographic method using ultraviolet diode-array detector (UV-DAD) was developed for the automatic high performance liquid chromatography (HPLC) determination of the title of oleuropein in a new dietary supplements in form of effervescent granules. The chromatographic separations were performed on a C18 core-shell column with detection at λ=232nm. The mobile phase consisted of deionized water with 0.1% TFA and acetonitrile under gradient conditions at a flow-rate of 0.8mL/min. Oleuropein and oleuroside present in the raw material were characterized by high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). The validation of the analytical procedure has been performed determining the following parameters: specificity, linearity, repeatability, reproducibility, accuracy, limit of quantification (LOQ), stability of the standard and sample solutions. Linear response was observed in fortified placebo solutions (determination coefficient: 0.9998). Intra-day precision (relative standard deviation, RSD) was ≤5.0% for peak area and for retention times (tR) without significant differences between intra- and inter-day data. The limits of quantitation (LOQ) was about 5μg/mL and 9pmol/inject. Oleuropein recovery studies gave good results (99.9%) with a R.S.D. of 0.5%. The speed of analysis and the stability of the solutions with a fluctuation Δ (%) ≤2.0 at room temperature means an undoubted advantage of the method allowing the simultaneous preparation of many samples and consecutive chromatographic analyses by using an autosampler. The developed method is suitable for the quality control of oleuropein in raw material and industrial products. The method can be applied in any analytical laboratory not requiring a sophisticated instrumentation. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Comparative determination of phenytoin by spectrophotometry, gas chromatography, liquid chromatography, enzyme immunoassay, and radioimmunoassay

    International Nuclear Information System (INIS)

    Castro, A.; Ibanez, J.; DiCesare, J.L.; Adams, R.F.; Malkus, H.

    1978-01-01

    Sera from patients being treated with phenytoin were analyzed for the drug by spectrophotometry, gas chromatography, radioimmunoasay, enzyme immunoassay, and liquid chromatography. The assay values obtained were intercompared statistically. Enzyme immunoassay and liquid chromatography appear to be attractive alternatives to the more traditional methods of spectrophotometry and gas chromatography. Our radioimmunoassay data correlated poorly with results by the four other methods

  4. Methods of analysis-Determination of pesticides in sediment using gas chromatography/mass spectrometry

    Science.gov (United States)

    Hladik, Michelle; McWayne, Megan M.

    2012-01-01

    A method for the determination of 119 pesticides in environmental sediment samples is described. The method was developed by the U.S. Geological Survey (USGS) in support of the National Water Quality Assessment (NAWQA) Program. The pesticides included in this method were chosen through prior prioritization. Herbicides, insecticides, and fungicides along with degradates are included in this method and span a variety of chemical classes including, but not limited to, chloroacetanilides, organochlorines, organophosphates, pyrethroids, triazines, and triazoles. Sediment samples are extracted by using an accelerated solvent extraction system (ASE®, and the compounds of interest are separated from co-extracted matrix interferences (including sulfur) by passing the extracts through high performance liquid chromatography (HPLC) with gel-permeation chromatography (GPC) along with the use of either stacked graphitized carbon and alumina solid-phase extraction (SPE) cartridges or packed Florisil®. Chromatographic separation, detection, and quantification of the pesticides from the sediment-sample extracts are done by using gas chromatography with mass spectrometry (GC/MS). Recoveries in test sediment samples fortified at 10 micrograms per kilogram (μg/kg) dry weight ranged from 75 to 102 percent; relative standard deviations ranged from 3 to 13 percent. Method detection limits (MDLs), calculated by using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), ranged from 0.6 to 3.4 μg/kg dry weight.

  5. Application of Instrumented Charpy Method in Characterisation of Materials

    Directory of Open Access Journals (Sweden)

    Željko Alar

    2015-07-01

    Full Text Available Testing of absorbed impact energy according to the Charpy method is carried out to determine the behaviour of a material under the impact load. Instrumented Charpy method allows getting the force displacement curve through the entire test, That curve can be related to force-displacement curve which is obtained by the static tensile test. The purpose of this study was to compare the results of forces obtained by the static tensile test with the forces obtained by the instrumented Charpy method. Experimental part of the work contains testing of the mechanical properties of S275J0 steel by the static tensile test and Impact test on instrumented Charpy pendulum.

  6. Determination of thyroid hormones in mouse tissues by isotope-dilution microflow liquid chromatography-mass spectrometry method.

    Science.gov (United States)

    De Angelis, Meri; Giesert, Florian; Finan, Brian; Clemmensen, Christoffer; Müller, Timo D; Vogt-Weisenhorn, Daniela; Tschöp, Matthias H; Schramm, Karl-Werner

    2016-10-15

    Thyroid hormones (THs) play a critical role in the regulation of many biological processes such as growth, metabolism and development both in humans and wildlife. In general, TH levels are measured by immunoassay (IA) methods but the specificity of the antibodies used in these assays limits selectivity. In the last decade, several analytical methods using liquid chromatography-mass spectrometry (LC-MS) and tandem mass spectrometry (LC-MS/MS) have been developed to measure THs. These new techniques proved to be more accurate than the IA analysis and they were widely used for the determination of TH level in different human and animal tissues. A large part of LC-MS/MS methods described in literature employed between 200 and 500mg of sample, however this quantity can be considered too high especially when preclinical studies are conducted using mice as test subjects. Thus an analytical method that reduces the amount of tissue is essential. In this study, we developed a procedure for the analysis of six THs; L-thyroxine (T4), 3,3',5-triiodo-l-thyronine (T3), 3,3',5'-triiodo-l-thyronine (rT3), 3,5-diiodo-l-thyronine (rT2), 3,3'-diiodo-l-thyronine (T2), 3-iodo-l-thyronine (T1) using isotope ((13)C6-T4, (13)C6-T3, (13)C6-rT3, (13)C6-T2) dilution liquid chromatography-mass spectrometry. The major difference with previously described methods lies in the utilization of a nano-UPLC (Ultra Performance Liquid Chromatography) system in micro configuration. This approach leads to a reduction compared to the published methods, of column internal diameter, flow rate, and injected volume. The result of all these improvements is a decrease in the amount of sample necessary for the analysis. The method was tested on six different mouse tissues: liver, heart, kidney, muscle, lung and brown adipose tissue (BAT). The nano-UPLC system was interfaced with a quadrupole time-of-flight mass spectrometer (Q-TOF2-MS) using the positive ion mode electrospray ionization. In our analytical method

  7. Determination of Urine Albumin by New Simple High-Performance Liquid Chromatography Method.

    Science.gov (United States)

    Klapkova, Eva; Fortova, Magdalena; Prusa, Richard; Moravcova, Libuse; Kotaska, Karel

    2016-11-01

    A simple high-performance liquid chromatography (HPLC) method was developed for the determination of albumin in patients' urine samples without coeluting proteins and was compared with the immunoturbidimetric determination of albumin. Urine albumin is important biomarker in diabetic patients, but part of it is immuno-nonreactive. Albumin was determined by high-performance liquid chromatography (HPLC), UV detection at 280 nm, Zorbax 300SB-C3 column. Immunoturbidimetric analysis was performed using commercial kit on automatic biochemistry analyzer COBAS INTEGRA ® 400, Roche Diagnostics GmbH, Manheim, Germany. The HLPC method was fully validated. No significant interference with other proteins (transferrin, α-1-acid glycoprotein, α-1-antichymotrypsin, antitrypsin, hemopexin) was found. The results from 301 urine samples were compared with immunochemical determination. We found a statistically significant difference between these methods (P = 0.0001, Mann-Whitney test). New simple HPLC method was developed for the determination of urine albumin without coeluting proteins. Our data indicate that the HPLC method is highly specific and more sensitive than immunoturbidimetry. © 2016 Wiley Periodicals, Inc.

  8. A high pressure liquid chromatography method for separation of prolactin forms.

    Science.gov (United States)

    Bell, Damon A; Hoad, Kirsten; Leong, Lillian; Bakar, Juwaini Abu; Sheehan, Paul; Vasikaran, Samuel D

    2012-05-01

    Prolactin has multiple forms and macroprolactin, which is thought not to be bioavailable, can cause a raised serum prolactin concentration. Gel filtration chromatography (GFC) is currently the gold standard method for separating macroprolactin, but is labour-intensive. Polyethylene glycol (PEG) precipitation is suitable for routine use but may not always be accurate. We developed a high pressure liquid chromatography (HPLC) assay for macroprolactin measurement. Chromatography was carried out using an Agilent Zorbax GF-250 (9.4 × 250 mm, 4 μm) size exclusion column and 50 mmol/L Tris buffer with 0.15 mmol/L NaCl at pH 7.2 as mobile phase, with a flow rate of 1 mL/min. Serum or plasma was diluted 1:1 with mobile phase and filtered and 100 μL injected. Fractions of 155 μL were collected for prolactin measurement and elution profile plotted. The area under the curve of each prolactin peak was calculated to quantify each prolactin form, and compared with GFC. Clear separation of monomeric-, big- and macroprolactin forms was achieved. Quantification was comparable to GFC and precision was acceptable. Total time from injection to collection of the final fraction was 16 min. We have developed an HPLC method for quantification of macroprolactin, which is rapid and easy to perform and therefore can be used for routine measurement.

  9. Evaluation between ultrahigh pressure liquid chromatography and high-performance liquid chromatography analytical methods for characterizing natural dyestuffs.

    Science.gov (United States)

    Serrano, Ana; van Bommel, Maarten; Hallett, Jessica

    2013-11-29

    An evaluation was undertaken of ultrahigh pressure liquid chromatography (UHPLC) in comparison to high-performance liquid chromatography (HPLC) for characterizing natural dyes in cultural heritage objects. A new UHPLC method was optimized by testing several analytical parameters adapted from prior UHPLC studies developed in diverse fields of research. Different gradient elution programs were tested on seven UHPLC columns with different dimensions and stationary phase compositions by applying several mobile phases, flow rates, temperatures, and runtimes. The UHPLC method successfully provided more improved data than that achieved by the HPLC method. Indeed, even though carminic acid has shown circa 146% higher resolution with HPLC, UHPLC resulted in an increase of 41-61% resolution and a decrease of 91-422% limit of detection, depending on the dye compound. The optimized method was subsequently assigned to analyse 59 natural reference materials, in which 85 different components were ascribed with different physicochemical properties, in order to create a spectral database for future characterization of dyes in cultural heritage objects. The majority of these reference samples could be successfully distinguished with one single method through the examination of these compounds' retention times and their spectra acquired with a photodiode array detector. These results demonstrate that UHPLC analyses are extremely valuable for the acquisition of more precise chromatographic information concerning natural dyes with complex mixtures of different and/or closely related physicochemical properties, essential for distinguishing similar species of plants and animals used to colour cultural heritage objects. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. A simplified method for rapid quantification of intracellular nucleoside triphosphates by one-dimensional thin-layer chromatography

    DEFF Research Database (Denmark)

    Jendresen, Christian Bille; Kilstrup, Mogens; Martinussen, Jan

    2011-01-01

    -pyrophosphate (PRPP), and inorganic pyrophosphate (PPi) in cell extracts. The method uses one-dimensional thin-layer chromatography (TLC) and radiolabeled biological samples. Nucleotides are resolved at the level of ionic charge in an optimized acidic ammonium formate and chloride solvent, permitting...... quantification of NTPs. The method is significantly simpler and faster than both current two-dimensional methods and high-performance liquid chromatography (HPLC)-based procedures, allowing a higher throughput while common sources of inaccuracies and technical problems are avoided. For determination of PPi...

  11. Application of Instrumented Charpy Method in Characterisation of Materials

    OpenAIRE

    Alar, Željko; Mandić, Davor; Dugorepec, Andrija; Sakoman, Matija

    2015-01-01

    Testing of absorbed impact energy according to the Charpy method is carried out to determine the behaviour of a material under the impact load. Instrumented Charpy method allows getting the force displacement curve through the entire test, That curve can be related to force-displacement curve which is obtained by the static tensile test. The purpose of this study was to compare the results of forces obtained by the static tensile test with the forces obtained by the instrumented Charpy method...

  12. Development of a sensitive and rapid method for rifampicin impurity analysis using supercritical fluid chromatography.

    Science.gov (United States)

    Li, Wei; Wang, Jun; Yan, Zheng-Yu

    2015-10-10

    A novel simple, fast and efficient supercritical fluid chromatography (SFC) method was developed and compared with RPLC method for the separation and determination of impurities in rifampicin. The separation was performed using a packed diol column and a mobile phase B (modifier) consisting of methanol with 0.1% ammonium formate (w/v) and 2% water (v/v). Overall satisfactory resolutions and peak shapes for rifampicin quinone (RQ), rifampicin (RF), rifamycin SV (RSV), rifampicin N-oxide (RNO) and 3-formylrifamycinSV (3-FR) were obtained by optimization of the chromatography system. With gradient elution of mobile phase, all of the impurities and the active were separated within 4 min. Taking full advantage of features of SFC (such as particular selectivity, non-sloping baseline in gradient elution, and without injection solvent effects), the method was successfully used for determination of impurities in rifampicin, with more impurity peaks detected, better resolution achieved and much less analysis time needed compared with conventional reversed-phase liquid chromatography (RPLC) methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Establishment of analysis method for methane detection by gas chromatography

    Science.gov (United States)

    Liu, Xinyuan; Yang, Jie; Ye, Tianyi; Han, Zeyu

    2018-02-01

    The study focused on the establishment of analysis method for methane determination by gas chromatography. Methane was detected by hydrogen flame ionization detector, and the quantitative relationship was determined by working curve of y=2041.2x+2187 with correlation coefficient of 0.9979. The relative standard deviation of 2.60-6.33% and the recovery rate of 96.36%∼105.89% were obtained during the parallel determination of standard gas. This method was not quite suitable for biogas content analysis because methane content in biogas would be over the measurement range in this method.

  14. An optimized method for the measurement of acetaldehyde by high-performance liquid chromatography.

    Science.gov (United States)

    Guan, Xiangying; Rubin, Emanuel; Anni, Helen

    2012-03-01

    Acetaldehyde is produced during ethanol metabolism predominantly in the liver by alcohol dehydrogenase and rapidly eliminated by oxidation to acetate via aldehyde dehydrogenase. Assessment of circulating acetaldehyde levels in biological matrices is performed by headspace gas chromatography and reverse phase high-performance liquid chromatography (RP-HPLC). We have developed an optimized method for the measurement of acetaldehyde by RP-HPLC in hepatoma cell culture medium, blood, and plasma. After sample deproteinization, acetaldehyde was derivatized with 2,4-dinitrophenylhydrazine (DNPH). The reaction was optimized for pH, amount of derivatization reagent, time, and temperature. Extraction methods of the acetaldehyde-hydrazone (AcH-DNP) stable derivative and product stability studies were carried out. Acetaldehyde was identified by its retention time in comparison with AcH-DNP standard, using a new chromatography gradient program, and quantitated based on external reference standards and standard addition calibration curves in the presence and absence of ethanol. Derivatization of acetaldehyde was performed at pH 4.0 with an 80-fold molar excess of DNPH. The reaction was completed in 40 minutes at ambient temperature, and the product was stable for 2 days. A clear separation of AcH-DNP from DNPH was obtained with a new 11-minute chromatography program. Acetaldehyde detection was linear up to 80 μM. The recovery of acetaldehyde was >88% in culture media and >78% in plasma. We quantitatively determined the ethanol-derived acetaldehyde in hepatoma cells, rat blood and plasma with a detection limit around 3 μM. The accuracy of the method was volume (70 μl) plasma sampling. An optimized method for the quantitative determination of acetaldehyde in biological systems was developed using derivatization with DNPH, followed by a short RP-HPLC separation of AcH-DNP. The method has an extended linear range, is reproducible and applicable to small-volume sampling of culture

  15. Overview of online two-dimensional liquid chromatography based on cell membrane chromatography for screening target components from traditional Chinese medicines.

    Science.gov (United States)

    Muhammad, Saqib; Han, Shengli; Xie, Xiaoyu; Wang, Sicen; Aziz, Muhammad Majid

    2017-01-01

    Cell membrane chromatography is a simple, specific, and time-saving technique for studying drug-receptor interactions, screening of active components from complex mixtures, and quality control of traditional Chinese medicines. However, the short column life, low sensitivity, low column efficiency (so cannot resolve satisfactorily mixture of compounds), low peak capacity, and inefficient in structure identification were bottleneck in its application. Combinations of cell membrane chromatography with multidimensional chromatography such as two-dimensional liquid chromatography and high sensitivity detectors like mass have significantly reduced many of the above-mentioned shortcomings. This paper provides an overview of the current advances in online two-dimensional-based cell membrane chromatography for screening target components from traditional Chinese medicines with particular emphasis on the instrumentation, preparation of cell membrane stationary phase, advantages, and disadvantages compared to alternative approaches. The last section of the review summarizes the applications of the online two-dimensional high-performance liquid chromatography based cell membrane chromatography reported since its emergence to date (2010-June 2016). © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Ion counting method and it's operational characteristics in gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Fujii, Toshihiro

    1976-01-01

    Ion counting method with continuous channel electron multiplier which affords the direct detection of very small ion currents and it's operational characteristics were studied in gas chromatography-mass spectrometry. Then this method was applied to the single ion detection technique of GC-MS. A detection limit was measured, using various standard samples of low level concentration. (auth.)

  17. Hydroxylapatite chromatography.

    Science.gov (United States)

    Broadhurst, A V

    2001-05-01

    Hydroxylapatite (also called hydroxyapatite), a form of calcium phosphate, can be used as a matrix for the chromatography of both proteins and nucleic acids. Protocols are provided for both standard low-pressure chromatography of a protein mixture using a hydroxylapatite column prepared in the laboratory, and an HPLC method, applicable to proteins and nucleic acids, that uses a commercially available column. Alternate protocols describe column chromatography using a step gradient or batch binding and step-gradient elution.

  18. Role of maintenance of analytical instruments in the proceedings of quality control laboratory

    International Nuclear Information System (INIS)

    Haribabu, A.; Sailoo, C.C.; Balaji Rao, Y.; Subba Rao, Y.

    2015-01-01

    Control Laboratory being a centralized analytical facility of Nuclear Fuel Complex (NFC) is engaged in chemical qualification of all nuclear materials processed/produced at NFC. The primary responsibility of control laboratory is to provide timely analytical results of raw materials, intermediates and final products to all the production plants of NFC for downstream processing. Annual analytical load of nearly five lakhs of estimations are being carried out at laboratory. For this purpose a gamut of analytical facilities ranging from classical methods like gravimetry, volumetry etc. to fully automated state-of-art analytical instruments like ICP-AES, Gas Analysers, Flame and Graphite Furnace-AAS, Direct Reading Emission Spectrometer (DRES), RF GD-OES, TIMS, WD-XRFS, ED-XRFS, Laser based PSD Analyser, Laser Fluorimeter, UV-Vis Spectrophotometer, Gamma Ray Spectrometer, Ion-Chromatography, Gas Chromatography are used to acquire analytical data to see the suitability of products for their intended use. Depending on the applications, analysts validate their procedures, calibrate their instruments, and perform additional instrument checks, such as system suitability tests and analysis of in-process quality control check samples. With the increasing sophistication and automation of analytical instruments, an increasing demand has been placed on maintenance engineers to qualify these instruments for the purpose

  19. Pre-validation methods for developing a patient reported outcome instrument

    Directory of Open Access Journals (Sweden)

    Castillo Mayret M

    2011-08-01

    Full Text Available Abstract Background Measures that reflect patients' assessment of their health are of increasing importance as outcome measures in randomised controlled trials. The methodological approach used in the pre-validation development of new instruments (item generation, item reduction and question formatting should be robust and transparent. The totality of the content of existing PRO instruments for a specific condition provides a valuable resource (pool of items that can be utilised to develop new instruments. Such 'top down' approaches are common, but the explicit pre-validation methods are often poorly reported. This paper presents a systematic and generalisable 5-step pre-validation PRO instrument methodology. Methods The method is illustrated using the example of the Aberdeen Glaucoma Questionnaire (AGQ. The five steps are: 1 Generation of a pool of items; 2 Item de-duplication (three phases; 3 Item reduction (two phases; 4 Assessment of the remaining items' content coverage against a pre-existing theoretical framework appropriate to the objectives of the instrument and the target population (e.g. ICF; and 5 qualitative exploration of the target populations' views of the new instrument and the items it contains. Results The AGQ 'item pool' contained 725 items. Three de-duplication phases resulted in reduction of 91, 225 and 48 items respectively. The item reduction phases discarded 70 items and 208 items respectively. The draft AGQ contained 83 items with good content coverage. The qualitative exploration ('think aloud' study resulted in removal of a further 15 items and refinement to the wording of others. The resultant draft AGQ contained 68 items. Conclusions This study presents a novel methodology for developing a PRO instrument, based on three sources: literature reporting what is important to patient; theoretically coherent framework; and patients' experience of completing the instrument. By systematically accounting for all items dropped

  20. Chromatography resin support

    Science.gov (United States)

    Dobos, James G.

    2002-01-01

    An apparatus and method of using an improved chromatography resin support is disclosed. The chromatography support platform is provided by a stainless steel hollow cylinder adapted for being inserted into a chromatography column. An exterior wall of the stainless steel cylinder defines a groove for carrying therein an "O"-ring. The upper surface of the stainless steel column is covered by a fine stainless steel mesh welded to the edges of the stainless steel cylinder. When placed upon a receiving ledge defined within a chromatography column, the "O"-ring provides a fluid tight seal with the inner edge wall of the chromatography cylinder. The stainless steel mesh supports the chromatography matrix and provides a back flushable support which is economical and simple to construct.

  1. Report: Affinity Chromatography.

    Science.gov (United States)

    Walters, Rodney R.

    1985-01-01

    Supports, affinity ligands, immobilization, elution methods, and a number of applications are among the topics considered in this discussion of affinity chromatography. An outline of the basic principles of affinity chromatography is included. (JN)

  2. Advanced Measuring (Instrumentation Methods for Nuclear Installations: A Review

    Directory of Open Access Journals (Sweden)

    Wang Qiu-kuan

    2012-01-01

    Full Text Available The nuclear technology has been widely used in the world. The research of measurement in nuclear installations involves many aspects, such as nuclear reactors, nuclear fuel cycle, safety and security, nuclear accident, after action, analysis, and environmental applications. In last decades, many advanced measuring devices and techniques have been widely applied in nuclear installations. This paper mainly introduces the development of the measuring (instrumentation methods for nuclear installations and the applications of these instruments and methods.

  3. Creating New Technologists of Research in the 1960s: The Case of the Reproduction of Automated Chromatography Specialists and Practitioners

    Science.gov (United States)

    Gerontas, Apostolos

    2014-08-01

    Chromatographic instrumentation has been really influential in shaping the modern chemical practice, and yet it has been largely overlooked by history of science.Gas chromatography in the 1960s was considered the analytical technique closer to becoming dominant, and being the first automated chromatography set the standards that all the subsequent chromatographic instrumentation had to fulfill. Networks of specialists, groups of actors, corporate strategies and the analytical practice itself, were all affected and in many ways because of the entrance of gas chromatography in the chemical laboratory and in the instrumentation market. This paper gives a view of the early history of the gas chromatography instrumentation, relates it to the broader research-technology phenomenon and discusses issues of education and group reproduction in the case of the groups of technologists of the era. The chaotic elements of knowledge transfer during the instrumentation revolution in chemistry are being highlighted and they are being connected to the observable radical innovation of the period.

  4. Pre-concentration technique for reduction in "Analytical instrument requirement and analysis"

    Science.gov (United States)

    Pal, Sangita; Singha, Mousumi; Meena, Sher Singh

    2018-04-01

    Availability of analytical instruments for a methodical detection of known and unknown effluents imposes a serious hindrance in qualification and quantification. Several analytical instruments such as Elemental analyzer, ICP-MS, ICP-AES, EDXRF, ion chromatography, Electro-analytical instruments which are not only expensive but also time consuming, required maintenance, damaged essential parts replacement which are of serious concern. Move over for field study and instant detection installation of these instruments are not convenient to each and every place. Therefore, technique such as pre-concentration of metal ions especially for lean stream elaborated and justified. Chelation/sequestration is the key of immobilization technique which is simple, user friendly, most effective, least expensive, time efficient; easy to carry (10g - 20g vial) to experimental field/site has been demonstrated.

  5. A Geometrical Method for Sound-Hole Size and Location Enhancement in Lute Family Musical Instruments: The Golden Method

    Directory of Open Access Journals (Sweden)

    Soheil Jafari

    2017-11-01

    Full Text Available This paper presents a new analytical approach, the Golden Method, to enhance sound-hole size and location in musical instruments of the lute family in order to obtain better sound damping characteristics based on the concept of the golden ratio and the instrument geometry. The main objective of the paper is to increase the capability of lute family musical instruments in keeping a note for a certain time at a certain level to enhance the instruments’ orchestral characteristics. For this purpose, a geometry-based analytical method, the Golden Method is first described in detail in an itemized feature. A new musical instrument is then developed and tested to confirm the ability of the Golden Method in optimizing the acoustical characteristics of musical instruments from a damping point of view by designing the modified sound-hole. Finally, the new-developed instrument is tested, and the obtained results are compared with those of two well-known instruments to confirm the effectiveness of the proposed method. The experimental results show that the suggested method is able to increase the sound damping time by at least 2.4% without affecting the frequency response function and other acoustic characteristics of the instrument. This methodology could be used as the first step in future studies on design, optimization and evaluation of musical instruments of the lute family (e.g., lute, oud, barbat, mandolin, setar, and etc..

  6. Application of partition chromatography method for separation and analysis of actinium radionuclides

    International Nuclear Information System (INIS)

    Sinitsina, G.S.; Shestakova, I.A.; Shestakov, B.I.; Plyushcheva, N.A.; Malyshev, N.A.; Belyatskij, A.F.; Tsirlin, V.A.

    1979-01-01

    The method of partition chromatography is considered with the use of different extractants for the extraction of actinium-227, actinium-225 and actinium-228. It is advisable to extract actinium-227 from the irradiated radium with the help of D2FGFK. The use of 2DEGFK allows us to separate actinium-227 from alkaline and alkaline-earth elements. Amines have a higher radiative stability. An express-method has been developed for the identification of actinium-227 with TOA by its intrinsic α-emission in nonequilibrium preparations of irradiated radium-226 of small activity. Actinium-225 is extracted from uranium-233 with due regard for the fact that U, Th, and Ac are extracted differently by TBP from HNO 3 solutions. With the help of the given procedure one can reach the purifying coefficient of 10 4 . Actinium-228 is extracted from the radiummesothorium preparations by a deposition of decay products, including polonium-210 on the iron hydroxyde. Actinium-228 extraction from the mixture of radium radionuclides is performed by the partition chromatography method on D2EGFK. All the procedures for separation of actinium isotopes by the above methods are described

  7. Simultaneous Determination of Caffeine and Vitamin B6 in Energy Drinks by High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Leacock, Rachel E.; Stankus, John J.; Davis, Julian M.

    2011-01-01

    A high-performance liquid chromatography experiment to determine the concentration of caffeine and vitamin B6 in sports energy drinks has been developed. This laboratory activity, which is appropriate for an upper-level instrumental analysis course, illustrates the standard addition method and simultaneous determination of two species. (Contains 1…

  8. Assessing the detectability of antioxidants in two-dimensional high-performance liquid chromatography.

    Science.gov (United States)

    Bassanese, Danielle N; Conlan, Xavier A; Barnett, Neil W; Stevenson, Paul G

    2015-05-01

    This paper explores the analytical figures of merit of two-dimensional high-performance liquid chromatography for the separation of antioxidant standards. The cumulative two-dimensional high-performance liquid chromatography peak area was calculated for 11 antioxidants by two different methods--the areas reported by the control software and by fitting the data with a Gaussian model; these methods were evaluated for precision and sensitivity. Both methods demonstrated excellent precision in regards to retention time in the second dimension (%RSD below 1.16%) and cumulative second dimension peak area (%RSD below 3.73% from the instrument software and 5.87% for the Gaussian method). Combining areas reported by the high-performance liquid chromatographic control software displayed superior limits of detection, in the order of 1 × 10(-6) M, almost an order of magnitude lower than the Gaussian method for some analytes. The introduction of the countergradient eliminated the strong solvent mismatch between dimensions, leading to a much improved peak shape and better detection limits for quantification. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Development of a new screening method for the detection of antibiotic residues in muscle tissues using liquid chromatography and high resolution mass spectrometry with a LC-LTQ-Orbitrap instrument.

    OpenAIRE

    2011-01-01

    Abstract In the present work, a liquid chromatography- high resolution mass spectrometry method was developed for the screening in meat of a wide range of antibiotics used in veterinary medicine. Full scan mode under high resolution mass spectral conditions using LTQ-Orbitrap mass spectrometer with resolving power 60.000 FWHM was applied for analysis of the samples. Samples were prepared using two extractions protocols prior to LC-MS analysis. The scope of the method focuses on the...

  10. Possibilities and limitations of the kinetic plot method in supercritical fluid chromatography.

    Science.gov (United States)

    De Pauw, Ruben; Desmet, Gert; Broeckhoven, Ken

    2013-08-30

    Although supercritical fluid chromatography (SFC) is becoming a technique of increasing importance in the field of analytical chromatography, methods to compare the performance of SFC-columns and separations in an unbiased way are not fully developed. The present study uses mathematical models to investigate the possibilities and limitations of the kinetic plot method in SFC as this easily allows to investigate a wide range of operating pressures, retention and mobile phase conditions. The variable column length (L) kinetic plot method was further investigated in this work. Since the pressure history is identical for each measurement, this method gives the true kinetic performance limit in SFC. The deviations of the traditional way of measuring the performance as a function of flow rate (fixed back pressure and column length) and the isopycnic method with respect to this variable column length method were investigated under a wide range of operational conditions. It is found that using the variable L method, extrapolations towards other pressure drops are not valid in SFC (deviation of ∼15% for extrapolation from 50 to 200bar pressure drop). The isopycnic method provides the best prediction but its use is limited when operating closer towards critical point conditions. When an organic modifier is used, the predictions are improved for both methods with respect to the variable L method (e.g. deviations decreases from 20% to 2% when 20mol% of methanol is added). Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Gas chromatography

    International Nuclear Information System (INIS)

    Cram, S.P.; Risby, T.H.; Field, L.R.; Yu, W.L.

    1980-01-01

    In addition to the published literature for the years 1978 - 79, this review of developments in the field of gas chromatography includes earlier articles of particular significance appearing in foreign journals and the patent literature which was not available at the time of the previous review. The articles cited were selected as presenting the most fundamental developments in theory, methodology, and instrumentation. Some applications are cited if they reflect an advance in the state-of-the-art or have particular relevance to new developments. 1149 references are cited

  12. Towards Chip Scale Liquid Chromatography and High Throughput Immunosensing

    Energy Technology Data Exchange (ETDEWEB)

    Ni, Jing [Iowa State Univ., Ames, IA (United States)

    2000-09-21

    This work describes several research projects aimed towards developing new instruments and novel methods for high throughput chemical and biological analysis. Approaches are taken in two directions. The first direction takes advantage of well-established semiconductor fabrication techniques and applies them to miniaturize instruments that are workhorses in analytical laboratories. Specifically, the first part of this work focused on the development of micropumps and microvalves for controlled fluid delivery. The mechanism of these micropumps and microvalves relies on the electrochemically-induced surface tension change at a mercury/electrolyte interface. A miniaturized flow injection analysis device was integrated and flow injection analyses were demonstrated. In the second part of this work, microfluidic chips were also designed, fabricated, and tested. Separations of two fluorescent dyes were demonstrated in microfabricated channels, based on an open-tubular liquid chromatography (OT LC) or an electrochemically-modulated liquid chromatography (EMLC) format. A reduction in instrument size can potentially increase analysis speed, and allow exceedingly small amounts of sample to be analyzed under diverse separation conditions. The second direction explores the surface enhanced Raman spectroscopy (SERS) as a signal transduction method for immunoassay analysis. It takes advantage of the improved detection sensitivity as a result of surface enhancement on colloidal gold, the narrow width of Raman band, and the stability of Raman scattering signals to distinguish several different species simultaneously without exploiting spatially-separated addresses on a biochip. By labeling gold nanoparticles with different Raman reporters in conjunction with different detection antibodies, a simultaneous detection of a dual-analyte immunoassay was demonstrated. Using this scheme for quantitative analysis was also studied and preliminary dose-response curves from an immunoassay of a

  13. Power plant instrumentation for measurement of high-purity water quality

    International Nuclear Information System (INIS)

    Brown, J.

    1981-01-01

    Work undertaken by Ontario Hydro, Toronto, to determine levels of feedwater impurities, including corrosion products and condenser cooling water in leakage contaminants, is reviewed. Corrosion product measurement using a grab method gave some useful data but was found to be too labor-intensive. Continuous analysis of corrosion products, in conjunction with a valveless capillary sampler, is now being evaluated as a method. Ion chromatography appears to be a promising technique to determine anions in feedwater. Tests to adapt such an instrument for continuous analysis are planned

  14. Calibration of shahid's analytical method for adulterated Zn-edta fertilizers by ion chromatography and atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Khan, M.S.A.; Akram, M.; Qazi, M.A.

    2010-01-01

    Chelated zinc fertilizers are usually recommended in calcareous alkaline soils to provide Zn nutrition in order to prevent possible Zn precipitation. In Punjab (Pakistan), Zn EDTA products are being manufactured, and marketed to meet the zinc requirement of various crops grown in Zn deficient soils. Under fertilizer control order, 1973 (amended), their quality has to be monitored by the Agriculture Department, Government of the Punjab. None of the traditional method was found suitable which can separate the mineral fraction from that of chelated adulterated fertilizer except for those methods based on ion chromatography. Calibration of ion chromatography method was carried out by determining the mineral Zn fraction leading to estimate remaining Zn EDTA fraction in fertilizer samples of adulterated nature i.e. mixture of chelated and mineral fraction. In order to achieve the objective atomic absorption spectroscopy was coupled with ion chromatography. The method offers a specific, reliable technique for determination of chelated zinc in fertilizers. In the first step chelation was broken down with concentrated sulphuric acid treatment and total zinc contents were determined by atomic absorption spectroscopy. In second step, non-chelated (mineral) portion of zinc was determined by ion chromatography using cation column and conductivity detector. Chelated zinc was calculated by subtracting non-chelated (mineral) fraction from total zinc contents. (author)

  15. Potential application of gas chromatography to the analysis of hydrogen isotopes

    International Nuclear Information System (INIS)

    Warner, D.K.; Sprague, R.E.; Bohl, D.R.

    1976-01-01

    Gas chromatography is used at Mound Laboratory for the analysis of hydrogen isotopic impurities in gas mixtures. This instrumentation was used to study the applicability of the gas chromatography technique to the determination of the major components of hydrogen isotopic gas mixtures. The results of this study, including chromatograms and precision data, are presented

  16. Investigating the Retention Mechanisms of Liquid Chromatography Using Solid-Phase Extraction Cartridges

    Science.gov (United States)

    O'Donnell, Mary E.; Musial, Beata A.; Bretz, Stacey Lowery; Danielson, Neil D.; Ca, Diep

    2009-01-01

    Liquid chromatography (LC) experiments for the undergraduate analytical laboratory course often illustrate the application of reversed-phase LC to solve a separation problem, but rarely compare LC retention mechanisms. In addition, a high-performance liquid chromatography instrument may be beyond what some small colleges can purchase. Solid-phase…

  17. Separation techniques: Chromatography

    Science.gov (United States)

    Coskun, Ozlem

    2016-01-01

    Chromatography is an important biophysical technique that enables the separation, identification, and purification of the components of a mixture for qualitative and quantitative analysis. Proteins can be purified based on characteristics such as size and shape, total charge, hydrophobic groups present on the surface, and binding capacity with the stationary phase. Four separation techniques based on molecular characteristics and interaction type use mechanisms of ion exchange, surface adsorption, partition, and size exclusion. Other chromatography techniques are based on the stationary bed, including column, thin layer, and paper chromatography. Column chromatography is one of the most common methods of protein purification. PMID:28058406

  18. Repairing method of color TV with measuring instrument

    International Nuclear Information System (INIS)

    1996-01-01

    This book concentrates on repairing method of color TV with measuring instrument, which deals with direction and sorts of measuring instrument for service, application and basic technique of an oscilloscope and a synchroscope, constituent of TV and wave reading, everything for test skill for service man, service technique by electronic voltmeter, service technique by sweep generator and maker generator, dot-bar generator and support skill for color TV and color bar generator and application technology of color circuit.

  19. Development and implementation of an electronic interface for complex clinical laboratory instruments without a vendor-provided data transfer interface

    Directory of Open Access Journals (Sweden)

    Gary E Blank

    2011-01-01

    Full Text Available Background: Clinical pathology laboratories increasingly use complex instruments that incorporate chromatographic separation, e.g. liquid chromatography, with mass detection for rapid identification and quantification of biochemicals, biomolecules, or pharmaceuticals. Electronic data management for these instruments through interfaces with laboratory information systems (LIS is not generally available from the instrument manufacturers or LIS vendors. Unavailability of a data management interface is a limiting factor in the use of these instruments in clinical laboratories where there is a demand for high-throughput assays with turn-around times that meet patient care needs. Materials and Methods: Professional society guidelines for design and transfer of data between instruments and LIS were used in the development and implementation of the interface. File transfer protocols and support utilities were written to facilitate transfer of information between the instruments and the LIS. An interface was created for liquid chromatography-tandem mass spectroscopy and inductively coupled plasma-mass spectroscopy instruments to manage data in the Sunquest® LIS. Results: Interface validation, implementation and data transfer fidelity as well as training of technologists for use of the interface was performed by the LIS group. The technologists were familiarized with the data verification process as a part of the data management protocol. The total time for the technologists for patient/control sample data entry, assay results data transfer, and results verification was reduced from approximately 20 s per sample to <1 s per sample. Sample identification, results data entry errors, and omissions were eliminated. There was electronic record of the technologist performing the assay runs and data management. Conclusions: Development of a data management interface for complex, chromatography instruments in clinical laboratories has resulted in rapid, accurate

  20. A fast isocratic liquid chromatography method for the quantification of xanthophylls and their stereoisomers.

    Science.gov (United States)

    Nimalaratne, Chamila; Lopes-Lutz, Daise; Schieber, Andreas; Wu, Jianping

    2015-12-01

    A fast isocratic liquid chromatography method was developed for the simultaneous quantification of eight xanthophylls (13-Z-lutein, 13'-Z-lutein, 13-Z-zeaxanthin, all-E-lutein, all-E-zeaxanthin, all-E-canthaxanthin, all-E-β-apo-8'-carotenoic acid ethyl ester and all-E-β-apo-8'-carotenal) within 12 min, compared to 90 min by the conventional high-performance liquid chromatography method. The separation was achieved on a YMC C30 reversed-phase column (100 mm x 2.0 mm; 3 μm) operated at 20°C using a methanol/tert-butyl methyl ether/water solvent system at a flow rate of 0.8 mL/min. The method was successfully applied to quantify lutein and zeaxanthin stereoisomers in egg yolk, raw and cooked spinach, and a dietary supplement. The method can be used for the rapid analysis of xanthophyll isomers in different food products and for quality control purposes. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Development of conjugate methods with gas chromatography for inorganic compounds analysis

    International Nuclear Information System (INIS)

    Baccan, N.

    1975-01-01

    The application of gas chromatography combined with mass spectrometry or with nuclear methods for the analysis of inorganic compounds is studied. The advantages of the use of a gas chromatograph coupled with a quadrupole mass spectrometer or with a high resolution radiation detector, are discussed. We also studied the formation and solvent extraction of metal chelates; an aliquot of the organic phase was directly injected into the gas chromatograph and the eluted compounds were detected by mass spectrometry or, when radioactive, by nuclear methods. (author)

  2. Validation of a confirmatory method for the determination of melamine in egg by gas chromatography-mass spectrometry and ultra-performance liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Xia Xi; Ding Shuangyang; Li Xiaowei; Gong Xiao; Zhang Suxia; Jiang Haiyang; Li Jiancheng; Shen Jianzhong

    2009-01-01

    A sensitive and reliable method was developed and validated for detection and confirmation of melamine in egg based on gas chromatography-mass spectrometry (GC-MS) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Trichloroacetic acid solution was used for sample extraction and precipitation of proteins. The aqueous extracts were subjected to solid-phase extraction by mixed-mode reversed-phase/strong cation-exchange cartridges. Using ultra-performance liquid chromatography and electrospray ionization in the positive ion mode, melamine was determined by LC-MS/MS, which was completed in 5 min for each injection. For the GC-MS analysis, extracted melamine was derivatized with N,O-bis(trimethylsilyl)trifluoracetamide prior to selected ion monitoring detection in electron impact mode. The average recovery of melamine from fortified samples ranged from 85.2% to 103.2%, with coefficients of variation lower than 12%. The limit of detection obtained by GC-MS and UPLC-MS/MS was 10 and 5 μg kg -1 , respectively. This validated method was successfully applied to the determination of melamine in real samples from market.

  3. Greening Reversed-Phase Liquid Chromatography Methods Using Alternative Solvents for Pharmaceutical Analysis

    Directory of Open Access Journals (Sweden)

    Moussa Yabré

    2018-05-01

    Full Text Available The greening of analytical methods has gained increasing interest in the field of pharmaceutical analysis to reduce environmental impacts and improve the health safety of analysts. Reversed-phase high-performance liquid chromatography (RP-HPLC is the most widely used analytical technique involved in pharmaceutical drug development and manufacturing, such as the quality control of bulk drugs and pharmaceutical formulations, as well as the analysis of drugs in biological samples. However, RP-HPLC methods commonly use large amounts of organic solvents and generate high quantities of waste to be disposed, leading to some issues in terms of ecological impact and operator safety. In this context, greening HPLC methods is becoming highly desirable. One strategy to reduce the impact of hazardous solvents is to replace classically used organic solvents (i.e., acetonitrile and methanol with greener ones. So far, ethanol has been the most often used alternative organic solvent. Others strategies have followed, such as the use of totally aqueous mobile phases, micellar liquid chromatography, and ionic liquids. These approaches have been well developed, as they do not require equipment investments and are rather economical. This review describes and critically discusses the recent advances in greening RP-HPLC methods dedicated to pharmaceutical analysis based on the use of alternative solvents.

  4. Establishing the analytical procedure for acetate in water by ion chromatography method

    International Nuclear Information System (INIS)

    Nguyen Thi Hong Thinh; Ha Lan Anh; Vo Thi Anh

    2015-01-01

    In recent studies of contamination sources of arsenic, ammonium, iron, organic carbon in groundwater, acetate is measured a lot because it is the main decomposition product of organic compounds from sediment into groundwater. In order to better support for the study of the origin and mobilization mechanism of the pollutants, acetate was studied analysis method in Isotopes Hydrology Laboratory using ion chromatography technique. Project Researchers used Ion Chromatography system - DX-600 including IonPac ICE-AS1 column for separating acetate and conductivity detector CD 25 to quantify acetate in water samples. The study results showed that project team has successfully developed analytical procedures of acetate in water with acetate’s retention time is 12 minutes, limit of detection (LOD) of the method was 0.01 ppm. The accuracy of the method was established by calculating the precision and bias of 10 analysis times of a standard sample at content levels 1 ppm and 8 ppm. The results of the 10 measurements are satisfiable about precision and bias with repeated standard deviation coefficient CVR were 1.3% and 0.2% and the recoveries R were 99.92% and 101.72%. (author)

  5. A high-throughput method for liquid chromatography-tandem mass spectrometry determination of plasma alkylresorcinols, biomarkers of whole grain wheat and rye intake

    DEFF Research Database (Denmark)

    Ross, Alastair B; Svelander, Cecilia; Savolainen, Otto I

    2016-01-01

    supported extraction methods for extracting alkylresorcinols from plasma and improved a normal-phase liquid chromatography coupled to a tandem mass spectrometer method to reduce sample analysis time. The method was validated and compared with gas chromatography-mass spectrometry analysis. Sample preparation...

  6. A fast, comprehensive screening method for doping agents in urine by gas chromatography-triple quadrupole mass spectrometry.

    Science.gov (United States)

    Van Eenoo, Peter; Van Gansbeke, Wim; De Brabanter, Nik; Deventer, Koen; Delbeke, Frans T

    2011-05-27

    The use of performance enhancing drugs in sports is prohibited. For the detection of misuse of such substances gas chromatography or liquid chromatography coupled to mass spectrometry are the most frequently used detection techniques. In this work the development and validation of a fast gas chromatography tandem mass spectrometric method for the detection of a wide range of doping agents is described. The method can determine 13 endogenous steroids (the steroid profile), 19-norandrosterone, salbutamol and 11-nor-Δ9-tetrahydrocannabinol.9carboxylic acid in the applicable ranges and to detect qualitatively over 140 substances in accordance with the minimum required performance levels of the World Anti-Doping Agency in 1ml of urine. The classes of substances included in the method are anabolic steroids, β2-agonists, stimulants, narcotics, hormone antagonists and modulators and beta-blockers. Moreover, using a short capillary column and hydrogen as a carrier gas the run time of the method is less than 8min. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. Matrix influences on the determination of common ions by using ion chromatography part 1--determination of inorganic anions.

    Science.gov (United States)

    Michalski, Rajmund; Lyko, Aleksandra; Kurzyca, Iwona

    2012-07-01

    Ion chromatography is the most popular instrumental analytical method used for the determination of anions and cations in water and wastewater. Isocratic ion chromatography with suppressed conductivity detection is frequently used in laboratories carrying out routine analyses of inorganic anions. The paper presents the results of the research into the influence of selected inorganic anions dominant in environmental samples (Cl(-), NO(3)(-), SO(4)(2-)) on the possibility of simultaneous determination of F(-), Cl(-), NO(2)(-), NO(3)(-), PO(4)(3-) and SO(4)(2-) with the application of this most popular ion chromatography type in standard separation conditions. Four Dionex and four Metrohm anion-exchange columns were tested in standard separation conditions recommended by their manufacturers with both standard solutions and environmental samples with complex matrix.

  8. Organic geochemistry and environmental instrumentation programs

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    The areas of research of the Organic Geochemistry Group include (1) computer-assisted gas chromatrographic, qualitative, and quantitative analyses of coal-derived complex mixtures; (2) chemodynamic measurements in complex organic mixtures to study the transport and transformation processes of chemicals in the environment; (3) bioassay-directed characterization of mutagenic polycyclic aromatic hydrocarbons in coal-derived materials; (4) chemical and toxicological evaluation of condensates from mild coal gasification processes; (5) development of rapid (high-pressure liquid chromatography) characterization techniques for primary aromatic amines in coal-derived liquids; (6) study of flame ionization detector response factors and chemical structure in gas chromatography; (7) development of a simple, portable device for preconcentrating airborne aromatic amines to be analyzed by portable liquid chromatography; (8) initial uptake and release studies of perchloroethylene and trichloroethylene in pine needles; (9) application of stable carbon isotope techniques in tracing environmental pollutants; (10) development of control technology for hydrazine fuels by neutralization with hypochlorite II. The Environmental Instrumentation group is engaged in research to develop and build prototype field-portable devices and instruments for the detection, identification, and quantification of volatile hazardous gases in a variety of environmental and workplace settings

  9. Screening of inorganic gases released from firework-rockets by a gas chromatography/whistle-accelerometer method.

    Science.gov (United States)

    Chen, Kuan-Fu; Wu, Hui-Hsin; Lin, Chien-Hung; Lin, Cheng-Huang

    2013-08-30

    The use of an accelerometer for detecting inorganic gases in gas chromatography (GC) is described. A milli-whistle was connected to the outlet of the GC capillary and was used instead of a classical GC detector. When the GC carrier gases and the sample gases pass through the milli-whistle, a sound is produced, leading to vibrational changes, which can be recorded using an accelerometer. Inorganic gases, including SO2, N2 and CO2, which are released from traditional Chinese firework-rockets at relatively high levels as the result of burning the propellant and explosive material inside could be rapidly determined using the GC/whistle-accelerometer system. The method described herein is safe, the instrumentation is compact and has potential to be modified so as to be portable for use in the field. It also can be used in conjunction with FID (flame ionization detector) or TCD (thermal conductivity detector), in which either no response for FID (CO2, N2, NO2, SO2, etc.) or helium gas is needed for TCD, respectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Qualitative and quantitative determination of ubiquinones by the method of high-efficiency liquid chromatography

    International Nuclear Information System (INIS)

    Yanotovskii, M.T.; Mogilevskaya, M.P.; Obol'nikova, E.A.; Kogan, L.M.; Samokhvalov, G.I.

    1986-01-01

    A method has been developed for the qualitative and quantitative determination of ubiquinones CoQ 6 -CoQ 10 , using high-efficiency reversed-phase liquid chromatography. Tocopherol acetate was used as the internal standard

  11. Simultaneous analysis for water- and fat-soluble vitamins by a novel single chromatography technique unifying supercritical fluid chromatography and liquid chromatography.

    Science.gov (United States)

    Taguchi, Kaori; Fukusaki, Eiichiro; Bamba, Takeshi

    2014-10-03

    Chromatography techniques usually use a single state in the mobile phase, such as liquid, gas, or supercritical fluid. Chromatographers manage one of these techniques for their purpose but are sometimes required to use multiple methods, or even worse, multiple techniques when the target compounds have a wide range of chemical properties. To overcome this challenge, we developed a single method covering a diverse compound range by means of a "unified" chromatography which completely bridges supercritical fluid chromatography and liquid chromatography. In our method, the phase state was continuously changed in the following order; supercritical, subcritical and liquid. Moreover, the gradient of the mobile phase starting at almost 100% CO2 was replaced with 100% methanol at the end completely. As a result, this approach achieved further extension of the polarity range of the mobile phase in a single run, and successfully enabled the simultaneous analysis of fat- and water-soluble vitamins with a wide logP range of -2.11 to 10.12. Furthermore, the 17 vitamins were exceptionally separated in 4min. Our results indicated that the use of dense CO2 and the replacement of CO2 by methanol are practical approaches in unified chromatography covering diverse compounds. Additionally, this is a first report to apply the novel approach to unified chromatography, and can open another door for diverse compound analysis in a single chromatographic technique with single injection, single column and single system. Copyright © 2014. Published by Elsevier B.V.

  12. Contribution to high-temperature chromatography and high-temperature-gas-chromatography-mass spectrometry of lipids

    International Nuclear Information System (INIS)

    Aichholz, R.

    1998-04-01

    This thesis describes the use of high temperature gas chromatography for the investigation of unusual triacylglycerols, cyanolipids and bees waxes. The used glass capillary columns were pretreated and coated with tailor made synthesized high temperature stable polysiloxane phases. The selective separation properties of the individual columns were tested with a synthetic lipid mixture. Suitable derivatization procedures for the gaschromatographic analyses of neutral lipids, containing multiple bonds as well as hydroxy-, epoxy-, and carboxyl groups, were developed and optimized. Therefore conjugated olefinic-, conjugated olefinic-acetylenic-, hydroxy-, epoxy-, and conjugated olefinic keto triacylglycerols in miscellaneous plant seed oils as well as hydroxy monoesters, diesters and hydroxy diesters in bees waxes could be analysed directly with high temperature gas chromatography for the first time. In order to elucidate the structures of separated lipid compounds, high temperature gas chromatography was coupled to mass spectrometry and tandem mass spectrometry, respectively. Comparable analytical systems are hitherto not commercial available. Therefore instrumental prerequisites for a comprehensive and detailed analysis of seed oils and bees waxes were established. In GC/MS commonly two ionization methods are used, electron impact ionization and chemical ionization. For the analysis of lipids the first is of limited use only. Due to intensive fragmentation only weak molecular ions are observed. In contrast, the chemical ionization yields in better results. Dominant quasi molecular ions enable an unambiguous determination of the molecular weight. Moreover, characteristic fragment ions provide important indications of certain structural features of the examined compounds. Nevertheless, in some cases the chromatographic resolution was insufficient in order to separate all compounds present in natural lipid mixtures. Owing to the selected detection with mass spectrometry

  13. Method Development and Validation for the Determination of Caffeine: An Alkaloid from Coffea arabica by High-performance Liquid Chromatography Method.

    Science.gov (United States)

    Naveen, P; Lingaraju, H B; Deepak, M; Medhini, B; Prasad, K Shyam

    2018-01-01

    The present study was investigated to develop and validate a reversed phase high performance liquid chromatography method for the determination of caffeine from bean material of Coffee arabica. The separation was achieved on a reversed-phase C18 column using a mobile phase composed of water: methanol (50:50) at a flow rate of 1.0 mlmin-1. The detection was carried out on a UV detector at 272 nm. The developed method was validated according to the requirements for International Conference on Harmonisation (ICH) guidelines, which includes specificity, linearity, precision, accuracy, limit of detection and limit of quantitation. The developed method validates good linearity with excellent correlation coefficient (R2 > 0.999). In repeatability and intermediate precision, the percentage relative standard deviation (% RSD) of peak area was less than 1% shows high precision of the method. The recovery rate for caffeine was within 98.78% - 101.28% indicates high accuracy of the method. The low limit of detection and limit of quantitation of caffeine enable the detection and quantitation of caffeine from C. arabica at low concentrations. The developed HPLC method is a simple, rapid, precisely, accurately and widely accepted and it is recommended for efficient assays in routine work. A simple, accurate, and sensitive high-performance liquid chromatography (HPLC) method for caffeine from Coffea arabica has been developed and validated. The developed HPLC method was validated for linearity, specificity, precision, recovery, limits of detection, and limits of quantification by the International Conference on Harmonization guidelines. The results revealed that the proposed method is highly reliable. This method could be successfully applied for routine quality work analysis. Abbreviation Used: C. arabica : Coffee arabica, ICH: International Conference on Harmonisation, % RSD: Percentage Relative Standard Deviation, R2: Correlation Coefficient, ppm: Parts per million, LOD: Limits

  14. Instrumental analysis

    International Nuclear Information System (INIS)

    Jae, Myeong Gi; Lee, Won Seong; Kim, Ha Hyeok

    1989-02-01

    This book give description of electronic engineering such as circuit element and device, circuit analysis and logic digital circuit, the method of electrochemistry like conductometry, potentiometry and current measuring, spectro chemical analysis with electromagnetic radiant rays, optical components, absorption spectroscopy, X-ray analysis, atomic absorption spectrometry and reference, chromatography like gas-chromatography and liquid-chromatography and automated analysis on control system evaluation of automated analysis and automated analysis system and reference.

  15. Instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jae, Myeong Gi; Lee, Won Seong; Kim, Ha Hyeok

    1989-02-15

    This book give description of electronic engineering such as circuit element and device, circuit analysis and logic digital circuit, the method of electrochemistry like conductometry, potentiometry and current measuring, spectro chemical analysis with electromagnetic radiant rays, optical components, absorption spectroscopy, X-ray analysis, atomic absorption spectrometry and reference, chromatography like gas-chromatography and liquid-chromatography and automated analysis on control system evaluation of automated analysis and automated analysis system and reference.

  16. Instrumental and statistical methods for the comparison of class evidence

    Science.gov (United States)

    Liszewski, Elisa Anne

    Trace evidence is a major field within forensic science. Association of trace evidence samples can be problematic due to sample heterogeneity and a lack of quantitative criteria for comparing spectra or chromatograms. The aim of this study is to evaluate different types of instrumentation for their ability to discriminate among samples of various types of trace evidence. Chemometric analysis, including techniques such as Agglomerative Hierarchical Clustering, Principal Components Analysis, and Discriminant Analysis, was employed to evaluate instrumental data. First, automotive clear coats were analyzed by using microspectrophotometry to collect UV absorption data. In total, 71 samples were analyzed with classification accuracy of 91.61%. An external validation was performed, resulting in a prediction accuracy of 81.11%. Next, fiber dyes were analyzed using UV-Visible microspectrophotometry. While several physical characteristics of cotton fiber can be identified and compared, fiber color is considered to be an excellent source of variation, and thus was examined in this study. Twelve dyes were employed, some being visually indistinguishable. Several different analyses and comparisons were done, including an inter-laboratory comparison and external validations. Lastly, common plastic samples and other polymers were analyzed using pyrolysis-gas chromatography/mass spectrometry, and their pyrolysis products were then analyzed using multivariate statistics. The classification accuracy varied dependent upon the number of classes chosen, but the plastics were grouped based on composition. The polymers were used as an external validation and misclassifications occurred with chlorinated samples all being placed into the category containing PVC.

  17. Method and apparatus for continuous fluid leak monitoring and detection in analytical instruments and instrument systems

    Science.gov (United States)

    Weitz, Karl K [Pasco, WA; Moore, Ronald J [West Richland, WA

    2010-07-13

    A method and device are disclosed that provide for detection of fluid leaks in analytical instruments and instrument systems. The leak detection device includes a collection tube, a fluid absorbing material, and a circuit that electrically couples to an indicator device. When assembled, the leak detection device detects and monitors for fluid leaks, providing a preselected response in conjunction with the indicator device when contacted by a fluid.

  18. Development and validation of ultra-high performance supercritical fluid chromatography method for determination of illegal dyes and comparison to ultra-high performance liquid chromatography method.

    Science.gov (United States)

    Khalikova, Maria A; Šatínský, Dalibor; Solich, Petr; Nováková, Lucie

    2015-05-18

    A novel simple, fast and efficient ultra-high performance supercritical fluid chromatography (UHPSFC) method was developed and validated for the separation and quantitative determination of eleven illegal dyes in chili-containing spices. The method involved a simple ultrasound-assisted liquid extraction of illegal compounds with tetrahydrofuran. The separation was performed using a supercritical fluid chromatography system and CSH Fluoro-Phenyl stationary phase at 70°C. The mobile phase was carbon dioxide and the mixture of methanol:acetonitrile (1:1, v/v) with 2.5% formic acid as an additive at the flow rate 2.0 mL min(-1). The UV-vis detection was accomplished at 500 nm for seven compounds and at 420 nm for Sudan Orange G, Butter Yellow, Fast Garnet GBC and Methyl Red due to their maximum of absorbance. All eleven compounds were separated in less than 5 min. The method was successfully validated and applied using three commercial samples of chili-containing spices - Chili sauce (Indonesia), Feferony sauce (Slovakia) and Mojo sauce (Spain). The linearity range of proposed method was 0.50-9.09 mg kg(-1) (r ≥ 0.995). The detection limits were determined as signal to noise ratio of 3 and were ranged from 0.15 mg kg(-1) to 0.60 mg kg(-1) (1.80 mg kg(-1) for Fast Garnet) for standard solution and from 0.25 mg kg(-1) to 1.00 mg kg(-1) (2.50 mg kg(-1) for Fast Garnet, 1.50 mg kg(-1) for Sudan Red 7B) for chili-containing samples. The recovery values were in the range of 73.5-107.2% and relative standard deviation ranging from 0.1% to 8.2% for within-day precision and from 0.5% to 8.8% for between-day precision. The method showed potential for being used to monitor forbidden dyes in food constituents. The developed UHPSFC method was compared to the UHPLC-UV method. The orthogonality of Sudan dyes separation by these two methods was demonstrated. Benefits and drawbacks were discussed showing the reliability of both methods for monitoring of studied illegal dyes in real

  19. Supercritical fluid chromatography

    Science.gov (United States)

    Vigdergauz, M. S.; Lobachev, A. L.; Lobacheva, I. V.; Platonov, I. A.

    1992-03-01

    The characteristic features of supercritical fluid chromatography (SCFC) are examined and there is a brief historical note concerning the development of the method. Information concerning the use of supercritical fluid chromatography in the analysis of objects of different nature is presented in the form of a table. The roles of the mobile and stationary phases in the separation process and the characteristic features of the apparatus and of the use of the method in physicochemical research are discussed. The bibliography includes 364 references.

  20. Application of an online ion-chromatography-based instrument for gradient flux measurements of speciated nitrogen and sulfur

    Science.gov (United States)

    Rumsey, Ian C.; Walker, John T.

    2016-06-01

    The dry component of total nitrogen and sulfur atmospheric deposition remains uncertain. The lack of measurements of sufficient chemical speciation and temporal extent make it difficult to develop accurate mass budgets and sufficient process level detail is not available to improve current air-surface exchange models. Over the past decade, significant advances have been made in the development of continuous air sampling measurement techniques, resulting with instruments of sufficient sensitivity and temporal resolution to directly quantify air-surface exchange of nitrogen and sulfur compounds. However, their applicability is generally restricted to only one or a few of the compounds within the deposition budget. Here, the performance of the Monitor for AeRosols and GAses in ambient air (MARGA 2S), a commercially available online ion-chromatography-based analyzer is characterized for the first time as applied for air-surface exchange measurements of HNO3, NH3, NH4+, NO3-, SO2 and SO42-. Analytical accuracy and precision are assessed under field conditions. Chemical concentrations gradient precision are determined at the same sampling site. Flux uncertainty measured by the aerodynamic gradient method is determined for a representative 3-week period in fall 2012 over a grass field. Analytical precision and chemical concentration gradient precision were found to compare favorably in comparison to previous studies. During the 3-week period, percentages of hourly chemical concentration gradients greater than the corresponding chemical concentration gradient detection limit were 86, 42, 82, 73, 74 and 69 % for NH3, NH4+, HNO3, NO3-, SO2 and SO42-, respectively. As expected, percentages were lowest for aerosol species, owing to their relatively low deposition velocities and correspondingly smaller gradients relative to gas phase species. Relative hourly median flux uncertainties were 31, 121, 42, 43, 67 and 56 % for NH3, NH4+, HNO3, NO3-, SO2 and SO42-, respectively. Flux

  1. Supercritical Fluid Chromatography--Theoretical Background and Applications on Natural Products.

    Science.gov (United States)

    Hartmann, Anja; Ganzera, Markus

    2015-11-01

    The use of supercritical fluid chromatography for natural product analysis as well as underlying theoretical mechanisms and instrumental requirements are summarized in this review. A short introduction focusing on the historical development of this interesting separation technique is followed by remarks on the current instrumental design, also describing possible detection modes and useable stationary phases. The overview on relevant applications is grouped based on their basic intention, may it be (semi)preparative or purely analytical. They indicate that supercritical fluid chromatography is still primarily considered for the analysis of nonpolar analytes like carotenoids, fatty acids, or terpenes. The low polarity of supercritical carbon dioxide, which is used with modifiers almost exclusively as a mobile phase today, combined with high efficiency and fast separations might explain the popularity of supercritical fluid chromatography for the analysis of these compounds. Yet, it has been shown that more polar natural products (e.g., xanthones, flavonoids, alkaloids) are separable too, with the same (if not superior) selectivity and reproducibility than established approaches like HPLC or GC. Georg Thieme Verlag KG Stuttgart · New York.

  2. Falsification Testing of Instrumental Variables Methods for Comparative Effectiveness Research.

    Science.gov (United States)

    Pizer, Steven D

    2016-04-01

    To demonstrate how falsification tests can be used to evaluate instrumental variables methods applicable to a wide variety of comparative effectiveness research questions. Brief conceptual review of instrumental variables and falsification testing principles and techniques accompanied by an empirical application. Sample STATA code related to the empirical application is provided in the Appendix. Comparative long-term risks of sulfonylureas and thiazolidinediones for management of type 2 diabetes. Outcomes include mortality and hospitalization for an ambulatory care-sensitive condition. Prescribing pattern variations are used as instrumental variables. Falsification testing is an easily computed and powerful way to evaluate the validity of the key assumption underlying instrumental variables analysis. If falsification tests are used, instrumental variables techniques can help answer a multitude of important clinical questions. © Health Research and Educational Trust.

  3. State-of-the art of selective detection and identification of I-, Br-, Cl-, and F-containing compounds in gas chromatography and liquid chromatography.

    Science.gov (United States)

    Brede, Cato; Pedersen-Bjergaard, Stig

    2004-09-24

    This review article presents an overview of halogen-specific detection in gas chromatography (GC) and liquid chromatography (LC). Attention is primarily focused on the use of plasma emission spectroscopy and plasma mass spectrometry as detectors, but other halogen-selective detection principles are also mentioned. Different instrumental configurations are discussed both with respect to technical set-up and performance, the principal reasons for halogen-selective detection are highlighted, and recent applications are reviewed from areas such as environmental chemistry, petroleum characterization, and drug analysis.

  4. Instrumentation and quantitative methods of evaluation

    International Nuclear Information System (INIS)

    Beck, R.N.; Cooper, M.D.

    1991-01-01

    This report summarizes goals and accomplishments of the research program entitled Instrumentation and Quantitative Methods of Evaluation, during the period January 15, 1989 through July 15, 1991. This program is very closely integrated with the radiopharmaceutical program entitled Quantitative Studies in Radiopharmaceutical Science. Together, they constitute the PROGRAM OF NUCLEAR MEDICINE AND QUANTITATIVE IMAGING RESEARCH within The Franklin McLean Memorial Research Institute (FMI). The program addresses problems involving the basic science and technology that underlie the physical and conceptual tools of radiotracer methodology as they relate to the measurement of structural and functional parameters of physiologic importance in health and disease. The principal tool is quantitative radionuclide imaging. The objective of this program is to further the development and transfer of radiotracer methodology from basic theory to routine clinical practice. The focus of the research is on the development of new instruments and radiopharmaceuticals, and the evaluation of these through the phase of clinical feasibility. 234 refs., 11 figs., 2 tabs

  5. Chromatography of phosphorus oxoacids

    International Nuclear Information System (INIS)

    Ohashi, S.

    1975-01-01

    The present state of studies on the chromatographic separation of phosphorus oxoacids is surveyed. In this paper, chromatographic techniques are divided into four groups, i.e. paper and thin-layer chromatography, paper electrophoresis, ion-exchange chromatography, and gel chromatography. The separation mechanisms and characteristics for these chromatographic methods are discussed and some examples for the separation of phosphorus oxoacids are described. As examples of the application of ion-exchange and gel chromatography, studies on the hot atom chemistry of 32 P in solid inorganic phosphates and those on the substitution reactions between diphosphonate (diphosphite) and polyphosphates are reported. (author)

  6. Counter-current motion in counter-current chromatography.

    Science.gov (United States)

    Ito, Yoichiro

    2014-12-12

    After the CCC2012 meeting, I have received an e-mail regarding the terminology of "Countercurrent Chromatography". It stated that the term "Countercurrent" is a misnomer, because its stationary phase is motionless in the column and that the method should be renamed as liquid-liquid separations or centrifugal separations. However, it was found that these names are already used for various other techniques as found via Google search. The term "Countercurrent Chromatography" was originally made after two preparative methods of Countercurrent distribution and liquid Chromatography, both having no countercurrent motion in the column. However, it is surprising to find that this F1 hybrid method "Countercurrent Chromatography" can clearly exhibit countercurrent motion within the separation column in both hydrodynamic and hydrostatic equilibrium systems. This justifies that "Countercurrent Chromatography" is a proper term for this chromatographic method. Published by Elsevier B.V.

  7. Determination of phthalate diesters and monoesters in human milk and infant formula by fat extraction, size-exclusion chromatography clean-up and gas chromatography-mass spectrometry detection.

    Science.gov (United States)

    Del Bubba, Massimo; Ancillotti, Claudia; Checchini, Leonardo; Fibbi, Donatella; Rossini, Daniele; Ciofi, Lorenzo; Rivoira, Luca; Profeti, Claudio; Orlandini, Serena; Furlanetto, Sandra

    2018-01-30

    A sensitive and reliable analytical method was developed for the simultaneous determination of five phthalate diesters and corresponding monoesters in human milk samples and infant formulas. The method involved a liquid-liquid extraction with a CH 2 Cl 2 /CH 3 OH/NaCl 30% 2/1/0.5 (v/v/v) mixture, the clean-up of the extract by size-exclusion chromatography (swelling and elution solvent: cyclohexane/ethyl acetate 9/1v/v), the derivatization of monoesters by trimethylsilyl-diazomethane and instrumental analysis by gas chromatography coupled with mass spectrometry. Recovery was in the range of 83-115% and precision was found between 9% and 21%. For phthalate diesters, method detection limits (MDLs) ranged from hundreds of ng/kg to 4.2μg/kg on a fresh weight milk (f.w.) basis, depending on blank contribution evaluated in matrix. Lower MDLs (0.03-0.8μg/kg f.w.) were achieved for corresponding monoesters. The proposed method was applied to the determination of target compounds in nine human milk samples and four infant formulas, confirming their presence in all samples. However, a generally higher contamination was assessed in artificial milk than in breast milk samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Instrumental variable methods in comparative safety and effectiveness research.

    Science.gov (United States)

    Brookhart, M Alan; Rassen, Jeremy A; Schneeweiss, Sebastian

    2010-06-01

    Instrumental variable (IV) methods have been proposed as a potential approach to the common problem of uncontrolled confounding in comparative studies of medical interventions, but IV methods are unfamiliar to many researchers. The goal of this article is to provide a non-technical, practical introduction to IV methods for comparative safety and effectiveness research. We outline the principles and basic assumptions necessary for valid IV estimation, discuss how to interpret the results of an IV study, provide a review of instruments that have been used in comparative effectiveness research, and suggest some minimal reporting standards for an IV analysis. Finally, we offer our perspective of the role of IV estimation vis-à-vis more traditional approaches based on statistical modeling of the exposure or outcome. We anticipate that IV methods will be often underpowered for drug safety studies of very rare outcomes, but may be potentially useful in studies of intended effects where uncontrolled confounding may be substantial.

  9. Instrumental variable methods in comparative safety and effectiveness research†

    Science.gov (United States)

    Brookhart, M. Alan; Rassen, Jeremy A.; Schneeweiss, Sebastian

    2010-01-01

    Summary Instrumental variable (IV) methods have been proposed as a potential approach to the common problem of uncontrolled confounding in comparative studies of medical interventions, but IV methods are unfamiliar to many researchers. The goal of this article is to provide a non-technical, practical introduction to IV methods for comparative safety and effectiveness research. We outline the principles and basic assumptions necessary for valid IV estimation, discuss how to interpret the results of an IV study, provide a review of instruments that have been used in comparative effectiveness research, and suggest some minimal reporting standards for an IV analysis. Finally, we offer our perspective of the role of IV estimation vis-à-vis more traditional approaches based on statistical modeling of the exposure or outcome. We anticipate that IV methods will be often underpowered for drug safety studies of very rare outcomes, but may be potentially useful in studies of intended effects where uncontrolled confounding may be substantial. PMID:20354968

  10. Optimization of the combination micro-high-performance liquid-chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Haider, K.

    1997-03-01

    The coupling of liquid chromatography and mass spectrometry is still growing in significance. In this thesis, a particle beam interface has been investigated for combining ion chromatography with mass spectrometric detection. To introduce the eluent directly (without membrane suppressor) into the spectrometer, only methods with low flow rates like microcolumn chromatography can be used. For the preparation of the columns, reversed-phase and silica-based anion exchange materials were packed into PEEK, steel and fused-silica capillaries with i.d. from 130 to 1000 μm using different methods. The performance of the particle beam interface (modified with a new miniaturized aerosol generator) and the mass spectrometric detection has been studied for a series of inorganic anions as well as aminopolycarboxylic acids and the metal-EDTA complexes. Detection limits between 10 and 100 ng injected could be achieved in the multiple ion detection mode of the mass spectrometer for the investigated solutes. A second type of interface, the direct liquid introduction (DLI) has been used to analyze the priority pollutant phenols. This interface is based on a modified GC-interface into the MS. Separation columns used so far include packed fused-silica capillaries with inner diameter of 75 μm and polystyrene-divinylbenzene (functionalized with tert. butyl groups) as stationary phase. Aspects of instrumentation and effects of chemical ionization in the direct liquid introduction mode are discussed. (author)

  11. A multi-criteria evaluation method for climate change mitigation policy instruments

    International Nuclear Information System (INIS)

    Konidari, Popi; Mavrakis, Dimitrios

    2007-01-01

    This paper presents an integrated multi-criteria analysis method for the quantitative evaluation of climate change mitigation policy instruments. The method consists of: (i) a set of criteria supported by sub-criteria, all of which describe the complex framework under which these instruments are selected by policy makers and implemented, (ii) an Analytical Hierarchy Process (AHP) process for defining weight coefficients for criteria and sub-criteria according to the preferences of three stakeholders groups and (iii) a Multi-Attribute Theory (MAUT)/Simple Multi-Attribute Ranking Technique (SMART) process for assigning grades to each instrument that is evaluated for its performance under a specific sub-criterion. Arguments for the selected combination of these standard methods and definitions for criteria/sub-criteria are quoted. Consistency and robustness tests are performed. The functionality of the proposed method is tested by assessing the aggregate performances of the EU emission trading scheme at Denmark, Germany, Greece, Italy, Netherlands, Portugal, Sweden and United Kingdom. Conclusions are discussed

  12. Q Sepharose micro-column chromatography: A simple screening method for identifying beta thalassemia traits and hemoglobin E carriers.

    Science.gov (United States)

    Wong, Peerapon; Sritippayawan, Suchila; Suwannakhon, Narutchala; Tapprom, Akamon; Deoisares, Rawisut; Sanguansermsri, Torpong

    2016-11-01

    For beta thalassemia control program in pregnancy, mass screening of the carrier state by determination of the hemoglobin (Hb) A 2 and Hb E proportions and mutation analysis is a preferred method for making prenatal diagnoses. Q Sepharose micro-column chromatography, developed for the determination of Hb A 2 and Hb E for screening purposes, was compared with high performance liquid chromatography (HPLC) to ascertain its relative accuracy and reliability. Results using Q Sepharose micro-column chromatography in 350 blood specimens, including 50 samples genetically proven to be beta thalassemia heterozygotes, were compared to HPLC for validation. An additional study was conducted to test a clinical application on a large-scale survey for beta thalassemia in 1581 pregnant women and their spouses. The mean (±SD) Hb A 2 proportions in the normal and genetically proven beta thalassemia heterozygotes were 2.70±0.40% and 6.30±1.23%, respectively, as determined by Q-Sepharose micro-column chromatography, and 2.65±0.31% and 5.37±0.96%, respectively, as determined by HPLC. The mean Hb E proportions in the Hb E heterozygotes were 23.25±4.13% and 24.72±3.5% as determined by Q Sepharose micro-column chromatography and HPLC, respectively. In the large-scale survey for beta thalassemia, 23 at risk couples were detected. Seven affected fetuses were identified by prenatal diagnosis. Q Sepharose micro-column chromatography was found to be reliable, reproducible and well-suited for large-scale surveys. Additionally, by being reusable and convenient, this simple and economical chromatography method may be an alternative means to screen for beta thalassemia and Hb E carriers in the mass population. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Instrumentation and measurement method for the ATLAS test facility

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Byong Jo; Chu, In Chul; Eu, Dong Jin; Kang, Kyong Ho; Kim, Yeon Sik; Song, Chul Hwa; Baek, Won Pil

    2007-03-15

    An integral effect test loop for pressurized water reactors (PWRs), the ATLAS is constructed by thermal-hydraulic safety research division in KAERI. The ATLAS facility has been designed to have the length scale of 1/2 and area scale of 1/144 compared with the reference plant, APR1400 which is a Korean evolution type nuclear reactors. A total 1300 instrumentations is equipped in the ATLAS test facility. In this report, the instrumentation of ATLAS test facility and related measurement methods were introduced.

  14. Instrument for Solvent Extraction and Analysis (ISEE) of Organics from Regolith Simulant Using Supercritical Fluid Extraction and Chromatography

    Science.gov (United States)

    Franco, Carolina; Hintze, Paul E.

    2017-01-01

    ISEE is an instrument with the potential to perform extractions from regolith found on the surface of asteroids and planets, followed by characterization and quantitation of the extracts using supercritical fluid extraction (SFE) and chromatography (SFC). SFE is a developed technique proven to extract a wide range of organic compounds. SFC is similar to High Performance Liquid Chromatography (HPLC) but has the advantage of performing chiral separations without needing to derivatize the chiral compounds. CO2 will be the solvent for both stages as it is readily available in the Mars atmosphere. ISEE will capture CO2 from the environment, and use it for SFE and SFC. If successful, this would allow ISEE to perform analysis of organic compounds without using consumables. This paper will present results on a preliminary, proof-of-principle effort to use SFE and SFC to extract and analyze lunar regolith simulant spiked with organic compounds representing a range of organics that ISEE would expect to characterize. An optimization of variables for the extraction of the organics from the spiked regolith was successfully developed, using 138 bar pressure and 40 C temperature. The extraction flow rate was optimized at 2% SLPM with 30% methanol modifier. The extractions were successful with a value of 77.3+/- 0.9% of organics extracted. However, the recovery of organics after the extraction was very low with only 48.5+/-14.2%. Moreover, three columns were selected to analyze multiple samples at a time; two of them are Viridis HSS C18 SB and Torus DIOL, and the third column, specific for chiral separations, has not yet been selected yet.

  15. Main Achievements 2003-2004 - Interdisciplinary Research - Radiation detection methods for health, earth and environmental sciences - Detection methods in gas chromatography

    International Nuclear Information System (INIS)

    2005-01-01

    Detection methods in gas chromatography are under development, especially ultra-sensitive gas chromatography detection methods to monitor the atmosphere (with respect to gases active in the destruction of the Earth ozone layer). A new chromatographic method has been elaborated for Ne determination, and technique for determination of Ar and N 2 in groundwater has been significantly improved. Measurements of neon are performed by means of a chromatographic system equipped with a helium ionization detector (PD-HID) doped with neon pulse discharge, working with a modified sample introduction system. The Ar and N 2 contents are determined by a thermal-conductivity detector (TCD). The problem of separation of Ar from O 2 has been solved by catalytic removal of the latter from the sample. The measurement reproducibility is 1%, 2% and 0.5% for Ar, Ne and N 2 , respectively. Both methods were successfully applied in measurements of groundwaters in the Cracow area. The excess air contents are in the range of about 1 to 3 cm 3 STP L-1. The values of recharge temperatures for Holocen water agree reasonably well with the yearly mean long-term surface air temperature (8.2 o C)

  16. Fast methods for screening of trichothecenes in fungal cultures using gas chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Kristian Fog; Thrane, Ulf

    2001-01-01

    The paper presents a fast method for trichothecene profiling and chemotaxonomic studies in species of Fusarium, Stachybotrys, Trichoderma and Memnoniella. Micro scale extracted crude Fusarium extracts were derivatised using pentafluoropropionic anhydride and analysed by gas chromatography...

  17. Two-step Purification Method for Aging Pigments A2E and Iso-A2E Using Medium Pressure Liquid Chromatography

    International Nuclear Information System (INIS)

    Park, Sang Il; Park, Sang Cheol; Kim, So Ra; Jang, Young Pyo

    2016-01-01

    A newly modified method for the efficient purification of A2E and iso-A2E using reverse phase silica gel resin with medium pressure liquid chromatography (MPLC) was suggested. MPLC is one of the various preparative column chromatography techniques and separation under pressure renders the use of smaller particle size resins possible and increases the diversity of available stationary phases. A simplified two-step purification method was developed for the purification of aging pigments in eye, A2E and iso-A2E. With simple two-step elution of mobile phase in reverse phase MPLC, A2E and iso-A2E were successfully purified with great efficiency compare with previous column chromatography and HPLC method. This method provides more simple, convenient, cost-effective, and less time-consuming procedure for mass purification of aging pigments A2E and iso-A2E

  18. Two-step Purification Method for Aging Pigments A2E and Iso-A2E Using Medium Pressure Liquid Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Il; Park, Sang Cheol [Kyunghee Univ., Seoul (Korea, Republic of); Kim, So Ra; Jang, Young Pyo [Seoul National Univ., Seoul (Korea, Republic of)

    2016-09-15

    A newly modified method for the efficient purification of A2E and iso-A2E using reverse phase silica gel resin with medium pressure liquid chromatography (MPLC) was suggested. MPLC is one of the various preparative column chromatography techniques and separation under pressure renders the use of smaller particle size resins possible and increases the diversity of available stationary phases. A simplified two-step purification method was developed for the purification of aging pigments in eye, A2E and iso-A2E. With simple two-step elution of mobile phase in reverse phase MPLC, A2E and iso-A2E were successfully purified with great efficiency compare with previous column chromatography and HPLC method. This method provides more simple, convenient, cost-effective, and less time-consuming procedure for mass purification of aging pigments A2E and iso-A2E.

  19. High Performance Liquid Chromatography of Some Analgesic Compounds: An Instrumental Analysis Experiment.

    Science.gov (United States)

    Haddad, Paul; And Others

    1983-01-01

    Background information, procedures, and results are provided for an experiment demonstrating techniques of solvent selection, gradient elution, pH control, and ion-pairing in the analysis of an analgesic mixture using reversed-phase liquid chromatography on an octadecylsilane column. Although developed using sophisticated/expensive equipment, less…

  20. A Mixed Methods Portrait of Urban Instrumental Music Teaching

    Science.gov (United States)

    Fitzpatrick, Kate R.

    2011-01-01

    The purpose of this mixed methods study was to learn about the ways that instrumental music teachers in Chicago navigated the urban landscape. The design of the study most closely resembles Creswell and Plano Clark's (2007) two-part Triangulation Convergence Mixed Methods Design, with the addition of an initial exploratory focus group component.…

  1. Development of the H-point standard additions method for coupled liquid-chromatography and UV-visible spectrophotometry

    Energy Technology Data Exchange (ETDEWEB)

    Campins-Falco, Pilar; Bosch-Reig, Francisco; Herraez-Hernandez, Rosa; Sevillano-Cabeza, Adela (Universidad de Valencia (Spain). Facultad de Quimica, Departamento de Quimica Analitica)

    1992-02-10

    This work establishes the fundamentals of the H-point standard additions method for liquid chromatography for the simultaneous analysis of binary mixtures with overlapped chromatographic peaks. The method was compared with the deconvolution method of peak suppression and the second derivative of elution profiles. Different mixtures of diuretics were satisfactorily resolved. (author). 21 refs.; 9 figs.; 2 tabs.

  2. Design and implementation of an array of micro-electrochemical detectors for two-dimensional liquid chromatography--proof of principle.

    Science.gov (United States)

    Abia, Jude A; Putnam, Joel; Mriziq, Khaled; Guiochon, Georges A

    2010-03-05

    Simultaneous two-dimensional liquid chromatography (2D-LC) is an implementation of two-dimensional liquid chromatography which has the potential to provide very fast, yet highly efficient separations. It is based on the use of time x space and space x space separation systems. The basic principle of this instrument has been validated long ago by the success of two-dimensional thin layer chromatography. The construction of a pressurized wide and flat column (100 mm x 100 mm x 1 mm) operated under an inlet pressure of up to 50 bar was described previously. However, to become a modern analytical method, simultaneous 2D-LC requires the development of detectors suitable for the monitoring of the composition of the eluent of this pressurized planar, wide column. An array of five equidistant micro-electrochemical sensors was built for this purpose and tested. Each sensor is a three-electrode system, with the working electrode being a 25 microm polished platinum micro-electrode. The auxiliary electrode is a thin platinum wire and the reference electrode an Ag/AgCl (3M sat. KCl) electrode. In this first implementation, proof of principle is demonstrated, but the final instrument will require a much larger array. 2010 Elsevier B.V. All rights reserved.

  3. Preparation and Characterization of a Polymeric Monolithic Column for Use in High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Bindis, Michael P.; Bretz, Stacey Lowery; Danielson, Neil D.

    2011-01-01

    The high-performance liquid chromatography (HPLC) experiment, most often done in the undergraduate analytical instrumentation laboratory course, generally illustrates reversed-phase chromatography using a commercial C[subscript]18 silica column. To avoid the expense of periodic column replacement and introduce a choice of columns with different…

  4. Integration of gas chromatography mass spectrometry methods for differentiating ricin preparation methods.

    Science.gov (United States)

    Wunschel, David S; Melville, Angela M; Ehrhardt, Christopher J; Colburn, Heather A; Victry, Kristin D; Antolick, Kathryn C; Wahl, Jon H; Wahl, Karen L

    2012-05-07

    The investigation of crimes involving chemical or biological agents is infrequent, but presents unique analytical challenges. The protein toxin ricin is encountered more frequently than other agents and is found in the seeds of Ricinus communis, commonly known as the castor plant. Typically, the toxin is extracted from castor seeds utilizing a variety of different recipes that result in varying purity of the toxin. Moreover, these various purification steps can also leave or differentially remove a variety of exogenous and endogenous residual components with the toxin that may indicate the type and number of purification steps involved. We have applied three gas chromatography-mass spectrometry (GC-MS) based analytical methods to measure the variation in seed carbohydrates and castor oil ricinoleic acid, as well as the presence of solvents used for purification. These methods were applied to the same samples prepared using four previously identified toxin preparation methods, starting from four varieties of castor seeds. The individual data sets for seed carbohydrate profiles, ricinoleic acid, or acetone amount each provided information capable of differentiating different types of toxin preparations across seed types. However, the integration of the data sets using multivariate factor analysis provided a clear distinction of all samples based on the preparation method, independent of the seed source. In particular, the abundance of mannose, arabinose, fucose, ricinoleic acid, and acetone were shown to be important differentiating factors. These complementary tools provide a more confident determination of the method of toxin preparation than would be possible using a single analytical method.

  5. DETERMINATION OF RUTIN IN LEAVES OF SALIX TRIANDRA USING THE METHOD OF PLANAR CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    E. G. Sannikova

    2016-01-01

    Full Text Available The aim of the study is to develop new methods of identification and quantitative determination of rutin in the leaves of Salix triandra L. with thin-layer chromatography. The digital processing of the chromatograms was performed using «Sorbfil Videodensitometer» computer program (Krasnodar. For the chromatography analysis we used plates «Sorbfil» PTSH-P-A-UV, mobile phase: n-butanol-glacial acetic acid-water (4:1:1, detecting reagent – ammonia vapors. The rutin is detected as yellow spots with Rf 0.64±0.02. The detection limit is 0.5 μg/μl. The regression equation has the form: S=4.75×103 m. With the use of this method we found that the composition of rutin in leaves of Salix triandra was in the range 1.81±0.06% on the air-dry raw material (relative standard deviation RSD%=2.5%; the measurement error E=3.12%. The method is sensitive, linear, has a small error, and does not require expensive equipment.

  6. XII All-Russian conference on gas chromatography. Program. Summary of reports

    International Nuclear Information System (INIS)

    2002-01-01

    Program and summary of reports of the XII All-Russian conference on gas chromatography are performed. The conference took place in Samara, 10-14 June, 2002. Reports on physicochemical regularities of gas chromatography, application of chromatographic methods in atomic energetics are included in the program of the conference. Part of the reports are deleted to the analytical application of the gas chromatography. Adsorbents for the gas chromatography, complex methods, mathematic methods in chromatography, ecological aspects of the gas chromatography [ru

  7. Chromatography.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  8. Simultaneous determination of seven flavonoids in Epimedium by liquid chromatography-tandem mass spectrometry method

    Institute of Scientific and Technical Information of China (English)

    Cai Sheng Wu; Bao Lin Guo; Yu Xin Sheng; Jin Lan Zhang

    2008-01-01

    In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoids, namely epimedin A, epimedin B, epimedin C, icariin, sagittatoside B, 2"-0-rhamnosyl icariside II, and baohuoside I in Epimedium from different sources.

  9. Evolution in miniaturized column liquid chromatography instrumentation and applications: An overview.

    Science.gov (United States)

    Nazario, Carlos E D; Silva, Meire R; Franco, Maraíssa S; Lanças, Fernando M

    2015-11-20

    The purpose of this article is to underline the miniaturized LC instrumental system and describe the evolution of commercially available systems by discussing their advantages and drawbacks. Nowadays, there are already many miniaturized LC systems available with a great variety of pump design, interface and detectors as well as efficient columns technologies and reduced connections devices. The solvent delivery systems are able to drive the mobile phase without flow splitters and promote gradient elution using either dual piston reciprocating or syringe-type pumps. The mass spectrometry as detection system is the most widely used detection system; among many alternative ionization sources direct-EI LC-MS is a promising alternative to APCI. In addition, capillary columns are now available showing many possibilities of stationary phases, inner diameters and hardware materials. This review provides a discussion about miniaturized LC demonstrating fundamentals and instrumentals' aspects of the commercially available miniaturized LC instrumental system mainly nano and micro LC formats. This review also covers the recent developments and trends in instrumentation, capillary and nano columns, and several applications of this very important and promising field. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Performance evaluation methods and instrumentation for mine ventilation fans

    Institute of Scientific and Technical Information of China (English)

    LI Man; WANG Xue-rong

    2009-01-01

    Ventilation fans are one of the most important pieces of equipment in coal mines. Their performance plays an important role in the safety of staff and production. Given the actual requirements of coal mine production, we instituted a research project on the measurement methods of key performance parameters such as wind pressure, amount of ventilation and power. At the end a virtual instrument for mine ventilation fans performance evaluation was developed using a USB interface. The practical perform-ance and analytical results of our experiments show that it is feasible, reliable and effective to use the proposed instrumentation for mine ventilation performance evaluation.

  11. Downstream processing and chromatography based analytical methods for production of vaccines, gene therapy vectors, and bacteriophages

    Science.gov (United States)

    Kramberger, Petra; Urbas, Lidija; Štrancar, Aleš

    2015-01-01

    Downstream processing of nanoplexes (viruses, virus-like particles, bacteriophages) is characterized by complexity of the starting material, number of purification methods to choose from, regulations that are setting the frame for the final product and analytical methods for upstream and downstream monitoring. This review gives an overview on the nanoplex downstream challenges and chromatography based analytical methods for efficient monitoring of the nanoplex production. PMID:25751122

  12. Purification of lignans from Fructus Arctii using off-line two-dimensional supercritical fluid chromatography/reversed-phase liquid chromatography.

    Science.gov (United States)

    Yang, Bichao; Xin, Huaxia; Wang, Feier; Cai, Jianfeng; Liu, Yanfang; Fu, Qing; Jin, Yu; Liang, Xinmiao

    2017-08-01

    As a common traditional Chinese medicine, Fructus Arctii has important clinical medical values. Its main components are lignans, which are difficult to separate and analyze because of the complex composition, similar chemical structures, and close properties. In this study, an off-line two-dimensional supercritical fluid chromatography/reversed-phase liquid chromatography method, as well as an effective sample pretreatment method based on hydrophilic interaction chromatography material, was developed to enrich the minor lignan fractions and obtain high-purity compounds. In total, 12 high-purity compounds were isolated from Fructus Arctii. Their structures were identified by using high-resolution mass spectrometry and nuclear magnetic resonance spectroscopy, which showed that all were lignans and that most of them were isomers. The results demonstrated the effective off-line two-dimensional supercritical fluid chromatography/reversed-phase liquid chromatography method for the purification of lignans from Fructus Arctii. The separation protocol established here will be beneficial for the separation of complex samples from other kinds of natural products. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Fuel spill identification by gas chromatography -- genetic algorithms/pattern recognition techniques

    International Nuclear Information System (INIS)

    Lavine, B.K.; Moores, A.J.; Faruque, A.

    1998-01-01

    Gas chromatography and pattern recognition methods were used to develop a potential method for typing jet fuels so a spill sample in the environment can be traced to its source. The test data consisted of 256 gas chromatograms of neat jet fuels. 31 fuels that have undergone weathering in a subsurface environment were correctly identified by type using discriminants developed from the gas chromatograms of the neat jet fuels. Coalescing poorly resolved peaks, which occurred during preprocessing, diminished the resolution and hence information content of the GC profiles. Nevertheless a genetic algorithm was able to extract enough information from these profiles to correctly classify the chromatograms of weathered fuels. This suggests that cheaper and simpler GC instruments ca be used to type jet fuels

  14. Collaborative trial validation study of two methods, one based on high performance liquid chromatography-tandem mass spectrometry and on gas chromatography-mass spectrometry for the determination of acrylamide in bakery and potato products.

    Science.gov (United States)

    Wenzl, Thomas; Karasek, Lubomir; Rosen, Johan; Hellenaes, Karl-Erik; Crews, Colin; Castle, Laurence; Anklam, Elke

    2006-11-03

    A European inter-laboratory study was conducted to validate two analytical procedures for the determination of acrylamide in bakery ware (crispbreads, biscuits) and potato products (chips), within a concentration range from about 20 microg/kg to about 9000 microgg/kg. The methods are based on gas chromatography-mass spectrometry (GC-MS) of the derivatised analyte and on high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) of native acrylamide. Isotope dilution with isotopically labelled acrylamide was an integral part of both methods. The study was evaluated according to internationally accepted guidelines. The performance of the HPLC-MS/MS method was found to be superior to that of the GC-MS method and to be fit-for-the-purpose.

  15. Extraction chromatography of fission products

    International Nuclear Information System (INIS)

    Bonnevie-Svendsen, M.; Goon, K.

    1978-01-01

    Various cases of using extraction chromatography during analysis of fission products are reviewed. The use of the extraction chromatography method is considered while analysing reprocessed products of nuclear fuel for quantitative radiochemical analysis and control of fission product and actinoide separation during extraction and their chemical state in production solutions. The method is used to obtain pure fractions of typical burnup monitors (neodymium, molybdenum, cerium, cesium, europium, lanthanides) during determination of nuclear fuel burnup degree. While studying the nature of nuclear reactions the method is used to separate quickly short-life isotopes, to purify β-radiator fractions before measuring their half-life periods, to enrich isotopes forming with low output during fission. Examples of using extraction chromatography are given to separate long half-life or stable fission products from spent solutions, to control environment object contamination

  16. Chromium Speciation Analysis by Ion Chromatography Coupled ...

    African Journals Online (AJOL)

    Two methods coupling ion chromatography with inductively coupled plasma - optical emission spectroscopy (ICP-OES) were developed for the simultaneous separation and determination of Cr(III) and Cr(VI) species. In the first method, anion chromatography with sodium bicarbonate/carbonate solution as the eluent was ...

  17. Chemistry and liquid chromatography methods for the analyses of primary oxidation products of triacylglycerols.

    Science.gov (United States)

    Zeb, A

    2015-05-01

    Triacylglycerols (TAGs) are one of the major components of the cells in higher biological systems, which can act as an energy reservoir in the living cells. The unsaturated fatty acid moiety is the key site of oxidation and formation of oxidation compounds. The TAG free radical generates several primary oxidation compounds. These include hydroperoxides, hydroxides, epidioxides, hydroperoxy epidioxides, hydroxyl epidioxides, and epoxides. The presence of these oxidized TAGs in the cell increases the chances of several detrimental processes. For this purpose, several liquid chromatography (LC) methods were reported in their analyses. This review is therefore focused on the chemistry, oxidation, extraction, and the LC methods reported in the analyses of oxidized TAGs. The studies on thin-layer chromatography were mostly focused on the total oxidized TAGs separation and employ hexane as major solvent. High-performance LC (HPLC) methods were discussed in details along with their merits and demerits. It was found that most of the HPLC methods employed isocratic elution with methanol and acetonitrile as major solvents with an ultraviolet detector. The coupling of HPLC with mass spectrometry (MS) highly increases the efficiency of analysis as well as enables reliable structural elucidation. The use of MS was found to be helpful in studying the oxidation chemistry of TAGs and needs to be extended to the complex biological systems.

  18. On-line comprehensive two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography for preparative isolation of Peucedanum praeruptorum.

    Science.gov (United States)

    Wang, Xin-Yuan; Li, Jia-Fu; Jian, Ya-Mei; Wu, Zhen; Fang, Mei-Juan; Qiu, Ying-Kun

    2015-03-27

    A new on-line comprehensive preparative two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was developed for the separation of complicated natural products. It was based on the use of a silica gel packed medium-pressure column as the first dimension and an ODS preparative HPLC column as the second dimension. The two dimensions were connected with normal-phase (NP) and reversed-phase (RP) enrichment units, involving a newly developed airflow assisted adsorption (AAA) technique. The instrument operation and the performance of this NPLC × RPLC separation method were illustrated by gram-scale isolation of ethanol extract from the roots of Peucedanum praeruptorum. In total, 19 compounds with high purity were obtained via automated multi-step preparative separation in a short period of time using this system, and their structures were comprehensively characterized by ESI-MS, (1)H NMR, and (13)C NMR. Including two new compounds, five isomers in two groups with identical HPLC and TLC retention values were also obtained and identified by 1D NMR and 2D NMR. This is the first report of an NPLC × RPLC system successfully applied in an on-line preparative process. This system not only solved the interfacing problem of mobile-phase immiscibility caused by NP and RP separation, it also exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Development and validation of high-performance liquid chromatography and high-performance thin-layer chromatography methods for the quantification of khellin in Ammi visnaga seed

    Science.gov (United States)

    Kamal, Abid; Khan, Washim; Ahmad, Sayeed; Ahmad, F. J.; Saleem, Kishwar

    2015-01-01

    Objective: The present study was used to design simple, accurate and sensitive reversed phase-high-performance liquid chromatography RP-HPLC and high-performance thin-layer chromatography (HPTLC) methods for the development of quantification of khellin present in the seeds of Ammi visnaga. Materials and Methods: RP-HPLC analysis was performed on a C18 column with methanol: Water (75: 25, v/v) as a mobile phase. The HPTLC method involved densitometric evaluation of khellin after resolving it on silica gel plate using ethyl acetate: Toluene: Formic acid (5.5:4.0:0.5, v/v/v) as a mobile phase. Results: The developed HPLC and HPTLC methods were validated for precision (interday, intraday and intersystem), robustness and accuracy, limit of detection and limit of quantification. The relationship between the concentration of standard solutions and the peak response was linear in both HPLC and HPTLC methods with the concentration range of 10–80 μg/mL in HPLC and 25–1,000 ng/spot in HPTLC for khellin. The % relative standard deviation values for method precision was found to be 0.63–1.97%, 0.62–2.05% in HPLC and HPTLC for khellin respectively. Accuracy of the method was checked by recovery studies conducted at three different concentration levels and the average percentage recovery was found to be 100.53% in HPLC and 100.08% in HPTLC for khellin. Conclusions: The developed HPLC and HPTLC methods for the quantification of khellin were found simple, precise, specific, sensitive and accurate which can be used for routine analysis and quality control of A. visnaga and several formulations containing it as an ingredient. PMID:26681890

  20. Sparse feature learning for instrument identification: Effects of sampling and pooling methods.

    Science.gov (United States)

    Han, Yoonchang; Lee, Subin; Nam, Juhan; Lee, Kyogu

    2016-05-01

    Feature learning for music applications has recently received considerable attention from many researchers. This paper reports on the sparse feature learning algorithm for musical instrument identification, and in particular, focuses on the effects of the frame sampling techniques for dictionary learning and the pooling methods for feature aggregation. To this end, two frame sampling techniques are examined that are fixed and proportional random sampling. Furthermore, the effect of using onset frame was analyzed for both of proposed sampling methods. Regarding summarization of the feature activation, a standard deviation pooling method is used and compared with the commonly used max- and average-pooling techniques. Using more than 47 000 recordings of 24 instruments from various performers, playing styles, and dynamics, a number of tuning parameters are experimented including the analysis frame size, the dictionary size, and the type of frequency scaling as well as the different sampling and pooling methods. The results show that the combination of proportional sampling and standard deviation pooling achieve the best overall performance of 95.62% while the optimal parameter set varies among the instrument classes.

  1. Pushing the speed limit in enantioselective supercritical fluid chromatography.

    Science.gov (United States)

    Regalado, Erik L; Welch, Christopher J

    2015-08-01

    Chromatographic enantioseparations on the order of a few seconds can be achieved by supercritical fluid chromatography using short columns packed with chiral stationary phases. The evolution of 'world record' speeds for the chromatographic separation of enantiomers has steadily dropped from an industry standard of 20-40 min just two decades ago, to a current ability to perform many enantioseparations in well under a minute. Improvements in instrument and column technologies enabled this revolution, but the ability to predict optimal separation time from an initial method development screening assay using the t(min cc) predictor greatly simplifies the development and optimization of high-speed chiral chromatographic separations. In this study, we illustrate how the use of this simple tool in combination with the workhorse technique of supercritical fluid chromatography on customized short chiral columns (1-2 cm length) allows us to achieve ultrafast enantioseparations of pharmaceutically relevant compounds on the 5-20 s scale, bringing the technique of high-throughput enantiopurity analysis out of the specialist realm and into the laboratories of most researchers. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Determination of methyldibromoglutaronitrile in cosmetic products by high-performance liquid chromatography with electrochemical detection. Method validation

    DEFF Research Database (Denmark)

    Rastogi, Suresh Chandra; Zachariae, Claus; Johansen, Jeanne D

    2004-01-01

    An increased frequency of contact allergy to methyldibromoglutaronitrile (MDBGN), a commonly used preservative in cosmetics and other consumer products, has been reported in recent years. A high-performance liquid chromatography (HPLC) method for the determination of MDBGN in cosmetic products has...

  3. Determination of methyldibromoglutaronitrile in cosmetic products by high-performance liquid chromatography with electrochemical detection. Method validation

    DEFF Research Database (Denmark)

    Rastogi, Suresh Chandra; Zachariae, Claus; Johansen, Jeanne D

    2004-01-01

    An increased frequency of contact allergy to methyldibromoglutaronitrile (MDBGN), a commonly used preservative in cosmetics and other consumer products, has been reported in recent years. A high-performance liquid chromatography (HPLC) method for the determination of MDBGN in cosmetic products ha...

  4. Calibration method based on direct radioactivity measurement for radioactive gas monitoring instruments

    International Nuclear Information System (INIS)

    Yoshida, Makoto; Ohi, Yoshihiro; Chida, Tohru; Wu, Youyang.

    1993-01-01

    A calibration method for radioactive gas monitoring instruments was studied. In the method, gaseous radioactivity standards were provided on the basis of the direct radioactivity measurement by the diffusion-in long proportional counter method (DLPC method). The radioactivity concentration of the gas mixture through a monitoring instrument was determined by sampling the known volume of the gas mixture into the proportional counter used for the DLPC method. Since oxygen in the gas mixture decreased the counting efficiency in a proportional counter, the influence on calibration was experimentally estimated. It was not serious and able to be easily corrected. By the present method, the relation between radioactivity concentration and ionization current was determined for a gas-flow ionization chamber with 1.5 l effective volume. It showed good agreement with the results in other works. (author)

  5. Development of an analytical instrumentation for determining U, Np and Pu

    International Nuclear Information System (INIS)

    Wu Jizong; Guo Kuisheng; Liu Huanliang

    1995-01-01

    An analytical instrumentation for determining U, Np and Pu in the solution of reprocessing factory are made. The principle of the instrumentation is based on that of flow injection analysis and ion chromatography. The instrumentation is composed of controlling box and working box, the distance between the two boxes is 1.5 m. Important quantity of impurity is permitted. The determination limit is 1 mg/l. The relative standard deviation is better than 5%. The instrumentation can be used in 1AF, 1AP and other many controlling points for determining U, Np and Pu

  6. Preparative separation of polyphenols from artichoke by polyamide column chromatography and high-speed counter-current chromatography

    International Nuclear Information System (INIS)

    Shu, Xikai; Wang, Mei; Liu, Daicheng; Wang, Daijie; Lin, Xiaojing; Liu, Jianhua; Wang, Xiao; Huang, Luqi

    2013-01-01

    An efficient method for the rapid separation and purification of polyphenols from artichoke by polyamide column chromatography in combination with high-speed counter-current chromatography (HSCCC) was successfully built. The crude ethanol extracts from dry artichoke were first pre-separated by polyamide column chromatography and divided in two parts as sample 1 and sample 2. Then, the samples were further separated by HSCCC and yielded 7.8 mg of chlorogenic acid (compound I), 24.5 mg of luteolin-7-O-β-D-rutinoside (compound II), 18.4 mg of luteolin-7-O-β-D-glucoside (compound III), and 33.4 mg of cynarin (compound IV) with purity levels of 92.0%, 98.2%, 98.5%, and 98.0%, respectively, as determined by high-performance liquid chromatography (HPLC) method. The chemical structures of these compounds were identified by electrospray ionization-mass spectrometry (ESI-MS) and nuclear magnetic resonance (NMR). (author)

  7. Preparative separation of polyphenols from artichoke by polyamide column chromatography and high-speed counter-current chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Xikai; Wang, Mei; Liu, Daicheng [College of Life Science, Shandong Normal University, Jinan, Shandong (China); Wang, Daijie; Lin, Xiaojing; Liu, Jianhua; Wang, Xiao; Huang, Luqi, E-mail: wxjn1998@126.com [Shandong Analysis and Test Center, Shandong Academy of Sciences, Jinan, Shandong (China)

    2013-09-01

    An efficient method for the rapid separation and purification of polyphenols from artichoke by polyamide column chromatography in combination with high-speed counter-current chromatography (HSCCC) was successfully built. The crude ethanol extracts from dry artichoke were first pre-separated by polyamide column chromatography and divided in two parts as sample 1 and sample 2. Then, the samples were further separated by HSCCC and yielded 7.8 mg of chlorogenic acid (compound I), 24.5 mg of luteolin-7-O-{beta}-D-rutinoside (compound II), 18.4 mg of luteolin-7-O-{beta}-D-glucoside (compound III), and 33.4 mg of cynarin (compound IV) with purity levels of 92.0%, 98.2%, 98.5%, and 98.0%, respectively, as determined by high-performance liquid chromatography (HPLC) method. The chemical structures of these compounds were identified by electrospray ionization-mass spectrometry (ESI-MS) and nuclear magnetic resonance (NMR). (author)

  8. A Workshop on Methods for Neutron Scattering Instrument Design. Introduction and Summary

    International Nuclear Information System (INIS)

    Hjelm, Rex P.

    1996-09-01

    The future of neutron and x-ray scattering instrument development and international cooperation was the focus of the workshop on ''Methods for Neutron Scattering Instrument Design'' September 23-25 at the E.O. Lawrence Berkeley National Laboratory. These proceedings are a collection of a portion of the invited and contributed presentations

  9. Calcium isotope fractionation in ion-exchange chromatography

    International Nuclear Information System (INIS)

    Russell, W.A.; Papanastassiou, D.A.

    1978-01-01

    Significant fractionation of the isotopes of calcium has been observed during elution through short ion-exchange columns packed with Dowex 50W-X8 resin. A double isotopic tracer was used to provide correction for instrumental fractionation effects. The absolute 40 Ca/ 44 Ca ratio is determined by this method to 0.05% and provides a measure of the fractionation of all Ca isotopes. It is found that the lighter isotopes are preferentially retained by the resin, with variations in 40 Ca/ 44 Ca between the first and last fractions of up to 1.1%. An estimate of the separation factor between batch solute and resin gives epsilon = 2.1 x 10 -4 . Details of the chemical or physical mechanisms causing isotope fractionation of Li, Na, Ca, and other elements during ion-exchange chromatography are not yet clear

  10. A simple, rapid and validated high-performance liquid chromatography method suitable for clinical measurements of human mercaptalbumin and non-mercaptalbumin.

    Science.gov (United States)

    Yasukawa, Keiko; Shimosawa, Tatsuo; Okubo, Shigeo; Yatomi, Yutaka

    2018-01-01

    Background Human mercaptalbumin and human non-mercaptalbumin have been reported as markers for various pathological conditions, such as kidney and liver diseases. These markers play important roles in redox regulations throughout the body. Despite the recognition of these markers in various pathophysiologic conditions, the measurements of human mercaptalbumin and non-mercaptalbumin have not been popular because of the technical complexity and long measurement time of conventional methods. Methods Based on previous reports, we explored the optimal analytical conditions for a high-performance liquid chromatography method using an anion-exchange column packed with a hydrophilic polyvinyl alcohol gel. The method was then validated using performance tests as well as measurements of various patients' serum samples. Results We successfully established a reliable high-performance liquid chromatography method with an analytical time of only 12 min per test. The repeatability (within-day variability) and reproducibility (day-to-day variability) were 0.30% and 0.27% (CV), respectively. A very good correlation was obtained with the results of the conventional method. Conclusions A practical method for the clinical measurement of human mercaptalbumin and non-mercaptalbumin was established. This high-performance liquid chromatography method is expected to be a powerful tool enabling the expansion of clinical usefulness and ensuring the elucidation of the roles of albumin in redox reactions throughout the human body.

  11. Evaluation of surface characteristics of rotary nickel-titanium instruments produced by different manufacturing methods.

    Science.gov (United States)

    Inan, U; Gurel, M

    2017-02-01

    Instrument fracture is a serious concern in endodontic practice. The aim of this study was to investigate the surface quality of new and used rotary nickel-titanium (NiTi) instruments manufactured by the traditional grinding process and twisting methods. Total 16 instruments of two rotary NiTi systems were used in this study. Eight Twisted Files (TF) (SybronEndo, Orange, CA, USA) and 8 Mtwo (VDW, Munich, Germany) instruments were evaluated. New and used of 4 experimental groups were evaluated using an atomic force microscopy (AFM). New and used instruments were analyzed on 3 points along a 3 mm. section at the tip of the instrument. Quantitative measurements according to the topographical deviations were recorded. The data were statistically analyzed with paired samples t-test and independent samples t-test. Mean root mean square (RMS) values for new and used TF 25.06 files were 10.70 ± 2.80 nm and 21.58 ± 6.42 nm, respectively, and the difference between them was statistically significant (P instruments produced by twisting method (TF 25.06) had better surface quality than the instruments produced by traditional grinding process (Mtwo 25.06 files).

  12. Instrumentation to Measure the Capacitance of Biosensors by Sinusoidal Wave Method

    Directory of Open Access Journals (Sweden)

    Pavan Kumar KATHUROJU

    2009-09-01

    Full Text Available Micro Controller based instrumentation to measure the capacitance of biosensors is developed. It is based on frequency domain technique with sinusoidal wave input. Changes in the capacitance of biosensor because of the analyte specific reaction are calculated by knowing the current flowing through the sample. A dedicated 8-bit microcontroller (AT89C52 and its associated peripherals are employed for the hardware and application specific software is developed in ‘C’ language. The paper describes the methodology, instrumentation details along with a specific application to glucose sensing. The measurements are conducted with glucose oxidase based capacitance biosensor and the obtained results are compared with the conventional method of sugar measurements using the UV-Visible spectroscopy (Phenol-Sulphuric acid assay method. Measurement accuracy of the instrument is found to be ± 5 %. Experiments are conducted on glucose sensor with different bias voltages. It is found that for bias voltages varying from 0.5 to 0.7 Volt, the measurements are good for this application.

  13. Validation of a method to determine methylmercury in fish tissues using gas chromatography

    International Nuclear Information System (INIS)

    Vega Bolannos, Luisa O.; Arias Verdes, Jose A.; Beltran Llerandi, Gilberto; Castro Diaz, Odalys; Moreno Tellez, Olga L.

    2000-01-01

    We validated a method to determine methylmercury in fish tissues using gas chromatography with an electron capture detector as described by the Association of Official Analytical Chemist (AOAC) International. The linear curve range was 0.02 to 1 g/ml and linear correlation coefficient was 0.9979. A 1 mg/kg methylmercury-contaminated fish sample was analyzed 20 times to determine repeatability of the method. The quantification limit was 0.16 mg/kg and detection limit was 0.06 ppm. Fish samples contaminated with 0.2 to 10 mg/kg methylmercury showed recovery indexes from 94.66 to 108.8%

  14. The Application of Resonance-Enhanced Multiphoton Ionization Technique in Gas Chromatography Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Adan Li

    2014-01-01

    Full Text Available Gas chromatography resonance-enhanced multiphoton ionization time-of-flight mass spectrometry (GC/REMPI-TOFMS using a nanosecond laser has been applied to analyze the 16 polycyclic aromatic hydrocarbons (PAHs. The excited-state lifetime, absorption characters, and energy of electronic states of the 16 PAHs were investigated to optimize the ionization yield. A river water sample pretreated by means of solid phase extraction was analyzed to evaluate the performance of the analytical instrument. The results suggested that REMPI is superior to electron impact ionization method for soft ionization and suppresses the background signal due to aliphatic hydrocarbons. Thus, GC/REMPI-TOFMS is a more reliable method for the determination of PAHs present in the environment.

  15. An introduction to planar chromatography and its application to natural products isolation.

    Science.gov (United States)

    Gibbons, Simon

    2012-01-01

    Thin-layer chromatography (TLC) is an easy, inexpensive, rapid, and the most widely used method for the analysis and isolation of small organic natural and synthetic products. It also has use in the biological evaluation of organic compounds, particularly in the areas of antimicrobial and antioxidant metabolites and for the evaluation of acetylcholinesterase inhibitors which have utility in the treatment of Alzheimer's disease. The ease and inexpensiveness of use of this technique, coupled with the ability to rapidly develop separation and bioassay protocols will ensure that TLC will be used for some considerable time alongside conventional instrumental methods. This chapter deals with the basic principles of TLC and describes methods for the analysis and isolation of natural products. Examples of methods for isolation of several classes of natural product are detailed and protocols for TLC bioassays are given.

  16. A method for the deliberate and deliberative selection of policy instrument mixes for climate change adaptation

    Directory of Open Access Journals (Sweden)

    Heleen L. P. Mees

    2014-06-01

    Full Text Available Policy instruments can help put climate adaptation plans into action. Here, we propose a method for the systematic assessment and selection of policy instruments for stimulating adaptation action. The multi-disciplinary set of six assessment criteria is derived from economics, policy, and legal studies. These criteria are specified for the purpose of climate adaptation by taking into account four challenges to the governance of climate adaptation: uncertainty, spatial diversity, controversy, and social complexity. The six criteria and four challenges are integrated into a step-wise method that enables the selection of instruments starting from a generic assessment and ending with a specific assessment of policy instrument mixes for the stimulation of a specific adaptation measure. We then apply the method to three examples of adaptation measures. The method's merits lie in enabling deliberate choices through a holistic and comprehensive set of adaptation specific criteria, as well as deliberative choices by offering a stepwise method that structures an informed dialog on instrument selection. Although the method was created and applied by scientific experts, policy-makers can also use the method.

  17. Simple, rapid, and sensitive liquid chromatography-fluorescence method for the quantification of tranexamic acid in blood

    NARCIS (Netherlands)

    Huertas-Pérez, José Fernando; Heger, Michal; Dekker, Henk; Krabbe, Hans; Lankelma, Jan; Ariese, Freek

    2007-01-01

    Tranexamic acid (TA) is a synthetic antifibrinolytic agent that is being considered as a candidate adjuvant drug for site-specific pharmaco-laser therapy of port wine stains. For drug utility studies, a high-performance liquid chromatography (HPLC)-fluorescence method was developed for the

  18. A simple high performance liquid chromatography method for analyzing paraquat in soil solution samples.

    Science.gov (United States)

    Ouyang, Ying; Mansell, Robert S; Nkedi-Kizza, Peter

    2004-01-01

    A high performance liquid chromatography (HPLC) method with UV detection was developed to analyze paraquat (1,1'-dimethyl-4,4'-dipyridinium dichloride) herbicide content in soil solution samples. The analytical method was compared with the liquid scintillation counting (LSC) method using 14C-paraquat. Agreement obtained between the two methods was reasonable. However, the detection limit for paraquat analysis was 0.5 mg L(-1) by the HPLC method and 0.05 mg L(-1) by the LSC method. The LSC method was, therefore, 10 times more precise than the HPLC method for solution concentrations less than 1 mg L(-1). In spite of the high detection limit, the UC (nonradioactive) HPLC method provides an inexpensive and environmentally safe means for determining paraquat concentration in soil solution compared with the 14C-LSC method.

  19. Supercritical fluid chromatography in drug analysis: a literature survey.

    Science.gov (United States)

    Salvador, A; Jaime, M A; Becerra, G; Guardia, M de L

    1996-08-01

    The applications of supercritical fluid chromatography to the analysis of drugs have been carefully revised from the literature compiled in the Analytical Abstracts until March 1994. Easy-to-read tables provide useful information about the state-of-the-art and possibilities offered by SFC in pharmaceutical analysis. The tables comprise extensive data about samples analyzed, pharmaceutical principles determined, solvents used and sample quantity injected, supercritical fluids and modifiers employed, injection system, instrumentation, experimental conditions for chromatographic separations (density, pressure, flow, temperature), characteristics of columns employed (type, support, length, diameter, particle film thickness, stationary phase), detectors, type of restrictors, and also some analytical features of the methods developed (such as retention time, resolution, sensitivity, limit of detection and relative standard deviation).

  20. Comparison of photoacoustic radiometry to gas chromatography/mass spectrometry methods for monitoring chlorinated hydrocarbons

    International Nuclear Information System (INIS)

    Sollid, J.E.; Trujillo, V.L.; Limback, S.P.; Woloshun, K.A.

    1996-01-01

    A comparison of two methods of gas chromatography mass spectrometry (GCMS) and a nondispersive infrared technique, photoacoustic radiometry (PAR), is presented in the context of field monitoring a disposal site. First is presented an historical account describing the site and early monitoring to provide an overview. The intent and nature of the monitoring program changed when it was proposed to expand the Radiological Waste Site close to the Hazardous Waste Site. Both the sampling methods and analysis techniques were refined in the course of this exercise

  1. Comprehensive two-dimensional gas chromatography applied to illicit drug analysis.

    Science.gov (United States)

    Mitrevski, Blagoj; Wynne, Paul; Marriott, Philip J

    2011-11-01

    Multidimensional gas chromatography (MDGC), and especially its latest incarnation--comprehensive two-dimensional gas chromatography (GC × GC)--have proved advantageous over and above classic one-dimensional gas chromatography (1D GC) in many areas of analysis by offering improved peak capacity, often enhanced sensitivity and, especially in the case of GC × GC, the unique feature of 'structured' chromatograms. This article reviews recent advances in MDGC and GC × GC in drug analysis with special focus on ecstasy, heroin and cocaine profiling. Although 1D GC is still the method of choice for drug profiling in most laboratories because of its simplicity and instrument availability, GC × GC is a tempting proposition for this purpose because of its ability to generate a higher net information content. Effluent refocusing due to the modulation (compression) process, combined with the separation on two 'orthogonal' columns, results in more components being well resolved and therefore being analytically and statistically useful to the profile. The spread of the components in the two-dimensional plots is strongly dependent on the extent of retention 'orthogonality' (i.e. the extent to which the two phases possess different or independent retention mechanisms towards sample constituents) between the two columns. The benefits of 'information-driven' drug profiling, where more points of reference are usually required for sample differentiation, are discussed. In addition, several limitations in application of MDGC in drug profiling, including data acquisition rate, column temperature limit, column phase orthogonality and chiral separation, are considered and discussed. Although the review focuses on the articles published in the last decade, a brief chronological preview of the profiling methods used throughout the last three decades is given.

  2. Application of the Instrumental Neutron Activation Analysis and High Performance Liquid Chromatography (HPLC) in the rare earth elements determination in reference geological materials

    International Nuclear Information System (INIS)

    Figueiredo, Ana M.G.; Moraes, Noemia M.P. de; Shihomatsu, Helena M.

    1997-01-01

    Instrumental Neutron Activation Analysis (INAA) and High Performance Liquid Chromatography (HPLC) were applied to the determination of rare earth elements (REE) in the geological reference materials AGV-1, G-2 and GSP-1 (USGS). Results obtained by both techniques showed good agreement with certified values, giving relative errors less than 10%. The La, Ce, Nd, Sm, Eu, Tb, Yb and Lu REE elements were determined. All the REE except Dy and Y were determined by HPLC. The reference material G94, employed in the International Proficiency Test for Analytical Geochemistry Laboratories (GeoTP1) was analysed. The results obtained are a contribution to REE contents in this sample. The INAA and HPLC application to the determination of REE in this kind of matrix is also discussed. (author). 10 refs., 1 fig., 5 tabs

  3. PHARMACEUTICAL AND BIOMEDICAL APPLICATIONS OF AFFINITY CHROMATOGRAPHY: RECENT TRENDS AND DEVELOPMENTS

    Science.gov (United States)

    Hage, David S.; Anguizola, Jeanethe A.; Bi, Cong; Li, Rong; Matsuda, Ryan; Papastavros, Efthimia; Pfaunmiller, Erika; Vargas, John; Zheng, Xiwei

    2012-01-01

    Affinity chromatography is a separation technique that has become increasingly important in work with biological samples and pharmaceutical agents. This method is based on the use of a biologically-related agent as a stationary phase to selectively retain analytes or to study biological interactions. This review discusses the basic principles behind affinity chromatography and examines recent developments that have occurred in the use of this method for biomedical and pharmaceutical analysis. Techniques based on traditional affinity supports are discussed, but an emphasis is placed on methods in which affinity columns are used as part of HPLC systems or in combination with other analytical methods. General formats for affinity chromatography that are considered include step elution schemes, weak affinity chromatography, affinity extraction and affinity depletion. Specific separation techniques that are examined include lectin affinity chromatography, boronate affinity chromatography, immunoaffinity chromatography, and immobilized metal ion affinity chromatography. Approaches for the study of biological interactions by affinity chromatography are also presented, such as the measurement of equilibrium constants, rate constants, or competition and displacement effects. In addition, related developments in the use of immobilized enzyme reactors, molecularly imprinted polymers, dye ligands and aptamers are briefly considered. PMID:22305083

  4. Nuclear medicine and imaging research (instrumentation and quantitative methods of evaluation)

    International Nuclear Information System (INIS)

    Beck, R.N.; Cooper, M.; Chen, C.T.

    1992-07-01

    This document is the annual progress report for project entitled ''Instrumentation and Quantitative Methods of Evaluation.'' Progress is reported in separate sections individually abstracted and indexed for the database. Subject areas reported include theoretical studies of imaging systems and methods, hardware developments, quantitative methods of evaluation, and knowledge transfer: education in quantitative nuclear medicine imaging

  5. A high-performance liquid chromatography method for the serotonin release assay is equivalent to the radioactive method.

    Science.gov (United States)

    Sono-Koree, N K; Crist, R A; Frank, E L; Rodgers, G M; Smock, K J

    2016-02-01

    The serotonin release assay (SRA) is considered the gold standard laboratory test for heparin-induced thrombocytopenia (HIT). The historic SRA method uses platelets loaded with radiolabeled serotonin to evaluate platelet activation by HIT immune complexes. However, a nonradioactive method is desirable. We report the performance characteristics of a high-performance liquid chromatography (HPLC) SRA method. We validated the performance characteristics of an HPLC-SRA method, including correlation with a reference laboratory using the radioactive method. Serotonin released from reagent platelets was quantified by HPLC using fluorescent detection. Results were expressed as % release and classified as positive, negative, or indeterminate based on previously published cutoffs. Serum samples from 250 subjects with suspected HIT were tested in the HPLC-SRA and with the radioactive method. Concordant classifications were observed in 230 samples (92%). Sera from 41 healthy individuals tested negative. Between-run imprecision studies showed standard deviation of performance characteristics, equivalent to the historic radioactive method, but avoids the complexities of working with radioactivity. © 2015 John Wiley & Sons Ltd.

  6. Analysis of Trace Pharmaceuticals and Related Compounds in Municipal Wastewaters by Preconcentration, Chromatography, Derivatization, and Separation Methods

    Directory of Open Access Journals (Sweden)

    Petra Camilla Lindholm

    2014-05-01

    Full Text Available A significant portion of pharmaceuticals and other organic chemicals consumed by people and animals are released into municipal wastewater treatment plants. Most of them are degraded during the wastewater treatment processes, but some of them degrade only partially and may be widely transported and dispersed into the aquatic environment. This is why efficient and fast analytical methods are needed for detection of organic compounds in wastewaters at trace levels. Because wastewaters often consist of complex matrices and high-molecular mass materials, e.g., lignocellulosic biomass, which may bring challenges to the sample preparation procedures, efficient pre-concentration methods such as solid phase extraction (SPE solid phase microextraction (SPME, or single drop microextraction (SDME are needed. The most common analysis methods are gas chromatography (GC and liquid chromatography (LC coupled with tandem mass spectrometry (MS/MS. The aim of this review is to give an overview of chromatographic and spectroscopic methods when characterizing low- and medium-molecular weight organic pollutants, mainly focusing on pharmaceuticals, biocides, and personal care products in environmental matrices.

  7. Extending the frontiers of mass spectrometric instrumentation and methods

    Energy Technology Data Exchange (ETDEWEB)

    Schieffer, Gregg Martin [Iowa State Univ., Ames, IA (United States)

    2010-01-01

    The focus of this dissertation is two-fold: developing novel analysis methods using mass spectrometry and the implementation and characterization of a novel ion mobility mass spectrometry instrumentation. The novel mass spectrometry combines ion trap for ion/ion reactions coupled to an ion mobility cell. The long term goal of this instrumentation is to use ion/ion reactions to probe the structure of gas phase biomolecule ions. The three ion source - ion trap - ion mobility - qTOF mass spectrometer (IT - IM - TOF MS) instrument is described. The analysis of the degradation products in coal (Chapter 2) and the imaging plant metabolites (Appendix III) fall under the methods development category. These projects use existing commercial instrumentation (JEOL AccuTOF MS and Thermo Finnigan LCQ IT, respectively) for the mass analysis of the degraded coal products and the plant metabolites, respectively. The coal degradation paper discusses the use of the DART ion source for fast and easy sample analysis. The sample preparation consisted of a simple 50 fold dilution of the soluble coal products in water and placing the liquid in front of the heated gas stream. This is the first time the DART ion source has been used for analysis of coal. Steven Raders under the guidance of John Verkade came up with the coal degradation projects. Raders performed the coal degradation reactions, worked up the products, and sent them to me. Gregg Schieffer developed the method and wrote the paper demonstrating the use of the DART ion source for the fast and easy sample analysis. The plant metabolite imaging project extends the use of colloidal graphite as a sample coating for atmospheric pressure LDI. DC Perdian and I closely worked together to make this project work. Perdian focused on building the LDI setup whereas Schieffer focused on the MSn analysis of the metabolites. Both Perdian and I took the data featured in the paper. Perdian was the primary writer of the paper and used it as a

  8. Determination of 2-naphthylamine in urine by a novel reversed-phase high-performance liquid chromatography method

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Poulsen, O M; Christensen, J M

    1992-01-01

    A high-performance liquid chromatographic method for the determination of 2-naphthylamine in urine using fluorescence detection was developed. The method validation analysis showed the method to be in analytical control, i.e. the distribution of the difference between the observed and true values...... of the method evaluation samples did not deviate significantly from the normal distribution. The recovery of the method was 85%. The entire run time of chromatography was 10 min using isocratic elution (acetonitrile-water, 35:65), and the retention time for 2-naphthylamine was 5.8 min. The relative short time...

  9. A simple, sensitive and rapid isocratic reversed-phase high-performance liquid chromatography method for determination and stability study of curcumin in pharmaceutical samples

    Science.gov (United States)

    Amanolahi, Farjad; Mohammadi, Ali; Kazemi Oskuee, Reza; Nassirli, Hooriyeh; Malaekeh-Nikouei, Bizhan

    2017-01-01

    Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55, v/v, pH 3.5), C18 column (150 mm×4.6 mm×5 µm particle size) and a flow rate of 1 ml/min in ambient condition and total retention time of 17 min. The volume of injection was set at 20 µl and detection was recorded at 425 nm. The robustness of the method was examined by changing the mobile phase composition, mobile phase pH, and flow rate. Results: The method was validated with respect to precision, accuracy and linearity in a concentration range of 2-100 µg/ml. The limit of detection (LOD) and limit of quantification (LOQ) were 0.25 and 0.5 µg/ml, respectively. The percentage of recovery was 98.9 to 100.5 with relative standard deviation (RSD) < 0.638%. Conclusion: The method was found to be simple, sensitive and rapid for determination of curcumin in pharmaceutical samples and had enough sensitivity to detect degradation product of curcumin produced under photolysis and hydrolysis stress condition. PMID:29062806

  10. FJ-2207 measuring instrument detection pipe surface a level of pollution method

    International Nuclear Information System (INIS)

    Wang Jiangong

    2010-01-01

    On the pipe surface contamination were detected α level of pollution is a frequently encountered dose-detection work. Because the pipeline surface arc, while the measuring probe for the plane, which for accurate measurement difficult. In this paper, on the FJ-2207-type pipe surface contamination measuring instrument measuring pollution levels in the α method was studied. Introduced the FJ-2207 measuring instrument detection pipe surface α pollution levels. Studied this measuring instrument on the same sources of surface, plane α level of radioactivity measured differences in the results obtained control of the apparatus when the direct measurement of the surface correction factor, and gives 32-216 specifications commonly used pipe direct measurement of the amendment factor. Convenient method, test results are reliable for the accurate measurement of pipe pollution levels in the surface of α as a reference and learning. (authors)

  11. A method for fast determination of psoralens in oral solutions of phytomedicines using liquid chromatography.

    Science.gov (United States)

    Pires, Adriana Elias; Honda, Neli Kiko; Cardoso, Cláudia Andréa Lima

    2004-10-29

    A method for sample preparation and analysis by high performance liquid chromatography with UV detection (HPLC-UV) has been developed for routine analysis of psoralen and bergapten, photosensitizing compounds, in oral solutions of phytomedicines employed in Brazil for some illnesses. The linearity, accuracy, the inter- and intra-day precision of the procedure were evaluated. Calibration curves for psoralen and bergapten were linear in the range of 1.0-600.0 microg ml(-1) and 1.0-400.0 microg ml(-1) respectively. The recoveries of the psoralens in the oral solutions analysed were 94.43-99.97%. The percentage coefficient of variation (CV) of the quantitative analysis of the psoralens in the products analysis was within 5%. In inter-equipment study was employed gas chromatography-flame ionization (CG-FID) detection.

  12. New methods of magnet-based instrumentation for NOTES.

    Science.gov (United States)

    Magdeburg, Richard; Hauth, Daniel; Kaehler, Georg

    2013-12-01

    Laparoscopic surgery has displaced open surgery as the standard of care for many clinical conditions. NOTES has been described as the next surgical frontier with the objective of incision-free abdominal surgery. The principal challenge of NOTES procedures is the loss of triangulation and instrument rigidity, which is one of the fundamental concepts of laparoscopic surgery. To overcome these problems necessitates the development of new instrumentation. material and methods: We aimed to assess the use of a very simple combination of internal and external magnets that might allow the vigorous multiaxial traction/counter-traction required in NOTES procedures. The magnet retraction system consisted of an external magnetic assembly and either small internal magnets attached by endoscopic clips to the designated tissue (magnet-clip-approach) or an endoscopic grasping forceps in a magnetic deflector roll (magnet-trocar-approach). We compared both methods regarding precision, time and efficacy by performing transgastric partial uterus resections with better results for the magnet-trocar-approach. This proof-of-principle animal study showed that the combination of external and internal magnets generates sufficient coupling forces at clinically relevant abdominal wall thicknesses, making them suitable for use and evaluation in NOTES procedures, and provides the vigorous multiaxial traction/counter-traction required by the lack of additional abdominal trocars.

  13. Osteoblast cell membrane chromatography coupled with liquid chromatography and time-of-flight mass spectrometry for screening specific active components from traditional Chinese medicines.

    Science.gov (United States)

    Wang, Nani; Zhang, Qiaoyan; Xin, Hailiang; Shou, Dan; Qin, Luping

    2017-11-01

    A method using osteoblast membrane chromatography coupled with liquid chromatography and time-of-flight mass spectrometry was developed to recognize and identify the specific active components from traditional Chinese medicines. Primary rat osteoblasts were used for the preparation of the stationary phase in the cell chromatography method. Retention components from the cell chromatography were collected and analyzed by liquid chromatography with time-of-flight mass spectrometry. This method was applied in screening active components from extracts of four traditional Chinese medicines. In total, 24 potentially active components with different structures were retained by osteoblast cell chromatography. There were five phenolic glucosides and one triterpenoid saponin from Curculigo orchioides Gaertn, two organic acids and ten flavonoids from Epimedium sagittatum Maxim, one phthalide compound and one organic acid from Angelica sinensis Diels, and two flavonoids and two saponins from Anemarrhena asphodeloides Bunge. Among those, four components (icariin, curculigoside, ferulaic acid, and timosaponin BII) were used for in vitro pharmacodynamics validation. They significantly increased the osteoblast proliferation, alkaline phosphatase activity, levels of bone gla protein and collagen type 1, and promoted mineralized nodule formation. The developed method was an effective screening method for finding active components from complex medicines that act on bone diseases. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Method to deterministically study photonic nanostructures in different experimental instruments

    NARCIS (Netherlands)

    Husken, B.H.; Woldering, L.A.; Blum, Christian; Tjerkstra, R.W.; Vos, Willem L.

    2009-01-01

    We describe an experimental method to recover a single, deterministically fabricated nanostructure in various experimental instruments without the use of artificially fabricated markers, with the aim to study photonic structures. Therefore, a detailed map of the spatial surroundings of the

  15. Detection of radiation-induced hydrocarbons in Camembert irradiated before and after the maturing process-comparison of florisil column chromatography and on-line coupled liquid chromatography-gas chromatography

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Bögl, K.W.; Schreiber, G.A.

    1995-01-01

    The influence of the maturing process on the detection of radiation-induced volatile hydrocarbons in the fat of Camembert has been investigated. Two analytical methods for separation of the hydrocarbon fraction from the lipid were applied: Florisil column chromatography with subsequent gas chromatographic-mass spectrometric (GC-MS) determination as well as on-line coupled liquid chromatography-GC-MS. The maturing process had no influence on the detection of radiation-induced volatiles. Comparable results were achieved with both analytical methods. However, preference is given to the more effective on-line coupled LC-GC method

  16. Compound-Specific Chlorine Isotope Analysis of Tetrachloromethane and Trichloromethane by Gas Chromatography-Isotope Ratio Mass Spectrometry vs Gas Chromatography-Quadrupole Mass Spectrometry: Method Development and Evaluation of Precision and Trueness.

    Science.gov (United States)

    Heckel, Benjamin; Rodríguez-Fernández, Diana; Torrentó, Clara; Meyer, Armin; Palau, Jordi; Domènech, Cristina; Rosell, Mònica; Soler, Albert; Hunkeler, Daniel; Elsner, Martin

    2017-03-21

    Compound-specific chlorine isotope analysis of tetrachloromethane (CCl 4 ) and trichloromethane (CHCl 3 ) was explored by both, gas chromatography-isotope ratio mass spectrometry (GC-IRMS) and GC-quadrupole MS (GC-qMS), where GC-qMS was validated in an interlaboratory comparison between Munich and Neuchâtel with the same type of commercial GC-qMS instrument. GC-IRMS measurements analyzed CCl isotopologue ions, whereas GC-qMS analyzed the isotopologue ions CCl 3 , CCl 2 , CCl (of CCl 4 ) and CHCl 3 , CHCl 2 , CHCl (of CHCl 3 ), respectively. Lowest amount dependence (good linearity) was obtained (i) in H-containing fragment ions where interference of 35 Cl- to 37 Cl-containing ions was avoided; (ii) with tuning parameters favoring one predominant rather than multiple fragment ions in the mass spectra. Optimized GC-qMS parameters (dwell time 70 ms, 2 most abundant ions) resulted in standard deviations of 0.2‰ (CHCl 3 ) and 0.4‰ (CCl 4 ), which are only about twice as large as 0.1‰ and 0.2‰ for GC-IRMS. To compare also the trueness of both methods and laboratories, samples from CCl 4 and CHCl 3 degradation experiments were analyzed and calibrated against isotopically different reference standards for both CCl 4 and CHCl 3 (two of each). Excellent agreement confirms that true results can be obtained by both methods provided that a consistent set of isotopically characterized reference materials is used.

  17. Efficient methods for isolating five phytochemicals from Gentiana macrophylla using high-performance countercurrent chromatography.

    Science.gov (United States)

    Rho, Taewoong; Jung, Mila; Lee, Min Won; Chin, Young-Won; Yoon, Kee Dong

    2016-12-01

    Efficient high-performance countercurrent chromatography methods were developed to isolate five typical compounds from the extracts of Gentiana macrophylla. n-Butanol-soluble extract of G. macrophylla contained three hydrophilic iridoids, loganic acid (1), swertiamarin (2) and gentiopicroside (3), and a chromene derivative, macrophylloside D (4) which were successfully isolated by flow rate gradient (1.5 mL/min in 0-60 min, 5.0 mL/min in 60-120 min), and consecutive flow rate gradient HPCCC using n-butanol/0.1% aqueous trifluoroacetic acid (1:1, v/v, normal phase mode) system. The yields of 1-4 were 22, 16, 122, and 6 mg, respectively, with purities over 97% in a flow rate gradient high-performance countercurrent chromatography, and consecutive flow rate gradient high-performance countercurrent chromatography gave 1, 2, 3 (54, 41, 348 mg, respectively, purities over 97%) and 4 (13 mg, purity at 95%) from 750 mg of sample. The main compound in methylene chloride soluble extract, 2-methoxyanofinic acid, was successfully separated by n-hexane/ethyl acetate/methanol/water (4:6:4:6, v/v/v/v, flow-rate: 4 mL/min, reversed phase mode) condition. The structures of five isolates were elucidated by 1 H, 13 C NMR and ESI-Q-TOF-MS spectroscopic data which were compared with previously reported values. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. High performance liquid chromatography-charged aerosol detection applying an inverse gradient for quantification of rhamnolipid biosurfactants.

    Science.gov (United States)

    Behrens, Beate; Baune, Matthias; Jungkeit, Janek; Tiso, Till; Blank, Lars M; Hayen, Heiko

    2016-07-15

    A method using high performance liquid chromatography coupled to charged-aerosol detection (HPLC-CAD) was developed for the quantification of rhamnolipid biosurfactants. Qualitative sample composition was determined by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The relative quantification of different derivatives of rhamnolipids including di-rhamnolipids, mono-rhamnolipids, and their precursors 3-(3-hydroxyalkanoyloxy)alkanoic acids (HAAs) differed for two compared LC-MS instruments and revealed instrument dependent responses. Our here reported HPLC-CAD method provides uniform response. An inverse gradient was applied for the absolute quantification of rhamnolipid congeners to account for the detector's dependency on the solvent composition. The CAD produces a uniform response not only for the analytes but also for structurally different (nonvolatile) compounds. It was demonstrated that n-dodecyl-β-d-maltoside or deoxycholic acid can be used as alternative standards. The method of HPLC-ultra violet (UV) detection after a derivatization of rhamnolipids and HAAs to their corresponding phenacyl esters confirmed the obtained results but required additional, laborious sample preparation steps. Sensitivity determined as limit of detection and limit of quantification for four mono-rhamnolipids was in the range of 0.3-1.0 and 1.2-2.0μg/mL, respectively, for HPLC-CAD and 0.4 and 1.5μg/mL, respectively, for HPLC-UV. Linearity for HPLC-CAD was at least 0.996 (R(2)) in the calibrated range of about 1-200μg/mL. Hence, the here presented HPLC-CAD method allows absolute quantification of rhamnolipids and derivatives. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Identification of key aromatic compounds in Congou black tea by PLSR with variable importance of projection scores and gas chromatography-mass spectrometry/gas chromatography-olfactometry.

    Science.gov (United States)

    Mao, Shihong; Lu, Changqi; Li, Meifeng; Ye, Yulong; Wei, Xu; Tong, Huarong

    2018-04-13

    Gas chromatography-olfactometry (GC-O) is the most frequently used method to estimate the sensory contribution of single odorant, but disregards the interactions between volatiles. In order to select the key volatiles responsible for the aroma attributes of Congou black tea (Camellia sinensis), instrumental, sensory and multivariate statistical approaches were applied. By sensory analysis, nine panelists developed 8 descriptors, namely, floral, sweet, fruity, green, roasted, oil, spicy, and off-odor. Linalool, (E)-furan linalool oxide, (Z)-pyran linalool oxide, methyl salicylate, β-myrcene, phenylethyl alcohol which identified from the most representative samples by GC-O procedure, were the essential aroma-active compounds in the formation of basic Congou black tea aroma. In addition, 136 volatiles were identified by gas chromatography-mass spectrometry (GC-MS), among which 55 compounds were determined as the key factors for the six sensory attributes by partial least-square regression (PLSR) with variable importance of projection (VIP) scores. Our results demonstrated that HS-SPME/GC-MS/GC-O was a fast approach for isolation and quantification aroma-active compounds. PLSR method was also considered to be a useful tool in selecting important variables for sensory attributes. These two strategies allowed us to comprehensively evaluate the sensorial contribution of single volatile from different perspectives, can be applied to related products for comprehensive quality control. This article is protected by copyright. All rights reserved.

  20. Determination of seven sunscreen agents and two ultraviolet stabilizers in skin care products using ultra-performance liquid chromatography.

    Science.gov (United States)

    Gowell, Aimee; Habel, John; Weiss, Caryn; Parkanzky, Paul

    2015-01-01

    Ultraviolet radiation (UVR) is a well-known environmental carcinogen. Protection against UVR exposure has resulted in an increasing number of sunscreen agents being incorporated into a greater variety of cosmetic formulations including moisturizing lotions, color cosmetics, and skin care creams. Meanwhile, global regulation of sun care products is changing. New guidelines for sunscreen efficacy have resulted in a shift in product formulation that requires sunscreen products to provide broad spectrum UV protection. Since not all sunscreen ingredients protect against both UVA and UVB radiation, most sun care products require a combination of sunscreen agents. This article describes a new method for simultaneous separation and quantitation of seven organic sunscreens and two UV stabilizers using ultra-performance liquid chromatography. This method is capable of resolving all nine analytes, and has been validated for selectivity, precision, and accuracy. Because of the use of core-shell column technology, the separation is also achieved at back pressures compatible with conventional high-performance liquid chromatography instrumentation.

  1. Multiplex gas chromatography

    Science.gov (United States)

    Valentin, Jose R.

    1990-01-01

    The principles of the multiplex gas chromatography (GC) technique, which is a possible candidate for chemical analysis of planetary atmospheres, are discussed. Particular attention is given to the chemical modulators developed by present investigators for multiplex GC, namely, the thermal-desorption, thermal-decomposition, and catalytic modulators, as well as to mechanical modulators. The basic technique of multiplex GC using chemical modulators and a mechanical modulator is demonstrated. It is shown that, with the chemical modulators, only one gas stream consisting of the carrier in combination with the components is being analyzed, resulting in a simplified instrument that requires relatively few consumables. The mechanical modulator demonstrated a direct application of multiplex GC for the analysis of gases in atmosphere of Titan at very low pressures.

  2. 30 CFR 75.1719-3 - Methods of measurement; light measuring instruments.

    Science.gov (United States)

    2010-07-01

    ... being measured and a sufficient distance from the surface to allow the light sensing element in the... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Methods of measurement; light measuring... § 75.1719-3 Methods of measurement; light measuring instruments. (a) Compliance with § 75.1719-1(d...

  3. Recent advances of liquid chromatography-(tandem) mass spectrometry in clinical and forensic toxicology.

    Science.gov (United States)

    Peters, Frank T

    2011-01-01

    Liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) has become increasingly important in clinical and forensic toxicology as well as doping control and is now a robust and reliable technique for routine analysis in these fields. In recent years, methods for LC-MS(/MS)-based systematic toxicological analysis using triple quadrupole or ion trap instruments have been considerably improved and a new screening approach based on high-resolution MS analysis using benchtop time-of-flight MS instruments has been developed. Moreover, many applications for so-called multi-target screening and/or quantification of drugs, poisons, and or their metabolites in various biomatrices have been published. The present paper will provide an overview and discuss these recent developments focusing on the literature published after 2006. Copyright © 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Capillary gas-solid chromatography

    International Nuclear Information System (INIS)

    Berezkin, V.G.

    1996-01-01

    Modern state of gas adsorption chromatography in open capillary columns has been analyzed. The history of the method development and its role in gas chromatography, ways to construct open adsorptional capillary columns, foundations of the theory of retention and washing of chromatographic regions in gas adsorption capillary columns have been considered. The fields is extensively and for analyzing volatile compounds of different isotopic composition, inorganic and organic gases, volatile organic polar compounds, aqueous solutions of organic compounds. Separation of nuclear-spin isomers and isotopes of hydrogen is the first illustrative example of practical application of the adsorption capillary chromatography. It is shown that duration of protium and deuterium nuclear isomers may be reduced if the column temperature is brought to 47 K

  5. Chromatography in Industry

    Science.gov (United States)

    Schoenmakers, Peter

    2009-07-01

    This review focuses on the chromatography research that has been carried out within industry or in close cooperation with industry and that has been reported in the scientific literature between 2006 and mid-2008. Companies in the health care sector, such as pharmaceutical and biotechnology companies, are the largest contributors. Industrial research seems to take place in an open environment in cooperation with academia, peer companies, and institutions. Industry appears ready to embrace new technologies as they emerge, but they focus strongly on making chromatography work robustly, reliably, rapidly, and automatically. “Hyphenated” systems that incorporate on-line sample-preparation techniques and mass-spectrometric detection are the rule rather than the exception. Various multidimensional separation methods are finding numerous applications. Strategies aimed at speeding up the development of new chromatographic methods remain the focus of attention. Also, there is a clear trend toward exploring chromatographic methods for parallel processing along with other strategies for high-throughput analysis.

  6. Analysis of lignans in Magnoliae Flos by turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Xuan; Chen, Cen; Ye, Xiaolan; Song, Fenyun; Fan, Guorong; Wu, Fuhai

    2016-04-01

    In this study, a method coupling turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry was developed for analyzing the lignans in Magnoliae Flos. By the online pretreatment of turbulent flow chromatography solid-phase extraction, the impurities removal and analytes concentration were automatically processed, and the lignans were separated rapidly and well. Seven lignans of Magnoliae Flos including epieudesmin, magnolin, 1-irioresinol-B-dimethyl ether, epi-magnolin, fargesin aschantin, and demethoxyaschantin were identified by comparing their retention behavior, UV spectra, and mass spectra with those of reference substances or literature data. The developed method was validated, and the good results showed that the method was not only automatic and rapid, but also accurate and reliable. The turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry method holds a high potential to become an effective method for the quality control of lignans in Magnoliae Flos and a useful tool for the analysis of other complex mixtures. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Tundish Cover Flux Thickness Measurement Method and Instrumentation Based on Computer Vision in Continuous Casting Tundish

    Directory of Open Access Journals (Sweden)

    Meng Lu

    2013-01-01

    Full Text Available Thickness of tundish cover flux (TCF plays an important role in continuous casting (CC steelmaking process. Traditional measurement method of TCF thickness is single/double wire methods, which have several problems such as personal security, easily affected by operators, and poor repeatability. To solve all these problems, in this paper, we specifically designed and built an instrumentation and presented a novel method to measure the TCF thickness. The instrumentation was composed of a measurement bar, a mechanical device, a high-definition industrial camera, a Siemens S7-200 programmable logic controller (PLC, and a computer. Our measurement method was based on the computer vision algorithms, including image denoising method, monocular range measurement method, scale invariant feature transform (SIFT, and image gray gradient detection method. Using the present instrumentation and method, images in the CC tundish can be collected by camera and transferred to computer to do imaging processing. Experiments showed that our instrumentation and method worked well at scene of steel plants, can accurately measure the thickness of TCF, and overcome the disadvantages of traditional measurement methods, or even replace the traditional ones.

  8. Use and practice of achiral and chiral supercritical fluid chromatography in pharmaceutical analysis and purification.

    Science.gov (United States)

    Lemasson, Elise; Bertin, Sophie; West, Caroline

    2016-01-01

    The interest of pharmaceutical companies for complementary high-performance chromatographic tools to assess a product's purity or enhance this purity is on the rise. The high-throughput capability and economic benefits of supercritical fluid chromatography, but also the "green" aspect of CO2 as the principal solvent, render supercritical fluid chromatography very attractive for a wide range of pharmaceutical applications. The recent reintroduction of new robust instruments dedicated to supercritical fluid chromatography and the progress in stationary phase technology have also greatly benefited supercritical fluid chromatography. Additionally, it was shown several times that supercritical fluid chromatography could be orthogonal to reversed-phase high-performance liquid chromatography and could efficiently compete with it. Supercritical fluid chromatography is an adequate tool for small molecules of pharmaceutical interest: synthetic intermediates, active pharmaceutical ingredients, impurities, or degradation products. In this review, we first discuss about general chromatographic conditions for supercritical fluid chromatography analysis to better suit compounds of pharmaceutical interest. We also discuss about the use of achiral and chiral supercritical fluid chromatography for analytical purposes and the recent applications in these areas. The use of preparative supercritical fluid chromatography by pharmaceutical companies is also covered. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Comprehensive two-dimensional gas chromatography for the analysis of organohalogenated micro-contaminants

    NARCIS (Netherlands)

    Korytar, P.; Haglund, P.; Boer, de J.; Brinkman, U.A.Th.

    2006-01-01

    We explain the principles of comprehensive two-dimensional gas chromatography (GC × GC), and discuss key instrumental aspects - with emphasis on column combinations and mass spectrometric detection. As the main item of interest, we review the potential of GC × GC for the analysis of

  10. Instrumentation and quantitative methods of evaluation. Progress report, January 15-September 14, 1986

    International Nuclear Information System (INIS)

    Beck, R.N.

    1986-09-01

    This document reports progress under grant entitled ''Instrumentation and Quantitative Methods of Evaluation.'' Individual reports are presented on projects entitled the physical aspects of radionuclide imaging, image reconstruction and quantitative evaluation, PET-related instrumentation for improved quantitation, improvements in the FMI cyclotron for increased utilization, and methodology for quantitative evaluation of diagnostic performance

  11. A simple method for the measurement of radioactivity of samples separated by gas chromatography

    International Nuclear Information System (INIS)

    Farkas, T.

    1981-01-01

    Gas chromatographs with flame ionization detector can be used to determine the radioactivity ( 14 C) of separated peaks. After a suitable change in the detector output the combustion product 14 CO 2 can be trapped by hyamine hydroxyde and measured by liquid scintigraphy. 90% of peak activity can be collected and measured, thus the method can be applied to determine the distribution and specific radioactivity of the components separated by gas chromatography. (author)

  12. Intercomparison of two comparative reactivity method instruments inf the Mediterranean basin during summer 2013

    Science.gov (United States)

    Zannoni, N.; Dusanter, S.; Gros, V.; Sarda Esteve, R.; Michoud, V.; Sinha, V.; Locoge, N.; Bonsang, B.

    2015-09-01

    The hydroxyl radical (OH) plays a key role in the atmosphere, as it initiates most of the oxidation processes of volatile organic compounds (VOCs), and can ultimately lead to the formation of ozone and secondary organic aerosols (SOAs). There are still uncertainties associated with the OH budget assessed using current models of atmospheric chemistry and direct measurements of OH sources and sinks have proved to be valuable tools to improve our understanding of the OH chemistry. The total first order loss rate of OH, or total OH reactivity, can be directly measured using three different methods, such as the following: total OH loss rate measurement, laser-induced pump and probe technique and comparative reactivity method. Observations of total OH reactivity are usually coupled to individual measurements of reactive compounds in the gas phase, which are used to calculate the OH reactivity. Studies using the three methods have highlighted that a significant fraction of OH reactivity is often not explained by individually measured reactive compounds and could be associated to unmeasured or unknown chemical species. Therefore accurate and reproducible measurements of OH reactivity are required. The comparative reactivity method (CRM) has demonstrated to be an advantageous technique with an extensive range of applications, and for this reason it has been adopted by several research groups since its development. However, this method also requires careful corrections to derive ambient OH reactivity. Herein we present an intercomparison exercise of two CRM instruments, CRM-LSCE (Laboratoire des Sciences du Climat et de l'Environnement) and CRM-MD (Mines Douai), conducted during July 2013 at the Mediterranean site of Ersa, Cape Corsica, France. The intercomparison exercise included tests to assess the corrections needed by the two instruments to process the raw data sets as well as OH reactivity observations. The observation was divided in three parts: 2 days of plant

  13. Creating New Technologists of Research in the 1960s: The Case of the Reproduction of Automated Chromatography Specialists and Practitioners

    Science.gov (United States)

    Gerontas, Apostolos

    2014-01-01

    Chromatographic instrumentation has been really influential in shaping the modern chemical practice, and yet it has been largely overlooked by history of science.Gas chromatography in the 1960s was considered the analytical technique closer to becoming dominant, and being the first automated chromatography set the standards that all the subsequent…

  14. Purification of human albumin by the combination of the method of Cohn with liquid chromatography

    Directory of Open Access Journals (Sweden)

    Tanaka K.

    1998-01-01

    Full Text Available Large volumes of plasma can be fractionated by the method of Cohn at low cost. However, liquid chromatography is superior in terms of the quality of the product obtained. In order to combine the advantages of each method, we developed an integrated method for the production of human albumin and immunoglobulin G (IgG. The cryoprecipitate was first removed from plasma for the production of factor VIII and the supernatant of the cryoprecipitate was fractionated by the method of Cohn. The first precipitate, containing fractions (F-I + II + III, was used for the production of IgG by the chromatographic method (see Tanaka K et al. (1998 Brazilian Journal of Medical and Biological Research, 31: 1375-1381. The supernatant of F-I + II + III was submitted to a second precipitation and F-IV was obtained and discarded. Albumin was obtained from the supernatant of the precipitate F-IV by liquid chromatography, ion-exchange on DEAE-Sepharose FF, filtration through Sephacryl S-200 HR and introduction of heat treatment for fatty acid precipitation. Viral inactivation was performed by pasteurization at 60ºC for 10 h. The albumin product obtained by the proposed procedure was more than 99% pure for the 15 lots of albumin produced, with a mean yield of 25.0 ± 0.5 g/l plasma, containing 99.0 to 99.3% monomer, 0.7 to 1.0% dimers, and no polymers. Prekallikrein activator levels were <=5 IU/ml. This product satisfies the requirements of the 1997 Pharmacopée Européenne.

  15. Extraction chromatography of actinides

    International Nuclear Information System (INIS)

    Muller, W.

    1978-01-01

    Extraction chromatography of actinides in the oxidation state from 2 to 6 is reviewed. Data on using neutral (tbp), basic (substituted ammonium salts) and acidic [di-(2-ethylhexyl)-phosphoric acid (D2EHPA)] extracting agents ketones, esters, alcohols and β-diketones in this method are given. Using the example of actinide separation using D2EHPA, discussed are factors influencing the efficiency of their chromatography separation (nature and particle size of the carrier materials, extracting agents amount on the carrier, temperature and elution rate)

  16. Pre-staining thin layer chromatography method for amino acid ...

    African Journals Online (AJOL)

    Jane

    2010-12-13

    Dec 13, 2010 ... inexpensive and the results obtained were clean and reproducible. However, it is suitable for the high throughput screening of amino acid-producing strains. Key words: Thin layer chromatography, pre-staining, amino acid detection. INTRODUCTION. Several analytical techniques have been often used for.

  17. Sensitive method for the analysis of carbohydrates by gas chromatography of 3H-labeled alditol acetates

    International Nuclear Information System (INIS)

    Prehm, P.; Scheid, A.

    1978-01-01

    A highly sensitive method has been developed for the analysis of carbohydrates from glycoproteins or lipopolysaccharides. The method is based on labeling the carbohydrates with [ 3 H] sodium borohydride, acetylating the resulting alditols and separating them by gas chromatography. The gas effluent is fractionated by trapping on silicone-coated glass beads and the amount of radioactivity is determined. This permits the quantitation of as little as 0.2 nmoles monosaccharide with an accuracy of 10 to 15%. (Auth)

  18. Validation of a high-performance liquid chromatography/fluorescence detection method for the simultaneous quantification of fifteen polycyclic aromatic hydrocarbons

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Olsen, I L; Holst, E

    1991-01-01

    A high-performance liquid chromatography/fluorescence method using multiple wavelength shift for simultaneous quantification of different PAH compounds was developed. The new method was superior to the methods of DONG and GREENBERG [J. Liquid Chromatogr. 11, 1887-1905 (1988)] and WISE et al...... that no systematic errors, and only small unsystematic errors, could be demonstrated. Furthermore, the method had a good reproducibility and a high sensitivity....

  19. Laboratory analytical methods for the determination of the hydrocarbon status of soils (a review)

    Science.gov (United States)

    Pikovskii, Yu. I.; Korotkov, L. A.; Smirnova, M. A.; Kovach, R. G.

    2017-10-01

    Laboratory analytical methods suitable for the determination of the hydrocarbon status of soils (a specific soil characteristic involving information on the total content and qualitative features of soluble (bitumoid) carbonaceous substances and individual hydrocarbons (polycyclic aromatic hydrocarbons, alkanes, etc.) in bitumoid, as well as the composition and content of hydrocarbon gases) have been considered. Among different physicochemical methods of study, attention is focused on the methods suitable for the wide use. Luminescence-bituminological analysis, low-temperature spectrofluorimetry (Shpolskii spectroscopy), infrared (IR) spectroscopy, gas chromatography, chromatography-mass spectrometry, and some other methods have been characterized, as well as sample preparation features. Advantages and limitations of each of these methods are described; their efficiency, instrumental complexity, analysis duration, and accuracy are assessed.

  20. Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods.

    Science.gov (United States)

    Gambarini, Gianluca; Grande, Nicola Maria; Plotino, Gianluca; Somma, Francesco; Garala, Manish; De Luca, Massimo; Testarelli, Luca

    2008-08-01

    The aim of the present study was to investigate whether cyclic fatigue resistance is increased for nickel-titanium instruments manufactured by using new processes. This was evaluated by comparing instruments produced by using the twisted method (TF; SybronEndo, Orange, CA) and those using the M-wire alloy (GTX; Dentsply Tulsa-Dental Specialties, Tulsa, OK) with instruments produced by a traditional NiTi grinding process (K3, SybronEndo). Tests were performed with a specific cyclic fatigue device that evaluated cycles to failure of rotary instruments inside curved artificial canals. Results indicated that size 06-25 TF instruments showed a significant increase (p 0.05) in the mean number of cycles to failure when compared with size 06-20 GT series X instruments. The new manufacturing process produced nickel-titanium rotary files (TF) significantly more resistant to fatigue than instruments produced with the traditional NiTi grinding process. Instruments produced with M-wire (GTX) were not found to be more resistant to fatigue than instruments produced with the traditional NiTi grinding process.

  1. A reversed-phase high-performance liquid chromatography method for the determination of cotrimoxazole (trimethoprim/ sulphamethoxazole) in children treated for malaria

    DEFF Research Database (Denmark)

    Rønn, A M; Mutabingwa, T K; Kreisby, S

    1999-01-01

    A high-performance liquid chromatography (HPLC) method was developed for the simultaneous analysis of trimethoprim (TMP), sulphamethoxazole (SMX), and acetylsulphamethoxazole (AcSMX) in small amounts of blood. The method involved precipitation with 50 microL trichloracetic acid (1M) to 125 micro...

  2. Phytochemical analysis of ethanolic extract of Dichrostachys Cinerea W and Arn leaves by a thin layer chromatography, high performance thin layer chromatography and column chromatography

    OpenAIRE

    M Vijayalakshmi; K Periyanayagam; K Kavitha; K Akilandeshwari

    2013-01-01

    Background: The leaves of Dichrostachys cinerea are used as laxative, diuretic, painkiller. It is also used in the treatment of gonorrhoea, boils, oedema, gout, veneral diseases and nasopharyngeal affections, etc. Materials and Methods: The Phytochemical investigation of ethanolic extract of D. cinerea leaves were performed by standard chemical tests, thin layer chromatography (TLC) by using various solvent systems, and by high performance liquid chromatography (HPTLC). Two compounds were...

  3. Instrumental neutron activation analysis as a routine method for rock analysis

    International Nuclear Information System (INIS)

    Rosenberg, R.J.

    1977-06-01

    Instrumental neutron activation methods for the analysis of geological samples have been developed. Special emphasis has been laid on the improvement of sensitivity and accuracy in order to maximize tha quality of the analyses. Furthermore, the procedures have been automated as far as possible in order to minimize the cost of the analysis. A short review of the basic literature is given followed by a description of the principles of the method. All aspects concerning the sensitivity are discussed thoroughly in view of the analyst's possibility of influencing them. Experimentally determined detection limits for Na, Al, K, Ca, Sc, Cr, Ti, V, Mn, Fe, Ni, Co, Rb, Zr, Sb, Cs, Ba, La, Ce, Nd, Sm, Eu, Gd, Tb, Dy, Yb, Lu, Hf, Ta, Th and U are given. The errors of the method are discussed followed by actions taken to avoid them. The most significant error was caused by flux deviation, but this was avoided by building a rotating sample holder for rotating the samples during irradiation. A scheme for the INAA of 32 elements is proposed. The method has been automated as far as possible and an automatic γ-spectrometer and a computer program for the automatic calculation of the results are described. Furthermore, a completely automated uranium analyzer based on delayed neutron counting is described. The methods are discussed in view of their applicability to rock analysis. It is stated that the sensitivity varies considerably from element to element and instrumental activation analysis is an excellent method for the analysis of some specific elements like lanthanides, thorium and uranium but less so for many other elements. The accuracy is good varying from 2% to 10% for most elements. Instrumental activation analysis for most elements is rather an expensive method there being, however, a few exceptions. The most important of these is uranium. The analysis of uranium by delayed neutron counting is an inexpensive means for the analysis of large numbers of samples needed for

  4. Development of high performance liquid chromatography method for miconazole analysis in powder sample

    Science.gov (United States)

    Hermawan, D.; Suwandri; Sulaeman, U.; Istiqomah, A.; Aboul-Enein, H. Y.

    2017-02-01

    A simple high performance liquid chromatography (HPLC) method has been developed in this study for the analysis of miconazole, an antifungal drug, in powder sample. The optimized HPLC system using C8 column was achieved using mobile phase composition containing methanol:water (85:15, v/v), a flow rate of 0.8 mL/min, and UV detection at 220 nm. The calibration graph was linear in the range from 10 to 50 mg/L with r 2 of 0.9983. The limit of detection (LOD) and limit of quantitation (LOQ) obtained were 2.24 mg/L and 7.47 mg/L, respectively. The present HPLC method is applicable for the determination of miconazole in the powder sample with a recovery of 101.28 % (RSD = 0.96%, n = 3). The developed HPLC method provides short analysis time, high reproducibility and high sensitivity.

  5. Comparison of extraction chromatography and a procedure based on the molecular recognition method as separation methods in the determination of neptunium and plutonium radionuclides

    International Nuclear Information System (INIS)

    Strisovska, Jana; Galanda, Dusan; Drabova, Veronika; Kuruc, Jozef

    2012-01-01

    The potential of various types of sorbents for separation of radionuclides of plutonium and neptunium were examined. Extraction chromatography and a procedure based on the molecular recognition method were used for the separation. The suitability of the various sorbent types and brands for this purpose was determined. (orig.)

  6. Determination of selected azaarenes in water by bonded-phase extraction and liquid chromatography

    Science.gov (United States)

    Steinheimer, T.R.; Ondrus, M.G.

    1986-01-01

    A method for the rapid and simple quantitative determination of quinoline, isoquinoline, and five selected three-ring azaarenes in water has been developed. The azaarene fraction is separated from its carbon analogues on n-octadecyl packing material by edition with acidified water/acetonitrile. Concentration as great as 1000-fold is achieved readily. Instrumental analysis involves high-speed liquid chromatography on flexible-walled, wide-bore columns with fluorescence and ultraviolet detection at several wavelengths employing filter photometers in series. Method-validation data is provided as azaarene recovery efficiency from fortified samples. Distilled water, river water, contaminated ground water, and secondary-treatment effluent have been tested. Recoveries at part-per-billion levels are nearly quantitative for the three-ring compounds, but they decrease for quinoline and isoquinoline. ?? 1986 American Chemical Society.

  7. Method of decontaminating radioactive-contaminated instruments

    Energy Technology Data Exchange (ETDEWEB)

    Urata, M; Fujii, M; Kitaguchi, H

    1982-03-29

    Purpose: To enable safety processing of liquid wastes by recovering radioactive metal ions remaining in the electrolytes after the decontamination procedure thereby decreasing the radioactivity. Method: In a decontamination tank containing electrolytes consisting of diluted hydrochloric acid and diluted sulfuric acid, are provided a radioactive contaminated instrument connected to an anode and a collector electrode made of stainless steel connected to a cathode respectively. Upon applying electrical current, the portion of the mother material to be decontaminated is polished electrolytically into metal ions and they are deposited as metal on the collection electrode. After completion of the decontamination, an ultrasonic wave generator is operated to strip and remove the oxide films. Thereafter, the anode is replaced with the carbon electrode and electrical current is supplied continuously, whereby the remaining metal ions are deposited and recovered as the metal on the collection electrode.

  8. A validated high performance thin layer chromatography method for determination of yohimbine hydrochloride in pharmaceutical preparations.

    Science.gov (United States)

    Badr, Jihan M

    2013-01-01

    Yohimbine is an indole alkaloid used as a promising therapy for erectile dysfunction. A number of methods were reported for the analysis of yohimbine in the bark or in pharmaceutical preparations. In the present work, a simple and sensitive high performance thin layer chromatographic method is developed for determination of yohimbine (occurring as yohimbine hydrochloride) in pharmaceutical preparations and validated according to International Conference of Harmonization (ICH) guidelines. The method employed thin layer chromatography aluminum sheets precoated with silica gel as the stationary phase and the mobile phase consisted of chloroform:methanol:ammonia (97:3:0.2), which gave compact bands of yohimbine hydrochloride. Linear regression data for the calibration curves of standard yohimbine hydrochloride showed a good linear relationship over a concentration range of 80-1000 ng/spot with respect to the area and correlation coefficient (R(2)) was 0.9965. The method was evaluated regarding accuracy, precision, selectivity, and robustness. Limits of detection and quantitation were recorded as 5 and 40 ng/spot, respectively. The proposed method efficiently separated yohimbine hydrochloride from other components even in complex mixture containing powdered plants. The amount of yohimbine hydrochloride ranged from 2.3 to 5.2 mg/tablet or capsule in preparations containing the pure alkaloid, while it varied from zero (0) to 1.5-1.8 mg/capsule in dietary supplements containing powdered yohimbe bark. We concluded that this method employing high performance thin layer chromatography (HPTLC) in quantitative determination of yohimbine hydrochloride in pharmaceutical preparations is efficient, simple, accurate, and validated.

  9. Chromatography methods and chemometrics for determination of milk fat adulterants

    Science.gov (United States)

    Trbović, D.; Petronijević, R.; Đorđević, V.

    2017-09-01

    Milk and milk-based products are among the leading food categories according to reported cases of food adulteration. Although many authentication problems exist in all areas of the food industry, adequate control methods are required to evaluate the authenticity of milk and milk products in the dairy industry. Moreover, gas chromatography (GC) analysis of triacylglycerols (TAGs) or fatty acid (FA) profiles of milk fat (MF) in combination with multivariate statistical data processing have been used to detect adulterations of milk and dairy products with foreign fats. The adulteration of milk and butter is a major issue for the dairy industry. The major adulterants of MF are vegetable oils (soybean, sunflower, groundnut, coconut, palm and peanut oil) and animal fat (cow tallow and pork lard). Multivariate analysis enables adulterated MF to be distinguished from authentic MF, while taking into account many analytical factors. Various multivariate analysis methods have been proposed to quantitatively detect levels of adulterant non-MFs, with multiple linear regression (MLR) seemingly the most suitable. There is a need for increased use of chemometric data analyses to detect adulterated MF in foods and for their expanded use in routine quality assurance testing.

  10. Development of a high performance liquid chromatography method and a liquid chromatography-tandem mass spectrometry method with pressurized liquid extraction for simultaneous quantification and confirmation of cyromazine, melamine and its metabolites in foods of animal origin

    International Nuclear Information System (INIS)

    Yu Huan; Tao Yanfei; Chen Dongmei; Wang Yulian; Liu Zhaoying; Pan Yuanhu; Huang Lingli; Peng Dapeng; Dai Menghong; Liu Zhenli; Yuan Zonghui

    2010-01-01

    Simple and sensitive methods have been developed for simultaneous detection of cyromazine, melamine and their metabolites (ammeline, ammelide and cyanuric acid) in samples of animal origins. These include a high performance liquid chromatography (HPLC) method and a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method and are useful in regular monitoring and in toxicity studies of these molecules. Representative samples used in this study include muscles and livers of swine, bovine, sheep and chicken, kidneys of swine, bovine and sheep, and milk powder. A new sample preparation procedure with pressurized liquid extraction (PLE) at 1400 psi and 70 deg. C was investigated. Quantification of these five compounds by HPLC was achieved using an APS-2 column with UV detection at 230 nm. Limit of detection (LOD) was at 10 μg kg -1 , and limit of quantification (LOQ) was at 40 μg kg -1 . Recoveries of the five analytes in spiked samples ranged from 72.2% to 115.4% with RSD less than 12%. Confirmatory analysis of the analytes was performed using LC-MS/MS in selected reaction monitoring (SRM) mode. The LOD and LOQ were 5 μg kg -1 and 15 μg kg -1 , respectively. This is the first simultaneous analysis of cyromazine, melamine, ammeline, ammelide and cyanuric acid residues in complex tissue samples using PLE and HPLC. It is expected that these methods will find many practical applications in evaluating the safety of cyromazine, melamine and their metabolites.

  11. Sample displacement chromatography as a method for purification of proteins and peptides from complex mixtures

    Science.gov (United States)

    Gajdosik, Martina Srajer; Clifton, James; Josic, Djuro

    2012-01-01

    Sample displacement chromatography (SDC) in reversed-phase and ion-exchange modes was introduced approximately twenty years ago. This method takes advantage of relative binding affinities of components in a sample mixture. During loading, there is a competition among different sample components for the sorption on the surface of the stationary phase. SDC was first used for the preparative purification of proteins. Later, it was demonstrated that this kind of chromatography can also be performed in ion-exchange, affinity and hydrophobic-interaction mode. It has also been shown that SDC can be performed on monoliths and membrane-based supports in both analytical and preparative scale. Recently, SDC in ion-exchange and hydrophobic interaction mode was also employed successfully for the removal of trace proteins from monoclonal antibody preparations and for the enrichment of low abundance proteins from human plasma. In this review, the principals of SDC are introduced, and the potential for separation of proteins and peptides in micro-analytical, analytical and preparative scale is discussed. PMID:22520159

  12. Study of radiolysis products of natural organic materials by means of gas chromatography

    International Nuclear Information System (INIS)

    Pogocki, D.

    1994-01-01

    Analytical methods based on gas chromatography for identification determination of products arising during food irradiation have been presented. Behind the classics version of the methods one has shown also combined methods being the on-line connection of gas chromatography with mass spectroscopy as well as gas chromatography with liquid chromatography and mass spectroscopy. The applicability as well as weakness and advantages of each version have been discussed on the context of food irradiation. 11 refs, 7 figs

  13. Sugar Determination in Foods with a Radially Compressed High Performance Liquid Chromatography Column.

    Science.gov (United States)

    Ondrus, Martin G.; And Others

    1983-01-01

    Advocates use of Waters Associates Radial Compression Separation System for high performance liquid chromatography. Discusses instrumentation and reagents, outlining procedure for analyzing various foods and discussing typical student data. Points out potential problems due to impurities and pump seal life. Suggests use of ribose as internal…

  14. Development of a method to extract and purify target compounds from medicinal plants in a single step: online hyphenation of expanded bed adsorption chromatography and countercurrent chromatography.

    Science.gov (United States)

    Li, Yang; Wang, Nan; Zhang, Min; Ito, Yoichiro; Zhang, Hongyang; Wang, Yuerong; Guo, Xin; Hu, Ping

    2014-04-01

    Pure compounds extracted and purified from natural sources are crucial to lead discovery and drug screening. This study presents a novel two-dimensional hyphenation of expanded bed adsorption chromatography (EBAC) and high-speed countercurrent chromatography (HSCCC) for extraction and purification of target compounds from medicinal plants in a single step. The EBAC and HSCCC were hyphenated via a six-port injection valve as an interface. Fractionation of ingredients of Salvia miltiorrhiza and Rhizoma coptidis was performed on the hyphenated system to verify its efficacy. Two compounds were harvested from Salvia miltiorrhiza, one was 52.9 mg of salvianolic acid B with an over 95% purity and the other was 2.1 mg of rosmarinic acid with a 74% purity. Another two components were purified from Rhizoma coptidis, one was 4.6 mg of coptisine with a 98% purity and one was 4.1 mg of berberine with a 82% purity. The processing time was nearly 50% that of the multistep method. The results indicate that the present method is a rapid and green way to harvest targets from medicinal plants in a single step.

  15. Instant thin layer chromatography (ITLC) - the most true and convenient method for the determination of radiochemical purity of Tc-99m Labeled radiopharmaceuticals

    International Nuclear Information System (INIS)

    Anwar-Ul-Azim, M.; Ansari, M.I.H.

    2007-01-01

    Full text: Determination of radiochemical purity usually involves paper chromatography method or some column chromatography such as ion exchange or gel filtration technique. In this study, a modified chromatography method with thin-layer support called instant thin Layer chromatography (ITLC) was used for the measurement of radiochemical purity. The aim of the study was to present instant thin layer chromatography-Silica-Gel (ITLC-SG) technique as a fairly rapid , convenient and inexpensive system for the screening of radiochemical impurities of 99mTc-labeled radiopharmaceuticals resulting from physical , chemical and/or radiation decomposition. Materials and Methods: The experiment was carried out at the Institute of Nuclear Medicine and Ultrasound, Dhaka for a period of 10 months from August '05 to May '06. Radiochemical purity of seven types of 99mTc-labeled radiopharmaceuticals, namely 99mTc-DTPA,99mTc- MI I, 99m Tc - HDP, 99m Tc - DMSA, 99m Tc - Tetofosmin, 99mTc-Fyton and 99mTc-ECD were measured by the use of two solvent dual-instant thin layer chromatography systems. Commercially available instant thin layer chromatography plate ( 20cm x20cm) impregnated with silica gel (ITLC-SG: Merck, Germany) was used as a stationary phase for the measurement of radiochemical impurities.Acetone, Ethyl methyl ketone, chloroform and methanol were used to measure the amount of free pertechnetate in the labelled radiopharmaceuticals and 0.9% saline was used in all cases as solvent (Mobile phase) to measure the amount of the hydrolyzed-reduced technetium colloid. Results: The results showed that the measured radiochemical purity of 99mTc-DTPA, 99mTc-MIBI, 99mTc-HDP, 99mTc-DMSA, 99mTc-Tetofosmin, 99mTc-Fyton and 99mTc-ECD were acceptable for all the studied samples except two samples of 99mTc-MIBI, one sample of 99mTc-Fyton and two samples of 99mTc-ECD, where the measured radiochemical purity were not within the acceptable RCP limits of commonly used radiopharmaceuticals (RCP

  16. A Method for Modeling the Virtual Instrument Automatic Test System Based on the Petri Net

    Institute of Scientific and Technical Information of China (English)

    MA Min; CHEN Guang-ju

    2005-01-01

    Virtual instrument is playing the important role in automatic test system. This paper introduces a composition of a virtual instrument automatic test system and takes the VXIbus based a test software platform which is developed by CAT lab of the UESTC as an example. Then a method to model this system based on Petri net is proposed. Through this method, we can analyze the test task scheduling to prevent the deadlock or resources conflict. At last, this paper analyzes the feasibility of this method.

  17. An Automated High Performance Capillary Liquid Chromatography Fourier Transform Ion Cyclotron Resonance Mass Spectrometer for High-Throughput Proteomics

    International Nuclear Information System (INIS)

    Belov, Mikhail E.; Anderson, Gordon A.; Wingerd, Mark A.; Udseth, Harold R.; Tang, Keqi; Prior, David C.; Swanson, Kenneth R.; Buschbach, Michael A.; Strittmatter, Eric F.; Moore, Ronald J.; Smith, Richard D.

    2004-01-01

    We report on a fully automated 9.4 tesla Fourier transform ion resonance cyclotron (FTICR) mass spectrometer coupled to reverse-phase chromatography for high-throughput proteomic studies. Modifications made to the front-end of a commercial FTICR instrument--a dual-ESI-emitter ion source; dual-channel electrodynamic ion funnel; and collisional-cooling, selection and accumulation quadrupoles--significantly improved the sensitivity, dynamic range and mass measurement accuracy of the mass spectrometer. A high-pressure capillary liquid chromatography (LC) system was incorporated with an autosampler that enabled 24 h/day operation. A novel method for accumulating ions in the ICR cell was also developed. Unattended operation of the instrument revealed the exceptional reproducibility (1-5% deviation in elution times for peptides from a bacterial proteome), repeatability (10-20% deviation in detected abundances for peptides from the same aliquot analyzed a few weeks apart) and robustness (high-throughput operation for 5 months without downtime) of the LC/FTICR system. When combined with modulated-ion-energy gated trapping, the internal calibration of FTICR mass spectra decreased dispersion of mass measurement errors for peptide identifications in conjunction with high resolution capillary LC separations to < 5 ppm over a dynamic range for each spectrum of 10 3

  18. Isotope-dilution gas chromatography-mass spectrometry method for the analysis of hydroxyurea.

    Science.gov (United States)

    Garg, Uttam; Scott, David; Frazee, Clint; Kearns, Gregory; Neville, Kathleen

    2015-06-01

    Hydroxyurea is used in the treatment of various malignancies and sickle cell disease. There are limited studies on the pharmacokinetics of hydroxyurea, particularly in pediatric patients. An accurate, precise, and sensitive method is needed to support such studies and to monitor therapeutic adherence. We describe a novel gas chromatography-mass spectrometry (GC-MS) method for the determination of hydroxyurea concentration in plasma using stable labeled hydroxyurea C N2 as an internal standard. The method involved an organic extraction followed by the preparation of trimethylsilyl (TMS) derivatives of hydroxyurea for GC-MS selected ion-monitoring analysis. The following mass-to-charge (m/z) ratio ions for silated hydroxyurea and hydroxyurea C N2 were monitored: hydroxyurea-quantitative ion 277, qualifier ions 292 and 249; hydroxyurea C N2-quantitative ion 280, qualifier ion 295. This method was evaluated for reportable range, accuracy, within-run and between-run imprecisions, and limits of quantification. The reportable range for the method was 0.1-100 mcg/mL. All results were accurate within an allowable error of 15%. Within-run and between-run imprecisions were hydroxyurea described here is accurate, sensitive, precise, and robust. Its characteristics make the method suitable for supporting pharmacokinetic studies and/or clinical therapeutic monitoring.

  19. Method of decontaminating radioactive-contaminated instruments

    International Nuclear Information System (INIS)

    Urata, Megumu; Fujii, Masaaki; Kitaguchi, Hiroshi.

    1982-01-01

    Purpose: To enable safety processing of liquid wastes by recovering radioactive metal ions remaining in the electrolytes after the decontamination procedure thereby decreasing the radioactivity. Method: In a decontamination tank containing electrolytes consisting of diluted hydrochloric acid and diluted sulfuric acid, are provided a radioactive contaminated instrument connected to an anode and a collector electrode made of stainless steel connected to a cathode respectively. Upon applying electrical current, the portion of the mother material to be decontaminated is polished electrolytically into metal ions and they are deposited as metal on the collection electrode. After completion of the decontamination, an ultrasonic wave generator is operated to strip and remove the oxide films. Thereafter, the anode is replaced with the carbon electrode and electrical current is supplied continuously, whereby the remaining metal ions are deposited and recovered as the metal on the collection electrode. (Yoshino, Y.)

  20. Supercritical fluid chromatography for GMP analysis in support of pharmaceutical development and manufacturing activities.

    Science.gov (United States)

    Hicks, Michael B; Regalado, Erik L; Tan, Feng; Gong, Xiaoyi; Welch, Christopher J

    2016-01-05

    Supercritical fluid chromatography (SFC) has long been a preferred method for enantiopurity analysis in support of pharmaceutical discovery and development, but implementation of the technique in regulated GMP laboratories has been somewhat slow, owing to limitations in instrument sensitivity, reproducibility, accuracy and robustness. In recent years, commercialization of next generation analytical SFC instrumentation has addressed previous shortcomings, making the technique better suited for GMP analysis. In this study we investigate the use of modern SFC for enantiopurity analysis of several pharmaceutical intermediates and compare the results with the conventional HPLC approaches historically used for analysis in a GMP setting. The findings clearly illustrate that modern SFC now exhibits improved precision, reproducibility, accuracy and robustness; also providing superior resolution and peak capacity compared to HPLC. Based on these findings, the use of modern chiral SFC is recommended for GMP studies of stereochemistry in pharmaceutical development and manufacturing. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Novel method for measurement of glutathione kinetics in neonates using liquid chromatography coupled to isotope ratio mass spectrometry

    NARCIS (Netherlands)

    Schierbeek, Henk; te Braake, Frans; Godin, Jean-Philippe; Fay, Laurent-Bernard; van Goudoever, Johannes B.

    2007-01-01

    A novel analytical method using liquid chromatography coupled to isotope ratio mass spectrometry (LC/IRMS) was developed for measuring the fractional synthesis rate (FSR) of glutathione (GSH) in neonates after infusion of [1-(13)C]-glycine as a tracer. After transformation of GSH into GSSG, its

  2. Method of case hardening depth testing by using multifunctional ultrasonic testing instrument

    International Nuclear Information System (INIS)

    Salchak, Y A; Sednev, D A; Ardashkin, I B; Kroening, M

    2015-01-01

    The paper describes usability of ultrasonic case hardening depth control applying standard instrument of ultrasonic inspections. The ultrasonic method of measuring the depth of the hardened layer is proposed. Experimental series within the specified and multifunctional ultrasonic equipment are performed. The obtained results are compared with the results of a referent method of analysis. (paper)

  3. Recent applications of gas chromatography with high-resolution mass spectrometry.

    Science.gov (United States)

    Špánik, Ivan; Machyňáková, Andrea

    2018-01-01

    Gas chromatography coupled to high-resolution mass spectrometry is a powerful analytical method that combines excellent separation power of gas chromatography with improved identification based on an accurate mass measurement. These features designate gas chromatography with high-resolution mass spectrometry as the first choice for identification and structure elucidation of unknown volatile and semi-volatile organic compounds. Gas chromatography with high-resolution mass spectrometry quantitative analyses was previously focused on the determination of dioxins and related compounds using magnetic sector type analyzers, a standing requirement of many international standards. The introduction of a quadrupole high-resolution time-of-flight mass analyzer broadened interest in this method and novel applications were developed, especially for multi-target screening purposes. This review is focused on the development and the most interesting applications of gas chromatography coupled to high-resolution mass spectrometry towards analysis of environmental matrices, biological fluids, and food safety since 2010. The main attention is paid to various approaches and applications of gas chromatography coupled to high-resolution mass spectrometry for non-target screening to identify contaminants and to characterize the chemical composition of environmental, food, and biological samples. The most interesting quantitative applications, where a significant contribution of gas chromatography with high-resolution mass spectrometry over the currently used methods is expected, will be discussed as well. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Methods in endogenous steroid profiling - A comparison of gas chromatography mass spectrometry (GC-MS) with supercritical fluid chromatography tandem mass spectrometry (SFC-MS/MS).

    Science.gov (United States)

    Teubel, Juliane; Wüst, Bernhard; Schipke, Carola G; Peters, Oliver; Parr, Maria Kristina

    2018-06-15

    In various fields of endocrinology, the determination of steroid hormones synthesised by the human body plays an important role. Research on central neurosteroids has been intensified within the last years, as they are discussed as biomarkers for various cognitive disorders. Their concentrations in cerebrospinal fluid (CSF) are considered to be regulated independently from peripheral fluids. For that reason, the challenging matrix CSF becomes a very interesting specimen for analysis. Concentrations are expected to be very low and available amount of CSF is limited. Thus, a comprehensive method for very sensitive quantification of a set of analytes as large as possible in one analytical aliquot is desired. However, high structural similarities of the selected panel of 51 steroids and steroid sulfates, including numerous isomers, challenges achievement of chromatographic selectivity. Since decades the analysis of endogenous steroids in various body fluids is mainly performed by gas chromatography (GC) coupled to (tandem) mass spectrometry (MS(/MS)). Due to the structure of the steroids of interest, derivatisation is performed to meet the analytical requirements for GC-MS(/MS). Most of the laboratories use a two-step derivatisation in multi-analyte assays that was already published in the 1980s. However, for some steroids this elaborate procedure yields multiple isomeric derivatives. Thus, some laboratories utilize (ultra) high performance liquid chromatography ((U)HPLC)-MS/MS as alternative but, even UHPLC is not able to separate some of the isomeric pairs. Supercritical fluid chromatography (SFC) as an orthogonal separation technique to GC and (U)HPLC may help to overcome these issues. Within this project the two most promising methods for endogenous steroid profiling were investigated and compared: the "gold standard" GC-MS and the orthogonal separation technique SFC-MS/MS. Different derivatisation procedures for gas chromatographic detection were explored and the

  5. High-performance liquid chromatography ultraviolet-photodiode array detection method for aflatoxin B1 in cattle feed supplements

    Science.gov (United States)

    Mochamad, Lazuardi; Hermanto, Bambang

    2017-01-01

    Aim: The objective of the current study is to determine the concentration of aflatoxin B1 using high-performance liquid chromatography (HPLC) with a photodiode array (PDA) detector. Materials and Methods: Aflatoxin B1 certified reference grade from Trilogy Analytical Laboratory dissolved acetonitrile (ACN) at 10 µg/mL was using standard assessment. HPLC instruments such as ultraviolet-PDA detector used a Shimadzu LC-6AD pump with DGU-20A5 degasser, communication module-20A, and PDA detector SPD-M20A with FRC-10A fraction collector. The HPLC was set isocratic method at 354 nm with a reverse-phase ODS C18 column (LiChrospher® 100 RP-18; diameter, 5 µm) under a 20°C controlled column chamber. Rheodyne® sample loops were performed in 20 µL capacities. The mobile phase was performed at fraction 63:26:11 H2O: methanol:ACN at pH 6.8. A total of 1 kg of feed contained 10% bread crumbs and 30% concentrated, 40% forage, and 20% soybean dregs were using commercials samples. Samples were extracted by ACN and separated with solid phase extraction ODS 1 mL than elution with mobile phase to collect at drying samples performed. The samples were ready to use after added 1 mL mobile phase than injected into the system of HPLC. Results: We found that the retention time of aflatoxin B1 was approximately 10.858 min. Linearity of 0.01-0.08 µg/mL aflatoxin B1 dissolved in mobile phase was obtained at R2=0.9. These results demonstrate that these methods can be used to analyze aflatoxin B1 and gain 89-99% recovery. The limit of detection of this assay was obtained at 3.5 × 10−6 µg/mL. Conclusion: This method was easy to apply and suitable to analyzing at small concentrations of aflatoxin B1 in formulated product of feed cattle. PMID:28919686

  6. High-performance liquid chromatography analysis methods developed for quantifying enzymatic esterification of flavonoids in ionic liquids

    DEFF Research Database (Denmark)

    Lue, Bena-Marie; Guo, Zheng; Xu, X.B.

    2008-01-01

    Methods using reversed-phase high-performance liquid chromatography (RP-HPLC) with ELSD were investigated to quantify enzymatic reactions of flavonoids with fatty acids in the presence of diverse room temperature ionic liquids (RTILs). A buffered salt (preferably triethylamine-acetate) was found...... essential for separation of flavonoids from strongly polar RTILs, whereby RTILs were generally visible as two major peaks identified based on an ion-pairing/exchanging hypothesis. C8 and C12 stationary phases were optimal while mobile phase pH (3-7) had only a minor influence on separation. The method...

  7. Development of a new screening method for the detection of antibiotic residues in muscle tissues using liquid chromatography and high resolution mass spectrometry with a LC-LTQ-Orbitrap instrument.

    Science.gov (United States)

    Hurtaud-Pessel, D; Jagadeshwar-Reddy, T; Verdon, E

    2011-10-01

    A liquid chromatography-high resolution mass spectrometry (LC-HRMS) method was developed for screening meat for a wide range of antibiotics used in veterinary medicine. Full-scan mode under high resolution mass spectral conditions using an LTQ-Orbitrap mass spectrometer with resolving power 60,000 full width at half maximum (FWHM) was applied for analysis of the samples. Samples were prepared using two extraction protocols prior to LC-HRMS analysis. The scope of the method focuses on screening the following main families of antibacterial veterinary drugs: penicillins, cephalosporins, sulfonamides, macrolides, tetracyclines, aminoglucosides and quinolones. Compounds were successfully identified in spiked samples from their accurate mass and LC retention times from the acquired full-scan chromatogram. Automated data processing using ToxId software allowed rapid treatment of the data. Analyses of muscle tissues from real samples collected from antibiotic-treated animals was carried out using the above methodology and antibiotic residues were identified unambiguously. Further analysis of the data for real samples allowed the identification of the targeted antibiotic residues but also non-targeted compounds, such as some of their metabolites.

  8. Field astrobiology research instruments and methods in moon-mars analogue site.

    NARCIS (Netherlands)

    Foing, B.H.; Stoker, C.; Zavaleta, J.; Ehrenfreund, P.; Sarrazin, P.; Blake, D.; Page, J.; Pletser, V.; Hendrikse, J.; Oliveira Lebre Direito, M.S.; Kotler, M.; Martins, Z.; Orzechowska, G.; Thiel, C.S.; Clarke, J.; Gross, J.; Wendt, L.; Borst, A.; Peters, S.; Wilhelm, M.-B.; Davies, G.R.; EuroGeoMars 2009 Team, ILEWG

    2011-01-01

    We describe the field demonstration of astrobiology instruments and research methods conducted in and from the Mars Desert Research Station (MDRS) in Utah during the EuroGeoMars campaign 2009 coordinated by ILEWG, ESA/ESTEC and NASA Ames, with the contribution of academic partners. We discuss the

  9. Reference Proteome Extracts for Mass Spec Instrument Performance Validation and Method Development

    Science.gov (United States)

    Rosenblatt, Mike; Urh, Marjeta; Saveliev, Sergei

    2014-01-01

    Biological samples of high complexity are required to test protein mass spec sample preparation procedures and validate mass spec instrument performance. Total cell protein extracts provide the needed sample complexity. However, to be compatible with mass spec applications, such extracts should meet a number of design requirements: compatibility with LC/MS (free of detergents, etc.)high protein integrity (minimal level of protein degradation and non-biological PTMs)compatibility with common sample preparation methods such as proteolysis, PTM enrichment and mass-tag labelingLot-to-lot reproducibility Here we describe total protein extracts from yeast and human cells that meet the above criteria. Two extract formats have been developed: Intact protein extracts with primary use for sample preparation method development and optimizationPre-digested extracts (peptides) with primary use for instrument validation and performance monitoring

  10. METHOD 332.0: DETERMINATION OF PERCHLORATE IN DRINKING WATER BY ION CHROMATOGRAPHY WITH SUPPRESSED CONDUCTIVITY AND ELECTROSPRAY IONIZATION MASS SPECTROMETRY

    Science.gov (United States)

    This method is applicable to the identification and quantitation of perchlorate in raw and finished drinking waters. The approach used is ion chromatography with suppressed conductivity and electrospray ionization mass spectrometry (IC-ESI/MS)

  11. The influence of different referencing methods on the accuracy of δ(13) C value measurement of ethanol fuel by gas chromatography/combustion/isotope ratio mass spectrometry.

    Science.gov (United States)

    Neves, Laura A; Rodrigues, Janaína M; Daroda, Romeu J; Silva, Paulo R M; Ferreira, Alexandre A; Aranda, Donato A G; Eberlin, Marcos N; Fasciotti, Maíra

    2015-11-15

    Brazil is the largest producer of sugar cane bioethanol in the world. Isotope ratio mass spectrometry (IRMS) is the technique of choice to certify the origin/raw materials for ethanol production, but the lack of certified reference materials (CRMs) for accurate measurements of δ(13) C values traceable to Vienna Pee Dee Belemnite (VPDB), the international zero point for (13) C/(12) C measurements, certified and compatible with gas chromatography (GC)/IRMS instruments may compromise the accuracy of δ(13) C determinations. We evaluated the influence of methods for the calibration and normalization of raw δ(13) C values of ethanol samples. Samples were analyzed by GC/C/IRMS using two different GC columns. Different substances were used as isotopic standards for the working gas calibration. The δ(13) C values obtained with the three methods of normalization were statistically compared with those obtained with elemental analyzer (EA)/IRMS, since the δ(13) C results obtained using EA are traceable to VPDB via the NBS 22 reference material. It was observed that both the isotopic reference material for CO2 calibration and the GC column have a major effect on the δ(13) C measurements, leading to a bias of almost 2-3 ‰ in the δ(13) C values. All three methods of normalization were equivalent in performance, enabling an improvement in the GC/C/IRMS accuracy, compared with the EA/IRMS reference values for the samples. All the methods of CO2 calibration, chromatography and normalization presented in this work demonstrated several sources of traceability and accuracy loss for the determination of δ(13) C values in ethanol fuel samples by GC/C/IRMS. This work has also shown the importance of using proper CRMs traceable to VPBD that should be compatible and certified using GC/C/IRMS, ideally in a wide range of δ(13) C values. This is important not only for bioethanol fuel samples, but also for many analytes commonly analyzed by IRMS. Copyright © 2015 John Wiley & Sons

  12. Microcystin Detection Characteristics of Fluorescence Immunochromatography and High Performance Liquid Chromatography

    International Nuclear Information System (INIS)

    Pyo, Dong Jin; Park, Geun Young; Choi, Jong Chon; Oh, Chang Suk

    2005-01-01

    Different detection characteristics of fluorescence immunochromatography method and high performance liquid chromatography (HPLC) method for the analysis of cyanobacterial toxins were studied. In particular, low and high limits of detection, detection time and reproducibility and detectable microcystin species were compared when fluorescence immunochromatography method and high performance liquid chromatography method were applied for the detection of microcystin (MC), a cyclic peptide toxin of the freshwater cyanobacterium Microcystis aeruginosa. A Fluorescence immunochromatography assay system has the unique advantages of short detection time and low detection limit, and high performance liquid chromatography detection method has the strong advantage of individual quantifications of several species of microcystins

  13. Educational Program Improvement in Chemistry Through the Acquisition of GC/MS And FT-NMR Instruments

    National Research Council Canada - National Science Library

    Anderson, Gloria

    1997-01-01

    ...), Department of Defense. The purpose of this grant was to enable the department to acquire instrumentation necessary for incorporating the theory and practice of Gas Chromatography/Mass Spectrometry (GC/MS...

  14. Systematic comparison of static and dynamic headspace sampling techniques for gas chromatography.

    Science.gov (United States)

    Kremser, Andreas; Jochmann, Maik A; Schmidt, Torsten C

    2016-09-01

    Six automated, headspace-based sample preparation techniques were used to extract volatile analytes from water with the goal of establishing a systematic comparison between commonly available instrumental alternatives. To that end, these six techniques were used in conjunction with the same gas chromatography instrument for analysis of a common set of volatile organic carbon (VOC) analytes. The methods were thereby divided into three classes: static sampling (by syringe or loop), static enrichment (SPME and PAL SPME Arrow), and dynamic enrichment (ITEX and trap sampling). For PAL SPME Arrow, different sorption phase materials were also included in the evaluation. To enable an effective comparison, method detection limits (MDLs), relative standard deviations (RSDs), and extraction yields were determined and are discussed for all techniques. While static sampling techniques exhibited sufficient extraction yields (approx. 10-20 %) to be reliably used down to approx. 100 ng L(-1), enrichment techniques displayed extraction yields of up to 80 %, resulting in MDLs down to the picogram per liter range. RSDs for all techniques were below 27 %. The choice on one of the different instrumental modes of operation (aforementioned classes) was thereby the most influential parameter in terms of extraction yields and MDLs. Individual methods inside each class showed smaller deviations, and the least influences were observed when evaluating different sorption phase materials for the individual enrichment techniques. The option of selecting specialized sorption phase materials may, however, be more important when analyzing analytes with different properties such as high polarity or the capability of specific molecular interactions. Graphical Abstract PAL SPME Arrow during the extraction of volatile analytes from the headspace of an aqueous sample.

  15. Advances in chromatography of the rare earth elements (review)

    International Nuclear Information System (INIS)

    Oguma, Koichi; Kuroda, Rokuro; Shimizu, Tsuneo.

    1995-01-01

    A review is presented which covers liquid chromatography, gas chromatography, and related techniques. This article intends to describe the chromatographic methods playing an important role in the separation of the rare earth elements. Special attention is paid to the usefulness of various types of liquid chromatography which enable the complete mutual separation of the rare earth elements. Applications are also discussed. (author) 161 refs

  16. Improved method for the determination of the cortisol production rate using high-performance liquid chromatography and liquid scintillation counting

    NARCIS (Netherlands)

    van Ingen, H. E.; Endert, E.

    1988-01-01

    Two new methods for the determination of the cortisol production rate using reversed-phase high-performance liquid chromatography are described. One uses ultraviolet detection at 205 nm, the other on-line post-column derivatization with benzamidine, followed by fluorimetric detection. The specific

  17. A method for retrieving endodontic or atypical nonendodontic separated instruments from the root canal: a report of two cases.

    Science.gov (United States)

    Monteiro, Jardel Camilo do Carmo; Kuga, Milton Carlos; Dantas, Andrea Abi Rached; Jordão-Basso, Keren Cristina Fagundes; Keine, Katia Cristina; Ruchaya, Prashant Jay; Faria, Gisele; Leonardo, Renato de Toledo

    2014-11-01

    This clinical report presents a new method for retrieving separated instruments from the root canal with minimally invasive procedures. The presence of separated instrument in root canal may interfere in the endodontic treatment prognosis. There are several recommended methods to retrieve separated instruments, but some are difficult in clinically practice. This study describes two cases of separated instrument removal from the root canal using a stainless-steel prepared needle associated with a K-file. Case 1 presented a fractured gutta-percha condenser within the mandibular second premolar, it was separated during incorrect intracanal medication calcium hydroxide placement. Case 2 had a fractured sewing needle within the upper central incisor that the patient used to remove food debris from the root canal. After cervical preparation, the fractured instruments were fitted inside a prepared needle and then an endodontic instrument (#25 K-file) was adapted with clockwise turning motion between the needle inner wall and the fragment. The endodontic or atypical nonendodontic separated instrument may be easily pull on of the root canal using a single and low cost device. The methods for retrieving separated instruments from root canal are difficult and destructive procedures. The present case describes a simple method to solve this problem.

  18. Schinus terebinthifolius scale-up countercurrent chromatography (Part I): High performance countercurrent chromatography fractionation of triterpene acids with off-line detection using atmospheric pressure chemical ionization mass spectrometry.

    Science.gov (United States)

    Vieira, Mariana Neves; Costa, Fernanda das Neves; Leitão, Gilda Guimarães; Garrard, Ian; Hewitson, Peter; Ignatova, Svetlana; Winterhalter, Peter; Jerz, Gerold

    2015-04-10

    'Countercurrent chromatography' (CCC) is an ideal technique for the recovery, purification and isolation of bioactive natural products, due to the liquid nature of the stationary phase, process predictability and the possibility of scale-up from analytical to preparative scale. In this work, a method developed for the fractionation of Schinus terebinthifolius Raddi berries dichloromethane extract was thoroughly optimized to achieve maximal throughput with minimal solvent and time consumption per gram of processed crude extract, using analytical, semi-preparative and preparative 'high performance countercurrent chromatography' (HPCCC) instruments. The method using the biphasic solvent system composed of n-heptane-ethyl acetate-methanol-water (6:1:6:1, v/v/v/v) was volumetrically scaled up to increase sample throughput up to 120 times, while maintaining separation efficiency and time. As a fast and specific detection alternative, the fractions collected from the CCC-separations were injected to an 'atmospheric pressure chemical ionization mass-spectrometer' (APCI-MS/MS) and reconstituted molecular weight MS-chromatograms of the APCI-ionizable compounds from S. terebinthifolius were obtained. This procedure led to the direct isolation of tirucallane type triterpenes such as masticadienonic and 3β-masticadienolic acids. Also oleanonic and moronic acids have been identified for the first time in the species. In summary, this approach can be used for other CCC scale-up processes, enabling MS-target-guided isolation procedures. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Unexpected but Most Welcome: Mixed Methods for the Validation and Revision of the Participatory Evaluation Measurement Instrument

    Science.gov (United States)

    Daigneault, Pierre-Marc; Jacob, Steve

    2014-01-01

    Although combining methods is nothing new, more contributions about why and how to mix methods for validation purposes are needed. This article presents a case of validating the inferences drawn from the Participatory Evaluation Measurement Instrument, an instrument that purports to measure stakeholder participation in evaluation. Although the…

  20. Application of gas chromatography/flame ionization detector-based metabolite fingerprinting for authentication of Asian palm civet coffee (Kopi Luwak).

    Science.gov (United States)

    Jumhawan, Udi; Putri, Sastia Prama; Yusianto; Bamba, Takeshi; Fukusaki, Eiichiro

    2015-11-01

    Development of authenticity screening for Asian palm civet coffee, the world-renowned priciest coffee, was previously reported using metabolite profiling through gas chromatography/mass spectrometry (GC/MS). However, a major drawback of this approach is the high cost of the instrument and maintenance. Therefore, an alternative method is needed for quality and authenticity evaluation of civet coffee. A rapid, reliable and cost-effective analysis employing a universal detector, GC coupled with flame ionization detector (FID), and metabolite fingerprinting has been established for discrimination analysis of 37 commercial and non-commercial coffee beans extracts. gas chromatography/flame ionization detector (GC/FID) provided higher sensitivity over a similar range of detected compounds than GC/MS. In combination with multivariate analysis, GC/FID could successfully reproduce quality prediction from GC/MS for differentiation of commercial civet coffee, regular coffee and coffee blend with 50 wt % civet coffee content without prior metabolite details. Our study demonstrated that GC/FID-based metabolite fingerprinting can be effectively actualized as an alternative method for coffee authenticity screening in industries. Copyright © 2015. Published by Elsevier B.V.

  1. Design and operation of dust measuring instrumentation based on the beta-radiation method

    International Nuclear Information System (INIS)

    Lilienfeld, P.

    1975-01-01

    The theory, instrument design aspects and applications of beta-radiation attenuation for the measurement of the mass concentration of airborne particulates are reviewed. Applicable methods of particle collection, beta sensing configurations, source ( 63 Ni, 14 C, 147 Pr, 85 Kr) and detector design criteria, electronic signal processing, digital control and instrument programming techniques are treated. Advantages, limitations and error sources of beta-attenuation instrumentation are analyzed. Applications to industrial dust measurements, source testing, ambient monitoring, and particle size analysis are the major areas of practical utilization of this technique, and its inherent capability for automated and unattended operation provides compatibility with process control synchronization and alarm, telemetry, and incorporation into pollution monitoring network sensing stations. (orig.) [de

  2. Confirmatory analysis method for zeranol, its metabolites and related mycotoxins in urine by liquid chromatography-negative ion electrospray tandem mass spectrometry

    International Nuclear Information System (INIS)

    Bennekom, E.O. van; Brouwer, L.; Laurant, E.H.M.; Hooijerink, H.; Nielen, M.W.F.

    2002-01-01

    The determination of the banned anabolic substance zeranol and the metabolites taleranol and zearalanone in bovine urine is complicated by the occurrence of the structurally-related mycotoxin zearalenone and the corresponding α- and β-zearalenol metabolites which possess similar estrogenic properties. A liquid chromatography-negative ion electrospray tandem mass spectrometric method is presented for the confirmatory analysis of all six resorcylic acid lactones ('zeranols') in urine samples using deuterium-labelled internal standards. The method was validated as a confirmatory method for bovine urine samples according to new draft EU guidelines and showed good precision and linearity, and CCα and CCβ values of 0.02-0.30 and -1 , respectively. The applicability was demonstrated by comparing the results of an incurred sample with previous results on the same sample obtained by gas chromatography high resolution mass spectrometry. Preliminary data show that following a simple matrix solid phase dispersion clean-up, liver samples from poultry will be amenable to this method as well

  3. Hydrophilic Interaction Liquid Chromatography/Mass Spectrometry: An Attractive and Prospective Method for the Quantitative Bioanalysis in Drug Metabolism.

    Science.gov (United States)

    Li, Zheng; Han, Jie; Sun, Shi-an; Chen, Kai; Tang, Dao-quan

    2016-01-01

    During the development, dosage optimization and safety evaluation of a drug, rapid and precise monitoring of administered drug and/or its metabolites in biological samples including blood, plasma, serum, tissues and saliva are vital. As drug biotransformation produces more hydrophilic metabolites for the enhancement of drug elimination, which is often a challenge for traditional reversed-phase liquid chromatography (RPLC) separation. Because hydrophilic interaction liquid chromatography (HILIC) is capable of retaining polar compounds and readily compatible with mass spectrometry (MS), HILIC has been used as a complementary separation technique to RPLC for analysis of polar metabolites, especially polar drugs and their metabolites. This review covers core aspects of HILIC-MS/MS method and overall profile of its application in analysis of drug and/or its metabolites. The emphasis of this paper has been placed on the applications of HILIC-MS/MS method in quantitative bioanalysis of drugs alone or along with their metabolites in drug metabolism studies in recent years. As a fundamental and critical step of bioanalytical method, conventional sample preparation techniques of biological matrices for the HILIC-MS/MS analysis of drugs and/or their metabolites are also briefly featured.

  4. A new method for the radiation representation of musical instruments in auralizations

    DEFF Research Database (Denmark)

    Rindel, Jens Holger; Otondo, Felipe

    2005-01-01

    A new method for the representation of sound sources that vary their directivity in time in auralizations is introduced. A recording method with multi-channel anechoic recordings is proposed in connection with the use of a multiple virtual source reproduction system in auralizations. Listening ex...... to be significant. Further applications of the method are considered for ensembles within room auralizations as well as in the field of studio recording techniques for large instruments....

  5. Characterisation of organic compounds in aerosol particles from a finnish forest by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Shimmo, Masahiko; Jaentti, Jaana; Hartonen, Kari; Hyoetylaeinen, Tuulia; Riekkola, Marja-Liisa [Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, 00014, Helsinki (Finland); Aalto, Pasi; Kulmala, Markku [Division of Atmospheric Sciences, Department of Physical Sciences, University of Helsinki, P.O. Box 64, 00014, Helsinki (Finland)

    2004-04-01

    During the European Union project Quantification of Aerosol Nucleation in the European Boundary Layer (QUEST), which began in spring 2003, atmospheric aerosol particles were collected in a Finnish Scots pine forest using a high-volume sampler. The organic compounds in the filter samples were then analysed by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry (SFE-LC-GC-MS). The sample was first extracted by SFE. During LC the extracts were fractionated into three fractions according to polarity. The final separation was carried out by GC-MS. A fraction volume as high as 840 {mu}L was transferred to the GC, using the partial concurrent eluent evaporation technique. The same instrumentation, with an in-situ SFE derivatisation method, was used to analyse organic acids. Major compounds such as n-alkanes and PAH were analysed quantitatively. Their concentrations were lower than those usually observed in urban areas or in other forest areas in Europe. The wind direction was one of the most important factors affecting changes in the daily concentrations of these compounds. Scots pine needles were analysed with the same system to obtain reference data for identification of biogenic compounds in aerosol particles. Other organic compounds found in this study included hopanes, steranes, n-alkanals, n-alkan-2-ones, oxy-PAH, and alkyl-PAH; some biogenic products, including oxidation products of monoterpenes, were also identified. (orig.)

  6. Evaluation of two disinfection/sterilization methods on silicon rubber-based composite finishing instruments.

    Science.gov (United States)

    Lacerda, Vánia A; Pereira, Leandro O; Hirata JUNIOR, Raphael; Perez, Cesar R

    2015-12-01

    To evaluate the effectiveness of disinfection/sterilization methods and their effects on polishing capacity, micomorphology, and composition of two different composite fiishing and polishing instruments. Two brands of finishing and polishing instruments (Jiffy and Optimize), were analyzed. For the antimicrobial test, 60 points (30 of each brand) were used for polishing composite restorations and submitted to three different groups of disinfection/sterilization methods: none (control), autoclaving, and immersion in peracetic acid for 60 minutes. The in vitro tests were performed to evaluate the polishing performance on resin composite disks (Amelogen) using a 3D scanner (Talyscan) and to evaluate the effects on the points' surface composition (XRF) and micromorphology (MEV) after completing a polishing and sterilizing routine five times. Both sterilization/disinfection methods were efficient against oral cultivable organisms and no deleterious modification was observed to point surface.

  7. Gel chromatography of sup(99m)Tc-labelled compounds

    International Nuclear Information System (INIS)

    Vilcek, S.; Machan, V.; Kalincak, M.

    1976-01-01

    The present state of gel chromatography of sup(99m)Tc-labelled compounds is reviewed. Examples are given of gel chromatography for preparing labelled compounds and for quality control analysis and the development of new types of sup(99m)Tc-labelled compounds. The factors which influence the gel chromatography of these compounds are discussed, i.e., the nature of the elution agent, the duration of the contact of the gel and the preparation the gel type, the nature of the labelled compound. The GCS method (gel chromatography scanning) is briefly described. The advantages of gel chromatography as compared with other chromatographic techniques for sup(99m)Tc-labelled compounds are summarized. (author)

  8. A Simple Thin Layer Chromatography Method for Separation of Selected Natural Steroid Hormones

    International Nuclear Information System (INIS)

    Nowakowska, J.; Rudnicka-Litka, K.; Ciura, K.; Pikul, P.; Piotrowicz, J.

    2015-01-01

    Chromatographic properties of seven steroids: estrogens (β-estradiol and estrone), androgens (testosterone, methyltestosterone, trans-androsterone), progesterone and cholesterol have been studied by planar chromatography with usage of High Performance Thin Layer Chromatography (HPTLC) and Thin Layer Chromatography (TLC) plates. Normal, reversed and cyano-bonded silica stationary phases were tested with five binary mobile phases (acetonitrile-water, acetonitrile-DMSO, acetonitrile-methanol, acetone-petroleum ether, acetone-water) in which the concentration of organic modifier varied from 0 to 100 % (v/v). This study reports the optimization of steroid hormones separation. Principal Component Analysis (PCA) based on calculated molecular descriptors quantitatively differentiating solutes was performed in order to investigate the similarity and dissimilarity between tested compounds. The separation abilities of mobile and stationary phases were compared based on separation factor α. Chromatographic retention data and possible retention mechanisms also were discussed. (author)

  9. High-performance liquid chromatography method with radiochemical detection for measurement of nitric oxide synthase, arginase, and arginine decarboxylase activities

    DEFF Research Database (Denmark)

    Volke, A; Wegener, Gregers; Vasar, E

    2006-01-01

    regulate NOS activity. We aimed to develop a HPLC-based method to measure simultaneously the products of these three enzymes. Traditionally, the separation of amino acids and related compounds with HPLC has been carried out with precolumn derivatization and reverse phase chromatography. We describe here...

  10. Gas Chromatography-Mass Spectroscopic (GC-MS) Analysis of n ...

    African Journals Online (AJOL)

    tuber-regium (synonym Pleurotus tuber regium) using gas chromatography-mass spectroscopic (GC-. MS) techniques. Methods: The n-hexane extract of the sclerotia ... Soxhlet extraction and analysed using gas chromatography-mass spectroscopic (MS) techniques. ..... Phytochemical composition of Pleurotus tuber regium.

  11. Assessing learning outcomes in middle-division classical mechanics: The Colorado Classical Mechanics and Math Methods Instrument

    Science.gov (United States)

    Caballero, Marcos D.; Doughty, Leanne; Turnbull, Anna M.; Pepper, Rachel E.; Pollock, Steven J.

    2017-06-01

    Reliable and validated assessments of introductory physics have been instrumental in driving curricular and pedagogical reforms that lead to improved student learning. As part of an effort to systematically improve our sophomore-level classical mechanics and math methods course (CM 1) at CU Boulder, we have developed a tool to assess student learning of CM 1 concepts in the upper division. The Colorado Classical Mechanics and Math Methods Instrument (CCMI) builds on faculty consensus learning goals and systematic observations of student difficulties. The result is a 9-question open-ended post test that probes student learning in the first half of a two-semester classical mechanics and math methods sequence. In this paper, we describe the design and development of this instrument, its validation, and measurements made in classes at CU Boulder and elsewhere.

  12. COMPUTER-ASSISTED HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY METHOD DEVELOPMENT WITH APPLICATIONS TO THE ISOLATION AND ANALYSIS OF PHYTOPLANKTON PIGMENTS. (R826944)

    Science.gov (United States)

    We used chromatography modeling software to assist in HPLC method development, with the goalof enhancing separations through the exclusive use of gradient time and column temperature. Wesurveyed nine stationary phases for their utility in pigment purification and natur...

  13. Supercritical fluid extraction-gas chromatography of volatile organic compounds (VOC) from Tenax devices. Final report, November 1985-September 1986

    International Nuclear Information System (INIS)

    Wright, B.W.; Kopriva, A.J.; Smith, R.D.

    1987-11-01

    This report describes the development and evaluation of on-line supercritical-fluid extraction - gas-chromatography instrumentation and methodology for the analysis of volatile organic compounds (VOC) from adsorbent sampling devices. Supercritical fluid extraction offers potential advantages for the removal and transport of organic components from adsorbent matrices including rapid and efficient extraction at mild temperatures. Extraction at mild temperatures eliminates potential problems such as analyte decomposition that can be encountered with the high temperatures needed for thermal desorption analysis. Since a major objective of the study was to develop viable instrumentation and methodology, a relatively detailed description of the instrumentation design requirements and present limitations are discussed. The results of several series of methodology validation studies are also presented. These studies included recovery studies of model VOC spiked on three types of Tenax sampling devices including authentic actively pumped (VOST) and passive (EPA) devices. Replicate devices spiked in an exposure chamber were also subjected to parallel analyses using the new methodology and traditional thermal-desorption gas chromatography

  14. Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples

    NARCIS (Netherlands)

    Lorenzo, M.; Campo, J.; Picó, Y.

    2016-01-01

    Few methods are available for comprehensive organophosphate flame retardants (PFRs) detection in water and wastewater. Gas chromatography has been employed previously, but this approach is less selective, not amenable for use with deuterated standards and can suffer unfavorable fragmentation.

  15. A validated liquid chromatography-tandem mass spectrometry method for the quantitative determination of 4 beta-hydroxycholesterol in human plasma

    NARCIS (Netherlands)

    van de Merbel, Nico C.; Bronsema, Kees J.; van Hout, Mischa W. J.; Nilsson, Ralf; Sillen, Henrik

    2011-01-01

    A novel liquid chromatography-tandem mass spectrometry method is described for the quantitative determination of the endogenous CYP 3A4/5 marker 4 beta-hydroxycholesterol in human K(2)-EDTA plasma. It is based on alkaline hydrolysis to convert esterified to free 4 beta-hydroxycholesterol, followed

  16. A method for screening active components from Chinese herbs by cell membrane chromatography-offline-high performance liquid chromatography/mass spectrometry and an online statistical tool for data processing.

    Science.gov (United States)

    Cao, Yan; Wang, Shaozhan; Li, Yinghua; Chen, Xiaofei; Chen, Langdong; Wang, Dongyao; Zhu, Zhenyu; Yuan, Yongfang; Lv, Diya

    2018-03-09

    Cell membrane chromatography (CMC) has been successfully applied to screen bioactive compounds from Chinese herbs for many years, and some offline and online two-dimensional (2D) CMC-high performance liquid chromatography (HPLC) hyphenated systems have been established to perform screening assays. However, the requirement of sample preparation steps for the second-dimensional analysis in offline systems and the need for an interface device and technical expertise in the online system limit their extensive use. In the present study, an offline 2D CMC-HPLC analysis combined with the XCMS (various forms of chromatography coupled to mass spectrometry) Online statistical tool for data processing was established. First, our previously reported online 2D screening system was used to analyze three Chinese herbs that were reported to have potential anti-inflammatory effects, and two binding components were identified. By contrast, the proposed offline 2D screening method with XCMS Online analysis was applied, and three more ingredients were discovered in addition to the two compounds revealed by the online system. Then, cross-validation of the three compounds was performed, and they were confirmed to be included in the online data as well, but were not identified there because of their low concentrations and lack of credible statistical approaches. Last, pharmacological experiments showed that these five ingredients could inhibit IL-6 release and IL-6 gene expression on LPS-induced RAW cells in a dose-dependent manner. Compared with previous 2D CMC screening systems, this newly developed offline 2D method needs no sample preparation steps for the second-dimensional analysis, and it is sensitive, efficient, and convenient. It will be applicable in identifying active components from Chinese herbs and practical in discovery of lead compounds derived from herbs. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Two-Dimensional Liquid Chromatography Analysis of Polystyrene/Polybutadiene Block Copolymers.

    Science.gov (United States)

    Lee, Sanghoon; Choi, Heejae; Chang, Taihyun; Staal, Bastiaan

    2018-05-15

    A detailed characterization of a commercial polystyrene/polybutadiene block copolymer material (Styrolux) was carried out using two-dimensional liquid chromatography (2D-LC). The Styrolux is prepared by statistical linking reaction of two different polystyrene- block-polybutadienyl anion precursors with a multivalent linking agent. Therefore, it is a mixture of a number of branched block copolymers different in molecular weight, composition, and chain architecture. While individual LC analysis, including size exclusion chromatography, interaction chromatography, or liquid chromatography at critical condition, is not good enough to resolve all the polymer species, 2D-LC separations coupling two chromatography methods were able to resolve all polymer species present in the sample; at least 13 block copolymer species and a homopolystyrene blended. Four different 2D-LC analyses combining a different pair of two LC methods provide their characteristic separation results. The separation characteristics of the 2D-LC separations are compared to elucidate the elution characteristics of the block copolymer species.

  18. Liquid chromatography and supercritical fluid chromatography as alternative techniques to gas chromatography for the rapid screening of anabolic agents in urine.

    Science.gov (United States)

    Desfontaine, Vincent; Nováková, Lucie; Ponzetto, Federico; Nicoli, Raul; Saugy, Martial; Veuthey, Jean-Luc; Guillarme, Davy

    2016-06-17

    This work describes the development of two methods involving supported liquid extraction (SLE) sample treatment followed by ultra-high performance liquid chromatography or ultra-high performance supercritical fluid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS and UHPSFC-MS/MS) for the screening of 43 anabolic agents in human urine. After evaluating different stationary phases, a polar-embedded C18 and a diol columns were selected for UHPLC-MS/MS and UHPSFC-MS/MS, respectively. Sample preparation, mobile phases and MS conditions were also finely tuned to achieve highest selectivity, chromatographic resolution and sensitivity. Then, the performance of these two methods was compared to the reference routine procedure for steroid analyses in anti-doping laboratories, which combines liquid-liquid extraction (LLE) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). For this purpose, urine samples spiked with the compounds of interest at five different concentrations were analyzed using the three analytical platforms. The retention and selectivity of the three techniques were very different, ensuring a good complementarity. However, the two new methods displayed numerous advantages. The overall procedure was much faster thanks to high throughput SLE sample treatment using 48-well plates and faster chromatographic analysis. Moreover, the highest sensitivity was attained using UHPLC-MS/MS with 98% of the doping agents detected at the lowest concentration level (0.1ng/mL), against 76% for UHPSFC-MS/MS and only 14% for GC-MS/MS. Finally, the weakest matrix effects were obtained with UHPSFC-MS/MS with 76% of the analytes displaying relative matrix effect between -20 and 20%, while the GC-MS/MS reference method displayed very strong matrix effects (over 100%) for all of the anabolic agents. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Interlaboratory study of a liquid chromatography method for erythromycin: determination of uncertainty.

    Science.gov (United States)

    Dehouck, P; Vander Heyden, Y; Smeyers-Verbeke, J; Massart, D L; Marini, R D; Chiap, P; Hubert, Ph; Crommen, J; Van de Wauw, W; De Beer, J; Cox, R; Mathieu, G; Reepmeyer, J C; Voigt, B; Estevenon, O; Nicolas, A; Van Schepdael, A; Adams, E; Hoogmartens, J

    2003-08-22

    Erythromycin is a mixture of macrolide antibiotics produced by Saccharopolyspora erythreas during fermentation. A new method for the analysis of erythromycin by liquid chromatography has previously been developed. It makes use of an Astec C18 polymeric column. After validation in one laboratory, the method was now validated in an interlaboratory study. Validation studies are commonly used to test the fitness of the analytical method prior to its use for routine quality testing. The data derived in the interlaboratory study can be used to make an uncertainty statement as well. The relationship between validation and uncertainty statement is not clear for many analysts and there is a need to show how the existing data, derived during validation, can be used in practice. Eight laboratories participated in this interlaboratory study. The set-up allowed the determination of the repeatability variance, s(2)r and the between-laboratory variance, s(2)L. Combination of s(2)r and s(2)L results in the reproducibility variance s(2)R. It has been shown how these data can be used in future by a single laboratory that wants to make an uncertainty statement concerning the same analysis.

  20. Automatic Recognition Method for Optical Measuring Instruments Based on Machine Vision

    Institute of Scientific and Technical Information of China (English)

    SONG Le; LIN Yuchi; HAO Liguo

    2008-01-01

    Based on a comprehensive study of various algorithms, the automatic recognition of traditional ocular optical measuring instruments is realized. Taking a universal tools microscope (UTM) lens view image as an example, a 2-layer automatic recognition model for data reading is established after adopting a series of pre-processing algorithms. This model is an optimal combination of the correlation-based template matching method and a concurrent back propagation (BP) neural network. Multiple complementary feature extraction is used in generating the eigenvectors of the concurrent network. In order to improve fault-tolerance capacity, rotation invariant features based on Zernike moments are extracted from digit characters and a 4-dimensional group of the outline features is also obtained. Moreover, the operating time and reading accuracy can be adjusted dynamically by setting the threshold value. The experimental result indicates that the newly developed algorithm has optimal recognition precision and working speed. The average reading ratio can achieve 97.23%. The recognition method can automatically obtain the results of optical measuring instruments rapidly and stably without modifying their original structure, which meets the application requirements.

  1. Metabolomics by Gas Chromatography-Mass Spectrometry: the combination of targeted and untargeted profiling

    Science.gov (United States)

    Fiehn, Oliver

    2016-01-01

    Gas chromatography-mass spectrometry (GC-MS)-based metabolomics is ideal for identifying and quantitating small molecular metabolites (metabolomics easily allows integrating targeted assays for absolute quantification of specific metabolites with untargeted metabolomics to discover novel compounds. Complemented by database annotations using large spectral libraries and validated, standardized standard operating procedures, GC-MS can identify and semi-quantify over 200 compounds per study in human body fluids (e.g., plasma, urine or stool) samples. Deconvolution software enables detection of more than 300 additional unidentified signals that can be annotated through accurate mass instruments with appropriate data processing workflows, similar to liquid chromatography-MS untargeted profiling (LC-MS). Hence, GC-MS is a mature technology that not only uses classic detectors (‘quadrupole’) but also target mass spectrometers (‘triple quadrupole’) and accurate mass instruments (‘quadrupole-time of flight’). This unit covers the following aspects of GC-MS-based metabolomics: (i) sample preparation from mammalian samples, (ii) acquisition of data, (iii) quality control, and (iv) data processing. PMID:27038389

  2. Methods and instrumentation for quantitative microchip capillary electrophoresis

    NARCIS (Netherlands)

    Revermann, T.

    2007-01-01

    The development of novel instrumentation and analytical methodology for quantitative microchip capillary electrophoresis (MCE) is described in this thesis. Demanding only small quantities of reagents and samples, microfluidic instrumentation is highly advantageous. Fast separations at high voltages

  3. Improved method for the determination of serotonin in plasma by high-performance liquid chromatography using on-line sample pre-treatment

    NARCIS (Netherlands)

    Takkenberg, B.; Endert, E.; van Ingen, H. E.; Ackermans, M.

    1991-01-01

    An improved method for the determination of serotonin in platelet-rich plasma (PRP) and platelet-poor plasma (PPP), by reversed-phase high-performance liquid chromatography with electrochemical detection and direct plasma injection, is described. The chromatographic system comprises a strong

  4. A liquid chromatography-mass spectrometry method for the quantification of bioavailability and bioconversion of beta-carotene to retinol in humans

    NARCIS (Netherlands)

    Yan Wang,; Xiaoying Xu,; Lieshout, van M.; West, C.E.; Lugtenburg, J.; Verhoeven, M.A.; Creemers, A.F.L.

    2000-01-01

    A method based on high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (APCI LC-MS) was developed for the quantification of the bioavailability of retinyl palmitate and -carotene and the bioconversion of -carotene to retinol in humans. Following oral

  5. Assessing learning outcomes in middle-division classical mechanics: The Colorado Classical Mechanics and Math Methods Instrument

    Directory of Open Access Journals (Sweden)

    Marcos D. Caballero

    2017-04-01

    Full Text Available Reliable and validated assessments of introductory physics have been instrumental in driving curricular and pedagogical reforms that lead to improved student learning. As part of an effort to systematically improve our sophomore-level classical mechanics and math methods course (CM 1 at CU Boulder, we have developed a tool to assess student learning of CM 1 concepts in the upper division. The Colorado Classical Mechanics and Math Methods Instrument (CCMI builds on faculty consensus learning goals and systematic observations of student difficulties. The result is a 9-question open-ended post test that probes student learning in the first half of a two-semester classical mechanics and math methods sequence. In this paper, we describe the design and development of this instrument, its validation, and measurements made in classes at CU Boulder and elsewhere.

  6. A single-run liquid chromatography mass spectrometry method to quantify neuroactive kynurenine pathway metabolites in rat plasma.

    Science.gov (United States)

    Orsatti, Laura; Speziale, Roberto; Orsale, Maria Vittoria; Caretti, Fulvia; Veneziano, Maria; Zini, Matteo; Monteagudo, Edith; Lyons, Kathryn; Beconi, Maria; Chan, Kelvin; Herbst, Todd; Toledo-Sherman, Leticia; Munoz-Sanjuan, Ignacio; Bonelli, Fabio; Dominguez, Celia

    2015-03-25

    Neuroactive metabolites in the kynurenine pathway of tryptophan catabolism are associated with neurodegenerative disorders. Tryptophan is transported across the blood-brain barrier and converted via the kynurenine pathway to N-formyl-L-kynurenine, which is further degraded to L-kynurenine. This metabolite can then generate a group of metabolites called kynurenines, most of which have neuroactive properties. The association of tryptophan catabolic pathway alterations with various central nervous system (CNS) pathologies has raised interest in analytical methods to accurately quantify kynurenines in body fluids. We here describe a rapid and sensitive reverse-phase HPLC-MS/MS method to quantify L-kynurenine (KYN), kynurenic acid (KYNA), 3-hydroxy-L-kynurenine (3HK) and anthranilic acid (AA) in rat plasma. Our goal was to quantify these metabolites in a single run; given their different physico-chemical properties, major efforts were devoted to develop a chromatography suitable for all metabolites that involves plasma protein precipitation with acetonitrile followed by chromatographic separation by C18 RP chromatography, detected by electrospray mass spectrometry. Quantitation range was 0.098-100 ng/ml for 3HK, 9.8-20,000 ng/ml for KYN, 0.49-1000 ng/ml for KYNA and AA. The method was linear (r>0.9963) and validation parameters were within acceptance range (calibration standards and QC accuracy within ±30%). Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Using method triangulation to validate a new instrument (CPWQ-com) assessing cancer patients' satisfaction with communication

    DEFF Research Database (Denmark)

    Ross, Lone; Lundstrøm, Louise Hyldborg; Petersen, Morten Aagaard

    2012-01-01

    Patients' perceptions of care including the communication with health care staff is recognized as an important aspect of the quality of cancer care. Using mixed methods, we developed and validated a short instrument assessing this communication.......Patients' perceptions of care including the communication with health care staff is recognized as an important aspect of the quality of cancer care. Using mixed methods, we developed and validated a short instrument assessing this communication....

  8. New highly sensitive method of simultaneous instrumental neutron activation determination of 12 microelements in vine

    International Nuclear Information System (INIS)

    Shoniya, N.I.

    1977-01-01

    The main principles and methods of simultaneous multi-element instrumental neutron activation determination of microelements in vine seeds are presented. The methods permit to carry out quantitative evaluation for every single corn of the seeds. It is shown that the method of instrumental neutron activation analysis with the utilization of a semiconductor spectrometer of high resolution and mini electronic computer permit to carry out serial determinations of 12 microelements in the individual corns of vine seeds of different sorts. This method will permit to determine the missing or excess content of this or that biologically important microelement in soils, plants, fruit and genetic material - seeds, and so to determine the optimum conditions of growing plants by applying microelement fertilizers as extra nutrient means

  9. Method optimization and quality assurance in speciation analysis using high performance liquid chromatography with detection by inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt

    1998-01-01

    Achievement of optimum selectivity, sensitivity and robustness in speciation analysis using high performance liquid chromatography (HPLC) with inductively coupled mass spectrometry (ICP-MS) detection requires that each instrumental component is selected and optimized with a view to the ideal....... The optimized anion and cation exchange HPLC-ICP-MS systems were used for arsenic speciation in contaminated ground water and in an in-house shrimp reference sample. For the purpose of verification, HPLC coupled with tandem mass spectrometry with electrospray ionization was additionally used for arsenic...... a mass balance of the analytes in each fraction of the extraction procedure, by recovery of spikes and by employing and comparing independent techniques. The urgent need for reference materials certified for elemental species is stressed....

  10. A GC Instrument Simulator

    Science.gov (United States)

    Armitage, D. Bruce

    1999-02-01

    the difference between the boiling point of the component and the temperature of the column. The polarity difference between the column packing and the component is also used to modify the retention time. The retention time decreases as the difference between the boiling point of the component and the temperature of the column increases, and retention time increases as the polarity of the component approaches the polarity of the column. If the temperature of the column is too low, a warning message is given and the chromatogram does not show that component. There is no "carry-over" to the next chromatogram, as might be the case for an actual instrument. Carrier-gas flow rate is fixed and is not part of the retention-time calculation. Because of this latter condition and the method used to determine retention time, this simulator is not useful for gas chromatography method development and is not intended for such use. The purpose of the simulator is to give a beginning student experience in what happens as column temperature is varied, why one might need temperature programming, why an autosampler might be useful, and the pitfalls of "smart" integrators. When students make mistakes in instrument setup with the simulator the consequences are not damaging to the simulator but might cause serious problems with a real instrument. Hardware and Software Requirements Hardware and software requirements for A GC Instrument Simulator are shown in Table 1. right> right> Shown (right to left) are the main instrument control window and the manual injection window from A GC Instrument Simulator.

  11. Analytical Method Validation of High-Performance Liquid Chromatography and Stability-Indicating Study of Medroxyprogesterone Acetate Intravaginal Sponges

    Directory of Open Access Journals (Sweden)

    Nidal Batrawi

    2017-02-01

    Full Text Available Medroxyprogesterone acetate is widely used in veterinary medicine as intravaginal dosage for the synchronization of breeding cycle in ewes and goats. The main goal of this study was to develop reverse-phase high-performance liquid chromatography method for the quantification of medroxyprogesterone acetate in veterinary vaginal sponges. A single high-performance liquid chromatography/UV isocratic run was used for the analytical assay of the active ingredient medroxyprogesterone. The chromatographic system consisted of a reverse-phase C18 column as the stationary phase and a mixture of 60% acetonitrile and 40% potassium dihydrogen phosphate buffer as the mobile phase; the pH was adjusted to 5.6. The method was validated according to the International Council for Harmonisation (ICH guidelines. Forced degradation studies were also performed to evaluate the stability-indicating properties and specificity of the method. Medroxyprogesterone was eluted at 5.9 minutes. The linearity of the method was confirmed in the range of 0.0576 to 0.1134 mg/mL ( R 2 > 0.999. The limit of quantification was shown to be 3.9 µg/mL. Precision and accuracy ranges were found to be %RSD <0.2 and 98% to 102%, respectively. Medroxyprogesterone capacity factor value of 2.1, tailing factor value of 1.03, and resolution value of 3.9 were obtained in accordance with ICH guidelines. Based on the obtained results, a rapid, precise, accurate, sensitive, and cost-effective analysis procedure was proposed for quantitative determination of medroxyprogesterone in vaginal sponges. This analytical method is the only available method to analyse medroxyprogesterone in veterinary intravaginal dosage form.

  12. Optimization and validation of liquid chromatography and headspace-gas chromatography based methods for the quantitative determination of capsaicinoids, salicylic acid, glycol monosalicylate, methyl salicylate, ethyl salicylate, camphor and l-menthol in a topical formulation.

    Science.gov (United States)

    Pauwels, Jochen; D'Autry, Ward; Van den Bossche, Larissa; Dewever, Cédric; Forier, Michel; Vandenwaeyenberg, Stephanie; Wolfs, Kris; Hoogmartens, Jos; Van Schepdael, Ann; Adams, Erwin

    2012-02-23

    Capsaicinoids, salicylic acid, methyl and ethyl salicylate, glycol monosalicylate, camphor and l-menthol are widely used in topical formulations to relieve local pain. For each separate compound or simple mixtures, quantitative analysis methods are reported. However, for a mixture containing all above mentioned active compounds, no assay methods were found. Due to the differing physicochemical characteristics, two methods were developed and optimized simultaneously. The non-volatile capsaicinoids, salicylic acid and glycol monosalicylate were analyzed with liquid chromatography following liquid-liquid extraction, whereas the volatile compounds were analyzed with static headspace-gas chromatography. For the latter method, liquid paraffin was selected as compatible dilution solvent. The optimized methods were validated in terms of specificity, linearity, accuracy and precision in a range of 80% to 120% of the expected concentrations. For both methods, peaks were well separated without interference of other compounds. Linear relationships were demonstrated with R² values higher than 0.996 for all compounds. Accuracy was assessed by performing replicate recovery experiments with spiked blank samples. Mean recovery values were all between 98% and 102%. Precision was checked at three levels: system repeatability, method precision and intermediate precision. Both methods were found to be acceptably precise at all three levels. Finally, the method was successfully applied to the analysis of some real samples (cutaneous sticks). Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Chromatography related performance of the Monitor for AeRosols and GAses in ambient air (MARGA: laboratory and field-based evaluation

    Directory of Open Access Journals (Sweden)

    X. Chen

    2017-10-01

    Full Text Available Evaluation of the semi-continuous Monitor for AeRosols and GAses in ambient air (MARGA, Metrohm Applikon B.V. was conducted with an emphasis on examination of accuracy and precision associated with processing of chromatograms. Using laboratory standards and atmospheric measurements, analytical accuracy, precision and method detection limits derived using the commercial MARGA software were compared to an alternative chromatography procedure consisting of a custom Java script to reformat raw MARGA conductivity data and Chromeleon (Thermo Scientific Dionex software for peak integration. Our analysis revealed issues with accuracy and precision resulting from misidentification and misintegration of chromatograph peaks by the MARGA automated software as well as a systematic bias at low concentrations for anions. Reprocessing and calibration of raw MARGA data using the alternative chromatography method lowered method detection limits and reduced variability (precision between parallel sampler boxes. Instrument performance was further evaluated during a 1-month intensive field campaign in the fall of 2014, including analysis of diurnal patterns of gaseous and particulate water-soluble species (NH3, SO2, HNO3, NH4+, SO42− and NO3−, gas-to-particle partitioning and particle neutralization state. At ambient concentrations below  ∼  1 µg m−3, concentrations determined using the MARGA software are biased +30 and +10 % for NO3− and SO42−, respectively, compared to concentrations determined using the alternative chromatography procedure. Differences between the two methods increase at lower concentrations. We demonstrate that positively biased NO3− and SO42− measurements result in overestimation of aerosol acidity and introduce nontrivial errors to ion balances of inorganic aerosol. Though the source of the bias is uncertain, it is not corrected by the MARGA online single-point internal LiBr standard. Our results show that

  14. Chromatography related performance of the Monitor for AeRosols and GAses in ambient air (MARGA): laboratory and field-based evaluation

    Science.gov (United States)

    Chen, Xi; Walker, John T.; Geron, Chris

    2017-10-01

    Evaluation of the semi-continuous Monitor for AeRosols and GAses in ambient air (MARGA, Metrohm Applikon B.V.) was conducted with an emphasis on examination of accuracy and precision associated with processing of chromatograms. Using laboratory standards and atmospheric measurements, analytical accuracy, precision and method detection limits derived using the commercial MARGA software were compared to an alternative chromatography procedure consisting of a custom Java script to reformat raw MARGA conductivity data and Chromeleon (Thermo Scientific Dionex) software for peak integration. Our analysis revealed issues with accuracy and precision resulting from misidentification and misintegration of chromatograph peaks by the MARGA automated software as well as a systematic bias at low concentrations for anions. Reprocessing and calibration of raw MARGA data using the alternative chromatography method lowered method detection limits and reduced variability (precision) between parallel sampler boxes. Instrument performance was further evaluated during a 1-month intensive field campaign in the fall of 2014, including analysis of diurnal patterns of gaseous and particulate water-soluble species (NH3, SO2, HNO3, NH4+, SO42- and NO3-), gas-to-particle partitioning and particle neutralization state. At ambient concentrations below ˜ 1 µg m-3, concentrations determined using the MARGA software are biased +30 and +10 % for NO3- and SO42-, respectively, compared to concentrations determined using the alternative chromatography procedure. Differences between the two methods increase at lower concentrations. We demonstrate that positively biased NO3- and SO42- measurements result in overestimation of aerosol acidity and introduce nontrivial errors to ion balances of inorganic aerosol. Though the source of the bias is uncertain, it is not corrected by the MARGA online single-point internal LiBr standard. Our results show that calibration and verification of instrument accuracy

  15. An optimized method for fatty acid analysis, including quantification of trans fatty acids, in human adipose tissue by gas-liquid chromatography

    DEFF Research Database (Denmark)

    Bysted, Anette; Cold, S; Hølmer, Gunhild Kofoed

    1999-01-01

    Considering the need for a quick direct method for measurement of the fatty acid composition including trans isomers ofhuman adipose tissue we have developed a procedure using gas-liquid chromatography (GLC) alone, which is thussuitable for validation of fatty acid status in epidemiological studies...... for 25 min, and finally raised at 25 degrees C/min to 225 degrees C. The trans and cis isomers of18:1 were well separated from each other, as shown by silver-ion thin-layer chromatography. Verification by standardsshowed that the trans 18:1 isomers with a double bond in position 12 or lower were...

  16. A Method of Separation Assurance for Instrument Flight Procedures at Non-Radar Airports

    Science.gov (United States)

    Conway, Sheila R.; Consiglio, Maria

    2002-01-01

    A method to provide automated air traffic separation assurance services during approach to or departure from a non-radar, non-towered airport environment is described. The method is constrained by provision of these services without radical changes or ambitious investments in current ground-based technologies. The proposed procedures are designed to grant access to a large number of airfields that currently have no or very limited access under Instrument Flight Rules (IFR), thus increasing mobility with minimal infrastructure investment. This paper primarily addresses a low-cost option for airport and instrument approach infrastructure, but is designed to be an architecture from which a more efficient, albeit more complex, system may be developed. A functional description of the capabilities in the current NAS infrastructure is provided. Automated terminal operations and procedures are introduced. Rules of engagement and the operations are defined. Results of preliminary simulation testing are presented. Finally, application of the method to more terminal-like operations, and major research areas, including necessary piloted studies, are discussed.

  17. Confirmatory analysis method for zeranol, its metabolites and related mycotoxins in urine by liquid chromatography-negative ion electrospray tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Bennekom, E.O. van; Brouwer, L.; Laurant, E.H.M.; Hooijerink, H.; Nielen, M.W.F

    2002-11-25

    The determination of the banned anabolic substance zeranol and the metabolites taleranol and zearalanone in bovine urine is complicated by the occurrence of the structurally-related mycotoxin zearalenone and the corresponding {alpha}- and {beta}-zearalenol metabolites which possess similar estrogenic properties. A liquid chromatography-negative ion electrospray tandem mass spectrometric method is presented for the confirmatory analysis of all six resorcylic acid lactones ('zeranols') in urine samples using deuterium-labelled internal standards. The method was validated as a confirmatory method for bovine urine samples according to new draft EU guidelines and showed good precision and linearity, and CC{alpha} and CC{beta} values of 0.02-0.30 and <1.0 ng ml{sup -1}, respectively. The applicability was demonstrated by comparing the results of an incurred sample with previous results on the same sample obtained by gas chromatography high resolution mass spectrometry. Preliminary data show that following a simple matrix solid phase dispersion clean-up, liver samples from poultry will be amenable to this method as well.

  18. Validation of the Mass-Extraction-Window for Quantitative Methods Using Liquid Chromatography High Resolution Mass Spectrometry.

    Science.gov (United States)

    Glauser, Gaétan; Grund, Baptiste; Gassner, Anne-Laure; Menin, Laure; Henry, Hugues; Bromirski, Maciej; Schütz, Frédéric; McMullen, Justin; Rochat, Bertrand

    2016-03-15

    A paradigm shift is underway in the field of quantitative liquid chromatography-mass spectrometry (LC-MS) analysis thanks to the arrival of recent high-resolution mass spectrometers (HRMS). The capability of HRMS to perform sensitive and reliable quantifications of a large variety of analytes in HR-full scan mode is showing that it is now realistic to perform quantitative and qualitative analysis with the same instrument. Moreover, HR-full scan acquisition offers a global view of sample extracts and allows retrospective investigations as virtually all ionized compounds are detected with a high sensitivity. In time, the versatility of HRMS together with the increasing need for relative quantification of hundreds of endogenous metabolites should promote a shift from triple-quadrupole MS to HRMS. However, a current "pitfall" in quantitative LC-HRMS analysis is the lack of HRMS-specific guidance for validated quantitative analyses. Indeed, false positive and false negative HRMS detections are rare, albeit possible, if inadequate parameters are used. Here, we investigated two key parameters for the validation of LC-HRMS quantitative analyses: the mass accuracy (MA) and the mass-extraction-window (MEW) that is used to construct the extracted-ion-chromatograms. We propose MA-parameters, graphs, and equations to calculate rational MEW width for the validation of quantitative LC-HRMS methods. MA measurements were performed on four different LC-HRMS platforms. Experimentally determined MEW values ranged between 5.6 and 16.5 ppm and depended on the HRMS platform, its working environment, the calibration procedure, and the analyte considered. The proposed procedure provides a fit-for-purpose MEW determination and prevents false detections.

  19. New EDTA determination method based on ion chromatography with suppressed conductimetric detection

    International Nuclear Information System (INIS)

    Gyoergy Patzay; Yahya Ramadan; Csilla Tonko

    2014-01-01

    A novel direct method for the determination of EDTA in alkaline radioactive evaporator residue solution was developed and validated based on ion chromatography with suppressed conductimetric detection and anion exchange columns (A Supp 4, 4 mm × 250 mm and A Supp 5, 4 mm × 150 mm). The yttrium-EDTA complex resulted one single chromatographic peak in the eluent and allowed the correct determination of EDTA in an alkaline, high concentration radioactive waste water. Depending on coexisting substances, suitable eluent is 10.0 mM carbonate buffer/pH 10.6 or 10.75 (t R ,Y-EDTA = 7.01 and 6.4 min, respectively). For 10.0 mM carbonate buffer/pH 10.6 and isocratic flow rate of 1.0 cm 3 /min, a linear calibration curve was obtained from 5 to 40 mg/dm 3 (r > 0.999) EDTA. Good resolution was achieved from commonly coexisting anions (chloride, nitrite, nitrate, sulphate, phosphate, bromide and citrate). The developed simple ion chromatographic method was applied for the assay of EDTA in various radioactive alkaline solutions. (author)

  20. Thin-layer chromatography - liquid chromatography, an ideal supplement demonstrated by the separation of lanthanoids

    International Nuclear Information System (INIS)

    Specker, H.; Hufnagel, A.

    1984-01-01

    All lanthanoids have been separated by thin-layer chromatography (TLC) with short retention times by using a mixture of ether/tetrahydrofurane (THF)/bis-(2-ethylhexyl)-phosphate (HDEHP)/nitric acid. The eluent was empirically tested by synergistic effects. The results have been transferred to high-performance liquid chromatography /HPLC). It was possible to use the same eluent in TLC and HPLC both for the analytical separation of all lanthanoids and for the separation of fission products. The experimental experience gained in HPLC could be applied to the pre-concentration of isotopes in TLC. Both methods excellently supplemented each other in the separation of lanthanoids. (orig.) [de

  1. The analysis of aqueous mixtures using liquid chromatography-electrospray mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Steven [Iowa State Univ., Ames, IA (United States)

    1999-02-12

    The focus of this dissertation is the use of chromatographic methods coupled with electrospray mass spectrometry (ES-MS) for the determination of both organic and inorganic compounds in aqueous solutions. The combination of liquid chromatography (LC) methods and ES-MS offers one of the foremost methods for determining compounds in complex aqueous solutions. In this work, LC-ES-MS methods are devised using ion exclusion chromatography, reversed phase chromatography, and ion exchange chromatography, as well as capillary electrophoresis (CE). For an aqueous sample, these LC-ES-MS and CE-ES-MS techniques require no sample preparation or analyte derivatization, which makes it possible to observe a wide variety of analytes as they exist in solution. The majority of this work focuses on the use of LC-ES-MS for the determination of unknown products and intermediates formed during electrochemical incineration (ECI), an experimental waste remediation process. This report contains a general introduction to the project and the general conclusions. Four chapters have been removed for separate processing. Titles are: Chapter 2: Determination of small carboxylic acids by ion exclusion chromatography with electrospray mass spectrometry; Chapter 3: Electrochemical incineration of benzoquinone in aqueous media using a quaternary metal oxide electrode in the absence of a soluble supporting electrolyte; Chapter 4: The determination of electrochemical incineration products of 4-chlorophenol by liquid chromatography-electrospray mass spectrometry; and Chapter 5: Determination of small carboxylic acids by capillary electrophoresis with electrospray mass spectrometry.

  2. Determination of nucleosides in Cordyceps sinensis and Ganoderma lucidum by high performance liquid chromatography method

    Directory of Open Access Journals (Sweden)

    Masood Shah Khan

    2015-01-01

    Full Text Available Background: Nucleosides are supportive in the regulation and modulation of various physiological processes in body, they acts as precursors in nucleic acid synthesis, enhance immune response, help in absorption of iron and influence the metabolism of fatty acids. Cordyceps sinensis and Ganoderma lucidum are well-known for its use in traditional medicine of China, Nepal and India. They are rich in nucleosides such as adenine, adenosine, cordycepin, etc. Hence, a simple, economic and accurate high-performance liquid chromatography (HPLC analytical method was proposed for determination of adenine and adenosine for the quality control of plants. Materials and Methods: Chromatographic experiments were conducted on YL9100 HPLC system (South Korea. Reversed-phase chromatography was performed on a C18 column with methanol and dihydrogen phosphate as the mobile phase in isocratic elution method at a flow rate of 1.0 mL/min. Detection was carried out at 254 nm, which gives a sharp peak of adenine and adenosine at a retention time of 6.53 ± 0.02 min and 12.41 ± 0.02, respectively. Results and Discussion: Linear regression analysis data for the calibration plot showed a good linear relationship between response and concentration in the range of 25–200 µg/mL for adenosine and 100–800 µg/mL for adenine with regression coefficient of 0.999 and 0.996, respectively. The adenine was found 0.16% and 0.71% w/w in G. lucidum and in C. sinensis, respectively, and adenosine was found to be 0.14% w/w in G. lucidum whereas absent in C. sinensis. Conclusion: The developed HPLC method for the quantification of adenosine and adenine can be used for the quality control and standardization of crude drug and for the different herbal formulations, in which adenine and adenosine are present as major constituents. The wide linearity range, sensitivity, accuracy, and simple mobile phase imply the method is suitable for routine quantification of adenosine and adenine with

  3. Evaluation of a new preparative supercritical fluid chromatography system for compound library purification: the TharSFC SFC-MS Prep-100 system.

    Science.gov (United States)

    Ebinger, Katalin; Weller, Harold N; Kiplinger, Jeffrey; Lefebvre, Paul

    2011-06-01

    Preparative HPLC-MS is often the method of choice for purification of small amounts (libraries for drug discovery. The method is robust, well proven, and widely applicable. In contrast, preparative supercritical fluid chromatography coupled with mass spectrometry (SFC-MS) has seen only slow acceptance for the same application--despite some potential scientific and economic advantages. One of the reasons for slow adoption of SFC-MS is the lack of well-proven, robust, and commercially available instrumentation. In early 2009, TharSFC (a Waters Company, Pittsburgh, PA) introduced a new fully integrated system for preparative SFC-MS: The SFC-MS Prep-100. We report herein an objective evaluation of the SFC-MS Prep-100, including tests for pump and autosampler performance, sample recovery, sample carryover, fraction triggering, detector/fraction collector synchronization, and overall robustness. Our results suggest that the SFC-MS Prep-100 represents a significant advance over previous generation instrumentation. Copyright © 2011 Society for Laboratory Automation and Screening. Published by Elsevier Inc. All rights reserved.

  4. Validation of ascorbic acid tablets of national production by igh-performance liquid chromatography method

    International Nuclear Information System (INIS)

    Rodriguez Hernandez, Yaslenis; Suarez Perez, Yania; Izquierdo Castro, Idalberto

    2009-01-01

    We validate an analytical method by high-performance liquid chromatography to determine ascorbic acid proportion in vitamin C tablets, which was designed as an alternative method to quality control and to follow-up of active principle chemical stability, since official techniques to quality control of ascorbic acid in tablets are not selective with degradation products. Method was modified according to that reported in USP 28, 2005 for analysis of injectable product. We used a RP-18 column of 250 x 4.6 mm 5 μm with a UV detector to 245 nm. Its validation was necessary for both objectives, considering parameters required for methods of I and II categories. This method was enough linear, exact, and precise in the rank of 100-300 μg/mL. Also, it was selective with remaining components of matrix and with the possible degradation products achieved in stressing conditions. Detection and quantification limits were estimated. When method was validated it was applied to ascorbic acid quantification in two batches of expired tablets and we detected a marked influence of container in active degradation principle after 12 months at room temperature. (Author)

  5. Novel analytical methods for characterising binding media and protective coatings in artworks

    International Nuclear Information System (INIS)

    Domenech-Carbo, Maria Teresa

    2008-01-01

    Since the first reported analytical studies and technical examinations of art and archaeological objects conducted in the late 18th century, analytical techniques and methods applied to the study of artworks have constantly grown. Among the materials composing the art object, organic compounds used as binding media or protective coatings have attracted the attention of the conservation profession given their noticeable ability for undergoing morphological and chemical changes on ageing. Thus, the aim of this paper is to review the most recent advances in the identification and determination of organic compounds present in art and art conservation materials. Immunofluorescence techniques have been proposed in recent decades as an alternative to the classical and simpler microchemical tests. Besides, a variety of instrumental techniques have also been improved in an attempt to enhance the sensitivity, repeatability and accuracy of the analytical results. Spectroscopic techniques, such as UV-vis, FTIR and Raman spectroscopy, have been coupled with light microscopes for these purposes. Synchrotron radiation FTIR microspectroscopy has also been successfully applied to the analysis of artworks. Mass spectrometry has also been increasingly used as a detector system coupled with a chromatographic device. Chromatographic methods have also improved in recent years. Paper and thin layer chromatographic techniques have been progressively replaced with gas chromatography (GC), pyrolysis-GC, high performance liquid chromatography and capillary electrophoresis. More complex proteomics hyphenated techniques, such as nano-liquid chromatography-nano-electrospray ionisation/collision quadrupole time-of-flight tandem mass spectrometry, have been recently applied to the identification and determination of proteinaceous binders. Microbeam analytical techniques have also been incorporated into the list of advanced instrumental techniques for art conservation purposes. Finally, a number

  6. Novel analytical methods for characterising binding media and protective coatings in artworks

    Energy Technology Data Exchange (ETDEWEB)

    Domenech-Carbo, Maria Teresa [Institut de Restauracio del Patrimoni, Universitat Politecnica de Valencia, Cami de Vera s/n, 46022 Valencia (Spain)], E-mail: tdomenec@crbc.upv.es

    2008-07-28

    Since the first reported analytical studies and technical examinations of art and archaeological objects conducted in the late 18th century, analytical techniques and methods applied to the study of artworks have constantly grown. Among the materials composing the art object, organic compounds used as binding media or protective coatings have attracted the attention of the conservation profession given their noticeable ability for undergoing morphological and chemical changes on ageing. Thus, the aim of this paper is to review the most recent advances in the identification and determination of organic compounds present in art and art conservation materials. Immunofluorescence techniques have been proposed in recent decades as an alternative to the classical and simpler microchemical tests. Besides, a variety of instrumental techniques have also been improved in an attempt to enhance the sensitivity, repeatability and accuracy of the analytical results. Spectroscopic techniques, such as UV-vis, FTIR and Raman spectroscopy, have been coupled with light microscopes for these purposes. Synchrotron radiation FTIR microspectroscopy has also been successfully applied to the analysis of artworks. Mass spectrometry has also been increasingly used as a detector system coupled with a chromatographic device. Chromatographic methods have also improved in recent years. Paper and thin layer chromatographic techniques have been progressively replaced with gas chromatography (GC), pyrolysis-GC, high performance liquid chromatography and capillary electrophoresis. More complex proteomics hyphenated techniques, such as nano-liquid chromatography-nano-electrospray ionisation/collision quadrupole time-of-flight tandem mass spectrometry, have been recently applied to the identification and determination of proteinaceous binders. Microbeam analytical techniques have also been incorporated into the list of advanced instrumental techniques for art conservation purposes. Finally, a number

  7. High perfomance liquid chromatography in pharmaceutical analyses.

    Science.gov (United States)

    Nikolin, Branko; Imamović, Belma; Medanhodzić-Vuk, Saira; Sober, Miroslav

    2004-05-01

    In testing the pre-sale procedure the marketing of drugs and their control in the last ten years, high performance liquid chromatography replaced numerous spectroscopic methods and gas chromatography in the quantitative and qualitative analysis. In the first period of HPLC application it was thought that it would become a complementary method of gas chromatography, however, today it has nearly completely replaced gas chromatography in pharmaceutical analysis. The application of the liquid mobile phase with the possibility of transformation of mobilized polarity during chromatography and all other modifications of mobile phase depending upon the characteristics of substance which are being tested, is a great advantage in the process of separation in comparison to other methods. The greater choice of stationary phase is the next factor which enables realization of good separation. The separation line is connected to specific and sensitive detector systems, spectrafluorimeter, diode detector, electrochemical detector as other hyphernated systems HPLC-MS and HPLC-NMR, are the basic elements on which is based such wide and effective application of the HPLC method. The purpose high performance liquid chromatography (HPLC) analysis of any drugs is to confirm the identity of a drug and provide quantitative results and also to monitor the progress of the therapy of a disease.1) Measuring presented on the Fig. 1. is chromatogram obtained for the plasma of depressed patients 12 h before oral administration of dexamethasone. It may also be used to further our understanding of the normal and disease process in the human body trough biomedical and therapeutically research during investigation before of the drugs registration. The analyses of drugs and metabolites in biological fluids, particularly plasma, serum or urine is one of the most demanding but one of the most common uses of high performance of liquid chromatography. Blood, plasma or serum contains numerous endogenous

  8. Instrumental analysis, second edition

    International Nuclear Information System (INIS)

    Christian, G.D.; O'Reilly, J.E.

    1988-01-01

    The second edition of Instrumental Analysis is a survey of the major instrument-based methods of chemical analysis. It appears to be aimed at undergraduates but would be equally useful in a graduate course. The volume explores all of the classical quantitative methods and contains sections on techniques that usually are not included in a semester course in instrumentation (such as electron spectroscopy and the kinetic methods). Adequate coverage of all of the methods contained in this book would require several semesters of focused study. The 25 chapters were written by different authors, yet the style throughout the book is more uniform than in the earlier edition. With the exception of a two-chapter course in analog and digital circuits, the book purports to de-emphasize instrumentation, focusing more on the theory behind the methods and the application of the methods to analytical problems. However, a detailed analysis of the instruments used in each method is by no means absent. The book has the favor of a user's guide to analysis

  9. Investigation on trace elements in crude oil and organic matter extracted from rocks with instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Ding Zuguo; Chai Zhifang

    1990-01-01

    Solvent extraction, column chromatography and instrumental neutron activation analysis(INAA) have been used to investigate the trace elements in crude oil, organic matter extracted from rocks and their related fractions. With these methods, about 70 crude oil samples from eight different oil fields in China and 6 extracted asphaltene samples of the lower paleozoic from the upper Yangtze region have been analyzed, and about 40 elements of interest have been determined. Those elements include Al, As, Au, Ba, Br, Cl, Co, Cr, Cs, Cu, Fe, Hf, I, Ir, Mg, Mn, Mo, Na, Ni, Rb, Re, S, Sb, Sc, Se, Sr, Th, Zn, V and parts of REE. The experimental results show that the method possesses several advantages, i.e. non-destructive, multi-elements, sensitive, precise and accurate. Without ashing samples, the loss of volatile elements such as Cl, S, Se and Sb are avoided. The column chromatography makes it possible to study the distributions of trace elements in different fractions of crude oil and organic matter extracted. Meanwhile, the characters of trace elements in them have also been discussed

  10. Method transfer from high-pressure liquid chromatography to ultra-high-pressure liquid chromatography. II. Temperature and pressure effects.

    Science.gov (United States)

    Åsberg, Dennis; Samuelsson, Jörgen; Leśko, Marek; Cavazzini, Alberto; Kaczmarski, Krzysztof; Fornstedt, Torgny

    2015-07-03

    The importance of the generated temperature and pressure gradients in ultra-high-pressure liquid chromatography (UHPLC) are investigated and compared to high-pressure liquid chromatography (HPLC). The drug Omeprazole, together with three other model compounds (with different chemical characteristics, namely uncharged, positively and negatively charged) were used. Calculations of the complete temperature profile in the column at UHPLC conditions showed, in our experiments, a temperature difference between the inlet and outlet of 16 °C and a difference of 2 °C between the column center and the wall. Through van't Hoff plots, this information was used to single out the decrease in retention factor (k) solely due to the temperature gradient. The uncharged solute was least affected by temperature with a decrease in k of about 5% while for charged solutes the effect was more pronounced, with k decreases up to 14%. A pressure increase of 500 bar gave roughly 5% increase in k for the uncharged solute, while omeprazole and the other two charged solutes gave about 25, 20 and 15% increases in k, respectively. The stochastic model of chromatography was applied to estimate the dependence of the average number of adsorption/desorption events (n) and the average time spent by a molecule in the stationary phase (τs) on temperature and pressure on peak shape for the tailing, basic solute. Increasing the temperature yielded an increase in n and decrease in τs which resulted in less skew at high temperatures. With increasing pressure, the stochastic modeling gave interesting results for the basic solute showing that the skew of the peak increased with pressure. The conclusion is that pressure effects are more pronounced for both retention and peak shape than the temperature effects for the polar or charged compounds in our study. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Method of determining of polybrominated diphenyl ethers in fish and fish products by the method of liquid chromatography

    Directory of Open Access Journals (Sweden)

    O.N. Timofeeva

    2016-09-01

    Full Text Available The aim of the work was to develop a methodology for determining of polybrominated diphenyl ethers (PBDE in fish and fish products for the control of impurities content in the food and environmental objects in general. The conditions of chromatography (temperature conditions, the impact of the speed and magnitude of dividing of the gas-carrier stream using a HP-1 capillary columns, the DB-5, HP-50 +, DB-1; and lipids destructive and non-destructive cleaning methods of extract during the determination of PBDEs. The method of determination of 2,2,4,4-Tetrabromodiphenyl ether (BDE-47, 2,2,4,4,5-pentabromodiphenyl ether (BDE-99 and decabromodiphenyl ether (BDE-209 in fish and fish products by the liquid chromatography with electron detector was suggested. The method of PBDE is based on the extraction of samples with hexane-acetone (3:1, purification of the extract with concentrated sulfuric acid (phase ratio hexane-sulfuric acid – 5:1. The second purification step is carried out by using solid phase extraction cartridges «SiOH-H2SO4/SA» and hexane as the eluent. Gas chromatographic analysis of the determination of BDE-47 and BDE-99 is carried out on low-polar capillary column DB-5 (30 m x0.25 mm x0.25 mum with the programming of the column temperature. In determining the BDE-209 a DB-1 nonpolar capillary column was used (15 m x 0.25 mm x 0.1 mum with the column temperature programming. Calculation of the content of BDE-47 and BDE-99 is carried out with the internal standard (2,2, 3,4,4-pentabromodiphenyl ether (BDE-85, BDE-209 by absolute calibration. In determining the BDE-209 the calibration matrix was used. The range of concentrations of the calibration solutions for the determination of BDE-47 and BDE-99 is 0.005–0.05 g/cm 3 , for BDE-209 0.05–0.3 g/cm 3 . The technique allows the measurement of BDE-47 and BDE-99 in the range of 0.0002–0.05 mg/kg of the product concerned; BDE-209 – in the range of 0.002–0.3 mg/kg. The metrological

  12. A new method for the assessment of the surface topography of NiTi rotary instruments.

    Science.gov (United States)

    Ferreira, F; Barbosa, I; Scelza, P; Russano, D; Neff, J; Montagnana, M; Zaccaro Scelza, M

    2017-09-01

    To describe a new method for the assessment of nanoscale alterations in the surface topography of nickel-titanium endodontic instruments using a high-resolution optical method and to verify the accuracy of the technique. Noncontact three-dimensional optical profilometry was used to evaluate defects on a size 25, .08 taper reciprocating instrument (WaveOne ® ), which was subjected to a cyclic fatigue test in a simulated root canal in a clear resin block. For the investigation, an original procedure was established for the analysis of similar areas located 3 mm from the tip of the instrument before and after canal preparation to enable the repeatability and reproducibility of the measurements with precision. All observations and analysis were taken in areas measuring 210 × 210 μm provided by the software of the equipment. The three-dimensional high-resolution image analysis showed clear alterations in the surface topography of the examined cutting blade and flute of the instrument, before and after use, with the presence of surface irregularities such as deformations, debris, grooves, cracks, steps and microcavities. Optical profilometry provided accurate qualitative nanoscale evaluation of similar surfaces before and after the fatigue test. The stability and repeatability of the technique enables a more comprehensive understanding of the effects of wear on the surface of endodontic instruments. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  13. Liquid-adsorption chromatography of metal 8-hydroxyquinolinates

    International Nuclear Information System (INIS)

    Basova, E.M.; Bol'shova, T.A.; Shirshova, T.S.

    1988-01-01

    Using the method of liquid-adsorption chromatography separation of 8-hydroxyquinolinates of Cu, Fe, Ga, In, Al, Ni is realized. Thin-layer chromatography (TLC) is used to define the optimum conditions of separation and highly efficient liquid column chromatography (HELC) - for chelate separation. Applicaton of the same sorbent is a very important condition of transition from TLC to HELC. Solica gel Partisil, mobile phase: benzene - isopropanol mixture, containing 1 x 10 -3 M of 8-hydroxyquinoline, are the optimal conditions for the studied chelates separation. But In and Ga in TLC move together, and in HELC they are partially separated, therefore, for their separation the column selectivity should be improved by selection of mobile phase

  14. Analysis of residual toluene in food packaging via headspace extraction method using gas chromatography

    International Nuclear Information System (INIS)

    Lim, Ying Chin; Mohd Marsin Sanagi

    2008-01-01

    Polymeric materials are used in many food contact applications as packaging material. The presence of residual toluene in this food packaging material can migrate into food and thus affect the quality of food. In this study, a manual headspace analysis was successfully designed and developed. The determination of residual toluene was carried out with standard addition method and multiple headspace extraction, MHE) method using gas chromatography-flame ionization detector, GC-FID). Identification of toluene was performed by comparison of its retention time with standard toluene and GC-MS. It was found that the suitable heating temperature was 180 degree Celsius with an optimum heating time of 10 minutes. The study also found that the concentration of residual toluene in multicolored sample was higher compared to mono colored sample whereas residual toluene in sample analyzed using standard addition method was higher compared to MHE method. However, comparison with the results obtained from De Paris laboratory, France found that MHE method gave higher accuracy for sample with low analyte concentration. On the other hand, lower accuracy was obtained for sample with high concentration of residual toluene due to systematic errors. Comparison between determination methods showed that MHE method is more precise compared to standard addition method. (author)

  15. Simplified and rapid method for extraction of ergosterol from natural samples and detection with quantitative and semi-quantitative methods using thin-layer chromatography

    OpenAIRE

    Larsen, Cand.scient Thomas; Ravn, Senior scientist Helle; Axelsen, Senior Scientist Jørgen

    2004-01-01

    A new and simplified method for extraction of ergosterol (ergoste-5,7,22-trien-3-beta-ol) from fungi in soil and litter was developed using pre-soaking extraction and paraffin oil for recovery. Recoveries of ergosterol were in the range of 94 - 100% depending on the solvent to oil ratio. Extraction efficiencies equal to heat-assisted extraction treatments were obtained with pre-soaked extraction. Ergosterol was detected with thin-layer chromatography (TLC) using fluorodensitometry with a quan...

  16. Instruments for radiation measurement in biosciences. Series 3. radioluminography. 1. Results of questionnaires to the scientists using radioluminographic techniques

    International Nuclear Information System (INIS)

    Kurihara, Norio; Nakajima, Eiichi; Takahashi, Sentaro

    1998-01-01

    Radioluminography (RLG) is a method to detect radioactivity with its photostimulated luminescence phenomenon. This paper describes major results of questionnaires to the scientists using RLG technique which was performed by the technical subcommittee for research instruments for isotope tracer of Life Science Section, Japan Radioisotope Association. The main purpose was to find the advantage and problems of RLG recognized by users. Questionnaires were sent to 271 users and 101 answers were obtained from pharmaceutical companies, universities and other public research facilities. RLG was found mainly used in gel electrophoresis in the molecular biology field, thin layer chromatography and quantitative whole body autoradiography. RLG technology itself of the instrument, imaging plate and standard usage was found to be in progress as well. Problems were those on the fundamental handling (e.g., ROI definition), on instruments, on quantitativeness, on different nuclides, on value for formal data and on radiation control. The major instrument manufacturers were Fuji Film Co., BioRad Co. and Molecular Dynamics Co. Results of the questionnaire will be published in more detailed form in future. (K.H.)

  17. An ergonomics based design research method for the arrangement of helicopter flight instrument panels.

    Science.gov (United States)

    Alppay, Cem; Bayazit, Nigan

    2015-11-01

    In this paper, we study the arrangement of displays in flight instrument panels of multi-purpose civil helicopters following a user-centered design method based on ergonomics principles. Our methodology can also be described as a user-interface arrangement methodology based on user opinions and preferences. This study can be outlined as gathering user-centered data using two different research methods and then analyzing and integrating the collected data to come up with an optimal instrument panel design. An interview with helicopter pilots formed the first step of our research. In that interview, pilots were asked to provide a quantitative evaluation of basic interface arrangement principles. In the second phase of the research, a paper prototyping study was conducted with same pilots. The final phase of the study entailed synthesizing the findings from interviews and observational studies to formulate an optimal flight instrument arrangement methodology. The primary results that we present in our paper are the methodology that we developed and three new interface arrangement concepts, namely relationship of inseparability, integrated value and locational value. An optimum instrument panel arrangement is also proposed by the researchers. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  18. Standard test method for verifying the alignment of X-Ray diffraction instrumentation for residual stress measurement

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the preparation and use of a flat stress-free test specimen for the purpose of checking the systematic error caused by instrument misalignment or sample positioning in X-ray diffraction residual stress measurement, or both. 1.2 This test method is applicable to apparatus intended for X-ray diffraction macroscopic residual stress measurement in polycrystalline samples employing measurement of a diffraction peak position in the high-back reflection region, and in which the θ, 2θ, and ψ rotation axes can be made to coincide (see Fig. 1). 1.3 This test method describes the use of iron powder which has been investigated in round-robin studies for the purpose of verifying the alignment of instrumentation intended for stress measurement in ferritic or martensitic steels. To verify instrument alignment prior to stress measurement in other metallic alloys and ceramics, powder having the same or lower diffraction angle as the material to be measured should be prepared in similar fashion...

  19. Qualitative and quantitative temporal analysis of licit and illicit drugs in wastewater in Australia using liquid chromatography coupled to mass spectrometry.

    Science.gov (United States)

    Bade, Richard; White, Jason M; Gerber, Cobus

    2018-01-01

    The combination of qualitative and quantitative bimonthly analysis of pharmaceuticals and illicit drugs using liquid chromatography coupled to mass spectrometry is presented. A liquid chromatography-quadrupole time of flight instrument equipped with Sequential Window Acquisition of all THeoretical fragment-ion spectra (SWATH) was used to qualitatively screen 346 compounds in influent wastewater from two wastewater treatment plants in South Australia over a 14-month period. A total of 100 compounds were confirmed and/or detected using this strategy, with 61 confirmed in all samples including antidepressants (amitriptyline, dothiepin, doxepin), antipsychotics (amisulpride, clozapine), illicit drugs (cocaine, methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine (MDMA)), and known drug adulterants (lidocaine and tetramisole). A subset of these compounds was also included in a quantitative method, analyzed on a liquid chromatography-triple quadrupole mass spectrometer. The use of illicit stimulants (methamphetamine) showed a clear decrease, levels of opioid analgesics (morphine and methadone) remained relatively stable, while the use of new psychoactive substances (methylenedioxypyrovalerone (MDPV) and Alpha PVP) varied with no visible trend. This work demonstrates the value that high-frequency sampling combined with quantitative and qualitative analysis can deliver. Graphical abstract Temporal analysis of licit and illicit drugs in South Australia.

  20. Precision of GNSS instruments by static method comparing in real time

    Directory of Open Access Journals (Sweden)

    Slavomír Labant

    2009-09-01

    Full Text Available Tablet paper describes comparison of measuring accuracy two apparatus from the firm Leica. One of them recieve signals onlyfrom GPS satelites and another instrument is working with GPS and also with GLONASS satelites. Measuring is carry out by RTK staticmethod with 2 minutes observations. Measurement processing is separated to X, Y (position and h (heigh. Adjustment of directobservations is used as a adjusting method.

  1. Instruments and methods of scintillation spectra processing for radiation control tasks

    International Nuclear Information System (INIS)

    Antropov, S.Yu.; Ermilov, A.P.; Ermilov, S.A.; Komarov, N.A.; Krokhin, I.I.

    2005-01-01

    On gamma-spectrometer the response function could be calculated on the base of sensitivity data, energy resolution and form of Compton spectrum part. On the scintillation gamma-spectrometer with Na-I(Tl) crystal 63x63 mm the method allows to divide the 5-10 components mixtures, and on the beta-spectrometer of 2-3 component mixtures. The approach is realized in the 'Progress' program-instrumental complexes

  2. Comparative investigation of the gel chromatography column scanning method for quality control of /sup 99/sup(m)Tc-methylenediphosphonate

    Energy Technology Data Exchange (ETDEWEB)

    Darte, L

    1981-04-01

    Gel chromatography column scanning (GCS) is the method of choice for quality control of sup(99m)Tc-MDP preparations. Using this method all the labelled components are obtained rapidly in one simple test procedure. The influence of various parameters such as gel type, column size, prehistory of column, equilibration, eluent, elution volume and flow rate upon the results have been investigated. Test results for sup(99 m)Tc-MDP have been compared for several different GCS systems, a few TLC systems and column chromatography with fraction collection. The GCS technique, optimized for testing sup(99m)Tc-MDP preparations has been applied in a few experiments in which very good reproducibility is required: Labelling kinetics and stability when stored at room temperature or in a refrigerator and influence of the sup(99m)Te/(sup(99m)Tc + /sup 99/Tc) atomic ratio and of the amount of radioactivity on the sup(99m)Tc-MDP labelling yield, covering parameter ranges of clinical interest, have been studied.

  3. Hybrid Instruments and the Indirect Credit Method - Does it work?

    OpenAIRE

    Wiedermann-Ondrej, Nadine

    2007-01-01

    This paper analyses the possibility of double non-taxation of hybrid instruments in cross border transactions where the country of the investor has implemented the indirect credit method for mitigation or elimination of double taxation. From an isolated perspective a double non-taxation cannot be obtained because typically no taxes are paid in the foreign country due to the classification as debt and therefore even in the case of a classification as a dividend in the country of the investor n...

  4. High performance liquid chromatography in pharmaceutical analyses

    Directory of Open Access Journals (Sweden)

    Branko Nikolin

    2004-05-01

    Full Text Available In testing the pre-sale procedure the marketing of drugs and their control in the last ten years, high performance liquid chromatographyreplaced numerous spectroscopic methods and gas chromatography in the quantitative and qualitative analysis. In the first period of HPLC application it was thought that it would become a complementary method of gas chromatography, however, today it has nearly completely replaced gas chromatography in pharmaceutical analysis. The application of the liquid mobile phase with the possibility of transformation of mobilized polarity during chromatography and all other modifications of mobile phase depending upon the characteristics of substance which are being tested, is a great advantage in the process of separation in comparison to other methods. The greater choice of stationary phase is the next factor which enables realization of good separation. The separation line is connected to specific and sensitive detector systems, spectrafluorimeter, diode detector, electrochemical detector as other hyphernated systems HPLC-MS and HPLC-NMR, are the basic elements on which is based such wide and effective application of the HPLC method. The purpose high performance liquid chromatography(HPLC analysis of any drugs is to confirm the identity of a drug and provide quantitative results and also to monitor the progress of the therapy of a disease.1 Measuring presented on the Fig. 1. is chromatogram obtained for the plasma of depressed patients 12 h before oral administration of dexamethasone. It may also be used to further our understanding of the normal and disease process in the human body trough biomedical and therapeutically research during investigation before of the drugs registration. The analyses of drugs and metabolites in biological fluids, particularly plasma, serum or urine is one of the most demanding but one of the most common uses of high performance of liquid chromatography. Blood, plasma or

  5. A novel liquid chromatography/mass spectrometry method for determination of neurotransmitters in brain tissue: Application to human tauopathies.

    Science.gov (United States)

    Forgacsova, Andrea; Galba, Jaroslav; Garruto, Ralph M; Majerova, Petra; Katina, Stanislav; Kovac, Andrej

    2018-01-15

    Neurotransmitters, small molecules widely distributed in the central nervous system are essential in transmitting electrical signals across neurons via chemical communication. Dysregulation of these chemical signaling molecules is linked to numerous neurological diseases including tauopathies. In this study, a precise and reliable liquid chromatography method was established with tandem mass spectrometry detection for the simultaneous determination of aspartic acid, asparagine, glutamic acid, glutamine, γ-aminobutyric acid, N-acetyl-l-aspartic acid, pyroglutamic acid, acetylcholine and choline in human brain tissue. The method was successfully applied to the analysis of human brain tissues from three different tauopathies; corticobasal degeneration, progressive supranuclear palsy and parkinsonism-dementia complex of Guam. Neurotransmitters were analyzed on ultra-high performance chromatography (UHPLC) using an ethylene bridged hybrid amide column coupled with tandem mass spectrometry (MS/MS). Identification and quantification of neurotransmitters was carried out by ESI+ mass spectrometry detection. We optimized sample preparation to achieve simple and fast extraction of all nine analytes. Our method exhibited an excellent linearity for all analytes (all coefficients of determination >0.99), with inter-day and intra-day precision yielding relative standard deviations 3.2%-11.2% and an accuracy was in range of 92.6%-104.3%. The present study, using the above method, is the first to demonstrate significant alterations of brain neurotransmitters caused by pathological processes in the brain tissues of patient with three different tauopathies. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Ionic liquid stationary phases for gas chromatography.

    Science.gov (United States)

    Poole, Colin F; Poole, Salwa K

    2011-04-01

    This article provides a summary of the development of ionic liquids as stationary phases for gas chromatography beginning with early work on packed columns that established details of the retention mechanism and established working methods to characterize selectivity differences compared with molecular stationary phases through the modern development of multi-centered cation and cross-linked ionic liquids for high-temperature applications in capillary gas chromatography. Since there are many reviews on ionic liquids dealing with all aspects of their chemical and physical properties, the emphasis in this article is placed on the role of gas chromatography played in the design of ionic liquids of low melting point, high thermal stability, high viscosity, and variable selectivity for separations. Ionic liquids provide unprecedented opportunities for extending the selectivity range and temperature-operating range of columns for gas chromatography, an area of separation science that has otherwise been almost stagnant for over a decade. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Atmospheric pressure photoionisation : An ionization method for liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Robb, DB; Covey, TR; Bruins, AP

    2000-01-01

    Atmospheric pressure photoionization (APPI) has been successfully demonstrated to provide high sensitivity to LC-MS analysis. A vacuum-ultraviolet lamp designed for photoionization detection in gas chromatography is used as a source of 10-eV photons. The mixture of samples and solvent eluting from

  8. METHOD 544. DETERMINATION OF MICROCYSTINS AND NODULARIN IN DRINKING WATER BY SOLID PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY (LC/MS/MS)

    Science.gov (United States)

    Method 544 is an accurate and precise analytical method to determine six microcystins (including MC-LR) and nodularin in drinking water using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC/MS/MS). The advantage of this SPE-LC/MS/MS is its sensi...

  9. Simultaneous determination of niacin and pyridoxine at trace levels by using diode array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry.

    Science.gov (United States)

    Sel, Sabriye; Öztürk Er, Elif; Bakırdere, Sezgin

    2017-12-01

    A highly sensitive and simple diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method was developed for the simultaneous determination of niacin and pyridoxine in pharmaceutical drugs, tap water, and wastewater samples. To determine the in vivo behavior of niacin and pyridoxine, analytes were subjected to simulated gastric conditions. The calibration plots of the diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method showed good linearity over a wide concentration range with close to 1.0 correlation coefficients for both analytes. The limit of detection/limit of quantitation values for liquid chromatography quadrupole time-of-flight tandem mass spectrometry analysis were 1.98/6.59 and 1.3/4.4 μg/L for niacin and pyridoxine, respectively, while limit of detection/limit of quantitation values for niacin and pyridoxine in high-performance liquid chromatography analysis were 3.7/12.3 and 5.7/18.9 μg/L, respectively. Recovery studies were also performed to show the applicability of the developed methods, and percentage recovery values were found to be 90-105% in tap water and 94-97% in wastewater for both analytes. The method was also successfully applied for the qualitative and quantitative determination of niacin and pyridoxine in drug samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Stationary phases for superheated water chromatography

    International Nuclear Information System (INIS)

    Saha, Shikha

    2002-01-01

    This project focused on the comparison of conventional liquid chromatography and superheated water chromatography. It examined the differences in efficiency and retention of a range of different stationary phases. Alkyl aryl ketones and eight aromatic compounds were separated on PBD-zirconia, Xterra RP 18, Luna C 18 (2) and Oasis HLB columns using conventional LC and superheated water chromatography system. The retention indices were determined in the different eluents. On changing the organic component of the eluent from methanol to acetonitrile to superheated water considerable improvements were found in the peak shapes and column efficiencies on the PBD-zirconia and Oasis HLB columns. PS-DVB, PBD-zirconia and Xterra RP 18 columns have been used in efficiency studies. It was found that simply elevating the column temperature did not increase the efficiency of a separation in superheated water chromatography. The efficiency depended on flow rate, injection volume and also mobile phase preheating system. Although high efficiencies were not achieved with superheated water on PS-DVB and Xterra RP 18 columns, a higher efficiency was achieved on a PBD-zirconia column with superheated water than with 25-35% ACN at room temperature. The proposed theoretical increases in u opt were measured on three columns using superheated water as the mobile phase. The application of the superheated water chromatographic method to the separation of the pungent constituents of ginger by superheated water chromatography-NMR coupling system was studied. The coupling of superheated water chromatography using deuterium oxide to NMR spectroscopy for the separation of dry ginger extract was successful, although the NMR sensitivity in on-line mode coupling system was low. However, four compounds were identified in the ginger extract by stop-flow mode on superheated water chromatography-UV-NMR detection system. (author)

  11. Development and validation of High-performance Thin-layer Chromatography Method for Simultaneous Determination of Polyphenolic Compounds in Medicinal Plants.

    Science.gov (United States)

    Jayachandran Nair, C V; Ahamad, Sayeed; Khan, Washim; Anjum, Varisha; Mathur, Rajani

    2017-12-01

    Quantitative standardization of plant-based products is challenging albeit essential to maintain their quality. This study aims to develop and validate high-performance thin-layer chromatography (HPTLC) method for the simultaneous determination of rutin (Ru), quercetin (Qu), and gallic acid (Ga) from Psidium guajava Linn. (PG) and Aegle marmelos (L.) Correa. (AM) and correlate with antioxidant activity. The stock solution (1 mg/mL) of standard Ru, Qu, and Ga in methanol: Water (1:1) was serially diluted and spotted (5 μL) on slica gel 60 F 254 thin-layer chromatography plates. Toluene: Ethyl acetate: Formic acid: Methanol (3:4:0.8:0.7, v/v/v) was selected as mobile phase for analysis at 254 nm. Hydroalcoholic (1:1) extracts of leaves of PG and AM were fractionated and similarly analyzed. Antioxidant activity was also determined using 2, 2-diphenyl-1-picrylhydrazyl assay. The developed method was robust and resolved Ru, Qu, and Ga at R f 0.08 ± 0.02, 0.76 ± 0.01, and 0.63 ± 0.02, respectively. The intra-day, interday precision, and interanalyst were limit of detection and limit of quantification for Ru, Qu, and Ga were 4.51, 4.2, 5.27, and 13.67, 12.73, 15.98 ng/spot, respectively. Antioxidant activity (Log 50% inhibition) of PG and AM was 4.947 ± 0.322 and 6.498 ± 0.295, respectively. The developed HPTLC method was rapid, accurate, precise, reproducible, and specific for the simultaneous estimation of Ru, Qu, and Ga. HPTLC method for simultaneous determination and quantification of Rutin, Quercetin and Gallic acid, is reported for quality control of herbal drugs. Abbreviations Used: A: Aqueous fraction; AM: Aegle marmelos L. Correa; B: Butanol fraction; C: Chloroform fraction; EA: Ethyl acetate fraction; Ga: Gallic acid; H: Hexane fraction; HA: Hydroalcoholic extract; HPTLC: High-performance thin-layer chromatography; PG: Psidium guajava ; Qu: Quercetin; Ru: Rutin.

  12. Separation Of N-Nitrosamines By Micellar Electrokinetic Chromatography

    International Nuclear Information System (INIS)

    Nur Amira Md Ali; Mohd Marsin Sanagi; Wan Aini Wan Ibrahim

    2014-01-01

    A simple and rapid micellar electrokinetic chromatography (MEKC) method was developed for separation of three selected N-Nitrosamines namely N-nitrosodipropylamine (NDPA), N-nitrosodibutylamine (NDBA) and N-nitrosodiphenylamine (NDPhA). The effects of composition of the buffer and its pH, concentration of surfactants on the separation and migration times of nitrosamines were investigated. The instrumental variables affecting sensitivity and resolution such as power supply and injection mode were carefully optimized. The best separation was achieved using 40 mM sodium dodecyl sulfate (SDS) as a surfactant in 10 mM phosphate buffer (pH 8.0) at a temperature of 25 degree Celsius, applied voltage of 29 kV, wavelength of 230 nm and electrokinetic injection of 9 s at 5 kV within 10 min analysis time. Excellent linearity was obtained in the concentration range of 2 to 100 μg/ mL with coefficients of determination, r 2 ≥0.979. This method showed good reproducibility with relative standard deviation (RSDs) value ranging from 2.46 % to 6.61 %. The limits of detection (LOD) and limits of quantification (LOQ) ranged from 0.16 to 0.43 μg/ mL and 0.54 to 1.44 μg/mL respectively. (author)

  13. Alternatives to Chromatography in Plant Breeding

    Directory of Open Access Journals (Sweden)

    Keusgen, Michael

    2016-07-01

    Full Text Available Wild plants were taken into cultivation because of special features. Usually, medicinal plants or spices show distinct secondary metabolites combined with a specific pattern of these compounds. Typically, chromatographic methods like gas chromatography (GC or high performance liquid chromatography (HPLC were applied as standard methods for a meaningful analysis of secondary metabolites. However, these methods are labor and time intensive. In the breeding process, usually numerous single plants have to be analyzed and therefore, high throughput methods are required. In this article, some examples for alternative strategies are given. Besides spectroscopic methods like near infrared (NIR, also biosensoric approaches should be considered. For instance, several enzymes can oxidize or hydrolyze secondary metabolites in dependence of their functional groups. Polyphenols can be determined by laccases. Polyphenols like catechins and flavonoids contribute to the bioactivity of many medicinal plants. Also cysteine sulfoxides, which are typical for Allium species like garlic and onions, can be enzymatically determined with high specificity. Finally, toxic cyanogenic glycosides can be quantified by the enzyme cyanidase.

  14. Radioanalytical determination of plutonium and americium using ion exchange and extraction chromatography technique in urine

    International Nuclear Information System (INIS)

    Santhanakrishnan, V.; Sreedevi, K.R.; Rajaram, S.; Ravi, P.M.

    2011-01-01

    The use of anion exchange chromatography for the separation of Pu and extraction chromatography technique for the separation of Am from urine samples was studied. In the earlier method, Pu separation was carried out by anion exchange chromatography followed by Am separation by cation exchange chromatography. The chemical recovery of Am obtained by cation exchange separation method was inconsistent and low in the range 30-70%. In this study, the average Pu recovery obtained using anion exchange chromatography was 89.2 with standard deviation of 10.4 and the average Am recovery obtained using extraction chromatography with TRU resin was 77.4 with standard deviation of 14.8. Moreover, Am separation could be completed within three hours using the TRU column compared to two days that were required for the cation exchange chromatography. (author)

  15. Gas Phase Chromatography of some Group 4, 5, and 6 Halides

    Energy Technology Data Exchange (ETDEWEB)

    Sylwester, Eric Robert [Univ. of California, Berkeley, CA (United States)

    1998-10-01

    Gas phase chromatography using The Heavy Element Volatility Instrument (HEVI) and the On Line Gas Apparatus (OLGA III) was used to determine volatilities of ZrBr4, HfBr4, RfBr4, NbBr5, TaOBr3, HaCl5, WBr6, FrBr, and BiBr3. Short-lived isotopes of Zr, Hf, Rf, Nb, Ta, Ha, W, and Bi were produced via compound nucleus reactions at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory and transported to the experimental apparatus using a He gas transport system. The isotopes were halogenated, separated from the other reaction products, and their volatilities determined by isothermal gas phase chromatography. Adsorption Enthalpy (ΔHa) values for these compounds were calculated using a Monte Carlo simulation program modeling the gas phase chromatography column. All bromides showed lower volatility than molecules of similar molecular structures formed as chlorides, but followed similar trends by central element. Tantalum was observed to form the oxybromide, analogous to the formation of the oxychloride under the same conditions. For the group 4 elements, the following order in volatility and ΔHa was observed: RfBr4 > ZrBr4 > HfBr4. The ΔHa values determined for the group 4, 5, and 6 halides are in general agreement with other experimental data and theoretical predictions. Preliminary experiments were performed on Me-bromides. A new measurement of the half-life of 261Rf was performed. 261Rf was produced via the 248Cm(18O, 5n) reaction and observed with a half-life of 74-6+7 seconds, in excellent agreement with the previous measurement of 78-6+11 seconds. We recommend a new half-life of 75±7 seconds for 261Rf based on these two measurements. Preliminary studies in transforming HEVI from an isothermal (constant

  16. Affinity monolith chromatography: A review of principles and recent analytical applications

    Science.gov (United States)

    Pfaunmiller, Erika L.; Paulemond, Marie Laura; Dupper, Courtney M.; Hage, David S.

    2012-01-01

    Affinity monolith chromatography (AMC) is a type of liquid chromatography that uses a monolithic support and a biologically-related binding agent as a stationary phase. AMC is a powerful method for the selective separation, analysis or studies of specific target compounds in a sample. This review discusses the basic principles of AMC and recent developments or applications of this method, with particular emphasis being given to work that has appeared in the last five years. Various materials that have been used to prepare columns for AMC are examined, including organic monoliths, silica monoliths, agarose monoliths and cryogels. These supports have been used in AMC for formats that have ranged from traditional columns to disks, microcolumns and capillaries. Many binding agents have also been employed in AMC, such as antibodies, enzymes, proteins, lectins, immobilized metal-ions and dyes. Some applications that have been reported with these binding agents in AMC are bioaffinity chromatography, immunoaffinity chromatography or immunoextraction, immobilized metal-ion affinity chromatography, dye-ligand affinity chromatography, chiral separations and biointeraction studies. Examples are presented from fields that include analytical chemistry, pharmaceutical analysis, clinical testing and biotechnology. Current trends and possible future directions in AMC are also discussed. PMID:23187827

  17. Core-shell in liquid chromatography: application for determining sulphonamides in feed and meat using conventional chromatographic systems

    Directory of Open Access Journals (Sweden)

    Antonio Armentano

    2016-12-01

    Full Text Available A C18 column packed with core-shell particles was used for the chromatographic separation of sulphonamides in feed and meat by a conventional high performance liquid chromatography system coupled with a diode array detector. Two analytical methods, already used in our laboratory, have been modified without any changes in the extraction and clean-up steps and in the liquid chromatography instrumentation. Chromatographic conditions applied on a traditional 5-μm column have been optimized on a column packed with 2.6 μm core-shell particles. A binary mobile phase [acetate buffer solution at pH 4.50 and a mixture of methanol acetonitrile 50: 50 (v/v] was employed in gradient mode at the flow rate of 1.2 mL with an injection volume of 6 μL. These chromatographic conditions allow the separation of 13 sulphonamides with an entire run of 13 minutes. Preliminary studies have been carried out comparing blanks and spiked samples of feed and meat. A good resolution and the absence of interferences were achieved in chromatograms for both matrices. Since no change was made to the sample preparation, the optimized method does not require a complete revalidation and can be used to make routine analysis faster.

  18. Development of a Method for Rapid Determination of Morpholine in Juices and Drugs by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Mengsi Cao

    2018-01-01

    Full Text Available A reliable derivatization method has been developed to detect and quantify morpholine in apple juices and ibuprofen with gas chromatography-mass spectrometry. Morpholine can react with sodium nitrite under acidic condition to produce stable and volatile N-nitrosomorpholine derivative. In this experiment, various factors affecting the derivatization and extraction process were optimized, including volume and concentration of hydrochloric acid, quantity of sodium nitrite, derivatization temperature, derivatization time, extraction reagents, and extraction time. The derivative was extracted with dichloromethane and determined by gas chromatography-mass spectrometry. The linearity range of morpholine was 10–500 μg·L−1 with good correlation, and limits of detection (LOD and limits of quantification (LOQ were 7.3 μg·L−1 and 24.4 μg·L−1, respectively. Low, medium, and high concentrations of morpholine were added in apple juices and ibuprofen samples to evaluate standard recovery rate and relative standard deviation. The spiked recovery rate ranged from 94.3% to 109.0%, and the intraday repeatability and interday reproducibility were 2.0%–4.4% and 3.3%–7.0%, respectively. The developed method has good accuracy and precision. This quantitative method for morpholine is simple, sensitive, rapid, and low cost and can successfully be applied to analyze the residual morpholine in apple juices and drug samples.

  19. High-performance liquid chromatography analysis methods developed for quantifying enzymatic esterification of flavonoids in ionic liquids.

    Science.gov (United States)

    Lue, Bena-Marie; Guo, Zheng; Xu, Xuebing

    2008-07-11

    Methods using reversed-phase high-performance liquid chromatography (RP-HPLC) with ELSD were investigated to quantify enzymatic reactions of flavonoids with fatty acids in the presence of diverse room temperature ionic liquids (RTILs). A buffered salt (preferably triethylamine-acetate) was found essential for separation of flavonoids from strongly polar RTILs, whereby RTILs were generally visible as two major peaks identified based on an ion-pairing/exchanging hypothesis. C8 and C12 stationary phases were optimal while mobile phase pH (3-7) had only a minor influence on separation. The method developed was successfully applied for primary screening of RTILs (>20), with in depth evaluation of substrates in 10 RTILs, for their evaluation as reaction media.

  20. Analytical method by high resolution liquid chromatography for the stability study of cloratidine syrup 0.1 %

    International Nuclear Information System (INIS)

    Torres Amaro, Leonid; Garcia Penna, Caridad M; Pardo Ruiz, Zenia

    2007-01-01

    A high resolution liquid chromatography method was validated to study the stability of cloratidine syrup 0.1 %. The calibration curve in the range from 13.6 to 3.36 μg/mL was lineal, with a coefficient of correlation equal to 0.99975. The intercept and slope statistical test was not significant. The recovery obtained was 100.2 % in the concentration range studied, and the Cochran and Student (t) tests results were not important. The variation coefficient in the repeatability study was equal to 0.41 % for 10 replications assayed, whereas in the reproducibility Fischer and Student tests were not remarkable. The method proved to be specific, lineal, accurate, and exact. (Author)

  1. Liquid chromatography/tandem mass spectrometry method for quantitative estimation of solutol HS15 and its applications

    OpenAIRE

    Bhaskar, V. Vijaya; Middha, Anil; Srivastava, Pratima; Rajagopal, Sriram

    2015-01-01

    A rapid, sensitive and selective pseudoMRM (pMRM)-based method for the determination of solutol HS15 (SHS15) in rat plasma was developed using liquid chromatography/tandem mass spectrometry (LCâMS/MS). The most abundant ions corresponding to SHS15 free polyethyleneglycol (PEG) oligomers at m/z 481, 525, 569, 613, 657, 701, 745, 789, 833, 877, 921 and 965 were selected for pMRM in electrospray mode of ionization. Purity of the lipophilic and hydrophilic components of SHS15 was estimated using ...

  2. Development of an analytical method coupling cell membrane chromatography with gas chromatography-mass spectrometry via microextraction by packed sorbent and its application in the screening of volatile active compounds in natural products.

    Science.gov (United States)

    Li, Miao; Wang, Sicen; He, Langchong

    2015-01-01

    Natural products (NPs) are important sources of lead compounds in modern drug discovery. To facilitate the screening of volatile active compounds in NPs, we have developed a new biochromatography method that uses rat vascular smooth muscle cells (VSMC), which are rich in L-type calcium channels (LCC), to prepare the stationary phase. This integrated method, which couples cell membrane chromatography (CMC) with gas chromatography-mass spectrometry (GC-MS) via microextraction by packed sorbent (MEPS) technology, has been termed VSMC/CMC-MEPS-GC-MS. Methodological validation confirmed its specificity, reliability and convenience. Screening results for Radix Angelicae Dahuricae and Fructus Cnidii obtained using VSMC/CMC-MEPS-GC-MS were consistent with those obtained using VSMC/CMC-offline-GC-MS. MEPS connection plays as simplified solid-phase extraction and replaces the uncontrollable evaporation operation in reported offline connections, so our new method is supposed to be more efficient and reliable than the offline ones, especially for compounds that are volatile, thermally unstable or difficult to purify. In application, senkyunolide A and ligustilide were preliminary identified as the volatile active components in Rhizoma Chuanxiong. We have thus confirmed the suitability of VSMC/CMC-MEPS-GC-MS for volatile active compounds screening in NP. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Core-Shell Columns in High-Performance Liquid Chromatography: Food Analysis Applications

    Science.gov (United States)

    Preti, Raffaella

    2016-01-01

    The increased separation efficiency provided by the new technology of column packed with core-shell particles in high-performance liquid chromatography (HPLC) has resulted in their widespread diffusion in several analytical fields: from pharmaceutical, biological, environmental, and toxicological. The present paper presents their most recent applications in food analysis. Their use has proved to be particularly advantageous for the determination of compounds at trace levels or when a large amount of samples must be analyzed fast using reliable and solvent-saving apparatus. The literature hereby described shows how the outstanding performances provided by core-shell particles column on a traditional HPLC instruments are comparable to those obtained with a costly UHPLC instrumentation, making this novel column a promising key tool in food analysis. PMID:27143972

  4. Comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones.

    Science.gov (United States)

    Carnes, Stephanie; O'Brien, Stacey; Szewczak, Angelica; Tremeau-Cayel, Lauriane; Rowe, Walter F; McCord, Bruce; Lurie, Ira S

    2017-09-01

    A comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones has been conducted. Nine different mixtures of bath salts were analyzed in this study. The three different chromatographic techniques were examined using a general set of controlled synthetic cathinones as well as a variety of other synthetic cathinones that exist as positional isomers. Overall 35 different synthetic cathinones were analyzed. A variety of column types and chromatographic modes were examined for developing each separation. For the ultra high performance supercritical fluid chromatography separations, analyses were performed using a series of Torus and Trefoil columns with either ammonium formate or ammonium hydroxide as additives, and methanol, ethanol or isopropanol organic solvents as modifiers. Ultra high performance liquid chromatographic separations were performed in both reversed phase and hydrophilic interaction chromatographic modes using SPP C18 and SPP HILIC columns. Gas chromatography separations were performed using an Elite-5MS capillary column. The orthogonality of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography was examined using principal component analysis. For the best overall separation of synthetic cathinones, the use of ultra high performance supercritical fluid chromatography in combination with gas chromatography is recommended. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Ion-Exchange Membrane Chromatography as an Alternative Method of Separation of Potato y Virus

    Directory of Open Access Journals (Sweden)

    Treder Krzysztof

    2015-12-01

    Full Text Available Procedures of separation of virus particles from a plant material are multistage. Furthermore often they are difficult in terms of methodology and require use of expensive, highly specialist equipment and yield of separation is often low. The antigen obtained is often degraded and contains admixtures of other proteins. Therefore, generation of high quality and specificity antibodies based on such antigen is very difficult and quality of the antibodies has impact on reliability, sensitivity and unambiguity of results of immunodiagnostic tests (e.g. ELISA that are currently conventionally used to detect vegetable viruses. In this study three conventionally-performed methods of separation of potato virus Y (PVY were compared and a method of separation based on membrane chromatography, as an alternative separation technique, has been presented. It has been demonstrated that in proper process conditions good quality virus preparation can be obtained.

  6. Developments in FT-ICR MS instrumentation, ionization techniques, and data interpretation methods for petroleomics.

    Science.gov (United States)

    Cho, Yunju; Ahmed, Arif; Islam, Annana; Kim, Sunghwan

    2015-01-01

    Because of the increasing importance of heavy and unconventional crude oil as an energy source, there is a growing need for petroleomics: the pursuit of more complete and detailed knowledge of the chemical compositions of crude oil. Crude oil has an extremely complex nature; hence, techniques with ultra-high resolving capabilities, such as Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), are necessary. FT-ICR MS has been successfully applied to the study of heavy and unconventional crude oils such as bitumen and shale oil. However, the analysis of crude oil with FT-ICR MS is not trivial, and it has pushed analysis to the limits of instrumental and methodological capabilities. For example, high-resolution mass spectra of crude oils may contain over 100,000 peaks that require interpretation. To visualize large data sets more effectively, data processing methods such as Kendrick mass defect analysis and statistical analyses have been developed. The successful application of FT-ICR MS to the study of crude oil has been critically dependent on key developments in FT-ICR MS instrumentation and data processing methods. This review offers an introduction to the basic principles, FT-ICR MS instrumentation development, ionization techniques, and data interpretation methods for petroleomics and is intended for readers having no prior experience in this field of study. © 2014 Wiley Periodicals, Inc.

  7. Detection methods for mycotoxins in cereal grains and cereal products

    Directory of Open Access Journals (Sweden)

    Pascale Michelangelo N.

    2009-01-01

    Full Text Available Analytical methods for mycotoxins in cereals and cereal-based products require three major steps, including extraction, clean-up (to eliminate interferences from the extract and concentrate the analyte, and detection/determination of the toxin (by using suitable analytical instruments/technologies. Clean-up is essential for the analysis of mycotoxins at trace levels, and involves the use of solid phase extraction and multifunctional (e.g. MycoSep® or immunoaffinity columns. Different chromatographic methods are commonly used for quantitative determination of mycotoxins, including gas-chromatography (GC coupled with electron capture, flame ionization or mass spectrometry (MS detectors (mainly for type-A trichothecenes, and high-performance liquid chromatography (HPLC coupled with ultraviolet, diode array, fluorescence or MS detectors. The choice of method depends on the matrix and the mycotoxin to be analyzed. Liquid chromatography-tandem mass spectrometry (LC-MS/MS is spreading rapidly as a promising technique for simultaneous screening, identification and quantitative determination of a large number of mycotoxins. In addition, commercial immunometric assays, such as enzyme-linked immunosorbent assays (ELISA, are frequently used for screening purposes as well. Recently, a variety of emerging methods have been proposed for the analysis of mycotoxins in cereals based on novel technologies, including immunochromatography (i.e. lateral flow devices, fluorescence polarization immunoassays (FPIA, infrared spectroscopy (FT-NIR, molecularly imprinted polymers (MIPs and optical biosensors.

  8. Instrumentation for environmental monitoring: biomedical

    International Nuclear Information System (INIS)

    1979-05-01

    An update is presented to Volume four of the six-volume series devoted to a survey of instruments useful for measurements in biomedicine related to environmental research and monitoring. Results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Methods of detection and analysis of gaseous organic pollutants and metals, including Ni and As are presented. Instrument techniques and notes are included on atomic spectrometry and uv and visible absorption instrumentation

  9. Comprehensive two-dimensional liquid chromatography: Ion chromatography × reversed-phase liquid chromatography for separation of low-molar-mass organic acids

    NARCIS (Netherlands)

    Brudin, S.S.; Shellie, R.A.; Haddad, P.R.; Schoenmakers, P.J.

    2010-01-01

    In the work presented here a novel approach to comprehensive two-dimensional liquid chromatography is evaluated. Ion chromatography is chosen for the first-dimension separation and reversed-phase liquid chromatography is chosen for the second-dimension separation mode. The coupling of these modes is

  10. USAGE OF PICTOGRAMS TO INTRODUCE MUSICAL INSTRUMENTS TO EDUCABLE MENTALLY RETARDED CHILDREN AS AN ALTERNATIVE METHOD

    Directory of Open Access Journals (Sweden)

    Gunsu YILMA

    2014-01-01

    Full Text Available The purpose of this research is to examine and investigate the perception ability of musical instruments of educable mentally retarded children with the support of visual elements. The research is conducted for every children individually in a special education and rehabilitation centre. The problematic of this research is the level of perception ability of musical instruments with visual support on mild mentally retarded children. In this research, perception ability of defining pictograms by music is introduced as an alternative method. It is researched that how educable mentally retarded children perceive pictograms by music tools. In this case, it is aimed to introduce musical instruments to educable mentally retarded children by pictograms with music. The research is applied with a qualitative approach. Data were obtained with the recorder, then they were turned into texts and analyzed with content analysis method.

  11. Development of a high-performance liquid chromatography method for the determination of florfenicol in animal feedstuffs.

    Science.gov (United States)

    Yang, JinJing; Sun, GuiZhi; Qian, MingRong; Huang, LingLi; Ke, XianBing; Yang, Bo

    2017-11-15

    An effective thin layer chromatography (TLC) purification procedure coupled to high-performance liquid chromatography (HPLC) method was developed for the determination of florfenicol (FF) in pig, chicken and fish feedstuffs. The feedstuff samples were extracted with ethyl acetate, defatted with n-hexane saturated with acetonitrile, and further purified by TLC. The chromatographic separation was performed on a Waters Symmetry C 18 column using an isocratic procedure with acetonitrile-water (35:65, v/v) at 0.6mL/min. The ultraviolet (UV) detector was set at a wavelength of 225nm. The FF concentrations in feedstuff samples were quantified using a standard curve. Good linear correlations (y=159075x-15054, r>0.9999) were achieved within the concentration range of 0.05-200μg/mL. The recoveries of FF spiked at levels of 1, 100 and 1000μg/g ranged from 80.6% to 105.3% with the intra-day and inter-day relative standard deviation (RSD) less than 9.3%. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.02 and 0.06mg/kg for pig feedstuffs, 0.02 and 0.07mg/kg for chicken feedstuffs, and 0.02 and 0.05mg/kg for fish feedstuffs, respectively. This reliable, simple and cost-effective method could be applied to the routine monitoring of FF in animal feedstuffs. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Tracking-by-detection of surgical instruments in minimally invasive surgery via the convolutional neural network deep learning-based method.

    Science.gov (United States)

    Zhao, Zijian; Voros, Sandrine; Weng, Ying; Chang, Faliang; Li, Ruijian

    2017-12-01

    Worldwide propagation of minimally invasive surgeries (MIS) is hindered by their drawback of indirect observation and manipulation, while monitoring of surgical instruments moving in the operated body required by surgeons is a challenging problem. Tracking of surgical instruments by vision-based methods is quite lucrative, due to its flexible implementation via software-based control with no need to modify instruments or surgical workflow. A MIS instrument is conventionally split into a shaft and end-effector portions, while a 2D/3D tracking-by-detection framework is proposed, which performs the shaft tracking followed by the end-effector one. The former portion is described by line features via the RANSAC scheme, while the latter is depicted by special image features based on deep learning through a well-trained convolutional neural network. The method verification in 2D and 3D formulation is performed through the experiments on ex-vivo video sequences, while qualitative validation on in-vivo video sequences is obtained. The proposed method provides robust and accurate tracking, which is confirmed by the experimental results: its 3D performance in ex-vivo video sequences exceeds those of the available state-of -the-art methods. Moreover, the experiments on in-vivo sequences demonstrate that the proposed method can tackle the difficult condition of tracking with unknown camera parameters. Further refinements of the method will refer to the occlusion and multi-instrumental MIS applications.

  13. Study of comportment of trioctylphosphine oxide by coat slight chromatography

    International Nuclear Information System (INIS)

    Meddour, Laaldja; Azzouz Abdelkrim

    1996-04-01

    The synthesis and characterisation process of the extractant agent 'Trioctylphosphine oxide' (TOPO) are not very developped in the literature. However, in order to identify this agent (TOPO) in its synthesis process, we attempt several analysis methods. The coat slight chromatography proves the simple and accessible method, that explains the choice of this study. In the present work, we have analysed the TOPO by coat slight chromatography with the intention of finding a better solvent

  14. Validating a High Performance Liquid Chromatography-Ion Chromatography (HPLC-IC) Method with Conductivity Detection After Chemical Suppression for Water Fluoride Estimation.

    Science.gov (United States)

    Bondu, Joseph Dian; Selvakumar, R; Fleming, Jude Joseph

    2018-01-01

    A variety of methods, including the Ion Selective Electrode (ISE), have been used for estimation of fluoride levels in drinking water. But as these methods suffer many drawbacks, the newer method of IC has replaced many of these methods. The study aimed at (1) validating IC for estimation of fluoride levels in drinking water and (2) to assess drinking water fluoride levels of villages in and around Vellore district using IC. Forty nine paired drinking water samples were measured using ISE and IC method (Metrohm). Water samples from 165 randomly selected villages in and around Vellore district were collected for fluoride estimation over 1 year. Standardization of IC method showed good within run precision, linearity and coefficient of variance with correlation coefficient R 2  = 0.998. The limit of detection was 0.027 ppm and limit of quantification was 0.083 ppm. Among 165 villages, 46.1% of the villages recorded water fluoride levels >1.00 ppm from which 19.4% had levels ranging from 1 to 1.5 ppm, 10.9% had recorded levels 1.5-2 ppm and about 12.7% had levels of 2.0-3.0 ppm. Three percent of villages had more than 3.0 ppm fluoride in the water tested. Most (44.42%) of these villages belonged to Jolarpet taluk with moderate to high (0.86-3.56 ppm) water fluoride levels. Ion Chromatography method has been validated and is therefore a reliable method in assessment of fluoride levels in the drinking water. While the residents of Jolarpet taluk (Vellore distict) are found to be at a high risk of developing dental and skeletal fluorosis.

  15. Liquid chromatography method development and optimization for valsartan: pharmacokinetics of oral hydrogels in rabbits

    International Nuclear Information System (INIS)

    Sohail, M.; Minhas, M.U.

    2017-01-01

    A simple, rapid, precise, accurate high performance liquid chromatography method has been developed and subsequently validated for determination of valsartan in rabbit plasma. The method was developed employing mixture of mobile phase consisting of 0.02 M potassium dihydrogen phosphate buffer and acetonitrile (45:55), pH was adjusted to 2.7 using 50% orthophosphoric acid and pumped thorough chromatographic system at a flow rate of 1 ml/min. An isocratic elution mode was carried out at HPLC system (Agilent Technologies, 1200 series, USA) fitted with variable wavelength detector and data processing software ChemStation. For sample analysis, 20 mul sample was injected and eluate was monitored at 225nm wavelength. Pharmacokinetic evaluation was performed in rabbits after the oral administration of valsartan loaded PVA-co-poly(AA) hydrogels. The mean Cmax of valsartan was 408.439ng/ml, Tmax was 12h and half life (t1/2) was 8.812h. The extraction procedure was simple with good response even at very low drug concentration, thereby making this method suitable for pharmacokinetic application. It is concluded that developed method is simple, fast, cost effective, and reproducible for the analysis of pharmacokinetic parameters in the rabbit plasma. (author)

  16. Flow Rates in Liquid Chromatography, Gas Chromatography and Supercritical Fluid Chromatography: A Tool for Optimization

    Directory of Open Access Journals (Sweden)

    Joris Meurs

    2016-08-01

    Full Text Available This paper aimed to develop a standalone application for optimizing flow rates in liquid chromatography (LC, gas chromatography (GC and supercritical fluid chromatography (SFC. To do so, Van Deemter’s equation, Knox’ equation and Golay’s equation were implemented in a MATLAB script and subsequently a graphical user interface (GUI was created. The application will show the optimal flow rate or linear velocity and the corresponding plate height for the set input parameters. Furthermore, a plot will be shown in which the plate height is plotted against the linear flow velocity. Hence, this application will give optimized flow rates for any set conditions with minimal effort.

  17. THE REGULATION OF MONEY CIRCULATION ON THE BASIS OF USING METHODS AND INSTRUMENTS OF MONETARY POLICY

    OpenAIRE

    S. Mishchenko; S. Naumenkova

    2013-01-01

    In the article it was researched the instruments and mechanism of safeguarding stability of money market on the basis of implementing the optimal monetary policy regime. It was determined the main directions of appliance the monetary policy methods and instruments to guiding money market stability and it was also investigated the influence of transmission mechanism on providing the soundness of money circulations.

  18. Recent developments in comprehensive two-dimensional gas chromatography (GC X GC) I. Introduction and instrumental set-up

    NARCIS (Netherlands)

    Adahchour, M.; Beens, J.; Vreuls, R.J.J.; Brinkman, U.A.T.

    2006-01-01

    We review the literature on comprehensive two-dimensional gas chromatography (GC × GC), emphasizing developments in the period 2003-2005. The review opens with a general introduction, the principles of the technique and the set-up of GC × GC systems. It also discusses theoretical aspects, trends in

  19. Bayesian methods for meta-analysis of causal relationships estimated using genetic instrumental variables

    DEFF Research Database (Denmark)

    Burgess, Stephen; Thompson, Simon G; Thompson, Grahame

    2010-01-01

    Genetic markers can be used as instrumental variables, in an analogous way to randomization in a clinical trial, to estimate the causal relationship between a phenotype and an outcome variable. Our purpose is to extend the existing methods for such Mendelian randomization studies to the context o...

  20. Method development and validation for the determination of pesticides in green coffee by gas chromatography

    International Nuclear Information System (INIS)

    Dallos Corredor, David; Guerrero Dallos, Jairo Arturo

    2005-01-01

    This study describes the implementation and validation of a multiresidue methodology for the determination of organochlorine, organophosphorus and pyrethroids pesticides in green coffee. Pesticides residues were extracted from green samples with an acetone-water (2:1) mixture followed by ethyl acetate cyclohexane (1:1) partitioning. The clean up steps include gel permeation chromatography and mini column chromatography using silica gel. Final determination was carried out by high-resolution gas chromatography with a pulsed split less injection mode and simultaneous detection by μ-ECD and NPD coupled in parallel. The methodology is specific, selective precise and accurate. Recoveries of majority of pesticides from spiked samples range from 70 to 110% at fortification levels of 0.038 mg/kg-1.536 mg/kg with limit of quantitation between 0.011 mg/kg and 0.100 mg/kg

  1. Recent advances in the instrumental techniques for the analysis of modern materials (II)

    International Nuclear Information System (INIS)

    Ahmed, M.

    1990-01-01

    Inductively Coupled Plasma Mass Spectrometry ICP-MS a logical development of equally established sister technique of ICP-AEA discussed in part-1 of this series of article on modern analytical techniques. The rapid adaptation of argon plasma as ion source for time of flight quadrupole mass analyser has led to the development of truly integrated instrumental technique for analysis of solutions and slurries. The powerful combination with laser ablation device has made the direct analysis of geological, geochemical and other complex conducting and non conducting samples possible in days rather months at sub ppm levels. Parallel development in computer hardware and software has made the instrumental optimization easy enabling the generation of meaningful analytical data a matter of routine. The limitations imposed by spectroscopic and non restricted the variety of matrices and materials covered by ICP-MS of LA-ICP-MS. The technique has provided it formidable analytical power in wide areas of industrial environmental, social, biological and break through advanced materials used in space mass communication, transportation and general areas of advanced analytical chemistry. It is expected that in combination with other instrumental methods as HPLC, ETC, ion chromatography. ICP-MS shall continue to dominate well into the 21st century. (author)

  2. The compactness of front tracking for chromatography electrophoresis and incompressible multiphase flow

    International Nuclear Information System (INIS)

    Wendroff, B.

    1992-01-01

    An analysis of the equations of chromatography from the point of view of hyperbolic conservation laws has been reviewed in recent literature. Serre was able to prove that the Lax-Friedrichs difference scheme, Godunov's method, and the viscosity method, have a subsequence converging to a weak solution of the chromatography equations, with no restriction on the size of the initial data. The purpose of this note is to announce that two versions of front tracking can be added to this list. After a brief description of the properties of the chromatography system and a definition of front tracking we give the basic steps of the proof. An example showing the quality of a front tracking solution is given. The equations of idealized electrophoresis and multiphase incompressible flow are very similar to the chromatography equations, but the former have linearly degenerate characteristic field, creating contact discontinuities. In the final section we briefly indicate how our result for chromatography carries over to this case

  3. Development of a sample preparation method for the analysis of current-use pesticides in sediment using gas chromatography.

    Science.gov (United States)

    Wang, Dongli; Weston, Donald P; Ding, Yuping; Lydy, Michael J

    2010-02-01

    Pyrethroid insecticides have been implicated as the cause of sediment toxicity to Hyalella azteca in both agricultural and urban areas of California; however, for a subset of these toxic sediments (approximately 30%), the cause of toxicity remains unidentified. This article describes the analytical method development for seven additional pesticides that are being examined to determine if they might play a role in the unexplained toxicity. A pressurized liquid extraction method was optimized to simultaneously extract diazinon, methyl parathion, oxyfluorfen, dicofol, fenpropathrin, pyraclostrobin, and indoxacarb from sediment, and the extracts were cleaned using a two-step solid-phase extraction procedure. The final extract was analyzed for the target pesticides by gas chromatography/nitrogen-phosphorus detector (GC/NPD), and gas chromatography/electron capture detector (GC/ECD), after sulfur was removed by shaking with copper and cold crystallization. Three sediments were used as reference matrices to assess method accuracy and precision. Method detection limits were 0.23-1.8 ng/g dry sediment using seven replicates of sediment spiked at 1.0 ng/g dry sediment. Recoveries ranged from 61.6 to 118% with relative standard deviations of 2.1-17% when spiked at 5.0 and 50 ng/g dry sediment. The three reference sediments, spiked with 50 ng/g dry weight of the pesticide mixture, were aged for 0.25, 1, 4, 7, and 14 days. Recoveries of the pesticides in the sediments generally decreased with increased aging time, but the magnitude of the decline was pesticide and sediment dependent. The developed method was applied to field-collected sediments from the Central Valley of California.

  4. Emission quantification using the tracer gas dispersion method: The influence of instrument, tracer gas species and source simulation

    DEFF Research Database (Denmark)

    Delre, Antonio; Mønster, Jacob; Samuelsson, Jerker

    2018-01-01

    The tracer gas dispersion method (TDM) is a remote sensing method used for quantifying fugitive emissions by relying on the controlled release of a tracer gas at the source, combined with concentration measurements of the tracer and target gas plumes. The TDM was tested at a wastewater treatment...... plant for plant-integrated methane emission quantification, using four analytical instruments simultaneously and four different tracer gases. Measurements performed using a combination of an analytical instrument and a tracer gas, with a high ratio between the tracer gas release rate and instrument...... precision (a high release-precision ratio), resulted in well-defined plumes with a high signal-to-noise ratio and a high methane-to-tracer gas correlation factor. Measured methane emission rates differed by up to 18% from the mean value when measurements were performed using seven different instrument...

  5. Analysis of Fluconazole in Human Urine Sample by High Performance Liquid Chromatography Method

    International Nuclear Information System (INIS)

    Hermawan, D; Ali, N A Md; Ibrahim, W A Wan; Sanagi, M M

    2013-01-01

    A method for determination of fluconazole, antifungal drug in human urine by using reversed-phased high performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detector was developed. Optimization HPLC conditions were carried out by changing the flow rate and composition of mobile phase. The optimum separation conditions at a flow rate 0.85 mL/min with a composition of mobile phase containing methanol:water (70:30, v/v) with UV detection at a wavelength 254 nm was able to analyze fluconazole within 3 min. The excellent linearity was obtained in the range of concentration 1 to 10 μg/mL with r 2 = 0.998. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.39 μg/mL and 1.28 μg/mL, respectively. Solid phase extraction (SPE) method using octadecylsilane (C18) as a sorbent was used to clean-up and pre-concentrated of the urine sample prior to HPLC analysis. The average recoveries of fluconazole in spiked urine sample was 72.4% with RSD of 3.21% (n=3).

  6. Validation parameters of instrumental method for determination of total bacterial count in milk

    Directory of Open Access Journals (Sweden)

    Nataša Mikulec

    2004-10-01

    Full Text Available The method of flow citometry as rapid, instrumental and routine microbiological method is used for determination of total bacterial count in milk. The results of flow citometry are expressed as individual bacterial cells count. Problems regarding the interpretation of the results of total bacterial count can be avoided by transformation of the results of flow citometry method onto the scale of reference method (HRN ISO 6610:2001.. The method of flow citometry, like any analitycal method, according to the HRN EN ISO/IEC 17025:2000 standard, requires validation and verification. This paper describes parameters of validation: accuracy, precision, specificity, range, robustness and measuring uncertainty for the method of flow citometry.

  7. Determine equilibrium dissociation constant of drug-membrane receptor affinity using the cell membrane chromatography relative standard method.

    Science.gov (United States)

    Ma, Weina; Yang, Liu; Lv, Yanni; Fu, Jia; Zhang, Yanmin; He, Langchong

    2017-06-23

    The equilibrium dissociation constant (K D ) of drug-membrane receptor affinity is the basic parameter that reflects the strength of interaction. The cell membrane chromatography (CMC) method is an effective technique to study the characteristics of drug-membrane receptor affinity. In this study, the K D value of CMC relative standard method for the determination of drug-membrane receptor affinity was established to analyze the relative K D values of drugs binding to the membrane receptors (Epidermal growth factor receptor and angiotensin II receptor). The K D values obtained by the CMC relative standard method had a strong correlation with those obtained by the frontal analysis method. Additionally, the K D values obtained by CMC relative standard method correlated with pharmacological activity of the drug being evaluated. The CMC relative standard method is a convenient and effective method to evaluate drug-membrane receptor affinity. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Benefits and Limitations of Lab-on-a-Chip Method over Reversed-Phase High-Performance Liquid Chromatography Method in Gluten Proteins Evaluation

    Directory of Open Access Journals (Sweden)

    Dragan Živančev

    2015-01-01

    Full Text Available RP-HPLC (reversed-phase high-performance liquid chromatography is widely used to determine the amounts of the different gluten protein types. However, this method is time-consuming, especially at early stages of wheat breeding, when large number of samples needs to be analyzed. On the other hand, LoaC (Lab-on-a-Chip technique has the potential for a fast, reliable, and automatable analysis of proteins. In the present study, benefits and limitations of Lab-on-a-Chip method over RP-HPLC method in gluten proteins evaluation were explored in order to determine in which way LoaC method should be improved in order to make its results more compliant with the results of RP-HPLC method. Strong correlation (P≤0.001 was found between numbers of HMW glutenin peaks determined by LoaC and RP-HPLC methods. Significant correlations (P≤0.05 were obtained between percentages of HMW and LMW glutenin subunits calculated with regard to total HMW + LMW area. Even more significant correlation (P≤0.001 was found when percentages of individual HMW areas were calculated with regard to total HMW. RP-HPLC method showed superiority in determination of gliadins since larger number and better resolution of gliadin peaks were obtained by this method.

  9. Effect of kinetic properties of extraction systems on separation of some elements by liquid chromatography method with free fixed phase

    International Nuclear Information System (INIS)

    Fedotov, P.S.; Maryutina, T.A.; Pichugin, A.A.; Spivakov, B.Ya.

    1993-01-01

    Effect of kinetic properties of a series of extraction systems on the separation of certain elements by the method of liquid chromatography with free fixed phase is considered. Chromatographic behaviour of europium 3 and iron 3 ions when using systems based on di-2-ethylhexylphosphovers acid and tetraphenylmethylenediphosphine dioxide is investigated. Kinetic properties of the extraction systems used are studied by diffusion cell method with mixing, europium 3 and iron 3 mass transfer coefficients are determined

  10. Instrumentation

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.G.

    1982-01-01

    This chapter reviews the parameters which are important to positron-imaging instruments. It summarizes the options which various groups have explored in designing tomographs and the methods which have been developed to overcome some of the limitations inherent in the technique as well as in present instruments. The chapter is not presented as a defense of positron imaging versus single-photon or other imaging modality, neither does it contain a description of various existing instruments, but rather stresses their common properties and problems. Design parameters which are considered are resolution, sampling requirements, sensitivity, methods of eliminating scattered radiation, random coincidences and attenuation. The implementation of these parameters is considered, with special reference to sampling, choice of detector material, detector ring diameter and shielding and variations in point spread function. Quantitation problems discussed are normalization, and attenuation and random corrections. Present developments mentioned are noise reduction through time-of-flight-assisted tomography and signal to noise improvements through high intrinsic resolution. Extensive bibliography. (U.K.)

  11. Ambient measurements of aromatic and oxidized VOCs by PTR-MS and GC-MS: intercomparison between four instruments in a boreal forest in Finland

    Science.gov (United States)

    Kajos, M. K.; Rantala, P.; Hill, M.; Hellén, H.; Aalto, J.; Patokoski, J.; Taipale, R.; Hoerger, C. C.; Reimann, S.; Ruuskanen, T. M.; Rinne, J.; Petäjä, T.

    2015-10-01

    Proton transfer reaction mass spectrometry (PTR-MS) and gas chromatography mass spectrometry GC-MS) are commonly used methods for automated in situ measurements of various volatile organic compounds (VOCs) in the atmosphere. In order to investigate the reliability of such measurements, we operated four automated analyzers using their normal field measurement protocol side by side at a boreal forest site. We measured methanol, acetaldehyde, acetone, benzene and toluene by two PTR-MS and two GC-MS instruments. The measurements were conducted in southern Finland between 13 April and 14 May 2012. This paper presents correlations and biases between the concentrations measured using the four instruments. A very good correlation was found for benzene and acetone measurements between all instruments (the mean R value was 0.88 for both compounds), while for acetaldehyde and toluene the correlation was weaker (with a mean R value of 0.50 and 0.62, respectively). For some compounds, notably for methanol, there were considerable systematic differences in the mixing ratios measured by the different instruments, despite the very good correlation between the instruments (mean R = 0.90). The systematic difference manifests as a difference in the linear regression slope between measurements conducted between instruments, rather than as an offset. This mismatch indicates that the systematic uncertainty in the sensitivity of a given instrument can lead to an uncertainty of 50-100 % in the methanol emissions measured by commonly used methods.

  12. Validation of a high performance liquid chromatography method for quantitation of L-proline in 20 % tincture from Murraya paniculata L. Jack

    International Nuclear Information System (INIS)

    Varona Torres, Noel; Gutierrez Gaiten, Yamilet Irene; Casado Martin, Celia Magaly

    2014-01-01

    The search for analytical methods that may monitor the quality of drugs is an issue of great interest in the pharmaceutical field, even more if they are directed to studying chemical markers of medicinal plants, their extracts and phytomedicines. To validate a high-resolution liquid chromatography (HPLC) method for the quantitative determination of the L-proline amino acid as a marker substance in Murraya paniculata L. Jack tincture

  13. Development of a quality instrument for assessing the spontaneous reports of ADR/ADE using Delphi method in China.

    Science.gov (United States)

    Chen, Lixun; Jiang, Ling; Shen, Aizong; Wei, Wei

    2016-09-01

    The frequently low quality of submitted spontaneous reports is of an increasing concern; to our knowledge, no validated instrument exists for assessing case reports' quality comprehensively enough. This work was conducted to develop such a quality instrument for assessing the spontaneous reports of adverse drug reaction (ADR)/adverse drug event (ADE) in China. Initial evaluation indicators were generated using systematic and literature data analysis. Final indicators and their weights were identified using Delphi method. The final quality instrument was developed by adopting the synthetic scoring method. A consensus was reached after four rounds of Delphi survey. The developed quality instrument consisted of 6 first-rank indicators, 18 second-rank indicators, and 115 third-rank indicators, and each rank indicator has been weighted. It evaluates the quality of spontaneous reports of ADR/ADE comprehensively and quantitatively on six parameters: authenticity, duplication, regulatory, completeness, vigilance level, and reporting time frame. The developed instrument was tested with good reliability and validity, which can be used to comprehensively and quantitatively assess the submitted spontaneous reports of ADR/ADE in China.

  14. A high performance liquid chromatography method for determination of furfural in crude palm oil.

    Science.gov (United States)

    Loi, Chia Chun; Boo, Huey Chern; Mohammed, Abdulkarim Sabo; Ariffin, Abdul Azis

    2011-09-01

    A modified steam distillation method was developed to extract furfural from crude palm oil (CPO). The collected distillates were analysed using high performance liquid chromatography (HPLC) coupled with an ultraviolet diode detector at 284nm. The HPLC method allowed identification and quantification of furfural in CPO. The unique thermal extraction of CPO whereby the fresh fruit bunches (FFB) are first subjected to steam treatment, distinguishes itself from other solvent-extracted or cold-pressed vegetable oils. The presence of furfural was also determined in the fresh palm oil from FFB (without undergoing the normal extraction process), palm olein, palm stearin, olive oil, coconut oil, sunflower oil, soya oil and corn oil. The chromatograms of the extracts were compared to that of standard furfural. Furfural was only detected in CPO. The CPO consignments obtained from four mills were shown to contain 7.54 to 20.60mg/kg furfural. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. THE REGULATION OF MONEY CIRCULATION ON THE BASIS OF USING METHODS AND INSTRUMENTS OF MONETARY POLICY

    Directory of Open Access Journals (Sweden)

    S. Mishchenko

    2013-05-01

    Full Text Available In the article it was researched the instruments and mechanism of safeguarding stability of money market on the basis of implementing the optimal monetary policy regime. It was determined the main directions of appliance the monetary policy methods and instruments to guiding money market stability and it was also investigated the influence of transmission mechanism on providing the soundness of money circulations.

  16. Formic acid hydrolysis/liquid chromatography isotope dilution mass spectrometry: An accurate method for large DNA quantification.

    Science.gov (United States)

    Shibayama, Sachie; Fujii, Shin-Ichiro; Inagaki, Kazumi; Yamazaki, Taichi; Takatsu, Akiko

    2016-10-14

    Liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) with formic acid hydrolysis was established for the accurate quantification of λDNA. The over-decomposition of nucleobases in formic acid hydrolysis was restricted by optimizing the reaction temperature and the reaction time, and accurately corrected by using deoxynucleotides (dNMPs) and isotope-labeled dNMPs as the calibrator and the internal standard, respectively. The present method could quantify λDNA with an expanded uncertainty of 4.6% using 10fmol of λDNA. The analytical results obtained with the present method were validated by comparing with the results of phosphate-base quantification by inductively coupled plasma-mass spectrometry (ICP-MS). The results showed good agreement with each other. We conclude that the formic acid hydrolysis/LC-IDMS method can quantify λDNA accurately and is promising as the primary method for the certification of DNA as reference material. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Authentication method for safeguards instruments securing data transmission

    International Nuclear Information System (INIS)

    Richter, B.; Stein, G.; Neumann, G.; Gartner, K.J.

    1986-01-01

    Because of the worldwide increase in nuclear fuel cycle activities, the need arises to reduce inspection effort by increasing the inspection efficiency per facility. Therefore, more and more advanced safeguards instruments will be designed for automatic operation. In addition, sensoring and recording devices may be well separated from each other within the facility, while the data transmission medium is a cable. The basic problem is the authenticity of the transmitted information. It has to be ensured that no potential adversary is able to falsify the transmitted safeguards data, i.e. the data transmission is secured. At present, predominantly C/S-devices are designed for automatic and remote interrogation. Also in other areas of safeguards instrumentation authentication will become a major issue, in particular, where the facility operator may offer his process instrumentation to be used also for safeguards purposes. In this paper possibilities to solve the problem of authentication are analysed

  18. Liquid paraffin as new dilution medium for the analysis of high boiling point residual solvents with static headspace-gas chromatography.

    Science.gov (United States)

    D'Autry, Ward; Zheng, Chao; Bugalama, John; Wolfs, Kris; Hoogmartens, Jos; Adams, Erwin; Wang, Bochu; Van Schepdael, Ann

    2011-07-15

    Residual solvents are volatile organic compounds which can be present in pharmaceutical substances. A generic static headspace-gas chromatography analysis method for the identification and control of residual solvents is described in the European Pharmacopoeia. Although this method is proved to be suitable for the majority of samples and residual solvents, the method may lack sensitivity for high boiling point residual solvents such as N,N-dimethylformamide, N,N-dimethylacetamide, dimethyl sulfoxide and benzyl alcohol. In this study, liquid paraffin was investigated as new dilution medium for the analysis of these residual solvents. The headspace-gas chromatography method was developed and optimized taking the official Pharmacopoeia method as a starting point. The optimized method was validated according to ICH criteria. It was found that the detection limits were below 1μg/vial for each compound, indicating a drastically increased sensitivity compared to the Pharmacopoeia method, which failed to detect the compounds at their respective limit concentrations. Linearity was evaluated based on the R(2) values, which were above 0.997 for all compounds, and inspection of residual plots. Instrument and method precision were examined by calculating the relative standard deviations (RSD) of repeated analyses within the linearity and accuracy experiments, respectively. It was found that all RSD values were below 10%. Accuracy was checked by a recovery experiment at three different levels. Mean recovery values were all in the range 95-105%. Finally, the optimized method was applied to residual DMSO analysis in four different Kollicoat(®) sample batches. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Proceedings of a workshop on methods for neutron scattering instrumentation design

    International Nuclear Information System (INIS)

    Hjelm, R.P.

    1997-09-01

    The future of neutron and x-ray scattering instrument development and international cooperation was the focus of the workshop. The international gathering of about 50 participants representing 15 national facilities, universities and corporations featured oral presentations, posters, discussions and demonstrations. Participants looked at a number of issues concerning neutron scattering instruments and the tools used in instrument design. Objectives included: (1) determining the needs of the neutron scattering community in instrument design computer code and information sharing to aid future instrument development, (2) providing for a means of training scientists in neutron scattering and neutron instrument techniques, and (3) facilitating the involvement of other scientists in determining the characteristics of new instruments that meet future scientific objectives, and (4) fostering international cooperation in meeting these needs. The scope of the meeting included: (1) a review of x-ray scattering instrument design tools, (2) a look at the present status of neutron scattering instrument design tools and models of neutron optical elements, and (3) discussions of the present and future needs of the neutron scattering community. Selected papers were abstracted separately for inclusion to the Energy Science and Technology Database

  20. Proceedings of a workshop on methods for neutron scattering instrumentation design

    Energy Technology Data Exchange (ETDEWEB)

    Hjelm, R.P. [ed.] [Los Alamos National Lab., NM (United States)

    1997-09-01

    The future of neutron and x-ray scattering instrument development and international cooperation was the focus of the workshop. The international gathering of about 50 participants representing 15 national facilities, universities and corporations featured oral presentations, posters, discussions and demonstrations. Participants looked at a number of issues concerning neutron scattering instruments and the tools used in instrument design. Objectives included: (1) determining the needs of the neutron scattering community in instrument design computer code and information sharing to aid future instrument development, (2) providing for a means of training scientists in neutron scattering and neutron instrument techniques, and (3) facilitating the involvement of other scientists in determining the characteristics of new instruments that meet future scientific objectives, and (4) fostering international cooperation in meeting these needs. The scope of the meeting included: (1) a review of x-ray scattering instrument design tools, (2) a look at the present status of neutron scattering instrument design tools and models of neutron optical elements, and (3) discussions of the present and future needs of the neutron scattering community. Selected papers were abstracted separately for inclusion to the Energy Science and Technology Database.

  1. Forensic Drug Identification, Confirmation, and Quantification Using Fully Integrated Gas Chromatography with Fourier Transform Infrared and Mass Spectrometric Detection (GC-FT-IR-MS).

    Science.gov (United States)

    Lanzarotta, Adam; Lorenz, Lisa; Voelker, Sarah; Falconer, Travis M; Batson, JaCinta S

    2018-05-01

    This manuscript is a continuation of a recent study that described the use of fully integrated gas chromatography with direct deposition Fourier transform infrared detection and mass spectrometric detection (GC-FT-IR-MS) to identify and confirm the presence of sibutramine and AB-FUBINACA. The purpose of the current study was to employ the GC-FT-IR portion of the same instrument to quantify these compounds, thereby demonstrating the ability to identify, confirm, and quantify drug substances using a single GC-FT-IR-MS unit. The performance of the instrument was evaluated by comparing quantitative analytical figures of merit to those measured using an established, widely employed method for quantifying drug substances, high performance liquid chromatography with ultraviolet detection (HPLC-UV). The results demonstrated that GC-FT-IR was outperformed by HPLC-UV with regard to sensitivity, precision, and linear dynamic range (LDR). However, sibutramine and AB-FUBINACA concentrations measured using GC-FT-IR were not significantly different at the 95% confidence interval compared to those measured using HPLC-UV, which demonstrates promise for using GC-FT-IR as a semi-quantitative tool at the very least. The most significant advantage of GC-FT-IR compared to HPLC-UV is selectivity; a higher level of confidence regarding the identity of the analyte being quantified is achieved using GC-FT-IR. Additional advantages of using a single GC-FT-IR-MS instrument for identification, confirmation, and quantification are efficiency, increased sample throughput, decreased consumption of laboratory resources (solvents, chemicals, consumables, etc.), and thus cost.

  2. Multi-residue analysis method for analysis of pharmaceuticals using liquid chromatography-time of flight/mass spectrometry (LC-TOF/MS) in water sample

    Science.gov (United States)

    Al-Qaim, Fouad Fadhil; Abdullah, Md Pauzi; Othman, Mohamed Rozali

    2013-11-01

    In this work, a developed method using solid - phase extraction (SPE) followed by liquid chromatography - time of flight mass spectrometry (LC-ESI-TOF/MS) was developed and validated for quantification and confirmation of eleven pharmaceuticals with different therapeutic classes in water samples, Malaysia. These compounds are caffeine (CAF), prazosin (PRZ), enalapril (ENL), carbamazepine (CBZ), nifedipine (NFD), levonorgestrel (LNG), simvastatin (SMV), hydrochlorothiazide (HYD), gliclazide (GLIC), diclofenac-Na (DIC-Na) and mefenamic acid (MEF). LC was performed on a Dionex Ultimate 3000/LC 09115047 (USA) system. Chromatography was performed on a Thermo Scientific C18 (250 mm × 2.1 mm, i.d.: 5μm) column. Several parameters were optimised such as; mobile phase, gradient elution, collision energy and solvent elution for extraction of compounds from water. The recoveries obtained ranged from 30-148 % in river water. Five pharmaceutical compounds were detected in the surface water samples: caffeine, prazosin, enalpril, diclofenac-Na and mefenamic acid. The developed method is precise and accepted recoveries were got. In addition, this method is suitable to identify and quantify trace concentrations of pharmaceuticals in surface water.

  3. Bacterial Cell Wall Precursor Phosphatase Assays Using Thin-layer Chromatography (TLC) and High Pressure Liquid Chromatography (HPLC).

    Science.gov (United States)

    Pazos, Manuel; Otten, Christian; Vollmer, Waldemar

    2018-03-20

    Peptidoglycan encases the bacterial cytoplasmic membrane to protect the cell from lysis due to the turgor. The final steps of peptidoglycan synthesis require a membrane-anchored substrate called lipid II, in which the peptidoglycan subunit is linked to the carrier lipid undecaprenol via a pyrophosphate moiety. Lipid II is the target of glycopeptide antibiotics and several antimicrobial peptides, and is degraded by 'attacking' enzymes involved in bacterial competition to induce lysis. Here we describe two protocols using thin-layer chromatography (TLC) and high pressure liquid chromatography (HPLC), respectively, to assay the digestion of lipid II by phosphatases such as Colicin M or the LXG toxin protein TelC from Streptococcus intermedius . The TLC method can also monitor the digestion of undecaprenyl (pyro)phosphate, whereas the HPLC method allows to separate the di-, mono- or unphosphorylated disaccharide pentapeptide products of lipid II.

  4. High-performance liquid chromatography method validation for determination of tetracycline residues in poultry meat

    Directory of Open Access Journals (Sweden)

    Vikas Gupta

    2014-01-01

    Full Text Available Background: In this study, a method for determination of tetracycline (TC residues in poultry with the help of high-performance liquid chromatography technique was validated. Materials and Methods: The principle step involved in ultrasonic-assisted extraction of TCs from poultry samples by 2 ml of 20% trichloroacetic acid and phosphate buffer (pH 4, which gave a clearer supernatant and high recovery, followed by centrifugation and purification by using 0.22 μm filter paper. Results: Validity study of the method revealed that all obtained calibration curves showed good linearity (r2 > 0.999 over the range of 40-4500 ng. Sensitivity was found to be 1.54 and 1.80 ng for oxytetracycline (OTC and TC. Accuracy was in the range of 87.94-96.20% and 72.40-79.84% for meat. Precision was lower than 10% in all cases indicating that the method can be used as a validated method. Limit of detection was found to be 4.8 and 5.10 ng for OTC and TC, respectively. The corresponding values of limit of quantitation were 11 and 12 ng. Conclusion: The method reliably identifies and quantifies the selected TC and OTC in the reconstituted poultry meat in the low and sub-nanogram range and can be applied in any laboratory.

  5. Rapid quantitative analysis of individual anthocyanin content based on high-performance liquid chromatography with diode array detection with the pH differential method.

    Science.gov (United States)

    Wang, Huayin

    2014-09-01

    A new quantitative technique for the simultaneous quantification of the individual anthocyanins based on the pH differential method and high-performance liquid chromatography with diode array detection is proposed in this paper. The six individual anthocyanins (cyanidin 3-glucoside, cyanidin 3-rutinoside, petunidin 3-glucoside, petunidin 3-rutinoside, and malvidin 3-rutinoside) from mulberry (Morus rubra) and Liriope platyphylla were used for demonstration and validation. The elution of anthocyanins was performed using a C18 column with stepwise gradient elution and individual anthocyanins were identified by high-performance liquid chromatography with tandem mass spectrometry. Based on the pH differential method, the high-performance liquid chromatography peak areas of maximum and reference absorption wavelengths of anthocyanin extracts were conducted to quantify individual anthocyanins. The calibration curves for these anthocyanins were linear within the range of 10-5500 mg/L. The correlation coefficients (r(2)) all exceeded 0.9972, and the limits of detection were in the range of 1-4 mg/L at a signal-to-noise ratio ≥5 for these anthocyanins. The proposed quantitative analysis was reproducible with good accuracy of all individual anthocyanins ranging from 96.3 to 104.2% and relative recoveries were in the range 98.4-103.2%. The proposed technique is performed without anthocyanin standards and is a simple, rapid, accurate, and economical method to determine individual anthocyanin contents. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Comprehensive measurement of total nondigestible carbohydrates in foods by enzymatic-gravimetric method and liquid chromatography.

    Science.gov (United States)

    Nishibata, Toyohide; Tashiro, Kouichi; Kanahori, Sumiko; Hashizume, Chieko; Kitagawa, Machiko; Okuma, Kazuhiro; Gordon, Dennis T

    2009-09-09

    Total nondigestible carbohydrate (NDC) in foods was determined by combining, not modifications, AOAC Official Methods 991.43, 2001.03, and 2002.02. Total NDC included insoluble dietary fiber (IDF) + high-molecular-weight soluble dietary fiber (HMWSDF), nondigestible oligosaccharides (NDO) not precipitated in ethanol solution, and resistant starch (RS). Eight sources of NDC (cellulose, wheat bran, gum arabic, resistant maltodextrin, polydextrose, fructooligosaccharide, galactooligosaccharides, and RS) were incorporated in different combinations into standard formula bread samples. All of the NDC sources and bread samples were analyzed for their (1) IDF + HMWSDF content with corrections for residual RS amount using AOAC Official Method 991.43, (2) NDO by liquid chromatography (LC) in AOAC Official Method 2001.03, and (3) RS by AOAC Official Method 2002.02. The correlation coefficient (R(2)) comparing calculated amounts versus measured amounts of total NDC in 11 bread samples was 0.92. Analysis of commercial food samples was also well matched with the DF + NDO value on their nutritional label. Consequently, we confirmed a single measurement of LC can determine all NDO in foods, and total NDC in foods can be determined by unifying existing AOAC Official Methods.

  7. Rare earths analysis of rock samples by instrumental neutron activation analysis, internal standard method

    International Nuclear Information System (INIS)

    Silachyov, I.

    2016-01-01

    The application of instrumental neutron activation analysis for the determination of long-lived rare earth elements (REE) in rock samples is considered in this work. Two different methods are statistically compared: the well established external standard method carried out using standard reference materials, and the internal standard method (ISM), using Fe, determined through X-ray fluorescence analysis, as an element-comparator. The ISM proved to be the more precise method for a wide range of REE contents and can be recommended for routine practice. (author)

  8. Comparative gas chromatography-mass spectroscopy, Fourier transform infrared spectroscopy, and high-performance liquid chromatography analysis of essential oils extracted using 4 methods from the leaves of Eucalyptus globulus L.

    Directory of Open Access Journals (Sweden)

    Yasmeen Khan

    2016-01-01

    Full Text Available Background: Eucalyptus globulus L. (family, Myrtaceae is one of the world′s most widely planted genera. E. globulus L., commonly referred to as Tasmanian blue gum, is a fast growing, evergreen tree, native to Tasmania and South-East Australia. Apart from its extensive use in pulp industry, it is also produces Oleum Eucalypti (eucalyptus oil that is extracted on commercial scale in many countries such as China, India, South Africa, Portugal, Brazil, and Tasmania, as a raw material in perfumery, cosmetics, food beverage, aromatherapy, and phytotherapy. Materials and Methods: Traditional hydrodistillation (HD, solvent extraction (SE, ultrasonication (US, and supercritical fluid extraction (SFE were conducted for the extraction of essential oil from the leaves of E. globulus. Each oil was evaluated in terms of high-performance liquid chromatography (HPTLC and Fourier transform infrared spectroscopy (FTIR fingerprinting with qualitative and semi-quantitative composition of the isolated essential oil by gas chromatography-mass spectroscopy (GCMS, the extract yield of essential oil was 2.60%, 2.2%, 2.0%, and 3.6% v/w, respectively, for HD, SE, US, and SFE. Results: A total of 53 compounds were identified by GCMS. Comparative analysis indicated that SFE was favorable for extraction of monoterpene hydrocarbon, sesquiterpene hydrocarbon, and oxygenated sesquiterpene hydrocarbon. HD, SE, and US had certain advantages in the extraction of aliphatic saturated hydrocarbons organic acid and esters. Overlay, FTIR spectra of oil samples obtained by four extraction methods were superimposed with each other showing similar components. The maximum separation of compound seen at 254 nm and lesser at 366 nm by HPTLC fingerprinting which again showed superimposed chromatograms. Conclusion: It is concluded that different extraction method may lead to different yields of essential oils where the choice of appropriate method is very important to obtained more desired

  9. Column liquid chromatography applied to concentrating, separating, and determining platinum metals

    International Nuclear Information System (INIS)

    Alimarin, I.P.; Basova, E.M.; Bol'shova, T.A.; Ivanov, V.M.

    1986-01-01

    The present survey deals with high-performance liquid chromatography (HPLC) in relation to the chromatographic behavior of the platinum metals, including separation and determination. The data shows that HPLC is the most promising and effective method of separating metals, including platinum ones. The method provides efficient separation of microgram amoounts of mixtures with a resolving power 3-20 times that of thin-layer chromatography. It is shown that the most promising line of advance in HPLC for inorganic systems lies in the separation and determination of metals as chelates by absorption or ion-pair chromatography. Examples of using HPLC for determining noble metals in particular cases indicate that the metrological characteristics are favorable

  10. A rapid method for the separation and estimation of uranium in geological materials using ion chromatography

    International Nuclear Information System (INIS)

    Prakash, Satya; Bangroo, P.N.

    2013-01-01

    Ion Chromatography is an elegant analytical technique which was primarily developed for the analysis of anionic species and over the years it has been used successfully to analyse various elements in different matrices. In this work the potential of Ion Chromatography has been used for the rapid separation and estimation of uranium in hydrogeochemical and other geological materials

  11. Determination of telmisartan in human blood plasma: Part II: Liquid chromatography-tandem mass spectrometry method development, comparison to immunoassay and pharmacokinetic study

    NARCIS (Netherlands)

    Hempen, C.M.; Gläsle-Schwarz, Liane; Kunz, Ulrich; Karst, U.

    2006-01-01

    A new liquid chromatography/atmospheric pressure chemical ionization-tandem mass spectrometry (LC/APCI-MS/MS) method with on-line sample clean-up for the determination of telmisartan in human blood plasma is presented. This technique is compared to a previously introduced enzyme-linked immunosorbent

  12. Electrochemical Detectors in HPLC and Ion Chromatography.

    Science.gov (United States)

    Horvai, George; Pungor, ErnÕ

    1989-01-01

    Back in 1952, the renowned Polish electrochemist Wiktor Kemula introduced chromato-polarography, 1 i.e., polaro-graphic detection for liquid chromatography. This technique continued to develop slowly until the early 1970s (for a review see Reference 2) when modem high-performance liquid chromatography (HPLC) emerged. This new, highly efficient chromatographc method could only be. used with detectors ensuring low dispersion. It was not easy to modify the dropping mercury electrode cells to satisfy this requirement. However, at the same time, electroanalytical chemists, who already had much experience in using carbon-based electrodes for oxidative detection in flow analysis, put forward the idea of oxidative amperometric detection in liquid chromatography. 3,4 In this technique, solid or quasi-solid (paste) electrodes were used and this made possible the construction of miniaturized cells with just a few microliter volume.

  13. A method for automating calibration and records management for instrumentation and dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    O`Brien, J.M. Jr.; Rushton, R.O.; Burns, R.E. Jr. [Atlan-Tech, Inc., Roswell, GA (United States)

    1993-12-31

    Current industry requirements are becoming more stringent on quality assurance records and documentation for calibration of instruments and dosimetry. A novel method is presented here that will allow a progressive automation scheme to be used in pursuit of that goal. This concept is based on computer-controlled irradiators that can act as stand-alone devices or be interfaced to other components via a computer local area network. In this way, complete systems can be built with modules to create a records management system to meet the needs of small laboratories or large multi-building calibration groups. Different database engines or formats can be used simply by replacing a module. Modules for temperature and pressure monitoring or shipping and receiving can be added, as well as equipment modules for direct IEEE-488 interface to electrometers and other instrumentation.

  14. A method for automating calibration and records management for instrumentation and dosimetry

    International Nuclear Information System (INIS)

    O'Brien, J.M. Jr.; Rushton, R.O.; Burns, R.E. Jr.

    1993-01-01

    Current industry requirements are becoming more stringent on quality assurance records and documentation for calibration of instruments and dosimetry. A novel method is presented here that will allow a progressive automation scheme to be used in pursuit of that goal. This concept is based on computer-controlled irradiators that can act as stand-alone devices or be interfaced to other components via a computer local area network. In this way, complete systems can be built with modules to create a records management system to meet the needs of small laboratories or large multi-building calibration groups. Different database engines or formats can be used simply by replacing a module. Modules for temperature and pressure monitoring or shipping and receiving can be added, as well as equipment modules for direct IEEE-488 interface to electrometers and other instrumentation

  15. Instrument modifications that produced reduced plate heights supercritical fluid chromatography.

    Science.gov (United States)

    Berger, Terry A

    2016-04-29

    The concept of peak fidelity was shown to be helpful in modeling tubing and detector cell dimensions. Connection tubing and flow cell variances were modeled to determine appropriate internal ID's, lengths, and volumes. A low dispersion plumbing configuration, based on these calculations, was assembled to replace the standard plumbing and produced the reported results. The modifications made were straightforward using commercially available parts. The full theoretical efficiency of a 3×100 mm column packed with 1.8 μm totally porous particles was achieved for the first time in supercritical fluid chromatography (SFC). Peak fidelity of >0.95 was maintained to below k=2. A reduced plate height as low as 1.87 was measured. Thus, true "ultra high performance" SFC was achieved, with the results a major improvement from all previous SFC reports. Since there were no efficiency losses, none could be attributed to thermal gradients caused by the expansion of the fluid over large pressure drops, under the conditions used. Similarly, changes in diffusion coefficients caused by significant decreases in density during expansion are apparently balanced by the increase in linear velocity, keeping the ratio between the diffusion coefficient and the linear velocity a constant. Changing modifier concentration to change retention was shown to not be a significant problem. All these issues have been a concern in the past. Diffusion coefficients, and viscosity data needs to be collected at high pressures before the actual limits of SFC can be discovered. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Experimental innovations in surface science a guide to practical laboratory methods and instruments

    CERN Document Server

    Yates, John T

    2015-01-01

    This book is a new edition of a classic text on experimental methods and instruments in surface science. It offers practical insight useful to chemists, physicists, and materials scientists working in experimental surface science. This enlarged second edition contains almost 300 descriptions of experimental methods. The more than 50 active areas with individual scientific and measurement concepts and activities relevant to each area are presented in this book. The key areas covered are: Vacuum System Technology, Mechanical Fabrication Techniques, Measurement Methods, Thermal Control, Delivery of Adsorbates to Surfaces, UHV Windows, Surface Preparation Methods, High Area Solids, Safety. The book is written for researchers and graduate students.

  17. Analytical methods and laboratory facility for the Defense Waste Processing Facility

    International Nuclear Information System (INIS)

    Coleman, C.J.; Dewberry, R.A.; Lethco, A.J.; Denard, C.D.

    1985-01-01

    This paper describes the analytical methods, instruments, and laboratory that will support vitrification of defense waste. The Defense Waste Processing Facility (DWPF) is now being constructed at Savannah River Plant (SRP). Beginning in 1989, SRP high-level defense waste will be immobilized in borosilicate glass for disposal in a federal repository. The DWPF will contain an analytical laboratory for performing process control analyses. Additional analyses will be performed for process history and process diagnostics. The DWPF analytical facility will consist of a large shielded sampling cell, three shielded analytical cells, a laboratory for instrumental analysis and chemical separations, and a counting room. Special instrumentation is being designed for use in the analytical cells, including microwave drying/dissolution apparatus, and remote pipetting devices. The instrumentation laboratory will contain inductively coupled plasma, atomic absorption, Moessbauer spectrometers, a carbon analyzer, and ion chromatography equipment. Counting equipment will include intrinsic germanium detectors, scintillation counters, Phoswich alpha, beta, gamma detectors, and a low-energy photon detector

  18. Development of a liquid chromatography-electrospray chemical ionization tandem mass spectrometry analytical method for analysis of eleven hydroxylated polybrominated diphenyl ethers.

    Science.gov (United States)

    Feo, Maria Luisa; Barón, Enrique; Aga, Diana S; Eljarrat, Ethel; Barceló, Damià

    2013-08-02

    Recently, hydroxylated polybrominated diphenyl ethers (OH-PBDEs) have emerged as environmentally relevant pollutants due to recent reports of their natural production and metabolism. Recent mechanistic studies in human and rats have shown that some OH-PBDEs are more potent than parent compounds (PBDEs) and may contribute substantially to neurodevelopmental disorders by direct neurotoxicity, or indirectly through altered thyroid disruption. However, analytical methodologies for determination of OH-PBDEs are currently limited. In this study a robust liquid chromatography-electrospray tandem triple quadrupole-linear ion trap mass spectrometer (LC-ESI-QqLIT-MS-MS) in negative mode method was developed for the determination of eleven OH-tri- to OH-hexa-PBDEs. Two different columns were tested and compared for chromatographic separation: a C18 BetaBasic and a Purospher STAR RP 18, working at pH 8 and 10, respectively. Mobile phase (acetonitrile:water) was optimized by changing the pH of the aqueous phase and the concentration of the organic modifier (methanol). The MS-MS parameters (declustering potential (DP), collision energy (CE) and cell exit potential (CXP)) were optimized. Selected reaction monitoring (SRM) was used in order to increase sensitivity. Two SRM transitions ([M-H](-)>[Br](-)) were selected for each OH-PBDE, one for quantification and the second one for confirmation. Under the optimized conditions, the instrumental limits of detection were between 0.17 and 0.72injectedpg. The method provided good linearity (r>0.99 for a concentration range of 0.30-100ng/mL), accuracy and precision (%Dev and %RSD≤20% for intra- and inter-assays). Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Optimization of ultra-performance liquid chromatography (UPLC) with fluorescence detector (FLD) method for the quantitative determination of selected neurotransmitters in rat brain.

    Science.gov (United States)

    Stragierowicz, Joanna; Daragó, Adam; Brzeźnicki, Sławomir; Kilanowicz, Anna

    2017-07-26

    Glutamate (Glu) and γ-aminobutyric acid (GABA) are the main neurotransmitters in the central nervous system for excitatory and inhibitory processes, respectively. Monitoring these neurotransmitters is an essential tool in establishing pathological functions, among others in terms of occupational exposure to toxic substances. We present modification of the HPLC (high-performance liquid chromatography) to the UPLC (ultra-performance liquid chromatography) method for the simultaneous determination of glutamate and γ-aminobutyric acid in a single injection. The isocratic separation of these neurotransmitter derivatives was performed on Waters Acquity BEH (ethylene bridged hybrid) C18 column with particle size of 1.7 μm at 35°C using a mobile phase consisting of 0.1 M acetate buffer (pH 6.0) and methanol (60:40, v/v) at a flow rate of 0.3 ml/min. The analytes were detected with the fluorescence detector (FLD) using derivatization with o-phthaldialdehyde (OPA), resulting in excitation at 340 nm and emission at 455 nm. Several validation parameters including linearity (0.999), accuracy (101.1%), intra-day precision (1.52-1.84%), inter-day precision (2.47-3.12%), limit of detection (5-30 ng/ml) and quantification (100 ng/ml) were examined. The developed method was also used for the determination of these neurotransmitters in homogenates of selected rat brain structures. The presented UPLC-FLD is characterized by shorter separation time (3.5 min), which is an adaptation of the similar HPLC methods and is an alternative for more expensive references techniques such as liquid chromatography coupled with tandem mass-spectrometry (LC-MS/MS) methods. Med Pr 2017;68(5):583-591. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  20. Metal-organic frameworks in chromatography.

    Science.gov (United States)

    Yusuf, Kareem; Aqel, Ahmad; ALOthman, Zeid

    2014-06-27

    Metal-organic frameworks (MOFs) emerged approximately two decades ago and are the youngest class of porous materials. Despite their short existence, MOFs are finding applications in a variety of fields because of their outstanding chemical and physical properties. This review article focuses on the applications of MOFs in chromatography, including high-performance liquid chromatography (HPLC), gas chromatography (GC), and other chromatographic techniques. The use of MOFs in chromatography has already had a significant impact; however, the utilisation of MOFs in chromatography is still less common than other applications, and the number of MOF materials explored in chromatography applications is limited. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Analysis of Biological Interactions by Affinity Chromatography: Clinical and Pharmaceutical Applications.

    Science.gov (United States)

    Hage, David S

    2017-06-01

    The interactions between biochemical and chemical agents in the body are important in many clinical processes. Affinity chromatography and high-performance affinity chromatography (HPAC), in which a column contains an immobilized biologically related binding agent, are 2 methods that can be used to study these interactions. This review presents various approaches that can be used in affinity chromatography and HPAC to characterize the strength or rate of a biological interaction, the number and types of sites that are involved in this process, and the interactions between multiple solutes for the same binding agent. A number of applications for these methods are examined, with an emphasis on recent developments and high-performance affinity methods. These applications include the use of these techniques for fundamental studies of biological interactions, high-throughput screening of drugs, work with modified proteins, tools for personalized medicine, and studies of drug-drug competition for a common binding agent. The wide range of formats and detection methods that can be used with affinity chromatography and HPAC for examining biological interactions makes these tools attractive for various clinical and pharmaceutical applications. Future directions in the development of small-scale columns and the coupling of these methods with other techniques, such as mass spectrometry or other separation methods, should continue to increase the flexibility and ease with which these approaches can be used in work involving clinical or pharmaceutical samples. © 2016 American Association for Clinical Chemistry.

  2. Validation of an analytical method for the determination of spiramycin, virginiamycin and tylosin in feeding-stuffs bij thin-layer chromatography and bio-autography

    NARCIS (Netherlands)

    Vincent, U.; Gizzi, G.; Holst, von C.; Jong, de J.; Michard, J.

    2007-01-01

    An inter-laboratory validation was carried out to determine the performance characteristics of an analytical method based on thin-layer chromatography (TLC) coupled to microbiological detection (bio-autography) for screening feed samples for the presence of spiramycin, tylosin and virginiamycin.

  3. Comparison of extraction methods for the analysis of natural dyes in historical textiles by high-performance liquid chromatography.

    Science.gov (United States)

    Valianou, Lemonia; Karapanagiotis, Ioannis; Chryssoulakis, Yannis

    2009-12-01

    Different methods for the extraction of Dactylopius coccus Costa, Rubia tinctorum L., Isatis tinctoria L., Reseda luteola L., Curcuma longa L. and Cotinus coggygria Scop. from wool fibres are investigated using high-performance liquid chromatography with diode array detector (HPLC-DAD). The efficiencies of five extraction methods which include the use of HCl (widely used extraction method), citric acid, oxalic acid, TFA and a combination of HCOOH and EDTA are compared on the basis of the (a) number, (b) relative quantities, measured as HPLC peak areas and (c) signal-to-noise ratios (S/N) of the compounds extracted from the wool substrates. Flavonoid glycosides and curcuminoids contained in R. luteola L. and C. longa L., respectively, according to liquid chromatography with mass spectrometry (LC-MS) identifications, are not detected after treating the fibres with HCl. All the other milder methods are successful in extracting these compounds. Experiments are performed using HPLC-DAD to compare the HPLC peak areas and the S/N of the following extracted compounds: indigotin, indirubin, curcumin, demethoxycurcumin, bisdemethoxycurcumin, fisetin, sulfuretin, luteolin, luteolin-7-O-glucoside, apigenin, carminic acid, alizarin, puruprin and rubiadin. It is shown that the TFA method provides overall the best results as it gives elevated extraction yields except for fisetin, luteolin, apigenin and luteolin-7-O-glucoside and highest S/N except for fisetin and luteolin-7-O-glucoside. It is noteworthy that treatment of the fibres with the typical HCl extraction method results overall in very low S/N. The TFA method is selected for further studies, as follows. First, it is applied on silk dyed samples and compared with the HCl method. The same relative differences of the TFA and HCl methods observed for the wool dyed samples are reported for the silk dyed samples too, except for rubiadin, luteolin and apigenin. Thus, in most cases, the nature of the substrate (wool or silk

  4. High performance liquid chromatography method for the determination of cinnamyl alcohol dehydrogenase activity in soybean roots.

    Science.gov (United States)

    dos Santos, W D; Ferrarese, Maria de Lourdes Lucio; Ferrarese-Filho, O

    2006-01-01

    This study proposes a simple, quick and reliable method for determining the cinnamyl alcohol dehydrogenase (CAD; EC 1.1.1.195) activity in soybean (Glycine max L. Merr.) roots using reversed-phase high performance liquid chromatography (RP-HPLC). The method includes a single extraction of the tissue and conduction of the enzymatic reaction at 30 degrees C with cinnamaldehydes (coniferyl or sinapyl), substrates of CAD. Disappearance of the substrates in the reaction mixture is monitored at 340 nm (for coniferaldehyde) or 345 nm (for sinapaldehyde) by isocratic elution with methanol/acetic acid through a GLC-ODS (M) column. This HPLC technique furnishes a rapid and reliable measure of cinnamaldehyde substrates, and may be used as an alternative tool to analyze CAD activity in enzyme preparation without previous purification.

  5. Development and validation of a thin-layer chromatography method for stability studies of naproxen

    International Nuclear Information System (INIS)

    Rodriguez Hernandez, Yaslenis; Suarez Perez, Yania; Garcia Pulpeiro, Oscar; Rodriguez Borges, Tania

    2011-01-01

    The validation of an analytical method was carried out to be applied to the stability studies of the future formulations of naproxen suppositories for infant and adult use. The factors which mostly influenced in the naproxen stability were determined, the major degradation occurred in oxidizing acid medium and by action of light. The possible formation of esters between the free carboxyl group present in naproxen and the glyceryl monoestereate present in the base was identified as one of the degradation paths in the new formulation. The results were satisfactory. A thin-layer chromatography-based method was developed as well as the best chromatographic conditions were selected. GF 254 silica gel plates and ultraviolet developer at 254 nm were employed. Three solvent systems were evaluated of which A made up of glacial acetic: tetrahydrofurane:toluene (3:9:90 v/v/v)allowed adequate resolution between the analyte and the possible degradation products, with detection limit of 1 μg. The use of the suggested method was restricted to the identification of possible degradation products just for qualitative purposes and not as final test. The method proved to be sensitive and selective enough to be applied for the stated objective, according to the validation results

  6. Study of Separation and Identification of the Active Ingredients in Gardenia jasminoides Ellis Based on a Two-Dimensional Liquid Chromatography by Coupling Reversed Phase Liquid Chromatography and Hydrophilic Interaction Liquid Chromatography.

    Science.gov (United States)

    Zhou, Xuan; Chen, Cen; Ye, Xiaolan; Song, Fenyun; Fan, Guorong; Wu, Fuhai

    2017-01-01

    In this paper, by coupling reversed phase liquid chromatography (RPLC) and hydrophilic interaction liquid chromatography (HILIC), a two-dimensional liquid chromatography system was developed for separation and identification of the active ingredients in Gardenia jasminoides Ellis (GJE). By applying the semi-preparative C18 column as the first dimension and the core-shell column as the second dimension, a total of 896 peaks of GJE were separated. Among the 896 peaks, 16 active ingredients including geniposide, gardenoside, gardoside, etc. were identified by mass spectrometry analysis. The results indicated that the proposed two-dimensional RPLC/HILIC system was an effective method for the analysis of GJE and might hold a high potential to become a useful tool for analysis of other complex mixtures. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Screening anti-tumor compounds from Ligusticum wallichii using cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry.

    Science.gov (United States)

    Zhang, Tao; Ding, Yuanyuan; An, Hongli; Feng, Liuxin; Wang, Sicen

    2015-07-14

    Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry was developed. Tyrosine 367 Cysteine-HEK293 cells were used as cell membrane stationary phase. Specificity and reproducibility of the cell membrane chromatography was evaluated using 1-tert-butyl-3-{2-[4-(diethylamino)butylamino]-6-(3,5-dimethoxyphenyl)pyrido[2,3-d]pyrimidin-7-yl}urea, Nimodipine and dexamethasone acetate. Then, anti-tumor components acting on Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 were screened and identified from extracts of Ligusticum wallichii. Components from the extract were retained on the cell membrane chromatographic column. The retained fraction was directly eluted into high-performance liquid chromatography with mass spectrometry system for separation and identification. Finally, Levistolide A was identified as an active component from Ligusticum wallichii extracts. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide-formazan colorimetric assay revealed that Levistolide A inhibits proliferation of overexpressing the mutated receptor cells with dose-dependent manner. Phosphorylation of fibroblast growth factor receptor 4 was also decrease under Levistolide A treatment. Flex dock simulation verified that Levistolide A could bind with the tyrosine kinase domain of fibroblast growth factor receptor 4. Therefore, Levistolide A screened by the cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry can arrest cell growth. In conclusion, the two-dimensional high-performance liquid chromatography method can screen and identify potential anti-tumor ingredients which specifically act on the tyrosine kinase domain of the mutated fibroblast growth factor receptor 4. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Development of a method based on on-line reversed phase liquid chromatography and gas chromatography coupled by means of an adsorption-desorption interface for the analysis of selected chiral volatile compounds in methyl jasmonate treated strawberries.

    Science.gov (United States)

    de la Peña Moreno, Fernando; Blanch, Gracia Patricia; Flores, Gema; Ruiz Del Castillo, Maria Luisa

    2010-02-12

    A method based on the use of the through oven transfer adsorption-desorption (TOTAD) interface in on-line coupling between reversed phase liquid chromatography and gas chromatography (RPLC-GC) for the determination of chiral volatile compounds was developed. In particular, the method was applied to the study of the influence of methyl jasmonate (MJ) treatment on the production and enantiomeric composition of selected aroma compounds in strawberry. The compounds studied were ethyl 2-methylbutanoate, linalool and 4-hydroxy-2,5-dimethyl-3(2H)-furanone (i.e. furaneol), which were examined on days 3, 6 and 9 after treatment. The method developed resulted in relative standard deviations (RSDs) of 21.6%, 8.1% and 9.8% and limits of detection (LD) of 0.04, 0.07 and 0.02mg/l for ethyl 2-methylbutanoate, linalool and furaneol, respectively. The application of the RPLC-TOTAD-GC method allowed higher levels of ethyl 2-methylbutanoate, linalool and furaneol to be detected, particularly after 9 days of treatment. Besides, MJ demonstrated to affect the enantiomeric distribution of ethyl 2-methylbutanoate. On the contrary, the enantiomeric composition of linalool and furaneol kept constant in both control and MJ-treated strawberries throughout the study. These results are discussed. Copyright 2009 Elsevier B.V. All rights reserved.

  9. Estimation of the quantification uncertainty from flow injection and liquid chromatography transient signals in inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Laborda, Francisco; Medrano, Jesus; Castillo, Juan R.

    2004-01-01

    The quality of the quantitative results obtained from transient signals in high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) and flow injection-inductively coupled plasma mass spectrometry (FI-ICPMS) was investigated under multielement conditions. Quantification methods were based on multiple-point calibration by simple and weighted linear regression, and double-point calibration (measurement of the baseline and one standard). An uncertainty model, which includes the main sources of uncertainty from FI-ICPMS and HPLC-ICPMS (signal measurement, sample flow rate and injection volume), was developed to estimate peak area uncertainties and statistical weights used in weighted linear regression. The behaviour of the ICPMS instrument was characterized in order to be considered in the model, concluding that the instrument works as a concentration detector when it is used to monitorize transient signals from flow injection or chromatographic separations. Proper quantification by the three calibration methods was achieved when compared to reference materials, although the double-point calibration allowed to obtain results of the same quality as the multiple-point calibration, shortening the calibration time. Relative expanded uncertainties ranged from 10-20% for concentrations around the LOQ to 5% for concentrations higher than 100 times the LOQ

  10. Csaba Horváth and preparative liquid chromatography.

    Science.gov (United States)

    Guiochon, Georges

    2005-06-24

    Few chromatographers have been interested in furthering preparative liquid chromatography. The pioneers, Tswett, Kuhn and Lederer, A.J.P. Martin, Tiselius, isolated fractions but as an intermediate step in the analysis of their samples. The progress in electronics and sensors, and in their miniaturization has lead to the paradoxical situation that the analysts never see the transient pure fractions that their detector quantitates. Yet, over the last 25 years, preparative liquid chromatography has become an important industrial process for the separation, the extraction, and/or the purification of many pharmaceuticals or pharmaceutical intermediates, including pure enantiomers, purified peptides and proteins, compounds that are manufactured at the relatively large industrial scale of a few kilograms to several hundred tons per year. This development that has strongly affected the modem pharmaceutical industry is mainly due to the pioneering work of Csaba Horváth. His work in preparative HPLC was critical at both the practical and the theoretical levels. He was the first scientist in modem times to pay serious attention to the relationships between the curvature of the equilibrium isotherms, the competitive nature of nonlinear isotherms, and the chromatographic band profiles of complex mixtures. The thermodynamics of multi-component phase equilibria and mass transfer kinetics in chromatography attracted his interest and were the focus of ground-breaking contributions. He investigated displacement chromatography, an old method invented by Tiselius that Csaba was first to implement in HPLC. This choice was explained by the essential characteristic of displacement chromatography, in that it delivers fractions that can be far more concentrated than the feed. Remarkably, once the basics of nonlinear chromatography had been mastered in his group, most of the applications that were studied by his coworkers dealt with peptides of various sizes and with proteins. Thus, all

  11. Validation of high-performance liquid chromatography (HPLC method for quantitative analysis of histamine in fish and fishery products

    Directory of Open Access Journals (Sweden)

    B.K.K.K. Jinadasa

    2016-12-01

    Full Text Available A high-performance liquid chromatography method is described for quantitative determination and validation of histamine in fish and fishery product samples. Histamine is extracted from fish/fishery products by homogenizing with tri-chloro acetic acid, separated with Amberlite CG-50 resin and C18-ODS Hypersil reversed phase column at ambient temperature (25°C. Linear standard curves with high correlation coefficients were obtained. An isocratic elution program was used; the total elution time was 10 min. The method was validated by assessing the following aspects; specificity, repeatability, reproducibility, linearity, recovery, limits of detection, limit of quantification and uncertainty. The validated parameters are in good agreement with method and it is a useful tool for determining histamine in fish and fishery products.

  12. Gas chromatography at the Tritium Laboratory Karlsruhe

    International Nuclear Information System (INIS)

    Laesser, R.; Gruenhagen, S.

    2003-08-01

    Among the analytical techniques (mass spectrometry, laser Raman spectroscopy, gas chromatography, use of ionisation chambers) employed at the Tritium Laboratory Karlsruhe (TLK), gas chromatography plays a prominent role. The main reasons for that are the simplicity of the gas chromatographic separation process, the small space required for the equipment, the low investment costs in comparison to other methods, the robustness of the equipment, the simple and straightforward analysis and the fact that all gas species of interest (with the exception of water) can easily be detected by gas chromatographic means. The conventional gas chromatographs GC1 and GC2 used in the Tritium Measurement Techniques (TMT) System of the TLK and the gas chromatograph GC3 of the experiment CAPER are presented in detail, by discussing their flow diagrams, their major components, the chromatograms measured by means of various detectors, shortcomings and possible improvements. One of the main disadvantages of the conventional gas chromatography is the long retention times required for the analysis of hydrogen gas mixtures. To overcome this disadvantage, micro gas chromatography for hydrogen analysis was developed. Reduction of the retention times by one order of magnitude was achieved. (orig.)

  13. Implementation of Gas Chromatography and Microscale Distillation into the General Chemistry Laboratory Curriculum as Vehicles for Examining Intermolecular Forces

    Science.gov (United States)

    Csizmar, Clifford M.; Force, Dee Ann; Warner, Don L.

    2011-01-01

    As part of an NSF-funded Course Curriculum and Laboratory Improvement (CCLI) project that seeks, in part, to increase student exposure to scientific instrumentation, a gas chromatography experiment has been integrated into the second-semester general chemistry laboratory curriculum. The experiment uses affordable, commercially available equipment…

  14. Affinity monolith chromatography: A review of general principles and applications.

    Science.gov (United States)

    Li, Zhao; Rodriguez, Elliott; Azaria, Shiden; Pekarek, Allegra; Hage, David S

    2017-11-01

    Affinity monolith chromatography, or AMC, is a liquid chromatographic method in which the support is a monolith and the stationary phase is a biological-binding agent or related mimic. AMC has become popular for the isolation of biochemicals, for the measurement of various analytes, and for studying biological interactions. This review will examine the principles and applications of AMC. The materials that have been used to prepare AMC columns will be discussed, which have included various organic polymers, silica, agarose, and cryogels. Immobilization schemes that have been used in AMC will also be considered. Various binding agents and applications that have been reported for AMC will then be described. These applications will include the use of AMC for bioaffinity chromatography, immunoaffinity chromatography, dye-ligand affinity chromatography, and immobilized metal-ion affinity chromatography. The use of AMC with chiral stationary phases and as a tool to characterize biological interactions will also be examined. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. EPA Method 8321B (SW-846): Solvent-Extractable Nonvolatile Compounds by High Performance Liquid Chromatography-Thermospray-Mass Spectrometry (HPLC-TS-MS) or Ultraviolet (UV) Detection

    Science.gov (United States)

    Method 8321B describes procedures for preparation and analysis of solid, aqueous liquid, drinking water and wipe samples using high performance liquid chromatography and mass spectrometry for extractable non-volatile compounds.

  16. Current practice of liquid chromatography-mass spectrometry in metabolomics and metabonomics.

    Science.gov (United States)

    Gika, Helen G; Theodoridis, Georgios A; Plumb, Robert S; Wilson, Ian D

    2014-01-01

    Based on publication and citation numbers liquid chromatography (LC-MS) has become the major analytical technology in the field of global metabolite profiling. This dominance reflects significant investments from both the research community and instrument manufacturers. Here an overview of the approaches taken for LC-MS-based metabolomics research is given, describing critical steps in the realisation of such studies: study design and its needs, specific technological problems to be addressed and major obstacles in data treatment and biomarker identification. The current state of the art for LC-MS-based analysis in metabonomics/metabolomics is described including recent developments in liquid chromatography, mass spectrometry and data treatment as these are applied in metabolomics underlining the challenges, limitations and prospects for metabolomics research. Examples of the application of metabolite profiling in the life sciences focusing on disease biomarker discovery are highlighted. In addition, new developments and future prospects are described. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Use of micro gas chromatography in the fuel cycle of fusion reactors

    International Nuclear Information System (INIS)

    Laesser, R.; Gruenhagen, S.; Kawamura, Y.

    2003-01-01

    Various analytical techniques exist to determine the compositions of gases handled in the fuel cycle of future fusion machines. Gas chromatography was found to be the most appropriate method. The main disadvantages of conventional gas chromatography were the long retention times for the heavy hydrogen species of >30 min. Recent progress in the development of micro-gas chromatography has reduced these retention times to ∼3 min. The usefulness of micro-gas chromatography for the analysis of hydrogen and impurity gas mixtures in the fuel cycle of future fusion machines is presented and the advantages and drawbacks are discussed

  18. Amphenicols stability in medicated feed – development and validation of liquid chromatography method

    Directory of Open Access Journals (Sweden)

    Pietro Wojciech Jerzy

    2014-12-01

    Full Text Available A liquid chromatography-ultraviolet detection method for the determination of florfenicol (FF and thiamphenicol (TAP in feeds is presented. The method comprises the extraction of analytes from the matrix with a mixture of methanol and acetonitrile, drying of the extract, and its dissolution in phosphate buffer. The analysis was performed with a gradient programme of the mobile phase composed of acetonitrile and buffer (pH = 7.3 on a Zorbax Eclipse Plus C18 (150 × 4.6 mm, 5 μm analytical column with UV (λ = 220 nm detection. The analytical procedure has been successfully adopted and validated for quantitative determination of florfenicol and thiamphenicol in feed samples. Sensitivity, specificity, linearity, repeatability, and intralaboratory reproducibility were included in the validation. The mean recovery of amphenicols was 93.5% within the working range of 50-4000 mg/kg. Simultaneous determination of chloramphenicol, which is banned in the feed, was also included within the same procedure of FF and TAP stability studies. Storing the medicated feed at room temperature for up to one month decreased concentration in the investigated drugs even by 45%. These findings are relevant to successful provision of therapy to animals.

  19. Comparison of different transition metal ions for immobilized metal affinity chromatography of selenoprotein P from human plasma

    DEFF Research Database (Denmark)

    Sidenius, U; Farver, O; Jøns, O

    1999-01-01

    Cu2+, Ni2+, Zn2+, Co2+ and Cd2+ were evaluated in metal ion affinity chromatography for enrichment of selenoprotein P, and immobilized Co2+ affinity chromatography was found to be the most selective chromatographic method. The chromatography was performed by fast protein liquid chromatography...

  20. The potential of soft computing methods in NPP instrumentation and control

    International Nuclear Information System (INIS)

    Hampel, R.; Chaker, N.; Kaestner, W.; Traichel, A.; Wagenknecht, M.; Gocht, U.

    2002-01-01

    The method of signal processing by soft computing include the application of fuzzy logic, synthetic neural networks, and evolutionary algorithms. The article contains an outline of the objectives and results of the application of fuzzy logic and methods of synthetic neural networks in nuclear measurement and control. The special requirements to be met by the software in safety-related areas with respect to reliability, evaluation, and validation are described. Possible uses may be in off-line applications in modeling, simulation, and reliability analysis as well as in on-line applications (real-time systems) for instrumentation and control. Safety-related aspects of signal processing are described and analyzed for the fuzzy logic and synthetic neural network concepts. Application are covered in selected examples. (orig.)

  1. Intercomparison of the measurements of oxalic acid in aerosols by gas chromatography and ion chromatography

    Science.gov (United States)

    Kawamura, Kimitaka; Barrie, Leonard A.; Toom-Sauntry, Desiree

    2010-12-01

    Oxalate, the anion of oxalic acid, is one of the most abundant measurable organic species in atmospheric aerosols. Traditionally, this bifunctional species has been measured by gas chromatography (GC) after derivatization to butyl ester and by ion chromatography (IC) without derivatization. However, there are few published comparisons of the two techniques. Here, we report the results of an intercomparison study for the measurement of oxalic acid in Arctic aerosols (oxalic acid by GC ranged from 6.5-59.1 ng m -3 (av. 26.0 ng m -3, median 26.2 ng m -3) whereas those by IC ranged from 6.6-52.1 ng m -3 (av. 26.6 ng m -3, median 25.4 ng m -3). They showed a good correlation ( r = 0.84) with a slope of 0.96. Thus, observations of oxalate obtained by GC employing dibutyl esters are almost equal to those by IC. Because the accuracy of oxalic acid by GC method largely depends on the method used, it is important to strictly examine the recovery in each study.

  2. Liquid chromatography in migration studies

    International Nuclear Information System (INIS)

    Carlsen, L.; Batsberg, W.

    1982-01-01

    Liquid chromatography ahs been suggested as a facile experimental technique to determine important physico-chemical properties, as permeability, porosity, dispersion-, diffusion-, and sorption charcteristics for geological material as chalk samples. The feasibility of the trechnique as a rapid method to evaluate the possible influence of changes in ground water composition on the migration behavior of radionuclides has been demonstrated

  3. Applying the Mixed Methods Instrument Development and Construct Validation Process: the Transformative Experience Questionnaire

    Science.gov (United States)

    Koskey, Kristin L. K.; Sondergeld, Toni A.; Stewart, Victoria C.; Pugh, Kevin J.

    2018-01-01

    Onwuegbuzie and colleagues proposed the Instrument Development and Construct Validation (IDCV) process as a mixed methods framework for creating and validating measures. Examples applying IDCV are lacking. We provide an illustrative case integrating the Rasch model and cognitive interviews applied to the development of the Transformative…

  4. Instrumental neutron activation analysis - a routine method

    International Nuclear Information System (INIS)

    Bruin, M. de.

    1983-01-01

    This thesis describes the way in which at IRI instrumental neutron activation analysis (INAA) has been developed into an automated system for routine analysis. The basis of this work are 20 publications describing the development of INAA since 1968. (Auth.)

  5. Sensitive method for the quantitative determination of bromocriptine in human plasma by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Salvador, Arnaud; Dubreuil, Didier; Denouel, Jannick; Millerioux, L

    2005-06-25

    A sensitive LC-MS-MS assay for the quantitative determination of bromocriptine has been developed and validated and is described in this work. The assay involved the extraction of the analyte from 1 ml of human plasma using a solid phase extraction on Oasis MCX cartridges. Chromatography was performed on a Symmetry C18 (2.1 mm x 100 mm, 3.5 microm) column using a mobile phase consisting of 25:75:01 acetonitrile-water-formic acid with a flow rate of 250 microl/min. The linearity was within the concentration range of 2-500 pg/ml. The lower limit of quantification was 2 pg/ml. This method has been demonstrated to be an improvement over existing methods due to its greater sensitivity and specificity.

  6. Liquid chromatography-tandem mass spectrometry method for determination of panel of neurotransmitters in cerebrospinal fluid from the rat model for tauopathy.

    Science.gov (United States)

    Kovac, Andrej; Somikova, Zuzana; Zilka, Norbert; Novak, Michal

    2014-02-01

    Alzheimer's disease (AD) is still being recognized today as an unmet medical need. Currently, there is no cure and early preclinical diagnostic assay available for AD. Therefore much attention is now being directed at the development of novel methods for quantitative determination of AD biomarkers in the cerebrospinal fluid (CSF). Here, we describe the liquid chromatography-tandem mass spectrometry method for determination of 5-hydroxytryptamine (SER), 5-hydroxyindoleacetic acid (5-HIAA), homovanilic acid (HVA), noradrenaline (NADR), adrenaline (ADR), dopamine (DA), glutamic acid (Glu), γ-aminobutyric acid (GABA), 3,4-dihydroxyphenylacetic acid (DOPAC) and histamine (HIS) in cerebrospinal fluid (CSF) from the rat model for human tauopathy. The benzoyl chloride was used as pre-column derivatization reagents. Neurotransmitters and metabolites were analysed on ultra performance liquid chromatography (UPLC) on C18 column in combination with tandem mass spectrometry. The method is simple, highly sensitive and showed excellent linearity with regression coefficients higher than 0.99. The accuracy was in a range of 93-113% for all analytes. The inter-day precision (n=5 days), expressed as %RSD, was in a range 2-10% for all analytes. Using this method we detected significant changes of CSF levels of two important neurotransmitters/metabolites, ADR and 5-HIAA, which correlates with progression of neurodegeneration in our animal model. © 2013 Published by Elsevier B.V.

  7. Gas Chromatography and Mass Spectrometry Measurements and Protocols for Database and Library Development Relating to Organic Species in Support of the Mars Science Laboratory

    Science.gov (United States)

    Misra, P.; Garcia, R.; Mahaffy, P. R.

    2010-04-01

    An organic contaminant database and library has been developed for use with the Sample Analysis at Mars (SAM) instrumentation utilizing laboratory-based Gas Chromatography-Mass Spectrometry measurements of pyrolyzed and baked material samples.

  8. [Analysis of microalbuminuria with immunonephelometry and high performance liquid chromatography. Evaluation of new criteria].

    Science.gov (United States)

    Markó, Lajos; Molnár, Gergo Attila; Wagner, Zoltán; Koszegi, Tamás; Matus, Zoltán; Mohás, Márton; Kuzma, Mónika; Szijártó, István András; Wittmann, István

    2008-01-13

    Hypertension as well as type 2 diabetes mellitus is a major factor in population mortality. Both diseases damage the endothelium, the early sign of which is microalbuminuria, which can be screened by dipstick and can be diagnosed by using immuno-based and high performance liquid chromatography methods. Using high performance liquid chromatography, the non-immunoreactive albumin can be detected as well. The authors aimed at the examination of albuminuria in the case of immunonephelometrically negative patients with high performance liquid chromatography, in diabetic and hypertensive and non-diabetic hypertensive populations. The authors also wanted to compare the present (albumin-creatinine ratio: male: > or =2.5 mg/mmol, female: > or =3.5 mg/mmol) and a new criteria of the Heart Outcomes Prevention Evaluation study (patients without diabetes: immunological method, > or =0.7 mg/mmol; high performance liquid chromatography, > or =3.1 mg/mmol; individuals with diabetes: immunological method, > or =1.4 mg/mmol; high performance liquid chromatography, > or =5.2 mg/mmol) of microalbuminuria. Examination of fresh urines of 469 microalbuminuria negative patients by dipstick were performed by immunonephelometry. Patients, who were microalbuminuria negative by immunonephelometry as well, were further analyzed by high performance liquid chromatography using the Accumintrade mark Kit, based on size-exclusion chromatography. Three times higher albuminuria were found with high performance liquid chromatography than with immunonephelometry. The intraindividual coefficient of variation did not differ in the two methods (37 +/- 31% vs. 40 +/- 31%, p = 0.869; immunonephelometry vs. high performance liquid chromatography; mean +/- standard deviation). Using the present criteria for microalbuminuria, 43% of immunonephelometrically negative patients proved to be microalbuminuric by high performance liquid chromatography. Using the new criteria of the Heart Outcomes Prevention

  9. A general screening method for doping agents in human urine by solid phase extraction and liquid chromatography/time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kolmonen, Marjo [Forensic Toxicology Division, Department of Forensic Medicine, University of Helsinki (Finland) and Doping Control Laboratory, United Laboratories Ltd., Helsinki (Finland)]. E-mail: marjo.kolmonen@helsinki.fi; Leinonen, Antti [Doping Control Laboratory, United Laboratories Ltd., Helsinki (Finland); Pelander, Anna [Forensic Toxicology Division, Department of Forensic Medicine, University of Helsinki (Finland); Ojanperae, Ilkka [Forensic Toxicology Division, Department of Forensic Medicine, University of Helsinki (Finland)

    2007-02-28

    A general screening method based on solid phase extraction (SPE) and liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) was developed and investigated with 124 different doping agents, including stimulants, {beta}-blockers, narcotics, {beta}{sub 2}-adrenergic agonists, agents with anti-estrogenic activity, diuretics and cannabinoids. Mixed mode cation exchange/C8 cartridges were applied to SPE, and chromatography was based on gradient elution on a C18 column. Ionization of the analytes was achieved with electrospray ionization in the positive mode. Identification by LC/TOFMS was based on retention time, accurate mass and isotopic pattern. Validation of the method consisted of analysis of specificity, analytical recovery, limit of detection and repeatability. The minimum required performance limit (MRPL), established by World Anti-Doping Agency (WADA), was attained to 97 doping agents. The extraction recoveries varied between 33 and 98% and the median was 58%. Mass accuracy was always better than 5 ppm, corresponding to a maximum mass error of 0.7 mDa. The repeatability of the method for spiked urine samples, expressed as median of relative standard deviations (RSD%) at concentrations of MRPL and 10 times MRPL, were 14% and 9%, respectively. The suitability of the LC/TOFMS method for doping control was demonstrated with authentic urine samples.

  10. Immune chromatography: a quantitative radioimmunological assay

    International Nuclear Information System (INIS)

    Davis, J.W.; Demetriades, M.; Bowen, J.M.

    1984-01-01

    Immune chromatography, a radioimmunological binding assay, employs paper chromatography to separate immune complexes from free antigen and antibodies. During chromatography free antigen and antibodies become distributed throughout the paper, while immune complexes remain near the bottoms of the strips. The chromatographic differences can be made quantitative by using either iodinated antigens or antibodies. Under these conditions nanogram quantities of antigen can be detected or antibodies in sera diluted several 1000-fold. The immune chromatography assay can also be performed as an indirect assay, since the paper strips are cut from nitrocellulose paper. In this case the immune components are absorbed by the paper during chromatography. Antigen is then detected with an iodinated second antibody. The indirect immune chromatography assay is particularly useful for identifying different sera that react with the same antigen. Reaction with the first serum before chromatography reduces the amount of antigen available to the second serum following chromatography. In addition to characterizing the immune chromatography procedure, we discuss the possible applications of chromatography assays for the quantitation of other types of molecular binding interactions. (Auth.)

  11. Comparative Study of Continuous Pralidoxime Infusion versus Intermittent Dosing: Application of High-Performance Liquid Chromatography Method on Serum of Organophosphate Poisoned Patients

    Directory of Open Access Journals (Sweden)

    Girish Thunga

    2013-09-01

    How to cite this article: Thunga G, Pandey S, Nair S, Mylapuri R, Vidyasagar S, Kunhikatta V, et al. Comparative Study of Continuous Pralidoxime Infusion versus Intermittent Dosing: Application of High-Performance Liquid Chromatography Method on Serum of Organophosphate Poisoned Patients. Asia Pac J Med Toxicol 2013;2:105-10.

  12. An on-line normal-phase high performance liquid chromatography method for the rapid detection of radical scavengers in non-polar food matrixes

    NARCIS (Netherlands)

    Zhang, Q.; Klift, van der E.J.C.; Janssen, H.G.; Beek, van T.A.

    2009-01-01

    An on-line method for the rapid pinpointing of radical scavengers in non-polar mixtures like vegetable oils was developed. To avoid problems with dissolving the sample, normal-phase chromatography on bare silica gel was used with mixtures of hexane and methyl tert-butyl ether as the eluent. The high

  13. A cost effective method for the determination of 210Po and 210Pb in environmental materials

    International Nuclear Information System (INIS)

    Clayton, R.F.; Bradley, E.J.

    1995-01-01

    The majority of the methods for the determination of 210 Pb and 210 Po in environmental materials were developed in the 1960s. However, with the advances in technology since that time, particularly in the areas of ion-exchange chromatography and instrumentation, new methods may be more appropriate to measure these radionuclides in environmental media such as foodstuffs. A review was conducted of potentially suitable methods. Four methods were selected for detailed evaluation on the basis of cost and sensitivity. A cheap, sensitive and simple method is recommended for the analysis of 210 Pb and 210 Po in environmental materials

  14. Current role of liquid chromatography coupled to mass spectrometry in clinical toxicology screening methods.

    Science.gov (United States)

    Viette, Véronique; Fathi, Marc; Rudaz, Serge; Hochstrasser, Denis; Veuthey, Jean-Luc

    2011-07-01

    Abstract Toxicological screening is the analysis of a biological specimen to detect and identify compounds in patients admitted to the hospital with acute intoxication of unknown origin. The screening of a wide range of toxicologically relevant compounds in biological samples is a serious challenge for clinical laboratories. The high selectivity and sensitivity of liquid chromatography coupled to mass spectrometry or tandem mass spectrometry technology provides an attractive alternative to the current methods. For these reasons, an increasing number of applications for multi-target screening or general screening of unknown compounds in biological matrices are being published. This paper is an overview of sample clean-up, chromatographic separation and mass spectrometry detection procedures which can be combined to obtain screening methods adapted to the constraints and needs of various laboratories, and none specifically in clinical toxicology. Currently the techniques are in the hands of specialists, principally in academic institutes. However, the evolution in technology should allow application of the techniques as a tool in toxicology laboratories and thus more widespread exploitation of their potential.

  15. Instruments for Water Quality Monitoring

    Science.gov (United States)

    Ballinger, Dwight G.

    1972-01-01

    Presents information regarding available instruments for industries and agencies who must monitor numerous aquatic parameters. Charts denote examples of parameters sampled, testing methods, range and accuracy of test methods, cost analysis, and reliability of instruments. (BL)

  16. Application of coupled affinity-sizing chromatography for the detection of proteolyzed HSA-tagged proteins.

    Science.gov (United States)

    London, Anne Serdakowski; Patel, Kunal; Quinn, Lisa; Lemmerer, Martin

    2015-04-01

    Coupled affinity liquid chromatography and size exclusion chromatography (ALC-SEC) is a technique that has been shown to successfully report product quality of proteins during cell expression and prior to the commencement of downstream processing chromatography steps. This method was applied to monitoring the degradation and subsequent partial remediation of a HSA-tagged protein which showed proteolysis, allowing for rapid cell line development to address this product quality dilemma. This paper outlines the novel application of this method for measuring and addressing protease-induced proteolysis. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Determination of Four Major Saponins in Skin and Endosperm of Seeds of Horse Chestnut (Aesculus Hippocastanum L.) Using High Performance Liquid Chromatography with Positive Confirmation by Thin Layer Chromatography

    OpenAIRE

    Abudayeh, Zead Helmi Mahmoud; Al Azzam, Khaldun Mohammad; Naddaf, Ahmad; Karpiuk, Uliana Vladimirovna; Kislichenko, Viktoria Sergeevna

    2015-01-01

    urpose: To separate and quantify four major saponins in the extracts of the skin and the endosperm of seeds of horse chestnut (Aesculus hippocastanum L.) using ultrasonic solvent extraction followed by a high performance liquid chromatography-diode array detector (HPLC-DAD) with positive confirmation by thin layer chromatography (TLC). Methods: The saponins: escin Ia, escin Ib, isoescin Ia and isoescin Ib were extracted using ultrasonic extraction method. The optimized ex...

  18. Application of liquid column chromatography to preconcentration, separation and determination of platinum metals

    International Nuclear Information System (INIS)

    Alimarin, I.P.; Basova, E.M.; Bol'shova, T.A.; Ivanov, V.M.

    1986-01-01

    Separation and determination of platimum metals using the methods of adsorption, ion-pair, ion-exchange, distributing and sieve chromatography are discussed in the review of literature in 1971-1984. Separation and determination of metals as chelates using the method of adsorption and ion-pair chromatograpy are noted to be most perspective directions of developing highly effective liquid chromatography of inorganic systems

  19. Method for 236U Determination in Seawater Using Flow Injection Extraction Chromatography and Accelerator Mass Spectrometry

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Steier, Peter

    2015-01-01

    An automated analytical method implemented in a flow injection (FI) system was developed for rapid determination of 236U in 10 L seawater samples. 238U was used as a chemical yield tracer for the whole procedure, in which extraction chromatography (UTEVA) was exploited to purify uranium, after...... experimental parameters affecting the analytical effectiveness were investigated and optimized in order to achieve high chemical yields and simple and rapid analysis as well as low procedure background. Besides, the operational conditions for the target preparation prior to the AMS measurement were optimized......, on the basis of studying the coprecipitation behavior of uranium with iron hydroxide. The analytical results indicate that the developed method is simple and robust, providing satisfactory chemical yields (80−100%) and high analysis speed (4 h/sample), which could be an appealing alternative to conventional...

  20. Haemoglobin variants may cause significant differences in haemoglobin A1c as measured by high-performance liquid chromatography and enzymatic methods in diabetic patients: a cross-sectional study.

    Science.gov (United States)

    Otabe, Shuichi; Nakayama, Hitomi; Ohki, Tsuyoshi; Soejima, Eri; Tajiri, Yuji; Yamada, Kentaro

    2017-07-01

    Background We aimed to determine whether the discrepancy between haemoglobin A1c values determined by high-performance liquid chromatography and enzymatic haemoglobin A1c measurements in diabetic patients was clinically relevant. Methods We randomly recruited 1421 outpatients undergoing diabetic treatment and follow-up who underwent at least three haemoglobin A1c measurements between April 2014 and March 2015 at our clinic. In 6369 samples, haemoglobin A1c was simultaneously measured by HA-8160 and MetaboLead (enzymatic assay), and the values were compared. Results haemoglobin A1c measurements by high-performance liquid chromatography and enzymatic assay were strongly correlated (correlation coefficient: 0.9828, linear approximation curve y = 0.9986x - 0.2507). Mean haemoglobin A1c (6.8 ± 1.0%) measured by high-performance liquid chromatography was significantly higher than that measured by enzymatic assay (6.5 ± 1.0%, P liquid chromatography than those from enzymatic assay. Of these, three had Hb Toranomon [β112 (G14) Cys→Trp]. The fourth had Hb Ube-2 [α68 (E17) Asn→Asp]. One other subject presented consistently higher haemoglobin A1c values (>1%) by high-performance liquid chromatography than those from enzymatic assay and was diagnosed with a -77 (T > C) mutation in the δ-globin gene. These unrelated asymptomatic subjects had normal erythrocyte profiles, without anaemia. Conclusions We showed that haemoglobin A1c values measured by high-performance liquid chromatography were significantly higher than those measured by enzymatic assay in diabetic subjects. However, when an oversized deviation (>0.7%) between glycaemic control status and haemoglobin A1c is apparent, clinicians should check the methods used to measure haemoglobin A1c and consider the possible presence of a haemoglobin variant.

  1. Determination of aromatic amines in aqueous extracts of polyurethane foam using hydrophilic interaction liquid chromatography and mass spectrometry

    International Nuclear Information System (INIS)

    Riddar Johnson, Jakob; Karlsson, Daniel; Dalene, Marianne; Skarping, Gunnar

    2010-01-01

    A method is presented for the determination of aromatic amines in aqueous extracts of polyurethane (PUR) foam. The method is based on the extraction of PUR foam using aqueous acetic acid (0.1%, w/v) followed by determination of extracted aromatic amines using hydrophilic interaction liquid chromatography (HILIC) and tandem mass spectrometry (MS/MS) with positive electrospray ionisation. The injections of volumes up to 5 μL of aqueous solutions were made possible by on-column focusing with partially filled loop injections. The fragmentation patterns for 2,4- and 2,6-toluene diamine (TDA) and 4,4'-methylene dianiline (MDA) were clarified by performing a hydrogen-deuterium exchange study. TDA and MDA were determined using trideuterated 2,4- and 2,6-TDA and dideuterated 4,4'-MDA as internal standards. Linear calibration graphs were obtained over the range 0.025-0.5 μg mL -1 with correlation coefficients >0.996 and the instrumental detection limit for each compound was <50 fmol. The stability of the amines was influenced by the matrix, so their concentrations decreased over time. Agreement was observed between the results of analyses of PUR foam extracts by HILIC-MS/MS and results obtained by ethyl chloroformate derivatisation and reversed phase (RP) liquid chromatography-mass spectrometry (LC-MS/MS). TDA was observed to be unstable in extracts of foam but not in pure solutions.

  2. Quality evaluation of moluodan concentrated pill using high-performance liquid chromatography fingerprinting coupled with chemometrics.

    Science.gov (United States)

    Tao, Lingyan; Zhang, Qing; Wu, Yongjiang; Liu, Xuesong

    2016-12-01

    In this study, a fast and effective high-performance liquid chromatography method was developed to obtain a fingerprint chromatogram and quantitative analysis simultaneously of four indexes including gallic acid, chlorogenic acid, albiflorin and paeoniflorin of the traditional Chinese medicine Moluodan Concentrated Pill. The method was performed by using a Waters X-bridge C 18 reversed phase column on an Agilent 1200S high-performance liquid chromatography system coupled with diode array detection. The mobile phase of the high-performance liquid chromatography method was composed of 20 mmol/L phosphate solution and acetonitrile with a 1 mL/min eluent velocity, under a detection temperature of 30°C and a UV detection wavelength of 254 nm. After the methodology validation, 16 batches of Moluodan Concentrated Pill were analyzed by this high-performance liquid chromatography method and both qualitative and quantitative evaluation results were achieved by similarity analysis, principal component analysis and hierarchical cluster analysis. The results of these three chemometrics were in good agreement and all indicated that batch 10 and batch 16 showed significant differences with the other 14 batches. This suggested that the developed high-performance liquid chromatography method could be applied in the quality evaluation of Moluodan Concentrated Pill. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Detailed characterizations of a Comparative Reactivity Method (CRM) instrument: experiments vs. modelling

    Science.gov (United States)

    Michoud, V.; Hansen, R. F.; Locoge, N.; Stevens, P. S.; Dusanter, S.

    2015-04-01

    The Hydroxyl radical (OH) is an important oxidant in the daytime troposphere that controls the lifetime of most trace gases, whose oxidation leads to the formation of harmful secondary pollutants such as ozone (O3) and Secondary Organic Aerosols (SOA). In spite of the importance of OH, uncertainties remain concerning its atmospheric budget and integrated measurements of the total sink of OH can help reducing these uncertainties. In this context, several methods have been developed to measure the first-order loss rate of ambient OH, called total OH reactivity. Among these techniques, the Comparative Reactivity Method (CRM) is promising and has already been widely used in the field and in atmospheric simulation chambers. This technique relies on monitoring competitive OH reactions between a reference molecule (pyrrole) and compounds present in ambient air inside a sampling reactor. However, artefacts and interferences exist for this method and a thorough characterization of the CRM technique is needed. In this study, we present a detailed characterization of a CRM instrument, assessing the corrections that need to be applied on ambient measurements. The main corrections are, in the order of their integration in the data processing: (1) a correction for a change in relative humidity between zero air and ambient air, (2) a correction for the formation of spurious OH when artificially produced HO2 react with NO in the sampling reactor, and (3) a correction for a deviation from pseudo first-order kinetics. The dependences of these artefacts to various measurable parameters, such as the pyrrole-to-OH ratio or the bimolecular reaction rate constants of ambient trace gases with OH are also studied. From these dependences, parameterizations are proposed to correct the OH reactivity measurements from the abovementioned artefacts. A comparison of experimental and simulation results is then discussed. The simulations were performed using a 0-D box model including either (1) a

  4. A candidate liquid chromatography mass spectrometry reference method for the quantification of the cardiac marker 1-32 B-type natriuretic peptide.

    Science.gov (United States)

    Torma, Attila F; Groves, Kate; Biesenbruch, Sabine; Mussell, Chris; Reid, Alan; Ellison, Steve; Cramer, Rainer; Quaglia, Milena

    2017-08-28

    B-type natriuretic peptide (BNP) is a 32 amino acid cardiac hormone routinely measured by immunoassays to diagnose heart failure. While it is reported that immunoassay results can vary up to 45%, no attempt of standardization and/or harmonization through the development of certified reference materials (CRMs) or reference measurement procedures (RMPs) has yet been carried out. B-type natriuretic peptide primary calibrator was quantified traceably to the International System of Units (SI) by both amino acid analysis and tryptic digestion. A method for the stabilization of BNP in plasma followed by protein precipitation, solid phase extraction (SPE) and liquid chromatography (LC) mass spectrometry (MS) was then developed and validated for the quantification of BNP at clinically relevant concentrations (15-150 fmol/g). The candidate reference method was applied to the quantification of BNP in a number of samples from the UK NEQAS Cardiac Markers Scheme to demonstrate its applicability to generate reference values and to preliminary evaluate the commutability of a potential CRM. The results from the reference method were consistently lower than the immunoassay results and discrepancy between the immunoassays was observed confirming previous data. The application of the liquid chromatography-mass spectrometry (LC-MS) method to the UK NEQAS samples and the correlation of the results with the immunoassay results shows the potential of the method to support external quality assessment schemes, to improve understanding of the bias of the assays and to establish RMPs for BNP measurements. Furthermore, the method has the potential to be multiplexed for monitoring circulating truncated forms of BNP.

  5. Simultaneous separation of antihyperlipidemic drugs by green ultrahigh-performance liquid chromatography-diode array detector method: Improving the health of liquid chromatography.

    Science.gov (United States)

    Alghazi, Mansoor; Alanazi, Fars; Mohsin, Kazi; Siddiqui, Nasir Ali; Shakeel, Faiyaz; Haq, Nazrul

    2017-04-01

    Statins in combination with fibrates show beneficial effects on the lipoprotein profile of patients because they have positive complimentary effects on lipid profile. A new green ultrahigh-performance liquid chromatography-diode array detector method for simultaneous analysis of simvastatin (SMV) and fenofibrate (FNF) in standard form, marketed formulations, and self-emulsifying drug delivery system formulations was developed and validated in the present investigation. The method utilized C 18 as stationary phase and a combination of methanol:water (8:2) as an eluent. It was found that selected eluent provided short run time (2.5 minutes), better peak symmetry and satisfactory values of other chromatographic parameters such as resolution (Rs=2.325), capacity factor (k, 3.0 and 4.2 for SMV and FNF, respectively), selectivity (α =1.4), and number of theoretical plates (N, 4265 and 5285 for SMV and FNF, respectively). An excellent linear relationship (r 2 0.998 and 0.997 for SMV and FNF, respectively) was observed for linear regression data for the calibration plots. The developed system was validated for accuracy, precision, robustness (˃ 2% for both drugs) and recovery (98-102% for both drugs). Results obtained from the statistical treatment of the values obtained for different parameters proved that the method is suitable, reproducible, and selective for the simultaneous analysis of SMV and FNF in bulk, marketed, and self-emulsifying drug delivery system formulations. The replacement of commonly applied toxic solvents with innocuous and environmentally benign solvents provides a better option than the more toxic processes in drug analysis. Copyright © 2016. Published by Elsevier B.V.

  6. Optimization of biological and instrumental detection of explosives and ignitable liquid residues including canines, SPME/ITMS and GC/MSn

    Science.gov (United States)

    Furton, Kenneth G.; Harper, Ross J.; Perr, Jeannette M.; Almirall, Jose R.

    2003-09-01

    A comprehensive study and comparison is underway using biological detectors and instrumental methods for the rapid detection of ignitable liquid residues (ILR) and high explosives. Headspace solid phase microextraction (SPME) has been demonstrated to be an effective sampling method helping to identify active odor signature chemicals used by detector dogs to locate forensic specimens as well as a rapid pre-concentration technique prior to instrumental detection. Common ignitable liquids and common military and industrial explosives have been studied including trinitrotoluene, tetryl, RDX, HMX, EGDN, PETN and nitroglycerine. This study focuses on identifying volatile odor signature chemicals present, which can be used to enhance the level and reliability of detection of ILR and explosives by canines and instrumental methods. While most instrumental methods currently in use focus on particles and on parent organic compounds, which are often involatile, characteristic volatile organics are generally also present and can be exploited to enhance detection particularly for well-concealed devices. Specific examples include the volatile odor chemicals 2-ethyl-1-hexanol and cyclohexanone, which are readily available in the headspace of the high explosive composition C-4; whereas, the active chemical cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX) is not. The analysis and identification of these headspace 'fingerprint' organics is followed by double-blind dog trials of the individual components using certified teams in an attempt to isolate and understand the target compounds to which dogs are sensitive. Studies to compare commonly used training aids with the actual target explosive have also been undertaken to determine their suitability and effectiveness. The optimization of solid phase microextraction (SPME) combined with ion trap mobility spectrometry (ITMS) and gas chromatography/mass spectrometry/mass spectrometry (GC/MSn) is detailed including interface development

  7. Nanomaterials as stationary phases and supports in liquid chromatography.

    Science.gov (United States)

    Beeram, Sandya R; Rodriguez, Elliott; Doddavenkatanna, Suresh; Li, Zhao; Pekarek, Allegra; Peev, Darin; Goerl, Kathryn; Trovato, Gianfranco; Hofmann, Tino; Hage, David S

    2017-10-01

    The development of various nanomaterials over the last few decades has led to many applications for these materials in liquid chromatography (LC). This review will look at the types of nanomaterials that have been incorporated into LC systems and the applications that have been explored for such systems. A number of carbon-based nanomaterials and inorganic nanomaterials have been considered for use in LC, ranging from carbon nanotubes, fullerenes and nanodiamonds to metal nanoparticles and nanostructures based on silica, alumina, zirconia and titanium dioxide. Many ways have been described for incorporating these nanomaterials into LC systems. These methods have included covalent immobilization, adsorption, entrapment, and the synthesis or direct development of nanomaterials as part of a chromatographic support. Nanomaterials have been used in many types of LC. These applications have included the reversed-phase, normal-phase, ion-exchange, and affinity modes of LC, as well as related methods such as chiral separations, ion-pair chromatography and hydrophilic interaction liquid chromatography. Both small and large analytes (e.g., dyes, drugs, amino acids, peptides and proteins) have been used to evaluate possible applications for these nanomaterial-based methods. The use of nanomaterials in columns, capillaries and planar chromatography has been considered as part of these efforts. Potential advantages of nanomaterials in these applications have included their good chemical and physical stabilities, the variety of interactions many nanomaterials can have with analytes, and their unique retention properties in some separation formats. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  9. Microbial metabolomics with gas chromatography/mass spectrometry

    NARCIS (Netherlands)

    Koek, M.M.; Muilwijk, B.; Werf, M.J. van der; Hankemeier, T.

    2006-01-01

    An analytical method was set up suitable for the analysis of microbial metabolomes, consisting of an oximation and silylation derivatization reaction and subsequent analysis by gas chromatography coupled to mass spectrometry. Microbial matrixes contain many compounds that potentially interfere with

  10. Development of Validated High-performance Thin-layer Chromatography Method for Simultaneous Determination of Quercetin and Kaempferol in Thespesia populnea.

    Science.gov (United States)

    Panchal, Hiteksha; Amin, Aeshna; Shah, Mamta

    2017-01-01

    Thespesia populnea L. (Family: Malvaceae) is a well-known medicinal plant distributed in tropical regions of the world and cultivated in South Gujarat and indicated to be useful in cutaneous affections, psoriasis, ringworm, and eczema. Bark and fruits are indicated in the diseases of skin, urethritis, and gonorrhea. The juice of fruits is employed in treating certain hepatic diseases. The plant is reported to contain flavonoids, quercetin, kaempferol, gossypetin, Kaempferol-3-monoglucoside, β-sitosterol, kaempferol-7-glucoside, and gossypol. T. populnea is a common component of many herbal and Ayurvedic formulation such as Kamilari and Liv-52. The present study aimed at developing validated and reliable high-performance thin layer chromatography (HPTLC) method for the analysis of quercetin and kaempferol simultaneously in T. populnea . The method employed thin-layer chromatography aluminum sheets precoated with silica gel as the stationary phase and toluene: ethyl acetate: formic acid (6:4:0.3 v/v/v) as the mobile phase, which gave compact bands of quercetin and kaempferol. Linear regression data for the calibration curves of standard quercetin and kaempferol showed a good linear relationship over a concentration range of 100-600 ng/spot and 500-3000 ng/spot with respect to the area and correlation coefficient (R2) was 0.9955 and 0.9967. The method was evaluated regarding accuracy, precision, selectivity, and robustness. Limits of detection and quantitation were recorded as 32.06 and 85.33 ng/spot and 74.055 and 243.72 ng/spot for quercetin and kaempferol, respectively. We concluded that this method employing HPTLC in the quantitative determination of quercetin and kaempferol is efficient, simple, accurate, and validated.

  11. Method Development for Pesticide Residue Analysis in Farmland Soil using High Perfomance Liquid Chromatography

    Science.gov (United States)

    Theresia Djue Tea, Marselina; Sabarudin, Akhmad; Sulistyarti, Hermin

    2018-01-01

    A method for the determination of diazinon and chlorantraniliprole in soil samples has been developed. The analyte was extracted with acetonitrile from farmland soil sample. Determination and quantification of diazinon and chlorantraniliprole were perfomed by high perfomance liquid chromatography (HPLC) with an UV detector. Several parameters of HPLC method were optimized with respect to sensitivity, high resolution of separation, and accurate determination of diazinon and chlorantraniliprole. Optimum conditions for the separation of two pesticides were eluent composition of acetonitrile:water ratio of 60:40, 0.4 mL/min of flow rate, and 220 nm of wavelength. Under the optimum conditions, diazinon linearity was in the range from 1-25 ppm with R2 of 0.9976, 1.19 mgL-1 LOD, and 3.98 mgL-1 LOQ; while the linearity of chlorantraniliprole was in the range from 0.2-5 mgL-1 with R2 of 0.9972, 0.39 mgL-1 LOD, and 1.29 mgL-1 LOQ. When the method was applied to the soil sample, both pesticides showed acceptable recoveries for real sample of more than 85%: thus, the developed method meets the validation requirement. Under this developed method, the concentrations of both pesticides in the soil samples were below the LOD and LOQ (0.577 mgL-1 for diazinon and 0.007 mgL-1 for chlorantraniliprole). Therefore, it can be concluded that the soil samples used in this study have neither diazinon nor chlorantraniliprole.

  12. A method of estimating GPS instrumental biases with a convolution algorithm

    Science.gov (United States)

    Li, Qi; Ma, Guanyi; Lu, Weijun; Wan, Qingtao; Fan, Jiangtao; Wang, Xiaolan; Li, Jinghua; Li, Changhua

    2018-03-01

    This paper presents a method of deriving the instrumental differential code biases (DCBs) of GPS satellites and dual frequency receivers. Considering that the total electron content (TEC) varies smoothly over a small area, one ionospheric pierce point (IPP) and four more nearby IPPs were selected to build an equation with a convolution algorithm. In addition, unknown DCB parameters were arranged into a set of equations with GPS observations in a day unit by assuming that DCBs do not vary within a day. Then, the DCBs of satellites and receivers were determined by solving the equation set with the least-squares fitting technique. The performance of this method is examined by applying it to 361 days in 2014 using the observation data from 1311 GPS Earth Observation Network (GEONET) receivers. The result was crosswise-compared with the DCB estimated by the mesh method and the IONEX products from the Center for Orbit Determination in Europe (CODE). The DCB values derived by this method agree with those of the mesh method and the CODE products, with biases of 0.091 ns and 0.321 ns, respectively. The convolution method's accuracy and stability were quite good and showed improvements over the mesh method.

  13. Role of ion chromatography in the chemical characterization of PFBR MOX fuel

    International Nuclear Information System (INIS)

    Kelkar, Anoop; Das, D.K.; Prakash, Amrit; Behere, P.G.; Afzal, Mohd

    2012-01-01

    Ion chromatography (IC) is multi-element technique with the feasibility of determination of metallic as well as non metallic impurities on a single instrument. IC has been used for various analytical purposes in nuclear industry. lt has advantages of low capital investment, small sample size, less radioactive waste generation, comparable precision to spectroscopic techniques and ease of fume hood/glove box adaptation. Present paper describes the determination of trace metallic (alkali, alkaline earth, transition and lanthanide metal ions) and non metallic impurities in PFBR MOX fuel

  14. Modern Instrumental Methods in Forensic Toxicology*

    Science.gov (United States)

    Smith, Michael L.; Vorce, Shawn P.; Holler, Justin M.; Shimomura, Eric; Magluilo, Joe; Jacobs, Aaron J.; Huestis, Marilyn A.

    2009-01-01

    This article reviews modern analytical instrumentation in forensic toxicology for identification and quantification of drugs and toxins in biological fluids and tissues. A brief description of the theory and inherent strengths and limitations of each methodology is included. The focus is on new technologies that address current analytical limitations. A goal of this review is to encourage innovations to improve our technological capabilities and to encourage use of these analytical techniques in forensic toxicology practice. PMID:17579968

  15. Application of genetic algorithms for parameter estimation in liquid chromatography

    International Nuclear Information System (INIS)

    Hernandez Torres, Reynier; Irizar Mesa, Mirtha; Tavares Camara, Leoncio Diogenes

    2012-01-01

    In chromatography, complex inverse problems related to the parameters estimation and process optimization are presented. Metaheuristics methods are known as general purpose approximated algorithms which seek and hopefully find good solutions at a reasonable computational cost. These methods are iterative process to perform a robust search of a solution space. Genetic algorithms are optimization techniques based on the principles of genetics and natural selection. They have demonstrated very good performance as global optimizers in many types of applications, including inverse problems. In this work, the effectiveness of genetic algorithms is investigated to estimate parameters in liquid chromatography

  16. Spiral Countercurrent Chromatography

    Science.gov (United States)

    Ito, Yoichiro; Knight, Martha; Finn, Thomas M.

    2013-01-01

    For many years, high-speed countercurrent chromatography conducted in open tubing coils has been widely used for the separation of natural and synthetic compounds. In this method, the retention of the stationary phase is solely provided by the Archimedean screw effect by rotating the coiled column in the centrifugal force field. However, the system fails to retain enough of the stationary phase for polar solvent systems such as the aqueous–aqueous polymer phase systems. To address this problem, the geometry of the coiled channel was modified to a spiral configuration so that the system could utilize the radially acting centrifugal force. This successfully improved the retention of the stationary phase. Two different types of spiral columns were fabricated: the spiral disk assembly, made by stacking multiple plastic disks with single or four interwoven spiral channels connected in series, and the spiral tube assembly, made by inserting the tetrafluoroethylene tubing into a spiral frame (spiral tube support). The capabilities of these column assemblies were successfully demonstrated by separations of peptides and proteins with polar two-phase solvent systems whose stationary phases had not been well retained in the earlier multilayer coil separation column for high-speed countercurrent chromatography. PMID:23833207

  17. A damage detection method for instrumented civil structures using prerecorded Green’s functions and cross-correlation

    OpenAIRE

    Heckman, Vanessa; Kohler, Monica; Heaton, Thomas

    2011-01-01

    Automated damage detection methods have application to instrumented structures that are susceptible to types of damage that are difficult or costly to detect. The presented method has application to the detection of brittle fracture of welded beam-column connections in steel moment-resisting frames (MRFs), where locations of potential structural damage are known a priori. The method makes use of a prerecorded catalog of Green’s function templates and a cross-correlation method ...

  18. Column properties and flow profiles of a flat, wide column for high-pressure liquid chromatography.

    Science.gov (United States)

    Mriziq, Khaled S; Guiochon, Georges

    2008-04-11

    The design and the construction of a pressurized, flat, wide column for high-performance liquid chromatography (HPLC) are described. This apparatus, which is derived from instruments that implement over-pressured thin layer chromatography, can carry out only uni-dimensional chromatographic separations. However, it is intended to be the first step in the development of more powerful instruments that will be able to carry out two-dimensional chromatographic separations, in which case, the first separation would be a space-based separation, LC(x), taking place along one side of the bed and the second separation would be a time-based separation, LC(t), as in classical HPLC but proceeding along the flat column, not along a tube. The apparatus described consists of a pressurization chamber made of a Plexiglas block and a column chamber made of stainless steel. These two chambers are separated by a thin Mylar membrane. The column chamber is a cavity which is filled with a thick layer (ca. 1mm) of the stationary phase. Suitable solvent inlet and outlet ports are located on two opposite sides of the sorbent layer. The design allows the preparation of a homogenous sorbent layer suitable to be used as a chromatographic column, the achievement of effective seals of the stationary phase layer against the chamber edges, and the homogenous flow of the mobile phase along the chamber. The entire width of the sorbent layer area can be used to develop separations or elute samples. The reproducible performance of the apparatus is demonstrated by the chromatographic separations of different dyes. This instrument is essentially designed for testing detector arrays to be used in a two-dimensional LC(x) x LC(t) instrument. The further development of two-dimension separation chromatographs based on the apparatus described is sketched.

  19. A sediment extraction and cleanup method for wide-scope multitarget screening by liquid chromatography-high-resolution mass spectrometry.

    Science.gov (United States)

    Massei, Riccardo; Byers, Harry; Beckers, Liza-Marie; Prothmann, Jens; Brack, Werner; Schulze, Tobias; Krauss, Martin

    2018-01-01

    Previous studies on organic sediment contaminants focused mainly on a limited number of highly hydrophobic micropollutants accessible to gas chromatography using nonpolar, aprotic extraction solvents. The development of liquid chromatography-high-resolution mass spectrometry (LC-HRMS) permits the spectrum of analysis to be expanded to a wider range of more polar and ionic compounds present in sediments and allows target, suspect, and nontarget screening to be conducted with high sensitivity and selectivity. In this study, we propose a comprehensive multitarget extraction and sample preparation method for characterization of sediment pollution covering a broad range of physicochemical properties that is suitable for LC-HRMS screening analysis. We optimized pressurized liquid extraction, cleanup, and sample dilution for a target list of 310 compounds. Finally, the method was tested on sediment samples from a small river and its tributaries. The results show that the combination of 100 °C for ethyl acetate-acetone (50:50, neutral extract) followed by 80 °C for acetone-formic acid (100:1, acidic extract) and methanol-10 mM sodium tetraborate in water (90:10, basic extract) offered the best extraction recoveries for 287 of 310 compounds. At a spiking level of 1 μg mL -1 , we obtained satisfactory cleanup recoveries for the neutral extract-(93 ± 23)%-and for the combined acidic/basic extracts-(42 ± 16)%-after solvent exchange. Among the 69 compounds detected in environmental samples, we successfully quantified several pharmaceuticals and polar pesticides.

  20. Comparison of the BioRad Variant and Primus Ultra2 high-pressure liquid chromatography (HPLC) instruments for the detection of variant hemoglobins.

    Science.gov (United States)

    Gosselin, R C; Carlin, A C; Dwyre, D M

    2011-04-01

    Hemoglobin variants are a result of genetic changes resulting in abnormal or dys-synchronous hemoglobin chain production (thalassemia) or the generation of hemoglobin chain variants such as hemoglobin S. Automated high-pressure liquid chromatography (HPLC) systems have become the method of choice for the evaluation of patients suspected with hemoglobinopathies. In this study, we evaluated the performance of two HPLC methods used in the detection of common hemoglobin variants: Variant and Ultra2. There were 377 samples tested, 26% (99/377) with HbS, 8.5% (32/377) with HbC, 20.7% (78/377) with other hemoglobin variant or thalassemia, and 2.9% with increased hemoglobin A(1) c. The interpretations of each chromatograph were compared. There were no differences noted for hemoglobins A(0), S, or C. There were significant differences between HPLC methods for hemoglobins F, A(2), and A(1) c. However, there was good concordance between normal and abnormal interpretations (97.9% and 96.2%, respectively). Both Variant and Ultra2 HPLC methods were able to detect most common hemoglobin variants. There was better discrimination for fast hemoglobins, between hemoglobins E and A(2), and between hemoglobins S and F using the Ultra2 HPLC method. © 2010 Blackwell Publishing Ltd.

  1. Analytical FcRn affinity chromatography for functional characterization of monoclonal antibodies

    Science.gov (United States)

    Schlothauer, Tilman; Rueger, Petra; Stracke, Jan Olaf; Hertenberger, Hubert; Fingas, Felix; Kling, Lothar; Emrich, Thomas; Drabner, Georg; Seeber, Stefan; Auer, Johannes; Koch, Stefan; Papadimitriou, Apollon

    2013-01-01

    The neonatal Fc receptor (FcRn) is important for the metabolic fate of IgG antibodies in vivo. Analysis of the interaction between FcRn and IgG in vitro might provide insight into the structural and functional integrity of therapeutic IgG that may affect pharmacokinetics (PK) in vivo. We developed a standardized pH gradient FcRn affinity liquid chromatography method with conditions closely resembling the physiological mechanism of interaction between IgG and FcRn. This method allows the separation of molecular IgG isoforms, degradation products and engineered molecules based on their affinity to FcRn. Human FcRn was immobilized on the column and a linear pH gradient from pH 5.5 to 8.8 was applied. FcRn chromatography was used in comparison to surface plasmon resonance to characterize different monoclonal IgG preparations, e.g., oxidized or aggregated species. Wild-type and engineered IgGs were compared in vitro by FcRn chromatography and in vivo by PK studies in huFcRn transgenic mice. Analytical FcRn chromatography allows differentiation of IgG samples and variants by peak pattern and retention time profile. The method can distinguish: 1) IgGs with different Fabs, 2) oxidized from native IgG, 3) aggregates from monomer and 4) antibodies with mutations in the Fc part from wild-type IgGs. Changes in the FcRn chromatographic behavior of mutant IgGs relative to the wild-type IgG correlate to changes in the PK profile in the FcRn transgenic mice. These results demonstrate that FcRn affinity chromatography is a useful new method for the assessment of IgG integrity. PMID:23765230

  2. Pancreatitis Quality of Life Instrument: Development of a new instrument

    Directory of Open Access Journals (Sweden)

    Wahid Wassef

    2014-02-01

    Full Text Available Objectives: The goal of this project was to develop the first disease-specific instrument for the evaluation of quality of life in chronic pancreatitis. Methods: Focus groups and interview sessions were conducted, with chronic pancreatitis patients, to identify items felt to impact quality of life which were subsequently formatted into a paper-and-pencil instrument. This instrument was used to conduct an online survey by an expert panel of pancreatologists to evaluate its content validity. Finally, the modified instrument was presented to patients during precognitive testing interviews to evaluate its clarity and appropriateness. Results: In total, 10 patients were enrolled in the focus groups and interview sessions where they identified 50 items. Once redundant items were removed, the 40 remaining items were made into a paper-and-pencil instrument referred to as the Pancreatitis Quality of Life Instrument. Through the processes of content validation and precognitive testing, the number of items in the instrument was reduced to 24. Conclusions: This marks the development of the first disease-specific instrument to evaluate quality of life in chronic pancreatitis. It includes unique features not found in generic instruments (economic factors, stigma, and spiritual factors. Although this marks a giant step forward, psychometric evaluation is still needed prior to its clinical use.

  3. Reactor instrumentation and control

    International Nuclear Information System (INIS)

    Wach, D.; Beraha, D.

    1980-01-01

    The methods for measuring radiation are shortly reviewed. The instrumentation for neutron flux measurement is classified into out-of-core and in-core instrumentation. The out-of-core instrumentation monitors the operational range from the subcritical reactor to full power. This large range is covered by several measurement channels which derive their signals from counter tubes and ionization chambers. The in-core instrumentation provides more detailed information on the power distribution in the core. The self-powered neutron detectors and the aeroball system in PWR reactors are discussed. Temperature and pressure measurement devices are briefly discussed. The different methods for leak detection are described. In concluding the plant instrumentation part some new monitoring systems and analysis methods are presented: early failure detection methods by noise analysis, acoustic monitoring and vibration monitoring. The presentation of the control starts from an qualitative assessment of the reactor dynamics. The chosen control strategy leads to the definition of the part-load diagram, which provides the set-points for the different control systems. The tasks and the functions of these control systems are described. In additiion to the control, a number of limiting systems is employed to keep the reactor in a safe operating region. Finally, an outlook is given on future developments in control, concerning mainly the increased application of process computers. (orig./RW)

  4. Liquid chromatography tandem mass spectrometry method for simultaneous determination of metoprolol tartrate and ramipril in human plasma.

    Science.gov (United States)

    Gowda, K Veeran; Mandal, Uttam; Senthamil Selvan, P; Sam Solomon, W D; Ghosh, Animesh; Sarkar, Amlan Kanti; Agarwal, Sangita; Nageswar Rao, T; Pal, Tapan Kumar

    2007-10-15

    A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of metoprolol tartrate (MT) and ramipril, in human plasma. Both the drugs were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v). The chromatographic separation was performed on a reversed-phase C8 column with a mobile phase of 10 mM ammonium formate-methanol (3:97, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The method was validated over the concentration range of 5-500 ng/ml for metoprolol and ramipril in human plasma. The precursor to product ion transitions of m/z 268.0-103.10 and m/z 417.20-117.20 were used to measure metoprolol and ramipril, respectively.

  5. The Use of Gas Chromatography and Mass Spectrometry to Introduce General Chemistry Students to Percent Mass and Atomic Mass Calculations

    Science.gov (United States)

    Pfennig, Brian W.; Schaefer, Amy K.

    2011-01-01

    A general chemistry laboratory experiment is described that introduces students to instrumental analysis using gas chromatography-mass spectrometry (GC-MS), while simultaneously reinforcing the concepts of mass percent and the calculation of atomic mass. Working in small groups, students use the GC to separate and quantify the percent composition…

  6. A novel fast gas chromatography method for higher time resolution measurements of speciated monoterpenes in air

    Science.gov (United States)

    Jones, C. E.; Kato, S.; Nakashima, Y.; Kajii, Y.

    2014-05-01

    Biogenic emissions supply the largest fraction of non-methane volatile organic compounds (VOC) from the biosphere to the atmospheric boundary layer, and typically comprise a complex mixture of reactive terpenes. Due to this chemical complexity, achieving comprehensive measurements of biogenic VOC (BVOC) in air within a satisfactory time resolution is analytically challenging. To address this, we have developed a novel, fully automated Fast Gas Chromatography (Fast-GC) based technique to provide higher time resolution monitoring of monoterpenes (and selected other C9-C15 terpenes) during plant emission studies and in ambient air. To our knowledge, this is the first study to apply a Fast-GC based separation technique to achieve quantification of terpenes in ambient air. Three chromatography methods have been developed for atmospheric terpene analysis under different sampling scenarios. Each method facilitates chromatographic separation of selected BVOC within a significantly reduced analysis time compared to conventional GC methods, whilst maintaining the ability to quantify individual monoterpene structural isomers. Using this approach, the C9-C15 BVOC composition of single plant emissions may be characterised within a 14.5 min analysis time. Moreover, in-situ quantification of 12 monoterpenes in unpolluted ambient air may be achieved within an 11.7 min chromatographic separation time (increasing to 19.7 min when simultaneous quantification of multiple oxygenated C9-C10 terpenoids is required, and/or when concentrations of anthropogenic VOC are significant). These analysis times potentially allow for a twofold to fivefold increase in measurement frequency compared to conventional GC methods. Here we outline the technical details and analytical capability of this chromatographic approach, and present the first in-situ Fast-GC observations of 6 monoterpenes and the oxygenated BVOC (OBVOC) linalool in ambient air. During this field deployment within a suburban forest

  7. Enantioseparations in counter-current chromatography and centrifugal partition chromatography.

    Science.gov (United States)

    Foucault, A P

    2001-01-12

    Examples of chiral separations in counter-current chromatography (CCC) and centrifugal partition chromatography (CPC) are not numerous, due to the difficulty of finding chiral selectors highly selective in the liquid phase as well as a combination of solvents that does not destroy the selectivity and retains the capacity to elute chiral isomers of interest. New ideas and new chiral selectors generally come from other separation techniques, as will be highlighted in this review.

  8. Hydrophilic interaction liquid chromatography method for measuring the composition of aquatic humic substances

    KAUST Repository

    Wang, Renqi; Gutié rrez, Leonardo A.; Ng, Siuchoon; Croue, Jean-Philippe

    2015-01-01

    A hydrophilic interaction liquid chromatography (HILIC) method was developed to measure the composition of humic substances from river, reservoir, and treated wastewater based on their physicochemical properties. The current method fractionates the humic substances into four well-defined groups based on parallel analyses with a neutral and a cationic HILIC column, using mobile phases of varied compositions and pH. The results indicate that: (i) the proportion of carboxylic acids in the humic substances from terrestrial origins is less than half of that from treated wastewater (Jeddah, KSA), (ii) a higher content of basic compounds was observed in the humic substances from treated wastewater and Ribou Reservoir (Cholet, France) than in the sample from Loire River (France), (iii) a higher percentage of hydrophobic macromolecules were found in the humic substances from Loire River than in the other samples, and (iv) humic substances of treated wastewater contained less ionic neutral compounds (i.e., pKa 5-9) than the waters from terrestrial origins. The physicochemical property disparity amongst the compounds in each humic substances sample was also evaluated. The humic substances from the lightly humic Loire river displayed the highest disparity, whereas the highly humic Suwannee river (Georgia, USA) showed the most homogeneous humic substances.

  9. Hyphenated and comprehensive liquid chromatography × gas chromatography-mass spectrometry for the identification of Mycobacterium tuberculosis.

    Science.gov (United States)

    Mourão, Marta P B; Denekamp, Ilse; Kuijper, Sjoukje; Kolk, Arend H J; Janssen, Hans-Gerd

    2016-03-25

    Tuberculosis is one of the world's most emerging public health problems, particularly in developing countries. Chromatography based methods have been used to tackle this epidemic by focusing on biomarker detection. Unfortunately, interferences from lipids in the sputum matrix, particularly cholesterol, adversely affect the identification and detection of the marker compounds. The present contribution describes the serial combination of normal phase liquid chromatography (NPLC) with thermally assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) to overcome the difficulties of biomarker evaluation. The in-series combination consists of an LC analysis where fractions are collected and then transferred to the THM-GC-MS system. This was either done with comprehensive coupling, transferring all the fractions, or with hyphenated interfacing, i.e. off-line multi heart-cutting, transferring only selected fractions. Owing to the high sensitivity and selectivity of LC as a sample pre-treatment method, and to the high specificity of the MS as a detector, this analytical approach, NPLC × THM-GC-MS, is extremely sensitive. The results obtained indicate that this analytical set-up is able to detect down to 1 × 10(3) mycobacteria/mL of Mycobacterium tuberculosis strain 124, spiked in blank sputum samples. It is a powerful analytical tool and also has great potential for full automation. If further studies demonstrate its usefulness when applied blind in real sputum specimens, this technique could compete with the current smear microscopy in the early diagnosis of tuberculosis. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. A column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry method to determine anandamide and 2-arachidonoylglycerol in plasma samples.

    Science.gov (United States)

    Marchioni, Camila; de Souza, Israel Donizeti; Grecco, Caroline Fernandes; Crippa, José Alexandre; Tumas, Vitor; Queiroz, Maria Eugênia Costa

    2017-05-01

    This study reports a fast, sensitive, and selective column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method to determine the endocannabinoids (eCBs), anandamide (AEA), and 2-arachidonoylglycerol (2-AG) in plasma samples. This bidimensional system used a restricted access media column (RP-8 ADS, 25 mm × 4 mm × 25 μM) in the first dimension and a core-shell Kinetex C18 (100 mm × 2, 1.7 mm × 1 μM) column in the second dimension, followed by detection in a mass spectrometer triple quadrupole (multiple reactions monitoring mode) operating in the positive mode. RP-8 ADS was used for trace enrichment of eCBs (reverse phase partitioning) and macromolecular matrix size exclusion; the core-shell column was used for the chromatographic separation. The column switching UHPLC-MS/MS method presented a linear range spanning from 0.1 ng mL -1 (LOQ) to 6 ng mL -1 for AEA and from 0.04 ng mL -1 (LOQ) to 10 ng mL -1 for 2-AG. Excluding the LLOQ values, the precision assays provided coefficients of variation lower than 8% and accuracy with relative standard error values lower than 14%. Neither carryover nor matrix effects were detected. This high-throughput column switching method compared to conventional methods is time saving as it involves fewer steps, consumes less solvent, and presents lower LLOQ. The column switching UHPLC-MS/MS method was successfully applied to determine AEA and 2-AG in plasma samples obtained from Alzheimer's disease patients. Graphical abstract A column switching ultra high-performance liquid chromatography-tandem mass spectrometry method using RP-8 ADS column and core shell column to determine endocannabinoids in plasma samples.

  11. Development, validation, and application of a method for selected avermectin determination in rural waters using high performance liquid chromatography and fluorescence detection.

    Science.gov (United States)

    Lemos, Maria Augusta Travassos; Matos, Camila Alves; de Resende, Michele Fabri; Prado, Rachel Bardy; Donagemma, Raquel Andrade; Netto, Annibal Duarte Pereira

    2016-11-01

    Avermectins (AVM) are macrocyclic lactones used in livestock and agriculture. A quantitative method of high performance liquid chromatography with fluorescence detection for the determination of eprinomectin, abamectin, doramectin and ivermectin in rural water samples was developed and validated. The method was employed to study samples collected in the Pito Aceso River microbasin, located in the Bom Jardim municipality, Rio de Janeiro State, Brazil. Samples were extracted by solid phase extraction using a polymeric stationary phase, the eluted fraction was re-concentrated under a gentle N2 flow and derivatized to allow AVM determination using liquid chromatography with fluorescence detection. The excitation and emission wavelengths of the derivatives were 365 and 470nm, respectively, and a total chromatographic run of 12min was achieved. Very low limits of quantification (22-58ngL(-1)) were found after re-concentration using N2. Recovery values varied from 85.7% to 119.2% with standard deviations between 1.2% and 10.2%. The validated method was applied in the determination of AVM in 15 water samples collected in the Pito Aceso River microbasin, but most of them were free of AVM or showed only trace levels of these compounds, except for a sample that contained doramectin (9.11µgL(-1)). The method is suitable for routine analysis with satisfactory recovery, sensitivity, and selectivity. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Ion Chromatography-on-a-chip for Water Quality Analysis

    Science.gov (United States)

    Kidd, R. D.; Noell, A.; Kazarians, G.; Aubrey, A. D.; Scianmarello, N.; Tai, Y.-C.

    2015-01-01

    We report progress towards developing a Micro-Electro-Mechanical Systems (MEMS)- based ion chromatograph (IC) for crewed spacecraft water analysis. This IC-chip is an offshoot of a NASA-funded effort to produce a high performance liquid chromatograph (HPLC)-chip. This HPLC-chip system would require a desalting (i.e. ion chromatography) step. The complete HPLC instrument consists of the Jet Propulsion Labortory's (JPL's) quadrupole ion trap mass spectrometer integrated with a state-of-the-art MEMS liquid chromatograph (LC) system developed by the California Institute of Technology's (Caltech's) Micromachining Laboratory. The IC version of the chip consist of an electrolysis-based injector, a separation column, two electrolysis pumps for gradient generation, mixer, and a built-in conductivity detector. The HPLC version of the chip also includes a nanospray tip. The low instrument mass, coupled with its high analytical capabilities, makes the LC chip ideally suitable for wide range of applications such as trace contaminant, inorganic analytical science and, when coupled to a mass spectrometer, a macromolecular detection system for either crewed space exploration vehicles or robotic planetary missions.

  13. Fractionation of lithium isotopes in cation-exchange chromatography

    International Nuclear Information System (INIS)

    Oi, Takao; Kawada, Kazuhiko; Kakihana, Hidetake; Hosoe, Morikazu

    1991-01-01

    Various methods for lithium isotope separation have been developed, and their applicability to large-scale enriched lithium isotope production has been assessed. Ion-exchange chromatography is one such method. Cation-exchange chromatography of lithium was carried out to investigate the lithium isotope effect in aqueous ion-exchange systems. The heavier isotope. 7 Li, was preferentially fractionated into the resin phase in every experiment conducted, and this result is consistent with the results of previous work. The value of the separation factor was 1.00089-1.00171 at 25C. A comparison of lithium isotope effect with those of potassium and rubidium indicated that the isotope effect originating from hydration is larger than the effect due to phase change for lithium, while the opposite is the case with potassium and rubidium

  14. Calcium-sensitive immunoaffinity chromatography

    DEFF Research Database (Denmark)

    Henriksen, Maiken L; Lindhardt Madsen, Kirstine; Skjoedt, Karsten

    2014-01-01

    Immunoaffinity chromatography is a powerful fractionation technique that has become indispensable for protein purification and characterization. However, it is difficult to retrieve bound proteins without using harsh or denaturing elution conditions, and the purification of scarce antigens...... to homogeneity may be impossible due to contamination with abundant antigens. In this study, we purified the scarce, complement-associated plasma protein complex, collectin LK (CL-LK, complex of collectin liver 1 and kidney 1), by immunoaffinity chromatography using a calcium-sensitive anti-collectin-kidney-1 m...... chromatography was superior to the traditional immunoaffinity chromatographies and resulted in a nine-fold improvement of the purification factor. The technique is applicable for the purification of proteins in complex mixtures by single-step fractionation without the denaturation of eluted antigens...

  15. An improved pseudotargeted metabolomics approach using multiple ion monitoring with time-staggered ion lists based on ultra-high performance liquid chromatography/quadrupole time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yang; Liu, Fang; Li, Peng; He, Chengwei; Wang, Ruibing; Su, Huanxing; Wan, Jian-Bo, E-mail: jbwan@umac.mo

    2016-07-13

    Pseudotargeted metabolomics is a novel strategy integrating the advantages of both untargeted and targeted methods. The conventional pseudotargeted metabolomics required two MS instruments, i.e., ultra-high performance liquid chromatography/quadrupole-time- of-flight mass spectrometry (UHPLC/Q-TOF MS) and UHPLC/triple quadrupole mass spectrometry (UHPLC/QQQ-MS), which makes method transformation inevitable. Furthermore, the picking of ion pairs from thousands of candidates and the swapping of the data between two instruments are the most labor-intensive steps, which greatly limit its application in metabolomic analysis. In the present study, we proposed an improved pseudotargeted metabolomics method that could be achieved on an UHPLC/Q-TOF/MS instrument operated in the multiple ion monitoring (MIM) mode with time-staggered ion lists (tsMIM). Full scan-based untargeted analysis was applied to extract the target ions. After peak alignment and ion fusion, a stepwise ion picking procedure was used to generate the ion lists for subsequent single MIM and tsMIM. The UHPLC/Q-TOF tsMIM MS-based pseudotargeted approach exhibited better repeatability and a wider linear range than the UHPLC/Q-TOF MS-based untargeted metabolomics method. Compared to the single MIM mode, the tsMIM significantly increased the coverage of the metabolites detected. The newly developed method was successfully applied to discover plasma biomarkers for alcohol-induced liver injury in mice, which indicated its practicability and great potential in future metabolomics studies. - Highlights: • An UHPLC/Q-TOF tsMIM MS-based pseudotargeted metabolomics was proposed. • Compared to full scan, the improved method exhibits better repeatability and a wider linear range. • The proposed method could achieve pseudotargeted analysis on one UHPLC/Q-TOF/MS instrument. • The developed method was successfully used to discover biomarkers for alcohol-induced liver injury.

  16. An improved pseudotargeted metabolomics approach using multiple ion monitoring with time-staggered ion lists based on ultra-high performance liquid chromatography/quadrupole time-of-flight mass spectrometry

    International Nuclear Information System (INIS)

    Wang, Yang; Liu, Fang; Li, Peng; He, Chengwei; Wang, Ruibing; Su, Huanxing; Wan, Jian-Bo

    2016-01-01

    Pseudotargeted metabolomics is a novel strategy integrating the advantages of both untargeted and targeted methods. The conventional pseudotargeted metabolomics required two MS instruments, i.e., ultra-high performance liquid chromatography/quadrupole-time- of-flight mass spectrometry (UHPLC/Q-TOF MS) and UHPLC/triple quadrupole mass spectrometry (UHPLC/QQQ-MS), which makes method transformation inevitable. Furthermore, the picking of ion pairs from thousands of candidates and the swapping of the data between two instruments are the most labor-intensive steps, which greatly limit its application in metabolomic analysis. In the present study, we proposed an improved pseudotargeted metabolomics method that could be achieved on an UHPLC/Q-TOF/MS instrument operated in the multiple ion monitoring (MIM) mode with time-staggered ion lists (tsMIM). Full scan-based untargeted analysis was applied to extract the target ions. After peak alignment and ion fusion, a stepwise ion picking procedure was used to generate the ion lists for subsequent single MIM and tsMIM. The UHPLC/Q-TOF tsMIM MS-based pseudotargeted approach exhibited better repeatability and a wider linear range than the UHPLC/Q-TOF MS-based untargeted metabolomics method. Compared to the single MIM mode, the tsMIM significantly increased the coverage of the metabolites detected. The newly developed method was successfully applied to discover plasma biomarkers for alcohol-induced liver injury in mice, which indicated its practicability and great potential in future metabolomics studies. - Highlights: • An UHPLC/Q-TOF tsMIM MS-based pseudotargeted metabolomics was proposed. • Compared to full scan, the improved method exhibits better repeatability and a wider linear range. • The proposed method could achieve pseudotargeted analysis on one UHPLC/Q-TOF/MS instrument. • The developed method was successfully used to discover biomarkers for alcohol-induced liver injury.

  17. Improved methods for signal processing in measurements of mercury by Tekran® 2537A and 2537B instruments

    Science.gov (United States)

    Ambrose, Jesse L.

    2017-12-01

    Atmospheric Hg measurements are commonly carried out using Tekran® Instruments Corporation's model 2537 Hg vapor analyzers, which employ gold amalgamation preconcentration sampling and detection by thermal desorption (TD) and atomic fluorescence spectrometry (AFS). A generally overlooked and poorly characterized source of analytical uncertainty in those measurements is the method by which the raw Hg atomic fluorescence (AF) signal is processed. Here I describe new software-based methods for processing the raw signal from the Tekran® 2537 instruments, and I evaluate the performances of those methods together with the standard Tekran® internal signal processing method. For test datasets from two Tekran® instruments (one 2537A and one 2537B), I estimate that signal processing uncertainties in Hg loadings determined with the Tekran® method are within ±[1 % + 1.2 pg] and ±[6 % + 0.21 pg], respectively. I demonstrate that the Tekran® method can produce significant low biases (≥ 5 %) not only at low Hg sample loadings (< 5 pg) but also at tropospheric background concentrations of gaseous elemental mercury (GEM) and total mercury (THg) (˜ 1 to 2 ng m-3) under typical operating conditions (sample loadings of 5-10 pg). Signal processing uncertainties associated with the Tekran® method can therefore represent a significant unaccounted for addition to the overall ˜ 10 to 15 % uncertainty previously estimated for Tekran®-based GEM and THg measurements. Signal processing bias can also add significantly to uncertainties in Tekran®-based gaseous oxidized mercury (GOM) and particle-bound mercury (PBM) measurements, which often derive from Hg sample loadings < 5 pg. In comparison, estimated signal processing uncertainties associated with the new methods described herein are low, ranging from within ±0.053 pg, when the Hg thermal desorption peaks are defined manually, to within ±[2 % + 0.080 pg] when peak definition is automated. Mercury limits of detection (LODs

  18. Simple column-switching ion chromatography method for determining eight monosaccharides and oligosaccharides in honeydew and nectar.

    Science.gov (United States)

    Ni, Chengzhu; Zhu, Binhe; Wang, Nani; Wang, Muhua; Chen, Suqing; Zhang, Jiajie; Zhu, Yan

    2016-03-01

    Honeydew is excreted by aphids as a sweet waste and nectar is floral honey. Honeydew and nectar are complicated samples which consist of various sugars and amino acids. In this work, a simple ion chromatography with column-switching method was developed for the simultaneous analysis of 8 monosaccharides and oligosaccharides in honeydew and nectar. A reversed-phase column was used as a pretreatment column to eliminate organics on-line and sugars were eluted from a collection loop to analytical column by using column-switching technique. This method showed good linearity (r⩾0.9994) and afforded low limits of detection ranging from 1.55 to 10.17μgL(-1) for all the analytes. Recoveries ranged from 95% to 105% and repeatability results were acceptable with relative standard deviation of less than 3.21% (n=6). This method was successfully applied to quantification of these sugars in honeydew and nectar. These results showed honeydew had much more oligosaccharides than nectar. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Mars Geochemical Instrument (MarGI): An instrument for the analysis of the Martian surface and the search for evidence of life

    Science.gov (United States)

    Kojiro, Daniel R.; Mancinelli, Rocco; Martin, Joe; Holland, Paul M.; Stimac, Robert M.; Kaye, William J.

    2005-01-01

    The Mars Geochemical Instrument, MarGI, was developed to provide a comprehensive analysis of the rocks and surface material on Mars. The instrument combines Differential Thermal Analysis (DTA) with miniature Gas Chromatography-Ion Mobility Spectrometry (GC-IMS) to identify minerals, the presence and state of water, and organic compounds. Miniature pyrolysis ovens are used to both, conduct DTA analysis of soil or crushed rocks samples, and pyrolyze the samples at temperatures up to 1000 degrees C for GC-IMS analysis of the released gases. This combination of analytical processes and techniques, which can characterize the mineralogy of the rocks and soil, and identify and quantify volatiles released during pyrolysis, has applications across a wide range of target sites including comets, planets, asteroids, and moons such as Titan and Europa. The MarGI analytical approach evolved from the Cometary Ice and Dust Experiment (CIDEX) selected to fly on the Comet Rendezvous Asteroid Flyby Mission (CRAF).

  20. Determination of pesticides and pesticide degradates in filtered water by direct aqueous-injection liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    Sandstrom, Mark W.; Kanagy, Leslie K.; Anderson, Cyrissa A.; Kanagy, Christopher J.

    2016-01-11

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for determination of 229 pesticides compounds (113 pesticides and 116 pesticide degradates) in filtered water samples from stream and groundwater sites. The pesticides represent a broad range of chemical classes and were selected based on criteria such as current-use intensity, probability of occurrence in streams and groundwater, and toxicity to humans or aquatic organisms. More than half of the analytes are pesticide degradates. The method involves direct injection of a 100-microliter (μL) sample onto the LC-MS/MS without any sample preparation other than filtration. Samples are analyzed with two injections, one in electrospray ionization (ESI) positive mode and one in ESI negative mode, using dynamic multiple reaction monitoring (MRM) conditions, with two MRM transitions for each analyte. The LC-MS/MS instrument parameters were optimized for highest sensitivity for the most analytes. This report describes the analytical method and presents characteristics of the method validation including bias and variability, detection levels, and holding-time studies.

  1. Gas chromatography of β-diketonates

    International Nuclear Information System (INIS)

    Burgett, C.A.

    1976-01-01

    The history of separation of metal complexes by gas chromatography is reviewed. The greatest success has been achieved with metal halides or metal β-diketonates, particularly with chelates of the small elements, Be and Al, and the extremely inert chromium diketonates. Many problems still remain concerning the development of suitable chromatographic techniques for many chelates; however, the technique of synergic solvent extraction, mixed-ligand complex chromatography, the synthesis of new heteroatomic ligands, and the advent of new liquid phases are discussed as means to increase the number of unique techniques for separation and analysis of metals. Methods are suggested and references are cited for chromatographic analysis of elements in the following groups: alkali metals, alkaline earths, Group IIIA, IVB, VB, VIB, VIIB, VIII, IB, and IIB. Special attention is given to separation of the volatile complexes of Sc, Y, the lanthanides, the actinides, and Pb. 156 references

  2. A new liquid chromatography - tandem mass spectrometry method using atmospheric pressure photo ionization for the simultaneous determination of azaarenes and azaarones in Dutch river sediments

    NARCIS (Netherlands)

    Brulik, J.; Simek, Z.; de Voogt, P.

    2013-01-01

    A new method for the analysis of azaarenes and their degradation products (azaarones) was developed, optimized and validated using liquid chromatography coupled with atmospheric pressure photo ionization tandem mass spectrometric detection (LC-APPI/MS/MS). Seventeen compounds including 4 PAHs

  3. Low-Dimensional Feature Representation for Instrument Identification

    Science.gov (United States)

    Ihara, Mizuki; Maeda, Shin-Ichi; Ikeda, Kazushi; Ishii, Shin

    For monophonic music instrument identification, various feature extraction and selection methods have been proposed. One of the issues toward instrument identification is that the same spectrum is not always observed even in the same instrument due to the difference of the recording condition. Therefore, it is important to find non-redundant instrument-specific features that maintain information essential for high-quality instrument identification to apply them to various instrumental music analyses. For such a dimensionality reduction method, the authors propose the utilization of linear projection methods: local Fisher discriminant analysis (LFDA) and LFDA combined with principal component analysis (PCA). After experimentally clarifying that raw power spectra are actually good for instrument classification, the authors reduced the feature dimensionality by LFDA or by PCA followed by LFDA (PCA-LFDA). The reduced features achieved reasonably high identification performance that was comparable or higher than those by the power spectra and those achieved by other existing studies. These results demonstrated that our LFDA and PCA-LFDA can successfully extract low-dimensional instrument features that maintain the characteristic information of the instruments.

  4. Screening antiallergic components from Carthamus tinctorius using rat basophilic leukemia 2H3 cell membrane chromatography combined with high-performance liquid chromatography and tandem mass spectrometry.

    Science.gov (United States)

    Han, Shengli; Huang, Jing; Cui, Ronghua; Zhang, Tao

    2015-02-01

    Carthamus tinctorius, used in traditional Chinese medicine, has many pharmacological effects, such as anticoagulant effects, antioxidant effects, antiaging effects, regulation of gene expression, and antitumor effects. However, there is no report on the antiallergic effects of the components in C. tinctorius. In the present study, we investigated the antiallergic components of C. tinctorius and its mechanism of action. A rat basophilic leukemia 2H3/cell membrane chromatography coupled online with high-performance liquid chromatography and tandem mass spectrometry method was developed to screen antiallergic components from C. tinctorius. The screening results showed that Hydroxysafflor yellow A, from C. tinctorius, was the targeted component that retained on the rat basophilic leukemia 2H3/cell membrane chromatography column. We measured the amount of β-hexosaminidase and histamine released in mast cells and the key markers of degranulation. The release assays showed that Hydroxysafflor yellow A could attenuate the immunoglobulin E induced release of allergic cytokines without affecting cell viability from 1.0 to 50.0 μM. In conclusion, the established rat basophilic leukemia 2H3 cell membrane chromatography coupled with online high-performance liquid chromatography and tandem mass spectrometry method successfully screened and identified Hydroxysafflor yellow A from C. tinctorius as a potential antiallergic component. Pharmacological analysis elucidated that Hydroxysafflor yellow A is an effective natural component for inhibiting immunoglobulin E-antigen-mediated degranulation. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Screening of extraction methods for glycoproteins from jellyfish ( Rhopilema esculentum) oral-arms by high performance liquid chromatography

    Science.gov (United States)

    Ren, Guoyan; Li, Bafang; Zhao, Xue; Zhuang, Yongliang; Yan, Mingyan; Hou, Hu; Zhang, Xiukun; Chen, Li

    2009-03-01

    In order to select an optimum extraction method for the target glycoprotein (TGP) from jellyfish ( Rhopilema esculentum) oral-arms, a high performance liquid chromatography (HPLC)-assay for the determination of the TGP was developed. Purified target glycoprotein was taken as a standard glycoprotein. The results showed that the calibration curves for peak area plotted against concentration for TGP were linear ( r = 0.9984, y = 4.5895 x+47.601) over concentrations ranging from 50 to 400 mgL-1. The mean extraction recovery was 97.84% (CV2.60%). The fractions containing TGP were isolated from jellyfish ( R. esculentum) oral-arms by four extraction methods: 1) water extraction (WE), 2) phosphate buffer solution (PBS) extraction (PE), 3) ultrasound-assisted water extraction (UA-WE), 4) ultrasound-assisted PBS extraction (UA-PE). The lyophilized extract was dissolved in Milli-Q water and analyzed directly on a short TSK-GEL G4000PWXL (7.8 mm×300 mm) column. Our results indicated that the UA-PE method was the optimum extraction method selected by HPLC.

  6. RNase-assisted RNA chromatography

    Science.gov (United States)

    Michlewski, Gracjan; Cáceres, Javier F.

    2010-01-01

    RNA chromatography combined with mass spectrometry represents a widely used experimental approach to identify RNA-binding proteins that recognize specific RNA targets. An important drawback of most of these protocols is the high background due to direct or indirect nonspecific binding of cellular proteins to the beads. In many cases this can hamper the detection of individual proteins due to their low levels and/or comigration with contaminating proteins. Increasing the salt concentration during washing steps can reduce background, but at the cost of using less physiological salt concentrations and the likely loss of important RNA-binding proteins that are less stringently bound to a given RNA, as well as the disassembly of protein or ribonucleoprotein complexes. Here, we describe an improved RNA chromatography method that relies on the use of a cocktail of RNases in the elution step. This results in the release of proteins specifically associated with the RNA ligand and almost complete elimination of background noise, allowing a more sensitive and thorough detection of RNA-binding proteins recognizing a specific RNA transcript. PMID:20571124

  7. New ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of irbesartan in human plasma

    Directory of Open Access Journals (Sweden)

    Tanveer A. Wani

    2015-09-01

    Full Text Available With the objective of reducing analysis time and maintaining good efficiency, there has been substantial focus on high-speed chromatographic separations and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS is a preeminent analytical tool for rapid biomedical analysis. In this study a simple, rapid, sensitive, and specific ultra-performance liquid chromatography-MS/MS method was developed and validated for quantification of the angiotensin II receptor antagonist, irbesartan (IRB, in human plasma. After a simple protein precipitation using methanol and acetonitrile, IRB and internal standard (IS telmisartan were separated on Acquity UPLC BEH C18 column (50 mm × 2.1 mm, i.d. 1.7 μm, Waters, Milford, MA, USA using a mobile phase consisted of acetonitrile: methanol: 10 mM ammonium acetate (70: 15: 15 v/v/v with a flow rate of 0.4 mL/min and detected MS/MS in negative ion mode. The ion transitions recorded in multiple reaction monitoring mode were m/z 427.2→193.08 for IRB and m/z 513.2→469.3 for IS. The assay exhibited a linear dynamic range of 2–500 ng/mL for IRB in human plasma with good correlation coefficient of (0.995 and with a lower limit of quantitation of 2 ng/mL. The intra- and interassay precisions were satisfactory; the relative standard deviations did not exceed 9.91%. The proposed UPLC-MS/MS method is simple, rapid, and highly sensitive, and hence it could be reliable for pharmacokinetic and toxicokinetic study in both animals and humans.

  8. An improved pseudotargeted metabolomics approach using multiple ion monitoring with time-staggered ion lists based on ultra-high performance liquid chromatography/quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Wang, Yang; Liu, Fang; Li, Peng; He, Chengwei; Wang, Ruibing; Su, Huanxing; Wan, Jian-Bo

    2016-07-13

    Pseudotargeted metabolomics is a novel strategy integrating the advantages of both untargeted and targeted methods. The conventional pseudotargeted metabolomics required two MS instruments, i.e., ultra-high performance liquid chromatography/quadrupole-time- of-flight mass spectrometry (UHPLC/Q-TOF MS) and UHPLC/triple quadrupole mass spectrometry (UHPLC/QQQ-MS), which makes method transformation inevitable. Furthermore, the picking of ion pairs from thousands of candidates and the swapping of the data between two instruments are the most labor-intensive steps, which greatly limit its application in metabolomic analysis. In the present study, we proposed an improved pseudotargeted metabolomics method that could be achieved on an UHPLC/Q-TOF/MS instrument operated in the multiple ion monitoring (MIM) mode with time-staggered ion lists (tsMIM). Full scan-based untargeted analysis was applied to extract the target ions. After peak alignment and ion fusion, a stepwise ion picking procedure was used to generate the ion lists for subsequent single MIM and tsMIM. The UHPLC/Q-TOF tsMIM MS-based pseudotargeted approach exhibited better repeatability and a wider linear range than the UHPLC/Q-TOF MS-based untargeted metabolomics method. Compared to the single MIM mode, the tsMIM significantly increased the coverage of the metabolites detected. The newly developed method was successfully applied to discover plasma biomarkers for alcohol-induced liver injury in mice, which indicated its practicability and great potential in future metabolomics studies. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Determination of thyroid hormones in mouse tissues by isotope-dilution microflow liquid chromatography-mass spectrometry method

    DEFF Research Database (Denmark)

    De Angelis, Meri; Giesert, Florian; Finan, Brian

    2016-01-01

    ). The nano-UPLC system was interfaced with a quadrupole time-of-flight mass spectrometer (Q-TOF2-MS) using the positive ion mode electrospray ionization. In our analytical method the instrumental calibration curves were constructed from 0 to 100pgμL(-1) and all of them showed good linearity (r(2)>0.99...

  10. Advances in silver ion chromatography for the analysis of fatty acids and triacylglycerols-2001 to 2011.

    Science.gov (United States)

    Momchilova, Svetlana M; Nikolova-Damyanova, Boryana M

    2012-01-01

    An effort is made to critically present the achievements in silver ion chromatography during the last decade. Novelties in columns, mobile-phase compositions and detectors are described. Recent applications of silver ion chromatography in the analysis of fatty acids and triacylglycerols are presented while stressing novel analytical strategies or new objects. The tendencies in the application of the method in complementary ways with reversed-phase chromatography, chiral chromatography and, especially, mass detection are outlined.

  11. Bayesian approach for peak detection in two-dimensional chromatography

    NARCIS (Netherlands)

    Vivó-Truyols, G.

    2012-01-01

    A new method for peak detection in two-dimensional chromatography is presented. In a first step, the method starts with a conventional one-dimensional peak detection algorithm to detect modulated peaks. In a second step, a sophisticated algorithm is constructed to decide which of the individual

  12. Ultrahigh performance supercritical fluid chromatography of lipophilic compounds with application to synthetic and commercial biodiesel.

    Science.gov (United States)

    Ashraf-Khorassani, M; Yang, J; Rainville, P; Jones, M D; Fountain, K J; Isaac, G; Taylor, L T

    2015-03-01

    Ultrahigh performance supercritical fluid chromatography (UHPSFC) in combination with sub-2μm particles and either diode array ultraviolet (UV), evaporative light scattering, (ELSD), or mass spectrometric (MS) detection has been shown to be a valuable technique for the determination of acylglycerols in soybean, corn, sesame, and tobacco seed oils. Excellent resolution on an un-endcapped single C18 column (3.0mm×150mm) with a mobile phase gradient of acetonitrile and carbon dioxide in as little as 10min served greatly as an improvement on first generation packed column SFC instrumentation. Unlike high resolution gas chromatography and high performance liquid chromatography with mass spectrometric detection, UHPSFC/MS was determined to be a superior analytical tool for both separation and detection of mono-, di-, and tri-acylglycerols as well as free glycerol itself in biodiesel without derivatization. Baseline separation of residual tri-, di-, and mono-acylglycerols alongside glycerol at 0.05% (w/w) was easily obtained employing packed column SFC. The new analytical methodology was applied to both commercial B100 biodiesel (i.e. fatty acid methyl esters) derived from vegetable oil and to an "in-house" synthetic biodiesel (i.e. fatty acid ethyl esters) derived from tobacco seed oil and ethanol both before and after purification via column chromatography on bare silica. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Comparison of methods and instruments for 222Rn/220Rn progeny measurement

    International Nuclear Information System (INIS)

    Liu Yanyang; Shang Bing; Wu Yunyun; Zhou Qingzhi

    2012-01-01

    In this paper, comparisons were made among three methods of measurement (grab measurement, continuous measurement and integrating measurement) and also measurement of different instruments for a radon/thoron mixed chamber. Taking the optimized five-segment method as a comparison criterion, for the equilibrium-equivalent concentration of 222 Rn, measured results of Balm and 24 h integrating detectors are 31% and 29% higher than the criterion, the results of Wl x, however, is 20% lower; and for 220 Rn progeny, the results of Fiji-142, Kf-602D, BWLM and 24 h integrating detector are 86%, 18%, 28% and 36% higher than the criterion respectively, except that of WLx, which is 5% lower. For the differences shown, further research is needed. (authors)

  14. Comparison of burnup methods for (Th,U)O2 fuel

    International Nuclear Information System (INIS)

    Green, L.W.; Cassidy, R.M.; Edwards, W.J.; Knight, C.H.

    1983-01-01

    Analysis methods based on thermal ionisation mass spectrometry (TIMS), high performance liquid chromatography (HPLC) and instrumental neutron activation (INA) were investigated. Fission products 139 La, 140 Ce, 142 Ce, 145+146 Nd and the sum of the major lanthanides (masses 139 to 152) were evaluated as fission monitors. A TIMS- 145+146 Nd method was selected as a reference method, and a HPLC- 139 La method showed good agreement and similar precision. Results obtained by INA- 142 Ce, HPLC-(139-152) and TIMS-1 48 Nd methods showed significant differences from those obtained by the above two, for various reasons. The weight and initial composition of the fuel was shown to give a sufficiently accurate estimate of the initial heavy element content; this combined with the HPLC- 139 La method yielded a fast, low-cost burnup method. (author)

  15. Isotope dilution liquid chromatography - mass spectrometry methods for fat- and water-soluble vitamins in nutritional formulations.

    Science.gov (United States)

    Phinney, Karen W; Rimmer, Catherine A; Thomas, Jeanice Brown; Sander, Lane C; Sharpless, Katherine E; Wise, Stephen A

    2011-01-01

    Vitamins are essential to human health, and dietary supplements containing vitamins are widely used by individuals hoping to ensure they have adequate intake of these important nutrients. Measurement of vitamins in nutritional formulations is necessary to monitor regulatory compliance and in studies examining the nutrient intake of specific populations. Liquid chromatographic methods, primarily with UV absorbance detection, are well established for both fat- and water-soluble measurements, but they do have limitations for certain analytes and may suffer from a lack of specificity in complex matrices. Liquid chromatography-mass spectrometry (LC-MS) provides both sensitivity and specificity for the determination of vitamins in these matrices, and simultaneous analysis of multiple vitamins in a single analysis is often possible. In this work, LC-MS methods were developed for both fat- and water-soluble vitamins and applied to the measurement of these analytes in two NIST Standard Reference Materials. When possible, stable isotope labeled internal standards were employed for quantification.

  16. Safety operation of chromatography column system with discharging hydrogen radiolytically generated

    International Nuclear Information System (INIS)

    Watanabe, S; Sano, Y.; Nomura, K.; Koma, Y.; Okamoto, Y.

    2015-01-01

    The extraction chromatography technology is one of the promising methods for the partitioning of minor actinides (Am and Cm) from spent nuclear fuels. In the extraction chromatography system, the accumulation of hydrogen gas in the chromatography column is suspected to lead to fire or explosion. In order to prevent hazardous accidents, it is necessary to evaluate behaviors of gas radiolytically generated inside the column. In this study, behaviors of gas inside the extraction chromatography column were investigated through experiments and Computation Fluid Dynamics (CFD) simulation. N_2 gas once accumulated as bubbles in the packed bed was hardly discharged by the flow of mobile phase. However, the CFD simulation and X-ray imaging on γ-ray irradiated column revealed that during operation the hydrogen gas generated in the column was dissolved into the mobile phase without accumulation and then discharged. (authors)

  17. Cross validation of gas chromatography-flame photometric detection and gas chromatography-mass spectrometry methods for measuring dialkylphosphate metabolites of organophosphate pesticides in human urine.

    Science.gov (United States)

    Prapamontol, Tippawan; Sutan, Kunrunya; Laoyang, Sompong; Hongsibsong, Surat; Lee, Grace; Yano, Yukiko; Hunter, Ronald Elton; Ryan, P Barry; Barr, Dana Boyd; Panuwet, Parinya

    2014-01-01

    We report two analytical methods for the measurement of dialkylphosphate (DAP) metabolites of organophosphate pesticides in human urine. These methods were independently developed/modified and implemented in two separate laboratories and cross validated. The aim was to develop simple, cost effective, and reliable methods that could use available resources and sample matrices in Thailand and the United States. While several methods already exist, we found that direct application of these methods required modification of sample preparation and chromatographic conditions to render accurate, reliable data. The problems encountered with existing methods were attributable to urinary matrix interferences, and differences in the pH of urine samples and reagents used during the extraction and derivatization processes. Thus, we provide information on key parameters that require attention during method modification and execution that affect the ruggedness of the methods. The methods presented here employ gas chromatography (GC) coupled with either flame photometric detection (FPD) or electron impact ionization-mass spectrometry (EI-MS) with isotopic dilution quantification. The limits of detection were reported from 0.10ng/mL urine to 2.5ng/mL urine (for GC-FPD), while the limits of quantification were reported from 0.25ng/mL urine to 2.5ng/mL urine (for GC-MS), for all six common DAP metabolites (i.e., dimethylphosphate, dimethylthiophosphate, dimethyldithiophosphate, diethylphosphate, diethylthiophosphate, and diethyldithiophosphate). Each method showed a relative recovery range of 94-119% (for GC-FPD) and 92-103% (for GC-MS), and relative standard deviations (RSD) of less than 20%. Cross-validation was performed on the same set of urine samples (n=46) collected from pregnant women residing in the agricultural areas of northern Thailand. The results from split sample analysis from both laboratories agreed well for each metabolite, suggesting that each method can produce

  18. Effect of freezing method and frozen storage duration on instrumental quality of lamb throughout display.

    Science.gov (United States)

    Muela, E; Sañudo, C; Campo, M M; Medel, I; Beltrán, J A

    2010-04-01

    This study evaluated the effect of freezing method (FM) (air blast freezer, freezing tunnel, or nitrogen chamber) and frozen storage duration (FSD) (1, 3, or 6 months) on the instrumental measurements of quality of thawed lamb, aged for a total of 72 h, throughout a 10-d display period, compared to the quality of fresh meat. pH, colour, lipid oxidation, thawing, and cooking losses in Longissimus thoracis and lumborum muscle, were determined following standard methods. FM affected yellowness, FSD redness and thawing losses, and both affected oxidation (increased as freezing rate decreased and/or as storage duration increased). When compared with fresh meat, the main differences appeared on oxidation (where a significant interaction between treatment (3FM x 3FSD + fresh meat) with display duration was detected), and on total losses (thaw + cook losses). Oxidation was lower in fresh meat, but values were not significantly different from those stored frozen for 1 month. Fresh meat had smaller total losses than did thawed meat, but losses were not significantly different from meat frozen in the freezing tunnel and stored frozen for 1 month. Display duration had a greater effect on instrumental quality parameters than did FM or FSD. pH, b*, and oxidation increased, and L* and a* decreased with an increase in the number of days on display. In conclusion, neither freezing method nor frozen storage up to 6 months influenced extensively the properties of lamb when instrumental measurements of quality were measured in meat that had been displayed for 1d after thawing. The small deterioration shown in this study should not give consumers concerns about frozen meat. 2009 Elsevier Ltd. All rights reserved.

  19. Validation of a liquid chromatography method for the simultaneous determination of sulfadimethoxine and trimethoprim and application to a stability study.

    Science.gov (United States)

    Louati, K; Mistiri, F; Kallel, M; Safta, F

    2010-03-01

    A liquid chromatography method is described for the simultaneous determination of sulfadimetoxine and trimethoprim from a veterinary formulation at the proportion of 187 mg and 40 mg respectively in presence of some excipient. The solution was subjected to different International Conference On Harmonisation prescribed stress conditions (hydrolysis, oxidation and photolysis). A stability-indicating high-performance liquid chromatography method was developed for the analysis of active substances in presence of their major degradation products. It involved a Knauer Eurospher C18 thermostated column at 25 degrees C, and 9.57 mM phosphate buffer (pH adjusted to 2.0 with orthophosphoric acid)-acetonitrile (70:30 v/v) as mobile phase. The mobile phase flow rate and sample volume injected were 1.2 mL/min and 20 microL, respectively. The selected wavelength for the determination was 248 nm. The method was validated for linearity, precision, accuracy and specificity, and then applied to a stability study of sulfadimetoxine and trimethoprim in the veterinary solution packaged in high density polyethylene plastic bottles of 1 L and 100 mL thermosealed and no thermosealed and corked by a white cap, at both accelerated and long-term conditions required by the International Conference On Harmonisation. The method developed, which separates all of the most degradation products formed under variety of conditions, proved to be simple, accurate, precise and specific. The results of the stress degradation show that the solution is more sensitive to hydrolysis. The stability studies carried out on three batches of each presentation show that the finished product remains stable for six months. Copyright 2010 Elsevier Masson SAS. All rights reserved.

  20. Improved retrieval of cloud base heights from ceilometer using a non-standard instrument method

    Science.gov (United States)

    Wang, Yang; Zhao, Chuanfeng; Dong, Zipeng; Li, Zhanqing; Hu, Shuzhen; Chen, Tianmeng; Tao, Fa; Wang, Yuzhao

    2018-04-01

    Cloud-base height (CBH) is a basic cloud parameter but has not been measured accurately, especially under polluted conditions due to the interference of aerosol. Taking advantage of a comprehensive field experiment in northern China in which a variety of advanced cloud probing instruments were operated, different methods of detecting CBH are assessed. The Micro-Pulse Lidar (MPL) and the Vaisala ceilometer (CL51) provided two types of backscattered profiles. The latter has been employed widely as a standard means of measuring CBH using the manufacturer's operational algorithm to generate standard CBH products (CL51 MAN) whose quality is rigorously assessed here, in comparison with a research algorithm that we developed named value distribution equalization (VDE) algorithm. It was applied to both the profiles of lidar backscattering data from the two instruments. The VDE algorithm is found to produce more accurate estimates of CBH for both instruments and can cope with heavy aerosol loading conditions well. By contrast, CL51 MAN overestimates CBH by 400 m and misses many low level clouds under such conditions. These findings are important given that CL51 has been adopted operationally by many meteorological stations in China.