WorldWideScience

Sample records for chromatographic mass spectrometric

  1. Liquid chromatographic-mass spectrometric method for ...

    African Journals Online (AJOL)

    Tropical Journal of Pharmaceutical Research ... Purpose: To develop and validate a simple, efficient and reliable Liquid chromatographic-mass spectrometric (LC-MS/MS) method for the quantitative determination of two dermatological drugs, ... By Country · List All Titles · Free To Read Titles This Journal is Open Access.

  2. The gas-chromatographic and gas-chromatographic-mass-spectrometric identification of halogen-containing organic compounds

    Science.gov (United States)

    Gidaspov, B. V.; Zenkevich, I. G.; Rodin, A. A.

    1989-09-01

    The problem of identifying halogen-containing organic compounds in their gas-chromatographic and gas-chromatographic-mass-spectrometric (GC-MS) determination in different materials has been examined. Particular attention has been paid not to the complete characterisation of methods for carrying out this analysis but to the most important problem of increasing the selectivity at the stages of sampling, separation, and interpretation of the gas-chromatographic and GC-MS information. The bibliography contains 292 references.

  3. A gas/liquid chromatographic-mass spectrometric method for the rapid screening of 250 pesticides in aqueous matrices

    Energy Technology Data Exchange (ETDEWEB)

    Chandramouli, B.; Harvan, D.; Brittain, S.; Hass, R. [Eno River Labs, LLC. Durham, NC (United States)

    2004-09-15

    Pesticide residues in food present a potentially serious and significant cause for concern. Many pesticides have been associated with significant health effects to the nervous and endocrine systems and some have been deemed carcinogenic. There are many well-established techniques for pesticide analysis. However, commercial pesticide methods have traditionally only been available for specific pesticide families, such as chlorinated pesticides or herbicides, and at detection limits ranging from 0.05 ppb to 1 ppm in aqueous matrices. Techniques that can quickly screen for the presence/absence of pesticide residues in food matrices are critical in ensuring the safety of food and water. This paper outlines a combined Gas Chromatographic-High Resolution Mass Spectrometric (GC-HRMS) and Liquid Chromatographic Tandem Mass Spectrometric (LC-MS/MS) screening assay for 250 pesticides that was developed for use in water, and soda samples at screening levels ranging from 0.1-5 ppb. The pesticides selected have been identified by the European Union as being of concern and the target of possible legislation. The list encompasses a variety of pesticide classes and compound groupings.

  4. Mass spectrometric protein characterization in proteome analysis using GELoader tip micro-columns packed with various chromatographic material

    International Nuclear Information System (INIS)

    Larsen, M.R.

    2001-01-01

    In the early 90'ies mass spectrometry (MS) was introduced as a tool for identifying proteins in protein sequence databases. Since then it has become an integrated tool in protein characterization and is today routinely used to identify proteins separated by gel electrophoresis. A two-tiered mass spectrometric protein identification strategy has recently been proposed. In the first strategy peptide mass maps obtained from the protein of interest are compared with theoretically derived peptide mass maps from proteins in protein sequence databases. If the protein cannot be identified by this strategy, tandem mass spectrometric sequencing is used to generate enough sequence data to identify the protein in protein sequence databases or expressed sequence tag (EST) databases. However, the above strategies primarily identify a protein relatively to the DNA sequence, in which no information about e.g. post-translational modifications (PTMs) is stored. PTMs are known to modify the function, location, solubility and activity of proteins in the cell, and they are therefore very important for understanding living cells. More than 200 different PTMs are known, of which glycosylation, phosphorylation and proteolytic processing are the most common ones. Mass spectrometric analysis of PTMs on gel-separated proteins requires a higher amount of protein than for identification only. In addition, higher sequence coverage from the peptide mass maps or pre-purification of the modified peptides prior to MS analysis, is necessary for detection of putative modified peptides. In this study a multi-tiered strategy, in which GELoader tip micro-columns packed with increasingly more hydrophobic chromatographic material are used in combination with mass spectrometry, is described. The ultimate aim was to gain increased sequence coverage from peptide mixtures derived from gel-separated proteins, in order to locate modified peptides. Graphite powder is described as an alternative to traditional

  5. Gas chromatographic/mass spectrometric determination of carbon isotope composition in unpurified samples: methamphetamine example.

    Science.gov (United States)

    Low, I A; Liu, R H; Legendre, M G; Piotrowski, E G; Furner, R L

    1986-10-01

    A gas chromatograph/quadrupole mass spectrometer system, operated in electron impact/selected ion monitoring mode, is used to determine the intensity ratio of the m/z 59 and the m/z 58 ions of the [C3H8N]+ fragment derived from methamphetamine samples synthesized with varying amounts of 13C-labeled methylamine. Crude products are introduced into the gas chromatograph without prior cleanup. The ratios measured were in excellent agreement with those calculated. A change in 0.25% use of 13C-methylamine is sufficient for product differentiation. The feasibility of using isotope labeling and subsequent mass spectrometric isotope ratio measurement as the basis of a compound tracing mechanism is discussed. Specifically, if methamphetamine samples manufactured from legal sources are asked to incorporate distinct 13C compositions, their sources can be traced when samples are diverted into illegal channels. Samples derived from illicit preparations can also be traced if the manufacturers of a precursor (methylamine in this case) incorporate distinct 13C compositions in their products.

  6. INTERLABORATORY STUDY OF A THERMOSPRAY-LIQUID CHROMATOGRAPHIC/MASS SPECTROMETRIC METHOD FOR SELECTED N-METHYL CARBAMATES, N-METHYL CARBAMOYLOXIMES, AND SUBSTITUTED UREA PESTICIDES

    Science.gov (United States)

    A thermospray-liquid chromatographic/mass spectrometric (TS-LC/MS) method was evaluated in an interlaboratory study for determining 3 N-methyl carbamates (bendiocarb, carbaryl, and carbofuran), 3-N-methyl carbamoyloximes (aldicarb, methomyl, and oxamyl), 2 substituted urea pestic...

  7. Structure elucidation of metabolite x17299 by interpretation of mass spectrometric data.

    Science.gov (United States)

    Zhang, Qibo; Ford, Lisa A; Evans, Anne M; Toal, Douglas R

    2017-01-01

    A major bottleneck in metabolomic studies is metabolite identification from accurate mass spectrometric data. Metabolite x17299 was identified in plasma as an unknown in a metabolomic study using a compound-centric approach where the associated ion features of the compound were used to determine the true molecular mass. The aim of this work is to elucidate the chemical structure of x17299, a new compound by de novo interpretation of mass spectrometric data. An Orbitrap Elite mass spectrometer was used for acquisition of mass spectra up to MS 4 at high resolution. Synthetic standards of N,N,N -trimethyl-l-alanyl-l-proline betaine (l,l-TMAP), a diastereomer, and an enantiomer were chemically prepared. The planar structure of x17299 was successfully proposed by de novo mechanistic interpretation of mass spectrometric data without any laborious purification and nuclear magnetic resonance spectroscopic analysis. The proposed structure was verified by deuterium exchanged mass spectrometric analysis and confirmed by comparison to a synthetic standard. Relative configuration of x17299 was determined by direct chromatographic comparison to a pair of synthetic diastereomers. Absolute configuration was assigned after derivatization of x17299 with a chiral auxiliary group followed by its chromatographic comparison to a pair of synthetic standards. The chemical structure of metabolite x17299 was determined to be l,l-TMAP.

  8. OpenChrom: a cross-platform open source software for the mass spectrometric analysis of chromatographic data.

    Science.gov (United States)

    Wenig, Philip; Odermatt, Juergen

    2010-07-30

    Today, data evaluation has become a bottleneck in chromatographic science. Analytical instruments equipped with automated samplers yield large amounts of measurement data, which needs to be verified and analyzed. Since nearly every GC/MS instrument vendor offers its own data format and software tools, the consequences are problems with data exchange and a lack of comparability between the analytical results. To challenge this situation a number of either commercial or non-profit software applications have been developed. These applications provide functionalities to import and analyze several data formats but have shortcomings in terms of the transparency of the implemented analytical algorithms and/or are restricted to a specific computer platform. This work describes a native approach to handle chromatographic data files. The approach can be extended in its functionality such as facilities to detect baselines, to detect, integrate and identify peaks and to compare mass spectra, as well as the ability to internationalize the application. Additionally, filters can be applied on the chromatographic data to enhance its quality, for example to remove background and noise. Extended operations like do, undo and redo are supported. OpenChrom is a software application to edit and analyze mass spectrometric chromatographic data. It is extensible in many different ways, depending on the demands of the users or the analytical procedures and algorithms. It offers a customizable graphical user interface. The software is independent of the operating system, due to the fact that the Rich Client Platform is written in Java. OpenChrom is released under the Eclipse Public License 1.0 (EPL). There are no license constraints regarding extensions. They can be published using open source as well as proprietary licenses. OpenChrom is available free of charge at http://www.openchrom.net.

  9. Gas Chromatographic Mass Spectrometric Determination of Myo-inositol in Humans Utilizing a Deuterated Internal Standard

    DEFF Research Database (Denmark)

    Andersen, Jan Rud; Larsen, Elfinn; Harbo, Helge

    1982-01-01

    The isotopic dilution technique was used for determining the content of myo-inositol in human urine, plasma and haemolysed erythrocyte samples. A deuterated myo-inositol, synthesized from inosose-2 by base-catalysed exchange of hydrogens by deuterium, followed by reduction of the inosose with 2H2......, was added as internal standard to the samples at an early stage in the analytical procedure. After separation and derivatization to the hexa-acetate, the gas chromatographic mass spectrometric analysis was carried out. A 25 m fused silica capillary column coated with methyl silicone was used, and the ions...... selected for monitoring were m/z 210 and m/z 214, which are characteristic and abundant fragment ions from unlabelled and hexadeuterated myo-inositolhexa-acetate, respectively. Calibration curves from water, urine, plasma and haemolysed erythrocytes show parallel, linear responses in the ratio between...

  10. Characterization of plant polysaccharides from Dendrobium officinale by multiple chromatographic and mass spectrometric techniques.

    Science.gov (United States)

    Ma, Huiying; Zhang, Keke; Jiang, Qing; Dai, Diya; Li, Hongli; Bi, Wentao; Chen, David Da Yong

    2018-04-27

    Plant polysaccharides have numerous medicinal functions. Due to the differences in their origins, regions of production, and cultivation conditions, the quality and the functions of polysaccharides can vary significantly. They are macromolecules with large molecular weight (MW) and complex structure, and pose great challenge for the analytical technology used. Taking Dendrobium officinale (DO) from various origins and locations as model samples. In this investigation, mechanochemical extraction method was used to successfully extract polysaccharides from DO using water as solvent, the process is simple, fast (40 s) and with high yield. The MWs of the intact saccharides from calibration curve and light scattering measurement were determined and compared after separation with size exclusion chromatography (SEC). The large polysaccharide was acid hydrolyzed to oligosaccharides and the products were efficiently separated and identified using liquid chromatography coupled to a high resolution tandem mass spectrometry (LC-MS 2 ). Obvious differences were observed among LC-MS 2 chromatograms of digested products, and the chemical structures for the products were proposed based on accurate mass values. More importantly, isomeric digested carbohydrate compounds were explored and characterized. All the chromatographic and mass spectrometric results in this study provided a multi-dimensional characterization, fingerprint analysis, and molecular structure level assessment of plant polysaccharides. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Gas chromatographic-mass spectrometric determination of hydrophilic compounds in environmental water by solid-phase extraction with activated carbon fiber felt.

    Science.gov (United States)

    Kawata, K; Ibaraki, T; Tanabe, A; Yagoh, H; Shinoda, A; Suzuki, H; Yasuhara, A

    2001-03-09

    Simple gas chromatographic-mass spectrometric determination of hydrophilic organic compounds in environmental water was developed. A cartridge containing activated carbon fiber felt was made by way of trial and was evaluated for solid-phase extraction of the compounds in water. The hydrophilic compounds investigated were acrylamide, N,N-dimethylacetamide, N,N-dimethylformamide, 1,4-dioxane, furfural, furfuryl alcohol, N-nitrosodiethylamine and N-nitrosodimethylamine. Overall recoveries were good (80-100%) from groundwater and river water. The relative standard deviations ranged from 4.5 to 16% for the target compounds. The minimum detectable concentrations were 0.02 to 0.03 microg/l. This method was successfully applied to several river water samples.

  12. Gas chromatography of organic microcontaminants using atomic emission and mass spectrometric detection combined in one instrument (GC-AED/MS)

    NARCIS (Netherlands)

    Mol, H.G.J.; Hankemeier, T.; Brinkman, U.A.T.

    1999-01-01

    This study describes the coupling of an atomic-emission detector and mass-spectrometric detector to a single gas chromatograph. Splitting of the column effluent enables simultaneous detection by atomic-emission detection (AED) and mass spectrometry (MS) and yields a powerful system for the target

  13. A liquid chromatography-mass spectrometric method for the determination of oak moss allergens atranol and chloroatranol in perfumes

    DEFF Research Database (Denmark)

    Bossi, Rossana; Rastogi, Suresh Chandra; Bernard, Guillaume

    2004-01-01

    This paper describes a validated liquid chromatographic-tandem mass spectrometric method for quantitative analysis of the potential oak moss allergens atranol and chloroatranol in perfumes and similar products. The method employs LC-MS-MS with electrospray ionization (ESI) in negative mode...

  14. Mass Spectrometric Analysis of Synthetic Organic Pigments.

    Science.gov (United States)

    Sugaya, Naeko; Takahashi, Mitsuko; Sakurai, Katsumi; Tanaka, Nobuko; Okubo, Ichiro; Kawakami, Tsuyoshi

    2018-04-18

    Though synthetic organic colorants are used in various applications nowadays, there is the concern that impurities by-produced during the manufacturing and degradation products in some of these colorants are persistent organic pollutants and carcinogens. Thus, it is important to identify the synthetic organic colorants in various products, such as commercial paints, ink, cosmetics, food, textile, and plastics. Dyes, which are soluble in water and other solvents, could be analyzed by chromatographic methods. In contrast, it is difficult to analyze synthetic organic pigments by these methods because of their insolubility. This review is an overview of mass spectrometric analysis of synthetic organic pigments by various ionization methods. We highlight a recent study of textile samples by atmospheric pressure solid analysis probe MS. Furthermore, the mass spectral features of synthetic organic pigments and their separation from other components such as paint media and plasticizers are discussed.

  15. Liquid chromatographic-tandem mass spectrometric assay for ...

    African Journals Online (AJOL)

    Methods: Blood and urine samples were obtained from healthy volunteers who admitted to not being on any medications. The investigated analytes were chromatographically separated on a C18 column (Luna®-PFP 100Å column, 50 mm × 2.0 mm i.d., 3.0 μm) with the aid of a mobile phase containing A; acetonitrile (ACN) ...

  16. Characterization of organic and conventional sweet basil leaves using chromatographic and flow-injection mass spectrometric (FIMS) fingerprints combined with principal component analysis

    Science.gov (United States)

    Lu, Yingjian; Gao, Boyan; Chen, Pei; Charles, Denys; Yu, Liangli (Lucy)

    2014-01-01

    Sweet basil, Ocimum basilicum., is one of the most important and wildly used spices and has been shown to have antioxidant, antibacterial, and anti-diarrheal activities. In this study, high performance liquid chromatographic (HPLC) and flow-injection mass spectrometric (FIMS) fingerprinting techniques were used to differentiate organic and conventional sweet basil leaf samples. Principal component analysis (PCA) of the fingerprints indicated that both HPLC and FIMS fingerprints could effectively detect the chemical differences in the organic and conventional sweet basil leaf samples. This study suggested that the organic basil sample contained greater concentrations of almost all the major compounds than its conventional counterpart on a per same botanical weight basis. The FIMS method was able to rapidly differentiate the organic and conventional sweet basil leaf samples (1 min analysis time), whereas the HPLC fingerprints provided more information about the chemical composition of the basil samples with a longer analytical time. PMID:24518341

  17. Mass Spectrometric Analysis for Nuclear Safeguards

    International Nuclear Information System (INIS)

    Boulyga, S.

    2013-01-01

    The release of man-made radionuclides into the environment results in contamination that carries specific isotopic signatures according to the release scenarios and the previous usage of materials and facilities. In order to trace the origin of such contamination and/or to assess the potential impact on the public and environmental health, it is necessary to determine the isotopic composition and activity concentrations of radionuclides in environmental samples in an accurate and timely fashion. Mass spectrometric techniques, such as thermal ionization mass spectrometry (TIMS), secondary ion mass spectrometry (SIMS), and inductively coupled plasma mass spectrometry (ICP-MS) belong to the most powerful methods for analysis of nuclear and related samples in nuclear safeguards, forensics, and environmental monitoring. This presentation will address the potential of mass spectrometric analysis of actinides at ultra-trace concentration levels, isotopic analysis of micro-samples, age determination of nuclear materials as well as identification and quantification of elemental and isotopic signatures of nuclear samples in general. (author)

  18. Gas chromatographic simulated distillation-mass spectrometry for the determination of the boiling point distributions of crude oils

    Science.gov (United States)

    Roussis; Fitzgerald

    2000-04-01

    The coupling of gas chromatographic simulated distillation with mass spectrometry for the determination of the distillation profiles of crude oils is reported. The method provides the boiling point distributions of both weight and volume percent amounts. The weight percent distribution is obtained from the measured total ion current signal. The total ion current signal is converted to weight percent amount by calibration with a reference crude oil of a known distillation profile. Knowledge of the chemical composition of the crude oil across the boiling range permits the determination of the volume percent distribution. The long-term repeatability is equivalent to or better than the short-term repeatability of the currently available American Society for Testing and Materials (ASTM) gas chromatographic method for simulated distillation. Results obtained by the mass spectrometric method are in very good agreement with results obtained by conventional methods of physical distillation. The compositional information supplied by the method can be used to extensively characterize crude oils.

  19. Validation and implementation of liquid chromatographic-mass spectrometric (LC-MS) methods for the quantification of tenofovir prodrugs.

    Science.gov (United States)

    Hummert, Pamela; Parsons, Teresa L; Ensign, Laura M; Hoang, Thuy; Marzinke, Mark A

    2018-04-15

    The nucleotide reverse transcriptase inhibitor tenofovir (TFV) is widely administered in a disoproxil prodrug form (tenofovir disoproxil fumarate, TDF) for HIV management and prevention. Recently, novel prodrugs tenofovir alafenamide fumarate (TAF) and hexadecyloxypropyl tenofovir (CMX157) have been pursued for HIV treatment while minimizing adverse effects associated with systemic TFV exposure. Dynamic and sensitive bioanalytical tools are required to characterize the pharmacokinetics of these prodrugs in systemic circulation. Two parallel methods have been developed, one to combinatorially quantify TAF and TFV, and a second method for CMX157 quantification, in plasma. K 2 EDTA plasma was spiked with TAF and TFV, or CMX157. Following the addition of isotopically labeled internal standards and sample extraction via solid phase extraction (TAF and TFV) or protein precipitation (CMX157), samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis. For TAF and TFV, separation occurred using a Zorbax Eclipse Plus C18 Narrow Bore RR, 2.1 × 50 mm, 3.5 μm column and analytes were detected on an API5000 mass analyzer; CMX157 was separated using a Kinetex C8, 2.1 × 50 mm, 2.6 μm column and quantified using an API4500 mass spectrometer. Methods were validated according to FDA Bioanalytical Method Validation guidelines. Analytical methods: were optimized for the multiplexed monitoring of TAF and TFV, and CMX157 in plasma. The lower limits of quantification (LLOQs) for TAF, TFV, and CMX157 were 0.03, 1.0, and 0.25 ng/mL, respectively. Calibration curves were generated via weighted linear regression of standards. Intra- and inter-assay precision and accuracy studies demonstrated %CVs ≤ 14.4% and %DEVs ≤ ± 7.95%, respectively. Stability and matrix effects studies were also performed. All results were acceptable and in accordance with the recommended guidelines for bioanalytical methods. Assays were also

  20. Separation Techniques for Uranium and Plutonium at Trace Levels for the Thermal Ionization Mass Spectrometric Determination

    International Nuclear Information System (INIS)

    Suh, M. Y.; Han, S. H.; Kim, J. G.; Park, Y. J.; Kim, W. H.

    2005-12-01

    This report describes the state of the art and the progress of the chemical separation and purification techniques required for the thermal ionization mass spectrometric determination of uranium and plutonium in environmental samples at trace or ultratrace levels. Various techniques, such as precipitation, solvent extraction, extraction chromatography, and ion exchange chromatography, for separation of uranium and plutonium were evaluated. Sample preparation methods and dissolution techniques for environmental samples were also discussed. Especially, both extraction chromatographic and anion exchange chromatographic procedures for uranium and plutonium in environmental samples, such as soil, sediment, plant, seawater, urine, and bone ash were reviewed in detail in order to propose some suitable methods for the separation and purification of uranium and plutonium from the safeguards environmental or swipe samples. A survey of the IAEA strengthened safeguards system, the clean room facility of IAEA's NWAL(Network of Analytical Laboratories), and the analytical techniques for safeguards environmental samples was also discussed here

  1. Separation Techniques for Uranium and Plutonium at Trace Levels for the Thermal Ionization Mass Spectrometric Determination

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Han, S. H.; Kim, J. G.; Park, Y. J.; Kim, W. H

    2005-12-15

    This report describes the state of the art and the progress of the chemical separation and purification techniques required for the thermal ionization mass spectrometric determination of uranium and plutonium in environmental samples at trace or ultratrace levels. Various techniques, such as precipitation, solvent extraction, extraction chromatography, and ion exchange chromatography, for separation of uranium and plutonium were evaluated. Sample preparation methods and dissolution techniques for environmental samples were also discussed. Especially, both extraction chromatographic and anion exchange chromatographic procedures for uranium and plutonium in environmental samples, such as soil, sediment, plant, seawater, urine, and bone ash were reviewed in detail in order to propose some suitable methods for the separation and purification of uranium and plutonium from the safeguards environmental or swipe samples. A survey of the IAEA strengthened safeguards system, the clean room facility of IAEA's NWAL(Network of Analytical Laboratories), and the analytical techniques for safeguards environmental samples was also discussed here.

  2. Exploring Blueberry Aroma Complexity by Chromatographic and Direct-Injection Spectrometric Techniques.

    Science.gov (United States)

    Farneti, Brian; Khomenko, Iuliia; Grisenti, Marcella; Ajelli, Matteo; Betta, Emanuela; Algarra, Alberto Alarcon; Cappellin, Luca; Aprea, Eugenio; Gasperi, Flavia; Biasioli, Franco; Giongo, Lara

    2017-01-01

    , and esters that can be used as putative biomarkers to rapidly evaluate the blueberry aroma variations related to ripening and/or senescence as well as to genetic background differences. Moreover, the obtained results demonstrated the complementarity between chromatographic and direct-injection mass spectrometric techniques to study the blueberry aroma.

  3. Gas Chromatography-Mass Spectrometric Analysis and Insecticidal ...

    African Journals Online (AJOL)

    HP

    Original Research Article. Gas Chromatography-Mass Spectrometric Analysis and ... into a natural fumigant/insecticide for the control of stored product insects. Keywords: Mallotus ..... stability as well as reduce cost. ACKNOWLEDGEMENT.

  4. Quantitative analysis of flavonols, flavones, and flavanones in fruits, vegetables and beverages by high-performance liquid chromatography with photo-diode array and mass spectrometric detection

    DEFF Research Database (Denmark)

    Justesen, U.; Knuthsen, Pia; Leth, Torben

    1998-01-01

    after acid hydrolysis of freeze-dried food material. Identification was based on retention time, UV and mass spectra by comparison with commercial standards, and the UV peak areas were used for quantitation of the flavonoid contents. Examples of HPLC-MS analyses of orange pulp, tomato, and apple......A high-performance liquid chromatographic (HPLC) separation method viith photo-diode array (PDA) and mass spectrometric (MS) detection was developed to determine and quantify flavonols, flavones, and flavanones in fruits, vegetables and beverages. The compounds were analysed as aglycones, obtained...

  5. Gas Chromatography-Mass Spectrometric Analysis of Nematicidal ...

    African Journals Online (AJOL)

    Gas Chromatography-Mass Spectrometric Analysis of Nematicidal Essential Oil of Valeriana ... Tropical Journal of Pharmaceutical Research ... have a potential to be developed to natural nematicides for the control of cereal cyst nematodes.

  6. Gas Chromatography-Mass Spectrometric Analysis and Insecticidal ...

    African Journals Online (AJOL)

    Tropical Journal of Pharmaceutical Research ... apelta aerial parts was analyzed by gas chromatography/mass spectrometric (GC/MS) to determine its composition. ... into a natural fumigant/insecticide for the control of stored product insects.

  7. Mass spectrometric detection of radiocarbon for dating applications

    Energy Technology Data Exchange (ETDEWEB)

    Synal, H.-A., E-mail: synal@phys.ethz.ch [ETH Zurich, Laboratory of Ion Beam Physics, Building HPK, 8093 Zurich (Switzerland); Schulze-Koenig, T.; Seiler, M.; Suter, M.; Wacker, L. [ETH Zurich, Laboratory of Ion Beam Physics, Building HPK, 8093 Zurich (Switzerland)

    2013-01-15

    Radiocarbon is still the most important nuclide measured by accelerator mass spectrometry (AMS). The related capabilities for dating and tracer studies are eminent not only in archaeology but also drive important applications in the earth and environmental sciences as well as in biomedical research. So far, standard mass spectrometric systems have not been capable of radiocarbon dating because of interfering molecular isobars which, however, can be completely eliminated in charge changing processes at high ion beam energies (MeV) [1,2]. Here, we present a novel type mass spectrometry system for radiocarbon analyses. Radiocarbon dating was performed using 45 keV {sup 14}C ions from the ion source and a molecule dissociation unit kept at ground potential. This proof-of-principle experiment demonstrates for the first time the feasibility of mass spectrometric radiocarbon dating without an accelerator. The results obtained will be the basis of an optimized design for a radiocarbon dating instrument comparable in size, complexity and cost to standard mass spectrometers.

  8. Mass spectrometric detection of radiocarbon for dating applications

    International Nuclear Information System (INIS)

    Synal, H.-A.; Schulze-König, T.; Seiler, M.; Suter, M.; Wacker, L.

    2013-01-01

    Radiocarbon is still the most important nuclide measured by accelerator mass spectrometry (AMS). The related capabilities for dating and tracer studies are eminent not only in archaeology but also drive important applications in the earth and environmental sciences as well as in biomedical research. So far, standard mass spectrometric systems have not been capable of radiocarbon dating because of interfering molecular isobars which, however, can be completely eliminated in charge changing processes at high ion beam energies (MeV) [1,2]. Here, we present a novel type mass spectrometry system for radiocarbon analyses. Radiocarbon dating was performed using 45 keV 14 C ions from the ion source and a molecule dissociation unit kept at ground potential. This proof-of-principle experiment demonstrates for the first time the feasibility of mass spectrometric radiocarbon dating without an accelerator. The results obtained will be the basis of an optimized design for a radiocarbon dating instrument comparable in size, complexity and cost to standard mass spectrometers.

  9. Mass spectrometric detection of radiocarbon for dating applications

    Science.gov (United States)

    Synal, H.-A.; Schulze-König, T.; Seiler, M.; Suter, M.; Wacker, L.

    2013-01-01

    Radiocarbon is still the most important nuclide measured by accelerator mass spectrometry (AMS). The related capabilities for dating and tracer studies are eminent not only in archaeology but also drive important applications in the earth and environmental sciences as well as in biomedical research. So far, standard mass spectrometric systems have not been capable of radiocarbon dating because of interfering molecular isobars which, however, can be completely eliminated in charge changing processes at high ion beam energies (MeV) [1,2]. Here, we present a novel type mass spectrometry system for radiocarbon analyses. Radiocarbon dating was performed using 45 keV 14C ions from the ion source and a molecule dissociation unit kept at ground potential. This proof-of-principle experiment demonstrates for the first time the feasibility of mass spectrometric radiocarbon dating without an accelerator. The results obtained will be the basis of an optimized design for a radiocarbon dating instrument comparable in size, complexity and cost to standard mass spectrometers.

  10. Identification of volatiles by headspace gas chromatography with simultaneous flame ionization and mass spectrometric detection.

    Science.gov (United States)

    Tiscione, Nicholas B; Yeatman, Dustin Tate; Shan, Xiaoqin; Kahl, Joseph H

    2013-10-01

    Volatiles are frequently abused as inhalants. The methods used for identification are generally nonspecific if analyzed concurrently with ethanol or require an additional analytical procedure that employs mass spectrometry. A previously published technique utilizing a capillary flow technology splitter to simultaneously quantitate and confirm ethyl alcohol by flame ionization and mass spectrometric detection after headspace sampling and gas chromatographic separation was evaluated for the detection of inhalants. Methanol, isopropanol, acetone, acetaldehyde, toluene, methyl ethyl ketone, isoamyl alcohol, isobutyl alcohol, n-butyl alcohol, 1,1-difluoroethane, 1,1,1-trifluoroethane, 1,1,1,2-tetrafluoroethane (Norflurane, HFC-134a), chloroethane, trichlorofluoromethane (Freon®-11), dichlorodifluoromethane (Freon®-12), dichlorofluoromethane (Freon®-21), chlorodifluoromethane (Freon®-22) and 1,2-dichlorotetrafluoroethane (Freon®-114) were validated for qualitative identification by this method. The validation for qualitative identification included evaluation of matrix effects, sensitivity, carryover, specificity, repeatability and ruggedness/robustness.

  11. Characterization of spent nuclear fuels by an online combination of chromatographic and mass spectrometric techniques

    International Nuclear Information System (INIS)

    Guenther-Leopold, Ines; Wernli, Beat; Kopajtic, Zlatko

    2003-01-01

    The determination of the burn-up is one of the essential parts in post-irradiation examinations on nuclear fuel samples. In the frame of national and international research programs the analysis of the isotopic vectors of uranium, plutonium, neodymium and some other fission products and actinides was carried out in the Hot lab of the Paul Scherrer Institute in the last years by using high-performance liquid chromatography coupled online with an inductively coupled plasma quadrupole mass spectrometer. In the meantime a multicollector ICP-MS, suitable for high precision isotope ratio measurements, was installed within the Hot lab and has been used now in combination with a chromatographic separation system for the first time for burn-up determinations of nuclear fuel samples. The results of these investigations, a comparison of both methods with the classical technique for burn-up analyses (thermal ionization mass spectrometry), the advantages and limitations of the methods and the accuracy and precision of this type of analyses are presented in the paper. (author)

  12. Chromatographic, Spectroscopic and Mass Spectrometric Approaches for Exploring the Habitability of Mars in 2012 and Beyond with the Curiosity Rover

    Science.gov (United States)

    Mahaffy, Paul

    2012-01-01

    The Sample Analysis at Mars (SAM) suite of instruments on the Curiosity Rover of Mars Science Laboratory Mission is designed to provide chemical and isotopic analysis of organic and inorganic volatiles for both atmospheric and solid samples. The goals of the science investigation enabled by the gas chromatograph mass spectrometer and tunable laser spectrometer instruments of SAM are to work together with the other MSL investigations is to quantitatively assess habitability through a series of chemical and geological measurements. We describe the multi-column gas chromatograph system employed on SAM and the approach to extraction and analysis of organic compounds that might be preserved in ancient martian rocks.

  13. Exploring Blueberry Aroma Complexity by Chromatographic and Direct-Injection Spectrometric Techniques

    Science.gov (United States)

    Farneti, Brian; Khomenko, Iuliia; Grisenti, Marcella; Ajelli, Matteo; Betta, Emanuela; Algarra, Alberto Alarcon; Cappellin, Luca; Aprea, Eugenio; Gasperi, Flavia; Biasioli, Franco; Giongo, Lara

    2017-01-01

    , for the most aldehydes, alcohols, terpenoids, and esters that can be used as putative biomarkers to rapidly evaluate the blueberry aroma variations related to ripening and/or senescence as well as to genetic background differences. Moreover, the obtained results demonstrated the complementarity between chromatographic and direct-injection mass spectrometric techniques to study the blueberry aroma. PMID:28491071

  14. Exploring Blueberry Aroma Complexity by Chromatographic and Direct-Injection Spectrometric Techniques

    Directory of Open Access Journals (Sweden)

    Brian Farneti

    2017-04-01

    pull of VOCs, for the most aldehydes, alcohols, terpenoids, and esters that can be used as putative biomarkers to rapidly evaluate the blueberry aroma variations related to ripening and/or senescence as well as to genetic background differences. Moreover, the obtained results demonstrated the complementarity between chromatographic and direct-injection mass spectrometric techniques to study the blueberry aroma.

  15. Vitamin D-metabolites from human plasma and mass spectrometric analysis by fast heavy ion induced desorption

    Energy Technology Data Exchange (ETDEWEB)

    Fohlman, J; Peterson, P A [Uppsala Univ. (Sweden). Dept. of Cell Research; Kamensky, I; Hakansson, P; Sundqvist, B [Tandemacceleratorlaboratoriet, Uppsala (Sweden)

    1982-07-01

    D-vitamin metabolites have been isolated from human serum employing chromatographic techniques. The serum carrier protein for vitamin D (DBP) was first isolated by immunosorbent chromatography. Lipid ligands associated with DBP were then extracted with hexane and separated by high pressure liquid chromatography (HPLC). Detection of vitamin D metabolites by their absorbance of ultraviolet light is not sufficiently sensitive to monitor all vitamin D derivatives from a few millilitres of serum. Therefore, further analyses are necessary to quantitative these compounds. We have begun to develop a mass spectrometric method to achieve a reliable, quantitative procedure. As a first step towards this goal a number of pure samples of vitamin D compounds have been studied in a time-of-flight mass spectrometer based on fast heavy ion induced desorption. All vitamin D compounds examined could be detected and identified by their molecular ion and fragment spectra.

  16. Vitamin D-metabolites from human plasma and mass spectrometric analysis by fast heavy ion induced desorption

    International Nuclear Information System (INIS)

    Fohlman, J.; Peterson, P.A.

    1982-01-01

    D-vitamin metabolites have been isolated from human serum employing chromatographic techniques. The serum carrier protein for vitamin D (DBP) was first isolated by immunosorbent chromatography. Lipid ligands associated with DBP were then extracted with hexane and separated by high pressure liquid chromatography (HPLC). Detection of vitamin D metabolites by their absorbance of ultraviolet light is not sufficiently sensitive to monitor all vitamin D derivatives from a few millilitres of serum. Therefore, further analyses are necessary to quantitative these compounds. We have begun to develop a mass spectrometric method to achieve a reliable, quantitative procedure. As a first step towards this goal a number of pure samples of vitamin D compounds have been studied in a time-of-flight mass spectrometer based on fast heavy ion induced desorption. All vitamin D compounds examined could be detected and identified by their molecular ion and fragment spectra. (orig.)

  17. Mass spectrometric researches in isotope cosmochemistry

    International Nuclear Information System (INIS)

    Gopalan, K.

    1979-01-01

    Recent advances in the understanding of solar system processes, past and present, based on mass spectrometric researches on meteorites and moon samples are reviewed. The topics include the following : (1) Duration of nebular condensation, (2) Terminal stages of nucleosynthesis, (3) Planetary formation and evolution, (4) Heterogeneities in the solar nebula and (5) Solar wind composition. (auth.)

  18. Recent Advances in Mass Spectrometry for the Identification of Neuro-chemicals and their Metabolites in Biofluids.

    Science.gov (United States)

    Kailasa, Suresh Kumar; Wu, Hui-Fen

    2013-07-01

    Recently, mass spectrometric related techniques have been widely applied for the identification and quantification of neurochemicals and their metabolites in biofluids. This article presents an overview of mass spectrometric techniques applied in the detection of neurological substances and their metabolites from biological samples. In addition, the advances of chromatographic methods (LC, GC and CE) coupled with mass spectrometric techniques for analysis of neurochemicals in pharmaceutical and biological samples are also discussed.

  19. Advanced hyphenated chromatographic-mass spectrometry in mycotoxin determination: current status and prospects.

    Science.gov (United States)

    Li, Peiwu; Zhang, Zhaowei; Hu, Xiaofeng; Zhang, Qi

    2013-01-01

    Mass spectrometric techniques are essential for advanced research in food safety and environmental monitoring. These fields are important for securing the health of humans and animals, and for ensuring environmental security. Mycotoxins, toxic secondary metabolites of filamentous fungi, are major contaminants of agricultural products, food and feed, biological samples, and the environment as a whole. Mycotoxins can cause cancers, nephritic and hepatic diseases, various hemorrhagic syndromes, and immune and neurological disorders. Mycotoxin-contaminated food and feed can provoke trade conflicts, resulting in massive economic losses. Risk assessment of mycotoxin contamination for humans and animals generally depends on clear identification and reliable quantitation in diversified matrices. Pioneering work on mycotoxin quantitation using mass spectrometry (MS) was performed in the early 1970s. Now, unambiguous confirmation and quantitation of mycotoxins can be readily achieved with a variety hyphenated techniques that combine chromatographic separation with MS, including liquid chromatography (LC) or gas chromatography (GC). With the advent of atmospheric pressure ionization, LC-MS has become a routine technique. Recently, the co-occurrence of multiple mycotoxins in the same sample has drawn an increasing amount of attention. Thus, modern analyses must be able to detect and quantitate multiple mycotoxins in a single run. Improvements in tandem MS techniques have been made to achieve this purpose. This review describes the advanced research that has been done regarding mycotoxin determination using hyphenated chromatographic-MS techniques, but is not a full-circle survey of all the literature published on this topic. The present work provides an overview of the various hyphenated chromatographic-MS-based strategies that have been applied to mycotoxin analysis, with a focus on recent developments. The use of chromatographic-MS to measure levels of mycotoxins, including

  20. Determination of itopride in human plasma by liquid chromatography coupled to tandem mass spectrometric detection: application to a bioequivalence study.

    Science.gov (United States)

    Lee, Heon-Woo; Seo, Ji-Hyung; Choi, Seung-Ki; Lee, Kyung-Tae

    2007-01-30

    A simple method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of itopride in human plasma, using sulpiride as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 359.5>166.1 for itopride and m/z 342.3>111.6 for IS, respectively. Analytes were chromatographed on an YMC C18 reverse-phase chromatographic column by isocratic elution with 1 mM ammonium acetate buffer-methanol (20: 80, v/v; pH 4.0 adjusted with acetic acid). Results were linear (r2=0.9999) over the studied range (0.5-1000 ng mL(-1)) with a total analysis time per run of 2 min for LC-MS/MS. The developed method was validated and successfully applied to bioequivalence studies of itopride hydrochloride in healthy male volunteers.

  1. High performance liquid chromatographic-mass spectrometric assay for the quantitation of BMS-204352 in dog K(3)EDTA plasma.

    Science.gov (United States)

    Yao, Ming; Mantha, Subbarao; Shah, Vinod R; Vachharajani, Nimish N; Arnold, Mark E; Pursley, Janice M; Srinivas, Nuggehally R

    2002-05-01

    A high performance liquid chromatographic-mass spectrometric (LC/MS) assay was developed and validated for the determination of BMS-204352 in dog K(3)EDTA plasma. A 0.5 mL aliquot of control plasma was spiked with BMS-204352 and internal standard (IS) and buffered with 1 mL of 5 mM ammonium acetate. The mixture was then extracted with 3 mL of toluene. After separation and evaporation of the organic phase to dryness using nitrogen at 40 degrees C, the residue was reconstituted in the mobile phase and 25 microL of the sample were injected onto a Hypersil C(18) column (2 x 50 mm; 3 microm) at a flow rate of 0.5 mL/min. The mobile phase was consisted of two solvent mixtures (A and B). Solvent A was composed of 5 mM ammonium acetate and 0.1% triethylamine in 75:25 v/v water:methanol, pH adjusted to 5.5 with glacial acetic acid, and solvent B was 5 mM ammonium acetate in methanol. A linear gradient system was used to elute the analytes. The mass spectrometer was programmed to admit the de-protonated molecules at m/z 352.7 (IS) and m/z 357.9 (BMS-204352). Standard curves of BMS-204352 were linear (r(2) > or = 0.998) over the concentration range of 0.5-1000 ng/mL. The mean predicted quality control (QC) concentrations deviated less than 5.1% from the corresponding nominal values (ie 4, 80, 400 and 2000 ng/mL); the within- and between-assay precision of the assay were within 5.5% relative standard deviation. Stability of BMS-204352 was confirmed after at least three freeze/thaw cycles and BMS-204532 was stable in dog plasma when stored frozen at or below -20 degrees C for at least 16 weeks in spiked QC samples and for at least 4 1/2 weeks for in vivo study samples. BMS-204352 and IS were stable in the injection solvent at room temperature for at least 24 h. The assay was applied to delineate the pharmacokinetic disposition of BMS-204352 in dogs following a single intravenous dose administration. In conclusion, the assay is accurate, precise, specific, sensitive and

  2. [Chromatographic mass spectrometric determination of low-molecular-weight aromatic compounds of microbial origin in the serum from patients with sepsis].

    Science.gov (United States)

    Beloborodova, N V; Arkhipova, A S; Beloborodov, D M; Boĭko, N B; Mel'ko, A I; Olenin, A Iu

    2006-02-01

    The investigation quantitatively determined the content of low-molecular-weight aromatic compounds of microbial origin in the sera of 34 individuals by chromatographic mass spectrometry. An "Agilent Technogies 6890N" gas chromatograph with a 5973 mass selective detector was applied; chromatographic separation of components was effected on an Hp-5MS quartz capillary column. Aromatic small molecules originating from microbes (SMOM) were determined in the sera of 7 patients with sepsis. The diagnosis of sepsis was documented by the presence of the systemic inflammation syndrome and by that of bacteriemia and/or artificial ventilation-associated pneumonia along with the level of procalcitonin of higher than 10 ng/ml. The levels of aromatic SMOM were compared in 10 healthy donors, 8 preoperative cardiosurgical patients, and 9 patients with different abnormalities without sepsis treated in an intensive care unit (ICU). Serum phenylacetic and 3-phenylpropionic acids were found to be prevalent in the healthy donors and postoperative cardiosurgical patients. In ICU patients with different complications without sepsis, more than half the compounds under study were undetectable, the others were found in very low concentrations, which may be accounted for by antibiotic therapy. At the same time, almost the whole spectrum of the test compounds (other than 3-phenylpropionic acid) with the highest concentrations of 3-phenyllactic, p-hydroxyphenylacetic, 3-(p-hydroxyphenyl)lactic and 2-hydroxybutanic acids, was detectable in septic patients receiving a more intensive therapy. The differences were statistically significant (by the Mann-Whitney U-test; p < 0.05). By taking into account the potentially high biological activity of the test compounds, studies are to be continued in this area.

  3. Ion Chromatographic Analyses of Sea Waters, Brines and Related Samples

    Directory of Open Access Journals (Sweden)

    Nataša Gros

    2013-06-01

    Full Text Available This review focuses on the ion chromatographic methods for the analyses of natural waters with high ionic strength. At the beginning a natural diversity in ionic composition of waters is highlighted and terminology clarified. In continuation a brief overview of other review articles of potential interest is given. A review of ion chromatographic methods is organized in four sections. The first section comprises articles focused on the determination of ionic composition of water samples as completely as possible. The sections—Selected Anions, Selected Cations and Metals—follow. The most essential experimental conditions used in different methods are summarized in tables for a rapid comparison. Techniques encountered in the reviewed articles comprise: direct determinations of ions in untreated samples with ion- or ion-exclusion chromatography, or electrostatic ion chromatography; matrix elimination with column-switching; pre-concentration with a chelation ion chromatography and purge-and-trap pre-concentration. Different detection methods were used: non-suppressed conductometric or suppressed conductometric, direct spectrometric or spectrometric after a post-column derivetization, and inductively coupled plasma in combination with optical emission or mass spectrometry.

  4. Determination of 21 trace impurities in UO2 with tributyl phosphate chromatographic separation-USN-inductively coupled/atomic emission spectrometric

    International Nuclear Information System (INIS)

    Hou Lieqi; Wang Shuan; Li Jie

    1996-03-01

    A method of tributyl phosphate chromatographic separation-USN-inductively coupled/atomic emission spectrometric was selected. And the parameters, interference of acid concentrations, interference of coexisting elements, selecting of flow for carrier gas, solution temperature were studied. When the sampling amount is 250 mg, the determination range for Al, Ag, Ba, Ca, Cd, Co, Cr, Cu, Fe, In, Li, Mg, Mn, Mo, Ni, Pb, Sn, Ti, V, Y and Zn are 0.2∼100 ng· -1 , recovery are 94%∼110%. The RSD (n 8) are 0.8%∼6.2%. (3 refs., 4 tabs.)

  5. Mass spectrometric detection of radiocarbon for dating applications

    OpenAIRE

    Synal Hans-Arno

    2013-01-01

    Radiocarbon is still the most important nuclide measured by accelerator mass spectrometry (AMS). The related capabilities for dating and tracer studies are eminent not only in archaeology but also drive important applications in the earth and environmental sciences as well as in biomedical research. So far standard mass spectrometric systems have not been capable of radiocarbon dating because of interfering molecular isobars which however can be completely eliminated in charge changing proces...

  6. Gas chromatography-mass spectrometric determination of traces of ether-type icing inhibitors in free-floating fuels

    Energy Technology Data Exchange (ETDEWEB)

    Shin, H.S. [Dept. of Environmental Education, Kongju National Univ., Kongju (Korea); Abuse Drug Research Center, Kongju National Univ., Kongju (Korea); Ahn, H.S. [Dept. of Environmental Science, Kongju National Univ., Kongju (Korea)

    2004-08-01

    A gas chromatographic-mass spectrometric (GC-MS) assay method has been developed for simultaneous determination of ethylene glycol monomethyl ether (EGME) and diethylene glycol monomethly ether (DEGME) in spilled aviation fuels. Ethylene glycol monobutyl ether (EGBE) and ethylene glycol monoethyl ether (EGEE) were used as internal standard and surrogate, respectively. Sample preparation consisted of back-extraction with 7 mL dichloromethane after extraction of 50 mL of fuel with 2 mL of water. The extract was concentrated to dryness, dissolved in 100 {mu}L methanol, and analyzed by GC-MS with selected-ion monitoring (SIM). The peaks had good chromatographic properties on a semi-polar column. EGME and DEGME were extracted from fuel with high recovery of 75 and 85%, with small variations, respectively. Method detection limits were 1.3 and 1.0 ng mL{sup -1} for EGME and DEGME, respectively, in spilled fuel. DEGME was detected at concentrations of 22.6 and 19.7 ng mL{sup -1} in two samples from among five free-floating samples collected in a tunnel of a subway station located in the vicinity of an army base in Korea. The method might be useful for differentiation between the fuel-types kerosene and JP-8, which might originate from a storage tank. (orig.)

  7. Mirion--a software package for automatic processing of mass spectrometric images.

    Science.gov (United States)

    Paschke, C; Leisner, A; Hester, A; Maass, K; Guenther, S; Bouschen, W; Spengler, B

    2013-08-01

    Mass spectrometric imaging (MSI) techniques are of growing interest for the Life Sciences. In recent years, the development of new instruments employing ion sources that are tailored for spatial scanning allowed the acquisition of large data sets. A subsequent data processing, however, is still a bottleneck in the analytical process, as a manual data interpretation is impossible within a reasonable time frame. The transformation of mass spectrometric data into spatial distribution images of detected compounds turned out to be the most appropriate method to visualize the results of such scans, as humans are able to interpret images faster and easier than plain numbers. Image generation, thus, is a time-consuming and complex yet very efficient task. The free software package "Mirion," presented in this paper, allows the handling and analysis of data sets acquired by mass spectrometry imaging. Mirion can be used for image processing of MSI data obtained from many different sources, as it uses the HUPO-PSI-based standard data format imzML, which is implemented in the proprietary software of most of the mass spectrometer companies. Different graphical representations of the recorded data are available. Furthermore, automatic calculation and overlay of mass spectrometric images promotes direct comparison of different analytes for data evaluation. The program also includes tools for image processing and image analysis.

  8. Thermogravimetric-quadrupole mass-spectrometric analysis of geochemical samples.

    Science.gov (United States)

    Gibson, E. K., Jr.; Johnson, S. M.

    1972-01-01

    Thermogravimetric-quadrupole mass-spectrometric-analysis techniques can be used to study a wide variety of problems involving decomposition processes and identification of released volatile components. A recording vacuum thermoanalyzer has been coupled with a quadrupole mass spectrometer. The rapid scan capabilities of the quadrupole mass spectrometer are used to identify the gaseous components released. The capability of the thermogravimetric-quadrupole mass spectrometer to provide analytical data for identification of the released volatile components, for determination of their sequence of release and for correlation of thermal-decomposition studies is illustrated by an analysis of the Orgueil carbonaceous chondrite.

  9. Quantitative mass-spectrometric analysis of hydrogen helium isotope mixtures

    International Nuclear Information System (INIS)

    Langer, U.

    1998-12-01

    This work deals with the mass-spectrometric method for the quantitative analysis of hydrogen-helium-isotope mixtures, with special attention to fusion plasma diagnostics. The aim was to use the low-resolution mass spectrometry, a standard measuring method which is well established in science and industry. This task is solved by means of the vector mass spectrometry, where a mass spectrum is repeatedly measured, but with stepwise variation of the parameter settings of a quadruple mass spectrometer. In this way, interfering mass spectra can be decomposed and, moreover, it is possible to analyze underestimated mass spectra of complex hydrogen-helium-isotope mixtures. In this work experimental investigations are presented which show that there are different parameters which are suitable for the UMS-method. With an optimal choice of the parameter settings hydrogen-helium-isotope mixtures can be analyzed with an accuracy of 1-3 %. In practice, a low sensitivity for small helium concentration has to be noted. To cope with this task, a method for selective hydrogen pressure reduction has been developed. Experimental investigations and calculations show that small helium amounts (about 1 %) in a hydrogen atmosphere can be analyzed with an accuracy of 3 - 10 %. Finally, this work deals with the effects of the measuring and calibration error on the resulting error in spectrum decomposition. This aspect has been investigated both in general mass-spectrometric gas analysis and in the analysis of hydrogen-helium-mixtures by means of the vector mass spectrometry. (author)

  10. Gas Chromatographic-Mass Spectrometric Analysis of Essential Oil ...

    African Journals Online (AJOL)

    Purpose: To analyze the essential oil composition of the flower of Jasminum officinale L. var. grandifloroum L. (Jasminum grandiflorum) by gas chromatography-mass spectrometry (GC-MS). Methods: The optimum GC-MS conditions used for the analysis were 250 oC inlet temperature, 150 oC MSD detector temperature, ...

  11. Determination of plutonium-241 half-life by mass spectrometric measurement

    International Nuclear Information System (INIS)

    Hiyama, Takashi; Wada, Yukio; Onishi, Koichi

    1982-01-01

    Much data for Pu-241 half-life have been reported, but these values range from 13.8 years to 15.1 years depending on investigators. In order to define the half-life of Pu-241, the half-life was calculated by analyzing the mass spectrometry data obtained in the author's laboratory over the past six years on Plutonium Isotopic Standard Reference Materials prepared at the National Bureau of Standards (NBS). The sample used for this work consisted of SRM-947 and SRM-948 prepared at NBS. Before mass spectrometric analysis, the plutonium aliquot was separated from its Am-241 daughter by anion exchange chromatography, since Am-241 is not distinguished from Pu-241 in the mass spectrometer. 241 Pu/ 239 Pu and 241 Pu/ 240 Pu ratios were calculated from the values of mass spectrometric measurement. From the relation of log N to time, the half-life of Pu-241 was determined, based on the slope using a least squares fit. The half-life of Pu-241 was estimated to be 14.29+-0.15 years. (Yoshitake, I.)

  12. Mass spectrometric investigation of vinyl-substituted organic boron compounds

    International Nuclear Information System (INIS)

    Tarielashvili, V.O.; Ordzhonikidze, K.G.; Parulava, L.P.; Vakhaniya, G.V.

    1992-01-01

    Mass spectrometric investigation of vinyl-substituted organic compounds was conducted. Ionization was performed by electron shock. Possibility of determining boron isotope content is all analyzed organic boron vinyl-substituted compounds by direct method is shown. This simplifies sufficiently and lowers the price of analysis, improves its accuracy and rapidity

  13. Identification and quantification of flavonoids in human urine samples by column switching liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Salka E.; Freese, R.; Cornett, C.

    2000-01-01

    A rapid and sensitive high-performance liquid chromatographic mass spectrometric (HPLC-MS) method is described for the determination and quantification of 12 dietary flavonoid glycosides and aglycons in human urine samples. Chromatographic separation of the analytes of interest was achieved...

  14. Applications of mass spectrometry in the trace element analysis of biological materials

    International Nuclear Information System (INIS)

    Moens, L.

    1997-01-01

    The importance of mass spectrometry for the analysis of biological material is illustrated by reviewing the different mass spectrometric methods applied and describing some typical applications published recently. Though atomic absorption spectrometry is used in the majority of analyses of biological material, most mass spectrometric methods have been used to some extent for trace element determination in biomedical research. The relative importance of the different methods is estimated by reviewing recent research papers. It is striking that especially inductively coupled plasma mass spectrometry is increasingly being applied, partly because the method can be used on-line after chromatographic separation, in speciation studies. Mass spectrometric methods prove to offer unique possibilities in stable isotope tracer studies and for this purpose also experimentally demanding methods such as thermal ionization mass spectrometry and accelerator mass spectrometry are frequently used. (orig.)

  15. Analysis of small carbohydrates in several bioactive botanicals by gas chromatography with mass spectrometry and liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Moldoveanu, Serban; Scott, Wayne; Zhu, Jeff

    2015-11-01

    Bioactive botanicals contain natural compounds with specific biological activity, such as antibacterial, antioxidant, immune stimulating, and taste improving. A full characterization of the chemical composition of these botanicals is frequently necessary. A study of small carbohydrates from the plant materials of 18 bioactive botanicals is further described. The study presents the identification of the carbohydrate using a gas chromatographic-mass spectrometric analysis that allows detection of molecules as large as maltotetraose, after changing them into trimethylsilyl derivatives. A number of carbohydrates in the plant (fructose, glucose, mannose, sucrose, maltose, xylose, sorbitol, and myo-, chiro-, and scyllo-inositols) were quantitated using a novel liquid chromatography with tandem mass spectrometric technique. Both techniques involved new method developments. The gas chromatography with mass spectrometric analysis involved derivatization and separation on a Rxi(®)-5Sil MS column with H2 as a carrier gas. The liquid chromatographic separation was obtained using a hydrophilic interaction type column, YMC-PAC Polyamine II. The tandem mass spectrometer used an electrospray ionization source in multiple reaction monitoring positive ion mode with the detection of the adducts of the carbohydrates with Cs(+) ions. The validated quantitative procedure showed excellent precision and accuracy allowing the analysis in a wide range of concentrations of the analytes. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Mass Spectrometric Characteristics of Prenylated Indole Derivatives from Marine-Derived Penicillium sp. NH-SL.

    Science.gov (United States)

    Ding, Hui; Ding, Wanjing; Ma, Zhongjun

    2017-03-22

    Two prenylated indole alkaloids were isolated from the ethyl acetate extracts of a marine-derived fungus Penicillium sp. NH-SL and one of them exhibited potent cytotoxic activity against mouse hepa 1c1c7 cells. In order to detect other bioactive analogs, we used liquid chromatogram tandem mass spectrometry (LC-MS/MS) to analyze the mass spectrometric characteristics of the isolated compounds as well as the crude extracts. As a result, three other analogs were detected, and their structures were deduced according to the similar fragmentation patterns. This is the first systematic report on the mass spectrometric characteristics of prenylated indole derivatives.

  17. Electrospray Ionization Mass Spectrometric Analysis of Highly Reactive Glycosyl Halides

    Directory of Open Access Journals (Sweden)

    Lajos Kovács

    2012-07-01

    Full Text Available Highly reactive glycosyl chlorides and bromides have been analysed by a routine mass spectrometric method using electrospray ionization and lithium salt adduct-forming agents in anhydrous acetonitrile solution, providing salient lithiated molecular ions [M+Li]+, [2M+Li]+ etc. The role of other adduct-forming salts has also been evaluated. The lithium salt method is useful for accurate mass determination of these highly sensitive compounds.

  18. Impact of solvent conditions on separation and detection of basic drugs by micro liquid chromatography-mass spectrometry under overloading conditions.

    Science.gov (United States)

    Schubert, Birthe; Oberacher, Herbert

    2011-06-03

    In this study the impact of solvent conditions on the performance of μLC/MS for the analysis of basic drugs was investigated. Our aim was to find experimental conditions that enable high-performance chromatographic separation particularly at overloading conditions paired with a minimal loss of mass spectrometric detection sensitivity. A focus was put on the evaluation of the usability of different kinds of acidic modifiers (acetic acid (HOAc), formic acid (FA), methansulfonic acid (CH₃SO₃H), trifluoroacetic acid (TFA), pentafluoropropionic acid (PFPA), and heptafluorobutyric acid (HFBA)). The test mixture consisted of eleven compounds (bunitrolol, caffeine, cocaine, codeine, diazepam, doxepin, haloperidol, 3,4-methylendioxyamphetamine, morphine, nicotine, and zolpidem). Best chromatographic performance was obtained with the perfluorinated acids. Particularly, 0.010-0.050% HFBA (v/v) was found to represent a good compromise in terms of chromatographic performance and mass spectrometric detection sensitivity. Compared to HOAc, on average a 50% reduction of the peak widths was observed. The use of HFBA was particularly advantageous for polar compounds such as nicotine; only with such a hydrophobic ion-pairing reagent chromatographic retention of nicotine was observed. Best mass spectrometric performance was obtained with HOAc and FA. Loss of detection sensitivity induced by HFBA, however, was moderate and ranged from 0 to 40%, which clearly demonstrates that improved chromatographic performance is able to compensate to a large extent the negative effect of reduced ionization efficiency on detection sensitivity. Applications of μLC/MS for the qualitative and quantitative analysis of clinical and forensic toxicological samples are presented. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Importance of optimizing chromatographic conditions and mass spectrometric parameters for supercritical fluid chromatography/mass spectrometry.

    Science.gov (United States)

    Fujito, Yuka; Hayakawa, Yoshihiro; Izumi, Yoshihiro; Bamba, Takeshi

    2017-07-28

    Supercritical fluid chromatography/mass spectrometry (SFC/MS) has great potential in high-throughput and the simultaneous analysis of a wide variety of compounds, and it has been widely used in recent years. The use of MS for detection provides the advantages of high sensitivity and high selectivity. However, the sensitivity of MS detection depends on the chromatographic conditions and MS parameters. Thus, optimization of MS parameters corresponding to the SFC condition is mandatory for maximizing performance when connecting SFC to MS. The aim of this study was to reveal a way to decide the optimum composition of the mobile phase and the flow rate of the make-up solvent for MS detection in a wide range of compounds. Additionally, we also showed the basic concept for determination of the optimum values of the MS parameters focusing on the MS detection sensitivity in SFC/MS analysis. To verify the versatility of these findings, a total of 441 pesticides with a wide polarity range (logP ow from -4.21 to 7.70) and pKa (acidic, neutral and basic). In this study, a new SFC-MS interface was used, which can transfer the entire volume of eluate into the MS by directly coupling the SFC with the MS. This enabled us to compare the sensitivity or optimum MS parameters for MS detection between LC/MS and SFC/MS for the same sample volume introduced into the MS. As a result, it was found that the optimum values of some MS parameters were completely different from those of LC/MS, and that SFC/MS-specific optimization of the analytical conditions is required. Lastly, we evaluated the sensitivity of SFC/MS using fully optimized analytical conditions. As a result, we confirmed that SFC/MS showed much higher sensitivity than LC/MS when the analytical conditions were fully optimized for SFC/MS; and the high sensitivity also increase the number of the compounds that can be detected with good repeatability in real sample analysis. This result indicates that SFC/MS has potential for

  20. The measurement of mass spectrometric peak height ratio of helium isotope in trace samples

    International Nuclear Information System (INIS)

    Sun Mingliang

    1989-01-01

    An experiment study on the measurement of mass spectrometric peak height ratio of helium isotope in the trace gaseous sample is discussed by using the gas purification line designed by the authors and model VG-5400 static-vacuum noble gas mass spectrometer imported and air helium as a standard. The results show that the amount of He and Ne in natural gas sample is 99% after purification. When the amount of He in Mass Spectrometer is more than 4 x 10 -7 cm 3 STP, it's sensitivity remains stable, about 10 -4 A/cm 3 STP He and the precision of 3 He/ 4 He ratio within the following 17 days is 1.32%. The 'ABA' pattern and experiment condition in the measurement of mass spectrometric peak height ratio of He isotope are presented

  1. Neutron activation and mass spectrometric measurement of /sup 129/I

    International Nuclear Information System (INIS)

    Strebin, R.S. Jr.; Brauer, F.P.; Kaye, J.H.; Rapids, M.S.; Stoffels, J.J.

    1987-11-01

    An integrated procedure has been developed for measurement of /sup 129/I by neutron activation analysis and mass spectrometry. An iodine isolation procedure previously used for neutron activation has been modified to provide separated iodine suitable for mass spectrometric measurement as well. Agreement between both methods has been achieved within error limits. The measurement limit by each method is about 10/sup 7/ atoms (2 fg) of /sup 129/I. 13 refs,. 4 figs., 1 tab

  2. New FORTRAN computer programs to acquire and process isotopic mass-spectrometric data

    International Nuclear Information System (INIS)

    Smith, D.H.

    1982-08-01

    The computer programs described in New Computer Programs to Acquire and Process Isotopic Mass Spectrometric Data have been revised. This report describes in some detail the operation of these programs, which acquire and process isotopic mass spectrometric data. Both functional and overall design aspects are addressed. The three basic program units - file manipulation, data acquisition, and data processing - are discussed in turn. Step-by-step instructions are included where appropriate, and each subsection is described in enough detail to give a clear picture of its function. Organization of file structure, which is central to the entire concept, is extensively discussed with the help of numerous tables. Appendices contain flow charts and outline file structure to help a programmer unfamiliar with the programs to alter them with a minimum of lost time

  3. Gas chromatographic-mass spectrometric analysis of di(2-ethylhexyl) phthalate and its metabolites in hepatic microsomal incubations

    Energy Technology Data Exchange (ETDEWEB)

    Pietrogrande, M.C.; Rossi, D.; Paganetto, G

    2003-03-17

    A method is reported for the determination of di(2-ethylhexyl) phthalate (DEHP) and its metabolites in in vitro metabolism studies. Gas chromatography-mass spectrometry (GC-MS) analysis allows separation of 18 by-products of DEHP metabolism. On the basis of retention time and specific mass spectra m/z values, three classes of compounds can be identified: (i) alcohols as hydrolysis product; (ii) acids produced by alcohol oxidation; (iii) compounds retaining phthalic moiety. The chromatogram can also be acquired in SIM mode at m/z 149 resulting in 13 well-separated chromatographic peaks: from retention time and mass spectra it can be inferred that the main peaks correspond to mono(2-ethylhexyl) phthalate (MEHP) and ({omega}-1)-hydroxyl-MEHP. The kinetics of DEHP metabolism was studied using an S9 Aroclor-induced liver fraction as in vitro model and following incubation assay after 20, 40, 60 and 90 min. The composition of incubation mixtures can be quantitatively evaluated from selected ion monitoring chromatograms at m/z 149: the by-product concentration increases during the incubation time, as a consequence of DEHP degradation. During the incubation test a significant conversion of DEHP into MEHP is observed: a conversion yield of 10, 13, 16 and 20% of the original DEHP is obtained after 20, 40, 60 and 90 min, respectively. The metabolic conversion of DEHP to MEHP explains the endocrine-disrupting activity of the original DEHP; moreover, it has been demonstrated that MEHP and its ({omega}-1)-oxidation metabolite induce peroxisome proliferation. This result strengthens the suggestion that the study of DEHP metabolic pathway is fundamental to better understanding its toxicological behavior.

  4. Mass spectrometric detection of siRNA in plasma samples for doping control purposes.

    Science.gov (United States)

    Kohler, Maxie; Thomas, Andreas; Walpurgis, Katja; Schänzer, Wilhelm; Thevis, Mario

    2010-10-01

    Small interfering ribonucleic acid (siRNA) molecules can effect the expression of any gene by inducing the degradation of mRNA. Therefore, these molecules can be of interest for illicit performance enhancement in sports by affecting different metabolic pathways. An example of an efficient performance-enhancing gene knockdown is the myostatin gene that regulates muscle growth. This study was carried out to provide a tool for the mass spectrometric detection of modified and unmodified siRNA from plasma samples. The oligonucleotides are purified by centrifugal filtration and the use of an miRNA purification kit, followed by flow-injection analysis using an Exactive mass spectrometer to yield the accurate masses of the sense and antisense strands. Although chromatography and sensitive mass spectrometric analysis of oligonucleotides are still challenging, a method was developed and validated that has adequate sensitivity (limit of detection 0.25-1 nmol mL(-1)) and performance (precision 11-21%, recovery 23-67%) for typical antisense oligonucleotides currently used in clinical studies.

  5. Mass spectrometric methods for trace analysis of metals

    International Nuclear Information System (INIS)

    Bahr, U.; Schulten, H.R.

    1981-01-01

    A brief outline is given of the principles of mass spectrometry (MS) and the fundamentals of qualitative and quantitative mass spectrometric analysis emphasizing recent developments and results. Classical methods of the analysis of solids, i.e. spark-source MS and thermal ionization MS, as well as recent methods of metal analysis are described. Focal points in this survey of recently developed techniques include secondary ion MS, laser probe MS, plasma ion source MS, gas discharge MS and field desorption MS. Here, a more detailed description is given and the merits of these emerging methods are discussed more explicitly. In particular, the results of the field desorption techniques in elemental analyses are reviewed and critically evaluated

  6. Mass-spectrometric investigation of rare earth acetylacetonates dipivaloylmethanates and their adducts

    International Nuclear Information System (INIS)

    Gavrishzhuk, E.M.; Dzyubenko, N.G.; Martynenko, L.I.

    1985-01-01

    Peculiarities of fragmentation of molecular ions of rare earth acetylacetonates and dipivaloylmethanates under mass-spectrometric investigation of these compounds as well as their adducts with o-phenanthroline, α,α'-dipyridyl, triphenylphosphine oxide are considered in the given review. Similar data for identical derivants of some transitions metals are presented. Data on potentials of appearance and dissociation energy of basic ions in mass-spectra of the studied β-diketonates are analyzed

  7. Gas chromatography interfaced with atmospheric pressure ionization-quadrupole time-of-flight-mass spectrometry by low-temperature plasma ionization

    DEFF Research Database (Denmark)

    Norgaard, Asger W.; Kofoed-Sorensen, Vivi; Svensmark, Bo

    2013-01-01

    A low temperature plasma (LTP) ionization interface between a gas chromatograph (GC) and an atmospheric pressure inlet mass spectrometer, was constructed. This enabled time-of-flight mass spectrometric detection of GC-eluting compounds. The performance of the setup was evaluated by injection...

  8. Non-Destructive X-ray Spectrometric and Chromatographic Analysis of Metal Containers and Their Contents, from Ancient Macedonia

    Directory of Open Access Journals (Sweden)

    Christos S. Katsifas

    2018-06-01

    Full Text Available This work describes a holistic archaeometric approach to ancient Macedonian specimens. In the region of the ancient city Lete, the deceased members of a rich and important family were interred in a cluster of seven tombs (4th century BC. Among the numerous grave goods, there was also a set of metal containers preserving their original content. The physico-chemical analysis of the containers and their contents was performed in order to understand the purpose of their use. For the containers, Energy Dispersive micro-X-Ray Fluorescence (EDμXRF spectroscopy was implemented taking advantage of its non-invasive character. The case (B35 and the small pyxis (B37 were made of a binary Cu-Sn alloy accompanied by a slight amount of impurities (Fe, Pb, As and the two miniature bowls were made of almost pure Cu. For the study of the contents, a combination of EDμXRF, X-Ray Diffraction (XRD, and Gas Chromatography—Mass Spectrometry (GC-MS was carried out. Especially for the extraction of the volatile compounds, the Solid Phase Micro-Extraction (SPME technique was used in the headspace mode. Because of the detection of Br, High Pressure Liquid Chromatography coupled to a Diode-Array-Detector (HPLC-DAD was implemented, confirming the existence of the ancient dye shellfish purple (porphyra in Greek. The analytical results of the combined implementation of spectrometric and chromatographic analytical techniques of the metal containers and their contents expand our knowledge about the pharmaceutical practices in Macedonia during the 4th century BC.

  9. Dual quantification of dapivirine and maraviroc in cervicovaginal secretions from ophthalmic tear strips and polyester-based swabs via liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis.

    Science.gov (United States)

    Parsons, Teresa L; Emory, Joshua F; Seserko, Lauren A; Aung, Wutyi S; Marzinke, Mark A

    2014-09-01

    Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50mm×2.1mm, 1.7μm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05-25ng/tear strip, and 0.025-25ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25-125ng/swab for dapivirine and 0.125-125ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000ng/tear strip and 11,250ng/swab. Standard curves were generated via weighted (1/x(2)) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. A rugged LC-MS/MS method for the dual quantification of dapivirine and

  10. Mass spectrometric investigation of fluorated europium β-diketonates

    International Nuclear Information System (INIS)

    Khomenko, V.S.; Lozinskij, M.O.; Fialkov, Yu.A.; Rasshinina, T.A.; Suboch, V.P.; AN Ukrainskoj SSR, Kiev. Inst. Organicheskoj Khimii)

    1983-01-01

    Ternary complexes of europium with two organic lidands - fluorated β-diketone and organic base - in the aqueous phase at electron shock are investigated; regroupings that take place in them are established. Mass-spectrometric investigation has shown that complexes with β-diketones, containing in oxygen atom in a fluorated radical, eliminate stable molecules of difluorophosgen, CoF 2 . For the complexes studied under the above conditions the Co molecule elimination is also typical which is accompanied by the formation of ions with a metal-carbon bond

  11. A novel reversed-phase HPLC method for the determination of urinary creatinine by pre-column derivatization with ethyl chloroformate: comparative studies with the standard Jaffé and isotope-dilution mass spectrometric assays.

    Science.gov (United States)

    Leung, Elvis M K; Chan, Wan

    2014-02-01

    Creatinine is an important biomarker for renal function diagnosis and normalizing variations in urinary drug/metabolites concentration. Quantification of creatinine in biological fluids such as urine and plasma is important for clinical diagnosis as well as in biomonitoring programs and urinary metabolomics/metabonomics research. Current methods for creatinine determination either are nonselective or involve the use of expensive mass spectrometers. In this paper, a novel reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of creatinine of high hydrophilicity by pre-column derivatization with ethyl chloroformate is presented. N-Ethyloxycarbonylation of creatinine significantly enhanced the hydrophobicity of creatinine, facilitating its chromatographic retention as well as quantification by HPLC. Factors governing the derivatization reaction were studied and optimized. The developed method was validated and applied for the determination of creatinine in rat urine samples. Comparative studies with isotope-dilution mass spectrometric method revealed that the two methods do not yield systematic differences in creatinine concentrations, indicating the HPLC method is suitable for the determination of creatinine in urine samples.

  12. Mass spectrometric study of Nd2S3 vaporization

    International Nuclear Information System (INIS)

    Fenochka, B.V.

    1987-01-01

    The authors conduct a mass-spectrometric study of neodymium(III) sulfide vaporization. The chemical composition of the samples was stoichiometric and the samples were vaporized from tantalum effusion cells. When the vapor over Nd 2 S 3 is ionized by electrons the mass spectra shows monovalent cations of Nd, S, NdS, and NdO. The enthalpy of vaporization if Nd atoms from Nd 2 S 3 at average experimental temperatures and the standard enthalpy of reaction is shown. Also presented is the enthalpy of vaporization of NdS molecules from Nd 2 S 3 at average experimental temperatures and the standard enthalpy of reaction

  13. Quantitative Mass Spectrometric Analysis of Ropivacaine and Bupivacaine in Authentic, Pharmaceutical and Spiked Human Plasma without Chromatographic Separation

    Directory of Open Access Journals (Sweden)

    Nahla N. Salama

    2009-01-01

    Full Text Available The present study employs time of flight mass spectrometry for quantitative analysis of the local anesthetic drugs ropivacaine and bupivacaine in authentic, pharmaceutical and spiked human plasma as well as in the presence of their impurities 2,6-dimethylaniline and alkaline degradation product. The method is based on time of flight electron spray ionization mass spectrometry technique without preliminary chromatographic separation and makes use of bupivacaine as internal standard for ropivacaine, which is used as internal standard for bupivacaine. A linear relationship between drug concentrations and the peak intensity ratio of ions of the analyzed substances is established. The method is linear from 23.8 to 2380.0 ng mL −1 for both drugs. The correlation coefficient was ≥0.996 in authentic and spiked human plasma. The average percentage recoveries in the ranges of 95.39%-102.75% was obtained. The method is accurate (% RE <; 5% and reproducible with intra- and inter-assay precision (RSD% <; 8.0%. The quantification limit is 23.8 ng mL −1 for both drugs. The method is not only highly sensitive and selective, but also simple and effective for determination or identification of both drugs in authentic and biological fluids. The method can be applied in purity testing, quality control and stability monitoring for the studied drugs.

  14. Quantitative Mass spectrometric Analysis of Ropivacaine and Bupivacaine in Authentic, Pharmaceutical and Spiked Human Plasma without Chromatographic Separation

    Directory of Open Access Journals (Sweden)

    Nahla N. Salama

    2009-01-01

    Full Text Available The present study employs time of flight mass spectrometry for quantitative analysis of the local anesthetic drugs ropivacaine and bupivacaine in authentic, pharmaceutical and spiked human plasma as well as in the presence of their impurities 2,6-dimethylaniline and alkaline degradation product. The method is based on time of flight electron spray ionization mass spectrometry technique without preliminary chromatographic separation and makes use of bupivacaine as internal standard for ropivacaine, which is used as internal standard for bupivacaine. A linear relationship between drug concentrations and the peak intensity ratio of ions of the analyzed substances is established. The method is linear from 23.8 to 2380.0 ng mL-1 for both drugs. The correlation coefficient was ≥0.996 in authentic and spiked human plasma. The average percentage recoveries in the ranges of 95.39%–102.75% was obtained. The method is accurate (% RE < 5% and reproducible with intra- and inter-assay precision (RSD% < 8.0%. The quantification limit is 23.8 ng mL-1 for both drugs. The method is not only highly sensitive and selective, but also simple and effective for determination or identification of both drugs in authentic and biological fluids. The method can be applied in purity testing, quality control and stability monitoring for the studied drugs.

  15. The interlaboratory experiment IDA-72 on mass spectrometric isotope dilution analysis. Vol. 2

    International Nuclear Information System (INIS)

    Beyrich, W.; Drosselmeyer, E.

    1975-07-01

    Volume II of the report on the IDA-72 experiment contains papers written by different authors on a number of special topics connected with the preparation, performance and evaluation of the interlaboratory test. In detail the sampling procedures for active samples of the reprocessing plant and the preparation of inactive reference and spike solution from standard material are described as well as new methods of sample conditioning by evaporation. An extra chapter is devoted to the chemical sample treatment as a preparation for mass spectrometric analysis of the U and Pu content of the solutions. Special topics are also methods for mass discrimination corrections, α-spectrometer measurements as a supplement for the determination of Pu-238 and the comparison of concentration determinations by mass spectrometric isotope dilution analysis with those performed by X-ray fluorescence spectrometry. The last part of this volume contains papers connected with the computerized statistical evaluation of the high number of data. (orig.) [de

  16. Mass spectrometric identification of isocyanate-induced modifications of keratins in human skin

    NARCIS (Netherlands)

    Hulst, A.G.; Verstappen, D.R.W.; Riet-van Oeveren, D. van der; Vermeulen, N.P.E.; Noort, D.

    2015-01-01

    In the current paper we show that exposure of human callus to isocyanates leads to covalent modifications within keratin proteins. Mass spectrometric analyses of pronase digests of keratin isolated from exposed callus show that both mono- and di-adducts (for di-isocyanates) are predominantly formed

  17. Quantitative mass spectrometry of unconventional human biological matrices

    Science.gov (United States)

    Dutkiewicz, Ewelina P.; Urban, Pawel L.

    2016-10-01

    The development of sensitive and versatile mass spectrometric methodology has fuelled interest in the analysis of metabolites and drugs in unconventional biological specimens. Here, we discuss the analysis of eight human matrices-hair, nail, breath, saliva, tears, meibum, nasal mucus and skin excretions (including sweat)-by mass spectrometry (MS). The use of such specimens brings a number of advantages, the most important being non-invasive sampling, the limited risk of adulteration and the ability to obtain information that complements blood and urine tests. The most often studied matrices are hair, breath and saliva. This review primarily focuses on endogenous (e.g. potential biomarkers, hormones) and exogenous (e.g. drugs, environmental contaminants) small molecules. The majority of analytical methods used chromatographic separation prior to MS; however, such a hyphenated methodology greatly limits analytical throughput. On the other hand, the mass spectrometric methods that exclude chromatographic separation are fast but suffer from matrix interferences. To enable development of quantitative assays for unconventional matrices, it is desirable to standardize the protocols for the analysis of each specimen and create appropriate certified reference materials. Overcoming these challenges will make analysis of unconventional human biological matrices more common in a clinical setting. This article is part of the themed issue 'Quantitative mass spectrometry'.

  18. Mass spectrometric identification of isoforms of PR proteins in xylem sap of fungus-infected tomato

    NARCIS (Netherlands)

    Rep, Martijn; Dekker, Henk L.; Vossen, Jack H.; de Boer, Albert D.; Houterman, Petra M.; Speijer, Dave; Back, Jaap W.; de Koster, Chris G.; Cornelissen, Ben J. C.

    2002-01-01

    The protein content of tomato (Lycopersicon esculentum) xylem sap was found to change dramatically upon infection with the vascular wilt fungus Fusarium oxysporum. Peptide mass fingerprinting and mass spectrometric sequencing were used to identify the most abundant proteins appearing during

  19. Spectrometric techniques 4

    CERN Document Server

    Vanasse, George A

    2013-01-01

    Spectrometric Techniques, Volume IV discusses three widely diversified areas of spectrometric techniques. The book focuses on three spectrometric methods. Chapter 1 discusses the phenomenology and applications of Coherent Anti-Stokes Raman Spectroscopy (CARS), the most commonly used optical technique that exploit the Raman effect. The second chapter is concerned with diffraction gratings and mountings for the Vacuum Ultraviolet Spectral Region. Chapter 3 accounts the uses of mass spectrometry, detectors, types of spectrometers, and ion sources. Physicists and chemists will find the book a go

  20. Challenges and recent advances in mass spectrometric imaging of neurotransmitters

    Science.gov (United States)

    Gemperline, Erin; Chen, Bingming; Li, Lingjun

    2014-01-01

    Mass spectrometric imaging (MSI) is a powerful tool that grants the ability to investigate a broad mass range of molecules, from small molecules to large proteins, by creating detailed distribution maps of selected compounds. To date, MSI has demonstrated its versatility in the study of neurotransmitters and neuropeptides of different classes toward investigation of neurobiological functions and diseases. These studies have provided significant insight in neurobiology over the years and current technical advances are facilitating further improvements in this field. neurotransmitters, focusing specifically on the challenges and recent Herein, we advances of MSI of neurotransmitters. PMID:24568355

  1. Separation of silver ions and starch modified silver nanoparticles using high performance liquid chromatography with ultraviolet and inductively coupled mass spectrometric detection

    International Nuclear Information System (INIS)

    Hanley, Traci A.; Saadawi, Ryan; Zhang, Peng; Caruso, Joseph A.; Landero-Figueroa, Julio

    2014-01-01

    The production of commercially available products marketed to contain silver nanoparticles is rapidly increasing. Species-specific toxicity is a phenomenon associated with many elements, including silver, making it imperative to develop a method to identify and quantify the various forms of silver (namely, silver ions vs. silver nanoparticles) possibly present in these products. In this study a method was developed using high performance liquid chromatography (HPLC) with ultraviolet (UV–VIS) and inductively coupled mass spectrometric (ICP-MS) detection to separate starch stabilized silver nanoparticles (AgNPs) and silver ions (Ag + ) by cation exchange chromatography with 0.5 M nitric acid mobile phase. The silver nanoparticles and ions were baseline resolved with an ICP-MS response linear over four orders of magnitude, 0.04 mg kg −1 detection limit, and 90% chromatographic recovery for silver solutions containing ions and starch stabilized silver nanoparticles smaller than 100 nm

  2. Separation of silver ions and starch modified silver nanoparticles using high performance liquid chromatography with ultraviolet and inductively coupled mass spectrometric detection

    Energy Technology Data Exchange (ETDEWEB)

    Hanley, Traci A.; Saadawi, Ryan; Zhang, Peng; Caruso, Joseph A., E-mail: joseph.caruso@uc.edu; Landero-Figueroa, Julio

    2014-10-01

    The production of commercially available products marketed to contain silver nanoparticles is rapidly increasing. Species-specific toxicity is a phenomenon associated with many elements, including silver, making it imperative to develop a method to identify and quantify the various forms of silver (namely, silver ions vs. silver nanoparticles) possibly present in these products. In this study a method was developed using high performance liquid chromatography (HPLC) with ultraviolet (UV–VIS) and inductively coupled mass spectrometric (ICP-MS) detection to separate starch stabilized silver nanoparticles (AgNPs) and silver ions (Ag{sup +}) by cation exchange chromatography with 0.5 M nitric acid mobile phase. The silver nanoparticles and ions were baseline resolved with an ICP-MS response linear over four orders of magnitude, 0.04 mg kg{sup −1} detection limit, and 90% chromatographic recovery for silver solutions containing ions and starch stabilized silver nanoparticles smaller than 100 nm.

  3. Mass spectrometric investigation of fluorated europium. beta. -diketonates. [Electrons

    Energy Technology Data Exchange (ETDEWEB)

    Khomenko, V.S.; Lozinskij, M.O.; Fialkov, Yu.A.; Rasshinina, T.A.; Suboch, V.P. (AN Belorusskoj SSR, Minsk. Inst. Fiziki; AN Ukrainskoj SSR, Kiev. Inst. Organicheskoj Khimii)

    Ternary complexes of europium with two organic ligands - fluorated ..beta..-diketone and organic base - in the aqueous phase at electron shock are investigated; regroupings that take place in them are established. Mass-spectrometric investigation has shown that complexes with ..beta..-diketones, containing in oxygen atom in a fluorated radical, eliminate stable molecules of difluorophosgen, CoF/sub 2/. For the complexes studied under the above conditions the Co molecule elimination is also typical which is accompanied by the formation of ions with a metal-carbon bond.

  4. Standard test methods for chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade boron carbide

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 These test methods cover procedures for the chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade boron carbide powder and pellets to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Total Carbon by Combustion and Gravimetry 7-17 Total Boron by Titrimetry 18-28 Isotopic Composition by Mass Spectrometry 29-38 Chloride and Fluoride Separation by Pyrohydrolysis 39-45 Chloride by Constant-Current Coulometry 46-54 Fluoride by Ion-Selective Electrode 55-63 Water by Constant-Voltage Coulometry 64-72 Impurities by Spectrochemical Analysis 73-81 Soluble Boron by Titrimetry 82-95 Soluble Carbon by a Manometric Measurement 96-105 Metallic Impurities by a Direct Reader Spectrometric Method 106-114

  5. Speciation of eight arsenic compounds in human urine by high performance liquid chromatography with inductively coupled plasma mass spectrometric detection using antimonate for internal chromatographic standardization

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt; Pritzl, G.; Hansen, S. H.

    1993-01-01

    Four anionic and four cationic arsenic compounds in urine were separated by anion- and cation-exchange high-performance liquid chromatography and detected by inductively coupled plasma mass spectrometry (ICP-MS) at m/z 75. The species were the anions arsenite, arsenate, monomethylarsonate...... and dimethylarsinate and the cations arsenobetaine, trimethylarsine oxide, arsenocholine and the tetramethylarsonium ion. Hexahydroxyantimonate(III) was co-chromatographed with the arsenic anions but detected at m/z 121 and used as an internal standard for their qualitative analysis. Arsenite was prone to oxidation....... The argon chloride interference at m/z 75 was eliminated by chromatographic separation of the chloride present in the sample from the arsenic analytes. The ClO+ ion detected at m/z 51 and 53 was used to monitor the retention time of chloride in the anion-exchange system. The chloride eluted about 100 s...

  6. Comparison of radioimmunoassay and gas chromatographic mass spectrometric assay for d-amphetamine

    International Nuclear Information System (INIS)

    Powers, K.H.; Ebert, M.H.

    1979-01-01

    Quantification of low levels of psychotropic drugs (10 -7 to 10 -9 g ml -1 ) in small volumes of plasma requires sensitive and accurate methods. Validation of these methods is best achieved by comparing results obtained using several techniques. In this study, amphetamine levels in plasma were measured using gas chromatography mass spectrometry and radioimmunoassay. Correlation of the results obtained by the two methods was found to be positive and high (R = 0.9822). The average coefficient of variation between assays for gas chromatography mass spectrometry was 5.8% and for radioimmunoassay was 12.3%, while the average coefficient of variation within assays for gas chromatography mass spectrometry was 4.9% and for radioimmunoassay 6.9%. Although gas chromatography mass spectrometry was 1.9 times more sensitive than radioimmunoassay, for most purposes, the convenience of the radioimmunoassay method outweighs the technical superiority of gas chromatography mass spectrometry. (author)

  7. Analysis of 2-methylthio-derivatives of isoprenoid cytokinins by liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tarkowski, Petr, E-mail: petr.tarkowski@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Vaclavikova, Katerina, E-mail: katka.vaclavik@seznam.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Novak, Ondrej, E-mail: ondrej.novak@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Pertry, Ine, E-mail: ine.pertry@ugent.BE [Department of Plant Biotechnology and Genetics, Ghent University, K.L.Ledeganckstraat 35, B-9000 Gent (Belgium); Hanus, Jan, E-mail: helehan@seznam.cz [Isotope Laboratory, Institute of Experimental Botany ASCR, Videnska 1083, 142 20 Prague (Czech Republic); Whenham, Robert [Apex Organics, Devon, England (United Kingdom); Vereecke, Danny, E-mail: danny.vereecke@hogent.BE [Department of Plant Production, University College Ghent, Ghent University, Schoonmeersstraat 52, B-9000 Gent (Belgium); Sebela, Marek, E-mail: marek.sebela@upol.cz [Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Strnad, Miroslav, E-mail: miroslav.strnad@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic)

    2010-11-08

    A sensitive and reliable high-performance liquid chromatographic method with tandem mass spectrometric detection has been developed and used for the determination of 2-methylthio-cytokinin derivatives produced by the phytopathogenic actinomycete Rhodococcus fascians. The cultivation medium containing secreted cytokinins was concentrated and subjected to a solid-phase extraction (C18 and ion-exchange). The purified samples were further separated and analyzed by HPLC-ESI-MS/MS. This allowed to achieve chromatographic resolution of six highly hydrophobic cytokinin species including 2-methylthio-isopentenyladenine, 2-methylthio-isopentenyladenosine, 2-methylthio-trans-zeatin and 2-methylthio-trans-zeatin riboside and their cis-isomers when a reversed-phase chromatographic column (C4) and a mobile phase consisting of acetonitrile and 20 mM ammonium formate, pH 5, were used. Quantification was performed by a standard isotope dilution method using a multiple-reaction monitoring (MRM) mode. In the MRM mode, limits of detection reached 20-30 fmol and linear ranges spanned four orders of magnitude. Recovery values were between 35% and 65% and the analytical accuracy between 95% and 149%. The proposed bioanalytical method, which takes advantage of effective chromatographic separation of six 2-methyltio-derivatives (including isomers of zeatin-type cytokinins) and sensitive mass spectrometric detection, may become useful for plant biologists studying the significance of these substances in plant-microbe interactions.

  8. Analysis of 2-methylthio-derivatives of isoprenoid cytokinins by liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Tarkowski, Petr; Vaclavikova, Katerina; Novak, Ondrej; Pertry, Ine; Hanus, Jan; Whenham, Robert; Vereecke, Danny; Sebela, Marek; Strnad, Miroslav

    2010-01-01

    A sensitive and reliable high-performance liquid chromatographic method with tandem mass spectrometric detection has been developed and used for the determination of 2-methylthio-cytokinin derivatives produced by the phytopathogenic actinomycete Rhodococcus fascians. The cultivation medium containing secreted cytokinins was concentrated and subjected to a solid-phase extraction (C18 and ion-exchange). The purified samples were further separated and analyzed by HPLC-ESI-MS/MS. This allowed to achieve chromatographic resolution of six highly hydrophobic cytokinin species including 2-methylthio-isopentenyladenine, 2-methylthio-isopentenyladenosine, 2-methylthio-trans-zeatin and 2-methylthio-trans-zeatin riboside and their cis-isomers when a reversed-phase chromatographic column (C4) and a mobile phase consisting of acetonitrile and 20 mM ammonium formate, pH 5, were used. Quantification was performed by a standard isotope dilution method using a multiple-reaction monitoring (MRM) mode. In the MRM mode, limits of detection reached 20-30 fmol and linear ranges spanned four orders of magnitude. Recovery values were between 35% and 65% and the analytical accuracy between 95% and 149%. The proposed bioanalytical method, which takes advantage of effective chromatographic separation of six 2-methyltio-derivatives (including isomers of zeatin-type cytokinins) and sensitive mass spectrometric detection, may become useful for plant biologists studying the significance of these substances in plant-microbe interactions.

  9. Determination of iodine to compliment mass spectrometric measurements

    International Nuclear Information System (INIS)

    Hohorst, F.A.

    1994-11-01

    The dose of iodine-129 to facility personnel and the general public as a result of past, present, and future activities at DOE sites is of continuing interest, WINCO received about 160 samples annually in a variety of natural matrices, including snow, milk, thyroid tissue, and sagebrush, in which iodine-129 is determined in order to evaluate this dose, Currently, total iodine and the isotopic ratio of iodine-127 to iodine-129 are determined by mass spectrometry. These two measurements determine the concentration of iodine-129 in each sample, These measurements require at least 16 h of mass spectrometer operator time for each sample. A variety of methods are available which concentrate and determine small quantities of iodine. Although useful, these approaches would increase both time and cost. The objective of this effort was to determine total iodine by an alternative method in order to decrease the load on mass spectrometry by 25 to 50%. The preparation of each sample for mass spectrometric analysis involves a common step--collection of iodide on an ion exchange bed. This was the focal point of the effort since the results would be applicable to all samples

  10. A rapid gas chromatographic injection-port derivatization method for the tandem mass spectrometric determination of patulin and 5-hydroxymethylfurfural in fruit juices.

    Science.gov (United States)

    Marsol-Vall, Alexis; Balcells, Mercè; Eras, Jordi; Canela-Garayoa, Ramon

    2016-07-01

    A novel method consisting of injection-port derivatization coupled to gas chromatography-tandem mass spectrometry is described. The method allows the rapid assessment of 5-hydroxymethylfurfural (HMF) and patulin content in apple and pear derivatives. The chromatographic separation of the compounds was achieved in a short chromatographic run (12.2min) suitable for routine controls of these compounds in the fruit juice industry. The optimal conditions for the injection-port derivatization were at 270°C, 0.5min purge-off, and a 1:2 sample:derivatization reagent ratio (v/v). These conditions represent an important saving in terms of derivatization reagent consumption and sample preparation time. Quality parameters were assessed for the target compounds, giving LOD of 0.7 and 1.6μg/kg and LOQ of 2 and 5μg/kg for patulin and HMF, respectively. These values are below the maximum patulin concentration in food products intended for infants and young children. Repeatability (%RSD n=5) was below 12% for both compounds. In addition, the method linearity ranged between 25 and 1000μg/kg and between 5 and 192μg/kg for HMF and patulin, respectively. Finally, the method was applied to study HMF and patulin content in various fruit juice samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Mass spectrometry. [in organic chemistry

    Science.gov (United States)

    Burlingame, A. L.; Shackleton, C. H. L.; Howe, I.; Chizhov, O. S.

    1978-01-01

    A review of mass spectrometry in organic chemistry is given, dealing with advances in instrumentation and computer techniques, selected topics in gas-phase ion chemistry, and applications in such fields as biomedicine, natural-product studies, and environmental pollution analysis. Innovative techniques and instrumentation are discussed, along with chromatographic-mass spectrometric on-line computer techniques, mass spectral interpretation and management techniques, and such topics in gas-phase ion chemistry as electron-impact ionization and decomposition, photoionization, field ionization and desorption, high-pressure mass spectrometry, ion cyclotron resonance, and isomerization reactions of organic ions. Applications of mass spectrometry are examined with respect to bio-oligomers and their constituents, biomedically important substances, microbiology, environmental organic analysis, and organic geochemistry.

  12. Terverticillate Penicillia studied by direct electrospray mass spectrometric profiling of crude extracts: I. Chemosystematics

    DEFF Research Database (Denmark)

    Smedsgaard, Jørn; Frisvad, Jens Christian

    1997-01-01

    ) and Yeast Extract Sucrose agar (YES) directly into the electrospray source of the mass spectrometer. A data matrix was made from each substrate by transferring the complete centroid mass spectrum from 200 to 700 amu as 501 variables to individual columns. No attempt was made to identify ions in the mass......A chemosystematic study of 339 isolates from all known terverticillate Penicillium taxa was performed using electrospray mass spectrometric analysis of extractable metabolites. The mass profiles were made by injecting crude plug extracts made from cultures grown on Czapek Yeast Autolysate agar (CYA...

  13. Functional proteomics with new mass spectrometric and bioinformatics tools

    International Nuclear Information System (INIS)

    Kesners, P.W.A.

    2001-01-01

    A comprehensive range of mass spectrometric tools is required to investigate todays life science applications and a strong focus is on addressing the needs of functional proteomics. Application examples are given showing the streamlined process of protein identification from low femtomole amounts of digests. Sample preparation is achieved with a convertible robot for automated 2D gel picking, and MALDI target dispensing. MALDI-TOF or ESI-MS subsequent to enzymatic digestion. A choice of mass spectrometers including Q-q-TOF with multipass capability, MALDI-MS/MS with unsegmented PSD, Ion Trap and FT-MS are discussed for their respective strengths and applications. Bioinformatics software that allows both database work and novel peptide mass spectra interpretation is reviewed. The automated database searching uses either entire digest LC-MS n ESI Ion Trap data or MALDI MS and MS/MS spectra. It is shown how post translational modifications are interactively uncovered and de-novo sequencing of peptides is facilitated

  14. A review on the mass spectrometric studies of americium: Present status and future perspective.

    Science.gov (United States)

    Aggarwal, Suresh Kumar

    2018-01-01

    The manuscript reviews the various mass spectrometric techniques for analysis and chemical studies of Americium. These methods include thermal ionization mass spectrometry (TIMS), and inductively coupled plasma source mass spectrometry (ICPMS) for the determination of Am isotope ratios and concentration in nuclear fuel samples of interest in nuclear technology, and in complex biological and environmental samples. Ultra-sensitive mass spectrometric techniques of resonance-ionization mass spectrometry (RIMS), and accelerator-based mass spectrometry (AMS) are also discussed. The novel applications of electrospray ionization mass spectrometry (ESIMS) to understand the solution chemistry of Am and other actinides are presented. These studies are important in view of the world-wide efforts to develop novel complexing agents to separate lanthanides and minor actinides (Am, Np, and Cm) for partitioning and transmutation of minor actinides from the point of view of nuclear waste management. These mass spectrometry experiments are also of great interest to examine the covalent character of actinides with increasing atomic number. Studies on gas-phase chemistry of Am and its oxides with Knudsen effusion mass spectrometry (KEMS), Fourier-transform ion cyclotron resonance mass spectrometry (FTICR-MS), and laser-based experiments with reflectron time-of-flight mass spectrometer (R-ToF) are highlighted. These studies are important to understand the fundamental chemistry of 5f electrons in actinides. Requirement of certified isotopic reference materials of Am to improve the accuracy of experimental nuclear data (e.g., the half-life of 243 Am) is emphasized. © 2016 Wiley Periodicals, Inc. Mass Spec Rev. © 2016 Wiley Periodicals, Inc.

  15. Determination of Triazine Herbicides in Drinking Water by Dispersive Micro Solid Phase Extraction with Ultrahigh-Performance Liquid Chromatography-High-Resolution Mass Spectrometric Detection.

    Science.gov (United States)

    Chen, Dawei; Zhang, Yiping; Miao, Hong; Zhao, Yunfeng; Wu, Yongning

    2015-11-11

    A novel dispersive micro solid phase extraction (DMSPE) method based on a polymer cation exchange material (PCX) was applied to the simultaneous determination of the 30 triazine herbicides in drinking water with ultrahigh-performance liquid chromatography-high-resolution mass spectrometric detection. Drinking water samples were acidified with formic acid, and then triazines were adsorbed by the PCX sorbent. Subsequently, the analytes were eluted with ammonium hydroxide/acetonitrile. The chromatographic separation was performed on an HSS T3 column using water (4 mM ammonium formate and 0.1% formic acid) and acetonitrile (0.1% formic acid) as the mobile phase. The method achieved LODs of 0.2-30.0 ng/L for the 30 triazines, with recoveries in the range of 70.5-112.1%, and the precision of the method was better than 12.7%. These results indicated that the proposed method had the advantages of convenience and high efficiency when applied to the analysis of the 30 triazines in drinking water.

  16. Chromatographic method of measurement of helium concentration in underground waters for dating in hydrological questions

    International Nuclear Information System (INIS)

    Najman, J.

    2008-04-01

    Research methods which use natural environmental indicators are widely applied in hydrology. Different concentrations of indicators and their isotopic components in ground waters allow to determine the genesis of waters and are valuable source of information about the water flow dynamics. One of the significant indicator is helium. The concentration of 4 He (helium) in ground water is a fine indicator in water dating in a range from a hundreds to millions of years (Aeschbach-Hertig i in., 1999; Andrews i in., 1989; Castro i in., 2000; Zuber i in., 2007). 4 He is also used for dating young waters of age about 10 years (Solomon i in., 1996). Thesis consist the description of elaborated in IFJ PAN in Krakow chromatographic measurement method of helium concentration in ground waters in aim of dating. Chapter 1 contain short introduction about ground water dating and chapter 2 description of helium property and chosen applications of helium for example in technology and earthquake predictions. Helium sources in ground waters are described in chapter 3. Helium concentration in water after infiltration (originated from atmosphere) to the ground water system depends mainly on the helium concentration coming from the equilibration with the atmosphere increased by additional concentration from '' excess air ''. With the increasing resistance time of ground water during the flow, radiogenic, non-atmospheric component of helium dissolves also in water. In chapter 4 two measurement methods of helium concentration in ground waters were introduced: mass spectrometric and gas chromatographic method. Detailed description of elaborated chromatographic measurement method of helium concentration in ground water contain chapter 5. To verify developed method the concentration of helium in ground waters from the regions of Krakow and Busko Zdroj were measured. For this waters the concentrations of helium are known from the earlier mass spectrometric measurements. The results of

  17. Liquid chromatographic-tandem mass spectrometric determination of selected sulphonamides in milk

    NARCIS (Netherlands)

    Rhijn, van J.A.; Lasaroms, J.J.P.; Berendsen, B.J.A.; Brinkman, U.A.Th.

    2002-01-01

    Liquid chromatography–tandem mass spectrometry is used for the quantitative analysis of selected sulphonamides in milk. Ultrafiltration is the only sample pre-treatment technique which is required. Consequently, sample throughput is much higher than with conventional procedures, and analyte

  18. Mass spectrometric identification of molecular species of phosphatidylcholine and lysophosphatidycholine extracted from shark liver

    NARCIS (Netherlands)

    Chen, S.; Li, K.W.

    2007-01-01

    The profile and structural characterization of molecular species of phosphatidylcholine (PC) and lysophosphatidylcholine (LysoPC) from shark liver using liquid chromatographic/electrospray ionization mass spectrometry (LC-ESI/MS) and tandem mass spectrometry (MS/MS) are described for the first time

  19. Liquid chromatographic-mass spectrometric method for ...

    African Journals Online (AJOL)

    and weighed with the analytical balance. .... was analyzed occasionally to ensure the .... Retention time .... The authors declare that this work was done by .... Life Sci. 2002; 767: 341–351. 31. US Pharmacopeial Convention. United States.

  20. Liquid chromatographic-mass spectrometric method for ...

    African Journals Online (AJOL)

    Pharmacotherapy Group, Faculty of Pharmacy, University of Benin, Benin City, 300001 Nigeria. All rights reserved. ... Additionally, tablet splitting can minimize treatment costs for patients. [6]. ..... using the design space approach. Talanta. 2013 ...

  1. Electrospray ionization mass spectrometric investigations of [alpha]-dicarbonyl compounds--Probing intermediates formed in the course of the nonenzymatic browning reaction of l-ascorbic acid

    Science.gov (United States)

    Schulz, Anke; Trage, Claudia; Schwarz, Helmut; Kroh, Lothar W.

    2007-05-01

    A new method is presented which allows the simultaneous detection of various [alpha]-dicarbonyl compounds generated in the course of the nonenzymatic browning reaction initiated by thermal treatment of l-ascorbic acid, namely: glyoxal, methylglyoxal, diacetyl, 3-deoxy-l-pentosone, and l-threosoneE 3-Deoxy-l-threosone was successfully identified as a new C4-[alpha]-dicarbonyl structure for the first time in the degradation of Vitamin C by application of this non-chromatographic mass spectrometric approach. Moreover, a more detailed elucidation of the mechanistic scenario with respect to the oxidative and nonoxidative pathways is presented by using dehydro-l-ascorbic acid and 2,3-diketo-l-gulonic acid instead of l-ascorbic acid as a starting material. Furthermore, the postulated pathways are corroborated with the aid of 13C-isotopic labeling studies. The investigations were extended to baby food, and the successful detection of [alpha]-dicarbonyl compounds characteristic for Vitamin C degradation proved the matrix tolerance of the introduced method.

  2. Mass spectrometric confirmation criterion for product-ion spectra generated in flow-injection analysis. Environmental application

    NARCIS (Netherlands)

    Geerdink, R.B.; Niessen, W.M.A.; Brinkman, U.A.T.

    2001-01-01

    The suitability of a confirmation criterion recently recommended in the Netherlands for gas chromatography with mass spectrometric detection (GC-MS), was evaluated for flow-injection analysis (FIA) with atmospheric pressure chemical ionisation MS-MS detection. The main feature of the criterion is

  3. Automated multi-plug filtration cleanup for liquid chromatographic-tandem mass spectrometric pesticide multi-residue analysis in representative crop commodities.

    Science.gov (United States)

    Qin, Yuhong; Zhang, Jingru; Zhang, Yuan; Li, Fangbing; Han, Yongtao; Zou, Nan; Xu, Haowei; Qian, Meiyuan; Pan, Canping

    2016-09-02

    An automated multi-plug filtration cleanup (m-PFC) method on modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) extracts was developed. The automatic device was aimed to reduce labor-consuming manual operation workload in the cleanup steps. It could control the volume and the speed of pulling and pushing cycles accurately. In this work, m-PFC was based on multi-walled carbon nanotubes (MWCNTs) mixed with other sorbents and anhydrous magnesium sulfate (MgSO4) in a packed tip for analysis of pesticide multi-residues in crop commodities followed by liquid chromatography with tandem mass spectrometric (LC-MS/MS) detection. It was validated by analyzing 25 pesticides in six representative matrices spiked at two concentration levels of 10 and 100μg/kg. Salts, sorbents, m-PFC procedure, automated pulling and pushing volume, automated pulling speed, and pushing speed for each matrix were optimized. After optimization, two general automated m-PFC methods were introduced to relatively simple (apple, citrus fruit, peanut) and relatively complex (spinach, leek, green tea) matrices. Spike recoveries were within 83 and 108% and 1-14% RSD for most analytes in the tested matrices. Matrix-matched calibrations were performed with the coefficients of determination >0.997 between concentration levels of 10 and 1000μg/kg. The developed method was successfully applied to the determination of pesticide residues in market samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. GNU polyxmass: a software framework for mass spectrometric simulations of linear (bio-polymeric analytes

    Directory of Open Access Journals (Sweden)

    Rusconi Filippo

    2006-04-01

    Full Text Available Abstract Background Nowadays, a variety of (bio-polymers can be analyzed by mass spectrometry. The detailed interpretation of the spectra requires a huge number of "hypothesis cycles", comprising the following three actions 1 put forth a structural hypothesis, 2 test it, 3 (invalidate it. This time-consuming and painstaking data scrutiny is alleviated by using specialized software tools. However, all the software tools available to date are polymer chemistry-specific. This imposes a heavy overhead to researchers who do mass spectrometry on a variety of (bio-polymers, as each polymer type will require a different software tool to perform data simulations and analyses. We developed a software to address the lack of an integrated software framework able to deal with different polymer chemistries. Results The GNU polyxmass software framework performs common (bio-chemical simulations–along with simultaneous mass spectrometric calculations–for any kind of linear bio-polymeric analyte (DNA, RNA, saccharides or proteins. The framework is organized into three modules, all accessible from one single binary program. The modules let the user to 1 define brand new polymer chemistries, 2 perform quick mass calculations using a desktop calculator paradigm, 3 graphically edit polymer sequences and perform (bio-chemical/mass spectrometric simulations. Any aspect of the mass calculations, polymer chemistry reactions or graphical polymer sequence editing is configurable. Conclusion The scientist who uses mass spectrometry to characterize (bio-polymeric analytes of different chemistries is provided with a single software framework for his data prediction/analysis needs, whatever the polymer chemistry being involved.

  5. Retrospective detection of exposure to organophosphorus anti-cholinesterases: Mass spectrometric analysis of phosphylated human butyrylcholinesterase

    NARCIS (Netherlands)

    Fidder, A.; Hulst, A.G.; Noort, D.; Ruiter, R. de; Schans, M.J. van der; Benschop, H.P.; Langenberg, J.P.

    2002-01-01

    In this paper a novel and general procedure is presented for detection of organophosphate-inhibited human butyrylcholinesterase (HuBuChE), which is based on electrospray tandem mass spectrometric analysis of phosphylated nonapeptides obtained after pepsin digestion of the enzyme. The utility of this

  6. Vaporization of niobium dioxide by mass-effusion and mass-spectrometric methods

    International Nuclear Information System (INIS)

    Kamegashira, N.; Matsui, T.; Harada, M.; Naito, K.

    1981-01-01

    The congruence of the vaporization process of NbO, NbO 2 , Nb 12 O 29 and Nb 2 O 5 in the niobium-oxygen system was investigated from the phase change of the solid residue after vaporization, and it was observed that only the NbO 2 phase vaporizes congruently. The vapor pressures over NbO 2 (s) were measured by means of a combination of mass-effusion (weight loss measurement) and mass-spectrometric methods in the temperature range 1953-2323 K. By applying the second and the third law treatments of thermodynamics to the partial pressures of the gaseous species NbO 2 (g), NbO(g) and O(g), the enthalpies of vaporization for the reactions NbO 2 (s,1)=NbO 2 (g) and NbO 2 (s,1)=NbO(g)+O(g), were calculated. From these data the enthalpies of formation and the dissociation energies of NbO 2 (g) and NbO(g) were also determined. The uncertainties included in the third law treatment were discussed, and the results calculated by the third law treatment using the most reliable data available at present were presented. (orig.)

  7. On the Origin of Microheterogeneity : A Mass Spectrometric Study of Dimethyl Sulfoxide-Water Binary Mixture

    NARCIS (Netherlands)

    Shin, Dong Nam; Wijnen, Jan W.; Engberts, Jan B.F.N.; Wakisaka, Akihiro

    2001-01-01

    We have studied the microscopic solvent structure of dimethyl sulfoxide-water mixtures and its influence on the solvation structure of solute from a clustering point of View, by means of a specially designed mass spectrometric system. It was observed that the propensity to the cluster formation is

  8. Determination of trace quantities of uranium in rocks mass spectrometric isotope dilution technique

    International Nuclear Information System (INIS)

    Kakazu, Mauricio Hiromitu

    1980-01-01

    A detailed experimental investigation on the thermionic emission of uranium deposited on a single flat type rhenium filament has been carried out. The study was aimed at determining the influence of various forms of deposition on the emission sensitivity and thermal stability of U + , UO + and UO 2 + ions. Based on these investigations, a technique, involving an addition of a small quantity of colloidal suspension of graphite on top of the uranyl nitrate sample deposited, was chosen because of its higher, emission sensitivity for uranium metal ions. The experimental parameters of the technique were optimised and the technique was employed in the determination of trace quantities of uranium in rock samples using mass spectrometric isotope dilution method. For the mass spectrometric isotope dilution analysis National Bureau of Standards uranium isotopic standard NBS-U 970 was employed as a tracer, where as the mass discrimination effect in the uranium isotope analysis was corrected using the uranium isotopic standard NBS-U500. Uranium was determined in each of the seven granite samples from Wyoming, USA and two USGS standard rocks. The precision of the analysis was found to be ±1% . The uranium values obtained on the rock samples were compared with the analyses of other investigators. Influence of the sample splitting on the uranium analysis was discussed in the light of the analytical results obtained.(author)

  9. Study of matrix effects on the direct trace analysis of acidic pesticides in water using various liquid chromatographic modes coupled to tandem mass spectrometric detection.

    Science.gov (United States)

    Dijkman, E; Mooibroek, D; Hoogerbrugge, R; Hogendoorn, E; Sancho, J V; Pozo, O; Hernández, F

    2001-08-10

    This study investigated the effects of matrix interferences on the analytical performance of a triple quadrupole mass spectrometric (MS-MS) detector coupled to various reversed-phase liquid chromatographic (LC) modes for the on-line determination of various types of acidic herbicides in water using external calibration for quantification of the analytes tested at a level of 0.4 microg/l. The LC modes included (i) a single-column configuration (LC), (ii) precolumn switching (PC-LC) and (iii) coupled-column LC (LC-LC). As regards detection, electrospray (ESI) and atmospheric pressure chemical ionization (APCI) in both positive (PI) and negative (NI) ionization modes were examined. Salinity and dissolved organic carbon (DOC) were selected as interferences to study matrix effects in this type of analysis. Therefore, Milli-Q and tap water samples both fortified with 12 mg/l DOC and spiked with sulfometuron-methyl, bentazone, bromoxynil, 2-methyl-4-chlorophenoxyacetic acid, and 2-methyl-4-chlorophenoxypropionic acid at a level of about 0.4 microg/l were analyzed with the various LC-MS approaches. Direct sample injection was performed with volumes of 0.25 ml or 2.0 ml on a column of 2.1 mm I.D. or 4.6 mm I.D. for the ESI and APCI modes, respectively. The recovery data were used to compare and evaluate the analytical performance of the various LC approaches. As regards matrix effects, the salinity provided a dramatic decrease in response for early eluting analytes (k value of about 1) when using the LC mode. Both PC-LC and LC-LC efficiently eliminated this problem. The high DOC content hardly effected the responses of analytes in the ESI mode, while in most cases the responses increased when using APCI-MS-MS detection. Of all the tested configurations, LC-LC-ESI-MS-MS with the column combination Discovery C18/ABZ+ was the most favorable as regards elimination of matrix effects and provided reliable quantification of all compounds using external calibration at the tested

  10. Determination of thromboxanes, leukotrienes and lipoxins using high-temperature capillary liquid chromatography-tandem mass spectrometry and on-line sample preparation

    DEFF Research Database (Denmark)

    Dahl, Sandra Rinne; Kleiveland, Charlotte Ramstad; Kassem, Moustapha

    2009-01-01

    An on-line strong cation-exchange (SCX)-reversed-phase (RP) capillary liquid chromatographic (cLC) method with ion-trap tandem mass spectrometric (IT-MS/MS) detection for the simultaneous determination of thromboxane (TX) B(2), TXB(3), leukotriene (LT) B(4), LTD(4) and lipoxin (LX) A(4) in cell...

  11. Surface acoustic wave nebulization facilitating lipid mass spectrometric analysis.

    Science.gov (United States)

    Yoon, Sung Hwan; Huang, Yue; Edgar, J Scott; Ting, Ying S; Heron, Scott R; Kao, Yuchieh; Li, Yanyan; Masselon, Christophe D; Ernst, Robert K; Goodlett, David R

    2012-08-07

    Surface acoustic wave nebulization (SAWN) is a novel method to transfer nonvolatile analytes directly from the aqueous phase to the gas phase for mass spectrometric analysis. The lower ion energetics of SAWN and its planar nature make it appealing for analytically challenging lipid samples. This challenge is a result of their amphipathic nature, labile nature, and tendency to form aggregates, which readily precipitate clogging capillaries used for electrospray ionization (ESI). Here, we report the use of SAWN to characterize the complex glycolipid, lipid A, which serves as the membrane anchor component of lipopolysaccharide (LPS) and has a pronounced tendency to clog nano-ESI capillaries. We also show that unlike ESI SAWN is capable of ionizing labile phospholipids without fragmentation. Lastly, we compare the ease of use of SAWN to the more conventional infusion-based ESI methods and demonstrate the ability to generate higher order tandem mass spectral data of lipid A for automated structure assignment using our previously reported hierarchical tandem mass spectrometry (HiTMS) algorithm. The ease of generating SAWN-MS(n) data combined with HiTMS interpretation offers the potential for high throughput lipid A structure analysis.

  12. Derivatization reagents in liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Santa, Tomofumi

    2011-01-01

    Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds. 2010 John Wiley & Sons, Ltd.

  13. Standard test methods for chemical and mass spectrometric analysis of nuclear-grade gadolinium oxide (Gd2O3) powder

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 These test methods cover procedures for the chemical and mass spectrometric analysis of nuclear-grade gadolinium oxide powders to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Carbon by Direct CombustionThermal Conductivity C1408 Test Method for Carbon (Total) in Uranium Oxide Powders and Pellets By Direct Combustion-Infrared Detection Method Total Chlorine and Fluorine by Pyrohydrolysis Ion Selective Electrode C1502 Test Method for Determination of Total Chlorine and Fluorine in Uranium Dioxide and Gadolinium Oxide Loss of Weight on Ignition 7-13 Sulfur by CombustionIodometric Titration Impurity Elements by a Spark-Source Mass Spectrographic C761 Test Methods for Chemical, Mass Spectrometric, Spectrochemical,Nuclear, and Radiochemical Analysis of Uranium Hexafluoride C1287 Test Method for Determination of Impurities In Uranium Dioxide By Inductively Coupled Plasma Mass Spectrometry Gadolinium Content in Gadolinium Oxid...

  14. Mass Spectrometric C-14 Detection Techniques: Progress Report

    Science.gov (United States)

    Synal, H.

    2013-12-01

    Accelerator Mass Spectrometry (AMS) has been established as the best-suited radiocarbon detection technique. In the past years, significant progress with AMS instrumentation has been made resulting in a boom of new AMS facilities around the World. Today, carbon only AMS systems predominantly utilize 1+ charge state and molecule destruction in multiple ion gas collisions in stripper gas cell. This has made possible a significant simplification of the instruments, a reduction of ion energies and related to this less required space of the installations. However, state-of-the-art AMS instruments have still not reached a development stage where they can be regarded as table-top systems. In this respect, more development is needed to further advance the applicability of radiocarbon not only in the traditional fields of dating but also in biomedical research and new fields in Earth and environmental sciences. In a the proof-of-principle experiment the feasibility of radiocarbon detection over the entire range of dating applications was demonstrated using a pure mass spectrometer and ion energies below 50 keV. Now an experimental platform has been completed to test performance and to explore operation and measurement conditions of pure mass spectrometric radiocarbon detection. This contribution will overview the physical principles, which make this development possible and discuss key parameters of the instrumental design and performance of such an instrument.

  15. Liquid chromatographic-tandem mass spectrometric method for the simultaneous determination of alkylphenols polyethoxylates, alkylphenoxy carboxylates and alkylphenols in wastewater and surface-water.

    Science.gov (United States)

    Ciofi, L; Ancillotti, C; Chiuminatto, U; Fibbi, D; Checchini, L; Orlandini, S; Del Bubba, M

    2014-10-03

    Four different pellicular stationary phases (i.e. octadecylsilane, octasilane, Phenyl-Hexyl and pentafluorophenyl) were investigated for the chromatographic resolution of alkylphenols (APs), alkylphenols polyethoxylates (APnEOs) and alkylphenoxy carboxylates (APECs) using mixtures of water and organic solvents (i.e. methanol, acetonitrile and tetrahydrofuran) as eluents, in order to obtain their determination by a single LC-MS/MS run. In fact, alkylphenols and alkylphenoxy carboxylates must be analysed in negative ion mode, whereas alkylphenols polyethoxylates undergo ionisation only in positive ion mode, and therefore, two distinct LC-MS/MS analysis are commonly adopted. The best resolution among the aforementioned target analytes was achieved on the pentafluorophenyl column, eluting with an acidified water-acetonitrile-tetrahydrofuran mixture and using the post column addition of an ammonia solution in methanol for the detection of positively ionisable compounds. Under these optimized chromatographic conditions the investigated compounds were determined via a single chromatographic run, with only one polarity switch, in 15min, achieving the following instrumental detection limits: 600pg for AP1EOs, 0.8-14pg for AP2EOs, 10.4-150pg for APs and 4.4-4.8pg for APECs. The chromatographic method was coupled with solid-phase extraction and clean-up procedures and successfully applied to the analysis of wastewater and surface water samples, highlighting mean concentration ranging from 6ng/L for 4-t-OP1EC to 1434ng/L for 4-NP1121EC, depending on the sample analysed. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. The downfall of TBA-354 - a possible explanation for its neurotoxicity via mass spectrometric imaging.

    Science.gov (United States)

    Ntshangase, Sphamandla; Shobo, Adeola; Kruger, Hendrik G; Asperger, Arndt; Niemeyer, Dagmar; Arvidsson, Per I; Govender, Thavendran; Baijnath, Sooraj

    2017-10-13

    1. TBA-354 was a promising antitubercular compound with activity against both replicating and static Mycobacterium tuberculosis (M.tb), making it the focal point of many clinical trials conducted by the TB Alliance. However, findings from these trials have shown that TBA-354 results in mild signs of reversible neurotoxicity; this left the TB Alliance with no other choice but to stop the research. 2. In this study, mass spectrometric methods were used to evaluate the pharmacokinetics and spatial distribution of TBA-354 in the brain using a validated liquid chromatography tandem-mass spectrometry (LCMS/MS) and mass spectrometric imaging (MSI), respectively. Healthy female Sprague-Dawley rats received intraperitoneal (i.p.) doses of TBA-354 (20 mg/kg bw). 3. The concentrationtime profiles showed a gradual absorption and tissue penetration of TBA-354 reaching the C max at 6 h post dose, followed by a rapid elimination. MSI analysis showed a time-dependent drug distribution, with highest drug concentration mainly in the neocortical regions of the brain. 4. The distribution of TBA-354 provides a possible explanation for the motor dysfunction observed in clinical trials. These results prove the importance of MSI as a potential tool in preclinical evaluations of suspected neurotoxic compounds.

  17. Warping methods for spectroscopic and chromatographic signal alignment: A tutorial

    Energy Technology Data Exchange (ETDEWEB)

    Bloemberg, Tom G., E-mail: T.Bloemberg@science.ru.nl [Radboud University Nijmegen, Institute for Molecules and Materials, Heyendaalseweg 135, 6525 AJ Nijmegen (Netherlands); Radboud University Nijmegen, Education Institute for Molecular Sciences, Heyendaalseweg 135, 6525 AJ Nijmegen (Netherlands); Gerretzen, Jan; Lunshof, Anton [Radboud University Nijmegen, Institute for Molecules and Materials, Heyendaalseweg 135, 6525 AJ Nijmegen (Netherlands); Wehrens, Ron [Centre for Research and Innovation, Fondazione Edmund Mach, Via E. Mach, 1, 38010 San Michele all’Adige, TN (Italy); Buydens, Lutgarde M.C. [Radboud University Nijmegen, Institute for Molecules and Materials, Heyendaalseweg 135, 6525 AJ Nijmegen (Netherlands)

    2013-06-05

    Highlights: •The concepts of warping and alignment are introduced. •The most important warping methods are critically reviewed and explained. •Reference selection, evaluation and place of warping in preprocessing are discussed. •Some pitfalls, especially for LC–MS and similar data, are addressed. •Examples are provided, together with programming scripts to rework and extend them. -- Abstract: Warping methods are an important class of methods that can correct for misalignments in (a.o.) chemical measurements. Their use in preprocessing of chromatographic, spectroscopic and spectrometric data has grown rapidly over the last decade. This tutorial review aims to give a critical introduction to the most important warping methods, the place of warping in preprocessing and current views on the related matters of reference selection, optimization, and evaluation. Some pitfalls in warping, notably for liquid chromatography–mass spectrometry (LC–MS) data and similar, will be discussed. Examples will be given of the application of a number of freely available warping methods to a nuclear magnetic resonance (NMR) spectroscopic dataset and a chromatographic dataset. As part of the Supporting Information, we provide a number of programming scripts in Matlab and R, allowing the reader to work the extended examples in detail and to reproduce the figures in this paper.

  18. Sequential mass spectrometric analysis of uranium and plutonium employing resin bead technique

    International Nuclear Information System (INIS)

    Ramakumar, K.L.; Aggarwal, S.K.; Chitambar, S.A.; Jain, H.C.

    1985-01-01

    Sequential mass spectrometric analysis of uranium and plutonium employing anion exchange resin bead technique is reported using a high sensitive single stage magnetic analyser instrument, the routinely employed rhenium double filament assembly and 0.5M HNO 3 as a wetting agent for loading the resin beads. A precision of bettter than 0.3per cent (2sigma) is obtained on the isotopic ratio measurements. However, extreme care has to be exercised to carry the resin bead experiments under ultra clean conditions so as to avoid pick up of contamination. (author)

  19. Comparison of accelerator mass spectrometric measurement with liquid scintillation counting measurement for the determination of 14C in environmental samples

    International Nuclear Information System (INIS)

    Yasuike, Kaeko; Yamada, Yoshimune; Amano, Hikaru

    2010-01-01

    The concentrations of organically-bound 14 C in tree-ring cellulose of a Japanese Black Pine grown in Shika-machi (37.0 deg. N, 136.8 deg. E) and those of a Japanese Cedar grown in Kanazawa (36.5 deg. N, 136.7 deg. E), Japan, were analyzed for the ring-years from 1989 to 1998 by the accelerator mass spectrometric measurement. The results were compared with those of the same samples analyzed by the liquid scintillation counting measurement to determine the reliability of liquid scintillation counting measurement. An important result of this study is that the sensitivity and reproducibility of accelerator mass spectrometric measurement was almost equal to that of liquid scintillation counting measurement.

  20. Status of mass spectrometric radiocarbon detection at ETHZ

    Energy Technology Data Exchange (ETDEWEB)

    Seiler, Martin; Maxeiner, Sascha; Wacker, Lukas; Synal, Hans-Arno

    2015-10-15

    A prototype of a mass spectrometric radiocarbon detection instrument without accelerator stage was built for the first time and set into operation at ETH Zurich. The system is designed as an experimental platform to optimize performance of {sup 14}C detection at low ion energies and to study the most relevant processes that may limit system performance. The optimized stripper unit incorporates differential pumping to maintain a low gas outflow and a revised tube design to better match the phase space volume of the ion beam at low energies. The system is fully operational and has demonstrated true radiocarbon dating capabilities. The overall beam transmission through the stripper tube is about 40% for the 1{sup +} charge state. Radiocarbon analyses with an overall precision of 0.6% were obtained on a single sample under regular measurement conditions. By analyzing multiple targets of the same sample material an uncertainty level of 0.3% has been reached. The background level corresponds to a radiocarbon age of 40,000 years.

  1. Development, validation and application of an ultra high performance liquid chromatographic-tandem mass spectrometric method for the simultaneous detection and quantification of five different classes of veterinary antibiotics in swine manure.

    Science.gov (United States)

    Van den Meersche, Tina; Van Pamel, Els; Van Poucke, Christof; Herman, Lieve; Heyndrickx, Marc; Rasschaert, Geertrui; Daeseleire, Els

    2016-01-15

    In this study, a fast, simple and selective ultra high performance liquid chromatographic-tandem mass spectrometric (UHPLC-MS/MS) method for the simultaneous detection and quantification of colistin, sulfadiazine, trimethoprim, doxycycline, oxytetracycline and ceftiofur and for the detection of tylosin A in swine manure was developed and validated. First, a simple extraction procedure with acetonitrile and 6% trichloroacetic acid was carried out. Second, the supernatant was evaporated and the pellet was reconstituted in 1 ml of water/acetonitrile (80/20) and 0.1% formic acid. Extracts were filtered and analyzed by UHPLC-MS/MS on a Kinetex C18 column using gradient elution. The method developed was validated according to the criteria of Commission Decision 2002/657/EC. Recovery percentages varied between 94% and 106%, repeatability percentages were within the range of 1.7-9.2% and the intralaboratory reproducibility varied between 2.8% and 9.3% for all compounds, except for tylosin A for which more variation was observed resulting in a higher measurement uncertainty. The limit of detection and limit of quantification varied between 1.1 and 20.2 and between 3.5 and 67.3 μg/kg, respectively. This method was used to determine the presence and concentration of the seven antibiotic residues in swine manure sampled from ten different manure pits on farms where the selected antibiotics were used. A link was found between the antibiotics used and detected, except for ceftiofur which is injected at low doses and degraded readily in swine manure and was therefore not recovered in any of the samples. To the best of our knowledge, this is the first method available for the simultaneous extraction and quantification of colistin with other antibiotic classes. Additionally, colistin was never extracted from swine manure before. Another innovative aspect of this method is the simultaneous detection and quantification of five different classes of antibiotic residues in swine manure

  2. In situ monitoring of molecular changes during cell differentiation processes in marine macroalgae through mass spectrometric imaging.

    Science.gov (United States)

    Kessler, Ralf W; Crecelius, Anna C; Schubert, Ulrich S; Wichard, Thomas

    2017-08-01

    Matrix-assisted laser desorption/ionization mass spectrometric imaging (MALDI-MSI) was employed to discriminate between cell differentiation processes in macroalgae. One of the key developmental processes in the algal life cycle is the production of germ cells (gametes and zoids). The gametogenesis of the marine green macroalga Ulva mutabilis (Chlorophyta) was monitored by metabolomic snapshots of the surface, when blade cells differentiate synchronously into gametangia and giving rise to gametes. To establish MSI for macroalgae, dimethylsulfoniopropionate (DMSP), a known algal osmolyte, was determined. MSI of the surface of U. mutabilis followed by chemometric data analysis revealed dynamic metabolomic changes during cell differentiation. DMSP and a total of 55 specific molecular biomarkers, which could be assigned to important stages of the gametogenesis, were detected. Our research contributes to the understanding of molecular mechanisms underlying macroalgal cell differentiation. Graphical abstract Molecular changes during cell differentiation of the marine macroalga Ulva were visualized by matrix assisted laser desorption/ionization mass spectrometric imaging (MALDI-MSI).

  3. Liquid chromatographic-tandem mass spectrometric assay for ...

    African Journals Online (AJOL)

    for simultaneous quantitation of tofacitinib, cabozantinib ... The method was validated with regard to its limits of .... quantitative determination of TOF alone was .... prepared in human plasma only. Blank plasma/urine samples were similarly ...

  4. Gas chromatographic and mass spectrometric analysis of ...

    Indian Academy of Sciences (India)

    Unknown

    Following oral administration three major metabolites of ... It is well established that the stimulating anabolic effect of ... oral application of a single dose of clostebol (dose,. 20 mg) ..... 17â and testosterone production by ovarian follicles of the.

  5. Topic model-based mass spectrometric data analysis in cancer biomarker discovery studies.

    Science.gov (United States)

    Wang, Minkun; Tsai, Tsung-Heng; Di Poto, Cristina; Ferrarini, Alessia; Yu, Guoqiang; Ressom, Habtom W

    2016-08-18

    A fundamental challenge in quantitation of biomolecules for cancer biomarker discovery is owing to the heterogeneous nature of human biospecimens. Although this issue has been a subject of discussion in cancer genomic studies, it has not yet been rigorously investigated in mass spectrometry based proteomic and metabolomic studies. Purification of mass spectometric data is highly desired prior to subsequent analysis, e.g., quantitative comparison of the abundance of biomolecules in biological samples. We investigated topic models to computationally analyze mass spectrometric data considering both integrated peak intensities and scan-level features, i.e., extracted ion chromatograms (EICs). Probabilistic generative models enable flexible representation in data structure and infer sample-specific pure resources. Scan-level modeling helps alleviate information loss during data preprocessing. We evaluated the capability of the proposed models in capturing mixture proportions of contaminants and cancer profiles on LC-MS based serum proteomic and GC-MS based tissue metabolomic datasets acquired from patients with hepatocellular carcinoma (HCC) and liver cirrhosis as well as synthetic data we generated based on the serum proteomic data. The results we obtained by analysis of the synthetic data demonstrated that both intensity-level and scan-level purification models can accurately infer the mixture proportions and the underlying true cancerous sources with small average error ratios (data, we found more proteins and metabolites with significant changes between HCC cases and cirrhotic controls. Candidate biomarkers selected after purification yielded biologically meaningful pathway analysis results and improved disease discrimination power in terms of the area under ROC curve compared to the results found prior to purification. We investigated topic model-based inference methods to computationally address the heterogeneity issue in samples analyzed by LC/GC-MS. We observed

  6. Identification of organic iodocompounds in the PUREX process with the help of methods for chromatographic separation and spectrometric detection as well as characterization of their behavior during extraction. Final report

    International Nuclear Information System (INIS)

    Gaul, G.; Gibau, F.; Knoechel, A.

    1993-01-01

    In the system HNO 3 KI, Dodecan and TBP the radiolytic reactive behaviour of the described compounds during the dissolution of nuclear fuel elements was simulated. External γ-irradiation gave the best informations. As a consequence of radiolyticly induced reactions several volatile and non-volatile iodoorganic compounds like iodoalkanes, iodonitroalkanes and iodonitroalkylphosphates are formed. They were separated by gaschromatography (GC) and high performance liquid chromatography (HPLC). For HPLC a special photolytic/electrochemical detector with comparable sensitivity like the electroncapture detector in the GC-field was developed. With the help of the two described chromatographic techniques the different iodoorganic compounds could be separated singularily or in groups of isomers. The separation of all compounds demands two-dimensional chromatographies including the capillary-SFC, which was not available for this project. Most of the iodoorganic compounds could be identified by comparison of the retention times of well known compounds. In the other cases, the compounds were studied mass-spectrometrically. Unfortunately all available ionisation techniques (EI; CI; FAB) were too hard for the labile C-I-bond. Therefore an identification of these compounds was not possible. In any case, instructive fingerprint spectra are available enabling relationships between the generation of the iodoorganic compounds and the reaction conditions during their formation. (orig.) [de

  7. Mass spectrometric behaviour of carboxylated polyethylene glycols and carboxylated octylphenol ethoxylates.

    Science.gov (United States)

    Frańska, Magdalena; Zgoła, Agnieszka; Rychłowska, Joanna; Szymański, Andrzej; Łukaszewski, Zenon; Frański, Rafał

    2003-01-01

    Mass spectrometric behaviour of mono- and di-carboxylated polyethylene glycols (PEGCs and CPEGCs) and carboxylated octylphenol ethoxylates (OPECs) are discussed. The tendency for ionisation (deprotonation, protonation and cationisation by alkali metal cations) of carboxylated PEGs was compared with that of non-carboxylated correspondents by using both secondary ion mass spectrometry (SIMS) and electrospray ionisation (ESI). The fragmentation of the PEGCs and CPEGCs is discussed and also compared with their neutral correspondents, PEGs. The B/E mass spectra were recorded, using secondary ion mass spectrometry as a method for generation, for deprotonated and protonated molecules and molecules cationised by alkali metal cations. The fragmentation behaviour of PEGs is found to be different from that of CPEGCs, The presence of carboxylic groups may be confirmed not only by the determination of molecular weights of the ethoxylates studied, but also on the basis of the fragment ions formed. The metastable decomposition of the [OPEC-H](-) ions proceed through the cleavage of the bond between the octylphenol moiety and the ethoxylene chain leading to the octylphenoxy anions. It permits determination of the mass of the hydrophobic moiety of the studied carboxylated alkylphenol ethoxylate. ESI mass spectra recorded in the negative ion mode were found to be more suitable for the determination of the average molecular weight of carboxylated ethoxylates than SI mass spectra.

  8. Development of liquid chromatographic methods for the determination of phytosterols in Standard Reference Materials containing saw palmetto.

    Science.gov (United States)

    Bedner, Mary; Schantz, Michele M; Sander, Lane C; Sharpless, Katherine E

    2008-05-23

    Liquid chromatographic (LC) methods using atmospheric pressure chemical ionization/mass spectrometric (APCI-MS) detection were developed for the separation and analysis of the phytosterols campesterol, cycloartenol, lupenone, lupeol, beta-sitosterol, and stigmasterol. Brassicasterol and cholesterol were also included for investigation as internal standards. The methods were used to identify and quantify the phytosterols in each of two Serenoa repens (saw palmetto) Standard Reference Materials (SRMs) developed by the National Institute of Standards and Technology (NIST). Values obtained by LC-MS were compared to those obtained using the more traditional approach of gas chromatography with flame ionization detection. This is the first reported use of LC-MS to determine phytosterols in saw palmetto dietary supplement materials.

  9. Knudsen cell mass spectrometric study of the Cs2IOH(g) molecule thermodynamics

    International Nuclear Information System (INIS)

    Roki, F-Z.; Ohnet, M-N.; Fillet, S.; Chatillon, C.; Nuta, I.

    2013-01-01

    Highlights: • The pronounced ionic character leads to only dissociative ionization processes. • Ions formed are same as those coming from pure dimmers. • De-convolution of the ions origin needs accurate thermodynamic values for the pure gas phase. • Mass spectrometric interpretation has to be performed gradually and as a function of suitable condensed compositions. • Thermal functions have to be fully estimated. -- Abstract: The gas phase of the CsI + CsOH system is analyzed by high temperature Knudsen cell mass spectrometry in order to confirm the existence of the Cs 2 IOH(g) complex molecule. The mass spectrometric analysis is quite complex since such molecules undergo dissociative ionization into fragment ions that mix with the same ions from dimers of the pure compounds in the same vapor phase. Varying the chemical conditions for vaporization by using different CsI + CsOH mixture contents showed that the ionization of the Cs 2 IOH(g) molecule led to five different fragment ions, Cs 2 OH + , Cs 2 I + , Cs + , CsOH + and CsI + . This complex ionization pattern was studied in relation with previous assessed values for the vaporization of CsOH and CsI pure compounds in which monomer and dimer molecules are predominant. The equilibrium constant for the reaction CsI(g) + CsOH(g) = Cs 2 IOH(g) was determined and, after modeling the structure of the Cs 2 IOH molecule, the enthalpy of formation was determined using the third law of thermodynamics, as follows: Δ f H°(Cs 2 IOH, g, 298.15 K) = −578 ± 14.7 kJ · mole −1

  10. Bead Injection Extraction Chromatography using High-capacity Lab-on-Valve as a Front End to Inductively Coupled Plasma Mass Spectrometry for Rapid Urine Radiobioassay

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2013-01-01

    A novel bead injection (BI) extraction chromatographic microflow system exploiting high-capacity lab-on-valve (LOV) platform coupled with inductively coupled plasma mass spectrometric detection is developed for rapid and automated determination of plutonium in human urine. A microconduit (1 m......L) incorporated within the LOV processing unit is loaded on-line with a metered amount of disposable extraction chromatographic resin (up to 330 mg of TEVA) through programmable beads transport. Selective capture and purification of plutonium onto the resin beads is then performed by pressure driven flow after...

  11. iMS2Flux – a high–throughput processing tool for stable isotope labeled mass spectrometric data used for metabolic flux analysis

    Directory of Open Access Journals (Sweden)

    Poskar C Hart

    2012-11-01

    Full Text Available Abstract Background Metabolic flux analysis has become an established method in systems biology and functional genomics. The most common approach for determining intracellular metabolic fluxes is to utilize mass spectrometry in combination with stable isotope labeling experiments. However, before the mass spectrometric data can be used it has to be corrected for biases caused by naturally occurring stable isotopes, by the analytical technique(s employed, or by the biological sample itself. Finally the MS data and the labeling information it contains have to be assembled into a data format usable by flux analysis software (of which several dedicated packages exist. Currently the processing of mass spectrometric data is time-consuming and error-prone requiring peak by peak cut-and-paste analysis and manual curation. In order to facilitate high-throughput metabolic flux analysis, the automation of multiple steps in the analytical workflow is necessary. Results Here we describe iMS2Flux, software developed to automate, standardize and connect the data flow between mass spectrometric measurements and flux analysis programs. This tool streamlines the transfer of data from extraction via correction tools to 13C-Flux software by processing MS data from stable isotope labeling experiments. It allows the correction of large and heterogeneous MS datasets for the presence of naturally occurring stable isotopes, initial biomass and several mass spectrometry effects. Before and after data correction, several checks can be performed to ensure accurate data. The corrected data may be returned in a variety of formats including those used by metabolic flux analysis software such as 13CFLUX, OpenFLUX and 13CFLUX2. Conclusion iMS2Flux is a versatile, easy to use tool for the automated processing of mass spectrometric data containing isotope labeling information. It represents the core framework for a standardized workflow and data processing. Due to its flexibility

  12. Gas chromatographic/mass spectrometric characterization of dromostanolone metabolites in human urine

    International Nuclear Information System (INIS)

    Kim, Tae Wook; Choi, Man Ho; Jung, Byung Hwa; Chung, Bong Chul

    1998-01-01

    The metabolism of dromostanolone (2α-methyl-5α-androstan-17β-ol-3-one) was studied in three adult volunteers after oral dose of 20 mg. Solvent extracts of urine obtained after enzyme hydrolysis were derivatized with MSTFA/TMCS and MSTFA/TMIS. The structures of intact drug and its metabolites were determined by gas chromatography/mass spectrometry (GC/MS) in electron impact (EI) mode. The major metabolite (2α-methyl-5α-androstan-3α-ol-17-one), its 3β-epimer, parent compound, and several hydroxylated metabolites including intact drug were detected by comparing total ion chromatograms of control urine with that of the administered sample. Two epimers of 2α-methyl-5α-androstan-3, 17β-diol were detected using selected ion monitoring. The maximum excretion of dromostanolone and 2α-methyl-5α-androstan-3α-ol-17-one was reached in 6.2-15 hr. The half-life of intact dromostanolone was 5.3 hr. About 3.0% of the administered amount was found to be excreted within 95 hr as unchanged form

  13. Continued development of an atmospheric monitoring mass spectrometry system - task 2.2. Topical report, January 1, 1995 - December 31, 1995

    International Nuclear Information System (INIS)

    King, F.L.

    1998-01-01

    The objective of this project was the development of a mass spectrometric methodology applicable to the field determination of Volatile Organic Compounds (VOC's), such as BTEX components (Benzene, Toluene, Ethylbenzene, and Xylenes). A combination of chemical ionization, selective ion storage, and tandem mass spectrometry was planned to be employed with an ion trap mass spectrometry system. The Gas Chromatography Mass Spectrometry (GC-MS) interface on the ion trap system was modified to permit direct atmospheric monitoring. Through the use of tandem mass spectrometry methods the need for chromatographic separation would be eliminated reducing the overall size and complexity of the system

  14. How mass spectrometric approaches applied to bacterial identification have revolutionized the study of human gut microbiota.

    Science.gov (United States)

    Grégory, Dubourg; Chaudet, Hervé; Lagier, Jean-Christophe; Raoult, Didier

    2018-03-01

    Describing the human hut gut microbiota is one the most exciting challenges of the 21 st century. Currently, high-throughput sequencing methods are considered as the gold standard for this purpose, however, they suffer from several drawbacks, including their inability to detect minority populations. The advent of mass-spectrometric (MS) approaches to identify cultured bacteria in clinical microbiology enabled the creation of the culturomics approach, which aims to establish a comprehensive repertoire of cultured prokaryotes from human specimens using extensive culture conditions. Areas covered: This review first underlines how mass spectrometric approaches have revolutionized clinical microbiology. It then highlights the contribution of MS-based methods to culturomics studies, paying particular attention to the extension of the human gut microbiota repertoire through the discovery of new bacterial species. Expert commentary: MS-based approaches have enabled cultivation methods to be resuscitated to study the human gut microbiota and thus to fill in the blanks left by high-throughput sequencing methods in terms of culturing minority populations. Continued efforts to recover new taxa using culture methods, combined with their rapid implementation in genomic databases, would allow for an exhaustive analysis of the gut microbiota through the use of a comprehensive approach.

  15. Increased Protein Structural Resolution from Diethylpyrocarbonate-based Covalent Labeling and Mass Spectrometric Detection

    Science.gov (United States)

    Zhou, Yuping; Vachet, Richard W.

    2012-04-01

    Covalent labeling and mass spectrometry are seeing increased use together as a way to obtain insight into the 3-dimensional structure of proteins and protein complexes. Several amino acid specific (e.g., diethylpyrocarbonate) and non-specific (e.g., hydroxyl radicals) labeling reagents are available for this purpose. Diethylpyrocarbonate (DEPC) is a promising labeling reagent because it can potentially probe up to 30% of the residues in the average protein and gives only one reaction product, thereby facilitating mass spectrometric analysis. It was recently reported, though, that DEPC modifications are labile for some amino acids. Here, we show that label loss is more significant and widespread than previously thought, especially for Ser, Thr, Tyr, and His residues, when relatively long protein digestion times are used. Such label loss ultimately decreases the amount of protein structural information that is obtainable with this reagent. We find, however, that the number of DEPC modified residues and, thus, protein structural information, can be significantly increased by decreasing the time between the covalent labeling reaction and the mass spectrometric analysis. This is most effectively accomplished using short (e.g., 2 h) proteolytic digestions with enzymes such as immobilized chymotrypsin or Glu-C rather than using methods (e.g., microwave or ultrasonic irradiation) that accelerate proteolysis in other ways. Using short digestion times, we show that the percentage of solvent accessible residues that can be modified by DEPC increases from 44% to 67% for cytochrome c, 35% to 81% for myoglobin, and 76% to 95% for β-2-microglobulin. In effect, these increased numbers of modified residues improve the protein structural resolution available from this covalent labeling method. Compared with typical overnight digestion conditions, the short digestion times decrease the average distance between modified residues from 11 to 7 Å for myoglobin, 13 to 10 Å for

  16. In situ probing of cholesterol in astrocytes at the single-cell level using laser desorption ionization mass spectrometric imaging with colloidal silver.

    Science.gov (United States)

    Perdian, D C; Cha, Sangwon; Oh, Jisun; Sakaguchi, Donald S; Yeung, Edward S; Lee, Young Jin

    2010-04-30

    Mass spectrometric imaging has been utilized to localize individual astrocytes and to obtain cholesterol populations at the single-cell level in laser desorption ionization (LDI) with colloidal silver. The silver ion adduct of membrane-bound cholesterol was monitored to detect individual cells. Good correlation between mass spectrometric and optical images at different cell densities indicates the ability to perform single-cell studies of cholesterol abundance. The feasibility of quantification is confirmed by the agreement between the LDI-MS ion signals and the results from a traditional enzymatic fluorometric assay. We propose that this approach could be an effective tool to study chemical populations at the cellular level. Published in 2010 by John Wiley & Sons, Ltd.

  17. 2DB: a Proteomics database for storage, analysis, presentation, and retrieval of information from mass spectrometric experiments.

    Science.gov (United States)

    Allmer, Jens; Kuhlgert, Sebastian; Hippler, Michael

    2008-07-07

    The amount of information stemming from proteomics experiments involving (multi dimensional) separation techniques, mass spectrometric analysis, and computational analysis is ever-increasing. Data from such an experimental workflow needs to be captured, related and analyzed. Biological experiments within this scope produce heterogenic data ranging from pictures of one or two-dimensional protein maps and spectra recorded by tandem mass spectrometry to text-based identifications made by algorithms which analyze these spectra. Additionally, peptide and corresponding protein information needs to be displayed. In order to handle the large amount of data from computational processing of mass spectrometric experiments, automatic import scripts are available and the necessity for manual input to the database has been minimized. Information is in a generic format which abstracts from specific software tools typically used in such an experimental workflow. The software is therefore capable of storing and cross analysing results from many algorithms. A novel feature and a focus of this database is to facilitate protein identification by using peptides identified from mass spectrometry and link this information directly to respective protein maps. Additionally, our application employs spectral counting for quantitative presentation of the data. All information can be linked to hot spots on images to place the results into an experimental context. A summary of identified proteins, containing all relevant information per hot spot, is automatically generated, usually upon either a change in the underlying protein models or due to newly imported identifications. The supporting information for this report can be accessed in multiple ways using the user interface provided by the application. We present a proteomics database which aims to greatly reduce evaluation time of results from mass spectrometric experiments and enhance result quality by allowing consistent data handling

  18. 2DB: a Proteomics database for storage, analysis, presentation, and retrieval of information from mass spectrometric experiments

    Directory of Open Access Journals (Sweden)

    Hippler Michael

    2008-07-01

    Full Text Available Abstract Background The amount of information stemming from proteomics experiments involving (multi dimensional separation techniques, mass spectrometric analysis, and computational analysis is ever-increasing. Data from such an experimental workflow needs to be captured, related and analyzed. Biological experiments within this scope produce heterogenic data ranging from pictures of one or two-dimensional protein maps and spectra recorded by tandem mass spectrometry to text-based identifications made by algorithms which analyze these spectra. Additionally, peptide and corresponding protein information needs to be displayed. Results In order to handle the large amount of data from computational processing of mass spectrometric experiments, automatic import scripts are available and the necessity for manual input to the database has been minimized. Information is in a generic format which abstracts from specific software tools typically used in such an experimental workflow. The software is therefore capable of storing and cross analysing results from many algorithms. A novel feature and a focus of this database is to facilitate protein identification by using peptides identified from mass spectrometry and link this information directly to respective protein maps. Additionally, our application employs spectral counting for quantitative presentation of the data. All information can be linked to hot spots on images to place the results into an experimental context. A summary of identified proteins, containing all relevant information per hot spot, is automatically generated, usually upon either a change in the underlying protein models or due to newly imported identifications. The supporting information for this report can be accessed in multiple ways using the user interface provided by the application. Conclusion We present a proteomics database which aims to greatly reduce evaluation time of results from mass spectrometric experiments and enhance

  19. Cu2+-assisted two dimensional charge-mass double focusing gel electrophoresis and mass spectrometric analysis of histone variants.

    Science.gov (United States)

    Zhang, Wenyang; Tang, Xuemei; Ding, Mengjie; Zhong, Hongying

    2014-12-10

    Abundant isoforms and dynamic posttranslational modifications cause the separation and identification of histone variants to be experimentally challenging. To meet this need, we employ two-dimensional electrophoretic gel separation followed by mass spectrometric detection which takes advantage of the chelation of Cu(2+) with amino acid residues exposed on the surfaces of the histone proteins. Acid-extracted rat liver histones were first mixed with CuSO4 solution and then separated in one dimension with triton-acid-urea (TAU) gel electrophoresis and in a second dimension using sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). The separations result from both the changes in charge and mass upon Cu(2+) chelation. Identities of each separated gel bands were obtained by using matrix-assisted laser desorption-ionization mass spectrometry (MALDI-MS). It was found that the migration of H3 histone isoforms of rat liver is markedly affected by the use of Cu(2+) ions. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Environmental Technology Verification Report. Field Portable Gas Chromatograph/Mass Spectrometer. Viking Instruments Corporation SpectraTrak (Trademark) 672

    National Research Council Canada - National Science Library

    Enfield, Wayne

    1997-01-01

    .... This self-contained, field transportable system, whose design has been adapted from laboratory technology, uses a contained, chromatographic column and accompanying mass spectrometer to provide...

  1. Mass Spectrometric Calibration of Controlled Fluoroform Leak Rate Devices Technique and Uncertainty Analysis

    CERN Document Server

    Balsley, S D; Laduca, C A

    2003-01-01

    Controlled leak rate devices of fluoroform on the order of 10 sup - sup 8 atm centre dot cc sec sup - sup 1 at 25 C are used to calibrate QC-1 War Reserve neutron tube exhaust stations for leak detection sensitivity. Close-out calibration of these tritium-contaminated devices is provided by the Gas Dynamics and Mass Spectrometry Laboratory, Organization 14406, which is a tritium analytical facility. The mass spectrometric technique used for the measurement is discussed, as is the first principals calculation (pressure, volume, temperature and time). The uncertainty of the measurement is largely driven by contributing factors in the determination of P, V and T. The expanded uncertainty of the leak rate measurement is shown to be 4.42%, with a coverage factor of 3 (k=3).

  2. Mass spectrometric study of vaporization of cesium tellurate and tellurite

    International Nuclear Information System (INIS)

    Semenov, G.A.; Fokina, L.A.; Mouldagalieva, R.A.

    1994-01-01

    The process of vaporization of cesium tellurate and tellurite was studied by the Knudsen effusion method with a mass spectrometric analysis of the vapor composition. The thermal dissociation of Cs 2 TeO 4 to Cs 2 TeO 3 and the congruent vaporization of Cs 2 TeO 3 were established. Thermodynamic functions for gaseous Cs 2 TeO 3 have been calculated. The standard enthalpy of sublimation Δ s H (298.15)=268.1±13.0 kJ mol -1 was determined by the 2nd and 3rd laws of thermodynamics. The enthalpy of formation Δ f H (298.15)=-725.1±13.0 kJ mol -1 for gaseous Cs 2 TeO 3 and the enthalpy of atomization Δ at H (298.15)=1841.3±15.0 kJ mol -1 have been computed. ((orig.))

  3. Mass spectrometric study of rhamnolipid biosurfactants and their interactions with cell membrane phospholipids

    Directory of Open Access Journals (Sweden)

    Pashynska V. A.

    2009-12-01

    Full Text Available Aim. To examine the formation of supramolecular complexes of biogenous rhamnolipids with membrane phospholipids that is considered as a molecular mechanism of the biosurfactants antimicrobial action. Method. In the present work rhamnolipid biosurfactant samples produced by Pseudomonas sp. PS-17 strain have been investigated by electrospray ionization mass spectrometry for the first time. Results. As a result of the study, characteristic mass spectra of the rhamnolipid samples were obtained, that can be used as reference spectra for mass spectrometric identification of the compounds in any biological or industrial samples. At the next stage of the experiments the pair systems, containing the biosurfactants and a membrane phospholipid dipalmitoylphosphatidylcholine, have been tested. The cationized noncovalent complexes of the rhamnolipids with the phospholipid were observed in the spectra. Conclusions. The results obtained testify to the consideration that rhamnolipids (similar to other membranotropic agents can form stable supramolecular complexes with membrane phospholipids that are able to evoke the biosurfactants antimicrobial action. A great potential of electrospray ionization mass spectrometry for the biosurfactants identification and study has been demonstrated in the work.

  4. Determination of isotope fractionation effect using a double spike (242Pu+240Pu) during the mass spectrometric analysis of plutonium

    International Nuclear Information System (INIS)

    Chitambar, S.A.; Parab, A.R.; Khodade, P.S.; Jain, H.C.

    1986-01-01

    Isotope fractionation effect during the mass spectrometric analysis of plutonium has been investigated using a double spike ( 242 Pu+ 240 Pu) and the determination of concentration of plutonium in dissolver solution of irradiated fuel is reported. (author). 6 refs., 2 tables

  5. Quantitative mass fragmentographic determination of unlabeled and deuterium-labeled propoxyphene in plasma

    International Nuclear Information System (INIS)

    Sullivan, H.R.; McMahon, R.E.

    1977-01-01

    A quantitative gas chromatographic-mass spectrometric method for determination of plasma levels of d-propoxyphene has been developed by using d-propoxyphene-benzyl-d 7 as internal standard. Steady-state pharmacokinetics were studied in a dog by orally administering d-propoxyphene-d 0 for 19 days and d-propoxyphene-d 2 on the 20th day, and monitoring the plasma levels of both compounds and the ratio for 48 hours. It was established that the use of propoxyphene-d 2 did not lead to an isotope effect

  6. Mass spectrometric-based stable isotopic 2-aminobenzoic acid glycan mapping for rapid glycan screening of biotherapeutics.

    Science.gov (United States)

    Prien, Justin M; Prater, Bradley D; Qin, Qiang; Cockrill, Steven L

    2010-02-15

    Fast, sensitive, robust methods for "high-level" glycan screening are necessary during various stages of a biotherapeutic product's lifecycle, including clone selection, process changes, and quality control for lot release testing. Traditional glycan screening involves chromatographic or electrophoretic separation-based methods, and, although reproducible, these methods can be time-consuming. Even ultrahigh-performance chromatographic and microfluidic integrated LC/MS systems, which work on the tens of minute time scale, become lengthy when hundreds of samples are to be analyzed. Comparatively, a direct infusion mass spectrometry (MS)-based glycan screening method acquires data on a millisecond time scale, exhibits exquisite sensitivity and reproducibility, and is amenable to automated peak annotation. In addition, characterization of glycan species via sequential mass spectrometry can be performed simultaneously. Here, we demonstrate a quantitative high-throughput MS-based mapping approach using stable isotope 2-aminobenzoic acid (2-AA) for rapid "high-level" glycan screening.

  7. Assessment of current mass spectrometric workflows for the quantification of low abundant proteins and phosphorylation sites

    Directory of Open Access Journals (Sweden)

    Manuel Bauer

    2015-12-01

    Full Text Available The data described here provide a systematic performance evaluation of popular data-dependent (DDA and independent (DIA mass spectrometric (MS workflows currently used in quantitative proteomics. We assessed the limits of identification, quantification and detection for each method by analyzing a dilution series of 20 unmodified and 10 phosphorylated synthetic heavy labeled reference peptides, respectively, covering six orders of magnitude in peptide concentration with and without a complex human cell digest background. We found that all methods performed very similarly in the absence of background proteins, however, when analyzing whole cell lysates, targeted methods were at least 5–10 times more sensitive than directed or DDA methods. In particular, higher stage fragmentation (MS3 of the neutral loss peak using a linear ion trap increased dynamic quantification range of some phosphopeptides up to 100-fold. We illustrate the power of this targeted MS3 approach for phosphopeptide monitoring by successfully quantifying 9 phosphorylation sites of the kinetochore and spindle assembly checkpoint component Mad1 over different cell cycle states from non-enriched pull-down samples. The data are associated to the research article ‘Evaluation of data-dependent and data-independent mass spectrometric workflows for sensitive quantification of proteins and phosphorylation sites׳ (Bauer et al., 2014 [1]. The mass spectrometry and the analysis dataset have been deposited to the ProteomeXchange Consortium (http://proteomecentral.proteomexchange.org via the PRIDE partner repository with the dataset identifier PXD000964.

  8. Mass spectrometric determination of magnesium isotopic ratios and its corrections for electron multiplier discrimination and mass fractionation

    International Nuclear Information System (INIS)

    Deng Zhongguo

    1989-01-01

    The mass spectrometric determination of magnesium isotopic ratios by the use of uranyl nitrate added to magnesium samples to act as a binding agent is reported. Prebaking empty filaments and preheating filaments with deposited magnesium samples on its surface in a vacuum are employed to reduce the Na signal from the thenium-ribbon. Methods for correcting magnesium isotopic ratios for electron multiplier discrimination and mass fractionation are described in detail. The results of the determination of natural magnesium isotopic ratios are 25 Mg/ 24 Mg = 0.12660 (1±0.01%) and 26 Mg/ 24 Mg = 0.13938 (1±0.10%). The magnesium isotopic ratios of rich - 26 Mg-2 sample and rich- 25 Mg-1 sample are 24 Mg/ 26 Mg = 0.003463 (1±0.2%), 25 Mg/ 26 Mg = 0.001656 (±0.2%) and 24 Mg/ 25 Mg = 0.006716 (1±0.2%), 26 Mg/ 25 Mg = 0.007264 (1±0.2%) respectively

  9. Determination of suvorexant in human plasma using 96-well liquid-liquid extraction and HPLC with tandem mass spectrometric detection.

    Science.gov (United States)

    Breidinger, S A; Simpson, R C; Mangin, E; Woolf, E J

    2015-10-01

    A method, using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS), was developed for the determination of suvorexant (MK-4305, Belsomra(®)), a selective dual orexin receptor antagonist for the treatment insomnia, in human plasma over the concentration range of 1-1000ng/mL. Stable isotope labeled (13)C(2)H3-suvorexant was used as an internal standard. The sample preparation procedure utilized liquid-liquid extraction, in the 96-well format, of a 100μL plasma sample with methyl t-butyl ether. The compounds were chromatographed under isocratic conditions on a Waters dC18 (50×2.1mm, 3μm) column with a mobile phase consisting of 30/70 (v/v %) 10mM ammonium formate, pH3/acetonitrile at a flow rate of 0.3mL/min. Multiple reaction monitoring of the precursor-to-product ion pairs for suvorexant (m/z 451→186) and (13)C(2)H3-suvorexant (m/z 455→190) on an Applied Biosystems API 4000 tandem mass spectrometer was used for quantitation. Intraday assay precision, assessed in six different lots of control plasma, was within 10% CV at all concentrations, while assay accuracy ranged from 95.6 to 105.0% of nominal. Quality control (QC) samples in plasma were stored at -20°C. Initial within day analysis of QCs after one freeze-thaw cycle showed accuracy within 9.5% of nominal with precision (CV) of 6.7% or less. The plasma QC samples were demonstrated to be stable for up to 25 months at -20°C. The method described has been used to support clinical studies during Phase I through III of clinical development. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Good quantification practices of flavours and fragrances by mass spectrometry.

    Science.gov (United States)

    Begnaud, Frédéric; Chaintreau, Alain

    2016-10-28

    Over the past 15 years, chromatographic techniques with mass spectrometric detection have been increasingly used to monitor the rapidly expanded list of regulated flavour and fragrance ingredients. This trend entails a need for good quantification practices suitable for complex media, especially for multi-analytes. In this article, we present experimental precautions needed to perform the analyses and ways to process the data according to the most recent approaches. This notably includes the identification of analytes during their quantification and method validation, when applied to real matrices, based on accuracy profiles. A brief survey of application studies based on such practices is given.This article is part of the themed issue 'Quantitative mass spectrometry'. © 2016 The Authors.

  11. Direct coupling of a dense (supercritical) gas chromatograph to a mass spectrometer using a supersonic molecular beam interface

    International Nuclear Information System (INIS)

    Randall, L.G.; Wahrhaftig, A.L.

    1981-01-01

    A detecting mass spectrometer has been successfully coupled to a dense gas (supercritical fluid) chromatograph to produce an instrument (DGC/MS) that may be an alternative to high performance liquid chromatograph/mass spectrometer instruments (HPLC/MS) and gas chromatograph/mass spectrometer instruments (GC/MS) for analysis of involatile and/or thermally labile compounds. The mobile phase in DGC is a gas held at temperatures above the critical temperature and at pressures sufficient to obtain nearly liquid-like densities. DGC combines advantages of GC and HPLC: rapid separations, moderate operating temperatures, and analysis of involatile compounds. An advantage unique to DGC is the solvent power dependence upon pressure. While several groups have studied DGC, its development has been limited by the lack of a sensitive and selective detector. Hence, work has been directed towards the design and construction of a DGC/MS resulting in a trial instrument capable of chromatographic pressures of at least 300 atm and temperatures from 10 0 to 60 0 C. The DGC/MS coupling has been accomplished by the use of a supersonic molecular beam interface. This application of molecular beam formation appears to be unique in its requirements of a large pressure ratio (approx.10 8 ), low flow rates, and low final pressures. The authors outline characteristics of supersonic jets and molecular beams pertinent to the design of such an instrument. The interface which uses pumping speeds of 2400 and 1200 l/s in the beam forming chambers is described in detail, while the other components: the detecting mass spectrometer, the dense gas supply, and the DGC: are briefly described. Preliminary work with this instrument has established the feasibility of DGC/MS as an analytical technique and further development is recommended

  12. Recent Advances in Water Analysis with Gas Chromatograph Mass Spectrometers

    Science.gov (United States)

    MacAskill, John A.; Tsikata, Edem

    2014-01-01

    We report on progress made in developing a water sampling system for detection and analysis of volatile organic compounds in water with a gas chromatograph mass spectrometer (GCMS). Two approaches are described herein. The first approach uses a custom water pre-concentrator for performing trap and purge of VOCs from water. The second approach uses a custom micro-volume, split-splitless injector that is compatible with air and water. These water sampling systems will enable a single GC-based instrument to analyze air and water samples for VOC content. As reduced mass, volume, and power is crucial for long-duration, manned space-exploration, these water sampling systems will demonstrate the ability of a GCMS to monitor both air and water quality of the astronaut environment, thereby reducing the amount of required instrumentation for long duration habitation. Laboratory prototypes of these water sampling systems have been constructed and tested with a quadrupole ion trap mass spectrometer as well as a thermal conductivity detector. Presented herein are details of these water sampling system with preliminary test results.

  13. Evaluation of errors for mass-spectrometric analysis with surface-ionization type mass-spectrometer (statistical evaluation of mass-discrimination effect)

    International Nuclear Information System (INIS)

    Wada, Y.

    1981-01-01

    The surface-ionization type mass-spectrometer is widely used as an apparatus for quality assurance, accountability and safeguarding of nuclear materials, and for this analysis it has become an important factor to statistically evaluate an analytical error which consists of a random error and a systematic error. The major factor of this systematic error was the mass-discrimination effect. In this paper, various assays for evaluating the factor of variation on the mass-discrimination effect were studied and the data obtained were statistically evaluated. As a result of these analyses, it was proved that the factor of variation on the mass-discrimination effect was not attributed to the acid concentration of sample, sample size on the filament and supplied voltage for a multiplier, but mainly to the filament temperature during the mass-spectrometric analysis. The mass-discrimination effect values β which were usually calculated from the measured data of uranium, plutonium or boron isotopic standard sample were not so significant dependently of the difference of U-235, Pu-239 or B-10 isotopic abundance. Furthermore, in the case of U and Pu, measurement conditions and the mass range of these isotopes were almost similar, and these values β were not statistically significant between U and Pu. On the other hand, the value β for boron was about a third of the value β for U or Pu, but compared with the coefficient of the correction on the mass-discrimination effect for the difference of mass-number, ΔM, these coefficient values were almost the same among U, Pu, and B.As for the isotopic analysis error of U, Pu, Nd and B, it was proved that the isotopic abundance of these elements and the isotopic analysis error were in a relationship of quadratic curves on a logarithmic-logarithmic scale

  14. Liquid chromatography-tandem mass spectrometric assay for the tyrosine kinase inhibitor afatinib in mouse plasma using salting-out liquid-liquid extraction

    NARCIS (Netherlands)

    Sparidans, Rolf W; van Hoppe, Stephanie; Rood, Johannes J M; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H

    2016-01-01

    A quantitative bioanalytical liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay for afatinib, an irreversible inhibitor of the ErbB (erythroblastic leukemia viral oncogene homolog) tyrosine kinase family, was developed and validated. Plasma samples were pre-treated using salting-out

  15. Reply to "On Vaporization of liquid Pb-Li eutectic alloy from 1000 K to 1200 K- A high temperature mass spectrometric study"

    Science.gov (United States)

    Jain, Uttam; Mukherjee, Abhishek

    2018-03-01

    This communication is in response to a letter to editor commenting on the authors' earlier paper "Vaporization of liquid Pb-Li eutectic alloy from 1000 K to 1200 K - A high temperature mass spectrometric study".

  16. Sr isotope geochemistry of East Alpine mineral deposits and mass spectrometric analyses of fluid inclusions

    International Nuclear Information System (INIS)

    Grum, W.

    1995-05-01

    Strontium isotope geochemistry and deformational history of selected carbonate-hosted deposits from different tectonic positions in the Eastern Alps were studied. In this context an equipment has been constructed to analyze the composition of volatile components of fluid inclusions (FI). Based on the results of Sr-isotopic investigations two groups of deposits are discriminated: Deposits formed by formation waters and/or metamorphogenic fluids: Tux (magnesite, scheelite), Otterzug (barite), Lassing (magnesite), Rabenwald (talc), Laussa and Mooseck (fluorite). The mineralizing fluids are derived from different sedimentary rock series and therefore 87 Sr/ 86 Sr-ratios vary between 0.707 and 0.719. Deposits situated along fault zones: Lassing (talc), Gasteiner Tal (Silberpfennig area; gold), Schlaining (stibnite) and Waldenstein (specularite). Sr isotope ratios of the mineralizing fluids from Lassing, Waldenstein and Schlaining ranges from 0.7112 to 0.7127 and are therefore thought to have scavenged the East Alpine crystalline. The mineralizing solutions of the Gasteiner Tal deposit may either have equilibrated with low radiogenic sedimentary or with (ultra-)basic rocks. A cracking chamber has been constructed in order to open FI by cracking for mass spectrometric analysis of volatile components. Gases are analysed using a quadrupole mass spectrometer. The desorption of gas from metal and sample surfaces during cracking can be neglected. The amount of gas released from the mineral lattices was studied. With that fast method ore bearing from barren host rocks have been distinguished by different composition of the FI at the Brixlegg barite mineralization (Eastern Alps). Within the Galway fluorite deposit (Ireland) different fluids were involved and mass spectrometric analysis were carried out to characterize these different fluids and to identify their origin. (author)

  17. Immunological screening of drugs of abuse and gas chromatographic-mass spectrometric confirmation of opiates and cocaine in hair.

    Science.gov (United States)

    Segura, J; Stramesi, C; Redón, A; Ventura, M; Sanchez, C J; González, G; San, L; Montagna, M

    1999-03-05

    The work presents an analytical strategy to detect drugs of abuse in hair. It involves two sequential steps: a screening by a simple enzyme-linked immunosorbent assay (ELISA) methodology to detect opiates, cocaine and its metabolites, and benzodiacepines, followed by confirmation of opiates and cocaine metabolites in positive samples by gas chromatography coupled to mass spectrometry (GC-MS). In the same GC-MS run other drugs for substitution therapy (e.g. methadone and its main metabolite) can also be detected. After a double washing of hair samples with dichloromethane, hair specimens were cut into small pieces and 10 mg samples were incubated in 2 ml of methanol-trifluoroacetic acid (9:1) mixture, overnight at 37 degrees C. Aliquots of the extract were then evaporated, reconstituted in buffer and analysed according to the ELISA procedure. Confirmation involved solid-phase extraction of another fraction of the extract kept at -20 degrees C, derivatization with heptafluorobutyric anhydride and hexafluoroisopropanol and detection of cocaine, benzoylecgonine, ecgonine methylester, cocaethylene, morphine, codeine, 6-monoacetylmorphine, methadone and 2-ethylidene-1.5-dimethyl-3,3-diphenylpirrolidine (methadone metabolite) by selective ion monitoring after gas chromatographic separation. During the development of the method it was verified that no more than 10% of cocaine, opiates and benzodiacepines were lost when dichloromethane was used to wash real samples. The results also confirmed the increase of extractability power of TFA when it was added to methanol: the recovery for the analytes (cocaine and its metabolites and opiates) added to methanol-TFA alone was of the order of 90% except for benzoylecgonine (75%), and the recovery for the analytes added to methanol-TFA extract of drug-free hair was about 90% for all analytes except for benzoylecgonine and 6-MAM (around 70%). Regarding the stability of labile compounds, only small amounts of ecgonine methylester (2

  18. Gas Chromatographic-Mass Spectrometric Analysis of Essential Oil ...

    African Journals Online (AJOL)

    hepatitis, dysmenorrhea, stomatitis, duodenitis and depression in south China [1]. There are few reports about its chemical constituents and pharmacological properties, such as the hydroalcoholic extract from the buds of. Jasminum grandiflorum showing preferable antiviral efficacy against HBV replication in. HepG2 2.2.15 ...

  19. Chromatographic-mass spectrometric analysis of ethanol extract of ...

    African Journals Online (AJOL)

    Purpose: This study analyzes the chemical composition of ethanol root extracts of Maesa perlaria var. formosana by .... obtained over a scanning range of 50 to 550 amu at 2 scans/s. .... 142.53 (2,2,6-Trimethyl-bicyclo[4.1.0]hept-1-yl)-methanol.

  20. Chromatographic-mass spectrometric analysis of ethanol extract of ...

    African Journals Online (AJOL)

    Methods: The dried root of Maesa perlaria var. formosana was extracted with 95 % ethanol for composition analysis under the following optimum GC-MS conditions: 250 °C inlet temperature, 250 °C MSD detector temperature, and GC oven temperature programmed as follows: initial temperature held at 70 °C for 15 min, ...

  1. Mass spectrometric identification of phospholipids in human tears and tear lipocalin.

    Science.gov (United States)

    Dean, Austin W; Glasgow, Ben J

    2012-04-02

    The purpose of this article was to identify by mass spectrometry phosphocholine lipids in stimulated human tears and determine the molecules bound to tear lipocalin or other proteins. Tear proteins were separated isocratically from pooled stimulated human tears by gel filtration fast performance liquid chromatography. Separation of tear lipocalin was confirmed by SDS tricine gradient PAGE. Protein fractions were extracted with chloroform/methanol and analyzed with electrospray ionization MS/MS triple quadrupole mass spectrometry in precursor ion scan mode for select leaving groups. For quantification, integrated ion counts were derived from standard curves of authentic compounds of phosphatidylcholine (PC) and phosphatidylserine. Linear approximation was possible from integration of the mass spectrometrically obtained ion peaks at 760 Da for the PC standard. Tears contained 194 ng/mL of the major intact PC (34:2), m/z 758.6. Ten other monoisotopic phosphocholines were found in tears. A peak at 703.3 Da was assigned as a sphingomyelin. Four lysophosphatidylcholines (m/z 490-540) accounted for about 80% of the total integrated ion count. The [M+H](+) compound, m/z 496.3, accounted for 60% of the signal intensity. Only the tear lipocalin-bearing fractions showed phosphocholines (104 ng/mL). Although the intact phospholipids bound to tear lipocalin corresponded precisely in mass and relative signal intensity to that found in tears, we did not identify phosphocholines between m/z 490 and 540 in any of the gel-filtration fractions. Phospholipids, predominantly lysophospholipids, are present in tears. The higher mass intact PCs in tears are native ligands of tear lipocalin.

  2. Mature forms of the major seed storage albumins in sunflower: A mass spectrometric approach.

    Science.gov (United States)

    Franke, Bastian; Colgrave, Michelle L; Mylne, Joshua S; Rosengren, K Johan

    2016-09-16

    Seed storage albumins are abundant, water-soluble proteins that are degraded to provide critical nutrients for the germinating seedling. It has been established that the sunflower albumins encoded by SEED STORAGE ALBUMIN 2 (SESA2), SESA20 and SESA3 are the major components of the albumin-rich fraction of the common sunflower Helianthus annuus. To determine the structure of sunflowers most important albumins we performed a detailed chromatographic and mass spectrometric characterization to assess what post-translational processing they receive prior to deposition in the protein storage vacuole. We found that SESA2 and SESA20 each encode two albumins. The first of the two SESA2 albumins (SESA2-1) exists as a monomer of 116 or 117 residues, differing by a threonine at the C-terminus. The second of the two SESA2 albumins (SESA2-2) is a monomer of 128 residues. SESA20 encodes the albumin SESA20-2, which is a 127-residue monomer, whereas SESA20-1 was not abundant enough to be structurally described. SESA3, which has been partly characterized previously, was found in several forms with methylation of its asparagine residues. In contrast to other dicot albumins, which are generally matured into a heterodimer, all the dominant mature sunflower albumins SESA2, SESA20-2, SESA3 and its post-translationally modified analogue SESA3-a are monomeric. Sunflower plants have been bred to thrive in various climate zones making them favored crops to meet the growing worldwide demand by humans for protein. The abundance of seed storage proteins makes them an important source of protein for animal and human nutrition. This study explores the structures of the dominant sunflower napin-type seed storage albumins to understand what structures evolution has favored in the most abundant proteins in sunflower seed. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  3. Gas chromatographic-mass spectrometric analysis of biomarkers related to folate and cobalamin status in human serum after dimercaptopropanesulfonate reduction and heptafluorobutyl chloroformate derivatization

    Czech Academy of Sciences Publication Activity Database

    Šimek, Petr; Hušek, Petr; Zahradníčková, Helena

    2008-01-01

    Roč. 80, č. 15 (2008), s. 5776-5782 ISSN 0003-2700 R&D Projects: GA ČR GA303/06/1674 Institutional research plan: CEZ:AV0Z50070508 Keywords : biomarkers * gas chromatographic * chloroformate derivatization Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 5.712, year: 2008

  4. MASS SPECTROMETRIC ANALYSIS FOR THE IDENTIFICATION OF THUNNUS GENUS FOUR SPECIES

    Directory of Open Access Journals (Sweden)

    T. Pepe

    2011-01-01

    Full Text Available An accurate identification of similar fish species is necessary to prevent illegal substitution and is imposed by labeling regulations in UE countries (1. The genus Thunnus comprises many species of different quality and commercial value. The increasing trade of fish preparations of the species included in this genus and the consequent loss of the external anatomical and morphological features enables fraudulent substitutions. This study reports data relating to the proteomic analysis of four tuna species (T. thynnus, T. alalunga, T. albacares, T. obesus. Sarcoplasmic proteins were studied by mono and two dimensional electrophoresis. The most significant proteins for the characterization of the species were analyzed by mass spectrometric techniques. As reported in a previous study (2, an accurate identification of the species seems possible, owing to the polymorphism displayed by the species of the Thunnus genus.

  5. The fast gamma spectrometric method of the Am-241 determination in Chernobyl restricted zone soils

    International Nuclear Information System (INIS)

    Gleisberg, B.; Lukachina, V.V.; Kirsenko, V.N.; Tepikin, V.E.; Rajevsky, V.S.; Libman, V.A.; Stoljarevsky, I.P.; Isajev, A.G.

    1997-01-01

    The known methods of the 241 Am contents determination in environmental objects, as a rule, is based on ion-chromatographic or extraction separation techniques. This approach reflects widespread opinion, that only the α-spectrometric analysis termination is suitable to ensure necessary sensitivity of the overall method of 241 Am actively determination. Really, the minimal detectable activity for such methods is about 0.05 Bq/kg (considering that Am is usually concentrated during separation procedure). However, because of α-spectrometry does not permit to separate the α-peaks of the 241 Am, and 238 Pu, but also in view of high requests to the α-spectrometric specimen purity, the multistage and laborious chemical procedures to separate 241 Am from plutonium radionuclides and other elements (with a thorough control of each separation stage) are needed

  6. Mass spectrometric methods for studying nutrient mineral and trace element absorption and metabolism in humans using stable isotopes: a review

    International Nuclear Information System (INIS)

    Crews, H.M.; Eagles, J.; Mellon, F.A.; Luten, J.B.; McGaw, B.A.

    1994-01-01

    Mass spectrometric methods for determining stable isotopes of nutrient minerals and trace elements in human metabolic studies are described and discussed. The advantages and disadvantages of the techniques of electron ionization, fast atom bombardment, thermal ionization, and inductively coupled plasma and gas chromatography mass spectrometry are evaluated with reference to their accuracy, precision, sensitivity, and convenience, and the demands of human nutrition research. Examples of specific applications are described and the significance of current developments in mass spectrometry are discussed with reference to present and probable future research needs. (Author)

  7. A new ultrafast and high-throughput mass spectrometric approach for the therapeutic drug monitoring of the multi-targeted anti-folate pemetrexed in plasma from lung cancer patients

    NARCIS (Netherlands)

    R.J.W. Meesters (Roland); R. Cornelissen (Robin); R.J. van Klaveren (Rob); R. de Jonge (Robert); E. den Boer (Ethan); J. Lindemans (Jan); T.M. Luider (Theo)

    2010-01-01

    textabstractAn analytical assay has been developed and validated for ultrafast and high-throughput mass spectrometric determination of pemetrexed concentrations in plasma using matrix assisted laser desorption/ionization-triple quadrupole-tandem mass spectrometry. Patient plasma samples spiked with

  8. Mars Solar Balloon Landed Gas Chromatograph Mass Spectrometer

    Science.gov (United States)

    Mahaffy, P.; Harpold, D.; Niemann, H.; Atreya, S.; Gorevan, S.; Israel, G.; Bertaux, J. L.; Jones, J.; Owen, T.; Raulin, F.

    1999-01-01

    A Mars surface lander Gas Chromatograph Mass Spectrometer (GCMS) is described to measure the chemical composition of abundant and trace volatile species and isotope ratios for noble gases and other elements. These measurements are relevant to the study of atmospheric evolution and past climatic conditions. A Micromission plan is under study where a surface package including a miniaturized GCMS would be delivered to the surface by a solar heated hot air balloon based system. The balloon system would be deployed about 8 km above the surface of Mars, wherein it would rapidly fill with Martian atmosphere and be heated quickly by the sun. The combined buoyancy and parachuting effects of the solar balloon result in a surface package impact of about 5 m/sec. After delivery of the package to the surface, the balloon would ascend to about 4 km altitude, with imaging and magnetometry data being taken for the remainder of the daylight hours as the balloon is blown with the Martian winds. Total atmospheric entry mass of this mission is estimated to be approximately 50 kg, and it can fit as an Ariane 5 piggyback payload. The GCMS would obtain samples directly from the atmosphere at the surface and also from gases evolved from solid phase material collected from well below the surface with a Sample Acquisition and Transport Mechanism (SATM). The experiment envisioned in the Mars Micromission described would obtain samples from a much greater depth of up to one meter below the surface, and would search for organic molecules trapped in ancient stratified layers well below the oxidized surface. Insitu instruments on upcoming NASA missions working in concert with remote sensing measurement techniques have the potential to provide a more detailed investigation of mineralogy and the extent of simple volatiles such as CO2 and H2O in surface and subsurface solid phase materials. Within the context of subsequent mission opportunities such as those provided by the Ariane 5 piggyback

  9. Sheath liquid interface for the coupling of normal-phase liquid chromatography with electrospray mass spectrometry and its application to the analysis of neoflavonoids.

    Science.gov (United States)

    Charles, Laurence; Laure, Frédéric; Raharivelomanana, Phila; Bianchini, Jean-Pierre

    2005-01-01

    A novel interface that allows normal-phase liquid chromatography to be coupled with electrospray ionization (ESI) is reported. A make-up solution of 60 mM ammonium acetate in methanol, infused at a 5 microl min(-1) flow-rate at the tip of the electrospray probe, provides a sheath liquid which is poorly miscible with the chromatographic effluent, but promotes efficient ionization of the targeted analytes. Protonated molecules generated in the ESI source were subjected to tandem mass spectrometric experiments in a triple-quadrupole mass spectrometer. The main fragmentation reactions were characterized for each analyte and specific mass spectral transitions were used to acquire chromatographic data in the multiple reaction monitoring detection mode. Results obtained during optimization of the sheath liquid composition and flow-rate suggest that the electrospray process was mainly under the control of the make-up solution, and that it forms an external charged layer around a neutral chromatographic mobile phase core. This sheath liquid interface was implemented for the analysis of some neoflavonoid compounds and its performance was evaluated. Limits of detection were established for calophillolide, inophyllum B, inophyllum P and inophyllum C at 100, 25, 15 and 100 ng ml(-1), respectively.

  10. Principles of qualitative analysis in the chromatographic context.

    Science.gov (United States)

    Valcárcel, M; Cárdenas, S; Simonet, B M; Carrillo-Carrión, C

    2007-07-27

    This article presents the state of the art of qualitative analysis in the framework of the chromatographic analysis. After establishing the differences between two main classes of qualitative analysis (analyte identification and sample classification/qualification) the particularities of instrumental qualitative analysis are commented on. Qualitative chromatographic analysis for sample classification/qualification through the so-called chromatographic fingerprint (for complex samples) or the volatiles profile (through the direct coupling headspace-mass spectrometry using the chromatograph as interface) is discussed. Next, more technical exposition of the qualitative chromatographic information is presented supported by a variety of representative examples.

  11. Mass spectrometric analysis of simple hydrogen compounds; Analyse de composes hydrogenes simples au spectrometre de masse

    Energy Technology Data Exchange (ETDEWEB)

    Nief, C; Botter, R [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    A uranium furnace is inserted in the gas inlet line of a mass spectrometer between the leak and the source. The line is fed with simple hydrogen compounds (H{sub 2}O, NH{sub 3}, H{sub 2}S) which are in this way reduced to hydrogen gas. Memory effects are largely avoided by heating the sample line to 90 deg. C. The speed of the isotopic analysis is only slightly less than that of hydrogen gas itself; the accuracy is better due to the reduction of fractionating effects in the leak. For the absolute measurements of deuterium in water, the presence of H{sub 3}{sup +} is a problem. Water samples, prepared by mixing an unknown light water sample with different amounts of heavy water, are equilibrated with hydrogen sulphide and analysis of the two phases of each sample enables the zero of the concentration scale to be determined from the point of intersection of the two curves obtained by plotting mixture composition against the observed isotope ratio in the two phases. The whole experiment can be carried out in the apparatus described which analyses hydrogen in H{sub 2}S and H{sub 2}O in the same way. (author) [French] Un four a uranium est insere dans la ligne d'introduction de gaz d'un spectrometre de masse entre la fuite et la source. La ligne est alimentee par des composes hydrogenes simples (H{sub 2}O, NH{sub 3}, H{sub 2}S) qui sont de cette facon transformes en hydrogene gazeux. On evite dans une large mesure les effets de memoire en chauffant la ligne de l'echantillon jusqu'a 90 deg. C. La vitesse de l'analyse isotopique est seulement legerement inferieure a celle de l'hydrogene gazeux lui-meme; la precision est meilleure du fait de la reduction des effets de fractionnement dans la fuite. Pour les mesures absolues du deuterium dans l'eau, la presence de H{sub 3}{sup +} pose un probleme. Les echantillons d'eau, prepares en melangeant un echantillon inconnu d'eau legere a differentes quantites d'eau lourde, sont equilibres par de l'hydrogene sulfure et l'analyse de

  12. Mass-Spectrometric Studies of Catalytic Chemical Vapor Deposition Processes of Organic Silicon Compounds Containing Nitrogen

    Science.gov (United States)

    Morimoto, Takashi; Ansari, S. G.; Yoneyama, Koji; Nakajima, Teppei; Masuda, Atsushi; Matsumura, Hideki; Nakamura, Megumi; Umemoto, Hironobu

    2006-02-01

    The mechanism of catalytic chemical vapor deposition (Cat-CVD) processes for hexamethyldisilazane (HMDS) and trisdimethylaminosilane (TDMAS), which are used as source gases to prepare SiNx or SiCxNy films, was studied using three different mass spectrometric techniques: ionization by Li+ ion attachment, vacuum-ultraviolet radiation and electron impact. The results for HMDS show that Si-N bonds dissociate selectively, although Si-C bonds are weaker, and (CH3)3SiNH should be one of the main precursors of deposited films. This decomposition mechanism did not change when NH3 was introduced, but the decomposition efficiency was slightly increased. Similar results were obtained for TDMAS.

  13. Determination of fluspirilene in human plasma by liquid chromatography-tandem mass spectrometry with electrospray ionisation.

    Science.gov (United States)

    Swart, K J; Sutherland, F C; van Essen, G H; Hundt, H K; Hundt, A F

    1998-12-18

    An ultra-sensitive method for the determination of fluspirilene in plasma was established, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted with hexane/isoamyl alcohol, separated on a Phenomenex Luna C18 5 mu 150 x 2.1 mm column with a mobile phase consisting of methanol-water-acetic acid (600:400:1) at a flow-rate of 0.3 ml/min. Detection was achieved by a Finnigan Matt mass spectrometer (LCQ) at unit resolution in full scan mode scanning the product ion spectrum from m/z 130-500 and monitoring the transition of the protonated molecular ion at m/z 476.2, to the sum of the largest product ions m/z 371, 342 and 274 (MS-MS). Electrospray ionisation was used for ion production. The mean recovery for fluspirilene was 90% with a lower limit of quantification of 21.50 pg/ml using 1 ml plasma for extraction. This is the first chromatographic method described for the determination of fluspirilene in plasma that is accurate and sensitive enough to be used in pharmacokinetic studies.

  14. Mass spectrometric isotope dilution analyses of palladium, silver, cadmium and tellurium in carbonaceous chondrites

    International Nuclear Information System (INIS)

    Loss, R.D.; Rosman, K.J.R.; De Laeter, J.

    1984-01-01

    The mass spectrometric isotope dilution technique was used to measure the elemental abundances of Pd, Ag, Cd and Te in Orgueil (C1), Ivuna (C1), Murray (C2) and Allende (C3) chondrites. The Pd abundance of 554 ppb for the Cl chondrites is almost identical to the recommended value of Anders and Ebihara (1982); that for Cd (712 ppb) is approximately 5% higher, whereas that for Ag (198 ppb) is approximately 10% lower than the recommended values. A smooth distribution for the abundances of the odd-A nuclides between 65 128 Te and 130 Te to lie approximately 30% above the r-process peak at A = 130, whereas the new value fits smoothly into the general trend. (author)

  15. Total cholesterol in serum determined by isotope dilution/mass spectrometry, with liquid-chromatographic separation

    International Nuclear Information System (INIS)

    Takatsu, Akiko; Nishi, Sueo

    1988-01-01

    We describe an accurate, precise method for determination of total serum cholesterol by isotope dilution/mass spectrometry (IDMS) with liquid chromatographic separation. After adding [3,4- 13 C] cholesterol to serum and hydrolyzing the cholesterol esters, we extract the total cholesterol. High-performance liquid chromatography (HPLC) is used to separate the extracted cholesterol for measurement by electron-impact mass spectrometry with use of a direct-insertion device. To evaluate the specificity and the accuracy of this method, we also studied the conventional IDMS method, which involves converting cholesterol to the trimethylsilyl ether and assay by gas chromatography-mass spectrometry with use of a capillary column. The coefficient of variation for the HPLC method was a little larger than for the conventional method, but mean values by each method agreed within 1% for all sera tested. (author)

  16. Mass Spectrometric Identification and Differentiation of Botulinum Neurotoxins through Toxin Proteomics.

    Science.gov (United States)

    Kalb, Suzanne R; Barr, John R

    2013-08-01

    Botulinum neurotoxins (BoNTs) cause the disease botulism, which can be lethal if untreated. There are seven known serotypes of BoNT, A-G, defined by their response to antisera. Many serotypes are distinguished into differing subtypes based on amino acid sequence and immunogenic properties, and some subtypes are further differentiated into toxin variants. Toxin characterization is important as different types of BoNT can respond differently to medical countermeasures for botulism, and characterization of the toxin can aid in epidemiologic and forensic investigations. Proteomic techniques have been established to determine the serotype, subtype, or toxin variant of BoNT. These techniques involve digestion of the toxin into peptides, tandem mass spectrometric (MS/MS) analysis of the peptides, and database searching to identify the BoNT protein. These techniques demonstrate the capability to detect BoNT and its neurotoxin-associated proteins, and differentiate the toxin from other toxins which are up to 99.9% identical in some cases. This differentiation can be accomplished from toxins present in a complex matrix such as stool, food, or bacterial cultures and no DNA is required.

  17. Knudsen effusion mass spectrometry. Chapter 20

    International Nuclear Information System (INIS)

    Sai Baba, M.

    1997-01-01

    The Knudsen effusion mass spectrometric method for the determination of vapour pressures and thermodynamic properties is described. The aim of the article is to give a general introduction to the method rather than to give a critical review of the technique. The latest developments in this area of research are reviewed by the peers in the field during the triennial international mass spectrometric conferences. The Knudsen effusion mass spectrometric method is being applied for thermodynamic measurements. In recent times, laser vaporisation mass spectrometric methods have emerged as a source of determination of vapour pressures at very high temperatures and beyond the pressure regime far exceeding Knudsen effusion range

  18. LipidPioneer : A Comprehensive User-Generated Exact Mass Template for Lipidomics

    Science.gov (United States)

    Ulmer, Candice Z.; Koelmel, Jeremy P.; Ragland, Jared M.; Garrett, Timothy J.; Bowden, John A.

    2017-03-01

    Lipidomics, the comprehensive measurement of lipid species in a biological system, has promising potential in biomarker discovery and disease etiology elucidation. Advances in chromatographic separation, mass spectrometric techniques, and novel substrate applications continue to expand the number of lipid species observed. The total number and type of lipid species detected in a given sample are generally indicative of the sample matrix examined (e.g., serum, plasma, cells, bacteria, tissue, etc.). Current exact mass lipid libraries are static and represent the most commonly analyzed matrices. It is common practice for users to manually curate their own lists of lipid species and adduct masses; however, this process is time-consuming. LipidPioneer, an interactive template, can be used to generate exact masses and molecular formulas of lipid species that may be encountered in the mass spectrometric analysis of lipid profiles. Over 60 lipid classes are present in the LipidPioneer template and include several unique lipid species, such as ether-linked lipids and lipid oxidation products. In the template, users can add any fatty acyl constituents without limitation in the number of carbons or degrees of unsaturation. LipidPioneer accepts naming using the lipid class level (sum composition) and the LIPID MAPS notation for fatty acyl structure level. In addition to lipid identification, user-generated lipid m/z values can be used to develop inclusion lists for targeted fragmentation experiments. Resulting lipid names and m/z values can be imported into software such as MZmine or Compound Discoverer to automate exact mass searching and isotopic pattern matching across experimental data.

  19. Targeted selected reaction monitoring mass spectrometric immunoassay for insulin-like growth factor 1.

    Directory of Open Access Journals (Sweden)

    Eric E Niederkofler

    Full Text Available Insulin-like growth factor 1 (IGF1 is an important biomarker of human growth disorders that is routinely analyzed in clinical laboratories. Mass spectrometry-based workflows offer a viable alternative to standard IGF1 immunoassays, which utilize various pre-analytical preparation strategies. In this work we developed an assay that incorporates a novel sample preparation method for dissociating IGF1 from its binding proteins. The workflow also includes an immunoaffinity step using antibody-derivatized pipette tips, followed by elution, trypsin digestion, and LC-MS/MS separation and detection of the signature peptides in a selected reaction monitoring (SRM mode. The resulting quantitative mass spectrometric immunoassay (MSIA exhibited good linearity in the range of 1 to 1,500 ng/mL IGF1, intra- and inter-assay precision with CVs of less than 10%, and lowest limits of detection of 1 ng/mL. The linearity and recovery characteristics of the assay were also established, and the new method compared to a commercially available immunoassay using a large cohort of human serum samples. The IGF1 SRM MSIA is well suited for use in clinical laboratories.

  20. Standard test methods for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover procedures for subsampling and for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride UF6. Most of these test methods are in routine use to determine conformance to UF6 specifications in the Enrichment and Conversion Facilities. 1.2 The analytical procedures in this document appear in the following order: Note 1—Subcommittee C26.05 will confer with C26.02 concerning the renumbered section in Test Methods C761 to determine how concerns with renumbering these sections, as analytical methods are replaced with stand-alone analytical methods, are best addressed in subsequent publications. Sections Subsampling of Uranium Hexafluoride 7 - 10 Gravimetric Determination of Uranium 11 - 19 Titrimetric Determination of Uranium 20 Preparation of High-Purity U3O 8 21 Isotopic Analysis 22 Isotopic Analysis by Double-Standard Mass-Spectrometer Method 23 - 29 Determination of Hydrocarbons, Chlorocarbons, and Partially Substitut...

  1. MassAI

    DEFF Research Database (Denmark)

    2011-01-01

    A software tool for general analysis and data-mining of mass-spectrometric datasets. The program features a strong emphasis on scan-by-scan identification and results-transparency. MassAI also accommodates residue level analysis of labelled runs, e.g. HDX.......A software tool for general analysis and data-mining of mass-spectrometric datasets. The program features a strong emphasis on scan-by-scan identification and results-transparency. MassAI also accommodates residue level analysis of labelled runs, e.g. HDX....

  2. Resolution of a protein sequence ambiguity by X-ray crystallographic and mass spectrometric methods

    International Nuclear Information System (INIS)

    Keefe, L.J.; Lattman, E.E.; Wolkow, C.; Woods, A.; Chevrier, M.; Cotter, R.J.

    1992-01-01

    Ambiguities in amino acid sequences are a potential problem in X-ray crystallographic studies of proteins. Amino acid side chains often cannot be reliably identified from the electron density. Many protein crystal structures that are now being solved are simple variants of a known wild-type structure. Thus, cloning artifacts or other untoward events can readily lead to cases in which the proposed sequence is not correct. An example is presented showing that mass spectrometry provides an excellent tool for analyzing suspected errors. The X-ray crystal structure of an insertion mutant of Staphylococcal nuclease has been solved to 1.67 A resolution and refined to a crystallographic R value of 0.170. A single residue has been inserted in the C-terminal α helix. The inserted amino acid was believed to be an alanine residue, but the final electron density maps strongly indicated that a glycine had been inserted instead. To confirm the observations from the X-ray data, matrix-assisted laser desorption mass spectrometry was employed to verify the glycine insertion. This mass spectrometric technique has sufficient mass accuracy to detect the methyl group that distinguishes glycine from alanine and can be extended to the more common situation in which crystallographic measurements suggest a problem with the sequence, but cannot pinpoint its location or nature. (orig.)

  3. Resolution of a protein sequence ambiguity by X-ray crystallographic and mass spectrometric methods

    Energy Technology Data Exchange (ETDEWEB)

    Keefe, L.J.; Lattman, E.E. (Dept. of Biophysics and Biophysical Chemistry, Johns Hopkins Univ. School of Medicine, Baltimore, MD (United States)); Wolkow, C.; Woods, A.; Chevrier, M.; Cotter, R.J. (Middle Atlantic Mass Spectrometry Lab., Johns Hopkins Univ. School of Medicine, Baltimore, MD (United States))

    1992-04-01

    Ambiguities in amino acid sequences are a potential problem in X-ray crystallographic studies of proteins. Amino acid side chains often cannot be reliably identified from the electron density. Many protein crystal structures that are now being solved are simple variants of a known wild-type structure. Thus, cloning artifacts or other untoward events can readily lead to cases in which the proposed sequence is not correct. An example is presented showing that mass spectrometry provides an excellent tool for analyzing suspected errors. The X-ray crystal structure of an insertion mutant of Staphylococcal nuclease has been solved to 1.67 A resolution and refined to a crystallographic R value of 0.170. A single residue has been inserted in the C-terminal {alpha} helix. The inserted amino acid was believed to be an alanine residue, but the final electron density maps strongly indicated that a glycine had been inserted instead. To confirm the observations from the X-ray data, matrix-assisted laser desorption mass spectrometry was employed to verify the glycine insertion. This mass spectrometric technique has sufficient mass accuracy to detect the methyl group that distinguishes glycine from alanine and can be extended to the more common situation in which crystallographic measurements suggest a problem with the sequence, but cannot pinpoint its location or nature. (orig.).

  4. Mass-spectrometric analysis of trace oxygen in carbon dioxide; Analyse de traces d'oxygene dans le gaz carbonique par spectrometrie de masse

    Energy Technology Data Exchange (ETDEWEB)

    Nief, G; Severin, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    The mass spectrum of pure CO{sub 2} contains a peak of weight 32 whose relationship to peak at 44 varies greatly depending on the previous history of the source of ions and even during the course of an analysis. The fact that this peak is more or less proportional to the pressure and that its appearance potential is the same as that of oxygen leads us to suppose that it is produced from oxygen formed by dissociation of the carbon dioxide on the tungsten filament. A prior treatment of the ion source with acetylene reduces the ratio 32/44 to a value of about 15.10{sup -5}. This same treatment also stabilises the spectrometer's sensitivity to oxygen. Two lines of introduction enable pure carbon dioxide, the specimen to be estimated and a reference mixture of known oxygen content to be sent into the mass spectrometer in quick succession. Oxygen in the carbon dioxide in amounts ranging between 0 and 500 p.p.m. can thus be determined to an accuracy of {+-} 5 p.p.m., the analysis taking 30 minutes. (author) [French] Le spectre de masse de CO{sub 2} pur contient un pic de masse 32 dont le rapport au pic 44 varie enormement suivant l'histoire anterieure de la source d'ions et meme au cours d'une analyse. Le fait que ce pic soit grossierement proportionnel a la pression et que son potentiel d'apparition soit le meme que celui de l'oxygene permet de supposer qu'il est engendre a partir de l'oxygene produit par dissociation du gaz carbonique sur le filament de tungstene. Un conditionnement prealable de la source d'ions avec de l'acetylene reduit le rapport 32/44 a une valeur d'environ 15.10{sup -5}. Ce meme traitement stabilise egalement la sensibilite du spectrometre vis-a-vis de l'oxygene. Une double ligne d'introduction de gaz permet d'envoyer en successions rapides dans le spectrometre de masse le gaz carbonique pur, l'echantillon a doser et un melange de reference de teneur en oxygene connue. On arrive ainsi a doser l'oxygene dans le gaz carbonique dans la gamme de 0 a

  5. An automated multidimensional preparative gas chromatographic system for isolation and enrichment of trace amounts of xenon from ambient air.

    Science.gov (United States)

    Larson, Tuula; Östman, Conny; Colmsjö, Anders

    2011-04-01

    The monitoring of radioactive xenon isotopes is one of the principal methods for the detection of nuclear explosions in order to identify clandestine nuclear testing. In this work, a miniaturized, multiple-oven, six-column, preparative gas chromatograph was constructed in order to isolate trace quantities of radioactive xenon isotopes from ambient air, utilizing nitrogen as the carrier gas. The multidimensional chromatograph comprised preparative stainless steel columns packed with molecular sieves, activated carbon, and synthetic carbon adsorbents (e.g., Anasorb®-747 and Carbosphere®). A combination of purification techniques--ambient adsorption, thermal desorption, back-flushing, thermal focusing, and heart cutting--was selectively optimized to produce a well-defined xenon peak that facilitated reproducible heart cutting and accurate quantification. The chromatographic purification of a sample requires approximately 4 h and provides complete separation of xenon from potentially interfering components (such as water vapor, methane, carbon dioxide, and radon) with recovery and accuracy close to 100%. The preparative enrichment process isolates and concentrates a highly purified xenon gas fraction that is suitable for subsequent ultra-low-level γ-, ß/γ-spectroscopic or high-resolution mass spectrometric measurement (e.g., to monitor the gaseous fission products of nuclear explosions at remote locations). The Xenon Processing Unit is a free-standing, relatively lightweight, and transportable system that can be interfaced to a variety of sampling and detection systems. It has a relatively inexpensive, rugged, and compact modular (19-inch rack) design that provides easy access to all parts for maintenance and has a low power requirement.

  6. Mass spectrometric analysis of EPO IEF-PAGE interfering substances in nitrile examination gloves.

    Science.gov (United States)

    Reichel, Christian

    2012-10-01

    Direct detection of doping with recombinant erythropoietins (rhEPO) is accomplished by isoelectric focusing (IEF) or sodium dodecylsulfate (SDS) polyacrylamide gel electrophoresis (PAGE). In a recent publication, Lasne et al. (Electrophoresis 2011, 32, 1444) showed that improper use of nitrile examination gloves during sample collection, sample preparation, and IEF-PAGE may lead to distorted or absent EPO IEF-profiles. In order to clarify which substances are responsible for this observation, a mass spectrometric study on water extractable compounds found in nitrile gloves was performed. Several substance classes were shown to be present, among them polyethylene glycols (PEG), anionic and nonionic surfactants, as well as alcohol ethoxylates and plasticizers. It could be demonstrated that alkylbenzenesulfonates, the main category of detectable anionic detergents, and among them sodium dodecylbenzenesulfonate (SDBS) and its homologs, are the prime reason for the interference of nitrile gloves with EPO IEF-PAGE. Copyright © 2012 John Wiley & Sons, Ltd.

  7. Analysis of carbonyl compounds via headspace solid-phase microextraction with on-fiber derivatization and gas chromatographic-ion trap tandem mass spectrometric determination of their O-(2,3,4,5,6-pentafluorobenzyl)oxime derivatives

    Energy Technology Data Exchange (ETDEWEB)

    Schmarr, Hans-Georg [Dienstleistungszentrum Laendlicher Raum (DLR) Rheinpfalz, Breitenweg 71, D-67435 Neustadt an der Weinstrasse (Germany)], E-mail: hans-georg.schmarr@dlr.rlp.de; Potouridis, Theodoros; Ganss, Sebastian; Sang, Wei; Koepp, Benedikt; Bokuz, Ursula; Fischer, Ulrich [Dienstleistungszentrum Laendlicher Raum (DLR) Rheinpfalz, Breitenweg 71, D-67435 Neustadt an der Weinstrasse (Germany)

    2008-06-09

    An improved method for the analysis of carbonyls is described utilizing a headspace solid-phase microextraction (HS-SPME) step and on-fiber derivatization with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBHA) hydrochloride. Thermal desorption of the oxime derivatives formed on the fiber is followed by gas chromatographic separation coupled to an ion trap tandem mass spectrometer (GC-ITMS). Selecting specific fragment ions within the electron ionization (EI{sup +}) mass spectra of these oxime derivatives as precursor ions for MS-MS fragmentation provides a suitable method for the target analysis of individual carbonyl classes, such as alkanals, (E)-2-alkenals, (E,E)-2,4-alkadienals, and others. Retention indices on polar as well as on apolar stationary phases along with EI{sup +} mass spectra patterns are presented for a large set of oxime derivatives, giving valuable information needed for unambiguous assignment of substances in complex sample matrices. The fast sample preparation and derivatization step via HS-SPME can be automated and is applicable to a variety of biological samples and foodstuffs, allowing rapid and sensitive screening analyses of important aldehydic biomarkers and aroma active compounds.

  8. Standard test methods for chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade plutonium dioxide powders and pellets

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 These test methods cover procedures for the chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade plutonium dioxide powders and pellets to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Plutonium Sample Handling 8 to 10 Plutonium by Controlled-Potential Coulometry Plutonium by Ceric Sulfate Titration Plutonium by Amperometric Titration with Iron(II) Plutonium by Diode Array Spectrophotometry Nitrogen by Distillation Spectrophotometry Using Nessler Reagent 11 to 18 Carbon (Total) by Direct Combustion–Thermal Conductivity 19 to 30 Total Chlorine and Fluorine by Pyrohydrolysis 31 to 38 Sulfur by Distillation Spectrophotometry 39 to 47 Plutonium Isotopic Analysis by Mass Spectrometry Rare Earth Elements by Spectroscopy 48 to 55 Trace Elements by Carrier–Distillation Spectroscopy 56 to 63 Impurities by ICP-AES Impurity Elements by Spark-Source Mass Spectrography 64 to 70 Moisture by the Coulomet...

  9. Methods of direct (non-chromatographic) quantification of body metabolites utilizing chemical ionization mass spectrometry

    International Nuclear Information System (INIS)

    Mee, J.M.L.

    1978-01-01

    For quantitative determination of known metabolites from the biological sample by direct chemical ionization mass spectrometry (CI-MS), the method of internal standard using stable isotopically labelled analogs appears to be the method of choice. In the case where stable isotope ratio determinations could not be applied, and alternative quantification can be achieved using non-labelled external or internal standards and a calibration curve (sum of peak height per a given number of scans versus concentration). The technique of computer monitoring permits display and plotting of ion current profiles (TIC and SIC) or spectra per a given number of scans or a given range of mass per charge. Examples are given in areas of clinical application and the quantitative data show very good agreement with the conventional chromatographic measurements. (Auth.)

  10. Analysis of hairy root culture of Rauvolfia serpentina using direct analysis in real time mass spectrometric technique.

    Science.gov (United States)

    Madhusudanan, K P; Banerjee, Suchitra; Khanuja, Suman P S; Chattopadhyay, Sunil K

    2008-06-01

    The applicability of a new mass spectrometric technique, DART (direct analysis in real time) has been studied in the analysis of the hairy root culture of Rauvolfia serpentina. The intact hairy roots were analyzed by holding them in the gap between the DART source and the mass spectrometer for measurements. Two nitrogen-containing compounds, vomilenine and reserpine, were characterized from the analysis of the hairy roots almost instantaneously. The confirmation of the structures of the identified compounds was made through their accurate molecular formula determinations. This is the first report of the application of DART technique for the characterization of compounds that are expressed in the hairy root cultures of Rauvolfia serpentina. Moreover, this also constitutes the first report of expression of reserpine in the hairy root culture of Rauvolfia serpentina. Copyright (c) 2008 John Wiley & Sons, Ltd.

  11. Mass spectrometric identification of proteins that interact through specific domains of the poly(A) binding protein.

    Science.gov (United States)

    Richardson, Roy; Denis, Clyde L; Zhang, Chongxu; Nielsen, Maria E O; Chiang, Yueh-Chin; Kierkegaard, Morten; Wang, Xin; Lee, Darren J; Andersen, Jens S; Yao, Gang

    2012-09-01

    Poly(A) binding protein (PAB1) is involved in a number of RNA metabolic functions in eukaryotic cells and correspondingly is suggested to associate with a number of proteins. We have used mass spectrometric analysis to identify 55 non-ribosomal proteins that specifically interact with PAB1 from Saccharomyces cerevisiae. Because many of these factors may associate only indirectly with PAB1 by being components of the PAB1-mRNP structure, we additionally conducted mass spectrometric analyses on seven metabolically defined PAB1 deletion derivatives to delimit the interactions between these proteins and PAB1. These latter analyses identified 13 proteins whose associations with PAB1 were reduced by deleting one or another of PAB1's defined domains. Included in this list of 13 proteins were the translation initiation factors eIF4G1 and eIF4G2, translation termination factor eRF3, and PBP2, all of whose previously known direct interactions with specific PAB1 domains were either confirmed, delimited, or extended. The remaining nine proteins that interacted through a specific PAB1 domain were CBF5, SLF1, UPF1, CBC1, SSD1, NOP77, yGR250c, NAB6, and GBP2. In further study, UPF1, involved in nonsense-mediated decay, was confirmed to interact with PAB1 through the RRM1 domain. We additionally established that while the RRM1 domain of PAB1 was required for UPF1-induced acceleration of deadenylation during nonsense-mediated decay, it was not required for the more critical step of acceleration of mRNA decapping. These results begin to identify the proteins most likely to interact with PAB1 and the domains of PAB1 through which these contacts are made.

  12. Mass spectrometric determination of burnup of thorium-uranium dioxide fuel

    International Nuclear Information System (INIS)

    Green, L.W.; Knight, C.H.; Longhurst, T.H.; Cassidy, R.M.

    1984-01-01

    The isotopes 148 Nd and 145+146 Nd were investigated for use as fission monitors. A two-column anion-exchange procedure was used to separate these and U and Th from the fuel matrix, and the purified fractions were analyzed by thermal ionization mass spectrometry. Relative standard deviations of Nd, U, and Th determinations by isotope dilution were ∼0.7%. A computer-generated simulation of the irradiation was used to estimate the effective fission yields for 148 Nd and 145+146 Nd. Burnup results with 145+146 Nd as the fission monitor showed excellent agreement with results obtained by a high-performance liquid chromatographic method that used 139 La as the fission monitor; the average difference between the two methods was 0.02%. The 148 Nd results were biased high by up to 4%; this was attributed to a 147 Nd neutron capture effect. Results obtained with the initial heavy element content estimated from the weight and initial composition of the fuel, instead of from analyses for the actinides, showed excellent agreement (average difference = 0.2 %) with the conventional method. (author)

  13. Determination of C6-C10 aromatic hydrocarbons in water by purge-and-trap capillary gas chromatography

    Science.gov (United States)

    Eganhouse, R.P.; Dorsey, T.F.; Phinney, C.S.; Westcott, A.M.

    1993-01-01

    A method is described for the determination of the C6-C10 aromatic hydrocarbons in water based on purge-and-trap capillary gas chromatography with flame ionization and mass spectrometric detection. Retention time data and 70 eV mass spectra were obtained for benzene and all 35 C7-C10 aromatic hydrocarbons. With optimized chromatographic conditions and mass spectrometric detection, benzene and 33 of the 35 alkylbenzenes can be identified and measured in a 45-min run. Use of a flame ionization detector permits the simultaneous determination of benzene and 26 alkylbenzenes.

  14. Application and evaluation of the mass spectrometric isotope dilution technique in the determination of rare earths in geological materials

    International Nuclear Information System (INIS)

    Moraes, N.M.P. de.

    1988-01-01

    Establishment of the experimental procedures employed in the rare earth element determination of geological samples by mass spectrometric isotope dilution analysis is discussed in the present work. The procedures involve preparation and calibration of the isotope tracers isotope dilution, dissolution in a teflon pressure vessel, chemical separation and isotope analysis using a fully automated Micromass VG ISOTOPES model 354 thermal ionization mass spectrometer. For the initial chemical separation of total rare earths the cationic resin was employed and HC1 and HNO 3 acids as eluents. In the second step rare earths elements were separated into individual (La, Ce and Nd) and subgroups (Sm-Eu-Gd, Yb-Er-Dy) fractions using the same cationic resin and α-HIBA as eluent. Nine elements La, Ce, Nd, Sm, Eu, Gd, Dy, Er and Yb are determined by this method in the ''United States Geological Survey'' (USGS) standard samples GSP-1, AGV-1 and G-2, with an overall precision of +- 1 to 2% and an accuracy of 5%. The concentration of rare earth element determined in the standard sample PCC-1 showed that the total analytical blanks are in submicrogram levels. The concentration of rare earth elements in the same USGS standard samples were also determined by Instrumental neutron activation analysis, neutron activation analysis with chemical separation before irradiation and inductively coupled argon plasma spectroscopy. The chemical procedures employed for these methods are the same as that used for mass spectrometric isotope dilution. Based on the results obtained, each method was evaluated pointing out their merits and defects. The study clearly showed that the chemical procedure employed for all these techniques was satisfactory. (author) [pt

  15. Analysis of Endocrine Disrupting Pesticides by Capillary GC with Mass Spectrometric Detection

    Directory of Open Access Journals (Sweden)

    Svetlana Hrouzková

    2012-09-01

    Full Text Available Endocrine disrupting chemicals, among them many pesticides, alter the normal functioning of the endocrine system of both wildlife and humans at very low concentration levels. Therefore, the importance of method development for their analysis in food and the environment is increasing. This also covers contributions in the field of ultra-trace analysis of multicomponent mixtures of organic pollutants in complex matrices. With this fact conventional capillary gas chromatography (CGC and fast CGC with mass spectrometric detection (MS has acquired a real importance in the analysis of endocrine disrupting pesticide (EDP residues. This paper provides an overview of GC methods, including sample preparation steps, for analysis of EDPs in a variety of matrices at ultra-trace concentration levels. Emphasis is put on separation method, mode of MS detection and ionization and obtained limits of detection and quantification. Analysis time is one of the most important aspects that should be considered in the choice of analytical methods for routine analysis. Therefore, the benefits of developed fast GC methods are important.

  16. Dansyl-peptides matrix-assisted laser desorption/ionization mass spectrometric (MALDI-MS) and tandem mass spectrometric (MS/MS) features improve the liquid chromatography/MALDI-MS/MS analysis of the proteome.

    Science.gov (United States)

    Chiappetta, Giovanni; Ndiaye, Sega; Demey, Emmanuelle; Haddad, Iman; Marino, Gennaro; Amoresano, Angela; Vinh, Joëlle

    2010-10-30

    Peptide tagging is a useful tool to improve matrix-assisted laser desorption/ionization tandem mass spectrometric (MALDI-MS/MS) analysis. We present a new application of the use of the dansyl chloride (DNS-Cl). DNS-Cl is a specific primary amine reagent widely used in protein biochemistry. It adds a fluorescent dimethylaminonaphthalene moiety to the molecule. The evaluation of MALDI-MS and MS/MS analyses of dansylated peptides shows that dansylation raises the ionization efficiency of the most hydrophilic species compared with the most hydrophobic ones. Consequently, higher Mascot scores and protein sequence coverage are obtained by combining MS and MS/MS data of native and tagged samples. The N-terminal DNS-Cl sulfonation improves the peptide fragmentation and promotes the generation of b-fragments allowing better peptide sequencing. In addition, we set up a labeling protocol based on the microwave chemistry. Peptide dansylation proved to be a rapid and cheap method to improve the performance of liquid chromatography (LC)/MALDI-MS/MS analysis at the proteomic scale in terms of peptide detection and sequence coverage. Copyright © 2010 John Wiley & Sons, Ltd.

  17. Identification of organic sulfur compounds in coal bitumen obtained by different extraction techniques using comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometric detection

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Maria Elisabete; Cappelli Fontanive, Fernando; Bastos Caramao, Elina; Alcaraz Zini, Claudia [Universidade Federal do Rio Grande do Sul, Instituto de Quimica, Porto Alegre, RS (Brazil); Oliveira, Jose Vladimir de [URI, Universidade Regional Integrada do Alto Uruguai e das Missoes, Erechim, RS (Brazil)

    2011-11-15

    The determination of organic sulfur compounds (OSC) in coal is of great interest. Technically and operationally these compounds are not easily removed and promote corrosion of equipment. Environmentally, the burning of sulfur compounds leads to the emission of SO{sub x} gases, which are major contributors to acid rain. Health-wise, it is well known that these compounds have mutagenic and carcinogenic properties. Bitumen can be extracted from coal by different techniques, and use of gas chromatography coupled to mass spectrometric detection enables identification of compounds present in coal extracts. The OSC from three different bitumens were tentatively identified by use of three different extraction techniques: accelerated solvent extraction (ASE), ultrasonic extraction (UE), and supercritical-fluid extraction (SFE). Results obtained from one-dimensional gas chromatography (1D GC) coupled to quadrupole mass spectrometric detection (GC-qMS) and from two-dimensional gas chromatography with time-of-flight mass spectrometric detection (GC x GC-TOFMS) were compared. By use of 2D GC, a greater number of OSC were found in ASE bitumen than in SFE and UE bitumens. No OSC were identified with 1D GC-qMS, although some benzothiophenes and dibenzothiophenes were detected by use of EIM and SIM modes. GC x GC-TOFMS applied to investigation of OSC in bitumens resulted in analytical improvement, as more OSC classes and compounds were identified (thiols, sulfides, thiophenes, naphthothiophenes, benzothiophenes, and benzonaphthothiophenes). The roof-tile effect was observed for OSC and PAH in all bitumens. Several co-elutions among analytes and with matrix interferents were solved by use of GC x GC. (orig.)

  18. Standard test methods for chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade mixed oxides ((U, Pu)O2)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 These test methods cover procedures for the chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade mixed oxides, (U, Pu)O2, powders and pellets to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Uranium in the Presence of Pu by Potentiometric Titration Plutonium by Controlled-Potential Coulometry Plutonium by Amperometric Titration with Iron (II) Nitrogen by Distillation Spectrophotometry Using Nessler Reagent 7 to 14 Carbon (Total) by Direct Combustion-Thermal Conductivity 15 to 26 Total Chlorine and Fluorine by Pyrohydrolysis 27 to 34 Sulfur by Distillation-Spectrophotometry 35 to 43 Moisture by the Coulometric, Electrolytic Moisture Analyzer 44 to 51 Isotopic Composition by Mass Spectrometry Rare Earths by Copper Spark Spectroscopy 52 to 59 Trace Impurities by Carrier Distillation Spectroscopy 60 to 69 Impurities by Spark-Source Mass Spectrography 70 to 76 Total Gas in Reactor-Grade Mixed Dioxide P...

  19. Liquid chromatography-mass spectrometry in forensic toxicology.

    Science.gov (United States)

    Van Bocxlaer, J F; Clauwaert, K M; Lambert, W E; Deforce, D L; Van den Eeckhout, E G; De Leenheer, A P

    2000-01-01

    Liquid chromatography-mass spectrometry has evolved from a topic of mainly research interest into a routinely usable tool in various application fields. With the advent of new ionization approaches, especially atmospheric pressure, the technique has established itself firmly in many areas of research. Although many applications prove that LC-MS is a valuable complementary analytical tool to GC-MS and has the potential to largely extend the application field of mass spectrometry to hitherto "MS-phobic" molecules, we must recognize that the use of LC-MS in forensic toxicology remains relatively rare. This rarity is all the more surprising because forensic toxicologists find themselves often confronted with the daunting task of actually searching for evidence materials on a scientific basis without any indication of the direction in which to search. Through the years, mass spectrometry, mainly in the GC-MS form, has gained a leading role in the way such quandaries are tackled. The advent of robust, bioanalytically compatible combinations of liquid chromatographic separation with mass spectrometric detection really opens new perspectives in terms of mass spectrometric identification of difficult molecules (e.g., polar metabolites) or biopolymers with toxicological relevance, high throughput, and versatility. Of course, analytical toxicologists are generally mass spectrometry users rather than mass spectrometrists, and this difference certainly explains the slow start of LC-MS in this field. Nevertheless, some valuable applications have been published, and it seems that the introduction of the more universal atmospheric pressure ionization interfaces really has boosted interests. This review presents an overview of what has been realized in forensic toxicological LC-MS. After a short introduction into LC-MS interfacing operational characteristics (or limitations), it covers applications that range from illicit drugs to often abused prescription medicines and some

  20. Tropical Journal of Pharmaceutical Research - Vol 14, No 1 (2015)

    African Journals Online (AJOL)

    Larvicidal Activity of Essential Oil Derived from Illicium henryi Diels (Illiciaceae) ... on the Stability of Soybean Oil · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT ... Gas Chromatographic-Mass Spectrometric Analysis of Essential Oil of ...

  1. Detection, characterization and quantification of salicylic acid conjugates in plant extracts by ESI tandem mass spectrometric techniques.

    Science.gov (United States)

    Pastor, Victoria; Vicent, Cristian; Cerezo, Miguel; Mauch-Mani, Brigitte; Dean, John; Flors, Victor

    2012-04-01

    An approach for the detection and characterization of SA derivatives in plant samples is presented based on liquid chromatography coupled to electrospray ionization (ESI) tandem mass spectrometric techniques. Precursor ion scan methods using an ESI triple quadrupole spectrometer for samples from plants challenged with the virulent Pseudomonas syringae pv tomato DC3000 allowed us to detect two potential SA derivatives. The criterion used to consider a potential SA derivative is based on the detection of analytes in the precursor ion scan chromatogram upon selecting m/z 137 and m/z 93 that correspond to the salicylate and its main product ion, respectively. Product ion spectra of the newly-detected analytes as well as accurate m/z determinations using an ESI Q-time-of-flight instrument were registered as means of characterization and strongly suggest that glucosylated forms of SA at the carboxylic and at the phenol functional groups are present in plant samples. The specific synthesis and subsequent chromatography of salicylic glucosyl ester (SGE) and glucosyl salicylate (SAG) standards confirmed the chemical identity of both peaks that were obtained applying different tandem mass spectrometric techniques and accurate m/z determinations. A multiple reaction monitoring method has been developed and applied to plant samples. The advantages of this LC-ESI-MS/MS methods with respect to the traditional analysis of glucosyl conjugates are also discussed. Preliminary results revealed that SA and the glucosyl conjugates are accumulated in Arabidopsis thaliana in a time dependent manner, accordingly to the up-regulation of SA-dependent defenses following P. syringae infection. This technique applied to plant hormones or fragment ions may be useful to obtain chemical family members of plant metabolites and help identify their contribution in the signaling of plant defenses. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  2. Alkylation of human serum albumin by sulfur mustard in vitro and in vivo : Mass spectrometric analysis of a cysteine adduct as a sensitive biomarker of exposure

    NARCIS (Netherlands)

    Noort, D.; Hulst, A.G.; Jong, L.P.A. de; Benschop, H.P.

    1999-01-01

    To develop a mass spectrometric assay for the detection of sulfur mustard adducts with human serum albumin, the following steps were performed: quantitation of the binding of the agent to the protein by using [14C] sulfur mustard and analysis of acidic and tryptic digests of albumin from blood after

  3. Mass spectrometric determination of burnup of thorium-uranium dioxide fuel

    Energy Technology Data Exchange (ETDEWEB)

    Green, L.W.; Knight, C.H.; Longhurst, T.H.; Cassidy, R.M

    1984-07-01

    The isotopes {sup 148}Nd and {sup 145+146}Nd were investigated for use as fission monitors. A two-column anion-exchange procedure was used to separate these and U and Th from the fuel matrix, and the purified fractions were analyzed by thermal ionization mass spectrometry. Relative standard deviations of Nd, U, and Th determinations by isotope dilution were {approx}0.7%. A computer-generated simulation of the irradiation was used to estimate the effective fission yields for {sup 148}Nd and {sup 145+146}Nd. Burnup results with {sup 145+146}Nd as the fission monitor showed excellent agreement with results obtained by a high-performance liquid chromatographic method that used {sup 139}La as the fission monitor; the average difference between the two methods was 0.02%. The {sup 148}Nd results were biased high by up to 4%; this was attributed to a {sup 147}Nd neutron capture effect. Results obtained with the initial heavy element content estimated from the weight and initial composition of the fuel, instead of from analyses for the actinides, showed excellent agreement (average difference = 0.2 %) with the conventional method. (author)

  4. Determination of deuterium in metal by vacuum fusion-mass spectrometric method

    International Nuclear Information System (INIS)

    Wada, Yukio; Akiyama, Shigeo; Ochiai, Ken-ichi; Asakura, Toshiro; Tsutsumi, Ken-ichi

    1976-01-01

    A specimen of deuterium-enriched Zircaloy was prepared to study a method for the determination of deuterium in metal. The measuring apparatus consists of vacuum fusion section (10 -5 -10 -4 Torr), gas extracting and collecting section, the section of introducing both standard D 2 and HD gases into a gas holder, and mass spectrometric analysis section. The deuterium in Zircaloy can be extracted by 100% for 5 min. at 1600 0 C. The main components of the extracted gas are H 2 , D 2 , HD, CO, H 2 O and N 2 . Deuterium is determined by the calculation from the determinations of D 2 and HD. The amounts of D 2 and HD gases in the specimen were obtained from the calibration curve prepared and the spectrum intensity of D 2 + and HD + resulted from specimen analysis. As a result of the analysis of D 2 -enriched Zircaloy, it has been found that the precision of the determination is within the coefficient variation of about 3% for the extracted D 2 gas amount of 10 -3 -10 -2 ml (STP), including the deuterium segregation in the specimen, and the determination limit was 1 x 10 -5 ml (STP). (Kobatake, H.)

  5. Absolute analysis of uranium isotopic concentrations with a gas ion source mass spectrometer; Analyses absolues des concentrations isotopiques de l'uranium par spectrometre de masse equipe d'une source a gaz

    Energy Technology Data Exchange (ETDEWEB)

    Chaussy, L.; Boyer, R. [Commissariat a l' Energie Atomique, Pierrelatte (France)

    1969-07-01

    Mass spectrometer with electronic bombardment ions source for routine uranium isotopic analysis are used like relative measurements apparatus. We show that such mass spectrometers can be used for absolute measurements with a very high sensitivity and precision which are ten times better than theses of thermo-ionic ions source mass spectrometer. We examine the causes of systematic errors and we give experimental data. In particular natural uranium sample used as reference give: U{sub 5} = 0.7202 {+-} 0.0005 atoms per cent; U{sub 4} = 0.00552 {+-} 0.0003 atoms per cent. The use of this method is justified for standards control. (authors) [French] Les spectrometres de masse a source par bombardement electronique pour l'analyse de l'uranium sous forme d'hexafluorure, sont utilises en routine comme des appareils de mesure relative. On montre que l'on peut utiliser de tels appareils pour effectuer des mesures absolues avec une excellente sensibilite et reproductibilite, dix fois superieure a celle des spectrometres a source thermoionique. On examine en detail les causes d'erreurs systematiques et on donne des resultats experimentaux. En particulier, l'analyse d'un echantillon d'uranium naturel donne: U{sub 5} = 0.7202 {+-} 0.0005 atomes pour cent; U{sub 4} = 0.00552 {+-} 0.0003 atomes pour cent. La technique de mesure est utile pour le controle d'etalons isotopiques. (auteurs)

  6. Mass spectrometry in oceanography

    International Nuclear Information System (INIS)

    Aggarwal, Suresh K.

    2000-01-01

    Mass spectrometry plays an important role in oceanography for various applications. Different types of inorganic as well as organic mass spectrometric techniques are being exploited world-wide to understand the different aspects of marine science, for palaeogeography, palaeoclimatology and palaeoecology, for isotopic composition and concentrations of different elements as well as for speciation studies. The present paper reviews some of the applications of atomic mass spectrometric techniques in the area of oceanography

  7. Electronic states and nature of bonding in the molecule YC by all electron ab initio multiconfiguration self-consistent-field calculations and mass spectrometric equilibrium experiments

    DEFF Research Database (Denmark)

    Shim, Irene; Pelino, Mario; Gingerich, Karl A.

    1992-01-01

    , and they hardly contribute to the bonding. The chemical bond in the YC molecule is polar with charge transfer from Y to C giving rise to a dipole moment of 3.90 D at 3.9 a.u. in the 4PI ground state. Mass spectrometric equilibrium investigations in the temperature range 2365-2792 K have resulted...

  8. Gas chromatographic/mass spectrometric and microbiological analyses on irradiated chicken

    Science.gov (United States)

    Parlato, A.; Calderaro, E.; Bartolotta, A.; D'Oca, M. C.; Giuffrida, S. A.; Brai, M.; Tranchina, L.; Agozzino, P.; Avellone, G.; Ferrugia, M.; Di Noto, A. M.; Caracappa, S.

    2007-08-01

    Ionizing radiation is widely used as treatment technique for food preservation. It involves among others reduction of microbial contamination, disinfestations, sprout inhibition and extension of shelf life of food. However, the commercialization of irradiated food requires the availability of reliable methods to identify irradiated foodstuffs. In this paper, we present results on the application to irradiated chicken of this method, based on the detection, in muscle and skin samples, of the peaks of ions 98 Da and 112 Da, in a ratio approximately 4:1, typical of radiation induced 2-dodecylcyclobutanones (2-DCB). Aim of the work was also to study the time stability of the measured parameters in samples irradiated at 3 and 5 kGy, and to verify the efficacy of the treatment from a microbiological point of view. Our results show that, one month after irradiation at 3 kGy, the method is suitable using the skin but not the muscle, while the measured parameters are detectable in both samples irradiated at 5 kGy. The microbial population was substantially reduced even at 3 kGy.

  9. Gas chromatographic/mass spectrometric and microbiological analyses on irradiated chicken

    Energy Technology Data Exchange (ETDEWEB)

    Parlato, A. [Dipartimento di Ingegneria Nucleare, Universita di Palermo, Viale delle Scienze, Edificio 6, 90100 Palermo (Italy); Calderaro, E. [Dipartimento di Ingegneria Nucleare, Universita di Palermo, Viale delle Scienze, Edificio 6, 90100 Palermo (Italy); Bartolotta, A. [Dipartimento Farmacochimico, Tossicologico e Biologico, Universita di Palermo, via Archirafi 32, 90123 Palermo (Italy)]. E-mail: antonio.bartolotta@unipa.it; D' Oca, M.C. [Dipartimento Farmacochimico, Tossicologico e Biologico, Universita di Palermo, via Archirafi 32, 90123 Palermo (Italy); Giuffrida, S.A. [Dipartimento Farmacochimico, Tossicologico e Biologico, Universita di Palermo, via Archirafi 32, 90123 Palermo (Italy); Brai, M. [Dipartimento di Fisica e Tecnologie Relative, Universita di Palermo, Viale delle Scienze, Edificio 18, 90100 Palermo (Italy); Tranchina, L. [Dipartimento di Fisica e Tecnologie Relative, Universita di Palermo, Viale delle Scienze, Edificio 18, 90100 Palermo (Italy); Agozzino, P. [Dipartimento di Chimica e Tecnologie Farmaceutiche, Universita di Palermo, via Archirafi 32, 90123 Palermo (Italy); Avellone, G. [Dipartimento di Chimica e Tecnologie Farmaceutiche, Universita di Palermo, via Archirafi 32, 90123 Palermo (Italy); Ferrugia, M. [Dipartimento di Chimica e Tecnologie Farmaceutiche, Universita di Palermo, via Archirafi 32, 90123 Palermo (Italy); Di Noto, A.M. [Istituto Zooprofilattico Sperimentale della Sicilia ' A.Mirri' , Palermo (Italy); Caracappa, S. [Istituto Zooprofilattico Sperimentale della Sicilia ' A.Mirri' , Palermo (Italy)

    2007-08-15

    Ionizing radiation is widely used as treatment technique for food preservation. It involves among others reduction of microbial contamination, disinfestations, sprout inhibition and extension of shelf life of food. However, the commercialization of irradiated food requires the availability of reliable methods to identify irradiated foodstuffs. In this paper, we present results on the application to irradiated chicken of this method, based on the detection, in muscle and skin samples, of the peaks of ions 98 Da and 112 Da, in a ratio approximately 4:1, typical of radiation induced 2-dodecylcyclobutanones (2-DCB). Aim of the work was also to study the time stability of the measured parameters in samples irradiated at 3 and 5 kGy, and to verify the efficacy of the treatment from a microbiological point of view. Our results show that, one month after irradiation at 3 kGy, the method is suitable using the skin but not the muscle, while the measured parameters are detectable in both samples irradiated at 5 kGy. The microbial population was substantially reduced even at 3 kGy.

  10. Gas chromatographic/mass spectrometric and microbiological analyses on irradiated chicken

    International Nuclear Information System (INIS)

    Parlato, A.; Calderaro, E.; Bartolotta, A.; D'Oca, M.C.; Giuffrida, S.A.; Brai, M.; Tranchina, L.; Agozzino, P.; Avellone, G.; Ferrugia, M.; Di Noto, A.M.; Caracappa, S.

    2007-01-01

    Ionizing radiation is widely used as treatment technique for food preservation. It involves among others reduction of microbial contamination, disinfestations, sprout inhibition and extension of shelf life of food. However, the commercialization of irradiated food requires the availability of reliable methods to identify irradiated foodstuffs. In this paper, we present results on the application to irradiated chicken of this method, based on the detection, in muscle and skin samples, of the peaks of ions 98 Da and 112 Da, in a ratio approximately 4:1, typical of radiation induced 2-dodecylcyclobutanones (2-DCB). Aim of the work was also to study the time stability of the measured parameters in samples irradiated at 3 and 5 kGy, and to verify the efficacy of the treatment from a microbiological point of view. Our results show that, one month after irradiation at 3 kGy, the method is suitable using the skin but not the muscle, while the measured parameters are detectable in both samples irradiated at 5 kGy. The microbial population was substantially reduced even at 3 kGy

  11. Domestic Preparedness Program: Evaluation of the Agilent Gas Chromatograph - Flame Photometric Detector/Mass Selective Detector (GC-FPD/MSD) System Against Chemical Warfare Agents Summary Report

    National Research Council Canada - National Science Library

    Longworth, Terri

    2003-01-01

    This report characterizes the chemical warfare agent (CWA) detection potential of the commercially available Agilent gas chromatograph-flame photometric detector/mass selective detector (GC-FPD/MSD...

  12. Analysis of solids by spark-source mass spectrometry; Analyse des solides au spectrometre de masse a etincelles

    Energy Technology Data Exchange (ETDEWEB)

    Stefani, R; Desjardins, M; Brun, J C; Cornu, A; Bourguillot, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-07-01

    Spark source mass spectrometer MS7 has been designed to determine traces of impurities in solids without standards. An atlas of 12 000 lines, assembled in the Grenoble laboratory, allows a quick investigation of mass spectra, notwithstanding their complexity due to multiply charged and polyatomic darkening. Photometric measurements increase accuracy calibration curve is known for each photo-plate. Further, reproducibility is better, if random fluctuations of matrix line darkening are corrected. So far, in a concentration range of 0,01 to 1 000 ppm (atomic), reproducibility is approximately 20 per cent, but absolute value of results depends on 'sensitivity coefficients'. (authors) [French] Le spectrometre de masse a etincelles, de type MS7, est destine a l'analyse chimique de traces dans les solides, sans echantillons etalons. L'emploi de catalogues de 12 000 raies, elabores au laboratoire, permet un depouillement rapide des spectres, malgre leur complexite due aux ionisations multiples et aux associations d'atomes. Le niveau d'apparition d'une impurete donne une estimation de sa teneur, mais la valeur du renseignement depend de la preparation des electrodes et de la connaissance plus ou moins approfondie des processus d'ionisation dans l'etincelle et de noircissement des emulsions photographiques. Les mesures photometriques augmentent la precision des resultats, si l'on determine systematiquement la courbe de noircissement de chaque plaque. De meme la reproductibilite est amelioree si l'on tient compte des fluctuations statistiques du noircissement de l'emulsion par les ions de la matrice. Actuellement, les concentrations mesurees dans le domaine de 0,01 a 1000 ppm atomiques sont reproductibles a 20 pour cent pres, mais leur valeur absolue n'est assuree qu'a un coefficient 3 pres. Des etudes sont en cours pour calibrer l'appareil en valeur absolue, par une determination des coefficients de sensibilite a partir d'echantillons etalons. (auteurs)

  13. Standard methods for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    All methods described for subsampling and analysis of UF 6 are in routine use at United States Atomic Energy Commission installations. A gravimetric method is included for U and titrimetric methods, for Cl 2 and U. Mass spectrometric methods are given for both double and single standard procedures for U-isotopic content and for semiquantitative determination of hydrocarbons, chlorocarbons, and partially substituted halohydrocarbons. Spectroscopic methods are described for 232 U, fission products, Pu, and Np. In some instances an ion exchange- or extraction-separation is specified prior to the spectroscopic determination. Mass spectroscopic procedures for 31 trace elements are included, as are spectrophotometric methods for Br 2 , Si, P, Ti, V, W, Th, and Mo. Following a preliminary separation for some elements, emission spectroscopic procedures are described for B, Si, Ru, Hf, Mo, Nb, Ta, Ti, W, Zr, V, Th, rare earths, and other elements. Procedures for the determination of Sb, Ru, Al, Cd, Co, Ca, Cr, Fe, Pb, Mg, Mn, Ni, K, Na, and Zn by atomic absorption methods are included. The preparation of high-purity U 3 O 8 by the hydrolysis of UF 6 to UO 2 F 2 which upon drying and pyrohydrolysis yields U 3 O 8 is described

  14. The potential of organic (electrospray- and atmospheric pressure chemical ionisation) mass spectrometric techniques coupled to liquid-phase separation for speciation analysis.

    Science.gov (United States)

    Rosenberg, Erwin

    2003-06-06

    The use of mass spectrometry based on atmospheric pressure ionisation techniques (atmospheric pressure chemical ionisation, APCI, and electrospray ionisation, ESI) for speciation analysis is reviewed with emphasis on the literature published in and after 1999. This report accounts for the increasing interest that atmospheric pressure ionisation techniques, and in particular ESI, have found in the past years for qualitative and quantitative speciation analysis. In contrast to element-selective detectors, organic mass spectrometric techniques provide information on the intact metal species which can be used for the identification of unknown species (particularly with MS-MS detection) or the confirmation of the actual presence of species in a given sample. Due to the complexity of real samples, it is inevitable in all but the simplest cases to couple atmospheric pressure MS detection to a separation technique. Separation in the liquid phase (capillary electrophoresis or liquid chromatography in reversed phase, ion chromatographic or size-exclusion mode) is particularly suitable since the available techniques cover a very wide range of analyte polarities and molecular mass. Moreover, derivatisation can normally be avoided in liquid-phase separation. Particularly in complex environmental or biological samples, separation in one dimension is not sufficient for obtaining adequate resolution for all relevant species. In this case, multi-dimensional separation, based on orthogonal separation techniques, has proven successful. ESI-MS is also often used in parallel with inductively coupled plasma MS detection. This review is structured in two parts. In the first, the fundamentals of atmospheric pressure ionisation techniques are briefly reviewed. The second part of the review discusses recent applications including redox species, use of ESI-MS for structural elucidation of metal complexes, characterisation and quantification of small organometallic species with relevance to

  15. Isotope dilution inductively coupled plasma quadrupole mass spectrometry in connection with a chromatographic separation for ultra trace determinations of platinum group elements (Pt, Pd, Ru, Ir) in environmental samples.

    Science.gov (United States)

    Müller, M; Heumann, K G

    2000-09-01

    An isotope dilution inductively coupled plasma quadrupole mass spectrometric (ID-ICP-QMS) method was developed for the simultaneous determination of the platinum group elements Pt, Pd, Ru, and Ir in environmental samples. Spike solutions, enriched with the isotopes 194Pt, 108Pd, 99Ru, and 191Ir, were used for the isotope dilution step. Interfering elements were eliminated by chromatographic separation using an anion-exchange resin. Samples were dissolved with aqua regia in a high pressure asher. Additional dissolution of possible silicate portions by hydrofluoric acid was usually not necessary. Detection limits of 0.15 ng x g(-1), 0.075 ng x g(-1), and 0.015 ng x g(-1) were achieved for Pt, Pd, Ru, and Ir, respectively, using sample weights of only 0.2 g. The reliability of the ID-ICP-QMS method was demonstrated by analyzing a Canadian geological reference material and by participating in an interlaboratory study for the determination of platinum and palladium in a homogenized road dust sample. Surface soil, sampled at different distances from a highway, showed concentrations in the range of 0.1-87 ng x g(-1). An exponential decrease of the platinum and palladium concentration with increasing distance and a small anthropogenic contribution to the natural background concentration of ruthenium and iridium was found in these samples.

  16. Standard test methods for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade plutonium nitrate solutions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 These test methods cover procedures for the chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade plutonium nitrate solutions to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Plutonium by Controlled-Potential Coulometry Plutonium by Amperometric Titration with Iron(II) Plutonium by Diode Array Spectrophotometry Free Acid by Titration in an Oxalate Solution 8 to 15 Free Acid by Iodate Precipitation-Potentiometric Titration Test Method 16 to 22 Uranium by Arsenazo I Spectrophotometric Test Method 23 to 33 Thorium by Thorin Spectrophotometric Test Method 34 to 42 Iron by 1,10-Phenanthroline Spectrophotometric Test Method 43 to 50 Impurities by ICP-AES Chloride by Thiocyanate Spectrophotometric Test Method 51 to 58 Fluoride by Distillation-Spectrophotometric Test Method 59 to 66 Sulfate by Barium Sulfate Turbidimetric Test Method 67 to 74 Isotopic Composition by Mass Spectrom...

  17. Identification and quantification of flavonoids in human urine samples by column switching liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, S. E.; Freese, R.; Cornett, Claus

    2000-01-01

    A rapid and sensitive high-performance liquid chromatographic mass spectrometric (HPLC-MS) method is described for the determination and quantification of 12 dietary flavonoid glycosides and aglycons in human urine samples. Chromatographic separation of the analytes of interest was achieved...... by column-switching, using the first column (a Zorbax 300SB C-3 column) for sample cleanup and eluting the heart-cut flavonoid fraction onto the second column (a Zorbax SE C-18 column) for separation and detection by ultraviolet and atmospheric pressure chemical ionization MS using single ion monitoring...... of variation for the analysis of the 12 different flavonoids in quality control urine samples were 12.3% on average (range 11.0-13.7%, n = 24, reproducibility) and the repeatability of the assay were 5.0% (mean, range 0.1-14.8%, it = 12). A subset of 10 urine samples from a human dietary intervention study...

  18. Development and validation of a highly sensitive gas chromatographic-mass spectrometric screening method for the simultaneous determination of nanogram levels of fentanyl, sufentanil and alfentanil in air and surface contamination wipes.

    Science.gov (United States)

    Van Nimmen, Nadine F J; Veulemans, Hendrik A F

    2004-05-07

    A highly sensitive gas chromatographic-mass spectrometric (GC-MS) analytical method for the determination of the opioid narcotics fentanyl, alfentanil, and sufentanil in industrial hygiene personal air samples and surface contamination wipes was developed and comprehensively validated. Sample preparation involved a single step extraction of the samples with methanol, fortified with a fixed amount of the penta-deuterated analogues of the opioid narcotics as internal standard. The GC-MS analytical procedure using selected ion monitoring (SIM) was shown to be highly selective. Linearity was shown for levels of extracted wipe and air samples corresponding to at least 0.1-2 times their surface contamination limit (SCL) and accordingly to 0.1-2 times their time weighted average occupational exposure limit (OEL-TWA) based on a full shift 9601 air sample. Extraction recoveries were determined for spiked air samples and surface wipes and were found to be quantitative for both sampling media in the entire range studied. The air sampling method's limit of detection (LOD) was determined to be 0.4 ng per sample for fentanyl and sufentanil and 1.6 ng per sample for alfentanil, corresponding to less than 1% of their individual OEL for a full shift air sample (9601). The limit of quantification (LOQ) was found to be 1.4, 1.2, and 5.0 ng per filter for fentanyl, sufentanil, and alfentanil, respectively. The wipe sampling method had LODs of 4 ng per wipe for fentanyl and sufentanil and 16 ng per wipe for alfentanil and LOQs of respectively, 14, 12, and 50 ng per wipe. The analytical intra-assay precision of the air sampling and wipe sampling method, defined as the coefficient of variation on the analytical result of six replicate spiked media was below 10 and 5%, respectively, for all opioids at all spike levels. Accuracy expressed as relative error was determined to be below 10%, except for alfentanil at the lowest spike level (-13.1%). The stability of the opioids during simulated

  19. Mass spectrometric detection of proteins in non-aqueous media : the case of prion proteins in biodiesel

    Energy Technology Data Exchange (ETDEWEB)

    Douma, M.D.; Kerr, G.M.; Brown, R.S.; Keller, B.O.; Oleschuk, R.D. [Queen' s Univ., Kingston, ON (Canada). Dept. of Chemistry

    2008-08-15

    This paper presented a filtration method for detecting protein traces in non-aqueous media. The extraction technique used a mixture of acetonitrile, non-ionic detergent and water along with filter disks with embedded C{sub 8}-modified silica particles to capture the proteins from non-aqueous samples. The extraction process was then followed by an elution of the protein from the filter disk and direct mass spectrometric detection and tryptic digestion with peptide mapping and MS/MS fragmentation of protein-specific peptides. The method was used to detect prion proteins in spiked biodiesel samples. A tryptic peptide with the sequence YGQGSPGGNR was used for unambiguous identification. Results of the study showed that the method is suitable for the large-scale testing of protein impurities in tallow-based biodiesel production processes. 33 refs., 6 figs.

  20. Nonane as a radiolytic product in irradiated bacon

    International Nuclear Information System (INIS)

    Singh, H.; Guerrero, A.; Kremers, W.

    1993-01-01

    Formation of nonane in irradiated bacon has been confirmed by gas chromatographic/mass spectrometric (GC/MS) analysis of irradiated nitrogen-flushed homogenized bacon in scaled glass vials. Unirradiated bacon did not show the presence of nonane under similar conditions

  1. Simultaneous analysis of plasma free fatty acids and their 3-hydroxy analogs in fatty acid beta-oxidation disorders

    NARCIS (Netherlands)

    Costa, C. G.; Dorland, L.; Holwerda, U.; de Almeida, I. T.; Poll-The, B. T.; Jakobs, C.; Duran, M.

    1998-01-01

    We present a new derivatization procedure for the simultaneous gas chromatographic-mass spectrometric analysis of free fatty acids and 3-hydroxyfatty acids in plasma. Derivatization of target compounds involved trifluoroacetylation of hydroxyl groups and tert-butyldimethylsilylation of the carboxyl

  2. Site-Specific Hydrogen Isotope Composition of Propane: Mass spectrometric methods, equilibrium temperature dependence, and kinetics of exchange

    Science.gov (United States)

    Xie, H.; Ponton, C.; Kitchen, N.; Lloyd, M. K.; Lawson, M.; Formolo, M. J.; Eiler, J. M.

    2016-12-01

    -specific thermometer; these experiments also provide a reference frame for reporting mass spectrometric data. Differential H-exchange rates of the two molecular sites in propane could be a new tool to constrain thermal history of sub-surface propane. Our experimental and mass spectrometric approaches should be generalizable to other hydrocarbon compounds.

  3. Full second order chromatographic/spectrometric data matrices for automated sample identification and component analysis by non-data-reducing image analysis

    DEFF Research Database (Denmark)

    Nielsen, Niles-Peter Vest; Smedsgaard, Jørn; Frisvad, Jens Christian

    1999-01-01

    A data analysis method is proposed for identification and for confirmation of classification schemes, based on single- or multiple-wavelength chromatographic profiles. The proposed method works directly on the chromatographic data without data reduction procedures such as peak area or retention...... classes from the reference chromatograms, This feature is a valuable aid in selecting components for further analysis, The identification method is demonstrated on two data sets: 212 isolates from 41 food-borne Penicillium species and 61 isolates from 6 soil-borne Penicillium species. Both data sets...

  4. A critical assessment of the performance criteria in confirmatory analysis for veterinary drug residue analysis using mass spectrometric detection in selected reaction monitoring mode

    NARCIS (Netherlands)

    Berendsen, Bjorn J.A.; Meijer, Thijs; Wegh, Robin; Mol, Hans G.J.; Smyth, Wesley G.; Armstrong Hewitt, S.; Ginkel, van Leen; Nielen, Michel W.F.

    2016-01-01

    Besides the identification point system to assure adequate set-up of instrumentation, European Commission Decision 2002/657/EC includes performance criteria regarding relative ion abundances in mass spectrometry and chromatographic retention time. In confirmatory analysis, the relative abundance

  5. Mass spectrometric analysis of electrophoretically separated allergens and proteases in grass pollen diffusates

    Directory of Open Access Journals (Sweden)

    Geczy Carolyn L

    2003-09-01

    Full Text Available Abstract Background Pollens are important triggers for allergic asthma and seasonal rhinitis, and proteases released by major allergenic pollens can injure airway epithelial cells in vitro. Disruption of mucosal epithelial integrity by proteases released by inhaled pollens could promote allergic sensitisation. Methods Pollen diffusates from Kentucky blue grass (Poa pratensis, rye grass (Lolium perenne and Bermuda grass (Cynodon dactylon were assessed for peptidase activity using a fluorogenic substrate, as well as by gelatin zymography. Following one- or two-dimensional gel electrophoresis, Coomassie-stained individual bands/spots were excised, subjected to tryptic digestion and analysed by mass spectrometry, either MALDI reflectron TOF or microcapillary liquid chromatography MS-MS. Database searches were used to identify allergens and other plant proteins in pollen diffusates. Results All pollen diffusates tested exhibited peptidase activity. Gelatin zymography revealed high Mr proteolytic activity at ~ 95,000 in all diffusates and additional proteolytic bands in rye and Bermuda grass diffusates, which appeared to be serine proteases on the basis of inhibition studies. A proteolytic band at Mr ~ 35,000 in Bermuda grass diffusate, which corresponded to an intense band detected by Western blotting using a monoclonal antibody to the timothy grass (Phleum pratense group 1 allergen Phl p 1, was identified by mass spectrometric analysis as the group 1 allergen Cyn d 1. Two-dimensional analysis similarly demonstrated proteolytic activity corresponding to protein spots identified as Cyn d 1. Conclusion One- and two-dimensional electrophoretic separation, combined with analysis by mass spectrometry, is useful for rapid determination of the identities of pollen proteins. A component of the proteolytic activity in Bermuda grass diffusate is likely to be related to the allergen Cyn d 1.

  6. On the ability of the Viking gas chromatograph-mass spectrometer to detect organic matter.

    Science.gov (United States)

    Biemann, Klaus

    2007-06-19

    A recent paper by Navarro-Gonzalez et al. [Navarro-Gonzalez R, Navarro KF, de la Rosa J, Iniguez E, Molina P, Miranda LD, Morales P, Cienfuegos E, Coll P, Raulin F, et al. (2006) Proc Natl Acad Sci USA 103:16089-16094] claims to show that the Viking GCMS (gas chromatograph-mass spectrometer) experiment, which carried out a search for organic matter at the surface of Mars in 1976, "may have been blind to low levels of organics." To rebut this assertion, the Viking experiment, test data, and results on Mars are reviewed, and the fallacies in the design, execution, and interpretation of the new experiments presented by Navarro-Gonzalez et al. are critically examined.

  7. Multi-element determination in environmental samples by mass spectrometric isotope dilution analysis using thermal ionization. Pt. 2

    International Nuclear Information System (INIS)

    Hilpert, K.; Waidmann, E.

    1988-01-01

    An analytical procedure for the multi-element analysis of the elements Fe, Ni, Cu, Zn, Ga, Rb, Sr, Cd, Ba, Tl, and Pb in pine needles by mass spectrometric isotope dilution analysis using thermal ionization has been reported in Part I of this paper. This procedure is now transferred to the non-vegetable material 'Oyster Tissue' (Standard Reference Material 1566, National Bureau of Standards, USA). By a modification of the analytical procedure, it was possible to determine Cr in this material in addition to the aforementioned elements. No concentrations are certified for the elements Ga, Ba and Tl analyzed in this work. The concentrations of the remaining elements obtained by the multi-element analysis agree well with those certified. (orig.)

  8. Vaporization study on vanadium-oxygen solid solution by mass spectrometric method

    International Nuclear Information System (INIS)

    Banchorndhevakul, W.; Matsui, Tsuneo; Naito, Keiji

    1986-01-01

    The vapor pressures over vanadium-oxygen solid solution (0.001 ≤ O/V ≤ 0.145) were measured by mass-spectrometric method in the temperature range of 1,855 ∼ 2,117 K. The main vapor species were observed to be V(g) and VO(g). The vapor pressure of V(g) is higher than that of VO(g) over the solid solutions with all O/V ratios except for O/V = 0.145. The vapor pressure of V(g) is nearly independent of O/V ratio. The vapor pressure of VO(g) decreases with decreasing O/V ratio. The oxygen partial pressure was calculated as a function of temperature and O/V ratio from the vapor pressures of V(g) and VO(g), from which the partial molar enthalpy and entropy of oxygen in the solid solution were determined. The partial molar enthalpy of oxygen was observed to be independent of composition, suggesting the presence of very weak interaction between interstitial oxygens. The compositional dependence of the partial molar entropy of oxygen can be explained by assuming the occupation of the octahedral site in bcc vanadium lattice by the interstitial oxygens. The excess partial molar entropy of oxygen was compared with the value derived from the sum of the contributions from the volume expansion, electronic heat capacity and vibrational terms. (author)

  9. Determination of rare earth elements by liquid chromatographic separation using inductively coupled plasma mass spectrometric detection

    International Nuclear Information System (INIS)

    Braverman, D.S.

    1992-01-01

    High-performance liquid chromatography (HPLC) is used to separate the rare earth elements (REEs) prior to detection by inductively coupled plasma mass spectrometry (ICP-MS). The use of HPLC-ICP-MS in series combines the separation power and speed of HPLC with the sensitivity, isotopic selectivity and speed of ICP-MS. The detection limits for the REEs are in the sub-ng ml -1 range and the response is linear over four orders of magnitude. A preliminary comparison of isotope dilution and external standard results for the determination of REEs in National Institute of Standards and Technology (NIST) Standard Reference Material (SRM 1633a) Fly Ash is presented. (author)

  10. A Sensitive and Robust Ultra HPLC Assay with Tandem Mass Spectrometric Detection for the Quantitation of the PARP Inhibitor Olaparib (AZD2281 in Human Plasma for Pharmacokinetic Application

    Directory of Open Access Journals (Sweden)

    Jeffrey Roth

    2014-06-01

    Full Text Available Olaparib (AZD2281 is an orally active PARP-1 inhibitor, primarily effective against cancers with BRCA1/2 mutations. It is currently in Phase III development and has previously been investigated in numerous clinical trials, both as a single agent and in combination with chemotherapy. Despite this widespread testing, there is only one published method that provides assay details and stability studies for olaparib alone. A more sensitive uHPLC-MS/MS method for the quantification of olaparib in human plasma was developed, increasing the range of quantification at both ends (0.5–50,000 ng/mL compared to previously published methods (10–5,000 ng/mL. The wider range encompasses CMAX levels produced by typical olaparib doses and permits better pharmacokinetic modeling of olaparib elimination. This assay also utilizes a shorter analytical runtime, allowing for more rapid quantification and reduced use of reagents. A liquid-liquid extraction was followed by chromatographic separation on a Waters UPLC® BEH C18 column (2.1 × 50 mm, 1.7 µm and mass spectrometric detection. The mass transitions m/z 435.4→281.1 and m/z 443.2→281.1 were used for olaparib and the internal standard [2H8]-olaparib, respectively. The assay proved to be accurate (<9% deviation and precise (CV < 11%. Stability studies showed that olaparib is stable at room temperature for 24 h. in whole blood, at 4 °C for 24 h post-extraction, at −80 °C in plasma for at least 19 months, and through three freeze-thaw cycles. This method proved to be robust for measuring olaparib levels in clinical samples from a Phase I trial.

  11. Mass spectrometric analysis of small negative ions (e/m < 100) produced by Trichel pulse negative corona discharge fed by ozonised air

    OpenAIRE

    Skalny, J.D.; Horvath, G.; Mason, N.

    2007-01-01

    Mass spectrometric analysis of small negative ions (e/m < 100) produced by DC negative corona discharge in ozonised wet air both in flow and flow-stopped regimes was conducted at pressure of 30 kPa. The point-to-plain electrode system has been used. The yield of individual ions is strongly affected by trace concentrations of ozone in both regimes. Ozone concentration greater than 25 ppm is sufficient to completely suppress the appearance of O2- and a NO2- ion as well as theirs clusters in the...

  12. Mild performic acid oxidation enhances chromatographic and top down mass spectrometric analyses of histones.

    Science.gov (United States)

    Pesavento, James J; Garcia, Benjamin A; Streeky, James A; Kelleher, Neil L; Mizzen, Craig A

    2007-09-01

    Recent developments in top down mass spectrometry have enabled closely related histone variants and their modified forms to be identified and quantitated with unprecedented precision, facilitating efforts to better understand how histones contribute to the epigenetic regulation of gene transcription and other nuclear processes. It is therefore crucial that intact MS profiles accurately reflect the levels of variants and modified forms present in a given cell type or cell state for the full benefit of such efforts to be realized. Here we show that partial oxidation of Met and Cys residues in histone samples prepared by conventional methods, together with oxidation that can accrue during storage or during chip-based automated nanoflow electrospray ionization, confounds MS analysis by altering the intact MS profile as well as hindering posttranslational modification localization after MS/MS. We also describe an optimized performic acid oxidation procedure that circumvents these problems without catalyzing additional oxidations or altering the levels of posttranslational modifications common in histones. MS and MS/MS of HeLa cell core histones confirmed that Met and Cys were the only residues oxidized and that complete oxidation restored true intact abundance ratios and significantly enhanced MS/MS data quality. This allowed for the unequivocal detection, at the intact molecule level, of novel combinatorially modified forms of H4 that would have been missed otherwise. Oxidation also enhanced the separation of human core histones by reverse phase chromatography and decreased the levels of salt-adducted forms observed in ESI-FTMS. This method represents a simple and easily automated means for enhancing the accuracy and sensitivity of top down analyses of combinatorially modified forms of histones that may also be of benefit for top down or bottom up analyses of other proteins.

  13. Rapid Quantification of 25-Hydroxyvitamin D3 in Human Serum by Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry

    Science.gov (United States)

    Qi, Yulin; Müller, Miriam; Stokes, Caroline S.; Volmer, Dietrich A.

    2018-04-01

    LC-MS/MS is widely utilized today for quantification of vitamin D in biological fluids. Mass spectrometric assays for vitamin D require very careful method optimization for precise and interference-free, accurate analyses however. Here, we explore chemical derivatization and matrix-assisted laser desorption/ionization (MALDI) as a rapid alternative for quantitative measurement of 25-hydroxyvitamin D3 in human serum, and compare it to results from LC-MS/MS. The method implemented an automated imaging step of each MALDI spot, to locate areas of high intensity, avoid sweet spot phenomena, and thus improve precision. There was no statistically significant difference in vitamin D quantification between the MALDI-MS/MS and LC-MS/MS: mean ± standard deviation for MALDI-MS—29.4 ± 10.3 ng/mL—versus LC-MS/MS—30.3 ± 11.2 ng/mL (P = 0.128)—for the sum of the 25-hydroxyvitamin D epimers. The MALDI-based assay avoided time-consuming chromatographic separation steps and was thus much faster than the LC-MS/MS assay. It also consumed less sample, required no organic solvents, and was readily automated. In this proof-of-concept study, MALDI-MS readily demonstrated its potential for mass spectrometric quantification of vitamin D compounds in biological fluids.

  14. A novel mass spectrometric strategy "BEMAP" reveals Extensive O-linked protein glycosylation in Enterotoxigenic Escherichia coli

    DEFF Research Database (Denmark)

    Boysen, Anders; Palmisano, Giuseppe; Krogh, Thøger Jensen

    2016-01-01

    The attachment of sugars to proteins via side-chain oxygen atoms (O-linked glycosylation) is seen in all three domains of life. However, a lack of widely-applicable analytical tools has restricted the study of this process, particularly in bacteria. In E. coli, only four O-linked glycoproteins have...... previously been characterized. Here we present a glycoproteomics technique, termed BEMAP, which is based on the beta-elimination of O-linked glycans followed by Michael-addition of a phosphonic acid derivative, and subsequent titanium dioxide enrichment. This strategy allows site-specific mass......-spectrometric identification of proteins with O-linked glycan modifications in a complex biological sample. Using BEMAP we identified cell surface-associated and membrane vesicle glycoproteins from Enterotoxigenic E. coli (ETEC) and non-pathogenic E. coli K-12. We identified 618 glycosylated Serine and Threonine residues...

  15. Label-assisted mass spectrometry for the acceleration of reaction discovery and optimization

    Science.gov (United States)

    Cabrera-Pardo, Jaime R.; Chai, David I.; Liu, Song; Mrksich, Milan; Kozmin, Sergey A.

    2013-05-01

    The identification of new reactions expands our knowledge of chemical reactivity and enables new synthetic applications. Accelerating the pace of this discovery process remains challenging. We describe a highly effective and simple platform for screening a large number of potential chemical reactions in order to discover and optimize previously unknown catalytic transformations, thereby revealing new chemical reactivity. Our strategy is based on labelling one of the reactants with a polyaromatic chemical tag, which selectively undergoes a photoionization/desorption process upon laser irradiation, without the assistance of an external matrix, and enables rapid mass spectrometric detection of any products originating from such labelled reactants in complex reaction mixtures without any chromatographic separation. This method was successfully used for high-throughput discovery and subsequent optimization of two previously unknown benzannulation reactions.

  16. Quantum dots assisted laser desorption/ionization mass spectrometric detection of carbohydrates: qualitative and quantitative analysis.

    Science.gov (United States)

    Bibi, Aisha; Ju, Huangxian

    2016-04-01

    A quantum dots (QDs) assisted laser desorption/ionization mass spectrometric (QDA-LDI-MS) strategy was proposed for qualitative and quantitative analysis of a series of carbohydrates. The adsorption of carbohydrates on the modified surface of different QDs as the matrices depended mainly on the formation of hydrogen bonding, which led to higher MS intensity than those with conventional organic matrix. The effects of QDs concentration and sample preparation method were explored for improving the selective ionization process and the detection sensitivity. The proposed approach offered a new dimension to the application of QDs as matrices for MALDI-MS research of carbohydrates. It could be used for quantitative measurement of glucose concentration in human serum with good performance. The QDs served as a matrix showed the advantages of low background, higher sensitivity, convenient sample preparation and excellent stability under vacuum. The QDs assisted LDI-MS approach has promising application to the analysis of carbohydrates in complex biological samples. Copyright © 2016 John Wiley & Sons, Ltd.

  17. Mass spectrometric 230Th-234U-238U dating of the Devils Hole calcite vein

    International Nuclear Information System (INIS)

    Ludwig, K.R.; Simmons, K.R.; Szabo, B.J.; Riggs, A.C.; Winograd, I.J.; Landwehr, J.M.; Hoffman, R.J.

    1992-01-01

    The Devils Hole calcite vein contains a long-term climatic record, but requires accurate chronologic control for its interpretation. Mass-spectrometric U-series ages for samples from core DH-11 yielding 230 Th ages with precisions ranging from less than 1,000 years (2σ) for samples younger than ∼140 ka (thousands of years ago) to less than 50,000 years for the oldest samples (∼566 ka). The 234 U/ 238 U ages could be determined to a precision of ∼20,000 years for all ages. Calcite accumulated continuously from 566 ka until ∼60 ka at an average rate of 0.7 millimeter per 10 3 years. The precise agreement between replicate analyses and the concordance of the 230 Th/ 238 U and 234 U/ 238 U ages for the oldest samples indicate that the DH-11 samples were closed systems and validate the dating technique in general

  18. Characterization of coal-derived liquids and other fossil-fuel-related materials employing mass spectrometry. Final report, September 30, 1976-September 29, 1980

    Energy Technology Data Exchange (ETDEWEB)

    Scheppele, S E

    1982-05-01

    A document was prepared which assessed the state-of-the art in the mass spectrometric characterization of fossil fuel materials and the relevance of these data to the fossil fuel industry. A Kratos DS50 SM data system was successfully interfaced to a CEC 21-110B mass spectrometer. Communications between the NOVA 3/12 computer in the data system and the OSU central computer were established. A Grant Comparator/Microdensitometer was acquired and made operational. Plans were developed and hardware acquired for interfacing the densitometer to the NOVA 3/12 computer. A quartz direct introduction probe was acquired for the CEC 21-110B. A temperature controller for the probe was acquired and interfaced to the slow speed ADC on the auxillary board in the data system/mass spectrometer interface. The combined FI/EI source was modified to operate in the FD mode and an apparatus was fabricated for conditioning FD emitters. A CSI supergrater 3 was interfaced to the PE 3920 gas chromatograph. The upgraded facility was used to develop mass spectrometric methods for the characterization of fossil fuel materials and to apply methods to the characterization of these materials. Activities included: (1) initial development of field-ionization mass spectrometry for the characterization of saturated hydrocarbons, (2) computerization of the technique of probe microdistillation/mass spectrometry, (3) initation of the development of a new method for the computer assisted assignment of formulas to ion masses, (4) characterization of neutral fractions from a hydrotreated tar-sands oil, and (5) characterization of coal-derived oils and asphaltenes.

  19. Spectrometric techniques 3

    CERN Document Server

    Vanasse, George A

    2013-01-01

    Spectrometric Techniques, Volume III presents the applications of spectrometric techniques to atmospheric and space studies. This book reviews the spectral data processing and analysis techniques that are of broad applicability.Organized into five chapters, this volume begins with an overview of the instrumentation used for obtaining field data. This text then reviews the contribution that space-borne spectroscopy in the thermal IR has made to the understanding of the planets. Other chapters consider the instruments that have recorded the planetary emission spectra. This book discusses as well

  20. Bio-analytical method development and validation of Rasagiline by high performance liquid chromatography tandem mass spectrometry detection and its application to pharmacokinetic study

    Directory of Open Access Journals (Sweden)

    Ravi Kumar Konda

    2012-10-01

    Full Text Available The most suitable bio-analytical method based on liquid–liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm×50 mm, 3.5 μm column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The total run time was 3.0 min. The proposed method has been validated with the linear range of 5–12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3%–2.9% and 1.6%–2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition. Keywords: High performance liquid chromatography, Mass spectrometry, Rasagiline, Liquid–liquid extraction

  1. Electron multiplier for the measurement of an ion current on a mass spectrometer; Multiplicateur d'electrons pour la mesure de courant d'ions sur un spectrometre de masse

    Energy Technology Data Exchange (ETDEWEB)

    Lohez, P; Nief, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    The apparatus described is designed to measure weak ion currents received at the collector of a mass spectrometer. The report describes successively the study of electron paths in the multiplier by the method of analogy, using rubber membranes, and the practical details of construction of the apparatus. The variation with surface treatment of the secondary emission coefficient of the alloy CuBe containing 2 per cent Be, which makes up the dynodes, and the influence of the voltage on the gain per stage, are discussed. Results of tests regarding: the influence of the ion mass on the gain, the background of the instrument and the energy distribution of the impulses coming out on a high gain multiplier (q.q. 10{sup 7}) are given. Finally the performances of the multiplier are reported. 1- For a low gain (10{sup 4}), precision and reproducibility comparable to the electrometer valve, sensitivity 100 times greater, currents capable of detection 10{sup -17} Ampere. 2- For a high gain (10{sup 7}) and measurement by impulse counting, currents capable of detection 10{sup -19} Ampere. Mounting difficult to use on a mass spectrometer. (author) [French] L'appareil decrit est destine a la mesure des faibles courants d'ions re s au collecteur d'un spectrometre de masse. Le rapport decrit successivement l'etude des trajectoires des electrons dans le multiplicateur, par la methode analogique de la menbrane en caoutchouc, et la realisation pratique de l'appareil. La variation du coefficient d'emission secondaire de l'alliage CuBe a 2 pour cent de Be, constituant les dynodes suivant le traitement des surfaces, et l'influence de la tension sur le gain par etage sont discutees. Des resultats d'essais concernant: l'influence de la masse des ions sur le gain, le bruit de fond de l'appareil et la repartition en energie des impulsions de sortie sur un multiplicateur a gain eleve (q.q. 10{sup 7}) sont donnes. Enfin, sont rapportees les performances du multiplicateur. 1- pour un gain faible

  2. Inductively coupled plasma emission spectrometric detection of simulated high performance liquid chromatographic peaks

    International Nuclear Information System (INIS)

    Fraley, D.M.; Yates, D.; Manahan, S.E.

    1979-01-01

    Because of its multielement capability, element-specificity, and low detection limits, inductively coupled plasma optical emission spectrometry (ICP) is a very promising technique for the detection of specific elemental species separated by high performance liquid chromatography (HPLC). This paper evaluated ICP as a detector for HPLC peaks containing specific elements. Detection limits for a number of elements have been evaluated in terms of the minimum detectable concentration of the element at the chromatographic peak maximum. The elements studies were Al, As, B, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Na, Ni, P, Pb, Sb, Se, Sr, Ti, V, and Zn. In addition, ICP was compared with atomic absorption spectrometry for the detection of HPLC peaks composed of EDTA and NTA chelates of copper. Furthermore, ICP was compared to uv solution absorption for the detection of copper chelates. 6 figures, 4 tables

  3. Uncertainty assessment in gamma spectrometric measurements of plutonium isotope ratios and age

    Energy Technology Data Exchange (ETDEWEB)

    Ramebaeck, H., E-mail: henrik.ramebeck@foi.se [Swedish Defence Research Agency, FOI, Division of CBRN Defence and Security, SE-901 82 Umea (Sweden); Chalmers University of Technology, Department of Chemical and Biological Engineering, Nuclear Chemistry, SE-412 96 Goeteborg (Sweden); Nygren, U.; Tovedal, A. [Swedish Defence Research Agency, FOI, Division of CBRN Defence and Security, SE-901 82 Umea (Sweden); Ekberg, C.; Skarnemark, G. [Chalmers University of Technology, Department of Chemical and Biological Engineering, Nuclear Chemistry, SE-412 96 Goeteborg (Sweden)

    2012-09-15

    A method for the assessment of the combined uncertainty in gamma spectrometric measurements of plutonium composition and age was evaluated. Two materials were measured. Isotope dilution inductively coupled plasma sector field mass spectrometry (ID-ICP-SFMS) was used as a reference method for comparing the results obtained with the gamma spectrometric method for one of the materials. For this material (weapons grade plutonium) the measurement results were in agreement between the two methods for all measurands. Moreover, the combined uncertainty in all isotope ratios considered in this material (R{sub Pu238/Pu239}, R{sub Pu240/Pu239}, R{sub Pu241/Pu239}, and R{sub Am241/Pu241} for age determination) were limited by counting statistics. However, the combined uncertainty for the other material (fuel grade plutonium) were limited by the response fit, which shows that the uncertainty in the response function is important to include in the combined measurement uncertainty of gamma spectrometric measurements of plutonium.

  4. Determination of low-level acrylamide in drinking water by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Lucentini, Luca; Ferretti, Emanuele; Veschetti, Enrico; Achene, Laura; Turrio-Baldassarri, Luigi; Ottaviani, Massimo; Bogialli, Sara

    2009-01-01

    A simple and sensitive liquid chromatographic-tandem mass spectrometric (LC/MS/MS) method has been developed and validated to confirm and quantify acrylamide monomer (AA) in drinking water using [13C3] acrylamide as internal standard (IS). After a preconcentration by solid-phase extraction with spherical activated carbon, analytes were chromatographed on IonPac ICE-AS1 column (9 x 250 mm) under isocratic conditions using acetonitrile-water-0.1 M formic acid (43 + 52 + 5, v/v/v) as the mobile phase. Analysis was achieved using a triple-quadrupole mass analyzer equipped with a turbo ion spray interface. For confirmation and quantification of the analytes, MS data acquisition was performed in the multireaction monitoring mode, selecting 2 precursor ion to product ion transitions for both AA and IS. The method was validated for linearity, sensitivity, accuracy, precision, extraction efficiency, and matrix effect. Linearity in tap water was observed over the concentration range 0.1-2.0 microg/L. Limits of detection and quantification were 0.02 and 0.1 microg/L, respectively. Interday and intraday assays were performed across 3 validation levels (0.1, 0.5, and 1.5 microg/L). Accuracy (as mean recovery) ranged from 89.3 to 96.2% with relative standard deviation water in compliance with European Union and U.S. Environmental Protection Agency standards.

  5. Two-step ion-exchange chromatographic purification combined with reversed-phase chromatography to isolate C-peptide for mass spectrometric analysis.

    Science.gov (United States)

    Kabytaev, Kuanysh; Durairaj, Anita; Shin, Dmitriy; Rohlfing, Curt L; Connolly, Shawn; Little, Randie R; Stoyanov, Alexander V

    2016-02-01

    A liquid chromatography with mass spectrometry on-line platform that includes the orthogonal techniques of ion exchange and reversed phase chromatography is applied for C-peptide analysis. Additional improvement is achieved by the subsequent application of cation- and anion-exchange purification steps that allow for isolating components that have their isoelectric points in a narrow pH range before final reversed-phase mass spectrometry analysis. The utility of this approach for isolating fractions in the desired "pI window" for profiling complex mixtures is discussed. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Solid-phase microextraction for gas chromatographic/mass spectrometric analysis of dimethoate in human biological samples.

    Science.gov (United States)

    Gallardo, E; Barroso, M; Margalho, C; Cruz, A; Vieira, D N; López-Rivadulla, M

    2006-01-01

    A new, simple and rapid procedure for the determination of dimethoate in urine and blood samples was developed using direct immersion solid-phase microextraction and gas chromatography/mass spectrometry. This technique required only 0.1 mL of sample, and ethion was used as internal standard. Two types of coated fibre were compared (100 microm polydimethylsiloxane, and 65 microm Carbowax/divinylbenzene). Other parameters, such as extraction temperature, adsorption and desorption time, salt addition, agitation and pH, were optimized to enhance the sensitivity of the method. Limits of detection (LODs) and quantitation (LOQs) were 50 and 100 ng/mL for urine and 200 and 500 ng/mL for blood, respectively. The method was found to be linear between the LOQ and 40 microg/mL for urine, and between the LOQ and 50 microg/mL for blood, with correlation coefficients ranging from 0.9923-0.9996. Precision (intra- and interday) and accuracy were in conformity with the criteria normally accepted in bioanalytical method validation. The mean absolute recoveries of dimethoate were 1.24 and 0.50% for urine and blood, respectively. Because of its simplicity and the fact that small volumes of sample are used, the described method can be successfully used in the diagnosis of poisoning by this pesticide, namely in those situations where the sample volume is limited, as frequently occurs in forensic toxicology. Copyright 2006 John Wiley & Sons, Ltd.

  7. A new, simple assay for long-chain acyl-CoA dehydrogenase in cultured skin fibroblasts using stable isotopes and GC-MS

    NARCIS (Netherlands)

    Niezen-Koning, K. E.; Wanders, R. J.; Nagel, G. T.; IJlst, L.; Heymans, H. S.

    1992-01-01

    In this paper, we present a new method for measurement of long-chain acyl-CoA dehydrogenase (LCAD) activities in cultured skin fibroblasts. The method is based upon gas chromatographic/mass spectrometric determination of 3-OH-hexadecanoic acid formed during incubation of fibroblasts in a medium

  8. Sequence-specific capture of protein-DNA complexes for mass spectrometric protein identification.

    Directory of Open Access Journals (Sweden)

    Cheng-Hsien Wu

    Full Text Available The regulation of gene transcription is fundamental to the existence of complex multicellular organisms such as humans. Although it is widely recognized that much of gene regulation is controlled by gene-specific protein-DNA interactions, there presently exists little in the way of tools to identify proteins that interact with the genome at locations of interest. We have developed a novel strategy to address this problem, which we refer to as GENECAPP, for Global ExoNuclease-based Enrichment of Chromatin-Associated Proteins for Proteomics. In this approach, formaldehyde cross-linking is employed to covalently link DNA to its associated proteins; subsequent fragmentation of the DNA, followed by exonuclease digestion, produces a single-stranded region of the DNA that enables sequence-specific hybridization capture of the protein-DNA complex on a solid support. Mass spectrometric (MS analysis of the captured proteins is then used for their identification and/or quantification. We show here the development and optimization of GENECAPP for an in vitro model system, comprised of the murine insulin-like growth factor-binding protein 1 (IGFBP1 promoter region and FoxO1, a member of the forkhead rhabdomyosarcoma (FoxO subfamily of transcription factors, which binds specifically to the IGFBP1 promoter. This novel strategy provides a powerful tool for studies of protein-DNA and protein-protein interactions.

  9. Single-laboratory validation of a high-performance liquid chromatographic-diode array detector-fluorescence detector/mass spectrometric method for simultaneous determination of water-soluble vitamins in multivitamin dietary tablets.

    Science.gov (United States)

    Chen, Pei; Atkinson, Renata; Wolf, Wayne R

    2009-01-01

    The purpose of this study was to develop a single-laboratory validated (SLV) method using high-performance liquid chromatography with different detectors [diode array detector (DAD); fluorescence detector (FLD); and mass spectrometry (MS)] for determination of 7 B-complex vitamins (B1-thiamin, B2-riboflavin, B3-nicotinamide, B6-pyridoxine, B9-folic acid, pantothenic acid, and biotin) and vitamin C in multivitamin/multimineral dietary supplements. The method involves the use of a reversed-phase octadecylsilyl column (4 microm, 250 x 2.0 mm id) and a gradient mobile phase profile. Gradient elution was performed at a flow rate of 0.25 mL/min. After a 5 min isocratic elution at 100% A (0.1% formic acid in water), a linear gradient to 50% A and 50% B (0.1% formic acid in acetonitrile) at 15 min was employed. Detection was performed with a DAD as well as either an FLD or a triple-quadrupole MS detector in the multiple reaction monitoring mode. SLV was performed using Standard Reference Material (SRM) 3280 Multivitamin/Multimineral Tablets, being developed by the National Institute of Standards and Technology, with support by the Office of Dietary Supplements of the National Institutes of Health. Phosphate buffer (10 mM, pH 2.0) extracts of the NIST SRM 3280 were analyzed by the liquid chromatographic (LC)-DAD-FLDIMS method. Following extraction, the method does not require any sample cleanup/preconcentration steps except centrifugation and filtration.

  10. Chromatographic, Spectrometric and NMR Characterization of a New Set of Glucuronic Acid Esters Synthesized by Lipase

    Directory of Open Access Journals (Sweden)

    Michel Marlier

    2007-01-01

    Full Text Available An enzymatic synthesis was developed on a new set of D-glucuronic acid esters and particularly the tetradecyl-D-glucopyranosiduronate also named tetradecyl D-glucuronate. Chromatographic analyses revealed the presence of the ester as a mixture of anomeric forms for carbon chain lengths superior to 12. TOF/MS and MS/MS studies confirmed the synthesis of glucuronic acid ester. The NMR study also confirmed the structure of glucuronic acid esters and clearly revealed an anomeric (α/β ratio equivalent to 3/2

  11. A column exchange chromatographic procedure for the automated purification of analytical samples in nuclear spent fuel reprocessing and plutonium fuel fabrication

    International Nuclear Information System (INIS)

    Zahradnik, P.; Swietly, H.; Doubek, N.; Bagliano, G.

    1992-11-01

    A Column Exchange Chromatographic procedure using Tri-n-Octyl-Phosphine-Oxide (TOPO) as stationary phase, is in routine use at SAL since 1984 on nuclear spent fuel reprocessing and on Pu product samples, prior to alpha and mass spectrometric analysis. This standard procedure was further on modified in view of its automation in a glove box; the resulting new procedure is described in this paper. Laboratory Robot Compatible (LRC) disposable columns were selected because their dimensions are particularly favorable and reproducible. A less corrosive HNO 3 -HI mixture substituted the former HC1-HI plutonium eluant. The inorganic support of the stationary phase used to test the above mentioned changes was unexpectedly withdrawn from the market so that another support had to be selected and the procedure reoptimized accordingly. The resulting procedure was tested with the robot and validated against the manual procedure taken as reference: the comparison showed that the modified procedure meets the analytical requirements and has the same performance than the original procedure. (author). Refs, figs and tabs

  12. Surface ionization mass spectrometry of opiates

    International Nuclear Information System (INIS)

    Usmanov, D.T.

    2009-07-01

    Key words: surface ionization, adsorption, heterogeneous reactions, surface ionization mass spectrometry, thermodesorption surface ionization spectroscopy, thermoemitter, opiates, extracts of biosamples. Subjects of study. The mass - spectrometric study of thermal - ion emission: surface ionization of opiates by on the surface of oxidized refractory metals. Purpose of work is to establish the regularities of surface ionization (SI) of multi-atomic molecule opiates and their mixtures develop the scientific base of SI methods for high sensitive and selective detection and analysis of these substances in the different objects, including biosamples. Methods of study: surface ionization mass spectrometry, thermodesorption surface ionization spectroscopy. The results obtained and their novelty. For the first time, SI of molecule opiates on the oxidized tungsten surface has been studied and their SI mass-spectra and temperature dependences of ion currents have been obtained, the characteristic heterogeneous reactions of an adsorbed molecules and the channels of monomolecular decays vibrationally-excited ions on their way in mass-spectrometry have been revealed, sublimation energy has been defined, the activation energy of E act , of these decays has been estimated for given period of time. Additivity of the SI mass-spectra of opiate mixtures of has been established under conditions of joint opiate adsorption. High selectivity of SI allows the extracts of biosamples to be analyzed without their preliminary chromatographic separation. The opiates are ionized by SI with high efficiency (from 34 C/mol to 112 C/mol), which provides high sensitivity of opiate detection by SI/MS and APTDSIS methods from - 10 -11 g in the samples under analysis. Practical value. The results of these studies create the scientific base for novel SI methods of high sensitive detection and analysis of the trace amounts of opiates in complicated mixtures, including biosamples without their preliminary

  13. High-pressure liquid chromatographic assay of Bay n 7133 in human serum.

    OpenAIRE

    Fasching, C E; Hughes, C E; Hector, R F; Peterson, L R

    1984-01-01

    A high-pressure liquid chromatographic method that includes a Sep-Pak (Waters Associates, Inc., Milford , Mass.) preparation of human serum was employed for the quantitative assay of Bay n 7133. Drug levels of 0.1 to 20 micrograms/ml could be detected. No interference from amphotericin B was found in the chromatographic analysis of Bay n 7133.

  14. The interlaboratory experiment IDA-72 on mass spectrometric isotope dilution analysis. Vol. 1

    International Nuclear Information System (INIS)

    Beyrich, W.; Drosselmeyer, E.

    1975-07-01

    Within the framework of the Safeguards Project of the Federal Republic of Germany at the Nuclear Research Center Karlsruhe an analytical intercomparison program was carried out in cooperation with 22 laboratories of 13 countries or international organizations. The main objective was the acquisition of basic data on the errors involved in the mass spectrometric isotope dilution analysis if it is applied to the determination of uranium and plutonium in diluted active feed solutions of reprocessing plants in routine operation. The results were evaluated by statistical methods mainly in regard to the calculation of the estimates of the variances for the different error components contributing to the total error of this analytical technique. Furthermore, the performance of two new methods for sample conditioning suggested by the International Atomic Energy Agency, Vienna, and the European Institute for Transuranium Elements (EURATOM), Karlsruhe, was successfully tested. The results of some investigations on the stability of diluted high active feed solutions and on comparison analysis by X-ray fluorescence spectrometry are also included. Data on the analytical efforts (manhours) invested in this study are reported as well as general experiences made in the organization and performance of an experiment on such an extended international level. (orig.) [de

  15. Hydrophilic Interaction Liquid Chromatography-Tandem Mass Spectrometry Analysis of Fosetyl-Aluminum in Airborne Particulate Matter

    Directory of Open Access Journals (Sweden)

    Francesca Buiarelli

    2018-01-01

    Full Text Available Fosetyl-aluminum is a synthetic fungicide administered to plants especially to prevent diseases caused by the members of the Peronosporales and several Phytophthora species. Herein, we present a selective liquid chromatography-tandem mass spectrometry (LC-MS/MS method to analyze residues of fosetyl-A1 in air particulate matter. This study was performed in perspective of an exposure assessment of this substance of health concern in environments where high levels of fosetly-Al, relatively to airborne particulate matter, can be found after spraying it. The cleanup procedure of the analyte, from sampled filters of atmospheric particulate matter, was optimized using a Strata X solid-phase extraction cartridge, after accelerated extraction by using water. The chromatographic separation was achieved using a polymeric column based on hydrophilic interaction in step elution with water/acetonitrile, whereas the mass spectrometric detection was performed in negative electrospray ionization. The proposed method resulted to be a simple, fast, and suitable method for confirmation purposes.

  16. Mass spectrometric detection of 27-hydroxycholesterol in breast cancer exosomes.

    Science.gov (United States)

    Roberg-Larsen, Hanne; Lund, Kaja; Seterdal, Kristina Erikstad; Solheim, Stian; Vehus, Tore; Solberg, Nina; Krauss, Stefan; Lundanes, Elsa; Wilson, Steven Ray

    2017-05-01

    Exosomes from cancer cells are rich sources of biomarkers and may contain elevated levels of lipids of diagnostic value. 27-Hydroxycholesterol (27-OHC) is associated with proliferation and metastasis in estrogen receptor positive (ER+) breast cancer. In this study, we investigated the levels of 27-OHC, and other sidechain-hydroxylated oxysterols in exosomes. To study both cytoplasmic and exosomal oxysterol samples of limited size, we have developed a capillary liquid chromatography-mass spectrometry platform that outperforms our previously published systems regarding chromatographic resolution, analysis time and sensitivity. In the analyzed samples, the quantified level of cytoplasmic 27-OHC using this platform fitted with mRNA levels of 27-OHC's corresponding enzyme, CYP27A1. We find clearly increased levels of 27-OHC in exosomes (i.e., enrichment) from an ER+ breast cancer cell line (MCF-7) compared to exosomes derived from an estrogen receptor (ER-) breast cancer cell line (MDA-MB-231) and other control exosomes (non-cancerous cell line (HEK293) and human pooled serum). The exosomal oxysterol profile did not reflect cytoplasmic oxysterol profiles in the cells of origin; cytoplasmic 27-OHC was low in ER+ MCF-7 cells while high in MDA-MB-231 cells. Other control cancer cells showed varied cytoplasmic oxysterol levels. Hence, exosome profiling in cancer cells might provide complementary information with the possibility of diagnostic value. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Liquid chromatography/mass spectrometric determination of patulin in apple juice using atmospheric pressure photoionization.

    Science.gov (United States)

    Takino, Masahiko; Daishima, Shigeki; Nakahara, Taketoshi

    2003-01-01

    This paper describes a comparison between atmospheric pressure chemical ionization (APCI) and the recently introduced atmospheric pressure photoionization (APPI) technique for the liquid chromatography/mass spectrometric (LC/MS) determination of patulin in clear apple juice. A column switching technique for on-line extraction of clear apple juice was developed. The parameters investigated for the optimization of APPI were the ion source parameters fragmentor voltage, capillary voltage, and vaporizer temperature, and also mobile phase composition and flow rate. Furthermore, chemical noise and signal suppression of analyte signals due to sample matrix interference were investigated for both APCI and APPI. The results indicated that APPI provides lower chemical noise and signal suppression in comparison with APCI. The linear range for patulin in apple juice (correlation coefficient >0.999) was 0.2-100 ng mL(-1). Mean recoveries of patulin in three apple juices ranged from 94.5 to 103.2%, and the limit of detection (S/N = 3), repeatability and reproducibility were 1.03-1.50 ng mL(-1), 3.9-5.1% and 7.3-8.2%, respectively. The total analysis time was 10.0 min. Copyright 2003 John Wiley & Sons, Ltd.

  18. Standard test methods for chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade aluminum oxide and aluminum oxide-boron carbide composite pellets

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1994-01-01

    1.1 These test methods cover procedures for the chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade aluminum oxide and aluminum oxide-boron carbide composite pellets to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Boron by Titrimetry 7 to 13 Separation of Boron for Mass Spectrometry 14 to 19 Isotopic Composition by Mass Spectrometry 20 to 23 Separation of Halides by Pyrohydrolysis 24 to 27 Fluoride by Ion-Selective Electrode 28 to 30 Chloride, Bromide, and Iodide by Amperometric Microtitrimetry 31 to 33 Trace Elements by Emission Spectroscopy 34 to 46 1.3 The values stated in SI units are to be regarded as the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (F...

  19. Headspace solid-phase microextraction-gas chromatographic-time-of-flight mass spectrometric methodology for geographical origin verification of coffee

    International Nuclear Information System (INIS)

    Risticevic, Sanja; Carasek, Eduardo; Pawliszyn, Janusz

    2008-01-01

    Increasing consumer awareness of food safety issues requires the development of highly sophisticated techniques for the authentication of food commodities. The food products targeted for falsification are either products of high commercial value or those produced in large quantities. For this reason, the present investigation is directed towards the characterization of coffee samples according to the geographical origin. The conducted research involves the development of a rapid headspace solid-phase microextraction (HS-SPME)-gas chromatography-time-of-flight mass spectrometry (GC-TOFMS) method that is utilized for the verification of geographical origin traceability of coffee samples. As opposed to the utilization of traditional univariate optimization methods, the current study employs the application of multivariate experimental designs to the optimization of extraction-influencing parameters. Hence, the two-level full factorial first-order design aided in the identification of two influential variables: extraction time and sample temperature. The optimum set of conditions for the two variables was 12 min and 55 deg. C, respectively, as directed by utilization of Doehlert matrix and response surface methodology. The high-throughput automated SPME procedure was completed by implementing a single divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) 50/30 μm metal fiber with excellent durability properties ensuring the completion of overall sequence of coffee samples. The utilization of high-speed TOFMS instrument ensured the completion of one GC-MS run of a complex coffee sample in 7.9 min and the complete list of benefits provided by ChromaTOF software including fully automated background subtraction, baseline correction, peak find and mass spectral deconvolution algorithms was exploited during the data evaluation procedure. The combination of the retention index (RI) system using C 8 -C 40 alkanes and the mass spectral library search was utilized for the

  20. Headspace solid-phase microextraction-gas chromatographic-time-of-flight mass spectrometric methodology for geographical origin verification of coffee

    Energy Technology Data Exchange (ETDEWEB)

    Risticevic, Sanja [Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1 (Canada); Carasek, Eduardo [Department of Chemistry, Federal University of Santa Catarina, Trindade, Florianopolis, 88040-900, Santa Catarina (Brazil); Pawliszyn, Janusz [Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1 (Canada)], E-mail: janusz@uwaterloo.ca

    2008-06-09

    Increasing consumer awareness of food safety issues requires the development of highly sophisticated techniques for the authentication of food commodities. The food products targeted for falsification are either products of high commercial value or those produced in large quantities. For this reason, the present investigation is directed towards the characterization of coffee samples according to the geographical origin. The conducted research involves the development of a rapid headspace solid-phase microextraction (HS-SPME)-gas chromatography-time-of-flight mass spectrometry (GC-TOFMS) method that is utilized for the verification of geographical origin traceability of coffee samples. As opposed to the utilization of traditional univariate optimization methods, the current study employs the application of multivariate experimental designs to the optimization of extraction-influencing parameters. Hence, the two-level full factorial first-order design aided in the identification of two influential variables: extraction time and sample temperature. The optimum set of conditions for the two variables was 12 min and 55 deg. C, respectively, as directed by utilization of Doehlert matrix and response surface methodology. The high-throughput automated SPME procedure was completed by implementing a single divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) 50/30 {mu}m metal fiber with excellent durability properties ensuring the completion of overall sequence of coffee samples. The utilization of high-speed TOFMS instrument ensured the completion of one GC-MS run of a complex coffee sample in 7.9 min and the complete list of benefits provided by ChromaTOF software including fully automated background subtraction, baseline correction, peak find and mass spectral deconvolution algorithms was exploited during the data evaluation procedure. The combination of the retention index (RI) system using C{sub 8}-C{sub 40} alkanes and the mass spectral library search was

  1. Development and validation of a sensitive liquid chromatographic-tandem mass spectrometric method for the simultaneous analysis of granisetron and 7-hydroxy granisetron in human plasma and urine samples: application in a clinical pharmacokinetic study in pregnant subject.

    Science.gov (United States)

    Zhao, Yang; Chen, Hui-Jun; Caritis, Steve; Venkataramanan, Raman

    2016-02-01

    A liquid chromatography-tandem mass spectrometric method for the quantification of granisetron and its major metabolite, 7-hydroxy granisetron in human plasma and urine samples was developed and validated. Respective stable isotopically labeled granisetron and 7-hydroxy granisetron were used as internal standards (IS). Chromatography was performed using an Xselect HSS T3 analytical column with a mobile phase of 20% acetonitrile in water (containing 0.2 mM ammonium formate and 0.14% formic acid, pH 4) delivered in an isocratic mode. Tandem mass spectrometry operating in positive electrospray ionization mode with multiple reaction monitoring was used for quantification. The standard curves were linear in the concentration ranges of 0.5-100 ng/mL for granisetron and 0.1-100 ng/mL for 7-hydroxy granisetron in human plasma samples, and 2-2000 ng/mL for granisetron and 2-1000 ng/mL for 7-hydroxy granisetron in human urine samples, respectively. The accuracies were >85% and the precision as determined by the coefficient of variations was granisetron or 7-hydroxy granisetron in either plasma or urine samples. Granisetron was stable under various storage and experimental conditions. This validated method was successfully applied to a pharmacokinetic study after intravenous administration of 1 mg granisetron to a pregnant subject. Copyright © 2015 John Wiley & Sons, Ltd.

  2. Determination of polycyclic aromatic hydrocarbons and their nitrated derivatives in Diesel soot by gas chromatography and high resolution mass spectrometry

    International Nuclear Information System (INIS)

    Remberg, G.

    1998-11-01

    Periodical monitoring of the exposure levels towards chemical hazards is an important issue of occupational safety and health. Some constituents of diesel exhaust emissions, like polycyclic aromatic hydrocarbons and their nitrated derivatives, have attracted special attention due to their carcinogenic and partly mutagenic properties. Therefore, the present work focused on the development of new methodical aspects for the determination of these substances in diesel particulate matter. In the first stage of this study the essential gas chromatographic and mass spectrometric characteristics of 51 authentic PAH and NPAH single standards have been investigated. A retention index system on DB-5 type capillary columns has been established in order to facilitate the identification of these target compounds in complex matrices. Before choosing proper MID quantification ions the full scan (+)EI- and ECNCI-mass spectra of all standards were acquired. The GC-(+)EI-MS detection limits of three NPAH were determined with different mass spectrometric modes (i.e. LR/full scan, LR/MID and HR/MID), being in the range of a few picograms in the latter mode. The use of large volume injection in conjunction with a PTV for PAH/NPAH trace analysis was studied and optimized for an injection volume of up to nine microliters. Extraction of diesel soot with dichloromethane was performed in accordance with US EPA method 3545 by means of accelerated solvent extraction, which takes significantly less than one hour. Gas chromatographic investigations on such extracts with various detectors of different selectivity (i.e. FID, LRMS and HRMS) showed the exclusive capability of high mass spectral resolution (about R ∼10000) to differentiate between analytes and matrix components. On the basis of these preliminary results an operating procedure was proposed. Its key-elements are accelerated solvent extraction of the sample and analysis of the resulting solution by means of GC-(+)EI-HRMS followed by

  3. Gas chromatographic quadrupole time-of-flight full scan high resolution mass spectrometric screening of human urine in antidoping analysis

    NARCIS (Netherlands)

    Abushareeda, Wadha; Lyris, Emmanouil; Kraiem, Suhail; Wahaibi, Aisha Al; Alyazidi, Sameera; Dbes, Najib; Lommen, Arjen; Nielen, Michel; Horvatovich, Peter L.; Alsayrafi, Mohammed; Georgakopoulos, Costas

    2017-01-01

    This paper presents the development and validation of a high-resolution full scan (FS) electron impact ionization (EI) gas chromatography coupled to quadrupole Time-of-Flight mass spectrometry (GC/QTOF) platform for screening anabolic androgenic steroids (AAS) in human urine samples. The World

  4. Rapid Mass Spectrometric Analysis of a Novel Fucoidan, Extracted from the Brown Alga Coccophora langsdorfii

    Directory of Open Access Journals (Sweden)

    Stanislav D. Anastyuk

    2014-01-01

    Full Text Available The novel highly sulfated (35% fucoidan fraction Cf2 , which contained, along with fucose, galactose and traces of xylose and uronic acids was purified from the brown alga Coccophora langsdorfii. Its structural features were predominantly determined (in comparison with fragments of known structure by a rapid mass spectrometric investigation of the low-molecular-weight fragments, obtained by “mild” (5 mg/mL and “exhaustive” (maximal concentration autohydrolysis. Tandem matrix-assisted laser desorption/ionization mass spectra (MALDI-TOF/TOFMS of fucooligosaccharides with even degree of polymerization (DP, obtained by “mild” autohydrolysis, were the same as that observed for fucoidan from Fucus evanescens, which have a backbone of alternating (1 → 3- and (1 → 4 linked sulfated at C-2 and sometimes at C-4 of 3-linked α-L-Fucp residues. Fragmentation patterns of oligosaccharides with odd DP indicated sulfation at C-2 and at C-4 of (1 → 3 linked α-L-Fucp residues on the reducing terminus. Minor sulfation at C-3 was also suggested. The “exhaustive” autohydrolysis allowed us to observe the “mixed” oligosaccharides, built up of fucose/xylose and fucose/galactose. Xylose residues were found to occupy both the reducing and nonreducing termini of FucXyl disaccharides. Nonreducing galactose residues as part of GalFuc disaccharides were found to be linked, possibly, by 2-type of linkage to fucose residues and were found to be sulfated, most likely, at position C-2.

  5. Examination of segmental average mass spectra from liquid chromatography-tandem mass spectrometric (LC-MS/MS) data enables screening of multiple types of protein modifications.

    Science.gov (United States)

    Liu, Nai-Yu; Lee, Hsiao-Hui; Chang, Zee-Fen; Tsay, Yeou-Guang

    2015-09-10

    It has been observed that a modified peptide and its non-modified counterpart, when analyzed with reverse phase liquid chromatography, usually share a very similar elution property [1-3]. Inasmuch as this property is common to many different types of protein modifications, we propose an informatics-based approach, featuring the generation of segmental average mass spectra ((sa)MS), that is capable of locating different types of modified peptides in two-dimensional liquid chromatography-mass spectrometric (LC-MS) data collected for regular protease digests from proteins in gels or solutions. To enable the localization of these peptides in the LC-MS map, we have implemented a set of computer programs, or the (sa)MS package, that perform the needed functions, including generating a complete set of segmental average mass spectra, compiling the peptide inventory from the Sequest/TurboSequest results, searching modified peptide candidates and annotating a tandem mass spectrum for final verification. Using ROCK2 as an example, our programs were applied to identify multiple types of modified peptides, such as phosphorylated and hexosylated ones, which particularly include those peptides that could have been ignored due to their peculiar fragmentation patterns and consequent low search scores. Hence, we demonstrate that, when complemented with peptide search algorithms, our approach and the entailed computer programs can add the sequence information needed for bolstering the confidence of data interpretation by the present analytical platforms and facilitate the mining of protein modification information out of complicated LC-MS/MS data. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Mass spectrometric analysis of protein interactions

    DEFF Research Database (Denmark)

    Borch, Jonas; Jørgensen, Thomas J. D.; Roepstorff, Peter

    2005-01-01

    Mass spectrometry is a powerful tool for identification of interaction partners and structural characterization of protein interactions because of its high sensitivity, mass accuracy and tolerance towards sample heterogeneity. Several tools that allow studies of protein interaction are now...... available and recent developments that increase the confidence of studies of protein interaction by mass spectrometry include quantification of affinity-purified proteins by stable isotope labeling and reagents for surface topology studies that can be identified by mass-contributing reporters (e.g. isotope...... labels, cleavable cross-linkers or fragment ions. The use of mass spectrometers to study protein interactions using deuterium exchange and for analysis of intact protein complexes recently has progressed considerably....

  7. Gas chromatographic quadrupole time-of-flight full scan high resolution mass spectrometric screening of human urine in antidoping analysis

    NARCIS (Netherlands)

    Abushareeda, Wadha; Lyris, Emmanouil; Kraiem, Suhail; Wahaibi, Aisha Al; Alyazidi, Sameera; Dbes, Najib; Lommen, Arjen; Nielen, Michel; Horvatovich, Peter L.; Alsayrafi, Mohammed; Georgakopoulos, Costas

    2017-01-01

    This paper presents the development and validation of a high-resolution full scan (FS) electron impact ionization (EI) gas chromatography coupled to quadrupole Time-of-Flight mass spectrometry (GC/QTOF) platform for screening anabolic androgenic steroids (AAS) in human urine samples. The World

  8. A Multifaceted Mass Spectrometric Method to Probe Feeding Related Neuropeptide Changes in Callinectes sapidus and Carcinus maenas

    Science.gov (United States)

    Zhang, Yuzhuo; DeLaney, Kellen; Hui, Limei; Wang, Junhua; Sturm, Robert M.; Li, Lingjun

    2018-05-01

    Food intake is regulated by various neuromodulators, including numerous neuropeptides. However, it remains elusive at the molecular and cellular level as to how these important chemicals regulate internal processes and which regions of the neuronal organs are responsible for regulating the behavior. Here we report a comparative neuropeptidomic analysis of the brain and pericardial organ (PO) in response to feeding in two well-studied crustacean physiology model organisms, Callinectes sapidus and Carcinus maenas, using mass spectrometry (MS) techniques. A multifaceted MS-based approach has been developed to obtain complementary information on the expression changes of a large array of neuropeptides in the brain and PO. The method employs stable isotope labeling of brain and PO extracts for relative MS quantitation, capillary electrophoresis (CE)-MS for fractionation and high-specificity analysis, and mass spectrometric imaging (MSI) for in-situ molecular mapping of peptides. A number of neuropeptides, including RFamides, B-type allatostatins (AST-B), RYamides, and orcokinins exhibit significant changes in abundance after feeding in this investigation. Peptides from the AST-B family found in PO tissue were shown to have both altered expression and localization changes after feeding, indicating that they may be a class of vital neuropeptide regulators involved in feeding behavior. [Figure not available: see fulltext.

  9. A Multifaceted Mass Spectrometric Method to Probe Feeding Related Neuropeptide Changes in Callinectes sapidus and Carcinus maenas

    Science.gov (United States)

    Zhang, Yuzhuo; DeLaney, Kellen; Hui, Limei; Wang, Junhua; Sturm, Robert M.; Li, Lingjun

    2018-02-01

    Food intake is regulated by various neuromodulators, including numerous neuropeptides. However, it remains elusive at the molecular and cellular level as to how these important chemicals regulate internal processes and which regions of the neuronal organs are responsible for regulating the behavior. Here we report a comparative neuropeptidomic analysis of the brain and pericardial organ (PO) in response to feeding in two well-studied crustacean physiology model organisms, Callinectes sapidus and Carcinus maenas, using mass spectrometry (MS) techniques. A multifaceted MS-based approach has been developed to obtain complementary information on the expression changes of a large array of neuropeptides in the brain and PO. The method employs stable isotope labeling of brain and PO extracts for relative MS quantitation, capillary electrophoresis (CE)-MS for fractionation and high-specificity analysis, and mass spectrometric imaging (MSI) for in-situ molecular mapping of peptides. A number of neuropeptides, including RFamides, B-type allatostatins (AST-B), RYamides, and orcokinins exhibit significant changes in abundance after feeding in this investigation. Peptides from the AST-B family found in PO tissue were shown to have both altered expression and localization changes after feeding, indicating that they may be a class of vital neuropeptide regulators involved in feeding behavior. [Figure not available: see fulltext.

  10. Mass spectrometrical study of rare gas compositions and neutron capture effects in Yamato-74191 (L 3) Chondrite

    International Nuclear Information System (INIS)

    Takaoka, N.; Nagao, K.

    1980-01-01

    The unequilibrated hypersthene chondrite Yamato-74191 was studied mass spectrometrically for rare gases released at various temperatures. Cosmogenic gases dominate in He and Ne. The meteorite contains large amounts of trapped Ar, Kr and Xe, and radiogenic 40 Ar and 129 Xe. Cosmic-ray irradiation and K-Ar ages were determined. In addition to spallogenic components of Kr and Xe, isotopic excesses of 8 sup(O)Kr, 82 Kr, 128 Xe and 126 Xe relative to AVCC-Kr and -Xe were found. The ratio of 80 Kr-excess to 82 Kr-excess is 2.66 after correction for spallogenic Kr. A correlation between 128 Xe/ 132 Xe and 129 Xe/ 132 Xe was found. The 129 Xe/ 132 Xe ratio for trapped Xe in Yamato-74191 was determined as 1.12 +- 0.29 with the correlation plot. The excesses found in Yamato-74191 are best explained by epithermal neutron capture on Br and I, and by the 127 I(n,2nβ) 126 Xe reaction. Using neutron-produced 80 Kr, the neutron slowing-down density was estimated to be 0.14 +- 0.03 cm -3 sec -1 . A minimum mass and a preatmospheric radius was estimated to be 470 kg and 32 cm, respectively. (orig.)

  11. Thermal ionisation mass spectrometry (TIMS): what, how and why?

    International Nuclear Information System (INIS)

    Aggarwal, S.K.

    2002-01-01

    Thermal ionisation mass spectrometry (TIMS) is one of the oldest mass spectrometric techniques, which has been used for determining the isotopic composition and concentration of different elements using isotope dilution. In spite of the introduction of many other inorganic mass spectrometric techniques like spark source mass spectrometry (SSMS), glow discharge mass spectrometry (GDMS), inductively coupled plasma-mass spectrometry (ICP-MS), secondary ion mass spectrometry (SIMS), the TIMS technique plays the role of a definitive analytical methodology and still occupies a unique position in terms of its capabilities with respect to precision and accuracy as well as sensitivity

  12. Monitoring the on-surface synthesis of graphene nanoribbons by mass spectrometry

    KAUST Repository

    Zhang, Wen

    2017-06-14

    We present a mass spectrometric approach to monitor and characterize the intermediates of graphene nanoribbon (GNR) formation by chemical vapor deposition (CVD) on top of Au(111) surfaces. Information regarding the repeating units, lengths, and termini can be obtained directly from the surface sample by a modified matrix assisted laser desorption/ionization (MALDI) method. The mass spectrometric results reveal ample oxidative side reactions under CVD conditions which can, however, be diminished drastically by introduction of protective H2 gas at ambient pressure. Simultaneously, addition of hydrogen extends the lengths of the oligophenylenes and thus the final GNRs. Moreover, the prematurely formed cyclodehydrogenation products during the oligomer growth can be assigned by the mass spectrometric method. The obtained mechanistic insights provide valuable information for optimizing and upscaling the bottom-up fabrication of GNRs. Given the important role of GNRs as semiconductors, the mass spectrometric characterization provides a readily available tool to improve and characterize their structural perfection.

  13. Detecting pM concentrations of prostaglandins in cell culture supernatants by capillary SCX-LC-MS/MS

    DEFF Research Database (Denmark)

    Dahl, Sandra Rinne; Kleiveland, Charlotte Ramstad; Kassem, Moustapha

    2008-01-01

    A highly sensitive, improved online strong cation exchange (SCX)--RP capillary liquid chromatographic (cLC) method with IT mass spectrometric (IT-MS/MS) detection for the simultaneous determination of prostaglandin (PG)A(1), PGD(2), PGE(1), PGE(2), PGF(2alpha), 8-iso-(8i)PGF(2alpha), 6-keto-(6k...

  14. The application study on the prospecting for gold by car-borne gamma-ray spectrometric method in northern Hebei and other areas

    International Nuclear Information System (INIS)

    Ma Zhongxiang; Liu Tengyao; Zhang Peng; Lu Shili; Zhai Yugui; Ma Yanfang

    1995-01-01

    The prospecting method for gold by car-borne gamma-ray spectrometric survey is a new geophysical and geochemical technique in the search for concealed gold deposits which can be used to effectively predict the regional gold metallogenetic potential area. The method of car-borne gamma-ray spectrometric survey was adopted and 63416 data at gamma-ray spectrometric measuring sites from rock masses (or strata) in northern Hebei and other areas (49100 km 2 ) are obtained. On the basis of the size of geological bodies, the sliding filtering technique was applied to process the gamma-ray spectrometric data from regional geological bodies and maps showing the parameter distribution characteristics were plotted (11 sheets). In accordance with the thorough on the distribution characteristics of gamma-ray spectrometric parameters that reflect the regional geological environment of gold metallogenesis, a set of gamma-ray spectrometric combination parameters in correlation with regional gold metallogenesis has been established and the characteristic information of gamma-ray spectrometric parameters has been extracted. Combined with geological information, the gold metallogenetic geological environment in the working area was studied, and two potential areas were predicted. After verification, gold mineralization was encountered in some areas. The study results show that the car-borne gamma-ray spectrometric method used for regional gold prospecting is a rapid, economical and effective one

  15. Extraction estimation and gas chromatographic mass spectrometric analysis of the non polar fraction of the pistia stratiotes

    International Nuclear Information System (INIS)

    Hussain, Z.

    2013-01-01

    The non-polar compounds of the Pistia stratiotes were extracted using n-hexane as solvent. The extraction yields were determined both for the cold and hot extraction procedure as 8.50 +- 0.05% and 12.00 +- 0.05%, respectively. The extract was analyzed and separated into its components using GC equipped with FID and GC mass in separate experiments. The most important compounds identified in n-hexane extract of leaves of P. stratiotes are long chain compound of the nitrogenous nature and oxygenated compounds of mixed functional groups. The antibacterial activity of this fraction was investigated against eight pathogenic bacteria using disc diffusion method. Larger zones of inhibition were observed for Bacillus subtilis, Pseudomonas aeruginosa and Agrobacterium tumefaciens as compared to Klebsiella pneumoniaee and Staphylococcus aureus where the activity was relatively less. No activity was observed against Escherichia coli, Salmonella typhi and Bacillus atrophaeus. (author)

  16. Quantitative analysis of oxytetracycline and its impurities by LC-MS-MS

    DEFF Research Database (Denmark)

    Lykkeberg, Anne Kruse; Halling-Sørensen, Bent; Cornett, Claus

    2004-01-01

    A liquid chromatographic-tandem mass spectrometric method using an Xterra MS C(18) chromatographic column ( 100 mm x 2.1 mm i.d., 3.5microm) that allows complete separation of oxytetracycline (OTC) and the impurities: 4-epi-oxytetracycline (EOTC), tetracycline (TC), 4-epi-tetracycline (ETC), 2......-acetyl-2-decarboxamido-oxytetracycline (ADOTC), alpha-apo-oxytetracycline (alpha-AOTC) and beta-apo-oxytetracycline (beta-AOTC) was developed. Gradient elution was used and calibration curves were obtained using the scan mode selected reaction monitoring (SRM). Acceptable correlations were obtained...

  17. Automated on-line liquid–liquid extraction system for temporal mass spectrometric analysis of dynamic samples

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Kai-Ta; Liu, Pei-Han [Department of Applied Chemistry, National Chiao Tung University, 1001 University Rd, Hsinchu, 300, Taiwan (China); Urban, Pawel L. [Department of Applied Chemistry, National Chiao Tung University, 1001 University Rd, Hsinchu, 300, Taiwan (China); Institute of Molecular Science, National Chiao Tung University, 1001 University Rd, Hsinchu, 300, Taiwan (China)

    2015-09-24

    Most real samples cannot directly be infused to mass spectrometers because they could contaminate delicate parts of ion source and guides, or cause ion suppression. Conventional sample preparation procedures limit temporal resolution of analysis. We have developed an automated liquid–liquid extraction system that enables unsupervised repetitive treatment of dynamic samples and instantaneous analysis by mass spectrometry (MS). It incorporates inexpensive open-source microcontroller boards (Arduino and Netduino) to guide the extraction and analysis process. Duration of every extraction cycle is 17 min. The system enables monitoring of dynamic processes over many hours. The extracts are automatically transferred to the ion source incorporating a Venturi pump. Operation of the device has been characterized (repeatability, RSD = 15%, n = 20; concentration range for ibuprofen, 0.053–2.000 mM; LOD for ibuprofen, ∼0.005 mM; including extraction and detection). To exemplify its usefulness in real-world applications, we implemented this device in chemical profiling of pharmaceutical formulation dissolution process. Temporal dissolution profiles of commercial ibuprofen and acetaminophen tablets were recorded during 10 h. The extraction-MS datasets were fitted with exponential functions to characterize the rates of release of the main and auxiliary ingredients (e.g. ibuprofen, k = 0.43 ± 0.01 h{sup −1}). The electronic control unit of this system interacts with the operator via touch screen, internet, voice, and short text messages sent to the mobile phone, which is helpful when launching long-term (e.g. overnight) measurements. Due to these interactive features, the platform brings the concept of the Internet-of-Things (IoT) to the chemistry laboratory environment. - Highlights: • Mass spectrometric analysis normally requires sample preparation. • Liquid–liquid extraction can isolate analytes from complex matrices. • The proposed system automates

  18. Automated on-line liquid–liquid extraction system for temporal mass spectrometric analysis of dynamic samples

    International Nuclear Information System (INIS)

    Hsieh, Kai-Ta; Liu, Pei-Han; Urban, Pawel L.

    2015-01-01

    Most real samples cannot directly be infused to mass spectrometers because they could contaminate delicate parts of ion source and guides, or cause ion suppression. Conventional sample preparation procedures limit temporal resolution of analysis. We have developed an automated liquid–liquid extraction system that enables unsupervised repetitive treatment of dynamic samples and instantaneous analysis by mass spectrometry (MS). It incorporates inexpensive open-source microcontroller boards (Arduino and Netduino) to guide the extraction and analysis process. Duration of every extraction cycle is 17 min. The system enables monitoring of dynamic processes over many hours. The extracts are automatically transferred to the ion source incorporating a Venturi pump. Operation of the device has been characterized (repeatability, RSD = 15%, n = 20; concentration range for ibuprofen, 0.053–2.000 mM; LOD for ibuprofen, ∼0.005 mM; including extraction and detection). To exemplify its usefulness in real-world applications, we implemented this device in chemical profiling of pharmaceutical formulation dissolution process. Temporal dissolution profiles of commercial ibuprofen and acetaminophen tablets were recorded during 10 h. The extraction-MS datasets were fitted with exponential functions to characterize the rates of release of the main and auxiliary ingredients (e.g. ibuprofen, k = 0.43 ± 0.01 h"−"1). The electronic control unit of this system interacts with the operator via touch screen, internet, voice, and short text messages sent to the mobile phone, which is helpful when launching long-term (e.g. overnight) measurements. Due to these interactive features, the platform brings the concept of the Internet-of-Things (IoT) to the chemistry laboratory environment. - Highlights: • Mass spectrometric analysis normally requires sample preparation. • Liquid–liquid extraction can isolate analytes from complex matrices. • The proposed system automates the

  19. Mass spectrometric investigation of neutral and charged constituents in saturated vapor over PrI3

    International Nuclear Information System (INIS)

    Motalov, V.B.; Vorobiev, D.E.; Kudin, L.S.; Markus, T.

    2009-01-01

    The Knudsen effusion mass spectrometric technique was used to study vapor species over praseodymium triiodide. The monomer, PrI 3 , and dimer, Pr 2 I 6 , molecules and the negative ions, PrI 4 - and Pr 2 I 7 - , were observed in saturated vapor in the temperature range from 856 K to 1048 K. The partial vapor pressures of neutral constituents were determined and the enthalpies of sublimation obtained using the second and the third laws of thermodynamics (Δ s H deg. (298.15 K) = 291 ± 4 kJ mol -1 for PrI 3 , and Δ s H deg. (298.15 K) = 400 ± 30 kJ mol -1 for Pr 2 I 6 ). The equilibrium constants for various ion molecular reactions were measured and the enthalpies of reactions obtained. The enthalpies of formation, Δ f H deg. (298.15 K) kJ mol -1 , of gaseous molecules and ions were calculated and are as follows: -374 ± 6 (PrI 3 ), -929 ± 30 (Pr 2 I 6 ), -867 ± 30 (PrI 4 - ), -1432 ± 50 (Pr 2 I 7 - )

  20. Standard test methods for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade uranyl nitrate solutions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 These test methods cover procedures for the chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade uranyl nitrate solution to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Determination of Uranium 7 Specific Gravity by Pycnometry 15-20 Free Acid by Oxalate Complexation 21-27 Determination of Thorium 28 Determination of Chromium 29 Determination of Molybdenum 30 Halogens Separation by Steam Distillation 31-35 Fluoride by Specific Ion Electrode 36-42 Halogen Distillate Analysis: Chloride, Bromide, and Iodide by Amperometric Microtitrimetry 43 Determination of Chloride and Bromide 44 Determination of Sulfur by X-Ray Fluorescence 45 Sulfate Sulfur by (Photometric) Turbidimetry 46 Phosphorus by the Molybdenum Blue (Photometric) Method 54-61 Silicon by the Molybdenum Blue (Photometric) Method 62-69 Carbon by Persulfate Oxidation-Acid Titrimetry 70 Conversion to U3O8 71-74 Boron by ...

  1. Direct analysis of samples by mass spectrometry: From elements to bio-molecules using laser ablation inductively couple plasma mass spectrometry and laser desorption/ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Perdian, David C. [Iowa State Univ., Ames, IA (United States)

    2009-01-01

    Mass spectrometric methods that are able to analyze solid samples or biological materials with little or no sample preparation are invaluable to science as well as society. Fundamental research that has discovered experimental and instrumental parameters that inhibit fractionation effects that occur during the quantification of elemental species in solid samples by laser ablation inductively coupled plasma mass spectrometry is described. Research that determines the effectiveness of novel laser desorption/ionization mass spectrometric methods for the molecular analysis of biological tissues at atmospheric pressure and at high spatial resolution is also described. A spatial resolution is achieved that is able to analyze samples at the single cell level.

  2. Chemometric strategy for automatic chromatographic peak detection and background drift correction in chromatographic data.

    Science.gov (United States)

    Yu, Yong-Jie; Xia, Qiao-Ling; Wang, Sheng; Wang, Bing; Xie, Fu-Wei; Zhang, Xiao-Bing; Ma, Yun-Ming; Wu, Hai-Long

    2014-09-12

    Peak detection and background drift correction (BDC) are the key stages in using chemometric methods to analyze chromatographic fingerprints of complex samples. This study developed a novel chemometric strategy for simultaneous automatic chromatographic peak detection and BDC. A robust statistical method was used for intelligent estimation of instrumental noise level coupled with first-order derivative of chromatographic signal to automatically extract chromatographic peaks in the data. A local curve-fitting strategy was then employed for BDC. Simulated and real liquid chromatographic data were designed with various kinds of background drift and degree of overlapped chromatographic peaks to verify the performance of the proposed strategy. The underlying chromatographic peaks can be automatically detected and reasonably integrated by this strategy. Meanwhile, chromatograms with BDC can be precisely obtained. The proposed method was used to analyze a complex gas chromatography dataset that monitored quality changes in plant extracts during storage procedure. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Dual liquid and gas chromatograph system

    Science.gov (United States)

    Gay, D.D.

    A chromatographic system is described that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a nontransparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extreme low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.

  4. Spectrometric methods for the determination of chlorine in crude oil and petroleum derivatives — A review

    International Nuclear Information System (INIS)

    Doyle, Adriana; Saavedra, Alvaro; Tristão, Maria Luiza B.; Mendes, Luiz A.N.; Aucélio, Ricardo Q.

    2013-01-01

    Chlorine determination in crude oil is made in order to guarantee that the oil does not contain levels of this element that might cause damages in the oil processing equipment. In petroleum products, the determination of chlorine is made, for instance, to evaluate if there are proper concentrations of organochloride compounds, which are used as additives. Such determinations are currently performed following official guidelines from the ASTM International and from the United States Environmental Protection Agency as well as protocols indicated by the Universal Oil Products. X-ray fluorescence spectroscopy plays an important role in many of these official methods. In contrast, other spectrometric methods based on optical and mass detection are plagued by limitations related to both the fundamental characteristics of non-metals and to the complex sample matrices, which reflects in the small number of articles devoted to these applications. In this review, the current status of the spectrometric methods, especially the role played by X-ray fluorescence spectrometry, is evaluated in terms of the determination of chlorine in crude oil and petroleum derivatives. Comparison of the performance of the methods, limitations and potential new approaches to ensure proper spectrometric determinations of chlorine is indicated. - Highlights: • Critical evaluation of spectrometric methods for chlorine in petroleum products. • Reviews on element determination in petroleum have not address the case of chlorine. • Peculiarities of the spectrometric determination of Cl in petroleum are discussed. • The spectrometric approaches are detailed and compared to the official methods. • New trends in chlorine determination in petroleum products are indicated

  5. New approach to the characterization of pyrolysis coal products by gas chromatography mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Cappiello, A.; Mangani, F.; Bruner, F.; Bonfanti, L. [University of Urbino, Urbino (Italy)

    1996-06-07

    A method for the characterization of coal thermal behaviour, based on gas chromatographic-mass spectrometric analysis of the pyrolysate, is presented. Twelve different coal samples representative of the entire coal rank, were selected. The pyrolysis products, obtained at 800{degree}C, were first collected and then analysed in two GC-MS systems. The sampling apparatus consisted of three different traps in order to separate the products into three fractions on the basis of their volatility. The GC-MS analysis was also arranged according to this criterion. A packed column, coupled to a double-focusing magnetic mass spectrometer, was used for the volatile fractions of the pyrolysate and a capillary column, coupled to a quadruple analyser, was employed for the analysis of the condensed fraction. Sampling and analysis procedures were carried out separately, thus allowing careful optimization of the strategy for the characterization of the pyrolysate. The condensate was analysed in the selected-ion monitoring mode for the determination of different classes of compounds. Some evaluations and comparisons, extrapolated from the results obtained, are presented.

  6. A comparative study of carbocyanine dyes measured with TOF-SIMS and other mass spectrometric techniques

    International Nuclear Information System (INIS)

    Adriaensen, L.; Vangaever, F.; Gijbels, R.

    2004-01-01

    A series of cationic, zwitterionic and anionic carbocyanine dyes have been measured with TOF-SIMS under Ga + bombardment. In contrast to the cationic dyes, which give very intense molecular ion and characteristic fragment signals in the positive mode, the anionic dyes produce only a few fragment signals of low intensity. Even in the negative mode no molecular ions of the anionic dyes are seen in the recorded spectra. Actually, none of the studied molecules produces negative SIMS spectra containing molecular information. A comparative study was made between TOF-SIMS and other mass spectrometric techniques, namely, fast atom bombardment (FAB), electro spray ionization (ESI) and matrix assisted laser desorption ionization (MALDI). The measurements show that MALDI, ESI as well as FAB all give rise to spectra containing molecular ion signals, either in the positive, in the negative or in both modes. Unlike with TOF-SIMS, this observation also applies to the anionic dyes. Characteristic fragments of the dyes are present in all the recorded spectra. However, TOF-SIMS appears to induce more fragment ions in comparison with the other techniques. ESI, for instance, produces hardly any molecular fragments. Finally, the kind of fragment ions recorded depends upon the technique used, though some signals are produced by various techniques. For these carbocyanine dyes there is no clear correlation between the mass spectra obtained with TOF-SIMS and spectra obtained with the other techniques. This points to different desorption/ionization mechanisms, and makes it difficult, in practice, to make predictions on the feasibility of TOF-SIMS, starting from results of the other MS techniques

  7. NZG 201 portable spectrometric unit

    International Nuclear Information System (INIS)

    Jursa, P.; Novakova, O.; Slezak, V.

    The NZG 201 spectrometric unit is a portable single-channel processing unit supplied from the mains or a battery which allows the qualitative and quantitative measurement of different types of ionizing radiation when connected to a suitable detection unit. The circuit layout and the choice of control elements makes the spectrometric unit suitable for use with scintillation detector units. The spectrometric unit consists of a pulse amplifier, an amplitude pulse analyzer, a pulse counter, a pulse rate counter with an output for a recorder, a high voltage source and a low voltage source. The block diagram is given. All circuits are modular and are mounted on PCB's. The apparatus is built in a steel cabinet with a raised edge which protects the control elements. The linear pulse amplifier has a maximum gain of 1024, the pulse counter has a maximum capacity of 10 6 -1 imp and time resolution better than 0.5 μs. The temperature interval at which the apparatus is operational is 0 to 45 degC, its weight is 12.5 kg and dimensions 36x280x310 mm, energy range O.025 to 2.5 MeV, for 137 Cs the energy resolution is 8 to 10%. The spectrometric unit NZG 2O1 may, with regard to its parameters, number and range of control elements, be used as a universal measuring unit. (J.P.)

  8. Gas chromatographic-mass spectrometric investigation of n-alkanes and carboxylic acids in bottom sediments of the northern Caspian Sea

    Science.gov (United States)

    Kenzhegaliev, Akimgali; Zhumagaliev, Sagat; Kenzhegalieva, Dina; Orazbayev, Batyr

    2018-03-01

    Prior to the start of experimental oil production in the Kashagan field (northern part of the Caspian Sea), n-alkanes and carboxylic acids contained in samples obtained from bottom sediments in the area of artificial island "D" were investigated by gas chromatography-mass spectrometry. Concentrations of 10 n-alkanes (composed of C10-C13, C15-C20) and 11 carboxylic acids (composed of C6-C12, C14-C16) were identified and measured. Concentrations of individual alkanes and carboxylic acids in bottom sediments of the various samples varied between 0.001 ÷ 0.88 μg/g and 0.001 ÷ 1.94 μg/g, respectively. Mass spectra, in particular the M+ molecular ion peak and the most intense peaks of fragment ions, are given. The present study illustrates the stability of molecular ions to electronic ionisation and the main fragment ions to the total ion current and shows that the initial fragmentation of alkanes implies radical cleavage of C2H5 rather than CH3. All aliphatic monocarboxylic acids studied were characterised by McLafferty rearrangement leading to the formation of F4 cation-radical with m/z 60 and F3 cation-radical with m/z 88 in the case of ethylhexanoic acid. The formation of oxonium ions presents another important aspect of acid fragmentation. Using mass numbers of oxonium ions and rearrangement ions allows determination of the substitution character in α- and β- C atoms. The essence of our approach is to estimate the infiltration of hydrocarbon fluids from the enclosing formation into sea water, comprising an analysis of derivatives of organic compounds in bottom sediments. Thus, concentrations of derived organic molecules can serve as a basis for estimates of the depth at which hydrocarbon fluids leak, i.e., to serve as an auxiliary technique in the search for hydrocarbon deposits and to repair well leaks.

  9. Novel Selectivity-Based Forensic Toxicological Validation of a Paper Spray Mass Spectrometry Method for the Quantitative Determination of Eight Amphetamines in Whole Blood

    Science.gov (United States)

    Teunissen, Sebastiaan F.; Fedick, Patrick W.; Berendsen, Bjorn J. A.; Nielen, Michel W. F.; Eberlin, Marcos N.; Graham Cooks, R.; van Asten, Arian C.

    2017-12-01

    Paper spray tandem mass spectrometry is used to identify and quantify eight individual amphetamines in whole blood in 1.3 min. The method has been optimized and fully validated according to forensic toxicology guidelines, for the quantification of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxy- N-methylamphetamine (MDMA), 3,4-methylenedioxy- N-ethylamphetamine (MDEA), para-methoxyamphetamine (PMA), para-methoxymethamphetamine (PMMA), and 4-fluoroamphetamine (4-FA). Additionally, a new concept of intrinsic and application-based selectivity is discussed, featuring increased confidence in the power to discriminate the amphetamines from other chemically similar compounds when applying an ambient mass spectrometric method without chromatographic separation. Accuracy was within ±15% and average precision was better than 15%, and better than 20% at the LLOQ. Detection limits between 15 and 50 ng/mL were obtained using only 12 μL of whole blood. [Figure not available: see fulltext.

  10. A liquid chromatography-mass spectrometry method based on class characteristic fragmentation pathways to detect the class of indole-derivative synthetic cannabinoids in biological samples.

    Science.gov (United States)

    Mazzarino, Monica; de la Torre, Xavier; Botrè, Francesco

    2014-07-21

    This article describes a liquid chromatographic/tandem mass spectrometric method, based on the use of precursor ion scan as the acquisition mode, specifically developed to detect indole-derived cannabinoids (phenylacetylindoles, naphthoylindoles and benzoylindoles) in biological fluids (saliva, urine and blood). The method is designed to recognize one or more common "structural markers", corresponding to mass spectral fragments originating from the specific portion of the molecular structure that is common to the aminoalkylindole analogues and that is fundamental for their pharmacological classification. As such, the method is also suitable for detecting unknown substances, provided they contain the targeted portion of the molecular structure. The pre-treatment procedure consists in a liquid/liquid extraction step carried out at neutral pH: this is the only pretreatment in the case of analyses carried out in saliva, while it follows an enzymatic hydrolysis procedure in the case of urine samples, or a protein precipitation step in the case of blood samples. The chromatographic separation is achieved using an octadecyl reverse-phase 5 μm fused-core particle column; while the mass spectrometric detection is carried out by a triple-quadrupole instrument in positive electrospray ionization and precursor ion scan as acquisition mode, selecting, as mass spectral fragments, the indole (m/z 144), the carbonylnaphthalenyl (m/z 155) and the naphthalenyl (m/z 127) moieties. Once developed and optimized, the analytical procedure was validated in term of sensitivity (lower limits of detection in the range of 0.1-0.5 ng mL(-1)), specificity (no interference was detected at the retention times of the analytes under investigation), recovery (higher than 65% with a satisfactory repeatability: CV% lower than 10), matrix effect (lower than 30% for all the biological specimens tested), repeatability of the retention times (CV% lower than 0.1), robustness, and carry over (the positive

  11. Mass spectrometer introduction line: application to the analysis of impurities in uranium hexafluoride; Ligne d'introduction pour spectrometre de masse: application a l'analyse des impuretes contenues dans l'UF{sub 6}

    Energy Technology Data Exchange (ETDEWEB)

    Besson, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires. Departement de physico-chimie, service des isotopes stables, section de spectrometrie de masse

    1967-01-01

    The continuous mass-spectrometric analysis of impurities in UF{sub 6} is possible industrially if certain conditions imposed by the nature of the gas are respected. The gas introduction line arriving at the spectrometer's source makes it possible to fix the flow-rate, to control the inlet pressure and to selectively destroy the gas containing the impurities. The operational conditions for the line are defined and a description is given of the theoretical and experimental study of the various elements of which it is composed, i.e. the leak valve, the flow-meter, the chemical trap and the servo-mechanism making it possible to regulate and control the gas flow. The dynamic characteristics of the line's various components and the performance of the equipment in the case of the analyses considered are given. (author) [French] L'analyse en continu par spectrometrie de masse des impuretes contenus dans l'UF{sub 6} est possible industriellement moyennant certaines conditions imposees par la nature du gaz. La ligne d'introduction des gaz dans la source du spectrometre permet de regler le debit, de controler la pression d'introduction et de detruire selectivement le gaz porteur d'impuretes. Les conditions de fonctionnement de la ligne etant definies, on decrit l'etude theorique et experimentale des differents elements qui la composent, c'est-a-dire: le robinet a fuite, le debitmetre, le piege chimique et l'ensemble d'asservissement permettant la regulation et le controle du debit. On donne les caracteristiques dynamiques des differents constituants de la ligne et les performances de l'ensemble pour les analyses considerees. (auteur)

  12. Advances in ultrasensitive mass spectrometry of organic molecules.

    Science.gov (United States)

    Kandiah, Mathivathani; Urban, Pawel L

    2013-06-21

    Ultrasensitive mass spectrometric analysis of organic molecules is important for various branches of chemistry, and other fields including physics, earth and environmental sciences, archaeology, biomedicine, and materials science. It finds applications--as an enabling tool--in systems biology, biological imaging, clinical analysis, and forensics. Although there are a number of technical obstacles associated with the analysis of samples by mass spectrometry at ultratrace level (for example analyte losses during sample preparation, insufficient sensitivity, ion suppression), several noteworthy developments have been made over the years. They include: sensitive ion sources, loss-free interfaces, ion optics components, efficient mass analyzers and detectors, as well as "smart" sample preparation strategies. Some of the mass spectrometric methods published to date can achieve sensitivity which is by several orders of magnitude higher than that of alternative approaches. Femto- and attomole level limits of detection are nowadays common, while zepto- and yoctomole level limits of detection have also been reported. We envision that the ultrasensitive mass spectrometric assays will soon contribute to new discoveries in bioscience and other areas.

  13. NICHD Biomedical Mass Spectrometry Core Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The NICHD Biomedical Mass Spectrometry Core Facility was created under the auspices of the Office of the Scientific Director to provide high-end mass-spectrometric...

  14. Analysis of selenium in body fluids: A review

    International Nuclear Information System (INIS)

    Alaejos, M.S.; Romero, C.D.

    1995-01-01

    This article reviews numerous analytical techniques for determining trace amounts of selenium in body fluids. In addition, sampling storage and treatment procedures are evaluated. The analytical techniques reviewed include the following: spectrofluorometry and spectrophotometry; atomic absorption spectrometry; fluorescence and atomic emission spectroscopy; mass spectroscopy; X-ray spectrometric analysis; neutron activation analysis; chromatographic methods; and electrochemical methods. 469 refs

  15. Determination of Low Concentrations of Acetochlor in Water by Automated Solid-Phase Extraction and Gas Chromatography with Mass-Selective Detection

    Science.gov (United States)

    Lindley, C.E.; Stewart, J.T.; Sandstrom, M.W.

    1996-01-01

    A sensitive and reliable gas chromatographic/mass spectrometric (GC/MS) method for determining acetochlor in environmental water samples was developed. The method involves automated extraction of the herbicide from a filtered 1 L water sample through a C18 solid-phase extraction column, elution from the column with hexane-isopropyl alcohol (3 + 1), and concentration of the extract with nitrogen gas. The herbicide is quantitated by capillary/column GC/MS with selected-ion monitoring of 3 characteristic ions. The single-operator method detection limit for reagent water samples is 0.0015 ??g/L. Mean recoveries ranged from about 92 to 115% for 3 water matrixes fortified at 0.05 and 0.5 ??g/L. Average single-operator precision, over the course of 1 week, was better than 5%.

  16. Comparison of various liquid chromatographic methods involving UV and atmospheric pressure chemical ionization mass spectrometric detection for the efficient trace analysis of phenylurea herbicides in various types of water samples.

    Science.gov (United States)

    van der Heeft, E; Dijkman, E; Baumann, R A; Hogendoorn, E A

    2000-05-19

    The performance of mass spectrometric (MS) detection and UV detection in combination with reversed-phase liquid chromatography without and with the use of coupled column RPLC (LC-LC) has been compared for the trace analysis of phenylurea herbicides in environmental waters. The selected samples of this comparative study originated from an inter-laboratory study. For both detection modes, a 50 mm x 4.6 mm I.D. column and a 100 mm x 4.6 mm I.D. column packed with 3 microm C18 were used as the first (C-1) and second (C-2) column, respectively. Atmospheric pressure chemical ionization mass spectrometry was performed on a magnetic sector instrument. The LC-LC-MS analysis was carried out on-line by means of direct large volume (11.7 ml) injection (LVI). The performance of both on-line (LVI, 4 ml of sample) and off-line LC-LC-UV (244 nm) analysis was investigated. The latter procedure consisted of a solid-phase extraction (SPE) of 250 ml of water sample on a 500 mg C18 cartridge. The comparative study showed that LC-LC-MS is more selective then LC-LC-UV and, in most cases, more sensitive. The LVI-LC-LC-MS approach combines direct quantification and confirmation of most of the analytes down to a level of 0.01 microg/l in water samples in less then 30 min. As regards LC-LC-UV, the off-line method appeared to be a more viable approach in comparison with the on-line procedure. This method allows the screening of phenylurea's in various types of water samples down to a level of at least 0.05 microg/l. On-line analysis with LVI provided marginal sensitivity (limits of detection of about 0.1 microg/l) and selectivity was sometimes less in case of surface water samples. Both the on-line LVI-LC-LC-MS method and the LC-LC-UV method using off-line SPE were validated by analysing a series of real-life reference samples. These samples were part of an inter-laboratory test and contained residues of herbicides ranging from 0.02 to 0.8 microg/l. Beside good correlation between the methods

  17. A rapid and sensitive evaluation of nitrite content in Saudi Arabian processed meat and poultry using a novel ultra performance liquid chromatography-mass spectrometry method.

    Science.gov (United States)

    Siddiqui, Masoom Raza; Wabaidur, Saikh Mohammad; Khan, Moonis Ali; ALOthman, Zeid A; Rafiquee, M Z A; Alqadami, Ayoub Abdullah

    2018-01-01

    Quantitative assessment of nitrite (NO 2 - ) anion was performed using a newly developed high throughput ultra performance liquid chromatography-mass spectrometric (UPLC-MS) method. The nitrite determination with the proposed method using micellar mobile phase was unknown. Selected ion reaction mode using negative electrospray ionization was adopted for the identification and quantitative analysis of nitrite. The chromatographic separation was performed using BEH C-18 column and a micellar mobile phase consisted of sodium dodecyl sulphate and acetonitrile in ratio 30:70 was used. The elution of nitrite anion was accomplished in less than 1 min. Under the optimal analysis conditions, the linearity of the developed method was checked in the concentration range of 0.5-20 mg kg -1 NO 2 - with an excellent correlation coefficient of 0.996. The precisions of the method with relative standard deviation <2% was observed when standard at concentration of 1 mg kg -1 was used. The limit of detection and limit of quantitation of the developed mass spectrometric method was found to be 0.114 and 0.346 mg kg -1 , respectively. The developed UPLC/MS method was applied to quantify this anion in processed meats and poultries from various super market of Saudi Arabia (Riyadh region). The recoveries of the nitrite in the various samples were found in the range of 100.03-103.5%.

  18. The importance of mass spectrometric dereplication in fungal secondary metabolite analysis

    DEFF Research Database (Denmark)

    Nielsen, Kristian Fog; Larsen, Thomas Ostenfeld

    2015-01-01

    Having entered the Genomic Era, it is now evident that the biosynthetic potential of filamentous fungi is much larger than was thought even a decade ago. Fungi harbor many cryptic gene clusters encoding for the biosynthesis of polyketides, non-ribosomal peptides, and terpenoids - which can all...... the importance of each stage of the process from sample preparation to chromatographic separation and finally toward both manual and more targeted methods for automated dereplication of fungal natural products using state-of-the art MS instrumentation....

  19. Analyzing chromatographic data using multilevel modeling.

    Science.gov (United States)

    Wiczling, Paweł

    2018-06-01

    It is relatively easy to collect chromatographic measurements for a large number of analytes, especially with gradient chromatographic methods coupled with mass spectrometry detection. Such data often have a hierarchical or clustered structure. For example, analytes with similar hydrophobicity and dissociation constant tend to be more alike in their retention than a randomly chosen set of analytes. Multilevel models recognize the existence of such data structures by assigning a model for each parameter, with its parameters also estimated from data. In this work, a multilevel model is proposed to describe retention time data obtained from a series of wide linear organic modifier gradients of different gradient duration and different mobile phase pH for a large set of acids and bases. The multilevel model consists of (1) the same deterministic equation describing the relationship between retention time and analyte-specific and instrument-specific parameters, (2) covariance relationships relating various physicochemical properties of the analyte to chromatographically specific parameters through quantitative structure-retention relationship based equations, and (3) stochastic components of intra-analyte and interanalyte variability. The model was implemented in Stan, which provides full Bayesian inference for continuous-variable models through Markov chain Monte Carlo methods. Graphical abstract Relationships between log k and MeOH content for acidic, basic, and neutral compounds with different log P. CI credible interval, PSA polar surface area.

  20. Quantitative Analysis of Humectants in Tobacco Products Using Gas Chromatography (GC with Simultaneous Mass Spectrometry (MSD and Flame Ionization Detection (FID

    Directory of Open Access Journals (Sweden)

    Rainey CL

    2014-12-01

    Full Text Available This paper describes the modification of an existing gas chromatographic (GC method to incorporate simultaneous mass spectrometric (MSD and flame ionization detection (FID into the analysis of tobacco humectants. Glycerol, propylene glycol, and triethylene glycol were analyzed in tobacco labeled as roll-your-own (RYO, cigar, cigarette, moist snuff, and hookah tobacco. Tobacco was extracted in methanol containing 1,3-butanediol (internal standard, filtered, and separated on a 15 m megabore DB-Wax column. Post-column flow was distributed using a microfluidic splitter between the MSD and FID for simultaneous detection. The limits of detection for the FID detector were 0.5 μg/mL (propylene glycol and triethylene glycol and 0.25 μg/mL (glycerol with a linear range of 2-2000 μg/mL (propylene glycol and triethylene glycol and 1-4000 μg/mL (glycerol. The limits of detection for the MSD detector were 2 μg/mL (propylene glycol and triethylene glycol and 4 μg/mL (glycerol with a linear range of 20-2000 μg/mL (propylene glycol and triethylene glycol and 40-4000 μg/mL (glycerol. Significant improvement in the sensitivity of the MSD can be achieved by employing selective ion monitoring (SIM detection mode. Although a high degree of correlation was observed between the results from FID and MSD analyses, marginal chromatographic resolution between glycerol and triethylene glycol limits the applicability of FID to samples containing low levels of both of these humectants. Utilizing MSD greatly improves the reliability of quantitative results because compensation for inadequate chromatographic resolution can be accomplished with mass selectivity in detection.

  1. Mass Spectrometric Methodologies for Investigating the Metabolic Signatures of Parkinson's Disease: Current Progress and Future Perspectives.

    Science.gov (United States)

    Gill, Emily L; Koelmel, Jeremy P; Yost, Richard A; Okun, Michael S; Vedam-Mai, Vinata; Garrett, Timothy J

    2018-03-06

    Parkinson's disease (PD) is a neurodegenerative disorder resulting from the loss of dopaminergic neurons of the substantia nigra as well as degeneration of motor and nonmotor basal ganglia circuitries. Typically known for classical motor deficits (tremor, rigidity, bradykinesia), early stages of the disease are associated with a large nonmotor component (depression, anxiety, apathy, etc.). Currently, there are no definitive biomarkers of PD, and the measurement of dopamine metabolites does not allow for detection of prodromal PD nor does it aid in long-term monitoring of disease progression. Given that PD is increasingly recognized as complex and heterogeneous, involving several neurotransmitters and proteins, it is of importance that we advance interdisciplinary studies to further our knowledge of the molecular and cellular pathways that are affected in PD. This approach will possibly yield useful biomarkers for early diagnosis and may assist in the development of disease-modifying therapies. Here, we discuss preanalytical factors associated with metabolomics studies, summarize current mass spectrometric methodologies used to evaluate the metabolic signature of PD, and provide future perspectives of the rapidly developing field of MS in the context of PD.

  2. Optimization of Reversed-Phase Peptide Liquid Chromatography Ultraviolet Mass Spectrometry Analyses Using an Automated Blending Methodology

    Science.gov (United States)

    Chakraborty, Asish B.; Berger, Scott J.

    2005-01-01

    The balance between chromatographic performance and mass spectrometric response has been evaluated using an automated series of experiments where separations are produced by the real-time automated blending of water with organic and acidic modifiers. In this work, the concentration effects of two acidic modifiers (formic acid and trifluoroacetic acid) were studied on the separation selectivity, ultraviolet, and mass spectrometry detector response, using a complex peptide mixture. Peptide retention selectivity differences were apparent between the two modifiers, and under the conditions studied, trifluoroacetic acid produced slightly narrower (more concentrated) peaks, but significantly higher electrospray mass spectrometry suppression. Trifluoroacetic acid suppression of electrospray signal and influence on peptide retention and selectivity was dominant when mixtures of the two modifiers were analyzed. Our experimental results indicate that in analyses where the analyzed components are roughly equimolar (e.g., a peptide map of a recombinant protein), the selectivity of peptide separations can be optimized by choice and concentration of acidic modifier, without compromising the ability to obtain effective sequence coverage of a protein. In some cases, these selectivity differences were explored further, and a rational basis for differentiating acidic modifier effects from the underlying peptide sequences is described. PMID:16522853

  3. Different reactivities of amphetamines with N-methyl-bis(trifluoroacetamide) in heated gas chromatographic injectors.

    Science.gov (United States)

    Hidvégi, E; Hideg, Zs; Somogyi, G P

    2008-03-01

    A fast gas chromatographic mass spectrometric method has been developed earlier for the determination of amphetamine derivatives in human serum and urine. For derivatization, N-methyl-bis(trifluoroacetamide) (MBTFA) was used. Derivatization was performed using an on-line mode, since 1 microl of MBTFA and 1 microl sample extract, dissolved in toluene were injected simultaneously. In this study, the reactivity of the several amphetamine type analytes with MBTFA was investigated. MBTFA used for flash derivatization was applied undiluted on the one hand and diluted 4--4096-fold with acetonitrile on the other hand. Studying several amphetamines in the test sample spiked at the same concentrations we found that they could be divided into 3 groups based on relative target ion peak areas as a function of MBTFA dilution. Group 1, containing only primary amines showed an early increase of the relative peak areas if we increased MBTFA concentration, where group 2 (mainly N-methyl secondary amines) showed that relative peak areas started to increase intensively at higher MBTFA concentrations. Finally, MDEA as an N-ethyl secondary amine, representing group 3, showed significant increase if only slightly diluted MBTFA was used as a flash reagent. This phenomenon can be explained mainly with the less and less reactivity of amine groups in the case of groups 2 and 3, compared to group 1. These findings could help to optimise analytical methods involving flash derivatization processes.

  4. Continuous flow hydride generation-atomic fluorescence spectrometric determination and speciation of arsenic in wine

    Energy Technology Data Exchange (ETDEWEB)

    Karadjova, Irina B. [Faculty of Chemistry, University of Sofia, 1 James Bourchier Blvd., Sofia 1164 (Bulgaria); Lampugnani, Leonardo [C.N.R. Istituto per i processi chimico-fisici, Area della Ricerca di Pisa, Via Moruzzi 1, 56124 Pisa (Italy)]. E-mail: lampugnani@ipcf.cnr.it; Onor, Massimo [C.N.R. Istituto per i processi chimico-fisici, Area della Ricerca di Pisa, Via Moruzzi 1, 56124 Pisa (Italy); D' Ulivo, Alessandro [C.N.R. Istituto per i processi chimico-fisici, Area della Ricerca di Pisa, Via Moruzzi 1, 56124 Pisa (Italy); Tsalev, Dimiter L. [Faculty of Chemistry, University of Sofia, 1 James Bourchier Blvd., Sofia 1164 (Bulgaria)

    2005-07-15

    Methods for the atomic fluorescence spectrometric (AFS) determination of total arsenic and arsenic species in wines based on continuous flow hydride generation (HG) with atomization in miniature diffusion flame (MDF) are described. For hydride-forming arsenic, L-cysteine is used as reagent for pre-reduction and complexation of arsenite, arsenate, monomethylarsonate and dimethylarsinate. Concentrations of hydrochloric acid and tetrahydroborate are optimized in order to minimize interference by ethanol. Procedure permits determination of the sum of these four species in 5-10-fold diluted samples with limit of detection (LOD) 0.3 and 0.6 {mu}g l{sup -1} As in white and red wines, respectively, with precision between 2% and 8% RSD at As levels within 0.5-10 {mu}g l{sup -1}. Selective arsine generation from different reaction media is used for non-chromatographic determination of arsenic species in wines: citrate buffer at pH 5.1 for As(III); 0.2 mol l{sup -1} acetic acid for arsenite + dimethylarsinate (DMA); 8 mol l{sup -1} HCl for total inorganic arsenic [As(III) + As(V)]; and monomethylarsonate (MMA) calculated by difference. Calibration with aqueous and ethanol-matched standard solutions of As(III) is used for 10- and 5-fold diluted samples, respectively. The LODs are 0.4 {mu}g l{sup -1} for As(III) and 0.3 {mu}g l{sup -1} for the other three As species and precision is within 4-8% RSDs. Arsenic species in wine were also determined by coupling of ion chromatographic separation on an anion exchange column and HG-flame AFS detection. Methods were validated by means of recovery studies and comparative analyses by HG-AFS and electrothermal atomic absorption spectrometry after microwave digestion. The LODs were 0.12, 0.27, 0.15 and 0.13 {mu}g l{sup -1} (as As) and RSDs were 2-6%, 5-9%, 3-7% and 2-5% for As(III), As(V), MMA and DMA arsenic species, respectively. Bottled red and white wines from Bulgaria, Republic of Macedonia and Italy were analyzed by non-chromatographic

  5. Continuous flow hydride generation-atomic fluorescence spectrometric determination and speciation of arsenic in wine

    International Nuclear Information System (INIS)

    Karadjova, Irina B.; Lampugnani, Leonardo; Onor, Massimo; D'Ulivo, Alessandro; Tsalev, Dimiter L.

    2005-01-01

    Methods for the atomic fluorescence spectrometric (AFS) determination of total arsenic and arsenic species in wines based on continuous flow hydride generation (HG) with atomization in miniature diffusion flame (MDF) are described. For hydride-forming arsenic, L-cysteine is used as reagent for pre-reduction and complexation of arsenite, arsenate, monomethylarsonate and dimethylarsinate. Concentrations of hydrochloric acid and tetrahydroborate are optimized in order to minimize interference by ethanol. Procedure permits determination of the sum of these four species in 5-10-fold diluted samples with limit of detection (LOD) 0.3 and 0.6 μg l -1 As in white and red wines, respectively, with precision between 2% and 8% RSD at As levels within 0.5-10 μg l -1 . Selective arsine generation from different reaction media is used for non-chromatographic determination of arsenic species in wines: citrate buffer at pH 5.1 for As(III); 0.2 mol l -1 acetic acid for arsenite + dimethylarsinate (DMA); 8 mol l -1 HCl for total inorganic arsenic [As(III) + As(V)]; and monomethylarsonate (MMA) calculated by difference. Calibration with aqueous and ethanol-matched standard solutions of As(III) is used for 10- and 5-fold diluted samples, respectively. The LODs are 0.4 μg l -1 for As(III) and 0.3 μg l -1 for the other three As species and precision is within 4-8% RSDs. Arsenic species in wine were also determined by coupling of ion chromatographic separation on an anion exchange column and HG-flame AFS detection. Methods were validated by means of recovery studies and comparative analyses by HG-AFS and electrothermal atomic absorption spectrometry after microwave digestion. The LODs were 0.12, 0.27, 0.15 and 0.13 μg l -1 (as As) and RSDs were 2-6%, 5-9%, 3-7% and 2-5% for As(III), As(V), MMA and DMA arsenic species, respectively. Bottled red and white wines from Bulgaria, Republic of Macedonia and Italy were analyzed by non-chromatographic and chromatographic procedures and the As

  6. A Simple and Effective Mass Spectrometric Approach to Identify the Adulteration of the Mediterranean Diet Component Extra-Virgin Olive Oil with Corn Oil.

    Science.gov (United States)

    Di Girolamo, Francesco; Masotti, Andrea; Lante, Isabella; Scapaticci, Margherita; Calvano, Cosima Damiana; Zambonin, Carlo; Muraca, Maurizio; Putignani, Lorenza

    2015-09-01

    Extra virgin olive oil (EVOO) with its nutraceutical characteristics substantially contributes as a major nutrient to the health benefit of the Mediterranean diet. Unfortunately, the adulteration of EVOO with less expensive oils (e.g., peanut and corn oils), has become one of the biggest source of agricultural fraud in the European Union, with important health implications for consumers, mainly due to the introduction of seed oil-derived allergens causing, especially in children, severe food allergy phenomena. In this regard, revealing adulterations of EVOO is of fundamental importance for health care and prevention reasons, especially in children. To this aim, effective analytical methods to assess EVOO purity are necessary. Here, we propose a simple, rapid, robust and very sensitive method for non-specialized mass spectrometric laboratory, based on the matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS) coupled to unsupervised hierarchical clustering (UHC), principal component (PCA) and Pearson's correlation analyses, to reveal corn oil (CO) adulterations in EVOO at very low levels (down to 0.5%).

  7. Mass spectrometric analysis of lithium

    International Nuclear Information System (INIS)

    Chitambar, S.A.; Kavimandan, V.D.; Aggarwal, S.K.; Ramasubramanian, P.A.; Shah, P.M.; Almoula, A.I.; Acharya, S.N.; Parab, A.R.; Jain, H.C.; Mathews, C.K.; Ramaniah, M.V.

    1978-01-01

    The details of investigations carried out on the isotopic analysis of lithium using surface ionisation mass spectrometry are presented. Various parameters affecting the precision in isotopic analysis of lithium are discussed. A precision of 1% is achieved in the relative isotope abundance measurement. (author)

  8. Mobile spectrometric laboratory

    International Nuclear Information System (INIS)

    Isajenko, K.A.; Lipinski, P.

    2002-01-01

    The article presents the Mobile Spectrometric Laboratory used by Central Laboratory for Radiological Protection since year 2000. The equipment installed in the Mobile Laboratory and its uses is described. The results of international exercises and intercalibrations, in which the Laboratory participated are presented. (author)

  9. Fast and simple online sample preparation coupled with capillary LC-MS/MS for determination of prostaglandins in cell culture supernatants

    DEFF Research Database (Denmark)

    Rinne, Sandra; Ramstad Kleiveland, Charlotte; Kassem, Moustapha

    2007-01-01

    An online 2-D strong cation exchange (SCX)-RP capillary liquid chromatographic (cLC) method with IT mass spectrometric (IT-MS/MS) detection for the simultaneous determination of prostaglandin (PG) A(1), PGD(2), PGE(1), PGE(2), PGF(2a), 6-keto-(6k)PGF(1a), and 15-Delta(12,14)-deoxy-PGJ(2) (15dPGJ(2...

  10. Determination of rare earth elements in high purity rare earth oxides by liquid chromatography, thermionic mass spectrometry and combined liquid chromatography/thermionic mass spectrometry

    International Nuclear Information System (INIS)

    Stijfhoorn, D.E.; Stray, H.; Hjelmseth, H.

    1993-01-01

    A high-performance liquid chromatographic (HPLC) method for the determination of rare earth elements in rocks has been modified and used for the determination of rare earth elements (REE) in high purity rare earth oxides. The detection limit was 1-1.5 ng or 2-3 mg/kg when a solution corresponding to 0.5 mg of the rare earth oxide was injected. The REE determination was also carried out by adding a mixture of selected REE isotopes to the sample and analysing the collected HPLC-fractions by mass spectrometry (MS) using a thermionic source. Since the matrix element was not collected, interference from this element during the mass spectrometric analysis was avoided. Detection limits as low as 0.5 mg/kg could then be obtained. Detection limits as low as 0.05 mg/kg were possible by MS without HPLC-pre-separation, but this approach could only be used for those elements that were not affected by the matrix. Commercial samples of high purity Nd 2 O 3 , Gd 2 O 3 and Dy 2 O 3 were analysed in this study, and a comparison of results obtained by HPLC, combined HPLC/MS and direct MS is presented. (Author)

  11. Mass spectrometric analysis for nuclear safeguards

    OpenAIRE

    BOULYGA S.; KONEGGER-KAPPEL S.; RICHTER Stephan; SANGELY L.

    2014-01-01

    Mass spectrometry is currently being implemented in a wide spectrum of research and industrial areas, such as material sciences, cosmo- and geochemistry, biology and medicine, to name just a few. Research and development in nuclear safeguards is closely related to the general field of “Peace Research”; representing a specific application area for analytical sciences in general and for mass spectrometry in particular. According to Albert Einstein “peace cannot be kept by force. It only can be ...

  12. Matrix effect and correction by standard addition in quantitative liquid chromatographic-mass spectrometric analysis of diarrhetic shellfish poisoning toxins.

    Science.gov (United States)

    Ito, Shinya; Tsukada, Katsuo

    2002-01-11

    An evaluation of the feasibility of liquid chromatography-mass spectrometry (LC-MS) with atmospheric pressure ionization was made for quantitation of four diarrhetic shellfish poisoning toxins, okadaic acid, dinophysistoxin-1, pectenotoxin-6 and yessotoxin in scallops. When LC-MS was applied to the analysis of scallop extracts, large signal suppressions were observed due to coeluting substances from the column. To compensate for these matrix signal suppressions, the standard addition method was applied. First, the sample was analyzed and then the sample involving the addition of calibration standards is analyzed. Although this method requires two LC-MS runs per analysis, effective correction of quantitative errors was found.

  13. Quantification of rifampicin in human plasma and cerebrospinal fluid by a highly sensitive and rapid liquid chromatographic-tandem mass spectrometric method.

    Science.gov (United States)

    Srivastava, Abhishek; Waterhouse, David; Ardrey, Alison; Ward, Stephen A

    2012-11-01

    A highly sensitive and rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed to measure the levels of the antitubercular drug rifampicin (RIF) in human plasma and cerebrospinal fluid (CSF). The analyte and internal standard (IS) were isolated from plasma and CSF by a simple organic solvent based precipitation of proteins followed by centrifugation. Detection was carried out by electrospray positive ionization mass spectrometry in the multiple-reaction monitoring (MRM) mode. The assay was linear in the concentration range 25-6400 ng/mL with intra- and inter-day precision of <7% and <8%, respectively. The validated method was applied to the study of RIF pharmacokinetics in human CSF and plasma over 25 h period after a 10 mg/kg oral dose. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Development of a mass spectrometrical isotope dilution analysis for determination of trace iodine levels and its application for food samples

    International Nuclear Information System (INIS)

    Schindlmeier, W.

    1984-01-01

    A mass spectrometrical isotope dilution procedure for the determination of trace amounts of iodine in various materials was developed using 129 I as indicator isotope, based on the determination of the 129 I/ 127 I isotope relationship. Negative thermionization was used as ionization method. The analysis procedure, which worked with a standard deviation of between 0,1 and 10% (depending on material tested), was used to determine the iodine level of table salt - both iodized and normal salt (3-6 ppm and less than 0,006 ppm respectively), and food samples with an organic matrix. For comparison the iodine levels were also measured with an iodine-selective electrode. Special preparation and separation procedures were done to suit the sample material. A comparison of the levels of iodine concentration in various powdered milks which were measured by international collaborators using varying methods shows the superior reproducibility of the MS-IDA. (RB) [de

  15. ChromAlign: A two-step algorithmic procedure for time alignment of three-dimensional LC-MS chromatographic surfaces.

    Science.gov (United States)

    Sadygov, Rovshan G; Maroto, Fernando Martin; Hühmer, Andreas F R

    2006-12-15

    We present an algorithmic approach to align three-dimensional chromatographic surfaces of LC-MS data of complex mixture samples. The approach consists of two steps. In the first step, we prealign chromatographic profiles: two-dimensional projections of chromatographic surfaces. This is accomplished by correlation analysis using fast Fourier transforms. In this step, a temporal offset that maximizes the overlap and dot product between two chromatographic profiles is determined. In the second step, the algorithm generates correlation matrix elements between full mass scans of the reference and sample chromatographic surfaces. The temporal offset from the first step indicates a range of the mass scans that are possibly correlated, then the correlation matrix is calculated only for these mass scans. The correlation matrix carries information on highly correlated scans, but it does not itself determine the scan or time alignment. Alignment is determined as a path in the correlation matrix that maximizes the sum of the correlation matrix elements. The computational complexity of the optimal path generation problem is reduced by the use of dynamic programming. The program produces time-aligned surfaces. The use of the temporal offset from the first step in the second step reduces the computation time for generating the correlation matrix and speeds up the process. The algorithm has been implemented in a program, ChromAlign, developed in C++ language for the .NET2 environment in WINDOWS XP. In this work, we demonstrate the applications of ChromAlign to alignment of LC-MS surfaces of several datasets: a mixture of known proteins, samples from digests of surface proteins of T-cells, and samples prepared from digests of cerebrospinal fluid. ChromAlign accurately aligns the LC-MS surfaces we studied. In these examples, we discuss various aspects of the alignment by ChromAlign, such as constant time axis shifts and warping of chromatographic surfaces.

  16. Parallel workflow for high-throughput (>1,000 samples/day quantitative analysis of human insulin-like growth factor 1 using mass spectrometric immunoassay.

    Directory of Open Access Journals (Sweden)

    Paul E Oran

    Full Text Available Insulin-like growth factor 1 (IGF1 is an important biomarker for the management of growth hormone disorders. Recently there has been rising interest in deploying mass spectrometric (MS methods of detection for measuring IGF1. However, widespread clinical adoption of any MS-based IGF1 assay will require increased throughput and speed to justify the costs of analyses, and robust industrial platforms that are reproducible across laboratories. Presented here is an MS-based quantitative IGF1 assay with performance rating of >1,000 samples/day, and a capability of quantifying IGF1 point mutations and posttranslational modifications. The throughput of the IGF1 mass spectrometric immunoassay (MSIA benefited from a simplified sample preparation step, IGF1 immunocapture in a tip format, and high-throughput MALDI-TOF MS analysis. The Limit of Detection and Limit of Quantification of the resulting assay were 1.5 μg/L and 5 μg/L, respectively, with intra- and inter-assay precision CVs of less than 10%, and good linearity and recovery characteristics. The IGF1 MSIA was benchmarked against commercially available IGF1 ELISA via Bland-Altman method comparison test, resulting in a slight positive bias of 16%. The IGF1 MSIA was employed in an optimized parallel workflow utilizing two pipetting robots and MALDI-TOF-MS instruments synced into one-hour phases of sample preparation, extraction and MSIA pipette tip elution, MS data collection, and data processing. Using this workflow, high-throughput IGF1 quantification of 1,054 human samples was achieved in approximately 9 hours. This rate of assaying is a significant improvement over existing MS-based IGF1 assays, and is on par with that of the enzyme-based immunoassays. Furthermore, a mutation was detected in ∼1% of the samples (SNP: rs17884626, creating an A→T substitution at position 67 of the IGF1, demonstrating the capability of IGF1 MSIA to detect point mutations and posttranslational modifications.

  17. Standard test methods for chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade uranium dioxide powders and pellets

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 These test methods cover procedures for the chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade uranium dioxide powders and pellets to determine compliance with specifications. 1.2 This test method covers the determination of uranium and the oxygen to uranium atomic ratio in nuclear-grade uranium dioxide powder and pellets. 1.4 This test method covers the determination of chlorine and fluorine in nuclear-grade uranium dioxide. With a 1 to 10-g sample, concentrations of 5 to 200 g/g of chlorine and 1 to 200 μg/g of fluorine are determined without interference. 1.5 This test method covers the determination of moisture in uranium dioxide samples. Detection limits are as low as 10 μg. 1.6 This test method covers the determination of nitride nitrogen in uranium dioxide in the range from 10 to 250 μg. 1.7 This test method covers the spectrographic analysis of nuclear-grade UO2 for the 26 elements in the ranges indicated in Table 2. 1.8 For simultaneous determination of trace ele...

  18. Vaporization study on vanadium monoxide and two-phase mixture of vanadium and vanadium monoxide by mass-spectrometric method

    International Nuclear Information System (INIS)

    Banchorndhevakul, W.; Matsui, Tsuneo; Naito, Keiji

    1986-01-01

    The vapor pressures over single phase vanadium monoxide VO 1.022 (s) and the two-phase mixture of vanadium metal (β phase) and vanadium monoxide were measured by mass-spectrometric method in the temperature range of 1,803 ∼ 1,990 and 1,703 ∼ 1,884 K, respectively. The main gas species over both systems were found to be VO(g) and V(g). The vapor pressure of VO(g) over the two-phase mixture of V(s) and VO(s) was a little lower than that over single phase VO(s). The vapor pressure of V(g) over the two-phase mixture was nearly equal to that over single phase. From the vapor pressure data, the enthalpies of vaporization, the enthalpies of formation for VO(g) and V(g) and the dissociation energy of VO(g) were determined. The oxygen partial pressure was calculated as a function of temperature from the vapor pressures of VO(g) and V(g), from which the partial molar enthalpies and entropies of oxygen in both systems were obtained. (author)

  19. Determination of nifedipine in dog plasma by high-performance liquid chromatography with tandem mass spectrometric detection.

    Science.gov (United States)

    Pan, Xigui; Zhou, Shunchang; Fu, Qinqin; Hu, Xianming; Wu, Jianhong

    2014-07-01

    Nifedipine is a dihydropyridine calcium channel blocker used widely in the management of hypertension and other cardiovascular disorders. In this work, a simple, rapid and sensitive liquid chromatography/tandem mass spectrometry method was developed and validated to determine nifedipine in dog plasma using nimodipine as the internal standard. Chromatographic separation was carried out on a C₈ column. The mobile phase consisted of a mixture of acetonitrile, water and formic acid (60:40:0.2, v/v/v) at a flow rate of 0.5 mL/min. Detection was performed on a triple quadrupole tandem mass spectrometer in selected reaction monitoring mode via an atmospheric pressure chemical ionization source. The method has a lower limit of quantification of 0.20 ng/mL with consumption of plasma as low as 0.05 mL. The linear calibration curves were obtained in the concentration range of 0.20-50.0 ng/mL (r = 0.9948). The recoveries of the liquid extraction method were 74.5-84.1%. Intra-day and inter-day precisions were 4.1-8.8 and 6.7-7.4%, respectively. The quantification was not interfered with by other plasma components and the method was applied to determine nifedipine in plasma after a single oral administration of two controlled-release nifedipine tablets to beagle dogs. Copyright © 2013 John Wiley & Sons, Ltd.

  20. Mass spectrometric measurement of urinary kynurenine-to-tryptophan ratio in children with and without urinary tract infection.

    Science.gov (United States)

    Yarbrough, Melanie L; Briden, Kelleigh E; Mitsios, John V; Weindel, Annette L; Terrill, Cindy M; Hunstad, David A; Dietzen, Dennis J

    2018-04-19

    Indoleamine-2,3-dioxygenase (IDO) catalyzes the first step of tryptophan (Trp) catabolism, yielding kynurenine (Kyn) metabolites. The kynurenine-to-tryptophan (K/T) ratio is used as a surrogate for biological IDO enzyme activity. IDO expression is increased during Escherichia coli urinary tract infection (UTI). Thus, our objective was to develop a method for measurement of Kyn/Trp ratio in human blood and urine and evaluate its use as a biomarker of UTI. A mass spectrometric method was developed to measure Trp and Kyn in serum and urine specimens. The method was applied to clinical urine specimens from symptomatic pediatric patients with laboratory-confirmed UTI or other acute conditions and from healthy controls. The liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was linear to 500 μmol/L for both Trp and Kyn. Imprecision ranged from 5 to 15% for Trp and 6-20% for Kyn. Analytical recoveries of Trp and Kyn ranged from 96 to 119% in serum and 90-97% in urine. No correlation was found between the K/T ratio and circulating IDO mass (r = 0.110) in serum. Urinary Kyn and Trp in the pediatric test cohort demonstrated elevations in the K/T ratio in symptomatic patients with UTI (median 13.08) and without UTI (median 14.38) compared to healthy controls (median 4.93; p < 0.001 for both comparisons). No significant difference in K/T ratio was noted between symptomatic patients with and without UTI (p = 0.84). Measurement of Trp and Kyn by LC-MS/MS is accurate and precise in serum and urine specimens. While urinary K/T ratio is not a specific biomarker for UTI, it may represent a general indicator of a systemic inflammatory process. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  1. Mass spectrometer introduction line: application to the analysis of impurities in uranium hexafluoride; Ligne d'introduction pour spectrometre de masse: application a l'analyse des impuretes contenues dans l'UF{sub 6}

    Energy Technology Data Exchange (ETDEWEB)

    Besson, M. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires. Departement de physico-chimie, service des isotopes stables, section de spectrometrie de masse

    1967-01-01

    The continuous mass-spectrometric analysis of impurities in UF{sub 6} is possible industrially if certain conditions imposed by the nature of the gas are respected. The gas introduction line arriving at the spectrometer's source makes it possible to fix the flow-rate, to control the inlet pressure and to selectively destroy the gas containing the impurities. The operational conditions for the line are defined and a description is given of the theoretical and experimental study of the various elements of which it is composed, i.e. the leak valve, the flow-meter, the chemical trap and the servo-mechanism making it possible to regulate and control the gas flow. The dynamic characteristics of the line's various components and the performance of the equipment in the case of the analyses considered are given. (author) [French] L'analyse en continu par spectrometrie de masse des impuretes contenus dans l'UF{sub 6} est possible industriellement moyennant certaines conditions imposees par la nature du gaz. La ligne d'introduction des gaz dans la source du spectrometre permet de regler le debit, de controler la pression d'introduction et de detruire selectivement le gaz porteur d'impuretes. Les conditions de fonctionnement de la ligne etant definies, on decrit l'etude theorique et experimentale des differents elements qui la composent, c'est-a-dire: le robinet a fuite, le debitmetre, le piege chimique et l'ensemble d'asservissement permettant la regulation et le controle du debit. On donne les caracteristiques dynamiques des differents constituants de la ligne et les performances de l'ensemble pour les analyses considerees. (auteur)

  2. Ethanol analysis by headspace gas chromatography with simultaneous flame-ionization and mass spectrometry detection.

    Science.gov (United States)

    Tiscione, Nicholas B; Alford, Ilene; Yeatman, Dustin Tate; Shan, Xiaoqin

    2011-09-01

    Ethanol is the most frequently identified compound in forensic toxicology. Although confirmation involving mass spectrometry is desirable, relatively few methods have been published to date. A novel technique utilizing a Dean's Switch to simultaneously quantitate and confirm ethyl alcohol by flame-ionization (FID) and mass spectrometric (MS) detection after headspace sampling and gas chromatographic separation is presented. Using 100 μL of sample, the limits of detection and quantitation were 0.005 and 0.010 g/dL, respectively. The zero-order linear range (r(2) > 0.990) was determined to span the concentrations of 0.010 to 1.000 g/dL. The coefficient of variation of replicate analyses was less than 3.1%. Quantitative accuracy was within ±8%, ±6%, ±3%, and ±1.5% at concentrations of 0.010, 0.025, 0.080, and 0.300 g/dL, respectively. In addition, 1,1-difluoroethane was validated for qualitative identification by this method. The validated FID-MS method provides a procedure for the quantitation of ethyl alcohol in blood by FID with simultaneous confirmation by MS and can also be utilized as an identification method for inhalants such as 1,1-difluoroethane.

  3. Evaluation of mass spectrometric data using principal component analysis for determination of the effects of organic lakes on protein binder identification.

    Science.gov (United States)

    Hrdlickova Kuckova, Stepanka; Rambouskova, Gabriela; Hynek, Radovan; Cejnar, Pavel; Oltrogge, Doris; Fuchs, Robert

    2015-11-01

    Matrix-assisted laser desorption/ionisation-time of flight (MALDI-TOF) mass spectrometry is commonly used for the identification of proteinaceous binders and their mixtures in artworks. The determination of protein binders is based on a comparison between the m/z values of tryptic peptides in the unknown sample and a reference one (egg, casein, animal glues etc.), but this method has greater potential to study changes due to ageing and the influence of organic/inorganic components on protein identification. However, it is necessary to then carry out statistical evaluation on the obtained data. Before now, it has been complicated to routinely convert the mass spectrometric data into a statistical programme, to extract and match the appropriate peaks. Only several 'homemade' computer programmes without user-friendly interfaces are available for these purposes. In this paper, we would like to present our completely new, publically available, non-commercial software, ms-alone and multiMS-toolbox, for principal component analyses of MALDI-TOF MS data for R software, and their application to the study of the influence of heterogeneous matrices (organic lakes) for protein identification. Using this new software, we determined the main factors that influence the protein analyses of artificially aged model mixtures of organic lakes and fish glue, prepared according to historical recipes that were used for book illumination, using MALDI-TOF peptide mass mapping. Copyright © 2015 John Wiley & Sons, Ltd.

  4. Determination of trihalomethanes in waters by ionic liquid-based single drop microextraction/gas chromatographic/mass spectrometry.

    Science.gov (United States)

    Aguilera-Herrador, Eva; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel

    2008-10-31

    A simple, rapid, solventless method for the determination of trihalomethanes (THMs) (chloroform, bromodichloromethane, dibromochloromethane and bromoform) in water samples is presented. The analytes are extracted from the headspace of the aqueous matrix into a 2 microL drop of the ionic liquid 1-octyl-3-methyl-imidazolium hexafluorophosphate working at 30 degrees C for 30 min. The separation and detection of the target compounds is accomplished by gas chromatography/mass spectrometry owing to the use of an interface that efficiently transfers the analytes extracted in the ionic liquid drop to the gas chromatograph while preventing the ionic liquid from entering the column. The detection limits obtained are below the values compelled by the legislation, ranging from 0.5 microg L(-1) for chloroform and bromodichloromethane to 0.9 microg L(-1) for dibromochloromethane. The use of ionic liquid in the extraction procedure avoids the use of organic solvents and leads to relative standard deviations that range from 3.1% to 4.8%.

  5. Glycomics using mass spectrometry

    OpenAIRE

    Wuhrer, Manfred

    2013-01-01

    Mass spectrometry plays an increasingly important role in structural glycomics. This review provides an overview on currently used mass spectrometric approaches such as the characterization of glycans, the analysis of glycopeptides obtained by proteolytic cleavage of proteins and the analysis of glycosphingolipids. The given examples are demonstrating the application of mass spectrometry to study glycosylation changes associated with congenital disorders of glycosylation, lysosomal storage di...

  6. Extensive characterization of Tupaia belangeri neuropeptidome using an integrated mass spectrometric approach.

    Science.gov (United States)

    Petruzziello, Filomena; Fouillen, Laetitia; Wadensten, Henrik; Kretz, Robert; Andren, Per E; Rainer, Gregor; Zhang, Xiaozhe

    2012-02-03

    Neuropeptidomics is used to characterize endogenous peptides in the brain of tree shrews (Tupaia belangeri). Tree shrews are small animals similar to rodents in size but close relatives of primates, and are excellent models for brain research. Currently, tree shrews have no complete proteome information available on which direct database search can be allowed for neuropeptide identification. To increase the capability in the identification of neuropeptides in tree shrews, we developed an integrated mass spectrometry (MS)-based approach that combines methods including data-dependent, directed, and targeted liquid chromatography (LC)-Fourier transform (FT)-tandem MS (MS/MS) analysis, database construction, de novo sequencing, precursor protein search, and homology analysis. Using this integrated approach, we identified 107 endogenous peptides that have sequences identical or similar to those from other mammalian species. High accuracy MS and tandem MS information, with BLAST analysis and chromatographic characteristics were used to confirm the sequences of all the identified peptides. Interestingly, further sequence homology analysis demonstrated that tree shrew peptides have a significantly higher degree of homology to equivalent sequences in humans than those in mice or rats, consistent with the close phylogenetic relationship between tree shrews and primates. Our results provide the first extensive characterization of the peptidome in tree shrews, which now permits characterization of their function in nervous and endocrine system. As the approach developed fully used the conservative properties of neuropeptides in evolution and the advantage of high accuracy MS, it can be portable for identification of neuropeptides in other species for which the fully sequenced genomes or proteomes are not available.

  7. Quantitative determination of plant phenolics in Urtica dioica extracts by high-performance liquid chromatography coupled with tandem mass spectrometric detection.

    Science.gov (United States)

    Orčić, Dejan; Francišković, Marina; Bekvalac, Kristina; Svirčev, Emilija; Beara, Ivana; Lesjak, Marija; Mimica-Dukić, Neda

    2014-01-15

    A method for quantification of 45 plant phenolics (including benzoic acids, cinnamic acids, flavonoid aglycones, C- and O-glycosides, coumarins, and lignans) in plant extracts was developed, based on reversed phase HPLC separation of extract components, followed by tandem mass spectrometric detection. The phenolic profile of 80% MeOH extracts of the stinging nettle (Urtica dioica L.) herb, root, stem, leaf and inflorescence was obtained by using this method. Twenty-one of the investigated compounds were present at levels above the reliable quantification limit, with 5-O-caffeoylquinic acid, rutin and isoquercitrin as the most abundant. The inflorescence extracts were by far the richest in phenolics, with the investigated compounds amounting 2.5-5.1% by weight. As opposed to this, the root extracts were poor in phenolics, with only several acids and derivatives being present in significant amounts. The results obtained by the developed method represent the most detailed U. dioica chemical profile so far. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Ground-based intercomparison of two isoprene measurement techniques

    Directory of Open Access Journals (Sweden)

    E. Leibrock

    2003-01-01

    Full Text Available An informal intercomparison of two isoprene (C5H8 measurement techniques was carried out during Fall of 1998 at a field site located approximately 3 km west of Boulder, Colorado, USA. A new chemical ionization mass spectrometric technique (CIMS was compared to a well-established gas chromatographic technique (GC. The CIMS technique utilized benzene cation chemistry to ionize isoprene. The isoprene levels measured by the CIMS were often larger than those obtained with the GC. The results indicate that the CIMS technique suffered from an anthropogenic interference associated with air masses from the Denver, CO metropolitan area as well as an additional interference occurring in clean conditions. However, the CIMS technique is also demonstrated to be sensitive and fast. Especially after introduction of a tandem mass spectrometric technique, it is therefore a candidate for isoprene measurements in remote environments near isoprene sources.

  9. A sensitive mass spectrometric method for hypothesis-driven detection of peptide post-translational modifications: multiple reaction monitoring-initiated detection and sequencing (MIDAS).

    Science.gov (United States)

    Unwin, Richard D; Griffiths, John R; Whetton, Anthony D

    2009-01-01

    The application of a targeted mass spectrometric workflow to the sensitive identification of post-translational modifications is described. This protocol employs multiple reaction monitoring (MRM) to search for all putative peptides specifically modified in a target protein. Positive MRMs trigger an MS/MS experiment to confirm the nature and site of the modification. This approach, termed MIDAS (MRM-initiated detection and sequencing), is more sensitive than approaches using neutral loss scanning or precursor ion scanning methodologies, due to a more efficient use of duty cycle along with a decreased background signal associated with MRM. We describe the use of MIDAS for the identification of phosphorylation, with a typical experiment taking just a couple of hours from obtaining a peptide sample. With minor modifications, the MIDAS method can be applied to other protein modifications or unmodified peptides can be used as a MIDAS target.

  10. The use of mass spectrometry to analyze dried blood spots.

    Science.gov (United States)

    Wagner, Michel; Tonoli, David; Varesio, Emmanuel; Hopfgartner, Gérard

    2016-01-01

    Dried blood spots (DBS) typically consist in the deposition of small volumes of capillary blood onto dedicated paper cards. Comparatively to whole blood or plasma samples, their benefits rely in the fact that sample collection is easier and that logistic aspects related to sample storage and shipment can be relatively limited, respectively, without the need of a refrigerator or dry ice. Originally, this approach has been developed in the sixties to support the analysis of phenylalanine for the detection of phenylketonuria in newborns using bacterial inhibition test. In the nineties tandem mass spectrometry was established as the detection technique for phenylalanine and tyrosine. DBS became rapidly recognized for their clinical value: they were widely implemented in pediatric settings with mass spectrometric detection, and were closely associated to the debut of newborn screening (NBS) programs, as a part of public health policies. Since then, sample collection on paper cards has been explored with various analytical techniques in other areas more or less successfully regarding large-scale applications. Moreover, in the last 5 years a regain of interest for DBS was observed and originated from the bioanalytical community to support drug development (e.g., PK studies) or therapeutic drug monitoring mainly. Those recent applications were essentially driven by improved sensitivity of triple quadrupole mass spectrometers. This review presents an overall view of all instrumental and methodological developments for DBS analysis with mass spectrometric detection, with and without separation techniques. A general introduction to DBS will describe their advantages and historical aspects of their emergence. A second section will focus on blood collection, with a strong emphasis on specific parameters that can impact quantitative analysis, including chromatographic effects, hematocrit effects, blood effects, and analyte stability. A third part of the review is dedicated to

  11. Characterization and analysis of structural isomers of dimethyl methoxypyrazines in cork stoppers and ladybugs (Harmonia axyridis and Coccinella septempunctata).

    Science.gov (United States)

    Slabizki, Petra; Legrum, Charlotte; Meusinger, Reinhard; Schmarr, Hans-Georg

    2014-10-01

    The three constitutional isomers of dimethyl-substituted methoxypyrazines: 3,5-dimethyl-2-methoxypyrazine 1; 2,5-dimethyl-3-methoxypyrazine 2; and 2,3-dimethyl-5-methoxypyrazine 3 are potent flavor compounds with similar mass spectrometric, gas chromatographic, and nuclear magnetic resonance spectroscopic behavior. Therefore, unambiguous analytical determination is critical, particularly in complex matrices. The unequivocal identification of 1-3 could be achieved by homo- and heteronuclear NMR correlation experiments. The observed mass fragmentation for 1-3 is proposed and discussed, benefitting from synthesized partially deuterated 1 and 2. On common polar and apolar stationary phases used in gas chromatography (GC) 1 and 2 show similar behavior whereas 3 can be separated. In our focus on off-flavor analysis with respect to wine aroma, 1 has been described as a "moldy" off-flavor compound in cork and 2 as a constituent in Harmonia axyridis contributing to the so-called "ladybug taint," whereas 3 has not yet been described as a constituent of wine aroma. A successful separation of 1 and 2 could be achieved on octakis-(2,3-di-O-pentyl-6-O-methyl)-γ-cyclodextrin as stationary phase in GC. Applying heart-cut multidimensional GC analysis with tandem mass spectrometric detection we could confirm the presence of 1 as a "moldy" off-flavor compound in cork. However, in the case of Harmonia axyridis, a previous identification of 2 has to be reconsidered. In our experiments we identified the constitutional isomer 1, which was also found in Coccinella septempunctata, another species discussed with respect to the "ladybug taint." The analysis of such structurally related compounds is a demonstrative example for the importance of a chromatographic separation, as mass spectrometric data by itself could not guarantee the unequivocal identification.

  12. The IDA-80 measurement evaluation programme on mass spectrometric isotope dilution analysis of uranium and plutonium. Vol. 1

    International Nuclear Information System (INIS)

    Beyrich, W.; Golly, W.; Spannagel, G.; Kernforschungszentrum Karlsruhe G.m.b.H.; Bievre, P. de; Wolters, W.

    1984-12-01

    The main objective was the acquisition of basic data on the uncertainties involved in the mass spectrometric isotope dilution analysis as applied to the determination of uranium and plutonium in active feed solutions of reprocessing plants. The element concentrations and isotopic compositions of all test materials used were determined by CBNM and NBS with high accuracy. The more than 60000 analytical data reported by the participating laboratories were evaluated by statistical methods applied mainly to the calculation of estimates of the variances for the different uncertainty components contributing to the total uncertainty of this analytical technique. Attention was given to such topics as sample ageing, influence of fission products, spike calibration, ion fractionation, Pu-241 decay correction, minor isotope measurement and errors in data transfer. Furthermore, the performance of the 'dried sample' technique and the 'in-situ' spiking method of undiluted samples of reprocessing fuel solution with U-235/Pu-242 metal alloy spikes, were tested successfully. Considerable improvement of isotope dilution analysis in this safeguards relevant application during the last decade is shown as compared to the results obtained in the IDA-72 interlaboratory experiment, organized by KfK in 1972 on the same subject. (orig./HP) [de

  13. Hazards control progress report No. 57, October-March 1979

    International Nuclear Information System (INIS)

    Griffith, R.V.

    1979-01-01

    Progress is reported in research on the following subjects: gas chromatographic/mass spectrometric analysis of thermal degradation products from wood and composite burns; corrosion in the experimental ducting of the fire test cell; on-line x-ray fluorescence analysis of transition metals in waste water: Phase II; fire environmental tests for self-contained breathing apparatus; developments in neutron spectrometry; and, intermediate energy x-ray spectra for general shielding calculations

  14. Modeling Aquatic Toxicity through Chromatographic Systems.

    Science.gov (United States)

    Fernández-Pumarega, Alejandro; Amézqueta, Susana; Farré, Sandra; Muñoz-Pascual, Laura; Abraham, Michael H; Fuguet, Elisabet; Rosés, Martí

    2017-08-01

    Environmental risk assessment requires information about the toxicity of the growing number of chemical products coming from different origins that can contaminate water and become toxicants to aquatic species or other living beings via the trophic chain. Direct toxicity measurements using sensitive aquatic species can be carried out but they may become expensive and ethically questionable. Literature refers to the use of chromatographic measurements that correlate to the toxic effect of a compound over a specific aquatic species as an alternative to get toxicity information. In this work, we have studied the similarity in the response of the toxicity to different species and we have selected eight representative aquatic species (including tadpoles, fish, water fleas, protozoan, and bacteria) with known nonspecific toxicity to chemical substances. Next, we have selected four chromatographic systems offering good perspectives for surrogation of the eight selected aquatic systems, and thus prediction of toxicity from the chromatographic measurement. Then toxicity has been correlated to the chromatographic retention factor. Satisfactory correlation results have been obtained to emulate toxicity in five of the selected aquatic species through some of the chromatographic systems. Other aquatic species with similar characteristics to these five representative ones could also be emulated by using the same chromatographic systems. The final aim of this study is to model chemical products toxicity to aquatic species by means of chromatographic systems to reduce in vivo testing.

  15. Fourier Transform Mass Spectrometry: The Transformation of Modern Environmental Analyses

    Science.gov (United States)

    Lim, Lucy; Yan, Fangzhi; Bach, Stephen; Pihakari, Katianna; Klein, David

    2016-01-01

    Unknown compounds in environmental samples are difficult to identify using standard mass spectrometric methods. Fourier transform mass spectrometry (FTMS) has revolutionized how environmental analyses are performed. With its unsurpassed mass accuracy, high resolution and sensitivity, researchers now have a tool for difficult and complex environmental analyses. Two features of FTMS are responsible for changing the face of how complex analyses are accomplished. First is the ability to quickly and with high mass accuracy determine the presence of unknown chemical residues in samples. For years, the field has been limited by mass spectrometric methods that were based on knowing what compounds of interest were. Secondly, by utilizing the high resolution capabilities coupled with the low detection limits of FTMS, analysts also could dilute the sample sufficiently to minimize the ionization changes from varied matrices. PMID:26784175

  16. Mono-, di- and trimethylated homologues of isoprenoid tetraether lipid cores in archaea and environmental samples: mass spectrometric identification and significance.

    Science.gov (United States)

    Knappy, Chris; Barillà, Daniela; Chong, James; Hodgson, Dominic; Morgan, Hugh; Suleman, Muhammad; Tan, Christine; Yao, Peng; Keely, Brendan

    2015-12-01

    Higher homologues of widely reported C(86) isoprenoid diglycerol tetraether lipid cores, containing 0-6 cyclopentyl rings, have been identified in (hyper)thermophilic archaea, representing up to 21% of total tetraether lipids in the cells. Liquid chromatography-tandem mass spectrometry confirms that the additional carbon atoms in the C(87-88) homologues are located in the etherified chains. Structures identified include dialkyl and monoalkyl ('H-shaped') tetraethers containing C(40-42) or C(81-82) hydrocarbons, respectively, many representing novel compounds. Gas chromatography-mass spectrometric analysis of hydrocarbons released from the lipid cores by ether cleavage suggests that the C(40) chains are biphytanes and the C(41) chains 13-methylbiphytanes. Multiple isomers, having different chain combinations, were recognised among the dialkyl lipids. Methylated tetraethers are produced by Methanothermobacter thermautotrophicus in varying proportions depending on growth conditions, suggesting that methylation may be an adaptive mechanism to regulate cellular function. The detection of methylated lipids in Pyrobaculum sp. AQ1.S2 and Sulfolobus acidocaldarius represents the first reported occurrences in Crenarchaeota. Soils and aquatic sediments from geographically distinct mesotemperate environments that were screened for homologues contained monomethylated tetraethers, with di- and trimethylated structures being detected occasionally. The structural diversity and range of occurrences of the C(87-89) tetraethers highlight their potential as complementary biomarkers for archaea in natural environments. Copyright © 2015 John Wiley & Sons, Ltd.

  17. Study PWA8 resin for chromatographic uranium concentration

    International Nuclear Information System (INIS)

    Coceancigh, Herman; Ramella, J. L.; Marrero, Julieta; Jiménez Rebagliati, Raúl

    2013-01-01

    For many years nuclear industry have been using resins as filler of chromatographic columns. These methods are specific and give reliable results in different applications, for those reasons are extremely useful as separation process. Currently the nuclear industry is growing and this brings new issues such as the need of reduction of the amount of waste, the optimization of the production process and others that the chromatography could solve with great results. AMBERLITETM PWA8 resin is an anion exchange resin which can be used for the removal of uranium from drinking water. In addition to high exchange capacity, this resin has excellent physical stability and a wide range of pH in which is operational. With the idea of concentrating uranium from wastes solution as main goal we made different experiments to understand the AMBERLITETM PWA8 and obtain the most important characteristics like; pH working range; capacity; activation and elution procedures. These procedures were developed and optimized the capacity was determined using a batch experiment and we obtain that the maximum capacity is 882,5 U ug /resin gr at a pH of 4,2. Following on from these results chromatographic experiments were performed in which both were obtained the percentage of recovery and the concentration factor. The percent recovery (% R) calculated as the percentage ratio between the total mass and the load mass eluted (% R = eluted mass / total mass * 100) was 94% with a concentration factor of 5 times From these results it is intended to concentrate wastes solutions from the fuel cycle processes with two main goals: decreasing volume for storage and for future reusing of the uranium coming from production. (author)

  18. Improved sample preparation method for environmental plutonium analysis by ICP-SFMS and alpha-spectrometry

    International Nuclear Information System (INIS)

    Varga, Z.; Stefanka, Z.; Suranyi, G.; Vajda, N.

    2007-01-01

    A rapid and simple sample preparation method for plutonium determination in environmental samples by inductively coupled plasma sector field mass spectrometry (ICP-SFMS) and alpha-spectrometry is described. The developed procedure involves a selective CaF 2 co-precipitation for preconcentration followed by extraction chromatographic separation. The proposed method effectively eliminates the possible interferences in mass spectrometric analysis and also removes interfering radionuclides that may disturb alpha-spectrometric measurement. For 239 Pu, 240 Pu and 241 Pu limits of detection of 9.0 fg x g -1 (0.021 mBq), 1.7 fg x g -1 (0.014 mBq) and 3.1 fg x g -1 (11.9 mBq) were achieved by ICP-SFMS, respectively, and 0.02 mBq by alpha-spectrometry. Results of certified reference materials agreed well with the recommended values. (author)

  19. Radioimmunoassay and liquid-chromatographic analysis for free cortisol in urine compared with isotope dilution-mass spectrometry

    International Nuclear Information System (INIS)

    Lantto, O.

    1982-01-01

    Three different routine methods for analysis for urinary cortisol with those by a highly specific reference method based on isotope dilution-mass spectrometry (I) were compared. A ''high-performance'' liquid-chromatographic method (II) gave the most comparable results (regression coefficient 0.86, intercept 9 nmol/L). For some urines much lower values were obtained by I than by II. Two radioimmunoassay (III) methods, one involving direct assay and one involving extraction, gave less-accurate results (regression coefficients of 1.87 and 1.52 and intercepts of 86 and 12 nmol/L, respectively), although values obtained by III and by I correlated well (r = 0.95-0.99), indicating a relation between the free cortisol and the compounds interfering in III. The apparent accuracy for the extraction method was improved by using as calibration standards urine samples previously assayed by I (regression coefficient 0.90, intercept 6 nmol/L). All four methods investigated showed a statistically significant sex-related difference in 24-h urinary cortisol excretion; evidently such a finding should be a prerequisite in any such method proposed for routine use

  20. Graphene oxide membrane as an efficient extraction and ionization substrate for spray-mass spectrometric analysis of malachite green and its metabolite in fish samples.

    Science.gov (United States)

    Wei, Shih-Chun; Fan, Shen; Lien, Chia-Wen; Unnikrishnan, Binesh; Wang, Yi-Sheng; Chu, Han-Wei; Huang, Chih-Ching; Hsu, Pang-Hung; Chang, Huan-Tsung

    2018-03-20

    A graphene oxide (GO) nanosheet-modified N + -nylon membrane (GOM) has been prepared and used as an extraction and spray-ionization substrate for robust mass spectrometric detection of malachite green (MG), a highly toxic disinfectant in liquid samples and fish meat. The GOM is prepared by self-deposition of GO thin film onto an N + -nylon membrane, which has been used for efficient extraction of MG in aquaculture water samples or homogenized fish meat samples. Having a dissociation constant of 2.17 × 10 -9  M -1 , the GOM allows extraction of approximately 98% of 100 nM MG. Coupling of the GOM-spray with an ion-trap mass spectrometer allows quantitation of MG in aquaculture freshwater and seawater samples down to nanomolar levels. Furthermore, the system possesses high selectivity and sensitivity for the quantitation of MG and its metabolite (leucomalachite green) in fish meat samples. With easy extraction and efficient spray ionization properties of GOM, this membrane spray-mass spectrometry technique is relatively simple and fast in comparison to the traditional LC-MS/MS methods for the quantitation of MG and its metabolite in aquaculture products. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Simultaneous determination of tedizolid and linezolid in rat plasma by ultra performance liquid chromatography tandem mass spectrometry and its application to a pharmacokinetic study.

    Science.gov (United States)

    Yu, Hua-chen; Pan, Chen-wei; Xie, Qi-peng; Zheng, Yi; Hu, Yue-zheng; Lin, Yi-mu

    2016-02-01

    A sensitive and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed to determine tedizolid and linezolid in rat plasma simultaneously. Chromatographic separation was carried out on an Acquity UPLC BEH C18 column and mass spectrometric analysis was performed using a XEVO TQD triple quadruple mass spectrometer coupled with an electrospray ionization (ESI) source in the positive ion mode. Multiple reaction monitoring (MRM) mode was used for quantification using target fragment ions m/z 371.4→343.2 for tedizolid, and m/z 338.3→56.1 for linezolid. This assay method has been fully validated in terms of selectivity, linearity, recovery and matrix effect, accuracy, precision and stability. The linearity of this method was found to be within the concentration range of 5-5000ng/mL for tedizolid, and 10-10,000ng/mL for linezolid in rat plasma, respectively. Only 3.0min was needed for an analytical run. This assay was used to support a preclinical study where multiple oral doses were administered to rats to investigate the pharmacokinetics of tedizolid and linezolid. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. HPLC-MS technique for radiopharmaceuticals analysis and quality control

    International Nuclear Information System (INIS)

    Macasek, F.; Buriova, E.; Bruder, P.; Vera-Ruiz, H.

    2003-01-01

    Potentialities of liquid chromatography with mass spectrometric detector (MSD) were investigated with the objective of quality control of radiopharmaceuticals; 2-deoxy-2-[ 18 F]fluoro-D-glucose (FDG) being an example. Screening of suitable MSD analytical lines is presented. Mass-spectrometric monitoring of acetonitrile-aqueous ammonium formate eluant by negatively charged FDG.HCO 2 - ions enables isotope analysis (specific activity) of the radiopharmaceutical at m/z 227 and 226. Kryptofix 222 provides an intense MSD signal of the positive ion associated with NH 4 + at m/z 394. Expired FDG injection samples contain decomposition products from which at least one labelled by 18 F and characterised by signal of negative ions at m/z 207 does not correspond to FDG fragments but to C5 decomposition products. A glucose chromatographic peak, characterised by m/z 225 negative ion is accompanied by a tail of a component giving a signal of m/z 227, which can belong to [ 18 O]glucose; isobaric sorbitol signals were excluded but FDG-glucose association occurs in the co-elution of separation of model mixtures. The latter can actually lead to a convoluted chromatographic peak, but the absence of 18 F makes this inconsistent. Quantification and validation of the FDG component analysis is under way. (author)

  3. Mass Spectrometry Instrumentation in Proteomics

    DEFF Research Database (Denmark)

    Sprenger, Richard Remko; Roepstorff, Peter

    2012-01-01

    Mass spectrometry has evolved into a crucial technology for the field of proteomics, enabling the comprehensive study of proteins in biological systems. Innovative developments have yielded flexible and versatile mass spectrometric tools, including quadrupole time-of-flight, linear ion trap......, Orbitrap and ion mobility instruments. Together they offer various and complementary capabilities in terms of ionization, sensitivity, speed, resolution, mass accuracy, dynamic range and methods of fragmentation. Mass spectrometers can acquire qualitative and quantitative information on a large scale...

  4. Quantitation of α-Lactalbumin by Liquid Chromatography Tandem Mass Spectrometry in Medicinal Adjuvant Lactose

    Directory of Open Access Journals (Sweden)

    Rui Yan

    2014-01-01

    Full Text Available Lactose is a widely used pharmaceutical excipient, sometimes irreplaceable. Traces of residual proteins left during production of lactose are potential allergen to body. The present paper describes a sensitive and specific LC-MS method for the determination of α-lactalbumin (α-La in lactose samples. Chromatographic separation was performed on an Acquity UPLC BEH300 C18 column (2.1×150 mm, 1.7 μm with an isocratic mobile phase consisting of water containing 0.1% TFA and acetonitrile containing 0.1% TFA (80 : 20, v/v. Mass spectrometric detection was achieved by a triple-quadrupole mass spectrometer equipped with an ESI interface operating in positive ionization mode. Quantitation was performed using selected ion monitoring of m/z 2364 for α-La. The calibration curve was linear from 0.2 to 10 µg/mL. The intra- and interday precisions were less than 7.6% and the accuracy ranged from 96.4 to 104.5%. The limit of quantification (LOQ was 0.15 µg/mL and the limit of detection (LOD was 0.05 µg/mL. This method was then successfully applied to investigate 6 different lactose samples. The application can provide technical preparation for the development of specification of lactose.

  5. Performance evaluation of a thermal desorption/gas chromatographic/mass spectrometric method for the characterization of waste tank headspace samples

    International Nuclear Information System (INIS)

    Ma, C.Y.; Skeen, J.T.; Dindal, A.B.; Bayne, C.K.; Jenkins, R.A.

    1997-01-01

    A thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS) method was validated for the determination of volatile organic compounds collected on carbonaceous triple sorbent traps and applied to characterize samples of headspace gases collected from underground nuclear waste storage tanks at the U.S. Department of Energy's Hanford site, in Richland, WA. Method validation used vapor-phase standards generated from 25 target analytes, including alkanes, alkyl alcohols, alkyl ketones, alkylated aromatics, and alkyl nitriles. The target analytes represent a group of compounds identified in one of the most problematic tanks. TD/GC/MS was carried out with modified injectors. Performance was characterized based on desorption efficiency, reproducibility, stability, and linearity of the calibration, method detection limits, preanalytical holding time, and quality control limits for surrogate standard recoveries. Desorption efficiencies were all greater than 82%, and the majority of the analytes (23 out of 25) had reproducibility values less than 24% near the method detection levels. The method was applied to the analysis of a total of 305 samples collected from the headspaces of 48 underground waste storge tanks. Quality control procedures were implemented to monitor sampling and TD/GC/MS method. 33 refs., 2 figs., 4 tabs

  6. Dynamic Cluster Analysis: An Unbiased Method for Identifying A+2 Element Containing Compounds in Liquid Chromatographic High-Resolution TOF Mass Spectrometric Data

    DEFF Research Database (Denmark)

    Andersen, Aaron John Christian; Hansen, Per Juel; Jørgensen, Kevin

    2016-01-01

    over 2800 u or metabolites which contained other A+2 elements, such as Cu, Ni, Mg, and Zn. It was determined that with an inter-isotopic mass accuracy of 1 ppm, in a fully automated process, using all three parameters, it is possible to specifically filter a chromatogram for S containing metabolites...

  7. Fourier Transform Mass Spectrometry: The Transformation of Modern Environmental Analyses

    Directory of Open Access Journals (Sweden)

    Lucy Lim

    2016-01-01

    Full Text Available Unknown compounds in environmental samples are difficult to identify using standard mass spectrometric methods. Fourier transform mass spectrometry (FTMS has revolutionized how environmental analyses are performed. With its unsurpassed mass accuracy, high resolution and sensitivity, researchers now have a tool for difficult and complex environmental analyses. Two features of FTMS are responsible for changing the face of how complex analyses are accomplished. First is the ability to quickly and with high mass accuracy determine the presence of unknown chemical residues in samples. For years, the field has been limited by mass spectrometric methods that were based on knowing what compounds of interest were. Secondly, by utilizing the high resolution capabilities coupled with the low detection limits of FTMS, analysts also could dilute the sample sufficiently to minimize the ionization changes from varied matrices.

  8. The use of car-borne gamma-ray spectrometric survey in a basin

    International Nuclear Information System (INIS)

    Liu Tengyao; Lu Shili; Luo Zongquan.

    1985-01-01

    This paper describes the geological results in a basin in the Inner Mongolia which were obtained by using our newly-developed and assembled car-borne gamma-ray spectrometric system. Combined with the work of regional geology and remote sensing, five relatively favourable uranium zones were located within the working area. The field procedures of car-borne gamma-ray spectrometry for less rigid regions is discussed. The gamma-ray spectrometric profiling is mainly used for regional reconnaissance. In the case of enhanced anomalious radioactivity the profiling with varying directions is adopted and the data are plotted on scale 1:50000 topographic map. It is suggested that the car-borne gamma-ray spectrometric system can be calibrated both by the pads specified for portable spectrometers and by testing site when the calibration facility for the car-borne gamma-ray spectrometric system is not available. The effect of rainfall on car-borne gamma-ray spectrometric survey and the simplified field qualitative determination of U-Ra disequilibrium are also briefly discussed

  9. Optimization of parameters for the analysis of the decabrominated diphenylether using PTV and split/splitless injectors and the consecutive setup of a dual column analysis method

    Energy Technology Data Exchange (ETDEWEB)

    Krumwiede, D.; Muenster, H.; Griep-Raming, J. [Thermo Electron Corporation, Bremen (Germany)

    2004-09-15

    Brominated diphenyl ethers (BDEs) are widely used as flame retardants in electronics industry. However, for the following reasons the mass spectrometric analysis of BDEs by high resolution magnetic sector mass spectrometry is more complicated than e.g. analysis of polychlorinated dioxins and furans: i) a high mass range from m/z 248 (mono-BDE) to m/z 960 (deca-BDE) is required, therefore demanding a reference compound that provides sufficient intensity on high m/z ions, ii) large electric jumps are necessary for window defining measurements, which demands for a stable and rugged electric mass calibration, and iii) the Deca-BDE being thermally labile, requiring optimized chromatographic methods. The first and second complication can be overcome by the correct selection of instrument parameters and by proper selection of the reference compound. Probably the most severe complication is that the deca-BDE is thermally labile, and decomposes during GC analysis. Optimized chromatographic parameters are needed in order to achieve good sensitivity for deca BDE. However, such chromatographic parameters usually sacrifice separation efficiency for the other congeners. In the following it will be shown how different chromatographic parameters influence the analytical sensitivity for the thermolabile deca BDE. Furthermore a method setup is presented, which combines optimum sensitivity for the deca BDE and at the same time good separation efficiency for mono to hepta BDE.

  10. Electrospray ionization mass spectrometric investigations of the complexation behavior of macrocyclic thiacrown ethers with bivalent transitional metals (Cu, Co, Ni and Zn).

    Science.gov (United States)

    Tsybizova, Alexandra; Tarábek, Ján; Buchta, Michal; Holý, Petr; Schröder, Detlef

    2012-10-15

    Heavy metals are both a problem for the environment and an important resource for industry. Their selective extraction by means of organic ligands therefore is an attractive topic. The coordination of three thiacrown ethers to late 3d-metal ions was investigated by a combination of electrospray ionization mass spectrometry (ESI-MS) and electron paramagnetic resonance (EPR). The mass spectrometric experiments were carried out in an ion trap mass spectrometer with an ESI source. Absolute binding constants were estimated by comparison with data for 18-crown-6/Na(+). EPR spectroscopy was used as a complementary method for investigating the Cu(I) /Cu(II) redox couple. The study found that thiacrown ethers preferentially bind traces of copper even at an excess of other metal ions (Co(II), Ni(II), and Zn(II)). The absolute association constants of the Cu(I) complexes were about 10(8) M(-1), and about two orders of magnitude lower for the other 3d-metal cations. The EPR spectra demonstrated that the reduction from Cu(II) to Cu(I) upon formation of the [(thiacrown)Cu](+) species takes place in solution. ESI-MS demonstrated that the three thiacrown ligands examined had high binding constants as well as good selectivities for copper(I) at low concentrations, and in the presence of other metal ions. By a combination of ESI-MS and EPR spectrometry it was shown that the reduction from Cu(II) to Cu(I) occurred in solution. Copyright © 2012 John Wiley & Sons, Ltd.

  11. A review on sample preparation and chromatographic determination of acephate and methamidophos in

    Directory of Open Access Journals (Sweden)

    Vijay Kumar

    2015-09-01

    Full Text Available Acephate and its metabolite methamidophos are common organophosphorus insecticide used for crop protection. High uses of acephate and methamidophos have induced health issues and environmental pollution. Their undesired presence in the environment is creating ecotoxicology and may harm human health. It is therefore essential to detect the presence of acephate and methamidophos even in trace level. In this review, we have tried to accommodate successful methods of detection of acephate and methamidophos in the different biological media. Their recovery and residue analysis in different media such as vegetables, human and animal tissues have also included. The most common method for their determination is based on chromatographic separation and identification. Among different chromatographic methods, LC and GC coupled with different detectors have used. But, they both need extensive pretreatment and cleanup procedure, before undergoing chromatographic separation and identification. LC coupled with mass spectrometry (LCMS is sometime able to detect acephate and methamidophos in ppm level.

  12. Mass Spectrometric Analyses Reveal a Central Role for Ubiquitylation in Remodeling the Arabidopsis Proteome during Photomorphogenesis.

    Science.gov (United States)

    Aguilar-Hernández, Victor; Kim, Do-Young; Stankey, Robert J; Scalf, Mark; Smith, Lloyd M; Vierstra, Richard D

    2017-06-05

    The switch from skotomorphogenesis to photomorphogenesis is a key developmental transition in the life of seed plants. While much of the underpinning proteome remodeling is driven by light-induced changes in gene expression, the proteolytic removal of specific proteins by the ubiquitin-26S proteasome system is also likely paramount. Through mass spectrometric analysis of ubiquitylated proteins affinity-purified from etiolated Arabidopsis seedlings before and after red-light irradiation, we identified a number of influential proteins whose ubiquitylation status is modified during this switch. We observed a substantial enrichment for proteins involved in auxin, abscisic acid, ethylene, and brassinosteroid signaling, peroxisome function, disease resistance, protein phosphorylation and light perception, including the phytochrome (Phy) A and phototropin photoreceptors. Soon after red-light treatment, PhyA becomes the dominant ubiquitylated species, with ubiquitin attachment sites mapped to six lysines. A PhyA mutant protected from ubiquitin addition at these sites is substantially more stable in planta upon photoconversion to Pfr and is hyperactive in driving photomorphogenesis. However, light still stimulates ubiquitylation and degradation of this mutant, implying that other attachment sites and/or proteolytic pathways exist. Collectively, we expand the catalog of ubiquitylation targets in Arabidopsis and show that this post-translational modification is central to the rewiring of plants for photoautotrophic growth. Copyright © 2017 The Author. Published by Elsevier Inc. All rights reserved.

  13. Mass-spectrometric measurements for nuclear safeguards

    International Nuclear Information System (INIS)

    Carter, J.A.; Smith, D.H.; Walker, R.L.

    1982-01-01

    The need of an on-site inspection device to provide isotopic ratio measurements led to the development of a quadrupole mass spectrometer mounted in a van. This mobile laboratory has the ability, through the use of the resin bead technique, to acquire, prepare, and analyze samples of interest to nuclear safeguards. Precision of the measurements is about 1 to 2%

  14. Development and method of use of a mass spectrometric isotope dilution analysis within the use of negative thermoionisation for determination of boron traces

    International Nuclear Information System (INIS)

    Zeininger, H.

    1984-01-01

    A mass spectrometric trace boron determination using negative thermionisation was developed. It is based on the determination of the ratio of BO 2 - isotopes ( 10 B and 11 B). A high stability and a constant intensity at a given temperature of the BO 2 - ion currents allow for a computer controlled measurement with a programmed heating. The reproducibility lies at around 0,004-0,08%. The boron determination using Mels potentiometry with a BF 4 - -ion selective electrode was used as an analytical comparison method. The MS-IDA was first used on metal samples, such as Al, Zr, and steel. Later on the boron in reagents, biological material (milk powder, spinach, water plants) and water were determined. For this material-dependent hydrolysation and separation procedures were worked out. The MS-IDA in comparison to all other analytical methods used by other collaborators offers the greatest accuracy. (RB) [de

  15. Processing of gamma-ray spectrometric logs

    International Nuclear Information System (INIS)

    Umiastowski, K.; Dumesnil, P.

    1984-10-01

    CEA (Commissariat a l'Energie Atomique) has developped a gamma-ray spectrometric tool, containing an analog-to-digital converter. This new tool permits to perform very precise uranium logs (natural gamma-ray spectrometry), neutron activation logs and litho-density logs (gamma-gamma spectrometric logs). Specific processing methods were developped to treate the particular problems of down-hole gamma-ray spectrometry. Extraction of the characteristic gamma-ray peak, even if they are superposed on the background radiation of very high intensity, is possible. This processing methode enables also to obtain geological informations contained in the continuous background of the spectrum. Computer programs are written in high level language for SIRIUS (VICTOR) and APOLLO computers. Exemples of uranium and neutron activation logs treatment are presented [fr

  16. One Sample, One Shot - Evaluation of sample preparation protocols for the mass spectrometric proteome analysis of human bile fluid without extensive fractionation.

    Science.gov (United States)

    Megger, Dominik A; Padden, Juliet; Rosowski, Kristin; Uszkoreit, Julian; Bracht, Thilo; Eisenacher, Martin; Gerges, Christian; Neuhaus, Horst; Schumacher, Brigitte; Schlaak, Jörg F; Sitek, Barbara

    2017-02-10

    The proteome analysis of bile fluid represents a promising strategy to identify biomarker candidates for various diseases of the hepatobiliary system. However, to obtain substantive results in biomarker discovery studies large patient cohorts necessarily need to be analyzed. Consequently, this would lead to an unmanageable number of samples to be analyzed if sample preparation protocols with extensive fractionation methods are applied. Hence, the performance of simple workflows allowing for "one sample, one shot" experiments have been evaluated in this study. In detail, sixteen different protocols implying modifications at the stages of desalting, delipidation, deglycosylation and tryptic digestion have been examined. Each method has been individually evaluated regarding various performance criteria and comparative analyses have been conducted to uncover possible complementarities. Here, the best performance in terms of proteome coverage has been assessed for a combination of acetone precipitation with in-gel digestion. Finally, a mapping of all obtained protein identifications with putative biomarkers for hepatocellular carcinoma (HCC) and cholangiocellular carcinoma (CCC) revealed several proteins easily detectable in bile fluid. These results can build the basis for future studies with large and well-defined patient cohorts in a more disease-related context. Human bile fluid is a proximal body fluid and supposed to be a potential source of disease markers. However, due to its biochemical composition, the proteome analysis of bile fluid still represents a challenging task and is therefore mostly conducted using extensive fractionation procedures. This in turn leads to a high number of mass spectrometric measurements for one biological sample. Considering the fact that in order to overcome the biological variability a high number of biological samples needs to be analyzed in biomarker discovery studies, this leads to the dilemma of an unmanageable number of

  17. Electronic states and nature of bonding of the molecule NiGe by all electron ab initio Hartree–Fock (HF) and configuration interaction (CI) calculations and mass spectrometric equilibrium experiments

    DEFF Research Database (Denmark)

    Shim, Irene; Kingcade, Joseph E.; Gingerich, Karl A.

    1988-01-01

    -lying electronic states of the NiGe molecule have all been characterized by the symmetry of the hole in the 3d shell of Ni. The dissociation energy of the NiGe molecule has been determined from our high temperature mass spectrometric equilibrium data in combination with the theoretical results as D [open circle] 0...... =286.8±10.9 kJ mol−1. The standard heat of formation of the NiGe molecule has been obtained as DeltaH [open circle] f,298 =514±12 kJ mol−1. The Journal of Chemical Physics is copyrighted by The American Institute of Physics....

  18. A system design of gamma-ray spectrometric data processing for gold prospecting

    International Nuclear Information System (INIS)

    Yin Xueqin; Cheng Xuchu; Fang Lianxi; Huang Zuofeng.

    1992-01-01

    Based on different correlation between gamma-ray spectrometric data and gold grade in different types of gold deposits, it is necessary and possible to establish a mathematical model of gamma-ray spectrometric data processing for predicting specific gold deposits. A system design of gamma-ray spectrometric data processing for prospecting gold deposits has been worked out according to the mathematical method and procedure of data processing. The prediction effectiveness of commonly used multiple linear regression analysis is always not ideal but regression accuracy will be evidently increased after pre-processing of the calculated weight, deviation and favorability on gamma-ray spectrometric data. This system can establish more than ten models at the same time which enable users to have more choice. Tree structure and Chinese menu prompting are adopted in this system which can be utilized separately, sub-systems at different levels can be also individually operated. It can be transplanted to data processing of other similar geological deposit models (including non-gamma ray spectrometric data). The system is rapid, accurate, simple, convenient and flexible in use, more practical and easily popularized

  19. Liquid chromatography-high resolution mass spectrometric methods for the surveillance monitoring of cyanotoxins in freshwaters.

    Science.gov (United States)

    Bogialli, Sara; Bortolini, Claudio; Di Gangi, Iole Maria; Di Gregorio, Federica Nigro; Lucentini, Luca; Favaro, Gabriella; Pastore, Paolo

    2017-08-01

    A comprehensive risk management on human exposure to cyanotoxins, whose production is actually unpredictable, is limited by reliable analytical tools for monitoring as many toxic algal metabolites as possible. Two analytical approaches based on a LC-QTOF system for target analysis and suspect screening of cyanotoxins in freshwater were presented. A database with 369 compounds belonging to cyanobacterial metabolites was developed and used for a retrospective data analysis based on high resolution mass spectrometry (HRMS). HRMS fragmentation of the suspect cyanotoxin precursor ions was subsequently performed for correctly identifying the specific variants. Alternatively, an automatic tandem HRMS analysis tailored for cyanotoxins was performed in a single chromatographic run, using the developed database as a preferred precursor ions list. Twenty-five extracts of surface and drinking waters contaminated by cyanobacteria were processed. The identification of seven uncommon microcystins (M(O)R, MC-FR, MSer 7 -YR, D-Asp 3 MSer 7 -LR, MSer 7 -LR, dmAdda-LR and dmAdda-YR) and 6 anabaenopeptins (A, B, F, MM850, MM864, oscyllamide Y) was reported. Several isobaric variants, fully separated by chromatography, were pointed out. The developed methods are proposed to be used by environmental and health agencies for strengthening the surveillance monitoring of cyanotoxins in water. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Chromatographic separations of stereoisomers

    Energy Technology Data Exchange (ETDEWEB)

    Souter, R.W.

    1985-01-01

    This text covers both diastereomers and enantiomers; describes techniques for GC, HPLC, and other chromatographic methods; and tabulates results of various applications by both techniques and compound class. It provides current knowledge about separation mechanisms and interactions of asymmetric molecules, as well as experimental and commercial materials such as columns, instruments, and derivatization reagents. The contents also include stereoisomer separations by gas chromatography. Stereoisomer separations by high-performance liquid chromatography. Stereoisomer separations by other chromatographic techniques.

  1. Feasibility of serodiagnosis of ovarian cancer by mass spectrometry

    DEFF Research Database (Denmark)

    West-Norager, M.; Bro, R.; Marini, F.

    2009-01-01

    a better analytical accuracy (81%) in the same sample set. Also, the combination of mass spectrometric data and levels of CA-125 data did not improve the predictive performance of models. In conclusion, proteomic approaches to biomarker discovery are not necessarily yielding straightforward diagnostic......The emergence of new biological disease markers from mass spectrometric studies of serum proteomes has been quite limited. There are challenges regarding the analytical and statistical procedures, preanalytical variability, and study designs. In this serological study of ovarian cancer, we apply...... classification methods in a strictly designed study with standardized sample collection procedures. A total of 265 sera from women admitted with symptoms of a pelvic mass were used for model building. We developed a rigorous approach for building classification models suitable for the highly multivariate data...

  2. Novel concepts and strategies in anticancer metallodrug development : towards oral activity, peptide conjugation and mass spectrometric applications

    Energy Technology Data Exchange (ETDEWEB)

    Meier, S.

    2013-07-01

    including top-down electrospray ionization-mass spectrometry (ESI-MS). Mass spectrometry is an invaluable tool in the analysis of molecular interactions between metallodrugs and biomolecules, such as DNA or proteins and their constituents. Furthermore, the molecular reactivity may give insight into the mode of action of a particular metallodrug or family of metallodrugs. Within the frame of this Ph.D. thesis, mass spectrometric techniques have been used to characterize the reactivity of representative (thio)pyr(id)onato RuII–p-cymene metallodrugs towards amino acids, nucleotides and proteins and an inverse correlation was found between extent of protein binding and antiproliferative activity, at least for these families of metallodrugs. Furthermore, the analysis of metallation sites of metallodrugs on proteins by mass spectrometric methods poses significant challenges in many cases due to low adduct detection efficiencies. Top-down mass spectrometric analysis is a promising approach to determine oxaliplatin binding sites on ubiquitin and different fragmentation techniques were investigated with the combination of higher energy C-trap dissociation (HCD) and electron transfer dissociation (ETD) tandem mass spectrometry yielding the highest information content. This approach led to the confirmation of methionine-1 as the primary and histidine-68 as the secondary binding site. (author) [German] Manche auf Ruthenium und Osmium als Zentralatomen basierende Koordinationsverbindungen haben sich als vielversprechende tumorhemmende Wirkstoffkandidaten erwiesen. Derzeit stellen organometallische RuII und OsII Komplexverbindungen—durch einen η6-koordinierenden Arenliganden stabilisiert—die bis dato modernste Forschungsstrategie dar, um solche Wirkstoffe zu erhalten. Im Rahmen dieser Dissertation wurden neuartige, tumorhemmende RuII– und OsII–Aren Verbindungen entdeckt und in Bezug auf ihre molekularen Wechselwirkungen mit Biomolekülen untersucht. Letzteres wurde vorab

  3. Ionic liquid-based single-drop microextraction/gas chromatographic/mass spectrometric determination of benzene, toluene, ethylbenzene and xylene isomers in waters.

    Science.gov (United States)

    Aguilera-Herrador, Eva; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel

    2008-08-01

    The direct coupling between ionic liquid-based single-drop microextraction and gas chromatography/mass spectrometry is proposed for the rapid and simple determination of benzene, toluene, ethylbenzene and xylenes isomers (BTEX) in water samples. The extraction procedure exploits not only the high affinity of the selected ionic liquid (1-methyl-3-octyl-imidazolium hexaflourophosphate) to these aromatic compounds but also its special properties like viscosity, low vapour pressure and immiscibility with water. All the variables involved in the extraction process have been studied in depth. The developed method allows the determination of these single-ring compounds in water under the reference concentration level fixed by the international legislation. In this case, limits of detection were in the range 20 ng L(-1) (obtained for benzene) and 91 ng L(-1) (for o-xylene). The repeatability of the proposed method, expressed as RSD (n=5), varied between 3.0% (o-xylene) and 5.2% (toluene).

  4. Analysis of cocaine and its metabolites from biological specimens using solid-phase extraction and positive ion chemical ionization mass spectrometry.

    Science.gov (United States)

    Crouch, D J; Alburges, M E; Spanbauer, A C; Rollins, D E; Moody, D E

    1995-10-01

    An accurate and reliable gas chromatographic-mass spectrometric method was developed to analyze tissue, whole blood, plasma, and urine samples for cocaine (COC) and its major metabolites. COC, benzoylecgonine (BZE), and ecgonine methyl ester (EME) were isolated from the biological matrix using solid-phase extraction, and the tert-butyldimethylsilyl derivatives of BZE, EME, and their deuterium-labeled internal standards were formed. Separation of the compounds was performed by capillary chromatography, and analysis was performed by positive ion chemical ionization mass spectrometry using methane and ammonia as the reagent gases. The tert-butyldimethylsilyl derivatives of BZE and EME were stable and produced mass spectral ions with higher mass-to-charge ratios than trimethylsilyl derivatives. Recovery of COC and its metabolites exceeded 80% at all three concentrations tested. Linearity of the method was established from 2.5 to 2000 microg/L. Intra-assay precision had a coefficient of variation (CV) of less than 9% for all analytes when tested at 10, 25, 100, and 200 microg/L. Interassay precision also had a CV of less than 9% for COC, BZE, and EME at 25 and 100 microg/L. At 200 microg/L, %CVs for COC, BZE, and EME were 11.5, 12.0, and 12.7, respectively. In addition to the analysis of COC, BZE, and EME, the method was used to quantitate cocaethylene and to identify norcocaine.

  5. Light-induced alterations of pineapple (Ananas comosus [L.] Merr.) juice volatiles during accelerated ageing and mass spectrometric studies into their precursors.

    Science.gov (United States)

    Steingass, Christof Björn; Glock, Mona Pia; Lieb, Veronika Maria; Carle, Reinhold

    2017-10-01

    Alterations of volatiles during accelerated light-induced ageing of pineapple juice were assessed by HS-SPME-GC-MS in a non-targeted profiling analysis over a 16-week period. Multivariate statistics permitted to reveal substantial chemical markers generally describing the effect of light storage. Volatiles generated comprised phenylpropenes, carbonyls, 2-methylthiophene, toluene, and furfural, while concentrations of methyl and ethyl esters, terpenes, and furanones decreased. In addition, the qualitative composition of phenolic compounds and glycoside-bound volatiles in selected samples was characterized by HPLC-DAD-ESI-MS n as well as HR-ESI-MS. The fresh juice contained unique pineapple metabolites such as S-p-coumaryl, S-coniferyl, S-sinapylglutathione, and structurally related derivatives. Among others, the presence of p-coumaroyl, feruloyl, and caffeoylisocitrate as well as three 4-hydroxy-2,5-dimethyl-3(2H)-furanone glycosides in pineapples could be substantiated by the HR-ESI-MS experiment. Mass spectrometric assignments of selected metabolites are presented, and putative linkages between volatiles and their precursors are established. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Marine gamma spectrometric survey

    International Nuclear Information System (INIS)

    Kostoglodov, V.V.

    1979-01-01

    Presented are theoretical problems physical and geochemical prerequisites and possibilities of practical application of the method of continuous submarine gamma-spectrometric survey and radiometric survey destined for rapid study of the surface layer of marine sediments. Shown is high efficiency and advantages of this method in comparison with traditional and widely spread in marine geology methods of bottom sediments investigation

  7. Identification and Quantification of Four Anthraquinones in Rhubarb and its Preparations by Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Dai, Heshuang; Chen, Zhiqiong; Shang, Bing; Chen, Qinhua

    2018-03-01

    A gas chromatographic-mass spectrometric (GC-MS) method was developed for the determination of four anthraquinones found in rhubarb. Chrysophanol, physcion, aloe-emodin and emodin were confirmed by GC-MS and the possible main cleavage pathways of fragment ions are discussed in this study. Rhubarb is a traditional Chinese medicinal herb which required an effective evaluation method to quantitate the four major active anthraquinone compounds described. The determinations of analytes were accomplished by GC-MS using osthole as an internal standard. MS detection was performed in selected ion monitoring mode to increase the sensitivity. The method was evaluated by a number of validation characteristics (precision, limit of detection, calibration range and recovery). The calibration ranges were all 3.2-30.0 μg/mL. This method was fully validated and showed good performances in terms of recovery (96.9-102.9%) and precision (1.4-2.9%). Finally, the method was applied to the analysis of four anthraquinones in rhubarb and its preparations in the first time.

  8. Simultaneous determination of zearalenone and its derivatives in edible vegetable oil by gel permeation chromatography and gas chromatography-triple quadrupole mass spectrometry.

    Science.gov (United States)

    Qian, Mingrong; Zhang, Hu; Wu, Liqin; Jin, Nuo; Wang, Jianmei; Jiang, Kezhi

    2015-01-01

    A sensitive gas chromatographic-triple quadrupole mass spectrometric (GC-QqQ MS) analytical method, for the determination of zearalenone and its five derivatives in edible vegetable oil, was developed. After the vegetable oil samples were prepared using gel permeation chromatography, the eluent was collected, evaporated and dried with nitrogen gas. The residue was silylated with N,O-bis-trimethylsilyltrifluoroacetamide, containing 1% trimethylchlorosilane. GC-QqQ MS was performed in the reaction-monitoring mode to confirm and quantify mycotoxins in vegetable oil. The limits of quantitation were 0.03-0.2 μg kg(-1) for the six mycotoxins. The average recoveries, measured at 2, 20 and 200 μg kg(-1), were in the range 80.3-96.5%. Zearalenone was detected in the range 5.2-184.6 μg kg(-1) in nine maize oils and at 40.7 μg kg(-1) in a rapeseed oil from the local market. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Liquid chromatographic/electrospray ionization tandem mass spectrometric study of polyphenolic composition of four cultivars of Fragaria vesca L. berries and their comparative evaluation.

    Science.gov (United States)

    Del Bubba, Massimo; Checchini, Leonardo; Chiuminatto, Ugo; Doumett, Saer; Fibbi, Donatella; Giordani, Edgardo

    2012-09-01

    High-performance liquid chromatography coupled with ion spray mass spectrometry in the tandem mode with both negative and positive ionization was used for investigating a variety of polyphenolic compounds in four genotypes of Fragaria vesca berries. About 60 phenolic compounds belonging to the compound classes of phenolic acids, ellagitannins, ellagic acid derivatives, flavonols, monomeric and oligomeric flavanols, dihydrochalcones and anthocyanins were reported, providing for the first time a quite complete picture of polyphenolic composition of F. vesca berries. Some of the polyphenols herein investigated, such as a tris-galloyl-hexahydroxydiphenoyl-hexose, two castalagin/vescalagin-like isomers and peonidin-malonylglucoside, were described for the first time. Principal component analysis applied on original HPLC-MS/MS data, acquired in multiple reaction monitoring mode, successfully discriminated the four investigated cultivars on the basis of their polyphenolic composition, highlighting the fundamental role of mass spectrometry for food characterization. Copyright © 2012 John Wiley & Sons, Ltd.

  10. Direct injection liquid chromatography/electrospray ionization mass spectrometric horse urine analysis for the quantification and confirmation of threshold substances for doping control. II. Determination of theobromine.

    Science.gov (United States)

    Vonaparti, A; Lyris, E; Panderi, I; Koupparis, M; Georgakopoulos, C

    2009-04-01

    In equine sport, theobromine is prohibited with a threshold level of 2 microg mL(-1) in urine, hence doping control laboratories have to establish quantitative and qualitative methods for its determination. Two simple liquid chromatography/mass spectrometry (LC/MS) methods for the identification and quantification of theobromine were developed and validated using the same sample preparation procedure but different mass spectrometric systems: ion trap mass spectrometry (ITMS) and time-of-flight mass spectrometry (TOFMS). Particle-free diluted urine samples were directly injected into the LC/MS systems, avoiding the time-consuming extraction step. 3-Propylxanthine was used as the internal standard. The tested linear range was 0.75-15 microg mL(-1). Matrix effects were evaluated analyzing calibration curves in water and different fortified horse urine samples. A great variation in the signal of theobromine and the internal standard was observed in different matrices. To overcome matrix effects, a standard additions calibration method was applied. The relative standard deviations of intra- and inter-day analysis were lower than 8.6 and 7.2%, respectively, for the LC/ITMS method and lower than 5.7 and 5.8%, respectively, for the LC/TOFMS method. The bias was less than 8.7% for both methods. The methods were applied to two case samples, demonstrating simplicity, accuracy and selectivity. Copyright (c) 2009 John Wiley & Sons, Ltd.

  11. Chromatographic speciation of Cr(III)-species, inter-species equilibrium isotope fractionation and improved chemical purification strategies for high-precision isotope analysis.

    Science.gov (United States)

    Larsen, K K; Wielandt, D; Schiller, M; Bizzarro, M

    2016-04-22

    Chromatographic purification of chromium (Cr), which is required for high-precision isotope analysis, is complicated by the presence of multiple Cr-species with different effective charges in the acid digested sample aliquots. The differing ion exchange selectivity and sluggish reaction rates of these species can result in incomplete Cr recovery during chromatographic purification. Because of large mass-dependent inter-species isotope fractionation, incomplete recovery can affect the accuracy of high-precision Cr isotope analysis. Here, we demonstrate widely differing cation distribution coefficients of Cr(III)-species (Cr(3+), CrCl(2+) and CrCl2(+)) with equilibrium mass-dependent isotope fractionation spanning a range of ∼1‰/amu and consistent with theory. The heaviest isotopes partition into Cr(3+), intermediates in CrCl(2+) and the lightest in CrCl2(+)/CrCl3°. Thus, for a typical reported loss of ∼25% Cr (in the form of Cr(3+)) through chromatographic purification, this translates into 185 ppm/amu offset in the stable Cr isotope ratio of the residual sample. Depending on the validity of the mass-bias correction during isotope analysis, this further results in artificial mass-independent effects in the mass-bias corrected (53)Cr/(52)Cr (μ(53)Cr* of 5.2 ppm) and (54)Cr/(52)Cr (μ(54)Cr* of 13.5 ppm) components used to infer chronometric and nucleosynthetic information in meteorites. To mitigate these fractionation effects, we developed strategic chemical sample pre-treatment procedures that ensure high and reproducible Cr recovery. This is achieved either through 1) effective promotion of Cr(3+) by >5 days exposure to HNO3H2O2 solutions at room temperature, resulting in >∼98% Cr recovery for most types of sample matrices tested using a cationic chromatographic retention strategy, or 2) formation of Cr(III)-Cl complexes through exposure to concentrated HCl at high temperature (>120 °C) for several hours, resulting in >97.5% Cr recovery using a

  12. Tandem Mass Spectrometry for Structural Identification of Sesquiterpene Alkaloids from the Stems of Dendrobium nobile Using LC-QToF.

    Science.gov (United States)

    Wang, Yan-Hong; Avula, Bharathi; Abe, Naohito; Wei, Feng; Wang, Mei; Ma, Shuang-Cheng; Ali, Zulfiqar; Elsohly, Mahmoud A; Khan, Ikhlas A

    2016-05-01

    Dendrobium nobile is one of the fundamental herbs in traditional Chinese medicine. Sesquiterpene alkaloids are the main active components in this plant. Due to weak ultraviolet absorption and low content in D. nobile, these sesquiterpene alkaloids have not been extensively studied using chromatographic methods. Herein, tandem mass spectrometry combined with liquid chromatography separation provides a tool for the identification and characterization of the alkaloids from D. nobile. A total of nine sesquiterpene alkaloids were characterized by ultrahigh-performance liquid chromatography tandem mass spectrometry. These alkaloids can be classified into two subgroups that are represented by dendrobine and nobilonine. Tandem mass spectrometric studies revealed the fragmentation pathways of these two subgroup alkaloids that were used for the identification and characterization of other alkaloids in D. nobile. Characterization of these alkaloids using accurate mass and diagnostic fragments provided a reliable methodology for the analysis of D. nobile by ultrahigh-performance liquid chromatography tandem mass spectrometry. The limit of detection was defined as the signal-to-noise ratio equal to 3 : 1. Limits of detection of dendrobine and nobilonine were less than 30 ng/mL. The developed method was applied for the analysis of various Dendrobium species and related dietary supplements. Alkaloids were identified from D. nobile, but not detected from commercial samples including 13 other Dendrobium species and the 7 dietary supplements. Georg Thieme Verlag KG Stuttgart · New York.

  13. Automated solid-phase extraction of herbicides from water for gas chromatographic-mass spectrometric analysis

    Science.gov (United States)

    Meyer, M.T.; Mills, M.S.; Thurman, E.M.

    1993-01-01

    An automated solid-phase extraction (SPE) method was developed for the pre-concentration of chloroacetanilide and triazine herbicides, and two triazine metabolites from 100-ml water samples. Breakthrough experiments for the C18 SPE cartridge show that the two triazine metabolites are not fully retained and that increasing flow-rate decreases their retention. Standard curve r2 values of 0.998-1.000 for each compound were consistently obtained and a quantitation level of 0.05 ??g/l was achieved for each compound tested. More than 10,000 surface and ground water samples have been analyzed by this method.

  14. Gas chromatographic--mass spectrometric quantitation of 16, 16-dimethyl-trans-delta 2-PGE1

    Energy Technology Data Exchange (ETDEWEB)

    Dimov, V.; Green, K.; Bygdeman, M.; Konishi, Y.; Imaki, K.; Hayashi, M.

    1983-02-01

    Di-deuterated and di-tritiated 16,16-dimethyl-trans-delta 2-PGE1 has been synthesized and used for development of a GC-MS method for quantitation of corresponding unlabelled drug in patient plasma. Although these carrier/internal standard molecules only contain 2 deuterium atoms the lower limit of detection at each injection is as low as about 40 pg. The maximum plasma levels of this drug following administration of vaginal suppositories used in clinical studies (1 mg 16,16-dimethyl-trans-delta 2-PGE1 methyl ester in 0.8 g Witepsol S-52) were 100-350 pg/ml i.e. in the same order of magnitude as earlier seen for 16,16-dimethyl-PGE2.

  15. Gas chromatographic--mass spectrometric quantitation of 16, 16-dimethyl-trans-delta 2-PGE1

    International Nuclear Information System (INIS)

    Dimov, V.; Green, K.; Bygdeman, M.; Konishi, Y.; Imaki, K.; Hayashi, M.

    1983-01-01

    Di-deuterated and di-tritiated 16,16-dimethyl-trans-delta 2-PGE1 has been synthesized and used for development of a GC-MS method for quantitation of corresponding unlabelled drug in patient plasma. Although these carrier/internal standard molecules only contain 2 deuterium atoms the lower limit of detection at each injection is as low as about 40 pg. The maximum plasma levels of this drug following administration of vaginal suppositories used in clinical studies (1 mg 16,16-dimethyl-trans-delta 2-PGE1 methyl ester in 0.8 g Witepsol S-52) were 100-350 pg/ml i.e. in the same order of magnitude as earlier seen for 16,16-dimethyl-PGE2

  16. Forensic applications of supercritical fluid chromatography - mass spectrometry.

    Science.gov (United States)

    Pauk, Volodymyr; Lemr, Karel

    2018-06-01

    Achievements of supercritical fluid chromatography with mass spectrometric detection made in the field of forensic science during the last decade are reviewed. The main topics include analysis of traditional drugs of abuse (e.g. cannabis, methamphetamine) as well as new psychoactive substances (synthetic cannabinoids, cathinones and phenethylamines), doping agents (anabolic steroids, stimulants, diuretics, analgesics etc.) and chemical warfare agents. Control of food authenticity, detection of adulteration and identification of toxic substances in food are also pointed out. Main aspects of an analytical workflow, such as sample preparation, separation and detection are discussed. A special attention is paid to the performance characteristics and validation parameters of supercritical fluid chromatography-mass spectrometric methods in comparison with other separation techniques. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Mass spectra of alicylic compounds Pt. 8

    International Nuclear Information System (INIS)

    Remane, H.; Haufe, G.

    1980-01-01

    Mass spectrometric fragmentation of C 5 -C 8 as well as C 12 ring systems of tBHC and tBMC is discussed and compared to the fragmentation of Br-, hydroxy- and methoxy cycloalkanes of similar ring sizes. The dominant processes are the splitting of the functional groups yielding M-H 2 O 1+ , M-HOCH 3 1+ and M-Br 1+ fragments, and the disintegration of the rings producing C 3 H 4 X 1+ fragments (X=Br, OH, OCH 3 ). Intensities of the more important fragments correspond to the size of the ring. The isomers can be distinguished by their mass spectra due to the inequality of the intensities of the trans- and cis-forms of BHC and BMC. Functional groups influence mass spectrometric fragmentation as it is indicated by the correlation of the fragments of the bis-functional tBHC and tBMC and the fragments of monofractional compounds. (Sz.J.)

  18. Chromatographic Methods for the Analysis of Polyphenols in Wines

    Directory of Open Access Journals (Sweden)

    Medić-Šarić, M.

    2009-03-01

    array detector (DAD. Enhancing selectivity and sensitivity for the determination of certain polyphenols requires the application of different detection techniques, such as fluorimetry (Fig. 4, electrochemistry, chemiluminescence, and/or mass spectrometry coupled with ionization techniques: electrospray (ESI, matrix-assisted laser desorption/ionization (MALDI, and atmospheric pressure chemical ionization (APCI.Gas chromatography (GC methods developed for the analysis of polyphenols require derivatization to the volatile compounds and mass-spectrometric detection in the selective ion-monitoring mode (GC/MS-SIM.A special technique, capillary electrophoresis (CE, is a powerful tool for the analysis of polyphenol contents of white and red wines, with an opportune sample preconcentration step. Micellar electrokinetic capillary chromatography (MECC has extended the utility of capillary electrophoresis to the separation of neutral analytes under the influence of an electric field. Fractionation of monomeric and polymeric pigments of higher molecular mass by gel permeation chromatography (GPC improved the analysis of these compounds by CE.

  19. Multidimensional profiling of components in complex mixtures of natural products for metabolic analysis, proof of concept: application to Quillaja saponins.

    Science.gov (United States)

    Bankefors, Johan; Nord, Lars I; Kenne, Lennart

    2010-02-01

    A method for separation and detection of major and minor components in complex mixtures has been developed, utilising two-dimensional high-performance liquid chromatography (2D-HPLC) combined with electrospray ionisation ion-trap multiple-stage mass spectrometry (ESI-ITMS(n)). Chromatographic conditions were matched with mass spectrometric detection to maximise the number of components that could be separated. The described procedure has proven useful to discern several hundreds of saponin components when applied to Quillaja saponaria Molina bark extracts. The discrimination of each saponin component relies on the fact that three coordinates (x, y, z) for each component can be derived from the retention time of the two chromatographic steps (x, y) and the m/z-values from the multiple-stage mass spectrometry (z(n), n=1, 2, ...). Thus an improved graphical representation was obtained by combining retention times from the two-stage separation with +MS(1) (z(1)) and the additional structural information from the second mass stage +MS(2) (z(2), z(3)) corresponding to the main fragment ions. By this approach three-dimensional plots can be made that reveal both the chromatographic and structural properties of a specific mixture which can be useful in fingerprinting of complex mixtures. 2009 Elsevier B.V. All rights reserved.

  20. Mass spectrometry in clinical chemistry

    International Nuclear Information System (INIS)

    Pettersen, J.E.

    1977-01-01

    A brief description is given of the functional elements of a mass spectrometer and of some currently employed mass spectrometric techniques, such as combined gas chromatography-mass spectrometry, mass chromatography, and selected ion monitoring. Various areas of application of mass spectrometry in clinical chemistry are discussed, such as inborn errors of metabolism and other metabolic disorders, intoxications, quantitative determinations of drugs, hormones, gases, and trace elements, and the use of isotope dilution mass spectrometry as a definitive method for the establishment of true values for concentrations of various compounds in reference sera. It is concluded that mass spectrometry is of great value in clinical chemistry. (Auth.)

  1. Mass spectrometric characterization of circulating and functional antigens derived from piperacillin in patients with cystic fibrosis1

    Science.gov (United States)

    Whitaker, Paul; Meng, Xiaoli; Lavergne, Sidonie N.; El-Ghaiesh, Sabah; Monshi, Manal; Earnshaw, Caroline; Peckham, Daniel; Gooi, Jimmy; Conway, Steve; Pirmohamed, Munir; Jenkins, Rosalind E.; Naisbitt, Dean J.; Park, B. Kevin

    2011-01-01

    A mechanistic understanding of the relationship between the chemistry of drug antigen formation and immune function is lacking. Thus, mass spectrometric methods were employed to detect and fully characterize circulating antigens derived from piperacillin in patients undergoing therapy and the nature of the drug derived-epitopes on protein which can function as an antigen to stimulate T-cells. Albumin modification with piperacillin in vitro resulted in the formation of two distinct haptens, one formed directly from piperacillin and a second in which the dioxopiperazine ring had undergone hydrolysis. Modification was time- and concentration-dependent, with selective modification of Lys541 observed at low concentrations, whereas at higher concentrations up to 13/59 lysine residues were modified, four of which (Lys190, 195, 432 and 541) were detected in patients’ plasma. Piperacillin-specific T-lymphocyte responses (proliferation, cytokines and granzyme-B release) were detected ex vivo with cells from hypersensitive patients, and analysis of incubation medium showed that modification of the same lysine residues in albumin occurred in situ. The antigenicity of piperacillin-modified albumin was confirmed by stimulation of T-cells with characterized synthetic conjugates. Analysis of minimally-modified T-cell stimulatory albumin conjugates revealed peptide sequences incorporating Lys190, 432 and 541 as principal functional epitopes for T-cells. This study has characterized the multiple haptenic structures on albumin in patients, and showed that they constitute functional antigenic determinants for T-cells. PMID:21606251

  2. Spectrometric techniques 2

    CERN Document Server

    Vanasse, George A

    2013-01-01

    Spectrometric Techniques, Volume II provides information pertinent to vacuum ultraviolet techniques to complete the demonstration of the diversity of methods available to the spectroscopist interested in the ultraviolet visible and infrared spectral regions. This book discusses the specific aspects of the technique of Fourier transform spectroscopy.Organized into five chapters, this volume begins with an overview of the large number of systematic effects in the recording of an interferogram. This text then examines the design approach for a Fourier transform spectrometer with focus on optics.

  3. Differentiation of Bread Made with Whole Grain and Refined Wheat (T. aestivum) Flour Using LC/MS-based chromatographic Fingerprinting and Chemometric Approaches

    Science.gov (United States)

    A fuzzy chromatography mass spectrometric (FCMS) fingerprinting method combined with chemometric analysis was established to diffrentiate between whole wheat (WW) flours and refined wheat (RW) flour, and the breads made from them. The chemical compositions of the bread samples were profiled using h...

  4. Matrix-assisted laser-desorption/ionization mass spectrometric imaging of olanzapine in a single hair using esculetin as a matrix.

    Science.gov (United States)

    Wang, Hang; Wang, Ying; Wang, Ge; Hong, Lizhi

    2017-07-15

    Matrix-assisted laser desorption/ionization-mass spectrometric imaging (MALDI-MSI) for the analysis of intact hair is a powerful tool for monitoring changes in drug consumption. The embedding of a low drug concentration in the hydrophobic hair matrix makes it difficult to extract and detect, and requires an improved method to increase detection sensitivity. In this study, an MSI method using MALDI-Fourier transform ion cyclotron resonance was developed for direct identification and imaging of olanzapine in hair samples using the positive ion mode. Following decontamination, scalp hair samples from an olanzapine user were scraped from the proximal to the distal end three times, and 5mm hair sections were fixed onto an Indium-Tin-Oxide (ITO)-coated microscopic glass slide. Esculetin (6,7-dihydroxy-2H-chromen-2-one) was used as a new hydrophobic matrix to increase the affinity, extraction and ionization efficiency of olanzapine in the hair samples. The spatial distribution of olanzapine was observed using five single hairs from the same drug user. This matrix improves the affinity of olanzapine in hair for molecular imaging with mass spectrometry. This method may provide a detection power for olanzapine to the nanogram level per 5mm hair. Time course changes in the MSI results were also compared with quantitative HPLC-MS/MS for each 5mm segment of single hair shafts selected from the MALDI target. MALDI imaging intensities in single hairs showed good semi-quantitative correlation with the results from conventional HPLC-MS/MS. MALDI-MSI is suitable for monitoring drug intake with a high time resolution. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Chromatographic retention of molybdenum, titanium and uranium complexes for removal of some interferences in inductively-coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Jiang, S.-J.; Palmieri, M.D.; Fritz, J.S.; Houk, R.S.; Iowa State Univ., of Science and Technology, Ames

    1987-01-01

    Complexes of molybdenum(VI) or titanium(IV) with N-methylfurohydroxamic acid (N-MFHA) are retained on a column packed with polystyrene/divinylbenzene. At the pH values chosen, copper, zinc and cadmium are washed rapidly through the column and are detected by inductively-coupled plasma mass spectrometry without interference from metal oxide ions of titanium or molybdenum. Detection limits are 1 to 2 μg l -1 , and analyte recoveries are essentially 100%. The resin capacity for the titanium and molybdenum complexes is sufficient for several hundred injections, and the complexes can be readily washed from the column. Uranium(VI) also forms a stable complex with N-MFHA, and ionization interference caused by excess of uranium can be avoided by chromatographic removal of the uranium complex. Various other potentially interfering elements with aqueous oxidation states of +4 or higher (e.g. Sn, W, Hf or Zr) could also be separated by this technique. 33 refs.; 4 figs.; 3 tabs

  6. Review of UV spectroscopic, chromatographic, and electrophoretic methods for the cholinesterase reactivating antidote pralidoxime (2-PAM).

    Science.gov (United States)

    John, Harald; Blum, Marc-Michael

    2012-01-01

    Pralidoxime (2-PAM) belongs to the class of monopyridinium oximes with reactivating potency on cholinesterases inhibited by phosphylating organophosphorus compounds (OPC), for example, pesticides and nerve agents. 2-PAM represents an established antidote for the therapy of anticholinesterase poisoning since the late 1950s. Quite high therapeutic concentrations in human plasma (about 13 µg/ml) lead to concentrations in urine being about 100 times higher allowing the use of less sensitive analytical techniques that were used especially in the early years after 2-PAM was introduced. In this time (mid-1950s until the end of the 1970s) 2-PAM was most often analyzed by either paper chromatography or simple UV spectroscopic techniques omitting any sample separation step. These methods were displaced completely after the establishment of column liquid chromatography in the early 1980s. Since then, diverse techniques including cation exchange, size-exclusion, reversed-phase, and ligand-exchange chromatography have been introduced. Today, the most popular method for 2-PAM quantification is ion pair chromatography often combined with UV detection representing more than 50% of all column chromatographic procedures published. Furthermore, electrophoretic approaches by paper and capillary zone electrophoresis have been successfully used but are seldom applied. This review provides a commentary and exhaustive summary of analytical techniques applied to detect 2-PAM in pharmaceutical formulations and biological samples to characterize stability and pharmacokinetics as well as decomposition and biotransformation products. Separation techniques as well as diverse detectors are discussed in appropriate detail allowing comparison of individual preferences and limitations. In addition, novel data on mass spectrometric fragmentation of 2-PAM are provided. Copyright © 2011 John Wiley & Sons, Ltd.

  7. Development of off-line layer chromatographic and total reflection X-ray fluorescence spectrometric methods for arsenic speciation

    International Nuclear Information System (INIS)

    Mihucz, Victor G.; Moricz, Agnes M.; Kroepfl, Krisztina; Szikora, Szilvia; Tatar, Eniko; Parra, Lue Meru Marco; Zaray, Gyula

    2006-01-01

    Rapid and low cost off-line thin layer chromatography-total reflection X-ray fluorescence spectrometry and overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods have been developed for separation of 25 ng of each As(III), As(V), monomethyl arsonic acid and dimethylarsinic acid applying a PEI cellulose stationary phase on plastic sheets and a mixture of acetone/acetic acid/water = 2:1:1 (v/v/v) as eluent system. The type of eluent systems, the amounts (25-1000 ng) of As species applied to PEI cellulose plates, injection volume, development distance, and flow rate (in case of overpressured thin layer chromatography) were taken into consideration for the development of the chromatographic separation. Moreover, a microdigestion method employing nitric acid for the As spots containing PEI cellulose scratched from the developed plates divided into segments was developed for the subsequent total reflection X-ray fluorescence spectrometry analysis. The method was applied for analysis of root extracts of cucumber plants grown in As(III) containing modified Hoagland nutrient solution. Both As(III) and As(V) were detected by applying the proposed thin layer chromatography/overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods

  8. Development of off-line layer chromatographic and total reflection X-ray fluorescence spectrometric methods for arsenic speciation

    Energy Technology Data Exchange (ETDEWEB)

    Mihucz, Victor G. [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary); Hungarian Satellite Centre of Trace Elements Institute to UNESCO, P. O. Box 32, H-1518 Budapest (Hungary); Moricz, Agnes M. [L. Eoetvoes University, Department of Chemical Technology and Environmental Chemistry, P.O. Box 32, H-1518 Budapest (Hungary); Kroepfl, Krisztina [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary); Szikora, Szilvia [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary); Tatar, Eniko [Hungarian Satellite Centre of Trace Elements Institute to UNESCO, P. O. Box 32, H-1518 Budapest (Hungary); L. Eoetvoes University, Department of Inorganic and Analytical Chemistry, P.O. Box 32, H-1518 Budapest (Hungary); Parra, Lue Meru Marco [Universidad Centro-occidental Lisandro Alvarado, Decanato de Agronomia, Departamento de Quimica y Suelos Unidad de Analisis Instrumental, Apartado Postal 4076, Cabudare 3023 (Venezuela); Zaray, Gyula [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary) and Hungarian Satellite Centre of Trace Elements Institute to UNESCO, P. O. Box 32, H-1518 Budapest (Hungary) and L. Eoetvoes University, Department of Inorganic and Analytical Chemistry, P.O. Box 32, H-1518 Budapest (Hungary)]. E-mail: zaray@ludens.elte.hu

    2006-11-15

    Rapid and low cost off-line thin layer chromatography-total reflection X-ray fluorescence spectrometry and overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods have been developed for separation of 25 ng of each As(III), As(V), monomethyl arsonic acid and dimethylarsinic acid applying a PEI cellulose stationary phase on plastic sheets and a mixture of acetone/acetic acid/water = 2:1:1 (v/v/v) as eluent system. The type of eluent systems, the amounts (25-1000 ng) of As species applied to PEI cellulose plates, injection volume, development distance, and flow rate (in case of overpressured thin layer chromatography) were taken into consideration for the development of the chromatographic separation. Moreover, a microdigestion method employing nitric acid for the As spots containing PEI cellulose scratched from the developed plates divided into segments was developed for the subsequent total reflection X-ray fluorescence spectrometry analysis. The method was applied for analysis of root extracts of cucumber plants grown in As(III) containing modified Hoagland nutrient solution. Both As(III) and As(V) were detected by applying the proposed thin layer chromatography/overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods.

  9. Optimization of chromatographic conditions for determination of aflatoxin B1, B2, G1 and G2 by using liquid chromatography-mass Spectrometry

    Science.gov (United States)

    Ramadhaningtyas, Dillani Putri; Aryana, Nurhani; Aristiawan, Yosi; Styarini, Dyah

    2017-11-01

    The optimization of instrument condition and chromatographic separation for analysis of aflatoxin B1, B2, G1 and G2 using liquid chromatography tandem with mass spectrometer detector was conducted in the aim to provide more accurate and reliable analysis results. The aflatoxin known to be serious threat for human health as it is classified as the carcinogenic compounds. The aflatoxin B1, B2, G1 and G2 were selected due to its extensive contamination in various agricultural commodities. The best chromatographic separation was obtained using C-18 column with gradient elution of solvent 5 mM ammonium acetate and 0.1% formic acid in methanol at 7 minutes runtime analysis. The linearity of the detector showed satisfied results as the coefficient determination found to be 0.9994, 0.9996, 0.9998 and 0.9987 for aflatoxin B1, G1, B2, and G2 respectively in the range concentration from 1 to 20 ng/g. The quantifier ion selected for the aflatoxin B1, B2, G1 and G2 was m/z 285.1, 259, 243 and 313 respectively. The instrument precision at these quantifier ions also showed satisfied result with %RSD was around 3.4 to 6.8%. The optimized method present in this study can be used for further sample analysis.

  10. Integrative Mass Spectrometry Approaches to Monitor Protein Structures, Modifications, and Interactions

    NARCIS (Netherlands)

    Lössl, P.

    2017-01-01

    This thesis illustrates the current standing of mass spectrometry (MS) in molecular and structural biology. The primary aim of the herein described research is to facilitate protein characterization by combining mass spectrometric methods among each other and with complementary analytical

  11. Determination of phenyl-N-methylcarbamates and their hydrolysis products in water, using solid-phase extraction and reversed-phase liquid chromatography with UV and electrospray mass spectrometric detection

    International Nuclear Information System (INIS)

    El Atrache, L.L.; Sabbah, S.

    2003-01-01

    In this study, eight phenyl-N-methylcarbamates (PNMCs) were considered. Reversed-phase LC was set up for UV and mass spectrometry (MS) detection mode. Gradient elution was used, and the mobile phase was composed of acetonitrile and water. UV-vis was performed at 220 nm. The method was tested with different reversed-phase columns. Comparison between chromatographic parameters: retention time (t R ), resolution (R S ), and selectivity (α) was established. Hydrolysis kinetics of three of the PNMCs were reported. The major hydrolysis products were determined by LC-UV, and the effect of pH on hydrolysis was also studied. Also, chromatographic separation of a mixture of PNMCs and four of their hydrolysis products was carried out. The preconcentration of 12 studied solutes was realized by solid-phase extraction. C18 extraction cartridges of 1 g were used to extract solutes from a 100 mL volume of tap and surface water spiked at 10 μg/L. The recoveries were, respectively, between 68-86% and 62-83% with relative a standard deviation of less than 11%. Limits of detection (LODs) and limits of quantitation (LOQs) ranged, respectively, from 1-4 μg/L and from 4-10 μg/L. Since standard UV detection does not provide adequate selectivity for water samples, an electrospray (ES)-MS instrument equipped with a triple quadrupole mass filter was used. MS data acquisition was performed by a time-scheduled, selected-ion monitoring (SIM) program. Limits of quantitation gave values between 0.1-0.5 μg/L. (author)

  12. On the interference of Kr during carbon isotope analysis of methane using continuous-flow combustion–isotope ratio mass spectrometry

    Directory of Open Access Journals (Sweden)

    J. Schmitt

    2013-05-01

    Full Text Available Stable carbon isotope analysis of methane (δ13C of CH4 on atmospheric samples is one key method to constrain the current and past atmospheric CH4 budget. A frequently applied measurement technique is gas chromatography (GC isotope ratio mass spectrometry (IRMS coupled to a combustion-preconcentration unit. This report shows that the atmospheric trace gas krypton (Kr can severely interfere during the mass spectrometric measurement, leading to significant biases in δ13C of CH4, if krypton is not sufficiently separated during the analysis. According to our experiments, the krypton interference is likely composed of two individual effects, with the lateral tailing of the doubly charged 86Kr peak affecting the neighbouring m/z 44 and partially the m/z 45 Faraday cups. Additionally, a broad signal affecting m/z 45 and especially m/z 46 is assumed to result from scattered ions of singly charged krypton. The introduced bias in the measured isotope ratios is dependent on the chromatographic separation, the krypton-to-CH4 mixing ratio in the sample, the focusing of the mass spectrometer as well as the detector configuration and can amount to up to several per mil in δ13C. Apart from technical solutions to avoid this interference, we present correction routines to a posteriori remove the bias.

  13. Determination of plutonium isotopes (238Pu, 239Pu, 240Pu, 241Pu) in environmental samples using radiochemical separation combined with radiometric and mass spectrometric measurements

    DEFF Research Database (Denmark)

    Xu, Yihong; Qiao, Jixin; Hou, Xiaolin

    2014-01-01

    counting and alpha spectrometry) and inductively coupled plasma mass spectrometry (ICP-MS) were applied for the measurement of plutonium isotopes. The decontamination factors for uranium were significantly improved up to 7.5×105 for 20 g soil compared to the level reported in the literature......, this is critical for the measurement of plutonium isotopes using mass spectrometric technique. Although the chemical yield of Pu in the entire procedure is about 55%, the analytical results of IAEA soil 6 and IAEA-367 in this work are in a good agreement with the values reported in the literature or reference......Pu. However, it is impossible to measure 238Pu using ICP-MS in environmental samples even a decontamination factor as high as 106 for uranium was obtained by chemical separation....

  14. Dissipation, half-lives, and mass spectrometric identification of chlorpyrifos and its two metabolites on field-grown collard and kale.

    Science.gov (United States)

    Antonious, George F; Turley, Eric T; Abubakari, Mutari; Snyder, John C

    2017-04-03

    The persistence and fate of chlorpyrifos and its two metabolites, chlorpyrifos-oxon and the 3, 5, 6-trichloro-2-pyridinol (TCP) break-down product were investigated on kale and collard leaves under field conditions. A simultaneous extraction and quantification procedure was developed for chrorpyrifos and its two main metabolites. Residues of chlorpyrifos, chlorpyrifos oxon, and TCP were determined using a gas chromatograph (GC) equipped with an electron capture detector (GC/ECD). Chlorpyrifos metabolites were detectable up to 23 days following application. Residues were confirmed using a GC equipped with a mass selective detector (GC/MSD) in total ion mode. Initial residues of chlorpyrifos were greater on collard (14.5 µg g -1 ) than kale (8.2 µg g -1 ) corresponding to half-lives (T 1/2 ) values of 7.4 and 2.2 days, respectively. TCP, the hydrolysis product, was more persistent on collards with an estimated T 1/2 of 6.5 days compared to kale (T 1/2 of 1.9 days).

  15. Mass spectrometric analysis of helium in stainless steel

    International Nuclear Information System (INIS)

    Isagawa, Hiroto; Wada, Yukio; Asakura, Yoshiro; Tsuji, Nobuo; Sato, Hitoshi; Tsutsumi, Kenichi

    1974-01-01

    Vacuum fusion mass-spectrometry was adopted for the analysis of helium in stainless steel. Samples were heated in a vacuum crucible, and helium in the samples was extracted and collected into a reservoir tank. The gas was then introduced through an orifice into a mass spectrometer, where the amount of helium was determined. The maspeq 070 quadrupole type mass spectrometer made by Shimazu Seisakusho, Ltd. was used. The resolving power was 150, and the mass range of the apparatus was 0-150. The determination limit of helium was about 2 x 10 -3 μg when standard helium gas was analyzed, and was about 10 -2 μg when the helium in stainless steel was analyzed. The relative standard deviation of helium intensity in repetitive measurement was about 2% in the amount of helium of 0.05 μg. Helium was injected into stainless steel by means of alpha particle irradiation with a cyclotron. The amount of helium in stainless steel was then determined. The energy of alpha particles was 34 MeV, and the beam area was 10 mm x 10 mm. The experimental data were higher than the expected value in one case, and were lower in the other case. This difference was attributable to the fluctuation of alpha particle beam, misplacement of sample plates, and unevenness of the alpha beam. (Fukutomi, T.)

  16. The leakage problem in vacuum system. Realization of a mass spectrometer detecting leaks; Le probleme des fuites en technique du vide. Realisation d'un spectrometre de masse detecteur de fuite

    Energy Technology Data Exchange (ETDEWEB)

    Geller, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1954-11-15

    In the first part of this paper we consider the problem of leaks in vacuum systems, and their detection. We consider in particular the method of detection by means of a helium spectrometer. The second part deals with the experimental set p. The analyser and the ion source have been studied in great detail, and we have also discussed the technological and mechanical aspects of the apparatus and its performances. (author) [French] Dans la premiere partie de ce travail, nous traitons le probleme des fuites en technique du vide et leur detection en general. La methode de detection par spectrometre a helium y est envisagee plus particulierement. La deuxieme partie de l'article est consacree a la realisation du spectrometre. Le tube analyseur et la source d'ions y sont etudies en detail. Nous exposons de meme les conceptions technologiques et mecaniques de l'appareil ainsi que ses performances. (auteur)

  17. Analysis of phenolic compounds from different morphological parts of Helichrysum devium by liquid chromatography with on-line UV and electrospray ionization mass spectrometric detection.

    Science.gov (United States)

    Gouveia, Sandra C; Castilho, Paula C

    2009-12-01

    A simple and rapid method has been used for the screening and identification of the main phenolic compounds from Helichrysum devium using high-performance liquid chromatography with on-line UV and electrospray ionization mass spectrometric detection (LC-DAD/ESI-MS(n)). The total aerial parts and different morphological parts of the plant, namely leaves, flowers and stems, were analyzed separately. A total of 34 compounds present in the methanolic extract from Helichrysum devium were identified or tentatively characterized based on their UV and mass spectra and retention times. Three of these compounds were positively identified by comparison with reference standards. The phenolic compounds included derivatives of quinic acid, O-glycosylated flavonoids, a caffeic acid derivative and a protocatechuic acid derivative. The characteristic loss of 206 Da from malonylcaffeoyl quinic acid was used to confirm the malonyl linkage to the caffeoyl group. This contribution presents one of the first reports on the analysis of phenolic compounds from Helichrysum devium using LC-DAD/ESI-MS(n) and highlights the prominence of quinic acid derivatives as the main group of phenolic compounds present in these extracts. We also provide evidence that the methanolic extract from the flowers was significantly more complex when compared to that of other morphological parts. Copyright 2009 John Wiley & Sons, Ltd.

  18. Chromatographic hydrogen isotope separation

    International Nuclear Information System (INIS)

    Aldridge, F.T.

    1983-01-01

    Intermetallic compounds with the CaCu5 type of crystal structure, particularly LaNiCo and CaNi5, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation column. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale multi-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen can produce large quantities of heavy water at an effective cost for use in heavy water reactors

  19. Chromatographic hydrogen isotope separation

    International Nuclear Information System (INIS)

    Aldridge, F.T.

    1981-01-01

    Intermetallic compounds with the CaCu5 type of crystal structure , particularly LaNiCo and CaNi5, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation colum. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale mutli-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen can produce large quantities of heavy water at an effective cost for use in heavy water reactors

  20. Spectrometric control of radionuclides production parameters

    International Nuclear Information System (INIS)

    Zhuk, I.; Potarenko, A.; Yarochevich, O.; Hluboky, N.; Kerko, P.; Bogdanov, V.; Dyatel, N.

    2006-01-01

    Full text: A radioactive preparations and sources are widely used all over the world for scientific, industrial and medical purposes. These preparations in Belarus are planned to produce by the Joint Belarussian-Russian Closed Joint Stock Company 'Isotope technologies' (CJSC IT). The company was created in 1998 by two leading scientific centers-SSI 'Joint Institute of Power and Nuclear Research-Sosny' the National Academy of Sciences of Belarus and the State Center of Science of the Russian Federation 'Scientific research institute of nuclear reactors'. One of the mainstream directions in CJSC IT activities is production of radioactive preparations for the industrial and scientific application (such as 133 Ba, 109 Cd, 63 Ni, 60 Co) and for the medical purposes (such as 19 '2Ir, 60 Co). All radioactive preparations have a good export potential and adequate to modern technical and consumer requirements. X-γ spectrometric analysis of considered radioactive sources is one of the basic methods for quality control of radioactive sources. At present, we are developing x-γ spectrometric support of purification process from contaminating radionuclides of 109 Cd -γ preparation and 63 Ni - β preparation. Work on x-γ spectrometric quality control of 133 Ba preparation is carried out. The description of the used equipment is given. Techniques of contaminating radionuclides determination (contents ∼10 - '6 from activity of the basic radionuclide) are presented. Problems of the choice of geometry of measurements of sources with activity about 10 7 -10 9 Bq and possible sources of errors are discussed. (author)

  1. Toward consensus in the analysis of urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine as a noninvasive biomarker of oxidative stress

    DEFF Research Database (Denmark)

    Urinary (DNA) Lesion Analysis, European Standards Committee on; Evans, Mark D; Olinski, Ryszard

    2010-01-01

    Of the DNA-derived biomarkers of oxidative stress, urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) is the most frequently measured. However, there is significant discrepancy between chromatographic and immunoassay approaches, and intratechnique agreement among all available chromatography...... as mass spectrometric (MS), electrochemical detection (EC), or enzyme-linked immunosorbant assay (ELISA). Overall, there was good within-technique agreement, with the majority of laboratories' results lying within 1 sd of their consensus mean. However, ELISA showed more within-technique variation than did...... the chromatographic techniques and, for the urine samples, reported higher values. Bland-Altman plots revealed good agreement between MS and EC methods but concentration-dependent deviation for ELISA. All methods ranked urine samples according to concentration similarly. Creatinine levels are routinely used...

  2. Qualitative and Quantitative Characterization of Therapeutic Antibodies by Native Mass Spectrometry

    NARCIS (Netherlands)

    Rosati, S

    2014-01-01

    This thesis describes the development of novel mass spectrometric methods for the analysis of therapeutic monoclonal antibodies. The first chapter of my thesis introduces the reader to the two main subjects discussed in this thesis: native mass spectrometry and therapeutic monoclonal antibodies.

  3. Sample preparation and fractionation for proteome analysis and cancer biomarker discovery by mass spectrometry.

    Science.gov (United States)

    Ahmed, Farid E

    2009-03-01

    Sample preparation and fractionation technologies are one of the most crucial processes in proteomic analysis and biomarker discovery in solubilized samples. Chromatographic or electrophoretic proteomic technologies are also available for separation of cellular protein components. There are, however, considerable limitations in currently available proteomic technologies as none of them allows for the analysis of the entire proteome in a simple step because of the large number of peptides, and because of the wide concentration dynamic range of the proteome in clinical blood samples. The results of any undertaken experiment depend on the condition of the starting material. Therefore, proper experimental design and pertinent sample preparation is essential to obtain meaningful results, particularly in comparative clinical proteomics in which one is looking for minor differences between experimental (diseased) and control (nondiseased) samples. This review discusses problems associated with general and specialized strategies of sample preparation and fractionation, dealing with samples that are solution or suspension, in a frozen tissue state, or formalin-preserved tissue archival samples, and illustrates how sample processing might influence detection with mass spectrometric techniques. Strategies that dramatically improve the potential for cancer biomarker discovery in minimally invasive, blood-collected human samples are also presented.

  4. Quantification in untargeted mass spectrometry-based metabolomics

    NARCIS (Netherlands)

    Kloet, Frans Meindert van der

    2014-01-01

    The aim of this thesis was to develop concepts and methods to extract qualitative and quantitative information about metabolites from untargeted mass spectrometric data of biological samples. Several typical challenges in data handling were addressed that prevent a straightforward interpretation

  5. Particle desorption mass spectrometric surface characterization

    International Nuclear Information System (INIS)

    Summers, W.R.

    1986-01-01

    The feasibility of utilizing 252 Cf-Particle Desorption Mass Spectrometry (PDMS) to characterize the surface region of solid samples has been evaluated. The PDMS experiment was adapted to an ultrahigh vacuum (UHV) environment and was configured so as to allow the analysis of thick as well as thin samples. This apparatus included an in situ sputter cleaning/depth profiling facility. The mass resolution was variable from 300 to 200 at 133 daltons by changing the drift length from 27 cm to 20 cm. Desorbed ions were focused by using either a dual grid assembly or an einzel lens. The overall instrumental transmission efficiency with the einzel lens operative was approximately 50%. The applicability of 252 Cf-PDMS to samples that were thick and insulating was demonstrated in the analysis of geological specimens. Pollucite, Microcline, Amblygonite, and Lepidolite were analyzed without complications associated with sample thickness or charge accumulation. Substitution occurring between the alkali metals in the environment was observed by PDMS and was corroborated by SIMS, XPS, and EMP analyses. The analysis of NBM SRM glasses addressed the suitability of combining the PDMS technique was sputter etching. This application demonstrated the ability of this technique to sense changes in the chemical environment brought about by sputter cleaning. The analysis of these samples also allowed the estimation of detection limits for lithium, rubidium, and cesium in a glass matrix as 300 ppm, 400 ppm, and 400 ppm, respectively. Sputter depth profiling combined with 252 Cf-PDMS analysis of an aluminum layer on a silicon substrate established the utility of the PDMS technique in surface characterization

  6. Optimization of the gas chromatographic separations

    International Nuclear Information System (INIS)

    Gasco Sanchez, L.

    1973-01-01

    A review and a critical study on the optimization of the gas chromatographic separations are made. After dealing with the fundamental gas chromatographic equations, some methods of expressing column performances are discussed: performance indices, performance parameters, resolution and effective plate number per unit time. This is completed with a comparative study on performances of various types of columns. Moreover, optimization methods for operating chromatographic conditions are extensively dealt with: as resolution optimization, separation time, and normalization techniques for the time of analysis in order to achieve the maximum resolution at constant time. Finally, some others non operating parameters such as: selectivity of stationary phases, column preparation and optimization methods by means of computers are studied. (Author) 68 refs

  7. A Small-Scale Low-Cost Gas Chromatograph

    Science.gov (United States)

    Gros, Natasa; Vrtacnik, Margareta

    2005-01-01

    The design and application of a small-scale portable gas chromatograph for learning of the basic concepts of chromatography is described. The apparatus consists of two basic separable units, which includes a chromatographic unit and an electronic unit.

  8. Gas chromatographic-mass spectrometric analysis of urinary volatile organic metabolites: Optimization of the HS-SPME procedure and sample storage conditions.

    Science.gov (United States)

    Živković Semren, Tanja; Brčić Karačonji, Irena; Safner, Toni; Brajenović, Nataša; Tariba Lovaković, Blanka; Pizent, Alica

    2018-01-01

    Non-targeted metabolomics research of human volatile urinary metabolome can be used to identify potential biomarkers associated with the changes in metabolism related to various health disorders. To ensure reliable analysis of urinary volatile organic metabolites (VOMs) by gas chromatography-mass spectrometry (GC-MS), parameters affecting the headspace-solid phase microextraction (HS-SPME) procedure have been evaluated and optimized. The influence of incubation and extraction temperatures and times, coating fibre material and salt addition on SPME efficiency was investigated by multivariate optimization methods using reduced factorial and Doehlert matrix designs. The results showed optimum values for temperature to be 60°C, extraction time 50min, and incubation time 35min. The proposed conditions were applied to investigate urine samples' stability regarding different storage conditions and freeze-thaw processes. The sum of peak areas of urine samples stored at 4°C, -20°C, and -80°C up to six months showed a time dependent decrease over time although storage at -80°C resulted in a slight non-significant reduction comparing to the fresh sample. However, due to the volatile nature of the analysed compounds, more than two cycles of freezing/thawing of the sample stored for six months at -80°C should be avoided whenever possible. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Analysis of antioxidants in insulation cladding of copper wire: a comparison of different mass spectrometric techniques (ESI-IT, MALDI-RTOF and RTOF-SIMS).

    Science.gov (United States)

    Schnöller, Johannes; Pittenauer, Ernst; Hutter, Herbert; Allmaier, Günter

    2009-12-01

    Commercial copper wire and its polymer insulation cladding was investigated for the presence of three synthetic antioxidants (ADK STAB AO412S, Irganox 1010 and Irganox MD 1024) by three different mass spectrometric techniques including electrospray ionization-ion trap-mass spectrometry (ESI-IT-MS), matrix-assisted laser desorption/ionization reflectron time-of-flight (TOF) mass spectrometry (MALDI-RTOF-MS) and reflectron TOF secondary ion mass spectrometry (RTOF-SIMS). The samples were analyzed either directly without any treatment (RTOF-SIMS) or after a simple liquid/liquid extraction step (ESI-IT-MS, MALDI-RTOF-MS and RTOF-SIMS). Direct analysis of the copper wire itself or of the insulation cladding by RTOF-SIMS allowed the detection of at least two of the three antioxidants but at rather low sensitivity as molecular radical cations and with fairly strong fragmentation (due to the highly energetic ion beam of the primary ion gun). ESI-IT- and MALDI-RTOF-MS-generated abundant protonated and/or cationized molecules (ammoniated or sodiated) from the liquid/liquid extract. Only ESI-IT-MS allowed simultaneous detection of all three analytes in the extract of insulation claddings. The latter two so-called 'soft' desorption/ionization techniques exhibited intense fragmentation only by applying low-energy collision-induced dissociation (CID) tandem MS on a multistage ion trap-instrument and high-energy CID on a tandem TOF-instrument (TOF/RTOF), respectively. Strong differences in the fragmentation behavior of the three analytes could be observed between the different CID spectra obtained from either the IT-instrument (collision energy in the very low eV range) or the TOF/RTOF-instrument (collision energy 20 keV), but both delivered important structural information. Copyright 2009 John Wiley & Sons, Ltd.

  10. MULTI-DIMENSIONAL MASS SPECTROMETRY-BASED SHOTGUN LIPIDOMICS AND NOVEL STRATEGIES FOR LIPIDOMIC ANALYSES

    Science.gov (United States)

    Han, Xianlin; Yang, Kui; Gross, Richard W.

    2011-01-01

    Since our last comprehensive review on multi-dimensional mass spectrometry-based shotgun lipidomics (Mass Spectrom. Rev. 24 (2005), 367), many new developments in the field of lipidomics have occurred. These developments include new strategies and refinements for shotgun lipidomic approaches that use direct infusion, including novel fragmentation strategies, identification of multiple new informative dimensions for mass spectrometric interrogation, and the development of new bioinformatic approaches for enhanced identification and quantitation of the individual molecular constituents that comprise each cell’s lipidome. Concurrently, advances in liquid chromatography-based platforms and novel strategies for quantitative matrix-assisted laser desorption/ionization mass spectrometry for lipidomic analyses have been developed. Through the synergistic use of this repertoire of new mass spectrometric approaches, the power and scope of lipidomics has been greatly expanded to accelerate progress toward the comprehensive understanding of the pleiotropic roles of lipids in biological systems. PMID:21755525

  11. Emission spectrometric isotope analyzer

    International Nuclear Information System (INIS)

    Mauersberger, K.; Meier, G.; Nitschke, W.; Rose, W.; Schmidt, G.; Rahm, N.; Andrae, G.; Krieg, D.; Kuefner, W.; Tamme, G.; Wichlacz, D.

    1982-01-01

    An emission spectrometric isotope analyzer has been designed for determining relative abundances of stable isotopes in gaseous samples in discharge tubes, in liquid samples, and in flowing gaseous samples. It consists of a high-frequency generator, a device for defined positioning of discharge tubes, a grating monochromator with oscillating slit and signal converter, signal generator, window discriminator, AND connection, read-out display, oscillograph, gas dosing device and chemical conversion system with carrier gas source and vacuum pump

  12. Proceedings of the relevance of mass spectrometry to DNA sequence determination: Research needs for the Human Genome Program

    Energy Technology Data Exchange (ETDEWEB)

    Edmonds, C.G.; Smith, R.D. (Pacific Northwest Lab., Richland, WA (USA)); Smith, L.M. (Wisconsin Univ., Madison, WI (USA))

    1990-11-01

    A workshop was sponsored for the US Department of Energy (DOE), Office of Health and Environmental Research by Pacific Northwest Laboratory, April 4--5, 1990, in Seattle, Washington, to examine the potential role of mass spectrometry in the joint DOE/National Institutes of Health (NIH) Human Genome Program. The workshop was occasioned by recent developments in mass spectrometry that are providing new levels for selectivity, sensitivity, and, in particular, new methods of ionization appropriate for large biopolymers such as DNA. During discussions, three general mass spectrometric approaches to the determination of DNA sequence were considered: (1) the mass spectrometric detection of isotopic labels from DNA sequencing mixtures separated using gel electrophoresis, (2) the direct mass spectrometric analysis from direct ionization of unfractionated sequencing mixtures where the measured mass of the constituents functions to identify and order the base sequence (replacing separation by gel electrophoresis), and (3) an approach in which a single highly charged molecular ion of a large DNA segment produced is rapidly sequenced in an ion cyclotron resonance ion trap. The consensus of the workshop was that, on the basis of the new developments, mass spectrometry has the potential to provide the substantial increases in sequencing speed required for the Human Genome Program. 66 refs., 3 tabs.

  13. Mass-spectrometric identification of T-kininogen I/thiostatin as an acute-phase inflammatory protein suppressed by curcumin and capsaicin.

    Science.gov (United States)

    Joe, Bina; Nagaraju, Anitha; Gowda, Lalitha R; Basrur, Venkatesha; Lokesh, Belur R

    2014-01-01

    Curcumin and capsaicin are dietary xenobiotics with well-documented anti-inflammatory properties. Previously, the beneficial effect of these spice principles in lowering chronic inflammation was demonstrated using a rat experimental model for arthritis. The extent of lowering of arthritic index by the spice principles was associated with a significant shift in macrophage function favoring the reduction of pro-inflammatory molecules such as reactive oxygen species and production and release of anti-inflammatory metabolites of arachidonic acid. Beyond the cellular effects on macrophage function, oral administration of curcumin and capsaicin caused alterations in serum protein profiles of rats injected with adjuvant to develop arthritis. Specifically, a 72 kDa acidic glycoprotein, GpA72, which was elevated in pre-arthritic rats, was significantly lowered by feeding either curcumin or capsaicin to the rats. Employing the tandem mass spectrometric approach for direct sequencing of peptides, here we report the identification of GpA72 as T-kininogen I also known as Thiostatin. Since T-kininogen I is an early acute-phase protein, we additionally tested the efficiency of curcumin and capsaicin to mediate the inflammatory response in an acute phase model. The results demonstrate that curcumin and capsaicin lower the acute-phase inflammatory response, the molecular mechanism for which is, in part, mediated by pathways associated with the lowering of T-kininogen I.

  14. Mass-spectrometric identification of T-kininogen I/thiostatin as an acute-phase inflammatory protein suppressed by curcumin and capsaicin.

    Directory of Open Access Journals (Sweden)

    Bina Joe

    Full Text Available Curcumin and capsaicin are dietary xenobiotics with well-documented anti-inflammatory properties. Previously, the beneficial effect of these spice principles in lowering chronic inflammation was demonstrated using a rat experimental model for arthritis. The extent of lowering of arthritic index by the spice principles was associated with a significant shift in macrophage function favoring the reduction of pro-inflammatory molecules such as reactive oxygen species and production and release of anti-inflammatory metabolites of arachidonic acid. Beyond the cellular effects on macrophage function, oral administration of curcumin and capsaicin caused alterations in serum protein profiles of rats injected with adjuvant to develop arthritis. Specifically, a 72 kDa acidic glycoprotein, GpA72, which was elevated in pre-arthritic rats, was significantly lowered by feeding either curcumin or capsaicin to the rats. Employing the tandem mass spectrometric approach for direct sequencing of peptides, here we report the identification of GpA72 as T-kininogen I also known as Thiostatin. Since T-kininogen I is an early acute-phase protein, we additionally tested the efficiency of curcumin and capsaicin to mediate the inflammatory response in an acute phase model. The results demonstrate that curcumin and capsaicin lower the acute-phase inflammatory response, the molecular mechanism for which is, in part, mediated by pathways associated with the lowering of T-kininogen I.

  15. Rapid process development of chromatographic process using direct analysis in real time mass spectrometry as a process analytical technology tool.

    Science.gov (United States)

    Yan, Binjun; Chen, Teng; Xu, Zhilin; Qu, Haibin

    2014-06-01

    The concept of quality by design (QbD) is widely applied in the process development of pharmaceuticals. However, the additional cost and time have caused some resistance about QbD implementation. To show a possible solution, this work proposed a rapid process development method, which used direct analysis in real time mass spectrometry (DART-MS) as a process analytical technology (PAT) tool for studying the chromatographic process of Ginkgo biloba L., as an example. The breakthrough curves were fast determined by DART-MS at-line. A high correlation coefficient of 0.9520 was found between the concentrations of ginkgolide A determined by DART-MS and HPLC. Based on the PAT tool, the impacts of process parameters on the adsorption capacity were discovered rapidly, which showed a decreased adsorption capacity with the increase of the flow rate. This work has shown the feasibility and advantages of integrating PAT into QbD implementation for rapid process development. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Linear mass reflectron

    International Nuclear Information System (INIS)

    Mamyrin, B.A.; Shmikk, D.V.

    1979-01-01

    A description and operating principle of a linear mass reflectron with V-form trajectory of ion motion -a new non-magnetic time-of-flight mass spectrometer with high resolution are presented. The ion-optical system of the device consists of an ion source with ionization by electron shock, of accelerating gaps, reflector gaps, a drift space and ion detector. Ions move in the linear mass refraction along the trajectories parallel to the axis of the analyzer chamber. The results of investigations into the experimental device are given. With an ion drift length of 0.6 m the device resolution is 1200 with respect to the peak width at half-height. Small-sized mass spectrometric transducers with high resolution and sensitivity may be designed on the base of the linear mass reflectron principle

  17. A Gas Chromatographic System for the Detection of Ethylene Gas Using Ambient Air as a Carrier Gas.

    Science.gov (United States)

    Zaidi, Nayyer Abbas; Tahir, Muhammad Waseem; Vellekoop, Michael J; Lang, Walter

    2017-10-07

    Ethylene gas is a naturally occurring gas that has an influence on the shelf life of fruit during their transportation in cargo ships. An unintentional exposure of ethylene gas during transportation results in a loss of fruit. A gas chromatographic system is presented here for the detection of ethylene gas. The gas chromatographic system was assembled using a preconcentrator, a printed 3D printed gas chromatographic column, a humidity sensor, solenoid valves, and an electrochemical ethylene gas sensor. Ambient air was used as a carrier gas in the gas chromatographic system. The flow rate was fixed to 10 sccm. It was generated through a mini-pump connected in series with a mass flow controller. The metal oxide gas sensor is discussed with its limitation in ambient air. The results show the chromatogram obtained from metal oxide gas sensor has low stability, drifts, and has uncertain peaks, while the chromatogram from the electrochemical sensor is stable and precise. Furthermore, ethylene gas measurements at higher ppb concentration and at lower ppb concentration were demonstrated with the electrochemical ethylene gas sensor. The system separates ethylene gas and humidity. The chromatograms obtained from the system are stable, and the results are 1.2% repeatable in five similar measurements. The statistical calculation of the gas chromatographic system shows that a concentration of 2.3 ppb of ethylene gas can be detected through this system.

  18. Car-borne multichannel gamma-ray spectrometric system model CZD-6

    International Nuclear Information System (INIS)

    Lu Shili; Zhai Yugui; Ma Yanfang; Jiao Cangwen; Zhang Biao

    1998-01-01

    The car-borne multichannel gamma-ray spectrometric system Mode CZD-6 is composed of a HDY-256 of portable multichannel gamma-ray spectrometer developed by the Beijing Research Institute of Uranium Geology and a large volume scintillation detector. the position for each measurement point is determined by the GPS instrument. Its latitude and longitude, as well as measured 256 channels of γ-spectrometric data are collected by a notebook computer, which can show the 256 channels of spectra for each point during measuring processes. The complete system can be loaded in a field car. This system has been used to environmental radioactive monitoring after calibration by airborne radiometric models in Shijiazhuang, Hebei province. A lot of data confirm that the system works stably and reliably, and is a fast and advanced approach for environmental γ-spectrometric monitoring. It can be used not only to determination of contents of natural radioactive elements in environments, but also to monitoring nuclear pollution and emergency treatment in nuclear accidents significantly

  19. Conserved peptide fragmentation as a benchmarking tool for mass spectrometers and a discriminating feature for targeted proteomics.

    Science.gov (United States)

    Toprak, Umut H; Gillet, Ludovic C; Maiolica, Alessio; Navarro, Pedro; Leitner, Alexander; Aebersold, Ruedi

    2014-08-01

    Quantifying the similarity of spectra is an important task in various areas of spectroscopy, for example, to identify a compound by comparing sample spectra to those of reference standards. In mass spectrometry based discovery proteomics, spectral comparisons are used to infer the amino acid sequence of peptides. In targeted proteomics by selected reaction monitoring (SRM) or SWATH MS, predetermined sets of fragment ion signals integrated over chromatographic time are used to identify target peptides in complex samples. In both cases, confidence in peptide identification is directly related to the quality of spectral matches. In this study, we used sets of simulated spectra of well-controlled dissimilarity to benchmark different spectral comparison measures and to develop a robust scoring scheme that quantifies the similarity of fragment ion spectra. We applied the normalized spectral contrast angle score to quantify the similarity of spectra to objectively assess fragment ion variability of tandem mass spectrometric datasets, to evaluate portability of peptide fragment ion spectra for targeted mass spectrometry across different types of mass spectrometers and to discriminate target assays from decoys in targeted proteomics. Altogether, this study validates the use of the normalized spectral contrast angle as a sensitive spectral similarity measure for targeted proteomics, and more generally provides a methodology to assess the performance of spectral comparisons and to support the rational selection of the most appropriate similarity measure. The algorithms used in this study are made publicly available as an open source toolset with a graphical user interface. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.

  20. Trace and surface analysis of ceramic layers of solid oxide fuel cells by mass spectrometry.

    Science.gov (United States)

    Becker, J S; Breuer, U; Westheide, J; Saprykin, A I; Holzbrecher, H; Nickel, H; Dietze, H J

    1996-06-01

    For the trace analysis of impurities in thick ceramic layers of a solid oxide fuel cell (SOFC) sensitive solid-state mass spectrometric methods, such as laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and radiofrequency glow discharge mass spectrometry (rf-GDMS) have been developed and used. In order to quantify the analytical results of LA-ICP-MS, the relative sensitivity coefficients of elements in a La(0.6)Sr(0.35)MnO(3) matrix have been determined using synthetic standards. Secondary ion mass spectrometry (SIMS) - as a surface analytical method - has been used to characterize the element distribution and diffusion profiles of matrix elements on the interface of a perovskite/Y-stabilized ZrO(2) layer. The application of different mass spectrometric methods for process control in the preparation of ceramic layers for the SOFC is described.

  1. Determination of hexachlorocyclohexane pesticide residues in wool fat by a combined high-performance liquid chromatographic-gas-liquid chromatographic method

    International Nuclear Information System (INIS)

    Ali, S.L.

    1978-01-01

    Beta- and gamma-hexachlorocyclohexane residues were determined in twelve wool fat samples by using a combined high-performance liquid chromatographic (HPLC)-gas-liquid chromatographic (GLC) method. After extraction and chromatographic clean-up on a silca-gel column, the sample was further purified by HPLC on a reversed-phase C-18 column with methanol as the mobile phase. The final determination was effected by GLC with a 1-mCi nickel-63 electron-capture detector. The analytical method was checked by addition of carbon-14-labelled lindane and measurement of the radioactivity in a liquid scintillation counter. (Auth.)

  2. Liquid chromatographic/electrospray ionization quadrupole/time of flight tandem mass spectrometric study of polyphenolic composition of different Vaccinium berry species and their comparative evaluation.

    Science.gov (United States)

    Ancillotti, Claudia; Ciofi, Lorenzo; Rossini, Daniele; Chiuminatto, Ugo; Stahl-Zeng, Jianru; Orlandini, Serena; Furlanetto, Sandra; Del Bubba, Massimo

    2017-02-01

    Ultra-high-performance liquid chromatography coupled with high-resolution quadrupole-time of flight mass spectrometry with both negative and positive ionization was used for comprehensively investigating the phenolic and polyphenolic compounds in berries from three spontaneous or cultivated Vaccinium species (i.e., Vaccinium myrtillus, Vaccinium uliginosum subsp. gaultherioides, and Vaccinium corymbosum). More than 200 analytes, among phenolic and polyphenolic compounds belonging to the classes of anthocyanins, monomeric and oligomeric flavonols, flavanols, dihydrochalcones, phenolic acids, together with other polyphenolic compounds of mixed structural characteristics, were identified. Some of the polyphenols herein investigated, such as anthocyanidin glucuronides and malvidin-feruloyl-hexosides in V. myrtillus, or anthocyanindin aldopentosides and coumaroyl-hexosides in V. uliginosum subsp. gaultherioides and a large number of proanthocyanidins with high molecular weight in all species, were described for the first time in these berries. Principal component analysis applied on original LC-TOF data, acquired in survey scan mode, successfully discriminated the three Vaccinium berry species investigated, on the basis of their polyphenolic composition, underlying one more time the fundamental role of mass spectrometry for food characterization.

  3. Arsenic speciation in sulfidic waters: reconciling contradictory spectroscopic and chromatographic evidence.

    Science.gov (United States)

    Planer-Friedrich, Britta; Suess, Elke; Scheinost, Andreas C; Wallschläger, Dirk

    2010-12-15

    In recent years, analytical methods have been developed that have demonstrated that soluble arsenic-sulfur species constitute a major fraction of dissolved arsenic in sulfidic waters. However, an intense debate is going on about the exact chemical nature of these compounds, since X-ray absorption spectroscopy (XAS) data generated at higher (mmol/L) concentrations suggest the presence of (oxy)thioarsenites in such waters, while ion chromatographic (IC) and mass spectroscopic data at lower (μmol/L to nmol/L) concentrations indicate the presence of (oxy)thioarsenates. In this contribution, we connect and explain these two apparently different types of results. We show by XAS that thioarsenites are the primary reaction products of arsenite and sulfide in geochemical model experiments in the complete absence of oxygen. However, thioarsenites are extremely unstable toward oxidation, and convert rapidly into thioarsenates when exposed to atmospheric oxygen, e.g., while waiting for analysis on the chromatographic autosampler. This problem can only be eliminated when the entire chromatographic process is conducted inside a glovebox. We also show that thioarsenites are unstable toward sample dilution, which is commonly employed prior to chromatographic analysis when ultrasensitive detectors like ICP-MS are used. This instability has two main reasons: if pH changes during dilution, then equilibria between individual arsenic-sulfur species rearrange rapidly due to their different stability regions within the pH range, and if pH is kept constant during dilution, then this changes the ratio between OH(-) and SH(-) in solution, which in turn shifts the underlying speciation equilibria. This problem is avoided by analyzing samples undiluted. Our studies show that thioarsenites appear as thioarsenates in IC analyses if oxygen is not excluded completely, and as arsenite if samples are diluted in alkaline anoxic medium. This also points out that thioarsenites are necessary

  4. Energy dispersive X-Ray fluorescence spectrometric study of ...

    African Journals Online (AJOL)

    Energy dispersive X-Ray fluorescence spectrometric study of compositional differences in trace elements in dried Moringa oleifera leaves grown in two different agro-ecological locations in Ebonyi State, Nigeria.

  5. Probabilistic peak detection for first-order chromatographic data.

    Science.gov (United States)

    Lopatka, M; Vivó-Truyols, G; Sjerps, M J

    2014-03-19

    We present a novel algorithm for probabilistic peak detection in first-order chromatographic data. Unlike conventional methods that deliver a binary answer pertaining to the expected presence or absence of a chromatographic peak, our method calculates the probability of a point being affected by such a peak. The algorithm makes use of chromatographic information (i.e. the expected width of a single peak and the standard deviation of baseline noise). As prior information of the existence of a peak in a chromatographic run, we make use of the statistical overlap theory. We formulate an exhaustive set of mutually exclusive hypotheses concerning presence or absence of different peak configurations. These models are evaluated by fitting a segment of chromatographic data by least-squares. The evaluation of these competing hypotheses can be performed as a Bayesian inferential task. We outline the potential advantages of adopting this approach for peak detection and provide several examples of both improved performance and increased flexibility afforded by our approach. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Gas Chromatographic-Ion Trap Mass Spectrometric Analysis of Volatile Organic Compounds by Ion-Molecule Reactions Using the Electron-Deficient Reagent Ion CCl{3/+}

    Science.gov (United States)

    Wang, Cheng-Zhong; Su, Yue; Wang, Hao-Yang; Guo, Yin-Long

    2011-10-01

    When using tetrachloromethane as the reagent gas in gas chromatography-ion trap mass spectrometry equipped with hybrid ionization source, the cation CCl{3/+} was generated in high abundance and further gas-phase experiments showed that such an electron-deficient reagent ion CCl{3/+} could undergo interesting ion-molecule reactions with various volatile organic compounds, which not only present some informative gas-phase reactions, but also facilitate qualitative analysis of diverse volatile compounds by providing unique mass spectral data that are characteristic of particular chemical structures. The ion-molecule reactions of the reagent ion CCl{3/+} with different types of compounds were studied, and results showed that such reactions could give rise to structurally diagnostic ions, such as [M + CCl3 - HCl]+ for aromatic hydrocarbons, [M - OH]+ for saturated cyclic ether, ketone, and alcoholic compounds, [M - H]+ ion for monoterpenes, M·+ for sesquiterpenes, [M - CH3CO]+ for esters, as well as the further fragment ions. The mechanisms of ion-molecule reactions of aromatic hydrocarbons, aliphatic ketones and alcoholic compounds with the reagent ion CCl{3/+} were investigated and proposed according to the information provided by MS/MS experiments and theoretical calculations. Then, this method was applied to study volatile organic compounds in Dendranthema indicum var. aromaticum and 20 compounds, including monoterpenes and their oxygen-containing derivatives, aromatic hydrocarbon and sesquiterpenes were identified using such ion-molecule reactions. This study offers a perspective and an alternative tool for the analysis and identification of various volatile compounds.

  7. Isotope dilution/mass spectrometry of serum cholesterol with [3,4-13C]cholesterol: proposed definitive method

    International Nuclear Information System (INIS)

    Pelletier, O.; Wright, L.A.; Breckenridge, W.C.

    1987-01-01

    We describe a new gas-chromatographic/mass-spectrometric (GC/MS) isotope-dilution method for determination of serum cholesterol. The method has been fully optimized and documented to provide the high accuracy and precision expected for a Definitive Method. In the presence of [3,4- 13 C]cholesterol, cholesteryl esters in serum are hydrolyzed under optimum conditions and the entire cholesterol pool is extracted and derivatized to silyl ethers. The cholesterol derivatives are resolved from other sterols by gas-liquid chromatography on a fused silica column, and selected ions characteristic of cholesterol and the [3,4- 13 C]cholesterol are monitored with a GC/MS quandrupole system. We estimated the cholesterol content of samples by bracketing each sample with standards of comparable cholesterol concentration that also contained the [3,4- 13 C]cholesterol. The procedure was highly reproducible (CV less than 0.5%), better accuracy and precision being obtained with [3,4- 13 C]cholesterol than with heptadeuterated cholesterol. Mean values per gram of dry serum for one serum pool assayed by this method and that of the National Bureau of Standards differed by 0.5%. We conclude that the method satisfies the criteria for a Definitive Method

  8. Radiocarbon accelerator mass spectrometry: background and contamination

    International Nuclear Information System (INIS)

    Beukens, R.P.

    1993-01-01

    Since the advent of radiocarbon accelerator mass spectrometry (AMS) many studies have been conducted to understand the background from mass spectrometric processes and the origins of contamination associated with the ion source and sample preparation. By studying the individual contributions a better understanding of these processes has been obtained and it has been demonstrated that it is possible to date samples reliably up to 60 000 BP. (orig.)

  9. Improved Chromatographic Bioavailability Estimations

    National Research Council Canada - National Science Library

    Dorsey, John

    1996-01-01

    .... Since the inception of reversed phase liquid chromatography there have been many attempts to correlate chromatographic retention with bioavailability and the most often used bulk measure, the octanol...

  10. Effects of chromatographic fractions of Euphorbia hirta on the rat ...

    African Journals Online (AJOL)

    The effects of the chromatographic fractions of Euphorbia hirta Linn on the serum biochemical parameters in rats were investigated. The ethanolic extract of this plant was subjected to chromatographic separation using the vacuum liquid chromatographic technique, a modified form of classical column chromatography.

  11. Simultaneous determination of ribavirin and ribavirin base in monkey plasma by high performance liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Li, Wenkui; Luo, Suyi; Li, Shaoyong; Athill, Lawrence; Wu, Amy; Ray, Tapan; Zhou, Wei; Ke, June; Smith, Harold T; Tse, Francis L S

    2007-02-01

    For the first time, a liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the simultaneous determination of ribavirin and rabavirin base was developed and validated over the concentration range of 10-5,000 ng/ml, respectively, using a 0.025 ml monkey plasma sample. Ribavirin, ribavirin base, and the internal standards were extracted from monkey plasma via protein precipitation. After evaporation of the supernatant, the extract was reconstituted with 5% methanol (containing 0.1% formic acid) and injected onto the LC-MS/MS system. Optimum chromatographic separation was achieved on a Waters Atlantis dc18 (150 mm x 2.1mm, 5 microm) column with mobile phase run in gradient with 100% water containing 0.5% formic acid (A) and 90% acetonitrile (containing 0.5% formic acid (B). The flow rate was 0.4-0.6 ml/min with total cycle time of approximately 7.0 min. Post-column addition of acetonitrile (containing 0.1% formic acid) at 0.3 ml/min was used to increase the ionization efficiency in the MS source. The method was validated for sensitivity, linearity, reproducibility, stability and recovery. Lack of adverse matrix effect and carry-over was also demonstrated. The intra-day and inter-day precision and accuracy of the quality control (QC) samples were <9.0% relative standard deviation (R.S.D.) and 10.8% bias for ribavirin, and 10.3% R.S.D. and 11.3% bias for ribavirin base. The current specific, accurate and precise assay is useful in support of the toxicokinetic and pharmacokinetic studies of these compounds.

  12. Gas chromatographic-mass spectrometric characterisation of plant gums in samples from painted works of art.

    Science.gov (United States)

    Bonaduce, Ilaria; Brecoulaki, Hariclia; Colombini, Maria Perla; Lluveras, Anna; Restivo, Vincenzo; Ribechini, Erika

    2007-12-21

    This paper presents an analytical GC-MS procedure to study the chemical composition of plant gums, determining aldoses and uronic acids in one step. The procedure is based on the silylation of aldoses and uronic acids, released from plant gums by microwave assisted hydrolysis, and previously converted into the corresponding diethyl-dithioacetals and diethyl-dithioacetal lactones. Using this method only one peak for each compound is obtained, thus providing simple and highly reproducible chromatograms. The analytical procedure was optimised using reference samples of raw plant gums (arabic, karaya, ghatti, guar, locust bean and tragacanth, cherry, plum and peach gums), commercial watercolours and paint layers prepared according to ancient recipes at the Opificio delle Pietre Dure of Florence (Italy). To identify gum media in samples of unknown composition, a decisional schema for the gum identification and the principal component analysis of the relative sugar percentage contents were employed. The procedure was used to study samples collected from wall paintings from Macedonian tombs (4th-3rd centuries bc) and from the Mycenaean "Palace of Nestor" (13th century bc) in Pylos, Greece. The presence of carbohydrates was ascertained and plant gum binders (fruit and a mixture of tragacanth and fruit tree gums) were identified in some of the samples.

  13. Sensitive measurement of vinorelbine in dog plasma by liquid chromatography-electrospray ionization tandem mass spectrometry utilizing transitions from double-charged precursor ions.

    Science.gov (United States)

    Niwa, Makoto; Kawashiro, Takashi

    2011-04-01

    A sensitive high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for measuring vinorelbine was developed. A 100 µL aliquot of plasma was spiked with deuterium-labeled internal standard and subjected to solid-phase extraction using an Oasis HLB μ-elution plate. Two microliters of the extracted samples was directly injected into LC/MS/MS. Chromatographic separation was achieved on a Capcell Pak C18 UG column (2 × 75 mm) with a gradient elution of methanol (mobile phase B) against 0.05% formic acid in aqueous 10 mm ammonium formate (mobile phase A). The LC flow rate was set to 0.28 mL/min and the gradient (solvent B concentration) was processed from 40 to 90%. In mass spectrometric detection, observation of the reaction from a double-charged precursor ion [M + 2H](2+) (m/z 390) to product ion m/z 122 provided very high sensitivity. The method was validated with a lower limit of detection of 0.2 ng/mL with 0.1 mL of plasma, and the method was used to determine the plasma pharmacokinetics of vinorelbine in dogs. Copyright © 2010 John Wiley & Sons, Ltd.

  14. Rapid, Sensitive and Validated Ultra-Performance Liquid Chromatography/Mass Spectrometric Method for the Determination of Fenofibric Acid and its Application to Human Pharmacokinetic Study

    Directory of Open Access Journals (Sweden)

    Sunil K. Dubey

    2010-01-01

    Full Text Available The first, rapid and sensitive ultra performance liquid chromatography mass spectrometric method for the determination of fenofibric acid, the active metabolite of fenofibrate, a lipid regulating agent, in human EDTA plasma has been developed and validated using fenofibric d6 acid as internal standard and Waters LC-MS/MS. Negative ions of fenofibric acid and fenofibric d6 acid were detected in multiple reaction-monitoring (MRM mode. The method was validated over a concentration range of 0.176 μg/mL to 19.837 μg/mL (r ≥ 0.99. It took only 1.5 minute to analyse a sample. Intra- and inter-run precision of fenofibric acid assay at four concentrations ranged from 0.5% to 4.3% with accuracy varied from 93.1 to 108.1% indicating good precision and accuracy. Analytical recoveries of fenofibric acid and internal standard in plasma were less than 90%. This method was successfully applied for evaluation of pharmacokinetics of fenofibric acid after a single oral dose of 145 mg fenofibrate to 10 Indian healthy volunteers

  15. Simultaneous analysis of amphetamine-type stimulants in plasma by solid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Mariotti, Kristiane de Cássia; Schuh, Roselena S; Ferranti, Priscila; Ortiz, Rafael S; Souza, Daniele Z; Pechansky, Flavio; Froehlich, Pedro E; Limberger, Renata P

    2014-09-01

    Brazil is considered one of the countries with the highest number of amphetamine-type stimulant (ATS) users worldwide, mainly diethylpropion (DIE) and fenproporex (FEN). The use of ATS is mostly linked to diverted prescription stimulants and this misuse is widely associated with (ab)use by drivers. A validated method was developed for the simultaneous analysis of amphetamine (AMP), DIE and FEN in plasma samples employing direct immersion-solid-phase microextraction, and gas chromatographic/mass spectrometric analysis. Trichloroacetic acid 10% was used for plasma deproteinization. In situ derivatization with propylchloroformate was employed. The linear range of the method covered from 5.0 to 100 ng/mL. The detection limits were 1.0 (AMP), 1.5 (DIE) and 2.0 ng/mL (FEN). The accuracy assessment of the control samples was within 85.58-108.33% of the target plasma concentrations. Recoveries ranged from 46.35 to 84.46% and precision was <15% of the value of relative standard deviation. This method is appropriate for screening and confirmation in plasma forensic toxicology analyses of these basic drugs. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Spectrometric assembly for portable installations

    International Nuclear Information System (INIS)

    Kluger, A.; Popescu, C.

    1997-01-01

    The components of the portable spectrometric assembly are: - the detecting probe with Na I(Tl) crystal and air-tight case of industrial type; - a microcomputer; - a unit of analogical processing of the signal from the detecting probe; - a single-channel analyzer with adjustable threshold; - commands and display module; - a source of high voltage; - an electrical supply battery. The device uses the method of gamma photons detection in energetic windows. Through theoretical and experimental studies carried out during the prototype development phase, the superiority of this method has been proved as compared with the installations which make use of the classical principle of photon integral detection. The achieved prototype has a basic program enabling the setting of all working parameters (measuring time, discriminating thresholds, discriminators operating conditions, etc.). Through the included interface RS232 it is possible to transmit the data to a more powerful computer in order to continually process the results. The spectrometric assembly, realized on the basis of micro-computers, can be used in a wide range of applications: measurement of thickness and erosion of walls and tubes, measurement of level in closed containers, of soil density, etc. The adjustment for specific application is performed only through a program modification. (authors)

  17. Identification of chemical warfare agents from vapor samples using a field-portable capillary gas chromatography/membrane-interfaced electron ionization quadrupole mass spectrometry instrument with Tri-Bed concentrator.

    Science.gov (United States)

    Nagashima, Hisayuki; Kondo, Tomohide; Nagoya, Tomoki; Ikeda, Toru; Kurimata, Naoko; Unoke, Shohei; Seto, Yasuo

    2015-08-07

    A field-portable gas chromatograph-mass spectrometer (Hapsite ER system) was evaluated for the detection of chemical warfare agents (CWAs) in the vapor phase. The system consisted of Tri-Bed concentrator gas sampler (trapping time: 3s(-1)min), a nonpolar low thermal-mass capillary gas chromatography column capable of raising temperatures up to 200°C, a hydrophobic membrane-interfaced electron ionization quadrupole mass spectrometer evacuated by a non-evaporative getter pump for data acquisition, and a personal computer for data analysis. Sample vapors containing as little as 22μg sarin (GB), 100μg soman (GD), 210μg tabun (GA), 55μg cyclohexylsarin (GF), 4.8μg sulfur mustard, 390μg nitrogen mustard 1, 140μg of nitrogen mustard 2, 130μg nitrogen mustard 3, 120μg of 2-chloroacetophenone and 990μg of chloropicrin per cubic meter could be confirmed after Tri-Bed micro-concentration (for 1min) and automated AMDIS search within 12min. Using manual deconvolution by background subtraction of neighboring regions on the extracted ion chromatograms, the above-mentioned CWAs could be confirmed at lower concentration levels. The memory effects were also examined and we found that blister agents showed significantly more carry-over than nerve agents. Gasoline vapor was found to interfere with the detection of GB and GD, raising the concentration limits for confirmation in the presence of gasoline by both AMDIS search and manual deconvolution; however, GA and GF were not subject to interference by gasoline. Lewisite 1, and o-chlorobenzylidene malononitrile could also be confirmed by gas chromatography, but it was hard to quantify them. Vapors of phosgene, chlorine, and cyanogen chloride could be confirmed by direct mass spectrometric detection at concentration levels higher than 2, 140, and 10mg/m(3) respectively, by bypassing the micro-concentration trap and gas chromatographic separation. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Practical aspects of trapped ion mass spectrometry, 4 theory and instrumentation

    CERN Document Server

    March, Raymond E

    2010-01-01

    The expansion of the use of ion trapping in different areas of mass spectrometry and different areas of application indicates the value of a single source of information drawing together diverse inputs. This book provides an account of the theory and instrumentation of mass spectrometric applications and an introduction to ion trapping devices.

  19. Peak clustering in two-dimensional gas chromatography with mass spectrometric detection based on theoretical calculation of two-dimensional peak shapes: the 2DAid approach.

    Science.gov (United States)

    van Stee, Leo L P; Brinkman, Udo A Th

    2011-10-28

    A method is presented to facilitate the non-target analysis of data obtained in temperature-programmed comprehensive two-dimensional (2D) gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-ToF-MS). One main difficulty of GC×GC data analysis is that each peak is usually modulated several times and therefore appears as a series of peaks (or peaklets) in the one-dimensionally recorded data. The proposed method, 2DAid, uses basic chromatographic laws to calculate the theoretical shape of a 2D peak (a cluster of peaklets originating from the same analyte) in order to define the area in which the peaklets of each individual compound can be expected to show up. Based on analyte-identity information obtained by means of mass spectral library searching, the individual peaklets are then combined into a single 2D peak. The method is applied, amongst others, to a complex mixture containing 362 analytes. It is demonstrated that the 2D peak shapes can be accurately predicted and that clustering and further processing can reduce the final peak list to a manageable size. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. High-temperature mass spectrometric study of the vaporization processes and thermodynamic properties of melts in the PbO-B2O3-SiO2 system.

    Science.gov (United States)

    Stolyarova, V L; Lopatin, S I; Shilov, A L; Shugurov, S M

    2013-07-15

    The unique properties of the PbO-B2O3-SiO2 system, especially its extensive range of glass-forming compositions, make it valuable for various practical applications. The thermodynamic properties and vaporization of PbO-B2O3-SiO2 melts are not well established so far and the data obtained on these will be useful for optimization of technology and thermodynamic modeling of glasses. High-temperature Knudsen effusion mass spectrometry was used to study vaporization processes and to determine the partial pressures of components of the PbO-B2O3-SiO2 melts. Measurements were performed with a MS-1301 mass spectrometer. Vaporization was carried out using two quartz effusion cells containing the sample under study and pure PbO (reference substance). Ions were produced by electron ionization at an energy of 25 eV. To facilitate interpretation of the mass spectra, the appearance energies of ions were also measured. Pb, PbO and O2 were found to be the main vapor species over the samples studied at 1100 K. The PbO activities as a function of the composition of the system were derived from the measured PbO partial pressures. The B2O3 and SiO2 activities, the Gibbs energy of formation, the excess Gibbs energy of formation and mass losses in the samples studied were calculated. Partial pressures of the vapor species over PbO-B2O3-SiO2 melts were measured at 1100 K in the wide range of compositions using the Knudsen mass spectrometric method. The data enabled the PbO, B2O3, and SiO2 activities in these melts to be derived and provided evidence of their negative deviations from ideal behavior. Copyright © 2013 John Wiley & Sons, Ltd.

  1. Mass-spectrometric exploration of proteome structure and function

    DEFF Research Database (Denmark)

    Aebersold, Ruedi; Mann, Matthias

    2016-01-01

    , the structures and functions of selected proteins have been studied using biochemical and biophysical methods. However, the properties and behaviour of the proteome as an integrated system have largely remained elusive. Powerful mass-spectrometry-based technologies now provide unprecedented insights...

  2. Extending the frontiers of mass spectrometric instrumentation and methods

    Energy Technology Data Exchange (ETDEWEB)

    Schieffer, Gregg Martin [Iowa State Univ., Ames, IA (United States)

    2010-01-01

    The focus of this dissertation is two-fold: developing novel analysis methods using mass spectrometry and the implementation and characterization of a novel ion mobility mass spectrometry instrumentation. The novel mass spectrometry combines ion trap for ion/ion reactions coupled to an ion mobility cell. The long term goal of this instrumentation is to use ion/ion reactions to probe the structure of gas phase biomolecule ions. The three ion source - ion trap - ion mobility - qTOF mass spectrometer (IT - IM - TOF MS) instrument is described. The analysis of the degradation products in coal (Chapter 2) and the imaging plant metabolites (Appendix III) fall under the methods development category. These projects use existing commercial instrumentation (JEOL AccuTOF MS and Thermo Finnigan LCQ IT, respectively) for the mass analysis of the degraded coal products and the plant metabolites, respectively. The coal degradation paper discusses the use of the DART ion source for fast and easy sample analysis. The sample preparation consisted of a simple 50 fold dilution of the soluble coal products in water and placing the liquid in front of the heated gas stream. This is the first time the DART ion source has been used for analysis of coal. Steven Raders under the guidance of John Verkade came up with the coal degradation projects. Raders performed the coal degradation reactions, worked up the products, and sent them to me. Gregg Schieffer developed the method and wrote the paper demonstrating the use of the DART ion source for the fast and easy sample analysis. The plant metabolite imaging project extends the use of colloidal graphite as a sample coating for atmospheric pressure LDI. DC Perdian and I closely worked together to make this project work. Perdian focused on building the LDI setup whereas Schieffer focused on the MSn analysis of the metabolites. Both Perdian and I took the data featured in the paper. Perdian was the primary writer of the paper and used it as a

  3. Detection of radiation-induced hydrocarbons in Camembert irradiated before and after the maturing process-comparison of florisil column chromatography and on-line coupled liquid chromatography-gas chromatography

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Bögl, K.W.; Schreiber, G.A.

    1995-01-01

    The influence of the maturing process on the detection of radiation-induced volatile hydrocarbons in the fat of Camembert has been investigated. Two analytical methods for separation of the hydrocarbon fraction from the lipid were applied: Florisil column chromatography with subsequent gas chromatographic-mass spectrometric (GC-MS) determination as well as on-line coupled liquid chromatography-GC-MS. The maturing process had no influence on the detection of radiation-induced volatiles. Comparable results were achieved with both analytical methods. However, preference is given to the more effective on-line coupled LC-GC method

  4. Sideritis romana L. subsp. purpurea (Tal. ex Benth.) Heywood, a new chemotype from Montenegro.

    Science.gov (United States)

    Garzoli, Stefania; Božović, Mijat; Baldisserotto, Anna; Andreotti, Elisa; Pepi, Federico; Tadić, Vanja; Manfredini, Stefano; Ragno, Rino

    2018-05-01

    A study on essential oil fractions of the Western Balkan endemic Sideritis romana L. subsp. purpurea (Tal. ex Benth.) Heywood collected in Montenegro is reported. The 24-h systematic steam distillation extraction procedure was performed. The gas chromatographic/mass spectrometric (GC/MS) analysis of the fractions showed γ-elemene and spathulenol as two main constituents, revealing a new chemotype of this plant species. Although varying in the content of these two main compounds, which makes the fractions quite different between each other, evaluation of the anti-Candida activity showed the lack of any significant efficacy.

  5. Safety of food contact silicone rubber: Liberation of volatile compounds from soothers and teats

    DEFF Research Database (Denmark)

    Lund, Kirsten H.; Petersen, Jens Højslev

    2002-01-01

    The release of volatile compounds from soothers and teats made from silicone rubber has been investigated. Firstly, measurements of the total release of volatiles were performed according to the method in the draft European standard (CEN). Weight losses of 0.17-0.80% after four hours at 200 degrees......C were observed using gravimetric measurements. One product had a weight loss above the proposed CEN limit of 0.5%. Secondly, the volatile compounds were identified using a thermal desorption/cold trap injector on a gas chromatograph equipped with infrared spectroscopic (IR) and mass spectrometric (MS...

  6. Pharmacokinetic comparison of seven 8-methoxypsoralen brands

    DEFF Research Database (Denmark)

    Menne, T; Andersen, Klaus Ejner; Larsen, E

    1981-01-01

    The pharmacokinetics of seven 8-MOP brands were evaluated in 7 volunteers using an incomplete bloc design. After a single oral dose the 8-MOP plasma level was followed for 3 hours. The plasma concentration was measured with a gas chromatographic - mass spectrometric method, using an isotopic...... dilution technique. The different brands could be divided into three groups. Two gave a high maximum concentration, four a medium, and one a low concentration. The large interbrand variation observed in this study can explain the variations in the results of the treatment and the differing numbers...

  7. Definition of the mitochondrial proteome by measurement of molecular masses of membrane proteins

    Science.gov (United States)

    Carroll, Joe; Fearnley, Ian M.; Walker, John E.

    2006-01-01

    The covalent structure of a protein is incompletely defined by its gene sequence, and mass spectrometric analysis of the intact protein is needed to detect the presence of any posttranslational modifications. Because most membrane proteins are purified in detergents that are incompatible with mass spectrometric ionization techniques, this essential measurement has not been made on many hydrophobic proteins, and so proteomic data are incomplete. We have extracted membrane proteins from bovine mitochondria and detergent-purified NADH:ubiquinone oxidoreductase (complex I) with organic solvents, fractionated the mixtures by hydrophilic interaction chromatography, and measured the molecular masses of the intact membrane proteins, including those of six subunits of complex I that are encoded in mitochondrial DNA. These measurements resolve long-standing uncertainties about the interpretation of the mitochondrial genome, and they contribute significantly to the definition of the covalent composition of complex I. PMID:17060615

  8. Spectrometric properties of crystals for low-energy x-ray diagnostics

    International Nuclear Information System (INIS)

    Barrus, D.m.; Blake, R.L.; Felthauser, H.; Fenimore, E.E.

    1981-01-01

    Quantitative diagnostics of fusion and astrophysical plasmas require knowledge of crystal spectrometric properties. To provide more reliable and versatile diagnostics of plasma conditions, increasingly accurate knowledge of crystal spectrometric properties is becoming necessary. A summary is presented of the following accurately measured parameters for the crystals KAP, RbAP, TlAP, NH 4 AP, NaAP, ADP, and EDDT: the interplanar spacing of atoms; the angle correction for normal and anomalous dispersion that is required for application of the Bragg formula; the thermal expansion coefficient near room temperature for commonly used planes; and the integrated coefficient of reflection

  9. Mass spectrometry of long-lived radionuclides

    International Nuclear Information System (INIS)

    Becker, Johanna Sabine.

    2003-01-01

    The capability of determining element concentrations at the trace and ultratrace level and isotope ratios is a main feature of inorganic mass spectrometry. The precise and accurate determination of isotope ratios of long-lived natural and artificial radionuclides is required, e.g. for their environmental monitoring and health control, for studying radionuclide migration, for age dating, for determining isotope ratios of radiogenic elements in the nuclear industry, for quality assurance and determination of the burn-up of fuel material in a nuclear power plant, for reprocessing plants, nuclear material accounting and radioactive waste control. Inorganic mass spectrometry, especially inductively coupled plasma mass spectrometry (ICP-MS) as the most important inorganic mass spectrometric technique today, possesses excellent sensitivity, precision and good accuracy for isotope ratio measurements and practically no restriction with respect to the ionization potential of the element investigated--therefore, thermal ionization mass spectrometry (TIMS), which has been used as the dominant analytical technique for precise isotope ratio measurements of long-lived radionuclides for many decades, is being replaced increasingly by ICP-MS. In the last few years instrumental progress in improving figures of merit for the determination of isotope ratio measurements of long-lived radionuclides in ICP-MS has been achieved by the application of a multiple ion collector device (MC-ICP-MS) and the introduction of the collision cell interface in order to dissociate disturbing argon-based molecular ions, to reduce the kinetic energy of ions and neutralize the disturbing noble gas ions (e.g. of 129 Xe + for the determination of 129 I). The review describes the state of the art and the progress of different inorganic mass spectrometric techniques such as ICP-MS, laser ablation ICP-MS vs. TIMS, glow discharge mass spectrometry, secondary ion mass spectrometry, resonance ionization mass

  10. Thermogravimetric analysis-mass spectrometry (TG-MS) of selected Chinese palygorskites-Implications for structural water

    International Nuclear Information System (INIS)

    Cheng, Hongfei; Yang, Jing; Frost, Ray L.

    2011-01-01

    Four Chinese palygorskites clay minerals have been analysed by thermogravimetric analysis-mass spectrometry and X-ray diffraction. The structural water of the palygorskite dehydrates in the temperature range of 30-625 o C, as shown in the thermogravimetric analysis and mass spectrometric curves. The mass spectrometric curves combined the differential thermogravimetric curves enable the detailed determination of the main dehydration steps. The results show that the dehydration occurs in four main steps: (a) elimination of interparticle water and partial zeolitic water at below 110 o C, (b) release of the rest part of zeolitic water from the structural layer of palygorskite at about 160 o C, (c) dehydration of one part of bound water at about 340 o C and (d) loss of the rest part of bound water at around 450 o C. The temperatures of dehydration of the palygorskite minerals are found to be influenced by the geological environment and the amount and kind of impurities. The evolved gases in the decomposition process are various because of the different amounts and kind of impurities. It is also found that decarbonization takes place at around 600 o C due to the decomposition of calcite and dolomite impurities in these minerals. It is evident by the mass spectrometric curve that the water is given out from the samples and carbon dioxide originates from the impurity calcite and dolomite.

  11. Study of non-validity of mixture rule near K-absorption edges by X-ray spectrometric technique

    International Nuclear Information System (INIS)

    Sharanabasappa; Chitralekha, A.; Kerur, B.R.; Anilkumar, S.

    2012-01-01

    X-ray spectrometric technique has been described to determine the X-ray mass attenuation coefficient, μ/ρ, of X-rays employing HPGe X-ray detector and radioactive sources. The photon intensity is measured by gating the channel of the spectrometer at FWHM/photo peak. Using the technique the 'best value' values of μ/ρ were obtained for those thicknesses which lie in the transmission (T) range 0.5 ≥ T ≥ 0.02. Total attenuation cross sections for other elements and lead compounds were measured at photon energies from 17 to 88 keV to study the Bragg's additivity law near the absorption edge of the lead. The measured values of mass attenuation coefficient values are compared with theoretical values obtained using Winxcom (programme). This study suggests that measured mass attenuation coefficient values at and near absorption edges differ from the theoretical value by about 17-23%. (author)

  12. Mass spectrometry imaging of surface lipids on intact Drosophila melanogaster flies

    Czech Academy of Sciences Publication Activity Database

    Kaftan, Filip; Vrkoslav, Vladimír; Kynast, P.; Kulkarni, P.; Böcker, S.; Cvačka, Josef; Knaden, M.; Svatoš, Aleš

    2014-01-01

    Roč. 49, č. 3 (2014), s. 223-232 ISSN 1076-5174 R&D Projects: GA ČR GA203/09/0139 Institutional support: RVO:61388963 Keywords : MALDI * laser desorption * mass spectrometric imaging * fruit flies * neutral lipids * sex pheromones * mass shift correction Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.379, year: 2014

  13. Mass spectrometic isotope dilution analysis of Am and Cm in spent fuels

    International Nuclear Information System (INIS)

    Wantschik, M.; Koch, L.; Commission of the European Communities, Karlsruhe; Ganser, B.

    1983-01-01

    Spent nuclear fuels contain Am and Cm in the 10 ppb to 100 ppm range. Because of this low abundance and the necessity of handling small samples of the highly toxic fuel material only a mass-spectrometric isotope dilution analysis can give sufficiently accurate results. Since suitable spikes and/or standards have been lacking, this method has not been applied. Using known masses (+- 0.1%) of Am-241 and Cm-244 metal, Am-243 and Cm-248 spikes were calibrated to an accuracy of better than 0.2%. The standards were reanalysed by chemical titration and several radiometric techniques. The chemical conditioning is based on ionexchange chromatography with alpha-hydroxyisobutyric acid. A sample size of 10 -7 g is sufficient. For the mass-spectrometric measurement 10 -9 g of the elements are required. The accuracy for the determination of the main isotope is 0.5%. (orig./BRB)

  14. Studies on improved integrated membrane-based chromatographic process for bioseparation

    Science.gov (United States)

    Xu, Yanke

    To improve protein separation and purification directly from a fermentation broth, a novel membrane filtration-cum-chromatography device configuration having a relatively impermeable coated zone near the hollow fiber module outlet has been developed. The integrated membrane filtration-cum-chromatography unit packed with chromatographic beads on the shell side of the hollow fiber unit enjoys the advantages of both membrane filtration and chromatography; it allows one to load the chromatographic media directly from the fermentation broth or lysate and separate the adsorbed proteins through the subsequent elution step in a cyclic process. Interfacial polymerization was carried out to coat the bottom section of the hollow fiber membrane while leaving the rest of the hollow fiber membrane unaffected. Myoglobin (Mb), bovine serum albumin (BSA) and a-lactalbumin (a-LA) were used as model proteins in binary mixtures. Separation behaviors of binary protein mixtures were studied in devices using either an ultrafiltration (UF) membrane or a microfiltration (MF) membrane. Experimental results show that the breakthrough time and the protein loading capacities were dramatically improved after coating in both UF and MF modules. For a synthetic yeast fermentation broth feed, the Mb and a-LA elution profiles for the four consecutive cyclic runs were almost superimposable. Due to the lower transmembrane flux in this device plus the periodical washing-elution during the chromatographic separation, fouling was not a problem as it is in conventional microfiltration. A mathematical model describing the hydrodynamic and protein loading behaviors of the integrated device using UF membrane with a coated zone was developed. The simulation results for the breakthrough agree well with the experimental breakthrough curves. The optimal length of the coated zone was obtained from the simulation. A theoretical analysis of the protein mass transfer was performed using a diffusion-convection model

  15. Probabilistic peak detection for first-order chromatographic data

    NARCIS (Netherlands)

    Lopatka, M.; Vivó-Truyols, G.; Sjerps, M.J.

    2014-01-01

    We present a novel algorithm for probabilistic peak detection in first-order chromatographic data. Unlike conventional methods that deliver a binary answer pertaining to the expected presence or absence of a chromatographic peak, our method calculates the probability of a point being affected by

  16. Extraction chromatographic method of uranium(VI) with high molecular mass amine (ALIQUAT - 336)

    International Nuclear Information System (INIS)

    Roy, Uday Sankar; Dutta, Keshab Kumar

    1999-01-01

    A selective method has been developed for reversed phase extraction chromatographic studies of uranium(VI) with Aliquat - 336 (liquid anion exchanger) coated on silica gel as stationary phase. Quantitative extraction of uranium has been achieved in HCl - medium from 1.25(M)-4(M). The effect of different acids with various concentrations stripping agents, flow rate on extraction and elution have been investigated. The exchange capacity of the prepared exchanger has been determined. Uranium(VI) has been separated quantitatively from Th, Ce, Zr, Pb, Ga, Hg, Fe, La, Pr, Nd, Sm and Cr from a binary mixture by controlling the extraction and elution conditions. The separation of U(VI) from ternary and quarternary mixtures of various metal ions has also been achieved. (author)

  17. Functional genomics by mass spectrometry

    DEFF Research Database (Denmark)

    Andersen, Jens S.; Mann, M

    2000-01-01

    Systematic analysis of the function of genes can take place at the oligonucleotide or protein level. The latter has the advantage of being closest to function, since it is proteins that perform most of the reactions necessary for the cell. For most protein based ('proteomic') approaches to gene f...... numbers of intact proteins by mass spectrometry directly. Examples from this laboratory illustrate biological problem solving by modern mass spectrometric techniques. These include the analysis of the structure and function of the nucleolus and the analysis of signaling complexes....

  18. MassSieve: Panning MS/MS peptide data for proteins

    OpenAIRE

    Slotta, Douglas J.; McFarland, Melinda A.; Markey, Sanford P.

    2010-01-01

    We present MassSieve, a Java-based platform for visualization and parsimony analysis of single and comparative LC-MS/MS database search engine results. The success of mass spectrometric peptide sequence assignment algorithms has led to the need for a tool to merge and evaluate the increasing data set sizes that result from LC-MS/MS-based shotgun proteomic experiments. MassSieve supports reports from multiple search engines with differing search characteristics, which can increase peptide sequ...

  19. The theoretical study of full spectrum analysis method for airborne gamma-ray spectrometric data

    International Nuclear Information System (INIS)

    Ni Weichong

    2011-01-01

    Spectra of airborne gamma-ray spectrometry was found to be the synthesis of spectral components of radioelement sources by analyzing the constitution of radioactive sources for airborne gamma-ray spectrometric survey and establishing the models of gamma-ray measurement. The mathematical equation for analysising airborne gamma-ray full spectrometric data can be expressed into matrix and related expansions were developed for the mineral resources exploration, environmental radiation measurement, nuclear emergency monitoring, and so on. Theoretical study showed that the atmospheric radon could be directly computed by airborne gamma-ray spectrometric data with full spectrum analysis without the use of the accessional upward-looking detectors. (authors)

  20. Single-column extraction chromatographic separation of U, Pu, Np and Am

    Energy Technology Data Exchange (ETDEWEB)

    Morgenstern, A.; Apostolidis, C.; Carlos-Marquez, R.; Mayer, K.; Molinet, R. [Commission of the European Communities, Karlsruhe (Germany). European Inst. for Transuranium Elements

    2002-07-01

    A rapid, single-column extraction chromatographic method using commercially available UTEVA resin has been developed for the separation of uranium, plutonium, neptunium and americium. The method yields recoveries superior to 90% and allows direct loading of separated fractions on filaments for subsequent analysis by thermal ionization mass spectrometry. The use of reagents compatible with robotized equipment allows automation of the separation process for routine analysis of nuclear materials. The redox reactions between plutonium, neptunium and hydrogen peroxide involved in the separation process were studied by UV/Vis/NIR absorption spectroscopy. (orig.)

  1. Simultaneous determination of clevidipine and its primary metabolite in dog plasma by liquid chromatography-tandem mass spectrometry: Application to pharmacokinetic study.

    Science.gov (United States)

    Zhou, Ying; Li, Huqun; He, Xiaomeng; Jia, Mengmeng; Ni, Yang; Xu, Mingzhen; Chen, Hui; Li, Weiyong

    2014-11-01

    A simple and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of clevidipine and its primary metabolite H152/81 in dog plasma after protein precipitation with acetonitrile using felodipine as the internal standard (IS). Chromatographic separation was performed on a XB C18 column (2.1mm×50mm, 3.5μm) under isocratic conditions with the mobile phase consisting of acetonitrile and 20mM ammonium acetate buffer (pH 7.0) (40:60, v/v) at the flow rate of 0.3ml/min. The run time was 5.5min. Mass spectrometric analysis was performed on a triple quadrupole mass spectrometer operated in the multiple reaction monitoring (MRM) mode with the transitions of m/z 473.0→338.2 for clevidipine, m/z 356.1→324.0 for H152/81 and m/z 383.9→338.2 for the IS. The method was fully validated in terms of selectivity, linearity, lower limit of quantification (LLOQ), accuracy, precision, stability, matrix effect and recovery over a concentration range of 0.15-200ng/ml for clevidipine and 10-2000ng/ml for H152/81, respectively. The analytical method was applied to support a pharmacokinetic study of simultaneous determination of clevidipine and H152/81 in ten healthy beagle dogs. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Screening and confirmation of steroids and nitroimidazoles in urine, blood, and food matrices: Sample preparation methods and liquid chromatography tandem mass spectrometric separations.

    Science.gov (United States)

    Tölgyesi, Ádám; Barta, Enikő; Simon, Andrea; McDonald, Thomas J; Sharma, Virender K

    2017-10-25

    Veterinary drugs containing synthetic anabolic steroid and nitroimidazole active agents are not allowed for their applications in livestock of the European Union (EU). This paper presents analyses of twelve selected steroids and six nitroimidazole antibiotics at low levels (1.56μg/L-4.95μg/L and 0.17μg/kg-2.14μg/kg, respectively) in body fluids and egg incurred samples. Analyses involved clean-up procedures, high performance liquid chromatography (HPLC) separation, and tandem mass spectrometric screening and confirmatory methods. Target steroids and nitroimidazoles in samples were cleaned by two independent supported liquid extraction and solid phase extraction procedures. Separation of the selected compounds was conducted on Kinetex XB C-18 HPLC column using gradient elution. The screening methods utilised supported liquid extraction that enabled fast and cost effective clean-up. The confirmatory methods were improved by extending the number of matrices and compounds, and by introducing an isotope dilution mass spectrometry for nitroimidazoles. The new methods were validated according to the recommendation of the European Union Reference Laboratories and the performance characteristics evaluated met fully the criteria. The methods were applied to incurred samples in the proficiency tests. The obtained results of Z-scores demonstrated the applicability of developed protocols of the methods to real samples. The confirmatory methods were applied to the national monitoring program and natural contamination of prednisolone could be detected in urine at low concentration in few samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. A rapid novel derivatization of amphetamine and methamphetamine using 2,2,2-trichloroethyl chloroformate for gas chromatography electron ionization and chemical ionization mass spectrometric analysis.

    Science.gov (United States)

    Dasgupta, A; Spies, J

    1998-05-01

    Amphetamine and methamphetamine are commonly abused central nervous system stimulants. We describe a rapid new derivatization of amphetamine and methamphetamine using 2,2,2-trichloroethyl chloroformate for gas chromatography-mass spectrometric analysis. Amphetamine and methamphetamine, along with N-propyl amphetamine (internal standard), were extracted from urine using 1-chlorobutane. The derivatization with 2,2,2-trichloroethyl chloroformate can be achieved at room temperature in 10 minutes. The electron ionization mass spectrum of amphetamine 2,2,2-trichloroethyl carbamate showed two weak molecular ions at m/z 309 and 311, but showed diagnostic strong peaks at m/z 218, 220, and 222. In contrast, chemical ionization of the mass spectrum of amphetamine 2,2,2-trichloroethyl carbamate showed strong (M + 1) ions at m/z 310 and 312 and other strong diagnostic peaks at m/z 274 and 276. The major advantages of this derivative are the presence of a diagnostic cluster of peaks due to the isotopic effect of three chlorine atoms (isotopes 35 and 37) in the derivatized molecule and the relative ease of its preparation. We also observed strong molecular ions for derivatized methamphetamine in the chemical ionization mass spectrum, but the molecular ions were very weak in the electron ionization mass spectrum. We used the scan mode of mass spectrometry in all analyses. When using a urine standard containing 1,000 ng/mL of amphetamine (a 7.4-micromol/L concentration) and methamphetamine (a 6.7-micromol/L concentration), the within-run precisions were 4.8% for amphetamine and 3.6% for methamphetamine. The corresponding between-run precisions were 5.3% for amphetamine and 6.7% for methamphetamine. The assay was linear for amphetamine and methamphetamine concentrations of 250 to 5,000 ng/mL (amphetamine, 1.9-37.0 micromol/L; methamphetamine, 1.7-33.6 micromol/L). The detection limit was 100 ng/mL (amphetamine, 0.74 micromol/L; methamphetamine, 0.67 micromol/L) using the scan mode

  4. Suspect screening of large numbers of emerging contaminants in environmental waters using artificial neural networks for chromatographic retention time prediction and high resolution mass spectrometry data analysis.

    Science.gov (United States)

    Bade, Richard; Bijlsma, Lubertus; Miller, Thomas H; Barron, Leon P; Sancho, Juan Vicente; Hernández, Felix

    2015-12-15

    The recent development of broad-scope high resolution mass spectrometry (HRMS) screening methods has resulted in a much improved capability for new compound identification in environmental samples. However, positive identifications at the ng/L concentration level rely on analytical reference standards for chromatographic retention time (tR) and mass spectral comparisons. Chromatographic tR prediction can play a role in increasing confidence in suspect screening efforts for new compounds in the environment, especially when standards are not available, but reliable methods are lacking. The current work focuses on the development of artificial neural networks (ANNs) for tR prediction in gradient reversed-phase liquid chromatography and applied along with HRMS data to suspect screening of wastewater and environmental surface water samples. Based on a compound tR dataset of >500 compounds, an optimized 4-layer back-propagation multi-layer perceptron model enabled predictions for 85% of all compounds to within 2min of their measured tR for training (n=344) and verification (n=100) datasets. To evaluate the ANN ability for generalization to new data, the model was further tested using 100 randomly selected compounds and revealed 95% prediction accuracy within the 2-minute elution interval. Given the increasing concern on the presence of drug metabolites and other transformation products (TPs) in the aquatic environment, the model was applied along with HRMS data for preliminary identification of pharmaceutically-related compounds in real samples. Examples of compounds where reference standards were subsequently acquired and later confirmed are also presented. To our knowledge, this work presents for the first time, the successful application of an accurate retention time predictor and HRMS data-mining using the largest number of compounds to preliminarily identify new or emerging contaminants in wastewater and surface waters. Copyright © 2015 Elsevier B.V. All rights

  5. Quantitative determination of famotidine in human maternal plasma, umbilical cord plasma and urine using high-performance liquid chromatography - mass spectrometry

    Science.gov (United States)

    Wang, Xiaoming; Rytting, Erik; Abdelrahman, Doaa R.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.

    2013-01-01

    The liquid chromatography with electrospray ionization mass spectrometry for the quantitative determination of famotidine in human urine, maternal and umbilical cord plasma was developed and validated. The plasma samples were alkalized with ammonium hydroxide and extracted twice with ethyl acetate. The extraction recovery of famotidine in maternal and umbilical cord plasma ranged from 53% to 64% and 72% to 79%, respectively. Urine samples were directly diluted with the initial mobile phase then injected into the HPLC system. Chromatographic separation of famotidine was achieved by using a Phenomenex Synergi™ Hydro-RP™ column with a gradient elution of acetonitrile and 10 mM ammonium acetate aqueous solution (pH 8.3, adjusted with ammonium hydroxide). Mass Spectrometric detection of famotidine was set in the positive mode and used a selected ion monitoring method. Carbon-13-labeled famotidine was used as internal standard. The calibration curves were linear (r2> 0.99) in the concentration ranges of 0.631-252 ng/mL for umbilical and maternal plasma samples, and of 0.075-30.0 μg/mL for urine samples. The relative deviation of method was less than 14% for intra- and inter-day assays, and the accuracy ranged between 93% and 110%. The matrix effect of famotidine in human urine, maternal and umbilical cord plasma is less than 17%. PMID:23401067

  6. A low thermal mass fast gas chromatograph and its implementation in fast gas chromatography mass spectrometry with supersonic molecular beams.

    Science.gov (United States)

    Fialkov, Alexander B; Moragn, Mati; Amirav, Aviv

    2011-12-30

    A new type of low thermal mass (LTM) fast gas chromatograph (GC) was designed and operated in combination with gas chromatography mass spectrometry (GC-MS) with supersonic molecular beams (SMB), including GC-MS-MS with SMB, thereby providing a novel combination with unique capabilities. The LTM fast GC is based on a short capillary column inserted inside a stainless steel tube that is resistively heated. It is located and mounted outside the standard GC oven on its available top detector port, while the capillary column is connected as usual to the standard GC injector and supersonic molecular beam interface transfer line. This new type of fast GC-MS with SMB enables less than 1 min full range temperature programming and cooling down analysis cycle time. The operation of the fast GC-MS with SMB was explored and 1 min full analysis cycle time of a mixture of 16 hydrocarbons in the C(10)H(22) up to C(44)H(90) range was achieved. The use of 35 mL/min high column flow rate enabled the elution of C(44)H(90) in less than 45 s while the SMB interface enabled splitless acceptance of this high flow rate and the provision of dominant molecular ions. A novel compound 9-benzylazidanthracene was analyzed for its purity and a synthetic chemistry process was monitored for the optimization of the chemical reaction yield. Biodiesel was analyzed in jet fuel (by both GC-MS and GC-MS-MS) in under 1 min as 5 ppm fatty acid methyl esters. Authentic iprodion and cypermethrin pesticides were analyzed in grapes extract in both full scan mode and fast GC-MS-MS mode in under 1 min cycle time and explosive mixture including TATP, TNT and RDX was analyzed in under 1 min combined with exhibiting dominant molecular ion for TATP. Fast GC-MS with SMB is based on trading GC separation for speed of analysis while enhancing the separation power of the MS via the enhancement of the molecular ion in the electron ionization of cold molecules in the SMB. This paper further discusses several features of

  7. Mass Spectrometric Investigation of Silicon Extremely Enriched in (28)Si: From (28)SiF4 (Gas Phase IRMS) to (28)Si Crystals (MC-ICP-MS).

    Science.gov (United States)

    Pramann, Axel; Rienitz, Olaf

    2016-06-07

    A new generation of silicon crystals even further enriched in (28)Si (x((28)Si) > 0.999 98 mol/mol), recently produced by companies and institutes in Russia within the framework of a project initiated by PTB, were investigated with respect to their isotopic composition and molar mass M(Si). A modified isotope dilution mass spectrometric (IDMS) method treating the silicon as the matrix containing a so-called virtual element (VE) existing of the isotopes (29)Si and (30)Si solely and high resolution multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) were applied in combination. This method succeeds also when examining the new materials holding merely trace amounts of (29)Si (x((29)Si) ≈ 5 × 10(-6) mol/mol) and (30)Si (x((30)Si) ≈ 7 × 10(-7) mol/mol) extremely difficult to detect with lowest uncertainty. However, there is a need for validating the enrichment in (28)Si already in the precursor material of the final crystals, silicon tetrafluoride (SiF4) gas prior to crystal production. For that purpose, the isotopic composition of selected SiF4 samples was determined using a multicollector magnetic sector field gas-phase isotope ratio mass spectrometer. Contaminations of SiF4 by natural silicon due to storing and during the isotope ratio mass spectrometry (IRMS) measurements were observed and quantified. The respective MC-ICP-MS measurements of the corresponding crystal samples show-in contrast-several advantages compared to gas phase IRMS. M(Si) of the new crystals were determined to some extent with uncertainties urel(M) < 1 × 10(-9). This study presents a clear dependence of the uncertainty urel(M(Si)) on the degree of enrichment in (28)Si. This leads to a reduction of urel(M(Si)) during the past decade by almost 3 orders of magnitude and thus further reduces the uncertainty of the Avogadro constant NA which is one of the preconditions for the redefinition of the SI unit kilogram.

  8. Nuclear Forensics: Measurements of Uranium Oxides Using Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS)

    Science.gov (United States)

    2010-03-01

    Isotope Ratio Analysis of Actinides , Fission Products, and Geolocators by High- efficiency Multi-collector Thermal Ionization Mass Spectrometry...Information, 1999. Hou, Xiaolin, and Per Roos. “ Critical Comparison of radiometric and Mass Spectrometric Methods for the Determination of...NUCLEAR FORENSICS: MEASUREMENTS OF URANIUM OXIDES USING TIME-OF-FLIGHT SECONDARY ION MASS

  9. Tandem mass spectrometric analysis of cyclophosphamide, ifosfamide and their metabolites.

    Science.gov (United States)

    Liu, Zhongfa; Chan, Kenneth K; Wang, Jeffrey J

    2005-01-01

    A detailed multi-stage (MSn) fragmentation study of cyclophosphamide (CP), ifosfamide (IF) and their major metabolites, using an ion-trap mass spectrometer and a Q-TOF mass spectrometer, was performed with the aid of specifically deuterium-labeled analogs. The analytes showed good responses in positive-ion electrospray mass spectrometry as [MH]+ ions. Tandem mass spectra revealed a wealth of structurally specific ions, allowing characterization of the fragmentation pathways of these analytes. The major fragmentation pathways of the protonated CP and IF are elimination of ethylene from C5 and C6 of 1,3,2-oxazaphosphorine-2-oxide via a McLafferty rearrangement, and cleavage of the P-N bond. However, their activated 4-OOH and 4-OH metabolites primarily underwent hydrogen peroxide elimination and dehydration, respectively, followed by fragmentation pathways similar to those of CP and IF. These results should prove useful in structural elucidation of future analogs of CP and IF, and/or of their metabolites. Copyright (c) 2005 John Wiley & Sons, Ltd.

  10. Review of application of mass spectrometry for analyses of anterior eye proteome

    Institute of Scientific and Technical Information of China (English)

    Sherif; Elsobky; Ashley; M; Crane; Michael; Margolis; Teresia; A; Carreon; Sanjoy; K; Bhattacharya

    2014-01-01

    Proteins have important functional roles in the body, which can be altered in disease states. The eye is a complex organ rich in proteins; in particular, the anterior eye is very sophisticated in function and is most commonly involved in ophthalmic diseases. Proteomics, the large scale study of proteins, has greatly impacted our knowledge and understanding of gene function in the post-genomic period. The most significant breakthrough in proteomics has been mass spectrometric identification of proteins, which extends analysis far beyond the mere display of proteins that classical techniques provide. Mass spectrometry functions as a "mass analyzer" which simplifies the identification and quantification of proteins extracted from biological tissue. Mass spectrometric analysis of the anterior eye proteome provides a differential display for protein comparison of normal and diseased tissue. In this article wepresent the key proteomic findings in the recent literature related to the cornea, aqueous humor, trabecular meshwork, iris, ciliary body and lens. Through this we identified unique proteins specific to diseases related to the anterior eye.

  11. Analysis of bacterial vaginosis-related amines in vaginal fluid by gas chromatography and mass spectrometry.

    Science.gov (United States)

    Wolrath, H; Forsum, U; Larsson, P G; Borén, H

    2001-11-01

    The presence of various amines in vaginal fluid from women with malodorous vaginal discharge has been reported before. The investigations have used several techniques to identify the amines. However, an optimized quantification, together with a sensitive analysis method in connection with a diagnostic procedure for vaginal discharge, including the syndrome of bacterial vaginosis, as defined by the accepted "gold standard," has not been done before. We now report a sensitive gas chromatographic and mass spectrometric method for identifying the amines isobutylamine, phenethylamine, putrescine, cadaverine, and tyramine in vaginal fluid. We used weighted samples of vaginal fluid to obtain a correct quantification. In addition, a proper diagnosis was obtained using Gram-stained smears of the vaginal fluid that were Nugent scored according to the method of Nugent et al. (R. P. Nugent et al., J. Clin. Microbiol., 29:297-301, 1991). We found that putrescine, cadaverine, and tyramine occurred in high concentrations in vaginal fluid from 24 women with Nugent scores between 7 and 10. These amines either were not found or were found only in very low concentrations in vaginal fluid from women with Nugent scores of 0 to 3. There is a strong correlation between bacterial vaginosis and the presence of putrescine, cadaverine, and tyramine in high concentrations in vaginal fluid.

  12. Effect of chromatographic separation on ASP system interface tension and the countermeasures

    Directory of Open Access Journals (Sweden)

    Jiawei REN

    2016-06-01

    Full Text Available Because of the existing chromatographic separation phenomenon, ASP flooding changes original nature of the system. Therefore, in laboratory ultra-low interfacial tension ASP system is preferred for sand packs flow experiment to research on the effect of chromatographic separation on ASP system interface tension. The two parameters of "breakthrough time" and "output difference" are used to describe the degree of chromatographic separation, and the produced fluid interfacial tensions at the outlet end at 120 min is measured. The research shows that there exists chromatographic separation between three chemicals of ASP system, with first polymer breakthrough and finally surfactant breakthrough; there is most serious chromatographic separation between surfactant and polymer, while minimum chromatographic separation between alkali and polymer; chromatographic separation makes ASP interfacial tension increase from 10-3 magnitude to 10-2 magnitude, affecting flooding effect of ASP system. Thus, reducing the loss of surfactant in the formation will be the main measure to reduce the degree of chromatographic separation. Using sophorolipid as sacrificial agent to replace part of the surfactant injected into formation before ASP system can effectively reduce the impact of chromatography separation and more effectively improve the ultimate recovery ratio.

  13. Comprehensive two-dimensional liquid chromatographic analysis of poloxamers.

    Science.gov (United States)

    Malik, Muhammad Imran; Lee, Sanghoon; Chang, Taihyun

    2016-04-15

    Poloxamers are low molar mass triblock copolymers of poly(ethylene oxide) (PEO) and poly(propylene oxide) (PPO), having number of applications as non-ionic surfactants. Comprehensive one and two-dimensional liquid chromatographic (LC) analysis of these materials is proposed in this study. The separation of oligomers of both types (PEO and PPO) is demonstrated for several commercial poloxamers. This is accomplished at the critical conditions for one of the block while interaction for the other block. Reversed phase LC at CAP of PEO allowed for oligomeric separation of triblock copolymers with regard to PPO block whereas normal phase LC at CAP of PPO renders oligomeric separation with respect to PEO block. The oligomeric separation with regard to PEO and PPO are coupled online (comprehensive 2D-LC) to reveal two-dimensional contour plots by unconventional 2D IC×IC (interaction chromatography) coupling. The study provides chemical composition mapping of both PEO and PPO, equivalent to combined molar mass and chemical composition mapping for several commercial poloxamers. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Mass spectrometry allows direct identification of proteins in large genomes

    DEFF Research Database (Denmark)

    Küster, B; Mortensen, Peter V.; Andersen, Jens S.

    2001-01-01

    Proteome projects seek to provide systematic functional analysis of the genes uncovered by genome sequencing initiatives. Mass spectrometric protein identification is a key requirement in these studies but to date, database searching tools rely on the availability of protein sequences derived fro...

  15. Precision of glucose measurements in control sera by isotope dilution/mass spectrometry: proposed definitive method compared with a reference method

    International Nuclear Information System (INIS)

    Pelletier, O.; Arratoon, C.

    1987-01-01

    This improved isotope-dilution gas chromatographic/mass spectrometric (GC/MS) method, in which [ 13 C]glucose is the internal standard, meets the requirements of a Definitive Method. In a first study with five reconstituted lyophilized sera, a nested analysis of variance of GC/MS values indicated considerable among-vial variation. The CV for 32 measurements per serum ranged from 0.5 to 0.9%. However, concentration and uncertainty values (mmol/L per gram of serum) assigned to one serum by the NBS Definitive Method (7.56 +/- 0.28) were practically identical to those obtained with the proposed method (7.57 +/- 0.20). In the second study, we used twice more [ 13 C]glucose diluent to assay four serum pools and two lyophilized sera. The CV ranged from 0.26 to 0.5% for the serum pools and from 0.28 to 0.59% for the lyophilized sera. In comparison, results by the hexokinase/glucose-6-phosphate dehydrogenase reference method agreed within acceptable limits with those by the Definitive Method but tended to be slightly higher (up to 3%) for lyophilized serum samples or slightly lower (up to 2.5%) for serum pools

  16. Fast and Efficient XML Data Access for Next-Generation Mass Spectrometry.

    Science.gov (United States)

    Röst, Hannes L; Schmitt, Uwe; Aebersold, Ruedi; Malmström, Lars

    2015-01-01

    In mass spectrometry-based proteomics, XML formats such as mzML and mzXML provide an open and standardized way to store and exchange the raw data (spectra and chromatograms) of mass spectrometric experiments. These file formats are being used by a multitude of open-source and cross-platform tools which allow the proteomics community to access algorithms in a vendor-independent fashion and perform transparent and reproducible data analysis. Recent improvements in mass spectrometry instrumentation have increased the data size produced in a single LC-MS/MS measurement and put substantial strain on open-source tools, particularly those that are not equipped to deal with XML data files that reach dozens of gigabytes in size. Here we present a fast and versatile parsing library for mass spectrometric XML formats available in C++ and Python, based on the mature OpenMS software framework. Our library implements an API for obtaining spectra and chromatograms under memory constraints using random access or sequential access functions, allowing users to process datasets that are much larger than system memory. For fast access to the raw data structures, small XML files can also be completely loaded into memory. In addition, we have improved the parsing speed of the core mzML module by over 4-fold (compared to OpenMS 1.11), making our library suitable for a wide variety of algorithms that need fast access to dozens of gigabytes of raw mass spectrometric data. Our C++ and Python implementations are available for the Linux, Mac, and Windows operating systems. All proposed modifications to the OpenMS code have been merged into the OpenMS mainline codebase and are available to the community at https://github.com/OpenMS/OpenMS.

  17. Fast and Efficient XML Data Access for Next-Generation Mass Spectrometry.

    Directory of Open Access Journals (Sweden)

    Hannes L Röst

    Full Text Available In mass spectrometry-based proteomics, XML formats such as mzML and mzXML provide an open and standardized way to store and exchange the raw data (spectra and chromatograms of mass spectrometric experiments. These file formats are being used by a multitude of open-source and cross-platform tools which allow the proteomics community to access algorithms in a vendor-independent fashion and perform transparent and reproducible data analysis. Recent improvements in mass spectrometry instrumentation have increased the data size produced in a single LC-MS/MS measurement and put substantial strain on open-source tools, particularly those that are not equipped to deal with XML data files that reach dozens of gigabytes in size.Here we present a fast and versatile parsing library for mass spectrometric XML formats available in C++ and Python, based on the mature OpenMS software framework. Our library implements an API for obtaining spectra and chromatograms under memory constraints using random access or sequential access functions, allowing users to process datasets that are much larger than system memory. For fast access to the raw data structures, small XML files can also be completely loaded into memory. In addition, we have improved the parsing speed of the core mzML module by over 4-fold (compared to OpenMS 1.11, making our library suitable for a wide variety of algorithms that need fast access to dozens of gigabytes of raw mass spectrometric data.Our C++ and Python implementations are available for the Linux, Mac, and Windows operating systems. All proposed modifications to the OpenMS code have been merged into the OpenMS mainline codebase and are available to the community at https://github.com/OpenMS/OpenMS.

  18. Matrix-assisted laser desorption/ionization mass spectrometric imaging for the rapid segmental analysis of methamphetamine in a single hair using umbelliferone as a matrix.

    Science.gov (United States)

    Wang, Hang; Wang, Ying

    2017-07-04

    Segmental hair analysis offers a longer period for retrospective drug detection than blood or urine. Hair is a keratinous fiber and is strongly hydrophobic. The embedding of drugs in hydrophobic hair at low concentrations makes it difficult for extraction and detection with matrix-assisted laser desorption/ionization (MALDI) coupled with mass spectrometric imaging (MSI). In this study, a single scalp hair was longitudinally cut with a cryostat section to a length of 4 mm and fixed onto a stainless steel MALDI plate. Umbelliferone was used as a new hydrophobic matrix to enrich and assist the ionization efficiency of methamphetamine in the hair sample. MALDI-Fourier transform ion cyclotron resonance (FTICR)-MS profiling and imaging were performed for direct detection and mapping of methamphetamine on the longitudinal sections of the single hair sample in positive ion mode. Using MALDI-MSI, the distribution of methamphetamine was observed throughout five longitudinally sectioned hair samples from a drug abuser. The changes of methamphetamine were also semi-quantified by comparing the ratios of methamphetamine/internal standard (I.S). This method improves the detection sensitivity of target drugs embedded in a hair matrix for imaging with mass spectrometry. The method could provide a detection level of methamphetamine down to a nanogram per milligram incorporated into hair. The results were also compared with the conventional high performance liquid chromatography -tandem mass spectrometry (HPLC-MS/MS) method. Changes in the imaging results over time by the MSI method showed good semi-quantitative correlation to the results from the HPLC-MS/MS method. This study provides a powerful tool for drug abuse control and forensic medicine analysis in a narrow time frame, and a reduction in the sample amount required. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. [Latest development in mass spectrometry for clinical application].

    Science.gov (United States)

    Takino, Masahiko

    2013-09-01

    Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has seen enormous growth in special clinical chemistry laboratories. It significantly increases the analytic potential in clinical chemistry, especially in the field of low molecular weight biomarker analysis. This review summarizes the state of the art in mass spectrometry and related techniques for clinical application with a main focus on recent developments in LC-MS. Current trends in ionization techniques, automated online sample preparation techniques coupled with LC-MS, and ion mobility spectrometry are discussed. Emerging mass spectrometric approaches complementary to LC-MS are discussed as well.

  20. Mass spectrometric studies of stable isotope-labelled carboxylic acid derivatives

    International Nuclear Information System (INIS)

    Andersson, B.Aa.; Dinger, F.; Dinh-Nguyen, N.

    1975-01-01

    Low resolution mass spectra of deuterium and carbon-13 labelled fatty acid pyrrolidides are discussed. The simple fragmentation pattern of pyrrolidides makes them superior to other derivatives, regarding location of isotopes. Deuteriation of ethylenic fatty acid pyrrolidides therefore seems to be an improved method to locate carbon-carbon double bonds by mass spectrometry. (author)

  1. Evaluation of pesticide adsorption in gas chromatographic injector and column

    Directory of Open Access Journals (Sweden)

    Gevany Paulino de Pinho

    2012-01-01

    Full Text Available Components in complex matrices can cause variations in chromatographic response during analysis of pesticides by gas chromatography. These variations are related to the competition between analytes and matrix components for adsorption sites in the chromatographic system. The capacity of the pesticides chlorpyrifos and deltamethrin to be adsorbed in the injector and chromatographic column was evaluated by constructing three isotherms and changing the column heating rate to 10 and 30 ºC min-1. By using ANCOVA to compare the slope of calibration graphs, results showed that the higher the injector temperature (310 ºC the lower the pesticide adsorption. Also, deltamethrin influenced the adsorption of chlorpyrifos on the column chromatographic.

  2. Simultaneous determination of water-soluble vitamins in SRM 1849 Infant/Adult Nutritional Formula powder by liquid chromatography-isotope dilution mass spectrometry.

    Science.gov (United States)

    Goldschmidt, Robert J; Wolf, Wayne R

    2010-05-01

    Assessing dietary intake of vitamins from all sources, including foods, dietary supplements, and fortified foods, would be aided considerably by having analytical methodologies that are capable of simultaneous determination of several vitamins. Vitamins naturally present in foods may occur in different chemical forms, with levels ranging over several orders of magnitude. Vitamins in dietary supplements and fortified foods, however, are typically added in a single chemical form, and matrix issues are usually not as complex. These sources should thus be relatively amenable to approaches that aim for simultaneous determination of multiple vitamins. Our recent work has focused on development of liquid chromatography (LC)-UV/fluorescence and LC-tandem mass spectrometry methods for the simultaneous determination of water-soluble vitamins (thiamine, niacin, pyridoxine, pantothenic acid, folic acid, biotin, and riboflavin) in dietary supplement tablets and fortified foods, such as formula powders and breakfast cereals. As part of the validation of our methods and collaboration in characterization of a new NIST SRM 1849 Infant/Adult Nutritional Formula powder, we report data on SRM 1849 using isotope dilution mass spectrometric methods. Use of available NIST Standard Reference Materials(R) as test matrices in our method development and validation gives a benchmark for future application of these methods. We compare three chromatographic approaches and provide data on stability of vitamin standard solutions for LC-based multiple vitamin determinations.

  3. Electronic equipment for spectrometric data processing

    International Nuclear Information System (INIS)

    Antonov, L.J.; Trenev, A.M.; Todorova, E.I.; Dimitrov, V.D.

    1978-01-01

    Electronic equipment carrying out logical operations and a full set of the arithmetic operations was developed for spectrometric data processing. The flowsheet of the computing part of the device, made on the basis of a specialized integral circuit, is given. The device includes input registers, multiplexor, matrix commutator, arithmetic unit and indication unit. The equipment is rated to carry out calculations according to comparatively complex formulae in several seconds

  4. Carbon nanotubes as solid-phase extraction sorbents prior to atomic spectrometric determination of metal species: A review

    International Nuclear Information System (INIS)

    Herrero Latorre, C.; Álvarez Méndez, J.; Barciela García, J.; García Martín, S.; Peña Crecente, R.M.

    2012-01-01

    Highlights: ► The use of CNTs as sorbent for metal species in solid phase extraction has been described. ► Physical and chemical strategies for functionalization of carbon nanotubes have been discussed. ► Published analytical methods concerning solid phase extraction and atomic spectrometric determination have been reviewed. - Abstract: New materials have significant impact on the development of new methods and instrumentation for chemical analysis. From the discovery of carbon nanotubes in 1991, single and multi-walled carbon nanotubes – due to their high adsorption and desorption capacities – have been employed as sorption substrates in solid-phase extraction for the preconcentration of metal species from diverse matrices. Looking for successive improvements in sensitivity and selectivity, in the past few years, carbon nanotubes have been utilized as sorbents for solid phase extraction in three different ways: like as-grown, oxidized and functionalized nanotubes. In the present paper, an overview of the recent trends in the use of carbon nanotubes for solid phase extraction of metal species in environmental, biological and food samples is presented. The determination procedures involved the adsorption of metals on the nanotube surface, their quantitative desorption and subsequent measurement by means of atomic spectrometric techniques such as flame atomic absorption spectrometry, electrothermal atomic absorption spectrometry or inductively coupled plasma atomic emission spectrometry/mass spectrometry, among others. Synthesis, purification and types of carbon nanotubes, as well as the diverse chemical and physical strategies for their functionalization are described. Based on 140 references, the performance and general properties of the applications of solid phase extraction based on carbon nanotubes for metal species atomic spectrometric determination are discussed.

  5. Carbon nanotubes as solid-phase extraction sorbents prior to atomic spectrometric determination of metal species: A review

    Energy Technology Data Exchange (ETDEWEB)

    Herrero Latorre, C., E-mail: carlos.herrero@usc.es [Universidad de Santiago de Compostela, Dpto. Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Alfonso X el Sabio s/n, 27002 Lugo (Spain); Alvarez Mendez, J.; Barciela Garcia, J.; Garcia Martin, S.; Pena Crecente, R.M. [Universidad de Santiago de Compostela, Dpto. Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Alfonso X el Sabio s/n, 27002 Lugo (Spain)

    2012-10-24

    Highlights: Black-Right-Pointing-Pointer The use of CNTs as sorbent for metal species in solid phase extraction has been described. Black-Right-Pointing-Pointer Physical and chemical strategies for functionalization of carbon nanotubes have been discussed. Black-Right-Pointing-Pointer Published analytical methods concerning solid phase extraction and atomic spectrometric determination have been reviewed. - Abstract: New materials have significant impact on the development of new methods and instrumentation for chemical analysis. From the discovery of carbon nanotubes in 1991, single and multi-walled carbon nanotubes - due to their high adsorption and desorption capacities - have been employed as sorption substrates in solid-phase extraction for the preconcentration of metal species from diverse matrices. Looking for successive improvements in sensitivity and selectivity, in the past few years, carbon nanotubes have been utilized as sorbents for solid phase extraction in three different ways: like as-grown, oxidized and functionalized nanotubes. In the present paper, an overview of the recent trends in the use of carbon nanotubes for solid phase extraction of metal species in environmental, biological and food samples is presented. The determination procedures involved the adsorption of metals on the nanotube surface, their quantitative desorption and subsequent measurement by means of atomic spectrometric techniques such as flame atomic absorption spectrometry, electrothermal atomic absorption spectrometry or inductively coupled plasma atomic emission spectrometry/mass spectrometry, among others. Synthesis, purification and types of carbon nanotubes, as well as the diverse chemical and physical strategies for their functionalization are described. Based on 140 references, the performance and general properties of the applications of solid phase extraction based on carbon nanotubes for metal species atomic spectrometric determination are discussed.

  6. Ionization mechanisms in capillary supercritical fluid chromatography-chemical ionization mass spectrometry

    NARCIS (Netherlands)

    Houben, R.J.; Leclercq, P.A.; Cramers, C.A.M.G.

    1991-01-01

    Ionization mechanisms have been studied for supercritical fluid chromatography (SFC) with mass spectrometric (MS) detection. One of the problems associated with SFC-MS is the interference of mobile phase constituents in the ionization process, which complicates the interpretation of the resulting

  7. Analysis of Nitro-aromatic and Nitramine Explosives by Atmospheric Pressure Chemical Ionization / High Performance Liquid Chromatography / Mass Spectrometry / Mass Spectrometry

    International Nuclear Information System (INIS)

    Hicks, B.J.; Han, W.; Robben, J.R.

    2009-01-01

    This procedure is capable of separating and quantifying twenty-nine high explosives and internal surrogates with a single injection. After the initial preparation step, the sample is introduced to the high performance liquid chromatograph for target separation, ionized by atmospheric pressure chemical ionization and the explosives of interest are isolated / quantified by mass spectrometry / mass spectrometry. Concentrations of the target explosives are measured relative to the response of both internal and external standard concentrations. A C-18 reverse phase high performance liquid chromatograph column is used for separation. Ionization is performed using both positive and negative atmospheric pressure chemical ionization resulting in a molecular ion with little fragmentation. These ions are isolated at the first quadrupole of the mass spectrometer, dissociated by collision with argon in the collision cell and the resulting daughter ions are isolated at the second quadrupole. These daughter ions then reach the detector where they are quantified. To date this procedure represents the most thorough high performance liquid chromatography / mass spectrometry / mass spectrometry explosives analysis available in the environmental chemistry market. (authors)

  8. Determination of plutonium isotopes (238Pu, 239Pu, 240Pu, 241Pu) in environmental samples using radiochemical separation combined with radiometric and mass spectrometric measurements.

    Science.gov (United States)

    Xu, Yihong; Qiao, Jixin; Hou, Xiaolin; Pan, Shaoming; Roos, Per

    2014-02-01

    This paper reports an analytical method for the determination of plutonium isotopes ((238)Pu, (239)Pu, (240)Pu, (241)Pu) in environmental samples using anion exchange chromatography in combination with extraction chromatography for chemical separation of Pu. Both radiometric methods (liquid scintillation counting and alpha spectrometry) and inductively coupled plasma mass spectrometry (ICP-MS) were applied for the measurement of plutonium isotopes. The decontamination factors for uranium were significantly improved up to 7.5 × 10(5) for 20 g soil compared to the level reported in the literature, this is critical for the measurement of plutonium isotopes using mass spectrometric technique. Although the chemical yield of Pu in the entire procedure is about 55%, the analytical results of IAEA soil 6 and IAEA-367 in this work are in a good agreement with the values reported in the literature or reference values, revealing that the developed method for plutonium determination in environmental samples is reliable. The measurement results of (239+240)Pu by alpha spectrometry agreed very well with the sum of (239)Pu and (240)Pu measured by ICP-MS. ICP-MS can not only measure (239)Pu and (240)Pu separately but also (241)Pu. However, it is impossible to measure (238)Pu using ICP-MS in environmental samples even a decontamination factor as high as 10(6) for uranium was obtained by chemical separation. © 2013 Elsevier B.V. All rights reserved.

  9. Gas chromatographic isolation technique for compound-specific radiocarbon analysis

    International Nuclear Information System (INIS)

    Uchida, M.; Kumamoto, Y.; Shibata, Y.; Yoneda, M.; Morita, M.; Kawamura, K.

    2002-01-01

    Full text: We present here a gas chromatographic isolation technique for the compound-specific radiocarbon analysis of biomarkers from the marine sediments. The biomarkers of fatty acids, hydrocarbon and sterols were isolated with enough amount for radiocarbon analysis using a preparative capillary gas chromatograph (PCGC) system. The PCGC systems used here is composed of an HP 6890 GC with FID, a cooled injection system (CIS, Gerstel, Germany), a zero-dead-volume effluent splitter, and a cryogenic preparative collection device (PFC, Gerstel). For AMS analysis, we need to separate and recover sufficient quantity of target individual compounds (>50 μgC). Yields of target compounds from C 14 n-alkanes to C 40 to C 30 n-alkanes and approximately that of 80% for higher molecular weights compounds more than C 30 n-alkanes. Compound specific radiocarbon analysis of organic compounds, as well as compound-specific stable isotope analysis, provide valuable information on the origins and carbon cycling in marine system. Above PCGC conditions, we applied compound-specific radiocarbon analysis to the marine sediments from western north Pacific, which showed the possibility of a useful chronology tool for estimating the age of sediment using organic matter in paleoceanographic study, in the area where enough amounts of planktonic foraminifera for radiocarbon analysis by accelerator mass spectrometry (AMS) are difficult to obtain due to dissolution of calcium carbonate. (author)

  10. Spectrometric determination of ammonium-nitrogen with quinol in ...

    African Journals Online (AJOL)

    Quinol is proposed as a reagent for the spectrometric determination of ammonium-nitrogen (NH4+-N) in aqueous medium. Quinol forms a pink complex with ammonium salt in aqueous medium. Hydrogen peroxide is needed for colour accentuation. The quinol/ammonium charge transfer complex has absorption maximum ...

  11. Spectrometric properties and radiation damage of BGO crystals

    Science.gov (United States)

    Kim, Gen C.; Gasanov, Eldar M.

    1997-07-01

    Spectrometric properties, such as light output, energy resolution BGO crystals before and after (superscript 60)Co gamma-ray (dose 10(superscript 4) - 10(superscript 6) R) and neutron irradiation (fluence 10(superscript 14) cm(superscript -2)) are investigated. Condition for degradation of spectrometric properties and their recovering after irradiation are studied. The energy spectrum of the photons emitted from BGO crystals irradiated with neutron fluence contains the long living background peak which is caused by self-irradiation with radioactive isotopes produced in the crystals. The defect production was studied in crystals under the high dose gamma-irradiation with (superscript 60)Co isotope. It was found that after doses above 10(superscript 8) R the color center at 365 nm and doses higher than 10(superscript 9) R a wide absorption band in the region of 300 - 350 nm occur. Comparison of these results with those of reactor irradiation has shown that under the high dose gamma-irradiation the structure defect production takes place.

  12. Gas-Chromatographic Determination Of Water In Freon PCA

    Science.gov (United States)

    Melton, Donald M.

    1994-01-01

    Gas-chromatographic apparatus measures small concentrations of water in specimens of Freon PCA. Testing by use of apparatus faster and provides greater protection against accidental contamination of specimens by water in testing environment. Automated for unattended operation. Also used to measure water contents of materials, other than Freon PCA. Innovation extended to development of purgeable sampling accessory for gas chromatographs.

  13. Mass spectrometry of submicrogram quantities of lead and cadmium

    International Nuclear Information System (INIS)

    Moraes, Noemia M.P. de; Kakazu, M.H.; Iyer, S.S.

    1980-01-01

    Isotope analyses of submicrogram quantities of lead and cadmium are carried out by single filament solid source mass spectrometry. Thermionic emission of Pb and Cd is enhanced using silica gel as an emitter. Details of the chemical and mass spectrometric techniques are described. The low blank levels are maintained by extra purification of the reagents. The applications of isotope ratios of Pb and Cd in environmental sciences and geochemistry are discussed. (Author) [pt

  14. Identification of Polish cochineal (Porphyrophora polonica L.) in historical textiles by high-performance liquid chromatography coupled with spectrophotometric and tandem mass spectrometric detection.

    Science.gov (United States)

    Lech, Katarzyna; Jarosz, Maciej

    2016-05-01

    The present work reports a method for identification of Polish cochineal (Porphyrophora polonica L.) in historical fabrics by the use of high-performance liquid chromatography coupled with diode array and tandem mass spectrometric detection with electrospray ionization (HPLC-DAD-ESI MS/MS). This hyphened technique allows detection and identification of 16 new minor colorants present in the discussed scale insect (including two previously observed by Wouters and Verhecken (Ann Soc Entomol Fr. 1989;25:393-410), but specified only as compounds of unknown structures) that do not occur (e.g., in American cochineal). The MS/MS experiments, complemented with UV-VIS data, enable identification of mono- and di-, C- and O-hexosides of kermesic and flavokermesic acids or their derivatives. The present paper introduces a fingerprint of color compounds present in Polish cochineal and defines them, particularly pp6 (ppI, O-hexoside of flavokermesic acid), as its markers allow distinguishing of Polish-cochineal reds from the American ones. Usefulness of the selected set of markers for identification of Polish cochineal has been demonstrated in the examination of textiles from the collection of the National Museum in Warsaw using the multiple reaction monitoring (MRM) method, originally elaborated on the basis of this study.

  15. Chromatographic fingerprinting through chemometric techniques for herbal slimming pills: A way of adulterant identification.

    Science.gov (United States)

    Shekari, Nafiseh; Vosough, Maryam; Tabar Heidar, Kourosh

    2018-05-01

    In the current study, gas chromatography-mass spectrometry (GC-MS) fingerprinting of herbal slimming pills assisted by chemometric methods has been presented. Deconvolution of two-way chromatographic signals of nine herbal slimming pills into pure chromatographic and spectral patterns was performed. The peak clusters were resolved using multivariate curve resolution-alternating least squares (MCR-ALS) by employing appropriate constraints. It was revealed that more useful chemical information about the composition of the slimming pills can be obtained by employing sophisticated GC-MS method coupled with proper chemometric tools yielding the extended number of identified constituents. The thorough fingerprinting of the complex mixtures proved the presence of some toxic or carcinogen components, such as toluene, furfural, furfuryl alcohol, styrene, itaconic anhydride, citraconic anhydride, trimethyl phosphate, phenol, pyrocatechol, p-propenylanisole and pyrogallol. In addition, some samples were shown to be adulterated with undeclared ingredients, including stimulants, anorexiant and laxatives such as phenolphthalein, amfepramone, caffeine and sibutramine. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Analysis of Biologic Samples for Morphine and Morphine-Related Compounds by Gas Chromatographic-Mass Spectrometric Methods

    Science.gov (United States)

    1976-04-01

    formation is not necessary if the purpose is to detect diacetylinorphine or methadone but most screening procedures have as their purpose the detection of a...in the following way. Morphine hydrochloride (10.7 mg, 0.1 mM) was dissolved in 600 V1 of dimethylsulfoxide (distilled over calcium hydride). To .i...and the residue was dissolved in ethanol. Normor- phine hydrochloride was precipitated upon addition of n-pentane. Storage of the mixture (freezer

  17. Predicting protein aggregation during storage in lyophilized solids using solid state amide hydrogen/deuterium exchange with mass spectrometric analysis (ssHDX-MS).

    Science.gov (United States)

    Moorthy, Balakrishnan S; Schultz, Steven G; Kim, Sherry G; Topp, Elizabeth M

    2014-06-02

    Solid state amide hydrogen/deuterium exchange with mass spectrometric analysis (ssHDX-MS) was used to assess the conformation of myoglobin (Mb) in lyophilized formulations, and the results correlated with the extent of aggregation during storage. Mb was colyophilized with sucrose (1:1 or 1:8 w/w), mannitol (1:1 w/w), or NaCl (1:1 w/w) or in the absence of excipients. Immediately after lyophilization, samples of each formulation were analyzed by ssHDX-MS and Fourier transform infrared spectroscopy (FTIR) to assess Mb conformation, and by dynamic light scattering (DLS) and size exclusion chromatography (SEC) to determine the extent of aggregation. The remaining samples were then placed on stability at 25 °C and 60% RH or 40 °C and 75% RH for up to 1 year, withdrawn at intervals, and analyzed for aggregate content by SEC and DLS. In ssHDX-MS of samples immediately after lyophilization (t = 0), Mb was less deuterated in solids containing sucrose (1:1 and 1:8 w/w) than in those containing mannitol (1:1 w/w), NaCl (1:1 w/w), or Mb alone. Deuterium uptake kinetics and peptide mass envelopes also indicated greater Mb structural perturbation in mannitol, NaCl, or Mb-alone samples at t = 0. The extent of deuterium incorporation and kinetic parameters related to rapidly and slowly exchanging amide pools (Nfast, Nslow), measured at t = 0, were highly correlated with the extent of aggregation on storage as measured by SEC. In contrast, the extent of aggregation was weakly correlated with FTIR band intensity and peak position measured at t = 0. The results support the use of ssHDX-MS as a formulation screening tool in developing lyophilized protein drug products.

  18. Direct measurement of burn up monitor by Pulsed Laser Deposition (PLD) followed by Isotopic Dilution Mass Spectrometry

    International Nuclear Information System (INIS)

    Sajimol, R.; Manoravi, P.; NaIini, S.; Balasubramanian, R.; Joseph, M.

    2012-01-01

    Burn-up measurement is an important aspect in the assessment of fuel performance especially for experimental nuclear fuels. Conventional mass spectrometric technique offer the best accuracy for determination of burn-up but they suffer from the labour intensive and time consuming chemical separation procedures followed by mass spectrometric analysis. Our laboratory has reported a potential laser mass spectrometric technique with advantages of (i) direct and fast measurement of ion intensities of selected rare earth element and residual heavy element atoms to deduce burn up and (ii) adaptability to remote handling of radioactive samples. Direct quantification of burn up monitor element in fuel in the form of pellet as well as liquid was probed by pulsed laser deposition followed by Isotopic Dilution Mass Spectrometric technique (IDMS). The procedure involving laser ablation of heavy element (namely U and Pu) and fission product (Nd, La etc) from a simulated spent fuel matrix followed by isotopic dilution mass spectrometry using thermal ionization mass spectrometry (TIMS) has been presently attempted to arrive at the rare earth element to heavy element ratio to deduce burn up using the methodology described in our earlier work. The details of IDMS technique has been reviewed by Heumann et al. Accurately weighed amounts of major rare earth fission products such as Nd, La, Ce and Sm in solution form were mixed with known quantity of uranium solution (all the weights are corresponding to their fission yields and the residual heavy element atoms after a given burn up) and mixed together to attain uniformity. The solution is then dried and resulting powder was pelletized and sintered. Subsequently, the pellet was ablated with pulsed laser (8 ns, 532 nm, Nd-YAG) and the plume was deposited on a glass plate. This deposit was dissolved in minimum amount of nitric acid. A known volume of the solution was mixed with spike (for e.g., 150 Nd/ 142 Nd, 233 U/ 238 U in this study

  19. An analytical method for cyclosporine using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Kanduru, Srividya V; Somayaji, Vishwa; Lavasanifar, Afsaneh; Brocks, Dion R

    2010-02-01

    A liquid chromatographic mass spectrometric (LC-MS) assay has been developed for cyclosporine A (CyA) in rat plasma using amiodarone as internal standard (IS). Rat plasma (100 microL) containing drug and IS were extracted using liquid-liquid extraction with 4 mL of 95:5 ether:methanol. After evaporation of the organic layer the residue was reconstituted with 500 microL of water. Then the aqueous layer was transferred to LC-MS sample vials. A 10 microL volume was injected. The analysis was performed on a C(8) column 3.5 microm (2.1 x 50 mm) heated to 60 degrees C with a mobile phase consisting of acetonitrile:methanol:0.2% NH(4)OH (60:20:20) at an isocratic flow-rate of 0.2 mL/min. The ions used for quantitation of CyA and IS were m/z 1202.8 and 645.9, with retention times of 3.35 and 4.72 min, respectively. Linear relationships (r(2) > 0.99) were achieved between plasma or blood concentration and peak height ratios (drug:IS) over the concentration range 50-5000 ng/mL. The CV% and mean error were <19%. Based on validation data, the lower limit of quantification for the assay was 50 ng/mL. The reported assay method displayed high measures of linearity, sensitivity, reliability and precision, allowing its applicability in pharmacokinetic studies in rat. (c) 2009 John Wiley & Sons, Ltd.

  20. Seasonal variations of bisphenol A in the Danube River by the municipality of Novi Sad, Serbia

    Directory of Open Access Journals (Sweden)

    Milanović Maja

    2016-01-01

    Full Text Available Seasonal variations of bisphenol A (BPA were investigated in the Danube along the Novi Sad bank, Serbia using solid-phase extraction followed by gas chromatographic mass spectrometric method. The obtained results confirmed the presence of BPA above the limit of quantification (6 ng/L in 22 out of 32 water samples at all eight sampling sites. Тhe BPA concentration varied from 1 for autumn, spring and summer. The high potential risk which is attributed to the elevated summer concentrations is probably the result of the increased human activates and weather conditions. [Projekat Ministarstva nauke Republike Srbije, br. III46009