  1. Determination of trimethyllead reference material using high performance liquid chromatography-inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Lu Hai; Wei Chao; Wang Jun; Chao Jingbo; Zhou Tao; Chen Dazhou

    2005-01-01

    A high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) was combined, and the chromatography conditions were optimized. The stability and homogeneity of a trimethyllead reference material were determined using this method. (authors)

  2. Multimodal charge-induction chromatography for antibody purification.

    Science.gov (United States)

    Tong, Hong-Fei; Lin, Dong-Qiang; Chu, Wen-Ning; Zhang, Qi-Lei; Gao, Dong; Wang, Rong-Zhu; Yao, Shan-Jing

    2016-01-15

    Hydrophobic charge-induction chromatography (HCIC) has advantages of high capacity, salt-tolerance and convenient pH-controlled elution. However, the binding specificity might be improved with multimodal molecular interactions. New ligand W-ABI that combining tryptophan and 5-amino-benzimidazole was designed with the concept of mutimodal charge-induction chromatography (MCIC). The indole and benzimidazole groups of the ligand could provide orientated mutimodal binding to target IgG under neutral pH, while the imidazole groups could induce the electrostatic repulsion forces for efficient elution under acidic pH. W-ABI ligand was coupled successfully onto agarose gel, and IgG adsorption behaviors were investigated. High affinity to IgG was found with the saturated adsorption capacity of 70.4 mg/ml at pH 7, and the flow rate of mobile phase showed little impact on the dynamic binding capacity. In addition, efficient elution could be achieved at mild acidic pH with high recovery. Two separation cases (IgG separation from albumin containing feedstock and monoclonal antibody purification from cell culture supernatant) were verified with high purity and recovery. In general, MCIC with the specially-designed ligand is an expanding of HCIC with improved adsorption selectivity, which would be a potential alternative to Protein A-based capture for the cost-effective purification of antibodies. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Multielement determination of rare earth elements in rock sample by liquid chromatography / inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Hamanaka, Tadashi; Itoh, Akihide; Itoh, Shinya; Sawatari, Hideyuki; Haraguchi, Hiroki.

    1995-01-01

    Rare earth elements in geological standard rock sample JG-1 (granodiolite)issued from the Geological Survey of Japan have been determined by a combined system of liquid chromatography and inductively coupled plasma mass spectrometry. (author)

  4. Coupling nanoliter high-performance liquid chromatography to inductively coupled plasma mass spectrometry for arsenic speciation.

    Science.gov (United States)

    Cheng, Heyong; Shen, Lihuan; Liu, Jinhua; Xu, Zigang; Wang, Yuanchao

    2018-04-01

    Nanoliter high-performance liquid chromatography shows low consumption of solvents and samples, offering one of the best choices for arsenic speciation in precious samples in combination with inuctively coupled plasma mass spectrometry. A systematic investigation on coupling nanoliter high-performance liquid chromatography to inductively coupled plasma mass spectrometry from instrument design to injected sample volume and mobile phase was performed in this study. Nanoflow mobile phase was delivered by flow splitting using a conventional high-pressure pump with reuse of mobile phase waste. Dead volume was minimized to 60 nL for the sheathless interface based on the previously developed nanonebulizer. Capillary columns for nanoliter high-performance liquid chromatography were found to be sensitive to sample loading volume. An apparent difference was also found between the mobile phases for nanoliter and conventional high-performance liquid chromatography. Baseline separation of arsenite, arsenate, monomethylarsenic, and dimethylarsenic was achieved within 11 min on a 15 cm C 18 capillary column and within 12 min on a 25 cm strong anion exchange column. Detection limits of 0.9-1.8 μg/L were obtained with precisions variable in the range of 1.6-4.2%. A good agreement between determined and certified values of a certified reference material of human urine (GBW 09115) validated its accuracy along with good recoveries (87-102%). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Chromatography.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  6. Multielement determination of rare earth elements by liquid chromatography/inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Sawatari, Hideyuki; Asano, Takaaki; Hu, Xincheng; Saizuka, Tomoo; Itoh, Akihide; Hirose, Akio; Haraguchi, Hiroki

    1995-01-01

    The rapid determination of rare earth elements (REEs) has been investigated by an on-line system of high performance liquid chromatography/multichannel inductively coupled plasma atomic emission spectrometry. In the present system, all REEs could be detected simultaneously in a single chromatographic measurement without spectral interferences. Utilizing a cation exchange column and 2-hydroxy-2-methylpropanoic acid aqueous solution as the mobile phase, the detection limits of 0.4-30 ng ml -1 for all REEs were obtained. The system was applied to the determination of REEs in geological standard rock samples and rare earth impurities in high purity rare earth oxides. The REEs in standard rocks could be determined by the present HPLC/ICP-AES system without pretreatment after acid digestion, although the detection limits were not sufficient for the analysis of rare earth oxides. (author)

  7. Determination of rare earth elements by liquid chromatography/inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Yoshida, K.; Haraguchi, H.

    1984-01-01

    Inductively coupled plasma atomic emission spectrometry (ICP-AES) interfaced with high-performance liquid chromatography (HPLC) has been applied to the determination of rare earth elements. ICP-AES was used as an element-selective detector for HPLC. The separation of rare earth elements with HPLC helped to avoid erroneous analytical results due to spectral interferences. Fifteen rare earth elements (Y and 14 lanthanides) were determined selectively with the HPLC/ICP-AES system using a concentration gradient method. The detection limits with the present HPLC/ICP-AES system were about 0.001-0.3 μg/mL with a 100-μL sample injection. The calibration curves obtained by the peak height measurements showed linear relationships in the concentration range below 500 μg/mL for all rare earth elements. A USGS rock standard sample, rare earth ores, and high-purity lanthanide reagents (>99.9%) were successfully analyzed without spectral interferences

  8. Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Douglas C., E-mail: douglas.baxter@alsglobal.com [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Faarinen, Mikko [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Osterlund, Helene; Rodushkin, Ilia [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Division of Geosciences, Lulea University of Technology, 977 87 Lulea (Sweden); Christensen, Morten [ALS Scandinavia AB, Maskinvaegen 2, 183 53 Taeby (Sweden)

    2011-09-09

    Highlights: {center_dot} We determine methylmercury in serum and plasma using isotope dilution calibration. {center_dot} Separation by gas chromatography and detection by inductively coupled plasma mass spectrometry. {center_dot} Data for 50 specimens provides first reference range for methylmercury in serum. {center_dot} Serum samples shown to be stable for 11 months in refrigerator. - Abstract: A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with {sup 198}Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) {mu}g L{sup -1} could be performed with uncertainty amplification factors <2. A limit of quantification of 0.03 {mu}g L{sup -1} was estimated at 10 times the standard deviation of concentrations measured in preparation blanks. Within- and between-run relative standard deviations were <10% at added concentration levels of 0.14 {mu}g L{sup -1}, 0.35 {mu}g L{sup -1} and 2.8 {mu}g L{sup -1}, with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; <0.03-0.19) {mu}g L{sup -1}. This is the first time methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.

  9. Determination of Dibutyltin in Sediments Using Isotope Dilution Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

    International Nuclear Information System (INIS)

    Yim, Yong Hyeon; Park, Ji Youn; Han, Myung Sub; Park, Mi Kyung; Kim, Byung Joo; Lim, Young Ran; Hwang, Eui Jin; So, Hun Young

    2005-01-01

    A method is described for the determination of dibutyltin (DBT) in sediment by isotope dilution using liquid chromatography inductively-coupled plasma/mass spectrometry (LC-ICP/MS). To achieve the highest accuracy and precision, special attentions are paid in optimization and evaluation of overall processes of the analysis including extraction of analytes, characterization of the standards used for calibration and LC-ICP/MS conditions. An approach for characterization of natural abundance DBT standard has been developed by combining inductively-coupled plasma/optical emission spectrometry (ICP/OES) and LC-ICP/MS for the total Sn assay and the analysis of Sn species present as impurities, respectively. An excellent LC condition for separation of organotin species was found, which is suitable for simultaneous DBT and tributyltin (TBT) analysis as well as impurity analysis of DBT standards. Microwave extraction condition was also optimized for high efficiency while preventing species transformation. The present method determines the amount contents of DBT in sediments with expanded uncertainty of less than 5% and its result shows high degree of equivalence with reference values of an international inter-comparison and a certified reference material (CRM) within stated uncertainties

  10. Determination of Dibutyltin in Sediments Using Isotope Dilution Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Yong Hyeon; Park, Ji Youn; Han, Myung Sub; Park, Mi Kyung; Kim, Byung Joo; Lim, Young Ran; Hwang, Eui Jin; So, Hun Young [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2005-03-15

    A method is described for the determination of dibutyltin (DBT) in sediment by isotope dilution using liquid chromatography inductively-coupled plasma/mass spectrometry (LC-ICP/MS). To achieve the highest accuracy and precision, special attentions are paid in optimization and evaluation of overall processes of the analysis including extraction of analytes, characterization of the standards used for calibration and LC-ICP/MS conditions. An approach for characterization of natural abundance DBT standard has been developed by combining inductively-coupled plasma/optical emission spectrometry (ICP/OES) and LC-ICP/MS for the total Sn assay and the analysis of Sn species present as impurities, respectively. An excellent LC condition for separation of organotin species was found, which is suitable for simultaneous DBT and tributyltin (TBT) analysis as well as impurity analysis of DBT standards. Microwave extraction condition was also optimized for high efficiency while preventing species transformation. The present method determines the amount contents of DBT in sediments with expanded uncertainty of less than 5% and its result shows high degree of equivalence with reference values of an international inter-comparison and a certified reference material (CRM) within stated uncertainties.

  11. Arsenic speciation in soil using high performance liquid chromatography/inductively coupled plasma/mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Bass, D.A.; Yaeger, J.S.; Parish, K.J.; Crain, J.S.; Kiely, J.T.; Gowdy, M.J. [Argonne National Lab., IL (United States); Mohrman, G.B.; Besmer, M.G. [Rocky Mountain Arsenal, Commerce City, CO (United States)

    1996-08-01

    A method has been developed to identify and quantify As(III), As(V), and organoarsenic compounds in soil samples from the Rocky Mountain Arsenal (RMA) by high performance liquid chromatography/inductively coupled plasma/mass spectrometry (HPLC/ICP/MS). The soils were extracted using tetrabutylammonium hydroxide (TBAH) and sonication. The percentages of As(III), As(V), and organoarsenic species extracted from soil samples were 30, 50, and 100 respectively. The arsenic species were not altered during the extraction process. They were separated by reversed-phase, ion-pairing, HPLC using a microbore Inertsil-ODS{trademark} column. The HPLC column effluent was introduced into an ICP/MS system using a direct injection nebulizer (DIN). Detection limits of less than 1 pg were readily obtained for each arsenic species. Internal standards are recommended to increase accuracy and precision. Soil samples spiked with arsenic oxide, sodium arsenate, dimethylarsinic acid (DMAA), and chlorovinyl arsenious acid (CVAA) were extracted, identified and quantified with the HPLC/ICP/MS system. The soil samples were analyzed in support of the analytical needs of a thermal desorption treatability study being conducted at the RMA.

  12. Cobalamin speciation using reversed-phase micro-high-performance liquid chromatography interfaced to inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Yanes, Enrique G.; Miller-Ihli, Nancy J.

    2004-01-01

    Micro-high-performance liquid chromatography interfaced to inductively coupled plasma mass spectrometry was optimized for the determination and separation of a mixture of cobalt containing species. Four cobalamin species (cyanocobalamin, hydroxocobalamin, methylcobalamin, and 5'-deoxyadenosylcobalamin) representing the various forms of vitamin B12 as well as the harmful corrinoid analogue cobinamide dicyanide were separated using reversed-phase microcapillary chromatography with columns containing C18 packing material with a 2-μm particle size. Selection of organic solvents for the separation took into consideration compatibility with the inductively coupled plasma mass spectrometer being used for element specific detection. Optimized method conditions included use of a methanol gradient and make-up solution for the nebulizer. Some issues associated with dead volume were overcome by the extension of the gradient program. The total analysis time was 52 min. The column-to-column variability was evaluated and was found to be very reasonable (9% RSD on average), confirming that this method is rugged and that the technology should be easily transferred to other laboratories

  13. New approach to the determination phosphorothioate oligonucleotides by ultra high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Studzińska, Sylwia; Mounicou, Sandra; Szpunar, Joanna; Łobiński, Ryszard; Buszewski, Bogusław

    2015-01-15

    This text presents a novel method for the separation and detection of phosphorothioate oligonucleotides with the use of ion pair ultra high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry The research showed that hexafluoroisopropanol/triethylamine based mobile phases may be successfully used when liquid chromatography is coupled with such elemental detection. However, the concentration of both HFIP and TEA influences the final result. The lower concentration of HFIP, the lower the background in ICP-MS and the greater the sensitivity. The method applied for the analysis of serum samples was based on high resolution inductively coupled plasma mass spectrometry. Utilization of this method allows determination of fifty times lower quantity of phosphorothioate oligonucleotides than in the case of quadrupole mass analyzer. Monitoring of (31)P may be used to quantify these compounds at the level of 80 μg L(-1), while simultaneous determination of sulfur is very useful for qualitative analysis. Moreover, the results presented in this paper demonstrate the practical applicability of coupling LC with ICP-MS in determining phosphorothioate oligonucleotides and their metabolites in serum within 7 min with a very good sensitivity. The method was linear in the concentration range between 0.2 and 3 mg L(-1). The limit of detection was in the range of 0.07 and 0.13 mg L(-1). Accuracy varied with concentration, but was in the range of 3%. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Determination of trimethylselenonium ion in urine by ion chromatography and inductively coupled plasma mass spectrometry detection

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Jessen, K.D.; Kristensen, F.H.

    2000-01-01

    The selenium species selenite, selenate, selenomethionine (SeMet), and trimethylselenonium iodide (TMSe+) were separated in aqueous solution by ion chromatography. The separation was performed on an Ionpac CS5 cation exchange column by elution with 10 mM oxalic acid and 20 mM potassium sulphate, p...

  15. Extraction of butyltins from sediments and their determination by liquid chromatography interfaced to inductively coupled plasma atomic emission detector

    International Nuclear Information System (INIS)

    Rivaro, P.; Frache, R.

    2000-01-01

    A liquid-liquid extraction of the butyltin compounds from sediment, suitable for their subsequent following determination by high performance liquid chromatography-hydride generation inductively coupled plasma atomic emission detector system, is proposed. Recoveries of 86%, 80% and 42% for tributyltin (TBT), dibutyltin (DBT) and monobutyltin (MBT) respectively were achieved. The relative detection limits of butyltin compounds by this method ranged from 27 to 62 ng of tin per gram of dry sediment. The method was applied to real sediment samples collected in the Venice lagoon (Italy). The results showed that, despite the restrictions on the use of butyltin contained in antifoulting paints, a considerable amount of organotin compounds is still present in Venice sediments [it

  16. Determination of selenite and selenate in human urine by ion chromatography and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Jons, O.

    2000-01-01

    The selenium species selenite, selenate and selenomethionine were separated in aqueous solution by ion chromatography. The separation was performed on an IonPac AG11 in series with an AS11 anion exchange column by elution with 25 mM sodium hydroxide in 2% methanol. The Se-78 and Se-82 isotopes were...... monitored in the inductively coupled plasma mass spectrometry (ICP-MS) detector. When the chromatographic system was applied to analysis of urine samples diluted 1 + 1, the selenomethionine signal appeared in the front together with other unresolved selenium species, while the selenite and selenate signals...... and selenate, respectively, corresponding to absolute amounts of 8 and 16 pg, respectively. Calculations were based on peak height measurements of the Se-82 isotope. In 23 analysed urine samples, the concentration of selenite was in the range selenium...

  17. Determination of antimony compounds in waters and juices using ion chromatography-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Lin, Ya-An; Jiang, Shiuh-Jen; Sahayam, A C

    2017-09-01

    A method was developed by coupling ion chromatography (IC) and inductively coupled plasma mass spectrometry (ICP-MS) for the speciation of antimony. In this study, antimony species such as antimonite [Sb(III)], antimonate [Sb(V)] and trimethyl antimony(V) (TMeSb) were separated in less than 8min using anion exchange chromatography with a Hamilton PRP-X100 column as the stationary phase. Mobile phase A was 20mmolL -1 ethylenediaminetetraacetic acid (EDTA), 2mmolL -1 potassium hydrogen phthalate (KHP) in 1% v/v methanol (pH 5.5) and 20mmolL -1 EDTA, 2mmolL -1 KHP, 40mmolL -1 (NH 4 ) 2 CO 3 in 1% v/v methanol (pH 9.0) formed mobile phase B. Detection limits and relative standard deviations (RSD) were 0.012-0.032ngmL -1 and 2.2-2.8% respectively. This method was applied to bottled waters and fruit juices purchased in Kaohsiung, Taiwan. In water samples, Sb(V) was the major species where as in juices organometallic Sb species were also present. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Estimation of the quantification uncertainty from flow injection and liquid chromatography transient signals in inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Laborda, Francisco; Medrano, Jesus; Castillo, Juan R.

    2004-01-01

    The quality of the quantitative results obtained from transient signals in high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) and flow injection-inductively coupled plasma mass spectrometry (FI-ICPMS) was investigated under multielement conditions. Quantification methods were based on multiple-point calibration by simple and weighted linear regression, and double-point calibration (measurement of the baseline and one standard). An uncertainty model, which includes the main sources of uncertainty from FI-ICPMS and HPLC-ICPMS (signal measurement, sample flow rate and injection volume), was developed to estimate peak area uncertainties and statistical weights used in weighted linear regression. The behaviour of the ICPMS instrument was characterized in order to be considered in the model, concluding that the instrument works as a concentration detector when it is used to monitorize transient signals from flow injection or chromatographic separations. Proper quantification by the three calibration methods was achieved when compared to reference materials, although the double-point calibration allowed to obtain results of the same quality as the multiple-point calibration, shortening the calibration time. Relative expanded uncertainties ranged from 10-20% for concentrations around the LOQ to 5% for concentrations higher than 100 times the LOQ

  19. Elemental labelling combined with liquid chromatography inductively coupled plasma mass spectrometry for quantification of biomolecules: A review

    International Nuclear Information System (INIS)

    Kretschy, Daniela; Koellensperger, Gunda; Hann, Stephan

    2012-01-01

    Highlights: ► Survey of bio-analytical approaches utilizing biomolecule labelling. ► Detailed discussion of methodology and chemistry of elemental labelling. ► Biomedical and bio-analytical applications of elemental labelling. ► FI-ICP-MS and LC–ICP-MS for quantification of elemental labelled biomolecules. ► Review of selected applications. - Abstract: This article reviews novel quantification concepts where elemental labelling is combined with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS) or liquid chromatography inductively coupled plasma mass spectrometry (LC–ICP-MS), and employed for quantification of biomolecules such as proteins, peptides and related molecules in challenging sample matrices. In the first sections an overview on general aspects of biomolecule quantification, as well as of labelling will be presented emphasizing the potential, which lies in such methodological approaches. In this context, ICP-MS as detector provides high sensitivity, selectivity and robustness in biological samples and offers the capability for multiplexing and isotope dilution mass spectrometry (IDMS). Fundamental methodology of elemental labelling will be highlighted and analytical, as well as biomedical applications will be presented. A special focus will lie on established applications underlining benefits and bottlenecks of such approaches for the implementation in real life analysis. Key research made in this field will be summarized and a perspective for future developments including sophisticated and innovative applications will given.

  20. Elemental labelling combined with liquid chromatography inductively coupled plasma mass spectrometry for quantification of biomolecules: A review

    Science.gov (United States)

    Kretschy, Daniela; Koellensperger, Gunda; Hann, Stephan

    2012-01-01

    This article reviews novel quantification concepts where elemental labelling is combined with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS) or liquid chromatography inductively coupled plasma mass spectrometry (LC–ICP-MS), and employed for quantification of biomolecules such as proteins, peptides and related molecules in challenging sample matrices. In the first sections an overview on general aspects of biomolecule quantification, as well as of labelling will be presented emphasizing the potential, which lies in such methodological approaches. In this context, ICP-MS as detector provides high sensitivity, selectivity and robustness in biological samples and offers the capability for multiplexing and isotope dilution mass spectrometry (IDMS). Fundamental methodology of elemental labelling will be highlighted and analytical, as well as biomedical applications will be presented. A special focus will lie on established applications underlining benefits and bottlenecks of such approaches for the implementation in real life analysis. Key research made in this field will be summarized and a perspective for future developments including sophisticated and innovative applications will given. PMID:23062431

  1. Determination of Total Arsenic and Speciation in Apple Juice by Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry: An Experiment for the Analytical Chemistry Laboratory

    Science.gov (United States)

    He, Ping; Colon, Luis A.; Aga, Diana S.

    2016-01-01

    A two-part laboratory experiment was designed for upper-level analytical chemistry students to provide hands-on experience in the use of high performance liquid chromatography (HPLC) for separation and inductively coupled plasma mass spectrometry (ICP-MS) for detection. In the first part of the experiment, the students analyze total arsenic in…

  2. Comparative oxidation state specific analysis of arsenic species by high-performance liquid chromatography-inductively coupled-mass spectrometry and hydride generation-cryotrapping-atomic absorption spectrometry

    Science.gov (United States)

    The formation of methylarsonous acid (MAsIII) and dimethylarsinous acid (DMAsIII) in the course of inorganic arsenic (iAs) metabolism plays an important role in the adverse effects of chronic exposure to iAs. High-performance liquid chromatography-inductively coupled plasma-mass ...

  3. Separation of gold, palladium and platinum in chromite by anion exchange chromatography for inductively coupled plasma atomic emission spectrometric analysis

    International Nuclear Information System (INIS)

    Choi, Kwang Soon; Lee, Chang Heon; Park, Yeong Jae; Joe, Kih Soo; Kim, Won Ho

    2001-01-01

    A study has been carried out on the separation of gold, iridium, palladium, rhodium, ruthenium and platinum in chromite samples and their quantitative determination using inductively coupled plasma atomic emission spectrometry (ICP-AES). The dissolution condition of the minerals by fusion with sodium peroxide was optimized and chromatographic elution behavior of the rare metals was investigated by anion exchange chromatography. Spectral interference of chromium, a matrix of the minerals, was investigated on determination of gold. Chromium interfered on determination of gold at the concentration of 500 mg/L and higher. Gold plus trace amounts of iridium, palladium, rhodium and ruthenium, which must be preconcentrated before ICP-AES was separated by anion exchange chromatography after reducing Cr(VI) to Cr(III) by H 2 O 2 . AuCl - 4 retained on the resin column was selectively eluted with acetone- HNO 3 -H 2 O as an eluent. In addition, iridium, palladium, rhodium and ruthenium remaining on the resin column were eluted as a group with concentrated HCl. However, platinum was eluted with concentrated HNO 3 . The recovery yield of gold with acetone-HNO 3 -H 2 O was 100.7 ± 2.0 % , and the yields of palladium and platinum with concentrated HCl and HNO 3 were 96.1 ± 1.8% and 96.6 ± 1.3%, respectively. The contents of gold and platinum in a Mongolian chromite sample were 32.6 ± 2.2 μg/g and 1.6 ± 0.14 μg/g, respectively. Palladium was not detected

  4. High performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry for V and Ni quantification as tetrapyrroles

    Science.gov (United States)

    Duyck, Christiane Béatrice; Saint'Pierre, Tatiana Dillenburg; Miekeley, Norbert; da Fonseca, Teresa Cristina Oliveira; Szatmari, Peter

    2011-05-01

    A method was developed for the determination of V and Ni as tetrapyrroles by High Performance Liquid Chromatography hyphenated to Inductively Coupled Plasma Mass Spectrometry (HPLC-ICP-MS) using reversed phase and elution gradient. Chlorinated solvents and tetrahydrofuran were investigated as regard to separation time and ICP-MS detection efficiencies. The final elution gradient program started from pure methanol to a mixture of 20:80 (v/v) chloroform:methanol. External quantification of V and Ni with inorganic standards by flow injection ICP-MS, used online with HPLC, resulted in 95% of recoveries. The Limits of Detection for V during methanol elution and for Ni during the 20% chloroform gradient elution were evaluated by their minimum detectable concentrations, which were, respectively, 5 μg L - 1 and 8 μg L - 1 . The methodology was applied to polar and resin fractions separated from a Brazilian crude oil and a sediment extract from an oil-polluted area in the Guanabara Bay, Rio de Janeiro, Brazil. Vanadium as tetrapyrroles represented the totality of V content in the polar fraction, whereas Ni was in different polar forms in the resin and sediment extract.

  5. Fingerprinting of complex mixtures with the use of high performance liquid chromatography, inductively coupled plasma atomic emission spectroscopy and chemometrics

    International Nuclear Information System (INIS)

    Ni Yongnian; Peng Yunyan; Kokot, Serge

    2008-01-01

    The molecular and metal profile fingerprints were obtained from a complex substance, Atractylis chinensis DC-a traditional Chinese medicine (TCM), with the use of the high performance liquid chromatography (HPLC) and inductively coupled plasma atomic emission spectroscopy (ICP-AES) techniques. This substance was used in this work as an example of a complex biological material, which has found application as a TCM. Such TCM samples are traditionally processed by the Bran, Cut, Fried and Swill methods, and were collected from five provinces in China. The data matrices obtained from the two types of analysis produced two principal component biplots, which showed that the HPLC fingerprint data were discriminated on the basis of the methods for processing the raw TCM, while the metal analysis grouped according to the geographical origin. When the two data matrices were combined into a one two-way matrix, the resulting biplot showed a clear separation on the basis of the HPLC fingerprints. Importantly, within each different grouping the objects separated according to their geographical origin, and they ranked approximately in the same order in each group. This result suggested that by using such an approach, it is possible to derive improved characterisation of the complex TCM materials on the basis of the two kinds of analytical data. In addition, two supervised pattern recognition methods, K-nearest neighbors (KNNs) method, and linear discriminant analysis (LDA), were successfully applied to the individual data matrices-thus, supporting the PCA approach

  6. [Determination of iodine and its species in plant samples using ion chromatography-inductively coupled plasma mass spectrometry].

    Science.gov (United States)

    Lin, Li; Chen, Guang; Chen, Yuhong

    2011-07-01

    A method was established for the determination of iodine and its species in plant samples using ion chromatography-inductively coupled plasma mass spectrometry (IC-ICP/ MS). Alkaline extraction and IC-ICP/MS were applied as the sample pre-treatment method and the detection technique respectively, for iodate and iodide determination. Moreover, high-temperature pyrolysis absorption was adopted as the pre-treatment method for total iodine analysis, which finally converted all the iodine species into iodide and measured the iodide by IC-ICP/MS. The recoveries of iodine for alkaline extraction and high-temperature pyrolysis absorption were 89.6%-97.5% and 95.2%-111.2%, respectively. The results were satisfactory. The detection limit of iodine was 0.010 mg/kg. The iodine and its speciation contents in several kinds of plant samples such as seaweeds, kelp, cabbage, tea leaf and spinach were investigated. It was shown that the iodine in seaweeds mainly existed as organic iodine; while the ones in kelp, cabbage, tea leaf and spinach mainly existed as inorganic iodine.

  7. Functional speciation of metal-dissolved organic matter complexes by size exclusion chromatography coupled to inductively coupled plasma mass spectrometry and deconvolution analysis

    International Nuclear Information System (INIS)

    Laborda, Francisco; Ruiz-Begueria, Sergio; Bolea, Eduardo; Castillo, Juan R.

    2009-01-01

    High performance size exclusion chromatography coupled to inductively coupled plasma mass spectrometry (HP-SEC-ICP-MS), in combination with deconvolution analysis, has been used to obtain multielemental qualitative and quantitative information about the distributions of metal complexes with different forms of natural dissolved organic matter (DOM). High performance size exclusion chromatography coupled to inductively coupled plasma mass spectrometry chromatograms only provide continuous distributions of metals with respect to molecular masses, due to the high heterogeneity of dissolved organic matter, which consists of humic substances as well as biomolecules and other organic compounds. A functional speciation approach, based on the determination of the metals associated to different groups of homologous compounds, has been followed. Dissolved organic matter groups of homologous compounds are isolated from the aqueous samples under study and their high performance size exclusion chromatography coupled to inductively coupled plasma mass spectrometry elution profiles fitted to model Gaussian peaks, characterized by their respective retention times and peak widths. High performance size exclusion chromatography coupled to inductively coupled plasma mass spectrometry chromatograms of the samples are deconvoluted with respect to these model Gaussian peaks. This methodology has been applied to the characterization of metal-dissolved organic matter complexes in compost leachates. The most significant groups of homologous compounds involved in the complexation of metals in the compost leachates studied have been hydrophobic acids (humic and fulvic acids) and low molecular mass hydrophilic compounds. The environmental significance of these compounds is related to the higher biodegradability of the low molecular mass hydrophilic compounds and the lower mobility of humic acids. In general, the hydrophilic compounds accounted for the complexation of around 50% of the leached

  8. [Determination of five arsenic species in rice by liquid chromatography-inductively coupled plasma-mass spectrometry].

    Science.gov (United States)

    Gong, Jiadi; Cao, Xiaolin; Cao, Zhaoyun; Bian, Yingfang; Yu, Shasha; Chen, Mingxue

    2014-07-01

    A method was developed for the simultaneous determination of arsenic acid [As (V)], arsenious acid [As (III)], arsenobetaine (AsB), monomethylarsonic acid (MMA) and dimethylarsinic acid (DMA) in rice by liquid chromatography-inductively coupled plasma-mass spectrometry (LC-ICP-MS). The extraction reagent was 0.3 mol/L nitric acid with heat-assistant condition for 1.5 h at 95 degrees C. Then, the five arsenic species were separated by an anion exchange column (Dionex IonPac AS19, 250 mm x 4 mm) and detected by ICP-MS. Four kinds of extracted solutions were compared through the extraction efficiency. The concentration of nitric acid, the temperature and the extraction time were optimized. The recoveries of the five arsenic species spiked in rice at two levels ranged from 89.6% to 99.5% with the relative standard deviations (RSDs, n = 5) of 0.6% - 3.6%. The measured values of the arsenic species in standard rice materials were consistent with their standard values. The linear ranges were 0.05 - 200 microg/L for AsB and DMA, 0.10-400 microg/L for As (III) and MMA, 0.15-600 microg/L for As (V). The limits of detection for the five arsenic species were 0.15-0.45 microg/kg. The results showed that the method is much more precise for the risk assessment of the rice. This method is simple, accurate and durable for the determination of arsenic species in rice.

  9. Evaluation of liquid chromatography inductively coupled plasma mass spectrometry for arsenic speciation in water from industrial treatment of shale

    Energy Technology Data Exchange (ETDEWEB)

    Duarte, Fabio Andrei; Fagundes Pereira, Juliana Severo; Mesko, Marcia Foster; Goldschmidt, Fabiane; Moraes Flores, Erico Marlon de; Dressler, Valderi Luiz, E-mail: valdres@quimica.ufsm.br

    2007-09-15

    This work describes an arsenic speciation analysis in aqueous effluent from a shale industrial plant using liquid chromatography coupled to inductively coupled plasma mass spectrometry (LC-ICP-MS). Arsenic species have been separated through an anion-exchange column and several parameters investigated, such as retention time, pH, flow rate and concentration of the mobile phase (ammonium carbonate), chloride interference and column conditioning time. The best conditions have been found by fixing the pH of the mobile phase at 8.7. Keeping the mobile phase flow rate at 1.5 ml min{sup -1}, arsenic species were separated by varying the concentration of the mobile phase and the time of elution, as follow: 1.5 mmol l{sup -1} for 10 min, 12 mmol l{sup -1} for 10 min and 20 mmol l{sup -1} for 10 min, respectively. Up to 13 As species present in the samples were separated under these conditions and the following species could be identified and quantified: arsenite [As(III)], dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and arsenate [As(V)]. The limits of detection of the LC-ICP-MS method were 0.02, 0.06, 0.04 and 0.10 {mu}g l{sup -1} of As(III), DMA, MMA, and As(V), respectively. The concentration of these species in the samples were from 3.7 to 6.4 {mu}g l{sup -1}, 6.9 to 13.2 {mu}g l{sup -1}, 100 to 142 {mu}g l{sup -1} and 808 to 1363 {mu}g l{sup -1} for As(III), DMA, MMA and As(V), respectively. The accuracy, evaluated by recovery tests, varied from 94 to 105% and the precision, evaluated by the relative standard deviation was typically lower than 10%.

  10. Determination of technetium-99 in soil samples by high performance liquid chromatography coupled to inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Muto, Toshio; Shimokawa, Toshinari

    1997-01-01

    A new powerful analytical technique viz. high performance liquid chromatography(HPLC) coupled to inductively coupled plasma mass spectrometry(HPLC/ICP-MS) has been applied to the determination of technetium-99( 99 Tc) in soils as a typical environmental sample. Technetium was enriched in a solution from incinerated soil samples by leaching in HNO 3 and passed through 'TEVA resin' column. The solution was injected into HPLC/ICP-MS system to eliminate the interfering elements (i.e. Ru and Mo) and to determine the 99 Tc concentration at the same time. The concentrations of 99 Tc in the incinerated soils were found to be 0.49Bq/kg(0.77ng/kg)-1.4Bq/kg(2.2ng/kg) with the determination limit of 0.02Bq/kg(0.03ng/kg(0.03ppt)). The results indicate the following findings; 1) the determination of 99 Tc by ICP-MS after strict elimination of the interfering elements by HPLC brings about the improvement in their reliability; 2) the detection limits identified are much lower compared with those by conventional ICP-MS methods because of the concentration of 99 Tc to smaller volume, which is due to only 100μl of samples could be measured by HPLC/ICP-MS system; 3) sample preparation could be simplified because of strict elimination of the interfering elements by HPLC. This research showed that HPLC/ICP-MS system is very effective to determine 99 Tc in environmental samples. (author)

  11. Separation of silver ions and starch modified silver nanoparticles using high performance liquid chromatography with ultraviolet and inductively coupled mass spectrometric detection

    International Nuclear Information System (INIS)

    Hanley, Traci A.; Saadawi, Ryan; Zhang, Peng; Caruso, Joseph A.; Landero-Figueroa, Julio

    2014-01-01

    The production of commercially available products marketed to contain silver nanoparticles is rapidly increasing. Species-specific toxicity is a phenomenon associated with many elements, including silver, making it imperative to develop a method to identify and quantify the various forms of silver (namely, silver ions vs. silver nanoparticles) possibly present in these products. In this study a method was developed using high performance liquid chromatography (HPLC) with ultraviolet (UV–VIS) and inductively coupled mass spectrometric (ICP-MS) detection to separate starch stabilized silver nanoparticles (AgNPs) and silver ions (Ag + ) by cation exchange chromatography with 0.5 M nitric acid mobile phase. The silver nanoparticles and ions were baseline resolved with an ICP-MS response linear over four orders of magnitude, 0.04 mg kg −1 detection limit, and 90% chromatographic recovery for silver solutions containing ions and starch stabilized silver nanoparticles smaller than 100 nm

  12. Separation of silver ions and starch modified silver nanoparticles using high performance liquid chromatography with ultraviolet and inductively coupled mass spectrometric detection

    Energy Technology Data Exchange (ETDEWEB)

    Hanley, Traci A.; Saadawi, Ryan; Zhang, Peng; Caruso, Joseph A., E-mail: joseph.caruso@uc.edu; Landero-Figueroa, Julio

    2014-10-01

    The production of commercially available products marketed to contain silver nanoparticles is rapidly increasing. Species-specific toxicity is a phenomenon associated with many elements, including silver, making it imperative to develop a method to identify and quantify the various forms of silver (namely, silver ions vs. silver nanoparticles) possibly present in these products. In this study a method was developed using high performance liquid chromatography (HPLC) with ultraviolet (UV–VIS) and inductively coupled mass spectrometric (ICP-MS) detection to separate starch stabilized silver nanoparticles (AgNPs) and silver ions (Ag{sup +}) by cation exchange chromatography with 0.5 M nitric acid mobile phase. The silver nanoparticles and ions were baseline resolved with an ICP-MS response linear over four orders of magnitude, 0.04 mg kg{sup −1} detection limit, and 90% chromatographic recovery for silver solutions containing ions and starch stabilized silver nanoparticles smaller than 100 nm.

  13. Induction and removal of DNA interstrand cross-links in V-79 Chinese hamster cells measured by hydroxylapatite chromatography after treatments with bifunctional furocoumarins

    International Nuclear Information System (INIS)

    Dardalhon, M.; Averbeck, D.

    1988-01-01

    DNA interstrand crosslinks (CL) photoinduced by bifunctional furocoumarins in V-79 Chinese hamster cells were measured by alkaline denaturation and hydroxylapatite chromatography. Treatments with 5-methoxypsoralen (5-MOP), 8-methoxypsoralen (8-MOP) and 4,5',8-trimethylpsoralen (4,5',8-TMP) and 365 nm irradiation (UVA) confer a dose-dependent linear increase in the amount of double-stranded DNA indicating the induction of CL. Determination in alkaline sucrose gradients of the molecular weight of the DNA and estimation of drug-induced strand breakage allowed quantification of the CL induced. 5-MOP was found to be slightly more effective than 8-MOP whereas 4,5',8-TMP was 9 times more effective for the induction of CL. The fate of CL during post-treatment incubation was also followed. Cells in exponential growth phase were found to be efficient in the removal of CL. (Author)

  14. Gas chromatography--inductively coupled plasma--time-of-flight mass spectrometry for the speciation analysis of organolead compounds in environmental water samples.

    Science.gov (United States)

    Heisterkamp, M; Adams, F C

    2001-07-01

    The application of inductively coupled plasma--time-of-flight mass spectrometry for the speciation analysis of organolead compounds in environmental waters is described. Construction of the transfer line was achieved by means of a relatively simple and rapid coupling procedure. Derivatization of the ionic lead species was achieved by in-situ propylation with sodium tetrapropylborate; simultaneous extraction of the derivatized compounds in hexane was followed by separation and detection by capillary gas chromatography hyphenated to inductively coupled plasma-time-of-flight mass spectrometry. Detection limits for the different organolead species ranged from 10 to 15 fg (as Pb), corresponding to procedural detection limits between 50 and 75 ng L(-1), on the basis of a 50 mL snow sample, extraction with 200 microL hexane, and subsequent injection of 1 microL of the organic extract on to the column. The accuracy of the system was confirmed by additional analysis of the water samples by capillary gas chromatography coupled with microwave-induced plasma-atomic-emission spectrometry and the analysis of a standard reference material CRM 605 (road dust) with a certified content of trimethyllead.

  15. Hyphenation of ultra performance liquid chromatography (UPLC) with inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of bromine containing preservatives

    DEFF Research Database (Denmark)

    Bendahl, Lars; Hansen, Steen Honoré; Gammelgaard, Bente

    2006-01-01

    Ultra performance liquid chromatography (UPLC) was coupled to inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of three bromine-containing preservatives, monitoring the 79Br and 81Br isotopes simultaneously. Due to the efficiency of the 1.7 microm column packing material, t...... analysis of bromine-containing preservatives in commercially available cosmetic products.......Ultra performance liquid chromatography (UPLC) was coupled to inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of three bromine-containing preservatives, monitoring the 79Br and 81Br isotopes simultaneously. Due to the efficiency of the 1.7 microm column packing material...... at an intermediate and at a high linear velocity. The precision was better than 2.2% R.S.D. and regression analysis showed that a linear response was achieved at both flow rates (R2 > 0.9993, n = 36). The analysis time was less than 4.5 min at a flow rate of 50 microL min(-1) and limits of detection...

  16. Method optimization and quality assurance in speciation analysis using high performance liquid chromatography with detection by inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt

    1998-01-01

    Achievement of optimum selectivity, sensitivity and robustness in speciation analysis using high performance liquid chromatography (HPLC) with inductively coupled mass spectrometry (ICP-MS) detection requires that each instrumental component is selected and optimized with a view to the ideal....... The optimized anion and cation exchange HPLC-ICP-MS systems were used for arsenic speciation in contaminated ground water and in an in-house shrimp reference sample. For the purpose of verification, HPLC coupled with tandem mass spectrometry with electrospray ionization was additionally used for arsenic...... a mass balance of the analytes in each fraction of the extraction procedure, by recovery of spikes and by employing and comparing independent techniques. The urgent need for reference materials certified for elemental species is stressed....

  17. Rapid Determination of Plutonium Isotopes in Environmental Samples Using Sequential Injection Extraction Chromatography and Detection by Inductively Coupled Plasma Mass Spectrometry

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2009-01-01

    This article presents an automated method for the rapid determination of 239Pu and 240Pu in various environmental samples. The analytical method involves the in-line separation of Pu isotopes using extraction chromatography (TEVA) implemented in a sequential injection (SI) network followed...... by detection of isolated analytes with inductively coupled plasma mass spectrometry (ICP-MS). The method has been devised for the determination of Pu isotopes at environmentally relevant concentrations, whereby it has been successfully applied to the analyses of large volumes/amounts of samples, for example......, 100−200 g of soil and sediment, 20 g of seaweed, and 200 L of seawater following analyte preconcentration. The investigation of the separation capability of the assembled SI system revealed that up to 200 g of soil or sediment can be treated using a column containing about 0.70 g of TEVA resin...

  18. Speciation of eight arsenic compounds in human urine by high performance liquid chromatography with inductively coupled plasma mass spectrometric detection using antimonate for internal chromatographic standardization

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt; Pritzl, G.; Hansen, S. H.

    1993-01-01

    Four anionic and four cationic arsenic compounds in urine were separated by anion- and cation-exchange high-performance liquid chromatography and detected by inductively coupled plasma mass spectrometry (ICP-MS) at m/z 75. The species were the anions arsenite, arsenate, monomethylarsonate...... and dimethylarsinate and the cations arsenobetaine, trimethylarsine oxide, arsenocholine and the tetramethylarsonium ion. Hexahydroxyantimonate(III) was co-chromatographed with the arsenic anions but detected at m/z 121 and used as an internal standard for their qualitative analysis. Arsenite was prone to oxidation....... The argon chloride interference at m/z 75 was eliminated by chromatographic separation of the chloride present in the sample from the arsenic analytes. The ClO+ ion detected at m/z 51 and 53 was used to monitor the retention time of chloride in the anion-exchange system. The chloride eluted about 100 s...

  19. A rapid monitoring method for inorganic arsenic in rice flour using reversed phase-high performance liquid chromatography-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Narukawa, Tomohiro; Chiba, Koichi; Sinaviwat, Savarin; Feldmann, Jörg

    2017-01-06

    A new rapid monitoring method by means of high performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) following the heat-assisted extraction was developed for measurement of total inorganic arsenic species in rice flour. As(III) and As(V) eluted at the same retention time and completely separated from organoarsenic species by an isocratic elution program on a reversed phase column. Therefore, neither ambiguous oxidation of arsenite to arsenate nor the integration of two peaks were necessary to determine directly the target analyte inorganic arsenic. Rapid injection allowed measuring 3 replicates within 6min and this combined with a quantitative extraction of all arsenic species from rice flour by a 15min HNO 3 -H 2 O 2 extraction makes this the fastest laboratory based method for inorganic arsenic in rice flour. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Ultra-Sensitive Elemental Analysis Using Plasmas 5.Speciation of Arsenic Compounds in Biological Samples by High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry System

    Science.gov (United States)

    Kaise, Toshikazu

    Arsenic originating from the lithosphere is widely distributed in the environment. Many arsenicals in the environment are in organic and methylated species. These arsenic compounds in drinking water or food products of marine origin are absorbed in human digestive tracts, metabolized in the human body, and excreted viatheurine. Because arsenic shows varying biological a spects depending on its chemical species, the biological characteristics of arsenic must be determined. It is thought that some metabolic pathways for arsenic and some arsenic circulation exist in aqueous ecosystems. In this paper, the current status of the speciation analysis of arsenic by HPLC/ICP-MS (High Performance Liquid Chromatography-Inductively Coupled Plasma Mass spectrometry) in environmental and biological samples is summarized using recent data.

  1. Method for the quantification of vanadyl porphyrins in fractions of crude oils by High Performance Liquid Chromatography-Flow Injection-Inductively Coupled Plasma Mass Spectrometry

    Science.gov (United States)

    Wandekoken, Flávia G.; Duyck, Christiane B.; Fonseca, Teresa C. O.; Saint'Pierre, Tatiana D.

    2016-05-01

    High performance liquid chromatography hyphenated by flow injection to inductively coupled plasma mass spectrometry (HPLC-FI-ICP-MS) was used to investigate V linked to porphyrins present in fractions of crude oil. First, the crude oil sample was submitted to fractionation by preparative liquid chromatography with UV detection, at the porphyrin Soret band wavelength (400 nm). The obtained porphyrin fractions were then separated in a 250 mm single column, in the HPLC, and eluted with different mobile phases (methanol or methanol:toluene (80:20; v:v)). The quantification of V-porphyrins in the fractions eluted from HPLC was carried out by online measuring the 51V isotope in the ICP-MS, against vanadyl octaethylporphine standard solutions (VO-OEP), prepared in the same solvent as the mobile phase, and injected post-column directly into the plasma. A 20 μg L- 1 Ge in methanol was used as internal standard for minimizing non-spectral interference, such as short-term variations due to injection. The mathematical treatment of the signal based on Fast Fourier Transform smoothing algorithm was employed to improve the precision. The concentrations of V as V-porphyrins were between 2.7 and 11 mg kg- 1 in the fractions, which were close to the total concentration of V in the porphyrin fractions of the studied crude oil.

  2. Speciation of arsenic in marine food (Anemonia sulcata) by liquid chromatography coupled to inductively coupled plasma mass spectrometry and organic mass spectrometry.

    Science.gov (United States)

    Contreras-Acuña, M; García-Barrera, T; García-Sevillano, M A; Gómez-Ariza, J L

    2013-03-22

    Arsenic species have been investigated in Anemonia sulcata, which is frequently consumed food staple in Spain battered in wheat flour and fried with olive oil. Speciation in tissue extracts was carried out by anion/cation exchange chromatography with inductively coupled plasma mass spectrometry (HPLC-(AEC/CEC)-ICP-MS). Three methods for the extraction of arsenic species were investigated (ultrasonic bath, ultrasonic probe and focused microwave) and the optimal one was applied. Arsenic speciation was carried out in raw and cooked anemone and the dominant species are dimethylarsinic acid (DMA(V)) followed by arsenobetaine (AB), As(V), monomethylarsonic acid (MA(V)), tetramethylarsonium ion (TETRA) and trimethylarsine oxide (TMAO). In addition, arsenocholine (AsC), glyceryl phosphorylarsenocholine (GPAsC) and dimethylarsinothioic acid (DMAS) were identified by liquid chromatography coupled to triple quadrupole mass spectrometry (HPLC-MS). These results are interesting since GPAsC has been previously reported in marine organisms after experimental exposure to AsC, but not in natural samples. In addition, this paper reports for the first time the identification of DMAS in marine food. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Investigation of mercury-containing proteins by enriched stable isotopic tracer and size-exclusion chromatography hyphenated to inductively coupled plasma-isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Shi Junwen; Feng Weiyue; Wang Meng; Zhang Fang; Li Bai; Wang Bing; Zhu Motao; Chai Zhifang

    2007-01-01

    In order to investigate trace mercury-containing proteins in maternal rat and their offspring, a method of enriched stable isotopic tracer ( 196 Hg and 198 Hg) combined with size-exclusion chromatography (SEC) coupled to inductively coupled plasma-isotope dilution mass spectrometry (ICP-IDMS) was developed. Prior to the analysis, 196 Hg- and 198 Hg-enriched methylmercury was administrated to the pregnant rats. Then the mercury-containing proteins in serum and brain cytosol of the dam and pup rats were separated by size-exclusion columns and the mercury was detected by ICP-MS. The ICP-MS spectrogram of the tracing samples showed significantly elevated 196 Hg and 198 Hg isotopic signals compared with the natural ones, indicating that the detection sensitivity could be increased by the tracer method. The contents of mercury in chromatographic fractions of the dam and pup rat brain cytosol were quantitatively estimated by post-column reverse ID-ICP-MS. The quantitative speciation differences of mercury in brain cytosol between the dam and pup rats were observed, indicating that such studies could be useful for toxicological estimation. Additionally, the isotopic ratio measurement of 198 Hg/ 202 Hg in the tracing samples could be used to identify the artifact mercury species caused in the analytical procedure. The study demonstrates that the tracer method combined with high-performance liquid chromatography (HPLC)-ICP-IDMS could provide reliably qualitative and quantitative information on mercury-containing proteins in organisms

  4. Environmental application of elemental speciation analysis based on liquid or gas chromatography hyphenated to inductively coupled plasma mass spectrometry-A review

    International Nuclear Information System (INIS)

    Popp, Maximilian; Hann, Stephan; Koellensperger, Gunda

    2010-01-01

    In recent years the number of environmental applications of elemental speciation analysis using inductively coupled plasma mass spectrometry (ICP-MS) as detector has increased significantly. The analytical characteristics, such as extremely low detection limits (LOD) for almost all elements, the wide linear range, the possibility for multi-elemental analysis and the possibility to apply isotope dilution mass spectrometry (IDMS) make ICP-MS an attractive tool for elemental speciation analysis. Two methodological approaches, i.e. the combination of ICP-MS with high performance liquid chromatography (HPLC) and gas chromatography (GC), dominate the field. Besides the investigation of metals and metalloids and their species (e.g. Sn, Hg, As), representing 'classic' elements in environmental science, more recently other elements (e.g. P, S, Br, I) amenable to ICP-MS determination were addressed. In addition, the introduction of isotope dilution analysis and the development of isotopically labeled species-specific standards have contributed to the success of ICP-MS in the field. The aim of this review is to summarize these developments and to highlight recent trends in the environmental application of ICP-MS coupled to GC and HPLC.

  5. Determination of 20 trace elements and arsenic species for a realgar-containing traditional Chinese medicine Niuhuang Jiedu tablets by direct inductively coupled plasma-mass spectrometry and high performance liquid chromatography-inductively coupled plasma-mass spectrometry.

    Science.gov (United States)

    Jin, Pengfei; Liang, Xiaoli; Xia, Lufeng; Jahouh, Farid; Wang, Rong; Kuang, Yongmei; Hu, Xin

    2016-01-01

    Niuhuang Jiedu tablet (NHJDT) is a realgar-containing traditional Chinese medicine. A direct inductively coupled plasma-mass spectrometry (ICP-MS) method for the simultaneous determination of 20 trace elements (Mg, K, Ca, Na, Fe, As, Zn, Sr, Ba, Cu, Mn, Ni, Pb, V, Cr, Se, Co, Mo, Cd, Hg) in NHJDT, as well as in water, gastric fluid and intestinal fluid was established. Meanwhile, a high performance liquid chromatography-inductively coupled plasma-mass spectrometry (HPLC-ICP-MS) method was developed for the determination of arsenite (As(III)), arsenate (As(V)), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA) and for the identification of arsenobetaine (AsB) and arsenocholine (AsC) in these extracts. Both methods were fully validated in the respect of linearity, sensitivity, precision, stability and accuracy. The reliability of the ICP-MS method was further evaluated using a certified standard reference material prepared from dried tomato leaves (NIST, SRM 1572a). The analysis showed that some manufacturers formulated lower amount of realgar than required in the Chinese Pharmacopoeia (ChP) in their preparations. In addition, almost same extraction profiles for total As and inorganic As were found in water and in gastrointestinal fluids, while higher extraction rates for other 19 elements were observed in gastrointestinal fluids. Our findings show that the toxicities of Hg, Cu, Cd and Pb in NHJDP are low, while the real As toxicity in NHJDT should be deeply investigated. Copyright © 2015 Elsevier GmbH. All rights reserved.

  6. Application of high performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) for determination of chromium compounds in the air at the workplace.

    Science.gov (United States)

    Stanislawska, Magdalena; Janasik, Beata; Wasowicz, Wojciech

    2013-12-15

    The toxicity and bioavailability of chromium species are highly dependable on the form or species, therefore determination of total chromium is insufficient for a complete toxicological evaluation and risk assessment. An analytical method for determination of soluble and insoluble Cr (III) and Cr (VI) compounds in welding fume at workplace air has been developed. The total chromium (Cr) was determined by using quadruple inductively coupled plasma mass spectrometry (ICP-MS) equipped with a dynamic reaction cell (DRC(®)). Soluble trivalent and hexavalent chromium compounds were determined by high performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS). A high-speed, reversed-phase CR C8 column (PerkinElmer, Inc., Shelton, CT, USA) was used for the speciation of soluble Cr (III) and soluble Cr (VI). The separation was accomplished by interaction of the chromium species with the different components of the mobile phase. Cr (III) formed a complex with EDTA, i.e. retained on the column, while Cr (VI) existed in the solutions as dichromate. Alkaline extraction (2% KOH and 3% Na2CO3) and anion exchange column (PRP-X100, PEEK, Hamilton) were used for the separation of the total Cr (VI). The results of the determination of Cr (VI) were confirmed by the analysis of the certified reference material BCR CRM 545 (Cr (VI) in welding dust). The results obtained for the certified material (40.2±0.6 g kg(-1)) and the values recorded in the examined samples (40.7±0.6 g kg(-1)) were highly consistent. This analytical method was applied for the determination of chromium in the samples in the workplace air collected onto glass (Whatman, Ø 37 mm) and membrane filters (Sartorius, 0.8 μm, Ø 37 mm). High performance liquid chromatography with inductively coupled plasma mass spectrometry is a remarkably powerful and versatile technique for determination of chromium species in welding fume at workplace air. Crown Copyright © 2013 Published by

  7. Speciation of Selenium in Selenium-Enriched Sunflower Oil by High-Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry/Electrospray-Orbitrap Tandem Mass Spectrometry.

    Science.gov (United States)

    Bierla, Katarzyna; Flis-Borsuk, Anna; Suchocki, Piotr; Szpunar, Joanna; Lobinski, Ryszard

    2016-06-22

    The reaction of sunflower oil with selenite produces a complex mixture of selenitriglycerides with antioxidant and anticancer properties. To obtain insight into the identity and characteristics of the species formed, an analytical approach based on the combination of high-performance liquid chromatography (HPLC) with (78)Se-specific selenium detection by inductively coupled plasma mass spectrometry (ICP MS) and high-resolution (100 000), high mass accuracy (HPLC-ICP MS for the separation of a complex mixture of selenospecies and a mathematical correction of the background signal was developed. The identical chromatographic conditions served for the sample introduction into electrospray MS. Two types of samples were analyzed: sunflower oil dissolved in isopropanol and methanol extract of the oil containing 65% selenium. HPLC-ICP MS showed 14 peaks, 11 of which could also be detected in the methanol extract. Isotopic patterns corresponding to molecules with one or two selenium atoms could be attributed by Orbitrap MS at the retention times corresponding to the HPLC-ICP MS peak apexes. Structural data for these species were acquired by MS(2) and MS(3) fragmentation of protonated or sodiated ions using high-energy collisional dissociation (HCD). A total of 11 selenium-containing triglycerol derivatives resulting from the oxidation of one or two double bonds of linoleic acid and analogous derivatives of glycerol-mixed linoleate(s)/oleinate(s) have been identified for the first time. The presence of these species was confirmed by the targeted analysis in the total oil isopropanol solution. Their identification corroborated the predicted elution order in reversed-phase chromatography: LLL (glycerol trilinoleate), LLO (glycerol dilinoleate-oleinate), LOO (glycerol linoleate-dioleinate), OOO (glycerol trioleinate), of which the extrapolation allowed for the prediction of the identity [glycerol dioleinate-stearate (OOS) and glycerol oleinate-distearate (OSS)] of the

  8. Investigation of mercury-containing proteins by enriched stable isotopic tracer and size-exclusion chromatography hyphenated to inductively coupled plasma-isotope dilution mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Shi Junwen [Laboratory for Bio-Environmental Health Sciences of Nanoscale Materials and Key Laboratory of Nuclear Analytical Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)]|[Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Feng Weiyue [Laboratory for Bio-Environmental Health Sciences of Nanoscale Materials and Key Laboratory of Nuclear Analytical Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)]. E-mail: fengwy@mail.ihep.ac.cn; Wang Meng [Laboratory for Bio-Environmental Health Sciences of Nanoscale Materials and Key Laboratory of Nuclear Analytical Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)]|[Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Zhang Fang [Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Li Bai [Laboratory for Bio-Environmental Health Sciences of Nanoscale Materials and Key Laboratory of Nuclear Analytical Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Wang Bing; Zhu Motao [Laboratory for Bio-Environmental Health Sciences of Nanoscale Materials and Key Laboratory of Nuclear Analytical Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)]|[Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Chai Zhifang [Laboratory for Bio-Environmental Health Sciences of Nanoscale Materials and Key Laboratory of Nuclear Analytical Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)]|[Institute of Nuclear Technology, Shenzhen University, Shenzhen 518060 (China)]|[Institute of Nanochemistry and Nanosafety, Shanghai University, Shanghai (China)

    2007-01-30

    In order to investigate trace mercury-containing proteins in maternal rat and their offspring, a method of enriched stable isotopic tracer ({sup 196}Hg and {sup 198}Hg) combined with size-exclusion chromatography (SEC) coupled to inductively coupled plasma-isotope dilution mass spectrometry (ICP-IDMS) was developed. Prior to the analysis, {sup 196}Hg- and {sup 198}Hg-enriched methylmercury was administrated to the pregnant rats. Then the mercury-containing proteins in serum and brain cytosol of the dam and pup rats were separated by size-exclusion columns and the mercury was detected by ICP-MS. The ICP-MS spectrogram of the tracing samples showed significantly elevated {sup 196}Hg and {sup 198}Hg isotopic signals compared with the natural ones, indicating that the detection sensitivity could be increased by the tracer method. The contents of mercury in chromatographic fractions of the dam and pup rat brain cytosol were quantitatively estimated by post-column reverse ID-ICP-MS. The quantitative speciation differences of mercury in brain cytosol between the dam and pup rats were observed, indicating that such studies could be useful for toxicological estimation. Additionally, the isotopic ratio measurement of {sup 198}Hg/{sup 202}Hg in the tracing samples could be used to identify the artifact mercury species caused in the analytical procedure. The study demonstrates that the tracer method combined with high-performance liquid chromatography (HPLC)-ICP-IDMS could provide reliably qualitative and quantitative information on mercury-containing proteins in organisms.

  9. Precise determination of dissolved silica in seawater by ion-exclusion chromatography isotope dilution inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Nonose, Naoko; Cheong, Chikako; Ishizawa, Yukari; Miura, Tsutomu; Hioki, Akiharu

    2014-08-20

    Ion exclusion chromatograph (IEC) isotope dilution (ID) inductively coupled plasma mass spectrometry (ICP-MS) (IEC-ID-ICP-MS) was developed for measurement of dissolved silica in seawater, which was applied to production of certified reference materials (CRMs) of three concentration levels of nutrients (high, medium and low levels). IEC-ICP-MS has been employed to separate dissolved silica from seawater matrix. In the present study, in order to solve substantial problems due to spectral interference in ICP-MS and to improve the accuracy of IEC-ICP-MS beyond standard addition or conventional calibration methods, ID method was coupled with ICP-sector field mass spectrometry (operated under medium resolution,i.e., m/Δm=4000). In addition, effects of various operating parameters in ICP-MS on a silicon background level were also investigated to obtain lower background equivalent concentration (BEC). As a result, 3 ng g(-1) of the BEC and 0.5 % of relative standard uncertainties were achieved in the analyses of dissolved silica in seawater samples at concentration levels from 4.0 mg kg (-1) to 0.8 mg kg(-1) as silicon. The developed method was successfully validated by analyses of an artificial seawater containing a known amount of silicate and the seawater certified reference material MOOS-2 produced by the National Research Council Canada. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Speciation of the bio-available iodine and bromine forms in edible seaweed by high performance liquid chromatography hyphenated with inductively coupled plasma-mass spectrometry

    International Nuclear Information System (INIS)

    Romarís-Hortas, Vanessa; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Jorge; Moreda-Piñeiro, Antonio

    2012-01-01

    Highlights: ► Bioavailable iodine and bromine speciation in edible seaweed were developed. ► In vitro dialyzability was used to assess the bioavailable fractions. ► AEC hyphenated with inductively coupled plasma-mass spectrometry was used. ► Iodide, MIT, DIT, bromide and bromate were found in dialyzates from edible seaweed. ► Positive correlation between bioavailability and protein contents was found. - Abstract: A bioavailability study based on an in vitro dialyzability approach has been applied to assess the bio-available fractions of iodine and bromine species from edible seaweed. Iodide, iodate, 3-iodo-tyrosine (MIT), 3,5-diiodo-tyrosine (DIT), bromide and bromate were separated by anion exchange chromatography under a gradient elution mode (175 mM ammonium nitrate plus 15% (v/v) methanol, pH 3.8, as a mobile phase, and flow rates within the 0.5–1.5 mL min −1 range). Inductively coupled plasma-mass spectrometry (ICP-MS) was used as a selective detector for iodine ( 127 I) and bromine ( 79 Br). Low dialyzability ratios (within the 2.0–18% range) were found for iodine species; whereas, moderate dialyzability percentages (from 9.0 to 40%) were obtained for bromine species. Iodide and bromide were the major species found in the dialyzates from seaweed, although MIT and bromate were also found in the dialyzates from most of the seaweed samples analysed. However, DIT was only found in dialyzates from Wakame, Kombu, and NIES 09 (Sargasso) certified reference material; whereas, iodate was not found in any dialyzate. Iodine dialyzability was found to be dependent on the protein content (negative correlation), and on the carbohydrate and dietary fibre levels (positive correlation). However, bromine dialyzability was only dependent on the protein amount in seaweed (negative correlation).

  11. [Simultaneous determination of 7 arsenic species in chicken muscle and chicken liver with high performance liquid chromatography-inductively coupled plasma mass spectrometry].

    Science.gov (United States)

    Yang, Lijun; Hu, Qiaoru; Guo, Wei; Liu, Yumin; Song, Xiaohua; Zhang, Pengcheng

    2011-05-01

    A method for the simultaneous determination of 7 arsenic species was developed with high performance liquid chromatography and inductively coupled plasma mass spectrometry (HPLC-ICP-MS). The sample was extracted with artificial gastric juice. The HPLC separation was performed on an anion analytical column utilizing a gradient elution program of ammonium carbonate and water as the mobile phase. Identification and quantification were achieved by ICP-MS. Good linearities of 7 arsenic species were observed in the range from 1 microg/kg to 50 microg/kg with the correlation coefficients greater than 0.999. The average recoveries of 7 arsenic species spiked at the three levels of 1, 2 and 10 microg/kg ranged from 84.3% to 106.6% with the relative standard deviations of 1.4%-4.2%. The quantification limits of 7 arsenic species were 1 microg/kg. The method was proved to be good reproducibility, high sensitivity and simple preprocessing. This method is suitable for the simultaneous determination of 7 arsenic species in chicken muscle and chicken liver.

  12. Fast Determination of Toxic Arsenic Species in Food Samples Using Narrow-bore High-Performance Liquid-Chromatography Inductively Coupled Plasma Mass Spectrometry.

    Science.gov (United States)

    Terol, Amanda; Marcinkowska, Monika; Ardini, Francisco; Grotti, Marco

    2016-01-01

    A new method for the speciation analysis of arsenic in food using narrow-bore high-performance liquid-chromatography inductively coupled plasma mass spectrometry (HPLC-ICP-MS) has been developed. Fast separation of arsenite, arsenate, monomethylarsonic acid and dimethylarsinic acid was carried out in 7 min using an anion-exchange narrow-bore Nucleosil 100 SB column and 12 mM ammonium dihydrogen phosphate of pH 5.2 as the mobile phase, at a flow rate of 0.3 mL min(-1). A PFA-ST micronebulizer jointed to a cyclonic spray chamber was used for HPLC-ICP-MS coupling. Compared with standard-bore HPLC-ICP-MS, the new method has provided higher sensitivity, reduced mobile-phase consumption, a lower matrix plasma load and a shorter analysis time. The achieved instrumental limits of detection were in the 0.3 - 0.4 ng As mL(-1) range, and the precision was better than 3%. The arsenic compounds were efficiently (>80%) extracted from various food samples using a 1:5 methanol/water solution, with additional ultrasonic treatment for rice products. The applicability of this method was demonstrated by the analysis of several samples, such as seafood (fish, mussels, shrimps, edible algae) and rice-based products (Jasmine and Arborio rice, spaghetti, flour, crackers), including three certified reference materials.

  13. Simultaneous determination of arsenic and mercury species in rice by ion-pairing reversed phase chromatography with inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Fang, Yong; Pan, Yushi; Li, Peng; Xue, Mei; Pei, Fei; Yang, Wenjian; Ma, Ning; Hu, Qiuhui

    2016-12-15

    An analytical method using reversed phase chromatography-inductively coupled plasma mass spectrometry for arsenic and mercury speciation analysis was described. The effect of ion-pairing reagent on simultaneous separation of four arsenic (arsenite, arsenate, monomethlyarsonate and dimethylarsinate) and three mercury species (inorganic mercury (Hg(II)), methylmecury and ethylmercury) was investigated. Parameters including concentrations and pH of the mobile phase were optimized. The separation and re-equilibration time was attained within 20min. Meanwhile, a sequential extraction method for arsenic and mercury in rice was tested. Subsequently, 1% HNO3 microwave-assisted extraction was chosen. Calibration curves based on peak area measurements were linear with correlation coefficient greater than 0.9958 for each species in the range studied. The detection limits of the species were in the range of 0.84-2.41μg/L for arsenic and 0.01-0.04μg/L for mercury, respectively. The proposed method was then successfully applied for the simultaneous determination of arsenic and mercury species in rice flour standard material and two kinds of rice from local markets. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Speciation of mercury in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Jia Xiaoyu; Han Yi; Liu Xinli [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Science, Changchun 130022 (China); Graduate School of Chinese Academy of Sciences, Beijing 100039 (China); Duan Taicheng, E-mail: tcduan@ciac.jl.cn [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Science, Changchun 130022 (China); Chen Hangting, E-mail: htchen@ciac.jl.cn [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Science, Changchun 130022 (China)

    2011-01-15

    The dispersive liquid-liquid microextraction (DLLME) combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry for the speciation of mercury in water samples was described. Firstly methylmercury (MeHg{sup +}) and mercury (Hg{sup 2+}) were complexed with sodium diethyldithiocarbamate, and then the complexes were extracted into carbon tetrachloride by using DLLME. Under the optimized conditions, the enrichment factors of 138 and 350 for MeHg{sup +} and Hg{sup 2+} were obtained from only 5.00 mL sample solution. The detection limits of the analytes (as Hg) were 0.0076 ng mL{sup -1} for MeHg{sup +} and 0.0014 ng mL{sup -1} for Hg{sup 2+}, respectively. The relative standard deviations for ten replicate measurements of 0.5 ng mL{sup -1} MeHg{sup +} and Hg{sup 2+} were 6.9% and 4.4%, respectively. Standard reference material of seawater (GBW(E)080042) was analyzed to verify the accuracy of the method and the results were in good agreement with the certified values. Finally, the developed method was successfully applied for the speciation of mercury in three environmental water samples.

  15. Mercury speciation in thawed out and refrozen fish samples by gas chromatography coupled to inductively coupled plasma mass spectrometry and atomic fluorescence spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Krystek, Petra; Ritsema, Rob [National Institute for Public Health and the Environment (RIVM), Laboratory for Analytical Chemistry, Bilthoven (Netherlands)

    2005-01-01

    Different sub-sampling procedures were applied for the determination of mercury species (as total mercury Hg, methylmercury MeHg{sup +} and inorganic mercury Hg{sup 2+}) in frozen fish meat. Analyses were carried out by two different techniques. After the sample material was pre-treated by microwave digestion, atomic fluorescence spectroscopy (AFS) was used for the determination of total Hg. Speciation analysis was performed according to the following procedure: dissolution of sample material in tetramethylammonium hydroxide (TMAH), derivatisation with sodium tetraethylborate (NaBEt{sub 4}), extraction into isooctane and measurement with gas chromatography inductively coupled plasma mass spectrometry (GC-ICPMS) for the identification and quantification of methylmercury (MeHg{sup +}) and inorganic mercury (Hg{sup 2+}). The concentration range of total Hg measured in the shark fillets is between 0.9 and 3.6 {mu}g g{sup -1} thawed out shark fillet. Speciation analysis leads to {>=}94% Hg present as MeHg{sup +}. Homogeneity, storage conditions and stability of analytical species and sample materials have great influence on analytical results. Sub-sampling of half-frozen/partly thawed out fish and analysis lead to significantly different concentrations, which are on average a factor of two lower. (orig.)

  16. Chemical speciation analysis for bromine in tap water by ion chromatography/inductively coupled plasma-mass spectrometry and electrospray ionization-mass spectrometry

    International Nuclear Information System (INIS)

    Kurata, Keigo; Suzuki, Yoshinari; Furuta, Naoki

    2010-01-01

    Bromide compounds in tap water were measured by using a hyphenated technique of ion chromatography coupled with inductively coupled plasma - mass spectrometry (IC/ICP-MS) and electrospray ionization mass spectrometry (ESI-MS). We identified bromide ion (Br - ), bromate ion (BrO 3 - ), bromochloroacetic acid (BCAA), dibromoacetic acid (DBAA) and bromodichloroacetic acid (BDCAA) by standard addition methods with IC/ICP-MS. Moreover, we identified BCAA and BDCAA by ESI-MS after separation with IC. Br - , BrO 3 - , BCAA, DBAA and BDCAA in tap water collected from around Tokyo area were quantified by IC/ICP-MS. The maximum concentration of BrO 3 - (1.8 ng mL -1 ) was observed in tap water collected from Bunkyo-ku, although this concentration was lower than 10 ng mL -1 , which is the regulated concentration in Japan. DBAA, which is regulated by United States Environmental Protection Agency, was detected in tap water collected from all sites, except for Ome. However, since BrO 3 - and DBAA are toxic, it is necessary to continue monitoring bromide compounds in tap water. (author)

  17. Speciation Analysis of Trace Mercury in Sea Cucumber Species of Apostichopus japonicus Using High-Performance Liquid Chromatography Conjunction With Inductively Coupled Plasma Mass Spectrometry.

    Science.gov (United States)

    Liu, Hao; Luo, Jiaoyang; Ding, Tong; Gu, Shanyong; Yang, Shihai; Yang, Meihua

    2018-03-25

    In this paper, a simple and cost-effective method using high-performance liquid chromatography in conjunction with inductively coupled plasma mass spectrometry with a rapid ultrasound-assisted extraction was used for analysis speciation of trace mercury in sea cucumber species of Apostichopus japonicus. The effective separation of inorganic mercury, methylmercury, and ethylmercury was achieved within 10 min using Agilent ZORBAX SB-C 18 analytical and guard columns with an isocratic mobile phase consisting of 8% methanol and 92% H 2 O containing 0.12% L-cysteine (m/v) and 0.01 mol/L ammonium acetate. Mercury species were extracted from A. japonicus samples using a solution containing 2-mercaptoethanol, L-cysteine, and hydrochloric acid and sonicating for 0.5 h. The limits of detection of inorganic mercury, methylmercury, and ethylmercury were 0.12, 0.08, and 0.20 μg/L, and the minimum detectable concentrations (measured at 0.500 g sample volume in 10.00 mL) were 2.4, 1.6, and 4.0 μg/kg, respectively. Analysis of a scallop certified reference material (GBW 10024) revealed accordance between the experimental and certified values. This study provides a reference for the evaluation of mercury speciation in sea cucumber and other seafood.

  18. Actinides analysis in emergency situation by on-line coupling between a calix[6]arene-based chromatography column and an Inductively Coupled Plasma-Mass Spectrometer

    International Nuclear Information System (INIS)

    Baghdadi, Sarah

    2015-01-01

    In the event of a nuclear crisis, involving actinides (U, Pu, Am) it is important to have fast analysis methods available in order to identify people that could be contaminated. Usually, they are performed in urine or faeces. Even though, analytical methods used with alpha detection are reliable they are lengthy and tedious to set up. This work consisted in developing an on-line coupling method between a calix[6]arene-based chromatography column and an inductively coupled plasma mass spectrometer (ICP-MS). To do so, a speciation study of actinides in mineralised urine was developed to understand the chemical equilibria happening during the actinides extraction. A protocol was elaborated to extract simultaneously all three actinides at pH = 5, then co-elute them with 0.25 mol.L -1 H 3 PO 4 . Recovery was 56 %, 74 % and 85 % for U, Pu and Am respectively. The column was then coupled to the ICP-MS. A parameter study helped defining mineralisation duration, extraction and elution flow-rates. It was then possible to propose an on-line coupling system allowing reaching detection limits lower than 0.5 mBq.L-1 for 238 U and 243 Am and lower than 5 mBq.L -1 for 239 Pu and 241 Am, for analysis duration lower than 6 hours. These analytical performances show the interest of this technique for a use in a nuclear crisis situation. (author)

  19. Determination of Tributyltin in Seafood Based on Magnetic Molecularly Imprinted Polymers Coupled with High-Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Hua Yang

    2017-01-01

    Full Text Available In this study, Fe3O4 was adopted as a carrier for surface molecular imprinting with two-stage polymerization. First, the functional monomer (methacrylic acid, MAA was modified on the surface of Fe3O4, which was then polymerized with the template molecule (tributyltin, TBT, cross linking agent (ethylene glycol dimethacrylate, EGDMA, and porogen (acetonitrile, hereby successfully preparing Fe3O4@MIPs prone to specifically identify TBT. The physical properties of Fe3O4@MIPs were then characterized, and adsorption and selection capacities were also assessed. Compared with conventional imprinting polymers, this magnetic molecular imprinting polymer (MIP displayed significantly increased and more specific adsorption. Meanwhile, its pretreatment was simpler and faster due to magnetic separation characteristics. Using magnetic MIPs as adsorbents for enrichment and separation, detection limit, recovery rate, and linear range were 1.0 ng g−1, 79.74–95.72%, and 5 ng g−1~1000 ng g−1, respectively, for a number of seafood samples. High-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS was used to analyze Tegillarca granosa, mussels, large yellow croaker, and other specimens, with recovery rates of 79.74–95.72% and RSD of 1.3%–4.7%. Overall, this method has a shorter total analysis time, lower detection limit, and wider linear range and can be more effectively applied to determine MAA in seawater and seafood.

  20. Method development for speciation analysis of nanoparticle and ionic forms of gold in biological samples by high performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Malejko, Julita; Świerżewska, Natalia; Bajguz, Andrzej; Godlewska-Żyłkiewicz, Beata

    2018-04-01

    A new method based on coupling high performance liquid chromatography (HPLC) to inductively coupled plasma mass spectrometry (ICP MS) has been developed for the speciation analysis of gold nanoparticles (AuNPs) and dissolved gold species (Au(III)) in biological samples. The column type, the composition and the flow rate of the mobile phase were carefully investigated in order to optimize the separation conditions. The usefulness of two polymeric reversed phase columns (PLRP-S with 100 nm and 400 nm pore size) to separate gold species were investigated for the first time. Under the optimal conditions (PLRP-S400 column, 10 mmol L-1 SDS and 5% methanol as the mobile phase, 0.5 mL min-1 flow rate), detection limits of 2.2 ng L-1 for Au(III), 2.8 ng L-1 for 10 nm AuNPs and 3.7 ng L-1 for 40 nm AuNPs were achieved. The accuracy of the method was proved by analysis of reference material RM 8011 (NIST) of gold nanoparticles of nominal diameter of 10 nm. The HPLC-ICP MS method has been successfully applied to the detection and size characterization of gold species in lysates of green algae Acutodesmus obliquus, typical representative of phytoplankton flora, incubated with 10 nm AuNPs or Au(III).

  1. Arsenic Species in Edible Seaweeds Using In Vitro Biomimetic Digestion Determined by High-Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Yan-Fang Zhao

    2014-01-01

    Full Text Available Arsenite [As (III], arsenate [As (V], methylarsonate (MMA, and dimethylarsinate (DMA in five edible seaweeds (the brown algae Laminaria japonica, red algae Porphyra yezoensis, brown algae Undaria pinnatifida, brown algae Hizikia fusiformis, and green algae Enteromorpha prolifera were analyzed using in vitro digestion method determined by high-performance liquid chromatography inductively coupled plasma mass spectrometry. The results showed that DMA was found in the water extracts of all samples; As (III were detected in L. japonica and U. pinnatifida and about 23.0 and 0.15 mg/kg of As (V were found in H. fusiformis and E. prolifera respectively. However, after the gastrointestinal digestion, As (V was not detected in any of the five seaweeds. About 0.19 and 1.47 mg/kg of As (III was detected in the gastric extracts of L. japonica and H. fusiformis, respectively, and about 0.31 and 0.10 mg/kg of As (III were extracted from the intestinal extracts of Porphyra yezoensis and U. pinnatifida, respectively. The present results successfully reveal the differences of As species and levels in the water and biomimetic extracts of five edible seaweeds. The risk assessment of the inorganic arsenic in the five edible seaweeds based on present data showed almost no hazards to human health.

  2. Speciation of mercury in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Jia Xiaoyu; Han Yi; Liu Xinli; Duan Taicheng; Chen Hangting

    2011-01-01

    The dispersive liquid-liquid microextraction (DLLME) combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry for the speciation of mercury in water samples was described. Firstly methylmercury (MeHg + ) and mercury (Hg 2+ ) were complexed with sodium diethyldithiocarbamate, and then the complexes were extracted into carbon tetrachloride by using DLLME. Under the optimized conditions, the enrichment factors of 138 and 350 for MeHg + and Hg 2+ were obtained from only 5.00 mL sample solution. The detection limits of the analytes (as Hg) were 0.0076 ng mL -1 for MeHg + and 0.0014 ng mL -1 for Hg 2+ , respectively. The relative standard deviations for ten replicate measurements of 0.5 ng mL -1 MeHg + and Hg 2+ were 6.9% and 4.4%, respectively. Standard reference material of seawater (GBW(E)080042) was analyzed to verify the accuracy of the method and the results were in good agreement with the certified values. Finally, the developed method was successfully applied for the speciation of mercury in three environmental water samples.

  3. Protein quantitation using Ru-NHS ester tagging and isotope dilution high-pressure liquid chromatography-inductively coupled plasma mass spectrometry determination.

    Science.gov (United States)

    Liu, Rui; Lv, Yi; Hou, Xiandeng; Yang, Lu; Mester, Zoltan

    2012-03-20

    An accurate, simple, and sensitive method for the direct determination of proteins by nonspecies specific isotope dilution and external calibration high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) is described. The labeling of myoglobin (17 kDa), transferrin (77 kDa), and thyroglobulin (670 kDa) proteins was accomplished in a single-step reaction with a commercially available bis(2,2'-bipyridine)-4'-methyl-4-carboxybipyridine-ruthenium N-succinimidyl ester-bis(hexafluorophosphate) (Ru-NHS ester). Using excess amounts of Ru-NHS ester compared to the protein concentration at optimized labeling conditions, constant ratios for Ru to proteins were obtained. Bioconjugate solutions containing both labeled and unlabeled proteins as well as excess Ru-NHS ester reagent were injected onto a size exclusion HPLC column for separation and ICPMS detection without any further treatment. A (99)Ru enriched spike was used for nonspecies specific ID calibration. The accuracy of the method was confirmed at various concentration levels. An average recovery of 100% ± 3% (1 standard deviation (SD), n = 9) was obtained with a typical precision of better than 5% RSD at 100 μg mL(-1) for nonspecies specific ID. Detection limits (3SD) of 1.6, 3.2, and 7.0 fmol estimated from three procedure blanks were obtained for myoglobin, transferrin, and thyroglobulin, respectively. These detection limits are suitable for the direct determination of intact proteins at trace levels. For simplicity, external calibration was also tested. Good linear correlation coefficients, 0.9901, 0.9921, and 0.9980 for myoglobin, transferrin, and thyroglobulin, respectively, were obtained. The measured concentrations of proteins in a solution were in good agreement with their volumetrically prepared values. To the best of our knowledge, this is the first application of nonspecies specific ID for the accurate and direct determination of proteins using a Ru-NHS ester

  4. Determination of tetrabromobisphenol-A/S and their main derivatives in water samples by high performance liquid chromatography coupled with inductively coupled plasma tandem mass spectrometry.

    Science.gov (United States)

    Liu, Lihong; Liu, Aifeng; Zhang, Qinghua; Shi, Jianbo; He, Bin; Yun, Zhaojun; Jiang, Guibin

    2017-05-12

    As the most widely used brominated flame retardants (BFRs), Tetrabromobisphenol-A (TBBPA) as well as its alternative Tetrabromobisphenol-S (TBBPS) and their derivatives have raised wide concerns due to their adverse effects on human health and hence the sensitive detection of those BFRs was urgently needed. Herein, a novel analytical method based on high-performance liquid chromatography (HPLC) coupled with inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) has been developed for the determination of TBBPA/S and their derivatives, including TBBPA-bis(2-hydroxyethyl ether) (TBBPA-BHEE), TBBPA-bis(allylether) (TBBPA-BAE), TBBPA-bis(glycidyl ether) (TBBPA-BGE), TBBPA-bis(2,3-dibromopropyl ether) (TBBPA-BDBPE) and TBBPS-bis(2,3-dibromopropyl ether) (TBBPS-BDBPE) in water samples. After optimization, the TBBPA/S and their derivatives, especially the TBBPA-BAE and TBBPA-BDBPE were simultaneously and sensitively quantified by determination of bromine (m/z=79) by using the ICP-MS. The instrument limits of detection (LODs) for the TBBPA, TBBPA-BHEE, TBBPA-BGE, TBBPA-BAE, TBBPA-BDBPE, TBBPS and TBBPS-BDBPE were determined to be 0.12, 0.14, 0.19, 0.14, 0.12, 0.17 and 0.13μgL -1 , respectively, which was close to or much better than the reported methods. The relative standard deviations (RSDs, n=5) of peak area and retention time were better than 2.2% and 0.2% for intra-day analysis, indicating good repeatability and high precision. The proposed method had been successfully applied for the analysis of TBBPA/S and their derivatives in water samples with satisfactory recoveries (67.7%-113%). Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Arsenic species determination in human scalp hair by pressurized hot water extraction and high performance liquid chromatography-inductively coupled plasma-mass spectrometry.

    Science.gov (United States)

    Morado Piñeiro, Andrés; Moreda-Piñeiro, Jorge; Alonso-Rodríguez, Elia; López-Mahía, Purificación; Muniategui-Lorenzo, Soledad; Prada-Rodríguez, Darío

    2013-02-15

    Analytical methods for the determination of total arsenic and arsenic species (mainly As(III) and As(V)) in human scalp hair have been developed. Inductively coupled plasma-mass spectrometry (ICP-MS) and high performance liquid chromatography (HPLC) coupled to ICP-MS have been used for total arsenic and arsenic species determination, respectively. The proposed methods include a "green", fast, high efficient and automated species leaching procedure by pressurized hot water extraction (PHWE). The operating parameters for PHWE including modifier concentration, extraction temperature, static time, extraction steps, pressure, mean particle size, diatomaceous earth (DE) mass/sample mass ratio and flush volume were studied using design of experiments (Plackett-Burman design PBD). Optimum condition implies a modifier concentration (acetic acid) of 150 mM and powdered hair samples fully mixed with diatomaceous earth (DE) as a dispersing agent at a DE mass/sample mass ratio of 5. The extraction has been carried out at 100°C and at an extraction pressure of 1500 psi for 5 min in four extraction step. Under optimised conditions, limits of quantification of 7.0, 6.3 and 50.3 ng g(-1) for total As, As(III) and As(V), respectively were achieved. Repeatability of the overall procedure (4.4, 7.2 and 2.1% for total As, As(III) and As(V), respectively) was achieved. The analysis of GBW-07601 (human hair) certified reference material was used for validation. The optimised method has been finally applied to several human scalp hair samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Determination and pharmacokinetic properties of arsenic speciation in Xiao-Er-Zhi-Bao-Wan by high-performance liquid chromatography with inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Han, Xu; Luo, Jiaoyang; Zhou, Wenju; Yang, Shihai; Yang, Meihua

    2016-10-01

    A method of high performance liquid chromatography with a Hamilton PRP-X100 ion-exchange column (250 × 4.1 mm id, 10 μm) coupled to inductively coupled plasma mass spectrometry was employed to generate a full concentration-time profile of arsenic speciation after oral administration. The results exhibited good linearity and revealed that, in the pills, the average arsenic concentration was 10105.4 ± 380.7 mg/kg, and in the water extraction solution, the inorganic As(III) and As(V) concentrations were 220.1 ± 12.6 and 45.5 ± 2.3 mg/kg, respectively. No trace of monomethyl arsenic acid was detected in any of the plasma samples. We then successfully applied the established methodology to examine the pharmacokinetics of arsenic speciation. The resulting data revealed that, after oral administration in rats, the plasma concentration of each arsenic species reached C max shortly after initial dosing, and that the distribution and elimination of As(V) was faster than that of As(III) and dimethyl arsenic acid. Additionally, the t 1/2 values of As(V), As(III), and dimethyl arsenic acid were 3.4 ± 1.6, 14.3 ± 4.0, and 19.9 ± 1.6 h, respectively. This study provides references for the determination of arsenic speciation in mineral-containing medicines and could serve as a useful tool in measuring the true toxicity in traditional medicines that contain them. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Simultaneous separation and determination of six arsenic species in rice by anion-exchange chromatography with inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Ma, Li; Yang, Zhaoguang; Tang, Jie; Wang, Lin

    2016-06-01

    The simultaneous separation and determination of arsenite As(III), arsenate As(V), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB), and arsenocholine (AsC) in rice samples have been carried out in one single anion-exchange column run by high-performance liquid chromatography with inductively coupled plasma mass spectrometry. To estimate the effect of variables on arsenic (As) speciation, the chromatographic conditions including type of competing anion, ionic strength, pH of elution buffer, and flow rate of mobile phase have been investigated by a univariate approach. Under the optimum chromatographic conditions, baseline separation of six As species has been achieved within 10 min by gradient elution program using 4 mM NH4 HCO3 at pH 8.6 as mobile phase A and 4 mM NH4 HCO3 , 40 mM NH4 NO3 at pH 8.6 as mobile phase B. The method detection limits for As(III), As(V), MMA, DMA, AsB, and AsC were 0.4, 0.9, 0.2, 0.4, 0.5, and 0.3 μg/kg, respectively. The proposed method has been applied to separation and quantification of As species in real rice samples collected from Hunan Province, China. The main As species detected in all samples were As(III), As(V) and DMA, with inorganic As accounting for over 80% of total As in these samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Elevated metallothionein-bound cadmium concentrations in urine from bladder carcinoma patients, investigated by size exclusion chromatography-inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Christian [Department of Molecular Trace Element Research in the Life Sciences, Helmholtz Centre Berlin for Materials and Energy, Glienicker Str. 100, 14109 Berlin (Germany)], E-mail: wolf@helmholtz-berlin.de; Strenziok, Romy [Department of Urology, Charite University Medicine Berlin, Campus Benjamin Franklin, Hindenburgdamm 30, 12203 Berlin (Germany); Kyriakopoulos, Antonios [Department of Molecular Trace Element Research in the Life Sciences, Helmholtz Centre Berlin for Materials and Energy, Glienicker Str. 100, 14109 Berlin (Germany)

    2009-01-12

    Cadmium is discussed as being involved in the development of transitional cell carcinoma (TCC) of the bladder and can be observed in urine of these patients. Investigations of urinary samples from bladder cancer patients and normal controls were carried out with special emphasis on metallothionein (MT)-bound cadmium. Compounds that are constituents of urine were separated in urine samples by means of size exclusion chromatography and cadmium was monitored continuously with a hyphenated inductively coupled plasma mass spectrometry (ICP-MS) system. MT-bound cadmium was quantified by peak area integration, taking into account the intensity of the rhodium signal which was added continuously before ICP-MS detection. The obtained results show that urinary cadmium is predominantly bound to the observed MT-fraction. The median of the MT-bound cadmium concentration in the control group was found to be 0.8 {mu}g L{sup -1} whereas the cancer group has a median of 1.8 {mu}g L{sup -1}. The variance of the data in the cancer group is much higher than in the controls. However, the urinary MT-bound cadmium is significantly elevated in the cancer group; odds-ratio test: 7.11 (95% C.I.: 1.89-26.80), taking into account the total protein content. Due to the fact that only one main cadmium-containing fraction was observed, there is no necessity to separate the MT-fraction before cadmium determination in urine samples in future studies.

  9. Measurement of isotopic composition of lanthanides in reprocessing process solutions by high-performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC/ICP-MS)

    International Nuclear Information System (INIS)

    Okano, Masanori; Jitsukata, Shu; Kuno, Takehiko; Yamada, Keiji

    2011-01-01

    Isotopic compositions of fission products in process solutions and wastes in a reprocessing plant are valuable to proceed safety study of the solutions and research/development concerning treatment/disposal of the wastes. The amount of neodymium-148 is a reliable indication to evaluate irradiation history. The isotopic compositions of samarium and gadolinium in high radioactive wastes are referred to as essential data to evaluate environmental impact in geological repositories. However, pretreatment of analysis must be done with complicated chemical separation such as solvent extraction and ion exchange. The actual measurement data of isotopic compositions of lanthanides comparable to the one of actinides in spent fuel reprocessing process has not been obtained enough. Rapid and high sensitive analytical technique based on high-performance liquid chromatography (HPLC) with an inductively coupled plasma mass spectrometry (ICP-MS) has been developed for the measurement of isotopic compositions of lanthanides in spent fuel reprocessing solutions. HPLC/ICP-MS measurement system was customized for a glove-box to be applied to the radioactive solutions. The cation exchange chromatographic columns (Shim-pack IC-C1) and injection valve (20μL) were located inside of the glove-box except the chromatographic pump. The elements of lanthanide group were separated by a gradient program of HPLC with α-hydroxyisobutyric acid. Isotopic compositions of lanthanides in eluate was sequentially analyzed by a quadruple ICP-MS. Optimization of parameter of HPLC and ICP-MS measurement system was examined with standard solutions containing 14 lanthanide elements. The elements of lanthanides were separated by HPLC and detected by ICP-MS within 25 minutes. The detection limits of Nd-146, Sm-147 and Gd-157 were 0.37 μg L -1 , 0.69 μg L -1 and 0.47 μg L -1 , respectively. The analytical precision of the above three isotopes was better than 10% for standard solutions of 100 μg L -1 with

  10. Determination of {sup 236}U in environmental samples by single extraction chromatography coupled to triple-quadrupole inductively coupled plasma-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Guosheng [Department of Radiation Chemistry, Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki, Aomori, 036-8564 (Japan); Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences (China); Beijing Engineering Research Center of Radiographic Techniques and Equipment, Beijing, 100049 (China); Tazoe, Hirofumi [Department of Radiation Chemistry, Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki, Aomori, 036-8564 (Japan); Yamada, Masatoshi, E-mail: myamada@hirosaki-u.ac.jp [Department of Radiation Chemistry, Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki, Aomori, 036-8564 (Japan)

    2016-11-09

    In order to measure trace {sup 236}U and {sup 236}U/{sup 238}U in environmental samples with a high matrix effect, a novel and simple method was developed that makes the digestion and purification procedures compatible with advanced triple-quadrupole inductively coupled plasma-mass spectrometry. A total dissolution of sample with HF + HNO{sub 3} + HClO{sub 4} was followed by chromatographic separation with a single resin column containing normal type DGA resin (N,N,N′,N’-tetra-n-octyldiglycolamide) as the extractant system. The analytical accuracy and precision of {sup 236}U/{sup 238}U ratios, measured as {sup 236}U{sup 16}O{sup +}/{sup 238}U{sup 16}O{sup +}, were examined by using the reference materials IAEA-135, IAEA-385, IAEA-447, and JSAC 0471. The low method detection limit (3.50 × 10{sup −6} Bq kg{sup −1}) makes it possible to perform routine monitoring of environmental {sup 236}U due to global fallout combined with the Fukushima Daiichi Nuclear Power Plant accident fallout (>10{sup −5} Bq kg{sup −1}). Finally, the developed method was successfully applied to measure {sup 236}U/{sup 238}U ratios and {sup 236}U activities in soil samples contaminated by the accident. The low {sup 236}U/{sup 238}U atom ratios ((1.50–13.5) × 10{sup −8}) and {sup 236}U activities ((2.25–14.1) × 10{sup −2} mBq kg{sup −1}) indicate {sup 236}U contamination was mainly derived from global fallout in the examined samples. - Highlights: • A simple {sup 236}U/{sup 238}U analytical method has been developed. • The separation required just one DGA column chromatography. • {sup 236}U/{sup 238}U atom ratios in soil were measured by ICP-MS/MS. • {sup 236}U/{sup 238}U atom ratios of (1.50–13.5) × 10{sup −8} were observed in Japanese samples. • {sup 236}U activities of (2.25–14.1) × 10{sup −2} mBq kg{sup −1} were found in Japanese samples.

  11. Ion-pairing reversed-phase chromatography coupled to inductively coupled plasma mass spectrometry as a tool to determine mercurial species in freshwater fish.

    Science.gov (United States)

    Cheng, Heyong; Chen, Xiaopan; Shen, Lihuan; Wang, Yuanchao; Xu, Zigang; Liu, Jinhua

    2018-01-05

    Most of analytical community is focused on reversed phase high performance liquid chromatography (RP-HPLC) for mercury speciation by employing mobile phases comprising of high salts and moderate amounts of organic solvents. This study aims at rapid mercury speciation analysis by ion-pairing RP-HPLC with inductively coupled plasma mass spectrometry (ICP-MS) detection only using low salts for the sake of green analytical chemistry. Two ion-pairing HPLC methods were developed on individual usage of positively and negatively charged ion-pairing reagents (tetrabutylammonium hydroxide -TBAH and sodium dodecylbenzene sulfonate -SDBS), where sodium 3-mercapto-1-propysulfonate (MPS) and l-cysteine (Cys) were individually added in mobile phases to transform mercury species into negative and positive Hg-complexes for good resolution. Addition of phenylalanine was also utilized for rapid baseline separation in combination of short C 18 guard columns. Optimum mobile phases of 2.0mM SDBS+2.0mM Cys+1.0mM Phe (pH 3.0) and 4.0mM TBAH+2.0mM MPS+2.0mM Phe (pH 6.0) both achieved baseline separation of inorganic mercury (Hg 2+ ), methylmercury (MeHg), ethylmercury (EtHg) and phenylmercury (PhHg) on two consecutive 12.5-mm C 18 columns. The former mobile phase was selected for mercury speciation in freshwater fish because of short separation time (3.0min). Detection limits of 0.015 for Hg 2+ , 0.014 for MeHg, 0.028 for EtHg and 0.042μgL -1 for PhHg were obtained along with satisfactory precisions of peak height and area (1.0-2.8% for 5.0μgL -1 Hg-mixture standard). Good accordance of determined values of MeHg and total mercury in certified reference materials of fish tissue (GBW 10029) and tuna fish (BCR-463) with certified values as well as good recoveries (91-106%) proved good accuracy of the proposed method. An example application to freshwater fish indicated its potential in routine analysis, where MeHg was presented at 3.7-20.3μgkg -1 as the dominate species. Copyright © 2017

  12. Development of an analytical method for the determination of polybrominated diphenyl ethers in sewage sludge by the use of gas chromatography coupled to inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Novak, Petra; Zuliani, Tea; Milačič, Radmila; Ščančar, Janez

    2016-01-01

    Polybrominated diphenyl ethers (PBDEs) are flame retardants. As a consequence of their widespread use, they have been released into the environment. PBDEs are lipophilic organic contaminants that enter wastewater treatment plants (WWTPs) from urban, agricultural and industrial discharges. Because of their low aqueous solubility and resistance to biodegradation, up to 90% of the PBDEs are accumulated in the sewage sludge during the wastewater treatment. To assess the possibilities for sludge re-use, a reliable determination of the concentrations of these PBDEs is of crucial importance. Six PBDE congeners (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153 and BDE 154) are listed as priority substances under the EU Water Framework Directive. In the present work a simple analytical method with minimal sample-preparation steps was developed for a sensitive and reliable determination of the six PBDEs in sewage sludge by the use of gas chromatography coupled to inductively coupled plasma mass spectrometry (GC-ICP-MS). For this purpose an extraction procedure was optimised. Different extracting agents (methanol (MeOH), acetic acid (AcOH)/MeOH mixture (3:1) and 0.1 mol L"−"1 hydrochloric acid (HCl) in MeOH) followed by the addition of a Tris-citrate buffer (co-extracting agent) and iso-octane were applied under different modes of extraction (mechanical shaking, microwave- and ultrasound-assisted extraction). Mechanical shaking or the microwave-assisted extraction of sewage sludge with 0.1 mol L"−"1 HCl in MeOH and the subsequent addition of the Tris-citrate buffer and the iso-octane extracted the PBDEs from the complex sludge matrix most effectively. However, due to easier sample manipulation during the extraction step, mechanical shaking was used. The PBDEs in the organic phase were quantified with GC-ICP-MS by applying a standard addition calibration method. The spike recovery test (recoveries between 95 and 104%) and comparative analyses with the species-specific isotope

  13. Development of an analytical method for the determination of polybrominated diphenyl ethers in sewage sludge by the use of gas chromatography coupled to inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Novak, Petra [Department of Environmental Sciences, Jožef Stefan Institute, Jamova 39, 1000, Ljubljana (Slovenia); Jožef Stefan International Postgraduate School, Jamova 39, 1000, Ljubljana (Slovenia); Zuliani, Tea [Department of Environmental Sciences, Jožef Stefan Institute, Jamova 39, 1000, Ljubljana (Slovenia); Milačič, Radmila [Department of Environmental Sciences, Jožef Stefan Institute, Jamova 39, 1000, Ljubljana (Slovenia); Jožef Stefan International Postgraduate School, Jamova 39, 1000, Ljubljana (Slovenia); Ščančar, Janez, E-mail: janez.scancar@ijs.si [Department of Environmental Sciences, Jožef Stefan Institute, Jamova 39, 1000, Ljubljana (Slovenia); Jožef Stefan International Postgraduate School, Jamova 39, 1000, Ljubljana (Slovenia)

    2016-04-07

    Polybrominated diphenyl ethers (PBDEs) are flame retardants. As a consequence of their widespread use, they have been released into the environment. PBDEs are lipophilic organic contaminants that enter wastewater treatment plants (WWTPs) from urban, agricultural and industrial discharges. Because of their low aqueous solubility and resistance to biodegradation, up to 90% of the PBDEs are accumulated in the sewage sludge during the wastewater treatment. To assess the possibilities for sludge re-use, a reliable determination of the concentrations of these PBDEs is of crucial importance. Six PBDE congeners (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153 and BDE 154) are listed as priority substances under the EU Water Framework Directive. In the present work a simple analytical method with minimal sample-preparation steps was developed for a sensitive and reliable determination of the six PBDEs in sewage sludge by the use of gas chromatography coupled to inductively coupled plasma mass spectrometry (GC-ICP-MS). For this purpose an extraction procedure was optimised. Different extracting agents (methanol (MeOH), acetic acid (AcOH)/MeOH mixture (3:1) and 0.1 mol L{sup −1} hydrochloric acid (HCl) in MeOH) followed by the addition of a Tris-citrate buffer (co-extracting agent) and iso-octane were applied under different modes of extraction (mechanical shaking, microwave- and ultrasound-assisted extraction). Mechanical shaking or the microwave-assisted extraction of sewage sludge with 0.1 mol L{sup −1} HCl in MeOH and the subsequent addition of the Tris-citrate buffer and the iso-octane extracted the PBDEs from the complex sludge matrix most effectively. However, due to easier sample manipulation during the extraction step, mechanical shaking was used. The PBDEs in the organic phase were quantified with GC-ICP-MS by applying a standard addition calibration method. The spike recovery test (recoveries between 95 and 104%) and comparative analyses with the species

  14. Development of anion-exchange/reversed-phase high performance liquid chromatography-inductively coupled plasma-mass spectrometry methods for the speciation of bio-available iodine and bromine from edible seaweed.

    Science.gov (United States)

    Romarís-Hortas, Vanessa; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio

    2012-05-04

    Anion exchange high performance liquid chromatography hyphenated with inductively coupled plasma-mass spectrometry has been novelly applied to assess inorganic (iodide and iodate) and organic (3-iodotyrosine - MIT, and 3,5-diiodotyrosine - DIT) iodine species in a single chromatographic run. The optimized operating conditions (Dionex IonPac AS7, gradient elution with 175 mM ammonium nitrate plus 15% (v/v) methanol, pH 3.8, as a mobile phase and flow rates within the 0.5-1.5 mL min(-1) range) have also been used to perform inorganic bromine speciation analysis (bromide and bromate). The developed method has been applied for determining the bio-available contents of iodine and bromine species in dialyzates from edible seaweed. Reverse phase high performance liquid chromatography (Zorbax Eclipse XDB-C8, gradient elution with 0.2% (m/m) acetic acid, and 0.2% (m/m) acetic acid in methanol, as mobile phases, and a constant flow rate of 0.75 mL min(-1)) also hyphenated with inductively coupled plasma-mass spectrometry was used to confirm the presence of organic iodine species (MIT and DIT) in the dialyzates. The verification of the presence of iodinated amino acids (MIT and DIT) in the extracts was also performed by reverse phase high performance liquid chromatography-electrospray ionization-mass spectrometry (LTQ Orbitrap). The developed methods have provided good repeatability (RSD values lower than 10% for both anion exchange and reverse phase separations) and analytical recoveries within the 90-105% range for all cases. The in vitro bio-availability method consisted of a simulated gastric and an intestinal digestion/dialysis (10 kDa molecular weight cut-off - MWCO) two-stage procedure. Iodide and MIT were the main bio-available species quantified, whereas bromide was the major bromine species found in the extracts. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Measurement of elemental speciation by liquid chromatography -- inductively coupled plasma mass spectrometry (LC-ICP-MS) with the direct injection nebulizer (DIN)

    Energy Technology Data Exchange (ETDEWEB)

    Shum, Sam [Iowa State Univ., Ames, IA (United States)

    1993-05-01

    This thesis is divided into 4 parts: elemental speciation, speciation of mercury and lead compounds by microbore column LC-ICP-MS with direct injection nebulization, spatially resolved measurements of size and velocity distributions of aerosol droplets from a direct injection nebulizer, and elemental speciation by anion exchange and size exclusion chromatography with detection by ICP-MS with direct injection nebulization.

  16. Hydrophilic interaction chromatography with a focus on the drug-phosphate interaction in drug screening to determine the phospholipidosis induction risk.

    Science.gov (United States)

    Okamoto, Haruka; Hamaguchi, Ryohei; Kuroda, Yukihiro

    2017-04-15

    Cationic amphiphilic drugs (CADs) can induce the hyperaccumulation of phospholipids in cells and tissues. This side effect, which is known as drug-induced phospholipidosis, is sometimes problematic in the development and clinical use of CADs. It is known that CADs generally interact with phospholipids via both hydrophobic and acid-base interactions, and CADs with the larger affinity to phospholipid exhibit the larger induction risk. To develop a chromatographic assay system to predict the phospholipidosis-inducing potential with considering the acid-base interaction between CAD and phosphate group of phospholipid, hydrophilic interaction chromatographic (HILIC) methods were tested in this study. First, a PC HILIC column with phosphocholine groups on a packed material was used. The acid-base or other hydrophilic interactions to the stationary phase differed among basic drugs, and retention to the PC HILIC column did not accurately reflect the induction potential of phospholipidosis. As an alternative HILIC approach, the elution of CADs with the phosphate buffer from an amide column was tested. The elution effect, which is expressed as ratio of retention factors between different phosphate content in the mobile phase, closely correlated with the induction potential. Using the elution effect and retention factor to a reversed-phase HPLC column, the phospholipidosis-inducing drugs were clearly discriminated from the non-inducers. These results suggest that the proposed chromatographic approach can screen phospholipidosis-inducing drugs. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Arsenic speciation in seafood samples with emphasis on minor constituents. An investigation by high performance liquid chromatography with inductively coupled plasma mass spectrometric detection

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt; Pritzl, G.; Hansen, S. H.

    1993-01-01

    Extracts of 11 samples of shrimp, crab, fish, fish liver, shellfish and lobster digestive gland (hepatopancreas), including five certified reference materials, were investigated for their contents of arsenic compounds (arsenic speciation). The cation-exchange high performance liquid chromatography...... (as arsenic atom) relative to the total arsenic extracted from the samples were: arsenobetaine 19-98%, arsenocholine and trimethylarsine oxide 0-0.6% and the trimethylarsonium ion 0-2.2%. Additionally, an unknown arsenic species (U1) was present at 3.1-18% in the shellfish and in the lobster digestive...

  18. Speciation of four selenium compounds using high performance liquid chromatography with on-line detection by inductively coupled plasma mass spectrometry or flame atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Pedersen, Gitte Alsing; Larsen, Erik Huusfeldt

    1997-01-01

    An analytical method for the speciation of selenomethionine, selenocystine, selenite and selenate by high performance liquid chromatography (HPLC) with atomic spectrometric detection is presented. An organic polymeric strong anion exchange column was used as the stationary phase in combination...... spectrometry (ICP-MS). The signal-to-noise ratio of the FAAS detector was optimized using a hydrogen-argon entrained-air flame and a slotted-tube atom trap (STAT) in the flame. The limit of detection (3 sigma) achieved by the HPLC-FAAS system was 1 mg L-1 of selenium (100 mu L injections) for each of the four...

  19. Bead Injection Extraction Chromatography using High-capacity Lab-on-Valve as a Front End to Inductively Coupled Plasma Mass Spectrometry for Rapid Urine Radiobioassay

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2013-01-01

    A novel bead injection (BI) extraction chromatographic microflow system exploiting high-capacity lab-on-valve (LOV) platform coupled with inductively coupled plasma mass spectrometric detection is developed for rapid and automated determination of plutonium in human urine. A microconduit (1 m......L) incorporated within the LOV processing unit is loaded on-line with a metered amount of disposable extraction chromatographic resin (up to 330 mg of TEVA) through programmable beads transport. Selective capture and purification of plutonium onto the resin beads is then performed by pressure driven flow after...

  20. Inductively coupled plasma-mass spectrometry for elemental analysis and isotope ratio determinations in individual organic compounds separated by gas chromatography

    International Nuclear Information System (INIS)

    Chong, N.S.; Houk, R.S.

    1987-01-01

    A gas chromatograph (GC) with a packed column was interfaced to an inductively coupled plasma-mass spectrometer (ICP-MS) to yield atomic mass spectra from volatile organic compounds. Atomization of injected compounds was nearly complete and independent of molecular structure, so that elemental ratios could be determined. Detection limits were in the range 0.001 to 400 ng s -1 , depending on the ionization energy of the element and its abundance in the background spectrum. The relative standard deviation of measured isotope ratios varied from 0.4% for Br (i.e., a ratio close to unity) to 18% for N (a very large ratio). Thus, GC-ICP-MS provides elemental and isotope ratio information that is complementary to the molecular information derived from GC-MS with conventional ionization methods

  1. Rapid determination of {sup 135}Cs and precise {sup 135}Cs/{sup 137}Cs atomic ratio in environmental samples by single-column chromatography coupled to triple-quadrupole inductively coupled plasma-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Guosheng [Department of Radiation Chemistry, Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki, Aomori 036-8564 (Japan); Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Beijing Engineering Research Center of Radiographic Techniques and Equipment, Beijing 100049 (China); Tazoe, Hirofumi [Department of Radiation Chemistry, Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki, Aomori 036-8564 (Japan); Yamada, Masatoshi, E-mail: myamada@hirosaki-u.ac.jp [Department of Radiation Chemistry, Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki, Aomori 036-8564 (Japan)

    2016-02-18

    For source identification, measurement of {sup 135}Cs/{sup 137}Cs atomic ratio not only provides information apart from the detection of {sup 134}Cs and {sup 137}Cs, but it can also overcome the application limit that measurement of the {sup 134}Cs/{sup 137}Cs ratio has due to the short half-life of {sup 134}Cs (2.06 y). With the recent advancement of ICP-MS, it is necessary to improve the corresponding separation method for rapid and precise {sup 135}Cs/{sup 137}Cs atomic ratio analysis. A novel separation and purification technique was developed for the new generation of triple-quadrupole inductively coupled plasma-mass spectrometry (ICP-MS/MS). The simple chemical separation, incorporating ammonium molybdophosphate selective adsorption of Cs and subsequent single cation-exchange chromatography, removes the majority of isobaric and polyatomic interference elements. Subsequently, the ICP-MS/MS removes residual interference elements and eliminates the peak tailing effect of stable {sup 133}Cs, at m/z 134, 135, and 137. The developed analytical method was successfully applied to measure {sup 135}Cs/{sup 137}Cs atomic ratios and {sup 135}Cs activities in environmental samples (soil and sediment) for radiocesium source identification. - Highlights: • A simple {sup 135}Cs/{sup 137}Cs analytical method was developed. • The separation procedure was based on AMP adsorption and one column chromatography. • {sup 135}Cs/{sup 137}Cs was measured by ICP-MS/MS. • Decontamination factors for Ba, Mo, Sb, and Sn were improved. • {sup 135}Cs/{sup 137}Cs atomic ratios of 0.341–0.351 were found in Japanese soil samples.

  2. Sm isotope composition and Sm/Eu ratio determination in an irradiated 153Eu sample by ion exchange chromatography-quadrupole inductively coupled plasma mass spectrometry combined with double spike isotope dilution technique

    International Nuclear Information System (INIS)

    Bourgeois, M.; Isnard, H.; Gourgiotis, A.; Stadelmann, G.; Gautier, C.; Mialle, S.; Nonell, A.; Chartier, F.

    2011-01-01

    Within the framework of the research undertaken by the French Atomic Energy Commission on transmutation of long-lived radionuclides, targets of highly enriched actinides and fission products were irradiated in the fast neutron reactor Phenix. Precise and accurate measurements of the isotopic and elemental composition of the enriched elements are therefore required. In order to obtain the uncertainties of several per mil and to reduce handling time and exposure to analyst on radioactive material, the on-line coupling of ion exchange chromatography with quadrupole inductively coupled plasma mass spectrometry has been associated with the technique of the double spike isotope dilution. We present in this paper the results obtained on an irradiated sample of Europium oxide powder (enriched at 99.13% in 153 Eu). After irradiation of around 5 mg of Eu 2 O 3 powder the theoretical calculations predict the formation of several micrograms of gadolinium and samarium isotopes. In relation to the very high activity of the sample after irradiation and the very low quantity of Sm formed, the on-line ion exchange chromatography separation of Gd, Sm and Eu before Sm isotope ratio measurements has been developed for the quantification of the 152 Sm/ 153 Eu ratio. These on-line measurements were associated with the double spike isotope dilution technique after calibration of a 147 Sm/ 151 Eu spike solution. The external reproducibility of Sm isotopic ratios was determined to be around 0.5% (2 σ) resulting in a final uncertainty on the 152 Sm/ 153 Eu ratio of around 1% (2 σ). These on-line measurements present therefore a robust and high-throughput alternative to the thermal-ionisation mass spectrometry technique used so far in combination with off-line chromatographic separation, particularly in nuclear applications where characterisation of high activity sample solutions is required. (authors)

  3. Analysis of phosphorus herbicides by ion-pairing reversed-phase liquid chromatography coupled to inductively coupled plasma mass spectrometry with octapole reaction cell.

    Science.gov (United States)

    Sadi, Baki B M; Vonderheide, Anne P; Caruso, Joseph A

    2004-09-24

    A reversed phase ion-pairing high performance liquid chromatographic (RPIP-HPLC) method is developed for the separation of two phosphorus herbicides, Glufosinate and Glyphosate as well as Aminomethylphosphonic acid (AMPA), the major metabolite of Glyphosate. Tetrabutylammonium hydroxide is used as the ion-pairing reagent in conjunction with an ammonium acetate/acetic acid buffering system at pH 4.7. An inductively coupled plasma mass spectrometer (ICP-MS) is coupled to the chromatographic system to detect the herbicides at m/z = 31P. Historically, phosphorus has been recognized as one of the elements difficult to analyze in argon plasma. This is due to its relatively high ionization potential (10.5 eV) as well as the inherent presence of the polyatomic interferences 14N16O1H+ and 15N16O+ overlapping its only isotope at m/z = 31. An octapole reaction cell is utilized to minimize the isobaric polyatomic interferences and to obtain the highest signal-to-background ratio. Detection limits were found to be in the low ppt range (25-32 ng/l). The developed method is successfully applied to the analysis of water samples collected from the Ohio River and spiked with a standard compounds at a level of 20 microg/l.

  4. Ion-pair chromatography coupled to inductively coupled plasma-mass spectrometry (IPC-ICP-MS) as a method for thiomolybdate speciation in natural waters.

    Science.gov (United States)

    Lohmayer, Regina; Reithmaier, Gloria Maria Susanne; Bura-Nakić, Elvira; Planer-Friedrich, Britta

    2015-03-17

    Molybdenum precipitates preferentially under reducing conditions; therefore, its occurrence in sediment records is used as an indicator of paleoredox conditions. Although thiomolybdates (MoO4-xSx(2-) with x = 1-4) supposedly are necessary intermediates in the process of molybdenum precipitation under anoxic conditions, there is no information about their abundance in natural environments, because of a lack of element-specific methods with sufficiently low detection limits. Here, we optimized ion-pair chromatographic separation for coupling to an inductively coupled plasma-mass spectrometry detector (IPC-ICP-MS). 2-Propanol (10%-25% gradient) replaced the previously used acetonitrile (25%-75%) as the solvent, to reduce the carbon load into the plasma. In synthetic solutions, formation of thiomolybdates was found to occur spontaneously in the presence of excess sulfide and the degree of thiolation was highest at pH 7. Excess hydroxyl led to a transformation of thiomolybdates to molybdate. Under acidic to neutral conditions, precipitation of molybdenum and hydrolysis of tetrathiomolybdate were observed. Flash-freezing was found to be suitable to stabilize tetrathiomolybdate, with 2 mM) negatively affected the detection of molybdate, which eluted mainly in the dead volume, but had no negative effect on higher thiolated molybdates. Detection limits were ∼10 nM. With the newly developed IPC-ICP-MS method, thiomolybdates were found to form spontaneously in euxinic marine waters after adding a molybdate spike and occur naturally in sulfidic geothermal waters.

  5. Elemental speciation via high-performance liquid chromatography combined with inductively coupled plasma atomic emission spectroscopic detection: application of a direct injection nebulizer

    International Nuclear Information System (INIS)

    LaFreniere, K.E; Fassel, V.A.; Eckels, D.E.

    1987-01-01

    An evaluation is presented of a direct injection nebulizer (DIN) interfaced to a high-performance liquid chromatograph (HPLC) with inductively coupled plasma atomic emission spectroscopic (ICP-AES) detection for simultaneous multielement speciation. The limits of detection (LODs) obtained with the DIN interface in the HPLC mode were found to be comparable to those obtained by continuous-flow sample introduction into the ICP, or inferior by up to only a factor of 4. In addition, the DIN allowed for the direct injection into the ICP of a variety of common HPLC solvents (up to 100% methanol, acetonitrile, methyl isobutyl ketone, pyridine, and water). The HPLC-DIN-ICP-AES system was compared to other HPLC-atomic spectroscopic detection techniques and was found to offer substantial improvement over the alternative on-line, detection methods in terms of LODs. Representative applications of the HPLC-DIN-ICP-AES system to the elemental speciation of coal process streams, shale oil, solvent refined coal, and crude oil are presented

  6. Simultaneous determination of Cr(iii) and Cr(vi) using reversed-phased ion-pairing liquid chromatography with dynamic reaction cell inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Wolf, R.E.; Morrison, J.M.; Goldhaber, M.B.

    2007-01-01

    A method for the simultaneous determination of Cr(iii) and Cr(vi) species in waters, soil leachates and synthetic bio-fluids is described. The method uses reversed-phase ion-pairing liquid chromatography to separate the chromium species and a dynamic reaction cell (DRC??) equipped ICP-MS for detection of chromium. Separation of the chromium species is carried out in less than 2 min. Cr(iii) is complexed with ethylenediaminetetraacetic acid (EDTA) prior to separation by mixing samples with the mobile phase containing 2.0 mM tetrabutylammonium hydroxide (TBAOH), 0.5 mM EDTA (dipotassium salt), and 5% (vol/vol) methanol, adjusted to pH 7.6. The interfering 40Ar 12C+ background peak at mass 52 was reduced by over four orders of magnitude to less than 200 cps by using 0.65 mL min-1 ammonia as a reaction gas and an RPq setting on the DRC of 0.75. Method detection limits (MDLs) of 0.09 ??g L-1 for Cr(iii) and 0.06 ??g L-1 for Cr(vi) were obtained based on peak areas at mass 52 for 50 ??L injections of low level spikes. Reproducibility at 2 ??g L-1 was 3% RSD for 5 replicate injections. The tolerance of the method to various levels of common cations and anions found in natural waters and to matrix constituents found in soil leachates and simulated gastric and lung fluids was tested by performing spike recovery calculations for a variety of samples. ?? The Royal Society of Chemistry.

  7. Determination of trace amounts of rare-earth elements in highly pure neodymium oxide by sector field inductively coupled plasma mass spectrometry (ICP-SFMS) and high-performance liquid chromatography (HPLC) techniques

    Science.gov (United States)

    Pedreira, W. R.; Sarkis, J. E. S.; da Silva Queiroz, C. A.; Rodrigues, C.; Tomiyoshi, I. A.; Abrão, A.

    2003-02-01

    Recently rare-earth elements (REE) have received much attention in fields of geochemistry and industry. Rapid and accurate determinations of them are increasingly required as industrial demands expand. Sector field inductively coupled plasma mass spectrometry (ICP-SFMS) with high-performance liquid chromatography (HPLC) has been applied to the determination of REE. HR ICP-MS was used as an element-selective detector for HPLC in highly pure materials. The separation of REE with HPLC helped to avoid erroneous analytical results due to spectral interferences. Sixteen elements (Sc, Y and 14 lanthanides) were determined selectively with the HPLC/ICP-SFMS system using a concentration gradient methods. The detection limits with the HPLC/ICP-SFMS system were about 0.5-10 pg mL-1. The percentage recovery ranged from 90% to 100% for different REE. The %RSD of the methods varying between 2.5% and 4.5% for a set of five (n=5) replicates was found for the IPEN's material and for the certificate reference sample. Determination of trace REEs in two highly pure neodymium oxides samples (IPEN and Johnson Matthey Company) were performed. In short, the IPEN's materials which are highly pure (>99.9%) were successfully analyzed without spectral interferences.

  8. Analytical method for the determination of various arsenic species in rice, rice food products, apple juice, and other juices by ion chromatography-inductively coupled plasma/mass spectrometry.

    Science.gov (United States)

    Ellingson, David; Zywicki, Richard; Sullivan, Darryl

    2014-01-01

    Recent studies have shown that there are detectable levels of arsenic (As) in rice, rice food products, and apple juice. This has created significant concern to the public, the food industry, and various regulatory bodies. Classic test methods typically measure total As and are unable to differentiate the various As species. Since different As species have greatly different toxicities, an analytical method was needed to separate and quantify the different inorganic and organic species of As. The inorganic species arsenite [As(+3)] and arsenate [As(+5)] are highly toxic. With this in mind, an ion chromatography-inductively coupled plasma (IC-ICP/MS) method was developed and validated for rice and rice food products that can separate and individually measure multiple inorganic and organic species of As. This allows for the evaluation of the safety or risk associated with any product analyzed. The IC-ICP/MS method was validated on rice and rice food products, and it has been used successfully on apple juice. This paper provides details of the validated method as well as some lessons learned during its development. Precision and accuracy data are presented for rice, rice food products, and apple juice.

  9. Determination of trace amounts of rare-earth elements in highly pure neodymium oxide by sector field inductively coupled plasma mass spectrometry (ICP-SFMS) and high-performance liquid chromatography (HPLC) techniques

    International Nuclear Information System (INIS)

    Pedreira, W.R.; Sarkis, J.E.S.; Silva Queiroz, C.A. da; Rodrigues, C.; Tomiyoshi, I.A.; Abrao, A.

    2003-01-01

    Recently rare-earth elements (REE) have received much attention in fields of geochemistry and industry. Rapid and accurate determinations of them are increasingly required as industrial demands expand. Sector field inductively coupled plasma mass spectrometry (ICP-SFMS) with high-performance liquid chromatography (HPLC) has been applied to the determination of REE. HR ICP-MS was used as an element-selective detector for HPLC in highly pure materials. The separation of REE with HPLC helped to avoid erroneous analytical results due to spectral interferences. Sixteen elements (Sc, Y and 14 lanthanides) were determined selectively with the HPLC/ICP-SFMS system using a concentration gradient methods. The detection limits with the HPLC/ICP-SFMS system were about 0.5-10 pg mL -1 . The percentage recovery ranged from 90% to 100% for different REE. The %RSD of the methods varying between 2.5% and 4.5% for a set of five (n=5) replicates was found for the IPEN's material and for the certificate reference sample. Determination of trace REEs in two highly pure neodymium oxides samples (IPEN and Johnson Matthey Company) were performed. In short, the IPEN's materials which are highly pure (>99.9%) were successfully analyzed without spectral interferences

  10. Comparison of no gas and He/H2 cell modes used for reduction of isobaric interferences in selenium speciation by ion chromatography with inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Chen Zuliang; Wang Weihong; Mallavarapu, Megharaj; Naidu, Ravendra

    2008-01-01

    Inductively coupled plasma mass spectrometry (ICP-MS) used for the detection of most common selenium isotopes 78 Se (23.8%, abundance) and 80 Se (49.6%, abundance) is interfered in the presence of 38 Ar 40 Ar + and 40 Ar 40 Ar + in argon (Ar) gas. To address this issue, ICP-MS with an octopole reaction system (ORS) was explored for the detection of selenite and selenate, which was separated by anion-exchange chromatography. Results indicate that it was possible to detect 78 Se using no collusion gas, while to detect 80 Se a H 2 as the collusion/reaction gas was recommended since the background and noise were significantly reduced using H 2 as the gas. The selenium speciation interested was separated on a new column (G3154/101A, Agilent technologies) within 5 min using a mobile phase containing 10 mM NH 4 H 2 PO 4 and 20 mM NH 4 NO 3 at pH 6.5. Linear plots were obtained in a concentration range of 1-200 μg/L with detection limits less than of 0.4 μg/L for 80 Se (IV) and 0.6 μg/L for 80 Se (VI) using H 2 as the reaction gas. Finally, the proposed method was used in the determination of selenium in water and soil

  11. A simple method using on-line continuous leaching and ion exchange chromatography coupled to inductively coupled plasma mass spectrometry for the speciation analysis of bio-accessible arsenic in rice.

    Science.gov (United States)

    Horner, Nolan S; Beauchemin, Diane

    2012-03-02

    A simple method for the speciation analysis of bio-accessible arsenic (As) in rice was developed using a continuous on-line leaching method to release the bio-accessible fraction. The continuous on-line leaching method has several advantages over commonly used batch methods including quicker and easier sample preparation, reduced risk of contamination and access to real time leaching data. The bio-accessibility of As in the samples was monitored using inductively coupled plasma mass spectrometry (ICP-MS). Results from a certified reference material as well as cooked and uncooked white rice showed that the majority of As was leached by saliva. Results obtained using the continuous on-line leaching method were comparable to those obtained using a batch method. Speciation analysis of the saliva leachate was performed using ion exchange chromatography coupled to ICP-MS. The four most toxic forms of As (As(III), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA) and As(V)) were clearly separated within 5 min in a single chromatographic run. Over 92% of bio-accessible As in the certified reference material and uncooked white rice sample was in the form of DMA and As(V), whereas it was present as DMA and As(III) in the cooked white rice. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Methodology for monitoring gold nanoparticles and dissolved gold species in culture medium and cells used for nanotoxicity tests by liquid chromatography hyphenated to inductively coupled plasma-mass spectrometry.

    Science.gov (United States)

    López-Sanz, Sara; Fariñas, Nuria Rodríguez; Vargas, Rosario Serrano; Martín-Doimeadios, Rosa Del Carmen Rodríguez; Ríos, Ángel

    2017-03-01

    An analytical methodology based on coupling reversed-phase liquid chromatography (HPLC) to an inductively coupled plasma mass spectrometry (ICP-MS) has been developed for the characterization and identification of gold nanoparticles (AuNPs) and gold dissolved species (Au 3+ ) in culture medium (Dulbecco's Modified Eagle Medium, DMEM) and HeLa cells (a human cervical adenocarcinoma cell line) used in nanotoxicity tests. The influence of the culture medium was also studied and the method applied for nanotoxicity tests. It was also observed that AuNPs can undergo an oxidation process in the supernatants and only a small amount of AuNPs and dissolved Au 3+ was associated with cells. To evaluate the biological impact of AuNPs, a classical viability assay onto HeLa cells was performed using cellular media DMEM in the presence of increasing dosage of 10nm AuNPs. The results showed that 10nm AuNPs exhibit a slight toxic effect. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Qualitative and quantitative analysis of heparin and low molecular weight heparins using size exclusion chromatography with multiple angle laser scattering/refractive index and inductively coupled plasma/mass spectrometry detectors.

    Science.gov (United States)

    Ouyang, Yilan; Zeng, Yangyang; Yi, Lin; Tang, Hong; Li, Duxin; Linhardt, Robert J; Zhang, Zhenqing

    2017-11-03

    Heparin, a highly sulfated glycosaminoglycan, has been used as a clinical anticoagulant over 80 years. Low molecular weight heparins (LMWHs), heparins partially depolymerized using different processes, are widely used as clinical anticoagulants. Qualitative molecular weight (MW) and quantitative mass content analysis are two important factors that contribute to LMWH quality control. Size exclusion chromatography (SEC), relying on multiple angle laser scattering (MALS)/refractive index (RI) detectors, has been developed for accurate analysis of heparin MW in the absence of standards. However, the cations, which ion-pair with the anionic polysaccharide chains of heparin and LMWHs, had not been considered in previous reports. In this study, SEC with MALS/RI and inductively coupled plasma/mass spectrometry detectors were used in a comprehensive analytical approach taking both anionic polysaccharide and ion-paired cations heparin products. This approach was also applied to quantitative analysis of heparin and LMWHs. Full profiles of MWs and mass recoveries for three commercial heparin/LMWH products, heparin sodium, enoxaparin sodium and nadroparin calcium, were obtained and all showed higher MWs than previously reported. This important improvement more precisely characterized the MW properties of heparin/LMWHs and potentially many other anionic polysaccharides. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Effect of nebulizer/spray chamber interfaces on simultaneous, axial view inductively coupled plasma optical emission spectrometry for the direct determination of As and Se species separated by ion exchange high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Gettar, Raquel T.; Smichowski, Patricia; Garavaglia, Ricardo N.; Farias, Silvia; Batistoni, Daniel A.

    2005-01-01

    Different nebulizer/expansion chamber combinations were evaluated to assess their performance for sample introduction in the direct coupling with an axial view inductively coupled plasma multielement spectrometer for on-line determination of As and Se species previously separated by ion exchange-high performance liquid chromatography. The column effluents were injected into the plasma without prior derivatization. The instrument operation software was adapted for data acquisition and processing to allow multi-wavelength recording of the transient chromatographic peaks. After optimization of the chromatographic operating conditions, separation of mixtures of inorganic As and Se species, and of inorganic and two organic As species (monomethylarsonic and dimethylarsinic acids), was achieved with excellent resolution. Species discrimination from mixtures of As and Se oxyanions was further improved by the simultaneous element detection at specific analytical wavelengths. Three nebulizers and three spray chambers, employed in seven combinations, were tested as interfaces. Concentric nebulizers associated to a glass cyclonic chamber appear most suitable regarding sensitivity and signal to noise ratio. Measured element detection limits (3 σ) were around 10 ng ml -1 for all the species considered, making the method a viable alternative to similar procedures that employ volatile hydride generation previous to sample injection into the plasma. Analytical recoveries both for inorganic and organic species ranged between 92 and 107%. The method was demonstrated to be apt for the analysis of surface waters potentially subjected to natural contamination with arsenic

  15. Comparison of ultra-violet and inductively coupled plasma-atomic emission spectrometry for the on-line quantification of selenium species after their separation by reversed-phase liquid chromatography

    International Nuclear Information System (INIS)

    Tsopelas, Fotios N.; Ochsenkuehn-Petropoulou, Maria Th.; Mergias, Ioannis G.; Tsakanika, Lambrini V.

    2005-01-01

    An analytical approach for selenium speciation using liquid chromatography (LC) coupled with ultra-violet (UV) and inductively coupled plasma-atomic emission spectrometry (ICP-AES) was developed. The separation of the investigated selenium species, selenites, selenates, selenomethionine, selenocystine, selenocystamine and dimethyldiselenide was accomplished in less than 6 min on a BIO Wide Pore RP-18 column using sodium salt of n-octanesulfonic acid as ion-pairing modifier. The on-line detection of the separated selenium species was performed using UV spectrometry at the optimum wavelength of 192 nm, obtained by the UV spectra of the investigated individual selenium species. ICP-AES was also used as element specific on-line detector, after its coupling with the chromatographic system. The UV and ICP-AES detectors were compared for their suitability, including sensitivity and detection limits, for the on-line quantification of the six selenium species. The developed LC-UV as well as LC-ICP-AES techniques were successfully applied to a selenized yeast candidate reference material, after its enzymatic extraction with protease XIV. It was found that the described LC-UV technique is suitable for the determination of selenomethionine, the main selenium compound in the yeast, with an accuracy of 5%, although the UV detector is not element specific and it is rarely used for selenium speciation. This finding can prove valuable for routine laboratories to perform selenium speciation in such materials

  16. An Investigation on the Extraction and Quantitation of a Hexavalent Chromium in Acrylonitrile Butadiene Styrene Copolymer (ABS) and Printed Circuit Board (PCB) by Ion Chromatography Coupled with Inductively Coupled Plasma Atomic Emission Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Sang Ho; Kim, Yu Na [Mokpo National University, Muan (Korea, Republic of)

    2012-06-15

    A hexavalent chromium (Cr (VI)) is one of the hazardous substances regulated by the RoHS. The determination of Cr (VI) in various polymers and printed circuit board (PCB) has been very important. In this study, the three different analytical methods were investigated for the determination of a hexavalent chromium in Acrylonitrile Butadiene Styrene copolymer (ABS) and PCB. The results by three analytical methods were obtained and compared. An analytical method by UV-Visible spectrometer has been generally used for the determination of Cr (VI) in a sample, but a hexavalent chromium should complex with diphenylcarbazide for the detection in the method. The complexation did make an adverse effect on the quantitative analysis of Cr (VI) in ABS. The analytical method using diphenylcarbazide was also not applicable to printed circuit board (PCB) because PCB contained lots of irons. The irons interfered with the analysis of hexavalent chromium because those also could complex with diphenylcarbazide. In this study, hexavalent chromiums in PCB have been separated by ion chromatography (IC), then directly and selectively detected by inductively coupled plasma atomic emission spectrometry (ICP-AES). The quantity of Cr (VI) in PCB was 0.1 mg/kg

  17. Determination of trace elements in high pure rare earth oxide by double focusing inductively coupled plasma mass spectrometry (HR ICP-MS) and high performance liquid chromatography (HPLC) techniques

    International Nuclear Information System (INIS)

    Pedreira Filho, Walter dos Reis

    2000-01-01

    Rare earth oxides are used in several technological fields whose applications can be observed in several areas of modern technology, among which are included: lasers, semiconductors semi, high purity materials and metallic alloys. The field of applications of the rare earth elements is quite wide. Several important industrial applications are ceramics, catalysts and metallurgical as well as research areas and high technology sectors. Such applications have been presenting an accentuated growth in the last years. Chemical characterization of rare earth oxides of high purity has been constituting one of the major challenges of analytical chemistry. Several analytical techniques were used for chemical characterization of high purity rare earth the oxides. Even so, those techniques present limitations when one needs to characterize materials of a high level of purity, as in the case of rare earth oxides. Some of those limitations are associated, for example, to spectral interference. Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is a powerful analytical tool for quantitative analysis of metal impurities in high purity materials. The Instituto de Pesquisas Energeticas e Nucleares (IPEN) has an unit of production and purification of rare earth oxides, with above 99,9% level of purity. In this work, the rare earth impurities were characterized in samples (La 2 O 3 ; CeO 2 ; Pr 6 O 11 ; Nd 2 O 3 ; Sm 2 O 3 ; Gd 2 O 3 ; Y 2 O 3 ) produced at the IPEN and certified standard materials produced by Johnson Matthey Chemical (JMC). The technique of high performance liquid chromatography (HPLC) was used in the separation of the impurities. Quantification of metallic impurities was carried out as inductively coupled plasma mass spectrometer (HR-ICP MS). In this work it is presented a new analytical methodology in the chemical characterization of metallic impurities in rare earth oxides of high purity (> 99,9%) with and without separation of the matrix. Analyses of standard

  18. Multilaboratory Validation of First Action Method 2016.04 for Determination of Four Arsenic Species in Fruit Juice by High-Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometry.

    Science.gov (United States)

    Kubachka, Kevin; Heitkemper, Douglas T; Conklin, Sean

    2017-07-01

    Before being designated AOAC First Action Official MethodSM 2016.04, the U.S. Food and Drug Administration's method, EAM 4.10 High Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometric Determination of Four Arsenic Species in Fruit Juice, underwent both a single-laboratory validation and a multilaboratory validation (MLV) study. Three federal and five state regulatory laboratories participated in the MLV study, which is the primary focus of this manuscript. The method was validated for inorganic arsenic (iAs) measured as the sum of the two iAs species arsenite [As(III)] and arsenate [As(V)], dimethylarsinic acid (DMA), and monomethylarsonic acid (MMA) by analyses of 13 juice samples, including three apple juice, three apple juice concentrate, four grape juice, and three pear juice samples. In addition, two water Standard Reference Materials (SRMs) were analyzed. The method LODs and LOQs obtained among the eight laboratories were approximately 0.3 and 2 ng/g, respectively, for each of the analytes and were adequate for the intended purpose of the method. Each laboratory analyzed method blanks, fortified method blanks, reference materials, triplicate portions of each juice sample, and duplicate fortified juice samples (one for each matrix type) at three fortification levels. In general, repeatability and reproducibility of the method was ≤15% RSD for each species present at a concentration >LOQ. The average recovery of fortified analytes for all laboratories ranged from 98 to 104% iAs, DMA, and MMA for all four juice sample matrixes. The average iAs results for SRMs 1640a and 1643e agreed within the range of 96-98% of certified values for total arsenic.

  19. Selenium speciation in radix puerariae using ultrasonic assisted extraction combined with reversed phase high performance liquid chromatography-inductively coupled plasma-mass spectrometry after magnetic solid-phase extraction with 5-sulfosalicylic acid functionalized magnetic nanoparticles

    Science.gov (United States)

    Cao, Yupin; Yan, Lizhen; Huang, Hongli; Deng, Biyang

    2016-08-01

    A new method for determination of selenium species in radix puerariae was described. The method consists of sample enrichment with 5-sulfosalicylic acid (SSA)-functionalized silica-coated magnetic nanoparticles (SMNPs), high performance liquid chromatography (HPLC) separation, and online detection using inductively coupled plasma mass spectrometry (ICP-MS). The selenium species were extracted using ultrasonic extraction system with a mixture of protease K and lipase. The SSA-SMNPs were used to enrich trace amounts of selenite [Se(IV)], selenate [Se(VI)], selenomethionine (SeMet), and selenocystine (SeCys2) from lower selenium containing samples. Under the optimal conditions, the limits of detection (3σ) for SeCys2, Se(IV), SeMet and Se(VI) were observed as 0.0023, 0.0015, 0.0043, and 0.0016 ng mL- 1, respectively. The RSD values (n = 6) of method for intraday were observed between 0.5% and 0.9%. The RSD values of method for interday were less than 1.3%. The linear concentration ranges for SeCys2, Se(IV), SeMet and Se(VI) were 0.008-1000, 0.005-200, 0.015-500 and 0.006-200 ng mL- 1, respectively. The detection limits of this method were improved by 10 times due to the enrichment with the SSA-SMNP extraction. The contents of SeCys2, Se(IV), SeMet, and Se(VI) in radix puerariae were determined as 0.0140, 0.171, 0.0178, and 0.0344 μg g- 1, respectively. The recoveries were in the range of 95.6%-99.4% and the RSDs (n = 6) of recoveries were less than 1.5%.

  20. Speciation of Bio-Available Iodine in Abalone (Haliotis discus hannai) by High-Performance Liquid Chromatography Hyphenated with Inductively Coupled Plasma-Mass Spectrometry Using an In Vitro Method.

    Science.gov (United States)

    Doh, Han Sol; Park, Hyun Jin

    2018-06-01

    Abalone is one of the most valuable marine products found in East Asia because it is rich in nutritious substances including iodine. In this study, the in vitro dialyzability approach was used to assess the bio-available iodine species in abalone. Iodide, iodate, 3-iodo-L-tyrosine (MIT), and 3,5-diiodo-L-tyrosine (DIT) were separated by high-performance liquid chromatography hyphenated with inductively coupled plasma-mass spectrometry (HPLC-ICP-MS). To assure the consistency, reliability, and accuracy of the data, the method was validated. Comparison of the total iodine in abalone muscle and viscera indicated that abalone muscle showed greater digestion/absorption efficiency than abalone viscera (digestion efficiency: 68.13 ± 2.59% and 47.88 ± 5.76% and absorption efficiency: 59.78 ± 2.93% and 35.12 ± 1.43% for abalone viscera and muscle, respectively). However, evaluation of the sum of the analyzed iodine species targeted in this study by HPLC-ICP-MS indicated that abalone muscle showed lower digestion efficiency and similar absorption efficiency compared to that of abalone viscera (digestion efficiency: 35.52 ± 5.41% and 28.84 ± 1.83%; absorption efficiency: 23.56 ± 4.38% and 27.56 ± 1.51% for abalone viscera and muscle, respectively). The main forms of iodine detected in abalone muscle were iodide and MIT, whereas iodide was the major form in abalone viscera. The bio-available iodine in abalone was quantified via an in vitro method employing HPLC-ICP-MS. The results of this study indicated that abalone is feasible as a new iodine source and may prospectively find application in iodine-fortified foods. © 2018 Institute of Food Technologists®.

  1. Investigation into the determination of trimethylarsine in natural gas and its partitioning into gas and condensate phases using (cryotrapping)/gas chromatography coupled to inductively coupled plasma mass spectrometry and liquid/solid sorption techniques

    International Nuclear Information System (INIS)

    Krupp, E.M.; Johnson, C.; Rechsteiner, C.; Moir, M.; Leong, D.; Feldmann, J.

    2007-01-01

    Speciation of trialkylated arsenic compunds in natural gas, pressurized and stable condensate samples from the same gas well was performed using (Cryotrapping) Gas Chromatography-Inductively Coupled Plasma Mass Spectrometry. The major species in all phases investigated was found to be trimethylarsine with a highest concentration of 17.8 ng/L (As) in the gas phase and 33.2 μg/L (As) in the stable condensate phase. The highest amount of trimethylarsine (121 μg/L (As)) was found in the pressurized condensate, along with trace amounts of non-identified higher alkylated arsines. Volatile arsenic species in natural gas and its related products cause concern with regards to environment, safety, occupational health and gas processing. Therefore, interest lies in a fast and simple field method for the determination of volatile arsenicals. Here, we use simple liquid and solid sorption techniques, namely absorption in silver nitrate solution and adsorption on silver nitrate impregnated silica gel tubes followed by total arsenic determination as a promising tool for field monitoring of volatile arsenicals in natural gas and gas condensates. Preliminary results obtained for the sorption-based methods show that around 70% of the arsenic is determined with these methods in comparison to volatile arsenic determination using GC-ICP-MS. Furthermore, an inter-laboratory- and inter-method comparison was performed using silver nitrate impregnated silica tubes on 14 different gas samples with concentrations varying from below 1 to 1000 μg As/m 3 natural gas. The results obtained from the two laboratories differ in a range of 10 to 60%, but agree within the order of magnitude, which is satisfactory for our purposes

  2. Cytosolic distributions of highly toxic metals Cd and Tl and several essential elements in the liver of brown trout (Salmo trutta L.) analyzed by size exclusion chromatography and inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Dragun, Zrinka; Krasnići, Nesrete; Kolar, Nicol; Filipović Marijić, Vlatka; Ivanković, Dušica; Erk, Marijana

    2018-05-15

    Cytosolic distributions of nonessential metals Cd and Tl and seven essential elements among compounds of different molecular masses were studied in the liver of brown trout (Salmo trutta) from the karstic Krka River in Croatia. Analyses were done by size exclusion high performance liquid chromatography and high resolution inductively coupled plasma mass spectrometry. Common feature of Cd and Tl, as highly toxic elements, was their distribution within only two narrow peaks. The increase of cytosolic Cd concentrations was reflected in marked increase of Cd elution within low molecular mass peak (maximum at ∼15 kDa), presumably containing metallothioneins (MTs), which indicated successful Cd detoxification in brown trout liver under studied exposure conditions. Contrary, the increase of cytosolic Tl concentrations was reflected in marked increase of Tl elution within high molecular mass peak (maximum at 140 kDa), which probably indicated incomplete Tl detoxification. Common feature of the majority of studied essential elements was their distribution within more peaks, often broad and not well resolved, which is consistent with their numerous physiological functions. Among observed associations of essential metals/nonmetal to proteins, the following could be singled out: Cu and Zn association to MTs, Fe association to storage protein ferritin, and Se association to compounds of very low molecular masses (<5 kDa). The obtained results present the first step towards identification of metal-binding compounds in hepatic cytosol of brown trout, and thus a significant contribution to better understanding of metal fate in the liver of that important bioindicator species. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Plasma chromatography

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    This book examines the fundamental theory and various applications of ion mobility spectroscopy. Plasma chromatography developed from research on the diffusion and mobility of ions. Topics considered include instrument design and description (e.g., performance, spectral interpretation, sample handling, mass spectrometry), the role of ion mobility in plasma chromatography (e.g., kinetic theory of ion transport), atmospheric pressure ionization (e.g., rate equations), the characterization of isomers by plasma chromatography (e.g., molecular ion characteristics, polynuclear aromatics), plasma chromatography as a gas chromatographic detection method (e.g., qualitative analysis, continuous mobility monitoring, quantitative analysis), the analysis of toxic vapors by plasma chromatography (e.g., plasma chromatograph calibration, instrument control and data processing), the analysis of semiconductor devices and microelectronic packages by plasma chromatography/mass spectroscopy (e.g., analysis of organic surface contaminants, analysis of water in sealed electronic packages), and instrument design and automation (hardware, software)

  4. Hydroxylapatite chromatography.

    Science.gov (United States)

    Broadhurst, A V

    2001-05-01

    Hydroxylapatite (also called hydroxyapatite), a form of calcium phosphate, can be used as a matrix for the chromatography of both proteins and nucleic acids. Protocols are provided for both standard low-pressure chromatography of a protein mixture using a hydroxylapatite column prepared in the laboratory, and an HPLC method, applicable to proteins and nucleic acids, that uses a commercially available column. Alternate protocols describe column chromatography using a step gradient or batch binding and step-gradient elution.

  5. Chromium Speciation Analysis by Ion Chromatography Coupled ...

    African Journals Online (AJOL)

    Two methods coupling ion chromatography with inductively coupled plasma - optical emission spectroscopy (ICP-OES) were developed for the simultaneous separation and determination of Cr(III) and Cr(VI) species. In the first method, anion chromatography with sodium bicarbonate/carbonate solution as the eluent was ...

  6. Labor Induction

    Science.gov (United States)

    f AQ FREQUENTLY ASKED QUESTIONS FAQ154 LABOR, DELIVERY, AND POSTPARTUM CARE Labor Induction • What is labor induction? • Why is labor induced? • What is the Bishop score? • What is “ripening ...

  7. Determination of methylmercury and estimation of total mercury in seafood using high performance liquid chromatography (HPLC) and inductively coupled plasma-mass spectrometry (ICP-MS): Method development and validation

    Energy Technology Data Exchange (ETDEWEB)

    Hight, Susan C. [Elemental Research Branch, Center for Food Safety and Applied Nutrition, US Food and Drug Administration, 5100 Paint Branch Parkway, College Park, MD 20740-3835 (United States)]. E-mail: susan.hight@fda.gov; Cheng, John [Elemental Research Branch, Center for Food Safety and Applied Nutrition, US Food and Drug Administration, 5100 Paint Branch Parkway, College Park, MD 20740-3835 (United States)]. E-mail: john.cheng@fda.gov

    2006-05-17

    A method was developed for determination of methylmercury and estimation of total mercury in seafood. Mercury (Hg) compounds were extracted from 0.5 g edible seafood or 0.2 g lyophilized reference material by adding 50 ml aqueous 1% w/v L-cysteine.HCl.H{sub 2}O and heating 120 min at 60 deg. C in glass vials. Hg compounds in 50 {mu}l of filtered extract were separated by reversed-phase high performance liquid chromatography using a C-18 column and aqueous 0.1% w/v L-cysteine.HCl.H{sub 2}O + 0.1% w/v L-cysteine mobile phase at room temperature and were detected by inductively coupled plasma-mass spectrometry at mass-to-charge ratio 202. Total Hg was calculated as the mathematical sum of methyl and inorganic Hg determined in extracts. For seafoods containing 0.055-2.78 mg kg{sup -1} methylmercury and 0.014-0.137 mg kg{sup -1} inorganic Hg, precision of analyses was {<=}5% relative standard deviation (R.S.D.) for methylmercury and {<=}9% R.S.D. for inorganic Hg. Recovery of added analyte was 94% for methylmercury and 98% for inorganic Hg. Methyl and total Hg results for reference materials agreed with certified values. Limits of quantitation were 0.007 mg kg{sup -1} methylmercury and 0.005 mg kg{sup -1} inorganic Hg in edible seafood and 0.017 mg kg{sup -1} methylmercury and 0.012 mg kg{sup -1} inorganic Hg in lyophilized reference materials. Evaluation of analyte stability demonstrated that L-cysteine both stabilized and de-alkylated methylmercury, depending on holding time and cysteine concentration. Polypropylene adversely affected methylmercury stability. Total Hg results determined by this method were equivalent to results determined independently by cold vapour-atomic absorption spectrometry. Methylmercury was the predominant form of Hg in finfish. Ratios of methylmercury/total Hg determined by this method were 93-98% for finfish and 38-48% for mollusks.

  8. Induction linacs

    International Nuclear Information System (INIS)

    Keefe, D.

    1986-07-01

    The principle of linear induction acceleration is described, and examples are given of practical configurations for induction linacs. These examples include the Advanced Technology Accelerator, Long Pulse Induction Linac, Radial Line Accelerator (RADLAC), and Magnetically-Insulated Electron-Focussed Ion Linac. A related concept, the auto accelerator, is described in which the high-current electron-beam technology in the sub-10 MeV region is exploited to produce electron beams at energies perhaps as high as the 100 to 1000 MeV range. Induction linacs for ions are also discussed. The efficiency of induction linear acceleration is analyzed

  9. Inductive reasoning.

    Science.gov (United States)

    Hayes, Brett K; Heit, Evan; Swendsen, Haruka

    2010-03-01

    Inductive reasoning entails using existing knowledge or observations to make predictions about novel cases. We review recent findings in research on category-based induction as well as theoretical models of these results, including similarity-based models, connectionist networks, an account based on relevance theory, Bayesian models, and other mathematical models. A number of touchstone empirical phenomena that involve taxonomic similarity are described. We also examine phenomena involving more complex background knowledge about premises and conclusions of inductive arguments and the properties referenced. Earlier models are shown to give a good account of similarity-based phenomena but not knowledge-based phenomena. Recent models that aim to account for both similarity-based and knowledge-based phenomena are reviewed and evaluated. Among the most important new directions in induction research are a focus on induction with uncertain premise categories, the modeling of the relationship between inductive and deductive reasoning, and examination of the neural substrates of induction. A common theme in both the well-established and emerging lines of induction research is the need to develop well-articulated and empirically testable formal models of induction. Copyright © 2010 John Wiley & Sons, Ltd. For further resources related to this article, please visit the WIREs website. Copyright © 2010 John Wiley & Sons, Ltd.

  10. Teacher induction

    NARCIS (Netherlands)

    Beijaard, D.; Buitink, J.; Kessels, C.; Peterson, P.; Baker, E.; McGraw, B.

    2010-01-01

    Teacher induction programs are intended to support the professional development of beginning teachers and thereby contribute to the reduction of teacher attrition during the early teaching years. Teacher induction programs are often based upon a deficit model with a focus on the better organization

  11. Practicing induction:

    DEFF Research Database (Denmark)

    Sprogøe, Jonas; Rohde, Nicolas

    2009-01-01

    We claim that induction potentially triggers both individual and organizational learning and by drawing on practice-based theory we discuss how the interplay between individual and organization, what we call a generative dance, ignites both kinds of learning.......We claim that induction potentially triggers both individual and organizational learning and by drawing on practice-based theory we discuss how the interplay between individual and organization, what we call a generative dance, ignites both kinds of learning....

  12. Validation of methodologies for the analysis of lead and methyl-ether in gasoline, using the techniques of atomic emission with plasma source coupled inductively and micellar liquid chromatography

    International Nuclear Information System (INIS)

    Redondo Escalante, M.

    1995-01-01

    This study established and optimized the experimental variables for the lead quantization through the Icp-Aes technique, in aqueous media. A comparative study of several proposal methods, that appears in the literature for the extraction in aqueous media of the lead in gasoline was made. It determined that it is not possible, to make this procedure using the reaction of hydrolysis of tetraethyl lead. The op tim conditions were established, for the lead quantization in gasoline, using methyl-isobutyl-ketone and also ethanol as dis solvents. The conditions of the proposed methodologies were optimized, and the variables of analytical performance were defined. It was demonstrated, that it is possible to prepare lead dissolution patterns, in organic media, starting from inorganic salts of this metal. The techniques of chromatography of gases and of liquid chromatography of high pressure, in the analysis of methyl-ter butyl-ether (Mtbe), were compared. It demonstrated that it is possible, to quantize the Mtbe through the HPLC technique, and it found that the 'micellar' liquid chromatography. (author) [es

  13. Gas chromatography

    International Nuclear Information System (INIS)

    Cram, S.P.; Risby, T.H.; Field, L.R.; Yu, W.L.

    1980-01-01

    In addition to the published literature for the years 1978 - 79, this review of developments in the field of gas chromatography includes earlier articles of particular significance appearing in foreign journals and the patent literature which was not available at the time of the previous review. The articles cited were selected as presenting the most fundamental developments in theory, methodology, and instrumentation. Some applications are cited if they reflect an advance in the state-of-the-art or have particular relevance to new developments. 1149 references are cited

  14. Induction practice -

    DEFF Research Database (Denmark)

    Rohde, Nicolas; Sprogøe, Jonas

    2007-01-01

    that induction potentially triggers both individual and organizational learning and by drawing on practice-based theory we discuss how the interplay between individual and the organization, what we call agenerative dance, ignites both kinds of learning. We focus on and describe the interplay , ignites both kinds...

  15. Determination of aminopolycarboxylic acids at ultra-trace levels by means of online coupling ion exchange chromatography and inductively coupled plasma-mass spectrometry with indirect detection via their Pd2+-complexes

    International Nuclear Information System (INIS)

    Nette, David; Seubert, Andreas

    2015-01-01

    Highlights: • 8 important APCA’s analyzed in one run instead of 3 in the previous method. • Pd 2+ extents the methods applicability to 3 and more dentate amino carboxylic acids. • Separation system optimized for the isocratic determination of important APCA’s. • Thermodynamic stability of APCA–Pd 2+ complexes is higher than for Fe 3+ and In 3+ . • Pd 2+ is kinetically much slower than Fe 3+ and In 3+ and makes the method more rugged. - Abstract: A new indirect IC-ICP-MS method for the determination of aminopolycarboxylic acids in water samples is described. It is based on the addition of an excess of Pd(II) to water samples. The analytes are forced into very strong and negatively charged palladium complexes, separated by ion exchange chromatography and detected by their palladium content, utilizing an on-line coupled ICP-MS. This method is suitable to determine the concentration of 8 aminopolycarboxylic acids (nitrilotriacetic acid (NTA), (2-carboxyethyl) iminodiacetic acid (β-ADA), methylglycinediacetic acid (MGDA), 2-hydroxyethyl) ethylenediamine triacetic acid (HEDTA), diethylene triamine pentaacetic acid (DTPA), ethylendiamine tetraacetic acid (EDTA), 1,3-diaminopropane tetraacetic acid (1,3-PDTA) and 1,2-diaminopropane tetraacetic acid (1,2-PDTA) at the ng kg −1 level. The method is faster and easier than the established gas chromatography (GC)-method ISO 16588:2002 [1] and up to two orders of magnitude more sensitive than the ion pair chromatography based method of DIN 38413-8. Analytic performance is superior to ISO 16588:2002 and the comparability is good

  16. Determination of aminopolycarboxylic acids at ultra-trace levels by means of online coupling ion exchange chromatography and inductively coupled plasma-mass spectrometry with indirect detection via their Pd{sup 2+}-complexes

    Energy Technology Data Exchange (ETDEWEB)

    Nette, David; Seubert, Andreas, E-mail: seubert@staff.uni-marburg.de

    2015-07-16

    Highlights: • 8 important APCA’s analyzed in one run instead of 3 in the previous method. • Pd{sup 2+} extents the methods applicability to 3 and more dentate amino carboxylic acids. • Separation system optimized for the isocratic determination of important APCA’s. • Thermodynamic stability of APCA–Pd{sup 2+} complexes is higher than for Fe{sup 3+} and In{sup 3+}. • Pd{sup 2+} is kinetically much slower than Fe{sup 3+} and In{sup 3+} and makes the method more rugged. - Abstract: A new indirect IC-ICP-MS method for the determination of aminopolycarboxylic acids in water samples is described. It is based on the addition of an excess of Pd(II) to water samples. The analytes are forced into very strong and negatively charged palladium complexes, separated by ion exchange chromatography and detected by their palladium content, utilizing an on-line coupled ICP-MS. This method is suitable to determine the concentration of 8 aminopolycarboxylic acids (nitrilotriacetic acid (NTA), (2-carboxyethyl) iminodiacetic acid (β-ADA), methylglycinediacetic acid (MGDA), 2-hydroxyethyl) ethylenediamine triacetic acid (HEDTA), diethylene triamine pentaacetic acid (DTPA), ethylendiamine tetraacetic acid (EDTA), 1,3-diaminopropane tetraacetic acid (1,3-PDTA) and 1,2-diaminopropane tetraacetic acid (1,2-PDTA) at the ng kg{sup −1} level. The method is faster and easier than the established gas chromatography (GC)-method ISO 16588:2002 [1] and up to two orders of magnitude more sensitive than the ion pair chromatography based method of DIN 38413-8. Analytic performance is superior to ISO 16588:2002 and the comparability is good.

  17. High-performance liquid chromatography and inductively coupled plasma mass spectrometry (HPLC-ICP-MS) for the analysis of xenobiotic metabolites in rat urine: application to the metabolites of 4-bromoaniline.

    Science.gov (United States)

    Nicholson, J K; Lindon, J C; Scarfe, G; Wilson, I D; Abou-Shakra, F; Castro-Perez, J; Eaton, A; Preece, S

    2000-02-01

    The use of HPLC-ICP-MS for the profiling and quantification of the metabolites of 4-bromoaniline following reversed-phase gradient chromatography is demonstrated. In the 0-8 h post dose sample, which contained the highest concentrations of compound-related material, it was possible to detect at least 16 metabolites of the compound. The methodology described offers the possibility of obtaining metabolite profiles and quantification for drugs and other xenobiotics in biological fluids and excreta without the requirement for radiolabelled tracers.

  18. A field survey of metal binding to metallothionein and other cytosolic ligands in liver of eels using an on-line isotope dilution method in combination with size exclusion (SE) high pressure liquid chromatography (HPLC) coupled to Inductively Coupled Plasma time-of-flight Mass Spectrometry (ICP-TOFMS).

    Science.gov (United States)

    Van Campenhout, Karen; Goenaga Infante, Heidi; Goemans, Geert; Belpaire, Claude; Adams, Freddy; Blust, Ronny; Bervoets, Lieven

    2008-05-15

    The effect of metal exposure on the accumulation and cytosolic speciation of metals in livers of wild populations of European eel with special emphasis on metallothioneins (MT) was studied. Four sampling sites in Flanders showing different degrees of heavy metal contamination were selected for this purpose. An on-line isotope dilution method in combination with size exclusion (SE) high pressure liquid chromatography (HPLC) coupled to Inductively Coupled Plasma time-of-flight Mass Spectrometry (ICP-TOFMS) was used to study the cytosolic speciation of the metals. The distribution of the metals Cd, Cu, Ni, Pb and Zn among cytosolic fractions displayed strong differences. The cytosolic concentration of Cd, Ni and Pb increased proportionally with the total liver levels. However, the cytosolic concentrations of Cu and Zn only increased above a certain liver tissue threshold level. Cd, Cu and Zn, but not Pb and Ni, were largely associated with the MT pool in correspondence with the environmental exposure and liver tissue concentrations. Most of the Pb and Ni and a considerable fraction of Cu and Zn, but not Cd, were associated to High Molecular Weight (HMW) fractions. The relative importance of the Cu and Zn in the HMW fraction decreased with increasing contamination levels while the MT pool became progressively more important. The close relationship between the cytosolic metal load and the total MT levels or the metals bound on the MT pool indicates that the metals, rather than other stress factors, are the major factor determining MT induction.

  19. Induction Brazing

    DEFF Research Database (Denmark)

    Henningsen, Poul

    , or if the hottest area is located outside the joint interface, a number of defects may appear: the braze metal may flow away from the joint, the flux may burn off, poor binding of the braze metal may appear or the braze metal may be overheated. Joint geometry as well as electro-magnetic properties of the work piece...... presents a combined numerical and experimental method for determination of appropriate/optimiged coil geometry and position in induction brazing tube-to-plate joints of different ratios between tube and plate thickness and different combinations of the materials stainless steel, brass and copper....... The method has proven to give successful results in brazing tube-plate joints of copper-brass, copper-stainless steel, stainless steel-brass, and stainless steel-stainless steel. A new design of an adjustable flux concentrator for induction heating tube-to-plate joints is proposed and tested on a variety...

  20. Cromatografia unificada Unified chromatography

    Directory of Open Access Journals (Sweden)

    Carin von Mühlen

    2004-10-01

    Full Text Available The scope of this study encompasses an overview of the principles of unified chromatography as well as the principles of chromatographic techniques as applied to unified systems, which include gas chromatography, liquid chromatography, supercritical fluid chromatography, high temperature and high pressure liquid chromatography, micro-liquid chromatography, enhanced fluidity chromatography, and solvating gas chromatography. Theoretical considerations and individual instrumental parameters such as mobile phase, sample introduction system, columns, and detection system are also discussed. Future applications of this separation approach are discussed.

  1. Cobalamin Concentrations in Fetal Liver Show Gender Differences: A Result from Using a High-Pressure Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry as an Ultratrace Cobalt Speciation Method.

    Science.gov (United States)

    Bosle, Janine; Goetz, Sven; Raab, Andrea; Krupp, Eva M; Scheckel, Kirk G; Lombi, Enzo; Meharg, Andrew A; Fowler, Paul A; Feldmann, Jörg

    2016-12-20

    Maternal diet and lifestyle choices may affect placental transfer of cobalamin (Cbl) to the fetus. Fetal liver concentration of Cbl reflects nutritional status with regards to vitamin B12, but at these low concentration current Cbl measurement methods lack robustness. An analytical method based on enzymatic extraction with subsequent reversed-phase-high-pressure liquid chromatography (RP-HPLC) separation and parallel ICPMS and electrospray ionization (ESI)-Orbitrap-MS to determine specifically Cbl species in liver samples of only 10-50 mg was developed using 14 pig livers. Subsequently 55 human fetal livers were analyzed. HPLC-ICPMS analysis for cobalt (Co) and Cbl gave detection limits of 0.18 ng/g and 0.88 ng/g d.m. in liver samples, respectively, with a recovery of >95%. Total Co (Co t ) concentration did not reflect the amount of Cbl or vitamin B12 in the liver. Cbl bound Co contributes only 45 ± 15% to Co t . XRF mapping and μXANES analysis confirmed the occurrence of non-Cbl cobalt in pig liver hot spots indicating particular Co. No correlations of total cobalt nor Cbl with fetal weight or weeks of gestation were found for the human fetal livers. Although no gender difference could be identified for total Co concentration, female livers were significantly higher in Cbl concentration (24.1 ± 7.8 ng/g) than those from male fetuses (19.8 ± 7.1 ng/g) (p = 0.04). This HPLC-ICPMS method was able to quantify total Co t and Cbl in fetus liver, and it was sensitive and precise enough to identify this gender difference.

  2. Report: Affinity Chromatography.

    Science.gov (United States)

    Walters, Rodney R.

    1985-01-01

    Supports, affinity ligands, immobilization, elution methods, and a number of applications are among the topics considered in this discussion of affinity chromatography. An outline of the basic principles of affinity chromatography is included. (JN)

  3. Chromatography resin support

    Science.gov (United States)

    Dobos, James G.

    2002-01-01

    An apparatus and method of using an improved chromatography resin support is disclosed. The chromatography support platform is provided by a stainless steel hollow cylinder adapted for being inserted into a chromatography column. An exterior wall of the stainless steel cylinder defines a groove for carrying therein an "O"-ring. The upper surface of the stainless steel column is covered by a fine stainless steel mesh welded to the edges of the stainless steel cylinder. When placed upon a receiving ledge defined within a chromatography column, the "O"-ring provides a fluid tight seal with the inner edge wall of the chromatography cylinder. The stainless steel mesh supports the chromatography matrix and provides a back flushable support which is economical and simple to construct.

  4. Separation techniques: Chromatography

    Science.gov (United States)

    Coskun, Ozlem

    2016-01-01

    Chromatography is an important biophysical technique that enables the separation, identification, and purification of the components of a mixture for qualitative and quantitative analysis. Proteins can be purified based on characteristics such as size and shape, total charge, hydrophobic groups present on the surface, and binding capacity with the stationary phase. Four separation techniques based on molecular characteristics and interaction type use mechanisms of ion exchange, surface adsorption, partition, and size exclusion. Other chromatography techniques are based on the stationary bed, including column, thin layer, and paper chromatography. Column chromatography is one of the most common methods of protein purification. PMID:28058406

  5. Chromatography of phosphorus oxoacids

    International Nuclear Information System (INIS)

    Ohashi, S.

    1975-01-01

    The present state of studies on the chromatographic separation of phosphorus oxoacids is surveyed. In this paper, chromatographic techniques are divided into four groups, i.e. paper and thin-layer chromatography, paper electrophoresis, ion-exchange chromatography, and gel chromatography. The separation mechanisms and characteristics for these chromatographic methods are discussed and some examples for the separation of phosphorus oxoacids are described. As examples of the application of ion-exchange and gel chromatography, studies on the hot atom chemistry of 32 P in solid inorganic phosphates and those on the substitution reactions between diphosphonate (diphosphite) and polyphosphates are reported. (author)

  6. Inductive Monitoring System (IMS)

    Data.gov (United States)

    National Aeronautics and Space Administration — IMS: Inductive Monitoring System The Inductive Monitoring System (IMS) is a tool that uses a data mining technique called clustering to extract models of normal...

  7. Liquid Chromatography in 1982.

    Science.gov (United States)

    Freeman, David H.

    1982-01-01

    Reviews trends in liquid chromatography including apparatus, factors affecting efficient separation of a mixture (peak sharpness and speed), simplified problem-solving, adsorption, bonded phase chromatography, ion selectivity, and size exclusion. The current trend is to control chemical selectivity by the liquid phase. (Author/JN)

  8. Column Liquid Chromatography.

    Science.gov (United States)

    Majors, Ronald E.; And Others

    1984-01-01

    Reviews literature covering developments of column liquid chromatography during 1982-83. Areas considered include: books and reviews; general theory; columns; instrumentation; detectors; automation and data handling; multidimensional chromatographic and column switching techniques; liquid-solid chromatography; normal bonded-phase, reversed-phase,…

  9. Inductive Reasoning and Writing

    Science.gov (United States)

    Rooks, Clay; Boyd, Robert

    2003-01-01

    Induction, properly understood, is not merely a game, nor is it a gimmick, nor is it an artificial way of explaining an element of reasoning. Proper understanding of inductive reasoning--and the various types of reasoning that the authors term inductive--enables the student to evaluate critically other people's writing and enhances the composition…

  10. Induction machine handbook

    CERN Document Server

    Boldea, Ion

    2002-01-01

    Often called the workhorse of industry, the advent of power electronics and advances in digital control are transforming the induction motor into the racehorse of industrial motion control. Now, the classic texts on induction machines are nearly three decades old, while more recent books on electric motors lack the necessary depth and detail on induction machines.The Induction Machine Handbook fills industry's long-standing need for a comprehensive treatise embracing the many intricate facets of induction machine analysis and design. Moving gradually from simple to complex and from standard to

  11. Gas chromatography in space

    Science.gov (United States)

    Akapo, S. O.; Dimandja, J. M.; Kojiro, D. R.; Valentin, J. R.; Carle, G. C.

    1999-01-01

    Gas chromatography has proven to be a very useful analytical technique for in situ analysis of extraterrestrial environments as demonstrated by its successful operation on spacecraft missions to Mars and Venus. The technique is also one of the six scientific instruments aboard the Huygens probe to explore Titan's atmosphere and surface. A review of gas chromatography in previous space missions and some recent developments in the current environment of fiscal constraints and payload size limitations are presented.

  12. Supercritical fluid chromatography

    Science.gov (United States)

    Vigdergauz, M. S.; Lobachev, A. L.; Lobacheva, I. V.; Platonov, I. A.

    1992-03-01

    The characteristic features of supercritical fluid chromatography (SCFC) are examined and there is a brief historical note concerning the development of the method. Information concerning the use of supercritical fluid chromatography in the analysis of objects of different nature is presented in the form of a table. The roles of the mobile and stationary phases in the separation process and the characteristic features of the apparatus and of the use of the method in physicochemical research are discussed. The bibliography includes 364 references.

  13. Urofollitropin and ovulation induction

    NARCIS (Netherlands)

    van Wely, Madelon; Yding Andersen, Claus; Bayram, Neriman; van der Veen, Fulco

    2005-01-01

    Anovulation is a common cause of female infertility. Treatment for women with anovulation is aimed at induction of ovulation. Ovulation induction with follicle-stimulating hormone (FSH) is indicated in women with WHO type II anovulation in whom treatment with clomifene citrate (clomifene) has

  14. Inductance loop and partial

    CERN Document Server

    Paul, Clayton R

    2010-01-01

    "Inductance is an unprecedented text, thoroughly discussing "loop" inductance as well as the increasingly important "partial" inductance. These concepts and their proper calculation are crucial in designing modern high-speed digital systems. World-renowned leader in electromagnetics Clayton Paul provides the knowledge and tools necessary to understand and calculate inductance." "With the present and increasing emphasis on high-speed digital systems and high-frequency analog systems, it is imperative that system designers develop an intimate understanding of the concepts and methods in this book. Inductance is a much-needed textbook designed for senior and graduate-level engineering students, as well as a hands-on guide for working engineers and professionals engaged in the design of high-speed digital and high-frequency analog systems."--Jacket.

  15. Half Bridge Inductive Heater

    Directory of Open Access Journals (Sweden)

    Zoltán GERMÁN-SALLÓ

    2015-12-01

    Full Text Available Induction heating performs contactless, efficient and fast heating of conductive materials, therefore became one of the preferred heating procedure in industrial, domestic and medical applications. During induction heating the high-frequency alternating currents that heat the material are induced by means of electromagnetic induction. The material to be heated is placed inside the time-varying magnetic field generated by applying a highfrequency alternating current to an induction coil. The alternating electromagnetic field induces eddy currents in the workpiece, resulting resistive losses, which then heat the material. This paper describes the design of a power electronic converter circuit for induction heating equipment and presents the obtained results. The realized circuit is a low power half bridge resonant inverter which uses power MOS transistors and adequate driver circuits.

  16. Extraction chromatography of actinides

    International Nuclear Information System (INIS)

    Muller, W.

    1978-01-01

    Extraction chromatography of actinides in the oxidation state from 2 to 6 is reviewed. Data on using neutral (tbp), basic (substituted ammonium salts) and acidic [di-(2-ethylhexyl)-phosphoric acid (D2EHPA)] extracting agents ketones, esters, alcohols and β-diketones in this method are given. Using the example of actinide separation using D2EHPA, discussed are factors influencing the efficiency of their chromatography separation (nature and particle size of the carrier materials, extracting agents amount on the carrier, temperature and elution rate)

  17. Micellar liquid chromatography

    International Nuclear Information System (INIS)

    Basova, Elena M; Ivanov, Vadim M; Shpigun, Oleg A

    1999-01-01

    Background and possibilities of practical applications of micellar liquid chromatography (MLC) are considered. Various retention models in MLC, the effects of the nature and concentration of surfactants and organic modifiers, pH, temperature and ionic strength on the MLC efficiency and selectivity are discussed. The advantages and limitations of MLC are demonstrated. The performance of MLC is critically evaluated in relationship to the reversed-phase HPLC and ion-pair chromatography. The potential of application of MLC for the analysis of pharmaceuticals including that in biological fluids and separation of inorganic anions, transition metal cations, metal chelates and heteropoly compounds is described. The bibliography includes 146 references.

  18. Review of induction LINACS

    International Nuclear Information System (INIS)

    Faltens, A.; Keefe, D.

    1981-10-01

    There has been a recent upsurge of activity in the field of induction linacs, with several new machines becoming operational and others in the design stages. The performance levels of electron machines have reached 10's of kiloamps of current and will soon reach 10's of MeV's of energy. Acceleration of ion current has been demonstrated, and the study of a 10 GeV heavy ion induction linac for ICF continues. The operating principles of induction linacs are reviewed with the emphasis on design choices which are important for increasing the maximum beam currents

  19. Review of induction linacs

    International Nuclear Information System (INIS)

    Faltens, A.; Keefe, D.

    1982-01-01

    There has been a recent upsurge of activity in the field of induction linacs, with several new machines becoming operational and others in the design stages. The performance levels of electron machines have reached 10's of kiloamps of current and will soon reach 10's of MeV's of energy. Acceleration of several kiloamps of ion current has been demonstrated, and the study of a 10 GeV heavy ion induction linac for ICF continues. The operating principles of induction linacs are reviewed with the emphasis on design choices which are important for increasing the maximum beam currents

  20. Properties of inductive reasoning.

    Science.gov (United States)

    Heit, E

    2000-12-01

    This paper reviews the main psychological phenomena of inductive reasoning, covering 25 years of experimental and model-based research, in particular addressing four questions. First, what makes a case or event generalizable to other cases? Second, what makes a set of cases generalizable? Third, what makes a property or predicate projectable? Fourth, how do psychological models of induction address these results? The key results in inductive reasoning are outlined, and several recent models, including a new Bayesian account, are evaluated with respect to these results. In addition, future directions for experimental and model-based work are proposed.

  1. performance liquid chromatography

    African Journals Online (AJOL)

    user

    2010-11-22

    Nov 22, 2010 ... ISSN 1684–5315 © 2010 Academic Journals. Full Length Research Paper. Determination ... Key words: Processed food, high-performance liquid chromatography, acrylamide, health hazard. INTRODUCTION. In the year 2002, the ... potatoes, breakfast cereals etc. It was thus confirmed that acrylamide has ...

  2. Induction melter apparatus

    Science.gov (United States)

    Roach, Jay A [Idaho Falls, ID; Richardson, John G [Idaho Falls, ID; Raivo, Brian D [Idaho Falls, ID; Soelberg, Nicholas R [Idaho Falls, ID

    2008-06-17

    Apparatus and methods of operation are provided for a cold-crucible-induction melter for vitrifying waste wherein a single induction power supply may be used to effect a selected thermal distribution by independently energizing at least two inductors. Also, a bottom drain assembly may be heated by an inductor and may include an electrically resistive heater. The bottom drain assembly may be cooled to solidify molten material passing therethrough to prevent discharge of molten material therefrom. Configurations are provided wherein the induction flux skin depth substantially corresponds with the central longitudinal axis of the crucible. Further, the drain tube may be positioned within the induction flux skin depth in relation to material within the crucible or may be substantially aligned with a direction of flow of molten material within the crucible. An improved head design including four shells forming thermal radiation shields and at least two gas-cooled plenums is also disclosed.

  3. Linear induction accelerator

    Science.gov (United States)

    Buttram, M.T.; Ginn, J.W.

    1988-06-21

    A linear induction accelerator includes a plurality of adder cavities arranged in a series and provided in a structure which is evacuated so that a vacuum inductance is provided between each adder cavity and the structure. An energy storage system for the adder cavities includes a pulsed current source and a respective plurality of bipolar converting networks connected thereto. The bipolar high-voltage, high-repetition-rate square pulse train sets and resets the cavities. 4 figs.

  4. Linear induction accelerators

    International Nuclear Information System (INIS)

    Briggs, R.J.

    1986-06-01

    The development of linear induction accelerators has been motivated by applications requiring high-pulsed currents of charged particles at voltages exceeding the capability of single-stage, diode-type accelerators and at currents too high for rf accelerators. In principle, one can accelerate charged particles to arbitrarily high voltages using a multi-stage induction machine, but the 50-MeV, 10-kA Advanced Test Accelerator (ATA) at LLNL is the highest voltage machine in existence at this time. The advent of magnetic pulse power systems makes sustained operation at high-repetition rates practical, and this capability for high-average power is very likely to open up many new applications of induction machines in the future. This paper surveys the US induction linac technology with primary emphasis on electron machines. A simplified description of how induction machines couple energy to the electron beam is given, to illustrate many of the general issues that bound the design space of induction linacs

  5. Arsenic speciation by liquid chromatography coupled with ionspray tandem mass spectrometry

    DEFF Research Database (Denmark)

    Corr, J. J.; Larsen, Erik Huusfeldt

    1996-01-01

    Ionspray mass spectrometry, a well established organic analysis technique, has been coupled to high-performance liquid chromatography for speciation of organic arsenic compounds, The ionspray source and differentially pumped interface of the mass spectrometer were operated in dual modes...... fragmentation patterns showing molecular dissociation through an expected common product ion were obtained for the four arsenosugars, Molecular mode detection was utilized for qualitative verification of speciation analysis by high-performance liquid chromatography coupled to inductively coupled plasma mass...

  6. Chromatography in Industry

    Science.gov (United States)

    Schoenmakers, Peter

    2009-07-01

    This review focuses on the chromatography research that has been carried out within industry or in close cooperation with industry and that has been reported in the scientific literature between 2006 and mid-2008. Companies in the health care sector, such as pharmaceutical and biotechnology companies, are the largest contributors. Industrial research seems to take place in an open environment in cooperation with academia, peer companies, and institutions. Industry appears ready to embrace new technologies as they emerge, but they focus strongly on making chromatography work robustly, reliably, rapidly, and automatically. “Hyphenated” systems that incorporate on-line sample-preparation techniques and mass-spectrometric detection are the rule rather than the exception. Various multidimensional separation methods are finding numerous applications. Strategies aimed at speeding up the development of new chromatographic methods remain the focus of attention. Also, there is a clear trend toward exploring chromatographic methods for parallel processing along with other strategies for high-throughput analysis.

  7. Inductive dielectric analyzer

    International Nuclear Information System (INIS)

    Agranovich, Daniel; Popov, Ivan; Ben Ishai, Paul; Feldman, Yuri; Polygalov, Eugene

    2017-01-01

    One of the approaches to bypass the problem of electrode polarization in dielectric measurements is the free electrode method. The advantage of this technique is that, the probing electric field in the material is not supplied by contact electrodes, but rather by electromagnetic induction. We have designed an inductive dielectric analyzer based on a sensor comprising two concentric toroidal coils. In this work, we present an analytic derivation of the relationship between the impedance measured by the sensor and the complex dielectric permittivity of the sample. The obtained relationship was successfully employed to measure the dielectric permittivity and conductivity of various alcohols and aqueous salt solutions. (paper)

  8. Modeling Induction Motor Imbalances

    DEFF Research Database (Denmark)

    Armah, Kabenla; Jouffroy, Jerome; Duggen, Lars

    2016-01-01

    This paper gives a study into the development of a generalized model for a three-phase induction motor that offers flexibility of simulating balanced and unbalanced parameter scenarios. By analyzing the interaction of forces within the motor, we achieve our main objective of deriving the system d...

  9. High current induction linacs

    International Nuclear Information System (INIS)

    Barletta, W.; Faltens, A.; Henestroza, E.; Lee, E.

    1994-07-01

    Induction linacs are among the most powerful accelerators in existence. They have accelerated electron bunches of several kiloamperes, and are being investigated as drivers for heavy ion driven inertial confinement fusion (HIF), which requires peak beam currents of kiloamperes and average beam powers of some tens of megawatts. The requirement for waste transmutation with an 800 MeV proton or deuteron beam with an average current of 50 mA and an average power of 40 MW lies midway between the electron machines and the heavy ion machines in overall difficulty. Much of the technology and understanding of beam physics carries over from the previous machines to the new requirements. The induction linac allows use of a very large beam aperture, which may turn out to be crucial to reducing beam loss and machine activation from the beam halo. The major issues addressed here are transport of high intensity beams, availability of sources, efficiency of acceleration, and the state of the needed technology for the waste treatment application. Because of the transformer-like action of an induction core and the accompanying magnetizing current, induction linacs make the most economic sense and have the highest efficiencies with large beam currents. Based on present understanding of beam transport limits, induction core magnetizing current requirements, and pulse modulators, the efficiencies could be very high. The study of beam transport at high intensities has been the major activity of the HIF community. Beam transport and sources are limiting at low energies but are not significant constraints at the higher energies. As will be shown, the proton beams will be space-charge-dominated, for which the emittance has only a minor effect on the overall beam diameter but does determine the density falloff at the beam edge

  10. Spiral Countercurrent Chromatography

    Science.gov (United States)

    Ito, Yoichiro; Knight, Martha; Finn, Thomas M.

    2013-01-01

    For many years, high-speed countercurrent chromatography conducted in open tubing coils has been widely used for the separation of natural and synthetic compounds. In this method, the retention of the stationary phase is solely provided by the Archimedean screw effect by rotating the coiled column in the centrifugal force field. However, the system fails to retain enough of the stationary phase for polar solvent systems such as the aqueous–aqueous polymer phase systems. To address this problem, the geometry of the coiled channel was modified to a spiral configuration so that the system could utilize the radially acting centrifugal force. This successfully improved the retention of the stationary phase. Two different types of spiral columns were fabricated: the spiral disk assembly, made by stacking multiple plastic disks with single or four interwoven spiral channels connected in series, and the spiral tube assembly, made by inserting the tetrafluoroethylene tubing into a spiral frame (spiral tube support). The capabilities of these column assemblies were successfully demonstrated by separations of peptides and proteins with polar two-phase solvent systems whose stationary phases had not been well retained in the earlier multilayer coil separation column for high-speed countercurrent chromatography. PMID:23833207

  11. Inductive Communication System Design Summary

    Science.gov (United States)

    1978-09-01

    The report documents the experience obtained during the design and development of the Inductive Communications System used in the Morgantown People Mover. The Inductive Communications System is used to provide wayside-to-vehicle and vehicle-to-waysid...

  12. Induction technology optimization code

    International Nuclear Information System (INIS)

    Caporaso, G.J.; Brooks, A.L.; Kirbie, H.C.

    1992-01-01

    A code has been developed to evaluate relative costs of induction accelerator driver systems for relativistic klystrons. The code incorporates beam generation, transport and pulsed power system constraints to provide an integrated design tool. The code generates an injector/accelerator combination which satisfies the top level requirements and all system constraints once a small number of design choices have been specified (rise time of the injector voltage and aspect ratio of the ferrite induction cores, for example). The code calculates dimensions of accelerator mechanical assemblies and values of all electrical components. Cost factors for machined parts, raw materials and components are applied to yield a total system cost. These costs are then plotted as a function of the two design choices to enable selection of an optimum design based on various criteria. (Author) 11 refs., 3 figs

  13. Glass manufacturing through induction

    International Nuclear Information System (INIS)

    Boen, R.; Paya, B.; Roscini, M.; Fautrelle, Y.; Tuaz, F.; Delage, D.

    1991-01-01

    Oxides and glasses are electrical and thermal insulators, but show the characteristic of being weakly conductors of electricity when they are melt. It is then possible to heat them through HF induction. This interesting property allows the development of a melting process in cold crucible induction furnace. The process is being studied and developed by a consortium made up of CFEI, CEA Marcoule, ELECTRICITE DE FRANCE and MADYLAM laboratory. The studies include 2 parts: a) One experimental part to develop the technology and research for satisfying configurations, through a small size platform (10 to 30 kg/h). The long run continuous pouring melting tests made on different kinds of glass allow to go-on with industrial range units. b) One theoretical part to understand the magneto-thermo-hydraulic phenomenon hardly in relation with the heavy dependence of the physical characteristics (electrical and heat conductivities, viscosity) according to temperature. 6 refs., 4 figs [fr

  14. Inductive energy storage commutator

    International Nuclear Information System (INIS)

    Gavrilov, I.M.

    1987-01-01

    An inductive energy storage commutator is described. The value of commutated current is up to 800 A, the voltage amplitude in the load is up to 50 kV, the working frequency is equal to 1-50 Hz, the commutated power is up to 40 MW. The commutating device comprises of the first stage commutator having two in-series connected modules of the BTSV - 800/235 high-voltage thyristor unit, the second stage commutator containing three GMI-43A parallel connected powerful pulsed triodes, a commutating capacitor, an induction coil, two supplementary high-voltage thyristor keys (20 in-series connected thyristors T2-300 (13 class)), load, control pulse shapers, thyristor keys, power supply

  15. Pulse induction heating

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, A S; Kachanov, B Y; Kogan, B V

    1993-12-31

    Induction heating and three types of pulse processes were studied. It was found that in pulse processes the frequency and pulse duration of heat treatments do not remain constant. High frequency pulse heat treatments can be used on sprayed coatings; such treatments will result in stronger surfaces with no cracks. For induction hardening, the rate of specific power was 1 to 1.5 kW/sq.cm, for forging it was 0.2 to 0.3 kW/sq.cm and for melting it was 0.05 to 0.1 kW/sq.cm. The application of pulse heating will result in higher rates of specific power.

  16. Inductive Reasoning: A Training Approach

    Science.gov (United States)

    Klauer, Karl Josef; Phye, Gary D.

    2008-01-01

    Researchers have examined inductive reasoning to identify different cognitive processes when participants deal with inductive problems. This article presents a prescriptive theory of inductive reasoning that identifies cognitive processing using a procedural strategy for making comparisons. It is hypothesized that training in the use of the…

  17. Lexicographic Path Induction

    DEFF Research Database (Denmark)

    Schürmann, Carsten; Sarnat, Jeffrey

    2009-01-01

    Programming languages theory is full of problems that reduce to proving the consistency of a logic, such as the normalization of typed lambda-calculi, the decidability of equality in type theory, equivalence testing of traces in security, etc. Although the principle of transfinite induction......, and weak normalization for Gödel’s T follows indirectly; both have been formalized in a prototypical extension of Twelf....

  18. Diagnostics for induction accelerators

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1996-04-01

    The induction accelerator was conceived by N. C. Christofilos and first realized as the Astron accelerator that operated at LLNL from the early 1960's to the end of 1975. This accelerator generated electron beams at energies near 6 MeV with typical currents of 600 Amperes in 400 ns pulses. The Advanced Test Accelerator (ATA) built at Livermore's Site 300 produced 10,000 Ampere beams with pulse widths of 70 ns at energies approaching 50 MeV. Several other electron and ion induction accelerators have been fabricated at LLNL and LBNL. This paper reviews the principal diagnostics developed through efforts by scientists at both laboratories for measuring the current, position, energy, and emittance of beams generated by these high current, short pulse accelerators. Many of these diagnostics are closely related to those developed for other accelerators. However, the very fast and intense current pulses often require special diagnostic techniques and considerations. The physics and design of the more unique diagnostics developed for electron induction accelerators are presented and discussed in detail

  19. Diagnostics for induction accelerators

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1997-01-01

    The induction accelerator was conceived by N. C. Christofilos and first realized as the Astron accelerator that operated at Lawrence Livermore National Laboratory (LLNL) from the early 1960s to the end of 1975. This accelerator generated electron beams at energies near 6 MeV with typical currents of 600 Amperes in 400-ns pulses. The Advanced Test Accelerator (ATA) built at Livermore close-quote s Site 300 produced 10,000-Ampere beams with pulse widths of 70 ns at energies approaching 50 MeV. Several other electron and ion induction accelerators have been fabricated at LLNL and Lawrence Berkeley National Laboratory (LBNL). This paper reviews the principal diagnostics developed through efforts by scientists at both laboratories for measuring the current, position, energy, and emittance of beams generated by these high-current, short-pulse accelerators. Many of these diagnostics are closely related to those developed for other accelerators. However, the very fast and intense current pulses often require special diagnostic techniques and considerations. The physics and design of the more unique diagnostics developed for electron induction accelerators are presented and discussed in detail. copyright 1997 American Institute of Physics

  20. Multiplex gas chromatography

    Science.gov (United States)

    Valentin, Jose R.

    1990-01-01

    The principles of the multiplex gas chromatography (GC) technique, which is a possible candidate for chemical analysis of planetary atmospheres, are discussed. Particular attention is given to the chemical modulators developed by present investigators for multiplex GC, namely, the thermal-desorption, thermal-decomposition, and catalytic modulators, as well as to mechanical modulators. The basic technique of multiplex GC using chemical modulators and a mechanical modulator is demonstrated. It is shown that, with the chemical modulators, only one gas stream consisting of the carrier in combination with the components is being analyzed, resulting in a simplified instrument that requires relatively few consumables. The mechanical modulator demonstrated a direct application of multiplex GC for the analysis of gases in atmosphere of Titan at very low pressures.

  1. Dielectrokinetic chromatography devices

    Science.gov (United States)

    Chirica, Gabriela S; Fiechtner, Gregory J; Singh, Anup K

    2014-12-16

    Disclosed herein are methods and devices for dielectrokinetic chromatography. As disclosed, the devices comprise microchannels having at least one perturber which produces a non-uniformity in a field spanning the width of the microchannel. The interaction of the field non-uniformity with a perturber produces a secondary flow which competes with a primary flow. By decreasing the size of the perturber the secondary flow becomes significant for particles/analytes in the nanometer-size range. Depending on the nature of a particle/analyte present in the fluid and its interaction with the primary flow and the secondary flow, the analyte may be retained or redirected. The composition of the primary flow can be varied to affect the magnitude of primary and/or secondary flows on the particles/analytes and thereby separate and concentrate it from other particles/analytes.

  2. Determination of radiochemical purity using gas chromatography

    International Nuclear Information System (INIS)

    1975-01-01

    The concepts of chromatography, gas chromatography, activity, radiochemical impurity are defined; the procedure of the application of gas chromatography for detecting radiochemical purity of substances is standardized. (E.F.)

  3. Inductive reasoning 2.0.

    Science.gov (United States)

    Hayes, Brett K; Heit, Evan

    2018-05-01

    Inductive reasoning entails using existing knowledge to make predictions about novel cases. The first part of this review summarizes key inductive phenomena and critically evaluates theories of induction. We highlight recent theoretical advances, with a special emphasis on the structured statistical approach, the importance of sampling assumptions in Bayesian models, and connectionist modeling. A number of new research directions in this field are identified including comparisons of inductive and deductive reasoning, the identification of common core processes in induction and memory tasks and induction involving category uncertainty. The implications of induction research for areas as diverse as complex decision-making and fear generalization are discussed. This article is categorized under: Psychology > Reasoning and Decision Making Psychology > Learning. © 2017 Wiley Periodicals, Inc.

  4. A taxonomy of inductive problems.

    Science.gov (United States)

    Kemp, Charles; Jern, Alan

    2014-02-01

    Inductive inferences about objects, features, categories, and relations have been studied for many years, but there are few attempts to chart the range of inductive problems that humans are able to solve. We present a taxonomy of inductive problems that helps to clarify the relationships between familiar inductive problems such as generalization, categorization, and identification, and that introduces new inductive problems for psychological investigation. Our taxonomy is founded on the idea that semantic knowledge is organized into systems of objects, features, categories, and relations, and we attempt to characterize all of the inductive problems that can arise when these systems are partially observed. Recent studies have begun to address some of the new problems in our taxonomy, and future work should aim to develop unified theories of inductive reasoning that explain how people solve all of the problems in the taxonomy.

  5. Linear induction motor

    International Nuclear Information System (INIS)

    Barkman, W.E.; Adams, W.Q.; Berrier, B.R.

    1978-01-01

    A linear induction motor has been operated on a test bed with a feedback pulse resolution of 5 nm (0.2 μin). Slewing tests with this slide drive have shown positioning errors less than or equal to 33 nm (1.3 μin) at feedrates between 0 and 25.4 mm/min (0-1 ipm). A 0.86-m (34-in)-stroke linear motor is being investigated, using the SPACO machine as a test bed. Initial results were encouraging, and work is continuing to optimize the servosystem compensation

  6. Antibody induction versus corticosteroid induction for liver transplant recipients

    DEFF Research Database (Denmark)

    Penninga, Luit; Wettergren, André; Wilson, Colin H

    2014-01-01

    BACKGROUND: Liver transplantation is an established treatment option for end-stage liver failure. To date, no consensus has been reached on the use of immunosuppressive T-cell specific antibody induction compared with corticosteroid induction of immunosuppression after liver transplantation....... OBJECTIVES: To assess the benefits and harms of T-cell specific antibody induction versus corticosteroid induction for prevention of acute rejection in liver transplant recipients. SEARCH METHODS: We searched The Cochrane Hepato-Biliary Group Controlled Trials Register, the Cochrane Central Register...... to identify additional trials. SELECTION CRITERIA: We included all randomised clinical trials assessing immunosuppression with T-cell specific antibody induction versus corticosteroid induction in liver transplant recipients. Our inclusion criteria stated that participants within each included trial should...

  7. Enantioseparations in counter-current chromatography and centrifugal partition chromatography.

    Science.gov (United States)

    Foucault, A P

    2001-01-12

    Examples of chiral separations in counter-current chromatography (CCC) and centrifugal partition chromatography (CPC) are not numerous, due to the difficulty of finding chiral selectors highly selective in the liquid phase as well as a combination of solvents that does not destroy the selectivity and retains the capacity to elute chiral isomers of interest. New ideas and new chiral selectors generally come from other separation techniques, as will be highlighted in this review.

  8. Centrifugal precipitation chromatography

    Science.gov (United States)

    Ito, Yoichiro; Lin, Qi

    2009-01-01

    Centrifugal precipitation chromatography separates analytes according their solubility in ammonium sulfate (AS) solution and other precipitants. The separation column is made from a pair of long spiral channels partitioned with a semipermeable membrane. In a typical separation, concentrated ammonium sulfate is eluted through one channel while water is eluted through the other channel in the opposite direction. The countercurrent process forms an exponential AS concentration gradient through the water channel. Consequently, protein samples injected into the water channel is subjected to a steadily increasing AS concentration and at the critical AS concentration they are precipitated and deposited in the channel bed by the centrifugal force. Then the chromatographic separation is started by gradually reducing the AS concentration in the AS channel which lowers the AS gradient concentration in the water channel. This results in dissolution of deposited proteins which are again precipitated at an advanced critical point as they move through the channel. Consequently, proteins repeat precipitation and dissolution through a long channel and finally eluted out from the column in the order of their solubility in the AS solution. The present method has been successfully applied to a number of analytes including human serum proteins, recombinant ketosteroid isomerase, carotenoid cleavage enzymes, plasmid DNA, polysaccharide, polymerized pigments, PEG-protein conjugates, etc. The method is capable to single out the target species of proteins by affinity ligand or immunoaffinity separation. PMID:19541553

  9. Microemulsion Electrokinetic Chromatography.

    Science.gov (United States)

    Buchberger, Wolfgang

    2016-01-01

    Microemulsion electrokinetic chromatography (MEEKC) is a special mode of capillary electrophoresis employing a microemulsion as carrier electrolyte. Analytes may partition between the aqueous phase of the microemulsion and its oil droplets which act as a pseudostationary phase. The technique is well suited for the separation of neutral species, in which case charged oil droplets (obtained by addition of an anionic or cationic surfactant) are present. A single set of separation parameters may be sufficient for separation of a wide range of analytes belonging to quite different chemical classes. Fine-tuning of resolution and analysis time may be achieved by addition of organic solvents, by changes in the nature of the surfactants (and cosurfactants) used to stabilize the microemulsion, or by various additives that may undergo some additional interactions with the analytes. Besides the separation of neutral analytes (which may be the most important application area of MEEKC), it can also be employed for cationic and/or anionic species. In this chapter, MEEKC conditions are summarized that have proven their reliability for routine analysis. Furthermore, the mechanisms encountered in MEEKC allow an efficient on-capillary preconcentration of analytes, so that the problem of poor concentration sensitivity of ultraviolet absorbance detection is circumvented.

  10. Pulsed inductive HF laser

    Energy Technology Data Exchange (ETDEWEB)

    Razhev, A M; Kargapol' tsev, E S [Institute of Laser Physics, Siberian Branch, Russian Academy of Sciences, Novosibirsk (Russian Federation); Churkin, D S; Demchuk, S V [Novosibirsk State University, Novosibirsk (Russian Federation)

    2016-03-31

    We report the results of experimentally investigated dependences of temporal, spectral and spatial characteristics of an inductive HF-laser generation on the pump conditions. Gas mixtures H{sub 2} – F{sub 2}(NF{sub 3} or SF6{sub 6}) and He(Ne) – H{sub 2} – F{sub 2}(NF{sub 3} or SF{sub 6}) were used as active media. The FWHM pulse duration reached 0.42 μs. This value corresponded to a pulsed power of 45 kW. For the first time, the emission spectrum of an inductive HF laser was investigated, which consisted of seven groups of bands with centres around the wavelengths of 2732, 2736, 2739, 2835, 2837, 2893 and 2913 nm. The cross section profile of the laser beam was a ring with a diameter of about 20 mm and width of about 5 mm. Parameters of laser operation in the repetitively pulsed regime were sufficiently stable. The amplitude instability of light pulses was no greater than 5% – 6%. (lasers)

  11. Regulation of ATM induction

    International Nuclear Information System (INIS)

    Clarke, R.A.; Fang, Z.M.; Kearsley, J.H.; Lee, C.S.; Sarris, M.; De Murrell, D.

    2000-01-01

    Full text: ATM, the tumour suppressor protein mutated in ataxia-telangiectasia, is of pivotal importance in controlling the cells primary response to ionising radiation (IR) induced DNA damage. Mutations in ATM which reduce the level of the ATM protein and/or compromise ATM functions are known to give rise to radiosensitivity and defective cell cycle checkpoint control. In response to DNA damage ATM kinase is rapidly activated and initiates downstream signalling to cell cycle control molecules including p53. To investigate additional mechanisms of ATM control we have employed ATM antisense expression in cultured cells, western analyses and immunohistochemistry in situ. We report that ATM can be up-regulated up to 10-fold following exposure to low levels of ionising radiation. ATM radiation-induction was radiation dose dependent while the rapidity of the response indicates a post translational pathway. The concurrent time frames for the radiation-induction of ATM levels and the activation of ATM kinase activity appear to be complimentary in boosting ATM's protective response to IR induced DNA damage, especially in ATM 'low expressing' systems. We also provide the first report of ATM misregulation in 2 cancer patients, indicating that ATM is not only radio-protective but has possible implications in cancer, particularly breast cancer. These results have particular importance in defining the regulation of the ATM protein as an: adaptive radio-response; radio-prognostic market in tumours and normal tissue, and breast cancer marker

  12. Introduction to modern liquid chromatography

    National Research Council Canada - National Science Library

    Snyder, Lloyd R; Kirkland, J. J; Dolan, John W

    2010-01-01

    "High-performance liquid chromatography (HPLC) is today the leading technique for chemical analysis and related applications, with an ability to separate, analyze, and/or purify virtually any sample...

  13. Gas chromatography: mass selective detector

    International Nuclear Information System (INIS)

    Lapinskas, R.

    1988-01-01

    The mechanism of mass spectrometry technique directed for detecting molecular structures is described, with some considerations about its operational features. This mass spectrometer is used as a gas chromatography detector. (author)

  14. Calcium-sensitive immunoaffinity chromatography

    DEFF Research Database (Denmark)

    Henriksen, Maiken L; Lindhardt Madsen, Kirstine; Skjoedt, Karsten

    2014-01-01

    Immunoaffinity chromatography is a powerful fractionation technique that has become indispensable for protein purification and characterization. However, it is difficult to retrieve bound proteins without using harsh or denaturing elution conditions, and the purification of scarce antigens...... to homogeneity may be impossible due to contamination with abundant antigens. In this study, we purified the scarce, complement-associated plasma protein complex, collectin LK (CL-LK, complex of collectin liver 1 and kidney 1), by immunoaffinity chromatography using a calcium-sensitive anti-collectin-kidney-1 m...... chromatography was superior to the traditional immunoaffinity chromatographies and resulted in a nine-fold improvement of the purification factor. The technique is applicable for the purification of proteins in complex mixtures by single-step fractionation without the denaturation of eluted antigens...

  15. Flow Rates in Liquid Chromatography, Gas Chromatography and Supercritical Fluid Chromatography: A Tool for Optimization

    Directory of Open Access Journals (Sweden)

    Joris Meurs

    2016-08-01

    Full Text Available This paper aimed to develop a standalone application for optimizing flow rates in liquid chromatography (LC, gas chromatography (GC and supercritical fluid chromatography (SFC. To do so, Van Deemter’s equation, Knox’ equation and Golay’s equation were implemented in a MATLAB script and subsequently a graphical user interface (GUI was created. The application will show the optimal flow rate or linear velocity and the corresponding plate height for the set input parameters. Furthermore, a plot will be shown in which the plate height is plotted against the linear flow velocity. Hence, this application will give optimized flow rates for any set conditions with minimal effort.

  16. Vector control of induction machines

    CERN Document Server

    Robyns, Benoit

    2012-01-01

    After a brief introduction to the main law of physics and fundamental concepts inherent in electromechanical conversion, ""Vector Control of Induction Machines"" introduces the standard mathematical models for induction machines - whichever rotor technology is used - as well as several squirrel-cage induction machine vector-control strategies. The use of causal ordering graphs allows systematization of the design stage, as well as standardization of the structure of control devices. ""Vector Control of Induction Machines"" suggests a unique approach aimed at reducing parameter sensitivity for

  17. Borehole induction coil transmitter

    Science.gov (United States)

    Holladay, Gale; Wilt, Michael J.

    2002-01-01

    A borehole induction coil transmitter which is a part of a cross-borehole electromagnetic field system that is used for underground imaging applications. The transmitter consists of four major parts: 1) a wound ferrite or mu-metal core, 2) an array of tuning capacitors, 3) a current driver circuit board, and 4) a flux monitor. The core is wound with several hundred turns of wire and connected in series with the capacitor array, to produce a tuned coil. This tuned coil uses internal circuitry to generate sinusoidal signals that are transmitted through the earth to a receiver coil in another borehole. The transmitter can operate at frequencies from 1-200 kHz and supplies sufficient power to permit the field system to operate in boreholes separated by up to 400 meters.

  18. Inductive circuit arrangements

    International Nuclear Information System (INIS)

    Mansfield, Peter; Coxon, R.J.

    1987-01-01

    A switched coil arrangement is connected in a bridge configuration of four switches S 1 , S 2 , S 3 and S 4 which are each shunted by diodes D 1 , D 2 , D 3 and D 4 so that current can flow in either direction through a coil L depending on the setting of the switches. A capacitor C is connected across the bridge through a switch S 5 to receive the inductive energy stored in coil L on breaking the current flow path through the coil. The electrostatic energy stored in capacitor C can then be used to supply current through the coil in the reverse direction either immediately or after a time delay. Coil L may be a superconductive coil. Losses in the circuit can be made up by a trickle charge of capacitor C from a separate supply V 2 . The device may be used in nuclear magnetic resonance imaging. (author)

  19. Induction heating using induction coils in series-parallel circuits

    Science.gov (United States)

    Matsen, Marc Rollo; Geren, William Preston; Miller, Robert James; Negley, Mark Alan; Dykstra, William Chet

    2017-11-14

    A part is inductively heated by multiple, self-regulating induction coil circuits having susceptors, coupled together in parallel and in series with an AC power supply. Each of the circuits includes a tuning capacitor that tunes the circuit to resonate at the frequency of AC power supply.

  20. Probabilistic inductive inference: a survey

    OpenAIRE

    Ambainis, Andris

    2001-01-01

    Inductive inference is a recursion-theoretic theory of learning, first developed by E. M. Gold (1967). This paper surveys developments in probabilistic inductive inference. We mainly focus on finite inference of recursive functions, since this simple paradigm has produced the most interesting (and most complex) results.

  1. A Student Teamwork Induction Protocol

    Science.gov (United States)

    Kamau, Caroline; Spong, Abigail

    2015-01-01

    Faulty group processes have harmful effects on performance but there is little research about intervention protocols to pre-empt them in higher education. This naturalistic experiment compared a control cohort with an inducted cohort. The inducted cohort attended a workshop, consultations, elected a leader and used tools (a group log and group…

  2. Sampling Assumptions in Inductive Generalization

    Science.gov (United States)

    Navarro, Daniel J.; Dry, Matthew J.; Lee, Michael D.

    2012-01-01

    Inductive generalization, where people go beyond the data provided, is a basic cognitive capability, and it underpins theoretical accounts of learning, categorization, and decision making. To complete the inductive leap needed for generalization, people must make a key "sampling" assumption about how the available data were generated.…

  3. From Inductive Reasoning to Proof

    Science.gov (United States)

    Yopp, David A.

    2009-01-01

    Mathematical proof is an expression of deductive reasoning (drawing conclusions from previous assertions). However, it is often inductive reasoning (conclusions drawn on the basis of examples) that helps learners form their deductive arguments, or proof. In addition, not all inductive arguments generate more formal arguments. This article draws a…

  4. Covariation in Natural Causal Induction.

    Science.gov (United States)

    Cheng, Patricia W.; Novick, Laura R.

    1991-01-01

    Biases and models usually offered by cognitive and social psychology and by philosophy to explain causal induction are evaluated with respect to focal sets (contextually determined sets of events over which covariation is computed). A probabilistic contrast model is proposed as underlying covariation computation in natural causal induction. (SLD)

  5. Economic implications of labor induction.

    Science.gov (United States)

    Garcia-Simon, Raquel; Montañes, Antonio; Clemente, Jesús; Del Pino, María D; Romero, Manuel A; Fabre, Ernesto; Oros, Daniel

    2016-04-01

    To assess health service costs associated with labor induction according to different clinical situations in a tertiary-level hospital. In a prospective study, individual patient cost data were assessed for women admitted for induction of labor at a tertiary hospital in Spain between November 1, 2012, and August 31, 2013. The costs of labor induction were estimated according to maternal and neonatal outcomes, method of delivery, cervical condition at admission, and obstetric indication. Direct costs including professional fees, epidural, maternal stay, consumables, and drugs were calculated. Overall, 412 women were included in the final cost analysis. The mean total cost of labor induction was €3589.87 (95% confidence interval [CI] 3475.13-3704.61). Cesarean delivery after labor induction (€4830.45, 95% CI 4623.13-5037.58) was significantly more expensive than spontaneous delivery (€3037.45, 95% CI 2966.91-3179.99) and instrumental vaginal delivery (€3344.31, 95%CI 3151.69-3536.93). The total cost for patients with a very unfavorable cervix (Bishop score Labor induction for hypertensive disorders of pregnancy was the most expensive obstetric indication for induction of labor (€4347.32, 95% CI 3890.45-4804.18). Following the induction of labor, a number of patient- and treatment-related factors influence costs associated with delivery. Copyright © 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  6. Interferon induction by adenoviruses

    Energy Technology Data Exchange (ETDEWEB)

    Beladi, I; Bakay, M; Pusztai, R; Mucsi, I; Tarodi, B [University Medical School, Szeged (Hungary). Inst. of Microbiology

    1979-02-01

    All human, simian, bovine and avian adenovirus types tested so far and the canine hepatitis virus induce interferon production in chick cells. This finding indicated this property to be characteristic for viruses belonging to the adenovirus group. Trypsin treatment, which had no effect upon the infectivity, diminished or eliminated the interferon-inducing abilities of crude adenoviruses, and thus the need for a trypsin-sensitive protein in interferon induction was suggested. T antigen and interferon were formed simultaneously in chick embryo fibroblast cells infected with human adenovirus type 12, and there-fore the adenovirus-specific T antigen was resitant to the action of endogenous interferon synthetized by the same cells. In chicks inoculated with human types, the appearance of interferon was biphasic: an 'early' and a 'late' interferon could be demonstrated with maximum titre 4 and 10 hr, respectively, after virus infection. In chicks infected with adenoviruses, first interferon production and then a decreased primary immune response to sheep red blood cells was observed. It was assumed that in adenovirus-infected chicks the interferon produced by viral stimulus resulted in a transient immunosuppression.

  7. Extraction chromatography of fission products

    International Nuclear Information System (INIS)

    Bonnevie-Svendsen, M.; Goon, K.

    1978-01-01

    Various cases of using extraction chromatography during analysis of fission products are reviewed. The use of the extraction chromatography method is considered while analysing reprocessed products of nuclear fuel for quantitative radiochemical analysis and control of fission product and actinoide separation during extraction and their chemical state in production solutions. The method is used to obtain pure fractions of typical burnup monitors (neodymium, molybdenum, cerium, cesium, europium, lanthanides) during determination of nuclear fuel burnup degree. While studying the nature of nuclear reactions the method is used to separate quickly short-life isotopes, to purify β-radiator fractions before measuring their half-life periods, to enrich isotopes forming with low output during fission. Examples of using extraction chromatography are given to separate long half-life or stable fission products from spent solutions, to control environment object contamination

  8. Capillary gas-solid chromatography

    International Nuclear Information System (INIS)

    Berezkin, V.G.

    1996-01-01

    Modern state of gas adsorption chromatography in open capillary columns has been analyzed. The history of the method development and its role in gas chromatography, ways to construct open adsorptional capillary columns, foundations of the theory of retention and washing of chromatographic regions in gas adsorption capillary columns have been considered. The fields is extensively and for analyzing volatile compounds of different isotopic composition, inorganic and organic gases, volatile organic polar compounds, aqueous solutions of organic compounds. Separation of nuclear-spin isomers and isotopes of hydrogen is the first illustrative example of practical application of the adsorption capillary chromatography. It is shown that duration of protium and deuterium nuclear isomers may be reduced if the column temperature is brought to 47 K

  9. Isotopic separation by ion chromatography

    International Nuclear Information System (INIS)

    Albert, M.G.; Barre, Y.; Neige, R.

    1994-01-01

    The isotopic exchange reaction and the isotopic separation factor are first recalled; the principles of ion chromatography applied to lithium isotope separation are then reviewed (displacement chromatography) and the process is modelled in the view of dimensioning and optimizing the industrial process; the various dimensioning parameters are the isotopic separation factor, the isotopic exchange kinetics and the material flow rate. Effects of the resin type and structure are presented. Dimensioning is also affected by physico-chemical and hydraulic parameters. Industrial implementation features are also discussed. 1 fig., 1 tab., 5 refs

  10. Atomic Force Microscope Mediated Chromatography

    Science.gov (United States)

    Anderson, Mark S.

    2013-01-01

    The atomic force microscope (AFM) is used to inject a sample, provide shear-driven liquid flow over a functionalized substrate, and detect separated components. This is demonstrated using lipophilic dyes and normal phase chromatography. A significant reduction in both size and separation time scales is achieved with a 25-micron-length column scale, and one-second separation times. The approach has general applications to trace chemical and microfluidic analysis. The AFM is now a common tool for ultra-microscopy and nanotechnology. It has also been demonstrated to provide a number of microfluidic functions necessary for miniaturized chromatography. These include injection of sub-femtoliter samples, fluidic switching, and sheardriven pumping. The AFM probe tip can be used to selectively remove surface layers for subsequent microchemical analysis using infrared and tip-enhanced Raman spectroscopy. With its ability to image individual atoms, the AFM is a remarkably sensitive detector that can be used to detect separated components. These diverse functional components of microfluidic manipulation have been combined in this work to demonstrate AFM mediated chromatography. AFM mediated chromatography uses channel-less, shear-driven pumping. This is demonstrated with a thin, aluminum oxide substrate and a non-polar solvent system to separate a mixture of lipophilic dyes. In conventional chromatographic terms, this is analogous to thin-layer chromatography using normal phase alumina substrate with sheardriven pumping provided by the AFM tip-cantilever mechanism. The AFM detection of separated components is accomplished by exploiting the variation in the localized friction of the separated components. The AFM tip-cantilever provides the mechanism for producing shear-induced flows and rapid pumping. Shear-driven chromatography (SDC) is a relatively new concept that overcomes the speed and miniaturization limitations of conventional liquid chromatography. SDC is based on a

  11. Metal-organic frameworks in chromatography.

    Science.gov (United States)

    Yusuf, Kareem; Aqel, Ahmad; ALOthman, Zeid

    2014-06-27

    Metal-organic frameworks (MOFs) emerged approximately two decades ago and are the youngest class of porous materials. Despite their short existence, MOFs are finding applications in a variety of fields because of their outstanding chemical and physical properties. This review article focuses on the applications of MOFs in chromatography, including high-performance liquid chromatography (HPLC), gas chromatography (GC), and other chromatographic techniques. The use of MOFs in chromatography has already had a significant impact; however, the utilisation of MOFs in chromatography is still less common than other applications, and the number of MOF materials explored in chromatography applications is limited. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Inductive line energy storage generator

    Energy Technology Data Exchange (ETDEWEB)

    Choi, P [Ecole Polytechnique, Palaiseau (France). Laboratoire de Physique des Milieux Ionises

    1997-12-31

    The inductive energy storage (IES) generator has long been considered to be the most efficient system for energy usage in large pulsed power system at the MA level. A number of parameters govern the efficiency of energy transfer between the storage capacitors and the load, and the level of current deliverable to the load. For high power system, the energy storage capacitors are arranged as a Marx generator. The primary constraints are the inductances in the various parts of the circuit, in particular, the upstream inductance between the Marx and the POS, and the downstream inductance between the POS and the load. This paper deals with the effect of replacing part of the upstream inductance with a transmission line and introduces the new concept of an inductive line for energy storage (ILES). Extensive parametric scans were carried out on circuit simulations to investigate the effect of this upstream transmission line. A model was developed to explain the operation of the ILES design based on the data obtained. Comparison with an existing IES generator shows that the ILES design offers a significant improvement in the maximum current and hence energy delivered to an inductive load. (author). 5 figs., 1 ref.

  13. Overview of Bearingless Induction Motors

    Directory of Open Access Journals (Sweden)

    Xiaodong Sun

    2014-01-01

    Full Text Available Bearingless induction motors combining functions of both torque generation and noncontact magnetic suspension together have attracted more and more attention in the past decades due to their definite advantages of compactness, simple structure, less maintenance, no wear particles, high rotational speed, and so forth. This paper overviews the key technologies of the bearingless induction motors, with emphasis on motor topologies, mathematical models, and control strategies. Particularly, in the control issues, the vector control, independent control, direct torque control, nonlinear decoupling control, sensorless control, and so forth are investigated. In addition, several possible development trends of the bearingless induction motors are also discussed.

  14. Antibody induction versus placebo, no induction, or another type of antibody induction for liver transplant recipients

    DEFF Research Database (Denmark)

    Penninga, Luit; Wettergren, André; Wilson, Colin H

    2014-01-01

    . All 19 trials were with high risk of bias. Of the 19 trials, 16 trials were two-arm trials, and three trials were three-arm trials. Hence, we found 25 trial comparisons with antibody induction agents: interleukin-2 receptor antagonist (IL-2 RA) versus no induction (10 trials with 1454 participants....... Furthermore, serum creatinine was statistically significantly higher when T-cell specific antibody induction was compared with no induction (MD 3.77 μmol/L, 95% CI 0.33 to 7.21; low-quality evidence), as well as when polyclonal T-cell specific antibody induction was compared with no induction, but this small...... T-cell specific antibody induction, drug-related adverse events were less common among participants treated with interleukin-2 receptor antagonists (RR 0.23, 95% CI 0.09 to 0.63; low-quality evidence), but this was caused by the results from one trial, and trial sequential analysis could not exclude...

  15. Selectivity in microemulsion electrokinetic chromatography

    DEFF Research Database (Denmark)

    Pedersen-Bjergaard, S; Gabel-Jensen, Charlotte; Honoré Hansen, S

    2000-01-01

    Microemulsion electrokinetic chromatography (MEEKC) is a most promising separation technique providing good selectivity and high separation efficiency of anionic, cationic as well as neutral solutes. In MEEKC lipophilic organic solvents dispersed as tiny droplets in an aqueous buffer by the use...

  16. Liquid chromatography in migration studies

    International Nuclear Information System (INIS)

    Carlsen, L.; Batsberg, W.

    1982-01-01

    Liquid chromatography ahs been suggested as a facile experimental technique to determine important physico-chemical properties, as permeability, porosity, dispersion-, diffusion-, and sorption charcteristics for geological material as chalk samples. The feasibility of the trechnique as a rapid method to evaluate the possible influence of changes in ground water composition on the migration behavior of radionuclides has been demonstrated

  17. Liquid phase chromatography on microchips

    DEFF Research Database (Denmark)

    Kutter, Jörg Peter

    2012-01-01

    explosive development of, in particular, chromatographic separation systems on microchips, has, however, slowed down in recent years. This review takes a closer, critical look at how liquid phase chromatography has been implemented in miniaturized formats over the past several years, what is important...

  18. Undergraduate Separations Utilizing Flash Chromatography

    Science.gov (United States)

    Horowitz, G.

    2000-02-01

    This article describes the procedures used to carry out four flash chromatography experiments: the isolation of the carotenes, chlorophylls and xanthophylls from a spinach extract; the separation of ß-carotene from tetraphenyl cyclopentadienone; the isolation of (+) and (-) carvone from caraway and spearmint oil; and the purification of benzil from benzoin. Apparatus used is nonbreakable, easy to use, and inexpensive.

  19. Fault diagnosis of induction motors

    CERN Document Server

    Faiz, Jawad; Joksimović, Gojko

    2017-01-01

    This book is a comprehensive, structural approach to fault diagnosis strategy. The different fault types, signal processing techniques, and loss characterisation are addressed in the book. This is essential reading for work with induction motors for transportation and energy.

  20. Thin-Layer and Paper Chromatography.

    Science.gov (United States)

    Sherma, Joseph; Fried, Bernard

    1984-01-01

    Reviews literature on chromatography examining: books, reviews, student experiments; chromatographic systems, techniques, apparatus; detecting and identification of separated zones; preparative chromatography and radiochromatography; and applications related to specific materials (such as acids, alcohols, amino acids, antibiotics, enzymes, dyes,…

  1. Chromatography: Are We Getting It Right?

    Science.gov (United States)

    Maitland, Pamela D.; Maitland, David P.

    2002-01-01

    Explains the basics of chromatography which is used to demonstrate the separation of plant photosynthetic pigments. Reports the results of an evaluative study that explored textbook errors in explaining how chromatography works. (Contains 13 references.) (Author/YDS)

  2. Comparative determination of phenytoin by spectrophotometry, gas chromatography, liquid chromatography, enzyme immunoassay, and radioimmunoassay

    International Nuclear Information System (INIS)

    Castro, A.; Ibanez, J.; DiCesare, J.L.; Adams, R.F.; Malkus, H.

    1978-01-01

    Sera from patients being treated with phenytoin were analyzed for the drug by spectrophotometry, gas chromatography, radioimmunoasay, enzyme immunoassay, and liquid chromatography. The assay values obtained were intercompared statistically. Enzyme immunoassay and liquid chromatography appear to be attractive alternatives to the more traditional methods of spectrophotometry and gas chromatography. Our radioimmunoassay data correlated poorly with results by the four other methods

  3. Hypnosis for induction of labour.

    Science.gov (United States)

    Nishi, Daisuke; Shirakawa, Miyako N; Ota, Erika; Hanada, Nobutsugu; Mori, Rintaro

    2014-08-14

    Induction of labour using pharmacological and mechanical methods can increase complications. Complementary and alternative medicine methods including hypnosis may have the potential to provide a safe alternative option for the induction of labour. However, the effectiveness of hypnosis for inducing labour has not yet been fully evaluated. To assess the effect of hypnosis for induction of labour compared with no intervention or any other interventions. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 January 2014), handsearched relevant conference proceedings, contacted key personnel and organisations in the field for published and unpublished references. All published and unpublished randomised controlled trials (RCTs) and cluster-RCTs of acceptable quality comparing hypnosis with no intervention or any other interventions, in which the primary outcome is to assess whether labour was induced. Two review authors assessed the one trial report that was identified (but was subsequently excluded). No RCTs or cluster-RCTs were identified from the search strategy. There was no evidence available from RCTs to assess the effect of hypnosis for induction of labour. Evidence from RCTs is required to evaluate the effectiveness and safety of this intervention for labour induction. As hypnosis may delay standard care (in case standard care is withheld during hypnosis), its use in induction of labour should be considered on a case-by-case basis.Future RCTs are required to examine the effectiveness and safety of hypnotic relaxation for induction of labour among pregnant women who have anxiety above a certain level. The length and timing of the intervention, as well as the staff training required, should be taken into consideration. Moreover, the views and experiences of women and staff should also be included in future RCTs.

  4. Lipidomics by Supercritical Fluid Chromatography

    Directory of Open Access Journals (Sweden)

    Laurent Laboureur

    2015-06-01

    Full Text Available This review enlightens the role of supercritical fluid chromatography (SFC in the field of lipid analysis. SFC has been popular in the late 1980s and 1990s before almost disappearing due to the commercial success of liquid chromatography (LC. It is only 20 years later that a regain of interest appeared when new commercial instruments were introduced. As SFC is fully compatible with the injection of extracts in pure organic solvent, this technique is perfectly suitable for lipid analysis and can be coupled with either highly universal (UV or evaporative light scattering or highly specific (mass spectrometry detection methods. A short history of the use of supercritical fluids as mobile phase for the separation oflipids will be introduced first. Then, the advantages and drawbacks of SFC are discussed for each class of lipids (fatty acyls, glycerolipids, glycerophospholipids, sphingolipids, sterols, prenols, polyketides defined by the LIPID MAPS consortium.

  5. Lipidomics by Supercritical Fluid Chromatography

    Science.gov (United States)

    Laboureur, Laurent; Ollero, Mario; Touboul, David

    2015-01-01

    This review enlightens the role of supercritical fluid chromatography (SFC) in the field of lipid analysis. SFC has been popular in the late 1980s and 1990s before almost disappearing due to the commercial success of liquid chromatography (LC). It is only 20 years later that a regain of interest appeared when new commercial instruments were introduced. As SFC is fully compatible with the injection of extracts in pure organic solvent, this technique is perfectly suitable for lipid analysis and can be coupled with either highly universal (UV or evaporative light scattering) or highly specific (mass spectrometry) detection methods. A short history of the use of supercritical fluids as mobile phase for the separation oflipids will be introduced first. Then, the advantages and drawbacks of SFC are discussed for each class of lipids (fatty acyls, glycerolipids, glycerophospholipids, sphingolipids, sterols, prenols, polyketides) defined by the LIPID MAPS consortium. PMID:26090714

  6. Induction interview form in EDH

    CERN Multimedia

    Information technology Department, AIS (Administrative Information Services) Group,

    2007-01-01

    As part of the efforts to rationalise administrative procedures, the IT and HR Departments have developed a new EDH form for induction interviews, which can be accessed using the link below. In accordance with Administrative Circular No. 2 ('Recruitment, Appointment and possible developments regarding the contractual position of Staff Members', Rev. 3), the work and training objectives to be achieved during the probation period shall be specified in writing to all new staff members during an induction interview. The interview shall take place between the new staff member and his supervisor within six weeks of him taking up his duties at the latest. https://edh.cern.ch/Document/MAPS/Induction (or from the EDH desktop, by clicking on 'Other Tasks' and going to the 'HR & Training' heading) Please note that this form is to be used exclusively for new staff members. A separate EDH form will be developed for fellows. Information technology Department, AIS (Administrative Information Services) Group Human...

  7. Induction interview form in EDH

    CERN Document Server

    Information technology Department, AIS (Administrative Information Services) Group

    2007-01-01

    As part of the efforts to rationalise administrative procedures, the IT and HR Departments have developed a new EDH form for induction interviews, which can be accessed using the link below. In accordance with Administrative Circular No. 2 ('Recruitment, Appointment and possible developments regarding the contractual position of Staff Members', Rev. 3), the work and training objectives to be achieved during the probation period shall be specified in writing to all new staff members during an induction interview. The interview shall take place between the new staff member and his supervisor within six weeks of his taking up his duties at the latest. https://edh.cern.ch/Document/MAPS/Induction1) (or from the EDH desktop, by clicking on 'Other Tasks' and going to the 'HR & Training' heading) Please note that this form is to be used exclusively for new staff members. A separate EDH form will be developed for fellows.Information technology Department, AIS (Administrative Information Services) Group Human Re...

  8. Road infrastructure and demand induction

    DEFF Research Database (Denmark)

    Nielsen, Thomas Alexander Sick; Hovgesen, Henrik Harder; Lahrmann, Harry

    2006-01-01

    a long screenline is used to measure the development in aggregate demand in selected corridors. The paper analyses demand induction by establishing time series of aggregate demand that is compared with the national traffic index. Significant trend breaks in the association between aggregate demand...... in the corridors and the national index, following the opening of motorways or bridges, indicates demand induction by infrastructure expansion in a number of instances. Lack of significant trend breaks following opening year is found in peripheral areas where major population centres are missing. This indicates...... the necessity of some latent demand within suitable travel range for new infrastructure elements to produce significant amounts of induced demand. Estimates of demand induction as a percentage of the realised demand five years after opening are between 10% and 67% for new motorway sections depending...

  9. Harmonic modeling of induction motors

    Energy Technology Data Exchange (ETDEWEB)

    Pedra, J.; Sainz, L.; Corcoles, F. [Department of Electrical Engineering, ETSEIB-UPC, Av. Diagonal 647, 08028 Barcelona (Spain)

    2006-07-15

    The paper proposes an induction motor model for the study of harmonic load flow in balanced and unbalanced conditions. The parameters of this model are obtained from motor manufacturer data and the positive- and negative-sequence equivalent circuits of the single- and double-cage models. An approximate harmonic model based on motor manufacturer data only is also proposed. In addition, the paper includes manufacturer data and the calculated parameters of 36 induction motors of different rated powers. This database is used to analyze the proposed models. (author)

  10. Induction linacs and pulsed power

    International Nuclear Information System (INIS)

    Caporaso, G.J.

    1995-01-01

    Progress in electronic power conversion technology is making possible a new class of induction linacs that can operate at extremely high repetition rates. Advances in insulator technology, pulse forming line design and switching may also lead to a new type of high current accelerator with accelerating gradients at least an order of magnitude greater than those attainable today. The evolution of the induction accelerator pulsed power system will be discussed along with some details of these emerging technologies which are at the frontiers of accelerator technology

  11. Timing of induction of labor.

    Science.gov (United States)

    Bacak, Stephen J; Olson-Chen, Courtney; Pressman, Eva

    2015-10-01

    Determining the optimal timing for induction of labor is critical in minimizing the risks to maternal and fetal health. While data are available to guide us in some clinical situations, such as hypertension and diabetes, many gaps in knowledge still exist in others, including cholestasis of pregnancy, fetal anomalies, and placental abruption. This review of the currently available literature assesses the risks and benefits of preterm and early term induction in a wide variety of maternal and fetal conditions. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Immune chromatography: a quantitative radioimmunological assay

    International Nuclear Information System (INIS)

    Davis, J.W.; Demetriades, M.; Bowen, J.M.

    1984-01-01

    Immune chromatography, a radioimmunological binding assay, employs paper chromatography to separate immune complexes from free antigen and antibodies. During chromatography free antigen and antibodies become distributed throughout the paper, while immune complexes remain near the bottoms of the strips. The chromatographic differences can be made quantitative by using either iodinated antigens or antibodies. Under these conditions nanogram quantities of antigen can be detected or antibodies in sera diluted several 1000-fold. The immune chromatography assay can also be performed as an indirect assay, since the paper strips are cut from nitrocellulose paper. In this case the immune components are absorbed by the paper during chromatography. Antigen is then detected with an iodinated second antibody. The indirect immune chromatography assay is particularly useful for identifying different sera that react with the same antigen. Reaction with the first serum before chromatography reduces the amount of antigen available to the second serum following chromatography. In addition to characterizing the immune chromatography procedure, we discuss the possible applications of chromatography assays for the quantitation of other types of molecular binding interactions. (Auth.)

  13. Inductive acquisition of expert knowledge

    Energy Technology Data Exchange (ETDEWEB)

    Muggleton, S.H.

    1986-01-01

    Expert systems divide neatly into two categories: those in which (1) the expert decisions result in changes to some external environment (control systems), and (2) the expert decisions merely seek to describe the environment (classification systems). Both the explanation of computer-based reasoning and the bottleneck (Feigenbaum, 1979) of knowledge acquisition are major issues in expert-systems research. The author contributed to these areas of research in two ways: 1. He implemented an expert-system shell, the Mugol environment, which facilitates knowledge acquisition by inductive inference and provides automatic explanation of run-time reasoning on demand. RuleMaster, a commercial version of this environment, was used to advantage industrially in the construction and testing of two large classification systems. 2. He investigated a new techniques called 'sequence induction' that can be used in construction of control systems. Sequence induction is based on theoretical work in grammatical learning. He improved existing grammatical learning algorithms as well as suggesting and theoretically characterizing new ones. These algorithms were successfully applied to acquisition of knowledge for a diverse set of control systems, including inductive construction of robot plans and chess end-gam strategies.

  14. Phonotactics in inductive logic programming

    NARCIS (Netherlands)

    Nerbonne, J.; Konstantopoulos, S.; Klopotek, M.A.; Wierzchon, S.T.; Trojanowski, K.

    2004-01-01

    We examine the results of applying inductive logic programming (ILP) to a relatively simple linguistic task, that of recognizing monosyllables in one language. ILP is suited to linguistic problems given linguists' preference for formulating their theories in discrete rules, and because of ILP's

  15. Inductive logic on conceptual spaces

    NARCIS (Netherlands)

    Sznajder, Marta

    2017-01-01

    This thesis investigates the question of how conceptual frameworks influence inductive reasoning. A conceptual framework is a collection of concepts used for a particular purpose; we can think of it as a semantic environment in which observations, or evidence, are recorded, and beliefs are formed

  16. Teaching Inductive Reasoning with Puzzles

    Science.gov (United States)

    Wanko, Jeffrey J.

    2017-01-01

    Working with language-independent logic structures can help students develop both inductive and deductive reasoning skills. The Japanese publisher Nikoli (with resources available both in print and online) produces a treasure trove of language-independent logic puzzles. The Nikoli print resources are mostly in Japanese, creating the extra…

  17. Ion mobility: its role in plasma chromatography

    International Nuclear Information System (INIS)

    Mason, E.A.

    1984-01-01

    This paper is a review of the basic physical theory underlying plasma chromatography. Essentially, plasma chromatography simply measures ion mobility. The new feature of plasma chromatography, as compared to aqueous electrophoresis, is the existence of a highly-developed and accurate body of theory that connects gaseous ion mobility and diffusion to the ion molecule interactions in the drift tube. Attention is restricted to phenomena occurring in the drift tube portion of the apparatus

  18. Characterisation of uremic "Middle molecular"fractions by gas chromatography mass spectrometry, isotachophoresis, and liquid chromatography

    NARCIS (Netherlands)

    Schoots, A.C.; Mikkers, F.E.P.; Claessens, H.A.; Smet, de R.; Landschoot, van N.; Ringoir, S.M.G.

    1982-01-01

    Uremic ultrafiltrates (and normal serum, for comparison) were fractionated by means of gel filtration. The collected fractions were further investigated by combined analytical techniques: "high- performance" liquid chromatography, gas chromatography, mass spectrometry, and isotachophoresis.

  19. Arsenic speciation using high performance liquid chromatography-inductively coupled plasma-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Bass, D.A.; Yaeger, J.S.; Crain, J.S.; Kiely, J.T.; Parish, K.J.; Gowdy, M.J. [Argonne National Lab., IL (United States); Mohrman, G.B. [Rocky Mountain Arsenal, Commerce City, CO (United States)

    1995-08-01

    A method has been developed by Argonne National Laboratory to identify and quantify As(III), As(V), and organoarsenic compounds in environmental samples. A arsenic species were separated by reversed-phase, ion-pairing, HPLC using a microbore Inertsil-ODS{trademark} column. Only 1 {micro}L of sample was injected on the column, and the mobile phase flow rates were typically on the order of 40 {micro}L/min. The HPLC mobile phase was a mixture of methanol and tetrabutylammonium hydroxide (TBAH), and the column effluent was introduced into an ICP-mass spectrometer using direct injection nebulization. Detection limits of less than 1 pg As (as injected on the column) were easily obtained for each arsenic species. The effect of changes in mobile phase composition and ICP-MS conditions will be described, as well as quality control measures, e.g., the use of surrogates, internal standards, and matrix spikes. Precision and accuracy information will be presented from the analysis of aqueous standards and soil extracts that were spiked with arsenic oxide [As(III)], sodium arsenate [As(V)], dimethylarsinic acid (DMAA), or chlorovinyl arsenious acid (CVAA). The authors believe that these data demonstrate the utility of this technique for the sensitive determination of arsenic species present in water or soil.

  20. RNase-assisted RNA chromatography

    Science.gov (United States)

    Michlewski, Gracjan; Cáceres, Javier F.

    2010-01-01

    RNA chromatography combined with mass spectrometry represents a widely used experimental approach to identify RNA-binding proteins that recognize specific RNA targets. An important drawback of most of these protocols is the high background due to direct or indirect nonspecific binding of cellular proteins to the beads. In many cases this can hamper the detection of individual proteins due to their low levels and/or comigration with contaminating proteins. Increasing the salt concentration during washing steps can reduce background, but at the cost of using less physiological salt concentrations and the likely loss of important RNA-binding proteins that are less stringently bound to a given RNA, as well as the disassembly of protein or ribonucleoprotein complexes. Here, we describe an improved RNA chromatography method that relies on the use of a cocktail of RNases in the elution step. This results in the release of proteins specifically associated with the RNA ligand and almost complete elimination of background noise, allowing a more sensitive and thorough detection of RNA-binding proteins recognizing a specific RNA transcript. PMID:20571124

  1. Induction generator-induction motor wind-powered pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, M.S.; Lyra, R.O.C.; Silva, S.R. [CPDEE - UFMG, Belo Horizonte (Brazil)

    1997-12-31

    The energy storage matter plays an important role in wind-electric conversion systems for isolated applications. Having that in mind, two different approaches can be basically considered: either the immediate conversion of the generated electric energy, as in a water pumping system or electric energy storage for later use, as in a battery charging system. Due to some features such as no need of an external reactive power source and, sometimes, a gearbox, permanent-magnet synchronous generators have been broadly used in low rated power isolated systems. Despite that, system performance can be affected when the generator is feeding an inductive load (e.g., an induction motor) under variable-speed-variable-frequency operational conditions. Since there is no effective flux control, motor overload may occur at high wind speeds. Thus, good system performance can be obtained through additional control devices which may increase system cost. Although being rugged and cheap, induction machines always work as a reactive power drain; therefore, they demand an external reactive power source. Considering that, reactive static compensators appear as an attractive alternative to the cost x performance problem. In addition to that, different control strategies can be used so that system performance can be improved.

  2. Titrated Misoprostol Versus Dinoprostone for Labor Induction

    African Journals Online (AJOL)

    Aim: This study designed to compare titrated misoprostol regarding its safety and efficacy with dinoprostone for induction of labor. ... Statistical analysis done using Student's t-test for quantitative data and ..... induction: A pilot study. Rev Bras ...

  3. Scalable conditional induction variables (CIV) analysis

    KAUST Repository

    Oancea, Cosmin E.; Rauchwerger, Lawrence

    2015-01-01

    challenges to automatic parallelization. Because the complexity of such induction variables is often due to their conditional evaluation across the iteration space of loops we name them Conditional Induction Variables (CIV). This paper presents a flow

  4. Development of induction cells at CAEP

    International Nuclear Information System (INIS)

    Wang Huacen; Zhang Kaizhi; Cheng Nian'an; Zhang Wenwei; Lai Qinggui; Wen Long; Zhang Linwen; Deng Jianjun; Ding Bonan

    2002-01-01

    The effects to develop induction cells for induction linac and radiography at CAEP are introduced and reviewed in this paper. During the past two decades, several kinds of cells have been designed and tested, and some of them have been used for construction of induction linac, such as Dragon-1 and 12 MeV, and a Synthetic Test Stand (STS) for comprehensive linac technology study. The structure, test results and performance in the induction linac of these cells are given

  5. The induction on a continuous variable

    International Nuclear Information System (INIS)

    Zhang Jingzhong.

    1989-06-01

    Mathematical induction is a useful tool. But it could be used to prove only the proposition with form P(n) for the natural number n. Could the natural number n be replaced by a continuous variable x? Yes, and then we have the continuous induction. The continuous induction is very easy to grasp by the students who have learned mathematical induction. And it can be used to prove many basic propositions in the elementary calculus. (author)

  6. Application of gas chromatography in hydrogen isotope separation

    International Nuclear Information System (INIS)

    Ye Xiaoqiu; Sang Ge; Peng Lixia; Xue Yan; Cao Wei

    2008-01-01

    The principle of gas chromatographic separation of hydrogen isotopes was briefly introduced. The main technology and their development of separating hydrogen isotopes, including elution chromatography, hydrogen-displacement chromatography, self-displacement chromatography and frontal chromatography were discussed in detail. The prospect of hydrogen isotope separation by gas chromatography was presented. (authors)

  7. Induction Motors by Electric Measurements

    Directory of Open Access Journals (Sweden)

    Andrzej M. Trzynadlowski

    1999-01-01

    Full Text Available The paper gives an overview of the issues and means of detection of mechanical abnormalities in induction motors by electric measurements. If undetected and untreated, the worn or damaged bearings, rotor imbalance and eccentricity, broken bars of the rotor cage, and torsional and lateral vibration lead to roughly a half of all failures of induction motor drives. The detection of abnormalities is based on the fact that they cause periodic disturbance of motor variables, such as the speed, torque, current, and magnetic flux. Thus, spectral analysis of those or related quantities may yield a warning about an incipient failure of the drive system. Although the traditional non-invasive diagnostics has mostly been based on the signature analysis of the stator current, other media can also be employed. In particular, the partial instantaneous input power is shown, theoretically and experimentally, to offer distinct advantages under noisy operating conditions. Use of torque and flux estimates is also discussed.

  8. Review of induction linac studies

    International Nuclear Information System (INIS)

    Keefe, Denis

    1984-01-01

    The major emphasis of the U.S. program in Heavy Ion Fusion Accelerator Research is on developing and understanding induction-linac systems that employ multiple beams of high-current heavy ions. The culmination of the plan lies in building the High Temperature Experiment (HTE) which will involve an ion induction linac to deliver multiple high current beams, that can be focussed and overlapped on a two-millimeter diameter spot. A sequence of three major experimental activities are as follows. In the Single-Beam Transport Experiment (SBTE), the stability or otherwise transport of a high-current Cs +1 beam over a long distance is tested. In the Multiple-Beam Experiment (MBE), the experiment is designed to simulate on a small scale as many as possible of the features to be encountered in the HTE. (Mori, K.)

  9. Online Monitoring of Induction Motors

    Energy Technology Data Exchange (ETDEWEB)

    McJunkin, Timothy R. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Agarwal, Vivek [Idaho National Lab. (INL), Idaho Falls, ID (United States); Lybeck, Nancy Jean [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-01-01

    The online monitoring of active components project, under the Advanced Instrumentation, Information, and Control Technologies Pathway of the Light Water Reactor Sustainability Program, researched diagnostic and prognostic models for alternating current induction motors (IM). Idaho National Laboratory (INL) worked with the Electric Power Research Institute (EPRI) to augment and revise the fault signatures previously implemented in the Asset Fault Signature Database of EPRI’s Fleet Wide Prognostic and Health Management (FW PHM) Suite software. Induction Motor diagnostic models were researched using the experimental data collected by Idaho State University. Prognostic models were explored in the set of literature and through a limited experiment with 40HP to seek the Remaining Useful Life Database of the FW PHM Suite.

  10. Mutation induction by heavy ions

    Science.gov (United States)

    Kiefer, J.; Stoll, U.; Schneider, E.

    1994-10-01

    Mutation induction by heavy ions is compared in yeast and mammalian cells. Since mutants can only be recovered in survivors the influence of inactivation cross sections has to be taken into account. It is shown that both the size of the sensitive cellular site as well as track structure play an important role. Another parameter which influences the probability of mutation induction is repair: Contrary to naive assumptions primary radiation damage does not directly lead to mutations but requires modification to reconstitute the genetic machinery so that mutants can survive. The molecular structure of mutations was analyzed after exposure to deuterons by amplification with the aid of polymerase chain reaction. The results-although preliminary-demonstrate that even with densely ionizing particles a large fraction does not carry big deletions which suggests that point mutations may also be induced by heavy ions.

  11. Structured Statistical Models of Inductive Reasoning

    Science.gov (United States)

    Kemp, Charles; Tenenbaum, Joshua B.

    2009-01-01

    Everyday inductive inferences are often guided by rich background knowledge. Formal models of induction should aim to incorporate this knowledge and should explain how different kinds of knowledge lead to the distinctive patterns of reasoning found in different inductive contexts. This article presents a Bayesian framework that attempts to meet…

  12. Sensorless control of induction machine

    OpenAIRE

    Kılıç, Bahadır; Kilic, Bahadir

    2004-01-01

    AC drives based on fully digital control have reached the status of a maturing technology in a broad range of applications ranging from the low cost to high performance systems. Continuing research has concentrated on the removal of the sensors measuring the mechanical coordinates (e.g. tachogenerators, encoders) while maintaining the cost and performance of the control system. Speed estimation is an issue of particular interest with induction motor electrical drives as the rotor speed is gen...

  13. Inductive shearing of drilling pipe

    Science.gov (United States)

    Ludtka, Gerard M.; Wilgen, John; Kisner, Roger; Mcintyre, Timothy

    2016-04-19

    Induction shearing may be used to cut a drillpipe at an undersea well. Electromagnetic rings may be built into a blow-out preventer (BOP) at the seafloor. The electromagnetic rings create a magnetic field through the drillpipe and may transfer sufficient energy to change the state of the metal drillpipe to shear the drillpipe. After shearing the drillpipe, the drillpipe may be sealed to prevent further leakage of well contents.

  14. The law of electromagnetic induction

    Directory of Open Access Journals (Sweden)

    V.J. Kutkovetskyy

    2014-09-01

    Full Text Available Mathematical models of the electromagnetic induction law which do not take into account Faraday’s restrictions are not in full accordance with the physical phenomenon and so they are not laws. Their incomplete correspondence with real devices results in such "paradoxes" as unlimited magnetic field of unipolar generators, infinite sizes of inductors for DC and AC machines modeled, and so on.

  15. Segmented rail linear induction motor

    Science.gov (United States)

    Cowan, Jr., Maynard; Marder, Barry M.

    1996-01-01

    A segmented rail linear induction motor has a segmented rail consisting of a plurality of nonferrous electrically conductive segments aligned along a guideway. The motor further includes a carriage including at least one pair of opposed coils fastened to the carriage for moving the carriage. A power source applies an electric current to the coils to induce currents in the conductive surfaces to repel the coils from adjacent edges of the conductive surfaces.

  16. Blackout cloth for dormancy induction

    Science.gov (United States)

    Tom Jopson

    2007-01-01

    The use of blackout cloth to create long night photoperiods for the induction of dormancy in certain conifer species has been an established practice for a long time. Its use was suggested by Tinus and McDonald (1979) as an effective technique, and the practice has been commonly used in Canadian forest nurseries for a number of years. Cal-Forest Nursery installed its...

  17. Inductive, Analogical, and Communicative Generalization

    Directory of Open Access Journals (Sweden)

    Adri Smaling

    2003-03-01

    Full Text Available Three forms of inductive generalization - statistical generalization, variation-based generalization and theory-carried generalization - are insufficient concerning case-to-case generalization, which is a form of analogical generalization. The quality of case-to-case generalization needs to be reinforced by setting up explicit analogical argumentation. To evaluate analogical argumentation six criteria are discussed. Good analogical reasoning is an indispensable support to forms of communicative generalization - receptive and responsive (participative generalization — as well as exemplary generalization.

  18. Induction

    International Nuclear Information System (INIS)

    Serment G, J.; Brena V, M.

    2000-01-01

    At the incidence on biological systems, the ionizing radiation can affect so much its structural components as the genetic material since in a direct form or by the free radicals produced mainly the water radiolysis via (indirect effect). The alpha particles produce a great quantity of leisures in sites very near of them, by consequence results in a major RDB frequency. For establish the influence that would be the leisures concentration (specifically RDB) it was decided to research what occur when is irradiated with high LET corpuscular radiation and major power of ionization using for this alpha particles of an Americium 241 source and Escherichia coli stubs with different defects in reparation genes, recombination and protection to the radiation damage. (Author)

  19. Thin-layer and paper chromatography

    International Nuclear Information System (INIS)

    Sherma, J.

    1986-01-01

    This selective review covers the literature of thin-layer chromatography (TLC) and paper chromatography (PC) cited in Chemical Abstracts from December 5, 1983, through November 25, 1985, and Analytical Abstracts from November 1983 to November 1985. Also researched directly were the following important journals publishing papers on TLC and PC: the Journal of Chromatography (including its bibliography issues), Journal of High Resolution Chromatography and Chromatography Communications, Journal of Chromatographic Science, Chromatographia, Analytical Chemistry, JAOAC, and the special TLC issues of the Journal of Liquid Chromatography. Many of the inherent advantages of TLC that are obvious to workers familiar with high performance, quantitative theory and practice still are not appreciated adequately by the majority of people using chromatography. These include unrestricted access to the separation process; introducing magnetic, thermal, electrical, and other physical forces to improve resolution; high sample throughput; truly multidimensional separations; and the use of controlled multiple gradients. Many advantages of TLC relative to column chromatography were discussed in the Introductions to our 1982 and 1984 reviews of TLC in this Journal. No complete commercial robotics system specifically for TLC has been developed, but all necessary modules are available for such a system. The combination of robotics, with the continued development of theory, practice, and instrumentation will lead eventually to TLC systems that are unrivaled for speed, versatility, accuracy, precision, and sensitivity. 573 references

  20. Dielectrokinetic chromatography and devices thereof

    Science.gov (United States)

    Chirica, Gabriela S; Fiechtner, Gregory J; Singh, Anup K

    2014-04-22

    Disclosed herein are methods and devices for dielectrokinetic chromatography. As disclosed, the devices comprise microchannels having at least one perturber which produces a non-uniformity in a field spanning the width of the microchannel. The interaction of the field non-uniformity with a perturber produces a secondary flow which competes with a primary flow. By decreasing the size of the perturber the secondary flow becomes significant for particles/analytes in the nanometer-size range. Depending on the nature of a particle/analyte present in the fluid and its interaction with the primary flow and the secondary flow, the analyte may be retained or redirected. The composition of the primary flow can be varied to affect the magnitude of primary and/or secondary flows on the particles/analytes and thereby separate and concentrate it from other particles/analytes.

  1. Detection in superheated water chromatography

    International Nuclear Information System (INIS)

    Chienthavorn, O.

    1999-11-01

    Superheated water has been used successfully as an eluent in liquid chromatography and has been coupled to various modes of detection, ultraviolet (UV), fluorescence, and nuclear magnetic resonance spectroscopy (NMR) and mass spectrometry (MS). A number of compounds were examined on poly(styrene-divinylbenzene) (PS-DVB), polybutadiene (PBD), and octadecylsilyl bonded silica (ODS) column with isothermal and temperature programmes. The PS-DVB column was mostly used throughout the project as it was the most stable. Not only pure water could serve as superheated water mobile phase; inorganic buffered water and ion-pairing reagent with a concentration of 1-3 mM of the buffer and reagent were also exploited. It was shown that the pH could be controlled during the separation without salt precipitation and the separations followed a conventional reversed-phase HPLC method. Results from fluorescence detection showed good separation of a series of vitamins, such as pyridoxine, riboflavin, thiamine, and some analgesics. The relationship of riboflavin using the detection was linear and the detection limit was seven times higher than that of a conventional method. Simultaneous separation and identification using superheated water chromatography-NMR was demonstrated. With using a stop flow method, NMR spectra of model drugs, namely barbiturates, paracetamol, caffeine and phenacetin were obtained and the results agreed with reference spectra, confirming a perfect separation. A demonstration to obtain COSY spectrum of salicylamide was also performed. The method was expanded to the coupling of superheated water LC to NMR-MS. Results from the hyphenated detection method showed that deuteration and degradation happened in the superheated water conditions. The methyl group hydrogens of pyrimidine ring of sulfonamide and thiamine were exchanged with deuterium. Thiamine was decomposed to 4-methyl-5-thiazoleethanol and both were deuterated under the conditions. (author)

  2. Induction of differentiation of murine embryonal carcinoma cells by ouabain

    International Nuclear Information System (INIS)

    Zimmerman, B.T.

    1986-01-01

    Embryonal carcinoma (EC) cells can be induced to differentiate by ouabain at concentrations which inhibit Na + , K + -ATPase activity as measured by inhibition of 86 Rb + uptake. Since the pharmacologic action of ouabain is thought to be specific, the authors investigated the role of Na + , K + -ATPase inhibition and specific metabolic consequences of this inhibition in the induction of EC differentiation, and explored whether this might be a common mode of action for a variety of structurally diverse inducers. The Na + , K + -ATPase maintains ionic gradients in cells. However, results of studies utilizing specific ionophores, channel blockers, and media deficient in specific components failed to demonstrate a consistent role for ion flux or concentration in the differentiation process. The Na + , K + -ATPase is a major consumer of ATP. They therefore examined the effect of Na + , K + -ATPase inhibition on the adenylate energy charge as measured by high performance liquid chromatography of adenylate nucleotides. Ouabain was found to significantly decrease the energy charge in sensitive cells suggesting a role for suppression of ATP turnover is triggering differentiation. However, direct inhibition of glycolysis also induced differentiation without decreasing the energy charge, suggesting that reduction of the energy charge is not a common mechanism for induction of differentiation of EC

  3. Lessons for Inductive Germline Determination

    Science.gov (United States)

    Seervai, Riyad N.H.; Wessel, Gary M.

    2015-01-01

    SUMMARY Formation of the germline in an embryo marks a fresh round of reproductive potential, yet the developmental stage and location within the embryo where the primordial germ cells (PGCs) form differs wildly among species. In most animals, the germline is formed either by an inherited mechanism, in which maternal provisions within the oocyte drive localized germ-cell fate once acquired in the embryo, or an inductive mechanism that involves signaling between cells that directs germ-cell fate. The inherited mechanism has been widely studied in model organisms such as Drosophila melanogaster, Caenorhabditis elegans, Xenopus laevis, and Danio rerio. Given the rapid generation time and the effective adaptation for laboratory research of these organisms, it is not coincidental that research on these organisms has led the field in elucidating mechanisms for germline specification. The inductive mechanism, however, is less well understood and is studied primarily in the mouse (Mus musculus). In this review, we compare and contrast these two fundamental mechanisms for germline determination, beginning with the key molecular determinants that play a role in the formation of germ cells across all animal taxa. We next explore the current understanding of the inductive mechanism of germ-cell determination in mice, and evaluate the hypotheses for selective pressures on these contrasting mechanisms. We then discuss the hypothesis that the transition between these determination mechanisms, which has happened many times in phylogeny, is more of a continuum than a binary change. Finally, we propose an analogy between germline determination and sex determination in vertebrates—two of the milestones of reproduction and development—in which animals use contrasting strategies to activate similar pathways. PMID:23450642

  4. Induction linacs as radiation processors

    International Nuclear Information System (INIS)

    Birx, D.L.

    1986-01-01

    Experiments at the Lawrence Livermore National Laboratory (LLNL), University of California, in conjunction with the University of California at Davis have shown induction linear accelerators (linacs) to be suitable for radiation processing of food. Here we describe how it might be possible to optimize this technology developded for the Department of Defense to serve in radiation processing. The possible advantages of accelerator-produced radiation over the use of radioisotopes include a tailor-made energy spectrum that can provide much deeper penetration and thereby better dose uniformity

  5. Induction Hardening of External Gear

    Science.gov (United States)

    Bukanin, V. A.; Ivanov, A. N.; Zenkov, A. E.; Vologdin, V. V.; Vologdin, V. V., Jr.

    2018-03-01

    Problems and solution of gear induction hardening are described. Main attention is paid to the parameters of heating and cooling systems. ELTA 7.0 program has been used to obtain the required electrical parameters of inductor, power sources, resonant circuits, as well as to choose the quenching media. Comparison of experimental and calculated results of investigation is provided. In order to compare advantages and disadvantages of single- and dual-frequency heating processes, many variants of these technologies were simulated. The predicted structure and hardness of steel gears are obtained by use of the ELTA data base taken into account the Continuous Cooling Transformation diagrams.

  6. Elementary induction on abstract structures

    CERN Document Server

    Moschovakis, Yiannis N

    2008-01-01

    Hailed by the Bulletin of the American Mathematical Society as ""easy to use and a pleasure to read,"" this research monograph is recommended for students and professionals interested in model theory and definability theory. The sole prerequisite is a familiarity with the basics of logic, model theory, and set theory.The author, Professor of Mathematics at UCLA and Emeritus Professor of Mathematics,University of Athens, Greece, begins with a focus on the theory of inductive and hyperelementary sets. Subsequent chapters advance to acceptable structures and countable acceptable structures, concl

  7. Analytical chromatography. Methods, instrumentation and applications

    International Nuclear Information System (INIS)

    Yashin, Ya I; Yashin, A Ya

    2006-01-01

    The state-of-the-art and the prospects in the development of main methods of analytical chromatography, viz., gas, high performance liquid and ion chromatographic techniques, are characterised. Achievements of the past 10-15 years in the theory and general methodology of chromatography and also in the development of new sorbents, columns and chromatographic instruments are outlined. The use of chromatography in the environmental control, biology, medicine, pharmaceutics, and also for monitoring the quality of foodstuffs and products of chemical, petrochemical and gas industries, etc. is considered.

  8. Supersonic induction plasma jet modeling

    International Nuclear Information System (INIS)

    Selezneva, S.E.; Boulos, M.I.

    2001-01-01

    Numerical simulations have been applied to study the argon plasma flow downstream of the induction plasma torch. It is shown that by means of the convergent-divergent nozzle adjustment and chamber pressure reduction, a supersonic plasma jet can be obtained. We investigate the supersonic and a more traditional subsonic plasma jets impinging onto a normal substrate. Comparing to the subsonic jet, the supersonic one is narrower and much faster. Near-substrate velocity and temperature boundary layers are thinner, so the heat flux near the stagnation point is higher in the supersonic jet. The supersonic plasma jet is characterized by the electron overpopulation and the domination of the recombination over the dissociation, resulting into the heating of the electron gas. Because of these processes, the supersonic induction plasma permits to separate spatially different functions (dissociation and ionization, transport and deposition) and to optimize each of them. The considered configuration can be advantageous in some industrial applications, such as plasma-assisted chemical vapor deposition of diamond and polymer-like films and in plasma spraying of nanoscaled powders

  9. Plasma internal inductance dynamics in a tokamak

    International Nuclear Information System (INIS)

    Romero, J.A.

    2010-01-01

    A lumped parameter model for tokamak plasma current and inductance time evolution as a function of plasma resistance, non-inductive current drive sources and boundary voltage or poloidal field coil current drive is presented. The model includes a novel formulation leading to exact equations for internal inductance and plasma current dynamics. Having in mind its application in a tokamak inductive control system, the model is expressed in state space form, the preferred choice for the design of control systems using modern control systems theory. The choice of system states allows many interesting physical quantities such as plasma current, inductance, magnetic energy, and resistive and inductive fluxes be made available as output equations. The model is derived from energy conservation theorem, and flux balance theorems, together with a first order approximation for flux diffusion dynamics. The validity of this approximation has been checked using experimental data from JET showing an excellent agreement.

  10. Radiochemical purity determination by paper chromatography 2

    International Nuclear Information System (INIS)

    1975-01-01

    The standard relates to the determination of radiochemical impurities in labelled compounds using paper chromatography. The basic terms are given as is the description of procedure and evaluation of chromatograms. (E.S.)

  11. Ion Chromatography Applications in Wastewater Analysis

    Directory of Open Access Journals (Sweden)

    Rajmund Michalski

    2018-02-01

    Full Text Available Wastewater analysis is an important area in analytical and environmental chemistry. It can be performed with both the classic wet methods and instrumental techniques. The development of new methods, and modification of the existing ones, constitute a major task for researchers. Ion chromatography plays a predominant role in ion determinations with the instrumental methods. It offers several advantages over the conventional methods, such as simultaneous determinations of alkali and alkaline earth cations and ammonia. Ammonium ions cannot be determined by spectroscopic methods. Ion chromatography has been accepted world-wide as a reference method for analyzing anions and cations in water and wastewater due to the fact that it enables the replacement of several individual wet chemistry methods for common ions with one instrumental technique. The following article describes the principles of ion chromatography, such as stationary phases, eluents, detectors, and sample preparation methods. Moreover, the applications of ion chromatography in wastewater analyses and international standards are presented.

  12. Gradient High Performance Liquid Chromatography Method ...

    African Journals Online (AJOL)

    Purpose: To develop a gradient high performance liquid chromatography (HPLC) method for the simultaneous determination of phenylephrine (PHE) and ibuprofen (IBU) in solid ..... nimesulide, phenylephrine. Hydrochloride, chlorpheniramine maleate and caffeine anhydrous in pharmaceutical dosage form. Acta Pol.

  13. Experimental demonstration of the KEK induction synchrotron

    International Nuclear Information System (INIS)

    Takayama, Ken; Torikai, Kota; Shimosaki, Yoshito; Kono, Tadaaki; Iwashita, Taiki; Arakida, Yoshio; Nakamura, Eiji; Shirakata, Masashi; Sueno, Takeshi; Wake, Masayoshi; Otsuka, Kazunori

    2007-01-01

    Recent progress in the KEK induction synchrotron is presented. In the recent experiment, by using a newly developed induction acceleration system instead of radio-wave acceleration devices, a single proton bunch injected from the 500 MeV Booster ring and captured by the barrier bucket created by the induction step-voltages was accelerated to 6 GeV in the KEK proton synchrotron

  14. UHPLC: The Greening Face of Liquid Chromatography

    OpenAIRE

    Cielecka-Piontek, Judyta; Zalewski, Przemys?aw; Jeli?ska, Anna; Garbacki, Piotr

    2013-01-01

    Pharmaceutical analysis based on chromatographic separation is an important part of studies aimed at developing routine quality analysis of drugs. High-performance liquid chromatography (HPLC) is one of the main analytical techniques recommended for drug analysis. Although it meets many criteria vital for analysis, it is time-consuming and uses a relatively high amount of organic solvents compared to other analytical techniques. Recently, Ultra-high-performance liquid chromatography (UHPLC) h...

  15. Selection of imprinted nanoparticles by affinity chromatography.

    Science.gov (United States)

    Guerreiro, António R; Chianella, Iva; Piletska, Elena; Whitcombe, Michael J; Piletsky, Sergey A

    2009-04-15

    Soluble molecularly imprinted nanoparticles were synthesised via iniferter initiated polymerisation and separated by size via gel permeation chromatography. Subsequent fractionation of these particles by affinity chromatography allowed the separation of high affinity fractions from the mixture of nanoparticles. Fractions selected this way possess affinity similar to that of natural antibodies (K(d) 6.6x10(-8)) M and were also able to discriminate between related functional analogues of the template.

  16. Induction immunosuppressive therapies in renal transplantation.

    Science.gov (United States)

    Gabardi, Steven; Martin, Spencer T; Roberts, Keri L; Grafals, Monica

    2011-02-01

    Induction immunosuppressive therapies for patients undergoing renal transplantation are reviewed. The goal of induction therapy is to prevent acute rejection during the early posttransplantation period by providing a high degree of immunosuppression at the time of transplantation. Induction therapy is often considered essential to optimize outcomes, particularly in patients at high risk for poor short-term outcomes. All of the induction immunosuppressive agents currently used are biological agents and are either monoclonal (muromonab-CD3, daclizumab, basiliximab, alemtuzumab) or polyclonal (antithymocyte globulin [equine] or antithymocyte globulin [rabbit]) antibodies. Although antithymocyte globulin (rabbit) is not labeled for induction therapy, it is used for this purpose more than any other agent. Basiliximab is not considered as potent an immunosuppressive agent but has a much more favorable adverse-effect profile compared with antithymocyte globulin (rabbit) and is most commonly used in patients at low risk for acute rejection. Rituximab is being studied for use as induction therapy but to date has not demonstrated any significant benefits over placebo. While head-to-head data are available comparing most induction agents, the final decision on the most appropriate induction therapy for a transplant recipient is highly dependent on preexisting medical conditions, donor characteristics, and the maintenance immunosuppressive regimen to be used. No standard induction immunosuppressive regimen exists for patients undergoing renal transplantation. Antithymocyte globulin (rabbit) is the most commonly used agent, whereas basiliximab appears safer. The choice of regimen depends on the preferences of clinicians and institutions.

  17. Compound induction electric rotating machine

    Energy Technology Data Exchange (ETDEWEB)

    Decesare, D

    1987-07-28

    The present invention generally relates to dynamo-electric machines cabable of operating in a generator mode or in a motor mode and more specifically, to increased efficiency compound interaction AC and/or DC dynamo-electric machines. This patent describes such a machine having a distributed armature winding in a cylindrical rotor wound to form axial and substantially radial winding portions and including permanent and/or electromagnets to couple magnetic flux into the peripheral or circumferential surface of the rotor, and to provide interaction between a magnetic field formed beyond the rotor axial surfaces and the rotor to thereby enhance the total induction of flux into the rotor for improved, more efficient operation. 28 figs.,

  18. Review of induction linac studies

    International Nuclear Information System (INIS)

    Keefe, D.

    1984-01-01

    The three major experimental activities are as follows: (1) The Single-Beam Transport Experiment (SBTE): A quadrupole transport system consisting of 5 matching lenses and 41 identical F-D lens pairs to test the stability, or otherwise, of transport of a high-current Cs +1 beam over a long distance; (2) The Multiple-Beam Experiment (MBE): An arrangement of long-pulse induction accelerating units between which are placed multiple-beam focussing arrays to transport 16 independent beams threading the same accelerating structure. The experiment is designed to simulate on a small scale as many as possible of the features to be encountered in the HTE; and (3) The High Temperature Experiment

  19. Induction brazing of complex joints

    DEFF Research Database (Denmark)

    Henningsen, Poul; Zhang, Wenqi; Bay, Niels

    2003-01-01

    , or if the hottest area is located outside the joint interface, a number of defects may appear: the braze metal may flow away from the joint, the flux may burn off, poor binding of the braze metal may appear or the braze metal may be overheated. Joint geometry as well as electro-magnetic properties of the work piece...... presents a combined numerical and experimental method for fast determination of appropriate coil geometry and position in induction brazing tube-to-plate joints of different ratios between tube and plate thickness and different combinations of the materials stainless steel, brass and copper. The method has...... proven to give successful results in brazing tube-plate joints of copper-brass, copper-stainless steel, stainless steel-brass, and stainless steel-stainless steel....

  20. BACKWARD INDUCTION: MERITS AND FLAWS

    Directory of Open Access Journals (Sweden)

    Kamiński Marek M.

    2017-06-01

    Full Text Available Backward induction (BI was one of the earliest methods developed for solving finite sequential games with perfect information. It proved to be especially useful in the context of Tom Schelling’s ideas of credible versus incredible threats. BI can be also extended to solve complex games that include an infinite number of actions or an infinite number of periods. However, some more complex empirical or experimental predictions remain dramatically at odds with theoretical predictions obtained by BI. The primary example of such a troublesome game is Centipede. The problems appear in other long games with sufficiently complex structure. BI also shares the problems of subgame perfect equilibrium and fails to eliminate certain unreasonable Nash equilibria.

  1. Induction Magnetometers – Design Peculiarities

    Directory of Open Access Journals (Sweden)

    Valeriy KOREPANOV

    2010-09-01

    Full Text Available Induction or search-coil magnetometers (IM are widely used in many branches of science and industry. The frequency range and dynamic range of IMs are probably the widest of all existing magnetometers: they are used for the measurement of magnetic field variations in the frequency band from ~10-4 till ~106 Hz with the intensities from fractions of femtotesla till tens of tesla. This explains the permanent interest to IM design and the attempts to construct the IMs with best possible parameters. The present paper deals with the peculiarities of IM design. An attempt to re-establish the correctness of priorities in the field is made and the approaches to the IM optimization and their quality estimation are described.

  2. Selective Induction of Optical Magnetism.

    Science.gov (United States)

    Manna, Uttam; Lee, Jung-Hoon; Deng, Tian-Song; Parker, John; Shepherd, Nolan; Weizmann, Yossi; Scherer, Norbert F

    2017-12-13

    An extension of the Maxwell-Faraday law of electromagnetic induction to optical frequencies requires spatially appropriate materials and optical beams to create resonances and excitations with curl. Here we employ cylindrical vector beams with azimuthal polarization to create electric fields that selectively drive magnetic responses in dielectric core-metal nanoparticle "satellite" nanostructures. These optical frequency magnetic resonances are induced in materials that do not possess spin or orbital angular momentum. Multipole expansion analysis of the scattered fields obtained from electrodynamics simulations show that the excitation with azimuthally polarized beams selectively enhances magnetic vs electric dipole resonances by nearly 100-fold in experiments. Multipolar resonances (e.g., quadrupole and octupole) are enhanced 5-fold by focused azimuthally versus linearly polarized beams. We also selectively excite electric multipolar resonances in the same identical nanostructures with radially polarized light. This work opens new opportunities for spectroscopic investigation and control of "dark modes", Fano resonances, and magnetic modes in nanomaterials and engineered metamaterials.

  3. Phenotypical difference in deamination of cytarabine is not evident in induction therapy for acute myeloid leukemia

    DEFF Research Database (Denmark)

    Krogh-Madsen, Mikkel; Hansen, Steen Honore'; Jensen, Morten Krogh

    2013-01-01

    Objective To investigate the uracil arabinoside/cytarabine (Ara-U/Ara-C) ratios with the lower dose in adult acute myeloid leukaemia (AML) induction therapy (100 mg/m2 Ara-C) where no enzyme saturation is expected. Methods A precise and robust high-performance liquid chromatography (HPLC) method...... for simultaneous determination of Ara-C and its main inactive metabolite Ara-U in human plasma was developed and validated. Nineteen patients with acute myeloid leukaemia were treated with Ara-C in a dose of 100 mg/m2 together with daunorubicin and etoposide. Plasma concentrations were used to construct...

  4. Large scale chromatographic separations using continuous displacement chromatography (CDC)

    International Nuclear Information System (INIS)

    Taniguchi, V.T.; Doty, A.W.; Byers, C.H.

    1988-01-01

    A process for large scale chromatographic separations using a continuous chromatography technique is described. The process combines the advantages of large scale batch fixed column displacement chromatography with conventional analytical or elution continuous annular chromatography (CAC) to enable large scale displacement chromatography to be performed on a continuous basis (CDC). Such large scale, continuous displacement chromatography separations have not been reported in the literature. The process is demonstrated with the ion exchange separation of a binary lanthanide (Nd/Pr) mixture. The process is, however, applicable to any displacement chromatography separation that can be performed using conventional batch, fixed column chromatography

  5. Airtight miniaturized chromatography: a safer method for radiopharmaceutical quality control

    International Nuclear Information System (INIS)

    Coupal, J.J.; Shih, W.J.; Ryo, U.Y.

    1988-01-01

    Miniaturized chromatography is widely used for quality control of radiopharmaceuticals. Recently, published chromatography procedures have illustrated or described chromatography chambers open to the air in use, suggesting that volatile toxic mobile phases are harmless to people in the vicinity. The authors describe the results of their search for an inexpensive closed chromatography chamber that can be used to derive safely the benefits from conventional miniaturized chromatography

  6. Stationary phases for superheated water chromatography

    International Nuclear Information System (INIS)

    Saha, Shikha

    2002-01-01

    This project focused on the comparison of conventional liquid chromatography and superheated water chromatography. It examined the differences in efficiency and retention of a range of different stationary phases. Alkyl aryl ketones and eight aromatic compounds were separated on PBD-zirconia, Xterra RP 18, Luna C 18 (2) and Oasis HLB columns using conventional LC and superheated water chromatography system. The retention indices were determined in the different eluents. On changing the organic component of the eluent from methanol to acetonitrile to superheated water considerable improvements were found in the peak shapes and column efficiencies on the PBD-zirconia and Oasis HLB columns. PS-DVB, PBD-zirconia and Xterra RP 18 columns have been used in efficiency studies. It was found that simply elevating the column temperature did not increase the efficiency of a separation in superheated water chromatography. The efficiency depended on flow rate, injection volume and also mobile phase preheating system. Although high efficiencies were not achieved with superheated water on PS-DVB and Xterra RP 18 columns, a higher efficiency was achieved on a PBD-zirconia column with superheated water than with 25-35% ACN at room temperature. The proposed theoretical increases in u opt were measured on three columns using superheated water as the mobile phase. The application of the superheated water chromatographic method to the separation of the pungent constituents of ginger by superheated water chromatography-NMR coupling system was studied. The coupling of superheated water chromatography using deuterium oxide to NMR spectroscopy for the separation of dry ginger extract was successful, although the NMR sensitivity in on-line mode coupling system was low. However, four compounds were identified in the ginger extract by stop-flow mode on superheated water chromatography-UV-NMR detection system. (author)

  7. The Tower of Hanoi and Inductive Logic

    Science.gov (United States)

    Merrotsy, Peter

    2015-01-01

    In the "Australian Curriculum," the concept of mathematical induction is first met in the senior secondary subject Specialist Mathematics. This article details an example, the Tower of Hanoi problem, which provides an enactive introduction to the inductive process before moving to more abstract and cognitively demanding representations.…

  8. Eisenstein integrals and induction of relations

    NARCIS (Netherlands)

    Ban, E.P. van den

    2004-01-01

    A survey of joint work with Henrik Schlichtkrull on the induction of certain relations among (partial) Eisenstein integrals for the minimal principal series of a reductive symmetric space is given. The application of this principle of induction to the proof of the Fourier inversion formula in

  9. A Framework of Mathematics Inductive Reasoning

    Science.gov (United States)

    Christou, Constantinos; Papageorgiou, Eleni

    2007-01-01

    Based on a synthesis of the literature in inductive reasoning, a framework for prescribing and assessing mathematics inductive reasoning of primary school students was formulated and validated. The major constructs incorporated in this framework were students' cognitive abilities of finding similarities and/or dissimilarities among attributes and…

  10. Inductive Reasoning About Effectful Data Types

    DEFF Research Database (Denmark)

    Filinski, Andrzej; Støvring, Kristian

    2007-01-01

    We present a pair of reasoning principles, definition and proof by rigid induction, which can be seen as proper generalizations of lazy-datatype induction to monadic effects other than partiality. We further show how these principles can be integrated into logical-relations arguments, and obtain...

  11. A Philosophical Treatise of Universal Induction

    Directory of Open Access Journals (Sweden)

    Samuel Rathmanner

    2011-06-01

    Full Text Available Understanding inductive reasoning is a problem that has engaged mankind for thousands of years. This problem is relevant to a wide range of fields and is integral to the philosophy of science. It has been tackled by many great minds ranging from philosophers to scientists to mathematicians, and more recently computer scientists. In this article we argue the case for Solomonoff Induction, a formal inductive framework which combines algorithmic information theory with the Bayesian framework. Although it achieves excellent theoretical results and is based on solid philosophical foundations, the requisite technical knowledge necessary for understanding this framework has caused it to remain largely unknown and unappreciated in the wider scientific community. The main contribution of this article is to convey Solomonoff induction and its related concepts in a generally accessible form with the aim of bridging this current technical gap. In the process we examine the major historical contributions that have led to the formulation of Solomonoff Induction as well as criticisms of Solomonoff and induction in general. In particular we examine how Solomonoff induction addresses many issues that have plagued other inductive systems, such as the black ravens paradox and the confirmation problem, and compare this approach with other recent approaches.

  12. Production of Highly Charged Pharmaceutical Aerosols Using a New Aerosol Induction Charger.

    Science.gov (United States)

    Golshahi, Laleh; Longest, P Worth; Holbrook, Landon; Snead, Jessica; Hindle, Michael

    2015-09-01

    Properly charged particles can be used for effective lung targeting of pharmaceutical aerosols. The objective of this study was to characterize the performance of a new induction charger that operates with a mesh nebulizer for the production of highly charged submicrometer aerosols to bypass the mouth-throat and deliver clinically relevant doses of medications to the lungs. Variables of interest included combinations of model drug (albuterol sulfate) and charging excipient (NaCl) as well as strength of the charging field (1-5 kV/cm). Aerosol charge and size were measured using a modified electrical low pressure impactor system combined with high performance liquid chromatography. At the approximate mass median aerodynamic diameter (MMAD) of the aerosol (~0.4 μm), the induction charge on the particles was an order of magnitude above the field and diffusion charge limit. The nebulization rate was 439.3 ± 42.9 μl/min, which with a 0.1% w/v solution delivered 419.5 ± 34.2 μg of medication per minute. A new correlation was developed to predict particle charge produced by the induction charger. The combination of the aerosol induction charger and predictive correlations will allow for the practical generation and control of charged submicrometer aerosols for targeting deposition within the lungs.

  13. Intrinsic magnetic torque at low magnetic induction

    International Nuclear Information System (INIS)

    Doria, M.M.; Oliveira, I.G. de.

    1993-01-01

    Using anisotropic London theory the intrinsic magnetic torque for extreme type II uniaxial superconductors for any value of the magnetic induction is obtained. It is considered the vortex lines straight and take into account the contribution of the supercurrents flowing inside the vortex core within the London theory. It is shown that the interline and intra line free energies give opposite torque contributions, the first drives the magnetic induction parallel to the superconductor's axis of symmetry and the second orthogonal to it. At high magnetic induction torque expression obtained generalizes V. Kogan's formula since it has no free parameters other than the anisotropy γ = m 1 /m 3 and the Ginzburg-Landau parameter κ. At low magnetic induction it is proposed a way to observe vortex chains effects in the total torque based on the fact that London theory is linear and the energy to make a single vortex line in space is independent of the magnetic induction. (author)

  14. Modeling and analysis with induction generators

    CERN Document Server

    Simões, M Godoy

    2014-01-01

    ForewordPrefaceAcknowledgmentsAuthorsPrinciples of Alternative Sources of Energy and Electric GenerationScope of This ChapterLegal DefinitionsPrinciples of Electrical ConversionBasic Definitions of Electrical PowerCharacteristics of Primary SourcesCharacteristics of Remote Industrial, Commercial, and Residential Sites and Rural EnergySelection of the Electric GeneratorInterfacing Primary Source, Generator, and LoadExample of a Simple Integrated Generating and Energy-Storing SystemSolved ProblemsSuggested ProblemsReferencesSteady-State Model of Induction GeneratorsScope of This ChapterInterconnection and Disconnection of the Electric Distribution NetworkRobustness of Induction GeneratorsClassical Steady-State Representation of the Asynchronous MachineGenerated PowerInduced TorqueRepresentation of Induction Generator LossesMeasurement of Induction Generator ParametersBlocked Rotor Test (s = 1)No-Load Test (s = 0)Features of Induction Machines Working as Generators Interconnected to the Distribution NetworkHigh-...

  15. Induction accelerator test module for HIF

    International Nuclear Information System (INIS)

    Faltens, A.

    1991-04-01

    An induction linac test module suitable for investigating the drive requirements and the longitudinal coupling impedance of a high-power ion induction linac has been constructed by the Heavy Ion Fusion (HIF) group at LBL. The induction linac heavy ion driver for inertial confinement fusion (ICF) as presently envisioned uses multiple parallel beams which are transported in separate focusing channels but accelerated together in the induction modules. The resulting induction modules consequently have large beam apertures-1--2 meters in diameter- and correspondingly large outside diameters. The module geometry is related to a low-frequency ''gap capacity'' and high-frequency structural resonances, which are affected by the magnetic core loading and the module pulser impedance. A description of the test module and preliminary results are presented. 3 figs

  16. On line protection systems for induction motors

    International Nuclear Information System (INIS)

    Colak, I.; Celik, H.; Sefa, I.; Demirbas, S.

    2005-01-01

    Protection of induction motors is very important since they are widely used in industry for many applications due to their high robustness, reliability, low cost and maintenance, high efficiency and long service life. So, protecting these motors is crucial for operations. This paper presents a combined protection approach for induction motors. To achieve this, the electrical values of the induction motor were measured with sensitivity ±1% through a data acquisition card and processed with software developed in Visual C++. An on line protection system for induction motors was achieved easily and effectively. The experimental results have shown that the induction motor was protected against the possible problems faced during the operation. The software developed for this protection provides flexible and reliable media for operators and their motors. It is expected that the motor protection achieved in this study might be faster than the classical techniques and also may be applied to larger motors easily after small modifications of the software

  17. Reasoning about modular datatypes with Mendler induction

    Directory of Open Access Journals (Sweden)

    Paolo Torrini

    2015-09-01

    Full Text Available In functional programming, datatypes a la carte provide a convenient modular representation of recursive datatypes, based on their initial algebra semantics. Unfortunately it is highly challenging to implement this technique in proof assistants that are based on type theory, like Coq. The reason is that it involves type definitions, such as those of type-level fixpoint operators, that are not strictly positive. The known work-around of impredicative encodings is problematic, insofar as it impedes conventional inductive reasoning. Weak induction principles can be used instead, but they considerably complicate proofs. This paper proposes a novel and simpler technique to reason inductively about impredicative encodings, based on Mendler-style induction. This technique involves dispensing with dependent induction, ensuring that datatypes can be lifted to predicates and relying on relational formulations. A case study on proving subject reduction for structural operational semantics illustrates that the approach enables modular proofs, and that these proofs are essentially similar to conventional ones.

  18. Laboratory and field based evaluation of chromatography ...

    Science.gov (United States)

    The Monitor for AeRosols and GAses in ambient air (MARGA) is an on-line ion-chromatography-based instrument designed for speciation of the inorganic gas and aerosol ammonium-nitrate-sulfate system. Previous work to characterize the performance of the MARGA has been primarily based on field comparison to other measurement methods to evaluate accuracy. While such studies are useful, the underlying reasons for disagreement among methods are not always clear. This study examines aspects of MARGA accuracy and precision specifically related to automated chromatography analysis. Using laboratory standards, analytical accuracy, precision, and method detection limits derived from the MARGA chromatography software are compared to an alternative software package (Chromeleon, Thermo Scientific Dionex). Field measurements are used to further evaluate instrument performance, including the MARGA’s use of an internal LiBr standard to control accuracy. Using gas/aerosol ratios and aerosol neutralization state as a case study, the impact of chromatography on measurement error is assessed. The new generation of on-line chromatography-based gas and particle measurement systems have many advantages, including simultaneous analysis of multiple pollutants. The Monitor for Aerosols and Gases in Ambient Air (MARGA) is such an instrument that is used in North America, Europe, and Asia for atmospheric process studies as well as routine monitoring. While the instrument has been evaluat

  19. Comprehensive two-dimensional liquid chromatography: Ion chromatography × reversed-phase liquid chromatography for separation of low-molar-mass organic acids

    NARCIS (Netherlands)

    Brudin, S.S.; Shellie, R.A.; Haddad, P.R.; Schoenmakers, P.J.

    2010-01-01

    In the work presented here a novel approach to comprehensive two-dimensional liquid chromatography is evaluated. Ion chromatography is chosen for the first-dimension separation and reversed-phase liquid chromatography is chosen for the second-dimension separation mode. The coupling of these modes is

  20. Graph-based inductive reasoning.

    Science.gov (United States)

    Boumans, Marcel

    2016-10-01

    This article discusses methods of inductive inferences that are methods of visualizations designed in such a way that the "eye" can be employed as a reliable tool for judgment. The term "eye" is used as a stand-in for visual cognition and perceptual processing. In this paper "meaningfulness" has a particular meaning, namely accuracy, which is closeness to truth. Accuracy consists of precision and unbiasedness. Precision is dealt with by statistical methods, but for unbiasedness one needs expert judgment. The common view at the beginning of the twentieth century was to make the most efficient use of this kind of judgment by representing the data in shapes and forms in such a way that the "eye" can function as a reliable judge to reduce bias. The need for judgment of the "eye" is even more necessary when the background conditions of the observations are heterogeneous. Statistical procedures require a certain minimal level of homogeneity, but the "eye" does not. The "eye" is an adequate tool for assessing topological similarities when, due to heterogeneity of the data, metric assessment is not possible. In fact, graphical assessments precedes measurement, or to put it more forcefully, the graphic method is a necessary prerequisite for measurement. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Ovulation induction: a mini review.

    Science.gov (United States)

    Messinis, Ioannis E

    2005-10-01

    Ovulation induction is the method for treating anovulatory infertility. For patients with hypogonadotrophic hypogonadism, the treatment involves administration of both FSH and LH, while HCG is injected for follicle rupture. Pulsatile GnRH has the same effectiveness as gonadotrophins and the advantage of the low multiple pregnancy rate. In polycystic ovary syndrome (PCOS), the first treatment choice is clomiphene citrate. With this drug, in properly selected patients, the cumulative pregnancy rate approaches that of normal women. Low-dose protocols of FSH are the second line of treatment, effective in inducing monofollicular development. Laparoscopic ovarian drilling can be an alternative but not as a first choice treatment in clomiphene-resistant patients. Other treatments, such as pulsatile GnRH and GnRH agonists, are hardly used today in PCOS. However, in obese women with PCOS, weight loss and exercise should be recommended as the first line of therapy. Newer agents including aromatase inhibitors and insulin sensitizers, although promising, need further evaluation.

  2. Diagonal chromatography to study plant protein modifications.

    Science.gov (United States)

    Walton, Alan; Tsiatsiani, Liana; Jacques, Silke; Stes, Elisabeth; Messens, Joris; Van Breusegem, Frank; Goormachtig, Sofie; Gevaert, Kris

    2016-08-01

    An interesting asset of diagonal chromatography, which we have introduced for contemporary proteome research, is its high versatility concerning proteomic applications. Indeed, the peptide modification or sorting step that is required between consecutive peptide separations can easily be altered and thereby allows for the enrichment of specific, though different types of peptides. Here, we focus on the application of diagonal chromatography for the study of modifications of plant proteins. In particular, we show how diagonal chromatography allows for studying proteins processed by proteases, protein ubiquitination, and the oxidation of protein-bound methionines. We discuss the actual sorting steps needed for each of these applications and the obtained results. This article is part of a Special Issue entitled: Plant Proteomics--a bridge between fundamental processes and crop production, edited by Dr. Hans-Peter Mock. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Inert carriers for column extraction chromatography

    International Nuclear Information System (INIS)

    Katykhin, G.S.

    1978-01-01

    Inert carriers used in column extraction chromatography are reviewed. Such carriers are devided into two large groups: hydrophilic carriers which possess high surface energy and are well wetted only with strongly polar liquids (kieselguhrs, silica gels, glasses, cellulose, Al 2 O 3 ) and water-repellent carriers which possess low surface energy and are well wetted with various organic solvents (polyethylene, polytetrafluorethylene polytrifluorochlorethylene). Properties of various carriers are presented: structure, chemical and radiation stability, adsorption properties, extracting agent capacity. The effect of structure and sizes of particles on the efficiency of chromatography columns is considered. Ways of immovable phase deposition on the carrier and the latter's regeneration. Peculiarities of column packing for preparative and continuous chromatography are discussed

  4. Liquid chromatography detection unit, system, and method

    Science.gov (United States)

    Derenzo, Stephen E.; Moses, William W.

    2015-10-27

    An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method of liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.

  5. Electrochemical Detectors in HPLC and Ion Chromatography.

    Science.gov (United States)

    Horvai, George; Pungor, ErnÕ

    1989-01-01

    Back in 1952, the renowned Polish electrochemist Wiktor Kemula introduced chromato-polarography, 1 i.e., polaro-graphic detection for liquid chromatography. This technique continued to develop slowly until the early 1970s (for a review see Reference 2) when modem high-performance liquid chromatography (HPLC) emerged. This new, highly efficient chromatographc method could only be. used with detectors ensuring low dispersion. It was not easy to modify the dropping mercury electrode cells to satisfy this requirement. However, at the same time, electroanalytical chemists, who already had much experience in using carbon-based electrodes for oxidative detection in flow analysis, put forward the idea of oxidative amperometric detection in liquid chromatography. 3,4 In this technique, solid or quasi-solid (paste) electrodes were used and this made possible the construction of miniaturized cells with just a few microliter volume.

  6. Linear Parameter Varying Control of Induction Motors

    DEFF Research Database (Denmark)

    Trangbæk, Klaus

    The subject of this thesis is the development of linear parameter varying (LPV) controllers and observers for control of induction motors. The induction motor is one of the most common machines in industrial applications. Being a highly nonlinear system, it poses challenging control problems...... for high performance applications. This thesis demonstrates how LPV control theory provides a systematic way to achieve good performance for these problems. The main contributions of this thesis are the application of the LPV control theory to induction motor control as well as various contributions...

  7. Inductive tuners for microwave driven discharge lamps

    Science.gov (United States)

    Simpson, James E.

    1999-01-01

    An RF powered electrodeless lamp utilizing an inductive tuner in the waveguide which couples the RF power to the lamp cavity, for reducing reflected RF power and causing the lamp to operate efficiently.

  8. New type of magnetohydrodynamic converters: induction devices

    International Nuclear Information System (INIS)

    Petit, J.-P.; Viton, Maurice.

    1977-01-01

    A new induction MHD accelerator, disc shaped, with controlled ionization, is presented. Associated with a light and powerful electric generator it could become a MHD aerodyne. Solutions for confining the plasma to the wall are indicated [fr

  9. Failed labor induction: toward an objective diagnosis.

    LENUS (Irish Health Repository)

    Rouse, Dwight J

    2011-02-01

    To evaluate maternal and perinatal outcomes in women undergoing labor induction with an unfavorable cervix according to duration of oxytocin administration in the latent phase of labor after ruptured membranes.

  10. Progress in antenna coupled kinetic inductance detectors

    NARCIS (Netherlands)

    Baryshev, A.; Baselmans, J.J.A.; Freni, A.; Gerini, G.; Hoevers, H.F.C.; Iacono, A.; Neto, A.

    2011-01-01

    This paper describes the combined Dutch efforts toward the development of large wideband focal plane array receivers based on kinetic inductance detectors (KIDs). Taking into account strict electromagnetic and detector sensitivity requirements for future ground and space based observatories, this

  11. Frequency characteristics of geomagnetic induction anomalies in ...

    Indian Academy of Sciences (India)

    P V Vijaya Kumar

    2017-10-07

    Oct 7, 2017 ... characteristics of electrical conductivity distribution are presented in the form of induction arrows. From ... High resistive block related to underplating mantle material has .... Recent seismic tomography studies indicate low.

  12. A Framework for Evaluating Induction into Teaching.

    Science.gov (United States)

    Schlechty, Phillip C.

    1985-01-01

    Indicators and characteristics of effective induction systems are described using efforts of the Charlotte-Mecklenburg Schools' Career Development Program as an example. Fundamental changes needed in the way teacher education is conceptualized by school personnel are discussed. (DF)

  13. Coreless Concept for High Gradient Induction Cell

    International Nuclear Information System (INIS)

    Krasnykh, Anatoly

    2008-01-01

    An induction linac cell for a high gradient is discussed. The proposed solid state coreless approach for the induction linac topology (SLIM(reg s ign)) is based on nanosecond mode operation. This mode may have an acceleration gradient comparable with gradients of rf- accelerator structures. The discussed induction system has the high electric efficiency. The key elements are a solid state semiconductor switch and a high electric density dielectric with a thin section length. The energy in the induction system is storied in the magnetic field. The nanosecond current break-up produces the high voltage. The induced voltage is used for acceleration. This manner of an operation allows the use of low voltage elements in the booster part and achieves a high accelerating gradient. The proposed topology was tested in POP (proof of principle) experiments

  14. Combined Approach for Solving the Electromagnetic Induction ...

    African Journals Online (AJOL)

    Nafiisah

    boundary. For example, in electromagnetic induction imaging, it is the magnetic ... Applications of electromagnetic .... The first integral is referred to as a single layer potential and is continuous across ..... Scattering Theory, 2nd ed., Springer.

  15. Inductance position sensor for pneumatic cylinder

    Directory of Open Access Journals (Sweden)

    Pavel Ripka

    2018-04-01

    Full Text Available The position of the piston in pneumatic cylinder with aluminum wall can be measured by external inductance sensor without modifications of the aluminum piston and massive iron piston rod. For frequencies below 20 Hz the inductance is increasing with inserting rod due to the rod permeability. This mode has disadvantage of slow response to piston movement and also high temperature sensitivity. At the frequency of 45 Hz the inductance is position independent, as the permeability effect is compensated by the eddy current effect. At higher frequencies eddy current effects in the rod prevail, the inductance is decreasing with inserting rod. In this mode the sensitivity is smaller but the sensor response is fast and temperature stability is better. We show that FEM simulation of this sensor using measured material properties gives accurate results, which is important for the sensor optimization such as designing the winding geometry for the best linearity.

  16. Inductance position sensor for pneumatic cylinder

    Science.gov (United States)

    Ripka, Pavel; Chirtsov, Andrey; Mirzaei, Mehran; Vyhnanek, Jan

    2018-04-01

    The position of the piston in pneumatic cylinder with aluminum wall can be measured by external inductance sensor without modifications of the aluminum piston and massive iron piston rod. For frequencies below 20 Hz the inductance is increasing with inserting rod due to the rod permeability. This mode has disadvantage of slow response to piston movement and also high temperature sensitivity. At the frequency of 45 Hz the inductance is position independent, as the permeability effect is compensated by the eddy current effect. At higher frequencies eddy current effects in the rod prevail, the inductance is decreasing with inserting rod. In this mode the sensitivity is smaller but the sensor response is fast and temperature stability is better. We show that FEM simulation of this sensor using measured material properties gives accurate results, which is important for the sensor optimization such as designing the winding geometry for the best linearity.

  17. Induction generator models in dynamic simulation tools

    DEFF Research Database (Denmark)

    Knudsen, Hans; Akhmatov, Vladislav

    1999-01-01

    For AC network with large amount of induction generators (windmills) the paper demonstrates a significant discrepancy in the simulated voltage recovery after fault in weak networks when comparing dynamic and transient stability descriptions and the reasons of discrepancies are explained...

  18. Validated High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, rapid and sensitive high performance liquid chromatography (HPLC) method for the determination of cefadroxil monohydrate in human plasma. Methods: Schimadzu HPLC with LC solution software was used with Waters Spherisorb, C18 (5 μm, 150mm × 4.5mm) column. The mobile phase ...

  19. Electronic spectral detection in liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Biggs, Wilton R. [ChevronTexaco Chemical Co., P. O. Box 1627, Richmond, CA 94802 (United States); Fetzer, John C. [Fetzpahs Consulting, 1283 Santa Fe St., Hercules, CA 94547 (United States)

    2002-07-01

    The use of absorbance and fluorescence spectrometers as liquid chromatography detectors is described. These detectors offer sensitive detection that can also identify the peaks in a chromatogram. Many examples, mainly from the separation of polycyclic aromatic hydrocarbons, are given that show the selectivity and usefulness of these detectors. (orig.)

  20. Ionic liquid stationary phases for gas chromatography.

    Science.gov (United States)

    Poole, Colin F; Poole, Salwa K

    2011-04-01

    This article provides a summary of the development of ionic liquids as stationary phases for gas chromatography beginning with early work on packed columns that established details of the retention mechanism and established working methods to characterize selectivity differences compared with molecular stationary phases through the modern development of multi-centered cation and cross-linked ionic liquids for high-temperature applications in capillary gas chromatography. Since there are many reviews on ionic liquids dealing with all aspects of their chemical and physical properties, the emphasis in this article is placed on the role of gas chromatography played in the design of ionic liquids of low melting point, high thermal stability, high viscosity, and variable selectivity for separations. Ionic liquids provide unprecedented opportunities for extending the selectivity range and temperature-operating range of columns for gas chromatography, an area of separation science that has otherwise been almost stagnant for over a decade. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Gas chromatography at the Tritium Laboratory Karlsruhe

    International Nuclear Information System (INIS)

    Laesser, R.; Gruenhagen, S.

    2003-08-01

    Among the analytical techniques (mass spectrometry, laser Raman spectroscopy, gas chromatography, use of ionisation chambers) employed at the Tritium Laboratory Karlsruhe (TLK), gas chromatography plays a prominent role. The main reasons for that are the simplicity of the gas chromatographic separation process, the small space required for the equipment, the low investment costs in comparison to other methods, the robustness of the equipment, the simple and straightforward analysis and the fact that all gas species of interest (with the exception of water) can easily be detected by gas chromatographic means. The conventional gas chromatographs GC1 and GC2 used in the Tritium Measurement Techniques (TMT) System of the TLK and the gas chromatograph GC3 of the experiment CAPER are presented in detail, by discussing their flow diagrams, their major components, the chromatograms measured by means of various detectors, shortcomings and possible improvements. One of the main disadvantages of the conventional gas chromatography is the long retention times required for the analysis of hydrogen gas mixtures. To overcome this disadvantage, micro gas chromatography for hydrogen analysis was developed. Reduction of the retention times by one order of magnitude was achieved. (orig.)

  2. Instrument platforms for nano liquid chromatography

    Czech Academy of Sciences Publication Activity Database

    Šesták, Jozef; Moravcová, Dana; Kahle, Vladislav

    2015-01-01

    Roč. 1421, NOV (2015), s. 2-17 ISSN 0021-9673 R&D Projects: GA MV VG20112015021 Institutional support: RVO:68081715 Keywords : nano liquid chromatography * splitless gradient generation * nano LC platforms Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.926, year: 2015 http://hdl.handle.net/11104/0250900

  3. Instrument platforms for nano liquid chromatography.

    Science.gov (United States)

    Šesták, Jozef; Moravcová, Dana; Kahle, Vladislav

    2015-11-20

    The history of liquid chromatography started more than a century ago and miniaturization and automation are two leading trends in this field. Nanocolumn liquid chromatography (nano LC) and largely synonymous capillary liquid chromatography (capillary LC) are the most recent results of this process where miniaturization of column dimensions and sorbent particle size play crucial role. Very interesting results achieved in the research of extremely miniaturized LC columns at the end of the last century lacked distinctive raison d'être and only advances in mass spectrometry brought a real breakthrough. Configuration of nano LC-electrospray ionization mass spectrometry (LC-ESI-MS) has become a basic tool in bioanalytical chemistry, especially in proteomics. This review discusses and summarizes past and current trends in the realization of nano liquid chromatography (nano LC) platforms. Special attention is given to the mobile phase delivery under nanoflow rates (isocratic, gradient) and sample injection to the nanocolumn. Available detection techniques applied in nano LC separations are also briefly discussed. We followed up the key themes from the original scientific reports over gradual improvements up to the contemporary commercial solutions. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Ultra Performance Liquid Chromatography Tandem Mass ...

    African Journals Online (AJOL)

    NICOLAAS

    drugs alone.16. After a single oral dose of 120–800 mg of NTB in healthy sub- jects in a fasting state the peak plasma NTB concentration (tmax) was found to be 4–7 h, with a half-life of approximately 9–17 h.17 ... performance liquid chromatography mass spectrometry/mass .... to the likely biological plasma constituents.

  5. Analytical biotechnology: Capillary electrophoresis and chromatography

    International Nuclear Information System (INIS)

    Horvath, C.; Nikelly, J.G.

    1990-01-01

    The papers describe the separation, characterization, and equipment required for the electrophoresis or chromatography of cyclic nucleotides, pharmaceuticals, therapeutic proteins, recombinant DNA products, pheromones, peptides, and other biological materials. One paper, On-column radioisotope detection for capillary electrophoresis, has been indexed separately for inclusion on the data base

  6. Bibliography of extraction chromatography, ch. 15

    International Nuclear Information System (INIS)

    Eschrich, H.; Drent, W.

    1975-01-01

    A bibliography of reviews, books and publications dealing with laminar extraction chromatography is given. A tabular survey of experimental data on column extraction chromatographic investigations, stationary phases and support materials is presented. An author index and corporative author index are included. This bibliography refers to various publications relevant to nuclear interest

  7. Gas chromatography in blood carbon monoxide monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Drasche, H.; Funk, L.; Herbolsheimer, R.

    1975-05-01

    A description of a gas chromatography method for monitoring blood carboxyhaemoglobin (HbCO) levels in a very small quantity (100 mcl) of capillary blood: reagents and apparatus, procedures, calculation of results. To calculate HbCO content, an aliquot portion of water-diluted blood is saturated with CO; this saturation obviates the need to determine the haemoglobin or iron blood levels.

  8. Diagnostics of internal inductance in HT-7

    International Nuclear Information System (INIS)

    Zeng Li; Wan Baonian; Qian Jinping; Fan Hengyu

    2001-01-01

    Two arrays of Mirnov coils and a pair of concentric loops have been installed to superconducting tokamak HT-7. Software compensation and digital Fourier series expansion are the two techniques that have been applied successfully in measuring diamagnetic flux of concentric loops and internal inductance. The internal inductance of plasma l i , poloidal beta β p , Grad Shafranov parameter Λ, plasma minor radius α p and the center of the outermost magnetic flux surface Δ g are determined

  9. Resistorless Electronically Tunable Grounded Inductance Simulator Design

    OpenAIRE

    Herencsár, Norbert; Kartci, Aslihan

    2017-01-01

    A new realization of grounded lossless positive inductance simulator (PIS) using simple inverting voltage buffer and unity-gain current follower/inverter (CF±) is reported. Considering the input intrinsic resistance of CF± as useful active parameter, the proposed PIS can be considered as resistorless circuit and it only employs in total 16 Metal-Oxide-Semiconductor (MOS) transistors and a grounded capacitor. The resulting equivalent inductance value of the proposed simulator can be adjusted v...

  10. Digital inductive teaching method of strabismus

    OpenAIRE

    Zhao-Jiang Du; Peng Li; Li Wang

    2015-01-01

    AIM: To reform the traditional teaching modes of strabismus by using digital induction to enhance logic in teaching process.METHODS: The study was performed in the group of 20 eight-year program clinical undergraduates from the class of 2009 and 198 five-year program clinical undergraduates from the class of 2010. These students were divided into two groups receiving traditional and digital induction teaching over the same period respectively. After classes, questionnaire survey and classroom...

  11. Physic basis of electromagnetic induction low

    Directory of Open Access Journals (Sweden)

    V.J. Kutkovetskyy

    2015-03-01

    Full Text Available The statement on the macro level of EMF dependence on change in magnetic flux in time wrong reflects the physical phenomenon of electromagnetic induction low by Faraday, because EMF can be inducted if the magnetic flux of the circuit does not change. Changing magnetic flux of the circuit when the electromotive force arises is only a result of crossing the magnetic field lines by conductor and is an exception, which applies only to certain classes of electric machines.

  12. Influences of various factors on hairy root induction in Agastache foeniculum (Pursh Kuntze

    Directory of Open Access Journals (Sweden)

    Elnaz NOUROZI

    2016-04-01

    Full Text Available Agrobacterium rhizogenes is known as a natural tool of genetic engineering in many plant species. For the first time, hairy root induction in Agastache foeniculum using A. rhizogenes, rosmarinic acid content and the effect of different culture media and inoculation methods on hairy root growth rate were investigated. Hairy root culture of A. foeniculum was established by inoculation of the 1-month-old leaf explant with A4 strain of A. rhizogenes and the effectiveness of light – dark conditions and two inoculation methods (immersion and injection were tested. Furthermore, in immersion method, the effects of inoculation time (3, 5 and 7 min on root induction were investigated. In the second part of the study, the hairy root culture of A. foeniculum was studied using different basal culture media (MS, 1/2 MS and B5. Rosmarinic acid content in hairy roots and non- transformed roots was analyzed using high-performance liquid chromatography (HPLC. There was no significant difference between various inoculation methods in the ability of hairy roots induction. Observations showed that percentage of hairy root induction was higher when the explants were immersed for 5 min in bacterial suspension. Light conditions displayed the highest hairy root induction rates compared with dark condition. Various culture media are different in terms of types and amounts of nutrients and have influence on growth rate. The maximum growth rate (1.61 g fr wt/50 ml of hairy roots were obtained in 1/2 MS medium. Rosmarinic acid content in transformed roots (213.42 µg/g dry wt was significantly higher than non-transformed roots (52.28 µg/ g dry wt.

  13. Loading Effects on Resolution in Thin Layer Chromatography and ...

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 10; Issue 11. Loading Effects on Resolution in Thin Layer Chromatography and Paper Chromatography. K Girigowda V H Mulimani. Classroom Volume 10 Issue 11 November 2005 pp 79-84 ...

  14. Separation of Chloroplast Pigments Using Reverse Phase Chromatography.

    Science.gov (United States)

    Reese, R. Neil

    1997-01-01

    Presents a protocol that uses reverse phase chromatography for the separation of chloroplast pigments. Provides a simple and relatively safe procedure for use in teaching laboratories. Discusses pigment extraction, chromatography, results, and advantages of the process. (JRH)

  15. High Performance Liquid Chromatography Experiments to Undergraduate Laboratories

    Science.gov (United States)

    Kissinger, Peter T.; And Others

    1977-01-01

    Reviews the principles of liquid chromatography with electrochemical detection (LCEC), an analytical technique that incorporates the advantages of both liquids chromatography and electrochemistry. Also suggests laboratory experiments using this technique. (MLH)

  16. Development of a high performance liquid chromatography method ...

    African Journals Online (AJOL)

    Development of a high performance liquid chromatography method for simultaneous ... Purpose: To develop and validate a new low-cost high performance liquid chromatography (HPLC) method for ..... Several papers have reported the use of ...

  17. Cyclobutane-type pyrimidine photodimer formation and induction of ornithine decarboxylase in human skin fibroblasts after UV irradiation

    International Nuclear Information System (INIS)

    Niggli, H.J.; Roethlisberger, R.

    1988-01-01

    Cyclobutane-type pyrimidine photodimers as well as the induction of ornithine decarboxylase (ODC) may serve as biochemical markers of the mutagenic and carcinogenic effects of ultraviolet light (UV). For this reason, it is important to compare the formation of pyrimidine dimers with the induction of ODC in human skin fibroblasts after irradiation with UVC (200-290 nm) and UVB (290-320 nm). In our studies we determined cytosine-thymine (C-T) as well as thymine-thymine dimer yields (T-T) by high-pressure liquid chromatography in cultures of neonatal normal human foreskin-derived fibroblasts after irradiation with UVC and UVB light. It was found that the yield of dimerization and the ratio of T-T/C-T decreased from the UVC to the UVB region. Time-course studies of ODC-induction in the same cells indicated that the maximal activity after UVB irradiation was retarded compared to UVC exposure. For the UV-induced ODC-levels, however, no significant difference in maximal induction could be measured after UVC and UVB irradiation at fluences where comparable yields of thymine dimerization are produced. Similar ODC-maxima were obtained with strains from children, while cells from adults showed significantly less pronounced ODC induction, indicating that ODC-response decreases with age and may therefore be used as a marker of aging

  18. Optimizing separations in online comprehensive two‐dimensional liquid chromatography

    OpenAIRE

    Pirok, Bob W.J.; Gargano, Andrea F.G.; Schoenmakers, Peter J.

    2017-01-01

    Abstract Online comprehensive two‐dimensional liquid chromatography has become an attractive option for the analysis of complex nonvolatile samples found in various fields (e.g. environmental studies, food, life, and polymer sciences). Two‐dimensional liquid chromatography complements the highly popular hyphenated systems that combine liquid chromatography with mass spectrometry. Two‐dimensional liquid chromatography is also applied to the analysis of samples that are not compatible with mass...

  19. Comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones.

    Science.gov (United States)

    Carnes, Stephanie; O'Brien, Stacey; Szewczak, Angelica; Tremeau-Cayel, Lauriane; Rowe, Walter F; McCord, Bruce; Lurie, Ira S

    2017-09-01

    A comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones has been conducted. Nine different mixtures of bath salts were analyzed in this study. The three different chromatographic techniques were examined using a general set of controlled synthetic cathinones as well as a variety of other synthetic cathinones that exist as positional isomers. Overall 35 different synthetic cathinones were analyzed. A variety of column types and chromatographic modes were examined for developing each separation. For the ultra high performance supercritical fluid chromatography separations, analyses were performed using a series of Torus and Trefoil columns with either ammonium formate or ammonium hydroxide as additives, and methanol, ethanol or isopropanol organic solvents as modifiers. Ultra high performance liquid chromatographic separations were performed in both reversed phase and hydrophilic interaction chromatographic modes using SPP C18 and SPP HILIC columns. Gas chromatography separations were performed using an Elite-5MS capillary column. The orthogonality of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography was examined using principal component analysis. For the best overall separation of synthetic cathinones, the use of ultra high performance supercritical fluid chromatography in combination with gas chromatography is recommended. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. High perfomance liquid chromatography in pharmaceutical analyses.

    Science.gov (United States)

    Nikolin, Branko; Imamović, Belma; Medanhodzić-Vuk, Saira; Sober, Miroslav

    2004-05-01

    In testing the pre-sale procedure the marketing of drugs and their control in the last ten years, high performance liquid chromatography replaced numerous spectroscopic methods and gas chromatography in the quantitative and qualitative analysis. In the first period of HPLC application it was thought that it would become a complementary method of gas chromatography, however, today it has nearly completely replaced gas chromatography in pharmaceutical analysis. The application of the liquid mobile phase with the possibility of transformation of mobilized polarity during chromatography and all other modifications of mobile phase depending upon the characteristics of substance which are being tested, is a great advantage in the process of separation in comparison to other methods. The greater choice of stationary phase is the next factor which enables realization of good separation. The separation line is connected to specific and sensitive detector systems, spectrafluorimeter, diode detector, electrochemical detector as other hyphernated systems HPLC-MS and HPLC-NMR, are the basic elements on which is based such wide and effective application of the HPLC method. The purpose high performance liquid chromatography (HPLC) analysis of any drugs is to confirm the identity of a drug and provide quantitative results and also to monitor the progress of the therapy of a disease.1) Measuring presented on the Fig. 1. is chromatogram obtained for the plasma of depressed patients 12 h before oral administration of dexamethasone. It may also be used to further our understanding of the normal and disease process in the human body trough biomedical and therapeutically research during investigation before of the drugs registration. The analyses of drugs and metabolites in biological fluids, particularly plasma, serum or urine is one of the most demanding but one of the most common uses of high performance of liquid chromatography. Blood, plasma or serum contains numerous endogenous

  1. Advances in chromatography of the rare earth elements (review)

    International Nuclear Information System (INIS)

    Oguma, Koichi; Kuroda, Rokuro; Shimizu, Tsuneo.

    1995-01-01

    A review is presented which covers liquid chromatography, gas chromatography, and related techniques. This article intends to describe the chromatographic methods playing an important role in the separation of the rare earth elements. Special attention is paid to the usefulness of various types of liquid chromatography which enable the complete mutual separation of the rare earth elements. Applications are also discussed. (author) 161 refs

  2. Applications of liquid phase chromatographies for the analysis of streams arising at the back end of nuclear fuel cycle

    International Nuclear Information System (INIS)

    Deshingkar, D.S.; Yalmali, Vrunda S.; Wattal, P.K.

    2000-06-01

    India has opted for a closed fuel cycle comprising of reprocessing and recycling technology. The back end of such nuclear fuel cycle involves the reprocessing of spent nuclear fuels for recovery of plutonium and depleted uranium by Purex technology. Wastes arising from the reprocessing plant are classified as high, intermediate and low level wastes (HLW, ILW, LLW). HLW is mixture of over 50 elements present in different chemical forms. The accurate analyses of dissolver solution and HLW are the most challenging but essential tasks for reprocessing plant operations and also for further development of treatment methods. Inductively coupled plasma - atomic emission spectroscopy and atomic absorption spectroscopy techniques are suitable for analysis of metallic anions. Ion chromatography has proven capability to analyse number of cations or anions at ppm or even ppb level in single run. The report reviews the literature regarding the title subject. To assess the technical feasibility of ion chromatography for waste analysis, a simulated PHWR-HLW analogue was prepared. The PHWR-HLW analogue and ground water samples were analysed on DIONEX-DX 500 and Metrohm IC. Results obtained clearly demonstrated the usefulness of ion chromatography as vital analytical tool. HLW and other process or waste streams arising at the back end of nuclear fuel cycle can be analysed for alkali, alkaline earth, rare earth and transition metal cations and important anions. Use of fraction collector along with ion chromatography can enhance it's sensitivity to few Bq/ml for radioactive samples. (author)

  3. High performance liquid chromatography in pharmaceutical analyses

    Directory of Open Access Journals (Sweden)

    Branko Nikolin

    2004-05-01

    Full Text Available In testing the pre-sale procedure the marketing of drugs and their control in the last ten years, high performance liquid chromatographyreplaced numerous spectroscopic methods and gas chromatography in the quantitative and qualitative analysis. In the first period of HPLC application it was thought that it would become a complementary method of gas chromatography, however, today it has nearly completely replaced gas chromatography in pharmaceutical analysis. The application of the liquid mobile phase with the possibility of transformation of mobilized polarity during chromatography and all other modifications of mobile phase depending upon the characteristics of substance which are being tested, is a great advantage in the process of separation in comparison to other methods. The greater choice of stationary phase is the next factor which enables realization of good separation. The separation line is connected to specific and sensitive detector systems, spectrafluorimeter, diode detector, electrochemical detector as other hyphernated systems HPLC-MS and HPLC-NMR, are the basic elements on which is based such wide and effective application of the HPLC method. The purpose high performance liquid chromatography(HPLC analysis of any drugs is to confirm the identity of a drug and provide quantitative results and also to monitor the progress of the therapy of a disease.1 Measuring presented on the Fig. 1. is chromatogram obtained for the plasma of depressed patients 12 h before oral administration of dexamethasone. It may also be used to further our understanding of the normal and disease process in the human body trough biomedical and therapeutically research during investigation before of the drugs registration. The analyses of drugs and metabolites in biological fluids, particularly plasma, serum or urine is one of the most demanding but one of the most common uses of high performance of liquid chromatography. Blood, plasma or

  4. Application of forgetful analgesia induction in induction period in patients with obstructive jaundice

    Directory of Open Access Journals (Sweden)

    Wei DU

    2014-03-01

    Full Text Available Objective To observe the effect of forgetful analgesia induction and tracheal intubation on the hemodynamic changes in induction period in patients with obstructive jaundice, and explore a safe method for anesthesia induction and tracheal intubation. Methods Sixty patients with obstructive jaundice undergoing elective abdominal operation in General Hospital of PLA from February, 2013 to August, 2013 were involved in the present study. Participants included 36 male and 24 female patients, aging 19-65 years (mean 42±5 years, weighing 47-73 kg (mean 54±6 kg, with ASA Ⅰ-Ⅱ. These 60 patients were randomly divided into forgetful analgesia induction-tracheal intubation group (group A, n=30 and rapid induction-tracheal intubation group (group B, n=30. The heart rate (HR, mean arterial pressure (MAP, pulse oxygen saturation (SpO2 at the time point of before induction (T0, before intubation (T1, at the moment of intubation (T2 and 3 min after intubation (T3 were determined in both groups. Administration times of ephedrine hydrochloride and atropine was recorded in both groups. Results There was no significant difference in HR, MAP, SpO2 before and after induction in group A. In the patients of group B, the HR increased and MAP decreased after induction compared with those before induction (P<0.05, and the change of SpO2 was not significant. Ephedrine hydrochloride and atropine were administrated in both groups, and the cases and times of ephedrine hydrochloride administration were more in group B than in group A (P<0.05. Conclusion The forgetful analgesia induction-tracheal intubation could effectively control the stress response and reduce the fluctuation in hemodynamics during induction of anesthesia in patients with obstructive jaundice. DOI: 10.11855/j.issn.0577-7402.2014.02.15

  5. [Mood induction procedures: a critical review].

    Science.gov (United States)

    Gilet, A-L

    2008-06-01

    For a long period in the history of psychological research, emotion and cognition have been studied independently, as if one were irrelevant to the other. The renewed interest of researchers for the study of the relations between cognition and emotion has led to the development of a range of laboratory methods for inducing temporary mood states. This paper aims to review the main mood induction procedures allowing the induction of a negative mood as well as a positive mood, developed since the pioneer study of Schachter and Singer [Psychol Rev 69 (1962) 379-399] and to account for the usefulness and problems related to the use of such techniques. The first part of this paper deals with the detailed presentation of some of the most popular mood induction procedures according to their type: simple (use of only one mood induction technique) or combined (association of two or more techniques at once). The earliest of the modern techniques is the Velten Mood Induction Procedure [Behav Res Ther 6 (1968) 473-482], which involves reading aloud sixty self-referent statements progressing from relative neutral mood to negative mood or dysphoria. Some researchers have varied the procedure slightly by changing the number of the statements [Behav Res Ther 21 (1983) 233-239, Br J Clin Psychol 21 (1982) 111-117, J Pers Soc Psychol 35 (1977) 625-636]. Various other mood induction procedures have been developed including music induction [Cogn Emotion 11 (1997) 403-432, Br J Med Psychol 55 (1982) 127-138], film clip induction [J Pers Soc Psychol 20 (1971) 37-43, Cogn Emotion 7 (1993) 171-193, Rottenberg J, Ray RR, Gross JJ. Emotion elicitation using films. In: Coan JA, Allen JJB, editors. The handbook of emotion elicitation and assessment. New York: Oxford University Press, 2007], autobiographical recall [J Clin Psychol 36 (1980) 215-226, Jallais C. Effets des humeurs positives et négatives sur les structures de connaissances de type script. Thèse de doctorat non publi

  6. Quality Induction: The Effects of Comprehensive Induction on New Teacher Retention and Job Satisfaction

    Science.gov (United States)

    Hendricks-Harris, Mary Therese

    2012-01-01

    This investigation examined the effect of a comprehensive new teacher induction program on teacher retention and job satisfaction in one suburban school district. New teachers are retained at low rates, and districts are spending resources in an attempt to decrease this number. New teacher induction includes supports for new teachers in their…

  7. Similarity, Induction, Naming, and Categorization (SINC): Generalization or Inductive Reasoning? Reply to Heit and Hayes (2005)

    Science.gov (United States)

    Sloutsky, Vladimir M.; Fisher, Anna V.

    2006-01-01

    This article is a response to E. Heit and B. K. Hayes's comment on the target article "Induction and Categorization in Young Children: A Similarity-Based Model" (V. M. Sloutsky & A. V. Fisher, 2004a). The response discusses points of agreement and disagreement with Heit and Hayes; phenomena predicted by similarity, induction, naming, and…

  8. Induction sensor for measuring the accelerating voltage in an iron-free induction accelerator

    International Nuclear Information System (INIS)

    Bol'nykh, N.S.; Il'in, Yu.M.; Kostyushok, A.A.; Suvorov, V.A.

    1987-01-01

    An inductive sensor is described for measuring the amplitude and form of the accelerating-voltage pulse in the storage coils in a radial iron-free linear induction accelerator. The sensor does not respond to interference from external fields and does not require adjustment after calibration

  9. What Can a Hypnotic Induction Do?

    Science.gov (United States)

    Woody, Erik; Sadler, Pamela

    2016-10-01

    In contrast to how recent definitions of hypnosis describe the induction, a work-sample perspective is advocated that characterizes the induction as an initial, stage-setting phase encompassing everything in a hypnotic session up to the first hypnotic suggestion of particular relevance to the therapeutic or research goals at hand. Four major ways are then discussed in which the induction could affect subsequent hypnotic responses: It may provide information about how subsequent behaviors are to be enacted; it may provide cues about the nature of the interpersonal interaction to be expected in hypnosis; it may provide meta-suggestions, defined as suggestive statements intended to enhance responses to subsequent hypnotic suggestions; and it may provide a clear transition to help allow new behaviors and experiences to emerge. Several ideas for future research are advanced, such as mapping hypnosis style onto the interpersonal circumplex, evaluating whether attentional-state changes measured at the end of the induction actually mediate subsequent hypnotic responsiveness, and systematically examining the impact of ritual-like aspects of inductions.

  10. Induction of labour in postdates pregnant women

    International Nuclear Information System (INIS)

    Haq, A.N.; Ahsan, S.; Sher, Z.

    2012-01-01

    Objective: To differentiate the effect of gestation on the mode of delivery by analysing the difference in the mode of induction, length of labour and the difference in parity or Bishop score and their effect on the mode of delivery of postdates women. Study Design: A cross-sectional observational study. Place and Duration of Study: PAEC General Hospital, Islamabad, from July 2006 to July 2008. Methodology:Patients were induced at 41 weeks (Group B) and > 40 weeks (Group A) of gestation. Tab misoprostol and PGE2 tablets were administered according to amniotic fluid index (AFI) and parity . Study variables included duration of gestation, mode of induction, length of labour, difference in parity and Bishop score assessed before induction in each group. The outcome was assessed by applying Chi-square test by comparing mode of delivery with the study variables in both groups. Results: A total of 78 patients were inducted in the study. They were divided in group B (n = 39) induced 41 weeks and group A (n = 39) induced at 40 weeks. Eighty four percent (n = 35) patients in group B delivered vaginally as compared to 71% (n = 28) in the 40 weeks group (p < 0.0001). The higher number of vaginal deliveries in 41 weeks group was independent of association between the induction agent, parity and mode of delivery. Conclusion: The mean length of gestation was the single most important factor among the studied variables in predicting a vaginal delivery. (author)

  11. Two-Phase Induction Motor Drives

    Directory of Open Access Journals (Sweden)

    Gholam Reza Arab Markadeh

    2010-10-01

    Full Text Available The lack of variable-speed drives for two (single induction motor is a reality. This article attempts mainly to investigate the reasons for this lack of variable – speed drives. This paper deals with literature survey of various existing converter topologies, which have been proposed for adjustable speed single phase induction motor drives. Various converter topologies have been compared in this paper. Among these converter topologies, the adjustable frequency PWM inverter is the best choice for single-phase induction motor drives. However, adjustable-frequency drives have not been widely used with single-phase Induction motors. The open-loop constant V/F control law cannot be used with the single-phase induction motor drives as it is used with three phase motors. The variation of the operating frequency at lower speed range with constant load torque causes variation in motor's slip. A constant V/F control is suitable only over the upper speed range.

  12. UHPLC: The Greening Face of Liquid Chromatography.

    Science.gov (United States)

    Cielecka-Piontek, Judyta; Zalewski, Przemysław; Jelińska, Anna; Garbacki, Piotr

    2013-01-01

    Pharmaceutical analysis based on chromatographic separation is an important part of studies aimed at developing routine quality analysis of drugs. High-performance liquid chromatography (HPLC) is one of the main analytical techniques recommended for drug analysis. Although it meets many criteria vital for analysis, it is time-consuming and uses a relatively high amount of organic solvents compared to other analytical techniques. Recently, Ultra-high-performance liquid chromatography (UHPLC) has been frequently proposed as an alternative to HPLC, which means introducing an environment-friendly approach to drug analysis achieved by reducing the consumption of solvents. It also offers greater chromatographic resolution and higher sensitivity as well as requiring less time due to faster analysis. This review focuses on the basics of UHPLC, compares that technique with HPLC and discusses the possibilities of applying UHPLC for the analysis of different pharmaceuticals and biopharmaceuticals.

  13. Gas chromatography of β-diketonates

    International Nuclear Information System (INIS)

    Burgett, C.A.

    1976-01-01

    The history of separation of metal complexes by gas chromatography is reviewed. The greatest success has been achieved with metal halides or metal β-diketonates, particularly with chelates of the small elements, Be and Al, and the extremely inert chromium diketonates. Many problems still remain concerning the development of suitable chromatographic techniques for many chelates; however, the technique of synergic solvent extraction, mixed-ligand complex chromatography, the synthesis of new heteroatomic ligands, and the advent of new liquid phases are discussed as means to increase the number of unique techniques for separation and analysis of metals. Methods are suggested and references are cited for chromatographic analysis of elements in the following groups: alkali metals, alkaline earths, Group IIIA, IVB, VB, VIB, VIIB, VIII, IB, and IIB. Special attention is given to separation of the volatile complexes of Sc, Y, the lanthanides, the actinides, and Pb. 156 references

  14. Boron isotopic enrichment by displacement chromatography

    International Nuclear Information System (INIS)

    Mohapatra, K.K.; Bose, Arun

    2014-01-01

    10 B enriched boron is used in applications requiring high volumetric neutron absorption (absorption cross section- 3837 barn for thermal and 1 barn for 1 MeV fast neutron). It is used in fast breeder reactor (as control rod material), in neutron counter, in Boron Neutron Capture Therapy etc. Owing to very small separation factor, boron isotopic enrichment is a complex process requiring large number of separation stages. Heavy Water Board has ventured in industrial scale production of 10 B enriched boron using Exchange Distillation Process as well as Ion Displacement Chromatography Process. Ion Displacement Chromatography process is used in Boron Enrichment Plant at HWP, Manuguru. It is based on isotopic exchange between borate ions (B(OH) 4 - ) on anion exchange resin and boric acid passing through resin. The isotopic exchange takes place due to difference in zero point energy of 10 B and 11 B

  15. Instrumentation for analytical scale supercritical fluid chromatography.

    Science.gov (United States)

    Berger, Terry A

    2015-11-20

    Analytical scale supercritical fluid chromatography (SFC) is largely a sub-discipline of high performance liquid chromatography (HPLC), in that most of the hardware and software can be used for either technique. The aspects that separate the 2 techniques stem from the use of carbon dioxide (CO2) as the main component of the mobile phase in SFC. The high compressibility and low viscosity of CO2 mean that pumps, and autosamplers designed for HPLC either need to be modified or an alternate means of dealing with compressibility needs to be found. The inclusion of a back pressure regulator and a high pressure flow cell for any UV-Vis detector are also necessary. Details of the various approaches, problems and solutions are described. Characteristics, such as adiabatic vs. isothermal compressibility, thermal gradients, and refractive index issues are dealt with in detail. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Spillage detector for liquid chromatography systems

    Science.gov (United States)

    Jarvis, M. J.; Fulton, D. S. (Inventor)

    1986-01-01

    A spillage detector device for use in conjunction with fractionation of liquid chromatography systems which includes a spillage recieving enclosure beneath the fractionation area is described. A sensing device having a plurality of electrodes of alternating polarity is mounted within the spillage recieving enclosure. Detection circuitry, responsive to conductivity between electrodes, is operatively connected to the sensing device. The detection circuitry feeds into the output circuitry. The output circuit has relaying and switching circuitry directed to a solenoid, an alarm system and a pump. The solenoid is connected to the pliable conduit of the chromatography system. The alarm system comprises an audio alarm and a visual signal. A 115-volt power system interconnected with the pump, the solenoid, the sensing device, and the detection and output circuitry.

  17. Integrated sampling vs ion chromatography: Mathematical considerations

    International Nuclear Information System (INIS)

    Sundberg, L.L.

    1992-01-01

    This paper presents some general purpose considerations that can be utilized when comparisons are made between the results of integrated sampling over several hours or days, and ion chromatography where sample collection times are measured in minutes. The discussion is geared toward the measurement of soluble transition metal ions in BWR feedwater. Under steady-state conditions, the concentrations reported by both techniques should be in reasonable agreement. Transient operations effect both types of measurements. A simplistic model, applicable to both sampling techniques, is presented that demonstrates the effect of transients which occur during the acquisition of a steady-state sample. For a common set of conditions, the integrated concentration is proportional to the concentration and duration of the transient, and inversely proportional to the sample collection time. The adjustment of the collection period during a known transient allows an estimation of peak transient concentration. Though the probability of sampling a random transient with the integrated sampling technique is very high, the magnitude is severely diluted with long integration times. Transient concentrations are magnified with ion chromatography, but the probability of sampling a transient is significantly lower using normal ion chromatography operations. Various data averaging techniques are discussed for integrated sampling and IC determinations. The use of time-weighted averages appears to offer more advantages over arithmetic and geometric means for integrated sampling when the collection period is variable. For replicate steady-state ion chromatography determinations which bracket a transient sample, it may be advantageous to ignore the calculation of averages, and report the data as trending information only

  18. Use of macroporous plastics in extraction chromatography

    International Nuclear Information System (INIS)

    Braun, T.; Farac, A.B.

    1978-01-01

    Possibilities are analysed which the use of porous plastics (polyvinyl chloride, siloxane rubber, polyurethane, polystyrene and etc.) as carriers presents in extraction chromatography. Short characteristics of chemical and physical properties of macroporous carriers is given. The importance of correct chromatographic column packing is noted to obtain columns with good hydrodynamic characteristics and operational properties. Examples of using columns with macroporous carriers in radiochemistry and inorganic chemistry for element separation are given

  19. Ion exchange and liquid column chromatography

    International Nuclear Information System (INIS)

    Walton, H.F.

    1980-01-01

    Major accomplishments in liquid chromatography for the past two years and reported in journals available to December 31, 1979 are reviewed. Emphasis has been placed on principles and methodology with some representative examples of application included. Applications are illustrated in two rather lenghtly tables, one covering inorganic ions and the other covering organic compounds. 544 references, 8 books, and 15 reviews are listed in the bibliography

  20. Design of preparative-supercritical fluid chromatography.

    Science.gov (United States)

    Rajendran, Arvind

    2012-08-10

    Preparative supercritical fluid chromatography (prep-SFC) is an important separation process in the chromatographers toolbox. Owing to the unique properties of the mobile phase, which is predominantly CO(2), the behavior of SFC is markedly different from high performance liquid chromatography (HPLC). This review article focuses on the scale-up of preparative chromatography. The basics of SFC, with particular focus on highlighting the key differences between SFC and HPLC, are introduced. Then, a framework for rational design of prep-SFC is proposed. This framework is based on obtaining basic system parameters from analytical scale equipment, i.e., with very small amount of material, and performing design and optimization in silico to evaluate process performance and to identify operating conditions for scale-up. The tools required to obtain the input parameters such as adsorption isotherms are discussed and the development of the design and optimization framework is elaborated. Examples from the literature which use this approach for successful scale-up are provided. Finally the design of multi-column SFC systems is discussed. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Compound immobilization and drug-affinity chromatography.

    Science.gov (United States)

    Rix, Uwe; Gridling, Manuela; Superti-Furga, Giulio

    2012-01-01

    Bioactive small molecules act through modulating a yet unpredictable number of targets. It is therefore of critical importance to define the cellular target proteins of a compound as an entry point to understanding its mechanism of action. Often, this can be achieved in a direct fashion by chemical proteomics. As with any affinity chromatography, immobilization of the bait to a solid support is one of the earliest and most crucial steps in the process. Interfering with structural features that are important for identification of a target protein will be detrimental to binding affinity. Also, many molecules are sensitive to heat or to certain chemicals, such as acid or base, and might be destroyed during the process of immobilization, which therefore needs to be not only efficient, but also mild. The subsequent affinity chromatography step needs to preserve molecular and conformational integrity of both bait compound and proteins in order to result in the desired specific enrichment while ensuring a high level of compatibility with downstream analysis by mass spectrometry. Thus, the right choice of detergent, buffer, and protease inhibitors is also essential. This chapter describes a widely applicable procedure for the immobilization of small molecule drugs and for drug-affinity chromatography with subsequent protein identification by mass spectrometry.

  2. A high-current racetrack induction accelerator

    International Nuclear Information System (INIS)

    Mondelli, A.; Roberson, C.W.

    1983-01-01

    In this paper, the energy and system scaling laws of the Racetrack Induction Accelerator are determined and its operating principles are discussed. This device is a cyclic accelerator that is capable of multi-kiloamp operation. Long pulse induction linac technology is used to obtain short acceleration times. The accelerator consists of a long-pulse linear induction module and a racetrack beam transport system. For detailed studies of the particle dynamics in a racetrack, a numerical model is required to integrate the fully-relativistic single-particle equations of motion in an externally applied magnetic field. The numerical model is a compromise between the need for a large rotational transform and the need for a reasonable volume within the separatrix

  3. Scalable conditional induction variables (CIV) analysis

    DEFF Research Database (Denmark)

    Oancea, Cosmin Eugen; Rauchwerger, Lawrence

    2015-01-01

    parallelizing compiler and evaluated its impact on five Fortran benchmarks. We have found that that there are many important loops using CIV subscripts and that our analysis can lead to their scalable parallelization. This in turn has led to the parallelization of the benchmark programs they appear in.......Subscripts using induction variables that cannot be expressed as a formula in terms of the enclosing-loop indices appear in the low-level implementation of common programming abstractions such as filter, or stack operations and pose significant challenges to automatic parallelization. Because...... the complexity of such induction variables is often due to their conditional evaluation across the iteration space of loops we name them Conditional Induction Variables (CIV). This paper presents a flow-sensitive technique that summarizes both such CIV-based and affine subscripts to program level, using the same...

  4. 1 MV low-induction pulse generator

    International Nuclear Information System (INIS)

    Koba, G.I.; Koba, Yu.V.; Slivkov, I.N.; Sukhov, A.D.; Tarumov, Eh.Z.

    1980-01-01

    A high-voltage pulse generator is described. The generator Uses the Arkadiev-Marx circuit at 1 MV voltage and 12 kJ energy; the inductance of the discharge circuit is 1.3 μN. Low inductance of the generator has been obtained due to the use of low-inductance capacitors and employment of bifilar buses with oil barrier insulation. To provide reliable generator triggering, an ignition circuit has been developed with a resistive coupling between generator steps, based on controlled three-electrode sparkgaps with a distorted field. The generator switching time is slightly dependent on pressure and constitutes 200-300 ns. The generator efficiency is 83%

  5. Induction heat treatment of laser welds

    DEFF Research Database (Denmark)

    Bagger, Claus; Olsen, Flemming Ove; Sørensen, Joakim Ilsing

    2003-01-01

    of an induction coil. A number of systematic laboratory tests were then performed in order to study the effects of the coil on bead-on-plate laser welded samples. In these tests, important parameters such as coil current and distance between coil and sample were varied. Temperature measurements were made...... the laser beam as close as possible. After welding, the samples were quality assessed according to ISO 13.919-1 and tested for hardness. The metallurgical phases are analysed and briefly described. A comparison between purely laser welded samples and induction heat-treated laser welded samples is made......In this paper, a new approach based on induction heat-treatment of flat laser welded sheets is presented. With this new concept, the ductility of high strength steels GA260 with a thickness of 1.8 mm and CMn with a thickness of 2.13 mm is believed to be improved by prolonging the cooling time from...

  6. Stator Fault Modelling of Induction Motors

    DEFF Research Database (Denmark)

    Thomsen, Jesper Sandberg; Kallesøe, Carsten

    2006-01-01

    In this paper a model of an induction motor affected by stator faults is presented. Two different types of faults are considered, these are; disconnection of a supply phase, and inter-turn and turn-turn short circuits inside the stator. The output of the derived model is compared to real measurem......In this paper a model of an induction motor affected by stator faults is presented. Two different types of faults are considered, these are; disconnection of a supply phase, and inter-turn and turn-turn short circuits inside the stator. The output of the derived model is compared to real...... measurements from a specially designed induction motor. With this motor it is possible to simulate both terminal disconnections, inter-turn and turn-turn short circuits. The results show good agreement between the measurements and the simulated signals obtained from the model. In the tests focus...

  7. High power switches for ion induction linacs

    International Nuclear Information System (INIS)

    Humphries, S.; Savage, M.; Saylor, W.B.

    1985-01-01

    The success of linear induction ion accelerators for accelerator inertial fusion (AIF) applications depends largely on innovations in pulsed power technology. There are tight constraints on the accuracy of accelerating voltage waveforms to maintain a low momentum spread. Furthermore, the non-relativistic ion beams may be subject to a klystronlike interaction with the accelerating cavities, leading to enhanced momentum spread. In this paper, we describe a novel high power switch with a demonstrated ability to interrupt 300 A at 20 kV in less than 60 ns. The switch may allow the replacement of pulse modulators in linear induction accelerators with hard tube pulsers. A power system based on a hard tube pulser could solve the longitudinal instability problem while maintaining high energy transfer efficiency. The problem of longitudinal beam control in ion induction linacs is reviewed in Section 2. Section 3 describes the principles of the plasma flow switch. Experimental results are summarized in Section 4

  8. High power switches for ion induction linacs

    International Nuclear Information System (INIS)

    Humphries, S. Jr.; Savage, M.; Saylor, W.B.

    1985-01-01

    The success of linear induction ion accelerators for accelerator inertial fusion (AIF) applications depends largely on innovations in pulsed power technology. There are tight constraints on the accuracy of accelerating voltage waveforms to maintain a low momentum spread. Furthermore, the non-relativistic ion beams may be subject to a klystron-like interaction with the accelerating cavities leading to enhanced momentum spread. In this paper, the author describe a novel high power switch with a demonstrated ability to interrupt 300 A at 20 kV in less than 60 ns. The switch may allow the replacement of pulse modulators in linear induction accelerators with hard tube pulsers. A power system based on a hard tube pulser could solve the longitudinal instability problem while maintaining high energy transfer efficiency. The problem of longitudinal beam control in ion induction linacs is reviewed in Section 2. Section 3 describes the principles of the plasma flow switch. Experimental results are summarized in Section 4

  9. Energy Optimal Control of Induction Motor Drives

    DEFF Research Database (Denmark)

    Abrahamsen, Flemming

    This thesis deals with energy optimal control of small and medium-size variable speed induction motor drives for especially Heating, Ventilation and Air-Condition (HVAC) applications. Optimized efficiency is achieved by adapting the magnetization level in the motor to the load, and the basic...... demonstrated that energy optimal control will sometimes improve and sometimes deteriorate the stability. Comparison of small and medium-size induction motor drives with permanent magnet motor drives indicated why, and in which applications, PM motors are especially good. Calculations of economical aspects...... improvement by energy optimal control for any standard induction motor drive between 2.2 kW and 90 kW. A simple method to evaluate the robustness against load disturbances was developed and used to compare the robustness of different motor types and sizes. Calculation of the oscillatory behavior of a motor...

  10. Induction linacs for heavy ion fusion research

    International Nuclear Information System (INIS)

    Fessenden, T.J.; Avery, R.T.; Brady, V.; Bisognano, J.; Celata, C.; Chupp, W.W.; Faltens, A.; Hartwig, E.C.; Judd, D.L.; Keefe, D.; Kim, C.H.; Laslett, L.J.; Lee, E.P.; Rosenblum, S.S.; Smith, L.; Warwick, A.

    1984-01-01

    The new features of employing an induction linac as a driver for inertial fusion involve (1) transport of high-current low-emittance heavy ion beams. (2) multiple independently-focussed beams threading the same accelerator structure, and (3) synthesis of voltage waveforms to accomplish beam current amplification. A research program is underway at LBL to develop accelerators that test all these features with the final goal of producing an ion beam capable of heating matter to proportional70 eV. This paper presents a discussion of some properties of induction linacs and how they may be used for HIF research. Physics designs of the High Temperature Experiment (HTE) and the Multiple Beam Experiment (MBE) accelerators are presented along with initial concepts of the MBE induction units. (orig.)

  11. Heavy ion induction linacs for fusion

    International Nuclear Information System (INIS)

    Bangerter, R.O.; Ho, D.D.M.

    1991-01-01

    In 1976 Denis Keefe proposed the heavy ion induction linac as a driver for inertial confinement fusion (ICF) power plants. Subsequent research has established that heavy ion fusion (HIF) is potentially an attractive energy source and has identified the issues that must be resolved to make HIF a reality. The principal accelerator issues are achieving adequately low transverse and longitudinal emittance and acceptable cost. Results from the single and multiple beam experiments at LBL on transverse emittance are encouraging. A predicted high current longitudinal instability that can affect longitudinal emittance is currently being studied. This paper presents an overview of economics and ICF target requirements and their relationship to accelerator design. It also presents a summary of the status of heavy ion induction linac research. It concludes with a discussion of research plans, including plans for the proposed Induction Linac Systems Experiments (ILSE)

  12. Relations between inductive reasoning and deductive reasoning.

    Science.gov (United States)

    Heit, Evan; Rotello, Caren M

    2010-05-01

    One of the most important open questions in reasoning research is how inductive reasoning and deductive reasoning are related. In an effort to address this question, we applied methods and concepts from memory research. We used 2 experiments to examine the effects of logical validity and premise-conclusion similarity on evaluation of arguments. Experiment 1 showed 2 dissociations: For a common set of arguments, deduction judgments were more affected by validity, and induction judgments were more affected by similarity. Moreover, Experiment 2 showed that fast deduction judgments were like induction judgments-in terms of being more influenced by similarity and less influenced by validity, compared with slow deduction judgments. These novel results pose challenges for a 1-process account of reasoning and are interpreted in terms of a 2-process account of reasoning, which was implemented as a multidimensional signal detection model and applied to receiver operating characteristic data. PsycINFO Database Record (c) 2010 APA, all rights reserved.

  13. Armature design for coaxial induction launchers

    International Nuclear Information System (INIS)

    Andrews, J.A.; Devine, J.R.

    1991-01-01

    This paper reports on the armature design for a coaxial induction launcher that is influenced by a large set of highly coupled parameters. The simplifying assumptions often employed in coaxial accelerator analysis, such as a uniform or sinusoidal axial distribution of the azimuthal armature current, are unrealistic in induction launchers with monolithic single-turn armatures. In order to better understand the true dynamic behavior of coaxial accelerators, the Center for Electromechanics at The University of Texas at Austin (CEM-UT) has developed series of computer codes based on the current filament method. By utilizing these performance codes in conjunction with electromagnetic (EM) and mechanical finite element programs, it is now possible to design high performance induction launchers with armatures that can withstand the considerable mechanical and thermal loads inherent in a coaxial accelerator launch

  14. Structured statistical models of inductive reasoning.

    Science.gov (United States)

    Kemp, Charles; Tenenbaum, Joshua B

    2009-01-01

    Everyday inductive inferences are often guided by rich background knowledge. Formal models of induction should aim to incorporate this knowledge and should explain how different kinds of knowledge lead to the distinctive patterns of reasoning found in different inductive contexts. This article presents a Bayesian framework that attempts to meet both goals and describes [corrected] 4 applications of the framework: a taxonomic model, a spatial model, a threshold model, and a causal model. Each model makes probabilistic inferences about the extensions of novel properties, but the priors for the 4 models are defined over different kinds of structures that capture different relationships between the categories in a domain. The framework therefore shows how statistical inference can operate over structured background knowledge, and the authors argue that this interaction between structure and statistics is critical for explaining the power and flexibility of human reasoning.

  15. Induction linacs for heavy ion fusion research

    Energy Technology Data Exchange (ETDEWEB)

    Fessenden, T.J.

    1984-05-01

    The new features of employing an induction linac as a driver for inertial fusion involve (1) transport of high-current low-emittance heavy ion beams, (2) multiple independently-focussed beams threading the same accelerator structure, and (3) synthesis of voltage waveforms to accomplish beam current amplification. A research program is underway at LBL to develop accelerators that test all these features with the final goal of producing an ion beam capable of heating matter to approx. 70 eV. This paper presents a discussion of some properties of induction linacs and how they may be used for HIF research. Physics designs of the High Temperature Experiment (HTE) and the Multiple Beam Experiment (MBE) accelerators are presented along with initial concepts of the MBE induction units.

  16. Application and Perspectives of Multiphase Induction Motors

    Directory of Open Access Journals (Sweden)

    Benas Kundrotas

    2012-04-01

    Full Text Available The article considers the areas of applying multiphase induction motors. Their advantages against three phase motors have become the main reason for employing them in multiphase drives. The paper deals with the six-phase induction motor having two similar three phase windings in the stator shifted by 30 degrees in space and three phase windings in the rotor. Differential equations for this motor are presented and transformed to dq synchronous reference frame. The transformed equations are expressed in a matrix form and solved by MATLAB software using the Dormand-Prince (ode45 method. The transient characteristics of the torque, speed and current of the six-phase induction motor are calculated and discussed.Article in Lithuanian

  17. A logic for inductive probabilistic reasoning

    DEFF Research Database (Denmark)

    Jaeger, Manfred

    2005-01-01

    Inductive probabilistic reasoning is understood as the application of inference patterns that use statistical background information to assign (subjective) probabilities to single events. The simplest such inference pattern is direct inference: from '70% of As are Bs" and "a is an A" infer...... that a is a B with probability 0.7. Direct inference is generalized by Jeffrey's rule and the principle of cross-entropy minimization. To adequately formalize inductive probabilistic reasoning is an interesting topic for artificial intelligence, as an autonomous system acting in a complex environment may have...... to base its actions on a probabilistic model of its environment, and the probabilities needed to form this model can often be obtained by combining statistical background information with particular observations made, i.e., by inductive probabilistic reasoning. In this paper a formal framework...

  18. Rethinking Reinforcement: Allocation, Induction, and Contingency

    Science.gov (United States)

    Baum, William M

    2012-01-01

    The concept of reinforcement is at least incomplete and almost certainly incorrect. An alternative way of organizing our understanding of behavior may be built around three concepts: allocation, induction, and correlation. Allocation is the measure of behavior and captures the centrality of choice: All behavior entails choice and consists of choice. Allocation changes as a result of induction and correlation. The term induction covers phenomena such as adjunctive, interim, and terminal behavior—behavior induced in a situation by occurrence of food or another Phylogenetically Important Event (PIE) in that situation. Induction resembles stimulus control in that no one-to-one relation exists between induced behavior and the inducing event. If one allowed that some stimulus control were the result of phylogeny, then induction and stimulus control would be identical, and a PIE would resemble a discriminative stimulus. Much evidence supports the idea that a PIE induces all PIE-related activities. Research also supports the idea that stimuli correlated with PIEs become PIE-related conditional inducers. Contingencies create correlations between “operant” activity (e.g., lever pressing) and PIEs (e.g., food). Once an activity has become PIE-related, the PIE induces it along with other PIE-related activities. Contingencies also constrain possible performances. These constraints specify feedback functions, which explain phenomena such as the higher response rates on ratio schedules in comparison with interval schedules. Allocations that include a lot of operant activity are “selected” only in the sense that they generate more frequent occurrence of the PIE within the constraints of the situation; contingency and induction do the “selecting.” PMID:22287807

  19. Modelling imperfect adherence to HIV induction therapy

    Directory of Open Access Journals (Sweden)

    Smith? Robert J

    2010-01-01

    Full Text Available Abstract Background Induction-maintenance therapy is a treatment regime where patients are prescribed an intense course of treatment for a short period of time (the induction phase, followed by a simplified long-term regimen (maintenance. Since induction therapy has a significantly higher chance of pill fatigue than maintenance therapy, patients might take drug holidays during this period. Without guidance, patients who choose to stop therapy will each be making individual decisions, with no scientific basis. Methods We use mathematical modelling to investigate the effect of imperfect adherence during the inductive phase. We address the following research questions: 1. Can we theoretically determine the maximal length of a possible drug holiday and the minimal number of doses that must subsequently be taken while still avoiding resistance? 2. How many drug holidays can be taken during the induction phase? Results For a 180 day therapeutic program, a patient can take several drug holidays, but then has to follow each drug holiday with a strict, but fairly straightforward, drug-taking regimen. Since the results are dependent upon the drug regimen, we calculated the length and number of drug holidays for all fifteen protease-sparing triple-drug cocktails that have been approved by the US Food and Drug Administration. Conclusions Induction therapy with partial adherence is tolerable, but the outcome depends on the drug cocktail. Our theoretical predictions are in line with recent results from pilot studies of short-cycle treatment interruption strategies and may be useful in guiding the design of future clinical trials.

  20. A theory evaluation of an induction programme

    Directory of Open Access Journals (Sweden)

    Kenrick Hendricks

    2012-07-01

    Full Text Available Orientation: An induction programme is commonly used to help new employees understand their job within the organisation. Research purpose: The main aim of this study was to examine whether or not the programme theory of an induction programme was plausible and would lead to the intended outcomes as described by the programme manager. Motivation for the study: Induction training is one of the most common training programmes in an organisation. However, there is little research to evaluate whether or not the activities of an induction programme will lead to the intended outcomes of such a programme. Research design, approach and method: This theory evaluation used a descriptive design. One hundred and thirteen employees of a media company completed a ten-item, five-point Likert scale which measured their perceptions of the programme’s outcome, identification with the organisation and intentions to stay with the organisation. Main findings: From this theory evaluation it was apparent that an induction programme based on an implausible programme theory could be problematic. An implausible programme theory affects the design of the programme activities and unsuitable activities may not deliver the desired outcomes. Practical/managerial implications: The intention of the evaluation is to guide human resource managers through a process of replacing an implausible programme theory with one that is plausible, and which ensures better alignment of programme activities and outcomes. Contribution/value-add: The evaluators showed how a plausible programme theory could improve programme design. This redesigned induction programme may lead to benefits, such as staff retention and company identification, rather than the vague assumption that it has been conforming to a legal obligation.

  1. About Eddy Currents in Induction Melting Processes

    Directory of Open Access Journals (Sweden)

    Gafiţa Nicolae-Bogdan

    2008-05-01

    Full Text Available In this paper we present a method forcomputing the eddy currents in induction meltingprocesses for non-ferrous alloys. We take intoconsideration the situation when only the crucible ismoving, inside the coils. This fact makes differentialcomputation methods to be hard to apply, because isnecessary to generate a new mesh and a new systemmatrix for every for every new position of the cruciblerelated to the coils. Integral methods cancel thisdrawback because the mesh is generated only for thedomains with eddy currents. For integral methods, themesh and the inductance matrix remain unchangedduring the movement of the crucible; only the free termsof the equation system will change.

  2. Self-inductance of chiral conducting nanotubes

    International Nuclear Information System (INIS)

    Miyamoto, Yoshiyuki; Rubio, Angel; Louie, Steven G.; Cohen, Marvin L.

    1998-01-01

    Chiral conductivity in nanotubes has recently been predicted theoretically. The realization and application of chiral conducting nanotubes can be of great interest from both fundamental and technological viewpoints. These chiral currents, if they are realized, can be detected by measuring the self-inductance. We have treated Maxwell's equations for chiral conducting nanotubes (nanocoils) and find that the self-inductance and the resistivity of nanocoils should depend on the frequency of the alternating current even when the capacitance of the nanocoils is not taken into account. This is in contrast to elementary treatment of ordinary coils. This fact is useful to distinguish nanocoils by electrical measurements

  3. Microcolumn high pressure liquid chromatography with a glass-frit nebulizer interface for plasma emission detection

    International Nuclear Information System (INIS)

    Ibrahim, M.; Nisamaneepong, W.; Caruso, J.

    1985-01-01

    Microcolumn high pressure liquid chromatography (micro-HPLC) is rapidly gaining recognition as a practical separation tool for organometallic compounds. The use of the inductively coupled plasma (ICP) as a detector for micro-HPLC is studied. Several miniaturized glass-frit nebulizers are investigated as interfaces between the output of the microbore column and the ICP torch. Their performance with aqueous and methanolic solutions is evaluated by direct nebulization and flow injection analysis. The most efficient of these nebulizers is used in the micro-HPLC/ICP study of some Cd, Pb, and Zn organometallic compounds. Detection limits of 1.92 ng of Pb for tetramethyllead and 5.01 ng of Pb for tetraethyllead are obtained and compared with regular HPLC/ICP of these same compounds. Approximately equivalent detection limits were obtained when using a microwave induced plasma as an alternate plasma source

  4. Inductive Loops for Sensing Position as Signature Signals

    International Nuclear Information System (INIS)

    Larbani, Sofiane; Malik, Noreha Abdul; Nordin, Anis Norashikin; Khan, Sheroz; Shobaki, Mohammad

    2013-01-01

    In this paper, an inductive sensing technique made of a special shaped inductive loop is proposed. The inductive loop has an inner turn fitted within an outer turn, making a total inductance value 100μH. This loop is made to be shown with balanced response using three capacitance values of 0.068μF each when a sinusoidal voltage source of 5V peak-to-peak is applied. The variation of the relative permeability of the inductance of the inductive loop (AL) results in a variation of the overall inductance value (L+AL), that causes the output signal to change in term of shape and amplitude for variation of total inductance sweep over a given period of time. As a result of change in inductance value (lμH) there is a correspondence increase of 300mV. Theoretical derivations have showed in close agreement with the simulation plots obtained using Multisim software

  5. Inductive Loops for Sensing Position as Signature Signals

    Science.gov (United States)

    Larbani, Sofiane; Malik, Noreha Abdul; Norashikin Nordin, Anis; Khan, Sheroz; Shobaki, Mohammad

    2013-12-01

    In this paper, an inductive sensing technique made of a special shaped inductive loop is proposed. The inductive loop has an inner turn fitted within an outer turn, making a total inductance value 100μH. This loop is made to be shown with balanced response using three capacitance values of 0.068μF each when a sinusoidal voltage source of 5V peak-to-peak is applied. The variation of the relative permeability of the inductance of the inductive loop (AL) results in a variation of the overall inductance value (L+AL), that causes the output signal to change in term of shape and amplitude for variation of total inductance sweep over a given period of time. As a result of change in inductance value (lμH) there is a correspondence increase of 300mV. Theoretical derivations have showed in close agreement with the simulation plots obtained using Multisim software.

  6. Analysis of pollutants in air and water using gas chromatography and headspace gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Stenner, H.

    1980-01-01

    The combination 'personal sampling' with headspace gas chromatography to determine traces of formaldehyde, phenol and benzene in air is investigated in this work, with the aim of developing maximum workplace concentration values (MWL values). Further possible applications of gas chromatography in trace analysis in the environmentally protected area. The analysis of chromium in waste waters (Cr III as acetyl acetonate complex) is investigated as further possible application, whereby optimum conditions are obtained. A modified flame ionization detector was used to increase the detection sensitivity.

  7. Thin-layer chromatography - liquid chromatography, an ideal supplement demonstrated by the separation of lanthanoids

    International Nuclear Information System (INIS)

    Specker, H.; Hufnagel, A.

    1984-01-01

    All lanthanoids have been separated by thin-layer chromatography (TLC) with short retention times by using a mixture of ether/tetrahydrofurane (THF)/bis-(2-ethylhexyl)-phosphate (HDEHP)/nitric acid. The eluent was empirically tested by synergistic effects. The results have been transferred to high-performance liquid chromatography /HPLC). It was possible to use the same eluent in TLC and HPLC both for the analytical separation of all lanthanoids and for the separation of fission products. The experimental experience gained in HPLC could be applied to the pre-concentration of isotopes in TLC. Both methods excellently supplemented each other in the separation of lanthanoids. (orig.) [de

  8. Lysogenic induction in Lex Al Escherichia coli mutants: characterization of the induction and prophage repressor influence

    International Nuclear Information System (INIS)

    Carvalho, R.E.S.

    1982-01-01

    SOS functions require new synthesis of protein and have been described as dependent on both the rec A and lex A genes. The induction of prophage was studied in bacterial strains lysogenic for a series of phages which synthesize different levels of repressor (λ, λ i m m 4 3 4 J and λ i m m 4 3 4 T ) and was compared to W-reactivation. Prophage induction was detected in lex Al mutants although at a slightly lower level and requiring two times longer when compared with wild-type. The optimum UV-dose for induction differed for each lysogenic strain and correlated with the level of repressor

  9. Between autobiography and reality : Popper's inductive years

    NARCIS (Netherlands)

    ter Hark, M.R.M.

    On the basis of his unpublished thesis 'Gewohnheit und Gesetzerlebnis in der Erziehung' (1926-7) a historical reconstruction is given of the genesis of Popper's ideas on induction and demarcation which differs radically from his own account in Unended quest. It is shown not only that he

  10. Free positioning for inductive wireless power system

    NARCIS (Netherlands)

    Waffenschmidt, E.

    2012-01-01

    In inductive wireless power transmission system a lateral displacement of the receiver coil to the transmitter coil leads to a change ofthe coupling factor and thus an unwanted variation of the power transfer. Here, an algorithm to determine the turn distribution to achieve homogeneous coupling

  11. Inductively coupled plasma- mass spectrometry. Chapter 13

    International Nuclear Information System (INIS)

    Mahalingam, T.R.

    1997-01-01

    Inductively Coupled Plasma - Mass Spectrometry (ICP-MS) is a new technique for elemental and isotopic analysis which is currently attracting a great deal of interest. This relatively new technique has found wide applications in different fields of research viz., nuclear, geological, biological and environmental sciences

  12. Induction accelerator development for heavy ion fusion

    International Nuclear Information System (INIS)

    Reginato, L.L.

    1993-05-01

    For approximately a decade, the Heavy Ion Fusion Accelerator Research (HIFAR) group at LBL has been exploring the use of induction accelerators with multiple beams as the driver for inertial fusion targets. Scaled experiments have investigated the transport of space charge dominated beams (SBTE), and the current amplification and transverse emittance control in induction linacs (MBE-4) with very encouraging results. In order to study many of the beam manipulations required by a driver and to further develop economically competitive technology, a proposal has been made in partnership with LLNL to build a 10 MeV accelerator and to conduct a series of experiments collectively called the Induction Linac System Experiments (ILSE). The major components critical to the ILSE accelerator are currently under development. We have constructed a full scale induction module and we have tested a number of amorphous magnetic materials developed by Allied Signal to establish an overall optimal design. The electric and magnetic quadrupoles critical to the transport and focusing of heavy ion beams are also under development The hardware is intended to be economically competitive for a driver without sacrificing any of the physics or performance requirements. This paper will concentrate on the recent developments and tests of the major components required by the ILSE accelerator

  13. Induction accelerator development for heavy ion fusion

    International Nuclear Information System (INIS)

    Reginato, L.L.

    1993-05-01

    For approximately a decade, the Heavy Ion Fusion Accelerator Research (HIFAR) group at LBL has been exploring the use of induction accelerators with multiple beams as the driver for inertial fusion targets. Scaled experiments have investigated the transport of space charge dominated beams (SBTE), and the current amplification and transverse emittance control in induction linacs (MBE-4) with very encouraging results. In order to study many of the beam manipulations required by a driver and to further develop economically competitive technology, a proposal has been made in partnership with LLNL to build a 10 MeV accelerator and to conduct a series of experiments collectively called the Induction Linac System Experiments (ILSE).The major components critical to the ILSE accelerator are currently under development. We have constructed a full scale induction module and we have tested a number of amorphous magnetic materials developed by Allied Signal to establish an overall optimal design. The electric and magnetic quadrupoles critical to the transport and focusing of heavy ion beams are also under development. The hardware is intended to be economically competitive for a driver without sacrificing any of the physics or performance requirements. This paper will concentrate on the recent developments and tests of the major components required by the ILSE accelerator

  14. Single phase induction motor with starting performance

    Energy Technology Data Exchange (ETDEWEB)

    Popescu, M.; Demeter, E. [Research Institute for Electrical Machines, ICPE-ME, Bucharest (Romania); Navrapescu, V. [University `Politehnica` Bucharest, Electrical Engineering Faculty Splaiul Independentei, Bucharest (Romania)

    1997-12-31

    The paper presents problems related to a special type of single phase induction motor. The main novelty consists in the use of a conducting (aluminium casted) shell distributed on the periferic region of the rotor. As a result the starting performance, as well as the rated ones, is much improved in comparison with the conventional construction. (orig.) 4 refs.

  15. The differential induction machine: Theory and performance

    Indian Academy of Sciences (India)

    feasibility of taking a turn. ... Thus the axial gap between the two rotors is also ... inductance than a normal machine due to the separating gap between the two rotors .... Crelerot O, Bernot F, Kauffmann J F 1993 Study of an electrical differential ...

  16. Adventitious shoots induction and plant regeneration from ...

    African Journals Online (AJOL)

    A highly efficient regeneration system is a prerequisite step for successful genetic transformation of watermelon cultivars (Citrullus lanatus L.). The objective of this study was to establish efficient in vitro plant regeneration for three watermelon cultivars. To achieve optimal conditions for adventitious shoot induction, the ...

  17. Recirculating induction accelerators for heavy ion fusion

    International Nuclear Information System (INIS)

    Barnard, J.J.; Deadrick, F.; Bangerter, R.O.

    1993-01-01

    We have recently completed a two-year study of recirculating induction heavy-ion accelerators (recirculators) as low-cost drivers for inertial-fusion-energy power plants. We present here a summary of that study and other recent work on recirculators

  18. High average-power induction linacs

    International Nuclear Information System (INIS)

    Prono, D.S.; Barrett, D.; Bowles, E.; Caporaso, G.J.; Chen, Yu-Jiuan; Clark, J.C.; Coffield, F.; Newton, M.A.; Nexsen, W.; Ravenscroft, D.; Turner, W.C.; Watson, J.A.

    1989-01-01

    Induction linear accelerators (LIAs) are inherently capable of accelerating several thousand amperes of ∼ 50-ns duration pulses to > 100 MeV. In this paper the authors report progress and status in the areas of duty factor and stray power management. These technologies are vital if LIAs are to attain high average power operation. 13 figs

  19. A model of annular linear induction pumps

    Energy Technology Data Exchange (ETDEWEB)

    Momozaki, Yoichi [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-10-27

    The present work explains how the magnetic field and the induced current are obtained when the distributed coils are powered by a 3 phase power supply.  From the magnetic field and the induced current, the thrust and the induction losses in the pump can be calculated to estimate the pump performance.

  20. Development of Chromatic Induction in Infancy

    Science.gov (United States)

    Okamura, Hiromi; Kanazawa, So; Yamaguchi, Masami K.

    2007-01-01

    The perception of colour in an embedded field is affected by the surround colour. This phenomenon is known as chromatic induction. In the present study we investigated whether the colour perception by infants aged 5-7 months could be affected by the surround colour. In Experiments 1 and 2 each stimulus was composed of an array of six squares in…

  1. High average-power induction linacs

    International Nuclear Information System (INIS)

    Prono, D.S.; Barrett, D.; Bowles, E.

    1989-01-01

    Induction linear accelerators (LIAs) are inherently capable of accelerating several thousand amperes of /approximately/ 50-ns duration pulses to > 100 MeV. In this paper we report progress and status in the areas of duty factor and stray power management. These technologies are vital if LIAs are to attain high average power operation. 13 figs

  2. Cylindrical Induction Melter Modicon Control System

    International Nuclear Information System (INIS)

    Weeks, G.E.

    1998-04-01

    In the last several years an extensive R ampersand D program has been underway to develop a vitrification system to stabilize Americium (Am) and Curium (Cm) inventories at SRS. This report documents the Modicon control system designed for the 3 inch Cylindrical Induction Melter (CIM)

  3. Inductive Reasoning about Causally Transmitted Properties

    Science.gov (United States)

    Shafto, Patrick; Kemp, Charles; Bonawitz, Elizabeth Baraff; Coley, John D.; Tenenbaum, Joshua B.

    2008-01-01

    Different intuitive theories constrain and guide inferences in different contexts. Formalizing simple intuitive theories as probabilistic processes operating over structured representations, we present a new computational model of category-based induction about causally transmitted properties. A first experiment demonstrates undergraduates'…

  4. Relations between Inductive Reasoning and Deductive Reasoning

    Science.gov (United States)

    Heit, Evan; Rotello, Caren M.

    2010-01-01

    One of the most important open questions in reasoning research is how inductive reasoning and deductive reasoning are related. In an effort to address this question, we applied methods and concepts from memory research. We used 2 experiments to examine the effects of logical validity and premise-conclusion similarity on evaluation of arguments.…

  5. early versus delayed induction of labour

    African Journals Online (AJOL)

    during labour versus 18 patients (52%) in the group that was induced .... (AMG) or a delayed induction group (DIG). Sealed .... Of the 7 CSs in the DIG, 3 were for fetal heart rate .... in mind that labour was never induced later than 48 hours.

  6. Inductance Calculations of Variable Pitch Helical Inductors

    Science.gov (United States)

    2015-08-01

    Electromagnetic Phenomena. July 2003;3:392–396. 2. Snow C. Formulas for computing capacitance and inductance. In: National bu- reau of standards circular 544...A PORWITZKY G THOMSON W UHLIG C WOLFE RDRL WMP C R MUDD RDRL WMP D J RUNYEON M KEELE N BRUCHEY R DONEY M

  7. Structure and Strength in Causal Induction

    Science.gov (United States)

    Griffiths, Thomas L.; Tenenbaum, Joshua B.

    2005-01-01

    We present a framework for the rational analysis of elemental causal induction--learning about the existence of a relationship between a single cause and effect--based upon causal graphical models. This framework makes precise the distinction between causal structure and causal strength: the difference between asking whether a causal relationship…

  8. Analysis of induction phenomena in thermonuclear experiments

    International Nuclear Information System (INIS)

    Deeds, W.E.; Dodd, C.V.

    1976-01-01

    Many of the problems involving transients induced by changing currents in the large coils of thermonuclear machines are identical to those arising in nondestructive testing by eddy currents. There are three chief methods used for calculating such induction phenomena: analytical boundary-value solutions, relaxation or iteration techniques, and model experiments. Some of the results obtained by each of these methods are described below

  9. Electromagnetic induction phenomena in plasma systems

    International Nuclear Information System (INIS)

    Karlovitz, B.

    1982-01-01

    The phenomenon of electromagnetic induction is considered in complex high temperature plasma systems. Thermal energy of such fully ionized plasma is really energy of the magnetic vortex fields surrounding the randomly moving ions and electrons. In an expanding plasma stream, moving across the containing magnetic field, random thermal motion of the ions and electrons is converted into ordered motion and thereby random magnetic energy of the plasma into magnetic energy of an ordered field. Consequently, in contrast to simple systems consisting of coils and magnets only, an expanding plasma stream can maintain net outflow of ordered magnetic energy from a closed volume for an indefinite length of time. Conversion of thermal energy of plasma into ordered magnetic energy by the thermodynamic expansion process leads to the expectation of a new induction phenomenon: the generation of a unidirectional induced electromotive force of unlimited duration, measured in a closed loop at rest relative to the magnetic field, by the expansion work of the plasma stream. No change is required in the differential form of Maxwell's equations for the existence of this induction phenomenon, only the definition of the concept of rate of change of magnetic flux needs to be modified in the macroscopic equations to correspond to the rate of flow of magnetic energy across a closed surface. An experimental test of the predicted induction phenomenon is proposed

  10. Teaching Inductive Reasoning in Primary Education.

    Science.gov (United States)

    de Koning, Els; Hamers, Jo H. M.; Sijtsma, Klaas; Vermeer, Adri

    2002-01-01

    Used a three-phase teaching procedure based on the development of metacognition to extend emphasis on inductive reasoning in primary education to Grades 3 and 4. Found that teachers could apply the programs as intended, but needed support to shift attention from reasoning product to reasoning process. Program learning effects indicated that better…

  11. Oral tolerance induction for human food allergy.

    Science.gov (United States)

    Noh, Geunwoong; Lee, Jae Ho

    2012-04-01

    Food allergies are classified as IgE-mediated and non-IgE mediated type. The number of successful reports of immunotherapy, namely tolerance induction for food allergy (TIFA) are increasing, bringing hope for meaningful positive and radical treatment of food allergy. Therapeutic characteristics of the clinical course in TIFA for NFA are different from TIFA for IFA. Cytokines including IL-10, TGF-β and IFN-γ and regulatory cells such as Treg and Breg, are involved in immune tolerance. IFN-γ has been used for tolerance induction of food allergy as an immunomodulatory biologics. A definitive distinction between IgE-mediated and non-IgE-mediated food allergies is absolutely essential for diagnostic and therapeutic purposes. Original SOTI using IFN-γ is more effective then conventional SOTI without IFN-γ. Especially, IFN-γ is absolutely necessary for the tolerance induction of NFA. This review highlights and updates the advances in the conceptual immunological background and the clinical characteristics of oral tolerance induction for food allergy.

  12. Tutorial: simulating chromatography with Microsoft Excel Macros.

    Science.gov (United States)

    Kadjo, Akinde; Dasgupta, Purnendu K

    2013-04-22

    Chromatography is one of the cornerstones of modern analytical chemistry; developing an instinctive feeling for how chromatography works will be invaluable to future generation of chromatographers. Specialized software programs exist that handle and manipulate chromatographic data; there are also some that simulate chromatograms. However, the algorithm details of such software are not transparent to a beginner. In contrast, how spreadsheet tools like Microsoft Excel™ work is well understood and the software is nearly universally available. We show that the simple repetition of an equilibration process at each plate (a spreadsheet row) followed by discrete movement of the mobile phase down by a row, easily automated by a subroutine (a "Macro" in Excel), readily simulates chromatography. The process is readily understood by a novice. Not only does this permit simulation of isocratic and simple single step gradient elution, linear or multistep gradients are also easily simulated. The versatility of a transparent and easily understandable computational platform further enables the simulation of complex but commonly encountered chromatographic scenarios such as the effects of nonlinear isotherms, active sites, column overloading, on-column analyte degradation, etc. These are not as easily simulated by available software. Views of the separation as it develops on the column and as it is seen by an end-column detector are both available in real time. Excel 2010™ also permits a 16-level (4-bit) color gradation of numerical values in a column/row; this permits visualization of a band migrating down the column, much as Tswett may have originally observed, but in a numerical domain. All parameters of relevance (partition constants, elution conditions, etc.) are readily changed so their effects can be examined. Illustrative Excel spreadsheets are given in the Supporting Information; these are easily modified by the user or the user can write his/her own routine. Copyright

  13. Phosphopeptide enrichment by immobilized metal affinity chromatography

    DEFF Research Database (Denmark)

    Thingholm, Tine E.; Larsen, Martin R.

    2016-01-01

    Immobilized metal affinity chromatography (IMAC) has been the method of choice for phosphopeptide enrichment prior to mass spectrometric analysis for many years and it is still used extensively in many laboratories. Using the affinity of negatively charged phosphate groups towards positively...... charged metal ions such as Fe3+, Ga3+, Al3+, Zr4+, and Ti4+ has made it possible to enrich phosphorylated peptides from peptide samples. However, the selectivity of most of the metal ions is limited, when working with highly complex samples, e.g., whole-cell extracts, resulting in contamination from...

  14. Undergraduate physics laboratory: Electrophoresis in chromatography paper

    Science.gov (United States)

    Hyde, Alexander; Batishchev, Oleg

    2015-12-01

    An experiment studying the physical principles of electrophoresis in liquids was developed for an undergraduate laboratory. We have improved upon the standard agarose gel electrophoresis experimental regime with a straightforward and cost-effective procedure, in which drops of widely available black food coloring were separated by electric field into their dye components on strips of chromatography paper soaked in a baking soda/water solution. Terminal velocities of seven student-safe dyes were measured as a function of the electric potential applied along the strips. The molecular mobility was introduced and calculated by analyzing data for a single dye. Sources of systematic and random errors were investigated.

  15. Gas chromatography of alkylphosphonic and dialkylphosphinic acids

    International Nuclear Information System (INIS)

    Gasco, L.; Barrera, R.; Ramirez, A.; Martin Munoz, N.

    1978-01-01

    After carrying out an optimization study on the separation conditions for the TMS-derivatives, of the hexyl-, cyclohexyl-, heptyl-, and octyl-phosphonic acids; dihexyl-, dicyclohexyl-, heptyl-, and octyl-phosphinic acids, and dioctylphosphine oxide, their retention indices (I) at two temperatures and on the 0V-1 and 0V-17 stationary phase were determined. Correlations between I and molecular structure were established. Calibration factors of these compounds in the flame ionization detector were studied, and the results analized taking into account the variables afecting the quantitative results. These results were unbiased but they had a lower precission than usually achieveble in gas chromatography. (author)

  16. Quantitative analysis of deuterium by gas chromatography

    International Nuclear Information System (INIS)

    Isomura, Shohei; Kaetsu, Hayato

    1981-01-01

    An analytical method for the determination of deuterium concentration in water and hydrogen gas by gas chromatography is described. HD and D 2 in a hydrogen gas sample were separated from H 2 by a column packed with Molecular Sieve 13X, using extra pure hydrogen gas as carrier. A thermal conductivity detector was used. Concentrations of deuterium were determined by comparison with standard samples. The error inherent to the present method was less a 1% on the basis of the calibration curves obtained with the standard samples. The average time required for the analysis was about 3 minutes. (author)

  17. HDT mixtures treatment strategies by gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Laquerbe, C.; Contreras, S.; Demoment, J. [Commissariat a l' Energie Atomique - CEA/Valduc, F-21121 Is sur Tille (France)

    2008-07-15

    Gas phase chromatographic processes are of interest for the separation of hydrogen isotopes from an HDT mixture. For a certain quantity, they are very competitive and present several benefits. Nevertheless no active packing material allows to have simultaneously good enrichment performances for tritium production and high decontamination capabilities for HD gases. The influence of the packing material is first described in this article. Then two specific processes (TCAP and Reverse Chromatography), each well adapted to perform one target, are presented. Finally, the problematic to propose an optimized treatment scheme associating these two processes is formulated. (authors)

  18. HDT mixtures treatment strategies by gas chromatography

    International Nuclear Information System (INIS)

    Laquerbe, C.; Contreras, S.; Demoment, J.

    2008-01-01

    Gas phase chromatographic processes are of interest for the separation of hydrogen isotopes from an HDT mixture. For a certain quantity, they are very competitive and present several benefits. Nevertheless no active packing material allows to have simultaneously good enrichment performances for tritium production and high decontamination capabilities for HD gases. The influence of the packing material is first described in this article. Then two specific processes (TCAP and Reverse Chromatography), each well adapted to perform one target, are presented. Finally, the problematic to propose an optimized treatment scheme associating these two processes is formulated. (authors)

  19. Course on Advanced Analytical Chemistry and Chromatography

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov; Fristrup, Peter; Nielsen, Kristian Fog

    2011-01-01

    Methods of analytical chemistry constitute an integral part of decision making in chemical research, and students must master a high degree of knowledge, in order to perform reliable analysis. At DTU departments of chemistry it was thus decided to develop a course that was attractive to master...... students of different direction of studies, to Ph.D. students and to professionals that need an update of their current state of skills and knowledge. A course of 10 ECTS points was devised with the purpose of introducing students to analytical chemistry and chromatography with the aim of including theory...

  20. Assessment and modeling of inductive and non-inductive scenarios for ITER

    International Nuclear Information System (INIS)

    Boucher, D.; Vayakis, G.; Moreau, D.

    1999-01-01

    This paper presents recent developments in modeling and simulations of ITER performances and scenarios. The first part presents an improved modeling of coupled divertor/main plasma operation including the simulation of the measurements involved in the control loop. The second part explores the fusion performances predicted under non-inductive operation with internal transport barrier. The final part covers a detailed scenario for non-inductive operation using a reverse shear configuration with lower hybrid and fast wave current drive. (author)

  1. Use of chelating agents as immovable phase in extraction chromatography

    International Nuclear Information System (INIS)

    Sebesta, F.

    1978-01-01

    Extraction chromatography using chelating agents is reviewed. The theory of element extraction by chelating agents and factors influencing this process (pH, extracting agent concentration in organic phase, masking agent concentration in aqueous phase) are briefly considered. The effect of kinetic factors on the extraction chromatography process is discussed. Ways of preparing columns are emphasized. Examples of using chelating reagents in various extraction chromatography systems are given. β-Diketones, oximes, hydroxamic acids, dithizon, diethyl dithiocarbamic acid are chosen as chelating agents

  2. [High-performance liquid-liquid chromatography in beverage analysis].

    Science.gov (United States)

    Bricout, J; Koziet, Y; de Carpentrie, B

    1978-01-01

    Liquid liquid chromatography was performed with columns packed with stationary phases chemically bonded to silica microparticules. These columns show a high efficiency and are used very easily. Flavouring compounds like aromatic aldehydes which have a low volatility were analyzed in brandy using a polar phase alkylnitrile. Sapid substances like amarogentin in Gentiana lutea or glyryrrhizin in Glycyrrhiza glabra were determined by reversed phase chromatography. Finally ionizable substances like synthetic dyes can be analyzed by paired ion chromatography witha non polar stationary phase.

  3. Determination of rare earth elements by liquid chromatographic separation using inductively coupled plasma mass spectrometric detection

    International Nuclear Information System (INIS)

    Braverman, D.S.

    1992-01-01

    High-performance liquid chromatography (HPLC) is used to separate the rare earth elements (REEs) prior to detection by inductively coupled plasma mass spectrometry (ICP-MS). The use of HPLC-ICP-MS in series combines the separation power and speed of HPLC with the sensitivity, isotopic selectivity and speed of ICP-MS. The detection limits for the REEs are in the sub-ng ml -1 range and the response is linear over four orders of magnitude. A preliminary comparison of isotope dilution and external standard results for the determination of REEs in National Institute of Standards and Technology (NIST) Standard Reference Material (SRM 1633a) Fly Ash is presented. (author)

  4. Inductively coupled plasma emission spectrometric detection of simulated high performance liquid chromatographic peaks

    International Nuclear Information System (INIS)

    Fraley, D.M.; Yates, D.; Manahan, S.E.

    1979-01-01

    Because of its multielement capability, element-specificity, and low detection limits, inductively coupled plasma optical emission spectrometry (ICP) is a very promising technique for the detection of specific elemental species separated by high performance liquid chromatography (HPLC). This paper evaluated ICP as a detector for HPLC peaks containing specific elements. Detection limits for a number of elements have been evaluated in terms of the minimum detectable concentration of the element at the chromatographic peak maximum. The elements studies were Al, As, B, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Na, Ni, P, Pb, Sb, Se, Sr, Ti, V, and Zn. In addition, ICP was compared with atomic absorption spectrometry for the detection of HPLC peaks composed of EDTA and NTA chelates of copper. Furthermore, ICP was compared to uv solution absorption for the detection of copper chelates. 6 figures, 4 tables

  5. Plutonium bioassay by inductively coupled plasma mass spectrometry ICP/MS

    International Nuclear Information System (INIS)

    Wyse, E.J.; Fisher, D.R.

    1993-04-01

    The determination of plutonium in urine poses several analytical challenges, e.g., detectability, matrix, etc. We have investigated the feasibility of analyzing plutonium in processed urine by inductively coupled plasma mass spectrometry (ICP/MS). The urine samples are first spiked with 244 Pu as a tracer and internal standard, then processed by co-precipitation and column chromatography using TRU-Spec trademark, an extraction resin. By enhancing ICP/MS detection capabilities via improved sample introduction and data acquisition efficiencies, an instrumental detection limit of 5 to 50 fg (0.3 to 3 fCi for 239 pu) is typically obtained, depending on the desired degree of quantitation. A brief summary of the analytical method as well as the basis for measuring radionuclides by ICP/MS are submitted; the separation procedure, methods of sample introduction, and data acquisition techniques are then highlighted

  6. Determination of long-lived actinides in soil leachates by inductively coupled plasma: Mass spectrometry

    International Nuclear Information System (INIS)

    Crain, J.S.; Smith, L.L.; Yaeger, J.S.; Alvarado, J.A.

    1994-01-01

    Inductively coupled plasma -- mass spectrometry (ICP-MS) was used to concurrently determine multiple long-lived (t 1/2 > 10 4 y) actinide isotopes in soil samples. Ultrasonic nebulization was found to maximize instrument sensitivity. Instrument detection limits for actinides in solution ranged from 50 mBq L -1 ( 239 Pu) to 2 μBq L -1 ( 235 U) Hydride adducts of 232 Th and 238 U interfered with the determinations of 233 U and 239 Pu; thus, extraction chromatography was, used to eliminate the sample matrix, concentrate the analytes, and separate uranium from the other actinides. Alpha spectrometric determinations of 230 Th, 239 Pu, and the 234 U/ 238 U activity ratio in soil leachates compared well with ICP-MS determinations; however, there were some small systematic differences (ca. 10%) between ICP-MS and a-spectrometric determinations of 234 U and 238 U activities

  7. Optimizing separations in online comprehensive two‐dimensional liquid chromatography

    Science.gov (United States)

    Gargano, Andrea F.G.; Schoenmakers, Peter J.

    2017-01-01

    Abstract Online comprehensive two‐dimensional liquid chromatography has become an attractive option for the analysis of complex nonvolatile samples found in various fields (e.g. environmental studies, food, life, and polymer sciences). Two‐dimensional liquid chromatography complements the highly popular hyphenated systems that combine liquid chromatography with mass spectrometry. Two‐dimensional liquid chromatography is also applied to the analysis of samples that are not compatible with mass spectrometry (e.g. high‐molecular‐weight polymers), providing important information on the distribution of the sample components along chemical dimensions (molecular weight, charge, lipophilicity, stereochemistry, etc.). Also, in comparison with conventional one‐dimensional liquid chromatography, two‐dimensional liquid chromatography provides a greater separation power (peak capacity). Because of the additional selectivity and higher peak capacity, the combination of two‐dimensional liquid chromatography with mass spectrometry allows for simpler mixtures of compounds to be introduced in the ion source at any given time, improving quantitative analysis by reducing matrix effects. In this review, we summarize the rationale and principles of two‐dimensional liquid chromatography experiments, describe advantages and disadvantages of combining different selectivities and discuss strategies to improve the quality of two‐dimensional liquid chromatography separations. PMID:29027363

  8. Optimizing separations in online comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Pirok, Bob W J; Gargano, Andrea F G; Schoenmakers, Peter J

    2018-01-01

    Online comprehensive two-dimensional liquid chromatography has become an attractive option for the analysis of complex nonvolatile samples found in various fields (e.g. environmental studies, food, life, and polymer sciences). Two-dimensional liquid chromatography complements the highly popular hyphenated systems that combine liquid chromatography with mass spectrometry. Two-dimensional liquid chromatography is also applied to the analysis of samples that are not compatible with mass spectrometry (e.g. high-molecular-weight polymers), providing important information on the distribution of the sample components along chemical dimensions (molecular weight, charge, lipophilicity, stereochemistry, etc.). Also, in comparison with conventional one-dimensional liquid chromatography, two-dimensional liquid chromatography provides a greater separation power (peak capacity). Because of the additional selectivity and higher peak capacity, the combination of two-dimensional liquid chromatography with mass spectrometry allows for simpler mixtures of compounds to be introduced in the ion source at any given time, improving quantitative analysis by reducing matrix effects. In this review, we summarize the rationale and principles of two-dimensional liquid chromatography experiments, describe advantages and disadvantages of combining different selectivities and discuss strategies to improve the quality of two-dimensional liquid chromatography separations. © 2017 The Authors. Journal of Separation Science published by WILEY-VCH Verlag GmbH & Co. KGaA.

  9. Total Arsenic Determination and Speciation in Infant Food Products by Ion Chromatography Inductively Coupled Plasma Mass Spectrometry

    Science.gov (United States)

    Health risk associated with dietary arsenic intake may be different for infants and adults. Seafood is the main contributor to arsenic intake for adults while terrestrial-based food is the primary source for infants. Processed infant food products such as rice-based cereals, mi...

  10. Factors influencing callus induction and plant regeneration of ...

    African Journals Online (AJOL)

    ajl yemi

    2012-01-12

    ). Effect of basal medium on callus induction and plant regeneration. Three different kinds of basal mediums (MS, N6 and SH) were used to investigate their effects on callus induction and regeneration. Significant differences ...

  11. Sliding Mode Control of Induction Motor Phase Currents

    DEFF Research Database (Denmark)

    Hansen, R.B.; Hattel, T.; Bork, J

    1995-01-01

    Sliding mode control of induction motor phase currents are investigated through development of two control concepts.......Sliding mode control of induction motor phase currents are investigated through development of two control concepts....

  12. Enhancement of callus induction and regeneration efficiency from ...

    African Journals Online (AJOL)

    Administrator

    2011-09-05

    Sep 5, 2011 ... efficiency from embryo cultures of Datura stramonium ... cycle (callus induction and plant regeneration) for Datura stramonium by adjusting carbon sources and ... induction and development in various species, it is not.

  13. ORIGINAL ARTICLES Labour induction at term - a randomised trial ...

    African Journals Online (AJOL)

    with or without the injection of saline solution or prostaglandins ... More analgesia was used in the Foley catheter/misoprostol ... Eligible women with clinical indications for labour induction at .... Meconium .... on the process of labour induction.

  14. Inductive bituminous mortar with steel and aluminum fibers

    NARCIS (Netherlands)

    Pavlatos, N.; Apostolidis, P.; Scarpas, Athanasios; Liu, X.; van de Ven, M.F.C.

    2018-01-01

    This research presents the implementation of a finite element model analysis for assessing the potential of utilizing alternative fibers for the development of inductive bituminous mixes with lower total weight, higher resistance against corrosion, and sufficient induction heating efficiency.

  15. Self-Tuning Speed Regulator for CVC Induction Motor Drive

    DEFF Research Database (Denmark)

    Bidstrup, N.; Rasmussen, Henrik; Knudsen, Torben

    1994-01-01

    A self-tuning speed regulator for a current vector controlled induction motor drive has been designed.......A self-tuning speed regulator for a current vector controlled induction motor drive has been designed....

  16. Liquid chromatography - mass spectrometry analysis of pharmaceuticals

    International Nuclear Information System (INIS)

    Macasek, F.

    2003-01-01

    The drugs represent mostly non-volatile and thermally labile solutes, often available only in small amounts like it is in case of radiopharmaceuticals. Therefor, the favourable separation techniques for such compounds are HPLC, capillary electrophoresis and also TLC 1. Liquid chromatography with mass spectrometric detector (LC/MS) is especially powerful for their microanalysis. Mass spectrometry separating the ions in high vacuum was presumably used as detector for gas chromatography effluent but the on-line coupling with liquid eluant flow 0.1-1 mL/min is far more challenging. New types of ion sources were constructed for simultaneous removal of solvent and ionisation of solutes at atmospheric pressure (API). At present, a relatively wide choice of successfully designed commercial equipment is available either for small organic molecules and larger biomolecules (Perkin-Elmer, Agilent, Jeol, Bruker Daltonics, ThermoQuest, Shimadzu). The features of the LC/MS systems are presented. LC/MS as a new quality control tool for [F-18]fluorodeoxyglucose (FDG) radiopharmaceutical, which has became the most spread radiopharmaceutical for positron emission tomography (PET), was proposed. Other applications of the LC/MS are reviewed. (author)

  17. Alternatives to Chromatography in Plant Breeding

    Directory of Open Access Journals (Sweden)

    Keusgen, Michael

    2016-07-01

    Full Text Available Wild plants were taken into cultivation because of special features. Usually, medicinal plants or spices show distinct secondary metabolites combined with a specific pattern of these compounds. Typically, chromatographic methods like gas chromatography (GC or high performance liquid chromatography (HPLC were applied as standard methods for a meaningful analysis of secondary metabolites. However, these methods are labor and time intensive. In the breeding process, usually numerous single plants have to be analyzed and therefore, high throughput methods are required. In this article, some examples for alternative strategies are given. Besides spectroscopic methods like near infrared (NIR, also biosensoric approaches should be considered. For instance, several enzymes can oxidize or hydrolyze secondary metabolites in dependence of their functional groups. Polyphenols can be determined by laccases. Polyphenols like catechins and flavonoids contribute to the bioactivity of many medicinal plants. Also cysteine sulfoxides, which are typical for Allium species like garlic and onions, can be enzymatically determined with high specificity. Finally, toxic cyanogenic glycosides can be quantified by the enzyme cyanidase.

  18. Gas chromatography/plasma spectrometry - an important analytical tool for elemental speciation studies

    International Nuclear Information System (INIS)

    Wuilloud, Jorgelina C.A.; Wuilloud, Rodolfo G.; Vonderheide, Anne P.; Caruso, Joseph A.

    2004-01-01

    In this review, a full discussion and update of the state-of-the-art of gas chromatography (GC) coupled to all known plasma spectrometers is presented. A brief introductive discussion of the advantages and disadvantages of GC-plasma interfaces, as well as types of plasmas and mass spectrometers, is given. The plasma-based techniques covered include inductively coupled plasma mass spectrometry (ICP-MS) microwave-induced plasma optical emission spectrometry (MIP-OES), and inductively coupled plasma optical emission spectrometry (ICP-OES). Also, different variants of plasma sources, such as low power plasmas and glow discharge (GD) sources, are described and compared with respect to their capabilities in elemental speciation. Recent advances and alternative mass analyzers (collision/reaction cell; time-of-flight; double-focusing sector field) are also mentioned. Different aspects of the GC-plasma coupling are discussed with particular attention to the applications of these hyphenated techniques to the analysis of elemental species. Additionally, classical and modern sample preparation methods, including extraction and/or preconcentration and derivatization reactions, are presented and evaluated

  19. Applications of plasma spectrometry and high performance liquid chromatography in environmental and food science

    International Nuclear Information System (INIS)

    Iordache, Andreea-Maria; Biraruti, Elisabeta-Irina; Ionete, Roxana-Elena

    2008-01-01

    Full text: Plasma spectrometry has many applications in food science in analysis of a wide range of samples in the food chain. Food science in the broadest sense can be extended to include soil chemistry, plant uptake and, at the other end of the food chain, studies into the metabolic fate of particular elements or elemental species when the foods are consumed by humans or animals. Inductively Coupled Plasma Mass Spectrometry allows multi-element measurements of most elements in the periodic table. A very sensitive analytical technique for trace analysis of samples can be performed by inductively plasma mass spectrometer with quadrupolar detector using ultrasonic nebulization. High Performance Liquid Chromatography (HPLC) is an analytical technique for the separation and determination of organic and inorganic solutes in any samples especially biological, pharmaceutical, food, environmental. The present paper emphasizes that the future tendencies HPLC-ICP-MS is often the preferred analytical technique for these applications due to the simplicity of the coupling between the HPLC and ICP-MS Varian 820 using ultrasonic nebulization, potential for on-line separations with high species specificity and the capability for optimum limits of detection without the necessity of using complex hydride generation mechanisms. (authors)

  20. The weight of flash chromatography: A tool to predict its mass intensity from thin-layer chromatography

    Directory of Open Access Journals (Sweden)

    Freddy Pessel

    2016-11-01

    Full Text Available Purification by flash chromatography strongly impacts the greenness of a process. Unfortunately, due to the lack of the relevant literature data, very often this impact cannot be assessed thus preventing the comparison of the environmental factors affecting the syntheses. We developed a simple mathematical approach to evaluate the minimum mass intensity of flash chromatography from the retention factor values determined by thin-layer chromatography.

  1. Rule Induction-Based Knowledge Discovery for Energy Efficiency

    OpenAIRE

    Chen, Qipeng; Fan, Zhong; Kaleshi, Dritan; Armour, Simon M D

    2015-01-01

    Rule induction is a practical approach to knowledge discovery. Provided that a problem is developed, rule induction is able to return the knowledge that addresses the goal of this problem as if-then rules. The primary goals of knowledge discovery are for prediction and description. The rule format knowledge representation is easily understandable so as to enable users to make decisions. This paper presents the potential of rule induction for energy efficiency. In particular, three rule induct...

  2. Modeling of the Inductance of a Blumlein Circuit Spark Gap

    International Nuclear Information System (INIS)

    Aboites, V; Rendón, L; Hernández, A I; Valdés, E

    2015-01-01

    In this paper we present an analysis of the time-varying inductance in the spark gap of a Blumlein circuit. We assume several mathematical expressions to describe the inductance and compare theoretical and computational calculations with experimental results. The time-varying inductance is approximated by a constant, a straight line and two parables which differ in their concavity. This is the first time to our knowledge, in which the time-varying ignition inductance of a nitrogen laser is modeled

  3. Proton induction linacs as high-intensity neutron sources

    International Nuclear Information System (INIS)

    Keefe, D.; Hoyer, E.

    1981-01-01

    Proton induction linacs are explored as high intensity neutron sources. The induction linac - concept, properties, experience with electrons, and possibilities - and its limitations for accelerating ions are reviewed. A number of proton induction linac designs are examined with the LIACEP program and general conclusions are given. Results suggest that a proton induction accelerator of the lowest voltage, consistent with good neutron flux, is preferred and could well be cost competitive with the usual rf linac/storage ring designs. (orig.)

  4. Meta-learning in decision tree induction

    CERN Document Server

    Grąbczewski, Krzysztof

    2014-01-01

    The book focuses on different variants of decision tree induction but also describes  the meta-learning approach in general which is applicable to other types of machine learning algorithms. The book discusses different variants of decision tree induction and represents a useful source of information to readers wishing to review some of the techniques used in decision tree learning, as well as different ensemble methods that involve decision trees. It is shown that the knowledge of different components used within decision tree learning needs to be systematized to enable the system to generate and evaluate different variants of machine learning algorithms with the aim of identifying the top-most performers or potentially the best one. A unified view of decision tree learning enables to emulate different decision tree algorithms simply by setting certain parameters. As meta-learning requires running many different processes with the aim of obtaining performance results, a detailed description of the experimen...

  5. 5 KV low-induction capactitor battery

    International Nuclear Information System (INIS)

    Babalin, A.I.; Burtsev, V.A.; Emel'yanov, A.I.; Kunaev, G.T.; Ovsyannikov, V.A.; Zhmodikov, B.S.

    1981-01-01

    A 1.2 MJ capacitor battery is developed and constructed for creating strong magnetic fields for thermonuclear facilities, pumping of laser active media. The capacitor battery is assembled of 512 IMU5-150 and 128 IS5-200 capacitors. The design is based on division of the capacitor battery in 40 sections. The energy commutation is performed by air spark gaps of the trigatron type with 24 to 60 nH inductance. Electromagnetic switches are made on the base of the EP 41V-33 relay. A low-induction generator is developed for spark gap ignition. The capacitor sections, each of them comprising 16 capacitors, and loadings are switched-in either by means of cables or flat lines. Accidents were not observed during operation of 20 sections of the capacitor battery (capacitors break-down, break of polyethylene isolation, deformation of tyre-wires) [ru

  6. Dragon-I Linear Induction Electron Accelerator

    International Nuclear Information System (INIS)

    Ding Bonan; Deng Jianjun; Wang Huacen; Cheng Nian'an; Dai Guangsen; Zhang Linwen; Liu Chengjun; Zhang Wenwei; Li Jin; Zhang Kaizhi

    2005-01-01

    Dragon-I is a linear induction electron accelerator. This facility consists of a 3.6 MeV injector, 38 meter beam transport line and 16 MeV induction accelerator powered by high voltage generators, including 8 Marx generators and 48 Blumlein lines. This paper describes the physics design, development and experimental results of Dragon-I. The key technology is analyzed in the accelerator development, and the design requirements and operation of the major subsystems are presented. The experimental results show Dragon-I generates an 18-20 MeV, 2.5 kA, 70 ns electron beam. The X-ray spot size is about 1.2 mm and dose level about 0.103 C/kg at 1 meter. (authors)

  7. Reverse engineering of inductive fault current limiters

    Energy Technology Data Exchange (ETDEWEB)

    Pina, J M; Neves, M Ventim; Rodrigues, A L [Centre of Technology and Systems Faculdade de Ciencias e Tecnologia, Nova University of Lisbon Monte de Caparica, 2829-516 Caparica (Portugal); Suarez, P; Alvarez, A, E-mail: jmmp@fct.unl.p [' Benito Mahedero' Group of Electrical Applications of Superconductors Escuela de IngenierIas Industrials, University of Extremadura Avenida de Elvas s/n, 06006 Badajoz (Spain)

    2010-06-01

    The inductive fault current limiter is less compact and harder to scale to high voltage networks than the resistive one. Nevertheless, its simple construction and mechanical robustness make it attractive in low voltage grids. Thus, it might be an enabling technology for the advent of microgrids, low voltage networks with dispersed generation, controllable loads and energy storage. A new methodology for reverse engineering of inductive fault current limiters based on the independent analysis of iron cores and HTS cylinders is presented in this paper. Their electromagnetic characteristics are used to predict the devices' hysteresis loops and consequently their dynamic behavior. Previous models based on the separate analysis of the limiters' components were already derived, e.g. in transformer like equivalent models. Nevertheless, the assumptions usually made may limit these models' application, as shown in the paper. The proposed methodology obviates these limitations. Results are validated through simulations.

  8. SHIVA star inductive pulse compression system

    International Nuclear Information System (INIS)

    Reinovsky, R.E.; Baker, W.L.; Chen, Y.G.; Holmes, J.; Lopez, E.

    1983-01-01

    The SHIVA star capacitor bank, a 120 kv parallel bank storing 9.5 mj with a short circuit current of almost 90 ma, at the AFWL is the world's highest energy, fast capacitor bank. The approximately 3 microsecond short circuit risetime is shortened by an inductive store/opening switch power conditioning system in which a total inductance of about 10 nh is charged with 35 ma currents. Electrically exploded conductor (fuse) opening switches are employed to interrupt the current in a few hundred nanoseconds to deliver a fast rising current to the load. The system is in operation at the AFWL and is used for a variety of plasma physics experiments. Performance of the bank and pulse compression system are discussed

  9. Reverse engineering of inductive fault current limiters

    International Nuclear Information System (INIS)

    Pina, J M; Neves, M Ventim; Rodrigues, A L; Suarez, P; Alvarez, A

    2010-01-01

    The inductive fault current limiter is less compact and harder to scale to high voltage networks than the resistive one. Nevertheless, its simple construction and mechanical robustness make it attractive in low voltage grids. Thus, it might be an enabling technology for the advent of microgrids, low voltage networks with dispersed generation, controllable loads and energy storage. A new methodology for reverse engineering of inductive fault current limiters based on the independent analysis of iron cores and HTS cylinders is presented in this paper. Their electromagnetic characteristics are used to predict the devices' hysteresis loops and consequently their dynamic behavior. Previous models based on the separate analysis of the limiters' components were already derived, e.g. in transformer like equivalent models. Nevertheless, the assumptions usually made may limit these models' application, as shown in the paper. The proposed methodology obviates these limitations. Results are validated through simulations.

  10. Multichannel simultaneous magnetic induction measurement system (MUSIMITOS)

    International Nuclear Information System (INIS)

    Steffen, Matthias; Leonhardt, Steffen; Heimann, Konrad; Bernstein, Nina

    2008-01-01

    Non-contact heart and lung activity monitoring would be a desirable supplement to conventional monitoring techniques. Based on the potential of non-contact magnetic induction measurements, requirements for an adequate monitoring system were estimated. This formed the basis for the development of the presented extendable multichannel simultaneous magnetic induction measurement system (MUSIMITOS). Special focus was given to the dynamic behaviour and simultaneous multichannel measurements, so that the system allows for up to 14 receiver coils working simultaneously at 6 excitation frequencies. Moreover, a real-time software concept for online signal processing visualization in combination with a fast software demodulation is presented. Finally, first steps towards a clinical application are pointed out and technical performance as well as first in vivo measurements are presented. This paper covers some aspects previously presented in Steffen and Leonhardt (2007 Proc. 13th Int. Conf. on Electrical Bioimpedance and the 8th Conf. on Electrical Impedance Tomography, Graz 2007)

  11. Long range inductive power transfer system

    International Nuclear Information System (INIS)

    Lawson, James; Pinuela, Manuel; Yates, David C; Lucyszyn, Stepan; Mitcheson, Paul D

    2013-01-01

    We report upon a recently developed long range inductive power transfer system (IPT) designed to power remote sensors with mW level power consumption at distances up to 7 m. In this paper an inductive link is established between a large planar (1 × 1 m) transmit coil (Tx) and a small planer (170 × 170 mm) receiver coil (Rx), demonstrating the viability of highly asymmetrical coil configurations that real-world applications such as sensor networks impose. High Q factor Tx and Rx coils required for viable power transfer efficiencies over such distances are measured using a resonant method. The applicability of the Class-E amplifier in very low magnetic coupling scenarios and at the high frequencies of operation required for high Q operation is demonstrated by its usage as the Tx coil driver

  12. Mutation induction by ion beams in plants

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Atsushi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    2001-03-01

    The effect of ion beams such as C, He, and Ne ions was investigated on the mutation induction in plants with the expectation that ion beams of high linear energy transfer (LET) can frequently produce large DNA alternation such as inversion, translocation and large deletion rather than point mutation. Mutation frequency was investigated using Arabidopsis visible phenotype loci and was 8 to 33 fold higher for 220 MeV carbon ions than for electrons. Mutation spectrum was investigated on the flower color of chrysanthemum cv to find that flower mutants induced by ion beams show complex and stripe types rather than single color. Polymerase chain reaction analysis was performed to investigate DNA alteration of mutations. In conclusion, the characteristics of ion beams for the mutation induction are 1) high frequency, 2) broad mutation spectrum, and 3) novel mutants. (S. Ohno)

  13. Mutation induction by ion beams in plants

    International Nuclear Information System (INIS)

    Tanaka, Atsushi

    2001-01-01

    The effect of ion beams such as C, He, and Ne ions was investigated on the mutation induction in plants with the expectation that ion beams of high linear energy transfer (LET) can frequently produce large DNA alternation such as inversion, translocation and large deletion rather than point mutation. Mutation frequency was investigated using Arabidopsis visible phenotype loci and was 8 to 33 fold higher for 220 MeV carbon ions than for electrons. Mutation spectrum was investigated on the flower color of chrysanthemum cv to find that flower mutants induced by ion beams show complex and stripe types rather than single color. Polymerase chain reaction analysis was performed to investigate DNA alteration of mutations. In conclusion, the characteristics of ion beams for the mutation induction are 1) high frequency, 2) broad mutation spectrum, and 3) novel mutants. (S. Ohno)

  14. Backstepping Strategy for Induction Motor Control

    DEFF Research Database (Denmark)

    Rasmussen, Henrik; Vadstrup, P.; Børsting, H.

    2000-01-01

    Using backstepping, which is a recursive nonlinear design method, a novel approach to control of induction motors is developed. The resulting scheme leads to a nonlinear controller for the torque and the amplitude of the field. A combination of nonlinear damping and observer backstepping with a s......Using backstepping, which is a recursive nonlinear design method, a novel approach to control of induction motors is developed. The resulting scheme leads to a nonlinear controller for the torque and the amplitude of the field. A combination of nonlinear damping and observer backstepping...... with a simple flux observer is used in the design. Assuming known motor parameters the design achieves stability with guaranteed region of attraction. It is also shown how a conventional field oriented controller may be obtained by omitting parts of the nonlinear controller....

  15. PULSAR: an inductive pulse power source

    International Nuclear Information System (INIS)

    Cnare, E.C.; Brooks, W.P.; Cowan, M.

    1979-01-01

    The PULSAR concept of inductive pulsed power source uses a flux-compressing metallic or plasma armature rather than a fast opening switch to transfer magnetic flux to a load. The inductive store may be a relatively unsophisticated dc superconducting magnet since no magnetic energy is taken from it, and no large current transients are induced in it. Initial experimental efforts employed either expendable or reusable metallic armatures with a 200 kJ, 450 mm diameter superconducting magnet. Attention is now being focused on the development of much faster plasma armatures for use in larger systems of one and two meters diameter. Techniques used to generate the required high magnetic Reynolds number flow will be described and initial experimental results will be presented

  16. Calculation of Leakage Inductance for High Frequency Transformers

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Jun, Zhang; Hurley, William Gerard

    2015-01-01

    Frequency dependent leakage inductance is often observed. High frequency eddy current effects cause a reduction in leakage inductance. The proximity effect between adjacent layers is responsible for the reduction of leakage inductance. This paper gives a detailed analysis of high frequency leakag...

  17. Cognitive Trait Modelling: The Case of Inductive Reasoning Ability

    Science.gov (United States)

    Kinshuk, Taiyu Lin; McNab, Paul

    2006-01-01

    Researchers have regarded inductive reasoning as one of the seven primary mental abilities that account for human intelligent behaviours. Researchers have also shown that inductive reasoning ability is one of the best predictors for academic performance. Modelling of inductive reasoning is therefore an important issue for providing adaptivity in…

  18. A Logic Programming Testbed for Inductive Thought and Specification.

    Science.gov (United States)

    Neff, Norman D.

    This paper describes applications of logic programming technology to the teaching of the inductive method in computer science and mathematics. It discusses the nature of inductive thought and its place in those fields of inquiry, arguing that a complete logic programming system for supporting inductive inference is not only feasible but necessary.…

  19. Rapid induction of lipid droplets in Chlamydomonas reinhardtii and Chlorella vulgaris by Brefeldin A.

    Directory of Open Access Journals (Sweden)

    Sangwoo Kim

    Full Text Available Algal lipids are the focus of intensive research because they are potential sources of biodiesel. However, most algae produce neutral lipids only under stress conditions. Here, we report that treatment with Brefeldin A (BFA, a chemical inducer of ER stress, rapidly triggers lipid droplet (LD formation in two different microalgal species, Chlamydomonas reinhardtii and Chlorella vulgaris. LD staining using Nile red revealed that BFA-treated algal cells exhibited many more fluorescent bodies than control cells. Lipid analyses based on thin layer chromatography and gas chromatography revealed that the additional lipids formed upon BFA treatment were mainly triacylglycerols (TAGs. The increase in TAG accumulation was accompanied by a decrease in the betaine lipid diacylglyceryl N,N,N-trimethylhomoserine (DGTS, a major component of the extraplastidic membrane lipids in Chlamydomonas, suggesting that at least some of the TAGs were assembled from the degradation products of membrane lipids. Interestingly, BFA induced TAG accumulation in the Chlamydomonas cells regardless of the presence or absence of an acetate or nitrogen source in the medium. This effect of BFA in Chlamydomonas cells seems to be due to BFA-induced ER stress, as supported by the induction of three homologs of ER stress marker genes by the drug. Together, these results suggest that ER stress rapidly triggers TAG accumulation in two green microalgae, C. reinhardtii and C. vulgaris. A further investigation of the link between ER stress and TAG synthesis may yield an efficient means of producing biofuel from algae.

  20. Studies of selenium and xenon in inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Bricker, T.

    1994-01-01

    Since its development, inductively coupled plasma mass spectrometry (ICP-MS) has been a widely used analytical technique. ICP-MS offers low detection limits, easy determination of isotope ratios, and simple mass spectra from analyte elements. ICP-MS has been successfully employed for many applications including geological, environmental, biological, metallurgical, food, medical, and industrial. One specific application important to many areas of study involves elemental speciation by using ICP-MS as an element specific detector interfaced to liquid chromatography. Elemental speciation information is important and cannot be obtained by atomic spectrometric methods alone which measure only the total concentration of the element present. Part 1 of this study describes the speciation of selenium in human serum by size exclusion chromatography (SEC) and detection by ICP-MS. Although ICP-MS has been widely sued, room for improvement still exists. Difficulties in ICP-MS include noise in the background, matrix effects, clogging of the sampling orifice with deposited solids, and spectral interference caused by polyatomic ions. Previous work has shown that the addition of xenon into the central channel of the ICP decreases polyatomic ion levels. In Part 2 of this work, a fundamental study involving the measurement of the excitation temperature is carried out to further understand xenon's role in the reduction of polyatomic ions. 155 refs

  1. Mechanisms of neuroimmune gene induction in alcoholism.

    Science.gov (United States)

    Crews, Fulton T; Vetreno, Ryan P

    2016-05-01

    Alcoholism is a primary, chronic relapsing disease of brain reward, motivation, memory, and related circuitry. It is characterized by an individual's continued drinking despite negative consequences related to alcohol use, which is exemplified by alcohol use leading to clinically significant impairment or distress. Chronic alcohol consumption increases the expression of innate immune signaling molecules (ISMs) in the brain that alter cognitive processes and promote alcohol drinking. Unraveling the mechanisms of alcohol-induced neuroimmune gene induction is complicated by positive loops of multiple cytokines and other signaling molecules that converge on nuclear factor kappa-light-chain-enhancer of activated B cells and activator protein-1 leading to induction of additional neuroimmune signaling molecules that amplify and expand the expression of ISMs. Studies from our laboratory employing reverse transcription polymerase chain reaction (RT-PCR) to assess mRNA, immunohistochemistry and Western blot analysis to assess protein expression, and others suggest that ethanol increases brain neuroimmune gene and protein expression through two distinct mechanisms involving (1) systemic induction of innate immune molecules that are transported from blood to the brain and (2) the direct release of high-mobility group box 1 (HMGB1) from neurons in the brain. Released HMGB1 signals through multiple receptors, particularly Toll-like receptor (TLR) 4, that potentiate cytokine receptor responses leading to a hyperexcitable state that disrupts neuronal networks and increases excitotoxic neuronal death. Innate immune gene activation in brain is persistent, consistent with the chronic relapsing disease that is alcoholism. Expression of HMGB1, TLRs, and other ISMs is increased several-fold in the human orbital frontal cortex, and expression of these molecules is highly correlated with each other as well as lifetime alcohol consumption and age of drinking onset. The persistent and

  2. Antibody induction therapy for lung transplant recipients

    DEFF Research Database (Denmark)

    Penninga, Luit; Møller, Christian H; Penninga, Ida Elisabeth Irene

    2013-01-01

    Lung transplantation has become a valuable and well-accepted treatment option for most end-stage lung diseases. Lung transplant recipients are at risk of transplanted organ rejection, and life-long immunosuppression is necessary. Clear evidence is essential to identify an optimal, safe and effect...... and effective immunosuppressive treatment strategy for lung transplant recipients. Consensus has not yet been achieved concerning use of immunosuppressive antibodies against T-cells for induction following lung transplantation....

  3. Linear induction accelerator for heavy ions

    International Nuclear Information System (INIS)

    Keefe, D.

    1976-01-01

    There is considerable recent interest in the use of high energy heavy ions to irradiate deuterium-tritium pellets in a reactor vessel to constitute a power source at the level of 1 GW or more. Various accelerator configurations involving storage rings have been suggested. This paper discusses how the technology of linear induction accelerators - well known to be matched to high current and short pulse length - may offer significant advantages for this application. (author)

  4. Tumor induction by small doses ionising radiation

    International Nuclear Information System (INIS)

    Putten, L.M. van

    1981-01-01

    Tumour induction by low radiation doses is in general a non-linear process. However, two exceptions are well known: myeloid leukemia in Rf mice and mamma tumours in Sprague-Dawley rats. The hypothesis that radiation is highly oncogenic in combination with cell growth stimuli, as reaction to massive cell death after damage of nuclear DNA, is applied to man and the consequences are discussed. (Auth.)

  5. Conformal mapping calculation of railgun skin inductance

    International Nuclear Information System (INIS)

    Huerta, M.A.; Nearing, J.C.

    1991-01-01

    This paper considers the common rail arrangement consisting of two long, parallel, rectangular rails. The authors calculate the inductance per unit length L' in the short flight time limit where the skin depth is much smaller than any rail dimensions, the current is all on the rail surface, and the magnetic field does not penetrate the rails. The authors give the solution based on the Schwartz-Christoffel transformation that maps the boundaries of the problem into a simpler shape

  6. Beam dynamics in heavy ion induction LINACS

    International Nuclear Information System (INIS)

    Smith, L.

    1981-10-01

    Interest in the use of an induction linac to accelerate heavy ions for the purpose of providing the energy required to initiate an inertially confined fusion reaction has stimulated a theoretical effort to investigate various beam dynamical effects associated with high intensity heavy ion beams. This paper presents a summary of the work that has been done so far; transverse, longitudinal and coupled longitudinal transverse effects are discussed

  7. Inductance, electrically adjusted by semiconductor structure

    Directory of Open Access Journals (Sweden)

    Semenov А. А.

    2012-08-01

    Full Text Available A theoretical model of a passive flat inductor with electronic control is offered. Design charts of tank inductance and Q factor dependence on the forward bias voltage of n—i—p—i—n-structure, used as a specific core, the characteristics of which are regulated under the influence of an applied electric field, are presented. The comparison of design values with experimental features has shown their good correspondence with each other.

  8. Mutation induction in plants by ionizing radiation

    International Nuclear Information System (INIS)

    1985-01-01

    This training film deals with the use of x-rays, gamma rays and fast neutrons for mutation induction in plants. Specific features of different types of ionizing radiation and of biological materials are outlined and methods demonstrated which control modifying factors and warrant an efficient physical mutagenesis. The first step of mutation breeding aims at an enhanced level of genetic variation which forms the basis for mutant selection and use in plant breeding

  9. Induction melting of simulated transuranic waste

    International Nuclear Information System (INIS)

    Tenaglia, R.D.; McCall, J.L.

    1983-06-01

    Coreless induction melting was investigated as a method to melt and consolidate waste material representative of the transuranic waste (TRU) stored at the Idaho National Engineering Laboratory (INEL). Waste material was introduced onto the surface of a molten cast iron bath in a coreless induction furnace. Waste metallics were incorporated into the bath. Noncombustibles formed a slag which was poured or skimmed from the bath surface. Stack sampling was performed to characterize the off-gas and particulate matter evolved. Experimental melting tests were performed for a variety of types of wastes including metallics, chemical sludge, soil, concrete, and glass. Each test also included a representative level of combustible materials consisting of paper, wood, cloth, polyvinyl chloride and polyethylene. Metallic wastes were readily processed by induction melting with a minimum of slag production. Test waste consisting primarily of chemical sludge provided fluid slags which could be poured from the bath surface. Processing of wastes consisting of soil, concrete, or glass was limited by the inability to achieve fluid slags. It appears from test results that coreless induction melting is a feasible method to process INEL-type waste materials if two problems can be resolved. First, slag fluidity must be improved to facilitate the collection of slags formed from soil, concrete, or glass containing wastes. Secondly, refractory life must be further optimized to permit prolonged processing of the waste materials. The use of a chrome-bearing high-alumina refractory was found to resist slag line attach much better than a magnesia refractory, although some attack was still noted

  10. NDT of railway components using induction thermography

    Science.gov (United States)

    Netzelmann, U.; Walle, G.; Ehlen, A.; Lugin, S.; Finckbohner, M.; Bessert, S.

    2016-02-01

    Induction or eddy current thermography is used to detect surface cracks in ferritic steel. The technique is applied to detect surface cracks in rails from a moving test car. Cracks were detected at a train speed between 2 and 15 km/h. An automated demonstrator system for testing railway wheels after production is described. While the wheel is rotated, a robot guides the detection unit consisting of inductor and infrared camera over the surface.

  11. Induction linear accelerator technology for SDIO applications

    International Nuclear Information System (INIS)

    Birx, D.; Reginato, L.; Rogers, D.; Trimble, D.

    1986-11-01

    The research effort reported concentrated primarily on three major activities. The first was aimed at improvements in the accelerator drive system of an induction linac to meet the high repetition rate requirements of SDI applications. The second activity centered on a redesign of the accelerator cells to eliminate the beam breakup instabilities, resulting in optimized beam transport. The third activity sought to improve the source of electrons to achieve a higher quality beam to satisfy the requirement of the free electron laser

  12. Vacuum induction melting of uranium ingots

    International Nuclear Information System (INIS)

    Hussain, M.M.; Bagchi, S.N.; Singh, S.P.

    1992-01-01

    Massive uranium ingot is produced from green salt (UF 4 ) using calciothermic reduction (CTR) or magnesiothermic reduction (MTR) process. CTR process has been replaced by MTR process at Trombay due to economic considerations. This paper highlights problems associated with the vacuum induction melting of MTR ingots and the remedial measures taken to produce good quality billets. Details of metallographic examination of inclusions in ingots and billets have been incorporated. (author). 3 figs

  13. Cybernetic systems based on inductive logic

    International Nuclear Information System (INIS)

    Fry, Robert L.

    2001-01-01

    Recent work in the area of inductive logic suggests that cybernetics might be quantified and reduced to engineering practice. If so, then there are considerable implications for engineering, science, and other fields. This paper attempts to capture the essential ideas of cybernetics cast in the light of inductive logic. The described inductive logic extends conventional logic by adding a conjugate logical domain of questions to the logical domain of assertions intrinsic to Boolean Algebra with which most are familiar. This was first posited and developed by Richard Cox. Interestingly enough, these two logical domains, one of questions and the other of assertions, only exist relative to one another with each possessing natural measures of entropy and probability, respectively. Examples are given that highlight the utility of cybernetic approaches to neuroscience, algorithm design, system engineering, and the design and understanding of defensive and offensive systems. For example, the application of cybernetic approaches to defense systems suggests that these systems possess a wavefunction which like quantum mechanics, collapses when we 'look' through the eyes of the system sensors such as radars and optical sensors

  14. Kinetic Inductance Parametric Up-Converter

    Science.gov (United States)

    Kher, A.; Day, P. K.; Eom, B. H.; Zmuidzinas, J.; Leduc, H. G.

    2016-07-01

    We describe a novel class of devices based on the nonlinearity of the kinetic inductance of a superconducting thin film. By placing a current-dependent inductance in a microwave resonator, small currents can be measured through their effect on the resonator's frequency. By using a high-resistivity material for the film and nanowires as kinetic inductors, we can achieve a large coefficient of nonlinearity to improve device sensitivity. We demonstrate a current sensitivity of 8{ {pA/}}√{{ {Hz}}}, making this device useful for transition-edge sensor (TES) readout and other cutting-edge applications. An advantage of these devices is their natural ability to be multiplexed in the frequency domain, enabling large detector arrays for TES-based instruments. A traveling-wave version of the device, consisting of a thin-film microwave transmission line, is also sensitive to small currents as they change the phase length of the line due to their effect on its inductance. We demonstrate a current sensitivity of 5{ {pA/}}√{{ {Hz}}} for this version of the device, making it also suitable for TES readout as well as other current-detection applications. It has the advantage of multi-GHz bandwidth and greater dynamic range, offering a different approach to the resonator version of the device.

  15. Induction of thyroid carcinoma by ionizing radiation

    International Nuclear Information System (INIS)

    Roedler, H.D.

    1987-01-01

    The risk of thyroid carcinoma induction, due to external or internal exposure of the thyroid, is described and quantified. A modified absolute risk model is used. The assessment is based on a risk coefficient of 2.5 induced cases per million persons per cGy per year of risk, derived from US-investigations in persons who had received external radiation therapy during childhood for treatment of benign diseases. This value is considered to be suitable for a dose range of 0.06-15 Gy. Modifying factors are given for age at exposure, gender and relative effectiveness of various radiation sources. The minimum induction period is taken to be 5 years; the remaining life expectancy minus minimum induction period is considered as the number of years at risk. For external exposure of the general public, a calculated incidence for lethal thyroid carcinoma of 7.5 cases per million persons per cGy thyroid dose for the total life time may be derived from the average life expectancy, the age distribution of the population and a mortality of radiation induced thyroid carcinoma of 10%. This figure is in good agreement with earlier estimates. (orig./ECB) [de

  16. NLC Hybrid Solid State Induction Modulator

    CERN Document Server

    Cassel, R L; Pappas, G C; Delamare, J E

    2004-01-01

    The Next Linear Collider accelerator proposal at SLAC requires a high efficiency, highly reliable, and low cost pulsed power modulator to drive the X-band klystrons. The original NLC envisions a solid state induction modulator design to drive up to 8 klystrons to 500 kV for 3 μs at 120 PPS with one modulator delivering greater than 1,000 MW pulse, at 500 kW average. A change in RF compression techniques resulted in only two klystrons needed pulsing per modulator at a reduced pulse width of 1.6 μsec or approximately 250 MW of the pulsed power and 80 kW of average powers. A prototype Design for Manufacturability (DFM) 8-pack modulator was under construction at the time of the change, so a redirection of modulator design was in order. To utilities the equipment which had already be fabricated, a hybrid modulator was designed and constructed using the DFM induction modulator parts and a conventional pulse transformer. The construction and performance of this hybrid two klystron Induction modul...

  17. Induction of protein X in Escherichia coli

    International Nuclear Information System (INIS)

    Little, J.W.; Hanawalt, P.C.

    1977-01-01

    The authors have examined some of the treatments that might induce protein X and they have, in particular, tested the hypothesis that DNA degradation products play an essential role in the induction process. UV irradiation, nalidixic acid treatment, or thymine starvation result in protein X synthesis in wild type strains. However, UV irradiation, unlike nalidixic acid, also induced protein X in recB strains, in which little DNA degradation occurs. The presence of DNA fragments resulting from hostcontrolled restriction of phage lambda DNA did not affect protein X synthesis. It was concluded that no causal relationship exists bewteen the production of DNA fragments and induction of protein X. The presence of the plasmid R 46, which confers enhanced mutagenesis and UV resistance on its host, did not affect protein X synthesis. Growth in the presence of 5-bromouracil, which does not result in production of degradation fragments, resulted eventually in a low rate of protein X synthesis. In dnaA mutants, deficient in the initiation of new rounds of replication, UV irradiation induced protein X, again unlike nalidixic acid. Thus, the inhibition of active replication forks is not an essential requirement for protein X induction. (orig./MG) [de

  18. Induction of homologous recombination in Saccharomyces cerevisiae.

    Science.gov (United States)

    Simon, J R; Moore, P D

    1988-09-01

    We have investigated the effects of UV irradiation of Saccharomyces cerevisiae in order to distinguish whether UV-induced recombination results from the induction of enzymes required for homologous recombination, or the production of substrate sites for recombination containing regions of DNA damage. We utilized split-dose experiments to investigate the induction of proteins required for survival, gene conversion, and mutation in a diploid strain of S. cerevisiae. We demonstrate that inducing doses of UV irradiation followed by a 6 h period of incubation render the cells resistant to challenge doses of UV irradiation. The effects of inducing and challenge doses of UV irradiation upon interchromosomal gene conversion and mutation are strictly additive. Using the yeast URA3 gene cloned in non-replicating single- and double-stranded plasmid vectors that integrate into chromosomal genes upon transformation, we show that UV irradiation of haploid yeast cells and homologous plasmid DNA sequences each stimulate homologous recombination approximately two-fold, and that these effects are additive. Non-specific DNA damage has little effect on the stimulation of homologous recombination, as shown by studies in which UV-irradiated heterologous DNA was included in transformation/recombination experiments. We further demonstrate that the effect of competing single- and double-stranded heterologous DNA sequences differs in UV-irradiated and unirradiated cells, suggesting an induction of recombinational machinery in UV-irradiated S. cerevisiae cells.

  19. EVALUATION OF INDUCTANCE WITH ELECTRICAL WIRES

    Directory of Open Access Journals (Sweden)

    V. Kudry

    2016-08-01

    Full Text Available In this paper proved the possibility of developing passive electronic inductive elements based replace metal wire that is wound inductor, the wire is made of electret. The relative permeability of the electret S  10 000, several orders of magnitude greater than the permeability of conventional insulation materials, i < 10, resulting current in the wire acquires properties bias current. The essence of innovation is to replace the source of of magnetic induction flow that pervades the core of the coil. According to the theory of electrodynamics, current bias, in contrast to conduction current, generated no movement of charge along the wire, but the change of the charge in the local volume.Equivalence bias current and conduction current is manifested in the possibility of forming a magnetic field. The flow through magnetic induction coil core regardless of the current it generates, creates voltage at its ends.The paper also shows the numeric characteristics that determine the effective frequency range, specified the reason why electric a wire with і < 10 can not generate magnetic flux through the core and serve as a passive reactive component.

  20. Induction surface hardening of hard coated steels

    Energy Technology Data Exchange (ETDEWEB)

    Pantleon, K.; Kessler, O.; Hoffann, F.; Mayr, P. [Stiftung Inst. fuer Werkstofftechnik, Bremen (Germany)

    1999-11-01

    The properties of hard coatings deposited using CVD processes are usually excellent. However, high deposition temperatures negatively influence the substrate properties, especially in the case of low alloyed steels. Therefore, a subsequent heat treatment is necessary to restore the properties of steel substrates. Here, induction surface hardening is used as a method of heat treatment after the deposition of TiN hard coatings on AISI 4140 (DIN42CrMo4) substrates. The influences of the heat treatment on both the coating and the substrate properties are discussed in relation to the parameters of induction heating. Thereby, the heating time, heating atmosphere and the power input into the coating-substrate compounds are varied. As a result of induction surface hardening, the properties of the substrates are improved without losing good coating properties. High hardness values in the substrate near the interface allow the AISI 4140 substrates to support TiN hard coatings very well. Consequently, higher critical loads are measured in scratch tests after the heat treatment. Also, compressive residual stresses in the substrate are generated. In addition, only a very low distortion appears. (orig.)

  1. Scalable conditional induction variables (CIV) analysis

    KAUST Repository

    Oancea, Cosmin E.

    2015-02-01

    Subscripts using induction variables that cannot be expressed as a formula in terms of the enclosing-loop indices appear in the low-level implementation of common programming abstractions such as Alter, or stack operations and pose significant challenges to automatic parallelization. Because the complexity of such induction variables is often due to their conditional evaluation across the iteration space of loops we name them Conditional Induction Variables (CIV). This paper presents a flow-sensitive technique that summarizes both such CIV-based and affine subscripts to program level, using the same representation. Our technique requires no modifications of our dependence tests, which is agnostic to the original shape of the subscripts, and is more powerful than previously reported dependence tests that rely on the pairwise disambiguation of read-write references. We have implemented the CIV analysis in our parallelizing compiler and evaluated its impact on five Fortran benchmarks. We have found that that there are many important loops using CIV subscripts and that our analysis can lead to their scalable parallelization. This in turn has led to the parallelization of the benchmark programs they appear in.

  2. Mechanism of fever induction in rabbits.

    Science.gov (United States)

    Siegert, R; Philipp-Dormston, W K; Radsak, K; Menzel, H

    1976-01-01

    Three exogenous pyrogens (Escherichia coli lipopolysaccharide, synthetic double-stranded ribonucleic acid. Newcastle disease virus) were compared with respect to their mechanisms of fever induction in rabbits. All inducers stimulated the production of an endogenous pyrogen demonstrated in the blood as well as prostaglandins of the E group, and of cyclic adenosine 3',5'-monophosphate in the cerebrospinal fluid. The concentrations of these compounds were elevated approximately twofold as compared to the controls. Independently of the mode of induction, the fever reaction could be prevented by pretreatment with 5 mg of cycloheximide per kg, although the three fever mediators were induced as in febrile animals. Consequently, at least one additional fever mediator that is sensitive to a 30 to 50% inhibition of protein synthesis by cycloheximide has to be postulated. The comparable reactions of the rabbits after administration of different pyrogens argues for a similar fever mechanism. In contrast to fever induction there was no stimulation of endogenous pyrogen, prostaglandins of the E group, and cyclic adenosine 3',5'-monophosphate in hyperthermia as a consequence of exposure of the animals to exogenous overheating. Furthermore, hyperthermia could not be prevented by cycloheximide. PMID:185148

  3. First report of phytochelatins in a mushroom: induction of phytochelatins by metal exposure in Boletus edulis.

    Science.gov (United States)

    Collin-Hansen, Christian; Pedersen, Sindre A; Andersen, Rolf A; Steinnes, Eiliv

    2007-01-01

    Some species of macromycetes (mushrooms) consistently are found to contain high concentrations of toxic metals such as cadmium (Cd) and mercury (Hg), and consumption of wild-growing mushrooms is acknowledged as a significant source for Cd and Hg in humans. Yet little is known about the speciation of Cd and Hg in mushroom tissues. Here we present the first evidence of peptides of the phytochelatin family being responsible for binding a large fraction of Cd in caps of the macromycete Boletus edulis exposed to excess metals. Concentrations of Cd, Zn, Cu and Hg, as well as cytosolic Cd-binding capacity (CCBC), glutathione (GSH) and free proline (Pro) were quantified in fruiting bodies of B. edulis differentially exposed to a wide range of metals. Metal distribution among cytosolic compounds were investigated by size exclusion chromatography (SEC), followed by metal determinations with atomic absorption chromatography (AAS) and HR-ICP-MS. Cd-binding compounds in SEC elutates were investigated further by high performance liquid chromatography-mass spectrometry (HPLC-MS). CCBC was >90 times higher in the exposed group relative to the reference group (Mann-Whitney's P < 0.001), whereas concentrations of free Pro were almost identical for the two groups. For the whole study selection, CCBC correlated positively with metal exposure (Spearman's P < 0.001 for all four metals), suggesting dose-dependent induction of Cd-binding compounds by exposure to these metals, possibly as a defense mechanism. The presence of phytochelatins (PCs), a family of cystein-rich oligopeptides, was confirmed in Cd-containing SEC fractions by HPLC-MS. The appearance of more complex PCs was coupled to declining concentrations of GSH. To our knowledge this is the first report demonstrating the presence of PCs in a macromycete.

  4. Effect of Inductive Coil Shape on Sensing Performance of Linear Displacement Sensor Using Thin Inductive Coil and Pattern Guide

    Directory of Open Access Journals (Sweden)

    Hiroyuki Wakiwaka

    2011-11-01

    Full Text Available This paper discusses the effect of inductive coil shape on the sensing performance of a linear displacement sensor. The linear displacement sensor consists of a thin type inductive coil with a thin pattern guide, thus being suitable for tiny space applications. The position can be detected by measuring the inductance of the inductive coil. At each position due to the change in inductive coil area facing the pattern guide the value of inductance is different. Therefore, the objective of this research is to study various inductive coil pattern shapes and to propose the pattern that can achieve good sensing performance. Various shapes of meander, triangular type meander, square and circle shape with different turn number of inductive coils are examined in this study. The inductance is measured with the sensor sensitivity and linearity as a performance evaluation parameter of the sensor. In conclusion, each inductive coil shape has its own advantages and disadvantages. For instance, the circle shape inductive coil produces high sensitivity with a low linearity response. Meanwhile, the square shape inductive coil has a medium sensitivity with higher linearity.

  5. Radial Chromatography for the Separation of Nitroaniline Isomers

    Science.gov (United States)

    Miller, Robert B.; Case, William S.

    2011-01-01

    Separation techniques are usually presented in the undergraduate organic laboratory to teach students how to purify and isolate compounds. Often the concept of liquid chromatography is introduced by having students create "silica gel columns" to separate components of a reaction mixture. Although useful, column chromatography can be a laborious…

  6. Using Ion Exchange Chromatography to Separate and Quantify Complex Ions

    Science.gov (United States)

    Johnson, Brian J.

    2014-01-01

    Ion exchange chromatography is an important technique in the separation of charged species, particularly in biological, inorganic, and environmental samples. In this experiment, students are supplied with a mixture of two substitution-inert complex ions. They separate the complexes by ion exchange chromatography using a "flash"…

  7. Pseudo-affinity chromatography of rumen microbial cellulase on ...

    African Journals Online (AJOL)

    Pseudo-affinity chromatography of rumen microbial cellulase on Sepharose- Cibacron Blue F3GA. ... African Journal of Biotechnology ... Pseudo affinity adsorption of bioproducts on Sepharose-cibacron blue F3-GA was subjected to rumen microbial enzyme evaluation through batch binding and column chromatography of ...

  8. Gel chromatography of sup(99m)Tc-labelled compounds

    International Nuclear Information System (INIS)

    Vilcek, S.; Machan, V.; Kalincak, M.

    1976-01-01

    The present state of gel chromatography of sup(99m)Tc-labelled compounds is reviewed. Examples are given of gel chromatography for preparing labelled compounds and for quality control analysis and the development of new types of sup(99m)Tc-labelled compounds. The factors which influence the gel chromatography of these compounds are discussed, i.e., the nature of the elution agent, the duration of the contact of the gel and the preparation the gel type, the nature of the labelled compound. The GCS method (gel chromatography scanning) is briefly described. The advantages of gel chromatography as compared with other chromatographic techniques for sup(99m)Tc-labelled compounds are summarized. (author)

  9. Counter-current motion in counter-current chromatography.

    Science.gov (United States)

    Ito, Yoichiro

    2014-12-12

    After the CCC2012 meeting, I have received an e-mail regarding the terminology of "Countercurrent Chromatography". It stated that the term "Countercurrent" is a misnomer, because its stationary phase is motionless in the column and that the method should be renamed as liquid-liquid separations or centrifugal separations. However, it was found that these names are already used for various other techniques as found via Google search. The term "Countercurrent Chromatography" was originally made after two preparative methods of Countercurrent distribution and liquid Chromatography, both having no countercurrent motion in the column. However, it is surprising to find that this F1 hybrid method "Countercurrent Chromatography" can clearly exhibit countercurrent motion within the separation column in both hydrodynamic and hydrostatic equilibrium systems. This justifies that "Countercurrent Chromatography" is a proper term for this chromatographic method. Published by Elsevier B.V.

  10. In vivo induction of phase II detoxifying enzymes, glutathione transferase and quinone reductase by citrus triterpenoids

    Directory of Open Access Journals (Sweden)

    Ahmad Hassan

    2010-09-01

    Full Text Available Abstract Background Several cell culture and animal studies demonstrated that citrus bioactive compounds have protective effects against certain types of cancer. Among several classes of citrus bioactive compounds, limonoids were reported to prevent different types of cancer. Furthermore, the structures of citrus limonoids were reported to influence the activity of phase II detoxifying enzymes. The purpose of the study was to evaluate how variations in the structures of citrus limonoids (namely nomilin, deacetyl nomilin, and isoobacunoic acid and a mixture of limonoids would influence phase II enzyme activity in excised tissues from a mouse model. Methods In the current study, defatted sour orange seed powder was extracted with ethyl acetate and subjected to silica gel chromatography. The HPLC, NMR and mass spectra were used to elucidate the purity and structure of compounds. Female A/J mice were treated with three limonoids and a mixture in order to evaluate their effect on phase II enzymes in four different tissues. Assays for glutathione S-transferase and NAD(PH: quinone reductase (QR were used to evaluate induction of phase II enzymatic activity. Results The highest induction of GST against 1-chloro-2,4-dinitrobenzene (CDNB was observed in stomach (whole, 58% by nomilin, followed by 25% isoobacunoic acid and 19% deacetyl nomilin. Deacetyl nomilin in intestine (small as well as liver significantly reduced GST activity against CDNB. Additionally isoobacunoic acid and the limonoid mixture in liver demonstrated a significant reduction of GST activity against CDNB. Nomilin significantly induced GST activity against 4-nitroquinoline 1-oxide (4NQO, intestine (280% and stomach (75% while deacetyl nomilin showed significant induction only in intestine (73%. Induction of GST activity was also observed in intestine (93% and stomach (45% treated with the limonoid mixture. Finally, a significant induction of NAD(PH: quinone reductase (QR activity was

  11. Phytochemical analysis of ethanolic extract of Dichrostachys Cinerea W and Arn leaves by a thin layer chromatography, high performance thin layer chromatography and column chromatography

    OpenAIRE

    M Vijayalakshmi; K Periyanayagam; K Kavitha; K Akilandeshwari

    2013-01-01

    Background: The leaves of Dichrostachys cinerea are used as laxative, diuretic, painkiller. It is also used in the treatment of gonorrhoea, boils, oedema, gout, veneral diseases and nasopharyngeal affections, etc. Materials and Methods: The Phytochemical investigation of ethanolic extract of D. cinerea leaves were performed by standard chemical tests, thin layer chromatography (TLC) by using various solvent systems, and by high performance liquid chromatography (HPTLC). Two compounds were...

  12. Induction Heating Process Design Using COMSOL Multiphysics Software

    Directory of Open Access Journals (Sweden)

    Andy Triwinarko

    2011-08-01

    Full Text Available Induction heating is clean environmental heating process due to a non-contact heating process. There is lots of the induction heating type that be used in the home appliance but it is still new technology in Indonesia. The main interesting area of the induction heating design is the efficiency of the usage of energy and choice of the plate material. COMSOL Multiphysics Software can be used to simulate and estimate the induction heating process. Therefore, the software can be used to design the induction heating process that will have a optimum efficiency. The properties of the induction heating design were also simulated and analyzed such as effect of inductors width, inductors distance, and conductive plate material. The result was shown that the good design of induction heating must have a short width and distance inductor and used silicon carbide as material plate with high frequency controller.

  13. CFOA-Based Lossless and Lossy Inductance Simulators

    Directory of Open Access Journals (Sweden)

    F. Kaçar

    2011-09-01

    Full Text Available Inductance simulator is a useful component in the circuit synthesis theory especially for analog signal processing applications such as filter, chaotic oscillator design, analog phase shifters and cancellation of parasitic element. In this study, new four inductance simulator topologies employing a single current feedback operational amplifier are presented. The presented topologies require few passive components. The first topology is intended for negative inductance simulation, the second topology is for lossy series inductance, the third one is for lossy parallel inductance and the fourth topology is for negative parallel (-R (-L (-C simulation. The performance of the proposed CFOA based inductance simulators is demonstrated on both a second-order low-pass filter and inductance cancellation circuit. PSPICE simulations are given to verify the theoretical analysis.

  14. Simultaneous analysis for water- and fat-soluble vitamins by a novel single chromatography technique unifying supercritical fluid chromatography and liquid chromatography.

    Science.gov (United States)

    Taguchi, Kaori; Fukusaki, Eiichiro; Bamba, Takeshi

    2014-10-03

    Chromatography techniques usually use a single state in the mobile phase, such as liquid, gas, or supercritical fluid. Chromatographers manage one of these techniques for their purpose but are sometimes required to use multiple methods, or even worse, multiple techniques when the target compounds have a wide range of chemical properties. To overcome this challenge, we developed a single method covering a diverse compound range by means of a "unified" chromatography which completely bridges supercritical fluid chromatography and liquid chromatography. In our method, the phase state was continuously changed in the following order; supercritical, subcritical and liquid. Moreover, the gradient of the mobile phase starting at almost 100% CO2 was replaced with 100% methanol at the end completely. As a result, this approach achieved further extension of the polarity range of the mobile phase in a single run, and successfully enabled the simultaneous analysis of fat- and water-soluble vitamins with a wide logP range of -2.11 to 10.12. Furthermore, the 17 vitamins were exceptionally separated in 4min. Our results indicated that the use of dense CO2 and the replacement of CO2 by methanol are practical approaches in unified chromatography covering diverse compounds. Additionally, this is a first report to apply the novel approach to unified chromatography, and can open another door for diverse compound analysis in a single chromatographic technique with single injection, single column and single system. Copyright © 2014. Published by Elsevier B.V.

  15. Peak broadening in paper chromatography and related techniques : III. Peak broadening in thin-layer chromatography on cellulose powder

    NARCIS (Netherlands)

    Ligny, C.L. de; Remijnse, A.G.

    1968-01-01

    The mechanism of peak broadening in thin-layer chromatography on cellulose powder was investigated by comparing the peak widths obtained in chromatography with those caused only by diffusion in the cellulose powder, for a set of amino acids of widely differing RF values and six kinds of cellulose

  16. XII All-Russian conference on gas chromatography. Program. Summary of reports

    International Nuclear Information System (INIS)

    2002-01-01

    Program and summary of reports of the XII All-Russian conference on gas chromatography are performed. The conference took place in Samara, 10-14 June, 2002. Reports on physicochemical regularities of gas chromatography, application of chromatographic methods in atomic energetics are included in the program of the conference. Part of the reports are deleted to the analytical application of the gas chromatography. Adsorbents for the gas chromatography, complex methods, mathematic methods in chromatography, ecological aspects of the gas chromatography [ru

  17. Relationship between the induction frequency and LTE in inductively coupled plasmas

    International Nuclear Information System (INIS)

    Mostaghimi, J.; Boulos, M.I.

    1990-01-01

    In this paper, the effect of the induction frequency on the local thermodynamic equilibrium (LTE) conditions in an inductively coupled plasma is investigated. Using generators with frequencies ranging from 5 to 56 MHz, a previous study investigated demonstrated the importance of this effect. Their measurements of the excitation temperatures of the iron atomic lines showed a sharp decrease in this temperature as a result of the increase in frequency. Another conclusion was that, all other parameters constant, increase in frequency will help the promotion of non-LTE effects

  18. Effective Induction Heating around Strongly Magnetized Stars

    Science.gov (United States)

    Kislyakova, K. G.; Fossati, L.; Johnstone, C. P.; Noack, L.; Lüftinger, T.; Zaitsev, V. V.; Lammer, H.

    2018-05-01

    Planets that are embedded in the changing magnetic fields of their host stars can experience significant induction heating in their interiors caused by the planet’s orbital motion. For induction heating to be substantial, the planetary orbit has to be inclined with respect to the stellar rotation and dipole axes. Using WX UMa, for which the rotation and magnetic axes are aligned, as an example, we show that for close-in planets on inclined orbits, induction heating can be stronger than the tidal heating occurring inside Jupiter’s satellite Io; namely, it can generate a surface heat flux exceeding 2 W m‑2. An internal heating source of such magnitude can lead to extreme volcanic activity on the planet’s surface, possibly also to internal local magma oceans, and to the formation of a plasma torus around the star aligned with the planetary orbit. A strongly volcanically active planet would eject into space mostly SO2, which would then dissociate into oxygen and sulphur atoms. Young planets would also eject CO2. Oxygen would therefore be the major component of the torus. If the O I column density of the torus exceeds ≈1012 cm‑2, the torus could be revealed by detecting absorption signatures at the position of the strong far-ultraviolet O I triplet at about 1304 Å. We estimate that this condition is satisfied if the O I atoms in the torus escape the system at a velocity smaller than 1–10 km s‑1. These estimates are valid also for a tidally heated planet.

  19. Factors influencing induction of adaptive response

    International Nuclear Information System (INIS)

    Misonoh, Jun; Ojima, Mitsuaki; Yonezawa, Morio

    2000-01-01

    Exposure to low doses of X-rays makes ICR mice resistant to subsequent sublethal irradiation and decrease mortality from hematopoietic death. Many factors, however, influence the induction of radioresistance. For instances, in ICR mice, the priming irradiation with 0.50 Gy was effective in the induction of radioresistance, when it is given at 6-week old, 2 weeks prior to subsequent sublethal irradiation. One hundred-fifty kV X-ray filtered off the soft component through 1.0 mm aluminum and 0.2 mm copper induces radioadaptive response as well as the harder radiation such as 260 kV X-ray filtered through 0.5 mm aluminum and 0.3 mm copper. Dose rate of priming irradiation also seemed to influence the induction of radioresistance. Priming irradiation with 0.50 Gy at 0.50 Gy/min and 0.25 Gy/min induced adaptive response, while same 0.50 Gy given at 0.063 Gy/min didn't. To make the matter complicated, when mice were pre-irradiated with 0.50 Gy at 0.013 Gy/min in the irradiation cell which was 1.2 x 1.2 x 1.4 times larger than the usual one, adaptive response was induced again. These results suggested that mice felt more uncomfortable when they were packing in the irradiation cell with little free space even for several minutes than when they were placed in the cell with much free space for about 40 minutes, and such a stress might give the mice some resistance to the subsequent sublethal irradiation. (author)

  20. Non-inductively driven currents in JET

    International Nuclear Information System (INIS)

    Challis, C.D.; Cordey, J.G.; Hamnen, H.; Stubberfield, P.M.; Christiansen, J.P.; Lazzaro, E.; Muir, D.G.; Stork, D.; Thompson, E.

    1989-01-01

    Neutral beam heating data from JET have been analysed in detail to determine what proportion of the current is driven non-inductively. It is found that in low density limiter discharges, currents of the order of 0.5 MA are driven, while in H-mode plasmas currents of the order of 0.7 MA are measured. These measured currents are found to be in reasonable agreement with theoretical predictions based on neoclassical models. In low density plasmas the beam driven current is large while the neoclassical bootstrap current dominates H-mode plasmas. (author). 19 refs, 11 figs

  1. An induction linac injector for scaled experiments

    International Nuclear Information System (INIS)

    Rutkowski, H.L.; Faltens, A.; Pike, C.; Brodzik, D.; Johnson, R.M.; Vanecek, D.; Hewett, D.W.

    1991-04-01

    An injector is being developed at LBL that would serve as the front end of a scaled induction linac accelerator technology experiment for heavy ion fusion. The ion mass being used is in the range 10--18. It is a multi-beam device intended to accelerate up to 2 MeV with 500 mA in each beam. The first half of the accelerating column has been built and experiments with one carbon beam are underway at the 1 MeV level. 5 refs., 1 fig

  2. Current evidence supporting "letrozole" for ovulation induction

    Directory of Open Access Journals (Sweden)

    Sujata Kar

    2013-01-01

    Full Text Available Aromatase inhibitor "letrozole" was first introduced as a potential ovulation induction (OI drug almost a decade back. Large number of studies has been published using letrozole for OI: In polycystic ovary syndrome (PCOS women, clomiphene citrate (CC resistant women, for intrauterine insemination and also in various protocols of mild stimulation for in vitro fertilization/intracytoplasmic sperm injection (IVF/ICSI. Letrozole appears to be a good option, with its oral route of administration, cost, shorter half-life and negligible side effects. However, the verdict on efficacy and safety of letrozole is still uncertain. This review explores the current scientific data supporting letrozole for OI.

  3. Sensorless soft starters for loaded induction motors

    Energy Technology Data Exchange (ETDEWEB)

    Chrisanov, V.I.; Konovalov, Y.N. [Power Plearonics Department, State University of Telecommunication, St. Petersburg (Russian Federation)

    1997-12-31

    The paper is devoted to the research and design of sensorless thyristor soft starters for loaded induction motors (IM) with short circuited squirrel case rotors. It is shown that the applied direct converter topology depends on the output power and consists of a small number of thyristors with special algorithm of switching to realize voltage - frequency control of IM drive systems at low speeds of starting. Sensorless control is realized from the both sides when neither direct converter nor drive system consists of any additional transducers for soft starting operation. (orig.) 4 refs.

  4. Two-phase induction motor drives

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Lungeanu, Florin; Skaug, Kenneth

    2004-01-01

    There is a continuous debate today concerning the ?motor of the future? for low-power applications requiring less than 1-2 kW. The specialists are focusing on superior motors [1] like brushless-dc, permanent-magnet synchronous, or electronically commutated types, because they show improvements...... in efficiency, reliability, torque-per-volume/mass ratio, maintenance, and service life. Despite this effort, the industry seems to be responding with manifest rigidity in changing standard induction motor solutions when considering the installed volume into the field, the investment in manufacturing base...

  5. Superconducting inductive displacement detection of a microcantilever

    Science.gov (United States)

    Vinante, A.

    2014-07-01

    We demonstrate a superconducting inductive technique to measure the displacement of a micromechanical resonator. In our scheme, a type I superconducting microsphere is attached to the free end of a microcantilever and approached to the loop of a dc Superconducting Quantum Interference Device (SQUID) microsusceptometer. A local magnetic field as low as 100 μT, generated by a field coil concentric to the SQUID, enables detection of the cantilever thermomechanical noise at 4.2 K. The magnetomechanical coupling and the magnetic spring are in good agreement with image method calculations assuming pure Meissner effect. These measurements are relevant to recent proposals of quantum magnetomechanics experiments based on levitating superconducting microparticles.

  6. Velocity measurement of conductor using electromagnetic induction

    International Nuclear Information System (INIS)

    Kim, Gu Hwa; Kim, Ho Young; Park, Joon Po; Jeong, Hee Tae; Lee, Eui Wan

    2002-01-01

    A basic technology was investigated to measure the speed of conductor by non-contact electromagnetic method. The principle of the velocity sensor was electromagnetic induction. To design electromagnet for velocity sensor, 2D electromagnetic analysis was performed using FEM software. The sensor output was analyzed according to the parameters of velocity sensor, such as the type of magnetizing currents and the lift-off. Output of magnetic sensor was linearly depended on the conductor speed and magnetizing current. To compensate the lift-off changes during measurement of velocity, the other magnetic sensor was put at the pole of electromagnet.

  7. Linear induction accelerator for heavy ions

    International Nuclear Information System (INIS)

    Keefe, D.

    1976-09-01

    There is considerable recent interest in the use of high energy (γ = 1.1), heavy (A greater than or equal to 100) ions to irradiate deuterium--tritium pellets in a reactor vessel to constitute a power source at the level of 1 GW or more. Various accelerator configurations involving storage rings have been suggested. A discussion is given of how the technology of Linear Induction Accelerators--well known to be matched to high current and short pulse length--may offer significant advantages for this application

  8. Cullet Manufacture Using the Cylindrical Induction Melter

    International Nuclear Information System (INIS)

    Miller, D. H.

    2000-01-01

    The base process for vitrification of the Am/Cm solution stored in F-canyon uses 25SrABS cullet as the glass former. A small portion of the cullet used in the SRTC development work was purchased from Corning while the majority was made in the 5 inch Cylindrical Induction Melter (CIM5). Task 1.01 of TTR-NMSS/SE-006, Additional Am-Cm Process Development Studies, requested that a process for the glass former (cullet) fabrication be specified. This report provides the process details for 25SrAB cullet production thereby satisfying Task 1.01

  9. Inductive voltage compensation in superconducting magnet systems

    International Nuclear Information System (INIS)

    Yeh, H.T.; Goddard, J.S.; Shen, S.S.

    1979-01-01

    This paper details several techniques of inductive voltage compensation developed for quench detection in superconducting magnet systems with multiple coils and power supplies, with particular application for the Large Coil Test Facility (LCTF). Sources of noise, their magnitudes, and the sensitivity required for normal zone detection to avoid damage to the magnets are discussed. Two passive compensation schemes (second difference and central difference) are introduced and illustrated by parameters of LCTF; these take advantage of coil symmetries and other system characteristics. An active compensation scheme based on current rate input fom pickup coils and utilizing theory on ac loss voltage for calibration was tested, and the experimental setup and test results are discussed

  10. Ovulation induction in polycystic ovary syndrome.

    Science.gov (United States)

    Vause, Tannys D R; Cheung, Anthony P

    2010-05-01

    To review current non-pharmacologic and pharmacologic options for ovulation induction in women with polycystic ovary syndrome (PCOS). This guideline reviews the evidence for the various options for ovulation induction in PCOS. Ovulation, pregnancy and live birth rates, risks, and side effects are the outcomes of interest. Published literature was retrieved through searches of Medline using appropriate controlled vocabulary and key words. Results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies. Grey (unpublished) literature was identified through searching the websites of health technology assessment and of health technology assessment-related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical specialty societies. The evidence gathered was reviewed and evaluated by the Reproductive Endocrinology and Infertility Committee of the Society of Obstetricians and Gynaecologists of Canada. The quality of evidence was quantified using the Canadian Task Force on Preventive Health Care. Benefits include weight reduction and improvements in ovulation, pregnancy, and live birth rates. Potential harms include medication side effects and multiple pregnancies. These guidelines have been reviewed and approved by the Reproductive Endocrinology and Infertility Committee of the SOGC. The Society of Obstetricians and Gynaecologists of Canada. RECOMMENDATIONS 1. Weight loss, exercise, and lifestyle modifications have been proven effective in restoring ovulatory cycles and achieving pregnancy in overweight women with PCOS and should be the first-line option for these women. (II-3A) Morbidly obese women should seek expert advice about pregnancy risk. (III-A) 2. Clomiphene citrate has been proven effective in ovulation induction for women with PCOS and should be considered the first-line therapy. Patients should be informed that there is an increased risk

  11. A History of Probabilistic Inductive Logic Programming

    Directory of Open Access Journals (Sweden)

    Fabrizio eRiguzzi

    2014-09-01

    Full Text Available The field of Probabilistic Logic Programming (PLP has seen significant advances in the last 20 years, with many proposals for languages that combine probability with logic programming. Since the start, the problem of learning probabilistic logic programs has been the focus of much attention. Learning these programs represents a whole subfield of Inductive Logic Programming (ILP. In Probabilistic ILP (PILP two problems are considered: learning the parameters of a program given the structure (the rules and learning both the structure and the parameters. Usually structure learning systems use parameter learning as a subroutine. In this article we present an overview of PILP and discuss the main results.

  12. In vitro induction of tuber formation with special reference to ...

    African Journals Online (AJOL)

    login

    2013-05-15

    May 15, 2013 ... performance liquid chromatography (HPLC) and liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS). There was a ... medicinal herb having many therapeutic applications in. Ayurvedic, Unani .... The qualitative analysis was done on the basis of common ion peak available in the ...

  13. Synthetic signal injection using inductive coupling

    Science.gov (United States)

    Marro, Kenneth I.; Lee, Donghoon; Shankland, Eric G.; Mathis, Clinton M.; Hayes, Cecil E.; Amara, Catherine E.; Kushmerick, Martin J.

    2008-09-01

    Conversion of MR signals into units of metabolite concentration requires a very high level of diligence to account for the numerous parameters and transformations that affect the proportionality between the quantity of excited nuclei in the acquisition volume and the integrated area of the corresponding peak in the spectrum. We describe a method that eases this burden with respect to the transformations that occur during and following data acquisition. The conceptual approach is similar to the ERETIC method, which uses a pre-calibrated, artificial reference signal as a calibration factor to accomplish the conversion. The distinguishing feature of our method is that the artificial signal is introduced strictly via induction, rather than radiation. We tested a prototype probe that includes a second RF coil rigidly positioned close to the receive coil so that there was constant mutual inductance between them. The artificial signal was transmitted through the second RF coil and acquired by the receive coil in parallel with the real signal. Our results demonstrate that the calibration factor is immune to changes in sample resistance. This is a key advantage because it removes the cumbersome requirement that coil loading conditions be the same for the calibration sample as for experimental samples. The method should be adaptable to human studies and could allow more practical and accurate quantification of metabolite content.

  14. Energy Efficiency Model for Induction Furnace

    Science.gov (United States)

    Dey, Asit Kr

    2018-01-01

    In this paper, a system of a solar induction furnace unit was design to find out a new solution for the existing AC power consuming heating process through Supervisory control and data acquisition system. This unit can be connected directly to the DC system without any internal conversion inside the device. The performance of the new system solution is compared with the existing one in terms of power consumption and losses. This work also investigated energy save, system improvement, process control model in a foundry induction furnace heating framework corresponding to PV solar power supply. The results are analysed for long run in terms of saving energy and integrated process system. The data acquisition system base solar foundry plant is an extremely multifaceted system that can be run over an almost innumerable range of operating conditions, each characterized by specific energy consumption. Determining ideal operating conditions is a key challenge that requires the involvement of the latest automation technologies, each one contributing to allow not only the acquisition, processing, storage, retrieval and visualization of data, but also the implementation of automatic control strategies that can expand the achievement envelope in terms of melting process, safety and energy efficiency.

  15. Inductive reasoning about causally transmitted properties.

    Science.gov (United States)

    Shafto, Patrick; Kemp, Charles; Bonawitz, Elizabeth Baraff; Coley, John D; Tenenbaum, Joshua B

    2008-11-01

    Different intuitive theories constrain and guide inferences in different contexts. Formalizing simple intuitive theories as probabilistic processes operating over structured representations, we present a new computational model of category-based induction about causally transmitted properties. A first experiment demonstrates undergraduates' context-sensitive use of taxonomic and food web knowledge to guide reasoning about causal transmission and shows good qualitative agreement between model predictions and human inferences. A second experiment demonstrates strong quantitative and qualitative fits to inferences about a more complex artificial food web. A third experiment investigates human reasoning about complex novel food webs where species have known taxonomic relations. Results demonstrate a double-dissociation between the predictions of our causal model and a related taxonomic model [Kemp, C., & Tenenbaum, J. B. (2003). Learning domain structures. In Proceedings of the 25th annual conference of the cognitive science society]: the causal model predicts human inferences about diseases but not genes, while the taxonomic model predicts human inferences about genes but not diseases. We contrast our framework with previous models of category-based induction and previous formal instantiations of intuitive theories, and outline challenges in developing a complete model of context-sensitive reasoning.

  16. Experiments and prospects for induction linac drivers

    International Nuclear Information System (INIS)

    Keefe, D.

    1986-05-01

    In the last three years, the US program in Heavy Ion Fusion has concentrated on understanding the induction linac approach to a power-plant driver. In this method it is important that the beam current be maximized throughout the accelerator. Consequently, it is crucial to understand the space-charge limit in the AG transport system in the linac and, also, to achieve current amplification during acceleration to keep pace with the kinematical increase of this limit with energy. Experimental results on both these matters and also on the use of multiple beams (inside the same accelerating structure) will be described. A new examination of the most attractive properties of the induction linac for a fusion driver has clearly pointed to the advantage of using heavy ions with a charge-state greater than unity - perhaps q = 3 may be an optimum. This development places even greater importance on understanding space-charge limits and mechanisms for emittance growth; also, it will require a new emphasis on the development of a suitable ion source

  17. Time to Reconsider Stem Cell Induction Strategies

    Directory of Open Access Journals (Sweden)

    Hans-Werner Denker

    2012-12-01

    Full Text Available Recent developments in stem cell research suggest that it may be time to reconsider the current focus of stem cell induction strategies. During the previous five years, approximately, the induction of pluripotency in somatic cells, i.e., the generation of so-called ‘induced pluripotent stem cells’ (iPSCs, has become the focus of ongoing research in many stem cell laboratories, because this technology promises to overcome limitations (both technical and ethical seen in the production and use of embryonic stem cells (ESCs. A rapidly increasing number of publications suggest, however, that it is now possible to choose instead other, alternative ways of generating stem and progenitor cells bypassing pluripotency. These new strategies may offer important advantages with respect to ethics, as well as to safety considerations. The present communication discusses why these strategies may provide possibilities for an escape from the dilemma presented by pluripotent stem cells (self-organization potential, cloning by tetraploid complementation, patenting problems and tumor formation risk.

  18. Induction of Mutants in Durum Wheat

    International Nuclear Information System (INIS)

    AL-Ubaidi, M.; Ibrahim, I.; AL-Hadithi, A.

    2002-01-01

    This investigation presents a breeding program for induction and development of a new genotype of durum wheat, resistant to lodging with high yield, by irradiation durum wheat hybrids (F2) with gamma rays 100 Gy, during 1990-1997 cultivation seasons. This program involves: induction of variability, selection evaluation of the mutants at three locations: Twaitha (Baghdad) Latifya ( Babylon) and Swari (Kutt). All mutants showed resistance to lodging and there was a significant reduction in plant height. Mutant SIXIZ-22 surpassed other mutants and its origin in lodging resistance and plant height (83.5,82.8 and 89.4 cm) in the three locations at generation M5 and M6, respectively. Also, there were significant differences between mutant and their origin in the number of spikes/M 2 and grain yild during the two successive generation. On the other hand, mutant IZxCO-105 surpassed other mutants in the number of spikes/M 2 (231.8,242.3 and 292) and grain yield (4336,3376 and 5232 kg/ha) in all testing location, respectively . (authors) 14 refs., 4 tabs

  19. Addiction, adolescence, and innate immune gene induction

    Directory of Open Access Journals (Sweden)

    Fulton T Crews

    2011-04-01

    Full Text Available Repeated drug use/abuse amplifies psychopathology, progressively reducing frontal lobe behavioral control and cognitive flexibility while simultaneously increasing limbic temporal lobe negative emotionality. The period of adolescence is a neurodevelopmental stage characterized by poor behavioral control as well as strong limbic reward and thrill seeking. Repeated drug abuse and/or stress during this stage increase the risk of addiction and elevate activator innate immune signaling in the brain. Nuclear factor-kappa-light-chain-enhancer of activated B cells (NF-κB is a key glial transcription factor that regulates proinflammatory chemokines, cytokines, oxidases, proteases, and other innate immune genes. Induction of innate brain immune gene expression (e.g., NF-κB facilitates negative affect, depression-like behaviors, and inhibits hippocampal neurogenesis. In addition, innate immune gene induction alters cortical neurotransmission consistent with loss of behavioral control. Studies with anti-oxidant, anti-inflammatory, and anti-depressant drugs as well as opiate antagonists link persistent innate immune gene expression to key behavioral components of addiction, e.g. negative affect-anxiety and loss of frontal cortical behavioral control. This review suggests that persistent and progressive changes in innate immune gene expression contribute to the development of addiction. Innate immune genes may represent a novel new target for addiction therapy.

  20. Radiation induction of cancer of the skin

    International Nuclear Information System (INIS)

    Fry, R.J.M.; Storer, J.B.; Burns, F.J.

    1985-01-01

    The induction of epidermal tumors was studied using exposures to 25 kV x-rays with or without subsequent exposures to 12-0-tetradeconyl phorbol-13 acetate (TPA) or ultraviolet radiation (uvr) 280-400 nm. Fractionation regimens and total exposure up to 4000R produced no squamous cell carcinomas. When these regimes were followed by TPA an incidence of about 80% was obtained, and incidence of 60% when uvr exposures followed the x-irradiation. A dose-dependent increase in fibrosarcomas was found when x-irradiation was followed by 24 weeks of topical treatment with TPA. These results support the contention that uvr can enhance the expression of cells initiated by x-rays. The experimental evidence is compared with the data from the tinea capitis patients treated with x-rays. In C3HF/He male mice exposed to 50, 100, 150 and 200 rads 137 Cs gamma rays the induction rate for fibrosarcomas was 2.9 x 10 -4 per cGy/per mouse. This result compares with 2.5 x 10 -6 transformations per surviving cell per cGy with 10T1/2 cells that are fibroblasts derived from C3H mice. 16 refs., 1 fig., 1 tab