Sample records for chromatography method development

  1. Development of a high performance liquid chromatography method ...

    African Journals Online (AJOL)

    Development of a high performance liquid chromatography method for simultaneous ... Purpose: To develop and validate a new low-cost high performance liquid chromatography (HPLC) method for ..... Several papers have reported the use of ...

  2. Schinus terebinthifolius countercurrent chromatography (Part III): Method transfer from small countercurrent chromatography column to preparative centrifugal partition chromatography ones as a part of method development.

    Science.gov (United States)

    das Neves Costa, Fernanda; Hubert, Jane; Borie, Nicolas; Kotland, Alexis; Hewitson, Peter; Ignatova, Svetlana; Renault, Jean-Hugues

    2017-03-03

    Countercurrent chromatography (CCC) and centrifugal partition chromatography (CPC) are support free liquid-liquid chromatography techniques sharing the same basic principles and features. Method transfer has previously been demonstrated for both techniques but never from one to another. This study aimed to show such a feasibility using fractionation of Schinus terebinthifolius berries dichloromethane extract as a case study. Heptane - ethyl acetate - methanol -water (6:1:6:1, v/v/v/v) was used as solvent system with masticadienonic and 3β-masticadienolic acids as target compounds. The optimized separation methodology previously described in Part I and II, was scaled up from an analytical hydrodynamic CCC column (17.4mL) to preparative hydrostatic CPC instruments (250mL and 303mL) as a part of method development. Flow-rate and sample loading were further optimized on CPC. Mobile phase linear velocity is suggested as a transfer invariant parameter if the CPC column contains sufficient number of partition cells. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Theories to support method development in comprehensive two-dimensional liquid chromatography - A review

    NARCIS (Netherlands)

    Bedani, F.; Schoenmakers, P.J.; Janssen, H.-G.

    2012-01-01

    On-line comprehensive two-dimensional liquid chromatography techniques promise to resolve samples that current one-dimensional liquid chromatography methods cannot adequately deal with. To make full use of the potential of two-dimensional liquid chromatography, optimization is required. Optimization

  4. Development of a sensitive and rapid method for rifampicin impurity analysis using supercritical fluid chromatography.

    Science.gov (United States)

    Li, Wei; Wang, Jun; Yan, Zheng-Yu

    2015-10-10

    A novel simple, fast and efficient supercritical fluid chromatography (SFC) method was developed and compared with RPLC method for the separation and determination of impurities in rifampicin. The separation was performed using a packed diol column and a mobile phase B (modifier) consisting of methanol with 0.1% ammonium formate (w/v) and 2% water (v/v). Overall satisfactory resolutions and peak shapes for rifampicin quinone (RQ), rifampicin (RF), rifamycin SV (RSV), rifampicin N-oxide (RNO) and 3-formylrifamycinSV (3-FR) were obtained by optimization of the chromatography system. With gradient elution of mobile phase, all of the impurities and the active were separated within 4 min. Taking full advantage of features of SFC (such as particular selectivity, non-sloping baseline in gradient elution, and without injection solvent effects), the method was successfully used for determination of impurities in rifampicin, with more impurity peaks detected, better resolution achieved and much less analysis time needed compared with conventional reversed-phase liquid chromatography (RPLC) methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Development of high performance liquid chromatography method for miconazole analysis in powder sample

    Science.gov (United States)

    Hermawan, D.; Suwandri; Sulaeman, U.; Istiqomah, A.; Aboul-Enein, H. Y.

    2017-02-01

    A simple high performance liquid chromatography (HPLC) method has been developed in this study for the analysis of miconazole, an antifungal drug, in powder sample. The optimized HPLC system using C8 column was achieved using mobile phase composition containing methanol:water (85:15, v/v), a flow rate of 0.8 mL/min, and UV detection at 220 nm. The calibration graph was linear in the range from 10 to 50 mg/L with r 2 of 0.9983. The limit of detection (LOD) and limit of quantitation (LOQ) obtained were 2.24 mg/L and 7.47 mg/L, respectively. The present HPLC method is applicable for the determination of miconazole in the powder sample with a recovery of 101.28 % (RSD = 0.96%, n = 3). The developed HPLC method provides short analysis time, high reproducibility and high sensitivity.

  6. Liquid chromatography method development and optimization for valsartan: pharmacokinetics of oral hydrogels in rabbits

    International Nuclear Information System (INIS)

    Sohail, M.; Minhas, M.U.

    2017-01-01

    A simple, rapid, precise, accurate high performance liquid chromatography method has been developed and subsequently validated for determination of valsartan in rabbit plasma. The method was developed employing mixture of mobile phase consisting of 0.02 M potassium dihydrogen phosphate buffer and acetonitrile (45:55), pH was adjusted to 2.7 using 50% orthophosphoric acid and pumped thorough chromatographic system at a flow rate of 1 ml/min. An isocratic elution mode was carried out at HPLC system (Agilent Technologies, 1200 series, USA) fitted with variable wavelength detector and data processing software ChemStation. For sample analysis, 20 mul sample was injected and eluate was monitored at 225nm wavelength. Pharmacokinetic evaluation was performed in rabbits after the oral administration of valsartan loaded PVA-co-poly(AA) hydrogels. The mean Cmax of valsartan was 408.439ng/ml, Tmax was 12h and half life (t1/2) was 8.812h. The extraction procedure was simple with good response even at very low drug concentration, thereby making this method suitable for pharmacokinetic application. It is concluded that developed method is simple, fast, cost effective, and reproducible for the analysis of pharmacokinetic parameters in the rabbit plasma. (author)

  7. Development and validation of ultra-high performance supercritical fluid chromatography method for determination of illegal dyes and comparison to ultra-high performance liquid chromatography method.

    Science.gov (United States)

    Khalikova, Maria A; Šatínský, Dalibor; Solich, Petr; Nováková, Lucie

    2015-05-18

    A novel simple, fast and efficient ultra-high performance supercritical fluid chromatography (UHPSFC) method was developed and validated for the separation and quantitative determination of eleven illegal dyes in chili-containing spices. The method involved a simple ultrasound-assisted liquid extraction of illegal compounds with tetrahydrofuran. The separation was performed using a supercritical fluid chromatography system and CSH Fluoro-Phenyl stationary phase at 70°C. The mobile phase was carbon dioxide and the mixture of methanol:acetonitrile (1:1, v/v) with 2.5% formic acid as an additive at the flow rate 2.0 mL min(-1). The UV-vis detection was accomplished at 500 nm for seven compounds and at 420 nm for Sudan Orange G, Butter Yellow, Fast Garnet GBC and Methyl Red due to their maximum of absorbance. All eleven compounds were separated in less than 5 min. The method was successfully validated and applied using three commercial samples of chili-containing spices - Chili sauce (Indonesia), Feferony sauce (Slovakia) and Mojo sauce (Spain). The linearity range of proposed method was 0.50-9.09 mg kg(-1) (r ≥ 0.995). The detection limits were determined as signal to noise ratio of 3 and were ranged from 0.15 mg kg(-1) to 0.60 mg kg(-1) (1.80 mg kg(-1) for Fast Garnet) for standard solution and from 0.25 mg kg(-1) to 1.00 mg kg(-1) (2.50 mg kg(-1) for Fast Garnet, 1.50 mg kg(-1) for Sudan Red 7B) for chili-containing samples. The recovery values were in the range of 73.5-107.2% and relative standard deviation ranging from 0.1% to 8.2% for within-day precision and from 0.5% to 8.8% for between-day precision. The method showed potential for being used to monitor forbidden dyes in food constituents. The developed UHPSFC method was compared to the UHPLC-UV method. The orthogonality of Sudan dyes separation by these two methods was demonstrated. Benefits and drawbacks were discussed showing the reliability of both methods for monitoring of studied illegal dyes in real

  8. Development and validation of a thin-layer chromatography method for stability studies of naproxen

    International Nuclear Information System (INIS)

    Rodriguez Hernandez, Yaslenis; Suarez Perez, Yania; Garcia Pulpeiro, Oscar; Rodriguez Borges, Tania

    2011-01-01

    The validation of an analytical method was carried out to be applied to the stability studies of the future formulations of naproxen suppositories for infant and adult use. The factors which mostly influenced in the naproxen stability were determined, the major degradation occurred in oxidizing acid medium and by action of light. The possible formation of esters between the free carboxyl group present in naproxen and the glyceryl monoestereate present in the base was identified as one of the degradation paths in the new formulation. The results were satisfactory. A thin-layer chromatography-based method was developed as well as the best chromatographic conditions were selected. GF 254 silica gel plates and ultraviolet developer at 254 nm were employed. Three solvent systems were evaluated of which A made up of glacial acetic: tetrahydrofurane:toluene (3:9:90 v/v/v)allowed adequate resolution between the analyte and the possible degradation products, with detection limit of 1 μg. The use of the suggested method was restricted to the identification of possible degradation products just for qualitative purposes and not as final test. The method proved to be sensitive and selective enough to be applied for the stated objective, according to the validation results

  9. Development of an on-line mixed-mode gel liquid chromatography×reversed phase liquid chromatography method for separation of water extract from Flos Carthami.

    Science.gov (United States)

    Wang, Yu-Qing; Tang, Xu; Li, Jia-Fu; Wu, Yun-Long; Sun, Yu-Ying; Fang, Mei-Juan; Wu, Zhen; Wang, Xiu-Min; Qiu, Ying-Kun

    2017-10-13

    A novel on-line comprehensive two-dimensional liquid chromatography (2D-LC) method by coupling mixed-mode gel liquid chromatography (MMG-LC) with reversed phase liquid chromatography (RPLC) was developed. A mixture of 17 reference compounds was used to study the separation mechanism. A crude water extract of Flos Carthami was applied to evaluate the performance of the novel 2D-LC system. In the first dimension, the extract was eluted with a gradient of water/methanol over a cross-linked dextran gel Sephadex LH-20 column. Meanwhile, the advantages of size exclusion, reversed phase partition and adsorption separation mechanism were exploited before further on-line reversed phase purification on the second dimension. This novel on-line mixed-mode Sephadex LH-20×RPLC method provided higher peak resolution, sample processing ability (2.5mg) and better orthogonality (72.9%) versus RPLC×RPLC and hydrophilic interaction liquid chromatography (HILIC)×RPLC. To the best of our knowledge, this is the first report of a mixed-mode Sephadex LH-20×RPLC separation method with successful applications in on-line mode, which might be beneficial for harvesting targets from complicated medicinal plants. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Method Development for Pesticide Residue Analysis in Farmland Soil using High Perfomance Liquid Chromatography

    Science.gov (United States)

    Theresia Djue Tea, Marselina; Sabarudin, Akhmad; Sulistyarti, Hermin

    2018-01-01

    A method for the determination of diazinon and chlorantraniliprole in soil samples has been developed. The analyte was extracted with acetonitrile from farmland soil sample. Determination and quantification of diazinon and chlorantraniliprole were perfomed by high perfomance liquid chromatography (HPLC) with an UV detector. Several parameters of HPLC method were optimized with respect to sensitivity, high resolution of separation, and accurate determination of diazinon and chlorantraniliprole. Optimum conditions for the separation of two pesticides were eluent composition of acetonitrile:water ratio of 60:40, 0.4 mL/min of flow rate, and 220 nm of wavelength. Under the optimum conditions, diazinon linearity was in the range from 1-25 ppm with R2 of 0.9976, 1.19 mgL-1 LOD, and 3.98 mgL-1 LOQ; while the linearity of chlorantraniliprole was in the range from 0.2-5 mgL-1 with R2 of 0.9972, 0.39 mgL-1 LOD, and 1.29 mgL-1 LOQ. When the method was applied to the soil sample, both pesticides showed acceptable recoveries for real sample of more than 85%: thus, the developed method meets the validation requirement. Under this developed method, the concentrations of both pesticides in the soil samples were below the LOD and LOQ (0.577 mgL-1 for diazinon and 0.007 mgL-1 for chlorantraniliprole). Therefore, it can be concluded that the soil samples used in this study have neither diazinon nor chlorantraniliprole.

  11. Method developments approaches in supercritical fluid chromatography applied to the analysis of cosmetics.

    Science.gov (United States)

    Lesellier, E; Mith, D; Dubrulle, I

    2015-12-04

    Analyses of complex samples of cosmetics, such as creams or lotions, are generally achieved by HPLC. These analyses are often multistep gradients, due to the presence of compounds with a large range of polarity. For instance, the bioactive compounds may be polar, while the matrix contains lipid components that are rather non-polar, thus cosmetic formulations are usually oil-water emulsions. Supercritical fluid chromatography (SFC) uses mobile phases composed of carbon dioxide and organic co-solvents, allowing for good solubility of both the active compounds and the matrix excipients. Moreover, the classical and well-known properties of these mobile phases yield fast analyses and ensure rapid method development. However, due to the large number of stationary phases available for SFC and to the varied additional parameters acting both on retention and separation factors (co-solvent nature and percentage, temperature, backpressure, flow rate, column dimensions and particle size), a simplified approach can be followed to ensure a fast method development. First, suited stationary phases should be carefully selected for an initial screening, and then the other operating parameters can be limited to the co-solvent nature and percentage, maintaining the oven temperature and back-pressure constant. To describe simple method development guidelines in SFC, three sample applications are discussed in this paper: UV-filters (sunscreens) in sunscreen cream, glyceryl caprylate in eye liner and caffeine in eye serum. Firstly, five stationary phases (ACQUITY UPC(2)) are screened with isocratic elution conditions (10% methanol in carbon dioxide). Complementary of the stationary phases is assessed based on our spider diagram classification which compares a large number of stationary phases based on five molecular interactions. Secondly, the one or two best stationary phases are retained for further optimization of mobile phase composition, with isocratic elution conditions or, when

  12. Development of conjugate methods with gas chromatography for inorganic compounds analysis

    International Nuclear Information System (INIS)

    Baccan, N.

    1975-01-01

    The application of gas chromatography combined with mass spectrometry or with nuclear methods for the analysis of inorganic compounds is studied. The advantages of the use of a gas chromatograph coupled with a quadrupole mass spectrometer or with a high resolution radiation detector, are discussed. We also studied the formation and solvent extraction of metal chelates; an aliquot of the organic phase was directly injected into the gas chromatograph and the eluted compounds were detected by mass spectrometry or, when radioactive, by nuclear methods. (author)

  13. Gradient High Performance Liquid Chromatography Method ...

    African Journals Online (AJOL)

    Purpose: To develop a gradient high performance liquid chromatography (HPLC) method for the simultaneous determination of phenylephrine (PHE) and ibuprofen (IBU) in solid ..... nimesulide, phenylephrine. Hydrochloride, chlorpheniramine maleate and caffeine anhydrous in pharmaceutical dosage form. Acta Pol.

  14. Development and validation of high-performance liquid chromatography and high-performance thin-layer chromatography methods for the quantification of khellin in Ammi visnaga seed

    Science.gov (United States)

    Kamal, Abid; Khan, Washim; Ahmad, Sayeed; Ahmad, F. J.; Saleem, Kishwar

    2015-01-01

    Objective: The present study was used to design simple, accurate and sensitive reversed phase-high-performance liquid chromatography RP-HPLC and high-performance thin-layer chromatography (HPTLC) methods for the development of quantification of khellin present in the seeds of Ammi visnaga. Materials and Methods: RP-HPLC analysis was performed on a C18 column with methanol: Water (75: 25, v/v) as a mobile phase. The HPTLC method involved densitometric evaluation of khellin after resolving it on silica gel plate using ethyl acetate: Toluene: Formic acid (5.5:4.0:0.5, v/v/v) as a mobile phase. Results: The developed HPLC and HPTLC methods were validated for precision (interday, intraday and intersystem), robustness and accuracy, limit of detection and limit of quantification. The relationship between the concentration of standard solutions and the peak response was linear in both HPLC and HPTLC methods with the concentration range of 10–80 μg/mL in HPLC and 25–1,000 ng/spot in HPTLC for khellin. The % relative standard deviation values for method precision was found to be 0.63–1.97%, 0.62–2.05% in HPLC and HPTLC for khellin respectively. Accuracy of the method was checked by recovery studies conducted at three different concentration levels and the average percentage recovery was found to be 100.53% in HPLC and 100.08% in HPTLC for khellin. Conclusions: The developed HPLC and HPTLC methods for the quantification of khellin were found simple, precise, specific, sensitive and accurate which can be used for routine analysis and quality control of A. visnaga and several formulations containing it as an ingredient. PMID:26681890

  15. Analytical chromatography. Methods, instrumentation and applications

    International Nuclear Information System (INIS)

    Yashin, Ya I; Yashin, A Ya

    2006-01-01

    The state-of-the-art and the prospects in the development of main methods of analytical chromatography, viz., gas, high performance liquid and ion chromatographic techniques, are characterised. Achievements of the past 10-15 years in the theory and general methodology of chromatography and also in the development of new sorbents, columns and chromatographic instruments are outlined. The use of chromatography in the environmental control, biology, medicine, pharmaceutics, and also for monitoring the quality of foodstuffs and products of chemical, petrochemical and gas industries, etc. is considered.

  16. Amphenicols stability in medicated feed – development and validation of liquid chromatography method

    Directory of Open Access Journals (Sweden)

    Pietro Wojciech Jerzy

    2014-12-01

    Full Text Available A liquid chromatography-ultraviolet detection method for the determination of florfenicol (FF and thiamphenicol (TAP in feeds is presented. The method comprises the extraction of analytes from the matrix with a mixture of methanol and acetonitrile, drying of the extract, and its dissolution in phosphate buffer. The analysis was performed with a gradient programme of the mobile phase composed of acetonitrile and buffer (pH = 7.3 on a Zorbax Eclipse Plus C18 (150 × 4.6 mm, 5 μm analytical column with UV (λ = 220 nm detection. The analytical procedure has been successfully adopted and validated for quantitative determination of florfenicol and thiamphenicol in feed samples. Sensitivity, specificity, linearity, repeatability, and intralaboratory reproducibility were included in the validation. The mean recovery of amphenicols was 93.5% within the working range of 50-4000 mg/kg. Simultaneous determination of chloramphenicol, which is banned in the feed, was also included within the same procedure of FF and TAP stability studies. Storing the medicated feed at room temperature for up to one month decreased concentration in the investigated drugs even by 45%. These findings are relevant to successful provision of therapy to animals.

  17. Method development and validation for the determination of pesticides in green coffee by gas chromatography

    International Nuclear Information System (INIS)

    Dallos Corredor, David; Guerrero Dallos, Jairo Arturo

    2005-01-01

    This study describes the implementation and validation of a multiresidue methodology for the determination of organochlorine, organophosphorus and pyrethroids pesticides in green coffee. Pesticides residues were extracted from green samples with an acetone-water (2:1) mixture followed by ethyl acetate cyclohexane (1:1) partitioning. The clean up steps include gel permeation chromatography and mini column chromatography using silica gel. Final determination was carried out by high-resolution gas chromatography with a pulsed split less injection mode and simultaneous detection by μ-ECD and NPD coupled in parallel. The methodology is specific, selective precise and accurate. Recoveries of majority of pesticides from spiked samples range from 70 to 110% at fortification levels of 0.038 mg/kg-1.536 mg/kg with limit of quantitation between 0.011 mg/kg and 0.100 mg/kg

  18. COMPUTER-ASSISTED HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY METHOD DEVELOPMENT WITH APPLICATIONS TO THE ISOLATION AND ANALYSIS OF PHYTOPLANKTON PIGMENTS. (R826944)

    Science.gov (United States)

    We used chromatography modeling software to assist in HPLC method development, with the goalof enhancing separations through the exclusive use of gradient time and column temperature. Wesurveyed nine stationary phases for their utility in pigment purification and natur...

  19. Validated High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, rapid and sensitive high performance liquid chromatography (HPLC) method for the determination of cefadroxil monohydrate in human plasma. Methods: Schimadzu HPLC with LC solution software was used with Waters Spherisorb, C18 (5 μm, 150mm × 4.5mm) column. The mobile phase ...

  20. Quality by Design in the development of hydrophilic interaction liquid chromatography method with gradient elution for the analysis of olanzapine.

    Science.gov (United States)

    Tumpa, Anja; Stajić, Ana; Jančić-Stojanović, Biljana; Medenica, Mirjana

    2017-02-05

    This paper deals with the development of hydrophilic interaction liquid chromatography (HILIC) method with gradient elution, in accordance with Analytical Quality by Design (AQbD) methodology, for the first time. The method is developed for olanzapine and its seven related substances. Following step by step AQbD methodology, firstly as critical process parameters (CPPs) temperature, starting content of aqueous phase and duration of linear gradient are recognized, and as critical quality attributes (CQAs) separation criterion S of critical pairs of substances are investigated. Rechtschaffen design is used for the creation of models that describe the dependence between CPPs and CQAs. The design space that is obtained at the end is used for choosing the optimal conditions (set point). The method is fully validated at the end to verify the adequacy of the chosen optimal conditions and applied to real samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Development of a Method for Rapid Determination of Morpholine in Juices and Drugs by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Mengsi Cao

    2018-01-01

    Full Text Available A reliable derivatization method has been developed to detect and quantify morpholine in apple juices and ibuprofen with gas chromatography-mass spectrometry. Morpholine can react with sodium nitrite under acidic condition to produce stable and volatile N-nitrosomorpholine derivative. In this experiment, various factors affecting the derivatization and extraction process were optimized, including volume and concentration of hydrochloric acid, quantity of sodium nitrite, derivatization temperature, derivatization time, extraction reagents, and extraction time. The derivative was extracted with dichloromethane and determined by gas chromatography-mass spectrometry. The linearity range of morpholine was 10–500 μg·L−1 with good correlation, and limits of detection (LOD and limits of quantification (LOQ were 7.3 μg·L−1 and 24.4 μg·L−1, respectively. Low, medium, and high concentrations of morpholine were added in apple juices and ibuprofen samples to evaluate standard recovery rate and relative standard deviation. The spiked recovery rate ranged from 94.3% to 109.0%, and the intraday repeatability and interday reproducibility were 2.0%–4.4% and 3.3%–7.0%, respectively. The developed method has good accuracy and precision. This quantitative method for morpholine is simple, sensitive, rapid, and low cost and can successfully be applied to analyze the residual morpholine in apple juices and drug samples.

  2. Method Development and Validation for the Determination of Caffeine: An Alkaloid from Coffea arabica by High-performance Liquid Chromatography Method.

    Science.gov (United States)

    Naveen, P; Lingaraju, H B; Deepak, M; Medhini, B; Prasad, K Shyam

    2018-01-01

    The present study was investigated to develop and validate a reversed phase high performance liquid chromatography method for the determination of caffeine from bean material of Coffee arabica. The separation was achieved on a reversed-phase C18 column using a mobile phase composed of water: methanol (50:50) at a flow rate of 1.0 mlmin-1. The detection was carried out on a UV detector at 272 nm. The developed method was validated according to the requirements for International Conference on Harmonisation (ICH) guidelines, which includes specificity, linearity, precision, accuracy, limit of detection and limit of quantitation. The developed method validates good linearity with excellent correlation coefficient (R2 > 0.999). In repeatability and intermediate precision, the percentage relative standard deviation (% RSD) of peak area was less than 1% shows high precision of the method. The recovery rate for caffeine was within 98.78% - 101.28% indicates high accuracy of the method. The low limit of detection and limit of quantitation of caffeine enable the detection and quantitation of caffeine from C. arabica at low concentrations. The developed HPLC method is a simple, rapid, precisely, accurately and widely accepted and it is recommended for efficient assays in routine work. A simple, accurate, and sensitive high-performance liquid chromatography (HPLC) method for caffeine from Coffea arabica has been developed and validated. The developed HPLC method was validated for linearity, specificity, precision, recovery, limits of detection, and limits of quantification by the International Conference on Harmonization guidelines. The results revealed that the proposed method is highly reliable. This method could be successfully applied for routine quality work analysis. Abbreviation Used: C. arabica : Coffee arabica, ICH: International Conference on Harmonisation, % RSD: Percentage Relative Standard Deviation, R2: Correlation Coefficient, ppm: Parts per million, LOD: Limits

  3. Development and Validation of High Performance Liquid Chromatography Method for Determination Atorvastatin in Tablet

    Science.gov (United States)

    Yugatama, A.; Rohmani, S.; Dewangga, A.

    2018-03-01

    Atorvastatin is the primary choice for dyslipidemia treatment. Due to patent expiration of atorvastatin, the pharmaceutical industry makes copy of the drug. Therefore, the development methods for tablet quality tests involving atorvastatin concentration on tablets needs to be performed. The purpose of this research was to develop and validate the simple atorvastatin tablet analytical method by HPLC. HPLC system used in this experiment consisted of column Cosmosil C18 (150 x 4,6 mm, 5 µm) as the stationary reverse phase chomatography, a mixture of methanol-water at pH 3 (80:20 v/v) as the mobile phase, flow rate of 1 mL/min, and UV detector at wavelength of 245 nm. Validation methods were including: selectivity, linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). The results of this study indicate that the developed method had good validation including selectivity, linearity, accuracy, precision, LOD, and LOQ for analysis of atorvastatin tablet content. LOD and LOQ were 0.2 and 0.7 ng/mL, and the linearity range were 20 - 120 ng/mL.

  4. Multiple responses optimization in the development of a headspace gas chromatography method for the determination of residual solvents in pharmaceuticals

    Directory of Open Access Journals (Sweden)

    Carla M. Teglia

    2015-10-01

    Full Text Available An efficient generic static headspace gas chromatography (HSGC method was developed, optimized and validated for the routine determination of several residual solvents (RS in drug substance, using a strategy with two sets of calibration. Dimethylsulfoxide (DMSO was selected as the sample diluent and internal standards were used to minimize signal variations due to the preparative step. A gas chromatograph from Agilent Model 6890 equipped with flame ionization detector (FID and a DB-624 (30 m×0.53 mm i.d., 3.00 µm film thickness column was used. The inlet split ratio was 5:1. The influencing factors in the chromatographic separation of the analytes were determined through a fractional factorial experimental design. Significant variables: the initial temperature (IT, the final temperature (FT of the oven and the carrier gas flow rate (F were optimized using a central composite design. Response transformation and desirability function were applied to find out the optimal combination of the chromatographic variables to achieve an adequate resolution of the analytes and short analysis time. These conditions were 30 °C for IT, 158 °C for FT and 1.90 mL/min for F. The method was proven to be accurate, linear in a wide range and very sensitive for the analyzed solvents through a comprehensive validation according to the ICH guidelines. Keywords: Headspace gas chromatography, Residual solvents, Pharmaceuticals, Surface response methodology, Desirability function

  5. Development of a sample preparation method for the analysis of current-use pesticides in sediment using gas chromatography.

    Science.gov (United States)

    Wang, Dongli; Weston, Donald P; Ding, Yuping; Lydy, Michael J

    2010-02-01

    Pyrethroid insecticides have been implicated as the cause of sediment toxicity to Hyalella azteca in both agricultural and urban areas of California; however, for a subset of these toxic sediments (approximately 30%), the cause of toxicity remains unidentified. This article describes the analytical method development for seven additional pesticides that are being examined to determine if they might play a role in the unexplained toxicity. A pressurized liquid extraction method was optimized to simultaneously extract diazinon, methyl parathion, oxyfluorfen, dicofol, fenpropathrin, pyraclostrobin, and indoxacarb from sediment, and the extracts were cleaned using a two-step solid-phase extraction procedure. The final extract was analyzed for the target pesticides by gas chromatography/nitrogen-phosphorus detector (GC/NPD), and gas chromatography/electron capture detector (GC/ECD), after sulfur was removed by shaking with copper and cold crystallization. Three sediments were used as reference matrices to assess method accuracy and precision. Method detection limits were 0.23-1.8 ng/g dry sediment using seven replicates of sediment spiked at 1.0 ng/g dry sediment. Recoveries ranged from 61.6 to 118% with relative standard deviations of 2.1-17% when spiked at 5.0 and 50 ng/g dry sediment. The three reference sediments, spiked with 50 ng/g dry weight of the pesticide mixture, were aged for 0.25, 1, 4, 7, and 14 days. Recoveries of the pesticides in the sediments generally decreased with increased aging time, but the magnitude of the decline was pesticide and sediment dependent. The developed method was applied to field-collected sediments from the Central Valley of California.

  6. High-performance liquid chromatography analysis methods developed for quantifying enzymatic esterification of flavonoids in ionic liquids.

    Science.gov (United States)

    Lue, Bena-Marie; Guo, Zheng; Xu, Xuebing

    2008-07-11

    Methods using reversed-phase high-performance liquid chromatography (RP-HPLC) with ELSD were investigated to quantify enzymatic reactions of flavonoids with fatty acids in the presence of diverse room temperature ionic liquids (RTILs). A buffered salt (preferably triethylamine-acetate) was found essential for separation of flavonoids from strongly polar RTILs, whereby RTILs were generally visible as two major peaks identified based on an ion-pairing/exchanging hypothesis. C8 and C12 stationary phases were optimal while mobile phase pH (3-7) had only a minor influence on separation. The method developed was successfully applied for primary screening of RTILs (>20), with in depth evaluation of substrates in 10 RTILs, for their evaluation as reaction media.

  7. Development of the H-point standard additions method for coupled liquid-chromatography and UV-visible spectrophotometry

    Energy Technology Data Exchange (ETDEWEB)

    Campins-Falco, Pilar; Bosch-Reig, Francisco; Herraez-Hernandez, Rosa; Sevillano-Cabeza, Adela (Universidad de Valencia (Spain). Facultad de Quimica, Departamento de Quimica Analitica)

    1992-02-10

    This work establishes the fundamentals of the H-point standard additions method for liquid chromatography for the simultaneous analysis of binary mixtures with overlapped chromatographic peaks. The method was compared with the deconvolution method of peak suppression and the second derivative of elution profiles. Different mixtures of diuretics were satisfactorily resolved. (author). 21 refs.; 9 figs.; 2 tabs.

  8. Determination of haloacetic acids in water by ion chromatography--method development.

    Science.gov (United States)

    Lopez-Avila, V; Liu, Y; Charan, C

    1999-01-01

    The microextraction/ion chromatographic (IC) method developed in this study involves extraction of 9 haloacetic acids (HAAs) from aqueous samples (acidified with sulfuric acid to a pH of copper sulfate pentahydrate and sodium sulfate) with methyl tert-butyl ether (MTBE), back extraction into reagent water, and analysis by IC with conductivity detection. The separation column consists of an Ion Pac AG-11 (2 mm id x 50 mm length) guard column and an Ion Pac AS-11 (2 mm id x 250 mm length) analytical column, and the concentration column is a 4 mm id x 35 mm length Dionex TAC-LP column. Use of the 2 mm id Dionex AS-11 column improved detection limits especially for trichloracetic acid (TCAA), bromodichloroacetic acid (BDCAA), dibromochloroacetic acid (DBCAA), and tribromoacetic acid (TBAA). The peak interfering with BCAA elutes at the same retention time as nitrate; however, we have not confirmed the presence of nitrate. Stability studies indicate that HAAs are stable in water for at least 8 days when preserved with ammonium chloride at 100 mg/L and stored at 4 degrees C in the dark. At day 30, recoveries were still high (e.g., 92.1-106%) for dichloroacetic acid (DCAA), BCAA, dibromoacetic acid (DBAA), trichloroacetic acid (TCAA), BDCAA, and DBCAA. However, recoveries of monochloroacetic acid (MCAA), monobromoacetic acid (MBAA), and TBAA were only 54.6, 56.8, and 66.8%, respectively. Stability studies of HAAs in H2SO4-saturated MTBE indicate that all compounds except TBAA are stable for 48 h when stored at 4 degrees C in the dark. TBAA recoveries dropped to 47.1% after 6 h of storage and no TBAA was detected after 48 h of storage. The method described here is only preliminary and was tested in only one laboratory. Additional research is needed to improve method performance.

  9. Development of a high-performance liquid chromatography method for the determination of florfenicol in animal feedstuffs.

    Science.gov (United States)

    Yang, JinJing; Sun, GuiZhi; Qian, MingRong; Huang, LingLi; Ke, XianBing; Yang, Bo

    2017-11-15

    An effective thin layer chromatography (TLC) purification procedure coupled to high-performance liquid chromatography (HPLC) method was developed for the determination of florfenicol (FF) in pig, chicken and fish feedstuffs. The feedstuff samples were extracted with ethyl acetate, defatted with n-hexane saturated with acetonitrile, and further purified by TLC. The chromatographic separation was performed on a Waters Symmetry C 18 column using an isocratic procedure with acetonitrile-water (35:65, v/v) at 0.6mL/min. The ultraviolet (UV) detector was set at a wavelength of 225nm. The FF concentrations in feedstuff samples were quantified using a standard curve. Good linear correlations (y=159075x-15054, r>0.9999) were achieved within the concentration range of 0.05-200μg/mL. The recoveries of FF spiked at levels of 1, 100 and 1000μg/g ranged from 80.6% to 105.3% with the intra-day and inter-day relative standard deviation (RSD) less than 9.3%. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.02 and 0.06mg/kg for pig feedstuffs, 0.02 and 0.07mg/kg for chicken feedstuffs, and 0.02 and 0.05mg/kg for fish feedstuffs, respectively. This reliable, simple and cost-effective method could be applied to the routine monitoring of FF in animal feedstuffs. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Development of a method to extract and purify target compounds from medicinal plants in a single step: online hyphenation of expanded bed adsorption chromatography and countercurrent chromatography.

    Science.gov (United States)

    Li, Yang; Wang, Nan; Zhang, Min; Ito, Yoichiro; Zhang, Hongyang; Wang, Yuerong; Guo, Xin; Hu, Ping

    2014-04-01

    Pure compounds extracted and purified from natural sources are crucial to lead discovery and drug screening. This study presents a novel two-dimensional hyphenation of expanded bed adsorption chromatography (EBAC) and high-speed countercurrent chromatography (HSCCC) for extraction and purification of target compounds from medicinal plants in a single step. The EBAC and HSCCC were hyphenated via a six-port injection valve as an interface. Fractionation of ingredients of Salvia miltiorrhiza and Rhizoma coptidis was performed on the hyphenated system to verify its efficacy. Two compounds were harvested from Salvia miltiorrhiza, one was 52.9 mg of salvianolic acid B with an over 95% purity and the other was 2.1 mg of rosmarinic acid with a 74% purity. Another two components were purified from Rhizoma coptidis, one was 4.6 mg of coptisine with a 98% purity and one was 4.1 mg of berberine with a 82% purity. The processing time was nearly 50% that of the multistep method. The results indicate that the present method is a rapid and green way to harvest targets from medicinal plants in a single step.

  11. Method development for Lawsone estimation in Trichup herbal hair powder by high-performance thin layer chromatography

    Directory of Open Access Journals (Sweden)

    Maunang M Patel

    2013-01-01

    Full Text Available A simple, specific, accurate, precise and robust high-performance thin-layer chromatographic method has been developed and validated for estimation of Lawsone in Trichup herbal hair powder (coded as a THHP, polyherbal formulation. The chromatographic development was carried out on aluminum plates pre-coated with silica gel 60F 254 and good resolution was achieved with Toluene: Ethyl acetate: Glacial acetic acid (8:1:1 v/v/v as mobile phase. Lawsone detection was carried out densitometrically at 277 nm and obtained retardation factor value was 0.46 ± 0.02. The method was validated with respect to specificity, linearity, accuracy, precision and robustness. The calibration curve was achieved to be linear over a range of 5-60 μg/ml and regression coefficient was obtained 0.998. Accuracy of chromatographic method was evaluated by standard addition method; recovery was obtained 99.25 ± 0.61% . The peak purity of Lawsone was achieved 0.999 r. Relative standard deviation for intraday and inter-day precision was 0.37-0.56% and 0.42-0.55%, respectively. The limit of detection and limit of quantification of the Lawsone were found to be 1.08 μg/m land 3.28 μg/ml, respectively. This result shows that the method was well validated. In the present study, the Lawsone content was found 0.322 ± 0.014% in THHP. This study reveals that the proposed high performance thin layer chromatography method is accurate, fast and cost- effective for routine estimation of Lawsone in polyherbal formulation.

  12. Development of Extraction Methods for the Analysis of Perfluorinated Compounds in Leather with High Performance Liquid Chromatography Tandem Mass Spectrometry

    Science.gov (United States)

    Zhang, Yan; Wang, Youchao; Tang, Chuanjiang; Nie, Jingmei; Xu, Chengtao

    2018-01-01

    Perfluorinated compounds (PFCs), used to provide water, oil, grease, heat and stain repellency to a range of textile and other products, have been found to be persistent in the environment and are associated with adverse effects on humans and wildlife. This study presents the development and validation of an analytical method to determine the simultaneous presence of eleven PFCs in leather using solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The perfluorinated compounds were primarily extracted from the samples by a liquid extraction procedure by ultrasonic, in which the parameters were optimized. Then the solid-phase extraction (SPE) is the most important advantages of the developed methodology. The sample volume and elution conditions were optimized by means of an experimental design. The proposed method was applied to determine the PFCs in leather, where the detection limits of the eleven compounds were 0.09-0.96 ng/L, and the recoveries of all compounds spiked at 5 ng/L concentration level were in the range of 65-96%, with a better RSD lower than 19% (n = 7).

  13. Development of an analytical method to quantify total isoflavones in phytotherapic capsules using high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Liliane C. C. Auwerter

    2012-12-01

    Full Text Available Isoflavones can be found in grains and leaves of soybean. Currently, these are sold in pharmacies as phytotherapic capsules. Isoflavones have been recommended by doctors, especially for women, due to their ability to relieve menopause symptoms, among other benefits. However, no method exists for the official control of isoflavone content in capsules sold in the Brazilian market. This study aims to develop an appropriate analytical method to determine the total isoflavone content (daidzin, glycitin, and genistin, and their respective aglycone forms in phytotherapic capsules purchased in pharmacies in Curitiba, Parana State, Brazil, using the technique of high-performance liquid chromatography with UV detection (UV-HPLC. The HPLC system consisted of a quaternary pump, an autosampler, and Waters reversed-phase C18 column (5 μm × 300 mm. Analyses were carried out at 40 °C, using a flow rate of 1.0 mL/min (acetonitrile and acetic acid 0.1%, and detection was performed at 254 nm. The method was validated as required by ANVISA and showed to be reliable for the following parameters: linearity (r² >0.99, selectivity (correlation between 0.99 and 1.00, precision (relative standard derivation <1.59%, accuracy (from 80% to 111.63% intraday and from 80% to 117.88% interday recovery, and robustness.

  14. Development of an analytical method to quantify total isoflavones in phytotherapic capsules using high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Liliane C. C. Auwerter

    2012-10-01

    Full Text Available Isoflavones can be found in grains and leaves of soybean. Currently, these are sold in pharmacies as phytotherapic capsules. Isoflavones have been recommended by doctors, especially for women, due to their ability to relieve menopause symptoms, among other benefits. However, no method exists for the official control of isoflavone content in capsules sold in the Brazilian market. This study aims to develop an appropriate analytical method to determine the total isoflavone content (daidzin, glycitin, and genistin, and their respective aglycone forms in phytotherapic capsules purchased in pharmacies in Curitiba, Parana State, Brazil, using the technique of high-performance liquid chromatography with UV detection (UV-HPLC. The HPLC system consisted of a quaternary pump, an autosampler, and Waters reversed-phase C18 column (5 μm × 300 mm. Analyses were carried out at 40 °C, using a flow rate of 1.0 mL/min (acetonitrile and acetic acid 0.1%, and detection was performed at 254 nm. The method was validated as required by ANVISA and showed to be reliable for the following parameters: linearity (r² >0.99, selectivity (correlation between 0.99 and 1.00, precision (relative standard derivation <1.59%, accuracy (from 80% to 111.63% intraday and from 80% to 117.88% interday recovery, and robustness.

  15. Method Development for the Determination of Fluorotelomer Alcohols in Soils by Gas Chromatography Mass Spectrometry

    Science.gov (United States)

    Fluorotelomer alcohols (FTOHs) have been widely studied as precursors to perfluorocarboxylates, e.g. 8:2 FTOH degrades to perfluorooctanoic acid (PFOA). This presentation describes an analytical method for the extraction and analysis of 6:2, 8:2, and 10:2 FTOHs. Gas chromatograph...

  16. Development of a high performance liquid chromatography method and a liquid chromatography-tandem mass spectrometry method with pressurized liquid extraction for simultaneous quantification and confirmation of cyromazine, melamine and its metabolites in foods of animal origin

    International Nuclear Information System (INIS)

    Yu Huan; Tao Yanfei; Chen Dongmei; Wang Yulian; Liu Zhaoying; Pan Yuanhu; Huang Lingli; Peng Dapeng; Dai Menghong; Liu Zhenli; Yuan Zonghui

    2010-01-01

    Simple and sensitive methods have been developed for simultaneous detection of cyromazine, melamine and their metabolites (ammeline, ammelide and cyanuric acid) in samples of animal origins. These include a high performance liquid chromatography (HPLC) method and a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method and are useful in regular monitoring and in toxicity studies of these molecules. Representative samples used in this study include muscles and livers of swine, bovine, sheep and chicken, kidneys of swine, bovine and sheep, and milk powder. A new sample preparation procedure with pressurized liquid extraction (PLE) at 1400 psi and 70 deg. C was investigated. Quantification of these five compounds by HPLC was achieved using an APS-2 column with UV detection at 230 nm. Limit of detection (LOD) was at 10 μg kg -1 , and limit of quantification (LOQ) was at 40 μg kg -1 . Recoveries of the five analytes in spiked samples ranged from 72.2% to 115.4% with RSD less than 12%. Confirmatory analysis of the analytes was performed using LC-MS/MS in selected reaction monitoring (SRM) mode. The LOD and LOQ were 5 μg kg -1 and 15 μg kg -1 , respectively. This is the first simultaneous analysis of cyromazine, melamine, ammeline, ammelide and cyanuric acid residues in complex tissue samples using PLE and HPLC. It is expected that these methods will find many practical applications in evaluating the safety of cyromazine, melamine and their metabolites.

  17. Chiral liquid chromatography-mass spectrometry (LC-MS/MS) method development for the detection of salbutamol in urine samples.

    Science.gov (United States)

    Chan, Sue Hay; Lee, Warren; Asmawi, Mohd Zaini; Tan, Soo Choon

    2016-07-01

    A sequential solid-phase extraction (SPE) method was developed and validated using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) for the detection and quantification of salbutamol enantiomers in porcine urine. Porcine urine samples were hydrolysed with β-glucuronidase/arylsulfatase from Helix pomatia and then subjected to a double solid-phase extraction (SPE) first using the Abs-Elut Nexus SPE and then followed by the Bond Elut Phenylboronic Acid (PBA) SPE. The salbutamol enantiomers were separated using the Astec CHIROBIOTIC™ T HPLC column (3.0mm×100mm; 5μm) maintained at 15°C with a 15min isocratic run at a flow rate of 0.4mL/min. The mobile phase constituted of 5mM ammonium formate in methanol. Salbutamol and salbutamol-tert-butyl-d9 (internal standard, IS) was monitored and quantified with the multiple reaction monitoring (MRM) mode. The method showed good linearity for the range of 0.1-10ng/mL with limit of quantification at 0.3ng/mL. Analysis of the QC samples showed intra- and inter-assay precisions to be less than 5.04%, and recovery ranging from 83.82 to 102.33%. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Development of liquid chromatography-tandem mass spectrometry methods for the quantitation of Anisakis simplex proteins in fish.

    Science.gov (United States)

    Fæste, Christiane Kruse; Moen, Anders; Schniedewind, Björn; Haug Anonsen, Jan; Klawitter, Jelena; Christians, Uwe

    2016-02-05

    The parasite Anisakis simplex is present in many marine fish species that are directly used as food or in processed products. The anisakid larvae infect mostly the gut and inner organs of fish but have also been shown to penetrate into the fillet. Thus, human health can be at risk, either by contracting anisakiasis through the consumption of raw or under-cooked fish, or by sensitisation to anisakid proteins in processed food. A number of different methods for the detection of A. simplex in fish and products thereof have been developed, including visual techniques and PCR for larvae tracing, and immunological assays for the determination of proteins. The recent identification of a number of anisakid proteins by mass spectrometry-based proteomics has laid the groundwork for the development of two quantitative liquid chromatography-tandem mass spectrometry methods for the detection of A. simplex in fish that are described in the present study. Both, the label-free semi-quantitative nLC-nESI-Orbitrap-MS/MS (MS1) and the heavy peptide-applying absolute-quantitative (AQUA) LC-TripleQ-MS/MS (MS2) use unique reporter peptides derived from anisakid hemoglobin and SXP/RAL-2 protein as analytes. Standard curves in buffer and in salmon matrix showed limits of detection at 1μg/mL and 10μg/mL for MS1 and 0.1μg/mL and 2μg/mL for MS2. Preliminary method validation included the assessment of sensitivity, repeatability, reproducibility, and applicability to incurred and naturally-contaminated samples for both assays. By further optimization and full validation in accordance with current recommendations the LC-MS/MS methods could be standardized and used generally as confirmative techniques for the detection of A. simplex protein in fish. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Development of a Microemulsion High Performance Liquid Chromatography (MELC Method for Determination of Salbutamol in Metered-Dose Inhalers (MDIS

    Directory of Open Access Journals (Sweden)

    J Hanaee

    2013-02-01

    Full Text Available Introduction: A sensitive and rapid oil-in-water (O/W microemulsion high performance liquid chromatography (MELC method has been developed. The water-in-oil (w/o microemulsion was used as a mobile phase in the determination of salbutamol in aqueous solutions. In addition, the influence of operating parameters on the separation performance was examined. Methods: The samples were injected into C18, (250mm×4.6mm analytical columns maintained at 25oC with a flow rate 1 ml/min. The mobile phase was 95.5% v/v aqueous orthophosphate buffer 20 mM (adjusted to pH 3 with orthophosphoric acid, 0.5% ethyl acetate, 1.5% Brij35, and 2.5% 1-butanol, all w/w. The salbutamol and internal standard peaks were detected by fluorescence detection at the excitation and emission wavelengths of 267 and 313 nm respectively. Results: The method had an accuracy of > 97.78% and the calibration curve was linear (r2 = 0.99 over salbutamol concentrations ranging from 25 to 500 ng/mL. The intra-day and inter-day precisions (CV % were <1.6 and <1.8, respectively. The limit of detection (LOD and limit of quantitation (LOQ were 9.61ng/ml and 29.13ng/ml, respectively. Conclusion: The method reported is simple, precise and accurate, and has the capacity to be used for determination of salbutamol in the pharmaceutical preparation.

  20. High-performance liquid chromatography analysis methods developed for quantifying enzymatic esterification of flavonoids in ionic liquids

    DEFF Research Database (Denmark)

    Lue, Bena-Marie; Guo, Zheng; Xu, X.B.

    2008-01-01

    Methods using reversed-phase high-performance liquid chromatography (RP-HPLC) with ELSD were investigated to quantify enzymatic reactions of flavonoids with fatty acids in the presence of diverse room temperature ionic liquids (RTILs). A buffered salt (preferably triethylamine-acetate) was found...... essential for separation of flavonoids from strongly polar RTILs, whereby RTILs were generally visible as two major peaks identified based on an ion-pairing/exchanging hypothesis. C8 and C12 stationary phases were optimal while mobile phase pH (3-7) had only a minor influence on separation. The method...

  1. Identification of Hepatoprotective Constituents in Limonium tetragonum and Development of Simultaneous Analysis Method using High-performance Liquid Chromatography

    Science.gov (United States)

    Lee, Jae Sun; Kim, Yun Na; Kim, Na-Hyun; Heo, Jeong-Doo; Yang, Min Hye; Rho, Jung-Rae; Jeong, Eun Ju

    2017-01-01

    Background: Limonium tetragonum, a naturally salt-tolerant halophyte, has been studied recently and is of much interest to researchers due to its potent antioxidant and hepatoprotective activities. Objective: In the present study, we attempted to elucidate bioactive compounds from ethyl acetate (EtOAc) soluble fraction of L. tetragonum extract. Furthermore, the simultaneous analysis method of bioactive EtOAc fraction of L. tetragonum has been developed using high-performance liquid chromatography (HPLC). Materials and Methods: Thirteen compounds have been successfully isolated from EtOAc fraction of L. tetragonum, and the structures of 1–13 were elucidated by extensive one-dimensional and two-dimensional spectroscopic methods including 1H-NMR, 13C-NMR, 1H-1H COSY, heteronuclear single quantum coherence, heteronuclear multiple bond correlation, and nuclear Overhauser effect spectroscopy. Hepatoprotection of the isolated compounds against liver fibrosis was evaluated by measuring inhibition on hepatic stellate cells (HSCs) undergoing proliferation. Results: Compounds 1–13 were identified as gallincin (1), apigenin-3-O-β-D-galactopyranoside (2), quercetin (3), quercetin-3-O-β-D-galactopyranoside (4), (−)-epigallocatechin (5), (−)-epigallocatechin-3-gallate (6), (−)-epigallocatechin-3-(3″-O-methyl) gallate (7), myricetin-3-O-β-D-galactopyranoside (8), myricetin-3-O-(6″-O-galloyl)-β-D-galactopyranoside (9), myricetin-3-O-α-L-rhamnopyranoside (10), myricetin-3-O-(2″-O-galloyl)-α-L-rhamnopyranoside (11), myricetin-3-O-(3″-O-galloyl)-α-L-rhamnopyranoside (12), and myricetin-3-O-α-L-arabinopyranoside (13), respectively. All compounds except for 4, 8, and 10 are reported for the first time from this plant. Conclusion: Myricetin glycosides which possess galloyl substituent (9, 11, and 12) showed most potent inhibitory effects on the proliferation of HSCs. SUMMARY In the present study, we have successfully isolated 13 compounds from bioactive fraction

  2. Development of an analytical method for polycyclic aromatic hydrocarbons in coffee beverages and dark beer using novel high-sensitivity technique of supercritical fluid chromatography/mass spectrometry.

    Science.gov (United States)

    Yoshioka, Toshiaki; Nagatomi, Yasushi; Harayama, Koichi; Bamba, Takeshi

    2018-07-01

    Polycyclic aromatic hydrocarbons (PAHs) are carcinogenic substances that are mainly generated during heating in food; therefore, the European Union (EU) has regulated the amount of benzo[a]pyrene and PAH4 in various types of food. In addition, the Scientific Committee on Food of the EU and the Joint Food and Agriculture Organization/World Health Organization Expert Committee on Food Additives have recommended that 16 PAHs should be monitored. Since coffee beverages and dark beer are roasted during manufacture, monitoring these 16 PAHs is of great importance. On the other hand, supercritical fluid chromatography (SFC) is a separation method that has garnered attention in recent years as a complement for liquid and gas chromatography. Therefore, we developed a rapid high-sensitivity analytical method for the above-mentioned 16 PAHs in coffee beverages and dark beer involving supercritical fluid chromatography/atmospheric pressure chemical ionization-mass spectrometry (SFC/APCI-MS) and simple sample preparation. In this study, we developed a novel analytical technique that increased the sensitivity of MS detection by varying the back-pressure in SFC depending on the elution of PAHs. In addition, analysis of commercially available coffee and dark beer samples in Japan showed that the risk of containing the 16 PAHs may be low. Copyright © 2018 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  3. Development of a method based on on-line reversed phase liquid chromatography and gas chromatography coupled by means of an adsorption-desorption interface for the analysis of selected chiral volatile compounds in methyl jasmonate treated strawberries.

    Science.gov (United States)

    de la Peña Moreno, Fernando; Blanch, Gracia Patricia; Flores, Gema; Ruiz Del Castillo, Maria Luisa

    2010-02-12

    A method based on the use of the through oven transfer adsorption-desorption (TOTAD) interface in on-line coupling between reversed phase liquid chromatography and gas chromatography (RPLC-GC) for the determination of chiral volatile compounds was developed. In particular, the method was applied to the study of the influence of methyl jasmonate (MJ) treatment on the production and enantiomeric composition of selected aroma compounds in strawberry. The compounds studied were ethyl 2-methylbutanoate, linalool and 4-hydroxy-2,5-dimethyl-3(2H)-furanone (i.e. furaneol), which were examined on days 3, 6 and 9 after treatment. The method developed resulted in relative standard deviations (RSDs) of 21.6%, 8.1% and 9.8% and limits of detection (LD) of 0.04, 0.07 and 0.02mg/l for ethyl 2-methylbutanoate, linalool and furaneol, respectively. The application of the RPLC-TOTAD-GC method allowed higher levels of ethyl 2-methylbutanoate, linalool and furaneol to be detected, particularly after 9 days of treatment. Besides, MJ demonstrated to affect the enantiomeric distribution of ethyl 2-methylbutanoate. On the contrary, the enantiomeric composition of linalool and furaneol kept constant in both control and MJ-treated strawberries throughout the study. These results are discussed. Copyright 2009 Elsevier B.V. All rights reserved.

  4. Development of an analytical method coupling cell membrane chromatography with gas chromatography-mass spectrometry via microextraction by packed sorbent and its application in the screening of volatile active compounds in natural products.

    Science.gov (United States)

    Li, Miao; Wang, Sicen; He, Langchong

    2015-01-01

    Natural products (NPs) are important sources of lead compounds in modern drug discovery. To facilitate the screening of volatile active compounds in NPs, we have developed a new biochromatography method that uses rat vascular smooth muscle cells (VSMC), which are rich in L-type calcium channels (LCC), to prepare the stationary phase. This integrated method, which couples cell membrane chromatography (CMC) with gas chromatography-mass spectrometry (GC-MS) via microextraction by packed sorbent (MEPS) technology, has been termed VSMC/CMC-MEPS-GC-MS. Methodological validation confirmed its specificity, reliability and convenience. Screening results for Radix Angelicae Dahuricae and Fructus Cnidii obtained using VSMC/CMC-MEPS-GC-MS were consistent with those obtained using VSMC/CMC-offline-GC-MS. MEPS connection plays as simplified solid-phase extraction and replaces the uncontrollable evaporation operation in reported offline connections, so our new method is supposed to be more efficient and reliable than the offline ones, especially for compounds that are volatile, thermally unstable or difficult to purify. In application, senkyunolide A and ligustilide were preliminary identified as the volatile active components in Rhizoma Chuanxiong. We have thus confirmed the suitability of VSMC/CMC-MEPS-GC-MS for volatile active compounds screening in NP. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Analytical Method Development and Validation for the Simultaneous Estimation of Abacavir and Lamivudine by Reversed-phase High-performance Liquid Chromatography in Bulk and Tablet Dosage Forms.

    Science.gov (United States)

    Raees Ahmad, Sufiyan Ahmad; Patil, Lalit; Mohammed Usman, Mohammed Rageeb; Imran, Mohammad; Akhtar, Rashid

    2018-01-01

    A simple rapid, accurate, precise, and reproducible validated reverse phase high performance liquid chromatography (HPLC) method was developed for the determination of Abacavir (ABAC) and Lamivudine (LAMI) in bulk and tablet dosage forms. The quantification was carried out using Symmetry Premsil C18 (250 mm × 4.6 mm, 5 μm) column run in isocratic way using mobile phase comprising methanol: water (0.05% orthophosphoric acid with pH 3) 83:17 v/v and a detection wavelength of 245 nm and injection volume of 20 μl, with a flow rate of 1 ml/min. In the developed method, the retention times of ABAC and LAMI were found to be 3.5 min and 7.4 min, respectively. The method was validated in terms of linearity, precision, accuracy, limits of detection, limits of quantitation, and robustness in accordance with the International Conference on Harmonization guidelines. The assay of the proposed method was found to be 99% - 101%. The recovery studies were also carried out and mean % recovery was found to be 99% - 101%. The % relative standard deviation from reproducibility was found to be performance liquid chromatography, UV: Ultraviolet, ICH: International Conference on Harmonization, ABAC: Abacavir, LAMI: Lamivudine, HIV: Human immunodeficiency virus, AIDS: Acquired immunodeficiency syndrome, NRTI: Nucleoside reverse transcriptase inhibitors, ARV: Antiretroviral, RSD: Relative standard deviation, RT: Retention time, SD: Standard deviation.

  6. Rapid Development and Validation of Improved Reversed-Phase High-performance Liquid Chromatography Method for the Quantification of Mangiferin, a Polyphenol Xanthone Glycoside in Mangifera indica.

    Science.gov (United States)

    Naveen, P; Lingaraju, H B; Prasad, K Shyam

    2017-01-01

    Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica , is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica . RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography-mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica . The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica . The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed

  7. Liquid chromatography detection unit, system, and method

    Science.gov (United States)

    Derenzo, Stephen E.; Moses, William W.

    2015-10-27

    An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method of liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.

  8. Comparative urine analysis by liquid chromatography-mass spectrometry and multivariate statistics : Method development, evaluation, and application to proteinuria

    NARCIS (Netherlands)

    Kemperman, Ramses F. J.; Horvatovich, Peter L.; Hoekman, Berend; Reijmers, Theo H.; Muskiet, Frits A. J.; Bischoff, Rainer

    2007-01-01

    We describe a platform for the comparative profiling of urine using reversed-phase liquid chromatography-mass spectrometry (LC-MS) and multivariate statistical data analysis. Urinary compounds were separated by gradient elution and subsequently detected by electrospray Ion-Trap MS. The lower limit

  9. Development and evaluation of a liquid chromatography tandem mass spectrometry method for simultaneous determination of salivary melatonin, cortisol and testosterone

    DEFF Research Database (Denmark)

    Jensen, Marie Aarrebo; Hansen, Åse Marie; Abrahamsson, Peter

    2011-01-01

    saliva. We used liquid-liquid extraction (LLE) followed by liquid chromatography coupled to electrospray tandem mass spectrometry (LC-ESI-MS/MS) recorded in positive ion mode. Saliva samples were collected by spitting directly into tubes and 250 µL were used for analysis. The limits of detection were 4...

  10. Development, validation, and application of a method for selected avermectin determination in rural waters using high performance liquid chromatography and fluorescence detection.

    Science.gov (United States)

    Lemos, Maria Augusta Travassos; Matos, Camila Alves; de Resende, Michele Fabri; Prado, Rachel Bardy; Donagemma, Raquel Andrade; Netto, Annibal Duarte Pereira

    2016-11-01

    Avermectins (AVM) are macrocyclic lactones used in livestock and agriculture. A quantitative method of high performance liquid chromatography with fluorescence detection for the determination of eprinomectin, abamectin, doramectin and ivermectin in rural water samples was developed and validated. The method was employed to study samples collected in the Pito Aceso River microbasin, located in the Bom Jardim municipality, Rio de Janeiro State, Brazil. Samples were extracted by solid phase extraction using a polymeric stationary phase, the eluted fraction was re-concentrated under a gentle N2 flow and derivatized to allow AVM determination using liquid chromatography with fluorescence detection. The excitation and emission wavelengths of the derivatives were 365 and 470nm, respectively, and a total chromatographic run of 12min was achieved. Very low limits of quantification (22-58ngL(-1)) were found after re-concentration using N2. Recovery values varied from 85.7% to 119.2% with standard deviations between 1.2% and 10.2%. The validated method was applied in the determination of AVM in 15 water samples collected in the Pito Aceso River microbasin, but most of them were free of AVM or showed only trace levels of these compounds, except for a sample that contained doramectin (9.11µgL(-1)). The method is suitable for routine analysis with satisfactory recovery, sensitivity, and selectivity. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Development of QuEChERS-based extraction and liquid chromatography-tandem mass spectrometry method for quantifying flumethasone residues in beef muscle.

    Science.gov (United States)

    Park, Ki Hun; Choi, Jeong-Heui; Abd El-Aty, A M; Cho, Soon-Kil; Park, Jong-Hyouk; Kwon, Ki Sung; Park, Hee Ra; Kim, Hyung Soo; Shin, Ho-Chul; Kim, Mi Ra; Shim, Jae-Han

    2012-12-01

    A rapid, specific, and sensitive method based on liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) in the positive ion mode using multiple reaction monitoring (MRM) was developed and validated to quantify flumethasone residues in beef muscle. Methods were compared between the original as well as the EN quick, easy, cheap, effective, rugged, and safe (QuEChERS)-based extraction. Good linearity was achieved at concentration levels of 5-30 μg/kg. Estimated recovery rates at spiking levels of 5 and 10 μg/kg ranged from 72.1 to 84.6%, with relative standard deviations (RSDs)noise ratios (S/Ns) of 3 and 10, respectively. The method was successfully applied to analyze real samples obtained from large markets throughout the Korean Peninsula. The method proved to be sensitive and reliable and, thus, rendered an appropriate means for residue analysis studies. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Methods of uranium isotpic separation by chemical exchange chromatography

    International Nuclear Information System (INIS)

    Pena V, L.A.; Valle M, L.

    1985-01-01

    Chemical exchange chromatography as applied to isotope separation has undergone a constant development during the last few years. The results so far indicate that this method could eventually become commercially useful. This work presents a critical review of the experimental methods presently under study by principal research groups, and which have not get been compared. (Author)

  13. Development and validation of a method for detection and quantification of ochratoxin A in green coffee using liquid chromatography coupled to mass spectrometry

    Directory of Open Access Journals (Sweden)

    Raquel Duarte da Costa Cunha Bandeira

    2012-12-01

    Full Text Available A method using Liquid Chromatography Tanden Mass Spectrometry (LC-MS/MS with matrix-matched calibration curve was developed and validated for determining ochratoxin A (OTA in green coffee. Linearity was found between 3.0 and 23.0 ng.g-1. Mean recoveries ranged between 90.45% and 108.81%; the relative standard deviation under repeatability and intermediate precision conditions ranged from 5.39% to 9.94% and from 2.20% to 14.34%, respectively. The limits of detection and quantification were 1.2 ng.g-1 and 3.0 ng.g-¹, respectively. The method developed was suitable and contributed to the field of mycotoxin analysis, and it will be used for future production of the Certified Reference Material (CRM for OTA in coffee.

  14. Development and validation of a rapid resolution liquid chromatography method for the screening of dietary plant isoprenoids: carotenoids, tocopherols and chlorophylls.

    Science.gov (United States)

    Stinco, Carla M; Benítez-González, Ana M; Hernanz, Dolores; Vicario, Isabel M; Meléndez-Martínez, Antonio J

    2014-11-28

    A rapid resolution liquid chromatography (RRLC) method was developed and validated for the simultaneous determination of nine carotenoids compounds (violaxanthin, lutein, zeaxanthin, β-cryptoxanthin, α-carotene, β-carotene, lycopene, phytoene, phytofluene), four tocopherols and four chlorophylls and derivates (chlorophylls and pheophytins). The methodology consisted in a micro-extraction procedure with or without saponification and subsequent analysis by RRLC. The limits of detection were saponification step was performed. The recovery of the method without the saponification step ranged from 92% to 107%, whilst that when saponification was carried out ranged from 60% for α-tocopherol to 82% for β-carotene. Finally, the applicability of the method was demonstrated by the identification and quantification of isoprenoids in different samples. The methodology is appropriate for the high-throughput screening of dietary isoprenoids in fruits and vegetables. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Development of a multiresidue method for the determination of endocrine disrupters in fish fillet using gas chromatography-triple quadrupole tandem mass spectrometry.

    Science.gov (United States)

    Munaretto, Juliana S; Ferronato, Giovana; Ribeiro, Lucila C; Martins, Manoel L; Adaime, Martha B; Zanella, Renato

    2013-11-15

    Endocrine Disrupter Compounds (EDCs) are responsible for alterations in the endocrine system functions. Aquatic organisms are able to accumulate EDCs residues, being the major source of contamination for top predators and human consumers. This study aimed to develop and validate a method for the determination of 40 EDCs in fish fillet using modified QuEChERS and Gas Chromatography coupled with Mass Spectrometry in tandem (GC-MS/MS). A factorial design was used to optimize the extraction procedure. Method validation presented recoveries from 70.1% to 120.0% with RSDfish fillet from different species and residues of bisphenol A, chlorpyrifos and bifenthrin were detected. The proposed method proved to be effective for the determination of EDCs in fish fillet at very low concentration levels. © 2013 Elsevier B.V. All rights reserved.

  16. Method development for the analysis of 1,4-dioxane in drinking water using solid-phase extraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Grimmett, Paul E; Munch, Jean W

    2009-01-01

    1,4-Dioxane has been identified as a probable human carcinogen and an emerging contaminant in drinking water. The United States Environmental Protection Agency's (U.S. EPA) National Exposure Research Laboratory (NERL) has developed a method for the analysis of 1,4-dioxane in drinking water at ng/L concentrations. The method consists of an activated carbon solid-phase extraction of 500-mL or 100-mL water samples using dichloromethane as the elution solvent. The extracts are analyzed by gas chromatography-mass spectrometry (GC-MS) in selected ion monitoring (SIM) mode. In the NERL laboratory, recovery of 1,4-dioxane ranged from 94-110% in fortified laboratory reagent water and recoveries of 96-102% were demonstrated for fortified drinking water samples. The relative standard deviations for replicate analyses were less than 6% at concentrations exceeding the minimum reporting level.

  17. Development and validation of High-performance Thin-layer Chromatography Method for Simultaneous Determination of Polyphenolic Compounds in Medicinal Plants.

    Science.gov (United States)

    Jayachandran Nair, C V; Ahamad, Sayeed; Khan, Washim; Anjum, Varisha; Mathur, Rajani

    2017-12-01

    Quantitative standardization of plant-based products is challenging albeit essential to maintain their quality. This study aims to develop and validate high-performance thin-layer chromatography (HPTLC) method for the simultaneous determination of rutin (Ru), quercetin (Qu), and gallic acid (Ga) from Psidium guajava Linn. (PG) and Aegle marmelos (L.) Correa. (AM) and correlate with antioxidant activity. The stock solution (1 mg/mL) of standard Ru, Qu, and Ga in methanol: Water (1:1) was serially diluted and spotted (5 μL) on slica gel 60 F 254 thin-layer chromatography plates. Toluene: Ethyl acetate: Formic acid: Methanol (3:4:0.8:0.7, v/v/v) was selected as mobile phase for analysis at 254 nm. Hydroalcoholic (1:1) extracts of leaves of PG and AM were fractionated and similarly analyzed. Antioxidant activity was also determined using 2, 2-diphenyl-1-picrylhydrazyl assay. The developed method was robust and resolved Ru, Qu, and Ga at R f 0.08 ± 0.02, 0.76 ± 0.01, and 0.63 ± 0.02, respectively. The intra-day, interday precision, and interanalyst were limit of detection and limit of quantification for Ru, Qu, and Ga were 4.51, 4.2, 5.27, and 13.67, 12.73, 15.98 ng/spot, respectively. Antioxidant activity (Log 50% inhibition) of PG and AM was 4.947 ± 0.322 and 6.498 ± 0.295, respectively. The developed HPTLC method was rapid, accurate, precise, reproducible, and specific for the simultaneous estimation of Ru, Qu, and Ga. HPTLC method for simultaneous determination and quantification of Rutin, Quercetin and Gallic acid, is reported for quality control of herbal drugs. Abbreviations Used: A: Aqueous fraction; AM: Aegle marmelos L. Correa; B: Butanol fraction; C: Chloroform fraction; EA: Ethyl acetate fraction; Ga: Gallic acid; H: Hexane fraction; HA: Hydroalcoholic extract; HPTLC: High-performance thin-layer chromatography; PG: Psidium guajava ; Qu: Quercetin; Ru: Rutin.

  18. Development and validation of an ultra-performance liquid chromatography quadrupole time of flight mass spectrometry method for rapid quantification of free amino acids in human urine.

    Science.gov (United States)

    Joyce, Richard; Kuziene, Viktorija; Zou, Xin; Wang, Xueting; Pullen, Frank; Loo, Ruey Leng

    2016-01-01

    An ultra-performance liquid chromatography quadrupole time of flight mass spectrometry (UPLC-qTOF-MS) method using hydrophilic interaction liquid chromatography was developed and validated for simultaneous quantification of 18 free amino acids in urine with a total acquisition time including the column re-equilibration of less than 18 min per sample. This method involves simple sample preparation steps which consisted of 15 times dilution with acetonitrile to give a final composition of 25 % aqueous and 75 % acetonitrile without the need of any derivatization. The dynamic range for our calibration curve is approximately two orders of magnitude (120-fold from the lowest calibration curve point) with good linearity (r (2) ≥ 0.995 for all amino acids). Good separation of all amino acids as well as good intra- and inter-day accuracy (amino acids in the prepared urine samples was found to be stable for 72 h at 4 °C, after one freeze thaw cycle and for up to 4 weeks at -80 °C. We have applied this method to quantify the content of 18 free amino acids in 646 urine samples from a dietary intervention study. We were able to quantify all 18 free amino acids in these urine samples, if they were present at a level above the LOD. We found our method to be reproducible (accuracy and precision were typically <10 % for QCL, QCM and QCH) and the relatively high sample throughput nature of this method potentially makes it a suitable alternative for the analysis of urine samples in clinical setting.

  19. Development and validation of an ionic chromatography method for the determination of nitrate, nitrite and chloride in meat.

    Science.gov (United States)

    Lopez-Moreno, Cristina; Perez, Isabel Viera; Urbano, Ana M

    2016-03-01

    The purpose of this study is to develop the validation of a method for the analysis of certain preservatives in meat and to obtain a suitable Certified Reference Material (CRM) to achieve this task. The preservatives studied were NO3(-), NO2(-) and Cl(-) as they serve as important antimicrobial agents in meat to inhibit the growth of bacteria spoilage. The meat samples were prepared using a treatment that allowed the production of a known CRM concentration that is highly homogeneous and stable in time. The matrix effects were also studied to evaluate the influence on the analytical signal for the ions of interest, showing that the matrix influence does not affect the final result. An assessment of the signal variation in time was carried out for the ions. In this regard, although the chloride and nitrate signal remained stable for the duration of the study, the nitrite signal decreased appreciably with time. A mathematical treatment of the data gave a stable nitrite signal, obtaining a method suitable for the validation of these anions in meat. A statistical study was needed for the validation of the method, where the precision, accuracy, uncertainty and other mathematical parameters were evaluated obtaining satisfactory results. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Development of a method for the determination of 9 currently used cotton pesticides by gas chromatography with electron capture detection.

    Science.gov (United States)

    Zhang, Baohong; Pan, Xiaoping; Venne, Louise; Dunnum, Suzy; McMurry, Scott T; Cobb, George P; Anderson, Todd A

    2008-05-30

    A reliable, sensitive, and reproducible method was developed for quantitative determination of nine new generation pesticides currently used in cotton agriculture. Injector temperature significantly affected analyte response as indicated by electron capture detector (ECD) chromatograms. A majority of the analytes had an enhanced response at injector temperatures between 240 and 260 degrees C, especially analytes such as acephate that overall had a poor response on the ECD. The method detection limits (MDLs) were 0.13, 0.05, 0.29, 0.35, 0.08, 0.10, 0.32, 0.05, and 0.59 ng/mL for acephate, trifuralin, malathion, thiamethozam, pendimethalin, DEF6, acetamiprid, brifenthrin, and lambda-cyhalothrin. This study provides a precision (0.17-13.1%), accuracy (recoveries=88-107%) and good reproducible method for the analytes of interest. At relatively high concentrations, only lambda-cyhalothrin was unstable at room temperature (20-25 degrees C) and 4 degrees C over 10 days. At relatively low concentrations, acephate and acetamiprid were also unstable regardless of temperature. After 10 days storage at room temperature, 30-40% degradation of lambda-cyhalothrin was observed. It is recommended that acephate, acetamiprid, and lambda-cyhalothrin be stored at -20 degrees C or analyzed immediately after extraction.

  1. Development of a liquid chromatography tandem mass spectrometry method for iothalamate measurement to assess renal function for potential kidney donation.

    Science.gov (United States)

    Rhea, Jeanne M; Ritchie, James C; Molinaro, Ross J

    2013-05-01

    Chronic kidney disease often goes undetected due to the insensitivity of current methods to accurately assess glomerular filtration rate (GFR) in early stages of renal dysfunction. The clearance of exogenously introduced iothalamate, a commonly used radiopaque agent, is an alternative to inulin clearance for the assessment of renal function and its use in calculating GFR can serve as a screening tool for kidney transplant donors. A method was developed to measure iothalamate in plasma and urine samples by HPLC combined with electrospray positive ionization tandem mass spectrometry (MS/MS). Iothalamate is isolated from plasma by methanol extraction and urine using a quick-spin filtration approach, then monitored by multiple reaction monitoring using the hydrogen adduct mass transitions. Iohexol was used as an internal standard. Iothalamate was measured within an analytical run time of 5 min, with a lower limit of quantification of 18.75 ng/ml. The intraassay and interassay variations of the plasma and urine iothalamate assays were both calculated using the patient's urine flow rate and plasma and urine iothalamate values. Linear correlations tested by LC-MS/MS and an accepted capillary electrophoresis (CE) assay showed similar results (GFR, r=0.92, Sy/x=10.3). We developed and validated an LC-MS/MS method for quantitating iothalamate in plasma and urine to calculate GFR used for screening potential kidney donors in our hospital system. A less sensitive mass spectrometry system does not sacrifice analytical or clinical sensitivity for measuring GFR. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Analytical method development and validation of simultaneous estimation of rabeprazole, pantoprazole, and itopride by reverse-phase high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Senthamil Selvan Perumal

    2014-12-01

    Full Text Available A simple, selective, rapid, and precise reverse-phase high-performance liquid chromatography (RP-HPLC method for the simultaneous estimation of rabeprazole (RP, pantoprazole (PP, and itopride (IP has been developed. The compounds were well separated on a Phenomenex C18 (Luna column (250 mm × 4.6 mm, dp = 5 μm with C18 guard column (4 mm × 3 mm × 5 μm with a mobile phase consisting of buffer containing 10 mM potassium dihydrogen orthophosphate (adjusted to pH 6.8: acetonitrile (70:30 v/v at a flow rate of 1.0 mL/min and ultraviolet detection at 288 nm. The retention time of RP, PP, and IP were 5.35, 7.92, and 11.16 minutes, respectively. Validation of the proposed method was carried out according to International Conference on Harmonisation (ICH guidelines. Linearity range was obtained for RP, PP, and IP over the concentration range of 2.5–25, 1–30, and 3–35 μg/mL and the r2 values were 0.994, 0.978, and 0.991, respectively. The calculated limit of detection (LOD values were 1, 0.3, and 1 μg/mL and limit of quantitation (LOQ values were 2.5, 1, and 3 μg/mL for RP, PP, and IP correspondingly. Thus, the current study showed that the developed reverse-phase liquid chromatography method is sensitive and selective for the estimation of RP, PP, and IP in combined dosage form.

  3. Analytical method development and validation of simultaneous estimation of rabeprazole, pantoprazole, and itopride by reverse-phase high-performance liquid chromatography.

    Science.gov (United States)

    Perumal, Senthamil Selvan; Ekambaram, Sanmuga Priya; Raja, Samundeswari

    2014-12-01

    A simple, selective, rapid, and precise reverse-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of rabeprazole (RP), pantoprazole (PP), and itopride (IP) has been developed. The compounds were well separated on a Phenomenex C 18 (Luna) column (250 mm × 4.6 mm, dp = 5 μm) with C 18 guard column (4 mm × 3 mm × 5 μm) with a mobile phase consisting of buffer containing 10 mM potassium dihydrogen orthophosphate (adjusted to pH 6.8): acetonitrile (70:30 v/v) at a flow rate of 1.0 mL/min and ultraviolet detection at 288 nm. The retention time of RP, PP, and IP were 5.35, 7.92, and 11.16 minutes, respectively. Validation of the proposed method was carried out according to International Conference on Harmonisation (ICH) guidelines. Linearity range was obtained for RP, PP, and IP over the concentration range of 2.5-25, 1-30, and 3-35 μg/mL and the r 2 values were 0.994, 0.978, and 0.991, respectively. The calculated limit of detection (LOD) values were 1, 0.3, and 1 μg/mL and limit of quantitation (LOQ) values were 2.5, 1, and 3 μg/mL for RP, PP, and IP correspondingly. Thus, the current study showed that the developed reverse-phase liquid chromatography method is sensitive and selective for the estimation of RP, PP, and IP in combined dosage form. Copyright © 2014. Published by Elsevier B.V.

  4. Development of a Supercritical Fluid Chromatography-Tandem Mass Spectrometry Method for the Determination of Azacitidine in Rat Plasma and Its Application to a Bioavailability Study

    Directory of Open Access Journals (Sweden)

    Dongpo Li

    2013-12-01

    Full Text Available Azacitidine is widely used for the treatment of myelodysplastic syndromes (MDS and acute myelogenous leukaemia (AML. The analysis of azacitidine in biological samples is subject to interference by endogenous compounds. Previously reported high-performance liquid chromatography/tandem mass spectrometric (HPLC-MS/MS bioanalytical assays for azacitidine suffer from expensive sample preparation procedures or from long separation times to achieve the required selectivity. Herein, supercritical fluid chromatography with tandem mass spectrometry (SFC-MS/MS was explored as a more promising technique for the selective analysis of structure-like or chiral drugs in biological matrices. In this study, a simple, rapid and specific SFC/MS/MS analytical method was developed for the determination of azacitidine levels in rat plasma. Azacitidine was completely separated from the endogenous compounds on an ACQUITY UPLC™ BEH C18 column (100 mm × 3.0 mm, 1.7 μm; Waters Corp., Milford, MA, USA using isocratic elution with CO2/methanol as the mobile phase. The single-run analysis time was as short as 3.5 min. The sample preparation for protein removal was accomplished using a simple methanol precipitation method. The lower limit of quantification (LLOQ of azacitidine was 20 ng/mL. The intra-day and inter-day precisions were less than 15%, and the relative error (RE was within ±15% for the medium- and high-concentration quality control (QC samples and within ±20% for the low-concentration QC samples. Finally, the developed method was successfully applied to a pharmacokinetic study in rats following the intravenous administration of azacitidine.

  5. Development of Validated High-performance Thin-layer Chromatography Method for Simultaneous Determination of Quercetin and Kaempferol in Thespesia populnea.

    Science.gov (United States)

    Panchal, Hiteksha; Amin, Aeshna; Shah, Mamta

    2017-01-01

    Thespesia populnea L. (Family: Malvaceae) is a well-known medicinal plant distributed in tropical regions of the world and cultivated in South Gujarat and indicated to be useful in cutaneous affections, psoriasis, ringworm, and eczema. Bark and fruits are indicated in the diseases of skin, urethritis, and gonorrhea. The juice of fruits is employed in treating certain hepatic diseases. The plant is reported to contain flavonoids, quercetin, kaempferol, gossypetin, Kaempferol-3-monoglucoside, β-sitosterol, kaempferol-7-glucoside, and gossypol. T. populnea is a common component of many herbal and Ayurvedic formulation such as Kamilari and Liv-52. The present study aimed at developing validated and reliable high-performance thin layer chromatography (HPTLC) method for the analysis of quercetin and kaempferol simultaneously in T. populnea . The method employed thin-layer chromatography aluminum sheets precoated with silica gel as the stationary phase and toluene: ethyl acetate: formic acid (6:4:0.3 v/v/v) as the mobile phase, which gave compact bands of quercetin and kaempferol. Linear regression data for the calibration curves of standard quercetin and kaempferol showed a good linear relationship over a concentration range of 100-600 ng/spot and 500-3000 ng/spot with respect to the area and correlation coefficient (R2) was 0.9955 and 0.9967. The method was evaluated regarding accuracy, precision, selectivity, and robustness. Limits of detection and quantitation were recorded as 32.06 and 85.33 ng/spot and 74.055 and 243.72 ng/spot for quercetin and kaempferol, respectively. We concluded that this method employing HPTLC in the quantitative determination of quercetin and kaempferol is efficient, simple, accurate, and validated.

  6. Development and validation of a high-performance liquid chromatography method with post-column derivatization for the detection of aflatoxins in cereals and grains.

    Science.gov (United States)

    Asghar, Muhammad Asif; Iqbal, Javed; Ahmed, Aftab; Khan, Mobeen Ahmed; Shamsuddin, Zuzzer Ali; Jamil, Khalid

    2016-06-01

    A novel, reliable and rapid high-performance liquid chromatography (HPLC) method with post-column derivatization was developed and validated. The HPLC method was used for the simultaneous determination of aflatoxin B1 (AFB1), B2 (AFB2), G1 (AFG1) and G2 (AFG2) in various cereals and grains. Samples were extracted with 80:20 (v/v) methanol:water and purified using C18 (40-63 μm) solid-phase extraction cartridges. AFs were separated using a LiChroCART-RP-18 (5 μm, 250 × 4.0 mm(2)) column. The mobile phase consisted of methanol:acetonitrile:buffer (17.5:17.5:65 v/v) (pH 7.4) delivered at the flow rate of 1.0 mL min(-1) The fluorescence of each AF was detected at λex = 365 nm and λem = 435 nm. All four AFs were properly resolved within the total run time of 20 min. The established method was extensively validated as a final verification of the method development by the evaluation of selectivity (AFB1, AFB2, AFG1 and AFG2), linearity (R(2) ≥ 0.9994), precision (average SD ≤ 2.79), accuracy (relative mean error ≤ -5.51), robustness (p HPLC method could be effectively applied for the routine analysis of the AFs in different cereals and grains. © The Author(s) 2014.

  7. Development of a Multi-class Steroid Hormone Screening Method using Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS)

    Science.gov (United States)

    Boggs, Ashley S. P.; Bowden, John A.; Galligan, Thomas M.; Guillette, Louis J.; Kucklick, John R.

    2016-01-01

    Monitoring complex endocrine pathways is often limited by indirect measurement or measurement of a single hormone class per analysis. There is a burgeoning need to develop specific direct-detection methods capable of providing simultaneous measurement of biologically relevant concentrations of multiple classes of hormones (estrogens, androgens, progestogens, and corticosteroids). The objectives of this study were to develop a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for multi-class steroid hormone detection using biologically relevant concentrations, then test limits of detection (LOD) in a high-background matrix by spiking charcoal-stripped fetal bovine serum (FBS) extract. Accuracy was tested with National Institute of Standards and Technology Standard Reference Materials (SRMs) with certified concentrations of cortisol, testosterone, and progesterone. 11-Deoxycorticosterone, 11-deoxycortisol, 17-hydroxypregnenolone, 17-hydroxyprogesterone, adrenosterone, androstenedione, cortisol, corticosterone, dehydroepiandrosterone, dihydrotestosterone, estradiol, estriol, estrone, equilin, pregnenolone, progesterone, and testosterone were also measured using isotopic dilution. Dansyl chloride (DC) derivatization was investigated maintaining the same method to improve and expedite estrogen analysis. Biologically relevant LODs were determined for 15 hormones. DC derivatization improved estrogen response two- to eight-fold, and improved chromatographic separation. All measurements had an accuracy ≤ 14 % difference from certified values (not accounting for uncertainty) and relative standard deviation ≤ 14 %. This method chromatographically separated and quantified biologically relevant concentrations of four hormone classes using highly specific fragmentation patterns and measured certified values of hormones that were previously split into three separate chromatographic methods. PMID:27039201

  8. Hydrophilic interaction liquid chromatography in analysis of granisetron HCl and its related substances. Retention mechanisms and method development.

    Science.gov (United States)

    Maksić, Jelena; Tumpa, Anja; Stajić, Ana; Jovanović, Marko; Rakić, Tijana; Jančić-Stojanović, Biljana

    2016-05-10

    In this paper separation of granisetron and its two related substances in HILIC mode is presented. Separation was done on silica column derivatized with sulfoalkylbetaine groups (ZIC-HILIC). Firstly, retention mechanisms were assessed whereby retention factors of substances were followed in wide range of acetonitrile content (80-97%), at constant concentration of aqueous buffer (10mM) as well as at constant pH value of 3.0. Further, in order to developed optimal HILIC method, Design of Experiments (DoE) methodology was applied. For optimization full factorial design 3(2) was employed. Influence of acetonitrile content and ammonium acetate concentration were investigated while pH of the water phase was kept at 3.3. Adequacy of obtained mathematical models was confirmed by ANOVA. Optimization goals (α>1.15 and minimal run time) were accomplished with 94.7% of acetonitrile in mobile phase and 70 mM of ammonium acetate in water phase. Optimal point was in the middle of defined Design Space. In the next phase, robustness was experimetally tested by Rechtschaffen design. The investigated factors and their levels were: acetonitrile content (±1%), ammonium acetate molarity in water phase (±2 mM), pH value of water phase (±0.2) and column temperature (±4 °C). The validation scope included selectivity, linearity, accuracy and precision as well as determination of limit of detection (LOD) and limit of quantification (LOQ) for the related substances. Additionally, the validation acceptance criteria were met in all cases. Finally, the proposed method could be successfully utilized for estimation of granisetron HCl and its related substances in tablets and parenteral dosage forms, as well as for monitoring degradation under various stress conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Analytical method development for the determination of emerging contaminants in water using supercritical-fluid chromatography coupled with diode-array detection.

    Science.gov (United States)

    Del Carmen Salvatierra-Stamp, Vilma; Ceballos-Magaña, Silvia G; Gonzalez, Jorge; Ibarra-Galván, Valentin; Muñiz-Valencia, Roberto

    2015-05-01

    An analytical method using supercritical-fluid chromatography coupled with diode-array detection for the determination of seven emerging contaminants-two pharmaceuticals (carbamazepine and glyburide), three endocrine disruptors (17α-ethinyl estradiol, bisphenol A, and 17β-estradiol), one bactericide (triclosan), and one pesticide (diuron)-was developed and validated. These contaminants were chosen because of their frequency of use and their toxic effects on both humans and the environment. The optimized chromatographic separation on a Viridis BEH 2-EP column achieved baseline resolution for all compounds in less than 10 min. This separation was applied to environmental water samples after sample preparation. The optimized sample treatment involved a preconcentration step by means of solid-phase extraction using C18-OH cartridges. The proposed method was validated, finding recoveries higher than 94 % and limits of detection and limits of quantification in the range of 0.10-1.59 μg L(-1) and 0.31-4.83 μg L(-1), respectively. Method validation established the proposed method to be selective, linear, accurate, and precise. Finally, the method was successfully applied to environmental water samples.

  10. Method development and validation of liquid chromatography-tandem/mass spectrometry for aldosterone in human plasma: Application to drug interaction study of atorvastatin and olmesartan combination

    Directory of Open Access Journals (Sweden)

    Rakesh Das

    2014-01-01

    Full Text Available In the present investigation, a simple and sensitive liquid chromatography-tandem mass spectrometry (LC/MS/MS method was developed for the quantification of aldosterone (ALD a hormone responsible for blood pressure in human plasma. The developed method was validated and extended for application on human subjects to study drug interaction of atorvastatin (ATSV and olmesartan (OLM on levels of ALD. The ALD in plasma was extracted by liquid-liquid extraction with 5 mL dichloromethane/ethyl ether (60/40% v/v. The chromatographic separation of ALD was carried on Xterra, RP-Column C18 (150 mm× 4.6 mm × 3.5 μm at 30°C followed by four-step gradient program composed of methanol and water. Step 1 started with 35% methanol for first 1 min and changed linearly to 90% in next 1.5 min in Step 2. Step 3 lasted for next 2 min with 90% methanol. The method finally concluded with Step 4 to achieve initial concentration of methanol that is, 35% thus contributing the total method run time of 17.5 min. The flow rate was 0.25 mL/min throughout the process. The developed method was validated for specificity, accuracy, precision, stability, linearity, sensitivity, and recovery. The method was linear and found to be acceptable over the range of 50-800 ng/mL. The method was successfully applied for the drug interaction study of ATSV + OLM in combination against OLM treatment on blood pressure by quantifying changes in levels of ALD in hypertensive patients. The study revealed levels of ALD were significantly higher in ATSV + OLM treatment condition when compared to OLM as single treated condition. This reflects the reason of low effectiveness of ATSV + OLM in combination instead of synergistic activity.

  11. Development, optimization, validation and application of faster gas chromatography - flame ionization detector method for the analysis of total petroleum hydrocarbons in contaminated soils.

    Science.gov (United States)

    Zubair, Abdulrazaq; Pappoe, Michael; James, Lesley A; Hawboldt, Kelly

    2015-12-18

    This paper presents an important new approach to improving the timeliness of Total Petroleum Hydrocarbon (TPH) analysis in the soil by Gas Chromatography - Flame Ionization Detector (GC-FID) using the CCME Canada-Wide Standard reference method. The Canada-Wide Standard (CWS) method is used for the analysis of petroleum hydrocarbon compounds across Canada. However, inter-laboratory application of this method for the analysis of TPH in the soil has often shown considerable variability in the results. This could be due, in part, to the different gas chromatography (GC) conditions, other steps involved in the method, as well as the soil properties. In addition, there are differences in the interpretation of the GC results, which impacts the determination of the effectiveness of remediation at hydrocarbon-contaminated sites. In this work, multivariate experimental design approach was used to develop and validate the analytical method for a faster quantitative analysis of TPH in (contaminated) soil. A fractional factorial design (fFD) was used to screen six factors to identify the most significant factors impacting the analysis. These factors included: injection volume (μL), injection temperature (°C), oven program (°C/min), detector temperature (°C), carrier gas flow rate (mL/min) and solvent ratio (v/v hexane/dichloromethane). The most important factors (carrier gas flow rate and oven program) were then optimized using a central composite response surface design. Robustness testing and validation of model compares favourably with the experimental results with percentage difference of 2.78% for the analysis time. This research successfully reduced the method's standard analytical time from 20 to 8min with all the carbon fractions eluting. The method was successfully applied for fast TPH analysis of Bunker C oil contaminated soil. A reduced analytical time would offer many benefits including an improved laboratory reporting times, and overall improved clean up

  12. Bio-analytical method development and validation of Rasagiline by high performance liquid chromatography tandem mass spectrometry detection and its application to pharmacokinetic study

    Directory of Open Access Journals (Sweden)

    Ravi Kumar Konda

    2012-10-01

    Full Text Available The most suitable bio-analytical method based on liquid–liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm×50 mm, 3.5 μm column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The total run time was 3.0 min. The proposed method has been validated with the linear range of 5–12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3%–2.9% and 1.6%–2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition. Keywords: High performance liquid chromatography, Mass spectrometry, Rasagiline, Liquid–liquid extraction

  13. Determination of telmisartan in human blood plasma: Part II: Liquid chromatography-tandem mass spectrometry method development, comparison to immunoassay and pharmacokinetic study

    NARCIS (Netherlands)

    Hempen, C.M.; Gläsle-Schwarz, Liane; Kunz, Ulrich; Karst, U.

    2006-01-01

    A new liquid chromatography/atmospheric pressure chemical ionization-tandem mass spectrometry (LC/APCI-MS/MS) method with on-line sample clean-up for the determination of telmisartan in human blood plasma is presented. This technique is compared to a previously introduced enzyme-linked immunosorbent

  14. Development of a fast liquid chromatography-tandem mass spectrometry method for the determination of endocrine-disrupting compounds in waters.

    Science.gov (United States)

    Di Carro, Marina; Scapolla, Carlo; Liscio, Camilla; Magi, Emanuele

    2010-09-01

    A fast liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS-MS) method was developed to study five endocrine-disrupting compounds (4-n-nonylphenol, bisphenol A, estrone, 17β-estradiol and 17α-ethinylestradiol) in water. Different columns were tested; the chromatographic separation of the analytes was optimized on a Pinnacle DB biphenylic column with a water-acetonitrile gradient elution, which allowed the separation of the selected endocrine-disrupting compounds (EDCs) in less than 6 min. Quantitative analysis was performed in selected reaction monitoring (SRM) mode; two transitions were chosen for each compound, using the most abundant for quantitation. Calibration curves using bisphenol A-d (16) as internal standard were drawn, showing good correlation coefficients (0.9993-0.9998). All figures of merit of the method were satisfactory; limits of detection were in the low pg range for all analytes. The method was then applied to the determination of the analytes in real water samples: to this aim, polar organic chemical integrative samplers (POCIS) were deployed in the influent and in the effluent of a drinking water treatment plant in Liguria (Italy). The EDC level was rather low in the influent and negligible in the outlet, reflecting the expected function of the treatment plant.

  15. Method development for speciation analysis of nanoparticle and ionic forms of gold in biological samples by high performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Malejko, Julita; Świerżewska, Natalia; Bajguz, Andrzej; Godlewska-Żyłkiewicz, Beata

    2018-04-01

    A new method based on coupling high performance liquid chromatography (HPLC) to inductively coupled plasma mass spectrometry (ICP MS) has been developed for the speciation analysis of gold nanoparticles (AuNPs) and dissolved gold species (Au(III)) in biological samples. The column type, the composition and the flow rate of the mobile phase were carefully investigated in order to optimize the separation conditions. The usefulness of two polymeric reversed phase columns (PLRP-S with 100 nm and 400 nm pore size) to separate gold species were investigated for the first time. Under the optimal conditions (PLRP-S400 column, 10 mmol L-1 SDS and 5% methanol as the mobile phase, 0.5 mL min-1 flow rate), detection limits of 2.2 ng L-1 for Au(III), 2.8 ng L-1 for 10 nm AuNPs and 3.7 ng L-1 for 40 nm AuNPs were achieved. The accuracy of the method was proved by analysis of reference material RM 8011 (NIST) of gold nanoparticles of nominal diameter of 10 nm. The HPLC-ICP MS method has been successfully applied to the detection and size characterization of gold species in lysates of green algae Acutodesmus obliquus, typical representative of phytoplankton flora, incubated with 10 nm AuNPs or Au(III).

  16. Challenges and opportunities of using liquid chromatography and mass spectrometry methods to develop complex vaccine antigens as pharmaceutical dosage forms.

    Science.gov (United States)

    Hickey, John M; Sahni, Neha; Toth, Ronald T; Kumru, Ozan S; Joshi, Sangeeta B; Middaugh, C Russell; Volkin, David B

    2016-10-01

    Liquid chromatographic methods, combined with mass spectrometry, offer exciting and important opportunities to better characterize complex vaccine antigens including recombinant proteins, virus-like particles, inactivated viruses, polysaccharides, and protein-polysaccharide conjugates. The current abilities and limitations of these physicochemical methods to complement traditional in vitro and in vivo vaccine potency assays are explored in this review through the use of illustrative case studies. Various applications of these state-of-the art techniques are illustrated that include the analysis of influenza vaccines (inactivated whole virus and recombinant hemagglutinin), virus-like particle vaccines (human papillomavirus and hepatitis B), and polysaccharide linked to protein carrier vaccines (pneumococcal). Examples of utilizing these analytical methods to characterize vaccine antigens in the presence of adjuvants, which are often included to boost immune responses as part of the final vaccine dosage form, are also presented. Some of the challenges of using chromatographic and LC-MS as physicochemical assays to routinely test complex vaccine antigens are also discussed. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Development and validation of a rapid multi-biomarker liquid chromatography/tandem mass spectrometry method to assess human exposure to mycotoxins.

    Science.gov (United States)

    Warth, Benedikt; Sulyok, Michael; Fruhmann, Philipp; Mikula, Hannes; Berthiller, Franz; Schuhmacher, Rainer; Hametner, Christian; Abia, Wilfred Angie; Adam, Gerhard; Fröhlich, Johannes; Krska, Rudolf

    2012-07-15

    Mycotoxins regularly occur in food worldwide and pose serious health risks to consumers. Since individuals can be exposed to a variety of these toxic secondary metabolites of fungi at the same time, there is a demand for proper analytical methods to assess human exposure by suitable biomarkers. This study reports on the development of a liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for the quantitative measurement of 15 mycotoxins and key metabolites in human urine using polarity switching. Deoxynivalenol (DON), DON-3-O-glucuronide, DON-15-O-glucuronide (D15GlcA), de-epoxy DON, nivalenol (NIV), T-2 toxin, HT-2 toxin, zearalenone, zearalenone-14-O-glucuronide, α- and β-zearalenol, fumonisins B(1) and B(2) (FB(1), FB(2)), ochratoxin A (OTA) and aflatoxin M(1) (AFM(1)) were determined without the need for any cleanup using a rapid and simple dilute and shoot approach. Validation was performed in the range of 0.005-40 µg L(-1) depending on the analyte and expected urinary concentration levels. Apparent recoveries between 78 and 119% and interday precisions of 2-17% relative standard deviation (RSD) were achieved. The applicability of the method was demonstrated by the analysis of urine samples obtained from Cameroon. In naturally contaminated urine samples up to six biomarkers of exposure (AFM(1), DON, D15GlcA, NIV, FB(1), and OTA) were detected simultaneously. We conclude that the developed LC/MS/MS method is well suited to quantify multiple mycotoxin biomarkers in human urine down to the sub-ppb range within 18 min and without any prior cleanup. The co-occurrence of several mycotoxins in the investigated samples clearly emphasizes the great potential and importance of this method to assess exposure of humans and animals to naturally occurring mycotoxins. Copyright © 2012 John Wiley & Sons, Ltd.

  18. Development and validation of an ultra-high performance liquid chromatography-tandem mass spectrometry method to measure creatinine in human urine.

    Science.gov (United States)

    Fraselle, S; De Cremer, K; Coucke, W; Glorieux, G; Vanmassenhove, J; Schepers, E; Neirynck, N; Van Overmeire, I; Van Loco, J; Van Biesen, W; Vanholder, R

    2015-04-15

    Despite decades of creatinine measurement in biological fluids using a large variety of analytical methods, an accurate determination of this compound remains challenging. Especially with the novel trend to assess biomarkers on large sample sets preserved in biobanks, a simple and fast method that could cope with both a high sample throughput and a low volume of sample is still of interest. In answer to these challenges, a fast and accurate ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed to measure creatinine in small volumes of human urine. In this method, urine samples are simply diluted with a basic mobile phase and injected directly under positive electrospray ionization (ESI) conditions, without further purification steps. The combination of an important diluting factor (10(4) times) due to the use of a very sensitive triple quadrupole mass spectrometer (XEVO TQ) and the addition of creatinine-d3 as internal standard completely eliminates matrix effects coming from the urine. The method was validated in-house in 2012 according to the EMA guideline on bioanalytical method validation using Certified Reference samples from the German External Quality Assessment Scheme (G-Equas) proficiency test. All obtained results for accuracy and recovery are within the authorized tolerance ranges defined by G-Equas. The method is linear between 0 and 5 g/L, with LOD and LOQ of 5 × 10(-3) g/L and 10(-2) g/L, respectively. The repeatability (CV(r) = 1.03-2.07%) and intra-laboratory reproducibility (CV(RW) = 1.97-2.40%) satisfy the EMA 2012 guideline. The validated method was firstly applied to perform the German G-Equas proficiency test rounds 51 and 53, in 2013 and 2014, respectively. The obtained results were again all within the accepted tolerance ranges and very close to the reference values defined by the organizers of the proficiency test scheme, demonstrating an excellent accuracy of the developed method. The

  19. Development of a gas chromatography-mass spectrometry method for the determination of pesticides in gaseous and particulate phases in the atmosphere

    International Nuclear Information System (INIS)

    Borras, E.; Sanchez, P.; Munoz, A.; Tortajada-Genaro, L.A.

    2011-01-01

    Highlights: → An efficient method for the determination of sixteen pesticides in atmospheric samples. → XAD-4 is an interesting support for collecting gas-phase pesticides, with similar performances than the conventional XAD-2. → The ultrasonic extraction is cheaper, less aggressive and time-consuming with excellent analytical parameters. → The method has been successfully tested by using high volume atmospheric simulation chamber and field campaigns. - Abstract: A reliable multi-residue method for determining gaseous and particulate phase pesticides in atmospheric samples has been developed. This method, based on full scan gas chromatography-mass spectrometry (GC-MS), allowed the proper determination of sixteen relevant pesticides, in a wide range of concentrations and without the influence of interferences. The pesticides were benfluralin, bitertanol, buprofezin, chlorfenvinphos, chlorpyrifos, chlorpyrifos-methyl, ethalfluralin, fenthion, lindane, malathion, methidathion, propachlor, propanil, pyriproxifen, tebuconazol and trifluralin. Comparisons of two types of sampling filters (quartz and glass fibre) and four types of solid-phase cartridges (XAD-2, XAD-4, Florisil and Orbo-49P) showed that the most suitable supports were glass fibre filter for particulate pesticides and XAD-2 and XAD-4 cartridges for gaseous pesticides (>95% recovery). Evaluations of elution solvents for ultrasonic-assisted extraction demonstrated that isooctane is better than ethylacetate, dichloromethane, methanol or a mixture of acetone:hexane (1:1). Recovery assays and the standard addition method were performed to validate the proposed methodology. Moreover, large simulator chamber experiments allowed the best study of the gas-particle partitioning of pesticides for testing the sampling efficiency for the validation of an analytical multiresidue method for pesticides in air. Satisfactory analytical parameters were obtained, with a repeatability of 5 ± 1%, a reproducibility of 13

  20. Development of a method for the simultaneous determination of multi-class pesticides in earthworms by liquid chromatography coupled to tandem electrospray mass spectrometry.

    Science.gov (United States)

    Daniele, Gaëlle; Lafay, Florent; Pelosi, Céline; Fritsch, Clémentine; Vulliet, Emmanuelle

    2018-06-04

    Agricultural intensification, and in particular the use of pesticides, leads over the years to a loss of biodiversity and a decline of ecosystem services in cultivated zones and agricultural landscapes. Among the animal communities involved in the functioning of agro-ecosystems, earthworms are ubiquitous and recognized as indicators of land uses and cultural practices. However, little data is available on the levels of pesticides in such organisms in natura, which would allow estimating their actual exposure and the potentially resulting impacts. Thus, the objective of this study was to develop a sensitive analytical methodology to detect and quantify 27 currently used pesticides in earthworms (Allolobophora chlorotica). A modified QuEChERS extraction was implemented on individual earthworms. This step was followed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The whole analytical method was validated on spiked earthworm blank samples, with regard to linearity (from 1 to 100 method limit of quantification, r 2  > 0.95), intra-day precision (relative standard deviation (RSD) Graphical abstract.

  1. Analytical method development of nifedipine and its degradants binary mixture using high performance liquid chromatography through a quality by design approach

    Science.gov (United States)

    Choiri, S.; Ainurofiq, A.; Ratri, R.; Zulmi, M. U.

    2018-03-01

    Nifedipin (NIF) is a photo-labile drug that easily degrades when it exposures a sunlight. This research aimed to develop of an analytical method using a high-performance liquid chromatography and implemented a quality by design approach to obtain effective, efficient, and validated analytical methods of NIF and its degradants. A 22 full factorial design approach with a curvature as a center point was applied to optimize of the analytical condition of NIF and its degradants. Mobile phase composition (MPC) and flow rate (FR) as factors determined on the system suitability parameters. The selected condition was validated by cross-validation using a leave one out technique. Alteration of MPC affected on time retention significantly. Furthermore, an increase of FR reduced the tailing factor. In addition, the interaction of both factors affected on an increase of the theoretical plates and resolution of NIF and its degradants. The selected analytical condition of NIF and its degradants has been validated at range 1 – 16 µg/mL that had good linearity, precision, accuration and efficient due to an analysis time within 10 min.

  2. Development and validation of automatic HS-SPME with a gas chromatography-ion trap/mass spectrometry method for analysis of volatiles in wines.

    Science.gov (United States)

    Paula Barros, Elisabete; Moreira, Nathalie; Elias Pereira, Giuliano; Leite, Selma Gomes Ferreira; Moraes Rezende, Claudia; Guedes de Pinho, Paula

    2012-11-15

    An automated headspace solid-phase microextraction (HS-SPME) combined with gas chromatography-ion trap/mass spectrometry (GC-IT/MS) was developed in order to quantify a large number of volatile compounds in wines such as alcohols, ester, norisoprenoids and terpenes. The procedures were optimized for SPME fiber selection, pre-incubation temperature and time, extraction temperature and time, and salt addition. A central composite experimental design was used in the optimization of the extraction conditions. The volatile compounds showed optimal extraction using a DVB/CAR/PDMS fiber, incubation of 5 ml of wine with 2g NaCl at 45 °C during 5 min, and subsequent extraction of 30 min at the same temperature. The method allowed the identification of 64 volatile compounds. Afterwards, the method was validated successfully for the most significant compounds and was applied to study the volatile composition of different white wines. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Development of a magnetic solid-phase extraction coupled with high-performance liquid chromatography method for the analysis of polyaromatic hydrocarbons.

    Science.gov (United States)

    Ma, Yan; Xie, Jiawen; Jin, Jing; Wang, Wei; Yao, Zhijian; Zhou, Qing; Li, Aimin; Liang, Ying

    2015-07-01

    A novel magnetic solid phase extraction coupled with high-performance liquid chromatography method was established to analyze polyaromatic hydrocarbons in environmental water samples. The extraction conditions, including the amount of extraction agent, extraction time, pH and the surface structure of the magnetic extraction agent, were optimized. The results showed that the amount of extraction agent and extraction time significantly influenced the extraction performance. The increase in the specific surface area, the enlargement of pore size, and the reduction of particle size could enhance the extraction performance of the magnetic microsphere. The optimized magnetic extraction agent possessed a high surface area of 1311 m(2) /g, a large pore size of 6-9 nm, and a small particle size of 6-9 μm. The limit of detection for phenanthrene and benzo[g,h,i]perylene in the developed analysis method was 3.2 and 10.5 ng/L, respectively. When applied to river water samples, the spiked recovery of phenanthrene and benzo[g,h,i]perylene ranged from 89.5-98.6% and 82.9-89.1%, respectively. Phenanthrene was detected over a concentration range of 89-117 ng/L in three water samples withdrawn from the midstream of the Huai River, and benzo[g,h,i]perylene was below the detection limit. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Addressing the need for biomarker liquid chromatography/mass spectrometry assays: a protocol for effective method development for the bioanalysis of endogenous compounds in cerebrospinal fluid.

    Science.gov (United States)

    Benitex, Yulia; McNaney, Colleen A; Luchetti, David; Schaeffer, Eric; Olah, Timothy V; Morgan, Daniel G; Drexler, Dieter M

    2013-08-30

    Research on disorders of the central nervous system (CNS) has shown that an imbalance in the levels of specific endogenous neurotransmitters may underlie certain CNS diseases. These alterations in neurotransmitter levels may provide insight into pathophysiology, but can also serve as disease and pharmacodynamic biomarkers. To measure these potential biomarkers in vivo, the relevant sample matrix is cerebrospinal fluid (CSF), which is in equilibrium with the brain's interstitial fluid and circulates through the ventricular system of the brain and spinal cord. Accurate analysis of these potential biomarkers can be challenging due to low CSF sample volume, low analyte levels, and potential interferences from other endogenous compounds. A protocol has been established for effective method development of bioanalytical assays for endogenous compounds in CSF. Database searches and standard-addition experiments are employed to qualify sample preparation and specificity of the detection thus evaluating accuracy and precision. This protocol was applied to the study of the histaminergic neurotransmitter system and the analysis of histamine and its metabolite 1-methylhistamine in rat CSF. The protocol resulted in a specific and sensitive novel method utilizing pre-column derivatization ultra high performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS), which is also capable of separating an endogenous interfering compound, identified as taurine, from the analytes of interest. Copyright © 2013 John Wiley & Sons, Ltd.

  5. Development of a high performance liquid chromatography method for quantification of isomers β-caryophyllene and α-humulene in copaiba oleoresin using the Box-Behnken design.

    Science.gov (United States)

    de Almeida Borges, Vinícius Raphael; Ribeiro, Ana Ferreira; de Souza Anselmo, Carina; Cabral, Lúcio Mendes; de Sousa, Valéria Pereira

    2013-12-01

    The sesquiterpene isomers, β-Cariofileno (CAR) and α-Humuleno (HUM) are the primary constituents of the copaiba oleoresin species. These natural products are primarily used by the Amazonian population and marketed as phytotherapies and cosmetics. The aim of this study was to develop and validate a method that simultaneously assays the isomers present in copaiba oleoresins by high performance liquid chromatography using the Box-Behnken design. After preliminary studies, the reverse phase chromatographic system was selected using a cyano column and a mobile phase consisting of acetonitrile and phosphate buffer. The Box-Behnken design was applied at three levels and with four independent variables: flow rate (X1), gradient slope time (X2), proportion of organic compounds at the end of the gradient (X3) and at the beginning of the gradient (X4). Also, the responses of the dependent variables: CAR retention time (Y1) and the resolution between the CAR and HUM peaks (Y2) was assessed. The mathematical model obtained from the regression results was satisfactory (R(2)>0.98, n=27) and showed a quadratic relationship where the effects of interactions between the variables, was observed by response surface graphs. The simultaneous optimization method was used to establish the best compromise of the resolution between the CAR and HUM isomers while adjusting the retention time of CAR. This method was successfully optimized by BBD obtaining chromatographic peaks with good symmetry, resolution and separation efficiency. The validation of the developed method confirmed its specificity, precision, accuracy and linearity in the range of 5.0-11.0 and 0.4-1.0μg/mL for CAR and HUM, respectively, and is considered suitable for routine applications which assure quality control. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Development of a method for comprehensive and quantitative analysis of plant hormones by highly sensitive nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry

    International Nuclear Information System (INIS)

    Izumi, Yoshihiro; Okazawa, Atsushi; Bamba, Takeshi; Kobayashi, Akio; Fukusaki, Eiichiro

    2009-01-01

    In recent plant hormone research, there is an increased demand for a highly sensitive and comprehensive analytical approach to elucidate the hormonal signaling networks, functions, and dynamics. We have demonstrated the high sensitivity of a comprehensive and quantitative analytical method developed with nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry (LC-ESI-IT-MS/MS) under multiple-reaction monitoring (MRM) in plant hormone profiling. Unlabeled and deuterium-labeled isotopomers of four classes of plant hormones and their derivatives, auxins, cytokinins (CK), abscisic acid (ABA), and gibberellins (GA), were analyzed by this method. The optimized nanoflow-LC-ESI-IT-MS/MS method showed ca. 5-10-fold greater sensitivity than capillary-LC-ESI-IT-MS/MS, and the detection limits (S/N = 3) of several plant hormones were in the sub-fmol range. The results showed excellent linearity (R 2 values of 0.9937-1.0000) and reproducibility of elution times (relative standard deviations, RSDs, <1.1%) and peak areas (RSDs, <10.7%) for all target compounds. Further, sample purification using Oasis HLB and Oasis MCX cartridges significantly decreased the ion-suppressing effects of biological matrix as compared to the purification using only Oasis HLB cartridge. The optimized nanoflow-LC-ESI-IT-MS/MS method was successfully used to analyze endogenous plant hormones in Arabidopsis and tobacco samples. The samples used in this analysis were extracted from only 17 tobacco dry seeds (1 mg DW), indicating that the efficiency of analysis of endogenous plant hormones strongly depends on the detection sensitivity of the method. Our analytical approach will be useful for in-depth studies on complex plant hormonal metabolism.

  7. Development of a method for comprehensive and quantitative analysis of plant hormones by highly sensitive nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Izumi, Yoshihiro; Okazawa, Atsushi; Bamba, Takeshi; Kobayashi, Akio [Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan); Fukusaki, Eiichiro, E-mail: fukusaki@bio.eng.osaka-u.ac.jp [Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan)

    2009-08-26

    In recent plant hormone research, there is an increased demand for a highly sensitive and comprehensive analytical approach to elucidate the hormonal signaling networks, functions, and dynamics. We have demonstrated the high sensitivity of a comprehensive and quantitative analytical method developed with nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry (LC-ESI-IT-MS/MS) under multiple-reaction monitoring (MRM) in plant hormone profiling. Unlabeled and deuterium-labeled isotopomers of four classes of plant hormones and their derivatives, auxins, cytokinins (CK), abscisic acid (ABA), and gibberellins (GA), were analyzed by this method. The optimized nanoflow-LC-ESI-IT-MS/MS method showed ca. 5-10-fold greater sensitivity than capillary-LC-ESI-IT-MS/MS, and the detection limits (S/N = 3) of several plant hormones were in the sub-fmol range. The results showed excellent linearity (R{sup 2} values of 0.9937-1.0000) and reproducibility of elution times (relative standard deviations, RSDs, <1.1%) and peak areas (RSDs, <10.7%) for all target compounds. Further, sample purification using Oasis HLB and Oasis MCX cartridges significantly decreased the ion-suppressing effects of biological matrix as compared to the purification using only Oasis HLB cartridge. The optimized nanoflow-LC-ESI-IT-MS/MS method was successfully used to analyze endogenous plant hormones in Arabidopsis and tobacco samples. The samples used in this analysis were extracted from only 17 tobacco dry seeds (1 mg DW), indicating that the efficiency of analysis of endogenous plant hormones strongly depends on the detection sensitivity of the method. Our analytical approach will be useful for in-depth studies on complex plant hormonal metabolism.

  8. Development of a supercritical fluid chromatography-tandem mass spectrometry method for the determination of lacidipine in beagle dog plasma and its application to a bioavailability study.

    Science.gov (United States)

    Geng, Yajie; Zhao, Longshan; Zhao, Juanhang; Guo, Bei; Ma, Panqin; Li, Yuanyuan; Zhang, Tianhong

    2014-01-15

    A simple, novel, rapid and sensitive supercritical fluid chromatography-tandem mass spectrometry (SFC-MS/MS) method was developed and validated for the determination of lacidipine in beagle dog plasma with nimodipine as internal standard. The method involved a simple liquid-liquid extraction method with tert-butyl methyl ether. The analytes were analyzed on an Acquity UPC(2) with a HSS C18 SB column (3mm×100mm, 1.8μm) set at 50°C. The mobile phase was carbon dioxide (≥99.99%) and methanol (92:8, v/v) at a flow rate of 2ml/min, the compensation solvent was methanol with 2% formic acid at a flow rate of 0.2ml/min and a total analysis time of 1.5min for each sample. The multiple reaction-monitoring mode was used for quantification of ion transitions at m/z 473.32→354.10 and 419.00→343.10 for lacidipine and internal standard, respectively. The linearity range of proposed method was 0.10-100ng/ml) (r(2)≥0.9990). The intra- and inter-day precision values were less than 15% and accuracy was from -0.83% to 3.27% at all quality control levels. The proposed method was successfully applied to a pharmacokinetic study of lacidipine in beagle dogs. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Development of an Analytic Method for Sulfur Compounds in Aged Garlic Extract with the Use of a Postcolumn High Performance Liquid Chromatography Method with Sulfur-Specific Detection.

    Science.gov (United States)

    Matsutomo, Toshiaki; Kodera, Yukihiro

    2016-02-01

    Garlic and its processed preparations contain numerous sulfur compounds that are difficult to analyze in a single run using HPLC. The aim of this study was to develop a rapid and convenient sulfur-specific HPLC method to analyze sulfur compounds in aged garlic extract (AGE). We modified a conventional postcolumn HPLC method by employing a hexaiodoplatinate reagent. Identification and structural analysis of sulfur compounds were conducted by LC-mass spectrometry (LC-MS) and nuclear magnetic resonance. The production mechanisms of cis-S-1-propenylcysteine (cis-S1PC) and S-allylmercaptocysteine (SAMC) were examined by model reactions. Our method has the following advantages: less interference from nonsulfur compounds, high sensitivity, good correlation coefficients (r > 0.98), and high resolution that can separate >20 sulfur compounds, including several isomers, in garlic preparations in a single run. This method was adapted for LC-MS analysis. We identified cis-S1PC and γ-glutamyl-S-allyl-mercaptocysteine in AGE. The results of model reactions suggest that cis-S1PC is produced from trans-S1PC through an isomerization reaction and that SAMC is produced by a reaction involving S-allylcysteine/S1PC and diallyldisulfide during the aging period. We developed a rapid postcolumn HPLC method for both qualitative and quantitative analyses of sulfur compounds, and this method helped elucidate a potential mechanism of cis-S1PC and SAMC action in AGE. © 2016 American Society for Nutrition.

  10. Development of a new ultra-high performance liquid chromatography - tandem mass spectrometry method for determination of ambroxol hydrochloride in serum with pharmacokinetic application

    Directory of Open Access Journals (Sweden)

    Vujović Maja M.

    2016-01-01

    Full Text Available Ambroxol hydrochloride is an expectorant agent, successfully applied in mucolytic therapy for acute and chronic bronchopulmonary diseases. The drug regulates not only mucus secretion but also showed antioxidant, anti-inflammatory and local anesthetic properties. To supplement the pharmacokinetic and toxicological studies of ambroxol, a rapid ultra-high performance liquid chromatography-tandem mass spectrometry method for the quantitation of ambroxol in rabbit serum was developed. A validation of the method was performed as per the ICH guidelines for the validation of bioanalytical methods. The chromatographic separation was achieved in a submicron Kinetex RP - C18 - column (2.1 mm x 50 mm, 1.3μm using the no buffer mobile phase. The ESI mass spectrometry in the MRM mode was used with a typical transitions m/z 378.9→263.8 for ambroxol and m/z 455.2→165.0 for IS. Linearity was determined with an average coefficient of determination >0.999 over the dynamic range from 0.5 - 200 ng/mL with LOD and LOQ of 0.25 ng/mL and 0.5 ng/mL, respectively. The results of the intra- and inter-day precision and accuracy determined in different days were all found to be within the acceptable limits ±15%. The present method was successfully applied to pharmacokinetic study in the rabbits after a single oral dose administration. [Projekat Ministarstva nauke Republike Srbije, br. 175045

  11. Liquid chromatography-tandem mass spectrometry multiresidue method for the analysis of quaternary ammonium compounds in cheese and milk products: Development and validation using the total error approach.

    Science.gov (United States)

    Slimani, Kahina; Féret, Aurélie; Pirotais, Yvette; Maris, Pierre; Abjean, Jean-Pierre; Hurtaud-Pessel, Dominique

    2017-09-29

    Quaternary ammonium compounds (QACs) are both cationic surfactants and biocidal substances widely used as disinfectants in the food industry. A sensitive and reliable method for the analysis of benzalkonium chlorides (BACs) and dialkyldimethylammonium chlorides (DDACs) has been developed that enables the simultaneous quantitative determination of ten quaternary ammonium residues in dairy products below the provisional maximum residue level (MRL), set at 0.1mgkg -1 . To the best of our knowledge, this method could be the one applicable to milk and to three major processed milk products selected, namely processed or hard pressed cheeses, and whole milk powder. The method comprises solvent extraction using a mixture of acetonitrile and ethyl acetate, without any further clean-up. Analyses were performed by liquid chromatography coupled with electrospray tandem mass spectrometry detection (LC-ESI-MS/MS) operating in positive mode. A C18 analytical column was used for chromatographic separation, with a mobile phase composed of acetonitrile and water both containing 0.3% formic acid; and methanol in the gradient mode. Five deuterated internal standards were added to obtain the most accurate quantification. Extraction recoveries were satisfactory and no matrix effects were observed. The method was validated using the total error approach in accordance with the NF V03-110 standard in order to characterize the trueness, repeatability, intermediate precision and analytical limits within the range of 5-150μgkg -1 for all matrices. These performance criteria, calculated by e.noval ® 3.0 software, were satisfactory and in full accordance with the proposed provisional MRL and with the recommendations in the European Union SANTE/11945/2015 regulatory guidelines. The limit of detection (LOD) was low (ammoniums in foodstuffs from dairy industries at residue levels, and could be used for biocide residues monitoring plans and to measure the exposition consumer to biocides products

  12. Development of a gas chromatography-mass spectrometry method for the determination of pesticides in gaseous and particulate phases in the atmosphere.

    Science.gov (United States)

    Borrás, E; Sánchez, P; Muñoz, A; Tortajada-Genaro, L A

    2011-08-05

    A reliable multi-residue method for determining gaseous and particulate phase pesticides in atmospheric samples has been developed. This method, based on full scan gas chromatography-mass spectrometry (GC-MS), allowed the proper determination of sixteen relevant pesticides, in a wide range of concentrations and without the influence of interferences. The pesticides were benfluralin, bitertanol, buprofezin, chlorfenvinphos, chlorpyrifos, chlorpyrifos-methyl, ethalfluralin, fenthion, lindane, malathion, methidathion, propachlor, propanil, pyriproxifen, tebuconazol and trifluralin. Comparisons of two types of sampling filters (quartz and glass fibre) and four types of solid-phase cartridges (XAD-2, XAD-4, Florisil and Orbo-49P) showed that the most suitable supports were glass fibre filter for particulate pesticides and XAD-2 and XAD-4 cartridges for gaseous pesticides (>95% recovery). Evaluations of elution solvents for ultrasonic-assisted extraction demonstrated that isooctane is better than ethylacetate, dichloromethane, methanol or a mixture of acetone:hexane (1:1). Recovery assays and the standard addition method were performed to validate the proposed methodology. Moreover, large simulator chamber experiments allowed the best study of the gas-particle partitioning of pesticides for testing the sampling efficiency for the validation of an analytical multiresidue method for pesticides in air. Satisfactory analytical parameters were obtained, with a repeatability of 5±1%, a reproducibility of 13±3% and detection limits of 0.05-0.18 pg m(-3) for the particulate phase and 26-88 pg m(-3) for the gaseous phase. Finally, the methodology was successfully applied to rural and agricultural samples in the Mediterranean area. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Development and validation of an ultra high performance liquid chromatography tandem mass spectrometry method for simultaneous determination of sulfonamides, quinolones and benzimidazoles in bovine milk.

    Science.gov (United States)

    Hou, Xiao-Lin; Chen, Guo; Zhu, Li; Yang, Ting; Zhao, Jian; Wang, Lei; Wu, Yin-Liang

    2014-07-01

    A simple, sensitive and reliable analytical method was developed for the simultaneous determination of 38 veterinary drugs (18 sulfonamides, 11 quinolones and 9 benzimidazoles) and 8 metabolites of benzimidazoles in bovine milk by ultra high performance liquid chromatography-positive electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS). Samples were extracted with acidified acetonitrile, cleaned up with Oasis(®) MCX cartridges, and analyzed by LC-MS/MS on an Acquity UPLC(®) BEH C18 column with gradient elution. The method allows such multi-analyte measurements within a 13min runtime while the specificity is ensured through the MRM acquisition mode. The method was validated according to the European Commission Decision 2002/657/EC determining specificity, decision limit (CCα), detection capability (CCβ), recovery, precision, linearity and stability. For compounds which have MRLs in bovine milk, the CCα values fall into a range from 11 to 115μg/kg, and the CCβ values fall within a range of 12-125μg/kg. For compounds which have not MRLs in bovine milk, the CCα values fall into a range from 0.01 to 0.08μg/kg, and the CCβ values fall within a range of 0.02-0.11μg/kg. The mean recoveries of the 46 analytes were between 87 and 119%. The calculated RSD values of repeatability and within-laboratory reproducibility experiments were below 11% and 15% for the 46 compounds, respectively. The method was demonstrated to be suitable for the simultaneous determination of sulfonamides, quinolones and benzimidazoles in bovine milk. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Quality by design approach in the development of an ultra-high-performance liquid chromatography method for Bexsero meningococcal group B vaccine.

    Science.gov (United States)

    Nompari, Luca; Orlandini, Serena; Pasquini, Benedetta; Campa, Cristiana; Rovini, Michele; Del Bubba, Massimo; Furlanetto, Sandra

    2018-02-01

    Bexsero is the first approved vaccine for active immunization of individuals from 2 months of age and older to prevent invasive disease caused by Neisseria meningitidis serogroup B. The active components of the vaccine are Neisseria Heparin Binding Antigen, factor H binding protein, Neisseria adhesin A, produced in Escherichia coli cells by recombinant DNA technology, and Outer Membrane Vesicles (expressing Porin A and Porin B), produced by fermentation of Neisseria meningitidis strain NZ98/254. All the Bexsero active components are adsorbed on aluminum hydroxide and the unadsorbed antigens content is a product critical quality attribute. In this paper the development of a fast, selective and sensitive ultra-high-performance liquid chromatography (UHPLC) method for the determination of the Bexsero antigens in the vaccine supernatant is presented. For the first time in the literature, the Quality by Design (QbD) principles were applied to the development of an analytical method aimed to the quality control of a vaccine product. The UHPLC method was fully developed within the QbD framework, the new paradigm of quality outlined in International Conference on Harmonisation guidelines. Critical method attributes (CMAs) were identified with the capacity factor of Neisseria Heparin Binding Antigen, antigens resolution and peak areas. After a scouting phase, aimed at selecting a suitable and fast UHPLC operative mode for the vaccine antigens separation, risk assessment tools were employed to define the critical method parameters to be considered in the screening phase. Screening designs were applied for investigating at first the effects of vial type and sample concentration, and then the effects of injection volume, column type, organic phase starting concentration, ramp time and temperature. Response Surface Methodology pointed out the presence of several significant interaction effects, and with the support of Monte-Carlo simulations led to map out the design space, at

  15. Development of a quantitation method to assay both lyoniresinol enantiomers in wines, spirits, and oak wood by liquid chromatography-high resolution mass spectrometry.

    Science.gov (United States)

    Cretin, Blandine N; Dubourdieu, Denis; Marchal, Axel

    2016-05-01

    Wine taste balance evolves during oak aging by the release of volatile and non-volatile compounds from wood. Among them, an enantiomer of lyoniresinol, (+)-lyoniresinol, has been shown to exhibit bitterness. To evaluate the impact of (+)-lyoniresinol on wine taste, a two-step quantitation method was developed and validated. First, (±)-lyoniresinol was assayed in wines, spirits, and oak wood macerates by C-18 liquid chromatography-high resolution mass spectrometry (LC-HRMS). Then, the lyoniresinol enantiomeric ratio was determined by chiral LC-HRMS in order to calculate the (+)-lyoniresinol content. In red and white wines, the average concentrations of (+)-lyoniresinol were 1.9 and 0.8 mg/L, respectively. The enantiomer proportions were not affected by bottle aging, and lyoniresinol appeared to remain stable over time. The sensory study of (+)-lyoniresinol established its perception threshold at 0.46 mg/L in wine. All the commercial wines quantitated were above this perception threshold, demonstrating its impact on wine taste by an increase in bitterness. In spirits, (+)-lyoniresinol ranged from 2.0 to 10.0 mg/L and was found to be released continuously during oak aging. Finally, neither botanical origin nor toasting was found to significantly affect the (+)-lyoniresinol content of oak wood. Graphical abstract From oak wood to wine: evaluation of the influence of (+)-lyoniresinol on the bitterness of wines and spirits.

  16. Development and Validation of a Simple High Performance Liquid Chromatography/UV Method for Simultaneous Determination of Urinary Uric Acid, Hypoxanthine, and Creatinine in Human Urine

    Directory of Open Access Journals (Sweden)

    Nimanthi Wijemanne

    2018-01-01

    Full Text Available Uric acid and hypoxanthine are produced in the catabolism of purine. Abnormal urinary levels of these products are associated with many diseases and therefore it is necessary to have a simple and rapid method to detect them. Hence, we report a simple reverse phase high performance liquid chromatography (HPLC/UV technique, developed and validated for simultaneous analysis of uric acid, hypoxanthine, and creatinine in human urine. Urine was diluted appropriately and eluted with C-18 column 100 mm × 4.6 mm with a C-18 precolumn 25 mm × 4.6 mm in series. Potassium phosphate buffer (20 mM, pH 7.25 at a flow rate of 0.40 mL/min was employed as the solvent and peaks were detected at 235 nm. Tyrosine was used as the internal standard. The experimental conditions offered a good separation of analytes without interference of endogenous substances. The calibration curves were linear for all test compounds with a regression coefficient, r2>0.99. Uric acid, creatinine, tyrosine, and hypoxanthine were eluted at 5.2, 6.1, 7.2, and 8.3 min, respectively. Intraday and interday variability were less than 4.6% for all the analytes investigated and the recovery ranged from 98 to 102%. The proposed HPLC procedure is a simple, rapid, and low cost method with high accuracy with minimum use of organic solvents. This method was successfully applied for the determination of creatinine, hypoxanthine, and uric acid in human urine.

  17. Development and validation of an high-performance liquid chromatography-diode array detector method for the simultaneous determination of six phenolic compounds in abnormal savda munziq decoction

    Science.gov (United States)

    Tian, Shuge; Liu, Wenxian; Liu, Feng; Zhang, Xuejia; Upur, Halmuart

    2015-01-01

    Aims: Given the high-effectiveness and low-toxicity of abnormal savda munziq (ASMQ), its herbal formulation has long been used in traditional Uyghur medicine to treat complex diseases, such as cancer, diabetes, and cardiovascular diseases. Settings and Design: ASMQ decoction by reversed-phase high-performance liquid chromatography coupled with a diode array detector was successfully developed for the simultaneous quality assessment of gallic acid, protocatechuic acid, caffeic acid, rutin, rosmarinic acid, and luteolin. The six phenolic compounds were separated on an Agilent TC-C18 reversed-phase analytical column (4.6 × 250 mm, 5 μm) by gradient elution using 0.3% aqueous formic acid (v/v) and 0.3% methanol formic acid (v/v) at 1.0 mL/min. Materials and Methods: The plant material was separately ground and mixed at the following ratios (10): Cordia dichotoma (10.6), Anchusa italic (10.6), Euphorbia humifusa (4.9), Adiantum capillus-veneris (4.9), Ziziphus jujube (4.9), Glycyrrhiza uralensis (7.1), Foeniculum vulgare (4.9), Lavandula angustifolia (4.9), Dracocephalum moldavica L. (4.9), and Alhagi pseudoalhagi (42.3). Statistical Analysis Used: The precisions of all six compounds were Highly significant linear correlations were found between component concentrations and specific chromatographic peak areas (R2 > 0.999). Results: The proposed method was successfully applied to determine the levels of six active components in ASMQ. Conclusions: Given the simplicity, precision, specificity, and sensitivity of the method, it can be utilized as a quality control approach to simultaneously determining the six phenolic compounds in AMSQ. PMID:25709227

  18. Chromatography.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  19. Development of a liquid chromatography-electrospray chemical ionization tandem mass spectrometry analytical method for analysis of eleven hydroxylated polybrominated diphenyl ethers.

    Science.gov (United States)

    Feo, Maria Luisa; Barón, Enrique; Aga, Diana S; Eljarrat, Ethel; Barceló, Damià

    2013-08-02

    Recently, hydroxylated polybrominated diphenyl ethers (OH-PBDEs) have emerged as environmentally relevant pollutants due to recent reports of their natural production and metabolism. Recent mechanistic studies in human and rats have shown that some OH-PBDEs are more potent than parent compounds (PBDEs) and may contribute substantially to neurodevelopmental disorders by direct neurotoxicity, or indirectly through altered thyroid disruption. However, analytical methodologies for determination of OH-PBDEs are currently limited. In this study a robust liquid chromatography-electrospray tandem triple quadrupole-linear ion trap mass spectrometer (LC-ESI-QqLIT-MS-MS) in negative mode method was developed for the determination of eleven OH-tri- to OH-hexa-PBDEs. Two different columns were tested and compared for chromatographic separation: a C18 BetaBasic and a Purospher STAR RP 18, working at pH 8 and 10, respectively. Mobile phase (acetonitrile:water) was optimized by changing the pH of the aqueous phase and the concentration of the organic modifier (methanol). The MS-MS parameters (declustering potential (DP), collision energy (CE) and cell exit potential (CXP)) were optimized. Selected reaction monitoring (SRM) was used in order to increase sensitivity. Two SRM transitions ([M-H](-)>[Br](-)) were selected for each OH-PBDE, one for quantification and the second one for confirmation. Under the optimized conditions, the instrumental limits of detection were between 0.17 and 0.72injectedpg. The method provided good linearity (r>0.99 for a concentration range of 0.30-100ng/mL), accuracy and precision (%Dev and %RSD≤20% for intra- and inter-assays). Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Determination of endogenous concentrations of nitrites and nitrates in different types of cheese in the United States: method development and validation using ion chromatography.

    Science.gov (United States)

    Genualdi, Susan; Jeong, Nahyun; DeJager, Lowri

    2018-04-01

    Nitrites and nitrates can be present in dairy products from both endogenous and exogenous sources. In the European Union (EU), 150 mg kg - 1 of nitrates are allowed to be added to the cheese milk during the manufacturing process. The CODEX General Standard for Food Additives has a maximum permitted level of 50 mg kg - 1 residue in cheese, while in the United States (U.S.) nitrates are unapproved for use as food additives in cheese. In order to be able to investigate imported cheeses for nitrates intentionally added as preservatives and the endogenous concentrations of nitrates and nitrites present in cheeses in the U.S. marketplace, a method was developed and validated using ion chromatography with conductivity detection. A market sampling of cheese samples purchased in the Washington DC metro area was performed. In 64 samples of cheese, concentrations ranged from below the method detection limit (MDL) to 26 mg kg - 1 for nitrates and no concentrations of nitrites were found in any of the cheese samples above the MDL of 0.1 mg kg - 1 . A majority of the samples (93%) had concentrations below 10 mg kg - 1 , which indicate the presence of endogenous nitrates. The samples with concentrations above 10 mg kg - 1 were mainly processed cheese spread, which can contain additional ingredients often of plant-based origin. These ingredients are likely the cause of the elevated nitrate concentrations. The analysis of 12 additional cheese samples that are liable to the intentional addition of nitrates, 9 of which were imported, indicated that in this limited study, concentrations of nitrate in the U.S.-produced cheeses did not differ from those in imported samples.

  1. Development and validation of a liquid chromatography-tandem mass spectrometry method for topotecan determination in beagle dog plasma and its application in a bioequivalence study.

    Science.gov (United States)

    Ye, Ling; Shi, Jian; Wan, Shanhe; Yang, Xiaoshan; Wang, Ying; Zhang, Jiajie; Zheng, Dayong; Liu, Zhongqiu

    2013-11-01

    Topotecan (TPT) is an important anti-cancer drug that inhibits topoisomerase I. A sensitive and robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method that potentially determines TPT in beagle dog plasma is needed for a bioequivalence study of TPT formulations. We developed and validated LC-MS/MS to evaluate TPT in beagle dog plasma in terms of specificity, linearity, precision, accuracy, stability, extraction recovery and matrix effect. Plasma samples were treated with an Ostro(TM) sorbent plate (a robust and effective tool) to eliminate phospholipids and proteins before analysis. TPT and camptothecin (internal standard) were separated on an Acquity UPLC BEH C18 column (1.7 µm, 2.1 × 50 mm) with 0.1% formic acid and methanol as the mobile phase at a flow rate of 0.25 mL/min. TPT was analyzed using positive ion electrospray ionization in multiple-reaction monitoring mode. The obtained lower limit of quantitation was 1 ng/mL (signal-to-noise ratio > 10). The standard calibration curve for TPT was linear (correlation coefficient > 0.99) at the concentration range of 1-400 ng/mL. The intra-day and inter-day precision, accuracy, stability, extraction recovery and matrix effect of TPT were within the acceptable limits. The validated method was successfully applied in a bioequivalence study of TPT in healthy beagle dogs. Copyright © 2013 John Wiley & Sons, Ltd.

  2. Development and validation of a liquid chromatography-MS/MS method for simultaneous quantification of tenofovir and efavirenz in biological tissues and fluids.

    Science.gov (United States)

    Barreiros, Luisa; Cunha-Reis, Cassilda; Silva, Eduarda M P; Carvalho, Joana R B; das Neves, José; Sarmento, Bruno; Segundo, Marcela A

    2017-03-20

    Millions of people worldwide live with human immunodeficiency virus (HIV) infection thus justifying the continuous search for new prevention and treatment strategies, including topical microbicide products combining antiretroviral drugs (ARVs) such as tenofovir (TFV) and efavirenz (EFV). Therefore, the aim of this work was to develop and validate a high performance liquid chromatography method coupled to triple quadrupole-tandem mass spectrometry (HPLC-MS/MS) for the quantification of TFV and EFV in biological matrices (mouse vaginal tissue, vaginal lavage and blood plasma). Chromatographic separation was achieved using a reversed phase C18 column (3μm, 100×2.1mm) at 45°C and elution in gradient mode using a combination of 0.1% (v/v) formic acid in water and 0.1% (v/v) formic acid in acetonitrile at 0.35mLmin -1 . Total run time was 9min, with retention time of 2.8 and 4.1min for TFV and EFV, respectively. The MS was operated in positive ionization mode (ESI+) for TFV and in negative ionization mode (ESI-) for EFV detection. Data were acquired in selected reaction monitoring (SRM) mode and deuterated ARVs were employed as internal standards. Calibration curves were linear for ARV concentrations ranging from 4 to 500ngmL -1 with LOD and LOQ for both analytes ≤0.4 and ≤0.7ngmL -1 in sample extracts, respectively. The method was found to be specific, accurate (96.0-106.0% of nominal values) and precise (RSDfluids were ≥88.4%. Matrix effects were observed for EFV determination in tissue and plasma extracts but compensated by the use of deuterated internal standards. The proposed methodology was successfully applied to a pharmacokinetic study following intravaginal administration of both ARVs. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Analytical method for high resolution liquid chromatography for quality control French Macaw

    International Nuclear Information System (INIS)

    Garcia Penna, Caridad M; Torres Amaro, Leonid; Menendez Castillo, Rosa; Sanchez, Esther; Martinez Espinosa, Vivian; Gonzalez, Maria Lidia; Rodriguez, Carlos

    2007-01-01

    Was developed and validated an analytical method for high resolution liquid chromatography applicable to quality control of drugs dry French Macaw (Senna alata L. Roxb.) With ultraviolet detection at 340 nm. The method for high resolution liquid chromatography used to quantify the sennosides A and B, main components, was validated and proved to be specific, linear, precise and accurate. (Author)

  4. Development of a gas chromatography-mass spectrometry method for the determination of pesticides in gaseous and particulate phases in the atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Borras, E.; Sanchez, P.; Munoz, A. [Instituto Universitario Centro de Estudios Ambientales del Mediterraneo CEAM-UMH (Fundacion CEAM-UMH), 46980 Paterna, Valencia (Spain); Tortajada-Genaro, L.A., E-mail: luitorge@qim.upv.es [Instituto IDM, Departamento de Quimica, Universitat Politecnica de Valencia, Cami de Vera s/n 46022 Valencia (Spain)

    2011-08-05

    Highlights: {yields} An efficient method for the determination of sixteen pesticides in atmospheric samples. {yields} XAD-4 is an interesting support for collecting gas-phase pesticides, with similar performances than the conventional XAD-2. {yields} The ultrasonic extraction is cheaper, less aggressive and time-consuming with excellent analytical parameters. {yields} The method has been successfully tested by using high volume atmospheric simulation chamber and field campaigns. - Abstract: A reliable multi-residue method for determining gaseous and particulate phase pesticides in atmospheric samples has been developed. This method, based on full scan gas chromatography-mass spectrometry (GC-MS), allowed the proper determination of sixteen relevant pesticides, in a wide range of concentrations and without the influence of interferences. The pesticides were benfluralin, bitertanol, buprofezin, chlorfenvinphos, chlorpyrifos, chlorpyrifos-methyl, ethalfluralin, fenthion, lindane, malathion, methidathion, propachlor, propanil, pyriproxifen, tebuconazol and trifluralin. Comparisons of two types of sampling filters (quartz and glass fibre) and four types of solid-phase cartridges (XAD-2, XAD-4, Florisil and Orbo-49P) showed that the most suitable supports were glass fibre filter for particulate pesticides and XAD-2 and XAD-4 cartridges for gaseous pesticides (>95% recovery). Evaluations of elution solvents for ultrasonic-assisted extraction demonstrated that isooctane is better than ethylacetate, dichloromethane, methanol or a mixture of acetone:hexane (1:1). Recovery assays and the standard addition method were performed to validate the proposed methodology. Moreover, large simulator chamber experiments allowed the best study of the gas-particle partitioning of pesticides for testing the sampling efficiency for the validation of an analytical multiresidue method for pesticides in air. Satisfactory analytical parameters were obtained, with a repeatability of 5 {+-} 1%, a

  5. A review on development of analytical methods to determine monitorable drugs in serum and urine by micellar liquid chromatography using direct injection.

    Science.gov (United States)

    Esteve-Romero, Josep; Albiol-Chiva, Jaume; Peris-Vicente, Juan

    2016-07-05

    Therapeutic drug monitoring is a common practice in clinical studies. It requires the quantification of drugs in biological fluids. Micellar liquid chromatography (MLC), a well-established branch of Reverse Phase-High Performance Liquid Chromatography (RP-HPLC), has been proven by many researchers as a useful tool for the analysis of these matrices. This review presents several analytical methods, taken from the literature, devoted to the determination of several monitorable drugs in serum and urine by micellar liquid chromatography. The studied groups are: anticonvulsants, antiarrhythmics, tricyclic antidepressants, selective serotonin reuptake inhibitors, analgesics and bronchodilators. We detail the optimization strategy of the sample preparation and the main chromatographic conditions, such as the type of column, mobile phase composition (surfactant, organic solvent and pH), and detection. The finally selected experimental parameters, the validation, and some applications have also been described. In addition, their performances and advantages have been discussed. The main ones were the possibility of direct injection, and the efficient chromatographic elution, in spite of the complexity of the biological fluids. For each substance, the measured concentrations were accurate and precise at their respective therapeutic range. It was found that the MLC-procedures are fast, simple, inexpensive, ecofriendly, safe, selective, enough sensitive and reliable. Therefore, they represent an excellent alternative for the determination of drugs in serum and urine for monitoring purposes. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Development of an isotope labeling ultra-high performance liquid chromatography mass spectrometric method for quantification of acylglycines in human urine

    Energy Technology Data Exchange (ETDEWEB)

    Stanislaus, Avalyn; Guo, Kevin [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada); Li Liang, E-mail: Liang.Li@ualberta.ca [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada)

    2012-10-31

    Graphical abstract: - Abstract: Acylglycines play a crucial regulatory and detoxification role in the accumulation of the corresponding acyl CoA esters and are an important class of metabolites in the diagnoses of inborn errors of metabolism. Sensitive quantification of a large number of acylglycines not only improves diagnosis but also enables the discovery of potential new biomarkers of diseases. We report an ultra-high performance liquid chromatography tandem mass spectrometry (UPLC-MS) method for quantifying acylglycines in human urine with high sensitivity. This method is based on the use of a newly developed isotope labeling reagent, p-dimethylaminophenacyl (DmPA) bromide, to label acylglycines to improve detection sensitivity. Eighteen acylglycines, namely acetylglycine, propionylglycine, isobutyrylglycine, butyrylglycine, 4-hydroxyphenylacetylglycine, 2-furoylglycine, tiglylglycine, 2-methybutyrylglycine, 3-methylcrotonylglycine, isovalerylglycine, valerylglycine, hexanoylglycine, phenylacetylglycine, phenylpropionylglycine, glutarylglycine, heptanoylglycine, octanoylglycine and suberylglycine, were measured. This method uses calibration standards prepared in surrogate matrix (un-derivatized urine) and stable-isotope labeled analytes as the internal standards. The analysis was carried out in the positive ion detection mode using multiple reaction monitoring (MRM) survey scans. The calibration curves were validated over the range of 1.0-500 nM. The method achieved a lower limit of quantitation (LLOQ) of 1-5 nM for all analytes, as measured by the standard derivations associated with calibration curves and confirmed in surrogate matrix; the signal-to-noise ratio at LLOQ ranged from 12.50 to 156.70. Both accuracy (% RE or relative error) and precision (% CV) were <15%. Matrix effects were minimized using the surrogate matrix. All eighteen analytes were stable in urine for at least 5 h at room temperature, autosampler (4 Degree-Sign C) for 24 h, 7 weeks at -20

  7. Development of a new screening method for the detection of antibiotic residues in muscle tissues using liquid chromatography and high resolution mass spectrometry with a LC-LTQ-Orbitrap instrument.

    OpenAIRE

    2011-01-01

    Abstract In the present work, a liquid chromatography- high resolution mass spectrometry method was developed for the screening in meat of a wide range of antibiotics used in veterinary medicine. Full scan mode under high resolution mass spectral conditions using LTQ-Orbitrap mass spectrometer with resolving power 60.000 FWHM was applied for analysis of the samples. Samples were prepared using two extractions protocols prior to LC-MS analysis. The scope of the method focuses on the...

  8. Development and validation of a liquid chromatography tandem mass spectrometry method for the determination of cannabinoids and phase I and II metabolites in meconium.

    Science.gov (United States)

    Prego-Meleiro, Pablo; Lendoiro, Elena; Concheiro, Marta; Cruz, Angelines; López-Rivadulla, Manuel; de Castro, Ana

    2017-05-12

    A liquid chromatography-tandem mass spectrometry (LC-MSMS) method was developed and fully validated for the determination of Δ 9 -tetrahydrocannabinol (THC), 11-hydroxyTHC (OHTHC), 11-nor-9-carboxyTHC (THCCOOH), 8-β-11-dihydroxyTHC (diOHTHC), cannabinol, cannabidiol, and THC and THCCOOH glucuronides in 0.25±0.02g meconium. Samples were homogenized in methanol and subjected to cation exchange solid-phase extraction. Chromatographic separation was performed on a Kinetex C18 column (50 mm×2.1mm, 2.6μm) at 35°C, with a gradient of 0.1% formic acid in water and acetonitrile at a flow rate of 0.3 mL/min; total run time was 10min. Two transitions per analyte were monitored in MRM mode. The method was specific and sensitive; LOD was from 1 to 2ng/g, and LOQ from 4 to 10ng/g; linearity ranged from 4 to 400 ng/g for all the analytes, except for THC glucuronide (10-400ng/g); intra-assay, inter-assay and total imprecision were <11.2%, <13.45% and <15.6%, respectively; accuracy ranged from 93.9% to 109.0% of the target concentration; matrix effect, extraction and process efficiency ranged from -26.4% to -71.4%, 49.9% to 69.5% and 14.3% to 45.0%, respectively. The inclusion of THC and THCCOOH glucuronides avoided the need for the hydrolysis process, thus facilitating sample pretreatment. Application of the method to 19 authentic meconium specimens from uncontrolled pregnancies or women suspicious of drug consumption revealed fetal cannabis exposure in 4 newborns. THCCOOH (24.1-288.8ng/g), diOHTHC (53.2-332.4ng/g), THC (4.2-7.7ng/g), CBN (30.7-93.3ng/g) and CBD (7.1-251.5ng/g) were detected in all cases; THCCOOH glucuronide (190.2-306.8ng/g) in 3 cases; and OHTHC (11.9ng/g) in the remaining one; however, THC glucuronide was not identified in any specimen. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Development and validation of confirmatory method for analysis of nitrofuran metabolites in milk, honey, poultry meat and fish by liquid chromatography-mass spectrometry

    Directory of Open Access Journals (Sweden)

    Fatih Alkan

    2016-03-01

    Full Text Available In this study we have devoloped and validated a confirmatory analysis method for nitrofuran metabolites, which is in accordance with European Commission Decision 2002/657/EC requirements. Nitrofuran metabolites in honey, milk, poultry meat and fish samples were acidic hydrolised followed by derivatisation with nitrobenzaldehyde and liquid-liquid extracted with ethylacetate. The quantitative and confirmative determination of nitrofuran metbolites was performed by liquid chromatography/electrospray ionisation tandem mass spectrometry (LC/ESI-MS/MS in the positive ion mode. In-house method validation was performed and reported data of validation (specificity, linearity, recovery, CCα and CCβ. The advantage of this method is that it avoids the use of clean-up by Solid-Phase Extraction (SPE. Furthermore, low levels of nitrofuran metabolites are detectable and quantitatively confirmed at a rapid rate in all samples.

  10. Development and validation of a rapid ultra-high performance liquid chromatography diode array detector method for Vitex agnus-castus.

    Science.gov (United States)

    Högner, C; Sturm, S; Seger, C; Stuppner, H

    2013-05-15

    A rapid ultra-high performance liquid chromatography diode array detector (UHPLC-DAD) method was developed and validated for the simultaneous determination of all classes of non-volatile phytochemicals (iridoids, flavonoids and diterpenes) in Vitex agnus-castus (Lamiaceae) fruits, a traditional medicinal plant used against premenstrual symptoms (PMS) and other disorders. Seven marker compounds, 3,4-dihydroxybenzoic acid, p-hydroxybenzoic acid, agnuside, 5-hydroxykaempferol-3,6,7,4'-tetramethylether, 1,2-dibenzoic acid glucose, methoxy-vitexilactone, and vitetrifolin D were isolated from the methanol extract of V. agnus-castus to be used as reference substances. Chromatographic separation was performed on a Zorbax Eclipse XDB-C18 (50mm×2.1mm) UHPLC column with 1.8μm particle size, within 20min. A solvent gradient from 0.5% acetic acid to acetonitrile at a flow rate of 0.6mL/min was used as mobile phase. Analyte detection and quantification was realized at 210nm and 260nm. The UHPLC-DAD assay was validated for the quantitative analysis of agnuside, isovitexin, casticin, 5-hydroxykaempferol-3,6,7,4'-tetramethylether and vitetrifolin D. It was found to be specific, accurate, precise, and reproducible for the quantification of these compound within a concentration range of 0.7-500.0μg/mL for casticin and 5-hydroxykaempferol-3,6,7,4'-tetramethylether, 1.4-1000.0μg/mL for isovitexin and agnuside, and 12.4-1000.0μg/mL for vitetrifolin D. Intra- and inter-day variations showed relative standard deviations (RSD) of less than 3.9% and 6.4%, respectively. Tentatively assignment of 62 chromatographic features found in the UHPLC-DAD assay was carried out by coupling the UHPLC instrument to a quadrupole time-of-flight mass spectrometer via an electrospray ionization interface (ESI-QTOF-MS) operated in positive and negative ion mode. By using the established quantitative UHPLC-DAD assay to asses agnuside, isovitexin, casticin, 5-hydroxykaempferol-3,6,7,4'-tetramethylether and

  11. Development of a supercritical fluid chromatography method with ultraviolet and mass spectrometry detection for the characterization of biomass fast pyrolysis bio oils.

    Science.gov (United States)

    Crepier, Julien; Le Masle, Agnès; Charon, Nadège; Albrieux, Florian; Heinisch, Sabine

    2017-08-11

    The characterization of complex mixtures is a challenging issue for the development of innovative processes dedicated to biofuels and bio-products production. The huge number of compounds present in biomass fast pyrolysis oils combined with the large diversity of chemical functions represent a bottleneck as regards analytical technique development. For the extensive characterization of complex samples, supercritical fluid chromatography (SFC) can be alternative to usual separation techniques such as gas (GC) or liquid chromatography (LC). In this study, an approach is proposed to define the best conditions for the SFC separation of a fast pyrolysis bio-oil. This approach was based on SFC data obtained directly from the bio-oil itself instead of selecting model compounds as usually done. SFC conditions were optimized by using three specific, easy-to-use and quantitative criteria aiming at maximizing the separation power. Polar stationary phases (ethylpyridine bonded silica) associated to a mix of acetonitrile and water as polarity modifier provided the best results, with more than 120 peaks detected in SFC-UV. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Development and validation of a rapid high performance liquid chromatography - photodiode array detection method for estimation of a bioactive compound wedelolactone in extracts of Eclipta alba

    Directory of Open Access Journals (Sweden)

    Satyanshu Kumar

    2013-03-01

    Full Text Available Following optimization of extraction, separation and analytical conditions, a rapid, sensitive and simple reverse-phase high performance liquid chromatography-photo diode array (HPLC-PDA method has been developed for the identification and quantification of wedelolactone in different extracts of Eclipta alba. The separation of wedelolactone was achieved on a C18 column using the solvent system consisting of a mixture of methanol: water: acetic acid (95: 5: 0.04 as a mobile phase in isocratic elution mode followed by photo diode array detection at 352 nm. The developed method was validated as per the guidelines of the International Conference on Harmonization (ICH. Calibration curve presented good linear regression (r²>0.998 within the test range and the maximum relative standard deviation (RSD, % values for intra-day assay were found to be 0.15, 1.30 and 1.1 for low (5 µg/mL, medium (20 µg/mL and high (80 µg/mL concentrations of wedelolactone. For inter-day assay the maximum RSD (% values were found to be 2.83, 1.51 and 2.06 for low, medium and high concentrations, respectively. Limit of detection (LOD and limit of quantification (LOQ were calculated to be 2 and 5 µg/mL respectively. Analytical recovery of wedelolactone was greater than 95%. Wedelolactone in different extracts of Eclipta alba was identified and quantified using the developed HPLC method. The validated HPLC method allowed precise quantitative analysis of wedelolactone in Eclipta. alba extracts.Desenvolveu-se método rápido, sensível e simples de Cromatografia Líquida de Alta Eficiência em fase reversa, utilizando-se arranjo de fotodiodo (HPLC-PDA, visando à separação, extração e às condições analíticas para a identificação e quantificação de wedelolactona em diferentes extratos de Eclipta alba. A separação de wedelolactona foi efetuada por meio de uma coluna C18, utilizando mistura de metanol:água:ácido acético (95:5:0.04 como fase móvel, em sistema de

  13. Development of an analytical method for the determination of polybrominated diphenyl ethers in sewage sludge by the use of gas chromatography coupled to inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Novak, Petra; Zuliani, Tea; Milačič, Radmila; Ščančar, Janez

    2016-01-01

    Polybrominated diphenyl ethers (PBDEs) are flame retardants. As a consequence of their widespread use, they have been released into the environment. PBDEs are lipophilic organic contaminants that enter wastewater treatment plants (WWTPs) from urban, agricultural and industrial discharges. Because of their low aqueous solubility and resistance to biodegradation, up to 90% of the PBDEs are accumulated in the sewage sludge during the wastewater treatment. To assess the possibilities for sludge re-use, a reliable determination of the concentrations of these PBDEs is of crucial importance. Six PBDE congeners (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153 and BDE 154) are listed as priority substances under the EU Water Framework Directive. In the present work a simple analytical method with minimal sample-preparation steps was developed for a sensitive and reliable determination of the six PBDEs in sewage sludge by the use of gas chromatography coupled to inductively coupled plasma mass spectrometry (GC-ICP-MS). For this purpose an extraction procedure was optimised. Different extracting agents (methanol (MeOH), acetic acid (AcOH)/MeOH mixture (3:1) and 0.1 mol L"−"1 hydrochloric acid (HCl) in MeOH) followed by the addition of a Tris-citrate buffer (co-extracting agent) and iso-octane were applied under different modes of extraction (mechanical shaking, microwave- and ultrasound-assisted extraction). Mechanical shaking or the microwave-assisted extraction of sewage sludge with 0.1 mol L"−"1 HCl in MeOH and the subsequent addition of the Tris-citrate buffer and the iso-octane extracted the PBDEs from the complex sludge matrix most effectively. However, due to easier sample manipulation during the extraction step, mechanical shaking was used. The PBDEs in the organic phase were quantified with GC-ICP-MS by applying a standard addition calibration method. The spike recovery test (recoveries between 95 and 104%) and comparative analyses with the species-specific isotope

  14. Development of an analytical method for the determination of polybrominated diphenyl ethers in sewage sludge by the use of gas chromatography coupled to inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Novak, Petra [Department of Environmental Sciences, Jožef Stefan Institute, Jamova 39, 1000, Ljubljana (Slovenia); Jožef Stefan International Postgraduate School, Jamova 39, 1000, Ljubljana (Slovenia); Zuliani, Tea [Department of Environmental Sciences, Jožef Stefan Institute, Jamova 39, 1000, Ljubljana (Slovenia); Milačič, Radmila [Department of Environmental Sciences, Jožef Stefan Institute, Jamova 39, 1000, Ljubljana (Slovenia); Jožef Stefan International Postgraduate School, Jamova 39, 1000, Ljubljana (Slovenia); Ščančar, Janez, E-mail: janez.scancar@ijs.si [Department of Environmental Sciences, Jožef Stefan Institute, Jamova 39, 1000, Ljubljana (Slovenia); Jožef Stefan International Postgraduate School, Jamova 39, 1000, Ljubljana (Slovenia)

    2016-04-07

    Polybrominated diphenyl ethers (PBDEs) are flame retardants. As a consequence of their widespread use, they have been released into the environment. PBDEs are lipophilic organic contaminants that enter wastewater treatment plants (WWTPs) from urban, agricultural and industrial discharges. Because of their low aqueous solubility and resistance to biodegradation, up to 90% of the PBDEs are accumulated in the sewage sludge during the wastewater treatment. To assess the possibilities for sludge re-use, a reliable determination of the concentrations of these PBDEs is of crucial importance. Six PBDE congeners (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153 and BDE 154) are listed as priority substances under the EU Water Framework Directive. In the present work a simple analytical method with minimal sample-preparation steps was developed for a sensitive and reliable determination of the six PBDEs in sewage sludge by the use of gas chromatography coupled to inductively coupled plasma mass spectrometry (GC-ICP-MS). For this purpose an extraction procedure was optimised. Different extracting agents (methanol (MeOH), acetic acid (AcOH)/MeOH mixture (3:1) and 0.1 mol L{sup −1} hydrochloric acid (HCl) in MeOH) followed by the addition of a Tris-citrate buffer (co-extracting agent) and iso-octane were applied under different modes of extraction (mechanical shaking, microwave- and ultrasound-assisted extraction). Mechanical shaking or the microwave-assisted extraction of sewage sludge with 0.1 mol L{sup −1} HCl in MeOH and the subsequent addition of the Tris-citrate buffer and the iso-octane extracted the PBDEs from the complex sludge matrix most effectively. However, due to easier sample manipulation during the extraction step, mechanical shaking was used. The PBDEs in the organic phase were quantified with GC-ICP-MS by applying a standard addition calibration method. The spike recovery test (recoveries between 95 and 104%) and comparative analyses with the species

  15. Development of method for determination of Sodium monochloroacetate and sodium dichloroacetate in Cocoamido Propyl Betaine by gas chromatography: FID, ECD and MS

    International Nuclear Information System (INIS)

    Leao, Claudio; Redigolo, Marcelo Miyada; Amaral, Priscila Oliveira; Bustillos, Oscar Vega

    2015-01-01

    Cocoamide Propyl Betaine is a feedstock for consumer products of cosmetic and household segments. Sodium monochloroacetate and sodium dichloroacetate impurities are toxic, irritating and harmful to the environment and lower concentrations - parts per million level - are required in process control of producers and regulatory affairs. Regarding analytical test method, two conditions should be met: quantification limit, precision and accuracy should be appropriate; different techniques for gas chromatography - ECD, FID and MS - should be available, since for manufacturer is not so easy to keep electron capture detector by radioactive source Ni 63 due to government control and need of qualified radiological protection. The samples are obtained at manufacturers; for the analyte separation, treatment methodologies are employed by liquid-liquid extraction and solid phase extraction. Alternative detectors used in this study are: Flame Ionization and Mass Spectrometer with Electron Ionization. The validation process will be applied to methodology to ensure a selective, robust, accurate and reproducible analytical determination. (author)

  16. Development of method for determination of Sodium monochloroacetate and sodium dichloroacetate in Cocoamido Propyl Betaine by gas chromatography: FID, ECD and MS

    Energy Technology Data Exchange (ETDEWEB)

    Leao, Claudio; Redigolo, Marcelo Miyada; Amaral, Priscila Oliveira; Bustillos, Oscar Vega, E-mail: claudio.leao@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Cocoamide Propyl Betaine is a feedstock for consumer products of cosmetic and household segments. Sodium monochloroacetate and sodium dichloroacetate impurities are toxic, irritating and harmful to the environment and lower concentrations - parts per million level - are required in process control of producers and regulatory affairs. Regarding analytical test method, two conditions should be met: quantification limit, precision and accuracy should be appropriate; different techniques for gas chromatography - ECD, FID and MS - should be available, since for manufacturer is not so easy to keep electron capture detector by radioactive source Ni 63 due to government control and need of qualified radiological protection. The samples are obtained at manufacturers; for the analyte separation, treatment methodologies are employed by liquid-liquid extraction and solid phase extraction. Alternative detectors used in this study are: Flame Ionization and Mass Spectrometer with Electron Ionization. The validation process will be applied to methodology to ensure a selective, robust, accurate and reproducible analytical determination. (author)

  17. Development of On-Line High Performance Liquid Chromatography (HPLC)-Biochemical Detection Methods as Tools in the Identification of Bioactives

    Science.gov (United States)

    Malherbe, Christiaan J.; de Beer, Dalene; Joubert, Elizabeth

    2012-01-01

    Biochemical detection (BCD) methods are commonly used to screen plant extracts for specific biological activities in batch assays. Traditionally, bioactives in the most active extracts were identified through time-consuming bio-assay guided fractionation until single active compounds could be isolated. Not only are isolation procedures often tedious, but they could also lead to artifact formation. On-line coupling of BCD assays to high performance liquid chromatography (HPLC) is gaining ground as a high resolution screening technique to overcome problems associated with pre-isolation by measuring the effects of compounds post-column directly after separation. To date, several on-line HPLC-BCD assays, applied to whole plant extracts and mixtures, have been published. In this review the focus will fall on enzyme-based, receptor-based and antioxidant assays. PMID:22489144

  18. Development of a perfusion reversed-phase high performance liquid chromatography method for the characterisation of maize products using multivariate analysis.

    Science.gov (United States)

    Rodriguez-Nogales, J M; Garcia, M C; Marina, M L

    2006-02-03

    A perfusion reversed-phase high performance liquid chromatography (RP-HPLC) method has been designed to allow rapid (3.4 min) separations of maize proteins with high resolution. Several factors, such as extraction conditions, temperature, detection wavelength and type and concentration of ion-pairing agent were optimised. A fine optimisation of the gradient elution was also performed by applying experimental design. Commercial maize products for human consumption (flours, precocked flours, fried snacks and extruded snacks) were characterised for the first time by perfusion RP-HPLC and their chromatographic profiles allowed a differentiation among products relating the different technological process used for their preparation. Furthermore, applying discriminant analysis makes it possible to group the samples according with the technological process suffered by maize products, obtaining a good prediction in 92% of the samples.

  19. Qualitative and quantitative determination of ubiquinones by the method of high-efficiency liquid chromatography

    International Nuclear Information System (INIS)

    Yanotovskii, M.T.; Mogilevskaya, M.P.; Obol'nikova, E.A.; Kogan, L.M.; Samokhvalov, G.I.

    1986-01-01

    A method has been developed for the qualitative and quantitative determination of ubiquinones CoQ 6 -CoQ 10 , using high-efficiency reversed-phase liquid chromatography. Tocopherol acetate was used as the internal standard

  20. Development of a sensitive method for the determination of acrylamide in coffee using high-performance liquid chromatography coupled to a hybrid quadrupole Orbitrap mass spectrometer.

    Science.gov (United States)

    Pugajeva, Iveta; Jaunbergs, Janis; Bartkevics, Vadims

    2015-01-01

    The emerging trend towards high-resolution mass spectrometry (MS) alternatives was evaluated by the application of Orbitrap MS for the determination of acrylamide in coffee samples. The high resolving power of the Orbitrap MS provided the high selectivity and sensitivity that enabled quantitative analysis of acrylamide in complex matrices, such as coffee. Several sample preparation methods and scanning modes of the MS (full MS, t-SIM, t-MS2) were assessed in order to optimise parameters of the analytical method. The final procedure involved the extraction of acrylamide with acetonitrile, solid-phase extraction with dispersive primary secondary amine (PSA) and amino columns, and the detection by ultra-performance liquid chromatography coupled to a hybrid quadrupole-Orbitrap MS (HPLC-Q-Orbitrap) operated in targeted MS2 scanning mode. The repeatability of the method at the lowest calibration level (10 μg kg(-1)), expressed as relative standard deviation, was 7.8% and the average recovery of acrylamide was 111%. The proposed method was applied to the determination of acrylamide in 22 samples of roasted coffee obtained from the Latvian retail market. Acrylamide concentration in coffee samples was in the range of 166-503 μg kg(-1).

  1. Compound-Specific Chlorine Isotope Analysis of Tetrachloromethane and Trichloromethane by Gas Chromatography-Isotope Ratio Mass Spectrometry vs Gas Chromatography-Quadrupole Mass Spectrometry: Method Development and Evaluation of Precision and Trueness.

    Science.gov (United States)

    Heckel, Benjamin; Rodríguez-Fernández, Diana; Torrentó, Clara; Meyer, Armin; Palau, Jordi; Domènech, Cristina; Rosell, Mònica; Soler, Albert; Hunkeler, Daniel; Elsner, Martin

    2017-03-21

    Compound-specific chlorine isotope analysis of tetrachloromethane (CCl 4 ) and trichloromethane (CHCl 3 ) was explored by both, gas chromatography-isotope ratio mass spectrometry (GC-IRMS) and GC-quadrupole MS (GC-qMS), where GC-qMS was validated in an interlaboratory comparison between Munich and Neuchâtel with the same type of commercial GC-qMS instrument. GC-IRMS measurements analyzed CCl isotopologue ions, whereas GC-qMS analyzed the isotopologue ions CCl 3 , CCl 2 , CCl (of CCl 4 ) and CHCl 3 , CHCl 2 , CHCl (of CHCl 3 ), respectively. Lowest amount dependence (good linearity) was obtained (i) in H-containing fragment ions where interference of 35 Cl- to 37 Cl-containing ions was avoided; (ii) with tuning parameters favoring one predominant rather than multiple fragment ions in the mass spectra. Optimized GC-qMS parameters (dwell time 70 ms, 2 most abundant ions) resulted in standard deviations of 0.2‰ (CHCl 3 ) and 0.4‰ (CCl 4 ), which are only about twice as large as 0.1‰ and 0.2‰ for GC-IRMS. To compare also the trueness of both methods and laboratories, samples from CCl 4 and CHCl 3 degradation experiments were analyzed and calibrated against isotopically different reference standards for both CCl 4 and CHCl 3 (two of each). Excellent agreement confirms that true results can be obtained by both methods provided that a consistent set of isotopically characterized reference materials is used.

  2. Development and validation of a QuEChERS method coupled to liquid chromatography and high resolution mass spectrometry to determine pyrrolizidine and tropane alkaloids in honey.

    Science.gov (United States)

    Martinello, Marianna; Borin, Alice; Stella, Roberto; Bovo, Davide; Biancotto, Giancarlo; Gallina, Albino; Mutinelli, Franco

    2017-11-01

    Awareness about pyrrolizidine alkaloids (PAs) and tropane alkaloids (TAs) in food was recently raised by the European Food Safety Authority stressing the lack of data and gaps of knowledge required to improve the risk assessment strategy. The present study aimed at the elaboration and validation of a method to determine PAs and TAs in honey. QuEChERS sample treatment and liquid chromatography coupled to hybrid high resolution mass spectrometry, were used. The method resulted in good linearity (R 2 >0.99) and low limits of detection and quantification, ranging from 0.04 to 0.2µgkg -1 and from 0.1 to 0.7µgkg -1 respectively. Recoveries ranged from 92.3 to 114.8% with repeatability lying between 0.9 and 15.1% and reproducibility between 1.1 and 15.6%. These performances demonstrate the selectivity and sensitivity of the method for simultaneous trace detection and quantification of PAs and TAs in honey, verified through the analysis of forty commercial samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Multiresidue screening method for detection of benzimidazoles and their metabolites in liver and muscle by high-performance liquid chromatography: method development and validation according to Commission Decision 2002/657/EC

    Directory of Open Access Journals (Sweden)

    Marilena Gili

    2014-02-01

    Full Text Available The use of veterinary drugs may cause the presence of residues in food of animal origin if appropriate withdrawal periods are not respected. A high-performance liquid chromatography (HPLC method has been developed for the simultaneous detection of 11 benzimidazole residues, including metabolites – albendazole, albendazole sulphoxide, albendazole sulphone, fenbendazole, fenbendazole sulphoxide (oxfendazole, fenbendazole sulphone, flubendazole, mebendazole, oxibendazole, thiabendazole, 5-hydroxythiabendazole – in bovine, ovine, equine, swine, rabbit and poultry liver and in bovine, swine and fish muscle. After extraction with a dicloromethane/acetonitrile solution (35/65 v/v containing 5% ammonium hydroxide, the solvent was evaporated to dryness, the residue was dissolved in HCl 0.1 M, defatted with hexane, purified on a strong cation exchange solid-phase extraction cartridge and analysed in HPLC with diode array and fluorescence detectors. The method was validated as screening qualitative method evaluating, according to Commission Decision 2002/657/EC criteria, specificity, CCb and b error at cut off level of 25 mg/kg and ruggedness.

  4. Method development for determination of herbicides and insecticides in surface waters using solid-phase extraction and high performance liquid chromatography

    International Nuclear Information System (INIS)

    Lebre, Daniel Temponi

    2000-01-01

    Determination of low concentrations of pesticides in surface and ground waters requires high sensitivity analytical techniques. Solid-Phase Extraction (SPE) has been successfully employed to pre concentrate and extract pesticides compounds from water samples. High Performance Liquid Chromatography (HPLC) coupled with UV/Vis detector was used to separate and quantify the extracted compounds. In this work, samples of surface waters with known concentrations of herbicides (atrazine, simazine and trifluralin) and insecticides (aldicarb, carbofuran and carbaryl) were extracted by using SPE off-line technique. The compounds were separated and quantified by reverse phase HPLC with UV detection at 220 ηm. The extraction efficiency was compared between two columns filled with different materials: C 18 -bonded silica phase (500 mg) and copolymer styrenedivynilbenzene resin (250 mg). The results were evaluated as the percent recovery of compounds obtained using different solvents at different concentrations. The results showed that recovery of the analytes greater than 80 % were obtained in SPE columns filled with C 18 bonded silica phase with 6 mL of acetonitrile. Once the optimum conditions were chosen for simulate water samples, the method was validated through analytical and statistical procedures and applied for surface waters. The suitability of the method was verified for the studied compounds showing good sensitivity, i. e., concentrations within the range of 0.4 to 4.0 μgL -1 of pesticides could be quantified attending the limits proposed by official regulations. (author)

  5. PHARMACEUTICAL AND BIOMEDICAL APPLICATIONS OF AFFINITY CHROMATOGRAPHY: RECENT TRENDS AND DEVELOPMENTS

    Science.gov (United States)

    Hage, David S.; Anguizola, Jeanethe A.; Bi, Cong; Li, Rong; Matsuda, Ryan; Papastavros, Efthimia; Pfaunmiller, Erika; Vargas, John; Zheng, Xiwei

    2012-01-01

    Affinity chromatography is a separation technique that has become increasingly important in work with biological samples and pharmaceutical agents. This method is based on the use of a biologically-related agent as a stationary phase to selectively retain analytes or to study biological interactions. This review discusses the basic principles behind affinity chromatography and examines recent developments that have occurred in the use of this method for biomedical and pharmaceutical analysis. Techniques based on traditional affinity supports are discussed, but an emphasis is placed on methods in which affinity columns are used as part of HPLC systems or in combination with other analytical methods. General formats for affinity chromatography that are considered include step elution schemes, weak affinity chromatography, affinity extraction and affinity depletion. Specific separation techniques that are examined include lectin affinity chromatography, boronate affinity chromatography, immunoaffinity chromatography, and immobilized metal ion affinity chromatography. Approaches for the study of biological interactions by affinity chromatography are also presented, such as the measurement of equilibrium constants, rate constants, or competition and displacement effects. In addition, related developments in the use of immobilized enzyme reactors, molecularly imprinted polymers, dye ligands and aptamers are briefly considered. PMID:22305083

  6. DEVELOPMENT OF METHOD 535 FOR THE DETERMINATION OF CHLOROACETANILIDE AND OTHER ACETAMIDE HERBICIDE DEGRADATES IN DRINKING WATER BY SOLID PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY

    Science.gov (United States)

    EPA Method 535 has been developed in order to provide a method for the analysis of "Alachlor ESA and other acetanilide degradation products" which are listed on U.S. EPA's 1998 Drinking Water Contaminant Candidate List. Method 535 uses solid phase extraction with a nonporous gr...

  7. Development of an analytical method for the determination of histamine in fish by liquid chromatography of high performance in reverse phase

    International Nuclear Information System (INIS)

    Valverde Chavarria, Juan Carlos; Barquero Quiros, Mirian

    2004-01-01

    The histamine is a biogenic amine able to promote allergic intoxications in sensitive persons. For this reason is necessary to have a method of analysis with sensitivity, precision and accuracy able to quantify lower amounts than actual FDA Normative sets. A reverse phase chromatographic method was developed. To identify and quantify histamine through automatic generation of histamine derivative of OPA, using an ultraviolet detector, performance parameters of developed method were adequate to quantification of histamine amount lower than FDA Normative. (Author) [es

  8. Ultrahigh-performance liquid chromatography electrospray ionization Q-Orbitrap mass spectrometry for the analysis of 451 pesticide residues in fruits and vegetables: method development and validation.

    Science.gov (United States)

    Wang, Jian; Chow, Willis; Chang, James; Wong, Jon W

    2014-10-22

    This paper presents an application of ultrahigh-performance liquid chromatography electrospray ionization quadrupole Orbitrap high-resolution mass spectrometry (UHPLC/ESI Q-Orbitrap MS) for the determination of 451 pesticide residues in fruits and vegetables. Pesticides were extracted from samples using the QuEChERS (quick, easy, cheap, effective, rugged, and safe) procedure. UHPLC/ESI Q-Orbitrap MS in full MS scan mode acquired full MS data for quantification, and UHPLC/ESI Q-Orbitrap Full MS/dd-MS(2) (i.e., data-dependent scan mode) obtained product ion spectra for identification. UHPLC/ESI Q-Orbitrap MS quantification was achieved using matrix-matched standard calibration curves along with the use of isotopically labeled standards or a chemical analogue as internal standards to achieve optimal method accuracy. The method performance characteristics include overall recovery, intermediate precision, and measurement uncertainty evaluated according to a nested experimental design. For the 10 matrices studied, 94.5% of the pesticides in fruits and 90.7% in vegetables had recoveries between 81 and 110%; 99.3% of the pesticides in fruits and 99.1% of the pesticides in vegetables had an intermediate precision of ≤20%; and 97.8% of the pesticides in fruits and 96.4% of the pesticides in vegetables showed measurement uncertainty of ≤50%. Overall, the UHPLC/ESI Q-Orbitrap MS demonstrated acceptable performance for the quantification of pesticide residues in fruits and vegetables. The UHPLC/ESI Q-Orbitrap Full MS/dd-MS(2) along with library matching showed great potential for identification and is being investigated further for routine practice.

  9. Develop of analytic method for the determination of vitamin D3 in multivitaminics and minerals using chromatography it liquidates of high efficiency in normal phase with ultraviolet detection

    International Nuclear Information System (INIS)

    Solis Barrantes, J. A.

    1999-01-01

    The good chromatography conditions settled down for the determination vitamin D 3 in multivitaminic samples by means of the analytic technique of chromatography it liquidates of high efficiency (HPLC) in normal phase, with ultraviolet detection to 265 nm. The best conditions in the proposed methodology settled down and the variables of analytic acting were validated, for the analytic quantification of vitamin D 3 in International units. The applicability of the methodology was demonstrated in the vitamin determination D 3 in multivitaminis samples in pill form [es

  10. Determination of maduramicin in feedingstuffs and premixtures by liquid chromatography : development, validation and interlaboratory study

    NARCIS (Netherlands)

    Jong, de J.; Stoisser, B.; Wagner, K.; Tomassen, M.J.H.; Driessen, J.J.M.; Hofman, P.; Putzka, H.A.

    2004-01-01

    A reversed-phase liquid chromatography method for determination of maduramicin in feedingstuffs and premixtures was developed, validated, and interlaboratory studied. The extraction solvent was methanol. Maduramicin was detected at 520 nm after postcolumn derivatization with vanillin. Recovery was

  11. Development of multi-residue method for the determination of pesticides in cereal matrices by isotopic dilution associated to liquid chromatography coupled to tandem mass spectrometry after pressurized liquid extraction

    International Nuclear Information System (INIS)

    El Mrabet, Khadija

    2008-01-01

    Pesticides are nowadays considered as toxic for human health. The maximal residues levels authorized in water and foodstuff are more and more strict. Therefore, selective analytical techniques are necessary for their identification and their quantification. The aim of this thesis was to develop a multi-residue method for the determination of pesticides by isotopic dilution associated to liquid chromatography (LC) coupled with tandem mass spectrometry (MS"2) after pressurized liquid extraction. In a first step, an analysis method of phenyl-ureas and triazines in groundwater by isotopic dilution associated to LC/MS"2 after solid phase extraction has been developed. The method has been validated and evaluated by participating to an inter-laboratory study. Concerning cereals, an extraction method of pesticides associated to an analysis by LC/MS"2 has been developed for thirty-eight pesticides representative of twenty-six chemicals families and fourteen labeled compounds in wheat. The analysis has been carried out in reversed phase chromatography. Separation and detection conditions have been optimized. A global analytical protocol consisting of a pressurized liquid extraction step using acetonitrile at 100 deg. C and at 100 bars and followed by purification step of the resulting extract on a polymeric sorbent was developed. The developed method enables to extract thirty-eight pesticides and fourteen labeled compounds from wheat with recovery yield about 85% (RSD =4%, n=3). Moreover, the results show that the application of isotopic dilution can be complex. Although some improvements need to be added regarding experimentation of aged matrices or contaminated samples, the potential of the method has been demonstrated. (author) [fr

  12. Development of anion-exchange/reversed-phase high performance liquid chromatography-inductively coupled plasma-mass spectrometry methods for the speciation of bio-available iodine and bromine from edible seaweed.

    Science.gov (United States)

    Romarís-Hortas, Vanessa; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio

    2012-05-04

    Anion exchange high performance liquid chromatography hyphenated with inductively coupled plasma-mass spectrometry has been novelly applied to assess inorganic (iodide and iodate) and organic (3-iodotyrosine - MIT, and 3,5-diiodotyrosine - DIT) iodine species in a single chromatographic run. The optimized operating conditions (Dionex IonPac AS7, gradient elution with 175 mM ammonium nitrate plus 15% (v/v) methanol, pH 3.8, as a mobile phase and flow rates within the 0.5-1.5 mL min(-1) range) have also been used to perform inorganic bromine speciation analysis (bromide and bromate). The developed method has been applied for determining the bio-available contents of iodine and bromine species in dialyzates from edible seaweed. Reverse phase high performance liquid chromatography (Zorbax Eclipse XDB-C8, gradient elution with 0.2% (m/m) acetic acid, and 0.2% (m/m) acetic acid in methanol, as mobile phases, and a constant flow rate of 0.75 mL min(-1)) also hyphenated with inductively coupled plasma-mass spectrometry was used to confirm the presence of organic iodine species (MIT and DIT) in the dialyzates. The verification of the presence of iodinated amino acids (MIT and DIT) in the extracts was also performed by reverse phase high performance liquid chromatography-electrospray ionization-mass spectrometry (LTQ Orbitrap). The developed methods have provided good repeatability (RSD values lower than 10% for both anion exchange and reverse phase separations) and analytical recoveries within the 90-105% range for all cases. The in vitro bio-availability method consisted of a simulated gastric and an intestinal digestion/dialysis (10 kDa molecular weight cut-off - MWCO) two-stage procedure. Iodide and MIT were the main bio-available species quantified, whereas bromide was the major bromine species found in the extracts. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Development and validation of a comprehensive two-dimensional gas chromatography-mass spectrometry method for the analysis of phytosterol oxidation products in human plasma

    NARCIS (Netherlands)

    Menéndez-Carreño, M.; Steenbergen, H.; Janssen, H.-G.

    2012-01-01

    Phytosterol oxidation products (POPs) have been suggested to exert adverse biological effects similar to, although less severe than, their cholesterol counterparts. For that reason, their analysis in human plasma is highly relevant. Comprehensive two-dimensional gas chromatography (GC×GC) coupled

  14. Development and optimization of ultra-high performance supercritical fluid chromatography mass spectrometry method for high-throughput determination of tocopherols and tocotrienols in human serum

    Czech Academy of Sciences Publication Activity Database

    Pilařová, V.; Gottvald, T.; Svoboda, P.; Novák, Ondřej; Benešová, K.; Běláková, S.; Nováková, L.

    2016-01-01

    Roč. 934, AUG 31 (2016), s. 252-265 ISSN 0003-2670 R&D Projects: GA MŠk(CZ) LO1204 Institutional support: RVO:61389030 Keywords : Ultra-high performance supercritical fluid chromatography * Mass spectrometry * Liquid liquid extraction Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 4.950, year: 2016

  15. Validated High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, rapid and sensitive high performance liquid ... response, tailing factor and resolution of six replicate injections was < 3 %. ... Cefadroxil monohydrate, Human plasma, Pharmacokinetics Bioequivalence ... Drug-free plasma was obtained from the local .... Influence of probenicid on the renal.

  16. Development and validation of a simple high-performance liquid chromatography analytical method for simultaneous determination of phytosterols, cholesterol and squalene in parenteral lipid emulsions.

    Science.gov (United States)

    Novak, Ana; Gutiérrez-Zamora, Mercè; Domenech, Lluís; Suñé-Negre, Josep M; Miñarro, Montserrat; García-Montoya, Encarna; Llop, Josep M; Ticó, Josep R; Pérez-Lozano, Pilar

    2018-02-01

    A simple analytical method for simultaneous determination of phytosterols, cholesterol and squalene in lipid emulsions was developed owing to increased interest in their clinical effects. Method development was based on commonly used stationary (C 18 , C 8 and phenyl) and mobile phases (mixtures of acetonitrile, methanol and water) under isocratic conditions. Differences in stationary phases resulted in peak overlapping or coelution of different peaks. The best separation of all analyzed compounds was achieved on Zorbax Eclipse XDB C 8 (150 × 4.6 mm, 5 μm; Agilent) and ACN-H 2 O-MeOH, 80:19.5:0.5 (v/v/v). In order to achieve a shorter time of analysis, the method was further optimized and gradient separation was established. The optimized analytical method was validated and tested for routine use in lipid emulsion analyses. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Intelligent automation of high-performance liquid chromatography method development by means of a real-time knowledge-based approach.

    Science.gov (United States)

    I, Ting-Po; Smith, Randy; Guhan, Sam; Taksen, Ken; Vavra, Mark; Myers, Douglas; Hearn, Milton T W

    2002-09-27

    We describe the development, attributes and capabilities of a novel type of artificial intelligence system, called LabExpert, for automation of HPLC method development. Unlike other computerised method development systems, LabExpert operates in real-time, using an artificial intelligence system and design engine to provide experimental decision outcomes relevant to the optimisation of complex separations as well as the control of the instrumentation, column selection, mobile phase choice and other experimental parameters. LabExpert manages every input parameter to a HPLC data station and evaluates each output parameter of the HPLC data station in real-time as part of its decision process. Based on a combination of inherent and user-defined evaluation criteria, the artificial intelligence system programs use a reasoning process, applying chromatographic principles and acquired experimental observations to iteratively provide a regime for a priori development of an acceptable HPLC separation method. Because remote monitoring and control are also functions of LabExpert, the system allows full-time utilisation of analytical instrumentation and associated laboratory resources. Based on our experience with LabExpert with a wide range of analyte mixtures, this artificial intelligence system consistently identified in a similar or faster time-frame preferred sets of analytical conditions that are equal in resolution, efficiency and throughput to those empirically determined by highly experienced chromatographic scientists. An illustrative example, demonstrating the potential of LabExpert in the process of method development of drug substances, is provided.

  18. Banned antibacterial growth promoters in animal feed: Collaborative trial on the liquid chromatography-tandem mass spectrometry method developed in the feedstuffs-radius project

    NARCIS (Netherlands)

    Poucke, C.V.; Dumoulin, F.; Yakkundi, S.; Situ, C.; Elliott, C.T.; Grutters, E.M.; Verheijen, R.; Schilt, R.; Eriksson, S.; Peteghem, C.V.

    2006-01-01

    A chemical confirmation method for the identification and quantification of five banned antibacterial growth promoters (AGPs) in animal feed was developed and in-house validated as part of the European Feedstuffs-RADIUS project [1]. To complete the validation process a collaborative trial was

  19. Development and validation of a high-performance liquid chromatography method for the quantification of talazoparib in rat plasma: Application to plasma protein binding studies.

    Science.gov (United States)

    Hidau, Mahendra Kumar; Kolluru, Srikanth; Palakurthi, Srinath

    2018-02-01

    A sensitive and selective RP-HPLC method has been developed and validated for the quantification of a highly potent poly ADP ribose polymerase inhibitor talazoparib (TZP) in rat plasma. Chromatographic separation was performed with isocratic elution method. Absorbance for TZP was measured with a UV detector (SPD-20A UV-vis) at a λ max of 227 nm. Protein precipitation was used to extract the drug from plasma samples using methanol-acetonitrile (65:35) as the precipitating solvent. The method proved to be sensitive and reproducible over a 100-2000 ng/mL linearity range with a lower limit of quantification (LLQC) of 100 ng/mL. TZP recovery was found to be >85%. Following analytical method development and validation, it was successfully employed to determine the plasma protein binding of TZP. TZP has a high level of protein binding in rat plasma (95.76 ± 0.38%) as determined by dialysis method. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Development and validation of a rapid ultra-high performance liquid chromatography method for the assay of benzalkonium chloride using a quality-by-design approach.

    Science.gov (United States)

    Mallik, Rangan; Raman, Srividya; Liang, Xiaoli; Grobin, Adam W; Choudhury, Dilip

    2015-09-25

    A rapid robust reversed-phase UHPLC method has been developed for the analysis of total benzalkonium chloride in preserved drug formulation. A systematic Quality-by-Design (QbD) method development approach using commercial, off the shelf software (Fusion AE(®)) has been used to optimize the column, mobile phases, gradient time, and other HPLC conditions. Total benzalkonium chloride analysis involves simple sample preparation. The method uses gradient elution from an ACE Excel 2 C18-AR column (50mm×2.1mm, 2.0μm particle size), ammonium phosphate buffer (pH 3.3; 10mM) as aqueous mobile phase and methanol/acetonitrile (85/15, v/v) as the organic mobile phase with UV detection at 214nm. Using these conditions, major homologs of the benzalkonium chloride (C12 and C14) have been separated in less than 2.0min. The validation results confirmed that the method is precise, accurate and linear at concentrations ranging from 0.025mg/mL to 0.075mg/mL for total benzalkonium chloride. The recoveries ranged from 99% to 103% at concentrations from 0.025mg/mL to 0.075mg/mL for total benzalkonium chloride. The validation results also confirmed the robustness of the method as predicted by Fusion AE(®). Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Development and validation of stability indicating method for the quantitative determination of venlafaxine hydrochloride in extended release formulation using high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Jaspreet Kaur

    2010-01-01

    Full Text Available Objective : Venlafaxine,hydrochloride is a structurally novel phenethyl bicyclic antidepressant, and is usually categorized as a serotonin-norepinephrine reuptake inhibitor (SNRI but it has been referred to as a serotonin-norepinephrine-dopamine reuptake inhibitor. It inhibits the reuptake of dopamine. Venlafaxine HCL is widely prescribed in the form of sustained release formulations. In the current article we are reporting the development and validation of a fast and simple stability indicating, isocratic high performance liquid chromatographic (HPLC method for the determination of venlafaxine hydrochloride in sustained release formulations. Materials and Methods : The quantitative determination of venlafaxine hydrochloride was performed on a Kromasil C18 analytical column (250 x 4.6 mm i.d., 5 μm particle size with 0.01 M phosphate buffer (pH 4.5: methanol (40: 60 as a mobile phase, at a flow rate of 1.0 ml/min. For HPLC methods, UV detection was made at 225 nm. Results : During method validation, parameters such as precision, linearity, accuracy, stability, limit of quantification and detection and specificity were evaluated, which remained within acceptable limits. Conclusions : The method has been successfully applied for the quantification and dissolution profiling of Venlafaxine HCL in sustained release formulation. The method presents a simple and reliable solution for the routine quantitative analysis of Venlafaxine HCL.

  2. Technical note: development and validation of a method using ultra performance liquid chromatography coupled with tandem mass spectrometry for determination of vitamin B12 concentrations in milk and dairy products.

    Science.gov (United States)

    Zironi, E; Gazzotti, T; Barbarossa, A; Devicienti, C; Scardilli, M; Pagliuca, G

    2013-05-01

    A method using ultra performance liquid chromatography coupled with tandem mass spectrometry was developed to measure cobalamins in naturally enriched raw milk and to evaluate their fate during thermal treatments and along the process of cheese making. After addition of methotrexate as internal standard, samples were submitted to heat treatment in the presence of cyanide, which converts all the less-stable cobalamins into cyanocobalamin; then, purification was performed by a solid-phase extraction step. Reverse-phase ultra performance liquid chromatography separation coupled with tandem mass spectrometry provided a fast and reliable determination. Mass spectrometric analysis was carried out in multiple reaction monitoring mode. The monitored transitions were m/z 678.36 → 147.10 and 678.36 → 359.30 for vitamin B12 and m/z 455.22 → 175.13 and 455.22 → 308.22 for methotrexate (internal standard). The limit of quantification was 2 ng/g. The method showed good linearity from 2 to 20 ng/g (R(2) ≥ 0.98) and intra- and interday precisions were always less than 19%. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Development and Single-Laboratory Validation of a Liquid Chromatography Tandem Mass Spectrometry Method for Quantitation of Tetrodotoxin in Mussels and Oysters.

    Science.gov (United States)

    Turner, Andrew D; Boundy, Michael J; Rapkova, Monika Dhanji

    2017-09-01

    In recent years, evidence has grown for the presence of tetrodotoxin (TTX) in bivalve mollusks, leading to the potential for consumers of contaminated products to be affected by Tetrodotoxin Shellfish Poisoning (TSP). A single-laboratory validation was conducted for the hydrophilic interaction LC (HILIC) tandem MS (MS/MS) analysis of TTX in common mussels and Pacific oysters-the bivalve species that have been found to contain TTXs in the United Kingdom in recent years. The method consists of a single-step dispersive extraction in 1% acetic acid, followed by a carbon SPE cleanup step before dilution and instrumental analysis. The full method was developed as a rapid tool for the quantitation of TTX, as well as for the associated analogs 4-epi-TTX; 5,6,11-trideoxy TTX; 11-nor TTX-6-ol; 5-deoxy TTX; and 4,9-anhydro TTX. The method can also be run as the acquisition of TTX together with paralytic shellfish toxins. Results demonstrated acceptable method performance characteristics for specificity, linearity, recovery, ruggedness, repeatability, matrix variability, and within-laboratory reproducibility for the analysis of TTX. The LOD and LOQ were fit-for-purpose in comparison to the current action limit for TTX enforced in The Netherlands. In addition, aspects of method performance (LOD, LOQ, and within-laboratory reproducibility) were found to be satisfactory for three other TTX analogs (11-nor TTX-6-ol, 5-deoxy TTX, and 4,9-anhydro TTX). The method was found to be practical and suitable for use in regulatory testing, providing rapid turnaround of sample analysis. Plans currently underway on a full collaborative study to validate a HILIC-MS/MS method for paralytic shellfish poisoning toxins will be extended to include TTX in order to generate international acceptance, ultimately for use as an alternative official control testing method should regulatory controls be adopted.

  4. Development and validation of a method for the determination of regulated fragrance allergens by High-Performance Liquid Chromatography and Parallel Factor Analysis 2.

    Science.gov (United States)

    Pérez-Outeiral, Jessica; Elcoroaristizabal, Saioa; Amigo, Jose Manuel; Vidal, Maider

    2017-12-01

    This work presents the development and validation of a multivariate method for quantitation of 6 potentially allergenic substances (PAS) related to fragrances by ultrasound-assisted emulsification microextraction coupled with HPLC-DAD and PARAFAC2 in the presence of other 18 PAS. The objective is the extension of a previously proposed univariate method to be able to determine the 24 PAS currently considered as allergens. The suitability of the multivariate approach for the qualitative and quantitative analysis of the analytes is discussed through datasets of increasing complexity, comprising the assessment and validation of the method performance. PARAFAC2 showed to adequately model the data facing up different instrumental and chemical issues, such as co-elution profiles, overlapping spectra, unknown interfering compounds, retention time shifts and baseline drifts. Satisfactory quality parameters of the model performance were obtained (R 2 ≥0.94), as well as meaningful chromatographic and spectral profiles (r≥0.97). Moreover, low errors of prediction in external validation standards (below 15% in most cases) as well as acceptable quantification errors in real spiked samples (recoveries from 82 to 119%) confirmed the suitability of PARAFAC2 for resolution and quantification of the PAS. The combination of the previously proposed univariate approach, for the well-resolved peaks, with the developed multivariate method allows the determination of the 24 regulated PAS. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Determination of C-glucosidic ellagitannins in Lythri salicariaeherba by ultra-high performance liquid chromatography coupled with charged aerosol detector: method development and validation.

    Science.gov (United States)

    Granica, Sebastian; Piwowarski, Jakub P; Kiss, Anna K

    2014-01-01

    Lythri salicariaeherba is a pharmacopoeial plant material used by patients in the form of infusions in the treatment of acute diarrhoea. According to its pharmacopoeial monograph it is standardised for total tannin content, which should be not less than 5.0% using pyrogallol as a standard. Previous studies have shown that aqueous extracts from Lythri herba contain mainly ellagitannins among which vescalagin, castalagin and salicarinins A and B are dominating constituents. To develop and validate an efficient UHPLC coupled with a charged aerosol detector (CAD) method for quantification of four major ellagitannins in Lythri salicariaeherba and in one commercial preparation. Extraction conditions of ellagitannins from plant material were optimised. The relative response factors for vescalagin, castalagin and salicarinins A and B using gallic acid as an external standard were determined for the CAD detector. Then, a UHPLC method for quantification of ellagitannins was developed and validated. Four major ellagitannins were quantified in four samples of Lythri herba and in one commercial preparation. The sum of ellagitannins for each sample was determined, which varied from 30.66 to 48.80 mg/g of raw material and 16.57 mg per capsule for the preparation investigated. The first validated UHPLC/CAD UHPLC-CAD method for quantification of four major ellagitannins was developed. The universality of the CAD response was evaluated and it is shown that although all compounds analysed have similar structures their CAD response differs significantly. Copyright © 2013 John Wiley & Sons, Ltd.

  6. Purification of flavonoids from licorice using an off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method.

    Science.gov (United States)

    Fan, Yunpeng; Fu, Yanhui; Fu, Qing; Cai, Jianfeng; Xin, Huaxia; Dai, Mei; Jin, Yu

    2016-07-01

    An orthogonal (71.9%) off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method coupled with effective sample pretreatment was developed for separation and purification of flavonoids from licorice. Most of the nonflavonoids were firstly removed using a self-made Click TE-Cys (60 μm) solid-phase extraction. In the first dimension, an industrial grade preparative chromatography was employed to purify the crude flavonoids. Click TE-Cys (10 μm) was selected as the stationary phase that provided an excellent separation with high reproducibility. Ethyl acetate/ethanol was selected as the mobile phase owing to their excellent solubility for flavonoids. Flavonoids co-eluted in the first dimension were selected for further purification using reversed-phase liquid chromatography. Multiple compounds could be isolated from one normal-phase fraction and some compounds with bad resolution in one-dimensional liquid chromatography could be prepared in this two-dimensional system owing to the orthogonal separation. Moreover, this two-dimensional liquid chromatography method was beneficial for the preparation of relatively trace flavonoid compounds, which were enriched in the first dimension and further purified in the second dimension. Totally, 24 flavonoid compounds with high purity were obtained. The results demonstrated that the off-line two-dimensional liquid chromatography method was effective for the preparative separation and purification of flavonoids from licorice. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Development and validation of a liquid chromatography method for the simultaneous determination of eight water-soluble vitamins in multivitamin formulations and human urine.

    Science.gov (United States)

    Patil, Suyog S; Srivastava, Ashwini K

    2013-01-01

    A simple, precise, and rapid RPLC method has been developed without incorporation of any ion-pair reagent for the simultaneous determination of vitamin C (C) and seven B-complex vitamins, viz, thiamine hydrochloride (B1), pyridoxine hydrochloride (B6), nicotinamide (B3), cyanocobalamine (B12), folic acid, riboflavin (B2), and 4-aminobenzoic acid (Bx). Separations were achieved within 12.0 min at 30 degrees C by gradient elution on an RP C18 column using a mobile phase consisting of a mixture of 15 mM ammonium formate buffer and 0.1% triethylamine adjusted to pH 4.0 with formic acid and acetonitrile. Simultaneous UV detection was performed at 275 and 360 nm. The method was validated for system suitability, LOD, LOQ, linearity, precision, accuracy, specificity, and robustness in accordance with International Conference on Harmonization guidelines. The developed method was implemented successfully for determination of the aforementioned vitamins in pharmaceutical formulations containing an individual vitamin, in their multivitamin combinations, and in human urine samples. The calibration curves for all analytes showed good linearity, with coefficients of correlation higher than 0.9998. Accuracy, intraday repeatability (n = 6), and interday repeatability (n = 7) were found to be satisfactory.

  8. Bioanalytical method development and validation for the determination of glycine in human cerebrospinal fluid by ion-pair reversed-phase liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Jiang, Jian; James, Christopher A; Wong, Philip

    2016-09-05

    A LC-MS/MS method has been developed and validated for the determination of glycine in human cerebrospinal fluid (CSF). The validated method used artificial cerebrospinal fluid as a surrogate matrix for calibration standards. The calibration curve range for the assay was 100-10,000ng/mL and (13)C2, (15)N-glycine was used as an internal standard (IS). Pre-validation experiments were performed to demonstrate parallelism with surrogate matrix and standard addition methods. The mean endogenous glycine concentration in a pooled human CSF determined on three days by using artificial CSF as a surrogate matrix and the method of standard addition was found to be 748±30.6 and 768±18.1ng/mL, respectively. A percentage difference of -2.6% indicated that artificial CSF could be used as a surrogate calibration matrix for the determination of glycine in human CSF. Quality control (QC) samples, except the lower limit of quantitation (LLOQ) QC and low QC samples, were prepared by spiking glycine into aliquots of pooled human CSF sample. The low QC sample was prepared from a separate pooled human CSF sample containing low endogenous glycine concentrations, while the LLOQ QC sample was prepared in artificial CSF. Standard addition was used extensively to evaluate matrix effects during validation. The validated method was used to determine the endogenous glycine concentrations in human CSF samples. Incurred sample reanalysis demonstrated reproducibility of the method. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Development of a stability-indicating high performance liquid chromatography method for assay of erythromycin ethylsuccinate in powder for oral suspension dosage form

    Directory of Open Access Journals (Sweden)

    Fahimeh Kamarei

    2014-12-01

    Full Text Available In this study an effective method was developed to assay erythromycin ethylsuccinate for an oral suspension dosage form. The chromatographic separation was achieved on an X-Terra™ C18 analytical column. A mixture of acetonitrile–ammonium dihydrogen phosphate buffer (0.025 mol L-1 (60:40, V/V (pH 7.0 was used as the mobile phase, effluent flow rate monitored at 1.0 mL min−1, and UV detection at 205 nm. In forced degradation studies, the effects of acid, base, oxidation, UV light and temperature were investigated showing no interference in the peak of drug. The proposed method was validated in terms of specificity, linearity, robustness, precision and accuracy. The method was linear at concentrations ranging from 400 to 600 μg mL−1, precise (intra- and inter-day relative standard deviations <0.65, accurate (mean recovery; 99.5%. The impurities and degradation products of erythromycin ethylsuccinate were selectively determined with good resolution in both the raw material and the final suspension forms. The method could be useful for both routine analytical and quality control assays of erythromycin ethylsuccinate in commercial powder for an oral suspension dosage form and it could be a very powerful tool to investigate the chemical stability of erythromycin ethylsuccinate.

  10. Development and Validation of a Multiresidue Method for the Determination of Pesticides in Dry Samples (Rice and Wheat Flour) Using Liquid Chromatography/Triple Quadrupole Tandem Mass Spectrometry.

    Science.gov (United States)

    Grande-Martínez, Ángel; Arrebola, Francisco Javier; Moreno, Laura Díaz; Vidal, José Luis Martínez; Frenich, Antonia Garrido

    2015-01-01

    A rapid and sensitive multiresidue method was developed and validated for the determination of around 100 pesticides in dry samples (rice and wheat flour) by ultra-performance LC coupled to a triple quadrupole mass analyzer working in tandem mode (UPLC/QqQ-MS/MS). The sample preparation step was optimized for both matrixes. Pesticides were extracted from rice samples using aqueous ethyl acetate, while aqueous acetonitrile extraction [modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method] was used for wheat flour matrixes. In both cases the extracts were then cleaned up by dispersive solid phase extraction with MgSO4 and primary secondary amine+C18 sorbents. A further cleanup step with Florisil was necessary to remove fat in wheat flour. The method was validated at two concentration levels (3.6 and 40 μg/kg for most compounds), obtaining recoveries ranging from 70 to 120%, intraday and interday precision values≤20% expressed as RSDs, and expanded uncertainty values≤50%. The LOQ values ranged between 3.6 and 20 μg/kg, although it was set at 3.6 μg/kg for the majority of the pesticides. The method was applied to the analysis of 20 real samples, and no pesticides were detected.

  11. Development and validation of a high performance liquid chromatography quantification method of levo-tetrahydropalmatine and its metabolites in plasma and brain tissues: application to a pharmacokinetic study.

    Science.gov (United States)

    Abdallah, Inas A; Huang, Peng; Liu, Jing; Lee, David Y; Liu-Chen, Lee-Yuan; Hassan, Hazem E

    2017-04-01

    Levo-tetrahydropalmatine (l-THP) is an alkaloid isolated from Chinese medicinal herbs of the Corydalis and Stephania genera. It has been used in China for more than 40 years mainly as an analgesic with sedative/hypnotic effects. Despite its extensive use, its metabolism has not been quantitatively studied, nor there a sensitive reliable bioanalytical method for its quantification simultaneously with its metabolites. As such, the objective of this study was to develop and validate a sensitive and selective HPLC method for simultaneous quantification of l-THP and its desmethyl metabolites l-corydalmine (l-CD) and l-corypalmine (l-CP) in rat plasma and brain tissues. Rat plasma and brain samples were processed by liquid-liquid extraction using ethyl acetate. Chromatographic separation was achieved on a reversed-phase Symmetry® C 18 column (4.6 × 150 mm, 5 μm) at 25°C. The mobile phase consisted of acetonitrile-methanol-10 mm ammonium phosphate (pH 3) (10:30:60, v/v) and was used at a flow rate of 0.8 mL/min. The column eluent was monitored at excitation and emission wavelengths of 230 and 315 nm, respectively. The calibration curves were linear over the concentration range of 1-10,000 ng/mL. The intra- and interday reproducibility studies demonstrated accuracy and precision within the acceptance criteria of bioanalytical guidelines. The validated HPLC method was successfully applied to analyze samples from a pharmacokinetic study of l-THP in rats. Taken together, the developed method can be applied for bioanalysis of l-THP and its metabolites in rodents and potentially can be transferred for bioanalysis of human samples. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Develop and validation of an analytic method for the histamine determination in fish, using chromatography liquidates of high efficiency in reverse phase with ultraviolet detection

    International Nuclear Information System (INIS)

    Valverde Chavarria, J. C.

    1997-01-01

    There were determined and optimized the reaction and conditions analysis, for the derivation of the histamine with the reagent of or-ftalaldehido (OPA), it was proven that it is possible to quantify the one derived formed at 333nm. The good conditions crhomatografics settled down for the determination of the histamine in fish by means of the analytic technique of chromatography it liquidates of high efficiency (HPLC) in reverse phase, using the derivatizacion in precolumn of the histamine with the reagent of OPA, with ultraviolet detection at 333nm. The conditions of the proposed methodology were optimized and the variables of analytic acting were validated, for the analytic quantification of the histamine in the mg g-1 environment. The applicability of the methodology was demonstrated in the histamine determination in samples of fresh fish [es

  13. Development of a confirmatory method for detecting recombinant bovine somatotropin in plasma by immunomagnetic precipitation followed by ultra-high performance liquid chromatography coupled to tandem mass spectrometry.

    Science.gov (United States)

    Robert, Christelle; Huet, Anne-Catherine; Suárez-Pantaleón, Célia; Brasseur, Amaury; Delahaut, Philippe; Gillard, Nathalie

    2017-11-01

    Recombinant bovine somatotropin (rbST), a synthetic growth hormone, is used to stimulate growth and enhance milk production in dairy cows. Both its use and the sale of dairy products from treated animals are prohibited in the European Union, as well as in Australia, Canada, Japan, and New Zealand, but authorised in several countries (e.g. Brazil, USA). Screening methods involve detecting anti-rbST antibodies (biomarkers) in treated cows. Confirmatory methods are required to prove rbST abuse. The major challenges in determining rbST are its potentially low levels, its high similarity to native bST, and matrix interferences. To overcome these obstacles, we have developed a method involving immunomagnetic precipitation followed by UHPLC-MS/MS for rbST detection. Briefly, protein G magnetic beads pre-coated with an in-house produced monoclonal antibody were added to plasma. Incubation at room temperature allowed rbST present in the sample to bind to the magnetic beads. After that, magnetic beads were isolated by centrifugation and thoroughly washed (PBS, PBS + 0.2% Tween 20). Finally, rbST was released by alkalinisation and the samples were trypsin digested prior to UHPLC-MS/MS analysis in the MRM mode. Validation was done in accordance with European Commission Decision 2002/657/CE. Matrix-matched calibration with internal standards was used. The decision limit (CCα) reached with this approach was 0.11 µg l -1 .

  14. Establishment of analysis method for methane detection by gas chromatography

    Science.gov (United States)

    Liu, Xinyuan; Yang, Jie; Ye, Tianyi; Han, Zeyu

    2018-02-01

    The study focused on the establishment of analysis method for methane determination by gas chromatography. Methane was detected by hydrogen flame ionization detector, and the quantitative relationship was determined by working curve of y=2041.2x+2187 with correlation coefficient of 0.9979. The relative standard deviation of 2.60-6.33% and the recovery rate of 96.36%∼105.89% were obtained during the parallel determination of standard gas. This method was not quite suitable for biogas content analysis because methane content in biogas would be over the measurement range in this method.

  15. Development of a supercritical fluid extraction-gas chromatography-mass spectrometry method for the identification of highly polar compounds in secondary organic aerosols formed from biogenic hydrocarbons in smog chamber experiments.

    Science.gov (United States)

    Chiappini, L; Perraudin, E; Durand-Jolibois, R; Doussin, J F

    2006-11-01

    A new one-step method for the analysis of highly polar components of secondary organic aerosols (SOA) has been developed. This method should lead to a better understanding of SOA formation and evolution since it enables the compounds responsible for SOA formation to be identified. Since it is based on supercritical fluid extraction coupled to gas chromatography-mass spectrometry, it minimizes the analysis time and significantly enhances sensitivity, which makes it suitable for trace-level compounds, which are constituents of SOA. One of the key features of this method is the in situ derivatisation step: an online silylation allowing the measurement of highly polar, polyfunctional compounds, which is a prerequisite for the elucidation of chemical mechanisms. This paper presents the development of this analytical method and highlights its ability to address this major atmospheric issue through the analysis of SOA formed from the ozonolysis of a biogenic hydrocarbon (sabinene). Ozonolysis of sabinene was performed in a 6 m3 Teflon chamber. The aerosol components were derivatised in situ. More than thirty products, such as sabinaketone, sabinic acid and other multifunctional compounds including dicarboxylic acids and oxoacids, were measured. Nine of them were identified and quantified. The sensitivity and the linearity (0.91method were both good and detection limits ranged from 1.2 to 6.4 ng for the investigated compounds.

  16. Development of a supercritical fluid extraction-gas chromatography-mass spectrometry method for the identification of highly polar compounds in secondary organic aerosols formed from biogenic hydrocarbons in smog chamber experiments

    Energy Technology Data Exchange (ETDEWEB)

    Chiappini, L.; Perraudin, E.; Durand-Jolibois, R.; Doussin, J.F. [Universites Paris, Laboratoire Interuniversitaire des Systemes Atmospheriques, UMR CNRS 7583, Creteil (France)

    2006-11-15

    A new one-step method for the analysis of highly polar components of secondary organic aerosols (SOA) has been developed. This method should lead to a better understanding of SOA formation and evolution since it enables the compounds responsible for SOA formation to be identified. Since it is based on supercritical fluid extraction coupled to gas chromatography-mass spectrometry, it minimizes the analysis time and significantly enhances sensitivity, which makes it suitable for trace-level compounds, which are constituents of SOA. One of the key features of this method is the in situ derivatisation step: an online silylation allowing the measurement of highly polar, polyfunctional compounds, which is a prerequisite for the elucidation of chemical mechanisms. This paper presents the development of this analytical method and highlights its ability to address this major atmospheric issue through the analysis of SOA formed from the ozonolysis of a biogenic hydrocarbon (sabinene). Ozonolysis of sabinene was performed in a 6 m{sup 3} Teflon chamber. The aerosol components were derivatised in situ. More than thirty products, such as sabinaketone, sabinic acid and other multifunctional compounds including dicarboxylic acids and oxoacids, were measured. Nine of them were identified and quantified. The sensitivity and the linearity (0.91 < R < 0.98) of the method were both good and detection limits ranged from 1.2 to 6.4 ng for the investigated compounds. (orig.)

  17. Milrinone therapeutic drug monitoring in a pediatric population: Development and validation of a quantitative liquid chromatography-tandem mass spectrometry method.

    Science.gov (United States)

    Raizman, Joshua E; Taylor, Katherine; Parshuram, Christopher; Colantonio, David A

    2017-05-01

    Milrinone is a potent selective phosphodiesterase type III inhibitor which stimulates myocardial function and improves myocardial relaxation. Although therapeutic monitoring is crucial to maintain therapeutic outcome, little data is available. A proof-of-principle study has been initiated in our institution to evaluate the clinical impact of optimizing milrinone dosing through therapeutic drug monitoring (TDM) in children following cardiac surgery. We developed a robust LC-MS/MS method to quantify milrinone in serum from pediatric patients in real-time. A liquid-liquid extraction procedure was used to prepare samples for analysis prior to measurement by LC-MS/MS. Performance characteristics, such as linearity, limit of quantitation (LOQ) and precision, were assessed. Patient samples were acquired post-surgery and analyzed to determine the concentration-time profile of the drug as well as to track turn-around-times. Within day precision was milrinone levels were either sub-therapeutic or in the toxic range, highlighting the importance for milrinone TDM. This simplified and quick method proved to be analytically robust and able to provide therapeutic monitoring of milrinone in real-time in patients post-cardiac surgery. Copyright © 2017. Published by Elsevier B.V.

  18. Development and validation of a multi-residue method for the detection of a wide range of hormonal anabolic compounds in hair using gas chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Rambaud, Lauriane; Monteau, Fabrice; Deceuninck, Yoann; Bichon, Emmanuelle; Andre, Francois; Le Bizec, Bruno

    2007-01-01

    The monitoring of anabolic steroid residues in hair is undoubtedly one of the most efficient strategies to demonstrate the long-term administration of these molecules in meat production animals. A multi-residue sample preparation procedure was developed and validated for 28 steroids. A 100 mg hair sample was grinded into powder and extracted at 50 deg. C with methanol. After acidic hydrolysis and extraction with ethyl acetate, phenolsteroids, such as estrogens, resorcyclic acid lactones and stilbens in one hand, are separated from androgens and progestagens in the other hand. Solid phase extractions were performed before applying a specific derivatisation for each compound sub-group. Detection and identification were achieved using gas chromatography-tandem mass spectrometry with acquisition in the selected reaction monitoring mode after electron ionisation. The method was validated according to the 2002/657/EC guideline. Decision limits (CCα) for main steroids were in the 0.1-10 μg kg -1 range

  19. Development and Validation of Liquid Chromatography- Mass ...

    African Journals Online (AJOL)

    HP

    Method: A novel liquid chromatography–tandem mass spectrometry method for the quantitative determination of naproxen in human K2-EDTA plasma in negative ion mode was employed ..... Practice and Applications of Bio-analytical Method.

  20. Evaluation between ultrahigh pressure liquid chromatography and high-performance liquid chromatography analytical methods for characterizing natural dyestuffs.

    Science.gov (United States)

    Serrano, Ana; van Bommel, Maarten; Hallett, Jessica

    2013-11-29

    An evaluation was undertaken of ultrahigh pressure liquid chromatography (UHPLC) in comparison to high-performance liquid chromatography (HPLC) for characterizing natural dyes in cultural heritage objects. A new UHPLC method was optimized by testing several analytical parameters adapted from prior UHPLC studies developed in diverse fields of research. Different gradient elution programs were tested on seven UHPLC columns with different dimensions and stationary phase compositions by applying several mobile phases, flow rates, temperatures, and runtimes. The UHPLC method successfully provided more improved data than that achieved by the HPLC method. Indeed, even though carminic acid has shown circa 146% higher resolution with HPLC, UHPLC resulted in an increase of 41-61% resolution and a decrease of 91-422% limit of detection, depending on the dye compound. The optimized method was subsequently assigned to analyse 59 natural reference materials, in which 85 different components were ascribed with different physicochemical properties, in order to create a spectral database for future characterization of dyes in cultural heritage objects. The majority of these reference samples could be successfully distinguished with one single method through the examination of these compounds' retention times and their spectra acquired with a photodiode array detector. These results demonstrate that UHPLC analyses are extremely valuable for the acquisition of more precise chromatographic information concerning natural dyes with complex mixtures of different and/or closely related physicochemical properties, essential for distinguishing similar species of plants and animals used to colour cultural heritage objects. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Simultaneous determination of seven flavonoids in Epimedium by liquid chromatography-tandem mass spectrometry method

    Institute of Scientific and Technical Information of China (English)

    Cai Sheng Wu; Bao Lin Guo; Yu Xin Sheng; Jin Lan Zhang

    2008-01-01

    In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoids, namely epimedin A, epimedin B, epimedin C, icariin, sagittatoside B, 2"-0-rhamnosyl icariside II, and baohuoside I in Epimedium from different sources.

  2. Development and validation of a confirmatory method for the determination of 12 non steroidal anti-inflammatory drugs in milk using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Dubreil-Chéneau, Estelle; Pirotais, Yvette; Bessiral, Mélaine; Roudaut, Brigitte; Verdon, Eric

    2011-09-16

    A rapid and reliable LC-MS/MS method for the simultaneous confirmation of twelve non steroidal anti-inflammatory drugs (NSAIDs) in bovine milk was developed and fully validated in accordance with the European Commission Decision 2002/657/EC. The validation scheme was built in accordance with the MRLs or target analytical levels (EU-CRL recommended concentrations and detection capabilities) of the analytes, except for diclofenac for which the lower level of validation achieved was 0.5 μg kg(-1) whereas its MRL is 0.1 μg kg(-1). The NSAIDs investigated were as follows: phenylbutazone (PBZ), oxyphenylbutazone (OPB), naproxen (NP), mefenamic acid (MF), vedaprofen (VDP), flunixin (FLU), 5-hydroxyflunixin (FLU-OH), tolfenamic acid (TLF), meloxicam (MLX), diclofenac (DC), carprofen (CPF) and ketoprofen (KTP). Several extraction procedures had been investigated during the development phase. Finally, the best results were obtained with a procedure using only methanol as the extraction solvent, with an evaporation step included and no further purification. Chromatographic separation was achieved on a C18 analytical column and the run was split in 2 segments. Matrix effects were also investigated. Data acquisition implemented for the confirmatory purpose was performed by monitoring 2 MRM transitions per analyte under the negative electrospray mode. Mean relative recoveries ranged from 94.7% to 110.0%, with their coefficients of variation lying between 2.9% and 14.7%. Analytical limits expressed in terms of decision limits (CCα) were evaluated between 0.69 μg kg(-1) (FLU) and 27.54 μg kg(-1) (VDP) for non-MRL compounds, and at 0.10 (DC), 15.37 (MLX), 45.08 (FLU-OH), and 62.96 μg kg(-1) (TLF) for MRL compounds. The validation results proved that the method is suitable for the screening and confirmatory steps as implemented for the French monitoring plan for NSAID residue control in bovine milk. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Airtight miniaturized chromatography: a safer method for radiopharmaceutical quality control

    International Nuclear Information System (INIS)

    Coupal, J.J.; Shih, W.J.; Ryo, U.Y.

    1988-01-01

    Miniaturized chromatography is widely used for quality control of radiopharmaceuticals. Recently, published chromatography procedures have illustrated or described chromatography chambers open to the air in use, suggesting that volatile toxic mobile phases are harmless to people in the vicinity. The authors describe the results of their search for an inexpensive closed chromatography chamber that can be used to derive safely the benefits from conventional miniaturized chromatography

  4. Development and Validation of a Reversed-Phase Liquid Chromatography Method for the Simultaneous Determination of Indole-3-Acetic Acid, Indole-3-Pyruvic Acid, and Abscisic Acid in Barley (Hordeum vulgare L.).

    Science.gov (United States)

    Nakurte, Ilva; Keisa, Anete; Rostoks, Nils

    2012-01-01

    A simple, sensitive, precise, and specific reverse HPLC method was developed and validated for the determination of plant hormones in barley (Hordeum vulgare L.). The method includes extraction in aqueous organic solvent followed by solid-phase extraction, sample evaporation, and reversed-phase HPLC analysis in a general purpose UV-visible (abscisic acid (ABA)) and fluorescence detection (indole-3-acetic acid (IAA) and indole-3-pyruvic acid (IPA)), high-performance liquid chromatography system. The separation was carried out on Zorbax Eclipse XDB C8 column (150  ×  4.6  mm I.D) with a mobile phase composed of methanol and 1% acetic acid (60 : 40 v/v) in isocratic mode at a flow rate of 1 ml min(-1). The detection was monitored at 270 nm (ABA) and at 282 nm (Ex) and 360 nm (Em) (IAA, IPA). The developed method was validated in terms of accuracy, precision, linearity, limit of detection, limit of quantification, and robustness. The determined validation parameters are in the commonly acceptable ranges for that kind of analysis.

  5. Development of a comprehensive screening method for more than 300 organic chemicals in water samples using a combination of solid-phase extraction and liquid chromatography-time-of-flight-mass spectrometry.

    Science.gov (United States)

    Chau, Hong Thi Cam; Kadokami, Kiwao; Ifuku, Tomomi; Yoshida, Yusuke

    2017-12-01

    A comprehensive screening method for 311 organic compounds with a wide range of physicochemical properties (log Pow -2.2-8.53) in water samples was developed by combining solid-phase extraction with liquid chromatography-high-resolution time-of-flight mass spectrometry. Method optimization using 128 pesticides revealed that tandem extraction with styrene-divinylbenzene polymer and activated carbon solid-phase extraction cartridges at pH 7.0 was optimal. The developed screening method was able to extract 190 model compounds with average recovery of 80.8% and average relative standard deviations (RSD) of 13.5% from spiked reagent water at 0.20 μg L -1 , and 87.1% recovery and 10.8% RSD at 0.05 μg L -1 . Spike-recovery testing (0.20 μg L -1 ) using real sewage treatment plant effluents resulted in an average recovery and average RSD of 190 model compounds of 77.4 and 13.1%, respectively. The method was applied to the influent and effluent of five sewage treatment plants in Kitakyushu, Japan, with 29 out of 311 analytes being observed at least once. The results showed that this method can screen for a large number of chemicals with a wide range of physicochemical properties quickly and at low operational cost, something that is difficult to achieve using conventional analytical methods. This method will find utility in target screening of hazardous chemicals with a high risk in environmental waters, and for confirming the safety of water after environmental incidents.

  6. Plasma chromatography

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    This book examines the fundamental theory and various applications of ion mobility spectroscopy. Plasma chromatography developed from research on the diffusion and mobility of ions. Topics considered include instrument design and description (e.g., performance, spectral interpretation, sample handling, mass spectrometry), the role of ion mobility in plasma chromatography (e.g., kinetic theory of ion transport), atmospheric pressure ionization (e.g., rate equations), the characterization of isomers by plasma chromatography (e.g., molecular ion characteristics, polynuclear aromatics), plasma chromatography as a gas chromatographic detection method (e.g., qualitative analysis, continuous mobility monitoring, quantitative analysis), the analysis of toxic vapors by plasma chromatography (e.g., plasma chromatograph calibration, instrument control and data processing), the analysis of semiconductor devices and microelectronic packages by plasma chromatography/mass spectroscopy (e.g., analysis of organic surface contaminants, analysis of water in sealed electronic packages), and instrument design and automation (hardware, software)

  7. Development and validation of a high-performance liquid chromatography method for determination of lisinopril in human plasma by magnetic solid-phase extraction and pre-column derivatization.

    Science.gov (United States)

    Rastkari, Noushin; Ahmadkhaniha, Reza

    2018-03-01

    A sensitive, reliable and simple HPLC method was developed for the determination of lisinopril in human plasma. The method consists of extraction and clean-up steps based on magnetic solid-phase extraction and pre-column derivatization with a fluorescent reagent. The mobile phase consisted of a mixture of methanol-sodium dihydrogen phosphate (pH 3.0; 0.005 m; 75:25, v/v). The flow rate was set at 0.7 mL/min. Fluorescence detection was performed at 470nm excitation and 530nm emission wavelengths. Total chromatography run time was 5 min. The average extraction recovery of lisinopril and fluvoxamine (internal standard) was ≥82.8%. The limits of detection and quantification were determined as 1 and 3 ng/mL respectively. The method exhibited a linear calibration line over the concentration range of 3-1000 ng/mL with coefficient of determination (r 2 ) of ≥0.98. The within-run and between-run precisions were satisfactory with values of CV of 1.8-12.8% (accuracy from 99.2 to 94.7%) and 2.4-13.7% (accuracy from 99.5 to 92.2%), respectively. These developments led to considerable improvement in method sensitivity and reliability. The method was validated according to the US Food and Drug Administration guidelines. Therefore, it can be considered as a suitable method for determination of lisinopril in plasma samples. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Development and validation of a quantitative method for the determination of 12 endocannabinoids and related compounds in human plasma using liquid chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Balvers, M.G.J.; Verhoeckx, K.C.M.; Witkamp, R.F.

    2009-01-01

    A sensitive and specific LC¿MS/MS method for the quantification of the endocannabinoids and related structures anandamide, 2-arachidonoyl glycerol, 2-arachidonyl glycerol ether, O-arachidonoyl ethanolamide, dihomo-¿-linolenoyl ethanolamide, docosatetraenoyl ethanolamide, N-arachidonoyl dopamine,

  9. Development and validation of a magnetic solid-phase extraction with high-performance liquid chromatography method for the simultaneous determination of amphetamine and methadone in urine.

    Science.gov (United States)

    Taghvimi, Arezou; Hamishehkar, Hamed; Ebrahimi, Mahmoud

    2016-06-01

    The simultaneous determination of amphetamine and methadone was carried out by magnetic graphene oxide nanoparticles, a magnetic solid-phase extraction adsorbent, as a new sample treatment technique. The main factors (the amounts of sample volume, amount of adsorbent, type and amount of extraction organic solvent, time of extraction and desorption, pH, the ionic strength of extraction medium, and agitation rate) influencing the extraction efficiency were investigated and optimized. Under the optimized conditions, good linearity was observed in the range of 100-1500 ng/mL for amphetamine and 100-1000 ng/mL for methadone. The method was evaluated for determination of AM and methadone in positive urine samples, satisfactory results were obtained, therefore magnetic solid-phase extraction can be applied as a novel method for the determination of drugs of abuse in forensic laboratories. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Development and validation of the first assay method coupling liquid chromatography with chemiluminescence for the simultaneous determination of menadione and its thioether conjugates in rat plasma.

    Science.gov (United States)

    Elgawish, Mohamed Saleh; Shimomai, Chikako; Kishikawa, Naoya; Ohyama, Kaname; Wada, Mitsuhiro; Kuroda, Naotaka

    2013-09-16

    Menadione (2-methyl-1,4-naphthoquinone, MQ), a component of multivitamin drugs with antihemorrhagic, antineoplastic, and antimalarial activity, is frequently used to investigate quinone-induced cytotoxicity. The formation of MQ conjugates with glutathione (GSH) by Michael addition and subsequent biotransformation to yield N-acetyl-l-cysteine conjugates is believed to be an important detoxification process. However, the resulting conjugates, 2-methyl-3-(glutathione-S-yl)-1,4-naphthoquinone (MQ-GS) and 2-methyl-3-(N-acetyl-l-cysteine-S-yl)-1,4-naphthoquinone (MQ-NAC), retain the ability to redox cycle and to arylate cellular nucleophiles. Although the nephrotoxicity and hepatotoxicity of MQ-thiol conjugates have been reported in vitro, methods for their determination in vivo have yet to be published. Herein, a highly sensitive, simple, and selective HPLC-chemiluminescence (HPLC-CL) coupled method is reported, allowing for the first time the simultaneous determination of MQ, MQ-GS, and MQ-NAC in rat plasma after MQ administration. Our method exploits the unique redox characteristics of MQ, MQ-GS, and MQ-NAC to react with dithiothreitol (DTT) to liberate reactive oxygen species (ROS) which are detected by a CL assay using luminol as a CL probe. To verify the proposed mechanism, MQ-GS and MQ-NAC were synthetically prepared. Specimen preparation involved solid-phase extraction on an Oasis HLB cartridge followed by isocratic elution on an ODS column. No interference from endogenous substances was detected. Linearity was observed in the range of 5-120 nM for MQ-GS and MQ-NAC and 10-240 nM for MQ, with detection limits (S/N of 3) of 1.4, 0.8, and 128 fmol for MQ-GS, MQ-NAC, and MQ, respectively. The application of our method reported here is the first to extensively study the stability and reversibility of thiol-quinones.

  11. Development of a Liquid Chromatography High Resolution Mass Spectrometry (LC-HRMS) Method for the Quantitation of Viral Envelope Glycoprotein in Ebola Virus-Like Particle Vaccine Preparations

    Science.gov (United States)

    2016-09-05

    distribution is unlimited. UNCLASSIFIED Background: 92 Ebola is an extremely pathogenic virus that causes hemorrhagic fever and can result in 93... animals . 155 156 Materials and Methods: 157 Generation and Characterization of eVLPs. 158 TR-16-141 DISTRIBUTION STATEMENT A...measuring the optical density (OD) at 280 nm in 186 a spectrophotometer and assuming an extinction coefficient at 1% equal to 10 (under this 187

  12. Method development for the determination of 24S-hydroxycholesterol in human plasma without derivatization by high-performance liquid chromatography with tandem mass spectrometry in atmospheric pressure chemical ionization mode.

    Science.gov (United States)

    Sugimoto, Hiroshi; Kakehi, Masaaki; Satomi, Yoshinori; Kamiguchi, Hidenori; Jinno, Fumihiro

    2015-10-01

    We developed a highly sensitive and specific high-performance liquid chromatography with tandem mass spectrometry method with an atmospheric pressure chemical ionization interface to determine 24S-hydroxycholesterol, a major metabolite of cholesterol formed by cytochrome P450 family 46A1, in human plasma without any derivatization step. Phosphate buffered saline including 1% Tween 80 was used as the surrogate matrix for preparation of calibration curves and quality control samples. The saponification process to convert esterified 24S-hydroxycholesterol to free sterols was optimized, followed by liquid-liquid extraction using hexane. Chromatographic separation of 24S-hydroxycholesterol from other isobaric endogenous oxysterols was successfully achieved with gradient mobile phase comprised of 0.1% propionic acid and acetonitrile using L-column2 ODS (2 μm, 2.1 mm id × 150 mm). This assay was capable of determining 24S-hydroxycholesterol in human plasma (200 μL) ranging from 1 to 100 ng/mL with acceptable intra- and inter-day precision and accuracy. The potential risk of in vitro formation of 24S-hydroxycholesterol by oxidation from endogenous cholesterol in human plasma was found to be negligible. The stability of 24S-hydroxycholesterol in relevant solvents and human plasma was confirmed. This method was successfully applied to quantify the plasma concentrations of 24S-hydroxycholesterol in male and female volunteers. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Development of a new screening method for the detection of antibiotic residues in muscle tissues using liquid chromatography and high resolution mass spectrometry with a LC-LTQ-Orbitrap instrument.

    Science.gov (United States)

    Hurtaud-Pessel, D; Jagadeshwar-Reddy, T; Verdon, E

    2011-10-01

    A liquid chromatography-high resolution mass spectrometry (LC-HRMS) method was developed for screening meat for a wide range of antibiotics used in veterinary medicine. Full-scan mode under high resolution mass spectral conditions using an LTQ-Orbitrap mass spectrometer with resolving power 60,000 full width at half maximum (FWHM) was applied for analysis of the samples. Samples were prepared using two extraction protocols prior to LC-HRMS analysis. The scope of the method focuses on screening the following main families of antibacterial veterinary drugs: penicillins, cephalosporins, sulfonamides, macrolides, tetracyclines, aminoglucosides and quinolones. Compounds were successfully identified in spiked samples from their accurate mass and LC retention times from the acquired full-scan chromatogram. Automated data processing using ToxId software allowed rapid treatment of the data. Analyses of muscle tissues from real samples collected from antibiotic-treated animals was carried out using the above methodology and antibiotic residues were identified unambiguously. Further analysis of the data for real samples allowed the identification of the targeted antibiotic residues but also non-targeted compounds, such as some of their metabolites.

  14. Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method Coupled with Dispersive Solid-Phase Extraction for Simultaneous Quantification of Eight Paralytic Shellfish Poisoning Toxins in Shellfish

    Science.gov (United States)

    Yang, Xianli; Zhou, Lei; Tan, Yanglan; Shi, Xizhi; Zhao, Zhiyong; Nie, Dongxia; Zhou, Changyan; Liu, Hong

    2017-01-01

    In this study, a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for simultaneous determination of eight paralytic shellfish poisoning (PSP) toxins, including saxitoxin (STX), neosaxitoxin (NEO), gonyautoxins (GTX1–4) and the N-sulfo carbamoyl toxins C1 and C2, in sea shellfish. The samples were extracted by acetonitrile/water (80:20, v/v) with 0.1% formic and purified by dispersive solid-phase extraction (dSPE) with C18 silica and acidic alumina. Qualitative and quantitative detection for the target toxins were conducted under the multiple reaction monitoring (MRM) mode by using the positive electrospray ionization (ESI) mode after chromatographic separation on a TSK-gel Amide-80 HILIC column with water and acetonitrile. Matrix-matched calibration was used to compensate for matrix effects. The established method was further validated by determining the linearity (R2 ≥ 0.9900), average recovery (81.52–116.50%), sensitivity (limits of detection (LODs): 0.33–5.52 μg·kg−1; limits of quantitation (LOQs): 1.32–11.29 μg·kg−1) and precision (relative standard deviation (RSD) ≤ 19.10%). The application of this proposed approach to thirty shellfish samples proved its desirable performance and sufficient capability for simultaneous determination of multiclass PSP toxins in sea foods. PMID:28661471

  15. Development of a simple and rapid solid phase microextraction-gas chromatography-triple quadrupole mass spectrometry method for the analysis of dopamine, serotonin and norepinephrine in human urine.

    Science.gov (United States)

    Naccarato, Attilio; Gionfriddo, Emanuela; Sindona, Giovanni; Tagarelli, Antonio

    2014-01-31

    The work aims at developing a simple and rapid method for the quantification of dopamine (DA), serotonin (5-HT) and norepinephrine (NE) in human urine. The urinary levels of these biogenic amines can be correlated with several pathological conditions concerning heart disease, stress, neurological disorders and cancerous tumors. The proposed analytical approach is based on the use of solid phase microextraction (SPME) combined with gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) after a fast derivatization of both aliphatic amino and phenolic moieties by propyl chloroformate. The variables influencing the derivatization reaction were reliably optimized by the multivariate approach of "Experimental design". The optimal conditions were obtained by performing derivatization with 100μL of propyl chloroformate and 100μL of pyridine. The extraction ability of five commercially available SPME fibers was evaluated in univariate mode and the best results were obtained using the polyacrylate fiber. The variables affecting the efficiency of SPME analysis were again optimized by the multivariate approach of "Experimental design" and, in particular, a central composite design (CCD) was applied. The optimal values were extraction in 45min at room temperature, desorption temperature at 300°C, no addition of NaCl. Assay of derivatized analytes was performed by using a gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) system in selected reaction monitoring (SRM) acquisition. An evaluation of all analytical parameters demonstrates that the developed method provides satisfactory results. Indeed, very good linearities were achieved in the tested calibration range with correlation coefficient values of 0.9995, 0.9999 and 0.9997 for DA, 5-HT and NE, respectively. Accuracies and RSDs calculated for between-run and tested at concentrations of 30, 200, and 800μg L(-1) were in the range from 92.8% to 103.0%, and from 0.67 to 4.5%, respectively. Finally

  16. Development of a new microextraction method based on elevated temperature dispersive liquid-liquid microextraction for determination of triazole pesticides residues in honey by gas chromatography-nitrogen phosphorus detection.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Mogaddam, Mohammad Reza Afshar; Ghorbanpour, Houshang

    2014-06-20

    In the present study, a rapid, highly efficient, and reliable sample preparation method named "elevated temperature dispersive liquid-liquid microextraction" followed by gas chromatography-nitrogen-phosphorus detection was developed for the extraction, preconcentration, and determination of five triazole pesticides (penconazole, hexaconazole, diniconazole, tebuconazole, and difenoconazole) in honey samples. In this method the temperature of high-volume aqueous phase was adjusted at an elevated temperature and then a disperser solvent containing an extraction solvent was rapidly injected into the aqueous phase. After cooling to room temperature, the phase separation was accelerated by centrifugation. Various parameters affecting the extraction efficiency such as type and volume of the extraction and disperser solvents, temperature, salt addition, and pH were evaluated. Under the optimum extraction conditions, the method resulted in low limits of detection and quantification within the range 0.05-0.21ngg(-1) in honey (15-70ngL(-1) in solution) and 0.15-1.1ngg(-1) in honey (45-210ngL(-1) in solution), respectively. Enrichment factors and extraction recoveries were in the ranges of 1943-1994 and 97-100%, respectively. The method precision was evaluated at 1.5ngg(-1) of each analyte, and the relative standard deviations were found to be less than 4% for intra-day (n=6) and less than 6% for inter-days. The method was successfully applied to the analysis of honey samples and difenoconazole was determined at ngg(-1) levels. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Development and validation of a multi-residue method for the detection of a wide range of hormonal anabolic compounds in hair using gas chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Rambaud, Lauriane [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France); Monteau, Fabrice [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France); Deceuninck, Yoann [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France); Bichon, Emmanuelle [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France); Andre, Francois [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France); Le Bizec, Bruno [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France)]. E-mail: lebizec@vet-nantes.fr

    2007-03-14

    The monitoring of anabolic steroid residues in hair is undoubtedly one of the most efficient strategies to demonstrate the long-term administration of these molecules in meat production animals. A multi-residue sample preparation procedure was developed and validated for 28 steroids. A 100 mg hair sample was grinded into powder and extracted at 50 deg. C with methanol. After acidic hydrolysis and extraction with ethyl acetate, phenolsteroids, such as estrogens, resorcyclic acid lactones and stilbens in one hand, are separated from androgens and progestagens in the other hand. Solid phase extractions were performed before applying a specific derivatisation for each compound sub-group. Detection and identification were achieved using gas chromatography-tandem mass spectrometry with acquisition in the selected reaction monitoring mode after electron ionisation. The method was validated according to the 2002/657/EC guideline. Decision limits (CC{alpha}) for main steroids were in the 0.1-10 {mu}g kg{sup -1} range.

  18. Development and Validation of a Chromatography Method Using Tandem UV/Charged Aerosol Detector for Simultaneous Determination of Amlodipine Besylate and Olmesartan Medoxomil: Application to Drug-Excipient Compatibility Study

    Directory of Open Access Journals (Sweden)

    Ariadne M. Brondi

    2017-01-01

    Full Text Available A study was carried out to investigate compatibility of amlodipine besylate and olmesartan medoxomil with a variety of pharmaceutical excipients. Both drugs are antihypertensive agents that can be administered alone, in monotherapy, or in pharmaceutical association. The studies were performed using binary and ternary mixtures, and samples were stored for 3 and 6 months at 40°C under 75% relative humidity and dry conditions. For this study, a method based on high-performance liquid chromatography (HPLC was developed and validated for the simultaneous determination of amlodipine besylate and olmesartan medoxomil in samples from pharmaceutical preformulation studies using diode array detector (DAD and charged aerosol detector (CAD. The runtime per sample was 10 min with retention time of 7.926 min and 4.408 min for amlodipine and olmesartan, respectively. The validation was performed according to ICH guidelines. The calibration curve presents linear dynamic range from 12 to 250 μg mL−1 for amlodipine and from 25 to 500 μg mL−1 for olmesartan with coefficient of determination (R2 ≥ 0.9908 while repeatability and reproducibility (expressed as relative standard deviation were lower than 1.0%. The excipients such as corn starch, croscarmellose sodium, magnesium stearate, polyvinyl alcohol, talc, polyvinylpyrrolidone, lactose monohydrate, and polyethylene glycol showed potential incompatibilities after accelerated stability testing.

  19. Development and validation of a simple solid-phase extraction method coupled with liquid chromatography-triple quadrupole tandem mass spectrometry for simultaneous determination of lincomycin, tylosin A and tylosin B in royal jelly.

    Science.gov (United States)

    Zheng, Weijia; Park, Jin-A; Abd El-Aty, A M; Kim, Seong-Kwan; Cho, Sang-Hyun; Choi, Jeong-Min; Warda, Mohamad; Wang, Jing; Shim, Jae-Han; Shin, Ho-Chul

    2018-04-01

    We have developed an analytical method for the determination of lincomycin, tylosin A and tylosin B residues in royal jelly using liquid chromatography-triple quadrupole tandem mass spectrometry analysis. For extraction and purification, we employed 1% trifluoroacetic acid and 0.1 m Na 2 EDTA solutions along with an Oasis HLB cartridge. The target antibiotics were well separated in a Kinetex EVO C 18 reversed-phase analytical column using a combination of 0.1% formate acid in ultrapure water (A) and acetonitrile (B) as the mobile phase. Good linearity was achieved over the tested concentration range (5-50 μg/kg) in matrix-matched standard calibration. The coefficients of determination (R 2 ) were 0.9933, 0.9933 and 0.996, for tylosin A, tylosin B and lincomycin, respectively. Fortified royal jelly spiked with three different concentrations of the tested antibiotics (5, 10 and 20 μg/kg) yielded recoveries in the range 80.94-109.26% with relative standard deviations ≤4%. The proposed method was applied to monitor 11 brand of royal jelly collected from domestic markets and an imported brand from New Zealand; all the samples tested negative for lincomycin, tylosin A and tylosin B residues. In conclusion, 1% trifluoroacetic acid and 0.1 m Na 2 EDTA aqueous solvents combined with solid-phase extraction could effectively complete the sample preparation process for royal jelly before analysis. The developed approach can be applied for a routine analysis of lincomycin, tylosin A and tylosin B residues in royal jelly. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Development, validation and application of a micro-liquid chromatography-tandem mass spectrometry based method for simultaneous quantification of selected protein biomarkers of endothelial dysfunction in murine plasma.

    Science.gov (United States)

    Suraj, Joanna; Kurpińska, Anna; Olkowicz, Mariola; Niedzielska-Andres, Ewa; Smolik, Magdalena; Zakrzewska, Agnieszka; Jasztal, Agnieszka; Sitek, Barbara; Chlopicki, Stefan; Walczak, Maria

    2018-02-05

    The objective of this study was to develop and validate the method based on micro-liquid chromatography-tandem mass spectrometry (microLC/MS-MRM) for simultaneous determination of adiponectin (ADN), von Willebrand factor (vWF), soluble form of vascular cell adhesion molecule 1 (sVCAM-1), soluble form of intercellular adhesion molecule 1 (sICAM-1) and syndecan-1 (SDC-1) in mouse plasma. The calibration range was established from 2.5pmol/mL to 5000pmol/mL for ADN; 5pmol/mL to 5000pmol/mL for vWF; 0.375pmol/mL to 250pmol/mL for sVCAM-1 and sICAM-1; and 0.25pmol/mL to 250pmol/mL for SDC-1. The method was applied to measure the plasma concentration of selected proteins in mice fed high-fat diet (HFD), and revealed the pro-thrombotic status by increased concentration of vWF (1.31±0.17 nmol/mL (Control) vs 1.98±0.09 nmol/mL (HFD), p <0.05) and the dysregulation of adipose tissue metabolism by decreased concentration of ADN (0.62±0.08 nmol/mL (Control) vs 0.37±0.06 nmol/mL (HFD), p <0.05). In conclusion, the microLC/MS-MRM-based method allows for reliable measurements of selected protein biomarkers of endothelial dysfunction in mouse plasma. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Development and validation of a gas chromatography-negative chemical ionization tandem mass spectrometry method for the determination of ethyl glucuronide in hair and its application to forensic toxicology.

    Science.gov (United States)

    Kharbouche, Hicham; Sporkert, Frank; Troxler, Stéphanie; Augsburger, Marc; Mangin, Patrice; Staub, Christian

    2009-08-01

    Ethyl glucuronide (EtG) is a minor and direct metabolite of ethanol. EtG is incorporated into the growing hair allowing retrospective investigation of chronic alcohol abuse. In this study, we report the development and the validation of a method using gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS/MS) for the quantification of EtG in hair. EtG was extracted from about 30 mg of hair by aqueous incubation and purified by solid-phase extraction (SPE) using mixed mode extraction cartridges followed by derivation with perfluoropentanoic anhydride (PFPA). The analysis was performed in the selected reaction monitoring (SRM) mode using the transitions m/z 347-->163 (for the quantification) and m/z 347-->119 (for the identification) for EtG, and m/z 352-->163 for EtG-d(5) used as internal standard. For validation, we prepared quality controls (QC) using hair samples taken post mortem from 2 subjects with a known history of alcoholism. These samples were confirmed by a proficiency test with 7 participating laboratories. The assay linearity of EtG was confirmed over the range from 8.4 to 259.4 pg/mg hair, with a coefficient of determination (r(2)) above 0.999. The limit of detection (LOD) was estimated with 3.0 pg/mg. The lower limit of quantification (LLOQ) of the method was fixed at 8.4 pg/mg. Repeatability and intermediate precision (relative standard deviation, RSD%), tested at 4 QC levels, were less than 13.2%. The analytical method was applied to several hair samples obtained from autopsy cases with a history of alcoholism and/or lesions caused by alcohol. EtG concentrations in hair ranged from 60 to 820 pg/mg hair.

  2. Lipidomic analysis of biological samples: Comparison of liquid chromatography, supercritical fluid chromatography and direct infusion mass spectrometry methods.

    Science.gov (United States)

    Lísa, Miroslav; Cífková, Eva; Khalikova, Maria; Ovčačíková, Magdaléna; Holčapek, Michal

    2017-11-24

    Lipidomic analysis of biological samples in a clinical research represents challenging task for analytical methods given by the large number of samples and their extreme complexity. In this work, we compare direct infusion (DI) and chromatography - mass spectrometry (MS) lipidomic approaches represented by three analytical methods in terms of comprehensiveness, sample throughput, and validation results for the lipidomic analysis of biological samples represented by tumor tissue, surrounding normal tissue, plasma, and erythrocytes of kidney cancer patients. Methods are compared in one laboratory using the identical analytical protocol to ensure comparable conditions. Ultrahigh-performance liquid chromatography/MS (UHPLC/MS) method in hydrophilic interaction liquid chromatography mode and DI-MS method are used for this comparison as the most widely used methods for the lipidomic analysis together with ultrahigh-performance supercritical fluid chromatography/MS (UHPSFC/MS) method showing promising results in metabolomics analyses. The nontargeted analysis of pooled samples is performed using all tested methods and 610 lipid species within 23 lipid classes are identified. DI method provides the most comprehensive results due to identification of some polar lipid classes, which are not identified by UHPLC and UHPSFC methods. On the other hand, UHPSFC method provides an excellent sensitivity for less polar lipid classes and the highest sample throughput within 10min method time. The sample consumption of DI method is 125 times higher than for other methods, while only 40μL of organic solvent is used for one sample analysis compared to 3.5mL and 4.9mL in case of UHPLC and UHPSFC methods, respectively. Methods are validated for the quantitative lipidomic analysis of plasma samples with one internal standard for each lipid class. Results show applicability of all tested methods for the lipidomic analysis of biological samples depending on the analysis requirements

  3. Methods of analysis-Determination of pesticides in sediment using gas chromatography/mass spectrometry

    Science.gov (United States)

    Hladik, Michelle; McWayne, Megan M.

    2012-01-01

    A method for the determination of 119 pesticides in environmental sediment samples is described. The method was developed by the U.S. Geological Survey (USGS) in support of the National Water Quality Assessment (NAWQA) Program. The pesticides included in this method were chosen through prior prioritization. Herbicides, insecticides, and fungicides along with degradates are included in this method and span a variety of chemical classes including, but not limited to, chloroacetanilides, organochlorines, organophosphates, pyrethroids, triazines, and triazoles. Sediment samples are extracted by using an accelerated solvent extraction system (ASE®, and the compounds of interest are separated from co-extracted matrix interferences (including sulfur) by passing the extracts through high performance liquid chromatography (HPLC) with gel-permeation chromatography (GPC) along with the use of either stacked graphitized carbon and alumina solid-phase extraction (SPE) cartridges or packed Florisil®. Chromatographic separation, detection, and quantification of the pesticides from the sediment-sample extracts are done by using gas chromatography with mass spectrometry (GC/MS). Recoveries in test sediment samples fortified at 10 micrograms per kilogram (μg/kg) dry weight ranged from 75 to 102 percent; relative standard deviations ranged from 3 to 13 percent. Method detection limits (MDLs), calculated by using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), ranged from 0.6 to 3.4 μg/kg dry weight.

  4. Development and validation of a multiresidue method for the simultaneous determination of organophosphorus insecticides and their toxic metabolites in sugarcane juice and refined sugar by gas chromatography with flame photometric detection.

    Science.gov (United States)

    Ramasubramanian, Thirumalaiandi; Paramasivam, Mariappan

    2016-06-01

    A multiresidue method has been developed and validated for the simultaneous determination of organophosphorus insecticides and their toxic metabolites in sugarcane juice and refined sugar by gas chromatography with flame photometric detection. Limits of quantification of the method varied between 0.007 and 0.01 μg/g. Ethyl acetate based extraction followed by dispersive solid-phase extraction cleanup with primary secondary amine yielded internationally acceptable recoveries of acephate, chlorpyrifos, dichlorvos, monocrotophos, malathion, malaoxon, phorate, phorate-sulfoxide, phorate-oxon, phorate-sulfone, and quinalphos from selected matrices. The recoveries of target analytes from cane juice were 75.55 ± 0.5-102.57 ± 4.2, 77.45 ± 4.7-103.33 ± 3.3, and 80.55 ± 6.6-105.82 ± 9.8% at 0.01, 0.02, and 0.1 μg/g levels of fortification, respectively. The recoveries from cane sugar were 73.24 ± 3.5-104.47 ± 1.9, 75.23 ± 1.5-116.10 ± 3.7, and 70.75 ± 5.7-110.15 ± 2.7%, respectively at 0.01, 0.02, and 0.1 μg/g levels of fortification. Matrix effect and measurement uncertainty were within the permissible limit (less than 20%) as prescribed for pesticide residue analysis. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Method development for trace and ultratrace analysis

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Method development, that is, selection of a mode of chromatography and the right column and mobile-phase combination for trace and ultratrace analysis, requires several main considerations. The method should be useful for resolving various trace and ultratrace components present in the sample. If the nature of these components is known, the choice of method may be straightforward, that is, a selection can be made from the following modes of HPLC: (1) adsorption chromatography; (2) normal-phase chromatography; (3) reversed-phase chromatography; (4) ion-pair chromatography; (5) ion-exchange chromatography; (6) ion chromatography. Unfortunately, the nature of all of the components is frequently unknown. However, several intelligent judgments can be made on the nature of impurities. This chapter deals with some basic approaches to mobile-phase selection and optimization. More detailed information may be found in basic texts. Techniques for separation of high-molecular-weight compounds (macromolecules) and chiral compounds may be found elsewhere. Mainly compounds with molecular weight lower than 2,000 are discussed here. 123 refs

  6. A simple high performance liquid chromatography method for analyzing paraquat in soil solution samples.

    Science.gov (United States)

    Ouyang, Ying; Mansell, Robert S; Nkedi-Kizza, Peter

    2004-01-01

    A high performance liquid chromatography (HPLC) method with UV detection was developed to analyze paraquat (1,1'-dimethyl-4,4'-dipyridinium dichloride) herbicide content in soil solution samples. The analytical method was compared with the liquid scintillation counting (LSC) method using 14C-paraquat. Agreement obtained between the two methods was reasonable. However, the detection limit for paraquat analysis was 0.5 mg L(-1) by the HPLC method and 0.05 mg L(-1) by the LSC method. The LSC method was, therefore, 10 times more precise than the HPLC method for solution concentrations less than 1 mg L(-1). In spite of the high detection limit, the UC (nonradioactive) HPLC method provides an inexpensive and environmentally safe means for determining paraquat concentration in soil solution compared with the 14C-LSC method.

  7. Liquid chromatography method to determine polyamines in thermosetting polymers

    Energy Technology Data Exchange (ETDEWEB)

    Dopico-Garcia, M.S. [Laboratorio de Quimica - Centro de Investigacions Tecnoloxicas, Universidade da Coruna, Campus de Esteiro s/n, 15403 Ferrol (Spain); Centro Galego do Plastico, A Cabana s/n, 15590 Ferrol (Spain); Lopez-Vilarino, J.M. [Laboratorio de Quimica - Centro de Investigacions Tecnoloxicas, Universidade da Coruna, Campus de Esteiro s/n, 15403 Ferrol (Spain); Fernandez-Martinez, G. [Unidad de Tecnicas Cromatograficas, Servizos de Apoio a Investigacion, Edificio Servizos Centrais de Investigacion, Universidade da Coruna, Campus de Elvina s/n, 15071 A Coruna (Spain); Gonzalez-Rodriguez, M.V., E-mail: victoria@udc.es [Dpto. de Quimica Analitica - E.U. Politecnica, Universidade da Coruna, Avda. 19 de Febrero s/n, 15405 Ferrol (Spain)

    2010-05-14

    A simple, robust and sensitive analytical method to determine three polyamines commonly used as hardeners in epoxy resin systems and in the manufacture of polyurethane is reported. The studied polyamines are: one tetramine, TETA (triethylenetetramine), and two diamines, IPDA (Isophorone diamine) and TCD-diamine (4,7-methano-1H-indene-5,?-dimethanamine, octahydro-). The latter has an incompletely defined structure, and, as far as we know, has not been previously determined by other methods. All three polyamines contain primary amines; TETA also contains secondary amines. The analytical method involves derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate, used for the first time for these compounds, followed by high performance liquid chromatography (HPLC) analysis with a fluorescence (FL) detector ({lambda} excitation 248 nm, {lambda} emision 395 nm). The HPLC-DAD-LTQ Orbitrap MS was used in order to provide structural information about the obtained derivatized compounds. The hybrid linear ion trap LTQ Orbitrap mass spectrometer has been introduced in recent years and provides a high mass accuracy. The structures of the derivatized analytes were identified from the protonated molecular ions [M+H]{sup +} and corresponded to the fully labelled analytes. The following analytical parameters were determined for the method using the HPLC-FL: linearity, precision (2.5-10%), instrumental precision intraday (0.8-1.5%) and interday (2.9-6.3%), and detection limits (0.02-0.14 mg L{sup -1}). The stability of stock solutions and derivatized compounds was also investigated. The method was applied to determine the amine free content in epoxy resin dust collected in workplaces.

  8. Liquid chromatography method to determine polyamines in thermosetting polymers.

    Science.gov (United States)

    Dopico-García, M S; López-Vilariño, J M; Fernández-Martínez, G; González-Rodríguez, M V

    2010-05-14

    A simple, robust and sensitive analytical method to determine three polyamines commonly used as hardeners in epoxy resin systems and in the manufacture of polyurethane is reported. The studied polyamines are: one tetramine, TETA (triethylenetetramine), and two diamines, IPDA (Isophorone diamine) and TCD-diamine (4,7-methano-1H-indene-5,?-dimethanamine, octahydro-). The latter has an incompletely defined structure, and, as far as we know, has not been previously determined by other methods. All three polyamines contain primary amines; TETA also contains secondary amines. The analytical method involves derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate, used for the first time for these compounds, followed by high performance liquid chromatography (HPLC) analysis with a fluorescence (FL) detector (lambda excitation 248nm, lambda emision 395nm). The HPLC-DAD-LTQ Orbitrap MS was used in order to provide structural information about the obtained derivatized compounds. The hybrid linear ion trap LTQ Orbitrap mass spectrometer has been introduced in recent years and provides a high mass accuracy. The structures of the derivatized analytes were identified from the protonated molecular ions [M+H](+) and corresponded to the fully labelled analytes. The following analytical parameters were determined for the method using the HPLC-FL: linearity, precision (2.5-10%), instrumental precision intraday (0.8-1.5%) and interday (2.9-6.3%), and detection limits (0.02-0.14mgL(-1)). The stability of stock solutions and derivatized compounds was also investigated. The method was applied to determine the amine free content in epoxy resin dust collected in workplaces. Copyright 2010 Elsevier B.V. All rights reserved.

  9. Liquid chromatography method to determine polyamines in thermosetting polymers

    International Nuclear Information System (INIS)

    Dopico-Garcia, M.S.; Lopez-Vilarino, J.M.; Fernandez-Martinez, G.; Gonzalez-Rodriguez, M.V.

    2010-01-01

    A simple, robust and sensitive analytical method to determine three polyamines commonly used as hardeners in epoxy resin systems and in the manufacture of polyurethane is reported. The studied polyamines are: one tetramine, TETA (triethylenetetramine), and two diamines, IPDA (Isophorone diamine) and TCD-diamine (4,7-methano-1H-indene-5,?-dimethanamine, octahydro-). The latter has an incompletely defined structure, and, as far as we know, has not been previously determined by other methods. All three polyamines contain primary amines; TETA also contains secondary amines. The analytical method involves derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate, used for the first time for these compounds, followed by high performance liquid chromatography (HPLC) analysis with a fluorescence (FL) detector (λ excitation 248 nm, λ emision 395 nm). The HPLC-DAD-LTQ Orbitrap MS was used in order to provide structural information about the obtained derivatized compounds. The hybrid linear ion trap LTQ Orbitrap mass spectrometer has been introduced in recent years and provides a high mass accuracy. The structures of the derivatized analytes were identified from the protonated molecular ions [M+H] + and corresponded to the fully labelled analytes. The following analytical parameters were determined for the method using the HPLC-FL: linearity, precision (2.5-10%), instrumental precision intraday (0.8-1.5%) and interday (2.9-6.3%), and detection limits (0.02-0.14 mg L -1 ). The stability of stock solutions and derivatized compounds was also investigated. The method was applied to determine the amine free content in epoxy resin dust collected in workplaces.

  10. Chromatography methods and chemometrics for determination of milk fat adulterants

    Science.gov (United States)

    Trbović, D.; Petronijević, R.; Đorđević, V.

    2017-09-01

    Milk and milk-based products are among the leading food categories according to reported cases of food adulteration. Although many authentication problems exist in all areas of the food industry, adequate control methods are required to evaluate the authenticity of milk and milk products in the dairy industry. Moreover, gas chromatography (GC) analysis of triacylglycerols (TAGs) or fatty acid (FA) profiles of milk fat (MF) in combination with multivariate statistical data processing have been used to detect adulterations of milk and dairy products with foreign fats. The adulteration of milk and butter is a major issue for the dairy industry. The major adulterants of MF are vegetable oils (soybean, sunflower, groundnut, coconut, palm and peanut oil) and animal fat (cow tallow and pork lard). Multivariate analysis enables adulterated MF to be distinguished from authentic MF, while taking into account many analytical factors. Various multivariate analysis methods have been proposed to quantitatively detect levels of adulterant non-MFs, with multiple linear regression (MLR) seemingly the most suitable. There is a need for increased use of chemometric data analyses to detect adulterated MF in foods and for their expanded use in routine quality assurance testing.

  11. Possibilities and limitations of the kinetic plot method in supercritical fluid chromatography.

    Science.gov (United States)

    De Pauw, Ruben; Desmet, Gert; Broeckhoven, Ken

    2013-08-30

    Although supercritical fluid chromatography (SFC) is becoming a technique of increasing importance in the field of analytical chromatography, methods to compare the performance of SFC-columns and separations in an unbiased way are not fully developed. The present study uses mathematical models to investigate the possibilities and limitations of the kinetic plot method in SFC as this easily allows to investigate a wide range of operating pressures, retention and mobile phase conditions. The variable column length (L) kinetic plot method was further investigated in this work. Since the pressure history is identical for each measurement, this method gives the true kinetic performance limit in SFC. The deviations of the traditional way of measuring the performance as a function of flow rate (fixed back pressure and column length) and the isopycnic method with respect to this variable column length method were investigated under a wide range of operational conditions. It is found that using the variable L method, extrapolations towards other pressure drops are not valid in SFC (deviation of ∼15% for extrapolation from 50 to 200bar pressure drop). The isopycnic method provides the best prediction but its use is limited when operating closer towards critical point conditions. When an organic modifier is used, the predictions are improved for both methods with respect to the variable L method (e.g. deviations decreases from 20% to 2% when 20mol% of methanol is added). Copyright © 2013 Elsevier B.V. All rights reserved.

  12. A high pressure liquid chromatography method for separation of prolactin forms.

    Science.gov (United States)

    Bell, Damon A; Hoad, Kirsten; Leong, Lillian; Bakar, Juwaini Abu; Sheehan, Paul; Vasikaran, Samuel D

    2012-05-01

    Prolactin has multiple forms and macroprolactin, which is thought not to be bioavailable, can cause a raised serum prolactin concentration. Gel filtration chromatography (GFC) is currently the gold standard method for separating macroprolactin, but is labour-intensive. Polyethylene glycol (PEG) precipitation is suitable for routine use but may not always be accurate. We developed a high pressure liquid chromatography (HPLC) assay for macroprolactin measurement. Chromatography was carried out using an Agilent Zorbax GF-250 (9.4 × 250 mm, 4 μm) size exclusion column and 50 mmol/L Tris buffer with 0.15 mmol/L NaCl at pH 7.2 as mobile phase, with a flow rate of 1 mL/min. Serum or plasma was diluted 1:1 with mobile phase and filtered and 100 μL injected. Fractions of 155 μL were collected for prolactin measurement and elution profile plotted. The area under the curve of each prolactin peak was calculated to quantify each prolactin form, and compared with GFC. Clear separation of monomeric-, big- and macroprolactin forms was achieved. Quantification was comparable to GFC and precision was acceptable. Total time from injection to collection of the final fraction was 16 min. We have developed an HPLC method for quantification of macroprolactin, which is rapid and easy to perform and therefore can be used for routine measurement.

  13. Determination of methylmercury and estimation of total mercury in seafood using high performance liquid chromatography (HPLC) and inductively coupled plasma-mass spectrometry (ICP-MS): Method development and validation

    Energy Technology Data Exchange (ETDEWEB)

    Hight, Susan C. [Elemental Research Branch, Center for Food Safety and Applied Nutrition, US Food and Drug Administration, 5100 Paint Branch Parkway, College Park, MD 20740-3835 (United States)]. E-mail: susan.hight@fda.gov; Cheng, John [Elemental Research Branch, Center for Food Safety and Applied Nutrition, US Food and Drug Administration, 5100 Paint Branch Parkway, College Park, MD 20740-3835 (United States)]. E-mail: john.cheng@fda.gov

    2006-05-17

    A method was developed for determination of methylmercury and estimation of total mercury in seafood. Mercury (Hg) compounds were extracted from 0.5 g edible seafood or 0.2 g lyophilized reference material by adding 50 ml aqueous 1% w/v L-cysteine.HCl.H{sub 2}O and heating 120 min at 60 deg. C in glass vials. Hg compounds in 50 {mu}l of filtered extract were separated by reversed-phase high performance liquid chromatography using a C-18 column and aqueous 0.1% w/v L-cysteine.HCl.H{sub 2}O + 0.1% w/v L-cysteine mobile phase at room temperature and were detected by inductively coupled plasma-mass spectrometry at mass-to-charge ratio 202. Total Hg was calculated as the mathematical sum of methyl and inorganic Hg determined in extracts. For seafoods containing 0.055-2.78 mg kg{sup -1} methylmercury and 0.014-0.137 mg kg{sup -1} inorganic Hg, precision of analyses was {<=}5% relative standard deviation (R.S.D.) for methylmercury and {<=}9% R.S.D. for inorganic Hg. Recovery of added analyte was 94% for methylmercury and 98% for inorganic Hg. Methyl and total Hg results for reference materials agreed with certified values. Limits of quantitation were 0.007 mg kg{sup -1} methylmercury and 0.005 mg kg{sup -1} inorganic Hg in edible seafood and 0.017 mg kg{sup -1} methylmercury and 0.012 mg kg{sup -1} inorganic Hg in lyophilized reference materials. Evaluation of analyte stability demonstrated that L-cysteine both stabilized and de-alkylated methylmercury, depending on holding time and cysteine concentration. Polypropylene adversely affected methylmercury stability. Total Hg results determined by this method were equivalent to results determined independently by cold vapour-atomic absorption spectrometry. Methylmercury was the predominant form of Hg in finfish. Ratios of methylmercury/total Hg determined by this method were 93-98% for finfish and 38-48% for mollusks.

  14. A method for fast determination of psoralens in oral solutions of phytomedicines using liquid chromatography.

    Science.gov (United States)

    Pires, Adriana Elias; Honda, Neli Kiko; Cardoso, Cláudia Andréa Lima

    2004-10-29

    A method for sample preparation and analysis by high performance liquid chromatography with UV detection (HPLC-UV) has been developed for routine analysis of psoralen and bergapten, photosensitizing compounds, in oral solutions of phytomedicines employed in Brazil for some illnesses. The linearity, accuracy, the inter- and intra-day precision of the procedure were evaluated. Calibration curves for psoralen and bergapten were linear in the range of 1.0-600.0 microg ml(-1) and 1.0-400.0 microg ml(-1) respectively. The recoveries of the psoralens in the oral solutions analysed were 94.43-99.97%. The percentage coefficient of variation (CV) of the quantitative analysis of the psoralens in the products analysis was within 5%. In inter-equipment study was employed gas chromatography-flame ionization (CG-FID) detection.

  15. Applications of extraction chromatography in the development of radionuclide generator systems for nuclear medicine

    International Nuclear Information System (INIS)

    Dietz, M.L.; Horwitz, E.P.

    2000-01-01

    Numerous methods have been described for the separation and purification of radionuclides for application in diagnostic and therapeutic nuclear medicine, among them ion exchange, solvent extraction, and various forms of chromatography. Although extraction chromatography has previously been shown to provide a means of performing a number of separations of potential use in radionuclide generator systems, the application of the technique to generator development has thus far been limited. Recent work directed at improved methods for the determination of radionuclides in biological and environmental samples has led to the development of a series of novel extraction chromatographic resins exhibiting enhanced metal ion retention from strongly acidic media and excellent selectivity, among them materials suitable for the isolation of 212 Bi, 90 Y, and 213 Bi. These resins, along with extraction chromatographic materials employing functionalized supports to improve their physical stability or metal ion retention properties, are shown to offer promise in the development of improved radionuclide generators

  16. Development of an achiral supercritical fluid chromatography method with ultraviolet absorbance and mass spectrometric detection for impurity profiling of drug candidates. Part II. Selection of an orthogonal set of stationary phases.

    Science.gov (United States)

    Lemasson, Elise; Bertin, Sophie; Hennig, Philippe; Boiteux, Hélène; Lesellier, Eric; West, Caroline

    2015-08-21

    Impurity profiling of organic products that are synthesized as possible drug candidates requires complementary analytical methods to ensure that all impurities are identified. Supercritical fluid chromatography (SFC) is a very useful tool to achieve this objective, as an adequate selection of stationary phases can provide orthogonal separations so as to maximize the chances to see all impurities. In this series of papers, we have developed a method for achiral SFC-MS profiling of drug candidates, based on a selection of 160 analytes issued from Servier Research Laboratories. In the first part of this study, focusing on mobile phase selection, a gradient elution with carbon dioxide and methanol comprising 2% water and 20mM ammonium acetate proved to be the best in terms of chromatographic performance, while also providing good MS response [1]. The objective of this second part was the selection of an orthogonal set of ultra-high performance stationary phases, that was carried out in two steps. Firstly, a reduced set of analytes (20) was used to screen 23 columns. The columns selected were all 1.7-2.5μm fully porous or 2.6-2.7μm superficially porous particles, with a variety of stationary phase chemistries. Derringer desirability functions were used to rank the columns according to retention window, column efficiency evaluated with peak width of selected analytes, and the proportion of analytes successfully eluted with good peak shapes. The columns providing the worst performances were thus eliminated and a shorter selection of columns (11) was obtained. Secondly, based on 160 tested analytes, the 11 columns were ranked again. The retention data obtained on these columns were then compared to define a reduced set of the best columns providing the greatest orthogonality, to maximize the chances to see all impurities within a limited number of runs. Two high-performance columns were thus selected: ACQUITY UPC(2) HSS C18 SB and Nucleoshell HILIC. Copyright © 2015

  17. Buffer-Free High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a simple, economical and reproducible high performance liquid chromatographic (HPLC) method for the determination of theophylline in pharmaceutical dosage forms. Method: Caffeine was used as the internal standard and reversed phase C-18 column was used to elute the drug and ...

  18. Determination of Urine Albumin by New Simple High-Performance Liquid Chromatography Method.

    Science.gov (United States)

    Klapkova, Eva; Fortova, Magdalena; Prusa, Richard; Moravcova, Libuse; Kotaska, Karel

    2016-11-01

    A simple high-performance liquid chromatography (HPLC) method was developed for the determination of albumin in patients' urine samples without coeluting proteins and was compared with the immunoturbidimetric determination of albumin. Urine albumin is important biomarker in diabetic patients, but part of it is immuno-nonreactive. Albumin was determined by high-performance liquid chromatography (HPLC), UV detection at 280 nm, Zorbax 300SB-C3 column. Immunoturbidimetric analysis was performed using commercial kit on automatic biochemistry analyzer COBAS INTEGRA ® 400, Roche Diagnostics GmbH, Manheim, Germany. The HLPC method was fully validated. No significant interference with other proteins (transferrin, α-1-acid glycoprotein, α-1-antichymotrypsin, antitrypsin, hemopexin) was found. The results from 301 urine samples were compared with immunochemical determination. We found a statistically significant difference between these methods (P = 0.0001, Mann-Whitney test). New simple HPLC method was developed for the determination of urine albumin without coeluting proteins. Our data indicate that the HPLC method is highly specific and more sensitive than immunoturbidimetry. © 2016 Wiley Periodicals, Inc.

  19. Pre-staining thin layer chromatography method for amino acid ...

    African Journals Online (AJOL)

    Jane

    2010-12-13

    Dec 13, 2010 ... inexpensive and the results obtained were clean and reproducible. However, it is suitable for the high throughput screening of amino acid-producing strains. Key words: Thin layer chromatography, pre-staining, amino acid detection. INTRODUCTION. Several analytical techniques have been often used for.

  20. Development and validation of a liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of tamoxifen, anastrozole, and letrozole in human plasma and its application to a clinical study.

    Science.gov (United States)

    Beer, Beate; Schubert, Birthe; Oberguggenberger, Anne; Meraner, Verena; Hubalek, Michael; Oberacher, Herbert

    2010-10-01

    There is substantial evidence that circulating estrogens promote the proliferation of breast cancer. Consequently, adjuvant hormonal treatment strategies targeting estrogen action have been established. Such hormonal therapies include selective estrogen receptor modulators, such as tamoxifen, which interfere at the estrogen receptors directly, or non-steroidal aromatase inhibitors, such as anastrozole and letrozole, which inhibit estrogen synthesis through blocking the aromatase, a key enzyme of estrogen production. Despite considerable therapeutic success, in several cases, the use of these drugs is limited by side effects that have been described to significantly impair the adherence of patients to endocrine treatment. However, objective data concerning patient adherence and its clinical relevance are limited. One promising approach to check patient-reported adherence is drug monitoring in human plasma. Therefore, a liquid chromatography-tandem mass spectrometry method to determine the plasma concentrations of tamoxifen, anastrozole, and letrozole has been developed and fully validated according to guidelines for clinical and forensic toxicology. The validation criteria evaluated were selectivity, linearity, accuracy and precision, limit of quantification, recovery and matrix effects, sample stability, and carryover. The six-point calibration curves showed linearity over the range of concentrations from 25 to 500 ng/ml for tamoxifen, 5 to 200 ng/ml for anastrozole, and 10 to 300 ng/ml for letrozole. The intra- and inter-day precision and accuracies were always better than 15%. The validated procedure was successfully applied to a clinical study (Patient-Reported Outcomes in Breast Cancer Patients undergoing Endocrine Therapy, PRO-BETh). A major aim of PRO-BETh study is the comprehensive evaluation of adherence to treatment in pre- and post-menopausal women with breast cancer. Plasma samples of 310 breast cancer patients undergoing anti-estrogen therapy were

  1. Efficient methods for isolating five phytochemicals from Gentiana macrophylla using high-performance countercurrent chromatography.

    Science.gov (United States)

    Rho, Taewoong; Jung, Mila; Lee, Min Won; Chin, Young-Won; Yoon, Kee Dong

    2016-12-01

    Efficient high-performance countercurrent chromatography methods were developed to isolate five typical compounds from the extracts of Gentiana macrophylla. n-Butanol-soluble extract of G. macrophylla contained three hydrophilic iridoids, loganic acid (1), swertiamarin (2) and gentiopicroside (3), and a chromene derivative, macrophylloside D (4) which were successfully isolated by flow rate gradient (1.5 mL/min in 0-60 min, 5.0 mL/min in 60-120 min), and consecutive flow rate gradient HPCCC using n-butanol/0.1% aqueous trifluoroacetic acid (1:1, v/v, normal phase mode) system. The yields of 1-4 were 22, 16, 122, and 6 mg, respectively, with purities over 97% in a flow rate gradient high-performance countercurrent chromatography, and consecutive flow rate gradient high-performance countercurrent chromatography gave 1, 2, 3 (54, 41, 348 mg, respectively, purities over 97%) and 4 (13 mg, purity at 95%) from 750 mg of sample. The main compound in methylene chloride soluble extract, 2-methoxyanofinic acid, was successfully separated by n-hexane/ethyl acetate/methanol/water (4:6:4:6, v/v/v/v, flow-rate: 4 mL/min, reversed phase mode) condition. The structures of five isolates were elucidated by 1 H, 13 C NMR and ESI-Q-TOF-MS spectroscopic data which were compared with previously reported values. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Greening Reversed-Phase Liquid Chromatography Methods Using Alternative Solvents for Pharmaceutical Analysis

    Directory of Open Access Journals (Sweden)

    Moussa Yabré

    2018-05-01

    Full Text Available The greening of analytical methods has gained increasing interest in the field of pharmaceutical analysis to reduce environmental impacts and improve the health safety of analysts. Reversed-phase high-performance liquid chromatography (RP-HPLC is the most widely used analytical technique involved in pharmaceutical drug development and manufacturing, such as the quality control of bulk drugs and pharmaceutical formulations, as well as the analysis of drugs in biological samples. However, RP-HPLC methods commonly use large amounts of organic solvents and generate high quantities of waste to be disposed, leading to some issues in terms of ecological impact and operator safety. In this context, greening HPLC methods is becoming highly desirable. One strategy to reduce the impact of hazardous solvents is to replace classically used organic solvents (i.e., acetonitrile and methanol with greener ones. So far, ethanol has been the most often used alternative organic solvent. Others strategies have followed, such as the use of totally aqueous mobile phases, micellar liquid chromatography, and ionic liquids. These approaches have been well developed, as they do not require equipment investments and are rather economical. This review describes and critically discusses the recent advances in greening RP-HPLC methods dedicated to pharmaceutical analysis based on the use of alternative solvents.

  3. A rapid method for the separation and estimation of uranium in geological materials using ion chromatography

    International Nuclear Information System (INIS)

    Prakash, Satya; Bangroo, P.N.

    2013-01-01

    Ion Chromatography is an elegant analytical technique which was primarily developed for the analysis of anionic species and over the years it has been used successfully to analyse various elements in different matrices. In this work the potential of Ion Chromatography has been used for the rapid separation and estimation of uranium in hydrogeochemical and other geological materials

  4. Recent development of ionic liquid stationary phases for liquid chromatography.

    Science.gov (United States)

    Shi, Xianzhe; Qiao, Lizhen; Xu, Guowang

    2015-11-13

    Based on their particular physicochemical characteristics, ionic liquids have been widely applied in many fields of analytical chemistry. Many types of ionic liquids were immobilized on a support like silica or monolith as stationary phases for liquid chromatography. Moreover, different approaches were developed to bond covalently ionic liquids onto the supporting materials. The obtained ionic liquid stationary phases show multi-mode mechanism including hydrophobic, hydrophilic, hydrogen bond, anion exchange, π-π, and dipole-dipole interactions. Therefore, they could be used in different chromatographic modes including ion-exchange, RPLC, NPLC and HILIC to separate various classes of compounds. This review mainly summarizes the immobilized patterns and types of ionic liquid stationary phases, their retention mechanisms and applications in the recent five years. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Development and validation of a spectroscopic method for the ...

    African Journals Online (AJOL)

    Development and validation of a spectroscopic method for the simultaneous analysis of ... advanced analytical methods such as high pressure liquid ..... equipment. DECLARATIONS ... high-performance liquid chromatography. J Chromatogr.

  6. An optimized method for the measurement of acetaldehyde by high-performance liquid chromatography.

    Science.gov (United States)

    Guan, Xiangying; Rubin, Emanuel; Anni, Helen

    2012-03-01

    Acetaldehyde is produced during ethanol metabolism predominantly in the liver by alcohol dehydrogenase and rapidly eliminated by oxidation to acetate via aldehyde dehydrogenase. Assessment of circulating acetaldehyde levels in biological matrices is performed by headspace gas chromatography and reverse phase high-performance liquid chromatography (RP-HPLC). We have developed an optimized method for the measurement of acetaldehyde by RP-HPLC in hepatoma cell culture medium, blood, and plasma. After sample deproteinization, acetaldehyde was derivatized with 2,4-dinitrophenylhydrazine (DNPH). The reaction was optimized for pH, amount of derivatization reagent, time, and temperature. Extraction methods of the acetaldehyde-hydrazone (AcH-DNP) stable derivative and product stability studies were carried out. Acetaldehyde was identified by its retention time in comparison with AcH-DNP standard, using a new chromatography gradient program, and quantitated based on external reference standards and standard addition calibration curves in the presence and absence of ethanol. Derivatization of acetaldehyde was performed at pH 4.0 with an 80-fold molar excess of DNPH. The reaction was completed in 40 minutes at ambient temperature, and the product was stable for 2 days. A clear separation of AcH-DNP from DNPH was obtained with a new 11-minute chromatography program. Acetaldehyde detection was linear up to 80 μM. The recovery of acetaldehyde was >88% in culture media and >78% in plasma. We quantitatively determined the ethanol-derived acetaldehyde in hepatoma cells, rat blood and plasma with a detection limit around 3 μM. The accuracy of the method was volume (70 μl) plasma sampling. An optimized method for the quantitative determination of acetaldehyde in biological systems was developed using derivatization with DNPH, followed by a short RP-HPLC separation of AcH-DNP. The method has an extended linear range, is reproducible and applicable to small-volume sampling of culture

  7. Novel method for measurement of glutathione kinetics in neonates using liquid chromatography coupled to isotope ratio mass spectrometry

    NARCIS (Netherlands)

    Schierbeek, Henk; te Braake, Frans; Godin, Jean-Philippe; Fay, Laurent-Bernard; van Goudoever, Johannes B.

    2007-01-01

    A novel analytical method using liquid chromatography coupled to isotope ratio mass spectrometry (LC/IRMS) was developed for measuring the fractional synthesis rate (FSR) of glutathione (GSH) in neonates after infusion of [1-(13)C]-glycine as a tracer. After transformation of GSH into GSSG, its

  8. Simple, rapid, and sensitive liquid chromatography-fluorescence method for the quantification of tranexamic acid in blood

    NARCIS (Netherlands)

    Huertas-Pérez, José Fernando; Heger, Michal; Dekker, Henk; Krabbe, Hans; Lankelma, Jan; Ariese, Freek

    2007-01-01

    Tranexamic acid (TA) is a synthetic antifibrinolytic agent that is being considered as a candidate adjuvant drug for site-specific pharmaco-laser therapy of port wine stains. For drug utility studies, a high-performance liquid chromatography (HPLC)-fluorescence method was developed for the

  9. High-performance liquid chromatography method with radiochemical detection for measurement of nitric oxide synthase, arginase, and arginine decarboxylase activities

    DEFF Research Database (Denmark)

    Volke, A; Wegener, Gregers; Vasar, E

    2006-01-01

    regulate NOS activity. We aimed to develop a HPLC-based method to measure simultaneously the products of these three enzymes. Traditionally, the separation of amino acids and related compounds with HPLC has been carried out with precolumn derivatization and reverse phase chromatography. We describe here...

  10. Constructing a LabVIEW-Controlled High-Performance Liquid Chromatography (HPLC) System: An Undergraduate Instrumental Methods Exercise

    Science.gov (United States)

    Smith, Eugene T.; Hill, Marc

    2011-01-01

    In this laboratory exercise, students develop a LabVIEW-controlled high-performance liquid chromatography system utilizing a data acquisition device, two pumps, a detector, and fraction collector. The programming experience involves a variety of methods for interface communication, including serial control, analog-to-digital conversion, and…

  11. Application of partition chromatography method for separation and analysis of actinium radionuclides

    International Nuclear Information System (INIS)

    Sinitsina, G.S.; Shestakova, I.A.; Shestakov, B.I.; Plyushcheva, N.A.; Malyshev, N.A.; Belyatskij, A.F.; Tsirlin, V.A.

    1979-01-01

    The method of partition chromatography is considered with the use of different extractants for the extraction of actinium-227, actinium-225 and actinium-228. It is advisable to extract actinium-227 from the irradiated radium with the help of D2FGFK. The use of 2DEGFK allows us to separate actinium-227 from alkaline and alkaline-earth elements. Amines have a higher radiative stability. An express-method has been developed for the identification of actinium-227 with TOA by its intrinsic α-emission in nonequilibrium preparations of irradiated radium-226 of small activity. Actinium-225 is extracted from uranium-233 with due regard for the fact that U, Th, and Ac are extracted differently by TBP from HNO 3 solutions. With the help of the given procedure one can reach the purifying coefficient of 10 4 . Actinium-228 is extracted from the radiummesothorium preparations by a deposition of decay products, including polonium-210 on the iron hydroxyde. Actinium-228 extraction from the mixture of radium radionuclides is performed by the partition chromatography method on D2EGFK. All the procedures for separation of actinium isotopes by the above methods are described

  12. A fast isocratic liquid chromatography method for the quantification of xanthophylls and their stereoisomers.

    Science.gov (United States)

    Nimalaratne, Chamila; Lopes-Lutz, Daise; Schieber, Andreas; Wu, Jianping

    2015-12-01

    A fast isocratic liquid chromatography method was developed for the simultaneous quantification of eight xanthophylls (13-Z-lutein, 13'-Z-lutein, 13-Z-zeaxanthin, all-E-lutein, all-E-zeaxanthin, all-E-canthaxanthin, all-E-β-apo-8'-carotenoic acid ethyl ester and all-E-β-apo-8'-carotenal) within 12 min, compared to 90 min by the conventional high-performance liquid chromatography method. The separation was achieved on a YMC C30 reversed-phase column (100 mm x 2.0 mm; 3 μm) operated at 20°C using a methanol/tert-butyl methyl ether/water solvent system at a flow rate of 0.8 mL/min. The method was successfully applied to quantify lutein and zeaxanthin stereoisomers in egg yolk, raw and cooked spinach, and a dietary supplement. The method can be used for the rapid analysis of xanthophyll isomers in different food products and for quality control purposes. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Use of laminar chromatographic methods for determination of separation conditions in column extraction chromatography

    International Nuclear Information System (INIS)

    Ghersini, G.; Cerrai, E.

    1978-01-01

    Possibilities of using laminar chromatographic methods (paper and thin-layer chromatography) to determine optimal separation conditions in column extraction chromatography are analysed. Most of the given laminar methods are presented as Rf-spectra, i.e. as dependences of Rf found experimentally on eluating solution component concentration. Interrelation between Rf and distribution coefficients of corresponding liquid extraction systems and retention volumes of chromatographic columns is considered. Literature data on extraction paper and thin-layer chromatography of elements with various immovable phases are presented

  14. Fast methods for screening of trichothecenes in fungal cultures using gas chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Kristian Fog; Thrane, Ulf

    2001-01-01

    The paper presents a fast method for trichothecene profiling and chemotaxonomic studies in species of Fusarium, Stachybotrys, Trichoderma and Memnoniella. Micro scale extracted crude Fusarium extracts were derivatised using pentafluoropropionic anhydride and analysed by gas chromatography...

  15. Validation of a confirmatory method for the determination of melamine in egg by gas chromatography-mass spectrometry and ultra-performance liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Xia Xi; Ding Shuangyang; Li Xiaowei; Gong Xiao; Zhang Suxia; Jiang Haiyang; Li Jiancheng; Shen Jianzhong

    2009-01-01

    A sensitive and reliable method was developed and validated for detection and confirmation of melamine in egg based on gas chromatography-mass spectrometry (GC-MS) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Trichloroacetic acid solution was used for sample extraction and precipitation of proteins. The aqueous extracts were subjected to solid-phase extraction by mixed-mode reversed-phase/strong cation-exchange cartridges. Using ultra-performance liquid chromatography and electrospray ionization in the positive ion mode, melamine was determined by LC-MS/MS, which was completed in 5 min for each injection. For the GC-MS analysis, extracted melamine was derivatized with N,O-bis(trimethylsilyl)trifluoracetamide prior to selected ion monitoring detection in electron impact mode. The average recovery of melamine from fortified samples ranged from 85.2% to 103.2%, with coefficients of variation lower than 12%. The limit of detection obtained by GC-MS and UPLC-MS/MS was 10 and 5 μg kg -1 , respectively. This validated method was successfully applied to the determination of melamine in real samples from market.

  16. Q Sepharose micro-column chromatography: A simple screening method for identifying beta thalassemia traits and hemoglobin E carriers.

    Science.gov (United States)

    Wong, Peerapon; Sritippayawan, Suchila; Suwannakhon, Narutchala; Tapprom, Akamon; Deoisares, Rawisut; Sanguansermsri, Torpong

    2016-11-01

    For beta thalassemia control program in pregnancy, mass screening of the carrier state by determination of the hemoglobin (Hb) A 2 and Hb E proportions and mutation analysis is a preferred method for making prenatal diagnoses. Q Sepharose micro-column chromatography, developed for the determination of Hb A 2 and Hb E for screening purposes, was compared with high performance liquid chromatography (HPLC) to ascertain its relative accuracy and reliability. Results using Q Sepharose micro-column chromatography in 350 blood specimens, including 50 samples genetically proven to be beta thalassemia heterozygotes, were compared to HPLC for validation. An additional study was conducted to test a clinical application on a large-scale survey for beta thalassemia in 1581 pregnant women and their spouses. The mean (±SD) Hb A 2 proportions in the normal and genetically proven beta thalassemia heterozygotes were 2.70±0.40% and 6.30±1.23%, respectively, as determined by Q-Sepharose micro-column chromatography, and 2.65±0.31% and 5.37±0.96%, respectively, as determined by HPLC. The mean Hb E proportions in the Hb E heterozygotes were 23.25±4.13% and 24.72±3.5% as determined by Q Sepharose micro-column chromatography and HPLC, respectively. In the large-scale survey for beta thalassemia, 23 at risk couples were detected. Seven affected fetuses were identified by prenatal diagnosis. Q Sepharose micro-column chromatography was found to be reliable, reproducible and well-suited for large-scale surveys. Additionally, by being reusable and convenient, this simple and economical chromatography method may be an alternative means to screen for beta thalassemia and Hb E carriers in the mass population. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. Establishing the analytical procedure for acetate in water by ion chromatography method

    International Nuclear Information System (INIS)

    Nguyen Thi Hong Thinh; Ha Lan Anh; Vo Thi Anh

    2015-01-01

    In recent studies of contamination sources of arsenic, ammonium, iron, organic carbon in groundwater, acetate is measured a lot because it is the main decomposition product of organic compounds from sediment into groundwater. In order to better support for the study of the origin and mobilization mechanism of the pollutants, acetate was studied analysis method in Isotopes Hydrology Laboratory using ion chromatography technique. Project Researchers used Ion Chromatography system - DX-600 including IonPac ICE-AS1 column for separating acetate and conductivity detector CD 25 to quantify acetate in water samples. The study results showed that project team has successfully developed analytical procedures of acetate in water with acetate’s retention time is 12 minutes, limit of detection (LOD) of the method was 0.01 ppm. The accuracy of the method was established by calculating the precision and bias of 10 analysis times of a standard sample at content levels 1 ppm and 8 ppm. The results of the 10 measurements are satisfiable about precision and bias with repeated standard deviation coefficient CVR were 1.3% and 0.2% and the recoveries R were 99.92% and 101.72%. (author)

  18. DETERMINATION OF RUTIN IN LEAVES OF SALIX TRIANDRA USING THE METHOD OF PLANAR CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    E. G. Sannikova

    2016-01-01

    Full Text Available The aim of the study is to develop new methods of identification and quantitative determination of rutin in the leaves of Salix triandra L. with thin-layer chromatography. The digital processing of the chromatograms was performed using «Sorbfil Videodensitometer» computer program (Krasnodar. For the chromatography analysis we used plates «Sorbfil» PTSH-P-A-UV, mobile phase: n-butanol-glacial acetic acid-water (4:1:1, detecting reagent – ammonia vapors. The rutin is detected as yellow spots with Rf 0.64±0.02. The detection limit is 0.5 μg/μl. The regression equation has the form: S=4.75×103 m. With the use of this method we found that the composition of rutin in leaves of Salix triandra was in the range 1.81±0.06% on the air-dry raw material (relative standard deviation RSD%=2.5%; the measurement error E=3.12%. The method is sensitive, linear, has a small error, and does not require expensive equipment.

  19. Method for 236U Determination in Seawater Using Flow Injection Extraction Chromatography and Accelerator Mass Spectrometry

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Steier, Peter

    2015-01-01

    An automated analytical method implemented in a flow injection (FI) system was developed for rapid determination of 236U in 10 L seawater samples. 238U was used as a chemical yield tracer for the whole procedure, in which extraction chromatography (UTEVA) was exploited to purify uranium, after...... experimental parameters affecting the analytical effectiveness were investigated and optimized in order to achieve high chemical yields and simple and rapid analysis as well as low procedure background. Besides, the operational conditions for the target preparation prior to the AMS measurement were optimized......, on the basis of studying the coprecipitation behavior of uranium with iron hydroxide. The analytical results indicate that the developed method is simple and robust, providing satisfactory chemical yields (80−100%) and high analysis speed (4 h/sample), which could be an appealing alternative to conventional...

  20. Instrumental liquid chromatography: a practical manual on high-performance liquid chromatographic methods

    National Research Council Canada - National Science Library

    Parris, N. A

    1976-01-01

    Available texts on liquid chromatography have tended to emphasize the developments in the theoretical understanding of the technique and methodology or to list numerous applications, complete with experimental details...

  1. Method development and optimization for the determination of benzene, toluene, ethylbenzene and xylenes in water at trace levels by static headspace extraction coupled to gas chromatography-barrier ionization discharge detection.

    Science.gov (United States)

    Pascale, Raffaella; Bianco, Giuliana; Calace, Stefania; Masi, Salvatore; Mancini, Ignazio M; Mazzone, Giuseppina; Caniani, Donatella

    2018-05-04

    Benzene, toluene, ethylbenzene, and xylenes, more commonly named BTEX, represent one of the most ubiquitous and hazardous groups of atmospheric pollutants. The goal of our research was the trace quantification of BTEX in water by using a new simple, low-cost, and accurate method, based on headspace (HS) extraction and gas chromatography (GC) coupled to barrier ionization discharge detector (BID). This water application dealt with simple matrices without protein, fat, or humic material that adsorb target analytes, thus the external standard calibration was suitable to quantify each compound. The validation steps included the study of linearity, detection and quantification limits, and accuracy. LODs and LOQs varied from 0.159 to 1.845 μg/L and from 0.202 to 2.452 μg/L, respectively. The recovery was between 0.74 ± 0.13 and 1.15 ± 0.09; relative standard deviations (% RDSs) were less than 12.81% (n = 5) and 14.84% (n = 10). Also, GC performance was evaluated in term of efficiency, peak tailing and resolution. Preliminary results from practical applications to analyses of real samples are presented. The results indicate that static HS coupled to GC-BID is a successful method for BTEX analysis in water samples at the μg/L levels, provided that hydrocarbons interference occur at similar concentration levels. GC-BID may become a routine reference method alongside the official analytical techniques for quality control purposes of contaminated waters. Moreover, the new method is amenable to automation by using commercial HS units. Copyright © 2018. Published by Elsevier B.V.

  2. Development of an ultrahigh-performance liquid chromatography-electrospray ionization-tandem mass spectrometry method for the simultaneous determination of salicylic acid, jasmonic acid, and abscisic acid in rose leaves.

    Science.gov (United States)

    Bosco, Renato; Daeseleire, Els; Van Pamel, Els; Scariot, Valentina; Leus, Leen

    2014-07-09

    This paper describes a method to detect and quantitate the endogenous plant hormones (±)-2-cis-4-trans-abscisic acid, (-)-jasmonic acid, and salicylic acid by means of ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) in hybrid rose leaf matrices. Deuterium-labeled [(2)H6] (+)-2-cis-4-trans-abscisic acid, [(2)H6] (±)-jasmonic acid, and [(2)H4]-salicylic acid were used as internal standards. Rose samples (10 mg) were extracted with methanol/water/acetic acid (10:89:1) and subsequently purified on an Oasis MCX 1 cm(3) Vac SPE cartridge. Performance characteristics were validated according to Commission Decision 2002/657/EC. Recovery, repeatability, and within-laboratory reproducibility were acceptable for all phytohormones tested at three different concentrations. The decision limit and detection capability for (±)-2-cis-4-trans-abscisic acid, (-)-jasmonic acid, and salicylic acid were 0.0075 and 0.015 μg/g, 0.00015 and 0.00030 μg/g, and 0.0089 and 0.018 μg/g, respectively. Matrix effects (signal suppression or enhancement) appeared to be high for all substances considered, implying the need for quantitation based on matrix-matched calibration curves.

  3. Sensitive method for the analysis of carbohydrates by gas chromatography of 3H-labeled alditol acetates

    International Nuclear Information System (INIS)

    Prehm, P.; Scheid, A.

    1978-01-01

    A highly sensitive method has been developed for the analysis of carbohydrates from glycoproteins or lipopolysaccharides. The method is based on labeling the carbohydrates with [ 3 H] sodium borohydride, acetylating the resulting alditols and separating them by gas chromatography. The gas effluent is fractionated by trapping on silicone-coated glass beads and the amount of radioactivity is determined. This permits the quantitation of as little as 0.2 nmoles monosaccharide with an accuracy of 10 to 15%. (Auth)

  4. A validated high performance thin layer chromatography method for determination of yohimbine hydrochloride in pharmaceutical preparations.

    Science.gov (United States)

    Badr, Jihan M

    2013-01-01

    Yohimbine is an indole alkaloid used as a promising therapy for erectile dysfunction. A number of methods were reported for the analysis of yohimbine in the bark or in pharmaceutical preparations. In the present work, a simple and sensitive high performance thin layer chromatographic method is developed for determination of yohimbine (occurring as yohimbine hydrochloride) in pharmaceutical preparations and validated according to International Conference of Harmonization (ICH) guidelines. The method employed thin layer chromatography aluminum sheets precoated with silica gel as the stationary phase and the mobile phase consisted of chloroform:methanol:ammonia (97:3:0.2), which gave compact bands of yohimbine hydrochloride. Linear regression data for the calibration curves of standard yohimbine hydrochloride showed a good linear relationship over a concentration range of 80-1000 ng/spot with respect to the area and correlation coefficient (R(2)) was 0.9965. The method was evaluated regarding accuracy, precision, selectivity, and robustness. Limits of detection and quantitation were recorded as 5 and 40 ng/spot, respectively. The proposed method efficiently separated yohimbine hydrochloride from other components even in complex mixture containing powdered plants. The amount of yohimbine hydrochloride ranged from 2.3 to 5.2 mg/tablet or capsule in preparations containing the pure alkaloid, while it varied from zero (0) to 1.5-1.8 mg/capsule in dietary supplements containing powdered yohimbe bark. We concluded that this method employing high performance thin layer chromatography (HPTLC) in quantitative determination of yohimbine hydrochloride in pharmaceutical preparations is efficient, simple, accurate, and validated.

  5. A high performance liquid chromatography method for determination of furfural in crude palm oil.

    Science.gov (United States)

    Loi, Chia Chun; Boo, Huey Chern; Mohammed, Abdulkarim Sabo; Ariffin, Abdul Azis

    2011-09-01

    A modified steam distillation method was developed to extract furfural from crude palm oil (CPO). The collected distillates were analysed using high performance liquid chromatography (HPLC) coupled with an ultraviolet diode detector at 284nm. The HPLC method allowed identification and quantification of furfural in CPO. The unique thermal extraction of CPO whereby the fresh fruit bunches (FFB) are first subjected to steam treatment, distinguishes itself from other solvent-extracted or cold-pressed vegetable oils. The presence of furfural was also determined in the fresh palm oil from FFB (without undergoing the normal extraction process), palm olein, palm stearin, olive oil, coconut oil, sunflower oil, soya oil and corn oil. The chromatograms of the extracts were compared to that of standard furfural. Furfural was only detected in CPO. The CPO consignments obtained from four mills were shown to contain 7.54 to 20.60mg/kg furfural. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Purification of human albumin by the combination of the method of Cohn with liquid chromatography

    Directory of Open Access Journals (Sweden)

    Tanaka K.

    1998-01-01

    Full Text Available Large volumes of plasma can be fractionated by the method of Cohn at low cost. However, liquid chromatography is superior in terms of the quality of the product obtained. In order to combine the advantages of each method, we developed an integrated method for the production of human albumin and immunoglobulin G (IgG. The cryoprecipitate was first removed from plasma for the production of factor VIII and the supernatant of the cryoprecipitate was fractionated by the method of Cohn. The first precipitate, containing fractions (F-I + II + III, was used for the production of IgG by the chromatographic method (see Tanaka K et al. (1998 Brazilian Journal of Medical and Biological Research, 31: 1375-1381. The supernatant of F-I + II + III was submitted to a second precipitation and F-IV was obtained and discarded. Albumin was obtained from the supernatant of the precipitate F-IV by liquid chromatography, ion-exchange on DEAE-Sepharose FF, filtration through Sephacryl S-200 HR and introduction of heat treatment for fatty acid precipitation. Viral inactivation was performed by pasteurization at 60ºC for 10 h. The albumin product obtained by the proposed procedure was more than 99% pure for the 15 lots of albumin produced, with a mean yield of 25.0 ± 0.5 g/l plasma, containing 99.0 to 99.3% monomer, 0.7 to 1.0% dimers, and no polymers. Prekallikrein activator levels were <=5 IU/ml. This product satisfies the requirements of the 1997 Pharmacopée Européenne.

  7. Analysis of residual toluene in food packaging via headspace extraction method using gas chromatography

    International Nuclear Information System (INIS)

    Lim, Ying Chin; Mohd Marsin Sanagi

    2008-01-01

    Polymeric materials are used in many food contact applications as packaging material. The presence of residual toluene in this food packaging material can migrate into food and thus affect the quality of food. In this study, a manual headspace analysis was successfully designed and developed. The determination of residual toluene was carried out with standard addition method and multiple headspace extraction, MHE) method using gas chromatography-flame ionization detector, GC-FID). Identification of toluene was performed by comparison of its retention time with standard toluene and GC-MS. It was found that the suitable heating temperature was 180 degree Celsius with an optimum heating time of 10 minutes. The study also found that the concentration of residual toluene in multicolored sample was higher compared to mono colored sample whereas residual toluene in sample analyzed using standard addition method was higher compared to MHE method. However, comparison with the results obtained from De Paris laboratory, France found that MHE method gave higher accuracy for sample with low analyte concentration. On the other hand, lower accuracy was obtained for sample with high concentration of residual toluene due to systematic errors. Comparison between determination methods showed that MHE method is more precise compared to standard addition method. (author)

  8. Integration of gas chromatography mass spectrometry methods for differentiating ricin preparation methods.

    Science.gov (United States)

    Wunschel, David S; Melville, Angela M; Ehrhardt, Christopher J; Colburn, Heather A; Victry, Kristin D; Antolick, Kathryn C; Wahl, Jon H; Wahl, Karen L

    2012-05-07

    The investigation of crimes involving chemical or biological agents is infrequent, but presents unique analytical challenges. The protein toxin ricin is encountered more frequently than other agents and is found in the seeds of Ricinus communis, commonly known as the castor plant. Typically, the toxin is extracted from castor seeds utilizing a variety of different recipes that result in varying purity of the toxin. Moreover, these various purification steps can also leave or differentially remove a variety of exogenous and endogenous residual components with the toxin that may indicate the type and number of purification steps involved. We have applied three gas chromatography-mass spectrometry (GC-MS) based analytical methods to measure the variation in seed carbohydrates and castor oil ricinoleic acid, as well as the presence of solvents used for purification. These methods were applied to the same samples prepared using four previously identified toxin preparation methods, starting from four varieties of castor seeds. The individual data sets for seed carbohydrate profiles, ricinoleic acid, or acetone amount each provided information capable of differentiating different types of toxin preparations across seed types. However, the integration of the data sets using multivariate factor analysis provided a clear distinction of all samples based on the preparation method, independent of the seed source. In particular, the abundance of mannose, arabinose, fucose, ricinoleic acid, and acetone were shown to be important differentiating factors. These complementary tools provide a more confident determination of the method of toxin preparation than would be possible using a single analytical method.

  9. Determination of 2-naphthylamine in urine by a novel reversed-phase high-performance liquid chromatography method

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Poulsen, O M; Christensen, J M

    1992-01-01

    A high-performance liquid chromatographic method for the determination of 2-naphthylamine in urine using fluorescence detection was developed. The method validation analysis showed the method to be in analytical control, i.e. the distribution of the difference between the observed and true values...... of the method evaluation samples did not deviate significantly from the normal distribution. The recovery of the method was 85%. The entire run time of chromatography was 10 min using isocratic elution (acetonitrile-water, 35:65), and the retention time for 2-naphthylamine was 5.8 min. The relative short time...

  10. Pesticides amenable to liquid chromatography: Multi Residue Method 2

    NARCIS (Netherlands)

    Baumann RA; Hogendoorn EA; van Zoonen P; LOC

    1996-01-01

    In dit rapport wordt een multiresidue methode voor de bepaling van bestrijdingsmiddelen met behulp van vloeistof-chromatografie in een grote verscheidenheid aan voedingsprodukten beschreven. De methode omvat N-methylcarbamaat pesticiden, fenylureum herbiciden en chloorfenoxy-azijnzuur herbiciden.

  11. Development of a thermal desorption modulator for gas chromatography

    NARCIS (Netherlands)

    Geus, H.J.; Boer, de J.; Brinkman, U.A.Th.

    1997-01-01

    The separation space in gas chromatography can be enhanced dramatically by the comprehensive coupling of two independent separation dimensions. An interface between the two columns must accumulate analytes eluting from the first dimension, focus them and at the appropriate moment transfer them to

  12. Ion counting method and it's operational characteristics in gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Fujii, Toshihiro

    1976-01-01

    Ion counting method with continuous channel electron multiplier which affords the direct detection of very small ion currents and it's operational characteristics were studied in gas chromatography-mass spectrometry. Then this method was applied to the single ion detection technique of GC-MS. A detection limit was measured, using various standard samples of low level concentration. (auth.)

  13. Cooperative method development

    DEFF Research Database (Denmark)

    Dittrich, Yvonne; Rönkkö, Kari; Eriksson, Jeanette

    2008-01-01

    The development of methods tools and process improvements is best to be based on the understanding of the development practice to be supported. Qualitative research has been proposed as a method for understanding the social and cooperative aspects of software development. However, qualitative...... research is not easily combined with the improvement orientation of an engineering discipline. During the last 6 years, we have applied an approach we call `cooperative method development', which combines qualitative social science fieldwork, with problem-oriented method, technique and process improvement....... The action research based approach focusing on shop floor software development practices allows an understanding of how contextual contingencies influence the deployment and applicability of methods, processes and techniques. This article summarizes the experiences and discusses the further development...

  14. Analytical method by high resolution liquid chromatography for the determination of carbamazepine in human plasma

    International Nuclear Information System (INIS)

    Jimenez Aleman, Narda M; Calero Carbonell, Jorge E; Padron Yaquis, Alejandro S; Izquierdo Lozano, Julio C

    2007-01-01

    One of the requirements to develop the studies of bioavailability and bioequivalence is to have analytic methodologies validated for the work with samples in biological fluids. A method was developed by high resolution liquid chromatography for the determination of carbamazepine in human plasma. A mixture of hydrogen phosphate of sodium: acetonitrile (65:35) adjusted to pH= 3.3 with phosphoric acid, flow of 1.2 mL/min and ultraviolet detection at 210 nm, was used as mobile phase. Propylparabene was used as an internal standard. According to the established regulations for the validation of the methods in biological fluids, the following parameters were studied: stability of the samples, lineality, specificity, precision, accuracy and limit of detection and quantification. The method proved to be specific and sensitive with a detection and quantification limit of 0.9 and 1.0 ng, respectively. The method was lineal, precise and exact in the range of concentrations of 1. 07 at 12.67 μg/mL. The mean recovery was not statistically different from 100.0 %. The analito in the proposed biological matrix remained in the studied period. The methodology described in this work is applied in our case to the study that evaluates the bioavailability and bioequivalence of a Cuban formulation of carbamazepine in healthy volunteers. (Author)

  15. A simplified but effective method for the quality control of medicinal plants by planar chromatography.

    Science.gov (United States)

    Eloff, J N; Ntloedibe, D T; van Brummelen, R

    2011-01-01

    Three of the factors limiting the rational use of herbal medicine are uncertainty on effectivity, uncertainty on safety and variation in quality of the product. Because many herbal medicines have been used over centuries by indigenous peoples, the safety and effectivity is frequently not such a big concern. With more people collecting and distributing herbal medicine, the offered product is however, frequently not what the label indicates either through a genuine mistake, but also through fraud especially where expensive herbal medicine is concerned. Some wrong identifications have already led to serious side effects and deaths. Planar chromatography or thin layer chromatography [TLC] is widely used to verify the identity of plant extracts by determining the chemical fingerprint of the extracts. In a leading publication 17 different extractants, 41 solvent systems and 44 spray reagents have been used to verify the identity of important herbal preparations. We investigated whether a simplified system could not be developed to aid small laboratories in identifying different herbal medicines. We compared the efficacy of different extractants, identified and developed three TLC solvent systems that would separate compounds with low, medium and high polarity and then also investigated the use of several spray reagents. With acetone as extractant and benzene:ethanol:ammonia [9:1:0.1], chloroform:ethylacetate:formic acid [5:4:1] and ethylacetate:methanol:water [10:1.35:1] as TLC solvent system and vanillin-sulphuric acid as spray reagent the identity of 81 samples of more than 50 herbal preparations could be verified on the basis of the chromatograms. The same product from different suppliers usually gave similar chromatograms. More importantly in several cases it was clear that products with the same label were so different that a mistake must have occurred in the labelling. This method has found application in the quality control of the most important African medicinal

  16. METHOD DEVELOPMENT FOR THE ANALYSIS OF N-NITROSODIMETHYLAMINE AND OTHER N-NITROSAMINES IN DRINKING WATER AT LOW NANOGRAM/LITER CONCENTRATIONS USING SOLID PHASE EXTRACTION AND GAS CHROMATOGRAPHY WITH CHEMICAL IONIZATION TANDEM MASS SPECTROMETRY

    Science.gov (United States)

    N-Nitrosodimethylamine (NDMA) is a probable human carcinogen that has been identified as a drinking water contaminant of concern. United States Environmental Protection Agency (USEPA) Method 521 has been developed for the analysis of NDMA and six additional N-nitrosamines in dri...

  17. Development and Application of Immunoaffinity Chromatography for Coplanar PCBs in Soil and Sediment

    Science.gov (United States)

    An immunoaffinity chromatography (IAC) column was developed as a simple cleanup procedure for preparing environmental samples for analysis of polychlorinated biphenyls (PCBs). Soil and sediment samples were prepared using pressurized liquid extraction (PLE), followed by the IAC c...

  18. Development and application of liquid chromatography coupled to isotope ratio mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Lijun

    2014-02-19

    evaluated for, isotope ratio mass spectrometry (HT-RPLC/IRMS). The effect of column bleed on measured isotope ratios was investigated at high temperature in isothermal mode and in temperature gradient mode. Four different revised-phase columns were proven to be compatible with IRMS for compound-specific isotope analysis. The developed method was applied to measure caffeine in different drinks. Naturally occurring and industrially synthesized caffeine was observed to have two distinct δ{sup 13}C-ranges, from -25 to -32% circle and from -33 to -38% circle, respectively. On the basis of two different δ{sup 13}C-ranges, four out of 38 drinks were suspected of being mislabelled due to added but non-labelled synthetic caffeine with δ{sup 13}C-values falling in the range of synthetic caffeine. Furthermore, HTLC/IRMS was applied to measure non-polar and water-insoluble compounds, here steroids, for the first time. The use of steroid isotope analysis for pharmaceutical product control by HTLC/IRMS was demonstrated. The major advantage is that steroids can be analysed without derivatization. By overcoming current limitations in sample preparation, the method might become applicable for doping control purposes. Another potential application of LC/IRMS in doping control is the isotope analysis of 5-Aminoimidazole-4-carboxamide ribonucleotide (AICAR), a gene doping drug. Here, the first method for compound-specific isotope analysis of AICAR has been presented. The endogenous AICAR in urine and industrially synthesized AICAR were observed to have significantly different isotope signature. It shows that isotope analysis of LC/IRMS could potentially be used for the detection of AICAR abuse. The methodological developments presented in the thesis will lead to new applications of LC/IRMS.

  19. Development and application of liquid chromatography coupled to isotope ratio mass spectrometry

    International Nuclear Information System (INIS)

    Zhang, Lijun

    2014-01-01

    evaluated for, isotope ratio mass spectrometry (HT-RPLC/IRMS). The effect of column bleed on measured isotope ratios was investigated at high temperature in isothermal mode and in temperature gradient mode. Four different revised-phase columns were proven to be compatible with IRMS for compound-specific isotope analysis. The developed method was applied to measure caffeine in different drinks. Naturally occurring and industrially synthesized caffeine was observed to have two distinct δ 13 C-ranges, from -25 to -32% circle and from -33 to -38% circle, respectively. On the basis of two different δ 13 C-ranges, four out of 38 drinks were suspected of being mislabelled due to added but non-labelled synthetic caffeine with δ 13 C-values falling in the range of synthetic caffeine. Furthermore, HTLC/IRMS was applied to measure non-polar and water-insoluble compounds, here steroids, for the first time. The use of steroid isotope analysis for pharmaceutical product control by HTLC/IRMS was demonstrated. The major advantage is that steroids can be analysed without derivatization. By overcoming current limitations in sample preparation, the method might become applicable for doping control purposes. Another potential application of LC/IRMS in doping control is the isotope analysis of 5-Aminoimidazole-4-carboxamide ribonucleotide (AICAR), a gene doping drug. Here, the first method for compound-specific isotope analysis of AICAR has been presented. The endogenous AICAR in urine and industrially synthesized AICAR were observed to have significantly different isotope signature. It shows that isotope analysis of LC/IRMS could potentially be used for the detection of AICAR abuse. The methodological developments presented in the thesis will lead to new applications of LC/IRMS.

  20. Downstream processing and chromatography based analytical methods for production of vaccines, gene therapy vectors, and bacteriophages

    Science.gov (United States)

    Kramberger, Petra; Urbas, Lidija; Štrancar, Aleš

    2015-01-01

    Downstream processing of nanoplexes (viruses, virus-like particles, bacteriophages) is characterized by complexity of the starting material, number of purification methods to choose from, regulations that are setting the frame for the final product and analytical methods for upstream and downstream monitoring. This review gives an overview on the nanoplex downstream challenges and chromatography based analytical methods for efficient monitoring of the nanoplex production. PMID:25751122

  1. A fast, comprehensive screening method for doping agents in urine by gas chromatography-triple quadrupole mass spectrometry.

    Science.gov (United States)

    Van Eenoo, Peter; Van Gansbeke, Wim; De Brabanter, Nik; Deventer, Koen; Delbeke, Frans T

    2011-05-27

    The use of performance enhancing drugs in sports is prohibited. For the detection of misuse of such substances gas chromatography or liquid chromatography coupled to mass spectrometry are the most frequently used detection techniques. In this work the development and validation of a fast gas chromatography tandem mass spectrometric method for the detection of a wide range of doping agents is described. The method can determine 13 endogenous steroids (the steroid profile), 19-norandrosterone, salbutamol and 11-nor-Δ9-tetrahydrocannabinol.9carboxylic acid in the applicable ranges and to detect qualitatively over 140 substances in accordance with the minimum required performance levels of the World Anti-Doping Agency in 1ml of urine. The classes of substances included in the method are anabolic steroids, β2-agonists, stimulants, narcotics, hormone antagonists and modulators and beta-blockers. Moreover, using a short capillary column and hydrogen as a carrier gas the run time of the method is less than 8min. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. A novel fast gas chromatography method for higher time resolution measurements of speciated monoterpenes in air

    Science.gov (United States)

    Jones, C. E.; Kato, S.; Nakashima, Y.; Kajii, Y.

    2014-05-01

    Biogenic emissions supply the largest fraction of non-methane volatile organic compounds (VOC) from the biosphere to the atmospheric boundary layer, and typically comprise a complex mixture of reactive terpenes. Due to this chemical complexity, achieving comprehensive measurements of biogenic VOC (BVOC) in air within a satisfactory time resolution is analytically challenging. To address this, we have developed a novel, fully automated Fast Gas Chromatography (Fast-GC) based technique to provide higher time resolution monitoring of monoterpenes (and selected other C9-C15 terpenes) during plant emission studies and in ambient air. To our knowledge, this is the first study to apply a Fast-GC based separation technique to achieve quantification of terpenes in ambient air. Three chromatography methods have been developed for atmospheric terpene analysis under different sampling scenarios. Each method facilitates chromatographic separation of selected BVOC within a significantly reduced analysis time compared to conventional GC methods, whilst maintaining the ability to quantify individual monoterpene structural isomers. Using this approach, the C9-C15 BVOC composition of single plant emissions may be characterised within a 14.5 min analysis time. Moreover, in-situ quantification of 12 monoterpenes in unpolluted ambient air may be achieved within an 11.7 min chromatographic separation time (increasing to 19.7 min when simultaneous quantification of multiple oxygenated C9-C10 terpenoids is required, and/or when concentrations of anthropogenic VOC are significant). These analysis times potentially allow for a twofold to fivefold increase in measurement frequency compared to conventional GC methods. Here we outline the technical details and analytical capability of this chromatographic approach, and present the first in-situ Fast-GC observations of 6 monoterpenes and the oxygenated BVOC (OBVOC) linalool in ambient air. During this field deployment within a suburban forest

  3. New EDTA determination method based on ion chromatography with suppressed conductimetric detection

    International Nuclear Information System (INIS)

    Gyoergy Patzay; Yahya Ramadan; Csilla Tonko

    2014-01-01

    A novel direct method for the determination of EDTA in alkaline radioactive evaporator residue solution was developed and validated based on ion chromatography with suppressed conductimetric detection and anion exchange columns (A Supp 4, 4 mm × 250 mm and A Supp 5, 4 mm × 150 mm). The yttrium-EDTA complex resulted one single chromatographic peak in the eluent and allowed the correct determination of EDTA in an alkaline, high concentration radioactive waste water. Depending on coexisting substances, suitable eluent is 10.0 mM carbonate buffer/pH 10.6 or 10.75 (t R ,Y-EDTA = 7.01 and 6.4 min, respectively). For 10.0 mM carbonate buffer/pH 10.6 and isocratic flow rate of 1.0 cm 3 /min, a linear calibration curve was obtained from 5 to 40 mg/dm 3 (r > 0.999) EDTA. Good resolution was achieved from commonly coexisting anions (chloride, nitrite, nitrate, sulphate, phosphate, bromide and citrate). The developed simple ion chromatographic method was applied for the assay of EDTA in various radioactive alkaline solutions. (author)

  4. High-throughput micro-scale cultivations and chromatography modeling: Powerful tools for integrated process development.

    Science.gov (United States)

    Baumann, Pascal; Hahn, Tobias; Hubbuch, Jürgen

    2015-10-01

    Upstream processes are rather complex to design and the productivity of cells under suitable cultivation conditions is hard to predict. The method of choice for examining the design space is to execute high-throughput cultivation screenings in micro-scale format. Various predictive in silico models have been developed for many downstream processes, leading to a reduction of time and material costs. This paper presents a combined optimization approach based on high-throughput micro-scale cultivation experiments and chromatography modeling. The overall optimized system must not necessarily be the one with highest product titers, but the one resulting in an overall superior process performance in up- and downstream. The methodology is presented in a case study for the Cherry-tagged enzyme Glutathione-S-Transferase from Escherichia coli SE1. The Cherry-Tag™ (Delphi Genetics, Belgium) which can be fused to any target protein allows for direct product analytics by simple VIS absorption measurements. High-throughput cultivations were carried out in a 48-well format in a BioLector micro-scale cultivation system (m2p-Labs, Germany). The downstream process optimization for a set of randomly picked upstream conditions producing high yields was performed in silico using a chromatography modeling software developed in-house (ChromX). The suggested in silico-optimized operational modes for product capturing were validated subsequently. The overall best system was chosen based on a combination of excellent up- and downstream performance. © 2015 Wiley Periodicals, Inc.

  5. Interlaboratory study of a liquid chromatography method for erythromycin: determination of uncertainty.

    Science.gov (United States)

    Dehouck, P; Vander Heyden, Y; Smeyers-Verbeke, J; Massart, D L; Marini, R D; Chiap, P; Hubert, Ph; Crommen, J; Van de Wauw, W; De Beer, J; Cox, R; Mathieu, G; Reepmeyer, J C; Voigt, B; Estevenon, O; Nicolas, A; Van Schepdael, A; Adams, E; Hoogmartens, J

    2003-08-22

    Erythromycin is a mixture of macrolide antibiotics produced by Saccharopolyspora erythreas during fermentation. A new method for the analysis of erythromycin by liquid chromatography has previously been developed. It makes use of an Astec C18 polymeric column. After validation in one laboratory, the method was now validated in an interlaboratory study. Validation studies are commonly used to test the fitness of the analytical method prior to its use for routine quality testing. The data derived in the interlaboratory study can be used to make an uncertainty statement as well. The relationship between validation and uncertainty statement is not clear for many analysts and there is a need to show how the existing data, derived during validation, can be used in practice. Eight laboratories participated in this interlaboratory study. The set-up allowed the determination of the repeatability variance, s(2)r and the between-laboratory variance, s(2)L. Combination of s(2)r and s(2)L results in the reproducibility variance s(2)R. It has been shown how these data can be used in future by a single laboratory that wants to make an uncertainty statement concerning the same analysis.

  6. Determination of nucleosides in Cordyceps sinensis and Ganoderma lucidum by high performance liquid chromatography method

    Directory of Open Access Journals (Sweden)

    Masood Shah Khan

    2015-01-01

    Full Text Available Background: Nucleosides are supportive in the regulation and modulation of various physiological processes in body, they acts as precursors in nucleic acid synthesis, enhance immune response, help in absorption of iron and influence the metabolism of fatty acids. Cordyceps sinensis and Ganoderma lucidum are well-known for its use in traditional medicine of China, Nepal and India. They are rich in nucleosides such as adenine, adenosine, cordycepin, etc. Hence, a simple, economic and accurate high-performance liquid chromatography (HPLC analytical method was proposed for determination of adenine and adenosine for the quality control of plants. Materials and Methods: Chromatographic experiments were conducted on YL9100 HPLC system (South Korea. Reversed-phase chromatography was performed on a C18 column with methanol and dihydrogen phosphate as the mobile phase in isocratic elution method at a flow rate of 1.0 mL/min. Detection was carried out at 254 nm, which gives a sharp peak of adenine and adenosine at a retention time of 6.53 ± 0.02 min and 12.41 ± 0.02, respectively. Results and Discussion: Linear regression analysis data for the calibration plot showed a good linear relationship between response and concentration in the range of 25–200 µg/mL for adenosine and 100–800 µg/mL for adenine with regression coefficient of 0.999 and 0.996, respectively. The adenine was found 0.16% and 0.71% w/w in G. lucidum and in C. sinensis, respectively, and adenosine was found to be 0.14% w/w in G. lucidum whereas absent in C. sinensis. Conclusion: The developed HPLC method for the quantification of adenosine and adenine can be used for the quality control and standardization of crude drug and for the different herbal formulations, in which adenine and adenosine are present as major constituents. The wide linearity range, sensitivity, accuracy, and simple mobile phase imply the method is suitable for routine quantification of adenosine and adenine with

  7. Development of a large volume injection method using a programmed temperature vaporization injector - gas chromatography hyphenated to ICP-MS for the simultaneous determination of mercury, tin and lead species at ultra-trace levels in natural waters.

    Science.gov (United States)

    Terán-Baamonde, J; Bouchet, S; Tessier, E; Amouroux, D

    2018-04-27

    The current EU legislation lays down Environmental Quality Standards (EQS) for 45 priority substances in surface waters; among them levels for (organo)metallic species of Hg, Sn and Pb are set between ng L -1 (for Hg and Sn) and μg L -1 (for Pb). To date, only a few analytical methods can reach these very restrictive limits and there is thus a need for comprehensive methods able to analyze these species down to these levels in natural waters. The aim of this work was to develop an online automated pre-concentration method using large volume injections with a Programmed Temperature Vaporization (PTV) injector fitted with a sorbent packed liner coupled to GC-ICP-MS to further improve the detection limits associated to this well-established method. The influence of several parameters such as the PTV transfer temperature and time, carrier gas flow rate and amount of packing material was investigated. Finally, the maximum volume injected through single or multiple injection modes was optimized to obtain the best compromise between chromatographic resolution and sensitivity. After optimization, very satisfactory results in terms of absolute and methodological detection limits were achieved, down to the pg L -1 level for all species studied. The potential of the method was exemplified by determining the concentrations of organometallic compounds in unpolluted river waters samples from the Adour river basin (SW France) and results were compared with conventional (splitless) GC-ICP-MS. The strength of this analytical method lies in the low detection limits reached for the simultaneous analysis of a wide group of organometallic compounds, and the potential to transfer this method to other gas chromatographic applications with inherent lower sensitivity. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Liquid chromatography-high resolution mass spectrometric methods for the surveillance monitoring of cyanotoxins in freshwaters.

    Science.gov (United States)

    Bogialli, Sara; Bortolini, Claudio; Di Gangi, Iole Maria; Di Gregorio, Federica Nigro; Lucentini, Luca; Favaro, Gabriella; Pastore, Paolo

    2017-08-01

    A comprehensive risk management on human exposure to cyanotoxins, whose production is actually unpredictable, is limited by reliable analytical tools for monitoring as many toxic algal metabolites as possible. Two analytical approaches based on a LC-QTOF system for target analysis and suspect screening of cyanotoxins in freshwater were presented. A database with 369 compounds belonging to cyanobacterial metabolites was developed and used for a retrospective data analysis based on high resolution mass spectrometry (HRMS). HRMS fragmentation of the suspect cyanotoxin precursor ions was subsequently performed for correctly identifying the specific variants. Alternatively, an automatic tandem HRMS analysis tailored for cyanotoxins was performed in a single chromatographic run, using the developed database as a preferred precursor ions list. Twenty-five extracts of surface and drinking waters contaminated by cyanobacteria were processed. The identification of seven uncommon microcystins (M(O)R, MC-FR, MSer 7 -YR, D-Asp 3 MSer 7 -LR, MSer 7 -LR, dmAdda-LR and dmAdda-YR) and 6 anabaenopeptins (A, B, F, MM850, MM864, oscyllamide Y) was reported. Several isobaric variants, fully separated by chromatography, were pointed out. The developed methods are proposed to be used by environmental and health agencies for strengthening the surveillance monitoring of cyanotoxins in water. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Supercritical fluid chromatography for GMP analysis in support of pharmaceutical development and manufacturing activities.

    Science.gov (United States)

    Hicks, Michael B; Regalado, Erik L; Tan, Feng; Gong, Xiaoyi; Welch, Christopher J

    2016-01-05

    Supercritical fluid chromatography (SFC) has long been a preferred method for enantiopurity analysis in support of pharmaceutical discovery and development, but implementation of the technique in regulated GMP laboratories has been somewhat slow, owing to limitations in instrument sensitivity, reproducibility, accuracy and robustness. In recent years, commercialization of next generation analytical SFC instrumentation has addressed previous shortcomings, making the technique better suited for GMP analysis. In this study we investigate the use of modern SFC for enantiopurity analysis of several pharmaceutical intermediates and compare the results with the conventional HPLC approaches historically used for analysis in a GMP setting. The findings clearly illustrate that modern SFC now exhibits improved precision, reproducibility, accuracy and robustness; also providing superior resolution and peak capacity compared to HPLC. Based on these findings, the use of modern chiral SFC is recommended for GMP studies of stereochemistry in pharmaceutical development and manufacturing. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Development of a highly sensitive methodology for quantitative determination of fexofenadine in a microdose study by multiple injection method using ultra-high performance liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Tanaka, Yukari; Yoshikawa, Yutaka; Yasui, Hiroyuki

    2012-01-01

    An ultra high-sensitivity method for quantifying fexofenadine concentration in rat plasma samples by multiple injection method (MIM) was developed for a microdose study. In this study, MIM involved continuous injections of multiple samples containing the single compound into a column of the ultra-HPLC (UHPLC) system, and then, temporary trapping of the analyte at the column head. This was followed by elution of the compound from the column and detection by mass spectrometer. Fexofenadine, used as a model compound in this study, was extracted from the plasma samples by a protein precipitation method. Chromatographic separation was achieved on a reversed-phase C18 column by using a gradient method with 0.1% formic acid and 0.1% formic acid in acetonitrile as the mobile phase. The analyte was quantified in the positive-ion electrospray ionization mode using selected reaction monitoring. In this study, the analytical time per fexofenadine sample was approximately 2 min according to the UHPLC system. The method exhibited the linear dynamic ranges of 5-5000 pg/mL for fexofenadine in rat plasma. The intra-day precisions were from 3.2 to 8.7% and the accuracy range was 95.2-99.3%. The inter-day precisions and accuracies ranged from 3.5 to 8.4% and from 98.6 to 102.6%, respectively. The validated MIM was successfully applied to a microdose study in the rats that received oral administration of 100 µg/kg fexofenadine. We suggest that this method might be beneficial for the quantification of fexofenadine concentrations in a microdose clinical study.

  11. Volumetric adsorptive microsampling-liquid chromatography tandem mass spectrometry assay for the simultaneous quantification of four antibiotics in human blood: Method development, validation and comparison with dried blood spot.

    Science.gov (United States)

    Barco, Sebastiano; Castagnola, Elio; Moscatelli, Andrea; Rudge, James; Tripodi, Gino; Cangemi, Giuliana

    2017-10-25

    In this paper we show the development and validation of a volumetric absorptive microsampling (VAMS™)-LC-MS/MS method for the simultaneous quantification of four antibiotics: piperacillin-tazobactam, meropenem, linezolid and ceftazidime in 10μL human blood. The novel VAMS-LC-MS/MS method has been compared with a dried blood spot (DBS)-based method in terms of impact of hematocrit (HCT) on accuracy, reproducibility, recovery and matrix effect. Antibiotics were extracted from VAMS and DBS by protein precipitation with methanol after a re-hydration step at 37°C for 10min. LC-MS/MS was carried out on a Thermo Scientific™ TSQ Quantum™ Access MAX triple quadrupole coupled to an Accela ™UHPLC system. The VAMS-LC-MS/MS method is selective, precise and reproducible. In contrast to DBS, it allows an accurate quantification without any HCT influence. It has been applied to samples derived from pediatric patients under therapy. VAMS is a valid alternative sampling strategy for the quantification of antibiotics and is valuable in support of clinical PK/PD studies and consequently therapeutic drug monitoring (TDM) in pediatrics. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. GEM simulation methods development

    International Nuclear Information System (INIS)

    Tikhonov, V.; Veenhof, R.

    2002-01-01

    A review of methods used in the simulation of processes in gas electron multipliers (GEMs) and in the accurate calculation of detector characteristics is presented. Such detector characteristics as effective gas gain, transparency, charge collection and losses have been calculated and optimized for a number of GEM geometries and compared with experiment. A method and a new special program for calculations of detector macro-characteristics such as signal response in a real detector readout structure, and spatial and time resolution of detectors have been developed and used for detector optimization. A detailed development of signal induction on readout electrodes and electronics characteristics are included in the new program. A method for the simulation of charging-up effects in GEM detectors is described. All methods show good agreement with experiment

  13. Development and Validation of a Reversed-Phase Liquid Chromatography Method for the Simultaneous Determination of Indole-3-Acetic Acid, Indole-3-Pyruvic Acid, and Abscisic Acid in Barley (Hordeum vulgare L.

    Directory of Open Access Journals (Sweden)

    Ilva Nakurte

    2012-01-01

     mm I.D with a mobile phase composed of methanol and 1% acetic acid (60 : 40 v/v in isocratic mode at a flow rate of 1 ml min-1. The detection was monitored at 270 nm (ABA and at 282 nm (Ex and 360 nm (Em (IAA, IPA. The developed method was validated in terms of accuracy, precision, linearity, limit of detection, limit of quantification, and robustness. The determined validation parameters are in the commonly acceptable ranges for that kind of analysis.

  14. Determination of Alternaria mycotoxins in wine and juice using ionic liquid modified countercurrent chromatography as a pretreatment method followed by high-performance liquid chromatography.

    Science.gov (United States)

    Fan, Chen; Cao, Xueli; Liu, Man; Wang, Wei

    2016-03-04

    Alternariol (AOH), alternariol monomethyl ether (AME), and tenuazonic acid (TeA) are some of the main Alternaria mycotoxins that can be found as contaminants in food materials. The objective of this study was to develop a pretreatment method with countercurrent chromatography (CCC) for enrichment and cleanup of trace Alternaria mycotoxins in food samples prior to high-performance liquid chromatography (HPLC) analysis. An Analytical CCC instrument with a column volume 22.5mL was used, and a two-phase solvent system composed of ethyl acetate and water modified with 6% [HOOMIM][Cl] in mass to volume ratio was selected. Under the optimized CCC operation conditions, trace amounts of AOH, AME, and TeA in large volume of liquid sample were efficiently extracted and enriched in the stationary phase, and then eluted out just by reversing the stationary phase as mobile phase in the opposite flowing direction tail-to-head. The enrichment and elution strategies are unique and can be fulfilled online with high enrichment factors (87-114) and high recoveries (81.14-110.94%). The method has been successively applied to the determination of Alternaria mycotoxins in real apple juice and wine samples with the limits of detection (LOD) in the range of 0.03-0.14μgL(-1). Totally 12 wine samples and 15 apple juice samples from the local market were analyzed. The detection rate of AOH and AME in both kinds of the samples were more than 50%, while TeA was found in relatively high level of 1.75-49.61μgL(-1) in some of the apple juice samples. The proposed method is simple, rapid, and sensitive and could also be used for the analysis and monitoring of Alternaria mycotoxin in other food samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. A new high-performance liquid chromatography-tandem mass spectrometry method for the determination of paclitaxel and 6α-hydroxy-paclitaxel in human plasma: Development, validation and application in a clinical pharmacokinetic study.

    Directory of Open Access Journals (Sweden)

    Bianca Posocco

    Full Text Available Paclitaxel belongs to the taxanes family and it is used, alone or in multidrug regimens, for the therapy of several solid tumours, such as breast-, lung-, head and neck-, and ovarian cancer. Standard dosing of chemotherapy does not take into account the many inter-patient differences that make drug exposure highly variable, thus leading to the insurgence of severe toxicity. This is particularly true for paclitaxel considering that a relationship between haematological toxicity and plasma exposure was found. Therefore, in order to treat patients with the correct dose of paclitaxel, improving the overall benefit-risk ratio, Therapeutic Drug Monitoring is necessary. In order to quantify paclitaxel and its main metabolite, 6α-hydroxy-paclitaxel, in patients' plasma, we developed a new, sensitive and specific HPLC-MS/MS method applicable to all paclitaxel dosages used in clinical routine. The developed method used a small volume of plasma sample and is based on quick protein precipitation. The chromatographic separation of the analytes was achieved with a SunFire™ C18 column (3.5 μM, 92 Å, 2,1 x 150 mm; the mobile phases were 0.1% formic acid/bidistilled water and 0.1% formic acid/acetonitrile. The electrospray ionization source worked in positive ion mode and the mass spectrometer operated in selected reaction monitoring mode. Our bioanalytical method was successfully validated according to the FDA-EMA guidelines on bioanalytical method validation. The calibration curves resulted linear (R2 ≥0.9948 over the concentration ranges (1-10000 ng/mL for paclitaxel and 1-1000 ng/mL for 6α-hydroxy-paclitaxel and were characterized by a good accuracy and precision. The intra- and inter-day precision and accuracy were determined on three quality control concentrations for paclitaxel and 6α-hydroxy-paclitaxel and resulted respectively <9.9% and within 91.1-114.8%. In addition, to further verify the assay reproducibility, we tested this method by re

  16. A reversed-phase high-performance liquid chromatography method for the determination of cotrimoxazole (trimethoprim/ sulphamethoxazole) in children treated for malaria

    DEFF Research Database (Denmark)

    Rønn, A M; Mutabingwa, T K; Kreisby, S

    1999-01-01

    A high-performance liquid chromatography (HPLC) method was developed for the simultaneous analysis of trimethoprim (TMP), sulphamethoxazole (SMX), and acetylsulphamethoxazole (AcSMX) in small amounts of blood. The method involved precipitation with 50 microL trichloracetic acid (1M) to 125 micro...

  17. Hydrophilic interaction liquid chromatography method for measuring the composition of aquatic humic substances

    KAUST Repository

    Wang, Renqi; Gutié rrez, Leonardo A.; Ng, Siuchoon; Croue, Jean-Philippe

    2015-01-01

    A hydrophilic interaction liquid chromatography (HILIC) method was developed to measure the composition of humic substances from river, reservoir, and treated wastewater based on their physicochemical properties. The current method fractionates the humic substances into four well-defined groups based on parallel analyses with a neutral and a cationic HILIC column, using mobile phases of varied compositions and pH. The results indicate that: (i) the proportion of carboxylic acids in the humic substances from terrestrial origins is less than half of that from treated wastewater (Jeddah, KSA), (ii) a higher content of basic compounds was observed in the humic substances from treated wastewater and Ribou Reservoir (Cholet, France) than in the sample from Loire River (France), (iii) a higher percentage of hydrophobic macromolecules were found in the humic substances from Loire River than in the other samples, and (iv) humic substances of treated wastewater contained less ionic neutral compounds (i.e., pKa 5-9) than the waters from terrestrial origins. The physicochemical property disparity amongst the compounds in each humic substances sample was also evaluated. The humic substances from the lightly humic Loire river displayed the highest disparity, whereas the highly humic Suwannee river (Georgia, USA) showed the most homogeneous humic substances.

  18. Sensitive liquid chromatography-tandem mass spectrometry method for quantification of hydrochlorothiazide in human plasma.

    Science.gov (United States)

    Ramakrishna, N V S; Vishwottam, K N; Manoj, S; Koteshwara, M; Wishu, S; Varma, D P

    2005-12-01

    A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of hydrochlorothiazide (I), a common diuretic and anti-hypertensive agent. The analyte and internal standard, tamsulosin (II) were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reversed-phase column (Waters symmetry C18) with a mobile phase of 10 mm ammonium acetate-methanol (15:85, v/v). The protonated analyte was quantitated in negative ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 296.1 solidus in circle 205.0 and m/z 407.2 solidus in circle 184.9 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.5-200 ng/mL for hydrochlorothiazide in human plasma. The lower limit of quantitation was 500 pg/mL, with a relative standard deviation of less than 9%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.5 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. (c) 2005 John Wiley & Sons, Ltd.

  19. Analysis of Fluconazole in Human Urine Sample by High Performance Liquid Chromatography Method

    International Nuclear Information System (INIS)

    Hermawan, D; Ali, N A Md; Ibrahim, W A Wan; Sanagi, M M

    2013-01-01

    A method for determination of fluconazole, antifungal drug in human urine by using reversed-phased high performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detector was developed. Optimization HPLC conditions were carried out by changing the flow rate and composition of mobile phase. The optimum separation conditions at a flow rate 0.85 mL/min with a composition of mobile phase containing methanol:water (70:30, v/v) with UV detection at a wavelength 254 nm was able to analyze fluconazole within 3 min. The excellent linearity was obtained in the range of concentration 1 to 10 μg/mL with r 2 = 0.998. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.39 μg/mL and 1.28 μg/mL, respectively. Solid phase extraction (SPE) method using octadecylsilane (C18) as a sorbent was used to clean-up and pre-concentrated of the urine sample prior to HPLC analysis. The average recoveries of fluconazole in spiked urine sample was 72.4% with RSD of 3.21% (n=3).

  20. Methods in endogenous steroid profiling - A comparison of gas chromatography mass spectrometry (GC-MS) with supercritical fluid chromatography tandem mass spectrometry (SFC-MS/MS).

    Science.gov (United States)

    Teubel, Juliane; Wüst, Bernhard; Schipke, Carola G; Peters, Oliver; Parr, Maria Kristina

    2018-06-15

    In various fields of endocrinology, the determination of steroid hormones synthesised by the human body plays an important role. Research on central neurosteroids has been intensified within the last years, as they are discussed as biomarkers for various cognitive disorders. Their concentrations in cerebrospinal fluid (CSF) are considered to be regulated independently from peripheral fluids. For that reason, the challenging matrix CSF becomes a very interesting specimen for analysis. Concentrations are expected to be very low and available amount of CSF is limited. Thus, a comprehensive method for very sensitive quantification of a set of analytes as large as possible in one analytical aliquot is desired. However, high structural similarities of the selected panel of 51 steroids and steroid sulfates, including numerous isomers, challenges achievement of chromatographic selectivity. Since decades the analysis of endogenous steroids in various body fluids is mainly performed by gas chromatography (GC) coupled to (tandem) mass spectrometry (MS(/MS)). Due to the structure of the steroids of interest, derivatisation is performed to meet the analytical requirements for GC-MS(/MS). Most of the laboratories use a two-step derivatisation in multi-analyte assays that was already published in the 1980s. However, for some steroids this elaborate procedure yields multiple isomeric derivatives. Thus, some laboratories utilize (ultra) high performance liquid chromatography ((U)HPLC)-MS/MS as alternative but, even UHPLC is not able to separate some of the isomeric pairs. Supercritical fluid chromatography (SFC) as an orthogonal separation technique to GC and (U)HPLC may help to overcome these issues. Within this project the two most promising methods for endogenous steroid profiling were investigated and compared: the "gold standard" GC-MS and the orthogonal separation technique SFC-MS/MS. Different derivatisation procedures for gas chromatographic detection were explored and the

  1. New radiochemical methods for determination of 237Np a 241Pu using extraction chromatography (Presentation)

    International Nuclear Information System (INIS)

    Strisovska, J.

    2013-01-01

    Thesis was focused on the development of a new methodology for the separation of anthropogenic transuranium radionuclides 237 Np a 241 Pu from different kinds of matrices. The analytical methods used in this study were based on extraction chromatography and were optimized according to the sample type. The proposed radiochemical procedure is a combination of two algorithms, which represent the separation of radionuclides by using extraction chromatographic sorbents TEVA resin and TRU resin supplied by Eichrom Technologies LLC. 239 Np a 237 Np were selectively captured on sorbent TEVA resin in oxidation state 4+. TRU resin was used for purification of plutonium fraction from interfering americium radionuclide. 242 Pu and 239 Np radionuclides as tracers have been used to monitor the radiochemical yields of separation. Before every radiochemical separation tracer radionuclide 239 Np was obtained by separation from the parent radionuclide 2 43 Am, which is in radioactive equilibrium to 239 Np. The average yield of chemical separation was 69,3% for 239 Np at 277 keV energy line and 65,9% at 228 keV energy line. The NPL AH-B08069 (2008) samples which consist of the mixture of alpha-radionuclides were used for the modification and optimization of separation method used for separation of Np and Pu in model samples. This method provided high radiochemical yields of 239,240 Pu (95,0 ± 3,5)% and 237 Np (87,9 ± 3,0)%.. Reliability of the method was verified by applying our modified separation procedures on reference materials IAEA-375 and IAEA-414 supplied by International Atomic Energy Agency. A good agreement between the results is obtained by this procedure and the certified values were found. Samples of contaminated soils from the area of Nuclear power plant A-1 Jaslovske Bohunice which is stored temporarily before disposal were analyzed using developed separation procedure. Specific activity of investigated radionuclides was determined in these samples. (author)

  2. Development of a method for the analysis of hormones and pharmaceuticals in earthworms by quick, easy, cheap, effective, rugged and safe (QuEChERS) extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS).

    Science.gov (United States)

    Bergé, Alexandre; Vulliet, Emmanuelle

    2015-10-01

    The earthworm represents a kind of creature in contact with the soil surface and usually exposed to a variety of organic pollutants from human activities. Therefore, it can be considered as an organism of choice for identifying pollution or better understanding the input of contaminants in food chains in particular through the contributions of sludge. Moreover, the use of organisms such as soil invertebrates is to be developed for ecotoxicological risk assessment of pollutants. In this context, a simple, rapid and effective multi-residue method was developed for the determination of 31 compounds including 11 steroids, 14 veterinary antibiotics and 6 human contaminants (paracetamol, sulfamethoxazole, fluvoxamine, carbamazepine, ibuprofen, bisphenol A) in earthworm. The sample preparation procedure was based on a salting-out extraction with acetonitrile (QuEChERS approach) that was optimised with regard to the acetonitrile/water ratio used in the extraction step, the choice of the clean-up and the quantity of the matrix. The optimised extraction method exhibited recoveries that comprised between 44 and 98 % for all the tested compounds. The limits of detection of all compounds were below 14 ng g(-1) and the limits of quantification (LOQ) comprised between 1.6 and 40 ng g(-1) (wet weight). The method was therefore applied to determine the levels of pharmaceuticals and hormones in six earthworm samples collected in various soils. Concentrations up to 195 ng g(-1) for bisphenol A were determined, between a few nanograms per gram and 43.1 ng g(-1) (estriol) for hormones and between a few nanograms per gram and 73.5 ng g(-1) (florfenicol) for pharmaceuticals. Experiments were also conducted in laboratory conditions to evaluate the accumulation of the target substances by earthworm.

  3. Method of determining of polybrominated diphenyl ethers in fish and fish products by the method of liquid chromatography

    Directory of Open Access Journals (Sweden)

    O.N. Timofeeva

    2016-09-01

    Full Text Available The aim of the work was to develop a methodology for determining of polybrominated diphenyl ethers (PBDE in fish and fish products for the control of impurities content in the food and environmental objects in general. The conditions of chromatography (temperature conditions, the impact of the speed and magnitude of dividing of the gas-carrier stream using a HP-1 capillary columns, the DB-5, HP-50 +, DB-1; and lipids destructive and non-destructive cleaning methods of extract during the determination of PBDEs. The method of determination of 2,2,4,4-Tetrabromodiphenyl ether (BDE-47, 2,2,4,4,5-pentabromodiphenyl ether (BDE-99 and decabromodiphenyl ether (BDE-209 in fish and fish products by the liquid chromatography with electron detector was suggested. The method of PBDE is based on the extraction of samples with hexane-acetone (3:1, purification of the extract with concentrated sulfuric acid (phase ratio hexane-sulfuric acid – 5:1. The second purification step is carried out by using solid phase extraction cartridges «SiOH-H2SO4/SA» and hexane as the eluent. Gas chromatographic analysis of the determination of BDE-47 and BDE-99 is carried out on low-polar capillary column DB-5 (30 m x0.25 mm x0.25 mum with the programming of the column temperature. In determining the BDE-209 a DB-1 nonpolar capillary column was used (15 m x 0.25 mm x 0.1 mum with the column temperature programming. Calculation of the content of BDE-47 and BDE-99 is carried out with the internal standard (2,2, 3,4,4-pentabromodiphenyl ether (BDE-85, BDE-209 by absolute calibration. In determining the BDE-209 the calibration matrix was used. The range of concentrations of the calibration solutions for the determination of BDE-47 and BDE-99 is 0.005–0.05 g/cm 3 , for BDE-209 0.05–0.3 g/cm 3 . The technique allows the measurement of BDE-47 and BDE-99 in the range of 0.0002–0.05 mg/kg of the product concerned; BDE-209 – in the range of 0.002–0.3 mg/kg. The metrological

  4. Innovative high-performance liquid chromatography method development for the screening of 19 antimalarial drugs based on a generic approach, using design of experiments, independent component analysis and design space.

    Science.gov (United States)

    Debrus, B; Lebrun, P; Kindenge, J Mbinze; Lecomte, F; Ceccato, A; Caliaro, G; Mbay, J Mavar Tayey; Boulanger, B; Marini, R D; Rozet, E; Hubert, Ph

    2011-08-05

    An innovative methodology based on design of experiments (DoE), independent component analysis (ICA) and design space (DS) was developed in previous works and was tested out with a mixture of 19 antimalarial drugs. This global LC method development methodology (i.e. DoE-ICA-DS) was used to optimize the separation of 19 antimalarial drugs to obtain a screening method. DoE-ICA-DS methodology is fully compliant with the current trend of quality by design. DoE was used to define the set of experiments to model the retention times at the beginning, the apex and the end of each peak. Furthermore, ICA was used to numerically separate coeluting peaks and estimate their unbiased retention times. Gradient time, temperature and pH were selected as the factors of a full factorial design. These retention times were modelled by stepwise multiple linear regressions. A recently introduced critical quality attribute, namely the separation criterion (S), was also used to assess the quality of separations rather than using the resolution. Furthermore, the resulting mathematical models were also studied from a chromatographic point of view to understand and investigate the chromatographic behaviour of each compound. Good adequacies were found between the mathematical models and the expected chromatographic behaviours predicted by chromatographic theory. Finally, focusing at quality risk management, the DS was computed as the multidimensional subspace where the probability for the separation criterion to lie in acceptance limits was higher than a defined quality level. The DS was computed propagating the prediction error from the modelled responses to the quality criterion using Monte Carlo simulations. DoE-ICA-DS allowed encountering optimal operating conditions to obtain a robust screening method for the 19 considered antimalarial drugs in the framework of the fight against counterfeit medicines. Moreover and only on the basis of the same data set, a dedicated method for the

  5. Supercritical fluid chromatography

    Science.gov (United States)

    Vigdergauz, M. S.; Lobachev, A. L.; Lobacheva, I. V.; Platonov, I. A.

    1992-03-01

    The characteristic features of supercritical fluid chromatography (SCFC) are examined and there is a brief historical note concerning the development of the method. Information concerning the use of supercritical fluid chromatography in the analysis of objects of different nature is presented in the form of a table. The roles of the mobile and stationary phases in the separation process and the characteristic features of the apparatus and of the use of the method in physicochemical research are discussed. The bibliography includes 364 references.

  6. Centrifugal partition chromatography enables selective enrichment of trimeric and tetrameric proanthocyanidins for biomaterial development.

    Science.gov (United States)

    Phansalkar, Rasika S; Nam, Joo-Won; Chen, Shao-Nong; McAlpine, James B; Leme, Ariene A; Aydin, Berdan; Bedran-Russo, Ana-Karina; Pauli, Guido F

    2018-02-02

    Proanthocyanidins (PACs) find wide applications for human use including food, cosmetics, dietary supplements, and pharmaceuticals. The chemical complexity associated with PACs has triggered the development of various chromatographic techniques, with countercurrent separation (CCS) gaining in popularity. This study applied the recently developed DESIGNER (Depletion and Enrichment of Select Ingredients Generating Normalized Extract Resources) approach for the selective enrichment of trimeric and tetrameric PACs using centrifugal partition chromatography (CPC). This CPC method aims at developing PAC based biomaterials, particularly for their application in restoring and repairing dental hard tissue. A general separation scheme beginning with the depletion of polymeric PACs, followed by the removal of monomeric flavan-3-ols and a final enrichment step produced PAC trimer and tetramer enriched fractions. A successful application of this separation scheme is demonstrated for four polyphenol rich plant sources: grape seeds, pine bark, cinnamon bark, and cocoa seeds. Minor modifications to the generic DESIGNER CCS method were sufficient to accommodate the varying chemical complexities of the individual source materials. The step-wise enrichment of PAC trimers and tetramers was monitored using normal phase TLC and Diol-HPLC-UV analyses. CPC proved to be a reliable tool for the selective enrichment of medium size oligomeric PACs (OPACs). This method plays a key role in the development of dental biomaterials considering its reliability and reproducibility, as well as its scale-up capabilities for possible larger-scale manufacturing. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Two-step Purification Method for Aging Pigments A2E and Iso-A2E Using Medium Pressure Liquid Chromatography

    International Nuclear Information System (INIS)

    Park, Sang Il; Park, Sang Cheol; Kim, So Ra; Jang, Young Pyo

    2016-01-01

    A newly modified method for the efficient purification of A2E and iso-A2E using reverse phase silica gel resin with medium pressure liquid chromatography (MPLC) was suggested. MPLC is one of the various preparative column chromatography techniques and separation under pressure renders the use of smaller particle size resins possible and increases the diversity of available stationary phases. A simplified two-step purification method was developed for the purification of aging pigments in eye, A2E and iso-A2E. With simple two-step elution of mobile phase in reverse phase MPLC, A2E and iso-A2E were successfully purified with great efficiency compare with previous column chromatography and HPLC method. This method provides more simple, convenient, cost-effective, and less time-consuming procedure for mass purification of aging pigments A2E and iso-A2E

  8. Two-step Purification Method for Aging Pigments A2E and Iso-A2E Using Medium Pressure Liquid Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Il; Park, Sang Cheol [Kyunghee Univ., Seoul (Korea, Republic of); Kim, So Ra; Jang, Young Pyo [Seoul National Univ., Seoul (Korea, Republic of)

    2016-09-15

    A newly modified method for the efficient purification of A2E and iso-A2E using reverse phase silica gel resin with medium pressure liquid chromatography (MPLC) was suggested. MPLC is one of the various preparative column chromatography techniques and separation under pressure renders the use of smaller particle size resins possible and increases the diversity of available stationary phases. A simplified two-step purification method was developed for the purification of aging pigments in eye, A2E and iso-A2E. With simple two-step elution of mobile phase in reverse phase MPLC, A2E and iso-A2E were successfully purified with great efficiency compare with previous column chromatography and HPLC method. This method provides more simple, convenient, cost-effective, and less time-consuming procedure for mass purification of aging pigments A2E and iso-A2E.

  9. Development of an analytical method for separation of phenolic acids by ultra-performance convergence chromatography (UPC2) using a column packed with a sub-2-μm particle.

    Science.gov (United States)

    Jiang, Hai; Yang, Liu; Xing, Xudong; Yan, Meiling; Guo, Xinyue; Yang, Bingyou; Wang, Qiu-Hong; Kuang, Hai-Xue

    2018-05-10

    Phenolic acids are important active components of certain Traditional Chinese Medicines (TCM) and have a wide range of biological effects. Separation and purification of phenolic acids remains challenging due to difficulties with quality control using existing chromatographic methods The purpose of this study was to compare the effects of different chromatographic columns and conditions for the separation of phenolic acids. The BEH column was determined to be optimal, providing efficient separation in the shortest time (17.00 min) using gradient elution with carbon dioxide as the mobile phase, methanol/acetonitrile (70:30, v/v) with 1% TFA as the modifier, and a flow rate of 0.8 mL/min. Good peak shapes were obtained, and the peak asymmetry values were close to 1.00 for all phenolic acids. The resolution was more than 2.83 for all separated peaks. The developed method was subsequently applied to the determination of phenolic acids in Xanthii Fructus. These results are beneficial for quality control and standardization of herbal drugs using UPC 2 , providing an efficient, rapid and environmentally friendly scientific basis for future analysis of phenolic acids. Copyright © 2018. Published by Elsevier B.V.

  10. Development and validation of a high-performance liquid chromatography-tandem mass spectrometry method for the simultaneous determination of irinotecan and its main metabolites in human plasma and its application in a clinical pharmacokinetic study.

    Directory of Open Access Journals (Sweden)

    Elena Marangon

    Full Text Available Irinotecan is currently used in several cancer regimens mainly in colorectal cancer (CRC. This drug has a narrow therapeutic range and treatment can lead to side effects, mainly neutropenia and diarrhea, frequently requiring discontinuing or lowering the drug dose. A wide inter-individual variability in irinotecan pharmacokinetic parameters and pharmacodynamics has been reported and associated to patients' genetic background. In particular, a polymorphism in the UGT1A1 gene (UGT1A1*28 has been linked to an impaired detoxification of SN-38 (irinotecan active metabolite to SN-38 glucuronide (SN-38G leading to increased toxicities. Therefore, therapeutic drug monitoring of irinotecan, SN-38 and SN-38G is recommended to personalize therapy. In order to quantify simultaneously irinotecan and its main metabolites in patients' plasma, we developed and validated a new, sensitive and specific HPLC-MS/MS method applicable to all irinotecan dosages used in clinic. This method required a small plasma volume, addition of camptothecin as internal standard and simple protein precipitation. Chromatographic separation was done on a Gemini C18 column (3 μM, 100 mm x 2.0 mm using 0.1% acetic acid/bidistilled water and 0.1% acetic acid/acetonitrile as mobile phases. The mass spectrometer worked with electrospray ionization in positive ion mode and selected reaction monitoring. The standard curves were linear (R2 ≥0.9962 over the concentration ranges (10-10000 ng/mL for irinotecan, 1-500 ng/mL for SN-38 and SN-38G and 1-5000 ng/mL for APC and had good back-calculated accuracy and precision. The intra- and inter-day precision and accuracy, determined on three quality control levels for all the analytes, were always <12.3% and between 89.4% and 113.0%, respectively. Moreover, we evaluated this bioanalytical method by re-analysis of incurred samples as an additional measure of assay reproducibility. This method was successfully applied to a pharmacokinetic study in

  11. A simple method for the measurement of radioactivity of samples separated by gas chromatography

    International Nuclear Information System (INIS)

    Farkas, T.

    1981-01-01

    Gas chromatographs with flame ionization detector can be used to determine the radioactivity ( 14 C) of separated peaks. After a suitable change in the detector output the combustion product 14 CO 2 can be trapped by hyamine hydroxyde and measured by liquid scintigraphy. 90% of peak activity can be collected and measured, thus the method can be applied to determine the distribution and specific radioactivity of the components separated by gas chromatography. (author)

  12. Developments in Surrogating Methods

    Directory of Open Access Journals (Sweden)

    Hans van Dormolen

    2005-11-01

    Full Text Available In this paper, I would like to talk about the developments in surrogating methods for preservation. My main focus will be on the technical aspects of preservation surrogates. This means that I will tell you something about my job as Quality Manager Microfilming for the Netherlands’ national preservation program, Metamorfoze, which is coordinated by the National Library. I am responsible for the quality of the preservation microfilms, which are produced for Metamorfoze. Firstly, I will elaborate on developments in preservation methods in relation to the following subjects: · Preservation microfilms · Scanning of preservation microfilms · Preservation scanning · Computer Output Microfilm. In the closing paragraphs of this paper, I would like to tell you something about the methylene blue test. This is an important test for long-term storage of preservation microfilms. Also, I will give you a brief report on the Cellulose Acetate Microfilm Conference that was held in the British Library in London, May 2005.

  13. Simple micellar electrokinetic chromatography method for the determination of hydrogen sulfide in hen tissues.

    Science.gov (United States)

    Kubalczyk, Paweł; Borowczyk, Kamila; Chwatko, Grażyna; Głowacki, Rafał

    2015-04-01

    A new method for the determination of hydrogen sulfide in hen tissues has been developed and validated. For estimation of hydrogen sulfide content, a sample (0.1 g) of hen tissue was treated according to the procedure consisted of some essential steps: simultaneous homogenization of a tissue and derivatization of hydrogen sulfide to its S-quinolinium derivative with 2-chloro-1-methylquinolinium tetrafluoroborate, separation of so-formed derivative by micellar electrokinetic chromatography with sweeping, and detection and quantitation with the use of UV detector set to measure analytical signals at 375 nm. Effective electrophoretic separation was achieved using fused silica capillary (effective length 41.5 cm, 75 μm id) and 0.05 mol/L, pH 8 phosphate buffer with the addition of 0.04 mol/L SDS and 26% ACN. The lower limit of quantification was 0.12 μmol hydrogen sulfide in 1 g of tissue. The calibration curve prepared in tissue homogenate for hydrogen sulfide showed linearity in the range from 0.15 to 2.0 μmol/g, with the coefficient of correlation 0.9978. The relative standard deviation of the points of the calibration curve varied from 8.3 to 3.2% RSD. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Hydroxylapatite chromatography.

    Science.gov (United States)

    Broadhurst, A V

    2001-05-01

    Hydroxylapatite (also called hydroxyapatite), a form of calcium phosphate, can be used as a matrix for the chromatography of both proteins and nucleic acids. Protocols are provided for both standard low-pressure chromatography of a protein mixture using a hydroxylapatite column prepared in the laboratory, and an HPLC method, applicable to proteins and nucleic acids, that uses a commercially available column. Alternate protocols describe column chromatography using a step gradient or batch binding and step-gradient elution.

  15. Methods for separating boron from borated paraffin wax and its determination by ion chromatography

    International Nuclear Information System (INIS)

    Jeyakumar, S.

    2015-01-01

    Boron compounds are found to be useful in shielding against high-energy neutrons. In radiotherapy treatments, in order to protect occupational workers and patients from the undesirable neutron and gamma doses, paraffin wax containing B 4 C/boric acid is used. Low-level borate wastes generated from the nuclear power plants have been immobilized with paraffin wax using a concentrate waste drying system (CWDS). Borated paraffin waxes are prepared by mixing calculated amounts of either boric acid or boron carbide with the molten wax. This necessitates the determination of boron at different locations in order to check the homogeneous distribution of B over the borated wax. The determination of boron in nuclear materials is inevitable due to its high neutron absorption cross section. For the determination of boron in borated waxes, not many methods have been reported. A method based on the pyrohydrolysis extraction of boron and its quantification with ion chromatography was proposed for paraffin waxes borated with H 3 BO 3 and B 4 C. The B 4 C optimum pyrohydrolysis conditions were identified. Wax samples were mixed with U 3 O 8 , which prevents the sample from flare up, and also accelerates the extraction of boron. Pyrohydrolysis was carried out with moist O 2 at 950℃ for 60 and 90 min for wax with H 3 BO 3 and wax with B 4 C, respectively. Two simple methods of separation based on alkali extraction and melting wax in alkali were also developed exclusively for wax with H 3 BO 3 . In all the separations, the recovery of B was above 98%. During IC separation, B was separated as boron-mannitol anion complex. Linear calibration was obtained between 0.1 and 50 ppm of B, and LOD was calculated as 5 ppb (S/N=3). The reproducibility was better than 5% (RSD)

  16. Development and validation of a simple high performance thin layer chromatography method combined with direct 1,1-diphenyl-2-picrylhydrazyl assay to quantify free radical scavenging activity in wine.

    Science.gov (United States)

    Agatonovic-Kustrin, Snezana; Morton, David W; Yusof, Ahmad P

    2016-04-15

    The aim of this study was to: (a) develop a simple, high performance thin layer chromatographic (HPTLC) method combined with direct 1,1-diphenyl-2-picrylhydrazyl (DPPH) assay to rapidly assess and compare free radical scavenging activity or anti-oxidant activity for major classes of polyphenolics present in wines; and (b) to investigate relationship between free radical scavenging activity to the total polyphenolic content (TPC) and total antioxidant capacity (TAC) in the wine samples. The most potent free radical scavengers that we tested for in the wine samples were found to be resveratrol (polyphenolic non-flavonoid) and rutin (flavonoid), while polyphenolic acids (caffeic acid and gallic acid) although present in all wine samples were found to be less potent free radical scavengers. Therefore, the total antioxidant capacity was mostly affected by the presence of resveratrol and rutin, while total polyphenolic content was mostly influenced by the presence of the less potent free radical scavengers gallic and caffeic acids. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Validating a High Performance Liquid Chromatography-Ion Chromatography (HPLC-IC) Method with Conductivity Detection After Chemical Suppression for Water Fluoride Estimation.

    Science.gov (United States)

    Bondu, Joseph Dian; Selvakumar, R; Fleming, Jude Joseph

    2018-01-01

    A variety of methods, including the Ion Selective Electrode (ISE), have been used for estimation of fluoride levels in drinking water. But as these methods suffer many drawbacks, the newer method of IC has replaced many of these methods. The study aimed at (1) validating IC for estimation of fluoride levels in drinking water and (2) to assess drinking water fluoride levels of villages in and around Vellore district using IC. Forty nine paired drinking water samples were measured using ISE and IC method (Metrohm). Water samples from 165 randomly selected villages in and around Vellore district were collected for fluoride estimation over 1 year. Standardization of IC method showed good within run precision, linearity and coefficient of variance with correlation coefficient R 2  = 0.998. The limit of detection was 0.027 ppm and limit of quantification was 0.083 ppm. Among 165 villages, 46.1% of the villages recorded water fluoride levels >1.00 ppm from which 19.4% had levels ranging from 1 to 1.5 ppm, 10.9% had recorded levels 1.5-2 ppm and about 12.7% had levels of 2.0-3.0 ppm. Three percent of villages had more than 3.0 ppm fluoride in the water tested. Most (44.42%) of these villages belonged to Jolarpet taluk with moderate to high (0.86-3.56 ppm) water fluoride levels. Ion Chromatography method has been validated and is therefore a reliable method in assessment of fluoride levels in the drinking water. While the residents of Jolarpet taluk (Vellore distict) are found to be at a high risk of developing dental and skeletal fluorosis.

  18. Validation of a high-performance liquid chromatography/fluorescence detection method for the simultaneous quantification of fifteen polycyclic aromatic hydrocarbons

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Olsen, I L; Holst, E

    1991-01-01

    A high-performance liquid chromatography/fluorescence method using multiple wavelength shift for simultaneous quantification of different PAH compounds was developed. The new method was superior to the methods of DONG and GREENBERG [J. Liquid Chromatogr. 11, 1887-1905 (1988)] and WISE et al...... that no systematic errors, and only small unsystematic errors, could be demonstrated. Furthermore, the method had a good reproducibility and a high sensitivity....

  19. Liquid chromatography/tandem mass spectrometry method for quantitative estimation of solutol HS15 and its applications

    OpenAIRE

    Bhaskar, V. Vijaya; Middha, Anil; Srivastava, Pratima; Rajagopal, Sriram

    2015-01-01

    A rapid, sensitive and selective pseudoMRM (pMRM)-based method for the determination of solutol HS15 (SHS15) in rat plasma was developed using liquid chromatography/tandem mass spectrometry (LCâMS/MS). The most abundant ions corresponding to SHS15 free polyethyleneglycol (PEG) oligomers at m/z 481, 525, 569, 613, 657, 701, 745, 789, 833, 877, 921 and 965 were selected for pMRM in electrospray mode of ionization. Purity of the lipophilic and hydrophilic components of SHS15 was estimated using ...

  20. Development of partitioning method

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Dojiri, Shigeru; Kubota, Masumitsu

    1988-10-01

    The literature survey was carried out on the amount of natural resources, behaviors in reprocessing process and in separation and recovery methods of the platinum group elements and technetium which are contained in spent fuel. The essential results are described below. (1) The platinum group elements, which are contained in spent fuel, are quantitatively limited, compared with total demand for them in Japan. And estimated separation and recovery cost is rather high. In spite of that, development of these techniques is considered to be very important because the supply of these elements is almost from foreign resources in Japan. (2) For recovery of these elements, studies of recovery from undisolved residue and from high level liquid waste (HLLW) also seem to be required. (3) As separation and recovery methods, following techniques are considered to be effective; lead extraction, liquid metal extraction, solvent extraction, ion-exchange, adsorption, precipitation, distillation, electrolysis or their combination. (4) But each of these methods has both advantages and disadvantages. So development of such processes largely depends on future works. (author) 94 refs

  1. Development of a two-dimensional high-performance liquid chromatography system coupled with on-line reduction as a new efficient analytical method of 3-nitrobenzanthrone, a potential human carcinogen.

    Science.gov (United States)

    Hasei, Tomohiro; Nakanishi, Haruka; Toda, Yumiko; Watanabe, Tetsushi

    2012-08-31

    3-Nitrobenzanthrone (3-NBA) is an extremely strong mutagen and carcinogen in rats inducing squamous cell carcinoma and adenocarcinoma. We developed a new sensitive analytical method, a two-dimensional HPLC system coupled with on-line reduction, to quantify non-fluorescent 3-NBA as fluorescent 3-aminobenzanthrone (3-ABA). The two-dimensional HPLC system consisted of reversed-phase HPLC and normal-phase HPLC, which were connected with a switch valve. 3-NBA was purified by reversed-phase HPLC and reduced to 3-ABA with a catalyst column, packed with alumina coated with platinum, in ethanol. An alcoholic solvent is necessary for reduction of 3-NBA, but 3-ABA is not fluorescent in the alcoholic solvent. Therefore, 3-ABA was separated from alcohol and impurities by normal-phase HPLC and detected with a fluorescence detector. Extracts from surface soil, airborne particles, classified airborne particles, and incinerator dust were applied to the two-dimensional HPLC system after clean-up with a silica gel column. 3-NBA, detected as 3-ABA, in the extracts was found as a single peak on the chromatograms without any interfering peaks. 3-NBA was detected in 4 incinerator dust samples (n=5). When classified airborne particles, that is, those 7.0 μm in size, were applied to the two-dimensional HPLC system after purified using a silica gel column, 3-NBA was detected in those particles with particle sizes NBA in airborne particles and the detection of 3-NBA in incinerator dust. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. A liquid chromatography-mass spectrometry method for the quantification of bioavailability and bioconversion of beta-carotene to retinol in humans

    NARCIS (Netherlands)

    Yan Wang,; Xiaoying Xu,; Lieshout, van M.; West, C.E.; Lugtenburg, J.; Verhoeven, M.A.; Creemers, A.F.L.

    2000-01-01

    A method based on high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (APCI LC-MS) was developed for the quantification of the bioavailability of retinyl palmitate and -carotene and the bioconversion of -carotene to retinol in humans. Following oral

  3. A new liquid chromatography - tandem mass spectrometry method using atmospheric pressure photo ionization for the simultaneous determination of azaarenes and azaarones in Dutch river sediments

    NARCIS (Netherlands)

    Brulik, J.; Simek, Z.; de Voogt, P.

    2013-01-01

    A new method for the analysis of azaarenes and their degradation products (azaarones) was developed, optimized and validated using liquid chromatography coupled with atmospheric pressure photo ionization tandem mass spectrometric detection (LC-APPI/MS/MS). Seventeen compounds including 4 PAHs

  4. An on-line normal-phase high performance liquid chromatography method for the rapid detection of radical scavengers in non-polar food matrixes

    NARCIS (Netherlands)

    Zhang, Q.; Klift, van der E.J.C.; Janssen, H.G.; Beek, van T.A.

    2009-01-01

    An on-line method for the rapid pinpointing of radical scavengers in non-polar mixtures like vegetable oils was developed. To avoid problems with dissolving the sample, normal-phase chromatography on bare silica gel was used with mixtures of hexane and methyl tert-butyl ether as the eluent. The high

  5. Cross validation of gas chromatography-flame photometric detection and gas chromatography-mass spectrometry methods for measuring dialkylphosphate metabolites of organophosphate pesticides in human urine.

    Science.gov (United States)

    Prapamontol, Tippawan; Sutan, Kunrunya; Laoyang, Sompong; Hongsibsong, Surat; Lee, Grace; Yano, Yukiko; Hunter, Ronald Elton; Ryan, P Barry; Barr, Dana Boyd; Panuwet, Parinya

    2014-01-01

    We report two analytical methods for the measurement of dialkylphosphate (DAP) metabolites of organophosphate pesticides in human urine. These methods were independently developed/modified and implemented in two separate laboratories and cross validated. The aim was to develop simple, cost effective, and reliable methods that could use available resources and sample matrices in Thailand and the United States. While several methods already exist, we found that direct application of these methods required modification of sample preparation and chromatographic conditions to render accurate, reliable data. The problems encountered with existing methods were attributable to urinary matrix interferences, and differences in the pH of urine samples and reagents used during the extraction and derivatization processes. Thus, we provide information on key parameters that require attention during method modification and execution that affect the ruggedness of the methods. The methods presented here employ gas chromatography (GC) coupled with either flame photometric detection (FPD) or electron impact ionization-mass spectrometry (EI-MS) with isotopic dilution quantification. The limits of detection were reported from 0.10ng/mL urine to 2.5ng/mL urine (for GC-FPD), while the limits of quantification were reported from 0.25ng/mL urine to 2.5ng/mL urine (for GC-MS), for all six common DAP metabolites (i.e., dimethylphosphate, dimethylthiophosphate, dimethyldithiophosphate, diethylphosphate, diethylthiophosphate, and diethyldithiophosphate). Each method showed a relative recovery range of 94-119% (for GC-FPD) and 92-103% (for GC-MS), and relative standard deviations (RSD) of less than 20%. Cross-validation was performed on the same set of urine samples (n=46) collected from pregnant women residing in the agricultural areas of northern Thailand. The results from split sample analysis from both laboratories agreed well for each metabolite, suggesting that each method can produce

  6. Validation of a method to determine methylmercury in fish tissues using gas chromatography

    International Nuclear Information System (INIS)

    Vega Bolannos, Luisa O.; Arias Verdes, Jose A.; Beltran Llerandi, Gilberto; Castro Diaz, Odalys; Moreno Tellez, Olga L.

    2000-01-01

    We validated a method to determine methylmercury in fish tissues using gas chromatography with an electron capture detector as described by the Association of Official Analytical Chemist (AOAC) International. The linear curve range was 0.02 to 1 g/ml and linear correlation coefficient was 0.9979. A 1 mg/kg methylmercury-contaminated fish sample was analyzed 20 times to determine repeatability of the method. The quantification limit was 0.16 mg/kg and detection limit was 0.06 ppm. Fish samples contaminated with 0.2 to 10 mg/kg methylmercury showed recovery indexes from 94.66 to 108.8%

  7. Comparison of photoacoustic radiometry to gas chromatography/mass spectrometry methods for monitoring chlorinated hydrocarbons

    International Nuclear Information System (INIS)

    Sollid, J.E.; Trujillo, V.L.; Limback, S.P.; Woloshun, K.A.

    1996-01-01

    A comparison of two methods of gas chromatography mass spectrometry (GCMS) and a nondispersive infrared technique, photoacoustic radiometry (PAR), is presented in the context of field monitoring a disposal site. First is presented an historical account describing the site and early monitoring to provide an overview. The intent and nature of the monitoring program changed when it was proposed to expand the Radiological Waste Site close to the Hazardous Waste Site. Both the sampling methods and analysis techniques were refined in the course of this exercise

  8. Development and validation of reverse phase high performance liquid chromatography for citral analysis from essential oils.

    Science.gov (United States)

    Gaonkar, Roopa; Yallappa, S; Dhananjaya, B L; Hegde, Gurumurthy

    2016-11-15

    Citral is a widely used monoterpene aldehyde in aromatherapy, food and pesticide industries. A new validated reverse phase high performance liquid chromatography (RP - HPLC) procedure for the detection and quantification of cis-trans isomers of citral was developed. The RP-HPLC analysis was carried out using Enable C - 18G column (250×4.6mm, 5μ), with acetonitrile and water (70: 30) mobile phase in isocratic mode at 1mL/min flow. A photodiode array (PDA) detector was set at 233nm for the detection of citral. The method showed linearity, selectivity and accuracy for citral in the range of 3-100μg/mL. In order to compare the new RP-HPLC method with the available methods, one of the commercially available essential oil from Cymbopogon flexuosus was analyzed using new RP-HPLC method and the same was analyzed using GC-MS for the comparison of the method for the detection of citral. The GC-MS analysis was done using mass selective detector (MSD) showed citral content to be of 72.76%; wherein the new method showed to contain that same at 74.98%. To prove the application of the new method, essential oils were extracted from lemongrass, lemon leaves and mosambi peels by steam distillation. The citral content present in the essential and also in the condensate was analyzed. The method was found to be suitable for the analysis of citral in essential oils and water based citral formulations with a very good resolution of its components geranial and neral. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Contribution of chromatography and hyphenated technology to production process development for pharma chemicals

    International Nuclear Information System (INIS)

    Ueda, Masafumi; Fujii, Yoshimi; Nakamura, Tomokazu

    2010-01-01

    'Chromatography' is an indispensable technique for treating small organic molecules, and 'Hyphenated Technology', which means a combination of two different techniques (in this case, chromatography and mass spectrometry, etc.), is a powerful tool for quick on-line identification of trace amount impurities in processes. During production process development for active pharmaceutical ingredients (APIs) and reactive intermediates, these techniques are mainly utilized for confirmation of synthesized target molecules, by-products and impurities, and also for their identification. This paper describes the contribution of these techniques to process study acceleration and product quality improvement, while showing some examples. (author)

  10. Development of High Performance Thin Layer Chromatography for ...

    African Journals Online (AJOL)

    are likely to be found on the market, especially in developing countries. ... was a deuterium lamp emitting a continuous UV spectrum in the range 200– ... disoproxil fumarate. Table 1. Summary of response function of lamivudine and tenofovir ...

  11. Integrated Graduate and Continuing Education in Protein Chromatography for Bioprocess Development and Scale-Up

    Science.gov (United States)

    Carta, Jungbauer

    2011-01-01

    We describe an intensive course that integrates graduate and continuing education focused on the development and scale-up of chromatography processes used for the recovery and purification of proteins with special emphasis on biotherapeutics. The course includes lectures, laboratories, teamwork, and a design exercise and offers a complete view of…

  12. Method transfer from high-pressure liquid chromatography to ultra-high-pressure liquid chromatography. II. Temperature and pressure effects.

    Science.gov (United States)

    Åsberg, Dennis; Samuelsson, Jörgen; Leśko, Marek; Cavazzini, Alberto; Kaczmarski, Krzysztof; Fornstedt, Torgny

    2015-07-03

    The importance of the generated temperature and pressure gradients in ultra-high-pressure liquid chromatography (UHPLC) are investigated and compared to high-pressure liquid chromatography (HPLC). The drug Omeprazole, together with three other model compounds (with different chemical characteristics, namely uncharged, positively and negatively charged) were used. Calculations of the complete temperature profile in the column at UHPLC conditions showed, in our experiments, a temperature difference between the inlet and outlet of 16 °C and a difference of 2 °C between the column center and the wall. Through van't Hoff plots, this information was used to single out the decrease in retention factor (k) solely due to the temperature gradient. The uncharged solute was least affected by temperature with a decrease in k of about 5% while for charged solutes the effect was more pronounced, with k decreases up to 14%. A pressure increase of 500 bar gave roughly 5% increase in k for the uncharged solute, while omeprazole and the other two charged solutes gave about 25, 20 and 15% increases in k, respectively. The stochastic model of chromatography was applied to estimate the dependence of the average number of adsorption/desorption events (n) and the average time spent by a molecule in the stationary phase (τs) on temperature and pressure on peak shape for the tailing, basic solute. Increasing the temperature yielded an increase in n and decrease in τs which resulted in less skew at high temperatures. With increasing pressure, the stochastic modeling gave interesting results for the basic solute showing that the skew of the peak increased with pressure. The conclusion is that pressure effects are more pronounced for both retention and peak shape than the temperature effects for the polar or charged compounds in our study. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Chemistry and liquid chromatography methods for the analyses of primary oxidation products of triacylglycerols.

    Science.gov (United States)

    Zeb, A

    2015-05-01

    Triacylglycerols (TAGs) are one of the major components of the cells in higher biological systems, which can act as an energy reservoir in the living cells. The unsaturated fatty acid moiety is the key site of oxidation and formation of oxidation compounds. The TAG free radical generates several primary oxidation compounds. These include hydroperoxides, hydroxides, epidioxides, hydroperoxy epidioxides, hydroxyl epidioxides, and epoxides. The presence of these oxidized TAGs in the cell increases the chances of several detrimental processes. For this purpose, several liquid chromatography (LC) methods were reported in their analyses. This review is therefore focused on the chemistry, oxidation, extraction, and the LC methods reported in the analyses of oxidized TAGs. The studies on thin-layer chromatography were mostly focused on the total oxidized TAGs separation and employ hexane as major solvent. High-performance LC (HPLC) methods were discussed in details along with their merits and demerits. It was found that most of the HPLC methods employed isocratic elution with methanol and acetonitrile as major solvents with an ultraviolet detector. The coupling of HPLC with mass spectrometry (MS) highly increases the efficiency of analysis as well as enables reliable structural elucidation. The use of MS was found to be helpful in studying the oxidation chemistry of TAGs and needs to be extended to the complex biological systems.

  14. A single-run liquid chromatography mass spectrometry method to quantify neuroactive kynurenine pathway metabolites in rat plasma.

    Science.gov (United States)

    Orsatti, Laura; Speziale, Roberto; Orsale, Maria Vittoria; Caretti, Fulvia; Veneziano, Maria; Zini, Matteo; Monteagudo, Edith; Lyons, Kathryn; Beconi, Maria; Chan, Kelvin; Herbst, Todd; Toledo-Sherman, Leticia; Munoz-Sanjuan, Ignacio; Bonelli, Fabio; Dominguez, Celia

    2015-03-25

    Neuroactive metabolites in the kynurenine pathway of tryptophan catabolism are associated with neurodegenerative disorders. Tryptophan is transported across the blood-brain barrier and converted via the kynurenine pathway to N-formyl-L-kynurenine, which is further degraded to L-kynurenine. This metabolite can then generate a group of metabolites called kynurenines, most of which have neuroactive properties. The association of tryptophan catabolic pathway alterations with various central nervous system (CNS) pathologies has raised interest in analytical methods to accurately quantify kynurenines in body fluids. We here describe a rapid and sensitive reverse-phase HPLC-MS/MS method to quantify L-kynurenine (KYN), kynurenic acid (KYNA), 3-hydroxy-L-kynurenine (3HK) and anthranilic acid (AA) in rat plasma. Our goal was to quantify these metabolites in a single run; given their different physico-chemical properties, major efforts were devoted to develop a chromatography suitable for all metabolites that involves plasma protein precipitation with acetonitrile followed by chromatographic separation by C18 RP chromatography, detected by electrospray mass spectrometry. Quantitation range was 0.098-100 ng/ml for 3HK, 9.8-20,000 ng/ml for KYN, 0.49-1000 ng/ml for KYNA and AA. The method was linear (r>0.9963) and validation parameters were within acceptance range (calibration standards and QC accuracy within ±30%). Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Hydrophilic Interaction Liquid Chromatography/Mass Spectrometry: An Attractive and Prospective Method for the Quantitative Bioanalysis in Drug Metabolism.

    Science.gov (United States)

    Li, Zheng; Han, Jie; Sun, Shi-an; Chen, Kai; Tang, Dao-quan

    2016-01-01

    During the development, dosage optimization and safety evaluation of a drug, rapid and precise monitoring of administered drug and/or its metabolites in biological samples including blood, plasma, serum, tissues and saliva are vital. As drug biotransformation produces more hydrophilic metabolites for the enhancement of drug elimination, which is often a challenge for traditional reversed-phase liquid chromatography (RPLC) separation. Because hydrophilic interaction liquid chromatography (HILIC) is capable of retaining polar compounds and readily compatible with mass spectrometry (MS), HILIC has been used as a complementary separation technique to RPLC for analysis of polar metabolites, especially polar drugs and their metabolites. This review covers core aspects of HILIC-MS/MS method and overall profile of its application in analysis of drug and/or its metabolites. The emphasis of this paper has been placed on the applications of HILIC-MS/MS method in quantitative bioanalysis of drugs alone or along with their metabolites in drug metabolism studies in recent years. As a fundamental and critical step of bioanalytical method, conventional sample preparation techniques of biological matrices for the HILIC-MS/MS analysis of drugs and/or their metabolites are also briefly featured.

  16. An optimized method for fatty acid analysis, including quantification of trans fatty acids, in human adipose tissue by gas-liquid chromatography

    DEFF Research Database (Denmark)

    Bysted, Anette; Cold, S; Hølmer, Gunhild Kofoed

    1999-01-01

    Considering the need for a quick direct method for measurement of the fatty acid composition including trans isomers ofhuman adipose tissue we have developed a procedure using gas-liquid chromatography (GLC) alone, which is thussuitable for validation of fatty acid status in epidemiological studies...... for 25 min, and finally raised at 25 degrees C/min to 225 degrees C. The trans and cis isomers of18:1 were well separated from each other, as shown by silver-ion thin-layer chromatography. Verification by standardsshowed that the trans 18:1 isomers with a double bond in position 12 or lower were...

  17. Simultaneous separation of antihyperlipidemic drugs by green ultrahigh-performance liquid chromatography-diode array detector method: Improving the health of liquid chromatography.

    Science.gov (United States)

    Alghazi, Mansoor; Alanazi, Fars; Mohsin, Kazi; Siddiqui, Nasir Ali; Shakeel, Faiyaz; Haq, Nazrul

    2017-04-01

    Statins in combination with fibrates show beneficial effects on the lipoprotein profile of patients because they have positive complimentary effects on lipid profile. A new green ultrahigh-performance liquid chromatography-diode array detector method for simultaneous analysis of simvastatin (SMV) and fenofibrate (FNF) in standard form, marketed formulations, and self-emulsifying drug delivery system formulations was developed and validated in the present investigation. The method utilized C 18 as stationary phase and a combination of methanol:water (8:2) as an eluent. It was found that selected eluent provided short run time (2.5 minutes), better peak symmetry and satisfactory values of other chromatographic parameters such as resolution (Rs=2.325), capacity factor (k, 3.0 and 4.2 for SMV and FNF, respectively), selectivity (α =1.4), and number of theoretical plates (N, 4265 and 5285 for SMV and FNF, respectively). An excellent linear relationship (r 2 0.998 and 0.997 for SMV and FNF, respectively) was observed for linear regression data for the calibration plots. The developed system was validated for accuracy, precision, robustness (˃ 2% for both drugs) and recovery (98-102% for both drugs). Results obtained from the statistical treatment of the values obtained for different parameters proved that the method is suitable, reproducible, and selective for the simultaneous analysis of SMV and FNF in bulk, marketed, and self-emulsifying drug delivery system formulations. The replacement of commonly applied toxic solvents with innocuous and environmentally benign solvents provides a better option than the more toxic processes in drug analysis. Copyright © 2016. Published by Elsevier B.V.

  18. Development and validation of a solid-phase extraction method coupled to liquid chromatography with fluorescence detection for the determination of fluoroquinolone residues in powdered infant formulae. Application to the analysis of samples from the Spanish and Latin American market.

    Science.gov (United States)

    Rodriguez, E; Moreno-Bondi, M C; Marazuela, M D

    2008-10-31

    This paper describes a new method for the effective extraction, clean-up and chromatographic analysis of residues of four fluoroquinolones (ciprofloxacin, enrofloxacin, danofloxacin and sarafloxacin) in powdered infant formulae and follow-on preparations. Samples were reconstituted following the manufacturer's recommendations and treated with trichloroacetic acid in methanol 10% (w/v) for deproteinization. Two solid-phase extraction cartridges have been evaluated for sample clean-up and preconcentration, Strata Screen A and Strata X and the later provided the best recoveries for all the analytes tested. Chromatographic analysis has been carried out using a polar endcapped column (AQUA C(18)) and fluorescence detection, with lomefloxacin (LOME) as internal standard. Method validation has been performed according to European Commission Decision 2002/657/EC criteria, in terms of linearity, recovery, precision, specificity, decision limit (CC(alpha)) and detection capability (CC(beta)). Typical recoveries ranged between 70 and 110% at levels below and above the maximum residue limits of the target analytes in bovine milk, with an excellent intralab reproducibility (RSDsmarket, using LC-MS/MS as confirmatory technique.

  19. Development of a sensitive determination method for benzotriazole UV stabilizers in enviromental water samples with stir bar sorption extraction and liquid desorption prior to ultra-high performance liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Montesdeoca-Esponda, Sarah; del Toro-Moreno, Adrián; Sosa-Ferrera, Zoraida; Santana-Rodríguez, José Juan

    2013-07-01

    Benzotriazole UV stabilizers are emerging compounds used in personal care products and can enter surface water after passing through wastewater treatment plants without being removed. Because these analytes are strongly hydrophobic, there is an environmental risk of accumulation in solid matrices and magnification through the trophic chain. In this work, a method based on stir bar sorption extraction with liquid desorption is presented for the extraction of benzotriazole UV stabilizers from water samples. Stir bar sorptive extraction was combined with ultra-high performance LC with MS/MS detection. All important factors affecting the stir bar sorptive extraction procedure are discussed, and the optimized method was applied to seawater and wastewater samples from Gran Canaria Island, providing good selectivity and sensitivity with LODs and limits of quantification in the range of 18.4-55.1 and 61.5-184 ng/L, respectively. Recoveries between 68.4-92.2% were achieved for the more polar compounds, whereas the recoveries were lower for the two less polar compounds, most likely due to their strong absorption into the polydimethylsiloxane stir bar phase that does not allows the complete desorption. The repeatability studies gave RSDs of between 6.45 and 12.6% for all compounds in the real samples. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Simplified and rapid method for extraction of ergosterol from natural samples and detection with quantitative and semi-quantitative methods using thin-layer chromatography

    OpenAIRE

    Larsen, Cand.scient Thomas; Ravn, Senior scientist Helle; Axelsen, Senior Scientist Jørgen

    2004-01-01

    A new and simplified method for extraction of ergosterol (ergoste-5,7,22-trien-3-beta-ol) from fungi in soil and litter was developed using pre-soaking extraction and paraffin oil for recovery. Recoveries of ergosterol were in the range of 94 - 100% depending on the solvent to oil ratio. Extraction efficiencies equal to heat-assisted extraction treatments were obtained with pre-soaked extraction. Ergosterol was detected with thin-layer chromatography (TLC) using fluorodensitometry with a quan...

  1. Development and validation of a method for the analysis of Ochratoxin A in roasted coffee by liquid chromatography/electrospray-mass spectrometry in Tandem (LC/ESI-MS/MS

    Directory of Open Access Journals (Sweden)

    Raquel D. C. C. Bandeira

    2012-01-01

    Full Text Available A method using LC/ESI-MS/MS for the quantitative analysis of Ochratoxin A in roasted coffee was described. Linearity was demonstrated (r = 0.9175. The limits of detection and quantification were 1.0 and 3.0 ng g-1, respectively. Trueness, repeatability and intermediate precision values were 89.0-108.8%; 2.4-13.7%; 12.5-17.8%, respectively. To the best of our knowledge, this is the first report in which Ochratoxin A in roasted coffee is analysed by LC/ESI-MS/MS, contributing to the field of mycotoxin analysis, and it will be used for future production of Certified Reference Material.

  2. Development of an ultra-fast liquid chromatography-tandem mass spectrometry method for simultaneous determination of seven flavonoids in rat plasma: Application to a comparative pharmacokinetic investigation of Ginkgo biloba extract and single pure ginkgo flavonoids after oral administration.

    Science.gov (United States)

    Wang, Tianyang; Xiao, Jie; Hou, Huiping; Li, Pei; Yuan, Ziyue; Xu, Huarong; Liu, Ran; Li, Qing; Bi, Kaishun

    2017-08-15

    For deeper pharmacokinetic investigation and further curative application of ginkgo flavonoids, a delicate, efficient and precise UFLC-MS/MS technique for synchronous quantitation of seven flavonoids, apigenin, luteolin, naringenin, quercetin, diosmetin, kaempferol and isorhamnetin in rat plasma has been established. After mixing with the internal standard (IS) linarin, bio-samples were pretreated via ethyl acetate for liquid-liquid extraction, then isolated at 0.2ml/min flow rate on a Venusil MP C 18 chromatographic column (100mm×2.1mm, 3μm) by means of gradient elution. 0.1% formic acid-water and methanol system was used as the mobile phase. Mass spectrometric inspection was conducted on a 4000Q UFLC-MS/MS system with turbo ion spray source in patterns of negative ion and multiple reaction-monitoring (MRM). All calibration curves proved favorable linearity (R 2 ≥0.9918) in linear ranges. Intra-day and inter-day precisions didn't exceed 14.0% for all the analytes, and the accuracy was within 6.9%. Extraction recoveries of analytes and IS were less than ±15.0% of nominal concentrations. This method has been under thorough and firm verification for a comparative pharmacokinetic research after gavage between Ginkgo biloba extract and single pure ginkgo flavonoids. The results demonstrated that there're evident pharmacokinetic discrepancies, and possible structural influences were innovatively proposed. Generally, substitution with 3-hydroxylation, a double bond in ring C, ring B methoxylation often confer longer onset period. The existence of ring B catechol group gives rise to faster clearance. Copyright © 2017. Published by Elsevier B.V.

  3. A sediment extraction and cleanup method for wide-scope multitarget screening by liquid chromatography-high-resolution mass spectrometry.

    Science.gov (United States)

    Massei, Riccardo; Byers, Harry; Beckers, Liza-Marie; Prothmann, Jens; Brack, Werner; Schulze, Tobias; Krauss, Martin

    2018-01-01

    Previous studies on organic sediment contaminants focused mainly on a limited number of highly hydrophobic micropollutants accessible to gas chromatography using nonpolar, aprotic extraction solvents. The development of liquid chromatography-high-resolution mass spectrometry (LC-HRMS) permits the spectrum of analysis to be expanded to a wider range of more polar and ionic compounds present in sediments and allows target, suspect, and nontarget screening to be conducted with high sensitivity and selectivity. In this study, we propose a comprehensive multitarget extraction and sample preparation method for characterization of sediment pollution covering a broad range of physicochemical properties that is suitable for LC-HRMS screening analysis. We optimized pressurized liquid extraction, cleanup, and sample dilution for a target list of 310 compounds. Finally, the method was tested on sediment samples from a small river and its tributaries. The results show that the combination of 100 °C for ethyl acetate-acetone (50:50, neutral extract) followed by 80 °C for acetone-formic acid (100:1, acidic extract) and methanol-10 mM sodium tetraborate in water (90:10, basic extract) offered the best extraction recoveries for 287 of 310 compounds. At a spiking level of 1 μg mL -1 , we obtained satisfactory cleanup recoveries for the neutral extract-(93 ± 23)%-and for the combined acidic/basic extracts-(42 ± 16)%-after solvent exchange. Among the 69 compounds detected in environmental samples, we successfully quantified several pharmaceuticals and polar pesticides.

  4. Development of headspace solid-phase microextraction method for ...

    African Journals Online (AJOL)

    A headspace solid-phase microextraction (HS-SPME) method was developed as a preliminary investigation using univariate approach for the analysis of 14 multiclass pesticide residues in fruits and vegetable samples. The gas chromatography mass spectrometry parameters (desorption temperature and time, column flow ...

  5. Main Achievements 2003-2004 - Interdisciplinary Research - Radiation detection methods for health, earth and environmental sciences - Detection methods in gas chromatography

    International Nuclear Information System (INIS)

    2005-01-01

    Detection methods in gas chromatography are under development, especially ultra-sensitive gas chromatography detection methods to monitor the atmosphere (with respect to gases active in the destruction of the Earth ozone layer). A new chromatographic method has been elaborated for Ne determination, and technique for determination of Ar and N 2 in groundwater has been significantly improved. Measurements of neon are performed by means of a chromatographic system equipped with a helium ionization detector (PD-HID) doped with neon pulse discharge, working with a modified sample introduction system. The Ar and N 2 contents are determined by a thermal-conductivity detector (TCD). The problem of separation of Ar from O 2 has been solved by catalytic removal of the latter from the sample. The measurement reproducibility is 1%, 2% and 0.5% for Ar, Ne and N 2 , respectively. Both methods were successfully applied in measurements of groundwaters in the Cracow area. The excess air contents are in the range of about 1 to 3 cm 3 STP L-1. The values of recharge temperatures for Holocen water agree reasonably well with the yearly mean long-term surface air temperature (8.2 o C)

  6. Analytical Method Validation of High-Performance Liquid Chromatography and Stability-Indicating Study of Medroxyprogesterone Acetate Intravaginal Sponges

    Directory of Open Access Journals (Sweden)

    Nidal Batrawi

    2017-02-01

    Full Text Available Medroxyprogesterone acetate is widely used in veterinary medicine as intravaginal dosage for the synchronization of breeding cycle in ewes and goats. The main goal of this study was to develop reverse-phase high-performance liquid chromatography method for the quantification of medroxyprogesterone acetate in veterinary vaginal sponges. A single high-performance liquid chromatography/UV isocratic run was used for the analytical assay of the active ingredient medroxyprogesterone. The chromatographic system consisted of a reverse-phase C18 column as the stationary phase and a mixture of 60% acetonitrile and 40% potassium dihydrogen phosphate buffer as the mobile phase; the pH was adjusted to 5.6. The method was validated according to the International Council for Harmonisation (ICH guidelines. Forced degradation studies were also performed to evaluate the stability-indicating properties and specificity of the method. Medroxyprogesterone was eluted at 5.9 minutes. The linearity of the method was confirmed in the range of 0.0576 to 0.1134 mg/mL ( R 2 > 0.999. The limit of quantification was shown to be 3.9 µg/mL. Precision and accuracy ranges were found to be %RSD <0.2 and 98% to 102%, respectively. Medroxyprogesterone capacity factor value of 2.1, tailing factor value of 1.03, and resolution value of 3.9 were obtained in accordance with ICH guidelines. Based on the obtained results, a rapid, precise, accurate, sensitive, and cost-effective analysis procedure was proposed for quantitative determination of medroxyprogesterone in vaginal sponges. This analytical method is the only available method to analyse medroxyprogesterone in veterinary intravaginal dosage form.

  7. Sensitive method for the quantitative determination of bromocriptine in human plasma by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Salvador, Arnaud; Dubreuil, Didier; Denouel, Jannick; Millerioux, L

    2005-06-25

    A sensitive LC-MS-MS assay for the quantitative determination of bromocriptine has been developed and validated and is described in this work. The assay involved the extraction of the analyte from 1 ml of human plasma using a solid phase extraction on Oasis MCX cartridges. Chromatography was performed on a Symmetry C18 (2.1 mm x 100 mm, 3.5 microm) column using a mobile phase consisting of 25:75:01 acetonitrile-water-formic acid with a flow rate of 250 microl/min. The linearity was within the concentration range of 2-500 pg/ml. The lower limit of quantification was 2 pg/ml. This method has been demonstrated to be an improvement over existing methods due to its greater sensitivity and specificity.

  8. Isotope dilution liquid chromatography - mass spectrometry methods for fat- and water-soluble vitamins in nutritional formulations.

    Science.gov (United States)

    Phinney, Karen W; Rimmer, Catherine A; Thomas, Jeanice Brown; Sander, Lane C; Sharpless, Katherine E; Wise, Stephen A

    2011-01-01

    Vitamins are essential to human health, and dietary supplements containing vitamins are widely used by individuals hoping to ensure they have adequate intake of these important nutrients. Measurement of vitamins in nutritional formulations is necessary to monitor regulatory compliance and in studies examining the nutrient intake of specific populations. Liquid chromatographic methods, primarily with UV absorbance detection, are well established for both fat- and water-soluble measurements, but they do have limitations for certain analytes and may suffer from a lack of specificity in complex matrices. Liquid chromatography-mass spectrometry (LC-MS) provides both sensitivity and specificity for the determination of vitamins in these matrices, and simultaneous analysis of multiple vitamins in a single analysis is often possible. In this work, LC-MS methods were developed for both fat- and water-soluble vitamins and applied to the measurement of these analytes in two NIST Standard Reference Materials. When possible, stable isotope labeled internal standards were employed for quantification.

  9. Liquid chromatography tandem mass spectrometry method for simultaneous determination of metoprolol tartrate and ramipril in human plasma.

    Science.gov (United States)

    Gowda, K Veeran; Mandal, Uttam; Senthamil Selvan, P; Sam Solomon, W D; Ghosh, Animesh; Sarkar, Amlan Kanti; Agarwal, Sangita; Nageswar Rao, T; Pal, Tapan Kumar

    2007-10-15

    A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of metoprolol tartrate (MT) and ramipril, in human plasma. Both the drugs were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v). The chromatographic separation was performed on a reversed-phase C8 column with a mobile phase of 10 mM ammonium formate-methanol (3:97, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The method was validated over the concentration range of 5-500 ng/ml for metoprolol and ramipril in human plasma. The precursor to product ion transitions of m/z 268.0-103.10 and m/z 417.20-117.20 were used to measure metoprolol and ramipril, respectively.

  10. A novel liquid chromatography method using diode-array detector for the determination of oleuropein in dietary supplements.

    Science.gov (United States)

    Bertolini, Tiziana; Vicentini, Lorenza; Boschetti, Silvia; Andreatta, Paolo; Gatti, Rita

    2016-09-10

    A simple and fast chromatographic method using ultraviolet diode-array detector (UV-DAD) was developed for the automatic high performance liquid chromatography (HPLC) determination of the title of oleuropein in a new dietary supplements in form of effervescent granules. The chromatographic separations were performed on a C18 core-shell column with detection at λ=232nm. The mobile phase consisted of deionized water with 0.1% TFA and acetonitrile under gradient conditions at a flow-rate of 0.8mL/min. Oleuropein and oleuroside present in the raw material were characterized by high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). The validation of the analytical procedure has been performed determining the following parameters: specificity, linearity, repeatability, reproducibility, accuracy, limit of quantification (LOQ), stability of the standard and sample solutions. Linear response was observed in fortified placebo solutions (determination coefficient: 0.9998). Intra-day precision (relative standard deviation, RSD) was ≤5.0% for peak area and for retention times (tR) without significant differences between intra- and inter-day data. The limits of quantitation (LOQ) was about 5μg/mL and 9pmol/inject. Oleuropein recovery studies gave good results (99.9%) with a R.S.D. of 0.5%. The speed of analysis and the stability of the solutions with a fluctuation Δ (%) ≤2.0 at room temperature means an undoubted advantage of the method allowing the simultaneous preparation of many samples and consecutive chromatographic analyses by using an autosampler. The developed method is suitable for the quality control of oleuropein in raw material and industrial products. The method can be applied in any analytical laboratory not requiring a sophisticated instrumentation. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Validation of a liquid chromatography method for the simultaneous determination of sulfadimethoxine and trimethoprim and application to a stability study.

    Science.gov (United States)

    Louati, K; Mistiri, F; Kallel, M; Safta, F

    2010-03-01

    A liquid chromatography method is described for the simultaneous determination of sulfadimetoxine and trimethoprim from a veterinary formulation at the proportion of 187 mg and 40 mg respectively in presence of some excipient. The solution was subjected to different International Conference On Harmonisation prescribed stress conditions (hydrolysis, oxidation and photolysis). A stability-indicating high-performance liquid chromatography method was developed for the analysis of active substances in presence of their major degradation products. It involved a Knauer Eurospher C18 thermostated column at 25 degrees C, and 9.57 mM phosphate buffer (pH adjusted to 2.0 with orthophosphoric acid)-acetonitrile (70:30 v/v) as mobile phase. The mobile phase flow rate and sample volume injected were 1.2 mL/min and 20 microL, respectively. The selected wavelength for the determination was 248 nm. The method was validated for linearity, precision, accuracy and specificity, and then applied to a stability study of sulfadimetoxine and trimethoprim in the veterinary solution packaged in high density polyethylene plastic bottles of 1 L and 100 mL thermosealed and no thermosealed and corked by a white cap, at both accelerated and long-term conditions required by the International Conference On Harmonisation. The method developed, which separates all of the most degradation products formed under variety of conditions, proved to be simple, accurate, precise and specific. The results of the stress degradation show that the solution is more sensitive to hydrolysis. The stability studies carried out on three batches of each presentation show that the finished product remains stable for six months. Copyright 2010 Elsevier Masson SAS. All rights reserved.

  12. High performance liquid chromatography method for the determination of cinnamyl alcohol dehydrogenase activity in soybean roots.

    Science.gov (United States)

    dos Santos, W D; Ferrarese, Maria de Lourdes Lucio; Ferrarese-Filho, O

    2006-01-01

    This study proposes a simple, quick and reliable method for determining the cinnamyl alcohol dehydrogenase (CAD; EC 1.1.1.195) activity in soybean (Glycine max L. Merr.) roots using reversed-phase high performance liquid chromatography (RP-HPLC). The method includes a single extraction of the tissue and conduction of the enzymatic reaction at 30 degrees C with cinnamaldehydes (coniferyl or sinapyl), substrates of CAD. Disappearance of the substrates in the reaction mixture is monitored at 340 nm (for coniferaldehyde) or 345 nm (for sinapaldehyde) by isocratic elution with methanol/acetic acid through a GLC-ODS (M) column. This HPLC technique furnishes a rapid and reliable measure of cinnamaldehyde substrates, and may be used as an alternative tool to analyze CAD activity in enzyme preparation without previous purification.

  13. Ion-Exchange Membrane Chromatography as an Alternative Method of Separation of Potato y Virus

    Directory of Open Access Journals (Sweden)

    Treder Krzysztof

    2015-12-01

    Full Text Available Procedures of separation of virus particles from a plant material are multistage. Furthermore often they are difficult in terms of methodology and require use of expensive, highly specialist equipment and yield of separation is often low. The antigen obtained is often degraded and contains admixtures of other proteins. Therefore, generation of high quality and specificity antibodies based on such antigen is very difficult and quality of the antibodies has impact on reliability, sensitivity and unambiguity of results of immunodiagnostic tests (e.g. ELISA that are currently conventionally used to detect vegetable viruses. In this study three conventionally-performed methods of separation of potato virus Y (PVY were compared and a method of separation based on membrane chromatography, as an alternative separation technique, has been presented. It has been demonstrated that in proper process conditions good quality virus preparation can be obtained.

  14. Optimization and validation of liquid chromatography and headspace-gas chromatography based methods for the quantitative determination of capsaicinoids, salicylic acid, glycol monosalicylate, methyl salicylate, ethyl salicylate, camphor and l-menthol in a topical formulation.

    Science.gov (United States)

    Pauwels, Jochen; D'Autry, Ward; Van den Bossche, Larissa; Dewever, Cédric; Forier, Michel; Vandenwaeyenberg, Stephanie; Wolfs, Kris; Hoogmartens, Jos; Van Schepdael, Ann; Adams, Erwin

    2012-02-23

    Capsaicinoids, salicylic acid, methyl and ethyl salicylate, glycol monosalicylate, camphor and l-menthol are widely used in topical formulations to relieve local pain. For each separate compound or simple mixtures, quantitative analysis methods are reported. However, for a mixture containing all above mentioned active compounds, no assay methods were found. Due to the differing physicochemical characteristics, two methods were developed and optimized simultaneously. The non-volatile capsaicinoids, salicylic acid and glycol monosalicylate were analyzed with liquid chromatography following liquid-liquid extraction, whereas the volatile compounds were analyzed with static headspace-gas chromatography. For the latter method, liquid paraffin was selected as compatible dilution solvent. The optimized methods were validated in terms of specificity, linearity, accuracy and precision in a range of 80% to 120% of the expected concentrations. For both methods, peaks were well separated without interference of other compounds. Linear relationships were demonstrated with R² values higher than 0.996 for all compounds. Accuracy was assessed by performing replicate recovery experiments with spiked blank samples. Mean recovery values were all between 98% and 102%. Precision was checked at three levels: system repeatability, method precision and intermediate precision. Both methods were found to be acceptably precise at all three levels. Finally, the method was successfully applied to the analysis of some real samples (cutaneous sticks). Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Sample displacement chromatography as a method for purification of proteins and peptides from complex mixtures

    Science.gov (United States)

    Gajdosik, Martina Srajer; Clifton, James; Josic, Djuro

    2012-01-01

    Sample displacement chromatography (SDC) in reversed-phase and ion-exchange modes was introduced approximately twenty years ago. This method takes advantage of relative binding affinities of components in a sample mixture. During loading, there is a competition among different sample components for the sorption on the surface of the stationary phase. SDC was first used for the preparative purification of proteins. Later, it was demonstrated that this kind of chromatography can also be performed in ion-exchange, affinity and hydrophobic-interaction mode. It has also been shown that SDC can be performed on monoliths and membrane-based supports in both analytical and preparative scale. Recently, SDC in ion-exchange and hydrophobic interaction mode was also employed successfully for the removal of trace proteins from monoclonal antibody preparations and for the enrichment of low abundance proteins from human plasma. In this review, the principals of SDC are introduced, and the potential for separation of proteins and peptides in micro-analytical, analytical and preparative scale is discussed. PMID:22520159

  16. Peg Precipitation Coupled with Chromatography is a New and Sufficient Method for the Purification of Botulinum Neurotoxin Type B

    Science.gov (United States)

    Zhao, Yao; Kang, Lin; Gao, Shan; Gao, Xing; Xin, Wenwen; Wang, Jinglin

    2012-01-01

    Clostridium botulinum neurotoxins are used to treat a variety of neuro-muscular disorders, as well as in cosmetology. The increased demand requires efficient methods for the production and purification of these toxins. In this study, a new purification process was developed for purifying type B neurotoxin. The kinetics of C.botulinum strain growth and neurotoxin production were determined for maximum yield of toxin. The neurotoxin was purified by polyethylene glycol (PEG) precipitation and chromatography. Based on design of full factorial experiment, 20% (w/v) PEG-6000, 4°C, pH 5.0 and 0.3 M NaCl were optimal conditions to obtain a high recovery rate of 87% for the type B neurotoxin complex, as indicated by a purification factor of 61.5 fold. Furthermore, residual bacterial cells, impurity proteins and some nucleic acids were removed by PEG precipitation. The following purification of neurotoxin was accomplished by two chromatography techniques using Sephacryl™ S-100 and phenyl HP columns. The neurotoxin was recovered with an overall yield of 21.5% and the purification factor increased to 216.7 fold. In addition, a mouse bioassay determined the purified neurotoxin complex possessed a specific toxicity (LD50) of 4.095 ng/kg. PMID:22761863

  17. A simplified method for rapid quantification of intracellular nucleoside triphosphates by one-dimensional thin-layer chromatography

    DEFF Research Database (Denmark)

    Jendresen, Christian Bille; Kilstrup, Mogens; Martinussen, Jan

    2011-01-01

    -pyrophosphate (PRPP), and inorganic pyrophosphate (PPi) in cell extracts. The method uses one-dimensional thin-layer chromatography (TLC) and radiolabeled biological samples. Nucleotides are resolved at the level of ionic charge in an optimized acidic ammonium formate and chloride solvent, permitting...... quantification of NTPs. The method is significantly simpler and faster than both current two-dimensional methods and high-performance liquid chromatography (HPLC)-based procedures, allowing a higher throughput while common sources of inaccuracies and technical problems are avoided. For determination of PPi...

  18. Validation of ascorbic acid tablets of national production by igh-performance liquid chromatography method

    International Nuclear Information System (INIS)

    Rodriguez Hernandez, Yaslenis; Suarez Perez, Yania; Izquierdo Castro, Idalberto

    2009-01-01

    We validate an analytical method by high-performance liquid chromatography to determine ascorbic acid proportion in vitamin C tablets, which was designed as an alternative method to quality control and to follow-up of active principle chemical stability, since official techniques to quality control of ascorbic acid in tablets are not selective with degradation products. Method was modified according to that reported in USP 28, 2005 for analysis of injectable product. We used a RP-18 column of 250 x 4.6 mm 5 μm with a UV detector to 245 nm. Its validation was necessary for both objectives, considering parameters required for methods of I and II categories. This method was enough linear, exact, and precise in the rank of 100-300 μg/mL. Also, it was selective with remaining components of matrix and with the possible degradation products achieved in stressing conditions. Detection and quantification limits were estimated. When method was validated it was applied to ascorbic acid quantification in two batches of expired tablets and we detected a marked influence of container in active degradation principle after 12 months at room temperature. (Author)

  19. Isotope-dilution gas chromatography-mass spectrometry method for the analysis of hydroxyurea.

    Science.gov (United States)

    Garg, Uttam; Scott, David; Frazee, Clint; Kearns, Gregory; Neville, Kathleen

    2015-06-01

    Hydroxyurea is used in the treatment of various malignancies and sickle cell disease. There are limited studies on the pharmacokinetics of hydroxyurea, particularly in pediatric patients. An accurate, precise, and sensitive method is needed to support such studies and to monitor therapeutic adherence. We describe a novel gas chromatography-mass spectrometry (GC-MS) method for the determination of hydroxyurea concentration in plasma using stable labeled hydroxyurea C N2 as an internal standard. The method involved an organic extraction followed by the preparation of trimethylsilyl (TMS) derivatives of hydroxyurea for GC-MS selected ion-monitoring analysis. The following mass-to-charge (m/z) ratio ions for silated hydroxyurea and hydroxyurea C N2 were monitored: hydroxyurea-quantitative ion 277, qualifier ions 292 and 249; hydroxyurea C N2-quantitative ion 280, qualifier ion 295. This method was evaluated for reportable range, accuracy, within-run and between-run imprecisions, and limits of quantification. The reportable range for the method was 0.1-100 mcg/mL. All results were accurate within an allowable error of 15%. Within-run and between-run imprecisions were hydroxyurea described here is accurate, sensitive, precise, and robust. Its characteristics make the method suitable for supporting pharmacokinetic studies and/or clinical therapeutic monitoring.

  20. High-performance liquid chromatography method validation for determination of tetracycline residues in poultry meat

    Directory of Open Access Journals (Sweden)

    Vikas Gupta

    2014-01-01

    Full Text Available Background: In this study, a method for determination of tetracycline (TC residues in poultry with the help of high-performance liquid chromatography technique was validated. Materials and Methods: The principle step involved in ultrasonic-assisted extraction of TCs from poultry samples by 2 ml of 20% trichloroacetic acid and phosphate buffer (pH 4, which gave a clearer supernatant and high recovery, followed by centrifugation and purification by using 0.22 μm filter paper. Results: Validity study of the method revealed that all obtained calibration curves showed good linearity (r2 > 0.999 over the range of 40-4500 ng. Sensitivity was found to be 1.54 and 1.80 ng for oxytetracycline (OTC and TC. Accuracy was in the range of 87.94-96.20% and 72.40-79.84% for meat. Precision was lower than 10% in all cases indicating that the method can be used as a validated method. Limit of detection was found to be 4.8 and 5.10 ng for OTC and TC, respectively. The corresponding values of limit of quantitation were 11 and 12 ng. Conclusion: The method reliably identifies and quantifies the selected TC and OTC in the reconstituted poultry meat in the low and sub-nanogram range and can be applied in any laboratory.

  1. Development of partitioning method

    International Nuclear Information System (INIS)

    Kondo, Yasuo; Kubota, Masumitsu; Abe, Tadashi; Nagato, Kotaro.

    1991-09-01

    Spent fuels from nuclear power stations contain many useful elements, which can be utilized as heat and irradiation sources, radioisotope, elemental resource, etc. Their recovery from spent fuel and effective uses have the advantages in not only converting the radioactive waste to beneficial resources but also promoting rationalization of the management and disposal of the radioactive wastes. In present study, published literature related to recovery and utilization of useful elements in spent fuel was mainly surveyed, present states and trends in their research and development were analyzed, and their future prospects were conjectured. Research and development on recovery and utilization of useful elements are being continued mainly in USA, Europe and Japan. A transportable food irradiator with Cs-137 and an electric power source with Sr-90 for remote weather station are typical examples in major past applications. However, research and development on recovery and utilization are not so much active and the future efforts should be expected hereafter. Present study was conducted under the auspices of the Science and Technology Agency of Japan. (author)

  2. Analytical method by high resolution-liquid chromatography for assay of 2 g Clonazepam tablets disolution without lactose

    International Nuclear Information System (INIS)

    Garcia Penna, Caridad M; Diego Leon, Rafael; Castinneira Diaz, Mirta; Hernandez Cervera, Mirna; Martinez Espinosa, Vivian

    2007-01-01

    A valid method was developed to assess 2 mg Clonazepam tablets disolution without lactose by high-performance liquid chromatography by UV detection to 254 nm. Establishment of Clonazepam in dissolution medium was confirmed, and parameters of specificity, linearity, and accuracy were assessed, as well as influence of filtration and stability or active principle. Linearity curve was drawed in rank of 1, 2-2,6 μg/mL, with a correlation coefficient similar to 0,99418; statistical test wasn't statistically significant for interceptor and slope. In study, it was possible to demonstrate that stability or active principle in dissolution was maintained in more than double of duration of dissolution assay. (Author)

  3. Development of partitioning method

    International Nuclear Information System (INIS)

    Kobayashi, Tsutomu; Shirahashi, Koichi; Kubota, Masumitsu

    1989-11-01

    Precipitation behavior of elements in a high-level liquid waste (HLW) was studied by using the simulated liquid waste, when the transuranic elements group was precipitated and separated as oxalate from HLW generated from the reprocessing of spent nuclear fuel. The results showed that over 90 % of strontium and barium were precipitated when oxalic acid was directly added to HLW to precipitate the transuranic elements group, and the percentages of these elements precipitated were affected by molybdenum and or zirconium. Therefore, a method of adding oxalic acid into the filtrate was studied after removing previously molybdenum and zirconium as precipitate by denitrating HLW, and it was found that precipitated fractions of strontium and barium could be suppressed about 10 %. Adding oxalic acid under the co-existance of ascorbic acid is effective for quantitative precipitation of neptunium in HLW. In this case, it was found that adding ascorbic acid had little influence on precipitation behavior of the other elements except palladium. (author)

  4. Comprehensive measurement of total nondigestible carbohydrates in foods by enzymatic-gravimetric method and liquid chromatography.

    Science.gov (United States)

    Nishibata, Toyohide; Tashiro, Kouichi; Kanahori, Sumiko; Hashizume, Chieko; Kitagawa, Machiko; Okuma, Kazuhiro; Gordon, Dennis T

    2009-09-09

    Total nondigestible carbohydrate (NDC) in foods was determined by combining, not modifications, AOAC Official Methods 991.43, 2001.03, and 2002.02. Total NDC included insoluble dietary fiber (IDF) + high-molecular-weight soluble dietary fiber (HMWSDF), nondigestible oligosaccharides (NDO) not precipitated in ethanol solution, and resistant starch (RS). Eight sources of NDC (cellulose, wheat bran, gum arabic, resistant maltodextrin, polydextrose, fructooligosaccharide, galactooligosaccharides, and RS) were incorporated in different combinations into standard formula bread samples. All of the NDC sources and bread samples were analyzed for their (1) IDF + HMWSDF content with corrections for residual RS amount using AOAC Official Method 991.43, (2) NDO by liquid chromatography (LC) in AOAC Official Method 2001.03, and (3) RS by AOAC Official Method 2002.02. The correlation coefficient (R(2)) comparing calculated amounts versus measured amounts of total NDC in 11 bread samples was 0.92. Analysis of commercial food samples was also well matched with the DF + NDO value on their nutritional label. Consequently, we confirmed a single measurement of LC can determine all NDO in foods, and total NDC in foods can be determined by unifying existing AOAC Official Methods.

  5. A high-performance liquid chromatography method for the serotonin release assay is equivalent to the radioactive method.

    Science.gov (United States)

    Sono-Koree, N K; Crist, R A; Frank, E L; Rodgers, G M; Smock, K J

    2016-02-01

    The serotonin release assay (SRA) is considered the gold standard laboratory test for heparin-induced thrombocytopenia (HIT). The historic SRA method uses platelets loaded with radiolabeled serotonin to evaluate platelet activation by HIT immune complexes. However, a nonradioactive method is desirable. We report the performance characteristics of a high-performance liquid chromatography (HPLC) SRA method. We validated the performance characteristics of an HPLC-SRA method, including correlation with a reference laboratory using the radioactive method. Serotonin released from reagent platelets was quantified by HPLC using fluorescent detection. Results were expressed as % release and classified as positive, negative, or indeterminate based on previously published cutoffs. Serum samples from 250 subjects with suspected HIT were tested in the HPLC-SRA and with the radioactive method. Concordant classifications were observed in 230 samples (92%). Sera from 41 healthy individuals tested negative. Between-run imprecision studies showed standard deviation of performance characteristics, equivalent to the historic radioactive method, but avoids the complexities of working with radioactivity. © 2015 John Wiley & Sons Ltd.

  6. Development and validation of an ultra-fast and sensitive microflow liquid chromatography-tandem mass spectrometry (MFLC-MS/MS) method for quantification of LSD and its metabolites in plasma and application to a controlled LSD administration study in humans.

    Science.gov (United States)

    Steuer, Andrea E; Poetzsch, Michael; Stock, Lorena; Eisenbeiss, Lisa; Schmid, Yasmin; Liechti, Matthias E; Kraemer, Thomas

    2017-05-01

    Lysergic acid diethylamide (LSD) is a semi-synthetic hallucinogen that has gained popularity as a recreational drug and has been investigated as an adjunct to psychotherapy. Analysis of LSD represents a major challenge in forensic toxicology due to its instability, low drug concentrations, and short detection windows in biological samples. A new, fast, and sensitive microflow liquid chromatography (MFLC) tandem mass spectrometry method for the validated quantification of LSD, iso-LSD, 2-oxo 3-hydroxy-LSD (oxo-HO-LSD), and N-desmethyl-LSD (nor-LSD) was developed in plasma and applied to a controlled pharmacokinetic (PK) study in humans to test whether LSD metabolites would offer for longer detection windows. Five hundred microlitres of plasma were extracted by solid phase extraction. Analysis was performed on a Sciex Eksigent MFLC system coupled to a Sciex 5500 QTrap. The method was validated according to (inter)-national guidelines. MFLC allowed for separation of the mentioned analytes within 3 minutes and limits of quantification of 0.01 ng/mL. Validation criteria were fulfilled for all analytes. PK data could be calculated for LSD, iso-LSD, and oxo-HO-LSD in all participants. Additionally, hydroxy-LSD (HO-LSD) and HO-LSD glucuronide could be qualitatively detected and PK determined in 11 and 8 subjects, respectively. Nor-LSD was only sporadically detected. Elimination half-lives of iso-LSD (median 12 h) and LSD metabolites (median 9, 7.4, 12, and 11 h for oxo-HO-LSD, HO-LSD, HO-LSD-gluc, and nor-LSD, respectively) exceeded those of LSD (median 4.2 h). However, screening for metabolites to increase detection windows in plasma seems not to be constructive due to their very low concentrations. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Separation of pigment formulations by high-performance thin-layer chromatography with automated multiple development.

    Science.gov (United States)

    Stiefel, Constanze; Dietzel, Sylvia; Endress, Marc; Morlock, Gertrud E

    2016-09-02

    Food packaging is designed to provide sufficient protection for the respective filling, legally binding information for the consumers like nutritional facts or filling information, and an attractive appearance to promote the sale. For quality and safety of the package, a regular quality control of the used printing materials is necessary to get consistently good print results, to avoid migration of undesired ink components into the food and to identify potentially faulty ink batches. Analytical approaches, however, have hardly been considered for quality assurance so far due to the lack of robust, suitable methods for the analysis of rarely soluble pigment formulations. Thus, a simple and generic high-performance thin-layer chromatography (HPTLC) method for the separation of different colored pigment formulations was developed on HPTLC plates silica gel 60 by automated multiple development. The gradient system provided a sharp resolution for differently soluble pigment constituents like additives and coating materials. The results of multi-detection allowed a first assignment of the differently detectable bands to particular chemical substance classes (e.g., lipophilic components), enabled the comparison of different commercially available pigment batches and revealed substantial variations in the composition of the batches. Hyphenation of HPTLC with high resolution mass spectrometry and infrared spectroscopy allowed the characterization of single unknown pigment constituents, which may partly be responsible for known quality problems during printing. The newly developed, precise and selective HPTLC method can be used as part of routine quality control for both, incoming pigment batches and monitoring of internal pigment production processes, to secure a consistent pigment composition resulting in consistent ink quality, a faultless print image and safe products. Hyphenation of HPTLC with the A. fischeri bioassay gave first information on the bioactivity or rather

  8. New method for determination of epichlorohydrin in epoxy-coated cans by oxolane derivatization and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Sung, Jun Hyun; Lee, Young Ja; Park, Hyun Jin

    2008-08-01

    A new method was developed for the determination of epichlorohydrin (ECH) in food contact surface of epoxy-coated cans. The oxolane derivative, which produced by reaction of epoxy moiety in ECH with cyclopentanone in the presence of borontrifluoride-diethyletherate, was analyzed by gas chromatography (GC)/mass spectrometry (MS). 1,2-Epoxyhexane was used as internal standard (IS), which produced an oxolane derivative under the same reaction mechanism as ECH. The developed method was validated with 1 ng ml(-1) of limit of detection (LOD, surface area related 20 ng dm(-2)), >0.999 of linearity. Good precision, which was tested both in terms of intra-day repeatability and inter-day reproducibility, and 97.3-102.7% of good recoveries were obtained on three spiked levels of 5.2, 40.3 and 149.1 ng ml(-1). The excellent validation data suggests that this method is more simple, quick and effective than the official method in European Committee for Standardization (CEN) to determine the residual amount of ECH in food contact materials for food law compliance test. The residual amount of ECH for 13 epoxy-coated can samples was analyzed, and none of the samples was found to be detectable levels of ECH in epoxy-coated cans.

  9. A novel high-performance thin layer chromatography method for quantification of long chain aliphatic hydrocarbons from Cissus quadrangularis

    Directory of Open Access Journals (Sweden)

    Vandana Jain

    2016-08-01

    Full Text Available Context: A high-performance thin layer chromatography (HPTLC is an analytical technique, which can be used for the determination of constituents or marker components in various parts of the plants. Earlier studies have estimated phytoconstituents from the stem and other aerial plant parts of Cissus quadrangularis Linn. Estimation of hydrocarbons can also be successfully done using HPTLC technique using suitable derivatization. Aims: To develop and validate a simple and rapid method for the estimation of long chain aliphatic hydrocarbons from the leaves of C. quadrangularis using HPTLC technique. Methods: Precoated silica gel 60 F254 plates were used as stationary phase. The mobile phase used was hexane (100 %. The detection of spots was carried out using berberine sulphate as detecting reagent. Results: The method was validated in terms of linearity, sensitivity, accuracy, and precision. Linearity range was found to be 2-10 µg/mL, limit of detection 0.127 µg/mL, and limit of quantification 0.384 µg/mL. Conclusions: A novel, simple, accurate, precise and sensitive HPTLC method has been developed and validated for the estimation of long chain aliphatic hydrocarbons obtained from the leaves of C. quadrangularis Linn.

  10. Trace Level Determination of Mesityl Oxide and Diacetone Alcohol in Atazanavir Sulfate Drug Substance by a Gas Chromatography Method.

    Science.gov (United States)

    Raju, K V S N; Pavan Kumar, K S R; Siva Krishna, N; Madhava Reddy, P; Sreenivas, N; Kumar Sharma, Hemant; Himabindu, G; Annapurna, N

    2016-01-01

    A capillary gas chromatography method with a short run time, using a flame ionization detector, has been developed for the quantitative determination of trace level analysis of mesityl oxide and diacetone alcohol in the atazanavir sulfate drug substance. The chromatographic method was achieved on a fused silica capillary column coated with 5% diphenyl and 95% dimethyl polysiloxane stationary phase (Rtx-5, 30 m x 0.53 mm x 5.0 µm). The run time was 20 min employing programmed temperature with a split mode (1:5) and was validated for specificity, sensitivity, precision, linearity, and accuracy. The detection and quantitation limits obtained for mesityl oxide and diacetone alcohol were 5 µg/g and 10 µg/g, respectively, for both of the analytes. The method was found to be linear in the range between 10 µg/g and 150 µg/g with a correlation coefficient greater than 0.999, and the average recoveries obtained in atazanavir sulfate were between 102.0% and 103.7%, respectively, for mesityl oxide and diacetone alcohol. The developed method was found to be robust and rugged. The detailed experimental results are discussed in this research paper.

  11. Optimization and validation of high-performance liquid chromatography method for analyzing 25-desacetyl rifampicin in human urine

    Science.gov (United States)

    Lily; Laila, L.; Prasetyo, B. E.

    2018-03-01

    A selective, reproducibility, effective, sensitive, simple and fast High-Performance Liquid Chromatography (HPLC) was developed, optimized and validated to analyze 25-Desacetyl Rifampicin (25-DR) in human urine which is from tuberculosis patient. The separation was performed by HPLC Agilent Technologies with column Agilent Eclipse XDB- Ci8 and amobile phase of 65:35 v/v methanol: 0.01 M sodium phosphate buffer pH 5.2, at 254 nm and flow rate of 0.8ml/min. The mean retention time was 3.016minutes. The method was linear from 2–10μg/ml 25-DR with a correlation coefficient of 0.9978. Standard deviation, relative standard deviation and coefficient variation of 2, 6, 10μg/ml 25-DR were 0-0.0829, 03.1752, 0-0.0317%, respectively. The recovery of 5, 7, 9μg/ml25-DR was 80.8661, 91.3480 and 111.1457%, respectively. Limits of detection (LoD) and quantification (LoQ) were 0.51 and 1.7μg/ml, respectively. The method has fulfilled the validity guidelines of the International Conference on Harmonization (ICH) bioanalytical method which includes parameters of specificity, linearity, precision, accuracy, LoD, and LoQ. The developed method is suitable for pharmacokinetic analysis of various concentrations of 25-DR in human urine.

  12. Binding kinetics of five drugs to beta2-adrenoceptor using peak profiling method and nonlinear chromatography.

    Science.gov (United States)

    Liang, Yuan; Wang, Jing; Fei, Fuhuan; Sun, Huanmei; Liu, Ting; Li, Qian; Zhao, Xinfeng; Zheng, Xiaohui

    2018-02-23

    Investigations of drug-protein interactions have advanced our knowledge of ways to design more rational drugs. In addition to extensive thermodynamic studies, ongoing works are needed to enhance the exploration of drug-protein binding kinetics. In this work, the beta2-adrenoceptor (β 2 -AR) was immobilized on N, N'-carbonyldiimidazole activated amino polystyrene microspheres to prepare an affinity column (4.6 mm × 5.0 cm, 8 μm). The β 2 -AR column was utilized to determine the binding kinetics of five drugs to the receptor. Introducing peak profiling method into this receptor chromatographic analysis, we determined the dissociation rate constants (k d ) of salbutamol, terbutaline, methoxyphenamine, isoprenaline hydrochloride and ephedrine hydrochloride to β 2 -AR to be 15 (±1), 22 (±1), 3.3 (±0.2), 2.3 (±0.2) and 2.1 (±0.1) s -1 , respectively. The employment of nonlinear chromatography (NLC) in this case exhibited the same rank order of k d values for the five drugs bound to β 2 -AR. We confirmed that both the peak profiling method and NLC were capable of routine measurement of receptor-drug binding kinetics. Compared with the peak profiling method, NLC was advantageous in the simultaneous assessment of the kinetic and apparent thermodynamic parameters. It will become a powerful method for high throughput drug-receptor interaction analysis. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Determination of thyroid hormones in mouse tissues by isotope-dilution microflow liquid chromatography-mass spectrometry method.

    Science.gov (United States)

    De Angelis, Meri; Giesert, Florian; Finan, Brian; Clemmensen, Christoffer; Müller, Timo D; Vogt-Weisenhorn, Daniela; Tschöp, Matthias H; Schramm, Karl-Werner

    2016-10-15

    Thyroid hormones (THs) play a critical role in the regulation of many biological processes such as growth, metabolism and development both in humans and wildlife. In general, TH levels are measured by immunoassay (IA) methods but the specificity of the antibodies used in these assays limits selectivity. In the last decade, several analytical methods using liquid chromatography-mass spectrometry (LC-MS) and tandem mass spectrometry (LC-MS/MS) have been developed to measure THs. These new techniques proved to be more accurate than the IA analysis and they were widely used for the determination of TH level in different human and animal tissues. A large part of LC-MS/MS methods described in literature employed between 200 and 500mg of sample, however this quantity can be considered too high especially when preclinical studies are conducted using mice as test subjects. Thus an analytical method that reduces the amount of tissue is essential. In this study, we developed a procedure for the analysis of six THs; L-thyroxine (T4), 3,3',5-triiodo-l-thyronine (T3), 3,3',5'-triiodo-l-thyronine (rT3), 3,5-diiodo-l-thyronine (rT2), 3,3'-diiodo-l-thyronine (T2), 3-iodo-l-thyronine (T1) using isotope ((13)C6-T4, (13)C6-T3, (13)C6-rT3, (13)C6-T2) dilution liquid chromatography-mass spectrometry. The major difference with previously described methods lies in the utilization of a nano-UPLC (Ultra Performance Liquid Chromatography) system in micro configuration. This approach leads to a reduction compared to the published methods, of column internal diameter, flow rate, and injected volume. The result of all these improvements is a decrease in the amount of sample necessary for the analysis. The method was tested on six different mouse tissues: liver, heart, kidney, muscle, lung and brown adipose tissue (BAT). The nano-UPLC system was interfaced with a quadrupole time-of-flight mass spectrometer (Q-TOF2-MS) using the positive ion mode electrospray ionization. In our analytical method

  14. High Performance Thin Layer Chromatography method for analysis of 3,4-methylenedioxymethamphetamine in seized tablets

    Directory of Open Access Journals (Sweden)

    Boris E. Duffau

    2015-12-01

    Full Text Available Context: Consumption of synthetic drugs had increased in recent years, used as a recreational drug by young people who presume that consumption of this drug is harmless for health; however clinical studies have shown that this stimulant and its metabolites are toxic. Due to these reasons, chemical analysis of this illicit drug is crucial from the points of view of occupational medicine, toxicology, and law enforcement with the aim of pursuit the traffic of illegal drug. Aims: Implement and fully validate a rapid and simple method for detection and quantitation of MDMA by High-Performance Thin Layer Chromatography in seized samples. Methods: With the implemented method was analyzed 12 positive samples seized by Chilean police, to found the concentration of MDMA in ecstasy tablets. Results: The method was fully validated, the linearity of the method was evaluated by the calibration curve between 51.0 – 510.0 µg/band (R2 0.9977; limit of detection was 12.1 µg per band, and limit of quantitation was 36.8 µg per band. The precision of the method (RSD was lower than 5.0%. Accuracy was evaluated by determination of the percentage of MDMA recovered by the assay (99.13%, and relative Uncertainty was 6.66%. With this method, it was analyzed real seized samples of MDMA, results showed that all samples contained MDMA and concentration was between 18.15 – 59.84 % w/w. Conclusions: The method is selective, sensitive, and specific, with possible application in forensic analysis. To the best of our knowledge, this is the first report about concentration of MDMA in ecstasy pills in Chile.

  15. Development of a relatively cheap and simple automated separation system for a routine separation procedure based on extraction chromatography

    International Nuclear Information System (INIS)

    Petro Zoriy; Reinhold Flucht; Mechthild Burow; Peter Ostapczuk; Reinhard Lennartz; Myroslav Zoriy

    2010-01-01

    A robust analytical method has been developed in our laboratory for the separation of radionuclides by means of extraction chromatography using an automated separation system. The proposed method is both cheap and simple and provides the advantageous, rapid and accurate separation of the element of interest. The automated separation system enables a shorter separation time by maintaining a constant flow rate of solution and by avoiding clogging or bubbling in the chromatographic column. The present separation method was tested with two types of samples (water and urine) using UTEVA-, TRU- and Sr-specific resins for the separation of U, Th, Am, Pu and Sr. The total separation time for one radionuclide ranged from 60 to 100 min with the separation yield ranging from 68 to 98% depending on the elements separated. We used ICP-QMS, multi-low-level counter and alpha spectroscopy to measure the corresponding elements. (author)

  16. Method for the direct determination of available carbohydrates in low-carbohydrate products using high-performance anion exchange chromatography.

    Science.gov (United States)

    Ellingson, David; Potts, Brian; Anderson, Phillip; Burkhardt, Greg; Ellefson, Wayne; Sullivan, Darryl; Jacobs, Wesley; Ragan, Robert

    2010-01-01

    An improved method for direct determination of available carbohydrates in low-level products has been developed and validated for a low-carbohydrate soy infant formula. The method involves modification of an existing direct determination method to improve specificity, accuracy, detection levels, and run times through a more extensive enzymatic digestion to capture all available (or potentially available) carbohydrates. The digestion hydrolyzes all common sugars, starch, and starch derivatives down to their monosaccharide components, glucose, fructose, and galactose, which are then quantitated by high-performance anion-exchange chromatography with photodiode array detection. Method validation consisted of specificity testing and 10 days of analyzing various spike levels of mixed sugars, maltodextrin, and corn starch. The overall RSD was 4.0% across all sample types, which contained within-day and day-to-day components of 3.6 and 3.4%, respectively. Overall average recovery was 99.4% (n = 10). Average recovery for individual spiked samples ranged from 94.1 to 106% (n = 10). It is expected that the method could be applied to a variety of low-carbohydrate foods and beverages.

  17. The analysis of carbohydrates in milk powder by a new "heart-cutting" two-dimensional liquid chromatography method.

    Science.gov (United States)

    Ma, Jing; Hou, Xiaofang; Zhang, Bing; Wang, Yunan; He, Langchong

    2014-03-01

    In this study, a new"heart-cutting" two-dimensional liquid chromatography method for the simultaneous determination of carbohydrate contents in milk powder was presented. In this two dimensional liquid chromatography system, a Venusil XBP-C4 analysis column was used in the first dimension ((1)D) as a pre-separation column, a ZORBAX carbohydrates analysis column was used in the second dimension ((2)D) as a final-analysis column. The whole process was completed in less than 35min without a particular sample preparation procedure. The capability of the new two dimensional HPLC method was demonstrated in the determination of carbohydrates in various brands of milk powder samples. A conventional one dimensional chromatography method was also proposed. The two proposed methods were both validated in terms of linearity, limits of detection, accuracy and precision. The comparison between the results obtained with the two methods showed that the new and completely automated two dimensional liquid chromatography method is more suitable for milk powder sample because of its online cleanup effect involved. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  18. New ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of irbesartan in human plasma

    Directory of Open Access Journals (Sweden)

    Tanveer A. Wani

    2015-09-01

    Full Text Available With the objective of reducing analysis time and maintaining good efficiency, there has been substantial focus on high-speed chromatographic separations and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS is a preeminent analytical tool for rapid biomedical analysis. In this study a simple, rapid, sensitive, and specific ultra-performance liquid chromatography-MS/MS method was developed and validated for quantification of the angiotensin II receptor antagonist, irbesartan (IRB, in human plasma. After a simple protein precipitation using methanol and acetonitrile, IRB and internal standard (IS telmisartan were separated on Acquity UPLC BEH C18 column (50 mm × 2.1 mm, i.d. 1.7 μm, Waters, Milford, MA, USA using a mobile phase consisted of acetonitrile: methanol: 10 mM ammonium acetate (70: 15: 15 v/v/v with a flow rate of 0.4 mL/min and detected MS/MS in negative ion mode. The ion transitions recorded in multiple reaction monitoring mode were m/z 427.2→193.08 for IRB and m/z 513.2→469.3 for IS. The assay exhibited a linear dynamic range of 2–500 ng/mL for IRB in human plasma with good correlation coefficient of (0.995 and with a lower limit of quantitation of 2 ng/mL. The intra- and interassay precisions were satisfactory; the relative standard deviations did not exceed 9.91%. The proposed UPLC-MS/MS method is simple, rapid, and highly sensitive, and hence it could be reliable for pharmacokinetic and toxicokinetic study in both animals and humans.

  19. Chromium Speciation Analysis by Ion Chromatography Coupled ...

    African Journals Online (AJOL)

    Two methods coupling ion chromatography with inductively coupled plasma - optical emission spectroscopy (ICP-OES) were developed for the simultaneous separation and determination of Cr(III) and Cr(VI) species. In the first method, anion chromatography with sodium bicarbonate/carbonate solution as the eluent was ...

  20. Quantification of the level of fat-soluble vitamins in feed based on the novel microemulsion electrokinetic chromatography (MEEKC) method.

    Science.gov (United States)

    Olędzka, Ilona; Kowalski, Piotr; Bałuch, Alicja; Bączek, Tomasz; Paradziej-Łukowicz, Jolanta; Taciak, Marcin; Pastuszewska, Barbara

    2014-02-01

    Simultaneous quantification of liposoluble vitamins is not a new area of interest, since these compounds co-determine the nutritional quality of food and feed, a field widely explored in the human and animal diet. However, the development of appropriate methods is still a matter of concern, especially when the vitamin composition is highly complex, as is the case with feed designated for laboratory animals, representing a higher health and microbiological status. A method combining microemulsion electrokinetic chromatography (MEEKC) with liquid-liquid extraction was developed for the determination of four fat-soluble vitamins in animal feed. A separation medium consisting of 25 mmol L⁻¹ phosphate buffer (pH 2.5), 2-propanol, 1-butanol, sodium dodecyl sulfate and octane allowed the simultaneous determination of vitamins A, D, E and K within a reasonable time of 25 min. The polarity of the separation voltage was reversed in view of the strongly suppressed electro-osmotic flow, and the applied voltage was set at 12 kV. The fat-soluble vitamins were separated in the order of decreasing hydrophobicity. It was proved that the proposed MEEKC method was sufficiently specific and sensitive for screening fat-soluble vitamins in animal feed samples after their sterilization. © 2013 Society of Chemical Industry.

  1. A High-Performance Thin Layer Chromatography (HPTLC) Method for Simultaneous Determination of Diphenhydramine Hydrochloride and Naproxen Sodium in Tablets.

    Science.gov (United States)

    Bhole, R P; Shinde, S S; Chitlange, S S; Wankhede, S B

    2015-01-01

    A rapid and simple high-performance thin layer chromatography (HPTLC) method with densitometry at 230 nm was developed and validated for simultaneous determination of diphenhydramine hydrochloride (DPH) and naproxen sodium (NPS) from pharmaceutical preparation. The separation was carried out on aluminum plates precoated with silica gel 60 F254 using mobile phase toluene:methanol:glacial acetic acid (7.5:1:0.2, v/v/v). The linearity range lies between 200 and 1200 ng/band for DPH and 1760 and 10,560 ng/band for NPS with correlation coefficients of 0.994 and 0.995, respectively. The R f value for DPH is 0.20 ± 0.05 and for NPS is 0.61 ± 0.06. % Recoveries of DPH and NPS was in the range of 99.70%-99.95% and 99.63%-99.95%, respectively. Limit of detection value for DPH was 13.21 ng/band and for NPS was 8.03 ng/band. Limit of quantitation value for DPH was 40.06 ng/band and for NPS was 24.34 ng/band. The developed method was validated as per ICH guidelines. In stability testing, DPH was found unstable to acid and alkaline hydrolysis, and DPH and NPS were found unstable to oxidation, whereas both the drugs were stable to neutral and photodegradation. The proposed method was successfully applied for the routine quantitative analysis of dosage form containing DPH and NPS.

  2. Optimized and validated high-performance liquid chromatography method for the determination of deoxynivalenol and aflatoxins in cereals.

    Science.gov (United States)

    Skendi, Adriana; Irakli, Maria N; Papageorgiou, Maria D

    2016-04-01

    A simple, sensitive and accurate analytical method was optimized and developed for the determination of deoxynivalenol and aflatoxins in cereals intended for human consumption using high-performance liquid chromatography with diode array and fluorescence detection and a photochemical reactor for enhanced detection. A response surface methodology, using a fractional central composite design, was carried out for optimization of the water percentage at the beginning of the run (X1, 80-90%), the level of acetonitrile at the end of gradient system (X2, 10-20%) with the water percentage fixed at 60%, and the flow rate (X3, 0.8-1.2 mL/min). The studied responses were the chromatographic peak area, the resolution factor and the time of analysis. Optimal chromatographic conditions were: X1 = 80%, X2 = 10%, and X3 = 1 mL/min. Following a double sample extraction with water and a mixture of methanol/water, mycotoxins were rapidly purified by an optimized solid-phase extraction protocol. The optimized method was further validated with respect to linearity (R(2) >0.9991), sensitivity, precision, and recovery (90-112%). The application to 23 commercial cereal samples from Greece showed contamination levels below the legally set limits, except for one maize sample. The main advantages of the developed method are the simplicity of operation and the low cost. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Magnetic solid phase extraction and static headspace gas chromatography-mass spectrometry method for the analysis of polycyclic aromatic hydrocarbons.

    Science.gov (United States)

    Cai, Ying; Yan, Zhihong; Wang, Lijia; NguyenVan, Manh; Cai, Qingyun

    2016-01-15

    A magnetic solid phase extraction (MSPE) protocol combining a static headspace gas chromatography coupled to mass spectrometry (HS-GC-MS) method has been developed for extraction, and determination of 16 polycyclic aromatic hydrocarbons (PAHs) in drinking water samples. Magnetic nanoparticles (MNPs) were coated with 3-aminopropyltriethoxysilane and modified by cholesterol chloroformate. Transmission electron microscope, vibrating sample magnetometer, Fourier transform infrared spectrometry and X-ray photoelectron spectroscopy were used to characterize the cholesterol-functionalized sorbents, and the main parameters affecting the extraction as well as HS sampling, such as sorbent amount, extraction time, oven temperature and equilibration time have been investigated and established. Combination with HS sampling, the MSPE procedure was simple, fast and environmentally friendly, without need of any organic solvent. Method validation proved the feasibility of the developed sorbents for the quantitation of the investigated analytes at trace levels obtaining the limit of detection (S/N=3) ranging from 0.20 to 7.8 ng/L. Good values for intra and inter-day precision were obtained (RSDs ≤ 9.9%). The proposed method was successfully applied to drinking water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. A novel method for analysing key corticosteroids in polar bear (Ursus maritimus) hair using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Weisser, Johan J; Hansen, Martin; Björklund, Erland; Sonne, Christian; Dietz, Rune; Styrishave, Bjarne

    2016-04-01

    This paper presents the development and evaluation of a methodology for extraction, clean-up and analysis of three key corticosteroids (aldosterone, cortisol and corticosterone) in polar bear hair. Such a methodology can be used to monitor stress biomarkers in polar bears and may provide as a useful tool for long-term and retrospective information. We developed a combined pressurized liquid extraction (PLE)-solid phase extraction (SPE) procedure for corticosteroid extraction and clean-up followed by high pressure liquid chromatography tandem mass spectrometry (HPLC-MS/MS) analysis. This procedure allows for the simultaneous determination of multiple steroids, which is in contrast to previous polar bear studies based on ELISA techniques. Absolute method recoveries were 81%, 75% and 60% for cortisol, corticosterone and aldosterone, respectively. We applied the developed method on a hair sample pooled from four East Greenland polar bears. Herein cortisol and corticosterone were successfully determined in levels of 0.32±0.02ng/g hair and 0.13±0.02ng/g hair, respectively. Aldosterone was below limit of detection (LODpolar bears was consistent with cortisol levels previously determined in the Southern Hudson Bay and James Bay in Canada using ELISA kits. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. A high-throughput method for liquid chromatography-tandem mass spectrometry determination of plasma alkylresorcinols, biomarkers of whole grain wheat and rye intake

    DEFF Research Database (Denmark)

    Ross, Alastair B; Svelander, Cecilia; Savolainen, Otto I

    2016-01-01

    supported extraction methods for extracting alkylresorcinols from plasma and improved a normal-phase liquid chromatography coupled to a tandem mass spectrometer method to reduce sample analysis time. The method was validated and compared with gas chromatography-mass spectrometry analysis. Sample preparation...

  6. A quantification method for peroxyacetyl nitrate (PAN) using gas chromatography (GC) with a non-radioactive pulsed discharge detector (PDD)

    Science.gov (United States)

    Zhang, Lei; Jaffe, Daniel A.; Gao, Xin; McClure, Crystal D.

    2018-04-01

    In this study, we developed a method for continuous PAN measurements by gas chromatography (GC) with a non-radioactive pulsed discharge detector (PDD). Operational parameters were optimized based on the ratio of peak height over baseline noise (P/N ratio). The GC/PDD system was compared with a traditional radioactive electron-capture detector (ECD). In the lab, the method detection limit (MDL) of the new GC/PDD method (9 pptv) was lower than the radioactive GC/ECD method (15 pptv), demonstrating its excellent potential. The MDL of GC/PDD in the field campaign at the Mt. Bachelor Observatory (MBO) was 23 pptv, higher than in the lab. This was caused in part by the decreased slope of the calibration curve resulting from the low air pressure level at MBO. However, the MDL level of GC/PDD at MBO is still low enough for accurate PAN measurements, although special attention should be paid to its application at high-elevation sites. Observations of PAN were conducted at MBO in the summer of 2016 with the GC/PDD system, and provided more evidence of the performance of the system. PAN was found to be highly correlated with CO. The promising performance of GC/PDD which does not require a radioactive source makes it a useful approach for accurate PAN measurements in the field.

  7. [Multi-residue method for screening of pesticides in crops by liquid chromatography with tandem mass spectrometry].

    Science.gov (United States)

    Tanizawa, Haruna; Shima, Mikie; Ikehara, Chieko; Kobata, Masakazu; Sato, Motoaki

    2005-10-01

    A simple and rapid method was developed for the screening of 82 pesticides/metabolites in a wide variety of crops, using solid-phase extraction and liquid chromatography with tandem mass spectrometry (LC/MS/MS). After extraction with methanol, the filtered extracts were made up to 100 mL and a 2 mL aliquot was subjected to solid-phase extraction. Co-extractives were removed with a C18 mini-column, while pesticides were retained on 3 kinds of mini-columns (HLB, SAX, activated carbon), and then eluted with acetonitrile. Analysis was performed by LC/MS/MS, and MS acquisition parameters were established in positive and negative ESI modes. The utility of the method was demonstrated by the analysis of 6 crops (carrot, cabbage, onion, spinach, lemon, brown rice) and one mixed vegetable juice. Of 82 compounds tested, 75 in carrot and 62 in lemon were obtained with recoveries ranging from 70-120%. For all samples tested, 75 compounds could be obtained with recoveries of over 50%, and the detection limits of most compounds were lower than 0.01 microg/g. This method provides acceptable performance for analysis of these 75 compounds. Further, by using aliquots of the extracts with small-scale mini-columns, purified samples could be obtained. This proposed method with small matrix effects, is effective and suitable for screening of multiple residual pesticides by using LC/MS/MS.

  8. Screening of extraction methods for glycoproteins from jellyfish ( Rhopilema esculentum) oral-arms by high performance liquid chromatography

    Science.gov (United States)

    Ren, Guoyan; Li, Bafang; Zhao, Xue; Zhuang, Yongliang; Yan, Mingyan; Hou, Hu; Zhang, Xiukun; Chen, Li

    2009-03-01

    In order to select an optimum extraction method for the target glycoprotein (TGP) from jellyfish ( Rhopilema esculentum) oral-arms, a high performance liquid chromatography (HPLC)-assay for the determination of the TGP was developed. Purified target glycoprotein was taken as a standard glycoprotein. The results showed that the calibration curves for peak area plotted against concentration for TGP were linear ( r = 0.9984, y = 4.5895 x+47.601) over concentrations ranging from 50 to 400 mgL-1. The mean extraction recovery was 97.84% (CV2.60%). The fractions containing TGP were isolated from jellyfish ( R. esculentum) oral-arms by four extraction methods: 1) water extraction (WE), 2) phosphate buffer solution (PBS) extraction (PE), 3) ultrasound-assisted water extraction (UA-WE), 4) ultrasound-assisted PBS extraction (UA-PE). The lyophilized extract was dissolved in Milli-Q water and analyzed directly on a short TSK-GEL G4000PWXL (7.8 mm×300 mm) column. Our results indicated that the UA-PE method was the optimum extraction method selected by HPLC.

  9. Rapid method for determination of glyphosate in groundwater using high performance liquid chromatography and solid-phase extraction after derivatization

    Directory of Open Access Journals (Sweden)

    Valdir Eduardo Olivo

    2015-04-01

    Full Text Available The intensive use of pesticides in agriculture has prompted researchers to develop new methods for identifying these pollutants in water. This study sought to validate a high performance liquid chromatography (HPLC method to determine the concentration of the pesticide glyphosate in groundwater samples by using solid-phase extraction (SPE filters after derivatization with chloroformate 9-fluorenylmethoxycarbonyl (FMOC-Cl. For the HPLC method, we evaluated the following main validation parameters: linearity, specificity, precision, accuracy, robustness, and limits of detection and quantification. After validation of the method, we determined the concentration of glyphosate in samples from thirteen deep, tubular wells distributed in urban and rural areas in Chapecó, SC, Brazil. The solvent used in the extraction of excess FMOC-Cl was dichloromethane and subsequently filtration was performed on C18 SPE, and injected into the chromatograph column in amino polymer with fluorescence detection. The analytical curve made in ultrapure water was linear, with a correlation coefficient of 0.99. The limits of detection and quantification were 0.24 and 0.07 µg L-1, respectively. Recovery tests in natural waters ranged from 90.37 to 101.70%. Glyphosate was detected in 5 of the thirteen wells evaluated. The highest concentration of glyphosate (6.80 µg L-1 was detected in a countryside well, near the municipal water supply. Despite the low levels of glyphosate detected in our study, any amount present in groundwater samples is worrisome, as these molecules have low ground mobility.

  10. Quality Evaluation of Potentilla fruticosa L. by High Performance Liquid Chromatography Fingerprinting Associated with Chemometric Methods.

    Science.gov (United States)

    Liu, Wei; Wang, Dongmei; Liu, Jianjun; Li, Dengwu; Yin, Dongxue

    2016-01-01

    The present study was performed to assess the quality of Potentilla fruticosa L. sampled from distinct regions of China using high performance liquid chromatography (HPLC) fingerprinting coupled with a suite of chemometric methods. For this quantitative analysis, the main active phytochemical compositions and the antioxidant activity in P. fruticosa were also investigated. Considering the high percentages and antioxidant activities of phytochemicals, P. fruticosa samples from Kangding, Sichuan were selected as the most valuable raw materials. Similarity analysis (SA) of HPLC fingerprints, hierarchical cluster analysis (HCA), principle component analysis (PCA), and discriminant analysis (DA) were further employed to provide accurate classification and quality estimates of P. fruticosa. Two principal components (PCs) were collected by PCA. PC1 separated samples from Kangding, Sichuan, capturing 57.64% of the variance, whereas PC2 contributed to further separation, capturing 18.97% of the variance. Two kinds of discriminant functions with a 100% discrimination ratio were constructed. The results strongly supported the conclusion that the eight samples from different regions were clustered into three major groups, corresponding with their morphological classification, for which HPLC analysis confirmed the considerable variation in phytochemical compositions and that P. fruticosa samples from Kangding, Sichuan were of high quality. The results of SA, HCA, PCA, and DA were in agreement and performed well for the quality assessment of P. fruticosa. Consequently, HPLC fingerprinting coupled with chemometric techniques provides a highly flexible and reliable method for the quality evaluation of traditional Chinese medicines.

  11. Alternative sorptive extraction method for gas chromatography determination of halogenated anisoles in water and wine samples

    International Nuclear Information System (INIS)

    Montes, R.; Rodriguez, I.; Rubi, E.; Bollain, M.H.; Cela, R.

    2007-01-01

    An alternative sorptive microextraction method for the determination of five halogenated anisoles in water and wine matrices is proposed. Analytes were concentrated in an inexpensive and disposable piece of bulk polydimethylsiloxane (PDMS), desorbed with a small volume of organic solvent, and determined by gas chromatography with electron-capture detection (GC-ECD) or tandem mass spectrometry (GC-MS/MS). The influence of several factors on the efficiency of extraction and desorption steps was investigated in detail and the observed behaviour justified on the basis of thermodynamics and kinetics of the solid-phase microextraction technique. Under optimised conditions, analytes were first extracted in the headspace (HS) mode, at room temperature, for 2.5 h and then desorbed with 1 mL of n-pentane. This extract was further evaporated to 50 μL. The overall extraction yield of the procedure ranged from 40 to 55% and the limits of quantification remained between 0.5 and 20 ng L -1 , depending on the compound considered and the detection technique. Precision and linearity of the method were excellent for all species with both GC-ECD and GC-MS/MS detection. Matrix effects were evaluated with different water and wine samples; moreover, the suitability of the PDMS sorbent for storage of analytes, under different conditions, was demonstrated

  12. Quality Evaluation of Potentilla fruticosa L. by High Performance Liquid Chromatography Fingerprinting Associated with Chemometric Methods

    Science.gov (United States)

    Liu, Wei; Wang, Dongmei; Liu, Jianjun; Li, Dengwu; Yin, Dongxue

    2016-01-01

    The present study was performed to assess the quality of Potentilla fruticosa L. sampled from distinct regions of China using high performance liquid chromatography (HPLC) fingerprinting coupled with a suite of chemometric methods. For this quantitative analysis, the main active phytochemical compositions and the antioxidant activity in P. fruticosa were also investigated. Considering the high percentages and antioxidant activities of phytochemicals, P. fruticosa samples from Kangding, Sichuan were selected as the most valuable raw materials. Similarity analysis (SA) of HPLC fingerprints, hierarchical cluster analysis (HCA), principle component analysis (PCA), and discriminant analysis (DA) were further employed to provide accurate classification and quality estimates of P. fruticosa. Two principal components (PCs) were collected by PCA. PC1 separated samples from Kangding, Sichuan, capturing 57.64% of the variance, whereas PC2 contributed to further separation, capturing 18.97% of the variance. Two kinds of discriminant functions with a 100% discrimination ratio were constructed. The results strongly supported the conclusion that the eight samples from different regions were clustered into three major groups, corresponding with their morphological classification, for which HPLC analysis confirmed the considerable variation in phytochemical compositions and that P. fruticosa samples from Kangding, Sichuan were of high quality. The results of SA, HCA, PCA, and DA were in agreement and performed well for the quality assessment of P. fruticosa. Consequently, HPLC fingerprinting coupled with chemometric techniques provides a highly flexible and reliable method for the quality evaluation of traditional Chinese medicines. PMID:26890416

  13. Alternative sorptive extraction method for gas chromatography determination of halogenated anisoles in water and wine samples

    Energy Technology Data Exchange (ETDEWEB)

    Montes, R. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Instituto de Investigacion y Analisis Alimentario, Universidad de Santiago de Compostela, Santiago de Compostela 15782 (Spain); Rodriguez, I. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Instituto de Investigacion y Analisis Alimentario, Universidad de Santiago de Compostela, Santiago de Compostela 15782 (Spain)], E-mail: qnisaac@usc.es; Rubi, E.; Bollain, M.H.; Cela, R. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Instituto de Investigacion y Analisis Alimentario, Universidad de Santiago de Compostela, Santiago de Compostela 15782 (Spain)

    2007-09-05

    An alternative sorptive microextraction method for the determination of five halogenated anisoles in water and wine matrices is proposed. Analytes were concentrated in an inexpensive and disposable piece of bulk polydimethylsiloxane (PDMS), desorbed with a small volume of organic solvent, and determined by gas chromatography with electron-capture detection (GC-ECD) or tandem mass spectrometry (GC-MS/MS). The influence of several factors on the efficiency of extraction and desorption steps was investigated in detail and the observed behaviour justified on the basis of thermodynamics and kinetics of the solid-phase microextraction technique. Under optimised conditions, analytes were first extracted in the headspace (HS) mode, at room temperature, for 2.5 h and then desorbed with 1 mL of n-pentane. This extract was further evaporated to 50 {mu}L. The overall extraction yield of the procedure ranged from 40 to 55% and the limits of quantification remained between 0.5 and 20 ng L{sup -1}, depending on the compound considered and the detection technique. Precision and linearity of the method were excellent for all species with both GC-ECD and GC-MS/MS detection. Matrix effects were evaluated with different water and wine samples; moreover, the suitability of the PDMS sorbent for storage of analytes, under different conditions, was demonstrated.

  14. Current role of liquid chromatography coupled to mass spectrometry in clinical toxicology screening methods.

    Science.gov (United States)

    Viette, Véronique; Fathi, Marc; Rudaz, Serge; Hochstrasser, Denis; Veuthey, Jean-Luc

    2011-07-01

    Abstract Toxicological screening is the analysis of a biological specimen to detect and identify compounds in patients admitted to the hospital with acute intoxication of unknown origin. The screening of a wide range of toxicologically relevant compounds in biological samples is a serious challenge for clinical laboratories. The high selectivity and sensitivity of liquid chromatography coupled to mass spectrometry or tandem mass spectrometry technology provides an attractive alternative to the current methods. For these reasons, an increasing number of applications for multi-target screening or general screening of unknown compounds in biological matrices are being published. This paper is an overview of sample clean-up, chromatographic separation and mass spectrometry detection procedures which can be combined to obtain screening methods adapted to the constraints and needs of various laboratories, and none specifically in clinical toxicology. Currently the techniques are in the hands of specialists, principally in academic institutes. However, the evolution in technology should allow application of the techniques as a tool in toxicology laboratories and thus more widespread exploitation of their potential.

  15. Improved method for the determination of the cortisol production rate using high-performance liquid chromatography and liquid scintillation counting

    NARCIS (Netherlands)

    van Ingen, H. E.; Endert, E.

    1988-01-01

    Two new methods for the determination of the cortisol production rate using reversed-phase high-performance liquid chromatography are described. One uses ultraviolet detection at 205 nm, the other on-line post-column derivatization with benzamidine, followed by fluorimetric detection. The specific

  16. Calibration of shahid's analytical method for adulterated Zn-edta fertilizers by ion chromatography and atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Khan, M.S.A.; Akram, M.; Qazi, M.A.

    2010-01-01

    Chelated zinc fertilizers are usually recommended in calcareous alkaline soils to provide Zn nutrition in order to prevent possible Zn precipitation. In Punjab (Pakistan), Zn EDTA products are being manufactured, and marketed to meet the zinc requirement of various crops grown in Zn deficient soils. Under fertilizer control order, 1973 (amended), their quality has to be monitored by the Agriculture Department, Government of the Punjab. None of the traditional method was found suitable which can separate the mineral fraction from that of chelated adulterated fertilizer except for those methods based on ion chromatography. Calibration of ion chromatography method was carried out by determining the mineral Zn fraction leading to estimate remaining Zn EDTA fraction in fertilizer samples of adulterated nature i.e. mixture of chelated and mineral fraction. In order to achieve the objective atomic absorption spectroscopy was coupled with ion chromatography. The method offers a specific, reliable technique for determination of chelated zinc in fertilizers. In the first step chelation was broken down with concentrated sulphuric acid treatment and total zinc contents were determined by atomic absorption spectroscopy. In second step, non-chelated (mineral) portion of zinc was determined by ion chromatography using cation column and conductivity detector. Chelated zinc was calculated by subtracting non-chelated (mineral) fraction from total zinc contents. (author)

  17. Determination of methyldibromoglutaronitrile in cosmetic products by high-performance liquid chromatography with electrochemical detection. Method validation

    DEFF Research Database (Denmark)

    Rastogi, Suresh Chandra; Zachariae, Claus; Johansen, Jeanne D

    2004-01-01

    An increased frequency of contact allergy to methyldibromoglutaronitrile (MDBGN), a commonly used preservative in cosmetics and other consumer products, has been reported in recent years. A high-performance liquid chromatography (HPLC) method for the determination of MDBGN in cosmetic products ha...

  18. Determination of methyldibromoglutaronitrile in cosmetic products by high-performance liquid chromatography with electrochemical detection. Method validation

    DEFF Research Database (Denmark)

    Rastogi, Suresh Chandra; Zachariae, Claus; Johansen, Jeanne D

    2004-01-01

    An increased frequency of contact allergy to methyldibromoglutaronitrile (MDBGN), a commonly used preservative in cosmetics and other consumer products, has been reported in recent years. A high-performance liquid chromatography (HPLC) method for the determination of MDBGN in cosmetic products has...

  19. Development and validation of methodology for technetium-99m radiopharmaceuticals using high performance liquid chromatography (HPLC)

    International Nuclear Information System (INIS)

    Almeida, Erika Vieira de

    2009-01-01

    Radiopharmaceuticals are compounds, with no pharmacological action, which have a radioisotope in their composition and are used in Nuclear Medicine for diagnosis and therapy of several diseases. In this work, the development and validation of an analytical method for 99 mTc-HSA, 99 mTc-EC, 99 mTc-ECD and 99 mTc-Sestamibi radiopharmaceuticals and for some raw materials were carried out by high performance liquid chromatography (HPLC). The analyses were performed in a Shimadzu HPLC equipment, LC-20AT Prominence model. Some impurities were identified by the addition of a reference standard substance. Validation of the method was carried out according to the criteria defined in RE n. 899/2003 of the National Sanitary Agency (ANVISA). The results for robustness of the method showed that it is necessary to control flow rate conditions, sample volume, pH of the mobile phase and temperature of the oven. The analytical curves were linear in the concentration ranges, with linear correlation coefficients (r 2 ) above 0.9995. The results for precision, accuracy and recovery showed values in the range of 0.07-4.78%, 95.38-106.50% and 94.40-100.95%, respectively. The detection limits and quantification limits varied from 0.27 to 5.77 μg mL -1 and 0.90 to 19.23 μg mL -1 , respectively. The values for HAS, EC, ECD and MIBI in the lyophilized reagents were 8.95; 0.485; 0.986 and 0.974 mg L-1, respectively. The mean radiochemical purity for 99 mTc-HSA, 99 mTc-EC, 99 mTc-ECD and 99 mTc-Sestamibi was (97.28 ± 0.09)%, (98.96 ± 0.03)%, (98.96 ± 0.03)% and (98.07 ± 0.01)%, respectively. All the parameters recommended by ANVISA were evaluated and the results are below the established limits. (author)

  20. Method Development in Forensic Toxicology.

    Science.gov (United States)

    Peters, Frank T; Wissenbach, Dirk K; Busardo, Francesco Paolo; Marchei, Emilia; Pichini, Simona

    2017-01-01

    In the field of forensic toxicology, the quality of analytical methods is of great importance to ensure the reliability of results and to avoid unjustified legal consequences. A key to high quality analytical methods is a thorough method development. The presented article will provide an overview on the process of developing methods for forensic applications. This includes the definition of the method's purpose (e.g. qualitative vs quantitative) and the analytes to be included, choosing an appropriate sample matrix, setting up separation and detection systems as well as establishing a versatile sample preparation. Method development is concluded by an optimization process after which the new method is subject to method validation. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  1. Development and validation of a method for detection and quantification of ochratoxin A in green coffee using liquid chromatography coupled to mass spectrometry Desenvolvimento e validação de metodologia na detecção e na quantificação de Ocratoxina A no café verde utilizando cromatografia líquida acoplada à espectrometria de massas

    Directory of Open Access Journals (Sweden)

    Raquel Duarte da Costa Cunha Bandeira

    2012-12-01

    Full Text Available A method using Liquid Chromatography Tanden Mass Spectrometry (LC-MS/MS with matrix-matched calibration curve was developed and validated for determining ochratoxin A (OTA in green coffee. Linearity was found between 3.0 and 23.0 ng.g-1. Mean recoveries ranged between 90.45% and 108.81%; the relative standard deviation under repeatability and intermediate precision conditions ranged from 5.39% to 9.94% and from 2.20% to 14.34%, respectively. The limits of detection and quantification were 1.2 ng.g-1 and 3.0 ng.g-¹, respectively. The method developed was suitable and contributed to the field of mycotoxin analysis, and it will be used for future production of the Certified Reference Material (CRM for OTA in coffee.Um método utilizando Cromatografia Líquida de Alta Eficiência-Espectrometria de Massas Sequencial (CLAE-EM/EM com curva de calibração em matriz foi desenvolvido e validado para a determinação de ocratoxina A (OTA em café verde. A linearidade foi demonstrada entre 3,0 e 23,0 ng.g-1. As recuperações médias variaram entre 90,45% e 108,81%; o desvio padrão relativo sob condições de repetitividade e precisão intermediária foram de 5,39% e 9,94% e de 2,20% e 14,34%, respectivamente. Os limites de detecção e quantificação foram 1,2 ng.g-1 e 3,0 ng.g-, respectivamente. O método desenvolvido foi adequado, contribuiu para o campo de análises em micotoxinas e será usado para a futura produção de Material de Referência Certificado (MRC para OTA em café.

  2. Multiclass mycotoxin analysis in edible oils using a simple solvent extraction method and liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Eom, Taeyong; Cho, Hyun-Deok; Kim, Junghyun; Park, Mihee; An, Jinyoung; Kim, Moosung; Kim, Sheen-Hee; Han, Sang Beom

    2017-11-01

    A simple and rapid method for the simultaneous determination of 11 mycotoxins - aflatoxins B 1 , B 2 , G 1 and G 2 ; fumonisins B 1 , B 2 and B 3 ; ochratoxin A; zearalenone; deoxynivalenol; and T-2 toxin - in edible oils was established using liquid chromatography tandem mass spectrometry (LC-MS/MS). In this study, QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe), QuEChERS with dispersive liquid-liquid microextraction, and solvent extraction were examined for sample preparation. Among these methods, solvent extraction with a mixture of formic acid/acetonitrile (5/95, v/v) successfully extracted all target mycotoxins. Subsequently, a defatting process using n-hexane was employed to remove the fats present in the edible oil samples. Mass spectrometry was carried out using electrospray ionisation in polarity switching mode with multiple reaction monitoring. The developed LC-MS/MS method was validated by assessing the specificity, linearity, recovery, limit of quantification (LOQ), accuracy and precision with reference to Commission Regulation (EC) 401/2006. Mycotoxin recoveries of 51.6-82.8% were achieved in addition to LOQs ranging from 0.025 ng/g to 1 ng/g. The edible oils proved to be relatively uncomplicated matrices and the developed method was applied to 9 edible oil samples, including soybean oil, corn oil and rice bran oil, to evaluate potential mycotoxin contamination. The levels of detection were significantly lower than the international regulatory standards. Therefore, we expect that our developed method, based on simple, two-step sample preparation process, will be suitable for the large-scale screening of mycotoxin contamination in edible oils.

  3. A simple method for purification of lipopolysaccharides from E. coli 55:B5 using size exclusion chromatography

    International Nuclear Information System (INIS)

    Perdomo, Rolando; Montero, Vivian

    2006-01-01

    Several methods for the extraction of endotoxin or lipopolysaccharide from Gram negative bacteria have been described. However, the product is often contaminated with nucleic acids or proteins in a proportion depending on the extraction method used. Molecular and immunological studies require further purification of the raw LPS. We present here, a simple method for the purification of raw LPS obtained by the standard hot phenol-water procedure using size exclusion chromatography in Sepharose CL-6B. We demonstrated that the using of DNAse and RNAse treatment of the sample before the chromatographic step is necessary to abrogate the nucleic acid contamination in the LPS fraction. The spectrophotometric properties of the pure LPS were verified, supporting the immediate online detection of the LPS and oligonucleotides fractions spectrophotometrically at 206 nm. The mobile phase used (NaCl 0.2 M) do not absorb at 206 nm while maintains the LPS aggregates and therefore, allows the separation of the LPS fraction from the oligoribonucleotide and desoxioligoribonucleotide fractions. The yield of pure LPS was around 98%. Chemical and biological characterizations were conducted in order to assess the feasibility of the procedure developed. (Author)

  4. Validation of a chiral liquid chromatography-tandem mass spectrometry method for the determination of pantoprazole in dog plasma.

    Science.gov (United States)

    Chen, Meixia; Xia, Yu; Ma, Zhiyu; Li, Liang; Zhong, Dafang; Chen, Xiaoyan

    2012-10-01

    Pantoprazole (PAN), a selective proton pump inhibitor, is used clinically as a racemic mixture for the treatment of acid-related gastrointestinal disorders. To investigate its stereoselective pharmacokinetics, a chiral liquid chromatography-tandem mass spectrometry method was developed and validated to determine the pantoprazole enantiomers in dog plasma. After liquid-liquid extraction, a baseline resolution of enantiomers was achieved on an ovomucoid column using the mobile phase of methanol:acetonitrile:10mM ammonium formate (pH 7) (10.4:2.6:87, v/v/v) at 30°C within 10min. Stable isotopically labeled (+)-d(3)-pantoprazole and (-)-d(3)-pantoprazole were used as internal standards. Acquisition of mass spectrometric data was performed in multiple reaction monitoring mode via positive atmospheric pressure chemical ionization. The method was linear in the concentration range of 20.0-10,000ng/mL for each enantiomer using 25μL of dog plasma. The lower limit of quantification (LLOQ) for each enantiomer was 20.0ng/mL. Intra- and inter-day precision ranged from 3.2% to 10.3% for (+)-pantoprazole and 3.7-10.0% for (-)-pantoprazole. Accuracy varied from -1.4% to -0.2% for (+)-pantoprazole and -1.6% to 0.8% for (-)-pantoprazole. The validated method was applied successfully for stereoselective pharmacokinetic studies of racemic pantoprazole. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. A liquid chromatography with tandem mass spectrometry method for quantitating total and unbound ceritinib in patient plasma and brain tumor

    Directory of Open Access Journals (Sweden)

    Xun Bao

    2018-02-01

    Full Text Available A rapid, sensitive, and robust reversed-phase liquid chromatography with tandem mass spectrometry method was developed and validated for the determination of total and unbound ceritinib, a second-generation ALK inhibitor, in patient plasma and brain tumor tissue samples. Sample preparation involved simple protein precipitation with acetonitrile. Chromatographic separation was achieved on a Waters ACQUITY UPLC BEH C18 column using a 4-min gradient elution consisting of mobile phase A (0.1% formic acid in water and mobile phase B (0.1% formic acid in acetonitrile, at a flow rate of 0.4 mL/min. Ceritinib and the internal standard ([13C6]ceritinib were monitored using multiple reaction monitoring mode under positive electrospray ionization. The lower limit of quantitation (LLOQ was 1 nM of ceritinib in plasma. The calibration curve was linear over ceritinib concentration range of 1–2000 nM in plasma. The intra- and inter-day precision and accuracy were within the generally accepted criteria for bioanalytical method (<15%. The method was successfully applied to assess ceritinib brain tumor penetration, as assessed by the unbound drug brain concentration to unbound drug plasma concentration ratio, in patients with brain tumors.

  6. Simple column-switching ion chromatography method for determining eight monosaccharides and oligosaccharides in honeydew and nectar.

    Science.gov (United States)

    Ni, Chengzhu; Zhu, Binhe; Wang, Nani; Wang, Muhua; Chen, Suqing; Zhang, Jiajie; Zhu, Yan

    2016-03-01

    Honeydew is excreted by aphids as a sweet waste and nectar is floral honey. Honeydew and nectar are complicated samples which consist of various sugars and amino acids. In this work, a simple ion chromatography with column-switching method was developed for the simultaneous analysis of 8 monosaccharides and oligosaccharides in honeydew and nectar. A reversed-phase column was used as a pretreatment column to eliminate organics on-line and sugars were eluted from a collection loop to analytical column by using column-switching technique. This method showed good linearity (r⩾0.9994) and afforded low limits of detection ranging from 1.55 to 10.17μgL(-1) for all the analytes. Recoveries ranged from 95% to 105% and repeatability results were acceptable with relative standard deviation of less than 3.21% (n=6). This method was successfully applied to quantification of these sugars in honeydew and nectar. These results showed honeydew had much more oligosaccharides than nectar. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Report: Affinity Chromatography.

    Science.gov (United States)

    Walters, Rodney R.

    1985-01-01

    Supports, affinity ligands, immobilization, elution methods, and a number of applications are among the topics considered in this discussion of affinity chromatography. An outline of the basic principles of affinity chromatography is included. (JN)

  8. NONLINEAR-REGRESSION METHODS FOR MODELING OF HETEROSCEDASTIC RETENTION DATA IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

    NARCIS (Netherlands)

    HENDRIKS, MMWB; COENEGRACHT, PMJ; DOORNBOS, DA

    1994-01-01

    New models have been developed that accurately describe the response surfaces of capacity factors that are a function of changes in the pH and the fraction of organic modifier in reversed-phase high-performance liquid chromatography (RP-HPLC). The purpose of this article is to illustrate one of the

  9. Practical method transfer from high performance liquid chromatography to ultra-high performance liquid chromatography: the importance of frictional heating.

    Science.gov (United States)

    Nováková, Lucie; Veuthey, Jean Luc; Guillarme, Davy

    2011-11-04

    In theory, with identical stationary phase chemistry, the transfer of an HPLC method to UHPLC conditions is straightforward and necessitates the calculation of new conditions based on column and instrument geometries. Occasionally, undesirable changes in selectivity, retention or efficiency have been reported and have been attributed to a frictional heating phenomenon that is due to the elevated generated pressure drop. In the present study, the frictional heating in a UHPLC system was evaluated experimentally under gradient elution conditions (acetonitrile/buffer at pH 3 and 9) with generated pressure drops in the range of 100-1000 bar on both 1.0mm and 2.1mm I.D. columns using a mixture of 10 representative basic, acidic and neutral pharmaceutical compounds. Under adiabatic conditions (i.e., still-air oven), the longitudinal temperature gradient was estimated at +4 °C, +8 °C and +16 °C at 300, 600 and 1000 bar, respectively, on a 2.1mm I.D. column using an empirical measurement procedure. With the 1.0mm I.D. column, these values were reduced to +3 °C, +6 °C and +12 °C, respectively. Finally, various approaches to eliminate or at least to reduce the effect of frictional heating are briefly discussed. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Inverse gas chromatography as a method for determination of surface properties of binding materials

    Science.gov (United States)

    Yu, Jihai; Lu, Xiaolei; Yang, Chunxia; Du, Baoli; Wang, Shuxian; Ye, Zhengmao

    2017-09-01

    Inverse gas chromatography (IGC) is a promising measurement technique for investigating the surface properties of binding materials, which are the major influence element for the adsorption performance of superplasticizer. In this work, using the IGC method, blast furnace slag (BFS), sulphoaluminate cement (SAC) and portland cement (P·O) are employed to systematically evaluate the corresponding dispersive component (γsd), specific surface free energy (γsab), and acid-base properties. The obtained results show that γsd contributes to a major section of the surface free energy in the three binding materials, suggesting they are of a relatively low polarity. Compared to the two kinds of cements, the BFS possesses the highest dispersive and specific surface free energies (the values are 45.01 mJ/m2 and 11.68 mJ/m2, respectively), and also exhibits a wider distribution range of γsd, indicating their surfaces are heterogeneous. For acid-base properties, the results indicate the surfaces of three samples are basic in nature. In addition, the adsorption investigation shows that per unit surface of BFS adsorbs the most superplasticizer molecules, which indicates the higher surface free energies is beneficial to the superplasticizer adsorption.

  11. A gas chromatography-mass spectrometry method for the quantitation of clobenzorex.

    Science.gov (United States)

    Cody, J T; Valtier, S

    1999-01-01

    Drugs metabolized to amphetamine or methamphetamine are potentially significant concerns in the interpretation of amphetamine-positive urine drug-testing results. One of these compounds, clobenzorex, is an anorectic drug that is available in many countries. Clobenzorex (2-chlorobenzylamphetamine) is metabolized to amphetamine by the body and excreted in the urine. Following administration, the parent compound was detectable for a shorter time than the metabolite amphetamine, which could be detected for days. Because of the potential complication posed to the interpretation of amphetamin-positive drug tests following administration of this drug, the viability of a current amphetamine procedure using liquid-liquid extraction and conversion to the heptafluorobutyryl derivative followed by gas chromatography-mass spectrometry (GC-MS) analysis was evaluated for identification and quantitation of clobenzorex. Qualitative identification of the drug was relatively straightforward. Quantitative analysis proved to be a far more challenging process. Several compounds were evaluated for use as the internal standard in this method, including methamphetamine-d11, fenfluramine, benzphetamine, and diphenylamine. Results using these compounds proved to be less than satisfactory because of poor reproducibility of the quantitative values. Because of its similar chromatographic properties to the parent drug, the compound 3-chlorobenzylamphetamine (3-Cl-clobenzorex) was evaluated in this study as the internal standard for the quantitation of clobenzorex. Precision studies showed 3-Cl-clobenzorex to produce accurate and reliable quantitative results (within-run relative standard deviations [RSDs] clobenzorex.

  12. A Straightforward Method for Glucosinolate Extraction and Analysis with High-pressure Liquid Chromatography (HPLC).

    Science.gov (United States)

    Grosser, Katharina; van Dam, Nicole M

    2017-03-15

    Glucosinolates are a well-studied and highly diverse class of natural plant compounds. They play important roles in plant resistance, rapeseed oil quality, food flavoring, and human health. The biological activity of glucosinolates is released upon tissue damage, when they are mixed with the enzyme myrosinase. This results in the formation of pungent and toxic breakdown products, such as isothiocyanates and nitriles. Currently, more than 130 structurally different glucosinolates have been identified. The chemical structure of the glucosinolate is an important determinant of the product that is formed, which in turn determines its biological activity. The latter may range from detrimental (e.g., progoitrin) to beneficial (e.g., glucoraphanin). Each glucosinolate-containing plant species has its own specific glucosinolate profile. For this reason, it is important to correctly identify and reliably quantify the different glucosinolates present in brassicaceous leaf, seed, and root crops or, for ecological studies, in their wild relatives. Here, we present a well-validated, targeted, and robust method to analyze glucosinolate profiles in a wide range of plant species and plant organs. Intact glucosinolates are extracted from ground plant materials with a methanol-water mixture at high temperatures to disable myrosinase activity. Thereafter, the resulting extract is brought onto an ion-exchange column for purification. After sulfatase treatment, the desulfoglucosinolates are eluted with water and the eluate is freeze-dried. The residue is taken up in an exact volume of water, which is analyzed by high-pressure liquid chromatography (HPLC) with a photodiode array (PDA) or ultraviolet (UV) detector. Detection and quantification are achieved by conducting comparisons of the retention times and UV spectra of commercial reference standards. The concentrations are calculated based on a sinigrin reference curve and well-established response factors. The advantages and

  13. Recent developments in methods for analysis of perfluorinated persistent pollutants

    International Nuclear Information System (INIS)

    Trojanowicz, Marek; Koc, Mariusz

    2013-01-01

    Perfluoroalkyl substances (PFASs) are proliferated into the environment on a global scale and present in the organisms of animals and humans even in remote locations. Persistent organic pollutants of that kind therefore have stimulated substantial improvement in analytical methods. The aim of this review is to present recent achievements in PFASs determination in various matrices with different methods and its comparison to measurements of Total Organic Fluorine (TOF). Analytical methods used for PFASs determinations are dominated by chromatography, mostly in combination with mass spectrometric detection. However, HPLC may be also hyphenated with conductivity or fluorimetric detection, and gas chromatography may be combined with flame ionization or electron capture detection. The presence of a large number of PFASs species in environmental and biological samples necessitates parallel attempts to develop a total PFASs index that reflects the total content of PFASs in various matrices. Increasing attention is currently paid to the determination of branched isomers of PFASs, and their determination in food. (author)

  14. Effect of kinetic properties of extraction systems on separation of some elements by liquid chromatography method with free fixed phase

    International Nuclear Information System (INIS)

    Fedotov, P.S.; Maryutina, T.A.; Pichugin, A.A.; Spivakov, B.Ya.

    1993-01-01

    Effect of kinetic properties of a series of extraction systems on the separation of certain elements by the method of liquid chromatography with free fixed phase is considered. Chromatographic behaviour of europium 3 and iron 3 ions when using systems based on di-2-ethylhexylphosphovers acid and tetraphenylmethylenediphosphine dioxide is investigated. Kinetic properties of the extraction systems used are studied by diffusion cell method with mixing, europium 3 and iron 3 mass transfer coefficients are determined

  15. High-performance liquid chromatography electrospray mass spectrometry as a method in proteomic research

    International Nuclear Information System (INIS)

    Walcher, W.

    2003-06-01

    During the sequencing of the human genome it became clear, that a lot of human diseases and/or malfunctions don't base on genomic information, but on differences at the protein level. Therefore biochemistry, biology and medicine are faced to various novel problems where new and authentic analysis methods are needed. Miniaturized chromatographic separation methods are frequently the methods of choice for the separation of peptides and proteins, when the amount of sample is limited. Monolithic capillary columns were prepared by copolymerization of styrene and divinylbenzene in the presence of a suitable porogen mixture of 1-decanol and tetrahydrofuran. The synthesized columns enabled the highly efficient separation of peptides and proteins by reversed-phase high-performance liquid chromatography (RP-HPLC) with peak capacities of 80 and more in 10 minutes. By the hyphenation of RP-HPLC to electrospray mass spectrometry (ESI-MS) the potential of the analysis method was even extended. The monolithic column technology was further miniaturized from 200 μm to 100 and 50 μm inner diameters to improve detection limits by RP-HPLC-ESI-MS. After the optimization of the RP-HPLC-ESI-MS method, the ion source and the ion transfer optics of an ion trap mass spectrometer (LCQ classic, Thermofinnigan) have been advanced for protein and peptide analysis. The improved RP-HPLC-ESI-MS system was subsequently applied to the detection of posttranslational protein modifications at the example of the nitration of bovine serum albumin (BSA). The results of the RP-HPLC-ESI-MS analysis were found to be highly reproducible, which enabled the determination of nitration degrees for different tyrosine residues in the protein sequence. Y 1 60, Y 4 96 and Y 3 52 or Y369 were found to be the predominant positions of protein nitration in BSA. At last light harvesting proteins from the photosystem II (PSII) of higher plants have been analyzed by RP-HPLC-ESI-MS and RP-HPLC-ESI-MSMS. Beside the

  16. A method for screening active components from Chinese herbs by cell membrane chromatography-offline-high performance liquid chromatography/mass spectrometry and an online statistical tool for data processing.

    Science.gov (United States)

    Cao, Yan; Wang, Shaozhan; Li, Yinghua; Chen, Xiaofei; Chen, Langdong; Wang, Dongyao; Zhu, Zhenyu; Yuan, Yongfang; Lv, Diya

    2018-03-09

    Cell membrane chromatography (CMC) has been successfully applied to screen bioactive compounds from Chinese herbs for many years, and some offline and online two-dimensional (2D) CMC-high performance liquid chromatography (HPLC) hyphenated systems have been established to perform screening assays. However, the requirement of sample preparation steps for the second-dimensional analysis in offline systems and the need for an interface device and technical expertise in the online system limit their extensive use. In the present study, an offline 2D CMC-HPLC analysis combined with the XCMS (various forms of chromatography coupled to mass spectrometry) Online statistical tool for data processing was established. First, our previously reported online 2D screening system was used to analyze three Chinese herbs that were reported to have potential anti-inflammatory effects, and two binding components were identified. By contrast, the proposed offline 2D screening method with XCMS Online analysis was applied, and three more ingredients were discovered in addition to the two compounds revealed by the online system. Then, cross-validation of the three compounds was performed, and they were confirmed to be included in the online data as well, but were not identified there because of their low concentrations and lack of credible statistical approaches. Last, pharmacological experiments showed that these five ingredients could inhibit IL-6 release and IL-6 gene expression on LPS-induced RAW cells in a dose-dependent manner. Compared with previous 2D CMC screening systems, this newly developed offline 2D method needs no sample preparation steps for the second-dimensional analysis, and it is sensitive, efficient, and convenient. It will be applicable in identifying active components from Chinese herbs and practical in discovery of lead compounds derived from herbs. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Liquid chromatography – tandem mass spectrometry method for the determination of ten tetracycline residues in muscle samples

    Directory of Open Access Journals (Sweden)

    Gajda Anna

    2015-09-01

    Full Text Available A liquid chromatography – tandem mass spectrometry (LC-MS/MS method for the determination of oxytetracycline (OTC, 4-epi oxytetracycline (4-epi OTC, tetracycline (TC, 4-epi tetracycline (4-epi TC, chlortetracycline (CTC, 4-epi chlortetracycline (4-epi CTC, doxycycline (DC, minocycline (MINO, methacycline (META and rolitetracycline (ROLI residues in muscles was developed. The procedure consisted of an oxalic acid extraction followed by protein removal with trichloroacetic acid. Further solid phase clean-up on polymeric (Strata X reversed phase columns was performed to obtain an extract suitable for LC-MS/MS analysis. The tetracyclines were separated on a C 18 analytical column with mobile phase consisting of 0.01% formic acid in acetonitrile and 0.01% formic acid in water in gradient mode. The method was validated according to the Commission Decision 2002/657/EC. The recoveries of all target compounds were 91.8% – 103.6%. The decision limits were from 109.0 to 119.8 μg/kg and detection capability varied within the range of 122.2 to 137.6 μg/kg, depending on the analyte.

  18. Schinus terebinthifolius countercurrent chromatography (Part II): Intra-apparatus scale-up and inter-apparatus method transfer.

    Science.gov (United States)

    Costa, Fernanda das Neves; Vieira, Mariana Neves; Garrard, Ian; Hewitson, Peter; Jerz, Gerold; Leitão, Gilda Guimarães; Ignatova, Svetlana

    2016-09-30

    Countercurrent chromatography (CCC) is being widely used across the world for purification of various materials, especially in natural product research. The predictability of CCC scale-up has been successfully demonstrated using specially designed instruments of the same manufacturer. The reality is that the most of CCC users do not have access to such instruments and do not have enough experience to transfer methods from one CCC column to another. This unique study of three international teams is based on innovative approach to simplify the scale-up between different CCC machines using fractionation of Schinus terebinthifolius berries dichloromethane extract as a case study. The optimized separation methodology, recently developed by the authors (Part I), was repeatedly performed on CCC columns of different design available at most research laboratories across the world. Hexane - ethyl acetate - methanol - water (6:1:6:1, v/v/v/v) was used as solvent system with masticadienonic and 3β-masticadienolic acids as target compounds to monitor stationary phase retention and calculate peak resolution. It has been demonstrated that volumetric, linear and length scale-up transfer factors based on column characteristics can be directly applied to different i.d., volume and length columns independently on instrument make in an intra-apparatus scale-up and inter-apparatus method transfer. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Comparative Analysis of Volatile Defensive Secretions of Three Species of Pyrrhocoridae (Insecta: Heteroptera by Gas Chromatography-Mass Spectrometric Method.

    Directory of Open Access Journals (Sweden)

    Jan Krajicek

    Full Text Available The true bugs (Hemiptera: Heteroptera have evolved a system of well-developed scent glands that produce diverse and frequently strongly odorous compounds that act mainly as chemical protection against predators. A new method of non-lethal sampling with subsequent separation using gas chromatography with mass spectrometric detection was proposed for analysis of these volatile defensive secretions. Separation was performed on Rtx-200 column containing fluorinated polysiloxane stationary phase. Various mechanical irritation methods (ultrasonics, shaking, pressing bugs with plunger of syringe were tested for secretion sampling with a special focus on non-lethal irritation. The preconcentration step was performed by sorption on solid phase microextraction (SPME fibers with different polarity. For optimization of sampling procedure, Pyrrhocoris apterus was selected. The entire multi-parameter optimization procedure of secretion sampling was performed using response surface methodology. The irritation of bugs by pressing them with a plunger of syringe was shown to be the most suitable. The developed method was applied to analysis of secretions produced by adult males and females of Pyrrhocoris apterus, Pyrrhocoris tibialis and Scantius aegyptius (all Heteroptera: Pyrrhocoridae. The chemical composition of secretion, particularly that of alcohols, aldehydes and esters, is species-specific in all three pyrrhocorid species studied. The sexual dimorphism in occurrence of particular compounds is largely limited to alcohols and suggests their epigamic intraspecific function. The phenetic overall similarities in composition of secretion do not reflect either relationship of species or similarities in antipredatory color pattern. The similarities of secretions may be linked with antipredatory strategies. The proposed method requires only a few individuals which remain alive after the procedure. Thus secretions of a number of species including even the rare

  20. Desenvolvimento e validação de um método cromatográfico em fase gasosa para análise da 3,4-metilenodioximetanfetamina (ecstasy e outros derivados anfetamínicos em comprimidos Development and validation of a gas chromatography method for determination of ecstasy and amphetamines derivatives in tablets

    Directory of Open Access Journals (Sweden)

    Marcelo Carvalho Lasmar

    2007-06-01

    laboratories of toxicology of the development countries as Brazil. It was chosen for development and validation a gas chromatography method with flame ionization detection. The analytic validation results for MDMA, MDA and MDEA were linearity range of 1.0 to 500.0 µg/mL, intra and interassay coefficient of variation lower than 9.5% and quantification limit of 1.0 µg/mL. The detection limits were 0.7 µg/mL, 0.8 µg/mL and 0.6 µg/mL respectively to MDMA, MDA and MDEA. The method showed a good seletivity as the epinephrine, cocaine, amphetamine, methamphetamine, acethyl salicilic acid, diethyl barbituric acid, p-aminobenzoyl diethyl barbituric, paracetamol and caffeine presences did not interfere with the measurement of the three analytes.

  1. Biological Methods and Manual Development

    Science.gov (United States)

    EPA scientists conduct research to develop and evaluate analytical methods for the identification, enumeration, evaluation of aquatic organisms exposed to environmental stressors and to correlate exposures with effects on chemical and biological indicators

  2. DDOT MXD+ method development report.

    Science.gov (United States)

    2015-09-01

    Mixed-use development has become increasingly common across the country, including Washington, D.C. : However, a straightforward and empirically validated method for evaluating the traffic impacts of such : projects is still needed. The data presente...

  3. Developing chiral technologies. Optical division by liquid chromatography; Hattensuru kiraru technology. Ekitai chromatography ni yoru kogaku bunkatsu

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, a. [Daicel Chemical Industries, Ltd., Osaka (Japan)

    1998-05-01

    Optical division using chiral fixing phase for polysaccharide derivative based HPLC has been exhibiting superior capability as an analysis means. It now has transcended the framework of analysis as a result of the encounter with the SMB process, and is completing itself as an optically active body manufacturing means. This paper introduces the following examples of applying the chiral fixing phase for HPLC using polysaccharide derivatives as an unconformity identifier to the unconformity identifying mechanism and mass synthesis: 1) aromatic groups and carbamate groups as substitution groups are arranged regularly along a polysaccharide main chain having a regular and unconformable stereostructure, and a certain `unconformity identification field` is formed: 2) hydrogen bonding and dipole-to-dipole interactions take place between solutes in the ester groups and carbamate groups, and such an interaction act as stacking of aromatic rings among those having aromatic rings; and as a result, interactions in 2) occur in the `unconformity identification field` in 1), where the unconformity identification is executed. This paper describes the pseudo migration bed (SMB) process developed by UOP Corporation as a method for mass-synthesizing fillers for the polysaccharide derivative based HPLC. 6 refs., 3 figs.

  4. Negotiating a Systems Development Method

    Science.gov (United States)

    Karlsson, Fredrik; Hedström, Karin

    Systems development methods (or methods) are often applied in tailored version to fit the actual situation. Method tailoring is in most the existing literature viewed as either (a) a highly rational process with the method engineer as the driver where the project members are passive information providers or (b) an unstructured process where the systems developer makes individual choices, a selection process without any driver. The purpose of this chapter is to illustrate that important design decisions during method tailoring are made by project members through negotiation. The study has been carried out using the perspective of actor-network theory. Our narratives depict method tailoring as more complex than (a) and (b) show the driver role rotates between the project members, and design decisions are based on influences from several project members. However, these design decisions are not consensus decisions.

  5. A sensitive and selective liquid chromatography/tandem mass spectrometry method for quantitative analysis of efavirenz in human plasma.

    Directory of Open Access Journals (Sweden)

    Praveen Srivastava

    Full Text Available A selective and a highly sensitive method for the determination of the non-nucleoside reverse transcriptase inhibitor (NNRTI, efavirenz, in human plasma has been developed and fully validated based on high performance liquid chromatography tandem mass spectrometry (LC-MS/MS. Sample preparation involved protein precipitation followed by one to one dilution with water. The analyte, efavirenz was separated by high performance liquid chromatography and detected with tandem mass spectrometry in negative ionization mode with multiple reaction monitoring. Efavirenz and ¹³C₆-efavirenz (Internal Standard, respectively, were detected via the following MRM transitions: m/z 314.20243.90 and m/z 320.20249.90. A gradient program was used to elute the analytes using 0.1% formic acid in water and 0.1% formic acid in acetonitrile as mobile phase solvents, at a flow-rate of 0.3 mL/min. The total run time was 5 min and the retention times for the internal standard (¹³C₆-efavirenz and efavirenz was approximately 2.6 min. The calibration curves showed linearity (coefficient of regression, r>0.99 over the concentration range of 1.0-2,500 ng/mL. The intraday precision based on the standard deviation of replicates of lower limit of quantification (LLOQ was 9.24% and for quality control (QC samples ranged from 2.41% to 6.42% and with accuracy from 112% and 100-111% for LLOQ and QC samples. The inter day precision was 12.3% and 3.03-9.18% for LLOQ and quality controls samples, and the accuracy was 108% and 95.2-108% for LLOQ and QC samples. Stability studies showed that efavirenz was stable during the expected conditions for sample preparation and storage. The lower limit of quantification for efavirenz was 1 ng/mL. The analytical method showed excellent sensitivity, precision, and accuracy. This method is robust and is being successfully applied for therapeutic drug monitoring and pharmacokinetic studies in HIV-infected patients.

  6. Liquid chromatography tandem mass spectrometry method for the estimation of lamotrigine in human plasma: Application to a pharmacokinetic study

    Directory of Open Access Journals (Sweden)

    Santosh Ghatol

    2013-04-01

    Full Text Available A reliable, selective and sensitive liquid chromatography tandem mass spectrometry method was developed and validated for the quantification of lamotrigine in human plasma using lamotrigine-13C3, d3 as an internal standard. Analyte and internal standard were extracted from human plasma by solid-phase extraction and detected in positive ion mode by tandem mass spectrometry with electrospray ionization (ESI interface. Chromatographic separation was performed on a Chromolith® SpeedROD; RP-18e column (50−4.6 mm i.d. using acetonitrile: 5±0.1 mM ammonium formate solution (90:10, v/v as the mobile phase at a flow rate of 0.500 mL/min. The calibration curves were linear over the range of 5.02–1226.47 ng/mL with the lower limit of quantitation validated at 5.02 ng/mL. The analytes were found stable in human plasma through three freeze (−20 °C-thaw (ice-cold water bath cycles and under storage on bench-top in ice-cold water bath for at least 6.8 h, and also in the mobile phase at 10 °C for at least 57 h. The method has shown good reproducibility, as the intra- and inter-day precisions were within 3.0%, while the accuracies were within ±6.0% of nominal values. The validated LC–MS/MS method was applied for the evaluation of pharmacokinetic and bioequivalence parameters of lamotrigine after an oral administration of 50 mg lamotrigine tablet to thirty-two healthy adult male volunteers. Keywords: Lamotrigine, Liquid chromatography/tandem mass spectrometry, Solid phase extraction, Pharmacokinetic study

  7. A Simple Thin Layer Chromatography Method for Separation of Selected Natural Steroid Hormones

    International Nuclear Information System (INIS)

    Nowakowska, J.; Rudnicka-Litka, K.; Ciura, K.; Pikul, P.; Piotrowicz, J.

    2015-01-01

    Chromatographic properties of seven steroids: estrogens (β-estradiol and estrone), androgens (testosterone, methyltestosterone, trans-androsterone), progesterone and cholesterol have been studied by planar chromatography with usage of High Performance Thin Layer Chromatography (HPTLC) and Thin Layer Chromatography (TLC) plates. Normal, reversed and cyano-bonded silica stationary phases were tested with five binary mobile phases (acetonitrile-water, acetonitrile-DMSO, acetonitrile-methanol, acetone-petroleum ether, acetone-water) in which the concentration of organic modifier varied from 0 to 100 % (v/v). This study reports the optimization of steroid hormones separation. Principal Component Analysis (PCA) based on calculated molecular descriptors quantitatively differentiating solutes was performed in order to investigate the similarity and dissimilarity between tested compounds. The separation abilities of mobile and stationary phases were compared based on separation factor α. Chromatographic retention data and possible retention mechanisms also were discussed. (author)

  8. A high-performance liquid chromatography-electronic circular dichroism online method for assessing the absolute enantiomeric excess and conversion ratio of asymmetric reactions

    Science.gov (United States)

    Zhang, Xiang; Wang, Mingchao; Li, Li; Yin, Dali

    2017-03-01

    Asymmetric reactions often need to be evaluated during the synthesis of chiral compounds. However, traditional evaluation methods require the isolation of the individual enantiomer, which is tedious and time-consuming. Thus, it is desirable to develop simple, practical online detection methods. We developed a method based on high-performance liquid chromatography-electronic circular dichroism (HPLC-ECD) that simultaneously analyzes the material conversion ratio and absolute optical purity of each enantiomer. In particular, only a reverse-phase C18 column instead of a chiral column is required in our method because the ECD measurement provides a g-factor that describes the ratio of each enantiomer in the mixtures. We used our method to analyze the asymmetric hydrosilylation of β-enamino esters, and we discussed the advantage, feasibility, and effectiveness of this new methodology.

  9. Comparison of extraction chromatography and a procedure based on the molecular recognition method as separation methods in the determination of neptunium and plutonium radionuclides

    International Nuclear Information System (INIS)

    Strisovska, Jana; Galanda, Dusan; Drabova, Veronika; Kuruc, Jozef

    2012-01-01

    The potential of various types of sorbents for separation of radionuclides of plutonium and neptunium were examined. Extraction chromatography and a procedure based on the molecular recognition method were used for the separation. The suitability of the various sorbent types and brands for this purpose was determined. (orig.)

  10. Development of high performance liquid chromatography for rapid determination of burn-up of nuclear fuels

    International Nuclear Information System (INIS)

    Joseph, M.; Karunasagar, D.; Saha, B.

    1996-01-01

    Burn-up an important parameter during evaluation of the performance of any nuclear fuel. Among the various techniques available, the preferred one for its determination is based on accurate measurement of a suitable fission product monitor and the residual heavy elements. Since isotopes of rare earth elements are generally used as burn-up monitors, conditions were standardized for rapid separation (within 15 minutes) of light rare earths using high performance liquid chromatography based on either anion exchange (Partisil 10 SAX) in methanol-nitric acid medium or by cation exchange on a reverse phase column (Spherisorb 5-ODS-2 or Supelcosil LC-18) dynamically modified with 1-octane sulfonate or camphor-10-sulfonic acid (β). Both these methods were assessed for separation of individual fission product rare earths from their mixtures. A new approach has been examined in detail for rapid assay of neodymium, which appears promising for faster and accurate measurement of burn-up. (author)

  11. Rapid methods to determine procyanidins, anthocyanins, theobromine and caffeine in rat tissues by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Serra, Aida; Macià, Alba; Romero, Maria-Paz; Piñol, Carme; Motilva, Maria-José

    2011-06-01

    Rapid, selective and sensitive methods were developed and validated to determine procyanidins, anthocyanins and alkaloids in different biological tissues, such as liver, brain, the aorta vein and adipose tissue. For this purpose, standards of procyanidins (catechin, epicatechin, and dimer B(2)), anthocyanins (cyanidin-3-glucoside and malvidin-3-glucoside) and alkaloids (theobromine, caffeine and theophylline) were used. The methods included the extraction of homogenized tissues by off-line liquid-solid extraction, and then solid-phase extraction to analyze alkaloids, or microelution solid-phase extraction plate for the analysis of procyanidins and anthocyanins. The eluted extracts were then analyzed by ultra-performance liquid chromatography-electrospray ionization-tandem mass spectrometry, using a triple quadrupole as the analyzer. The optimum extraction solution was water/methanol/phosphoric acid 4% (94/4.5/1.5, v/v/v). The extraction recoveries were higher than 81% for all the studied compounds in all the tissues, except the anthocyanins, which were between 50 and 65% in the liver and brain. In order to show the applicability of the developed methods, different rat tissues were analyzed to determine the procyanidins, anthocyanins and alkaloids and their generated metabolites. The rats had previously consumed 1g of a grape pomace extract (to analyze procyanidins and anthocyanins) or a cocoa extract (to analyze alkaloids) per kilogram of body weight. Different tissues were extracted 4h after administration of the respective extracts. The analysis of the metabolites revealed a hepatic metabolism of procyanidins. The liver was the tissue which produced a greater accumulation of these metabolites. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. New separation and detection methods in capillary electrophoresis and ion chromatography for the analysis of ionic compounds

    International Nuclear Information System (INIS)

    Mayrhofer, K.

    1999-10-01

    The first part of the thesis deals with the simultaneous analysis of inorganic anions and organic acids in electrodeposition coatings with the co-electroosmotic capillary electrophoresis. The coating of workpieces, e.g. car bodies, by means of an electrodeposition process is an important methodology especially in the automotiv industries. It is usually performed by introducing the object into a basin filled with a water-based electro-dipcoat, applying a voltage of 200-400 Volts (direct current) and using the bodywork as cathode. Because the workpiece has to pass a number of preliminary treatments before the coating procedure, ionic compound may be carried into the basin. If the concentrations of these ionic impurities is too high, the electro-deposition of the binding agent fails or the thickness of the coating is not reproducible. The organic acids are used as neutralization agents in order to control and to keep the pH of the basin constant. The common method of analysing ionic impurities is ion chromatography. The organic acids have to be separated in an ion exclusion chromatography column because organic acids may coelute with the inorganic anions or elute with the dead volume. Therefore a separation method for capillary electrophoresis was developed which enables the simultaneouse analysis of inorganic anions and organic acids in less then 5 minutes. Chloride, nitrate, sulfate, fuoride, phosphate, carbonate, formic acid, acetic acid, lactic acid and butyric acid were detected with indirect UV-detection at 254 nm. For removal of the the binding agent and the pigments the lacquer was mixed with a 0.01 M sodium hydroxide solution and then filtered through a 0.45 μm filter cartridge. 5 mM trimellitic acid, titrated with sodium hydroxid to pH 10, 0.001 % hexadimethrinbromide and 20 % acetonitrile served as buffer. The analytes were separated with a satisfactory resolution. Between every analysis the fused silica capillary was purged for two minutes with buffer. So

  13. A method of sample preparation for N15 determination in amino acids separated by paper chromatography

    International Nuclear Information System (INIS)

    Secer, M.

    1988-01-01

    The amino acids separated with two dimensional paper chromatography were isolated in two ways which make their 15 N determination possible 1) After developing the spots of chromatograms with ninhydrin they were cut out and shaken 30' with 2 ml dist. H 2 O. To destroy the ninhydrin-NH 3 colour complex, the extraction solution was heated in boiling waterbath for 10' and then 0.5 ml 2 N HCl was added to the solution and continued to heat for further 10'. For the 15 N determination of amino acids by emissionspectrometer this colour complex must be destroyed completely. It was reached with adding 2 ml 30% H 2 O 2 to the solution and heating it 5' in 100 0 C waterbath. After the evaporation of colourless solution under IR-lamp at 70 0 C, the white powder was dissolved with 50 ul dist. H 2 O and centrifuged 10'. The clear supernatant was used to gain N 2 gas by the CuO/CaO combustion. N 2 gas is necessary for the 15 N/ 14 N ratio determination by emissionsspectrometer. 2) In the second way, the destroying of ninhydrin-NH 3 colour complex was easier and quicker this way the spots were eluted (extracted) with 50% alcohol and 30% H 2O2 with 1:1 ratio. After shaking the solution 30', it turns quite colourless. It means that the ninhydrin-NH 3 colour complex was completely destroyed. Further works have been done as described in the first way. We have found out that one amino acid should have 10-20 ug N in it to assess the 15 N enrichment. In order to attain this quantity of N for certain amino acids, the spots of three separately run chromatograms were combined

  14. A validated high performance thin layer chromatography method for determination of yohimbine hydrochloride in pharmaceutical preparations

    OpenAIRE

    Jihan M Badr

    2013-01-01

    Background: Yohimbine is an indole alkaloid used as a promising therapy for erectile dysfunction. A number of methods were reported for the analysis of yohimbine in the bark or in pharmaceutical preparations. Materials and Method: In the present work, a simple and sensitive high performance thin layer chromatographic method is developed for determination of yohimbine (occurring as yohimbine hydrochloride) in pharmaceutical preparations and validated according to International Conference of Ha...

  15. Determination of avermectins by the internal standard recovery correction - high performance liquid chromatography - quantitative Nuclear Magnetic Resonance method.

    Science.gov (United States)

    Zhang, Wei; Huang, Ting; Li, Hongmei; Dai, Xinhua; Quan, Can; He, Yajuan

    2017-09-01

    Quantitative Nuclear Magnetic Resonance (qNMR) is widely used to determine the purity of organic compounds. For the compounds with lower purity especially molecular weight more than 500, qNMR is at risk of error for the purity, because the impurity peaks are likely to be incompletely separated from the peak of major component. In this study, an offline ISRC-HPLC-qNMR (internal standard recovery correction - high performance liquid chromatography - qNMR) was developed to overcome this problem. It is accurate by excluding the influence of impurity; it is low-cost by using common mobile phase; and it extends the applicable scope of qNMR. In this method, a mix solution of the sample and an internal standard was separated by HPLC with common mobile phases, and only the eluents of the analyte and the internal standard were collected in the same tube. After evaporation and re-dissolution, it was determined by qNMR. A recovery correction factor was determined by comparison of the solutions before and after these procedures. After correction, the mass fraction of analyte was constant and it was accurate and precise, even though the sample loss varied during these procedures, or even in bad resolution of HPLC. Avermectin B 1 a with the purity of ~93% and the molecular weight of 873 was analyzed. Moreover, the homologues of avermectin B 1 a were determined based on the identification and quantitative analysis by tandem mass spectrometry and HPLC, and the results were consistent with the results of traditional mass balance method. The result showed that the method could be widely used for the organic compounds, and could further promote qNMR to become a primary method in the international metrological systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. [Improvement of the method for methylmercury determination in aquatic products using liquid chromatography online coupled with atomic fluorescence spectrometry].

    Science.gov (United States)

    Shang, Xiaohong; Zhao, Yunfeng; Zhang, Lei; Li, Xiaowei; Wu, Yongning

    2011-07-01

    The improvement method was developed for methylmercury determination using liquid chromatography online coupled with cold vapor atomic fluorescence spectrometry (LC-CV-AFS). Cysteine was used as complexing agent in mobile phase instead of mercaptoethanol. Under the optimized conditions, baseline separation of mercury species could be achieved within 8 min on a C18 column with a mobile phase of 5% (v/v) acetonitrile-1 g/L L-cysteine-50 mmol/L ammonium acetate aqueous solution. The linear range of calibration curve of methylmercury was 1-50 microg/L and the limit of detection (S/N = 3) for methylmercury was 0.3 microg/L. Ultrasonication assisted hydrochloric acid extraction was used to extract methylmercury from seafood samples. The sample extract was cleaned up by a C18 solid phase extraction (SPE) cartridge. For validation of the method, certified reference materials and spiked seafood samples were analyzed. The determined methylmercury contents of certified reference materials NIST1566b, BCR464 and GBW10029 agreed well with the certified values. The determined methylmercury values for Food Analysis Performance Assessment Scheme (FAPAS) sample 07115 were satisfied. The recoveries of methylmercury in seafood samples at three spiked levels (10, 50 and 500 microg/kg) ranged from 89% to 112%, including cooked seafood food. The precision of the method based on relative standard deviation (RSD) was not more than 7%. The present method of LC-CV-AFS is accurate, sensitive, simple, and can meet the demand of methylmercury determination in seafood.

  17. Development of chemical isotope labeling liquid chromatography mass spectrometry for silkworm hemolymph metabolomics

    International Nuclear Information System (INIS)

    Shen, Weifeng; Han, Wei; Li, Yunong; Meng, Zhiqi; Cai, Leiming; Li, Liang

    2016-01-01

    -Methyl-D-aspartic and tyrosine were identified. The changes of these biomarkers were likely due to the disruption of the endocrine system of silkworm by DDT. This work illustrates that the method of CIL LC-MS is useful to generate quantitative submetabolome profiles from a small volume of silkworm hemolymph with much higher coverage than conventional LC-MS methods, thereby facilitating the discovery of potential metabolite biomarkers related to EDC or other chemical exposure. - Highlights: • A method was developed for profiling silkworm hemolymph metabolome with high coverage. • Dansylation isotope labeling LC-MS was used for amine/phenol submetabolome quantification. • Metabolomic changes in silkworm after DDT exposure were studied. • Among 2044 metabolites detected, 65 were positively identified and 1809 were putatively identified. • 33 positively identified metabolites showed significant changes in five groups of silkworms.

  18. Development of chemical isotope labeling liquid chromatography mass spectrometry for silkworm hemolymph metabolomics

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Weifeng [Key Laboratory of Detection for Pesticide Residues, Ministry of Agriculture (China); Sericultural Research Institute, Zhejiang Academy of Agricultural Sciences, Hangzhou (China); Han, Wei; Li, Yunong [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada); Meng, Zhiqi [Sericultural Research Institute, Zhejiang Academy of Agricultural Sciences, Hangzhou (China); Cai, Leiming, E-mail: cailm@mail.zaas.ac.cn [Institute of Quality and Standard for Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou (China); Li, Liang, E-mail: Liang.Li@ualberta.ca [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada)

    2016-10-26

    -Methyl-D-aspartic and tyrosine were identified. The changes of these biomarkers were likely due to the disruption of the endocrine system of silkworm by DDT. This work illustrates that the method of CIL LC-MS is useful to generate quantitative submetabolome profiles from a small volume of silkworm hemolymph with much higher coverage than conventional LC-MS methods, thereby facilitating the discovery of potential metabolite biomarkers related to EDC or other chemical exposure. - Highlights: • A method was developed for profiling silkworm hemolymph metabolome with high coverage. • Dansylation isotope labeling LC-MS was used for amine/phenol submetabolome quantification. • Metabolomic changes in silkworm after DDT exposure were studied. • Among 2044 metabolites detected, 65 were positively identified and 1809 were putatively identified. • 33 positively identified metabolites showed significant changes in five groups of silkworms.

  19. Development of High Performance Liquid Chromatography and Mass Spectrometry: a Key Engine of TCM Modernization

    Directory of Open Access Journals (Sweden)

    Zheng-Xiang Zhang

    2015-04-01

    Full Text Available Traditional Chinese Medicine (TCM has been popular for thousand years in prevention and treatment of chronic diseases synergistically with Western medicine while producing mild healing effects and lower side effects. Although many TCMs have been proven effective by modern pharmacological studies and clinical trials, their bioactive constituents and the remedial mechanisms are still not well understood. Researchers have made great efforts to explore the real theory of TCM for many years with different strategies. Development of high performance liquid chromatography (HPLC and mass spectrometry within recent decade can provide scientists with robust technologies for disclosing the mysterious mask of TCM. In this paper, important innovations of HPLC and mass spectrometry are reviewed in the application of TCM analysis from single compound identification to metabolomic strategy.

  20. Setting up of a liquid chromatography-high resolution tandem mass spectrometry method for the detection of caseins in food. A comparison with ELISA method

    Directory of Open Access Journals (Sweden)

    Daniela Gastaldi

    2013-06-01

    Full Text Available Determination of caseins in food matrices is usually performed by using the competitiveenzyme- linked immunosorbent assay (ELISA technique. However such a technique suffers from a number of limitations. Among these, the applicability to a narrow concentration range, a non linear (logarithmic response, a non-negligible cross-reactivity and a high cost per kit. At the time of the completion of this study, in case of ELISA positive feedback, there was poor availability in the literature of finding reliable instrumental methods able to determine both qualitatively and quantitatively this class of substances. In the present study, a liquid chromatography-high resolution tandem mass spectrometry (HPLC-HRMS/MS instrumental method was developed with a high resolution mass spectrometer (Orbitrap. Real samples of sausages in which caseins were detected by ELISA technique were analysed. A casein-free sample of ham was used as a blank. The analytical characteristics of the instrumental method were compared with those of a commercial ELISA test, declared specific for α- and β-casein.

  1. Atmospheric pressure photoionisation : An ionization method for liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Robb, DB; Covey, TR; Bruins, AP

    2000-01-01

    Atmospheric pressure photoionization (APPI) has been successfully demonstrated to provide high sensitivity to LC-MS analysis. A vacuum-ultraviolet lamp designed for photoionization detection in gas chromatography is used as a source of 10-eV photons. The mixture of samples and solvent eluting from

  2. A simple and selective liquid chromatography- tandem mass spectrometry method for determination of ε-aminocaproic acid in human plasma

    Directory of Open Access Journals (Sweden)

    Ganesh S. Moorthy

    2015-07-01

    Full Text Available Understanding the clinical pharmacology of the antifibrinolytic drug epsilon-aminocaproic acid (EACA is critical for rational drug administration in children. The aim of this study is to develop a reliable assay for the determination of EACA in human plasma. We describe a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS assay for EACA in human plasma. Sample preparation involved plasma dilution (1:2040, followed by reversed-phase chromatographic separation and selective detection using tandem mass spectrometry. EACA had a linear range of 1 - 250 μg/mL. The intraday precision based on the standard deviation of replicates of quality control samples ranged from 4.7 to 10.4% and the accuracy ranged from 92-106%. The interday precision ranged from 4.6 to 9.8% and the accuracy ranged from 95-103%. Stability studies showed that EACA was stable during the conditions for sample preparation and storage. The described method is robust and successfully employed for clinical studies of EACA in children

  3. A rapid liquid chromatography tandem mass spectrometry-based method for measuring propranolol on dried blood spots.

    Science.gov (United States)

    Della Bona, Maria Luisa; Malvagia, Sabrina; Villanelli, Fabio; Giocaliere, Elisa; Ombrone, Daniela; Funghini, Silvia; Filippi, Luca; Cavallaro, Giacomo; Bagnoli, Paola; Guerrini, Renzo; la Marca, Giancarlo

    2013-05-05

    Propranolol, a non-selective beta blocker drug, is used in young infants and newborns for treating several heart diseases; its pharmacokinetics has been extensively evaluated in adult patients using extrapolation to treat pediatric population. The purpose of the present study was to develop and validate a method to measure propranolol levels in dried blood spots. The analysis was performed by using liquid chromatography/tandem mass spectrometry operating in multiple reaction monitoring mode. The calibration curve in matrix was linear in the concentration range of 2.5-200 μg/L with correlation coefficient r=0.9996. Intra-day and inter-day precisions and biases were less than 8.0% (n=10) and 11.5% (n=10) respectively. The recoveries ranged from 94 to 100% and the matrix effect did not result in a severe signal suppression. Propranolol on dried blood spot showed a good stability at three different temperatures for one month. This paper describes a micromethod for measuring propranolol levels on dried blood spot, which determines a great advantage in neonates or young infants during pharmacokinetic studies because of less invasive sampling and small blood volume required. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Simultaneous determination of some ultraviolet-absorbing chemicals in sunscreen cosmetics using a high-performance liquid chromatography method.

    Science.gov (United States)

    Liu, T; Wu, D

    2011-10-01

    A method of gradient elution high-performance liquid chromatography (HPLC) for simultaneous determination of 11 different ultraviolet-absorbing chemicals of phenylbenzlmldazole sulphonic acid, 4-aminobenzoic acid, benzophenone-4, benzophenone-3, isoamyl p-methoxycinnamate, 4-methylbenzylidene camphor, octocrylene, ethylhexyl methoxycinnamate, homosalate, ethylhexyl salicylate, methylene bis-benzotriazolyl tetramethylbutyl phenol was developed for the application to sunscreen cosmetic products. In this study, an Agilent SB-C18 analytical column (250 × 4.6 mm, 5 μm) was utilized and methanol, tetrahydrofuran and perchloric acid aqueous solution (0.2 mL HClO(4) + 300 mL H(2)O) were used for gradient elution at a total flow rate of 1.0 mL min(-1). The optimum conditions for 11 different ultraviolet-absorbing chemicals analyses were investigated. All calibration curves showed good linear regression with UV detection (311 nm) within test ranges. The correlation coefficients were better than 0.999 in all cases. The assay was simple, selective, convenient and reproducible and is suitable for the determination of ultraviolet-absorbing chemicals in commercial sunscreen cosmetic products. The use frequency of 11 different ultraviolet absorbents in 100 sunscreen cosmetics was investigated and statistically analysed. The ultraviolet absorbent of maximum use frequency was ethylhexyl methoxycinnamate. © 2011 The Authors. ICS © 2011 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  5. Nontargeted Screening Method for Illegal Additives Based on Ultrahigh-Performance Liquid Chromatography-High-Resolution Mass Spectrometry.

    Science.gov (United States)

    Fu, Yanqing; Zhou, Zhihui; Kong, Hongwei; Lu, Xin; Zhao, Xinjie; Chen, Yihui; Chen, Jia; Wu, Zeming; Xu, Zhiliang; Zhao, Chunxia; Xu, Guowang

    2016-09-06

    Identification of illegal additives in complex matrixes is important in the food safety field. In this study a nontargeted screening strategy was developed to find illegal additives based on ultrahigh-performance liquid chromatography-high-resolution mass spectrometry (UHPLC-HRMS). First, an analytical method for possible illegal additives in complex matrixes was established including fast sample pretreatment, accurate UHPLC separation, and HRMS detection. Second, efficient data processing and differential analysis workflow were suggested and applied to find potential risk compounds. Third, structure elucidation of risk compounds was performed by (1) searching online databases [Metlin and the Human Metabolome Database (HMDB)] and an in-house database which was established at the above-defined conditions of UHPLC-HRMS analysis and contains information on retention time, mass spectra (MS), and tandem mass spectra (MS/MS) of 475 illegal additives, (2) analyzing fragment ions, and (3) referring to fragmentation rules. Fish was taken as an example to show the usefulness of the nontargeted screening strategy, and six additives were found in suspected fish samples. Quantitative analysis was further carried out to determine the contents of these compounds. The satisfactory application of this strategy in fish samples means that it can also be used in the screening of illegal additives in other kinds of food samples.

  6. Liquid chromatography/tandem mass spectrometry method for quantitative estimation of solutol HS15 and its applications

    Directory of Open Access Journals (Sweden)

    V. Vijaya Bhaskar

    2015-04-01

    Full Text Available A rapid, sensitive and selective pseudoMRM (pMRM-based method for the determination of solutol HS15 (SHS15 in rat plasma was developed using liquid chromatography/tandem mass spectrometry (LC–MS/MS. The most abundant ions corresponding to SHS15 free polyethyleneglycol (PEG oligomers at m/z 481, 525, 569, 613, 657, 701, 745, 789, 833, 877, 921 and 965 were selected for pMRM in electrospray mode of ionization. Purity of the lipophilic and hydrophilic components of SHS15 was estimated using evaporative light scattering detector (ELSD. Plasma concentrations of SHS15 were measured after oral administration at 2.50 g/kg dose and intravenous administration at 1.00 g/kg dose in male Sprague Dawley rats. SHS15 has poor oral bioavailability of 13.74% in rats. Differences in pharmacokinetics of oligomers were studied. A novel proposal was conveyed to the scientific community, where formulation excipient could be analyzed as a qualifier in the analysis of new chemical entities (NCEs to address the spiky plasma concentration profiles. Keywords: SHS15, LC–MS/MS, Spiky profiles, Validation

  7. Liquid chromatography/tandem mass spectrometry method for quantitative estimation of solutol HS15 and its applications.

    Science.gov (United States)

    Bhaskar, V Vijaya; Middha, Anil; Srivastava, Pratima; Rajagopal, Sriram

    2015-04-01

    A rapid, sensitive and selective pseudoMRM (pMRM)-based method for the determination of solutol HS15 (SHS15) in rat plasma was developed using liquid chromatography/tandem mass spectrometry (LC-MS/MS). The most abundant ions corresponding to SHS15 free polyethyleneglycol (PEG) oligomers at m / z 481, 525, 569, 613, 657, 701, 745, 789, 833, 877, 921 and 965 were selected for pMRM in electrospray mode of ionization. Purity of the lipophilic and hydrophilic components of SHS15 was estimated using evaporative light scattering detector (ELSD). Plasma concentrations of SHS15 were measured after oral administration at 2.50 g/kg dose and intravenous administration at 1.00 g/kg dose in male Sprague Dawley rats. SHS15 has poor oral bioavailability of 13.74% in rats. Differences in pharmacokinetics of oligomers were studied. A novel proposal was conveyed to the scientific community, where formulation excipient could be analyzed as a qualifier in the analysis of new chemical entities (NCEs) to address the spiky plasma concentration profiles.

  8. Validation of a Multiresidue Analysis Method for 379 Pesticides in Human Serum Using Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Shin, Yongho; Lee, Jonghwa; Lee, Jiho; Lee, Junghak; Kim, Eunhye; Liu, Kwang-Hyeon; Lee, Hye Suk; Kim, Jeong-Han

    2018-04-04

    A screening method for simultaneous analysis of 379 pesticides in human serum was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Electrospray ionization with positive/negative switching mode of LC-MS/MS was adopted, and scheduled multiple reaction monitoring for each target compound was established. The limit of quantitation was 10 ng/mL for 94.5% of the total pesticides, and the correlation coefficients of calibration were ≥0.990 for 93.9% of the pesticides. For the sample preparation, scaled-down QuEChERS were used. Serum (100 μL) was extracted with acetonitrile (400 μL), partitioned with magnesium sulfate (40 mg) and sodium chloride (10 mg), and the upper layer was used for analysis without further cleanup steps. For the accuracy and precision tests, most of the pesticides showed excellent results in intra- and interday conditions. In the recovery tests at 10, 50, and 250 ng/mL, 85.8-91.8% of all target compounds satisfied the recovery range of 70-120% (relative standard deviation ≤20%).

  9. The separation of [32P]inositol phosphates by ion-pair chromatography: Optimization of the method and biological applications

    International Nuclear Information System (INIS)

    Sulpice, J.C.; Gascard, P.; Journet, E.; Rendu, F.; Renard, D.; Poggioli, J.; Giraud, F.

    1989-01-01

    We have developed an ion-pair reverse-phase HPLC method to measure inositol phosphates in 32 P-labeled cells. The different chromatographic parameters were analyzed to optimize the resolution of the 32 P-labeled metabolites. Analysis of inositol phosphates in biological samples was improved by a single charcoal pretreatment which eliminated interfering nucleotides without removing inositol phosphates. The kinetics of production of inositol phosphates in calcium-activated erythrocytes, vasopressin-stimulated hepatocytes, and thrombin-activated platelets were analyzed. Original data on the activation of phosphoinositide phospholipase C were obtained in intact erythrocytes by direct measurement of inositol (1,4,5)P3. Data from agonist-stimulated hepatocytes and platelets were consistent with those from previous studies. In conclusion, this technique offers many advantages over the methodologies currently employed involving anion-exchange chromatography and [ 3 H]inositol labeling: (i) 32 P labeling is less expensive and more efficient than 3 H labeling and can be used with all types of cells without permeabilization treatments and (ii) ion-pair HPLC gives good resolution of inositol phosphates from nucleotides with shorter retention times, and long reequilibration periods are not required

  10. Simple, rapid, and environmentally friendly method for the separation of isoflavones using ultra-high performance supercritical fluid chromatography.

    Science.gov (United States)

    Wu, Wenjie; Zhang, Yuan; Wu, Hanqiu; Zhou, Weie; Cheng, Yan; Li, Hongna; Zhang, Chuanbin; Li, Lulu; Huang, Ying; Zhang, Feng

    2017-07-01

    Isoflavones are natural substances that exhibit hormone-like pharmacological activities. The separation of isoflavones remains an analytical challenge because of their similar structures. We show that ultra-high performance supercritical fluid chromatography can be an appropriate tool to achieve the fast separation of 12 common dietary isoflavones. Among the five tested columns the Torus DEA column was found to be the most effective column for the separation of these isoflavones. The impact of individual parameters on the retention time and separation factor was evaluated. These parameters were optimized to develop a simple, rapid, and green method for the separation of the 12 target analytes. It only took 12.91 min using gradient elution with methanol as an organic modifier and formic acid as an additive. These isoflavones were determined with limit of quantitation ranging from 0.10 to 0.50 μg/mL, which was sufficient for reliable determination of various matrixes. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Quantitative determination of hederagenin in rat plasma and cerebrospinal fluid by ultra fast liquid chromatography-tandem mass spectrometry method.

    Science.gov (United States)

    Yang, Xuemei; Li, Guoliang; Chen, Lingyun; Zhang, Cong; Wan, Xinxiang; Xu, Jiangping

    2011-07-01

    A rapid, sensitive and selective method was developed for the quantitative determination of hederagenin in rat plasma and cerebrospinal fluid (CSF) by ultra fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS). It has been successfully applied in a pharmacokinetic study of hederagenin in the central nervous system (CNS). Sample pretreatment involved a simple protein precipitation with methanol and a one-step extraction with ethyl acetate. Separation was carried out in a Shim-pack XR-ODS II (75 mm × 2.0 mm, i.d., 2.1 μm) column with gradient elution at a flow rate of 0.35 mL/min. The mobile phase was 5mM ammonium acetate and acetonitrile. Detection was performed in a triple-quadruple tandem mass spectrometer by multiple-reaction-monitoring mode via electrospray ionization. A linear calibration curve for hederagenin was obtained over a concentration range of 0.406 (lower limit of quantification, LLOQ) to 203 ng/mL (r² > 0.99) for both plasma and CSF. The intra-day and inter-day precision (relative standard deviation, RSD) values were less than 15%. At all quality control (QC) levels, the accuracy (relative error, RE) was within -9.0% and 11.1% for plasma and CSF, respectively. The pharmacokinetics results indicated that hederagenin could pass through the blood-brain barrier. This UFLC-MS/MS method demonstrates higher sensitivity and sample throughput than previous methods. It was also successfully applied to the pharmacokinetic study of hederagenin following oral administration of Fructus akebiae extract in rats. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Multi-residue analysis method for analysis of pharmaceuticals using liquid chromatography-time of flight/mass spectrometry (LC-TOF/MS) in water sample

    Science.gov (United States)

    Al-Qaim, Fouad Fadhil; Abdullah, Md Pauzi; Othman, Mohamed Rozali

    2013-11-01

    In this work, a developed method using solid - phase extraction (SPE) followed by liquid chromatography - time of flight mass spectrometry (LC-ESI-TOF/MS) was developed and validated for quantification and confirmation of eleven pharmaceuticals with different therapeutic classes in water samples, Malaysia. These compounds are caffeine (CAF), prazosin (PRZ), enalapril (ENL), carbamazepine (CBZ), nifedipine (NFD), levonorgestrel (LNG), simvastatin (SMV), hydrochlorothiazide (HYD), gliclazide (GLIC), diclofenac-Na (DIC-Na) and mefenamic acid (MEF). LC was performed on a Dionex Ultimate 3000/LC 09115047 (USA) system. Chromatography was performed on a Thermo Scientific C18 (250 mm × 2.1 mm, i.d.: 5μm) column. Several parameters were optimised such as; mobile phase, gradient elution, collision energy and solvent elution for extraction of compounds from water. The recoveries obtained ranged from 30-148 % in river water. Five pharmaceutical compounds were detected in the surface water samples: caffeine, prazosin, enalpril, diclofenac-Na and mefenamic acid. The developed method is precise and accepted recoveries were got. In addition, this method is suitable to identify and quantify trace concentrations of pharmaceuticals in surface water.

  13. An analysis method for flavan-3-ols using high performance liquid chromatography coupled with a fluorescence detector

    Directory of Open Access Journals (Sweden)

    Liuqing Wang

    2017-07-01

    Full Text Available Procyanidins belong to a family of flavan-3-ols, which consist of monomers, (+-catechin and (−-epicatechin, and their oligomers and polymers, and are distributed in many plant-derived foods. Procyanidins are reported to have many beneficial physiological activities, such as antihypertensive and anticancer effects. However, the bioavailability of procyanidins is not well understood owing to a lack of convenient and high-sensitive analysis methods. The aim of this study was to develop an improved method for determining procyanidin content in both food materials and biological samples. High performance liquid chromatography (HPLC coupled with a fluorescence detector was used in this study. The limits of detection (LODs of (+-catechin, (−-epicatechin, procyanidin B2, procyanidin C1, and cinnamtannin A2 were 3.0×10−3 ng, 4.0×10−3 ng, 14.0×10−3 ng, 18.5×10−3 ng, and 23.0×10−3 ng, respectively; the limits of quantification (LOQs were 10.0×10−3 ng, 29.0×10−3 ng, 28.5×10−3 ng, 54.1×10−3 ng, and 115.0×10−3 ng, respectively. The LOD and LOQ values indicated that the sensitivity of the fluorescence detector method was around 1000 times higher than that of conventional HPLC coupled with a UV-detector. We applied the developed method to measure procyanidins in black soybean seed coat extract (BE prepared from soybeans grown under three different fertilization conditions, namely, conventional farming, basal manure application, and intertillage. The amount of flavan-3-ols in these BEs decreased in the order intertillage > basal manure application > conventional farming. Commercially available BE was orally administered to mice at a dose of 250 mg/kg body weight, and we measured the blood flavan-3-ol content. Data from plasma analysis indicated that up to the tetramer oligomerization, procyanidins were detectable and flavan-3-ols mainly existed in conjugated forms in the plasma. In conclusion, we developed a highly

  14. Development of Sensitive and Specific Analysis of Vildagliptin in Pharmaceutical Formulation by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Ebru Uçaktürk

    2015-01-01

    Full Text Available A sensitive and selective gas chromatography-mass spectrometry (GC-MS method was developed and fully validated for the determination of vildagliptin (VIL in pharmaceutical formulation. Prior to GC-MS analysis, VIL was efficiently derivatized with MSTFA/NH4I/β-mercaptoethanol at 60°C for 30 min. The obtained O-TMS derivative of VIL was detected by selected ion monitoring mode using the diagnostic ions m/z 223 and 252. Nandrolone was chosen as internal standard. The GC-MS method was fully validated by the following validation parameters: limit of detection (LOD and quantitation (LOQ, linearity, precision, accuracy, specificity, stability, robustness, and ruggedness. LOD and LOQ were found to be 1.5 and 3.5 ng mL−1, respectively. The GC-MS method is linear in the range of 3.5–300 ng mL−1. The intra- and interday precision values were less than ≤3.62%. The intra- and interday accuracy values were found in the range of -0.26–2.06%. Finally, the GC-MS method was successfully applied to determine VIL in pharmaceutical formulation.

  15. Ion Chromatography Applications in Wastewater Analysis

    Directory of Open Access Journals (Sweden)

    Rajmund Michalski

    2018-02-01

    Full Text Available Wastewater analysis is an important area in analytical and environmental chemistry. It can be performed with both the classic wet methods and instrumental techniques. The development of new methods, and modification of the existing ones, constitute a major task for researchers. Ion chromatography plays a predominant role in ion determinations with the instrumental methods. It offers several advantages over the conventional methods, such as simultaneous determinations of alkali and alkaline earth cations and ammonia. Ammonium ions cannot be determined by spectroscopic methods. Ion chromatography has been accepted world-wide as a reference method for analyzing anions and cations in water and wastewater due to the fact that it enables the replacement of several individual wet chemistry methods for common ions with one instrumental technique. The following article describes the principles of ion chromatography, such as stationary phases, eluents, detectors, and sample preparation methods. Moreover, the applications of ion chromatography in wastewater analyses and international standards are presented.

  16. Chromatography in Industry

    Science.gov (United States)

    Schoenmakers, Peter

    2009-07-01

    This review focuses on the chromatography research that has been carried out within industry or in close cooperation with industry and that has been reported in the scientific literature between 2006 and mid-2008. Companies in the health care sector, such as pharmaceutical and biotechnology companies, are the largest contributors. Industrial research seems to take place in an open environment in cooperation with academia, peer companies, and institutions. Industry appears ready to embrace new technologies as they emerge, but they focus strongly on making chromatography work robustly, reliably, rapidly, and automatically. “Hyphenated” systems that incorporate on-line sample-preparation techniques and mass-spectrometric detection are the rule rather than the exception. Various multidimensional separation methods are finding numerous applications. Strategies aimed at speeding up the development of new chromatographic methods remain the focus of attention. Also, there is a clear trend toward exploring chromatographic methods for parallel processing along with other strategies for high-throughput analysis.

  17. Comparison of sample preparation methods for reliable plutonium and neptunium urinalysis using automatic extraction chromatography

    DEFF Research Database (Denmark)

    Qiao, Jixin; Xu, Yihong; Hou, Xiaolin

    2014-01-01

    This paper describes improvement and comparison of analytical methods for simultaneous determination of trace-level plutonium and neptunium in urine samples by inductively coupled plasma mass spectrometry (ICP-MS). Four sample pre-concentration techniques, including calcium phosphate, iron......), it endows urinalysis methods with better reliability and repeatability compared with co-precipitation techniques. In view of the applicability of different pre-concentration techniques proposed previously in the literature, the main challenge behind relevant method development is pointed to be the release...

  18. Determine equilibrium dissociation constant of drug-membrane receptor affinity using the cell membrane chromatography relative standard method.

    Science.gov (United States)

    Ma, Weina; Yang, Liu; Lv, Yanni; Fu, Jia; Zhang, Yanmin; He, Langchong

    2017-06-23

    The equilibrium dissociation constant (K D ) of drug-membrane receptor affinity is the basic parameter that reflects the strength of interaction. The cell membrane chromatography (CMC) method is an effective technique to study the characteristics of drug-membrane receptor affinity. In this study, the K D value of CMC relative standard method for the determination of drug-membrane receptor affinity was established to analyze the relative K D values of drugs binding to the membrane receptors (Epidermal growth factor receptor and angiotensin II receptor). The K D values obtained by the CMC relative standard method had a strong correlation with those obtained by the frontal analysis method. Additionally, the K D values obtained by CMC relative standard method correlated with pharmacological activity of the drug being evaluated. The CMC relative standard method is a convenient and effective method to evaluate drug-membrane receptor affinity. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Simplex-based optimization of numerical and categorical inputs in early bioprocess development: Case studies in HT chromatography.

    Science.gov (United States)

    Konstantinidis, Spyridon; Titchener-Hooker, Nigel; Velayudhan, Ajoy

    2017-08-01

    Bioprocess development studies often involve the investigation of numerical and categorical inputs via the adoption of Design of Experiments (DoE) techniques. An attractive alternative is the deployment of a grid compatible Simplex variant which has been shown to yield optima rapidly and consistently. In this work, the method is combined with dummy variables and it is deployed in three case studies wherein spaces are comprised of both categorical and numerical inputs, a situation intractable by traditional Simplex methods. The first study employs in silico data and lays out the dummy variable methodology. The latter two employ experimental data from chromatography based studies performed with the filter-plate and miniature column High Throughput (HT) techniques. The solute of interest in the former case study was a monoclonal antibody whereas the latter dealt with the separation of a binary system of model proteins. The implemented approach prevented the stranding of the Simplex method at local optima, due to the arbitrary handling of the categorical inputs, and allowed for the concurrent optimization of numerical and categorical, multilevel and/or dichotomous, inputs. The deployment of the Simplex method, combined with dummy variables, was therefore entirely successful in identifying and characterizing global optima in all three case studies. The Simplex-based method was further shown to be of equivalent efficiency to a DoE-based approach, represented here by D-Optimal designs. Such an approach failed, however, to both capture trends and identify optima, and led to poor operating conditions. It is suggested that the Simplex-variant is suited to development activities involving numerical and categorical inputs in early bioprocess development. © 2017 The Authors. Biotechnology Journal published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of febuxostat in dog plasma and its application to a pharmacokinetic study.

    Science.gov (United States)

    Zhang, Tianhong; Sun, Yuanpeng; Zhang, Peng; Gao, Jingmei; Wang, Shanshan; He, Zhonggui

    2013-02-01

    A rapid, sensitive and selective ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the determination of febuxostat in dog plasma. Using paclitaxel as an internal standard (IS), a simple liquid-liquid extraction method with ethyl acetate was adopted for plasma sample pretreatment. Separation was carried out on an Acquity UPLC BEH C(18) column with a mobile phase consisting of acetonitrile and water (containing 0.2% formic acid). The assay was linear in the concentration ranged from 5 to 5000 ng/mL with a lower limit of quantification of 5 ng/mL for febuxostat. The single run analysis was as short as 2.0 min. Finally, the developed method was successfully applied to the pharmacokinetic study of febuxostat tablets following oral administration at a single dose of 40 mg in beagle dogs. Copyright © 2012 John Wiley & Sons, Ltd.

  1. Optimization of ultra-performance liquid chromatography (UPLC) with fluorescence detector (FLD) method for the quantitative determination of selected neurotransmitters in rat brain.

    Science.gov (United States)

    Stragierowicz, Joanna; Daragó, Adam; Brzeźnicki, Sławomir; Kilanowicz, Anna

    2017-07-26

    Glutamate (Glu) and γ-aminobutyric acid (GABA) are the main neurotransmitters in the central nervous system for excitatory and inhibitory processes, respectively. Monitoring these neurotransmitters is an essential tool in establishing pathological functions, among others in terms of occupational exposure to toxic substances. We present modification of the HPLC (high-performance liquid chromatography) to the UPLC (ultra-performance liquid chromatography) method for the simultaneous determination of glutamate and γ-aminobutyric acid in a single injection. The isocratic separation of these neurotransmitter derivatives was performed on Waters Acquity BEH (ethylene bridged hybrid) C18 column with particle size of 1.7 μm at 35°C using a mobile phase consisting of 0.1 M acetate buffer (pH 6.0) and methanol (60:40, v/v) at a flow rate of 0.3 ml/min. The analytes were detected with the fluorescence detector (FLD) using derivatization with o-phthaldialdehyde (OPA), resulting in excitation at 340 nm and emission at 455 nm. Several validation parameters including linearity (0.999), accuracy (101.1%), intra-day precision (1.52-1.84%), inter-day precision (2.47-3.12%), limit of detection (5-30 ng/ml) and quantification (100 ng/ml) were examined. The developed method was also used for the determination of these neurotransmitters in homogenates of selected rat brain structures. The presented UPLC-FLD is characterized by shorter separation time (3.5 min), which is an adaptation of the similar HPLC methods and is an alternative for more expensive references techniques such as liquid chromatography coupled with tandem mass-spectrometry (LC-MS/MS) methods. Med Pr 2017;68(5):583-591. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  2. First liquid chromatography method for the simultaneous determination of levofloxacin, pazufloxacin, gatifloxacin, moxifloxacin and trovafloxacin in human plasma.

    Science.gov (United States)

    Sousa, Joana; Alves, Gilberto; Campos, Gonçalo; Fortuna, Ana; Falcão, Amílcar

    2013-07-01

    For the first time a simple, selective and sensitive liquid chromatography method was developed and validated for the simultaneous determination of levofloxacin (LEV), pazufloxacin (PAZ), gatifloxacin (GAT), moxifloxacin (MOX) and trovafloxacin (TRO) in human plasma. Samples were pre-treated with acetonitrile for precipitation of plasma proteins followed by evaporation and reconstitution steps. Chromatographic separation of the analytes and norfloxacin, used as internal standard (IS), was performed under gradient elution on a LiChroCART(®) Purospher Star C18 column (55mm×4mm, 3μm). The mobile phase comprised a mixture of 0.1% aqueous formic acid adjusted to pH 3.0 with triethylamine, acetonitrile and methanol pumped at a flow rate of 1.0mL/min. The detector was set at excitation/emission wavelengths of 260/455nm. Calibration curves were linear (r(2)≥0.9923) in the ranges of 0.005-5μg/mL for GAT, 0.02-5μg/mL for LEV, PAZ and MOX and 0.04-5μg/mL for TRO. The intra and interday precision did not exceed 7.32% and the intra and interday accuracy ranged from -11.73 to 8.92%. The limits of quantification were established at 0.005μg/mL for GAT, 0.02μg/mL for LEV, PAZ and MOX and 0.04μg/mL for TRO. No endogenous or tested exogenous compounds were found to interfere at the retention times of the analytes and IS. Since the proposed method proved to be reliable for the quantitative determination of LEV, PAZ, GAT, MOX and TRO it may be a useful tool for routine analysis and to support clinical pharmacokinetic and toxicological studies involving these antibiotics. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Influence of drying method on the surface energy of cellulose nanofibrils determined by inverse gas chromatography

    Science.gov (United States)

    Yucheng Peng; Douglas J. Gardner; Yousoo Han; Zhiyong Cai; Mandla A. Tshabalala

    2013-01-01

    Research and development of the renewable nanomaterial cellulose nanofibrils (CNFs) has received considerable attention. The effect of drying on the surface energy of CNFs was investigated. Samples of nanofibrillated cellulose (NFC) and cellulose nanocrystals (CNC) were each subjected to four separate drying methods: air-drying, freeze-drying, spray-drying, and...

  4. Molar mass determination of lignins by size-exclusion chromatography: towards standardisation of the method

    NARCIS (Netherlands)

    Baumberger, S.; Abaecherli, A.; Fasching, M.; Gellerstedt, G.; Gosselink, R.J.A.; Hortling, B.; Li, J.; Saake, B.; Jong, de E.

    2007-01-01

    The reactivity and physicochemical properties of lignins are partly governed by their molar mass distribution. The development of reliable standard methods for determination of the molar mass distribution is not only relevant for designing technical lignins for specific applications, but also for

  5. Recent developments in comprehensive two-dimensional gas chromatography (GC X GC) I. Introduction and instrumental set-up

    NARCIS (Netherlands)

    Adahchour, M.; Beens, J.; Vreuls, R.J.J.; Brinkman, U.A.T.

    2006-01-01

    We review the literature on comprehensive two-dimensional gas chromatography (GC × GC), emphasizing developments in the period 2003-2005. The review opens with a general introduction, the principles of the technique and the set-up of GC × GC systems. It also discusses theoretical aspects, trends in

  6. A general screening method for doping agents in human urine by solid phase extraction and liquid chromatography/time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kolmonen, Marjo [Forensic Toxicology Division, Department of Forensic Medicine, University of Helsinki (Finland) and Doping Control Laboratory, United Laboratories Ltd., Helsinki (Finland)]. E-mail: marjo.kolmonen@helsinki.fi; Leinonen, Antti [Doping Control Laboratory, United Laboratories Ltd., Helsinki (Finland); Pelander, Anna [Forensic Toxicology Division, Department of Forensic Medicine, University of Helsinki (Finland); Ojanperae, Ilkka [Forensic Toxicology Division, Department of Forensic Medicine, University of Helsinki (Finland)

    2007-02-28

    A general screening method based on solid phase extraction (SPE) and liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) was developed and investigated with 124 different doping agents, including stimulants, {beta}-blockers, narcotics, {beta}{sub 2}-adrenergic agonists, agents with anti-estrogenic activity, diuretics and cannabinoids. Mixed mode cation exchange/C8 cartridges were applied to SPE, and chromatography was based on gradient elution on a C18 column. Ionization of the analytes was achieved with electrospray ionization in the positive mode. Identification by LC/TOFMS was based on retention time, accurate mass and isotopic pattern. Validation of the method consisted of analysis of specificity, analytical recovery, limit of detection and repeatability. The minimum required performance limit (MRPL), established by World Anti-Doping Agency (WADA), was attained to 97 doping agents. The extraction recoveries varied between 33 and 98% and the median was 58%. Mass accuracy was always better than 5 ppm, corresponding to a maximum mass error of 0.7 mDa. The repeatability of the method for spiked urine samples, expressed as median of relative standard deviations (RSD%) at concentrations of MRPL and 10 times MRPL, were 14% and 9%, respectively. The suitability of the LC/TOFMS method for doping control was demonstrated with authentic urine samples.

  7. Liquid chromatography-tandem mass spectrometry method for determination of panel of neurotransmitters in cerebrospinal fluid from the rat model for tauopathy.

    Science.gov (United States)

    Kovac, Andrej; Somikova, Zuzana; Zilka, Norbert; Novak, Michal

    2014-02-01

    Alzheimer's disease (AD) is still being recognized today as an unmet medical need. Currently, there is no cure and early preclinical diagnostic assay available for AD. Therefore much attention is now being directed at the development of novel methods for quantitative determination of AD biomarkers in the cerebrospinal fluid (CSF). Here, we describe the liquid chromatography-tandem mass spectrometry method for determination of 5-hydroxytryptamine (SER), 5-hydroxyindoleacetic acid (5-HIAA), homovanilic acid (HVA), noradrenaline (NADR), adrenaline (ADR), dopamine (DA), glutamic acid (Glu), γ-aminobutyric acid (GABA), 3,4-dihydroxyphenylacetic acid (DOPAC) and histamine (HIS) in cerebrospinal fluid (CSF) from the rat model for human tauopathy. The benzoyl chloride was used as pre-column derivatization reagents. Neurotransmitters and metabolites were analysed on ultra performance liquid chromatography (UPLC) on C18 column in combination with tandem mass spectrometry. The method is simple, highly sensitive and showed excellent linearity with regression coefficients higher than 0.99. The accuracy was in a range of 93-113% for all analytes. The inter-day precision (n=5 days), expressed as %RSD, was in a range 2-10% for all analytes. Using this method we detected significant changes of CSF levels of two important neurotransmitters/metabolites, ADR and 5-HIAA, which correlates with progression of neurodegeneration in our animal model. © 2013 Published by Elsevier B.V.

  8. Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples

    NARCIS (Netherlands)

    Lorenzo, M.; Campo, J.; Picó, Y.

    2016-01-01

    Few methods are available for comprehensive organophosphate flame retardants (PFRs) detection in water and wastewater. Gas chromatography has been employed previously, but this approach is less selective, not amenable for use with deuterated standards and can suffer unfavorable fragmentation.

  9. METHOD 332.0: DETERMINATION OF PERCHLORATE IN DRINKING WATER BY ION CHROMATOGRAPHY WITH SUPPRESSED CONDUCTIVITY AND ELECTROSPRAY IONIZATION MASS SPECTROMETRY

    Science.gov (United States)

    This method is applicable to the identification and quantitation of perchlorate in raw and finished drinking waters. The approach used is ion chromatography with suppressed conductivity and electrospray ionization mass spectrometry (IC-ESI/MS)

  10. EPA Method 8321B (SW-846): Solvent-Extractable Nonvolatile Compounds by High Performance Liquid Chromatography-Thermospray-Mass Spectrometry (HPLC-TS-MS) or Ultraviolet (UV) Detection

    Science.gov (United States)

    Method 8321B describes procedures for preparation and analysis of solid, aqueous liquid, drinking water and wipe samples using high performance liquid chromatography and mass spectrometry for extractable non-volatile compounds.

  11. Determination of vegetable oils and fats adulterants in diesel oil by high performance liquid chromatography and multivariate methods.

    Science.gov (United States)

    Brandão, Luiz Filipe Paiva; Braga, Jez Willian Batista; Suarez, Paulo Anselmo Ziani

    2012-02-17

    The current legislation requires the mandatory addition of biodiesel to all Brazilian road diesel oil A (pure diesel) marketed in the country and bans the addition of vegetable oils for this type of diesel. However, cases of irregular addition of vegetable oils directly to the diesel oil may occur, mainly due to the lower cost of these raw materials compared to the final product, biodiesel. In Brazil, the situation is even more critical once the country is one of the largest producers of oleaginous products in the world, especially soybean, and also it has an extensive road network dependent on diesel. Therefore, alternatives to control the quality of diesel have become increasingly necessary. This study proposes an analytical methodology for quality control of diesel with intention to identify and determine adulterations of oils and even fats of vegetable origin. This methodology is based on detection, identification and quantification of triacylglycerols on diesel (main constituents of vegetable oils and fats) by high performance liquid chromatography in reversed phase with UV detection at 205nm associated with multivariate methods. Six different types of oils and fats were studied (soybean, frying oil, corn, cotton, palm oil and babassu) and two methods were developed for data analysis. The first one, based on principal component analysis (PCA), nearest neighbor classification (KNN) and univariate regression, was used for samples adulterated with a single type of oil or fat. In the second method, partial least square regression (PLS) was used for the cases where the adulterants were mixtures of up to three types of oils or fats. In the first method, the techniques of PCA and KNN were correctly classified as 17 out of 18 validation samples on the type of oil or fat present. The concentrations estimated for adulterants showed good agreement with the reference values, with mean errors of prediction (RMSEP) ranging between 0.10 and 0.22% (v/v). The PLS method was

  12. Validation of a High-Performance Liquid Chromatography method for the determination of vitamin A, vitamin D3, vitamin E and benzyl alcohol in a veterinary oily injectable solution

    OpenAIRE

    Maria Neagu; Georgiana Soceanu; Ana Caterina Bucur

    2015-01-01

    A new simple, rapid, accurate and precise high – performance liquid chromatography (HPLC) method for determination of vitamin A, vitamin D3, vitamin E and benzyl alcohol in oily injectable solution was developed and validated. The method can be used for the detection and quantification of known and unknown impurities and degradants in the drug substance during routine analysis and also for stability studies in view of its capability to separate degradation products. The method was validate...

  13. Marker based standardization of polyherbal formulation (SJT-DI-02 by high performance thin layer chromatography method

    Directory of Open Access Journals (Sweden)

    Bhakti J Ladva

    2014-01-01

    purity of the bands due to marker compounds in the sample extracts were confirmed by overlaying the absorption spectra recorded at start, middle and end position of the band in the sample tracks. After conforming all these things fingerprints were developed for all three formulations which will be act as authentification and quality control tool. Results: % w/w of asarones is 3.61, % w/w of marmelosin is 4.60, % w/w of gallic acid is 10.80 and % w/w of lupeol is 4.13.The method was validated in terms of linearity, precision, repeatability, limit of detection, limit of quantification and accuracy. In well-developed mobile phase system linearity was found to be in the range of 0.983-0.995, % recovery was found to be in the range of 97.48-99.63, % RSD for intraday and interday was found to be 0.13- 0.70 and 0.32 -1.41 and LOD and LOQ was found to be in the range of 0.15- 0.61 and 0.45 -1.83 microgram per ml. Conclusion: Thus High performance thin layer chromatography (HPTLC methods were developed and validated in terms of linearity, precision, repeatability, limit of detection, limit of quantification and accuracy. The methods were rapid, sensitive, reproducible and economical. It does not suffer any positive or negative interference due to common other component present in the formulation and would also serve as a tool for authentication of herbal products containing marmelosin, gallic acid, lupeol and asarones. Thus this work provides standardized and therapeutically active polyherbal formulations for the different ailments.

  14. Quantitative bioanalytical and analytical method development of dibenzazepine derivative, carbamazepine: A review ☆

    OpenAIRE

    Datar, Prasanna A.

    2015-01-01

    Bioanalytical methods are widely used for quantitative estimation of drugs and their metabolites in physiological matrices. These methods could be applied to studies in areas of human clinical pharmacology and toxicology. The major bioanalytical services are method development, method validation and sample analysis (method application). Various methods such as GC, LC–MS/MS, HPLC, HPTLC, micellar electrokinetic chromatography, and UFLC have been used in laboratories for the qualitative and qua...

  15. Surface enhanced Raman scattering imaging of developed thin-layer chromatography plates.

    Science.gov (United States)

    Freye, Chris E; Crane, Nichole A; Kirchner, Teresa B; Sepaniak, Michael J

    2013-04-16

    A method for hyphenating surface enhanced Raman scattering (SERS) and thin-layer chromatography (TLC) is presented that employs silver-polymer nanocomposites as an interface. Through the process of conformal blotting, analytes are transferred from TLC plates to nanocomposite films before being imaged via SERS. A procedure leading to maximum blotting efficiency was established by investigating various parameters such as time, pressure, and type and amount of blotting solvent. Additionally, limits of detection were established for test analytes malachite green isothiocyanate, 4-aminothiophenol, and Rhodamine 6G (Rh6G) ranging from 10(-7) to 10(-6) M. Band broadening due to blotting was minimal (∼10%) as examined by comparing the spatial extent of TLC-spotted Rh6G via fluorescence and then the SERS-based spot size on the nanocomposite after the blotting process. Finally, a separation of the test analytes was carried out on a TLC plate followed by blotting and the acquisition of distance × wavenumber × intensity three-dimensional TLC-SERS plots.

  16. Solid-phase microextraction/gas chromatography-mass spectrometry method optimization for characterization of surface adsorption forces of nanoparticles.

    Science.gov (United States)

    Omanovic-Miklicanin, Enisa; Valzacchi, Sandro; Simoneau, Catherine; Gilliland, Douglas; Rossi, Francois

    2014-10-01

    A complete characterization of the different physico-chemical properties of nanoparticles (NPs) is necessary for the evaluation of their impact on health and environment. Among these properties, the surface characterization of the nanomaterial is the least developed and in many cases limited to the measurement of surface composition and zetapotential. The biological surface adsorption index approach (BSAI) for characterization of surface adsorption properties of NPs has recently been introduced (Xia et al. Nat Nanotechnol 5:671-675, 2010; Xia et al. ACS Nano 5(11):9074-9081, 2011). The BSAI approach offers in principle the possibility to characterize the different interaction forces exerted between a NP's surface and an organic--and by extension biological--entity. The present work further develops the BSAI approach and optimizes a solid-phase microextraction gas chromatography-mass spectrometry (SPME/GC-MS) method which, as an outcome, gives a better-defined quantification of the adsorption properties on NPs. We investigated the various aspects of the SPME/GC-MS method, including kinetics of adsorption of probe compounds on SPME fiber, kinetic of adsorption of probe compounds on NP's surface, and optimization of NP's concentration. The optimized conditions were then tested on 33 probe compounds and on Au NPs (15 nm) and SiO2 NPs (50 nm). The procedure allowed the identification of three compounds adsorbed by silica NPs and nine compounds by Au NPs, with equilibrium times which varied between 30 min and 12 h. Adsorption coefficients of 4.66 ± 0.23 and 4.44 ± 0.26 were calculated for 1-methylnaphtalene and biphenyl, compared to literature values of 4.89 and 5.18, respectively. The results demonstrated that the detailed optimization of the SPME/GC-MS method under various conditions is a critical factor and a prerequisite to the application of the BSAI approach as a tool to characterize surface adsorption properties of NPs and therefore to draw any further

  17. Method Optimization for Rapid Measurement of Carbohydrates in Plasma by Liquid Chromatography Tandem Mass Spectrometry

    International Nuclear Information System (INIS)

    Nguyen, Ductoan; Yu, Jondong; Mho, Sunil; Lee, Gwang; Lee, Haelee; Paik, Manjeong; Yee, Sungtae

    2013-01-01

    In conclusion, the developed HPLC coupled with ESI-MS was a powerful technique for the separation and characterization of carbohydrates by either SIM or MRM mode. The present method will be useful for the monitoring of carbohydrate profile in biological fluids from various diseases including diabetic ketoacidosis, hypoglycemia and hyperosmolar coma. Carbohydrates are one of the most abundant classes of organic compounds in nature, which not only constitute complex biomolecules in human and animals but are also distributed in plants and bacteria

  18. A novel method for selective separation of {sup 111}In from impurities by ion exchange chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Yavari, R.; Khanachi, A.R.; Ghannad Maragheh, M.; Bagheri, G. [Jaber Ibn-e Hayan Research Laboratories, A.E.O.I., Tehran (Iran)

    2004-07-01

    {sup 111}In is one of the most important cyclotron-produced radionuclides that is prepared from nuclear reactions like Cd (p,xn){sup 111}In and Cd (d,xn) {sup 111}In. It is used in various branches of medicine such as lymphoscintigraphy and cisternography. Several methods have been reported in the literature for the separation of carrier-free {sup 111}In from irradiated cadmium matrix. But there has not been a sufficiently fast method for this purpose until recently. In this work, a new method has been developed for the separation of {sup 111}In from a cadmium target by using Dowex 50W-X8 as an ion exchanger. (orig.)

  19. Direct liquid chromatography method for the simultaneous quantification of hydroxytyrosol and tyrosol in red wines.

    Science.gov (United States)

    Piñeiro, Zulema; Cantos-Villar, Emma; Palma, Miguel; Puertas, Belen

    2011-11-09

    A validated HPLC method with fluorescence detection for the simultaneous quantification of hydroxytyrosol and tyrosol in red wines is described. Detection conditions for both compounds were optimized (excitation at 279 and 278 and emission at 631 and 598 nm for hydroxytyrosol and tyrosol, respectively). The validation of the analytical method was based on selectivity, linearity, robustness, detection and quantification limits, repeatability, and recovery. The detection and quantification limits in red wines were set at 0.023 and 0.076 mg L(-1) for hydroxytyrosol and at 0.007 and 0.024 mg L(-1) for tyrosol determination, respectively. Precision values, both within-day and between-day (n = 5), remained below 3% for both compounds. In addition, a fractional factorial experimental design was developed to analyze the influence of six different conditions on analysis. The final optimized HPLC-fluorescence method allowed the analysis of 30 nonpretreated Spanish red wines to evaluate their hydroxytyrosol and tyrosol contents.

  20. A novel liquid chromatography/mass spectrometry method for determination of neurotransmitters in brain tissue: Application to human tauopathies.

    Science.gov (United States)

    Forgacsova, Andrea; Galba, Jaroslav; Garruto, Ralph M; Majerova, Petra; Katina, Stanislav; Kovac, Andrej

    2018-01-15

    Neurotransmitters, small molecules widely distributed in the central nervous system are essential in transmitting electrical signals across neurons via chemical communication. Dysregulation of these chemical signaling molecules is linked to numerous neurological diseases including tauopathies. In this study, a precise and reliable liquid chromatography method was established with tandem mass spectrometry detection for the simultaneous determination of aspartic acid, asparagine, glutamic acid, glutamine, γ-aminobutyric acid, N-acetyl-l-aspartic acid, pyroglutamic acid, acetylcholine and choline in human brain tissue. The method was successfully applied to the analysis of human brain tissues from three different tauopathies; corticobasal degeneration, progressive supranuclear palsy and parkinsonism-dementia complex of Guam. Neurotransmitters were analyzed on ultra-high performance chromatography (UHPLC) using an ethylene bridged hybrid amide column coupled with tandem mass spectrometry (MS/MS). Identification and quantification of neurotransmitters was carried out by ESI+ mass spectrometry detection. We optimized sample preparation to achieve simple and fast extraction of all nine analytes. Our method exhibited an excellent linearity for all analytes (all coefficients of determination >0.99), with inter-day and intra-day precision yielding relative standard deviations 3.2%-11.2% and an accuracy was in range of 92.6%-104.3%. The present study, using the above method, is the first to demonstrate significant alterations of brain neurotransmitters caused by pathological processes in the brain tissues of patient with three different tauopathies. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Analysis of Trace Pharmaceuticals and Related Compounds in Municipal Wastewaters by Preconcentration, Chromatography, Derivatization, and Separation Methods

    Directory of Open Access Journals (Sweden)

    Petra Camilla Lindholm

    2014-05-01

    Full Text Available A significant portion of pharmaceuticals and other organic chemicals consumed by people and animals are released into municipal wastewater treatment plants. Most of them are degraded during the wastewater treatment processes, but some of them degrade only partially and may be widely transported and dispersed into the aquatic environment. This is why efficient and fast analytical methods are needed for detection of organic compounds in wastewaters at trace levels. Because wastewaters often consist of complex matrices and high-molecular mass materials, e.g., lignocellulosic biomass, which may bring challenges to the sample preparation procedures, efficient pre-concentration methods such as solid phase extraction (SPE solid phase microextraction (SPME, or single drop microextraction (SDME are needed. The most common analysis methods are gas chromatography (GC and liquid chromatography (LC coupled with tandem mass spectrometry (MS/MS. The aim of this review is to give an overview of chromatographic and spectroscopic methods when characterizing low- and medium-molecular weight organic pollutants, mainly focusing on pharmaceuticals, biocides, and personal care products in environmental matrices.

  2. Development of a gas chromatography-mass spectrometry technique to diagnose white snakeroot (Ageratina altissima) poisoning in a cow.

    Science.gov (United States)

    Meyerholtz, Kimberly A; Burcham, Grant N; Miller, Margaret A; Wilson, Christina R; Hooser, Stephen B; Lee, Stephen T

    2011-07-01

    An 8-year-old, crossbred beef cow was referred to the Indiana Animal Disease Diagnostic Laboratory at Purdue University for a complete necropsy in October 2009. The cow was the sixth to die in a 7-day period. Affected cows were reportedly stumbling and became weak, excitable, and recumbent. Histologically, myonecrosis was severe in the skeletal muscles and mild in the heart and tongue. According to the submitter, exposure to a poisonous plant was suspected, and a plant specimen received from this case was identified as white snakeroot (Ageratina altissima). Using the white snakeroot specimen, a gas chromatography-mass spectrometry analytical method for the detection of tremetone and dehydrotremetone (2 components of white snakeroot) was developed. Both tremetone and dehydrotremetone were detected in the plant specimen. Dehydrotremetone was recovered from the liver, while neither component was recovered in the rumen content. In the past, because of the lack of standard reference material, the diagnosis of white snakeroot poisoning was based mainly on history of exposure and the presence of the plant in the rumen. The analytical method described herein can be used to document exposure to tremetone or dehydrotremetone in cases of suspected white snakeroot poisoning when coupled with the appropriate clinical signs and lesions.

  3. Sensitive, automatic method for the determination of diazepam and its five metabolites in human oral fluid by online solid-phase extraction and liquid chromatography with tandem mass spectrometry

    DEFF Research Database (Denmark)

    Jiang, Fengli; Rao, Yulan; Wang, Rong

    2016-01-01

    A novel and simple online solid-phase extraction liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous determination of diazepam and its five metabolites including nordazepam, oxazepam, temazepam, oxazepam glucuronide, and temazepam glucuronide...... in human oral fluid. Human oral fluid was obtained using the Salivette(®) collection device, and 100 μL of oral fluid samples were loaded onto HySphere Resin GP cartridge for extraction. Analytes were separated on a Waters Xterra C18 column and quantified by liquid chromatography with tandem mass...

  4. Gas chromatography

    International Nuclear Information System (INIS)

    Cram, S.P.; Risby, T.H.; Field, L.R.; Yu, W.L.

    1980-01-01

    In addition to the published literature for the years 1978 - 79, this review of developments in the field of gas chromatography includes earlier articles of particular significance appearing in foreign journals and the patent literature which was not available at the time of the previous review. The articles cited were selected as presenting the most fundamental developments in theory, methodology, and instrumentation. Some applications are cited if they reflect an advance in the state-of-the-art or have particular relevance to new developments. 1149 references are cited

  5. A candidate liquid chromatography mass spectrometry reference method for the quantification of the cardiac marker 1-32 B-type natriuretic peptide.

    Science.gov (United States)

    Torma, Attila F; Groves, Kate; Biesenbruch, Sabine; Mussell, Chris; Reid, Alan; Ellison, Steve; Cramer, Rainer; Quaglia, Milena

    2017-08-28

    B-type natriuretic peptide (BNP) is a 32 amino acid cardiac hormone routinely measured by immunoassays to diagnose heart failure. While it is reported that immunoassay results can vary up to 45%, no attempt of standardization and/or harmonization through the development of certified reference materials (CRMs) or reference measurement procedures (RMPs) has yet been carried out. B-type natriuretic peptide primary calibrator was quantified traceably to the International System of Units (SI) by both amino acid analysis and tryptic digestion. A method for the stabilization of BNP in plasma followed by protein precipitation, solid phase extraction (SPE) and liquid chromatography (LC) mass spectrometry (MS) was then developed and validated for the quantification of BNP at clinically relevant concentrations (15-150 fmol/g). The candidate reference method was applied to the quantification of BNP in a number of samples from the UK NEQAS Cardiac Markers Scheme to demonstrate its applicability to generate reference values and to preliminary evaluate the commutability of a potential CRM. The results from the reference method were consistently lower than the immunoassay results and discrepancy between the immunoassays was observed confirming previous data. The application of the liquid chromatography-mass spectrometry (LC-MS) method to the UK NEQAS samples and the correlation of the results with the immunoassay results shows the potential of the method to support external quality assessment schemes, to improve understanding of the bias of the assays and to establish RMPs for BNP measurements. Furthermore, the method has the potential to be multiplexed for monitoring circulating truncated forms of BNP.

  6. A liquid chromatography – tandem mass spectrometry method to measure a selected panel of uremic retention solutes derived from endogenous and colonic microbial metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Loor, Henriette de; Poesen, Ruben [KU Leuven – University of Leuven, Department of Microbiology and Immunology, Laboratory of Nephrology, B-3000 Leuven (Belgium); De Leger, Wout; Dehaen, Wim [KU Leuven – University of Leuven, Department of Chemistry, Division of Molecular Design and Synthesis, B-3000 Leuven (Belgium); Augustijns, Patrick [KU Leuven – University of Leuven, Department of Pharmaceutical and Pharmacological Sciences, Drug Delivery and Disposition, B-3000 Leuven (Belgium); Evenepoel, Pieter [KU Leuven – University of Leuven, Department of Microbiology and Immunology, Laboratory of Nephrology, B-3000 Leuven (Belgium); University Hospitals Leuven, Department of Nephrology and Renal Transplantation, B-3000 Leuven (Belgium); Meijers, Björn, E-mail: bjorn.meijers@uzleuven.be [KU Leuven – University of Leuven, Department of Microbiology and Immunology, Laboratory of Nephrology, B-3000 Leuven (Belgium); University Hospitals Leuven, Department of Nephrology and Renal Transplantation, B-3000 Leuven (Belgium)

    2016-09-14

    Chronic kidney disease (CKD) is associated with an increased risk of mortality and cardiovascular disease, which is, at least partly, mediated by the accumulation of so-called uremic retention solutes. Although there has been an increasing interest in the behavior of these solutes, derived from both the endogenous and colonic microbial metabolism, methods to simultaneously and accurately measure a broad panel of relevant uremic retention solutes remain scarce. We developed a highly sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. A high throughput sample preparation was used with extraction of analytes from 50 μl serum using Ostro plate technology. For most solutes, stable isotopes labelled metabolites were used as internal standards. Chromatography was achieved using an Acquity UPLC CSH Fluoro Phenyl column. The total run time was 8 min, the mobile phase was a gradient of 0.1% formic acid in Milli-Q water and pure methanol at a flow rate of 0.5 ml min{sup −1}. Detection was performed using a tandem mass spectrometer with alternated positive and negative electrospray ionization. Calibration curves were linear for all solutes. Precision was assessed according to the NCCLS EP5-T guideline, being below 15% for all metabolites. Mean recoveries were between 83 and 104% for all metabolites. The validated method was successfully applied in a cohort of 488 patients with CKD. We developed and validated a sensitive and robust UPLC-MS/MS method for quantification of 15 uremic retention solutes derived from endogenous and colonic microbial metabolism. This method allows for studying the behavior and relevance of these solutes in patients with CKD. - Highlights: • Simultaneous quantification of fifteen relevant uremic retention solutes. • Comprehensive validation, highly sensitive and high through-put LC-MSMS method. • Comparison of different blood tubes. • Freeze-thaw stability. • Successful implementation in a

  7. A rapid and sensitive evaluation of nitrite content in Saudi Arabian processed meat and poultry using a novel ultra performance liquid chromatography-mass spectrometry method.

    Science.gov (United States)

    Siddiqui, Masoom Raza; Wabaidur, Saikh Mohammad; Khan, Moonis Ali; ALOthman, Zeid A; Rafiquee, M Z A; Alqadami, Ayoub Abdullah

    2018-01-01

    Quantitative assessment of nitrite (NO 2 - ) anion was performed using a newly developed high throughput ultra performance liquid chromatography-mass spectrometric (UPLC-MS) method. The nitrite determination with the proposed method using micellar mobile phase was unknown. Selected ion reaction mode using negative electrospray ionization was adopted for the identification and quantitative analysis of nitrite. The chromatographic separation was performed using BEH C-18 column and a micellar mobile phase consisted of sodium dodecyl sulphate and acetonitrile in ratio 30:70 was used. The elution of nitrite anion was accomplished in less than 1 min. Under the optimal analysis conditions, the linearity of the developed method was checked in the concentration range of 0.5-20 mg kg -1 NO 2 - with an excellent correlation coefficient of 0.996. The precisions of the method with relative standard deviation <2% was observed when standard at concentration of 1 mg kg -1 was used. The limit of detection and limit of quantitation of the developed mass spectrometric method was found to be 0.114 and 0.346 mg kg -1 , respectively. The developed UPLC/MS method was applied to quantify this anion in processed meats and poultries from various super market of Saudi Arabia (Riyadh region). The recoveries of the nitrite in the various samples were found in the range of 100.03-103.5%.

  8. Quantitative bioanalytical and analytical method development of dibenzazepine derivative, carbamazepine: A review

    Directory of Open Access Journals (Sweden)

    Prasanna A. Datar

    2015-08-01

    Full Text Available Bioanalytical methods are widely used for quantitative estimation of drugs and their metabolites in physiological matrices. These methods could be applied to studies in areas of human clinical pharmacology and toxicology. The major bioanalytical services are method development, method validation and sample analysis (method application. Various methods such as GC, LC–MS/MS, HPLC, HPTLC, micellar electrokinetic chromatography, and UFLC have been used in laboratories for the qualitative and quantitative analysis of carbamazepine in biological samples throughout all phases of clinical research and quality control. The article incorporates various reported methods developed to help analysts in choosing crucial parameters for new method development of carbamazepine and its derivatives and also enumerates metabolites, and impurities reported so far. Keywords: Carbamazepine, HPLC, LC–MS/MS, HPTLC, RP-UFLC, Micellar electrokinetic chromatography

  9. Rapid and accurate liquid chromatography and tandem mass spectrometry method for the simultaneous quantification of ten metabolic reactions catalyzed by hepatic cytochrome P450 enzymes.

    Science.gov (United States)

    Shi, Rong; Ma, Bingliang; Wu, Jiasheng; Wang, Tianming; Ma, Yueming

    2015-10-01

    The hepatic cytochrome P450 enzymes play a central role in the biotransformation of endogenous and exogenous substances. A sensitive high-throughput liquid chromatography with tandem mass spectrometry assay was developed and validated for the simultaneous quantification of the products of ten metabolic reactions catalyzed by hepatic cytochrome P450 enzymes. After the substrates were incubated separately, the samples were pooled and analyzed by liquid chromatography with tandem mass spectrometry using an electrospray ionization source in the positive and negative ion modes. The method exhibited linearity over a broad concentration range, insensitivity to matrix effects, and high accuracy, precision, and stability. The novel method was successfully applied to study the kinetics of phenacetin-O deethylation, coumarin-7 hydroxylation, bupropion hydroxylation, taxol-6 hydroxylation, omeprazole-5 hydroxylation, dextromethorphan-O demethylation, tolbutamide-4 hydroxylation, chlorzoxazone-6 hydroxylation, testosterone-6β hydroxylation, and midazolam-1 hydroxylation in rat liver microsomes. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Multiclass method for the quantification of 92 veterinary antimicrobial drugs in livestock excreta, wastewater, and surface water by liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Gao, Jinfang; Cui, Yonghui; Tao, Yanfei; Huang, Lingli; Peng, Dapeng; Xie, Shuyu; Wang, Xu; Liu, Zhenli; Chen, Dongmei; Yuan, Zonghui

    2016-11-01

    A simple multiresidue method was developed for detecting and quantifying 92 veterinary antimicrobial drugs from eight classes (β-lactams, quinolones, sulfonamides, tetracyclines, lincomycins, macrolides, chloramphenicols, and pleuromutilin) in livestock excreta and water by liquid chromatography with tandem mass spectrometry. The feces samples were extracted by ultrasound-assisted extraction with a mixture of acetonitrile/water (80:20, v/v) and edetate disodium, followed by a cleanup using solid-phase extraction with an amino cartridge. Water samples were purified with hydrophilic-lipophilic balance solid-phase extraction column. Urine samples were extracted with acetonitrile and edetate disodium. Detection of veterinary antimicrobial drugs was achieved by liquid chromatography with tandem mass spectrometry using both positive and negative electrospray ionization mode. The recovery values of veterinary antimicrobial drugs in feces, urine, and water samples were 75-99, 85-110, and 85-101% and associated relative standard deviations were less than 15, 10, and 8%, respectively. The limits of quantification in feces, urine, and water samples were 0.5-1, 0.5-1, and 0.01-0.05 μg/L, respectively. This method was applied to determine real samples obtained from local farms and provides reliable quantification and identification results of 92 veterinary antimicrobial drugs in livestock excreta and water. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Novel materials and methods for solid-phase extraction and liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Ambrose, Diana [Iowa State Univ., Ames, IA (United States)

    1997-06-24

    This report contains a general introduction which discusses solid-phase extraction and solid-phase micro-extraction as sample preparation techniques for high-performance liquid chromatography, which is also evaluated in the study. This report also contains the Conclusions section. Four sections have been removed and processed separately: silicalite as a sorbent for solid-phase extraction; a new, high-capacity carboxylic acid functionalized resin for solid-phase extraction; semi-micro solid-phase extraction of organic compounds from aqueous and biological samples; and the high-performance liquid chromatographic determination of drugs and metabolites in human serum and urine using direct injection and a unique molecular sieve.

  12. Quantification of imatinib in human serum: validation of a high-performance liquid chromatography-mass spectrometry method for therapeutic drug monitoring and pharmacokinetic assays

    Directory of Open Access Journals (Sweden)

    Rezende VM

    2013-08-01

    Full Text Available Vinicius Marcondes Rezende,1 Ariane Rivellis,1 Mafalda Megumi Yoshinaga Novaes,1 Dalton de Alencar Fisher Chamone,2 Israel Bendit1,21Laboratory of Tumor Biology, 2Department of Hematology, School of Medicine, University of São Paulo, São Paulo, BrazilBackground: Imatinib mesylate has been a breakthrough treatment for chronic myeloid leukemia. It has become the ideal tyrosine kinase inhibitor and the standard treatment for chronic-phase leukemia. Striking results have recently been reported, but intolerance to imatinib and noncompliance with treatment remain to be solved. Molecular monitoring by quantitative real-time polymerase chain reaction is the gold standard for monitoring patients, and imatinib blood levels have also become an important tool for monitoring.Methods: A fast and cheap method was developed and validated using high-performance liquid chromatography-mass spectrometry for quantification of imatinib in human serum and tamsulosin as the internal standard. Remarkable advantages of the method includes use of serum instead of plasma, less time spent on processing and analysis, simpler procedures, and requiring reduced amounts of biological material, solvents, and reagents. Stability of the analyte was also studied. This research also intended to drive the validation scheme in clinical centers. The method was validated according to the requirements of the US Food and Drug Administration and Brazilian National Health Surveillance Agency within the range of 0.500–10.0 µg/mL with a limit of detection of 0.155 µg/mL. Stability data for the analyte are also presented.Conclusion: Given that the validated method has proved to be linear, accurate, precise, and robust, it is suitable for pharmacokinetic assays, such as bioavailability and bioequivalence, and is being successfully applied in routine therapeutic drug monitoring in the hospital service.Keywords: imatinib, high-performance liquid chromatography-mass spectrometry, therapeutic

  13. Validation of high-performance liquid chromatography (HPLC method for quantitative analysis of histamine in fish and fishery products

    Directory of Open Access Journals (Sweden)

    B.K.K.K. Jinadasa

    2016-12-01

    Full Text Available A high-performance liquid chromatography method is described for quantitative determination and validation of histamine in fish and fishery product samples. Histamine is extracted from fish/fishery products by homogenizing with tri-chloro acetic acid, separated with Amberlite CG-50 resin and C18-ODS Hypersil reversed phase column at ambient temperature (25°C. Linear standard curves with high correlation coefficients were obtained. An isocratic elution program was used; the total elution time was 10 min. The method was validated by assessing the following aspects; specificity, repeatability, reproducibility, linearity, recovery, limits of detection, limit of quantification and uncertainty. The validated parameters are in good agreement with method and it is a useful tool for determining histamine in fish and fishery products.

  14. Comparative investigation of the gel chromatography column scanning method for quality control of /sup 99/sup(m)Tc-methylenediphosphonate

    Energy Technology Data Exchange (ETDEWEB)

    Darte, L

    1981-04-01

    Gel chromatography column scanning (GCS) is the method of choice for quality control of sup(99m)Tc-MDP preparations. Using this method all the labelled components are obtained rapidly in one simple test procedure. The influence of various parameters such as gel type, column size, prehistory of column, equilibration, eluent, elution volume and flow rate upon the results have been investigated. Test results for sup(99 m)Tc-MDP have been compared for several different GCS systems, a few TLC systems and column chromatography with fraction collection. The GCS technique, optimized for testing sup(99m)Tc-MDP preparations has been applied in a few experiments in which very good reproducibility is required: Labelling kinetics and stability when stored at room temperature or in a refrigerator and influence of the sup(99m)Te/(sup(99m)Tc + /sup 99/Tc) atomic ratio and of the amount of radioactivity on the sup(99m)Tc-MDP labelling yield, covering parameter ranges of clinical interest, have been studied.

  15. Method optimization for drug impurity profiling in supercritical fluid chromatography: Application to a pharmaceutical mixture.

    Science.gov (United States)

    Muscat Galea, Charlene; Didion, David; Clicq, David; Mangelings, Debby; Vander Heyden, Yvan

    2017-12-01

    A supercritical chromatographic method for the separation of a drug and its impurities has been developed and optimized applying an experimental design approach and chromatogram simulations. Stationary phase screening was followed by optimization of the modifier and injection solvent composition. A design-of-experiment (DoE) approach was then used to optimize column temperature, back-pressure and the gradient slope simultaneously. Regression models for the retention times and peak widths of all mixture components were built. The factor levels for different grid points were then used to predict the retention times and peak widths of the mixture components using the regression models and the best separation for the worst separated peak pair in the experimental domain was identified. A plot of the minimal resolutions was used to help identifying the factor levels leading to the highest resolution between consecutive peaks. The effects of the DoE factors were visualized in a way that is familiar to the analytical chemist, i.e. by simulating the resulting chromatogram. The mixture of an active ingredient and seven impurities was separated in less than eight minutes. The approach discussed in this paper demonstrates how SFC methods can be developed and optimized efficiently using simple concepts and tools. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Method for the Determination of Ammonia in Mainstream Cigarette Smoke Using Ion Chromatography.

    Directory of Open Access Journals (Sweden)

    Christina Vaughan Watson

    Full Text Available Ammonia in mainstream smoke is present in both the particulate and vapor phases. The presence of ammonia in the cigarette filler material and smoke is of significance because of the potential role ammonia could have in raising the "smoke pH." An increased smoke pH could shift a fraction of total nicotine to free-base nicotine, which is reportedly more rapidly absorbed by the smoker. Methods measuring ammonia in smoke typically employ acid filled impingers to trap the smoke. We developed a fast, reliable method to measure ammonia in mainstream smoke without the use of costly and time consuming impingers to examine differences in ammonia delivery. The method uses both a Cambridge filter pad and a Tedlar bag to capture particulate and vapor phases of the smoke. We quantified ammonia levels in the mainstream smoke of 50 cigarette brands from 5 manufacturers. Ammonia levels ranged from approximately 1μg to 23μg per cigarette for ISO smoking conditions and 38μg to 67μg per cigarette for Canadian intense smoking conditions and statistically significance differences were observed between brands and manufacturers. Our findings suggest that ammonia levels vary by brand and are higher under Canadian intense smoking conditions.

  17. Liquid chromatography-tandem mass spectrometry method for the determination of thiosulfate in human blood and urine as an indicator of hydrogen sulfide poisoning.

    Science.gov (United States)

    Maseda, Chikatoshi; Hayakawa, Akira; Okuda, Katsuhiro; Asari, Masaru; Tanaka, Hiroki; Yamada, Hiromi; Jin, Shigeki; Horioka, Kie; Matoba, Kotaro; Shiono, Hiroshi; Matsubara, Kazuo; Shimizu, Keiko

    2017-01-01

    Being a stable metabolite of hydrogen sulfide, thiosulfate has been utilized as an index for hydrogen sulfide poisoning (HSP). Thiosulfate analysis is mainly performed using gas chromatography/mass spectrometry (GC-MS) due to its high sensitivity and specificity. The GC-MS analysis requires two-step derivatizations of thiosulfate, and the derivative is not stable in solution as it has a disulfide moiety. To resolve this stability issue, we developed a novel analytical method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for monitoring the pentafluorobenzyl derivative of thiosulfate (the first reaction product of the GC-MS method) in this study. The established method exhibited high reproducibility despite being a more simplified and rapid procedure compare to the GC-MS method. Phenyl 4-hydroxybenzoate was used as an internal standard because 1,3,5-tribromobenzene which had been used in the GC-MS method was not suitable compound for LC-MS/MS with Electrospray ionization (ESI) negative detection. The linear regression of the peak area ratios versus concentrations was fitted over the concentration ranges of 0.5-250μM and 0.25-250μM in blood and urine, respectively. The validation results satisfied the acceptance criteria for intra- and inter-day accuracy and precision. Blood and urine samples from 12 suspected HSP cases were tested using this method. The thiosulfate concentration detected in the sample coincided well with that determined at the scene of each HSP accident. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Hydrophilic interaction liquid chromatography-tandem mass spectrometry quantitative method for the cellular analysis of varying structures of gemini surfactants designed as nanomaterial drug carriers.

    Science.gov (United States)

    Donkuru, McDonald; Michel, Deborah; Awad, Hanan; Katselis, George; El-Aneed, Anas

    2016-05-13

    Diquaternary gemini surfactants have successfully been used to form lipid-based nanoparticles that are able to compact, protect, and deliver genetic materials into cells. However, what happens to the gemini surfactants after they have released their therapeutic cargo is unknown. Such knowledge is critical to assess the quality, safety, and efficacy of gemini surfactant nanoparticles. We have developed a simple and rapid liquid chromatography electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the quantitative determination of various structures of gemini surfactants in cells. Hydrophilic interaction liquid chromatography (HILIC) was employed allowing for a short simple isocratic run of only 4min. The lower limit of detection (LLOD) was 3ng/mL. The method was valid to 18 structures of gemini surfactants belonging to two different structural families. A full method validation was performed for two lead compounds according to USFDA guidelines. The HILIC-MS/MS method was compatible with the physicochemical properties of gemini surfactants that bear a permanent positive charge with both hydrophilic and hydrophobic elements within their molecular structure. In addition, an effective liquid-liquid extraction method (98% recovery) was employed surpassing previously used extraction methods. The analysis of nanoparticle-treated cells showed an initial rise in the analyte intracellular concentration followed by a maximum and a somewhat more gradual decrease of the intracellular concentration. The observed intracellular depletion of the gemini surfactants may be attributable to their bio-transformation into metabolites and exocytosis from the host cells. Obtained cellular data showed a pattern that grants additional investigations, evaluating metabolite formation and assessing the subcellular distribution of tested compounds. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. A new method of analysis of peroxydisulfate using ion chromatography and its application to the simultaneous determination of peroxydisulfate and other common inorganic ions in a peroxydisulfate matrix.

    Science.gov (United States)

    Khan, Nymul E; Adewuyi, Yusuf G

    2011-01-21

    A new method for the determination of peroxydisulfate using ion chromatography has been developed. Elution of peroxydisulfate was effected by isocratic elution using 200 mM NaOH at 40°C. A modification of the method using gradient elution was able to simultaneously determine other common inorganic ions (nitrate, nitrite, sulfate and chloride) down to significantly low concentrations in a peroxydisulfate matrix. The relative standard deviations (RSD) were in the range of 0.5-5%, for peak areas and ion was 0.2 ppm and for the other ions were ≤2×10(-2) ppm. The calibration curves were linear with slope and intercepts close to 1 and 0, respectively. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Green and simple analytical method to determine benzimidazoles in milk samples by using salting-out assisted liquid-liquid extraction and capillary liquid chromatography.

    Science.gov (United States)

    Tejada-Casado, Carmen; Del Olmo-Iruela, Monsalud; García-Campaña, Ana M; Lara, Francisco J

    2018-08-01

    A green and simple multiresidue method using capillary liquid chromatography (CLC) with UV-diode array detection (DAD) has been developed for the determination of sixteen benzimidazoles (BZs) and its metabolites in milk samples. The separation was achieved in  0.9985 for all BZs) with limits of detection (LOD) between 1.0 and 2.8 μg kg -1 . Relative standard deviations of repeatability and intermediate precision were below 1.6 and 14.2%, respectively. Satisfactory recoveries between 79.1 and 99.6% were also obtained for three types of milk samples (cow, sheep and goat). The advantages of a miniaturized technique such as CLC in terms of better efficiencies and reduced solvent consumption, combined with the simplicity of the SALLE procedure, make this method a useful alternative for the monitoring of these residues at trace level. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. A rapid monitoring method for inorganic arsenic in rice flour using reversed phase-high performance liquid chromatography-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Narukawa, Tomohiro; Chiba, Koichi; Sinaviwat, Savarin; Feldmann, Jörg

    2017-01-06

    A new rapid monitoring method by means of high performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) following the heat-assisted extraction was developed for measurement of total inorganic arsenic species in rice flour. As(III) and As(V) eluted at the same retention time and completely separated from organoarsenic species by an isocratic elution program on a reversed phase column. Therefore, neither ambiguous oxidation of arsenite to arsenate nor the integration of two peaks were necessary to determine directly the target analyte inorganic arsenic. Rapid injection allowed measuring 3 replicates within 6min and this combined with a quantitative extraction of all arsenic species from rice flour by a 15min HNO 3 -H 2 O 2 extraction makes this the fastest laboratory based method for inorganic arsenic in rice flour. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Comparison of Dorris-Gray and Schultz methods for the calculation of surface dispersive free energy by inverse gas chromatography.

    Science.gov (United States)

    Shi, Baoli; Wang, Yue; Jia, Lina

    2011-02-11

    Inverse gas chromatography (IGC) is an important technique for the characterization of surface properties of solid materials. A standard method of surface characterization is that the surface dispersive free energy of the solid stationary phase is firstly determined by using a series of linear alkane liquids as molecular probes, and then the acid-base parameters are calculated from the dispersive parameters. However, for the calculation of surface dispersive free energy, generally, two different methods are used, which are Dorris-Gray method and Schultz method. In this paper, the results calculated from Dorris-Gray method and Schultz method are compared through calculating their ratio with their basic equations and parameters. It can be concluded that the dispersive parameters calculated with Dorris-Gray method will always be larger than the data calculated with Schultz method. When the measuring temperature increases, the ratio increases large. Compared with the parameters in solvents handbook, it seems that the traditional surface free energy parameters of n-alkanes listed in the papers using Schultz method are not enough accurate, which can be proved with a published IGC experimental result. © 2010 Elsevier B.V. All rights reserved.

  3. Collaborative trial validation study of two methods, one based on high performance liquid chromatography-tandem mass spectrometry and on gas chromatography-mass spectrometry for the determination of acrylamide in bakery and potato products.

    Science.gov (United States)

    Wenzl, Thomas; Karasek, Lubomir; Rosen, Johan; Hellenaes, Karl-Erik; Crews, Colin; Castle, Laurence; Anklam, Elke

    2006-11-03

    A European inter-laboratory study was conducted to validate two analytical procedures for the determination of acrylamide in bakery ware (crispbreads, biscuits) and potato products (chips), within a concentration range from about 20 microg/kg to about 9000 microgg/kg. The methods are based on gas chromatography-mass spectrometry (GC-MS) of the derivatised analyte and on high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) of native acrylamide. Isotope dilution with isotopically labelled acrylamide was an integral part of both methods. The study was evaluated according to internationally accepted guidelines. The performance of the HPLC-MS/MS method was found to be superior to that of the GC-MS method and to be fit-for-the-purpose.

  4. Development and validation of a stability-indicating HPLC-UV method for the determination of triamcinolone acetonide and its degradation products in an ointment formulation

    NARCIS (Netherlands)

    van Heugten, A J P; Boer, W.; de Vries, W S; Markesteijn, C M A; Vromans, H

    2018-01-01

    A stability indicating high performance liquid chromatography method has been developed for the determination of triamcinolone acetonide (TCA) and its main degradation products in ointment formulations. The method, based on extensive stress testing using metal salts, azobisisobutyronitrile, acid,

  5. Development of complexation ion chromatography for the determination of metal ions

    OpenAIRE

    Bashir, Wasim

    2002-01-01

    A simple ion chromatographic method was developed for the determination of Pb(II) in river and polluted water samples. The method was based upon the use of a colourforming complexing eluent and direct visible detection of the eluting Pb(II) complex. Using the combination of a strong cation exchange column and an eluent consisting of 20 mM sodium acetate-acetic acid buffer and 0.2 mM xylenol orange (XO) (~pH = 4.2), Pb(II) was detected at 572 nm eluting in under 6.5 min. The developed method p...

  6. RESEARCH OF SOPHORA JAPONICA L. FLOWER BUDS VOLATILE COMPOUNDS WITH GAS-CHROMATOGRAPHY/MASS- SPECTROMETRY METHOD

    Directory of Open Access Journals (Sweden)

    Cholak I.S.

    2013-10-01

    Full Text Available This work represents the results of the research ofessential oil contained in Sophora japonica L. flowerbuds volatile compounds collected during the nextstages of their development: green flower buds, formedflower buds and the beginning of flower buds opening.Essential oil assay content in Sophora japonica L.flower buds was determined with hydrodistillationmethod. Content of essential oil in the raw material isless than 0,1%. Qualitative composition and assaycontent of Sophora japonica L. flower buds essential oilconstituents were determined with chromato-massspectrometry method. In consequence of the research 80constituents were identified in Sophora japonica L.flower buds out of which 61 substances are during thegreen flower buds and beginning of flower budsopening stages, 66 substances are during formed flowerbuds stage. Substances are represented by aliphatic andcyclic terpenoids, their alcohols and ketones. Mostvolatile substances were extracted on the stage offormed buds.

  7. Comparison of extraction methods for the analysis of natural dyes in historical textiles by high-performance liquid chromatography.

    Science.gov (United States)

    Valianou, Lemonia; Karapanagiotis, Ioannis; Chryssoulakis, Yannis

    2009-12-01

    Different methods for the extraction of Dactylopius coccus Costa, Rubia tinctorum L., Isatis tinctoria L., Reseda luteola L., Curcuma longa L. and Cotinus coggygria Scop. from wool fibres are investigated using high-performance liquid chromatography with diode array detector (HPLC-DAD). The efficiencies of five extraction methods which include the use of HCl (widely used extraction method), citric acid, oxalic acid, TFA and a combination of HCOOH and EDTA are compared on the basis of the (a) number, (b) relative quantities, measured as HPLC peak areas and (c) signal-to-noise ratios (S/N) of the compounds extracted from the wool substrates. Flavonoid glycosides and curcuminoids contained in R. luteola L. and C. longa L., respectively, according to liquid chromatography with mass spectrometry (LC-MS) identifications, are not detected after treating the fibres with HCl. All the other milder methods are successful in extracting these compounds. Experiments are performed using HPLC-DAD to compare the HPLC peak areas and the S/N of the following extracted compounds: indigotin, indirubin, curcumin, demethoxycurcumin, bisdemethoxycurcumin, fisetin, sulfuretin, luteolin, luteolin-7-O-glucoside, apigenin, carminic acid, alizarin, puruprin and rubiadin. It is shown that the TFA method provides overall the best results as it gives elevated extraction yields except for fisetin, luteolin, apigenin and luteolin-7-O-glucoside and highest S/N except for fisetin and luteolin-7-O-glucoside. It is noteworthy that treatment of the fibres with the typical HCl extraction method results overall in very low S/N. The TFA method is selected for further studies, as follows. First, it is applied on silk dyed samples and compared with the HCl method. The same relative differences of the TFA and HCl methods observed for the wool dyed samples are reported for the silk dyed samples too, except for rubiadin, luteolin and apigenin. Thus, in most cases, the nature of the substrate (wool or silk

  8. Analytical method by high resolution liquid chromatography for the stability study of cloratidine syrup 0.1 %

    International Nuclear Information System (INIS)

    Torres Amaro, Leonid; Garcia Penna, Caridad M; Pardo Ruiz, Zenia

    2007-01-01

    A high resolution liquid chromatography method was validated to study the stability of cloratidine syrup 0.1 %. The calibration curve in the range from 13.6 to 3.36 μg/mL was lineal, with a coefficient of correlation equal to 0.99975. The intercept and slope statistical test was not significant. The recovery obtained was 100.2 % in the concentration range studied, and the Cochran and Student (t) tests results were not important. The variation coefficient in the repeatability study was equal to 0.41 % for 10 replications assayed, whereas in the reproducibility Fischer and Student tests were not remarkable. The method proved to be specific, lineal, accurate, and exact. (Author)

  9. DEVELOPMENT OF SAMPLING AND ANALYTICAL METHODS FOR THE MEASUREMENT OF NITROUS OXIDE FROM FOSSIL FUEL COMBUSTION SOURCES

    Science.gov (United States)

    The report documents the technical approach and results achieved while developing a grab sampling method and an automated, on-line gas chromatography method suitable to characterize nitrous oxide (N2O) emissions from fossil fuel combustion sources. The two methods developed have...

  10. Determination of parabens using two microextraction methods coupled with capillary liquid chromatography-UV detection.

    Science.gov (United States)

    Chen, Chen-Wen; Hsu, Wen-Chan; Lu, Ya-Chen; Weng, Jing-Ru; Feng, Chia-Hsien

    2018-02-15

    Parabens are common preservatives and environmental hormones. As such, possible detrimental health effects could be amplified through their widespread use in foods, cosmetics, and pharmaceutical products. Thus, the determination of parabens in such products is of particular importance. This study explored vortex-assisted dispersive liquid-liquid microextraction techniques based on the solidification of a floating organic drop (VA-DLLME-SFO) and salt-assisted cloud point extraction (SA-CPE) for paraben extraction. Microanalysis was performed using a capillary liquid chromatography-ultraviolet detection system. These techniques were modified successfully to determine four parabens in 19 commercial products. The regression equations of these parabens exhibited good linearity (r 2 =0.998, 0.1-10μg/mL), good precision (RSD<5%) and accuracy (RE<5%), reduced reagent consumption and reaction times (<6min), and excellent sample versatility. VA-DLLME-SFO was also particularly convenient due to the use of a solidified extract. Thus, the VA-DLLME-SFO technique was better suited to the ex