WorldWideScience

Sample records for chromatography gas

  1. Gas Chromatography.

    Science.gov (United States)

    Karasek, Francis W.; And Others

    1984-01-01

    This review covers fundamental developments in gas chromatography during 1982 and 1983. Literature is considered under these headings: columns; liguid phases; solid supports; sorption processes and solvents; open tubular column gas chromatography; instrumentation; high-resolution columns and applications; other techniques; qualitative and…

  2. Gas chromatography

    Science.gov (United States)

    Guiochon, Georges; Guillemin, Claude L.

    1990-11-01

    Gas chromatography is a powerful separation technique for gas and vapor mixtures. Combining separation and on-line detection permits accurate quantitative analysis of complex mixtures, including traces of compounds down to parts per trillions in some particular cases. The importance of gas chromatography in quality control and process control in the chemical and drug industry, in environmental pollution investigations and in clinical analysis is critical. The principles of the technique are discussed, the main components of a gas chromatograph are described and some idea of the importance of the applications is given.

  3. Gas chromatography in space

    Science.gov (United States)

    Akapo, S. O.; Dimandja, J. M.; Kojiro, D. R.; Valentin, J. R.; Carle, G. C.

    1999-01-01

    Gas chromatography has proven to be a very useful analytical technique for in situ analysis of extraterrestrial environments as demonstrated by its successful operation on spacecraft missions to Mars and Venus. The technique is also one of the six scientific instruments aboard the Huygens probe to explore Titan's atmosphere and surface. A review of gas chromatography in previous space missions and some recent developments in the current environment of fiscal constraints and payload size limitations are presented.

  4. Multiplex gas chromatography

    Science.gov (United States)

    Valentin, Jose R.

    1990-01-01

    The principles of the multiplex gas chromatography (GC) technique, which is a possible candidate for chemical analysis of planetary atmospheres, are discussed. Particular attention is given to the chemical modulators developed by present investigators for multiplex GC, namely, the thermal-desorption, thermal-decomposition, and catalytic modulators, as well as to mechanical modulators. The basic technique of multiplex GC using chemical modulators and a mechanical modulator is demonstrated. It is shown that, with the chemical modulators, only one gas stream consisting of the carrier in combination with the components is being analyzed, resulting in a simplified instrument that requires relatively few consumables. The mechanical modulator demonstrated a direct application of multiplex GC for the analysis of gases in atmosphere of Titan at very low pressures.

  5. Gas chromatography: mass selective detector

    International Nuclear Information System (INIS)

    The mechanism of mass spectrometry technique directed for detecting molecular structures is described, with some considerations about its operational features. This mass spectrometer is used as a gas chromatography detector. (author)

  6. Thermal modulation for gas chromatography

    Science.gov (United States)

    Hasselbrink, Ernest F. (Inventor); Libardoni, Mark (Inventor); Stewart, Kristine (Inventor); Waite, J. Hunter (Inventor); Block, Bruce P. (Inventor); Sacks, Richard D. (Inventor)

    2007-01-01

    A thermal modulator device for gas chromatography and associated methods. The thermal modulator device includes a recirculating fluid cooling member, an electrically conductive capillary in direct thermal contact with the cooling member, and a power supply electrically coupled to the capillary and operable for controlled resistive heating of the capillary. The capillary can include more than one separate thermally modulated sections.

  7. Automated gas chromatography

    Science.gov (United States)

    Mowry, Curtis D.; Blair, Dianna S.; Rodacy, Philip J.; Reber, Stephen D.

    1999-01-01

    An apparatus and process for the continuous, near real-time monitoring of low-level concentrations of organic compounds in a liquid, and, more particularly, a water stream. A small liquid volume of flow from a liquid process stream containing organic compounds is diverted by an automated process to a heated vaporization capillary where the liquid volume is vaporized to a gas that flows to an automated gas chromatograph separation column to chromatographically separate the organic compounds. Organic compounds are detected and the information transmitted to a control system for use in process control. Concentrations of organic compounds less than one part per million are detected in less than one minute.

  8. Electrostatic interactions in gas-solid chromatography.

    Science.gov (United States)

    Benson, S. W.; King, J., Jr.

    1966-01-01

    Electrostatic theory of physical adsorption applied to gas-solid chromatography, discussing chromatographic inseparability of argon and oxygen at room temperature, prediction of elution order of many gases, etc

  9. Flow Rates in Liquid Chromatography, Gas Chromatography and Supercritical Fluid Chromatography: A Tool for Optimization

    OpenAIRE

    Meurs, Joris

    2016-01-01

    This paper aimed to develop a standalone application for optimizing flow rates in liquid chromatography (LC), gas chromatography (GC) and supercritical fluid chromatography (SFC). To do so, Van Deemter’s equation, Knox’ equation and Golay’s equation were implemented in a MATLAB script and subsequently a graphical user interface (GUI) was created. The application will show the optimal flow rate or linear velocity and the corresponding plate height for the set input parameters. Furthermore, a p...

  10. HD gas analysis with Gas Chromatography and Quadrupole Mass Spectrometer

    CERN Document Server

    Ohta, T; Didelez, J -P; Fujiwara, M; Fukuda, K; Kohri, H; Kunimatsu, T; Morisaki, C; Ono, S; Rouille, G; Tanaka, M; Ueda, K; Uraki, M; Utsuro, M; Wang, S Y; Yosoi, M

    2011-01-01

    A gas analyzer system has been developed to analyze Hydrogen-Deuteride (HD) gas for producing frozen-spin polarized HD targets, which are used for hadron photoproduction experiments at SPring-8. Small amounts of ortho-H$_{2}$ and para-D$_{2}$ gas mixtures ($\\sim$0.01%) in the purified HD gas are a key to realize a frozen-spin polarized target. In order to obtain reliable concentrations of these gas mixtures in the HD gas, we produced a new gas analyzer system combining two independent measurements with the gas chromatography and the QMS. The para-H$_{2}$, ortho-H$_{2}$, HD, and D$_{2}$ are separated using the retention time of the gas chromatography and the mass/charge. It is found that the new gas analyzer system can measure small concentrations of $\\sim$0.01% for the otho-H$_2$ and D$_2$ with good S/N ratios.

  11. Soil moisture by extraction and gas chromatography

    Science.gov (United States)

    Merek, E. L.; Carle, G. C.

    1973-01-01

    To determine moisture content of soils rapidly and conveniently extract moisture with methanol and determine water content of methanol extract by gas chromatography. Moisture content of sample is calculated from weight of water and methanol in aliquot and weight of methanol added to sample.

  12. Non-planar microfabricated gas chromatography column

    Science.gov (United States)

    Lewis, Patrick R.; Wheeler, David R.

    2007-09-25

    A non-planar microfabricated gas chromatography column comprises a planar substrate having a plurality of through holes, a top lid and a bottom lid bonded to opposite surfaces of the planar substrate, and inlet and outlet ports for injection of a sample gas and elution of separated analytes. A plurality of such planar substrates can be aligned and stacked to provide a longer column length having a small footprint. Furthermore, two or more separate channels can enable multi-channel or multi-dimensional gas chromatography. The through holes preferably have a circular cross section and can be coated with a stationary phase material or packed with a porous packing material. Importantly, uniform stationary phase coatings can be obtained and band broadening can be minimized with the circular channels. A heating or cooling element can be disposed on at least one of the lids to enable temperature programming of the column.

  13. Improved Thermal Modulator for Gas Chromatography

    Science.gov (United States)

    Hasselbrink, Ernest Frederick, Jr.; Hunt, Patrick J.; Sacks, Richard D.

    2008-01-01

    An improved thermal modulator has been invented for use in a variant of gas chromatography (GC). The variant in question denoted as two-dimensional gas chromatography (2DGC) or GC-GC involves the use of three series-connected chromatographic columns, in the form of capillary tubes coated interiorly with suitable stationary phases (compounds for which different analytes exhibit different degrees of affinity). The two end columns are relatively long and are used as standard GC columns. The thermal modulator includes the middle column, which is relatively short and is not used as a standard GC column: instead, its temperature is modulated to affect timed adsorption and desorption of analyte gases between the two end columns in accordance with a 2DGC protocol.

  14. Measurement of HD concentration by gas chromatography

    International Nuclear Information System (INIS)

    Gas chromatography has been used for the on-line measurement of deuterium hydride (HD) which is used in a Tritium Removal Pilot Facility for the demonstration of the removal of the tritium mainly generated in CANDU reactors. Two methods with different carrier gases, neon and hydrogen, are tested and compared each other. It was showed that both the methods could be possible to measure the concentration of H2 and HD. However, the method with a column packed with alumina showed difficulty in the application due to quite long measurement time and reproducibility. The other method using hydrogen as a carrier gas could measure the concentration accurately within comparably short period

  15. Normalization of natural gas composition data measured by gas chromatography

    International Nuclear Information System (INIS)

    The composition of natural gas determined by gas chromatography is routinely used as the basis for calculating physico-chemical properties of the gas. Since the data measured by gas chromatography have particular statistical properties, the methods used to determine the composition can make use of a priori assumptions about the statistical model for the data. We discuss a generalized approach to determining the composition, and show that there are particular statistical models for the data for which the generalized approach reduces to the widely used method of post-normalization. We also show that the post-normalization approach provides reasonable estimates of the composition for cases where it cannot be shown to arise rigorously from the statistical structure of the data

  16. Gas chromatography of alkylphosphonic and dialkylphosphinic acids

    International Nuclear Information System (INIS)

    After carrying out an optimization study on the separation conditions for the TMS-derivatives, of the hexyl-, cyclohexyl-, heptyl-, and octyl-phosphonic acids; dihexyl-, dicyclohexyl-, heptyl-, and octyl-phosphinic acids, and dioctylphosphine oxide, their retention indices (I) at two temperatures and on the 0V-1 and 0V-17 stationary phase were determined. Correlations between I and molecular structure were established. Calibration factors of these compounds in the flame ionization detector were studied, and the results analized taking into account the variables afecting the quantitative results. These results were unbiased but they had a lower precission than usually achieveble in gas chromatography. (author)

  17. Clinical applications of gas chromatography and gas chromatography-mass spectrometry of steroids

    NARCIS (Netherlands)

    Wolthers, BG; Kraan, GPB

    1999-01-01

    This review article underlines the importance of gas chromatography-mass spectrometry (GC-MS) for determination of steroids in man. The use of steroids labelled with stable isotopes as internal standard and subsequent analysis by GC-MS yields up to now the only reliable measurement of steroids in se

  18. Modeling of gas sample behavior in gas chromatography column

    OpenAIRE

    Gniazdowski, Zenon; Kowalski, Pawel

    2016-01-01

    The equilibrium-dispersive model of the linear GC (gas chromatography) was derived using both assumptions and the method of its derivation different from the known in literature. It was concluded that this model is a specific case of the Fokker-Planck equation for diffusion with drift. The resolution of this derived equation for assumed initial conditions is the normal distribution with movable mean value. At the end of the GC column the standard deviation of this distribution was investigate...

  19. Simulating retention in gas-liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Martin, M.G.; Siepmann, J.I.; Schure, M.R.

    1999-12-16

    Accurate predictions of retention times, retention indices, and partition constants are a long sought-after goal for theoretical studies in chromatography. Configurational-bias Monte Carlo (CBMC) simulations in the Gibbs ensemble using the transferable potentials for phase equilibria-united atom (TraPPE-UA) force field have been carried out to obtain a microscopic picture of the partitioning of 10 alkane isomers between a helium vapor phase and a squalane liquid phase, a protypical gas-liquid chromatography system. The alkane solutes include some topological isomers that differ only in the arrangement of their building blocks (e.g., 2,5-dimethylhexane and 3,4-dimethylhexane), for which the prediction of the retention order is particularly difficult. The Kovats retention indices, a measure of the relative retention times, are calculated directly from the partition constants and are in good agreement with experimental values. The calculated Gibbs free energies of transfer for the normal alkanes conform to Martin's equation which is the basis of linear free energy relationships used in many process modeling packages. Analysis of radial distribution functions and the corresponding energy integrals does not yield evidence for specific retention structures and shows that the internal energy of solvation is not the main driving force for the separation of topological isomers in this system.

  20. Freeze drying for gas chromatography stationary phase deposition

    Science.gov (United States)

    Sylwester, Alan P.

    2007-01-02

    The present disclosure relates to methods for deposition of gas chromatography (GC) stationary phases into chromatography columns, for example gas chromatography columns. A chromatographic medium is dissolved or suspended in a solvent to form a composition. The composition may be inserted into a chromatographic column. Alternatively, portions of the chromatographic column may be exposed or filled with the composition. The composition is permitted to solidify, and at least a portion of the solvent is removed by vacuum sublimation.

  1. Forensic potential of comprehensive two-dimensional gas chromatography

    NARCIS (Netherlands)

    A. Sampat; M. Lopatka; M. Sjerps; G. Vivo-Truyols; P. Schoenmakers; A. van Asten

    2016-01-01

    In this study, the application of comprehensive two-dimensional (2D) gas chromatography (GC × GC) in forensic science is reviewed. The peer-reviewed publications on the forensic use of GC × GC and 2D gas chromatography with mass spectrometric detection (GC × GC-MS) have been studied in detail, not o

  2. Hydrogen isotopes separation by gas phase chromatography

    International Nuclear Information System (INIS)

    Gas chromatography on a Pd or PdAl2O3 column is commonly used for separation of hydrogen isotopes. This report presents recent related studies conducted in the Department of Chemistry at the Bruyeres-le-Chatel Research Center. They represent a first step in an optimization study of separation process. A simple thermodynamic model based on concentration-dependent separation factors and concentration front velocities is discussed. It allows the prediction of the separation evolution of ternary (H2, D2, T2) mixtures on an initially saturated Pd-Al2O3 column. Pressure-composition-temperature curves for Pd-Al2O3 (H2, D2, T2) systems were measured at temperatures ranging from 295 K to 353 K in order to get data for model validation. Next we performed chromatographic experiments with pure gases and binary (H2, D2) mixtures for different operating conditions (flow rate, temperature, isotope). Calculated values are consistent with experimental results. Finally we present a few applications showing the interest of our model for recovery of T2-rich gas

  3. Mixed Stationary Liquid Phases for Gas-Liquid Chromatography.

    Science.gov (United States)

    Koury, Albert M.; Parcher, Jon F.

    1979-01-01

    Describes a laboratory technique for use in an undergraduate instrumental analysis course that, using the interpretation of window diagrams, prepares a mixed liquid phase column for gas-liquid chromatography. A detailed procedure is provided. (BT)

  4. Automotive gasoline quality analysis by gas chromatography: study of adulteration

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, L.S.; Azevedo, D.A. [Dept. de Quimica Organica, Univ. Federal do Rio de Janeiro, Ilha do Fundao, Rio de Janeiro, RJ (Brazil); d' Avila, L.A. [Dept. de Processos Organicos, Univ. Federal do Rio de Janeiro, Ilha do Fundao, Rio de Janeiro, RJ (Brazil)

    2003-10-01

    The addition of organic solvents (light aliphatic, heavy aliphatic and aromatic hydrocarbons) in Brazilian gasoline is unfortunately very frequent, and this illicit practice impares gasoline quality. Gas chromatography (GC) and gas chromatography coupled to mass spectrometry (GC-MS) analyses can be used as a procedure to improve the detection of adulterated gasoline. The results showed that adulterated samples and also the type of organic solvent used in adulteration can be detected by comparison of chromatographic profiles (standard samples versus adulterated samples). However, a single GC analysis can detect an adulterated gasoline, and so decrease the number of adulterated samples approved as presenting good quality. (orig.)

  5. Theoretical Studies of PCl3/H2 Gas Chromatography Mechanism

    Institute of Scientific and Technical Information of China (English)

    WANG Yan-Li; MA Lin; SUN Ren-An

    2007-01-01

    Density functional theory B3LYP method was firstly applied to fully optimize the geometrical configuration of each stable point on PCl3/H2 gas chromatography reaction potential energy surface on the 6-311G** basis set, and single point energy was computed at the QCISD(T)/ 6-311G** level, then the transition state was validated by analyzing the unique imaginary vibration modes of each transition state and calculating intrinsic reaction coordinate (IRC), and the major reaction and competing reaction paths of PCl3/H2 gas chromatography reaction were presented through comparing active energy barrier, and phosphor was finally gained from the reaction of PH and PCl.

  6. Surface characterization of ashtree wood meal by inverse gas chromatography

    Institute of Scientific and Technical Information of China (English)

    ZHAO Shu; LIN Xu; SONG JingWei; SHI BaoLi

    2007-01-01

    Inverse gas chromatography (IGC) is a sensitive and convenient method to characterize surface properties and thermodynamic parameters of solid materials. Surface properties of ashtree wood meal were determined by inverse gas chromatography in this work. The dispersive component of the surface free energy and acid-base parameters of the ashtree wood meal were characterized. The dispersive component of surface free energy was within 36-39 mJ/m2, the Lewis acidic number Ka was 0.53, and the basic number Kb was 0.21, respectively. The results show that ashtree is amphoteric and predominantly acidic wood.

  7. Development of a thermal desorption modulator for gas chromatography

    NARCIS (Netherlands)

    Geus, H.J.; Boer, de J.; Brinkman, U.A.Th.

    1997-01-01

    The separation space in gas chromatography can be enhanced dramatically by the comprehensive coupling of two independent separation dimensions. An interface between the two columns must accumulate analytes eluting from the first dimension, focus them and at the appropriate moment transfer them to th

  8. An application of gas chromatography to planetary atmospheres

    Science.gov (United States)

    Oyama, V.

    1974-01-01

    A gas chromatography developed for the Viking experiment is described. The instrument is designed to measure gases in planetary atmospheres and head space in a chamber. It is hoped that the chromatograph will also measure any biological activity present in these environments.

  9. Gas chromatography mass spectrometry : key technology in metabolomics

    NARCIS (Netherlands)

    Koek, Maud Marijtje

    2009-01-01

    Metabolomics involves the unbiased quantitative and qualitative analysis of the complete set of metabolites present in cells, body fluids and tissues. Gas chromatography coupled to mass spectrometry (GC-MS) is very suitable for metabolomics analysis, as it combines high separation power with sensiti

  10. Enthalpy of Vaporization by Gas Chromatography: A Physical Chemistry Experiment

    Science.gov (United States)

    Ellison, Herbert R.

    2005-01-01

    An experiment is conducted to measure the enthalpy of vaporization of volatile compounds like methylene chloride, carbon tetrachloride, and others by using gas chromatography. This physical property was measured using a very tiny quantity of sample revealing that it is possible to measure the enthalpies of two or more compounds at the same time.

  11. Analysis of essential oils by gas chromatography and mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Masada, Y.

    1976-01-01

    The book is in two parts: first part Essential Oil includes compositae; labiatae; verbenaceae; oleaceae; umbelliferae; myrtaceae; euphorbiaceae; rutaceae; geraniaceae; rosaceae; lauraceae; myristicaceae; anonaceae; santalaceae; moraceae; piperaceae; zingiberaceae; araceae; gramineae; and cupressaceae written in English and Japanese. Part two includes essential oil; gas chromatography, and mass spectrometry written in Japanese. (DP)

  12. Specialized Gas Chromatography--Mass Spectrometry Systems for Clinical Chemistry.

    Science.gov (United States)

    Gochman, Nathan; And Others

    1979-01-01

    A discussion of the basic design and characteristics of gas chromatography-mass spectrometry systems used in clinical chemistry. A comparison of three specific systems: the Vitek Olfax IIA, Hewlett-Packard HP5992, and Du Pont DP-102 are included. (BB)

  13. Adsorption gas chromatography with 150-ms 216Po

    International Nuclear Information System (INIS)

    A gas chromatography apparatus was developed, which allows experiments with volatile radionuclides having shorter half-lives than one second. This apparatus was tested with the 150-ms isotope 216Po. Experimental data were compared with a Monte Carlo model to determine the adsorption enthalpy ΔHa. (author) 2 figs., 2 refs

  14. Using Single Drop Microextraction for Headspace Analysis with Gas Chromatography

    Science.gov (United States)

    Riccio, Daniel; Wood, Derrick C.; Miller, James M.

    2008-01-01

    Headspace (HS) gas chromatography (GC) is commonly used to analyze samples that contain non-volatiles. In 1996, a new sampling technique called single drop microextraction, SDME, was introduced, and in 2001 it was applied to HS analysis. It is a simple technique that uses equipment normally found in the undergraduate laboratory, making it ideal…

  15. Multiplex gas chromatography for use in space craft

    Science.gov (United States)

    Valentin, J. R.

    1985-01-01

    Gas chromatography is a powerful technique for the analysis of gaseous mixtures. Some limitations in this technique still exist which can be alleviated with multiplex gas chromatography (MGC). In MGC, rapid multiple sample injections are made into the column without having to wait for one determination to be finished before taking a new sample. The resulting data must then be reduced using computational methods such as cross correlation. In order to efficiently perform multiplexgas chromatography, experiments in the laboratory and on board future space craft, skills, equipment, and computer software were developed. Three new techniques for modulating, i.e., changing, sample concentrations were demonstrated by using desorption, decomposition, and catalytic modulators. In all of them, the need for a separate gas stream as the carrier was avoided by placing the modulator at the head of the column to directly modulate a sample stream. Finally, the analysis of an environmental sample by multiplex chromatography was accomplished by employing silver oxide to catalytically modulate methane in ambient air.

  16. Multiple-injection high-throughput gas chromatography analysis.

    Science.gov (United States)

    Schafer, Wes; Wang, Heather; Welch, Christopher J

    2016-08-01

    Multiple-injection techniques have been shown to be a simple way to perform high-throughput analysis where the entire experiment resides in a single chromatogram, simplifying the data analysis and interpretation. In this study, multiple-injection techniques are applied to gas chromatography with flame ionization detection and mass detection to significantly increase sample throughput. The unique issues of implementing a traditional "Fast" injection mode of multiple-injection techniques with gas chromatography and mass spectrometry are discussed. Stacked injections are also discussed as means to increase the throughput of longer methods where mass detection is unable to distinguish between analytes of the same mass and longer retentions are required to resolve components of interest. Multiple-injection techniques are shown to increase instrument throughput by up to 70% and to simplify data analysis, allowing hits in multiple parallel experiments to be identified easily. PMID:27292909

  17. Chemical Micro Preconcentrators Development for Micro Gas Chromatography Systems

    OpenAIRE

    Alfeeli, Bassam

    2010-01-01

    Microelectromechanical systems (MEMS) technology allows the realization of mechanical parts, sensors, actuators and electronics on silicon substrate. An attractive utilization of MEMS is to develop micro instruments for chemical analysis. An example is gas chromatography (GC) which is widely used in food, environmental, pharmaceutical, petroleum/refining, forensic/security, and flavors and fragrances industries. A MEMS-based micro GC (µGC) provides capabilities for quantitative analysis of c...

  18. Application of gas chromatography to the investigations on polypropylene radiolysis

    International Nuclear Information System (INIS)

    Refinement of the gas chromatography (GC) instrumental approach permitted not only improvement of investigation in basic research, but also development of a new kind of polypropylene blends, more suitable for the production of medical devices and radiation sterilization. It has been shown, that using the GC method not only methane and carbon dioxide can be measured, but also the consumption of oxygen which reacts with free radicals on the polypropylene chain

  19. Chelate-modified polymers for atmospheric gas chromatography

    Science.gov (United States)

    Christensen, W. W.; Mayer, L. A.; Woeller, F. H. (Inventor)

    1980-01-01

    Chromatographic materials were developed to serve as the stationary phase of columns used in the separation of atmospheric gases. These materials consist of a crosslinked porous polymer matrix, e.g., a divinylbenzene polymer, into which has been embedded an inorganic complexed ion such as N,N'-ethylene-bis-(acetylacetoniminato)-cobalt (2). Organic nitrogenous bases, such as pyridine, may be incorporated into the chelate polymer complexes to increase their chromatographic utility. With such materials, the process of gas chromatography is greatly simplified, especially in terms of time and quantity of material needed for a gas separation.

  20. The Use of Gas Chromatography for Biogas Analysis

    Science.gov (United States)

    Andersen, Amanda; Seeley, John; Aurandt, Jennifer

    2010-04-01

    Energy from natural gas accounts for 24 percent of energy consumed in the US. Natural gas is a robust form of energy which is rich in methane content and is low in impurities. This quality suggests that it is a very clean and safe gas; it can be used in providing heat, a source for cooking, and in powering vehicles. The downside is that it is a non-renewable resource. On the contrary, methane rich gas that is produced by the breakdown of organic material in an anaerobic environment, called biogas, is a renewable energy source. This research focuses on the gas analysis portion of the creation of the anaerobic digestion and verification laboratory where content and forensic analysis of biogas is performed. Gas Chromatography is implemented as the optimal analytical tool for quantifying the components of the biogas including methane, carbon dioxide, hydrogen sulfide and siloxanes. In addition, the problems associated with the undesirable components are discussed. Anaerobic digestion of primary sludge has consistently produced about 55 percent methane; future goals of this research include studying different substrates to increase the methane yield and decrease levels of impurities in the gas.

  1. Characterization of crude oils by inverse gas chromatography.

    Science.gov (United States)

    Mutelet, F; Ekulu, G; Rogalski, M

    2002-09-01

    It was shown that the flocculation onset of asphaltenes in crude oils could be predicted on the basis of the inverse gas chromatography characterization of the crude oil properties. Hildebrand's solubility parameters of four crude oils were calculated from inverse chromatography data and compared with values obtained from the onset of asphaltene flocculation measurements. A good agreement was observed with three crude oils of different origin. A relation between Hildebrand's solubility parameter and linear solvation energy relationship descriptors was established and it was demonstrated that the solubility parameter of a crude oil is determined mainly with dispersion interactions and the hydrogen bond basicity. A large basicity lowers the oil solubility parameter, and increases its stability in respect to flocculation. PMID:12385392

  2. A novel ionic liquids grafted polysiloxane for capillary gas chromatography

    Institute of Scientific and Technical Information of China (English)

    Qing Quan Wei; Mei Ling Qi; Ruo Nong Fu

    2009-01-01

    A new ionic liquids grafted polysiloxane used as stationary phase for capillary gas chromatography(CGC)is described.The stationary phase of 1-vinyl-3-hexylimidazolium hexafluorophosphate anchored to polysiloxane(PMHS-[VHIm][PF6])was synthesized,characterized and coated onto capillary columns by static coating.The results show that the present stationary phase exhibits a very good chromatographic resolution and selectivity for Grob test mixture and alcohols with baseline resolution and symmetry peaks.The present work suggests that novel stationary phase has a great potential for further development and application.

  3. Continuous monitoring of a changing sample by multiplex gas chromatography

    Science.gov (United States)

    Valentin, Jose R.; Hall, Kirsten W.; Becker, Joseph F.

    1990-01-01

    Results are presented from a study in which a continuously changed gaseous sample was monitored by multiplex gas chromatography (MGC), using the exponential dilution (ED) technique of Ritter and Adams (1976) to change the composition and concentration of a gaseous mixture in such a way as to imitate changes in the atmospheric gases sampled by a descending aircraft. A calibration of the MGC system was performed with four different rates of sample dilution, and the errors resulting from various degrees of change in the sample concentration were determined.

  4. Gas-liquid chromatography in lunar organic analysis.

    Science.gov (United States)

    Gehrke, C. W.

    1972-01-01

    Gas-liquid chromatography (GLC) is a powerful and sensitive method for the separation and detection of organic compounds at nanogram levels. The primary requirement for successful analyses is that the compounds of interest must be volatile under the chromatographic conditions employed. Nonvolatile organic compounds must be converted to volatile derivatives prior to analysis. The derivatives of choice must be both amenable to chromatographic separation and be relatively stable. The condition of volatility necessitates the development of efficient derivatization reactions for important groups of compounds as amino acids, carbohydrates, nucleosides, etc. Trimethylsilylation and trifluoroacetylation represent specific areas of recent prominence. Some relevant practical aspects of GLC are discussed.

  5. Micro analysis of disolved gases by the gas chromatography technique

    International Nuclear Information System (INIS)

    A technique which allows the quantitative analysis of small concentration of disolved gases such as CO2 and H2 in the order of 10-6 - 10-3M is discussed. For the extraction, separation and quantification a Toepler pump was used. This is in tandem to a gas chromatography. This method also can be applied for the analysis of other gases like CO, CH4, CH3-CH3 etc. This technique may be applied in fields such as radiation chemistry, oceanography and environmental studies. (author)

  6. Diesel characterization by high-resolution mass spectrometry - gas chromatography

    International Nuclear Information System (INIS)

    High-resolution mass spectrometry-gas chromatography is combined with the HC22 method in order to obtain detailed information about the chemical composition of diesel and the distribution of different compound types in terms of its final boiling temperature from a single analysis. The total time elapsed from sample injection and signal processing to obtain final results is 90 minutes. This fact makes this methodology a new and very important tool for the decision making process concerning the most suitable final boiling temperature and the type of treatment of the product in order to obtain diesel that fulfills the international standards. The consistency and repeatability of the experimental results are demonstrated

  7. Gas chromatography of alkylphosphonic and dialkyl phosphinic acids

    International Nuclear Information System (INIS)

    After carrying out an optimization study on the separation conditions for the TMSr- derivatives, of the hexyl-, cyclohexyl-, heptyl-, and octyl-phosphonic acids; dihexyl dicyclohexyl-, heptyl-, and octyl-phosphinic acids, and dioctyl phosphine oxide, their retention indices (I) at two temperatures and on the OV-1 and OV-17 stationary phase were determined. Correlations between I and molecular structure were established. Calibration factors of these compounds in the flame ionization detector were studied, and the results analyzed taking into account the variables affecting the quantitative results, These results were unbiased but they had a lower precision than that usually achievable in gas chromatography. (Author) 24 refs

  8. [Determination of acetochlor and oxyfluorfen by capillary gas chromatography].

    Science.gov (United States)

    Xiang, Wen-Sheng; Wang, Xiang-Jing; Wang, Jing; Wang, Qing

    2002-09-01

    A method is described for the determination of acetochlor and oxyfluorfen by capillary gas chromatography with FID and an SE-30 capillary column (60 m x 0.53 mm i. d., 1.5 microm), using dibutyl phthalate as the internal standard. The standard deviations for acetochlor and oxyfluorfen concentration(mass fraction) were 0.44% and 0.47% respectively. The relative standard deviations for acetochlor and oxyfluorfen were 0.79% and 0.88% and the average recoveries for acetochlor and oxyfluorfen were 99.3% and 101.1% respectively. The method is simple, rapid and accurate. PMID:16358708

  9. Thermal History Of PMRs Via Pyrolysis-Gas Chromatography

    Science.gov (United States)

    Gluyas, Richard E.; Alston, William B.; Snyder, William J.

    1994-01-01

    Pyrolysis-gas chromatography (PY-GC) useful as analytical technique to determine extents of cure or postcure of PMR-15 polyimides and to lesser extent, cumulative thermal histories of PMR-15 polyimides exposed to high temperatures. Also applicable for same purposes to other PMR polyimides and to composite materials containing PMR polyimides. Valuable in reducing costs and promoting safety in aircraft industry by helping to identify improperly cured or postcured PMR-15 composite engine and airframe components and helping to identify composite parts nearing ends of their useful lives.

  10. Chromatography.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  11. 21 CFR 862.2250 - Gas liquid chromatography system for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid...

  12. High performance mini-gas chromatography-flame ionization detector system based on micro gas chromatography column

    Science.gov (United States)

    Zhu, Xiaofeng; Sun, Jianhai; Ning, Zhanwu; Zhang, Yanni; Liu, Jinhua

    2016-04-01

    Monitoring Volatile organic compounds (VOCs) was a very important measure for preventing environmental pollution, therefore, a mini gas chromatography (GC) flame ionization detector (FID) system integrated with a mini H2 generator and a micro GC column was developed for environmental VOC monitoring. In addition, the mini H2 generator was able to make the system explode from far away due to the abandoned use of a high pressure H2 source. The experimental result indicates that the fabricated mini GC FID system demonstrated high repeatability and very good linear response, and was able to rapidly monitor complicated environmental VOC samples.

  13. Novel stationary phases based on asphaltenes for gas chromatography.

    Science.gov (United States)

    Boczkaj, Grzegorz; Momotko, Malwina; Chruszczyk, Dorota; Przyjazny, Andrzej; Kamiński, Marian

    2016-07-01

    We present the results of investigations on the possibility of the application of the asphaltene fraction isolated from the oxidized residue from vacuum distillation of crude oil as a stationary phase for gas chromatography. The results of the investigation revealed that the asphaltene stationary phases can find use for the separation of a wide range of volatile organic compounds. The experimental values of Rohrschneider/McReynolds constants characterize the asphaltenes as stationary phases of medium polarity and selectivity similar to commercially available phases based on alkyl phthalates. Isolation of asphaltenes from the material obtained under controlled process conditions allows the production of a stationary phase having reproducible sorption properties and chromatographic columns having the same selectivity. Unique selectivity and high thermal stability make asphaltenes attractive as a material for stationary phases for gas chromatography. A low production cost from a readily available raw material (oxidized petroleum bitumens) is an important economic factor in case of application of the asphaltene stationary phases for preparative and process separations. PMID:27144876

  14. Characterization of the fermentation process by gas chromatography Lasiodiplodia theobromae and gas chromatography coupled with mass spectrometry

    International Nuclear Information System (INIS)

    Lasiodiplodia theobromae is a fungus, which has been reported by some authors as a high yield producer of the phytohormone jasmonic acid (JA). An indigenous strain of this fungus has been used for producing a fermentation broth with a high JA concentration by the Cuban Research Institute for Sugar Cane Derivatives (ICIDCA), registered as BIOJAS. The broth has been applied to some agricultural crops and demonstrated its economic feasibility as plant growth regulator and biological control of various phytopathogenic microorganisms and pests. Both fermentation broth and biomass from this fungus contain some other metabolites having bioactive properties, for instance, fatty acids. This paper shows the composition and quantification of fatty acids in the biomass using Gas Chromatography (GC) and the identification of substances profile in fermentation broth by Gas Chromatography coupled to Mass Spectrometry (GC-MS). The most fatty acids in the biomass are palmitic, stearic, oleic, linoleic and linolenic acids, being oleic acid the major component. On the other hand, 2,32 % of fatty acid esters; 2,47 % of alkenes; 14,40 % of alcohols; 30,15 % of aldehydes and 21,73 % of paraffins were detected in the composition of fermentation broth

  15. Low thermal mass gas chromatography: principles and applications.

    Science.gov (United States)

    Luong, Jim; Gras, Ronda; Mustacich, Robert; Cortes, Hernan

    2006-01-01

    In gas chromatography (GC), temperature programming is often considered to be the second most important parameter to control, the first being column selectivity. A radically new GC technology to achieve ultrafast temperature programming with an unprecedented cool down time and low power consumption has recently become available. This technology is referred to as low thermal mass GC (LTMGC). Though the technology has its roots in resistive heating, which forms the basis of principle and design concept, the approach taken to achieve ultrafast heating and cool down time by LTMGC represents a significant break-through in GC. Despite some rectifiable shortcomings, LTMGC has proven to be an ideal methodology to deliver near/real time GC data, high precision, and high throughput applications. It is a new approach for modern high-speed GC. This paper documents the fundamental design principles behind LTMGC, performance data, and examples of applications investigated. PMID:16774710

  16. Surface Characterization of Glass Fiber by Inverse Gas Chromatography

    Institute of Scientific and Technical Information of China (English)

    HUANG Xiaohua; LI Bin; SHI Baoli; GUO Xuefei; JIA Lina

    2008-01-01

    The surface properties of glass fiber were quantificationally analyzed by inverse gas chromatography (IGC). Five n-alkanes (C6, C7, C8, C9, and C10) were chosen as apolar probes to characterize the dispersive component of surface free energy. Trichloromethane (CHCl3), acetone,and tetrahydrofuran (THF) were chosen as polar probes to detect the Lewis acid-base parameters. It is found that the dispersive components of free energy are 32.3, 30.5, 27.5, and 26.9 Mj/m2 at 70,80, 90, and 100 ℃, respectively. The Lewis acidic number Ka of the glass fiber is 0.512 4, and the basic number Kb is 2.862. The results mean the glass fiber is a Lewis basic material.

  17. Selective data reduction in gas chromatography/infrared spectrometry

    International Nuclear Information System (INIS)

    As gas chromatography/infrared spectrometry (GC/IR) becomes routinely available, methods must be developed to deal with the large amount of data produced. We demonstrate computer methods that quickly search through a large data file, locating those spectra that display a spectral feature of interest. Based on a modified library search routine, these selective data reduction methods retrieve all or nearly all of the compounds of interest, while rejection the vast majority of unrelated compounds. To overcome the shifting problem of IR spectra, a search method of moving the average pattern was designed. In this moving pattern search, the average pattern of a particular functional group was not held stationary, but was allowed to be moved a little bit right and left

  18. Identification of Cyclopentenyl Fatty Acids by Gas Liquid Chromatography and Mass Spectrometry

    DEFF Research Database (Denmark)

    Shukla, V. K. S.; Abdel-Moety, E. M.; Larsen, Elfinn;

    1979-01-01

    The straight chain fatty acids and the cyclopentenyl fatty acids present in the lipids of Hydnocarpus wightiana seeds were separated as their pyrrolidides by means of gas chromatography. A gas chromatography-mass spectrometry system confirmed the complete separation and permitted the identification...

  19. Biomedical applications of gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Gas chromatography coupled with mass-spectrometry (GC/MS) is a modern technique, which has very important applications in the biomedical area. A large number of qualitative and quantitative determinations of drugs, amino acids, vitamins, lipids, aroma compounds, important nutrients, herb extracts were developed. The extraction procedure is the first important step in the analytical work. The internal standard is usually added at the very begin ing of the quantitative work. The best one is the stable isotopic labeled compound, usually the analogue of the compound of interest. Stable isotopic internal standard or compounds from the same chemical class having boiling point close to that of the compound of interest were used. Quantitation needs very well selected standards and method validation. Some validated methods for the determination of drugs and some active principles in biological media are presented. Several preconcentration extraction procedures were used. The quantitative determinations by detection (GC-MS) were performed. Good validation parameters were obtained: precision, accuracy, linearity in the range of interest, good limit of detection and quantitation, selectivity and specificity. Chromatography was performed on a 5% phenyl methyl polysiloxane column (15 or 30 m x 0.25 mm I.D., 0.25 μm film thickness) operated in suitable temperature programs. Helium carrier gas flow was 1ml/min. Ionization was performed by electron impact and detection in scan or selected ion monitoring (SIM) modes. The methods provided high response linearity (mean r = 0.99), precision and accuracy (< 10% C.V.). Applications of the quantitative methods in biomedical area are described. (author)

  20. Chemical Discrimination in Turbulent Gas Mixtures with MOX Sensors Validated by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Jordi Fonollosa

    2014-10-01

    Full Text Available Chemical detection systems based on chemo-resistive sensors usually include a gas chamber to control the sample air flow and to minimize turbulence. However, such a kind of experimental setup does not reproduce the gas concentration fluctuations observed in natural environments and destroys the spatio-temporal information contained in gas plumes. Aiming at reproducing more realistic environments, we utilize a wind tunnel with two independent gas sources that get naturally mixed along a turbulent flow. For the first time, chemo-resistive gas sensors are exposed to dynamic gas mixtures generated with several concentration levels at the sources. Moreover, the ground truth of gas concentrations at the sensor location was estimated by means of gas chromatography-mass spectrometry. We used a support vector machine as a tool to show that chemo-resistive transduction can be utilized to reliably identify chemical components in dynamic turbulent mixtures, as long as sufficient gas concentration coverage is used. We show that in open sampling systems, training the classifiers only on high concentrations of gases produces less effective classification and that it is important to calibrate the classification method with data at low gas concentrations to achieve optimal performance.

  1. Analysis of odour compounds from scented consumer products using gas chromatography-mass spectrometry and gas chromatography-olfactometry.

    Science.gov (United States)

    Bartsch, Jennifer; Uhde, Erik; Salthammer, Tunga

    2016-01-21

    Scented consumer products are being bought in increasing amounts and gaining more popularity. There is, however, relatively little information available about their ingredients, emissions and allergenic potential. Frequently, a mixture of different fragrance substances and not solely an individual substance contributes to the overall desired smell. The aim of this study was to investigate the odorous volatile organic compounds (OVOCs) in consumer products containing fragrances. Over 44 products were selected: various scented candles, printing products with different scent types and other products types particularly meant to be used indoors. Measurements were carried out in a desiccator. Air samples were collected on thermal desorption tubes to determine the released fragrance substances by means of gas chromatography-mass spectrometry (GC-MS). Moreover, gas chromatography-olfactometry (GC-O) was used to obtain sensory data and to ensure no important odorant was overlooked. Using both methods it was possible to distinguish between odour active and inactive compounds and subsequently to identify almost 300 different odorants across all scented products. Besides the advantage of differentiation, as the human nose is a very sensitive detector, GC-O was found to be a useful tool for detecting traces and chosen target compounds. One focus in this study lay on the 26 EU-regulated fragrance allergens to prove their relevance in scented consumer goods. In total, 18 of them were identified, with at least one substance being present in almost every product. Benzyl alcohol, cinnamaldehyde, citronellol, eugenol, linalool and limonene were the prevalently detected allergens. Particularly linalool and limonene were observed in over 50% of the products. In addition, eugenol appeared to be one of the most frequently detected compounds in trace-level concentrations in the candle emissions.

  2. Plasma emission spectral detection for pyrolysis-gas chromatography

    Science.gov (United States)

    Riska, Gregory D.; Estes, Scott A.; Beyer, John O.; Uden, Peter C.

    Specific element gas chromatographic detection by plasma emission spectroscopy has been evaluated for the characterization of volatile pyrolyzates from a number of polymers containing hetero-atoms. Directly interfaced rapid-temperature rise time pyrolysis with high resolution open tubular column gas chromatography was employed. The atmospheric pressure microwave induced and sustained plasma utilizing a "Beenakker" type TM 010 cavity was applied for specific detection of phosphorus and carbon in polyphosphazene pyrolysis and for boron in carborane-silicone pyrolysis. An interfaced d.c. argon atmospheric pressure plasma was found more advantageous for the specific determination of silicon in the pyrolysis products of novel linear silarylene-siloxanes. In phosphazene pyrolysis notable differences were seen in the phosphorus content of volatiles formed on pyrolysis between polymers fluoroalkoxy and chlorophenoxy substituents. For carborane-silicones sequential volatilization followed by pyrolysis allowed the identification of residual boron containing monomers as well as pyrolyzates. Pyrolysis of the silarylene-siloxanes showed markedly differing levels of silicon content in polymers with differing aromatic backbones and different levels of vinyl substitution.

  3. Separation of covalent hydrides by gas-solid chromatography

    International Nuclear Information System (INIS)

    A fully automated method was developed for separating the hydrides of elements of the IVth to VIIIth main subgroup of the periodic system and of Kr and Xe on the basis of their volatility using gas chromatography. The automated instrument allowing to carry out reduction, separation of the gaseous phase, the loading of a PORAPAK-packed column, the chromatographic separation and sampling was controlled by a HP 2116B computer. The elution time, peak area and the number of theoretical column plates were computed from chromatograms. The capture probably proceeded by a type of nonpolar nonspecific sorption (ΔH/Tsub(b) = 19.2 cal/mol.deg). The height of the theoretical plate was 0.05 to 0.1 cm. The technique may be used as a routine radiochemical method for group separations and for the separation of radioactive hydrides contained in the solution of targets irradiated with neutrons or charged particles in the preparation of radioactive sources of short-lived radionuclides, or in destructive activation analysis. (M.K.)

  4. Polyimide polymer glass-free capillary columns for gas chromatography.

    Science.gov (United States)

    Webster, Jackie G; Marine, Susan S; Danielson, Neil D

    2011-01-01

    Polymeric polyimide capillary tubing, both uncoated and coated with stationary phases of two polarities, is explored for use as capillary columns for gas chromatography (GC). These glass-free polyimide columns are flexible and their small winding diameter of less than a cm around a solid support makes them compatible for potential use in portable GC instruments. Polyimide columns with dimensions of 0.32 mm i.d. × 3 m are cleaned, annealed at 300°C, and coated using the static method with phenylmethylsilicone (PMS). Separations of volatile organics are investigated isothermally on duplicate sets of polyimide columns by GC with a flame ionization detector using split injection. Unlike the uncoated ones, the coated polyimide columns successfully separate Grob test mix classes of alkanes, amines, and fatty acid methyl esters. The relative standard deviations for retention time and peak area are 0.5 and 2.5 , respectively. With the 3 m PMS-coated column connected to a retention gap to permit operation at its optimum flow rate of 30 cm/s, a plate count of 3200 or plate height of 1 mm is possible. Lack of retention and tailing peaks are evident for the polyimide polymer capillary columns as compared to that of a 3 m commercial cross-linked PMS fused silica capillary. However, headspace analyses of an aromatic hydrocarbon mix and a Clearcoat automotive paint sample are viable applications on the PMS polyimide polymer column. PMID:21682994

  5. [Enantioseparation of 2-phenylcarboxylic acid esters by capillary gas chromatography].

    Science.gov (United States)

    Shi, Xueyan; Liu, Feipeng; Bian, Qinghua

    2016-01-01

    Chiral 2-arylcarboxylic acid derivatives are important intermediates for preparing 2-arylcarboxylic acids, which are non-steroidal anti-inflammatory drugs (NSAIDs). In order to separate 2-phenylcarboxylic acid ester enantiomers by capillary gas chromatography (CGC), 2, 6-di-O-pentyl-3-O-butyryl-β-cyclodextrin and 2,6-di-O-benzyl-3-O-heptanoyl-β-cyclodextrin were used as CGC chiral stationary phases, separately, and their enantioseparation abilities to enantiomers of methyl 2-phenylbutanoate, ethyl 2-phenylbutanoate, isopropyl 2-phenylbutanoate, methyl 2-phenylpropionate and cyclopentyl 2-phenylpropionate were examined. It was found that methyl 2-phenylbutanoate, methyl 2-phenylpropionate and cyclopentyl 2-phenylpropionate were successfully separated by using 2,6-di-O-pentyl-3-O-butyryl-β-cyclodextrin and 2,6-di-O-benzyl-3-O-heptanoyl-β-cyclodextrin as CGC chiral stationary phases, respectively. The enantiomer separation abilities of 2, 6-di-O-pentyl-3-O-butyryl-β-cyclodextrin to the three pairs of 2-phenylcarboxylic acid esters tested are superior to those of 2, 6-di-O-benzyl-3-O-heptanoyl-β-cyclodextrin. PMID:27319170

  6. DIRECT-DEPOSITION INFRARED SPECTROMETRY WITH GAS AND SUPERCRITICAL FLUID CHROMATOGRAPHY

    Science.gov (United States)

    A direct-deposition Fourier transform infrared (FT-IR) system has been evaluated for applicability to gas chromatography (GC) and supercritical fluid chromatography (SFC) of environmental analytes. A 100-um i.d. fused-silica transfer line was used for GC, and a 50-um transfer lin...

  7. Steroid monochloroacetates : Physical-chemical characteristics and use in gas-liquid chromatography

    NARCIS (Netherlands)

    Molen, H.J. van der; Groen, D.; Maas, J.H. van der

    1965-01-01

    Synthesis and physical-chemical characteristics (melting points, infrared-, visible- and ultraviolet spectra, paper-,thin-layer- and gas-liquid Chromatographie behaviour) of monochloroacetate derivatives of steroids representing the androstane-, pregnane-, estrane- and cholestane series are describe

  8. Analysis of chemical signals in red fire ants by gas chromatography and pattern recognition techniques

    Science.gov (United States)

    The combination of gas chromatography and pattern recognition (GC/PR) analysis is a powerful tool for investigating complicated biological problems. Clustering, mapping, discriminant development, etc. are necessary to analyze realistically large chromatographic data sets and to seek meaningful relat...

  9. Chemical Composition of Latent Fingerprints by Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    Hartzell-Baguley, Brittany; Hipp, Rachael E.; Morgan, Neal R.; Morgan, Stephen L.

    2007-01-01

    An experiment in which gas chromatography-mass spectrometry (GC-MS) is used for latent fingerprint extraction and analysis on glass beads or glass slides is conducted. The results determine that the fingerprint residues are gender dependent.

  10. Analysis of radioactive mixed hazardous waste using derivatization gas chromatography/mass spectrometry, liquid chromatography, and liquid chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Six samples of core segments from Tank 101-SY were analyzed for chelators, chelator fragments, and several carboxylic acids by derivatization gas chromatography/mass spectrometry. The major components detected were ethylenediaminetetraacetic acid, nitroso-iminodiacetic acid, nitrilotriacetic acid, citric acid, succinic acid, and ethylenediaminetriacetic acid. The chelator of highest concentration was ethylenediaminetetraacetic acid in all six samples analyzed. Liquid chromatography was used to quantitate low molecular weight acids including oxalic, formic, glycolic, and acetic acids, which are present in the waste as acid salts. From 23 to 61% of the total organic carbon in the samples analyzed was accounted for by these acids

  11. Isotope Fractionation in Methane Reactions Studied by Gas Chromatography and Liquid Scintillation

    DEFF Research Database (Denmark)

    Andersen, Bertel Lohmann; Bidoglio, G.; Leip, A.;

    1997-01-01

    Determination of C-14-marked methane by gas chromatography and liquid scintillation counting is shown to be useful in studies of isotope effects. Data on the specific activity is used to separate the contributions of (CH4)-C-14, and (CH4)-C-12 to the gas-chromatographic peak area. As an applicati...

  12. Applications of the gas chromatography in the nuclear science and technology

    International Nuclear Information System (INIS)

    This paper is a review on the applications of the gas chromatography in the nuclear science and technology published up to December 1971. Its contents has been classified under the following heads; I) Radiogaschromatography, II) Isotope separation, III) Preparation of labelled molecules, IV) Nuclear fuel cycle, V) Nuclear reactor technology, VI) Irradiation chemistry, VIl) Separation of me tal compounds in gas phase, VIII) Applications of the gas chromatography carried out at the Junta de Energia Nuclear, Spain. Arapter VIII only includes the investigations carried out from January 1969 to December 1971. Previous investigations in this field has been published elsewhere. (Author)

  13. Identification of bound alcohols in soil humic acids by gas chromatography-mass spectrometry

    OpenAIRE

    Berthier, Gersende; Dou, Sen; Peakman, Torren; Lichtfouse, Eric

    2000-01-01

    International audience Humic acids are complex, partly macromolecular, yellow-brownish substances occurring in soils, waters and sediments. In order to shed some light on their molecular structure, crop humic acids were cleaved by alkaline hydrolysis (KOH). The products were fractionated by thin layer chromatography to give mono-alcohols which were analysed as acetate derivatives by gas chromatography coupled to mass spectrometry. Linear alcohols, sterols, stanols and plant-derived triterp...

  14. Identification of Explosives from Porous Materials: Applications Using Reverse Phase High Performance Liquid Chromatography and Gas Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    C.J. Miller; G. Elias; N.C. Schmitt; C. Rae

    2010-06-01

    High performance liquid chromatography and gas chromatography techniques are well documented and widely used for the detection of trace explosives from organic solvents. These techniques were modified to specifically identify and quantify explosives extracted from various materials taken from people who had recently handled explosives. Documented techniques were modified to specifically detect and quantify RDX, TNT, and PETN from denim, colored flannel, vinyl, and canvas extracted in methanol using no sample cleanup prior to analysis. The methanol extracts were injected directly into several different column types and analyzed by HPLC-UV and/or GC-ECD. This paper describes general screening methods that were used to determine the presence of explosives in unknown samples and techniques that have been optimized for quantification of each explosive from the substrate extracts.

  15. Community air monitoring for pesticides-part 2: multiresidue determination of pesticides in air by gas chromatography, gas chromatography-mass spectrometry, and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Hengel, Matt; Lee, P

    2014-03-01

    Two multiresidue methods were developed to determine pesticides in air collected in California. Pesticides were trapped using XAD-4 resin and extracted with ethyl acetate. Based on an analytical method from the University of California Davis Trace Analytical Laboratory, pesticides were detected by analyzing the extract by gas chromatography-mass spectrometry (GC-MS) to determine chlorothalonil, chlorthal-dimethyl, cycloate, dicloran, dicofol, EPTC, ethalfluralin, iprodione, mefenoxam, metolachlor, PCNB, permethrin, pronamide, simazine, trifluralin, and vinclozolin. A GC with a flame photometric detector was used to determine chlorpyrifos, chlorpyrifos oxon, diazinon, diazinon oxon, dimethoate, dimethoate oxon, fonophos, fonophos oxon, malathion, malathion oxon, naled, and oxydemeton. Trapping efficiencies ranged from 78 to 92 % for low level (0.5 μg) and 37-104 % for high level (50 and 100 μg) recoveries. Little to no degradation of compounds occurred over 31 days; recoveries ranged from 78 to 113 %. In the California Department of Food and Agriculture (CDFA) method, pesticides were detected by analyzing the extract by GC-MS to determine chlorothalonil, chlorpyrifos, cypermethrin, dichlorvos, dicofol, endosulfan 1, endosulfan sulfate, oxyfluorfen, permethrin, propargite, and trifluralin. A liquid chromatograph coupled to a MS was used to determine azinphos-methyl, chloropyrifos oxon, DEF, diazinon, diazinon oxon, dimethoate, dimethoate oxon, diuron, EPTC, malathion, malathion oxon, metolachlor, molinate, norflurazon, oryzalin, phosmet, propanil, simazine and thiobencarb. Trapping efficiencies for compounds determined by the CDFA method ranged from 10 to 113, 22 to 114, and 56 to 132 % for 10, 5, and 2 μg spikes, respectively. Storage tests yielded 70-170 % recovery for up to 28 days. These multiresidue methods represent flexible, sensitive, accurate, and cost-effective ways to determine residues of various pesticides in ambient air. PMID:24370860

  16. Hyphenation of aqueous liquid chromatography to pyrolysis-gas chromatography and mass spectrometry for the comprehensive characterization of water-soluble polymers

    NARCIS (Netherlands)

    E.R. Kaal; M. Kurano; M. Geissler; H.-G. Janssen

    2008-01-01

    A recently developed hyphenated system for "organic" size-exclusion chromatography-pyrolysis-gas chromatography-mass spectrometry (SEC-Py-GC-MS) is adapted to allow the use of aqueous LC eluents as applied in the characterization of water-soluble polymers. The system uses syringe-based transfer of m

  17. Qualitative and quantitative analysis of vetiver essential oils by comprehensive two-dimensional gas chromatography and comprehensive two-dimensional gas chromatography/mass spectrometry.

    Science.gov (United States)

    Filippi, Jean-Jacques; Belhassen, Emilie; Baldovini, Nicolas; Brevard, Hugues; Meierhenrich, Uwe J

    2013-05-01

    Vetiver essential oils (VEO) are important raw ingredients used in perfume industry, entering the formula of numerous modern fragrances. Vetiver oils are considered to be among the most complex essential oils, resulting most of the time in highly coeluted chromatograms whatever the analytical technique. In this context, conventional gas chromatography has failed to provide a routine tool for the accurate qualitative and quantitative analysis of their constituents. Applying comprehensive two-dimensional gas chromatography techniques (GC×GC-FID/MS) afforded the mean to separate efficiently vetiver oil constituents in order to identify them in a more reliable way. Moreover, this is the first time that a complete true quantitation of each constituent is carried out on such complex oils by means of internal calibration. Finally, we have studied the influence of the injection mode on the determined chemical composition, and showed that several alcohols underwent dehydration under defined chromatographic conditions (splitless mode) usually recommended for quantitation purposes. PMID:23522261

  18. Characterization of odor-active compounds of various Chrysanthemum essential oils by gas chromatography-olfactometry, gas chromatography-mass spectrometry and their correlation with sensory attributes.

    Science.gov (United States)

    Xiao, Zuobing; Fan, Binbin; Niu, Yunwei; Wu, Minling; Liu, Junhua; Ma, Shengtao

    2016-01-15

    Volatiles of five kinds of Chrysanthemum essential oils with different manufactures were characterized by descriptive sensory analysis, gas chromatography-olfactometry (GC-O), gas chromatography-mass spectrometry (GC-MS) and statistics analysis. Six sensory attributes (floral, woody, grassy, fruity, sour and minty) were selected to assess Chrysanthemum essential oils. A total of 38 volatile compounds were detected and quantified using standard substances by GC-O and GC-MS. Terpenes constituted the largest chemical group among the volatiles of the essential oils. Then partial least squares regression (PLSR) was used to elucidate the relationship between sensory attributes and aroma compounds. The result showed that α-pinene, β-thujene, α-terpinolen, β-cubebene, caryophyllene, (Z)β-farnesene, (-)-spathulenol, linalool, camphor, camphene, 4-terpineol, Z-citral and 4-isopropyltoluene were typical aroma compounds covaried with characteristic aroma of Chrysanthemum essential oils. PMID:26735711

  19. Multiplex gas chromatography: an alternative concept for gas chromatographic analysis of planetary atmospheres

    Science.gov (United States)

    Valentin, J. R.

    1989-01-01

    Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan

  20. An analytical study by gas liquid chromatography and radiochromatography of tritium labelled lebaycid

    International Nuclear Information System (INIS)

    The stability and purity of the syntheses products of Lebaycid: 0,0 dime thylfosfochlorothionate and 4 methyl-thio-m-cresol were investigated by gas liquid chromatography. The study on (CH3O)2 PSC1 was made in a column of Silicone SE-30, Reoplex 400 using a thermal conductivity detector. The 99,4% pure product obtained from the preparative gas chromatograph was found to be stable within the duration of the experiment: seven months. (Author) 23 refs

  1. Perchloroethylene Analysis by Chemical Oxidation and Determination of Intermediate Products by Gas Chromatography, Mass Spectrometry

    OpenAIRE

    Sadeghi, M. (PhD; Naddafi, K. (PhD; Nabizadeh, R. (PhD

    2014-01-01

    Background and Objective: Perchloroethylene (PCE) is a chlorinated hydrocarbon used as a solvent in many industrial processes. In contaminated water and soil a great deal of PCE is found. This study aimed to determine the rate of decomposition of PCE occurred after advanced oxidation. Material and Methods: In this descriptive-analytic study conducted (2011) in public health faculty of Tehran University of medical sciences, gas chromatographic was used to measure PCE and gas chromatography - m...

  2. Chiral gas chromatography for the determination of 1,2-O-isopropylidene-sn-glycerol stereoisomers

    NARCIS (Netherlands)

    Dröge, M.J; Bos, R.; Woerdenbag, H.J.; Quax, Wim; Droge, MJ

    2003-01-01

    A stereospecific gas chromatography (GC) method using a (6-O-tButyldimethylsilyl-2,3-di-O-methyl)-beta-cyclodextrin as the chiral stationary phase has been developed and validated for the determination of the enantiomers of 1,2-O-isopropylidene-sn-glycerol (IPG), an important chiral synthon, in kine

  3. Planar gas chromatography column on aluminum plate with multi-walled carbon nanotubes as stationary phase

    Science.gov (United States)

    Platonov, I. A.; Platonov, V. I.; Pavelyev, V. S.

    2016-04-01

    The high selectivity of the adsorption layer for low-boiling alkanes is shown, the separation factor (α) couple iso-butane / butane is 1.9 at a column temperature of 50 °C.The paper presents sorption and selective properties of planar gas chromatography column on aluminum plate with multi-walled carbon nanotubes as the stationary phase.

  4. The Separation and Identification of Straight Chain Hydrocarbons: An Experiment Using Gas-Liquid Chromatography.

    Science.gov (United States)

    Benson, G. A.

    1982-01-01

    An experiment using gas-liquid chromatography is discussed, introducing the student to concept of dead volume and its measurement, idea and use of an internal reference compound, and to linear relationship existing between measurements of a separation on two different stationary phases. (Author/SK)

  5. A Robust Thermal Modulator for Comprehensive Two-Dimensional Gas Chromatography

    NARCIS (Netherlands)

    Geus, de H.J.; Boer, de J.

    1999-01-01

    In comprehensive two dimensional gas chromatography (GCxGC), two capillary columns are connected in series through an interface known as a 'thermal modulator'. This device transforms effluent from the first capillary column into a series of sharp injection-like chemical pulses suitable for high-spee

  6. Retention time locking procedure for comprehensive two-dimensional gas chromatography

    NARCIS (Netherlands)

    J. Mommers; J. Knooren; Y. Mengerink; A. Wilbers; R. Vreuls; S. van der Wal

    2011-01-01

    In gas chromatography (GC) reproducible retention times are in many cases highly favorable or in some cases even required. In one-dimensional GC, retention time shifts can be eliminated or minimized using a procedure called retention time locking (RTL). This procedure is based on adjusting the (cons

  7. Quantitative analysis of target components by comprehensive two-dimensional gas chromatography

    NARCIS (Netherlands)

    Mispelaar, V.G. van; Tas, A.C.; Smilde, A.K.; Schoenmakers, P.J.; Asten, A.C. van

    2003-01-01

    Quantitative analysis using comprehensive two-dimensional (2D) gas chromatography (GC) is still rarely reported. This is largely due to a lack of suitable software. The objective of the present study is to generate quantitative results from a large GC x GC data set, consisting of 32 chromatograms. I

  8. Tunable secondary dimension selectivity in comprehensive two-dimensional gas chromatography

    NARCIS (Netherlands)

    J. Mommers; G. Pluimakers; J. Knooren; T. Dutriez; S. van der Wal

    2013-01-01

    In this paper two tunable two-dimensional gas chromatography setups are compared and described in which the secondary dimension consists of two different capillary columns coupled in series. In the first setup the selectivity of the second dimension can be tuned by adjusting the effective column len

  9. The determination of cyclohexylamine in aqueous solutions of sodium cyclamate by electron-capture gas chromatography.

    Science.gov (United States)

    Solomon, M. D.; Pereira, W. E.; Duffield, A. M.

    1971-01-01

    A sensitive primary amine assay, capable of detecting 10 to the minus 11th g and utilizing the determination of the amine N-2,4-dinitrophenyl derivative by electron-capture gas chromatography is described. The method is exemplified by the determination of cyclohexylamine in sodium cyclamate.

  10. Impurity profiling of trinitrotoluene using vacuum-outlet gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    Brust, H.; Willemse, S.; Zeng, T.; Asten, A. van; Koeberg, M.; Heijden, A.E.D.M. van der; Bolck, A.; Schoenmakers, P.

    2014-01-01

    In this work, a reliable and robust vacuum-outlet gas chromatography-mass spectrometry (GC-MS) method is introduced for the identification and quantification of impurities in trinitrotoluene (TNT). Vacuum-outlet GC-MS allows for short analysis times the analysis of impurities in TNT was performed in

  11. Incorporation of Gas Chromatography-Mass Spectrometry into the Undergraduate Organic Chemistry Laboratory Curriculum

    Science.gov (United States)

    Giarikos, Dimitrios G.; Patel, Sagir; Lister, Andrew; Razeghifard, Reza

    2013-01-01

    Gas chromatography-mass spectrometry (GC-MS) is a powerful analytical tool for detection, identification, and quantification of many volatile organic compounds. However, many colleges and universities have not fully incorporated this technique into undergraduate teaching laboratories despite its wide application and ease of use in organic…

  12. Molecular Dynamic Study for Chiral Discrimination of a -Phenylethylamine by Modified Cyclodextrin in Gas Chromatography

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A molecular dynamic method in conjunction with a statistic test has been utilized to model chiral recognition of a -phenylethylamine on heptakis (2,6-di-O-butyl-3-O-butyryl)-b -cyclodextrin in gas chromatography. The modelling data correlated with the chromatographic elution order, and indicated that the preferred site of a -phenylethylamine is the interior of cavity.

  13. Datura stramonium poisoning. Identification of tropane alkaloids in urine by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Nogué, S; Pujol, L; Sanz, P; de la Torre, R

    1995-01-01

    A case of acute poisoning by ingestion of Datura stramonium infusion is reported. The patient presented with a typical anticholinergic syndrome (dryness of mouth, mydriasis, flushing, tachycardia, agitation, hallucinations) and was treated with symptomatic and supportive measures. The presence of tropane belladona alkaloids in a urine sample was demonstrated by gas chromatography-mass spectrometry. PMID:7601297

  14. A Gas Chromatography Experiment for Proving the Application of Quantum Symmetry Restrictions in Homonuclear Diatomic Molecules.

    Science.gov (United States)

    Dosiere, M.

    1985-01-01

    Background information, procedures used, and typical results obtained are provided for an experiment in which gas chromatography is used to prove the application of quantum symmetry restrictions in homonuclear diatomic molecules. Comparisons between experimental results and theoretical computed values show good agreement, within one to two…

  15. Surface energy characteristics of toner particles by automated inverse gas chromatography

    NARCIS (Netherlands)

    Segeren, L.H.G.J.; Wouters, M.E.L.; Bos, M.; Berg, van den J.W.A.; Vancso, G.J.

    2002-01-01

    Inverse gas chromatography (IGC) was applied to the surface energy study of surfaces of toner particles. The dispersive component of the surface energy was determined for three toner materials by infinite dilution IGC. The values obtained were comparable to the values obtained from contact angle exp

  16. Identification of Synthetic Polymers and Copolymers by Analytical Pyrolysis-Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Kusch, Peter

    2014-01-01

    An experiment for the identification of synthetic polymers and copolymers by analytical pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) was developed and performed in the polymer analysis courses for third-year undergraduate students of chemistry with material sciences, and for first-year postgraduate students of polymer sciences. In…

  17. High-voltage spark atomic emission detector for gas chromatography

    Science.gov (United States)

    Calkin, C. L.; Koeplin, S. M.; Crouch, S. R.

    1982-01-01

    A dc-powered, double-gap, miniature nanosecond spark source for emission spectrochemical analysis of gas chromatographic effluents is described. The spark is formed between two thoriated tungsten electrodes by the discharge of a coaxial capacitor. The spark detector is coupled to the gas chromatograph by a heated transfer line. The gas chromatographic effluent is introduced into the heated spark chamber where atomization and excitation of the effluent occurs upon breakdown of the analytical gap. A microcomputer-controlled data acquisition system allows the implementation of time-resolution techniques to distinguish between the analyte emission and the background continuum produced by the spark discharge. Multiple sparks are computer averaged to improve the signal-to-noise ratio. The application of the spark detector for element-selective detection of metals and nonmetals is reported.

  18. Advancement and application of gas chromatography isotope ratio mass spectrometry techniques for atmospheric trace gas analysis

    Science.gov (United States)

    Giebel, Brian M.

    2011-12-01

    The use of gas chromatography isotope ratio mass spectrometry (GC-IRMS) for compound specific stable isotope analysis is an underutilized technique because of the complexity of the instrumentation and high analytical costs. However stable isotopic data, when coupled with concentration measurements, can provide additional information on a compounds production, transformation, loss, and cycling within the biosphere and atmosphere. A GC-IRMS system was developed to accurately and precisely measure delta13C values for numerous oxygenated volatile organic compounds having natural and anthropogenic sources. The OVOCs include methanol, ethanol, acetone, methyl ethyl ketone, 2-pentanone, and 3-pentanone. Guided by the requirements for analysis of trace components in air, the GC-IRMS system was developed with the goals of increasing sensitivity, reducing dead-volume and peak band broadening, optimizing combustion and water removal, and decreasing the split ratio to the IRMS. The technique relied on a two-stage preconcentration system, a low-volume capillary reactor and water trap, and a balanced reference gas delivery system. Measurements were performed on samples collected from two distinct sources (i.e. biogenic and vehicle emissions) and ambient air collected from downtown Miami and Everglades National Park. However, the instrumentation and the method have the capability to analyze a variety of source and ambient samples. The measured isotopic signatures that were obtained from source and ambient samples provide a new isotopic constraint for atmospheric chemists and can serve as a new way to evaluate their models and budgets for many OVOCs. In almost all cases, OVOCs emitted from fuel combustion were enriched in 13C when compared to the natural emissions of plants. This was particularly true for ethanol gas emitted in vehicle exhaust, which was observed to have a uniquely enriched isotopic signature that was attributed to ethanol's corn origin and use as an alternative

  19. Determination of methane in ambient air by multiplex gas chromatography

    Science.gov (United States)

    Valentin, J. R.; Carle, G. C.; Phillips, J. B.

    1985-01-01

    A multiplex gas chromatographic technique for the determination of methane in ambient air over extended periods is reported. A modest gas chromatograph which uses air as the carrier gas was modified by adding a silver oxide sample modulator for multiplex operation. The modulator selectively catalyzes the decomposition of methane in air. The resulting analytical system requires no consumables beyond power. A profile of the methane concentration in this laboratory was obtained for an 8-day period. During this period, methane concentration varied with an approximately daily period from a low of 1.53 + or - 0.60 ppm to a high of 4.63 + or - 0.59 ppm over the entire 8 days. Some of the measured concentrations are higher than those reported elsewhere indicating the presence of some local source or sources for methane. This work has demonstrated the utility of a relatively simple multiplex gas chromatograph for the analysis of environmental samples. The technique should be applicable to other trace components in air through use of other selective modulators.

  20. Feasibility of the preparation of silica monoliths for gas chromatography: fast separation of light hydrocarbons.

    Science.gov (United States)

    Azzouz, Imadeddine; Essoussi, Anouar; Fleury, Joachim; Haudebourg, Raphael; Thiebaut, Didier; Vial, Jerome

    2015-02-27

    The preparation conditions of silica monoliths for gas chromatography were investigated. Silica-based monolithic capillary columns based on sol-gel process were tested in the course of high-speed gas chromatographic separations of light hydrocarbons mixture (C1-C4). The impact of modifying the amount of porogen and/or catalyst on the monolith properties were studied. At the best precursor/catalyst/porogen ratio evaluated, a column efficiency of about 6500 theoretical plates per meter was reached with a very good resolution (4.3) for very light compounds (C1-C2). The test mixture was baseline separated on a 70cm column. To our knowledge for the first time a silica-based monolithic capillary column was able to separate light hydrocarbons from methane to n-butane at room temperature with a back pressure in the range of gas chromatography facilities (under 4.1bar). PMID:25622518

  1. Determination of the trace TBP in industrial feed liquid by gas chromatography

    International Nuclear Information System (INIS)

    The determination of the trace TBP in kerosene of the industrial feed liquid by gas chromatography is studied in the paper. It first takes the purification treatment for the kerosene containing trace TBP. The plutonium is removed by 0.2 mol/L ferrous sulfamate-1 mol/L nitric acid using the back-extraction. The uranium and the nitric acid in the organic phase are removed by the deionized water. The impurity which affect the measurement of the TBP and is harmful to the gas chromatograph are eliminated. Then the content of the TBP of the organic phase can be determined by gas chromatography. Results show that the measuring range of the content of the TBP is 0.02% ∼ 2%. The precision of the method is better than 5% and the recovery is between 95%∼106%. (authors)

  2. Metal-Organic Framework Thin Films as Stationary Phases in Microfabricated Gas-Chromatography Columns.

    Energy Technology Data Exchange (ETDEWEB)

    Read, Douglas [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sillerud, Colin Halliday [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    The overarching goal of this project is to integrate Sandia's microfabricated gas-chromatography ( GC) columns with a stationary phase material that is capable of retaining high-volatility chemicals and permanent gases. The successful integration of such a material with GCs would dramatically expand the repertoire of detectable compounds for Sandia's various microanalysis systems. One such promising class of candidate materials is metal-organic frameworks (MOFs). In this report we detail our methods for controlled deposition of HKUST-1 MOF stationary phases within GC columns. We demonstrate: the chromatographic separation of natural gas; a method for determining MOF film thickness from chromatography alone; and the first-reported GC x GC separation of natural gas -- in general -- let alone for two disparate MOF stationary phases. In addition we determine the fundamental thermodynamic constant for mass sorption, the partition coefficient, for HKUST-1 and several light hydrocarbons and select toxic industrial chemicals.

  3. Hyphenated and comprehensive liquid chromatography × gas chromatography-mass spectrometry for the identification of Mycobacterium tuberculosis.

    Science.gov (United States)

    Mourão, Marta P B; Denekamp, Ilse; Kuijper, Sjoukje; Kolk, Arend H J; Janssen, Hans-Gerd

    2016-03-25

    Tuberculosis is one of the world's most emerging public health problems, particularly in developing countries. Chromatography based methods have been used to tackle this epidemic by focusing on biomarker detection. Unfortunately, interferences from lipids in the sputum matrix, particularly cholesterol, adversely affect the identification and detection of the marker compounds. The present contribution describes the serial combination of normal phase liquid chromatography (NPLC) with thermally assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) to overcome the difficulties of biomarker evaluation. The in-series combination consists of an LC analysis where fractions are collected and then transferred to the THM-GC-MS system. This was either done with comprehensive coupling, transferring all the fractions, or with hyphenated interfacing, i.e. off-line multi heart-cutting, transferring only selected fractions. Owing to the high sensitivity and selectivity of LC as a sample pre-treatment method, and to the high specificity of the MS as a detector, this analytical approach, NPLC × THM-GC-MS, is extremely sensitive. The results obtained indicate that this analytical set-up is able to detect down to 1 × 10(3) mycobacteria/mL of Mycobacterium tuberculosis strain 124, spiked in blank sputum samples. It is a powerful analytical tool and also has great potential for full automation. If further studies demonstrate its usefulness when applied blind in real sputum specimens, this technique could compete with the current smear microscopy in the early diagnosis of tuberculosis. PMID:26585206

  4. Hyphenation of supercritical fluid chromatography and two-dimensional gas chromatography-mass spectrometry for group type separations.

    Science.gov (United States)

    Potgieter, H; van der Westhuizen, R; Rohwer, E; Malan, D

    2013-06-14

    The Fischer-Tropsch (FT) process produces a variety of compounds over a wide carbon number range and the synthetic crude oil produced by this process is rich in highly valuable olefins and oxygenates, which crude oil only contains at trace levels. The characterization of these products is very challenging even when using comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-TOF-MS). The separation between cyclic paraffins and olefins is especially difficult since they elute in similar positions on the GC×GC chromatogram and since they have identical molecular masses with indistinguishable fragmentation patterns. Previously, a high performance liquid chromatography (HPLC) fractionation procedure was used prior to GC×GC-TOF-MS analysis to distinguish between alkenes and alkanes, both cyclic and non-cyclic, however, there was co-elution of the solvents used in the HPLC fractionation procedure, and the volatile components in the gasoline sample and the dilution introduced by the off-line fractionation procedure made it very difficult to investigate components present at very low concentrations. The hyphenation of supercritical fluid chromatography (SFC) to GC×GC is less complicated and the removal of the supercritical CO2 can be easily achieved without any loss of the volatile sample components, eliminating the introduction of co-eluting solvents as well as the dilution effect. This paper describes the on-line hyphenation of SFC to a GC×GC system in order to comprehensively characterize the chemical groups (saturates, unsaturates, oxygenates and aromatics) in an FT sample. PMID:23647609

  5. Determination of the Concentration of Atmospheric Gases By Gas Chromatography

    Directory of Open Access Journals (Sweden)

    Haskin, Chris

    2013-09-01

    Full Text Available The study of common greenhouse gases such as Carbon Dioxide (CO2 and Methane (CH4 is important because the concentration can be linked to added absorption of emitted terrestrial radiation, leading to the warming of the atmosphere1. This research measures the concentrations of common greenhouse gases in the air surrounding Eastern Michigan University. The development of an auto-sampler system for long term use on the EMU campus will create a viable way to monitor greenhouse gas concentrations throughout the year. Samples were analyzed using an Agilent 6890 Gas Chromatograph and a Valco Industries Thermal Conductivity Detector fitted with a Restek 5A Molsieve column (part # 80440- 800 and a Varian poraPLOT column (part# CP7550 for proper molecular separation. Molecular data analysis is plotted using Peaksimple software by SRI Systems from Torrance, Ca. Although the experiment is ongoing, preliminary data suggest this methodology could be used to detect atmospheric methane.

  6. Separation of hydrogen isotopes/helium using gas chromatography

    International Nuclear Information System (INIS)

    In the hydrogen isotope facility and the fuel cycle of the fusion reactor, an effective means for analyzing hydrogen isotopes and decay product (helium) of tritium is very important from the viewpoint of system operation and control. Chromatographic separation of the hydrogen isotopes/helium mixture was carried out by gas chromatograph at -196 .deg. C for quantitative analytical purpose. Neon and partially deactivated alumina were employed as the carrier gas and the fixed column, respectively. The chromatogram with complete separation was observed in order of He, H2 and D2 by the thermal conductivity detector. In addition, fairly good separation conditions were obtained in a shorter retention time without any appearance of nuclear spin isomers for the practical applications of the hydrogen isotope separation and analysis

  7. Development of an analytical method for estimating the composition of NOx gas using ion chromatography

    International Nuclear Information System (INIS)

    The choice of solvent for reprocessing the spent nuclear fuel by aqueous route is nitric acid. Hence the presence of NOx gas in all the off-gas streams is inevitable. Estimation of the composition of these gases is very important to evaluate the reaction mechanism of the dissolution step. This article briefly explains an analytical method developed for estimating the composition of NOx gas by ion chromatography during the reaction between sodium nitrate and nitric acid which can be extended for reprocessing applications in the PUREX dissolver system with necessary changes. (author)

  8. Determination of basic azaarenes and polynuclear aromatic hydrocarbons in airborne particulate matter by gas chromatography

    DEFF Research Database (Denmark)

    Nielsen, Torben; Clausen, Peraxel; Jensen, Finn Palmgren

    1986-01-01

    phase (adjusted to pH 14 with potassium hydroxide) with dichloromethane, and determined by capillary gas chromatography (g.c.) with a nitrogen-sensitive detector. The PAH in the toluene phase are isolated by means of semipreparative high-performance liquid chromatography and liquid-liquid extraction......Polynuclear aromatic hydrocarbons (PAH) and their nitrogen analogs, basic azaarenes, are extracted from samples of airborne particulate matter by toluene with ultrasonic treatment. The basic azaarenes are extracted from the toluene phase with phosphoric acid, re-extracted from the phosphoric acid...

  9. Determination of methyl tert-butyl ether (MTBE) in Chinese fuels by gas chromatography/mass spectrometry and gas chromatography/flame ionization detector

    Institute of Scientific and Technical Information of China (English)

    LIU Jie-min; CHENG Wei; WEN Mei-juan; JIANG Gui-bin

    2004-01-01

    A method was developed to determine the concentration of methyl tert-butyl ether(MTBE) in gasoline,diesel and heating oil by gas chromatography(GC) with mass spectrometry(GC-MS) or flame ionization detection (FID). The diluted gasoline was directly injected into the GC, and the complete separation of MTBE from co-eluting hydrocarbons was not required. GC/MS or GC/FID method can be used to analyze MTBE in different concentration range and have good consistency.

  10. Development, validation and determination of multiclass pesticide residues in cocoa beans using gas chromatography and liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Zainudin, Badrul Hisyam; Salleh, Salsazali; Mohamed, Rahmat; Yap, Ken Choy; Muhamad, Halimah

    2015-04-01

    An efficient and rapid method for the analysis of pesticide residues in cocoa beans using gas and liquid chromatography-tandem mass spectrometry was developed, validated and applied to imported and domestic cocoa beans samples collected over 2 years from smallholders and Malaysian ports. The method was based on solvent extraction method and covers 26 pesticides (insecticides, fungicides, and herbicides) of different chemical classes. The recoveries for all pesticides at 10 and 50 μg/kg were in the range of 70-120% with relative standard deviations of less than 20%. Good selectivity and sensitivity were obtained with method limit of quantification of 10 μg/kg. The expanded uncertainty measurements were in the range of 4-25%. Finally, the proposed method was successfully applied for the routine analysis of pesticide residues in cocoa beans via a monitoring study where 10% of them was found positive for chlorpyrifos, ametryn and metalaxyl. PMID:25442595

  11. Gas and high-performance liquid chromatography of phenols

    Energy Technology Data Exchange (ETDEWEB)

    Tesarova, E.; Pacakova, V.

    1983-05-01

    Gas (GC) and high-performance liquid chromatographic (HPLC) methods in the analysis of phenols are reviewed. Among the great number of phenolic compounds analyzed, alkylphenols, chlorophenols, dihydroxy-and trihydroxy-benzenes and biphenols are chiefly considered. The advantages and drawbacks of the methods are discussed. Relationships between the structural characteristics of phenols, the stationary phase structure, the mobile phase composition and the retention data are treated. Typical examples of the conditions for GC and HPLC analysis are summarized in tables. 276 references

  12. Liquid chromatography and supercritical fluid chromatography as alternative techniques to gas chromatography for the rapid screening of anabolic agents in urine.

    Science.gov (United States)

    Desfontaine, Vincent; Nováková, Lucie; Ponzetto, Federico; Nicoli, Raul; Saugy, Martial; Veuthey, Jean-Luc; Guillarme, Davy

    2016-06-17

    This work describes the development of two methods involving supported liquid extraction (SLE) sample treatment followed by ultra-high performance liquid chromatography or ultra-high performance supercritical fluid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS and UHPSFC-MS/MS) for the screening of 43 anabolic agents in human urine. After evaluating different stationary phases, a polar-embedded C18 and a diol columns were selected for UHPLC-MS/MS and UHPSFC-MS/MS, respectively. Sample preparation, mobile phases and MS conditions were also finely tuned to achieve highest selectivity, chromatographic resolution and sensitivity. Then, the performance of these two methods was compared to the reference routine procedure for steroid analyses in anti-doping laboratories, which combines liquid-liquid extraction (LLE) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). For this purpose, urine samples spiked with the compounds of interest at five different concentrations were analyzed using the three analytical platforms. The retention and selectivity of the three techniques were very different, ensuring a good complementarity. However, the two new methods displayed numerous advantages. The overall procedure was much faster thanks to high throughput SLE sample treatment using 48-well plates and faster chromatographic analysis. Moreover, the highest sensitivity was attained using UHPLC-MS/MS with 98% of the doping agents detected at the lowest concentration level (0.1ng/mL), against 76% for UHPSFC-MS/MS and only 14% for GC-MS/MS. Finally, the weakest matrix effects were obtained with UHPSFC-MS/MS with 76% of the analytes displaying relative matrix effect between -20 and 20%, while the GC-MS/MS reference method displayed very strong matrix effects (over 100%) for all of the anabolic agents.

  13. Liquid chromatography and supercritical fluid chromatography as alternative techniques to gas chromatography for the rapid screening of anabolic agents in urine.

    Science.gov (United States)

    Desfontaine, Vincent; Nováková, Lucie; Ponzetto, Federico; Nicoli, Raul; Saugy, Martial; Veuthey, Jean-Luc; Guillarme, Davy

    2016-06-17

    This work describes the development of two methods involving supported liquid extraction (SLE) sample treatment followed by ultra-high performance liquid chromatography or ultra-high performance supercritical fluid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS and UHPSFC-MS/MS) for the screening of 43 anabolic agents in human urine. After evaluating different stationary phases, a polar-embedded C18 and a diol columns were selected for UHPLC-MS/MS and UHPSFC-MS/MS, respectively. Sample preparation, mobile phases and MS conditions were also finely tuned to achieve highest selectivity, chromatographic resolution and sensitivity. Then, the performance of these two methods was compared to the reference routine procedure for steroid analyses in anti-doping laboratories, which combines liquid-liquid extraction (LLE) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). For this purpose, urine samples spiked with the compounds of interest at five different concentrations were analyzed using the three analytical platforms. The retention and selectivity of the three techniques were very different, ensuring a good complementarity. However, the two new methods displayed numerous advantages. The overall procedure was much faster thanks to high throughput SLE sample treatment using 48-well plates and faster chromatographic analysis. Moreover, the highest sensitivity was attained using UHPLC-MS/MS with 98% of the doping agents detected at the lowest concentration level (0.1ng/mL), against 76% for UHPSFC-MS/MS and only 14% for GC-MS/MS. Finally, the weakest matrix effects were obtained with UHPSFC-MS/MS with 76% of the analytes displaying relative matrix effect between -20 and 20%, while the GC-MS/MS reference method displayed very strong matrix effects (over 100%) for all of the anabolic agents. PMID:27185056

  14. Disposable reversed-phase chromatography columns for improved detection of carboxylic acids in body fluids by electron-capture gas-liquid chromatography.

    OpenAIRE

    Daneshvar, M. I.; Brooks, J B; Winstead, R M

    1987-01-01

    Disposable reversed-phase chromatography columns were tested for their effectiveness in removing unreacted trichloroethanol (TCE) from derivatized samples for gas-liquid chromatography analysis. Derivatized acidic chloroform extracts of saponified whole cells of Mycobacterium species, spent culture media, and derivatized acidic chloroform extracts of serum and cerebrospinal fluids from patients with tuberculous meningitis were tested. Samples were added to preconditioned reversed-phase chroma...

  15. Method development and validation for the determination of pesticides in green coffee by gas chromatography

    International Nuclear Information System (INIS)

    This study describes the implementation and validation of a multiresidue methodology for the determination of organochlorine, organophosphorus and pyrethroids pesticides in green coffee. Pesticides residues were extracted from green samples with an acetone-water (2:1) mixture followed by ethyl acetate cyclohexane (1:1) partitioning. The clean up steps include gel permeation chromatography and mini column chromatography using silica gel. Final determination was carried out by high-resolution gas chromatography with a pulsed split less injection mode and simultaneous detection by μ-ECD and NPD coupled in parallel. The methodology is specific, selective precise and accurate. Recoveries of majority of pesticides from spiked samples range from 70 to 110% at fortification levels of 0.038 mg/kg-1.536 mg/kg with limit of quantitation between 0.011 mg/kg and 0.100 mg/kg

  16. Quantitative analysis of abused drugs in physiological fluids by gas chromatography/chemical ionization mass spectrometry

    International Nuclear Information System (INIS)

    Methods have been developed for quantitative analysis of commonly abused drugs in physiological fluids using gas chromatography/chemical ionization mass spectrometry. The methods are being evaluated in volunteer analytical and toxicological laboratories, and analytical manuals describing the methods are being prepared. The specific drug and metabolites included in this program are: Δ9-tetrahydrocannabinol, methadone, phencyclidine, methaqualone, morphine, amphetamine, methamphetamine, mescaline, 2,5-dimethoxy-4-methyl amphetamine, cocaine, benzoylecgonine, diazepam, and N-desmethyldiazepam. The current analytical methods utilize relatively conventional instrumentation and procedures, and are capable of measuring drug concentrations as low as 1 ng/ml. Various newer techniques such as sample clean-up by high performance liquid chromatography, separation by glass capillary chromatography, and ionization by negative ion chemical ionization are being investigated with respect to their potential for achieving higher sensitivity and specificity, as well as their ability to facilitate simultaneous analysis of more than one drug and metabolite. (Auth.)

  17. Determination of Hydrocarbon Group-Type of Diesel Fuels by Gas Chromatography with Vacuum Ultraviolet Detection.

    Science.gov (United States)

    Weber, Brandon M; Walsh, Phillip; Harynuk, James J

    2016-06-01

    A GC-vacuum ultraviolet (UV) method to perform group-type separations of diesel range fuels was developed. The method relies on an ionic liquid column to separate diesel samples into saturates, mono-, di-, and polyaromatics by gas chromatography, with selective detection via vacuum UV absorption spectroscopy. Vacuum UV detection was necessary to solve a coelution between saturates and monoaromatics. The method was used to measure group-type composition of 10 oilsands-derived Synfuel light diesel samples, 3 Syncrude light gas oils, and 1 quality control sample. The gas chromatography (GC)-vacuum UV results for the Synfuel samples were similar (absolute % error of 0.8) to historical results from the supercritical fluid chromatography (SFC) analysis. For the light gas oils, discrepancies were noted between SFC results and GC-vacuum UV results; however, these samples are known to be challenging to quantify by SFC-flame ionization detector (FID) due to incomplete resolution between the saturate/monoaromatic and/or monoaromatic/diaromatic group types when applied to samples heavier than diesel (i.e., having a larger fraction of higher molecular weight species). The quality control sample also performed well when comparing both methods (absolute % error of 0.2) and the results agreed within error for saturates, mono- and polyaromatics. PMID:27125997

  18. Venus lower atmospheric composition - Analysis by gas chromatography

    Science.gov (United States)

    Oyama, V. I.; Carle, G. C.; Woeller, F.; Pollack, J. B.

    1979-01-01

    The first gas chromatographic analysis of the lower atmosphere of Venus is reported. Three atmospheric samples were analyzed. The third of these samples showed carbon dioxide (96.4 percent), molecular nitrogen (3.41 percent), water vapor (0.135 percent), molecular oxygen (69.3 ppm), argon (18.6 ppm), neon (4.31 ppm), and sulfur dioxide (186 ppm). The amounts of water vapor and sulfur dioxide detected are roughly compatible with the requirements of greenhouse models of the high surface temperature of Venus. The large positive gradient of sulfur dioxide, molecular oxygen, and water vapor from the cloud tops to their bottoms, as implied by Earth-based observations and these results, gives added support for the presence of major quantities of aqueous sulfuric acid in the clouds. A comparison of the inventory of inert gases found in the atmospheres of Venus, Earth, and Mars suggests that these components are due to outgassing from the planetary interiors.

  19. [Quantitative analysis of butachlor, oxadiazon and simetryn by gas chromatography].

    Science.gov (United States)

    Liu, F; Mu, W; Wang, J

    1999-03-01

    The quantitative analysis of the ingredients in 26% B-O-S (butachlor, oxadiazon and simetryn) emulsion by gas chromatographic method was carried out with a 5% SE-30 on Chromosorb AW DMCS, 2 m x 3 mm i.d., glass column at column temperature of 210 degrees C and detector temperature of 230 degrees C. The internal standard is di-n-butyl sebacate. The retentions of simetryn, internal standard, butachlor and oxadiazon were 6.5, 8.3, 9.9 and 11.9 min respectively. This method has a recovery of 98.62%-100.77% and the coefficients of variation of this analysis of butachlor, oxadiazon and simetryn were 0.46%, 0.32% and 0.57% respectively. All coefficients of linear correlation were higher than 0.999.

  20. Determination of 4-Chloroindole-3-Acetic Acid Methyl Ester in Lathyrus Vicia and Pisum by Gas Chromatography - Mass Spectrometry

    DEFF Research Database (Denmark)

    Engvild, Kjeld Christensen; Egsgaard, Helge; Larsen, Elfinn

    1980-01-01

    4-Chloroindole-3-acetic acid methyl ester was identified unequivocally in Lathyrus latifolius L., Vicia faba L. and Pisum sativum L. by thin layer chromatography, gas chromatography and mass spectrometry. The gas chromatographic system was able to separate underivatized chloroindole-3-acetic acid...... methyl ester isomers. The quantitative determination of 4-chloroindole-3-acetic acid methyl ester in immature seeds of these three species was performed by gas chromatography – mass spectrometry using deuterium labelled 4-chloro-indole-3-acetic acid methyl ester as an internal standard. P. sativum...

  1. Gas chromatography x gas chromatography-time-of-flight mass spectrometry analysis and antibacterial activity of essential oil from Amomum xanthophlebium

    International Nuclear Information System (INIS)

    Essential oils of fresh leaves, stem, rhizomes and whole aromatic plants of Amomum xanthophlebium (Zingiberaceae) were obtained by hydro distillation. Percentage yields of the leaf, stem and whole plant oils were 0.0032, 0.0074 and 0.0021 % whereas the rhizome oil obtained was very little. Chemical components of each oil and their percentages were determined by Gas Chromatography x Gas Chromatography-Time-of-Flight Mass Spectrometry (GCxGC-TOFMS). Analysis of A. xanthophlebium oils showed that they were dominated by terpenes. Main components in the leaves were allo-aromadendrene (3.41 %), (±)-globulol (2.58 %) and rosifoliol (2.55 %); stem, α-terpineol (4.25 %), rosifoliol (2.41 %) and bingpian (2.27 %); rhizomes, viridiflorol (5.72 %), (±)-globulol (5.23 %) and α-cadinol (4.81 %); whole plants, eucalyptol (4.11 %), l-α-terpineol (2.88 %) and rosifoliol (2.82 %). The stem oil of A. xanthophlebium showed antibacterial activity against Gram-negative Escherichia coli and Gram-positive methicillin-resistant Staphylococcus aureus (MRSA) at the minimum inhibitory concentration of 80 mg/ ml. (author)

  2. Differentiation of mint (Mentha haplocalyx Briq.) from different regions in China using gas and liquid chromatography.

    Science.gov (United States)

    Dong, Wenjiang; Ni, Yongnian; Kokot, Serge

    2015-02-01

    In this study, complex substances such as Mint (Mentha haplocalyx Briq.) samples from different growing regions in China were analyzed for phenolic compounds by high-performance liquid chromatography with diode array detection and for the volatile aroma compounds by gas chromatography with mass spectrometry. Chemometrics methods, e.g. principal component analysis, back-propagation artificial neural networks, and partial least squares discriminant analysis, were applied to resolve complex chromatographic profiles of Mint samples. A total of 49 aroma components and 23 phenolic compounds were identified in 79 Mint samples. Principal component analysis score plots from gas chromatography with mass spectrometry and high-performance liquid chromatography with diode array detection data sets showed a clear distinction among Mint from three different regions in China. Classification results showed that satisfactory performance of prediction ability for back-propagation artificial neural networks and partial least squares discriminant analysis. The major compounds that contributed to the discrimination were chlorogenic acid, unknown 3, kaempherol 7-O-rutinoside, salvianolic acid L, hesperidin, diosmetin, unknown 6 and pebrellin in Mint according to regression coefficients of the partial least squares discriminant analysis model. This study indicated that the proposed strategy could provide a simple and rapid technique to distinguish clearly complex profiles from samples such as Mint.

  3. Differentiation of mint (Mentha haplocalyx Briq.) from different regions in China using gas and liquid chromatography.

    Science.gov (United States)

    Dong, Wenjiang; Ni, Yongnian; Kokot, Serge

    2015-02-01

    In this study, complex substances such as Mint (Mentha haplocalyx Briq.) samples from different growing regions in China were analyzed for phenolic compounds by high-performance liquid chromatography with diode array detection and for the volatile aroma compounds by gas chromatography with mass spectrometry. Chemometrics methods, e.g. principal component analysis, back-propagation artificial neural networks, and partial least squares discriminant analysis, were applied to resolve complex chromatographic profiles of Mint samples. A total of 49 aroma components and 23 phenolic compounds were identified in 79 Mint samples. Principal component analysis score plots from gas chromatography with mass spectrometry and high-performance liquid chromatography with diode array detection data sets showed a clear distinction among Mint from three different regions in China. Classification results showed that satisfactory performance of prediction ability for back-propagation artificial neural networks and partial least squares discriminant analysis. The major compounds that contributed to the discrimination were chlorogenic acid, unknown 3, kaempherol 7-O-rutinoside, salvianolic acid L, hesperidin, diosmetin, unknown 6 and pebrellin in Mint according to regression coefficients of the partial least squares discriminant analysis model. This study indicated that the proposed strategy could provide a simple and rapid technique to distinguish clearly complex profiles from samples such as Mint. PMID:25431171

  4. Measuring fuel contamination using high speed gas chromatography and cone penetration techniques

    Energy Technology Data Exchange (ETDEWEB)

    Farrington, S.P.; Bratton, W.L. [Applied Research Associates, Inc., South Royalton, VT (United States); Akard, M.L. [Chromatofast, Inc., Ann Arbor, MI (United States)] [and others

    1995-10-01

    Decision processes during characterization and cleanup of hazardous waste sites are greatly retarded by the turnaround time and expense incurred through the use of conventional sampling and laboratory analyses. Furthermore, conventional soil and groundwater sampling procedures present many opportunities for loss of volatile organic compounds (VOC) by exposing sample media to the atmosphere during transfers between and among sampling devices and containers. While on-site analysis by conventional gas chromatography can reduce analytical turnaround time, time-consuming sample preparation procedures are still often required, and the potential for loss of VOC is not reduced. This report describes the development of a high speed gas chromatography and cone penetration testing system which can detect and measure subsurface fuel contamination in situ during the cone penetration process.

  5. [Determination of aromatics in light petroleum products by comprehensive two-dimensional gas chromatography].

    Science.gov (United States)

    Li, Yanyan

    2006-07-01

    In recent years, comprehensive two-dimensional gas chromatography (GC x GC) have been used widely, and the applications of this technique to many fields have already been reported. In the standard method of oil analysis, the concentrations of aromatics and naphthalene hydrocarbons in light petroleum products must be detected by more than two methods. Mono-aromatics, di-aromatics etc. in light petroleum products were detected only by comprehensive two-dimensional gas chromatography. After the proper selection of column system and optimization of chromatographic conditions, the method can achieve the group separations of paraffins, olefins, naphthenes, aromatics with 1 to 2 rings and some target components in light petroleum products with good reproducibility and good precision. The recoveries of standard compounds were 89.5% - 106.1%, and the relative standard deviations of repeatedly detecting the components were all lower than 5.8%. It took only 30 min to finish a determination. PMID:17017165

  6. Determination of alkyl methanesulfonates in doxazosin mesylate by gas chromatography-mass spectrometer

    Directory of Open Access Journals (Sweden)

    C Sitaram

    2011-01-01

    Full Text Available High sensitive rapid gas chromatography-mass spectrometry method for the determination of four carcinogenic alkyl methanesulfonates viz. methyl methanesulfonate, ethyl methanesulfonate, isopropyl methanesulfonate and n-butyl methanesulfonate in doxazosin mesylate has been presented by using selective ion monitoring mode. The optimum separation was achieved between methyl methanesulfonate, ethyl methanesulfonate, isopropyl methanesulfonate and n-butyl methanesulfonate on a DB-5 (30 m×0.32 mm×1.0 μm capillary column under programming temperature. Acetonitrile, water and ammonia (90:9:1 v/v/v mixture was used as diluent. Various factors involved in the gas chromatography-mass spectrometry method development are also presented. This method was validated as per International Conference on Harmonization guidelines. The limit of quantitation of methyl methanesulfonate, ethyl methanesulfonate, isopropyl methanesulfonate and n-butyl methanesulfonate is 6 ppm with respect to 30 mg/ml of doxazosin mesylate.

  7. Investigating Solvent Purity Utilizing Comprehensive Gas Chromatography: A Study of Acetones

    Energy Technology Data Exchange (ETDEWEB)

    Wahl, Jon H.; Bolz, Cinnamon DH; Wahl, Karen L.

    2010-04-01

    Broad spectrum chemical analysis of trace level components is a continuing challenge for any analytical chemist. This challenge is further confounded when chemical impurities may be present in common organic solvents or when chemical artifacts may be formed, produced and introduced during an analytical procedure. Minimizing and understanding these chemical artifacts, is critical for trace level detection and is crucial for unambiguous analytical results. Comprehensive gas chromatography is an excellent analytical tool to help address these complex mixture challenges. This work examines the impurities present in various acetone sources utilizing comprehensive gas chromatography. This work highlights the extreme variability possible in solvent sources and hence the importance of understanding the impurities that may confound an analytical method or result.

  8. [Determination of aromatics in light petroleum products by comprehensive two-dimensional gas chromatography].

    Science.gov (United States)

    Li, Yanyan

    2006-07-01

    In recent years, comprehensive two-dimensional gas chromatography (GC x GC) have been used widely, and the applications of this technique to many fields have already been reported. In the standard method of oil analysis, the concentrations of aromatics and naphthalene hydrocarbons in light petroleum products must be detected by more than two methods. Mono-aromatics, di-aromatics etc. in light petroleum products were detected only by comprehensive two-dimensional gas chromatography. After the proper selection of column system and optimization of chromatographic conditions, the method can achieve the group separations of paraffins, olefins, naphthenes, aromatics with 1 to 2 rings and some target components in light petroleum products with good reproducibility and good precision. The recoveries of standard compounds were 89.5% - 106.1%, and the relative standard deviations of repeatedly detecting the components were all lower than 5.8%. It took only 30 min to finish a determination.

  9. Determination of Fatty Acid in Asparagus by Gas Chromatography

    Directory of Open Access Journals (Sweden)

    Zehra HAJRULAI-MUSLIU

    2016-05-01

    Full Text Available Asparagus contain a lot of macronutrients and micronutrients including folate, dietary fibre (soluble and insoluble and phenolic compounds. Also asparagus is a good source of unsaturated linoleic and linolenic fatty acids which are precursors for Eicosapentanoic acid (EPA and Docosahexanoic acid (DHA. Unsaturated fatty acids have important biological effects and they have important role in human health. The objective of this study was to analyze fatty acid composition of asparagus as a potential source of linoleic and linolenic acid - a precursor for EPA and DHA. For this reason we analyzed fifty seven samples of asparagus collected from the local market. We used AOAC 996.06 method and analyses were performed with gas chromatograph with flame-ionization detector (GC-FID. The highest concentration of fatty acid in the asparagus was linoleic acid (C18:2n6 which content in asparagus is 25.620±1.0%. Also, asparagus is good source of -linolenic fatty acid (C18:3n3 and content of this fatty acid in asparagus is 8.840±0.3%. The omega-6 to omega-3 (n6/n3 ratio in asparagus was 3.19. Polyunsaturated fatty acids (PUFAs were higher than monounsaturated fatty acids (MUFAs, and from saturated fatty acids, palmitic acid was most frequent with 24.324±1.0%. From our study we can conclude that asparagus is very good source of unsaturated fatty acids, especially linoleic and linolenic fatty acids.

  10. Venus lower atmospheric composition: analysis by gas chromatography.

    Science.gov (United States)

    Oyama, V I; Carle, G C; Woeller, F; Pollack, J B

    1979-02-23

    The first gas chromatographic analysis of the lower atmosphere of Venus is reported. Three atmospheric samples were analyzed. The third of these samples showed carbon dioxide (96.4 percent), molecular nitrogen (3.41 percent), water vapor (0.135 percent), molecular oxygen [69.3 parts per million (ppm)], argon (18.6 ppm), neon (4.31 ppm), and sulfuir dioxide (186 ppm). The amounts of water vapor and sulfur dioxide detected are roughly compatible with the requirements of greenhouse models of the high surface temperature of Venus. The large positive gradient of sulfur dioxide, molecular oxygen, and water vapor from the clould tops to their bottoms, as implied by Earth-based observations and these resuilts, gives added support for the presence of major quantities of aqueous sulfuric acid in the clouds. A comparison of the inventory of inert gases found in the atmospheres of Venus, Earth, and Mars suggests that these components are due to outgassing from the planetary interiors. PMID:17833004

  11. Radiocarbon dating of organic compounds in sediments using preparative capillary gas chromatography (PCGC)

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Masao [Japan Marine Science and Technology Center, Yokosuka, Kanagawa (Japan); Shibata, Yasuyuki; Yoneda, Minoru; Mukai, Hitoshi; Tanaka, Atsushi; Uehiro, Takashi; Morita, Masatoshi [National Inst. for Environmental Studies, Tsukuba, Ibaraki (Japan); Kawamura, Kimitaka [Hokkaido Univ., Sapporo (Japan); Hirota, Masashi [National Inst. for Environmental Studies, Tsukuba, Ibaraki (Japan)

    2001-02-01

    CG-AMS system, combining two-dimensional gas chromatography and accelerator mass spectroscopy, has been developed for compound-specific carbon 14 measurement. Samples from shallow sea sediments in Sanbanse, Tokyo bay ware collected, six typical fatty acids were separated therefrom. Ages were estimated from the carbon 14 measurement. Acids of carbon number 15 and 16 has nearly contemporary age, whereas acids of carbon number 22 has age of 17000 years. (A. Yamamoto)

  12. Residual solvent determination by head space gas chromatography with flame ionization detector in omeprazole API

    OpenAIRE

    Saurabh Pandey; Preeti Pandey; Raj Kumar; Narendra Pal Singh

    2011-01-01

    Residual solvents in pharmaceutical samples are monitored using gas chromatography with head space. Based on good manufacturing practices, measuring residual solvents is mandatory for the release testing of all active pharmaceutical ingredients (API). The analysis of residual organic solvents (methanol, acetone, cyclohexane, dichloromethane, toluene) in Omeprazole, an active pharmaceutical ingredient was investigated. Omeprazole is a potent reversible inhibitor of the gastric proton pump H+/K...

  13. Fast methods for screening of trichothecenes in fungal cultures using gas chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Kristian Fog; Thrane, Ulf

    2001-01-01

    The paper presents a fast method for trichothecene profiling and chemotaxonomic studies in species of Fusarium, Stachybotrys, Trichoderma and Memnoniella. Micro scale extracted crude Fusarium extracts were derivatised using pentafluoropropionic anhydride and analysed by gas chromatography......-acetoxyscirpentriol, nivalenol, fusarenon-X, deoxynivalenol, 15-acetyl- deoxynivalenol and 3-acetyl-deoxynivalenol possible during a 23-min GC run. A slightly modified method could detect trichothecenes produced by Stachybotrys, Memnoniella and Trichoderma, by hydrolysing crude extracts prior to derivatisation...

  14. Measurement of Infinite Diluted Activity Coefficient of Solvents in Polymer by Inverse Gas Chromatography Method

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    @@1 INTRODUCTION Due to its short experimental time, little sample needed, suitable for broad temperature range, inverse gas chromatography (IGC) has been widely used to measure variety of properties of polymer systems, such as the intinite diluted activity coefficients of solvent in polymer, the glass transition temperature of polymer and the surface properties of polymer[1-5], etc. Those data have been used to develop the group contribution method for the prediction of thermodynamic proper-ties of polymer solution[6].

  15. Microfluidic Columns with Nanotechnology-Enabled Stationary Phases for Gas Chromatography

    OpenAIRE

    Shakeel, Hamza

    2015-01-01

    Advances in micro-electro-mechanical-systems (MEMS) along with nanotechnology based methods have enabled the miniaturization of analytical chemistry instrumentation. The broader aim is to provide a portable, low-cost, and low-power platform for the real-time detection and identification of organic compounds in a wide variety of applications. A benchtop gas chromatography (GC) system is considered a gold standard for chemical analysis by analytical chemists. Similarly, miniaturization of key G...

  16. The Application of Resonance-Enhanced Multiphoton Ionization Technique in Gas Chromatography Mass Spectrometry

    OpenAIRE

    2014-01-01

    Gas chromatography resonance-enhanced multiphoton ionization time-of-flight mass spectrometry (GC/REMPI-TOFMS) using a nanosecond laser has been applied to analyze the 16 polycyclic aromatic hydrocarbons (PAHs). The excited-state lifetime, absorption characters, and energy of electronic states of the 16 PAHs were investigated to optimize the ionization yield. A river water sample pretreated by means of solid phase extraction was analyzed to evaluate the performance of the analytical instrumen...

  17. Characterisation of the surface of a cellulosic multi-purpose office paper by inverse gas chromatography

    OpenAIRE

    Santos, J.M.R.C.A.; Gil, M. H.; Portugal, A. (A.); Guthrie, J. T.

    2001-01-01

    The surface of multi-purpose cellulosic office paper has been analysed by inverse gas chromatography (IGC). The parameters determined were the dispersive component of the surface free energy, the enthalpy of adsorption and the entropy of adsorption of polar and apolar probes, the Lewis acidity constant, Ka, and the Lewis basicity constant, Kb. It can be concluded that the dispersive component of the surface free energy, ?sd decreases with temperature, in the range 50–90°C. The temperature coe...

  18. The solubility parameter for biomedical polymers-Application of inverse gas chromatography.

    Science.gov (United States)

    Adamska, K; Voelkel, A; Berlińska, A

    2016-08-01

    The solubility parameter seems to be a useful tool for thermodynamic characterisation of different materials. The solubility parameter concept can be used to predict sufficient miscibility or solubility between a solvent and a polymer, as well as components of co-polymer matrix in composite biomaterials. The values of solubility parameter were determined for polycaprolactone (PCL), polylactic acid (PLA) and polyethylene glycol (PEG) by using different procedures and experimental data, collected by means of inverse gas chromatography. PMID:27155736

  19. Analysis of cherat coal by pyrolysis gas chromatography

    International Nuclear Information System (INIS)

    Flash pyrolysis of four representative coal samples from Cherat coal mines was studied in flowing nitrogen using quartz tubular reactor coupled to gas chromatograph with flame ionization detector. This techniques allows the on line monitoring of volatile organics released from coal during pyrolysis. The major products detected are CH/sub 4/, C/sub 2/H/sub 4/ + C/sub 2/H/sub 6/, C/sub 3/H sub 6/ + C/sub 3/H/sub 8, C/sub 4/H/sub 10 and C/sub 5/H/sub 12/. Ratios of total hydrocarbons obtained are at 700 degree C from A-5, A-4, B1 and B-6 coal samples are 3.25:2.49:3.53:1 respectively, and are characteristic of each coal. The effect of temperature on the total amount of hydrocarbons was studied over temperature range 500-800 degree C,. For all the coal samples the total amount of hydrocarbons increased with an increase in temperature and passed through a maximum. For B-6 coal samples the temperature of the maximum is 650 degree C, while for A-5, A-4 and B-1 coals, it has raised to 750 degree C. To measure the effect of inherent mineral matters on the production of hydrocarbons, pyrolysis experiments were performed at 700 degree C using raw and de-mineralized coal. Removal of inherent mineral matter showed variable effect on the total amount of observed hydrocarbon products. For coal samples A-5, A-4 and B-1 the removal of inherent mineral decrease the products yield by 15 %, 23.5% and 21.5% respectively, while for B-6 samples the acid treatment of raw coal has no effect on the products yield. (author)

  20. Preventive doping control analysis: Liquid and gas chromatography time-to-flight mass spectrometry for detection of designer steriods

    NARCIS (Netherlands)

    Georgakopoulos, C.G.; Vonaparti, A.; Stamou, M.; Kiousi, P.; Lyris, E.; Angelis, Y.S.; Tsoupras, G.; Wuest, B.; Nielen, M.W.F.; Panderi, I.; Koupparis, M.

    2007-01-01

    A new combined doping control screening method for the analysis of anabolic steroids in human urine using liquid chromatography/electrospray ionization orthogonal acceleration time-of-flight mass spectrometry (LCoaTOFMS) and gas chromatography/electron ionization orthogonal acceleration time-of-flig

  1. Examples of the use of preparatory gas-chromatography in the manufacture of labelled molecules

    International Nuclear Information System (INIS)

    Gas chromatography is the most commonly used in the analysis of volatile products. Certain works mention its use for preparatory purposes. Since organic labelled-molecule preparations are usually made in respect of quantities of the order of 1-10 mmole, it has been possible to use gas chromatography with very little alteration for the purification of C14-labelled molecules and their separation from complex reaction mixtures. The apparatus employed is briefly described. The chromatography columns used (diam.: 9-12 mm, length: approx. 4-6 m) made it possible to separate labelled products with boiling-points of up to 180o C and in quantities of approximately 100 mg to 1 g. The fractions detected by a conventional conductivity-cell device were condensed in traps cooled by liquid nitrogen. The radioactivity was not measured at the same time, as an ionization chamber capable of operating at up to 200oC is still only at the research stage. In all cases, the vector gas was helium and the stationary phase support was usually 80 mesh ''celite 545''. Examples are given of applications to the purification of acetone 1-3-C14, benzene C414 methyl or ethyl acrylate 2-3-C14 and butadiene D6, and to the separation of a mixture of aromatic hydrocarbures. (author)

  2. Determination of alkyl amines in atmospheric aerosol particles: a comparison of gas chromatography-mass spectrometry and ion chromatography approaches

    Directory of Open Access Journals (Sweden)

    R.-J. Huang

    2014-03-01

    Full Text Available In recent years low molecular weight alkyl amines have been recognized to play an important role in particle formation and growth in the lower atmosphere. However, major uncertainties are associated with their atmospheric processes, sources and sinks, mostly due to the lack of ambient measurements and the difficulties in accurate quantification of alkyl amines at trace level. In this study, we present the evaluation and optimization of two analytical approaches, i.e., gas chromatography-mass spectrometry (GC-MS and ion chromatography (IC, for the determination of alkyl amines in aerosol particles. Alkyl amines were converted to carbamates through derivatization with isobutyl chloroformate for GC-MS determination. A set of parameters affecting the analytical performances of the GC-MS approach, including reagent amount, reaction time and pH value, was evaluated and optimized. The accuracy is 84.3–99.1%, and the limits of detection obtained are 1.8–3.9 pg. For the IC approach, a solid phase extraction (SPE column was used to separate alkyl amines from interfering cations before IC analysis. 1–2% (v/v of acetone (or 2–4% (v/v of acetonitrile was added to the eluent to improve the separation of alkyl amines on the IC column. The limits of detection obtained are 2.1–15.9 ng and the accuracy is 55.1–103.4%. The lower accuracy can be attributed to evaporation losses of amines during the sample concentration procedure. Measurements of ambient aerosol particle samples collected in Hong Kong show that the GC-MS approach is superior to the IC approach for the quantification of primary and secondary alkyl amines due to its lower detection limits and higher accuracy.

  3. Ethanol as Internal Standard for Quantitative Determination of Volatile Compounds in Spirit Drinks by Gas Chromatography

    CERN Document Server

    Charapitsa, Siarhei V; Kulevich, Nikita V; Makoed, Nicolai M; Mazanik, Arkadzi L; Sytova, Svetlana N

    2012-01-01

    The new methodical approach of using ethanol as internal standard in gas chromatographic analysis of volatile compounds in spirit drinks in daily practice of testing laboratories is proposed. This method provides determination of volatile compounds concentrations in spirit drinks directly expressed in milligrams per liter (mg/L) of absolute alcohol according to official methods without measuring of alcohol strength of analyzed sample. The experimental demonstration of this method for determination of volatile compounds in spirit drinks by gas chromatography is described. Its validation was carried out by comparison with experimental results obtained by internal standard method and external standard method.

  4. Research on determining organic carbon in rock and mineral samples by gas chromatography

    International Nuclear Information System (INIS)

    The authors introduce results of research on transformation mechanism, temperature and time of organic carbon during analysis of rock and mineral samples by gas chromatography, as well as conditions for eliminating carbonate constituent that may produce carbon dioxide gas. The research has solved the problem of connecting the chemical processing and instrument determination. The newly-established method is characterized by high sensitivity, good exactitude, simple and fast operation, and may be applied to the determination of organic carbon in rock, mineral, as well as sediment samples

  5. Comprehensive verification of new method "Ethanol as Internal Standard" for determination of volatile compounds in alcohol products by gas chromatography

    CERN Document Server

    Charapitsa, Siarhei V; Markovsky, Mikhail G; Yakuba, Yurii F; Kotov, Yurii N

    2014-01-01

    Recently proposed new method "Ethanol as Internal Standard" for determination of volatile compounds in alcohol products by gas chromatography is investigated from different sides. Results of experimental study from three different laboratories from Belarus and Russian Federation are presented.

  6. Multiresidue analysis of pesticides in traditional Chinese medicines using gas chromatography - negative chemical ionization tandem mass spectrometry

    Science.gov (United States)

    In this study, a residue analysis method for the simultaneous determination of 107 pesticides in the traditional Chinese medicines (TCMs), Angelica sinensis, Angelica dahurica, Leonurus heterophyllus Sweet, Pogostemon cablin, and Lonicera japonica Thunb, was developed using gas chromatography couple...

  7. ENANTIOMER SEPARATION OF POLYCHLORINATED BIPHENYL ATROPISOMERS AND POLYCHLORINATED BIPHENYL RETENTION BEHAVIOR ON MODIFIED CYCLODEXTRIN CAPILLARY GAS CHROMATOGRAPHY COLUMNS

    Science.gov (United States)

    Seven commercially-available chiral capillary gas chromatography columns containing modified cyclodextrins were evaluated for their ability to separate enantiomers of the 19 stable chiral polychlorinated biphenyl (PCB) atropisomers, and for their ability to separate these enantio...

  8. Research on the separation properties of empty-column gas chromatography (EC-GC) and conditions for simulated distillation (SIMDIS)

    OpenAIRE

    Boczkaj, Grzegorz; Kamiński, Marian

    2013-01-01

    Previous studies have revealed it is possible to separate a high-boiling mixture by gas chromatography in empty fused-silica capillary tubing rather than in columns coated with stationary phase. Chromatographic separation occurs solely on the basis of the different boiling points of the substances separated. The high similarity of such separations to those in classic distillation seems advantageous when gas chromatography is used for simulated distillation. This paper presents results from fu...

  9. Analysis of trapped gas in 1E34 detonators by gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Warner, D.K.; Back, P.S.; Barnhart, B.V.

    1980-05-14

    A method was developed to extract and then analyze gas trapped in thermally aged 1E34 detonators. This gas was extracted into an evacuated volume and injected into a gas chromatograph for separation and quantitative analysis. To effect this gas extraction, a device was designed for puncturing the detonator cup and capturing the effused gas. Limited testing of five detonators in this device shows amounts of gas ranging from about 0.5 X 10 {sup -7} to 12 X 10 {sup - 7} moles.

  10. Separation and Detection of Toxic Gases with a Silicon Micromachined Gas Chromatography System

    Science.gov (United States)

    Kolesar, Edward S.; Reston, Rocky R.

    1995-01-01

    A miniature gas chromatography (GC) system was designed and fabricated using silicon micromachining and integrated circuit (IC) processing techniques. The silicon micromachined gas chromatography system (SMGCS) is composed of a miniature sample injector that incorporates a 10 microliter sample loop; a 0.9 meter long, rectangular shaped (300 micrometer width and 10 micrometer height) capillary column coated with a 0.2 micrometer thick copper phthalocyanine (CuPc) stationary phase; and a dual detector scheme based upon a CuPc-coated chemiresistor and a commercially available 125 micrometer diameter thermal conductivity detector (TCD) bead. Silicon micromachining was employed to fabricate the interface between the sample injector and the GC column, the column itself, and the dual detector cavity. A novel IC thin-film processing technique was developed to sublime the CuPc stationary phase coating on the column walls that were micromachined in the host silicon wafer substrate and Pyrex (r) cover plate, which were then electrostatically bonded together. The SMGCS can separate binary gas mixtures composed of parts-per-million (ppm) concentrations of ammonia (NH3) and nitrogen dioxide (NO2) when isothermally operated (55-80 degrees C). With a helium carrier gas and nitrogen diluent, a 10 microliter sample volume containing ammonia and nitrogen dioxide injected at 40 psi ((2.8 x 10(exp 5)Pa)) can be separated in less than 30 minutes.

  11. Gas Phase Chromatography of some Group 4, 5, and 6 Halides

    Energy Technology Data Exchange (ETDEWEB)

    Sylwester, Eric Robert

    1998-10-01

    Gas phase chromatography using The Heavy Element Volatility Instrument (HEVI) and the On Line Gas Apparatus (OLGA III) was used to determine volatilities of ZrBr{sub 4}, HfBr{sub 4}, RfBr{sub 4}, NbBr{sub 5}, TaOBr{sub 3}, HaCl{sub 5}, WBr{sub 6}, FrBr, and BiBr{sub 3}. Short-lived isotopes of Zr, Hf, Rf, Nb, Ta, Ha, W, and Bi were produced via compound nucleus reactions at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory and transported to the experimental apparatus using a He gas transport system. The isotopes were halogenated, separated from the other reaction products, and their volatilities determined by isothermal gas phase chromatography. Adsorption Enthalpy ({Delta}H{sub a}) values for these compounds were calculated using a Monte Carlo simulation program modeling the gas phase chromatography column. All bromides showed lower volatility than molecules of similar molecular structures formed as chlorides, but followed similar trends by central element. Tantalum was observed to form the oxybromide, analogous to the formation of the oxychloride under the same conditions. For the group 4 elements, the following order in volatility and {Delta}H{sub a} was observed: RfBr{sub 4} > ZrBr{sub 4} > HfBr{sub 4}. The {Delta}H{sub a} values determined for the group 4, 5, and 6 halides are in general agreement with other experimental data and theoretical predictions. Preliminary experiments were performed on Me-bromides. A new measurement of the half-life of {sup 261}Rf was performed. {sup 261}Rf was produced via the {sup 248}Cm({sup 18}O, 5n) reaction and observed with a half-life of 74{sub -6}{sup +7} seconds, in excellent agreement with the previous measurement of 78{sub -6}{sup +11} seconds. We recommend a new half-life of 75{+-}7 seconds for {sup 261}Rf based on these two measurements. Preliminary studies in transforming HEVI from an isothermal (constant temperature) gas phase chromatography instrument to a thermochromatographic (variable temperature

  12. Integrated gas and liquid chromatography tandem mass spectrometry for forensic engine lubricating oil identification

    International Nuclear Information System (INIS)

    This paper presented a method for rapid chemical characterization of engine lubricating oils. Motor oils typically contain up to 5 per cent additives, such as detergent, antifoamant, dispersant, emulsifier, antioxidant, friction modifier, colour stabilizer and corrosion inhibitors. Different lube oil products usually have either different additives in various concentrations. As such, the formulation of additives in lube oil products should provide fingerprint information for forensic oil identification. The characterization method used in this study was based on a newly developed fast solvent liquid-liquid sample extraction procedure that combined the use of both liquid chromatography tandem mass spectrometry (LC-MS) and gas chromatography-mass spectrometry (GC-MS) simultaneously together with gas chromatography flame ionization detection (GC-FID). The method was used on a blind sample testing of commercially available engine lubricating products. The sample extraction procedure involved extraction of additives into acidified acetonitrile, two hexane washes of hydrophobic components of lube oil, filtration, and dilution with solvents for GC and LC analysis. The new method proved to be rapid and easy to use. It enabled the identification of unknown additives and hydrocarbons in many different types of fresh lube oils. Further tests will be needed to determine if this method can be used on real-world weathered samples. The method is part of an ongoing effort to deal with mysterious chemical spills, an important aspect of environmental protection and emergency preparedness. 8 refs., 7 figs

  13. Trace Analysis of Boron in Nuclear Graphite by Means of Gas Chromatography

    International Nuclear Information System (INIS)

    No literature is available about the application of gas chromatography in trace analysis of boron in graphite. The following methods of transformation of boron into its volatile compounds are discussed: (a) Ignition of graphite in a stream of oxygen and subsequent transformation of boron oxide into volatile methyl borate which is then analysed on a Dilkens Aerograph H Model 96 gas chromatograph with silicone column and hydrogen as carrier (concentration method). (b) Extraction of boron from the graphite by means of sodium fluoride at 2800oC with simultaneous chlorination and trapping of boron trichloride, which is then analysed (direct method). A home-made gas chromatograph with a thermal conductivity detector and nitrogen as a carrier was used. The column was made of glass with a 20% (wt./wt.) fluorocarbon oil on kieselguhr. Special precautions were taken on account of the sensitivity of boron trichloride to moisture. (author)

  14. Quantitative structure retention relationship studies for predicting relative retention times of chlorinated phenols on gas chromatography

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    A new method of quantitative structure-retention relationship(QSRR) studies was reported for predicting gas chromatography(GC) relative retention times(RRTs) of chlorinated phenols (CPs) using a DB-5 column.Chemical descriptors were calculated from the molecular structure of CPs and related to their gas chromatographic RRTs by using multiple linear regression analysis.The proposed model had a multiple square correlation coefficient R2 = 0.970,standard error SE = 0.0472,and significant level P = 0.0000.The QSRR model also reveals that the gas chromatographic relative retention times of CPs are associated with physicochemical property interactions with the stationary phase,and influenced by the number of chlorine and oxygen in the CP melecules.

  15. DETERMINATION OF ACRYLAMIDE IN FOOD BY GAS AND LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY

    Directory of Open Access Journals (Sweden)

    Michaela Vieriková

    2010-07-01

    Full Text Available  Acrylamide in food was determined by gas chromatography - mass spectrometry (GC-MS after bromination of acrylamide and underivatized acrylamide was quantified by ultra performance liquid chromatography -mass spectrometry (UPLC-MS. Two different sample preparation methods were used and optimised. The GC-MS method was used for various food matrices like breads, potato crisps, potato crackers, french fries. The UPLC-MS method was used for analysis of coffee. The limit of detection and limit of quantification for acrylamide were 7 µg.kg-1 and 20 µg.kg-1 by GC-MS, 9 µg.kg-1  and 30 µg.kg-1 by UPLC-MS. For both methods the reproducibility, given as relative standard deviation was    doi:10.5219/61  

  16. A monolithically fabricated gas chromatography separation column with an integrated high sensitivity thermal conductivity detector

    International Nuclear Information System (INIS)

    The monolithic integration of a high sensitivity detector with a gas chromatography (GC) separation column creates many potential advantages over the discrete components of a traditional chromatography system. In miniaturized high-speed GC systems, component interconnections can cause crucial errors and loss of fidelity during detection and analysis. A monolithically integrated device would eliminate the need to create helium-tight interconnections, which are bulky and labor intensive. Additionally, batch fabrication of integrated devices that no longer require expensive and fragile detectors can decrease the cost of micro GC systems through economies of scale. We present the design, fabrication and operation of a monolithic GC separation column and detector. Our device is able to separate nitrogen, methane and carbon dioxide within 30 s. This method of device integration could be applied to the existing wealth of column geometries and chemistries designed for specialized applications.

  17. Application of high-temperature gas chromatography to the analysis of used frying fats

    Energy Technology Data Exchange (ETDEWEB)

    Aguirre, M.; Marmesat, S.; Ruiz Mendez, M. V.; Dobarganes, M. C.

    2010-07-01

    The determination of polar compounds is the most commonly applied technique in the analysis of used frying fats and oils. High-temperature gas chromatography allows for a quantitative determination of oxidized monomeric FAME and dimeric FAME thus giving extra information on oil degradation starting from the fraction of polar compounds. Polar compounds are trans esterified and methyl esters are separated in a VF-5ht Ultimetal column (150 degree centigrade -held for 5 min- rising at 5 degree centigrade min-1 to 370 degree centigrade and held for 5 min) using methyl tricosanoate as internal standard. Results are compared with those obtained by more complex alternative methodology using high-performance size-exclusion chromatography. (Author)

  18. Gas chromatography-mass spectrometry in the investigation of on-column dehydration of steroid hormones during gas-liquid chromatography.

    Science.gov (United States)

    Trafford, D J; Coldwell, R D; Makin, H L

    1991-01-01

    Some underivatized steroids when injected onto conventional packed columns for gas-liquid chromatography underwent varying degrees of dehydration. This problem was traced to the presence of small pieces of broken glass on the top of the column at the point of injection. This observation provoked an examination of the effect of pre-column dehydration on a number of different types of steroids. Powdered aluminium was placed in the injection liner of a Hewlett-Packard gas chromatograph fitted with an HP1 capillary column connected to a mass selective detector, and injections were made using a new high temperature septumless injection system at temperatures between 200 and 400 degrees C. 5 alpha-androstan-3 alpha-ol, a simple monofunctional C19 steroid chosen as a model to establish optimum conditions, underwent dehydration at injection temperatures greater than 250 degrees C and the product reached a maximum at 400 degrees C when no unchanged steroid was present. Monohydroxylated androgens and oestrogens underwent dehydration at 400 degrees C producing products whose mass spectra indicated they were monenes, although the position of the double bond could not be assigned. Polyfunctional androgens and oestrogens and corticosteroids underwent complex changes producing a number of products some of whose structures could not be determined. The dehydration products had the advantage that they had relatively intense high mass ions and for suitable steroids this might provide enhanced sensitivity of detection during mass fragmentography. In such cases dehydration was reproducible and straight line standard curves were obtained. C27 and C28 secosteroids (vitamins D2 and D3) and some of their metabolites (e.g. 25-hydroxyvitamin D) underwent efficient dehydration, again producing products with intense molecular ions. In the case of 24,25-dihydroxyvitamin D3 and 25,26-dihydroxyvitamin D3, dehydration produced different products which were easily resolved in the chromatographic

  19. Enantiomeric separation of organophosphorus pesticides by high-performance liquid chromatography, gas chromatography and capillary electrophoresis and their applications to environmental fate and toxicity assays.

    Science.gov (United States)

    Li, Ling; Zhou, Shanshan; Jin, Lixia; Zhang, Cheng; Liu, Weiping

    2010-05-15

    In recent years, the continuous evolution of the field of stereochemistry has produced a heightened awareness of the applications of pure enantiomers of agrochemicals. This review describes reports of the enantiomeric separation of commercial organophosphorus pesticides (OPs) and the applications of these methods to research on the enantioselectivity of the toxicity and environmental fate of these compounds. Chiral OPs can be analysed by high-performance liquid chromatography (HPLC), gas chromatography (GC), and capillary electrophoresis (CE). These different separation techniques for OP enantiomers are briefly discussed, and their applications are presented.

  20. Estimating Fatty Acid Composition of Infant Buccal Mucosal Cells by Capillary Gas Chromatography

    Institute of Scientific and Technical Information of China (English)

    CHEN Fei; ZHANG Wei-li; LI Fang; ZHU Xiao-dong; ZHU Jian-xing

    2008-01-01

    Long chain polyunsaturated fatty adds, i. e., docosahexaenoic acid (DHA or C22 : 6n -3), arachidonic acid (AA or C20 : 4n - 6) have been identified as essential fatty acids and play an important role in growth and development of infants. Mensurement of fatty acid composition is usually by collection of blood, but to obtain blood in infants is difficult. Nowadays, the fatty acid composition can be estimated by collecting buccal mucosal cells, which can avoid repeated blood sampling. The purpose of this paper is to compare the fatty acid composition of cheek calls with that of plasma and red blood cells (RBCs). In this study, twenty-seven infants were enrolled, and buccal mucosal cells and blood samples were obtained from these infants of the same time. Fatty acid composition of buccal mucesal cells, plasma and RBCs were measured by capillary gas chromatography. The results show that the contents of AA and DHA in the buccal mucosal cells are correlated well with that in the plasma [r=0.36 (P=0.042) and r=0.38 (P=0.033), respectively]. The ratio of AA to DHA is 1.32% in buccal mucosal cells, 1.60% in plasma and 1.55% in RBCs and there are no significant differences among groups (P = 0.134). It shows that the fatty acid composition in buccal mucosal cells can reflect the fat nutrition status in infants and can be detected by capillary gas chromatography. Estimating fatty acid composition of buccal mucosal cells in infants by capillary gas chromatography is feasible, and because of its noninvasiveness, it can be suitable for nutrition research in infants.

  1. Comparison of the quantification of caffeine in human plasma by gas chromatography and ELISA

    Directory of Open Access Journals (Sweden)

    A.B. Carregaro

    2001-06-01

    Full Text Available In the present study we evaluated the precision of the ELISA method to quantify caffeine in human plasma and compared the results with those obtained by gas chromatography. A total of 58 samples were analyzed by gas chromatography using a nitrogen-phosphorus detector and routine techniques. For the ELISA test, the samples were diluted to obtain a concentration corresponding to 50% of the absorbance of the standard curve. To determine whether the proximity between the I50 of the standard curve and that of the sample would bring about a more precise result, the samples were divided into three blocks according to the criterion of difference, in modulus, of the I50 of the standard curve and of the I50 of the sample. The samples were classified into three groups. The first was composed of 20 samples with I50 up to 1.5 ng/ml, the second consisted of 21 samples with I50 ranging from 1.51 to 3 ng/ml, and the third of 17 samples with I50 ranging from 3.01 to 13 ng/ml. The determination coefficient (R² = 0.999 showed that the data obtained by gas chromatography represented a reliable basis. The results obtained by ELISA were also reliable, with an estimated Pearson correlation coefficient of 0.82 between the two methods. This coefficient for the different groups (0.88, 0.79 and 0.49 for groups 1, 2 and 3, respectively showed greater reliability for the test with dilutions closer to I50.

  2. Macroporous polymer monoliths as second dimension columns in comprehensive two-dimensional gas chromatography: a feasibility study

    NARCIS (Netherlands)

    D. Peroni; R.J. Vonk; W. van Egmond; H.-G. Janssen

    2012-01-01

    When the typical column combinations are used, comprehensive two-dimensional gas chromatography (GC × GC) suffers from the impossibility to operate both dimensions at their optimum carrier gas velocities at the same time. This as a result of the flow mismatch caused by the different dimensions of th

  3. Simple, specific analysis of organophosphorus and carbamate pesticides in sediments using column extraction and gas chromatography

    Science.gov (United States)

    Belisle, A.A.; Swineford, D.M.

    1988-01-01

    A simple, specific procedure was developed for the analysis of organophosphorus and carbamate pesticides in sediment. The wet soil was mixed with anhydrous sodium sulfate to bind water and the residues were column extracted in acetone:methylene chloride (1:l,v/v). Coextracted water was removed by additional sodium sulfate packed below the sample mixture. The eluate was concentrated and analyzed directly by capillary gas chromatography using phosphorus and nitrogen specific detectors. Recoveries averaged 93 % for sediments extracted shortly after spiking, but decreased significantly as the samples aged.

  4. Validation of a method to determine methylmercury in fish tissues using gas chromatography

    International Nuclear Information System (INIS)

    We validated a method to determine methylmercury in fish tissues using gas chromatography with an electron capture detector as described by the Association of Official Analytical Chemist (AOAC) International. The linear curve range was 0.02 to 1 g/ml and linear correlation coefficient was 0.9979. A 1 mg/kg methylmercury-contaminated fish sample was analyzed 20 times to determine repeatability of the method. The quantification limit was 0.16 mg/kg and detection limit was 0.06 ppm. Fish samples contaminated with 0.2 to 10 mg/kg methylmercury showed recovery indexes from 94.66 to 108.8%

  5. Chemical characterization using gas chromatography/mass spectrometry of two extracts from Phyllanthus orbicularis HBK

    International Nuclear Information System (INIS)

    The objective of this paper was the chemical characterization of two extracts from Phyllanthus orbicularis HBK through gas chromatography/mass spectrometry. To this end, maceration with N-hexane and ethyl acetate was used to obtain the respective extracts. The study of the hexane extract identified 17 components in which hydrocarbonate structures prevailed, mainly cyclooctacosane. In the ethyl acetate extract, 19 compounds were detected, being the terpenoids the predominant, although the most abundant was sterol g-sitosterol. For the first time, the identified compounds are reported for this species

  6. Inverse gas chromatography. V - Computer simulation of diffusion processes on the column

    Science.gov (United States)

    Hattam, Paul; Munk, Petr

    1988-01-01

    The elution behavior of low molecular weight probes on inverse gas chromatography (IGC) columns is simulated using a computer. The IGC model is based on a polymer stationary phase of uniform thickness with a nonnegligible resitance to probe penetration. Three characteristic numbers are found to determine the whole process: Z(p) characterizing the distribution of the probe between phases, Z(f) describing the diffusion in the polymer phase, and Z(g) related to diffusion in the gaseous phase. For situations when Z(p)/Z(f) is less than 2, the standard evaluation procedures are virtually useless. The actual behavior of such systems is described.

  7. Determination of ketone bodies in blood by headspace gas chromatography-mass spectrometry

    DEFF Research Database (Denmark)

    Holm, Karen Marie Dollerup; Linnet, Kristian; Rasmussen, Brian Schou;

    2010-01-01

    A gas chromatography-mass spectrometry (GC-MS) method for determination of ketone bodies (ß-hydroxybutyrate, acetone, and acetoacetate) in blood is presented. The method is based on enzymatic oxidation of D-ß-hydroxybutyrate to acetoacetate, followed by decarboxylation to acetone, which...... was quantified by the use of headspace GC-MS using acetone-(13)C(3) as an internal standard. The developed method was found to have intra- and total interday relative standard deviations acetone+acetoacetate levels (~25 to 8300 µM) and D-ß-hydroxybutyrate levels (~30 to 16500 µM). Recovery values varied...

  8. Simultaneous determination of aliphatic hydrocarbons, PCBs and PCTs in pork liver by gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Barros, C. [Dept. de Quimica Analitica, Nutricion y Bromatologia, Area Nutricion y Bromatologia, Facultad de Farmacia, Santiago de Compostela (Spain); Alvarez Pineiro, M.E. [Inst. de Investigacion y Analisis Alimentarios, Lab. de Bromatologia, Facultad de Farmacia, Santiago de Compostela (Spain); Simal Lozano, J. [Dept. de Quimica Analitica, Nutricion y Bromatologia, Area Nutricion y Bromatologia, Facultad de Farmacia, Santiago de Compostela (Spain); Lage Yusty, M.A. [Inst. de Investigacion y Analisis Alimentarios, Lab. de Bromatologia, Facultad de Farmacia, Santiago de Compostela (Spain)

    1996-10-01

    A multicomponent extraction/concentration procedure has been developed for the enrichment of PCBs, PCTs and aliphatic hydrocarbons (pristane, C{sub 18}, C{sub 19}, C{sub 20}, C{sub 22}, C{sub 24}, C{sub 28}, C{sub 32} and C{sub 36}) in pork liver. These components of the enriched extract were then simultaneously determined by gas chromatography. Mean recoveries ranged from 81.5% for pristane to 93% for PCBs; CV % (0.9-6.7) indicated the method to be both precise and reproducible. (orig.)

  9. Serum acetaminophen assay using activated charcoal adsorption and gas chromatography without derivatization.

    Science.gov (United States)

    Jeevanandam, M; Novic, B; Savich, R; Wagman, E

    1980-01-01

    A quantitative assay of acetaminophen in serum has been developed. The drug, together with an internal standard 2-acetamidophenol, is adsorbed on activated charcoal and then extracted into a mixture of ethyl acetate and isopropanol. This extract is then analyzed, without any derivatization, by gas chromatography. The isothermal analysis yielded a good, highly reproducible separation. The drug peak was symmetrical and without any tailing. The peak height response ratio was found to be linear with concentrations ranging from 25-500 ng/L. No interference was observed with the various drugs or metabolites which are commonly encountered in human serum. PMID:7421146

  10. Determination of cocaine in brazilian paper currency by capillary gas chromatography/mass spectrometry

    Directory of Open Access Journals (Sweden)

    Enrico Di Donato

    2007-01-01

    Full Text Available The presence of illicit drugs such as cocaine and marijuana in US paper currency is very well demonstrated. However, there is no published study describing the presence of cocaine and/or other illicit drugs in Brazilian paper currency. In this study, Brazilian banknotes were collected from nine cities, extracted and analyzed by capillary gas chromatography/mass spectrometry, in order to investigate the presence of cocaine. Bills were extracted with deionized water followed by ethyl acetate. Results showed that 93% of the bills presented cocaine in a concentration range of 2.38-275.10 µg/bill.

  11. Determination of 17 β-Estradiol in Rabbit Plasma by Gas Chromatography with Flame Ionization Detection

    OpenAIRE

    Yilmaz, B.; Y Kadioglu

    2012-01-01

    This article describes gas chromatography-flame ionization detection method for determination of 17 β-estradiol in rabbit plasma. 17 β-estradiol and internal standard progesterone were extracted from plasma using liquid-liquid extraction method. Linearity was found between 0.25 and 20 μg/ml (r 2 =0.994) for plasma samples. Intra-day and inter-day precision, expressed as the relative standard deviation were less than 5.5%, and accuracy (relative error) was less than 3.5%. The mean recovery of ...

  12. Analysis of the citric acid cycle intermediates using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kombu, Rajan S; Brunengraber, Henri; Puchowicz, Michelle A

    2011-01-01

    Researchers view analysis of the citric acid cycle (CAC) intermediates as a metabolomic approach to identifying unexpected correlations between apparently related and unrelated pathways of metabolism. Relationships of the CAC intermediates, as measured by their concentrations and relative ratios, offer useful information to understanding interrelationships between the CAC and metabolic pathways under various physiological and pathological conditions. This chapter presents a relatively simple method that is sensitive for simultaneously measuring concentrations of CAC intermediates (relative and absolute) and other related intermediates of energy metabolism using gas chromatography-mass spectrometry.

  13. Detection for Non-Milk Fat in Dairy Product by Gas Chromatography

    OpenAIRE

    Kim, Ha-Jung; Park, Jung-Min; Lee, Jung-Hoon; Kim, Jin-Man

    2016-01-01

    The aim of this study was to evaluate the potential use of fatty acids, triacylglycerols, and cholesterol in the detection of adulterated milk fat. The fatty acid, triacylglycerol, and cholesterol profiles of the mixtures of milk and non-milk fat (adulteration ratios of 10%, 30%, 50%, 70%, and 90%) were analyzed by gas chromatography. The results showed that concentrations of the fatty acids with oleic acid (C18:1n9c) and linoleic acid (C18:2n6c), triglycerides with C52 and C54, and cholester...

  14. Detection of Clostridium difficile in faeces by direct gas liquid chromatography.

    OpenAIRE

    Levett, P N

    1984-01-01

    Stool specimens examined for the presence of Clostridium difficile and its cytotoxin were screened by gas liquid chromatography for the presence of volatile fatty acids and p-cresol. Twenty seven of 110 (25%) stools yielded C difficile or cytotoxin; iso-valeric acid was detected in 63/110 (57%) and iso-caproic acid in 18/110 (16%) stools. Para-cresol was found in 24/71 (34%) stools examined. Iso-valeric acid was detected in 85% of stools positive for C difficile, whereas iso-caproic acid (41%...

  15. Estimation of normal boiling points of trialkyl phosphates using retention indices by gas chromatography

    International Nuclear Information System (INIS)

    Retention indices of several homologous trialkyl phosphates have been determined by gas chromatography on different polar stationary phases namely, Apiezon L, SE-30 and XE-60. Normal boiling points of these trialkyl phosphates have been evaluated and compared with available literature values. Topological indices such as Xu index, atom type index and steric effect index are derived for these phosphates and have been correlated with the normal boiling points using multiple regression analysis. The influences of alkyl chain length, relative position of alkyl branching and steric factors on retention index are investigated and also the effect of polarity of the stationary phase on retention indices is discussed.

  16. Development of an apparatus for seaborgium studies by high temperature gas chromatography

    International Nuclear Information System (INIS)

    In preparation of experiments to characterize Sg as oxide hydroxide a new High Temperature On-Line Gas Chromatography Apparatus (HITGAS) based on the OLGA design was developed. The time-consuming recluster step was replaced by direct deposition of species leaving the chromatographic column on metal foils. In test experiments with short-lived Mo isotopes a retention time of 9 s was determined for an isothermal temperature of 1270 K, sufficiently short to study Sg isotopes 265Sg and 266Sg. A model based on the theory of supersonic expansion of gases and on simple geometric considerations reproduces the data of direct condensation experiments quite well

  17. Methods of analysis-Determination of pesticides in sediment using gas chromatography/mass spectrometry

    Science.gov (United States)

    Hladik, Michelle L.; McWayne, Megan M.

    2012-01-01

    A method for the determination of 119 pesticides in environmental sediment samples is described. The method was developed by the U.S. Geological Survey (USGS) in support of the National Water Quality Assessment (NAWQA) Program. The pesticides included in this method were chosen through prior prioritization. Herbicides, insecticides, and fungicides along with degradates are included in this method and span a variety of chemical classes including, but not limited to, chloroacetanilides, organochlorines, organophosphates, pyrethroids, triazines, and triazoles. Sediment samples are extracted by using an accelerated solvent extraction system (ASE®, and the compounds of interest are separated from co-extracted matrix interferences (including sulfur) by passing the extracts through high performance liquid chromatography (HPLC) with gel-permeation chromatography (GPC) along with the use of either stacked graphitized carbon and alumina solid-phase extraction (SPE) cartridges or packed Florisil®. Chromatographic separation, detection, and quantification of the pesticides from the sediment-sample extracts are done by using gas chromatography with mass spectrometry (GC/MS). Recoveries in test sediment samples fortified at 10 micrograms per kilogram (μg/kg) dry weight ranged from 75 to 102 percent; relative standard deviations ranged from 3 to 13 percent. Method detection limits (MDLs), calculated by using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), ranged from 0.6 to 3.4 μg/kg dry weight.

  18. Indirect hydrogen analysis by gas chromatography coupled to mass spectrometry (GC-MS).

    Science.gov (United States)

    Varlet, V; Smith, F; Augsburger, M

    2013-08-01

    Gas chromatography (GC) is an analytical tool very useful to investigate the composition of gaseous mixtures. The different gases are separated by specific columns but, if hydrogen (H2 ) is present in the sample, its detection can be performed by a thermal conductivity detector or a helium ionization detector. Indeed, coupled to GC, no other detector can perform this detection except the expensive atomic emission detector. Based on the detection and analysis of H2 isotopes by low-pressure chemical ionization mass spectrometry (MS), a new method for H2 detection by GC coupled to MS with an electron ionization ion source and a quadrupole analyser is presented. The presence of H2 in a gaseous mixture could easily be put in evidence by the monitoring of the molecular ion of the protonated carrier gas. PMID:23893637

  19. Design and construct of a new detector for gas chromatography based on continuous negative corona discharge.

    Science.gov (United States)

    Ghahfarokhi, M Sharifian; Khayamian, T

    2011-05-01

    In this work, a new detector was designed and constructed based on negative corona discharge. This detector can be used separately or as a detector in gas chromatography. The detector and chromatographic variables including cell temperature, gas flow rates, voltage between the two electrodes, and column temperature were optimized. Chloroform was used as a test compound to evaluate the performance of the detector. The detection limit of chloroform was obtained 0.78 ng∕ml and its dynamic range was over the range of 2-840 ng∕ml. The relative standard detection was about 6% for the limit of quantification. This detector is able to be used as an alternative for analysis of compounds containing electronegative elements. PMID:21639545

  20. ANALYSIS OF PENTACHLOROPHENOL IN WATER BY PURGE AND TRAP CONCENTRATOR COUPLED TO GAS CHROMATOGRAPHY

    Institute of Scientific and Technical Information of China (English)

    HuixiaLan; YuancaiChen; ZhonghaoChen

    2004-01-01

    It is convenient and time saving to analyze pentachlorophenol (PCP) in water by purge and trap concentrator coupled to gas chromatography that avoids employing a great deal of organic solvent. In this paper, the appropriate purge and trap conditions of PCP are determined: the trapped sorbent is TenaxGC; the purge gas is pure nitrogen and purge flow is 40ml/min; the purge time is 30min. A series of standard PCP water samples 5, 10, 50, 100, 200, 400, 800, 1000ppb are analyzed in order to obtain standard curve, and the linear regressive equation obtained is Y=109.65X-687.72, which correlation coefficient r is 0.9949. The precision of the method is determined with 0.5ppb PCP water sample, and the standard deviation measured is 3%. The detection limit for PCP is 0.2ppb.

  1. Rapid determination of cholesterol in milk and milk products by direct saponification and capillary gas chromatography.

    Science.gov (United States)

    Fletouris, D J; Botsoglou, N A; Psomas, I E; Mantis, A I

    1998-11-01

    A simple method is described for the determination of cholesterol in milk and milk products. Samples (0.2 g) are saponified in capped tubes with 0.5 M methanolic KOH solution by heating for 15 min at 80 degrees C. Water is added to the mixtures, and the unsaponifiable fractions are extracted with hexane to be further analyzed by capillary gas chromatography. Because of the rapid sample preparation and gas chromatographic procedures, a single sample can be analyzed in 30 min. Overall recovery was 98.6%, and the linearity was excellent for the fortification range examined. Precision data that were based on the variation within and between days suggested an overall relative standard deviation value of 1.4%. The method has been successfully applied to quantitate cholesterol in a variety of milk products.

  2. Determination of Water Content of Water-soluble Paints by Gas Chromatography

    Institute of Scientific and Technical Information of China (English)

    顾润南; 钦维民; 肖舸

    2003-01-01

    This paper describes the determination of water content of water-soluble paints by gas chromatography. The water in paints is extracted by dimethyl formamide (DMF) as a solvent.Isopropanol is used as an internal standard. The mixture is separated by low-speed centrifugation.Then a 1-uL sample of the supernatant from the prepared solution is injected into the gas chromatograph. The water content is determined by internal standard calibration curve. The rate of recovery of added standard of this method is more than 98%. Relative mean deviation is less than 3‰.The linearity of calibration curve is good and relativity coefficient is higher than 0.998.

  3. A micro-discharge photoionization detector for micro-gas chromatography

    International Nuclear Information System (INIS)

    We report on a small (20 × 10 mm) micromachined device for the detection of gases in micro-gas chromatography (GC). It incorporates a micro-discharge across a 20-μm gap, and a remote electrode in the micro cavity that generates an electrical signal corresponding to the photo-ionization of gaseous analytes in a stream of carrier gas. Multi-component mixtures were detected and the results compared to those obtained with a flame ionization detector. The minimum detectable limit is 350 pg.μL−1 of n-octane in air when applying a 1.4 mW discharge. The combination of wet etching of glass (as used for microfluidic channels) with a lift-off process for detector electrodes by a robust batch process results in a universal, non-destructive, and sensitive microdetector for micro-GC. (author)

  4. In situ search for organics by gas chromatography analysis: new derivatization / thermochemolysis approach

    Science.gov (United States)

    Geffroy, Claude; Buch, Arnaud; David, Marc; Aissat, Lyes; El Mufleh, Amel; Papot, S.; Sternberg, Robert

    Many organic molecules are present in interstellar clouds and might be carried to the early Earth by comets and meteorites during the heavy bombardment phase in the first few hundred million years of the solar system. It has been suggested that extraterrestrial organic material may well represent an important part of the organic material available for the origin of life. Until samples, brought by future space missions, are available on Earth, in situ measurements are one of the way to get unaltered and non-contaminated samples for analysis. The analytical technique has to be robust, sensitive and non-specific due to the large scope of targets molecules. The only currently flight qualified technique of analysis of organic molecules in space is gas chromatography (Viking, Cassini-Huygens, SAM-MSL, COSAC-Rosetta). The main objective of this work is to present a new approach with multi step analysis using derivatisation and thermochemolysis reagents for a one pot in situ analysis of volatile and refractory organics in surface or sub-surface samples (Mars, comets).Indeed, no single technology enables to identify all organic compounds because naturally occurring molecules have different polarities, molecular weights, being extractible or recalcitrant, bonded trapped or adsorbed on minerals. Thus, we propose to wider the scope of chemical reagent already validated for in situ wet chemistry such as MTBSTFA (Rodier et al. 2001, 2002), DMF-DMA (Rodier et al. 2002), or TMAH (Rodier et al, 2005, Geffroy-Rodier et al; 2009) to analyze enantiomers of amino acids, carbohydrates and lipids in a one pot several steps sub system using a multi reagent and multi step approach. Thus using a new derivatizing agent, we successfully identified twenty one amino acids including twelve of the twenty proteinic amino acids without inhibiting following multi step thermochemolysis. *Geffroy-Rodier C, Grasset L, Sternberg R. Buch A. Amblès A. (2009) Thermochemolysis in search for organics in

  5. Multiple inert gas elimination technique by micropore membrane inlet mass spectrometry--a comparison with reference gas chromatography.

    Science.gov (United States)

    Kretzschmar, Moritz; Schilling, Thomas; Vogt, Andreas; Rothen, Hans Ulrich; Borges, João Batista; Hachenberg, Thomas; Larsson, Anders; Baumgardner, James E; Hedenstierna, Göran

    2013-10-15

    The mismatching of alveolar ventilation and perfusion (VA/Q) is the major determinant of impaired gas exchange. The gold standard for measuring VA/Q distributions is based on measurements of the elimination and retention of infused inert gases. Conventional multiple inert gas elimination technique (MIGET) uses gas chromatography (GC) to measure the inert gas partial pressures, which requires tonometry of blood samples with a gas that can then be injected into the chromatograph. The method is laborious and requires meticulous care. A new technique based on micropore membrane inlet mass spectrometry (MMIMS) facilitates the handling of blood and gas samples and provides nearly real-time analysis. In this study we compared MIGET by GC and MMIMS in 10 piglets: 1) 3 with healthy lungs; 2) 4 with oleic acid injury; and 3) 3 with isolated left lower lobe ventilation. The different protocols ensured a large range of normal and abnormal VA/Q distributions. Eight inert gases (SF6, krypton, ethane, cyclopropane, desflurane, enflurane, diethyl ether, and acetone) were infused; six of these gases were measured with MMIMS, and six were measured with GC. We found close agreement of retention and excretion of the gases and the constructed VA/Q distributions between GC and MMIMS, and predicted PaO2 from both methods compared well with measured PaO2. VA/Q by GC produced more widely dispersed modes than MMIMS, explained in part by differences in the algorithms used to calculate VA/Q distributions. In conclusion, MMIMS enables faster measurement of VA/Q, is less demanding than GC, and produces comparable results. PMID:23869066

  6. Separation of cis- and trans-Asarone from Acorus tatarinowii by Preparative Gas Chromatography

    Directory of Open Access Journals (Sweden)

    H. L. Zuo

    2012-01-01

    Full Text Available A preparative gas chromatography (pGC method was developed for the separation of isomers (cis- and trans-asarone from essential oil of Acorus tatarinowii. The oil was primarily fractionated by silica gel chromatography using different ratios of petroleum ether and ethyl acetate as gradient elution solvents. And then the fraction that contains mixture of the isomers was further separated by pGC. The compounds were separated on a stainless steel column packed with 10% OV-101 (3 m × 6 mm, i.d., and then the effluent was split into two gas flows. One percent of the effluent passed to the flame ionization detector (FID for detection and the remaining 99% was directed to the fraction collector. Two isomers were collected after 90 single injections (5 uL with the yield of 178 mg and 82 mg, respectively. Furthermore, the structures of the obtained compounds were identified as cis- and trans-asarone by 1H- and 13C-NMR spectra, respectively.

  7. Differentiation of endogenous and exogenous steroids by gas chromatography-combustion-mass spectrometry isotope ratio

    International Nuclear Information System (INIS)

    Urinary steroids profiles are used to control the misuse of endogenous steroids such as testosterone and dihydrotestosterone. The testosterone/epistestosterone ratio, measured by Gas Chromatography-Mass Spectrometry, is used to control testosterone administration. When T/E ratio is higher than 4, consumption of testosterone or its precursors is suspected. Recent researches have demonstrated the effectiveness of Carbon Isotope Ratio Mass Spectrometry to detect and confirm endogenous steroids administration. The ratio of the two stable carbon isotopes 13C and 12C allows the differentiation of natural and synthetic steroids because synthetic steroids have lower 13C abundance. In fact, the carbon isotope ratios can be used to determine endogenous steroids administration even when testosterone/epistestosterone ratio is at its normal value. In the current work, some of the most important aspects related to differentiation of endogenous and exogenous steroids by means of Gas Chromatography-Combustion-Isotope Ratio Mass Spectrometry are discussed. Also, this article provides a review about the purification and sample preparation previous to the analysis, and diet effects on carbon isotope ratio of endogenous anabolics steroids is presented too

  8. Gas Chromatography Method of Cleaning Validation Process for 2-Propanol Residue Determination in Pharmaceutical Manufacturing Equipment

    Directory of Open Access Journals (Sweden)

    Łukasz Czubak

    2014-07-01

    Full Text Available Cleaning validation is an integral operation of good manufacturing practice in pharmaceutical industry. The aim of this study was to validate simple analytical method for detection of 2-propanol residue in equipment, which is likely contaminated with 2-propanol, usually used in the production area. The gas chromatography with flame ionization detection (GC-FID method was validated on a GC system using DB-FFAP capillary column at the flow rate of 4.9 mL/min. The calibration curve was linear over concentration range from 2.8µg/mL to 110.7µg/mL with a correlation coefficient equal to 0.99981. The detection limit (LOD and quantitation limit (LOQ were 1.1µg/mL and 2.8µg/mL, respectively. The simplicity of gas chromatography method makes it useful for routine analysis of 2-propanol residue and is an alternative to corresponding methods.

  9. Detection for Non-Milk Fat in Dairy Product by Gas Chromatography

    Science.gov (United States)

    2016-01-01

    The aim of this study was to evaluate the potential use of fatty acids, triacylglycerols, and cholesterol in the detection of adulterated milk fat. The fatty acid, triacylglycerol, and cholesterol profiles of the mixtures of milk and non-milk fat (adulteration ratios of 10%, 30%, 50%, 70%, and 90%) were analyzed by gas chromatography. The results showed that concentrations of the fatty acids with oleic acid (C18:1n9c) and linoleic acid (C18:2n6c), triglycerides with C52 and C54, and cholesterol detected are proportional to the adulteration ratios remarkably. Oleic acid (C18:1n9c), linoleic acid (C18:2n6c), C52, and C54 were lower in pure milk fat than in adulterated mixtures. In contrast, pure milk has a higher cholesterol concentration than all adulterated mixtures (adulteration concentration in the range 10-90%). Thus, we suggest that oleic acid (C18:1n9c), linoleic acid (C18:2n6c), C52, C54, and cholesterol are suitable indicators and can be used as biomarkers to rapidly detect adulterated milk fat by gas chromatography. This study is expected to provide basic data for adulteration and material usage. Moreover, this new approach can detect the presence of foreign oils and fats in the milk fat of cheese and can find application in related studies. PMID:27194929

  10. Assessment of Pesticide Residues in Some Fruits Using Gas Chromatography Coupled with Micro Electron Capture Detector

    Directory of Open Access Journals (Sweden)

    M. I. Bhanger

    2011-12-01

    Full Text Available A very sensitive analytical method for the determination of 26 pesticides in some fruits based on solid phase extraction (SPE cleanup was developed using gas chromatography (GC coupled with micro electron capture detector (μECD. The identity of the pesticides was confirmed by gas chromatography mass spectroscopy (GC-MS using selected ion monitoring (SIM mode. Ethyl acetate was used as a solvent for the extraction of pesticide residues with assistance of sonication. For cleanup an octadecyl, C18 SPE column was used. A linear response of μECD was observed for all pesticides with good correlation coefficients (>0.9992. Proposed method was successfully applied for the determination of pesticide residues in the orange, apple, and grape fruits. Average recoveries achieved for all of the pesticides at fortification levels of 0.05, 1.0 and 2.0 μg g-1 in analyzed fruits were above 90% with relative standard deviations (RSD less than 6

  11. Detection for Non-Milk Fat in Dairy Product by Gas Chromatography.

    Science.gov (United States)

    Kim, Ha-Jung; Park, Jung-Min; Lee, Jung-Hoon; Kim, Jin-Man

    2016-01-01

    The aim of this study was to evaluate the potential use of fatty acids, triacylglycerols, and cholesterol in the detection of adulterated milk fat. The fatty acid, triacylglycerol, and cholesterol profiles of the mixtures of milk and non-milk fat (adulteration ratios of 10%, 30%, 50%, 70%, and 90%) were analyzed by gas chromatography. The results showed that concentrations of the fatty acids with oleic acid (C18:1n9c) and linoleic acid (C18:2n6c), triglycerides with C52 and C54, and cholesterol detected are proportional to the adulteration ratios remarkably. Oleic acid (C18:1n9c), linoleic acid (C18:2n6c), C52, and C54 were lower in pure milk fat than in adulterated mixtures. In contrast, pure milk has a higher cholesterol concentration than all adulterated mixtures (adulteration concentration in the range 10-90%). Thus, we suggest that oleic acid (C18:1n9c), linoleic acid (C18:2n6c), C52, C54, and cholesterol are suitable indicators and can be used as biomarkers to rapidly detect adulterated milk fat by gas chromatography. This study is expected to provide basic data for adulteration and material usage. Moreover, this new approach can detect the presence of foreign oils and fats in the milk fat of cheese and can find application in related studies. PMID:27194929

  12. [Determination of residual glycol ethers in leather and leather products by gas chromatography/mass spectrometry].

    Science.gov (United States)

    Wang, Ghengyun; Zhang, Weiya; Li, Lixia; Shen, Yalei; Lin, Junfeng; Xie, Tangtang; Chu, Naiqing

    2014-08-01

    An effective method was established for the simultaneous determination of residual glycol ethers in leather and leather products by gas chromatography/mass spectrometry. Glycol ethers in leather and leather products were ultrasonically extracted at 45 °C, using ethyl acetate as the extraction solvent. The extracts were purified by solid phase extraction (SPE) columns, and then analyzed by gas chromatography/mass spectrometry in selected ion monitoring mode. The content of each analyte was calibrated by external standard method. The limit of detection of ethylene glycol ethyl ether (EGEE) was 0. 10 mg/kg under the condition of signal to noise (S/N) of 3 and the limits of the other 11 glycol ethers were all less than 0.05 mg/kg. The spiked recoveries varied from 81. 2% to 95. 5% at three different spiked levels with the relative standard deviations (RSDs) ranged from 1.4% to 6. 6%. The proposed method is simple, rapid and accurate, with the limits of detection much less than the requirements of the Regulation Concerning Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) of European Union. It is applicable to the determination of residual glycol ethers in leather and leather products, and provides a reference for the relevant testing standards.

  13. Quantification of residual solvents in antibody drug conjugates using gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Medley, Colin D., E-mail: medley.colin@gene.com [Genentech Inc., Small Molecule Pharmaceutical Sciences, 1 DNA Way, South San Francisco, CA 94080 (United States); Kay, Jacob [Research Pharmaceutical Services, 520 Virginia Dr. Fort, Washington, PA (United States); Li, Yi; Gruenhagen, Jason; Yehl, Peter; Chetwyn, Nik P. [Genentech Inc., Small Molecule Pharmaceutical Sciences, 1 DNA Way, South San Francisco, CA 94080 (United States)

    2014-11-19

    Highlights: • Sensitive residual solvents detection in ADCs. • 125 ppm QL for common conjugation solvents. • Generic and validatable method. - Abstract: The detection and quantification of residual solvents present in clinical and commercial pharmaceutical products is necessary from both patient safety and regulatory perspectives. Head-space gas chromatography is routinely used for quantitation of residual solvents for small molecule APIs produced through synthetic processes; however residual solvent analysis is generally not needed for protein based pharmaceuticals produced through cultured cell lines where solvents are not introduced. In contrast, antibody drug conjugates and other protein conjugates where a drug or other molecule is covalently bound to a protein typically use solvents such as N,N-dimethylacetamide (DMA), N,N‑dimethylformamide (DMF), dimethyl sulfoxide (DMSO), or propylene glycol (PG) to dissolve the hydrophobic small molecule drug for conjugation to the protein. The levels of the solvent remaining following the conjugation step are therefore important to patient safety as these parental drug products are introduced directly into the patients bloodstream. We have developed a rapid sample preparation followed by a gas chromatography separation for the detection and quantification of several solvents typically used in these conjugation reactions. This generic method has been validated and can be easily implemented for use in quality control testing for clinical or commercial bioconjugated products.

  14. [Determination of docosahexaenoic acid in milk powder by gas chromatography using acid hydrolysis].

    Science.gov (United States)

    Shao, Shiping; Xiang, Dapeng; Li, Shuang; Xi, Xinglin; Chen, Wenrui

    2015-11-01

    A method to determine docosahexenoic acid (DHA) in milk powder by gas chromatography was established. The milk powder samples were hydrolyzed with hydrochloric acid, extracted to get total fatty acids by Soxhlet extractor, then esterified with potassium hydroxide methanol solution to form methyl esters, and treated with sodium hydrogen sulfate. The optimal experiment conditions were obtained from orthogonal experiment L9(3(3)) which performed with three factors and three levels, and it requires the reaction performed with 1 mol/L potassium hydroxide solution at 25 degrees C for 5 min. The derivative treated with sodium hydrogen sulfate was separated on a column of SP-2560 (100 m x 0.25 mm x 0.20 μm), and determined in 55 min by temperature programming-gas chromatography. Good linearity was obtained in the range 5.0-300 mg/L with the correlation coefficient of 0.999 9. The relative standard deviations (RSDs) were 3.4%, 1.2% and 1.1% for the seven repeated experiments of 10, 50 and 100 mg/L of DHA, respectively. The limit of detection was 2 mg/kg, and the recoveries of DHA were in the range of 90.4%-93.5%. The results are satisfactory through the tests of practical samples. PMID:26939370

  15. Pyrolysis comprehensive two-dimensional gas chromatography study of petroleum source rock.

    Science.gov (United States)

    Wang, Frank Cheng-Yu; Walters, Clifford C

    2007-08-01

    Detailed compositional analyses of sedimentary organic matter can provide information on its biotic input, environment of deposition, and level of thermal maturation. Pyrolysis-gas chromatography (py-GC), often coupled with a mass spectrometer (py-GC/MS), is one technique used to provide this information. New developments in comprehensive two-dimensional gas chromatography (GC x GC or 2D-GC), coupled with pyrolysis (py-GC x GC), offer the prospect of providing more complete and quantitative compositional information of complex organic solids, such as kerogen and coals. This study will describe applications of pyrolysis-GC x GC to the characterization of petroleum source rocks using flame ionization detector (FID) and sulfur chemiluminescence detector (SCD). In the hydrocarbon analysis by FID, paraffins, naphthenes, and aromatics form distinct two-dimensional separated groups. In the analysis with SCD, sulfur-containing compounds can be distinguished as different classes, such as mercaptans, sulfides, thiophenes, benzothiophenes, and dibenzothiophenes. Single components or summed bands of homologous components can be analyzed qualitatively and quantitatively. With these detailed molecular fingerprints, the relations between kerogen composition and its biotic input, environment of deposition, and thermal maturation may be better understood. PMID:17585835

  16. Analytical Method Validation of an Herbal Formulation by Headspace Gas Chromatography Using QbD

    Directory of Open Access Journals (Sweden)

    Joydeep Mazumder

    2014-10-01

    Full Text Available Essential oils are rich sources of biologically active compounds possessing diverse medicinal properties. These form integral part of a number of herbal formulations. The most challenging part of commercialization of herbal formulation is to ensure consistency in quality from batch to batch. The aim of present study was to develop a validated gas chromatographic method based on quality by design (QbD for routine quality control purpose. A blend of essential oils possessing synergistic carminative properties was formulated in oily base. Ajowan oil, cardamom oil, caraway oil, coriander and fennel oil were selected for development of formulation. A gas chromatography method was developed for routine quality control purpose of the developed formulation by quality by design techniques (QbD. Each oil was characterized making use of a marker compound which was linalool for coriander oil, cineol for cardamom oil, anethol for fennel oil, carvone for caraway oil, thymol for ajowan oil and menthol for peppermint oil. Marker compound was characterized using mass spectroscopy. Chromatography method was established by quality by design approach and validated based on ICH guidelines.

  17. Method Development and Validation for Determining 1,3-Butadiene in Human Blood by Gas Chromatography-Mass Spectrometry and Head-Space Gas Chromatography%Method Development and Validation for Determining1,3-Butadiene in Human Blood by Gas Chromatography-Mass Spectrometry and Head-Space Gas Chromatography

    Institute of Scientific and Technical Information of China (English)

    ZHANG Su-jing; SHEN Bao-hua; ZHUO Xian-yi

    2013-01-01

    To develop a simple,validated method for identifying and quantifying 1,3-butadiene (BD) in human blood by gas chromatography-mass spectrometry (GC-MS) and head-space gas chromatography (HS-GC).BD was identified by GC-MS and HS-GC,and quantified by HS-GC.The method showed that BD had a good linearity from 50 to 500 μg/mL (r>0.99).The limits of detection and quantification were 10 μg/mL and 50 μg/mL,respectively.Both the intra-day precision and inter-day precision were <6.08%,and the accuracy was 96.98%-103.81%.The method was applied to an actual case,and the concentration of BD in the case was 242 μg/mL in human blood.This simple method is found to be useful for the routine forensic analysis of acute exposure to BD.

  18. Simultaneous determination of three organophosphorus pesticides in different food commodities by gas chromatography with mass spectrometry.

    Science.gov (United States)

    Vijaya Bhaskar Reddy, Ambavaram; Yusop, Zulkifli; Jaafar, Jafariah; Bin Aris, Azmi; Abdul Majid, Zaiton; Umar, Khalid; Talib, Juhaizah

    2016-06-01

    A sensitive and selective gas chromatography with mass spectrometry method was developed for the simultaneous determination of three organophosphorus pesticides, namely, chlorpyrifos, malathion, and diazinon in three different food commodities (milk, apples, and drinking water) employing solid-phase extraction for sample pretreatment. Pesticide extraction from different sample matrices was carried out on Chromabond C18 cartridges using 3.0 mL of methanol and 3.0 mL of a mixture of dichloromethane/acetonitrile (1:1 v/v) as the eluting solvent. Analysis was carried out by gas chromatography coupled with mass spectrometry using selected-ion monitoring mode. Good linear relationships were obtained in the range of 0.1-50 μg/L for chlorpyrifos, and 0.05-50 μg/L for both malathion and diazinon pesticides. Good repeatability and recoveries were obtained in the range of 78.54-86.73% for three pesticides under the optimized experimental conditions. The limit of detection ranged from 0.02 to 0.03 μg/L, and the limit of quantification ranged from 0.05 to 0.1 μg/L for all three pesticides. Finally, the developed method was successfully applied for the determination of three targeted pesticides in milk, apples, and drinking water samples each in triplicate. No pesticide was found in apple and milk samples, but chlorpyrifos was found in one drinking water sample below the quantification level. PMID:27095506

  19. Quantification of residual solvents in antibody drug conjugates using gas chromatography

    International Nuclear Information System (INIS)

    Highlights: • Sensitive residual solvents detection in ADCs. • 125 ppm QL for common conjugation solvents. • Generic and validatable method. - Abstract: The detection and quantification of residual solvents present in clinical and commercial pharmaceutical products is necessary from both patient safety and regulatory perspectives. Head-space gas chromatography is routinely used for quantitation of residual solvents for small molecule APIs produced through synthetic processes; however residual solvent analysis is generally not needed for protein based pharmaceuticals produced through cultured cell lines where solvents are not introduced. In contrast, antibody drug conjugates and other protein conjugates where a drug or other molecule is covalently bound to a protein typically use solvents such as N,N-dimethylacetamide (DMA), N,N‑dimethylformamide (DMF), dimethyl sulfoxide (DMSO), or propylene glycol (PG) to dissolve the hydrophobic small molecule drug for conjugation to the protein. The levels of the solvent remaining following the conjugation step are therefore important to patient safety as these parental drug products are introduced directly into the patients bloodstream. We have developed a rapid sample preparation followed by a gas chromatography separation for the detection and quantification of several solvents typically used in these conjugation reactions. This generic method has been validated and can be easily implemented for use in quality control testing for clinical or commercial bioconjugated products

  20. Hydrocarbons adsorption on metal trimesate MOFs: Inverse gas chromatography and immersion calorimetry studies

    International Nuclear Information System (INIS)

    Highlights: • Inverse gas chromatography and immersion calorimetry were compared on two MOFs. • Adsorption of seven carbon atoms adsorbates on Cu3(BTC)2 and Fe(BTC) was performed. • Size and polarizability of adsorbates are decisive in the strength of adsorption. • Dispersive interaction of surface free energy depends on the surface area. • Isp is influenced by the chemistry of adsorbates and morphology of the adsorbents. - Abstract: Two commercial metal-organic frameworks, Cu3(BTC)2 and Fe(BTC), have been selected to compare the adsorption parameters obtained on these materials by two different techniques: immersion calorimetry and inverse gas chromatography (IGC), in order to find a relationship between thermodynamic parameters obtained by so different techniques. From comparison between the enthalpy of adsorption obtained from IGC and the enthalpy of immersion, three molecules of the same number of carbon atoms have been selected: n-heptane, methylcyclohexane and toluene. Both by IGC and immersion calorimetry, the interaction is stronger in Fe(BTC), being the aromaticity of TOL determinant in the strength of the interaction. However, splitting of the enthalpy of adsorption into the dispersive and specific components allows to deduce that both parameters are more important on the Cu3(BTC)2, due to the higher available surface area in the case of the dispersive interaction; and for the specific interaction, due to the high potential of interaction into the micropores

  1. Determination of endogenous ethanol in blood and breath by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Jones, A W; Mårdh, G; Anggård, E

    1983-01-01

    We describe methods for the determination of endogenous ethanol in biological specimens from healthy abstaining subjects. The analytical methods were headspace gas chromatography (GC) for plasma samples and gas chromatography-mass spectometry (GC/MS) with deuterium labelled species 2H3-ethanol and 2H5-ethanol as internal standards for breath analysis. Ethanol in rebreathed air was about 10% higher than in directly analysed end-expired alveolar air. Known volumes of rebreathed air were passed through a liquid-N2 freeze trap and the volatile constituents of breath were concentrated prior to analysis by GC or GC/MS. Besides endogenous ethanol, peaks were seen on the chromatograms for methanol, acetone and acetaldehyde as well as several as yet unidentified substances. The endogenous alcohols ethanol and methanol were confirmed from their mass chromatograms and the GC/MS profile also indicated the presence of endogenous propan-1-ol. The concentration of endogenous ethanol in plasma showed wide inter-subject variations ranging from below detection limits to 1.6 micrograms/ml (34.8 mumol/l) and with mean +/- SD of 0.39 +/- 0.45 micrograms/ml (8.5 +/- 9.8 mumol/l). We aim to characterise further the role of endogenous ethanol with the main focus on dynamic aspects such as the rate of formation and turnover.

  2. Hydrocarbons adsorption on metal trimesate MOFs: Inverse gas chromatography and immersion calorimetry studies

    Energy Technology Data Exchange (ETDEWEB)

    Gutiérrez, Inés; Díaz, Eva; Vega, Aurelio [Department of Chemical and Environmental Engineering, University of Oviedo, Faculty of Chemistry, Julián Clavería s/n, 33006 Oviedo (Spain); Ordóñez, Salvador, E-mail: sordonez@uniovi.es [Department of Chemical and Environmental Engineering, University of Oviedo, Faculty of Chemistry, Julián Clavería s/n, 33006 Oviedo (Spain); Guerrero-Ruiz, Antonio [Department of Inorganic and technical Chemistry, UNED, 28040 Madrid (Spain); Castillejos-López, Eva; Rodríguez-Ramos, Inmaculada [Instituto de Catálisis y Petroleoquímica, CSIC, Madrid (Spain)

    2015-02-20

    Highlights: • Inverse gas chromatography and immersion calorimetry were compared on two MOFs. • Adsorption of seven carbon atoms adsorbates on Cu{sub 3}(BTC){sub 2} and Fe(BTC) was performed. • Size and polarizability of adsorbates are decisive in the strength of adsorption. • Dispersive interaction of surface free energy depends on the surface area. • I{sup sp} is influenced by the chemistry of adsorbates and morphology of the adsorbents. - Abstract: Two commercial metal-organic frameworks, Cu{sub 3}(BTC){sub 2} and Fe(BTC), have been selected to compare the adsorption parameters obtained on these materials by two different techniques: immersion calorimetry and inverse gas chromatography (IGC), in order to find a relationship between thermodynamic parameters obtained by so different techniques. From comparison between the enthalpy of adsorption obtained from IGC and the enthalpy of immersion, three molecules of the same number of carbon atoms have been selected: n-heptane, methylcyclohexane and toluene. Both by IGC and immersion calorimetry, the interaction is stronger in Fe(BTC), being the aromaticity of TOL determinant in the strength of the interaction. However, splitting of the enthalpy of adsorption into the dispersive and specific components allows to deduce that both parameters are more important on the Cu{sub 3}(BTC){sub 2}, due to the higher available surface area in the case of the dispersive interaction; and for the specific interaction, due to the high potential of interaction into the micropores.

  3. Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Highlights: · We determine methylmercury in serum and plasma using isotope dilution calibration. · Separation by gas chromatography and detection by inductively coupled plasma mass spectrometry. · Data for 50 specimens provides first reference range for methylmercury in serum. · Serum samples shown to be stable for 11 months in refrigerator. - Abstract: A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with 198Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) μg L-1 could be performed with uncertainty amplification factors -1 was estimated at 10 times the standard deviation of concentrations measured in preparation blanks. Within- and between-run relative standard deviations were -1, 0.35 μg L-1 and 2.8 μg L-1, with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; -1. This is the first time methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.

  4. Analysis of the photo catalytic degradation of the 4-chloro phenol and endosulfan by gas chromatography

    International Nuclear Information System (INIS)

    The water and soil pollution by organic compounds of considerable toxicity, is every time more alarming. The phenols and organo chlorinated compounds are some of the pollutants of more environmental concern. The present work shows the degradation by heterogeneous photo catalysis of the 4-chloro phenol and endosulfan in watery solutions using a photo reactor at laboratory scale, under ultraviolet irradiation as energy source and titanium dioxide TiO2 Degussa P25 as catalyst. Solutions of both compounds at concentrations of 10, 20, 30 and 40 mg/L were used, analyzing the more important operation parameters with those that the maxima degradation levels were reached. The analyzed variables were catalyst concentration and irradiation time, the analytical techniques of ultraviolet-visible spectroscopy and gas chromatography were used as process control. By means of ultraviolet-visible spectroscopy it was settled down that starting from the quantitative analysis, the 4-chloro phenol presented bigger degradation at smaller concentrations. Under the operation conditions mentioned in this work, it was observed that the photo catalytic processes obey a first order behavior in the chemical kinetics being adjusted to the Langmuir-Hinshelwood model (L-H). With the purpose of checking the degradation of the same ones it was used the gas chromatography, which is an advanced technique for the process pursuit, auxiliary in the quantification and analysis of the photo catalytic degradation of the 4-chloro phenol and endosulfan. It was based on the development and validation of the analytical method, by means of which was proven that the method is good and reliable in the research environment. The results of the quantitative analysis by gas chromatography and ultraviolet-visible, derived of the photo catalytic degradation of the 4-chloro phenol, in the maximum time of study (180 minutes), using the concentrations of 10, 20, 30 and 40 mg/L was found, by gas chromatography, a maximum

  5. Identification of Aroma-active Compounds in Essential Oil from Uncaria Hook by Gas Chromatography- Mass Spectrometry and Gas Chromatography-Olfactometry.

    Science.gov (United States)

    Iwasa, Megumi; Nakaya, Satoshi; Maki, Yusuke; Marumoto, Shinsuke; Usami, Atsushi; Miyazawa, Mitsuo

    2015-01-01

    The chemical composition of essential oil extracted from Uncaria Hook ("Chotoko" in Japanese), the branch with curved hook of the herbal medicine Uncaria rhynchophylla has been investigated by GC and GC-MS analyses. Eighty-four compounds, representing 90.8% of the total content was identified in oil obtained from Uncaria Hook. The main components i were (E)-cinnamaldehyde (13.4%), α-copaene (8.0%), methyl eugenol (6.8%), δ-cadinene (5.3%), and curcumene (3.6%). The important key aroma-active compounds in the oil were detected by gas chromatography-olfactometry (GC-O) and aroma extract dilution analysis (AEDA), using the flavor dilution (FD) factor to express the odor potency of each compounds. Furthermore, the odor activity value (OAV) has been used as a measure of the relative contribution of each compound to the aroma of the Uncaria Hook oil. The GC-O and AEDA results showed that α-copaene (FD = 4, OAV = 4376), (E)-linalool oxide (FD = 64, OAV = 9.1), and methyl eugenol (FD = 64, OAV = 29) contributed to the woody and spicy odor of Uncaria Hook oil, whereas furfural (FD = 8, OAV = 4808) contributed to its sweet odor. These results warrant further investigations of the application of essential oil from Uncaria Hook in the phytochemical and medicinal fields. PMID:26179003

  6. Simultaneous assessment of cholesterol absorption and synthesis in humans using on-line gas chromatography/ combustion and gas chromatography/pyrolysis/isotope-ratio mass spectrometry.

    Science.gov (United States)

    Gremaud, G; Piguet, C; Baumgartner, M; Pouteau, E; Decarli, B; Berger, A; Fay, L B

    2001-01-01

    A number of dietary components and drugs are known to inhibit the absorption of dietary and biliary cholesterol, but at the same time can compensate by increasing cholesterol synthesis. It is, therefore, necessary to have a convenient and accurate method to assess both parameters simultaneously. Hence, we validated such a method in humans using on-line gas chromatography(GC)/combustion and GC/pyrolysis/isotope-ratio mass spectrometry (IRMS). Cholesterol absorption was measured using the ratio of [(13)C]cholesterol (injected intravenously) to [(18)O]cholesterol (administered orally). Simultaneously, cholesterol synthesis was measured using the deuterium incorporation method. Our methodology was applied to 12 mildly hypercholesterolemic men that were given a diet providing 2685 +/- 178 Kcal/day (mean +/- SD) and 255 +/- 8 mg cholesterol per day. Cholesterol fractional synthesis rates ranged from 5.0 to 10.5% pool/day and averaged 7.36% +/- 1.78% pool/day (668 +/- 133 mg/day). Cholesterol absorption ranged from 36.5-79.9% with an average value of 50.8 +/- 15.4%. These values are in agreement with already known data obtained with mildly hypercholesterolemic Caucasian males placed on a diet similar to the one used for this study. However, our combined IRMS method has the advantage over existing methods that it enables simultaneous measurement of cholesterol absorption and synthesis in humans, and is therefore an important research tool for studying the impact of dietary treatments on cholesterol parameters.

  7. Detailed analysis of petroleum cuts by multidimensional gas chromatography; Analyse detaillee de coupes petrolieres par chromatographie en phase gazeuse multidimensionnelle

    Energy Technology Data Exchange (ETDEWEB)

    Vendeuvre, C.

    2006-01-15

    The limitations of petroleum resources implying a better valorisation of crude oil through the optimisation of production, refinery and petrochemistry processes, as well as the environmental regulations have strengthened the necessity of more detailed characterisation of petroleum products. In order to take up this challenge, efficient analytical tools have to be developed. This work demonstrates that comprehensive two-dimensional gas chromatography (GCxGC) constitutes a major advance compared to GC owing to its improved resolution power and to the structured chromatograms indicating the polarity and the volatility of hydrocarbons. The principle of GCxGC is based on the analysis of a whole sample in two independent dimensions of separation achieved using two GC columns of different selectivities; between the two columns a modulator device samples, focuses and re-injects small portions of the effluent from the first column into the second one. Since its introduction in 1991, GCxGC has known a rapid growth and has received a wide acceptance by the analytical science community. The competitive situation has considerably evolved during this thesis with the introduction of commercial systems and the two first sessions of an international symposium dedicated to this technique (Volendam, 2003 and Atlanta, 2004). The key points of the thesis concern the development of a GCxGC prototype system using dual jets CO{sub 2} technology and a data processing program; the evaluation of a retention model allowing a rational choice of operating conditions; and the application of this technique to various and complex issues. Thus, effluents from petrochemistry, refinery or pollution areas have been analysed according to the chemical classes of hydrocarbons and to their number of carbon atoms; a new method for obtaining distillation curves for each chemical group was also presented. Furthermore, the hyphenation of GCxGC with a specific sulphur detector revealed a great interest for

  8. Use of gas chromatography in the kinetics of decomposition of calcium carbonate

    International Nuclear Information System (INIS)

    Previous work has shown the utility of gas chromatography in studying the kinetics of the thermal composition of calcium carbonate. One of the advantages of this method is the possibility of characterizing and quantifying gaseous products by connecting a gas chromatograph at the exit of the reaction oven, which provides an easy system for studying the decomposition reaction. The calcium carbonate that was used was characterized by X-ray diffraction, scanning electron microscopy, BET surface area and particle size distribution by laser diffraction. The test conditions for the gas load flow in the reactor oven and the mass of calcium carbonate were determined at different reaction temperatures in order to eliminate the effect of diffusion on the speed of decomposition. The reactions were carried out with pro-analysis calcium carbonate in a quartz reactor, under isothermal conditions in a temperature range of 655oC to 715oC, using nitrogen as the gas load and with different sample masses. The gaseous products were analyzed at different reaction times and the instantaneous speed and rate of reaction were determined. The Flynn method was used to calculate the activation energy and the test results were adjusted with different kinetic models corresponding to solid state reactions. The area contracting model was the one that adjusted best (CW)

  9. Analysis of Diffusion Coefficient using Reversed-Flow Gas Chromatography-A Review

    Directory of Open Access Journals (Sweden)

    Khalisanni Khalid

    2011-01-01

    Full Text Available Problem statement: Since the earliest publication on the technique, Reversed-Flow Gas Chromatography (RF-GC has been used to determine physicochemical properties by measuring the value of one in the presence of another. The method is precise, accurate and simple compared to other conventional techniques. Approach: The experimental setup consists of a small modification of a commercial gas chromatograph, so that it includes a four- or six-port gas sampling valve and a simple cell placed inside the chromatographic oven. Results: This cell suppresses the effects of the carrier gas flow on the physicochemical occurrence taking place in the stationary phase. These phenomena pertain to rate coefficients and diffusion coefficients. Conclusion: The RF-GC methodologies can be considered as a wise instrumental approach to study the physicochemical phenomenon of liquid pollutants. It can be used to determine the rate coefficients and diffusion coefficients values of samples at various temperatures for the studies of environmental science and physical chemistry research areas. However, the methodologies are not restricted to the current fields of research. It is also relevant in the area of food chemistry, geochemistry, material science, nanotechnology, biological science and chemical technology.

  10. The fabrication of all-silicon micro gas chromatography columns using gold diffusion eutectic bonding

    Science.gov (United States)

    Radadia, A. D.; Salehi-Khojin, A.; Masel, R. I.; Shannon, M. A.

    2010-01-01

    Temperature programming of gas chromatography (GC) separation columns accelerates the elution rate of chemical species through the column, increasing the speed of analysis, and hence making it a favorable technique to speedup separations in microfabricated GCs (micro-GC). Temperature-programmed separations would be preferred in an all-silicon micro-column compared to a silicon-Pyrex® micro-column given that the thermal conductivity and diffusivity of silicon is 2 orders of magnitude higher than Pyrex®. This paper demonstrates how to fabricate all-silicon micro-columns that can withstand the temperature cycling required for temperature-programmed separations. The columns were sealed using a novel bonding process where they were first bonded using a gold eutectic bond, then annealed at 1100 °C to allow gold diffusion into silicon and form what we call a gold diffusion eutectic bond. The gold diffusion eutectic-bonded micro-columns when examined using scanning electron microscopy (SEM), scanning acoustic microscopy (SAM) and blade insertion techniques showed bonding strength comparable to the previously reported anodic-bonded columns. Gas chromatography-based methane injections were also used as a novel way to investigate proper sealing between channels. A unique methane elution peak at various carrier gas inlet pressures demonstrated the suitability of gold diffusion eutectic-bonded channels as micro-GC columns. The application of gold diffusion eutectic-bonded all-silicon micro-columns to temperature-programmed separations (120 °C min-1) was demonstrated with the near-baseline separation of n-C6 to n-C12 alkanes in 35 s.

  11. The fabrication of all-silicon micro gas chromatography columns using gold diffusion eutectic bonding

    International Nuclear Information System (INIS)

    Temperature programming of gas chromatography (GC) separation columns accelerates the elution rate of chemical species through the column, increasing the speed of analysis, and hence making it a favorable technique to speedup separations in microfabricated GCs (micro-GC). Temperature-programmed separations would be preferred in an all-silicon micro-column compared to a silicon-Pyrex® micro-column given that the thermal conductivity and diffusivity of silicon is 2 orders of magnitude higher than Pyrex®. This paper demonstrates how to fabricate all-silicon micro-columns that can withstand the temperature cycling required for temperature-programmed separations. The columns were sealed using a novel bonding process where they were first bonded using a gold eutectic bond, then annealed at 1100 °C to allow gold diffusion into silicon and form what we call a gold diffusion eutectic bond. The gold diffusion eutectic-bonded micro-columns when examined using scanning electron microscopy (SEM), scanning acoustic microscopy (SAM) and blade insertion techniques showed bonding strength comparable to the previously reported anodic-bonded columns. Gas chromatography-based methane injections were also used as a novel way to investigate proper sealing between channels. A unique methane elution peak at various carrier gas inlet pressures demonstrated the suitability of gold diffusion eutectic-bonded channels as micro-GC columns. The application of gold diffusion eutectic-bonded all-silicon micro-columns to temperature-programmed separations (120 °C min−1) was demonstrated with the near-baseline separation of n-C6 to n-C12 alkanes in 35 s

  12. DETERMINATION OF PERMEATION PROPERTIES OF GAS THROUGH POLYMER MEMBRANE BY GAS CHROMATOGRAPHY

    Institute of Scientific and Technical Information of China (English)

    JIN Xigao; FU Xiucheng; ZHAN Yongjian; QIAN Renyuan

    1987-01-01

    An apparatus constructed for measuring permeation properties of polymer membranes using a mixture of gases is described. A gas chromatographic system was applied to determine the individual transport characteristics of component gases without a vacuum line. This paper also discusses some experimental factors effecting the precision of measurement. The results show that there is a linear relationship between the permeation time and the volume of the gas permeated through the membrane within certain permeation period, which depends on the permeation rate (from 10-4 to 10-7 cm3 (STP)/cm2.sec. cmHg) of the membrane. The reproducibility has been found to be good with a relative standard deviation of 3.5%. This method is more sensitive, considerably faster and more convenient for determining both the permeability coefficient and the separation factor of a polymer membrane from a chromat ogram using mixed penetrant gases.

  13. Liquid chromatography "on-flow" 1H nuclear magnetic resonance on native glycosphingolipid mixtures together with gas chromatography/mass spectrometry on the released oligosaccharides for screening and characterisation of carbohydrate-based antigens from pig lungs.

    Science.gov (United States)

    Bäcker, A E; Thorbert, S; Rakotonirainy, O; Hallberg, E C; Olling, A; Gustavsson, M; Samuelsson, B E; Soussi, B

    1999-01-01

    Glycosphingolipids were prepared from pig lung and pooled into two fractions with (i) or = 3 sugar residues. Oligosaccharides were prepared and used for gas chromatography, gas chromatography/mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry. The glycolipid fractions i and ii were further characterised and purified using a novel method based on high performance liquid chromatography "on-flow" proton nuclear magnetic resonance. The LC "on-flow" NMR technique showed good chromatographic separation and gave NMR spectral information which could be used as guidance for pooling of the separated mixture glycolipids. Conventional 1H NMR, thin layer immunostaining, gas chromatography, gas chromatography/mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry were used to characterise the glycolipids and to validate LC-NMR spectral data.

  14. Determination of O6-butylguanine in DNA by immunoaffinity extraction/gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    A sensitive, specific, and rapid method for quantitating the minor adduct O6-butylguanine (O6BuG) in hydrolyzed DNA has been developed by combining immunoaffinity chromatography and high resolution gas chromatography-negative ion chemical ionization-mass spectrometry. Polyclonal antibodies raised against O6BuG were coupled to CNBr-activated Sepharose 4B and used for sample clean-up and extraction of the specific O6-alkylguanine. After addition of O6BuG and its deuterium labeled analogue (O6BuG-D7), used as internal standard, hydrolyzed DNA was applied on the immunoaffinity column and washed with water, and the immunoadsorbed butylated guanines were eluted with acetone/water cetome/water (95/5) before gas chromatographic derivatization. O6BuG and O6BuG-D7 were analyzed and quantitated by high resolution gas chromatography-negative ion chemical ionization-mass spectrometry as their pentafluorobenzyl-trimethylsilyl derivatives. Immunoaffinity column capacity and O6BuG recovery from this column were 1.53 nmol O6BuG/column and 62 +/- 5%, respectively. The method was applied to evaluate O6BuG levels in DNA butylated in vitro with 10 mM N-nitroso-Nr-butylurea or isolated from rats given an i.p. dose of 185 mg/kg N-nitroso-N-butylurea or N-nitrosodibutylamine. In the first case the level of modifications present in calf thymus DNA was 104 mumol O6BuG/mol guanine, and in the second case O6BuG in liver DNA was about 6 times higher after N-nitroso-N-butylurea (2.11 mumol O6BuG/mol guanine) than after N-nitrosodibutylamine (0.34 mumol O6BuG/mol guanine) treatment. These results indicate that O6BuG formed in vivo can be isolated and quantitated by this method, which may also be useful for studying DNA damage and repair mechanisms

  15. The Separation of Hydrogen Tritium and Tritium Hydride by Gas Chromatography

    International Nuclear Information System (INIS)

    Now that successful separation of hydrogen, deuterium and hydrogen deuteride has been achieved by gas chromatography, similar studies are being made dealing with mixtures of hydrogen, tritium and tritium hydride. Since tritium is used in tracer quantities the usual katharometer cannot be employed for its detection. This difficulty has been overcome by providing immediately following the katharometer a vibrating reed electrometer equipped with a high resistance leak which allows continuous monitoring of the activity of any tritium or tritium hydride emerging from the column by means of synchronized recorders. Separation of such mixtures has been tested with columns packed with palladium on silica, silica, alumina, and alumina coated with chromium oxide or ferric oxide. No effective separation was obtained with the palladium on silica column. Good separation was achieved with the plain silica column where hydrogen was employed as the carrier gas, but helium failed to elute the isotopes. Satisfactory results were obtained with the coated, partially deactivated alumina packing when helium or neon was the carrier gas, but the best separation was found with a column packing of uncoated activated alumina. Calibration with helium-tritium mixtures of known activity plus equilibrated hydrogen-tritium mixtures also of known activity allows quantitative estimation of tritium and tritium hydride. (author)

  16. Design for gas chromatography-corona discharge-ion mobility spectrometry.

    Science.gov (United States)

    Jafari, Mohammad T; Saraji, Mohammad; Sherafatmand, Hossein

    2012-11-20

    A corona discharge ionization-ion mobility spectrometry (CD-IMS) with a novel sample inlet system was designed and constructed as a detector for capillary gas chromatography. In this design, a hollow needle was used instead of a solid needle which is commonly used for corona discharge creation, helping us to have direct axial interfacing for GC-IMS. The capillary column was passed through the needle, resulting in a reaction of effluents with reactant ions on the upstream side of the corona discharge ionization source. Using this sample introduction design, higher ionization efficiency was achieved relative to the entrance direction through the side of the drift tube. In addition, the volume of the ionization region was reduced to minimize the resistance time of compounds in the ionization source, increasing chromatographic resolution of the instrument. The effects of various parameters such as drift gas flow, makeup gas flow, and column tip position inside the needle were investigated. The designed instrument was exhaustively validated in terms of sensitivity, resolution, and reproducibility by analyzing the standard solutions of methyl isobutyl ketone, heptanone, nonanone, and acetophenone as the test compounds. The results obtained by CD-IMS detector were compared with those of the flame ionization detector, which revealed the capability of the proposed GC-IMS for two-dimensional separation (based on the retention time and drift time information) and identification of an analyte in complex matrixes. PMID:23083064

  17. On-line gas-free electrodialytic eluent generator for capillary ion chromatography.

    Science.gov (United States)

    Yang, Bingcheng; Takeuchi, Masaki; Dasgupta, Purnendu K

    2008-01-01

    Both low- and high-pressure, gas-free, capillary-scale electrodialytic generators for eluents in ion chromatography are described. While the low-pressure devices rely on planar or tubular membranes, the high-pressure devices rely on ion-exchange beads used both as one-way ionic gates and as ball-on-seat valves to provide sealing. The high-pressure device is easily implemented in the form of a commercial cross fitting and can withstand at least 1400 psi. By design these devices do not produce gas in the eluent channel; hence, it is not necessary to remove gas afterward. With appropriate electrolytes and electrode polarities, such devices can produce either acid or base or salt. In regard to ionic transport, the behavior of these devices fully corresponds to that of a semiconductor diode. To our knowledge, this is the first time such complete equivalence of ion transport through ion-exchange media and with the more familiar example of electron transport through a semiconductor diode under both forward- and reverse-biased conditions have been demonstrated. Reverse bias can be applied to minimize/prevent Donnan-forbidden leakage or ion exchange. Even with 4 M KOH in the electrode compartments and 4 microL/min water flowing through the eluent channel, with a reverse bias of -12 V, the leakage KOH concentration is monolithic columns. PMID:18062705

  18. Microfluidic valve geometries and possibilities for flow switching in gas chromatography

    Science.gov (United States)

    Marriott, Philip J.; Eyres, Graham T.; Urban, Sylvia; Rühle, Christian

    2008-12-01

    Classical multi-(two-)dimensional separations in gas chromatography (GC) require switching systems to transfer the gas flow stream from the first to second dimension. This can be accomplished by valve systems, but is more suitably effected by pressure balanced systems, such as the Deans' switch method. Recent developments in microfluidics and related micro-technologies should make gas phase switching much more effective. The capillary flow technology platform of Agilent Technologies is an example of recent developments introduced to GC. Thus various Deans' switch pressure balanced devices, stream splitters, and column couplings bring new capabilities to analytical GC. We are uniquely placed to take advantage of the new devices, owing to our development of advanced operational methods in GC which can make use of microfluidic capillary couplings, and novel cryogenic approaches that deliver performance previously impossible with conventional methods. Multidimensional chromatographic flow switching to isolate pure compounds from complex mixtures suggests many potential applications for enhanced chemical analysis. Multiple dimensions of GC analysis, capabilities for integrating different spectroscopic detection methods for chemical identification of isolated chemical species including mass spectrometry, nuclear magnetic resonance and Fourier transform infrared, can be proposed. Applications in the essential oils and petrochemical area will be outlined.

  19. Determination of Hexachlorocyclohexane by Gas Chromatography Combined with Femtosecond Laser Ionization Mass Spectrometry

    Science.gov (United States)

    Yang, Xixiang; Imasaka, Tomoko; Li, Adan; Imasaka, Totaro

    2016-09-01

    Structural isomers and enantiomers of hexachlorocyclohexane (HCH) were separated using a chiral column by gas chromatography and quantitatively determined by multiphoton ionization mass spectrometry using an ultraviolet femtosecond laser (200 and 267 nm) as the ionization source. The order of elution of the enantiomers (i.e., (+)-α-HCH and (-)-α-HCH) was predicted from stabilization energies calculated for the complexes using permethylated γ-cyclodextrin as the stationary phase of the column, and the results were compared with the experimental data. The molecular ions observed for HCH were weak, even though they can be ionized through a process of resonance enhanced two-photon ionization at 200 nm. This unfavorable result can be attributed to the dissociation of the molecular ion, as predicted from quantum chemical calculations.

  20. Determination of long-chain fatty acids in serum by gas chromatography coupled to mass spectrometry

    International Nuclear Information System (INIS)

    The quantification of long-chain fatty acids is fundamental for the diagnosis of several peroxisome disorders, particularly those in which the β-oxidation peroxisome of fatty acids is affected. In this work the implementation of an analytical method for the determination of these markers in serum by gas chromatography coupled to mass spectrometry is described. Besides, samples from patients with a diagnostic impression of adrenoleukodystrophy linked to the X chromosome were analyzed. The necessary experimental conditions were achieved for the separation and quantification of C22:0, C24:0 and C26:0 fatty acids in serum, which are biochemical markers of various peroxisome diseases. The application of this method allowed confirming the diagnosis of three patients with a diagnostic impression of adrenoleukodystrophy linked to the X chromosome. The application of the method in daily practice will allow the Cuban medical system to count on a new laboratory parameter for the diagnosis of peroxisome disorders

  1. Diagnosis of propionic acidemia by gas chromatography coupled to mass spectrometry in a case analysis

    International Nuclear Information System (INIS)

    Propionic acidemia is an inherited metabolic disease caused by a deficiency in the propionyl-CoA carboxilase, a biotin-dependent mitochondrial enzyme. The disorder is a clinically heterogeneous disease and one of the most frequently occurring organic acidurias. We report the first Cuban case with a severe form of propionic acidemia followed by acidosis and death. The diagnosis was carried out by gas chromatography coupled to mass spectrometry. Our aim is to highlight the importance of organic acids urine analysis as part of the first laboratory tests in undiagnosed seriously ill children. The definitive diagnosis is important as it serves as a clear guideline to establish a suitable treatment and allows geneticists to provide patients with a proper genetic counseling

  2. Rapid quantification of dimethyl methylphosphonate from activated carbon particles by static headspace gas chromatography mass spectrometry.

    Science.gov (United States)

    Mitchell, Brendan L; Billingsley, Brit G; Logue, Brian A

    2013-06-01

    Activated carbon (AC) particles are utilized as an adsorbent for binding hazardous vapors in protective equipment. The binding affinity and utilization of these AC particles should be known to ensure effective and efficient use. Therefore, a simple and effective method was developed for the quantification of the chemical warfare agent simulant, dimethyl methylphosphonate (DMMP), from AC particles. Static headspace gas chromatography mass-spectrometry with internal standard, DMMP-d6, was used to perform the analysis. The method produced a linear dynamic range of 2.48-620g DMMP/kg carbon and a detection limit of 1.24g DMMP/kg carbon. Furthermore, the method produced a coefficient of variation of less than 16% for all intra- and inter-assay analyses. The method provided a simple and effective procedure for quantifying DMMP from AC particles and was applied to the analysis of a DMMP-exposed AC protective respirator filter.

  3. Carbon monoxide analysis: a comparison of two co-oximeters and headspace gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Costantino, A.G.; Park, J.; Caplan, Y.H.

    Three methods (lL-182 Co-Oximeter, lL-282 Co-Oximeter, and headspace gas chromatography) for the analysis of carbon monoxide in postmortem blood were studied and compared using a prepared reference standard, Quantra control materials, and 62 postmortem blood specimens. The methods compared favorably with one another. The linear regression equations for the 62 postmortem blood samples (range = 1.0 to 86% saturation) were: lL-282 vs. lL-182, y = 1.11x - 3.10, r = 0.981; lL-182 vs. GC, y = 0.88x + 2.97, r = 0.973; lL-282 vs. GC, y = 1.00x - 1.24, r = 0.986.

  4. Rapid determination of moisture content in paper materials by multiple headspace extraction gas chromatography.

    Science.gov (United States)

    Xie, Wei-Qi; Chai, Xin-Sheng

    2016-04-22

    This paper describes a new method for the rapid determination of the moisture content in paper materials. The method is based on multiple headspace extraction gas chromatography (MHE-GC) at a temperature above the boiling point of water, from which an integrated water loss from the tested sample due to evaporation can be measured and from which the moisture content in the sample can be determined. The results show that the new method has a good precision (with the relative standard deviation <0.96%), high sensitivity (the limit of quantitation=0.005%) and good accuracy (the relative differences <1.4%). Therefore, the method is quite suitable for many uses in research and industrial applications. PMID:27033986

  5. Determination of solubility parameters and thermodynamic properties in hydrocarbon-solvent systems by gas chromatography

    Directory of Open Access Journals (Sweden)

    E. Díaz

    2007-06-01

    Full Text Available Gas chromatography used to calculate the specific retention volume of several hydrocarbons in different chromatographic liquid phases (Squalane, Carbowax-400, Carbowax-1500, Carbowax-4000, Amine-220, Dinonyl phthalate, Tributyl phosphate and Trixylenyl phosphate. Some thermodynamic parameters, such as enthalpy of sorption and Flory-Huggins parameters relating the interaction between liquid phases and solutes, were also calculated from the determined retention volumes. Liquid phase solubility parameters of Squalane, Carbowax-400, Carbowax-1500 and Carbowax-4000 at 80 ºC as well as the polar and apolar components were calculated too. A new model was proposed to correlate polar contribution to the solubility parameter of a liquid phase with the specific retention volume of a solute in this liquid phase.

  6. The Application of Resonance-Enhanced Multiphoton Ionization Technique in Gas Chromatography Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Adan Li

    2014-01-01

    Full Text Available Gas chromatography resonance-enhanced multiphoton ionization time-of-flight mass spectrometry (GC/REMPI-TOFMS using a nanosecond laser has been applied to analyze the 16 polycyclic aromatic hydrocarbons (PAHs. The excited-state lifetime, absorption characters, and energy of electronic states of the 16 PAHs were investigated to optimize the ionization yield. A river water sample pretreated by means of solid phase extraction was analyzed to evaluate the performance of the analytical instrument. The results suggested that REMPI is superior to electron impact ionization method for soft ionization and suppresses the background signal due to aliphatic hydrocarbons. Thus, GC/REMPI-TOFMS is a more reliable method for the determination of PAHs present in the environment.

  7. Determining the relative age of blue ballpoint ink by gas chromatography

    Institute of Scientific and Technical Information of China (English)

    Yao Lijuan; Zhao Pengcheng; Wang Jinghan; Wang Yanji

    2006-01-01

    A method for identifying the writing age of blue ballpoint pen ink has been established due to the imperative demand in forensic laboratories.The content of the volatile components in blue ballpoint pen ink were determined by gas chromatography(GC).The absorbance of dye in blue ballpoint pen ink was measured by UV-Vis spectrometry A writing age curve of the ink was established using the ratio of the content of the volatile components to the dye,based on the identification of 74 kinds of blue ballpoint pen ink of domestic and international origins.The change of benzene alcohol or phenoxetol with the writing age was also tested.Different kinds of blue ballpoint pen ink were detected and the repeatability of the experiment was investigated.The results indicate that the method is reliable,sensitive,systematic and is especially suitable for practical use.

  8. H2S Analysis in Biological Samples Using Gas Chromatography with Sulfur Chemiluminescence Detection

    Science.gov (United States)

    Vitvitsky, Victor; Banerjee, Ruma

    2015-01-01

    Hydrogen sulfide (H2S) is a metabolite and signaling molecule in biological tissues that regulates many physiological processes. Reliable and sensitive methods for H2S analysis are necessary for a better understanding of H2S biology and for the pharmacological modulation of H2S levels in vivo. In this chapter, we describe the use of gas chromatography coupled to sulfur chemiluminescence detection to measure the rates of H2S production and degradation by tissue homogenates at physiologically relevant concentrations of substrates. This method allows separation of H2S from other sulfur compounds and provides sensitivity of detection to ~15 pg (or 0.5 pmol) of H2S per injected sample. PMID:25725519

  9. Determination of constituents of essential oil from Angelica sinensis by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    WU Ming-jian; SUN Xian-jun; DAI Yuan-hui; GUO Fang-qiu; HUANG Lan-fang; LIANG Yi-zeng

    2005-01-01

    Gas chromatography-mass spectrometry (GC-MS) coupled with chemometric resolution upon two-dimensional data was employed to analyze the constituents of essential oils of Angelica sinensis. Constituents in essential oils of Angelica sinensis root were identified by GC-MS with the help of subwindow factor analysis (SFA) method resolving two-dimensional original data into mass spectra and chromatograms. 76 of 97 separated constituents in essential oil of Angelica sinensis root were identified and quantified, and they account for about 91.36% of the total content. The results show that ligustilide, butylene phthalide, 2-methoxy-4-vinylphenol, carvacrol, allo-ocimene,2,6,6-trimethylbicyclo-[3,1,1]hept-2-ene are the main constituents in essential oil of Angelica sinensis root.

  10. Quantitative Analysis and Fingerprint Profiles for Quality Control of Fructus Schisandrae by Gas Chromatography: Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Yong-Gang Xia

    2014-01-01

    Full Text Available This paper describes a simple, rapid, and effective quality assessment method for Fructus Schisandrae by gas chromatography-mass spectrum (GC-MS. The method was established by using specific lignan fingerprint profiles and quantitation of characteristic compounds in this herbal medicine. The GC-MS fingerprints of 15 batches of Schisandra samples from different regions of China showed similar lignan profiles. Five peaks were selected as characteristic peaks, and all of these were identified by using GC-MS techniques. The relative retention times of these characteristic peaks in the GC-MS fingerprint were established as an important parameter for identification of Schisandra samples. Meanwhile, relative peak areas may be a feasible approach to discriminate the S. chinensis and S. sphenanthera. Finally, these pharmacologically active constituents in the titled plant, schisandrins A–C and schizandrols A and B, were quantitatively determined using a validated GC-MS method.

  11. Effects of the sniffing port air makeup in gas chromatography-olfactometry.

    Science.gov (United States)

    Hanaoka, K; Sieffermann, J M; Giampaoli, P

    2000-06-01

    A time-intensity gas chromatography-olfactometry (GCO) apparatus was developed to study some aerodynamic parameters that may influence odor detection and intensity measurements by the subjects. The addition of humidified air at the elution place of the compounds is generally recommended for several reasons (essentially to prevent nasal mucosa dehydration and to improve chromatographic effluent carriage out of the column), but clues about these effects are yet to be published. This question is studied through two complementary experiments using synthetic solutions of 3-methyl-1-butanethiol, hexan-2-one, octanal, nonanal, furfural, citronellal, benzaldehyde, octan-1-ol, 2-phenylethyl acetate, guaiacol, 2-phenylethanol, and vanillin. This work demonstrates the need for an air makeup to increase odor detection frequency and intensity rating. With the conditions tested, a minimum makeup air flow rate of 50 L.min(-)(1) is necessary. On the contrary, humidification of the makeup is useless for the sniffers comfort and to improve the quantitative GCO results.

  12. Rapid measurement of phytosterols in fortified food using gas chromatography with flame ionization detection.

    Science.gov (United States)

    Duong, Samantha; Strobel, Norbert; Buddhadasa, Saman; Stockham, Katherine; Auldist, Martin; Wales, Bill; Orbell, John; Cran, Marlene

    2016-11-15

    A novel method for the measurement of total phytosterols in fortified food was developed and tested using gas chromatography with flame ionization detection. Unlike existing methods, this technique is capable of simultaneously extracting sterols during saponification thus significantly reducing extraction time and cost. The rapid method is suitable for sterol determination in a range of complex fortified foods including milk, cheese, fat spreads, oils and meat. The main enhancements of this new method include accuracy and precision, robustness, cost effectiveness and labour/time efficiencies. To achieve these advantages, quantification and the critical aspects of saponification were investigated and optimised. The final method demonstrated spiked recoveries in multiple matrices at 85-110% with a relative standard deviation of 1.9% and measurement uncertainty value of 10%. PMID:27283669

  13. Accurate determination of fiber water-retaining capability at process conditions by headspace gas chromatography.

    Science.gov (United States)

    Zhang, Shu-Xin; Chai, Xin-Sheng; He, Liang

    2016-09-16

    This work reports on a method for the accurate determination of fiber water-retaining capability at process conditions by headspace gas chromatography (HS-GC) method. The method was based the HS-GC measurement of water vapor on a set closed vials containing in a given amount pulp with different amounts of water addition, from under-saturation to over-saturation. By plotting the equilibrated water vapor signal vs. the amount of water added in pulp, two different trend lines can be observed, in which the transition of the lines corresponds to fiber water-retaining capability. The results showed that the HS-GC method has good measurement precision (much better than the reference method) and good accuracy. The present method can be also used for determining pulp fiber water-retaining capability at the process temperatures in both laboratory research and mill applications. PMID:27554029

  14. Gas Chromatography/Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometry for Fingerprinting the Macondo Oil Spill.

    Science.gov (United States)

    Lobodin, Vladislav V; Maksimova, Ekaterina V; Rodgers, Ryan P

    2016-07-01

    We report the first application of a new mass spectrometry technique (gas chromatography combined to atmospheric pressure chemical ionization tandem mass spectrometry, GC/APCI-MS/MS) for fingerprinting a crude oil and environmental samples from the largest accidental marine oil spill in history (the Macondo oil spill, the Gulf of Mexico, 2010). The fingerprinting of the oil spill is based on a trace analysis of petroleum biomarkers (steranes, diasteranes, and pentacyclic triterpanes) naturally occurring in crude oil. GC/APCI enables soft ionization of petroleum compounds that form abundant molecular ions without (or little) fragmentation. The ability to operate the instrument simultaneously in several tandem mass spectrometry (MS/MS) modes (e.g., full scan, product ion scan, reaction monitoring) significantly improves structural information content and sensitivity of analysis. For fingerprinting the oil spill, we constructed diagrams and conducted correlation studies that measure the similarity between environmental samples and enable us to differentiate the Macondo oil spill from other sources.

  15. Direct Determination of the Blood Concentration of Halogenated Anesthetic Agents by Gas Chromatography

    Directory of Open Access Journals (Sweden)

    Yamada,Teruo

    1988-08-01

    Full Text Available The direct determination by gas chromatography of blood levels of anesthetic agents has been difficult because of the water content of blood. In the present study, the method of Yokota et al. (1967 was modified by improving the packing materials of the column, the blood sample vaporizer and the flow-path during analysis. As a result, accurate and reproducible determination of halothane, enflurane and isoflurane dissolved in blood was achieved. With this system, blood in which halothane, enflurane and isoflurane had been dissolved could be analyzed without changing the column between samples. Moreover, each sample was prepared in less than 10 min, and more than 100 consecutive determinations could be made with excellent reproducibility. The coefficient of variation was less than 3.8%.

  16. Gas chromatography-mass spectrometry analysis of various organic extracts ofMerremia borneensisfrom Sabah

    Institute of Scientific and Technical Information of China (English)

    M Amzad Hossain; Muhammad Dawood Shah; Mahyar Sakari

    2011-01-01

    Objective:To analyse the chemical composition of different extracts ofMerremia borneensis (M. borneensis) by gas chromatography-mass spectrometry (GC-MS).Methods: The dried leaves powder was extracted with methanol at room temperature by using Soxhlet extractor. Methanol crude extracts ofM. borneensis were extrastel with hexane, chloroform, ethyl acetate and butanol. Results: Qualitative analyses of various organic crude extracts showed that majority of these are flavonoids, terpeniods, alkaloids and glycosides. Most of the identified compounds by GC-MS are biologically important. Further theM. borneensisleaf possesses certain characteristics that can be ascribed to cultivation on a domestic plantation.Conclusions: The suitable extracts for respective compounds can be chosen on the basis of aboveGC-MS analysis. All the major compounds from different extracts are biologically active molecules. Thus the identification of a good number of compounds from various extractsM. borneensis might have some ecological significance.

  17. Rapid measurement of phytosterols in fortified food using gas chromatography with flame ionization detection.

    Science.gov (United States)

    Duong, Samantha; Strobel, Norbert; Buddhadasa, Saman; Stockham, Katherine; Auldist, Martin; Wales, Bill; Orbell, John; Cran, Marlene

    2016-11-15

    A novel method for the measurement of total phytosterols in fortified food was developed and tested using gas chromatography with flame ionization detection. Unlike existing methods, this technique is capable of simultaneously extracting sterols during saponification thus significantly reducing extraction time and cost. The rapid method is suitable for sterol determination in a range of complex fortified foods including milk, cheese, fat spreads, oils and meat. The main enhancements of this new method include accuracy and precision, robustness, cost effectiveness and labour/time efficiencies. To achieve these advantages, quantification and the critical aspects of saponification were investigated and optimised. The final method demonstrated spiked recoveries in multiple matrices at 85-110% with a relative standard deviation of 1.9% and measurement uncertainty value of 10%.

  18. Discrimination of honeys using colorimetric sensor arrays, sensory analysis and gas chromatography techniques.

    Science.gov (United States)

    Tahir, Haroon Elrasheid; Xiaobo, Zou; Xiaowei, Huang; Jiyong, Shi; Mariod, Abdalbasit Adam

    2016-09-01

    Aroma profiles of six honey varieties of different botanical origins were investigated using colorimetric sensor array, gas chromatography-mass spectrometry (GC-MS) and descriptive sensory analysis. Fifty-eight aroma compounds were identified, including 2 norisoprenoids, 5 hydrocarbons, 4 terpenes, 6 phenols, 7 ketones, 9 acids, 12 aldehydes and 13 alcohols. Twenty abundant or active compounds were chosen as key compounds to characterize honey aroma. Discrimination of the honeys was subsequently implemented using multivariate analysis, including hierarchical clustering analysis (HCA) and principal component analysis (PCA). Honeys of the same botanical origin were grouped together in the PCA score plot and HCA dendrogram. SPME-GC/MS and colorimetric sensor array were able to discriminate the honeys effectively with the advantages of being rapid, simple and low-cost. Moreover, partial least squares regression (PLSR) was applied to indicate the relationship between sensory descriptors and aroma compounds. PMID:27041295

  19. Application of Pyrolysis Gas Chromatography/Mass Spectrometry in Lacquer Research: A Review

    Directory of Open Access Journals (Sweden)

    Xiao-Ming Ma

    2014-01-01

    Full Text Available Examination of thermal degradation of natural and synthetic lacquer films by pyrolysis-gas chromatography with mass spectrometry (Py-GC/MS is reviewed. Due to the instantaneous heating decomposition, side reactions of internal or intermediate samples hardly occur, and the pyrolysis products can be retrieved without any change. Py-GC/MS has been used to analyze the composition of insoluble polymers and investigate degradation of resin materials. Lacquer film is a cross-linked polymer that is insoluble in any solvent. The aim of this review is to describe the application of Py-GC/MS to the analysis of lacquer, including natural lacquer saps, synthetic lacquer derivatives, and their films. After analyzing the chemical structures of the specific pyrolysis products by mass spectrometry, the lacquer tree species and growing region can be determined. These results have great significance for the protection and restoration of lacquer-coated cultural treasures.

  20. Gas chromatography/mass spectrometry for the determination of nitrosamines in red wine.

    Science.gov (United States)

    Lona-Ramirez, Fernando J; Gonzalez-Alatorre, Guillermo; Rico-Ramírez, Vicente; Perez-Perez, Ma Cristina I; Castrejón-González, Edgar O

    2016-04-01

    N-nitrosamines (NAms) are highly active carcinogens that have been detected in food and beverages. Currently certain studies report their presence in red wine, while others fail to detect their presence. In this study the head space solid phase micro-extraction technique coupled to gas chromatography-mass spectrometry (HS-SPME-GC-MS) was applied to quantify four NAms in different types of red wine. The technique was found to be a simple, precise, fast and environmentally friendly alternative for the quantification of volatile NAms. A factorial analysis was carried out to evaluate the influence of the parameters on the HS-SPME technique. This is the first study that such analysis has been reported and where NAms in red wine have been quantified using HS-SPME-GC-MS. The method was validated by calculating the linearity, limit of detection and quantification. Two of the four NAms analyzed were found to be present in red wine samples.

  1. Gas chromatography of safranal as preferable method for the commercial grading of saffron (Crocus sativus L.).

    Science.gov (United States)

    Bononi, Monica; Milella, Paola; Tateo, Fernando

    2015-06-01

    We present a new extraction protocol, using ethyl alcohol as a solvent, to evaluate safranal by gas chromatography (GC). A linear response was obtained with R(2)=0.995 and a reproducibility standard deviation of 4.7-6.0%. The limit of detection and limit of quantitation were 0.05 and 0.25gkg(-1), respectively. The GC data for several samples of powdered saffron from different origins were compared to specific absorbance values measured according to the ISO Normative 3632-1:2011 method. The aroma strength of saffron samples quantitated by GC and the specific absorbance values of safranal by the UV method did not correlate. Quantitative evaluation of safranal by GC appears to be more specific and useful for commercial comparisons of saffron quality.

  2. Determination of microquantities of methanol and ethanol in toluene by gas chromatography

    International Nuclear Information System (INIS)

    A study is made of the detection of methanol and ethanol in toluene by means of gas chromatography, using Porapak Q columns, 1 m long at 189 degree centigree, employing a flame ionization detector, with propanol as an internal standard. The variation od the detector absolute and relative response was found to be linear within the range of concentration studied, that is, from 5 to 1000 ppm. The limit of sensitivity for the detection of ethanol in a column of 2% Ucon, over Chromosorob G deactivated with 0,1% Carbowax 400, was 20 ppm, which was four times higher than the limit of sensitivity of the Porapak Q column. Also in this case, the absolute and relative response of the detector was linear. (Author) 3 refs

  3. Rapid determination of moisture content in paper materials by multiple headspace extraction gas chromatography.

    Science.gov (United States)

    Xie, Wei-Qi; Chai, Xin-Sheng

    2016-04-22

    This paper describes a new method for the rapid determination of the moisture content in paper materials. The method is based on multiple headspace extraction gas chromatography (MHE-GC) at a temperature above the boiling point of water, from which an integrated water loss from the tested sample due to evaporation can be measured and from which the moisture content in the sample can be determined. The results show that the new method has a good precision (with the relative standard deviation <0.96%), high sensitivity (the limit of quantitation=0.005%) and good accuracy (the relative differences <1.4%). Therefore, the method is quite suitable for many uses in research and industrial applications.

  4. Analysis of 5-hydroxymethylfurfural in foods by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Teixidó, E; Santos, F J; Puignou, L; Galceran, M T

    2006-11-24

    A new, simple and selective method for the analysis of 5-hydroxymethylfurfural (HMF) in foods by gas chromatography coupled to mass spectrometry (GC-MS) is proposed. Several derivatising procedures based on the formation of an HMF silylated derivative using different reagents were studied. Among the derivatising reagents examined, N,O-bis-trimethylsilyltrifluoroacetamide (BSTFA) provided the best derivatisation yield. Sample clean-up was also optimised, using either liquid-liquid extraction with dichloromethane or solid-phase extraction (SPE) with several commercially available cartridges, and the best results were obtained using ENV+ cartridges. Quality parameters such as day-to-day and run-to-run precision (RSD<10%), linearity (between 25 and 700 ng g(-1)) and detection limit (6 ng g(-1)) were established. This method was successfully applied to the analysis of HMF content in several Spanish food samples from a local market, such as jam, honey, orange juice and bakery products. PMID:17010355

  5. A micro gas chromatography column with a micro thermal conductivity detector for volatile organic compound analysis

    Science.gov (United States)

    Sun, J. H.; Cui, D. F.; Chen, X.; Zhang, L. L.; Cai, H. Y.; Li, H.

    2013-02-01

    In this paper, a micro gas chromatography (μGC) system contained a μGC column and a micro thermal conductivity detector (μTCD) was proposed. In order to reduce the volume of the system, some micro heaters were integrated on the surface and backside of the GC column, which could provide a robust temperature programming capability and rapidly increase the temperature of the μGC column. In addition, a silicon-glass μTCD with four-thermistor thermal conductivity cells that can offer significant advantages over previously reported designs including low dead volume, good thermal isolation, and elimination of the thermal noise was proposed in this paper. Experimental results have indicated that the μGC system with a detection limit of several ppm concentration levels separated and detected the benzene, toluene, and styrene in less than 3 min, and the μGC system also exhibited a good linear response in the test range.

  6. The determination of 5-fluorouracil in human plasma by a gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    A gas chromatography-mass spectrometry method for the determination of 5-fluorouracil in human plasma is described. The method involves a single extraction procedure with 10 ml of isopropanol-eth-er(20:80) solution and pentafluoro-benzylation. Samples were injected using an automatic injector, followed by separation on a nonpolar capillary column and detection with a mass selective detector(MSD). No en-dogeneous compounds were found to interfere. The detection limit, based upon an assayed plasma volume of 0.5, was 3 ng/ml. The extraction yield was found to be above 80%. Plasma 5-FU concentrations were det-ermined by this method in about 500 plasma samples from cancer patients undergoing treatment with 5-FU. This method is suitable for monitoring of 5-FU in plasma of cancer patients

  7. A study of the thermal activation of synthetic zeolites (molecular sieve) for gas-solid chromatography

    International Nuclear Information System (INIS)

    The thermal activation of synthetic zeolites from two sources has been investigated with reference to the adsorption chromatography of inorganic gases. It was found that the heats of adsorption for oxygen and carbon monoxide increased with activation temperature. Limits of detection for oxygen in argon and conversely argon in oxygen were determined as well as the chromatographic stability of the activated zeolite. The practical implications and importance of the results are discussed and the application to the analysis of fast reactor blanket gas is mentioned. An explanation is proposed for the adsorption behaviour of these activated materials, based on an electrostatic mechanism, and this has suggested a reason for the separation characteristics of oxygen and argon on polar zeolites. Further work is identified including the investigation of energy states of the oxygen molecule adsorbed on activated zeolite by means of ultra-violet photoelectron spectroscopy. (author)

  8. Characterization of volatile organic compounds by thermal desorption/gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Carbonaceous triple sorbent traps (TSTs) have been widely used to collect and concentrate volatile organic compounds (VOCs) in vapor phase samples for subsequent GC/MS analysis. Recently, this laboratory has been involved in sampling and analyzing VOCs collected from various emission sources, including headspace samples from underground storage tanks at the Department of Energy's Hanford site, in Richland, Washington. In order to evaluate the sampling adequacy and to assess any health-related impact based on the analysis results, a validated method must be employed. Therefore, the main objective of this study was to develop a methology for thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS) determination of VOCs in the vapor phase samples collected on Carbotrap C/Carbotrap/Carbosieve S III triple sorbent traps. Techniques used in method validation included VOC standard generation, thermal desorption efficiency, reproducibility of spiking on and recovery from TST, use of internal standards, detection limits determination, linearity and reproducibility of calibration

  9. Novel guanidinium-based ionic liquids as stationary phases for capillary gas chromatography

    Institute of Scientific and Technical Information of China (English)

    Li Zhen Qiao; Kai Lu; Mei Ling Qi; Ruo Nong Fu

    2010-01-01

    The present study describes guanidinium-based ionic liquids(GBILs)as stationary phases for capillary gas chromatography(CGC)and to the best of our knowledge,no related reports are available up to now.In this study,a hexaalkylguanidinium ionic liquid(DOTMG-NTf2)was synthesized and coated statically onto capillary columns.Selectivity of the stationary phase was evaluated by separating Grob test mixture,test mixture,alcohols mixture,and fatty acid methyl esters mixture,and thermal stability was investigated as well.The present study demonstrates that GBILs as CGC stationary phases exhibit satisfactory selectivity and thermal stability and have a great potential as new candidates for CGC stationary phases.

  10. PDMS Rod-SBSE System Coupled with Gas Chromatography for Determination of PAHs in Aqueous Samples

    Institute of Scientific and Technical Information of China (English)

    CHENG Chuan-xian; PEI Hai-rong; LAN Xiao-zheng

    2011-01-01

    A method for the analysis of trace polycyclic aromatic hydrocarbons(PAHs) in aqueous samples has been established by polydimethylsiloxane(PDMS) rod aided stir bar sorptive extraction(SBSE).The homemade PDMS rod has a size of 30 mm×3 mm o.d.with a volume of ca.200 μL,stable in thermal desorption process.The enriched PAHs by the PDMS rod were released in a homemade thermal desorption system coupled with gas chromatography.Experimental parameters for extraction of six PAHs were optimized including extraction time,pH,ionic strength and temperature of solution.The procedure has good recoveries of 80.0%-100.3% and very low limits of detection of 4.0-33 ng/L.PAHs in rain and river water were analyzed by this method.

  11. Thermal and Hydrothermal Treatment of Silica Gels as Solid Stationary Phases in Gas Chromatography

    Directory of Open Access Journals (Sweden)

    Ashraf Yehia El-Naggar

    2013-01-01

    Full Text Available Silica gel was prepared and treated thermally and hydrothermally and was characterized as solid stationary phase in gas chromatography. The characteristics have been evaluated in terms of polarity, selectivity, and separation efficiencies. These parameters were used to assess the outer silica surface contributions and the degree of surface deactivation brought about by different treatment techniques. The parent silica elutes the paraffinic hydrocarbons with high efficiency of separation and elutes aromatic hydrocarbons with nearly good separation and has bad separation of alcohols. The calcined silica at 500°C and 1000°C has a pronounced effect on the separation of aromatic hydrocarbons compared with the parent silica and hydrothermal treatment of silica. With respect to alcohols separation, the obtained bad separations using treated and untreated silica reflect the little effect of the thermal and hydrothermal treatment on the silica surface deactivation.

  12. Multiresidue analysis of 30 organochlorine pesticides in milk and milk powder by gel permeation chromatography-solid phase extraction-gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zheng, Guocan; Han, Chao; Liu, Yi; Wang, Jing; Zhu, Meiwen; Wang, Chengjun; Shen, Yan

    2014-10-01

    A method for simultaneous determination of the 30 organochlorine pesticides (OCP) in milk and milk powder samples has been developed. Prior to the gas chromatography-tandem mass spectrometric analysis, the residual OCP in samples were extracted with n-hexane and acetone mixture (1/1, vol/vol) and cleaned up by gel permeation chromatography and solid phase extraction. Selected reaction monitoring mode was used for gas chromatography-tandem mass spectrometric data acquisition to identify and quantify the OCP. To avoid the matrix effects, matrix-matched calibration solutions ranging from 2 to 50 ng/mL were used to record the calibration curve. Limits of quantification of all OCP were 0.8 μg/kg. With the exception of endrin, limits of quantification are significantly lower than maximum residue limits set by the European Union and China. The average recoveries were in the range of 70.1 to 114.7% at 3 spiked concentration levels (0.8, 2.0, and 10.0 μg/kg) with residual standard deviation lower than 12.9%. The developed method was successfully applied to analyze the OCP in commercial milk products. PMID:25087035

  13. One-step multiple component isolation from the oil of Crinitaria tatarica (Less) Sojak by preparative capillary gas chromatography with characterization by spectroscopic and spectrometric techniques

    Science.gov (United States)

    In the present work multiple component isolation from the oil of Crinitaria tatarica (Less.) Sojak. by Preparative Capillary Gas Chromatography (PCGC) with characterization by mass spectrometry (MS) and nuclear magnetic resonance (NMR) spectroscopy have been carried out. Gas chromatography (GC-FID) ...

  14. Determination of Beeswax Hydrocarbons by Gas Chromatography with a Mass Detector (GC -MS Technique

    Directory of Open Access Journals (Sweden)

    Waś Ewa

    2014-06-01

    Full Text Available Here we describe a method of hydrocarbon (alkanes, alkenes, dienes identification and quantitative determination of linear saturated hydrocarbons (n-alkanes in beeswax using gas chromatography with a mass detector technique (GC -MS . Beeswax hydrocarbons were isolated using a solid-phase extraction (SPE technique with neutral aluminum oxide (Alumina - N, 1000 mg, 6 mL, then were separated on a non-polar gas chromatography column ZB-5HT INFERNO (20 m×0.18 mm×0.18 μm. Qquantitative analysis of n-alkanes was conducted by the method of internal standard with squalane used as the internal standard. The basic parameters of validation (linearity and working range, limit of determination, repeatability and reproducibility, recovery were determined. For all of the identified compounds, satisfactory (≥0.997 coefficients of correlation in the working ranges of the method (from 0.005 to 5.0 g/100 g were obtained. The elaborated method was characterized by satisfactory repeatability and within-laboratory reproducibility. The average coefficients of variation for the total n-alkanes did not exceed 2% under conditions of repeatability or 4% under conditions of reproducibility. The recovery for individual n-alkanes was above 94%; for their total content, it was 100.5%. In beeswax originating from Apis mellifera, n-alkanes containing from 20 to 35 carbon atoms in their molecules were determined. The total content of these alkanes was between 9.08 g and 10.86 g/100 g (on average, 9.81 g/100 g. Additionally, apart from the saturated hydrocarbons, unsaturated hydrocarbons and dienes were identified.

  15. Analysis of phenolic acids as chloroformate derivatives using solid phase microextraction-gas chromatography.

    Science.gov (United States)

    Citová, Ivana; Sladkovský, Radek; Solich, Petr

    2006-07-28

    In the presented study, a simple and original procedure of phenolic acids derivatization treated by ethyl and methyl chloroformate performed in an aqueous media consisting of acetonitrile, water, methanol/ethanol and pyridine has been modified and optimized. Seven phenolic acid standards-caffeic, ferulic, gallic, p-coumaric, protocatechuic, syringic and vanillic were derivatized into corresponding methyl/ethyl esters and subsequently determined by the means of gas chromatography connected to the flame-ionisation detector (FID). Some selected validation parameters as linearity, detection and quantitation limits and peak area repeatability were valued. The total time of gas chromatography (GC) analysis was 24 min for methyl chloroformate and 30 min for ethyl chloroformate derivatization. The more suitable methyl chloroformate derivatization was used for further experiments on the possibility of multiple pre-concentration by the direct solid phase microextraction technique (SPME). For this purpose, polyacrylate (PA), polydimethylsiloxane (PDMS), carboxen/polydimethylsiloxane (CAR/PDMS) and polydimethylsiloxane/divinylbenzene (PDMS/DVB) fibres were tested and the extraction conditions concerning time of extraction, temperature and time of desorption were optimized. The most polar PA fibre gave the best results under optimal extraction conditions (50 min extraction time, 25 degrees C extraction temperature and 10 min desorption time). As a result, the total time of SPME-GC analysis was 74 min and an increase in method sensitivity was reached. The limits of quantitation (LOQ) of p-coumaric, ferulic, syringic and vanillic acid esters after SPME pre-concentration were 0.02, 0.17, 0.2 and 0.2 microg mL(-1), respectively, showing approximately 10 times higher sensitivity in comparison with the original GC method. PMID:17723529

  16. Detection of Tocopherol in Oilseed Rape (Brassica napus L.) Using Gas Chromatography with Flame Ionization Detector

    Institute of Scientific and Technical Information of China (English)

    Nazim Hussain; Zahra Jabeen; LI Yuan-long; CHEN Ming-xun; LI Zhi-lan; GUO Wan-li; Imran Haider Shamsi; CHEN Xiao-yang; JIANG Li-xi

    2013-01-01

    The variation among Chinese genotypes of Brassica napus L. for seed tocopherols content and their analysis using gas chromatography has not been comprehensively reported till to date. In the present study, the tocopherol contents of four Chinese genotypes of Brassica napus L., namely, Gaoyou 605, Zhejiang 619, Zheshuang 758, and Zheshuang 72, were evaluated using three modified sample preparation protocols (P1, P2, and P3) for tocopherol extraction. These methods were distinguished as follows. Protocol one (P1) included the evaporation of solvent after extraction without silylation. Protocol two (P2) followed the direct supernatant collection after overnight extraction without drying and silylation. Protocol three (P3) included trimethylsilylation with N,O-bis(trimethylsilyl) trifluoroacetamide. Genotypic comparison of tocopherol and its isoforms revealed that Gaoyou 605 was dominant over the other genotypes with (140.5±10.5), (316.2± 9.2), and (559.1± 24.3)μg g-1 of seed mealα-,γ-, and total (T-) tocopherol, respectively, and a 0.44±0.04α-toγ-tocopherol ratio. The comparison of the sample preparation protocols, on the other hand, suggests that P3 is the most suitable method for the tocopherol extraction from Brassica oilseeds and for the analysis of tocopherols using gas chromatography flame ionization detector (GC-FID). Trimethylsilylation is the key step differentiating P3 from P1 and P2. Variations detected in tocopherol contents among the Chinese rapeseed (B. napus) genotypes signify the need to quantify a wide range of rapeseed germplasm for seed tocopherol dynamics in short and crop improvement in long.

  17. Analysis of pesticides by gas chromatography/multiphoton ionization/mass spectrometry using a femtosecond laser

    International Nuclear Information System (INIS)

    Highlights: → Gas chromatography/multiphoton ionization/time-of-flight mass spectrometry was utilized for analysis. → A standard mixture sample containing 49 pesticides and 4 real samples were measured. → Third-harmonic emission of a Ti:sapphire laser (100 fs) was employed as an ionization source. → Most of the pesticides were softly ionized by the femtosecond laser. → Three pesticides were found, although some of them were not detected by GC/EI/MS-MS. - Abstract: Gas chromatography/multiphoton ionization/time-of-flight mass spectrometry (GC/MPI/TOFMS) was utilized for analysis of a standard mixture sample containing 49 pesticides and 4 real samples using the third-harmonic emission (267 nm) of a femtosecond Ti:sapphire laser (100 fs) as the ionization source. A sample of a standard mixture of n-alkane was also measured for calibration of the retention time indices of the pesticides. Two photons are required for the excitation of n-alkane due to an absorption band located in the far ultraviolet region (140 nm). The n-alkane molecule in the excited state was subsequently ionized either directly or by absorbing another photon because of a high ionization potential. Due to a large excess of energy, the molecular ion was decomposed and formed many fragment ions. Compared to n-alkanes, most of the pesticides were softly ionized by the femtosecond laser; one photon was used for excitation and another was used for the subsequent ionization. The pesticides with no conjugated double bond had a lower ionization efficiency. The present analytical instrument was applied to several samples prepared from a variety of vegetables and a single fruit after pretreatment with solid-phase extraction. Three pesticides were found in these samples, although some of them were not detected by conventional GC/EI/MS-MS due to insufficient sensitivity and selectivity.

  18. Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Douglas C., E-mail: douglas.baxter@alsglobal.com [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Faarinen, Mikko [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Osterlund, Helene; Rodushkin, Ilia [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Division of Geosciences, Lulea University of Technology, 977 87 Lulea (Sweden); Christensen, Morten [ALS Scandinavia AB, Maskinvaegen 2, 183 53 Taeby (Sweden)

    2011-09-09

    Highlights: {center_dot} We determine methylmercury in serum and plasma using isotope dilution calibration. {center_dot} Separation by gas chromatography and detection by inductively coupled plasma mass spectrometry. {center_dot} Data for 50 specimens provides first reference range for methylmercury in serum. {center_dot} Serum samples shown to be stable for 11 months in refrigerator. - Abstract: A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with {sup 198}Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) {mu}g L{sup -1} could be performed with uncertainty amplification factors <2. A limit of quantification of 0.03 {mu}g L{sup -1} was estimated at 10 times the standard deviation of concentrations measured in preparation blanks. Within- and between-run relative standard deviations were <10% at added concentration levels of 0.14 {mu}g L{sup -1}, 0.35 {mu}g L{sup -1} and 2.8 {mu}g L{sup -1}, with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; <0.03-0.19) {mu}g L{sup -1}. This is the first time methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.

  19. Qualitative and Quantitative Analysis of Volatile Components of Zhengtian Pills Using Gas Chromatography Mass Spectrometry and Ultra-High Performance Liquid Chromatography

    Science.gov (United States)

    Liu, Cui-ting; Zhang, Min; Yan, Ping; Liu, Hai-chan; Liu, Xing-yun; Zhan, Ruo-ting

    2016-01-01

    Zhengtian pills (ZTPs) are traditional Chinese medicine (TCM) which have been commonly used to treat headaches. Volatile components of ZTPs extracted by ethyl acetate with an ultrasonic method were analyzed by gas chromatography mass spectrometry (GC-MS). Twenty-two components were identified, accounting for 78.884% of the total components of volatile oil. The three main volatile components including protocatechuic acid, ferulic acid, and ligustilide were simultaneously determined using ultra-high performance liquid chromatography coupled with diode array detection (UHPLC-DAD). Baseline separation was achieved on an XB-C18 column with linear gradient elution of methanol-0.2% acetic acid aqueous solution. The UHPLC-DAD method provided good linearity (R2 ≥ 0.9992), precision (RSD protocatechuic acid, ferulic acid, and ligustilide, in 13 batches of ZTPs, which is suitable for discrimination and quality assessment of ZTPs. PMID:26904360

  20. Analysis of polycyclic aromatic hydrocarbons. I. Determination by gas chromatography with glass and fused solica capillary columns

    International Nuclear Information System (INIS)

    A study of the analysis by gas chromatography of aromatic polycyclic hydrocarbons is presented. The separation has been carried out by glass and fused silice capillary column. The limitations and the advantages of the procedure are discussed in terms of separation efficiency, sensitivity and precision. (author). 3 figs., 17 refs

  1. Analysis of polycyclic aromatic hydrocarbons I. Determination by gas chromatography with glass and fused silica capillary columns

    International Nuclear Information System (INIS)

    A study of the analysis by gas chromatography of aromatic polycyclic hydrocarbons is presented. The separation has been carried out by glass and fused silica capillary column. The limitations and the advantages of the procedure are discussed in terms of separation efficiency, sensitivity and precision. (Author) 17 refs

  2. ANALYSIS OF TRACE-LEVEL ORGANIC COMBUSTION PROCESS EMISSIONS USING NOVEL MULTIDIMENSIONAL GAS CHROMATOGRAPHY-MASS SPECTROMETRY PROCEDURES

    Science.gov (United States)

    The paper discusses the analysis of trace-level organic combustion process emissions using novel multidimensional gas chromatography-mass spectrometry (MDGC-MS) procedures. It outlines the application of the technique through the analyses of various incinerator effluent and produ...

  3. Molecular analysis of intact preen waxes of Calidris canutus (Aves : Scolopacidae) by gas chromatography/mass spectrometry

    NARCIS (Netherlands)

    Dekker, MHA; Piersma, T; Damste, JSS; Dekker, Marlèn H.A.; Sinninghe Damsté, Jaap S.

    2000-01-01

    The intact preen wax esters of the red knot Calidris canutus were studied with gas chromatography/mass spectrometry (GC/MS) and GC/MS/MS. In this latter technique, transitions from the molecular ion to fragment ions representing the fatty acid moiety of the wax esters were measured, providing additi

  4. Advantages of Atmospheric Pressure Chemical Ionization in Gas Chromatography Tandem Mass Spectrometry: Pyrethroid Insecticides as a Case Study

    NARCIS (Netherlands)

    Portolés, T.; Mol, J.G.J.; Sancho, J.V.; Hernández, F.

    2012-01-01

    Gas chromatography coupled to mass spectrometry (GC/MS) has been extensively applied for determination of volatile, nonpolar, compounds in many applied fields like food safety, environment, or toxicology. The wide majority of methods reported use electron ionization (EI), which may result in extensi

  5. Introducing Students to Gas Chromatography-Mass Spectrometry Analysis and Determination of Kerosene Components in a Complex Mixture

    Science.gov (United States)

    Pacot, Giselle Mae M.; Lee, Lyn May; Chin, Sung-Tong; Marriott, Philip J.

    2016-01-01

    Gas chromatography-mass spectrometry (GC-MS) and GC-tandem MS (GC-MS/MS) are useful in many separation and characterization procedures. GC-MS is now a common tool in industry and research, and increasingly, GC-MS/MS is applied to the measurement of trace components in complex mixtures. This report describes an upper-level undergraduate experiment…

  6. The Use of Gas Chromatography and Mass Spectrometry to Introduce General Chemistry Students to Percent Mass and Atomic Mass Calculations

    Science.gov (United States)

    Pfennig, Brian W.; Schaefer, Amy K.

    2011-01-01

    A general chemistry laboratory experiment is described that introduces students to instrumental analysis using gas chromatography-mass spectrometry (GC-MS), while simultaneously reinforcing the concepts of mass percent and the calculation of atomic mass. Working in small groups, students use the GC to separate and quantify the percent composition…

  7. Comparison of Genetic Parameters Estimation of Fatty Acids from Gas Chromatography and FT-IR in Holsteins

    DEFF Research Database (Denmark)

    Poulsen, Nina Aagaard; Eskildsen, C E A; Skov, Thomas;

    on fatty acids data measured from gas chromatography in 371 Danish Holstein cows. Results showed similar heritability estimates and strong genomic correlations for most of the fatty acids. However, for some fatty acids, the choice of data affected the genetic parameter estimation, which may be due to...

  8. THE DETERMINATION OF DELTA-5-ANDROSTENEDIOL AND ITS SULFATE IN SERUM AND URINE BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY

    NARCIS (Netherlands)

    DIKKESCHEI, LD; WOLTHERS, BG; WILLEMSE, PHB; VANDERPOL, H; DERUYTERBUITENHUIS, AW; NAGEL, GT

    1993-01-01

    OBJECTIVES We developed an assay for delta-5-androstenediol (adiol) and delta-5-androstenediol-3-sulphate (adiol-3S) in serum and adiol and total adiol sulphate (adiol-S) in urine. DESIGN An analytical procedure using HPLC and gas chromatography-mass spectrometry was devised and tested for its relia

  9. ANALYSIS OF ARTEMISININ AND RELATED SESQUITERPENOIDS FROM ARTEMISIA-ANNUA L BY COMBINED GAS-CHROMATOGRAPHY MASS-SPECTROMETRY

    NARCIS (Netherlands)

    WOERDENBAG, HJ; PRAS, N; BOS, R; VISSER, JF; HENDRIKS, H; MALINGRE, TM

    1991-01-01

    The sesquiterpenoid artemisinin (3) and its biosynthetic precursors arteannuic acid (1), arteannuin B (2) and artemisitene (4) can be separated and identified by combined gas chromatography/mass spectrometry both as a mixture of reference standards as well as in extracts of Artemisia annua L. From t

  10. Direct detection of Mycobacterium tuberculosis in sputum using combined solid phase extraction-gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    N.A. Dang; M. Mourão; S. Kuijper; E. Walters; H.-G. Janssen; A.H.J. Kolk

    2015-01-01

    Recently, thermally-assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) in combination with chemometrics has been used to develop a 20-compound model for fast differentiation of Mycobacterium tuberculosis (MTB) from Non-tuberculous mycobacteria (NTM) in b

  11. Direct analysis of intact glycidyl fatty acid esters in edible oils using gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    H. van Steenbergen; K. Hrnčiřík; A. Ermacora; S. de Koning; H.-G. Janssen

    2013-01-01

    Glycidyl esters (GE), fatty acid esters of glycidol, are process contaminants formed during edible oil processing. A novel direct method for the determination of intact GE in oils and fats based on gas chromatography-mass spectrometry (GC-MS) is presented. The method consists of a simple extraction

  12. Determination of BROMATE AT PARTS-PER-TRILLION LEVELS BY GAS CHROMATOGRAPHY-MASS SPECTROMETRY WITH NEGATIVE CHEMICAL IONIZATION

    Science.gov (United States)

    The ozonation of bromide-containing source waters produces bromate as a class 2B carcinogenic disinfection by-product. The present work describes the determination of bromate by gas chromatography-negative chemical ionization mass spectrometry (GC-NCIMS) following a bromate react...

  13. Detection of Caribbean fruit fly [(Anastrepha suspensa Loew (Diptera: Tephritidae)]-infested grapefruit with portable gas chromatography

    Science.gov (United States)

    New technologies are being sought by plant protection officials to more quickly and efficiently identify concealed pests in imported commodities. The zNose portable gas chromatography unit was investigated as a tool for identifying organic volatile signatures indicative of Caribbean fruit fly infest...

  14. Analyzing Inquiry Questions of High-School Students in a Gas Chromatography Open-Ended Laboratory Experiment

    Science.gov (United States)

    Blonder, Ron; Mamlock-Naaman, Rachel; Hofstein, Avi

    2008-01-01

    This paper describes the implementation of an open-ended inquiry experiment for high-school students, based on gas chromatography (GC). The research focuses on identifying the level of questions that students ask during the GC open inquiry laboratory, and it examines whether implementing the advanced inquiry laboratory opens up new directions for…

  15. An Advanced Analytical Chemistry Experiment Using Gas Chromatography-Mass Spectrometry, MATLAB, and Chemometrics to Predict Biodiesel Blend Percent Composition

    Science.gov (United States)

    Pierce, Karisa M.; Schale, Stephen P.; Le, Trang M.; Larson, Joel C.

    2011-01-01

    We present a laboratory experiment for an advanced analytical chemistry course where we first focus on the chemometric technique partial least-squares (PLS) analysis applied to one-dimensional (1D) total-ion-current gas chromatography-mass spectrometry (GC-TIC) separations of biodiesel blends. Then, we focus on n-way PLS (n-PLS) applied to…

  16. Implementation of Gas Chromatography and Microscale Distillation into the General Chemistry Laboratory Curriculum as Vehicles for Examining Intermolecular Forces

    Science.gov (United States)

    Csizmar, Clifford M.; Force, Dee Ann; Warner, Don L.

    2011-01-01

    As part of an NSF-funded Course Curriculum and Laboratory Improvement (CCLI) project that seeks, in part, to increase student exposure to scientific instrumentation, a gas chromatography experiment has been integrated into the second-semester general chemistry laboratory curriculum. The experiment uses affordable, commercially available equipment…

  17. Analysis of small carbohydrates in several bioactive botanicals by gas chromatography with mass spectrometry and liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Moldoveanu, Serban; Scott, Wayne; Zhu, Jeff

    2015-11-01

    Bioactive botanicals contain natural compounds with specific biological activity, such as antibacterial, antioxidant, immune stimulating, and taste improving. A full characterization of the chemical composition of these botanicals is frequently necessary. A study of small carbohydrates from the plant materials of 18 bioactive botanicals is further described. The study presents the identification of the carbohydrate using a gas chromatographic-mass spectrometric analysis that allows detection of molecules as large as maltotetraose, after changing them into trimethylsilyl derivatives. A number of carbohydrates in the plant (fructose, glucose, mannose, sucrose, maltose, xylose, sorbitol, and myo-, chiro-, and scyllo-inositols) were quantitated using a novel liquid chromatography with tandem mass spectrometric technique. Both techniques involved new method developments. The gas chromatography with mass spectrometric analysis involved derivatization and separation on a Rxi(®)-5Sil MS column with H2 as a carrier gas. The liquid chromatographic separation was obtained using a hydrophilic interaction type column, YMC-PAC Polyamine II. The tandem mass spectrometer used an electrospray ionization source in multiple reaction monitoring positive ion mode with the detection of the adducts of the carbohydrates with Cs(+) ions. The validated quantitative procedure showed excellent precision and accuracy allowing the analysis in a wide range of concentrations of the analytes.

  18. Quantitative determination of G-1 in an emulsifiable concentrate by gas chromatography capillary

    International Nuclear Information System (INIS)

    G-1 is a bioactive obtained from furfural (a sugarcane derivative) which has demonstrated fungicide and bactericide effects on a broad spectrum. In this project a new capillary gas chromatography technique was developed and validated for the quantitative determination of G-1 in an emulsifiable concentrate (used in treatment of an affected skin) with view of future quality control. A capillary column for the separation, nitrogen as the carrier gas (mobile phase) and a flame ionization detector were used. Chromatographic conditions were optimized until high efficiency separation was achieved. Validation was done following the norms described by ICH. G-1 retention time under the created conditions was 4.7 minutes. This technique accomplished the principal validation parameters: linear (in the interval between 0.1 and 0.5 mg/mL), precision [repeatability (variation coefficient= 1.11%)] and intermediate precision (variation coefficient=1.17%), accuracy (covering 100%), sensitivity (the limit of detection is 0.0087mg/mL and the quantification limit is 0.0092mg/mL) and specificity (the width of the half height and symmetry factors did not show significant variations). The technique is hence rendered capable to produce satisfactory results, justifiable by the actual validation parameters.

  19. Determination of Morphine and Codeine in Human Urine by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Xiaoqian Zhang

    2013-01-01

    Full Text Available A sensitive and selective gas chromatography-mass spectrometry (GC-MS method was developed and validated for the determination of morphine and codeine in human urine. The GC-MS conditions were developed. The analysis was carried out on a HP-1MS column (30 m × 0.25 mm, 0.25 μm with temperature programming, and Helium was used as the carrier gas with a flow rate of 1.0 mL/min. Selected ion monitoring (SIM mode was used to quantify morphine and codeine. The derivation solvent, temperature, and time were optimized. A mixed solvent of propionic anhydride and pyridine (5 : 2 was finally used for the derivation at 80°C for 3 min. Linear calibration curves were obtained in the concentration range of 25–2000.0 ng/mL, with a lower limit of quantification of 25 ng/mL. The intra- and interday precision (RSD values were below 13%, and the accuracy was in the range 87.2–108.5%. This developed method was successfully used for the determination of morphine and codeine in human urine for forensic identification study.

  20. Modeling Transport in Gas Chromatography Columns for the Micro-ChemLab

    Energy Technology Data Exchange (ETDEWEB)

    ADKINS,DOUGLAS R.; FRYE-MASON,GREGORY CHARLES; HUDSON,MARY L.; KOTTENSTETTE,RICHARD; MATZKE,CAROLYN M.; SALINGER,ANDREW G.; SHADID,JOHN N.; WONG, CHUNGNIN CHANN

    1999-09-01

    The gas chromatography (GC) column is a critical component in the microsystem for chemical detection ({mu}ChemLab{trademark}) being developed at Sandia. The goal is to etch a meter-long GC column onto a 1-cm{sup 2} silicon chip while maintaining good chromatographic performance. Our design strategy is to use a modeling and simulation approach. We have developed an analytical tool that models the transport and surface interaction process to achieve an optimized design of the GC column. This analytical tool has a flow module and a separation module. The flow module considers both the compressibility and slip flow effects that may significantly influence the gas transport in a long and narrow column. The separation module models analyte transport and physico-chemical interaction with the coated surface in the GC column. It predicts the column efficiency and performance. Results of our analysis will be presented in this paper. In addition to the analytical tool, we have also developed a time-dependent adsorption/desorption model and incorporated this model into a computational fluid dynamics (CFD) code to simulate analyte transport and separation process in GC columns. CFD simulations can capture the complex three-dimensional flow and transport dynamics, whereas the analytical tool cannot. Different column geometries have been studied, and results will be presented in this paper. Overall we have demonstrated that the modeling and simulation approach can guide the design of the GC column and will reduce the number of iterations in the device development.

  1. Modeling Transport in Gas Chromatography Columns for the Micro-ChemLab

    International Nuclear Information System (INIS)

    The gas chromatography (GC) column is a critical component in the microsystem for chemical detection ((mu)ChemLab(trademark)) being developed at Sandia. The goal is to etch a meter-long GC column onto a 1-cm(sup 2) silicon chip while maintaining good chromatographic performance. Our design strategy is to use a modeling and simulation approach. We have developed an analytical tool that models the transport and surface interaction process to achieve an optimized design of the GC column. This analytical tool has a flow module and a separation module. The flow module considers both the compressibility and slip flow effects that may significantly influence the gas transport in a long and narrow column. The separation module models analyte transport and physico-chemical interaction with the coated surface in the GC column. It predicts the column efficiency and performance. Results of our analysis will be presented in this paper. In addition to the analytical tool, we have also developed a time-dependent adsorption/desorption model and incorporated this model into a computational fluid dynamics (CFD) code to simulate analyte transport and separation process in GC columns. CFD simulations can capture the complex three-dimensional flow and transport dynamics, whereas the analytical tool cannot. Different column geometries have been studied, and results will be presented in this paper. Overall we have demonstrated that the modeling and simulation approach can guide the design of the GC column and will reduce the number of iterations in the device development

  2. CO2 corrosion of IG-110 nuclear graphite studied by gas chromatography

    International Nuclear Information System (INIS)

    The CO2 corrosion behavior of IG-110 nuclear graphite has been investigated using the gas chromatography method which allows the continuous analysis of the CO2/CO gas mixture at the outlet of the corrosion chamber. The effects of temperature and initial CO2 concentration are studied based on the Arrhenius-type reaction model. From 745 to 995°C, the Arrhenius curve shows a linear behavior. For higher temperatures, a non-linear behavior is observed. The activation energy is calculated as 210 kJ/mole and is independent of the initial CO2 inlet concentrations of 10%, 14% and 17%. The corrosion behavior at 1145°C, in the diffusion-controlled regime, has also been investigated. At this temperature, the interior of IG-110 graphite is severely attacked by CO2, and the material's surface morphology is changed drastically. A measurement of the corrosion rate against corrosion time shows that the corrosion rate initially increases to a maximum value at a weight loss degree of 30%-35%, after which it begins to decline. (author)

  3. A novel micropreconcentrator employing a laminar flow patterned heater for micro gas chromatography

    International Nuclear Information System (INIS)

    A simple micromachined process based on one photomask is developed for a novel micropreconcentrator (µPCT) used in a micro gas chromatograph (µGC). Unique thick silver heating microstructures with a high surface area for microheater of µPCT are fabricated by combining the microfluidic laminar flow technique and the Tollens’ reaction within a microchannel. Silver deposition using this laminar flow patterning technique provides a higher deposition rate and easier microfabrication compared to conventional micromachined technologies for thick metal microstructures (>200 µm). An amorphous and porous carbon film that functions as an adsorbent is grown on microheaters inside the microchannel. The µPCT can be heated to >300 °C rapidly by applying a constant electrical power of ∼1 W with a heating rate of 10 °C s−1. Four volatile organic compounds, acetone, benzene, toluene and xylene, are collected through the proposed novel µPCTs and separated successfully using a 17 m long gas chromatography column. The peak widths at half height (PWHHs) of the four compounds are relatively narrow (<6 s), and the minimum PWHH of 3.75 s is obtained for acetone. The preconcentration factors are >38 000 for benzene and toluene. (paper)

  4. Review of recent developments and applications in low-pressure (vacuum outlet) gas chromatography.

    Science.gov (United States)

    Sapozhnikova, Yelena; Lehotay, Steven J

    2015-10-29

    The concept of low pressure (LP) vacuum outlet gas chromatography (GC) was introduced more than 50 years ago, but it was not until the 2000s that its theoretical applicability to fast analysis of GC-amenable chemicals was realized. In practice, LPGC is implemented by placing the outlet of a short, wide (typically 10-15 m, 0.53 mm inner diameter) analytical column under vacuum conditions, which speeds the separation by reducing viscosity of the carrier gas, thereby leading to a higher optimal flow rate for the most separation efficiency. To keep the inlet at normal operating pressures, the analytical column is commonly coupled to a short, narrow uncoated restriction capillary that also acts as a guard column. The faster separations in LPGC usually result in worse separation efficiency relative to conventional GC, but selective detection usually overcomes this drawback. Mass spectrometry (MS) provides highly selective and sensitive universal detection, and nearly all GC-MS instruments provide vacuum outlet conditions for implementation of LPGC-MS(/MS) without need for adaptations. In addition to higher sample throughput, LPGC provides other benefits, including lower detection limits, less chance of analyte degradation, reduced peak tailing, increased sample loadability, and more ruggedness without overly narrow peaks that would necessitate excessively fast data acquisition rates. This critical review summarizes recent developments in the application of LPGC with MS and other detectors in the analysis of pesticides, environmental contaminants, explosives, phytosterols, and other semi-volatile compounds. PMID:26547491

  5. Characterization of Secondary Organic Aerosol Precursors Using Two-Dimensional Gas-Chromatography

    Science.gov (United States)

    Roskamp, M.; Lou, W.; Pankow, J. F.; Harley, P. C.; Turnipseed, A.; Barsanti, K. C.

    2012-12-01

    The oxidation of volatile organic compounds (VOCs) plays a role in both regional and global air quality. However, field and laboratory research indicate that the body of knowledge around the identities, quantities and oxidation processes of these compounds in the ambient atmosphere is still incomplete (e.g., Goldstein & Galbally, 2007; Robinson et al., 2009). VOCs emitted to the atmosphere largely are of biogenic origin (Guenther et al., 2006), and many studies of ambient secondary organic aerosol (SOA) suggest that SOA is largely of biogenic origin (albeit closely connected to anthropogenic activities, e.g., de Gouw and Jimenez, 2009). Accurate modeling of SOA levels and properties will require a more complete understanding of biogenic VOCs (BOCs) and their atmospheric oxidation products. For example, satellite measurements indicate that biogenic VOC emissions are two to three times greater than levels currently included in models (Heald et al., 2010). Two-dimensional gas chromatography (GC×GC) is a powerful analytical technique that shows much promise in advancing the state-of-knowledge regarding BVOCs and their role in SOA formation. In this work, samples were collected during BEACHON-RoMBAS (Bio-hydro-atmosphere Interactions of Energy, Aerosols, Carbon, H2O, Organics & Nitrogen - Rocky Mountain Biogenic Aerosol Study) in July and August of 2011. The field site was a Ponderosa Pine forest near Woodland, CO, inside the Manitou Experimental Forest, which is operated by the US Forest Service. The area is characteristic of the central Rocky Mountains and trace gas monitoring indicates that little anthropogenic pollution is transported from the nearby urban areas (Kim et al. 2010 and references therein). Ambient and enclosure samples were collected on ATD (adsorption/thermal desorption) cartridges and analyzed for BVOCs using two-dimensional gas chromatography (GC×GC) with time of flight mass spectrometry (TOFMS) and flame ionized detection (FID). Measurements of

  6. Pressure Tuning of First Dimension Columns in Comprehensive Two-Dimensional Gas Chromatography.

    Science.gov (United States)

    Sharif, Khan M; Kulsing, Chadin; Marriott, Philip J

    2016-09-20

    The experimental approach and mechanism of pressure tuning (PT) are introduced for the first stage of a comprehensive two-dimensional gas chromatography (GC × GC) separation. The PT-GC × GC system incorporates a first dimension ((1)D) coupled column ensemble comprising a pair of (1)D columns ((1)D1 and (1)D2) connected via a microfluidic splitter device, allowing variable decompression of carrier gas across each (1)D column, and a conventional (2)D narrow bore column. By variation of junction pressure between the (1)D1 and (1)D2 columns, tunable total (1)D retentions of analytes are readily derived. Separations of a standard mixture comprising a number of different chemical classes (including alkanes, monoaromatics, alcohols, aldehydes, ketones, and esters) and Australian tea tree oil (TTO) were studied as practical examples of the PT-GC × GC system application. This illustrated the change of analyte retention time with experimental conditions depending on void time and retention on the different columns. In addition to void time change, variation of carrier gas relative decompression in the (1)D ensemble leads to tunable contribution of the (1)D1/(1)D2 columns that changes apparent polarity and selectivity of the ensemble. The resulting changes in (1)D elution order further altered elution temperature and thus retention of each analyte on the (2)D column in temperature-programmed GC × GC. 2D orthogonality measurements were then conducted to evaluate overall separation performance under application of different (1)D junction pressure. As a result, distribution and selectivity of particular target compounds, monoterpenes, sesquiterpenes, and oxygenated terpenes in 2D space, and thus orthogonality, could be adequately tuned. This indicates the potential of PT-GC × GC to be applicable for practical sample separation and provides a general approach to tune selectivity of target compounds.

  7. Application of high-temperature gas chromatography to the analysis of used frying fats

    Directory of Open Access Journals (Sweden)

    Aguirre, M.

    2010-06-01

    Full Text Available The determination of polar compounds is the most commonly applied technique in the analysis of used frying fats and oils. High-temperature gas chromatography allows for a quantitative determination of oxidized monomeric FAME and dimeric FAME thus giving extra information on oil degradation starting from the fraction of polar compounds. Polar compounds are transesterified and methyl esters are separated in a VF-5ht Ultimetal column (150 °C -held for 5 min- rising at 5 °C min-1 to 370 °C and held for 5 min using methyl tricosanoate as internal standard. Results are compared with those obtained by more complex alternative methodology using high-performance size-exclusion chromatography.

    La determinación de compuestos polares es el método analítico más utilizado en el análisis de los aceites y grasas de fritura. En este estudio se aprovechan las posibilidades actuales de la cromatografía de gases a elevada temperatura que permite cuantificar los dos grupos mayoritarios de ácidos grasos polares como ésteres metílicos: los monómeros oxidados y los dímeros. Con tal fin, la fracción de compuestos polares se tranesterifica y los ésteres metílicos obtenidos se separan en una columna de VF-5ht Ultimetal, usando tricosanoato de metilo como estándar interno, en las siguientes condiciones: 150 °C durante 5 minutos, 5 °C/min hasta 370 °C y 5 minutos a 370 °C. Los resultados se comparan con los obtenidos mediante técnica alternativa más compleja basada en la cromatografía de exclusión por tamaño molecular.

  8. Determination of the origin of urinary norandrosterone traces by gas chromatography combustion isotope ratio mass spectrometry.

    Science.gov (United States)

    Hebestreit, Moritz; Flenker, Ulrich; Fusshöller, Gregor; Geyer, Hans; Güntner, Ute; Mareck, Ute; Piper, Thomas; Thevis, Mario; Ayotte, Christiane; Schänzer, Wilhelm

    2006-09-01

    On the one hand, 19-norandrosterone (NA) is the most abundant metabolite of the synthetic anabolic steroid 19-nortestosterone and related prohormones. On the other hand, small amounts are biosynthesized by pregnant women and further evidence exists for physiological origin of this compound. The World Anti-Doping Agency (WADA) formerly introduced threshold concentrations of 2 or 5 ng of NA per ml of urine to discriminate 19-nortestosterone abuse from biosynthetic origin. Recent findings showed however, that formation of NA resulting in concentrations in the range of the threshold levels might be due to demethylation of androsterone in urine, and the WADA 2006 Prohibited List has defined NA as endogenous steroid. To elucidate the endogenous or exogenous origin of NA, (13)C/(12)C-analysis is the method of choice since synthetic 19-nortestosterone is derived from C(3)-plants by partial synthesis and shows delta(13)C(VPDB)-values of around -28 per thousand. Endogenous steroids are less depleted in (13)C due to a dietary mixture of C(3)- and C(4)-plants. An extensive cleanup based on two high performance liquid chromatography cleanup steps was applied to quality control and doping control samples, which contained NA in concentrations down to 2 ng per ml of urine. (13)C/(12)C-ratios of NA, androsterone and etiocholanolone were measured by gas chromatography/combustion/isotope ratio mass spectrometry. By comparing delta(13)C(VPDB)-values of androsterone as endogenous reference compound with NA, the origin of NA in doping control samples was determined as either endogenous or exogenous.

  9. Partition coefficients of selected environmentally important volatile organic compounds determined by gas-liquid chromatography with polydimethylsiloxane stationary phase

    Energy Technology Data Exchange (ETDEWEB)

    Kloskowski, Adam [Physical Chemistry Department, The Chemical Faculty, Gdansk University of Technology Narutowicza 11/12, 80-462 Gdansk (Poland); Chrzanowski, Wojciech [Physical Chemistry Department, The Chemical Faculty, Gdansk University of Technology Narutowicza 11/12, 80-462 Gdansk (Poland)]. E-mail: wojtek@chem.pg.gda.pl; Pilarczyk, MichaI [Physical Chemistry Department, The Chemical Faculty, Gdansk University of Technology Narutowicza 11/12, 80-462 Gdansk (Poland); Namiesnik, Jacek [Analytical Chemistry Department, The Chemical Faculty, Gdansk University of Technology Narutowicza 11/12, 80-462 Gdansk (Poland)

    2005-01-01

    In this paper, partition coefficients (distribution constants) of 14 organic compounds of environmental importance (frequently determined in indoor air) between the gas and liquid phase (polydimethylsiloxane, PDMS) are presented, determined by two gas chromatographic methods: isothermal elution and temperature programmed elution using the LTPRI (linear temperature programme retention index) approach. We examined applicability of this approach to polar compounds. We took efforts to ensure best possible accuracy and trace the possible sources of error. Precision was estimated by reproducing the results using four chromatographic columns differing in diameter and stationary phase coating thickness. We consider some factors influencing the determination of thermodynamic quantities by gas chromatography and suggest some improvements.

  10. Application of capillary gas chromatography mass spectrometry/computer techniques to synoptic survey of organic material in bed sediment

    Science.gov (United States)

    Steinheimer, T.R.; Pereira, W.E.; Johnson, S.M.

    1981-01-01

    A bed sediment sample taken from an area impacted by heavy industrial activity was analyzed for organic compounds of environmental significance. Extraction was effected on a Soxhlet apparatus using a freeze-dried sample. The Soxhlet extract was fractionated by silica gel micro-column adsorption chromatography. Separation and identification of the organic compounds was accomplished by capillary gas chromatography/mass spectrometry techniques. More than 50 compounds were identified; these include saturated hydrocarbons, olefins, aromatic hydrocarbons, alkylated polycyclic aromatic hydrocarbons, and oxygenated compounds such as aldehydes and ketones. The role of bed sediments as a source or sink for organic pollutants is discussed. ?? 1981.

  11. Validation of a confirmatory method for the determination of melamine in egg by gas chromatography-mass spectrometry and ultra-performance liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    A sensitive and reliable method was developed and validated for detection and confirmation of melamine in egg based on gas chromatography-mass spectrometry (GC-MS) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Trichloroacetic acid solution was used for sample extraction and precipitation of proteins. The aqueous extracts were subjected to solid-phase extraction by mixed-mode reversed-phase/strong cation-exchange cartridges. Using ultra-performance liquid chromatography and electrospray ionization in the positive ion mode, melamine was determined by LC-MS/MS, which was completed in 5 min for each injection. For the GC-MS analysis, extracted melamine was derivatized with N,O-bis(trimethylsilyl)trifluoracetamide prior to selected ion monitoring detection in electron impact mode. The average recovery of melamine from fortified samples ranged from 85.2% to 103.2%, with coefficients of variation lower than 12%. The limit of detection obtained by GC-MS and UPLC-MS/MS was 10 and 5 μg kg-1, respectively. This validated method was successfully applied to the determination of melamine in real samples from market.

  12. Multivariate analysis of progressive thermal desorption coupled gas chromatography-mass spectrometry.

    Energy Technology Data Exchange (ETDEWEB)

    Van Benthem, Mark Hilary; Mowry, Curtis Dale; Kotula, Paul Gabriel; Borek, Theodore Thaddeus, III

    2010-09-01

    Thermal decomposition of poly dimethyl siloxane compounds, Sylgard{reg_sign} 184 and 186, were examined using thermal desorption coupled gas chromatography-mass spectrometry (TD/GC-MS) and multivariate analysis. This work describes a method of producing multiway data using a stepped thermal desorption. The technique involves sequentially heating a sample of the material of interest with subsequent analysis in a commercial GC/MS system. The decomposition chromatograms were analyzed using multivariate analysis tools including principal component analysis (PCA), factor rotation employing the varimax criterion, and multivariate curve resolution. The results of the analysis show seven components related to offgassing of various fractions of siloxanes that vary as a function of temperature. Thermal desorption coupled with gas chromatography-mass spectrometry (TD/GC-MS) is a powerful analytical technique for analyzing chemical mixtures. It has great potential in numerous analytic areas including materials analysis, sports medicine, in the detection of designer drugs; and biological research for metabolomics. Data analysis is complicated, far from automated and can result in high false positive or false negative rates. We have demonstrated a step-wise TD/GC-MS technique that removes more volatile compounds from a sample before extracting the less volatile compounds. This creates an additional dimension of separation before the GC column, while simultaneously generating three-way data. Sandia's proven multivariate analysis methods, when applied to these data, have several advantages over current commercial options. It also has demonstrated potential for success in finding and enabling identification of trace compounds. Several challenges remain, however, including understanding the sources of noise in the data, outlier detection, improving the data pretreatment and analysis methods, developing a software tool for ease of use by the chemist, and demonstrating our belief

  13. Cromatografia unificada Unified chromatography

    Directory of Open Access Journals (Sweden)

    Carin von Mühlen

    2004-10-01

    Full Text Available The scope of this study encompasses an overview of the principles of unified chromatography as well as the principles of chromatographic techniques as applied to unified systems, which include gas chromatography, liquid chromatography, supercritical fluid chromatography, high temperature and high pressure liquid chromatography, micro-liquid chromatography, enhanced fluidity chromatography, and solvating gas chromatography. Theoretical considerations and individual instrumental parameters such as mobile phase, sample introduction system, columns, and detection system are also discussed. Future applications of this separation approach are discussed.

  14. Detection of radiation-induced hydrocarbons in irradiated fish and prawns by means of on-line coupled liquid chromatography-gas chromatography

    International Nuclear Information System (INIS)

    Radiation-induced hydrocarbons were analyzed in a fatty (halibut) and a lean fish (cod) as well as in a prawn species by on-line coupled liquid chromatography (LC) -gas chromatography (GC) combined with mass spectrometry. In irradiated halibut which is known to contain mainly saturated and monounsaturated fatty acids, all expected radiolytic alkanes, alkenes, and alkadienes could be detected. The yields of the C(n-1) and C(n-2:1) hydrocarbons were comparable to those found in irradiated lipids of terrestrial animals and plants. However, in cod and prawns which contain high levels of polyunsaturated fatty acids (PUFA), the C(n-1) hydrocarbons were found in concentrations which were up to 10 times higher whereas the C(n-2:1) products were again comparable to those of terrestrial animals and plants. The identification of radiation-induced hydrocarbons in fish lipids was achieved by transfer of the hydrocarbons from the LC column to the gas chromatographic column in fractions differing in their degree of unsaturation. For the first time, radiation-induced hydrocarbons with more than four double bonds generated from polyunsaturated fatty acids (20:4 omega 6 and 20:5 omega 3) could be identified

  15. Performance evaluation of a versatile multidimensional chromatographic preparative system based on three-dimensional gas chromatography and liquid chromatography-two-dimensional gas chromatography for the collection of volatile constituents.

    Science.gov (United States)

    Pantò, Sebastiano; Sciarrone, Danilo; Maimone, Mariarosa; Ragonese, Carla; Giofrè, Salvatore; Donato, Paola; Farnetti, Sara; Mondello, Luigi

    2015-10-23

    The present research deals with the multi-collection of the most important sesquiterpene alcohols belonging to sandalwood essential oil, as reported by the international regulations: (Z)-α-santalol, (Z)-α-trans bergamotol, (Z)-β-santalol, epi-(Z)-β-santalol, α-bisabolol, (Z)-lanceol, and (Z)-nuciferol. A versatile multidimensional preparative system, based on the hyphenation of liquid and gas chromatography techniques, was operated in the LC-GC-GC-prep or GC-GC-GC-prep configuration, depending on the concentration to be collected from the sample, without any hardware or software modification. The system was equipped with a silica LC column in combination with polyethylene glycol-poly(5% diphenyl/95% dimethylsiloxane)-medium polarity ionic liquid or β-cyclodextrin based GC stationary phases. The GC-GC-GC-prep configuration was exploited for the collection of four components, by using a conventional split/splitless injector, while the LC-GC-GC-prep approach was applied for three low abundant components (87%).

  16. A Chemical Detector for Gas Chromatography Using Pulsed Discharge Emission Spectroscopy on a Microchip

    Science.gov (United States)

    Luo, X.; Zhu, W.; Mitra, B.; Liu, J.; Liu, T.; Fan, X.; Gianchandani, Y.

    2011-12-01

    There is increasing interest in miniaturized systems for chemical analysis in harsh environments. Chemical detection by emission spectroscopy of on-chip microdischarges [1-3] can be performed at >200°C [4], suggesting utility inspace exploration, volcanic monitoring, and oil well monitoring. This abstract describes the first use of pulsed microdischarge spectroscopy for gas chromatography (GC).This effort supports NASA interests in monitoring closed-loop life support systems for spacecraft. The microdischarge occurs on a 1cm2 glass chip (Fig. 1a), with thin-film Ni electrodes separated by 160μm. A glass lid with a grooved gas-flow channel, and inlet/outlet capillary tubes are epoxy-sealed to the chip. Located downstream of the 1.7m-long, RTX-1-coated, GC separation column, the microdischarge chip is read by a spectrometer. In a typical experiment (Fig. 1b), a mixture of acetone 3.6μg, 1-hexanol 2.8μg and nitrobenzene 3.0μg, is injected, with He carrier gas at 1.56sccm, through the GC. Acetone elutes quickly while nitrobenzene is slower. Microdischarges are triggered at 0.5Hz for 6 min., and 0.04Hz thereafter. Each microdischarge consumes ≈8mJ; the average power is ≈1.14mW. The spectrum (Fig. 1b, inset) shows that the 388nm peak, representing CN/CH fragments [5], is enhanced by carbon compounds. Its strength relative to the 588nm peak of He provides a chromatogram. Fig. 1b also shows a benchmark result from a commercial flame ionization detector (FID). The differences in elution time are attributed to differences in the gas flow paths for the two detectors [1]. REFERENCES [1] Eijkel et al, Anal. Chem, 2000 [2] Mitra et al, IEEE Trans Plasma Sci, 2008 [3] Mitra et al, IEEE Sensors, 2008 [4] Wright et al, APL, 2009 [5] Pearse et al, The Identification of Molecular Spectra, 1963

  17. On the Principle and Application of Gas Chromatography%关于气相色谱仪原理组成及使用的思考

    Institute of Scientific and Technical Information of China (English)

    厉昌海; 林隆海

    2016-01-01

    本文着重对气相色谱仪的工作原理进行分析,介绍了气相色谱分析仪的组成结构,在此基础上针对气相色谱分析仪使用过程展开论述,说明了如何才能更好的使用气相色谱分析仪%This paper mainly analyzes the working principle of gas chromatography, introduces the composition structure of gas chromatography and gas chromatography analyzer.

  18. Gas chromatography coupled with atomic absorption spectrometry — a sensitive instrumentation for mercury speciation

    Science.gov (United States)

    Emteborg, Håkan; Sinemus, Hans-Werner; Radziuk, Bernard; Baxter, Douglas C.; Frech, Wolfgang

    1996-07-01

    New instrumentation for the speciation of mercury is described, and is applied to the analysis of natural water samples. The separation of mercury species is effected using gas chromatography of derivatized mercury species on a widebore capillary column. The solvent is vented using a bypass valve and the separated mercury species are pyrolysed on-line at 800°C for production of mercury atoms. These are then detected by atomic absorption spectrometry (AAS) at the 253.7 and 184.9 nm lines simultaneously in a quartz cuvette. The use of the 184.9 nm line provides a more than five-fold increase in sensitivity compared with the conventional 253.7 nm line and an absolute detection limit of 0.5 pg of mercury. The dynamic range of the combined analytical lines provides a linear response over more than three orders of magnitude. A number of organic compounds not containing mercury are also detected following pyrolysis, especially at the 184.9 nm line. These background species must not co-elute at the retention times for methyl- and inorganic mercury, as otherwise a positive interference would result. By maximizing the chromatographic resolution and minimizing the band broadening in the cuvette by use of a make-up gas, the retention times of interest are freed from co-eluting background peaks. The instrumentation has been applied to the determination of ng l -1 concentrations of methyl- and inorganic mercury in Lake Constance, Germany and within the Lake Constance drinking water supply organization, Bodenseewasserversorgung (BWV). The accuracy for the sum of methyl- and inorganic mercury has been assessed by comparison with an independent method for total mercury based on AAS detection implemented at BWV. Relative detection limits using 1 litre water samples and 15 ml injections of the final hexane extract were 0.03 ng l -1 for methylmercury and 0.4 ng l -1 for inorganic mercury based on the 3j criterion.

  19. Improved micromachined column design and fluidic interconnects for programmed high-temperature gas chromatography separations.

    Science.gov (United States)

    Gaddes, David; Westland, Jessica; Dorman, Frank L; Tadigadapa, Srinivas

    2014-07-01

    This work focuses on the development and experimental evaluation of micromachined chromatographic columns for use in a commercial gas chromatography (GC) system. A vespel/graphite ferrule based compression sealing technique is presented using which leak-proof fluidic interconnection between the inlet tubing and the microchannel was achieved. This sealing technique enabled separation at temperatures up to 350°C on a μGC column. This paper reports the first high-temperature separations in microfabricated chromatographic columns at these temperatures. A 2m microfabricated column using a double Archimedean spiral design with a square cross-section of 100μm×100μm has been developed using silicon microfabrication techniques. The microfabricated column was benchmarked against a 2m 100μm diameter commercial column and the performance between the two columns was evaluated in tests performed under identical conditions. High temperature separations of simulated distillation (ASTM2887) and polycyclic aromatic hydrocarbons (EPA8310) were performed using the μGC column in temperature programmed mode. The demonstrated μGC column along with the high temperature fixture offers one more solution toward potentially realizing a portable μGC device for the detection of semi-volatile environmental pollutants and explosives without the thermal limitations reported to date with μGC columns using epoxy based interconnect technology.

  20. Vinegar Metabolomics: An Explorative Study of Commercial Balsamic Vinegars Using Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    Pinu, Farhana R.; de Carvalho-Silva, Samuel; Trovatti Uetanabaro, Ana Paula; Villas-Boas, Silas G.

    2016-01-01

    Balsamic vinegar is a popular food condiment produced from cooked grape must by two successive fermentation (anaerobic and aerobic) processes. Although many studies have been performed to determine the composition of major metabolites, including sugars and aroma compounds, no study has been undertaken yet to characterize the comprehensive metabolite composition of balsamic vinegars. Here, we present the first metabolomics study of commercial balsamic vinegars by gas chromatography coupled to mass spectrometry (GC-MS). The combination of three GC-MS methods allowed us to detect >1500 features in vinegar samples, of which 123 metabolites were accurately identified, including 25 amino acids, 26 carboxylic acids, 13 sugars and sugar alcohols, four fatty acids, one vitamin, one tripeptide and over 47 aroma compounds. Moreover, we identified for the first time in vinegar five volatile metabolites: acetin, 2-methylpyrazine, 2-acetyl-1-pyroline, 4-anisidine and 1,3-diacetoxypropane. Therefore, we demonstrated the capability of metabolomics for detecting and identifying large number of metabolites and some of them could be used to distinguish vinegar samples based on their origin and potentially quality. PMID:27455339

  1. Determination of Synthetic Cathinones in Urine Using Gas Chromatography-Mass Spectrometry Techniques.

    Science.gov (United States)

    Hong, Wei-Yin; Ko, Ya-Chun; Lin, Mei-Chih; Wang, Po-Yu; Chen, Yu-Pen; Chiueh, Lih-Ching; Shih, Daniel Yang-Chih; Chou, Hsiu-Kuan; Cheng, Hwei-Fang

    2016-01-01

    In recent years, the abuse of synthetic cathinones has increased considerably. This study proposes a method, based on gas chromatography/mass spectrometry (GC-MS), to analyze and quantify six synthetic cathinones in urine samples: mephedrone (4-MMC), methylone (bk-MDMA), butylone, ethylone, pentylone and methylenedioxypyrovalerone (MDPV). In our procedure, the urine samples undergo solid-phase extraction (SPE) and derivatization prior to injection into the GC-MS device. Separation is performed using a HP-5MS capillary column. The use of selective ion monitoring (SIM mode) makes it is good sensitivity in this method, and the entire analysis process is within 18 min. In addition, the proposed method maintains linearity in the calibration curve from 50 to 2,000 ng/mL (r(2) > 0.995). The limit of detection of this method is 5 ng/mL, with the exception of MDPV (20 ng/mL); the limit of quantification is 20 ng/mL, with the exception of MDPV (50 ng/mL). In testing, the extraction performance of SPE was between 82.34 and 104.46%. Precision and accuracy results were satisfactory MDMA. Our results demonstrate the efficacy of the proposed method in the identification of synthetic cathinones in urine, with regard to the limits of detection and quantification. This method is highly repeatable and accurate. PMID:26410364

  2. Pyrolysis of Polytrimethylene Terephthalate (PTT) Fiber by Pyrolysis Gas Chromatography-Mass Spectroscopy

    Institute of Scientific and Technical Information of China (English)

    QIAN He-sheng

    2007-01-01

    Pyrolysis of polytrimethylene terephthalate (PTT) fiber has been investigated by pyrolysis gas chromatography-mass spectroscopy in the temperature range from 400℃ to 750℃ in order to observe the possible effect of the temperature on its composition of pyrolysates. At 400℃, pyrolysis of molecular chain could occur, only 13 pyrolysates could be identified. The trimethylene moieties bound to the macromolecular core by ester bonds are cleaved at around 400℃. At 550℃ -750℃, pyrolysis of molecular chain could completely take place, 46 pyrolysates could be found. As the temperature increases, the compositions of pyrolysate are distinctly increased. Several compounds, especially benzoic acid, monopropenyl-p-phthalate, 2 - propenyl benzoate, di - 2 - propenyl ester, 1,4 -benzenedicarboxylic acid, benzene, 1, 5 - hexadiene, biphenyl and 1, 3 - propanediol dibenzoate could be formed. The thermal degradation mechanism, which is determined by structure and amount of the thermal decomposition products, are described. During pyrolysis of polytrimethylene terephthalate, polymeric chain scissions take place a peeling reaction as a successive removal of the dimer units from the polymeric chain. The chain scissions are followed by the elimination reaction, linkage action and secondary reactions, which bring about a variety fragment.

  3. Identification and determination of erucic acid in infant formula using Gas Chromatography

    Directory of Open Access Journals (Sweden)

    Sabzevari O

    2007-05-01

    Full Text Available Background: Infant formula, depending on the source, contains various fatty acids, which may possess important nutritional and biological value for infants. The presence of some of these fatty acids in infant formula, however, can be harmful and toxic for the infant. In this regard, more attention has been paid to erucic acid since its accumulation in myocardial tissues may cause damage to the heart. Therefore, a limit has been set by the Codex Alimentarius for the presence of erucic acid in infant formula (less than 1% of total fatty acids. The purpose of the present study is to investigate amount of erucic acid present in three infant formulas used predominantly in Iran. Methods: Gas chromatography (GC is a valuable method applied for the separation of fatty acids, including erucic acid, from oils and oily food. Three brands of infant formulas, namely Humana, Biomil and Multi, were analyzed by GC using a wall coated open tubular (WCOT fused silica column and flame ionization detector (FID. Heneicosanoic acid was employed as an internal standard. Results: The findings showed that Humana and Biomil infant formula samples contained 0.06% and 0.002% erucic acid (from total fatty acids, respectively, while no erucic acid was detected in the Multi infant formula samples. Conclusion: The amount of erucic acid in the studied infant formulas was far below the Codex limit of 1% total fatty acids.

  4. Improved sensitivity gas chromatography-mass spectrometry determination of parabens in waters using ionic liquids.

    Science.gov (United States)

    Cacho, Juan Ignacio; Campillo, Natalia; Viñas, Pilar; Hernández-Córdoba, Manuel

    2016-01-01

    A new procedure for the introduction of ionic liquid samples in gas chromatography (GC) is proposed. This procedure, based on microvial insert thermal desorption, allows the direct analysis of the compounds preconcentrated by ionic liquid based liquid-liquid microextraction (IL-LLME) using the combination of a thermal desorption unit (TDU) and a programmed temperature vaporization injector (PTV). Two different IL-LLME methodologies, one based on the formation of a microdroplet emulsion by dispersive liquid-liquid microextraction (DLLME) and other through ultrasound-assisted emulsification microextraction (USAEME) were studied and evaluated. IL-DLLME proved advantageous and consequently, it was adopted for preconcentration purposes. This easy to apply approach was used for the determination of five parabens (methyl-, ethyl-, propyl-, butyl- and isobutyl paraben) in swimming pool waters, after in situ acetylation. The optimized conditions of TDU/PTV allowed the analytes contained in 20 µL of the enriched IL to be transferred to the capillary column. Quantification of the samples was carried out against aqueous standards, and quantification limits of between 4.3 and 8.1 ng L(-1) were obtained, depending on the compound. Concentrations of between 9 and 47 ng L(-1) for some analytes were obtained in the analysis of ten samples. PMID:26695305

  5. Determination of terpenes in tequila by solid phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Peña-Alvarez, Araceli; Capella, Santiago; Juárez, Rocío; Labastida, Carmen

    2006-11-17

    Solid phase microextraction and capillary gas chromatography-mass spectrometry were used for the determination of seven terpenes in tequila. The method was selected based on the following parameters: coating selection (PA, PDMS, CW/DVB, and PDMS/DVB), extraction temperature, addition of salt, and extraction time profile. The extraction conditions were: PDMS/DVB fiber, Headspace, 100% NaCl, 25 degrees C extraction temperature, 30 min extraction time and stirring at 1200 rpm. The calibration curves (50-1000 ng/ml) for the terpenes followed linear relationships with correlation coefficients (r) greater than 0.99, except for trans,trans-farnesol (r = 0.98). RSD values were smaller than 10% confirmed that the technique was precise. Samples from 18 different trade brands of "Aged" tequila analyzed with the developed method showed the same terpenes in different concentrations. The analytical procedure used is selective, robust (more than 100 analyses with the same fiber), fast and of low-cost.

  6. Surface modification of CaCO3 filler and its characterization using inverse gas chromatography (IGC)

    Institute of Scientific and Technical Information of China (English)

    Guangcheng ZHANG; Xuetao SHI; Yajuan XING; Ting CHEN

    2008-01-01

    A CaCO3 filler was treated by generally used coupling agents and a special one-ethylene-octene copolymer (POE)-g-maleic anhydride (MAH). Fourier transform infrared spectroscopy (FTIR) results show that the special coupling agent POE-g-MAH, in a chemical reaction with CaCO3, can produce an interfacial layer stronger than simple physical adhesion attained with usual coupling agents. Inverse gas chromatography (IGC) was used to investigate the surface free energy of CaCO3 after surface modification and to optimize the monolayer content of coupling agents. Based on the IGC results, it can be deduced that the monolayer cover is around 1.9% for CaCO3 treated with a titanate coupling agent. Scanning electron microscope (SEM) observation results show that the separated morphology existed in the ternary composites containing CaCO3 after surface treatment with coupling agents, whereas the core-shell morphology was obtained in the ternary composites with POE-g-MAH. The encapsulation of the CaCO3 filler treated with POE-g-MAH was caused by the strong chemical reaction between the elastomer and CaCO3 particles.

  7. Determination of ethanol content in medicated syrups by static headspace gas chromatography.

    Science.gov (United States)

    Huzar, Elźbieta; Wodnicka, Alicja

    2013-01-01

    Liquid drug preparations are the most convenient for pediatric patients. Unfortunately, these formulations very often contain ethanol, which may have an impact on children development. Moreover, medicines containing alcohol may cause undesirable interactions in conjunction with other drugs. This work reports complete validated method for the quantitation of ethanol in commercial medicated syrups. For determination of ethanol headspace gas chromatography and different methods of quantitative analysis were used. The analyzed samples of commercial medicated syrups available on the home marked contained from 3.37 to 8.65% (v/v) of ethanol. The estimated theoretical values of blood ethanol concentration for children after single recommended dose ingestion were at least twice lower than 0.125 g/mL. The process of validation showed that the applied GC method is selective, sensitive, linear and precise. The use of internal standard makes it accurate. The developed method could be considered as an analytical tool for the quality control of various liquid drug preparations.

  8. Multi-class method for biomonitoring of hair samples using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Martín, Julia; Möder, Monika; Gaudl, Alexander; Alonso, Esteban; Reemtsma, Thorsten

    2015-11-01

    Currently, non-invasive biomonitoring of human exposure to organic pollutants bases upon the analysis mainly of urine and human breast milk. While mostly persistent organic pollutants are the center of interest, the aim of our study was to develop a method for the determination of different chemical classes of emerging pollutants (organophosphorus flame retardants, plastic additives such as phthalates, bisphenol A, insecticides, antimicrobials, preservatives and musk fragrances) in hair by gas chromatography-mass spectrometry. The preferred sample preparation included hydrolysis of the hair with trifluoroacetic acid in methanol followed by a liquid-liquid extraction using hexane/ethyl acetate. The validated method is characterized by recoveries higher than 77 % for most analytes, relative standard deviations below 16 % and limits of detection between 2 pg mg(-1) (HHCB) and 292 pg mg(-1) (propylparaben) using 50 mg of dry hair. After respective blank corrections, bis-(2-ethylhexyl)phthalate (DEHP) and the musk fragrance HHCB were the predominant compounds determined in all hair samples at concentrations between 32 and 59 ng mg(-1) and 0.8-13 ng mg(-1), respectively. The bactericide triclosan and the insect repellent N,N-diethyl-3-methylbenzamide (DEET) were detected in selected hair samples at 2 and 0.8 ng mg(-1), respectively. PMID:26427497

  9. [Dead time determination of the second dimension in a comprehensive two-dimensional gas chromatography].

    Science.gov (United States)

    Kong, Hongwei; Ye, Fen; Lu, Xin; Dong, Mingquan; Guo, Lei; Xu, Guowang

    2005-01-01

    Comprehensive two-dimensional gas chromatography (GC x GC) is rapidly gaining importance for the analysis of complex samples. In order to predict chromatogram and optimize the operational conditions, the dead time of each dimension should be obtained exactly. Two methods to calculate the dead time of the second dimension were introduced. In the first method, based on the relationship between the time differences of a series of n-alkanes substances and the apparent retention times under different pressures, the true retention time can be calculated for non-synchronous GC x GC. The retention times of homologous series were used to calculate the dead time. Another rapid method to calculate the dead time of the second dimension is based on three or more apparent retention times in a single temperature programmed chromatographic run. The results show that the dead time of the second dimension can be calculated successfully by using the proposed methods and the deviation between the two methods is less than 0.05 s. PMID:15881364

  10. Alternative sorptive extraction method for gas chromatography determination of halogenated anisoles in water and wine samples

    Energy Technology Data Exchange (ETDEWEB)

    Montes, R. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Instituto de Investigacion y Analisis Alimentario, Universidad de Santiago de Compostela, Santiago de Compostela 15782 (Spain); Rodriguez, I. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Instituto de Investigacion y Analisis Alimentario, Universidad de Santiago de Compostela, Santiago de Compostela 15782 (Spain)], E-mail: qnisaac@usc.es; Rubi, E.; Bollain, M.H.; Cela, R. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Instituto de Investigacion y Analisis Alimentario, Universidad de Santiago de Compostela, Santiago de Compostela 15782 (Spain)

    2007-09-05

    An alternative sorptive microextraction method for the determination of five halogenated anisoles in water and wine matrices is proposed. Analytes were concentrated in an inexpensive and disposable piece of bulk polydimethylsiloxane (PDMS), desorbed with a small volume of organic solvent, and determined by gas chromatography with electron-capture detection (GC-ECD) or tandem mass spectrometry (GC-MS/MS). The influence of several factors on the efficiency of extraction and desorption steps was investigated in detail and the observed behaviour justified on the basis of thermodynamics and kinetics of the solid-phase microextraction technique. Under optimised conditions, analytes were first extracted in the headspace (HS) mode, at room temperature, for 2.5 h and then desorbed with 1 mL of n-pentane. This extract was further evaporated to 50 {mu}L. The overall extraction yield of the procedure ranged from 40 to 55% and the limits of quantification remained between 0.5 and 20 ng L{sup -1}, depending on the compound considered and the detection technique. Precision and linearity of the method were excellent for all species with both GC-ECD and GC-MS/MS detection. Matrix effects were evaluated with different water and wine samples; moreover, the suitability of the PDMS sorbent for storage of analytes, under different conditions, was demonstrated.

  11. Postmortem interval estimation: a novel approach utilizing gas chromatography/mass spectrometry-based biochemical profiling.

    Science.gov (United States)

    Kaszynski, Richard H; Nishiumi, Shin; Azuma, Takeshi; Yoshida, Masaru; Kondo, Takeshi; Takahashi, Motonori; Asano, Migiwa; Ueno, Yasuhiro

    2016-05-01

    While the molecular mechanisms underlying postmortem change have been exhaustively investigated, the establishment of an objective and reliable means for estimating postmortem interval (PMI) remains an elusive feat. In the present study, we exploit low molecular weight metabolites to estimate postmortem interval in mice. After sacrifice, serum and muscle samples were procured from C57BL/6J mice (n = 52) at seven predetermined postmortem intervals (0, 1, 3, 6, 12, 24, and 48 h). After extraction and isolation, low molecular weight metabolites were measured via gas chromatography/mass spectrometry (GC/MS) and examined via semi-quantification studies. Then, PMI prediction models were generated for each of the 175 and 163 metabolites identified in muscle and serum, respectively, using a non-linear least squares curve fitting program. A PMI estimation panel for muscle and serum was then erected which consisted of 17 (9.7%) and 14 (8.5%) of the best PMI biomarkers identified in muscle and serum profiles demonstrating statistically significant correlations between metabolite quantity and PMI. Using a single-blinded assessment, we carried out validation studies on the PMI estimation panels. Mean ± standard deviation for accuracy of muscle and serum PMI prediction panels was -0.27 ± 2.88 and -0.89 ± 2.31 h, respectively. Ultimately, these studies elucidate the utility of metabolomic profiling in PMI estimation and pave the path toward biochemical profiling studies involving human samples. PMID:26931122

  12. Identification of tartary buckwheat tea aroma compounds with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Qin, Peiyou; Ma, Tingjun; Wu, Li; Shan, Fang; Ren, Guixing

    2011-08-01

    Tartary buckwheat tea, which is an important and healthy product, has a distinct malty aroma. However, its characteristic aroma compounds have not been elucidated. The aims of present study were identification and quantification of its aroma compounds. The analyses were performed by gas chromatography-mass spectrometry (GC-MS) after 3 different isolation techniques. Seventy-seven compounds were identified. Among these compounds, 35 were quantified by available standards. The compounds with a high probability of contribution to the tartary buckwheat tea aroma (OAV ≥ 10) were as follows: 2,5-dimethyl-4-hydroxy-3(2H)-furanone, nonanal, 2,3-diethyl-5-methylpyrazine, benzeneacetaldehyde, maltol, 2,5-dimethylpyrazine, 2-ethyl-5-methylpyrazine, trimethylpyrazine. Some nutritional and bioactive compounds were also identified in this study, such as linoleic acid, niacin, vanillic acid, 7-hydroxycoumarin, butylated hydroxytoluene. Practical Application: Tartary buckwheat, one type of buckwheat, has gained much attention from nutritionists and medical doctors in recent years. It is rich in rutin, quercetin, and other nutrients that are good for health. Tartary buckwheat-based product such as tartary buckwheat tea is an important and popular healthy product in China, Japan,South Korea, European countries as well as in American countries. It has a distinct malty aroma. The present study first identified and quantified of its aroma compounds. The results will draw attention to other researchers in food flavor and buckwheat filed. PMID:22417522

  13. Analysis of endogenous aldehydes in human urine by static headspace gas chromatography-mass spectrometry.

    Science.gov (United States)

    Serrano, María; Gallego, Mercedes; Silva, Manuel

    2016-03-11

    Endogenous aldehydes (EAs) generated during oxidative stress and cell processes are associated with many pathogenic and toxicogenic processes. The aim of this research was to develop a solvent-free and automated analytical method for the determination of EAs in human urine using a static headspace generator sampler coupled with gas chromatography-mass spectrometry (HS-GC-MS). Twelve significant EAs used as markers of different biochemical and physiological processes, namely short- and medium-chain alkanals, α,β-unsaturated aldehydes and dicarbonyl aldehydes have been selected as target analytes. Human urine samples (no dilution is required) were derivatized with O-2,3,4,5,6-pentafluorobenzylhydroxylamine in alkaline medium (hydrogen carbonate-carbonate buffer, pH 10.3). The HS-GC-MS method developed renders an efficient tool for the sensitive and precise determination of EAs in human urine with limits of detection from 1 to 15ng/L and relative standard deviations, (RSDs) from 6.0 to 7.9%. Average recoveries by enriching urine samples ranged between 92 and 95%. Aldehydes were readily determined at 0.005-50μg/L levels in human urine from healthy subjects, smokers and diabetic adults.

  14. Forensic profiling of sassafras oils based on comprehensive two-dimensional gas chromatography.

    Science.gov (United States)

    Schäffer, M; Gröger, T; Pütz, M; Zimmermann, R

    2013-06-10

    Safrole, the main compound in the essential oil of several plants of the Laurel family (Lauraceae), and its secondary product piperonylmethylketone are the predominantly used precursors for the illicit synthesis of 3,4-methylenedioxymethamphetamine (MDMA) which is, in turn, the most common active ingredient in Ecstasy tablets. Analytical methods with adequate capacity to identify links and origin of precursors, such as safrole, provide valuable information for drug-related police intelligence. Authentic sassafras oil samples from police seizures were subjected to comparative analysis based on their chemical profiles obtained by comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC-TOFMS). The enhanced separation power and increased sensitivity of GC × GC allowed for the detection of minor compounds present in the essential oils which were of particular interest in case of very pure samples whose impurity profiles were not very pronounced. Discrimination of such samples was still possible even in the absence of characteristic main compounds.

  15. Analysis of residual toluene in food packaging via headspace extraction method using gas chromatography

    International Nuclear Information System (INIS)

    Polymeric materials are used in many food contact applications as packaging material. The presence of residual toluene in this food packaging material can migrate into food and thus affect the quality of food. In this study, a manual headspace analysis was successfully designed and developed. The determination of residual toluene was carried out with standard addition method and multiple headspace extraction, MHE) method using gas chromatography-flame ionization detector, GC-FID). Identification of toluene was performed by comparison of its retention time with standard toluene and GC-MS. It was found that the suitable heating temperature was 180 degree Celsius with an optimum heating time of 10 minutes. The study also found that the concentration of residual toluene in multicolored sample was higher compared to mono colored sample whereas residual toluene in sample analyzed using standard addition method was higher compared to MHE method. However, comparison with the results obtained from De Paris laboratory, France found that MHE method gave higher accuracy for sample with low analyte concentration. On the other hand, lower accuracy was obtained for sample with high concentration of residual toluene due to systematic errors. Comparison between determination methods showed that MHE method is more precise compared to standard addition method. (author)

  16. The analysis of common metabolites of organophosphorus pesticides in urine by gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Most organophosphorus pesticides may be metabolized to yield some common phosphates in human or in animals, and these metabolites may be used as the exposure biomarkers to pesticides. In this study, we developed the extraction method of four phosphate metabolites from the spiked human urine in high recovery by the solid phase extraction with a reverse-phase cartridge (cyclohexyl silica) followed by the elution with methanol. The extracted urinary metabolites were derivatized with hexamethyldisilazane/trimethyl-chlorosilane/pyridine (2:1:10, v/v/v) and identified by gas chromatography/mass spectrometry. Calibration curve obtained from each metabolite standard using by GC/MS/SIM has shown good linearity and detection limits of metabolites were the range of 0.05-0.1 μg/ml in urine. Phenthoate, one of the organophosphorus pesticides, was orally administrated to rats. Four metabolites were detected in the rat urine. The results of this study may be applied to development of exposure biomarkers for monitoring of environmental pollutants

  17. Characterization of 22 Vibrio species by gas chromatography analysis of their cellular fatty acids.

    Science.gov (United States)

    Urdaci, M C; Marchand, M; Grimont, P A

    1990-05-01

    The cellular fatty acid compositions of 51 Vibrio strains belonging to 22 species as well as five Aeromonas strains were determined by using capillary gas-liquid chromatography (GLC). The major fatty acids were most often hexadecenoic, hexadecanoic and octadecenoic acids. Heptadecenoic acid was present in significant amounts in V. alginolyticus, V. natriegens, V. parahaemolyticus and "Vibrio navarrensis". Twenty fatty acids including branched and hydroxy acids were detected in the genus Vibrio. Quantitative results were treated by principal component analysis to display groups of strains. The first three components (accounting for 69% of the variance) showed the type strains of V. fischeri, V. ordalii, V. damsela, V. mediterranei, V. tubiashii, V. campbellii, V. pelagius, V. gazogenes, and V. nereis to be unclustered. V. alginolyticus (4 strains) and V. parahaemolyticus (4 strains) showed some overlap and the type strain of V. natriegens was in their neighborhood. V. harveyi (4 strains) formed a cluster and V. vulnificus was in its vicinity. V. cholerae (5 strains) overlapped with V. diazotrophicus (3 strains) and was close to the type strain of V. mimicus and V. anguillarum. V. metschnikovii (3 strains) clustered with the type strain of V. cincinnatiensis. A decision tree was devised for the identification of Vibrio species based on qualitative characteristics of fatty acid patterns. However, the following three groups, V. alginolyticus-V. parahaemolyticus-V. natriegens, V. metschnikovii-V. cincinnatiensis and V. cholerae-V. mimicus could not be split into such a decision tree.

  18. Fluoro-substituted tetraphenyl-phenyl grafted polysiloxanes as highly selective stationary phases for gas chromatography.

    Science.gov (United States)

    Han, Xue; He, Xinxin; Wang, Huan; Wang, Bing; Wu, Bo

    2016-06-01

    In this work, two new types of polycyclic aromatic grafted polysiloxanes, namely, 3,4-bis(4-fluoro phenyl)-2,5-diphenyl polysiloxane (FPP) and 3,4-bis(3,4,5-trifluoro phenyl)-2,5-diphenyl polysiloxane (TFPP), were synthesized and statically coated onto capillary columns as stationary phases for gas chromatography (GC). Based on their McReynolds constants, both columns exhibited moderate polarity. The efficiencies of the FPP and TFPP columns were 3316 (k=3.96, naphthalene; 0.25mm inner diameter) and 3768 (k=4.14, naphthalene; 0.25mm inner diameter) plates/m, respectively. The thermostability of the polymers was tested by thermogravimetric analysis (TGA), and results revealed that both TFPP and FPP began to decompose slightly at 380°C. Separation of polyethylene pyrolysis products showed that the upper working temperature of the two columns can reach up to 360°C. Relying on their unique polarizable characteristics in combination with other types of interactions, such as H-bond acceptor, dipole-dipole, and dispersive interactions, the newly synthesized polarizable stationary phases offered unique selectivity for aromatic isomers and substituted benzenes. A slight separation difference between TPP and TFPP was observed. TFPP also exerted excellent selectivity for polycyclic aromatic hydrocarbons, fatty acid esters, and fatty alcohols. Overall, FPP and TFPP demonstrated considerable potential for further applications because of their unique structures and outstanding separation performance. PMID:27139216

  19. Simultaneous determination of organophosphorous insecticides in bean samples by gas chromatography - flame photometric detection

    Directory of Open Access Journals (Sweden)

    Keyller Bastos Borges

    2014-02-01

    Full Text Available The indiscriminate use of organophosphorous pesticides (OPPs in crops may leave residues in food and may cause poisoning in the applicators. A method was developed for the determination of five OPPs in bean samples by Gas Chromatography-Flame Photometric Detection (GC-FPD. Validation parameters comprised linearity between 0.24 and 8.56 μg g-1 (r = 0.9985 for diazinon; 0.23 and 8.14 μg g-1 (r = 0.9959 for methyl parathion; 0.28 and 10.25 μg g-1 (r = 0.9987 for methyl pirimiphos; 0.52 and 18.87 μg g-1 (r = 0.9955 for malathion; 0.86 and 13.67 μg g-1 (r = 0.9919 for ethion. The limits of quantification (equal to those of detection were the lowest rates of ranges mentioned above for each compound. The extraction method showed approximately 95% recovery, with CV% < 15%. Although twenty-eight bean samples obtained in the southern region of the state of Minas Gerais,Brazil, were analyzed, they failed to match any of the OPPs under analysis. The absence of OPPs in the samples could be due to the degradation that occurred between the use of OPPs and bean commercialization, levels below the detection /quantification limits and the non-use of OPPs in bean cultivation.

  20. Determination of 17 β-estradiol in rabbit plasma by gas chromatography with flame ionization detection

    Directory of Open Access Journals (Sweden)

    B Yilmaz

    2012-01-01

    Full Text Available This article describes gas chromatography-flame ionization detection method for determination of 17 β-estradiol in rabbit plasma. 17 β-estradiol and internal standard progesterone were extracted from plasma using liquid-liquid extraction method. Linearity was found between 0.25 and 20 μg/ml (r 2 =0.994 for plasma samples. Intra-day and inter-day precision, expressed as the relative standard deviation were less than 5.5%, and accuracy (relative error was less than 3.5%. The mean recovery of 17 β-estradiol samples was 94.4%. The limits of detection and quantification of method for plasma samples were 0.10 μg/ml and 0.15 μg/ml, respectively. Also, clinically used other 10 drugs were investigated to check for potential interferences and the method was successfully applied to the determination of 17 β-estradiol in New Zealand white rabbits.

  1. Validation of an enantioselective analysis for (l)-pidolic acid by chiral gas chromatography with derivatization.

    Science.gov (United States)

    Salisbury, John J; Li, Mingshu; Boyd, Aisha

    2016-02-20

    A sensitive and rapid analytical method has been validated for the enantiomeric purity determination of l-pidolic acid, a biological lactam and metabolite of glutamic acid commonly found in urine, skin, bones, brain and is available commercially as a food supplement. An efficient, two-step achiral derivatization was implemented which consisted of an alkylation step (using HCl-IPA) followed by an acylation step (using TFAA) of the carboxy and amide functional groups. This allowed detection with high sensitivity using gas chromatography with flame ionization detection. The described procedure employs a CP-Chiralsil-L Val column (25m×0.25mm) at a constant flow rate of 1.5mLmin(-1), a gradient temperature program from 80°C to 160°C and an injector and detector temperature of 250°C. The proposed method was validated according to ICH Q2 standards and included such parameters as specificity, system precision, analyst repeatability, intermediate precision, accuracy, linearity, LOD/LOQ and solution stability. PMID:26710173

  2. Structural investigations of neuromelanin by pyrolysis-gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Pyrolysis combined with gas chromatography and mass spectrometry (Py-GC/MS) was applied for structural investigations of the human substantia nigra neuromelanin. Using synthetic neuromelanins, we have demonstrated that Py-GC/MS is suitable for identification and differentiation of both eumelanin (dopamine-derived) and pheomelanin (cysteinyldopamine-derived) component of the pigment. Structural information on melanin monomers was inferred from their pyrolytic markers. When the human neuromelanin was subjected to pyrolysis, none of the heterocyclic, sulfur-containing markers of pheomelanin component was detected among the thermal degradation products. We have concluded that nigral pigment isolated from normal brain tissue does not contain benzothiazine-type monomers, and that cysteinyldopamine-originated units may be incorporated into the polymer in uncyclized form. The most abundant pyrolysis product was identified as limonene, which indicates that nigral pigment is tightly associated with an isoprenoid-type compound. Pyrolysis in the presence of the methylating reagent allowed identification of high levels of saturated and monounsaturated straight-chain C14-C18 fatty acid species chemically bound to the pigment macromolecule. (author)

  3. Metabolic Fingerprinting of Three Malaysian Ginger (Zingiber officinale Roscoe Using Gas Chromatography-Mass Spectromertry

    Directory of Open Access Journals (Sweden)

    H. J. Mahdi

    2010-01-01

    Full Text Available Problem statement: There is a chemical variation among different ginger cultivars detected by previous studies including the volatile and non-volatile oleo-resins. In this study we try to determine whether these variations are related to a genetic factor rather than environmental or intrinsic factors. Approach: A comprehensive metabolic fingerprinting from the leaves of three micro-propagated ginger cultivars Bukit Tinggi, Tanjung Sepat and Sabah was performed using a Gas Chromatography-Mass Spectrometry (GC-MS. Constituents of the ginger leaves were first extracted and then fractionated into methanolic and chloroform. The samples were subsequently methoximated and silylated prior to GC-MS analysis. Results: By applying this technique, we detected more than 300 compounds (polar and non-polar in total originated from each ginger cultivar. Based on the GC-MS fragmentation, three different classes of metabolites were detected from the ginger cultivars, namely amino acids, carbohydrates and organic acids. A qualitative variation on the type of ginger metabolites was observed, albeit no marked different found in the level of the metabolites. Conclusion: Apparently the chemical variations among the three ginger cultivars were due to genetic effects since almost all other environmental and intrinsic factors were eliminated.

  4. Presence of phthalate esters in intravenous solution evaluated using gas chromatography-mass spectrometry method.

    Science.gov (United States)

    Strac, Ivona Vidić; Pušić, Maja; Gajski, Goran; Garaj-Vrhovac, Vera

    2013-03-01

    Di-(2-ethylhexyl) phthalate (DEHP) is a plasticizer widely used in the production of poly-(vinyl) chloride (PVC) materials. It is a reproductive and developmental toxicant in animals and a suspected endocrine modulator in humans. DEHP is not covalently bound within the PVC molecule, which is why migration into a suitable medium can be expected. Since application of infusion solutions is one of the most common medical treatments, the objective of this study was to determine the migration of phthalates from softened PVC storage bags into infusion solution in different time periods within one year from date of production using a gas chromatography-mass spectrometry method. The measured values of DEHP ranged between 0.22 and 14.00 µg l(-1) , but the unexpected presence of other phthalate esters was also detected. It was concluded that values obtained in infusion solutions match the reference data and represent a minor risk for the patient. The presence of other phthalate esters leads to the conclusion that the pharmacopeic requirement for polymer cleanness was not fully met. Since phthalate esters are among the most extensively used industrial chemicals and are widely distributed in the environment, special precautions and further monitoring should be conducted to minimize any possible health risks. PMID:22034089

  5. The utilisation of two detectors for the determination of water in honey using headspace gas chromatography.

    Science.gov (United States)

    Frink, Lillian A; Armstrong, Daniel W

    2016-08-15

    A headspace gas chromatography (HSGC) method was developed for the determination of water content in honey. This method was shown to work with five different honey varieties which had a range of water from 14-16%. It also utilised two different detectors, the thermal conductivity detector (TCD) and the barrier discharge ionisation detector (BID). This method needs no heating pretreatment step as in the current leading method, (i.e. the measurement of refractive index). The solvent-free procedure negates the possibility of solvent-compound interactions as well as solubility limitations, as is common with Karl Fischer titrations. It was also apparent that the classic loss on drying method consistently and substantially produced results that were lower than the correct values. This approach is shown to be rapid, with an analysis time of 4 min when using the TCD detector and under 3 min when utilising the BID detector. HSGC is feasible for the determination of water due to the new PEG-linked geminal dicationic ionic-liquid-coated GC capillary column. In addition it provides accurate and precise determinations of the water content in honey. When using the sensitive BID detector, other trace volatile compounds are observed as well. PMID:27006209

  6. Headspace Analysis of Philippine Civet Coffee Beans Using Gas Chromatography-Mass Spectrometry and Electronic Nose

    Science.gov (United States)

    Ongo, E.; Sevilla, F.; Antonelli, A.; Sberveglieri, G.; Montevecchi, G.; Sberveglieri, V.; de Paola, E. L.; Concina, I.; Falasconi, M.

    2011-11-01

    Civet coffee, the most expensive and best coffee in the world, is an economically important export product of the Philippines. With a growing threat of food adulteration and counterfeiting, a need for quality authentication is essential to protect the integrity and strong market value of Philippine civet coffee. At present, there is no internationally accepted method of verifying whether a bean is an authentic civet coffee. This study presented a practical and promising approach to identify and establish the headspace qualitative profile of Philippine civet coffee using electronic nose (E-nose) and gas chromatography-mass spectrometry (GC-MS). E-nose analysis revealed that aroma characteristic is one of the most important quality indicators of civet coffee. The findings were supported by GC-MS analysis. Principal component analysis (PCA) exhibited a clearly separated civet coffees from their control beans. The chromatographic fingerprints indicated that civet coffees differed with their control beans in terms of composition and concentration of individual volatile constituents.

  7. Comparison of motor oils using high-temperature gas chromatography-mass spectrometry.

    Science.gov (United States)

    Reardon, Michelle R; Allen, Lance; Bender, Edward C; Boyle, Katherine M

    2007-05-01

    The analysis of motor oils has wide applications in the forensic science field from comparing lubricants transferred between an automobile and a victim or crime scene to differentiating the compositions of plastic explosives. In this study, 40 unused motor oils were analyzed and compared by high-temperature gas chromatography-mass spectrometry to determine the potential for oil individualization. Oil samples were also collected from the crankcase dipsticks of 30 cars. Twenty-six of these oils could be differentiated from each other based on visual comparisons of the unresolved envelope (baseline rise due to incomplete separation) and the resolved hydrocarbons in the raw total ion chromatograms (TICs) and smoothed TIC data. Four of these oils were analyzed as unknowns and were correctly related to the corresponding vehicle. The use of extracted ion profiles (EIPs) was explored as a means to further discriminate between the indistinct samples based on the polycyclic aromatic hydrocarbon (PAH) content. The research discussed in this paper demonstrated that differentiation of motor oils was possible by examining the TIC, smoothed TIC, and EIP data. PMID:17456092

  8. Isotopic fractionation of fentanyl and its deuterated analogues by capillary gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Sera, Shoji; Goromaru, Tsuyoshi [Fukuyama Univ., Hiroshima (Japan)

    1997-12-01

    Isotopic fractionation of fentanyl (FT) and its deuterated analogues by gas chromatography using capillary columns (CBP1 and CBP5) has been investigated. Seven kinds of analogues were labeled with 5 to 19 deuterium atoms at the anilino, propionyl and/or phenylethyl group of FT. The retention times of deuterated FT in CBP1 and CBP5 columns are inversely proportional to the number of labeled deuterium atoms in the molecule. The difference in free enegy changes ({Delta}{Delta}G) had a linear relationship with the number of labeled deuterium atoms, except for labeling at anilino and phenylethyl group. The contribution of a deuterium atom to the {Delta}{Delta}G value was estimated to be 1.13 cal/mol in CBP1 and 1.40 cal/mol in CBP5, respectively. While, its contribution in the propiony group was 2.84 cal/mol in CBP1 and 2.48 cal/mol in CBP5, respectively. An important factor in separation by GC may differences in interactions between the stationary phase of the column with the three dimensional protrusive moiety in the molecule. (author)

  9. Discriminating Hodgdon Pyrodex(®) and Triple Seven(®) using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Routon, Benjamin J; Kocher, Brandon B; Goodpaster, John V

    2011-01-01

    Pyrodex(®) and Triple Seven(®) are black powder substitutes that often find use as fillers in improvised explosive devices, such as pipe bombs. These propellants have essentially the same overall appearance and oxidizers, but different fuels. For example, Pyrodex(®) contains sulfur, sodium benzoate, and dicyandiamide (DCDA), whereas Triple Seven(®) lacks sulfur but also contains 3-nitrobenzoic acid. In this method, intact particles and postblast solid residues were reacted with bis(trimethylsilyl)trifluoroacetamide + 1% trimethylchlorosilane in acetonitrile for 30 min at 60°C. The resultant trimethylsilyl derivatives of the organic fuels were then analyzed by gas chromatography-mass spectrometry. Each derivative was clearly resolved from other components, and high-quality mass spectra were obtained. In addition, characteristic fragments resulting from loss of a methyl radical from the molecular ion (m/z 163 for sulfur, m/z 171 for DCDA, m/z 179 for benzoic acid, and m/z 224 for nitrobenzoic acid) were able to be monitored.

  10. Analysis of volatile compounds of Malaysian Tualang (Koompassia excelsa) honey using gas chromatography mass spectrometry.

    Science.gov (United States)

    Nurul Syazana, M S; Gan, S H; Halim, A S; Shah, Nurul Syazana Mohamad; Gan, Siew Hua; Sukari, Halim Ahmad

    2013-01-01

    The constituents of honey's volatile compounds depend on the nectar source and differ depending on the place of origin. To date, the volatile constituents of Tualang honey have never been investigated. The objective of this study was to analyze the volatile compounds in local Malaysian Tualang honey. A continuous extraction of Tualang honey using five organic solvents was carried out starting from non-polar to polar solvents and the extracted samples were analysed using gas chromatography-mass spectrometry (GC-MS). Overall, 35 volatile compounds were detected. Hydrocarbons constitute 58.5% of the composition of Tualang honey. Other classes of chemical compounds detected included acids, aldehydes, alcohols, ketones, terpenes, furans and a miscellaneous group. Methanol yielded the highest number of extracted compounds such as acids and 5-(Hydroxymethyl) furfural (HMF). This is the first study to describe the volatile compounds in Tualang honey. The use of a simple one tube, stepwise, non-thermal liquid-liquid extraction of honey is a advantageous as it prevents sample loss. Further research to test the clinical benefits of these volatile compounds is recommended.

  11. Study of Thermal Activated CO2 Extraction Processes from Carbonate Apatites Using Gas Chromatography

    Directory of Open Access Journals (Sweden)

    V.N. Kuznetsov

    2015-10-01

    Full Text Available The study of carbonate in the structure of carbonate-containing apatites (CCA is an actual problem due to the similarity of such systems to natural apatites of mammalian bone tissue. The search of the optimal synthesis procedures was also carried out in order to obtain carbonate apatites with the highest rate of carbonate ions incorporation into the apatite structure. The analysis of carbonate-group temperature behavior in apatites of various origin helps to understand their structural and functional roles in biologically relevant apatite materials. The thermal extraction and accumulation of CO2 from biogenic and geological apatites is also of interest for the further carbon isotope analysis with accelerating mass-spectrometry. X-ray diffraction analysis, infrared spectroscopy and scanning electron microscopy as well as self-proposed gas chromatography method with thermo-programmed probe extraction were used for carbonate temperature behavior study. This new method allows determining CO2 concentration released from CCA during annealing. The defined changes in carbonate apatite structure depending on synthesis procedure were observed.

  12. Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Baxter, Douglas C; Faarinen, Mikko; Österlund, Heléne; Rodushkin, Ilia; Christensen, Morten

    2011-09-01

    A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with (198)Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) μg L(-1) could be performed with uncertainty amplification factors levels of 0.14 μg L(-1), 0.35 μg L(-1) and 2.8 μg L(-1), with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.

  13. Metabolic Profiling and Quantification of Neurotransmitters in Mouse Brain by Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Jäger, Christian; Hiller, Karsten; Buttini, Manuel

    2016-01-01

    Metabolites are key mediators of cellular functions, and have emerged as important modulators in a variety of diseases. Recent developments in translational biomedicine have highlighted the importance of not looking at just one disease marker or disease inducing molecule, but at populations thereof to gain a global understanding of cellular function in health and disease. The goal of metabolomics is the systematic identification and quantification of metabolite populations. One of the most pressing issues of our times is the understanding of normal and diseased nervous tissue functions. To ensure high quality data, proper sample processing is crucial. Here, we present a method for the extraction of metabolites from brain tissue, their subsequent preparation for non-targeted gas chromatography-mass spectrometry (GC-MS) measurement, as well as giving some guidelines for processing of raw data. In addition, we present a sensitive screening method for neurotransmitters based on GC-MS in selected ion monitoring mode. The precise multi-analyte detection and quantification of amino acid and monoamine neurotransmitters can be used for further studies such as metabolic modeling. Our protocol can be applied to shed light on nervous tissue function in health, as well as neurodegenerative disease mechanisms and the effect of experimental therapeutics at the metabolic level. © 2016 by John Wiley & Sons, Inc. PMID:27584556

  14. Gas Chromatography/Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometry for Fingerprinting the Macondo Oil Spill.

    Science.gov (United States)

    Lobodin, Vladislav V; Maksimova, Ekaterina V; Rodgers, Ryan P

    2016-07-01

    We report the first application of a new mass spectrometry technique (gas chromatography combined to atmospheric pressure chemical ionization tandem mass spectrometry, GC/APCI-MS/MS) for fingerprinting a crude oil and environmental samples from the largest accidental marine oil spill in history (the Macondo oil spill, the Gulf of Mexico, 2010). The fingerprinting of the oil spill is based on a trace analysis of petroleum biomarkers (steranes, diasteranes, and pentacyclic triterpanes) naturally occurring in crude oil. GC/APCI enables soft ionization of petroleum compounds that form abundant molecular ions without (or little) fragmentation. The ability to operate the instrument simultaneously in several tandem mass spectrometry (MS/MS) modes (e.g., full scan, product ion scan, reaction monitoring) significantly improves structural information content and sensitivity of analysis. For fingerprinting the oil spill, we constructed diagrams and conducted correlation studies that measure the similarity between environmental samples and enable us to differentiate the Macondo oil spill from other sources. PMID:27281271

  15. Measurement of phthalates diesters in food using gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Cariou, Ronan; Larvor, Frédéric; Monteau, Fabrice; Marchand, Philippe; Bichon, Emmanuelle; Dervilly-Pinel, Gaud; Antignac, Jean-Philippe; Le Bizec, Bruno

    2016-04-01

    An analytical strategy dedicated to 4 major phthalate diesters (DiBP, DnBP, BBzP and DEHP) monitoring in food items has been developed and validated according to normalized guidelines. The method has been applied to a wide range of foodstuffs (n=54) to generate first-ever occurrence data at the French level. This method involves separation and detection using gas chromatography coupled to tandem mass spectrometry, in electron ionisation with highly specific selected reaction monitoring, quantification being performed according to the isotope dilution principle. A particular attention has been paid to background contamination management at any stage of the analytical process, from the sampling to the expression of the results. Limits of reporting, defined as statistically different from background contamination, were found to be 2.7, 0.53, 0.18 and 3.4 μg kg(-1), and relative combined uncertainties were finally found to be 7.6%, 12.2%, 12.0% and 14.1%, for DiBP, DnBP, BBzP and DEHP, respectively.

  16. Determination of volatile organic compounds in river water by solid phase extraction and gas chromatography

    Institute of Scientific and Technical Information of China (English)

    M. A. Mottaleb; M. Z. Abedin; M. S. Islam

    2004-01-01

    A simple, rapid, and reproducible method is described employing solid-phase extraction(SPE) using dichloromethane followed by gas chromatography(GC) with flame ionization detection(FID) for determination of volatile organic compound(VOC) from the Buriganga River water of Bangladesh. The method was applied to detect the benzene, toluene, ethylbenzene, xylene and cumene(BTEXC) in the sample collected from the surface or 15 cm depth of water. Two-hundred ml of n-hexane-pretreated and filtered water samples were applied directly to a C18 SPE column. BTEXC were extracted with dichloromethane and average concentrations were obtained as 0.104 to 0.372 (g/ml. The highest concentration of benzene was found as 0.372 (g/ml with a relative standard deviation(RSD) of 6.2%, and cumene was not detected. Factors influencing SPE e.g., adsorbent types, sample load volume, eluting solvent, headspace and temperatures, were investigated. A cartridge containing a C18 adsorbent and using dichloromethane gave better performance for extraction of BTEXC from water.Average recoveries exceeding 90% could be achieved for cumene at 4℃with a 2.7%RSD

  17. Surface-sampling and analysis of TATP by swabbing and gas chromatography/mass spectrometry.

    Science.gov (United States)

    Romolo, Francesco Saverio; Cassioli, Luigi; Grossi, Silvana; Cinelli, Giuseppe; Russo, Mario Vincenzo

    2013-01-10

    The method of sample recovery for trace detection and identification of explosives plays a critical role in several criminal investigations. After bombing, there can be difficulties in sending big objects to a laboratory for analysis. Traces can also be searched for on large surfaces, on hands of suspects or on surfaces where the explosive was placed during preparatory phases (e.g. places where an IED was assembled, vehicles used for transportation, etc.). In this work, triacetone triperoxide (TATP) was synthesized from commercial precursors following reported methods. Several portions of about 6mg of TATP were then spread on different surfaces (e.g. floors, tables, etc.) or used in handling tests. Three different swabbing systems were used: a commercial swab, pre-wetted with propan-2-ol (isopropanol) and water (7:3), dry paper swabs, and cotton swabs wetted with propan-2-ol. Paper and commercial swabs were also used to sample a metal plate, where a small charge of about 4g of TATP was detonated. Swabs were sealed in small glass jars with screw caps and Parafilm(®) M and sent to the laboratory for analysis. Swabs were extracted and analysed several weeks later by gas chromatography/mass spectrometry. All the three systems gave positive results, but wetted swabs collected higher amounts of TATP. The developed procedure showed its suitability for use in real cases, allowing TATP detection in several simulations, including a situation in which people wash their hands after handling the explosive.

  18. Quantification of busulfan in plasma by gas chromatography-mass spectrometry following derivatization with tetrafluorothiophenol.

    Science.gov (United States)

    Quernin, M H; Poonkuzhali, B; Montes, C; Krishnamoorthy, R; Dennison, D; Srivastava, A; Vilmer, E; Chandy, M; Jacqz-Aigrain, E

    1998-05-01

    A specific and highly sensitive method has been developed for the determination of busulfan in plasma by gas chromatography-mass spectrometry using a deuterium-labeled busulfan (busulfan-d8) as internal standard. Plasma containing busulfan and busulfan-d8 were extracted with ethyl acetate and derivatized with 2,3,5,6-tetrafluorothiophenol prior to the monitoring of specific ions. The limit of quantification of the assay was 20 ng/ml and the calibration curve was linear over the range of 10 to 2000 ng/ml of derivatized busulfan. This method was in good agreement with the GC-MS assay using derivatization with sodium iodide and measuring diiodobutane. In addition, a pharmacokinetic study of busulfan was conducted in six children. The apparent oral clearance was 5.7+/-1.9 ml/kg/min and the volume of distribution was 1.0+/-0.4 l/kg and were similar to those previously reported in pediatric patients.

  19. Identification of Floral Scent in Chrysanthemum Cultivars and Wild Relatives by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Hainan Sun

    2015-03-01

    Full Text Available The objective of this study was to identify the major volatile compounds and their relative concentrations in flowers of different chrysanthemum cultivars and their wild relatives. The volatile organic components of fresh flowers were analyzed using a headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry. In total, 193 volatile organic components were detected; the major scent components were monoterpenoids and oxygenated monoterpenoids, which accounted for 68.59%–99.93% of the total volatiles in all tested materials except for Chrysanthemum indicum collected from Huangshan, in which they accounted for only 37.45% of total volatiles. The major volatile compounds were camphor, α-pinene, chrysanthenone, safranal, myrcene, eucalyptol, 2,4,5,6,7,7ab-hexahydro-1H-indene, verbenone, β-phellandrene and camphene. In a hierarchical cluster analysis, 39 accessions of Chrysanthemum and its relatives formed six clusters based on their floral volatile compounds. In a principal component analysis, only spider type flowers were located closely on the score plot. The results of this study provide a basis for breeding chrysanthemum cultivars which desirable floral scents.

  20. Multi-class method for biomonitoring of hair samples using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Martín, Julia; Möder, Monika; Gaudl, Alexander; Alonso, Esteban; Reemtsma, Thorsten

    2015-11-01

    Currently, non-invasive biomonitoring of human exposure to organic pollutants bases upon the analysis mainly of urine and human breast milk. While mostly persistent organic pollutants are the center of interest, the aim of our study was to develop a method for the determination of different chemical classes of emerging pollutants (organophosphorus flame retardants, plastic additives such as phthalates, bisphenol A, insecticides, antimicrobials, preservatives and musk fragrances) in hair by gas chromatography-mass spectrometry. The preferred sample preparation included hydrolysis of the hair with trifluoroacetic acid in methanol followed by a liquid-liquid extraction using hexane/ethyl acetate. The validated method is characterized by recoveries higher than 77 % for most analytes, relative standard deviations below 16 % and limits of detection between 2 pg mg(-1) (HHCB) and 292 pg mg(-1) (propylparaben) using 50 mg of dry hair. After respective blank corrections, bis-(2-ethylhexyl)phthalate (DEHP) and the musk fragrance HHCB were the predominant compounds determined in all hair samples at concentrations between 32 and 59 ng mg(-1) and 0.8-13 ng mg(-1), respectively. The bactericide triclosan and the insect repellent N,N-diethyl-3-methylbenzamide (DEET) were detected in selected hair samples at 2 and 0.8 ng mg(-1), respectively.

  1. Hydrocarbon phenotyping of algal species using pyrolysis-gas chromatography mass spectrometry

    Directory of Open Access Journals (Sweden)

    Kothari Shankar L

    2010-05-01

    Full Text Available Abstract Background Biofuels derived from algae biomass and algae lipids might reduce dependence on fossil fuels. Existing analytical techniques need to facilitate rapid characterization of algal species by phenotyping hydrocarbon-related constituents. Results In this study, we compared the hydrocarbon rich algae Botryococcus braunii against the photoautotrophic model algae Chlamydomonas reinhardtii using pyrolysis-gas chromatography quadrupole mass spectrometry (pyGC-MS. Sequences of up to 48 dried samples can be analyzed using pyGC-MS in an automated manner without any sample preparation. Chromatograms of 30-min run times are sufficient to profile pyrolysis products from C8 to C40 carbon chain length. The freely available software tools AMDIS and SpectConnect enables straightforward data processing. In Botryococcus samples, we identified fatty acids, vitamins, sterols and fatty acid esters and several long chain hydrocarbons. The algae species C. reinhardtii, B. braunii race A and B. braunii race B were readily discriminated using their hydrocarbon phenotypes. Substructure annotation and spectral clustering yielded network graphs of similar components for visual overviews of abundant and minor constituents. Conclusion Pyrolysis-GC-MS facilitates large scale screening of hydrocarbon phenotypes for comparisons of strain differences in algae or impact of altered growth and nutrient conditions.

  2. Using gas chromatography/mass spectroscopy fingerprint analyses to document process and progress of oil degradation

    Energy Technology Data Exchange (ETDEWEB)

    Roques, D.E.; Overton, E.B.; Henry, C.B. [Louisiana State Univ., Baton Rouge, LA (United States)

    1994-07-01

    One of the challenges in testing the effectiveness of bioremediation products is the lack of a standardized testing protocol. One requirement of any such evaluation is baseline and benchmark analyses of the oil and its degradation processes. The method described uses high resolution gas chromatography maw spectroscopy (GC/MS). This method has been adapted from oil fingerprinting techniques used by our group for oil spill response to major spills such as T/V Exxon Valdez and T/V Megaborg. It results in a high degree of chemical and spectral resolution from a single analysis that allows quantification of saturated hydrocarbons, polynuclear aromatic hydrocarbons (PAHs), sulfur heterocycles and selected biomarkers such as hopanes and steranes. High resolution GC/MS and compound specific analyses are a viable and efficient method of analyzing the extent and progress of oil bioremediation and that it should be possible to standardize the method for monitoring the biodegradation of oil. Data are also presented that show increased useful information obtained from this method and suggest possible future uses for this expanded database. 14 refs., 4 figs., 1 tab.

  3. [Determination of residual cyclohexanone in disposable infusion set by gas chromatography].

    Science.gov (United States)

    Zhang, Li; Wen, Yan; He, Tao; Wang, Minzhu; Xu, Pinghua

    2014-09-01

    An effective GC method was established for contents determination of the residual solvent of cyclohexanone in infusion sets for single use. The cyclohexanone in infusion sets for single use products were extracted with circular pump, using ethylalcohol as the extraction solven, then the extract followed by analysis of gas chromatography-tandem mass spectrometry. The method was simple, rapid, sensitive and accurate, Cyclohexanone showed good linearity in the range of (5.5-190.9) μg/mL, the correlation coefficient was 0.999 0, the detection limit (S/N = 3) was 0.133 μg/mL and limits of quantitation (S/N = 10) was 1.33 μg/mL. The spiked average recoveries ranged from 98% to 99%. The relative standard deviations (RSDs) of the method ranged from 1.03% to 1.98%. The method was simple, fast, sensitive and accurate, and may serve as a mass control method for residual cyclohexanone in disposable infusion sets for single use.

  4. Characterization of the surface properties of nitrogen-enriched carbons by inverse gas chromatography methods

    Energy Technology Data Exchange (ETDEWEB)

    Vagner, C.; Finqueneisel, G.; Zimny, T.; Burg, P.; Grzyb, B.; Machnikowski, J.; Weber, J.V. [University of Metz, St. Avold (France)

    2003-07-01

    The characterization of the surface properties of carbonaceous materials by inverse gas chromatography (IGC) techniques is described. The cokes investigated were produced by the co-pyrolysis of a coal-tar pitch (CTP) with different amounts of polyacrylonitrile (PAN) as a possible method to synthesize carbonaceous materials enriched in nitrogen. IGC at infinite dilution and LSER (linear solvation energy relationship) techniques were used to determine the physical and chemical surface properties of the cokes. In general, the surface free energy of adsorption is due to both dispersive and specific interactions. The dispersive component of the surface free energy was determined using n-alkane probes. For the specific component, which is primarily due to acid-base interactions, different polar probes were used. The LSER method was applied to improve our understanding of the adsorption process in terms of molecular interactions. We show that, to characterize dispersive interactions using n-alkanes, the LSER and IGC methods are equivalent. On the other hand, with both methods we find that all the samples present acidic and basic characteristics. However, the sensitivity of the LSER method does not allow one to discriminate between the three samples in terms of specific interactions.

  5. Application of finite inverse gas chromatography in hypromellose acetate succinate-water-acetone systems.

    Science.gov (United States)

    Chiu, Sheng-Wei; Sturm, Derek R; Moser, Justin D; Danner, Ronald P

    2016-09-30

    A modification of a GC was developed to investigate both infinitely dilute and finite concentrations of solvents in polymers. Thermodynamic properties of hypromellose acetate succinate (HPMCAS-L)-acetone-water systems are important for the optimization of spray-drying processes used in pharmaceutical manufacturing of solid dispersion formulations. These properties, at temperatures below the glass transition temperature, were investigated using capillary column inverse gas chromatography (CCIGC). Water was much less soluble in the HPMCAS-L than acetone. Experiments were also conducted at infinitely dilute concentrations of one of the solvents in HPMCAS-L that was already saturated with the other solvent. Overall the partitioning of the water was not significantly affected by the presence of either water or acetone in the polymer. The acetone partition coefficient decreased as either acetone or water was added to the HPMCAS-L. A representation of the HPMCAS-L structure in terms of UNIFAC groups has been developed. With these groups, the UNIFAC-vdw-FV model did a reasonable job of predicting the phase equilibria in the binary and ternary systems. The Flory-Huggins correlation with fitted interaction parameters represented the data well. PMID:27629480

  6. [Identification of Kweichow Moutai liquor by gas chromatography-mass spectrometry fingerprint].

    Science.gov (United States)

    Sun, Qiran; Xiang, Ping; Shen, Baohua; Shen, Min

    2010-09-01

    The fingerprint of Kweichow Moutai liquor was established by gas chromatography-mass spectrometry (GC-MS) and the similarity of fingerprints was evaluated by the fingerprint similarity calculation software designed by Zhejiang University based on included angle cosine. One milliliter of liquor sample was mixed with ten microliter of 2% n-pentyl acetate solution used as internal standard. One microliter of the prepared sample was injected into a GC-MS. The separation was performed on an HP-INNOWAX 19091N-113 capillary column. The precision and repeatability of the method were good as the relative standard deviation (RSD) of intrabatch was less than 5%. A total of 35 characteristic components of Kweichow Moutai liquor were identified. The fingerprints of 38 batches of Kweichow Moutai, 5 Moutai-flavor liquors produced by Kweichow Moutai Company Limited, the same manufacturer as Kweichow Moutai, and 12 other brand liquors were compared in characteristic components and similarity. The results demonstrated that different batches of Kweichow Moutai had good similarity (> or = 0.9), and Kweichow Moutai was differentiated from the liquors of different alcohol contents and flavors, but it was poorly distinguished from the Moutai-flavor liquors by fingerprint similarity calculation software. Therefore, only in combining characteristic components and fingerprint similarity results, Kweichow Moutai can be distinguished from other liquors. The established method offers technical basis for the identification of Kweichow Moutai. PMID:21171278

  7. Multiresidue analysis of environmental pollutants in edible vegetable oils by gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Rui-Ze; Jiang, Jie; Mao, Ting; Zhao, Ya-Song; Lu, Yong

    2016-09-15

    A novel multiresidue determination of polycyclic aromatic hydrocarbons (PAHs), phthalate esters (PAEs) and alkylphenols (APs) in edible vegetable oils was developed. The samples were extracted with hexane-saturated acetonitrile, and after concentration, the extract was directly qualitatively and quantitatively analyzed by gas chromatography-tandem mass spectrometry (GC-MS/MS) with multiple reaction monitoring (MRM) in positive ion mode. The calibration curve displayed good linearity in the range of 2-100μg/L, with correlation coefficients greater than 0.99. The mean recoveries were 70.0-110.8% by analysis of spiked oil, and the relative standard deviations (RSDs) were 2.1-10.2% (n=6), respectively. The limits of detection (LODs) for the 23 PAHs, 17 PAEs and 3 APs were 0.1-1.0μg/kg, 0.1-4.0μg/kg and 1.2-3.0μg/kg, respectively. The established method effectively avoided interference from large amounts of lipids and pigments. It was applied to real sample and shown to be a rapid and reliable alternative for determination and confirmation in routine analysis. PMID:27080878

  8. Vapor pressures and vaporization enthalpy of codlemone by correlation gas chromatography

    International Nuclear Information System (INIS)

    Highlights: • The vaporization enthalpy of codlemone has been evaluated. • The vapor pressure of codlemone has been evaluated from T = (298.15 to Tb) K. • Vapor pressures for the 1-alkanols standards are available from T = (298.15 to 500) K. - Abstract: The vapor pressure and vaporization enthalpy of codlemone (trans, trans 8,10-dodecadien-1-ol), the female sex hormone of the codling moth is evaluated by correlation gas chromatography using a series of saturated primary alcohols as standards. A vaporization enthalpy of (92.3 ± 2.6) kJ · mol−1 and a vapor pressure, p/Pa = (0.083 ± 0.012) were evaluated at T = 298.15 K. An equation for the evaluation of vapor pressure from ambient temperature to boiling has been derived by correlation for codlemone. The calculated boiling temperature of TB = 389 K at p = 267 Pa is within the temperature range reported in the literature. A normal boiling temperature of TB = (549.1 ± 0.1) K is also estimated by extrapolation

  9. Determination of phthalate esters in teas and tea infusions by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Du, Liping; Ma, Lijuan; Qiao, Yang; Lu, Yan; Xiao, Dongguang

    2016-04-15

    Phthalate esters (PAEs), a group of environmental pollutants which are carcinogenic to human body, have been detected in teas. In this work, five PAEs in teas and tea infusions were quantitatively determined by a modified simultaneous distillation extraction (SDE) coupled with gas chromatography-mass spectrometry. After the optimization of SDE, the proposed method afforded a wide range of linearity and high linear regression coefficients with the limits of detection range of 0.24-3.72 μg/kg. The average recoveries were 79.83-116.67% for tea samples and 78.22-101.64% for tea infusions with all the relative standard deviations below 20%. The total content of five PAEs in teas was 1.135-3.734 mg/kg and the total dissolving ratio of five PAEs from tea to infusion was 19.05-28.07% for the selected tea samples. The risk assessment result of all the selected tea samples demonstrated that the population with the habit of drinking tea won't cause risk to human health.

  10. Multiresidue Analysis of 86 Pesticides Using Gas Chromatography Mass Spectrometry: II-Nonleafy Vegetables

    Directory of Open Access Journals (Sweden)

    M. H. EL-Saeid

    2013-01-01

    Full Text Available A total of 1057 samples of fresh vegetables from import and domestic production were analyzed (cold pepper, egg plant, carrot, cucumber, potato, hot pepper, cultivation tomato, squash, beans, okra, onions, cauliflower, and green house tomato. The aim of this study was to investigate pesticide residues in market foods in Riyadh, which have been collected from Riyadh Development Company (Al-Tamer Vegetables Market. Pesticide residues were determined by gas chromatography with mass selective detector (GC-MSD. A multiresidue method was developed and described for simultaneous determination of 86 pesticides commonly used in crop protection. This method used to determine 86 pesticide residues with a broad range of physicochemical properties in fresh vegetables related to organophosphorus (OPP, organochlorines (OCP, pyrethroids, and carbamates mainly used in agriculture. Sample extract was cleaned up by using AOAC method. Pesticide residues above the maximum residue limits (MRL were detected in 15.89% of the total samples (168 from 1057 samples, but 83.90% of the total samples (887 from 1057 samples has no residues or contained pesticide residues at or below MRL. The detected and most frequently found pesticide residues were permethrin (45 times and endosulfan (34 times followed by deltamethrin (27 times. The findings of this study pointed to the following recommendations: the need for a monitoring program for pesticide residues in imported food crops.

  11. Determination of fipronil by solid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Vílchez, J L; Prieto, A; Araujo, L; Navalón, A

    2001-06-01

    A method for the determination of trace amounts of the insecticide fipronil was developed using solid-phase microextraction-gas chromatography-mass spectrometry and selected ion monitoring. Fipronil was extracted with a fused-silica fiber coated with 85 microm polyacrylate. The effects of pH, ionic strength, sample volume, extraction and desorption times as well as the extraction temperature were studied. Lindane was used as an internal standard. The linear concentration range of application was 0.3-100 ng ml(-1) of fipronil, with a relative standard deviation of 9.5% (for a level of 50 ng ml(-1)) and a detection limit of 0.08 ng ml(-1). The method was applied to check the eventual existence of fipronil above this limit in water and soil samples from Granada (Spain) as well as in human urine samples. The method validation was completed with spiked matrix samples. The method can be applied as a monitoring tool for water, soil and urine, in the investigation of environmental and occupational exposure to fipronil.

  12. Artificial neural network prediction of quantitative structure - retention relationships of polycyclic aromatic hydocarbons in gas chromatography

    Directory of Open Access Journals (Sweden)

    SNEZANA SREMAC

    2005-11-01

    Full Text Available A feed-forward artificial neural network (ANN model was used to link molecular structures (boiling points, connectivity indices and molecular weights and retention indices of polycyclic aromatic hydrocarbons (PAHs in linear temperature-programmed gas chromatography. A randomly taken subset of PAH retention data reported by Lee et al. [Anal. Chem. 51 (1979 768], containing retention index data for 30 PAHs, was used to make the ANN model. The prediction ability of the trained ANN was tested on unseen data for 18 PAHs from the same article, as well as on the retention data for 7 PAHs experimentally obtained in this work. In addition, two different data sets with known retention indices taken from the literature were analyzed by the same ANN model. It has been shown that the relative accuracy as the degree of agreement between the measured and the predicted retention indices in all testing sets, for most of the studied PAHs, were within the experimental error margins (±3%.

  13. Fluorescent assay of total serum cholesterol, with use of gas-liquid chromatography to study saponification efficiency.

    Science.gov (United States)

    Majeski, E J; Seltzer, E J; Carter, P L; Howlett, D R; Stuart, J D

    1977-11-01

    We describe a fluorescent determination of total cholesterol in serum for which the accuracy and precision are comparable to that for the method of Abell-Kendall, a method of generally accepted accuracy. By the use of quality reagents and the rigorous exclusion of water, the strong fluorophor that develops on reacting concentrated sulfuric acid with cholesterol can be used to quantitatively determine the total cholesterol in serum. We used gas-liquid chromatography to monitor the extent of saponification of the cholesterol esters, because we found them to have fluorescent efficiencies that differed from that of free cholesterol. Sodium methoxide in methanol/methylene chloride (1/3 by vol) was shown by gas-liquid chromatography to very effectively saponify the cholesterol esters in serum.

  14. Rapid direct analysis to discriminate geographic origin of extra virgin olive oils by flash gas chromatography electronic nose and chemometrics.

    Science.gov (United States)

    Melucci, Dora; Bendini, Alessandra; Tesini, Federica; Barbieri, Sara; Zappi, Alessandro; Vichi, Stefania; Conte, Lanfranco; Gallina Toschi, Tullia

    2016-08-01

    At present, the geographical origin of extra virgin olive oils can be ensured by documented traceability, although chemical analysis may add information that is useful for possible confirmation. This preliminary study investigated the effectiveness of flash gas chromatography electronic nose and multivariate data analysis to perform rapid screening of commercial extra virgin olive oils characterized by a different geographical origin declared in the label. A comparison with solid phase micro extraction coupled to gas chromatography mass spectrometry was also performed. The new method is suitable to verify the geographic origin of extra virgin olive oils based on principal components analysis and discriminant analysis applied to the volatile profile of the headspace as a fingerprint. The selected variables were suitable in discriminating between "100% Italian" and "non-100% Italian" oils. Partial least squares discriminant analysis also allowed prediction of the degree of membership of unknown samples to the classes examined. PMID:26988501

  15. Determination of cholesterol and four phytosterols in foods without derivatization by gas chromatography-tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Yan-Zong Chen

    2015-12-01

    Full Text Available In this study, a method for determination of cholesterol and four phytosterols by gas chromatography coupled with electron impact ionization mode–tandem mass spectrometry without derivatization in general food was developed. The sample was saponified with 7.5% KOH in methanol. After heating on hot plate and reflux for 60 minutes, the saponified portion was extracted with n-hexane/petroleum ether (50:50, v/v. The extracts were evaporated with rotary evaporator and then redissolved with tetrahydrofuran. The tetrahydrofuran layer was transferred into an injection vial and analyzed by gas chromatography on a 30 m VF-5 column. Limit of quantification was 2 mg/kg. Recoveries of cholesterol and four phytosterols from general food were between 91% and 100%.

  16. Quantitative determination of terbutaline and orciprenaline in human plasma by gas chromatography/negative ion chemical ionization/mass spectrometry.

    Science.gov (United States)

    Leis, H J; Gleispach, H; Nitsche, V; Malle, E

    1990-06-01

    A method for the determination of unconjugated terbutaline and orciprenaline in human plasma is described. The assay is based on stable isotope dilution gas chromatography/negative ion chemical ionization/mass spectrometry. An inexpensive and rapid method for preparation of stable isotope labelled analogues as well as their use in quantitative gas chromatography/mass spectrometry is shown. A highly efficient sample work-up procedure with product recoveries of more than 95% is presented. The method developed permits quantitative measurement of terbutaline and orciprenaline in human plasma down to 100 pg ml-1, using 1 ml of sample. Plasma levels of terbutaline after oral administration of 5 mg of terbutaline sulphate were estimated. PMID:2357489

  17. Measurement of pyrethroid, organophosphorus, and carbamate insecticides in human plasma using isotope dilution gas chromatography-high resolution mass spectrometry.

    Science.gov (United States)

    Pérez, José J; Williams, Megan K; Weerasekera, Gayanga; Smith, Kimberly; Whyatt, Robin M; Needham, Larry L; Barr, Dana Boyd

    2010-10-01

    We have developed a gas chromatography-high resolution mass spectrometry method for measuring pyrethroid, organophosphorus, carbamate and fipronil pesticides and the synergist piperonyl butoxide in human plasma. Plasma samples were extracted using solid phase extraction and were then concentrated for injection and analysis using isotope dilution gas chromatography-high resolution mass spectrometry. The limits of detection ranged from 10 to 158 pg/mL with relative recoveries at concentrations near the LODs (e.g., 25 or 250 pg/mL) ranging from 87% to 156% (9 of the 16 compounds were within ±15% of 100%). The extraction recoveries ranged from 20% to 98% and the overall method relative standard deviations were typically less than 20% with some exceptions. Analytical characteristics were determined at 25, 250, and 1000 pg/mL.

  18. Chlorococcalean microalgae Ankistrodesmus convolutes biodiesel characterization with Fourier transform-infrared spectroscopy and gas chromatography mass spectroscopy techniques

    Directory of Open Access Journals (Sweden)

    Swati SONAWANE

    2015-12-01

    Full Text Available The Chlorococcalean microalgae Ankistrodesmus convolutes was found in fresh water Godawari reservoir, Ahmednagar district of Maharashtra State, India. Microalgae are modern biomass for the production of liquid biofuel due to its high solar cultivation efficiency. The collection, harvesting and drying processes were play vital role in converting algal biomass into energy liquid fuel. The oil extraction was the important step for the biodiesel synthesis. The fatty acid methyl ester (FAME synthesis was carried through base catalyzed transesterification method. The product was analyzed by using the hyphened techniques like Fourier Transform-Infrared spectroscopy (FT-IR and Gas Chromatography Mass Spectroscopy (GCMS. FT-IR Spectroscopy was results the ester as functional group of obtained product while the Gas Chromatography Mass Spectroscopy was results the six type of fatty acid methyl ester with different concentration. Ankistrodesmus convolutes biodiesel consist of 46.5% saturated and 49.14% unsaturated FAME.

  19. Detection of 2-eicosanol by gas chromatography-mass spectrometry in sputa from patients with pulmonary mycobacterial infections.

    OpenAIRE

    Alugupalli, S; Olsson, B; Larsson, L.

    1993-01-01

    A total of 96 sputum specimens from patients with suspected or known mycobacterial and nonmycobacterial pulmonary infections were analyzed by gas chromatography-mass spectrometry for the presence of 2-eicosanol. This secondary alcohol was detected in all of the 25 sputum specimens culture positive for Mycobacterium tuberculosis, in 7 of the 9 sputum specimens culture positive for M. avium complex, and in all 3 of the studied sputum specimens associated with M. malmoense. The alcohol was not d...

  20. Determination of Organic Pollutants in Small Samples of Groundwaters by Liquid-Liquid Extraction and Capillary Gas Chromatography

    DEFF Research Database (Denmark)

    Harrison, I.; Leader, R.U.; Higgo, J.J.W.;

    1994-01-01

    A method is presented for the determination of 22 organic compounds in polluted groundwaters. The method includes liquid-liquid extraction of the base/neutral organics from small, alkaline groundwater samples, followed by derivatisation and liquid-liquid extraction of phenolic compounds after...... neutralisation. The extracts were analysed by capillary gas chromatography. Dual detection by flame Ionisation and electron capture was used to reduce analysis time....

  1. Determination of occluded oxygen, nitrogen and hydrogen in zircalloy-4 by vacuum extraction coupled to gas chromatography

    International Nuclear Information System (INIS)

    The technique of vacuum extraction at high temperatures was used for the liberation of gases from zircalloy-4 samples; oxygen, nitrogen and hydrogen were quantitatively analysed by gas chromatography. Two different sets of zircalloy-4 samples were examined. The results for O2, N2 and H2 quantitative analyses satisfy the requirements for the characterization of the zircalloy-4 quality. (C.L.B.)

  2. Application of Gas Chromatography with the Mass Detector (GC-MS) Technique for Detection of Beeswax Adulteration with Paraffin

    OpenAIRE

    Waś Ewa; Szczęsna Teresa; Rybak-Chmielewska Helena

    2015-01-01

    To detect beeswax adulteration with hydrocarbons of alien origin (e.g. paraffin), gas chromatography with mass detector (GC-MS) technique was used. The method has been verified here on beeswax samples with different addition (3, 5, 10, 30, and 50%) of paraffin and validated under the conditions of repeatability and within - laboratory reproducibility. The addition of paraffin to beeswax can already be detected on the basis of an analysis of the chromatograms. The intensity of individual alkan...

  3. Systemic Metabolomic Changes in Blood Samples of Lung Cancer Patients Identified by Gas Chromatography Time-of-Flight Mass Spectrometry

    OpenAIRE

    Suzanne Miyamoto; Taylor, Sandra L.; Barupal, Dinesh K; Ayumu Taguchi; Gert Wohlgemuth; Wikoff, William R.; Yoneda, Ken Y.; Gandara, David R.; Samir M. Hanash; Kyoungmi Kim; Oliver Fiehn

    2015-01-01

    Lung cancer is a leading cause of cancer deaths worldwide. Metabolic alterations in tumor cells coupled with systemic indicators of the host response to tumor development have the potential to yield blood profiles with clinical utility for diagnosis and monitoring of treatment. We report results from two separate studies using gas chromatography time-of-flight mass spectrometry (GC-TOF MS) to profile metabolites in human blood samples that significantly differ from non-small cell lung cancer ...

  4. Determination of Trichlorfon Pesticide Residues in Milk via Gas Chromatography with μ-Electron Capture Detection and GC-MS

    OpenAIRE

    Hem, Lina; Khay, Sathya; Choi, Jeong-Heui; Morgan, E. D.; El-Aty, A.M. Abd; Shim, Jae-Han

    2010-01-01

    The pesticide trichlorfon is readily degraded under experimental conditions to dichlorvos. A method has therefore been developed by which residues of trichlorfon in milk are determined as dichlorvos, using gas chromatography with μ-electron capture detection. The identification of dichlorvos was confirmed by mass spectrometry. Milk was extracted with acetonitrile followed by centrifugation, freezing lipid filtration, and partitioning into dichloromethane. The residue after partitioning of dic...

  5. Gas chromatography mass spectrometry computer analysis of volatile halogenated hydrocarbons in man and his environment--A multimedia environmental study.

    Science.gov (United States)

    Barkley, J; Bunch, J; Bursey, J T; Castillo, N; Cooper, S D; Davis, J M; Erickson, M D; Harris, B S; Kirkpatrick, M; Michael, L C; Parks, S P; Pellizzari, E D; Ray, M; Smith, D; Tomer, K B; Wagner, R; Zweidinger, R A

    1980-04-01

    As part of a study to make a comparative analysis of selected halogenated compounds in man and the environmental media, a quantitative gas chromatography mass spectrometric analysis of the levels of the halogenated compounds found in the breath, blood and urine of an exposed population (Old Love Canal area, Niagara, New York) and their immediate environment (air and water) was undertaken. In addition, levels of halogenated hydrocarbons in air samples taken in the general Buffalo, Niagara Falls area were determined.

  6. Determination of volatile aroma compounds of Ganoderma lucidum by gas chromatography mass spectrometry (HS-GC/MS).

    Science.gov (United States)

    Taşkın, Hatıra; Kafkas, Ebru; Çakıroğlu, Özgün; Büyükalaca, Saadet

    2013-01-01

    This study was conducted at Horticulture Department of Cukurova University, Adana, Turkey during 2010-2011. Fresh sample of Ganoderma lucidum collected from Mersin province of Turkey was used as material. Volatile aroma compounds were performed by Headspace Gas Chromatography (HS-GC/MS). Alcohols, aldehydes, acids, phenol, L-Alanine, d-Alanine, 3Methyl, 2-Butanamine, 2-Propanamine were determined. 1-Octen-3-ol (Alcohol) and 3-methyl butanal (Aldehyde) were identified as major aroma compounds.

  7. Development of a Gas Chromatography-Mass Spectrometry Method for the Quantification of Glucaric Acid Derivatives in Beverage Substrates

    OpenAIRE

    Ana Paula Craig; Fields, Christine C.; Simpson, John V.

    2014-01-01

    A gas chromatography-mass spectrometry (GC-MS) method using the standard addition methodology was developed for the determination of glucuronolactone (GL) and glucuronic acid (DGuA) in four beverages categorized as detoxification, recovery, or energy drinks. The method features a precolumn derivatization step with a combination of BSTFA (N,O-bis(trimethylsilyl)trifluoroacetamide) and TMCS (trimethylchlorosilane) to silylate the analytes. The sample pretreatment required no extraction, filtrat...

  8. Gas chromatography mass spectrometry computer analysis of volatile halogenated hydrocarbons in man and his environment--A multimedia environmental study.

    Science.gov (United States)

    Barkley, J; Bunch, J; Bursey, J T; Castillo, N; Cooper, S D; Davis, J M; Erickson, M D; Harris, B S; Kirkpatrick, M; Michael, L C; Parks, S P; Pellizzari, E D; Ray, M; Smith, D; Tomer, K B; Wagner, R; Zweidinger, R A

    1980-04-01

    As part of a study to make a comparative analysis of selected halogenated compounds in man and the environmental media, a quantitative gas chromatography mass spectrometric analysis of the levels of the halogenated compounds found in the breath, blood and urine of an exposed population (Old Love Canal area, Niagara, New York) and their immediate environment (air and water) was undertaken. In addition, levels of halogenated hydrocarbons in air samples taken in the general Buffalo, Niagara Falls area were determined. PMID:7448328

  9. The Global Volatile Signature of Veal via Solid-phase Microextraction and Gas Chromatography-mass Spectrometry

    OpenAIRE

    Wei, Jinmei; Wan, Kun; Luo, Yuzhu; Zhang, Li

    2014-01-01

    The volatile composition of veal has yet to be reported and is one of the important factors determining meat character and quality. To identify the most important aroma compounds in veal from Holstein bull calves fed one of three diets, samples were subjected to solid-phase microextraction (SPME) combined with gas chromatography-quadrupole mass spectrometry (GC-MS). Most of the important odorants were aldehydes and alcohols. For group A (veal calves fed entirely on milk for 90 d before slaugh...

  10. Determining the amount of Acrylamide in Potato Chips Using Xanthydrol as a Derivative Representative with Gas Chromatography-Mass Spectrometry

    OpenAIRE

    Maryam Zokaei; Marzieh Kamankesh; Saeideh Shojaei; Abdorreza Mohammadi

    2016-01-01

    Background and Objectives: In the production process of foods rich in carbohydrates and some other foods containing precursors of acrylamide formation, there is the possibility of acrylamide creation, which is a mutagen and carcinogen material. This study aims to introduce and optimize a new method for determining acrylamide in potato chips using xanthydrol as a derivative representative with gas chromatography-mass spectrometry. Materials and Methods: Important factors in the derivatizat...

  11. Identification and hazard prediction of tattoo pigments by means of pyrolysis—gas chromatography/mass spectrometry

    OpenAIRE

    Schreiver, Ines; Hutzler, Christoph; Andree, Sarah; Laux, Peter; Luch, Andreas

    2016-01-01

    The implementation of regulation for tattoo ink ingredients across Europe has generated the need for analytical methods suitable to identify prohibited compounds. Common challenges of this subject are the poor solubility and the lack of volatility for most pigments and polymers applied in tattoo inks. Here, we present pyrolysis coupled to online gas chromatography and electron impact ionization mass spectrometry (py-GC/MS) as quick and reliable tool for pigment identification using both purif...

  12. ANALYSIS OF CHEMICAL COMPOUNDS OF AGARWOOD OIL FROM DIFFERENT SPECIES BY GAS CHROMATOGRAPHY MASS SPECTROMETRY (GCMS

    Directory of Open Access Journals (Sweden)

    Yumi Zuhanis Has-Yun Hashim

    2014-05-01

    Full Text Available ABSTRACT: Agarwood oil is a highly prized type of oil due to its unique aroma. The oil is extracted from the fragrant resin found in the agarwood tree (trunk.  The unique aroma and quality of agarwood resin and oil are contributed by the presence of certain chemical compounds. In this work, analysis and comparison of the chemical compounds of agarwood oil from A. malaccensis, A. sub-integra and a mixture of both were conducted.  The essential oils were diluted in hexane (5% prior to gas chromatography mass spectrometry (GCMS analysis performed using Agilent GCMS 7890A coupled with MSD quadrupole detector 5975 C.  Separation of analytes by gas chromatography was carried out using a Hewlett Packard HP-5MS silica capillary column (30 m X 0.25 mm X 0.25 mm. A total of 107 compounds were identified from the three samples of agarwood oils. Fifty-five (55 components were identified in A. malaccensis sample which contributes to the largest portion of the total compounds. About 20% of the compounds identified were aromatic and sesquiterpenes which have been revealed to be the main active compounds of agarwood oils which also give the aroma and pleasant odour of agarwood. Different compositions or profile of chemical components were found in agarwood oils from the two different species. Two compounds were commonly identified in all three samples namely 3-phenyl-2-butanone and alpha-cubebene.  Further studies are needed to refine the results which later can be used to assist detection and authentication of agarwood as well as its scientific-based grading. ABSTRAK: Minyak gaharu merupakan sejenis minyak beraroma unik yang mendapat permintaan tinggi dan mahal. Minyak ini diekstrak daripada resin beraroma yang terbentuk di dalam batang pokok gaharu. Keunikan aroma dan kualiti resin dan minyak gaharu ini bergantung kepada kehadiran bahan kimia tertentu. Penyelidikan ini menjurus kepada analisis dan perbandingan bahan-bahan kimia yang terdapat dalam minyak

  13. Residual solvent determination by head space gas chromatography with flame ionization detector in omeprazole API

    Directory of Open Access Journals (Sweden)

    Saurabh Pandey

    2011-06-01

    Full Text Available Residual solvents in pharmaceutical samples are monitored using gas chromatography with head space. Based on good manufacturing practices, measuring residual solvents is mandatory for the release testing of all active pharmaceutical ingredients (API. The analysis of residual organic solvents (methanol, acetone, cyclohexane, dichloromethane, toluene in Omeprazole, an active pharmaceutical ingredient was investigated. Omeprazole is a potent reversible inhibitor of the gastric proton pump H+/K+-ATPase. The Head space gas chromatography (HSGC method described in this investigation utilized a SPB TM-624, Supelco, 30 m long x 0.25 mm internal diameter, 1.4µm-thick column. Since Omeprazole is a thermally labile compound, the selection of the proper injector temperature is critical to the success of the analysis. The injector temperature was set at 170ºC to prevent degradation. The initial oven temperature was set at 40ºC for 12 min and programmed at a rate of 10ºC min-1 to a final temperature of 220ºC for 5 min. Nitrogen was used as a carrier gas. The sample solvent selected was N,N-dimethylacetamide. The method was validated to be specific, linear, precise, sensitive, rugged and showed excellent recovery.Solventes residuais em amostras farmacêuticas são monitoradas utilizando-se cromatografia a gás "headspace". Com base nas boas práticas de fabricação, a medida de solventes residuais é obrigatória para o teste de liberação de todos os ingredientes farmacêuticos (API. Efetuou-se a análise de solventes orgânicos residuais (metanol, acetona, cicloexano, diclorometano, tolueno em omeprazol, ingrediente farmacêutico ativo. O omeprazol é potente inibidor reversível da bomba de prótons H+/K+-ATPase. A cromatografia a gás "headspace" (HSGC descrita nessa pesquisa utilizou um SPB TM-624, Supelco, de 30 m de comprimento x 0,25 mm de diâmetro interno, e coluna de 1,4 µm de espessura. Considerando-se que o omeprazol é termicamente l

  14. Determination of Organic Volatile Impurities in Herbal Formulations and Extracts by Capillary Gas Chromatography

    Directory of Open Access Journals (Sweden)

    S B Puranik

    2009-03-01

    Full Text Available Summary: Organic volatile impurities (OVIs, residual solvents in herbal formulations and extracts were monitored using gas chromatography (GC with Flame Ionisation detector (FID. As per GMP, measuring residual solvents is mandatory. It is now possible to take advantage of GC equipment with faster temperature ramping capabilities, in combination with shorter capillary GC columns, to achieve considerable gain in efficiency and reduction in analysis time. In the present study Gas chromatographic method for the determination of methanol, ethanol and isopropyl alcohol at residual levels in herbal formulations and extracts was developed using a flame ionization detector and the separation was carried out on BP 624 column (30m X 0.53mm i.d. X 0.25µm coating thickness, using GC 17 A shimadzu, with nitrogen as carrier gas in the split mode by direct injection method. The retention time for standard methanol, ethanol and isopropyl alcohol was found to be 3.72, 5.26 and 6.28 min respectively. The linearity for methanol, ethanol and isopropyl alcohol (IPA was found to be in the range of 10-400µLmL-1 ,10 - 500 µL mL-1 and 1 -240 µLmL-1 respectively. The method was validated according  to ICH guidelines. The method described is simple, sensitive, rugged, reliable and reproducible for  the quantitation of methanol, ethanol and isopropyl  levels from herbal formulations and extracts and their levels are found to be within the ICH limits.Industrial relevance: ICH guidelines have mentioned the limits for solvents according to their toxicity level. They have classified the solvents into four Classes, Class 1 limits 2, 4, 15 ppm for benzene, carbon tetrachloride and 1, 1, 1-trichloro ethane. Class 2 solvents viz; methanol 3000 ppm, Class 3 ethanol and isopropyl alcohol 5000 ppm. Since various solvents have been used for the extraction, granulation, film coating, cleaning and miscellaneous. It is impossible to remove the residual solvents completely; they

  15. A novel fast gas chromatography method for higher time resolution measurements of speciated monoterpenes in air

    Science.gov (United States)

    Jones, C. E.; Kato, S.; Nakashima, Y.; Kajii, Y.

    2014-05-01

    Biogenic emissions supply the largest fraction of non-methane volatile organic compounds (VOC) from the biosphere to the atmospheric boundary layer, and typically comprise a complex mixture of reactive terpenes. Due to this chemical complexity, achieving comprehensive measurements of biogenic VOC (BVOC) in air within a satisfactory time resolution is analytically challenging. To address this, we have developed a novel, fully automated Fast Gas Chromatography (Fast-GC) based technique to provide higher time resolution monitoring of monoterpenes (and selected other C9-C15 terpenes) during plant emission studies and in ambient air. To our knowledge, this is the first study to apply a Fast-GC based separation technique to achieve quantification of terpenes in ambient air. Three chromatography methods have been developed for atmospheric terpene analysis under different sampling scenarios. Each method facilitates chromatographic separation of selected BVOC within a significantly reduced analysis time compared to conventional GC methods, whilst maintaining the ability to quantify individual monoterpene structural isomers. Using this approach, the C9-C15 BVOC composition of single plant emissions may be characterised within a 14.5 min analysis time. Moreover, in-situ quantification of 12 monoterpenes in unpolluted ambient air may be achieved within an 11.7 min chromatographic separation time (increasing to 19.7 min when simultaneous quantification of multiple oxygenated C9-C10 terpenoids is required, and/or when concentrations of anthropogenic VOC are significant). These analysis times potentially allow for a twofold to fivefold increase in measurement frequency compared to conventional GC methods. Here we outline the technical details and analytical capability of this chromatographic approach, and present the first in-situ Fast-GC observations of 6 monoterpenes and the oxygenated BVOC (OBVOC) linalool in ambient air. During this field deployment within a suburban forest

  16. Screening for estrogen residues in calf urine: Comparison of a validated yeast estrogen bioassay and gas chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Nielen, M.W.F.; Bovee, T.F.H.; Heskamp, H.H.; Lasaroms, J.J.P.; Sanders, M.B.; Rhijn, van J.A.; Groot, M.J.; Hoogenboom, L.A.P.

    2006-01-01

    Within the European Union, the control for residues of illegal hormones in food-producing animals is based on urine analysis for a few target analytes using gas chromatography/mass spectrometry and/or liquid chromatography¿tandem mass spectrometry. Recently, we developed a robust yeast bioassay scre

  17. Optically heated ultra-fast-cycling gas chromatography module for separation of direct sampling and online monitoring applications.

    Science.gov (United States)

    Fischer, Michael; Wohlfahrt, Sebastian; Varga, Janos; Matuschek, Georg; Saraji-Bozorgzad, Mohammad R; Denner, Thomas; Walte, Andreas; Zimmermann, Ralf

    2015-09-01

    This work describes an ultrafast-cycling gas chromatography module (fast-GC module) for direct-sampling gas chromatography/mass spectrometry (GC-MS). The sample can be introduced into the fast-GC module using a common GC injector or any GC × GC modulator. The new fast-GC module offers the possibility to conduct a complete temperature cycle within 30 s. Its thermal mass is minimized by using a specially developed home-built fused silica capillary column stack and a halogen lamp for heat generation, both placed inside a gold-coated quartz glass cylinder. A high airflow blower enables rapid cooling. The new device is highly flexible concerning the used separation column, the applied temperature program, and the integration into existing systems. An application of the fast-GC module is shown in this work by thermal analysis coupled to gas chromatography-mass spectrometry (TA-GC-MS). The continuously evolving gases of the TA are modulated by a liquid CO2 modulator. Because of the rapid cycling of the fast-GC module, it is possible to obtain the best separation while maintaining the online character of the TA. Restrictions in separation and retention time shifting, known from isothermal and normal ramped fast-GC systems, are overcome. PMID:26226397

  18. Enhanced resolution of Mentha piperita volatile fraction using a novel medium-polarity ionic liquid gas chromatography stationary phase.

    Science.gov (United States)

    Ragonese, Carla; Sciarrone, Danilo; Grasso, Elisa; Dugo, Paola; Mondello, Luigi

    2016-02-01

    The evaluation of a novel medium-polarity ionic-liquid-based gas chromatography column, SLB-IL60, towards the analysis of a complex essential oil, namely, a peppermint essential oil sample, is reported. The SLB-IL60 30 m column was subjected to bleeding measurements, by means of conventional gas chromatography with mass spectrometry. The SLB-IL60 column was then evaluated in the analysis of pure standard compounds, chosen as typical constituents of peppermint essential oil. Resolution and peak symmetry (expressed as tailing factors at 10% of peak height) were measured and the results were compared to those obtained on the most widely used columns in such an application, namely a medium-polarity [100% poly(ethyleneglycol)] stationary phase, and an apolar 5% diphenyl/95% dimethyl siloxane. The final part of the evaluation was dedicated to the gas chromatography with mass spectrometry analysis of a peppermint essential oil sample and again the data were compared to those obtained on the 100% poly(ethyleneglycol) and the 5% diphenyl/95% dimethyl siloxane phase. Linear retention indices were determined for all the identified components on the ionic liquid capillary.

  19. Quantitative and fingerprinting analysis of Atractylodes rhizome based on gas chromatography with flame ionization detection combined with chemometrics.

    Science.gov (United States)

    Liu, Qiutao; Kong, Dandan; Luo, Jiaoyang; Kong, Weijun; Guo, Weiying; Yang, Meihua

    2016-07-01

    This study assessed the feasibility of gas chromatography with flame ionization detection fingerprinting combined with chemometrics for quality analysis of Atractylodes rhizome. We extracted essential oils from 20 Atractylodes lancea and Atractylodes koreana samples by hydrodistillation. The variation in extraction yields (1.33-4.06%) suggested that contents of the essential oils differed between species. The volatile components (atractylon, atractydin, and atractylenolide I, II, and III) were quantified by gas chromatography with flame ionization detection and confirmed by gas chromatography with mass spectrometry, and the results demonstrated that the number and content of volatile components differed between A. lancea and A. koreana. We then calculated the relative peak areas of common components and similarities of samples by comparing the chromatograms of A. lancea and A. koreana extracts. Also, we employed several chemometric techniques, including similarity analysis, hierarchical clustering analysis, principal component analysis, and partial least-squares discriminate analysis, to analyze the samples. Results were consistent across analytical methods and showed that samples could be separated according to species. Five volatile components in the essential oils were quantified to further validate the results of the multivariate statistical analysis. The method is simple, stable, accurate, and reproducible. Our results provide a foundation for quality control analysis of A. lancea and A. koreana. PMID:27133960

  20. Gas chromatography mass spectrometry analysis and in vitro antibacterial activity of essential oil from Trigonella foenum-graecum

    Institute of Scientific and Technical Information of China (English)

    Moniruzzaman; Shahinuzzaman; Ahsanul Haque; Rahima Khatun; Zahira Yaakob

    2015-01-01

    Objective: To evaluate the antibacterial activity of essential oil from Trigonella foenum-graecum seeds powder, and identify the compounds from the extracted oil. Methods: The seeds powder of Trigonella foenum-graecum was subjected to Clevenger extractor. Seven strains of bacteria were used to test antibacterial activity of the extract. The activity against bacteria was tested by disk diffusion method using Whatman No. 1 filter paper. Gas chromatography mass spectrometry analysis was performed with an Agilent7890/5975B-gas chromatography/mass selective detector. Results: The hydrodistillation of seeds powder yielded 0.285%(v/w) of oil. Disk diffu-sion of the oil showed bactericidal activity against both Gram negative and Gram positive bacteria of tasted strains. The inhibition zone ranged from (8 ± 0) mm to (15.0 ± 0.7) mm depending on microbial strains. Gas chromatography mass spectrometry analysis showed 14 different compounds. The total compounds represented 80.96%of the oil. Conclusions: The antibacterial activity is due to the effects of different biological active compounds present in the extract. Identification of the compounds may help to develop new effective antimicrobial agent(s). Further researches on purification, characterization and toxicology of the active compounds are needed.

  1. Gas chromatography mass spectrometry analysis and in vitro antibacterial activity of essential oil from Trigonella foenum-graecum

    Institute of Scientific and Technical Information of China (English)

    Moniruzzaman; Shahinuzzaman; Ahsanul; Haque; Rahima; Khatun; Zahira; Yaakob

    2015-01-01

    Objective:To evaluate the antibacterial activity of essential oil from Trigonella foenumgraecum seeds powder,and identify the compounds from the extracted oil.Methods:The seeds powder of Trigonella foenum-graecum was subjected to Clevenger extractor.Seven strains of bacteria were used to test antibacterial activity of the extract.The activity against bacteria was tested by disk diffusion method using Whatman No.1filter paper.Gas chromatography mass spectrometry analysis was performed with an Agilent7890/5975B-gas chromatography/mass selective detector.Results:The hydrodistillation of seeds powder yielded 0.285%(v/w)of oil.Disk diffusion of the oil showed bactericidal activity against both Gram negative and Gram positive bacteria of tasted strains.The inhibition zone ranged from(8±0)mm to(15.0±0.7)mm depending on microbial strains.Gas chromatography mass spectrometry analysis showed14 different compounds.The total compounds represented 80.96%of the oil.Conclusions:The antibacterial activity is due to the effects of different biological active compounds present in the extract.Identification of the compounds may help to develop new effective antimicrobial agent(s).Further researches on purification,characterization and toxicology of the active compounds are needed.

  2. Enhanced resolution of Mentha piperita volatile fraction using a novel medium-polarity ionic liquid gas chromatography stationary phase.

    Science.gov (United States)

    Ragonese, Carla; Sciarrone, Danilo; Grasso, Elisa; Dugo, Paola; Mondello, Luigi

    2016-02-01

    The evaluation of a novel medium-polarity ionic-liquid-based gas chromatography column, SLB-IL60, towards the analysis of a complex essential oil, namely, a peppermint essential oil sample, is reported. The SLB-IL60 30 m column was subjected to bleeding measurements, by means of conventional gas chromatography with mass spectrometry. The SLB-IL60 column was then evaluated in the analysis of pure standard compounds, chosen as typical constituents of peppermint essential oil. Resolution and peak symmetry (expressed as tailing factors at 10% of peak height) were measured and the results were compared to those obtained on the most widely used columns in such an application, namely a medium-polarity [100% poly(ethyleneglycol)] stationary phase, and an apolar 5% diphenyl/95% dimethyl siloxane. The final part of the evaluation was dedicated to the gas chromatography with mass spectrometry analysis of a peppermint essential oil sample and again the data were compared to those obtained on the 100% poly(ethyleneglycol) and the 5% diphenyl/95% dimethyl siloxane phase. Linear retention indices were determined for all the identified components on the ionic liquid capillary. PMID:26613675

  3. EPA Method 525.3 - Determination of Semivolatile Organic Chemicals in Drinking Water by Solid Phase Extraction and Capillary Column Gas Chromatography/Mass Spectrometry (GC/MS)

    Science.gov (United States)

    Method 525.3 is an analytical method that uses solid phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) for the identification and quantitation of 125 selected semi-volatile organic chemicals in drinking water.

  4. MEASUREMENT OF PYRETHROID RESIDUES IN ENVIRONMENTAL AND FOOD SAMPLES BY ENHANCED SOLVENT EXTRACTION/SUPERCRITICAL FLUID EXTRACTION COUPLED WITH GAS CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY

    Science.gov (United States)

    The abstract summarizes pyrethorid methods development research. It provides a summary of sample preparation and analytical techniques such as supercritical fluid extraction, enhance solvent extraction, gas chromatography and tandem mass spectrometry.

  5. Gas Chromatography and Mass Spectrometry Measurements and Protocols for Database and Library Development Relating to Organic Species in Support of the Mars Science Laboratory

    Science.gov (United States)

    Misra, P.; Garcia, R.; Mahaffy, P. R.

    2010-04-01

    An organic contaminant database and library has been developed for use with the Sample Analysis at Mars (SAM) instrumentation utilizing laboratory-based Gas Chromatography-Mass Spectrometry measurements of pyrolyzed and baked material samples.

  6. DETECTION OF HIGH MOLECULAR WEIGHT ORGANIC TRACERS IN VEGETATION SMOKE SAMPLES BY HIGH-TEMPERATURE GAS CHROMATOGRAPHY-MASS SPECTROMETRY. (R823990)

    Science.gov (United States)

    High-temperature high-resolution gas chromatography(HTGC) is an established technique for the separation ofcomplex mixtures of high molecular weight (HMW) compoundswhich do not elute when analyzed on conventional GCcolumns. The combination of this technique wit...

  7. Detection of Stimulants and Narcotics by Liquid Chromatography-Tandem Mass Spectrometry and Gas Chromatography-Mass Spectrometry for Sports Doping Control.

    Science.gov (United States)

    Ahrens, Brian D; Kucherova, Yulia; Butch, Anthony W

    2016-01-01

    Sports drug testing laboratories are required to detect several classes of compounds that are prohibited at all times, which include anabolic agents, peptide hormones, growth factors, beta-2 agonists, hormones and metabolic modulators, and diuretics/masking agents. Other classes of compounds such as stimulants, narcotics, cannabinoids, and glucocorticoids are also prohibited, but only when an athlete is in competition. A single class of compounds can contain a large number of prohibited substances and all of the compounds should be detected by the testing procedure. Since there are almost 70 stimulants on the prohibited list it can be a challenge to develop a single screening method that will optimally detect all the compounds. We describe a combined liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) testing method for detection of all the stimulants and narcotics on the World Anti-Doping Agency prohibited list. Urine for LC-MS/MS testing does not require sample pretreatment and is a direct dilute and shoot method. Urine samples for the GC-MS method require a liquid-liquid extraction followed by derivatization with trifluoroacetic anhydride.

  8. Quantitative Analysis of Tetramethylenedisulfotetramine ("Tetramine") Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Owens, J; Hok, S; Alcaraz, A; Koester, C

    2008-11-13

    Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limit of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.

  9. Urinary metabonomics study in a rat model in response to protein-energy malnutrition by using gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Wu, Zeming; Li, Min; Zhao, Chunxia; Zhou, Jia; Chang, Yuwei; Li, Xiang; Gao, Peng; Lu, Xin; Li, Yousheng; Xu, Guowang

    2010-11-01

    Systematic studies were performed on the biological perturbations in metabolic phenotype responding to protein-energy malnutrition through global metabolic profiling analysis, in combination with pattern recognition. The malnutrition rat model was established through five weeks of strict diet restriction, and the metabonome data obtained from gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS) were integrated to approximate the comprehensive metabolic signature. Principal component analysis and orthogonal projection to latent structure analysis were used for the classification of metabolic phenotypes and discovery of differentiating metabolites. The perturbations in the urine profiles of malnourished rats were marked by higher levels of creatine, threitol, pyroglutamic acid, gluconic acid and kynurenic acid, as well as decreased levels of succinic acid, cis-aconitic acid, citric acid, isocitric acid, threonic acid, trimethylglycine, N-methylnicotinic acid and uric acid. The alterations in these metabolites were associated with perturbations in energy metabolism, carbohydrate, amino acid, and fatty acid metabolism, purine metabolism, cofactor and vitamin metabolism, in response to protein and energy malnutrition. Our findings show the integration of GC-MS and LC-MS techniques for untargeted metabolic profiling analysis was promising for nutriology. PMID:20717558

  10. Rapid recognition of irradiated dry-cured ham by on-line coupling of reversed-phase liquid chromatography with gas chromatography and mass spectrometry.

    Science.gov (United States)

    Martínez, R M; Barba, C; Calvo, M M; Santa-María, G; Herraiz, M

    2011-06-01

    The use of on-line coupling of reversed-phase liquid chromatography and gas chromatography (RPLC-GC) with the through oven transfer adsorption desorption (TOTAD) interface and mass spectrometry (MS) was proposed for testing different types of commercial Spanish dry-cured ham for irradiation treatment at various doses (0, 1.5, 2, and 4 kGy). The qualitative analysis of radiation-specific compounds (e.g., n-pentadecane, 1-hexadecene, 1,7-hexadecadiene, n-heptadecane, 8-heptadecene, and 2-dodecylcyclobutanone) can be simultaneously established in a single run with samples that have or have not been irradiated. The overall analysis, which takes less than 100 min, includes a rapid extraction step using a small amount of dichloromethane-methanol (1:1, vol/vol) and anhydrous sodium sulfate, the subsequent fractionation of the sample in the first dimension of the system (RPLC), the transfer of the target fraction to the second dimension, the GC separation, and the MS detection. The calculated limits of detection in ham were lower than 22 ng/g. Repeatability studies provided relative standard deviation values of 0.8 to 13.5%.

  11. [Determination of 28 organochlorine and pyrethroid pesticides in pine nuts using solid-phase extraction and on-line gel permeation chromatography-gas chromatography/mass spectrometry].

    Science.gov (United States)

    Kang, Qinghe; Wu, Yan; Gao, Kaiyang; Li, Zhibin

    2009-03-01

    An analytical method has been developed for the determination of 28 organochlorine pesticides and pyrethroid pesticides in pine nuts. The sample was extracted With acetonitrile-water (4:1, v/v) as the extraction solution by means of high-speed homogenization. The crude extract was purified by an Aluminium-N solid phase extraction column to remove most of the fat and sterols in the sample, then on-line gel permeation chromatography-gas chromatography/ mass spectrometry (GPC-GC/MS) analysis was performed. The recoveries for the most of pesticides in the sample spiked with the standards of 0.05 mg/kg were 70%-120%, and the relative standard deviations were less than 15%. The limits of detection of 28 organochlorine pesti- and pyrethroid pesticides were 0.002-0.05 mg/kg. The linear relationship and the recovery results were satisfactory. The method is rapid, accurate, highly senstive, and can be used for the simultaneous determination of pesticide residues in pine nuts.

  12. Epoxidized soy bean oil migrating from the gaskets of lids into food packed in glass jars. Analysis by on-line liquid chromatography-gas chromatography.

    Science.gov (United States)

    Fankhauser-Noti, Anja; Fiselier, Katell; Biedermann-Brem, Sandra; Grob, Koni

    2005-08-01

    The migration of epoxidized soy bean oil (ESBO) from the gasket in the lids of glass jars into foods, particularly those rich in edible oil, often far exceeds the legal limit (60 mg/kg). ESBO was determined through a methyl ester isomer of diepoxy linoleic acid. Transesterification occurred directly in the homogenized food. From the extracted methyl esters, the diepoxy components were isolated by normal-phase LC and transferred on-line to gas chromatography with flame ionization detection using the on-column interface in the concurrent solvent evaporation mode. The method involves verification elements to ensure the reliability of the results for every sample analyzed. The detection limit is 2-5 mg/kg, depending on the food. Uncertainty of the procedure is below 10%.

  13. Long term monitoring of methane in the atmosphere by multiplex gas chromatography

    Science.gov (United States)

    Valentin, Jose R.; Carle, Glenn C.; Phillips, John B.

    1985-01-01

    Methane is of interest in the study of the Earth's atmosphere because of its implication in the future global warming of the surface. This warming is produced by the absorption of infrared energy by trace gases. It has been estimated that in the next 40 to 50 years, methane could contribute 20 to 25 pct. as much atmospheric warming as that expected from carbon dioxide increases. Studies to examine sources, sinks, and cycles of methane will require analytical methods capable of continuous unattended measurement with temporal resolution of an hour or less for weeks at a time. Gas chromatography (GC) is one of the most practical methods available to conduct the analysis of air, but limitations in this technique still exist which can be alleviated with multiplex GC (MGC). MGC is a technique where many samples are pseudo-randomly introduced to the chromatograph without regard to the length of time required for an analysis. The resulting data must then be reduced using computational methods such as cross correlation. In the technique reported, a tube packed with silver oxide was used at the inlet of the GC column to create concentration pulses of methane in a sample stream of air. By using only one carrier, i.e., ambient air, an effective and accurate method to monitor the variations in concentration of methane in the atmosphere over long periods of time was developed. Methane in ambient air was monitored for an eight day period and an interesting temporal variability was found. This work has shown the utility of a relatively simple MGC for the analysis of a real environmental sample.

  14. Chemical Profile of Sotol Analyzed by Solid Phase Microextraction-Gas Chromatography

    Directory of Open Access Journals (Sweden)

    Heliodoro de la Garza

    2010-01-01

    Full Text Available Problem statement: Sotol is a distilled spirit made from Dasylirion spp., a plant (called sotol that grows in the wilds of Northern Mexico and west Texas and New Mexico. This alcoholic beverage is produced in a similar process to the more common artisanal tequila and mescal. Sotol is also now beginning to achieve international recognition; however there are few commercial examples available, which are elaborated with poor quality and sensorial attributes un-defined. Approach: This is the first study which reported a chemical characterization of the main components of six commercial sotols, establishing the correlations among the samples and determining the similitude levels. Solid Phase Microextraction-Gas Chromatography (SPME-GC was used to analyze the chemical compounds present in the sotols (HaciendaTM, MestenoTM, Coyamito, Los Cuates, un-aged Alacran and rested Alacran. Results: From data obtained of the analysis of main components, a total of 25 chemical compounds were found to be related with six physicochemical characteristics of sotol, explaining 66.1% of the total variance. Rested Alacran and un-aged Alacran sotols were related by the high content of propionic acid, undecanoic acid, acetic acid, buthanol and furfural and by the low contents of phenyl ethanol, decanoic acid and ethyl dodecanoic acid. MestenoTM and Coyamito sotols presented an opposite chemical composition. HaciendaTM sotol contains high concentration of propanol, ethyl acetate, methyl butanol, hexadienal and low levels of ethyl decanoic acid and naftalene, chemical compounds do not found in Los cuates sotol. Conclusion: This study revealed for first time the chemical profile of the sotol demonstrating the necessity to improve the elaboration process of this alcoholic beverage to offer a Mexican product of high quality in the global market.

  15. Chemometric profile of root extracts of Rhodiola imbricata Edgew. with hyphenated gas chromatography mass spectrometric technique.

    Science.gov (United States)

    Tayade, Amol B; Dhar, Priyanka; Kumar, Jatinder; Sharma, Manu; Chauhan, Rajinder S; Chaurasia, Om P; Srivastava, Ravi B

    2013-01-01

    Rhodiola imbricata Edgew. (Rose root or Arctic root or Golden root or Shrolo), belonging to the family Crassulaceae, is an important food crop and medicinal plant in the Indian trans-Himalayan cold desert. Chemometric profile of the n-hexane, chloroform, dichloroethane, ethyl acetate, methanol, and 60% ethanol root extracts of R. imbricata were performed by hyphenated gas chromatography mass spectrometry (GC/MS) technique. GC/MS analysis was carried out using Thermo Finnigan PolarisQ Ion Trap GC/MS MS system comprising of an AS2000 liquid autosampler. Interpretation on mass spectrum of GC/MS was done using the NIST/EPA/NIH Mass Spectral Database, with NIST MS search program v.2.0g. Chemometric profile of root extracts revealed the presence of 63 phyto-chemotypes, among them, 1-pentacosanol; stigmast-5-en-3-ol, (3β,24S); 1-teracosanol; 1-henteracontanol; 17-pentatriacontene; 13-tetradecen-1-ol acetate; methyl tri-butyl ammonium chloride; bis(2-ethylhexyl) phthalate; 7,8-dimethylbenzocyclooctene; ethyl linoleate; 3-methoxy-5-methylphenol; hexadecanoic acid; camphor; 1,3-dimethoxybenzene; thujone; 1,3-benzenediol, 5-pentadecyl; benzenemethanol, 3-hydroxy, 5-methoxy; cholest-4-ene-3,6-dione; dodecanoic acid, 3-hydroxy; octadecane, 1-chloro; ethanone, 1-(4-hydroxyphenyl); α-tocopherol; ascaridole; campesterol; 1-dotriacontane; heptadecane, 9-hexyl were found to be present in major amount. Eventually, in the present study we have found phytosterols, terpenoids, fatty acids, fatty acid esters, alkyl halides, phenols, alcohols, ethers, alkanes, and alkenes as the major group of phyto-chemotypes in the different root extracts of R. imbricata. All these compounds identified by GC/MS analysis were further investigated for their biological activities and it was found that they possess a diverse range of positive pharmacological actions. In future, isolation of individual phyto-chemotypes and subjecting them to biological activity will definitely prove fruitful results in

  16. Systematic analysis of glycerol: colourimetric screening and gas chromatography-mass spectrometric confirmation.

    Science.gov (United States)

    Sardela, Vinícius F; Scalco, Fernanda B; Cavalcante, Karina M; Simoni, Ruth E; Silva, Deyvison R; Pereira, Henrique Marcelo G; de Oliveira, Maria Lúcia L Costa; Aquino Neto, Francisco R

    2015-10-01

    Glycerol is a naturally occurring polyol in the human body, essential for several metabolic processes. It is widely used in the food, pharmaceutical, and medical industries and in clinical practice as a plasma volume expander (PVE). Athletes, however, may use glycerol to mask the presence of forbidden substances or to enhance performance, inclusively through hyperhydration achieved by glycerol ingestion with added fluid. These practices are considered doping, and are prohibited by the World Anti-Doping Agency (WADA). Therefore, glycerol was introduced in the prohibited list. Doping through glycerol ingestion can readily be identified by detection of elevated glycerol concentrations in urine. In this paper, a protocol for the fast detection of glycerol in urine is proposed. It consists of a previous visual colourimetric screening, followed by a quantitative/qualitative confirmation analysis by mass spectrometry. The screening procedure involves a reaction in which polyhydric alcohols are oxidized by periodate to formic acid and formaldehyde, which is detected by the addition of a fuchsin solution. For the subsequent qualitative/quantitative confirmation analysis, a gas chromatography-mass spectrometry based approach with a non-deuterated internal standard and a drying step of only 10 min is proposed. The linear correlation was demonstrated within WADA´s threshold range. The calculated RSD were 2.1% for within-day precision and 2.8% for between-day precision. The uncertainty estimation was calculated, and a value of 2.7% was obtained. The procedure may also be used for the analysis of other polyols in urine, as for example the PVE mannitol. PMID:26112364

  17. Modeling quality of premium spanish red wines from gas chromatography-olfactometry data.

    Science.gov (United States)

    Ferreira, Vicente; San Juan, Felipe; Escudero, Ana; Culleré, Laura; Fernández-Zurbano, Purificación; Saenz-Navajas, M Pilar; Cacho, Juan

    2009-08-26

    The aroma compositions of 25 premium Spanish red wines have been screened by quantitative gas chromatography-olfactometry and have been related to the quality scores of the wines. The study has shown that up to 65 odorants can be present in the aroma profiles of those wines, 32 of which have been detected in less than half of the samples. One new odorant is reported for the first time in wine [(Z)-2-nonenal], and only 11 odorants, most of them weak and infrequent, remain unknown. Quality was not positively correlated with any single compound or with any olfactometric vector built by the summation of odorants with similar odors. However, an olfactometric vector built by the summation of the olfactometric scores of defective odorants, such as 2-methoxy-3,5-dimethylpyrazine, 4-ethylphenol, 3-ethylphenol, 2,4,6-trichloroanisole, and o-cresol was significant and negatively related to quality. Quality could be satisfactorily explained by a simple partial least-squares model (79% explained variance in cross-validation) with just three X-variables: the aforementioned defective vector, a second vector grouping 9 other compounds with negative aroma nuances, and the fruity vector, grouping 15 compounds with fruit-sweet descriptors. This result shows that the quality of these red wines is primarily related to the presence of defective or negative odorants, and secondarily to the presence of a relatively large number of fruit-sweet odorants. Remarkably, only in a few low-quality samples could defective aroma nuances be detected, which suggests that defective and negative odorants exert a strong aroma suppression effect on fruity aroma.

  18. Determination of polycyclic aromatic hydrocarbons [PAHs] in processed meat products using gas chromatography - flame ionization detector.

    Science.gov (United States)

    Olatunji, Olatunde S; Fatoki, Olalekan S; Opeolu, Beatrice O; Ximba, Bhekumusa J

    2014-08-01

    The concentrations of polycyclic aromatic hydrocarbons (PAHs) in smoked, grilled and boiled meats were determined using gas chromatography - flame ionization detector (GC-FID). PAHs in the processed meats were extracted in n-hexane after hydrolysis with methanolic KOH. Clean-up was achieved using solid phase extraction in neutral-Si/basic-Si/acidic-Si/neutral-Si frits. The fractions, benzo[k]fluoranthene (BkP), benzo[a]pyrene (BaP), indeno[123-cd]pyrene (IP) and benzo[ghi]perylene (BghiP) were separated and quantified using GC-FID. The method and instrument limits of detections were 0.1, 0.1, 0.2, 0.3μg/kg and 0.5, 0.5, 1.0, 1.5μg/kg, respectively, for BkP, BaP, IP and BghiP. The method's recovery and precision generally varied between 83.69% and 94.25% with relative standard deviation (RSD) of 3.18-15.60%; and 90.38-96.71% with relative standard deviation (RSD) of 1.82-12.87% respectively. The concentration of BkP, BaP, IP and BghiP in smoked, grilled and boiled meat samples were ranged 0.64-31.54μg/kg, 0.07-7.04μg/kg, 0.09-15.03, 0.51-46.67μg/kg and 0.01-5.11μg/kg, respectively. PMID:24629971

  19. Calculation and verification of blood ethanol measurement uncertainty for headspace gas chromatography.

    Science.gov (United States)

    Sklerov, Jason H; Couper, Fiona J

    2011-09-01

    An estimate was made of the measurement uncertainty for blood ethanol testing by headspace gas chromatography. While uncertainty often focuses on compliance to a single threshold level (0.08 g/100 mL), the existence of multiple thresholds, related to enhanced sentencing, subject age, or commercial vehicle licensure, necessitate the use of an estimate with validity across multiple specification levels. The uncertainty sources, in order of decreasing magnitude, were method reproducibility, linear calibration, recovery, calibrator preparation, reference material, and sample preparation. A large set of reproducibility data was evaluated (n = 15,433) in order to encompass measurement variability across multiple conditions, operators, instruments, concentrations and timeframes. The relative, combined standard uncertainty was calculated as ±2.7%, with an expanded uncertainty of ±8.2% (99.7% level of confidence, k = 3). Bias was separately evaluated through a recovery study using standard reference material from a national metrology institute. The uncertainty estimate was verified through the use of proficiency test (PT) results. Assigned values for PT results and their associated uncertainties were calculated as robust means (x*) and standard deviations (s*) of participant values. Performance scores demonstrated that the uncertainty estimate was appropriate across the full range of PT concentrations (0.010-0.370 g/100 mL). The use of PT data as an empirical estimate of uncertainty was not examined. Until providers of blood ethanol PT samples include details on how an assigned value is obtained along with its uncertainty and traceability, the use of PT data should be restricted to the role of verification of uncertainty estimates.

  20. Perceptual characterization and analysis of aroma mixtures using gas chromatography recomposition-olfactometry.

    Directory of Open Access Journals (Sweden)

    Arielle J Johnson

    Full Text Available This paper describes the design of a new instrumental technique, Gas Chromatography Recomposition-Olfactometry (GC-R, that adapts the reconstitution technique used in flavor chemistry studies by extracting volatiles from a sample by headspace solid-phase microextraction (SPME, separating the extract on a capillary GC column, and recombining individual compounds selectively as they elute off of the column into a mixture for sensory analysis (Figure 1. Using the chromatogram of a mixture as a map, the GC-R instrument allows the operator to "cut apart" and recombine the components of the mixture at will, selecting compounds, peaks, or sections based on retention time to include or exclude in a reconstitution for sensory analysis. Selective recombination is accomplished with the installation of a Deans Switch directly in-line with the column, which directs compounds either to waste or to a cryotrap at the operator's discretion. This enables the creation of, for example, aroma reconstitutions incorporating all of the volatiles in a sample, including instrumentally undetectable compounds as well those present at concentrations below sensory thresholds, thus correcting for the "reconstitution discrepancy" sometimes noted in flavor chemistry studies. Using only flowering lavender (Lavandula angustifola 'Hidcote Blue' as a source for volatiles, we used the instrument to build mixtures of subsets of lavender volatiles in-instrument and characterized their aroma qualities with a sensory panel. We showed evidence of additive, masking, and synergistic effects in these mixtures and of "lavender' aroma character as an emergent property of specific mixtures. This was accomplished without the need for chemical standards, reductive aroma models, or calculation of Odor Activity Values, and is broadly applicable to any aroma or flavor.

  1. [Surface characterization of urushiol-titanium chelate polymers by inverse gas chromatography].

    Science.gov (United States)

    Xu, Yanlian; Lin, Jinhuo; Xia, Jianrong; Hu, Binghuan

    2011-03-01

    Urushiol-titanium chelate polymer (UTP), the reaction product of urushiol with titanium compound, is a special eco-friendly polymer with excellent performances, such as strong acids-resistance, strong alkalis-resistance, salt solution-resistance and several organic solvent-resistance. Inverse gas chromatography (IGC) was used to measure the dispersive component of surface free energy (gamma(s)d) and the Lewis acid-base parameters of UTP in this work. The gamma(s)d and the acid/base characters of UTP' surfaces were estimated by the retention time with different non-polar and polar probes at infinite dilution region. n-Pentane (C5), n-hexane (C6), n-heptane (C7), n-octane (C8) and n-nonane (C9) were chosen as the non-polar probes to characterize the gamma(s)d. Trichloromethane (CHCl3), tetrahydrofuran (THF) and acetone were chosen as polar probes to detect the Lewis acid-base parameters. The specific free energy (deltaG(a)AB) and the enthalpy (deltaH(a)AB) of adsorption corresponding to acid-base surface interactions were determined. By correlating deltaH(a)AB with the donor and acceptor numbers of the probes, the acidic (K(a)) and the basic (K(b)) parameters of the samples were calculated. The results showed that the dispersive components of the free energy of UTP were 37.68, 33.53, 35.92, 24.01 and 31.32 mJ/m2 at 70, 80, 90, 100 and 110 degrees C, respectively. The Lewis acidic number K(a) of UTP was 0.185 3, and the Lewis basic number K(b) was 0.966 2. The results were of great importance to the study of the surface properties and the applications for urushiol-metal chelate polymers.

  2. Polymer-coated fibrous materials as the stationary phase in packed capillary gas chromatography.

    Science.gov (United States)

    Saito, Yoshihiro; Tahara, Ai; Imaizumi, Motohiro; Takeichi, Tsutomu; Wada, Hiroo; Jinno, Kiyokatsu

    2003-10-15

    Synthetic polymer filaments have been introduced as the support material in packed capillary gas chromatography (GC). The filaments of the heat-resistant polymers, Zylon, Kevlar, Nomex, and Technora, were longitudinally packed into a short fused-silica capillary, followed by the conventional coating process for open-tubular GC columns. The separation of several test mixtures such as n-alkylbenzenes and n-alkanes was carried out with these polymer-coated fiber-packed capillary columns. With the coating by various polymeric materials on the surface of these filaments, the retentivity was significantly improved over the parent fiber-packed column (without polymer coating) as well as a conventional open-tubular capillary of the same length. The results demonstrated a good combination of Zylon as the support and poly(dimethylsiloxane)-based materials as the coating liquid-phase for the successful GC separation of n-alkanes and polycyclic aromatic hydrocarbons (PAHs), while successful applications for other separations such as poly(ethylene glycol) coating for the separation of alcohols were also obtained. From the results it has been suggested that the selectivity of the fiber-packed column could be tuned by selecting different coating materials, indicating the promising possibility for a novel usage of fine fibrous polymers as the support material that can be combined with newly synthesized coating materials specially designed for particular separations. Taking advantage of good thermal stability of the fibers, the column temperature could be elevated to higher than 350 degrees C with the combination of a short metallic capillary.

  3. Urine Mescaline Screening With a Biochip Array Immunoassay and Quantification by Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Battal, Dilek; Barnes, Allan J; Castaneto, Marisol S; Martin, Thomas M; Klette, Kevin L; Huestis, Marilyn A

    2015-12-01

    Mescaline, the primary psychoactive chemical in peyote cactus, has been consumed for thousands of years in ancient religious ceremonies. The US military wanted to determine if mescaline intake was a problem for personnel readiness. Twenty thousand seventeen urine specimens negative for cannabinoids, cocaine, opiates, and amphetamines were tested for mescaline with the Randox Drugs of Abuse V (DOA-V) biochip array immunoassay at the manufacturer's recommended cutoff of 6 mcg/L. A sensitive and specific method for mescaline quantification in urine was developed and fully validated. Extracted analytes were derivatized with pentafluoropropionic anhydride and pentafluoropropanol and quantified by gas chromatography-mass spectrometry (GC/MS) with electron impact ionization. Standard curves, using linear least squares regression with 1/x weighting, were linear from 1 to 250 mcg/L with coefficients of determination >0.994. Intra- and inter-assay imprecision was 90.4%. Mean extraction efficiencies were >92.0% across the linear range. This fully validated method was applied for the confirmation of urinary mescaline in 526 presumptive-positive specimens and 198 randomly selected presumptive-negative specimens at the manufacturer's 6 mcg/L cutoff. No specimen confirmed positive at the GC/MS limit of quantification of 1 mcg/L. Results indicated that during this time frame, there was insufficient mescaline drug use in the military to warrant routine screening in the drug testing program. However, mescaline stability, although assessed, could have contributed to lower prevalence. We also present a validated GC/MS method for mescaline quantification in urine for reliable confirmation of suspected mescaline intake.

  4. [Characterization of surface properties of 1-allyl-3-methylimidazolium chloride ionic liquid by inverse gas chromatography].

    Science.gov (United States)

    Chen, Yali; Wang, Qiang; Deng, Lishuang; Zhang, Zhengfang; Tang, Jun

    2013-02-01

    The determination of the dispersive component of surface free energies (gamma(s)d) at different temperatures and Lewis acid-base parameters of 1-allyl-3-methylimidazolium chloride ionic liquid ([AMIM]Cl) were investigated by means of inverse gas chromatography (IGC). Four n-alkanes, including n-hexane (C6), n-heptane (C7), n-octane (C8) and n-nonane (C9), were chosen as the apolar probes to characterize the dispersive component of the surface free energies at 343.15, 353.15, 363.15 and 373.15 K, respectively; and dichloromethane (DCM), trichloromethane (TCM), tetrahydrofuran (THF), ethyl acetate (EtAc), acetone (Acet) as the polar probes to estimate the Lewis acid-base parameters to judge the interactions between [AMIM] Cl and the solvents. The IGC characterizations encompassed the adsorption thermodynamic parameters to acid-base surface interactions, including the standard enthalpy (deltaHa(s)) and the free energy change of adsorption (deltaGa(s)) at different temperatures. The results showed that the Lewis acid parameter Ka of [AMIM] Cl was 0.34, and the base parameter Kb was 1.68, which indicated it was Lewis amphoteric with predominantly basic character. Furthermore, the free energy of adsorption deltaGa(s) was also figured out. It was found that the gamma(s)d of the [AMIM] Cl were 52.26, 50.82, 46.08 and 42.05 mJ/m2 at 343.15, 353.15, 363.15 and 373.15 K, respectively. The results are of great importance to the study of the surface properties and the application of ionic liquid.

  5. Magnetically responsive polycaprolactone nanoparticles for progesterone screening in biological and environmental samples using gas chromatography.

    Science.gov (United States)

    Es'haghi, Zarrin; Nezhadali, Azizollah; Khatibi, Aram-Dokht

    2016-08-01

    A new Fe3O4/poly(є-caprolactone) (PCL) magnetite nanocomposite was fabricated and used as a sorbent for magnetically mediated PCL microspheres solid-phase extraction (MM-PCL-SPE) followed by gas chromatography-flame ionization detection (GC-FID) for monitoring of progesterone (PGN) hormone in biological and environmental matrices, namely blood serum, tap water, urine, and hospital wastewater. The nanomagnetite core of the sorbent was synthesized by a co-precipitation method. Magnetic nanoparticles (MNPs) were then microencapsulated with PCL microspheres using emulsion polymerization. The nanocomposite was characterized by scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR). The magnetite sorbent can be effectively dispersed in aqueous solution and attracted to an external magnetic field. The MM-PCL-SPE process for PGN assay involved (a) dispersion of the sorbent in the donor phase aqueous solution with sonication, (b) exposure to a magnetic field to collect sorbent that had adsorbed the analyte, and (c) solvent desorption of extracted PGN for GC-FID analysis. The work demonstrates the usefulness of MM-PCL-SPE in the rapid and sensitive monitoring of trace amounts of PGN in real samples. The limit of detection (LOD) and limit of quantification (LOQ) were 1.00 and 3.30 ng/mL, respectively. The relative recoveries in real samples were adequate. Linearity was observed over a wide range of 2.2-10,000.0 ng/mL in aqueous media and urine and 0.01-70.0 μg/mL in blood serum. Graphical Abstract In this research new Fe3O4/poly(є-caprolactone) (PCL) magnetite microspheres were developed as an efficient sorbent for solid-phase extraction of progesterone hormone in biological and environmental matrices. PMID:27299775

  6. A procedure for comprehensive two-dimensional gas chromatography retention time locked dual detection.

    Science.gov (United States)

    Mommers, John; Ritzen, Erik; Dutriez, Thomas; van der Wal, Sjoerd

    2016-08-26

    In this paper, a novel, and easy to perform, retention time locking procedure for locking primary and secondary retention times of detector signals in comprehensive two-dimensional gas chromatography (GCxGC) dual-detection is proposed and its advantages are demonstrated and discussed. The dual detection retention time locking procedure is a 2-step process for a GCxGC system in which the effluent of the primary column is split, by using a pressure regulated splitter, towards the GCxGC modulator using two identical secondary GC columns of which one is installed in the main GC oven and the other is installed in a secondary GC oven. The first step of the locking procedure is to minimize the secondary retention time difference between both detectors of a compound, which has a retention factor (k) close to 0. This is done by stepwise altering the effective secondary column length, simply by sliding the secondary column, which is installed in the main oven, forwards or backwards through the modulator. The second step is to minimize the secondary retention time difference of a compound which has a significant retention in both dimensions. This is done by stepwise altering the secondary oven temperature rate. This locking procedure was successfully demonstrated for the analysis of a diesel sample by GCxGC coupled to a time of flight mass spectrometer (TOFMS) and a nitrogen chemiluminescence detector (NCD) and by GCxGC coupled to a TOFMS and a flame ionization detector (FID). For all compounds the average absolute secondary retention time differences between the NCD or the FID and the TOFMS detectors were 0.03, and 0.07s, respectively, which are significantly less than the average peak widths at half heights, which was 0.2s. PMID:27466154

  7. Metabolomic Analysis of Gingival Crevicular Fluid Using Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Ozeki, Miho; Nozaki, Takenori; Aoki, Jun; Bamba, Takeshi; Jensen, Kirk R.; Murakami, Shinya; Toyoda, Michisato

    2016-01-01

    Periodontitis is one of the most prevalent threats to oral health as the most common cause of tooth loss. In order to perform effective treatment, a clinical test that detect sites where disease activity is high and predicts periodontal tissue destruction is strongly desired, however, it is still difficult to prognose the periodontal tissue breakdown on the basis of conventional methods. The aim of this study is to examine the usefulness of gas chromatography/mass spectrometry (GC/MS), which could eventually be used for on-site analysis of metabolites in gingival crevicular fluid (GCF) in order to objectively diagnose periodontitis at a molecular level. GCF samples were collected from two diseased sites (one site with a moderate pocket and another site with a deep pocket) from each patient and from clinically healthy sites of volunteers. Nineteen metabolites were identified using GC/MS. Total ion current chromatograms showed broad differences in metabolite peak patterns between GCF samples obtained from healthy sites, moderate-pocket sites, and deep-pocket sites. The intensity difference of some metabolites was significant at sites with deep pockets compared to healthy sites. Additionally, metabolite intensities at moderate-pocket sites showed an intermediate profile between the severely diseased sites and healthy sites, which suggested that periodontitis progression could be observed with a changing metabolite profile. Principal component analysis confirmed these observations by clearly delineating healthy sites and sites with deep pockets. These results suggest that metabolomic analysis of GCF could be useful for prediction and diagnosis of periodontal disease in a single visit from a patient and provides the groundwork for establishing a new, on-site diagnostic method for periodontitis. PMID:27446770

  8. Systematic analysis of glycerol: colourimetric screening and gas chromatography-mass spectrometric confirmation.

    Science.gov (United States)

    Sardela, Vinícius F; Scalco, Fernanda B; Cavalcante, Karina M; Simoni, Ruth E; Silva, Deyvison R; Pereira, Henrique Marcelo G; de Oliveira, Maria Lúcia L Costa; Aquino Neto, Francisco R

    2015-10-01

    Glycerol is a naturally occurring polyol in the human body, essential for several metabolic processes. It is widely used in the food, pharmaceutical, and medical industries and in clinical practice as a plasma volume expander (PVE). Athletes, however, may use glycerol to mask the presence of forbidden substances or to enhance performance, inclusively through hyperhydration achieved by glycerol ingestion with added fluid. These practices are considered doping, and are prohibited by the World Anti-Doping Agency (WADA). Therefore, glycerol was introduced in the prohibited list. Doping through glycerol ingestion can readily be identified by detection of elevated glycerol concentrations in urine. In this paper, a protocol for the fast detection of glycerol in urine is proposed. It consists of a previous visual colourimetric screening, followed by a quantitative/qualitative confirmation analysis by mass spectrometry. The screening procedure involves a reaction in which polyhydric alcohols are oxidized by periodate to formic acid and formaldehyde, which is detected by the addition of a fuchsin solution. For the subsequent qualitative/quantitative confirmation analysis, a gas chromatography-mass spectrometry based approach with a non-deuterated internal standard and a drying step of only 10 min is proposed. The linear correlation was demonstrated within WADA´s threshold range. The calculated RSD were 2.1% for within-day precision and 2.8% for between-day precision. The uncertainty estimation was calculated, and a value of 2.7% was obtained. The procedure may also be used for the analysis of other polyols in urine, as for example the PVE mannitol.

  9. Polymer-coated fibrous materials as the stationary phase in packed capillary gas chromatography.

    Science.gov (United States)

    Saito, Yoshihiro; Tahara, Ai; Imaizumi, Motohiro; Takeichi, Tsutomu; Wada, Hiroo; Jinno, Kiyokatsu

    2003-10-15

    Synthetic polymer filaments have been introduced as the support material in packed capillary gas chromatography (GC). The filaments of the heat-resistant polymers, Zylon, Kevlar, Nomex, and Technora, were longitudinally packed into a short fused-silica capillary, followed by the conventional coating process for open-tubular GC columns. The separation of several test mixtures such as n-alkylbenzenes and n-alkanes was carried out with these polymer-coated fiber-packed capillary columns. With the coating by various polymeric materials on the surface of these filaments, the retentivity was significantly improved over the parent fiber-packed column (without polymer coating) as well as a conventional open-tubular capillary of the same length. The results demonstrated a good combination of Zylon as the support and poly(dimethylsiloxane)-based materials as the coating liquid-phase for the successful GC separation of n-alkanes and polycyclic aromatic hydrocarbons (PAHs), while successful applications for other separations such as poly(ethylene glycol) coating for the separation of alcohols were also obtained. From the results it has been suggested that the selectivity of the fiber-packed column could be tuned by selecting different coating materials, indicating the promising possibility for a novel usage of fine fibrous polymers as the support material that can be combined with newly synthesized coating materials specially designed for particular separations. Taking advantage of good thermal stability of the fibers, the column temperature could be elevated to higher than 350 degrees C with the combination of a short metallic capillary. PMID:14710834

  10. Analysis of 23 polycyclic aromatic hydrocarbons in smokeless tobacco by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Stepanov, Irina; Villalta, Peter W; Knezevich, Aleksandar; Jensen, Joni; Hatsukami, Dorothy; Hecht, Stephen S

    2010-01-01

    Smokeless tobacco contains 28 known carcinogens and causes precancerous oral lesions and oral and pancreatic cancer. A recent study conducted by our research team identified eight different polycyclic aromatic hydrocarbons (PAHs) in U.S. moist snuff, encouraging further investigations of this group of toxicants and carcinogens in smokeless tobacco products. In this study, we developed a gas chromatography-mass spectrometry method that allows simultaneous analysis of 23 various PAHs in smokeless tobacco after a simple two-step extraction and purification procedure. The method produced coefficients of variation under 10% for most PAHs. The limits of quantitation for different PAHs varied between 0.3 and 11 ng/g tobacco, starting with a 300 mg sample. The recovery of the stable isotope-labeled internal standards averaged 87%. The method was applied to analysis of 23 moist snuff samples that included various flavors of the most popular U.S. moist snuff brands, as well as 17 samples representing the currently marketed brands of spit-free tobacco pouches, a relatively new type of smokeless tobacco. The sum of all detected PAHs in conventional moist snuff averaged 11.6 (+/-3.7) microg/g dry weight; 20% of this amount was comprised of carcinogenic PAHs. The levels of PAHs in new spit-free tobacco products were much lower than those in moist snuff; the sum of all detected PAHs averaged 1.3 (+/-0.28) microg/g dry weight. Our findings render PAHs one of the most prevalent groups of carcinogens in smokeless tobacco. Urgent measures are required from the U.S. tobacco industry to modify manufacturing processes so that the levels of these toxicants and carcinogens in U.S. moist snuff are greatly reduced.

  11. Determination of thermodynamic properties of poly(cyclohexyl methacrylate)by inverse gas chromatography

    Institute of Scientific and Technical Information of China (English)

    Ismet KAYA; Cigdem Yigit PALA

    2014-01-01

    In this work,some thermodynamic properties of poly( cyclohexyl methacrylate)were studied by inverse gas chromatography( IGC). For this purpose,the polymeric substance was coated on Chromosorb W and which was filled into a glass column. The retention times(tr)of the probes were determined from the interactions of poly(cyclohexyl methacrylate)with n-pentane,n-hexane,n-heptane,n-octane,n-decane, methanol,ethanol,2-propanol,butanol,acetone,ethyl methyl ketone,benzene,toluene and o-xylene by IGC technique. Then,the specific volume(V0g)was determined for each probe molecule. By using(1/T;lnV0g) graphics,the glass transition temperature of poly( cyclohexyl methacrylate)was found to be 373 K. The adsorp-tion heat under the glass transition temperature(ΔH a ),and partial molar heat of sorption above the glass tran-sition(ΔHS1 ),partial molar free energy of sorption(ΔGS1 )and partial molar entropy of sorption(ΔSS1 )belong-ing to sorption for every probe were calculated. The partial molar heat of mixing at infinite dilution(ΔH∞1 ), partial molar free energy of mixing at infinite dilution(ΔG∞1 ),Flory-Huggins interaction parameter(χ∞12 )and weight fraction activity coefficient(a1/w1)∞ values of polymer-solute systems were calculated at different col-umn temperatures. The solubility parameters(δ2 )of the polymer were obtained by IGC technique.

  12. An empirical Bayes model using a competition score for metabolite identification in gas chromatography mass spectrometry

    Directory of Open Access Journals (Sweden)

    Kim Seongho

    2011-10-01

    Full Text Available Abstract Background Mass spectrometry (MS based metabolite profiling has been increasingly popular for scientific and biomedical studies, primarily due to recent technological development such as comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GCxGC/TOF-MS. Nevertheless, the identifications of metabolites from complex samples are subject to errors. Statistical/computational approaches to improve the accuracy of the identifications and false positive estimate are in great need. We propose an empirical Bayes model which accounts for a competing score in addition to the similarity score to tackle this problem. The competition score characterizes the propensity of a candidate metabolite of being matched to some spectrum based on the metabolite's similarity score with other spectra in the library searched against. The competition score allows the model to properly assess the evidence on the presence/absence status of a metabolite based on whether or not the metabolite is matched to some sample spectrum. Results With a mixture of metabolite standards, we demonstrated that our method has better identification accuracy than other four existing methods. Moreover, our method has reliable false discovery rate estimate. We also applied our method to the data collected from the plasma of a rat and identified some metabolites from the plasma under the control of false discovery rate. Conclusions We developed an empirical Bayes model for metabolite identification and validated the method through a mixture of metabolite standards and rat plasma. The results show that our hierarchical model improves identification accuracy as compared with methods that do not structurally model the involved variables. The improvement in identification accuracy is likely to facilitate downstream analysis such as peak alignment and biomarker identification. Raw data and result matrices can be found at http

  13. Metabolomic Analysis of Gingival Crevicular Fluid Using Gas Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Ozeki, Miho; Nozaki, Takenori; Aoki, Jun; Bamba, Takeshi; Jensen, Kirk R; Murakami, Shinya; Toyoda, Michisato

    2016-01-01

    Periodontitis is one of the most prevalent threats to oral health as the most common cause of tooth loss. In order to perform effective treatment, a clinical test that detect sites where disease activity is high and predicts periodontal tissue destruction is strongly desired, however, it is still difficult to prognose the periodontal tissue breakdown on the basis of conventional methods. The aim of this study is to examine the usefulness of gas chromatography/mass spectrometry (GC/MS), which could eventually be used for on-site analysis of metabolites in gingival crevicular fluid (GCF) in order to objectively diagnose periodontitis at a molecular level. GCF samples were collected from two diseased sites (one site with a moderate pocket and another site with a deep pocket) from each patient and from clinically healthy sites of volunteers. Nineteen metabolites were identified using GC/MS. Total ion current chromatograms showed broad differences in metabolite peak patterns between GCF samples obtained from healthy sites, moderate-pocket sites, and deep-pocket sites. The intensity difference of some metabolites was significant at sites with deep pockets compared to healthy sites. Additionally, metabolite intensities at moderate-pocket sites showed an intermediate profile between the severely diseased sites and healthy sites, which suggested that periodontitis progression could be observed with a changing metabolite profile. Principal component analysis confirmed these observations by clearly delineating healthy sites and sites with deep pockets. These results suggest that metabolomic analysis of GCF could be useful for prediction and diagnosis of periodontal disease in a single visit from a patient and provides the groundwork for establishing a new, on-site diagnostic method for periodontitis. PMID:27446770

  14. Gas chromatography/mass spectrometry based component profiling and quality prediction for Japanese sake.

    Science.gov (United States)

    Mimura, Natsuki; Isogai, Atsuko; Iwashita, Kazuhiro; Bamba, Takeshi; Fukusaki, Eiichiro

    2014-10-01

    Sake is a Japanese traditional alcoholic beverage, which is produced by simultaneous saccharification and alcohol fermentation of polished and steamed rice by Aspergillus oryzae and Saccharomyces cerevisiae. About 300 compounds have been identified in sake, and the contribution of individual components to the sake flavor has been examined at the same time. However, only a few compounds could explain the characteristics alone and most of the attributes still remain unclear. The purpose of this study was to examine the relationship between the component profile and the attributes of sake. Gas chromatography coupled with mass spectrometry (GC/MS)-based non-targeted analysis was employed to obtain the low molecular weight component profile of Japanese sake including both nonvolatile and volatile compounds. Sake attributes and overall quality were assessed by analytical descriptive sensory test and the prediction model of the sensory score from the component profile was constructed by means of orthogonal projections to latent structures (OPLS) regression analysis. Our results showed that 12 sake attributes [ginjo-ka (aroma of premium ginjo sake), grassy/aldehydic odor, sweet aroma/caramel/burnt odor, sulfury odor, sour taste, umami, bitter taste, body, amakara (dryness), aftertaste, pungent/smoothness and appearance] and overall quality were accurately explained by component profiles. In addition, we were able to select statistically significant components according to variable importance on projection (VIP). Our methodology clarified the correlation between sake attribute and 200 low molecular components and presented the importance of each component thus, providing new insights to the flavor study of sake. PMID:25060729

  15. Experimental study of the quantitative precision for valve-based comprehensive two-dimensional gas chromatography.

    Science.gov (United States)

    Siegler, W Christopher; Fitz, Brian D; Hoggard, Jamin C; Synovec, Robert E

    2011-07-01

    For complex sample analysis, there is a need for multidimensional chromatographic instrumentation to be able to separate more compounds, often in shorter time frames. This has led to the development of comprehensive two-dimensional chromatographic instrumentation, such as comprehensive two-dimensional gas chromatography (GC × GC). Lately, much of the focus in this field has been on decreasing peak widths and, therefore, increasing peak capacity and peak capacity production. All of these advancements make it possible to analyze more compounds in a shorter amount of time, but the data still need to remain quantitative to address the needs of most applications. In this report, the relationship among the modulation ratio (M(R)), peak sampling phase (φ), retention time variation (Δt(R)), and how these parameters relate to quantitative analysis precision via the relative standard deviation (RSD) was studied experimentally using a valve-based GC × GC instrument. A wide range of the number of modulations across the first dimension peak width, that is, a M(R) range from ~1 to 10, was examined through maintaining an average first dimension peak width at the base, (1)w(b) of ~3 s and varying the second dimension separation run time from 300 to 2900 ms. An average RSD of 2.1% was experimentally observed at an average M(R) of 2, with a corresponding peak capacity production of ~1200 peaks/min possible. Below this M(R) the RSD quickly increased. In a long-term study of the quantitative precision at a M(R) of 2.5, using 126 replicate injections of a test mixture spanning ~35 h, the RSD averaged 3.0%. The findings have significant implications for optimizing peak capacity production by allowing the use of the longest second dimension run time, while maintaining quantitative precision. PMID:21627311

  16. Chemometric profile of root extracts of Rhodiola imbricata Edgew. with hyphenated gas chromatography mass spectrometric technique.

    Directory of Open Access Journals (Sweden)

    Amol B Tayade

    Full Text Available Rhodiola imbricata Edgew. (Rose root or Arctic root or Golden root or Shrolo, belonging to the family Crassulaceae, is an important food crop and medicinal plant in the Indian trans-Himalayan cold desert. Chemometric profile of the n-hexane, chloroform, dichloroethane, ethyl acetate, methanol, and 60% ethanol root extracts of R. imbricata were performed by hyphenated gas chromatography mass spectrometry (GC/MS technique. GC/MS analysis was carried out using Thermo Finnigan PolarisQ Ion Trap GC/MS MS system comprising of an AS2000 liquid autosampler. Interpretation on mass spectrum of GC/MS was done using the NIST/EPA/NIH Mass Spectral Database, with NIST MS search program v.2.0g. Chemometric profile of root extracts revealed the presence of 63 phyto-chemotypes, among them, 1-pentacosanol; stigmast-5-en-3-ol, (3β,24S; 1-teracosanol; 1-henteracontanol; 17-pentatriacontene; 13-tetradecen-1-ol acetate; methyl tri-butyl ammonium chloride; bis(2-ethylhexyl phthalate; 7,8-dimethylbenzocyclooctene; ethyl linoleate; 3-methoxy-5-methylphenol; hexadecanoic acid; camphor; 1,3-dimethoxybenzene; thujone; 1,3-benzenediol, 5-pentadecyl; benzenemethanol, 3-hydroxy, 5-methoxy; cholest-4-ene-3,6-dione; dodecanoic acid, 3-hydroxy; octadecane, 1-chloro; ethanone, 1-(4-hydroxyphenyl; α-tocopherol; ascaridole; campesterol; 1-dotriacontane; heptadecane, 9-hexyl were found to be present in major amount. Eventually, in the present study we have found phytosterols, terpenoids, fatty acids, fatty acid esters, alkyl halides, phenols, alcohols, ethers, alkanes, and alkenes as the major group of phyto-chemotypes in the different root extracts of R. imbricata. All these compounds identified by GC/MS analysis were further investigated for their biological activities and it was found that they possess a diverse range of positive pharmacological actions. In future, isolation of individual phyto-chemotypes and subjecting them to biological activity will definitely prove fruitful

  17. Thermodynamic-based retention time predictions of endogenous steroids in comprehensive two-dimensional gas chromatography.

    Science.gov (United States)

    Silva, Aline C A; Ebrahimi-Najafadabi, Heshmatollah; McGinitie, Teague M; Casilli, Alessandro; Pereira, Henrique M G; Aquino Neto, Francisco R; Harynuk, James J

    2015-05-01

    This work evaluates the application of a thermodynamic model to comprehensive two-dimensional gas chromatography (GC × GC) coupled with time-of-flight mass spectrometry for anabolic agent investigation. Doping control deals with hundreds of drugs that are prohibited in sports. Drug discovery in biological matrices is a challenging task that requires powerful tools when one is faced with the rapidly changing designer drug landscape. In this work, a thermodynamic model developed for the prediction of both primary and secondary retention times in GC × GC has been applied to trimethylsilylated hydroxyl (O-TMS)- and methoxime-trimethylsilylated carbonyl (MO-TMS)-derivatized endogenous steroids. This model was previously demonstrated on a pneumatically modulated GC × GC system, and is applied for the first time to a thermally modulated GC × GC system. Preliminary one-dimensional experiments allowed the calculation of thermodynamic parameters (ΔH, ΔS, and ΔC p ) which were successfully applied for the prediction of the analytes' interactions with the stationary phases of both the first-dimension column and the second-dimension column. The model was able to predict both first-dimension and second-dimension retention times with high accuracy compared with the GC × GC experimental measurements. Maximum differences of -8.22 s in the first dimension and 0.4 s in the second dimension were encountered for the O-TMS derivatives of 11β-hydroxyandrosterone and 11-ketoetiocholanolone, respectively. For the MO-TMS derivatives, the largest discrepancies were from testosterone (9.65 ) for the first-dimension retention times and 11-keto-etiocholanolone (0.4 s) for the second-dimension retention times.

  18. Triple sorbent thermal desorption/gas chromatography/mass spectrometry determination of vapor phase organic contaminants

    International Nuclear Information System (INIS)

    A thermal desorption/ps chromatography/mass spectrometry (TD/GC/MS) has been evaluated for the determination of volatile organic compounds (VOCS) in vapor phase samples using Carbosieve S-III/Carbotrap/Carotrap C triple sorbent traps (TST) similar to those available from a commercial source. The analysis was carried out with a Hewlett-Packard 5985A or 5995 GC/MS system with a modified injector to adapt an inhouse manufactured short-path desorber for transferring desorbate directly onto a cryofocusing loop for subsequent GC/MS analysis. Vapor phase standards generated from twenty six compounds were used for method validation, including alkanes, alkyl alcohols, alkyl ketones, and alkyl nitrites, a group of representative compounds that have previously been identified in a target airborne matrix. The method was validated based on the satisfactory results in terms of reproducibility, recovery rate, stability, and linearity. A relative, standard deviation of 0.55 to 24.3 % was obtained for the entire TD process (generation of gas phase standards, spiking the standards on and desorbing from TST) over a concentration range of 20 to 500 ng/trap. Linear correlation coefficients for the calibration curves as determined ranged from 0.81 to 0.99 and limits of detection ranged from 3 to 76 ng. For a majority of standards, recoveries of greater than 90% were observed. For three selected standards spiked on TSTS, minimal loss (10 to 22%) was observed after storing the spiked in, a 4 degree C refrigerator for 29 days. The only chromatographable artifact observed was a 5% conversion of isopropanol to acetone. The validated method been successfully applied, to the determination of VOCs collected from various emission sources in a diversified concentration range

  19. Analysis of the fatty acid composition of taraxicuum officinale flowers oil by gas chromatography mass spectrometer

    International Nuclear Information System (INIS)

    Taraxicum officinale, is a highly valuable medicinal plant. The roots is an important herbal drug, having long been used on the continent as a remedy for liver complaints. Keeping in view the importance and wide applications in the pharmaceutical industries, the present study was therefore aimed to analyze the chemical constituents of the flowers of T. officinale. The T. officinale flowers oil constituents of methyl ester derivatives of fatty acids were analyzed applying gas chromatography coupled to mass spectrometer. The results obtained showed the presence of both containing the saturated as well as unsaturated fatty acids in T. officinale flower oils. A total of 19 different components were identified and quantified. The concentration level of Methyl ester of Lenolenic acid was found very effective in concentration 3.33%, among the identified analytes of interest. In addition, the level of other chemical constituents of methyl ester of palmitic acid 3.11%, myristic acid 1.87, linolenic acids 1.67%, stearic acid 0.97 were found. The concentration level of the rest of identified fatty acids analytes were below 1%. Thus the results obtained from the current initiative is very promising due to the presence of high percentage of valuable analytes concentrations recorded in the fatty acid of T. officinale flower oil. Thus due to the presence of highly important analytes which have increased their importance for consumption in the pharmaceuticals as well as its applications in the new formulations for different skin, cosmetics and health purposes and for use by local practioners. The study will also provide a scientific database line. (author)

  20. Serum metabolic profiling of human gastric cancer based on gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Research on molecular mechanisms of carcinogenesis plays an important role in diagnosing and treating gastric cancer. Metabolic profiling may offer the opportunity to understand the molecular mechanism of carcinogenesis and help to non-invasively identify the potential biomarkers for the early diagnosis of human gastric cancer. The aims of this study were to explore the underlying metabolic mechanisms of gastric cancer and to identify biomarkers associated with morbidity. Gas chromatography/mass spectrometry (GC/MS) was used to analyze the serum metabolites of 30 Chinese gastric cancer patients and 30 healthy controls. Diagnostic models for gastric cancer were constructed using orthogonal partial least squares discriminant analysis (OPLS-DA). Acquired metabolomic data were analyzed by the nonparametric Wilcoxon test to find serum metabolic biomarkers for gastric cancer. The OPLS-DA model showed adequate discrimination between cancer and non-cancer cohorts while the model failed to discriminate different pathological stages (I-IV) of gastric cancer patients. A total of 44 endogenous metabolites such as amino acids, organic acids, carbohydrates, fatty acids, and steroids were detected, of which 18 differential metabolites were identified with significant differences. A total of 13 variables were obtained for their greatest contribution in the discriminating OPLS-DA model [variable importance in the projection (VIP) value >1.0], among which 11 metabolites were identified using both VIP values (VIP >1) and the Wilcoxon test. These metabolites potentially revealed perturbations of glycolysis and of amino acid, fatty acid, cholesterol, and nucleotide metabolism of gastric cancer patients. These results suggest that gastric cancer serum metabolic profiling has great potential in detecting this disease and helping to understand its metabolic mechanisms

  1. Characterization of Arsenic Biotransformation Products from an Open Anaerobic Degradation of Fucus distichus by Hydride Generation Gas Chromatography Atomic Absorption Spectrometry and High Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectrometry

    OpenAIRE

    Abiodun A. Ojo; Onasanya, Amos

    2013-01-01

    This work reports on the isolation and determination of biotransformation products obtained from the organoarsenic compounds that are present in Fucus distichus when it was subjected to an open anaerobic decomposition by using the Hydride Generation Gas Chromatography Atomic Absorption Spectrometry (HG-GC-AAS) and High Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectrometry (HPLC-ICP-MS). The seaweed and filtrate residues obtained from the open anaerobic degradation pro...

  2. An Ultra-Trace Analysis Technique for SF6 Using Gas Chromatography with Negative Ion Chemical Ionization Mass Spectrometry.

    Science.gov (United States)

    Jong, Edmund C; Macek, Paul V; Perera, Inoka E; Luxbacher, Kray D; McNair, Harold M

    2015-07-01

    Sulfur hexafluoride (SF6) is widely used as a tracer gas because of its detectability at low concentrations. This attribute of SF6 allows the quantification of both small-scale flows, such as leakage, and large-scale flows, such as atmospheric currents. SF6's high detection sensitivity also facilitates greater usage efficiency and lower operating cost for tracer deployments by reducing quantity requirements. The detectability of SF6 is produced by its high molecular electronegativity. This property provides a high potential for negative ion formation through electron capture thus naturally translating to selective detection using negative ion chemical ionization mass spectrometry (NCI-MS). This paper investigates the potential of using gas chromatography (GC) with NCI-MS for the detection of SF6. The experimental parameters for an ultra-trace SF6 detection method utilizing minimal customizations of the analytical instrument are detailed. A method for the detection of parts per trillion (ppt) level concentrations of SF6 for the purpose of underground ventilation tracer gas analysis was successfully developed in this study. The method utilized a Shimadzu gas chromatography with negative ion chemical ionization mass spectrometry system equipped with an Agilent J&W HP-porous layer open tubular column coated with an alumina oxide (Al2O3) S column. The method detection limit (MDL) analysis as defined by the Environmental Protection Agency of the tracer data showed the method MDL to be 5.2 ppt. PMID:25452581

  3. Determination of trace anions in liquefied petroleum gas using liquid absorption and electrokinetic migration for enrichment followed by ion chromatography.

    Science.gov (United States)

    Li, Meilan; Yang, Jianmin; Li, Hai-Fang; Lin, Jin-Ming

    2012-06-01

    A simple sample enrichment technique, electrokinetic migration enrichment in single phase using a designed device, coupled with ion chromatography is presented for the determination of four anions (H(2)PO(4)(-), Cl(-), NO(3)(-), and SO(4)(2-)) in liquefied petroleum gas by liquid adsorption. The electrokinetic migration enrichment is based on the phenomenon of ion electrokinetic migration to the opposite electrode. When the anions migrated to the anode in a smaller volume chamber under the electric field, the concentration was realized. The main parameters affecting enrichment efficiency of applied voltage and enrichment time were investigated. The ion chromatography condition for anions separation was also studied. Under the optimal electrokinetic migration enrichment and ion chromatography conditions, the four anions were detected simultaneously with good linear relationship (r(2) = 0.9908-0.9968) and high precisions (less than 5% of the relative standard deviations of peak areas). The limits of detection of anions (S/N of 3) were in the range of 8-600 μg L(-1). The enrichment factors of the four anions ranged from 3.1 to 5.8. The established method was successfully applied to the analysis of the trace anions in liquefied petroleum gas by liquid adsorption with satisfactory results. The advantages of this method are simple operation and low cost.

  4. Quantitative analysis of arbutin and hydroquinone in strawberry tree (Arbutus unedo L., Ericaceae) leaves by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Jurica, Karlo; Karačonji, Irena Brčić; Šegan, Sandra; Opsenica, Dušanka Milojković; Kremer, Dario

    2015-09-01

    The phenolic glycoside arbutin and its metabolite with uroantiseptic activity hydroquinone occur naturally in the leaves of various medicinal plants and spices. In this study, an extraction procedure coupled with gas chromatography-mass spectrometry (GC-MS) was developed to determine arbutin and hydroquinone content in strawberry tree (Arbutus unedo L., Ericaceae) leaves. The method showed good linearity (R2>0.9987) in the tested concentration range (0.5-200 μg mL(-1)), as well as good precision (RSDarbutin and hydroquinone, respectively). The results obtained by the validated GC-MS method corresponded well to those obtained by high performance liquid chromatography (HPLC) method. The proposed method was then applied for determining arbutin and hydroquinone content in methanolic leaf extracts. The amount of arbutin in the leaves collected on the island of Koločep (6.82 mg g(-1) dry weight) was found to be higher (tpaired=43.57, tc=2.92) in comparison to the amount of arbutin in the leaves collected on the island of Mali Lošinj (2.75 mg g(-1) dry weight). Hydroquinone was not detected in any of the samples. The analytical features of the proposed GC-MS method demonstrated that arbutin and hydroquinone could be determined alternatively by gas chromatography. Due to its wide concentration range, the method could also be suitable for arbutin and hydroquinone analysis in leaves of other plant families (Rosaceae, Lamiaceae, etc.). PMID:26444340

  5. Gas and liquid chromatography with inductively coupled plasma mass spectrometry detection for environmental speciation analysis — advances and limitations

    Science.gov (United States)

    Szpunar, Joanna; McSheehy, Shona; Połeć, Kasia; Vacchina, Véronique; Mounicou, Sandra; Rodriguez, Isaac; Łobiński, Ryszard

    2000-07-01

    Recent advances in the coupling of gas chromatography (GC) and high performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP MS) and their role in trace element speciation analysis of environmental materials are presented. The discussion is illustrated with three research examples concerning the following topics: (i) development and coupling of multicapillary microcolumn GC with ICP MS for speciation of organotin in sediment and biological tissue samples; (ii) speciation of arsenic in marine algae by size-exclusion-anion-exchange HPLC-ICP MS; and (iii) speciation of cadmium in plant cell cultures by size-exclusion HPLC-ICP MS. Particular attention is paid to the problem of signal identification in ICP MS chromatograms; the potential of electrospray MS/MS for this purpose is highlighted.

  6. Simultaneous determination of zearalenone and its derivatives in edible vegetable oil by gel permeation chromatography and gas chromatography-triple quadrupole mass spectrometry.

    Science.gov (United States)

    Qian, Mingrong; Zhang, Hu; Wu, Liqin; Jin, Nuo; Wang, Jianmei; Jiang, Kezhi

    2015-01-01

    A sensitive gas chromatographic-triple quadrupole mass spectrometric (GC-QqQ MS) analytical method, for the determination of zearalenone and its five derivatives in edible vegetable oil, was developed. After the vegetable oil samples were prepared using gel permeation chromatography, the eluent was collected, evaporated and dried with nitrogen gas. The residue was silylated with N,O-bis-trimethylsilyltrifluoroacetamide, containing 1% trimethylchlorosilane. GC-QqQ MS was performed in the reaction-monitoring mode to confirm and quantify mycotoxins in vegetable oil. The limits of quantitation were 0.03-0.2 μg kg(-1) for the six mycotoxins. The average recoveries, measured at 2, 20 and 200 μg kg(-1), were in the range 80.3-96.5%. Zearalenone was detected in the range 5.2-184.6 μg kg(-1) in nine maize oils and at 40.7 μg kg(-1) in a rapeseed oil from the local market.

  7. Supercritical fluid extraction and gas chromatography or electroanalysis of metal chelates from different sample matrices

    Science.gov (United States)

    Arancibia; Segura; Leiva; Contreras; Valderrama

    2000-01-01

    The supercritical fluid extraction of Pb(DDC)2 and MoO2(acac)2 complexes is performed. The previously formed complexes are used in order to simplify the extraction process. In the extraction cell, 9.0 mg of Pb(DDC)2 or 30.0 mg of MoO2(acac)2 is added. With these two complexes, a study of static and dynamic extraction as a function of pressure (1000-2500 psi), temperature (40-160 degrees C), and presence of modifier (methanol) is performed. Under the best conditions, 5.6 mg of Pb(DDC)2 (2.3 mg of Pb2+) is recovered. The parameters are 2500 psi of pressure, 160 degrees C of temperature, 0.5 mL methanol (placed in a 10-mL extraction cell), 60.0 min of static extraction, and 2.0 min of dynamic extraction. It is necessary to add 3.0 mL of methanol to enhance efficiency on the MoO2(acac)2 complex recovery. Quantitative extractions of MoO2(acac)2 (9.0 mg of MoVI) are obtained when the experiments are carried out under 1000-2500 psi of pressure, 140 degrees C, and times no longer than 10.0 min. Then, the study is carried out forming the in situ complexes. For this purpose, metallic ion and ligand are added. Under these conditions, the Pb2+ recovery decreases from 2.3 to 1.9 mg, and the MoVI recovery decreases from 9.0 to 1.0 mg. When 1.9 mg of Pb2+ and 1.0 mg of MoVI or less is placed in the extraction cell, the recoveries are always 100%. The Pb2+ extracts are directly accomplished using gas chromatography-flame ionization detection (GC-FID), and the MoVI extracts are analyzed using GC-FID and catalytic adsorption voltammetry. The quantitation of pure extracts is carried out by constructing calibration curves with complex solutions and sample solutions using the standard addition method. This method is applied by determination of Pb2+ in sodium alginate extracted from algae and blood, urine, and human milk from patients with diagnosed plumbunemy. MoVI is determined in irrigation water and pasture of animal intake.

  8. Separation performance of guanidinium-based ionic liquids as stationary phases for gas chromatography.

    Science.gov (United States)

    Qiao, Lizhen; Lu, Kai; Qi, Meiling; Fu, Ruonong

    2013-02-01

    Room temperature ionic liquids (RTILs) as stationary phases for gas chromatography (GC) have made great achievements in both research and applications over the last decades. Until now, all of the RTIL stationary phases reported have involved imidazolium, ammonium, pyrrolidinium, and phosphonium-based RTILs, and however, no publications are available using guanidinium-based ionic liquids (GBILs) as GC stationary phases except two preliminary reports from our group. In the present work, three hexaalkyl GBILs stationary phases, namely N, N,N',N'-tetramethyl-N″, N″-dioctylguanidinum hexafluophosphate (DOTMG-PF(6)), N,N,N',N'-tetramethyl-N″, N″-dioctylguanidinium bis (trifluoromethylsulfonyl) imide (DOTMG-NTf(2)), and N,N,N',N'-tetraoctyl-N″, N″-dimethylguanidinium bis (trifluoromethylsulfonyl) imide (TODMG-NTf(2)), were synthesized and used as stationary phases for GC separation after they were statically coated onto the inner walls of fused-silica capillary columns. The evaluation of DOTMG-PF(6) and TODMG-NTf(2) as GC stationary phases is reported here for the first time, whereas additional results on the DOTMG-NTf(2) stationary phase are added here on the basis of our previous report. In this work, McReynolds constants and Abraham solvation system constants are used to evaluate the average polarity and the solvation properties of the GBILs stationary phases for GC separation, respectively. The results show that the GBILs stationary phases exhibit medium polarity with an average polarity of 293-390, and that the major molecular interactions of the GBILs with analytes are dipole/polarizable interactions, H-bond basicity and dispersion forces, etc. After this, the separation performance and thermal stability of the GBILs stationary phases were evaluated, showing that these stationary phases achieve excellent separation for analytes of great variety covering hydrocarbons, alcohols, esters, aldehydes, ketones, amines, amides and aromatics, and exhibit

  9. Analysis of neonicotinoids by gas chromatography coupled to nuclide {sup 63}Ni - Electron Capture Detector - GC/ECD

    Energy Technology Data Exchange (ETDEWEB)

    Amaral, Priscila O.; Leao, Claudio; Redigolo, Marcelo M.; Crepaldi, Caike; Bustillos, Oscar V., E-mail: priscilaoamaral@gmail.com, E-mail: claudio.leao@usp.br, E-mail: marceloredigolo@gmail.com, E-mail: caike1995@gmail.com, E-mail: ovega@ipen.bremails [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Recently, several reports have been published discussing reduction in bee population which polymerizes cultures around the world this phenomenon is known as Colony Collapse Disorder (CCD). The phenomenon describes the lack of worker honeybees in the colony despite having pups and food. The causes of this problem are unknown but there are studies that claim that reduction of population of bees is linked to poisoning through insecticides specifically neonicotinoids. Among this type of pesticide are imidacloprid (C{sub 9}H{sub 10}ClN{sub 5}O{sub 2}), clothianidin (C{sub 6}H{sub 8}ClN{sub 5}O{sub 2}S) and thiamethoxam (C{sub 8}H{sub 10}ClN{sub 5}O{sub 3}S). This paper presents the analysis of neonicotinoids - clothianidin, imidacloprid and thiamethoxam - by the technique of gas chromatography coupled to nuclide {sup 63}Ni electron capture detector (GC/ECD). The electron capture detector (ECD) is a gas chromatography detector that has been used for the detection of organic halogens, nitriles, nitrates and organometallic compounds. The ECD detector ionizes the analytes by the beta particles from the nuclide sources {sup 63}Ni within carrier gas N{sub 2}. The electrons produced in this process are collected and create a current that are amplified and generates a chromatographic peak. Methodology and details of the analysis are present in this work. (author)

  10. Rapid Separation of Elemental Species by Fast Multicapillary Gas Chromatography with Multichannel Optical Spectrometry Detection following Headspace Solid Phase Microextraction

    Directory of Open Access Journals (Sweden)

    Jacek Giersz

    2015-05-01

    Full Text Available A method for conducting fast and efficient gas chromatography based on short multicapillaries in straight alignment combined with atomic emission detection was developed for field analysis. The strategy enables for speciation analysis of organometallic compounds. The analytes are simultaneously ethylated and preconcentrated on a solid phase microextraction (SPME fiber placed in the headspace over the sample for 25 min. The ethylated species are then completely separated and selectively quantified within 25 s under isothermal conditions. A new miniaturized speciation analyzer has been constructed and evaluated. The system consists of a GC injection port and a lab-made miniaturized GC unit directly coupled with miniaturized plasma excitation source. The emitted light is transferred via optical fiber and registered with a miniaturized charged coupled device (CCD based spectrometer. Working parameters for multicapillary column gas chromatography with atomic emission detector, including carrier gas flow rate, desorption temperature, and GC column temperature, were optimized to achieve good separation of analytes. Basic investigations of the fundamental properties of 5 cm-long multicapillary column, to evaluate its potential and limitations as a rapid separation unit, are presented. The adaptation of the technique for use with a SPME system and with a multichannel element-selective plasma-emission detector is highlighted.

  11. Thin Layer Chromatography-Bioautography and Gas Chromatography-Mass Spectrometry of Antimicrobial Leaf Extracts from Philippine Piper betle L. against Multidrug-Resistant Bacteria

    Science.gov (United States)

    Valle, Demetrio L.; Puzon, Juliana Janet M.; Cabrera, Esperanza C.

    2016-01-01

    This study isolated and identified the antimicrobial compounds of Philippine Piper betle L. leaf ethanol extracts by thin layer chromatography- (TLC-) bioautography and gas chromatography-mass spectrometry (GC-MS). Initially, TLC separation of the leaf ethanol extracts provided a maximum of eight compounds with Rf values of 0.92, 0.86, 0.76, 0.53, 0.40, 0.25, 0.13, and 0.013, best visualized when inspected under UV 366 nm. Agar-overlay bioautography of the isolated compounds demonstrated two spots with Rf values of 0.86 and 0.13 showing inhibitory activities against two Gram-positive multidrug-resistant (MDR) bacteria, namely, methicillin-resistant Staphylococcus aureus and vancomycin-resistant Enterococcus. The compound with an Rf value of 0.86 also possessed inhibitory activity against Gram-negative MDR bacteria, namely, carbapenem-resistant Enterobacteriaceae-Klebsiella pneumoniae and metallo-β-lactamase-producing Acinetobacter baumannii. GC-MS was performed to identify the semivolatile and volatile compounds present in the leaf ethanol extracts. Six compounds were identified, four of which are new compounds that have not been mentioned in the medical literature. The chemical compounds isolated include ethyl diazoacetate, tris(trifluoromethyl)phosphine, heptafluorobutyrate, 3-fluoro-2-propynenitrite, 4-(2-propenyl)phenol, and eugenol. The results of this study could lead to the development of novel therapeutic agents capable of dealing with specific diseases that either have weakened reaction or are currently not responsive to existing drugs. PMID:27478476

  12. Determination of anabolic esters in oily formulations and plasma in husbandry using high-performance liquid chromatography and gas chromatography-mass selective detection.

    Science.gov (United States)

    Hooijerink, D; Schilt, R; van Bennekom, E; Brouwer, B

    1994-12-01

    Two different analytical methods are described for the analysis of anabolic steroid esters in oily formulations for veterinary use and animal plasma samples, respectively. For the determination of anabolic steroid esters in oily formulations (at mg kg-1 levels) a reversed-phase high-performance liquid chromatographic method with gradient elution is described. Gradient elution is performed owing to the relatively large variations in polarity of the investigated anabolic steroid esters. For the analysis of anabolic steroid esters in plasma (at ng ml-1 levels) two different strategies are applied. After solid-phase extraction, the plasma samples are introduced into the high-performance liquid chromatography (HPLC) system where the obtained fractions are then analysed by using gas chromatography-mass selective detection (GC-MSD). An alternative method is direct analysis of plasma samples after solid-phase extraction by using GC-MSD without any further clean-up procedure. Prior to GC-MSD the samples are derivatized to corresponding trifluoroacyl (TFA) derivatives. The calibration graph for HPLC is rectilinear over the range 25-150 ng ml-1 plasma and the analytical recoveries for medroxyprogesterone acetate (MPA) and testosterone propionate (TP) are more than 95%. The detection limits for both analytes in GC-MS are 2.5 ng ml-1 plasma for MPA and 0.5 ng ml-1 plasma for TP with an acceptable signal-to-noise ratio (calculated for the derivatized relative molecular mass). In the analysis of plasma obtained from animal experiments concentrations of 6.5 ng ml-1 are found for MPA by using GC-MSD and 5.0 ng ml-1 are found for nortestosterone laurate (NL) by using HPLC. PMID:7879863

  13. Determination of crude oil fractions with the use of simulated distillation by gas chromatography as an alternative method

    International Nuclear Information System (INIS)

    In the oil industry it is very important to know the composition of the crude oil fractions, since it varies depending on their origin. It is feasible and profitable their industrial separation by distillation in fractions of different boiling points intervals for dissimilar applications, but before carrying out the industrial process it is necessary to determine in the laboratory the composition of each fraction for the adaptation of this purpose. Usually this is implemented by distillation at atmospheric and reduced pressures of the oil samples, although this determination could be made by simulated distillation using gas chromatography. A method of gas chromatography simulated distillation was established in order to its future application in Cuban refinery laboratories. It was performed using capillary gas chromatography with flame ionization detector. The test method consisted on a modification of the standard ASTM D5307-07 which establishes the use of packed columns, which were substituted by capillary columns. The samples were analyzed using a mixture of n-paraffins as internal standard (n-hexadecane, n-heptadecane, n-octadecane and n-nonadecane.). The tests of column resolution, determinations of the response factors and retention times repeatability were carried out. The statistical analysis shows good results in the repeatability and reproducibility tests. The composition of the different fractions of a number of samples of oil was obtained and they were compared with the results obtained by the classical method of True Boiling Points ASTM D 2892-05, being similar in both methods. It can be concluded that this method is possible to implant

  14. Comprehensive two-dimensional gas chromatography with a multi-capillary second dimension: A new column-set format for simultaneous optimum linear velocity operation

    NARCIS (Netherlands)

    D. Peroni; A.A.S. Sampat; W. van Egmond; S. de Koning; J. Cochran; R. Lautamo; H.-G. Janssen

    2013-01-01

    Comprehensive two-dimensional gas chromatography (GC x GC) suffers from the impossibility to operate both dimensions at their optimum carrier gas velocity at the same time due to the different inner diameters of the columns typically employed. The use of multiple parallel capillary columns in the se

  15. Research on the Interaction of Hydrogen-Bond Acidic Polymer Sensitive Sensor Materials with Chemical Warfare Agents Simulants by Inverse Gas Chromatography

    Directory of Open Access Journals (Sweden)

    Liu Yang

    2015-06-01

    Full Text Available Hydrogen-bond acidic polymers are important high affinity materials sensitive to organophosphates in the chemical warfare agent sensor detection process. Interactions between the sensor sensitive materials and chemical warfare agent simulants were studied by inverse gas chromatography. Hydrogen bonded acidic polymers, i.e., BSP3, were prepared for micro-packed columns to examine the interaction. DMMP (a nerve gas simulant and 2-CEES (a blister agent simulant were used as probes. Chemical and physical parameters such as heats of absorption and Henry constants of the polymers to DMMP and 2-CEES were determined by inverse gas chromatography. Details concerning absorption performance are also discussed in this paper.

  16. Applications of the gas chromatography in the nuclear science and technology; Aplicaciones de la cromatografia de gases a la ciencia y tecnologia nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Gasco Sanchez, L.

    1972-07-01

    This paper is a review on the applications of the gas chromatography in the nuclear science and technology published up to December 1971. Its contents has been classified under the following heads; I) Radiogaschromatography, II) Isotope separation, III) Preparation of labelled molecules, IV) Nuclear fuel cycle, V) Nuclear reactor technology, VI) Irradiation chemistry, VIl) Separation of me tal compounds in gas phase, VIII) Applications of the gas chromatography carried out at the Junta de Energia Nuclear, Spain. Arapter VIII only includes the investigations carried out from January 1969 to December 1971. Previous investigations in this field has been published elsewhere. (Author)

  17. Determination of alkyllead salts in water and whole eggs by capillary column gas chromatography with electron capture detection

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, D.S.; Marshall, W.D.

    1983-11-01

    Alkyllead salts (R/sub 3/Pb/sup +/ and R/sub 2/Pb/sup 2 +/, R = Methyl or Ethyl) are recovered from water or whole eggs by complexometric extraction with dithizone. The dithizonates are phenylated and speciated by capillary column gas chromatography with electron capture detection. The method is sensitive to low parts per billion levels of lead salts in 2.5 g egg homogenate. At these levels methyllead salts (but not ethyllead salts) interact strongly with the sample matrix. Treatment of the matrix with lipases and proteases releases them. 4 figures, 3 tables.

  18. Revolving fraction collector for preparative capillary gas chromatography in the 100-μg to 1-ng range.

    Science.gov (United States)

    Wassgren, A B; Bergström, G

    1984-11-01

    A gas chromatography fraction collector for use with capillary columns, consisting of an all-glass system with a revolving collector housing six capillary tubes, 100 × 1 mm (internal diameter), has been constructed and tested. The collector is cooled with solid CO2 and has a recovering efficiency of 50-75% in the 100-μg to 1-ng range for compounds of different polarities and volatilities, exemplified by mono- and sesquiter-penes and long-chain esters. The technique has been used for fractionating blends of semiochemicals prior to microchemical reactions, spectroscopic analyses, and behavioral experiments. PMID:24318389

  19. A simple and sensitive quantitation of N,N-dimethyltryptamine by gas chromatography with surface ionization detection.

    Science.gov (United States)

    Ishii, A; Seno, H; Suzuki, O; Hattori, H; Kumazawa, T

    1997-01-01

    A simple and sensitive method for determination of N,N-dimethyltryptamine (DMT) by gas chromatography (GC) with surface ionization detection (SID) is presented. Whole blood or urine, containing DMT and gramine (internal standard), was subjected to solid-phase extraction with a Sep-Pak C18 cartridge before analysis by GC-SID. The calibration curve was linear in the DMT range of 1.25-20 ng/mL blood or urine. The detection limit of DMT was about 0.5 ng/mL (10 pg on-column). The recovery of both DMT and gramine spiked in biological fluids was above 86%. PMID:9013290

  20. Detection of trace levels of triclopyr using capillary gas chromatography-electron-capture negative-ion chemical ionization mass spectrometry.

    Science.gov (United States)

    Begley, P; Foulger, B E

    1988-04-01

    Triclopyr, after esterification, is shown to be a suitable candidate for detection by gas chromatography-electron-capture negative-ion chemical ionization mass spectrometry forming a characteristic carboxylate anion which offers a high detection sensitivity. A detection limit of 70 fg reaching the ionizer is indicated. Low backgrounds and an absence of chemical interferences are shown for vegetation extracts, using a simple method of extraction and derivatisation. A similar behaviour is demonstrated for 2,4-D and 2,4,5-T. PMID:3379116

  1. [Autochthonous yeasts isolated in Tenerife wines and their influence on ethyl acetate and higher alcohol concentrations analyzed by gas chromatography].

    Science.gov (United States)

    Salvadores, M P; Díaz, M E; Cardell, E

    1993-12-01

    A taxonomic study of yeasts present on Tenerife wines, (Tacoronte-Acentejo Specific Denomination) has been carried out. Nine species of the genera: Saccharomyces, Torulaspora, Brettanomyces, Kluyveromyces, Debaryomyces, Saccharomycodes, Hansenula, Pichia and Candida have been isolated. Parallely we analysed volatile compounds of the wines such as ethyl acetate, methanol, isobutanol and amylic alcohols by gas chromatography. Appreciable quantities of ethyl acetate were detected due to the low fermentative power of species such as Candida glabrata and Debaryomyces hansenii. The greatest concentration of amylic alcohols were found in wines containing yeast with high alcohol producing power like Saccharomyces cerevisiae.

  2. Gas chromatography of alkylphosphonic and dialkyl phosphinic acids; Cromatografia en fase gaseosa de acidos alquifosfonicos y dialquilfosinicos

    Energy Technology Data Exchange (ETDEWEB)

    Gasco Sanchez, L.; Barrera Peniero, R.; Ramirez Caceres, A.; Marin Munoz, M.

    1978-07-01

    After carrying out an optimization study on the separation conditions for the TMSr- derivatives, of the hexyl-, cyclohexyl-, heptyl-, and octyl-phosphonic acids; dihexyl dicyclohexyl-, heptyl-, and octyl-phosphinic acids, and dioctyl phosphine oxide, their retention indices (I) at two temperatures and on the OV-1 and OV-17 stationary phase were determined. Correlations between I and molecular structure were established. Calibration factors of these compounds in the flame ionization detector were studied, and the results analyzed taking into account the variables affecting the quantitative results, These results were unbiased but they had a lower precision than that usually achievable in gas chromatography. (Author) 24 refs.

  3. Determination of Plasticizer in Food by Gas Chromatography and Gas Chromatography Mass Spectrometry%气相色谱及气相色谱-质谱法检测食品中增塑剂

    Institute of Scientific and Technical Information of China (English)

    张薇

    2016-01-01

    Plasticizer is a kind of polymer additives, in environmental estrogen, which belongs to the phthalic acid esters, in the middle of the industry, a very wide range of applications. Plasticizing agent is not used to the food, if eating human will to the reproductive system, endocrine system caused a lot of damage. Based on this, this article uses the test method, mainly takes the ortho benzene two formic acid ester compound as the example, has carried on the analysis to the use of gas chromatography and gas chromatography-mass spectrometry determination of the plasticizer in food.%增塑剂是一种高分子材料助剂,在环境雌激素中,属于酞酸酯类物质,在工业当中,有着十分广泛的应用。增塑剂不可应用于食品当中,如果人类误食,将会对生殖系统、内分泌系统造成很大的伤害。基于此,本文采用试验的方法,主要以邻苯二甲酸酯类化合物为例,对利用气相色谱及气相色谱-质谱法检测食品中的增塑剂进行了分析。

  4. Analysis of the chemical composition of the essential oils extracted from Lippia lacunosa Mart. and Schauer and Lippia rotundifolia Cham. (Verbenaceae) by gas chromatography and gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Leitao, Suzana G.; Barbosa, Ymira Galico [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Fac. de Farmacia; Oliveira, Danilo R. de; Leitao, Gilda G. [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Nucleo de Pesquisas de Produtos Naturais]. E-mail: sgleitao@pharma.ufrj.br; Suelsen, Valeria; Martino, Virginia [Universidad de Buenos Aires (Argentina). Facultad de Farmacia y Bioquimica; Bizzo, Humberto R.; Lopes, Daise [EMBRAPA Agroindustria de Alimentos, Rio de Janeiro, RJ (Brazil); Viccini, Lyderson F.; Salimena, Fatima R.G.; Peixoto, Paulo H.P. [Universidade Federal de Juiz de Fora (UFJF), Juiz de Fora, MG (Brazil). Inst. de Ciencias Biolgicas

    2008-07-01

    Lippia lacunosa and L. rotundifolia (Verbenaceae) are two Brazilian species of complex taxonomic delimitation. The composition of the essential oils from leaves and flowers of these plants was investigated by gas chromatography (GC) and gas chromatography coupled with mass spectrometry (GC-MS) analysis. The major components of the essential oils of flowers and leaves of L. lacunosa were: myrcene (14.7% and 11.9%), myrcenone (45.2% and 64.2%), Z-ocimenone (5.7% and 5.2%), and E-ocimenone (14.7% and 4.1%), respectively; whereas in L. rotundifolia (flowers and leaves) were ..-pinene (8.7% and 1.8%), myrcene (5.1% and 3.6%), limonene (26.0% and 7.9 %), cis-pinocamphone (4.5% and 3.1%) and myrtenal (22.3% and 16.7%), respectively. The essential oils from L. lacunosa exhibited a strong and pleasant mango aroma, which was related to the presence of myrcene and myrcenone. The marked differences in the chemical composition of their essential oils may represent a powerful tool for the botanical classification. (author)

  5. [Comparison of the performances of gas chromatography-quadrupole time of flight mass spectrometry and gas chromatography-tandem mass spectrometry in rapid screening and confirmation of 208 pesticide residues in fruits and vegetables].

    Science.gov (United States)

    Cao, Xinyue; Pang, Guofang; Jin, Linghe; Kang, Jian; Hu, Xueyan; Chang, Qiaoying; Wang, Minglin; Fan, Chunlin

    2015-04-01

    The performances of gas chromatography-tandem mass spectrometry (GC-MS/MS) and gas chromatography quadrupole time of flight mass spectrometry (GC-QTOF/MS) for the determination of 208 pesticide residues in fruit and vegetable samples, including apple, orange, tomato and cucumber, were compared comprehensively. Based on the differences of the two instruments, their respective characteristics and scopes of application in the detection of the pesticide residues were presented, which provided the reference for the analysis of pesticide residues. The performance parameters of the two instruments, such as overall recoveries, precisions, limits of detection, linear ranges, identification points and matrix effects, were evaluated according to a designed experiment. At three spiked levels (5.0, 10.0 and 20.0 µg/kg), the average recoveries for the majority of pesticides (93.0%) ranged from 70% to 120% in the four matrices with relative standard deviations below 20%. The limits of detection for most of the pesticides by GC-MS/MS and GC-Q-TOF/MS were less than 5.0 µg/kg. Compared with GC-QTOF/MS, GC-MS/MS showed relatively lower limits of detection and wider linear ranges, and its performance was more satisfactory in accurate quantitative analysis due to its superior sensitivity. On the other hand, GC-QTOF/MS provided accurate mass measurement, which was proved to be an efficient analytical tool on the rapid screening and confirmation of a large number of pesticides and non-target compounds.

  6. Analysis of the chemical composition of the essential oils extracted from Lippia lacunosa Mart. and Schauer and Lippia rotundifolia Cham. (Verbenaceae) by gas chromatography and gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Lippia lacunosa and L. rotundifolia (Verbenaceae) are two Brazilian species of complex taxonomic delimitation. The composition of the essential oils from leaves and flowers of these plants was investigated by gas chromatography (GC) and gas chromatography coupled with mass spectrometry (GC-MS) analysis. The major components of the essential oils of flowers and leaves of L. lacunosa were: myrcene (14.7% and 11.9%), myrcenone (45.2% and 64.2%), Z-ocimenone (5.7% and 5.2%), and E-ocimenone (14.7% and 4.1%), respectively; whereas in L. rotundifolia (flowers and leaves) were ..-pinene (8.7% and 1.8%), myrcene (5.1% and 3.6%), limonene (26.0% and 7.9 %), cis-pinocamphone (4.5% and 3.1%) and myrtenal (22.3% and 16.7%), respectively. The essential oils from L. lacunosa exhibited a strong and pleasant mango aroma, which was related to the presence of myrcene and myrcenone. The marked differences in the chemical composition of their essential oils may represent a powerful tool for the botanical classification. (author)

  7. Determination of Benzene, Toluene and Xylene (BTX Concentrations in Air Using HPLC Developed Method Compared to Gas Chromatography

    Directory of Open Access Journals (Sweden)

    Abdulrahman Bahrami

    2011-01-01

    Full Text Available A new method for analysis of benzene, toluene, and xylene (BTX using High Performance Liquid Chromatography-UV detection (HPLC-UV is described and compared to the gas chromatography (GC method. A charcoal adsorption tube connected to a small pump was used to obtain samples from an atmosphere chamber standard. Samples were extracted with methanol and analyzed by HPLC-UV. Chromatography was isocratic in a mobile phase consisting of water-methanol (30-70. The flow rate was set at 1 ml/min. The analyses were completely separated and were quantified using both methods. The results demonstrated no statistically significant differences between BTX concentrations between the two analytical methods with a correlation coefficient of 0.98-0.99. The GC method provided higher sensitivity than HPLC, but the HPLC determination of BTX were applicable to real samples because its sensivity was lower than the thershold limit recommended by the American Conference of Governmental Industrial Hygienist (ACGIH for an 8-hour workday.

  8. Analysis of four pentacyclic triterpenoid acids in several bioactive botanicals with gas and liquid chromatography and mass spectrometry detection.

    Science.gov (United States)

    Moldoveanu, Serban C; Scott, Wayne A

    2016-01-01

    Several pentacyclic triterpenoid acids including betulinic, oleanolic, and ursolic acids were reported to have health beneficial properties such as antiviral and anti-inflammatory properties, as well as the capability to inhibit "in vitro" the development of various cancer cell types. For this reason betulinic, oleanolic, and ursolic acids are used as neutraceuticals. For the analysis of the pentacyclic triterpenoid acids in complex plant materials, an improved scheme was developed, involving a qualitative screening using silylation and gas chromatography with mass spectrometry analysis, followed by quantitation using a novel liquid chromatography with tandem mass spectrometry procedure. The use of the two methods provides more reliable information regarding the plant materials with unknown composition. Besides betulinic, oleanolic, and ursolic acids that were analyzed, by this procedure a fourth pentacyclic triterpenoid acid was identified and quantitated that was not previously reported to be present in plants. This acid has been identified as 3β-3-hydroxy-lupa-18,20(29)-dien-28-oic acid. The newly identified acid has a structure as a derivative of lupane, although lupane with a double bond in the 18-position was not previously reported as present in plants. The new liquid chromatography with tandem mass spectrometry procedure developed for this study offers a very low limit of quantitation, excellent precision, and robustness. Rosemary was found to contain the largest levels of pentacyclic triterpenoid acids among all the analyzed botanicals. PMID:26549610

  9. A General Method for the Rapid Determination of Carbon-14- and Hydrogen-3-Labelled Substances by Gas Chromatography

    International Nuclear Information System (INIS)

    A method is described for the determination of 14C- and 3H- labelled substances by gas chromatography using different size flow counters. The method of cracking substances in a current of hydrogen gas is especially suitable for 3H-labelled compounds because it is free from the disadvantages encountered when the substances are first oxidized and the water formed subsequently converted. The general applicability of this method is shown for different classes of compounds. The analysis is independent of the chemical composition of the compound. By using a part oi the apparatus very rapid analyses of vaporizable 14C- and apparently all 3H-labelled substances can be made by direct injection into the reaction chamber. The apparatus can also be used for the oxidation procedure. (author)

  10. Tequila volatile characterization and ethyl ester determination by solid phase microextraction gas chromatography/mass spectrometry analysis.

    Science.gov (United States)

    Vallejo-Cordoba, Belinda; González-Córdova, Aarón Fernando; del Carmen Estrada-Montoya, María

    2004-09-01

    Solid phase microextraction (SPME) and gas chromatography were used for tequila volatile characterization and ethyl ester quantitation. Several factors determined the differences in tequila volatile profiles obtained by the SPME technique, namely, sampling mode, fiber coating, and fiber exposure time. Each of these factors determined the most suitable conditions for the analysis of volatile profiles in tequila. Volatile extraction consisted of placing 40 mL of tequila in a sealed vial kept at 40 degrees C. A poly(dimethylsiloxane) fiber was immersed in the liquid for 60 min and desorbed for 5 min into the gas chromatograph. The identified volatiles by mass spectrometry were mainly alcohols, esters, and ketones. The calibration curves for ethyl hexanoate, octanoate, and decanoate followed linear relationships with highly significant (p tequila samples. Quantitative differences in ethyl esters were found for the four most commonly known tequila types: silver, gold, aged, and extra-aged.

  11. Analysis of benzene, toluene, ethylbenzene and xylenes in soils by headspace and gas chromatography/flame ionization detector

    Directory of Open Access Journals (Sweden)

    Jurandir Pereira Pinto

    2006-02-01

    Full Text Available The constituents of gasoline: benzene, toluene, ethylbenzene and xylenes (BTEX are frequently found in soils due to leaks in fuel storage tanks and they present chronic toxicity. In this work it was developed and validated a methodology of BTEX analysis in soil by gas chromatography/ flame ionization detector and static headspace. The recovery of BTEX in soil samples was evaluated using soils with different textures (sandy and loamy. The analysis method showed good resolution, in a low time of analysis (less than 30 minutes. Limits of quantification of 0.05 mg Kg¯¹ soil for benzene, toluene, ethylbenzene and xylenes are below the guiding values that range from 0.15 to 95 mg Kg¯¹ soil, established to determine soil quality. It was verified that the methodology enables the use of this method for BTEX analysis of soil samples for passive environmental identification of gas stations.

  12. Hydrocarbon gases emitted from vehicles on the road. 1. A qualitative gas chromatography/mass spectrometry survey

    Energy Technology Data Exchange (ETDEWEB)

    Hampton, C.V.; Pierson, W.R.; Harvey, T.M.; Updegrove, W.S.; Marano, R.S.

    1982-05-01

    The gas-phase hydrocarbons greater than or equal to C/sub 5/ generated by motor vehicles in highway operation were surveyed in the Allegheny Mountain Tunnel of the Pennsylvania Turnpike in 1979. The samples were collected on Tenax GC polymer adsorbent and analyzed by glass-capillary gas chromatography/mass spectrometry. Approximately 400 vehicle-generated compounds were detected. Of these, over 300 were either completely or partially identified. In the various tunnel samples the same peaks are always present, with relative intensities varying according to the traffic composition. The compounds identified fall largely into homolgous series of normal and branched alkanes, alkenes, and various alkyl series based on cyclopentane, cyclohexane, benzene, styrene, indan, naphthalene, and decalin. Compounds not associated with homolgous series include indene, divinylbenzene, phenylacetylene, benzaldehyde, phenol, and a few halocarbons. Results from a preliminary experiment in 1977 at the Tuscarora Mountain Tunnell are also reported.

  13. Determination of synthetic phenolic antioxidants in edible oils using microvial insert large volume injection gas-chromatography.

    Science.gov (United States)

    Cacho, Juan Ignacio; Campillo, Natalia; Viñas, Pilar; Hernández-Córdoba, Manuel

    2016-06-01

    Three synthetic phenolic antioxidants, butylated hydroxyanisole (BHA), butylated hydroxytoluene (BHT) and tert-butyl hydroquinone (TBHQ), were determined in different edible vegetable oil samples. The analyses were carried out by gas chromatography-mass spectrometry (GC-MS) using microvial insert large volume injection (LVI). Several parameters affecting this sample introduction step, such as temperatures, times and gas flows, were optimised. Quantification was carried out by the matrix-matched calibration method using carvacrol as internal standard, providing quantification limits between 0.08 and 0.10 ng g(-1), depending on the compound. The three phenolic compounds were detected in several of the samples, BHT being the most frequently found. Recovery assays for oil samples spiked at two concentration levels, 2.5 and 10 ng g(-1), provided recoveries in the 86-115% range. PMID:26830586

  14. A micro gas chromatography with separation capability enhanced by polydimethylsiloxane stationary phase functionalized by carbon nanotubes and graphene.

    Science.gov (United States)

    Li, Yubo; Zhang, Runzhou; Wang, Tao; Wang, Youhao; Wang, Yonghuan; Li, Lingfeng; Zhao, Weijun; Wang, Xiaozhi; Luo, Jikui

    2016-07-01

    Polydimethylsiloxane (PDMS) stationary phases functionalized with multi-walled carbon nanotubes (MWCNTs) and graphene, respectively, for the columns in micro gas chromatography are presented in this paper. To exploit the merits of MWCNTs and graphene in terms of their high specific surface area, low surface energy and chemical inertness, experimental conditions for separation (heating rate and final temperature of temperature programming, flow rate of carrier gas and the volume of samples injection) are investigated, and separations of both polar and nonpolar compound mixtures under these conditions are performed. Compared with PDMS-only coated stationary phases, the functionalization of the phases with carbon nano-materials improves the performance of columns in separation, repeatability, stability and revolution significantly.

  15. Thermal desorption gas chromatography and positron annihilation spectroscopy, contribution to alpha decay studies in actinide-doped matrices

    Energy Technology Data Exchange (ETDEWEB)

    Roudil, D.; Jegou, C.; Vella, F.; Folch, B.; Broudic, V. [Commissariat a l' energie Atomique, Rhone Valley Research Center, 30200 Bagnols-sur-Ceze (France); Pik, R. [CNRS-CRPG, 54506 Vandoeuvre-les-Nancy (France); Barthe, M. F. [CNRS-CEMHTI, 45071 Orleans (France); Cuney, M. [Universite de Nancy, CNRS, CREGU, 54506 Vandoeuvre-les-Nancy (France); Pipon, Y. [IPNL CNRS, IN2P3 UMR 5822, 69622 Villeurbanne (France)

    2009-07-01

    A thermal desorption system coupled with a gas analyzer has been adapted and nuclearized to investigate He behavior in actinide-doped samples used to simulate alpha decay aging. This technique widely used in standard laboratories allows measurements of the helium balance and reduced diffusion coefficients, and a preliminary evaluation of helium locations (related to defects and thermal annealing). In our system implemented in a hot cell, small samples are annealed at up to 1100 C degrees in controlled atmosphere. They are inserted in a 10 to 20 cm{sup 3} vessel connected to a micro gas chromatography detector. Initial system calibration allowed concentration measurements within about 10%. Comparisons with the CNRS/CRPG rare gas analysis laboratory at Nancy (France) were applied on natural uranium oxides originating from Oklo (Gabon) and Mistamisk (Canada). The latest results obtained on Mistamisk samples are in good agreement, with a maximum relative deviation of 14%. The data were used to determine the activation energy of about 1 eV.at{sup -1}. On (U,Pu)O{sub 2} and PuO{sub 2} samples the experiments highlight the impact of defects (up to 100 dpa) on He mobility. The defect population must now be characterized to improve our knowledge of He/defect interactions and mechanisms. In addition and synergy to the macroscopic release measurements by gas chromatography, positron annihilation spectroscopy, an effective nondestructive technique for vacancy defect investigation, was also developed and nuclearized in our hot cell laboratory as part of a project supported by the NOMADE and MATINEX research groups. Specific protocols for doped sample analysis were also developed and validated with UO{sub 2} and (U,Pu)O{sub 2} samples. (authors)

  16. Fully automated determination of the sterol composition and total content in edible oils and fats by online liquid chromatography-gas chromatography-flame ionization detection.

    Science.gov (United States)

    Nestola, Marco; Schmidt, Torsten C

    2016-09-01

    Sterol analysis of edible oils and fats is important in authenticity control. The gas chromatographic determination of the sterol distribution and total content is described by ISO norm 12228. Extraction, purification, and detection of the sterols are time-consuming and error-prone. Collaborative trials prove this regularly. Purification by thin-layer chromatography (TLC) and robust GC determination of all mentioned sterols is not straightforward. Therefore, a fully automated LC-GC-FID method was developed to facilitate the determination of sterols. The only manual step left was to weigh the sample into an autosampler vial. Saponification and extraction were performed by an autosampler while purification, separation, and detection were accomplished by online coupled normal-phase LC-GC-FID. Interlacing of sample preparation and analysis allowed an average sample throughput of one sample per hour. The obtained quantitative results were fully comparable with the ISO method with one apparent exception. In the case of sunflower oils, an additional unknown sterol was detected generally missed by ISO 12228. The reason was found in the omission of sterol silylation before subjection to GC-FID. The derivatization reaction changed the retention time and hid this compound behind a major sterol. The compound could be identified as 14-methyl fecosterol. Its structure was elucidated by GC-MS and ensured by HPLC and GC retention times. Finally, validation of the designed method confirmed its suitability for routine environments. PMID:27522150

  17. Quantitative analysis of arbutin and hydroquinone in strawberry tree (Arbutus unedo L., Ericaceae) leaves by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Jurica, Karlo; Karačonji, Irena Brčić; Šegan, Sandra; Opsenica, Dušanka Milojković; Kremer, Dario

    2015-09-01

    The phenolic glycoside arbutin and its metabolite with uroantiseptic activity hydroquinone occur naturally in the leaves of various medicinal plants and spices. In this study, an extraction procedure coupled with gas chromatography-mass spectrometry (GC-MS) was developed to determine arbutin and hydroquinone content in strawberry tree (Arbutus unedo L., Ericaceae) leaves. The method showed good linearity (R2>0.9987) in the tested concentration range (0.5-200 μg mL(-1)), as well as good precision (RSD<5%), analytical recovery (96.2-98.0%), and sensitivity (limit of detection=0.009 and 0.004 μg mL(-1) for arbutin and hydroquinone, respectively). The results obtained by the validated GC-MS method corresponded well to those obtained by high performance liquid chromatography (HPLC) method. The proposed method was then applied for determining arbutin and hydroquinone content in methanolic leaf extracts. The amount of arbutin in the leaves collected on the island of Koločep (6.82 mg g(-1) dry weight) was found to be higher (tpaired=43.57, tc=2.92) in comparison to the amount of arbutin in the leaves collected on the island of Mali Lošinj (2.75 mg g(-1) dry weight). Hydroquinone was not detected in any of the samples. The analytical features of the proposed GC-MS method demonstrated that arbutin and hydroquinone could be determined alternatively by gas chromatography. Due to its wide concentration range, the method could also be suitable for arbutin and hydroquinone analysis in leaves of other plant families (Rosaceae, Lamiaceae, etc.).

  18. Gas chromatography: Possible application of advanced instrumentation developed for solar system exploration to space station cabin atmospheres

    Science.gov (United States)

    Carle, G. C.

    1985-01-01

    Gas chromatography (GC) technology was developed for flight experiments in solar system exploration. The GC is a powerful analytical technique with simple devices separating individual components from complex mixtures to make very sensitive quantitative and qualitative measurements. It monitors samples containing mixtures of fixed gases and volatile organic molecules. The GC was used on the Viking mission in support of life detection experiments and on the Pioneer Venus Large Probe to determine the composition of the venusian atmosphere. A flight GC is under development to study the progress and extent of STS astronaut denitrogenation prior to extravehicular activity. Advanced flight GC concepts and systems for future solar system exploration are also studied. Studies include miniature ionization detectors and associated control systems capable of detecting from ppb up to 100% concentration levels. Further miniaturization is investigated using photolithography and controlled chemical etching in silicon wafers. Novel concepts such as ion mobility drift spectroscopy and multiplex gas chromatography are also developed for future flight experiments. These powerful analytical concepts and associated hardware are ideal for the monitoring of cabin atmospheres containing potentially dangerous volatile compounds.

  19. Simultaneous Determination of Hexoestrol, Diethylstilbestrol, Estrone and 17-Beta-estradiol in Feed by Gas Chromatography-mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    Huo Feng; Li Ning; Lin Xiao-Li

    2016-01-01

    A method was developed for the simultaneous determination of four kinds of estrogens (hexoestrol, diethylstilbestrol, estrone, and 17-beta-estradiol) in feed by gas chromatography-mass spectrometry (GC-MS). After the sample was extracted by ethyl ether and cleaned-up on HLB phase extraction column, four kinds of estrogens were derived and quantified in gas chromatography-mass spectrometry. The results showed that the linear detectable ranged from 2.5 ng•mL-1 to 250 ng•mL-1 for hexoestrol and from 5 ng•mL-1 to 500 ng•mL-1 for three other estrogens with the correlation coefficients (R2) were no less than 0.990. The recoveries were in the range of 76.34%-96.33% and the relative standard deviation was no more than 22.7%. The limits of quantitation (LOQ) for all analytics were between 10 ug•kg-1 and 20 ug•kg-1. The method was accurate and sensitive and could meet the actual requirements for the analyses of feed samples.

  20. Determination of Trichlorfon Pesticide Residues in Milk via Gas Chromatography with μ-Electron Capture Detection and GC-MS.

    Science.gov (United States)

    Hem, Lina; Khay, Sathya; Choi, Jeong-Heui; Morgan, E D; Abd El-Aty, A M; Shim, Jae-Han

    2010-06-01

    The pesticide trichlorfon is readily degraded under experimental conditions to dichlorvos. A method has therefore been developed by which residues of trichlorfon in milk are determined as dichlorvos, using gas chromatography with μ-electron capture detection. The identification of dichlorvos was confirmed by mass spectrometry. Milk was extracted with acetonitrile followed by centrifugation, freezing lipid filtration, and partitioning into dichloromethane. The residue after partitioning of dichloromethane was dissolved in ethyl acetate for gas chromatography. Recovery concentration was determined at 0.5, 1.0, and 2.0 of times the maximum permitted residue limits (MRLs) for trichlorfon in milk. The average recoveries (n = 6) ranged from 92.4 to 103.6%. The repeatability of the measurements was expressed as relative standard deviations (RSDs) ranging from 3.6%, to 6.7%. Limit of detection (LOD) and limit of quantification (LOQ) were 3.7 and 11.1 μg/l, respectively. The accuracy and precision (expressed as RSD) were estimated at concentrations from 25 to 250 μg/l. The intra- and inter-day accuracy (n = 6) ranged from 89.2%to 91% and 91.3% to 96.3%, respectively. The intra- and inter-day precisions were lower than 8%. The developed method was applied to determine trichlorfon in real samples collected from the seven major cities in the Republic of Korea. No residual trichlorfon was detected in any samples. PMID:24278518

  1. Analysis of Essential Oil in Jerusalem Artichoke (Helianthus tuberosus L.) Leaves and Tubers by Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    Helmi, Zead; Al Azzam, Khaldun Mohammad; Tsymbalista, Yuliya; Ghazleh, Refat Abo; Shaibah, Hassan; Aboul-Enein, Hassan

    2014-01-01

    Purpose: To investigate, for the first time, the chemical composition of essential oil of the tubers and leaves of Jerusalem artichoke (Helianthus tuberosus L.), a species of sunflower native to eastern North America, growing in Ukraine. Methods: A hydrodistillation apparatus was used for the extraction of volatile components and then it was analysed by gas chromatography equipped with a split-splitless injector (split ratio, 1:50) and flame ionization detector (FID). The oil was analyzed under linear temperature programming applied at 4°C/min from 50°C - 340°C. Temperatures of the injector and FID detector were maintained at 280°C and 300°C, respectively. The chemical analysis of the oil was carried out using gas chromatography coupled to mass spectrometry (GC-MS), to determine the chemical composition of the volatile fraction. Results: The essential oils content ranged from 0.00019 to 0.03486 and 0.00011 to 0.00205 (g/100g), in leaves and tubers, respectively. The qualitative and quantitative analysis led to the identification of 17 components in both species samples. The major component found in leaves and tubers was (-)-β-bisabolene with 70.7% and 63.1%, respectively. Conclusion: Essential oil profile of Jerusalem artichoke species showed significant differences between leaves and tubers species. Additionally, the leaves of Jerusalem artichoke are a promising source of natural β-bisabolene. PMID:25671184

  2. Analysis of capsaicin and dihydrocapsaicin in peppers and pepper sauces by solid phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Peña-Alvarez, Araceli; Ramírez-Maya, Erika; Alvarado-Suárez, Luís Angel

    2009-04-01

    A simple method for the analysis of capsaicin and dihydrocapsaicin in peppers and pepper sauces by solid phase microextraction-gas chromatography-mass spectrometry has been developed. A novel device was designed for direct extraction solid phase microextraction in order to avoid damage to the fiber. The analysis was performed without derivatization for the gas chromatography-mass spectrometry analysis. Selection fiber, extraction temperature, extraction time and pH, were optimized. The method was linear in the range 0.109-1.323 microg/mL for capsaicin and 0.107-1.713 microg/mL for dihydrocapsaicin with correlation coefficient up to r=0.9970 for both capsaicinoids. The precision of the method was less than 10%. The method was applied to the analysis of 11 varieties of peppers and four pepper sauces. A broad range of capsaicin (55.0-25 459 microg/g) and dihydrocapsaicin (93-1 130 microg/g) was found in the pepper and pepper sauces samples (4.3-717.3 and 1.0-134.8 microg/g), respectively.

  3. Application of integrated comprehensive/multidimensional gas chromatography with mass spectrometry and olfactometry for aroma analysis in wine and coffee.

    Science.gov (United States)

    Chin, Sung-Tong; Eyres, Graham T; Marriott, Philip J

    2015-10-15

    Component coelution in chromatographic analysis complicates identification and attribution of individual odour-active volatile molecules in complex multi-component samples. An integrated system incorporating comprehensive two-dimensional gas chromatography (GC × GC) and multidimensional gas chromatography (MDGC), with flame ionisation, olfactometry and mass spectrometry detection was developed to circumvent data correlation across different systems. Identification of potent odorants in Shiraz wine and the headspace of ground coffee are demonstrated as selected applications. Multiple solid-phase microextraction (SPME) sampling with GC-O located odour-active regions; GC × GC established the complexity of odour-active regions; MDGC provided high-resolution separation for each region; simultaneous 'O' and MS detection completed the analysis for target resolved peaks. Seven odour regions in Shiraz were analysed with MDGC-O/MS detection, revealing 11 odour volatiles through matching of mass spectrometry and retention indices from both separating dimensions, including acetic acid; octen-3-ol; ethyl octanoate; methyl-2-oxo-nonanoate; butanoic acid, 2-methylbutanoic acid, and 3-methylbutanoic acid; 3-(methylthio)-1-propanol; hexanoic acid; β-damascenone; and ethyl-3-phenylpropanoate. A capsicum odour in ground coffee was identified as 2-methoxy-3-isobutylpyrazine with a 5-fold increase in S/N of the odorant when acquired using a 6-time cumulative SPME sampling approach.

  4. Using comprehensive two-dimensional gas chromatography to explore the geochemistry of the Santa Barbara oil seeps

    Energy Technology Data Exchange (ETDEWEB)

    Reddy, Christopher; Nelson, Robert

    2013-03-27

    The development of comprehensive two-dimensional gas chromatography (GC x GC) has expanded the analytical window for studying complex mixtures like oil. Compared to traditional gas chromatography, this technology separates and resolves at least an order of magnitude more compounds, has a much larger signal to noise ratio, and sorts compounds based on their chemical class; hence, providing highly refined inventories of petroleum hydrocarbons in geochemical samples that was previously unattainable. In addition to the increased resolution afforded by GC x GC, the resulting chromatograms have been used to estimate the liquid vapor pressures, aqueous solubilities, octanol-water partition coefficients, and vaporization enthalpies of petroleum hydrocarbons. With these relationships, powerful and incisive analyses of phase-transfer processes affecting petroleum hydrocarbon mixtures in the environment are available. For example, GC x GC retention data has been used to quantitatively deconvolve the effects of phase transfer processes such as water washing and evaporation. In short, the positive attributes of GC x GC-analysis have led to a methodology that has revolutionized the analysis of petroleum hydrocarbons. Overall, this research has opened numerous fields of study on the biogeochemical "genetics" (referred to as petroleomics) of petroleum samples in both subsurface and surface environments. Furthermore, these new findings have already been applied to the behavior of oil at other seeps as well, for petroleum exploration and oil spill studies.

  5. Characterization of phenol and alkyl phenols in organic matrixes with monoethylene glycol extraction and multidimensional gas chromatography/mass spectrometry.

    Science.gov (United States)

    Luong, J; Gras, R; Cortes, H J; Shellie, R A

    2013-07-01

    The use of monoethylene glycol as an extraction medium for removing phenol and alkyl phenols in organic matrixes such as hydrocarbons is introduced and combined with a practical analytical multidimensional gas chromatography approach. The analytical approach has been successfully developed for the characterization of phenol, cresols, xylenols, and alkyl phenols like 4-ethylphenol and 2,3,5-trimethylphenol. The technique employs a single-step extraction of the analytes with monoethylene glycol and sonication, followed by multidimensional gas chromatography with mass spectrometry in selected ion monitoring mode for the detection and quantitation. Extraction efficiency of phenol approached 100% while cresols, xylenols, and 4-ethylphenol were 97% or higher and 2,3,5-trimethylphenol was better than 91% under the analytical conditions used. With the technique described, a complete analysis can be conducted in less than 16 min. Reproducibility of area counts at two levels, namely, 5 ppm(w) and 50 ppm(w) over a period of 2 days were found to be less than 4% (n = 20). The analytes of interest was found to be linear over a range from 100 ppb(w) to 250 ppm(w) with correlation coefficient of at least 0.999 and detection limit of 50 ppb(w) . Spike recoveries from 500 ppb(w) to 250 ppm(w) for all analytes range from 96 to 102%.

  6. Novel molecularly-imprinted solid-phase microextraction fiber coupled with gas chromatography for analysis of furan.

    Science.gov (United States)

    Hashemi-Moghaddam, Hamid; Ahmadifard, Mojtaba

    2016-04-01

    This study combined a molecularly-imprinted polymer with headspace solid-phase microextraction (HS-SPME). Preparation of molecularly-imprinted polymer is not effective for volatile compounds. To overcome this limitation, pyrrole was chosen as a template for the preparation of the furan-imprinted polymer. The holes in the synthesized polymer were suitable for furan adsorption because the chemical structure of pyrrole is similar to that of furan. The extraction properties of the fiber to furan were examined using an HS-SPME device coupled with gas chromatography-flame ionization detection (GC-FID) and gas chromatography-mass spectrometry (GC-MS). The effects of the extraction parameters of exposure time, sampling temperature, and salt concentration on extraction efficiency were studied. Satisfactory reproducibility was obtained for extractions from spiked water samples at RSDdetection limit for furan was 0.042 ng ml(-1). The fabricated fiber was successfully applied for headspace extraction of furan from tap water and canned tuna as shown by GC-MS analysis. PMID:26838393

  7. Potential of monitoring isotopologues by quantitative gas chromatography with time-of-flight mass spectrometry for metabolomic assay.

    Science.gov (United States)

    Wang, Yi; Hu, Haiyan; Su, Yue; Zhang, Fang; Guo, Yinlong

    2016-03-01

    Because of the extreme complexity of metabolomic samples, the effectiveness of quantitative gas chromatography with time-of-flight mass spectrometry depends substantially on the expansion of the linear dynamic range. Facing the existence of numerous saturated detector signals, a data processing method based on monitoring isotopologues has been developed. The monoisotopic ion kept the high mass spectrometry sensitivity, and the less abundant isotopologue ions extended the linear dynamic range. This alternative method was proved to extend the linear dynamic range to five orders of magnitude successfully and overcome the quantitative problems induced by the ion detector saturation. Finally, to validate the applicability, the method was applied to a metabolomic assay of Alzheimer's disease. Comparing with the traditional monoisotopic method, the use of monitoring isotopologues helped us to discover an additional eight metabolites with significant difference and to conduct a more reliable principal component analysis as well. The results demonstrated that monitoring isotopologues in quantitative gas chromatography with time-of-flight mass spectrometry could improve the authenticity of metabolomic analysis. PMID:26763370

  8. Analysis of selective androgen receptor modulators by gas chromatography-microchip atmospheric pressure photoionization-mass spectrometry.

    Science.gov (United States)

    Luosujärvi, Laura; Haapala, Markus; Thevis, Mario; Saarela, Ville; Franssila, Sami; Ketola, Raimo A; Kostiainen, Risto; Kotiaho, Tapio

    2010-02-01

    A gas chromatography-microchip atmospheric pressure photoionization-mass spectrometric (GC-microAPPI-MS) method was developed and used for the analysis of three 2-quinolinone-derived selective androgen receptor modulators (SARMs). SARMs were analyzed from spiked urine samples, which were hydrolyzed and derivatized with N-methyl-N-(trimethylsilyl)trifluoroacetamide before analysis. Trimethylsilyl derivatives of SARMs formed both radical cations (M(+*)) and protonated molecules ([M + H](+)) in photoionization. Better signal-to-noise ratios (S/N) were obtained in MS/MS analysis using the M(+*) ions as precursor ions than using the [M + H](+) ions, and therefore the M(+*) ions were selected for the precursor ions in selected reaction monitoring (SRM) analysis. Limits of detection (LODs) with the method ranged from 0.01 to 1 ng/mL, which correspond to instrumental LODs of 0.2-20 pg. Limits of quantitation ranged from 0.03 to 3 ng/mL. The mass spectrometric response to the analytes was linear (R > or = 0.995) from the LOQ concentration level up to 100 ng/mL concentration, and intra-day repeatabilities were 5%-9%. In addition to the GC-microAPPI-MS study, the proof-of-principle of gas chromatography-microchip atmospheric pressure chemical ionization-Orbitrap MS (GC-microAPCI-Orbitrap MS) was demonstrated.

  9. Potential of needle trap microextraction-portable gas chromatography-mass spectrometry for measurement of atmospheric volatile compounds

    Science.gov (United States)

    Feijó Barreira, Luís Miguel; Xue, Yu; Duporté, Geoffroy; Parshintsev, Jevgeni; Hartonen, Kari; Jussila, Matti; Kulmala, Markku; Riekkola, Marja-Liisa

    2016-08-01

    Volatile organic compounds (VOCs) play a key role in atmospheric chemistry and physics. They participate in photochemical reactions in the atmosphere, which have direct implications on climate through, e.g. aerosol particle formation. Forests are important sources of VOCs, and the limited resources and infrastructures often found in many remote environments call for the development of portable devices. In this research, the potential of needle trap microextraction and portable gas chromatography-mass spectrometry for the study of VOCs at forest site was evaluated. Measurements were performed in summer and autumn 2014 at the Station for Measuring Ecosystem-Atmosphere Relations (SMEAR II) in Hyytiälä, Finland. During the first part of the campaign (summer) the applicability of the developed method was tested for the determination of monoterpenes, pinonaldehyde, aldehydes, amines and anthropogenic compounds. The temporal variation of aerosol precursors was determined, and evaluated against temperature and aerosol number concentration data. The most abundant monoterpenes, pinonaldehyde and aldehydes were successfully measured, their relative amounts being lower during days when particle number concentration was higher. Ethylbenzene, p- and m-xylene were also found when wind direction was from cities with substantial anthropogenic activity. An accumulation of VOCs in the snow cover was observed in the autumn campaign. Results demonstrated the successful applicability of needle trap microextraction and portable gas chromatography-mass spectrometry for the rapid in situ determination of organic gaseous compounds in the atmosphere.

  10. Analysis of tert-butyldimethylsilyl derivatives in heavy gas oil from Brazilian naphthenic acids by gas chromatography coupled to mass spectrometry with electron impact ionization.

    Science.gov (United States)

    Vaz de Campos, Maria Cecília; Oliveira, Eniz Conceição; Filho, Pedro José Sanches; Piatnicki, Clarisse Maria Sartori; Caramão, Elina Bastos

    2006-02-10

    Naphthenic acids, C(n)H(2n+Z)O(2), are a complex mixture of alkyl-substituted acyclic and cycle-aliphatic carboxylic acids. The content of naphthenic acids and their derivatives in crude oils is very small, which hinders their extraction from matrixes of wide and varied composition. In this work, liquid-liquid extraction, followed by solid phase extraction with an ion exchange resin (Amberlyst A-27) and ultrasound desorption were used to isolate the acid fraction from heavy gas oil of Marlim petroleum (Campos, Rio de Janeiro, Brazil). The analysis was accomplished through gas chromatography coupled to mass spectrometry with electron impact ionization, after derivatization with N-methyl-N-(tert-butyldimethylsilyl)trifluoracetamide (MTBDMSTFA). The results indicate the presence of carboxylic acids belonging to families of alicyclic and naphthenic compounds which contain up to four rings in the molecule. PMID:16439253

  11. Distillation simulée par chromatographie en phase gazeuse sur des coupes lourdes de pétrole Simulated Distillation of Heavy Oil Cuts by Gas Chromatography

    Directory of Open Access Journals (Sweden)

    Petroff N.

    2006-11-01

    Full Text Available Ce travail est le fruit d'une action concertée entre Institut Français du Pétrole (IFP, Compagnie Française de Raffinage (CFR et Société Nationale Elf Aquitaine (Production (SNEA (P au sein du GEC (Groupe d'Etudes Concertées sur l'analyse des fractions lourdes du pétrole. On décrit dans cette étude une méthode de chromatographie gazeuse permettant de caractériser par une courbe de distillation simulée, des coupes lourdes 370-535 °C, obtenues par distillation sous vide des résidus atmosphériques. Un mode opératoire détaillé est fourni, contenant des indications précises sur la préparation des colonnes, leur conditionnement, leurs conditions optimales d'emploi et sur les précautions d'exploitation quantitative des chromatogrammes obtenus. Des essais de répétabilité et de reproductibilité ont été réalisés sur différentes coupes de produits lourds. La qualité des résultats obtenus a conduit à une tentative de normalisation de la méthode au sein du Bureau de Normalisation du Pétrole. This article reports on the research done by a GEC (Groupe d'Etudes Concertées committee made up of scientists from the Institut Français du Pétrole (IFP, Compagnie Française de Raffinage (CFR and Société Nationale Elf Aquitaine (Production (SNEA(P who worked on joint research on heavy petroleum fractions. A gas chromatography method is described wich leads to characterize heavy cuts (370-535°C obtained by the vacuum distillation of atmospherie residues, by the simulated distillation curve. Detailed operating instructions are given, including specific recommendations for preparing and conditioning columns, optimum operating conditions, and precautions for the quantitative use of chromatograms. Repeatability and reproducibility tests were performed on several heavy cuts by four independent laboratories. The quality of the results obtained led to an attempt to have the method standardized by the Bureau de Normalisation du Pétrole.

  12. A soil-column gas chromatography (SCGC) approach to explore the thermal desorption behavior of hydrocarbons from soils.

    Science.gov (United States)

    Yu, Ying; Liu, Liang; Shao, Ziying; Ju, Tianyu; Sun, Bing; Benadda, Belkacem

    2016-01-01

    A soil-column gas chromatography approach was developed to simulate the mass transfer process of hydrocarbons between gas and soil during thermally enhanced soil vapor extraction (T-SVE). Four kinds of hydrocarbons-methylbenzene, n-hexane, n-decane, and n-tetradecane-were flowed by nitrogen gas. The retention factor k' and the tailing factor T f were calculated to reflect the desorption velocities of fast and slow desorption fractions, respectively. The results clearly indicated two different mechanisms on the thermal desorption behaviors of fast and slow desorption fractions. The desorption velocity of fast desorption fraction was an exponential function of the reciprocal of soil absolute temperature and inversely correlated with hydrocarbon's boiling point, whereas the desorption velocity of slow desorption fraction was an inverse proportional function of soil absolute temperature, and inversely proportional to the log K OW value of the hydrocarbons. The higher activation energy of adsorption was found on loamy soil with higher organic content. The increase of carrier gas flow rate led to a reduction in the apparent activation energy of adsorption of slow desorption fraction, and thus desorption efficiency was significantly enhanced. The obtained results are of practical interest for the design of high-efficiency T-SVE system and may be used to predict the remediation time. PMID:26335523

  13. Methods of Analysis - Determination of Pyrethroid Insecticides in Water and Sediment Using Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Hladik, Michelle L.; Smalling, Kelly L.; Kuivila, Kathryn M.

    2009-01-01

    A method for the determination of 14 pyrethroid insecticides in environmental water and sediment samples is described. The method was developed by the U.S. Geological Survey in response to increasing concern over the effects of pyrethroids on aquatic organisms. The pyrethroids included in this method are ones that are applied to many agricultural and urban areas. Filtered water samples are extracted for pyrethroids using solid-phase extraction (SPE) with no additional cleanup steps. Sediment and soil samples are extracted using a microwave-assisted extraction system, and the pyrethroids of interest are separated from co-extracted matrix interferences by passing the extracts through stacked graphitized carbon and alumina SPE cartridges, along with the use of high-performance liquid chromatography and gel-permeation chromatography (HPLC/GPC). Quantification of the pyrethroids from the extracted water and sediment samples is done using gas chromatography with mass spectrometry (GC/MS) or gas chromatography with tandem mass spectrometry (GC/MS/MS). Recoveries in test water samples fortified at 10 ng/L ranged from 83 to 107 percent, and recoveries in test sediment samples fortified at 10 ug/kg ranged from 82 to 101 percent; relative standard deviations ranged from 5 to 9 percent in the water samples and 3 to 9 percent in the sediment samples. Method detection limits (MDLs), calculated using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), in water ranged from 2.0 to 6.0 ng/L using GC/MS and 0.5 to 1.0 ng/L using GC/MS/MS. For sediment, the MDLs ranged from 1.0 to 2.6 ug/kg dry weight using GC/MS and 0.2 to 0.5 ug/kg dry weight using GC/MS/MS. The matrix-spike recoveries for each compound, when averaged for 12 environmental water samples, ranged from 84 to 96 percent, and when averaged for 27 environmental sediment samples, ranged from 88 to 100 percent.

  14. Miniaturized GC/MS instrumentation for in situ measurements: micro gas chromatography coupled with miniature quadrupole array and paul ion trap mass spectrometers

    Science.gov (United States)

    Holland, P.; Chutjian, A.; Darrach, M.; Orient, O.

    2002-01-01

    Miniaturized chemical instrumentation is needed for in situ measurements in planetary exploration and other spaceflight applications where factors such as reduction in payload requirements and enhanced robustness are important. In response to this need, we are 'continuing to develop miniaturized GC/MS instrumentation which combines chemical separations by gas chromatography (GC) with mass spectrometry (MS) to provide positive identification of chemical compounds in complex mixtures of gases, such as those found in the International Space Station's cabin atmosphere. Our design approach utilizes micro gas chromatography components coupled with either a miniature quadrupole mass spectrometer array (QMSA) or compact, high-resolution Paul ion trap.

  15. Estimation of the uncertainty associated with the results based on the validation of chromatographic analysis procedures: application to the determination of chlorides by high performance liquid chromatography and of fatty acids by high resolution gas chromatography.

    Science.gov (United States)

    Quintela, M; Báguena, J; Gotor, G; Blanco, M J; Broto, F

    2012-02-01

    This article presents a model to calculate the uncertainty associated with an analytical result based on the validation of the analysis procedure. This calculation model is proposed as an alternative to commonly used bottom-up and top-down methods. This proposal is very advantageous as the validation of the procedures and the estimation of the uncertainty of the measurement are part of the technical requirements needed in order to obtain the ISO 17025:2005 accreditation. This model has been applied to the determination of chloride by liquid chromatography in lixiviates and in the determination of palmitic acid and stearic acid by gas chromatography in magnesium stearate samples. PMID:22227361

  16. Impurity analyses of high-purity carbon monoxide gas using micro gas chromatography for development as a certified reference material.

    Science.gov (United States)

    Matsumoto, Nobuhiro; Watanabe, Takuro; Kato, Kenji

    2013-03-22

    High-purity carbon monoxide (CO) gas as a certified reference material (CRM) was analyzed using a micro gas chromatograph (micro-GC) with a micro thermal conductivity detector. The main reason to select the micro-GC was its compact size to provide a safe experimental environment. Thus, both the CO gas cylinder and the micro-GC were placed inside a draft shield with a limited small space. Peaks of several impurities were found in chromatograms of the micro-GC. The main impurities in the CO gas were helium, hydrogen, oxygen, nitrogen and carbon dioxide. It was found that helium was the impurity of the highest concentration. High-accuracy calibration gas mixtures were used to construct calibration lines for the micro-GC. The mixtures were precisely prepared by the gravimetric blending method. Calibration lines had enough linearity and accuracy for quantitative analyses of the impurities. The values of detection limit of the impurities were 0.7-4μmol/mol. The purity of the high-purity CO gas was around 99.996%, which was the value estimated from the sum of the concentrations of the impurities. PMID:23415447

  17. Supercooled liquid vapour pressures and related thermodynamic properties of polycyclic aromatic hydrocarbons determined by gas chromatography

    NARCIS (Netherlands)

    J.J.H. Haftka; J.R. Parsons; H.A.J. Govers

    2006-01-01

    A gas chromatographic method using Kovats retention indices has been applied to determine the liquid vapour pressure (P-i), enthalpy of vaporization (Delta H-i) and difference in heat capacity between gas and liquid phase (Delta C-i) for a group of polycyclic aromatic hydrocarbons (PAHs). This group

  18. 三通道气相色谱法测定炼厂气组成%Determination of Refinery Gas by Three-Channel Gas Chromatography

    Institute of Scientific and Technical Information of China (English)

    原雯

    2012-01-01

    炼厂气是炼油工艺产生的各种气体的混合物,采用四阀六柱将炼厂气分离分解为3部分,以双TCD+FID检测器3通道气相色谱法快速分析炼厂气.FID通道用于分析烃类,一个TCD通道分析永久性气体和硫化物,另一个TCD通道分析氢气,采用面积归一化法定量计算分析结果.用该法测定了3种标准气体,测定值与标准值基本一致,测定结果的相对标准偏差小于8%.该法适用于测定包括液化气、烟气、裂解气等组分相近的样品组成.%Refinery gas is a mixture of gases produced by the refining process, which was separated by four valve six columns and determined by two TCD+FID detector three-channel gas chromatography, FID channel was used to determine hydrocarbon, one TCD channel was used to determine permanent gas and sulfide, another TCD channel was used to determine hydrogen. The determination results was caculated by area normalization method. The determination results of 3 standard gas by this method agreed with its standard values. The RSDs of determination results were less than 8%(n=6). The method is suitable for the determination of liquefied natural gas, smoke, cracking gas and other similar components of samples.

  19. [Comparison of the performances of gas chromatography-quadrupole time of flight mass spectrometry and gas chromatography-tandem mass spectrometry in rapid screening and confirmation of 208 pesticide residues in fruits and vegetables].

    Science.gov (United States)

    Cao, Xinyue; Pang, Guofang; Jin, Linghe; Kang, Jian; Hu, Xueyan; Chang, Qiaoying; Wang, Minglin; Fan, Chunlin

    2015-04-01

    The performances of gas chromatography-tandem mass spectrometry (GC-MS/MS) and gas chromatography quadrupole time of flight mass spectrometry (GC-QTOF/MS) for the determination of 208 pesticide residues in fruit and vegetable samples, including apple, orange, tomato and cucumber, were compared comprehensively. Based on the differences of the two instruments, their respective characteristics and scopes of application in the detection of the pesticide residues were presented, which provided the reference for the analysis of pesticide residues. The performance parameters of the two instruments, such as overall recoveries, precisions, limits of detection, linear ranges, identification points and matrix effects, were evaluated according to a designed experiment. At three spiked levels (5.0, 10.0 and 20.0 µg/kg), the average recoveries for the majority of pesticides (93.0%) ranged from 70% to 120% in the four matrices with relative standard deviations below 20%. The limits of detection for most of the pesticides by GC-MS/MS and GC-Q-TOF/MS were less than 5.0 µg/kg. Compared with GC-QTOF/MS, GC-MS/MS showed relatively lower limits of detection and wider linear ranges, and its performance was more satisfactory in accurate quantitative analysis due to its superior sensitivity. On the other hand, GC-QTOF/MS provided accurate mass measurement, which was proved to be an efficient analytical tool on the rapid screening and confirmation of a large number of pesticides and non-target compounds. PMID:26292409

  20. Fingerprinting and source identification of an oil spill in China Bohai Sea by gas chromatography-flame ionization detection and gas chromatography-mass spectrometry coupled with multi-statistical analyses.

    Science.gov (United States)

    Sun, Peiyan; Bao, Mutai; Li, Guangmei; Wang, Xinping; Zhao, Yuhui; Zhou, Qing; Cao, Lixin

    2009-01-30

    This paper describes a case study in which advanced chemical fingerprinting and data interpretation techniques were used to characterize the chemical composition and determine the source of an unknown spilled oil reported on the beach of China Bohai Sea in 2005. The spilled oil was suspected to be released from nearby platforms. In response to this specific site investigation need, a tiered analytical approach using gas chromatography-mass spectrometry (GC-MS) and gas chromatography-flame ionization detection (GC-FID) was applied. A variety of diagnostic ratios of "source-specific marker" compounds, in particular isomers of biomarkers, were determined and compared. Several statistical data correlation analysis methods were applied, including clustering analysis and Student's t-test method. The comparison of the two methods was conducted. The comprehensive analysis results reveal the following: (1) The oil fingerprinting of three spilled oil samples (S1, S2 and S3) positively match each other; (2) The three spilled oil samples have suffered different weathering, dominated by evaporation with decrease of the low-molecular-mass n-alkanes at different degrees; (3) The oil fingerprinting profiles of the three spilled oil samples are positive match with that of the suspected source oil samples C41, C42, C43, C44 and C45; (4) There are significant differences in the oil fingerprinting profiles between the three spilled oil samples and the suspected source oil samples A1, B1, B2, B3, B4, C1, C2, C3, C5 and C6.

  1. Determination of n-alkanes contamination in soil samples by micro gas chromatography functionalized by multi-walled carbon nanotubes.

    Science.gov (United States)

    Li, Yubo; Zhang, Runzhou; Wang, Tao; Wang, Yonghuan; Xu, Tianbai; Li, Lingfeng; Zhao, Weijun; Dong, Shurong; Wang, Xiaozhi; Luo, Jikui

    2016-09-01

    A new method for separation of 11 n-alkanes: octane, o-nonane, n-decane, n-undecane, n-dodecane, n-tridecane, n-tetradecane, n-pentdecne, n-hexadecath, heptadecane, n-octadecane in soil samples was developed. Kuderna-Danish (K.D.) concentrator enrichment prior to ultrasonic extraction and the silicone chromatography column purification and with gas chromatography flame ionization detection (GC-FID) could be used for n-alkanes determination. The micro channels of open tubular column were fabricated onto a silicon wafer to replace the quartz capillary chromatographic column. The column structure and analysis parameters that affected the column separation were investigated and optimized. Under optimal conditions, the extract reagent was centrifuged and collected. A silicone chromatography column and a K.D. concentrator were used for further clean-up and enrichment. Using this method, the limits of detection (LOD) and limits of quantification (LOQ) were obtained in the range of 0.03-0.15 and 0.1-0.5 mg kg(-1) in soil samples, respectively. The relative standard deviation (RSD) was under 12%. The optimized procedure that presented good analytical performance (with recoveries ranging from 56.5% to 89.2%), was successfully applied to determine n-alkane content in farmland soil samples adjacent to a highway. The results showed that the MWCNTs-functionalized column is capable of separating the alkane contaminations with high resolution in about 3 min, which is much shorter than that of GC-MS and other conventional analytical methods, demonstrating its great potential for rapid analysis. PMID:27262105

  2. Determination of n-alkanes contamination in soil samples by micro gas chromatography functionalized by multi-walled carbon nanotubes.

    Science.gov (United States)

    Li, Yubo; Zhang, Runzhou; Wang, Tao; Wang, Yonghuan; Xu, Tianbai; Li, Lingfeng; Zhao, Weijun; Dong, Shurong; Wang, Xiaozhi; Luo, Jikui

    2016-09-01

    A new method for separation of 11 n-alkanes: octane, o-nonane, n-decane, n-undecane, n-dodecane, n-tridecane, n-tetradecane, n-pentdecne, n-hexadecath, heptadecane, n-octadecane in soil samples was developed. Kuderna-Danish (K.D.) concentrator enrichment prior to ultrasonic extraction and the silicone chromatography column purification and with gas chromatography flame ionization detection (GC-FID) could be used for n-alkanes determination. The micro channels of open tubular column were fabricated onto a silicon wafer to replace the quartz capillary chromatographic column. The column structure and analysis parameters that affected the column separation were investigated and optimized. Under optimal conditions, the extract reagent was centrifuged and collected. A silicone chromatography column and a K.D. concentrator were used for further clean-up and enrichment. Using this method, the limits of detection (LOD) and limits of quantification (LOQ) were obtained in the range of 0.03-0.15 and 0.1-0.5 mg kg(-1) in soil samples, respectively. The relative standard deviation (RSD) was under 12%. The optimized procedure that presented good analytical performance (with recoveries ranging from 56.5% to 89.2%), was successfully applied to determine n-alkane content in farmland soil samples adjacent to a highway. The results showed that the MWCNTs-functionalized column is capable of separating the alkane contaminations with high resolution in about 3 min, which is much shorter than that of GC-MS and other conventional analytical methods, demonstrating its great potential for rapid analysis.

  3. Structural elucidation of chemical constituents from Benincasa hispida seeds and Carissa congesta roots by gas chromatography: Mass spectroscopy

    Directory of Open Access Journals (Sweden)

    Gaurav M Doshi

    2015-01-01

    Full Text Available Background: Benincasa hispida (BH and Carissa congesta (CC are regarded as ethnopharmacological imperative plants in Asian countries. Objective: Phytochemical screening of the extracts has shown the presence of steroids, flavonoids, saponins, glycosides, tannins, phenolic compounds, fixed oils, and fats in the BH and CC extracts. The presence of lupeol has been reported previously by us using high-performance thin-layer chromatography and high-performance liquid chromatography. Materials and Methods: Present research studies encompasses identification of chemical constituents in BH seeds and CC roots petroleum ether extracts by hyphenated technique such as gas chromatography-mass spectroscopy (MS which when coupled gives a clear insight of constituents. Results: The components were identified by matching mass spectra with MS libraries. There were 13 and 10 different compounds analyzed from CC and BH, respectively. The components present were Pentanoic acid, 5-hydroxy, 2,4-butylphenyl; n-Hexadecanoic acid (Palmitic acid; Sulfurous acid, 2-ethylhexylhepatdecyl ester; n-Tridecane; 6-methyltridecane; (9E, 12E-9,12-Octadecadienyl chloride, Hexadecanoic acid, 3-(trimethylsilyl-oxy] propyl ester; 9,12-Octadecadenoic acid, 2 hydroxy-1-(hyroxymethylethyl ester; 9,12-Octadecadienoic acid, 2,3 dihydroxypropyl ester; n-Propyl-9,12-Octadecadienoate, Lupeol; Taraxasterol; 6a, 14a-Methanopicene, perhydro-12,4a, 61a, 9,9,12a-hepatmethyl-10-hydoxy and 9-Octadecene; 2-Isoprpenyl-5-methyl-6-hepten-1-ol; n-Hexadecanoic acid, 2-hyroxy-1-(hydroxymethyl ethyl ether; Butyl-9,12-Octadecadieonate; Friedoolean-8-en-3-one; friedours-7-en-3-one; 13,27-Cyclosuran-3-one; Stigmaste-7,25-dien-3-ol (3β, 5α; Stigmasta-7,16-dien-3-ol; chrondrillasterol in BH seeds and CC roots extracts respectively. Conclusion: Eluted components from the extracts could provide further researchers to work with various pharmacological activities related models and studies.

  4. 气相色谱及气相色谱-质谱法检测食品中增塑剂%Determination of Phthalates in Foods by Gas Chromatography and Gas Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    李一尘; 徐静; 董伟峰; 肖珊珊

    2012-01-01

    利用气相色谱及气相色谱-质谱联用技术,对食品中4种邻苯酸二甲酯类化合物进行检测。对于非油脂类食品,气相色谱法的检出限为1.5mg/kg,平均回收率为67.4%-92.9%,相对标准偏差为1.6%-4.7%;气相色谱-质谱联用的检出限为0.05mg/kg,平均回收率为66.3%-112.9%,相对标准偏差为2.9%-11.3%。对于油脂类食品,气相色谱法的检出限为30mg/kg,平均回收率为73.4%-96.1%,相对标准偏差为1.6%-2.8%;气相色谱-质谱联用的检出限为1.5mg/kg,平均回收率为64.1%-80.2%,相对标准偏差为1.6%-4.5%。用该分析方法对285批食品样品进行了分析检测,1批食品样品检出BBP,13批检出DBP,63批检出DEHP,总检出阳性样品68批,总阳性检出率23.9%,其检出质量分数为0.05-1.27mg/kg。该方法前处理简单,分离效果好,灵敏度高,能够满足食品中4种邻苯二甲酸酯检测的需要。%In this paper,4 phthalates(DBP,BBP,DEHP,DNOP) in the foods were determined by gas chromatography and gas chromatography-mass spectrometry.In the fat free foods with gas chromatography,the method detection limits was 1.5mg/kg,the recoveries ranged from 67.4%-92.9%,and the relative standard deviations were between 1.6% and 4.7%;with gas chromatography-mass spectrometry,the method detection limits was 0.05mg/kg,the recoveries ranged from 66.3%-112.9%,and the relative standard deviations were between 2.9% and 11.3%.In the greasy foods with gas chromatography,the method detection limits was 30mg/kg,the recoveries ranged from 73.4%-96.1%,and the relative standard deviations were between 1.6% and 2.8%;with gas chromatography-mass spectrometry,the method detection limits was 1.5mg/kg,the recoveries ranged from 64.1%-80.2%,and the relative standard deviations were between 1.6% and 4.5%.Altogether 285 pieces of food samples were detected by this method.The findings were as follows: 1 sample contained BBP,13 samples contained DBP,and 63 samples contained DEHP.The total 68 samples

  5. Multiple responses optimization in the development of a headspace gas chromatography method for the determination of residual solvents in pharmaceuticals

    Directory of Open Access Journals (Sweden)

    Carla M. Teglia

    2015-10-01

    Full Text Available An efficient generic static headspace gas chromatography (HSGC method was developed, optimized and validated for the routine determination of several residual solvents (RS in drug substance, using a strategy with two sets of calibration. Dimethylsulfoxide (DMSO was selected as the sample diluent and internal standards were used to minimize signal variations due to the preparative step. A gas chromatograph from Agilent Model 6890 equipped with flame ionization detector (FID and a DB-624 (30 m×0.53 mm i.d., 3.00 µm film thickness column was used. The inlet split ratio was 5:1. The influencing factors in the chromatographic separation of the analytes were determined through a fractional factorial experimental design. Significant variables: the initial temperature (IT, the final temperature (FT of the oven and the carrier gas flow rate (F were optimized using a central composite design. Response transformation and desirability function were applied to find out the optimal combination of the chromatographic variables to achieve an adequate resolution of the analytes and short analysis time. These conditions were 30 °C for IT, 158 °C for FT and 1.90 mL/min for F. The method was proven to be accurate, linear in a wide range and very sensitive for the analyzed solvents through a comprehensive validation according to the ICH guidelines.

  6. Multiple responses optimization in the development of a headspace gas chromatography method for the determination of residual solvents in pharmaceuticals

    Institute of Scientific and Technical Information of China (English)

    Carla M. Teglia; Milagros Montemurro; María M. De Zan; María S. Cámara

    2015-01-01

    An efficient generic static headspace gas chromatography (HSGC) method was developed, optimized and validated for the routine determination of several residual solvents (RS) in drug substance, using a strategy with two sets of calibration. Dimethylsulfoxide (DMSO) was selected as the sample diluent and internal standards were used to minimize signal variations due to the preparative step. A gas chroma-tograph from Agilent Model 6890 equipped with flame ionization detector (FID) and a DB-624 (30 m × 0.53 mm i.d., 3.00μm film thickness) column was used. The inlet split ratio was 5:1. The influ-encing factors in the chromatographic separation of the analytes were determined through a fractional factorial experimental design. Significant variables: the initial temperature (IT), the final temperature (FT) of the oven and the carrier gas flow rate (F) were optimized using a central composite design. Response transformation and desirability function were applied to find out the optimal combination of the chromatographic variables to achieve an adequate resolution of the analytes and short analysis time. These conditions were 30 °C for IT, 158 °C for FT and 1.90 mL/min for F. The method was proven to be accurate, linear in a wide range and very sensitive for the analyzed solvents through a comprehensive validation according to the ICH guidelines.

  7. Detection of endogenous ethanol and other compounds in the breath by gas chromatography with on-column concentration of sample.

    Science.gov (United States)

    Phillips, M; Greenberg, J

    1987-05-15

    A new method is described for collecting and concentrating volatile compounds in the breath, in order to facilitate their assay by gas chromatography. Breath was collected into sealed Mylar bags containing an internal standard (isopropyl alcohol). The sample was pumped through a cooled gas chromatograph column, where the volatile compounds were concentrated by adsorption onto the resin packing (Porapak Q) at 35 degrees C. The column was then heated, and the volatilized sample was separated for assay by flame ionization detection. The assay was highly sensitive for ethanol (detecting at least 4.0 nmol) and linear up to 20 nmol (r2 = 0.98). Accuracy and precision were determined by assaying nine replicates of a sample containing 12.0 nmol ethanol; a mean value of 12.18 nmol ethanol was obtained with a coefficient of variation of 10.26%. In a group of normal volunteers, endogenous breath ethanol concentrations ranged from 2.23 to 6.51 nmol/liter. This assay provided a number of advantages over previously described methods: The use of breath collection bags enabled the collection of samples outside the laboratory. The use of an internal standard in the collection bag reduced errors that might have resulted from leakage of the specimen. An on-column concentration of the sample in the gas chromatograph eliminated the need for an additional preconcentration device, such as a cryogenic or adsorptive trapping apparatus.

  8. A practical gas chromatography flame ionization detection method for the determination of octamethylcyclotetrasiloxane, decamethylcyclopentasiloxane, and dodecamethylcyclohexasiloxane in silicone emulsions.

    Science.gov (United States)

    Brothers, Herbert M; Bovens, Eric; Bruni, Antonio; Habitz, Tanya M; Hamachi, Tadashi; Han, Yuanhua; Ji, Zhouhua; Kerbleski, Joel J; Letouche, Claude; Lu, Yi Dong; Nguyen, Regis; Rivard, Michelle L; Qi, Xiaoman; Shoji, Miki; Tanaka, Ken; Tecklenburg, Ronald E

    2016-04-01

    A gas chromatography with flame ionization detection (GC-FID) method for analysis of D4, D5, and D6 cyclic siloxanes in silicone emulsions is described. Sample preparation involves breaking the emulsion with methanol and hexanes, and then analyzing the hexanes phase after derivatization with hexamethyldisilazane (HMDS). Silylation is performed to reduce the potential for formation of cyclic siloxanes during the course of the GC analysis. The accuracy of the method was verified by performing analyses on samples spiked with known levels of D4, D5 and D6 and by comparison to a referee method using atmospheric pressure chemical ionization liquid chromatography with mass spectrometry detection (APCI-LC-MS). Absolute differences of the results obtained between the two techniques were 0.03 weight percent or less, and relative differences were 15% or less. The reproducibility and ruggedness of the method was demonstrated by performing a global round robin test at four different geographic sites on four different types of silicone emulsions. The %RSDs obtained were less than 10% for all analytes and all emulsions examined. PMID:26968230

  9. Isothermal gas chromatography of chlorides of Zr and Hf as Rf homologs

    International Nuclear Information System (INIS)

    An isothermal chromatographic apparatus was developed for the on-line experiments of super heavy elements in gas phase. As a model of Rf, we investigated the gas phase chemistry of Zr and Hf chlorides. The dependence of the reaction efficiency on temperature was examined. It was found that about 80% of Zr and Hf reacted with chlorinating gas at 900 deg C. Adsorption enthalpies of Zr and Hf chlorides were deduced from the isothermal chromatograph by the Monte Carlo simulation based on the microscopic model proposed by Zvara. (author)

  10. Analytical Method Validation of Selected Organochlorine Pesticides in Fortified Rice Using Gas Chromatography with Electron Capture Detector

    Directory of Open Access Journals (Sweden)

    Mutia Kusuma Wardani

    2014-01-01

    Full Text Available Gas chromatography with electron capture detector (GC-ECD has been validated for simultaneous determination of selected organochlorine pesticides namely heptachlor, endosulfan, dieldrin, dan p,p’-dichlorodiphenyltrichloroethane (p,p’-DDT using aldrin as standard internal. Some parameters for analytical method validation were evaluated, i.e. linearity, precision, sensitivity expressed with limit of detection and limit of quantification, and recovery. GC-ECD was linear for determination of these pesticides with r values ≥ 0.99. The values of LOD obtained were 2.50, 2.97, 1.61, and 2.54 ng/mL for heptachlor, endosulphan, dieldrin, and p,p’-DDT, respectively. Furthermore, the relative standard deviation (RSD values obtained for the assessment of analytical precision were lower than those required by Horwitz. Finally, the used GC-ECD method was accurate for determination of these organochlorine psticides in fortified rice samples which were indicated by the acceptable recovery percentages.

  11. Prediction of the wine sensory properties related to grape variety from dynamic-headspace gas chromatography-olfactometry data.

    Science.gov (United States)

    Campo, Eva; Ferreira, Vicente; Escudero, Ana; Cacho, Juan

    2005-07-13

    Wine extracts obtained by a dynamic headspace sampling technique were studied by quantitative gas chromatography-olfactometry (GC-O) to determine the aroma profiles of six young monovarietal Spanish white wines. A partial least-square regression study was carried out to look for models relating wine aroma properties with GC-O scores. Models were validated by sensory analysis. Four out of the five most important sensory descriptors were satisfactorily described by a model, and sensory tests confirmed most of the predictions. The main aroma differences between these wines are due to the ratio linalool/3-mercaptohexyl acetate. Floral, sweet, and muscat are positively related to the concentration of linalool and negatively to that of 3-mercaptohexyl acetate. Tropical fruit is related to the wine content in this last odorant. 2-Phenyl acetate, reinforced by other acetates, can also contribute to floral and sweet notes. Alkyl-methoxypyrazines lessen the tropical fruit note, and acetic acid lessens the muscat nuance.

  12. Identification and Discrimination of Brands of Fuels by Gas Chromatography and Neural Networks Algorithm in Forensic Research

    Science.gov (United States)

    Ugena, L.; Moncayo, S.; Manzoor, S.; Rosales, D.

    2016-01-01

    The detection of adulteration of fuels and its use in criminal scenes like arson has a high interest in forensic investigations. In this work, a method based on gas chromatography (GC) and neural networks (NN) has been developed and applied to the identification and discrimination of brands of fuels such as gasoline and diesel without the necessity to determine the composition of the samples. The study included five main brands of fuels from Spain, collected from fifteen different local petrol stations. The methodology allowed the identification of the gasoline and diesel brands with a high accuracy close to 100%, without any false positives or false negatives. A success rate of three blind samples was obtained as 73.3%, 80%, and 100%, respectively. The results obtained demonstrate the potential of this methodology to help in resolving criminal situations. PMID:27375919

  13. Determination of Chlorophenols in Water Samples Using Solid-Phase Extraction Enrichment Procedure and Gas Chromatography Analysis.

    Science.gov (United States)

    Ben Hassine, S; Hammami, B; Touil, S; Driss, M R

    2015-11-01

    Solid-phase extraction (SPE) procedure followed by derivatization and gas chromatography electron capture detection was evaluated for the determination of trace amounts of chlorophenols (CPs) in waters samples. Different parameters affecting extraction efficiency such as, volume of elution solvent, volume and pH of water sample, quantity of sorbent phase were studied and optimized. SPE was carried out on polystyrene-divinylbenzene (Bond Elut ENV) and high recoveries were obtained using 1000 mg of this cartridge for the treatment of 500 mL of acidified water sample. The described method was then tested on spiked tap, mineral, ground and surface water samples. The overall procedure provided limits of detection lower than 20 ng L(-1), recoveries of 70%-106% and an enrichment factor of 500 for the examined CPs in 500 mL water samples. Among the studied compounds, pentachlorophenol was detected in tap water at a concentration level of 0.06 µg L(-1). PMID:26067701

  14. Detection of lysergic acid diethylamide (LSD) in urine by gas chromatography-ion trap tandem mass spectrometry.

    Science.gov (United States)

    Sklerov, J H; Kalasinsky, K S; Ehorn, C A

    1999-10-01

    A confirmatory method for the detection and quantitation of lysergic acid diethylamide (LSD) is presented. The method employs gas chromatography-tandem mass spectrometry (GC-MS-MS) using an internal ionization ion trap detector for sensitive MS-MS-in-time measurements of LSD extracted from urine. Following a single-step solid-phase extraction of 5 mL of urine, underivatized LSD can be measured with limits of quantitation and detection of 80 and 20 pg/mL, respectively. Temperature-programmed on-column injections of urine extracts were linear over the concentration range 20-2000 pg/mL (r2 = 0.999). Intraday and interday coefficients of variation were LSD-positive samples in this laboratory. Comparisons with alternate GC-MS methods and extraction procedures are discussed.

  15. Comparative analysis of essential oils found in Rhizomes Curcumae and Radix Curcumae by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Di-Ya Lu; Yan Cao; Ling Li; Zhen-Yu Zhu; Xin Dong; Hai Zhang; Yi-Feng Chai; Zi-Yang Lou

    2011-01-01

    A comparison of the volatile compounds in Rhizomes Curcumae (Ezhu) and Radix Curcumae (Yujin) was undertaken using gas chromatography mass spectrometi-y (GC-MS). Ultrasonic extraction and GC-MS methods were developed for the simultaneous determination of five sesquiterpenes, namely, α-pinene, β-elemene, curcumol, germacrone and curdione, in Ezhu and Yunjin. Good linearity (r〉0.999) and high inter-day precision were observed over the investigated concentration ranges. The validated method was successfully used for the simultaneous determination of five sesquiterpenes in Ezhu and Yujin. The quantitative method can be effectively used to evaluate and monitor the quality of Chinese curcuma in clinical use.

  16. Analysis of volatile components in a Chinese fish sauce,Fuzhou Yulu, by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Yuan-fan YANG; Shen-ru CHEN; Hui NI; Xing-qian YE

    2008-01-01

    Volatile components of Fuzhou Yulu, a Chinese fish sauce, were analyzed by gas chromatography-mass spectrometry (GC-MS), and two pretreatment methods, i.e., purge and trap (P&T) GC-MS and ethyl acetate extraction followed by GC-MS, were compared. P&T-GC-MS method determined 12 components, including sulfur-containing constituents (such as dimethyl disulfide), nitrogen-containing constituents (such as pyrazine derivatives), aldehydes and ketones. Ethyl ace tate extraction fol-lowed by GC-MS method detected 10 components, which were mainly volatile organic acids (such as benzenepropanoic acid) and esters. Neither of the two methods detected alcohols or trimethylamine. This study offers an important reference to determine volatile flavor components of traditional fish sauce through modem analysis methods.

  17. Determination of polycyclic aromatic hydrocarbons in urban street dusts and their source materials by capillary gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Takada, Hideshige; Onda, Tomoko; Ogura, Norio (Tokyo Univ. of Agriculture and Technology (Japan))

    1990-08-01

    Molecular distributions of polycyclic aromatic hydrocarbons (PAHs) in street dust samples collected from the Tokyo metropolitan area were determined by capillary gas chromatography following HPLC fractionation. Sixty-four compounds including three- to six-ring PAHs and sulfur heterocyclics were identified by capillary GC/MS. Total PAH concentrations were in the range of a few micrograms per gram of dust. The source materials (automobile exhaust, asphalt, fuel-oil combustion products) were also analyzed. The PAH profile, especially relative abundance of alkyl-PAHs and sulfur-containing heterocyclics, indicated that PAHs in the street dusts on the heavily trafficked streets are strongly affected by automobile exhaust and those in the residential area have a somewhat more significant contribution from combustion products in stationary sources. With both types of dusts, asphalt is through to contribute only a minor part of their PAHs.

  18. Application of Gas Chromatography-mass Spectrometry in Analyzing Pharmacokinetics and Distribution of Deltamethrin in Miniature Pig Tissues

    Institute of Scientific and Technical Information of China (English)

    ZHU Pan; FAN Sai; ZOU Jian Hong; MIAO Hong; LI Jing Guang; ZHANG Guo Wen; WU Yong Ning

    2014-01-01

    Objective To characterize the pharmacokinetics and distribution profiles of deltamethrin in miniature pig tissues by gas chromatography-mass spectrometry (GC-MS). Methods Pharmacokinetics and distribution of deltamethrin in blood and tissues of 30 miniature pigs were studied by GC-MS after oral administration of deltamethrin (5 mg/kg bw). Data were processed by 3P97 software. Results The serum deltamethrin level was significantly lower in tissues than in blood of miniature pigs. The AUC0-72 h, Cmax, of deltamethrin were 555.330±316.987 ng h/mL and 17.861±11.129 ng/mL, respectively. The Tmax, of deltamethrin was 6.004±3.131 h. Conclusion The metabolism of deltamethrin in miniature pigs is fit for a one-compartment model with a weighting function of 1/C2. Deltamethrin is rapidly hydrolyzed and accumulated in miniature pig tissues.

  19. Analysis of volatile chemical components of Radix Paeoniae Rubra by gas chromatography-mass spectrometry and chemometric resolution

    Institute of Scientific and Technical Information of China (English)

    LI Xiao-ru; LAN Zheng-gang; LIANG Yi-zeng

    2007-01-01

    The volatile chemical components of Radix Paeoniae Rubra (RPR) were analyzed by gas chromatography-mass spectrometry with the method of heuristic evolving latent projections and overall volume integration.The results show that 38 volatile chemical components of RPR are determined.accounting for 95.21% of total contents of volatile chemical components of RPR.The main volatile chemical components of RPR are(Z,Z)-9, 12-octadecadienoic acid, n-hexadecanoic acid, 2-hydroxy benzaldehyde, 1-(2-hydroxy-4-methoxyphenyl)-ethanone, 6,6-dimethyl-bicyclo[3.1.1]heptane-2-methanol, 4,7-dimethyl-benzofuran, 4-(1-methylethenyl)-1-cyclohexene-1-carboxaldehyde, and cyclohexadecane.

  20. The application of gas chromatography fingerprint technique to calculating oil production allocation of single layer in the commingled well

    Institute of Scientific and Technical Information of China (English)

    WEN Zhigang; ZHU Dan; TANG Youjun; LI Yuquan; ZHANG Guorong

    2005-01-01

    Gas chromatography fingerprint technique has the advantages of fast performance and low cost. It can be used to conduct analysis without interruption either in the field or at laboratory. This technique has been used successfully in such cases that conventional production logging techniques are powerless. Taking low-concentration anthracene as internal standard, we calculated the absolute concentrations of fingerprints, initially made some experiments directly on biodegradation of crude oils, and calculated production allocation in the Gudong Oil field. Compared with the production logging, this method has made up for the deficiencies of the former GC fingerprint technique. It will find wide applications in monitoring the trend of production in various oil-fields.