WorldWideScience

Sample records for chromatographic peak capacities

  1. Peak capacity in unidimensional chromatography.

    Science.gov (United States)

    Neue, Uwe Dieter

    2008-03-14

    The currently existing knowledge about peak capacity in unidimensional separations is reviewed. The majority of the paper is dedicated to reversed-phase gradient chromatography, covering specific techniques as well as the subject of peak compression. Other sections deal with peak capacity in isocratic chromatography, size-exclusion chromatography and ion-exchange chromatography. An important topic is the limitation of the separation power and the meaning of the concept of peak capacity for real applications.

  2. Probabilistic peak detection for first-order chromatographic data

    NARCIS (Netherlands)

    Lopatka, M.; Vivó-Truyols, G.; Sjerps, M.J.

    2014-01-01

    We present a novel algorithm for probabilistic peak detection in first-order chromatographic data. Unlike conventional methods that deliver a binary answer pertaining to the expected presence or absence of a chromatographic peak, our method calculates the probability of a point being affected by suc

  3. [A peak recognition algorithm designed for chromatographic peaks of transformer oil].

    Science.gov (United States)

    Ou, Linjun; Cao, Jian

    2014-09-01

    In the field of the chromatographic peak identification of the transformer oil, the traditional first-order derivative requires slope threshold to achieve peak identification. In terms of its shortcomings of low automation and easy distortion, the first-order derivative method was improved by applying the moving average iterative method and the normalized analysis techniques to identify the peaks. Accurate identification of the chromatographic peaks was realized through using multiple iterations of the moving average of signal curves and square wave curves to determine the optimal value of the normalized peak identification parameters, combined with the absolute peak retention times and peak window. The experimental results show that this algorithm can accurately identify the peaks and is not sensitive to the noise, the chromatographic peak width or the peak shape changes. It has strong adaptability to meet the on-site requirements of online monitoring devices of dissolved gases in transformer oil.

  4. Mathematical functions for the representation of chromatographic peaks.

    Science.gov (United States)

    Di Marco, V B; Bombi, G G

    2001-10-05

    About ninety empirical functions for the representation of chromatographic peaks have been collected and tabulated. The table, based on almost 200 references, reports for every function: (1) the most used name; (2) the most convenient equation, with the existence intervals for the adjustable parameters and for the independent variable; (3) the applications; (4) the mathematical properties, in relation to the possible applications. The list includes also equations originally proposed to represent peaks obtained in other analytical techniques (e.g. in spectroscopy), which in many instances have proved useful in representing chromatographic peaks as well; the built-in functions employed in some commercial peak-fitting software packages were included, too. Some of the most important chromatographic functions, i.e. the Exponentially Modified Gaussian, the Poisson, the Log-normal, the Edgeworth/Cramér series and the Gram/Charlier series, have been reviewed and commented in more detail.

  5. Discriminate Modelling of Peak and Off-Peak Motorway Capacity

    Directory of Open Access Journals (Sweden)

    Hashim Mohammed Alhassan

    2013-02-01

    Full Text Available Traffic theory is concerned with the movement of discrete objects in real time over a finite network in 2 Dimensions. It is compatible with or dependent on fundamental diagram of traffic. Without question traffic flow is an essential quantitative parameter that is used in planning, designs and roadway improvements.  Road capacity is significant because it is an important indicator of road performance and can point road managers in the right road maintenance and traffic management direction. In this paper four direct empirical capacity measurement methods have been considered. To test the efficacy of each method, data for peak period, off-peak and transition to peak have been used. The headway and the volume methods lack predictive capability and are suitable only for current assessment of flow rates.  The product limit method is weak in its predictive capability in view of the arbitrariness in the selection of the capacity value. It is also an extreme value method; hence not all volume data can be used with this method. The fundamental diagram method has good predictive capability and furnishes capacity values consistent with the standard of the facility. Unlike other methods, it does not rely on bottleneck conditions to deliver the capacity value.  The paper concluded that each method is uniquely suited to prevailing conditions and can be so employed.

  6. A simple multi-scale Gaussian smoothing-based strategy for automatic chromatographic peak extraction.

    Science.gov (United States)

    Fu, Hai-Yan; Guo, Jun-Wei; Yu, Yong-Jie; Li, He-Dong; Cui, Hua-Peng; Liu, Ping-Ping; Wang, Bing; Wang, Sheng; Lu, Peng

    2016-06-24

    Peak detection is a critical step in chromatographic data analysis. In the present work, we developed a multi-scale Gaussian smoothing-based strategy for accurate peak extraction. The strategy consisted of three stages: background drift correction, peak detection, and peak filtration. Background drift correction was implemented using a moving window strategy. The new peak detection method is a variant of the system used by the well-known MassSpecWavelet, i.e., chromatographic peaks are found at local maximum values under various smoothing window scales. Therefore, peaks can be detected through the ridge lines of maximum values under these window scales, and signals that are monotonously increased/decreased around the peak position could be treated as part of the peak. Instrumental noise was estimated after peak elimination, and a peak filtration strategy was performed to remove peaks with signal-to-noise ratios smaller than 3. The performance of our method was evaluated using two complex datasets. These datasets include essential oil samples for quality control obtained from gas chromatography and tobacco plant samples for metabolic profiling analysis obtained from gas chromatography coupled with mass spectrometry. Results confirmed the reasonability of the developed method.

  7. Computation of distribution of minimum resolution for log-normal distribution of chromatographic peak heights.

    Science.gov (United States)

    Davis, Joe M

    2011-10-28

    General equations are derived for the distribution of minimum resolution between two chromatographic peaks, when peak heights in a multi-component chromatogram follow a continuous statistical distribution. The derivation draws on published theory by relating the area under the distribution of minimum resolution to the area under the distribution of the ratio of peak heights, which in turn is derived from the peak-height distribution. Two procedures are proposed for the equations' numerical solution. The procedures are applied to the log-normal distribution, which recently was reported to describe the distribution of component concentrations in three complex natural mixtures. For published statistical parameters of these mixtures, the distribution of minimum resolution is similar to that for the commonly assumed exponential distribution of peak heights used in statistical-overlap theory. However, these two distributions of minimum resolution can differ markedly, depending on the scale parameter of the log-normal distribution. Theory for the computation of the distribution of minimum resolution is extended to other cases of interest. With the log-normal distribution of peak heights as an example, the distribution of minimum resolution is computed when small peaks are lost due to noise or detection limits, and when the height of at least one peak is less than an upper limit. The distribution of minimum resolution shifts slightly to lower resolution values in the first case and to markedly larger resolution values in the second one. The theory and numerical procedure are confirmed by Monte Carlo simulation. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Multivariate curve resolution based chromatographic peak alignment combined with parallel factor analysis to exploit second-order advantage in complex chromatographic measurements.

    Science.gov (United States)

    Parastar, Hadi; Akvan, Nadia

    2014-03-13

    In the present contribution, a new combination of multivariate curve resolution-correlation optimized warping (MCR-COW) with trilinear parallel factor analysis (PARAFAC) is developed to exploit second-order advantage in complex chromatographic measurements. In MCR-COW, the complexity of the chromatographic data is reduced by arranging the data in a column-wise augmented matrix, analyzing using MCR bilinear model and aligning the resolved elution profiles using COW in a component-wise manner. The aligned chromatographic data is then decomposed using trilinear model of PARAFAC in order to exploit pure chromatographic and spectroscopic information. The performance of this strategy is evaluated using simulated and real high-performance liquid chromatography-diode array detection (HPLC-DAD) datasets. The obtained results showed that the MCR-COW can efficiently correct elution time shifts of target compounds that are completely overlapped by coeluted interferences in complex chromatographic data. In addition, the PARAFAC analysis of aligned chromatographic data has the advantage of unique decomposition of overlapped chromatographic peaks to identify and quantify the target compounds in the presence of interferences. Finally, to confirm the reliability of the proposed strategy, the performance of the MCR-COW-PARAFAC is compared with the frequently used methods of PARAFAC, COW-PARAFAC, multivariate curve resolution-alternating least squares (MCR-ALS), and MCR-COW-MCR. In general, in most of the cases the MCR-COW-PARAFAC showed an improvement in terms of lack of fit (LOF), relative error (RE) and spectral correlation coefficients in comparison to the PARAFAC, COW-PARAFAC, MCR-ALS and MCR-COW-MCR results.

  9. Multiple chromatographic peaks of phenylalanyl-tRNA associated with spontaneous hydrolysis of Y base during isolation.

    Science.gov (United States)

    Mushinski, J F; Marini, M

    1977-06-17

    In contrast to the single phenylalanyl-tRNA found in normal cells, some tumours are known to have more than one phenylalanine isoacceptor. However, during certain steps in tRNA isolation from normal or tumour tissue, additional chromatographic peaks can be artificially produced which may be confused with the tumour-specific Phe-tRNA. Such procedures as extraction with unbuffered phenol and unbuffered gel filtration chromatography appear to produce adventitious isoacceptors by hydrolysis of Y base.

  10. ASSESSING PEAK AEROBIC CAPACITY IN DUTCH LAW ENFORCEMENT OFFICERS

    NARCIS (Netherlands)

    Wittink, Harriet; Takken, Tim; de Groot, Janke; Reneman, Michiel; Peters, Roelof; Vanhees, Luc

    2015-01-01

    Objectives: To cross-validate the existing peak rate of oxygen consumption (VO2peak) prediction equations in Dutch law enforcement officers and to determine whether these prediction equations can be used to predict VO2peak for groups and in a single individual. A further objective was to report norm

  11. Assessing peak aerobic capacity in Dutch law enforcement officers

    Directory of Open Access Journals (Sweden)

    Harriet Wittink

    2015-06-01

    Full Text Available Objectives: To cross-validate the existing peak rate of oxygen consumption (VO2peak prediction equations in Dutch law enforcement officers and to determine whether these prediction equations can be used to predict VO2peak for groups and in a single individual. A further objective was to report normative absolute and relative VO2peak values of a sample of law enforcement officers in the Netherlands. Material and Methods: The peak rate of oxygen consumption (ml×kg–1×min–1 was measured using a maximal incremental bicycle test in 1530 subjects, including 1068 male and 461 female police officers. Validity of the prediction equations for groups was assessed by comparing predicted VO2peak with measured VO2peak using paired t-tests. For individual differences limits of agreement (LoA were calculated. Equations were considered valid for individuals when the difference between measured and predicted VO2peak did not exceed ±1 metabolic equivalent (MET in 95% of individuals. Results: None of the equations met the validity criterion of 95% of individuals having ±1 MET difference or less than the measured value. Limits of agreement (LoAs were large in all predictions. At the individual level, none of the equations were valid predictors of VO2peak (ml×kg–1×min–1. Normative values for Dutch law enforcement officers were presented. Conclusions: Substantial differences between measured and predicted VO2peak (ml×kg–1×min–1 were found. Most tested equations were invalid predictors of VO2peak at group level and all were invalid at individual levels.

  12. Assessing peak aerobic capacity in Dutch law enforcement officers.

    Science.gov (United States)

    Wittink, Harriet; Takken, Tim; de Groot, Janke; Reneman, Michiel; Peters, Roelof; Vanhees, Luc

    2015-01-01

    To cross-validate the existing peak rate of oxygen consumption (VO2peak) prediction equations in Dutch law enforcement officers and to determine whether these prediction equations can be used to predict VO2peak for groups and in a single individual. A further objective was to report normative absolute and relative VO2peak values of a sample of law enforcement officers in the Netherlands. The peak rate of oxygen consumption (ml×kg-1×min-1) was measured using a maximal incremental bicycle test in 1530 subjects, including 1068 male and 461 female police officers. Validity of the prediction equations for groups was assessed by comparing predicted VO2peak with measured VO2peak using paired t-tests. For individual differences limits of agreement (LoA) were calculated. Equations were considered valid for individuals when the difference between measured and predicted VO2peak did not exceed ±1 metabolic equivalent (MET) in 95% of individuals. None of the equations met the validity criterion of 95% of individuals having ±1 MET difference or less than the measured value. Limits of agreement (LoAs) were large in all predictions. At the individual level, none of the equations were valid predictors of VO2peak (ml×kg-1×min-1). Normative values for Dutch law enforcement officers were presented. Substantial differences between measured and predicted VO2peak (ml×kg-1×min-1) were found. Most tested equations were invalid predictors of VO2peak at group level and all were invalid at individual levels. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  13. Correlation between Chromatograph Capacity Factors and Structural Parameters of Indole Derivatives

    Institute of Scientific and Technical Information of China (English)

    ZHENG Qing; WANG Zun-Yao; SUN Li; YU Bin

    2005-01-01

    Sixteen indole derivatives have been computed at B3LYP/6-311G** level using density functional theory (DFT). Based on linear solvation energy theory, the structural para- meters were employed to present correlation between the parameters of chromatograph capacity factor (CCF) and molecular structural parameters. As a result, the correlation equation of the reversed phased high performance liquid chromatograph capacity factor to the intercept lgk'w and slope S of CCF were obtained, from which the correlation coefficients of lgk'w to the structural parameters are r2 = 0.9596 and q2 = 0.9262. While the correlation coefficients of the parameter S with structures are r2 = 0.9750 and q2 = 0.9252. Moreover, the effect of water as solvent on the present two models was also considered using SCRF method, and the result shows that the predicting capacity of correlation equation of lgkw' increases, while that of the model for S decreases slightly. Both two correlation equations achieved in this work are more advantageous than those using theoretical descriptors from molecular connectivity indices.

  14. Free-space optical communications with peak and average constraints: High SNR capacity approximation

    KAUST Repository

    Chaaban, Anas

    2015-09-07

    The capacity of the intensity-modulation direct-detection (IM-DD) free-space optical channel with both average and peak intensity constraints is studied. A new capacity lower bound is derived by using a truncated-Gaussian input distribution. Numerical evaluation shows that this capacity lower bound is nearly tight at high signal-to-noise ratio (SNR), while it is shown analytically that the gap to capacity upper bounds is a small constant at high SNR. In particular, the gap to the high-SNR asymptotic capacity of the channel under either a peak or an average constraint is small. This leads to a simple approximation of the high SNR capacity. Additionally, a new capacity upper bound is derived using sphere-packing arguments. This bound is tight at high SNR for a channel with a dominant peak constraint.

  15. The Application of Multiobjective Genetic Algorithm to the Parameter Optimization of Single-Well Potential Stochastic Resonance Algorithm Aimed at Simultaneous Determination of Multiple Weak Chromatographic Peaks

    Directory of Open Access Journals (Sweden)

    Haishan Deng

    2014-01-01

    Full Text Available Simultaneous determination of multiple weak chromatographic peaks via stochastic resonance algorithm attracts much attention in recent years. However, the optimization of the parameters is complicated and time consuming, although the single-well potential stochastic resonance algorithm (SSRA has already reduced the number of parameters to only one and simplified the process significantly. Even worse, it is often difficult to keep amplified peaks with beautiful peak shape. Therefore, multiobjective genetic algorithm was employed to optimize the parameter of SSRA for multiple optimization objectives (i.e., S/N and peak shape and multiple chromatographic peaks. The applicability of the proposed method was evaluated with an experimental data set of Sudan dyes, and the results showed an excellent quantitative relationship between different concentrations and responses.

  16. Characterization of peak capacity of microbore liquid chromatography columns using gradient kinetic plots.

    Science.gov (United States)

    Hetzel, Terence; Blaesing, Christina; Jaeger, Martin; Teutenberg, Thorsten; Schmidt, Torsten C

    2017-02-17

    The performance of micro-liquid chromatography columns with an inner diameter of 0.3mm was investigated on a dedicated micro-LC system for gradient elution. Core-shell as well as fully porous particle packed columns were compared on the basis of peak capacity and gradient kinetic plot limits. The results for peak capacity showed the superior performance of columns packed with sub-2μm fully porous particles compared to 3.0μm fully porous and 2.7μm core-shell particles within a range of different gradient time to column void time ratios. For ultra-fast chromatography a maximum peak capacity of 16 can be obtained using a 30s gradient for the sub-2μm fully porous particle packed column. A maximum peak capacity of 121 can be achieved using a 5min gradient. In addition, the influence of an alternative detector cell on the basis of optical waveguide technology and contributing less to system variance was investigated showing an increased peak capacity for all applied gradient time/column void time ratios. Finally, the influence of pressure was evaluated indicating increased peak capacity for maximum performance whereas a limited benefit for ultra-fast chromatography with gradient times below 30s was observed. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Impacts of Climate Change on Electric Transmission Capacity and Peak Electricity Load in the United States

    Science.gov (United States)

    Chester, M.; Bartos, M. D.; Eisenberg, D. A.; Gorman, B.; Johnson, N.

    2015-12-01

    Climate change may hinder future electricity reliability by reducing electric transmission capacity while simultaneously increasing electricity demand. This study estimates potential climate impacts to electric transmission capacity and peak electricity load in the United States. Electric power cables suffer decreased transmission capacity as they get hotter; similarly, during the summer peak period, electricity demand typically increases with hotter ambient air temperatures due to increased cooling loads. As atmospheric carbon concentrations increase, higher air temperatures may strain power infrastructure by reducing transmission capacity and increasing peak electricity loads. Taken together, these coincident impacts may have unpredictable consequences for electric power reliability. We estimate the effects of climate change on both the rated capacity of transmission infrastructure and expected electricity demand for 120 electrical utilities across the United States. We estimate climate-attributable capacity reductions to transmission lines by constructing thermal models of representative conductors, then forcing these models with downscaled CMIP5 temperature projections to determine the relative change in rated ampacity over the twenty-first century. Next, we assess the impact of climate change on electricity demand by using historical relationships between ambient temperature and utility-scale summertime peak load to estimate the extent to which climate change will incur additional peak load increases. We use downscaled temperature projections from 11 CMIP5 GCM models under 3 atmospheric carbon scenarios. We find that by mid-century (2040-2060), climate change may reduce average summertime transmission capacity by 4-6% relative to the 1990-2010 reference period. At the same time, peak summertime loads may rise by roughly 2-12% on average due to increases in daily maximum air temperature. In the absence of energy efficiency gains, demand-side management programs

  18. The Unified Parkinson's Disease Rating Scale as a predictor of peak aerobic capacity and ambulatory function.

    Science.gov (United States)

    Ivey, Frederick M; Katzel, Leslie I; Sorkin, John D; Macko, Richard F; Shulman, Lisa M

    2012-01-01

    The Unified Parkinson's Disease Rating Scale (UPDRS) is a widely applied index of disease severity. Our objective was to assess the utility of UPDRS for predicting peak aerobic capacity (VO2 peak) and ambulatory function. Participants (n = 70) underwent evaluation for UPDRS (Total and Motor ratings), VO2 peak, 6-minute walk distance (6MW), and 30-foot self-selected walking speed (SSWS). Using regression, we determined the extent to which the Total and Motor UPDRS scores predicted each functional capacity measure after adjusting for age and sex. We also tested whether adding the Hoehn and Yahr scale (H-Y) to the model changed predictive power of the UPDRS. Adjusted for age and sex, both the Total UPDRS and Motor UPDRS subscale failed to predict VO2 peak. The Total UPDRS did weakly predict 6MW and SSWS (both p UPDRS subscale did not predict these ambulatory function tests. After adding H-Y to the model, Total UPDRS was no longer an independent predictor of 6MW but remained a predictor of SSWS. We conclude that Total and Motor UPDRS rating scales do not predict VO2 peak, but that a weak relationship exists between Total UPDRS and measures of ambulatory function.

  19. Non-parametric linear regression of discrete Fourier transform convoluted chromatographic peak responses under non-ideal conditions of internal standard method.

    Science.gov (United States)

    Korany, Mohamed A; Maher, Hadir M; Galal, Shereen M; Fahmy, Ossama T; Ragab, Marwa A A

    2010-11-15

    This manuscript discusses the application of chemometrics to the handling of HPLC response data using the internal standard method (ISM). This was performed on a model mixture containing terbutaline sulphate, guaiphenesin, bromhexine HCl, sodium benzoate and propylparaben as an internal standard. Derivative treatment of chromatographic response data of analyte and internal standard was followed by convolution of the resulting derivative curves using 8-points sin x(i) polynomials (discrete Fourier functions). The response of each analyte signal, its corresponding derivative and convoluted derivative data were divided by that of the internal standard to obtain the corresponding ratio data. This was found beneficial in eliminating different types of interferences. It was successfully applied to handle some of the most common chromatographic problems and non-ideal conditions, namely: overlapping chromatographic peaks and very low analyte concentrations. For example, a significant change in the correlation coefficient of sodium benzoate, in case of overlapping peaks, went from 0.9975 to 0.9998 on applying normal conventional peak area and first derivative under Fourier functions methods, respectively. Also a significant improvement in the precision and accuracy for the determination of synthetic mixtures and dosage forms in non-ideal cases was achieved. For example, in the case of overlapping peaks guaiphenesin mean recovery% and RSD% went from 91.57, 9.83 to 100.04, 0.78 on applying normal conventional peak area and first derivative under Fourier functions methods, respectively. This work also compares the application of Theil's method, a non-parametric regression method, in handling the response ratio data, with the least squares parametric regression method, which is considered the de facto standard method used for regression. Theil's method was found to be superior to the method of least squares as it assumes that errors could occur in both x- and y-directions and

  20. A tool to evaluate correspondence between extraction ion chromatographic peaks and peptide-spectrum matches in shotgun proteomics experiments.

    Science.gov (United States)

    Ruse, Cristian I; Peacock, Samantha; Ghiban, Cornel; Rivera, Keith; Pappin, Darryl J; Leopold, Peter

    2013-08-01

    Chromatographed peptide signals form the basis of further data processing that eventually results in functional information derived from data-dependent bottom-up proteomics assays. We seek to rank LC/MS parent ions by the quality of their extracted ion chromatograms. Ranked extracted ion chromatograms act as an intuitive physical/chemical preselection filter to improve the quality of MS/MS fragment scans submitted for database search. We identify more than 4900 proteins when considering detector shifts of less than 7 ppm. High quality parent ions for which the database search yields no hits become candidates for subsequent unrestricted analysis for PTMs. Following this rational approach, we prioritize identification of more than 5000 spectrum matches from modified peptides and confirmed the presence of acetylaldehyde-modified His/Lys. We present a logical workflow that scores data-dependent selected ion chromatograms and leverage information about semianalytical LC/LC dimension prior to MS. Our method can be successfully used to identify unexpected modifications in peptides with excellent chromatography characteristics, independent of fragmentation pattern and activation methods. We illustrate analysis of ion chromatograms detected in two different modes by RF linear ion trap and electrostatic field orbitrap.

  1. Maintained peak leg and pulmonary VO2 despite substantial reduction in muscle mitochondrial capacity.

    Science.gov (United States)

    Boushel, R; Gnaiger, E; Larsen, F J; Helge, J W; González-Alonso, J; Ara, I; Munch-Andersen, T; van Hall, G; Søndergaard, H; Saltin, B; Calbet, J A L

    2015-12-01

    We recently reported the circulatory and muscle oxidative capacities of the arm after prolonged low-intensity skiing in the arctic (Boushel et al., 2014). In the present study, leg VO2 was measured by the Fick method during leg cycling while muscle mitochondrial capacity was examined on a biopsy of the vastus lateralis in healthy volunteers (7 male, 2 female) before and after 42 days of skiing at 60% HR max. Peak pulmonary VO2 (3.52 ± 0.18 L.min(-1) pre vs 3.52 ± 0.19 post) and VO2 across the leg (2.8 ± 0.4L.min(-1) pre vs 3.0 ± 0.2 post) were unchanged after the ski journey. Peak leg O2 delivery (3.6 ± 0.2 L.min(-1) pre vs 3.8 ± 0.4 post), O2 extraction (82 ± 1% pre vs 83 ± 1 post), and muscle capillaries per mm(2) (576 ± 17 pre vs 612 ± 28 post) were also unchanged; however, leg muscle mitochondrial OXPHOS capacity was reduced (90 ± 3 pmol.sec(-1) .mg(-1) pre vs 70 ± 2 post, P VO2 can be sustained with a substantial reduction in mitochondrial OXPHOS capacity. This is achieved at a similar O2 delivery and a higher relative ADP-stimulated mitochondrial respiration at a higher mitochondrial p50. These findings support the concept that muscle mitochondrial respiration is submaximal at VO2max , and that mitochondrial volume can be downregulated by chronic energy demand.

  2. 联用色谱完全重叠峰的解析方法%Resolution Methods of Hyphenated Embedded Chromatographic Peaks

    Institute of Scientific and Technical Information of China (English)

    陈迪钊; 毛新平

    2000-01-01

    Based on orthogonal projection technique and constrained peak shape condition, three kind of new methods to resolve completely overalapping chromatographic peaks are proposed in this paper. They are constrained peak shape and curve fitting resolution(CPSCF), iterative orthogonal projection resolution(IOP) and rank annihilation factor analysis(RAFA). If the constrain conditions is satisfied on hyphenated chromatography data matrics, these methods can be proved to be completely possible for them to be used on the resolution of spectra for embedded and concentration profiles for embedding peaks.%基于正交投影技术和约束峰形条件,本文提出了三种完全重叠色谱峰的解析方法,峰形约束曲线拟合解析(CPSCF),交替正交投影(IOP)和秩消失因子分析(RAFA)。对联用色谱数据阵如果约束条件得到满足,这些方法能被证明用于被嵌人组分的光谱和嵌入组分的浓度曲线分辨是完全可能地。

  3. Potential of energy-oriented network optimisation: Switching off over-capacity in off-peak hours

    NARCIS (Netherlands)

    Litjens, R.; Jorguseski, L.

    2010-01-01

    Mobile communication networks are usually planned to provide some minimum service quality level during peak traffic hours. Consequently, in off-peak hours, when traffic loads are lower, the network is characterised by over-capacity, in the sense that same service quality targets can typically be sat

  4. Potential of energy-oriented network optimisation: Switching off over-capacity in off-peak hours

    NARCIS (Netherlands)

    Litjens, R.; Jorguseski, L.

    2010-01-01

    Mobile communication networks are usually planned to provide some minimum service quality level during peak traffic hours. Consequently, in off-peak hours, when traffic loads are lower, the network is characterised by over-capacity, in the sense that same service quality targets can typically be

  5. The Unified Parkinson’s Disease Rating Scale as a predictor of peak aerobic capacity and ambulatory function

    OpenAIRE

    Frederick M. Ivey, PhD; Leslie I. Katzel, MD, PhD; John D. Sorkin, MD, PhD; Richard F. Macko, MD; Lisa M. Shulman, MD

    2012-01-01

    The Unified Parkinson’s Disease Rating Scale (UPDRS) is a widely applied index of disease severity. Our objective was to assess the utility of UPDRS for predicting peak aerobic capacity (VO2 peak) and ambulatory function. Participants (n = 70) underwent evaluation for UPDRS (Total and Motor ratings), VO2 peak, 6-minute walk distance (6MW), and 30-foot self-selected walking speed (SSWS). Using regression, we determined the extent to which the Total and Motor UPDRS scores predicted each functio...

  6. Efficient fabrication of high-capacity immobilized metal ion affinity chromatographic media: The role of the dextran-grafting process and its manipulation.

    Science.gov (United States)

    Zhao, Lan; Zhang, Jingfei; Huang, Yongdong; Li, Qiang; Zhang, Rongyue; Zhu, Kai; Suo, Jia; Su, Zhiguo; Zhang, Zhigang; Ma, Guanghui

    2016-03-01

    Novel high-capacity Ni(2+) immobilized metal ion affinity chromatographic media were prepared through the dextran-grafting process. Dextran was grafted to an allyl-activated agarose-based matrix followed by functionalization for the immobilized metal ion affinity chromatographic media. With elaborate regulation of the allylation degree, dextran was completely or partly grafted to agarose microspheres, namely, completely dextran-grafted agarose microspheres and partly dextran-grafted ones, respectively. Confocal laser scanning microscope results demonstrated that a good adjustment of dextran-grafting degree was achieved, and dextran was distributed uniformly in whole completely dextran-grafted microspheres, while just distributed around the outside of the partly dextran-grafted ones. Flow hydrodynamic properties were improved greatly after the dextran-grafting process, and the flow velocity increased by about 30% compared with that of a commercial chromatographic medium (Ni Sepharose FF). A significant improvement of protein binding performance was also achieved by the dextran-grafting process, and partly dextran-grafted Ni(2+) chelating medium had a maximum binding capacity for His-tagged lactate dehydrogenase about 2.5 times higher than that of Ni Sepharose FF. The results indicated that this novel chromatographic medium is promising for applications in high-efficiency and large-scale protein purification.

  7. Marrying Step Feed with Secondary Clarifier Improvements to Significantly Increase Peak Wet Weather Treatment Capacity: An Integrated Methodology.

    Science.gov (United States)

    Daigger, Glen T; Siczka, John S; Smith, Thomas F; Frank, David A; McCorquodale, J A

    2017-08-01

      The need to increase the peak wet weather secondary treatment capacity of the City of Akron, Ohio, Water Reclamation Facility (WRF) provided the opportunity to test an integrated methodology for maximizing the peak wet weather secondary treatment capacity of activated sludge systems. An initial investigation, consisting of process modeling of the secondary treatment system and computational fluid dynamics (CFD) analysis of the existing relatively shallow secondary clarifiers (3.3 and 3.7 m sidewater depth in 30.5 m diameter units), indicated that a significant increase in capacity from 416 000 to 684 000 m3/d or more was possible by adding step feed capabilities to the existing bioreactors and upgrading the existing secondary clarifiers. One of the six treatment units at the WRF was modified, and an extensive 2-year testing program was conducted to determine the total peak wet weather secondary treatment capacity achievable. The results demonstrated that a peak wet weather secondary treatment capacity approaching 974 000 m3/d is possible as long as secondary clarifier solids and hydraulic loadings could be separately controlled using the step feed capability provided. Excellent sludge settling characteristics are routinely experienced at the City of Akron WRF, raising concerns that the identified peak wet weather secondary treatment capacity could not be maintained should sludge settling characteristics deteriorate for some reason. Computational fluid dynamics analysis indicated that the impact of the deterioration of sludge settling characteristics could be mitigated and the identified peak wet weather secondary treatment capacity maintained by further use of the step feed capability provided to further reduce secondary clarifier solids loading rates at the identified high surface overflow rates. The results also demonstrated that effluent limits not only for total suspended solids (TSS) and five-day carbonaceous biochemical oxygen demand (cBOD5) could be

  8. Impact of obesity and Down syndrome on peak heart rate and aerobic capacity in youth and adults.

    Science.gov (United States)

    Wee, Sang Ouk; Pitetti, Kenneth H; Goulopoulou, Styliani; Collier, Scott R; Guerra, Myriam; Baynard, Tracy

    2014-10-24

    Individuals with Down syndrome (DS) exhibit reduced aerobic capacity with reduced peak heart rate (HRpeak). This condition is often coexistent with higher level of obesity compared to individuals without DS. The purpose of this study is to investigate the effects of obesity and Down syndrome (DS) on peak heart rate (HRpeak) and peak oxygen consumption (VO2peak) in children and adults both with and without intellectual disabilities (ID)s. VO2peak and HRpeak from individualized treadmill tests on 654 individuals were analyzed. Body mass index was used to categorize individuals' weight status using standard cut-offs. DS groups had the lowest HRpeak (167bpm±14, pObesity did not affect HRpeak among adults and children with DS. VO2peak was lower among individuals with DS (25.2mL/kg/min±6.3, pObese adults with DS had lower VO2peak (24.3mL/kg/min±6.9, p=0.001) compared to the normal weight (26.7±7.1mL/kg/min) and overweight groups (27.0mL/kg/min±6.1) with DS. Conversely, in children, obesity level did not impact VO2peak in individuals with DS. Our results suggest that DS attenuates both VO2peak and HRpeak, regardless of obesity status and age group. However, obesity was associated with lower VO2peak in all adults, but not in children with DS.

  9. Relative Economic Merits of Storage and Combustion Turbines for Meeting Peak Capacity Requirements under Increased Penetration of Solar Photovoltaics

    Energy Technology Data Exchange (ETDEWEB)

    Denholm, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States); Diakov, Victor [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-09-01

    Batteries with several hours of capacity provide an alternative to combustion turbines for meeting peak capacity requirements. Even when compared to state-of-the-art highly flexible combustion turbines, batteries can provide a greater operational value, which is reflected in a lower system-wide production cost. By shifting load and providing operating reserves, batteries can reduce the cost of operating the power system to a traditional electric utility. This added value means that, depending on battery life, batteries can have a higher cost than a combustion turbine of equal capacity and still produce a system with equal or lower overall life-cycle cost. For a utility considering investing in new capacity, the cost premium for batteries is highly sensitive to a variety of factors, including lifetime, natural gas costs, PV penetration, and grid generation mix. In addition, as PV penetration increases, the net electricity demand profile changes, which may reduce the amount of battery energy capacity needed to reliably meet peak demand.

  10. Maintained peak leg and pulmonary VO2 despite substantial reduction in muscle mitochondrial capacity

    DEFF Research Database (Denmark)

    Boushel, Robert; Gnaiger, E.; Larsen, F. J.;

    2015-01-01

    We recently reported the circulatory and muscle oxidative capacities of the arm after prolonged low-intensity skiing in the arctic (Boushel et al., 2014). In the present study, leg VO2 was measured by the Fick method during leg cycling while muscle mitochondrial capacity was examined on a biopsy...... of the vastus lateralis in healthy volunteers (7 male, 2 female) before and after 42 days of skiing at 60% HR max. Peak pulmonary VO2 (3.52 ± 0.18 L.min-1 pre vs 3.52 ± 0.19 post) and VO2 across the leg (2.8 ± 0.4L.min-1 pre vs 3.0 ± 0.2 post) were unchanged after the ski journey. Peak leg O2 delivery (3.6 ± 0...

  11. Load controller and method to enhance effective capacity of a photovotaic power supply using a dynamically determined expected peak loading

    Science.gov (United States)

    Perez, Richard

    2003-04-01

    A load controller and method are provided for maximizing effective capacity of a non-controllable, renewable power supply coupled to a variable electrical load also coupled to a conventional power grid. Effective capacity is enhanced by monitoring power output of the renewable supply and loading, and comparing the loading against the power output and a load adjustment threshold determined from an expected peak loading. A value for a load adjustment parameter is calculated by subtracting the renewable supply output and the load adjustment parameter from the current load. This value is then employed to control the variable load in an amount proportional to the value of the load control parameter when the parameter is within a predefined range. By so controlling the load, the effective capacity of the non-controllable, renewable power supply is increased without any attempt at operational feedback control of the renewable supply. The expected peak loading of the variable load can be dynamically determined within a defined time interval with reference to variations in the variable load.

  12. Comparative studies of peak intensities and chromatographic separation of proteolytic digests, PTMs, and intact proteins obtained by nanoLC-ESI MS analysis at room and elevated temperatures.

    Science.gov (United States)

    Moskovets, Eugene V; Ivanov, Alexander R

    2016-06-01

    This work demonstrates that the chromatographic separation performed at highly stabilized elevated temperature results in significant improvements in sensitivity, quantitative accuracy, chromatographic resolution, and run-to-run reproducibility of nanoLC-MS analysis of complex peptides mixtures. A newly developed platform was shown to provide conditions for accurate temperature stabilization and temperature homogeneity when performing nanoLC-ESI MS analysis. We quantitatively assessed and compared the recovery of peptides and small proteins from nanoLC columns at room and elevated temperatures. We found that analyses performed at highly stabilized elevated temperatures led to improved detection sensitivity, reproducibility, and chromatographic resolution in reversed-phase LC separation of unmodified peptides (both hydrophilic and hydrophobic), post-translationally modified peptides (O-phosphorylated), and small intact proteins. The analytical benefits of elevated temperatures for qualitative and quantitative proteomic LC-MS profiling were demonstrated using mixtures of synthetic peptides, tryptic digests of mixtures of model proteins, and digested total lysates of isolated rat kidney mitochondria. The effect of elevated temperature on the ion suppression was also demonstrated. Graphical Abstract A fragment of overlaid LC retention time-m/z planar views demonstrates the improved separation performance in the analysis of a complex peptide mixture at elevated temperature. Retention time-m/z 2D peptide features detected at 60 °C (magenta) were matched and aligned with features detected at room temperature (green).

  13. Separation of intact proteins on γ-ray-induced polymethacrylate monolithic columns: A highly permeable stationary phase with high peak capacity for capillary high-performance liquid chromatography with high-resolution mass spectrometry.

    Science.gov (United States)

    Simone, Patrizia; Pierri, Giuseppe; Foglia, Patrizia; Gasparrini, Francesca; Mazzoccanti, Giulia; Capriotti, Anna Laura; Ursini, Ornella; Ciogli, Alessia; Laganà, Aldo

    2016-01-01

    Polymethacrylate-based monolithic capillary columns, prepared by γ-radiation-induced polymerization, were used to optimize the experimental conditions (nature of the organic modifiers, the content of trifluoroacetic acid and the column temperature) in the separation of nine standard proteins with different hydrophobicities and a wide range of molecular weights. Because of the excellent permeability of the monolithic columns, an ion-pair reversed-phase capillary liquid chromatography with high-resolution mass spectrometry method has been developed by coupling the column directly to the mass spectrometer without a flow-split and using a standard electrospray interface. Additionally, the high working flow and concomitant high efficiency of these columns allowed us to employ a longer column (up to 50 cm) and achieve a peak capacity value superior to 1000. This work is motivated by the need to develop new materials for high-resolution chromatographic separation that combine chemical stability at elevated temperatures (up to 75°C) and a broad pH range, with a high peak capacity value. The advantage of the γ-ray-induced monolithic column lies in the batch-to-batch reproducibility and long-term high-temperature stability. Their proven high loading capacity, recovery, good selectivity and high permeability, moreover, compared well with that of a commercially available poly(styrene-divinylbenzene) monolithic column, which confirms that such monolithic supports might facilitate analysis in proteomics.

  14. Moderate-Load Muscular Endurance Strength Training Did Not Improve Peak Power or Functional Capacity in Older Men and Women

    Directory of Open Access Journals (Sweden)

    Simon Walker

    2017-09-01

    Full Text Available The present study determined the effects of muscular endurance strength training on maximum strength and power, functional capacity, muscle activation and hypertrophy in older men and women. Eighty-one men and women acted as an intervention group while 22 acted as non-training controls (age range 64–75 y. Intervention training included super-sets (i.e., paired exercises, immediately performing the second exercises following completion of the first with short rest intervals (30–60 s between sets at an intensity of 50–60% one-repetition maximum (1-RM for 15–20 repetitions. Concentric leg press actions measured maximum strength (1-RM and concentric peak power. Functional capacity was assessed by maximum speed walking tests (i.e., forward walk, backward walk, timed-up-and-go, and stair climb tests. Quadriceps muscle activation was assessed by surface electromyogram and twitch interpolation technique. Vastus lateralis cross-sectional area was measured by panoramic ultrasound. Compared to control, the intervention groups increased maximum strength (1-RM; men: 10 ± 7% vs. 2 ± 3%, women: 14 ± 9% vs. 1 ± 6% both P < 0.01 and vastus lateralis cross-sectional area (men: 6 ± 7% vs. −3 ± 6%, women: 10 ± 10% vs. 0 ± 4% both P < 0.05. But there were no between-group differences in peak power, muscle activation or functional capacity (e.g., stair climb; men: −5 ± 7% vs. −4 ± 3%, women: −5 ± 6% vs. −2 ± 5% both P > 0.05. While benefits occurred during muscular endurance strength training, specific stimuli are probably needed to target all aspects of age-related health.

  15. Improving stability of virus-like particles by ion-exchange chromatographic supports with large pore size: advantages of gigaporous media beyond enhanced binding capacity.

    Science.gov (United States)

    Yu, Mengran; Li, Yan; Zhang, Songping; Li, Xiunan; Yang, Yanli; Chen, Yi; Ma, Guanghui; Su, Zhiguo

    2014-02-28

    Limited binding capacity and low recovery of large size multi-subunits virus-like particles (VLPs) in conventional agarose-gel based chromatographic supports with small pores have long been a bottleneck limiting the large scale purification and application of VLPs. In this study, four anion exchange media including DEAE-Sepharose FF (DEAE-FF), DEAE-Capto, gigaporous DEAE-AP-120nm and DEAE-AP-280nm with average pore diameters of 32nm, 20nm, 120nm and 280nm, respectively, were applied for purification of hepatitis B virus surface antigen (HBsAg) VLPs. Pore size effects of media on the VLPs adsorption equilibrium, adsorption kinetics, dynamic binding capacity (DBC), and recovery were investigated in detail. According to the confocal laser scanning microscopy observation, adsorption of the VLPs in DEAE-FF and DEAE-Capto was mostly confined to a thin shell on the outer surface of the beads, leaving the underlying pore space and the binding sites inaccessibly, while the large pores in gigaporous media enabled the VLPs to access to the interior pore spaces by diffusion transport efficiently. Compared to the most widely used DEAE-FF, gigaporous media DEAE-AP-280nm gained about 12.9 times increase in static adsorption capacity, 8.0 times increase in DBC, and 11.4 times increase in effective pore diffusivity. Beyond increasing the binding capacity and enhancing the mass transfer, the gigaporous structure also significantly improved the stability of the VLPs during intensive adsorption-desorption process by lowing the multi-point interaction between the VLPs and binding sites in the pores. At 2.0mg/mL-media loading quantity, about 85.5% VLPs were correctly self-assembled after the chromatography with DEAE-AP-280nm media; oppositely about 85.2% VLPs lost their normal assembly with DEAE-FF due to irreversible disassembly. Comparative investigation was made to study the purifying performance of these four chromatographic media for actual VLPs purification from recombinant

  16. GC×GC-TOF/MS Chromatographic Analysis, Antioxidant Capacity and Phenolic Content of Rosa Canina L. at Different Maturities

    Directory of Open Access Journals (Sweden)

    Dilek Ozyurt

    2016-01-01

    Full Text Available The relationship between food and health has become increasingly significant as consumers now demand healthy, tasty and natural foods which perform a useful function in the body. In Turkey, rose hip (Rosa canina L. is in popular use in foodstuffs such as marmalade, pestil (a traditional Turkish sweet and syrup or in traditional medicine, mainly as herbal tea. The composition, total antioxidant capacity (TAC and total phenolic content (TPC of volatiles of rose hip samples were compared in relation to their stage of maturity and collection location. Rose hip fruit and seed were analyzed using a direct thermal desorption technique coupled with comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GCxGC-TOF/MS. The major components found in the volatile fraction released on extraction were free fatty acids. The various stages of maturity of rose hips (green, light yellow, yellow, orange and red coloured and the place of collection (Istanbul, Mersin, York resulted in some changes in volatile compound speciation, in TAC and TPC levels. Various extraction methods were compared; methanol extraction, traditional hot water infusion and boiling in water. Boiling in water for ten minutes was the method which demonstrated the highest extraction efficiency. TAC and TPC were determined using different electron transfer−based assays; the Cerium (IV ions reducing antioxidant capacity, Cupric Reducing Antioxidant Capacity and Folin-Ciocalteu methods. The highest TAC and TPC were found in the red coloured (fully ripe rose hip fruit, suggesting that colour is a suitable indicator for optimal harvesting time.

  17. Spectrophotometric and chromatographic assessment of contributions of carotenoids and chlorophylls to the total antioxidant capacities of plant foods.

    Science.gov (United States)

    Sözgen Başkan, Kevser; Tütem, Esma; Özer, Nihat; Apak, Reşat

    2013-11-27

    Carotenoids and chlorophylls are photosynthetic compounds and also efficient antioxidants. This study aims to identify and quantify carotenoids and chlorophylls in some vegetables (carrot, tomato, spinach), to measure the total antioxidant capacity (TAC) of these samples with two spectrophotometric methods, to correlate TAC data with carotenoid structure, and to compare the TAC results with HPLC findings. Separation of the individual antioxidant pigments was achieved on a C30 column using a developed gradient elution program involving methanol-acetonitrile (50:50, v/v) with 0.1% (v/v) triethylamine (TEA) (A) and acetone (B) mobile phases. Total antioxidant capacities of the acetone extracts of studied samples, in trolox and β-carotene equivalents, were in the order: spinach > tomato > carrot by both CUPRAC and ABTS methods. CUPRAC responded favorably to both chlorophylls a and b. The TAC calculated with aid of combined HPLC-spectrophotometry was very close to the spectrophotometric value (93-108%) for real samples and synthetic mixtures.

  18. Antioxidant Activity/Capacity Measurement. 3. Reactive Oxygen and Nitrogen Species (ROS/RNS) Scavenging Assays, Oxidative Stress Biomarkers, and Chromatographic/Chemometric Assays.

    Science.gov (United States)

    Apak, Reşat; Özyürek, Mustafa; Güçlü, Kubilay; Çapanoğlu, Esra

    2016-02-10

    There are many studies in which the antioxidant potential of different foods have been analyzed. However, there are still conflicting results and lack of information as a result of unstandardized assay techniques and differences between the principles of the methods applied. The measurement of antioxidant activity, especially in the case of mixtures, multifunctional or complex multiphase systems, cannot be evaluated satisfactorily using a simple antioxidant test due to the many variables influencing the results. In the literature, there are many antioxidant assays that are used to measure the total antioxidant activity/capacity of food materials. In this review, reactive oxygen and nitrogen species (ROS/RNS) scavenging assays are evaluated with respect to their mechanism, advantages, disadvantages, and potential use in food systems. On the other hand, in vivo antioxidant activity (AOA) assays including oxidative stress biomarkers and cellular-based assays are covered within the scope of this review. Finally, chromatographic and chemometric assays are reviewed, focusing on their benefits especially with respect to their time saving, cost-effective, and sensitive nature.

  19. Final Report: Cooling Seasonal Energy and Peak Demand Impacts of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps

    Energy Technology Data Exchange (ETDEWEB)

    Withers, C. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center, Cocoa, FL (United States); Cummings, J. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center, Cocoa, FL (United States); Nigusse, B. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center, Cocoa, FL (United States)

    2016-09-08

    A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied by adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.

  20. Final Report: Cooling Seasonal Energy and Peak Demand Impacts of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps

    Energy Technology Data Exchange (ETDEWEB)

    Withers, C. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center (FSEC), Cocoa, FL (United States); Cummings, J. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center (FSEC), Cocoa, FL (United States); Nigusse, B. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center (FSEC), Cocoa, FL (United States)

    2016-09-01

    A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied by adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.

  1. Study on the performance of different types of three-dimensional chromatographic systems

    NARCIS (Netherlands)

    Davydova, E.; Schoenmakers, P.J.; Vivó-Truyols, G.

    2013-01-01

    The maximum achievable performance of possible types of three-dimensional chromatographic systems (LC x LC x LC) has been investigated. The Pareto-optimization approach was applied to establish a trade-off between three main objectives (total peak capacity, analysis time and dilution of the sample)

  2. Study on the performance of different types of three-dimensional chromatographic systems

    NARCIS (Netherlands)

    Davydova, E.; Schoenmakers, P.J.; Vivó-Truyols, G.

    2013-01-01

    The maximum achievable performance of possible types of three-dimensional chromatographic systems (LC x LC x LC) has been investigated. The Pareto-optimization approach was applied to establish a trade-off between three main objectives (total peak capacity, analysis time and dilution of the sample)

  3. The relationship of aerobic capacity, anaerobic peak power and experience to performance in CrossFit exercise

    OpenAIRE

    Bellar, D; Hatchett, A; Judge, LW; Breaux, ME; Marcus, L.

    2015-01-01

    CrossFit is becoming increasingly popular as a method to increase fitness and as a competitive sport in both the Unites States and Europe. However, little research on this mode of exercise has been performed to date. The purpose of the present investigation involving experienced CrossFit athletes and naïve healthy young men was to investigate the relationship of aerobic capacity and anaerobic power to performance in two representative CrossFit workouts: the first workout was 12 minutes in dur...

  4. Robot-assisted gait training improves brachial–ankle pulse wave velocity and peak aerobic capacity in subacute stroke patients with totally dependent ambulation

    Science.gov (United States)

    Han, Eun Young; Im, Sang Hee; Kim, Bo Ryun; Seo, Min Ji; Kim, Myeong Ok

    2016-01-01

    Abstract Objective: Brachial–ankle pulse wave velocity (baPWV) evaluates arterial stiffness and also predicts early outcome in stroke patients. The objectives of this study were to investigate arterial stiffness of subacute nonfunctional ambulatory stroke patients and to compare the effects of robot-assisted gait therapy (RAGT) combined with rehabilitation therapy (RT) on arterial stiffness and functional recovery with those of RT alone. Method: The RAGT group (N = 30) received 30 minutes of robot-assisted gait therapy and 30 minutes of conventional RT, and the control group (N = 26) received 60 minutes of RT, 5 times a week for 4 weeks. baPWV was measured and calculated using an automated device. The patients also performed a symptom-limited graded exercise stress test using a bicycle ergometer, and parameters of cardiopulmonary fitness were recorded. Clinical outcome measures were categorized into 4 categories: activities of daily living, balance, ambulatory function, and paretic leg motor function and were evaluated before and after the 4-week intervention. Results: Both groups exhibited significant functional recovery in all clinical outcome measures after the 4-week intervention. However, peak aerobic capacity, peak heart rate, exercise tolerance test duration, and baPWV improved only in the RAGT group, and the improvements in baPWV and peak aerobic capacity were more noticeable in the RAGT group than in the control group. Conclusion: Robot-assisted gait therapy combined with conventional rehabilitation therapy represents an effective method for reversing arterial stiffness and improving peak aerobic capacity in subacute stroke patients with totally dependent ambulation. However, further large-scale studies with longer term follow-up periods are warranted to measure the effects of RAGT on secondary prevention after stroke. PMID:27741123

  5. Robot-assisted gait training improves brachial-ankle pulse wave velocity and peak aerobic capacity in subacute stroke patients with totally dependent ambulation: Randomized controlled trial.

    Science.gov (United States)

    Han, Eun Young; Im, Sang Hee; Kim, Bo Ryun; Seo, Min Ji; Kim, Myeong Ok

    2016-10-01

    Brachial-ankle pulse wave velocity (baPWV) evaluates arterial stiffness and also predicts early outcome in stroke patients. The objectives of this study were to investigate arterial stiffness of subacute nonfunctional ambulatory stroke patients and to compare the effects of robot-assisted gait therapy (RAGT) combined with rehabilitation therapy (RT) on arterial stiffness and functional recovery with those of RT alone. The RAGT group (N = 30) received 30 minutes of robot-assisted gait therapy and 30 minutes of conventional RT, and the control group (N = 26) received 60 minutes of RT, 5 times a week for 4 weeks. baPWV was measured and calculated using an automated device. The patients also performed a symptom-limited graded exercise stress test using a bicycle ergometer, and parameters of cardiopulmonary fitness were recorded. Clinical outcome measures were categorized into 4 categories: activities of daily living, balance, ambulatory function, and paretic leg motor function and were evaluated before and after the 4-week intervention. Both groups exhibited significant functional recovery in all clinical outcome measures after the 4-week intervention. However, peak aerobic capacity, peak heart rate, exercise tolerance test duration, and baPWV improved only in the RAGT group, and the improvements in baPWV and peak aerobic capacity were more noticeable in the RAGT group than in the control group. Robot-assisted gait therapy combined with conventional rehabilitation therapy represents an effective method for reversing arterial stiffness and improving peak aerobic capacity in subacute stroke patients with totally dependent ambulation. However, further large-scale studies with longer term follow-up periods are warranted to measure the effects of RAGT on secondary prevention after stroke.

  6. The relationship of aerobic capacity, anaerobic peak power and experience to performance in in CrossFit exercise

    Directory of Open Access Journals (Sweden)

    D Bellar

    2015-11-01

    Full Text Available CrossFit is becoming increasingly popular as a method to increase fitness and as a competitive sport in both the Unites States and Europe. However, little research on this mode of exercise has been performed to date. The purpose of the present investigation involving experienced CrossFit athletes and naïve healthy young men was to investigate the relationship of aerobic capacity and anaerobic power to performance in two representative CrossFit workouts: the first workout was 12 minutes in duration, and the second was based on the total time to complete the prescribed exercise. The participants were 32 healthy adult males, who were either naïve to CrossFit exercise or had competed in CrossFit competitions. Linear regression was undertaken to predict performance on the first workout (time with age, group (naïve or CrossFit athlete, VO 2 max and anaerobic power, which were all significant predictors (p<0.05 in the model. The second workout (repetitions, when examined similarly using regression, only resulted in CrossFit experience as a significant predictor (p<0.05. The results of the study suggest that a history of participation in CrossFit competition is a key component of performance in CrossFit workouts which are representative of those performed in CrossFit, and that, in at least one these workouts, aerobic capacity and anaerobic power are associated with success.

  7. The relationship of aerobic capacity, anaerobic peak power and experience to performance in CrossFit exercise.

    Science.gov (United States)

    Bellar, D; Hatchett, A; Judge, L W; Breaux, M E; Marcus, L

    2015-11-01

    CrossFit is becoming increasingly popular as a method to increase fitness and as a competitive sport in both the Unites States and Europe. However, little research on this mode of exercise has been performed to date. The purpose of the present investigation involving experienced CrossFit athletes and naïve healthy young men was to investigate the relationship of aerobic capacity and anaerobic power to performance in two representative CrossFit workouts: the first workout was 12 minutes in duration, and the second was based on the total time to complete the prescribed exercise. The participants were 32 healthy adult males, who were either naïve to CrossFit exercise or had competed in CrossFit competitions. Linear regression was undertaken to predict performance on the first workout (time) with age, group (naïve or CrossFit athlete), VO2max and anaerobic power, which were all significant predictors (p CrossFit experience as a significant predictor (p CrossFit competition is a key component of performance in CrossFit workouts which are representative of those performed in CrossFit, and that, in at least one these workouts, aerobic capacity and anaerobic power are associated with success.

  8. Optimization and Assessment of Three Different High Performance Liquid Chromatographic Systems for the Combinative Fingerprint Analysis and Multi-Ingredients Quantification of Sangju Ganmao Tablet.

    Science.gov (United States)

    Guo, Meng-Zhe; Han, Jie; He, Dan-Dan; Zou, Jia-Hui; Li, Zheng; Du, Yan; Tang, Dao-Quan

    2017-03-01

    Chromatographic separation is still a critical subject for the quality control of traditional Chinese medicine. In this study, three different high performance liquid chromatographic (HPLC) systems employing commercially available columns packed with 1.8, 3.5 and 5.0 μm particles were respectively developed and optimized for the combinative fingerprint analysis and multi-ingredients quantification of Sangju Ganmao tablet (SGT). Chromatographic parameters including the repeatability of retention time and peak area, symmetry factor, resolution, number of theoretical plates and peak capacity were used to assess the chromatographic performance of different HPLC systems. The optimal chromatographic system using Agilent ZORBAX SB-C18 column (2.1 mm × 100 mm, 3.5 μm) as stationary phase was respectively coupled with diode array detector or mass spectrometry detector for the chromatographic fingerprint analysis and simultaneous quantification or identification of nine compounds of SGT. All the validation data conformed to the acceptable requirements. For the fingerprint analysis, 31 peaks were selected as the common peaks to evaluate the similarities of SGT from 10 different manufacturers using heatmap, hierarchical cluster analysis and principal component analysis. The results demonstrated that the combinations of the quantitative and chromatographic fingerprint analysis offer an efficient way to evaluate the quality consistency of SGT.

  9. Improving Peak Capacity in Fast On-Line Comprehensive Two-Dimensional Liquid Chromatography with Post First Dimension Flow-Splitting

    Science.gov (United States)

    Filgueira, Marcelo R.; Huang, Yuan; Witt, Klaus; Castells, Cecilia; Carr, Peter W.

    2011-01-01

    The use of flow splitters between the two dimensions in on-line comprehensive two dimensional liquid chromatography (LC×LC) has not received very much attention in comparison to their use in GC×GC where they are quite common. In principle, splitting the flow after the first dimension column and performing on-line LC×LC on this constant fraction of the first dimension effluent should allow the two dimensions to be optimized almost independently. When there is no flow splitting any change in the first dimension flow rate has an immediate impact on the second dimension. With a flow splitter one could for example double the flow rate into the first dimension column and do a 1:1 flow split without changing the sample loop size or the sampler’s collection time. Of course, the sensitivity would be diminished but this can be partially compensated by use of a larger injection; this will likely only amount to a small price to pay for this increased resolving power and system flexibility. Among other benefits, we found a 2-fold increase in the corrected 2D peak capacity and the number of observed peaks for a 15 min analysis time by using a post first dimension flow splitter. At a fixed analysis time this improvement results primarily from an increase in the gradient time resulting from the reduced system re-equilibration time and to a smaller extent it is due to the increased peak capacity achieved by full optimization of the first dimension. PMID:22017622

  10. Skeletal muscle-specific expression of PGC-1α-b, an exercise-responsive isoform, increases exercise capacity and peak oxygen uptake.

    Directory of Open Access Journals (Sweden)

    Miki Tadaishi

    Full Text Available BACKGROUND: Maximal oxygen uptake (VO(2max predicts mortality and is associated with endurance performance. Trained subjects have a high VO(2max due to a high cardiac output and high metabolic capacity of skeletal muscles. Peroxisome proliferator-activated receptor γ coactivator 1α (PGC-1α, a nuclear receptor coactivator, promotes mitochondrial biogenesis, a fiber-type switch to oxidative fibers, and angiogenesis in skeletal muscle. Because exercise training increases PGC-1α in skeletal muscle, PGC-1α-mediated changes may contribute to the improvement of exercise capacity and VO(2max. There are three isoforms of PGC-1α mRNA. PGC-1α-b protein, whose amino terminus is different from PGC-1α-a protein, is a predominant PGC-1α isoform in response to exercise. We investigated whether alterations of skeletal muscle metabolism by overexpression of PGC-1α-b in skeletal muscle, but not heart, would increase VO(2max and exercise capacity. METHODOLOGY/PRINCIPAL FINDINGS: Transgenic mice showed overexpression of PGC-1α-b protein in skeletal muscle but not in heart. Overexpression of PGC-1α-b promoted mitochondrial biogenesis 4-fold, increased the expression of fatty acid transporters, enhanced angiogenesis in skeletal muscle 1.4 to 2.7-fold, and promoted exercise capacity (expressed by maximum speed by 35% and peak oxygen uptake by 20%. Across a broad range of either the absolute exercise intensity, or the same relative exercise intensities, lipid oxidation was always higher in the transgenic mice than wild-type littermates, suggesting that lipid is the predominant fuel source for exercise in the transgenic mice. However, muscle glycogen usage during exercise was absent in the transgenic mice. CONCLUSIONS/SIGNIFICANCE: Increased mitochondrial biogenesis, capillaries, and fatty acid transporters in skeletal muscles may contribute to improved exercise capacity via an increase in fatty acid utilization. Increases in PGC-1α-b protein or function

  11. Maximum acceptable weight of lift reflects peak lumbosacral extension moments in a functional capacity evaluation test using free style, stoop and squat lifting.

    Science.gov (United States)

    Kuijer, P P F M; van Oostrom, S H; Duijzer, K; van Dieën, J H

    2012-01-01

    It is unclear whether the maximum acceptable weight of lift (MAWL), a common psychophysical method, reflects joint kinetics when different lifting techniques are employed. In a within-participants study (n = 12), participants performed three lifting techniques--free style, stoop and squat lifting from knee to waist level--using the same dynamic functional capacity evaluation lifting test to assess MAWL and to calculate low back and knee kinetics. We assessed which knee and back kinetic parameters increased with the load mass lifted, and whether the magnitudes of the kinetic parameters were consistent across techniques when lifting MAWL. MAWL was significantly different between techniques (p = 0.03). The peak lumbosacral extension moment met both criteria: it had the highest association with the load masses lifted (r > 0.9) and was most consistent between the three techniques when lifting MAWL (ICC = 0.87). In conclusion, MAWL reflects the lumbosacral extension moment across free style, stoop and squat lifting in healthy young males, but the relation between the load mass lifted and lumbosacral extension moment is different between techniques. Tests of maximum acceptable weight of lift (MAWL) from knee to waist height are used to assess work capacity of individuals with low-back disorders. This article shows that the MAWL reflects the lumbosacral extension moment across free style, stoop and squat lifting in healthy young males, but the relation between the load mass lifted and lumbosacral extension moment is different between techniques. This suggests that standardisation of lifting technique used in tests of the MAWL would be indicated if the aim is to assess the capacity of the low back.

  12. Chromatographic Characterization of Molecularly Imprinted Microspheres Synthesized by Aqueous Microsuspension Polymerization:Influences of pH,Kinds and Concentration of Buffer on Capacity Factors

    Institute of Scientific and Technical Information of China (English)

    赖家平; 卢春阳; 何锡文

    2002-01-01

    Molecularly imprintde microspheres(MIMs) were prepared using 4-aminopyridine(4-AP) as template molecule by aqueous microsuspension polymerization.The MIMs were packed into stainless steel column(250×4.6mmI.D.)for selective separation of 4-aminopyridine (4-AP) and 2-aminopyridine (2-AP).The inftuences of pH,kinds and concentration(c) of buffer on capacity factors were investigated in detail.The relationships of capacity factor(k’)with pH and concentration of buffer are quantitatively described firstly.The effects of pH of phosphate and acetate buffer on capacity factors are very different.The relationship between k’ and pH can be described by the following equation:k’=-8.23 9.23pH-0.99pH2(in phosphate buffer) with R2=0.9775and k’=6.79-3.76pH 0.68pH2(in acetate buffer) with R2=0.9866.Furthermore,the capacity factors were also greatly affected by the concentration of acetate buffer in mobile phase while non-imprinted molecule is poorly changed.It increases with decreasing the concentration of buffer-especially in low concentration buffer(cacetase<0.02mol/L,final concentration in mobile phase).The fit curve of log k’ to log c is described by equation:log k’=-0.571-1.256×log c-0.186×(log c)2 with R2=0.9979.The ratio of acetate buffer to methanol was investigated and the optimal ratio for separation of 4-AP and 2-AP is below 1:7.5(V/V).

  13. Chromatographic Characterization of Molecularly Imprinted Microspheres Synthesized by Aqueous Microsuspension Polymerization: Influences of pH, Kinds and Concentration of Buffer on Capacity Factors

    Institute of Scientific and Technical Information of China (English)

    LAI,Jia-Ping(赖家平); LU,Chun-Yang(卢春阳); HE,Xi-Wen(何锡文)

    2002-01-01

    Moleolarly imprinted microspheres (MIMs) were prepared using 4-aminopyridine (4-AP) as template molecule by aqueous microsuspension polymerization. The MIMs were packed into stainless steel cohmn (250 × 4.6 mm I. D. ) for selective separation of 4-aminopyridine (4-AP) and 2-aminopyridine (2-AP). The influences of pH, kinds and concentration ( c ) of buffer on capacity factors were investigated in detail. The relationships of capacity factor ( k' ) with pH and concentration of buffer are quantitatively described firstly. The effects of pH of phosphate and acetate buffer on capacity factors are very different. The relationship between k' and pH can be described by the following equation: k' = - 8.23 + 9.23 pH- 0.99 pH2 (in phosphate buffer) with R2 = 0.9775 and k' = 6.79 - 3.76 pH + 0.68 pH2(in acetate buffer) with R2=0.9866. Furthermore, the capacity factors were also greatly affected by the concentration of acetate buffer in mobile phase while non-imprinted molecule is poorly changed. It increases with decreasing the concentration of buffer-especially in low concentration buffer ( cacetate < 0.02 mol/L, final concentration in mobile phase). The fit curve of log k' to log c is described by equation: log k'= -0.571- 1.256 × log c - 0.186× (log c)2 with R2 = 0.9979. The ratio of acetate buffer to methanol was investigated and the optimal ratio for separation of 4-AP and 2-AP is below 1:7.5 (V/V).

  14. Comparison of the peak resolution and the stationary phase retention between the satellite and the planetary motions using the coil satellite centrifuge with counter-current chromatographic separation of 4-methylumbelliferyl sugar derivatives.

    Science.gov (United States)

    Shinomiya, Kazufusa; Zaima, Kazumasa; Harada, Yukina; Yasue, Miho; Harikai, Naoki; Tokura, Koji; Ito, Yoichiro

    2017-01-20

    Coil satellite centrifuge (CSC) produces the complex satellite motion consisting of the triplicate rotation of the coiled column around three axes including the sun axis (the angular velocity, ω1), the planet axis (ω2) and the satellite axis (the central axis of the column) (ω3) according to the following formula: ω1=ω2+ω3. Improved peak resolution in the separation of 4-methylumbelliferyl sugar derivatives was achieved using the conventional multilayer coiled columns with ethyl acetate/1-butanol/water (3: 2: 5, v/v) for the lower mobile phase at the combination of the rotation speeds (ω1, ω2, ω3)=(300, 150, 150rpm), and (1:4:5, v/v) for the upper mobile phase at (300:100:200rpm). The effect of the satellite motion on the peak resolution and the stationary phase retention was evaluated by each CSC separation with the different rotation speeds of ω2 and ω3 under the constant revolution speed at ω1=300rpm. With the lower mobile phase, almost constant peak resolution and stationary phase retention were yielded regardless of the change of ω2 and ω3, while with the upper mobile phase these two values were sensitively varied according to the different combination of ω2 and ω3. For example, when ω2=147 or 200rpm is used, no stationary phase was retained in the coiled column while ω2=150rpm could retain enough volume of stationary phase for separation. On the other hand, the combined rotation speeds at (ω1, ω2, ω3)=(300, 300, 0rpm) or (300, 0, 300rpm) produced insufficient peak resolution regardless of the choice of the mobile phase apparently due to the lack of rotation speed except at (300, 0, 300rpm) with the upper mobile phase. At lower rotation speed of ω1=300rpm, better peak resolution and stationary phase retention were obtained by the satellite motion (ω3) than by the planetary motion (ω2), or ω3>ω2. The effect of the hydrophobicity of the two-phase solvent systems on the stationary phase retention was further examined using the n

  15. High-performance liquid chromatographic separation of subcomponents of antimycin A.

    Science.gov (United States)

    Abidi, S L

    1988-08-05

    Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, A1a, A1b, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins A1, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpreted based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

  16. High-performance liquid-chromatographic separation of subcomponents of antimycin-A

    Science.gov (United States)

    Abidi, S.L.

    1988-01-01

    Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, Ala, Alb, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins Al, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifiers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpretated based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

  17. Feasibility and Validity of a Graded One-Legged Cycle Exercise Test to Determine Peak Aerobic Capacity in Older People With a Lower-Limb Amputation

    NARCIS (Netherlands)

    Wezenberg, Daphne; de Haan, Arnold; van der Woude, Lucas H.; Houdijk, Han

    2012-01-01

    Background. Information concerning exercise tolerance and aerobic capacity is imperative for generating effective and safe exercise programs. However, for older people with a lower-limb amputation, a standard exercise test is not available. Objective. The primary aim of the present study was to dete

  18. Improving the Sensitivity, Resolution, and Peak Capacity of Gradient Elution in Capillary Liquid Chromatography with Large-Volume Injections by Using Temperature-Assisted On-Column Solute Focusing.

    Science.gov (United States)

    Wilson, Rachael E; Groskreutz, Stephen R; Weber, Stephen G

    2016-05-17

    Capillary HPLC (cLC) with gradient elution is the separation method of choice for the fields of proteomics and metabolomics. This is due to the complementary nature of cLC flow rates and electrospray or nanospray ionization mass spectrometry (ESI-MS). The small column diameters result in good mass sensitivity. Good concentration sensitivity is also possible by injection of relatively large volumes of solution and relying on solvent-based solute focusing. However, if the injection volume is too large or solutes are poorly retained during injection, volume overload occurs which leads to altered peak shapes, decreased sensitivity, and lower peak capacity. Solutes that elute early even with the use of a solvent gradient are especially vulnerable to this problem. In this paper, we describe a simple, automated instrumental method, temperature-assisted on-column solute focusing (TASF), that is capable of focusing large volume injections of small molecules and peptides under gradient conditions. By injecting a large sample volume while cooling a short segment of the column inlet at subambient temperatures, solutes are concentrated into narrow bands at the head of the column. Rapidly raising the temperature of this segment of the column leads to separations with less peak broadening in comparison to solvent focusing alone. For large volume injections of both mixtures of small molecules and a bovine serum albumin tryptic digest, TASF improved the peak shape and resolution in chromatograms. TASF showed the most dramatic improvements with shallow gradients, which is particularly useful for biological applications. Results demonstrate the ability of TASF with gradient elution to improve the sensitivity, resolution, and peak capacity of volume overloaded samples beyond gradient compression alone. Additionally, we have developed and validated a double extrapolation method for predicting retention factors at extremes of temperature and mobile phase composition. Using this method

  19. Chemical Compositions, Chromatographic Fingerprints and Antioxidant Activities of Andrographis Herba

    Directory of Open Access Journals (Sweden)

    Yang Zhao

    2014-11-01

    Full Text Available This paper describes the development of an HPLC-UV-MS method for quantitative determination of andrographolide and dehydroandrographolide in Andrographis Herba and establishment of its chromatographic fingerprint. The method was validated for linearity, limit of detection and quantification, inter- and intra-day precisions, repeatability, stability and recovery. All the validation results of quantitative determination and fingerprinting methods were satisfactory. The developed method was then applied to assay the contents of andrographolide and dehydroandrographolide and to acquire the fingerprints of all the collected Andrographis Herba samples. Furthermore, similarity analysis and principal component analysis were used to reveal the similarities and differences between the samples on the basis of the characteristic peaks. More importantly, the DPPH free radical-scavenging and ferric reducing capacities of the Andrographis Herba samples were assayed. By bivariate correlation analysis, we found that six compounds are positively correlated to DPPH free radical scavenging and ferric reducing capacities, and four compounds are negatively correlated to DPPH free radical scavenging and ferric reducing capacities.

  20. Conceptual Design of Hydrogen Isotopes Chromatographic Separation System With Super Large Capacity%超大容量氢同位素色谱分离系统的概念设计

    Institute of Scientific and Technical Information of China (English)

    谢波; 翁葵平; 刘云怒; 侯建平

    2012-01-01

    A super largecapacity hydrogen isotopes separation system, including total plan, unit (including making and purification of gas, three-grade chromatographic columns, gas loop and auto-controll, and carrier recovery) and experimental scheme, had been designed on the basis of a series of hydrogen-deuterium experiments by temperature programmed de-sorption. The characteristic of the system was that desorption kinetic parameters could be directly calculated from the hydrogen isotope separation desorption spectra information. In other words, the complicated dynamic process of separation could be described by the desorption rate equation, shape parameter and desorption activation energy calculation on the condition of the experimental data and appropriate assumptions (equilibrium and adsorption, uniform surface). In previous work, an experimental series of operation to verify the successive enrichment of D2 from a H2-D2 mixture, the production of the deuterium from natural hydrogen and the recovery of tritium such as from the nuclear heavy-water were car-ried out using MS5A at 77 K. This work was only conceptual design, so it was necessary to identify the availability of super large capacity system by experiment.%在多年从事色谱分离氢同位素技术研究的基础上,设计了一套超大容量氢同位素分离系统,包括系统的总体设计,以配气及纯化、三级色谱柱、气体流路及自动控制和载气回收为主的单元设计,以及调试实验方案设计.该系统的特点是可以根据氢同位素分离解吸谱图的信息比较直接地计算出解吸过程的动力学参数,即在实验数据的支持和适当的假设条件(平衡再吸附、均匀表面)下,依靠解吸速率方程、形状参数和解吸活化能的计算便可比较系统地描述其复杂的动力学过程.在以前的工作中,虽然已经证实了采用5A分子筛柱在77 K的低温下,可以连续富集氢-氘混合气中的氘、天然氢中的氘,甚至含

  1. Chromatographic and Related Reactors.

    Science.gov (United States)

    1988-01-07

    special information about effects of surface heteroge- neity in the methanation reaction. Studies of an efficient multicolumn assembly for measuring...of organic basic catalysts such as pyridine and 4-methylpicoline. It was demonstrated that the chromatographic reactor gave special information about...Programmed Reaction to obtain special information about surface heterogeneity in the methanation reaction. Advantages of stopped flow over steady state

  2. Chromatographic analysis of olopatadine in hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Maksić, Jelena; Jovanović, Marko; Rakić, Tijana; Popović, Igor; Ivanović, Darko; Jančić-Stojanović, Biljana

    2015-01-01

    In this paper, chromatographic analysis of active substance olopatadine hydrochloride, which is used in eye drops as antihistaminic agent, and its impurity E isomer by hydrophilic interaction liquid chromatography (HILIC) and application of design of experiments (DoE) methodology are presented. In addition, benzalkonium chloride is very often used as a preservative in eye drops. Therefore, the evaluation of its chromatographic behavior in HILIC was carried out as well. In order to estimate chromatographic behavior and set optimal chromatographic conditions, DoE methodology was applied. After the selection of important chromatographic factors, Box-Behnken design was utilized, and on the basis of the obtained models factor effects were examined. Then, multi-objective robust optimization is performed aiming to obtain chromatographic conditions that comply with several quality criteria simultaneously: adequate and robust separation of critical peak pair and maximum retention of the first eluting peak. The optimal conditions are identified by using grid point search methodology. The experimental verification confirmed the adequacy of the defined optimal conditions. Finally, under optimal chromatographic conditions, the method was validated and applicability of the proposed method was confirmed.

  3. Chromatographic fingerprint analysis of Pycnogenol dietary supplements.

    Science.gov (United States)

    Chen, Pei; Song, Fenhong; Lin, Long-Ze

    2009-01-01

    The bark of maritime pine (Pinus pinaster Aiton) has been widely used as a remedy for various degenerative diseases. A standard high-performance liquid chromatographic (HPLC) procedure for Pycnogenol analysis is a method specified in the United States Pharmacopeia (USP) monograph, which requires measurement of peak areas and identification of four components of the extract: caffeic acid, catechin, ferulic acid, and taxifolin. In this study, a fingerprint analysis using an HPLC method based on the USP monograph has been developed to provide additional qualitative information for the analysis of Pycnogenol-containing dietary supplements (PDS). Twelve commercially available PDS samples were purchased and analyzed along with a standard Pycnogenol extract. Their chromatographic fingerprints were analyzed using principal component analysis. The results showed that two of the samples were not consistent with the standard reference Pycnogenol extract. One contained other active ingredients in addition to Pycnogenol, and the other may have resulted from a quality control issue in manufacturing.

  4. 峰谷电价下配电网中分布式储能的容量配置%Capacity Configuration of Distribution Energy Storage in Distribution Network Under the Peak-valley Price

    Institute of Scientific and Technical Information of China (English)

    杨江涛; 孙春顺; 杨安; 刘佳

    2016-01-01

    为了进一步提高电力系统的可靠性和经济性,对配电网中储能设备的容量进行合理配置。基于分布式储能装置的引入给配电系统带来的影响,并考虑峰谷电价政策的影响,针对储能装置带来的经济效益分别从发电侧、输配电过程、降低网损、峰谷电价效益等各方面进行了经济性上的量化;结合储能装置的自身成本,以年收益最大为目标建立了储能装置容量的优化配置模型。最后考虑储能装置给系统潮流带来的影响,在约束条件中加入节点电压波动约束,通过对算例进行分析,得到了不同类型储能设备的最优容量配置。%In order to improve the reliability and economy of power system further, the capacity of energy storage device should be allocated with ration in the power distribution network. This paper analyzes the effect of the energy storage device on the power distribution system. On this basis, taking the influence of the peak valley price policy on the system into consideration, the benefits of the energy storage device to the system are analyzed, from the as-pects of the power generation, transmission and distribution process, network loss reduce, peak valley price benefit and so on, and are quantified on the side of economy. Combined with the costs of the energy storage device, with the goal of maximizing the revenue, an optimal allocation model of energy storage device capacity is established. Finally, considering the effects of energy storage device to the system trend and adding node voltage fluctuation in constraint conditions, the optimal capacity configurations of different types of energy storage devices are obtained by the analysis of the proposed example.

  5. Optimization of Energy Storage System Capacity for Relaxing Peak Load Regulation Bottlenecks%用于松弛调峰瓶颈的储能系统容量配置方法

    Institute of Scientific and Technical Information of China (English)

    严干贵; 冯晓东; 李军徽; 穆钢; 谢国强; 董效辰; 王芝茗; 杨凯

    2012-01-01

    利用大规模电池储能系统对电网负荷“削峰填谷”,减少日负荷波动幅度,可以缓解发电机组对负荷追踪调控负担,使电网具备更多向下调节容量来接纳风电.基于给定的负荷特性,分析储能系统配置容量与其改善负荷波动水平之间的关系,以储能系统投资成本、经济效益为约束,以综合效益最大为目标,提出一种用于松弛调峰瓶颈的大规模储能系统容量优化配置方法.针对2010年某省电网接纳风电受限现状,利用该方法对其进行改善,分析了储能系统运行年限、投资成本对其容量配置的影响,算例结果验证了所提出方法的可行性.%Using large-scale battery energy storage systems for load shifting and peak smoothing can decrease the fluctuation of daily load and reduce load tracking regulation burden of generator units, and enlarge down-regulate space to accommodate wind power. Based on a given load characteristics, the relationship between the energy storage system allocation capacity and improvement of load fluctuations was analyzed. By making energy storage system's investment costs and economic benefits as constraints, and by maximizing the comprehensive benefits as the object, an optimal capacity-allocation method was proposed for large-scale energy storage systems to relax peak-regulation bottleneck. For the limitation of wind power accommodation of a province in China in 2010, the method was applied to improve the situation and the impact of the life cycle and investment cost of the energy storage system on its capacity configuration. Case study results verified the feasibility of the proposed method.

  6. Ion-exchange chromatographic analysis of peroxynitric acid.

    Science.gov (United States)

    Nakashima, Yoichi; Ikawa, Satoshi; Tani, Atsushi; Kitano, Katsuhisa

    2016-01-29

    Ion-exchange chromatographic analysis of peroxynitric acid (O2NOOH) was performed by combining an acidic eluate with an UV-vis detector and immersing the separation column in an ice-water bath. The decomposition behavior of peroxynitric acid in the solution was also studied using this system. The fraction for the peroxynitric acid peak was collected. Ion-exchange chromatographic analysis of this fraction, after standing at room temperature for 24h, showed that the decomposition products were mainly nitrate ions with a very small amount of nitrous acid. The peroxynitric acid peak area correlated perfectly with the total amount of decomposition products. The ion-exchange chromatographic isolation allowed us to evaluate the molar extinction coefficient of peroxynitric acid precisely in a wider wavelength range than previous reports. The value decreases monotonically from 1729±26M(-1)cm(-1) at 200nm to 12.0±0.5M(-1)cm(-1) at 290nm.

  7. Chromatographic separation and concentration of quercetin and (+)-catechin using mesoporous composites based on MCM-41

    Science.gov (United States)

    Karpov, S. I.; Belanova, N. A.; Korabel'nikova, E. O.; Nedosekina, I. V.; Roessner, F.; Selemenev, V. F.

    2015-05-01

    Data on chromatographic separation of quercetin and (+)-catechin-flavonoids with similar physicochemical (including sorption) properties—are presented. The highest efficiency of chromatographic process at high sorption capacity of the material with respect to quercetin and slightly lower capacity for (+)-catechin were observed when silylated composites of ordered MCM-41 type materials were used. The application of acetonitrile as a solvent increased the sorption capacity of the material and can be recommended for separation of related polyphenol substances and their determination using ordered MCM-41 modified with trimethylchlorosilane as a stationary phase in a chromatographic column.

  8. Chromatographic fingerprints analysis for evaluation of Ginkgo Biloba products

    Science.gov (United States)

    The leaf extract of Ginkgo biloba has purported value for improving mental capacities in Alzheimer’s patients. The flavonoids and the terpene lactones are considered to be the two main active components that influence human health. This paper compared an LC/UV chromatographic fingerprint method wi...

  9. Headspace chromatographic determination of water pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Otson, R.; Williams, D.T.

    1982-05-01

    A readily constructed, automated purging assembly, on-column trapping, and simultaneous use of flame ionization and electrolytic conductivity detectors were applied to develop a dynamic headspace gas chromatographic technique which was evaluated for the determination of 42 organic polluants in water. Detection limits of <1 ..mu..g/L and linear plots of peak area against concentration in the range 0.25-16 ..mu..g/L were obtained for 32 compounds. At aqueous concentrations of 4 and 16 ..mu..g/L, peak area precision of <10% relative standard deviation (RSD) for triplicate sample analysis and purging efficiencies of >75% were generally obtained. Storage of aqueous composite standard solutions at 4 and 16 ..mu..g/L for 6 weeks at 4/sup 0/C did not usually affect analytical results by more than +/- 15%.

  10. Chromatographic separation of alkaline phosphatase from dental enamel

    DEFF Research Database (Denmark)

    Moe, D; Kirkeby, S; Salling, E

    1989-01-01

    Alkaline phosphatase (AP) was prepared from partly mineralized bovine enamel by extraction in phosphate buffer, centrifugation and various chromatographic techniques. Chromatofocusing showed that the enamel enzyme possessed five isoelectric points at the acid pH level ranging from pH 5.7 to pH 4.......4. Three enzyme peaks were eluted using low pressure chromatography with a Bio-gel column. With a HPLC gel filtration column the separation of the enamel extract resulted in only one peak with AP activity. The fractions of this peak were used to produce an antibody against bovine AP....

  11. Peak Oil, Peak Coal and Climate Change

    Science.gov (United States)

    Murray, J. W.

    2009-05-01

    Research on future climate change is driven by the family of scenarios developed for the IPCC assessment reports. These scenarios create projections of future energy demand using different story lines consisting of government policies, population projections, and economic models. None of these scenarios consider resources to be limiting. In many of these scenarios oil production is still increasing to 2100. Resource limitation (in a geological sense) is a real possibility that needs more serious consideration. The concept of 'Peak Oil' has been discussed since M. King Hubbert proposed in 1956 that US oil production would peak in 1970. His prediction was accurate. This concept is about production rate not reserves. For many oil producing countries (and all OPEC countries) reserves are closely guarded state secrets and appear to be overstated. Claims that the reserves are 'proven' cannot be independently verified. Hubbert's Linearization Model can be used to predict when half the ultimate oil will be produced and what the ultimate total cumulative production (Qt) will be. US oil production can be used as an example. This conceptual model shows that 90% of the ultimate US oil production (Qt = 225 billion barrels) will have occurred by 2011. This approach can then be used to suggest that total global production will be about 2200 billion barrels and that the half way point will be reached by about 2010. This amount is about 5 to 7 times less than assumed by the IPCC scenarios. The decline of Non-OPEC oil production appears to have started in 2004. Of the OPEC countries, only Saudi Arabia may have spare capacity, but even that is uncertain, because of lack of data transparency. The concept of 'Peak Coal' is more controversial, but even the US National Academy Report in 2007 concluded only a small fraction of previously estimated reserves in the US are actually minable reserves and that US reserves should be reassessed using modern methods. British coal production can be

  12. Considerations on the temperature dependence of the gas-liquid chromatographic retention.

    Science.gov (United States)

    González, Francisco Rex

    2002-01-04

    A discussion on the temperature dependence of the partition coefficient K is developed. This discussion embraces topics such as the limitations of conventional thermodynamic approaches followed in the chromatographic literature, qualitative theoretical notions arising from molecular thermodynamics and the experimental information that is accessible through modern capillary gas chromatography. It is shown that the heat capacity difference of solute transfer for flexible molecules has at least one maximum in the chromatographic range of temperature. As a consequence, a great amount of experimental data is required for a correct thermodynamic interpretation of the chromatographic retention.

  13. Study on chromatographic fingerprint of sarcandra glabra (Thunb.) by microwave-assisted extraction coupled to HPLC/DAD

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Microwave-assisted extraction(MAE)was used for extraction of effective components of sarcandra glabra(Thunb.),and then chromatographic fingerprint of sarcandra glabra(Thunb.)was studied by high performance liquid chromatography/diode array detector(HPLC/DAD).The conditions of MAE were optimized by an orthogonal experiment,and then the authentication and validation of the chromatographic fingerprint were conducted.Nine peaks were identified as common peaks in the fingerprint chromatograms,and isofraxidin was...

  14. PeakWorks

    Energy Technology Data Exchange (ETDEWEB)

    2016-11-30

    The PeakWorks software is designed to assist in the quantitative analysis of atom probe tomography (APT) generated mass spectra. Specifically, through an interactive user interface, mass peaks can be identified automatically (defined by a threshold) and/or identified manually. The software then provides a means to assign specific elemental isotopes (including more than one) to each peak. The software also provides a means for the user to choose background subtraction of each peak based on background fitting functions, the choice of which is left to the users discretion. Peak ranging (the mass range over which peaks are integrated) is also automated allowing the user to chose a quantitative range (e.g. full-widthhalf- maximum). The software then integrates all identified peaks, providing a background-subtracted composition, which also includes the deconvolution of peaks (i.e. those peaks that happen to have overlapping isotopic masses). The software is also able to output a 'range file' that can be used in other software packages, such as within IVAS. A range file lists the peak identities, the mass range of each identified peak, and a color code for the peak. The software is also able to generate 'dummy' peak ranges within an outputted range file that can be used within IVAS to provide a means for background subtracted proximity histogram analysis.

  15. Paniek over Peak Food

    NARCIS (Netherlands)

    Koning, N.B.J.

    2015-01-01

    Het kon niet uitblijven. De groei van de voedselproductie stagneert en na Peak Oil dreigt nu Peak Food. Onzin, vindt Niek Koning, die zogenaamde peak is een van de toppen in een langjarige golfbeweging op de landbouwmarkten. Toch zijn er genoeg redenen om je zorgen te maken over de wereldvoedselvoor

  16. Are Bragg Peaks Gaussian?

    Science.gov (United States)

    Hammouda, Boualem

    2014-01-01

    It is common practice to assume that Bragg scattering peaks have Gaussian shape. The Gaussian shape function is used to perform most instrumental smearing corrections. Using Monte Carlo ray tracing simulation, the resolution of a realistic small-angle neutron scattering (SANS) instrument is generated reliably. Including a single-crystal sample with large d-spacing, Bragg peaks are produced. Bragg peaks contain contributions from the resolution function and from spread in the sample structure. Results show that Bragg peaks are Gaussian in the resolution-limited condition (with negligible sample spread) while this is not the case when spread in the sample structure is non-negligible. When sample spread contributes, the exponentially modified Gaussian function is a better account of the Bragg peak shape. This function is characterized by a non-zero third moment (skewness) which makes Bragg peaks asymmetric for broad neutron wavelength spreads. PMID:26601025

  17. Vibrational Spectroscopy of Chromatographic Interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Jeanne E. Pemberton

    2011-03-10

    Chromatographic separations play a central role in DOE-supported fundamental research related to energy, biological systems, the environment, and nuclear science. The overall portfolio of research activities in the Separations and Analysis Program within the DOE Office of Basic Energy Sciences includes support for activities designed to develop a molecular-level understanding of the chemical processes that underlie separations for both large-scale and analytical-scale purposes. The research effort funded by this grant award was a continuation of DOE-supported research to develop vibrational spectroscopic methods to characterize the interfacial details of separations processes at a molecular level.

  18. A gas chromatograph/mass spectrometry method for determining isotopic distributions in organic compounds used in the chemical approach to stable isotope separation

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, A.M.; Spall, W.D.; Smith, B.F.

    1990-01-01

    A variety of gas chromatograph/mass spectrometry (GC/MS) methods have been developed to resolve benzene, benzophenone, anthracene, fluorenone, and their respective stable isotope analogs from other components by gas chromatography. The ratio of stable isotope-labeled material to natural isotopic abundance compounds is determined from the mass spectra averaged across the chromatographic peak. Both total ion and selective ion chromatographic approaches were used for relative data and comparison. 9 refs., 11 tabs.

  19. Liquid Chromatographic Method for Determination of Nisoldipine from Pharmaceutical Samples

    Directory of Open Access Journals (Sweden)

    Amit Gupta

    2010-01-01

    Full Text Available A simple and specific high performance thin layer chromatographic method was developed and validated for the determination of nisoldipine from tablet dosage form. The method was carried out at 320 nm after extraction of drug in methanol. The method uses aluminum plates pre-coated with silica gel 60F-254 as stationary phase and cyclohexane-ethyl acetate-toluene (3:3:4, v/v/v as mobile phase. Linearity was established over a range of 400-2400 ng per zone. Both peak area ratio and peak height ratio showed acceptable correlation coefficient i.e. more than 0.99. However we used peak area for validation purpose. Intra-day and inter-day precision was determined and found to have less than 6.0 % RSD.

  20. Peak Experience Project

    Science.gov (United States)

    Scott, Daniel G.; Evans, Jessica

    2010-01-01

    This paper emerges from the continued analysis of data collected in a series of international studies concerning Childhood Peak Experiences (CPEs) based on developments in understanding peak experiences in Maslow's hierarchy of needs initiated by Dr Edward Hoffman. Bridging from the series of studies, Canadian researchers explore collected…

  1. Peak Experience Project

    Science.gov (United States)

    Scott, Daniel G.; Evans, Jessica

    2010-01-01

    This paper emerges from the continued analysis of data collected in a series of international studies concerning Childhood Peak Experiences (CPEs) based on developments in understanding peak experiences in Maslow's hierarchy of needs initiated by Dr Edward Hoffman. Bridging from the series of studies, Canadian researchers explore collected…

  2. Chromatographic background drift correction coupled with parallel factor analysis to resolve coelution problems in three-dimensional chromatographic data: quantification of eleven antibiotics in tap water samples by high-performance liquid chromatography coupled with a diode array detector.

    Science.gov (United States)

    Yu, Yong-Jie; Wu, Hai-Long; Fu, Hai-Yan; Zhao, Juan; Li, Yuan-Na; Li, Shu-Fang; Kang, Chao; Yu, Ru-Qin

    2013-08-01

    Chromatographic background drift correction has been an important field of research in chromatographic analysis. In the present work, orthogonal spectral space projection for background drift correction of three-dimensional chromatographic data was described in detail and combined with parallel factor analysis (PARAFAC) to resolve overlapped chromatographic peaks and obtain the second-order advantage. This strategy was verified by simulated chromatographic data and afforded significant improvement in quantitative results. Finally, this strategy was successfully utilized to quantify eleven antibiotics in tap water samples. Compared with the traditional methodology of introducing excessive factors for the PARAFAC model to eliminate the effect of background drift, clear improvement in the quantitative performance of PARAFAC was observed after background drift correction by orthogonal spectral space projection.

  3. The central peak revisited

    Energy Technology Data Exchange (ETDEWEB)

    Shirane, G.

    1995-10-27

    The central peak in SrTiO{sub 3} was first observed by Riste and his collaborators in 1971. This was one of the key discoveries leading to an understanding of the dynamics of phase transitions. The most recent discovery of two length scales in SrTiO{sub 3} motivated a reinvestigation of the soft phonon and associated central peak by neutron scattering. These recent experiments shed new light on the nature of the central peak. It is now well established to be strongly sample dependent and it originates from defects in bulk crystals.

  4. Pikes Peak, Colorado

    Science.gov (United States)

    Brunstein, Craig; Quesenberry, Carol; Davis, John; Jackson, Gene; Scott, Glenn R.; D'Erchia, Terry D.; Swibas, Ed; Carter, Lorna; McKinney, Kevin; Cole, Jim

    2006-01-01

    For 200 years, Pikes Peak has been a symbol of America's Western Frontier--a beacon that drew prospectors during the great 1859-60 Gold Rush to the 'Pikes Peak country,' the scenic destination for hundreds of thousands of visitors each year, and an enduring source of pride for cities in the region, the State of Colorado, and the Nation. November 2006 marks the 200th anniversary of the Zebulon M. Pike expedition's first sighting of what has become one of the world's most famous mountains--Pikes Peak. In the decades following that sighting, Pikes Peak became symbolic of America's Western Frontier, embodying the spirit of Native Americans, early explorers, trappers, and traders who traversed the vast uncharted wilderness of the Western Great Plains and the Southern Rocky Mountains. High-quality printed paper copies of this poster are available at no cost from Information Services, U.S. Geological Survey (1-888-ASK-USGS).

  5. Peak of Achievement

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    China’s first inland research station on the highest peak of Antarctic progresses smoothly China will complete the construction of its first inland Antarctic research station at Dome A,the highest polar icecap peak at 4,093 meters above sea level,next year,according to a south pole scientist involved in the project. "The preparatory work for the new sta-

  6. 肥胖对心肌梗死后患者峰值有氧工作能力的影响%The influence of adiposity on peak aerobic capacity in post myocardial infarction patients

    Institute of Scientific and Technical Information of China (English)

    刘洵; Brodie DA; 周凤; 冯晟; 陈彦平; 刘静; 梁晓琳; 李承蒙; Bundred PE

    2011-01-01

    检测肥胖对心肌梗死后(PMI)患者心脏康复早期有氧工作能力的影响.方法:116例男性PMI患者根据其身体质量指数(BMI)高于或低于25和服用或未服用β-阻断剂被分为4组,然后进行递增负荷运动实验,其间记录每级负荷时的摄氧量(VO2)、心率(HR)、血压和自我用力感觉(RPE),并持续监测12导联心电图(ECG).结果:BMI< 25的两组患者都能坚持较长时间的运动(P< 0.05),有较高的峰值摄氧量(P<0.05)和较低的有氧能力的损伤(P< 0.01).当RPE到达13时,其他组别的V02分别是BMI< 25且服用β-阻断剂组的90%(未服用β-阻断剂,BMI< 25),75%(服用β-阻断剂,BMI> 25)和70%(未服用β-阻断剂,BMI> 25).结论:肥胖会影响患者运动中的功能和代谢能力,但服用β-阻断剂对此可有所补偿.BMI< 25对于减轻氧能力损伤将会有明显的益处.%Objective: To examine the influence of adiposity on the aerobic capacity of post myocardial infarction (PMI) patients during early stage of cardiac rehabilitation.Method: One hundred and sixteen male recent PMI patients were divided into four groups according to their body mass index (BMI) above or below 25, and with or without taking β -blocker. Then, a graded exercise test was performed; oxygen uptake (VO2), heart rate (HR), blood pressure and ratings of perceived exertion (RPE) were recorded, and 12 lead electrocardiogram (ECG) was monitored continuously.Result: Both groups with BMI25) and 70% (no β -blocker, BMI>25) respectively.Conclusion: Adiposity can compromise patients' function and metabolic capacity during exercise, but in patients taking β -blocker there may be some compensation. One with BMI <25 will have particular benefits for alleviating functional aerobic impairment.Author's address Department of Human Movement Science, Tianjin University of Sport, Tianjin, 300381

  7. Chromatographic zinc isotope separation by phenol formaldehyde benzo crown resin.

    Science.gov (United States)

    Ding, Xingcheng; Nomura, Masao; Suzuki, Tatsuya; Sugiyama, Yuichi; Kaneshiki, Toshitaka; Fujii, Yasuhiko

    2006-04-28

    New types of phenol formaldehyde resin having benzo crown as a functional group were synthesized and applied to zinc isotope chromatographic operation. Zinc adsorption and isotope separation capacities were dramatically improved by using phenol formaldehyde benzo-15-crown-5 resin. Zinc batch adsorption tests were performed by various dehydrated organic solvents. Separation coefficient, epsilon 8.1 x 10(-4) and height equivalent to a theoretical plate (HETP) 0.105 cm for the isotopic pair of 68Zn/64Zn in phenol formaldehyde benzo-15-crown-5 resin were obtained in the case of acetone as the solvent at 298+/-1K.

  8. Age-graded reductions in quadriceps muscle strength and peak aerobic capacity in COPD Reduções graduadas por idade na força muscular do quadríceps e no pico de consumo de oxigênio na DPOC

    Directory of Open Access Journals (Sweden)

    Martijn A. Spruit

    2012-04-01

    Full Text Available BACKGROUND: Reductions in quadriceps strength and peak aerobic capacity (VO2 in patients with chronic obstructive pulmonary disease (COPD have been studied in relatively small samples over a short period. Moreover, results were not corrected for confounding variables, such as lean muscle mass, gender, and gas transfer capacity of the lungs. OBJECTIVES: To compare quadriceps muscle strength and peak V.O2 in women and men while stratifying for age and gas transfer capacity. We then corrected for lower-limb lean muscle mass to see whether and to what extent the age-graded reduction remained evident. METHODS: Retrospectively, data of 374 women and 593 men with COPD were analyzed: lung function, current drug therapy, quadriceps strength, peak V.O2, lower-limb lean muscle mass, and gas transfer capacity. RESULTS: Quadriceps strength and peak V.O2 were lower in older women and men with a gas transfer capacity of 50% predicted. Yet, counter to our hypothesis, lower-limb lean muscle mass did not show an age-graded reduction and, in turn, could not account for the relationship of age with quadriceps strength and peak V.O2. CONCLUSIONS: It is apparent that there is an age-graded reduction in skeletal muscle function in patients with COPD. Therefore, prevention of an age-graded decline in quadriceps muscle strength and peak V.O2 may need to become an outcome of pulmonary rehabilitation of patients with COPD.CONTEXTUALIZAÇÃO: As reduções da força do quadríceps e do pico de consumo de oxigênio (V.O2 em pacientes com doença pulmonar obstrutiva crônica (DPOC são estudadas em amostras relativamente pequenas e por curto período de tempo. Além disso, os resultados não são corrigidos por variáveis confundidoras, como conteúdo de massa magra, gênero e capacidade de difusão pulmonar. OBJETIVOS: Comparar a força muscular do quadríceps e o pico de V.O2 em mulheres e homens estratificados por idade e capacidade de difusão pulmonar e, ent

  9. Reverse-phase high pressure liquid chromatographic analysis of harpagoside, scorodioside and verbascoside from Scrophularia scorodonia: quantitative determination of harpagoside.

    Science.gov (United States)

    Díaz, A; Fernández, L; Ollivier, E; Martín, T; Villaescusa, L; Balansard, G

    1998-02-01

    A reversed-phase high performance liquid chromatographic method has been developed for the determination of the main compounds (harpagoside, scorodioside, and verbascoside) from different samples of Scrophularia scorodonia. The chromatographic method has been validated and applied for quantitative determination of harpagoside. The results show the highest levels of harpagoside in the leaf extract. The purity and identity of peaks were controlled by diode-array detection and comparison with standards.

  10. Correlation-Peak Imaging

    Science.gov (United States)

    Ziegler, A.; Metzler, A.; Köckenberger, W.; Izquierdo, M.; Komor, E.; Haase, A.; Décorps, M.; von Kienlin, M.

    1996-08-01

    Identification and quantitation in conventional1H spectroscopic imagingin vivois often hampered by the small chemical-shift range. To improve the spectral resolution of spectroscopic imaging, homonuclear two-dimensional correlation spectroscopy has been combined with phase encoding of the spatial dimensions. From the theoretical description of the coherence-transfer signal in the Fourier-transform domain, a comprehensive acquisition and processing strategy is presented that includes optimization of the width and the position of the acquisition windows, matched filtering of the signal envelope, and graphical presentation of the cross peak of interest. The procedure has been applied to image the spatial distribution of the correlation peaks from specific spin systems in the hypocotyl of castor bean (Ricinus communis) seedlings. Despite the overlap of many resonances, correlation-peak imaging made it possible to observe a number of proton resonances, such as those of sucrose, β-glucose, glutamine/glutamate, lysine, and arginine.

  11. Utilization of a diol-stationary phase column in ion chromatographic separation of inorganic anions.

    Science.gov (United States)

    Arai, Kaori; Mori, Masanobu; Kozaki, Daisuke; Nakatani, Nobutake; Itabashi, Hideyuki; Tanaka, Kazuhiko

    2012-12-28

    We describe the ion chromatographic separation of inorganic anions using a diol-stationary phase column (-CH(OH)CH(2)OH; diol-column) without charged functional groups. Anions were separated using acidic eluent as in typical anion-exchange chromatography. The retention volumes of anions on the diol-column increased with increasing H(+) concentration in the eluent. The anion-exchange capacities of diol-columns in the acidic eluent (pH 2.8) were larger than that of zwitterionic stationary phase column but smaller than that of an anion-exchange column. The separation of anions using the diol-column was strongly affected by the interaction of H(+) ions with the diol-functional groups and by the types of the eluents. In particular, the selection of the eluent was very important for controlling the retention time and resolution. Good separation was obtained using a diol-column (HILIC-10) with 5 mM phthalic acid as eluent. The limits of detection at a signal-to-noise ratio of 3 ranged from 1.2 to 2.7 μM with relative standard deviations (RSD, n=5) of 0.04-0.07% for the retention time and 0.4-2.0% for the peak areas. This method was successfully applied to the determination of H(2)PO(4)(-), Cl(-), and NO(3)(-) in a liquid fertilizer sample.

  12. Chromatographic separation of fructose from date syrup.

    Science.gov (United States)

    Al Eid, Salah M

    2006-01-01

    The objective of this study is to provide a process for separating fructose from a mixture of sugars containing essentially fructose and glucose, obtained from date palm fruits. The extraction procedure of date syrup from fresh dates gave a yield of 86.5% solids after vacuum drying. A process for separating fructose from an aqueous solution of date syrup involved adding the date syrup solutions (20, 30 and 40% by weight) to a chromatographic column filled with Dowex polystyrene strong cation exchange gel matrix resin Ca2 + and divinylbenzene, a functional group, sulfonic acid, particle size 320 microm, with a flow rate of 0.025 and 0.05 bed volume/min, under 30 and 70 degrees C column temperature. After the date sugar solution batch, a calculated quantity of water was added to the column. Glucose was retained by the resin more weakly than fructose and proceeded faster into the water batch flowing ahead. Three fractions were collected: a glucose-rich fraction, a return fraction, and a fructose-rich fraction. The return fraction is based on when the peaks of fructose and glucose were reached, which could be determined by means of an analyzer (polarimeter) based on the property of glucose and fructose solutions to turn the polarization level of polarized light. A high yield of fructose is obtained at 70 degrees C column temperature with a flow rate of 0.025 bed volume/min and date syrup solution containing 40% sugar concentration. The low recovery by weight obtained using date syrup solutions having a sugar concentration of 20 and 30%, encourages the use of a concentration of 40%. However, with the 40% date syrup supply the average concentrations of glucose and fructose in the return fractions were more than 40%, which can be used for diluting the thick date syrup solution extracted from dates.

  13. Peak-interviewet

    DEFF Research Database (Denmark)

    Raalskov, Jesper; Warming-Rasmussen, Bent

    Peak-interviewet er en særlig effektiv metode til at gøre ubevidste menneskelige ressourcer bevidste. Fokuspersonen (den interviewede) interviewes om en selvvalgt, personlig succesoplevelse. Terapeuten/coachen (intervieweren) spørger ind til processen, som ledte hen til denne succes. Herved afdæk...

  14. Peak-interviewet

    DEFF Research Database (Denmark)

    Raalskov, Jesper; Warming-Rasmussen, Bent

    Peak-interviewet er en særlig effektiv metode til at gøre ubevidste menneskelige ressourcer bevidste. Fokuspersonen (den interviewede) interviewes om en selvvalgt, personlig succesoplevelse. Terapeuten/coachen (intervieweren) spørger ind til processen, som ledte hen til denne succes. Herved afdæk...

  15. Impact Crater with Peak

    Science.gov (United States)

    2002-01-01

    (Released 14 June 2002) The Science This THEMIS visible image shows a classic example of a martian impact crater with a central peak. Central peaks are common in large, fresh craters on both Mars and the Moon. This peak formed during the extremely high-energy impact cratering event. In many martian craters the central peak has been either eroded or buried by later sedimentary processes, so the presence of a peak in this crater indicates that the crater is relatively young and has experienced little degradation. Observations of large craters on the Earth and the Moon, as well as computer modeling of the impact process, show that the central peak contains material brought from deep beneath the surface. The material exposed in these peaks will provide an excellent opportunity to study the composition of the martian interior using THEMIS multi-spectral infrared observations. The ejecta material around the crater can is well preserved, again indicating relatively little modification of this landform since its initial creation. The inner walls of this approximately 18 km diameter crater show complex slumping that likely occurred during the impact event. Since that time there has been some downslope movement of material to form the small chutes and gullies that can be seen on the inner crater wall. Small (50-100 m) mega-ripples composed of mobile material can be seen on the floor of the crater. Much of this material may have come from the walls of the crater itself, or may have been blown into the crater by the wind. The Story When a meteor smacked into the surface of Mars with extremely high energy, pow! Not only did it punch an 11-mile-wide crater in the smoother terrain, it created a central peak in the middle of the crater. This peak forms kind of on the 'rebound.' You can see this same effect if you drop a single drop of milk into a glass of milk. With craters, in the heat and fury of the impact, some of the land material can even liquefy. Central peaks like the one

  16. On the trail of double peak hydrographs

    Science.gov (United States)

    Martínez-Carreras, Núria; Hissler, Christophe; Gourdol, Laurent; Klaus, Julian; Juilleret, Jérôme; François Iffly, Jean; McDonnell, Jeffrey J.; Pfister, Laurent

    2016-04-01

    and the plateau) equally contribute to the generation of delayed peaks in double peak hydrographs. We found evidence of catchment storage being a dominant control on the delayed peak activation. The amount of this storage threshold was consistent over a 3-year period. Hillslopes were connected to the stream at low discharge values, whereas the plateau contribution to discharge was significant when storage reached a certain threshold value. The latter seems to trigger the generation of the delayed peak in the double peak events. We also observed a non-linear relationship between storage and discharge, which leads to hysteretic relationships between both variables. During single peak hydrographs and first peaks in double peak hydrographs discharge increases faster and peaks before catchment storage, resulting in counter-clockwise hysteretic loops. This was explained by the fact that these runoff peaks are generated by precipitation falling directly into the stream or near stream locations, and/or by the contribution of water flowing through preferential flowpaths that quickly reached the stream network. When catchment storage exceeded the threshold for the generation of double peak hydrographs, events showed clockwise hysteretic loops. It is the stored water in the catchment that will peak first and consequently generate the delayed peak in the hydrograph as a result of the capacity exceedance of a subsurface storage.

  17. Adsorption behavior of plasmid DNA onto perfusion chromatographic matrix

    Institute of Scientific and Technical Information of China (English)

    Miladys LIMONTA; Lourdes ZUMALACARREGUI; Dayana SOLER

    2012-01-01

    Anion exchange chromatography is the most popular chromatographic method for plasmid separa-tion.POROS RI 50 is a perfusion chromatographic support which is a reversed phase matrix and is an alterna-tive to conventional ones due to its mass transfer properties.The adsorption and elution of the pIDKE2 plasmidonto reversed phase POROS RI 50 was studied.Langmuir isotherm model was adjusted in order to get the max-imum adsorption capacity and the dissociation constant for POROS RI 50-plasmid DNA (pDNA) system.Break-through curves were obtained for volumetric flows between 0.69-3.33mL/min,given dynamic capacity up to2.3 times higher than those reported for ionic exchange matrix used during the purification process of plasmidswith similar size to that of pIDKE2.The efficiency was less than 45% for the flow conditions and initial concen-tration studied,which means that the support will not be operated under saturation circumstances.

  18. Peak alignment using wavelet pattern matching and differential evolution.

    Science.gov (United States)

    Zhang, Zhi-Min; Chen, Shan; Liang, Yi-Zeng

    2011-01-30

    Retention time shifts badly impair qualitative or quantitative results of chemometric analyses when entire chromatographic data are used. Hence, chromatograms should be aligned to perform further analysis. Being inspired and motivated by this purpose, a practical and handy peak alignment method (alignDE) is proposed, implemented in this research for one-way chromatograms, which basically consists of five steps: (1) chromatogram lengths equalization using linear interpolation; (2) accurate peak pattern matching by continuous wavelet transform (CWT) with the Mexican Hat and Haar wavelets as its mother wavelets; (3) flexible baseline fitting utilizing penalized least squares; (4) peak clustering when gap of two peaks is smaller than a certain threshold; (5) peak alignment using differential evolution (DE) to maximize linear correlation coefficient between reference signal and signal to be aligned. This method is demonstrated with both simulated chromatograms and real chromatograms, for example, chromatograms of fungal extracts and Red Peony Root obtained by HPLC-DAD. It is implemented in R language and available as open source software to a broad range of chromatograph users (http://code.google.com/p/alignde).

  19. Nanofluidic Size-Exclusion Chromatograph

    Science.gov (United States)

    Feldman, Sabrina; Svehla, Danielle; Grunthaner, Frank; Feldman, Jason; Shakkottai, P.

    2004-01-01

    Efforts are under way to develop a nanofluidic size-exclusion chromatograph (SEC), which would be a compact, robust, lightweight instrument for separating molecules of interest according to their sizes and measuring their relative abundances in small samples. About as large as a deck of playing cards, the nanofluidic SEC would serve, in effect, as a laboratory on a chip that would perform the functions of a much larger, conventional, bench-top SEC and ancillary equipment, while consuming much less power and much smaller quantities of reagent and sample materials. Its compactness and low power demand would render it attractive for field applications in which, typically, it would be used to identify and quantitate a broad range of polar and nonpolar organic compounds in soil, ice, and water samples. Size-exclusion chromatography is a special case of high-performance liquid chromatography. In a conventional SEC, a sample plug is driven by pressure along a column packed with silica or polymer beads that contain uniform nanopores. The interstices between, and the pores in, the beads collectively constitute a size-exclusion network. Molecules follow different paths through the size-exclusion network, such that characteristic elution times can be related to sizes of molecules: basically, smaller molecules reach the downstream end of the column after the larger ones do because the smaller ones enter minor pores and stay there for a while, whereas the larger ones do not enter the pores. The volume accessible to molecules gradually diminishes as their size increases. All molecules bigger than a pore size elute together. For most substances, the elution times and sizes of molecules can be correlated directly with molecular weights. Hence, by measuring the flux of molecules arriving at the downstream end as a function of time, one can obtain a liquid mass spectrum for the molecules present in a sample over a broad range of molecular weights.

  20. Improved stochastic resonance algorithm for enhancement of signal-to-noise ratio of high-performance liquid chromatographic signal

    Energy Technology Data Exchange (ETDEWEB)

    Xie Shaofei [Center for Instrumental Analysis, China Pharmaceutical University, Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Nanjing 210009 (China); Xiang Bingren [Center for Instrumental Analysis, China Pharmaceutical University, Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Nanjing 210009 (China)]. E-mail: cpuxsf@hotmail.com; Deng Haishan [Center for Instrumental Analysis, China Pharmaceutical University, Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Nanjing 210009 (China); Xiang Suyun [Center for Instrumental Analysis, China Pharmaceutical University, Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Nanjing 210009 (China); Lu Jun [Center for Instrumental Analysis, China Pharmaceutical University, Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Nanjing 210009 (China)

    2007-02-28

    Based on the theory of stochastic resonance, an improved stochastic resonance algorithm with a new criterion for optimizing system parameters to enhance signal-to-noise ratio (SNR) of HPLC/UV chromatographic signal for trace analysis was presented in this study. Compared with the conventional criterion in stochastic resonance, the proposed one can ensure satisfactory SNR as well as good peak shape of chromatographic peak in output signal. Application of the criterion to experimental weak signals of HPLC/UV was investigated and the results showed an excellent quantitative relationship between different concentrations and responses.

  1. Nonlinear preprocessing method for detecting peaks from gas chromatograms

    Directory of Open Access Journals (Sweden)

    Min Hyeyoung

    2009-11-01

    Full Text Available Abstract Background The problem of locating valid peaks from data corrupted by noise frequently arises while analyzing experimental data. In various biological and chemical data analysis tasks, peak detection thus constitutes a critical preprocessing step that greatly affects downstream analysis and eventual quality of experiments. Many existing techniques require the users to adjust parameters by trial and error, which is error-prone, time-consuming and often leads to incorrect analysis results. Worse, conventional approaches tend to report an excessive number of false alarms by finding fictitious peaks generated by mere noise. Results We have designed a novel peak detection method that can significantly reduce parameter sensitivity, yet providing excellent peak detection performance and negligible false alarm rates from gas chromatographic data. The key feature of our new algorithm is the successive use of peak enhancement algorithms that are deliberately designed for a gradual improvement of peak detection quality. We tested our approach with real gas chromatograms as well as intentionally contaminated spectra that contain Gaussian or speckle-type noise. Conclusion Our results demonstrate that the proposed method can achieve near perfect peak detection performance while maintaining very small false alarm probabilities in case of gas chromatograms. Given the fact that biological signals appear in the form of peaks in various experimental data and that the propose method can easily be extended to such data, our approach will be a useful and robust tool that can help researchers highlight valid signals in their noisy measurements.

  2. Size exclusion chromatographic analysis of polyphenol-serum albumin complexes.

    Science.gov (United States)

    Hatano, Tsutomu; Hori, Mami; Hemingway, Richard W; Yoshida, Takashi

    2003-08-01

    Formation of water-soluble polyphenol-protein complexes was investigated by size-exclusion chromatography (SEC). The combination of (-)-epigallocatechin gallate (EGCG) and bovine serum albumin (BSA), which did not form a precipitate after the solutions were mixed, showed an SEC peak due to complex formation 2-24 h after mixing. Peak size of the complex varied with time, suggesting slow change of the conformation of the protein accompanied by complexation. Formation of the complex was substantiated by ultrafiltration of the mixture; the complex did not pass through a membrane with a 100,000 nominal molecular weight limit (NMWL). The SEC profile varied with the combination of compounds. The peaks due to the complexes showed that the apparent value of the number average molecular weight (M(n)) of the EGCG-BSA complex was 2.8x10(5), while that of a pentagalloylglucose (PGG)-BSA complex was 9.5x10(5) under the conditions used. Dimeric hydrolyzable tannins, oenothein B and cornusiin A, also caused changes in the SEC profile of BSA, although the combinations did not show peaks attributable to formation of such large complexes observed for EGCG and PGG. Procyanidin B3 and (+)-catechin did not cause changes in the SEC profile of BSA. With cytochrome c, EGCG did not show any chromatographic changes.

  3. Industrial scale chromatographic separation of valuable compounds from biomass hydrolysates and side streams

    Energy Technology Data Exchange (ETDEWEB)

    Saari, P.

    2011-06-15

    Carbohydrates are composed of a number of various monosaccharides, glucose being the most abundant. Some of the monosaccharides are valuable compounds used in the food and pharmaceutical industries. They can be separated from biomass hydrolysates e.g. by chromatographic methods. In this thesis, chromatographic separation of valuable compounds using ion exchange resins was studied on an industrial scale. Of special interest were rare monosaccharides in biomass hydrolysates. A novel chromatographic separation process was developed for fucose, starting from pre-processed spent sulfite liquor. The core of the process consists of three chromatographic separations with different types of ion exchange resins. Chromatographic separation of galactose was tested with three biomass hydrolysates; lactose, gum arabic and hemicellulose hydrolysates. It was demonstrated that also galactose can be separated from complex carbohydrate mixtures. A recovery process for arabinose from citrus pectin liquid residual and for mannose from wood pulp hydrolysate were also developed and experimentally verified. In addition to monosaccharides, chromatographic separation of glycinebetaine from vinasse was examined with a hydrogen form weak acid cation exchange resin. The separation involves untypical peak formation depending, for example, on the pH and the cation composition. The retention mechanism was found to be hydrogen bonding between glycinebetaine and the resin. In the experimental part, all four resin types - strong acid cation, strong base anion, weak acid cation and weak base anion exchange resins - were used. In addition, adsorption equilibria data of seven monosaccharides and sucrose were measured with the resins in sodium and sulfate forms because such data have been lacking. It was found out that the isotherms of all sugars were linear under industrial conditions. A systematic method for conceptual process design and sequencing of chromatographic separation steps were developed

  4. Optimization of Chromatographic Conditions for Detecting Ellagic Acid in Pomegranate Peels Using HPLC Method

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    [Objective] This study aimed to optimize the chromatographic conditions for detecting ellagic acid in pomegranate peels using HPLC method. [Method] By using 0.2 mg/ml ellagic acid standard solution, on the basis of single-factor experiment and orthogonal experiment, chromatographic conditions (mobile phase ratio, flow rate, col- umn temperature) for detecting ellagic acid using HPLC were optimized. Based on the optimal chromatographic conditions, the ellagic acid content in experimental pomegranate peels was determined. [Resull] The optimal chromatographic conditions for detecting ellagic acid in pomegranate peels using HPLC method are: 1.2% phos- phoric acid:acetonitrile=85:15, column temperature of 35 ℃, and flow rate of 1.0 ml/min. The linear regression equation of ellagic acid is: y=2.9e+0.6x+4.4e+5 (FF=9 999). Ac- cording to the standard addition recovery test, the average recovery rate of ellagic acid is 98.20%, and RSD is 0.60%. Under above optimized chromatographic condi- tions, ellagic acid can be well separated from other interfering components in pomegranate peels, with shorter peak time and ideal effect, which is convenient for the detection in production practices. [Conclusion] This study laid the foundation for detecting ellagic acid in pomegranate peels using HPLC method.

  5. Peak load pricing in the electric utility industry

    Energy Technology Data Exchange (ETDEWEB)

    Wenders, J.T.

    In the electric utility industry, cost minimization requires that heterogeneous electric generation technologies be used to produce electricity demands of different durations. In contrast to the conclusions of traditional peak-load pricing theory, the existence of a heterogeneous capital stock means that off-peak marginal cost prices almost always should include some marginal capacity costs, and that the profit maximizing regulated electric utility may set peak price above marginal cost and off-peak price below marginal cost in order to encourage the expansion of capital-intensive base load generating capacity. (auth)

  6. Simple automatic strategy for background drift correction in chromatographic data analysis.

    Science.gov (United States)

    Fu, Hai-Yan; Li, He-Dong; Yu, Yong-Jie; Wang, Bing; Lu, Peng; Cui, Hua-Peng; Liu, Ping-Ping; She, Yuan-Bin

    2016-06-01

    Chromatographic background drift correction, which influences peak detection and time shift alignment results, is a critical stage in chromatographic data analysis. In this study, an automatic background drift correction methodology was developed. Local minimum values in a chromatogram were initially detected and organized as a new baseline vector. Iterative optimization was then employed to recognize outliers, which belong to the chromatographic peaks, in this vector, and update the outliers in the baseline until convergence. The optimized baseline vector was finally expanded into the original chromatogram, and linear interpolation was employed to estimate background drift in the chromatogram. The principle underlying the proposed method was confirmed using a complex gas chromatographic dataset. Finally, the proposed approach was applied to eliminate background drift in liquid chromatography quadrupole time-of-flight samples used in the metabolic study of Escherichia coli samples. The proposed method was comparable with three classical techniques: morphological weighted penalized least squares, moving window minimum value strategy and background drift correction by orthogonal subspace projection. The proposed method allows almost automatic implementation of background drift correction, which is convenient for practical use.

  7. Gas chromatographic determination of chloramphenicol residues in shrimp: interlaboratory study.

    Science.gov (United States)

    Munns, R K; Holland, D C; Roybal, J E; Storey, J M; Long, A R; Stehly, G R; Plakas, S M

    1994-01-01

    An interlaboratory study of a gas chromatographic method for determining chloramphenicol (CAP) residues in shrimp was conducted. An internal standard (Istd), the meta isomer of CAP, was added to the shrimp, and the treated shrimp were homogenized with ethyl acetate. The ethyl acetate extract was defatted with hexane, and the CAP was partitioned into ethyl acetate from an aqueous salt solution. The ethyl acetate was evaporated, and the dried residue was treated with Sylon, a trimethylsilyl derivatizing agent, to yield the trimethylsilyl derivative of CAP. A portion of the solution containing the derivative was injected into a gas chromatograph equipped with an electron capture detector. Levels of fortified and incurred CAP were calculated from the peak area ratio of standard CAP to Istd. Recoveries of CAP from tissue directly fortified at 5 ppb were 102% (within-laboratory relative standard deviation [RSDr] = 5.6%), 104% (RSDr = 5.5%), and 108% (RSDr = 6.3%) from Laboratories 1, 2, and 3, respectively. Incurred-CAP residues at 5 and 10 ppb levels were also determined, with the following results: Laboratory 1: composite A, 4.56 ppb (RSDr = 14.0%); composite B, 8.38 ppb (RSDr = 11.6%); Laboratory 2: composite A, 4.17 ppb (RSDr = 12.5%); composite B, 8.90 ppb (RSDr = 5.60%); Laboratory 3: composite A, 4.66 ppb (RSDr = 14.9%); composite B, 11.0 ppb (RSDr = 11.8%).

  8. Interpretative optimization of the isocratic ion chromatographic separation of anions

    Directory of Open Access Journals (Sweden)

    Todorović Žaklina N.

    2016-01-01

    Full Text Available Interpretive retention modeling was utilized to optimize the isocratic ion chromatographic (IC separation of the nine anions (formate, fluoride, chloride, nitrite, bromide, nitrate, phosphate, sulfate, oxalate. The carbonate-bicarbonate eluent was used and separation was done on a Dionex AS14 ion-exchange column. The influence of combined effects of two mobile phase factors, the total eluent concentration (2 - 6 mM and the carbonate/bicaronate ratio from 1:9 to 9:1 (which corespondent to pH range 9.35 - 11.27, on the IC separation was studied. The multiple species analyte/eluent model that takes into account ion-exchange equilibria of the eluent and sample anions was used. In order to estimate the parameters in the model, a non-linear fitting of the retention data, obtained at two-factor three-level experimental design, was applied. To find the optimal conditions in the experimental design, the normalized resolution product as a chromatographic objective function was employed. This criterion includes both the individual peak resolution and the total analysis time. A good agreement between experimental and simulated chromatograms was obtained. [Projekat Ministarstva nauke Republike Srbije, br. III43009

  9. 大容量核电机组接入川渝电网适应性及参与系统调峰研究%Adaptability of large-capacity nuclear power plants accessing Sichuan and Chongqing grids and ability of participating in system peak-load regulation

    Institute of Scientific and Technical Information of China (English)

    陈汉雄; 郑勇

    2011-01-01

    The grid adaptability after access of large capacity nuclear power plants in Sichuan-Chongqing grid is analyzed.The study focuses on problems in terms of load flow distribution,delivery line model selection,grid stability level, short circuit level and the ability to participate in system peak load regulation.The study results show that the reasonable accessing plan for large capacity nuclear power plant can satisfy the need for nuclear power delivery and control the system short circuit level.The large capacity nuclear power plant also has the ability to participate in system peak load regulation when needed,which reduces the quantity of abandoning energy in high flow period.It can also help Sichuan-Chongqing grid to improve comprehensive benefits on economic,social and environment aspects.%结合四川、重庆电网的实际系统,重点从电网的潮流分布、送出线路选型、电网稳定校核、短路电流水平计算以及是否参与系统调峰运行等多方面,研究分析2020年大容量核电机组(2x175万kW)接人川渝主干电网后对川渝电网的可能影响.研究表明:大容量核电机组较为合理的接人系统方案,既能满足核电送出需要,又可以控制系统短路电流水平,远景规划年份川渝主干电网总体上能适应大容量核电机组的接人系统;同时.大容量核电机组根据电网需要实时承担系统部分调峰任务后,可实现减少川渝电网丰期调峰弃水和节约燃煤的节能减排的经济、社会和环保等多方面综合效益.

  10. Improving the quality of biomarker candidates in untargeted metabolomics via peak table-based alignment of comprehensive two-dimensional gas chromatography-mass spectrometry data

    Science.gov (United States)

    Bean, Heather D.; Hill, Jane E.; Dimandja, Jean-Marie D.

    2015-01-01

    The potential of high-resolution analytical technologies like GC×GC/TOF MS in untargeted metabolomics and biomarker discovery has been limited by the development of fully automated software that can efficiently align and extract information from multiple chromatographic data sets. In this work we report the first investigation on a peak-by-peak basis of the chromatographic factors that impact GC×GC data alignment. A representative set of 16 compounds of different chromatographic characteristics were followed through the alignment of 63 GC×GC chromatograms. We found that varying the mass spectral match parameter had a significant influence on the alignment for poorly- resolved peaks, especially those at the extremes of the detector linear range, and no influence on well- chromatographed peaks. Therefore, optimized chromatography is required for proper GC×GC data alignment. Based on these observations, a workflow is presented for the conservative selection of biomarker candidates from untargeted metabolomics analyses. PMID:25857541

  11. Chromatographic Separation of Glucose and Fructose

    Science.gov (United States)

    Kuptsevich, Yu E.; Larionov, Oleg G.; Stal'naya, I. D.; Nakhapetyan, L. A.; Pronin, A. Ya

    1987-03-01

    The structures, mutarotation, and the physicochemical properties of glucose and fructose as well as methods for their separation are examined. Their chromatographic separation on cation exchangers in the calcium-form is discussed in detail. A theory of the formation of complexes of carbohydrates with metal cations is described and the mechanism of the separation of glucose and fructose on cation exchangers in the calcium-form is discussed in detail. Factors influencing the chromatographic separation of glucose and fructose on sulphonic acid cation-exchange resins are also considered. The bibliography includes 138 references.

  12. Geyser Peak Cabernet Sauvignon

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    <正>年份:2000产地:美国加州Sonoma County售价:$196 Geyser Peak(盖世峰)成立于1880年,是美国军有的过百岁葡萄酒庄。可惜美国酿制葡萄酒的技术在近三四十年才有突破,历史再悠久也没有太多帮助近二十年Geyser Peak就努力改进,希望迎头赶上其它加州新秀的水平,1989年,他们就聘请了澳洲Penfolds酒庄的酿酒师Daryl Groom,让旗下出品多了一份澳洲式的"霎眼娇"风格。2003年,Geyser Peak更在International Wine & Spirit Competition赢得"最佳美国葡萄酒生产商"大奖。

  13. High-performance liquid chromatographic column packings with different particle sizes: chromatographic behavior for the quality analysis of HuanglianShangqing pill.

    Science.gov (United States)

    Yang, Dongzhi; Li, Ying; Yang, Fangxiu; Du, Yan; Li, Yinjie; Zheng, Xiaoxiao; Tang, Daoquan

    2015-02-01

    The chromatographic separation of traditional Chinese medicines is still a highly challenging task in analytical science with respect to its hundreds and thousands of chemical compounds, while increase of separation efficiency can greatly improve the separation power of chromatographic column for traditional Chinese medicine. In this study, 13 bioactive components in HuanglianShangqing pill were selected as an index to optimize the separation conditions and evaluate the system suitability of three commercially available columns packed with 1.8, 3.5, and 5.0 μm particles. The chromatographic separations were obtained by the most appropriate Eclipse Plus C18 column (100 × 2.1 mm, 3.5 μm) within 45 min using gradient elution with aqueous-ammonium acetate (10 mmol/L, pH 5.0) and acetonitrile, at a flow rate of 0.3 mL/min and an operating temperature of 30°C. The quality of HuanglianShangqing pill was assessed through combining simultaneous quantification of 13 compounds with fingerprint analysis. For the qualitative analysis, mass spectrometry was used to confirm the 13 compounds. All the validation data conformed to the acceptable requirements. For the fingerprint analysis, 32 peaks were selected as the common peaks at 254 nm to evaluate the similarities among HuanglianShangqing pills obtained from ten manufacturers.

  14. VALIDATION OF AN EPA METHOD FOR THE ION CHROMATOGRAPHIC DETERMINATION OF PERCHLORATE IN FERTILIZERS USING A POLYVINYL ALCOHOL GEL RESIN.

    Science.gov (United States)

    This paper summarizes the key points of a joint study between the EPA and Metrohm-Peak, Inc., on the use of polyvinyl alcohol [PVA] columns for the ion chromatographic determination of percholorate in aqueous leachates or solutions of fertilizers. A series of fertilizer samples ...

  15. Chromatographic methods in the study of autism.

    Science.gov (United States)

    Żurawicz, Ewa; Kałużna-Czaplińska, Joanna; Rynkowski, Jacek

    2013-10-01

    Research into biomarkers of autism is a new means of medical intervention in this disease. Chromatographic techniques, especially coupled with mass spectrometry, are widely used in determination of biomarkers and assessment of effectiveness of autism therapy owing to their sensitivity and selectivity. Among the chromatographic techniques gas chromatography and liquid chromatography, especially high-performance liquid chromatography, have found application in clinical trials. The high-performance liquid chromatography technique allows an analysis of liquid samples with a wide range of molecules, small and large, providing an opportunity to perform advanced assays within a short time frame. Gas chromatography with the appropriate preparation of samples (gaseous and liquid) and a selection of analysis conditions enables the separation of thermally stable, volatile and non-volatile organic substances in short runtimes. The chromatographic techniques that are currently used in metabolic studies in autism are designed to identify abnormalities in three areas: the metabolism of neurotransmitters, nutritional and metabolic status and manifestations of oxidative stress. This review presents a necessary theoretical introduction and examples of applications of chromatographic studies of disorder markers in autism.

  16. 40 CFR 1065.267 - Gas chromatograph.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Gas chromatograph. 1065.267 Section 1065.267 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Hydrocarbon Measurements § 1065.267 Gas...

  17. Functional chromatographic technique for natural product isolation†

    Science.gov (United States)

    Lau, Eric C.; Mason, Damian J.; Eichhorst, Nicole; Engelder, Pearce; Mesa, Celestina; Kithsiri Wijeratne, E. M.; Gunaherath, G. M. Kamal B.; Leslie Gunatilaka, A. A.

    2015-01-01

    Natural product discovery arises through a unique interplay between chromatographic purification and biological assays. Currently, most techniques used for natural product purification deliver leads without a defined biological action. We now describe a technique, referred to herein as functional chromatography, that deploys biological affinity as the matrix for compound isolation. PMID:25588099

  18. Cyclic electrophoretic and chromatographic separation methods

    NARCIS (Netherlands)

    Eijkel, Jan C.T.; Berg, van den Albert; Manz, Andreas

    2004-01-01

    A review is given of the application of cyclic analytical methods in capillary electroseparation (CE) and liquid chromatography (LC) systems. Cyclic methods have been used since the early sixties in chromatographic systems to overcome pressure limitations to resolution. From the early nineties on th

  19. Functional chromatographic technique for natural product isolation†

    OpenAIRE

    Lau, Eric C.; Mason, Damian J.; Eichhorst, Nicole; Engelder, Pearce; Mesa, Celestina; Kithsiri Wijeratne, E. M.; Gunaherath, G. M. Kamal B.; Leslie Gunatilaka, A. A.; La Clair, James J.; Chapman, Eli

    2015-01-01

    Natural product discovery arises through a unique interplay between chromatographic purification and biological assays. Currently, most techniques used for natural product purification deliver leads without a defined biological action. We now describe a technique, referred to herein as functional chromatography, that deploys biological affinity as the matrix for compound isolation.

  20. [Comparison between the qualitative similarity and the quantitative similarity of chromatographic fingerprints of traditional Chinese medicines].

    Science.gov (United States)

    Sun, Guo-Xiang; Hou, Zhi-Fei; Zhang, Chun-Ling; Bi, Kai-Shun; Sun, Yu-Qing

    2007-01-01

    To explore the differences between the qualitative similarity and the quantitative similarity of chromatographic fingerprints of traditional Chinese medicines, the quantitative similarity calculated by vector shadow C%, apparent quantitative similarity R%, quantitative similarity P%, etc. were firstly proposed to disclose the quantitative information characteristics of traditional Chinese medicines fingerprints. The HPLC fingerprints of both the standard Fructus gardeniae and the ten batches of Fructus gardeniae produced in different places were evaluated by the new parameters to obtain good results. The contrasted fingerprint contained 35 peaks while geniposide was selected as the reference peak. The HPLC fingerprint had good precision and reproducibility with the RSD of the relative retention time less than 1.5% and the RSD of the relative peak area within 5%. The qualitative similarity and quantitative similarity between each crude drug and the contrasted fingerprint were quantitatively calculated, the values of C%, P%, etc., were applied in the quality control practice, which had less errors. What is more, this method could be used for the overall quality control of Fructus gardeniae and especially suits for qualitative and quantitative evaluations of the chromatographic fingerprints both in chemical constituent distribution and in contents. The quantitative parameters such as C% and P% can be used to objectively, authentically and thoroughly display the content information characteristics. When they combined with the qualitative similarity, it will be the good method to evaluate the chromatographic fingerprints of traditional Chinese medicines.

  1. Station Capacity

    DEFF Research Database (Denmark)

    Landex, Alex

    2011-01-01

    Stations are often limiting the capacity of railway networks. This is due to extra need of tracks when trains stand still, trains turning around, and conflicting train routes. Although stations are often the capacity bottlenecks, most capacity analysis methods focus on open line capacity. Therefore......, this paper presents methods to analyze station capacity. Four methods to analyze station capacity are developed. The first method is an adapted UIC 406 capacity method that can be used to analyze switch zones and platform tracks at stations that are not too complex. The second method examines the need...... the probability of conflicts and the minimum headway times into account. The last method analyzes how optimal platform tracks are used by examining the arrival and departure pattern of the trains. The developed methods can either be used separately to analyze specific characteristics of the capacity of a station...

  2. Tadpole toxicity prediction using chromatographic systems.

    Science.gov (United States)

    Fernández-Pumarega, Alejandro; Amézqueta, Susana; Fuguet, Elisabet; Rosés, Martí

    2015-10-30

    Toxicity has been emulated in tadpole species through chromatographic systems. The parameter studied to evaluate the non-specific toxicity of a compound is the narcosis concentration (Cnar), which is defined as the concentration needed for the immobilization of the organism. Because experimental investigation with animals is lengthy, costly, technically difficult, and ethically questionable, there is a great interest in developing surrogate physicochemical systems able to emulate biological systems to obtain the same information in a faster, more economic, and easier manner. In order to see which chromatographic systems would be able to emulate tadpole narcosis, both, tadpole narcosis data and data in several chromatographic and electrophoretic systems, were fitted to a linear solvation energy relationship (LSER) model. Thus, by comparison of the models it was possible to see which of the chromatographic systems were more similar to the biological one. The physicochemical systems that best emulate tadpole narcosis were an HPLC system based on an immobilized artificial membrane (IAM) column, and two micellar electrokinetic chromatography (MEKC) systems based on sodium taurocholate (STC) and a mixture of sodium dodecylsulphate (SDS) and Brij 35 as surfactants. A system based on a RP18 HPLC column also was selected for comparison because it is a common column in most analytical laboratories. To establish the models, a set of compounds with known Cnar values were analyzed in the chromatographic, and electrophoretic selected systems and, then, the retention factor (k) was correlated to the concentration of narcosis. Statistics showed that the system based on STC micelles was the best to emulate toxicity in tadpoles. The robustness and predictive ability of the developed models were validated.

  3. Peak mass and dynamical friction

    CERN Document Server

    Del Popolo, A

    1995-01-01

    We show how the results given by several authors relatively to the mass of a density peak are changed when small scale substructure induced by dynamical friction are taken into account. The peak mass obtained is compared to the result of Peacock \\& Heavens (1990) and to the peak mass when dynamical friction is absent to show how these effects conspire to reduce the mass accreted by the peak.

  4. Economic and safety analysis of unconventional peak regulation on power unit of peak shifting start-stop

    Science.gov (United States)

    Cao, X.; Zhao, J. F.; Duan, X. Q.; Jin, Y. A.

    2017-01-01

    Tthe capacity difference of peak regulation between the power gird and the actual demand has become a serious problem considering the growth in the difference between electricity supply and demand. Therefore, peak regulation of power grid needs to be deeply studied. Unconventional peak regulation on unit of peak shifting start-stop is a way that can broaden the range of power regulation, as well as benefit safe operation of the power grid. However, it requires frequent and fast unit start-stop, complex operation, and more staff labor. By carrying out unconventional thermal power unit load test, the start-stop mode of peak auxiliary equipment is studied in this paper, indicating that it has a positive effect on safety and economic of load-peaking operation. The best working conditions of the peak units is found by analysing consumption cost, safety specifications, and life lost of the start-stop peak regulation mode.

  5. Station Capacity

    DEFF Research Database (Denmark)

    Landex, Alex

    2011-01-01

    Stations are often limiting the capacity of railway networks. This is due to extra need of tracks when trains stand still, trains turning around, and conflicting train routes. Although stations are often the capacity bottlenecks, most capacity analysis methods focus on open line capacity. Therefore......, this paper presents methods to analyze station capacity. Four methods to analyze station capacity are developed. The first method is an adapted UIC 406 capacity method that can be used to analyze switch zones and platform tracks at stations that are not too complex. The second method examines the need...... for platform tracks and the probability that arriving trains will not get a platform track immediately at arrival. The third method is a scalable method that analyzes the conflicts in the switch zone(s). In its simplest stage, the method just analyzes the track layout while the more advanced stages also take...

  6. Effect of Rainfall on Traffic Stream Characteristics during Peak and Non-Peak Periods

    Directory of Open Access Journals (Sweden)

    Hashim Mohammed Alhassan

    2012-01-01

    Full Text Available This paper examined the effect of rainfall on traffic stream behaviour during  peak and non-peak periods on a basic highway section. Data on this section which is located on the J5 was collected for four months during which 99 rainfall events occurred. The traffic consisted of 75.80% cars, 10.23% motorcycles, 3.51% trucks and 10.46%  of other vehicles. Traffic was observed for both rain and no-rain conditions and the data was analysed to see the effect of the rain. The results showed decreases in the speed as the rain intensity increased. Similarly, the traffic flow rates decreased as the rain intensity increased. This trend was observed for both peak and non-peak periods and for both directions. It is concluded that the effect of rain during peak period could have more serious consequences on the traffic flow than during non-peak periods because of the higher flow rates and the constrained nature of the flow. Consequently, capacity degradations up to 30% during peak periods would require resources to be employed to manage the traffic.

  7. Smart templates for peak pattern matching with comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Reichenbach, Stephen E; Carr, Peter W; Stoll, Dwight R; Tao, Qingping

    2009-04-17

    Comprehensive two-dimensional liquid chromatography (LCxLC) generates information-rich but complex peak patterns that require automated processing for rapid chemical identification and classification. This paper describes a powerful approach and specific methods for peak pattern matching to identify and classify constituent peaks in data from LCxLC and other multidimensional chemical separations. The approach records a prototypical pattern of peaks with retention times and associated metadata, such as chemical identities and classes, in a template. Then, the template pattern is matched to the detected peaks in subsequent data and the metadata are copied from the template to identify and classify the matched peaks. Smart Templates employ rule-based constraints (e.g., multispectral matching) to increase matching accuracy. Experimental results demonstrate Smart Templates, with the combination of retention-time pattern matching and multispectral constraints, are accurate and robust with respect to changes in peak patterns associated with variable chromatographic conditions.

  8. Chemometric technique for the optimization of chromatographic system: Simultaneous HPLC determination of Rosuvastatin, Telmisartan, Ezetimibe and Atorvastatin used in combined cardiovascular therapy

    Directory of Open Access Journals (Sweden)

    V. Sree Janardhanan

    2016-11-01

    Full Text Available Developed and optimized a validated isocratic reverse phase HPLC separation of Rosuvastatin, Telmisartan, Ezetimibe and Atorvastatin in pharmaceutical preparation using response surface methodology. The separation was carried out by using phenomenex C18 column (15 cm × 4.6 mm id, 5 μm particle size and UV detection at 239 nm. The ranges of the independent variables used for the optimization were MeCN: 33–38%, buffer conc.: 10–20 mM and flow rate: 1–2 ml/min. The influence of these independent variables on the output responses: capacity factor of the first peak (k1, resolutions of the 2nd and 3rd peak (Rs2,3, and capacity factor of the fifth peak (k5 were evaluated. Using this strategy, a mathematical model was defined and a response surface was derived for the separation. The three responses were simultaneously optimized by using Derringer's desirability functions. Optimum conditions chosen for the assay were MeCN, MeOH, 20 mM K2HPO4 (pH 3.0 ± 0.2 solution (34.27:20:45.73 v/v/v and flow rate 2 ml/min. Total chromatographic analysis time per sample was approximately 10 min. The optimized assay condition was validated as per the ICH guidelines and applied for the quantitative analysis of Rosavel EZ, Avas-EZ and Lipisar 20 tablet. The developed method was simple, accurate and precise. Hence, it can be employed for the routine analysis in quality control laboratories.

  9. [Effect of emulsion on chromatographic process].

    Science.gov (United States)

    Jiang, Yulei; Li, Xi

    2004-11-01

    The types and features of concentration wave of the chromatographic process in which the mobile phase was emulsion were studied theoretically by the method of characteristics and the concept of multi mobile phase chromatography. When the mobile phase is an emulsion, solute is partitioned between the inner and outer phases of the emulsion as well as simultaneously adsorbed on the stationary phase resulting in the great difference of concentration profiles from the case in which the mobile phase is homogenous. The various profiles and mechanisms of concentration wave of the chromatographic process in which the partition relationship between the inner and outer phases of the emulsion and the adsorption isotherm on the stationary phase were both Langmuir-like were analyzed and discussed with corresponding examples, and the comparison with the case in which the mobile phase is homogenous is also done. It is shown that the chromatographic progress with emulsion is more complicated and multiple. The existence of multi mobile phases may sharpen simple wave to be shock wave or diffuse shock wave to be simple wave.

  10. Carrying Capacity

    DEFF Research Database (Denmark)

    Schroll, Henning; Andersen, Jan; Kjærgård, Bente

    2012-01-01

    A spatial planning act was introduced inIndonesia 1992 and renewed in 2008. It emphasised the planning role of decentralised authorities. The spatial planning act covers both spatial and environmental issues. It defines the concept of carrying capacity and includes definitions of supportive...... carrying capacity (SCC) and assimilative carrying capacity (ACC). The act mandates that the latter two aspects must be taken into consideration in the local spatial plans. The present study aimed at developing a background for a national guideline for carrying capacity in Indonesian provinces and districts...... standard or governmental political objective exists. In most cases it was possible to select a set of indicators, including thresholds that are workable in a carrying capacity planning at the local administrative levels. Not all relevant sectors at the decentralized level were included. Indicators of SCC...

  11. Chromatographic fingerprint similarity analysis for pollutant source identification.

    Science.gov (United States)

    Xie, Juan-Ping; Ni, Hong-Gang

    2015-12-01

    In the present study, a similarity analysis method was proposed to evaluate the source-sink relationships among environmental media for polybrominated diphenyl ethers (PBDEs), which were taken as the representative contaminants. Chromatographic fingerprint analysis has been widely used in the fields of natural products chemistry and forensic chemistry, but its application to environmental science has been limited. We established a library of various sources of media containing contaminants (e.g., plastics), recognizing that the establishment of a more comprehensive library allows for a better understanding of the sources of contamination. We then compared an environmental complex mixture (e.g., sediment, soil) with the profiles in the library. These comparisons could be used as the first step in source tracking. The cosine similarities between plastic and soil or sediment ranged from 0.53 to 0.68, suggesting that plastic in electronic waste is an important source of PBDEs in the environment, but it is not the only source. A similarity analysis between soil and sediment indicated that they have a source-sink relationship. Generally, the similarity analysis method can encompass more relevant information of complex mixtures in the environment than a profile-based approach that only focuses on target pollutants. There is an inherent advantage to creating a data matrix containing all peaks and their relative levels after matching the peaks based on retention times and peak areas. This data matrix can be used for source identification via a similarity analysis without quantitative or qualitative analysis of all chemicals in a sample.

  12. PEAK SHAVING CONSIDERING STREAMFLOW UNCERTAINTIES

    African Journals Online (AJOL)

    user

    The main thrust of this paper is peak shaving with a Stochastic hydro model. In peak sharing, the amount of ... Fuel cost at a conventional hydro plant is nil. On the other hand, the ... s(k) = spill at the hydro plant in period k. I(k) = loss due to ...

  13. How to use your peak flow meter

    Science.gov (United States)

    Peak flow meter - how to use; Asthma - peak flow meter; Reactive airway disease - peak flow meter; Bronchial asthma - peak flow meter ... If your airways are narrowed and blocked due to asthma, your peak flow values drop. You can ...

  14. Comparison among three anion exchange chromatographic supports to capture erythropoietin from cell culture supernatant

    Institute of Scientific and Technical Information of China (English)

    Lourdes HERNNDEZ; Diobel STEWART; Lourdes ZUMALACRREGUI; Daniel AMARO

    2015-01-01

    Affinity and ion exchange conventional chromatography have been used to capture erythropoietin ( EPO)from mammalian cell culture supernatant. Currently,chromatographic adsorbent perfusion is available, however a limited number of applications have been found in the literature. In this work,three anion exchange chromatographic supports( gel,membrane and monolithic)were evaluated in the capture step of the recombi-nant erythropoietin purification process. The influences of load and flow rate on each support performance were analyzed. Also the purity of the EPO molecules was determined. A productivity analysis,as a decision tool for larger scale implementation,was done. As a conclusion,the evaluated supports are technically suitable to cap-ture EPO with adequate recovery and good purity. However,the monolithic column admits high operating velocity,showing the highest adsorption capacity and productivity.

  15. A novel strategy for quantitative analysis of the formulated complex system using chromatographic fingerprints combined with some chemometric techniques.

    Science.gov (United States)

    Zhong, Xuan; Yan, Jun; Li, Yan-Chun; Kong, Bo; Lu, Hong-Bing; Liang, Yi-Zeng

    2014-11-28

    In this work, a novel strategy based on chromatographic fingerprints and some chemometric techniques is proposed for quantitative analysis of the formulated complex system. Here, the formulated complex system means a formulated type of complicated analytical system containing more than one kind of raw material under some concentration composition according to a certain formula. The strategy is elaborated by an example of quantitative determination of mixtures consist of three essential oils. Three key steps of the strategy are as follows: (1) remove baselines of the chromatograms; (2) align retention time; (3) conduct quantitative analysis using multivariate regression with entire chromatographic profiles. Through the determination of concentration compositions of nine mixtures arranged by uniform design, the feasibility of the proposed strategy is validated and the factors that influence the quantitative result are also discussed. This strategy is proved to be viable and the validation indicates that quantitative result obtained using this strategy mainly depends on the efficiency of the alignment method as well as chromatographic peak shape of the chromatograms. Previously, chromatographic fingerprints were only used for identification and/or recognition of some products. This work demonstrates that with the assistance of some effective chemometric techniques, chromatographic fingerprints are also potential and promising in solving quantitative problems of complex analytical systems.

  16. Full second order chromatographic/spectrometric data matrices for automated sample identification and component analysis by non-data-reducing image analysis

    DEFF Research Database (Denmark)

    Nielsen, Niles-Peter Vest; Smedsgaard, Jørn; Frisvad, Jens Christian

    1999-01-01

    A data analysis method is proposed for identification and for confirmation of classification schemes, based on single- or multiple-wavelength chromatographic profiles. The proposed method works directly on the chromatographic data without data reduction procedures such as peak area or retention...... index calculation, Chromatographic matrices from analysis of previously identified samples are used for generating a reference chromatogram for each class, and unidentified samples are compared with all reference chromatograms by calculating a resemblance measure for each reference. Once the method...... yielded over 90% agreement with accepted classifications. The method is highly accurate and may be used on all sorts of chromatographic profiles. Characteristic component analysis yielded results in good agreement with existing knowledge of characteristic components, but also succeeded in identifying new...

  17. Carrying Capacity

    DEFF Research Database (Denmark)

    Schroll, Henning; Andersen, Jan; Kjærgård, Bente

    2012-01-01

    A spatial planning act was introduced inIndonesia 1992 and renewed in 2008. It emphasised the planning role of decentralised authorities. The spatial planning act covers both spatial and environmental issues. It defines the concept of carrying capacity and includes definitions of supportive...... and ACC may increase the political focus on resources and environmental issues and may help to move local authorities towards a more holistic spatial planning approach. A carrying capacity approach could be an inspiration for local spatial planning in developing countries. A spatial planning act...... was introduced inIndonesia 1992 and renewed in 2008. It emphasised the planning role of decentralised authorities. The spatial planning act covers both spatial and environmental issues. It defines the concept of carrying capacity and includes definitions of supportive carrying capacity (SCC) and assimilative...

  18. Doppler peaks from active perturbations

    CERN Document Server

    Magueijo, J; Coulson, D; Ferreira, P; Magueijo, Joao; Albrecht, Andreas; Coulson, David; Ferreira, Pedro

    1995-01-01

    We examine how the qualitative structure of the Doppler peaks in the angular power spectrum of the cosmic microwave anisotropy depends on the fundamental nature of the perturbations which produced them. The formalism of Hu and Sugiyama is extended to treat models with cosmic defects. We discuss how perturbations can be ``active'' or ``passive'' and ``incoherent'' or ``coherent'', and show how causality and scale invariance play rather different roles in these various cases. We find that the existence of secondary Doppler peaks and the rough placing of the primary peak unambiguously reflect these basic properties.

  19. Packed multi-channels for parallel chromatographic separations in microchips.

    Science.gov (United States)

    Nagy, Andrea; Gaspar, Attila

    2013-08-23

    Here we report on a simple method to fabricate microfluidic chip incorporating multi-channel systems packed by conventional chromatographic particles without the use of frits. The retaining effectivities of different bottlenecks created in the channels were studied. For the parallel multi-channel chromatographic separations several channel patterns were designed. The obtained multipackings were applied for parallel separations of dyes. The implementation of several chromatographic separation units in microscopic size makes possible faster and high throughput separations.

  20. Identification and phylogeny of Arabian snakes: Comparison of venom chromatographic profiles versus 16S rRNA gene sequences

    Science.gov (United States)

    Al Asmari, Abdulrahman; Manthiri, Rajamohammed Abbas; Khan, Haseeb Ahmad

    2014-01-01

    Identification of snake species is important for various reasons including the emergency treatment of snake bite victims. We present a simple method for identification of six snake species using the gel filtration chromatographic profiles of their venoms. The venoms of Echis coloratus, Echis pyramidum, Cerastes gasperettii, Bitis arietans, Naja arabica, and Walterinnesia aegyptia were milked, lyophilized, diluted and centrifuged to separate the mucus from the venom. The clear supernatants were filtered and chromatographed on fast protein liquid chromatography (FPLC). We obtained the 16S rRNA gene sequences of the above species and performed phylogenetic analysis using the neighbor-joining method. The chromatograms of venoms from different snake species showed peculiar patterns based on the number and location of peaks. The dendrograms generated from similarity matrix based on the presence/absence of particular chromatographic peaks clearly differentiated Elapids from Viperids. Molecular cladistics using 16S rRNA gene sequences resulted in jumping clades while separating the members of these two families. These findings suggest that chromatographic profiles of snake venoms may provide a simple and reproducible chemical fingerprinting method for quick identification of snake species. However, the validation of this methodology requires further studies on large number of specimens from within and across species. PMID:25313278

  1. Make peak flow a habit!

    Science.gov (United States)

    ... asthma - peak flow References Durrani SR, Busse WW. Management of asthma in adolescents and adults. In: Adkinson NF Jr, Bochner BS, Burks AW, et al, eds. Middleton's Allergy Principles and Practice . 8th ed. Philadelphia, PA: Elsevier Saunders; 2014:chap ...

  2. Determination of solute descriptors by chromatographic methods

    Energy Technology Data Exchange (ETDEWEB)

    Poole, Colin F., E-mail: cfp@chem.wayne.edu [Department of Chemistry, Wayne State University, Detroit, MI 48202 (United States); Atapattu, Sanka N.; Poole, Salwa K.; Bell, Andrea K. [Department of Chemistry, Wayne State University, Detroit, MI 48202 (United States)

    2009-10-12

    The solvation parameter model is now well established as a useful tool for obtaining quantitative structure-property relationships for chemical, biomedical and environmental processes. The model correlates a free-energy related property of a system to six free-energy derived descriptors describing molecular properties. These molecular descriptors are defined as L (gas-liquid partition coefficient on hexadecane at 298 K), V (McGowan's characteristic volume), E (excess molar refraction), S (dipolarity/polarizability), A (hydrogen-bond acidity), and B (hydrogen-bond basicity). McGowan's characteristic volume is trivially calculated from structure and the excess molar refraction can be calculated for liquids from their refractive index and easily estimated for solids. The remaining four descriptors are derived by experiment using (largely) two-phase partitioning, chromatography, and solubility measurements. In this article, the use of gas chromatography, reversed-phase liquid chromatography, micellar electrokinetic chromatography, and two-phase partitioning for determining solute descriptors is described. A large database of experimental retention factors and partition coefficients is constructed after first applying selection tools to remove unreliable experimental values and an optimized collection of varied compounds with descriptor values suitable for calibrating chromatographic systems is presented. These optimized descriptors are demonstrated to be robust and more suitable than other groups of descriptors characterizing the separation properties of chromatographic systems.

  3. High performance hand-held gas chromatograph

    Energy Technology Data Exchange (ETDEWEB)

    Yu, C.M.

    1998-04-28

    The Microtechnology Center of Lawrence Livermore National Laboratory has developed a high performance hand-held, real time detection gas chromatograph (HHGC) by Micro-Electro-Mechanical-System (MEMS) technology. The total weight of this hand-held gas chromatograph is about five lbs., with a physical size of 8{close_quotes} x 5{close_quotes} x 3{close_quotes} including carrier gas and battery. It consumes about 12 watts of electrical power with a response time on the order of one to two minutes. This HHGC has an average effective theoretical plate of about 40k. Presently, its sensitivity is limited by its thermal sensitive detector at PPM. Like a conventional G.C., this HHGC consists mainly of three major components: (1) the sample injector, (2) the column, and (3) the detector with related electronics. The present HHGC injector is a modified version of the conventional injector. Its separation column is fabricated completely on silicon wafers by means of MEMS technology. This separation column has a circular cross section with a diameter of 100 pm. The detector developed for this hand-held GC is a thermal conductivity detector fabricated on a silicon nitride window by MEMS technology. A normal Wheatstone bridge is used. The signal is fed into a PC and displayed through LabView software.

  4. Liquid chromatographic determination of sennosides in Cassia angustifolia leaves.

    Science.gov (United States)

    Srivastava, Alpuna; Pandey, Richa; Verma, Ram K; Gupta, Madan M

    2006-01-01

    A simple liquid chromatographic method was developed for the determination of sennosides B and A in leaves of Cassia angustifolia. These compounds were extracted from leaves with a mixture of methanol-water (70 + 30, v/v) after defatting with hexane. Analyte separation and quantitation were achieved by gradient reversed-phase liquid chromatography and UV absorbance at 270 nm using a photodiode array detector. The method involves the use of an RP-18 Lichrocart reversed-phase column (5 microm, 125 x 4.0 mm id) and a binary gradient mobile-phase profile. The various other aspects of analysis, namely, peak purity, similarity, recovery, repeatability, and robustness, were validated. Average recoveries of 98.5 and 98.6%, with a coefficient of variation of 0.8 and 0.3%, were obtained by spiking sample solution with 3 different concentration solutions of standards (60, 100, and 200 microg/mL). Detection limits were 10 microg/mL for sennoside B and 35 microg/mL for sennoside A, present in the sample solution. The quantitation limits were 28 and 100 microg/mL. The analytical method was applied to a large number of senna leaf samples. The new method provides a reliable tool for rapid screening of C. angustifolia samples in large numbers, which is needed in breeding/genetic engineering and genetic mapping experiments.

  5. Peak Oil and other threatening peaks-Chimeras without substance

    Energy Technology Data Exchange (ETDEWEB)

    Radetzki, Marian, E-mail: marian@radetzki.bi [Lulea University of Technology (Sweden)

    2010-11-15

    The Peak Oil movement has widely spread its message about an impending peak in global oil production, caused by an inadequate resource base. On closer scrutiny, the underlying analysis is inconsistent, void of a theoretical foundation and without support in empirical observations. Global oil resources are huge and expanding, and pose no threat to continuing output growth within an extended time horizon. In contrast, temporary or prolonged supply crunches are indeed plausible, even likely, on account of growing resource nationalism denying access to efficient exploitation of the existing resource wealth.

  6. Peak Oil and other threatening peaks. Chimeras without substance

    Energy Technology Data Exchange (ETDEWEB)

    Radetzki, Marian [Luleaa University of Technology (Sweden)

    2010-11-15

    The Peak Oil movement has widely spread its message about an impending peak in global oil production, caused by an inadequate resource base. On closer scrutiny, the underlying analysis is inconsistent, void of a theoretical foundation and without support in empirical observations. Global oil resources are huge and expanding, and pose no threat to continuing output growth within an extended time horizon. In contrast, temporary or prolonged supply crunches are indeed plausible, even likely, on account of growing resource nationalism denying access to efficient exploitation of the existing resource wealth. (author)

  7. Ultrasonic Transducer Peak-to-Peak Optical Measurement

    Directory of Open Access Journals (Sweden)

    Pavel Skarvada

    2012-01-01

    Full Text Available Possible optical setups for measurement of the peak-to-peak value of an ultrasonic transducer are described in this work. The Michelson interferometer with the calibrated nanopositioner in reference path and laser Doppler vibrometer were used for the basic measurement of vibration displacement. Langevin type of ultrasonic transducer is used for the purposes of Electro-Ultrasonic Nonlinear Spectroscopy (EUNS. Parameters of produced mechanical vibration have to been well known for EUNS. Moreover, a monitoring of mechanical vibration frequency shift with a mass load and sample-transducer coupling is important for EUNS measurement.

  8. Chromatographic fingerprinting and quantitative analysis for the quality evaluation of Xinkeshu tablet

    Institute of Scientific and Technical Information of China (English)

    Pei Wang; Lian Li; Hailong Yang; Shijuan Cheng; Yingzi Zeng; Lei Nie; Hengchang Zang

    2012-01-01

    A simple, sensitive and accurate method based on high performance liquid chromato- graphy (HPLC) with diode array detector (DAD) was developed and validated for systematic quality evaluation of one type of traditional Chinese medicine preparations named Xinkeshu (XKS) tablet. In this study, the chromatographic fingerprints of XKS tablet were developed first, 23 peaks were selected as the common peaks to evaluate the similarities among different batches of XKS samples, which were manufactured in a long time span of three years. Additionally, simultaneous quantification of six markers in XKS tablet, including Danshensu, Protocatechuic aldehyde, Puerarin, Daidzin, Salvianolic acid B and Daidzein, was performed. The validation results showed that the developed method was specific, accurate, precise and robust. The preliminary explanation on why a close similarity between fingerprints did not exactly mean similar contents of chemical components in samples was given. The contribution of each chromatographic peak to similarity was also evaluated. The developed method offers an efficient, reliable and practical approach for systematic quality evaluation of XKS tablet.

  9. Quantitative high-performance liquid chromatographic determination of delta 4-3-ketosteroids in adrenocortical extracts.

    Science.gov (United States)

    Ballerini, R; Chinol, M; Ghelardoni, M

    1980-05-30

    A high-performance liquid chromatographic method is described for the determination of seven steroids in adrenocortical extracts showing a delta 4-3-ketonic conjugated system. The seven steroids (cortisol, cortisone, 11-dehydrocorticosterone, corticosterone, 11-deoxycortisol, aldosterone and 11-deoxycorticosterone) were separated with a chloroform-methanol gradient on a 5-micron silica column and with a water-acetonitrile gradient on a 10-micron RP-8 column. Effluents were monitored by UV absorption at 242 nm. Quantitative analysis was performed by comparing peak areas, which are proportional to the amounts of the individual substances (external standard method). The method is rapid, sensitive, easy to perform and reproducible.

  10. Trigonal tricationic ionic liquids: a generation of gas chromatographic stationary phases.

    Science.gov (United States)

    Payagala, Tharanga; Zhang, Ying; Wanigasekara, Eranda; Huang, Ke; Breitbach, Zachary S; Sharma, Pritesh S; Sidisky, Leonard M; Armstrong, Daniel W

    2009-01-01

    Trigonal tricationic ionic liquids (ILs) are a new class of ILs that appear to be unique when used as gas chromatographic stationary phases. They consist of four core structures; (1) A = mesitylene core, (2) B = benzene core, (3) C = triethylamine core, and (4) D = tri(2-hexanamido)ethylamine core; to which three identical imidazolium or phosphonium cationic moieties were attached. These were coated on fused silica capillaries, and their gas chromatographic properties were evaluated. They were characterized using a linear solvation parameter model and a number of test mixtures. On the basis of the literature, it is known that both monocationic and dicationic ILs possess almost identical polarities, solvation characteristics, and chromatographic selectivities. However, some of the trigonal tricationic ILs were quite different. The different solvation parameters and higher apparent polarities appear to generate from the more rigid trigonal geometry of these ILs, as well as their ability to retain the positive charges in relatively close proximity to one another in some cases. Their unique selectivities, retention behaviors, and separation efficiencies were demonstrated using the Grob mixture, a flavor and fragrance test mixture, alcohols/alkanes test, and FAME isomer separations. Two ILs C1 (methylimidazolium substitution) and C4 (2-hydroxyethylimidazolium substitution) had higher apparent polarities than any know IL (mono, di, and tricationic ILs) or commercial stationary phases. The tri(2-hexanamido)ethylamine core IL series proved to be very interesting in that it not only showed the highest separation efficiency for all test mixtures, but it also is the first IL stationary phase (containing NTf(2)(-) anions) that eliminates peak tailing for alcohols and other H-bonding analytes. The thermal stabilities were investigated using three methods: thermogravimetric analysis (TGA) method, temperature programmed gas chromatographic method (TPGC), and isothermal gas

  11. Significance Tests for Periodogram Peaks

    CERN Document Server

    Frescura, F A M; Frank, B S

    2007-01-01

    We discuss methods currently in use for determining the significance of peaks in the periodograms of time series. We discuss some general methods for constructing significance tests, false alarm probability functions, and the role played in these by independent random variables and by empirical and theoretical cumulative distribution functions. We also discuss the concept of "independent frequencies" in periodogram analysis. We propose a practical method for estimating the significance of periodogram peaks, applicable to all time series irrespective of the spacing of the data. This method, based on Monte Carlo simulations, produces significance tests that are tailor-made for any given astronomical time series.

  12. Liquid chromatographic determination of furazolidone in shrimp.

    Science.gov (United States)

    Stehly, G R; Plakas, S M; el Said, K R

    1994-01-01

    A liquid chromatographic (LC) method was developed for the quantitation of furazolidone residues in shrimp muscle. The shrimp homogenate (1.0 g) is extracted with acetonitrile, and the extract is taken to dryness. The residue is dissolved in acetonitrile, and the solution is passed through alumina and C18 cleanup columns. The eluate is taken to dryness and reconstituted in a suitable solvent for reversed-phase (C18) LC with UV detection at 365 nm. Recoveries of furazolidone from shrimp homogenates spiked from 5 to 80 ng/g ranged from 74.3 to 79.7%, and relative standard deviations (RSDs) were 5.0-8.9%. RSDs for incurred furazolidone quantitated at 5.9 and 9.2 ng/g were 6.6 and 7.6%, respectively.

  13. Simple gas chromatographic method for furfural analysis.

    Science.gov (United States)

    Gaspar, Elvira M S M; Lopes, João F

    2009-04-03

    A new, simple, gas chromatographic method was developed for the direct analysis of 5-hydroxymethylfurfural (5-HMF), 2-furfural (2-F) and 5-methylfurfural (5-MF) in liquid and water soluble foods, using direct immersion SPME coupled to GC-FID and/or GC-TOF-MS. The fiber (DVB/CAR/PDMS) conditions were optimized: pH effect, temperature, adsorption and desorption times. The method is simple and accurate (RSDTOF-MS: 0.3, 1.2 and 0.9 ngmL(-1) for 2-F, 5-MF and 5-HMF, respectively). It was applied to different commercial food matrices: honey, white, demerara, brown and yellow table sugars, and white and red balsamic vinegars. This one-step, sensitive and direct method for the analysis of furfurals will contribute to characterise and quantify their presence in the human diet.

  14. Functional Polymers for Chromatographic Enantiomer Separation

    Institute of Scientific and Technical Information of China (English)

    S. Allenmark; L. Thunberg

    2005-01-01

    @@ 1Introduction Today, methods to obtain pure enantiomers of organic compounds are of extreme importance, not the least due to the demands imposed on the pharmaceutical industry. Separation of the two enantiomers in a racemate is necessary in order to study possible differences in biological activity. Consequently, research on methods for direct chromatographic resolution by means of columns containing a chiral stationary phase (CSP) has been intense during the last decades and a wide variety of CSPs,many of which commercially available,exist today.Polymeric CSPs have been made from naturally occurring polymers (cellulose, amylose) via suitable derivatization, as well as either by polymerization of chiral monomers or via asymmetric catalysis to yield linear, isotactic polymers of a predominantly single-handed helicity. An excellent review of the field[1], with special emphasis on preparative applications, was published in 1994.

  15. Preparation of macroporous methacrylate-based monoliths for chromatographic applications by the Reactive Gelation Process.

    Science.gov (United States)

    Bechtle, M; Butté, A; Storti, G; Morbidelli, M

    2010-07-09

    Polymeric monoliths are a relatively new separation medium for chromatographic applications. The innovative approach to produce such monoliths, the Reactive Gelation Process, presented by Marti et al. [1] for polystyrene macroporous materials is applied to a methacrylate-based material. It is shown that it is possible to create a macroporous structure by Reactive Gelation also with this polymer even if the properties of the material are different. Besides the analysis of the material by SEM and BET, several chromatographic methods are used to analyze the material properties. The ISEC experiments showed a much smaller size exclusion effect than in conventional packed beds. The permeability of the material is comparable to a packed bed with 4.13 μm particles. The column efficiency is not changing for increasing flow rates. Because of the high efficiency of the material, shorter columns are needed and therefore the comparatively low permeability is compensated. The monolith also exhibits a significant adsorption capacity for hydrophobic interaction, which makes it suitable for chromatographic purification processes.

  16. Hubbert's Peak -- A Physicist's View

    Science.gov (United States)

    McDonald, Richard

    2011-04-01

    Oil, as used in agriculture and transportation, is the lifeblood of modern society. It is finite in quantity and will someday be exhausted. In 1956, Hubbert proposed a theory of resource production and applied it successfully to predict peak U.S. oil production in 1970. Bartlett extended this work in publications and lectures on the finite nature of oil and its production peak and depletion. Both Hubbert and Bartlett place peak world oil production at a similar time, essentially now. Central to these analyses are estimates of total ``oil in place'' obtained from engineering studies of oil reservoirs as this quantity determines the area under the Hubbert's Peak. Knowing the production history and the total oil in place allows us to make estimates of reserves, and therefore future oil availability. We will then examine reserves data for various countries, in particular OPEC countries, and see if these data tell us anything about the future availability of oil. Finally, we will comment on synthetic oil and the possibility of carbon-neutral synthetic oil for a sustainable future.

  17. Investigations into the chromatographic optimization of combined gas chromatographic/FTIR/MS

    Science.gov (United States)

    Wulff, Ditmar

    1989-12-01

    Even with the explosive growth and acceptance of GC/MS it has some analytical limitations. Several of these deficiencies can be overcome with information provided by GC/FTIR. Combining a GC/MS and a GC/FTIR into one system provides economies of sample, time, space, and money as well as a higher confidence qualitative result. The later results from the ability of the mass spectro -meter to give molecular fragment information with strength in homolog identification while the infrared spectrometer gives class specific-functional group and geometrical isomer data. Several configurations of the combined light pipe GC/FTIR/MS are evaluated looking toward ease of use, information content, and data evaluation. The combined system's sensitivity, chromatographic integrity, and gas chromatographic column choices and their operational parameters are discussed. The series arrangement with the GC column effluent passing through the FTIR light pipe and then serially to the MS is compared to the post column split of the column effluent to the FTIR and MS as well as to the configuration using two GC columns. Operational recommendations are given to maximize chromatographic resolution, detector sensitivity, and sample throughput. Examples are shown illustrating the combined systems operation. All parameters discussed apply to work done on the HP 5890A GC, the HP5965A IRD, and the HP 5970B MSD.

  18. Fuzzy C-means clustering for chromatographic fingerprints analysis: A gas chromatography-mass spectrometry case study.

    Science.gov (United States)

    Parastar, Hadi; Bazrafshan, Alisina

    2016-03-18

    Fuzzy C-means clustering (FCM) is proposed as a promising method for the clustering of chromatographic fingerprints of complex samples, such as essential oils. As an example, secondary metabolites of 14 citrus leaves samples are extracted and analyzed by gas chromatography-mass spectrometry (GC-MS). The obtained chromatographic fingerprints are divided to desired number of chromatographic regions. Owing to the fact that chromatographic problems, such as elution time shift and peak overlap can significantly affect the clustering results, therefore, each chromatographic region is analyzed using multivariate curve resolution-alternating least squares (MCR-ALS) to address these problems. Then, the resolved elution profiles are used to make a new data matrix based on peak areas of pure components to cluster by FCM. The FCM clustering parameters (i.e., fuzziness coefficient and number of cluster) are optimized by two different methods of partial least squares (PLS) as a conventional method and minimization of FCM objective function as our new idea. The results showed that minimization of FCM objective function is an easier and better way to optimize FCM clustering parameters. Then, the optimized FCM clustering algorithm is used to cluster samples and variables to figure out the similarities and dissimilarities among samples and to find discriminant secondary metabolites in each cluster (chemotype). Finally, the FCM clustering results are compared with those of principal component analysis (PCA), hierarchical cluster analysis (HCA) and Kohonon maps. The results confirmed the outperformance of FCM over the frequently used clustering algorithms. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Aligning of single and multiple wavelength chromatographic

    DEFF Research Database (Denmark)

    Nielsen, Niels-Peter Vest; Carstensen, Jens Michael; Smedsgaard, Jørn

    1998-01-01

    The use of chemometric data processing is becoming an important part of modern chromatography. Most chemometric analyses are performed on reduced data sets using areas of selected peaks detected in the chromatograms, which means a loss of data and introduces the problem of extracting peak data from...... containing the COW implementation used in this work may be obtained at http://www.imm.dtu.dk/~jmc/papers/cow/cow.html...

  20. Competence building capacity shortage

    Energy Technology Data Exchange (ETDEWEB)

    Doorman, Gerard; Wangensteen, Ivar; Bakken, Bjoern

    2005-02-01

    The objective of the project 'Competence Building Capacity Shortage' has been 'to increase knowledge about central approaches aimed at solving the peaking capacity problem in restructured power systems'. With respect to reserve markets, a model was developed in the project to analyze the relations between reserve requirements and prices in the spot and reserve markets respectively. A mathematical model was also developed and implemented, which also includes the balance market, and has a good ability to predict the relations between these markets under various assumptions. With some further development, this model can be used fore realistic analyses of these markets in a Nordic context. It was also concluded that certain system requirements with respect to frequency and time deviation can be relaxed without adverse effects. However, the requirements to system bias, Frequency Activated Operating Reserves and Frequency Activated Contingency Reserves cannot be relaxed, the latter because they must cover the dimensioning fault in the system. On the other hand, Fast Contingency Reserves can be reduced by removing requirements to national balances. Costs can furthermore be reduced by increasingly adapting a Nordic as opposed to national approach. A model for stepwise power flow was developed in the project, which is especially useful to analyze slow power system dynamics. This is relevant when analysing the effects of reserve requirements. A model for the analysis of the capacity balance in Norway and Sweden was also developed. This model is useful for looking at the future balance under various assumptions regarding e.g. weather conditions, demand growth and the development of the generation system. With respect to the present situation, if there is some price flexibility on the demand side and system operators are able to use reserves from the demand side, the probability for load shedding during the peak load hour is close to zero under the weather

  1. Longitudinal peak detected Schottky spectrum

    CERN Document Server

    Shaposhnikova, E

    2009-01-01

    The "peak detected Schottky" spectrum is a diagnostic used since the late seventies for beam observation in the SPS and now already applied to the LHC. This tool was always believed, however without proof, to give a good picture of the particle distribution in synchrotron frequencies similar to the longitudinal Schottky spectrum of unbunched beam for revolution frequencies.In this paper an analysis of this measurement technique is presented both in a general form and for the particular realisation in the SPS. In addition the limitations of the present experimental set-up are discussed together with possible improvements. The analysis shows that for an optimised experimental set-up the spectrum of the peak detected signal is very close to the synchrotron frequency distribution inside the bunch - much closer than that given by the traditional longitudinal bunched-beam Schottky spectrum.

  2. Chromatographic Separations of Enantiomers and Underivatized Oligosaccharides

    Energy Technology Data Exchange (ETDEWEB)

    Ying Liu

    2004-12-19

    My graduate research has focused on separation science and bioanalytical analysis, which emphasized in method development. It includes three major areas: enantiomeric separations using high performance liquid chromatography (HPLC), Super/subcritical fluid chromatography (SFC), and capillary electrophoresis (CE); drug-protein binding behavior studies using CE; and carbohydrate analysis using liquid chromatograph-electrospray ionization mass spectrometry (LC-ESI-MS). Enantiomeric separations continue to be extremely important in the pharmaceutical industry. An in-depth evaluation of the enantiomeric separation capabilities of macrocyclic glycopeptides CSPs with SFC mobile phases was investigated using a set of over 100 chiral compounds. It was found that the macrocyclic based CSPs were able to separate enantiomers of various compounds with different polarities and functionalities. Seventy percent of all separations were achieved in less than 4 min due to the high flow rate (4.0 ml/min) that can be used in SFC. Drug-protein binding is an important process in determining the activity and fate of a drug once it enters the body. Two drug/protein systems have been studied using frontal analysis CE method. More sensitive fluorescence detection was introduced in this assay, which overcame the problem of low sensitivity that is common when using UV detection for drug-protein studies. In addition, the first usage of an argon ion laser with 257 nm beam coupled with CCD camera as a frontal analysis detection method enabled the simultaneous observation of drug fluorescence as well as the protein fluorescence. LC-ESI-MS was used for the separation and characterization of underivatized oligosaccharide mixtures. With the limits of detection as low as 50 picograms, all individual components of oligosaccharide mixtures (up to 11 glucose-units long) were baseline resolved on a Cyclobond I 2000 column and detected using ESI-MS. This system is characterized by high chromatographic

  3. Chromatographic Separations of Enantiomers and Underivatized Oligosaccharides

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ying [Iowa State Univ., Ames, IA (United States)

    2004-01-01

    My graduate research has focused on separation science and bioanalytical analysis, which emphasized in method development. It includes three major areas: enantiomeric separations using high performance liquid chromatography (HPLC), Super/subcritical fluid chromatography (SFC), and capillary electrophoresis (CE); drug-protein binding behavior studies using CE; and carbohydrate analysis using liquid chromatograph-electrospray ionization mass spectrometry (LC-ESI-MS). Enantiomeric separations continue to be extremely important in the pharmaceutical industry. An in-depth evaluation of the enantiomeric separation capabilities of macrocyclic glycopeptides CSPs with SFC mobile phases was investigated using a set of over 100 chiral compounds. It was found that the macrocyclic based CSPs were able to separate enantiomers of various compounds with different polarities and functionalities. Seventy percent of all separations were achieved in less than 4 min due to the high flow rate (4.0 ml/min) that can be used in SFC. Drug-protein binding is an important process in determining the activity and fate of a drug once it enters the body. Two drug/protein systems have been studied using frontal analysis CE method. More sensitive fluorescence detection was introduced in this assay, which overcame the problem of low sensitivity that is common when using UV detection for drug-protein studies. In addition, the first usage of an argon ion laser with 257 nm beam coupled with CCD camera as a frontal analysis detection method enabled the simultaneous observation of drug fluorescence as well as the protein fluorescence. LC-ESI-MS was used for the separation and characterization of underivatized oligosaccharide mixtures. With the limits of detection as low as 50 picograms, all individual components of oligosaccharide mixtures (up to 11 glucose-units long) were baseline resolved on a Cyclobond I 2000 column and detected using ESI-MS. This system is characterized by high chromatographic

  4. Gas chromatographic determination of yohimbine in commercial yohimbe products.

    Science.gov (United States)

    Betz, J M; White, K D; der Marderosian, A H

    1995-01-01

    The bark of Pausinystalia yohimbe [K. Schumann] Pierre (Rubiaceae), long valued as an aphrodisiac in West Africa, recently has been promoted in the United States as a dietary supplement alternative to anabolic steroids for enhancement of athletic performance. As the number of yohimbe products on the retail market increases, concerns about their safety are raised because of the reported toxicity of yohimbine (the major alkaloid of the plant). Although plant materials are usually identified microscopically, we were unable to identify them in many of the products, because as their labels indicated, the products were mixtures of various botanicals or were bark extracts and contained little or no plant material. A method for extraction and capillary gas chromatographic (GC) separation of the alkaloids of P. yohimbe was, therefore, developed and used to analyze a number of commercial yohimbe products. The method involved solvent extraction and partitioning in chloroform-water followed by separation on a methyl silicone capillary GC column (N-P detection). Comparisons of chromatograms of extracts of authentic bark with those of commercial products indicated that, although many products contained measurable quantities of the alkaloid yohimbine, they were largely devoid of the other alkaloids previously reported in this species. Concentrations of yohimbine in the commercial products ranged from < 0.1 to 489 ppm, compared with 7089 ppm in the authentic material. Authentic bark has been reported to contain up to 6% total alkaloids, 10-15% of which are yohimbine. The possible presence of undeclared diluents in the products was indicated by peaks in product chromatograms but not in those of authentic bark.

  5. New supervised alignment method as a preprocessing tool for chromatographic data in metabolomic studies.

    Science.gov (United States)

    Struck, Wiktoria; Wiczling, Paweł; Waszczuk-Jankowska, Małgorzata; Kaliszan, Roman; Markuszewski, Michał Jan

    2012-09-21

    The purpose of this work was to develop a new aligning algorithm called supervised alignment and to compare its performance with the correlation optimized warping. The supervised alignment is based on a "supervised" selection of a few common peaks presented on each chromatogram. The selected peaks are aligned based on a difference in the retention time of the selected analytes in the sample and the reference chromatogram. The retention times of the fragments between known peaks are subsequently linearly interpolated. The performance of the proposed algorithm has been tested on a series of simulated and experimental chromatograms. The simulated chromatograms comprised analytes with a systematic or random retention time shifts. The experimental chromatographic (RP-HPLC) data have been obtained during the analysis of nucleosides from 208 urine samples and consists of both the systematic and random displacements. All the data sets have been aligned using the correlation optimized warping and the supervised alignment. The time required to complete the alignment, the overall complexity of both algorithms, and its performance measured by the average correlation coefficients are compared to assess performance of tested methods. In the case of systematic shifts, both methods lead to the successful alignment. However, for random shifts, the correlation optimized warping in comparison to the supervised alignment requires more time (few hours versus few minutes) and the quality of the alignment described as correlation coefficient of the newly aligned matrix is worse 0.8593 versus 0.9629. For the experimental dataset supervised alignment successfully aligns 208 samples using 10 prior identified peaks. The knowledge about retention times of few analytes' in the data sets is necessary to perform the supervised alignment for both systematic and random shifts. The supervised alignment method is faster, more effective and simpler preprocessing method than the correlation optimized

  6. Drivers of peak sales for pharmaceutical brands

    NARCIS (Netherlands)

    Fischer, Marc; Leeflang, Peter S. H.; Verhoef, Peter C.

    2010-01-01

    Peak sales are an important metric in the pharmaceutical industry. Specifically, managers are focused on the height-of-peak-sales and the time required achieving peak sales. We analyze how order of entry and quality affect the level of peak sales and the time-to-peak-sales of pharmaceutical brands.

  7. Liquid chromatographic assay for dicloxacillin in plasma.

    Science.gov (United States)

    Alderete, Oscar; González-Esquivel, Dinora F; Del Rivero, L Misael; Castro Torres, Nelly

    2004-06-15

    A simple high-performance liquid chromatographic method for the determination of dicloxacillin in plasma has been developed. The method only requires 0.5 ml of plasma, phosphate buffer solution (pH = 4.7), acidification with 0.5N hydrochloride acid and liquid extraction with dichloromethane. Posterior evaporation of organic under nitrogen steam and redissolution in mobile phase is carried out. The analysis was performed on a Spherisorb C18 (5 microm) column, using methanol -0.05 M phosphate buffer, pH = 4.7 (75:25; v/v) as mobile phase, with ultraviolet detection at 220 nm. Results showed that the assay is sensitive: 0.5 microg/ml. The response is linear in the range of 0.5 - 10 microg/ml. Maximum inter-day coefficient of variation was 12.4%. Mean extraction recovery obtained was 96.95%. Stability studies showed that the loss was not higher than 10%, samples are stable at room temperature for 6 h, at -20 Celsius for 2 months, processed samples were stable at least for 24 h and also after two freeze-thaw cycles. The method has been used to perform pharmacokinetic and bioequivalence studies in humans.

  8. Hydrophilic interaction chromatographic analysis of anthocyanins.

    Science.gov (United States)

    Willemse, Chandré M; Stander, Maria A; de Villiers, André

    2013-12-06

    Hydrophilic interaction chromatography (HILIC) provides an alternative separation mode for the analysis of phenolic compounds, in which aqueous-organic mobile phases with polar stationary phases are used. This paper reports the evaluation of HILIC for the analysis of the natural pigments anthocyanins, which are of importance because of their chromophoric properties and a range of health benefits associated with their consumption. Several HILIC stationary phases (silica, diol, amine, cyanopropyl and amide) and mobile phase combinations were evaluated, with the latter proving particularly important due to the distinctive chromatographic behaviour of anthocyanins. Diode array detection was used for selective detection of anthocyanins, while high resolution quadrupole-time-of-flight mass spectrometry (Q-TOF-MS) was used for compound identification. The potential of HILIC separation is demonstrated for a range of anthocyanins varying in glycosylation and acylation patterns found in blueberries, grape skins, black beans, red cabbage and red radish. HILIC is shown to be a complementary separation method to reversed phase liquid chromatography (RP-LC) due to the alternative retention mechanism.

  9. Chromatographic Separation of Vitamin E Enantiomers

    Directory of Open Access Journals (Sweden)

    Ju-Yen Fu

    2017-02-01

    Full Text Available Vitamin E is recognized as an essential vitamin since its discovery in 1922. Most vegetable oils contain a mixture of tocopherols and tocotrienols in the vitamin E composition. Structurally, tocopherols and tocotrienols share a similar chromanol ring and a side chain at the C-2 position. Owing to the three chiral centers in tocopherols, they can appear as eight different stereoisomers. Plant sources of tocopherol are naturally occurring in the form of RRR while synthetic tocopherols are usually in the form of all-racemic mixture. Similarly, with only one chiral center, natural tocotrienols occur as the R-isoform. In this review, we aim to discuss a few chromatographic methods that had been used to separate the stereoisomers of tocopherols and tocotrienols. These methods include high performance liquid chromatography, gas chromatography and combination of both. The review will focus on method development including selection of chiral columns, detection method and choice of elution solvent in the context of separation efficiency, resolution and chiral purity. The applications for separation of enantiomers in vitamin E will also be discussed especially in terms of the distinctive biological potency among the stereoisoforms.

  10. Capacity and Capacity Utilization in Fishing Industries

    OpenAIRE

    Kirkley, James E; Squires, Dale

    1999-01-01

    Excess capacity of fishing fleets is one of the most pressing problems facing the world's fisheries and the sustainable harvesting of resource stocks. Considerable confusion persists over the definition and measurement of capacity and capacity utilization in fishing. Fishing capacity and capacity utilization, rather than capital (or effort) utilization, provide the appropriate framework. This paper provides both technological-economic and economic definitions of capacity and excess capacity i...

  11. Chromatographic and mass spectrometric techniques in studies on oxidative stress in autism.

    Science.gov (United States)

    Kałużna-Czaplińska, Joanna; Jóźwik-Pruska, Jagoda

    2016-04-15

    Healthy body is characterized by the presence of a dynamic and balanced equilibrium between the production of reactive oxygen species (ROS) and the antioxidant capacity. In oxidative stress this balance is switched to reactions of oxidation leading to increased production of ROS, exceeding the capacity of physiological antioxidant systems. Oxidative stress is known to be linked to many disturbances, disorders and diseases. One of these is the autism spectrum disorder (ASD). ASD is a neurodevelopmental disorder manifested by abnormalities in social communication and interaction, as well as by occurrence of repetitive, restricted patterns of behavior or activities. It is believed that adequate knowledge about the oxidative stress biomarkers and the possibility of their reliable measuring could be useful in broadening knowledge on various diseases including ASD. A high number of compounds have been proposed as biomarkers of oxidative stress. Some of these are connected with the severity of ASD. The present review gives a summary of the chromatographic techniques used for the determination of biomarkers for oxidative stress in autism, and of other compounds important in this context. The first part of the review focuses on the correlation between oxidative stress and autism. The second part describes applications of chromatographic and mass spectrometric methods to the analysis of different metabolites connected with oxidative stress in biological fluids of autistic children. Advantages as well as disadvantages of the application of these methods for the analysis of different types of oxidative stress biomarkers are discussed.

  12. Radiolytic stability of some recently developed ion exchange and extraction chromatographic resins containing diphosphonic acid groups

    Energy Technology Data Exchange (ETDEWEB)

    Chiarizia, R.; Horwitz, E.P.

    2000-01-01

    The effect of {sup 60}Co irradiation on the Diphonix{trademark}, Diphosil and Diphonix-CS chelating ion exchange resins, and on two Dipex{trademark} extraction chromatographic resins containing the P,P{prime}-di(2-ethylhexyl) methanediphosphonic acid (H{sub 2}DEH[MDP]) impregnated in the pores of a polymeric support (Dipex-1) and of silica (Dipex-2), respectively, has been investigated. The resins have been irradiated while in contact with HNO{sub 3} (Diphonix, Diphosil and Dipex resins) or NaOH (Diphonix-DS resin) up to an absorbed dose of about 200 Mrad. As a probe of the resin radiolytic degradation, metal uptake (both equilibrium and kinetics) and capacity measurements have been performed. Results show that the Diphonix-CS resin properties are practically unaffected by irradiation under the experimental conditions used in this work. The Diphonix, Diphosil, and especially the Dipex resins suffer substantial capacity losses, but their affinity for actinide ions is not seriously compromised. On the other hand, the kinetics of metal uptake by the silica based Diphosil and Dipex-2 resins becomes substantially slower indicating that, from a radiolytic degradation standpoint, polymeric materials perform better than silica as supports for H{sub 2}DEH[MDP] containing extraction chromatographic resins.

  13. Characterization of crude oils and petroleum products: (I Elution liquid chromatographic separation and gas chromatographic analysis of crude oils and petroleum products

    Directory of Open Access Journals (Sweden)

    E.O. Odebunmi

    2002-12-01

    Full Text Available Some physical and chemical properties of samples of light, medium and heavy Nigerian crude oils and petroleum products including gasoline, kerosene and engine oil have been measured and are reported in this paper. The crude oils and petroleum products have also been characterized by fractional distillation and elution liquid chromatography. The fractions obtained from elution liquid chromatography were analyzed using gas chromatography (GC. The GC fractions were identified by comparing the retention time of peaks in the unknown samples with those of components of calibration standard mixtures. The importance of the physico-chemical properties and the significance of the fractional distillation and chromatographic separation methods to industrial process operations have been discussed.

  14. Ion chromatographic separation of inorganic ions using a combination of hydrophilic interaction chromatographic column and cation-exchange resin column.

    Science.gov (United States)

    Arai, Kaori; Mori, Masanobu; Hironaga, Takahiro; Itabashi, Hideyuki; Tanaka, Kazuhiko

    2012-04-01

    A combination of hydrophilic interaction chromatographic (HILIC) column and a weakly acidic cation-exchange resin (WCX) column was used for simultaneous separation of inorganic anions and cations by ion chromatography (IC). Firstly, the capability of HILIC column for the separation of analyte ions was evaluated under acidic eluent conditions. The columns used were SeQuant ZIC-HILIC (ZIC-HILIC) with a sulfobetaine-zwitterion stationary phase (ZIC-HILIC) and Acclaim HILIC-10 with a diol stationary phase (HILIC-10). When using tartaric acid as the eluent, the HILIC columns indicated strong retentions for anions, based on ion-pair interaction. Especially, HILIC-10 could strongly retain anions compared with ZIC-HILIC. The selectivity for analyte anions of HILIC-10 with 5 mmol/L tartaric acid eluent was in the order of I(-) > NO3(-) > Br(-) > Cl(-) > H2PO4(-). However, since HILIC-10 could not separate analyte cations, a WCX column (TSKgel Super IC-A/C) was connected after the HILIC column in series. The combination column system of HILIC and WCX columns could successfully separate ten ions (Na+, NH4+, K+, Mg2+, Ca2+, H2PO4(-), Cl(-), Br(-), NO3(-) and I(-)) with elution of 4 mmol/L tartaric acid plus 8 mmol/L 18-crown-6. The relative standard deviations (RSDs) of analyte ions by the system were in the ranges of 0.02% - 0.05% in retention times and 0.18% - 5.3% in peak areas through three-time successive injections. The limits of detection at signal-to-noise ratio of 3 were 0.24 - 0.30 micromol/L for the cations and 0.31 - 1.2 micromol/L for the anions. This system was applied for the simultaneous determination of the cations and the anions in a vegetable juice sample with satisfactory results.

  15. Gas chromatographic separation of hydrogen isotopes using metal hydrides

    Energy Technology Data Exchange (ETDEWEB)

    Aldridge, F.T.

    1984-05-09

    A study was made of the properties of metal hydrides which may be suitable for use in chromatographic separation of hydrogen isotopes. Sixty-five alloys were measured, with the best having a hydrogen-deuterium separation factor of 1.35 at 60/sup 0/C. Chromatographic columns using these alloys produced deuterium enrichments of up to 3.6 in a single pass, using natural abundance hydrogen as starting material. 25 references, 16 figures, 4 tables.

  16. Gas-chromatographic determination of aluminum in catalytic systems

    Energy Technology Data Exchange (ETDEWEB)

    Astapova, T.I.; Kutepova, A.I.; Frolova, O.D.

    1987-11-10

    The authors studied conditions for the chromatographic determination of aluminum in the form of a complex with pentane-2,4-dione in pilot plant-produced samples of GIAP-16, GIAP-16-2, SPM catalysts, talums and kaolins, aluminum oxides, and hydroxides. The influence of Zn, Mg, Ca, Na, Ni, Ti, and Mn on the extraction and the chromatographic determination of aluminum was studied.

  17. A new chromatographic response function for use in size-exclusion chromatography optimization strategies: Application to complex organic mixtures.

    Science.gov (United States)

    Duarte, Regina M B O; Duarte, Armando C

    2010-11-26

    A new chromatographic response function (CRF) is presented aiming at designing an optimal chromatographic separation protocol for assessing the molecular size distribution of complex organic mixtures, such as those of natural organic matter from different sources (atmospheric, aqueous, and terrestrial). This CRF can be applied to mixtures of unknown solutes, being well suited for describing separation processes of pair of peaks of highly unequal area, and also for overlapping and asymmetric peaks. The performance of the developed CRF was compared to that of an existing response function, using simulated chromatograms. The capability of the new function to qualify the resolution degree that it is attained under different chromatographic conditions was further assessed through a size-exclusion chromatography study of a variety of different organic compounds, via a two-level full factorial design. It was proved that this function is a reliable alternative to optimize simultaneously the composition of the mobile phase (pH, ionic strength, and organic modifier concentration) and the instrumental variables (flow rate).

  18. Fundulus heteroclitus gonadotropins.5: Small scale chromatographic fractionation of pituitary extracts into components with different steroidogenic activities using homologous bioassays

    Directory of Open Access Journals (Sweden)

    Petrino Teresa R

    2004-03-01

    Full Text Available Abstract Fractionation and characterization of gonadotropins (GtH from Fundulus heteroclitus pituitary extracts were carried out using a biocompatible liquid chromatographic procedure (Pharmacia FPLC system. Chromatographic fractions were monitored for gonadotropic activities (induction of oocyte maturation and steroid production using homologous follicle bioassays in vitro. Size-exclusion chromatography eluted gonadotropic activity in one major protein peak (Mr ~ 30,000. Anion-exchange and hydrophobic-interaction chromatography (HIC yielded two distinct peaks of 17beta-estradiol (E2- and 17alpha-hydroxy,20beta-dihydroprogesterone (DHP-promoting activity with associated oocyte maturation. Two-dimensional chromatography (chromatofocusing followed by HIC resolved pituitary extracts into two active fractions; both induced E2 synthesis, but one was relatively poor in eliciting DHP and testosterone production. Thus, using homologous bioassays, at least two quantitatively different gonadotropic (steroidogenic activities: an E2-promoting gonadotropin (GtH I-like and a DHP-promoting gonadotropin (GtH II-like, which has a lower isoelectric point but greater hydrophobicity than the former, can be distinguished from F. heteroclitus pituitaries by a variety of chromatographic procedures. This study complements previous biochemical and molecular data in F. heteroclitus and substantiates the duality of GtH function in a multiple-spawning teleost.

  19. Fundulus heteroclitus gonadotropins.5: Small scale chromatographic fractionation of pituitary extracts into components with different steroidogenic activities using homologous bioassays

    Science.gov (United States)

    Lin, Yu-Wai Peter; Petrino, Teresa R; Wallace, Robin A

    2004-01-01

    Fractionation and characterization of gonadotropins (GtH) from Fundulus heteroclitus pituitary extracts were carried out using a biocompatible liquid chromatographic procedure (Pharmacia FPLC system). Chromatographic fractions were monitored for gonadotropic activities (induction of oocyte maturation and steroid production) using homologous follicle bioassays in vitro. Size-exclusion chromatography eluted gonadotropic activity in one major protein peak (Mr ~ 30,000). Anion-exchange and hydrophobic-interaction chromatography (HIC) yielded two distinct peaks of 17beta-estradiol (E2)- and 17alpha-hydroxy,20beta-dihydroprogesterone (DHP)-promoting activity with associated oocyte maturation. Two-dimensional chromatography (chromatofocusing followed by HIC) resolved pituitary extracts into two active fractions; both induced E2 synthesis, but one was relatively poor in eliciting DHP and testosterone production. Thus, using homologous bioassays, at least two quantitatively different gonadotropic (steroidogenic) activities: an E2-promoting gonadotropin (GtH I-like) and a DHP-promoting gonadotropin (GtH II-like), which has a lower isoelectric point but greater hydrophobicity than the former, can be distinguished from F. heteroclitus pituitaries by a variety of chromatographic procedures. This study complements previous biochemical and molecular data in F. heteroclitus and substantiates the duality of GtH function in a multiple-spawning teleost. PMID:15040801

  20. Aerobic capacity related to cardiac size in young children

    DEFF Research Database (Denmark)

    Dencker, M; Wollmer, P; Karlsson, M

    2013-01-01

    Aerobic capacity, defined as peak oxygen uptake (VO2PEAK), is generally considered to be the best single marker for aerobic fitness. We assessed if VO2PEAK is related to different cardiac dimensions in healthy young children on a population base.......Aerobic capacity, defined as peak oxygen uptake (VO2PEAK), is generally considered to be the best single marker for aerobic fitness. We assessed if VO2PEAK is related to different cardiac dimensions in healthy young children on a population base....

  1. Aerobic capacity related to cardiac size in young children

    DEFF Research Database (Denmark)

    Dencker, M; Wollmer, P; Karlsson, M

    2013-01-01

    Aerobic capacity, defined as peak oxygen uptake (VO2PEAK), is generally considered to be the best single marker for aerobic fitness. We assessed if VO2PEAK is related to different cardiac dimensions in healthy young children on a population base.......Aerobic capacity, defined as peak oxygen uptake (VO2PEAK), is generally considered to be the best single marker for aerobic fitness. We assessed if VO2PEAK is related to different cardiac dimensions in healthy young children on a population base....

  2. Quantifying process tradeoffs in the operation of chromatographic sequences.

    Science.gov (United States)

    Ngiam, Sheau-Huey; Bracewell, Daniel G; Zhou, Yuhong; Titchener-Hooker, Nigel J

    2003-01-01

    A method for the rapid representation of key process tradeoffs that need to be made during the analysis of chromatographic sequences has been proposed. It involves the construction of fractionation and maximum purification factor versus yield diagrams, which can be completed easily on the basis of chromatographic data. The output of the framework developed reflects the degree of tradeoff between levels of yield and purity and provides a fast and precise prediction of the sample fraction collection strategy needed to meet a desired process specification. The usefulness of this approach for the purposes of product purification and contaminant removal in a single chromatographic step has been successfully demonstrated in an earlier paper and it is now extended by application to a chromatographic sequence: the separation of a hypothetical three-component protein system by hydrophobic interaction chromatography (HIC) followed by size exclusion chromatography (SEC). The HIC operation has a strong impact upon the subsequent SEC step. The studies show how the analysis of performance in such a chromatographic sequence can be carried out easily and in a straightforward fashion using the fractionation diagram approach. The methodology proposed serves as a useful tool for identifying the process tradeoffs that must be made during operation of a sequence of chromatographic steps and indicates the impact on further processing of the cut-point decisions that are made.

  3. Chromatographic Enantioseparations in Achiral Environments: Myth or Truth?

    Science.gov (United States)

    Martens, Jürgen; Bhushan, Ravi; Sajewicz, Mieczyslaw; Kowalska, Teresa

    2017-08-01

    Direct chromatographic enantioseparations are among the most important practical tasks of chromatography. The accepted rules and concepts of stereochemistry anticipated one type of chromatographic systems applicable only to such enantioseparations consisting either of chiral stationary phase, or chiral selector present in mobile phase. In such a model of chromatographic system, both racemic and non-racemic mixtures could be enantioseparated. Over the years, however, reports on successful chiral enantioseparations in non-chiral chromatographic systems have cumulated as well. To adapt the initial model to novel experimental evidence, an assumption had to be added stating that these were only non-racemic mixtures (and not racemic ones), which could be enantioseparated in achiral chromatographic systems, by granting them an inevitable chirality from the enantiomeric excess of a more abundant enantiomer. There still exists an overlooked portion of experimental evidence for successful enantioseparations of racemic mixtures in the non-chiral chromatographic systems, which cannot be explained by the accepted model. Facing this incompatibility between the model and practical results, we reflect on how to reconcile these two by questioning the possibility of pinpointing a true racemate with the help of our imperfect analytical tools. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Towards ultra-high peak capacities and peak-production rates using spatial three-dimensional liquid chromatography

    NARCIS (Netherlands)

    Wouters, B.; Davydova, E.; Wouters, S.; Vivo-Truyols, G.; Schoenmakers, P.J.; Eeltink, S.

    2015-01-01

    In order to successfully tackle the truly complex separation problems arising from areas such as proteomics research, the development of ultra-efficient and fast separation technology is required. In spatial three-dimensional chromatography, components are separated in the space domain with each

  5. Quantitative analysis combined with chromatographic fingerprint for comprehensive evaluation of Xiaoer Chaigui Tuire granules by HPLC-DAD.

    Science.gov (United States)

    Liu, Hong-Ming; Nie, Lei

    2015-01-01

    Quantitative analysis of eight major components combined with chromatographic fingerprint based on high performance liquid chromatography coupled with diode array detector (HPLC-DAD) was developed for the quality evaluation of Xiaoer Chaigui Tuire granules (XCTG), a traditional Chinese medicine (TCM) preparation. Each compound was analyzed by comparing its retention time and UV spectrum of each chromatographic peak with the corresponding retention time and UV spectrum of each standard compound. Baseline separation was achieved on an Agilent Zorbax SB-C18 column with gradient elution of acetonitrile and 0.1% (v/v) phosphoric acid. The developed method was validated by linearity, precision, repeatability, stability and recovery and was subsequently applied to quality evaluation of 12 batches of XCTG with similarity analysis, principal component analysis and cluster analysis. Quantitative analysis combined with HPLC fingerprint could offer an efficient, reliable and practical approach for quality evaluation of XCTG.

  6. Simultaneous chromatographic fingerprinting and quantitative analysis of flavonoids in Pollen Typhae by high-performance capillary electrophoresis

    Directory of Open Access Journals (Sweden)

    Le Han

    2012-12-01

    Full Text Available To evaluate the quality of Pollen Typhae as used in traditional Chinese medicine, a high-performance capillary electrophoresis (HPCE method has been developed, validated and applied to chromatographic fingerprinting and quantitation of its eight main bioactive flavonoids (naringenin, isorhamnetin 3-O-(2G-α-l-rhamnosyl-rutinoside, rhamnetin 3-O-neohesperidoside, isorhamnetin, quercetin 3-O-(2G-α-l-rhamnosyl-rutinoside, quercetin 3-O-neohesperidoside, kaempferol and quercetin. Fingerprinting was based on the selection of nine characteristic chromatographic peaks. In quantitative analysis, the recovery of all eight compounds was in the range 98.5–102.2% with good linearity (r2>0.9919 over a relatively wide concentration range. The assay was successfully applied to the analysis of the eight bioactive flavonoids in 14 different samples. The results indicate that the assay is reproducible and precise and can be used for convenient quality assessment of Pollen Typhae.

  7. Cornflower (Centaurea cyanus L.) honey quality parameters: chromatographic fingerprints, chemical biomarkers, antioxidant capacity and others.

    Science.gov (United States)

    Kuś, Piotr Marek; Jerković, Igor; Tuberoso, Carlo Ignazio Giovanni; Marijanović, Zvonimir; Congiu, Francesca

    2014-01-01

    The samples of cornflower (Centaurea cyanus L.) honey from Poland were subjected to ultrasonic solvent extraction applying the mixture of pentane and diethyl ether 1:2v/v (solvent A) as well as dichloromethane (solvent B). The major compounds of the extracts (analysed by GC-MS/GC-FID) were C13 and C9 norisoprenoids. Among them, (E)-3-oxo-retro-α-ionol (2.4-23.9% (solvent A); 3.9-14.4% (solvent B)) and (Z)-3-oxo-retro-α-ionol (3.7-29.9% (solvent A); 8.4-20.4% (solvent B)) were found to be useful as chemical biomarkers of this honey. Other abundant compounds were: methyl syringate (0.0-31.4% (solvent A); 0.0-25.4% (solvent B)) and 3-hydroxy-4-phenylbutan-2-one (1.6-15.8% (solvent A); 5.1-15.1% (solvent B)). HPLC-DAD analysis of the samples revealed lumichrome (4.7-10.0mg/kg), riboflavin (1.9-2.7mg/kg) and phenyllactic acid (112.1-250.5mg/kg) as typical compounds for this honey type. Antioxidant and antiradical properties as well as total phenolic content of the samples were found to be rather moderate by FRAP (ferric reducing antioxidant power), DPPH (1,1-diphenyl-2-picrylhydrazyl radical) and Folin-Ciocalteu assays, respectively. Additionally, CIE L(∗)a(∗)b(∗)C(∗)h chromatic coordinates were evaluated. Colour attributes of cornflower honey were characterised by elevated values of L(∗) and particularly high values of b(∗) and h coordinates, which correspond to medium bright honey with intense yellow colour.

  8. Neurofeedback training for peak performance

    Directory of Open Access Journals (Sweden)

    Marek Graczyk

    2014-11-01

    Full Text Available [b]aim[/b]. One of the applications of the Neurofeedback methodology is peak performance in sport. The protocols of the neurofeedback are usually based on an assessment of the spectral parameters of spontaneous EEG in resting state conditions. The aim of the paper was to study whether the intensive neurofeedback training of a well-functioning Olympic athlete who has lost his performance confidence after injury in sport, could change the brain functioning reflected in changes in spontaneous EEG and event related potentials (ERPs. [b]case study[/b]. The case is presented of an Olympic athlete who has lost his performance confidence after injury in sport. He wanted to resume his activities by means of neurofeedback training. His QEEG/ERP parameters were assessed before and after 4 intensive sessions of neurotherapy. Dramatic and statistically significant changes that could not be explained by error measurement were observed in the patient. [b]conclusion[/b]. Neurofeedback training in the subject under study increased the amplitude of the monitoring component of ERPs generated in the anterior cingulate cortex, accompanied by an increase in beta activity over the medial prefrontal cortex. Taking these changes together, it can be concluded that that even a few sessions of neurofeedback in a high performance brain can significantly activate the prefrontal cortical areas associated with increasing confidence in sport performance.

  9. Peak Detection Using Wavelet Transform

    Directory of Open Access Journals (Sweden)

    Omar Daoud

    2014-07-01

    Full Text Available A new work based-wavelet transform is designed to o vercome one of the main drawbacks that found in the present new technologies. Orthogonal Frequency Divi sion Multiplexing (OFDMis proposed in the literature to enhance the multimedia resolution. Ho wever, the high peak power (PAPR values will obstr uct such achievements. Therefore, a new proposition is found in this work, making use of the wavelet transforms methods, and it is divided into three ma in stages; de-noising stage, thresholding stage and then the replacement stage. In order to check the system stages validity; a mat hematical model has been built and its checked afte r using a MATLAB simulation. A simulated bit error ra te (BER achievement will be compared with our previously published work, where an enhancement fro m 8×10 -1 to be 5×10 -1 is achieved. Moreover, these results will be compared to the work found in the l iterature, where we have accomplished around 27% PAPR extra reduction. As a result, the BER performance has been improved for the same bandwidth occupancy. Moreover and due to the de-noise stage, the verification rate ha s been improved to reach 81%. This is in addition t o the noise immunity enhancement.

  10. QbD-oriented development and validation of a bioanalytical method for nevirapine with enhanced liquid-liquid extraction and chromatographic separation.

    Science.gov (United States)

    Beg, Sarwar; Chaudhary, Vandna; Sharma, Gajanand; Garg, Babita; Panda, Sagar Suman; Singh, Bhupinder

    2016-06-01

    The present studies describe the systematic quality by design (QbD)-oriented development and validation of a simple, rapid, sensitive and cost-effective reversed-phase HPLC bioanalytical method for nevirapine in rat plasma. Chromatographic separation was carried out on a C18 column using isocratic 68:9:23% v/v elution of methanol, acetonitrile and water (pH 3, adjusted by orthophosphoric acid) at a flow rate of 1.0 mL/min using UV detection at 230 nm. A Box-Behnken design was applied for chromatographic method optimization taking mobile phase ratio, pH and flow rate as the critical method parameters (CMPs) from screening studies. Peak area, retention time, theoretical plates and peak tailing were measured as the critical analytical attributes (CAAs). Further, the bioanalytical liquid-liquid extraction process was optimized using an optimal design by selecting extraction time, centrifugation speed and temperature as the CMPs for percentage recovery of nevirapine as the CAA. The search for an optimum chromatographic solution was conducted through numerical desirability function. Validation studies performed as per the US Food and Drug Administration requirements revealed results within the acceptance limit. In a nutshell, the studies successfully demonstrate the utility of analytical QbD approach for the rational development of a bioanalytical method with enhanced chromatographic separation and recovery of nevirapine in rat plasma. Copyright © 2015 John Wiley & Sons, Ltd.

  11. Development and validation of a specific stability indicating high performance liquid chromatographic method for rizatriptan benzoate.

    Science.gov (United States)

    Mallikarjuna Rao, B; Sangaraju, Sivaiah; Srinivasu, M K; Madhavan, P; Lalitha Devi, M; Rajendra Kumar, P; Chandrasekhar, K B; Arpitha, Ch; Satya Balaji, T

    2006-06-16

    A gradient, reversed-phase liquid chromatographic (RP-LC) method was developed for the quantitative determination of rizatriptan benzoate, used to treat relieves migraine headache symptoms. The developed method can be also employed for the related substance determination in bulk samples. Forced degradation studies were performed on bulk sample of rizatriptan benzoate using acid (0.5 N hydrochloric acid), base (0.1 N sodium hydroxide), oxidation (3.0% hydrogen peroxide), water hydrolysis, heat (60 degrees C) and photolytic degradation. Mild degradation of the drug substance was observed in base hydrolysis and considerable degradation observed during oxidative stress. The chromatographic method was fine tuned using the samples generated from forced degradation studies. Good resolution between the peaks corresponds to degradation products and the analyte was achieved on Agilent Zorbax SB-CN (250 mm x 4.6 mm, 5 microm) column. The mobile phase consists of a mixture of aqueous potassium di hydrogen ortho phosphate (pH 3.4), acetonitrile and methanol. The stress sample solutions were assayed against the qualified reference standard of rizatriptan benzoate and the mass balance in each case was close to 99.7% indicating that the developed method is stability indicating. Validation of the developed method was carried out as per ICH requirements.

  12. Remotely detected NMR for the characterization of flow and fast chromatographic separations using organic polymer monoliths.

    Science.gov (United States)

    Teisseyre, Thomas Z; Urban, Jiri; Halpern-Manners, Nicholas W; Chambers, Stuart D; Bajaj, Vikram S; Svec, Frantisek; Pines, Alexander

    2011-08-01

    An application of remotely detected magnetic resonance imaging is demonstrated for the characterization of flow and the detection of fast, small molecule separations within hypercrosslinked polymer monoliths. The hyper-cross-linked monoliths exhibited excellent ruggedness, with a transit time relative standard deviation of less than 2.1%, even after more than 300 column volumes were pumped through at high pressure and flow. Magnetic resonance imaging enabled high-resolution intensity and velocity-encoded images of mobile phase flow through the monolith. The images confirm that the presence of a polymer monolith within the capillary disrupts the parabolic laminar flow profile that is characteristic of mobile phase flow within an open tube. As a result, the mobile phase and analytes are equally distributed in the radial direction throughout the monolith. Also, in-line monitoring of chromatographic separations of small molecules at high flow rates is shown. The coupling of monolithic chromatography columns and NMR provides both real-time peak detection and chemical shift information for small aromatic molecules. These experiments demonstrate the unique power of magnetic resonance, both direct and remote, in studying chromatographic processes.

  13. Facility Location with Double-peaked Preferences

    DEFF Research Database (Denmark)

    Filos-Ratsikas, Aris; Li, Minming; Zhang, Jie

    2015-01-01

    We study the problem of locating a single facility on a real line based on the reports of self-interested agents, when agents have double-peaked preferences, with the peaks being on opposite sides of their locations. We observe that double-peaked preferences capture real-life scenarios and thus...... complement the well-studied notion of single-peaked preferences. We mainly focus on the case where peaks are equidistant from the agents’ locations and discuss how our results extend to more general settings. We show that most of the results for single-peaked preferences do not directly apply to this setting...

  14. Power Allocation for Fading Channels with Peak-to-Average Power Constraints

    CERN Document Server

    Nguyen, Khoa D; Rasmussen, Lars K

    2008-01-01

    Power allocation with peak-to-average power ratio constraints is investigated for transmission over Nakagami-m fading channels with arbitrary input distributions. In the case of delay-limited block-fading channels, we find the solution to the minimum outage power allocation scheme with peak-to-average power constraints and arbitrary input distributions, and show that the signal-to-noise ratio exponent for any finite peak-to-average power ratio is the same as that of the peak-power limited problem, resulting in an error floor. In the case of the ergodic fully-interleaved channel, we find the power allocation rule that yields the maximal information rate for an arbitrary input distribution and show that capacities with peak-to-average power ratio constraints, even for small ratios, are very close to capacities without peak-power restrictions.

  15. Continuous melting and ion chromatographic analyses of ice cores.

    Science.gov (United States)

    Huber, T M; Schwikowski, M; Gäggele, H W

    2001-06-22

    A new method for determining concentrations of organic and inorganic ions in ice cores by continuous melting and contemporaneous ion chromatographic analyses was developed. A subcore is melted on a melting device and the meltwater produced is collected in two parallel sample loops and then analyzed simultaneously by two ion chromatographs, one for anions and one for cations. For most of the analyzed species, lower or equal blank values were achieved with the continuous melting and analysis technique compared to the conventional analysis. Comparison of the continuous melting and ion chromatographic analysis with the conventional analysis of a real ice core segment showed good agreement in concentration profiles and total amounts of ionic species. Thus, the newly developed method is well suited for ice core analysis and has the advantages of lower ice consumption, less time-consuming sample preparation and lower risk of contamination.

  16. Physicochemical and chromatographic method of characterization of Matricaria recutita tinctures

    Directory of Open Access Journals (Sweden)

    Jonathan Parra

    2016-02-01

    Full Text Available Context: The pharmacological activity of medicinal products containing plant materials depends on their specific components. However, these components are not characterized in their entirety in all cases. Therefore, manufacturing processes must be duly characterized and validated. Aims: To characterize a chamomile (Matricaria recutita tincture through chemometric analysis of chromatographic data in order to establish quality parameters for its production. Methods: Various chamomile tinctures were manufactured and the precision and robustness of the production process for each was verified. The physicochemical properties of the tinctures were characterized and their chromatographic digital fingerprints analysed through chemometric methods. Results: A good correlation between the physicochemical characterization and the chromatographic analysis was demonstrated. The preparation methodology was proved to be repeatable as long as the source of the plant material is not altered. Conclusions: The principal component multivariate analysis of chromatograms was a helpful and simple tool for the characterization and traceability of the production method.

  17. Scope of partial least-squares regression applied to the enantiomeric composition determination of ketoprofen from strongly overlapped chromatographic profiles.

    Science.gov (United States)

    Padró, Juan M; Osorio-Grisales, Jaiver; Arancibia, Juan A; Olivieri, Alejandro C; Castells, Cecilia B

    2015-07-01

    Valuable quantitative information could be obtained from strongly overlapped chromatographic profiles of two enantiomers by using proper chemometric methods. Complete separation profiles where the peaks are fully resolved are difficult to achieve in chiral separation methods, and this becomes a particularly severe problem in case that the analyst needs to measure the chiral purity, i.e., when one of the enantiomers is present in the sample in very low concentrations. In this report, we explore the scope of a multivariate chemometric technique based on unfolded partial least-squares regression, as a mathematical tool to solve this quite frequent difficulty. This technique was applied to obtain quantitative results from partially overlapped chromatographic profiles of R- and S-ketoprofen, with different values of enantioresolution factors (from 0.81 down to less than 0.2 resolution units), and also at several different S:R enantiomeric ratios. Enantiomeric purity below 1% was determined with excellent precision even from almost completely overlapped signals. All these assays were tested on the most demanding condition, i.e., when the minor peak elutes immediately after the main peak. The results were validated using univariate calibration of completely resolved profiles and the method applied to the determination of enantiomeric purity of commercial pharmaceuticals.

  18. Liquid Chromatographic-Chemometric Techniques for the Simultaneous HPLC Determination of Lansoprazole, Amoxicillin and Clarithromycin in Commercial Preparation.

    Science.gov (United States)

    Aktas, A Hakan; Saridag, Ayse Mine

    2017-09-01

    Two multivariate calibration-prediction techniques, principal component regression (PCR) and partial least-squares regression (PLSR) were applied to the chromatographic multicomponent analysis of the drug containing lansoprazole (LAN), clarithromycin (CLA) and amoxicillin (AMO). Optimum chromatographic separation of LAN, CLA and AMO with atorvastatin as the internal standard (IS) was obtained by using Xterra® RP18 column 5 μm 4.6 × 250 mm2, and 25 mM ammonium chloride buffer prepared ammonium chloride, acetonitrile and bidistilled water (45:45:10 v/v) as the mobile phase at flow rate 1.0 mL/min. The high pressure liquid chromatography data sets consisting of the ratios of analyte peak areas to the IS peak area were obtained by using diode array detector detection at five wavelengths (205, 210, 215, 220 and 225 nm). LC-chemometric calibration for LAN, CLA and AMO were separately constructed by using the relationship between the peak-area ratio and training sets for each analyte. A series of synthetic solutions containing different concentrations of LAN, CLA and AMO were used to check the prediction ability of the PCR and PLS. Both of the two-chemometric methods in this study can be satisfactorily used for the quantitative analysis and for dissolutions tests of multicomponent commercial drug. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Ion chromatographic separation of inorganic ions using a combination of hydrophilic interaction chromatographic column and cation-exchange resin column

    Institute of Scientific and Technical Information of China (English)

    Kaori ARAI; Masanobu MORI; Takahiro HIRONAGA; Hideyuki ITABASHI; Kazuhiko TANAKA

    2012-01-01

    A combination of hydrophilic interaction chromatographic ( HILIC ) column and a weakly acidic cation-exchange resin (WCX) column was used for simultaneous separation of inorganic anions and cations by ion chromatography ( IC ).Firstly,the capability of HILIC column for the separation of analyte ions was evaluated under acidic eluent conditions.The columns used were SeQuant ZIC-HILIC (ZIC-HILIC) with a sulfobetainezwitterion stationary phase (ZIC-HILIC) and Acclaim HILIC-10 with a diol stationary phase (HILIC-10).When using tartaric acid as the eluent,the HILIC columns indicated strong retentions for anions,based on ion-pair interaction.Especially,HILIC-10 could strongly retain anions compared with ZIC-HILIC. The selectivity for analyte anions of HILIC-10 with 5 mmol/L tartaric acid eluent was in the order of I- > NO3- > Br- > Cl- >H2PO4-.However,since HILIC-10 could not separate analyte cations,a WCX column (TSKgel Super IC-A/C) was connected after the HILIC column in series.The combination column system of HILIC and WCX columns could successfully separate ten ions (Na+,NH4+,K+,Mg2+,Ca2+,H2PO4-,Cl-,Br-,NO3- and I-) with elution of 4 mmol/L tartaric acid plus 8 mmol/L 18-crown-6.The relative standard deviations (RSDs) of analyte ions by the system were in the ranges of 0.02% - 0.05% in retention times and 0.18% - 5.3% in peak areas through three-time successive injections.The limits of detection at signal-to-noise ratio of 3 were 0.24 - 0.30 μmol/L for the cations and 0.31 - 1.2 μmol/L for the anions.This system was applied for the simultaneous determination of the cations and the anions in a vegetable juice sample with satisfactory results.

  20. Computerised gas chromatographic-mass spectrometric analysis of complex mixtures of alkyl porphyrins.

    Science.gov (United States)

    Marriott, P J; Gill, J P; Evershed, R P; Hein, C S; Eglinton, G

    1984-01-01

    Computerised capillary gas chromatography-mass spectrometry (GC-MS) analysis of complex mixtures of alkyl porphyrins, as their bis-(trimethylsiloxy)silicon(IV) and bis(tert.-butyldimethylsiloxy)silicon(IV) derivatives, is described. The latter derivative is more suitable for routine GC-MS analysis. This computerised GC-MS approach, when applied to the alkyl porphyrins of two geological samples, a bitumen (Gilsonite, Eocene age, UT, U.S.A.) and a crude oil (Boscan, Cretaceous age, West Venezuela), has revealed the highly complex compositions of these fractions. Computer-aided data processing, using relative retention index (RRI) calculations, facilitated the classification of the chromatographic peaks according to structural type and membership of pseudo-homologous series. Computerised GC-MS is compared with, and contrasted to high-performance liquid chromatography as a means of petroporphyrin analysis.

  1. [Chromatographic analysis of low molecular weight fraction of cerebrospinal fluid in children with acute neuroinfections].

    Science.gov (United States)

    Alekseeva, L A; Shatik, S V; Sorokina, M N; Karasev, V V

    2002-05-01

    Low molecular-weight (oligopeptide) fraction of the cerebrospinal fluid was analyzed by high-performance reversed phase liquid chromatography in 30 children with bacterial and viral neuroinfections. The incidence and height of chromathoraphic peaks in bacterial meningitis depended on the disease etiology, stage, and severity. Qualitative and quantitative composition of low molecular-weight fraction of the liquor varied in patients with viral neuroinfections, depending on the severity of the cerebral parenchyma involvement. Differences in chromatographic profiles in complicated and uneventful course of neuroinfections indicate a possible damaging, protective, or regulatory effect of the liquor peptides. These data focus the attention on the role of oligopeptides in the genesis of neuroinfectious process, significance of search for peptide markers, their further isolation, identification, and development of test systems available for clinical application.

  2. A digital algorithm for spectral deconvolution with noise filtering and peak picking: NOFIPP-DECON

    Science.gov (United States)

    Edwards, T. R.; Settle, G. L.; Knight, R. D.

    1975-01-01

    Noise-filtering, peak-picking deconvolution software incorporates multiple convoluted convolute integers and multiparameter optimization pattern search. The two theories are described and three aspects of the software package are discussed in detail. Noise-filtering deconvolution was applied to a number of experimental cases ranging from noisy, nondispersive X-ray analyzer data to very noisy photoelectric polarimeter data. Comparisons were made with published infrared data, and a man-machine interactive language has evolved for assisting in very difficult cases. A modified version of the program is being used for routine preprocessing of mass spectral and gas chromatographic data.

  3. Different reactivities of amphetamines with N-methyl-bis(trifluoroacetamide) in heated gas chromatographic injectors.

    Science.gov (United States)

    Hidvégi, E; Hideg, Zs; Somogyi, G P

    2008-03-01

    A fast gas chromatographic mass spectrometric method has been developed earlier for the determination of amphetamine derivatives in human serum and urine. For derivatization, N-methyl-bis(trifluoroacetamide) (MBTFA) was used. Derivatization was performed using an on-line mode, since 1 microl of MBTFA and 1 microl sample extract, dissolved in toluene were injected simultaneously. In this study, the reactivity of the several amphetamine type analytes with MBTFA was investigated. MBTFA used for flash derivatization was applied undiluted on the one hand and diluted 4--4096-fold with acetonitrile on the other hand. Studying several amphetamines in the test sample spiked at the same concentrations we found that they could be divided into 3 groups based on relative target ion peak areas as a function of MBTFA dilution. Group 1, containing only primary amines showed an early increase of the relative peak areas if we increased MBTFA concentration, where group 2 (mainly N-methyl secondary amines) showed that relative peak areas started to increase intensively at higher MBTFA concentrations. Finally, MDEA as an N-ethyl secondary amine, representing group 3, showed significant increase if only slightly diluted MBTFA was used as a flash reagent. This phenomenon can be explained mainly with the less and less reactivity of amine groups in the case of groups 2 and 3, compared to group 1. These findings could help to optimise analytical methods involving flash derivatization processes.

  4. A new method to evaluate the similarity of chromatographic fingerprints: weighted pearson product-moment correlation coefficient.

    Science.gov (United States)

    Liu, Yongsuo; Meng, Qinghua; Chen, Rong; Wang, Jiansong; Jiang, Shumin; Hu, Yuzhu

    2004-01-01

    The Pearson product-moment correlation coefficient is being used to evaluate the similarity of the high-performance liquid chromatographic fingerprints of traditional Chinese medicine (TCM) in China. It is confirmed that a large range of peak areas produced the wrong results. A new algorithm concerning weighted Pearson product-moment correlation coefficient is proposed in this article. The results for both real cases and simulated data sets show that the weighted Pearson product-moment correlation coefficients allow relatively larger differences for large values, smaller differences for small values, and more reliable results than the unweighted Pearson product-moment correlation coefficients. Weight selection depends on the specific scientific problem.

  5. 27 CFR 9.140 - Atlas Peak.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Atlas Peak. 9.140 Section... THE TREASURY LIQUORS AMERICAN VITICULTURAL AREAS Approved American Viticultural Areas § 9.140 Atlas Peak. (a) Name. The name of the viticultural area described in this section is “Atlas Peak.”...

  6. Development and validation of a reversed-phase liquid chromatographic method for analysis of demeclocycline and related impurities.

    Science.gov (United States)

    Kahsay, Getu; Maxa, Jaroslav; Van Schepdael, Ann; Hoogmartens, Jos; Adams, Erwin

    2012-06-01

    A simple, robust, and rapid reversedphase high-performance liquid chromatographic method for the analysis of demeclocycline and its impurities is described. Chromatographic separations were achieved on a Symmetry Shield RP8 (75 mm × 4.6 mm, 3.5 μm) column kept at 40°C. The mobile phase was a gradient mixture of acetonitrile, 0.06 M sodium edetate (pH 7.5), 0.06 M tetrapropylammonium hydrogen sulphate (pH 7.5) and water, A (2:35:35:28 v/v/v/v) and B (30:35:35:0 v/v/v/v) pumped at a flow rate of 1 mL/min. UV detection was performed at 280 nm. The developed method was validated according to the ICH guidelines for specificity, limit of detection, limit of quantification, linearity, precision, and robustness. An experimental design was applied for robustness study. Results show that the peak shape, chromatographic resolution between the impurities, and the total analysis time are satisfactory and better than previous methods. The method has been applied for the analysis of commercial demeclocycline bulk samples available on the market.

  7. Chromatographic separation of inorganic ions on thin layers of titanium phosphate ion-exchanger.

    Science.gov (United States)

    Ghoulipour, Vanik; Safari, Moharram

    2014-12-01

    The chromatographic behavior of 30 inorganic cations has been studied on thin layers of titanium phosphate ion-exchanger using several aqueous, organic and mixed mobile phases. The separation of one ion from several other ions and also ternary and binary separations have been developed. Some important analytical separations are reported. The effect of pH of the mobile phase on retention factor (Rf) values of the cations in the presence of complex-forming anion along with the separation power of the ion-exchanger were studied. This ion-exchanger exhibits high sorption capacity and varying selectivity towards metal ions and makes it a suitable stationaiy phase in thin layer chromatography.

  8. Chromatographic separation of inorganic ions on thin layers of titanium phosphate ion-exchanger

    Institute of Scientific and Technical Information of China (English)

    Vanik GHOULIPOUR; Moharram SAFARI

    2014-01-01

    The chromatographic behavior of 30 inorganic cations has been studied on thin layers of titanium phosphate ion-exchanger using several aqueous,organic and mixed mobile phases. The separation of one ion from several other ions and also ternary and binary separations have been developed. Some important analytical separations are reported. The effect of pH of the mobile phase on retention factor(Rf)values of the cations in the presence of complex-forming anion along with the separation power of the ion-exchanger were studied. This ion-exchanger exhibits high sorption capacity and varying selectivity towards metal ions and makes it a suitable stationary phase in thin layer chromatography.

  9. Chromatographic separation of cytidine triphosphate from fermentation broth of yeast using anion-exchange cryogel.

    Science.gov (United States)

    Wang, Lianghua; Shen, Shaochuan; Yun, Junxian; Yao, Kejian; Yao, Shan-Jing

    2008-03-01

    A novel separation method was developed to isolate directly cytidine triphosphate (CTP) from fermentation broth of yeast using anion-exchange supermacroporous cryogel. The anion-exchange cryogel with tertiary amine groups was prepared by graft polymerization. The breakthrough characteristics and elution performance of pure CTP in the cryogel bed were investigated experimentally and the CTP binding capacity was determined. Then the separation experiments of CTP from crude fermentation broth of yeast using the cryogel column were carried out using deionized water and 0.01 M HCl as washing buffer, respectively. The chromatographic behavior was monitored and analyzed. The purity and concentration of the obtained CTP in these processes were determined quantitatively by HPLC. The maximal purity of CTP obtained at the condition of 0.01 M HCl as washing buffer and 0.5 M NaCl in 0.01 M HCl as elution buffer reached 93%.

  10. Poor compensatory hyperventilation in morbidly obese women at peak exercise.

    Science.gov (United States)

    Zavorsky, Gerald S; Murias, Juan M; Kim, Do Jun; Gow, Jennifer; Christou, Nicolas V

    2007-11-15

    This study was designed to compare differences in pulmonary gas exchange at rest and at peak exercise in two groups of women: (1) physically active, non-obese women and (2) women with morbid obesity. Fourteen morbidly obese women (body mass index or BMI=49+/-7 kg/m2; peak oxygen consumption or VO2 peak=14+/-2 ml/(kg min)) and 14 physically active non-obese women (BMI=22+/-2 kg/m2; VO2 peak=50+/-6 ml/(kg min)) performed an incremental, ramped exercise test to exhaustion on a cycle ergometer. Arterial blood was sampled at rest and at peak exercise. At rest, the alveolar to arterial oxygen partial pressure difference was 3x higher in the obese women (14+/-10 mmHg) compared to non-obese women (5+/-4 mmHg). Arterial carbon dioxide pressure (PaCO2) was identical in both groups at rest (37+/-4 mmHg). Only the non-obese women showed a decrease in PaCO2 rest to peak exercise (-5+/-3 mmHg). The slope between heart rate and VO2 during exercise was higher in the morbidly obese compared to non-obese women indicating that for the same absolute increase in VO2 a larger increase in heart rate is needed, demonstrating poorer cardiac efficiency in obese women. In conclusion, morbidly obese women have poorer exercise capacity, cardiac efficiency, and compensatory hyperventilation at peak exercise, and poorer gas exchange at rest compared to physically active, non-obese women.

  11. Improving accuracy in the quantitation of overlapping, asymmetric, chromatographie peaks by deconvolution: theory and application to coupled gas chromatography atomic absorption spectrometry

    Science.gov (United States)

    Johansson, M.; Berglund, M.; Baxter, D. C.

    1993-09-01

    Systematic errors in the measurement of overlapping asymmetric, Chromatographic peaks are observed using the perpendicular-drop and tangent-skimming algorithms incorporated in commercial integrators. The magnitude of such errors increases with the degree of tailing and differences in peak size, and was found to be as great as 80% for peak-area and 100% for peak-height measurements made on the smaller, second component of simulated, noise-free chromatograms containing peaks at a size ratio of 10 to 1. Initial deconvolution of overlapping peaks, by mathematical correction for asymmetry, leads to significant improvements in the accuracy of both peak-area and height measurements using the simple, perpendicular-drop algorithm. A comparison of analytical data for the separation and determination of three organolead species by coupled gas chromatography atomic absorption spectrometry using peak-height and area measurements also demonstrates the improved accuracy obtained following deconvolution. It is concluded that the deconvolution method described could be beneficial in a variety of Chromatographic applications where overlapping, asymmetric peaks are observed.

  12. Size-exclusion simulated moving bed chromatographic protein refolding

    NARCIS (Netherlands)

    Freydell, E.; Bulsink, Y.; Hateren, van S.; Wielen, van der L.; Eppink, M.H.M.; Ottens, M.

    2010-01-01

    Size-exclusion chromatographic refolding (SECR) has successfully proven its capability to refold a variety of proteins using a range of gel filtration column materials. Several approaches have also been undertaken to improve the refolding yield of these systems, mostly under batch operation.

  13. Optimizing Chromatographic Separation: An Experiment Using an HPLC Simulator

    Science.gov (United States)

    Shalliker, R. A.; Kayillo, S.; Dennis, G. R.

    2008-01-01

    Optimization of a chromatographic separation within the time constraints of a laboratory session is practically impossible. However, by employing a HPLC simulator, experiments can be designed that allow students to develop an appreciation of the complexities involved in optimization procedures. In the present exercise, a HPLC simulator from "JCE…

  14. Liquid Chromatographic Determination of Alternaria Toxins in Carrots

    NARCIS (Netherlands)

    Solfrizzo, M.; Girolamo, De A.; Vitti, C.; Bulk, van den R.W.

    2004-01-01

    A liquid chromatographic (LC) method was developed for the determination of Alternaria radicina and A. alternata toxins in carrots. Toxins were extracted from carrot with an acidified mixture of water¿methanol¿acetonitrile. The filtered extract was divided in 2 parts that were purified by

  15. On the ion chromatographic determination of S(IV)

    Science.gov (United States)

    Dasgupta, Purnendu K.

    Ion Chromatographie determination of S(IV) is described with special reference to the determination of SO 2(g) and/or aerosol S(IV) along with chloride, nitrate and sulfate in particulate matter. A method is presented for the baseline separation of the above species. The Chromatographic behavior of hydroxymethanesulfonate under various eluent conditions is discussed.

  16. Chromatographic profiles of Ginkgo biloba leaves and selected products

    Science.gov (United States)

    An LC-DAD-ESI/MS method was developed to obtain chromatographic profiles for the flavonoids and terpene lactones of Ginkgo biloba leaves and selected G. biloba products. The method was used to identify 46 glycosylated flavonols and flavones, 3 free flavonol aglycones, catechin, 10 biflavones, a dihy...

  17. [The gas chromatographic detection of acetylene in cadaveric material].

    Science.gov (United States)

    Iablochkin, V D

    1999-01-01

    Acetylene traces were detected by gas chromatography in the cadaveric right crural muscle of a 30-year-old man dead from an explosion of an acetylene reservoir at a plant. Acetylene was identified using the absolute calibration method on 3 standard gas chromatographic columns, reaction gas chromatography, and acetylene "deduction" by silver sulfate on silicagel.

  18. Note on the chromatographic analyses of marine polyunsaturated fatty acids

    Science.gov (United States)

    Schultz, D.M.; Quinn, J.G.

    1977-01-01

    Gas-liquid chromatography was used to study the effects of saponification/methylation and thin-layer chromatographic isolation on the analyses of polyunsaturated fatty acids. Using selected procedures, the qualitative and quantitative distribution of these acids in marine organisms can be determined with a high degree of accuracy. ?? 1977 Springer-Verlag.

  19. Optimizing Chromatographic Separation: An Experiment Using an HPLC Simulator

    Science.gov (United States)

    Shalliker, R. A.; Kayillo, S.; Dennis, G. R.

    2008-01-01

    Optimization of a chromatographic separation within the time constraints of a laboratory session is practically impossible. However, by employing a HPLC simulator, experiments can be designed that allow students to develop an appreciation of the complexities involved in optimization procedures. In the present exercise, a HPLC simulator from "JCE…

  20. Performance of chromatographic systems to model soil-water sorption.

    Science.gov (United States)

    Hidalgo-Rodríguez, Marta; Fuguet, Elisabet; Ràfols, Clara; Rosés, Martí

    2012-08-24

    A systematic approach for evaluating the goodness of chromatographic systems to model the sorption of neutral organic compounds by soil from water is presented in this work. It is based on the examination of the three sources of error that determine the overall variance obtained when soil-water partition coefficients are correlated against chromatographic retention factors: the variance of the soil-water sorption data, the variance of the chromatographic data, and the variance attributed to the dissimilarity between the two systems. These contributions of variance are easily predicted through the characterization of the systems by the solvation parameter model. According to this method, several chromatographic systems besides the reference octanol-water partition system have been selected to test their performance in the emulation of soil-water sorption. The results from the experimental correlations agree with the predicted variances. The high-performance liquid chromatography system based on an immobilized artificial membrane and the micellar electrokinetic chromatography systems of sodium dodecylsulfate and sodium taurocholate provide the most precise correlation models. They have shown to predict well soil-water sorption coefficients of several tested herbicides. Octanol-water partitions and high-performance liquid chromatography measurements using C18 columns are less suited for the estimation of soil-water partition coefficients.

  1. Partial least squares model and design of experiments toward the analysis of the metabolome of Jatropha gossypifolia leaves: Extraction and chromatographic fingerprint optimization.

    Science.gov (United States)

    Pilon, Alan Cesar; Carnevale Neto, Fausto; Freire, Rafael Teixeira; Cardoso, Patrícia; Carneiro, Renato Lajarim; Da Silva Bolzani, Vanderlan; Castro-Gamboa, Ian

    2016-03-01

    A major challenge in metabolomic studies is how to extract and analyze an entire metabolome. So far, no single method was able to clearly complete this task in an efficient and reproducible way. In this work we proposed a sequential strategy for the extraction and chromatographic separation of metabolites from leaves Jatropha gossypifolia using a design of experiments and partial least square model. The effect of 14 different solvents on extraction process was evaluated and an optimized separation condition on liquid chromatography was estimated considering mobile phase composition and analysis time. The initial conditions of extraction using methanol and separation in 30 min between 5 and 100% water/methanol (1:1 v/v) with 0.1% of acetic acid, 20 μL sample volume, 3.0 mL min(-1) flow rate and 25°C column temperature led to 107 chromatographic peaks. After the optimization strategy using i-propanol/chloroform (1:1 v/v) for extraction, linear gradient elution of 60 min between 5 and 100% water/(acetonitrile/methanol 68:32 v/v with 0.1% of acetic acid), 30 μL sample volume, 2.0 mL min(-1) flow rate, and 30°C column temperature, we detected 140 chromatographic peaks, 30.84% more peaks compared to initial method. This is a reliable strategy using a limited number of experiments for metabolomics protocols.

  2. A novel ion-pairing chromatographic method for the simultaneous determination of both nicarbazin components in feed additives: chemometric tools for improving the optimization and validation.

    Science.gov (United States)

    De Zan, María M; Teglia, Carla M; Robles, Juan C; Goicoechea, Héctor C

    2011-07-15

    The development, optimization and validation of an ion-pairing high performance liquid chromatography method for the simultaneous determination of both nicarbazin (NIC) components: 4,4'-dinitrocarbanilide (DNC) and 2-hydroxy-4,6-dimethylpyrimidine (HDP) in bulk materials and feed additives are described. An experimental design was used for the optimization of the chromatographic system. Four variables, including mobile phase composition and oven temperature, were analyzed through a central composite design exploring their contribution to analyte separation. Five responses: peak resolutions, HDP capacity factor, HDP tailing and analysis time, were modelled by using the response surface methodology and were optimized simultaneously by implementing the desirability function. The optimum conditions resulted in a mobile phase consisting of 10.0 mmol L(-1) of 1-heptanesulfonate, 20.0 mmol L(-1) of sodium acetate, pH=3.30 buffer and acetonitrile in a gradient system at a flow rate of 1.00 mL min(-1). Column was an INERSTIL ODS-3 (4.6 mm×150 mm, 5 μm particle size) at 40.0°C. Detection was performed at 300 nm by a diode array detector. The validation results of the method indicated a high selectivity and good precision characteristics, with RSD less than 1.0% for both components, both in intra and inter-assay precision studies. Linearity was proved for a range of 32.0-50.0 μg mL(-1) of NIC in sample solution. The recovery, studied at three different fortification levels, varied from 98.0 to 101.4 for HDP and from 99.1 to 100.2 for DNC. The applicability of the method was demonstrated by determining DNC and HDP content in raw materials and commercial formulations used for coccidiosis prevention. Assays results on real samples showed that considerable differences in molecular ratio DNC:HDP exist among them.

  3. Climate change and peak demand for electricity: Evaluating policies for reducing peak demand under different climate change scenarios

    Science.gov (United States)

    Anthony, Abigail Walker

    This research focuses on the relative advantages and disadvantages of using price-based and quantity-based controls for electricity markets. It also presents a detailed analysis of one specific approach to quantity based controls: the SmartAC program implemented in Stockton, California. Finally, the research forecasts electricity demand under various climate scenarios, and estimates potential cost savings that could result from a direct quantity control program over the next 50 years in each scenario. The traditional approach to dealing with the problem of peak demand for electricity is to invest in a large stock of excess capital that is rarely used, thereby greatly increasing production costs. Because this approach has proved so expensive, there has been a focus on identifying alternative approaches for dealing with peak demand problems. This research focuses on two approaches: price based approaches, such as real time pricing, and quantity based approaches, whereby the utility directly controls at least some elements of electricity used by consumers. This research suggests that well-designed policies for reducing peak demand might include both price and quantity controls. In theory, sufficiently high peak prices occurring during periods of peak demand and/or low supply can cause the quantity of electricity demanded to decline until demand is in balance with system capacity, potentially reducing the total amount of generation capacity needed to meet demand and helping meet electricity demand at the lowest cost. However, consumers need to be well informed about real-time prices for the pricing strategy to work as well as theory suggests. While this might be an appropriate assumption for large industrial and commercial users who have potentially large economic incentives, there is not yet enough research on whether households will fully understand and respond to real-time prices. Thus, while real-time pricing can be an effective tool for addressing the peak load

  4. Countercurrent chromatographic with upright multilayer coil plante centrifuge for large-scale preparation%一种用于大容量逆流色谱制备的立式多层螺旋管行星式离心机

    Institute of Scientific and Technical Information of China (English)

    吴世华; 孙翠荣; 戴元柏; 周慧; 潘远江; 张虹

    2003-01-01

    Owing to no complications caused by solid supports, such as adsorptive sample loss and deactivation, tailing of solute peaks, and contamination, countercurrent chromatography (CCC) has been an area of intense research since the first introduction of CCC in 1970,[1] and various apparatus and broad applications have been advanced[2,3]. For these developments, the type-J synchronous planet centrifuge has received considerable attention, which relies not only on its relatively simple mechanic design, but also on its high partition efficiency and short elution time caused by mixing and settling for the efficient chromatographic separations. In the past, however, almost all of type-J centrifuges rotated slowly were disposed horizontally due to the original design and some experiments that gravis plays an important role at a low rotary speed as similar to type-V rotating multilayer helical tube in unit gravity[4-9]. In fact,we discovered that the upright apparatus holds more retention of stationary phase than the horiziontal aparatus when large standard tubings were used as mutilayer coil column and the aparatus was operated under same contions. We report here a new coil planet centrifuge with four upright cylindrical columns for large scale countercurrent chromatographic preparation. The design principle and apparatus of UCCC is as samilar to type-J multilayer coil planet centrifuge. Four uptight cylindrical column holders are symmetrically arranged around the centrifuge axis as similar to the type-J HSCCC with three horizontal multilayer coils connected in series[8] . A series of experiments indicat that upright CCC has many advantages over the horizontal CCC when using a large-bore tube as multilayer coil column for large scale countercurrent chromatographic separation.Upright CCC provide a versatile countercurrent chromatographic method for large-scale preparation from very crude sample. It has good preparative capacity and flexible suitability to various sample and

  5. Ion-exchange chromatographic protein refolding.

    Science.gov (United States)

    Freydell, Esteban J; van der Wielen, Luuk; Eppink, Michel; Ottens, Marcel

    2010-11-12

    The application of ion-exchange (IEX) chromatography to protein refolding (IExR) has been successfully proven, as supported by various studies using different model proteins, ion-exchange media and flow configurations. Ion-exchange refolding offers a relatively high degree of process intensification, represented by the possibility of performing protein refolding, product purification and product concentration, in one unit operation. Besides its high degree of process intensification, IExR offers an additional set of key advantages including: spatial isolation of the bound protein molecules and the controllable change in chemical composition using gradients. Despite of the acknowledgement of the former advantages, the lack of mechanistic understanding on how they influence the process performance of the ion-exchange refolding reactor, limits the ability to exploit them in order to optimize the performance of the unit. This paper presents a quantitative analysis that assesses the effect that the spatial isolation and the urea gradient, have on the IExR performance, judged on the basis of the refolding yield (Y(N)) and the fractional mass recovery (f(Prot,Rec)). Additionally, this work discusses the effect of the protein load, the protein loading state (i.e., native, denatured, denatured and reduced (D&R)) and the adsorbent type on f(Prot,Rec). The presented work shows: (1) that the protein load has a direct effect on f(Prot,Rec), and the magnitude of this effect depends on the loading state of the protein solution and the adsorbent type; (2) that irrespectively of the type of adsorbent used, the saturation capacity of a denatured protein is less than the native protein and that this difference can be linked to differences in accessible binding surface area; (3) that there is a clear correlation between fractional surface coverage (θ) and f(Prot,Rec), indicating that the former could serve as a good descriptor to assess spatial isolation, and (4) that the urea

  6. Multivariate data analysis to evaluate the fingerprint peaks responsible for the cytotoxic activity of Mallotus species.

    Science.gov (United States)

    Tistaert, C; Chataigné, G; Dejaegher, B; Rivière, C; Nguyen Hoai, N; Chau Van, M; Quetin-Leclercq, J; Vander Heyden, Y

    2012-12-01

    The Mallotus genus comprises numerous species used as traditional medicines in oriental countries and provides scientists a broad basis in the search for pharmacologically active constituents. In this paper, the cytotoxicity of 39 Mallotus extracts, different in species, part of the plant used, origin, and harvest season, is evaluated combining cytotoxicity assays with fingerprint technology and data handling tools. At first, the antiproliferative activity of the plant extracts is analyzed both on a non-cancerous cell line (WI-38--human lung fibroblast) and on a cancerous cell line (HeLa human cervix carcinoma). The results are linked to a data set of high-performance liquid chromatographic fingerprint profiles of the samples using multivariate calibration techniques. The regression coefficients of the multivariate model are then evaluated to indicate those peaks potentially responsible for the cytotoxic activity of the Mallotus extracts. In a final step, the cytotoxic extracts are analyzed by HPLC-MS and the indicated peaks identified.

  7. The geomorphic structure of the runoff peak

    Directory of Open Access Journals (Sweden)

    R. Rigon

    2011-06-01

    Full Text Available This paper develops a theoretical framework to investigate the core dependence of peak flows on the geomorphic properties of river basins. Based on the theory of transport by travel times, and simple hydrodynamic characterization of floods, this new framework invokes the linearity and invariance of the hydrologic response to provide analytical and semi-analytical expressions for peak flow, time to peak, and area contributing to the peak runoff. These results are obtained for the case of constant-intensity hyetograph using the Intensity-Duration-Frequency (IDF curves to estimate extreme flow values as a function of the rainfall return period. Results show that, with constant-intensity hyetographs, the time-to-peak is greater than rainfall duration and usually shorter than the basin concentration time. Moreover, the critical storm duration is shown to be independent of rainfall return period as well as the area contributing to the flow peak. The same results are found when the effects of hydrodynamic dispersion are accounted for. Further, it is shown that, when the effects of hydrodynamic dispersion are negligible, the basin area contributing to the peak discharge does not depend on the channel velocity, but is a geomorphic propriety of the basin. As an example this framework is applied to three watersheds. In particular, the runoff peak, the critical rainfall durations and the time to peak are calculated for all links within a network to assess how they increase with basin area.

  8. Households’ hourly electricity consumption and peak demand in Denmark

    DEFF Research Database (Denmark)

    Møller Andersen, Frits; Baldini, Mattia; Hansen, Lars Gårn

    2017-01-01

    to a considerable introduction of electric vehicles and individual heat pumps, household consumption is expected to increase considerably, especially peak hour consumption is expected to increase. Next the paper presents results from a new experiment where household customers are given economic and/or environmental......The electrification of residential energy demand for heating and transportation is expected to increase peak load and require additional generation and transmission capacities. Electrification also provides an opportunity to increase demand response. With a focus on household electricity...... incentives to shift consumption to or away from specified hours. The experiment focuses on the present classic consumption and shows that household customers do react to incentives, but today the flexibility of the classic consumption is limited. Considering electric vehicles and individual heat pumps...

  9. Studies on Chromatographic Fingerprint and Fingerprinting Profile-Efficacy Relationship of Saxifraga stolonifera Meerb.

    Directory of Open Access Journals (Sweden)

    Xing-Dong Wu

    2015-12-01

    Full Text Available This work investigated the spectrum-effect relationships between high performance liquid chromatography (HPLC fingerprints and the anti-benign prostatic hyperplasia activities of aqueous extracts from Saxifraga stolonifera. The fingerprints of S. stolonifera from various sources were established by HPLC and evaluated by similarity analysis (SA, hierarchical clustering analysis (HCA and principal component analysis (PCA. Nine samples were obtained from these 24 batches of different origins, according to the results of SA, HCA and the common chromatographic peaks area. A testosterone-induced mouse model of benign prostatic hyperplasia (BPH was used to establish the anti-benign prostatic hyperplasia activities of these nine S. stolonifera samples. The model was evaluated by analyzing prostatic index (PI, serum acid phosphatase (ACP activity, concentrations of serum dihydrotestosterone (DHT, prostatic acid phosphatase (PACP and type II 5α-reductase (SRD5A2. The spectrum-effect relationships between HPLC fingerprints and anti-benign prostatic hyperplasia activities were investigated using Grey Correlation Analysis (GRA and partial least squares regression (PLSR. The results showed that a close correlation existed between the fingerprints and anti-benign prostatic hyperplasia activities, and peak 14 (chlorogenic acid, peak 17 (quercetin 5-O-β-d-glucopyranoside and peak 18 (quercetin 3-O-β-l-rhamno-pyranoside in the HPLC fingerprints might be the main active components against anti-benign prostatic hyperplasia. This work provides a general model for the study of spectrum-effect relationships of S. stolonifera by combing HPLC fingerprints with a testosterone-induced mouse model of BPH, which can be employed to discover the principle components of anti-benign prostatic hyperplasia bioactivity.

  10. Development and Validation of a Stability-Indicating Liquid Chromatographic Method for Estimating Olmesartan Medoxomil Using Quality by Design.

    Science.gov (United States)

    Beg, Sarwar; Sharma, Gajanand; Katare, O P; Lohan, Shikha; Singh, Bhupinder

    2015-08-01

    The current studies entail systematic quality by design (QbD)-based development of a simple, rapid, sensitive and cost-effective stability-indicating method for the estimation of olmesartan medoxomil. Quality target method profile was defined and critical analytical attributes (CAAs) for the reverse-phase liquid chromatography method earmarked. Chromatographic separation accomplished on a C18 column using acetonitrile and water (containing 0.1% orthophosphoric acid, pH 3.5) in 40 : 60 (v/v) as mobile phase at a flow rate of 1.0 mL/min with UV detection at 243 nm. Risk assessment studies and screening studies facilitated comprehensive understanding of the factors affecting CAAs. The mobile phase ratio and flow rate were identified as critical method parameters (CMPs) and were systematically optimized using face-centered cubic design, evaluating for CAAs, namely peak area, retention time, theoretical plates and peak tailing. Statistical modelization was accomplished followed by response surface analysis for comprehending plausible interaction(s) among CMPs. Search for optimum solution was conducted through numerical and graphical optimization for demarcating the design space. Analytical method validation and subsequent forced degradation studies corroborated the method to be highly efficient for routine analysis of drug and its degradation products. The studies successfully demonstrate the utility of QbD approach for developing the highly sensitive liquid chromatographic method with enhanced method performance.

  11. Mountain substitutability and peak load pricing of high alpine peaks as a management tool to reduce environmental damage: a contingent valuation study.

    Science.gov (United States)

    Loomis, John B; Keske, Catherine M

    2009-04-01

    High alpine peaks throughout the world are under increasing environmental pressure from hikers, trekkers, and climbers. Colorado's "Fourteeners", peaks with summits above 14,000 feet are no exception. Most of these peaks have no entrance fees, and reach ecological and social carrying capacity on weekends. This paper illustrates how a series of dichotomous choice contingent valuation questions can be used to evaluate substitutability between different alpine peaks and quantify the price responsiveness to an entrance fee. Using this approach, we find that peak load pricing would decrease use of popular Fourteeners in Colorado by 22%. This reduction is due almost entirely to substitution, rather than income effects. There is also price inelastic demand, as 60% of the hikers find no substitution for their specific Fourteener at the varying cost increases posed in the survey. The no substitute group has a mean net benefit of $294 per hiker, per trip, considerably higher than visitor net benefits in most recreational use studies.

  12. Quality evaluation of Huaijiao pill by chromatographic fingerprint and simultaneous determination of its major bioactive components$

    Institute of Scientific and Technical Information of China (English)

    Shuangqin Wang; Jingjing Zhang; Juan Liu; Guangsheng Qian; Chunmei Fu n

    2016-01-01

    For quality control purpose, an approach of combining chromatographic fingerprint of Huaijiao pill (HP) and simultaneous determination of its major bioactive components was developed using high performance liquid chromatography coupled with diode array detector (HPLC–DAD). For fingerprint analysis, 16 peaks were selected as the characteristic peaks to evaluate the similarities of different samples collected from different batches of three manufacturers. The similarities of 17 Huaijiao pill samples were beyond 0.966, indicating that samples from different batches and manufacturers were, to some extent, consistent. Ad-ditionally, simultaneous quantification of seven bioactive markers, namely sophoricoside, baicalin, nar-ingin, genistein, rutin, quercetin and 5-O-methylvisammioside, in HP was performed to interpret the quality consistency. The validation of the proposed approach was acceptable, with the accuracy of 90.2%–106.9%in recovery test. The intra-day and inter-day precisions of the method were evaluated and the RSD values were less than 2.81%. The results from the quantitative data showed that the contents of six marker compounds (except for 5-O-methylvisammioside) were quite consistent between batches produced by one manufacturer and significantly distinctive among different manufacturers. The proposed approach was expected to be developed as a powerful tool for the quality control of HP.

  13. Quality evaluation of Huaijiao pill by chromatographic fingerprint and simultaneous determination of its major bioactive components

    Directory of Open Access Journals (Sweden)

    Shuangqin Wang

    2016-08-01

    Full Text Available For quality control purpose, an approach of combining chromatographic fingerprint of Huaijiao pill (HP and simultaneous determination of its major bioactive components was developed using high performance liquid chromatography coupled with diode array detector (HPLC--DAD. For fingerprint analysis, 16 peaks were selected as the characteristic peaks to evaluate the similarities of different samples collected from different batches of three manufacturers. The similarities of 17 Huaijiao pill samples were beyond 0.966, indicating that samples from different batches and manufacturers were, to some extent, consistent. Additionally, simultaneous quantification of seven bioactive markers, namely sophoricoside, baicalin, naringin, genistein, rutin, quercetin and 5-O-methylvisammioside, in HP was performed to interpret the quality consistency. The validation of the proposed approach was acceptable, with the accuracy of 90.2%–106.9% in recovery test. The intra-day and inter-day precisions of the method were evaluated and the RSD values were less than 2.81%. The results from the quantitative data showed that the contents of six marker compounds (except for 5-O-methylvisammioside were quite consistent between batches produced by one manufacturer and significantly distinctive among different manufacturers. The proposed approach was expected to be developed as a powerful tool for the quality control of HP.

  14. Purge and trap with monolithic sorbent for gas chromatographic analysis of pesticides in honey.

    Science.gov (United States)

    Chienthavorn, Orapin; Dararuang, Kanittha; Sasook, Anupop; Ramnut, Narumol

    2012-01-01

    Polydivinylbenzene (P-DVB) and silica monolithic materials were synthesised in capillaries and then used to adsorb nine organonitrogen pesticides extracted from honey. After adsorption, each monolith-capillary was connected to a gas chromatograph (GC) with nitrogen-phosphorous detector (NPD). The silica monolith gave better peak shape and intensity than the P-DVB monolith. Formulation of silica monolith with tetramethoxysilane (TMOS) as a sole initiator provided better separation and higher peak intensity, compared to those with methyltrimethoxysilane (MTMS) and (3:1) TMOS/MTMS initiators. The optimum internal diameter and length of silica monolith-capillary were 0.25 mm and 5 cm, respectively. The purge and trap conditions were optimised by purging with nitrogen and heating the honey sample solution at 100 °C for 60 min. Recovery of the method was in a range of 84.95-99.71% and the detection limits of the pesticides determined by using GC-NPD and GC-mass spectrometric detector (MSD) ranged between 0.36-1.75 and 0.13-0.25 ng g(-1), respectively.

  15. Do dark matter halos explain lensing peaks?

    Science.gov (United States)

    Zorrilla Matilla, José Manuel; Haiman, Zoltán; Hsu, Daniel; Gupta, Arushi; Petri, Andrea

    2016-10-01

    We have investigated a recently proposed halo-based model, Camelus, for predicting weak-lensing peak counts, and compared its results over a collection of 162 cosmologies with those from N-body simulations. While counts from both models agree for peaks with S /N >1 (where S /N is the ratio of the peak height to the r.m.s. shape noise), we find ≈50 % fewer counts for peaks near S /N =0 and significantly higher counts in the negative S /N tail. Adding shape noise reduces the differences to within 20% for all cosmologies. We also found larger covariances that are more sensitive to cosmological parameters. As a result, credibility regions in the {Ωm,σ8} are ≈30 % larger. Even though the credible contours are commensurate, each model draws its predictive power from different types of peaks. Low peaks, especially those with 2 important cosmological information in N-body data, as shown in previous studies, but Camelus constrains cosmology almost exclusively from high significance peaks (S /N >3 ). Our results confirm the importance of using a cosmology-dependent covariance with at least a 14% improvement in parameter constraints. We identified the covariance estimation as the main driver behind differences in inference, and suggest possible ways to make Camelus even more useful as a highly accurate peak count emulator.

  16. Capacity Statement for Railways

    DEFF Research Database (Denmark)

    Landex, Alex

    2007-01-01

    The subject “Railway capacity” is a combination of the capacity consumption and how the capacity is utilized. The capacity utilization of railways can be divided into 4 core elements: The number of trains; the average speed; the heterogeneity of the operation; and the stability. This article...... describes how the capacity consumption for railways can be worked out and analytical measurements of how the capacity is utilized. Furthermore, the article describes how it is possible to state and visualize railway capacity. Having unused railway capacity is not always equal to be able to operate more...

  17. The selection of suitable columns for a reversed-phase liquid chromatographic separation of beta-lactam antibiotics and related substances via chromatographic column parameters.

    Science.gov (United States)

    Zhang, Wei-qing; Hu, Qiu-xin; Zhang, Xia; Li, Ya-ping; Wang, Ming-juan; Hu, Chang-qin

    2014-01-01

    The selection of RP-LC columns suitable for a particular analysis in official compendia is difficult as only a general description of the stationary phase in the description of a LC method is given. General methods to characterize RP-LC columns often assume that each of the column parameters is equally important. This can cause the user to select columns inappropriate for particular analyses. This paper focuses on the relationship between the critical peak pairs and the column parameters (H, S, A, B, and C) in the Snyder/Dolan column characterization methodology to find the key parameters influencing real separations. Some varieties of β-lactam antibiotics and their related compounds were used as test compounds. We found column parameter A to be the most important factor affecting their separation. Parameters B and C also played an important role in some separation processes. This indicated that the hydrogen bonding of column and solute can directly affect the separation of β-lactam antibiotics. Choosing columns for which column parameter A is near 0.1 can facilitate the ideal separations of impurities from β-lactam antibiotics. The most suitable column for any common pharmaceutical analysis could be selected easily if the key column parameters would be given in the description of the chromatographic method. For these reasons, key column parameters should be listed in the monographs of official compendia.

  18. Electrocapillary instability of magnetic fluid peak

    CERN Document Server

    Mkrtchyan, Levon; Dikansky, Yuri

    2013-01-01

    The paper presents an experimental study of the capillary electrostatic instability occurring under effect of a constant electric field on a magnetic fluid individual peak. The peaks under study occur at disintegration of a magnetic fluid layer applied on a flat electrode surface under effect of a perpendicular magnetic field. The electrocapillary instability shows itself as an emission of charged drops jets from the peak point in direction of the opposing electrode. The charged drops emission repeats periodically and results in the peak shape pulsations. It is shown that a magnetic field affects the electrocapillary instability occurrence regularities and can stimulate its development. The critical electric and magnetic field strengths at which the instability occurs have been measured; their dependence on the peak size is shown. The hysteresis in the system has been studied; it consists in that the charged drops emission stops at a lesser electric (or magnetic) field strength than that of the initial occurr...

  19. Chiral Ionic Liquids in Chromatographic Separation and Spectroscopic Discrimination

    Science.gov (United States)

    Li, Min; Bwambok, David K.; Fakayode, Sayo O.; Warner, Isiah M.

    Chiral ionic liquids (CILs) are a subclass of ionic liquids (ILs) in which the cation, anion, or both may be chiral. The chirality can be central, axial, or planar. CILs possess a number of unique advantageous properties which are inherited from ionic liquids including negligible vapor pressure, wide liquidus temperature range, high thermal stability, and high tunability. Due to their dual functionalities as chiral selectors and chiral solvents simultaneously, CILs recently have been widely used both in enantiomeric chromatographic separation and in chiral spectroscopic discrimination. In this chapter, the various applications of CILs in chiral chromatographic separations such as GC, HPLC, CE, and MEKC are reviewed. The applications of CILs in enantiomeric spectroscopic discrimination using techniques such as NMR, fluorescence, and NIR are described. In addition, chiral recognition and separation mechanism using the CILs as chiral selectors or chiral solvents is also discussed.

  20. Thin Layer Chromatographic Analysis of Beta-Lactam Antibiotics

    Directory of Open Access Journals (Sweden)

    Gabriel Hancu

    2013-08-01

    Full Text Available Purpose: The paper describes some thin layer chromatographic procedures that allow simple and rapid separation and identification of penicillins and cephalosporins from complex mixtures. Methods: Using silicagel GF254 as stationary phase and selecting different mobile phases we succeeded in the separation of the studied beta-lactamins. Our aim was not only to develop a simple, rapid and efficient method for their separation but also the optimization of the analytical conditions. Results: No system will separate all the beta-lactams, but they could be identified when supplementary information is used from color reactions and/or by using additional chromatographic systems. Conclusions: The right combination of solvent system and detection method allows the identification of the studied penicillins and cephalosporins and can be successfully used in the preliminary analysis beta-lactam antibiotics.

  1. Chiral ionic liquids in chromatographic and electrophoretic separations.

    Science.gov (United States)

    Kapnissi-Christodoulou, Constantina P; Stavrou, Ioannis J; Mavroudi, Maria C

    2014-10-10

    This report provides an overview of the application of chiral ionic liquids (CILs) in separation technology, and particularly in capillary electrophoresis and both gas and liquid chromatography. There is a large number of CILs that have been synthesized and designed as chiral agents. However, only a few have successfully been applied in separation technology. Even though this application of CILs is still in its early stages, the scientific interest is increasing dramatically. This article is focused on the use of CILs as chiral selectors, background electrolyte additives, chiral ligands and chiral stationary phases in electrophoretic and chromatographic techniques. Different examples of CILs, which contain either a chiral cation, a chiral anion or both, are presented in this review article, and their major advantages along with their potential applications in chiral electrophoretic and chromatographic recognition are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Characterization of thermal desorption with the Deans-switch technique in gas chromatographic analysis of volatile organic compounds.

    Science.gov (United States)

    Ou-Yang, Chang-Feng; Huang, Ying-Xue; Huang, Ting-Jyun; Chen, Yong-Shen; Wang, Chieh-Heng; Wang, Jia-Lin

    2016-09-02

    This study presents a novel application based on the Deans-switch cutting technique to characterize the thermal-desorption (TD) properties for gas chromatographic (GC) analysis of ambient volatile organic compounds (VOCs). Flash-heating of the sorbent bed at high temperatures to desorb trapped VOCs to GC may easily produce severe asymmetric or tailing GC peaks affecting resolution and sensitivity if care is not taken to optimize the TD conditions. The TD peak without GC separation was first examined for the quality of the TD peak by analyzing a standard gas mixture from C2 to C12 at ppb level. The Deans switch was later applied in two different stages. First, it was used to cut the trailing tail of the TD peak, which, although significantly improved the GC peak symmetry, led to more loss of the higher boiling compounds than the low boiling ones, thus suggesting compound discrimination. Subsequently, the Deans switch was used to dissect the TD peak into six 30s slices in series, and an uneven distribution in composition between the slices were found. A progressive decrease in low boiling compounds and increase in higher boiling ones across the slices indicated severe inhomogeneity in the TD profile. This finding provided a clear evidence to answer the discrimination problem found with the tail cutting approach to improve peak symmetry. Through the use of the innovated slicing method based on the Deans-switch cutting technique, optimization of TD injection for highly resolved, symmetric and non-discriminated GC peaks can now be more quantitatively assessed and guided.

  3. Metal-Organic Frameworks for Thin-Layer Chromatographic Applications.

    Science.gov (United States)

    Schenk, Claudia; Kutzscher, Christel; Drache, Franziska; Helten, Stella; Senkovska, Irena; Kaskel, Stefan

    2017-01-25

    Preparation of thin-layer chromatographic (TLC) plates based on metal-organic frameworks (MOFs) as porous stationary phases is described. DUT-67 (DUT = Dresden University of Technology), a zirconium based MOF, was used in combination with a fluorescent indicator as stationary phase for analyzing a small selection of a wide spectrum of relevant analytes. The successful separation of benzaldehyde from trans-cinnamaldehyde and 4-aminophenol from 2-aminotoluene is reported as a model system using optimized eluent mixtures containing acetic acid.

  4. Size-exclusion chromatographic NMR under HR-MAS

    OpenAIRE

    Lucena Alcalde, Guillermo; Anderson, Natalie; Day, Iain J.

    2016-01-01

    The addition of stationary phases or sample modifiers can be used to modify the separation achievable in the diffusion domain of diffusion NMR experiments or provide information on the nature of the analyte–sample modifier interaction. Unfortunately, the addition of insoluble chromatographic stationary phases can lead to line broadening and degradation in spectral resolution, largely because of differences in magnetic susceptibility between the sample and the stationary phase. High-resolution...

  5. Can enantiomers be separated in achiral chromatographic systems?

    Science.gov (United States)

    Davankov, V. A.

    2016-10-01

    Consideration of chromatography of a nonracemic mixture on an achiral sorbent from a stereochemical point of view allows the claim that partial separation of the excess enantiomer zone from the racemate zone is possible only with analytes capable of self-associating under the conditions of the chromatographic column. It is from these positions that features of this process can be explained and conditions for its maximal proceeding formulated.

  6. Chromatographic and electrophoretic methods for nanodisc purification and analysis

    DEFF Research Database (Denmark)

    Justesen, Bo Højen; Günther-Pomorski, Thomas

    2014-01-01

    Soluble nanoscale lipid bilayers, termed nanodiscs, are widely used in science for studying the membrane-anchored and integral membrane protein complexes under defined experimental conditions. Although their formation occurs by a self-assembly process, nanodisc purification and the verification...... of proper reconstitution are still major challenges during the sample preparation. This review gives an overview of the methods used for purifying and analyzing nanodiscs and nanodisc-reconstituted membrane proteins, with an emphasis on the chromatographic and electrophoretic approaches....

  7. Chromatographic design for the purification of recombinant human membrane COMT

    OpenAIRE

    Santos, Fátima Raquel Milhano dos

    2012-01-01

    Several studies suggest that membrane form of catechol-O-methyltransferase OMT (MB-COMT) is the main responsible for O-methylation at physiologically low concentrations of catecholamines. Despite this, until now no studies have been allowed the total isolation of MB-COMT. Then, a sustainable chromatographic step should be developed in order to obtain significant quantities of active and pure enzyme for posterior application on biochemical, kinetic and structural studies. For the first time, w...

  8. Rayleigh light scattering detection of three α1-adrenoceptor antagonists coupled with high performance liquid chromatograph

    Science.gov (United States)

    Li, Ai Ping; Peng, Huanjun; Peng, Jing Dong; Zhou, Ming Qiong; Zhang, Jing

    2015-08-01

    Herein, a Rayleigh light-scattering (RLS) detection method combined with high performance liquid chromatograph (HPLC) without any post-column probe was developed for the separation and determination of three α1-adrenoceptor antagonists. The quantitative analysis is benefiting from RLS signal enhancement upon addition of methanol which induced molecular aggregation to form an hydrophobic interface between aggregates and water that produce a sort of superficial enhanced scattering effect. A good chromatographic separation among the compounds was achieved using a Gemini 5u C18 reversed phase column (250 mm × 4.6 mm; 4 μm) with a mobile phase consisting of methanol and ammonium acetate-formic acid buffer solution (25 mM; pH = 3.0) at the flow rate of 0.7 mL min-1. The RLS signal was monitored at λex = λem = 354 nm. A limit of detection (LOD) of 0.065-0.70 μg L-1 was reached and a linear range was found between peak height and concentration in the range of 0.75-15 μg L-1 for doxazosin mesylate (DOX), 0.075-3.0 μg L-1 for prazosin hydrochloride (PRH), and 0.25-5 μg L-1 for terazosin hydrochloride (TEH), with linear regression coefficients all above 0.999. Recoveries from spiked urine samples were 88.4-99.0% which is within acceptable limits. The proposed method is convenient, reliable and sensitive which has been used successfully in human urine samples.

  9. Development of micromachined preconcentrators and gas chromatographic separation columns by an electroless gold plating technology

    Science.gov (United States)

    Kuo, C.-Y.; Chen, P.-S.; Chen, H.-T.; Lu, C.-J.; Tian, W.-C.

    2017-03-01

    In this study, a simple process for fabricating a novel micromachined preconcentrator (μPCT) and a gas chromatographic separation column (μSC) for use in a micro gas chromatograph (μGC) using one photomask is described. By electroless gold plating, a high-surface-area gold layer was deposited on the surface of channels inside the μPCT and μSC. For this process, (3-aminopropyl) trimethoxysilane (APTMS) was used as a promoter for attaching gold nanoparticles on a silicon substrate to create a seed layer. For this purpose, a gold sodium sulfite solution was used as reagent for depositing gold to form heating structures. The microchannels of the μPCT and μSC were coated with the adsorbent and stationary phase, Tenax-TA and polydimethylsiloxane (DB-1), respectively. μPCTs were heated at temperatures greater than 280 °C under an applied electrical power of 24 W and a heating rate of 75 °C s‑1. Repeatable thermal heating responses for μPCTs were achieved; good linearity (R 2  >  0.9997) was attained at three heating rates for the temperature programme for the μSC (0.2, 0.5 and 1 °C s‑1). The volatile organic compounds (VOCs) toluene and m-xylene were concentrated over the μPCT by rapid thermal desorption (peak width of half height (PWHH)  7900. The VOCs acetone, benzene, toluene, m-xylene and 1,3,5-trimethylbenzene were also separated on the μSC as evidenced by their different retention times (47–184 s).

  10. Prediction of Peak Shape and Characterization of Column Performance in Liquid Chromatography as a Function of Flow Rate

    Directory of Open Access Journals (Sweden)

    Juan José Baeza-Baeza

    2015-11-01

    Full Text Available Traditionally, column performance in liquid chromatography has been studied using information from the elution of probe compounds at different flow rates through van Deemter plots, which relate the column plate height to the linear mobile phase velocity. A more recent approach to characterize columns is the representation of the peak widths (or the right and left peak half-widths for a set of compounds versus their retention times, which, for isocratic elution, give rise to almost linear plots. In previous work, these plots have been shown to facilitate the prediction of peak profiles (width and asymmetry with optimization purposes. In this work, a detailed study on the dependence of the peak widths (or half-widths on the flow rate is reported. A new approach to quantify the deterioration of column performance for slow and fast flow rates and to characterize chromatographic columns is proposed. The approach makes use of the width (or half-widths for a set of compounds with similar interaction kinetics and does not require knowledge of the extra-column contributions to the total variance. The chromatographic data of two sets of compounds of different natures (sulfonamides and β-blockers, eluted from Spherisorb and Chromolith columns with acetonitrile-water mixtures, are used to illustrate the approach.

  11. Rapid process development of chromatographic process using direct analysis in real time mass spectrometry as a process analytical technology tool.

    Science.gov (United States)

    Yan, Binjun; Chen, Teng; Xu, Zhilin; Qu, Haibin

    2014-06-01

    The concept of quality by design (QbD) is widely applied in the process development of pharmaceuticals. However, the additional cost and time have caused some resistance about QbD implementation. To show a possible solution, this work proposed a rapid process development method, which used direct analysis in real time mass spectrometry (DART-MS) as a process analytical technology (PAT) tool for studying the chromatographic process of Ginkgo biloba L., as an example. The breakthrough curves were fast determined by DART-MS at-line. A high correlation coefficient of 0.9520 was found between the concentrations of ginkgolide A determined by DART-MS and HPLC. Based on the PAT tool, the impacts of process parameters on the adsorption capacity were discovered rapidly, which showed a decreased adsorption capacity with the increase of the flow rate. This work has shown the feasibility and advantages of integrating PAT into QbD implementation for rapid process development.

  12. Comparative study of Passiflora taxa leaves: II. A chromatographic profile

    Directory of Open Access Journals (Sweden)

    Luma Wosch

    Full Text Available ABSTRACT Popularly known as passion fruit, some species of the genus Passiflora are widely used in folk medicines, such as sedatives and tranquilizers in many countries. Although these plants are employed for the same purposes, research with different species of Passiflora has indicated their heterogeneous chemical compositions. Since different chemical compositions can result in varying degrees of therapeutic efficiency, quality control based on the chemical constituents of each species is essential. To that end, the aim of this study was to compare pharmacognostically species of Passiflora in order to establish a chromatographic profile for the quality control of drugs in herbal medicines containing passion fruit. The study was conducted by collecting samples of leaves from twelve Passiflora taxa (i.e., ten species and two forms of P. edulis – P. actinia, P. alata, P. amethystina, P. capsularis, P. cincinnata, P. edulis f. flavicarpa, P. edulis f. edulis, P. incarnata, P. morifolia, P. urnifolia, P. coccinea, and P. setacea – from different locations and obtaining their chromatographic profiles via thin-layer chromatography and high-performance liquid chromatography. Both methods used the flavonoid C-glycosides isoorientin, orientin, vitexin, and isovitexin as reference compounds and could ultimately establish specific profiles for each species. The chromatographic analyses discussed here can be used to assist in determining the quality and authenticity of herbal drugs derived from Passiflora species.

  13. Studies on improved integrated membrane-based chromatographic process for bioseparation

    Science.gov (United States)

    Xu, Yanke

    To improve protein separation and purification directly from a fermentation broth, a novel membrane filtration-cum-chromatography device configuration having a relatively impermeable coated zone near the hollow fiber module outlet has been developed. The integrated membrane filtration-cum-chromatography unit packed with chromatographic beads on the shell side of the hollow fiber unit enjoys the advantages of both membrane filtration and chromatography; it allows one to load the chromatographic media directly from the fermentation broth or lysate and separate the adsorbed proteins through the subsequent elution step in a cyclic process. Interfacial polymerization was carried out to coat the bottom section of the hollow fiber membrane while leaving the rest of the hollow fiber membrane unaffected. Myoglobin (Mb), bovine serum albumin (BSA) and a-lactalbumin (a-LA) were used as model proteins in binary mixtures. Separation behaviors of binary protein mixtures were studied in devices using either an ultrafiltration (UF) membrane or a microfiltration (MF) membrane. Experimental results show that the breakthrough time and the protein loading capacities were dramatically improved after coating in both UF and MF modules. For a synthetic yeast fermentation broth feed, the Mb and a-LA elution profiles for the four consecutive cyclic runs were almost superimposable. Due to the lower transmembrane flux in this device plus the periodical washing-elution during the chromatographic separation, fouling was not a problem as it is in conventional microfiltration. A mathematical model describing the hydrodynamic and protein loading behaviors of the integrated device using UF membrane with a coated zone was developed. The simulation results for the breakthrough agree well with the experimental breakthrough curves. The optimal length of the coated zone was obtained from the simulation. A theoretical analysis of the protein mass transfer was performed using a diffusion-convection model

  14. The Origin of Weak Lensing Convergence Peaks

    CERN Document Server

    Liu, Jia

    2016-01-01

    Weak lensing convergence peaks are a promising tool to probe nonlinear structure evolution at late times, providing additional cosmological information beyond second-order statistics. Previous theoretical and observational studies have shown that the cosmological constraints on $\\Omega_m$ and $\\sigma_8$ are improved by a factor of up to ~ 2 when peak counts and second-order statistics are combined, compared to using the latter alone. We study the origin of lensing peaks using observational data from the 154 deg$^2$ Canada-France-Hawaii Telescope Lensing Survey. We found that while high peaks (with height $\\kappa$ >3.5 $\\sigma_\\kappa$, where $\\sigma_\\kappa$ is the r.m.s. of the convergence $\\kappa$) are typically due to one single massive halo of ~$10^{15}M_\\odot$, low peaks ($\\kappa$ ~ their virial radii), compared with ~0.25 virial radii for halos linked with high peaks, hinting that low peaks are more immune to baryonic processes whose impact is confined to the inner regions of the dark matter halos. Our fi...

  15. Development of Chromatographic Fingerprints of Eurycoma longifolia (Tongkat Ali) Roots Using Online Solid Phase Extraction-Liquid Chromatography (SPE-LC).

    Science.gov (United States)

    Zaini, Nor Nasriah; Osman, Rozita; Juahir, Hafizan; Saim, Norashikin

    2016-04-30

    E. longifolia is attracting interest due to its pharmacological properties and pro-vitality effects. In this study, an online SPE-LC approach using polystyrene divinyl benzene (PSDVB) and C18 columns was developed in obtaining chromatographic fingerprints of E. longifolia. E. longifolia root samples were extracted using pressurized liquid extraction (PLE) technique prior to online SPE-LC. The effects of mobile phase compositions and column switching time on the chromatographic fingerprint were optimized. Validation of the developed method was studied based on eurycomanone. Linearity was in the range of 5 to 50 µg∙mL(-1) (r² = 0.997) with 3.2% relative standard deviation of peak area. The developed method was used to analyze 14 E. longifolia root samples and 10 products (capsules). Selected chemometric techniques: cluster analysis (CA), discriminant analysis (DA), and principal component analysis (PCA) were applied to the fingerprint datasets of 37 selected peaks to evaluate the ability of the chromatographic fingerprint in classifying quality of E. longifolia. Three groups were obtained using CA. DA yielded 100% correlation coefficient with 19 discriminant compounds. Using PCA, E. longifolia root samples were clearly discriminated from the products. This study showed that the developed online SPE-LC method was able to provide comprehensive evaluation of E. longifolia samples for quality control purposes.

  16. Development of Chromatographic Fingerprints of Eurycoma longifolia (Tongkat Ali Roots Using Online Solid Phase Extraction-Liquid Chromatography (SPE-LC

    Directory of Open Access Journals (Sweden)

    Nor Nasriah Zaini

    2016-04-01

    Full Text Available E. longifolia is attracting interest due to its pharmacological properties and pro-vitality effects. In this study, an online SPE-LC approach using polystyrene divinyl benzene (PSDVB and C18 columns was developed in obtaining chromatographic fingerprints of E. longifolia. E. longifolia root samples were extracted using pressurized liquid extraction (PLE technique prior to online SPE-LC. The effects of mobile phase compositions and column switching time on the chromatographic fingerprint were optimized. Validation of the developed method was studied based on eurycomanone. Linearity was in the range of 5 to 50 µg∙mL−1 (r2 = 0.997 with 3.2% relative standard deviation of peak area. The developed method was used to analyze 14 E. longifolia root samples and 10 products (capsules. Selected chemometric techniques: cluster analysis (CA, discriminant analysis (DA, and principal component analysis (PCA were applied to the fingerprint datasets of 37 selected peaks to evaluate the ability of the chromatographic fingerprint in classifying quality of E. longifolia. Three groups were obtained using CA. DA yielded 100% correlation coefficient with 19 discriminant compounds. Using PCA, E. longifolia root samples were clearly discriminated from the products. This study showed that the developed online SPE-LC method was able to provide comprehensive evaluation of E. longifolia samples for quality control purposes.

  17. Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

    Science.gov (United States)

    Huz, Kateryna

    2014-01-01

    RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better

  18. Low-SNR Capacity of MIMO Optical Intensity Channels

    KAUST Repository

    Chaaban, Anas

    2017-09-18

    The capacity of the multiple-input multiple-output (MIMO) optical intensity channel is studied, under both average and peak intensity constraints. We focus on low SNR, which can be modeled as the scenario where both constraints proportionally vanish, or where the peak constraint is held constant while the average constraint vanishes. A capacity upper bound is derived, and is shown to be tight at low SNR under both scenarios. The capacity achieving input distribution at low SNR is shown to be a maximally-correlated vector-binary input distribution. Consequently, the low-SNR capacity of the channel is characterized. As a byproduct, it is shown that for a channel with peak intensity constraints only, or with peak intensity constraints and individual (per aperture) average intensity constraints, a simple scheme composed of coded on-off keying, spatial repetition, and maximum-ratio combining is optimal at low SNR.

  19. Peak load arrangements : Assessment of Nordel guidelines

    Energy Technology Data Exchange (ETDEWEB)

    2009-07-01

    Two Nordic countries, Sweden and Finland, have legislation that empowers the TSO to acquire designated peak load resources to mitigate the risk for shortage situations during the winter. In Denmark, the system operator procures resources to maintain a satisfactory level of security of supply. In Norway the TSO has set up a Regulation Power Option Market (RKOM) to secure a satisfactory level of operational reserves at all times, also in winter with high load demand. Only the arrangements in Finland and Sweden fall under the heading of Peak Load Arrangements defined in Nordel Guidelines. NordREG has been invited by the Electricity Market Group (EMG) to evaluate Nordel's proposal for 'Guidelines for transitional Peak Load Arrangements'. The EMG has also financed a study made by EC Group to support NordREG in the evaluation of the proposal. The study has been taken into account in NordREG's evaluation. In parallel to the EMG task, the Swedish regulator, the Energy Markets Inspectorate, has been given the task by the Swedish government to investigate a long term solution of the peak load issue. The Swedish and Finnish TSOs have together with Nord Pool Spot worked on finding a harmonized solution for activation of the peak load reserves in the market. An agreement accepted by the relevant authorities was reached in early January 2009, and the arrangement has been implemented since 19th January 2009. NordREG views that the proposed Nordel guidelines have served as a starting point for the presently agreed procedure. However, NordREG does not see any need to further develop the Nordel guidelines for peak load arrangements. NordREG agrees with Nordel that the market should be designed to solve peak load problems through proper incentives to market players. NordREG presumes that the relevant authorities in each country will take decisions on the need for any peak load arrangement to ensure security of supply. NordREG proposes that such decisions should be

  20. Bayesian peak picking for NMR spectra.

    Science.gov (United States)

    Cheng, Yichen; Gao, Xin; Liang, Faming

    2014-02-01

    Protein structure determination is a very important topic in structural genomics, which helps people to understand varieties of biological functions such as protein-protein interactions, protein-DNA interactions and so on. Nowadays, nuclear magnetic resonance (NMR) has often been used to determine the three-dimensional structures of protein in vivo. This study aims to automate the peak picking step, the most important and tricky step in NMR structure determination. We propose to model the NMR spectrum by a mixture of bivariate Gaussian densities and use the stochastic approximation Monte Carlo algorithm as the computational tool to solve the problem. Under the Bayesian framework, the peak picking problem is casted as a variable selection problem. The proposed method can automatically distinguish true peaks from false ones without preprocessing the data. To the best of our knowledge, this is the first effort in the literature that tackles the peak picking problem for NMR spectrum data using Bayesian method.

  1. Osteoporosis: Peak Bone Mass in Women

    Science.gov (United States)

    ... not supported by your browser. Home Osteoporosis Women Osteoporosis: Peak Bone Mass in Women Publication available in: ... drug products. NIH Pub. No. 15-7891 NIH Osteoporosis and Related Bone Diseases ~ National Resource Center 2 ...

  2. Bayesian Peak Picking for NMR Spectra

    KAUST Repository

    Cheng, Yichen

    2014-02-01

    Protein structure determination is a very important topic in structural genomics, which helps people to understand varieties of biological functions such as protein-protein interactions, protein–DNA interactions and so on. Nowadays, nuclear magnetic resonance (NMR) has often been used to determine the three-dimensional structures of protein in vivo. This study aims to automate the peak picking step, the most important and tricky step in NMR structure determination. We propose to model the NMR spectrum by a mixture of bivariate Gaussian densities and use the stochastic approximation Monte Carlo algorithm as the computational tool to solve the problem. Under the Bayesian framework, the peak picking problem is casted as a variable selection problem. The proposed method can automatically distinguish true peaks from false ones without preprocessing the data. To the best of our knowledge, this is the first effort in the literature that tackles the peak picking problem for NMR spectrum data using Bayesian method.

  3. Amplification of postwildfire peak flow by debris

    Science.gov (United States)

    Kean, J. W.; McGuire, L. A.; Rengers, F. K.; Smith, J. B.; Staley, D. M.

    2016-08-01

    In burned steeplands, the peak depth and discharge of postwildfire runoff can substantially increase from the addition of debris. Yet methods to estimate the increase over water flow are lacking. We quantified the potential amplification of peak stage and discharge using video observations of postwildfire runoff, compiled data on postwildfire peak flow (Qp), and a physically based model. Comparison of flood and debris flow data with similar distributions in drainage area (A) and rainfall intensity (I) showed that the median runoff coefficient (C = Qp/AI) of debris flows is 50 times greater than that of floods. The striking increase in Qp can be explained using a fully predictive model that describes the additional flow resistance caused by the emergence of coarse-grained surge fronts. The model provides estimates of the amplification of peak depth, discharge, and shear stress needed for assessing postwildfire hazards and constraining models of bedrock incision.

  4. Peak Vegetation Growth 2000 - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer is a grid map of 2000 peak vegetation growth for Alaska and the conterminous United States. The nominal spatial resolution is 1 kilometer and the map...

  5. Peak Vegetation Growth 2004 - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer is a grid map of 2004 peak vegetation growth for Alaska and the conterminous United States. The nominal spatial resolution is 1 kilometer and the map...

  6. Peak Vegetation Growth 1999 - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer is a grid map of 1999 peak vegetation growth for Alaska and the conterminous United States. The nominal spatial resolution is 1 kilometer and the map...

  7. Peak Vegetation Growth 1993 - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer is a grid map of 1993 peak vegetation growth for Alaska and the conterminous United States. The nominal spatial resolution is 1 kilometer and the map...

  8. Peak Vegetation Growth 1994 - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer is a grid map of 1994 peak vegetation growth for Alaska and the conterminous United States. The nominal spatial resolution is 1 kilometer and the map...

  9. Peak Vegetation Growth 1995 - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer is a grid map of 1995 peak vegetation growth for Alaska and the conterminous United States. The nominal spatial resolution is 1 kilometer and the map...

  10. Peak Vegetation Growth 1998 - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer is a grid map of 1998 peak vegetation growth for Alaska and the conterminous United States. The nominal spatial resolution is 1 kilometer and the map...

  11. Peak Vegetation Growth 2001 - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer is a grid map of 2001 peak vegetation growth for Alaska and the conterminous United States. The nominal spatial resolution is 1 kilometer and the map...

  12. Peak Vegetation Growth 2003 - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer is a grid map of 2003 peak vegetation growth for Alaska and the conterminous United States. The nominal spatial resolution is 1 kilometer and the map...

  13. Peak Vegetation Growth 1997 - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer is a grid map of 1997 peak vegetation growth for Alaska and the conterminous United States. The nominal spatial resolution is 1 kilometer and the map...

  14. Peak Vegetation Growth 1990 - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer is a grid map of 1990 peak vegetation growth for Alaska and the conterminous United States. The nominal spatial resolution is 1 kilometer and the map...

  15. Peak Vegetation Growth 1996 - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer is a grid map of 1996 peak vegetation growth for Alaska and the conterminous United States. The nominal spatial resolution is 1 kilometer and the map...

  16. Peak Vegetation Growth 2005 - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer is a grid map of 2005 peak vegetation growth for Alaska and the conterminous United States. The nominal spatial resolution is 1 kilometer and the map...

  17. Tectonics, Climate and Earth's highest peaks

    Science.gov (United States)

    Robl, Jörg; Prasicek, Günther; Hergarten, Stefan

    2016-04-01

    Prominent peaks characterized by high relief and steep slopes are among the most spectacular morphological features on Earth. In collisional orogens they result from the interplay of tectonically driven crustal thickening and climatically induced destruction of overthickened crust by erosional surface processes. The glacial buzz-saw hypothesis proposes a superior status of climate in limiting mountain relief and peak altitude due to glacial erosion. It implies that peak altitude declines with duration of glacial occupation, i.e., towards high latitudes. This is in strong contrast with high peaks existing in high latitude mountain ranges (e.g. Mt. St. Elias range) and the idea of peak uplift due to isostatic compensation of spatially variable erosional unloading an over-thickened orogenic crust. In this study we investigate landscape dissection, crustal thickness and vertical strain rates in tectonically active mountain ranges to evaluate the influence of erosion on (latitudinal) variations in peak altitude. We analyze the spatial distribution of serval thousand prominent peaks on Earth extracted from the global ETOPO1 digital elevation model with a novel numerical tool. We compare this dataset to crustal thickness, thickening rate (vertical strain rate) and mean elevation. We use the ratios of mean elevation to peak elevation (landscape dissection) and peak elevation to crustal thickness (long-term impact of erosion on crustal thickness) as indicators for the influence of erosional surface processes on peak uplift and the vertical strain rate as a proxy for the mechanical state of the orogen. Our analysis reveals that crustal thickness and peak elevation correlate well in orogens that have reached a mechanically limited state (vertical strain rate near zero) where plate convergence is already balanced by lateral extrusion and gravitational collapse and plateaus are formed. On the Tibetan Plateau crustal thickness serves to predict peak elevation up to an altitude

  18. Cosmic Microwave Background Acoustic Peak Locations

    CERN Document Server

    Pan, Zhen; Mulroe, Brigid; Narimani, Ali

    2016-01-01

    The Planck collaboration has measured the temperature and polarization of the cosmic microwave background well enough to determine the locations of eight peaks in the temperature (TT) power spectrum, five peaks in the polarization (EE) power spectrum and twelve extrema in the cross (TE) power spectrum. The relative locations of these extrema give a striking, and beautiful, demonstration of what we expect from acoustic oscillations in the plasma; e.g., that EE peaks fall half way between TT peaks. We expect this because the temperature map is predominantly sourced by temperature variations in the last scattering surface, while the polarization map is predominantly sourced by gradients in the velocity field, and the harmonic oscillations have temperature and velocity 90 degrees out of phase. However, there are large differences in expectations for extrema locations from simple analytic models vs. numerical calculations. Here we quantitatively explore the origin of these differences in gravitational potential tr...

  19. A dynamic programming approach for the alignment of signal peaks in multiple gas chromatography-mass spectrometry experiments

    Directory of Open Access Journals (Sweden)

    McConville Malcolm J

    2007-10-01

    Full Text Available Abstract Background Gas chromatography-mass spectrometry (GC-MS is a robust platform for the profiling of certain classes of small molecules in biological samples. When multiple samples are profiled, including replicates of the same sample and/or different sample states, one needs to account for retention time drifts between experiments. This can be achieved either by the alignment of chromatographic profiles prior to peak detection, or by matching signal peaks after they have been extracted from chromatogram data matrices. Automated retention time correction is particularly important in non-targeted profiling studies. Results A new approach for matching signal peaks based on dynamic programming is presented. The proposed approach relies on both peak retention times and mass spectra. The alignment of more than two peak lists involves three steps: (1 all possible pairs of peak lists are aligned, and similarity of each pair of peak lists is estimated; (2 the guide tree is built based on the similarity between the peak lists; (3 peak lists are progressively aligned starting with the two most similar peak lists, following the guide tree until all peak lists are exhausted. When two or more experiments are performed on different sample states and each consisting of multiple replicates, peak lists within each set of replicate experiments are aligned first (within-state alignment, and subsequently the resulting alignments are aligned themselves (between-state alignment. When more than two sets of replicate experiments are present, the between-state alignment also employs the guide tree. We demonstrate the usefulness of this approach on GC-MS metabolic profiling experiments acquired on wild-type and mutant Leishmania mexicana parasites. Conclusion We propose a progressive method to match signal peaks across multiple GC-MS experiments based on dynamic programming. A sensitive peak similarity function is proposed to balance peak retention time and peak

  20. Do dark matter halos explain lensing peaks?

    CERN Document Server

    Matilla, José Manuel Zorrilla; Hsu, Daniel; Gupta, Arushi; Petri, Andrea

    2016-01-01

    We have investigated a recently proposed halo-based model, Camelus, for predicting weak-lensing peak counts, and compared its results over a collection of 162 cosmologies with those from N-body simulations. While counts from both models agree for peaks with $\\mathcal{S/N}>1$ (where $\\mathcal{S/N}$ is the ratio of the peak height to the r.m.s. shape noise), we find $\\approx 50\\%$ fewer counts for peaks near $\\mathcal{S/N}=0$ and significantly higher counts in the negative $\\mathcal{S/N}$ tail. Adding shape noise reduces the differences to within $20\\%$ for all cosmologies. We also found larger covariances that are more sensitive to cosmological parameters. As a result, credibility regions in the $\\{\\Omega_m, \\sigma_8\\}$ are $\\approx 30\\%$ larger. Even though the credible contours are commensurate, each model draws its predictive power from different types of peaks. Low peaks, especially those with $23)$. Our results confirm the importance of using a cosmology-dependent covariance with at least a 14\\% improveme...

  1. Wingate Anaerobic Test Peak Power and Anaerobic Capacity Classification for Men and Women Intercollegiate Athletes

    Science.gov (United States)

    2009-12-01

    Ponorac et al. (1 7) Sbriccol i et al. Starling et al. (20) Watson and Sargeant (22) Weber et al. (23) Wiegman et al. (24) 2008 2001 2004 2002 2007 1 998... Wiegman , JE Burton, RR, and Forster, EM. The role of anaerobic power in human tolerance to simulated aerial combat maneuvers. Aotat Span Emimn Med 66

  2. Discontinuous symplectic capacities

    NARCIS (Netherlands)

    Zehmisch, K.; Ziltener, F.J.

    2014-01-01

    We show that the spherical capacity is discontinuous on a smooth family of ellipsoidal shells. Moreover, we prove that the shell capacity is discontinuous on a family of open sets with smooth connected boundaries.

  3. New liquid chromatographic-chemometric approach for the determination of sunset yellow and tartrazine in commercial preparation.

    Science.gov (United States)

    Dinç, Erdal; Aktaş, A Hakan; Ustündağ, Ozgür

    2005-01-01

    A new liquid chromatographic (LC)-chemometric approach was developed for the determination of sunset yellow (SUN) and tartrazine (TAR) in commercial preparations. This approach uses LC and chemometric calibration methods, i.e., classical least-squares (CLS), principal component regression (PCR), and partial-least squares (PLS), simultaneously. The combined LC-chemometric approaches, denoted as LC-CLS, LC-PCR, and LC-PLS, are based on photodiode array (PDA) detection at multiple wavelengths. Optimum chromatographic separation of SUN and TAR with allura red as the internal standard (IS) was obtained by using a Waters Symmetry C18 column, 5 microm, 4.6 x 250 mm, and 0.2 M acetate buffer (pH 5)-acetonitrile-methano-bidistilled water (55 + 20 + 15 + 10, v/v) as the mobile phase at a flow rate of 1.9 mL/min. The LC data sets consisting of the ratios of analyte peak areas to the IS peak area were obtained by using PDA detection at 5 wavelengths (465, 470, 475, 480, and 485 nm). LC-chemometric calibrations for SUN and TAR were separately constructed by using the relationship between the peak-area ratio and the training sets for each colorant. LC-chemometric approaches were tested for different synthetic mixtures containing SUN and TAR in the presence of the IS. These LC-chemometric calibrations were applied to a commercial preparation of the 2 colorants. The experimental results of the LC-chemometric approaches were compared with those obtained by a developed classical LC method using single-wavelength detection.

  4. Responsibility and Capacities

    DEFF Research Database (Denmark)

    Ryberg, Jesper

    2014-01-01

    That responsible moral agency presupposes certain mental capacities, constitutes a widely accepted view among theorists. Moreover, it is often assumed that degrees in the development of the relevant capacities co-vary with degrees of responsibility. In this article it is argued that, the move from...... the view that responsibility requires certain mental capacities to the position that degrees of responsibility co-vary with degrees of the development of the mental capacities, is premature....

  5. High-Throughput Analysis of Methylmalonic Acid in Serum, Plasma, and Urine by LC-MS/MS. Method for Analyzing Isomers Without Chromatographic Separation.

    Science.gov (United States)

    Kushnir, Mark M; Nelson, Gordon J; Frank, Elizabeth L; Rockwood, Alan L

    2016-01-01

    Measurement of methylmalonic acid (MMA) plays an important role in the diagnosis of vitamin B12 deficiency. Vitamin B12 is an essential cofactor for the enzymatic carbon rearrangement of methylmalonyl-CoA (MMA-CoA) to succinyl-CoA (SA-CoA), and the lack of vitamin B12 leads to elevated concentrations of MMA. Presence of succinic acid (SA) complicates the analysis because mass spectra of MMA and SA are indistinguishable, when analyzed in negative ion mode and the peaks are difficult to resolve chromatographically. We developed a method for the selective analysis of MMA that exploits the significant difference in fragmentation patterns of di-butyl derivatives of the isomers MMA and SA in a tandem mass spectrometer when analyzed in positive ion mode. Tandem mass spectra of di-butyl derivatives of MMA and SA are very distinct; this allows selective analysis of MMA in the presence of SA. The instrumental analysis is performed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in positive ion mode, which is, in combination with selective extraction of acidic compounds, is highly selective for organic acids with multiple carboxyl groups (dicarboxylic, tricarboxylic, etc.). In this method organic acids with a single carboxyl group are virtually undetectable in the mass spectrometer; the only organic acid, other than MMA, that is detected by this method is its isomer, SA. Quantitative measurement of MMA in this method is performed using a deconvolution algorithm, which mathematically resolves the signal corresponding to MMA and does not require chromatographic resolution of the MMA and SA peaks. Because of its high selectivity, the method utilizes isocratic chromatographic separation; reconditioning and re-equilibration of the chromatographic column between injections is unnecessary. The above features of the method allow high-throughput analysis of MMA with analysis cycle time of 1 min.

  6. CDMA systems capacity engineering

    CERN Document Server

    Kim, Kiseon

    2004-01-01

    This new hands-on resource tackles capacity planning and engineering issues that are crucial to optimizing wireless communication systems performance. Going beyond the system physical level and investigating CDMA system capacity at the service level, this volume is the single-source for engineering and analyzing systems capacity and resources.

  7. A validated stability-indicating liquid chromatographic method for the determination of retapamulin in topical dosage form.

    Science.gov (United States)

    Nalwade, Santaji; Reddy, Vangala Ranga

    2014-03-01

    A sensitive, stability-indicating reversed-phase high-performance liquid chromatographic method is developed and validated for the quantitative determination of retapamulin in topical dosage form. The chromatographic separation is achieved by using a C18 column (XTerra RP 18 250 × 4.6 mm, 5 µm) at 30°C. The mobile phase comprises a mixture of 0.05M potassium dihydrogen phosphate buffer (pH 6.1), acetonitrile and methanol in the ratio of 35:50:15 (v/v/v). The flow rate is set at 1.0 mL/min and chromatograms are extracted at 243 nm using a photodiode array detector. The method is validated with respect to linearity, accuracy, precision, robustness and forced degradation studies, which further prove the stability-indicating supremacy of the method. During forced degradation studies, retapamulin is observed to be labile to oxidative and base hydrolysis stress and stable in thermal, photolytic and acid hydrolysis stress. The degradation products are well separated from the retapamulin peak, thus proving the stability-indicating superiority of the method. The method is found to be sensitive for retapamulin, with a detection limit of 25 ng/mL and a quantification limit of 80 ng/mL. The proposed method is found to be very sensitive and accurate for the determination of retapamulin in topical dosage form. The method is also demonstrated to be robust, because it is resistant to small variations of chromatographic variables such as pH, mobile phase composition, flow rate and column temperature.

  8. Development of visual peak selection system based on multi-ISs normalization algorithm to apply to methamphetamine impurity profiling.

    Science.gov (United States)

    Lee, Hun Joo; Han, Eunyoung; Lee, Jaesin; Chung, Heesun; Min, Sung-Gi

    2016-11-01

    The aim of this study is to improve resolution of impurity peaks using a newly devised normalization algorithm for multi-internal standards (ISs) and to describe a visual peak selection system (VPSS) for efficient support of impurity profiling. Drug trafficking routes, location of manufacture, or synthetic route can be identified from impurities in seized drugs. In the analysis of impurities, different chromatogram profiles are obtained from gas chromatography and used to examine similarities between drug samples. The data processing method using relative retention time (RRT) calculated by a single internal standard is not preferred when many internal standards are used and many chromatographic peaks present because of the risk of overlapping between peaks and difficulty in classifying impurities. In this study, impurities in methamphetamine (MA) were extracted by liquid-liquid extraction (LLE) method using ethylacetate containing 4 internal standards and analyzed by gas chromatography-flame ionization detection (GC-FID). The newly developed VPSS consists of an input module, a conversion module, and a detection module. The input module imports chromatograms collected from GC and performs preprocessing, which is converted with a normalization algorithm in the conversion module, and finally the detection module detects the impurities in MA samples using a visualized zoning user interface. The normalization algorithm in the conversion module was used to convert the raw data from GC-FID. The VPSS with the built-in normalization algorithm can effectively detect different impurities in samples even in complex matrices and has high resolution keeping the time sequence of chromatographic peaks the same as that of the RRT method. The system can widen a full range of chromatograms so that the peaks of impurities were better aligned for easy separation and classification. The resolution, accuracy, and speed of impurity profiling showed remarkable improvement. Copyright

  9. Five-descriptor model to predict the chromatographic sequence of natural compounds.

    Science.gov (United States)

    Hou, Shuying; Wang, Jinhua; Li, Zhangming; Wang, Yang; Wang, Ying; Yang, Songling; Xu, Jia; Zhu, Wenliang

    2016-03-01

    Despite the recent introduction of mass detection techniques, ultraviolet detection is still widely applied in the field of the chromatographic analysis of natural medicines. Here, a neural network cascade model consisting of nine small artificial neural network units was innovatively developed to predict the chromatographic sequence of natural compounds by integrating five molecular descriptors as the input. A total of 117 compounds of known structure were collected for model building. The order of appearance of each compound was determined in gradient chromatography. Strong linear correlation was found between the predicted and actual chromatographic position orders (Spearman's rho = 0.883, p chromatographic order of multiple compounds. A case study shows that chromatographic sequence prediction based on a neural network cascade facilitated compound identification in the chromatographic fingerprint of Radix Salvia miltiorrhiza. For natural medicines of known compound composition, our method provides a feasible means for identifying the constituents of interest when only ultraviolet detection is available.

  10. Temperature dependence of electronic heat capacity in Holstein model

    CERN Document Server

    Fialko, N S; Lakhno, V D

    2015-01-01

    The dynamics of charge migration was modeled to calculate temperature dependencies of its thermodynamic equilibrium values such as energy and electronic heat capacity in homogeneous adenine fragments. The energy varies from nearly polaron one at T~0 to midpoint of the conductivity band at high temperatures. The peak on the graph of electronic heat capacity is observed at the polaron decay temperature.

  11. Chromatographic separation of bioactive oxycholesterols by GC, HPLC and SFC.

    Science.gov (United States)

    McAllister, Heather; Wu, Jiejun

    2012-01-01

    In this paper we report the development of chromatographic methods for the separation of 8 biologically active hydroxycholesterols (OHC's) which include the single-hydroxyl addition species 7α-OHC, 7β-OHC, 25-OHC and 27- OHC, together with the double-hydroxyl addition species 7α, 25-OHC, 7β, 25-OHC, 7α, 27-OHC, and 7β, 27-OHC. Four complementary techniques were employed (gas chromatography, normal phase and reversed phase high performance liquid chromatography, and supercritical fluid chromatography), and for each of the techniques, an optimized method for the separation of all eight compounds in a mixture is presented.

  12. Representation of Solar Capacity Value in the ReEDS Capacity Expansion Model

    Energy Technology Data Exchange (ETDEWEB)

    Sigrin, B.; Sullivan, P.; Ibanez, E.; Margolis, R.

    2014-03-01

    An important issue for electricity system operators is the estimation of renewables' capacity contributions to reliably meeting system demand, or their capacity value. While the capacity value of thermal generation can be estimated easily, assessment of wind and solar requires a more nuanced approach due to the resource variability. Reliability-based methods, particularly assessment of the Effective Load-Carrying Capacity, are considered to be the most robust and widely-accepted techniques for addressing this resource variability. This report compares estimates of solar PV capacity value by the Regional Energy Deployment System (ReEDS) capacity expansion model against two sources. The first comparison is against values published by utilities or other entities for known electrical systems at existing solar penetration levels. The second comparison is against a time-series ELCC simulation tool for high renewable penetration scenarios in the Western Interconnection. Results from the ReEDS model are found to compare well with both comparisons, despite being resolved at a super-hourly temporal resolution. Two results are relevant for other capacity-based models that use a super-hourly resolution to model solar capacity value. First, solar capacity value should not be parameterized as a static value, but must decay with increasing penetration. This is because -- for an afternoon-peaking system -- as solar penetration increases, the system's peak net load shifts to later in the day -- when solar output is lower. Second, long-term planning models should determine system adequacy requirements in each time period in order to approximate LOLP calculations. Within the ReEDS model we resolve these issues by using a capacity value estimate that varies by time-slice. Within each time period the net load and shadow price on ReEDS's planning reserve constraint signals the relative importance of additional firm capacity.

  13. Temperature Control of Gas Chromatograph Based on Switched Delayed System Techniques

    Directory of Open Access Journals (Sweden)

    Xiao-Liang Wang

    2014-01-01

    Full Text Available We address the temperature control problem of the gas chromatograph. We model the temperature control system of the gas chromatograph into a switched delayed system and analyze the stability by common Lyapunov functional technique. The PI controller parameters can be given based on the proposed linear matrix inequalities (LMIs condition and the designed controller can make the temperature of gas chromatograph track the reference signal asymptotically. An experiment is given to illustrate the effectiveness of the stability criterion.

  14. Capacity Bounds for Parallel Optical Wireless Channels

    KAUST Repository

    Chaaban, Anas

    2016-01-01

    A system consisting of parallel optical wireless channels with a total average intensity constraint is studied. Capacity upper and lower bounds for this system are derived. Under perfect channel-state information at the transmitter (CSIT), the bounds have to be optimized with respect to the power allocation over the parallel channels. The optimization of the lower bound is non-convex, however, the KKT conditions can be used to find a list of possible solutions one of which is optimal. The optimal solution can then be found by an exhaustive search algorithm, which is computationally expensive. To overcome this, we propose low-complexity power allocation algorithms which are nearly optimal. The optimized capacity lower bound nearly coincides with the capacity at high SNR. Without CSIT, our capacity bounds lead to upper and lower bounds on the outage probability. The outage probability bounds meet at high SNR. The system with average and peak intensity constraints is also discussed.

  15. Chromatographic characterisation, under highly aqueous conditions, of a molecularly imprinted polymer binding the herbicide 2,4-dichlorophenoxyacetic acid.

    Science.gov (United States)

    Legido-Quigley, C; Oxelbark, J; De Lorenzi, E; Zurutuza-Elorza, A; Cormack, P A G

    2007-05-15

    The affinity of a 2,4-dichlorophenoxyacetic acid (2,4-D) molecularly imprinted polymer (MIP), which was synthesised directly in an aqueous organic solvent, for its template (2,4-D) was studied and compared with the affinity exhibited by two other reference (control) polymers, NIPA and NIPB, for the same analyte. Zonal chromatography was performed to establish the optimal selectivity, expressed as imprinting factor (IF), under chromatographic conditions more aqueous than those described so far in the literature. Frontal analysis (FA) was performed on columns packed with these polymers, using an optimized mobile phase composed of methanol/phosphate buffer (50/50, v/v), to extract adsorption isotherm data and retrieve binding parameters from the best isotherm model. Surprisingly, the template had comparable and strong affinity for both MIP (K = 3.8x10(4) M(-1)) and NIPA (K = 1.9x10(4) M(-1)), although there was a marked difference in the saturation capacities of selective and non-selective sites, as one would expect for an imprinted polymer. NIPB acts as a true control polymer in the sense that it has relatively low affinity for the template (K = 8.0x10(2) M(-1)). This work provides the first frontal chromatographic characterization of such a polymer in a water-rich environment over a wide concentration range. The significance of this work stems from the fact that the chromatographic approach used is generic and can be applied readily to other analytes, but also because there is an increasing demand for well-characterised imprinted materials that function effectively in aqueous media and are thus well-suited for analytical science applications involving, for example, biofluids and environmental water samples.

  16. The PEAK experience in South Carolina

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-11-01

    The PEAK Institute was developed to provide a linkage for formal (schoolteachers) and nonformal educators (extension agents) with agricultural scientists of Clemson University`s South Carolina Agricultural Experiment Station System. The goal of the Institute was to enable teams of educators and researchers to develop and provide PEAK science and math learning experiences related to relevant agricultural and environmental issues of local communities for both classroom and 4-H Club experiences. The Peak Institute was conducted through a twenty day residential Institute held in June for middle school and high school teachers who were teamed with an Extension agent from their community. These educators participated in hands-on, minds-on sessions conducted by agricultural researchers and Clemson University Cooperative Extension specialists. Participants were given the opportunity to see frontier science being conducted by scientists from a variety of agricultural laboratories.

  17. HPLC柱效对检测水中磺胺二甲基嘧啶色谱条件的影响%HPLC Column Efifciency Inlfuences on Chromatographic Conditions for Detection of Sulfamethazine in Water

    Institute of Scientific and Technical Information of China (English)

    杨娜; 万俊锋; 王岩; 李红丽

    2015-01-01

    When column efficiency decreased, the influence of chromatographic condition for determination of sulfamethazine in water was studied. Compared the old and new chromatographic of column separation effect, symmetry and the peak area of chromatographic peak, the results showed that the old chromatographic column efficiency was reduced, the separation effect of the target was poorer, the target of the absorption peak area was smaller, peak shape was asymmetric. The symmetry of peak shape and seperation effect were improved as 0.125% ice acetic acid add into the mobile phase water to adjust pH value of 4.5.%研究色谱柱的柱效降低后对高效液相色谱测定水中磺胺二甲基嘧啶色谱条件的影响.比较了新旧色谱柱的分离效果、色谱峰的对称性和峰面积,结果表明,旧色谱柱的柱效降低,对目标物的分离效果变差,目标物的吸收峰面积变小,峰形不对称.对色谱条件进行了优化试验,结果表明,对流动相水相添加0.125%的冰乙酸调节pH值为4.5后色谱峰的峰形对称性和分离效果得到改善.

  18. Providing peak river flow statistics and forecasting in the Niger River basin

    Science.gov (United States)

    Andersson, Jafet C. M.; Ali, Abdou; Arheimer, Berit; Gustafsson, David; Minoungou, Bernard

    2017-08-01

    Flooding is a growing concern in West Africa. Improved quantification of discharge extremes and associated uncertainties is needed to improve infrastructure design, and operational forecasting is needed to provide timely warnings. In this study, we use discharge observations, a hydrological model (Niger-HYPE) and extreme value analysis to estimate peak river flow statistics (e.g. the discharge magnitude with a 100-year return period) across the Niger River basin. To test the model's capacity of predicting peak flows, we compared 30-year maximum discharge and peak flow statistics derived from the model vs. derived from nine observation stations. The results indicate that the model simulates peak discharge reasonably well (on average + 20%). However, the peak flow statistics have a large uncertainty range, which ought to be considered in infrastructure design. We then applied the methodology to derive basin-wide maps of peak flow statistics and their associated uncertainty. The results indicate that the method is applicable across the hydrologically active part of the river basin, and that the uncertainty varies substantially depending on location. Subsequently, we used the most recent bias-corrected climate projections to analyze potential changes in peak flow statistics in a changed climate. The results are generally ambiguous, with consistent changes only in very few areas. To test the forecasting capacity, we ran Niger-HYPE with a combination of meteorological data sets for the 2008 high-flow season and compared with observations. The results indicate reasonable forecasting capacity (on average 17% deviation), but additional years should also be evaluated. We finish by presenting a strategy and pilot project which will develop an operational flood monitoring and forecasting system based in-situ data, earth observations, modelling, and extreme statistics. In this way we aim to build capacity to ultimately improve resilience toward floods, protecting lives and

  19. Effect of chromatographic conditions on retention behavior and system efficiency for HPTLC of selected psychotropic drugs on chemically bonded stationary phases.

    Science.gov (United States)

    Petruczynik, Anna; Wróblewski, Karol; Waksmundzka-Hajnos, Monika

    2015-01-01

    Selected psychotropic drug standards have been chromatographed on RP18, CN and diol layers with a variety of aqueous and nonaqueous mobile phases. The effect of buffers at acidic or basic pH, acetic acid, ammonia and diethylamine (DEA) in aqueous mobile phases on retention, efficiency and peak symmetry was examined. Improved peak symmetry and separation selectivity for investigated compounds were observed when ammonia or DEA were used as mobile phase additives. The effect of diethylamine concentration in aqueous eluents on retention, peak symmetry and theoretical plate number obtained on CN plates was also investigated. Because of the strong retention of these basic drugs on stationary phases bonded on silica matrix, nonaqueous eluents containing medium polar diluents, strongly polar modifiers and silanol blockers (ammonia or diethylamine) were applied. Aqueous and nonaqueous eluent systems with the best selectivity and efficiency were used for separate psychotropic drug standards' mixture on CN layer by 2D TLC.

  20. Simple and rapid gas-liquid-solid chromatographic analysis of trace concentrations of acetaldehyde in urban air.

    Science.gov (United States)

    Hoshika, Y

    1977-07-21

    A simple and rapid gas-liquid-solid chromatographic method for the analysis of trace concentrations of acetaldehyde in urban air (in the Nagoya area) was developed, with the use of cold trapping with liquid oxygen. In the analytical main column the conditions were: stationary phase, Triton X-100 (0.4%); support, Carbopack B (60-80 mesh); glass column, 1.5 m X 3 mm I.D.; column temperature, 75 degrees; carrier gas (nitrogen) flow-rate, 50-80 ml/min. In the cold trapping pre-column the conditions were: stationary phase, Tris (2-cyanoethoxy) propane (25%); support, Shimalite (AW, DMCS) (60-80 mesh); glass column, 31 cm X 4 mm I.D.; operating temperature for the trapping, -183 degrees (liquid oxygen temperature); operating temperature for injection of the condensed sample into the gas chromatograph, increased from -183 degrees to +100 degrees for 2 min. The acetaldehyde peak was identified by the disappearance method with a 2,4-dinitrophenylhydrazine-orthophosphoric acid-glass beads column. The ranges and average concentrations of acetaldehyde detected in 13 urban air samples were 1.5-9.6 and 4.7 ppb, respectively.

  1. High performance liquid chromatographic separation of eight drugs collected in Chinese Pharmacopoeia 2010 on amylose ramification chiral stationary phase

    Directory of Open Access Journals (Sweden)

    Yan Wang

    2012-10-01

    Full Text Available The enantiomers separation of eight pharmaceutical racemates collected in Chinese Pharmacopoeia 2010 (Ch.P2010, including nitrendipine, felodipine, omeprazole, praziquantel, sulpiride, clenbuterol hydrochloride, verapamil hydrochloride and chlorphenamine maleate, was performed on chiral stationary phase of amylose ramification by high performance liquid chromatography (HPLC on Chiralpak AD-H column and Chiralpak AS-H column with the mobile phase consisted of isopropanol and n-hexane. The detection wavelength and the flow rate were set at 254 nm and 0.7 mL/min, respectively. The effects of proportion of organic additives, alcohol displacer and temperature on the separation were investigated. The results indicated that eight chiral drugs were separated on chiral stationary phase of amylase ramification in normal phase chromatographic system. The chromatographic retention and resolution of enantiomers were adjusted by factors, including the changes of the concentration of alcohol displacer in mobile phase, organic alkaline modifier and column temperature. It was shown that the resolution was improved with reducing concentration of alcohol displacer. When the concentration of organic alkaline modifier was 0.2%, the resolution and the peak shape were fairly good. Most racemates mentioned above had the best resolution at column temperature of 25 °C. The best temperature should be kept unchanged in the process of separation so as to obtain stable separation results.

  2. Size-exclusion chromatographic NMR under HR-MAS.

    Science.gov (United States)

    Lucena Alcalde, Guillermo; Anderson, Natalie; Day, Iain J

    2017-05-01

    The addition of stationary phases or sample modifiers can be used to modify the separation achievable in the diffusion domain of diffusion NMR experiments or provide information on the nature of the analyte-sample modifier interaction. Unfortunately, the addition of insoluble chromatographic stationary phases can lead to line broadening and degradation in spectral resolution, largely because of differences in magnetic susceptibility between the sample and the stationary phase. High-resolution magic angle spinning (HR-MAS) techniques can be used to remove this broadening. Here, we attempt the application of HR-MAS to size-exclusion chromatographic NMR with limited success. Observed diffusion coefficients for polymer molecular weight reference standards are shown to be larger than those obtained on static samples. Further investigation reveals that under HR-MAS it is possible to obtain reasonably accurate estimates of diffusion coefficients, using either full rotor synchronisation or sophisticated pulse sequences. The requirement for restricting the sample to the centre of the MAS rotor to ensure homogeneous magnetic and RF fields is also tested. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Ion Chromatographic Analyses of Sea Waters, Brines and Related Samples

    Directory of Open Access Journals (Sweden)

    Nataša Gros

    2013-06-01

    Full Text Available This review focuses on the ion chromatographic methods for the analyses of natural waters with high ionic strength. At the beginning a natural diversity in ionic composition of waters is highlighted and terminology clarified. In continuation a brief overview of other review articles of potential interest is given. A review of ion chromatographic methods is organized in four sections. The first section comprises articles focused on the determination of ionic composition of water samples as completely as possible. The sections—Selected Anions, Selected Cations and Metals—follow. The most essential experimental conditions used in different methods are summarized in tables for a rapid comparison. Techniques encountered in the reviewed articles comprise: direct determinations of ions in untreated samples with ion- or ion-exclusion chromatography, or electrostatic ion chromatography; matrix elimination with column-switching; pre-concentration with a chelation ion chromatography and purge-and-trap pre-concentration. Different detection methods were used: non-suppressed conductometric or suppressed conductometric, direct spectrometric or spectrometric after a post-column derivetization, and inductively coupled plasma in combination with optical emission or mass spectrometry.

  4. [Chromatographic separation of plasmid DNA by anion-exchange cryogel].

    Science.gov (United States)

    Guo, Yantao; Shen, Shaochuan; Yun, Junxian; Yao, Kejian

    2012-08-01

    Plasmid DNA (pDNA) is used as an important vector for gene therapy, and its wide application is restricted by the purity and yield. To obtain high-purity pDNA, a chromatographic method based on anion-exchange supermacroporous cryogel was explored. The anion-exchange cryogel was prepared by grafting diethylaminoethyl-dextran to the epoxide groups of polyacrylamide-based matrix and pUC19 plasmid was used as a target to test the method. The plasmid was transferred into Escherichia coli DH5alpha, cultivated, harvested and lysed. The obtained culture was centrifuged and the supernatant was used as the plasmid feedstock, which was loaded into the anion-exchange cryogel bed for chromatographic separation. By optimizing the pH of running buffer and the elution conditions, high-purity pDNA was obtained by elution with 0.5 mol/L sodium chloride solution at pH 6.6. Compared to the traditional methods for purification of pDNA, animal source enzymes and toxic reagents were not involved in the present separation process, ensuring the safety of both the purification operations and the obtained pDNA.

  5. Convective and Diffusive O2 Transport Components of Peak Oxygen Uptake Following Long-duration Spaceflight

    Science.gov (United States)

    Ade, Carl J.; Moore, A. D.

    2014-01-01

    Spaceflight reduces aerobic capacity and may be linked with maladaptations in the O2 transport pathway. The aim was to 1) evaluate the cardiorespiratory adaptations following 6 months aboard the International Space Station and 2) model the contributions of convective (Q (raised dot) O2) and peripheral diffusive (DO2) components of O2 transport to changes in peak O2 uptake (V (raised dot) O2PEAK). To date, 1 male astronaut (XX yrs) completed an incremental exercise test to measure V (raised dot) O2PEAK prior to and 2 days post-flight. Cardiac output (Q (raised dot) ) was measured at three submaximal work rates via carbon dioxide rebreathing. The Q (raised dot) :V (raised dot) O2 relationship was extrapolated to V (raised dot) O2PEAK to determine Q (raised dot) PEAK. Hemoglobin concentration was measured at rest via a venous blood sample. These measurements were used to model the changes in Q (raised dot) O2 and DO2 using Fick's principle of mass conservation and Law of Diffusion as established by Wagner and colleagues (Annu. Rev. Physiol 58: 21-50, 1996 and J. Appl. Physiol. 73: 1067-1076, 1992). V (raised dot) O2PEAK decreased postflight from 3.72 to 3.45 l min-1, but Q (raised dot) PEAK increased from 24.5 to 27.7 l min-1. The decrease in V (raised dot) O2PEAK post-flight was associated with a 21.2% decrease in DO2, an 18.6% decrease in O2 extraction, but a 3.4% increase in Q (raised dot) O2. These preliminary data suggest that long-duration spaceflight reduces peripheral diffusing capacity and that it largely contributes to the post-flight decrease in aerobic capacity.

  6. Multivariate Chemometrics with Regression and Classification Analyses in Heroin Profiling Based on the Chromatographic Data.

    Science.gov (United States)

    B Gadžurić, Slobodan; O Podunavac Kuzmanović, Sanja; B Vraneš, Milan; Petrin, Marija; Bugarski, Tatjana; Kovačević, Strahinja Z

    2016-01-01

    The purpose of this work is to promote and facilitate forensic profiling and chemical analysis of illicit drug samples in order to determine their origin, methods of production and transfer through the country. The article is based on the gas chromatography analysis of heroin samples seized from three different locations in Serbia. Chemometric approach with appropriate statistical tools (multiple-linear regression (MLR), hierarchical cluster analysis (HCA) and Wald-Wolfowitz run (WWR) test) were applied on chromatographic data of heroin samples in order to correlate and examine the geographic origin of seized heroin samples. The best MLR models were further validated by leave-one-out technique as well as by the calculation of basic statistical parameters for the established models. To confirm the predictive power of the models, external set of heroin samples was used. High agreement between experimental and predicted values of acetyl thebaol and diacetyl morphine peak ratio, obtained in the validation procedure, indicated the good quality of derived MLR models. WWR test showed which examined heroin samples come from the same population, and HCA was applied in order to overview the similarities among the studied heroine samples.

  7. An improved extraction chromatographic resin for the separation of uranium from acidic nitrate media

    Energy Technology Data Exchange (ETDEWEB)

    Dietz, M.L.; Horwitz, E.P.; Sajdak, L.R.; Chiarizia, R. [Chemistry Division, Argonne National Laboratory, 60439 Argonne, IL (United States)

    2001-07-06

    The preparation and characterization of a new extraction chromatographic resin exhibiting extraordinarily strong retention of hexavalent uranyl ion over a wide range of nitric acid concentrations and very high selectivity for U(VI) over Fe(III) and numerous other cations is described. This new material (designated U/TEVA-2) comprises a novel liquid stationary phase consisting of an equimolar mixture of diamyl amylphosphonate (DA[AP]) and Cyanex 923{sup registered} (a commercially available trialkyl-phosphine oxide, TRPO) sorbed on silanized silica or Amberchrom CG-71. Cyanex 923 is shown to be preferable to a related TRPO, Cyanex 925{sup registered}, due to its lower viscosity and higher selectivity for U(VI) over Fe(III). The retention of uranyl nitrate by the U/TEVA-2 resin, as measured by the k' values (number of free column values to peak maximum) is >5000 from approximately 0.1 to 8 M HNO{sub 3}. The ability of the new resin to strongly and selectively retain U(VI) from such a wide range of acid concentrations, along with its favorable physical properties, make it a good candidate for application in the separation and preconcentration of U(VI) from complex environmental, biological, and nuclear waste samples for subsequent determination.

  8. An improved extraction chromatographic resin for the separation of uranium from acidic nitrate media.

    Science.gov (United States)

    Dietz, M L; Horwitz, E P; Sajdak, L R; Chiarizia, R

    2001-07-01

    The preparation and characterization of a new extraction chromatographic resin exhibiting extraordinarily strong retention of hexavalent uranyl ion over a wide range of nitric acid concentrations and very high selectivity for U(VI) over Fe(III) and numerous other cations is described. This new material (designated U/TEVA-2) comprises a novel liquid stationary phase consisting of an equimolar mixture of diamyl amylphosphonate (DA[AP]) and Cyanex 923((R)) (a commercially available trialkyl-phosphine oxide, TRPO) sorbed on silanized silica or Amberchrom CG-71. Cyanex 923 is shown to be preferable to a related TRPO, Cyanex 925((R)), due to its lower viscosity and higher selectivity for U(VI) over Fe(III). The retention of uranyl nitrate by the U/TEVA-2 resin, as measured by the k' values (number of free column values to peak maximum) is >5000 from approximately 0.1 to 8 M HNO(3). The ability of the new resin to strongly and selectively retain U(VI) from such a wide range of acid concentrations, along with its favorable physical properties, make it a good candidate for application in the separation and preconcentration of U(VI) from complex environmental, biological, and nuclear waste samples for subsequent determination.

  9. An improved ion chromatographic method for determination of trace levels of perchlorate in environmental water

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    An improved ion chromatographic (IC)method was developed to determine trace levels of perchlorate in environmental water samples.Perchlorate was separated in the hydroxide selective column IonPac AS 16 using NaOH as an eluent with an organic modifier.To eliminate the coelution of perchlorate and 4-chlorobenzene sulfonate (4-CBS),an organic solvent as modifier was added to the eluent.Of four organic solvents studied,acetonitrile proved to be the most efficient based on the retention time of perchlorate and 4-CBS.To improve the method sensitivity,a concentrator column (AGI9) was used to concentrate perchlorate online.With the adoption of a preconcentration step,the sensitivity of our method was improved and the method detection limit (MDL) was reduced to 0.1 μg/L.The linear range was from 0.2 μg/L to 200/.μg/L with a linear correlation coefficient of 0.9989 and the relative standard deviation (RSD) of peak area for eleven successive injections of 0.5 μg/L perehlorate was 4.2%.The method had been applied to the determination of perchlorate in some real environmental water samples and recovery was between 93% and 113%.

  10. Chromatographic evaluation and antimicrobial activity of Neem (Azadirachta indica A. Juss., Meliaceae leaves hydroalcoholic extracts

    Directory of Open Access Journals (Sweden)

    Priscila D. Alves

    2009-06-01

    Full Text Available Neem (Azadirachta indica is an Indian tree well known for its several pharmacological activities, including antimicrobial activity. More than 300 composites have already been isolated and azadirachtin (AZA is its main active component. In the present work, Neem leaves hydroalcoholic extracts were prepared by percolation in 96% ethanol different concentrations (50%, 60%, 70%, 80% and 90% (v/v. The presence of AZA was tested by TLC by eluting the extracts and a standard solution of AZA through a chromatographic plate developed with anisaldehyde/sulfuric acid solution followed by heating. By HPLC, extracts elution took place on a C18 column, water:acetonitrile (60:40 as mobile phase, 1.0 mL/min flow rate and detection at λ217 nm. The extracts did not display AZA spots or peaks, however, they were tested against Gram-positive and Gram-negative bacteria, yeasts and a mold fungus. The extracts were tested in different increasing concentrations, in order to detect a dose-dependent relationship of the activity. Despite the absence of AZA, the 70% and 80% (v/v ethanol extracts showed activity against Staphylococcus aureus. However, this activity was not dose-dependent according to Tukey's test (q0,05;3;7.

  11. Some Phenomenological Aspects of the Peak Experience

    Science.gov (United States)

    Rosenblatt, Howard S.; Bartlett, Iris

    1976-01-01

    This article relates the psychological dynamics of "peak experiences" to two concepts, intentionality and paradoxical intention, within the philosophical orientation of phenomenology. A review of early philosophical theories of self (Kant and Hume) is presented and compared with the experiential emphasis found in the phenomenology of Husserl.…

  12. Some Phenomenological Aspects of the Peak Experience

    Science.gov (United States)

    Rosenblatt, Howard S.; Bartlett, Iris

    1976-01-01

    This article relates the psychological dynamics of "peak experiences" to two concepts, intentionality and paradoxical intention, within the philosophical orientation of phenomenology. A review of early philosophical theories of self (Kant and Hume) is presented and compared with the experiential emphasis found in the phenomenology of Husserl.…

  13. Real estate price peaks: a comparative overview

    CERN Document Server

    Röhner, B M

    2006-01-01

    First, we emphasize that the real estate price peaks which are currently under way in many industrialized countries (one important exception is Japan) share many of the characteristics of previous historical price peaks. In particular, we show that: (i) In the present episode real price increases are, at least for now, of the same order of magnitude as in previous episodes, typically of the order of 80 percent to 100 percent. (ii) Historically, price peaks turned out to be symmetrical with respect to the peak; soft landing, i.e. an upgoing phase followed by a plateau, has rarely (if ever) been observed. (iii) The inflated demand is mainly boosted by investors and high-income buyers. (iv) In the present as well as in previous episodes, the main engines in the upgoing phase have been the hot markets which developed in major cities such as London, Los Angeles, New York, Paris, San Francisco or Sydney. In our conclusion, we propose a prediction for real estate prices in the West of the United States over the peri...

  14. Spanish Peaks, Sangre de Cristo Range, Colorado

    Science.gov (United States)

    2002-01-01

    The Spanish Peaks, on the eastern flank of the Sangre de Cristo range, abruptly rise 7,000 feet above the western Great Plains. Settlers, treasure hunters, trappers, gold and silver miners have long sighted on these prominent landmarks along the Taos branch of the Santa Fe trail. Well before the westward migration, the mountains figured in the legends and history of the Ute, Apache, Comanche, and earlier tribes. 'Las Cumbres Espanolas' are also mentioned in chronicles of exploration by Spaniards including Ulibarri in 1706 and later by de Anza, who eventually founded San Francisco (California). This exceptional view (STS108-720-32), captured by the crew of Space Shuttle mission STS108, portrays the Spanish Peaks in the context of the southern Rocky Mountains. Uplift of the Sangre de Cristo began about 75 million years ago and produced the long north-trending ridges of faulted and folded rock to the west of the paired peaks. After uplift had ceased (26 to 22 million years ago), the large masses of igneous rock (granite, granodiorite, syenodiorite) that form the Peaks were emplaced (Penn, 1995-2001). East and West Spanish Peaks are 'stocks'-bodies of molten rock that intruded sedimentary layers, cooled and solidified, and were later exposed by erosion. East Peak (E), at 12,708 ft is almost circular and is about 5 1/2 miles long by 3 miles wide, while West Peak (W), at 13,623 ft is roughly 2 3/4 miles long by 1 3/4 miles wide. Great dikes-long stone walls-radiate outward from the mountains like spokes of a wheel, a prominent one forms a broad arc northeast of East Spanish Peak. As the molten rock rose, it forced its way into vertical cracks and joints in the sedimentary strata; the less resistant material was then eroded away, leaving walls of hard rock from 1 foot to 100 feet wide, up to 100 feet high, and as long as 14 miles. Dikes trending almost east-west are also common in the region. For more information visit: Sangres.com: The Spanish Peaks (accessed January 16

  15. Suspended particle and pathogen peak discharge buffering by a surface-flow constructed wetland

    NARCIS (Netherlands)

    Mulling, B.T.M.; van den Boomen, R.M.; van der Geest, H.G.; Kappelhof, J.W.N.M.; Admiraal, W.

    2013-01-01

    Constructed wetlands (CWs) have been shown to improve the water quality of treated wastewater. The capacity of CWs to reduce nutrients, pathogens and organic matter and restore oxygen regime under normal operating conditions cannot be extrapolated to periods of incidental peak discharges. The

  16. Battery Peak Power Shaving Strategy to Prolong Battery Life for Electric Buses

    NARCIS (Netherlands)

    Pham, T.H.; Rosea, B.; Wilkins, S.

    2016-01-01

    This paper presents a battery peak power shaving strategy for battery electric buses. The developed strategy restricts the battery charge/discharge power when the propulsion power demand is high to avoid high deterioration of the battery capacity during operation. Without reducing the propulsion

  17. Capacity at Railway Stations

    DEFF Research Database (Denmark)

    Landex, Alex

    2011-01-01

    Stations do have other challenges regarding capacity than open lines as it is here the traffic is dispatched. The UIC 406 capacity method that can be used to analyse the capacity consumption can be exposed in different ways at stations which may lead to different results. Therefore, stations need...... special focus when conducting UIC 406 capacity analyses.This paper describes how the UIC 406 capacity method can be expounded for stations. Commonly for the analyses of the stations it is recommended to include the entire station including the switch zone(s) and all station tracks. By including the switch...... is changed, this paper recommends that the railway lines are not always be divided. In case trains turn around on open (single track) line, the capacity consumption may be too low if a railway line is divided. The same can be the case if only few trains are overtaken at an overtaking station. For dead end...

  18. Evaluation of railway capacity

    DEFF Research Database (Denmark)

    Landex, Alex; Kaas, Anders H.; Schittenhelm, Bernd

    2006-01-01

    This paper describes the relatively new UIC 406 method for calculating capacity consumption on railway lines. The UIC 406 method is an easy and effective way of calculating the capacity consumption, but it is possible to expound the UIC 406 method in different ways which can lead to different...... capacity consumptions. This paper describes the UIC 406 method and how it is expounded in Denmark. The paper describes the importance of choosing the right length of the line sections examined and how line sections with multiple track sections are examined. Furthermore, the possibility of using idle...... capacity to run more trains is examined. The paper presents a method to examine the expected capacity utilization of future timetables. The method is based on the plan of operation instead of the exact (known) timetable. At the end of the paper it is described how it is possible to make capacity statements...

  19. Validation of stability indicating high performance liquid chromatographic method for estimation of Desloratadine in tablet formulation

    Directory of Open Access Journals (Sweden)

    R.B. Patel

    2017-02-01

    Full Text Available A simple, sensitive and specific stability indicating high performance liquid chromatographic (HPLC method for the estimation of Desloratadine was developed and validated. Desloratadine was separated and quantitated on Inertsil ODS-3 V column (250 mm length, 4.6 mm id, 5 μm particle size using a mixture of methanol–phosphate buffer of pH 7.0 (70:30 v/v as a mobile phase and at a flow rate of 1.0 mL/min. Quantification was achieved with an UV detector at 254 nm over the concentration range of 5–75 μg/mL. The applied HPLC method allowed the separation and quantification of Desloratadine with good linearity (r2 = 0.999 in the studied concentration range. Limit of detection and limit of quantification were found to be 1.28 μg/mL and 3.89 μg/mL, respectively. The method was validated as per the International Conference on Harmonization (ICH guidelines. Desloratadine stock solution was subjected to different stress conditions. The degraded product peaks were well resolved from the pure drug peak with significant difference in their retention time values. Stressed samples were assayed using developed HPLC method. Statistical analysis of the data showed that the method is precise, accurate, reproducible, and selective for the analysis of Desloratadine. The method was successfully applied to the estimation of Desloratadine in tablet dosage form.

  20. Capacity Building in Vietnam

    OpenAIRE

    Adam McCarty

    2001-01-01

    This report is the outcome of a study commissioned to examine the capacity building needs in Vietnam, and is a supplementary document to the Asian Development Bank's Country Operational Strategy for Vietnam. Vietnam's needs in terms of capacity building are particularly important given that is it a transitional economy and also one with little institutional experience in dealing with the international donor community. This paper examines the international awareness of capacity building and ca...

  1. Liquid chromatographic resolution of racemic 2-oxazolidinones and their analogs on seven pirkle-type chiral stationary phases

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Jeong Jae [Dept. of Chemistry, Graduate School, Kyungpook National University, Daegu (Korea, Republic of); Hyun, Myung Ho [Dept. of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Pusan (Korea, Republic of); Amstrong, Daniel W.; Breitbach, Zachary S. [Dept. of Chemistry, University of Texas at Arlington, Arlington (United States)

    2015-02-15

    Oxazolidinones are mainly used as antimicrobials and have an antibacterial effect due to their action as protein synthesis inhibitors, wherein they target an early step involving the binding of N-formylmethionyl-tRNA to the ribosome. Various oxazolidinones have been used as antibiotics with usually the (S)-form being active. 2–5 The chiral separation of nonoxazolidinone samples has been previously reported. Separation of DUP-105, ZTR-5, and 3-amino2-oxazolidinone derivatives was performed on polysaccharide columns. All the racemic and optically active samples were dissolved in methylene chloride or methanol (usually 2.5 mg/mL) and then used for resolution on CSPs. In most cases, an injection volume of 5 μL was used; however, it was varied slightly according to the size of the chromatographic peaks that corresponded to the two enantiomers.

  2. RIGID GIGAPOROUS CHROMATOGRAPHIC MEDIA AND THEIR POTENTIAL IMPACT ON DOWNSTREAM PROCESSING

    Institute of Scientific and Technical Information of China (English)

    Tingyue Gu; Weiqing Zhou; Guanghui Ma; Zhiguo Su

    2005-01-01

    More and more biomolecules are being produced by the biotechnology industry for applications ranging from medicine and food to engineering materials. Liquid chromatography plays a center-stage role in a typical downstream process producing biomolecules such as recombinant proteins. Rigid gigaporous media are porous particles possessing large transecting through-pores with a pore-to-particle diameter ratio of dpore/dparticle> 0.01. They allow convective flow in the large through-pores, while the smaller diffusion-pores (typically several hundred angstroms in size) supply the needed surface areas. Because of the transecting gigapores, a portion of the mobile phase flows through the pores in addition to fluid flow in the interstitial spaces between the particles in a packed-bed column. This considerably lowers the operating column pressure drop. This lower pressure drop makes axial-direction scale-up of chromatographic columns possible to avoid pancake columns that invariably degrade separation resolution. The large gigapores also make the binding sites on the diffusion pore surfaces more accessible, thus increasing the loading capacity of large protein molecules that can be hindered sterically if only diffusion pores are present. This work discusses the development of rigid gigaporous media and their potential impact on the design of multi-stage downstream process from the angle of multi-scale analysis.

  3. Preparation of Medium Cation Exchange Stationary Phase of Polymeric Matrix and Their Chromatographic Properties

    Institute of Scientific and Technical Information of China (English)

    CHEN,Gang; GONG,Bo-Lin; BAI,Quan; GENG,Xin-Du

    2007-01-01

    Based on the monodisperse poly(glycidyl methacrylate-co-ethylenedimethacrylate) beads (PGMA/EDMA) with macropore as a medium, a new hydrophilic medium cation exchange (MCX) stationary phase for HPLC was synthesized by a new chemically modified method. The stationary phase was evaluated with the property of ion exchange, separability, reproducibility, hydrophilicity, effect of salt concentration, salt types, column loading and pH on the separation and retention of proteins in detail. It was found that it follows ion exchange chromatographic (IEC)retention mechanism. The measured bioactivity recovery for lysozyme was (96±5)%. The dynamic protein loading capacity of the synthesized MCX packings was 21.8 mg/g. Five proteins were almost completely separated within 6.0 min at a flow rate of 4 mL/min using the synthesized MCX resin. The MCX resin was also used for the rapid separation and purification of lysozyme from egg white with only one step. The purity and specific bioactivity of the purified lysozyme was found more than 95% and 70345 U/mg, respectively.

  4. Ventilation Limits Aerobic Capacity after Functional Electrical Stimulation Row Training in High Spinal Cord Injury.

    Science.gov (United States)

    Qiu, Shuang; Alzhab, Saeed; Picard, Glen; Taylor, J Andrew

    2016-06-01

    In the able-bodied, exercise training results in increased ventilatory capacity to meet increased aerobic demands of trained skeletal muscle. However, after spinal cord injury (SCI), peak ventilation can be limited by pulmonary muscle denervation. In fact, peak ventilation may restrict aerobic capacity in direct relation to injury level. Hybrid functional electrical stimulation (FES) exercise training results in increased aerobic capacity and dissociation between aerobic capacity and injury level in those with injuries at T3 and below. However, injuries above T3 have the greatest pulmonary denervation, and ventilatory capacity may restrict the increase in aerobic capacity with hybrid FES training. We assessed relationships among injury level, peak ventilation, and peak aerobic capacity and calculated oxygen uptake efficiency slope during hybrid FES exercise in 12 individuals (1 female) with SCI at level T2 to C4 (injury duration = 0.33-33 yr, age = 20-60 yr), before and after 6 months of FES-row training (FES-RT). Training increased peak aerobic capacity by 12% (P = 0.02) with only a modest increase in peak ventilation (7 of 12 subjects, P = 0.09). Both before and after training, injury level was directly related to peak ventilation (R = 0.48 and 0.43) and peak aerobic capacity (R = 0.70 and 0.55). Before training, the relationship of peak aerobic capacity to peak ventilation was strong (R = 0.62), however, after training, this relationship became almost completely linearized (R = 0.84). In addition, oxygen uptake efficiency slope increased by 11% (P injuries (above T3) appears to restrict aerobic capacity.

  5. Quercetin-imprinted chromatographic sorbents revisited: optimization of synthesis and rebinding protocols for application to natural resources.

    Science.gov (United States)

    Pardo, Antonelle; Mespouille, Laetitia; Blankert, Bertrand; Trouillas, Patrick; Surin, Mathieu; Dubois, Philippe; Duez, Pierre

    2014-10-17

    Molecularly imprinted polymers (MIPs) based on quercetin and synthesized by either bulk, precipitation or suspension polymerization were characterized in terms of size and shape by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). After a study of rebinding protocols, the optimal materials were evaluated as sorbents for solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) to confirm the presence of imprinted cavities and to assess their selectivity. Besides quercetin, other structurally related natural compounds, naringenin, daidzein and curcumin, were employed for selectivity tests of MIPs. Although rebinding protocols previously described for such MIPs are typically based on binding, washing and eluting methanol-based solutions, we show that this highly polar solvent leads to weak specific interactions (imprinting factor2.4). This calls for reviewing most of previously published data on quercetin-MIPs; in proper binding conditions, published MIPs may prove more performing than initially assessed. As expected, tested MIPs exhibited the highest selective rebinding towards quercetin template (imprinting effect, quercetin, 3.41; naringenin, 1.54; daidzein, 1.38; curcumin, 1.67); the differences in selectivity between quercetin analogues were explained by the ligand geometries and H-bonding patterns obtained from quantum-chemical calculations. The evaluation of MIPs under identical analytical conditions allowed investigating the effect of the production method on chromatographic performances. The MIPs in bead materials (for quercetin, peak width, 0.69; number of theoretical plates, 143; symmetry factor, 2.22) provided a significant improvement in chromatographic efficiency over the bulk materials (for quercetin, peak width, 1.25; number of theoretical plates, 115; symmetry factor, 2.92). Using the quercetin-beaded MIP as SPE sorbent, quercetin was selectively extracted from Allium cepa L. extract. The MIP

  6. Contributions of Astronauts Aerobic Exercise Intensity and Time on Change in VO2peak during Spaceflight

    Science.gov (United States)

    Downs, Meghan E.; Buxton, Roxanne; Moore, Alan; Ploutz-Snyder, Robert; Ploutz-Snyder, Lori

    2014-01-01

    There is considerable variability among astronauts with respect to changes in maximal aerobic capacity (VO2peak) during International Space Station (ISS) missions, ranging from a 5% increase to 30% decline. Individual differences may be due to in-flight aerobic exercise time and intensity. PURPOSE: To evaluate the effects of in-flight aerobic exercise time and intensity on change in VO2peak during ISS missions. METHODS: Astronauts (N=11) performed peak cycle tests approx 60 days before flight (L-60), on flight day (FD) approx 14, and every approx 30 days thereafter. Metabolic gas analysis and heart rate (HR) were measured continuously during the test using the portable pulmonary function system. HR and duration of each in-flight cycle ergometer and treadmill (TM) session were recorded and averaged in time segments corresponding to each peak test. Mixed effects linear regression with exercise mode (TM or cycle) as a categorical variable was used to assess the contributions of exercise intensity (%time >70% peak HR or %time >90% peak HR) and time (min/wk), adjusted for body weight, on %change in VO2peak during the mission, and incorporating the repeated-measures experimental design. RESULTS: 110 observations were included in the model (4-6 peak cycle tests per astronaut, 2 exercise devices). VO2peak was reduced from preflight throughout the mission (FD14: 13+/-13% and FD 105: 8+/-10%). Exercise intensity (%peak HR: FD14=66+/-14; FD105=75+/-8) and time (min/wk: FD14=82+/-46; FD105=158+/-40) increased during flight. The models showed main effects for exercise time and intensity with no interactions between time, intensity, and device (70% peak HR: time [z-score=2.39; P=0.017], intensity [z-score=3.51; P=0.000]; 90% peak HR: time [zscore= 3.31; P=0.001], intensity [z-score=2.24; P=0.025]). CONCLUSION: Exercise time and intensity independently contribute to %change in VO2peak during ISS missions, indicating that there are minimal values for exercise time and intensity

  7. Similarity analyses of chromatographic herbal fingerprints: A review

    Energy Technology Data Exchange (ETDEWEB)

    Goodarzi, Mohammad [Department of Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research, Vrije Universiteit Brussel, Laarbeeklaan 103, B-1090 Brussels (Belgium); Russell, Paul J. [Safety and Environmental Assurance Centre, Unilever, Colworth Science Park, Sharnbrook, Bedfordshire MK44 1LQ (United Kingdom); Vander Heyden, Yvan, E-mail: yvanvdh@vub.ac.be [Department of Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research, Vrije Universiteit Brussel, Laarbeeklaan 103, B-1090 Brussels (Belgium)

    2013-12-04

    Graphical abstract: -- Highlights: •Similarity analyses of herbal fingerprints are reviewed. •Different (dis)similarity approaches are discussed. •(Dis)similarity-metrics and exploratory-analysis approaches are illustrated. •Correlation and distance-based measures are overviewed. •Similarity analyses illustrated by several case studies. -- Abstract: Herbal medicines are becoming again more popular in the developed countries because being “natural” and people thus often assume that they are inherently safe. Herbs have also been used worldwide for many centuries in the traditional medicines. The concern of their safety and efficacy has grown since increasing western interest. Herbal materials and their extracts are very complex, often including hundreds of compounds. A thorough understanding of their chemical composition is essential for conducting a safety risk assessment. However, herbal material can show considerable variability. The chemical constituents and their amounts in a herb can be different, due to growing conditions, such as climate and soil, the drying process, the harvest season, etc. Among the analytical methods, chromatographic fingerprinting has been recommended as a potential and reliable methodology for the identification and quality control of herbal medicines. Identification is needed to avoid fraud and adulteration. Currently, analyzing chromatographic herbal fingerprint data sets has become one of the most applied tools in quality assessment of herbal materials. Mostly, the entire chromatographic profiles are used to identify or to evaluate the quality of the herbs investigated. Occasionally only a limited number of compounds are considered. One approach to the safety risk assessment is to determine whether the herbal material is substantially equivalent to that which is either readily consumed in the diet, has a history of application or has earlier been commercialized i.e. to what is considered as reference material. In order

  8. Development and Validation of High Performance Liquid Chromatographic Method for the Simultaneous Determination of Ceftazidime and Sulbactam in Spiked Plasma and Combined Dosage form-Zydotam

    Directory of Open Access Journals (Sweden)

    Masoom R. Siddiqui

    2009-01-01

    Full Text Available Problem statement: To develop a sensitive method to determine simultaneously ceftizidime and sulbactam in spiked plasma and combined formulation. Approach: In this study an isocratic High performance liquid chromatographic method with UV detection at 230 nm was described for simultaneous determination of Ceftazidime and sulbactam sodium in plasma and combined dosage form. Chromatographic separation of two drugs was achieved on a Hypersil ODS C-18 column using a mobile phase consisting of a binary mixture of acetonitrile and tetrabutyl ammonium hydroxide adjusted to pH 5.0 with orthophosphoric acid in ratio 25:75. Results: The developed performance liquid chromatographic method offers symmetric peak shape, good resolution and reasonable retention time for both drugs. Linearity, accuracy and precision were found to be acceptable over the concentration range of 125-625 ppm for Ceftazidime and 62.5-312.5 ppm for sulbactam sodium. Conclusion: The results showed that this method could be well used for the simultaneous estimation of Ceftazidime and Sulbactam in plasma and combined formulation.

  9. Effects of muscle electrical stimulation on peak VO2 in cardiac transplant patients.

    Science.gov (United States)

    Vaquero, A F; Chicharro, J L; Gil, L; Ruiz, M P; Sánchez, V; Lucía, A; Urrea, S; Gómez, M A

    1998-07-01

    Peak oxygen consumption (peak VO2) has become a critical component in the evaluation of heart transplant recipients (HTR). In these patients, peak VO2 remains low after cardiac transplantation mainly because of persisting peripheral limitations in the working muscles. Muscular electrical stimulation, on the other hand, has been shown to enhance the oxidative capacity of healthy muscle. It was the purpose of our investigation to study the effects of ES on the peak VO2 of HTR. Fourteen (11 males and 3 females) HTR (age: 57+/-7yr, mean +/- SD; height: 163+/-7 cm, weight: 70.5+/-8.6 kg) were selected as subjects and each of them was randomly assigned to one of two groups: (a) group EXP (n = 7), receiving electrical stimulation on both quadriceps muscles during a period of 8 weeks, and (b) group CONT (n = 7), not receiving electrical stimulation. Before (PRE) and after (POST) the aforementioned 8-week period, respectively, all the subjects performed a cardiopulmonary exercise test (ramp protocol) on a cycle ergometer for peak VO2 determination. PRE values of peak VO2 were similar in both groups (17.1+/-2.0 vs 16.9+/-3.8ml x kg(-1) x min(-1) in EXP and CONT, respectively). However, peak values of VO2 significantly increased in EXP (p < 0.05) after the period of electrical stimulation (POST peak VO2: 18.7+/-2.0ml x kg(-1)), whereas no change was observed in CONT (POST peak VO2: 16.2+/-3.2 ml x kg(-1) x min(-1)). In conclusion, electrical stimulation could therefore be used to improve the functional capacity of HTR, and might be included in the rehabilitation programs of this population group.

  10. Predicting VO2peak from Submaximal- and Peak Exercise Models: The HUNT 3 Fitness Study, Norway.

    Directory of Open Access Journals (Sweden)

    Henrik Loe

    Full Text Available Peak oxygen uptake (VO2peak is seldom assessed in health care settings although being inversely linked to cardiovascular risk and all-cause mortality. The aim of this study was to develop VO2peak prediction models for men and women based on directly measured VO2peak from a large healthy population.VO2peak prediction models based on submaximal- and peak performance treadmill work were derived from multiple regression analysis. 4637 healthy men and women aged 20-90 years were included. Data splitting was used to generate validation and cross-validation samples.The accuracy for the peak performance models were 10.5% (SEE = 4.63 mL⋅kg(-1⋅min(-1 and 11.5% (SEE = 4.11 mL⋅kg(-1⋅min(-1 for men and women, respectively, with 75% and 72% of the variance explained. For the submaximal performance models accuracy were 14.1% (SEE = 6.24 mL⋅kg(-1⋅min(-1 and 14.4% (SEE = 5.17 mL⋅kg(-1⋅min(-1 for men and women, respectively, with 55% and 56% of the variance explained. The validation and cross-validation samples displayed SEE and variance explained in agreement with the total sample. Cross-classification between measured and predicted VO2peak accurately classified 91% of the participants within the correct or nearest quintile of measured VO2peak.Judicious use of the exercise prediction models presented in this study offers valuable information in providing a fairly accurate assessment of VO2peak, which may be beneficial for risk stratification in health care settings.

  11. Effect of gear ratio on peak power and time to peak power in BMX cyclists.

    Science.gov (United States)

    Rylands, Lee P; Roberts, Simon J; Hurst, Howard T

    2017-03-01

    The aim of this study was to ascertain if gear ratio selection would have an effect on peak power and time to peak power production in elite Bicycle Motocross (BMX) cyclists. Eight male elite BMX riders volunteered for the study. Each rider performed three, 10-s maximal sprints on an Olympic standard indoor BMX track. The riders' bicycles were fitted with a portable SRM power meter. Each rider performed the three sprints using gear ratios of 41/16, 43/16 and 45/16 tooth. The results from the 41/16 and 45/16 gear ratios were compared to the current standard 43/16 gear ratio. Statistically, significant differences were found between the gear ratios for peak power (F(2,14) = 6.448; p = .010) and peak torque (F(2,14) = 4.777; p = .026), but no significant difference was found for time to peak power (F(2,14) = 0.200; p = .821). When comparing gear ratios, the results showed a 45/16 gear ratio elicited the highest peak power,1658 ± 221 W, compared to 1436 ± 129 W and 1380 ± 56 W, for the 43/16 and 41/16 ratios, respectively. The time to peak power showed a 41/16 tooth gear ratio attained peak power in -0.01 s and a 45/16 in 0.22 s compared to the 43/16. The findings of this study suggest that gear ratio choice has a significant effect on peak power production, though time to peak power output is not significantly affected. Therefore, selecting a higher gear ratio results in riders attaining higher power outputs without reducing their start time.

  12. Short-Term Electrical Peak Demand Forecasting in a Large Government Building Using Artificial Neural Networks

    Directory of Open Access Journals (Sweden)

    Jason Grant

    2014-03-01

    Full Text Available The power output capacity of a local electrical utility is dictated by its customers’ cumulative peak-demand electrical consumption. Most electrical utilities in the United States maintain peak-power generation capacity by charging for end-use peak electrical demand; thirty to seventy percent of an electric utility’s bill. To reduce peak demand, a real-time energy monitoring system was designed, developed, and implemented for a large government building. Data logging, combined with an application of artificial neural networks (ANNs, provides short-term electrical load forecasting data for controlled peak demand. The ANN model was tested against other forecasting methods including simple moving average (SMA, linear regression, and multivariate adaptive regression splines (MARSplines and was effective at forecasting peak building electrical demand in a large government building sixty minutes into the future. The ANN model presented here outperformed the other forecasting methods tested with a mean absolute percentage error (MAPE of 3.9% as compared to the SMA, linear regression, and MARSplines MAPEs of 7.7%, 17.3%, and 7.0% respectively. Additionally, the ANN model realized an absolute maximum error (AME of 8.2% as compared to the SMA, linear regression, and MARSplines AMEs of 26.2%, 45.1%, and 22.5% respectively.

  13. The Doppler peaks from a generic defect

    CERN Document Server

    Magueijo, J

    1996-01-01

    We investigate which of the exotic Doppler peak features found for textures and cosmic strings are generic novelties pertaining to defects. We find that the ``out of phase'' texture signature is an accident. Generic defects, when they generate a secondary peak structure similar to inflation, apply to it an additive shift. It is not necessary for this shift to be ``out of phase''. We also show which factors are responsible for the absence of secondary oscillations found for cosmic strings. Within this general analysis we finally consider the conditions under which topological defects and inflation can be confused. It is argued that only \\Omega=1 inflation and a defect with a horizon size coherence length have a chance to be confused. Any other inflationary or defect model always differ distinctly. (To appear in the proceedings of the XXXIth Moriond meeting, ``Microwave Background Anisotropies'')

  14. Solar Cycle 24: is the peak coming?

    CERN Document Server

    Sello, Stefano

    2012-01-01

    Solar cycle activity forecasting, mainly its magnitude and timing, is an essential issue for numerous scientific and technological applications: in fact, during an active solar period, many strong eruptions occur on the Sun with increasing frequency, such as flares, coronal mass ejections, high velocity solar wind photons and particles, which can severely affect the Earth's ionosphere and the geomagnetic field, with impacts on the low atmosphere. Thus it is very important to develop reliable solar cycle prediction methods for the incoming solar activity. The current solar cycle 24 appeared unusual from many points of view: an unusually extended minimum period, and a global low activity compared to those of the previous three or four cycles. Currently, there are many different evidences that the peak in the northern hemisphere already occurred at 2011.6 but not yet in the southern hemisphere. In this brief note we update the peak prediction and its timing, based on the most recent observations.

  15. Peak oil, food systems, and public health.

    Science.gov (United States)

    Neff, Roni A; Parker, Cindy L; Kirschenmann, Frederick L; Tinch, Jennifer; Lawrence, Robert S

    2011-09-01

    Peak oil is the phenomenon whereby global oil supplies will peak, then decline, with extraction growing increasingly costly. Today's globalized industrial food system depends on oil for fueling farm machinery, producing pesticides, and transporting goods. Biofuels production links oil prices to food prices. We examined food system vulnerability to rising oil prices and the public health consequences. In the short term, high food prices harm food security and equity. Over time, high prices will force the entire food system to adapt. Strong preparation and advance investment may mitigate the extent of dislocation and hunger. Certain social and policy changes could smooth adaptation; public health has an essential role in promoting a proactive, smart, and equitable transition that increases resilience and enables adequate food for all.

  16. Excursion set peaks: the role of shear

    CERN Document Server

    Castorina, Emanuele; Hahn, Oliver; Sheth, Ravi K

    2016-01-01

    Recent analytical work on the modelling of dark halo abundances and clustering has demonstrated the advantages of combining the excursion set approach with peaks theory. We extend these ideas and introduce a model of excursion set peaks that incorporates the role of initial tidal effects or shear in determining the gravitational collapse of dark haloes. The model -- in which the critical density threshold for collapse depends on the tidal influences acting on protohaloes -- is well motivated from ellipsoidal collapse arguments and is also simple enough to be analytically tractable. We show that the predictions of this model are in very good agreement with measurements of the halo mass function and traditional scale dependent halo bias in N-body simulations across a wide range of masses and redshift. The presence of shear in the collapse threshold means that halo bias is naturally predicted to be nonlocal, and that protohalo densities at fixed mass are naturally predicted to have Lognormal-like distributions. ...

  17. Peak picking and the assessment of separation performance in two-dimensional high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Guiochon, Georges A [ORNL; Shalliker, R. Andrew [University of Western Sydney, Australia

    2010-01-01

    An algorithm was developed for 2DHPLC that automated the process of peak recognition, measuring their retention times, and then subsequently plotting the information in a two-dimensional retention plane. Following the recognition of peaks, the software then performed a series of statistical assessments of the separation performance, measuring for example, correlation between dimensions, peak capacity and the percentage of usage of the separation space. Peak recognition was achieved by interpreting the first and second derivatives of each respective one-dimensional chromatogram to determine the 1D retention times of each solute and then compiling these retention times for each respective fraction 'cut'. Due to the nature of comprehensive 2DHPLC adjacent cut fractions may contain peaks common to more than one cut fraction. The algorithm determined which components were common in adjacent cuts and subsequently calculated the peak maximum profile by interpolating the space between adjacent peaks. This algorithm was applied to the analysis of a two-dimensional separation of an apple flesh extract separated in a first dimension comprising a cyano stationary phase and an aqueous/THF mobile phase as the first dimension and a second dimension comprising C18-Hydro with an aqueous/MeOH mobile phase. A total of 187 peaks were detected.

  18. Reducing Peak Power in Automated Weapon Laying

    Science.gov (United States)

    2016-02-01

    The values used are determined based on a number of factors including available power, maximum motor speed , maximum safe slewing speeds , peak...METHODS, ASSUMPTIONS, AND PROCEDURES Conventions and Variable Definitions Before describing the formulas to solve the aforementioned problems, it is...These two formulas are set equal to each other in equation 9 and then solved for t2 in equation 10. Note that the negative value of α2 results in a

  19. Hanford Site peak gust wind speeds

    Energy Technology Data Exchange (ETDEWEB)

    Ramsdell, J.V.

    1998-09-29

    Peak gust wind data collected at the Hanford Site since 1945 are analyzed to estimate maximum wind speeds for use in structural design. The results are compared with design wind speeds proposed for the Hanford Site. These comparisons indicate that design wind speeds contained in a January 1998 advisory changing DOE-STD-1020-94 are excessive for the Hanford Site and that the design wind speeds in effect prior to the changes are still appropriate for the Hanford Site.

  20. Derivatization in gas chromatographic determination of phenol and aniline traces in aqueous media

    Science.gov (United States)

    Gruzdev, I. V.; Zenkevich, I. G.; Kondratenok, B. M.

    2015-06-01

    Substituted anilines and phenols are the most common hydrophilic organic environmental toxicants. The principles of gas chromatographic determination of trace amounts of these compounds in aqueous media at concentrations extractive preconcentration and selective chromatographic detection. Among the known reactions, this condition is best met by electrophilic halogenation of compounds at the aromatic moiety. The bibliography includes 177 references.

  1. Multiple chromatographic fingerprinting and its application to the quality control of herbal medicines

    Energy Technology Data Exchange (ETDEWEB)

    Fan Xiaohui [Pharmaceutical Informatics Institute, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310027 (China); Cheng Yiyu [Pharmaceutical Informatics Institute, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310027 (China)]. E-mail: chengyy@zju.edu.cn; Ye Zhengliang [Pharmaceutical Informatics Institute, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310027 (China); Lin Ruichao [National Institute for the Control of Pharmaceutical and Biological Products, Beijing 100050 (China); Qian Zhongzhi [Committee of Chinese Pharmacopoeia, Beijing 100061 (China)

    2006-01-12

    Recently, chromatographic fingerprinting has become one of the most powerful approaches to quality control of herbal medicines. However, the performance of reported chromatographic fingerprinting constructed by single chromatogram sometimes turns out to be inadequate for complex herbal medicines, such as multi-herb botanical drug products. In this study, multiple chromatographic fingerprinting, which consists of more than one chromatographic fingerprint and represents the whole characteristics of chemical constitutions of the complex medicine, is proposed as a potential strategy in this complicated case. As a typical example, a binary chromatographic fingerprinting of 'Danshen Dropping Pill' (DSDP), the best-sold traditional Chinese medicine in China, was developed. First, two HPLC fingerprints that, respectively, represent chemical characteristics of depsides and saponins of DSDP were developed, which were used to construct binary chromatographic fingerprints of DSDP. Moreover, the authentication and validation of the binary fingerprints were performed. Then, a data-level information fusion method was employed to capture the chemical information encoded in two chromatographic fingerprints. Based on the fusion results, the lot-to-lot consistency and frauds can be determined either using similarity measure or by chemometrics approach. The application of binary chromatographic fingerprinting to consistency assessment and frauds detection of DSDP clearly demonstrated that the proposed method was a powerful approach to quality control of complex herbal medicines.

  2. Liquid heat capacity lasers

    Science.gov (United States)

    Comaskey, Brian J.; Scheibner, Karl F.; Ault, Earl R.

    2007-05-01

    The heat capacity laser concept is extended to systems in which the heat capacity lasing media is a liquid. The laser active liquid is circulated from a reservoir (where the bulk of the media and hence waste heat resides) through a channel so configured for both optical pumping of the media for gain and for light amplification from the resulting gain.

  3. Visual attention capacity

    DEFF Research Database (Denmark)

    Habekost, Thomas; Starrfelt, Randi

    2009-01-01

    to patient testing, and review existing TVA-based patient studies organized by lesion anatomy. Lesions in three anatomical regions affect visual capacity: The parietal lobes, frontal cortex and basal ganglia, and extrastriate cortex. Visual capacity thus depends on large, bilaterally distributed anatomical...

  4. METing SUSY on the Z peak

    Energy Technology Data Exchange (ETDEWEB)

    Barenboim, G.; Bernabeu, J.; Vives, O. [Universitat de Valencia, Departament de Fisica Teorica, Burjassot (Spain); Universitat de Valencia-CSIC, Parc Cientific U.V., IFIC, Paterna (Spain); Mitsou, V.A.; Romero, E. [Universitat de Valencia-CSIC, Parc Cientific U.V., IFIC, Paterna (Spain)

    2016-02-15

    Recently the ATLAS experiment announced a 3 σ excess at the Z-peak consisting of 29 pairs of leptons together with two or more jets, E{sub T}{sup miss} > 225 GeV and HT > 600 GeV, to be compared with 10.6 ± 3.2 expected lepton pairs in the Standard Model. No excess outside the Z-peak was observed. By trying to explain this signal with SUSY we find that only relatively light gluinos, m{sub g} or similar 400 GeV decaying predominantly to Z-boson plus a light gravitino, such that nearly every gluino produces at least one Z-boson in its decay chain, could reproduce the excess. We construct an explicit general gauge mediation model able to reproduce the observed signal overcoming all the experimental limits. Needless to say, more sophisticated models could also reproduce the signal, however, any model would have to exhibit the following features: light gluinos, or heavy particles with a strong production cross section, producing at least one Z-boson in its decay chain. The implications of our findings for the Run II at LHC with the scaling on the Z peak, as well as for the direct search of gluinos and other SUSY particles, are pointed out. (orig.)

  5. Value for railway capacity

    DEFF Research Database (Denmark)

    Sameni, Melody Khadem; Preston, John M.

    2012-01-01

    Growth in rail traffic has not been matched by increases in railway infrastructure. Given this capacity challenge and the current restrictions on public spending, the allocation and the utilization of existing railway capacity are more important than ever. Great Britain has had the greatest growth...... in rail passenger kilometers of European countries since 1996. However, costs are higher and efficiency is lower than European best practice. This paper provides an innovative methodology for assessing the efficiency of passenger operators in capacity utilization. Data envelopment analysis (DEA) is used...... to analyze the efficiency of operators in transforming inputs of allocated capacity of infrastructure and franchise payments into valuable passenger service outputs while avoiding delays. By addressing operational and economic aspects of capacity utilization simultaneously, the paper deviates from existing...

  6. Model-based design of peptide chromatographic purification processes.

    Science.gov (United States)

    Gétaz, David; Stroehlein, Guido; Butté, Alessandro; Morbidelli, Massimo

    2013-04-05

    In this work we present a general procedure for the model-based optimization of a polypeptide crude mixture purification process through its application to a case of industrial relevance. This is done to show how much modeling can be beneficial to optimize complex chromatographic processes in the industrial environment. The target peptide elution profile was modeled with a two sites adsorption equilibrium isotherm exhibiting two inflection points. The variation of the isotherm parameters with the modifier concentration was accounted for. The adsorption isotherm parameters of the target peptide were obtained by the inverse method. The elution of the impurities was approximated by lumping them into pseudo-impurities and by regressing their adsorption isotherm parameters directly as a function of the corresponding parameters of the target peptide. After model calibration and validation by comparison with suitable experimental data, Pareto optimizations of the process were carried out so as to select the optimal batch process.

  7. Measurement uncertainty of liquid chromatographic analyses visualized by Ishikawa diagrams.

    Science.gov (United States)

    Meyer, Veronika R

    2003-09-01

    Ishikawa, or cause-and-effect diagrams, help to visualize the parameters that influence a chromatographic analysis. Therefore, they facilitate the set up of the uncertainty budget of the analysis, which can then be expressed in mathematical form. If the uncertainty is calculated as the Gaussian sum of all uncertainty parameters, it is necessary to quantitate them all, a task that is usually not practical. The other possible approach is to use the intermediate precision as a base for the uncertainty calculation. In this case, it is at least necessary to consider the uncertainty of the purity of the reference material in addition to the precision data. The Ishikawa diagram is then very simple, and so is the uncertainty calculation. This advantage is given by the loss of information about the parameters that influence the measurement uncertainty.

  8. Chromatographic Analysis of Inks for Forensic Science Applications.

    Science.gov (United States)

    Tebbett, I R

    1991-12-01

    This article reviews the use of chromatography for the separation and comparison of ink components. Thin layer chromatography (TLC) is the standard chromatographic procedure presently employed for the comparison of inks. Thin layer chromatography systems are described for the separation of different types of ink. The greater sensitivity and resolution offered by high performance liquid chromatography (HPLC) make it an attractive alternative to TLC for ink analysis, and recent work in this field is also outlined. Both techniques have been used for the measurement of changes occurring in the composition of inks with time, as a means of determining the age of an ink. Related analytical techniques, recent research, and future trends in ink analysis are also described. Copyright © 1991 Central Police University.

  9. Chromatographic separation of radioactive noble gases from xenon

    CERN Document Server

    Akerib, D S; Bai, X; Bailey, A J; Balajthy, J; Beltrame, P; Bernard, E P; Bernstein, A; Biesiadzinski, T P; Boulton, E M; Bramante, R; Cahn, S B; Carmona-Benitez, M C; Chan, C; Chiller, A A; Chiller, C; Coffey, T; Currie, A; Cutter, J E; Davison, T J R; Dobi, A; Dobson, J E Y; Druszkiewicz, E; Edwards, B N; Faham, C H; Fiorucci, S; Gaitskell, R J; Gehman, V M; Ghag, C; Gibson, K R; Gilchriese, M G D; Hall, C R; Hanhardt, M; Haselschwardt, S J; Hertel, S A; Hogan, D P; Horn, M; Huang, D Q; Ignarra, C M; Ihm, M; Jacobsen, R G; Ji, W; Kamdin, K; Kazkaz, K; Khaitan, D; Knoche, R; Larsen, N A; Lee, C; Lenardo, B G; Lesko, K T; Lindote, A; Lopes, M I; Manalaysay, A; Mannino, R L; Marzioni, M F; McKinsey, D N; Mei, D -M; Mock, J; Moongweluwan, M; Morad, J A; Murphy, A St J; Nehrkorn, C; Nelson, H N; Neves, F; O'Sullivan, K; Oliver-Mallory, K C; Palladino, K J; Pease, E K; Pech, K; Phelps, P; Reichhart, L; Rhyne, C; Shaw, S; Shutt, T A; Silva, C; Solovov, V N; Sorensen, P; Stephenson, S; Sumner, T J; Szydagis, M; Taylor, D J; Taylor, W; Tennyson, B P; Terman, P A; Tiedt, D R; To, W H; Tripathi, M; Tvrznikova, L; Uvarov, S; Verbus, J R; Webb, R C; White, J T; Whitis, T J; Witherell, M S; Wolfs, F L H; Yazdani, K; Young, S K; Zhang, C

    2016-01-01

    The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid xenon typically contains trace amounts of the noble radioactive isotopes $^{85}$Kr and $^{39}$Ar that are not removed by the {\\em in situ} gas purification system. The decays of these isotopes at concentrations typical of research-grade xenon would be a dominant background for a WIMP search exmperiment. To remove these impurities from the liquid xenon, a chromatographic separation system based on adsorption on activated charcoal was built. 400\\,kg of xenon was processed, reducing the average concentration of krypton from 130\\,ppb to 3.5\\,ppt as measured by a cold-trap assisted mass spectroscopy system. A 50 kg batch spiked to 0.001 g/g of krypton was processed twice and reduced to an upper limit of 0.2 ppt.

  10. Application of monolithic chromatographic supports in virus research.

    Science.gov (United States)

    Krajacic, Mladen; Ravnikar, Maja; Štrancar, Aleš; Gutiérrez-Aguirre, Ion

    2017-05-12

    Key properties of monolithic chromatographic supports, make them suitable for separation and/or concentration of large biomolecules, especially virus particles and viral genomes. One by one, the studies that have been completed so far, contributed to the knowledge that monolith chromatography has hardly any limitation to be applied in virus research. Viruses of different sizes, possessing icosahedral structure and symmetrical morphology, as well as rod-shaped or filamentous viruses with helical structure, even enveloped ones, all of them could be successfully managed by means of monolith chromatography. Same is true for viral genomes, primarily when being distinct from other nucleic acid forms present in a host cell. This review is exclusively focused on viruses. It describes the application of monolith chromatography to different problematics within the virus research field. The reviewed achievements offer new possibilities and trigger new aspects in virology. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Fatty acids determination in Bronte pistachios by gas chromatographic method.

    Science.gov (United States)

    Pantano, Licia; Lo Cascio, Giovanni; Alongi, Angelina; Cammilleri, Gaetano; Vella, Antonio; Macaluso, Andrea; Cicero, Nicola; Migliazzo, Aldo; Ferrantelli, Vincenzo

    2016-10-01

    A gas chromatographic with flame ionization detector (GC-MS FID) method for the identification and quantification of fatty acids based on the extraction of lipids and derivatisation of free acids to form methyl esters was developed and validated. The proposed method was evaluated to a number of standard FAs, and Bronte pistachios samples were used for that purpose and to demonstrate the applicability of the proposed method. In this regard, repeatability, mean and standard deviation of the analytical procedure were calculated. The results obtained have demonstrated oleic acid as the main component of Bronte pistachios (72.2%) followed by linoleic acid (13.4%) and showed some differences in composition with respect to Tunisian, Turkish and Iranian pistachios.

  12. Resolving and quantifying overlapped chromatographic bands by transmutation

    Science.gov (United States)

    Malinowski

    2000-09-15

    A new chemometric technique called "transmutation" is developed for the purpose of sharpening overlapped chromatographic bands in order to quantify the components. The "transmutation function" is created from the chromatogram of the pure component of interest, obtained from the same instrument, operating under the same experimental conditions used to record the unresolved chromatogram of the sample mixture. The method is used to quantify mixtures containing toluene, ethylbenzene, m-xylene, naphthalene, and biphenyl from unresolved chromatograms previously reported. The results are compared to those obtained using window factor analysis, rank annihilation factor analysis, and matrix regression analysis. Unlike the latter methods, the transmutation method is not restricted to two-dimensional arrays of data, such as those obtained from HPLC/DAD, but is also applicable to chromatograms obtained from single detector experiments. Limitations of the method are discussed.

  13. CHROMATOGRAPHIC REFOLDING OF PROTEINS: MOLECULAR ACTION AND COLUMN CONTROL

    Institute of Scientific and Technical Information of China (English)

    Fangwei Wang; Yongdong Liu; Jing Chen; Zhiguo Su

    2005-01-01

    Protein expression in E. coli often results in the formation of a kind of protein aggregate called inclusion body. Conversion of the inactive protein aggregate into biologically active protein is a key step in production of recombinant products. Conventional dilution refolding technique suffers from disadvantages of low recovery and low concentration. Various chromatographic refolding techniques have been developed over the last few years. These include size-exclusion chromatography, ion exchange chromatography, hydrophobic interaction chromatography and different affinity chromatography. A successful strategy is the use of gradient elution in column control which provides a gentle and gradual change of the solution environment for the macromolecule to refold at nano-scale. The gradient refolding at column scale could minimize misfolding and aggregation which are induced by sudden change of the solution in conventional refolding operation.

  14. Extraction, chromatographic and mass spectrometric methods for lipid analysis.

    Science.gov (United States)

    Pati, Sumitra; Nie, Ben; Arnold, Robert D; Cummings, Brian S

    2016-05-01

    Lipids make up a diverse subset of biomolecules that are responsible for mediating a variety of structural and functional properties as well as modulating cellular functions such as trafficking, regulation of membrane proteins and subcellular compartmentalization. In particular, phospholipids are the main constituents of biological membranes and play major roles in cellular processes like transmembrane signaling and structural dynamics. The chemical and structural variety of lipids makes analysis using a single experimental approach quite challenging. Research in the field relies on the use of multiple techniques to detect and quantify components of cellular lipidomes as well as determine structural features and cellular organization. Understanding these features can allow researchers to elucidate the biochemical mechanisms by which lipid-lipid and/or lipid-protein interactions take place within the conditions of study. Herein, we provide an overview of essential methods for the examination of lipids, including extraction methods, chromatographic techniques and approaches for mass spectrometric analysis.

  15. A Duffing oscillator algorithm to detect the weak chromatographic signal.

    Science.gov (United States)

    Zhang, Wei; Xiang, Bing-Ren

    2007-02-28

    Based on the Duffing equation, a Duffing oscillator algorithm (DOA) to improve the signal-to-noise ratio (SNR) was presented. By simulated and experimental data sets, it was proven that the signal-to-noise ratio (SNR) of the weak signal could be greatly enhanced by this method. Using signal enhancement by DOA, this method extends the SNR of low concentrations of methylbenzene from 2.662 to 29.90 and the method can be used for quantitative analysis of methylbenzene, which are lower than detection limit of an analytical system. The Duffing oscillator algorithm (DOA) might be a promising tool to extend instrumental linear range and to improve the accuracy of trace analysis. The research enlarged the application scope of Duffing equation to chromatographic signal processing.

  16. Will peak oil accelerate carbon dioxide emissions?

    Science.gov (United States)

    Caldeira, K.; Davis, S. J.; Cao, L.

    2008-12-01

    The relative scarcity of oil suggests that oil production is peaking and will decline thereafter. Some have suggested that this represents an opportunity to reduce carbon dioxide emissions. However, in the absence of constraints on carbon dioxide emission, "peak oil" may drive a shift towards increased reliance on coal as a primary energy source. Because coal per unit energy, in the absence of carbon capture and disposal, releases more carbon dioxide to the atmosphere than oil, "peak oil" may lead to an acceleration of carbon dioxide emissions. We will never run out of oil. As oil becomes increasingly scarce, prices will rise and therefore consumption will diminish. As prices rise, other primary energy sources will become increasingly competitive with oil. The developed world uses oil primarily as a source of transportation fuels. The developing world uses oil primarily for heat and power, but the trend is towards increasing reliance on oil for transportation. Liquid fuels, including petroleum derivatives such as gasoline and diesel fuel, are attractive as transportation fuels because of their relative abundance of energy per unit mass and volume. Such considerations are especially important for the air transport industry. Today, there is little that can compete with petroleum-derived transportation fuels. Future CO2 emissions from the transportation sector largely depend on what replaces oil as a source of fuel. Some have suggested that biomass-derived ethanol, hydrogen, or electricity could play this role. Each of these potential substitutes has its own drawbacks (e.g., low power density per unit area in the case of biomass, low power density per unit volume in the case of hydrogen, and low power density per unit mass in the case of battery storage). Thus, it is entirely likely that liquefaction of coal could become the primary means by which transportation fuels are produced. Since the burning of coal produces more CO2 per unit energy than does the burning of

  17. Preparation of a novel hydrophobic affinity cryogel for adsorption of lipase and its utilization as a chromatographic adsorbent for fast protein liquid chromatography.

    Science.gov (United States)

    Ünlüer, Özlem Biçen; Özcan, Ayça; Uzun, Lokman

    2014-01-01

    In this study, we have prepared a hydrophobic cryogel for the chromatographic separation of lipase from its aqueous solutions including single protein and protein mixture and also Yarrowia lipolytica cell extract. N-methacryloyl-(l)-phenylalanine methyl ester was used as a monomer to provide the hydrophobic character to the prepared cryogels. The highest adsorption capacity was observed at pH 5.0 at 0.5 mL min(-1) flow rate. The chromatographic separation of lipase was achieved from a binary mixture of lipase:bovine serum albumin (BSA) and lipase:lysozyme, and was also achieved from triple-mixture of lipase:lysozyme:BSA by using fast protein liquid chromatography. Finally, lipase purification was performed from Yarrowia lipolytica cell extract used as a natural source. These studies have shown that the hydrophobic cryogel has good chromatographic performance for the separation and purification of lipase not only from aqueous solution, but also from cell extract as a natural source of lipase. © 2013 American Institute of Chemical Engineers.

  18. [Preparation of an agglomerated ion chromatographic stationary phase with 2,3-ionene and its application in SO4(2-) analysis].

    Science.gov (United States)

    Wang, Muhua; Liu, Junwei; Huang, Zhongping; Zhang, Jiajie; Zhu, Yan

    2015-07-01

    The poly-electrolyte cation functional group of 2,3-ionene was synthesized with tetramethyl ethylenediamine and 1,3-dibromopropane as the raw materials. Multiporous polystyrene-divinylbenzene microsphere particles (PS-DVB) were produced by swelling method with polystyrene as seeds and sulfonated. Then the 2,3-ionene was bonded on the sulfonated multi-porous polystyrene-divinylbenzene microsphere particles by agglomeration to get the agglomerative ion-exchange stationary phase. After optimizing the synthetic conditions, the new stationary phase was characterized by the techniques including scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR) and elemental analysis. The chromatographic column was packed by slurry method and applied in the analysis of SO4(2-) with a conductivity detector. SO4(2-) and other six common anions including F-, Cl-, NO2(-), Br-, NO3(-), PO4(3-), were separated and analyzed rapidly on the self-regulating chromatographic column within 8 min. The linear range was from 0.5 to 50 mg/L with correlation coefficient (r) of 0.9992. The LOD was 0.04 mg/L with S/N of 3. The relative standard deviations (RSDs, n = 6) were 2.4% and 3.1% for the peak area and retention time, respectively. The recoveries were between 99.2% and 101.8%. The retention times of SO4(2-) did not change significantly after long time use of the self-regulating chromatographic column. The self-regulating chromatographic column is suitable for the detection of SO4(2-) in complex matrix samples.

  19. Improvement of gas chromatographic analysis for organic acids and ...

    African Journals Online (AJOL)

    Yomi

    2010-08-27

    Aug 27, 2010 ... 3Fermentation Research Center for Value Added Agricultural ... short retention time and fair recognition peak of the compounds were obtained under the following ... are reutilized and acetone, butanol and ethanol are pro-.

  20. Aerobic exercise capacity at long-term follow-up after paediatric allogeneic haematopoietic SCT

    DEFF Research Database (Denmark)

    Mathiesen, S; Uhlving, H H; Buchvald, F

    2014-01-01

    Peak oxygen uptake (VO2peak), a measure of aerobic exercise capacity, predicts mortality and morbidity in healthy and diseased individuals. Our aim was to determine VO2peak years after paediatric allogeneic haematopoietic SCT (HSCT) and to identify associations with baseline patient and donor cha...

  1. Vedr.: Military capacity building

    DEFF Research Database (Denmark)

    Larsen, Josefine Kühnel; Struwe, Lars Bangert

    2013-01-01

    Military capacity building has increasingly become an integral part of Danish defence. Military capacity is a new way of thinking Danish defence and poses a new set of challenges and opportunities for the Danish military and the Political leadership. On the 12th of december, PhD. Candidate Josefine...... Kühnel Larsen and researcher Lars Bangert Struwe of CMS had organized a seminar in collaboration with Royal Danish Defense Colleg and the East African Security Governance Network. The seminar focused on some of the risks involved in Military capacity building and how these risks are dealt with from...

  2. Vedr.: Military capacity building

    DEFF Research Database (Denmark)

    Larsen, Josefine Kühnel; Struwe, Lars Bangert

    2013-01-01

    Kühnel Larsen and researcher Lars Bangert Struwe of CMS had organized a seminar in collaboration with Royal Danish Defense Colleg and the East African Security Governance Network. The seminar focused on some of the risks involved in Military capacity building and how these risks are dealt with from......Military capacity building has increasingly become an integral part of Danish defence. Military capacity is a new way of thinking Danish defence and poses a new set of challenges and opportunities for the Danish military and the Political leadership. On the 12th of december, PhD. Candidate Josefine...

  3. Improving the productivity of a multidimensional chromatographic preparative system by collecting pure chemicals after each of three chromatographic dimensions.

    Science.gov (United States)

    Sciarrone, Danilo; Pantò, Sebastiano; Donato, Paola; Mondello, Luigi

    2016-12-02

    The enhanced sample collection capability of a heart-cutting three-dimensional GC-prep system is reported. In its original configuration, a highly pure component can be usually collected after the last (3D) column outlet by means of a dedicated preparative station. The latter is located after the last chromatographic column, and this poses the requirement for multiple heart cuts even for those components showing satisfactory degree of purity after the first (or second) separation dimension. The feasibility to collect pure components after each chromatographic dimension is here described, employing a three-dimension MDGC system equipped with high-temperature valves, located inside the first and second GC ovens, with the aim to improve the productivity of the collection procedure. In addition to a commercial preparative collector located at the 3D outlet, two laboratory-made collection systems were applied in the first and second dimension, reached by the effluent to be collected trough a high-temperature valve switching the heart-cut fraction between either the detector (FID), or the collector. Highly pure sesquiterpene components were collected, namely: patchouli alcohol after the first column [poly(5% diphenyl/95% dimethylsiloxane)], α-bulnesene after a second column coated with high molecular weight polyethylene glycol, and α-guaiene after an ionic-liquid based column (SLB-IL60), used as the third dimension. Purity levels ranging from 85 to 95% were achieved with an average collection recovery of 90% (n=5). The following average amounts were collected per run: 160μg for α-guaiene, 295μg for α-bulnesene, and 496μg for patchouli alcohol.

  4. Electromechanical Peak Devices of Distributed Power Generation

    Directory of Open Access Journals (Sweden)

    S. V. Konstantinova

    2011-01-01

    Full Text Available The power world crises (1973, 1979 have demonstrated that mankind entered the expensive energy epoch. More and more attitude is given to power saving problem by including renewable power sources in energy balance of the countries. The paper analyzes a power system inBelarusand a typical chart of the active load is cited in the paper. Equalization of load chart is considered as one of measures directed on provision of higher operational efficiency of power system and power saving.  This purpose can be obtained while including electromechanical peak devices of the distributed generation in the energy balance.

  5. LARAMIE PEAK WILDERNESS STUDY AREA, WYOMING.

    Science.gov (United States)

    Segerstrom, Kenneth; Weisner, R.C.

    1984-01-01

    On the basis of a mineral survey, most of the Laramie Peak Wilderness study area in Wyoming was concluded to have little promise for the occurrence of mineral or energy resources. Only three small areas in the northern part, one extending outside the study area to Esterbrook, were found to have probable mineral-resource potential for copper and lead. The geologic setting precludes the presence of fossil-fuel resources in the study area. There are no surface indications that geothermal energy could be developed within or near the study area.

  6. Forecasting peaks of seasonal influenza epidemics.

    Science.gov (United States)

    Nsoesie, Elaine; Mararthe, Madhav; Brownstein, John

    2013-06-21

    We present a framework for near real-time forecast of influenza epidemics using a simulation optimization approach. The method combines an individual-based model and a simple root finding optimization method for parameter estimation and forecasting. In this study, retrospective forecasts were generated for seasonal influenza epidemics using web-based estimates of influenza activity from Google Flu Trends for 2004-2005, 2007-2008 and 2012-2013 flu seasons. In some cases, the peak could be forecasted 5-6 weeks ahead. This study adds to existing resources for influenza forecasting and the proposed method can be used in conjunction with other approaches in an ensemble framework.

  7. Peak oil, economic growth, and wildlife conservation

    CERN Document Server

    Gates, J Edward; Czech, Brian

    2014-01-01

    The proposed book focuses on one of the most important issues affecting humankind in this century - Peak Oil or the declining availability of abundant, cheap energy-and its effects on our industrialized economy and wildlife conservation. Energy will be one of the defining issues of the 21st Century directly affecting wildlife conservation wherever energy extraction is a primary economic activity and indirectly through deepening economic recessions. Since cheap, abundant energy has been at the core of our industrial society, and has resulted in the technological advancements we enjoy today, the

  8. Particle creation by peak electric field

    CERN Document Server

    Adorno, T C; Gitman, D M

    2016-01-01

    The particle creation by the so-called peak electric field is considered. The latter field is a combination of two exponential parts, one exponentially-increasing and another exponentially-decreasing. We find exact solutions of the Dirac equation with the field under consideration with appropriate asymptotic conditions and calculate all the characteristics of particle creation effect, in particular, differential mean numbers of created particle, total number of created particles, and the probability for a vacuum to remain a vacuum. Characteristic asymptotic regimes are discussed in detail and a comparison with the pure asymptotically decaying field is considered.

  9. Particle creation by peak electric field

    Energy Technology Data Exchange (ETDEWEB)

    Adorno, T.C. [Tomsk State University, Department of Physics, Tomsk (Russian Federation); Gavrilov, S.P. [Tomsk State University, Department of Physics, Tomsk (Russian Federation); Herzen State Pedagogical University of Russia, Department of General and Experimental Physics, St. Petersburg (Russian Federation); Gitman, D.M. [Tomsk State University, Department of Physics, Tomsk (Russian Federation); P. N. Lebedev Physical Institute, Moscow (Russian Federation); University of Sao Paulo, Institute of Physics, CP 66318, Sao Paulo, SP (Brazil)

    2016-08-15

    The particle creation by the so-called peak electric field is considered. The latter field is a combination of two exponential parts, one exponentially increasing and another exponentially decreasing. We find exact solutions of the Dirac equation with the field under consideration with appropriate asymptotic conditions and calculate all the characteristics of particle creation effect, in particular, differential mean numbers of created particle, total number of created particles, and the probability for a vacuum to remain a vacuum. Characteristic asymptotic regimes are discussed in detail and a comparison with the pure asymptotically decaying field is considered. (orig.)

  10. Beyond the Peak - Tactile Temporal Discrimination Does Not Correlate with Individual Peak Frequencies in Somatosensory Cortex.

    Science.gov (United States)

    Baumgarten, Thomas J; Schnitzler, Alfons; Lange, Joachim

    2017-01-01

    The human sensory systems constantly receive input from different stimuli. Whether these stimuli are integrated into a coherent percept or segregated and perceived as separate events, is critically determined by the temporal distance of the stimuli. This temporal distance has prompted the concept of temporal integration windows or perceptual cycles. Although this concept has gained considerable support, the neuronal correlates are still discussed. Studies suggested that neuronal oscillations might provide a neuronal basis for such perceptual cycles, i.e., the cycle lengths of alpha oscillations in visual cortex and beta oscillations in somatosensory cortex might determine the length of perceptual cycles. Specifically, recent studies reported that the peak frequency (the frequency with the highest spectral power) of alpha oscillations in visual cortex correlates with subjects' ability to discriminate two visual stimuli. In the present study, we investigated whether peak frequencies in somatosensory cortex might serve as the correlate of perceptual cycles in tactile discrimination. Despite several different approaches, we were unable to find a significant correlation between individual peak frequencies in the alpha- and beta-band and individual discrimination abilities. In addition, analysis of Bayes factor provided evidence that peak frequencies and discrimination thresholds are unrelated. The results suggest that perceptual cycles in the somatosensory domain are not necessarily to be found in the peak frequency, but in other frequencies. We argue that studies based solely on analysis of peak frequencies might thus miss relevant information.

  11. PeakVizor: Visual Analytics of Peaks in Video Clickstreams from Massive Open Online Courses.

    Science.gov (United States)

    Chen, Qing; Chen, Yuanzhe; Liu, Dongyu; Shi, Conglei; Wu, Yingcai; Qu, Huamin

    2016-10-01

    Massive open online courses (MOOCs) aim to facilitate open-access and massive-participation education. These courses have attracted millions of learners recently. At present, most MOOC platforms record the web log data of learner interactions with course videos. Such large amounts of multivariate data pose a new challenge in terms of analyzing online learning behaviors. Previous studies have mainly focused on the aggregate behaviors of learners from a summative view; however, few attempts have been made to conduct a detailed analysis of such behaviors. To determine complex learning patterns in MOOC video interactions, this paper introduces a comprehensive visualization system called PeakVizor. This system enables course instructors and education experts to analyze the "peaks" or the video segments that generate numerous clickstreams. The system features three views at different levels: the overview with glyphs to display valuable statistics regarding the peaks detected; the flow view to present spatio-temporal information regarding the peaks; and the correlation view to show the correlation between different learner groups and the peaks. Case studies and interviews conducted with domain experts have demonstrated the usefulness and effectiveness of PeakVizor, and new findings about learning behaviors in MOOC platforms have been reported.

  12. Peak heart rates at extreme altitudes

    DEFF Research Database (Denmark)

    Lundby, C; Van Hall, Gerrit

    2001-01-01

    We have measured maximal heart rate during a graded maximal bicycle exercise test to exhaustion in five healthy climbers before and during an expedition to Mt. Everest. Maximal heart rates at sea level were 186 (177-204) beats/min(-1) at sea level and 170 (169-182) beats/min(-1) with acute hypoxia....... After 1, 4 and 6 weeks of acclimatization to 5400 m, maximal heart rates were 155 (135-182), 158 (144-182), and 155 (140-183) beats/min(-1), respectively. Heart rates of two of the climbers were measured during their attempt to reach the summit of Mt. Everest without the use of supplemental oxygen....... The peak heart rates at 8,750 m for the two climbers were 142 and 144 beats/min(-1), which were similar to their maximal heart rates during exhaustive bicycle exercise at 5,400 m, the values being 144 and 148 beats/min(-1), respectively. The peak heart rates at 8,750 m are in agreement with other field...

  13. Equivalence Principle and the Baryon Acoustic Peak

    CERN Document Server

    Baldauf, Tobias; Simonović, Marko; Zaldarriaga, Matias

    2015-01-01

    We study the dominant effect of a long wavelength density perturbation $\\delta(\\lambda_L)$ on short distance physics. In the non-relativistic limit, the result is a uniform acceleration, fixed by the equivalence principle, and typically has no effect on statistical averages due to translational invariance. This same reasoning has been formalized to obtain a "consistency condition" on the cosmological correlation functions. In the presence of a feature, such as the acoustic peak at $l_{\\rm BAO}$, this naive expectation breaks down for $\\lambda_Lpeak, and is calculable to all orders in the long modes. This can be used to improve the result of perturbative calculations - a technique known as "infra-red resummation"- and is explicitly applied to the one-loop calculation of power spectrum. Finally, the success of BAO reconstruction schemes is argue...

  14. Microwave peak absorption frequency of liquid

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Microwave-assisted extraction is a new effective method which has practical ap-plications in many fields. Microwave heating is one of its physical mechanisms,and it also has the characteristic of selectivity. When the applied microwave fre-quency equals a certain absorption frequency of the material (or specific compo-nent),the material will intensively absorb microwave energy. This is also known as resonant absorption,and the frequency is called the peak absorption frequency which depends on the physical structure of the material. In this work,dynamic hy-drogen bond energy was included in molecular activation energy; with the liquid cell model,the expression of interaction energy between dipolar molecules was derived. The rotational relaxation time was gotten from the Eyring viscosity formula. Then based on the relationship between dielectric dissipation coefficient and re-laxation time,the expression of microwave peak absorption frequency as a func-tion of the material physical structure,rotational inertia and electrical dipole mo-ment of molecules was established. These theoretical formulas were applied to water and benzene,and the calculated results agree fairly well with the experi-mental data. This work can not only deepen the study of the interaction between microwave and material,but also provide a possible guide for the experiment of microwave-assisted extraction.

  15. Microwave peak absorption frequency of liquid

    Institute of Scientific and Technical Information of China (English)

    HAN GuangZe; CHEN MingDong

    2008-01-01

    Microwave-assisted extraction is a new effective method which has practical ap-plications in many fields. Microwave heating is one of its physical mechanisms, and it also has the characteristic of selectivity. When the applied microwave fre-quency equals a certain absorption frequency of the material (or specific compo-nent), the material will intensively absorb microwave energy. This is also known as resonant absorption, and the frequency is called the peak absorption frequency which depends on the physical structure of the material. In this work, dynamic hy-drogen bond energy was included in molecular activation energy; with the liquid cell model, the expression of interaction energy between dipolar molecules was derived. The rotational relaxation time was gotten from the Eyring viscosity formula. Then based on the relationship between dielectric dissipation coefficient and re-laxation time, the expression of microwave peak absorption frequency as a func-tion of the material physical structure, rotational inertia and electrical dipole mo-ment of molecules was established. These theoretical formulas were applied to water and benzene, and the calculated results agree fairly well with the experi-mental data. This work can not only deepen the study of the interaction between microwave and material, but also provide a possible guide for the experiment of microwave-assisted extraction.

  16. CO diffusion capacity

    Energy Technology Data Exchange (ETDEWEB)

    Mielke, U.

    1979-01-01

    We measured in 287 persons the pulmonary CO diffusion capacity with the steady-state and the single breath methods, applying apnoeic periods of 4 and 10 seconds duration. The aspects methodical significance, polyclinical applicability and pathognostic relevance with respect to other approved pulmonary functional tests are discussed. Differing pulmonary diffusion capacity values found in normal persons or in patients suffering from silicosis, pulmonary fibrosis, Boeck's disease or rheumatoid arthritis, were investigated and critically evaluated.

  17. Revisiting Absorptive Capacity

    DEFF Research Database (Denmark)

    de Araújo, Ana Luiza Lara; Ulhøi, John Parm; Lettl, Christopher

    Absorptive capacity has mostly been perceived as a 'passive' outcome of R&D investments. Recently, however, a growing interest into its 'proactive' potentials has emerged. This paper taps into this development and proposes a dynamic model for conceptualizing the determinants of the complementary...... learning processes of absorptive capacity, which comprise combinative and adaptive capabilities. Drawing on survey data (n=169), the study concludes that combinative capabilities primarily enhance transformative and exploratory learning processes, while adaptive capabilities strengthen all three learning...

  18. Revisiting Absorptive Capacity

    DEFF Research Database (Denmark)

    de Araújo, Ana Luiza Lara; Ulhøi, John Parm; Lettl, Christopher

    Absorptive capacity has mostly been perceived as a 'passive' outcome of R&D investments. Recently, however, a growing interest into its 'proactive' potentials has emerged. This paper taps into this development and proposes a dynamic model for conceptualizing the determinants of the complementary...... learning processes of absorptive capacity, which comprise combinative and adaptive capabilities. Drawing on survey data (n=169), the study concludes that combinative capabilities primarily enhance transformative and exploratory learning processes, while adaptive capabilities strengthen all three learning...

  19. Method and apparatus for current-output peak detection

    Energy Technology Data Exchange (ETDEWEB)

    De Geronimo, Gianluigi

    2017-01-24

    A method and apparatus for a current-output peak detector. A current-output peak detector circuit is disclosed and works in two phases. The peak detector circuit includes switches to switch the peak detector circuit from the first phase to the second phase upon detection of the peak voltage of an input voltage signal. The peak detector generates a current output with a high degree of accuracy in the second phase.

  20. Estimation of cardiac reserve by peak power: validation and initial application of a simplified index

    Science.gov (United States)

    Armstrong, G. P.; Carlier, S. G.; Fukamachi, K.; Thomas, J. D.; Marwick, T. H.

    1999-01-01

    OBJECTIVES: To validate a simplified estimate of peak power (SPP) against true (invasively measured) peak instantaneous power (TPP), to assess the feasibility of measuring SPP during exercise and to correlate this with functional capacity. DESIGN: Development of a simplified method of measurement and observational study. SETTING: Tertiary referral centre for cardiothoracic disease. SUBJECTS: For validation of SPP with TPP, seven normal dogs and four dogs with dilated cardiomyopathy were studied. To assess feasibility and clinical significance in humans, 40 subjects were studied (26 patients; 14 normal controls). METHODS: In the animal validation study, TPP was derived from ascending aortic pressure and flow probe, and from Doppler measurements of flow. SPP, calculated using the different flow measures, was compared with peak instantaneous power under different loading conditions. For the assessment in humans, SPP was measured at rest and during maximum exercise. Peak aortic flow was measured with transthoracic continuous wave Doppler, and systolic and diastolic blood pressures were derived from brachial sphygmomanometry. The difference between exercise and rest simplified peak power (Delta SPP) was compared with maximum oxygen uptake (VO(2)max), measured from expired gas analysis. RESULTS: SPP estimates using peak flow measures correlated well with true peak instantaneous power (r = 0.89 to 0.97), despite marked changes in systemic pressure and flow induced by manipulation of loading conditions. In the human study, VO(2)max correlated with Delta SPP (r = 0.78) better than Delta ejection fraction (r = 0.18) and Delta rate-pressure product (r = 0.59). CONCLUSIONS: The simple product of mean arterial pressure and peak aortic flow (simplified peak power, SPP) correlates with peak instantaneous power over a range of loading conditions in dogs. In humans, it can be estimated during exercise echocardiography, and correlates with maximum oxygen uptake better than ejection

  1. Estimation of cardiac reserve by peak power: validation and initial application of a simplified index

    Science.gov (United States)

    Armstrong, G. P.; Carlier, S. G.; Fukamachi, K.; Thomas, J. D.; Marwick, T. H.

    1999-01-01

    OBJECTIVES: To validate a simplified estimate of peak power (SPP) against true (invasively measured) peak instantaneous power (TPP), to assess the feasibility of measuring SPP during exercise and to correlate this with functional capacity. DESIGN: Development of a simplified method of measurement and observational study. SETTING: Tertiary referral centre for cardiothoracic disease. SUBJECTS: For validation of SPP with TPP, seven normal dogs and four dogs with dilated cardiomyopathy were studied. To assess feasibility and clinical significance in humans, 40 subjects were studied (26 patients; 14 normal controls). METHODS: In the animal validation study, TPP was derived from ascending aortic pressure and flow probe, and from Doppler measurements of flow. SPP, calculated using the different flow measures, was compared with peak instantaneous power under different loading conditions. For the assessment in humans, SPP was measured at rest and during maximum exercise. Peak aortic flow was measured with transthoracic continuous wave Doppler, and systolic and diastolic blood pressures were derived from brachial sphygmomanometry. The difference between exercise and rest simplified peak power (Delta SPP) was compared with maximum oxygen uptake (VO(2)max), measured from expired gas analysis. RESULTS: SPP estimates using peak flow measures correlated well with true peak instantaneous power (r = 0.89 to 0.97), despite marked changes in systemic pressure and flow induced by manipulation of loading conditions. In the human study, VO(2)max correlated with Delta SPP (r = 0.78) better than Delta ejection fraction (r = 0.18) and Delta rate-pressure product (r = 0.59). CONCLUSIONS: The simple product of mean arterial pressure and peak aortic flow (simplified peak power, SPP) correlates with peak instantaneous power over a range of loading conditions in dogs. In humans, it can be estimated during exercise echocardiography, and correlates with maximum oxygen uptake better than ejection

  2. , Recorded at Ladron Peak, Central New Mexico

    Science.gov (United States)

    Ricketts, J. W.; Kelley, S.; Read, A. S.; Karlstrom, K. E.

    2010-12-01

    Ladron Peak, situated on the western flank of the Rio Grande rift ~30 miles NW of Socorro, NM, is composed of Precambrian granitic and metamorphic assemblages that have been faulted and uplifted during the late Tertiary formation of the rift. The area is bounded on three sides by normal faults, including the anomalously low-angle (~26°) Jeter fault to the east, which places Precambrian rocks in the footwall against Paleozoic and Mesozoic fault slivers, and mainly Cenozoic Santa Fe Group basin fill in the hanging wall. New apatite fission track (AFT) thermochronological data collected at 22 locations along the NE and SE margins of Ladron Peak give a range of ages from 10.9 ± 1.9 to 20.4 ± 8.6 Ma. Samples within the footwall include granitic and metasedimentary rocks that have mean track lengths of 13.1 to 14.1 μm; one quartzite sample has a mean track length of 12.5 μm, suggesting time in the partial annealing zone. Within the hanging wall block, new AFT ages from the Permian Bursum and Abo Formations give cooling ages of 23.1 ± 3.3 Ma. and 59.9 ± 12.4 Ma., respectively. The Bursum Formation sample, with a track length of 13.7 μm, cooled below the 110°C isotherm during the Miocene, while the Abo Formation sample, with a track length of 11.2 μm, was only partially reset prior to rift-related deformation. Mylonitized granitic and metamorphic rocks in the immediate footwall preserve dip-slip lineations that are parallel to slip on the Jeter fault. This suggests that strain associated with exhumation was recorded by both brittle and ductile deformation. Although this type of deformation is common within metamorphic core complexes in highly extended terranes, ductile normal faulting has not been recognized within the Rio Grande rift in New Mexico, though there is some suggestion of ductile deformation around Blanca Peak in the San Luis Valley in Colorado. These observations imply one or both of the following: (1) Ductile deformation at Ladron Peak was

  3. Cold Thermal Storage and Peak Load Reduction for Office Buildings in Saudi Arabia

    Institute of Scientific and Technical Information of China (English)

    Nabil Y.Abdel-Shafi; Ramzy R.Obaid; Ibrahim M.Jomoah

    2014-01-01

    This paper involves the investigations of the chilled water and ice cold thermal storage technologies along with the associated operating strategies for the air conditioning (AC) systems of the typical office buildings in Saudi Arabia, so as to reduce the electricity energy consumption during the peak load periods. In Saudi Arabia, the extensive use of AC for indoor cooling in offices composes a large proportion of the annual peak electricity demand. The very high temperatures over long summer periods, extending from May to October, and the low cost of energy are the key factors in the wide and extensive use of air conditioners in the kingdom. This intense cooling load adds up to the requirement increase in the capacity of power plants, which makes them under utilized during the off-peak periods. Thermal energy storage techniques are one of the effective demand-side energy management methods. Systems with cold storage shifts all or part of the electricity requirement from peak hours to off-peak hours to reduce demand charges and/or take advantage of off-peak rates. The investigations reveal that the cold thermal energy storage techniques are effective from both technical and economic perspectives in the reduction of energy consumption in the buildings during peak periods.

  4. Chromatographic and computational assessment of lipophilicity using sum of ranking differences and generalized pair-correlation.

    Science.gov (United States)

    Andrić, Filip; Héberger, Károly

    2015-02-06

    Lipophilicity (logP) represents one of the most studied and most frequently used fundamental physicochemical properties. At present there are several possibilities for its quantitative expression and many of them stems from chromatographic experiments. Numerous attempts have been made to compare different computational methods, chromatographic methods vs. computational approaches, as well as chromatographic methods and direct shake-flask procedure without definite results or these findings are not accepted generally. In the present work numerous chromatographically derived lipophilicity measures in combination with diverse computational methods were ranked and clustered using the novel variable discrimination and ranking approaches based on the sum of ranking differences and the generalized pair correlation method. Available literature logP data measured on HILIC, and classical reversed-phase combining different classes of compounds have been compared with most frequently used multivariate data analysis techniques (principal component and hierarchical cluster analysis) as well as with the conclusions in the original sources. Chromatographic lipophilicity measures obtained under typical reversed-phase conditions outperform the majority of computationally estimated logPs. Oppositely, in the case of HILIC none of the many proposed chromatographic indices overcomes any of the computationally assessed logPs. Only two of them (logkmin and kmin) may be selected as recommended chromatographic lipophilicity measures. Both ranking approaches, sum of ranking differences and generalized pair correlation method, although based on different backgrounds, provides highly similar variable ordering and grouping leading to the same conclusions.

  5. Peak Wind Tool for General Forecasting

    Science.gov (United States)

    Barrett, Joe H., III

    2010-01-01

    The expected peak wind speed of the day is an important forecast element in the 45th Weather Squadron's (45 WS) daily 24-Hour and Weekly Planning Forecasts. The forecasts are used for ground and space launch operations at the Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS). The 45 WS also issues wind advisories for KSC/CCAFS when they expect wind gusts to meet or exceed 25 kt, 35 kt and 50 kt thresholds at any level from the surface to 300 ft. The 45 WS forecasters have indicated peak wind speeds are challenging to forecast, particularly in the cool season months of October - April. In Phase I of this task, the Applied Meteorology Unit (AMU) developed a tool to help the 45 WS forecast non-convective winds at KSC/CCAFS for the 24-hour period of 0800 to 0800 local time. The tool was delivered as a Microsoft Excel graphical user interface (GUI). The GUI displayed the forecast of peak wind speed, 5-minute average wind speed at the time of the peak wind, timing of the peak wind and probability the peak speed would meet or exceed 25 kt, 35 kt and 50 kt. For the current task (Phase II ), the 45 WS requested additional observations be used for the creation of the forecast equations by expanding the period of record (POR). Additional parameters were evaluated as predictors, including wind speeds between 500 ft and 3000 ft, static stability classification, Bulk Richardson Number, mixing depth, vertical wind shear, temperature inversion strength and depth and wind direction. Using a verification data set, the AMU compared the performance of the Phase I and II prediction methods. Just as in Phase I, the tool was delivered as a Microsoft Excel GUI. The 45 WS requested the tool also be available in the Meteorological Interactive Data Display System (MIDDS). The AMU first expanded the POR by two years by adding tower observations, surface observations and CCAFS (XMR) soundings for the cool season months of March 2007 to April 2009. The POR was expanded

  6. Evaluation of the Influence of Sulfur-Fumigated Paeoniae Radix Alba on the Quality of Si Wu Tang by Chromatographic and Chemometric Analysis.

    Science.gov (United States)

    Pei, Ke; Cai, Hao; Duan, Yu; Qiao, Feng-Xian; Tu, Si-Cong; Liu, Xiao; Wang, Xiao-Li; Song, Xiao-Qing; Fan, Kai-Lei; Cai, Bao-Chang

    2016-01-01

    An accurate and reliable method of high-performance liquid chromatographic fingerprint combining with multi-ingredient determination was developed and validated to evaluate the influence of sulfur-fumigated Paeoniae Radix Alba on the quality and chemical constituents of Si Wu Tang. Multivariate data analysis including hierarchical cluster analysis and principal component analysis, which integrated with high-performance liquid chromatographic fingerprint and multi-ingredient determination, was employed to evaluate Si Wu Tang in a more objective and scientific way. Interestingly, in this paper, a total of 37 and 36 peaks were marked as common peaks in ten batches of Si Wu Tang containing sun-dried Paeoniae Radix Alba and ten batches of Si Wu Tang containing sulfur-fumigated Paeoniae Radix Alba, respectively, which indicated the changed fingerprint profile of Si Wu Tang when containing sulfur-fumigated herb. Furthermore, the results of simultaneous determination for multiple ingredients showed that the contents of albiflorin and paeoniflorin decreased significantly (P < 0.01) and the contents of gallic acid and Z-ligustilide decreased to some extent at the same time when Si Wu Tang contained sulfur-fumigated Paeoniae Radix Alba. Therefore, sulfur-fumigation processing may have great influence on the quality of Chinese herbal prescription.

  7. A new method for the determination of peak distribution across a two-dimensional separation space for the identification of optimal column combinations.

    Science.gov (United States)

    Leonhardt, Juri; Teutenberg, Thorsten; Buschmann, Greta; Gassner, Oliver; Schmidt, Torsten C

    2016-11-01

    For the identification of the optimal column combinations, a comparative orthogonality study of single columns and columns coupled in series for the first dimension of a microscale two-dimensional liquid chromatographic approach was performed. In total, eight columns or column combinations were chosen. For the assessment of the optimal column combination, the orthogonality value as well as the peak distributions across the first and second dimension was used. In total, three different methods of orthogonality calculation, namely the Convex Hull, Bin Counting, and Asterisk methods, were compared. Unfortunately, the first two methods do not provide any information of peak distribution. The third method provides this important information, but is not optimal when only a limited number of components are used for method development. Therefore, a new concept for peak distribution assessment across the separation space of two-dimensional chromatographic systems and clustering detection was developed. It could be shown that the Bin Counting method in combination with additionally calculated histograms for the respective dimensions is well suited for the evaluation of orthogonality and peak clustering. The newly developed method could be used generally in the assessment of 2D separations. Graphical Abstract ᅟ.

  8. Changes in peak fat oxidation in response to different doses of endurance training

    DEFF Research Database (Denmark)

    Larsen, Mads Rosenkilde; Reichkendler, M H; Auerbach, P;

    2015-01-01

    The effect of different doses of endurance training on the capacity to oxidize fat during exercise in sedentary, overweight men and assessment of variables associated with changes in peak fat oxidation (PFO) were evaluated. Young, sedentary, overweight men were randomized to either the high......, and mitochondrial oxphos complexes II-V increased similarly in MOD and HIGH. Stepwise multiple linear regression analysis with backward elimination of individual variables correlated with changes in PFO revealed increases in cycling efficiency, FFM, and VO2 peak as the remaining associated variables. In conclusion...

  9. OpenSlice: Quantitative data sharing from HyperPeaks to global ion chromatograms (GICs).

    Science.gov (United States)

    Askenazi, Manor; Fenyö, David

    2016-09-01

    Data sharing in the field of MS has advanced greatly thanks to innovations such as the standardized formats, data repositories, and publications guidelines. However, there is currently no data sharing mechanism that enables real-time data browsing and deep linking on a large scale: unrestricted data access (particularly at the quantitative level) ultimately requires the user to download a local copy of the relevant data files (e.g., in order to generate extracted ion chromatograms [XICs]). In this technical resource, we present a set of technologies (collectively termed OpenSlice) that enable the user to quantitatively query hundreds of hours of proteomics discovery data (i.e., nontargeted acquisition) in real time: the user is able to effectively generate XICs for arbitrary masses on the fly and across the entire dataset (so-called global ion chromatograms), interacting with the results through a very intuitive browser-based interface. A key design consideration underlying the OpenSlice approach is the notion that every aspect of the acquired data must be accessible through a RESTful uniform resource locator based application programming interface, up to and including individual chromatographic peaks (hence HyperPeaks). A publicly accessible demonstration of this technology based on the Clinical Proteomics Tumor Analysis Consortium CompRef dataset is made available at http://compref.fenyolab.org. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Peak Electric Load Relief in Northern Manhattan

    Directory of Open Access Journals (Sweden)

    Hildegaard D. Link

    2014-08-01

    Full Text Available The aphorism “Think globally, act locally,” attributed to René Dubos, reflects the vision that the solution to global environmental problems must begin with efforts within our communities. PlaNYC 2030, the New York City sustainability plan, is the starting point for this study. Results include (a a case study based on the City College of New York (CCNY energy audit, in which we model the impacts of green roofs on campus energy demand and (b a case study of energy use at the neighborhood scale. We find that reducing the urban heat island effect can reduce building cooling requirements, peak electricity loads stress on the local electricity grid and improve urban livability.

  11. Tim Peake and Britain's road to space

    CERN Document Server

    Seedhouse, Erik

    2017-01-01

    This book puts the reader in the flight suit of Britain’s first male astronaut, Tim Peake. It chronicles his life, along with the Principia mission and the down-to-the-last-bolt descriptions of life aboard the ISS, by way of the hurdles placed by the British government and the rigors of training at Russia’s Star City military base. In addition, this book discusses the learning curves required in astronaut and mission training and the complexity of the technologies required to launch an astronaut and keep them alive for months on end. This book underscores the fact that technology and training, unlike space, do not exist in a vacuum; complex technical systems, like the ISS, interact with the variables of human personality, and the cultural background of the astronauts. .

  12. Capacity Bounds and High-SNR Capacity of MIMO Intensity-Modulation Optical Channels

    KAUST Repository

    Chaaban, Anas

    2017-06-01

    The capacity of the intensity modulation direct detection multiple-input multiple-output channel is studied. Therein, the nonnegativity constraint of the transmit signal limits the applicability of classical schemes, including precoding. Thus, new ways are required for deriving capacity lower and upper bounds for this channel. To this end, capacity lower bounds are developed by deriving the achievable rates of two precoding-free schemes: Channel inversion and QR decomposition. The achievable rate of a DC-offset SVD-based scheme is also derived as a benchmark. Then, capacity upper bounds are derived and compared against the lower bounds. As a result, the capacity at high signal-to-noise ratio (SNR) is characterized for the case where the number of transmit apertures is not larger than the number of receive apertures, and is shown to be achievable by the QR decomposition scheme. This is shown for a channel with average intensity or peak intensity constraints. For a channel with both constraints, the high-SNR capacity is approximated within a small gap. Extensions to a channel with more transmit apertures than receive apertures are discussed, and capacity bounds for this case are derived.

  13. Pharmacokinetics of mitomycin C in dogs: application of a high-performance liquid chromatographic assay.

    Science.gov (United States)

    Barbhaiya, R H; Papp, E A; Van Harken, D R; Smyth, R D

    1984-09-01

    A normal-phase high-performance liquid chromatographic (HPLC) assay was developed for the determination of mitomycin C in plasma and urine. The method involves extraction of mitomycin C from plasma or urine into ethyl acetate-2-propanol-chloroform (70:15:15) with UV detection at 365 nm. Quantitation was performed with an internal standard (porfiromycin) by the peak height ratio method. Excellent correlation was obtained between the HPLC assay and the established microbiological cup-plate bioassay. The pharmacokinetics of mitomycin C were investigated in beagle dogs following a 1-mg/kg iv (22-mg/m2) bolus dose. The plasma mitomycin C concentration versus time data were analyzed by using an open three-compartment model. The average volume of distribution was 1.90 L or 17% of body weight for the central compartment and 7.7 L or 68% of body weight for the terminal elimination phase. The volumes of distribution at steady state, calculated by model-dependent and -independent methods, compared very well with each other and were 6.5 L or 58% of body weight. Total body clearance averaged 112 mL/min, and the mean terminal plasma half-life was 53 min. The 0-24-h urinary excretion of intact mitomycin C accounted for 19% of the dose. The terminal half-life and percent urinary recovery of mitomycin C in dogs is similar to that in humans. Based on these observations, the dog appears to be a good model for studying the disposition of mitomycin C.

  14. Chromatographic fingerprint analysis and simultaneous determination of eight lignans in Justicia procumbens and its compound preparation by HPLC-DAD.

    Science.gov (United States)

    Wang, Linan; Pan, Jianyu; Yang, Meihua; Wu, Jun; Yang, Junshan

    2011-03-01

    HPLC fingerprints were developed for the quality evaluation of Justicia procumbens and its compound preparation, Jian-er syrup, together with the simultaneous quantification of eight arylnaphthalide lignans (6'-hydroxy justicidin B, 6'-hydroxy justicidin A, 6'-hydroxy justicidin C, justicidin B, chinensinaphthol methyl ether, justicidin C, taiwanin C, and neojusticin A). Samples were separated with a Shiseido Capcell Pak C(18) reversed-phase column (250×4.6 mm id, 5 μm) using acetonitrile and water as the mobile phase. The column temperature was maintained at 35°C and the wavelength of detector was set at 256 nm. For fingerprint analysis, 17 peaks were selected as the characteristic peaks for the evaluation of the similarities among different J. procumbens samples collected in different places. The structures of lignans were confirmed by diagnostic fragments in the positive ESI-MS(n) . The new method was successfully applied for the chromatographic fingerprint analysis and simultaneous determination of eight lignans in its compound preparation, Jian-er syrup. All the results indicated that HPLC fingerprint assay in combination with multi-marker determination afforded a useful method for the quality control of J. procumbens and its compound preparation, Jian-er syrup.

  15. Post-synthetic modification of MIL-101(Cr) with pyridine for high-performance liquid chromatographic separation of tocopherols.

    Science.gov (United States)

    Yang, Fang; Yang, Cheng-Xiong; Yan, Xiu-Ping

    2015-05-01

    Effective separation of tocopherols is challenging and significant due to their structural similarity and important biological role. Here we report the post-synthetic modification of metal-organic framework (MOF) MIL-101(Cr) with pyridine for high-performance liquid chromatographic (HPLC) separation of tocopherols. Baseline separation of four tocopherols was achieved on a pyridine-grafted MIL-101(Cr) packed column within 10 min using hexane/isopropanol (96:4, v/v) as the mobile phase at a flow rate of 0.5 mL min(-1). The pyridine-grafted MIL-101(Cr) packed column gave high column efficiency (85,000 plates m(-1) for δ-tocopherol) and good precision (0.2-0.3% for retention time, 1.8-3.4% for peak area, 2.6-2.7% for peak height), and also offered much better performance than unmodified MIL-101(Cr) and commercial amino-bonded silica packed column for HPLC separation of tocopherols. The results not only show the promising application of pyridine-grafted MIL-101(Cr) as a novel stationary phase for HPLC separation of tocopherols, but also reveal a facile post-modification of MOFs to expand the application of MOFs in separation sciences.

  16. Liquid chromatographic determination of beta-naphthoxyacetic acid in tomatoes.

    Science.gov (United States)

    Gökmen, V; Acar, J

    1998-03-06

    An alternative high-performance liquid chromatographic method for the determination of beta-naphthoxyacetic acid (BNOA) in tomatoes is described. BNOA was extracted from tomatoes with acetone-dichloromethane (2:1). The extract was cleaned up by Bio-Beads S-X3 gel-permeation chromatography and by partitioning. A reversed-phase C18 column was used for HPLC analysis. The mobile phase was acetonitrile-2% acetic acid in water (50:50, v/v) pumped at a flow-rate of 1.0 ml/min. Retention time of BNOA was ca. 7 min with a percentage coefficient of variation of 0.71. Resolution of BNOA was good on the column. Percentage recoveries of BNOA were 79.5 +/- 6.82, 94.8 +/- 2.70 and 86.4 +/- 16.43 for the corresponding spiking levels of 0.5, 1.0 and 2.0 micrograms per g tomato, respectively. Analysis of 10 greenhouse tomato samples from local markets in Ankara showed no BNOA residue.

  17. Gas chromatographic validated method for quantification of ayurvedic polyherbal formulation

    Directory of Open Access Journals (Sweden)

    Navdeep Saini

    2015-01-01

    Full Text Available A new gas chromatographic-flame ionization detector (GC-FID method was developed for quantification of ayurvedic polyherbal formulation. The GC-FID method was found highly accurate, sensitive, simple and precise. This method was validated as per international conference on harmonization (ICH guidelines. Experimental work was performed by nonpolar capillary column (Zb-5, 5%-Phenyl-95%-dimethylpolysiloxane. Film thickness of capillary column (Zb-5 was (0.25 μm and length 30 m × 0.25 mm i.d. The temperature of the oven, injector and detector were 200, 210 and 280°C respectively. Data processing system was applied to obtain data. The standards and test samples were prepared in absolute ethanol. The principle constituents t-Anethol, d-Limonene, cuminaldehyde and thymol were found in ayurvedic polyherbal formulation. The ICH validation parameters for the proposed procedure, recovery (limit 98.85-100.76%, precision (<1.00%, limits of detection, limits of quantification and linearity (r2 = 0.995 ± 0.002 were observed under acceptance limit. Validation results were statistically calculated. The result shows that method is selective and reproducible for quantification of ayurvedic polyherbal formulation. The presented GC method can be applied for the routine analysis of principle constituents as well as ayurvedic polyherbal formulation.

  18. Chromatographic Studies of Protein-Based Chiral Separations

    Science.gov (United States)

    Bi, Cong; Zheng, Xiwei; Azaria, Shiden; Beeram, Sandya; Li, Zhao; Hage, David S.

    2016-01-01

    The development of separation methods for the analysis and resolution of chiral drugs and solutes has been an area of ongoing interest in pharmaceutical research. The use of proteins as chiral binding agents in high-performance liquid chromatography (HPLC) has been an approach that has received particular attention in such work. This report provides an overview of proteins that have been used as binding agents to create chiral stationary phases (CSPs) and in the use of chromatographic methods to study these materials and protein-based chiral separations. The supports and methods that have been employed to prepare protein-based CSPs will also be discussed and compared. Specific types of CSPs that are considered include those that employ serum transport proteins (e.g., human serum albumin, bovine serum albumin, and alpha1-acid glycoprotein), enzymes (e.g., penicillin G acylase, cellobiohydrolases, and α-chymotrypsin) or other types of proteins (e.g., ovomucoid, antibodies, and avidin or streptavidin). The properties and applications for each type of protein and CSP will also be discussed in terms of their use in chromatography and chiral separations.

  19. Authenticity analysis of pear juice employing chromatographic fingerprinting.

    Science.gov (United States)

    Willems, Jamie L; Low, Nicholas H

    2014-12-01

    Pear juice is predominately composed of carbohydrates/polyols (>95% of the total soluble solids), making it susceptible to adulteration by the addition of less expensive commercial sweeteners. In this research, the major carbohydrate and polyol (fructose, glucose, sucrose, and sorbitol) content of 32 pure pear juices representing five world producing regions and three years of production was determined. Additionally, methods employing oligosaccharide profiling to detect the debasing of these samples with four commercial sweeteners (HFCS 55 and 90, TIS, and HIS) were developed using capillary gas chromatography with flame ionization detection (CGC-FID) and high-performance liquid chromatography with pulsed amperometric detection (HPAE-PAD). Detection limits for the four commercial sweeteners ranged from 0.5 to 5.0% (v/v). In addition, the developed CGC-FID method could be used to (a) detect the addition of pear to apple juice via arbutin detection and (b) determine if a pear juice was produced using enzymatic liquefaction via the presence of O-β-d-glucopyranosyl-(1→4)-d-glucopyranose (cellobiose), all within a single chromatographic analysis.

  20. Comprehensive two-dimensional liquid chromatographic analysis of poloxamers.

    Science.gov (United States)

    Malik, Muhammad Imran; Lee, Sanghoon; Chang, Taihyun

    2016-04-15

    Poloxamers are low molar mass triblock copolymers of poly(ethylene oxide) (PEO) and poly(propylene oxide) (PPO), having number of applications as non-ionic surfactants. Comprehensive one and two-dimensional liquid chromatographic (LC) analysis of these materials is proposed in this study. The separation of oligomers of both types (PEO and PPO) is demonstrated for several commercial poloxamers. This is accomplished at the critical conditions for one of the block while interaction for the other block. Reversed phase LC at CAP of PEO allowed for oligomeric separation of triblock copolymers with regard to PPO block whereas normal phase LC at CAP of PPO renders oligomeric separation with respect to PEO block. The oligomeric separation with regard to PEO and PPO are coupled online (comprehensive 2D-LC) to reveal two-dimensional contour plots by unconventional 2D IC×IC (interaction chromatography) coupling. The study provides chemical composition mapping of both PEO and PPO, equivalent to combined molar mass and chemical composition mapping for several commercial poloxamers.

  1. Liquid chromatographic analysis of oxytocin and its related substances.

    Science.gov (United States)

    Ashenafi, Dunge; Van Hemelrijck, Elise; Chopra, Shruti; Hoogmartens, Jos; Adams, Erwin

    2010-01-05

    A selective gradient liquid chromatographic (LC) method for the determination of oxytocin (OT) and its related substances in bulk drugs has been developed. The method uses a reversed-phase C18 column (25 cm x 4.0 mm i.d.), 5 microm kept at 40 degrees C. The mobile phases consist of acetonitrile, dihydrogen phosphate solution pH 4.4 and water. The flow rate is 1.0 ml/min. UV detection is performed at 220 nm. A system suitability test (SST) was developed to govern the quality of the separation. The separation towards OT components was investigated on different C18 columns. The developed method was further validated with respect to robustness, precision, sensitivity and linearity. A central composite design was applied to examine the robustness of the method. The method shows good precision, sensitivity, linearity and robustness. Two commercial OT samples were examined using this method. Furthermore, the method proved to be successful when applied to analyze a marketed OT formulation for injection.

  2. Chromatographic separation of low-temperature tar. Part III

    Energy Technology Data Exchange (ETDEWEB)

    Terres, E.; Gebert, F.; Huelsemann, H.; Petereit, H.; Toepsch, H.; Ruppert, W.

    1955-01-01

    Experiments with crude phenolic mixtures in benzene-MeOH over an alumina chromatographic column are reported. The most effective separation into crude fractions was obtained from a petroleum-ether solution with benzene and benzene-MeOH elution. These fractions are analyzed by paper chromatography. R/sub f/ values for 29 phenols and benzoic acid from water-saturated AmOH are given. Folin-Denis reagent and ultraviolet absorption is used for identification of the phenolic compounds. R/sub f/ values for monohydroxy compounds are larger than 0.9, dihydroxy 0.80 to 0.9, trihydroxy 0.6, hydroxytoluic acids 0.39 to 0.56. R/sub f/ values of Na and K salts are different from those of the free phenols. Tests in aqueous solution near 0/sup 0/ gave important results. R/sub f/ values of the less polar materials decrease and less material is lost through evaporation, smaller and sharper spots are obtained and liquids move at a more even rate. A series of isomeric alkyl phenols is reported; ortho alkyl groups decrease the migration rate most effectively.

  3. Peak, multi-peak and broadband absorption in graphene-based one-dimensional photonic crystal

    Science.gov (United States)

    Miloua, R.; Kebbab, Z.; Chiker, F.; Khadraoui, M.; Sahraoui, K.; Bouzidi, A.; Medles, M.; Mathieu, C.; Benramdane, N.

    2014-11-01

    We theoretically investigate the possibility of enhancing light absorption in graphene-based one dimensional photonic crystal. We demonstrate that it is possible to achieve total light absorption at technologically important wavelengths using one-dimensional graphene-based photonic crystals. By means of the transfer matrix method, we investigate the effect of refractive indices and layer numbers on the optical response of the structure. We found that it is possible to achieve one peak, multi-peak or broadband, and complete optical absorption. As a result, the proposed photonic structures enable myriad potential applications such as photodetection, shielding and optical sensing.

  4. Reductions in labour capacity from heat stress under climate warming

    Science.gov (United States)

    Dunne, John P.; Stouffer, Ronald J.; John, Jasmin G.

    2013-06-01

    A fundamental aspect of greenhouse-gas-induced warming is a global-scale increase in absolute humidity. Under continued warming, this response has been shown to pose increasingly severe limitations on human activity in tropical and mid-latitudes during peak months of heat stress. One heat-stress metric with broad occupational health applications is wet-bulb globe temperature. We combine wet-bulb globe temperatures from global climate historical reanalysis and Earth System Model (ESM2M) projections with industrial and military guidelines for an acclimated individual's occupational capacity to safely perform sustained labour under environmental heat stress (labour capacity)--here defined as a global population-weighted metric temporally fixed at the 2010 distribution. We estimate that environmental heat stress has reduced labour capacity to 90% in peak months over the past few decades. ESM2M projects labour capacity reduction to 80% in peak months by 2050. Under the highest scenario considered (Representative Concentration Pathway 8.5), ESM2M projects labour capacity reduction to less than 40% by 2200 in peak months, with most tropical and mid-latitudes experiencing extreme climatological heat stress. Uncertainties and caveats associated with these projections include climate sensitivity, climate warming patterns, CO2 emissions, future population distributions, and technological and societal change.

  5. Geothermal Plant Capacity Factors

    Energy Technology Data Exchange (ETDEWEB)

    Greg Mines; Jay Nathwani; Christopher Richard; Hillary Hanson; Rachel Wood

    2015-01-01

    The capacity factors recently provided by the Energy Information Administration (EIA) indicated this plant performance metric had declined for geothermal power plants since 2008. Though capacity factor is a term commonly used by geothermal stakeholders to express the ability of a plant to produce power, it is a term frequently misunderstood and in some instances incorrectly used. In this paper we discuss how this capacity factor is defined and utilized by the EIA, including discussion on the information that the EIA requests from operations in their 923 and 860 forms that are submitted both monthly and annually by geothermal operators. A discussion is also provided regarding the entities utilizing the information in the EIA reports, and how those entities can misinterpret the data being supplied by the operators. The intent of the paper is to inform the facility operators as the importance of the accuracy of the data that they provide, and the implications of not providing the correct information.

  6. Dual capacity reciprocating compressor

    Science.gov (United States)

    Wolfe, Robert W.

    1984-01-01

    A multi-cylinder compressor 10 particularly useful in connection with northern climate heat pumps and in which different capacities are available in accordance with reversing motor 16 rotation is provided with an eccentric cam 38 on a crank pin 34 under a fraction of the connecting rods, and arranged for rotation upon the crank pin between opposite positions 180.degree. apart so that with cam rotation on the crank pin such that the crank throw is at its normal maximum value all pistons pump at full capacity, and with rotation of the crank shaft in the opposite direction the cam moves to a circumferential position on the crank pin such that the overall crank throw is zero. Pistons 24 whose connecting rods 30 ride on a crank pin 36 without a cam pump their normal rate with either crank rotational direction. Thus a small clearance volume is provided for any piston that moves when in either capacity mode of operation.

  7. Capacity Maximizing Constellations

    Science.gov (United States)

    Barsoum, Maged; Jones, Christopher

    2010-01-01

    Some non-traditional signal constellations have been proposed for transmission of data over the Additive White Gaussian Noise (AWGN) channel using such channel-capacity-approaching codes as low-density parity-check (LDPC) or turbo codes. Computational simulations have shown performance gains of more than 1 dB over traditional constellations. These gains could be translated to bandwidth- efficient communications, variously, over longer distances, using less power, or using smaller antennas. The proposed constellations have been used in a bit-interleaved coded modulation system employing state-ofthe-art LDPC codes. In computational simulations, these constellations were shown to afford performance gains over traditional constellations as predicted by the gap between the parallel decoding capacity of the constellations and the Gaussian capacity

  8. Weather and road capacity

    DEFF Research Database (Denmark)

    Jensen, Thomas Christian

    2014-01-01

    The paper presents estimations of the effect of bad weather on the observed speed on a Danish highway section; Køge Bugt Motorvejen. The paper concludes that weather, primarily precipitation and snow, has a clear negative effect on speed when the road is not in hypercongestion mode. Furthermore......, the capacity of the highway seems to be reduced in bad weather and there are indications that travel time variability is also increased, at least in free-flow conditions. Heavy precipitation reduces speed and capacity by around 5-8%, whereas snow primarily reduces capacity. Other weather variables......-parametrically against traffic density and in step 2 the residuals from step 1 are regressed linearly against the weather variables. The choice of a non-parametric method is made to avoid constricting ties from a parametric specification and because the focus here is not on the relationship between traffic flow...

  9. Impacts of rising air temperatures on electric transmission ampacity and peak electricity load in the United States

    Science.gov (United States)

    Bartos, Matthew; Chester, Mikhail; Johnson, Nathan; Gorman, Brandon; Eisenberg, Daniel; Linkov, Igor; Bates, Matthew

    2016-11-01

    Climate change may constrain future electricity supply adequacy by reducing electric transmission capacity and increasing electricity demand. The carrying capacity of electric power cables decreases as ambient air temperatures rise; similarly, during the summer peak period, electricity loads typically increase with hotter air temperatures due to increased air conditioning usage. As atmospheric carbon concentrations increase, higher ambient air temperatures may strain power infrastructure by simultaneously reducing transmission capacity and increasing peak electricity load. We estimate the impacts of rising ambient air temperatures on electric transmission ampacity and peak per-capita electricity load for 121 planning areas in the United States using downscaled global climate model projections. Together, these planning areas account for roughly 80% of current peak summertime load. We estimate climate-attributable capacity reductions to transmission lines by constructing thermal models of representative conductors, then forcing these models with future temperature projections to determine the percent change in rated ampacity. Next, we assess the impact of climate change on electricity load by using historical relationships between ambient temperature and utility-scale summertime peak load to estimate the extent to which climate change will incur additional peak load increases. We find that by mid-century (2040-2060), increases in ambient air temperature may reduce average summertime transmission capacity by 1.9%-5.8% relative to the 1990-2010 reference period. At the same time, peak per-capita summertime loads may rise by 4.2%-15% on average due to increases in ambient air temperature. In the absence of energy efficiency gains, demand-side management programs and transmission infrastructure upgrades, these load increases have the potential to upset current assumptions about future electricity supply adequacy.

  10. Piper nigrum: micropropagation, antioxidative enzyme activities, and chromatographic fingerprint analysis for quality control.

    Science.gov (United States)

    Ahmad, Nisar; Abbasi, Bilal Haider; Rahman, Inayat ur; Fazal, Hina

    2013-04-01

    A reliable in vitro regeneration system for the economical and medicinally important Piper nigrum L. has been established. Callus and shoot regeneration was encouraged from leaf portions on Murashige and Skoog (MS) medium augmented with varied concentrations of plant growth regulators. A higher callus production (90 %) was observed in explants incubated on MS medium incorporated with 1.0 mg L(-1) 6-benzyladenine (BA) along with 0.5 mg L(-1) gibberellic acid after 4 weeks of culture. Moreover, a callogenic response of 85 % was also recorded for 1.0 mg L(-1) BA in combination with 0.25 mg L(-1) α-naphthalene acetic acid (NAA) and 0.25 mg L(-1) 2,4-dichlorophenoxyacetic acid or 0.5 mg L(-1) indole butyric acid (IBA) along with 0.25 mg L(-1) NAA and indole acetic acid. Subsequent sub-culturing of callus after 4 weeks of culture onto MS medium supplemented with 1.5 mg L(-1) thiodiazoran or 1.5 mg L(-1) IBA induced 100 % shoot response. Rooted plantlets were achieved on medium containing varied concentrations of auxins. The antioxidative enzyme activities [superoxide dismutase (SOD), peroxidase (POD), catalase (CAT), and ascorbate peroxidase (APX)] revealed that significantly higher SOD was observed in regenerated plantlets than in other tissues. However, POD, CAT, and APX were higher in callus than in other tissues. A high-performance liquid chromatography (HPLC) fingerprint analysis protocol was established for quality control in different in vitro-regenerated tissues of P. nigrum L. During analysis, most of the common peaks represent the active principle "piperine." The chemical contents, especially piperine, showed variation from callus culture to whole plantlet regeneration. Based on the deviation in chromatographic peaks, the in vitro-regenerated plantlets exhibit a nearly similar piperine profile to acclimated plantlets. The in vitro regeneration system and HPLC fingerprint analysis established here brought a novel approach to the quality control of in vitro

  11. Comments on metal oxide surge arresters surges energy absorption capacity

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, M.L.B. [Escola Federal de Engenharia de Itajuba, Minas Gerais (Brazil); Zanetta, L.C. Jr. [E. Politecnica Univ. de Sao Paulo, Sao Paulo (Brazil)

    1996-12-31

    This paper presents an approach to determine the energy absorption capacity of metal oxide surge arrester resistors. The proposed approach deals with the discharge current peak versus discharge current time relation. A testing method and a statistical evaluation are proposed. After determining the discharge current withstanding limit of the tested metal oxide resistors, the prospective energy absorption capacity limit is computed. Finally, comments on the obtained results are presented.

  12. Norwegian hydropower a valuable peak power source

    Energy Technology Data Exchange (ETDEWEB)

    Brekke, Hermod

    2010-07-01

    given on a possible increase of the Norwegian hydropower peak power production to meet the growing the European demand for peak power caused by the growing non stationary production from wind mills and ocean energy from waves and sea current. Also building of reversible pump turbine power plants will be discussed even if approximately 10% power will be consumed by loss in the pumping phase compared to direct use of the water from reservoirs. (Author)

  13. Gas chromatographic analysis of simmondsins and simmondsin ferulates in jojoba meal.

    Science.gov (United States)

    Van Boven, M; Holser, R; Cokelaere, M; Flo, G; Decuypere, E

    2000-09-01

    A capillary gas chromatographic method was developed for the simultaneous determination of simmondsins and simmondsin ferulates in jojoba meal, in detoxified jojoba meal, in jojoba meal extracts, and in animal food mixtures.

  14. Development and Validation of a Chromatographic Method for the Analysis of Multicompound Pharmaceutical Preparations

    OpenAIRE

    Ferreyra, Carola; Ortiz, Cristina; Bertorello, M. M. De

    2000-01-01

    A reverse phase high performance liquid chromatographic assay was carried out for the simultaneous determination of two out of three active principles present in a pharmaceutical preparation. This method was developed to assess the quality of the product.

  15. Bismuth(V) oxide and silver bismuthate as oxidizing agents for gas-chromatographic elemental microanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Shvykin, A.Y.; Platonov, V.V.; Proskuryakov, V.P.; Chilachava, K.B.; Khmarin, E.M.; Kovtun, I.V. [Tolstoy State Pedag University, Tula (Russian Federation)

    2004-07-01

    Bismuth(V) oxide, silver bismuthate, and a mixture of bismuth(V) oxide with fine silver powder were studied as oxidizing additives in gas-chromatographic elemental microanalysis of readily combustible organic substances and coal.

  16. Comparative tests to improve the gas chromatographic analysis of chlorobornanes in fish samples

    NARCIS (Netherlands)

    Boer, de J.; Leonards, P.E.G.; Klungsoyr, J.; McHugh, B.; Nixon, E.; McGovern, E.; Rimkus, G.G.

    2003-01-01

    A comparison was made between electron capture negative ionization quadrupole mass spectrometry (ECNI-MS) and electron capture detection (ECD) with regard to repeatability and reproducibility for the gas chromatographic (GC) analysis of toxaphene congeners [chlorobornanes (CHBs)]. The tests,

  17. 21 CFR 862.2230 - Chromatographic separation material for clinical use.

    Science.gov (United States)

    2010-04-01

    ... chromatographic separation material for clinical use is a device accessory (e.g., ion exchange absorbents, ion exchagne resins, and ion papers) intended for use in ion exchange chromatography, a procedure in which...

  18. Miniaturized MEMS-Based Gas Chromatograph for High Inertial Loads Associated with Planetary Missions Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Thorleaf Research, Inc. proposes to develop a rugged, miniaturized, low power MEMS-based gas chromatograph (GC) capable of handling the high inertial loads...

  19. Derivatization reactions in the gas—liquid chromatographic analysis of drugs in biological fluids

    NARCIS (Netherlands)

    Hulshoff, A.; Lingeman, H.

    1984-01-01

    Alkylation, acylation, silylation and other derivatization reactions applied to the gas chromatographic analysis of drugs in biological matrices are reviewed. Reaction conditions are discussed in relation to reaction mechanisms. Detector-oriented labelling of drugs, and derivatization with chiral re

  20. Peak-valley-peak pattern of histone modifications delineates active regulatory elements and their directionality

    DEFF Research Database (Denmark)

    Pundhir, Sachin; Bagger, Frederik Otzen; Lauridsen, Felicia Kathrine Bratt

    2016-01-01

    Formation of nucleosome free region (NFR) accompanied by specific histone modifications at flanking nucleosomes is an important prerequisite for enhancer and promoter activity. Due to this process, active regulatory elements often exhibit a distinct shape of histone signal in the form of a peak...

  1. Peak phosphorus - peak food? The need to close the phosphorus cycle.

    Science.gov (United States)

    Rhodes, Christopher J

    2013-01-01

    The peak in the world production of phosphorus has been predicted to occur in 2033, based on world reserves of rock phosphate (URR) reckoned at around 24,000 million tonnes (Mt), with around 18,000 Mt remaining. This figure was reckoned-up to 71,000 Mt, by the USGS, in 2012, but a production maximum during the present century is still highly probable. There are complex issues over what the demand will be for phosphorus in the future, as measured against a rising population (from 7 billion to over 9 billion in 2050), and a greater per capita demand for fertiliser to grow more grain, in part to feed animals and meet a rising demand for meat by a human species that is not merely more populous but more affluent. As a counterweight to this, we may expect that greater efficiencies in the use of phosphorus - including recycling from farms and of human and animal waste - will reduce the per capita demand for phosphate rock. The unseen game changer is peak oil, since phosphate is mined and recovered using machinery powered by liquid fuels refined from crude oil. Hence, peak oil and peak phosphorus might appear as conjoined twins. There is no unequivocal case that we can afford to ignore the likelihood of a supply-demand gap for phosphorus occurring sometime this century, and it would be perilous to do so.

  2. Torque/velocity properties of human knee muscles: peak and angle-specific estimates.

    Science.gov (United States)

    Caldwell, G E; Adams, W B; Whetstone, M R

    1993-09-01

    Angle-specific (AS) torque/velocity data have been used to avoid angle related variation in peak torque capacity. However, series elastic structures cause the contractile velocity of active force-producing tissue to differ from external joint velocity except at peak torque. Alternatively, angle related variation may be removed by normalizing peak torque to the isometric maximum at that angular position. The AS, peak (P), and normalized peak (NP) methods were compared in isovelocity knee flexion and extension at velocities between 50 and 250 degrees s-1 for 8 male subjects. The P and NP methods gave more similar torque/velocity relations than the AS method. Further, very little variation in peak torque was attributed to differences in joint angle. Both the P and AS methods illustrate that relative quadriceps/hamstrings torque capability (flexor/extensor ratio) increases slightly with velocity. It is proposed that antagonist muscle torque capabilities should be compared at different angular positions to assess muscular imbalance.

  3. Analysis of the Peak Resistance Frequency Method.

    Science.gov (United States)

    Wang, Boshuo; Weiland, James D

    2016-10-01

    This study analyzes the peak resistance frequency (PRF) method described by Mercanzini et al., a method that can easily extract the tissue resistance from impedance spectroscopy for many neural engineering applications but has no analytical description thus far. Mathematical analyses and computer simulations were used to explore underlying principles, accuracy, and limitations of the PRF method. The mathematical analyses demonstrated that the PRF method has an inherent but correctable deviation dependent on the idealness of the electrode-tissue interface, which is validated by simulations. Further simulations show that both frequency sampling and noise affect the accuracy of the PRF method, and in general, it performs less accurately than least squares methods. However, the PRF method achieves simplicity and reduced measurement and computation time at the expense of accuracy. From the qualitative results, the PRF method can work with reasonable precision and simplicity, although its limitation and the idealness of the electrode-tissue interface involved should be taken into consideration. This paper provides a mathematical foundation for the PRF method and its practical implementation.

  4. Z-peaked excess in goldstini scenarios

    CERN Document Server

    Liew, Seng Pei; Mawatari, Kentarou; Sakurai, Kazuki; Vereecken, Matthias

    2015-01-01

    We study a possible explanation of a 3.0 $\\sigma$ excess recently reported by the ATLAS Collaboration in events with Z-peaked same-flavour opposite-sign lepton pair, jets and large missing transverse momentum in the context of gauge-mediated SUSY breaking with more than one hidden sector, the so-called goldstini scenario. In a certain parameter space, the gluino two-body decay chain $\\tilde g\\to g\\tilde\\chi^0_{1,2}\\to gZ\\tilde G'$ becomes dominant, where $\\tilde\\chi^0_{1,2}$ and $\\tilde G'$ are the Higgsino-like neutralino and the massive pseudo-goldstino, respectively, and gluino pair production can contribute to the signal. We find that a mass spectrum such as $m_{\\tilde g}\\sim 900$ GeV, $m_{\\tilde\\chi^0_{1,2}}\\sim 700$ GeV and $m_{\\tilde G'}\\sim 600$ GeV demonstrates the rate and the distributions of the excess, without conflicting with the stringent constraints from jets plus missing energy analyses and with the CMS constraint on the identical final state.

  5. Z-peaked excess in goldstini scenarios

    Directory of Open Access Journals (Sweden)

    Seng Pei Liew

    2015-11-01

    Full Text Available We study a possible explanation of a 3.0 σ excess recently reported by the ATLAS Collaboration in events with Z-peaked same-flavour opposite-sign lepton pair, jets and large missing transverse momentum in the context of gauge-mediated SUSY breaking with more than one hidden sector, the so-called goldstini scenario. In a certain parameter space, the gluino two-body decay chain g˜→gχ˜1,20→gZG˜′ becomes dominant, where χ˜1,20 and G˜′ are the Higgsino-like neutralino and the massive pseudo-goldstino, respectively, and gluino pair production can contribute to the signal. We find that a mass spectrum such as mg˜∼1000 GeV, mχ˜1,20∼800 GeV and mG˜′∼600 GeV demonstrates the rate and the distributions of the excess, without conflicting with the stringent constraints from jets plus missing energy analyses and with the CMS constraint on the identical final state.

  6. Asymmetry parameter of peaked Fano line shapes

    Science.gov (United States)

    Meierott, S.; Hotz, T.; Néel, N.; Kröger, J.

    2016-10-01

    The spectroscopic line shape of electronic and vibrational excitations is ubiquitously described by a Fano profile. In the case of nearly symmetric and peaked Fano line shapes, the fit of the conventional Fano function to experimental data leads to difficulties in unambiguously extracting the asymmetry parameter, which may vary over orders of magnitude without degrading the quality of the fit. Moreover, the extracted asymmetry parameter depends on initially guessed values. Using the spectroscopic signature of the single-Co Kondo effect on Au(110) the ambiguity of the extracted asymmetry parameter is traced to the highly symmetric resonance profile combined with the inevitable scattering of experimental data. An improved parameterization of the conventional Fano function is suggested that enables the nonlinear optimization in a reduced parameter space. In addition, the presence of a global minimum in the sum of squared residuals and thus the independence of start parameters may conveniently be identified in a two-dimensional plot. An angular representation of the asymmetry parameter is suggested in order to reliably determine uncertainty margins via linear error propagation.

  7. Preparative chromatographic resolution of racemates using HPLC and SFC in a pharmaceutical discovery environment.

    Science.gov (United States)

    Miller, Larry; Potter, Matt

    2008-11-01

    The preparative chromatographic resolution of racemates has become a standard approach for the generation of enantiomers in pharmaceutical discovery laboratories. This paper will discuss the use of preparative HPLC and SFC to generate individual enantiomers for discovery activities. Analytical HPLC and SFC method development to rapidly screen chiral stationary phases and solvent combinations will be presented. The usefulness of preparative chromatographic resolution of racemates will be demonstrated through the presentation of numerous non-routine case studies from the laboratories at Amgen.

  8. Hydrocarbon Fuel Thermal Performance Modeling based on Systematic Measurement and Comprehensive Chromatographic Analysis

    Science.gov (United States)

    2016-07-31

    distribution unlimited Hydrocarbon Fuel Thermal Performance Modeling based on Systematic Measurement and Comprehensive Chromatographic Analysis Matthew...Technical Note 3. DATES COVERED (From - To) 04 January 2016 - 31 July 2016 4. TITLE AND SUBTITLE Hydrocarbon Fuel Thermal Performance Modeling based on...Systematic Measurement and Comprehensive Chromatographic Analysis 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S

  9. Development, modelling, optimisation and scale-up of chromatographic purification of a therapeutic protein

    DEFF Research Database (Denmark)

    Mollerup, Jørgen; Hansen, Thomas Budde; Kidal, Steffen

    2007-01-01

    Development of a chromatographic purification step proceeds through a number of stages. High-throughput screening techniques are used to identify suitable resins. This technique is also suitable for the design of a capture step and some intermediate chromatographic steps, but development and true...... by industry. The theory of residence time based scale-up is developed and applied. (c) 2007 Elsevier B.V. All rights reserved....

  10. Bead Injection Extraction Chromatography using High-capacity Lab-on-Valve as a Front End to Inductively Coupled Plasma Mass Spectrometry for Rapid Urine Radiobioassay

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2013-01-01

    A novel bead injection (BI) extraction chromatographic microflow system exploiting high-capacity lab-on-valve (LOV) platform coupled with inductively coupled plasma mass spectrometric detection is developed for rapid and automated determination of plutonium in human urine. A microconduit (1 mL) i...

  11. Fast-slow climate dynamics and peak global warming

    Science.gov (United States)

    Seshadri, Ashwin K.

    2016-06-01

    The dynamics of a linear two-box energy balance climate model is analyzed as a fast-slow system, where the atmosphere, land, and near-surface ocean taken together respond within few years to external forcing whereas the deep-ocean responds much more slowly. Solutions to this system are approximated by estimating the system's time-constants using a first-order expansion of the system's eigenvalue problem in a perturbation parameter, which is the ratio of heat capacities of upper and lower boxes. The solution naturally admits an interpretation in terms of a fast response that depends approximately on radiative forcing and a slow response depending on integrals of radiative forcing with respect to time. The slow response is inversely proportional to the "damping-timescale", the timescale with which deep-ocean warming influences global warming. Applications of approximate solutions are discussed: conditions for a warming peak, effects of an individual pulse emission of carbon dioxide (CO2 ), and metrics for estimating and comparing contributions of different climate forcers to maximum global warming.

  12. Relation between cardiac dimensions and peak oxygen uptake

    Directory of Open Access Journals (Sweden)

    Mosén H

    2010-02-01

    Full Text Available Abstract Background Long term endurance training is known to increase peak oxygen uptake ( and induce morphological changes of the heart such as increased left ventricular mass (LVM. However, the relationship between and the total heart volume (THV, considering both the left and right ventricular dimensions in both males and females, is not completely described. Therefore, the aim of this study was to test the hypothesis that THV is an independent predictor of and to determine if the left and right ventricles enlarge in the same order of magnitude in males and females with a presumed wide range of THV. Methods and Results The study population consisted of 131 subjects of whom 71 were athletes (30 female and 60 healthy controls (20 female. All subjects underwent cardiovascular MR and maximal incremental exercise test. Total heart volume, LVM and left- and right ventricular end-diastolic volumes (LVEDV, RVEDV were calculated from short-axis images. was significantly correlated to THV, LVM, LVEDV and RVEDV in both males and females. Multivariable analysis showed that THV was a strong, independent predictor of (R2 = 0.74, p 2 = 0.87, p Conclusion Total heart volume is a strong, independent predictor of maximal work capacity for both males and females. Long term endurance training is associated with a physiologically enlarged heart with a balance between the left and right ventricular dimensions in both genders.

  13. Fast-slow climate dynamics and peak global warming

    Science.gov (United States)

    Seshadri, Ashwin K.

    2017-04-01

    The dynamics of a linear two-box energy balance climate model is analyzed as a fast-slow system, where the atmosphere, land, and near-surface ocean taken together respond within few years to external forcing whereas the deep-ocean responds much more slowly. Solutions to this system are approximated by estimating the system's time-constants using a first-order expansion of the system's eigenvalue problem in a perturbation parameter, which is the ratio of heat capacities of upper and lower boxes. The solution naturally admits an interpretation in terms of a fast response that depends approximately on radiative forcing and a slow response depending on integrals of radiative forcing with respect to time. The slow response is inversely proportional to the "damping-timescale", the timescale with which deep-ocean warming influences global warming. Applications of approximate solutions are discussed: conditions for a warming peak, effects of an individual pulse emission of carbon dioxide (CO2), and metrics for estimating and comparing contributions of different climate forcers to maximum global warming.

  14. Testamentary capacity and delirium.

    Science.gov (United States)

    Liptzin, Benjamin; Peisah, Carmelle; Shulman, Kenneth; Finkel, Sanford

    2010-09-01

    With the aging of the population there will be a substantial transfer of wealth in the next 25 years. The presence of delirium can complicate the evaluation of an older person's testamentary capacity and susceptibility to undue influence but has not been well examined in the existing literature. A subcommittee of the IPA Task Force on Testamentary Capacity and Undue Influence undertook to review how to assess prospectively and retrospectively testamentary capacity and susceptibility to undue influence in patients with delirium. The subcommittee identified questions that should be asked in cases where someone changes their will or estate plan towards the end of their life in the presence of delirium. These questions include: was there consistency in the patient's wishes over time? Were these wishes expressed during a "lucid interval" when the person was less confused? Were the patient's wishes clearly expressed in response to open-ended questions? Is there clear documentation of the patient's mental status at the time of the discussion? This review with some case examples provides guidance on how to consider the question of testamentary capacity or susceptibility to undue influence in someone undergoing an episode of delirium.

  15. Flood Bypass Capacity Optimization

    Science.gov (United States)

    Siclari, A.; Hui, R.; Lund, J. R.

    2015-12-01

    Large river flows can damage adjacent flood-prone areas, by exceeding river channel and levee capacities. Particularly large floods are difficult to contain in leveed river banks alone. Flood bypasses often can efficiently reduce flood risks, where excess river flow is diverted over a weir to bypasses, that incur much less damage and cost. Additional benefits of bypasses include ecosystem protection, agriculture, groundwater recharge and recreation. Constructing or expanding an existing bypass costs in land purchase easements, and levee setbacks. Accounting for such benefits and costs, this study develops a simple mathematical model for optimizing flood bypass capacity using benefit-cost and risk analysis. Application to the Yolo Bypass, an existing bypass along the Sacramento River in California, estimates optimal capacity that economically reduces flood damage and increases various benefits, especially for agriculture. Land availability is likely to limit bypass expansion. Compensation for landowners could relax such limitations. Other economic values could affect the optimal results, which are shown by sensitivity analysis on major parameters. By including land geography into the model, location of promising capacity expansions can be identified.

  16. Characterization of low-temperature cofired ceramic tiles as platforms for gas chromatographic separations.

    Science.gov (United States)

    Darko, Ernest; Thurbide, Kevin B; Gerhardt, Geoff C; Michienzi, Joseph

    2013-06-04

    A gas chromatography (GC) column is fabricated within a low-temperature cofired ceramic (LTCC) tile, and its analytical properties are characterized. By using a dual-spiral design, a 100 μm wide square channel up to 15 m in length is produced within an 11 cm × 5.5 cm LTCC tile. The channel is dynamically coated with an OV-101 stationary phase that is cross-linked with dicumyl peroxide. While the uncoated LTCC tiles were able to separate a mixture of n-alkanes, the peak shapes were broad (base width of ~2 min) and tailing. In contrast to this, the coated LTCC tiles produced sharp (base width of ~8-10 s), symmetrical, well-resolved peaks for the same analytes. By using a 7.5 m long channel, about 15,000 plates were obtained for a dodecane test analyte. Further, the coated LTCC tiles were found to produce plate heights that were about 3-fold smaller than those obtained from a conventional capillary GC column of similar length, dimension, and coating operated under the same conditions. As a result, test analyte separations were slightly improved in the LTCC tiles, and their overall performance fared well. In terms of temperature programming, it was found that a series of n-alkanes separated on the LTCC tile provided a cumulative peak capacity of around 54 peaks when using C₈ to C₁₃ as analyte markers. Results indicate that LTCC tiles provide a viable and useful alternative platform for performing good quality GC separations.

  17. Chromatographic profiles of blood plasma free oligosaccharides in patients with cardiovascular disease

    Directory of Open Access Journals (Sweden)

    I. U. Pismenetskaya

    2015-03-01

    Full Text Available Free oligosaccharides (FOS are unbound structural analogs of glycans of glycoconjugates. There are several sources of them inside the cell: 1 multistep pathways of N-glycosylation, 2 the cell quality control and endoplastic reticulum-associated degradation of mis-glycosylated and/or misfolded glycoproteins, 3 lysosomal degradation of mature glycoconjugates. Some of these FOS are the earliest indicators of potential glycosylation alterations that would be revealed in the course of the cell quality control and the endoplastic reticulum-associated degradation. Ischemia and hypertension cause stress of intracellular organelles leading to disruption of their functions. The main objective of the work was the characterization of free oligosaccharides (FOS in plasma obtained from patients with cardiovascular diseases compared to those from healthy subjects to evaluate the potential of these compounds for diagnostics. Chromatographic profiles of FOS composed of 4–12 monosaccharides were obtained and analyzed for quantitative and qualitative differences between the samples. After plasma deproteinization and FOS purification the oligosaccharides were labelled with anthranilic acid (2-AA, separated into the neutral and charged with QAE Sephadex (Q25-120 chromatography and analysed using high-performance liquid chromatography (HPLC. Glucose unit values were determined following comparison with a 2-AA-labelled glucose oligomer ladder derived from a partial hydrolysate of dextran as an external standard. The data were collected and processed using Empower software. The charged FOS were digested with the sialidase from Arthrobacter ureafaciens. 2-AA – labelled free oligosaccharides from transferrin were used as an external standard for the structure decoding. The profiles obtained were compared with intracellular free oligosaccharides of known structures and with the glycan structures and their descriptions in the databases GlycoBase and EUROCarbDB. These

  18. Fundamental studies of chalcogenide nanocrystals, carbonaceous nanoparticles, and chromatographic materials

    Science.gov (United States)

    Baker, Jared Scott

    2011-12-01

    influenced the temporal persistence of the nanocrystals; the pathway through which CdSe NCs degraded depended on the concentration of free, uncoordinated cysteinate. These findings indicate that solution-phase chemistry can determine whether NCs remain intact upon removal from their original reaction mixtures. Departing from the analysis of nanomaterials, an additional chapter focuses on the evaluation of a new chromatographic packing material. Two chromatographic columns packed with superficially porous packing material, Kinetex(TM) 1.7 mum and 2.6 mum C18 particles were evaluated in terms of their physical properties and performance characteristics. These columns were compared to a column packed with a sub-2 mum totally porous material and to a Halo(TM) column packed with 2.7 mum C18 superficially porous packing. The columns packed with superficially porous particles displayed a comparably narrower size distribution, which is narrower than the distribution of the totally porous sub-2 mum particles. Physical characteristics of the Kinetex(TM) particles were evaluated in terms of surface area, pore diameter, and specific pore volume. Total, external, internal and shell porosities among the four different columns were evaluated and compared. The specific permeability for the Kinetex columns showed values close to those predicted by the Kozeny-Carman equation. All four columns were evaluated in terms of their chromatographic performance and compared using the Knox equation. The columns packed with the 2.6 mum and 2.7 mum superficially porous materials showed reduced plate heights below 2, while the sub-2 mum particles showed values of 2.2 and above.

  19. Potential for aging female Aedes aegypti (Diptera: Culicidae) by gas chromatographic analysis of cuticular hydrocarbons, including a field evaluation.

    Science.gov (United States)

    Desena, M L; Clark, J M; Edman, J D; Symington, S B; Scott, T W; Clark, G G; Peters, T M

    1999-11-01

    Gas chromatography with flame-ionization detection was used to measure the time-associated, quantitative changes in the cuticular hydrocarbons of female Aedes aegypti (L.). Cohorts of unstressed Ae. aegypti, Rockefeller strain, were reared and held at 3 constant temperatures (24, 28, and 30 degrees C). Five females from each cohort were taken at 33 degree-day (DD) intervals from 0 to 231 DD (using 17 degrees C as the threshold temperature). Quantitative changes over time of cuticular hydrocarbons associated with gas chromatographic peaks 1 and 5 were identified as having promise for age grading. The relative abundance of peak 1 (pentacosane) decreased linearly from 0 to 132 DD, whereas peak 5 (nonacosane) increased linearly over the same period. Suboptimal larval conditions (crowded and starved), which resulted in physiological stress (decreased size), had negligible effect on the relative abundance of pentacosane and nonacosane. Additionally, the rate of change in the relative abundance of pentacosane and nonacosane were the same for both a recently colonized Chachoengsao (Thailand) strain of Ae. aegypti compared with the long-colonized Rockefeller (Caribbean) strain over a 0-99 DD interval. Two linear regression models, one based on the relative abundance of pentacosane and the other on the logit transformation of these values, were developed for aging female Ae. aegypti. A blind study using laboratory-reared mosquitoes and a mark-release-recapture experiment using field mosquitoes validated these age-grading models and produced promising results for aging females up to 132 DD (19, 12, and 10 calendar days at 24, 28 and 30 degrees C, respectively). Therefore the regression models, based on the relative abundance of these 2 cuticular hydrocarbons, appeared to be a useful approach for age-grading Ae. aegypti up to at least 12 d of age regardless of environmental conditions (temperature and stress) and population history (origin and colonization time).

  20. Particle size analyses of porous silica and hybrid silica chromatographic support particles. Comparison of flow/hyperlayer field-flow fractionation with scanning electron microscopy, electrical sensing zone, and static light scattering.

    Science.gov (United States)

    Xu, Yuehong

    2008-05-16

    Porous silica and hybrid silica chromatographic support particles having particle diameters ranging approximately from 1 microm to 15 microm have been characterized by flow/hyperlayer field-flow fractionation (FFF). The particle size accuracy has been improved significantly in this work by a second-order polynomial calibration. Very good agreement between the FFF data and scanning electron microscopic (SEM) results has been achieved. The effects of particle porosity, pore sizes, and particle sizes on the particle size accuracy in electrical sensing zone (ESZ) analyses have been discussed. It has been demonstrated by computer simulation and experimental measurements that false peaks can be generated in certain particle size regions when the static light scattering (SLS) technique is applied to tightly distributed spherical chromatographic support particles.

  1. Chromatographic retention behaviour, modelling and separation optimisation of the quaternary ammonium salt isometamidium chloride and related compounds on a range of reversed-phase liquid chromatographic stationary phases.

    Science.gov (United States)

    Schad, Gesa J; Euerby, Melvin R; Skellern, Graham G; Tettey, Justice N A

    2012-07-01

    This paper describes the reversed-phase liquid chromatographic behaviour of the trypanocidal quaternary ammonium salt isometamidium chloride and its related compounds on a range of liquid chromatographic phases possessing alkyl and phenyl ligands on the same inert silica. In a parallel study with various extended polar selectivity phases which possessed different hydrophobic/silanophilic (hydrogen bonding) activity ratios, the chromatographic retention/selectivities of the quaternary ammonium salts was shown to be due to a co-operative mechanism between hydrophobic and silanophilic interactions. The highly aromatic and planar isometamidium compounds were found to be substantially retained on stationary phases containing aromatic functionality via strong π-π interactions. The chemometric approach of principal component analysis was used to characterise the chromatographic behaviour of the isometamidium compounds on the differing phases and to help identify the dominant retention mechanism(s). Two-dimensional (temperature/gradient) retention modelling was employed to develop and optimise a rapid liquid chromatography method for the separation of the six quaternary ammonium salts within 2.5 min which would be suitable for bioanalysis using liquid chromatography-mass spectrometry. This is the first reported systematic study of the relationship between stationary phase chemistries and retention/selectivity for a group of quaternary ammonium salts.

  2. THE BUFFER CAPACITY OF AIRWAY EPITHELIAL SECRETIONS

    Directory of Open Access Journals (Sweden)

    Dusik eKim

    2014-06-01

    Full Text Available The pH of airway epithelial secretions influences bacterial killing and mucus properties and is reduced by acidic pollutants, gastric reflux, and respiratory diseases such as cystic fibrosis (CF. The effect of acute acid loads depends on buffer capacity, however the buffering of airway secretions has not been well characterized. In this work we develop a method for titrating micro-scale (30 µl volumes and use it to study fluid secreted by the human airway epithelial cell line Calu-3, a widely used model for submucosal gland serous cells. Microtitration curves revealed that HCO3- is the major buffer. Peak buffer capacity (β increased from 17 to 28 mM/pH during forskolin stimulation, and was reduced by >50% in fluid secreted by cystic fibrosis transmembrane conductance regulator (CFTR-deficient Calu-3 monolayers, confirming an important role of CFTR in HCO3- secretion. Back-titration with NaOH revealed non-volatile buffer capacity due to proteins synthesized and released by the epithelial cells. Lysozyme and mucin concentrations were too low to buffer Calu-3 fluid significantly, however model titrations of porcine gastric mucins at concentrations near the sol-gel transition suggest that mucins may contribute to the buffer capacity of ASL in vivo. We conclude that CFTR-dependent HCO3- secretion and epithelially-derived proteins are the predominant buffers in Calu-3 secretions.

  3. Building Partner Capacity

    Science.gov (United States)

    2015-02-01

    In a similar manner, globalization has also created new realities, such as in the case of food production where choice now affects demand as much as...quantity did in the past. “Two major factors drive food requirements [and market prices]: a growing global population and prosperity that expands...argued earlier, to expend effort in other nations without consideration of building capacity and resiliency risks strategic failure and wastage of

  4. Markets and Institutional Capacity

    DEFF Research Database (Denmark)

    Ingemann, Jan Holm

    2010-01-01

    Adequate explanations concerning the introduction of production and consumption of organic food in Denmark imply the necessity to engage a certain understanding of markets. Markets should subsequently not be seen as entities nor places but as complex relations between human actors. Further, the e......, the establishment, maintenance and development of markets are depending on the capacity of the actors to enter into continuous and enhancing interplay....

  5. Aerobic capacity in children and adolescents with cerebral palsy

    NARCIS (Netherlands)

    Verschuren, Olaf; Takken, Tim

    2010-01-01

    This study described the aerobic capacity [VO(2peak) (ml/kg/min)] in contemporary children and adolescents with cerebral palsy (CP) using a maximal exercise test protocol. Twenty-four children and adolescents with CP classified at Gross Motor Functional Classification Scale (GMFCS) level I or level

  6. Aerobic Capacity in Children and Adolescents with Cerebral Palsy

    Science.gov (United States)

    Verschuren, Olaf; Takken, Tim

    2010-01-01

    This study described the aerobic capacity [VO[subscript 2peak] (ml/kg/min)] in contemporary children and adolescents with cerebral palsy (CP) using a maximal exercise test protocol. Twenty-four children and adolescents with CP classified at Gross Motor Functional Classification Scale (GMFCS) level I or level II and 336 typically developing…

  7. Exercise capacity following pediatric heart transplantation: A systematic review.

    Science.gov (United States)

    Peterson, Sara; Su, Jennifer A; Szmuszkovicz, Jacqueline R; Johnson, Robert; Sargent, Barbara

    2017-08-01

    Pediatric HTs account for 13% of all HTs with >60% of recipients surviving at least 10 years post-HT. The purpose of this systematic review is to synthesize the literature on exercise capacity of pediatric HT recipients to improve understanding of the mechanisms that may explain the decreased exercise capacity. Six databases were searched for studies that compared the exercise capacity of HT recipients ≤21 years old with a control group or normative data. Sixteen studies were included. Pediatric HT recipients, as compared to controls or normative data, exhibit significantly higher resting HR, and at peak exercise exhibit significantly decreased HR, VO2 , power, work, minute ventilation, and exercise duration. Peak VO2 appears to improve within the first 2.5 years post-HT; peak work remains constant; and there is inconclusive evidence that peak HR, HR recovery, and HR reserve improve with time since HT. These results are discussed in the context of the mechanisms that may explain the impaired exercise capacity of pediatric HT recipients, including chronotropic incompetence, graft dysfunction, side effects of immunosuppression therapy, and deconditioning. In addition, the limited literature on rehabilitation after pediatric HT is summarized. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Aerobic Capacity in Children and Adolescents with Cerebral Palsy

    Science.gov (United States)

    Verschuren, Olaf; Takken, Tim

    2010-01-01

    This study described the aerobic capacity [VO[subscript 2peak] (ml/kg/min)] in contemporary children and adolescents with cerebral palsy (CP) using a maximal exercise test protocol. Twenty-four children and adolescents with CP classified at Gross Motor Functional Classification Scale (GMFCS) level I or level II and 336 typically developing…

  9. Aerobic capacity in children and adolescents with cerebral palsy

    NARCIS (Netherlands)

    Verschuren, Olaf; Takken, Tim

    2010-01-01

    This study described the aerobic capacity [VO(2peak) (ml/kg/min)] in contemporary children and adolescents with cerebral palsy (CP) using a maximal exercise test protocol. Twenty-four children and adolescents with CP classified at Gross Motor Functional Classification Scale (GMFCS) level I or level

  10. Peak Oxygen Uptake during and after Long-duration Space Flight

    Science.gov (United States)

    Moore, Alan D., Jr.; Downs, Meghan E.; Lee, Stuart M. C.; Feiveson, Alan H.; Knudsen, Poul; Evetts, Simon N.; Ploutz-Snyder, Lori

    2014-01-01

    Aerobic capacity (VO2peak) previously has not been measured during or after long-duration spaceflight. PURPOSE: To measure VO2peak and submaximal exercise responses during and after International Space Station (ISS) missions. METHODS: Astronauts (9 M, 5 F: 49 +/- 5 yr, 175 +/- 7 cm, 77.2 +/- 15.1 kg, 40.6 +/- 6.4 mL/kg/min [mean +/-SD]) performed graded peak cycle tests 90 days before spaceflight, 15 d (FD15) after launch and every 30 d thereafter during flight, and 1 (R+1), 10 (R+10), and 30 d (R+30) after landing. Oxygen consumption (VO2) and heart rate (HR) were measured from rest to peak exercise, while cardiac output (Q), stroke volume (SV), and arterial-venous oxygen difference (a-vO2diff) were measured only during rest and submaximal exercise. Data were analyzed using mixed-model linear regression. Body mass contributed significantly to statistical models, and thus results are reported as modeled estimates for an average subject. RESULTS: Early inflight (FD15) VO2peak was 17% lower (95% CI = - 22%, -13%) than preflight. VO2peak increased during spaceflight (0.001 L/min/d, P = 0.02) but did not return to preflight levels. On R+1 VO2peak was 15% (95% CI = -19%, -10%) lower than preflight but recovered to within 2% of preflight by R+30 (95% CI = -6%, +3%). Peak HR was not significantly different from preflight at any time. Inflight submaximal VO2 and a-vO2diff were generally lower than preflight, but the Q vs. VO2 slope was unchanged. In contrast, the SV vs. VO2 slope was lower (P < 0.001), primarily due to elevated SV at rest, and the HR vs. VO2 slope was greater (P < 0.001), largely due to elevated HR during more intense exercise. On R+1 although the relationships between VO2 and Q, SV, and HR were not statistically different than preflight, resting and submaximal exercise SV was lower (P < 0.001), resting and submaximal exercise HR was higher (P < 0.002), and a-vO2diff was unchanged. HR and SV returned to preflight levels by R+30. CONCLUSION: In the average

  11. Peak-power-point monitor for solar panel

    Science.gov (United States)

    Schloss, A. I.

    1972-01-01

    Attempt was made to determine solar cell panel peak power capability without disrupting power flow from panel. Separate solar cell strings were switched from panel circuits, and increasingly larger loads were added rapidly until peak power points were transversed. String wattage output was recorded and all stored string measurements summed together indicate peak power point in panel.

  12. Modeling neuroendocrine stress reactivity in salivary cortisol: adjusting for peak latency variability.

    Science.gov (United States)

    Lopez-Duran, Nestor L; Mayer, Stefanie E; Abelson, James L

    2014-07-01

    In this report, we present growth curve modeling (GCM) with landmark registration as an alternative statistical approach for the analysis of time series cortisol data. This approach addresses an often-ignored but critical source of variability in salivary cortisol analyses: individual and group differences in the time latency of post-stress peak concentrations. It allows for the simultaneous examination of cortisol changes before and after the peak while controlling for timing differences, and thus provides additional information that can help elucidate group differences in the underlying biological processes (e.g., intensity of response, regulatory capacity). We tested whether GCM with landmark registration is more sensitive than traditional statistical approaches (e.g., repeated measures ANOVA--rANOVA) in identifying sex differences in salivary cortisol responses to a psychosocial stressor (Trier Social Stress Test--TSST) in healthy adults (mean age 23). We used plasma ACTH measures as our "standard" and show that the new approach confirms in salivary cortisol the ACTH finding that males had longer peak latencies, higher post-stress peaks but a more intense post-peak decline. This finding would have been missed if only saliva cortisol was available and only more traditional analytic methods were used. This new approach may provide neuroendocrine researchers with a highly sensitive complementary tool to examine the dynamics of the cortisol response in a way that reduces risk of false negative findings when blood samples are not feasible.

  13. Peak alignment and robust principal component analysis of gas chromatograms of fatty acid methyl esters and volatiles

    DEFF Research Database (Denmark)

    Frosch, Stina; Jørgensen, Bo

    2007-01-01

    Gas chromatograms of fatty acid methyl esters and of volatile lipid oxidation products from fish lipid extracts are analyzed by multivariate data analysis [principal component analysis (PCA)]. Peak alignment is necessary in order to include all sampled points of the chromatograms in the data set....... The ability of robust algorithms to deal with outlier problems, including both sample-wise and element-wise outliers, and the advantages and drawbacks of two robust PCA methods, robust PCA (ROBPCA) and robust singular value decomposition when analysing these GC data were investigated. The results show...... that the usage of ROPCA is advantageous, compared with traditional PCA, when analysing the entire profile of chromatographic data in cases of sub-optimally aligned data. It also demonstrates how choosing the most robust PCA (sample or element-wise) depends on the type of outliers present in the data set....

  14. Exercise training induces similar elevations in the activity of oxoglutarate dehydrogenase and peak oxygen uptake in the human quadriceps muscle

    DEFF Research Database (Denmark)

    Blomstrand, Eva; Krustrup, Peter; Søndergaard, Hans

    2011-01-01

    During exercise involving a small muscle mass, peak oxygen uptake is thought to be limited by peripheral factors, such as the degree of oxygen extraction from the blood and/or mitochondrial oxidative capacity. Previously, the maximal activity of the Krebs cycle enzyme oxoglutarate dehydrogenase has...

  15. Chromatographic HPV-16 E6/E7 plasmid vaccine purification employing L-histidine and 1-benzyl-L-histidine affinity ligands.

    Science.gov (United States)

    Amorim, Lúcia F A; Gaspar, Rita; Pereira, Patrícia; Černigoj, Urh; Sousa, Fani; Queiroz, João António; Sousa, Ângela

    2017-07-06

    Affinity chromatography based on amino acids as interacting ligands was already indicated as an alternative compared to ion exchange or hydrophobic interaction for plasmid DNA purification. Understanding the recognition mechanisms occurring between histidine-based ligands and nucleic acids enables more efficient purification of a DNA vaccine, as the binding and elution conditions can be adjusted in order to enhance the purification performance. Decreasing pH to slightly acidic conditions increases the positive charge of histidine ligand, what influences the type of interaction between chromatographic support and analytes. This was proven in this work, where hydrophobic effects established in the presence of ammonium sulfate were affected at pH 5.0 in comparison to pH 8.0, while electrostatic and cation-π interactions were intensified. Histidine ligand at pH 5.0 interacts with phosphate groups or aromatic rings of plasmid DNA. Due to different responses of RNA and pDNA on mobile phase changes, the elution order between RNA and pDNA was changed with mobile phase pH decrease from 8.0 to 5.0. The phenomenon was more evident with L-histidine ligand due to more hydrophilic character, leading to an improved selectivity of L-histidine-modified chromatographic monolith, allowing the product recovery with 99% of purity (RNA removal). With the 1-benzyl- L-histidine ligand, stronger and less selective interactions with the nucleic acids were observed due to the additional hydrophobicity associated with the phenyl aromatic ring. Optimization of sample displacement chromatography parameters (especially (NH4 )2 SO4 concentration) at slightly acidic pH enabled excellent isolation of pDNA, by the removal of RNA in a negative mode, with binding capacities above 1.5 mg pDNA per mL of chromatographic support. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Ergodic Capacity of Cognitive Radio under Imperfect Channel State Information

    CERN Document Server

    Rezk, Zouheir

    2012-01-01

    A spectrum-sharing communication system where the secondary user is aware of the instantaneous channel state information (CSI) of the secondary link, but knows only the statistics and an estimated version of the secondary transmitter-primary receiver (ST-PR) link, is investigated. The optimum power profile and the ergodic capacity of the secondary link are derived for general fading channels (with continuous probability density function) under average and peak transmit-power constraints and with respect to two different interference constraints: an interference outage constraint and a signal-to-interference outage constraint. When applied to Rayleigh fading channels, our results show, for instance, that the interference constraint is harmful at high-power regime in the sense that the capacity does not increase with the power, whereas at low-power regime, it has a marginal impact and no-interference performance corresponding to the ergodic capacity under average or peak transmit power constraint in absence of ...

  17. Quantum reading capacity

    Science.gov (United States)

    Pirandola, Stefano; Lupo, Cosmo; Giovannetti, Vittorio; Mancini, Stefano; Braunstein, Samuel L.

    2011-11-01

    The readout of a classical memory can be modelled as a problem of quantum channel discrimination, where a decoder retrieves information by distinguishing the different quantum channels encoded in each cell of the memory (Pirandola 2011 Phys. Rev. Lett. 106 090504). In the case of optical memories, such as CDs and DVDs, this discrimination involves lossy bosonic channels and can be remarkably boosted by the use of nonclassical light (quantum reading). Here we generalize these concepts by extending the model of memory from single-cell to multi-cell encoding. In general, information is stored in a block of cells by using a channel-codeword, i.e. a sequence of channels chosen according to a classical code. Correspondingly, the readout of data is realized by a process of ‘parallel’ channel discrimination, where the entire block of cells is probed simultaneously and decoded via an optimal collective measurement. In the limit of a large block we define the quantum reading capacity of the memory, quantifying the maximum number of readable bits per cell. This notion of capacity is nontrivial when we suitably constrain the physical resources of the decoder. For optical memories (encoding bosonic channels), such a constraint is energetic and corresponds to fixing the mean total number of photons per cell. In this case, we are able to prove a separation between the quantum reading capacity and the maximum information rate achievable by classical transmitters, i.e. arbitrary classical mixtures of coherent states. In fact, we can easily construct nonclassical transmitters that are able to outperform any classical transmitter, thus showing that the advantages of quantum reading persist in the optimal multi-cell scenario.

  18. Comprehensive two-dimensional gas chromatographic separations with a temperature programmed microfabricated thermal modulator.

    Science.gov (United States)

    Collin, William R; Nuñovero, Nicolas; Paul, Dibyadeep; Kurabayashi, Katsuo; Zellers, Edward T

    2016-04-29

    Comprehensive two-dimensional gas chromatography (GC×GC) with a temperature-programmed microfabricated thermal modulator (μTM) is demonstrated. The 0.78 cm(2), 2-stage μTM chip with integrated heaters and a PDMS coated microchannel was placed in thermal contact with a solid-state thermoelectric cooler and mounted on top of a bench scale GC. It was fluidically coupled through heated interconnects to an upstream first-dimension ((1)D) PDMS-coated capillary column and a downstream uncoated capillary or second-dimension ((2)D) PEG-coated capillary. A mixture of n-alkanes C6-C10 was separated isothermally and the full-width-at-half-maximum (fwhm) values of the modulated peaks were assessed as a function of the computer-controlled minimum and maximum stage temperatures of μTM, Tmin and Tmax, respectively. With Tmin and Tmax fixed at -25 and 100°C, respectively, modulated peaks of C6 and C7 had fwhm valuesthermal modulator. Replacing the PDMS phase in the μTM with a trigonal-tricationic room temperature ionic liquid eliminated the bleed observed with the PDMS, but also reduced the capacity for several test compounds. Regardless, the demonstrated capability to independently temperature program this low resource μTM enhances its versatility and its promise for use in bench-scale GC×GC systems.

  19. Enhancing human capacities

    CERN Document Server

    Savulescu, Julian; Kahane, Guy

    2011-01-01

    Enhancing Human Capacities is the first to review the very latest scientific developments in human enhancement. It is unique in its examination of the ethical and policy implications of these technologies from a broad range of perspectives. Presents a rich range of perspectives on enhancement from world leading ethicists and scientists from Europe and North America The most comprehensive volume yet on the science and ethics of human enhancement Unique in providing a detailed overview of current and expected scientific advances in this area Discusses both general conceptual and ethical issues

  20. Chromatographic finger print analysis of Naringi crenulata by HPTLC technique

    Institute of Scientific and Technical Information of China (English)

    Subramanian Sampathkumar; Ramakrishnan N

    2011-01-01

    Objective:To establish the fingerprint profile of Naringi crenulata (N. crenulata) (Roxb.) Nicols. using high performance thin layer chromatography (HPTLC) technique. Methods: Preliminary phytochemical screening was done and HPTLC studies were carried out. CAMAG HPTLC system equipped with Linomat V applicator, TLC scanner 3, Reprostar 3 and WIN CATS-4 software was used. Results: The results of preliminary phytochemical studies confirmed the presence of protein, lipid, carbohydrate, reducing sugar, phenol, tannin, flavonoid, saponin, triterpenoid, alkaloid, anthraquinone and quinone. HPTLC finger printing of ethanolic extract of stem revealed 10 spots with Rf values in the range of 0.08 to 0.65;bark showed 8 peaks with Rf values in the range of 0.07 to 0.63 and the ethanol extract of leaf revealed 8 peaks with Rf values in the range of 0.09 to 0.49, respectively. The purity of sample was confirmed by comparing the absorption spectra at start, middle and end position of the band. Conclusions:It can be concluded that HPTLC finger printing of N. crenulata may be useful in differentiating the species from the adulterant and act as a biochemical marker for this medicinally important plant in the pharmaceutical industry and plant systematic studies.

  1. Development and validation of a simple stability-indicating high performance liquid chromatographic method for the determination of miconazole nitrate in bulk and cream formulations.

    Science.gov (United States)

    De Zan, María M; Cámara, María S; Robles, Juan C; Kergaravat, Silvina V; Goicoechea, Héctor C

    2009-08-15

    A simple and stability-indicating high performance liquid chromatographic method was developed and validated for the determination of miconazole nitrate in bulk and cream preparations. The extraction step for cream samples consisted in a warming, cooling and centrifugation procedure that assures the elimination of the lipophilic matrix component, in order to avoid further precipitation in the chromatographic system. Separation was achieved on a ZORBAX Eclipse XDB - C18 (4.6 mm x 150 mm, 5 microm particle size) column, using a mobile phase consisting of water, methanol and acetonitrile, in a flow and solvent gradient elution for 15 min. The column was maintained at 25 degrees C and 10 microL of solutions were injected. UV detection was performed at 232 nm, although employment of a diode array detector allowed selectivity confirmation by peak purity evaluation. The method was validated reaching satisfactory results for selectivity, precision and accuracy. Degradation products in naturally aged samples could be simultaneously evaluated, without interferences in the quantitative analysis.

  2. Validation and application of reversed phase high-performance liquid chromatographic method for quantification of pizotifen malate in pharmaceutical solid dosage formulations.

    Science.gov (United States)

    Rahman, Shaikh Mukidur; Lutfulkabir, Abulkalam; Jahan, M D Arshad; Momen, A Z M Ruhul; Rouf, Abushara Shamsur

    2010-10-01

    The aim of this study was to develop and validate an isocratic reversed phase high-performance liquid chromatographic method for quantification of pizotifen malate in pharmaceutical solid dosage formulations. Good chromatographic separation of pizotifen malate was achieved by using an analytical column, C(18) ODS column. The system was operated at 40°C oven temperature using a mobile phase consisting of acetonitrile and acetate buffer pH 7.0 (60:40) at a flow rate of 2 ml/min. The method showed high sensitivity with good linearity (r(2)= 0.99997) over the tested concentration range of 0.0020-0.0300 mg/ml for pizotifen malate. Detection was carried out at 231 nm and retention time was 2.838 min. Placebo and blank studies were performed and no peak was observed at the retention time of pizotifen malate. The intermediate precision and accuracy results (mean ± RSD, n=3) were (99.11±0.21) % and (99.19±0.55) % respectively with tailing factor (1.26±0.19). The proposed method was validated in terms of selectivity, linearity, accuracy, precision, range, detection and quantitation limit, system suitability and solution stability.This method can be successfully employed for simultaneous quantitative analysis of pizotifen malate in pharmaceutical solid dosage formulations.

  3. Parallel development of chromatographic and mass-spectrometric methods for quantitative analysis of glycation on an IgG1 monoclonal antibody.

    Science.gov (United States)

    Viski, Kornél; Gengeliczki, Zsolt; Lenkey, Krisztián; Baranyáné Ganzler, Katalin

    2016-10-01

    Monitoring post-translational modifications (PTMs) in biotherapeutics is of paramount importance. In pharmaceutical industry, chromatography with optical detection is the standard choice of quantitation of product related impurities; and mass spectrometry is used only for characterization. Parallel development of a boronate affinity chromatographic (BAC) and a mass spectrometric methods for quantitative measurement of glycation on a monoclonal antibody (mAb) shed light on the importance of certain characteristics of the individual methods. Non-specific interactions in BAC has to be suppressed with the so-called shielding reagent. We have found that excessive amount of shielding reagents in the chromatographic solvents may cause significant underestimation of glycation. Although contamination of the retained peak with the non-glycated isoforms in BAC is unavoidable, our work shows that it can be characterized and quantitated by mass spectrometry. It has been demonstrated that glycation can be measured by mass spectrometry at the intact protein level with an LOQ value of 3.0% and error bar of ±0.5%. The BAC and MS methods have been found to provide equivalent results. These methods have not been compared from these points of view before.

  4. Kinetic simulation of complex decomposition as a tool for the ion chromatographic determination of elemental speciation of less inert metal ions.

    Science.gov (United States)

    Winter, Christian; Seubert, Andreas

    2016-01-15

    Species decomposition is an often occurring artefact during the chromatographic determination of elemental speciation. The decomposition follows a simple path to lower coordinated compounds. Therefore a simulation is developed for those decomposition reactions. The simulation separates the isochronal processes of the separation itself and the ongoing reaction and delivers thermodynamic and kinetic information about the species present in the original sample. This shifts the boundaries of separation based elemental speciation to less inert metal ions which are typically not analyzable by this approach. The less inert gallium monooxalato complex [GaOx](+) is used as example for testing the simulation software as this complex decomposes only to Ga(3+) and both species are retained on cation exchange columns. We extracted thermodynamic and kinetic information from flow rate experiments by the analysis of the peak areas in the chromatogram. The results show that some of our assumptions such as the irreversibility under the applied chromatographic conditions are not ultimately true, but good accordance of simulation and measured data was achieved.

  5. Ionic liquids as porogens in the microwave-assisted synthesis of methacrylate monoliths for chromatographic application

    Energy Technology Data Exchange (ETDEWEB)

    Singco, Brenda; Lin, Chen-Lan; Cheng, Yi-Jie; Shih, Yung-Han [Department of Chemistry and Center for Nanotechnology, CYCU (Chung Yuan Christian University), 200 Chung Pei Road, Chung-Li 320, Taiwan (China); Huang, Hsi-Ya, E-mail: hyhuang@cycu.edu.tw [Department of Chemistry and Center for Nanotechnology, CYCU (Chung Yuan Christian University), 200 Chung Pei Road, Chung-Li 320, Taiwan (China)

    2012-10-09

    Highlights: Black-Right-Pointing-Pointer An efficient and cleaner monoliths preparation utilizing ionic liquids in conjunction with microwave Black-Right-Pointing-Pointer These ionic liquids with varied cation alkyl chain and anion type successfully tuned the morphology of different alkyl methacrylates Black-Right-Pointing-Pointer Small molecules and peptide digests separated well in these monoliths. - Abstract: Several imidazolium-based ionic liquids (ILs) with varying cation alkyl chain length (C{sub 4}-C{sub 10}) and anion type (tetrafluoroborate ([BF{sub 4}]{sup -}), hexafluorophosphate ([PF{sub 6}]{sup -}) and bis(trifluoromethylsulfonyl)imide ([Tf{sub 2}N]{sup -})) were used as reaction media in the microwave polymerization of methacrylate-based stationary phases. Scanning electron micrographs and backpressures of poly(butyl methacrylate-ethylene dimethacrylate) (poly(BMA-EDMA)) monoliths synthesized in the presence of these ionic liquids demonstrated that porosity and permeability decreased when cation alkyl chain length and anion hydrophobicity were increased. Performance of these monoliths was assessed for their ability to separate parabens by capillary electrochromatography (CEC). Intra-batch precision (n = 3 columns) for retention time and peak area ranged was 0.80-1.13% and 3.71-4.58%, respectively. In addition, a good repeatability of RSD{sub Retentiontime} = <0.30% and {approx}1.0%, RSD{sub Peakarea} = <1.30% and <4.3%, and RSD{sub Efficiency} = <0.6% and <11.5% for intra-day and inter-day, respectively exemplify monolith performance reliability for poly(BMA-EDMA) fabricated using 1-hexyl-3-methylimidazolium tetrafluoroborate ([C{sub 6}mim][BF{sub 4}]) porogen. This monolith was also tested for its potential in nanoLC to separate protein digests in gradient mode. ILs as porogens also fabricated different alkyl methacrylate (AMA) (C4-C18) monoliths. Furthermore, employing binary IL porogen mixture such as 1-butyl-3-methylimidazolium tetrafluoroborate

  6. Chromatographic and Spectrophotometric Analysis of Phenolic Compounds from Fruits of Libidibia ferrea Martius.

    Science.gov (United States)

    Ferreira, Magda R A; Fernandes, Mônica T M; da Silva, Wliana A V; Bezerra, Isabelle C F; de Souza, Tatiane P; Pimentel, Maria F; Soares, Luiz A L

    2016-05-01

    Libidibia ferrea (Mart. ex Tul.) L.P. Queiroz (Fabaceae) is a tree which is native to Brazil, widely known as "Jucá," where its herbal derivatives are used in folk medicine with several therapeutic properties. The constituents, which have already been described in the fruit, are mainly hydrolysable tannins (gallic acid [GA] and ellagic acid [EA]). The aim of this study was to investigate the phenolic variability in the fruit of L. ferrea by ultraviolet/visible (UV/VIS) and chromatographic methods (high-performance liquid chromatography [HPLC]/high-performance thin layer chromatography [HPTLC]). Several samples were collected from different regions of Brazil and the qualitative (fingerprints by HPTLC and HPLC) and quantitative analysis (UV/VIS and HPLC) of polyphenols were performed. The HPTLC and HPLC profiles allowed separation and identification of both major analytical markers: EA and GA. The chemical profiles were similar in a number of spots or peaks for the samples, but some differences could be observed in the intensity or area of the analytical markers for HPTLC or HPLC, respectively. Regarding the quantitative analysis, the polyphenolic content by UV/VIS ranged from 13.99 to 37.86 g% expressed as GA or from 10.75 to 29.09 g% expressed as EA. The contents of EA and GA by liquid chromatography-reversed phase (LC-RP) method ranged from 0.57 to 2.68 g% and from 0.54 to 3.23 g%, respectively. The chemical profiles obtained by HPTLC or HPLC, as well as the quantitative analysis by spectrophotometry or LC-RP method, were suitable for discrimination of each herbal sample and can be used as tools for the comparative analysis of the fruits from L. ferrea. The polyphenols of fruits of Libidibia ferrea can be quantified by UV/VIS and HPLCThe HPLC method was able to detect the gallic and ellagic acids in several samples of fruits of Libidibia ferreaThe phenolic profiles of fruits from Libidibia ferrea by HPTLC and HPLC were reproductible. Abbreviations used: HPTLC

  7. Microstructure-based analysis and simulation of flow and mass transfer in chromatographic stationary phases

    Science.gov (United States)

    Koku, Harun

    Limitations of mass transfer in chromatographic bioseparations employing traditional packed particles have fuelled the inception and development of alternative stationary phases with improved performance characteristics. This work investigates case studies in two categories of these alternative media, namely polymer-modified packed particles and continuous monolithic phases, for insight into their enhanced properties. Specifically, high-resolution microscopy techniques and image-based analysis algorithms were implemented to extract morphology information for these materials, in an attempt to elucidate the relation between microstructure and performance. For the monolith, mesoscopic simulation methods were also employed for a more rigorous analysis of the flow and dispersion behavior. Scanning and transmission electron microscopy images of the commercial polymer-modified, agarose-based particle Sepharose XL were compared to those for its unmodified counterpart, Sepharose FF. Local regions in the composite dextran-agarose Sepharose XL particles were noted to exhibit a denser network of fibers and smaller pore sizes overall, compared to those in the traditional Sepharose FF particles. Images of particles equilibrated with high concentrations of protein revealed a significant difference in protein localization patterns, with the stained protein in XL occupying a markedly higher area fraction of the images. This suggests a higher volume available for adsorption and provides visual clues into how the consistently higher static capacity of these polymer-modified particles is manifested. Treatment of the XL particles with dextranase, an enzyme that breaks down dextran, resulted in a reduction of protein coverage, providing evidence that it is indeed the dextran that is responsible for the improved static capacity in this polymer-modified stationary phase. Imaging and image analysis techniques were also used to analyze the commercial CIM(TM) disk monolith. Two- and three

  8. The formation of peak rings in large impact craters.

    Science.gov (United States)

    Morgan, Joanna V; Gulick, Sean P S; Bralower, Timothy; Chenot, Elise; Christeson, Gail; Claeys, Philippe; Cockell, Charles; Collins, Gareth S; Coolen, Marco J L; Ferrière, Ludovic; Gebhardt, Catalina; Goto, Kazuhisa; Jones, Heather; Kring, David A; Le Ber, Erwan; Lofi, Johanna; Long, Xiao; Lowery, Christopher; Mellett, Claire; Ocampo-Torres, Rubén; Osinski, Gordon R; Perez-Cruz, Ligia; Pickersgill, Annemarie; Poelchau, Michael; Rae, Auriol; Rasmussen, Cornelia; Rebolledo-Vieyra, Mario; Riller, Ulrich; Sato, Honami; Schmitt, Douglas R; Smit, Jan; Tikoo, Sonia; Tomioka, Naotaka; Urrutia-Fucugauchi, Jaime; Whalen, Michael; Wittmann, Axel; Yamaguchi, Kosei E; Zylberman, William

    2016-11-18

    Large impacts provide a mechanism for resurfacing planets through mixing near-surface rocks with deeper material. Central peaks are formed from the dynamic uplift of rocks during crater formation. As crater size increases, central peaks transition to peak rings. Without samples, debate surrounds the mechanics of peak-ring formation and their depth of origin. Chicxulub is the only known impact structure on Earth with an unequivocal peak ring, but it is buried and only accessible through drilling. Expedition 364 sampled the Chicxulub peak ring, which we found was formed from uplifted, fractured, shocked, felsic basement rocks. The peak-ring rocks are cross-cut by dikes and shear zones and have an unusually low density and seismic velocity. Large impacts therefore generate vertical fluxes and increase porosity in planetary crust. Copyright © 2016, American Association for the Advancement of Science.

  9. The formation of peak rings in large impact craters

    Science.gov (United States)

    Morgan, Joanna V.; Gulick, Sean P. S.; Bralower, Timothy; Chenot, Elise; Christeson, Gail; Claeys, Philippe; Cockell, Charles; Collins, Gareth S.; Coolen, Marco J. L.; Ferrière, Ludovic; Gebhardt, Catalina; Goto, Kazuhisa; Jones, Heather; Kring, David A.; Le Ber, Erwan; Lofi, Johanna; Long, Xiao; Lowery, Christopher; Mellett, Claire; Ocampo-Torres, Rubén; Osinski, Gordon R.; Perez-Cruz, Ligia; Pickersgill, Annemarie; Poelchau, Michael; Rae, Auriol; Rasmussen, Cornelia; Rebolledo-Vieyra, Mario; Riller, Ulrich; Sato, Honami; Schmitt, Douglas R.; Smit, Jan; Tikoo, Sonia; Tomioka, Naotaka; Urrutia-Fucugauchi, Jaime; Whalen, Michael; Wittmann, Axel; Yamaguchi, Kosei E.; Zylberman, William

    2016-11-01

    Large impacts provide a mechanism for resurfacing planets through mixing near-surface rocks with deeper material. Central peaks are formed from the dynamic uplift of rocks during crater formation. As crater size increases, central peaks transition to peak rings. Without samples, debate surrounds the mechanics of peak-ring formation and their depth of origin. Chicxulub is the only known impact structure on Earth with an unequivocal peak ring, but it is buried and only accessible through drilling. Expedition 364 sampled the Chicxulub peak ring, which we found was formed from uplifted, fractured, shocked, felsic basement rocks. The peak-ring rocks are cross-cut by dikes and shear zones and have an unusually low density and seismic velocity. Large impacts therefore generate vertical fluxes and increase porosity in planetary crust.

  10. Deficiency of employability capacity

    Directory of Open Access Journals (Sweden)

    Pelse I.

    2012-10-01

    Full Text Available Young unemployed people have comprised one of the significantly largest groups of the unemployed people in Latvia in recent years. One of the reasons why young people have difficulty integrating into the labour market is the “expectation gap” that exists in the relations between employers and the new generation of workers. Employers focus on capacity-building for employability such individual factors as strength, patience, self-discipline, self-reliance, self-motivation, etc., which having a nature of habit and are developed in a long-term work socialization process, which begins even before the formal education and will continue throughout the life cycle. However, when the socialization is lost, these habits are depreciated faster than they can be restored. Currently a new generation is entering the labour market, which is missing the succession of work socialization. Factors, such as rising unemployment and poverty in the background over the past twenty years in Latvia have created a very unfavourable employability background of “personal circumstances” and “external factors”, which seriously have impaired formation of the skills and attitudes in a real work environment. The study reveals another paradox – the paradox of poverty. Common sense would want to argue that poverty can be overcome by the job. However, the real state of affairs shows that unfavourable coincidence of the individual, personal circumstances and external factors leads to deficit of employability capacity and possibility of marked social and employment deprivation.

  11. Heat Capacity in Proteins

    Science.gov (United States)

    Prabhu, Ninad V.; Sharp, Kim A.

    2005-05-01

    Heat capacity (Cp) is one of several major thermodynamic quantities commonly measured in proteins. With more than half a dozen definitions, it is the hardest of these quantities to understand in physical terms, but the richest in insight. There are many ramifications of observed Cp changes: The sign distinguishes apolar from polar solvation. It imparts a temperature (T) dependence to entropy and enthalpy that may change their signs and which of them dominate. Protein unfolding usually has a positive ΔCp, producing a maximum in stability and sometimes cold denaturation. There are two heat capacity contributions, from hydration and protein-protein interactions; which dominates in folding and binding is an open question. Theoretical work to date has dealt mostly with the hydration term and can account, at least semiquantitatively, for the major Cp-related features: the positive and negative Cp of hydration for apolar and polar groups, respectively; the convergence of apolar group hydration entropy at T ≈ 112°C; the decrease in apolar hydration Cp with increasing T; and the T-maximum in protein stability and cold denaturation.

  12. Development of immunoaffinity chromatographic method for Ara h 2 isolation.

    Science.gov (United States)

    Wu, Zhihua; Zhang, Ying; Zhan, Shaode; Lian, Jun; Zhao, Ruifang; Li, Kun; Tong, Ping; Li, Xin; Yang, Anshu; Chen, Hongbing

    2017-03-01

    Ara h 2 is considered a major allergen in peanut. Due to the difficulty of separation, Ara h 2 had not been fully studied. Immunoaffinity chromatography (IAC) column can separate target protein with high selectivity, which made it possible to purify Ara h 2 from different samples. In this study, IAC method was developed to purify Ara h 2 and its effect was evaluated. By coupling polyclonal antibody (pAb) on CNBr-activated Sepharose 4B, the column for specific extraction was constructed. The coupling efficiency of the IAC column was higher than 90%, which made the capacity of column reached 0.56 mg per 0.15 g medium (dry weight). The recovery of Ara h 2 ranged from 93% to 100% for different concentrations of pure Ara h 2 solutions in 15 min. After using a column 10 times, about 88% of the column capacity remained. When applied to extract Ara h 2 from raw peanut protein extract and boiled peanut protein extract, the IAC column could recovery 94% and 88% target protein from the mixture. SDS-PAGE and Western blotting analysis confirmed the purified protein was Ara h 2, its purity reached about 90%. Significantly, the IAC column could capture dimer of Ara h 2, which made it feasible to prepared derivative of protein after processing. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Automatic Peak Selection by a Benjamini-Hochberg-Based Algorithm

    KAUST Repository

    Abbas, Ahmed

    2013-01-07

    A common issue in bioinformatics is that computational methods often generate a large number of predictions sorted according to certain confidence scores. A key problem is then determining how many predictions must be selected to include most of the true predictions while maintaining reasonably high precision. In nuclear magnetic resonance (NMR)-based protein structure determination, for instance, computational peak picking methods are becoming more and more common, although expert-knowledge remains the method of choice to determine how many peaks among thousands of candidate peaks should be taken into consideration to capture the true peaks. Here, we propose a Benjamini-Hochberg (B-H)-based approach that automatically selects the number of peaks. We formulate the peak selection problem as a multiple testing problem. Given a candidate peak list sorted by either volumes or intensities, we first convert the peaks into p-values and then apply the B-H-based algorithm to automatically select the number of peaks. The proposed approach is tested on the state-of-the-art peak picking methods, including WaVPeak [1] and PICKY [2]. Compared with the traditional fixed number-based approach, our approach returns significantly more true peaks. For instance, by combining WaVPeak or PICKY with the proposed method, the missing peak rates are on average reduced by 20% and 26%, respectively, in a benchmark set of 32 spectra extracted from eight proteins. The consensus of the B-H-selected peaks from both WaVPeak and PICKY achieves 88% recall and 83% precision, which significantly outperforms each individual method and the consensus method without using the B-H algorithm. The proposed method can be used as a standard procedure for any peak picking method and straightforwardly applied to some other prediction selection problems in bioinformatics. The source code, documentation and example data of the proposed method is available at http://sfb.kaust.edu.sa/pages/software.aspx. © 2013

  14. Automatic peak selection by a Benjamini-Hochberg-based algorithm.

    Directory of Open Access Journals (Sweden)

    Ahmed Abbas

    Full Text Available A common issue in bioinformatics is that computational methods often generate a large number of predictions sorted according to certain confidence scores. A key problem is then determining how many predictions must be selected to include most of the true predictions while maintaining reasonably high precision. In nuclear magnetic resonance (NMR-based protein structure determination, for instance, computational peak picking methods are becoming more and more common, although expert-knowledge remains the method of choice to determine how many peaks among thousands of candidate peaks should be taken into consideration to capture the true peaks. Here, we propose a Benjamini-Hochberg (B-H-based approach that automatically selects the number of peaks. We formulate the peak selection problem as a multiple testing problem. Given a candidate peak list sorted by either volumes or intensities, we first convert the peaks into [Formula: see text]-values and then apply the B-H-based algorithm to automatically select the number of peaks. The proposed approach is tested on the state-of-the-art peak picking methods, including WaVPeak [1] and PICKY [2]. Compared with the traditional fixed number-based approach, our approach returns significantly more true peaks. For instance, by combining WaVPeak or PICKY with the proposed method, the missing peak rates are on average reduced by 20% and 26%, respectively, in a benchmark set of 32 spectra extracted from eight proteins. The consensus of the B-H-selected peaks from both WaVPeak and PICKY achieves 88% recall and 83% precision, which significantly outperforms each individual method and the consensus method without using the B-H algorithm. The proposed method can be used as a standard procedure for any peak picking method and straightforwardly applied to some other prediction selection problems in bioinformatics. The source code, documentation and example data of the proposed method is available at http://sfb.kaust.edu.sa/pages/software.aspx.

  15. Chromatographic Methods for the Analysis of Polyphenols in Wines

    Directory of Open Access Journals (Sweden)

    Medić-Šarić, M.

    2009-03-01

    Full Text Available Wine is an excellent source of various classes of polyphenols, including phenolic acids, flavonoids, and trihydroxystilbene resveratrol (Fig.1. Polyphenols play a major role in wine quality since they contribute to the sensory characteristics of wine, particularly color and astringency. A recent interest in these substances has been stimulated by abundant evidence of their beneficial effects on human health, such as anticarcinogenic, antiinflamatory and antimicrobial activities. Therefore, numerous studies have been performed in the attempt to analyze polyphenols in wine. This paper reviews the current advances in the determination of polyphenols in wine by the major chromatographic techniques such as thin-layer chromatography (TLC and high-performance liquid chromatography (HPLC.The great complexity of the polyphenolic content of wine and the difficulty in obtaining some of the standards usually require sample preparation before analysis. Two methods for sample preparation, liquid-liquid extraction and solid-phase extraction, are most commonly applied. Hydrolysis is applied frequently, but not exclusively, to remove the sugar moieties from glycosides.TLC on silica gel plates is useful for the rapid and low-cost separation and identification of the polyphenols present in wine (Fig. 2. Densitometric quantitative analysis of polyphenols in wine extracts is usually performed by scanning the TLC plates with UV light at wavelengths of 350–365 nm or 250–260 nm (Fig. 3. For the evaluation of the most efficient mobile phase and an optimal choice of the combination of two or more mobile phases, two methods may be applied: information theory and numerical taxonomy. HPLC currently represents the most popular technique for the analysis of polyphenols in wine. For this purpose, a reversed-phase HPLC method that uses gradient elution with binary elution system is usually employed. Routine detection is based on measurement of UV-Vis absorption with a diode

  16. Renewal of an old European Pharmacopoeia method for Terazosin using modeling with mass spectrometric peak tracking.

    Science.gov (United States)

    Kormány, Róbert; Molnár, Imre; Fekete, Jenő

    2017-02-20

    An older method for terazosin was reworked in order to reduce the analysis time from 90min (2×45min) to below 5min. The method in European Pharmacopoeia (Ph.Eur.) investigates the specified impurities separately. The reason of the different methods is that the retention of two impurities is not adequate in reversed phase, not even with 100% water. Therefore ion-pair-chromatography has to be applied and since that two impurities absorb at low UV-wavelength they had to be analyzed by different method than the other specified impurities. In our new method we could improve the retention with pH elevation using a new type of stationary phases available for high pH applications. Also a detection wavelength could be selected that is appropriate for the detection and quantification of all impurities. The method development is the bottleneck of liquid chromatography even today, when more and more fast chromatographic systems are used. Expert knowledge with intelligent programs is available to reduce the time of method development and offer extra information about the robustness of the separation. Design of Experiments (DoE) for simultaneous optimization of gradient time (tG), temperature (T) and ternary eluent composition (tC) requires 12 experiments. A good alternative way to identify a certain peak in different chromatograms is the molecular mass of the compound, due to its high specificity. Liquid Chromatography-Mass Spectrometry (LC-MS) is now a routine technique and increasingly available in laboratories. In our experiment for the resolution- and retention modeling the DryLab4 method development software (Version 4.2) was used. In recent versions of the software the use of (m/z)-MS-data is possible along the UV-peak-area-tracking technology. The modelled and measured chromatograms showed excellent correlations. The average retention time deviations were ca. 0.5s and there was no difference between the predicted and measured Rs,crit -values.

  17. Application of a stability-indicating thin-layer chromatographic method to the determination of tenatoprazole in pharmaceutical dosage forms.

    Science.gov (United States)

    Dhaneshwar, Sunil R; Bhusari, Vidhya K; Mahadik, Mahadeo V; Santakumari, B

    2009-01-01

    A sensitive, selective, precise, and stability-indicating thin-layer chromatographic (TLC) method was developed and validated for the determination of tenatoprazole both as a bulk drug and in formulation. The method uses TLC aluminum plates precoated with Silica Gel 60F-254 as the stationary phase and the solvent system toluene-ethyl acetate-methanol (6 + 4 + 1, v/v/v). This system gave compact spots for tenatoprazole (Rf value of 0.34 +/- 0.02). Tenatoprazole was subjected to acid and alkali hydrolysis, oxidation, and photodegradation. The peaks of the degradation products were well-resolved from that of the pure drug and had significantly different Rf values. Densitometric analysis of tenatoprazole was performed in the absorbance mode at 306 nm. The linear regression analysis data for the calibration plots showed a good linear relationship over the concentration range of 100-1500 ng/spot. The mean values of the correlation coefficient, slope, and intercept were 0.9989 +/- 1.42, 10.27 +/- 0.965, and 4894.2 +/- 1.24, respectively. The method was validated for precision, robustness, and recovery. The limit of detection and limit of quantitation were 50 and 100 ng/spot, respectively. Statistical analysis showed that the method is repeatable and selective for estimation of tenatoprazole. Because the method can separate the drug from its degradation products, it can be used to monitor stability.

  18. Combined column-mobile phase mixture statistical design optimization of high-performance liquid chromatographic analysis of multicomponent systems.

    Science.gov (United States)

    Breitkreitz, Márcia C; Jardim, Isabel C S F; Bruns, Roy E

    2009-02-27

    A statistical approach for the simultaneous optimization of the mobile and stationary phases used in reversed-phase liquid chromatography is presented. Mixture designs using aqueous mixtures of acetonitrile (ACN), methanol (MeOH) and tetrahydrofuran (THF) organic modifiers were performed simultaneously with column type optimization, according to a split-plot design, to achieve the best separation of compounds in two sample sets: one containing 10 neutral compounds with similar retention factors and another containing 11 pesticides. Combined models were obtained by multiplying a linear model for column type, C8 or C18, by quadratic or special cubic mixture models. Instead of using an objective response function, combined models were built for elementary chromatographic criteria (retention factors, resolution and relative retention) of each solute or pair of solutes and, after their validation, the global separation was accomplished by means of Derringer's desirability functions. For neutral compounds a 37:12:8:43 (v/v/v/v) percentage mixture of ACN:MeOH:THF:H2O with the C18 column and for pesticides a 15:15:70 (v/v/v) ACN:THF:H2O mixture with the C8 column provide excellent resolution of all peaks.

  19. Development and validation of high-performance thin layer chromatographic method for ursolic acid in Malus domestica peel

    Directory of Open Access Journals (Sweden)

    P H Nikam

    2013-01-01

    Full Text Available Ursolic acid, a pentacyclic triterpenoid possess a wide range of pharmacological activities. It shows hypoglycemic, antiandrogenic, antibacterial, antiinflammatory, antioxidant, diuretic and cynogenic activity. It is commonly present in plants especially coating of leaves and fruits, such as apple fruit, vinca leaves, rosemary leaves, and eucalyptus leaves. A simple high-performance thin layer chromatographic method has been developed for the quantification of ursolic acid from apple peel (Malus domestica. The samples dissolved in methanol and linear ascending development was carried out in twin trough glass chamber. The mobile phase was selected as toluene:ethyl acetate:glacial acetic acid (70:30:2. The linear regression analysis data for the calibration plots showed good linear relationship with r 2 =0.9982 in the concentration range 0.2-7 ΅g/spot with respect to peak area. According to the ICH guidelines the method was validated for linearity, accuracy, precision, and robustness. Statistical analysis of the data showed that the method is reproducible and selective for the estimation of ursolic acid.

  20. Development and Validation of High-performance Thin Layer Chromatographic Method for Ursolic Acid in Malus domestica Peel.

    Science.gov (United States)

    Nikam, P H; Kareparamban, J A; Jadhav, A P; Kadam, V J

    2013-07-01

    Ursolic acid, a pentacyclic triterpenoid possess a wide range of pharmacological activities. It shows hypoglycemic, antiandrogenic, antibacterial, antiinflammatory, antioxidant, diuretic and cynogenic activity. It is commonly present in plants especially coating of leaves and fruits, such as apple fruit, vinca leaves, rosemary leaves, and eucalyptus leaves. A simple high-performance thin layer chromatographic method has been developed for the quantification of ursolic acid from apple peel (Malus domestica). The samples dissolved in methanol and linear ascending development was carried out in twin trough glass chamber. The mobile phase was selected as toluene:ethyl acetate:glacial acetic acid (70:30:2). The linear regression analysis data for the calibration plots showed good linear relationship with r(2)=0.9982 in the concentration range 0.2-7 μg/spot with respect to peak area. According to the ICH guidelines the method was validated for linearity, accuracy, precision, and robustness. Statistical analysis of the data showed that the method is reproducible and selective for the estimation of ursolic acid.

  1. Quantitative Mass spectrometric Analysis of Ropivacaine and Bupivacaine in Authentic, Pharmaceutical and Spiked Human Plasma without Chromatographic Separation

    Directory of Open Access Journals (Sweden)

    Nahla N. Salama

    2009-01-01

    Full Text Available The present study employs time of flight mass spectrometry for quantitative analysis of the local anesthetic drugs ropivacaine and bupivacaine in authentic, pharmaceutical and spiked human plasma as well as in the presence of their impurities 2,6-dimethylaniline and alkaline degradation product. The method is based on time of flight electron spray ionization mass spectrometry technique without preliminary chromatographic separation and makes use of bupivacaine as internal standard for ropivacaine, which is used as internal standard for bupivacaine. A linear relationship between drug concentrations and the peak intensity ratio of ions of the analyzed substances is established. The method is linear from 23.8 to 2380.0 ng mL-1 for both drugs. The correlation coefficient was ≥0.996 in authentic and spiked human plasma. The average percentage recoveries in the ranges of 95.39%–102.75% was obtained. The method is accurate (% RE < 5% and reproducible with intra- and inter-assay precision (RSD% < 8.0%. The quantification limit is 23.8 ng mL-1 for both drugs. The method is not only highly sensitive and selective, but also simple and effective for determination or identification of both drugs in authentic and biological fluids. The method can be applied in purity testing, quality control and stability monitoring for the studied drugs.

  2. Development and validation of a reversed phase liquid chromatographic method for analysis of oxytetracycline and related impurities.

    Science.gov (United States)

    Kahsay, Getu; Shraim, Fairouz; Villatte, Philippe; Rotger, Jacques; Cassus-Coussère, Céline; Van Schepdael, Ann; Hoogmartens, Jos; Adams, Erwin

    2013-03-05

    A simple, robust and fast high-performance liquid chromatographic method is described for the analysis of oxytetracycline and its related impurities. The principal peak and impurities are all baseline separated in 20 min using an Inertsil C₈ (150 mm × 4.6 mm, 5 μm) column kept at 50 °C. The mobile phase consists of a gradient mixture of mobile phases A (0.05% trifluoroacetic acid in water) and B (acetonitrile-methanol-tetrahydrofuran, 80:15:5, v/v/v) pumped at a flow rate of 1.3 ml/min. UV detection was performed at 254 nm. The developed method was validated for its robustness, sensitivity, precision and linearity in the range from limit of quantification (LOQ) to 120%. The limits of detection (LOD) and LOQ were found to be 0.08 μg/ml and 0.32 μg/ml, respectively. This method allows the separation of oxytetracycline from all known and 5 unknown impurities, which is better than previously reported in the literature. Moreover, the simple mobile phase composition devoid of non-volatile buffers made the method suitable to interface with mass spectrometry for further characterization of unknown impurities. The developed method has been applied for determination of related substances in oxytetracycline bulk samples available from four manufacturers. The validation results demonstrate that the method is reliable for quantification of oxytetracycline and its impurities.

  3. Ultra-high performance liquid chromatographic determination of antioxidants in teas using inkjet-printed graphene-polyaniline electrode.

    Science.gov (United States)

    Bardpho, Chayanee; Rattanarat, Poomrat; Siangproh, Weena; Chailapakul, Orawon

    2016-02-01

    A development of ultra-high performance liquid chromatographic coupled with a novel inkjet-printed conductive ink-modified electrode for a fast and simultaneous determination of polyphenolic antioxidants was achieved. Two printing techniques were selected for fabrication and modification including (i) an in-house screen-printing method and (ii) an inkjet-printing method, respectively. A conductive ink containing graphene and polyaniline nanocomposite (G-PANI) was precisely casted onto the surface of screen-printed carbon electrode (SPCE) using a dimatix inkjet material printer. Compared to a bare SPCE, the G-PANI-modified screen-printed carbon electrode (G-PANI/SPCE) exhibited higher electrochemical sensitivity with increase (2-4 times) of peak current of each antioxidant. Moreover, four antioxidants were successfully separated and determined within 3 min using a reverse phase ultra-high performance liquid chromatography (UHPLC) with a mobile phase containing phosphate buffer and acetonitrile (90:10 v/v). Under an optimal detection potential at +1.2V vs. Ag/AgCl, linear calibrations and limits of detection (S/N=3) for antioxidants were found to be 0.01-10 µg mL(-1) and 1.38-1.94 ng mL(-1), respectively. Finally, this proposed method has been successfully used for the determination of antioxidants in tea samples, the results obtained from our presented method were within a highly good agreement those obtained from a standard UHPLC-UV method.

  4. Optimal Power Allocation for Fading Channels in Cognitive Radio Networks: Ergodic Capacity and Outage Capacity

    CERN Document Server

    Kang, Xin; Nallanathan, Arumugam; Garg, Hari Krishna; Zhang, Rui

    2008-01-01

    A cognitive radio network (CRN) is formed by either allowing the secondary users (SUs) in a secondary communication network (SCN) to opportunistically operate in the frequency bands originally allocated to a primary communication network (PCN) or by allowing SCN to coexist with the primary users (PUs) in PCN as long as the interference caused by SCN to each PU is properly regulated. In this paper, we consider the latter case, known as spectrum sharing, and study the optimal power allocation strategies to achieve the ergodic capacity and the outage capacity of the SU fading channel under different types of power constraints and fading channel models. In particular, besides the interference power constraint at PU, the transmit power constraint of SU is also considered. Since the transmit power and the interference power can be limited either by a peak or an average constraint, various combinations of power constraints are studied. It is shown that there is a capacity gain for SU under the average over the peak ...

  5. Chromatographic generator systems for the actinides and natural decay series elements

    Energy Technology Data Exchange (ETDEWEB)

    McAlister, D.R.; Horwitz, E.P. [PG Research Foundation, Lisle, IL (United States)

    2011-07-01

    This work describes chromatographic radionuclide generator systems for the production of actinides and natural decay series elements. The generator systems begin with alpha emitting parent radioisotopes with half-lives (T{sub 1/2}) of greater than one year and produce alpha or beta emitting radioisotopes with half-lives of hours to days. Chromatographic systems were chosen to minimize radiolytic damage to chromatographic supports, preserve the parent activity for repeated use, provide high purity daughter radionuclide tracers, and to minimize or eliminate the need for evaporation of solutions of the parent or daughter nuclides. Useful secondary separations involving the daughters of the initial parent radionuclide are also described. Separation systems for {sup 210}Bi, {sup 210}Po, {sup 211}Pb, {sup 212}Pb, {sup 223}Ra, {sup 224}Ra, {sup 225}Ra, {sup 225}Ac, {sup 227}Th, {sup 228}Th, {sup 231}Th, {sup 234}Th, and {sup 239}Np are outlined in detail. (orig.)

  6. High-separation performance of chromatographic capillaries coated with MOF-5 by the controlled SBU approach.

    Science.gov (United States)

    Münch, Alexander S; Seidel, Jürgen; Obst, Anja; Weber, Edwin; Mertens, Florian O R L

    2011-09-19

    Recently developed MOF surface-coating techniques, the controlled SBU approach (CSA) for the generation of MOF-5, and the use of self-assembled monolayers have been combined to generate a wall-bonded, crosslinked stationary phase for gas chromatographic capillary columns displaying excellent performance in the separation of natural gas components. The chromatographic performance of this new type of column has been compared to the state-of-the-art solution for this separation problem, namely a coated silica column of the porous layer open tubular (PLOT) type. Chromatographic parameters such as separation, resolution, and tailing factors, as well as plate numbers and heights in the case of isothermal operation, have been determined. Kinetic and thermodynamic parameters characterizing the analyte-stationary phase interaction have been determined for various C1-C4 analytes.

  7. Chromatographic immunoassays: strategies and recent developments in the analysis of drugs and biological agents.

    Science.gov (United States)

    Matsuda, Ryan; Rodriguez, Elliott; Suresh, Doddavenkatanna; Hage, David S

    2015-01-01

    A chromatographic immunoassay is a technique in which an antibody or antibody-related agent is used as part of a chromatographic system for the isolation or measurement of a specific target. Various binding agents, detection methods, supports and assay formats have been developed for this group of methods, and applications have been reported that range from drugs, hormones and herbicides to peptides, proteins and bacteria. This review discusses the general principles and applications of chromatographic immunoassays, with an emphasis being given to methods and formats that have been developed for the analysis of drugs and biological agents. The relative advantages or limitations of each format are discussed. Recent developments and research in this field, as well as possible future directions, are also considered.

  8. [Use of LKhM-80 chromatograph in the analysis of urinary steroids].

    Science.gov (United States)

    Orlov, E N; Antipov, E M

    1995-01-01

    The paper describes a simple way of updating a Russian production-type LKaM-80 chromatograph in order to make a gas chromatographic analysis of urinary steroids for separation by using high performance capillary columns. To connect capillary columns, the units consisting of a gas heaving T-joint, a stream separating chamber, and a releasing restrictor were applied. To achieve satisfactory results, it is necessary to place a column through the tube connecting the union for attachment of the column and the flame-ionization detector so that the end of a capillary should be located at the detector as soon as closer. The updated chromatograph has been successfully used to obtain urinary steroidal profiles which are essential for the differential diagnosis of causes of hyperandrogyny in females, including pregnants.

  9. Study of Tea Digitized Chromatographic Fingerprint Spectra Using Micellar Electrokinetic Chromatography

    Institute of Scientific and Technical Information of China (English)

    SONG, Guan-Qun; LIN, Jin-Ming; QU, Feng; DONG, Wen-Ju

    2003-01-01

    This paper described the principle of digitized chromatographic fingerprint spectrum and established digitized chromatographic fingerprint spectra of ten brands of Chinese famous tea by the micellar electrokinetic chromatography. This work was done using a 25 mmol. L- 1 sodium dodecylsulfate in a 20 mmol· L-1borate (pH 7.0) solution as running buffer, 20 kV applied potential and detection at 280 nm. The chromatographic fingerprint spectra were digitized by the relative retention value (α)and the relative area (Sr), and were analyzed to identify the tea samples. In the absence of the standard samples, the present method was easy setup and inexpensive, and provided the applicable information for the quality assessment of teas.

  10. SYSTEM IDENTIFICATION METHOD OF LINEAR AND NON—LINEAR LIQUID PREPARATIVE CHROMATOGRAPHIC SEPARATION

    Institute of Scientific and Technical Information of China (English)

    ShuWenli; LiZhong; 等

    1997-01-01

    The paper proposes the identification method of linear and non-linear chromatographic system.Isotherms and lumped mass transfer coefficients of chromatography separating isomer sorbitol and mannitol on D80 adsorbent are determined.The analyses of root mean square error of chromatography elution curves are carried out.The results show that the system studied is non-linear and the theoretical elution curves of the non-linear chromatographic model are more accurate than those of the linear chromatographic model,Results of parameter sensitivity analyses show that elution curves of non-linear chromatopraphic separation aremore sensitive to the variation of parameter “ai” in the adsorption isotherms Qi=Ci*/(ai+biCi*) than to the variation of parameter "bi”as well as lumped mass transfer coefficients.

  11. A review on sample preparation and chromatographic determination of acephate and methamidophos in

    Directory of Open Access Journals (Sweden)

    Vijay Kumar

    2015-09-01

    Full Text Available Acephate and its metabolite methamidophos are common organophosphorus insecticide used for crop protection. High uses of acephate and methamidophos have induced health issues and environmental pollution. Their undesired presence in the environment is creating ecotoxicology and may harm human health. It is therefore essential to detect the presence of acephate and methamidophos even in trace level. In this review, we have tried to accommodate successful methods of detection of acephate and methamidophos in the different biological media. Their recovery and residue analysis in different media such as vegetables, human and animal tissues have also included. The most common method for their determination is based on chromatographic separation and identification. Among different chromatographic methods, LC and GC coupled with different detectors have used. But, they both need extensive pretreatment and cleanup procedure, before undergoing chromatographic separation and identification. LC coupled with mass spectrometry (LCMS is sometime able to detect acephate and methamidophos in ppm level.

  12. Optimization of the gas chromatographic separations; Optimacion de las separaciones cromatograficas en fase gaseosa

    Energy Technology Data Exchange (ETDEWEB)

    Gasco Sanchez, L.

    1973-07-01

    A review and a critical study on the optimization of the gas chromatographic separations are made. After dealing with the fundamental gas chromatographic equations, some methods of expressing column performances are discussed: performance indices, performance parameters, resolution and effective plate number per unit time. This is completed with a comparative study on performances of various types of columns. Moreover, optimization methods for operating chromatographic conditions are extensively dealt with: as resolution optimization, separation time, and normalization techniques for the time of analysis in order to achieve the maximum resolution at constant time. Finally, some others non operating parameters such as: selectivity of stationary phases, column preparation and optimization methods by means of computers are studied. (Author) 68 refs.

  13. Transesterification of propylene glycol methyl ether in chromatographic reactors using anion exchange resin as a catalyst.

    Science.gov (United States)

    Oh, Jungmin; Sreedhar, Balamurali; Donaldson, Megan E; Frank, Timothy C; Schultz, Alfred K; Bommarius, Andreas S; Kawajiri, Yoshiaki

    2016-09-30

    Reactive chromatography using an anion exchange resin is proposed for a transesterification reaction of propylene glycol methyl ether (DOWANOL™ PM) with ethyl acetate to produce propylene glycol methyl ether acetate (DOWANOL™ PMA). This reaction is studied in batch and chromatographic reactors catalyzed by an anion exchange resin. Several anion exchange resins are tested and compared based on the performance of resin as an adsorbent and a catalyst. A chromatographic column is packed with a selected catalyst, AMBERLITE™ IRA904, and both reaction and chromatographic elution are studied at different temperatures and feed concentrations. The resulting chromatograms are fitted to a mathematical model to obtain adsorption equilibrium and reaction kinetic parameters by the inverse method. Compared to esterification investigated in a previous study, transesterification has advantages such as a higher conversion at lower temperature and easy removal of the byproduct which may lead to higher productivity. Deactivation of anion exchange resins is observed and potential solutions are suggested.

  14. Workshop on moisture buffer capacity

    DEFF Research Database (Denmark)

    2003-01-01

    Summary report of a Nordtest workshop on moisture buffer capacity held at Copenhagen August 21-22 2003......Summary report of a Nordtest workshop on moisture buffer capacity held at Copenhagen August 21-22 2003...

  15. Big Change in PF Capacity

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    @@ Paraformaldehyde (PF) production in China has grown to a considerable scale today. The total capacity was around 90 thousand t/a in 2006. Since 2007, the production capacity of PF has increased drastically.

  16. Synthesis of metronidazole-imprinted molecularly imprinted polymers by distillation precipitation polymerization and their use as a solid-phase adsorbent and chromatographic filler.

    Science.gov (United States)

    Liu, Jiang; Zhang, Lu; Li Han Song, Le; Liu, Yuan; Tang, Hui; Li, Yingchun

    2015-04-01

    Metronidazole-imprinted polymers with superior recognition properties were prepared by a novel strategy called distillation-precipitation polymerization. The as-obtained polymers were characterized by Fourier-transform infrared spectroscopy, laser particle size determination and scanning electron microscopy, and their binding performances were evaluated in detail by static, kinetic and dynamic rebinding tests, and Scatchard analysis. The results showed that when the fraction of the monomers was 5 vol% in the whole reaction system, the prepared polymers afforded good morphology, monodispersity, and high adsorption capacity and excellent selectivity to the target molecule, metronidazole. The optimal binding performance is 12.41 mg/g for metronidazole just before leakage occurred and 38.51 mg/g at saturation in dynamic rebinding tests. Metronidazole-imprinted polymers were further applied as packing agents in solid-phase extraction and as chromatographic filler, both of which served for the detection of metronidazole in fish tissue. The results illustrated the recoveries of spiked samples ranged from 82.97 to 87.83% by using molecularly imprinted solid-phase extraction combined with a C18 commercial column and 93.7 to 101.2% by directly using the polymer-packed chromatographic column. The relative standard deviation of both methods was less than 6%.

  17. Metal-organic-framework-based tandem molecular sieves as a dual platform for selective microextraction and high-resolution gas chromatographic separation of n-alkanes in complex matrixes.

    Science.gov (United States)

    Chang, Na; Gu, Zhi-Yuan; Wang, He-Fang; Yan, Xiu-Ping

    2011-09-15

    Metal-organic frameworks (MOFs) were employed to design tandem molecular sieves as a dual platform for selective solid-phase microextraction (SPME) and high-resolution gas chromatographic (GC) separation of target analytes in complex matrixes. An elegant combination of a ZIF-8-coated fiber for SPME with a ZIF-8-coated capillary for GC allows selective extraction and separation of n-alkanes from complex matrixes such as petroleum-based fuel and biological fluids. The proposed tandem ZIF-8 molecular sieves not only offered good enhancement factors from 235 (hexane) to 1212 (nonane), but also exhibited wide linearity with 3 orders of magnitude for the tested linear alkanes. The limits of detection for the linear alkanes ranged from 0.46 ng L(-1) (nonane) to 1.06 ng L(-1)(hexane). The relative standard deviations of retention time, peak area, peak height, and half peak width for five replicate determinations of the tested n-alkanes at 30 ng L(-1) were 0.02-0.26%, 1.9-8.6%, 1.4-6.0%, and 1.3-7.2%, respectively. The developed tandem ZIF-8 molecular sieves were further used for the determination of linear alkanes in petroleum-based fuel and human serum. The large diversity in structure and pore size allows various combinations of MOFs for designing an MOF-based tandem molecular sieve platform to achieve different selectivities in extraction and chromatographic separation and to solve headache problems in complex real sample analysis.

  18. Landfill Construction and Capacity Expansion

    NARCIS (Netherlands)

    Andre, F.J.; Cerda, E.

    2003-01-01

    We study the optimal capacity and lifetime of landfills taking into account their sequential nature.Such an optimal capacity is characterized by the so-called Optimal Capacity Condition.Particular versions of this condition are obtained for two alternative settings: first, if all the landfills are t

  19. Chromatographic determination of the radiochemical purity of [[sup 131]I]MIBG [metaiodobenzylguanidine] infusion fluids: a comparison and discussion of the chromatographic characteristics using three different techniques

    Energy Technology Data Exchange (ETDEWEB)

    Wafelman, A.R.; Beijnen, J.H. (Slotervaart Hospital, Amsterdam (Netherlands). Hospital Pharmacy Nederlands Kanker Inst. ' Antoni van Leeuwenhoekhuis' , Amsterdam (Netherlands)); Hoefnagel, C.A. (Nederlands Kanker Inst. ' Antoni van Leeuwenhoekhuis' , Amsterdam (Netherlands))

    1993-05-01

    This paper proposes a reproducible and validated assay based on solid phase extraction for the determination of the level of free [[sup 131]I]iodide in [[sup 131]I]metaiodobenzylguanidine infusion fluids. The method has been compared with HPLC and TLC assays. Furthermore, a TLC system is introduced that allows the separation between metaiodobenzylguanidine, its chemical precursor metaiodobenzylamine and iodide. Attention is paid to the chromatographic characteristics of the analytes, with a discussion of the possible retention mechanisms. (Author).

  20. Reference Values for Peak Exercise Cardiac Output in Healthy Individuals.

    Science.gov (United States)

    Agostoni, Piergiuseppe; Vignati, Carlo; Gentile, Piero; Boiti, Costanza; Farina, Stefania; Salvioni, Elisabetta; Mapelli, Massimo; Magrì, Damiano; Paolillo, Stefania; Corrieri, Nicoletta; Sinagra, Gianfranco; Cattadori, Gaia

    2017-06-01

    Cardiac output (Q˙) is a key parameter in the assessment of cardiac function, its measurement being crucial for the diagnosis, treatment, and prognostic evaluation of all heart diseases. Until recently, Q˙ determination at peak exercise has been possible through invasive methods, so that normal values were obtained in studies based on small populations. Nowadays, peak Q˙ can be measured noninvasively by means of the inert gas rebreathing (IGR) technique. The present study was undertaken to provide reference values for peak Q˙ in the normal general population and to obtain a formula able to estimate peak exercise Q˙ from measured peak oxygen uptake (V˙o2). We studied 500 normal subjects (age, 44.9 ± 1.5 years; range, 18-77 years; 260 men, 240 women) who underwent a maximal cardiopulmonary exercise test with peak Q˙ measurement by IGR. In the overall study sample, peak Q˙ was 13.2 ± 3.5 L/min (men, 15.3 ± 3.3 L/min; women, 11.0 ± 2.0 L/min; P exercise was (4.4 × peak V˙o2) + 4.3 in the overall study cohort, (4.3 × peak V˙o2) + 4.5 in men, and (4.9 × peak V˙o2) + 3.6 in women. The simultaneous measurement of Q˙ and V˙o2 at peak exercise in a large sample of healthy subjects provided an equation to predict peak Q˙ from peak V˙o2 values. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.