WorldWideScience

Sample records for chinese slimming capsules

  1. Chinese Patent Medicine Tongxinluo Capsule for Hypertension: A Systematic Review of Randomised Controlled Trials

    OpenAIRE

    Jie Wang; Xingjiang Xiong; Wei Liu

    2014-01-01

    Background. This study was intended to evaluate the efficacy and safety of Tongxinluo capsule for hypertension. Search Strategy. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library, The PubMed, EMBASE, Chinese Bio-Medical Literature Database (CBM), Chinese National Knowledge Infrastructure (CNKI), Chinese Scientific Journal Database, and Wan-fang Data started from the first of database to October 28, 2013. No language restriction was applied. We in...

  2. Slim SUSY

    Energy Technology Data Exchange (ETDEWEB)

    Arganda, Ernesto, E-mail: ernesto.arganda@fisica.unlp.edu.ar [IFLP, CONICET – Dpto. de Física, Universidad Nacional de La Plata, C.C. 67, 1900 La Plata (Argentina); Lorenzo Diaz-Cruz, J., E-mail: jldiaz@fcfm.buap.mx [Facultad de Ciencias Físico-Matemáticas, Benemérita Universidad Autónoma de Puebla, Puebla (Mexico); Szynkman, Alejandro, E-mail: szynkman@fisica.unlp.edu.ar [IFLP, CONICET – Dpto. de Física, Universidad Nacional de La Plata, C.C. 67, 1900 La Plata (Argentina)

    2013-05-13

    The new SM-like Higgs boson discovered recently at the LHC, with mass m{sub h}≃125 GeV, as well as the direct LHC bounds on the mass of superpartners, which are entering into the TeV range, suggest that the minimal surviving supersymmetric extension of the SM (MSSM), should be characterized by a heavy SUSY-breaking scale. Several variants of the MSSM have been proposed to account for this result, which vary according to the accepted degree of fine-tuning. We propose an alternative scenario here, Slim SUSY, which contains sfermions with multi-TeV masses and gauginos/higgsinos near the EW scale, but it includes the heavy MSSM Higgs bosons (H{sup 0}, A{sup 0}, H{sup ±}) near the EW scale too. We discuss first the formulation and constraints of the Slim SUSY scenario, and then identify distinctive heavy Higgs signals that could be searched at the LHC, within scenarios with the minimal number of superpartners with masses near the EW scale.

  3. Chinese Patent Medicine Tongxinluo Capsule for Hypertension: A Systematic Review of Randomised Controlled Trials

    Directory of Open Access Journals (Sweden)

    Jie Wang

    2014-01-01

    Full Text Available Background. This study was intended to evaluate the efficacy and safety of Tongxinluo capsule for hypertension. Search Strategy. We searched the Cochrane Central Register of Controlled Trials (CENTRAL in the Cochrane Library, The PubMed, EMBASE, Chinese Bio-Medical Literature Database (CBM, Chinese National Knowledge Infrastructure (CNKI, Chinese Scientific Journal Database, and Wan-fang Data started from the first of database to October 28, 2013. No language restriction was applied. We included randomized clinical trials testing Tongxinluo capsule against western medicine, Tongxinluo capsule versus placebo, and Tongxinluo capsule combined with western medicine versus western medicine. Study selection, data extraction, quality assessment, and data analyses were conducted according to the Cochrane standards. Results. 25 trials with 1958 participants were included. The methodological quality of the included trials was evaluated as generally low. The blood pressure (BP lowering effect of Tongxinluo capsule plus western medicine was significantly higher than that of western medicine (systolic blood pressure (SBP: −3.87, −5.32 to −2.41, P<0.00001; and diastolic blood pressure (DBP: −2.72, −4.19 to −1.24, P=0.0003. The BP also decreased significantly from baseline with Tongxinluo capsule than placebo (SBP: −9.40, −10.90 to −7.90, P<0.00001; and DBP: −11.80, −12.40 to −11.20, P<0.00001 or western medicine (SBP: −3.90, −4.93 to −2.87, P<0.00001; and DBP: −3.70, −3.83 to −3.57, P<0.00001. 12 trials reported adverse events without details. Conclusions. There is some but weak evidence about the effectiveness of TXL in treating patients with hypertension.

  4. Chinese patent medicine tongxinluo capsule for hypertension: a systematic review of randomised controlled trials.

    Science.gov (United States)

    Wang, Jie; Xiong, Xingjiang; Liu, Wei

    2014-01-01

    This study was intended to evaluate the efficacy and safety of Tongxinluo capsule for hypertension. Search Strategy. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library, The PubMed, EMBASE, Chinese Bio-Medical Literature Database (CBM), Chinese National Knowledge Infrastructure (CNKI), Chinese Scientific Journal Database, and Wan-fang Data started from the first of database to October 28, 2013. No language restriction was applied. We included randomized clinical trials testing Tongxinluo capsule against western medicine, Tongxinluo capsule versus placebo, and Tongxinluo capsule combined with western medicine versus western medicine. Study selection, data extraction, quality assessment, and data analyses were conducted according to the Cochrane standards. Results. 25 trials with 1958 participants were included. The methodological quality of the included trials was evaluated as generally low. The blood pressure (BP) lowering effect of Tongxinluo capsule plus western medicine was significantly higher than that of western medicine (systolic blood pressure (SBP): -3.87, -5.32 to -2.41, P < 0.00001; and diastolic blood pressure (DBP): -2.72, -4.19 to -1.24, P = 0.0003). The BP also decreased significantly from baseline with Tongxinluo capsule than placebo (SBP: -9.40, -10.90 to -7.90, P < 0.00001; and DBP: -11.80, -12.40 to -11.20, P < 0.00001) or western medicine (SBP: -3.90, -4.93 to -2.87, P < 0.00001; and DBP: -3.70, -3.83 to -3.57, P < 0.00001). 12 trials reported adverse events without details. Conclusions. There is some but weak evidence about the effectiveness of TXL in treating patients with hypertension. PMID:24693319

  5. Effect of Chinese Herbal Medicine Combined with Acitretin Capsule in Treating Psoriasis of Blood-Heat Syndrome Type

    Institute of Scientific and Technical Information of China (English)

    张立新; 白彦萍; 宋佩华; 尤立平; 杨顶权

    2009-01-01

    Objective:To observe the clinical curative effect of Chinese herbal medicine combined with acitretin capsule in treating psoriasis of blood-heat syndrome(P-BH).Methods:Eighty patients of P-BH were randomly assigned to two groups,39 in Group A and 41 in Group B.Both was treated with Chinese herbal medicines for clearing heat,cooling blood and removing toxic substance,and acitretin capsule was given to Group A additionally,with 8 weeks as one therapeutic course.The clinical curative effect was compared bet...

  6. Chinese medicinal formula Fufang Xueshuantong capsule could inhibit the activity of angiotensin converting enzyme

    Science.gov (United States)

    Sheng, Shujing; Wang, Yonggang; Long, Chaofeng; Su, Weiwei; Rong, Xia

    2014-01-01

    Fufang Xueshuantong (FXST) capsule, a Chinese medicinal formula composed of four herbals – Panax notoginseng, Radix Astragali, Radix Salvia Miltiorrhizae and Radix Scrophulariaceae, has been used to treat cardiovascular diseases for many years, but the pharmacological mechanisms underlying its effects has not been clarified. This study investigates if a connection between FXST and angiotensin converting enzyme (ACE) might be an explanation for its pharmacological effects. ACE inhibition assay was performed on FXST capsule, 50% ethanol extracts from the four herbals and three selected saponins most abundant in P. notoginseng (Ginsenoside Rg1, Ginsenoside Rb1 and Notoginsenoside R1) using a biochemical test. Reversed-phase high-performance liquid chromatography of liberated hippuric acid from the ACE assay was conducted to determine the inhibitory effect. As a result, FXST and extracts from P. notoginseng showed a significant and dose-dependent inhibition on ACE activity with the IC50 values of 115 μg/ml and 179 μg/ml, respectively. But extracts from the other three herbals and the three selected saponins had no significant effect on ACE inhibition. Compared to other reported plant extracts, FXST could be considered as an effective ACE inhibitor. The inhibition of ACE activity supports the traditional use of FXST on blood circulation and the inhibitory property of FXST is mainly caused by P. notoginseng. PMID:26019516

  7. Sau San Tong: A Paragon of the Slimming and Beauty Business

    OpenAIRE

    Susan Tai

    2006-01-01

    Sau San Tong Holdings was established in July 2000 and initially sold Chinese herbal slimming medicines. In 2001, it moved into the full-body slimming business. Within three years, the company had transformed itself into a Growth Enterprise Market listed company, operating four slimming centres in Hong Kong and two in Shanghai. The major shareholder, Shirley Cheung Yuk Shan (the former TV artist) controlled over 50% of the company. Shirley Cheung, who had strong marketing skills and a special...

  8. Measurement of the volume of internal capsule in healthy Chinese adults of the Han nationality on the high-resolution MRI

    International Nuclear Information System (INIS)

    Objective: To explore the normal range of the volume of internal capsules in Chinese adults of the Han nationality and its relationship with age, body habitus, and craniocerebral volume. Methods: One thousand healthy volunteers (age range =18 to 80 years) were divided into 5 groups according to their age; Group A (18 to 30 years old), group B (31 to 40 years), group C (41 to 50 years), group D (51 to 60 years), and group E (61 to 80 years). Each group consisted of 100 males and 100 females. MR imaging was performed in all of the volunteers using T1 weighted three-dimensional magnetization prepared rapid acquisition gradient echo sequence. After three dimension data reconstruction, the volumes of bilateral internal capsules were manually measured. The volumes of bilateral internal capsules were compared by paired sample t test. The internal capsule volumes were compared between male and female by independent sample t test, and the differences among 5 age groups were compared by one-way ANOVA. The relationship between the volumes of internal capsule and age, body habitus or cerebral volume were analyzed using bivariate correlation. Results: The left and right internal capsule volumes were (2809 ± 393) and (2677 ± 343 ) mm3 respectively. The left internal capsule volumes were significantly larger than that of right (t=12.078, P<0.05). The left and right side of internal capsule volumes in male were (2863 ± 396) and (2744 ±358) mm3 respectively, and (2754 ±385) and (2609 ±314) mm3 in female. The left and right internal capsule volumes were larger in males than in female (t=1.982, 2.851; P<0.05). The left internal capsule volume of the 5 age groups were (3273 ± 361), (2943 ± 299), (2777 ± 255), (2607 ± 199), (2444 ±213) mm3, and the right were (2993 ± 361), (2814 ± 270), (2682 ± 239), (2543 ± 219), (2351 ±210) mm3. There were significant differences among 5 age groups between left and right internal capsule volume (F=55.244, 34.493; P<0.05). There was

  9. Feasibility study of resist slimming for SIT

    Science.gov (United States)

    Saulnier, Nicole; Koay, Chiew-seng; Colburn, Matthew; Hetzer, David; Cicoria, Michael; Ludwicki, Jonathan

    2013-03-01

    Wet chemical slimming of resist can enable a resist mandrel for sidewall-image transfer (SIT) by decreasing the mandrel width and smoothing the mandrel sidewalls. This would reduce the cost of the SIT process. Several key metrics are used to compare the traditional etched mandrel and the slimmed resist mandrel, including: process window, critical dimension uniformity, and defectivity. New resists are shown to have larger process windows after slimming than an etched mandrel process while maintaining comparable critical dimension uniformity. The major challenge to the resist mandrel is the profile post-slim.

  10. Relative bioequivalence evaluation of two oral atomoxetine hydrochloride capsules: a single dose, randomized, open-label, 2-period crossover study in healthy Chinese volunteers under fasting conditions.

    Science.gov (United States)

    Shang, D-W; Guo, W; Zhou, F-C; Wang, X-P; Li, A-N; Zhang, L; Li, W-B; Lu, W; Wang, C-Y

    2013-11-01

    To evaluate the bioequivalence of a new formulation of atomoxetine hydrochloride (CAS 82248-59-7) capsules (test) and an available branded capsules (reference) after administration of a single 40 mg dose, randomized, open-label, 2-period crossover study was conducted in 22 healthy male Chinese subjects with a 1-week wash-out period. This study was designed for/the Honglin Pharmaceutical Co. Ltd and contracted to be done by the Beijing Anding Hospital in order to satisfy Chinese regulatory requirements to allow marketing of this generic product and performed according to the criteria of SFDA. Blood samples were collected before and 0.25, 0.5, 1, 1.5, 2, 3, 4, 6, 9, 12, 16 and 24 h after drug administration. Plasma concentrations were determined by high-performance liquid chromatography (HPLC) with UV detection. A non-compartmental method was used to calculate the pharmacokinetic parameters and evaluate bioequivalence of the 2 formulations. The 90% confidence interval (CI) of the ratios (test/reference) of atomoxetine for AUC0-24, AUC0-∞ and Cmax were 100.9% (93.6-108.8%), 103.1% (95.1-111.7%) and 105.2% (92.8-119.4%), respectively, which fell within the interval of 80-125% and 75-133%. No clinically significant changes or abnormalities were noted in laboratory data and vital signs. From these results it can be concluded that the test formulation of atomoxetine capsules met the regulatory criterion for bioequivalence to the reference formulation. PMID:23812961

  11. SLIM for Agile Mission Lifecycle Management Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The principal technical innovation is SLIM (Systems LIfecycle Management), a software environment for integrated model-based systems engineering, combining SysML...

  12. Capsule endoscopy

    DEFF Research Database (Denmark)

    Skovsen, Anders Peter; Burcharth, Jakob; Burgdorf, Stefan Kobbelgaard

    2013-01-01

    of capsule retention, especially in patients with known or suspected Crohn's disease, due to the propensity of Crohn's disease to form stenosis of the bowel. In cases where a stenosis is suspected, it is warranted to perform a patency capsule swallow before subjecting the patient to a capsule...

  13. Xuesaitong Soft Capsule (Chinese Patent Medicine) for the Treatment of Unstable Angina Pectoris: A Meta-Analysis and Systematic Review

    OpenAIRE

    Xiaochen Yang; Xingjiang Xiong; Heran Wang; Guoyan Yang; Jie Wang

    2013-01-01

    Objective. To provide a systematic review to evaluate the effectiveness and safety of Xuesaitong soft capsule (XST) in treating unstable angina (UA). Methods. An extensive search of 6 medical databases was performed up to August 2013. Randomized controlled trials (RCTs) involving XST alone or combined with conventional drugs versus conventional drugs were included. A meta-analysis of reduction of angina symptoms and electrocardiogram (ECG) improvement was performed to evaluate the effects of ...

  14. Quantitative phase imaging of Breast cancer cell based on SLIM

    Science.gov (United States)

    Wu, Huaqin; Li, Zhifang; Li, Hui; Wu, Shulian

    2016-02-01

    We illustrated a novel optical microscopy technique to observe cell dynamics via spatial light interference microscopy (SLIM). SLIM combines Zemike's phase contrast microscopy and Gabor's holography. When the light passes through the transparent specimens, it could render high contrast intensity and record the phase information from the object. We reconstructed the Breast cancer cell phase image by SLIM and the reconstruction algorithm. Our investigation showed that SLIM has the ability to achieve the quantitative phase imaging (QPI).

  15. Xuesaitong Soft Capsule (Chinese Patent Medicine for the Treatment of Unstable Angina Pectoris: A Meta-Analysis and Systematic Review

    Directory of Open Access Journals (Sweden)

    Xiaochen Yang

    2013-01-01

    Full Text Available Objective. To provide a systematic review to evaluate the effectiveness and safety of Xuesaitong soft capsule (XST in treating unstable angina (UA. Methods. An extensive search of 6 medical databases was performed up to August 2013. Randomized controlled trials (RCTs involving XST alone or combined with conventional drugs versus conventional drugs were included. A meta-analysis of reduction of angina symptoms and electrocardiogram (ECG improvement was performed to evaluate the effects of XST on UA. Results. After researching, a total of 6 RCTs with 716 participants were included. Our review showed that XST combined with conventional drugs had significant effect on relieving angina symptoms (RR: 1.14 [1.07,1.22]; P=0.0001 and improving ECG (RR: 1.26 [1.12,1.42]; P=0.0001 compared with conventional drugs alone. Conclusions. XST appears to have beneficial effects on improvement of ECG, reduction of angina symptoms, and decreasing the frequency and duration of angina attack in participants with UA. However, the findings should be interpreted with caution due to the poor methodological quality of the included trials.

  16. Xuesaitong soft capsule (chinese patent medicine) for the treatment of unstable angina pectoris: a meta-analysis and systematic review.

    Science.gov (United States)

    Yang, Xiaochen; Xiong, Xingjiang; Wang, Heran; Yang, Guoyan; Wang, Jie

    2013-01-01

    Objective. To provide a systematic review to evaluate the effectiveness and safety of Xuesaitong soft capsule (XST) in treating unstable angina (UA). Methods. An extensive search of 6 medical databases was performed up to August 2013. Randomized controlled trials (RCTs) involving XST alone or combined with conventional drugs versus conventional drugs were included. A meta-analysis of reduction of angina symptoms and electrocardiogram (ECG) improvement was performed to evaluate the effects of XST on UA. Results. After researching, a total of 6 RCTs with 716 participants were included. Our review showed that XST combined with conventional drugs had significant effect on relieving angina symptoms (RR: 1.14 [1.07, 1.22]; P = 0.0001) and improving ECG (RR: 1.26 [1.12, 1.42]; P = 0.0001) compared with conventional drugs alone. Conclusions. XST appears to have beneficial effects on improvement of ECG, reduction of angina symptoms, and decreasing the frequency and duration of angina attack in participants with UA. However, the findings should be interpreted with caution due to the poor methodological quality of the included trials. PMID:24489594

  17. Qualitative and Quantitative Analysis of the Major Constituents in Chinese Medical Preparation Lianhua-Qingwen Capsule by UPLC-DAD-QTOF-MS

    Directory of Open Access Journals (Sweden)

    Weina Jia

    2015-01-01

    Full Text Available Lianhua-Qingwen capsule (LQC is a commonly used Chinese medical preparation to treat viral influenza and especially played a very important role in the fight against severe acute respiratory syndrome (SARS in 2002-2003 in China. In this paper, a rapid ultraperformance liquid chromatography coupled with diode-array detector and quadrupole time-of-flight mass spectrometry (UPLC-DAD-QTOF-MS method was established for qualitative and quantitative analysis of the major constituents of LQC. A total of 61 compounds including flavonoids, phenylpropanoids, anthraquinones, triterpenoids, iridoids, and other types of compounds were unambiguously or tentatively identified by comparing the retention times and accurate mass measurement with reference compounds or literature data. Among them, twelve representative compounds were further quantified as chemical markers in quantitative analysis, including salidroside, chlorogenic acid, forsythoside E, cryptochlorogenic acid, amygdalin, sweroside, hyperin, rutin, forsythoside A, phillyrin, rhein, and glycyrrhizic acid. The UPLC-DAD method was evaluated with linearity, limit of detection (LOD, limit of quantification (LOQ, precision, stability, repeatability, and recovery tests. The results showed that the developed quantitative method was linear, sensitive, and precise for the quality control of LQC.

  18. Global Slim Accretion Disk Solutions Revisited

    OpenAIRE

    Jiao, Cheng-Liang; Xue, Li; Gu, Wei-Min; Lu, Ju-Fu

    2008-01-01

    We show that there exists a maximal possible accretion rate, beyond which global slim disk solutions cannot be constructed because in the vertical direction the gravitational force would be unable to balance the pressure force to gather the accreted matter. The principle for this restriction is the same as that for the Eddington luminosity and the corresponding critical accretion rate, which were derived for spherical accretion by considering the same force balance in the radial direction. If...

  19. The observational appearance of slim accretion disks

    CERN Document Server

    Szuszkiewicz, E; Abramowicz, M A; Szuszkiewicz, Ewa; Malkan, Matthew A; Abramowicz, Marek Artur

    1995-01-01

    We reexamine the hypothesis that the optical/UV/soft X-ray continuum of Active Galactic Nuclei is thermal emission from an accretion disk. Previous studies have shown that fitting the spectra with the standard, optically thick and geometrically thin accretion disk models often led to luminosities which contradict the basic assumptions adopted in the standard model. There is no known reason why the accretion rates in AGN should not be larger than the thin disk limit. In fact, more general, slim accretion disk models are self-consistent even for moderately super-Eddington luminosities. We calculate here spectra from a set of thin and slim, optically thick accretion disks. We discuss the differences between the thin and slim disk models, stressing the implications of these differences for the interpretation of the observed properties of AGN. We found that the spectra can be fitted not only by models with a high mass and a low accretion rate (as in the case of thin disk fitting) but also by models with a low mass...

  20. The Functional Study of a Chinese Herbal Compounded Antidepressant Medicine--Jie Yu Chu Fan Capsule on Chronic Unpredictable Mild Stress Mouse Model.

    Directory of Open Access Journals (Sweden)

    Lingling Ding

    Full Text Available Jie Yu Chu Fan capsule (JYCF is a new compounded Chinese herbal medicine for the treatment of depression. The present study was designed to explore the antidepressant effects and the possible mechanisms of JYCF by using chronic unpredictable mild stress (CUMS mouse model and comparing results to that of fluoxetine. Behavioral tests including an open field test, sucrose preference test and forced swim test were performed to evaluate the antidepressant effects of JYCF. The concentrations of monoamine neurotransmitters and metabolic products including norepinephrine (NE, 5-hydroxytryptamine (5-HT, dopamine (DA, 5-hydroxyindoleacetic acid (5-HIAA, homovanillic acid (HVA and 3,4-dihydroxyphenylacetic acid (DOPAC in the cerebral cortex and hippocampus of mice were determined by means of high performance liquid chromatography with electrochemical detection (HPLC-EC. The results show that a successful mouse CUMS model was established through 5 weeks of continuous unpredictable stimulation, as indicated by the significant decrease in sucrose preference and locomotor activity and increase in immobility time in the forced swim test. Chronic treatment of JYCF (1.25, 2.5 and 5 g/kg and fluoxetine (20 mg/kg significantly reversed the CUMS-induced behavioral abnormalities. JYCF (1.25, 2.5 and 5 g/kg significantly increased NE in CUMS mouse prefrontal cortex (P < 0.01, P < 0.01, P < 0.05 respectively and 5-HT in hippocampus (P < 0.05. In summary, our findings suggest that JYCF exerts comparable antidepressant-like effects to that of fluoxetine in CUMS mice. Besides, the antidepressant-like effect of JYCF is mediated by the increase of monoaminergic transmitters including 5-HT and NE.

  1. Improving fluorescence diagnosis of cancer by SLIM

    Science.gov (United States)

    Rück, Angelika; Dolp, Frank; Kinzler, Ingrid; Hauser, Carmen; Scalfi-Happ, Claudia

    2006-02-01

    Although during the last years, significant progress was made in cancer diagnosis, using either intrinsic or specially designed fluorophores, still problems exist, due to difficulties in spectral separation of highly overlapping probes or in lack of specificity. Many of the problems could be circumvented by focusing on time-resolved methods. In combination with spectral resolved detection (spectral fluorescence lifetime imaging, SLIM) highly sophisticated fluorescence lifetime imaging can be performed which might improve specificity of cell diagnosis. To record lifetime images (τ-mapping) with spectral resolution a setup was realized consisting of a laser scanning microscope equipped with a 16 channel array for time-correlated single photon counting (TCSPC) and a spectrograph in front of the array. A Ti:Saphir laser can be used for excitation or alternatively ps diode lasers. With this system the time- and spectral-resolved fluorescence characteristics of different fluorophores were investigated in solution and in cell culture. As an example, not only the mitochondria staining dye rhodamine 123 could be easily distinguished from DAPI, which intercalates into nucleic acids, but also different binding sites of DAPI. This was proved by the appearance of different lifetime components within different spectral channels. Another example is Photofrin, a photosensitizer which is approved for bladder cancer and for palliative lung and esophageal cancer in 20 countries, including the United States, Canada and many European countries. Photofrin is a complex mixture of different monomeric and aggregated porphyrins. The phototoxic efficiency during photodynamic therapy (PDT) seems to be correlated with the relative amounts of monomers and aggregates. With SLIM different lifetimes could be attributed to various, spectrally highly overlapping compounds. In addition, a detailed analysis of the autofluorescence by SLIM could explain changes of mitochondrial metabolism during

  2. Treating Vitiligo in Progression Stage With Traditional Chinese Medicine Anti-vitiligo Capsule Joint Stimulation Melanocyte Granules%中药克白抑扩胶囊联合促黑冲剂治疗进展期白癜风

    Institute of Scientific and Technical Information of China (English)

    薛长连; 张克凌; 路建伟

    2011-01-01

    Objective: To observed the clinical curative effect of treating vitiligo with traditional Chinese medicine " Anti-vitiligo Capsule" joint "Stimulation Melanocyte Granules" . Methods: The 80 cases of vitiligo in progression stage were divided randomly into two groups. The treating group had 40 cases treated by traditional Chinese medicine "Anti-vitiligo Capsule" joint "Stimulation Melanocyte Granules", and treated by the "Anti-vitiligo Tincture" for external application. The control group had also 40 cases treated by "Anti-vitiligo Capsule", and treated by the "Anti-vitiligo Tincture" for external application. Result: The total effective rate of treating group and control group were 97.1% and 96.2%. There are no significant Different between the two group therapeutic effect ( P>0.001 ). The total recovery rate of treating group and control group were 48.6% and 36.4%. There are significantly different between the two group therapeutic effect ( P<0.001 ). Conclusion: The result suggested that traditional Chinese medicine "Anti-vitiligo Capsule" joint "Stimulation Melanocyte Granules" is better for treating vitiligo.%目的:观察中药克白抑扩胶囊联合促黑冲剂治疗白癜风的进展期疗效.方法:对80例进展期白癜风患者进行随机分组,治疗组40例口服中药克白抑扩胶囊联合促黑冲剂,克白酊外涂;对照组40例口服中药克白抑扩胶囊,克白酊外涂.结果:治疗组与对照组总有效率97.1%和96.2%,两组比较P>0.001,表明两组总有效率无明显差异.痊愈率分别为48.6%和36.4%,两组比较P<0.001,表明治疗组的痊愈率明显优于对照组.结论:中药克白抑扩胶囊联合促黑冲剂能够提高白癜风的痊愈率,治疗白癜风进展期疗效确切.

  3. Imperfection of Chinese Pharmacopeia (CHP,2010, part Ⅰ)Relating to Liuweidihuang capsules%对《中国药典》2010版一部六味地黄胶囊的商榷

    Institute of Scientific and Technical Information of China (English)

    杨锋; 李茜; 费嘉; 武晓琼

    2012-01-01

    目的 探索六味地黄胶囊合理的制备工艺和质量标准.方法 通过对2010年版《中国药典》一部六味地黄胶囊的制备及检验的实际应用,发现一些值得商榷的地方.结果 根据《中国药典》生产后的得率过高(247.6%),定量检验的目标物与原药材不符.结论 建议更改生产工艺及质量标准.%Objective To explore the proper preparations and quality standard of Liuweidihuang capsules. Methods Based on practical applications of preparation and test defined by Chinese Pharmacopeia (ChP, 2010, part I ) , it was found that the production of Liuweidihuang capsules needed to be improved. Results The yield of production was too high, and the object for quantitative test was incompatible with crude drugs. Conclusion The standard of preparation and quality control should be modified.

  4. Scanning Laser Infrared Molecular Spectrometer (SLIMS)

    Science.gov (United States)

    Scott, David C.; Rickey, Kelly; Ksendzov, Alexander; George, Warren P.; Aljabri, Abdullah S.; Steinkraus, Joel M.

    2012-01-01

    This prototype innovation is a novel design that achieves very long, effective laser path lengths that are able to yield ppb (parts per billion) and sub-ppb measurements of trace gases. SLIMS can also accommodate multiple laser channels covering a wide range of wavelengths, resulting in detection of more chemicals of interest. The mechanical design of the mirror cell allows for the large effective path length within a small footprint. The same design provides a robust structure that lends itself to being immune to some of the alignment challenges that similar cells face. By taking a hollow cylinder and by cutting an elliptically or spherically curved surface into its inner wall, the basic geometry of a reflecting ring is created. If the curved, inner surface is diamond-turned and highly polished, a surface that is very highly reflective can be formed. The surface finish can be further improved by adding a thin chrome or gold film over the surface. This creates a high-quality, curved, mirrored surface. A laser beam, which can be injected from a small bore hole in the wall of the cylinder, will be able to make many low-loss bounces around the ring, creating a large optical path length. The reflecting ring operates on the same principle as the Herriott cell. The difference exists in the mirror that doesn't have to be optically aligned, and which has a relatively large, internal surface area that lends itself to either open air or evacuated spectroscopic measurements. This solid, spherical ring mirror removes the possibility of mirror misalignment caused by thermal expansion or vibrations, because there is only a single, solid reflecting surface. Benefits of the reflecting ring come into play when size constraints reduce the size of the system, especially for space missions in which mass is at a premium.

  5. Culture, Constructivism, and Media: Designing a Module on Carlos Slim

    OpenAIRE

    Agudo, Roberto Rey

    2012-01-01

    Mexican tycoon Carlos Slim Helú has been a fixture on Forbes’s list of billionaires since 1991, and for the past three years, he has topped the magazine’s list of the world’s richest men. Although he is exceptionally well-known in his native Mexico, the majority of American college students have never heard of Carlos Slim. This article presents a curricular module built around this charismatic and controversial figure. The module requires students to navigate Internet-supported news media in ...

  6. Congruences of fork extensions of slim semimodular lattices

    OpenAIRE

    Grätzer, George

    2013-01-01

    For a slim, planar, semimodular lattice $L$ and covering square~$S$, G.~Cz\\'edli and E.\\,T.~Schmidt introduced the fork extension, $L[S]$, which is also a slim, planar, semimodular lattice. We investigate when a congruence of $L$ extends to $L[S]$. We introduce a join-irreducible congruence $\\boldsymbol{\\gamma}(S)$ of $L[S]$. We determine when it is new, in the sense that it is not generated by a join-irreducible congruence of $L$. When it is new, we describe the congruence $\\boldsymbol{\\gamm...

  7. Use of slim holes for geothermal exploration and reservoir assesment: A preliminary report on Japanese experience

    Energy Technology Data Exchange (ETDEWEB)

    Garg, S.K.; Combs, J.

    1993-01-28

    The publicly available Japanese data on the use of slim holes in geothermal exploration and reservoir assessment are reviewed in this report. Slim holes have been used for (1) obtaining core for geological studies, (2) delineating the stratigraphic structure, (3) characterizing reservoir fluid state (pressure, temperature, etc.), and (4) defining the permeability structure for reservoir assessment. Examples of these uses of slim hole data are presented from the Hohi Geothermal Area and the Sumikawa Geothermal Field. Discharge data from slim holes and production wells from the Oguni Geothermal Field indicate that it may be possible to infer the discharge rate of production wells based on slim hole measurements.

  8. Effects of Xuezhikang Capsule (血脂康胶囊) on High Risk Population in Chinese Coronary Secondary Prevention Study (CCSPS) and the Enlightenment from It

    Institute of Scientific and Technical Information of China (English)

    XU Zhi-min

    2006-01-01

    @@ Summery of CCSPS Trial and Its Sub-group Analysis Chinese coronary secondary prevention study (CCSPS), one of the key items of the Ninth Five-year Plan of China, is a largescale multicenter, randomized, double-blinded and placebo controlled clinical trial. From May 1996 to Dec.

  9. Fatboy Slim ja David Byrne teevad Imelda Marcosest muusikali

    Index Scriptorium Estoniae

    2005-01-01

    Inglise DJ Fatboy Slim'i ja USA art-rockmuusiku David Byrne'i diskokeskne muusikal "Here Love Lives" kajastab Filipiinide diktaatori Ferdinand Macrose abikaasa elu. Muusikal esietendub tuleva aasta märtsis Austraalias Adelaide'i kultuurifestivalil, Euroopa esietendus toimub seejärel Liverpoolis

  10. A Review of "Slim Hopes: Advertising & The Obsession with Thinness."

    Science.gov (United States)

    Couch, Richard

    This paper reviews "Slim Hopes: Advertising & The Obsession with Thinness," a 30-minute video produced by the University of Massachusetts' Media Education Foundation, which discusses America's compulsion with thinness. Although the format of the video is the traditional "talking head," over 120 print and television advertisements are used to…

  11. Use of slim holes for geothermal exploration and reservoir assessment: A preliminary report on Japanese experience

    Energy Technology Data Exchange (ETDEWEB)

    Garg, S.K. [S-Cubed, La Jolla, CA (United States); Combs, J. [Geo Hills Associates, Los Altos Hills, CA (United States)

    1993-06-01

    The publicly available Japanese data on the use of slim holes in geothermal exploration and reservoir assessment are reviewed in this report. Slim holes have been used for (1) obtaining core for geological studies, (2) delineating the stratigraphic structure, (3) characterizing reservoir fluid state (pressure, temperature, etc.), and (4) defining the permeability structure for reservoir assessment. Examples of these uses of slim hole data are presented from the Hohi Geothermal Area and the Sumikawa Geothermal Field. Discharge data from slim holes and production wells from the Oguni Geothermal Field indicate that it may be possible to infer the discharge rate of production wells based on slim hole measurements. The Japanese experience suggests that slim holes can provide useful data for cost-effective geothermal reservoir assessment. Therefore, plans for a full scale evaluation of Japanese slim hole data are outlined.

  12. Pneumatic Capsule Pipeline

    OpenAIRE

    ECT Team, Purdue

    2007-01-01

    Pneumatic capsule pipeline (PCP) uses wheeled capsules (vehicles) to carry cargoes through a pipeline filled with air. Modern large diameter PCP systems utilize through flow booster pumps, also known as jet pump injectors. These create the pressure differentials required to propel multiple capsules through a pipeline, while allowing both terminals at atmospheric pressure. This is done by placing a booster pump midway along the pipeline, and designing it in such a way that capsules can bypass ...

  13. Colon capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    Ignacio Fernandez-Urien; Cristina Carretero; Ana Borda; Miguel Mu(n)oz-Navas

    2008-01-01

    Wireless capsule endoscopy has become the first imaging tool for small bowel examination.Recently,new capsule endoscopy applications have been developed,such as esophageal capsule endoscopy and colon capsule endoscopy.Clinical trials results have shown that colon capsule endoscopy is feasible,accurate and safe in patients suffering from colonic diseases.It could be a good alternative in patients refusing conventional colonoscopy or when it is contraindicated.Upcoming studies are needed to demonstrate its utilty for colon cancer screening and other indications such us ulcerative colitis.Comparative studies including both conventional and virtual colonoscopy are also required.

  14. Esophageal capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    Ignacio Fernandez-Urien; Cristina Carretero; Raul Armendariz; Miguel Mu(n)oz-Navas

    2008-01-01

    Capsule endoscopy is now considered as the first imaging tool for small bowel examination.Recently,new capsule endoscopy applications have been developed,such as esophageal capsule endoscopy and colon capsule endoscopy.Esophageal capsule endoscopy in patients with suspected esophageal disorders is feasible and safe,and could be also an alternative procedure in those patients refusing upper endoscopy.Although large-scale studies are needed to confirm its utility in GERD and cirrhotic patients,current results are encouraging and open a new era in esophageal examination.

  15. A Standardized Traditional Chinese Medicine Preparation Named Yejuhua Capsule Ameliorates Lipopolysaccharide-Induced Acute Lung Injury in Mice via Downregulating Toll-Like Receptor 4/Nuclear Factor-κB

    Directory of Open Access Journals (Sweden)

    Chu-Wen Li

    2015-01-01

    Full Text Available A standardized traditional Chinese medicine preparation named Yejuhua capsule (YJH has been clinically used in treatments of various acute respiratory system diseases with high efficacy and low toxicity. In this study, we were aiming to evaluate potential effects and to elucidate underlying mechanisms of YJH against lipopolysaccharide- (LPS- induced acute lung injury (ALI in mice. Moreover, the chemical analysis and chromatographic fingerprint study were performed for quality evaluation and control of this drug. ALI was induced by intratracheal instillation of LPS (5 mg/kg into the lung in mice and dexamethasone (5 mg/kg, p.o. was used as a positive control drug. Results demonstrated that pretreatments with YJH (85, 170, and 340 mg/kg, p.o. effectively abated LPS-induced histopathologic changes, attenuated the vascular permeability enhancement and edema, inhibited inflammatory cells migrations and protein leakages, suppressed the ability of myeloperoxidase, declined proinflammatory cytokines productions, and downregulated activations of nuclear factor-κB (NF-κB and expressions of toll-like receptor 4 (TLR4. This study demonstrated that YJH exerted potential protective effects against LPS-induced ALI in mice and supported that YJH was a potential therapeutic drug for ALI in clinic. And its mechanisms were at least partially associated with downregulations of TLR4/NF-κB pathways.

  16. Potential and limitation when utilizing slim hole drilling

    OpenAIRE

    Sivertsen, Trond Eggen

    2010-01-01

    The objective of this master thesis was to evaluate and identify the potential and limitations when slim well technologies are implemented in the basis of design (BOD). The obvious potential from reducing the conventional well construction used at present will have a positive effect on the economical and environmental impact.Several technologies are evaluated separately and combined in order to present an optimal well construction and layout for a successful drilling operation. Both productio...

  17. Verification of the Determination of Chromium Content in a Chinese Medicine Capsule by ICP-MS Method%ICP-MS法测定某中药胶囊中铬含量的方法验证

    Institute of Scientific and Technical Information of China (English)

    宋艳刚; 李波; 王国祥

    2015-01-01

    Objective: To testify the determination of chromium content in a Chinese Medicine capsule by ICP-MS method. Methods:The linearity, precision, reproducibility, average recovery rate of the method were inves-tigated, the results were compared with the method (atomic absorption spectrometry, AAS) in the pharmacopeia. Re-sults:the standard curve of chromium is in the concentrations ranged from 0 to 100ng/g with good linearity, correla-tion coefficient r=0.999 9, the detection limit is 0.02ng/g, quantitative limit is 0.07ng/g, high precision of the instru-ment, good repeatability and recovery rate of the samples show that the method is reliable and accurate. Conclusion:Measured value of the method is higher than the method in the pharmacopeia, which demonstrates that the method is of higher sensibility, the method could be applied to detect chromium content in the capsules in the practical work.%目的:验证ICP-MS法测定胶囊剂药品中铬含量的方法。方法:考察该方法的线性、精密度、重复性、加样回收率,并将测得结果与药典方法(原子吸收光谱法)进行比较。结果:铬元素标准曲线在0~100 ng/g浓度范围内,线性良好,相关系数r=0.9999,检测限为0.02 ng/g,定量限为0.07 ng/g,仪器精密度、样品重复性和回收率良好,表明该方法准确可靠。结论:该方法实测值较药典方法高,说明其灵敏度更高,可以在实际工作中运用此方法检测胶囊剂药品中的铬元素含量。

  18. Development of slim-maud: a multi-attribute utility approach to human reliability evaluation

    International Nuclear Information System (INIS)

    This paper describes further work on the Success Likelihood Index Methodology (SLIM), a procedure for quantitatively evaluating human reliability in nuclear power plants and other systems. SLIM was originally developed by Human Reliability Associates during an earlier contract with Brookhaven National Laboratory (BNL). A further development of SLIM, SLIM-MAUD (Multi-Attribute Utility Decomposition) is also described. This is an extension of the original approach using an interactive, computer-based system. All of the work described in this report was supported by the Human Factors and Safeguards Branch of the US Nuclear Regulatory Commission

  19. Study on Bioequivalence of Cefdinir Capsules in Chinese Healthy Volunteers%头孢地尼胶囊在健康人体的生物等效性研究

    Institute of Scientific and Technical Information of China (English)

    陈芬; 朱超然; 翟学佳; 冯霞; 邓桂萍; 郭卿; 蒋立芬; 吕永宁

    2015-01-01

    目的:评价健康人餐后服用两种头孢地尼胶囊的生物等效性。方法24例男性健康志愿者餐后随机交叉单剂量口服头孢地尼胶囊受试制剂或参比制剂,头孢地尼体内血药浓度采用液相色谱-质谱串联( LC-MS/MS)法测定,药动学参数及等效性采用药动学软件DAS计算和评价。结果受试制剂和参比制剂的主要药动学参数如下:AUCt分别为(4.35±1.09)和(4.12±1.22)μg��h��mL-1,AUC0-∞分别为(4.53±1.12)和(4.53±1.73)μg��h��mL-1,t1/2分别为(1.74±0.29)和(2.13±1.65) h,tmax分别为(4.44±0.86)和(4.54±1.16) h,Cmax分别为(900±250)和(876±269) ng��mL-1。结论头孢地尼胶囊受试制剂与参比制剂具有生物等效性。%Objective To evaluate postprandial pharmacokinetics and bioequivalence of two preparations of cefdinir capsules in Chinese healthy volunteers. Methods In a two-way cross-over study, 24 healthy male volunteers were divided into two groups randomly and a single dose of cefdinir capsules of test and reference preparation were administered orally, respectively.The concentration in plasma was determined by LC-MS/MS. Pharmacokinetic parameters and bioequivalence were calculated and evaluated by DAS. Results The main pharmacokinetic parameters of test and reference were as follows: AUCt (4.35±1.09) μg��h��mL-1 and (4.12±1.22) μg��h��mL-1, AUC0-∞(4.53±1.12) and (4.53±1.73) μg��h��mL-1, t1/2 (1.74±0.29) h and (2.13±1.65) h, tmax(4.44±0.86) h and (4.54 ±1.16) h, Cmax(900±250) ng��mL-1 and (876±269) ng��mL-1 . Conclusion The test and reference preparation of cefdinir capsules are bioequivalent.

  20. 更昔洛韦分散片和胶囊在健康人体中的生物等效性%Bioequivalence of ganciclovir dispersible tablets and capsules in Chinese healthy volunteers

    Institute of Scientific and Technical Information of China (English)

    刘茜; 邓琳琳; 赵辉; 张旭; 刘洋

    2011-01-01

    目的 研究更昔洛韦分散片和胶囊在人体内的生物等效性.方法 采用双交叉随机自身对照试验设计,20名健康受试者分别单剂量口服更昔洛韦胶囊和分散片1 000 mg后,采用HPLC法测定血药浓度,DAS2.0软件计算药动学参数,并进行等效性检验.结果 更昔洛韦分散片和胶囊的主要药动学参数:pmax分别为(0.58±0.18)和(0.60±0.20)mg·L-1,Tmax分别为(3.0±0.4)和(3.2±0.4)h,t1/2分别为(4.6±1.3)和(4.6±0.8)h,AUC0-t分别为(2.8±0.8)和(3.2±1.2)mg·h·L-1,更昔洛韦分散片和胶囊的平均相对生物利用度为(96±28)%.结论 更昔洛韦分散片和胶囊在人体内生物等效.%AIM To evaluate the bioequivalence of ganciclovir dispersible tablets and capsules in Chinese healthy volunteers.METHODS In a randomized, crossover and self-controlled study, 20 male healthy volunteers were administered with a single oral dose of test and reference preparations containing 1 000 mg ganciclovir, respectively.The plasma concentrations of ganciclovir were determined by HPLC-UV.The pharmacokinetic parameters were calculated and the bioequivalence of the two preparations was evaluated by DAS software 2.0.RESULTS The main pharmacokinetic parameters of the ganciclovir dispersible tablets and capsules were as follows: pmax were (0.58 ± 0.18) and (0.60 ± 0.20) mg·L-1, τmax were (3.0 ± 0.4) and (3.2 ± 0.4) h, t1/2 were (4.6 ± 1.3) and (4.6 ± 0.8) h, AUC0-t were (2.8 ± 0.8) and (3.2 ± 1.2) mg·h·L-1.The relative bioavailability of ganciclovir dispersible tablets was (96 ± 28) %.CONCLUSION Ganciclovir dispersible tablets and capsules are bioequivalent.

  1. Evaluation of Seismic Performance and Effectiveness of Multiple Slim-Type Damper System for Seismic Response Control of Building Structures

    OpenAIRE

    David Kim; Eun Hee Sung; Kwan-Soon Park; Jaegyun Park

    2014-01-01

    This paper presents the evaluation of seismic performance and cost-effectiveness of a multiple slim-type damper system developed for the vibration control of earthquake excited buildings. The multiple slim-type damper (MSD) that consists of several small slim-type dampers and linkage units can control damping capacity easily by changing the number of small dampers. To evaluate the performance of the MSD, dynamic loading tests are performed with three slim-type dampers manufactured at a real s...

  2. Pharmacokinetics of tenofovir disoproxil fumarate capsule in Chinese volunteers%富马酸替诺福韦二吡呋酯胶囊在中国人体内的药代动力学

    Institute of Scientific and Technical Information of China (English)

    姜莉苑; 丁黎; 钟水生; 刘冰; 陈迪; 文爱东

    2013-01-01

    To investigate the pharmacokinetics of tenofovir disoproxil fumarate (TDF) capsule in Chinese volunteers.A phase Ⅰ,3-period study was performed in healthy Chinese subjects.12 Healthy subjects received either single 300 mg,multiple 300 mg and single 600 mg doses of TDF under fasted conditions,or received single 300 mg doses under fed condition.For 300 mg and 600 mg single administration of TDF,the cmax data were (305.4 ±96.4) and (590.0 ± 149.6) ng/mL,respectively,and the AUC0-72 h data were (2 396 ± 489) and (4 465 ±1 042) ng· h/mL,respectively.In the dose range of 300-600 mg,tenofovir demonstrated linear pharmacokinetic characteristics in Chinese volunteers.No significant gender difference in the pharmacokinetic parameters was found.High fat food decreased the absorption rate of tenofovir,but increased its exposure.In the multiple-dose study at 300 mg dose for 7 consecutive days,the degree of fluctuation (DF) was 2.7 ± 0.6,and the accumulation parameter (Rcmax) and (RAUC) were 1.3 ±0.3 and 1.7 ±0.4,respectively.Compared with the single dose administration,an increased exposure of 70% in AUC0-τ of tenofovir was observed after a multiple administration.%研究富马酸替诺福韦二吡呋酯胶囊在中国人体内的药代动力学特征.12名健康受试者依次进行低剂量(300mg)单、多次给药;高(600 mg)剂量单次给药和低剂量饮食影响单次给药的药代动力学试验,计算药代动力学参数.受试者单次口服300 mg和600 mg受试制剂后,替诺福韦的cmax分别为(305.4±96.4)和(590.0±149.6)ng/mL,AUC0-72h分别为(2 396±489)和(4 465±1 042) ng·h/mL,t1/2分别为(19.9±2.4)和(21.9±3.0)h.结果显示替诺福韦在300 ~ 600 mg剂量范围内呈现线性药代动力学特征,体内过程不受性别差异的影响.与空腹给药相比,高脂餐后给药的tmax延后1.6h,AUC0-72 h提高约32%.多次给药达稳态后,替诺福韦的稳态血药浓度波动度为2.7±0.6,累积常数Rcmax为1.3±0.3,RAUC为1

  3. Bioequivalence of Clarithromycin soft capsules in healthy Chinese volunteers%克拉霉素软胶囊在中国健康人体的生物等效性研究

    Institute of Scientific and Technical Information of China (English)

    马萍; 李鹏飞; 王淑民; 汪娟; 王燕; 谢晓娟; 刘丽宏

    2012-01-01

    AIM: To evaluate the bioequivalence of Clarithromycin soft capsule in healthy Chinese volunteers. METHODS: A single oral doses of 0. 25 g Clarithromycin soft capsule and tablet (test and reference) were given to 20 healthy volunteers according to an open randomized crossover design. The concentrations of Clarithromycin in plasma were determined by LC-MS/MS. With the aid of BAPP2. 0.the bioequivalence of the test and reference preparation were calculated by analysis of variance, tow one sided t-test. RESULTS: The pharmacokinetic parameters of the two preparations were as follow ;tmax of test drug and reference drug were (2. 1 ± 0. 6),(2.0 + 0. 8)h, Cmax were(815 + 191),(800 ±200) ng/mL, t1/2 were (4. 0 + 0. 4)、 (3. 9 ± 0.5) h, AUC0-24, were (5612 ± 1283), (5246 ± 1375) ng·h·mL-1, AUC0-∞ were (5722 ± 1313),(5339± 1402) ng · h · mL-1 , respectively. The relative bioavailability of the test formulation were (110.5 + 23.9)%. CONCLUSION: The tested preparation was of bioequivalence to the reference preparation.%目的:评价受试制剂克拉霉素软胶囊与参比制剂克拉霉素片在中国健康人体中的生物等效性.方法:采用双周期随机交叉试验设计,入选20名男性健康受试者单剂空腹口服参比制剂和受试制剂0.25g,采用液相色谱-串联质谱法(LC-MS/MS)测定血浆中克拉霉素的浓度,经BAPP2.0软件处理参数,并进行双单侧t检验确定是否生物等效.结果:主要药代动力学参数:受试制剂和参比制剂克拉霉素的达峰时间tmax分别为(2.1±0.6)、(2.0±0.8)h;Cmax分别为(815±191)、(800±200)ng/mL;t1/2分别为(4.0±0.4)、(3.9±0.5)h;AUC0-24h分别为(5612±1283)、(5246±1375)ng·h·mL-1;AUC0-∝分别 为 (5722 ± 1313)、 (5339 ±1402) ng·h·mL-1.受试制剂与参比制剂的相对生物利用度为(110.5±23.9)%.结论:受试制剂克拉霉素软胶囊与参比制剂克拉霉素片生物等效.

  4. Slim-hole drilling in the Gulf of Suez, Egypt

    International Nuclear Information System (INIS)

    This paper discusses the economical, operational and environmental aspects of the reduced hole size drilling now used in offshore operations in Gupco and other major petroleum companies operating in the Gulf of Suez Area Egypt. The results demonstrate that reduced hole size drilling saves cost: use of slim hole reduces time related intangible savings, fixed tangible savings, and tangible equipment savings. The advantages of small hole size and the reduction in the volume and size of oil wet drilling cuttings help minimize the environmental impact associated with the use of oil base mud. The reduction in drilling fluid volume and treatment cost, higher rates of penetration, better hole cleaning capabilities, savings in consumables (such as bits, mud, cement and diesel oil), less tangible cost, and easier equipment mobilization are interacted to produce significant operational gains. This results in savings to 40 to 50 percent of well costs versus the cost of conventional wells drilled in the same area. Although substantial savings were realized, there are elevated risks with the major one being the lack of a good contingency in the event unexpected hole condition or geological condition require an extra casing to be run prior to reaching the total depth. Effective preplanning between the drilling, exploration, and engineering to accurately define possible geologic targets and their potential drilling problems can minimize these risks associated with drilling slim holes and provide higher levels of success in meeting objectives

  5. Management of adhesive capsulitis

    OpenAIRE

    Neviaser, Andrew

    2015-01-01

    Kristen L Stupay,1 Andrew S Neviaser2 1Tulane University School of Medicine, New Orleans, LA, USA; 2George Washington University Medical Faculty Associates, Washington, DC, USA Abstract: Adhesive capsulitis of the shoulder is a condition of capsular contracture that reduces both active and passive glenohumeral motion. The cause of adhesive capsulitis is not known but it is strongly associated with endocrine abnormalities such as diabetes. Diverse terminology and the absence of definitive cri...

  6. Pharmacokinetics of diltiazem hydrochloride delay-onset sustained-release pellet capsules in healthy volunteers

    OpenAIRE

    Xi-Qing Yan; Zhi-Gang Chen; Rong-Liang Wang; Jun Yang; Fang Ai; Yan-Juan Pan; Pei-Yong Qiu; Da-Xin Wang

    2013-01-01

    The pharmacokinetics (PK) of ordinary tablets and sustained release capsules of diltiazem hydrochloride in human clinical trials had been studied. The PK of diltiazem hydrochloride delay-onset sustained-release pellet capsules, a new dosage form, has not been reported, although it is very important to clinical use. In this paper, we investigated the PK of diltiazem hydrochloride delay-onset sustained-release pellet capsules and the food influence in Chinese healthy volunteers. The PK paramete...

  7. Capsule contraction syndrome

    Directory of Open Access Journals (Sweden)

    Mesut COŞKUN

    2009-06-01

    Full Text Available Capsule contraction syndrome occurs after fibrous metaplasia of lens proteins that leads to capsular bag contraction. Excessive front capsular wrinkling is seen in capsule contraction syndrome and there is an imbalance between powers supplying capsular integrity. This situation leads to zonular weakness. Capsule contraction syndrome is associated with pseudoexfoliation, older age, uveitis, pars planitis and myotonic muscular dystrophy. In order to decrease the risk of capsule contraction syndrome, front capsulerhexis area should be open as 5.5-6 mm diameter and a curysoft intraocular lens should be used. In order to prevent lens epithelial proliferation and metaplasia, lens epithelial cells at inferior surface of front capsule should be aspirated carefully. If postoperative capsular contraction detected, front capsulotomy should be performed by Nd-YAG laser at postoperative 2 to 3 weeks. In patients that Nd-YAG laser is unsuccessful, capsular tension should be decreased by surgical microincisions. In present study, we evaluated etiology, prevention and management of capsule contraction syndrome in the light of actual literature knowledge.

  8. Treatment of hyperlipoidemia by Xiaozhi capsule: a clinical efficacy research

    Institute of Scientific and Technical Information of China (English)

    王建平

    2013-01-01

    Objective To observe the clinical effect and efficacy of Xiaozhi Capsule (XZC) ,a Chinese medicine preparation for tonifying Gan-Shen,invigorating Pi to dissipate dampness (TGSIPDD) on total cholesterol (TC) ,triglyceride (TG) ,high-density lipoprotein cholesterol (HDLC) ,low-density lipoprotein cholesterol (LDL-C) ,and

  9. Domotica Smart Living. Special issue; Domotica Slim Wonden. Themanummer

    Energy Technology Data Exchange (ETDEWEB)

    Lepelaars, L. [Stichting Smart Homes, eersel (Netherlands); Hamers, E. [Van Dorp Installaties, Zoetermeer (Netherlands); Van Mil, R.

    2011-10-15

    In a few articles (introduction, interview and 3 articles) attention is paid to domotica applications and smart living. The interview is with a professor 'ambient robotics' at the University of Amsterdam. The articles are about (1) the activities of the Smart Homes Foundation, (2) the use of domotica in the health and homecare sector, and (3) the use of domotica to improve comfort, safety and efficiency. [Dutch] In een paar artikelen (voorwoord, interview en 3 artikelen) wordt aandacht besteed aan domotica toepassingen en slim wonen. Het interview betreft een bijzonder hoogleraar 'ambient robotics aan de Universiteit van Amsterdam. De artikelen gaan over de activiteiten van de Stichting Smart Homes, (2) de toepassingen van domotica in de thuiszorg, en (3) het gebruik van domotica om het comfort, de veiligheid en energie efficiency te verbeteren.

  10. The Virginia Slims identity crisis: an inside look at tobacco industry marketing to women

    OpenAIRE

    Toll, B; Ling, P

    2005-01-01

    Objectives: Because no prior studies have comprehensively analysed previously secret tobacco industry documents describing marketing female brands, the Virginia Slims brand was studied to explore how Philip Morris and competitors develop and adapt promotional campaigns targeting women.

  11. A Structures for Lossless Ion Manipulations (SLIM) Module for Collision Induced Dissociation

    Science.gov (United States)

    Webb, Ian K.; Garimella, Sandilya V. B.; Norheim, Randolph V.; Baker, Erin S.; Ibrahim, Yehia M.; Smith, Richard D.

    2016-07-01

    A collision induced dissociation (CID) structure for lossless ion manipulations (SLIM) module is introduced and coupled to a quadrupole time-of-flight (QTOF) mass spectrometer. The SLIM CID module was mounted after an ion mobility (IM) drift tube to enable IM/CID/MS studies. The efficiency of CID was studied by using the model peptide leucine enkephalin. CID efficiencies (62%) compared favorably with other beam-type CID methods. Additionally, the SLIM CID module was used to fragment a mixture of nine peptides after IM separation. This work also represents the first application of SLIM in the 0.3 to 0.5 Torr pressure regime, an order of magnitude lower in pressure than previously studied.

  12. A Structures for Lossless Ion Manipulations (SLIM) Module for Collision Induced Dissociation

    Energy Technology Data Exchange (ETDEWEB)

    Webb, Ian K.; Garimella, Venkata BS; Norheim, Randolph V.; Baker, Erin Shammel; Ibrahim, Yehia M.; Smith, Richard D.

    2016-07-01

    A collision induced dissociation (CID) structures for lossless ion manipulations (SLIM) module is introduced and coupled to a quadrupole time-of-flight (QTOF) mass spectrometer (MS). The SLIM CID module was mounted after an ion mobility (IM) drift tube to enable IM/CID/MS studies. The efficiency of CID was studied by using the model peptide leucine enkephalin. CID efficiencies (62%) compared favorably to other beam-type CID methods. Additionally, the SLIM CID module was used to fragment a mixture of 9 peptides after IM separation. This work also represents the first application of SLIM in the 0.3 to 0.5 Torr pressure regime, an order of magnitude lower in pressure than previously studied.

  13. Gelatin capsule in stomach (image)

    Science.gov (United States)

    ... detect the presence of intestinal parasites. A weighted gelatin capsule attached to a string is swallowed and left in place. After about 4 hours, the gelatin capsule is pulled out of the stomach by ...

  14. Topography and refractometry of nanostructures using spatial light interference microscopy (SLIM)

    OpenAIRE

    Wang, Zhuo; Chun, Ik Su; Li, Xiuling; Ong, Zhun-Yong; Pop, Eric; Millet, Larry; Gillette, Martha; Popescu, Gabriel

    2010-01-01

    Spatial Light Interference Microscopy (SLIM) is a novel method developed in our laboratory that provides quantitative phase images of transparent structures with 0.3 nm spatial and 0.03 nm temporal accuracy owing to the white light illumination and its common path interferometric geometry. We exploit these features and demonstrate SLIM's ability to perform topography at a single atomic layer in graphene. Further, using a decoupling procedure that we developed for cylindrical structures, we ex...

  15. Epidemicsof Abundance: Overeating and Slimming in the USA and Britain since the 1950s

    OpenAIRE

    Avner Offer

    1998-01-01

    Body weight has risen in defiance of health and appearance norms. The social epidemics of overeating and slimming were driven by market forces and the psychology of eating: restrained eating is easily disinhibited by stress. For men, the rise in body weight was associated with the decline of family eating and exposure to greater food variety. For women, the cult of slimming was associated with mating competition, driven initially by adverse sex ratios. Food abundance made a mockery of the rat...

  16. Cardiomyocyte Imaging Using Real-Time Spatial Light Interference Microscopy (SLIM)

    OpenAIRE

    Bhaduri, Basanta; Wickland, David; Wang, Ru; Chan, Vincent; Bashir, Rashid; Popescu, Gabriel

    2013-01-01

    Spatial light interference microscopy (SLIM) is a highly sensitive quantitative phase imaging method, which is capable of unprecedented structure studies in biology and beyond. In addition to the π/2 shift introduced in phase contrast between the scattered and unscattered light from the sample, 4 phase shifts are generated in SLIM, by increments of π/2 using a reflective liquid crystal phase modulator (LCPM). As 4 phase shifted images are required to produce a quantitative phase image, the sw...

  17. Wireless capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    A Mata; J Llach; JM Bordas

    2008-01-01

    Wireless capsule endoscopy is a new technique that allows complete exploration of the small bowel without external wires. Its role has been analyzed in many small bowel diseases such as obscure gastrointestinal bleeding, Crohn's disease and gastrointestinal polyposis syndromes with promising results. Studies on other pathologies (I.e. Small bowel tumour, celiac disease) are under evaluation to define the role of this technique.

  18. Mechanism of Erhuang capsule for treatment of multiple sclerosis

    Institute of Scientific and Technical Information of China (English)

    Kangning Li; Yongping Fan; Tao Yang; Lei Wang

    2013-01-01

    Erhuang capsule, a typical formula based on traditional Chinese medicine theory, is widely used to ameliorate multiple sclerosis, inflammation and side effects of glucocorticoid treatment. Oligodendrocyte precursor cells are neural stem cells that are important for myelin repair and regeneration. In the present study, Erhuang capsule effectively improved clinical symptoms and neurological function scores, reduced mortality and promoted recovery of neurological functions of mice with experimental autoimmune encephalomyelitis. The mechanism of action involved significant increases in oligodendrocyte precursor cell proliferation in specific regions of the brain and spinal cord, increased oligodendrocyte lineage gene 2 expression and enhanced oligodendrocyte precursor cell differentiation.

  19. Management of adhesive capsulitis

    Directory of Open Access Journals (Sweden)

    Stupay KL

    2015-08-01

    Full Text Available Kristen L Stupay,1 Andrew S Neviaser2 1Tulane University School of Medicine, New Orleans, LA, USA; 2George Washington University Medical Faculty Associates, Washington, DC, USA Abstract: Adhesive capsulitis of the shoulder is a condition of capsular contracture that reduces both active and passive glenohumeral motion. The cause of adhesive capsulitis is not known but it is strongly associated with endocrine abnormalities such as diabetes. Diverse terminology and the absence of definitive criteria for diagnosis make evaluating treatment modalities difficult. Many treatment methods have been reported, most with some success, but few have been proved to alter the natural course of this disease. Most afflicted patients will achieve acceptable shoulder function without surgery. Those who remain debilitated after 8–12 months are reasonable candidates for invasive treatments. Here, the various treatment methods and the data to support their use are reviewed. Keywords: frozen shoulder, stiff shoulder, periarthritis, painful shoulder 

  20. Slim accretion discs a model for ADAF-SLE transitions

    CERN Document Server

    Igumenshchev, I V; Novikov, I D

    1997-01-01

    We numerically construct slim, global, vertically integrated models of optically thin, transonic accretion discs around black holes, assuming a regularity condition at the sonic radius and boundary conditions at the outer radius of the disc and near the black hole. In agreement with several previous studies, we find two branches of shock-free solutions, in which the cooling is dominated either by advection, or by local radiation. We also confirm that the part of the accretion flow where advection dominates is in some circumstances limited in size: it does not extend beyond a certain outer limiting radius. New results found in our paper concern the location of the limiting radius and properties of the flow near to it. In particular, we find that beyond the limiting radius, the advective dominated solutions match on to Shapiro, Lightman & Eardley (SLE) discs through a smooth transition region. Therefore, the full global solutions are shock-free and unlimited in size. There is no need for postulating an extr...

  1. Cardiomyocyte imaging using real-time spatial light interference microscopy (SLIM.

    Directory of Open Access Journals (Sweden)

    Basanta Bhaduri

    Full Text Available Spatial light interference microscopy (SLIM is a highly sensitive quantitative phase imaging method, which is capable of unprecedented structure studies in biology and beyond. In addition to the π/2 shift introduced in phase contrast between the scattered and unscattered light from the sample, 4 phase shifts are generated in SLIM, by increments of π/2 using a reflective liquid crystal phase modulator (LCPM. As 4 phase shifted images are required to produce a quantitative phase image, the switching speed of the LCPM and the acquisition rate of the camera limit the acquisition rate and, thus, SLIM's applicability to highly dynamic samples. In this paper we present a fast SLIM setup which can image at a maximum rate of 50 frames per second and provide in real-time quantitative phase images at 50/4 = 12.5 frames per second. We use a fast LCPM for phase shifting and a fast scientific-grade complementary metal oxide semiconductor (sCMOS camera (Andor for imaging. We present the dispersion relation, i.e. decay rate vs. spatial mode, associated with dynamic beating cardiomyocyte cells from the quantitative phase images obtained with the real-time SLIM system.

  2. Design improvement of HANARO capsule

    International Nuclear Information System (INIS)

    Instrumented capsules are one of the irradiation facilities in the HANARO (Hi-Flux Advanced Neutron Application Reactor) core. The structural integrity of this structures under seismic loads and during irradiation in the reactor are issues of major concern to enhance the capsule safety. Based on the structural integrity results carried out using the finite element program, ANSYS, major components of the capsule top guide spring and the bottom guide pin are optimized through material tests

  3. Capsule endoscopy in celiac disease

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Video capsule endoscopy is an attractive and patient- friendly tool that provides high quality images of the small bowel. Obscure gastrointestinal bleeding is the primary and most evaluated indication to capsule endoscopy; however, indications are expanding and a small number of preliminary reports have been presented concerning the role of video capsule endoscopy in the diagnosis of celiac disease. The purpose of this review is to update the current knowledge and to hypothesize on future perspectives of the use of video capsule endoscopy in patients with celiac disease.

  4. Optimal Design of Capsule Transporting Pipeline carrying Spherical Capsules

    Science.gov (United States)

    Asim, Taimoor; Mishra, Rakesh; Ubbi, Kuldip

    2012-05-01

    A capsule pipeline transports material or cargo in capsules propelled by fluid flowing through a pipeline. The cargo may either be contained in capsules (such as wheat enclosed inside sealed cylindrical containers), or may itself be the capsules (such as coal compressed into the shape of a cylinder or sphere). As the concept of capsule transportation is relatively new, the capsule pipelines need to be designed optimally for commercial viability. An optimal design of such a pipeline would have minimum pressure drop due to the presence of the solid medium in the pipeline, which corresponds to minimum head loss and hence minimum pumping power required to drive the capsules and the transporting fluid. The total cost for the manufacturing and maintenance of such pipelines is yet another important variable that needs to be considered for the widespread commercial acceptance of capsule transporting pipelines. To address this, the optimisation technique presented here is based on the least-cost principle. Pressure drop relationships have been incorporated to calculate the pumping requirements for the system. The maintenance and manufacturing costs have been computed separately to analyse their effects on the optimisation process. A design example has been included to show the usage of the model presented. The results indicate that for a specific throughput, there exists an optimum diameter of the pipeline for which the total cost for the piping system is at its minimum.

  5. Overview on the Small Lunar Lander Slim and its Planetary Protection Plan

    Science.gov (United States)

    Sakai, Shinichiro

    2016-07-01

    A small experimental spacecraft "SLIM" is proposed at ISAS/JAXA to demonstrate a "pin-point" landing on the lunar surface. The spacecraft is designed to achieve 100 m-order landing ellipse in order to satisfy such needs for future surface explorations on the Moon. Since the conventional ground-based navigation system is not effective enough to achieve this level of the landing accuracy, a novel, autonomous and image-based onboard navigation system will be developed and demonstrated by the SLIM mission along with several other new technologies. Some of these new technologies aim to realize a light-weight spacecraft for future interplanetary missions. The SLIM spacecraft itself weighs ˜590 kg wet mass and ˜130kg dry mass, both of which are much lighter than any previous lunar landers. Its main engine consists of 500N-class bipropellant thruster with N2H4 and MON3. Although the SLIM's main mission is technology and operation demonstration described above, additional small scientific payloads will also be employed. Its launcher is JAXA's Epsilon rocket, and the present target launch period is in early 2020. Based on the mission scope and mission design already mentioned, the SLIM team proposes that its COSPAR planetary protection policy categorization will be the Category II, which mainly requires a planetary protection plan and other documentations, including the spacecraft organic inventory. In this talk, the overview of the SLIM mission and its planetary protection plan will be presented and discussed for requesting the COSPAR-PPP to support the Category II proposal in a timely manner.

  6. Wireless capsule endo bronchoscopy

    Directory of Open Access Journals (Sweden)

    Baratz DM

    2014-03-01

    Full Text Available No abstract available. Article truncated at 150 words. Case Presentation History of Present Illness A 67 year-old man presents 10 days after swallowing a capsule endoscopy camera that was never retrieved. The wireless capsule was swallowed asymptomatically for evaluation of heme positive stools after negative upper and lower endoscopies. Patient noted that the evening after swallowing the camera he developed mild shortness of breath and cough. The cough and shortness of breath were persistent and worsened while lying down and when moving positions. He denied prior issues with swallowing or aspiration. Review of Systems Negative other than what is noted above. PMH, SH, and FH Past medical history: coronary artery disease, peripheral vascular disease, hyperlipidemia Surgical history: femoral-popliteal bypass, previous shoulder and back surgery Social history: 1 pack/day of cigarettes for 50 years, prior alcohol usage but not current, no illicit drugs Family history: no pulmonary diseases Physical Exam Vital signs: temperature 36.7º C, heart rate 86 beats per minute ...

  7. ANALIZA IN KRITIČNA OCENA MARKETINŠKEGA SPLETA ZA BLAGOVNE ZNAMKE SLIM FIT

    OpenAIRE

    Runovec, Špela

    2011-01-01

    V diplomskem seminarju smo analizirali uporabo marketinškega spleta blagovne znamke Slim&Fit podjetja Perutnina Ptuj, d.d. Podjetje učinkovito uporablja vse štiri elemente marketinškega spleta, še posebej bi radi izpostavili izdelek, promocijske aktivnosti ter tržne poti. Kot smo že omenili ima blagovna znamka Slim&Fit zelo kvalitetno in bogato ponudbo mesnih izdelkov za vse, ki zaradi zdravstvenih težav ne smejo ali pa nočejo uživati veliko maščob. In lahko v tej liniji izdelkov najdejo mars...

  8. Magnetism in metal-organic capsules

    Energy Technology Data Exchange (ETDEWEB)

    Atwood, Jerry L.; Brechin, Euan K; Dalgarno, Scott J.; Inglis, Ross; Jones, Leigh F.; Mossine, Andrew; Paterson, Martin J.; Power, Nicholas P.; Teat, Simon J.

    2010-01-07

    Nickel and cobalt seamed metal-organic capsules have been isolated and studied using structural, magnetic and computational approaches. Antiferromagnetic exchange in the Ni capsule results from coordination environments enforced by the capsule framework.

  9. Impulse-driven Micromechanism Capsule

    Science.gov (United States)

    Ito, Takahiro; Ishimori, Shohei; Hayashi, Teru

    We have developed a traveling small capsule, which has a smooth outer surface and is driven by inertia force and friction force. Measuring only 7 mm in diameter and 12 mm in length, it is sufficiently small to be placed in the human gullet or intestines. The capsule contains a small magnet and a coil, and an electric pulse drives the magnet to move the capsule. We performed an experimental investigation on making our capsule travel on a plastic material, which has similar elasticity characteristics to the living body. We also showed that it can travel on the surface of a pig's intestine. Our capsule may be useful for medical treatments such as inspection, drug delivery and operation.

  10. Exposure to slim images in mass media: television commercials as reminders of restriction in restrained eaters

    NARCIS (Netherlands)

    D.J. Anschutz; T. van Strien; R.C. Engels

    2011-01-01

    Objective: The aim of the present study was to explore the effects of exposure to slim images and diet-related products in commercials on actual food intake in relation to dietary restraint. Design: An experimental design was used, in which food intake was measured in 124 female students who watched

  11. Phase 2 Reese River Geothermal Project Slim Well 56-4 Drilling and Testing

    Energy Technology Data Exchange (ETDEWEB)

    Henkle, William R.; Ronne, Joel

    2008-06-15

    This report covers the drilling and testing of the slim well 56-4 at the Reese River Geothermal Project in Lander County, Nevada. This well was partially funded through a GRED III Cooperative Funding Agreement # DE-FC36-04GO14344, from USDOE.

  12. Study on lifestyle-intervention and impaired glucose tolerance Maastricht (SLIM) : design and screening results

    NARCIS (Netherlands)

    Mensink, M; Corpeleijn, E; Feskens, EJM; Kruijshoop, M; Saris, WHM; de Bruin, TWA; Blaak, EE

    2003-01-01

    The study on lifestyle-intervention and impaired glucose tolerance Maastricht (SLIM) is a 3 years randomised clinical trial designed to evaluate the effect of a combined diet and physical activity intervention program on glucose tolerance in a Dutch population at increased risk for developing type 2

  13. Interpolis SlimOpWeg-programma : de AutoModus-app : samenvatting onderzoeksresultaten.

    NARCIS (Netherlands)

    2016-01-01

    Interpolis heeft in het kader van het SlimOpWeg-programma een app voor de smartphone laten ontwikkelen. Het doel van deze ‘AutoModus-app’ is om jongeren te helpen hun smart phonegebruik in de auto te verminderen. Afleiding door mobiel telefoongebruik vormt namelijk een groot verkeers veiligheidsprob

  14. Quantitative measurements in capsule endoscopy.

    Science.gov (United States)

    Keuchel, M; Kurniawan, N; Baltes, P; Bandorski, D; Koulaouzidis, A

    2015-10-01

    This review summarizes several approaches for quantitative measurement in capsule endoscopy. Video capsule endoscopy (VCE) typically provides wireless imaging of small bowel. Currently, a variety of quantitative measurements are implemented in commercially available hardware/software. The majority is proprietary and hence undisclosed algorithms. Measurement of amount of luminal contamination allows calculating scores from whole VCE studies. Other scores express the severity of small bowel lesions in Crohn׳s disease or the degree of villous atrophy in celiac disease. Image processing with numerous algorithms of textural and color feature extraction is further in the research focuses for automated image analysis. These tools aim to select single images with relevant lesions as blood, ulcers, polyps and tumors or to omit images showing only luminal contamination. Analysis of motility pattern, size measurement and determination of capsule localization are additional topics. Non-visual wireless capsules transmitting data acquired with specific sensors from the gastrointestinal (GI) tract are available for clinical routine. This includes pH measurement in the esophagus for the diagnosis of acid gastro-esophageal reflux. A wireless motility capsule provides GI motility analysis on the basis of pH, pressure, and temperature measurement. Electromagnetically tracking of another motility capsule allows visualization of motility. However, measurement of substances by GI capsules is of great interest but still at an early stage of development. PMID:26299419

  15. 芪白平肺胶囊药材挥发油β-环糊精包合物的制备及其表征%Preparation and Characterization of β-cyclodextrin Inclusion Compound of Volatile Oils from Traditional Chinese Medicinal Materials in Qibai Pingfei Capsules

    Institute of Scientific and Technical Information of China (English)

    陈娟; 李泽庚; 孟楣; 韩燕全; 高家荣

    2011-01-01

    Objective To prepare β-cyclodextrin (β-CD) inclusion compound of volatile oils from traditional Chinese medicinal materials in Qibai Pingfei Capsules, and to identify its characterization. Methods An orthogonal design was carried out to optimize the preparation of β-CD inclusion compound of volatile oils from traditional Chinese medicinal materials in Qibai Pingfei Capsules. The inclusion compound was identified by thin layer chromatography, differential scanning calorimetry, and X-ray powder diffractometry.Results The optimum conditions were obtained as follows: the ratio of oils to β-CD was 1:8(ml/g) , the temperature of inclusion was 50℃, the inclusion time was 2 h. The main compositions of volatile oils in the inclusion compound did not change significantly. The difference between the inclusion and physical mixtures in the curve was significant. Conclusion The optimized process is simple and reasonable. A stable inclusion compound of volatile oils and β-CD is formed.%目的 制备芪白平肺胶囊药材挥发油-β-环糊精(β-cyclodextrin, β-CD)包合物,并考察其表征.方法 采用正交试验法,优选芪白平肺胶囊药材中挥发油-β-CD包合物的制备工艺,采用薄层色谱法、差示扫描量热法、X射线粉末衍射法对包合物进行物相鉴定.结果 最佳包合工艺为:挥发油与β-CD的投料比为1∶8(ml/g),温度为50 ℃,包合时间为2 h.混合挥发油包合后,成分未见明显改变,包合物与β-CD物理混合物的图谱有显著性差异.结论 优选的包合工艺合理、简便易行,挥发油与β-CD形成稳定的包合物.

  16. Status of irradiation capsule design

    International Nuclear Information System (INIS)

    For the irradiation test after the restart of JMTR, further precise temperature control and temperature prediction are required. In the design of irradiation capsule, particularly sophisticated irradiation temperature prediction and evaluation are urged. Under such circumstance, among the conventional design techniques of irradiation capsule, the authors reviewed the evaluation method of irradiation temperature. In addition, for the improvement of use convenience, this study examined and improved FINAS/STAR code in order to adopt the new calculation code that enables a variety of analyses. In addition, the study on the common use of the components for radiation capsule enabled the shortening of design period. After the restart, the authors will apply this improved calculation code to the design of irradiation capsule. (A.O.)

  17. Adhesive capsulitis: a case report

    OpenAIRE

    Kazemi, Mohsen

    2000-01-01

    Adhesive capsulitis or frozen shoulder is an uncommon entity in athletes. However, it is a common cause of shoulder pain and disability in the general population. Although it is a self limiting ailment, its rather long, restrictive and painful course forces the affected person to seek treatment. Conservative management remains the mainstay treatment of adhesive capsulitis. This includes chiropractic manipulation of the shoulder, therapeutic modalities, mobilization, exercise, soft tissue ther...

  18. Deformability-based capsule sorting

    Science.gov (United States)

    Le Goff, Anne; Munier, Nadege; Maire, Pauline; Edwards-Levy, Florence; Salsac, Anne-Virginie

    2015-11-01

    Many microfluidic devices have been developed for cancer diagnosis applications, most of which relying on costly antibodies. Since some cancer cells display abnormal mechanical properties, new sorting tools based on mechanical sensing are of particular interest. We present a simple, passive pinched flow microfluidic system for capsule sorting. The device consists of a straight microchannel containing a cylindrical obstacle. Thanks to a flow-focusing module placed at the channel entrance, capsules arrive well-centered in the vicinity of the obstacle. Pure size-sorting can be achieved at low shear rate. When increasing the shear rate, capsules are deformed in the narrow space between the pillar and the wall. The softer the capsule, the more tightly it wraps around the obstacle. After the obstacle, streamlines diverge, allowing for the separation between soft capsules, that follow central streamlines, and stiff capsules, that drift away from the obstacle with a wider angle. This proves that we have developed a flexible multipurpose sorting microsystem based on a simple design.

  19. Evaluation of seismic performance and effectiveness of multiple slim-type damper system for seismic response control of building structures.

    Science.gov (United States)

    Kim, David; Sung, Eun Hee; Park, Kwan-Soon; Park, Jaegyun

    2014-01-01

    This paper presents the evaluation of seismic performance and cost-effectiveness of a multiple slim-type damper system developed for the vibration control of earthquake excited buildings. The multiple slim-type damper (MSD) that consists of several small slim-type dampers and linkage units can control damping capacity easily by changing the number of small dampers. To evaluate the performance of the MSD, dynamic loading tests are performed with three slim-type dampers manufactured at a real scale. Numerical simulations are also carried out by nonlinear time history analysis with a ten-story earthquake excited building structure. The seismic performance and cost-effectiveness of the MSD system are investigated according to the various installation configurations of the MSD system. From the results of numerical simulation and cost-effectiveness evaluation, it is shown that combinations of the MSD systems can effectively improve the seismic performance of earthquake excited building structures. PMID:25301387

  20. Summary Report for Capsule Dry Storage Project

    Energy Technology Data Exchange (ETDEWEB)

    JOSEPHSON, W S

    2003-09-04

    There are 1.936 cesium (Cs) and strontium (Sr) capsules stored in pools at the Waste Encapsulation and Storage Facility (WESF). These capsules will be moved to dry storage on the Hanford Site as an interim measure to reduce risk. The Cs/Sr Capsule Dry Storage Project (CDSP) is conducted under the assumption the capsules will eventually be moved to the repository at Yucca Mountain, and the design criteria include requirements that will facilitate acceptance at the repository. The storage system must also permit retrieval of capsules in the event vitrification of the capsule contents is pursued. A cut away drawing of a typical cesium chloride (CsCI) capsule and the capsule property and geometry information are provided in Figure 1.1. Strontium fluoride (SrF{sub 2}) capsules are similar in design to CsCl capsules. Further details of capsule design, current state, and reference information are given later in this report and its references. Capsule production and life history is covered in WMP-16938, Capsule Characterization Report for Capsule Dry Storage Project, and is briefly summarized in Section 5.2 of this report.

  1. DC-Link Compensation Method for Slim DC Link Drives Fed by Soft Grid

    DEFF Research Database (Denmark)

    Mathe, Laszlo; Rosendahl Andersen, Henrik; Lazar, Radu;

    2010-01-01

    Slim DC-link PWM (AC) drives for lowperformance applications are emerging on the market. Such drives equipped with a small DC-link capacitance exhibit instability tendencies, if installed on a soft line, giving a degraded performance. The total harmonic distortion (THD) and the partially weighted...... harmonic distortion (PWHD) of the line current are degraded, if resonance between the line impedance and the DC-link capacitance occurs. Likewise, the motor performance is affected negatively giving extra torque ripple, vibration and acoustic-noise emission. This paper proposes a novel DC-link compensation...... method, which ensures the stability of the slim DC-link on a soft grid. The proposed compensation method may be used for open- and closedloop control schemes, requiring a small overhead in the digital implementation....

  2. Simulation of density curve for slim borehole using the Monte Carlo code MCNPX

    International Nuclear Information System (INIS)

    Borehole logging for formation density has been an important geophysical measurement in oil industry. For calibration of the Gamma Ray nuclear logging tool, numerous rock models of different lithology and densities are necessary. However, the full success of this calibration process is determined by a reliable benchmark, where the complete and precise chemical composition of the standards is necessary. Simulations using the Monte Carlo MCNP have been widely employed in well logging application once it serves as a low-cost substitute for experimental test pits, as well as a means for obtaining data that are difficult to obtain experimentally. Considering this, the purpose of this work is to use the code MCNP to obtain density curves for slim boreholes using Gamma Ray logging tools. For this, a Slim Density Gamma Probe, named TRISONDR, and a 100 mCi Cs-137 gamma source has been modeled with the new version of MCNP code MCNPX. (author)

  3. Things to Know about Carlos Slim%首富七大轶事

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    He's the first world's richest man from a developing nation. In Mexico, Slim is known as"Mr. Monopoly" The Wall Street Journal once quipped that "it's hard to spend a day in Mexico and not put money in Slim's pocket."%他是来自发展中国家的第一位世界首富。 在墨西哥,斯翻姆被称为“垄断先生”。 《华尔街日报》曾调侃道:“如果在墨西哥呆一天而不想让钞票流进斯利姆的口袋,那几乎是不可能的。”

  4. Simulation of density curve for slim borehole using the Monte Carlo code MCNPX

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Edmilson Monteiro de; Silva, Ademir Xavier da; Lopes, Ricardo Tadeu, E-mail: emonteiro@nuclear.ufrj.b, E-mail: ademir@nuclear.ufrj.b, E-mail: ricardo@lin.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear; Correa, Samanda Cristine Arruda, E-mail: scorrea@nuclear.ufrj.b [Centro Universitario Estadual da Zona Oeste (CCMAT/UEZO), Rio de Janeiro, RJ (Brazil); Lima, Inaya C.B., E-mail: inaya@lin.ufrj.b [Universidade Estadual do Rio de Janeiro (IPRJ/UERJ) Nova Friburgo, Rio de Janeiro, RJ (Brazil). Instituto Politecnico do Rio de Janeiro; Rocha, Paula L.F., E-mail: ferrucio@acd.ufrj.b [Universidade Federal do Rio de Janeiro (UFRJ) RJ (Brazil). Dept. de Geologia

    2010-07-01

    Borehole logging for formation density has been an important geophysical measurement in oil industry. For calibration of the Gamma Ray nuclear logging tool, numerous rock models of different lithology and densities are necessary. However, the full success of this calibration process is determined by a reliable benchmark, where the complete and precise chemical composition of the standards is necessary. Simulations using the Monte Carlo MCNP have been widely employed in well logging application once it serves as a low-cost substitute for experimental test pits, as well as a means for obtaining data that are difficult to obtain experimentally. Considering this, the purpose of this work is to use the code MCNP to obtain density curves for slim boreholes using Gamma Ray logging tools. For this, a Slim Density Gamma Probe, named TRISOND{sup R}, and a 100 mCi Cs-137 gamma source has been modeled with the new version of MCNP code MCNPX. (author)

  5. Developing standardized connection analysis techniques for slim hole core rod designs

    International Nuclear Information System (INIS)

    Slim hole core rod design remains essentially in the proprietary domain. API standardization provides the ability to perform engineering analyses and dimensional inspections through the use of documents, ie: Specifications, Bulletins, and Recommended Practices. In order to provide similar engineering capability for non-API slim hole connections, this paper develops the initial phase of what may evolve into an engineering tool to provide at least an indication of relative serviceability between two connection styles for a given application. The starting point for this process will look at bending strength ratios and connection strength calculations. Since empirical data are yet needed to verify the approaches proposed in this paper, it is recognized that the alternatives presented here are only a first step to developing useful rules of thumb which may lead to later standardization

  6. Anti-inflammatory Effects of Xuezhikang Capsule (血脂康胶囊)

    Institute of Scientific and Technical Information of China (English)

    ZHAO Shui-ping

    2006-01-01

    @@ It has been proved thatXuezhikang Capsule ( XZK,血脂康胶囊), a Chinese red-yeast rice extract, contains multiple natural statins (8 monacolins) and other components, which could significantly reduce the total cholesterol (TC) and LDL-cholesterol concentrations in blood.

  7. Microwave left-handed composite material made of slim ferrite rods and metallic wires

    International Nuclear Information System (INIS)

    This paper reports on experimental study of the microwave properties of a composite material consisting of ferrite and copper wires. It finds that the slim ferrite rods can modify the magnetic field distribution through their anisotropy, so that the ferrite's negative influence on the copper wires' plasma will be reduced. Left-handed properties are observed even in the specimen with close stuck ferrite rods and copper wires. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  8. Epidemics of Abundance: Overeating and Slimming in the USA and Britain since the 1950s.

    OpenAIRE

    Offer, Avner

    1998-01-01

    Body weight has risen in defiance of health and appearance norms. The social epidemics of overeating and slimming were driven by market forces and the psychology of eating: restrained eating is easily disinhibited by stress. For men, the rise in body weight was associated with the decline of family eating and exposure to greater food variety. For women, the ‘cult of slimming’ was associated with mating competition, driven initially by adverse sex ratios. Food abundance made a m...

  9. Epidemics of Abundance: Overeating and Slimming in the USA and Britain since the 1950s.

    OpenAIRE

    Offer, Avner

    1998-01-01

    Body weight has risen in defiance of health and appearance norms. The social epidemics of overeating and slimming were driven by market forces and the psychology of eating: restrained eating is easily disinhibited by stress. For men, the rise in body weight was associated with the decline of family eating and exposure to greater food variety. For women, the ‘cult of slimming’ was associated with mating competition, driven initially by adverse sex ratios. Food abundance made a mockery of the r...

  10. SlimQuick™ - associated hepatotoxicity in a woman with alpha-1 antitrypsin heterozygosity

    OpenAIRE

    Weinstein, Douglas H; Twaddell, William S.; Raufman, Jean-Pierre; Philosophe, Benjamin; Mindikoglu, Ayse L

    2012-01-01

    Green tea (Camellia sinensis)-associated hepatotoxicity is reported. However, the presence of alpha-1 antitrypsin MZ phenotype as a predisposing factor to green tea-associated drug-induced liver injury (DILI) is unknown. A previously healthy woman with alpha-1 antitrypsin MZ phenotype who took SlimQuick™, an herbal supplement containing green tea extract, developed severe hepatotoxicity requiring corticosteroid treatment. Green tea-associated hepatotoxicity is reviewed and alpha-1 antitrypsin...

  11. Recent results on 3D double sided detectors with slim edges

    Energy Technology Data Exchange (ETDEWEB)

    Pellegrini, G., E-mail: giulio.pellegrini@csic.es [Centro Nacional de Microelectrónica, CNM-IMB (CSIC), Barcelona 08193 (Spain); Baselga, M. [Centro Nacional de Microelectrónica, CNM-IMB (CSIC), Barcelona 08193 (Spain); Christophersen, M. [U.S. Naval Research Laboratory, Code 7654, Washington, DC 20375 (United States); Ely, S.; Fadeyev, V. [Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA 95064 (United States); Fleta, C. [Centro Nacional de Microelectrónica, CNM-IMB (CSIC), Barcelona 08193 (Spain); Gimenez, A.; Grinstein, S.; Lopez, I. [ICREA and Institut de Física d' Altes Energies (IFAE), Barcelona 08193 (Spain); Lozano, M. [Centro Nacional de Microelectrónica, CNM-IMB (CSIC), Barcelona 08193 (Spain); Micelli, A. [ICREA and Institut de Física d' Altes Energies (IFAE), Barcelona 08193 (Spain); Phlips, B.F. [U.S. Naval Research Laboratory, Code 7654, Washington, DC 20375 (United States); Quirion, D. [Centro Nacional de Microelectrónica, CNM-IMB (CSIC), Barcelona 08193 (Spain); Sadrozinski, H.F.-W. [Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA 95064 (United States); Tsiskaridze, S. [ICREA and Institut de Física d' Altes Energies (IFAE), Barcelona 08193 (Spain)

    2013-12-11

    This paper reports on the first characterization of double sided 3D silicon radiation pixel detectors with slim edges. These detectors consist of a three-dimensional array of electrodes that penetrate into the detector bulk with the anode and cathode electrodes etched from opposite sides of the substrate. Different detectors were post-processed using the scribe-cleave-passivate (SCP) technology to make “slim edge” sensors. These sensors have only a minimal amount of inactive peripheral region, for the benefit of the construction of large-area tracker and imaging systems. The target application for this work is the use of 3D slim edge detectors for the ATLAS Forward Physics (AFP) CERN Project, where pixel detectors for position resolution and timing detectors for removal of pile up protons, will be placed as close as possible to the beam to detect diffractive protons at 220 m on either side of the ATLAS interaction point. For this reason the silicon areas should feature the narrowest possible insensitive zone on the sensor edge closest to the beam and withstand high nonuniform irradiation fluences.

  12. Triggered Release from Polymer Capsules

    Energy Technology Data Exchange (ETDEWEB)

    Esser-Kahn, Aaron P. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Odom, Susan A. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Sottos, Nancy R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Materials Science and Engineering; White, Scott R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Aerospace Engineering; Moore, Jeffrey S. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry

    2011-07-06

    Stimuli-responsive capsules are of interest in drug delivery, fragrance release, food preservation, and self-healing materials. Many methods are used to trigger the release of encapsulated contents. Here we highlight mechanisms for the controlled release of encapsulated cargo that utilize chemical reactions occurring in solid polymeric shell walls. Triggering mechanisms responsible for covalent bond cleavage that result in the release of capsule contents include chemical, biological, light, thermal, magnetic, and electrical stimuli. We present methods for encapsulation and release, triggering methods, and mechanisms and conclude with our opinions on interesting obstacles for chemically induced activation with relevance for controlled release.

  13. Polyelectrolyte Multilayer Capsules for Medical Applications

    OpenAIRE

    Nazarenus, Moritz

    2015-01-01

    This thesis deals with the application of polymer capsules for diagnostic and therapeutic purposes in mammalian cells. The capsules comprise a multilayer shell of oppositely charged polyelectrolytes surrounding a cavity and have a size of two to five microns. Concerning diagnostics, capsules were produced to monitor the dynamics of the lysosomal pH in cancer cells. The cavities of the capsules were filled with a fluoresce...

  14. 中药天癸胶囊治疗多囊卵巢综合征的随机对照疗效观察%Efficacy of Chinese patent medicine Tian Gui Capsule in patients with polycystic ovary syndrome:a randomized controlled trial

    Institute of Scientific and Technical Information of China (English)

    郭素璇; 王文君; 归绥琪

    2011-01-01

    Background:Polycystic ovary syndrome (PCOS) is a complex hormonal disorder and one of the most common reproductive endocrinology abnormalities in women.Recently,many studies have been conducted assessing Chinese herbal medicine as an alternative treatment for women with PCOS,it is,therefore,worthwhile to analyze and observe the curative effects of traditional Chinese medicine treatment in PCOS.Objective:To evaluate the efficacy of the Chinese patent medicine Tian Gui Capsule,in women with PCOS and compare its effects with metformin and ethinyl estradiol plus cyproterone acetate (Diane-35).Design,setting,participants and intervention:A total of 47 PCOS outpatients from the Obstetrics and Gynecology Hospital of Fudan University were randomly divided into 3 groups.Patients in group A (n =19) were given Tian Gui Capsule,patients in group B (n =17) were given metformin,and patients in group C (n=11) were given Diane-35.The 3 groups of patients were treated for 3 months.Main outcome measures:Serum testosterone (T),sex hormone binding globulin (SHBG) and dehydroepiandrosterone sulfate (DHEA-S) levels,free androgen index (FAI),fasting blood glucose (FPG),fasting insulin (FINS),homeostasis model assessment of insulin resistance (HOMA-IR),insulin sensitive index (ISI) and left and right ovary volumes of the 3 groups were evaluated before and after treatment.Results:After 3 months of treatment,when compared with before treatment data,group A patients showed decreased serum T and SHBG levels,FAI,FINS,and left and right ovary volumes (P<0.05),and increased serum DHEA-S (P<0.05),while the FPG level showed no significant change.Although the level of serum T and FINS among the 3 groups after the treatment were similar,group A demonstrated better results than group B in reducing the FAI and increasing the serum SHBG,but less significant results than group C besides,group B was the only group showed improved insulin sensitivity.Although the level of FPG of the 3 groups after

  15. Photon Production Within Storage Capsules

    CERN Document Server

    Rittmann, P D

    2003-01-01

    This report provides tables and electronic worksheets that list the photon production rate within SrF2 and CsC1 storage capsules, particularly the continuous spectrum of bremsstrahlung photons from the slowing down of the emitted electrons (BREMCALC).

  16. Barrier function of the posterior capsule

    International Nuclear Information System (INIS)

    The permeability of the rabbit lens and human cataractous lens posterior capsule to epinephrine and trypan blue and the absorption of ultraviolet and visible light through the posterior capsule were studied in vitro. The posterior capsule served as a barrier to large nonelectrolytes or negative electrolytes other than trypan blue, but it did not impede epinephrine, ultraviolet or visible light

  17. 高脂饮食对阿雷地平及其活性代谢产物的人体药动学、药效学特征及安全性的影响%Effects of High-Fat Meal on the Pharmacokinetic and Pharmacodynamic Properties and Safety Profile of Aranidipine Enteric-Coated Capsule in Healthy Chinese Subjects

    Institute of Scientific and Technical Information of China (English)

    杜海燕; 闫秀娟; 贾小欣; 周子杰; 吴伟; 所伟; 赵桂平; 刘文芳; 杨跃汉; 李静; 杨克旭; 林阳; 吴学思; 揭秉章; 方珊娟

    2011-01-01

    目的 评价高脂饮食对口服阿雷地平肠溶胶囊后健康中国人体内阿雷地平(AR)及其活性代谢产物羟基阿雷地平(ARM1)的药动学(PK)、药效学(PD)的影响,并评价高脂饮食对该制剂的安全性的影响.方法 采用随机、开放、自身交叉试验设计,12名健康受试者(男女各半)分两个阶段分别进行空腹和高脂餐后单次口服AR肠溶胶囊10 mg的PK试验,两次给药间隔7 d.每次给药前及给药后36 h内采集PK血样,采用液相色谱-串联质谱联用法(LC-MS/MS)测定健康受试者给药后血浆中AR及AR-M1的浓度.采用DAS2.1.1软件计算AR和AR-M1的主要PK参数(AUC0-t、AUC0-∞、ρmax、tmax、t1/2、Ke、CL/F、Vd/F等).给药前及给药后36 h内分别测量收缩压(SBP)、舒张压(DBP)及心率作为药效学指标.整个试验过程中进行全面安全性评估.结果 空腹和高脂餐后单次口服AR肠溶胶囊10 mg后,AR的AUC0-t、AUC0-∞、和tmax有显著性差异(P0.05).空腹和高脂餐后单次口服 AR,受试者 DBP、SBP发生不同程度降低,其中在给药后8 h两组受试者DBP均显著低于基线值(P0.05).结论 高脂饮食导致AR的吸收出现延迟现象,吸收程度显著增加;AR-M1的体内生成延迟;血压、心率无显著变化;本研究制剂安全性较好,试验过程无严重不良事件发生.综合考虑,临床应用不需调整用法用量,但应充分考虑病人的饮食习惯,建议空腹给药及清淡饮食.%OBJECTIVE To assess the effects of high-fat meal on the pharmacokinetic(PK) and pharmacodynamic(PD) properties and safety profile of aranidipine (AR) and its active metabolite, hydroxyl-aranidipine ( AR-M1 ), in health Chinese subjects.METHODS One single-dose, open-label, randomized, crossover study of oral aranidipine enteric-coated capsule was conducted in healthy Chinese subjects.Twelve healthy nonsmoking subjects(6 males, 6 females) aged from 18 to 45 years were orally administrated aranidipine enteric

  18. Bioequivalence of paracetamol and dihydrocodeine tatrate capsules in Chinese healthy volunteers%氨酚双氢可待因胶囊在健康人体的生物等效性

    Institute of Scientific and Technical Information of China (English)

    邱相君; 王淑英; 刘涛; 袁世英; 刘心霞; 陈汇

    2011-01-01

    Objective To study the bioequivalence of paracetamol and dihydrocodeine tartrate capsules in healthy volunteers.Methods A single oral dose of tested and reference formulation were given to 20 healthy volunteers in a randomised crossover study.The concentrations of acetaminophen and dihydrocodeine in plasma were determined by HPLC, respectively.The pharmacokinetic parameters were calculated and the bioavailability and bioequivalence of acetaminophen and dihydrocodeine were evaluated by DAS program.Results After a single dose, the pharmacokinetic parameters for acetaminophen were as follows: Cmax were (9.06 ±2.05) and (9.15 ±2.50) mg· L-1; AUC0-14were (34.46 ±7.49) and (35.91 ±7.01) mg · h · L-1; AUC0-∞ were (35.66 ±7.86) and (37.24 ± 7.56) mg· h · L- 1 for tested and reference formulation, respectively.The relative bioavailability was (97.17 ± 19.09)%The pharmacokinetic parameters for dihydrocodeine were as follows:Cmax were (61.84 ±9.84) and (58.33 ±6.79) μg · L-1; AUC0-14 were (289.23 ±31.30) and (281.56 ±25.91) μg · h · L-1; AUC0-∞ were (304.83 ±32.95) and (298.45 ±29.15) μg · h · L-1 for tested and reference formulation, respectively.The relative bioavailability was ( 103.58 ± 15.09) %.Conclusion The results of the statistic analysis showed that the two formulations were bioequivalence.%目的 研究氨酚双氢可待因胶囊(解热镇痛药)在健康人体的生物等效性.方法 健康志愿者 20 名随机双交叉分别单剂量口服氨酚双氢可待因胶囊(试验制剂)和氨酚双氢可待因片(参比制剂);分别于服药后 14 h 内,多点抽取静脉血;用高效液相色谱法分别测定血浆中对乙酰氨基酚和双氢可待因的浓度;用 DAS 程序计算相对生物利用度并评价 2 种制剂生物等效性.结果 单剂量口服氨酚双氢可待因胶囊和片剂后,血浆中对乙酰氨基酚的 Cmax 分别为(9.06±2.05),(9.15±2.50)mg·L-1;AUC0-14分别为(34.46±7.49),(35.91±7.01)mg·h·L-1

  19. Testing of capsules used in radiography cameras

    International Nuclear Information System (INIS)

    The C-182 non-radioactive (dummy) radiography capsules manufactured by Atomic Energy of Canada Limited were mechanically tested by performing a prescribed number of cycles under preset conditions in a Model 100-3 Pneumat- A-Ray radiography camera. The capsules were observed throughout the cycling trials and tested for changes in dimension, weight, and leakage. After completion of the prescribed cycling trials each capsule was further tested for potential leakage by dye penetrant examination, sectioned at the equator and each half tested by dye penetrant examination, then sectioned again longitudinally and metallurgically examined. The results indicate that the capsules cycled under typical field conditions can become significantly deformed, and that deformation is generally related to the number of cycles that the capsules undergo. The deformation occurs almost exclusively on the end of the capsule entering the camera first. When the headhose cushion is removed the deformation occurs on both ends of the capsule. The deformation is related only to the pneumatic operating mode of the camera and there was no evidence for deformation when the camera was used under pipeline mode of operation. The only leak observed in this series of tests was not related to the deformed end of the capsule, but rather to the weld end of the capsule when the non weld end of the capsule was deformed from entering the camera. The leak was shown by dye penetrant examination and by photomicrographs of the cross section of the affected capsule

  20. Effect of tian meng capsule treatment on serum TGA, TMA levels in patients with hashimoto's disease

    International Nuclear Information System (INIS)

    Objective: To study the effect of tian meng capsule treatment on the serum levels of TGA, TMA in patients with chronic lymphocytic thyroiditis (CLTD or Hashimoto's disease). Methods: Serum TGA and TMA levels were determined with RIA both before and after treatment for 3 months in (1) 30 patients treated with conventional drugs (2) 30 patients treated with conventional drugs plus tian meng capsule (a traditional chinese medicine preparation No.2, tid) and (3) once in 30 controls. Results: Before treatment,the serum TGA and TMA levels in all the patients were significantly, higher than those in controls. After 3 months' treatment, serum TGA and TMA levels in all the patients dropped, but the levels in the patients treated with additional tian meng capsule were significantly lower than those in patients without tian meng capsule treatment. Moreover, 76.7% of the patients with tian meng capsule treatment had their serum TGA and TMA levels decreased over 30%, four patients even had the serum levels became normal. Conclusion: tian meng capsule treatment is very effective in lowering serum TGA and TMA levels in patients with Hashimoto's disease. (authors)

  1. Less Fat, Less Sugar and Scientific Slimming%减脂、减糖与科学瘦身

    Institute of Scientific and Technical Information of China (English)

    严铁宁; 蔡东

    2012-01-01

    Scientific slimming does not imply not eating anything, but it means rationally eating less fat and sugar, as well as gradually increasing athletic sports according to one's personal health. Scientific slimming takes sports-heating-effect seriously, which means sports can consume fat and increase expenditure of energy. In addition, scientific slimming requires optimized sleep in accordance with the regular pattern of human body's biological clock.%科学瘦身不等于不吃,是合理的减掉脂肪和糖类的摄入,同时视个人身体状况循序渐进的增加体育运动,重视运动生热效应,燃烧脂肪,增加能量消耗,还要按照人体生物钟的运行规律优化睡眠,休息好.

  2. A study of production/injection data from slim holes and production wells at the Oguni Geothermal Field, Japan

    Energy Technology Data Exchange (ETDEWEB)

    Garg, S.K.; Combs, J.; Abe, M.

    1996-03-01

    Production and injection data from slim holes and large-diameter wells at the Oguni Geothermal Field, Japan, were examined in an effort to establish relationships (1) between productivity of large-diameter wells and slim holes, (2) between injectivity and productivity indices and (3) between productivity index and borehole diameter. The production data from Oguni boreholes imply that the mass production from large-diameter wells may be estimated based on data from slim holes. Test data from both large- and small-diameter boreholes indicate that to first order the productivity and the injectivity indices are equal. Somewhat surprisingly, the productivity index was found to be a strong function of borehole diameter; the cause for this phenomenon is not understood at this time.

  3. ION MANIPULATIONS IN STRUCTURES FOR LOSSLESS ION MANIPULATIONS (SLIM): COMPUTATIONAL EVALUATION OF A 90o TURN AND A SWITCH

    Energy Technology Data Exchange (ETDEWEB)

    Garimella, Venkata BS; Ibrahim, Yehia M.; Webb, Ian K.; Ipsen, Andreas B.; Chen, Tsung-Chi; Tolmachev, Aleksey V.; Baker, Erin Shammel; Anderson, Gordon A.; Smith, Richard D.

    2015-08-19

    The process of redirecting ions through 90o turns and ‘tee’ switches utilizing Structures for Lossless Ion Manipulations (SLIM) was evaluated using theoretical and simulation methods at 4 Torr pressure. SIMION simulations were used to optimize and evaluate conditions for performing turns without loss of signal intensity or ion mobility resolving power. Fundamental considerations indicated that the “race track” effect during ion turns may incur only small losses to the ion mobility resolving power at 4 Torr pressure for the typical plume widths predicted in an optimized SLIM ‘tee’ switch design. The dynamic switching of ions into orthogonal channels was also evaluated using SIMION ion trajectory simulations, and achieved similar performance. Simulation results were in close agreement with experimental results and were used to refine SLIM designs and applied potentials for their use.

  4. Slim 198gold-grain implanter loaded with standard royal marsden 14-grain magazines

    International Nuclear Information System (INIS)

    We designed a slim gold-grain implanter with adaptable lengths to implant areas accessible only through long, narrow, examining instruments, such as a suspension laryngoscope. The implanter is loaded with the same 14-grain magazine designed for and supplied with the Royal Marsden gun. The simplicity of the loading mechanism with a minimum of moving parts makes the instrument practically trouble free. Although it is designed to be used along narrow examining instruments, it can also be used in any situation in which a permanent implant is required, for instance, prostatic cancer and pelvic recurrences in cancer of the uterine cervix previously treated by external and intracavitary irradiation

  5. Spatial Light Interference Microscopy (SLIM) using twisted-nematic liquid-crystal modulation

    OpenAIRE

    Nguyen, Tan H.; Popescu, Gabriel

    2013-01-01

    We report the use of a twisted nematic liquid-crystal spatial light modulator (TNLC-SLM) for quantitative phase imaging. The experimental setup is a new implementation of the SLIM principle, which is a phase shifting, white light method for quantitative phase imaging. The approach is based on switching between the phase and amplitude modulation modes of the SLM. Our system is able to deliver a 0.99 nm spatial and 1.33 nm temporal pathlength sensitivity while retaining the optical transverse r...

  6. SLIM: A multi-scale model of the land-sea continuum

    Science.gov (United States)

    De Maet, T.; Hanert, E.; Deleersnijder, E.; Fichefet, T.; Legat, V.; Remacle, J. F.; Soares Frazao, S.; Vanclooster, M.; Lambrechts, J.; König Beatty, C.; Bouillon, S.; de Brye, B.; Gourgue, O.; Kärnä, T.; Lietaer, O.; Pestiaux, A.; Slaoui, K.; Thomas, C.

    2012-04-01

    The hydrosphere is made up of a number media, such as the oceans, the shelf seas, the estuaries, the rivers, the land surface and ground water as well as the sea ice - which, for the sake of simplicity, is considered herein to be part of the hydrosphere. The processes taking place in these domains are vastly different in nature and are characterized by a wide range of space- and time-scales. The components of the hydrosphere interact with each other. For instance, the shallow marine and estuarine regions, though accounting for less than 1% of the volume of the oceans, have a biomass far from negligible as compared to that of the oceans, implying that they play a significant role in global biogeochemical cycles. This is one of the reasons why models are now needed that deal with most, if not all, of the components of the hydrospheric system. Numerical models of each of the components of the hydrosphere already exist. However, an integrated model of the whole hydrosphere has yet to be developed. Building such a model is a daunting task, requiring the development of multi-scale/physics simulation tools. Numerical methods for dealing with multi-scale problems are developing rapidly. Unstructured meshes offer an almost infinite geometrical flexibility, allowing the space resolution to be increased when and where necessary. In addition, time steppings for dealing with a wide spectrum of timescales while retaining a high order of accuracy have been developed over recent years (e.g. multi-rate schemes). The Discontinuous Galerkin Finite Element (DGFE) framework SLIM is at his third implementation. It has been build on the GMSH code (http://geuz.org/gmsh), which a state-of-the-art open-source meshing tool. This allows the use of the same definitions and easy interactions between the mesher and the model. Moreover, this provides the same user interface for meshing and visualizing results. It also enables the use of the most recent advances in mesh generation, as GMSH has a

  7. Family love time capsule preview

    CERN Document Server

    Musgrave, Jim

    2015-01-01

    Create your own family time capsule online using EMRE Publishing's ePub3 Creator Studio. With our storage plans, your family videos, music playlists and mysteries can be preserved for coming generations to add to, embellish, and communicate using our Family Forum inside the Embellisher eReader for multimedia ""enhanced"" eBooks. Just like the ""American Sniper"" enhanced eBook, you can pay tribute to your fallen heroes and other family members who have distinguished themselves in life.

  8. Classifying genes to the correct Gene Ontology Slim term in Saccharomyces cerevisiae using neighbouring genes with classification learning

    Directory of Open Access Journals (Sweden)

    Tsatsoulis Costas

    2010-05-01

    Full Text Available Abstract Background There is increasing evidence that gene location and surrounding genes influence the functionality of genes in the eukaryotic genome. Knowing the Gene Ontology Slim terms associated with a gene gives us insight into a gene's functionality by informing us how its gene product behaves in a cellular context using three different ontologies: molecular function, biological process, and cellular component. In this study, we analyzed if we could classify a gene in Saccharomyces cerevisiae to its correct Gene Ontology Slim term using information about its location in the genome and information from its nearest-neighbouring genes using classification learning. Results We performed experiments to establish that the MultiBoostAB algorithm using the J48 classifier could correctly classify Gene Ontology Slim terms of a gene given information regarding the gene's location and information from its nearest-neighbouring genes for training. Different neighbourhood sizes were examined to determine how many nearest neighbours should be included around each gene to provide better classification rules. Our results show that by just incorporating neighbour information from each gene's two-nearest neighbours, the percentage of correctly classified genes to their correct Gene Ontology Slim term for each ontology reaches over 80% with high accuracy (reflected in F-measures over 0.80 of the classification rules produced. Conclusions We confirmed that in classifying genes to their correct Gene Ontology Slim term, the inclusion of neighbour information from those genes is beneficial. Knowing the location of a gene and the Gene Ontology Slim information from neighbouring genes gives us insight into that gene's functionality. This benefit is seen by just including information from a gene's two-nearest neighbouring genes.

  9. Capsule endoscopy: The road ahead.

    Science.gov (United States)

    Singeap, Ana-Maria; Stanciu, Carol; Trifan, Anca

    2016-01-01

    Since its introduction into clinical practice 15 years ago, capsule endoscopy (CE) has become the first-line investigation procedure in some small bowel pathologies, and more recently, dedicated esophageal and colon CE have expanded the fields of application to include the upper and lower gastrointestinal disorders. During this time, CE has become increasingly popular among gastroenterologists, with more than 2 million capsule examinations performed worldwide, and nearly 3000 PubMed-listed studies on its different aspects published. This huge interest in CE may be explained by its non-invasive nature, patient comfort, safety, and access to anatomical regions unattainable via conventional endoscopy. However, CE has several limitations which impede its wider clinical applications, including the lack of therapeutic capabilities, inability to obtain biopsies and control its locomotion. Several research groups are currently working to overcome these limitations, while novel devices able to control capsule movement, obtain high quality images, insufflate the gut lumen, perform chromoendoscopy, biopsy of suspect lesions, or even deliver targeted drugs directly to specific sites are under development. Overlooking current limitations, especially as some of them have already been successfully surmounted, and based on the tremendous progress in technology, it is expected that, by the end of next 15 years, CE able to perform both diagnostic and therapeutic procedures will remain the major form of digestive endoscopy. This review summarizes the literature that prognosticates about the future developments of CE. PMID:26755883

  10. Uneasy money: the Instituto Carlos Slim de la Salud, tobacco philanthropy and conflict of interest in global health

    OpenAIRE

    Burch, Tiffany; Wander, Nathaniel; Collin, Jeff

    2010-01-01

    In May 2007, the Instituto Carso de la Salud—now Instituto Carlos Slim de la Salud (ICSS)—was endowed with US$500 million to focus on priority health issues in Latin America, notably issues of ‘globalisation and non-communicable diseases’. ICSS was soon criticised, however, on the grounds that its funding was derived from tobacco industry profits and that its founder Carlos Slim Hélu remained an active industry principal. Collaboration with ICSS was said to run counter to the WHO Framework Co...

  11. Stability of slim accretion discs - effects of central mass and viscosity

    International Nuclear Information System (INIS)

    Slim accretion discs have a total luminosity of the order L/LE = m ∝ 1, where LE is the Eddington luminosity and m = M/Mc, where Mc is a critical accretion rate, related to the Teddington one. The local stability properties of such discs are examined, in the three-dimensional parameter space spanned by the (α, μ, m) axes, where α and μ are two viscosity parameters, and m = M/Msun the central mass. We suggest that various types of observed quasi-periodic behaviour may be connected with slim disc instabilities. If this turns out to be correct, the so-called normal and horizontal branch oscillations could be due to unstable thermal and acoustic modes, respectively. It is subsequently shown that some of the observed short-term (quasi-periodic) variability in active galactic nuclei may also originate from short-wavelength acoustic modes in the innermost region of the disc. Consequently, observational characteristics, in connection with stability theory, may yield estimates of basic accretion parameters. In the case of the Seyfert galaxy NGC 6814, this process seems to favour (α, μ, m, m) ≅ (0.5, 0, 106, 10-2). We finally conclude that this line of work may provide additional evidence for both accretion discs and black holes, in various compact sources. (orig.)

  12. Effect of Wujia Shenghua capsule on uterine bleeding following medically-induced incomplete abortion in rats during early pregnancy

    OpenAIRE

    Liu, Haiyang; Ma, Wei; Liu, Qi; Wang, Fashan; Cao, Ling; Li, TieNan; Zhang, Ning; Geng, Fang

    2015-01-01

    The Wujia Shenghua capsule (WSC) is derived from Sheng-Hua-Tang, a well-known traditional Chinese medicine compound prescription that has been widely applied during the postpartum period in Chinese communities for a number of years. The aim of the present study was to investigate the effect of WSC on uterine bleeding following medically-induced incomplete abortion in rats during early pregnancy. Incomplete abortions were induced in Wistar rats during early pregnancy using mifepristone combine...

  13. Asymmetric Membrane Osmotic Capsules for Terbutaline Sulphate

    OpenAIRE

    Gobade, N. G.; Marina Koland; K H Harish

    2012-01-01

    The aim of the present study was to design an asymmetric membrane capsule, an osmotic pump-based drug delivery system of ethyl cellulose for controlled release of terbutaline sulphate. asymmetric membrane capsules contains pore-forming water soluble additive, sorbitol in different concentrations in the capsule shell membrane, which after coming in contact with water, dissolves, resulting in an in situ formation of a microporous structure. The terbutaline sulphate is a β-adrenoreceptor agonist...

  14. Status of the material capsule irradiation and the development of the new capsule technology in HANARO

    International Nuclear Information System (INIS)

    A material capsule system including a main capsule, fixing, control, cutting, and transport systems was developed for an irradiation test of non-fissile materials in HANARO. 14 irradiation capsules (12 instrumented and 2 non-instrumented capsules) have been designed, fabricated and successfully irradiated in the HANARO CT and IR test holes since 1995. The capsules were mainly designed for an irradiation of the RPV (Reactor Pressure Vessel), reactor core materials, and Zr-based alloys. Most capsules were made for KAERI material research projects, but 5 capsules were made as a part of national projects for the promotion of the HANARO utilization for universities. Based on the accumulated irradiation experience and the user's sophisticated requirements, development of new instrumented capsule technologies for a more precise control of the irradiation temperature and fluence of a specimen irrespective of the reactor operation has been performed in HANARO. (author)

  15. Diagnostic and therapeutic radio pharmaceutical capsules

    International Nuclear Information System (INIS)

    An improved pharmaceutical radioactive capsule consisting of a non-toxic, water soluble material adapted to being ingested and rapidly disintegrating on contact with fluids of the gastro-intestinal tract is described. Each capsule is provided with filler material supporting a pharmaceutically useful radioactive compound absorbable from the gastro-intestinal tract. The capsule is preferably of gelatin, methyl cellulose or polyvinyl alcohol and the filler is a polyethylene glycol. The radioactive compound may be iodine e.g. sodium radioiodide I-131 or 123. The capsule may also contain a reducing agent e.g. sodium thiosulphate, sulphite, or bisulphite. (author)

  16. Regulation of capsule in Neisseria meningitidis.

    Science.gov (United States)

    Tzeng, Yih-Ling; Thomas, Jennifer; Stephens, David S

    2016-09-01

    Neisseria meningitidis, a devastating pathogen exclusive to humans, expresses capsular polysaccharides that are the major meningococcal virulence determinants and the basis for successful meningococcal vaccines. With rare exceptions, the expression of capsule (serogroups A, B, C, W, X, Y) is required for systemic invasive meningococcal disease. Changes in capsule expression or structure (e.g. hypo- or hyper-encapsulation, capsule "switching", acetylation) can influence immunologic diagnostic assays or lead to immune escape. The loss or down-regulation of capsule is also critical in meningococcal biology facilitating meningococcal attachment, microcolony formation and the carriage state at human mucosal surfaces. Encapsulated meningococci contain a cps locus with promoters located in an intergenic region between the biosynthesis and the conserved capsule transport operons. The cps intergenic region is transcriptionally regulated (and thus the amount of capsule expressed) by IS element insertion, by a two-component system, MisR/MisS and through sequence changes that result in post-transcriptional RNA thermoregulation. Reversible on-off phase variation of capsule expression is controlled by slipped strand mispairing of homo-polymeric tracts and by precise insertion and excision of IS elements (e.g. IS1301) in the biosynthesis operon. Capsule structure can be altered by phase-variable expression of capsular polymer modification enzymes or "switched" through transformation and homologous recombination of different polymerases. Understanding the complex regulation of meningococcal capsule has important implications for meningococcal biology, pathogenesis, diagnostics, current and future vaccine development and vaccine strategies. PMID:26089023

  17. Preparation of irradiation capsules VISA II

    International Nuclear Information System (INIS)

    The objective of this work is to produce 5 capsules and a number of containers for irradiation of different samples in the RA reactor. Containers are placed inside the capsules which are introduced into the cylindrical fuel elements. Capsules are cooled by water circulation, the temperature remaining less than 80 deg C. A number of thermocouples are planned to be placed in the capsules and containers. During this preparation which demanded numerous techniques application of special plugs was started. Details of operations which enabled overcoming the difficulties of montage are shown

  18. Herniation of the anterior lens capsule

    Directory of Open Access Journals (Sweden)

    Pereira Nolette

    2007-01-01

    Full Text Available Herniation of the anterior lens capsule is a rare abnormality in which the capsule bulges forward in the pupillary area. This herniation can be mistaken for an anterior lenticonus where both the capsule and the cortex bulge forward. The exact pathology behind this finding is still unclear. We report the clinical, ultrasound biomicroscopy (UBM and histopathological findings of a case of herniation of the anterior lens capsule. UBM helped to differentiate this entity from anterior lenticonus. Light microscopy revealed capsular splitting suggestive of capsular delamination and collection of fluid (aqueous in the area of herniation giving it a characteristic appearance.

  19. Exposure to slim images in mass media: Television commercials as reminders of restriction in restrained eaters [reprint

    NARCIS (Netherlands)

    Anschutz, D.J.; Strien, T. van; Engels, R.C.M.E.

    2011-01-01

    This reprinted article originally appeared in Health Psychology, 2008 (Jul), Vol 27(4), 401-408. (The following abstract of the original article appeared in record 2008-09239-001). Objective: The aim of the present study was to explore the effects of exposure to slim images and diet-related products

  20. Uneasy money: the Instituto Carlos Slim de la Salud, tobacco philanthropy and conflict of interest in global health.

    Science.gov (United States)

    Burch, Tiffany; Wander, Nathaniel; Collin, Jeff

    2010-12-01

    In May 2007, the Instituto Carso de la Salud-now Instituto Carlos Slim de la Salud (ICSS)-was endowed with US$500 million to focus on priority health issues in Latin America, notably issues of 'globalisation and non-communicable diseases'. ICSS was soon criticised, however, on the grounds that its funding was derived from tobacco industry profits and that its founder Carlos Slim Hélu remained an active industry principal. Collaboration with ICSS was said to run counter to the WHO Framework Convention on Tobacco Control. The Institute's then Executive President Julio Frenk disputed these charges. This research employs an archive of tobacco industry documents triangulated with materials from commercial, media, regulatory and NGO sources to examine the financial relations between Slim and the tobacco industry. The paper analyses Slim's continuing service to the industry and role in ICSS. It demonstrates a prima facie conflict of interest between ICSS's health mission and its founder's involvement in cigarette manufacturing and marketing, reflected on ICSS's website as a resounding silence on issues of tobacco and health. It is concluded that the reliance of international health agencies upon the commercial sector requires more robust institutional policies to effectively regulate conflicts of interest. PMID:21088061

  1. Shen Wu capsule affects the cognitive function and apoptosis protein in the ischemic-diabetic compound model rats

    Institute of Scientific and Technical Information of China (English)

    Chenlian-zhen; Lilin; Anwen-lin; Zhangli; Chujin

    2004-01-01

    Aim: To explore the mechanism of diabetes mellitus eneephalopathy and the effect of cognitive function of Chinese patent medicine Shen Wu capsule and intervention to apoptosis in the ischemic diabetic compound model rats. Methods:The compound model of Wistar rats was duplicated with streptozotocin (STZ) (60mg/kg) once intraperitoneally and transient

  2. Pressurised capsules for irradiation creep experiments

    International Nuclear Information System (INIS)

    Zircaloy-2 and Zr-2.5% Nb alloy are used as pressure tube materials of Pressurised Heavy Water Reactors (PHWRs) and D9 is the alloy selected for fuel cladding and wrapper tubes of Prototype Fast Breeder Reactor (PFBR). Due to intense neutron flux and high temperature that prevails in nuclear reactors, there will be degradation in the mechanical properties of these structural materials such as ductility, impact strength and in-reactor creep strength. It is essential to assess the in-reactor creep performance of indigenously, developed zirconium alloys and D9 alloy. Out of the various methods used for carrying out in-reactor creep experiments, miniature pressurised capsule method is an attractive option since pressurised capsules occupy very less space and many such capsules can be irradiated in the limited irradiation space available in a reactor. Pressurised capsules made of zirconium alloys and D9 alloy have been developed at IGCAR to determine the in-reactor creep performance of indigenously developed zirconium alloys and D9 alloy. The pressurised capsule is made of the same material for which the irradiation creep data is required. It is in the form of a gas filled tube with both ends sealed. A pressurising gas such as argon is filled in the pressurised capsule at high pressure. The filling pressure of pressurised capsule at room temperature is chosen in such a way that the target stresses are attained in the pressurised capsule at the desired temperature of irradiation in the reactor. Zirconium alloy pressurised capsules have been subjected to irradiation in Fast Breeder Test Reactor (FBTR) and pressurised capsules of D9 alloy have been fabricated and are being subjected to low temperature and low fluence irradiation in FBTR. This paper briefly discusses the irradiation creep experiments using pressurised capsules of zirconium alloy and D9 alloy and the results obtained from zirconium alloy creep experiments. (author)

  3. Formulation, process development and evaluation of artemether and lumefantrine soft gelatin capsule

    OpenAIRE

    Patel, A; Lodha, A.; Chaudhuri, J.; P Jadia; Joshi, T.; Dalal, J.

    2012-01-01

    Artemether and Lumefantrine capsules are indicated for the treatment of P. falciparum malaria cases resistant to both chloroquine and sulphadoxine, pyrimethamine combination. Both artemether and lumefantrine act as blood schizontocides. Artemether is a sesquiterpene lactone derived from artemisinin. Artemisinin is a compound derived from the sweet wormwood plant and has been used for centuries in traditional Chinese medicine to treat fever. Lumefantrine is a synthetic aryl-amino alcohol antim...

  4. Research on the Capsule of Ganoderma lucidum and Zizhiphi spinozae Improving the Sleep in Mice

    Directory of Open Access Journals (Sweden)

    Ya-Li Dang

    2014-03-01

    Full Text Available Nowadays, more and more people are suffering from insomnia with difficulty in initiating or maintaining sleep. Ganoderma lucidum (G. lucidum and Ziziphi spinosae (Z. Spinosae are conventional herbal drugs in traditional Chinese medicine and they have been used lonely for the treatment of insomnia. In the present study, G. lucidum and Z. spinosae were combined and the active fractions were extracted to make the capsule. Furthermore, their effect on improving sleep in mice was investigated. The functional compositions of the capsule were polysaccharide, total flavone, spinosin and triterpenoid, with the content being 12.08, 1.35, 0.67 and 1.50 g/100 g, respectively. The effect of the capsule on improving sleep in mice was studied. Results showed no effects on the sleep induced directly in mice assessed with the loss-of-righting reflex even at the high dose of 450, 1350 mg/kg/day. However, the capsule significantly decreased sleep latency and increased sleeping time and prolonged sleeping time induced by pentobarbital sodium at high doses. In conclusion, the capsule of G. lucidum and Z. spinozae combined had the function of improving sleep

  5. The pipeline flow of heavy solid capsules

    Czech Academy of Sciences Publication Activity Database

    Vlasák, Pavel

    Shanghai, 2004, s. 1-16. [International symposium on underground freight transportation by capsule pipelines and other tube/tunnel system s /4./. Shanghai (CN), 00.00.2004] R&D Projects: GA AV ČR KSK2067107 Institutional research plan: CEZ:AV0Z2060917 Keywords : pipeline transport * solid capsules * correlation Subject RIV: BK - Fluid Dynamics

  6. Thermal Analysis Study of Irradiation Capsule

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Ryul; Cho, Man Soon; Choo, Kee Nam; Kang, Young Hwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    To predict the temperature distribution in the capsule, the temperature analysis is performed using the Thermal analysis code. In this study, we investigated to which one gives better results in estimating temperatures of capsule using several thermal analysis codes. To evaluate the correct temperature, the analysis results are compared with the irradiation test data of 10M-01K capsule. Ideal analysis method for thermal analysis is investigated to using several thermal analysis codes. To evaluate the correct temperature, the analysis results are compared with the irradiation test data of 10M-01K capsule. The temperature distribution for the center of specimen in capsule is influenced the gap between the thermal media and external tube and the helium pressure. At position of helium gap, the temperature of the capsule in the radial direction is rapidly decreased. The temperatures by HEATING 7.2f and ANSYS 14.0 using finite element model are similar to each other. The temperature by ANSYS 14.0 code has the error rate of 5.35% and it is the best agreement with the irradiation test data of 10M-01K. The results of this study will be helpful to thermal analysis of capsule design. To The reliability of the temperature, should be more study for thermal mechanism about irradiation capsule.

  7. Design of LED backlight system used for ultra-slim LCD TV

    Science.gov (United States)

    Li, Xiuzhen; Ma, Guoheng; Yang, Dongsheng; Liu, Fei; Wan, Lifang; Qiao, Zhonglian

    2010-07-01

    Large-size LED backlight is the new development trend of flat-panel TV industry. A large-sized ultra-slim edge-light type LED backlight is designed in this paper. Depending of the research of the LED manufacturers, LED is chose by the consideration of luminous efficiency, power consumption, structure design, etc. The LGP is designed through the optical design software; According to the specification and number of LED, the light-bar is designed to be double-layer MCPCB, and high voltage design is adopted in the driver control circuit which supports the PWM dimming; In order to achieve a better cooling effect, thermal design is carried out. The edge light type LED backlight designed in this paper, and backlight 9.9 mm thickness, 150W power, 5700nit center brightness, the uniformity is 82% by testing. It reaches a leading level of industry.

  8. Cross-correlation measurement techniques for cavity-based axion and weakly interacting slim particle searches

    CERN Document Server

    Parker, Stephen R; Ivanov, Eugene N; Tobar, Michael E

    2015-01-01

    Weakly Interacting Slim Particles (WISPs), such as axions, are highly motivated dark matter candidates. The most sensitive experimental searches for these particles exploit WISP-to-photon conversion mechanisms and use resonant cavity structures to enhance the resulting power signal. For WISPs to constitute Cold Dark Matter their required masses correspond to photons in the microwave spectrum. As such, searches for these types of WISPs are primarily limited by the thermal cavity noise and the broadband first-stage amplifier noise. In this work we propose and then verify two cross-correlation measurement techniques for cavity-based WISP searches. These are two channel measurement schemes where the cross-spectrum is computed, rejecting uncorrelated noise sources while still retaining correlated signals such as those generated by WISPs. The first technique allows for the cavity thermal spectrum to be observed with an enhanced resolution. The second technique cross-correlates two individual cavity/amplifier system...

  9. Evolutionary enhancement of the SLIM-MAUD method of estimating human error rates

    International Nuclear Information System (INIS)

    The methodology described in this paper assigns plant-specific dynamic human error rates (HERs) for individual plant examinations based on procedural difficulty, on configuration features, and on the time available to perform the action. This methodology is an evolutionary improvement of the success likelihood index methodology (SLIM-MAUD) for use in systemic scenarios. It is based on the assumption that the HER in a particular situation depends of the combined effects of a comprehensive set of performance-shaping factors (PSFs) that influence the operator's ability to perform the action successfully. The PSFs relate the details of the systemic scenario in which the action must be performed according to the operator's psychological and cognitive condition

  10. Adhesive capsulitis of the shoulder: MR arthrography

    International Nuclear Information System (INIS)

    Adhesive capsulitis is a clinical syndrome involving pain and decreased joint motion caused by thickening and contraction of the joint capsule. The purpose of this study is to describe the MR arthrographic findings of this syndrome. Twenty-nine sets of MR arthrographic images were included in the study. Fourteen patients had adhesive capsulitis diagnosed by physical examination and arthrography, and their MR arthrographic findings were compared with those of 15 subjects in the control group. The images were retrospectively reviewed with specific attention to the thickness of the joint capsule, volume of the axillary pouch (length, width, height(depth)), thinkness of the coracohumeral ligament, presence of extra-articular contrast extravasation, and contrst filling of the subcoracoid bursa. Mean capsular thickness measured at the inferior portion of the axillary pouch was 4.1 mm in patients with adhesive capsulitis and 1.5 mm in the control group. The mean width of the axillary pouch was 2.5 mm in patients and 9.5 mm in controls. In patients, the capsule was significantly thicker and the axillary pouch significantly narrower than in controls (p<0.05). Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch (sensitivity 93%, specificity 80%) and a pouch narrower than 3.5 mm (sensitivity 93%, specificity 100%) were useful criteria for the diagnosis of adhesive capsulitis. In patients with this condition, extra-articular contrast extravasation was noted in six patients (43%) and contrast filling of the subcoracoid bursa in three (21%). The MR arthrographic findings of adhesive capsulitis are capsular thickening, a low-volume axillary pouch, extra-articular contrast extravasation, and contrast filling of the subcoracoid bursa. Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch and a pouch width of less than 3.5 mm are useful diagnostic imaging characteristics

  11. Hydrodynamick instabilities on ICF capsules

    International Nuclear Information System (INIS)

    This article summarizes our current understanding of hydrodynamic instabilities as relevant to ICF. First we discuss classical, single mode Rayleigh-Taylor instability, and nonlinear effects in the evolution of a single mode. Then we discuss multimode systems, considering: (1) the onset of nonlinearity; (2) a second order mode coupling theory for weakly nonlinear effects, and (3) the fully nonlinear regime. Two stabilization mechanisms relevant to ICF are described next: gradient scale length and convective stabilization. Then we describe a model which is meant to estimate the weakly nonlinear evolution of multi-mode systems as relevant to ICF, given the short-wavelength stabilization. Finally, we discuss the relevant code simulation capability, and experiments. At this time we are quite optimistic about our ability to estimate instability growth on ICF capsules, but further experiments and simulations are needed to verify the modeling. 52 refs

  12. Effectiveness of Qiangjijianli capsule on experimental autoimmune myasthenia gravis

    Institute of Scientific and Technical Information of China (English)

    Shunmin Li; Bo Fu; Yuyan Li; DongYang; Shudong Yang

    2006-01-01

    BACKGROUND: Experimental autoimmune myasthenia gravis(EAMG) and anti-AchR antibody of human myasthenia gravis are the same immune globulin.This antibody restricts the activity of nicotinic acetylcholine receptor and the amount of receptor binding sites is decreased,so myasthenia gravis occurs.OBJECTIVE: To observe the therapeutic effect and mechanism of action of Qiangjijianli capsule on EAMG rats.DESIGN:A randomized controlled animal experiment.SETTING: Experimental Animal Center of Guangzhou University of Traditional Chinese Medicine.MATERIALS: Acetylcholine receptors(AchR)were extracted from electric skate's electric organ which lives in the sea near Guangzhou.It had high biological activity and the protein content was 1.63 g/L.Qiangjijianli capsule (Astragalus mongholicus,Codonopsis pilosula,Atractylodes macrocephala,Angelica sinensis,Bupleurum chinense,Cairo morningglory root or leaf,Glycyrrhixa uralensis,etc.0.5 g crude drug per capsule) was bought from the Manufacturing Laboratory of Guangzhou University of Traditional Chinese Medicine with the Batch No.89-11-1.METHODS:This experiment was carried out in the Experimental Animal Center of Guangzhou University of Traditional Chinese Medicine from May to August 1990.①Adult female SD rats were immunized with AchR.The animals' movement condition was observed and recorded everyday. Ten rats were chosen as normal control group.and they were not given any treatment and raised normally.After modeled,20 successful rats were randomly assigned into 2 groups:treatmental group and model group. 2 mL Qiangjijianli capsule suspension(1 g)was intragastrically administrated into each rat of treatmental group for 30 days; The same amount of clean water was intragastrically administrated into the rats of model group for 30 days.(2)Serum AchR antibody was measured with ABC-ELISA method. After administration,the rats were sacrificed.The complete diaphragmatic muscle was extracted for in vitro receptor binding test

  13. [Evaluation of nopal capsules in diabetes mellitus].

    Science.gov (United States)

    Frati Munari, A C; Vera Lastra, O; Ariza Andraca, C R

    1992-01-01

    To find out if commercial capsules with dried nopal (prickle-pear cactus, Opuntia ficus indica may have a role in the management of diabetes mellitus, three experiments were performed: 30 capsules where given in fasting condition to 10 diabetic subjects and serum glucose was measured through out 3 hours; a control test was performed with 30 placebo capsules. OGTT with previous intake of 30 nopal or placebo capsules was performed in ten healthy individuals. In a crossover and single blinded study 14 diabetic patients withdrew the oral hypoglycemic treatment and received 10 nopal or placebo capsules t.i.d. during one week; serum glucose, cholesterol and tryglycerides levels were measured before and after each one-week period. Five healthy subjects were also studied in the same fashion. Opuntia capsules did not show acute hypoglycemic effect and did not influence OGTT. In diabetic patients serum glucose, cholesterol and tryglycerides levels did not change with Opuntia, but they increased with placebo (P nopal, while cholesterol and triglycerides decreased (P < 0.01 vs. placebo). The intake of 30 Opuntia capsules daily in patients with diabetes mellitus had a discrete beneficial effect on glucose and cholesterol. However this dose is unpractical and at present it is not recommended in the management of diabetes mellitus. PMID:1307994

  14. Advances in material capsule technology in HANARO

    International Nuclear Information System (INIS)

    A material capsule system has been developed for irradiation tests of non-fissile materials in HANARO. This capsule system has been actively utilized for various material irradiation tests requested by users from research institutes, universities, and the industries. Based on the accumulated experience and the user's sophisticated requirements, several advances in material capsule technologies were obtained recently for a more precise control and analysis of the neutron irradiation effect in HANARO. New instrumented capsule technologies for a more precise control of the irradiation temperature and fluence of a specimen, irrespective of the reactor operation, have been developed and out-pile tested. The OR/IP capsule technologies for an irradiation test in the HANARO OR and IP test holes with a relatively lower neutron flux than the CT and IR test holes have also been developed and in-pile tested, successfully. A high temperature irradiation technology up to 1000degC is under development. An evaluation of the DPA (Displacement Per Atom) and activation of irradiated specimens was attempted by using the SPECTOR and ORIGEN2 codes, respectively. A new fluence monitor with a decreased activity was designed to measure the thermal and fast neutron fluences of the irradiated specimens. A friction welded tube using STS304 and Al1050 alloys was introduced to prevent a coolant leakage into a capsule during a capsule cutting process after an irradiation. (author)

  15. Advances in material capsule technology in HANARO

    International Nuclear Information System (INIS)

    A material capsule system has been developed for irradiation tests of non fissile materials in HANARO. This capsule system has been actively utilized for various material irradiation tests requested by users from research institutes, universities, and the industries. Based on the accumulated experience and the user's sophisticated requirements, several advances in material capsule technologies were obtained recently for a more precise control and analysis of the neutron irradiation effect in HANARO. New instrumented capsule technologies for a more precise control of the irradiation temperature and fluence of a specimen, irrespective of the reactor operation, have been developed and out pile tested. The OR/IP capsule technologies for an irradiation test in the HANARO OR and IP test holes with a relatively lower neutron flux than the CT and IR test holes have also been developed and in pile tested, successfully. A high temperature irradiation technology up to 1000 .deg. C is under development. An evaluation of the DPA (Displacement Per Atom) and activation of irradiated specimens was attempted by using the SPECTOR and ORIGEN2 codes, respectively. A new fluence monitor with a decreased activity was designed to measure the thermal and fast neutron fluences of the irradiated specimens. A friction welded tube using STS304 and Al1050 alloys was introduced to prevent a coolant leakage into a capsule during a capsule cutting process after an irradiation

  16. Asymmetric membrane osmotic capsules for terbutaline sulphate

    Directory of Open Access Journals (Sweden)

    N G Gobade

    2012-01-01

    Full Text Available The aim of the present study was to design an asymmetric membrane capsule, an osmotic pump-based drug delivery system of ethyl cellulose for controlled release of terbutaline sulphate. asymmetric membrane capsules contains pore-forming water soluble additive, sorbitol in different concentrations in the capsule shell membrane, which after coming in contact with water, dissolves, resulting in an in situ formation of a microporous structure. The terbutaline sulphate is a β-adrenoreceptor agonist widely used in the treatment of asthma. The oral dosage regimen of terbutaline sulphate is 5 mg twice or thrice daily, the plasma half-life is approximate 3-4 h and it produces GI irritation with extensive first pass metabolism. Hence, terbutaline sulphate was chosen as a model drug with an aim to develop controlled release system. Different formulations of ethyl cellulose were prepared by phase inversion technique using different concentrations of sorbitol as pore forming agent. It was found that the thickness of the prepared asymmetric membrane capsules was increased with increase in concentration of ethyl cellulose and pore forming agent, i.e. sorbitol. The dye release study in water and 10% sodium chloride solution indicates that, the asymmetric membrane capsules follow osmotic principle to release content. The pores formed due to sorbitol were confirmed by microscopic observation of transverse section of capsule membrane. Data of in vitro release study of terbutaline sulphate from asymmetric membrane capsules indicated that, the capsules prepared with 10% and 12.5% of ethyl cellulose and 25% of sorbitol released as much as 97.44% and 76.27% in 12 h, respectively with zero order release rate. Hence asymmetric membrane capsule of 10% ethyl cellulose and 25% of sorbitol is considered as optimum for controlled oral delivery of terbutaline sulphate.

  17. Asymmetric membrane osmotic capsules for terbutaline sulphate.

    Science.gov (United States)

    Gobade, N G; Koland, Marina; Harish, K H

    2012-01-01

    The aim of the present study was to design an asymmetric membrane capsule, an osmotic pump-based drug delivery system of ethyl cellulose for controlled release of terbutaline sulphate. asymmetric membrane capsules contains pore-forming water soluble additive, sorbitol in different concentrations in the capsule shell membrane, which after coming in contact with water, dissolves, resulting in an in situ formation of a microporous structure. The terbutaline sulphate is a β-adrenoreceptor agonist widely used in the treatment of asthma. The oral dosage regimen of terbutaline sulphate is 5 mg twice or thrice daily, the plasma half-life is approximate 3-4 h and it produces GI irritation with extensive first pass metabolism. Hence, terbutaline sulphate was chosen as a model drug with an aim to develop controlled release system. Different formulations of ethyl cellulose were prepared by phase inversion technique using different concentrations of sorbitol as pore forming agent. It was found that the thickness of the prepared asymmetric membrane capsules was increased with increase in concentration of ethyl cellulose and pore forming agent, i.e. sorbitol. The dye release study in water and 10% sodium chloride solution indicates that, the asymmetric membrane capsules follow osmotic principle to release content. The pores formed due to sorbitol were confirmed by microscopic observation of transverse section of capsule membrane. Data of in vitro release study of terbutaline sulphate from asymmetric membrane capsules indicated that, the capsules prepared with 10% and 12.5% of ethyl cellulose and 25% of sorbitol released as much as 97.44% and 76.27% in 12 h, respectively with zero order release rate. Hence asymmetric membrane capsule of 10% ethyl cellulose and 25% of sorbitol is considered as optimum for controlled oral delivery of terbutaline sulphate. PMID:23204625

  18. Self-shadowing Effects of Slim Accretion Disks in Active Galactic Nuclei: Diverse Appearance of the Broad-line Region

    CERN Document Server

    Wang, J -M; Du, P; Ho, L C

    2014-01-01

    Supermassive black holes in active galactic nuclei (AGNs) undergo a wide range of accretion rates, which lead to diversity of appearance. We consider the effects of anisotropic radiation from accretion disks on the broad-line region (BLR), from the Shakura-Sunyaev regime to slim disks with super-Eddington accretion rates. The geometrically thick funnel of the inner region of slim disks produces strong self-shadowing effects that lead to very strong anisotropy of the radiation field. We demonstrate that the degree of anisotropy of the radiation fields grows with increasing accretion rate. As a result of this anisotropy, BLR clouds receive different spectral energy distributions depending on their location relative to the disk, resulting in diverse observational appearance of the BLR. We show that the self-shadowing of the inner parts of the disk naturally produces two dynamically distinct regions of the BLR, depending on accretion rate. These two regions manifest themselves as kinematically distinct components...

  19. Capsule Retentions and Incomplete Capsule Endoscopy Examinations: An Analysis of 2300 Examinations

    OpenAIRE

    Charlotte M. Höög; Lars-Åke Bark; Juan Arkani; Jacob Gorsetman; Olle Broström; Urban Sjöqvist

    2011-01-01

    Aim. To evaluate capsule endoscopy in terms of incomplete examinations and capsule retentions and to find risk factors for these events. Material and Methods. This retrospective and consecutive study includes data from 2300 capsule enteroscopy examinations, performed at four different hospitals in Stockholm, Sweden from 2003 to 2009. Results. The frequency of incomplete examinations was 20%. Older age, male gender, suspected, and known Crohn's disease were risk factors for an incomplete exami...

  20. 21 CFR 520.1660b - Oxytetracycline hydrochloride capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride capsules. 520.1660b... Oxytetracycline hydrochloride capsules. (a) Specifications. The drug is in capsule form with each capsule containing 125 or 250 milligrams of oxytetracycline hydrochloride. Oxytetracycline is the...

  1. Slim-Filter: an interactive windows-based application for illumina genome analyzer data assessment and manipulation

    Directory of Open Access Journals (Sweden)

    Golovko Georgiy

    2012-07-01

    Full Text Available Abstract Background The emergence of Next Generation Sequencing technologies has made it possible for individual investigators to generate gigabases of sequencing data per week. Effective analysis and manipulation of these data is limited due to large file sizes, so even simple tasks such as data filtration and quality assessment have to be performed in several steps. This requires (potentially problematic interaction between the investigator and a bioinformatics/computational service provider. Furthermore, such services are often performed using specialized computational facilities. Results We present a Windows-based application, Slim-Filter designed to interactively examine the statistical properties of sequencing reads produced by Illumina Genome Analyzer and to perform a broad spectrum of data manipulation tasks including: filtration of low quality and low complexity reads; filtration of reads containing undesired subsequences (such as parts of adapters and PCR primers used during the sample and sequencing libraries preparation steps; excluding duplicated reads (while keeping each read’s copy number information in a specialized data format; and sorting reads by copy numbers allowing for easy access and manual editing of the resulting files. Slim-Filter is organized as a sequence of windows summarizing the statistical properties of the reads. Each data manipulation step has roll-back abilities, allowing for return to previous steps of the data analysis process. Slim-Filter is written in C++ and is compatible with fasta, fastq, and specialized AS file formats presented in this manuscript. Setup files and a user’s manual are available for download at the supplementary web site (https://www.bioinfo.uh.edu/Slim_Filter/. Conclusion The presented Windows-based application has been developed with the goal of providing individual investigators with integrated sequencing reads analysis, curation, and manipulation capabilities.

  2. Adapting the SLIM diabetes prevention intervention to a Dutch real-life setting: joint decision making by science and practice

    OpenAIRE

    2013-01-01

    Background Although many evidence-based diabetes prevention interventions exist, they are not easily applicable in real-life settings. Moreover, there is a lack of examples which describe the adaptation process of these interventions to practice. In this paper we present an example of such an adaptation. We adapted the SLIM (Study on Lifestyle intervention and Impaired glucose tolerance Maastricht) diabetes prevention intervention to a Dutch real-life setting, in a joint decision making proce...

  3. Adapting the SLIM diabetes prevention intervention to a Dutch real-life setting: joint decision making by science and practice

    OpenAIRE

    Jansen, S.C.; Haveman-Nies, A.; Duijzer, G.; Beek, ter, J.; Hiddink, G.; Feskens, E.J.M.

    2013-01-01

    Background - Although many evidence-based diabetes prevention interventions exist, they are not easily applicable in real-life settings. Moreover, there is a lack of examples which describe the adaptation process of these interventions to practice. In this paper we present an example of such an adaptation. We adapted the SLIM (Study on Lifestyle intervention and Impaired glucose tolerance Maastricht) diabetes prevention intervention to a Dutch real-life setting, in a joint decision making pro...

  4. Development of plastic capsule for research reactor irradiation

    International Nuclear Information System (INIS)

    New irradiation capsule for the research reactor was developed using a radiation resistant polymer, Polyethylene-2, 6-Naphthalate (PEN). This capsule has several merits such as low activity after irradiation, low price by mass production using injection moulding, and good irradiation performance for application to 12 hours irradiation in Japan Research Reactor No. 4 (JRR-4). Using this capsule, more efficient irradiation can be done because the sample can be taken off from the capsule immediately after irradiation, and this PEN capsule can be replaced with ordinary aluminum capsule for JRR-4 irradiation. This report describes the development of PEN capsule and the irradiation tests. (author)

  5. Blanket concept of water-cooled lithium lead with beryllium for the SlimCS fusion DEMO reactor

    International Nuclear Information System (INIS)

    As an advanced option for SlimCS blanket, conceptual design study of water-cooled lithium lead (WCLL) blanket was performed. In SlimCS, the net tritium breeding ratio (TBR) supplied from WCLL blanket was not enough because the thickness of blanket in SlimCS was limited to about 0.5 m so as to allocate the conducting shell position near the plasma for high beta access and vertical stability of plasma. Therefore, the beryllium (Be) pebble bed was adopted as additional multiplier to reach a required TBR (≥ 1.05). Considering the operating temperature of blanket materials, a double pipe structure was adopted. The nuclear and thermal analysis were carried out by a nuclear-thermal-coupled code, ANIHEAT and DOHEAT so that blanket materials were appropriately arranged to satisfy the acceptable operation temperatures. The temperatures of materials were kept in appropriate range for the neutron wall load Pn = 5 MW/m2. It was found that the local TBR of WCLL with Be blanket was comparable with that of solid breeder blanket. (author)

  6. Design, fabrication and inspection of rabbit capsule

    International Nuclear Information System (INIS)

    Many capsules designed by Irradiation Div. 1 have been irradiated in the JMTR reactor in past years. The Irradiation Div. 1 has been developing and studying the irradiation and design techniques. This report contains the description of the design and inspection standard, fabrication and the basic design of small capsule called ''Rabbit''. Therefore, this report is very useful for proposer who want to irradiate small specimen by irradiation facility in the JMTR reactor. (author)

  7. Capsule endoscopy in patients refusing conventional endoscopy

    OpenAIRE

    Romero-Vázquez, Javier; Argüelles-Arias, Federico; García-Montes, Josefa Maria; Caunedo-Álvarez, Ángel; Pellicer-Bautista, Francisco Javier; Herrerías-Gutiérrez, Juan Manuel

    2014-01-01

    Capsule endoscopy is nowadays the diagnostic technique of choice in the study of small bowel pathologies, allowing the non-invasive study of the entire mucosa. This has led, together with new technical advances, to the creation of two new models (PillCam ESO and PillCam Colon) for the study of esophageal and colonic diseases. These two new capsules offer an interesting alternative to conventional endoscopy in the study of the upper and lower digestive tracts, because traditional endoscopy is ...

  8. Towards Polymer-Based Capsules with Drastically Reduced Controlled Permeability

    Science.gov (United States)

    Andreeva, Daria V.; Sukhorukov, Gleb B.

    Small molecules (dyes, therapeutics, etc.) could be easily handled, stored, delivered, and released by polyelectrolyte capsules. To make the polyelectrolyte capsule more efficient for small molecule encapsulation, capsule permeability should be significantly decreased. Here, we demonstrate the possibility to entrap water-soluble molecular species into polyelectrolyte capsules modified by a low permeable dense polymer (polypyrrole). Possible future areas in PE capsule application as carriers for gases and volatiles in the pharmaceutical, food, and gases industry, agriculture and cosmetology are discussed.

  9. The Scaling LInear Macroweather model (SLIM): using scaling to forecast global scale macroweather from months to decades

    Science.gov (United States)

    Lovejoy, S.; del Rio Amador, L.; Hébert, R.

    2015-03-01

    At scales of ≈ 10 days (the lifetime of planetary scale structures), there is a drastic transition from high frequency weather to low frequency macroweather. This scale is close to the predictability limits of deterministic atmospheric models; so that in GCM macroweather forecasts, the weather is a high frequency noise. But neither the GCM noise nor the GCM climate is fully realistic. In this paper we show how simple stochastic models can be developped that use empirical data to force the statistics and climate to be realistic so that even a two parameter model can outperform GCM's for annual global temperature forecasts. The key is to exploit the scaling of the dynamics and the enormous stochastic memories that it implies. Since macroweather intermittency is low, we propose using the simplest model based on fractional Gaussian noise (fGn): the Scaling LInear Macroweather model (SLIM). SLIM is based on a stochastic ordinary differential equations, differing from usual linear stochastic models (such as the Linear Inverse Modelling, LIM) in that it is of fractional rather than integer order. Whereas LIM implicitly assumes there is no low frequency memory, SLIM has a huge memory that can be exploited. Although the basic mathematical forecast problem for fGn has been solved, we approach the problem in an original manner notably using the method of innovations to obtain simpler results on forecast skill and on the size of the effective system memory. A key to successful forecasts of natural macroweather variability is to first remove the low frequency anthropogenic component. A previous attempt to use fGn for forecasts had poor results because this was not done. We validate our theory using hindcasts of global and Northern Hemisphere temperatures at monthly and annual resolutions. Several nondimensional measures of forecast skill - with no adjustable parameters - show excellent agreement with hindcasts and these show some skill even at decadal scales. We also compare

  10. Crump Geyser Exploration and Drilling Project. High Precision Geophysics and Detailed Structural Exploration and Slim Well Drilling

    Energy Technology Data Exchange (ETDEWEB)

    Fairbank, Brian D. [Nevada Geothermal Power Company, Vancouver (Canada); Smith, Nicole [Nevada Geothermal Power Company, Vancouver (Canada)

    2015-06-10

    The Crump Geyser Exploration and Drilling Project – High Precision Geophysics and Detailed Structural Exploration and Slim Well Drilling ran from January 29, 2010 to September 30, 2013. During Phase 1 of the project, collection of all geophysical surveys was completed as outlined in the Statement of Project Objectives. In addition, a 5000-foot full sized exploration well was drilled by Ormat, and preexisting drilling data was discovered for multiple temperature gradient wells within the project area. Three dimensional modeling and interpretation of results from the geophysical surveys and drilling data gave confidence to move to the project into Phase 2 drilling. Geological and geophysical survey interpretations combined with existing downhole temperature data provided an ideal target for the first slim-hole drilled as the first task in Phase 2. Slim-hole 35-34 was drilled in September 2011 and tested temperature, lithology, and permeability along the primary range-bounding fault zone near its intersection with buried northwest-trending faults that have been identified using geophysical methods. Following analysis of the results of the first slim-hole 35-34, the second slim hole was not drilled and subsequent project tasks, including flowing differential self-potential (FDSP) surveys that were designed to detail the affect of production and injection on water flow in the shallow aquifer, were not completed. NGP sold the Crump project to Ormat in August 2014, afterwards, there was insufficient time and interest from Ormat available to complete the project objectives. NGP was unable to continue managing the award for a project they did not own due to liability issues and Novation of the award was not a viable option due to federal award timelines. NGP submitted a request to mutually terminate the award on February 18, 2015. The results of all of the technical surveys and drilling are included in this report. Fault interpretations from surface geology, aeromag

  11. Capsule endoscopy in neoplastic diseases

    Institute of Scientific and Technical Information of China (English)

    Marco Pennazio; Emanuele Rondonotti; Roberto de Franchis

    2008-01-01

    Until recently,diagnosis and management of small-bowel tumors were delayed by the difficulty of access to the small bowel and the poor diagnostic capabilities of the available diagnostic techniques.An array of new methods has recently been developed,increasing the possibility of detecting these tumors at an earlier stage.Capsule endoscopy (CE) appears to be an ideal tool to recognize the presence of neoplastic lesions along this organ,since it is non-invasive and enables the entire small bowel to be visualized.Highquality images of the small-bowel mucosa may be captured and small and fiat lesions recognized,without exposure to radiation.Recent studies on a large population of patients undergoing CE have reported small-bowel tumor frequency only slightly above that reported in previous surgical series (range,1.6%-2.4%)and have also confirmed that the main clinical indication to CE in patients with small-bowel tumors is obscure gastrointestinal (GI) bleeding.The majority of tumors identified by CE are malignant;many were unsuspected and not found by other methods.However,it remains difficult to identify pathology and tumor type based on the lesion's endoscopic appearance.Despite its limitations,CE provides crucial information leading in most cases to changes in subsequent patient management.Whether the use of CE in combination with other new diagnostic (MRI or multidetector CT enterography) and therapeutic (Push-and-pull enteroscopy) techniques will lead to earlier diagnosis and treatment of these neoplasms,ultimately resulting in a survival advantage and in cost savings,remains to be determined through carefully-designed studies.

  12. Optimized slim-line logging NMR tool to measure soil moisture in situ.

    Science.gov (United States)

    Perlo, Josefina; Danieli, Ernesto; Perlo, Juan; Blümich, Bernhard; Casanova, Federico

    2013-08-01

    We report the optimization of a slim-line logging NMR tool carried out by maximizing the signal-to-noise ratio of the NMR measurements. The tool, based on cylindrical permanent magnets of 20 cm length and 5 cm diameter, has a penetration depth of about 2 cm measured from its surface. This is obtained thanks to a large radio frequency coil whose dimensions are comparable to the sensor size. An analytical expression of the SNR as a function of parameters which take into account the interaction between the radio frequency coil and the magnet shielding is developed. In view of the external constrains such as the one imposed by the excavation hole, a proper tool size is determined in the optimization process. Due to its size and properties, the sensor is suitable to measure water content in the vadose zone, which is the zone comprised within the first meters of the Earth surface and whose study is important for improving water management in agriculture and for refining climate models. PMID:23757362

  13. Simplification of blanket system for SlimCS fusion DEMO reactor

    International Nuclear Information System (INIS)

    Simplification of blanket system is necessary for a fusion DEMO reactor. Although the conceptual design of a tritium-breeding blanket for SlimCS has been studied in the past several years, the structure of the previous blanket seems to be complex and difficult to manufacture from the viewpoint of engineering. In this paper, we proposed simplification of blanket structure without decreasing the net Tritium Breeding Ratio (TBR). In the proposed concept, the blanket is filled with the mixture of Li4SiO4 pebbles or Li2O pebbles for the tritium breeding and Be12Ti pebbles for the neutron multiplication. To confirm the effectiveness of this concept, an ANIHEAT code with the nuclear library FENDL-2.0 was used for calculations of the neutronic and thermal analyses. The result indicated that, under the constraint of the blanket thickness being less than 0.5 m, the mixture of Li2O pebbles and Be12Ti ones is the most effective and that the TBR is expected to be greater than 1.05.

  14. Slim-structured electro-floating display system based on the polarization-controlled optical path.

    Science.gov (United States)

    Kim, Seung-Cheol; Park, Seong-Jin; Kim, Eun-Soo

    2016-04-18

    A new slim-type electro-floating display system based on the polarization-controlled optical path is proposed. In the proposed system, the optical path between the input plane and Fresnel lens can be made recursive by repetitive transmission and reflection of the input beam by employing a new polarization-based optical path controller (P-OPC), which is composed of two quaterwave plates, a half mirror and a reflective polarizer. Based on this P-OPC, the absolute optical path between the input plane and Fresnel lens, virtually representing the physical depth of the display system, can be reduced down to one third of its original path, which results in the same rate of decrease in the volume size of the display system. The operational principle of the proposed system is analyzed with the Jones matrix. In addition, to confirm the feasibility of the proposed system, experiments with test prototypes are carried out, and the results are comparatively discussed with those of the conventional system. PMID:27137306

  15. Optimized slim-line logging NMR tool to measure soil moisture in situ

    Science.gov (United States)

    Perlo, Josefina; Danieli, Ernesto; Perlo, Juan; Blümich, Bernhard; Casanova, Federico

    2013-08-01

    We report the optimization of a slim-line logging NMR tool carried out by maximizing the signal-to-noise ratio of the NMR measurements. The tool, based on cylindrical permanent magnets of 20 cm length and 5 cm diameter, has a penetration depth of about 2 cm measured from its surface. This is obtained thanks to a large radio frequency coil whose dimensions are comparable to the sensor size. An analytical expression of the SNR as a function of parameters which take into account the interaction between the radio frequency coil and the magnet shielding is developed. In view of the external constrains such as the one imposed by the excavation hole, a proper tool size is determined in the optimization process. Due to its size and properties, the sensor is suitable to measure water content in the vadose zone, which is the zone comprised within the first meters of the Earth surface and whose study is important for improving water management in agriculture and for refining climate models.

  16. Commercial herbal slimming products: concern for the presence of heavy metals and bacteria.

    Science.gov (United States)

    Zin, Noraziah Mohamad; Chit, Yong Mei; Abu Bakar, Nur Faizah

    2014-02-01

    The increment of rate in obesity, the phenomenon of fat phobia as well as the increased use of herbal medicine had lead to the emergence of herbal slimming products. However, numerous bacteria and heavy metal contaminations are often found in herbal products due to irregular handling practices. Ten different brands of products (labeled as A-J) were investigated. Seven heavy metals content such as As, Cd, Pb, Co, Cr, Cu and Zn were analyzed using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) and bacterial presence was determined by counting the total aerobic count. The identification of isolates was carried out by macroscopic and microscopic observation, biochemical tests and confirmation using commercial kits of Microgen GN-ID A+B and API 20 E. The heavy metal contents in the samples were below the limit of the standard limitation by WHO and Health Canada. However, sample A contained the highest total daily intake of heavy metals. Total aerobic count was highest in sample H followed by G, A, B, C, F, D, E, I and J in which G and H exceeded the standard total aerobic count (10(5) CFU g(-1)) as given by WHO. A total of nine isolates of Bacillus spp. and ten gram-negative bacteria were isolated in which Bacillus cereus and Pseudomonas aeruginosa were found in samples C and F, respectively. Considering the fact that the herbal sliming products contained low concentration of heavy metals and bacteria count, it should be consumed with caution. PMID:24897789

  17. Inner Disc Obscuration in GRS 1915+105 Based on Relativistic Slim Disc Model

    CERN Document Server

    Vierdayanti, K; Mineshige, S; Bursa, M

    2013-01-01

    We study the observational signatures of the relativistic slim disc of 10 M_sun black hole, in a wide range of mass accretion rate, mdot, dimensionless spin parameter, a_ast, and viewing angle, i. In general, the innermost temperature, T_in increases with the increase of i for a fixed value of mdot and a_ast, due to the Doppler effect. However, for i > 50 and mdot > mdot_turn, T_in starts to decrease with the increase of mdot. This is a result of self-obscuration -- the radiation from the innermost hot part of the disc is blocked by the surrounding cooler part. The value of mdot_turn and the corresponding luminosities depend on a_ast and i. Such obscuration effects cause an interesting behavior on the disc luminosity (L_disc) -- T_in plane for high inclinations. In addition to the standard-disc branch which appears below mdot_turn and which obeys L_disc propto T_in^4 -relation, another branch above mdot_turn, which is nearly horizontal, may be observed at luminosities close to the Eddington luminosity. We sho...

  18. Non-linear evolution of thermally unstable slim accretion discs with a diffusive form of viscosity

    CERN Document Server

    Szuszkiewicz, E; Szuszkiewicz, Ewa; Miller, John C.

    2001-01-01

    We are carrying out a programme of non-linear time-dependent numerical calculations to study the evolution of the thermal instability driven by radiation pressure in transonic accretion discs around black holes. In our previous studies we first investigated the original version of the slim-disc model with low viscosity (parameter alpha = 0.001) for a stellar-mass (10 solar masses) black hole, comparing the behaviour seen with results from local stability analysis (which were broadly confirmed). In some of the unstable models, we saw a violently evolving shock-like feature appearing near to the sonic point. Next, we retained the original model simplifications but considered a higher value of alpha = 0.1 and demonstrated the existence of limit-cycle behaviour under suitable circumstances. The present paper describes more elaborate calculations with a more physical viscosity prescription and including a vertically integrated treatment of acceleration in the vertical direction. Limit-cycle behaviour is still foun...

  19. 3D Printed Programmable Release Capsules.

    Science.gov (United States)

    Gupta, Maneesh K; Meng, Fanben; Johnson, Blake N; Kong, Yong Lin; Tian, Limei; Yeh, Yao-Wen; Masters, Nina; Singamaneni, Srikanth; McAlpine, Michael C

    2015-08-12

    The development of methods for achieving precise spatiotemporal control over chemical and biomolecular gradients could enable significant advances in areas such as synthetic tissue engineering, biotic-abiotic interfaces, and bionanotechnology. Living organisms guide tissue development through highly orchestrated gradients of biomolecules that direct cell growth, migration, and differentiation. While numerous methods have been developed to manipulate and implement biomolecular gradients, integrating gradients into multiplexed, three-dimensional (3D) matrices remains a critical challenge. Here we present a method to 3D print stimuli-responsive core/shell capsules for programmable release of multiplexed gradients within hydrogel matrices. These capsules are composed of an aqueous core, which can be formulated to maintain the activity of payload biomolecules, and a poly(lactic-co-glycolic) acid (PLGA, an FDA approved polymer) shell. Importantly, the shell can be loaded with plasmonic gold nanorods (AuNRs), which permits selective rupturing of the capsule when irradiated with a laser wavelength specifically determined by the lengths of the nanorods. This precise control over space, time, and selectivity allows for the ability to pattern 2D and 3D multiplexed arrays of enzyme-loaded capsules along with tunable laser-triggered rupture and release of active enzymes into a hydrogel ambient. The advantages of this 3D printing-based method include (1) highly monodisperse capsules, (2) efficient encapsulation of biomolecular payloads, (3) precise spatial patterning of capsule arrays, (4) "on the fly" programmable reconfiguration of gradients, and (5) versatility for incorporation in hierarchical architectures. Indeed, 3D printing of programmable release capsules may represent a powerful new tool to enable spatiotemporal control over biomolecular gradients. PMID:26042472

  20. Plasma pharmacological study on Da Huang Zhe Chong capsule on platelet aggregation of normal person

    Institute of Scientific and Technical Information of China (English)

    WANG Dong-sheng; CHEN Fang-ping; XIAO Chang-jiang; HE Shi-lin; FU Bin; LI Xin; CAO Xing-yu; CHEN Yan; XIE Qin-zhi

    2005-01-01

    Objective To develop a plasma pharmacological method evaluates the effect of Da Huang Zhe Chong capsule on platelet aggregation and its mechanism, which is a representative Traditional Chinese Medicine Patent Prescription Promoting blood circulation by removing blood stasis. Methods Platelets specimens from healthy volunteers made serum and plasma with medicine, while platelet PRP were separated, which were divided into 8groups,i.e. auto-serum, allo-serum, serum with Da Huang Zhe Chong capsule , serum with aspirin, auto-plasma, plasma with Da Huang Zhe Chong capsule, plasma with aspirin, every group added to serum and plasma to hatch. After ADP and adrenalin were added into the specimens and hatched, the effects of specimens on platelet aggregation were observed. Results After ADP adrenalin were added, all the serum groups did not present platelet aggregation,while all the plasma group presented platelet aggregation. P1, P5, Pmax, t and TM have no significant difference (P>0. 05) between auto-plasma group and allo-plasma group induced by ADP and adrenalin. P1, P5, t and Pmax have significant differences (P<0. 01) and TM decreased significantly (P<0. 05) comparing plasma group with Da Huang Zhe Chong capsule and plasma group of aspirin to allo-plasma group. P1, t and Pmax have significant difference (P<0.05), and P5 and TM are simulate comparing plasma group with Da Huang Zhe Chong capsule to plasma group of aspirin. P1, P5, t and Pmax have significant differences (P<0. 01), P1, TM have also significant(P<0. 05), comparing plasma group of Da Huang Zhe Chong capsule with plasma of aspirin to allo-plasma group induced by adrenalin. P1 ,P5 and Pmax have significant differences (P<0.05), and t and Pmax are simulate comparing plasma group with Da Huang Zhe Chong capsule with plasma group of aspirin. Conclusion The serum pharmacological study is inappropriate to study platelet aggregation in vitro. The plasma pharmacological study is inappropriate to study

  1. Application of SLIM-MAUD: A test of an interactive computer-based method for organizing expert assessment of human performance and reliability: Volume 2, Appendices

    International Nuclear Information System (INIS)

    The US Nuclear Regulatory Commission (NRC) has been conducting a multiyear research program to investigate different methods for using expert judgments to estimate human error probabilities (HEPs) in nuclear power plants. One of the methods investigated, derived from multi-attribute utility theory, is the Success Likelihood Index Methodolocy implemented through Multi-Attribute Utility Decomposition (SLIM-MAUD). This report describes a systematic test application of the SLIM-MAUD methodology. The test application is evaluated on the basis of three criteria: practicality, acceptability, and usefulness. Volume I of this report represents an overview of SLIM-MAUD, describes the procedures followed in the test application, and provides a summary of the results obtained. Volume II consists of technical appendices to support in detail the materials contained in Volume I, and the users' package of explicit procedures to be followed in implementing SLIM-MAUD. The results obtained in the test application provide support for the application of SLIM-MAUD to a wide variety of applications requiring estimates of human errors

  2. To control and to be controlled – understanding the Arabidopsis SLIM1 function in sulfur deficiency through comprehensive investigation of the EIL protein family.

    Directory of Open Access Journals (Sweden)

    Anna eWawrzyńska

    2014-10-01

    Full Text Available SSLIM1, a member of the EIN3-like (EIL family of transcription factors in Arabidopsis, is the regulator of many sulfur-deficiency responsive genes. Among the five other proteins of the family, three regulate ethylene responses and two have unassigned functions. Contrary to the well-defined ethylene signaling, the pathway leading from sensing sulfate status to the activation of its acquisition via SLIM1 is completely unknown. SLIM1 binds to the 20 nt-long specific UPE-box sequence; however, it also recognizes the shorter TEIL sequence, unique for the whole EIL family. SLIM1 takes part in the upregulation and downregulation of various sulfur metabolism genes, but also it controls the degradation of glucosinolates under sulfur deficient conditions. Besides facilitating the increased flux through the sulfate assimilation pathway, SLIM1 induces microRNA395, specifically targeting ATP sulfurylases and a low-affinity sulfate transporter, SULTR2;1, thus affecting sulfate translocation to the shoot. Here, we briefly review the identification, structural characteristics and molecular function of SLIM1 from the perspective of the whole EIL protein family.

  3. Capsule irradiation tests of nuclear materials in HANARO

    International Nuclear Information System (INIS)

    Several irradiation capsule (3 instrumented and 2 non-instrumented capsules) were designed, fabricated and successfully irradiated in HANARO CT and IR2 test holes since the first non-instrumented capsule of 96M-01K. Those capsule were designed for the irradiation of the RPV (Reactor Pressure Vessel) material used in Korean PWR nuclear reactors. Various instrumentation techniques including temperature measuring and monitoring, gas controlling, micro-heating and neutron fluence monitoring were also developed for the capsule irradiation system. Through the irradiation tests, the obtained experience and design data will be effectively applied to the capsule design of other nuclear materials. (author)

  4. 单剂量与多剂量口服单硝酸异山梨酯缓释胶囊的人体生物等效性研究%Single -dose and multi -dose bioavailability of isosorbide -5 -mononitrate sustbilityained release capsules in Chinese healthy subjects

    Institute of Scientific and Technical Information of China (English)

    淳泽利; 所伟; 李静; 周子杰; 杜海燕; 仇琪; 赵颖; 刘有平; 刘文芳; 林阳; 杨克旭; 赵桂平; 鲁春艳; 谭莉; 张颖超; 吴伟

    2015-01-01

    Objective To compare the pharmacokinetic profiles between a new generic and a branded reference formulation of isosorbide -5 -mononitrate sustained release capsules , and to assess the bioequivalence of the two products in healthy Chinese male subjects.Methods Fifty subjects participated in the open -label, randomized -sequence, 2-way crossover study.Twenty-four subjects and 26 subjects were ran-domly assigned in a 1:1 ratio to receive single dose (50 mg) or multiple dose (50 mg, qd, 6 days) of the test or reference formulation , followed by a one -week washout period and administration of the alternate formulation , respectively.Serial blood samples were collected , and isosorbide -5 -mononitrate concentration in plasma was determined by LC-MS/MS.The relative bioavailability and related parameters of pharmacokinetics were calculated. Results The pharmacokinetic parameters of test formulation and the reference formulation after a single dose were as follows: Cmax were ( 554.18 ± 117.84 ) and (526.29 ±91.58 )μg· L-1; AUC0-t were ( 7834.21 ±1227.70 ) and (7658.86 ±927.74) h· μg· L-1 , respectively.The 90% confidential interval of Cmax and AUC0-t of test formulation were 99.82%-113.03%and 99.13%-106.43%of reference formulation , respectively.The pharmacokinetic parame-ters of test formulation and the reference formulation after multiple doses were as follows :Cmax were (612.96 ±171.32) and (527.12 ±114.36 ) μg · L-1; AUC0-t were ( 8408.71 ±1321.91 ) and ( 7781.88 ±1325.12 ) h · μg · L-1 , respectively.The 90% confidential interval of Cmax and AUC0-t of test formulation were 108.44% -122.17% and 105.35%-111.57% of reference formulation , respectively.The 90% confidence interval of Cmax and AUC0-t of isosorbide-5-mononitrate for the test formulation after single and multiple oral doses were fall within 70%-143%and 80%-125%of reference formulation.Conclusion The test formulation was considered bioequivalent to the reference formulation

  5. Production of 131I gelatin capsules

    International Nuclear Information System (INIS)

    Radioiodine (131I) hard-gelatin capsules are widely used for the diagnosis and treatment of various thyroid disorders. Until 1980 radioiodine was supplied by us as a liquid dosage. This proved to be a rather inconvenient form since it resulted in inaccurate dosing by the physicians and caused frequent contamination of the patients and the hospital personnel. In an attempt to overcome these problems we have designed and constructed a production facility for capsules in which 1311 is packaged. Because of the extreme precautions necessary in handling radioactive compounds, encapsulation of radioactive materials requires specifically designed production techniques, special instrumentation and unique quality control procedures that are not encountered in the standard capsule production processes in the pharmaceutical industry

  6. Intestinal preparation prior to capsule endoscopy administration

    Institute of Scientific and Technical Information of China (English)

    Vicente Pons Beltrán; Cristina Carretero; Bego(n)a Gonzalez-Suárez; I(n)aqui Fernández-Urien; Miguel Mu(n)oz Navas

    2008-01-01

    In order to have an adequate view of the whole small intestine during capsule endoscopy,the preparation recommended consists of a clear liquid diet and an overnight fast.However,visualization of the small bowel during video capsule endoscopy can be impaired by intestinal contents.To improve mucosal visualization,some authors have evaluated different regimens of preparation.There is no consensus about the necessity of intestinal preparation for capsule endoscopy and it should be interesting to develop adequate guidelines to improve its efficacy and tolerability.Moreover,the effect of preparation type (purgative) on intestinal transit time is not clear.Since a bowel preparation cannot definitively improve its visibility (and theoretically the yield of the test),it is not routinely recommended.

  7. Capsule endoscopy—A mechatronics perspective

    Science.gov (United States)

    Lin, Lin; Rasouli, Mahdi; Kencana, Andy Prima; Tan, Su Lim; Wong, Kai Juan; Ho, Khek Yu; Phee, Soo Jay

    2011-03-01

    The recent advances in integrated circuit technology, wireless communication, and sensor technology have opened the door for development of miniature medical devices that can be used for enhanced monitoring and treatment of medical conditions. Wireless capsule endoscopy is one of such medical devices that has gained significant attention during the past few years. It is envisaged that future wireless capsule endoscopies replace traditional endoscopy procedures by providing advanced functionalities such as active locomotion, body fluid/tissue sampling, and drug delivery. Development of energy-efficient miniaturized actuation mechanisms is a key step toward achieving this goal. Here, we review some of the actuators that could be integrated into future wireless capsules and discuss the existing challenges.

  8. Geriatric slim implants for complete denture wearers: clinical aspects and perspectives

    Directory of Open Access Journals (Sweden)

    Huard C

    2013-08-01

    Full Text Available Cedric Huard,2 Marion Bessadet,1,2 Emmanuel Nicolas,1,2 Jean-Luc Veyrune,1,21Clermont Université, Université d'Auvergne, Centre de Recherche en Odontologie Clinique, Clermont-Ferrand, France; 2CHU Clermont-Ferrand, Service d'Odontologie, Clermont-Ferrand, FranceBackground: Advances made in prevention have helped postpone complete edentulism in older patients. However, in the elderly, the physiological state reduces patients' ability to adapt to oral rehabilitation and degrades the patient's oral condition. Consequently, elderly edentulous subjects avoid many types of foods, which can lead to substantial nutritional consequences. Complete dentures retained by implants are, currently, the treatment of reference in prosthodontic mandibular rehabilitation. Indeed, the mandibular symphysis generally tolerates implantation, even when the mandible is strongly resorbed. However, in the elderly, implant rehabilitation is compromised by the complexity of the surgical protocol and possible postoperative complications. In this context, the use of geriatric "slim implants" (GSI offers an interesting alternative.Methods: In the present study, the surgical and prosthetic procedures for the use of GSI in a French dental hospital are presented. The objective was the stabilization of a complete mandibular denture in an elderly person, with the immediate implantation of four GSI.Results: The operating procedure was found to be less invasive, less expensive, simpler, and more efficient than the conventional procedure.Conclusion: The result strongly suggests that this protocol could be used systematically to treat complete edentulism in very elderly patients. Long-term monitoring and the evaluation of the reliability of this type of rehabilitation should be undertaken.Keywords: gerodontology, oral health, prostheses, mini-implant

  9. Slim edge studies, design and quality control of planar ATLAS IBL pixel sensors

    International Nuclear Information System (INIS)

    One of the four large experiments at the LHC at CERN is the ATLAS detector, a multi purpose detector. Its pixel detector, composed of three layers, is the innermost part of the tracker. As it is closest to the interaction point, it represents a basic part of the track reconstruction. Besides the requested high resolution one main requirement is the radiation hardness. In the coming years the radiation damage will cause deteriorations of the detector performance. With the planned increase of the luminosity, especially after the upgrade to the High Luminosity LHC, this radiation damage will be even intensified. This circumstance necessitates a new pixel detector featuring improved radiation hard sensors and read-out chips. The present shutdown of the LHC is already utilized to insert an additional b-layer (IBL) into the existing ATLAS pixel detector. The current n-in-n pixel sensor design had to be adapted to the new read-out chip and the module specifications. The new stave geometry requests a reduction of the inactive sensor edge. In a prototype wafer production all modifications have been implemented. The sensor quality control was supervised which led to the decision of the final sensor thickness. In order to evaluate the performance of the sensor chip assemblies with an innovative slim edge design, they have been operated in test beam setups before and after irradiation. Furthermore, the quality control of the planar IBL sensor wafer production was supervised from the stage of wafer delivery to that before the flip chip process to ensure a sufficient amount of functional sensors for the module production.

  10. Slim edge studies, design and quality control of planar ATLAS IBL pixel sensors

    Energy Technology Data Exchange (ETDEWEB)

    Wittig, Tobias

    2013-05-08

    One of the four large experiments at the LHC at CERN is the ATLAS detector, a multi purpose detector. Its pixel detector, composed of three layers, is the innermost part of the tracker. As it is closest to the interaction point, it represents a basic part of the track reconstruction. Besides the requested high resolution one main requirement is the radiation hardness. In the coming years the radiation damage will cause deteriorations of the detector performance. With the planned increase of the luminosity, especially after the upgrade to the High Luminosity LHC, this radiation damage will be even intensified. This circumstance necessitates a new pixel detector featuring improved radiation hard sensors and read-out chips. The present shutdown of the LHC is already utilized to insert an additional b-layer (IBL) into the existing ATLAS pixel detector. The current n-in-n pixel sensor design had to be adapted to the new read-out chip and the module specifications. The new stave geometry requests a reduction of the inactive sensor edge. In a prototype wafer production all modifications have been implemented. The sensor quality control was supervised which led to the decision of the final sensor thickness. In order to evaluate the performance of the sensor chip assemblies with an innovative slim edge design, they have been operated in test beam setups before and after irradiation. Furthermore, the quality control of the planar IBL sensor wafer production was supervised from the stage of wafer delivery to that before the flip chip process to ensure a sufficient amount of functional sensors for the module production.

  11. 核融合原型炉SlimCSの概念設計

    OpenAIRE

    飛田 健次; 西尾 敏; 榎枝 幹男; 中村 博文; 林 巧; 朝倉 伸幸; 宇藤 裕康; 谷川 博康; 西谷 健夫; 礒野 高明; 櫻井 真治; 栗田 源一; 林 孝夫; 大山 直幸; Liu, C

    2010-01-01

    発電実証だけでなく、最終的には経済性までを一段階で見通しうる核融合原型炉SlimCSの概念設計の成果を報告する。核融合の開発では、これまで、1990年に提案されたSSTR(Steady State Tokamak Reactor)が標準的な原型炉概念とされてきたが、本研究はSSTRより軽量化を図るため小規模な中心ソレノイドを採用して炉全体の小型化と低アスペクト比化を図り、高ベータ及び高楕円度(グリーンワルド密度限界を高めうる)を持つ炉心プラズマにより高出力密度を目指した。主要パラメータは、プラズマ主半径5.5m,アスペクト比2.6,楕円度2.0,規格化ベータ値4.3,核融合出力2.95GW,平均中性子壁負荷3MW/m2とした。この炉概念の技術的成立性を、プラズマ物理,炉構造,ブランケット,超伝導コイル,保守及び建屋の観点から検討した。...

  12. Application of SLIM-MAUD: a test of an interactive computer-based method for organizing expert assessment of human performance and reliability. Volume 1. Main report

    International Nuclear Information System (INIS)

    The US Nuclear Regulatory Commission has been conducting a multiyear research program to investigate different methods for using expert judgments to estimate human error probabilities in nuclear power plants. One of the methods investigated, derived from multi-attribute utility theory, is the Success Likelihood Index Methodology implemented through Multi-Attribute Utility Decomposition (SLIM-MAUD). This report describes a systematic test application of the SLIM-MAUD methodology. The test application is evaluated on the basis of three criteria: practicality, acceptability, and usefulness. Volume I of this report presents an overview of SLIM-MAUD, describes the procedures followed in the test application, and provides a summary of the results obtained. 14 refs

  13. A study of production/injection data from slim holes and large-diameter wells at the Takigami Geothermal Field, Kyushu, Japan

    Energy Technology Data Exchange (ETDEWEB)

    Garg, S.K. [Maxwell Federal Div., Inc., San Diego, CA (United States); Combs, J. [Geo-Hills Associates, Los Altos Hills, CA (United States); Azawa, Fumio [Idemitsu Kosan Co. Ltd., Tokyo (Japan); Gotoh, Hiroki [Idemitsu Oita Geothermal Co. Ltd., Oita (Japan)

    1996-11-01

    Production and injection data from nine slim holes and sixteen large-diameter wells at the Takigami Geothermal Field, Kyushu, Japan were analyzed in order to establish relationships (1) between injectivity and productivity indices, (2) between productivity/injectivity index and borehole diameter, and (3) between discharge capacity of slim holes and large-diameter wells. Results are compared with those from the Oguni and Sumikawa fields. A numerical simulator (WELBOR) was used to model the available discharge rate from Takigami boreholes. The results of numerical modeling indicate that the flow rate of large-diameter geothermal production wells with liquid feedzones can be predicted using data from slim holes. These results also indicate the importance of proper well design.

  14. Update on scribe–cleave–passivate (SCP) slim edge technology for silicon sensors: Automated processing and radiation resistance

    Energy Technology Data Exchange (ETDEWEB)

    Fadeyev, V., E-mail: fadeyev@ucsc.edu [Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA 95064 (United States); Ely, S.; Galloway, Z.; Ngo, J.; Parker, C.; Sadrozinski, H.F.-W. [Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA 95064 (United States); Christophersen, M.; Phlips, B.F. [U.S. Naval Research Laboratory, Code 7654, 4555 Overlook Avenue, Southwest Washington, DC 20375 (United States); Pellegrini, G.; Rafi, J.M.; Quirion, D. [Instituto de Microelectrónica de Barcelona, IMB-CNM-CSIC, Bellaterra, Barcelona (Spain); Dalla Betta, G.-F. [INFN and University of Trento, Via Sommarive, 14, 38123 Povo di Trento (Italy); Boscardin, M. [Fondazione Bruno Kessler, Via Sommarive, 18, 38123 Povo di Trento (Italy); Casse, G. [Department of Physics, University of Liverpool, O. Lodge Laboratory, Oxford Street, Liverpool L69 7ZE (United Kingdom); Gorelov, I.; Hoeferkamp, M.; Metcalfe, J.; Seidel, S. [Department of Physics and Astronomy, University of New Mexico, MSC 07 4220, 1919 Lomas Boulevard NE, Albuquerque, NM 87131 (United States); Gaubas, E.; Ceponis, T. [Institute of Applied Research, Vilnius University, Sauletekio 9, LT-10222 Vilnius (Lithuania); and others

    2014-11-21

    We pursue scribe–cleave–passivate (SCP) technology for making “slim edge” sensors. The goal is to reduce the inactive region at the periphery of the devices while maintaining their performance. In this paper we report on two aspects of the current efforts. The first one involves fabrication options for mass production. We describe the automated cleaving tests and a simplified version of SCP post-processing of n-type devices. Another aspect is the radiation resistance of the passivation. We report on the radiation tests of n- and p-type devices with protons and neutrons.

  15. Update on scribe–cleave–passivate (SCP) slim edge technology for silicon sensors: Automated processing and radiation resistance

    International Nuclear Information System (INIS)

    We pursue scribe–cleave–passivate (SCP) technology for making “slim edge” sensors. The goal is to reduce the inactive region at the periphery of the devices while maintaining their performance. In this paper we report on two aspects of the current efforts. The first one involves fabrication options for mass production. We describe the automated cleaving tests and a simplified version of SCP post-processing of n-type devices. Another aspect is the radiation resistance of the passivation. We report on the radiation tests of n- and p-type devices with protons and neutrons

  16. NSRR high-temperature high-pressure capsule

    International Nuclear Information System (INIS)

    This report describes a high temperature, high pressure capsule (HT-HP capsule) developed for NSRR (Nuclear Safety Research Reactor) in JAERI. To perform reactivity accident tests under power reactor operating conditions, the capsule is designed to simulate a high temperature, high pressure atmosphere of BWR or PWR. Out-pile and in-pile performance tests of the capsule made by December 1978 showed its design specifications had been met. (author)

  17. Floating anterior lens capsule: an unusual case of true exfoliation

    OpenAIRE

    Riffle, John

    2010-01-01

    A rare case of delamination and replication of the anterior lens capsule into prominent floating folds in the anterior chamber approximately 55 years after a penetrating injury to the eye and anterior lens capsule is reported. Classically, true exfoliation of the anterior lens capsule has been reported in individuals who have been exposed to intense heat over a prolonged period. However, more recently cases of true exfoliation of the anterior lens capsule have been reported in patients who ha...

  18. ADHESIVE CAPSULITIS: USE THE EVIDENCE TO INTEGRATE YOUR INTERVENTIONS

    OpenAIRE

    Page, Phil; Labbe, Andre

    2010-01-01

    Frozen shoulder syndrome, clinically known as adhesive capsulitis, is a painful and debilitating condition affecting up to 5% of the population. Adhesive capsulitis is considered fibrosis of the glenohumeral joint capsule with a chronic inflammatory response. Patients experience pain, limited range of motion, and disability generally lasting anywhere from 1 to 24 months. The purpose of this clinical suggestion is to review the pathophysiolgy of adhesive capsulitis and discuss physical therapy...

  19. Intrauterine fertilization capsules--a clinical trial

    DEFF Research Database (Denmark)

    Lenz, S; Lindenberg, S; Sundberg, K;

    1991-01-01

    Treatment of 26 women with tubal infertility was attempted using intrauterine capsules loaded with oocytes and spermatozoa. The stimulation protocol was as used for in vitro fertilization and embryo transfer and consisted of short-term use of Buserelin, human menopausal gonadotropin, and human ch...

  20. Reciprocal Teaching. Information Capsule. Volume 0609

    Science.gov (United States)

    Blazer, Christie

    2007-01-01

    Reciprocal teaching is an instructional approach designed to increase students' reading comprehension at all grade levels and in all subject areas. Students are taught cognitive strategies that help them construct meaning from text and simultaneously monitor their reading comprehension. This Information Capsule summarizes reciprocal teaching's…

  1. Design of Endoscopic Capsule With Multiple Cameras.

    Science.gov (United States)

    Gu, Yingke; Xie, Xiang; Li, Guolin; Sun, Tianjia; Wang, Dan; Yin, Zheng; Zhang, Pengfei; Wang, Zhihua

    2015-08-01

    In order to reduce the miss rate of the wireless capsule endoscopy, in this paper, we propose a new system of the endoscopic capsule with multiple cameras. A master-slave architecture, including an efficient bus architecture and a four level clock management architecture, is applied for the Multiple Cameras Endoscopic Capsule (MCEC). For covering more area of the gastrointestinal tract wall with low power, multiple cameras with a smart image capture strategy, including movement sensitive control and camera selection, are used in the MCEC. To reduce the data transfer bandwidth and power consumption to prolong the MCEC's working life, a low complexity image compressor with PSNR 40.7 dB and compression rate 86% is implemented. A chipset is designed and implemented for the MCEC and a six cameras endoscopic capsule prototype is implemented by using the chipset. With the smart image capture strategy, the coverage rate of the MCEC prototype can achieve 98% and its power consumption is only about 7.1 mW. PMID:25376042

  2. 21 CFR 520.2345a - Tetracycline hydrochloride capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Tetracycline hydrochloride capsules. 520.2345a... Tetracycline hydrochloride capsules. (a) Specifications. Each capsule contains 50, 100, 125, 250, or 500 milligrams (mg) tetracycline hydrochloride. (b) Sponsor. See sponsors in § 510.600(c) of this chapter for...

  3. 21 CFR 872.3110 - Dental amalgam capsule.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with...

  4. 21 CFR 520.446 - Clindamycin capsules and tablets.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Clindamycin capsules and tablets. 520.446 Section... capsules and tablets. (a) Specifications—(1) Each capsule contains the equivalent of 25, 75, 150, or 300 milligrams (mg) clindamycin as the hydrochloride salt. (2) Each tablet contains the equivalent of 25, 75,...

  5. 21 CFR 520.1804 - Piperazine phosphate capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Piperazine phosphate capsules. 520.1804 Section... phosphate capsules. (a) Specifications. Each capsule contains 120, 300, or 600 milligrams of piperazine phosphate monohydrate. (b) Sponsor. See No. 051311 in § 510.600(c) of this chapter. (c) Conditions of...

  6. Ingestible capsule for remote controlled release of a substance

    DEFF Research Database (Denmark)

    2014-01-01

    The application relates to an ingestible capsule (102) for delivery of a substance e.g. a pharmaceutical drug, to a human or animal. The ingestible capsule comprises a capsule wall structure (202) forming a substantially sealed reservoir or lumen holding the substance (204). An electrical resonance...

  7. 21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin sodium monohydrate equivalent to 50, 100, 200, or 500 milligrams of dicloxacillin. (b) Sponsor. See No. 000856...

  8. Clinical effects of a standardized Chinese herbal remedy, Qili Qiangxin, as an adjuvant treatment in heart failure: systematic review and meta-analysis

    OpenAIRE

    Sun, Jin; Zhang, Kang; Xiong, Wen-jing; Yang, Guo-Yan; Zhang, Yun-Jiao; Wang, Cong-Cong; Lai, Lily; Han, Mei; Ren, Jun; Lewith, George; Liu, Jian-ping

    2016-01-01

    Background Qili Qiangxin capsule is a standardized Chinese herbal treatment that is commonly used in China for heart failure (HF) alongside conventional medical care. In 2014, Chinese guidelines for the treatment of chronic HF highlighted Qili Qiangxin capsules as a potentially effective medicine. However, there is at present no high quality review to evaluate the effects and safety of Qili Qiangxin for patients with HF. Methods We conducted a systematic review and meta-analysis and followed ...

  9. Slim by design: serving healthy foods first in buffet lines improves overall meal selection.

    Directory of Open Access Journals (Sweden)

    Brian Wansink

    Full Text Available OBJECTIVE: Each day, tens of millions of restaurant goers, conference attendees, college students, military personnel, and school children serve themselves at buffets--many being all-you-can-eat buffets. Knowing how the food order at a buffet triggers what a person selects could be useful in guiding diners to make healthier selections. METHOD: The breakfast food selections of 124 health conference attendees were tallied at two separate seven-item buffet lines (which included cheesy eggs, potatoes, bacon, cinnamon rolls, low-fat granola, low-fat yogurt, and fruit. The food order between the two lines was reversed (least healthy to most healthy, and vise-versa. Participants were randomly assigned to choose their meal from one line or the other, and researchers recorded what participants selected. RESULTS: With buffet foods, the first ones seen are the ones most selected. Over 75% of diners selected the first food they saw, and the first three foods a person encountered in the buffet comprised 66% of all the foods they took. Serving the less healthy foods first led diners to take 31% more total food items (p<0.001. Indeed, diners in this line more frequently chose less healthy foods in combinations, such as cheesy eggs and bacon (r = 0.47; p<0.001 or cheesy eggs and fried potatoes (r= 0.37; p<0.001. This co-selection of healthier foods was less common. CONCLUSIONS: Three words summarize these results: First foods most. What ends up on a buffet diner's plate is dramatically determined by the presentation order of food. Rearranging food order from healthiest to least healthy can nudge unknowing or even resistant diners toward a healthier meal, helping make them slim by design. Health-conscious diners, can proactively start at the healthier end of the line, and this same basic principle of "first foods most" may be relevant in other contexts - such as when serving or passing food at family dinners.

  10. Symptomatic Patency Capsule Retention in Suspected Crohn's Disease

    DEFF Research Database (Denmark)

    Rasmussen, Bjørn; Nathan, Torben; Jensen, Michael Dam

    2016-01-01

    The main limitation of capsule endoscopy is the risk of capsule retention. In patients with suspected Crohn's disease, however, this complication is rare, and if a small bowel stenosis is not reliably excluded, small bowel patency can be confirmed with the Pillcam patency capsule. We present two...... patients examined for suspected Crohn's disease who experienced significant symptoms from a retained patency capsule. Both patients had Crohn's disease located in the terminal ileum. In one patient, the patency capsule caused abdominal pain and vomiting and was visualized at magnetic resonance enterography...

  11. Yangjing Capsule Ameliorates Spermatogenesis in Male Mice Exposed to Cyclophosphamide

    Directory of Open Access Journals (Sweden)

    Hongle Zhao

    2015-01-01

    Full Text Available Yangjing capsule (YC, a traditional Chinese compound herbal preparation, has been proven as an effective drug to improve spermatogenesis in clinical practice. However, its pharmacological mechanisms were not fully clarified. This study was designed to investigate the protective effects of YC on spermatogenesis in the mouse model of spermatogenesis dysfunction induced by cyclophosphamide (CP. The administration of YC significantly increased the epididymal index, sperm count, and sperm motility of model mice. Histopathological changes demonstrated that CP caused obvious structural damage to testis, which were reversed by the administration of YC. Results from TUNEL assay showed that treatment with YC dramatically decreased the apoptosis of spermatogenic cell induced by CP. Moreover, YC treatment could inhibit the mRNA and protein expression of Bax to Bcl-2 and also raised expression of AR at both mRNA and protein levels. These data suggest that YC might ameliorate spermatogenesis in male mice exposed to CP through inhibiting the apoptosis of spermatogenic cell and enhancing the actions of testosterone in spermatogenesis.

  12. 米屈肼胶囊在中国健康志愿者体内的耐受性和药动学%Pharmacokinetics and tolerability of oral mildronate capsule administered in single and multiple-dose in healthy Chinese subjects

    Institute of Scientific and Technical Information of China (English)

    程钢; 彭文兴; 朱荣华; 周述香; 曾玲

    2013-01-01

    /2和MRT0-24与单次给药500mg剂量给相比明显延长,AUCSS0-8与单次给药500 mg剂量组的AUG0-x相比约增加了60%.结论:米屈肼在中国健康受试者中耐受性良好.单次口服米屈肼胶囊250,500,1000,1 250 mg和1 500 mg后,呈非线性药动学特征,多次给药后在人体内有明显的蓄积作用.根据多剂量组的研究结果,其t1/2延长为14.6h,对于长期用药的患者推荐每日服药2次.%OBJECTIVE To assess the pharmacokinetics and tolerance of single and multiple-dose mildronate in healthy Chinese subjects. METHODS Forty healthy subjects were divided into five groups (each group consisting 4 males and 4 females) by randomized blind design. These five groups were administered single-dose of 250, 500, 1 000, 1 250 or 1 500 mg mildronate capsule respectively for tolerablity assessment and single-dose pharmacokinetics profile. After one week wash-out period, the subjects of 500 mg dose group in single-dose pharmacokinetics study were enrolled for a multiple-dose pharmacokinetics profile. Eight volunteers were received mildronate at 500 mg every 8 h (q 8 h) for consecutive 13 days. Safety and tolerance were evaluated by monitoring adverse events and laboratory parameters and pharmacokinetics were assessed by determining mildronate concentrations with a validated HPLC-MS method. RESULTS No serious adverse events occurred. After single dose oral administration, the main pharmacokinetic parameters found for mildronate at doses of 250, 500. 1 000, 1 250 mg and 1 500 mg were as follows: t max were (1. 2 ± 0. 3) , (1. 0 ± 0. 4), (1. 2 ± 0. 6), (1. 2 ± 0. 4)h and (1. 0 ± 0. 4)h, respectively; t1/2 were (3. 6 ± 0. 7), (5. 3± 1.2), (6. 1 ±0. 5), (6. 1 ±0. 4)h and (6. 6 + 0. 9)h;MRT0-24 were (7. 3 ±0. 9),(8. 4± 1. 1),(8. 7± 1. 5),(8. 7± 0.7) hand (9. 0± l. l)h;V/F were (39 ± 7). (54 ± 12), (66± 9), (68 ±7) L and (71 ±14) L;CL/F were (7. 6 ± 1. 2), (7. 2 ±1. 1),(7. 5±1. 1),(7. 8±1.0)L·h-1 and (7. 5 ± 1.3) L

  13. Capsule- and disk-filter procedure

    Science.gov (United States)

    Skrobialowski, Stanley C.

    2016-01-01

    Capsule and disk filters are disposable, self-contained units composed of a pleated or woven filter medium encased in a polypropylene or other plastic housing that can be connected inline to a sample-delivery system (such as a submersible or peristaltic pump) that generates sufficient pressure (positive or negative) to force water through the filter. Filter media are available in several pore sizes, but 0.45 µm is the pore size used routinely for most studies at this time. Capsule or disk filters (table 5.2.1.A.1) are required routinely for most studies when filtering samples for trace-element analyses and are recommended when filtering samples for major-ion or other inorganic-constituent analyses.

  14. Resorcinarenes are hexameric capsules in solution

    OpenAIRE

    Evan-Salem, Tamar; Baruch, Inbal; Avram, Liat; Cohen, Yoram; Palmer, Liam C.; Rebek, Julius

    2006-01-01

    The host–guest complexes of resorcin[4]arenes with small molecules in organic solutions are examined using modern NMR spectroscopic methods. The complexation of glutaric acid and β-methyl d-glucopyranoside in chloroform were investigated through 2D COSY, 2D NOESY, 1D NOE, and diffusion-ordered NMR spectroscopy (DOSY) techniques. These methods indicate that the complex is a self-assembled capsule composed of six resorcinarenes that surround six guest molecules of glutaric acid or three molecul...

  15. Dissociated Prostate Regeneration under the Renal Capsule.

    Science.gov (United States)

    Zong, Yang; Goldstein, Andrew S; Witte, Owen N

    2015-11-01

    Tissue recombination models are useful for studying cancer initiation, progression, and metastasis. They also provide an in vivo environment in which to investigate the functional role of stem cells in tissue repair. In this protocol, we describe in detail the dissociated prostate regeneration assay. Dissociated adult murine prostate cells are combined with embryonic urogenital sinus mesenchymal cells and implanted under the renal capsule. Morphological tissue structures with appropriate epithelial-stroma interactions are reconstituted in the grafts. PMID:26527760

  16. Experimental models for posterior capsule opacification research.

    Science.gov (United States)

    Wormstone, Ian Michael; Eldred, Julie Ann

    2016-01-01

    Millions of people worldwide are blinded due to cataract formation. At present the only means of treating a cataract is through surgical intervention. A modern cataract operation involves the creation of an opening in the anterior lens capsule to allow access to the fibre cells, which are then removed. This leaves in place a capsular bag that comprises the remaining anterior capsule and the entire posterior capsule. In most cases, an intraocular lens is implanted into the capsular bag during surgery. This procedure initially generates good visual restoration, but unfortunately, residual lens epithelial cells undergo a wound-healing response invoked by surgery, which in time commonly results in a secondary loss of vision. This condition is known as posterior capsule opacification (PCO) and exhibits classical features of fibrosis, including hyperproliferation, migration, matrix deposition, matrix contraction and transdifferentiation into myofibroblasts. These changes alone can cause visual deterioration, but in a significant number of cases, fibre differentiation is also observed, which gives rise to Soemmering's ring and Elschnig's pearl formation. Elucidating the regulatory factors that govern these events is fundamental in the drive to develop future strategies to prevent or delay visual deterioration resulting from PCO. A range of experimental platforms are available for the study of PCO that range from in vivo animal models to in vitro human cell and tissue culture models. In the current review, we will highlight some of the experimental models used in PCO research and provide examples of key findings that have resulted from these approaches. PMID:25939555

  17. Capsule endoscopy: Present status and future expectation

    Science.gov (United States)

    Goenka, Mahesh K; Majumder, Shounak; Goenka, Usha

    2014-01-01

    Video capsule endoscopy (CE) since its introduction 13 years back, has revolutionized our approach to small intestinal diseases. Obscure gastrointestinal bleed (OGIB) continues to be the most important indication for CE with a high sensitivity, specificity as well as positive and negative predictive values. It is best performed during ongoing bleed or immediately thereafter. Overt OGIB has a higher diagnostic yield than occult OGIB. However, even in iron deficiency anemia, CE is emerging as important investigation after initial negative work up. In suspected Crohn’s disease (CD), CE has been shown superior to traditional imaging and endoscopic technique and should be considered after a negative ileocolonoscopy. Although CE has also been used for evaluating established CD, a high capsule retention rate precludes its use ahead of cross-sectional imaging. Celiac disease, particularly where gastro-duodenoscopy cannot be performed or is normal, can also be investigated by CE. Small bowel tumor, hereditary polyposis syndrome, and non-steroidal anti-inflammatory drugs induced intestinal damage are other indications for CE. Capsule retention is the only significant adverse outcome of CE and occurs mostly in presence of intestinal obstruction. This can be prevented by use of Patency capsule prior to CE examination. Presence of cardiac pacemaker and intracardiac devices continue to be relative contraindications for CE, though data do not suggest interference of CE with these devices. Major limitations of CE today include failure to control its movement from outside, inability of CE to acquire tissue for diagnosis, and lack of therapeutic help. With ongoing interesting and exciting developments taking place in these areas, these issues would be solved in all probability in near future. CE has the potential to become one of the most important tools in diagnostic and possibly in the therapeutic field of gastrointestinal disorder. PMID:25110430

  18. Guideline for Capsule Endoscopy: Obscure Gastrointestinal Bleeding

    OpenAIRE

    Shim, Ki-Nam; Moon, Jeong Seop; Chang, Dong Kyung; Do, Jae Hyuk; Kim, Ji Hyun; Min, Byung Hoon; Jeon, Seong Ran; Kim, Jin-Oh; Choi, Myung-Gyu; ,

    2013-01-01

    Capsule endoscopy (CE) is considered as a noninvasive and reliable diagnostic tool of examining the entire small bowel. CE has been performed frequently at many medical centers in South Korea; however, there is no evidence-based CE guideline for adequate diagnostic approaches. To provide accurate information and suggest correct testing approaches for small bowel disease, the guideline on CE was developed by the Korean Gut Image Study Group, a part of the Korean Society of Gastrointestinal End...

  19. Primary synovial osteochondromatosis presenting as constrictive capsulitis

    International Nuclear Information System (INIS)

    Primary synovial chondromatosis of the joints can present as capsular constriction with peri-articular osteopenia. This rare presentation is highlighted in three cases (two hips and one shoulder). The diagnosis in all the patients was made on arthrography and/or MRI/CT and was confirmed histologically. Synovial chondromatosis should be considered in patients with this presentation. Arthrography is the best imaging modality to confirm the cause (synovial chondromatosis) and effect (constrictive capsulitis). (orig.)

  20. Collapse of experimental capsules under external pressure

    Energy Technology Data Exchange (ETDEWEB)

    Simonen, F.A.; Shippell, R.J. Jr.

    1980-01-01

    Stress analyses and developmental tests of capsules fabricated from thick-walled tubing were performed for an external pressure design condition. In the design procedure no credit was taken for the expected margin in pressure between yielding of the capsule wall and catastrophic collapse or flattening. In tests of AISI-1018 low carbon steel capsules, a significant margin was seen between yield and collapse pressure. However, the experimental yield pressures were significantly below predictions, essentially eliminating the safety margin present in the conservative design approach. The differences between predictions and test results are attributed to deficiencies in the plasticity theories commonly in use for engineering stress analyses. The results of this study show that the von Mises yield condition does not accurately describe the yield behavior of the AISI-1018 steel tubing material for the triaxial stress conditions of interest. Finite element stress analyses successfully predicted the transition between uniform inward plastic deformation and ovalization that leads to catastrophic collapse. After adjustments to correct for the unexpected yield behavior of the tube material, the predicted pressure-deflection trends were found to follow the experimental data.

  1. Collapse of experimental capsules under external pressure

    International Nuclear Information System (INIS)

    Stress analyses and developmental tests of capsules fabricated from thick-walled tubing were performed for an external pressure design condition. In the design procedure no credit was taken for the expected margin in pressure between yielding of the capsule wall and catastrophic collapse or flattening. In tests of AISI-1018 low carbon steel capsules, a significant margin was seen between yield and collapse pressure. However, the experimental yield pressures were significantly below predictions, essentially eliminating the safety margin present in the conservative design approach. The differences between predictions and test results are attributed to deficiencies in the plasticity theories commonly in use for engineering stress analyses. The results of this study show that the von Mises yield condition does not accurately describe the yield behavior of the AISI-1018 steel tubing material for the triaxial stress conditions of interest. Finite element stress analyses successfully predicted the transition between uniform inward plastic deformation and ovalization that leads to catastrophic collapse. After adjustments to correct for the unexpected yield behavior of the tube material, the predicted pressure-deflection trends were found to follow the experimental data

  2. Hot cell examination on the surveillance capsule and HANARO capsule in IMEF

    International Nuclear Information System (INIS)

    For the maintenance of integrity and safety of pressurizer of commercial power plant until its life span, it is required by US NRC 10CFR50 APP. G and H and ASTM E185-94 to periodically monitor irradiation embrittlement by neutron irradiation. In order to accomplished the requirement reactor operator has been carrying out the test by extracting the monitoring capsule embeded in reactor during the period of planned preventive maintenance. In relation to this irradiation samples are being used for prediction of reactor vessel life span and reactor vessel's adjusted reference temperature by irradiation of neutron flux enough to reach to end of life span. And also irradiation capsules with and without instrumentation are used for R and D on nuclear materials. Each capsule contains high radioactivity, therefore, post irradiation examination has to be handled by all means in the hot cell. The facility available for this purpose is Irradiated material examination facility (IMEF) to handle such works as capsule receiving, capsule cut and dismantling, sample classification, various examination, and finally development and improvement of examination equipment and instrumentation. (Hong, J. S.)

  3. Manufacturing Facility To Open Aluminium Capsule Cupusing in Hydraulic Rabbit System

    International Nuclear Information System (INIS)

    Long time capsule was using in hydraulic rabbit system RSG-GAS is made from polyethylene. This capsule has short time irradiation (maximum 1 hour). For target was needed long irradiation, we use new capsule made from aluminium. Capsule aluminium is consisting of capsule body and capsule cup. Because aluminium capsule has higher activity than polyethylene capsule, so to open this capsule must be doing in the hot cell rabbit. For opening capsule cup needed new facility. Main component of this this facility are support for motor, support for weight, DC motor with low speed about rpm, rod and weight, 2 clamps and control system. Position of this facility is horizontal. To operating this facility one of clamp handle capsule body and the other clamp handle capsule cup. Using DC motor, the capsule body is turned and capsule cup out from body

  4. Chinese Cooking.

    Science.gov (United States)

    Kane, Tony

    This unit, intended for secondary level students, is a general introduction to Chinese cooking. It is meant to inform students about the origins of Chinese cooking styles in their various regional manifestations, and it can be used to discuss how and why different cultures develop different styles of cooking. The first part of the unit, adapted…

  5. Constraining weakly interacting slim particles with a massive star and in the laboratory

    International Nuclear Information System (INIS)

    This doctoral thesis is devoted to constraining the allowed parameter space of weakly interacting slim particles (WISPs). WISPs are predicted by many extensions of the Standard Model of Particle Physics (SM): The Peccei-Quinn solution of the strong CP-problem of quantum chromo dynamics requires the existence of an axion; some embeddings of the SM into string theories predict a large number of axion-like particles (ALPs), the so called axi-verse, and hidden photons (HPs). Cosmological and astrophysical observables are sensitive to the existence of WISPs. Measurements of these observables allow to constrain the allowed WISP parameter space. In addition dedicated laboratory based experiments exist. Although the parameter space excluded by these experiments is generally smaller than the regions excluded by measurements of cosmological or astrophysical observables, the results from these experiment are valuable complements to these measurements because they are less model dependent. In this thesis, I present my work that helps to constrain the WISP parameter space in two ways: First, the existence of ALPs implies their production in stellar cores. The oscillation of ALPs with photons in the galactic magnetic field (GMF) suggest an X-ray flux from red supergiant (RSG) stars. RSGs are expected to emit no X-rays if ALPs do not exist. An upper limit for the X-ray count rate from the nearby RSG α-Ori (Betelgeuse) is estimated from observations of α-Ori with the Chandra X-ray Telescope. The interior of α-Ori is modelled with the ''Evolve ZAMS'' code. Based on this, the corresponding ALP production rate is calculated. Using current estimates of the value of the regular component of the GMF, the resulting X-ray flux density at Earth from ALP-photon oscillations and the corresponding count rates with the Chandra instruments are calculated. Comparison of this estimate with the upper limit from the Chandra measurements allows to exclude values of the ALP-photon coupling above 2

  6. Role of shocks and mix caused by capsule defects

    Science.gov (United States)

    Bradley, P. A.; Cobble, J. A.; Tregillis, I. L.; Schmitt, M. J.; Obrey, K. D.; Glebov, V.; Batha, S. H.; Magelssen, G. R.; Fincke, J. R.; Hsu, S. C.; Krasheninnikova, N. S.; Murphy, T. J.; Wysocki, F. J.

    2012-09-01

    An Eulerian code with a turbulent mix model is used to model a set of plastic (CH) ablator capsules with and without equatorial grooves. The "perfect" capsule results were used to calibrate simulations of capsules with equatorial grooves of different depths that provided information on increasingly perturbed implosions. Simulations with a turbulence model were able to calculate the same yield over mix (YOM) ratio (experiment/mix simulation) of 0.2 to 0.3 for thin (8-μm thick) and thick shell (15-μm thick) capsules with no grooves and thin capsules with shallow grooves. When the capsules have deep grooves, the YOM ratio increases to greater than unity, probably because the deformed shocks focus too strongly on the symmetry axis in our two-dimensional simulations. This is supported by a comparison of simulated and experimental x-ray images.

  7. The motion of a deforming capsule through a corner

    CERN Document Server

    Zhu, Lailai

    2014-01-01

    A three-dimensional deformable capsule convected through a channel/duct with a corner is studied via numerical simulations using an accelerated boundary integral method adapted to general geometries. A global spectral method is adopted to resolve the dynamics of the capsule's membrane developing elastic tensions according to the Neo-Hookean constitutive law and bending moments in an inertialess flow. The simulations show that the trajectory of the capsule closely follows the underlying streamlines and the deformation of the capsule induces an anti-clockwise rotation of its material points with respect to the travelling direction. The surface area, principle tension and elastic energy of the capsule increase around the corner. Their temporal evolutions are characterised by a clear phase delay and the loss of time-reversal symmetry of Stokes flow due to the elasticity of membrane. The capsule centroid velocity decreases approaching the corner as the mean flow does while a velocity overshoot is observed past the...

  8. Capsule development and utilization for material irradiation tests

    International Nuclear Information System (INIS)

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules

  9. A Review of Locomotion Systems for Capsule Endoscopy.

    Science.gov (United States)

    Liu, Lejie; Towfighian, Shahrzad; Hila, Amine

    2015-01-01

    Wireless capsule endoscopy for gastrointestinal (GI) tract is a modern technology that has the potential to replace conventional endoscopy techniques. Capsule endoscopy is a pill-shaped device embedded with a camera, a coin battery, and a data transfer. Without a locomotion system, this capsule endoscopy can only passively travel inside the GI tract via natural peristalsis, thus causing several disadvantages such as inability to control and stop, and risk of capsule retention. Therefore, a locomotion system needs to be added to optimize the current capsule endoscopy. This review summarizes the state-of-the-art locomotion methods along with the desired locomotion features such as size, speed, power, and temperature and compares the properties of different methods. In addition, properties and motility mechanisms of the GI tract are described. The main purpose of this review is to understand the features of GI tract and diverse locomotion methods in order to create a future capsule endoscopy compatible with GI tract properties. PMID:26292162

  10. Role of shocks and mix caused by capsule defects

    International Nuclear Information System (INIS)

    An Eulerian code with a turbulent mix model is used to model a set of plastic (CH) ablator capsules with and without equatorial grooves. The “perfect” capsule results were used to calibrate simulations of capsules with equatorial grooves of different depths that provided information on increasingly perturbed implosions. Simulations with a turbulence model were able to calculate the same yield over mix (YOM) ratio (experiment/mix simulation) of 0.2 to 0.3 for thin (8-μm thick) and thick shell (15-μm thick) capsules with no grooves and thin capsules with shallow grooves. When the capsules have deep grooves, the YOM ratio increases to greater than unity, probably because the deformed shocks focus too strongly on the symmetry axis in our two-dimensional simulations. This is supported by a comparison of simulated and experimental x-ray images.

  11. Capsule development and utilization for material irradiation tests

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N. [and others

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules.

  12. Anterior capsule tear after laser iridotomy complicating phacoemulsification

    OpenAIRE

    Vivien Cherng Hui, Yip; Sanjay, Srinivasan; Benjamin Chong-Ming, Chang

    2011-01-01

    A 70-year-old Indian lady had a history of bilateral laser peripheral iridotomy (LPI) for primary angle closure. Subsequently she developed cataract in both the eyes. Right eye cataract surgery was complicated by an anterior capsule rupture, which was discovered intra-operatively at the site of the LPI. Trypan blue was used to stain the anterior capsule to delineate the anterior capsule defect. An attempt at continuous curvilinear capsulorhexis was unsuccessful, and the anterior capsulotomy w...

  13. Fibrous Calcareous Concretions in the Capsules of Human Pineal Glands

    OpenAIRE

    Kodaka Tetsuo; Mori Ryoichi; Ezure Hiromitsu; Ito Junji; Otsuka Naruhito

    2013-01-01

    We examined calcareous concretions in the capsule of 15 human pineal glands containing a large amount of the concretions in the matrix. The capsule concretions, brown to blackish-brown in color and/or translucent, were smaller than the matrix concretions, which were yellowish-white. The matrix concretions showed the typical mulberry-shaped overall appearance with scallop-shaped concentric laminations of non-fibrous structures, but the capsule concretions, which also contained Ca and P, showed...

  14. Scanning Parameter Space for NIF capsules in HYDRA

    Energy Technology Data Exchange (ETDEWEB)

    Fetterman, A; Herrmann, M C; Haan, S

    2004-11-10

    The authors have implemented an automated pulse shaper for NIF capsules in HYDRA. We have developed the infrastructure to do scans using the automatic pulse shaper across any n-dimensions of capsule parameter space. Using this infrastructure, we have performed several scans examining parameters for uniformly doped Beryllium capsules. To coordinate more closely with the anticipated experimental shock timing strategy, we have started to develop an automated pulse shaper which uses planar geometry and liquid DD.

  15. Small intestinal model for electrically propelled capsule endoscopy

    Directory of Open Access Journals (Sweden)

    Woo Sang Hyo

    2011-12-01

    Full Text Available Abstract The aim of this research is to propose a small intestine model for electrically propelled capsule endoscopy. The electrical stimulus can cause contraction of the small intestine and propel the capsule along the lumen. The proposed model considered the drag and friction from the small intestine using a thin walled model and Stokes' drag equation. Further, contraction force from the small intestine was modeled by using regression analysis. From the proposed model, the acceleration and velocity of various exterior shapes of capsule were calculated, and two exterior shapes of capsules were proposed based on the internal volume of the capsules. The proposed capsules were fabricated and animal experiments were conducted. One of the proposed capsules showed an average (SD velocity in forward direction of 2.91 ± 0.99 mm/s and 2.23 ± 0.78 mm/s in the backward direction, which was 5.2 times faster than that obtained in previous research. The proposed model can predict locomotion of the capsule based on various exterior shapes of the capsule.

  16. Increasing Z-pinch vacuum hohlraum capsule coupling efficiency.

    Energy Technology Data Exchange (ETDEWEB)

    Callahan, Debbie (LLNL); Vesey, Roger Alan; Cochrane, Kyle Robert (KTech); Nikroo, A. (General Atomics); Bennett, Guy R.; Schroen, Diana Grace (Schafer); Ruggles, Laurence E.; Porter, John L.; Streit, Jon (Schafer); Mehlhorn, Thomas Alan; Cuneo, Michael Edward

    2004-11-01

    Symmetric capsule implosions in the double-ended vacuum hohlraum (DEH) on Z have demonstrated convergence ratios of 14-21 for 2.15-mm plastic ablator capsules absorbing 5-7 kJ of x-rays, based on backlit images of the compressed ablator remaining at peak convergence [1]. Experiments with DD-filled 3.3-mm diameter capsules designed to absorb 14 kJ of x-rays have begun as an integrated test of drive temperature and symmetry, complementary to thin-shell symmetry diagnostic capsules. These capsule implosions are characterized by excellent control of symmetry (< 3% time-integrated), but low hohlraum efficiency (< 2%). Possible methods to increase the capsule absorbed energy in the DEH include mixed-component hohlraums, large diameter foam ablator capsules, transmissive shine shields between the z-pinch and capsule, higher spoke electrode x-ray transmission, a double-sided power feed, and smaller initial radius z-pinch wire arrays. Simulations will explore the potential for each of these modifications to increase the capsule coupling efficiency for near-term experiments on Z and ZR.

  17. Increasing Z-pinch vacuum hohlraum capsule coupling efficiency

    International Nuclear Information System (INIS)

    Symmetric capsule implosions in the double-ended vacuum hohlraum (DEH) on Z have demonstrated convergence ratios of 14-21 for 2.15-mm plastic ablator capsules absorbing 5-7 kJ of x-rays, based on backlit images of the compressed ablator remaining at peak convergence (1). Experiments with DD-filled 3.3-mm diameter capsules designed to absorb 14 kJ of x-rays have begun as an integrated test of drive temperature and symmetry, complementary to thin-shell symmetry diagnostic capsules. These capsule implosions are characterized by excellent control of symmetry (< 3% time-integrated), but low hohlraum efficiency (< 2%). Possible methods to increase the capsule absorbed energy in the DEH include mixed-component hohlraums, large diameter foam ablator capsules, transmissive shine shields between the z-pinch and capsule, higher spoke electrode x-ray transmission, a double-sided power feed, and smaller initial radius z-pinch wire arrays. Simulations will explore the potential for each of these modifications to increase the capsule coupling efficiency for near-term experiments on Z and ZR

  18. Design procedure of capsule with multistage heater control (named MUSTAC)

    International Nuclear Information System (INIS)

    A capsule with electric heaters at multistage (named MUSTAC) is a type of capsule used in JMTR. The heaters are assembled in the capsule. Supply electric current to the heaters can be independently adjusted with a control systems that keeps irradiation specimens to constant temperature. The capsule being used, the irradiation specimen are inserted into specimen holders. Gas-gap size, between outer surface of specimen holders and inner surface of capsule casing, is calculated and determined to be flatten temperature of loaded specimens over the region. The rise or drop of specimen temperature in accordance with reactor power fluctuations is corrected within the target temperature of specimen by using the heaters filled into groove at specimen holder surface. The present report attempts to propose a reasonable design procedure of the capsules by means of compiling experience for designs, works and irradiation data of the capsules and to prepare for useful informations against onward capsule design. The key point of the capsule lies on thermal design. Now design thermal calculations are complicated in case of specimen holder with multihole. Resolving these issues, it is considered from new on that an emphasis have to placed on settling a thermal calculation device, for an example, a computer program on calculation specimen temperature. (author)

  19. Design Improvements of the Protection Tube of a Fuel Capsule for the Development of a Capsule Assembly Process

    International Nuclear Information System (INIS)

    New capsule assembling technology and reinstrumentation technology has been developed to meet the demands for the high burnup test at HANARO since 2003. In 2003, a mockup of the capsule assembly machine was designed and fabricated. The performance test which started in 2004 was undertaken to determine and present the main performance characteristics of the capsule assembly machine (CAM) including the special tools. In 2005, the need to develop new techniques that can assembly the capsule's components such as a capsule's main body and a protection tube was recognized for the re-irradiation test techniques in the HANARO reactor. A series of analyses using a finite element analysis program, ANSYS and full scale tests were performed to improve the design of the capsule's components for an effective utilization of the CAM. This paper presents a summary of the latest results of the design improvements and the performance tests

  20. Postirradiation examination of capsule GF-4

    International Nuclear Information System (INIS)

    The GF-4 capsule test was irradiated in the SILOE reactor at Grenoble, France between April 8, 1975 and July 26, 1976. High-enriched uranium (HEU) UC2 and weak acid resin (WAR) UC/sub x/O/sub y/ fissile and ThO2 fertile particles were tested. Postirradiation examination of cured-in-place fuel rods showed no fuel rod/graphite element interaction. In addition, all rods exhibited adequate structural integrity. Irradiation-induced dimensional changes for rods containing all TRISO-coated fuel were consistent with model predictions; however, rods containing BISO-coated fuel exhibited greater volumetric contractions than predicted

  1. C5 capsule operation modes analysis

    International Nuclear Information System (INIS)

    This paper is part of the Nuclear Research Institute Program 13 dedicated to 'TRIGA Research Reactor performance enhancing' and its objective is improving the engineering of the structural materials irradiation. The paper raises the knowledge level on C5 capsule irradiation modes and utilizes previous results in order to increase C5 performances. In the paper the irradiation modes to test zirconium yttrium sample are assessed. These tests are proposed by AECL. There are presented the C5 initial conditions and models. Also. there are presented the thermal hydraulic conditions during normal and accidental operation. The results will be used in the C5 safety report. (authors)

  2. Chinese astronomy

    OpenAIRE

    Macfarlane, Alan; Cullen, Christopher

    2004-01-01

    Standing in the observatory in Beijing, Christopher Cullen discusses the nature and sophistication of Chinese astronomy in the medieval period. The political as well as the intellectual interest in astronomy is outlined.

  3. Chinese Confucianism

    OpenAIRE

    Macfarlane, Alan; Cullen, Christopher

    2004-01-01

    Confucianism has deeply influenced Chinese civilization. Christopher Cullen describes its effect on education, social structure and knowledge over the past centuries, against the backdrop of a Confucian building in Beijing.

  4. New reduced volume preparation regimen in colon capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    Yasuo Kakugawa; Kazuhide Higuchi; Shinji Tanaka; Hideki Ishikawa; Hisao Tajiri; Yutaka Saito; Shoichi Saito; Kenji Watanabe; Naoki Ohmiya; Mitsuyuki Murano; Shiro Oka; Tetsuo Arakawa; Hidemi Goto

    2012-01-01

    AIM:To evaluate the effectiveness of our proposed bowel preparation method for colon capsule endoscopy.METHODS:A pilot,multicenter,randomized controlled trial compared our proposed "reduced volume method" (group A) with the "conventional volume method" (group B) preparation regimens.Group A did not drink polyethylene glycol electrolyte lavage solution (PEGELS) the day before the capsule procedure,while group B drank 2 L.During the procedure day,groups A and B drank 2 L and 1 L of PEG-ELS,respectively,and swallowed the colon capsule (PillCam COLON(R) capsule).Two hours later the first booster of 100 g magnesium citrate mixed with 900 mL water was administered to both groups,and the second booster was administered six hours post capsule ingestion as long as the capsule had not been excreted by that time.Capsule videos were reviewed for grading of cleansing level.RESULTS:Sixty-four subjects were enrolled,with results from 60 analyzed.Groups A and B included 31 and 29 subjects,respectively.Twenty-nine (94%) subjects in group A and 25 (86%) subjects in group B had adequate bowel preparation (ns).Twenty-two (71%) of the 31 subjects in group A excreted the capsule within its battery life compared to 16 (55%) of the 29 subjects in group B (ns).Of the remaining 22 subjects whose capsules were not excreted within the battery life,all of the capsules reached the left side colon before they stopped functioning.A single adverse event was reported in one subject who had mild symptoms of nausea and vomiting one hour after starting to drink PEG-ELS,due to ingesting the PEG-ELS faster than recommended.CONCLUSION:Our proposed reduced volume bowel preparation method for colon capsule without PEG-ELS during the days before the procedure was as effective as the conventional volume method.

  5. Cluster ion beam polishing for inertial confinement fusion target capsules

    International Nuclear Information System (INIS)

    Targets for Inertial Confinement Fusion (ICF) typically consist of a hollow, spherical capsule filled with a mixture of hydrogen isotopes. Typically, these capsules are irradiated by short, intense pulses of either laser light (''direct drive'') or laser-generated. x-rays (''indirect drive''), causing them to implode This compresses and heats the fuel, leading to thermonuclear fusion. This process is highly sensitive to hydrodynamic (e.g., Rayleigh-Taylor) instabilities, which can be initiated by imperfections in the target. Thus, target capsules must be spherical and smooth One of the lead capsule designs for the National Ignition Facility, a 1.8 MJ laser being built at Livermore, calls for a 2-mm- diam capsule with a 150-microm-thick copper-doped beryllium wall. These capsules can be fabricated by sputter depositing the metal onto a spherical plastic mandrel. This results in surfaces with measured Rq's of 50 to 150 nm, as measured with an atomic force microscope For optimal performance the roughness should be below 10 nm rms We have begun studying the use of ion cluster beam polishing as a means of improving the surface finish of as-deposited capsules In this approach, a batch of capsules would be agitated in a bounce pan inside a vacuum chamber during exposure to the cluster beam. This would ensure a uniform beam dose around the capsule. We have performed preliminary experiments on both Be flats and on a stationary Be capsule On the capsule, the measured Rq went from 64 nm before polishing to 15 nm after This result was obtained without any effort at process optimization. Similar smoothing was observed on the planar samples

  6. Reinforcing effects of caffeine in coffee and capsules.

    Science.gov (United States)

    Griffiths, R R; Bigelow, G E; Liebson, I A

    1989-09-01

    In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee. PMID:2794839

  7. Potential value of Cs-137 capsules

    Energy Technology Data Exchange (ETDEWEB)

    Bloomster, C.H.; Brown, D.R.; Bruno, G.A.; Hazelton, R.F.; Hendrickson, P.L.; Lezberg, A.J.; Tingey, G.L.; Wilfert, G.L.

    1985-04-01

    We determined the value of Cs-137 compared to Co-60 as a source for the irradiation of fruit (apples and cherries), pork and medical supplies. Cs-137, in the WESF capsule form, had a value of approximately $0.40/Ci as a substitute for Co-60 priced at approximately $1.00/Ci. The comparison was based on the available curies emitted from the surface of each capsule. We developed preliminary designs for fourteen irradiation facilities; seven were based on Co-60 and seven were based on Cs-137. These designs provided the basis for estimating capital and operating costs which, in turn, provided the basis for determining the value of Cs-137 relative to Co-60 in these applications. We evaluated the effect of the size of the irradiation facility on the value of Cs-137. The cost of irradiation is low compared to the value of the product. Irradiation of apples for disinfestation costs $.01 to .02 per pound. Irradiation for trichina-safe pork costs $.02 per pound. Irradiation of medical supplies for sterilization costs $.07 to .12 per pound. The cost of the irradiation source, either Co-60 or Cs-137, contributed only a minor amount to the total cost of irradiation, about 5% for the fruit and hog cases and about 20% for the medical supply cases. We analyzed the sensitivity of the irradiation costs and Cs-137 value to several key assumptions.

  8. Potential value of Cs-137 capsules

    International Nuclear Information System (INIS)

    We determined the value of Cs-137 compared to Co-60 as a source for the irradiation of fruit (apples and cherries), pork and medical supplies. Cs-137, in the WESF capsule form, had a value of approximately $0.40/Ci as a substitute for Co-60 priced at approximately $1.00/Ci. The comparison was based on the available curies emitted from the surface of each capsule. We developed preliminary designs for fourteen irradiation facilities; seven were based on Co-60 and seven were based on Cs-137. These designs provided the basis for estimating capital and operating costs which, in turn, provided the basis for determining the value of Cs-137 relative to Co-60 in these applications. We evaluated the effect of the size of the irradiation facility on the value of Cs-137. The cost of irradiation is low compared to the value of the product. Irradiation of apples for disinfestation costs $.01 to .02 per pound. Irradiation for trichina-safe pork costs $.02 per pound. Irradiation of medical supplies for sterilization costs $.07 to .12 per pound. The cost of the irradiation source, either Co-60 or Cs-137, contributed only a minor amount to the total cost of irradiation, about 5% for the fruit and hog cases and about 20% for the medical supply cases. We analyzed the sensitivity of the irradiation costs and Cs-137 value to several key assumptions

  9. Quality evaluation of simvastatin compounded capsules

    Directory of Open Access Journals (Sweden)

    Flávia Dias Marques-Marinho

    2011-09-01

    Full Text Available Simvastatin is commercially available as tablets and compounded capsules in Brazil. Very few reports regarding these capsules' quality, and consequently their efficacy, are available. The pharmaceutical quality of 30 batches of 20 mg simvastatin capsules from the market was evaluated by weight determination, content uniformity, disintegration (Brazilian Pharmacopeia, assay and dissolution test (USP32 tablet monograph. A HPLC method was developed for assay, content uniformity and dissolution test, and specifications were also established. Out of the 30 batches evaluated, 29 showed capsule disintegration within 45 min and individual weight variation was within ±10% or ±7.5% relative to average weight, for 300 mg, respectively. Only 27 batches met dissolution test criteria with values >80% of the labeled amount in 45 min; 21 batches showed simvastatin content between 90.0-110.0% of the labeled amount and 19 batches had at least 9 out of 10 capsules with content uniformity values between 85.0-115.0% of the labeled amount with RSDNo Brasil, a sinvastatina está comercialmente disponível na forma de comprimidos e cápsulas manipuladas. Poucos relatos estão disponíveis sobre a qualidade e, consequentemente, a eficácia dessas cápsulas. A qualidade de 30 lotes de sinvastatina 20 mg cápsulas do mercado foi avaliada através da determinação de peso, uniformidade de conteúdo, desintegração (Farmacopéia Brasileira, doseamento e teste de dissolução (monografia comprimidos USP32. Método por CLAE foi desenvolvido para o doseamento, uniformidade de conteúdo e teste de dissolução; além disso, especificações foram estabelecidas. Dos 30 lotes avaliados, 29 apresentaram desintegração da cápsula até 45 min e a variação do peso individual foi ± 10% ou ± 7,5% em relação ao peso médio, se 300 mg, respectivamente. Apenas 27 lotes preencheram os critérios do teste de dissolução com valores > 80% da quantidade rotulada, em 45 min, 21

  10. Developing an Absorption–Based Quality Control Method for Hu–Gan–Kang–Yuan Capsules by UFLC–QTOF–MS/MS Screening and HPLC–DAD Quantitative Determination

    OpenAIRE

    Fenghuan Wei; Minting Chen; Chaohua Luo; Feilong Chen; Qun Shen; Zhixian Mo

    2016-01-01

    Traditional Chinese Medicine Preparations (TCMPs) contain massive numbers of ingredients responsible for their multiple efficacies. An absorption–based quality control method for complicated TCMPs using Hu–gan–kang–yuan Capsule (HGKYC) as an example was developed. To select proper chemical markers for quality control of HGKYC, an ultra–fast liquid chromatography (UFLC) coupled with electrospray ionization quadrupole time–off light mass spectrometry (UFLC–QTOF–MS/MS) method was used for the ra...

  11. Preparation and Quality Study of Artemether Capsules%蒿甲醚胶囊的制备及其含量研究

    Institute of Scientific and Technical Information of China (English)

    钟飞; 鲍光明; 党明殊

    2012-01-01

    建立蒿甲醚胶囊的制备及其质量的研究方法.通过辅料的选择、处方的设计与优化,摸索出了一套最佳处方的蒿甲醚胶囊的制备方法,并依照蒿甲醚的国家质量标准进行质量考察.筛选得出40 mg蒿甲醚,173.3 mg淀粉,26.7 mg糖粉,2.0 mg聚乙二醇(PEG)为最佳配方的蒿甲醚胶囊.所制得的胶囊质量稳定,符合质量标准且其工艺简单,适合工业化生产.%A method was established for the preparation and quality study of artemether capsules. Excipients and optirnzing formulas were selected and the best prescription for the preparation of artemether capsules were detected, and the quality of artemether capsules were inspected by national quality standards of artemether. The best prescription was 40 mg of artemether, 173.3 mg of starch, 26.7 mg of sugar and 2.0 mg of Polyethylene glycol. The prepared capsules possess stable quality and correspond with its Chinese Pharmacopoeia standard. The prescription and preparation of artemether capsules are simple and suitable for industrial production, and the product meet the quality standard.

  12. Streptococcus pneumoniae capsule determines disease severity in experimental pneumococcal meningitis.

    Science.gov (United States)

    Hathaway, Lucy J; Grandgirard, Denis; Valente, Luca G; Täuber, Martin G; Leib, Stephen L

    2016-03-01

    Streptococcus pneumoniaebacteria can be characterized into over 90 serotypes according to the composition of their polysaccharide capsules. Some serotypes are common in nasopharyngeal carriage whereas others are associated with invasive disease, but when carriage serotypes do invade disease is often particularly severe. It is unknown whether disease severity is due directly to the capsule type or to other virulence factors. Here, we used a clinical pneumococcal isolate and its capsule-switch mutants to determine the effect of capsule, in isolation from the genetic background, on severity of meningitis in an infant rat model. We found that possession of a capsule was essential for causing meningitis. Serotype 6B caused significantly more mortality than 7F and this correlated with increased capsule thickness in the cerebrospinal fluid (CSF), a stronger inflammatory cytokine response in the CSF and ultimately more cortical brain damage. We conclude that capsule type has a direct effect on meningitis severity. This is an important consideration in the current era of vaccination targeting a subset of capsule types that causes serotype replacement. PMID:27009189

  13. Organization of the interior of molecular capsules by hydrogen bonding.

    Science.gov (United States)

    Atwood, Jerry L; Barbour, Leonard J; Jerga, Agoston

    2002-04-16

    The enclosure of functional entities within a protective boundary is an essential feature of biological systems. On a molecular scale, free-standing capsules with an internal volume sufficiently large to house molecular species have been synthesized and studied for more than a decade. These capsules have been prepared by either covalent synthesis or self-assembly, and the internal volumes have ranged from 200 to 1,500 A(3). Although biological systems possess a remarkable degree of order within the protective boundaries, to date only steric constraints have been used to order the guests within molecular capsules. In this article we describe the synthesis and characterization of hexameric molecular capsules held together by hydrogen bonding. These capsules possess internal order of the guests brought about by hydrogen bond donors within, but not used by, the framework of the capsule. The basic building blocks of the hexameric capsules are tetrameric macrocycles related to resorcin[4]arenes and pyrogallol[4]arenes. The former contain four 1,3-dihydroxybenzene rings bridged together by -CHR- units, whereas the latter contain four 1,2,3-trihydroxybenzene rings bridged together. We now report the synthesis of related mixed macrocycles, and the main focus is on the macrocycle composed of three 1,2,3-trihydroxybenzene rings and one 1,3-dihydroxybenzene ring bridged together. The mixed macrocycles self-assemble from a mixture of closely related compounds to form the hexameric capsule with internally ordered guests. PMID:11943875

  14. 1964 computer run on a laser-imploded capsule

    International Nuclear Information System (INIS)

    WAZER Alchemy 7b (WA-7b) is a WAZER calculation of a laser-driven micro-implosion of a spherical capsule consisting of a thin gold pusher surrounded by a thick (frozen) deuterium ablator. The properties of the target capsule and the shape of the laser pulse used to irradiate it are described

  15. Highly active antibody-modified magnetic polyelectrolyte capsules.

    Science.gov (United States)

    Valdepérez, Daniel; Del Pino, Pablo; Sánchez, Lourdes; Parak, Wolfgang J; Pelaz, Beatriz

    2016-07-15

    Polyelectrolyte hollow capsules are versatile platforms typically used for encapsulation of a wide variety of macromolecules in their cavity. The polymer shell of these capsules as composed by alternating layers of oppositely charged polyelectrolytes also allows for adding additional functionalities. The properties of the shell can be for example engineered by trapping different nanoparticles in-between the shell layers and/or by attaching bioactive molecules such as antibodies to the outermost layer. Herein, iron oxide NPs were inmobilized into the shell of polyelectrolyte capsules and the outermost layer of the shell was covalently modified with anti peroxidase antibodies. These capsules act as prototype model system, aiming to obtain a microstructure with the potential capability to specifically recognize and separate macromolecules. Due to the magnetic nanoparticles in the capsule shell, the capsules together with the attached target might be extracted by magnetic field gradients. Here we verified this approach by extracting horseradish peroxidase from a solution through magnetic separation with capsules bearing antibodies against horseradish peroxidase. The bioactivity of the capsules and the high degree of specific antibody functionalization were confirmed and quantified through an enzymatic reaction mediated by the extracted horseradish peroxidase. PMID:27089014

  16. Ignition scaling laws and their application to capsule design

    International Nuclear Information System (INIS)

    This paper investigates the amount of energy required to ensure the ignition of an inertial confinement fusion capsule. First, a series of one-dimensional LASNEX [G. B. Zimmerman and W. L. Kruer, Plasma Phys. Controlled Fusion 2, 51 (1975)] simulations are performed to create a database of barely ignited capsules that span the parameter regime of interest. This database is used to develop scaling laws for the ignition energy in terms of both the stagnated capsule parameters and the in-flight capsule parameters, and to explore the connection between these two parameter sets. We then examine how much extra energy is required to overcome the effect of the inevitable surface imperfections that are amplified during the implosion process. These perturbations can lead to break up of the capsule in flight or to mix of cold fuel into the hot spot, both of which can cause the capsule to fail. As an example, a family of capsules with fixed adiabat, drive pressure, and absorbed energy is studied; the capsule from this family that is maximally robust to these failure modes is found

  17. Ignition Scaling Laws and Their Application to Capsule Design

    International Nuclear Information System (INIS)

    In this paper a two pronged approach is taken to investigating the energy required for ignition of inertial confinement fusion capsules. A series of one dimensional LASNEX simulations is performed to create a database of barely ignited capsules that span the parameter regime Of interest. This database is used to develop scaling laws for the ignition energy in terms of both the stagnated capsule parameters and the inflight capsule parameters, and explore the connection between these two parameter sets. The second part of this paper examines how much extra energy is required to overcome the effect of the inevitable surface imperfections that are amplified during the implosion process and can lead to capsule break up in flight or to mix of cold fuel into the hotspot, both of which can cause the capsule to fail to ignite. By means of an example, the optimization of a capsule with fixed adiibat, drive pressure, and absorbed energy is performed; the capsule that is maximally robust to these failure modes is found

  18. Design of capsules capable of argon-filling

    International Nuclear Information System (INIS)

    The possibility of the use of polycarbosilane capsules as fuel container in inertial confinement fusion experiments was analyzed in the paper. Primary study indicates that the polycarbosilane capsules can be filled with argon by means of diffusion and possess reasonable retention time for deuterium. (author)

  19. Ignition Scaling Laws and Their Application to Capsule Design

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, M.C.; Tabak, M.; Lindl, J.D.

    2000-10-20

    In this paper a two pronged approach is taken to investigating the energy required for ignition of inertial confinement fusion capsules. A series of one dimensional LASNEX simulations is performed to create a database of barely ignited capsules that span the parameter regime Of interest. This database is used to develop scaling laws for the ignition energy in terms of both the stagnated capsule parameters and the inflight capsule parameters, and explore the connection between these two parameter sets. The second part of this paper examines how much extra energy is required to overcome the effect of the inevitable surface imperfections that are amplified during the implosion process and can lead to capsule break up in flight or to mix of cold fuel into the hotspot, both of which can cause the capsule to fail to ignite. By means of an example, the optimization of a capsule with fixed adiibat, drive pressure, and absorbed energy is performed; the capsule that is maximally robust to these failure modes is found.

  20. Serum Ceramide Kinase as a Biomarker of Cognitive Functions, and the Effect of Using Two Slimming Dietary Therapies in Obese Middle Aged Females

    OpenAIRE

    Maha I.A. Moaty; Suzanne Fouad; Salwa M. El Shebini; Yusr M. I. Kazem; Nihad H. Ahmed; Magda S. Mohamed; Hussein, Ahmed M. S.; Atiat M. Arafa; Laila M. Hanna; Salwa T. Tapozada

    2015-01-01

    AIM: Highlighting the impact of obesity on mental and cognitive functions using serum ceramide kinase enzyme concentration as a biomarker for cognitive evaluation in the middle aged females, and also targeting to control the obesity and simultaneously postponing the deterioration of the cognitive functions, by implementing two slimming dietary therapies each incorporating different functional ingredients known to boost cognition. SUBJECTS AND METHODS: Ninety six obese middle aged females, ...

  1. Analysing intracellular deformation of polymer capsules using structured illumination microscopy

    Science.gov (United States)

    Chen, Xi; Cui, Jiwei; Sun, Huanli; Müllner, Markus; Yan, Yan; Noi, Ka Fung; Ping, Yuan; Caruso, Frank

    2016-06-01

    Understanding the behaviour of therapeutic carriers is important in elucidating their mechanism of action and how they are processed inside cells. Herein we examine the intracellular deformation of layer-by-layer assembled polymer capsules using super-resolution structured illumination microscopy (SIM). Spherical- and cylindrical-shaped capsules were studied in three different cell lines, namely HeLa (human epithelial cell line), RAW264.7 (mouse macrophage cell line) and differentiated THP-1 (human monocyte-derived macrophage cell line). We observed that the deformation of capsules was dependent on cell line, but independent of capsule shape. This suggests that the mechanical forces, which induce capsule deformation during cell uptake, vary between cell lines, indicating that the capsules are exposed to higher mechanical forces in HeLa cells, followed by RAW264.7 and then differentiated THP-1 cells. Our study demonstrates the use of super-resolution SIM in analysing intracellular capsule deformation, offering important insights into the cellular processing of drug carriers in cells and providing fundamental knowledge of intracellular mechanobiology. Furthermore, this study may aid in the design of novel drug carriers that are sensitive to deformation for enhanced drug release properties.Understanding the behaviour of therapeutic carriers is important in elucidating their mechanism of action and how they are processed inside cells. Herein we examine the intracellular deformation of layer-by-layer assembled polymer capsules using super-resolution structured illumination microscopy (SIM). Spherical- and cylindrical-shaped capsules were studied in three different cell lines, namely HeLa (human epithelial cell line), RAW264.7 (mouse macrophage cell line) and differentiated THP-1 (human monocyte-derived macrophage cell line). We observed that the deformation of capsules was dependent on cell line, but independent of capsule shape. This suggests that the mechanical forces

  2. Analysis of Fission Products on the AGR-1 Capsule Components

    Energy Technology Data Exchange (ETDEWEB)

    Paul A. Demkowicz; Jason M. Harp; Philip L. Winston; Scott A. Ploger

    2013-03-01

    The components of the AGR-1 irradiation capsules were analyzed to determine the retained inventory of fission products in order to determine the extent of in-pile fission product release from the fuel compacts. This includes analysis of (i) the metal capsule components, (ii) the graphite fuel holders, (iii) the graphite spacers, and (iv) the gas exit lines. The fission products most prevalent in the components were Ag-110m, Cs 134, Cs 137, Eu-154, and Sr 90, and the most common location was the metal capsule components and the graphite fuel holders. Gamma scanning of the graphite fuel holders was also performed to determine spatial distribution of Ag-110m and radiocesium. Silver was released from the fuel components in significant fractions. The total Ag-110m inventory found in the capsules ranged from 1.2×10 2 (Capsule 3) to 3.8×10 1 (Capsule 6). Ag-110m was not distributed evenly in the graphite fuel holders, but tended to concentrate at the axial ends of the graphite holders in Capsules 1 and 6 (located at the top and bottom of the test train) and near the axial center in Capsules 2, 3, and 5 (in the center of the test train). The Ag-110m further tended to be concentrated around fuel stacks 1 and 3, the two stacks facing the ATR reactor core and location of higher burnup, neutron fluence, and temperatures compared with Stack 2. Detailed correlation of silver release with fuel type and irradiation temperatures is problematic at the capsule level due to the large range of temperatures experienced by individual fuel compacts in each capsule. A comprehensive Ag 110m mass balance for the capsules was performed using measured inventories of individual compacts and the inventory on the capsule components. For most capsules, the mass balance was within 11% of the predicted inventory. The Ag-110m release from individual compacts often exhibited a very large range within a particular capsule.

  3. Adsorption and desorption of phosphorus in ceramic capsules

    International Nuclear Information System (INIS)

    Experiments were carried out in order to analyse the capacity of adsorving P from water using ceramic capsules with 32P, in the presence and absence of water flow through the capsule. Also studied was the desorption of 32P from the capsule in water, with and without water flow. The desorption of residual 32P was analysed by isotopic exchange with 31P, also with and without water flow. It was observed that, in the presence of a flow, the capsule retained 32P from the solution, which was weakly desorbed by water but was isotopically exchanged with 31P. In the absence of a flow, the capsule was not an efficient P adsorber. (Author)

  4. [Capsule endoscopy--the past, presence, and future].

    Science.gov (United States)

    Drastich, P

    2006-01-01

    Wireless capsule endoscopy is a safe non-invasive method for the examination of the small intestine and terminal oesophagus. Examination is well tolerated by most of the patients. Due to the possibility to assess mucosa of the small intestine in details, capsule endoscopy has the diagnostical yield higher than other available methods. It is effective namely for study of obscure bleeding, celiac disease and Crohn's disease. Capsule endoscopy is aimed at the longterm follow up of patients with Barrett's oesophagus, however, the costs are higher than using gastroscopy. Capsule retention represents the most serious and practically the only complication of the examination which frequently requires surgical treatment. The future of capsule endoscopy depends on the next development of the technology. PMID:16835993

  5. Effect of inclination of freezing in a sealed cylindrical capsule

    International Nuclear Information System (INIS)

    Experiments were performed to study the heat transfer processes that occur during freezing inside of a sealed cylindrical capsule when the inclination of the capsule is varied parametrically from vertical to horizontal. The phase-change medium was 99 percent pure n-eicosane paraffin. It was found that the amount of mass that solidified during a given freezing period was insensitive to the inclination of the capsule, as was the amount of energy extracted from the capsule. Only highly localized quantities such as the local frozen layer thickness reflected the inclination of the cylinder. Parametric variations were also performed for the degree of subcooling of the capsule wall below the fusion temperature and for the degree of superheating of the liquid phase at the onset of freezing. These variations facilitated the identification of the relative importance of the latent and sensible energies to the total extracted energy

  6. Synthesis and evaluation of dummy molecularly imprinted microspheres for the specific solid-phase extraction of six anthraquinones from slimming tea.

    Science.gov (United States)

    Wu, Xingqiang; Liang, Shuxuan; Ge, Xusheng; Lv, Yunkai; Sun, Hanwen

    2015-05-01

    Dummy molecularly imprinted microspheres with danthron as template were synthesized and their performance was evaluated. Accelerated solvent extraction can rapidly and effectively remove template molecules from the microspheres. The microspheres were applied as a specific sorbent for solid-phase extraction of six anthraquinones from slimming tea, showing excellent affinity and high selectivity to danthron and the target analytes. The molecular recognition mechanisms were discussed by the experimental validation with IR spectroscopy. The sample was treated using accelerated solvent extraction followed by dummy molecularly imprinted microspheres solid-phase extraction. Under the optimized ultra high performance liquid chromatographic conditions, the six target analytes can be baseline separated in 8 min, and good linearity was obtained in a range of 0.1-40 μg/mL with the correlation coefficient (r(2)) of ≥0.9998. The method limit of quantification was in a range of 1-2 mg/kg, it can ensure analysis of anthraquinones at mg/kg level. The intra- and interday precision (RSD, n = 6) for the analysis of the six analytes in a slimming tea was less than 4.5 and 5.4%, respectively. The developed method can be applied for the selective extraction, effective separation, and rapid determination of six anthraquinones in slimming tea. PMID:25677958

  7. Fufang Xue Shuan Tong capsules inhibit renal oxidative stress markers and indices of nephropathy in diabetic rats

    OpenAIRE

    Fang, Donghong; WAN, XUESI; Deng, Wanping; Guan, Hongyu; KE, WEIJIAN; Xiao, Haipeng; Li, Yanbing

    2012-01-01

    Fufang Xue Shuan Tong (FXST) capsules, a traditional Chinese medicine, have been used to treat diabetic nephropathy for many years. FXST has been shown to attenuate elevated levels of oxidative stress in the retina of diabetic rats. However, whether FXST protects kidneys through the same mechanism(s) remains unclear. In this study, diabetes was induced in rats by administration of a high-fat diet and low-dose streptozotocin. Rats were administered low (450 mg/kg/day), middle (900 mg/kg/day) o...

  8. High-speed precision weighing of pharmaceutical capsules

    International Nuclear Information System (INIS)

    In this paper, we present a cost-effective method for fast and accurate in-line weighing of hard gelatin capsules based on the optimized capacitance sensor and real-time processing of the capsule capacitance profile resulting from 5000 capacitance measurements per second. First, the effect of the shape and size of the capacitive sensor on the sensitivity and stability of the measurements was investigated in order to optimize the performance of the system. The method was tested on two types of hard gelatin capsules weighing from 50 mg to 650 mg. The results showed that the capacitance profile was exceptionally well correlated with the capsule weight with the correlation coefficient exceeding 0.999. The mean precision of the measurements was in the range from 1 mg to 3 mg, depending on the size of the capsule and was significantly lower than the 5% weight tolerances usually used by the pharmaceutical industry. Therefore, the method was found feasible for weighing pharmaceutical hard gelatin capsules as long as certain conditions are met regarding the capsule fill properties and environment stability. The proposed measurement system can be calibrated by using only two or three sets of capsules with known weight. However, for most applications it is sufficient to use only empty and nominally filled capsules for calibration. Finally, a practical application of the proposed method showed that a single system is capable of weighing around 75 000 capsules per hour, while using multiple systems could easily increase the inspection rate to meet almost any requirements

  9. Low Power Transmitter for Wireless Capsule Endoscope

    International Nuclear Information System (INIS)

    This paper presents the transmitter circuit designed for the application of wireless capsule endoscope to overcome the limitation of conventional endoscope. The design is performed using CMOS 0.13 μm technology. The transmitter is designed to operate at centre frequency of 433.92 MHz, which is one of the ISM band. Active mixer and ring oscillator made up the transmitter and it consumes 1.57 mA of current using a supply voltage of 1.2 V, brings the dc power consumption of the transmitter to be 1.88 mW. Data rate of 3.5 Mbps ensure it can transmit high quality medical imaging.

  10. Vortex Rings from Sphagnum Moss Capsules

    CERN Document Server

    Chang, Emily S; Cha, Jung Ha; Strassman, Sam; Hard, Clara; Whitaker, Dwight L

    2010-01-01

    Long distance wind dispersal requires small spores with low terminal velocities, which can be held aloft by turbulent air currents until they are deposited in suitable habitats for colonization. The inherent difficulty in dispersing spores by wind is that spores easily carried by wind are also rapidly decelerated when moving through still air. Thus the height of spore release is critical in determining their range of dispersal. Vascular plants with wind dispersed spores use the height of the plant to lift spores into sufficient wind currents for dispersal, however non-vascular plants such as Sphagnum cannot grow sufficiently tall. These fluid dynamics videos show how exploding capsules of {\\em Sphagnum} moss generate vortex rings to carry spores to heights above 10 cm with an initial velocity of 16 m s$^{-1}$. In contrast spores launched ballistically at these speeds through still air would travel only 2-7 mm.

  11. Capsule HRB-15B postirradiation examination report

    International Nuclear Information System (INIS)

    Capsule HRB-15B design tested 184 thin graphite trays containing unbonded fuel particles to peak exposures of 6.6 x 1025 n/m2 (E > 29 fJ)/sub HTGR/ fast fluence, approx. 27% fissions per initial metal atom (FIMA) fissile burnup, and 6% FIMA fertile burnup at nominal time-averaged temperatures of 815 to 9150C. The capsule tested a variety of low-enriched uranium (approx. 19.5% U-235) fissile particle types, including UC2, UC/sub x/O/sub y/, UO2, zirconium-buffered UO2 (referred to in this report as UO2/sup *), and 1:1(Th,U)O2 with both TRISO and silicon-BISO coatings. All fertile particles were ThO2 with BISO, silicon-BISO, or TRISO coatings. The findings indicated that all TRISO particles retained virtually all of their fission product inventories, except small quantities of silver, at these irradiation temperatures, while some of the silicon-BISO particles released significant amounts of both silver and cesium. No kernel migration, pressure vessel, or outer pyrolytic carbon (OPyC) failures were observed in the fuel particles, which had total diameters of 2/sup */ particles exhibited no detrimental irradiation effects, but they contained pure carbon precipitates in the kernels after irradiation which were not observed in the undoped UO2 particles. Postirradiation examination revealed no differences in the irradiation performance of three UC/sub x/O/sub y/ kernel types with varying oxygen/uranium ratios

  12. A comparative study on liquid core formulation on the diameter on the alginate capsules

    Science.gov (United States)

    Ong, Hui-Yen; Lee, Boon-Beng; Radzi, AkmalHadi Ma'; Zakaria, Zarina; Chan, Eng-Seng

    2015-08-01

    Liquid core capsule has vast application in biotechnology related industries such as pharmaceutical, medical, agriculture and food. Formulation of different types of capsule was important to determine the performance of the capsule. Generally, the liquid core capsule with different formulations generated different size of capsule.Therefore, the aim of this project is to investigate the effect of different liquid core solution formulations on the diameter of capsule. The capsule produced by extruding liquid core solutions into sodium alginate solution. Three types of liquid core solutions (chitosan, xanthan gum, polyethylene glycol (PEG)) were investigated. The results showed that there is significant change in capsule diameter despite in different types of liquid core solution were used and a series of capsule range in diameter of 3.1 mm to 4.5 mm were produced. Alginate capsule with chitosan formulation appeared to be the largest capsule among all.

  13. Adhesion and detachment of a capsule in axisymmetric flow

    Science.gov (United States)

    Keh, M. P.; Leal, L. G.

    2016-05-01

    The adhesion and detachment of a capsule on a solid boundary surface is studied via a combination of scaling theory and numerical simulation and the behavior is compared and contrasted with a vesicle. It is shown that the dominant physical property for both capsules and vesicles is the area dilation modulus Ks of the membrane. The nonzero shear modulus Gs for capsules increases the resistance to deformation and thus decreases slightly the equilibrium contact radius for an adhered capsule compared to an adhered vesicle. The detachment process in this study is due to an external axisymmetric flow. Unlike a rigid body that must be pulled away without change of shape, capsules (and vesicles) almost always detach dominantly by peeling in which the contact radius decreases but the minimum separation distance does not change until the final moments of detachment. Compared to a vesicle with the same Ks, a capsule maintains a more compact shape and is harder to elongate under a given external flow. Hence, the detachment process is slower for capsules compared to vesicles with the same Ks.

  14. Design of new irradiation capsules for controlling temperature and fluence

    Energy Technology Data Exchange (ETDEWEB)

    Choo, K. N.; Choi, M. H.; Cho, M. S.; Shin, Y. T.; Kim, B. G. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2004-07-01

    Various irradiation devices have been developed at HANARO (High flux Advanced Neutron Application ReactOr). Among the irradiation facilities, a capsule is the most useful device to cope with various test requirements. Instrumented and non-instrumented capsules have been developed at HANARO for new alloy and fuel developments and the life time estimation of nuclear power plants. Extensive efforts have been made to establish design and manufacturing technology for the capsule and temperature control system, which should be compatible with HANARO's characteristics. 9 instrumented and 2 non-instrumented capsules were designed, fabricated and successfully irradiated since the first non-instrumented capsule (96M-01K) for various materials irradiation. In an irradiation test using a research reactor, temperature and fluence are mainly dependent of reactor operation condition such as reactor power mode and operation time. In consequence, the irradiated specimen is subjected to the change of temperature as well as of neutron flux during reactor power transient such as start-up and shut-down. A large difference in the defect structure has been reported to be caused by this transient irradiation from the mechanism of the defect structure development. Therefore, the development of new capsule technology has been required to overcome those limitations. In this paper, current status of development of the capsule for controlling temperature and fluence in HANARO is described.

  15. Design of new irradiation capsules for controlling temperature and fluence

    International Nuclear Information System (INIS)

    Various irradiation devices have been developed at HANARO (High flux Advanced Neutron Application ReactOr). Among the irradiation facilities, a capsule is the most useful device to cope with various test requirements. Instrumented and non-instrumented capsules have been developed at HANARO for new alloy and fuel developments and the life time estimation of nuclear power plants. Extensive efforts have been made to establish design and manufacturing technology for the capsule and temperature control system, which should be compatible with HANARO's characteristics. 9 instrumented and 2 non-instrumented capsules were designed, fabricated and successfully irradiated since the first non-instrumented capsule (96M-01K) for various materials irradiation. In an irradiation test using a research reactor, temperature and fluence are mainly dependent of reactor operation condition such as reactor power mode and operation time. In consequence, the irradiated specimen is subjected to the change of temperature as well as of neutron flux during reactor power transient such as start-up and shut-down. A large difference in the defect structure has been reported to be caused by this transient irradiation from the mechanism of the defect structure development. Therefore, the development of new capsule technology has been required to overcome those limitations. In this paper, current status of development of the capsule for controlling temperature and fluence in HANARO is described

  16. A wireless narrowband imaging chip for capsule endoscope.

    Science.gov (United States)

    Lan-Rong Dung; Yin-Yi Wu

    2010-12-01

    This paper presents a dual-mode capsule gastrointestinal endoscope device. An endoscope combined with a narrowband image (NBI), has been shown to be a superior diagnostic tool for early stage tissue neoplasms detection. Nevertheless, a wireless capsule endoscope with the narrowband imaging technology has not been presented in the market up to now. The narrowband image acquisition and power dissipation reduction are the main challenges of NBI capsule endoscope. In this paper, we present the first narrowband imaging capsule endoscope that can assist clinical doctors to effectively diagnose early gastrointestinal cancers, profited from our dedicated dual-mode complementary metal-oxide semiconductor (CMOS) sensor. The dedicated dual-mode CMOS sensor can offer white-light and narrowband images. Implementation results show that the proposed 512 × 512 CMOS sensor consumes only 2 mA at a 3-V power supply. The average current of the NBI capsule with an 8-Mb/s RF transmitter is nearly 7 ~ 8 mA that can continuously work for 6 ~ 8 h with two 1.5-V 80-mAh button batteries while the frame rate is 2 fps. Experimental results on backside mucosa of a human tongue and pig's small intestine showed that the wireless NBI capsule endoscope can significantly improve the image quality, compared with a commercial-of-the-shelf capsule endoscope for gastrointestinal tract diagnosis. PMID:23853384

  17. Chinese Dream

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    The general managers of South Korean auto giants Hyundai and Kia have high hopes for the growing Chinese auto market. Both companies went through a painstaking period as the financial crisis first roared across the globe. Jin Shan-fa, General Manager of Hyundai Motor Group

  18. SATCAP-C : a program for thermal hydraulic design of pressurized water injection type capsule

    International Nuclear Information System (INIS)

    There are capsules called 'Pressure Water Injection Type Capsule' as a kind of irradiation devices at the Japan Materials Testing Reactor (JMTR). A type of the capsules is a 'Boiling Water Capsule' (usually named BOCA). The other type is a 'Saturated Temperature Capsule' (named SATCAP). When the water is kept at a constant pressure, the water temperature does not become higher than the saturated temperature so far as the water does not fully change to steam. These type capsules are designed on the basis of the conception of applying the water characteristic to the control of irradiation temperature of specimens in the capsules. In designing of the capsules in which the pressurized water is injected, thermal performances have to be understood as exactly as possible. It is not easy however to predict thermal performances such as axially temperature distribution of water injected in the capsule, because there are heat-sinks at both side of inner and outer of capsule casing as the result that the water is fluid. Then, a program (named SATCAP-C) for the BOCA and SATCAP was compiled to grasp the thermal performances in the capsules and has been used the design of the capsules and analysis of the data obtained from some actual irradiation capsules. It was confirmed that the program was effective in thermal analysis for the capsules. The analysis found out the values for heat transfer coefficients at various surfaces of capsule components and some thermal characteristics of capsules. (author)

  19. A Clinical Study of Yigu Capsule(益骨胶囊)in Treating Postmenopausal Osteoporosis

    Institute of Scientific and Technical Information of China (English)

    ZHANG Rong-hua; CHEN Ke-ji; LU Da-xiang; ZHU Xiao-feng; MA Xiao-chang

    2005-01-01

    Objective: To observe the efficacy and safety of Yigu capsule (兴骨胶囊, YGC), a Chinese herbal compound preparation, in treating postmenopausal osteoporosis (PMO) and to explore its possible mechanism. Methods: The clinical study was conducted in a prospective, randomized, double blinded method lasting for 6 months with placebo and positive control. Two hundred and ten PMO patients with confirmed diagnosis were assigned into the YGC group, the calciferol group and the placebo group. Besides being administered element calcium, they were treated with YGC, calciferol capsule and placebo capsule respectively. And such symptoms as newly found fracture and ostealgia, bone mineral density (BMD) of the 2nd-4th lumbar vertebrae (L2-4) and upper femur, blood and urinary indexes for bone metabolism, sex hormone level and adverse reaction that occurred in patients were observed. Results: In the YGC group, the total effective rate was 95.50%, with no new occurrence of fractures, which was significantly better than that in the other two groups ( P<0.05). Moreover, in the YGC group, the increase rate of BMD was 9.83 % in L2-4, 4.09 %in femoral neck, 4.60% in Wards triangle, 3.00% in greater trochanter, which was also better than that in the placebo group ( P<0.05, P<0.01). As compared with the placebo group, levels in the YGC group of urinary oxyproline hydroxyproline/creatinine, urinary calcium/creatinine were significantly lower, serum and bone alkaline phosphatase, osteocalcin, estradiol and estradiol/testosterone were significantly higher, but no difference was shown in the comparison of testosterone level. In the observation period, no abnormality in blood or urine routine, liver or renal function was found. Only mild, transient gastro-intestinal response occurred in individual patients, but it did not affect the treatment. Conclusion: YGC could treat PMO effectively, as it could obviously increase the BMD of lumbar vertebrae and coxafemoral bone, elevate the

  20. Wireless capsule video endoscopy:Three years of experience

    Institute of Scientific and Technical Information of China (English)

    Rami Eliakim

    2004-01-01

    AIM: To review and summerize the current literatue regarding M2A wireless capsule endoscopy.METHODS: Peer reviewed publications regarding the use of capsule endoscopy as well as our personal experience were reviewed.RESULTS: Review of the literature dearly showed that capsule endoscopy was superior to enteroscopy, small bowel follow through and computerized tomography in patients with obscure gastrointestinal bleeding, iron deficiency anemia,or suspected Crohn′s disease. It was very sensitive for the diagnosis of small bowel tumors and for survailance of small bowel pathology in patients with Gardner syndrome or familial adenomatous polyposis syndrome. Its role in celiac disease and in patients with known Crohn′s disease was currently being investigated.CONCLUSION: Capsule video endoscopy is a superior and more sensitive diagnostic tool than barium follow through,enteroscopy and entero- CT in establishing the diagnosis of many small bowel pathologies.

  1. X-ray microscopic imaging of inertial fusion capsules

    International Nuclear Information System (INIS)

    Inertial fusion chamber is conducted in a metal chamber with polymer capsules. And the capsules are usually made of carbon, hydrogen and other low Z materials. It is difficult for traditional X-ray imaging technique to detect the inertial fusion capsules. X-ray phase contrast imaging has been used in low Z material imaging. However it has not been applied to low Z materials wrapped by strong absorption materials. In this paper, we construct a model and discuss the effect of parameters such as X-ray energy, distance of object to detector, and thickness of strong absorbing materials, on phase contrast imaging quality by simulation and experiment. We found it feasible to perform high resolution and nondestructive detection of inertial fusion capsules in a chamber by X-ray phase contrast imaging. And this technique may have other applications, such as inclusion detection in petroleum exploration. (authors)

  2. Capsule endoscopy of the future: What's on the horizon?

    Science.gov (United States)

    Slawinski, Piotr R; Obstein, Keith L; Valdastri, Pietro

    2015-10-01

    Capsule endoscopes have evolved from passively moving diagnostic devices to actively moving systems with potential therapeutic capability. In this review, we will discuss the state of the art, define the current shortcomings of capsule endoscopy, and address research areas that aim to overcome said shortcomings. Developments in capsule mobility schemes are emphasized in this text, with magnetic actuation being the most promising endeavor. Research groups are working to integrate sensor data and fuse it with robotic control to outperform today's standard invasive procedures, but in a less intrusive manner. With recent advances in areas such as mobility, drug delivery, and therapeutics, we foresee a translation of interventional capsule technology from the bench-top to the clinical setting within the next 10 years. PMID:26457013

  3. Nanoparticle-Stabilized Capsules for the Treatment of Bacterial Biofilms.

    Science.gov (United States)

    Duncan, Bradley; Li, Xiaoning; Landis, Ryan F; Kim, Sung Tae; Gupta, Akash; Wang, Li-Sheng; Ramanathan, Rajesh; Tang, Rui; Boerth, Jeffrey A; Rotello, Vincent M

    2015-08-25

    Bacterial biofilms are widely associated with persistent infections. High resistance to conventional antibiotics and prevalent virulence makes eliminating these bacterial communities challenging therapeutic targets. We describe here the fabrication of a nanoparticle-stabilized capsule with a multicomponent core for the treatment of biofilms. The peppermint oil and cinnamaldehyde combination that comprises the core of the capsules act as potent antimicrobial agents. An in situ reaction at the oil/water interface between the nanoparticles and cinnamaldehyde structurally augments the capsules to efficiently deliver the essential oil payloads, effectively eradicating biofilms of clinically isolated pathogenic bacteria strains. In contrast to their antimicrobial action, the capsules selectively promoted fibroblast proliferation in a mixed bacteria/mammalian cell system making them promising for wound healing applications. PMID:26083534

  4. The innervation of canine hip joint capsule: an anatomic study.

    Science.gov (United States)

    Huang, C H; Hou, S M; Yeh, L S

    2013-12-01

    To clarify the contributions of the nerves supplying the canine hip joint capsule for clinical application, cadaver study of six healthy mongrel dogs was performed. The pelvises and hindlimbs of cadavers were dissected and fixed in formaldehyde. Innervation of the joint capsule was investigated with the aid of an operative microscope. As a result, the canine hip joint capsule receives multiple innervations from articular branches of four nerves. They are articular nerve fibres of femoral, obturator, cranial gluteal and sciatic nerves from the cranioventral, caudoventral, craniolateral and dorsolateral directions of the joint, respectively. No branch originating from the caudal gluteal nerve was observed innervating the hip joint capsule. Our data provides useful information for research on the canine hip joint, including pain analysis with hip disorders and surgical nerve blockade to relieve pain. PMID:23410229

  5. Perforation forces of the intact porcine anterior lens capsule.

    Science.gov (United States)

    Ullrich, Franziska; Lussi, Jonas; Felekis, Dimitrios; Michels, Stephan; Petruska, Andrew J; Nelson, Bradley J

    2016-09-01

    During the first step of cataract surgery, the lens capsule is perforated and a circular hole is created with a sharp instrument, a procedure called capsulorhexis. To develop automated systems that can assist ophthalmologists during capsulorhexis, the forces required must be quantified. This study investigates perforation forces of the central anterior lens capsule in porcine eyes, which are used as a conservative model for the human eye. A micro-mechanical characterisation method is presented that measures capsular bag perforation forces with a high precision positioning and high-resolution force sensing system. The force during perforation of the anterior lens capsule was measured with various sized needles and indentation speeds and is found to be 15-35mN. A bio-mechanical model is identified that describes an exponential correlation between indentation force and depth, indicating strain hardening behaviour of the porcine anterior lens capsule. PMID:27254279

  6. [Clinical practice using colon capsule endoscopy].

    Science.gov (United States)

    Kakugawa, Yasuo; Matsumoto, Minori; Saito, Yutaka

    2014-01-01

    PillCam COLON capsule endoscopy(CCE) (Given Imaging Ltd., Yoqneam, Israel) is one of the most recent diagnostic technologies designed to explore the colorectum. The first generation of CCE was released onto the market in 2006, and the second generation (PillCam COLON 2 : CCE-2), with increased sensitivity, was released in 2009. The CCE-2 has 2 imagers with a much wider angle of view that has been increased to 172 degrees per imager, allowing nearly 360 degrees coverage of the colon by two. The most unique feature of the CCE-2 is its adaptive frame rate (AFR). This new technology allows the CCE-2 to capture 35 images per second when in motion and 4 images per second when virtually stationary. The per-patient CCE-2 sensitivity for detecting polyps > or = 6 mm has been reported as 84%-91%. These recent advancements in this modality might offer physicians the option to screen for colorectal lesions noninvasively. PMID:24597367

  7. Automatic quantification of posterior capsule opacification

    Science.gov (United States)

    Barman, Sarah A.; Uyyanonvara, Bunyarit; Boyce, James F.; Sanguinetti, Giorgia; Hollick, Emma J.; Meacock, William R.; Spalton, David J.; Paplinski, Andrew P.

    2000-06-01

    After Cataract surgery where a plastic implant lens is implanted into the eye to replace the natural lens, many patients suffer from cell growth across a membrane situated at the back of the lens which degrades their vision. The cell growth is known as Posterior Capsule Opacification (or PCO). It is important to be able to quantify PCO so that the effect of different implant lens types and surgical techniques may be evaluated. Initial results obtained using a neural network to detect PCO from implant lenses are compared to an established but less automated method of detection, which segments the images using texture segmentation in conjunction with co- occurrence matrices. Tests show that the established method performs well in clinical validation and repeatability trials. The requirement to use a neural network to analyze the implant lens images evolved from the analysis of over 1000 images using the established co-occurrence matrix segmentation method. The work shows that a method based on neural networks is a promising tool to automate the procedure of calculating PCO.

  8. The SpaceLiner7 - Vehicle and Rescue Capsule

    OpenAIRE

    Bauer, Carola; Garbers, Nicole; Sippel, Martin

    2013-01-01

    The SpaceLiner high speed passenger transport concept has been under investigation since 2005, and during this time the geometry has changed due to the application of progressively more detailed analyses. However, from the beginning safety was seen as an important issue and as such, the idea of having a passenger capsule within the orbiter was born. In addition to the capsule, other subsystems, the thermal protection system (TPS) in particular, increase the safety of the passengers. ...

  9. Demonstration of Polysaccharide Capsule in Campylobacter jejuni Using Electron Microscopy

    OpenAIRE

    Karlyshev, Andrey V.; McCrossan, Maria V.; Wren, Brendan W.

    2001-01-01

    Recently, we reported that Campylobacter jejuni, an important gastrointestinal pathogen, has the genetic determinants to produce a capsular polysaccharide (Karlyshev et al., Mol. Microbiol. 35:529–541, 2000). Despite these data, the presence of a capsule in these bacteria has remained controversial. In this study we stain C. jejuni cells with the cationic dye Alcian blue and demonstrate for the first time by electron microscopy that C. jejuni cells produce a polysaccharide capsule that is ret...

  10. Emerging Issues and Future Developments in Capsule Endoscopy

    OpenAIRE

    Slawinski, Piotr R.; Obstein, Keith L.; Valdastri, Pietro

    2015-01-01

    Capsule endoscopy (CE) has transformed from a research venture into a widely used clinical tool and the primary means for diagnosing small bowel pathology. These orally administered capsules traverse passively through the gastrointestinal tract via peristalsis and are used in the esophagus, stomach, small bowel, and colon. The primary focus of CE research in recent years has been enabling active CE manipulation and extension of the technology to therapeutic functionality; thus, widening the s...

  11. Cytological factors relating to posterior capsule opacification following cataract surgery.

    OpenAIRE

    Jacob, T J; Humphry, R. C.; Davies, E. G.; Thompson, G M

    1987-01-01

    Simulated extracapsular cataract extractions on cadaver eyes were performed which demonstrated that the cells of the anterior capsule remain largely intact and that only a small amount of cortical lens matter remains postoperatively. Human lens epithelial cells from normal and cataractous lenses were grown in culture. There was no appreciable difference in growth rate between cells from normal and those from cataractous lenses or between equatorial and central capsule cells. The cells grew fr...

  12. Capsule-type pe biogas digester: low-cost and environment friendly system

    International Nuclear Information System (INIS)

    The Indian model of the biogas digester has been introduced in the country during the last three decades, whereas the Chinese dome-type design could not be introduced due to the skills required for construction of this digester. The other problem associated with Chinese dome-type digester is that large quantities of solid waste are needed to fill the digester. The Chinese dome-type digester constructed on experimental basis could not perform satisfactorily. The Indian Model, although popular in the country, is not environment friendly and is of high cost, both in terms of capital investment and 0 and M. It creates quite dirty environment around the digester due to the free movement of slurry. It also creates problems of mosquitoes, as the environment. is conducive for their breeding. Taking into consideration, these limitations, design of polyethylene capsule-type digester (with black carbon and UV stabilizers) was developed, using water tanks normally constructed for domestic water storage by the local plastic companies. Modification was made in the PE water tank and one of the local companies collaborated to manufacture the capsule-type digester. Solid waste is introduced from the top, whereas the slurry can be disposed from the bottom through a controlled valve. Thus input of solid waste and slurry-disposal is now within the choice of the owner. The slurry can be disposed into a tank, where it can be composted to reduce the pH, before its use for agriculture. The PE capsule-type black-color digester is also attractive for increasing the temperature of the digester due to black body absorption. The production of gas during summer season might take a few days, whereas additional greenhouse effect during winter can raise the temperature by 10 degree C. Hence, this digester is more suitable for cooler regions where the Indian model is not successful. The design is modular in nature; therefore linking additional modules in series can increase the capacity of biogas

  13. Failure of the capsule for coated particles irradiation

    International Nuclear Information System (INIS)

    During operation cycle No. 27 of the JMTR (Japan Material Testing Reactor) on May 20, 1974, leakage of the fission product gas occurred from the capsule 72F-7A, which contained coated particles for the irradiation; the coated particles are for the development of a multi-purpose high temperature gas cooled reactor. The capsule was designed for heat 16000C. Three nickel plates as the heat reflector were sandwiched in between the plates of titanium and zirconium, which were adsorbents for the impurity gases in the cladding tube (Nb-1%Zr). Temperatures of the plates were about 10000C under the irradiation, so one metal diffused into the other metal through interfaces, resulting in the formation of an alloy. Its melting point was lower than those of metals in the capsule. The cladding material Nb-1%Zr was melted by the alloy and finally a pin hole developed through the cladding. The process of failure, design of the capsule, post-irradiation test of the capsule and the failure-reproducing experiment with a mock-up capsule are described. (auth.)

  14. Design and fabrication of non-instrumented capsule

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Sung; Lee, Jeong Young; Kim, Joon Yeon; Lee, Sung Ho; Ji, Dae Young; Kim, Suk Hoon; Ahn, Sung Ho [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-04-01

    The use of non-instrumented capsule designed and fabricated in this time is for the evaluation of material irradiation performance, it is to be installed in the inner core of HANARO. The design process of non-instrumented capsule was accomplished by the decision of the quality of material and the shape, thermal analysis, structural analysis. The temperature of the specimen and the stress in capsule during irradiation test was calculated by the thermal analysis and the structural analysis. GGENGTC code and ABAQUS code were used for the calculation of non-instrumented capsule. In case of installing the capsule in irradiation hole, the coolant flow rate and the pressure drop in the hole is changed, which will affect the coolant flow rate of the fuel region. Eventually the coolant flow rate outside capsule have to be restricted to the allowable range. In order to obtain the required pressure drop, the flow rate control mechanism, end plate and orifice ring were used in this test. The test results are compared with 36-element fuel pressure drop data which AECL performed by the SCTR facility.

  15. Electromagnetic wave propagation of wireless capsule endoscopy in human body

    Institute of Scientific and Technical Information of China (English)

    LIM; Eng-Gee; 王炤; 陈瑾慧; TILLO; Tammam; MAN; Ka-lok

    2013-01-01

    Wireless capsule endoscopy(WCE) is a promising technique which has overcome some limitations of traditional diagnosing tools, such as the comfortlessness of the cables and the inability of examining small intestine section. However, this technique is still far from mature and asks for the feasible improvements. For example, the relatively low transmission data rate and the absence of the real-time localization information of the capsule are all important issues. The studies of them rely on the understanding of the electromagnetic wave propagation in human body. Investigation of performance of WCE communication system was carried out by studying electromagnetic(EM) wave propagation of the wireless capsule endoscopy transmission channel. Starting with a pair of antennas working in a human body mimic environment, the signal transmissions and attenuations were examined. The relationship between the signal attenuation and the capsule(transmitter) position, and direction was also evaluated. These results provide important information for real-time localization of the capsule. Moreover, the pair of antennas and the human body were treated as a transmission channel, on which the binary amplitude shift keying(BASK) modulation scheme was used. The relationship between the modulation scheme, data rate and bit error rate was also determined in the case of BASK. With the obtained studies, it make possible to provide valuable information for further studies on the selection of the modulation scheme and the real-time localization of the capsules.

  16. Bushen Yisui Capsule ameliorates axonal injury in experimental autoimmune encephalomyelitis

    Institute of Scientific and Technical Information of China (English)

    Ling Fang; Lei Wang; Qi Zheng; Tao Yang; Hui Zhao; Qiuxia Zhang; Kangning Li; Li Zhou; Haiyang Gong; Yongping Fan

    2013-01-01

    A preliminary clinical study by our group demonstrated Bushen Yisui Capsule (formerly cal ed Er-huang Formula) in combination with conventional therapy is an effective prescription for the treat-ment of multiple sclerosis. However, its effect on axonal injury during early multiple sclerosis re-mains unclear. In this study, a MOG 35-55-immunized C57BL/6 mouse model of experimental au-toimmune encephalomyelitis was intragastrical y administered Bushen Yisui Capsule. The results showed that Bushen Yisui Capsule effectively improved clinical symptoms and neurological function of experimental autoimmune encephalomyelitis. In addition, amyloid precursor protein expression was down-regulated and microtubule-associated protein 2 was up-regulated. Experimental findings indicate that the disease-preventive mechanism of Bushen Yisui Capsule in experimental autoim-mune encephalomyelitis was mediated by amelioration of axonal damage and promotion of rege-neration. But the effects of the high-dose Bushen Yisui Capsule group was not better than that of the medium-dose and low-dose Bushen Yisui Capsule group in preventing neurological dysfunction.

  17. Thermal analysis of an instrumented capsule using an ANSYS program

    International Nuclear Information System (INIS)

    An instrumented capsule has been used for an irradiation test of various nuclear materials in the research reactor, HANARO. To obtain the design data of the instrumented capsule, a thermal analysis is performed using a finite element analysis program, ANSYS. The 2-dimensional model for a cross section of the capsule including the specimens is generated, and a gamma-heating rate of the materials for the HANARO power of 24 or 30 MW is considered as an input force. The effect of the gap size and the control rod position on the temperature of the specimens or other components is discussed. From the analysis it is found that the gap between the thermal media and the external tube has a significant effect on the temperature of the specimen. In the case of the material capsule, the maximum temperature for the reactor power of 24 MW is 255degC for an irradiation test and 257degC for a FE analysis at the center stage of the capsule in the axial direction. It is expected that the analysis models using an ANSYS program will be useful in designing the instrumented capsules for an irradiation test and estimating the test results. (author)

  18. Simulating Space Capsule Water Landing with Explicit Finite Element Method

    Science.gov (United States)

    Wang, John T.; Lyle, Karen H.

    2007-01-01

    A study of using an explicit nonlinear dynamic finite element code for simulating the water landing of a space capsule was performed. The finite element model contains Lagrangian shell elements for the space capsule and Eulerian solid elements for the water and air. An Arbitrary Lagrangian Eulerian (ALE) solver and a penalty coupling method were used for predicting the fluid and structure interaction forces. The space capsule was first assumed to be rigid, so the numerical results could be correlated with closed form solutions. The water and air meshes were continuously refined until the solution was converged. The converged maximum deceleration predicted is bounded by the classical von Karman and Wagner solutions and is considered to be an adequate solution. The refined water and air meshes were then used in the models for simulating the water landing of a capsule model that has a flexible bottom. For small pitch angle cases, the maximum deceleration from the flexible capsule model was found to be significantly greater than the maximum deceleration obtained from the corresponding rigid model. For large pitch angle cases, the difference between the maximum deceleration of the flexible model and that of its corresponding rigid model is smaller. Test data of Apollo space capsules with a flexible heat shield qualitatively support the findings presented in this paper.

  19. Structural analysis for the HANARO irradiation capsule through vibration test

    International Nuclear Information System (INIS)

    Instrumented capsules are one of the irradiation facilities in the HANARO core. The capsule is a cylindrical shape, and it has the outside diameter of 60 mm and length of 877 mm. This structure is subject to flow-induced vibration (FIV) due to the flow of the primary coolant and then the structural integrity of the capsule during irradiation in the reactor is issue of major concern. However, the complexity of coolant flow in the forced convection area of the reactor, it is very difficult to obtain directly the flow-induced loads acting on the capsule structure. For this purpose the acceleration was measured by four accelerometers attached to the protection tube of the capsule. Based on the measured data, the displacement at the top part of the capsule mainbody and the displacement between flow tubes were calculated using commercial finite element program ANSYS to evaluate the structural interference to the neighboring flow tubes under the reactor operating condition. The calculated displacement at the region of the flow tube are lower than the values in allowable design criteria

  20. Design and fabrication of non-instrumented capsule

    International Nuclear Information System (INIS)

    The use of non-instrumented capsule designed and fabricated in this time is for the evaluation of material irradiation performance, it is to be installed in the inner core of HANARO. The design process of non-instrumented capsule was accomplished by the decision of the quality of material and the shape, thermal analysis, structural analysis. The temperature of the specimen and the stress in capsule during irradiation test was calculated by the thermal analysis and the structural analysis. GGENGTC code and ABAQUS code were used for the calculation of non-instrumented capsule. In case of installing the capsule in irradiation hole, the coolant flow rate and the pressure drop in the hole is changed, which will affect the coolant flow rate of the fuel region. Eventually the coolant flow rate outside capsule have to be restricted to the allowable range. In order to obtain the required pressure drop, the flow rate control mechanism, end plate and orifice ring were used in this test. The test results are compared with 36-element fuel pressure drop data which AECL performed by the SCTR facility

  1. Capsule Development and Utilization for Material Irradiation Tests

    International Nuclear Information System (INIS)

    The objective of this project was to establish basic capsule irradiation technology using the multi-purpose research reactor [HANARO] to eventually support national R and D projects of advanced fuel and materials related to domestic nuclear power plants and next generation reactors. There are several national nuclear projects in KAERI, which require several irradiation tests to investigate in-pile behavior of nuclear reactor fuel and materials for the R and D of several types of fuels such as advanced PWR and DUPIC fuels and for the R and D of structural materials such as RPV(reactor pressure vessel) steel, Inconel, zirconium alloy, and stainless steel. At the moment, internal and external researchers in institutes, industries and universities are interested in investigating the irradiation characteristics of materials using the irradiation facilities of HANARO. For these kinds of material irradiation tests, it is important to develop various capsules using our own techniques. The development of capsules requires several leading-edge technologies and our own experiences related to design and fabrication. In the second phase from April 1,2000 to March 31, 2003, the utilization technologies were developed using various sensors for the measurements of temperature, pressure and displacement, and instrumented capsule technologies for the required fuel irradiation tests were developed. In addition, the improvement of the existing capsule technologies and the development of an in-situ measurable creep capsule for specific purposes were done to meet the various requirements of users

  2. Chinese restaurant syndrome

    Science.gov (United States)

    Chinese restaurant syndrome is a set of symptoms that some people have after eating Chinese food. A food additive ... Chinese restaurant syndrome is most often diagnosed based on the symptoms. The health care provider may ask the following ...

  3. CHINESE JOURNAL OF CHEMISTRY

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    @@Chinese Journal of Chemistry is an international journal published in English by the Chinese Chemical Society with its editorial office hosted by Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences.

  4. Chinese Culture and Leadership.

    Science.gov (United States)

    Wong, Kam-Cheung

    2001-01-01

    Describes essential characteristics of Chinese philosophical tradition; Discusses Western perspectives on value leadership in education, particularly moral leadership. Discuses moral leadership from a Chinese philosophical perspective, especially Confucianism. Draws implications for using Chinese cultural and philosophical traditions to develop…

  5. Karyotype and DNA-Methylation Responses in Myelodysplastic Syndromes following Treatment with Traditional Chinese Formula Containing Arsenic

    OpenAIRE

    Sun Shuzhen; Ma Rou; Hu Xiaomei; Yang Xiao-hong; Xu Yong-gang; Wang Hongzhi; Yang Xiu-Peng

    2012-01-01

    We have previously shown that arsenic-containing Chinese herbal formula, Qing-Huang powder capsule (containing tetraarsenic tetrasulfide, As4S4), is effective in the treatment of myelodysplastic syndrome (MDS); yet the underlined mechanisms remain unclear. In this study, using standard cytogenetic analysis (G-banded) and global DNA methylation method (ChIP-on-chip assays), we aimed to determine the effect of arsenic-containing Chinese herbal formula on karyotype status and the genomic methyla...

  6. Effect of compound preparation Tongqiao Jiannao capsules on neural cell apoptosis and Bcl-2 and Bax protein levels in a rat model of brain ischemia/reperfusion injury

    Institute of Scientific and Technical Information of China (English)

    Rui Wang; Guanglai Li; Wei Wang; Huanying Li

    2008-01-01

    BACKGROUND: Pharmacological studies have demonstrated that compound preparation Tongqiao Jiannao capsules composed of Zexie, Baizhu, Honghua, Danshen, and Shexiang can supplement qi,activate blood circulation, relieve blood stasis, induce resuscitation for alleviating pain, relieve pain, anddilate blood vessels.OBJECTIVE: To observe the effects of Tongqiao Jiannao capsules on the levels of the anti-apoptotic protein Bcl-2 and the pro-apoptotic protein Bax, and verify the mechanism of action.DESIGN, TIME AND SETTING: Randomized, controlled animal experiment, performed in the Laboratory of Biochemistry and Molecular Biology, Shanxi Medical University between June 2001 and December 2002.MATERIALS: The right middle cerebral arteries of 24 healthy adult Sprague Dawley rats were occluded by the suture method. The primary Chinese herbal medicinal ingredients of Tongqiao Jiannao capsules are Zexie. Baizhu, Honghua, Danshen, and Shexiang, which were purchased from Shanxi Provincial Medicinal Material Company, China, and prepared into condensed granules in the Room for Chinese Herbal Medicine Preparation, Second Hospital, Shanxi Medical University. Bcl-2 and Bax immunohistochemical staining kits, a 3,3-diaminobenzidine(DAB) kit, and an in situ apoptosis detection kit were purchased from Wuhan Boster Bioengineering Co., Ltd., China.METHODS: Twenty-four rats were randomly and evenly divided into three groups: (1) sham-operated rats in which sutures were inserted and immediately pulled out; (2) Tongqiao Jiannao capsule-treated rats that were intragastrically administered 6.5 g/kg/d Tongqiao Jiannao capsule preparation for seven successive days prior to middle cerebral artery occlusion (MCAO); and (3) MCAO rats without any other treatments.MAIN OUTCOME MEASURES: The levels of neural cell apoptosis and Bcl-2 and Bax proteins at 24 hours post-surgery.RESULTS: In the MCAO group, the numbers of apoptotic cells and Bax-positive cells were significantly increased, while the numbers of

  7. Evaluation of slim-edge, multi-guard, and punch-through-protection structures before and after proton irradiation

    International Nuclear Information System (INIS)

    Planar geometry silicon pixel and strip sensors for the high luminosity upgrade of the LHC (HL-LHC) require a high bias voltage of 1000 V in order to withstand a radiation damage caused by particle fluences of 1×1016 1 MeV neq/cm2 and 1×1015 1 MeV neq/cm2 for pixel and strip detectors, respectively. In order to minimize the inactive edge space that can withstand a bias voltage of 1000 V, edge regions susceptible to microdischarge (MD) should be carefully optimized. We fabricated diodes with various edge distances (slim-edge diodes) and with 1–3 multiple guard rings (multi-guard diodes). AC coupling insulators of strip sensors are vulnerable to sudden heavy charge deposition, such as an accidental beam splash, which may destroy the readout AC capacitors. Thus various types of punch-through-protection (PTP) structures were implemented in order to find the most effective structure to protect against heavy charge deposition. These samples were irradiated with 70 MeV protons at fluences of 5×1012 1 MeV neq/cm2–1×1016 1 MeV neq/cm2. Their performances were evaluated before and after irradiation in terms of an onset voltage of the MD, a turn-on voltage of the PTP, and PTP saturation resistance. -- Highlights: ► We have evaluated radiation tolerance of n-in-p sensors up to 1×1016 1 MeV neq/cm2. ► Both n-bulk and p-bulk require a field width≥450 μm in order to withstand 1000 V. ► The MD onset voltage was found to be independent of the edge width. ► With increasing number of guard rings, bias voltage tolerance improved before irrad. ► BZ4D-5 (with full extension) performs the best among the samples.

  8. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants

    International Nuclear Information System (INIS)

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  9. The Chinese Banking System

    OpenAIRE

    Grant Turner; Nicholas Tan; Dena Sadeghian

    2012-01-01

    The Chinese banking system is critical to the functioning of the Chinese economy, being the main conduit through which savings are allocated to investment opportunities. Banking activity in China has grown rapidly over the past decade in association with the expansion of the Chinese economy, and the Chinese banking system now includes some of the world’s largest banks. Chinese banks have become more commercially orientated over this period, although the Chinese Government retains considerable...

  10. Effects of Guchang Capsule on Dextran Sulphate Sodium-Induced Experimental Ulcerative Colitis in Mice

    Science.gov (United States)

    Liu, Baoshan; Liu, Tong; Wang, Xiaohong; Zheng, Xin; Wang, Hong; Ma, Lin

    2016-01-01

    Guchang capsule (GC) is a Chinese materia medica standardized product extracted from 15 Chinese traditional medical herbs and it has been clinically used in the treatment of intestinal disease. In this study, in order to extend the research of GC in intestinal disease, we were aiming to evaluate potential effects of GC on dextran sulphate sodium- (DSS-) induced murine experimental colitis and to elucidate the underlying mechanisms. GC treatment attenuated DSS-induced body weight loss and reduced the mortality. Moreover, GC treatment prevented DSS-induced colonic pathological damage; meanwhile it inhibited proinflammatory cytokines production in colon tissues. In vitro, GC significantly reduced LPS-induced proinflammatory cytokines production via inhibiting the activation of NF-κB in macrophage cells, and the expressions of several long noncoding RNAs (lncRNAs) which were reported in regulating NF-κB signaling pathway were obviously affected by adding GC into culture medium. In conclusion, our data suggested that administration of GC exhibits therapeutic effects on DSS-induced colitis partially through regulating the expression of NF-κB related lncRNAs in infiltrating immune cells. PMID:27313642

  11. The study of bioavailability and bioequivalence of oseltamivir in Chinese health volunteers

    Institute of Scientific and Technical Information of China (English)

    LI Jing-lai; CUI Meng-cun; WANG Xiao-ying; QIAO Jian-zhong; YUAN Su-lan; ZHANG Zhen-qing; RUAN Jin-xiu; ZHONG Wu; LI Song

    2008-01-01

    Objective To evaluate the bioavailability and bioequivalence of oseltamivir capsule in Chinese health male volunteers. Methods A randomized, two period, two treatment, two sequence crossover bioequivalence trial was designed, 24 Chinese health volunteers were randomly divided into two groups, each group was orally given single dose oseltamivir phosphate (tamifla) or AMMS 607 capsule. The active metabolite oseltamivir carboxylate of oseltamivir in the plasma were determined by liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method. The pharmacokinetics parameters and relative bioavailability were calculated to evaluate the bioequivalence of AMMS 607 and tamifla. Results Cmax of the AMMS 607 and tamifla were 602.07±153.27 ng·mL-1 and 620.09±132.39 ng·mL-1 respectively; tmax were 4.2± 1.1 h and 4.8±1.0 h; t1/2β were 6.60±0.87 h and 6.61±0.83 h;MRT were 10.00±1.77 h and 10.40 ±1.62 h; AUC0-24 were 6285.88±1083.66 ng·h·mL-1 and 6546.01±1199.32 ng·h·mL-1; Compared with the reference of tamifla capsule, the bioavailability F0-tn of AMMS 607 capsule was 99.5±27.7 %. The main pharmacokinetics parameters of AUC0-24, Cmax and Tmax showed no statistically significant difference between the two capsules. Conclusions The AMMS 607 capsule and tamifla capsule are bioequivalent.

  12. 小井眼筛管悬挂器的研制与应用%Development and application of sieve tube hanger in slim hole

    Institute of Scientific and Technical Information of China (English)

    赵峨松; 陈娟琪

    2012-01-01

    为增大防砂结构内通径尺寸,实现(O)101.6mm套管出砂小井眼油气井机械防砂,研制了小井眼专用筛管悬挂器,采用坐封、丢手动力装置与悬挂装置分开的独立设计,使悬挂器丢手后内通径为56mm,突破了传统卡瓦式封隔器最大通径36mm的设计极限.试验表明,该悬挂器使用方便,地面投球打压即可完成坐封、丢手,能实现悬挂器内冲砂,可配合筛管实现小井眼机械防砂工艺和小井眼复合防砂工艺,为解决小井眼出砂治理难题提供了一种新思路,具有广阔的应用前景.%In order to increase the inner diameter of the sand control device and realize mechanical sand control in oil & gas wells with the casing of 0101.6 mm, a special sieve tube hanger used in slim hole is developed. By separately designing block letter, lost hand power device and hanger implement, the inner diameter of hanger after lost hand is up to 56 mm which is a breakthrough in designing traditional slip packer with limit diameter of 036 mm. Ground test and field application show that the hanger is easy using, and can immediately finish set sealing and lost hand by putting steel ball and increasing the pressure on the ground. By constructing the hanger washed sand measure in the hanger, mechanical sand control technology and slim hole compound sand control process can be realized in slim hole companying with screen. The success provides a new measure to solve sand problem in slim hole and has broad application prospects in the future.

  13. Analytical Quality check of oil based blend in Flaxilip capsule

    Directory of Open Access Journals (Sweden)

    Rajashree Rane

    2014-12-01

    Full Text Available Analysis of capsules containing blend in the powder form is easy, but it is bit difficult to analyse the soft gelatin capsule containing oil based blend. The purpose of this study was to develop test parameters to determine and supervise the quality of such herbal capsule formulation. Five different lots of soft gelatin Flaxilip capsule containing Linseed oil, Guggulu processed with linseed oil, Garlic oil, Fenugreek oil along with Soyabean oil as an excipient , were selected for the study. All the five lots were subjected to general capsule tests such as determination of average weight and disintegration time. Results obtained were around 1.3500g and 10minutes respectively. Specific test parameters applicable for oils like specific gravity, refractive index, acid value, peroxide value, saponification value, iodine value were applied quantitatively for quality evaluation. Standardised suitable classical methods were applied. Results in all the five lots were found to be well within inhouse limit. All the samples were subjected to heavy metals and microbiological testing. Compliance of corresponding findings with the standard pharmacopoeial guidelines assure the safe intake of the drug. For getting the better effect, the Guggulu that is Commiphora mukul used in the formulation was processed with linseed oil. Its presence was confirmed by carrying out HPTLC for E and Z guggulu sterone. Resemblance of spots at Rf ranging from 0.36 to 0.38 and 0.43 to 0.45 in Toluene : Acetone (9:1 system showed the presence of gugulu in blends of all the lots. Hence by applying all these test parameters one can ensure the quality of the soft gelatin ayurvedic capsule formulation containing oily base like in Flaxilip capsule.

  14. Chinese Calendar and Chinese Telegraphic Code.

    Science.gov (United States)

    Defense Language Inst., Monterey, CA.

    This manual contains: (1) Chinese calendars for the hundred years from 1881 to 1980; and (2) the Chinese telegraphic code. Each page in Part One presents the calendar for each year in both Chinese and English. There are 97 charts in Part Two representing the telegraphic code. (AMH)

  15. Final Report of the Surveillance Capsules Fabrication and Installation of KORI UNIT 1

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bong Sang; Lee, Ho Jin; Kim, Min Chul; Yoon, Ji Hyun; Choi, Kwon Jae; Kim, Ki Baik; Kim, Jong Min; Yoo, Choon Sung; Lee, Sam Lai; Gong, Un Sik [KAERI, Daejeon (Korea, Republic of)

    2011-08-15

    Additional surveillance capsules are needed for monitoring irradiation embrittlement of Kori-1 RPV during the continued operation period. New surveillance capsule specimens were machined from the reserved original archive materials. The capsule was fabricated by the original supplier Westinghouse. The surveillance capsule meets the requirement of MEST Bulletin 2009-37, Appendix H of USNRC 10CFR50 and ASTM E185. The installation of the new capsule(A) and the reserved capsule(N) into the capsule holder outside of the thermal shield of Kori-1 RPV were completed on January 20, 2011, in cooperation with KAERI, KRIST, KPS and Westinghouse. The locations of the new capsule(A) and the reserved capsule(N) are R(77 .deg.) and V(257 .deg.), respectively

  16. Final Report of the Surveillance Capsules Fabrication and Installation of KORI UNIT 1

    International Nuclear Information System (INIS)

    Additional surveillance capsules are needed for monitoring irradiation embrittlement of Kori-1 RPV during the continued operation period. New surveillance capsule specimens were machined from the reserved original archive materials. The capsule was fabricated by the original supplier Westinghouse. The surveillance capsule meets the requirement of MEST Bulletin 2009-37, Appendix H of USNRC 10CFR50 and ASTM E185. The installation of the new capsule(A) and the reserved capsule(N) into the capsule holder outside of the thermal shield of Kori-1 RPV were completed on January 20, 2011, in cooperation with KAERI, KRIST, KPS and Westinghouse. The locations of the new capsule(A) and the reserved capsule(N) are R(77 .deg.) and V(257 .deg.), respectively

  17. Production of 131-I iodide capsules in Argentina

    International Nuclear Information System (INIS)

    It is well known that 131I iodide capsules are better suited to be taken by the patient than the corresponding solution. Therefore most Pharmacopeias have monographs for 131I in both pharmaceutical forms: solution or capsules, for diagnosis but principally for therapeutic purposes. In Argentina this radiopharmaceutical has been made commercially available in November 2007. At this time Bacon Laboratories SAIC started its production, authorized by the Health and Nuclear Regulatory Authorities. 131I, in the pharmaceutical form of capsules, have evident advantages in radioprotection for the patients and the personnel involved in its administration. The intake of a 131I provokes frequently that the external part of the mouth (principally if there is a beard and/or a moustache) undergoes an external contamination. This problem is enhanced if the patient has some motor difficulties to take the glass with the solution. In this case he will need assistance from the medical or technical staff, who will receive a much greater radiation dose than in normal cases. In the capsule of 131I iodide, the solution is adsorbed on a sodium phosphate matrix. The capsule is in a plastic tube contained in an appropriate lead shielding. To take the capsule, the patient inclines the open lead shielding containing the capsule in the direction of the mouth. Once the capsule is in the mouth it is swallowed with a little portion of water. After its intake, the radiopharmaceutical is absorbed from the gastrointestinal tract. If a patient is unable to carry out the intake, the assistance by medical or technical staff is easy with practically no radiation harm, since the 131I is shielded by an adequate lead thickness. It is evident that the hands and external face of the patient are also protected since no possibility of contamination exists. The aim of this work is to present the production procedure, the packaging of the capsules and the decrease of the dose received by the involved personnel

  18. Capsule endoscopy in the diagnosis of Crohn’s disease

    Directory of Open Access Journals (Sweden)

    Niv Y

    2013-05-01

    Full Text Available Yaron NivDepartment of Gastroenterology, Rabin Medical Center, Tel Aviv University, Petah Tikva, IsraelAbstract: Crohn’s disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn’s disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn’s disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn’s disease. Recently, we have developed and validated the Capsule Endoscopy Crohn’s Disease Activity Index (also known as the Niv score for Crohn’s disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn’s ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing

  19. Finding the solution for incomplete small bowel capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    José; Cotter; Francisca; Dias; de; Castro; Joana; Magalhes; Maria; Joo; Moreira; Bruno; Rosa

    2013-01-01

    AIM:To evaluate whether the use of real time viewer(RTV)and administration of domperidone to patients with delayed gastric passage of the capsule could reduce the rate of incomplete examinations(IE)and improve the diagnostic yield of small bowel capsule endoscopy(SBCE).METHODS:Prospective single center interventional study,from June 2012 to February 2013.Capsule location was systematically checked one hour after ingestion using RTV.If it remained in the stomach,the patient received 10 mg domperidone per os and the location of the capsule was rechecked after 30 min.If the capsule remained in the stomach a second dose of10 mg of domperidone was administered orally.After another 30 min the position was rechecked and if the capsule remained in the stomach,it was passed into the duodenum by upper gastrointestinal(GI)endoscopy.The rate of IE and diagnostic yield of SBCE were compared with those of examinations performed before the use of RTV or domperidone in our Department(control group,January 2009-May 2012).RESULTS:Both groups were similar regarding age,sex,indication,inpatient status and surgical history.The control group included 307 patients,with 48(15.6%)IE.The RTV group included 82 patients,with3(3.7%)IE,P=0.003.In the control group,average gastric time was significantly longer in patients with IE than in patients with complete examination of the small bowel(77 min vs 26 min,P=0.003).In the RTV group,the capsule remained in the stomach one hour after ingestion in 14/82 patients(17.0%)vs 48/307(15.6%)in the control group,P=0.736.Domperidone did not significantly affect small bowel transit time(260min vs 297 min,P=0.229).The capsule detected positive findings in 39%of patients in the control group and 49%in the RTV group(P=0.081).CONCLUSION:The use of RTV and selective administration of domperidone to patients with delayed gastric passage of the capsule significantly reduces incomplete examinations,with no effect on small bowel transit time or diagnostic yield.

  20. FEM analysis of escape capsule suffered to gas explosion

    Science.gov (United States)

    Li, Chang-lu; Mei, Rui-bin; Li, Chang-sheng; Cai, Ban; Liu, Xiang-hua

    2013-05-01

    Escape capsules are new devices for underground coal mines that provide air, water, food and supplies in the event of an emergency in where miners are unable to escape. It is difficult to carry out the experiments of explosion and safety because the danger and nonrepeatability of explosion. The structure deformation and distribution of equivalent stress has been investigated under different impact pressure conditions including unimodal and bimodal loads based on the FEM and software LS-DYNA. The results show that the distribution of deformation and equivalent stress has the same trend on the same surface with the increment of explosion pressure. The deformation and stress are larger with side impact pressure compared with that of the same front impact pressure. Furthermore, the maximum equivalent stress is 246MPa and 260MPa on the front and sides of capsule with five times for national standard impact pressure 1.5MPa. Under these conditions, the deformation is less than about 9.97mm and 10.47mm, respectively. When the front impact pressure is 2.0MPa, the deformation of capsule still belongs to elasticity but the less plastic deformation occurs on the Ushape stiffening channels with the same side impact pressure. However, it is safe for capsule structure because the equivalent stress 283MPa is much less than the tensile strength. It is noted that bimodal load accelerates the capsule deformation so that it is more dangerous compared with unimodal load.

  1. Wireless powered capsule endoscopy for colon diagnosis and treatment

    International Nuclear Information System (INIS)

    This paper presents a wireless power transfer system integrated with an active locomotion and biopsy module in an endoscopic capsule for colon inspection. The capsule, which can move automatically, is designed for non-invasive biopsy and visual inspection of the intestine. To supply enough power for multiple functions and ensure safety for the human body, the efficiency of the current power transmission system needs to be improved. To take full advantage of the volume in the capsule body, a novel structure of receiving coils wound on a multi-core of MnZn ferrite hollow cylinder was used; with this new core, the efficiency increased to more than 7.98%. Up to 1.4 W of dc power can be delivered to the capsule as it travels along the gastrointestinal tract. Three micro motors were integrated for pumping, anchoring, locomotion and biopsy. A user interface and RF communication enables the operator to drive the capsule in an intuitive manner. To gauge the efficacy of the wireless power supply in a simulated real-world application, the biopsy and locomotion capabilities of the device were successfully tested in a slippery, soft tube and gut environment in vitro. (paper)

  2. Thermohydraulic design of saturated temperature capsule for IASCC irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Ide, Hiroshi; Matsui, Yoshinori; Itabashi, Yukio [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2002-10-01

    An advanced water chemistry controlled irradiation research device is being developed in JAERI, to perform irradiation tests for irradiation assisted stress corrosion cracking (IASCC) research concerned with aging of LWR. This device enables the irradiation tests under the water chemistry condition and the temperature, which simulate the conditions for BWR core internals. The advanced water chemistry controlled irradiation research device is composed of saturated temperature capsule inserted into the JMTR core and the water chemistry control unit installed in the reactor building. Regarding the saturated temperature capsule, the Thermohydraulic design of capsule structure was done, aimed at controlling the specimen's temperature, feeding water velocity on specimen's surface to the environment of BWR nearer. As the result of adopting the new capsule structure based on the design study, it was found out that feeding water velocity at the surface of specimen's is increased to about 10 times as much as before, and nuclear heat generated in the capsule components can be removed safely even in the abnormal event such as the case of loss of feeding water. (author)

  3. Entry Trajectory Issues for the Stardust Sample Return Capsule

    Science.gov (United States)

    Desai, Prasun N.; Mitcheltree, Robert A.; Cheatwood, F. McNeil

    1999-01-01

    The Stardust mission was successfully launched on February 7, 1999. It will be the first mission to return samples from a comet. The sample return capsule, which is passively controlled during the fastest Earth entry ever, will land by parachute in Utah. The present study describes the analysis of the entry, descent, and landing of the returning sample capsule utilizing the final, launch configuration capsule mass properties. The effects of two aerodynamic instabilities are revealed (one in the high altitude free molecular regime and the other in the transonic/subsonic flow regime). These instabilities could lead to unacceptably large excursions in the angle-of-attack near peak heating and main parachute deployment, respectively. To reduce the excursions resulting from the high altitude instability, the entry spin rate of the capsule is increased. To stabilize the excursions from the transonic/subsonic instability, a drogue chute with deployment triggered by a gravity-switch and timer is added prior to main parachute deployment. A Monte Carlo dispersion analysis of the modified entry (from which the impact of off-nominal conditions during the entry is ascertained) predicts that the capsule attitude excursions near peak heating and drogue chute deployment are within Stardust mission limits. Additionally, the size of the resulting 3-sigma landing ellipse is 60.8 km in downrange by 19.9 km in crossrange, which is within the Utah Test and Training Range boundaries.

  4. FTIR-ATR imaging of coated oil capsules

    International Nuclear Information System (INIS)

    Complete text of publication follows. Coated oil capsules are used to deliver new functional food ingredients. In this study spherical capsules were investigated containing a core with fish oil coated with a transparent gelatine layer. The remaining actives are within a hard coating, which is applied on the gelatine capsules. For the microstructural characterization of the coating the following techniques were used: Fourier Transform Infrared (FTIR) microscopy using an Attenuated Total Reflection (ATR) crystal, Light Microscopy (LM), X-ray microtomography (μCT) and Scanning Electron Microscopy (SEM). For FTIR-ATR imaging the oil capsules were embedded in epoxy resin. The embedded sample was trimmed in a microtome using a glass knife for the initial rough trimming. For the final fracture a diamond knife was used to obtain the best possible surface. A Ge-crystal was brought in contact with the surface of interest. LM images were obtained using the visible light camera of the FTIR system. A principal component analysis was performed on the FTIR-ATR imaging showing the spatial distribution of some of the compounds. This study demonstrated that imaging techniques can be used to analyse the microstructure of coated oil capsules. Correlative microscopy of techniques like FTIR-ATR imaging, LM, XRT and SEM-EDX results in useful information about the spatial distribution of the chemical compounds and layer thickness of solid food samples.

  5. Analyses of copper from a prototype capsule 5 and 6

    International Nuclear Information System (INIS)

    'Prototype' is a series of experiments where SKB, the Swedish Nuclear Fuel and Waste Management Co, expose the full scale copper canisters under conditions intended to be representative of a repository for spent nuclear fuel, however, without radioactivity (SKB 2012) . Copper from one of these installations, deposition 5, has been studied for corrosion . Samples were also taken from the capsule that had been exposed in deposition 6. Drill cores across the capsule wall has been documented regarding microstructure. All samples have been exposed for about seven years in the prototype repository. Studies carried out leads to the following conclusions: Regarding the ring on top of the capsule from the deposition 5; There are local corrosion with a depth of 3-5 microns. The general or uniform corrosion that has occurred can not be quantified. The relatively sharp traces of processing of the material before exposure indicates that the general corrosion was minor. Small amounts of corrosion product has been detected in surface analysis. The surface profile on the copper surface, aside from the grooves after processing and areas of local corrosion, are relatively even. Metallographic examination of cross section shows no tendency to pitting or intergranular corrosion. Analysis for hydrogen by melting a quantity of metal does not show any increased hydrogen content. Regarding the material of the capsule from the deposition 6: The capsule has not been specifically tested for corrosion. Cross sections of drill cores through the copper canister has been documented and metallo graphically exhibits nothing remarkable

  6. Wireless powered capsule endoscopy for colon diagnosis and treatment.

    Science.gov (United States)

    Chen, Wenwen; Yan, Guozheng; He, Shu; Ke, Quan; Wang, Zhiwu; Liu, Hua; Jiang, Pingping

    2013-11-01

    This paper presents a wireless power transfer system integrated with an active locomotion and biopsy module in an endoscopic capsule for colon inspection. The capsule, which can move automatically, is designed for non-invasive biopsy and visual inspection of the intestine. To supply enough power for multiple functions and ensure safety for the human body, the efficiency of the current power transmission system needs to be improved. To take full advantage of the volume in the capsule body, a novel structure of receiving coils wound on a multi-core of MnZn ferrite hollow cylinder was used; with this new core, the efficiency increased to more than 7.98%. Up to 1.4 W of dc power can be delivered to the capsule as it travels along the gastrointestinal tract. Three micro motors were integrated for pumping, anchoring, locomotion and biopsy. A user interface and RF communication enables the operator to drive the capsule in an intuitive manner. To gauge the efficacy of the wireless power supply in a simulated real-world application, the biopsy and locomotion capabilities of the device were successfully tested in a slippery, soft tube and gut environment in vitro. PMID:24149981

  7. Improvement and utilization of irradiation capsule technology in HANARO

    International Nuclear Information System (INIS)

    Several improvements of irradiation capsule technology regarding irradiation test parameters, such as temperature and neutron flux/fluence, and regarding instrumentation have progressed at HANARO since the last KAERI-JAERI joint seminar held in 2008. The standard HANARO capsule technology that was developed for use in a commercial power plant temperature of about 300degC was improved to apply to a temperature range of 100-1000degC for the irradiation test of materials of new research reactors and future nuclear systems. Low-flux and long-term irradiation technologies have been developed at HANARO. As a beginning step of the localization of capsule instrumentation technology, the irradiation performance of a domestically produced thermocouple and LVDT will be examined at HANARO. The accuracy of an evaluation of neutron fluence and precise welding technology are also being examined at HANARO. Based on these accumulated capsule technologies, a HANARO irradiation capsule system is being actively utilized for the national R and D programme on commercial nuclear reactors and nuclear fuel cycle technology in Korea. HANARO has recently started the irradiation support of R and D relevant to future nuclear systems including SMART, VHTR, and SFR, and HANARO is preparing new support relevant to new research and Fusion reactors. (author)

  8. Biomechanics of the Hip Capsule and Capsule Management Strategies in Hip Arthroscopy.

    Science.gov (United States)

    Nepple, Jeffrey J; Smith, Matthew V

    2015-12-01

    Recent advances in our understanding of the function of the hip capsule have clarified its importance to normal hip function and kinematics. The iliofemoral ligament is the primary stabilizing structure for controlling anterior translation and external rotation of the hip, and is violated by the arthroscopic interportal capsulotomy. Microinstability of the hip occurring after surgical trauma remains a poorly defined clinical entity. In certain at-risk populations, capsular repair should be considered as part of an arthroscopic hip procedure to achieve optimal outcomes and avoid iatrogenic instability (dislocation or microinstability). Despite a lack of conclusive evidence-based indications, we recommend capsular repair in the settings of borderline hip dysplasia (or dysplastic variants such as increased femoral anteversion), hip hypermobility, connective tissue disorders, and traumatic or atraumatic instability. With careful attention to arthroscopic capsular management, adequate exposure can be achieved and reproducibly allow for an effective capsular repair when indicated. PMID:26524549

  9. Comparison of three development approaches for Stationary Phase Optimised Selectivity Liquid Chromatography based screening methods Part I: A heterogeneous group of molecules (slimming agents in food supplements).

    Science.gov (United States)

    Deconinck, E; Ghijs, L; Kamugisha, A; Courselle, P

    2016-02-01

    Three approaches for the development of a screening method to detect adulterated dietary supplement, based on Stationary Phase Optimised Selectivity Liquid Chromatography were compared for their easiness/speed of development and the performance of the optimal method obtained. This comparison was performed for a heterogeneous group of molecules, i.e. slimming agents (Part I) and a group of structural analogues, i.e. PDE-5 inhibitors (Part II). The first approach makes use of primary runs at one isocratic level, the second of primary runs in gradient mode and the third of primary runs at three isocratic levels to calculate the optimal combination of segments of stationary phases. In each approach the selection of the stationary phase was followed by a gradient optimisation. For the slimming agents, the heterogeneous group of molecules, the method obtained with the first approach was selected as optimal, based on the speed of development and the performance of the method. The method shows a good separation of the compounds, allowing the screening to be performed with diode array detection, and is fully compatible with mass spectrometry. The method was validated for its selectivity following the guidelines as described for the screening of pesticide residues and residues of veterinary medicines in food. PMID:26653480

  10. Investigation of six bioactive anthraquinones in slimming tea by accelerated solvent extraction and high performance capillary electrophoresis with diode-array detection.

    Science.gov (United States)

    Wang, Ning; Su, Ming; Liang, Shuxuan; Sun, Hanwen

    2016-05-15

    A rapid and effective method for effective separation and rapid simultaneous determination of six bioactive anthraquinones by capillary zone electrophoresis was developed. An accelerated solvent extraction procedure was used for the extraction of anthraquinones from slimming tea. Under the optimized conditions, the effective separation of six anthraquinones was achieved within 8 min. Good linearity was achieved, with a correlation coefficient (r) of ⩾ 0.999. The limit of detection ranged from 0.33 to 1.40 μg mL(-1). The intra- and inter-day relative standard deviation (RSD) of the six analytes was in the range of 2.3-3.9% and 3.2-4.9%, respectively. The average recovery of the six analytes from real tea samples was in the range of 86.15-98.30% with the RSD of 1.04-4.99%. The developed and validated method has speediness, high sensitivity, recovery and precision, and can be applied for the quality control of slimming tea. PMID:26775937

  11. Recovery Act. Sub-Soil Gas and Fluid Inclusion Exploration and Slim Well Drilling, Pumpernickel Valley, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Fairbank, Brian D. [Nevada Geothermal Power Company, Las Vegas, NV (United States)

    2015-03-27

    Nevada Geothermal Power Company (NGP) was awarded DOE Award DE-EE0002834 in January 2010 to conduct sub-soil gas and fluid inclusion studies and slim well drilling at its Black Warrior Project (now known as North Valley) in Washoe and Churchill Counties, Nevada. The project was designed to apply highly detailed, precise, low-cost subsoil and down-hole gas geochemistry methods from the oil and gas industry to identify upflow zone drilling targets in an undeveloped geothermal prospect. NGP ran into multiple institutional barriers with the Black Warrior project relating to property access and extensive cultural survey requirement. NGP requested that the award be transferred to NGP’s Pumpernickel Valley project, due to the timing delay in obtaining permits, along with additional over-budget costs required. Project planning and permit applications were developed for both the original Black Warrior location and at Pumpernickel. This included obtaining proposals from contractors able to conduct required environmental and cultural surveying, designing the two-meter probe survey methodology and locations, and submitting Notices of Intent and liaising with the Bureau of Land Management to have the two-meter probe work approved. The award had an expiry date of April 30, 2013; however, due to the initial project delays at Black Warrior, and the move of the project from Black Warrior to Pumpernickel, NGP requested that the award deadline be extended. DOE was amenable to this, and worked with NGP to extend the deadline. However, following the loss of the Blue Mountain geothermal power plant in Nevada, NGP’s board of directors changed the company’s mandate to one of cash preservation. NGP was unable to move forward with field work on the Pumpernickel property, or any of its other properties, until additional funding was secured. NGP worked to bring in a project partner to form a joint venture on the property, or to buy the property. This was unsuccessful, and NGP notified

  12. Evaluation of slim-edge, multi-guard, and punch-through-protection structures before and after proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Mitsui, S., E-mail: smitsui@post.kek.jp [The Graduate University for Advanced Studies (SOKENDAI), 1-1 Oho, Tsukuba-shi, Ibaraki-ken 305-0801 (Japan); Unno, Y.; Ikegami, Y.; Takubo, Y.; Terada, S. [Institute of Particle and Nuclear Study, High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba-shi, Ibaraki-ken 305-0801 (Japan); Hara, K.; Takahashi, Y. [Institute of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennoudai, Tsukuba-shi, Ibaraki 305-8571 (Japan); Jinnouchi, O.; Nagai, R.; Kishida, T. [Department of Physics, Tokyo Institute of Technology, 2-12-1 Okayama, Meguro-ku, Tokyo 152-8550 (Japan); Yorita, K. [Research Institute for Science and Engineering, Waseda University, 1-6-1 Nishi-Waseda, Shinjuku-ku, Tokyo 169-8050 (Japan); Hanagaki, K [Department of Physics, Osaka University, Machikaneyama-cho, Toyonaka-shi, Osaka 560-0043 (Japan); Takashima, R. [Department of Education, Kyoto University of Education, 1 Fukakusa-Fujimori-cho, Fushimi-ku, Kyoto 612-8522 (Japan); Kamada, S.; Yamamura, K. [Solid-state Division, Hamamatsu Photonics K.K., 1126-1 Ichino-cho, Higashi-ku, Hamamatsu-shi, Shizuoka 435-8558 (Japan)

    2013-01-21

    Planar geometry silicon pixel and strip sensors for the high luminosity upgrade of the LHC (HL-LHC) require a high bias voltage of 1000 V in order to withstand a radiation damage caused by particle fluences of 1×10{sup 16} 1 MeV n{sub eq}/cm{sup 2} and 1×10{sup 15} 1 MeV n{sub eq}/cm{sup 2} for pixel and strip detectors, respectively. In order to minimize the inactive edge space that can withstand a bias voltage of 1000 V, edge regions susceptible to microdischarge (MD) should be carefully optimized. We fabricated diodes with various edge distances (slim-edge diodes) and with 1–3 multiple guard rings (multi-guard diodes). AC coupling insulators of strip sensors are vulnerable to sudden heavy charge deposition, such as an accidental beam splash, which may destroy the readout AC capacitors. Thus various types of punch-through-protection (PTP) structures were implemented in order to find the most effective structure to protect against heavy charge deposition. These samples were irradiated with 70 MeV protons at fluences of 5×10{sup 12} 1 MeV n{sub eq}/cm{sup 2}–1×10{sup 16} 1 MeV n{sub eq}/cm{sup 2}. Their performances were evaluated before and after irradiation in terms of an onset voltage of the MD, a turn-on voltage of the PTP, and PTP saturation resistance. -- Highlights: ► We have evaluated radiation tolerance of n-in-p sensors up to 1×10{sup 16} 1 MeV n{sub eq}/cm{sup 2}. ► Both n-bulk and p-bulk require a field width≥450 μm in order to withstand 1000 V. ► The MD onset voltage was found to be independent of the edge width. ► With increasing number of guard rings, bias voltage tolerance improved before irrad. ► BZ4D-5 (with full extension) performs the best among the samples.

  13. Management of Chinese restaurant

    OpenAIRE

    Cui , Longbo

    2009-01-01

    With Chinese economy developing rapidly, the Chinese restaurant is under the spotlight, but the management of Chinese restaurant is weak at the moment, especially on the service management, which is an important part of service management in the Chinese restaurant. On the other hand, the managers of Chinese restaurant should pay more attention on the service management for instance brand, service innovation. Service management is core and essential concept for every service company recently, ...

  14. Ingestible wireless capsules for enhanced diagnostic inspection of gastrointestinal tract

    Science.gov (United States)

    Rasouli, Mahdi; Kencana, Andy Prima; Huynh, Van An; Ting, Eng Kiat; Lai, Joshua Chong Yue; Wong, Kai Juan; Tan, Su Lim; Phee, Soo Jay

    2011-03-01

    Wireless capsule endoscopy has become a common procedure for diagnostic inspection of gastrointestinal tract. This method offers a less-invasive alternative to traditional endoscopy by eliminating uncomfortable procedures of the traditional endoscopy. Moreover, it provides the opportunity for exploring inaccessible areas of the small intestine. Current capsule endoscopes, however, move by peristalsis and are not capable of detailed and on-demand inspection of desired locations. Here, we propose and develop two wireless endoscopes with maneuverable vision systems to enhance diagnosis of gastrointestinal disorders. The vision systems in these capsules are equipped with mechanical actuators to adjust the position of the camera. This may help to cover larger areas of the digestive tract and investigate desired locations. The preliminary experimental results showed that the developed platform could successfully communicate with the external control unit via human body and adjust the position of camera to limited degrees.

  15. Trade study for the disposition of cesium and strontium capsules

    International Nuclear Information System (INIS)

    This trade study analyzes alternatives for the eventual disposal of cesium and strontium capsules currently stored at the Waste Encapsulation and Storage Facility as by-product. However, for purposes of this study, it is assumed that at some time in the future, the capsules will be declared high-level waste and therefore will require disposal at an offsite geologic repository. The study considered numerous alternatives and selected three for detailed analysis: (1) overpack and storage at high-level waste canister storage building, (2) overpack at the high-level waste vitrification facility followed by storage at a high-level waste canister storage building, and (3) blend capsule contents with other high-level waste feed streams and vitrify at the high-level waste vitrification facility

  16. Imaging of High-Z doped, Imploded Capsule Cores

    Science.gov (United States)

    Prisbrey, Shon T.; Edwards, M. John; Suter, Larry J.

    2006-10-01

    The ability to correctly ascertain the shape of imploded fusion capsules is critical to be able to achieve the spherical symmetry needed to maximize the energy yield of proposed fusion experiments for the National Ignition Facility. Implosion of the capsule creates a hot, dense core. The introduction of a high-Z dopant into the gas-filled core of the capsule increases the amount of bremsstrahlung radiation produced in the core and should make the imaging of the imploded core easier. Images of the imploded core can then be analyzed to ascertain the symmetry of the implosion. We calculate that the addition of Ne gas into a deuterium gas core will increase the amount of radiation emission while preserving the surrogacy of the radiation and hydrodynamics in the indirect drive NIF hohlraum in the proposed cryogenic hohlraums. The increased emission will more easily enable measurement of asymmetries and tuning of the implosion.

  17. Capsule performance optimization in the National Ignition Campaign

    International Nuclear Information System (INIS)

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [G. H. Miller et al., Nucl. Fusion 44, 228 (2004)] to substantially increase the probability of ignition by laser-driven hohlraums [J. D. Lindl et al., Phys. Plasmas 11, 339 (2004)]. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the OMEGA facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  18. Capsule performance optimization in the National Ignition Campaigna)

    Science.gov (United States)

    Landen, O. L.; Boehly, T. R.; Bradley, D. K.; Braun, D. G.; Callahan, D. A.; Celliers, P. M.; Collins, G. W.; Dewald, E. L.; Divol, L.; Glenzer, S. H.; Hamza, A.; Hicks, D. G.; Hoffman, N.; Izumi, N.; Jones, O. S.; Kirkwood, R. K.; Kyrala, G. A.; Michel, P.; Milovich, J.; Munro, D. H.; Nikroo, A.; Olson, R. E.; Robey, H. F.; Spears, B. K.; Thomas, C. A.; Weber, S. V.; Wilson, D. C.; Marinak, M. M.; Suter, L. J.; Hammel, B. A.; Meyerhofer, D. D.; Atherton, J.; Edwards, J.; Haan, S. W.; Lindl, J. D.; MacGowan, B. J.; Moses, E. I.

    2010-05-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [G. H. Miller et al., Nucl. Fusion 44, 228 (2004)] to substantially increase the probability of ignition by laser-driven hohlraums [J. D. Lindl et al., Phys. Plasmas 11, 339 (2004)]. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the OMEGA facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  19. Capsule performance optimization in the national ignition campaign

    International Nuclear Information System (INIS)

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [1] to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  20. Capsule performance optimization in the national ignition campaign

    Science.gov (United States)

    Landen, O. L.; MacGowan, B. J.; Haan, S. W.; Edwards, J.

    2010-08-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [1] to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  1. Controllable light capsules employing modified Bessel-Gauss beams

    CERN Document Server

    Gong, Lei; Zhao, Qian; Ren, Yuxuan; Qiu, Xingze; Zhong, Mincheng; Li, Yinmei

    2016-01-01

    We report, in theory and experiment, on a novel class of controlled light capsules with nearly perfect darkness, directly employing intrinsic properties of modified Bessel-Gauss beams. These beams are able to naturally create three-dimensional bottle-shaped region during propagation as long as the parameters are properly chosen. Remarkably, the optical bottle can be controlled to demonstrate various geometries through tuning the beam parameters, thereby leading to an adjustable light capsule. We provide a detailed insight into the theoretical origin and characteristics of the light capsule derived from modified Bessel-Gauss beams. Moreover, a binary digital micromirror device (DMD) based scheme is first employed to shape the bottle beams by precise amplitude and phase manipulation. Further, we demonstrate their ability for optical trapping of core-shell magnetic microparticles, which play a particular role in biomedical research, with holographic optical tweezers. Therefore, our observations provide a new rou...

  2. Swallowable Wireless Capsule Endoscopy: Progress and Technical Challenges

    Directory of Open Access Journals (Sweden)

    Guobing Pan

    2012-01-01

    Full Text Available Wireless capsule endoscopy (WCE offers a feasible noninvasive way to detect the whole gastrointestinal (GI tract and revolutionizes the diagnosis technology. However, compared with wired endoscopies, the limited working time, the low frame rate, and the low image resolution limit the wider application. The progress of this new technology is reviewed in this paper, and the evolution tendencies are analyzed to be high image resolution, high frame rate, and long working time. Unfortunately, the power supply of capsule endoscope (CE is the bottleneck. Wireless power transmission (WPT is the promising solution to this problem, but is also the technical challenge. Active CE is another tendency and will be the next geneion of the WCE. Nevertheless, it will not come true shortly, unless the practical locomotion mechanism of the active CE in GI tract is achieved. The locomotion mechanism is the other technical challenge, besides the challenge of WPT. The progress about the WPT and the active capsule technology is reviewed.

  3. Evaluation of hard gelatin capsules and hydroxypropyl methylcellulose containing ampicillin

    Directory of Open Access Journals (Sweden)

    Graziella Gonçalves Weigert

    2012-01-01

    Full Text Available This study aims to develop and evaluate formulations containing ampicillin in capsules of gelatin and hydroxypropyl methylcellulose (HPMC. Two formulations (A and B were developed. The final product quality was evaluated by testing for quality control and the results were in agreement with the Brazilian Pharmacopoeia. The formulations with HPMC capsules showed lower percentages of drug dissolved (99.67%, HPMC-A and 87.70%, HPMC-B than the gelatin (100.18%, GEL-A and 101.16% GEL-B. Because of the delay of the ampicillin release observed in the dissolution profiles, it becomes necessary to evaluate the drugs that can be conditioned in the HPMC capsules.

  4. Inhibitive Effects of Quercetin on Rabbit Tenon Capsule Fibroblasts Proliferation

    Institute of Scientific and Technical Information of China (English)

    Su Liu; Lin Chen

    2005-01-01

    Purpose:To study the inhibitive effects of quercetin (QU) on the fibroblasts proliferation of rabbit Tenon's capsule and its mechanism.Methods: Cultured fibroblasts were exposed to different concentrations of QU solution and investigated by microculture tetrazolium (MTT) assay. The effect of QU was obser ved on cells cycle using the flow cytometer. Besults: QU can suppress the proliferation of rabbit Tenon's capsule fibroblasts in vitro and show a dose-time dependent tendency.Flow cytometer results showed 26.92% cell increase in G1 phase, 23.50% decrease in S phase and 3.42% decrease in G2 phase.Conclusions: QU can suppress the proliferation of rabbit Tenon's capsule fibroblasts in vitro and show a dose-time dependent tendency. QU may effect all phase of cell cycle and inhibit cell proliferation by inhibiting G1 phase transitting to S phase and G2 phase.

  5. Capsule Performance Optimization in the National Ignition Campaign

    Energy Technology Data Exchange (ETDEWEB)

    Landen, O L; MacGowan, B J; Haan, S W; Edwards, J

    2009-10-13

    A capsule performance optimization campaign will be conducted at the National Ignition Facility to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  6. Capsule Performance Optimization for the National Ignition Facility

    Science.gov (United States)

    Landen, Otto

    2009-11-01

    The overall goal of the capsule performance optimization campaign is to maximize the probability of ignition by experimentally correcting for likely residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. This will be accomplished using a variety of targets that will set key laser, hohlraum and capsule parameters to maximize ignition capsule implosion velocity, while minimizing fuel adiabat, core shape asymmetry and ablator-fuel mix. The targets include high Z re-emission spheres setting foot symmetry through foot cone power balance [1], liquid Deuterium-filled ``keyhole'' targets setting shock speed and timing through the laser power profile [2], symmetry capsules setting peak cone power balance and hohlraum length [3], and streaked x-ray backlit imploding capsules setting ablator thickness [4]. We will show how results from successful tuning technique demonstration shots performed at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design meet the required sensitivity and accuracy. We will also present estimates of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors, and show that these get reduced after a number of shots and iterations to meet an acceptable level of residual uncertainty. Finally, we will present results from upcoming tuning technique validation shots performed at NIF at near full-scale. Prepared by LLNL under Contract DE-AC52-07NA27344. [4pt] [1] E. Dewald, et. al. Rev. Sci. Instrum. 79 (2008) 10E903. [0pt] [2] T.R. Boehly, et. al., Phys. Plasmas 16 (2009) 056302. [0pt] [3] G. Kyrala, et. al., BAPS 53 (2008) 247. [0pt] [4] D. Hicks, et. al., BAPS 53 (2008) 2.

  7. Enzymes in the dissolution testing of gelatin capsules.

    Science.gov (United States)

    Marques, Margareth R C

    2014-12-01

    Gelatin capsules are a widely used dosage form both for pharmaceutical drug products as well as dietary supplements. Gelatin in the presence of certain compounds, mainly aldehydes, or in high humidity and high temperature conditions can cross-link. Cross-linking involves covalent bonding of the amine group of a lysine side chain of one gelatin molecule to a similar amine group on another molecule. The covalent bonding is, for practical purposes, irreversible. Cross-linking results in the formation of a pellicle on the internal or external surface of the gelatin capsule shell that prevents the capsule fill from being released. In vitro dissolution testing of cross-linked gelatin capsules can result in slower release of the drug or no release at all. The data obtained by the Gelatin Capsule Working Group, created in the early 90s to investigate noncompliance of gelatin capsules, was used to establish the type and amounts of enzymes that can be added to the dissolution medium in the case of test failure to the presence of cross-linking in the gelatin. The two-tier dissolution testing was included in the US Pharmacopeia and it recommends the addition of pepsin (pH below 6.8) or pancreatin (pH above 6.8) to the medium depending on its pH. Pepsin shows good protease activity up to pH 4 and pancreatin above pH 6 leaving a gap where neither one has good activity. Possible proteolytic enzymes that could be used for the pH range 4-6.8 could be papain or bromelain. PMID:24942315

  8. An O antigen capsule modulates bacterial pathogenesis in Shigella sonnei.

    Directory of Open Access Journals (Sweden)

    Mariaelena Caboni

    2015-03-01

    Full Text Available Shigella is the leading cause for dysentery worldwide. Together with several virulence factors employed for invasion, the presence and length of the O antigen (OAg of the lipopolysaccharide (LPS plays a key role in pathogenesis. S. flexneri 2a has a bimodal OAg chain length distribution regulated in a growth-dependent manner, whereas S. sonnei LPS comprises a monomodal OAg. Here we reveal that S. sonnei, but not S. flexneri 2a, possesses a high molecular weight, immunogenic group 4 capsule, characterized by structural similarity to LPS OAg. We found that a galU mutant of S. sonnei, that is unable to produce a complete LPS with OAg attached, can still assemble OAg material on the cell surface, but a galU mutant of S. flexneri 2a cannot. High molecular weight material not linked to the LPS was purified from S. sonnei and confirmed by NMR to contain the specific sugars of the S. sonnei OAg. Deletion of genes homologous to the group 4 capsule synthesis cluster, previously described in Escherichia coli, abolished the generation of the high molecular weight OAg material. This OAg capsule strongly affects the virulence of S. sonnei. Uncapsulated knockout bacteria were highly invasive in vitro and strongly inflammatory in the rabbit intestine. But, the lack of capsule reduced the ability of S. sonnei to resist complement-mediated killing and to spread from the gut to peripheral organs. In contrast, overexpression of the capsule decreased invasiveness in vitro and inflammation in vivo compared to the wild type. In conclusion, the data indicate that in S. sonnei expression of the capsule modulates bacterial pathogenesis resulting in balanced capabilities to invade and persist in the host environment.

  9. Characterization of the Kingella kingae polysaccharide capsule and exopolysaccharide.

    Directory of Open Access Journals (Sweden)

    Kimberly F Starr

    Full Text Available Recent evidence indicates that Kingella kingae produces a polysaccharide capsule. In an effort to determine the composition and structure of this polysaccharide capsule, in the current study we purified capsular material from the surface of K. kingae strain 269-492 variant KK01 using acidic conditions to release the capsule and a series of steps to remove DNA, RNA, and protein. Analysis of the resulting material by gas chromatography and mass spectrometry revealed N-acetyl galactosamine (GalNAc, 3-deoxy-D-manno-oct-2-ulosonic acid (Kdo, and galactose (Gal. Further analysis by NMR demonstrated two distinct polysaccharides, one consisting of GalNAc and Kdo with the structure →3-β-GalpNAc-(1→5-β-Kdop-(2→ and the other containing galactose alone with the structure →5-β-Galf-(1→. Disruption of the ctrA gene required for surface localization of the K. kingae polysaccharide capsule resulted in elimination of GalNAc and Kdo but had no effect on the presence of Gal in bacterial surface extracts. In contrast, deletion of the pamABCDE locus involved in production of a reported galactan exopolysaccharide eliminated Gal but had no effect on the presence of GalNAc and Kdo in surface extracts. Disruption of ctrA and deletion of pamABCDE resulted in a loss of all carbohydrates in surface extracts. These results establish that K. kingae strain KK01 produces a polysaccharide capsule with the structure →3-β-GalpNAc-(1→5-β-Kdop-(2→ and a separate exopolysaccharide with the structure →5-β-Galf-(1→. The polysaccharide capsule and the exopolysaccharide require distinct genetic loci for surface localization.

  10. Effect of small bowel preparation with simethicone on capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    You-hong FANG; Chun-xiao CHEN; Bing-ling ZHANG

    2009-01-01

    Background: Capsule endoscopy is a novel non-invasive method for visualization of the entire small bowel. The diagnostic yield of capsule endoscopy depends on the quality of visualization of the small bowel mucosa and its complete passage through the small bowel. To date, there is no standardized protocol for bowel preparation before capsule endoscopy. The addition ofsimethicone in the bowel preparation for the purpose of reducing air bubbles in the intestinal lumen had only been studied by a few investigators. Methods: Sixty-four participants were randomly divided into two groups to receive a bowel preparation of polyethylene glycol (PEG) solution (Group 1) and both PEG solution and simethicone (Group 2). The PEG solution and sime-thicone were taken the night before and 20 min prior to capsule endoscopy, respectively. Frames taken in the small intestine were examined and scored for luminal bubbles by two professional capsule endoscopists. Gastric emptying time and small bowel transit time were also recorded. Results: Simethicone significantly reduced luminal bubbles both in the proximal and distal small intes-tines. The mean time proportions with slight bubbles in the proximal and distal intestines in Group 2 were 97.1% and 99.0%, respectively, compared with 67.2% (P<0.001) and 68.8% (P<0.001) in Group 1. Simethicone had no effect on mean gastric emptying time, 32.08 min in Group 2 compared with 30.88 min in Group 1 (P=0.868), but it did increase mean small intestinal transit time from 227.28 to 281.84 min (P=0.003). Conclusion: Bowel preparation with both PEG and simethicone significantly reduced bubbles in the intestinal lumen and improved the visualization of the small bowel by capsule endoscopy without any side effects observed.

  11. First beryllium capsule implosions on the National Ignition Facility

    Science.gov (United States)

    Kline, J. L.; Yi, S. A.; Simakov, A. N.; Olson, R. E.; Wilson, D. C.; Kyrala, G. A.; Perry, T. S.; Batha, S. H.; Zylstra, A. B.; Dewald, E. L.; Tommasini, R.; Ralph, J. E.; Strozzi, D. J.; MacPhee, A. G.; Callahan, D. A.; Hinkel, D. E.; Hurricane, O. A.; Milovich, J. L.; Rygg, J. R.; Khan, S. F.; Haan, S. W.; Celliers, P. M.; Clark, D. S.; Hammel, B. A.; Kozioziemski, B.; Schneider, M. B.; Marinak, M. M.; Rinderknecht, H. G.; Robey, H. F.; Salmonson, J. D.; Patel, P. K.; Ma, T.; Edwards, M. J.; Stadermann, M.; Baxamusa, S.; Alford, C.; Wang, M.; Nikroo, A.; Rice, N.; Hoover, D.; Youngblood, K. P.; Xu, H.; Huang, H.; Sio, H.

    2016-05-01

    The first indirect drive implosion experiments using Beryllium (Be) capsules at the National Ignition Facility confirm the superior ablation properties and elucidate possible Be-ablator issues such as hohlraum filling by ablator material. Since the 1990s, Be has been the preferred Inertial Confinement Fusion (ICF) ablator because of its higher mass ablation rate compared to that of carbon-based ablators. This enables ICF target designs with higher implosion velocities at lower radiation temperatures and improved hydrodynamic stability through greater ablative stabilization. Recent experiments to demonstrate the viability of Be ablator target designs measured the backscattered laser energy, capsule implosion velocity, core implosion shape from self-emission, and in-flight capsule shape from backlit imaging. The laser backscatter is similar to that from comparable plastic (CH) targets under the same hohlraum conditions. Implosion velocity measurements from backlit streaked radiography show that laser energy coupling to the hohlraum wall is comparable to plastic ablators. The measured implosion shape indicates no significant reduction of laser energy from the inner laser cone beams reaching the hohlraum wall as compared with plastic and high-density carbon ablators. These results indicate that the high mass ablation rate for beryllium capsules does not significantly alter hohlraum energetics. In addition, these data, together with data for low fill-density hohlraum performance, indicate that laser power multipliers, required to reconcile simulations with experimental observations, are likely due to our limited understanding of the hohlraum rather than the capsule physics since similar multipliers are needed for both Be and CH capsules as seen in experiments.

  12. A parametric study on ice formation inside a spherical capsule

    Energy Technology Data Exchange (ETDEWEB)

    Ismail, K.A.R.; Silva, T.M. da [Depto. de Engenharia Termica e de Fluidos - FEM-UNICAMP CP: 6122, CEP 13083-970, SP, Campinas (Brazil); Henriquez, J.R. [Depto. de Engenharia Mecanica - DEMEC, UFPE, CEP 50740-530, PE, Recife (Brazil)

    2003-09-01

    This paper reports the results of a numerical study on the heat transfer during the process of solidification of water inside a spherical capsule. The governing equations of the problem and associated boundary conditions were formulated and solved using a finite difference approach and a moving grid scheme. The model was optimized and the numerical predictions were validated by comparison with experimental results realized by the authors. The model was also used to investigate the effects of the size and material of the shell, initial temperature of the phase change material and the external temperature of the spherical capsule on the solidified mass fraction and the time for the complete solidification. (authors)

  13. Dynamic capsule restructuring by the main pneumococcal autolysin LytA in response to the epithelium.

    Science.gov (United States)

    Kietzman, Colin C; Gao, Geli; Mann, Beth; Myers, Lance; Tuomanen, Elaine I

    2016-01-01

    Bacterial pathogens produce complex carbohydrate capsules to protect against bactericidal immune molecules. Paradoxically, the pneumococcal capsule sensitizes the bacterium to antimicrobial peptides found on epithelial surfaces. Here we show that upon interaction with antimicrobial peptides, encapsulated pneumococci survive by removing capsule from the cell surface within minutes in a process dependent on the suicidal amidase autolysin LytA. In contrast to classical bacterial autolysis, during capsule shedding, LytA promotes bacterial survival and is dispersed circumferentially around the cell. However, both autolysis and capsule shedding depend on the cell wall hydrolytic activity of LytA. Capsule shedding drastically increases invasion of epithelial cells and is the main pathway by which pneumococci reduce surface bound capsule during early acute lung infection of mice. The previously unrecognized role of LytA in removing capsule to combat antimicrobial peptides may explain why nearly all clinical isolates of pneumococci conserve this enzyme despite the lethal selective pressure of antibiotics. PMID:26924467

  14. Chinese Manned Space Utility Project

    Science.gov (United States)

    Gu, Y.

    Since 1992 China has been carrying out a conspicuous manned space mission A utility project has been defined and created during the same period The Utility Project of the Chinese Manned Space Mission involves wide science areas such as earth observation life science micro-gravity fluid physics and material science astronomy space environment etc In the earth observation area it is focused on the changes of global environments and relevant exploration technologies A Middle Revolution Image Spectrometer and a Multi-model Micro-wave Remote Sensor have been developed The detectors for cirrostratus distribution solar constant earth emission budget earth-atmosphere ultra-violet spectrum and flux have been manufactured and tested All of above equipment was engaged in orbital experiments on-board the Shenzhou series spacecrafts Space life science biotechnologies and micro-gravity science were much concerned with the project A series of experiments has been made both in ground laboratories and spacecraft capsules The environmental effect in different biological bodies in space protein crystallization electrical cell-fusion animal cells cultural research on separation by using free-low electrophoresis a liquid drop Marangoni migration experiment under micro-gravity as well as a set of crystal growth and metal processing was successfully operated in space The Gamma-ray burst and high-energy emission from solar flares have been explored A set of particle detectors and a mass spectrometer measured

  15. A simple method for preparing radioactive capsules in colon transit study

    International Nuclear Information System (INIS)

    Colon transit study is currently performed by delivering technetium-99m or indium-111 labelled activated charcoal to the colon in a methacrylate-coated capsule (coated capsule). However, the coating procedure is complicated and methacrylate has not been approved by the Food and Drug Administration. Therefore, a simpler method is needed for the clinical routine use of colon transit study. In this study, we used a commercial empty enteric capsule and a coated capsule for the measurement of colon transit time. We compared the in vitro stability and in vivo scintigraphy of 99mTc-labelled activated charcoal in the coated capsule and the enteric capsule to evaluate the possibility of clinical usage of the enteric capsule for colon transit time study. Activated charcoal powder was mixed with 99mTc-diethylene triamine penta-acetic acid (DTPA) and vaporized to dryness. The dry 99mTc-DTPA activated charcoal was loaded into the coated capsule and the enteric capsule. In vitro stability study was performed by immersing these capsules in a colourless buffer of variable pH which mimicked the conditions in the stomach and the small bowel. Capsule disruption was determined. Colon transit scintigraphy with 99mTc-DTPA charcoal was performed in five normal volunteers using these two capsules. The in vitro stability of these two types of capsule was similar and the colon transit scintigraphy findings were almost identical. Most capsules dissolved in the ascending colon and very few in the terminal ileum. It is concluded that enteric capsule is a suitable alternative to coated capsule for measurement of colon transit. (orig.)

  16. Gravimetric Analysis of Particulate Matter using Air Samplers Housing Internal Filtration Capsules

    OpenAIRE

    O'Connor, Sean; O'Connor, Paula Fey; Feng, H. Amy; Ashley, Kevin

    2014-01-01

    An evaluation was carried out to investigate the suitability of polyvinyl chloride (PVC) internal capsules, housed within air sampling devices, for gravimetric analysis of airborne particles collected in workplaces. Experiments were carried out using blank PVC capsules and PVC capsules spiked with 0,1 – 4 mg of National Institute of Standards and Technology Standard Reference Material® (NIST SRM) 1648 (Urban Particulate Matter) and Arizona Road Dust (Air Cleaner Test Dust). The capsules were ...

  17. Coated capsules for drug targeting to proximal and distal part of human intestine.

    Science.gov (United States)

    Dvorácková, Katerina; Rabisková, Miloslava; Gajdziok, Jan; Vetchý, David; Muselík, Jan; Bernatoniene, Jurga; Bajerová, Martina; Drottnerová, Pavlína

    2010-01-01

    Coated hard capsules are becoming increasingly important for a number of reasons such as administration of new active ingredients, oral vaccination, colon drug delivery or their use in preclinical and clinical trials. The independency of coating composition on capsules filling is the major advantage of this dosage form. In our study, two types of hard capsules (gelatin and hypromellose) were coated by non-aqueous solutions of Eudragit L and S 12.5, respectively, to achieve intestinal and distal ileic drug delivery. Gelatin hard capsules were coated with Eudragit film either directly or using hydroxypropyl cellulose sub-coating prior to the final coating. Hypromellose capsules were coated directly. Coated capsules were evaluated for coating thickness by optical microscope and for dissolution in different pH media. Gelatin capsules do not seem to be suitable for direct coating with Eudragit due to insufficient film adhesion to the smooth capsule surface and a brittleness of formed films. These problems can be solved by hydroxypropyl celullose interlayer application. Hypromellose hard capsules could be directly easily coated with both Eudragit solutions. Dissolution of caffeine from coated capsules showed the potency for enteric delivery in gelatin capsules with interlayer and Eudragit L film in 7.5 and 10.0% concentrations and in hypromellose capsules coated with EudragitL in 5-17.5% coating levels. Gelatine capsules with interlayer and 10% Eudragit S film and hypromellose capsules only with high coating level (20%) provided potential distal ileum targeting of incorporated drug. Eudragit S film sprayed onto hypromellose capsules surface was brittle especially in the junction zone between capsule cap and body. Better plasticity of Eudragit S coating could be probably achieved using a different plasticizer. PMID:20369797

  18. Slim door Gym

    OpenAIRE

    Van Dijk, Martin; Groot, Renate de; Kirschner, Paul A.

    2015-01-01

    In deze interactieve presentatie werd de huidige wetenschappelijke stand van zaken omtrent de associatie tussen lichamelijke activiteit en cognitieve prestaties en schoolprestaties besproken. Daarnaast werden de eerste resultaten van De GOALS Studie, ons eigen onderzoek uitgevoerd onder 440 adolescenten, gepresenteerd.

  19. Super- and sub-Eddington accreting massive black holes: a comparison of slim and thin accretion discs through study of the spectral energy distribution

    Science.gov (United States)

    Castelló-Mor, N.; Netzer, H.; Kaspi, S.

    2016-05-01

    We employ optical and ultraviolet (UV) observations to present spectral energy distributions (SEDs) for two reverberation-mapped samples of super-Eddington and sub-Eddington active galactic nuclei (AGN) with similar luminosity distributions. The samples are fitted with accretion disc (AD) models in order to look for SED differences that depend on the Eddington ratio. The fitting takes into account measured black hole (BH) mass and accretion rates, BH spin and intrinsic reddening of the sources. All objects in both groups can be fitted by thin AD models over the range 0.2-1 μm with reddening as a free parameter. The intrinsic reddening required to fit the data are relatively small, E(B - V) ≤ 0.2 mag, except for one source. Super-Eddington AGN seems to require more reddening. The distribution of E(B - V) is similar to what is observed in larger AGN samples. The best-fitting disc models recover very well the BH mass and accretion for the two groups. However, the SEDs are very different, with super-Eddington sources requiring much more luminous far-UV continuum. The exact amount depends on the possible saturation of the UV radiation in slim discs. In particular, we derive for the super-Eddington sources a typical bolometric correction at 5100 Å of 60-150 compared with a median of ˜20 for the sub-Eddington AGN. The measured torus luminosity relative to λLλ(5100 Å) are similar in both groups. The αOX distribution is similar too. However, we find extremely small torus covering factors for super-Eddington sources, an order of magnitude smaller than those of sub-Eddington AGN. The small differences between the groups regarding the spectral range 0.2-22 μm, and the significant differences related to the part of the SED that we cannot observe may be consistent with some slim disc models. An alternative explanation is that present day slim-disc models overestimate the far-UV luminosity of such objects by a large amount.

  20. Hydrodynamic and kinematic parameters of hydraulic capsule flow

    Czech Academy of Sciences Publication Activity Database

    Berman, V.; Kril, S.; Vlasák, Pavel

    Volume 1. Cranfield : BHR Group Limited, 2002 - (Heywood, N.), s. 233-245 ISBN 1-85598-039-8. [International Conference on Hydrotransport /15./. Banff, Canada (CA), 03.06.2002-05.06.2002] R&D Projects: GA AV ČR IBS2060007 Keywords : hydrodynamics * kinematics * capsule flow Subject RIV: BK - Fluid Dynamics

  1. Are Social Networking Websites Educational? Information Capsule. Volume 0909

    Science.gov (United States)

    Blazer, Christie

    2009-01-01

    More and more school districts across the country are joining social networking sites, such as Facebook and MySpace. This Information Capsule discusses the frequency with which school districts are using social networking sites, how districts are using the sites, and potential drawbacks associated with their use. Issues for districts to consider…

  2. Entry Dispersion Analysis for the Stardust Comet Sample Return Capsule

    Science.gov (United States)

    Desai, Prasun N.; Mitcheltree, Robert A.; Cheatwood, F. Mcneil

    1997-01-01

    Stardust will be the first mission to return samples from beyond the Earth-Moon system. The sample return capsule, which is passively controlled during the fastest Earth entry ever, will land by parachute in Utah. The present study analyzes the entry, descent, and landing of the returning sample capsule. The effects of two aerodynamic instabilities are revealed (one in the high altitude free molecular regime and the other in the transonic/subsonic flow regime). These instabilities could lead to unacceptably large excursions in the angle-of-attack near peak heating and main parachute deployment, respectively. To reduce the excursions resulting from the high altitude instability, the entry spin rate of the capsule is increased. To stabilize the excursions from the transonic/subsonic instability, a drogue chute with deployment triggered by an accelerometer and timer is added prior to main parachute deployment. A Monte Carlo dispersion analysis of the modified entry (from which the impact of off-nominal conditions during the entry is ascertained) shows that the capsule attitude excursions near peak heating and drogue chute deployment are within Stardust program limits. Additionally, the size of the resulting 3-sigma landing ellipse is 83.5 km in downrange by 29.2 km in crossrange, which is within the Utah Test and Training Range boundaries.

  3. Structural characterization of polyelectrolyte multilayer hollow capsules by SEM

    Czech Academy of Sciences Publication Activity Database

    Krzyžánek, Vladislav; Keller, U.; Sporenberg, N.; Schönhoff, M.

    Vol. 2. Regensburg: University of Regensburg, 2013, s. 485-486. [Microscopy Conference 2013. Regensburg (DE), 25.08.2013-30. 08.2013] R&D Projects: GA MŠk EE.2.3.20.0103 Institutional support: RVO:68081731 Keywords : cryo-SEM * quantitative imaging * hollow capsules Subject RIV: BH - Optics, Masers, Lasers

  4. A facile route to synthesize silver nanoparticles in polyelectrolyte capsules.

    Science.gov (United States)

    Anandhakumar, S; Raichur, Ashok M

    2011-06-01

    We are reporting a novel green approach to incorporate silver nanoparticles (NPs) selectively in the polyelectrolyte capsule shell for remote opening of polyelectrolyte capsules. This approach involves in situ reduction of silver nitrate to silver NPs using PEG as a reducing agent (polyol reduction method). These nanostructured capsules were prepared via layer by layer (LbL) assembly of poly(allylamine hydrochloride) (PAH) and dextran sulfate (DS) on silica template followed by the synthesis of silver NPs and subsequently the dissolution of the silica core. The size of silver nanoparticles synthesized was 60±20 nm which increased to 100±20 nm when the concentration of AgNO(3) increased from 25 mM to 50 mM. The incorporated silver NPs induced rupture and deformation of the capsules under laser irradiation. This method has advantages over other conventional methods involving chemical agents that are associated with cytotoxicity in biological applications such as drug delivery and catalysis. PMID:21333503

  5. Video-based measurements for wireless capsule endoscope tracking

    International Nuclear Information System (INIS)

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions. (paper)

  6. Promising Tools for Biological Applications: Nanoparticles and Polyelectrolyte Polymer Capsules

    OpenAIRE

    Munoz, Almudena

    2008-01-01

    In this work, we address two different structures whose sizes are in the nanoscopic and microscopic range, namely nanoparticles and polyelectrolyte polymer capsules respectively. Among a wide variety of their promising applications, some are discussed. Synthesis, characterization and surface modification of semiconductor CdSe/ZnS and metallic Au nanoparticles are presented. Au nanoparticles were synthesized directly in organic sol...

  7. Capsule Production in Bacillus cereus Strains Associated with Severe Pneumonia

    OpenAIRE

    Sue, David; Hoffmaster, Alex R.; Popovic, Tanja; Wilkins, Patricia P.

    2006-01-01

    We identified three encapsulated Bacillus cereus strains, isolated from patients with severe pneumonia, in a collection of B. cereus isolates associated with human illness. We found that the extent of capsule expression was influenced by culturing conditions. Our findings highlight consequent clinical and laboratory diagnostic challenges posed by such isolates.

  8. DRY CAUSTIC PEELING OF CLINGSTONE PEACHES. CAPSULE REPORT

    Science.gov (United States)

    The Capsule Report discusses the modified dry caustic process which uses rapidly rotating rubber discs to mechanically wipe the caustic treated peel from clingstone peaches. This report covers two-seasons of evaluation during which the dry caustic peeling system was operated in p...

  9. 10 CFR 32.21 - Radioactive drug: Manufacture, preparation, or transfer for commercial distribution of capsules...

    Science.gov (United States)

    2010-01-01

    ... for commercial distribution of capsules containing carbon-14 urea each for âin vivoâ diagnostic use..., preparation, or transfer for commercial distribution of capsules containing carbon-14 urea each for “in vivo... commercial distribution capsules containing 37 kBq (1 µCi) carbon-14 urea (allowing for nominal...

  10. 75 FR 76017 - Determination That GLEEVEC (Imatinib Mesylate) Capsules, 50 Milligrams and 100 Milligrams, Were...

    Science.gov (United States)

    2010-12-07

    ... HUMAN SERVICES Food and Drug Administration Determination That GLEEVEC (Imatinib Mesylate) Capsules, 50... determined that GLEEVEC (imatinib mesylate) Capsules, 50 milligrams (mg) and 100 mg, were not withdrawn from... new drug applications (ANDAs) for imatinib mesylate capsules, 50 mg and 100 mg, if all other legal...

  11. Evaluation of the Clinical Efficacy of Qingqiao Capsule (清窍胶囊) in Treating Patients with Secretory Otitis Media

    Institute of Scientific and Technical Information of China (English)

    SUN Yong-dong; CHEN Long-hui; HU Wen-jian; JIANG Yu-liang; CHEN Xiao-lin; ZHANG Shi-bo

    2005-01-01

    Objective: To ooserve the clinical efficacy of Qingqiao Capsule (清窍胶囊, QQC) in treating patients with secretory otitis media (SOM). Methods: A total of 90 patients were randomly assigned into the treated group (n=45 ) and the control group (n =45). Patients in the treated group were administrated with QQC, 5 capsules each time, 3 times a day for totally 10-14 days, and those in the control group were given per os cefaclor capsules 0.5g each time for adult, 3 times a day, or 20mg/(kg· d) for children, for 10-14 days. The therapeutic efficacy of treatment on the patients was observed and compared after treatment and followed up for 3-6 months. Results: (1) The clinical efficacy in the treated group was superior to that in the control group with significant statistical difference ( P<0.01 ); (2) Comparison of the efficacies in patients of three different TCM syndrome types (the external pathogenic wind invasion caused auditory orifice stuffiness type, the Gan-Dan damp-heat steaming up auditory orifice type and the Pi-deficiency dysfunction induced dirty dampness blocking ear type) showed no statistically significant difference(P>0.05); (3) The vanishing rate and time needed of the main symptoms and signs in the treated group were superior to those in the control group on ear muffle, tinnitus, hearing impairment, hydrotypanum, pure tone threshold and abnormal tongue figure, and the difference was statistically significant ( P<0.05 or P<0.01), only those of earache,otopiesis and abnornal pulse figure were insignificantly different between the two groups ( P>0.05). Conclusion: QQC is an effective Chinese composite medicine on patients with SOM, and shows no obvious adverse reaction.

  12. Solution Based Deposition of Polyimide Ablators for NIF Capsules

    Energy Technology Data Exchange (ETDEWEB)

    Cook, R

    2002-07-11

    Between June 1997 and March 2002 Luxel Corporation was contracted to explore the possibility of preparing NIF scale capsules with polyimide ablators using solution-based techniques. This work offered a potential alternative to a vapor deposition approach talking place at LLNL. The motivation for pursuing the solution-based approach was primarily two-fold. First, it was expected that much higher strength capsules (relative to vapor deposition) could be prepared since the solution precursors were known to produce high strength films. Second, in applying the ablator as a fluid it was expected that surface tension effects would lead to very smooth surfaces. These potential advantages were offset by expected difficulties, primary among them that the capsules would need to be levitated in some fashion (for example acoustically) during coating and processing, and that application of the coating uniformly to thicknesses of 150 pm on levitated capsules would be difficult. Because of the expected problems with the coupling of levitation and coating, most of the initial effort was to develop coating and processing techniques on stalk-mounted capsules. The program had some success. Using atomizer spray techniques in which application of {approx}5 {micro}m fluid coatings were alternated with heating to remove solvent resulted in up to 70 {micro}m thick coatings that were reasonably smooth at short wavelengths, and showed only about a 1 {micro}m thickness variation over long wavelengths. More controlled deposition with an inkjet devise was also developed. However difficult technical problems remained, and these problems coupled with the relative success of the vapor deposition approach led to the termination of the solution-based work in 2002. What follows is a compilation of the progress reports submitted by Luxel for this work which spanned a number of separate contracts. The reports are arranged chronologically, the last report in the collection has a modest summary of what

  13. Capsule Development and Utilization for Material Irradiation Tests

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Kang, Y. H.; Cho, M. S. (and others)

    2007-06-15

    The essential technology for an irradiation test of materials and nuclear fuel has been successively developed and utilized to meet the user's requirements in Phase I(July 21, 1997 to March 31, 2000). It enables irradiation tests to be performed for a non-fissile material under a temperature control(300{+-}10 .deg. C) in a He gas environment, and most of the irradiation tests for the internal and external users are able to be conducted effectively. The basic technology was established to irradiate a nuclear fuel, and a creep capsule was also developed to measure the creep property of a material during an irradiation test in HANARO in Phase II(April 1, 2000 to March 31, 2003). The development of a specific purpose capsule, essential technology for a re-irradiation of a nuclear fuel, advanced technology for an irradiation of materials and a nuclear fuel were performed in Phase III(April 1, 2003 to February 28, 2007). Therefore, the technology for an irradiation test was established to support the irradiation of materials and a nuclear fuel which is required for the National Nuclear R and D Programs. In addition, an improvement of the existing capsule design and fabrication technology, and the development of an instrumented capsule for a nuclear fuel and a specific purpose will be able to satisfy the user's requirements. In order to support the irradiation test of materials and a nuclear fuel for developing the next generation nuclear system, it is also necessary to continuously improve the design and fabrication technology of the existing capsule and the irradiation technology.

  14. Clinical Observation of Kaixin Capsule (开心胶囊) in Treating Type 2 Diabetes Mellitus Complicated with Abnormal Lipidemia

    Institute of Scientific and Technical Information of China (English)

    薛军; 陈镜合

    2002-01-01

    Objective: To observe the clinical efficacy of Kaixin Capsule (KXC, 开心胶囊), a Chinese compound preparation, in treating type 2 diabetes mellitus (DM) complicated with abnormal lipidemia. Methods: Seventy-two DM inpatients were medicated on the basis of administering conventional hypoglycemics, and KXC was orally taken. They were compared with those patients only taking hypoglycemics to observe the change of blood lipid before and after treatment. Results: The total cholesterol of KXC combined with hypoglycemics group had their blood lipid lowered by 14% after treatment and triglyceride lowered by 36%, HDL-C raised by 11%, and LDL-C lowered by 24%. Compared with only hypoglycemics treatment, there was significant difference (P<0.01). Conclusion: KXC has good blood lipid regulating effect on DM complicated with abnormal lipidemia.

  15. Happy (Chinese) New Year!

    Science.gov (United States)

    Johnson, Georgia G.

    1979-01-01

    Suggestions are made for a classroom celebration of Chinese New Year, including discussion of the Chinese calendar and customs, a short list of appropriate children's stories, and food ideas, including a recipe for fortune cookies. (SJL)

  16. Application of Herringbone Pattern to a Slim-Type Optical Disk Drive for the Reduction of Warpage and Vibration of the Rotating Disk

    Science.gov (United States)

    Seo, Junho; Choi, Moonho; Kim, Hyung-Gi; Rhim, YoonChul

    2011-09-01

    A herringbone pattern is applied beneath the top cover of a slim-type optical disk drive to suppress the warpage and vibration of a rotating disk since the pattern can modify the pressure generation over the disk by changing its geometric parameters. The effect of the herringbone geometries on the pressure generation is evaluated for various geometric parameters. The flow field and the pressure distribution in the cavity are calculated by using a commercial program with the k-ɛ model for the turbulent computation. To confirm the numerical results, the axial vibrations of the rotating disk as well as the pressure distribution of the air gap between the disk and the top cover are measured at various points. In this study, the application of the herringbone pattern reduces the disk warpage and axial vibration by 34 and 10% at most, respectively.

  17. Development of a Low Temperature Irradiation Capsule for Research Reactor Materials

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Kee Nam; Cho, Man Soon; Lee, Cheol Yong; Yang, Sung Woo; Shin, Yoon Taek; Park, Seng Jae; Kang, Suk Hoon; Kang, Young Hwan; Park, Sang Jun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-07-01

    A new capsule design was prepared and tested at HANARO for a neutron irradiation of core materials of research reactors as a part of the research reactor development project. Irradiation testing of the materials including graphite, beryllium, and zircaloy-4 that are supposed to be used as core materials in research reactors was required for irradiation at up to 8 reactor operation cycles at low temperature (<100 .deg. C). Therefore, three instrumented capsules were designed and fabricated for an evaluation of the neutron irradiation properties of the core materials (Graphite, Be, Zircaloy-4) of research reactors. The capsules were first designed and fabricated to irradiate materials at low temperature (<100 .deg. C) for a long cycle of 8 irradiation cycles at HANARO. Therefore, the safety of the new designed capsule should be fully checked before irradiation testing. Out-pile performance and endurance testing before HANARO irradiation testing was performed using a capsule under a 110% condition of a reactor coolant flow amount. The structural integrity of the capsule was analyzed in terms of a vibration-induced fatigue cracking of a rod tip of the capsule that is suspected to be the most vulnerable part of a capsule. Another two capsules were irradiated at HANARO for 4 cycles, and one capsule was transferred to a hot cell to examine the integrity of the rod tip of the capsule. After confirming the soundness of the 4 cycle-irradiated capsule, the remaining capsule was irradiated at up to 8 cycles at HANARO. Based on the structural integrity analysis of the capsule, an improved capsule design will be suggested for a longer irradiation test at HANARO.

  18. Self-shadowing effects of slim accretion disks in active galactic nuclei: the diverse appearance of the broad-line region

    International Nuclear Information System (INIS)

    Supermassive black holes in active galactic nuclei (AGNs) undergo a wide range of accretion rates, which lead to diversity of appearance. We consider the effects of anisotropic radiation from accretion disks on the broad-line region (BLR) from the Shakura-Sunyaev regime to slim disks with super-Eddington accretion rates. The geometrically thick funnel of the inner region of slim disks produces strong self-shadowing effects that lead to very strong anisotropy of the radiation field. We demonstrate that the degree of anisotropy of the radiation fields grows with increasing accretion rate. As a result of this anisotropy, BLR clouds receive different spectral energy distributions depending on their location relative to the disk, resulting in the diverse observational appearance of the BLR. We show that the self-shadowing of the inner parts of the disk naturally produces two dynamically distinct regions of the BLR, depending on accretion rate. These two regions manifest themselves as kinematically distinct components of the broad Hβ line profile with different line widths and fluxes, which jointly account for the Lorentzian profile generally observed in narrow-line Seyfert 1 galaxies. In the time domain, these two components are expected to reverberate with different time lags with respect to the varying ionizing continuum, depending on the accretion rate and the viewing angle of the observer. The diverse appearance of the BLR due to the anisotropic ionizing energy source can be tested by reverberation mapping of Hβ and other broad emission lines (e.g., Fe II), providing a new tool to diagnose the structure and dynamics of the BLR. Other observational consequences of our model are also explored.

  19. Q-switched ruby laser induced damage of the adult rabbit lens capsule

    International Nuclear Information System (INIS)

    The technique of Q-switched ruby laser induced mechanical destruction of the lens capsule was used to study the reactions of the adult rabbit lens. The defect produced in the anterior lens capsule was larger than the 40-60 μm focus, which was due to rolled-up edges of the capsule. Long-term observations revealed some decrease in size of developing localized opacification and a healing of the defect by outgrowing lens epithelium with the formation of a new capsule. The rupture of the posterior capsule led to a slowly progressive opacification with little intraocular macrophage reaction. (orig.)

  20. In Vitro and In Vivo evaluation of hydroxypropylmethyl cellulose phthalate capsules

    OpenAIRE

    E.O. Cetin; M. Asikoglu; E. Gundogdu; O. Orumlu; L. Kirilmaz

    2011-01-01

    The aim of this study was to develop a novel HPMCP capsule. The HPMCP capsule containing99mTc-DTPA and lactose was evaluated in in vitro and in vivo studies. First of all, the HPMCP capsules were prepared and characterized with lenght and diameter size, brittleness facility, moisture content and microbiological test. In vitro resistance and solubility studies of prepared capsules were tested at pH 1.2 and pH 7.4 buffers. The radiolabeled HPMCP capsules were administrated to fasted volunteers....

  1. Development of irradiation capsule for nuclear research reactor using aromatic polyether (BEK)

    International Nuclear Information System (INIS)

    The nuclear reactor irradiation capsule was developed using a poly(arylen ether nitrile)(BEK) on the bases of the research of BEK by irradiation in the pneumatic tube of JRR-3M. The capsule showed high stability until 150 hours irradiation, which was much longer time compared with the 20 minutes for the capsule made of polyethylene. The radioactivity induced by the reactor irradiation was low as same as polyethylene capsule. This report described the irradiation effects of BEK and the stability of the capsule after nuclear reactor irradiation. (author)

  2. Chinese restaurant syndrome

    Directory of Open Access Journals (Sweden)

    Balachandran C

    1991-01-01

    Full Text Available A 24-year-old Chinese student with history of recurrent attacks of flushing with burning and dryness of face of 4 years duration showed exacerbation of the symptoms after oral provocation with 1 mg of Chinese salt. Patient was treated with 50 mg pyridoxine daily and restriction of the Chinese salt in diet with moderate improvement.

  3. Chinese varkens in Nederland

    OpenAIRE

    Zhang, W.L.; Huiskes, J.H.

    1992-01-01

    In China zijn in totaal 300 miljoen varkens van meer dan 100 rassen. Ze worden voor verschillende soorten productie gebruikt. Sommige Chinese rassen zijn in Frankrijk, Nederland en U.S.A. geomporteerd. De vraag is of Chinese varkens nuttig kunnen zijnvoor de varkensproductie in Nederland en zo ja welke Chinese varkens

  4. Formulation, process development and evaluation of artemether and lumefantrine soft gelatin capsule

    Directory of Open Access Journals (Sweden)

    A Patel

    2012-01-01

    Full Text Available Artemether and Lumefantrine capsules are indicated for the treatment of P. falciparum malaria cases resistant to both chloroquine and sulphadoxine, pyrimethamine combination. Both artemether and lumefantrine act as blood schizontocides. Artemether is a sesquiterpene lactone derived from artemisinin. Artemisinin is a compound derived from the sweet wormwood plant and has been used for centuries in traditional Chinese medicine to treat fever. Lumefantrine is a synthetic aryl-amino alcohol antimalarial (quinine, mefloquine and halofantrine are members of the same group. Artemether is absorbed fairly rapidly with peak plasma concentrations reached about 2 hours after dosing. Absorption of lumefantrine, a highly lipophilic compound, starts after a lag period of up to 2 hours, with peak plasma concentration about 6-8 hours after dosing. In order to overcome this problem, we have observed that when the drug is given in the soft gelatin dosage form, the bioavailability of the drug is increased. Thus, increasing the absorption of the drug and peak plasma concentration is reached earlier then the conventional dosage form.

  5. Study on the Pharmacokinetics Drug-drug Interaction of Danmo Capsules with Prednisone in Rats

    Directory of Open Access Journals (Sweden)

    Xiao Chen

    2013-01-01

    Full Text Available The Danmo Capsule (DMC is a widely used patent Chinese botanic drug, prepared with the extract of Radix salviae miltiorrhizae and Ecliptae prostratae. Drug-drug interaction of DMC and prednisone was investigated in rats via in vivo pharmacokinetic studies. After pretreatment with DMC at daily dosages of 0.432 g kg-1 for 14 consecutive days, there were significant decrease in the peak plasma concentration (Cmax of prednisone (from 174.6±32.9 ng mL-1 to 68.2±35.2 ng mL-1, p0-2.5h of prednisone (from 225.9±55.8 h.ng mL-1 to 128.8±37.5 h.ng mL-1, pmax of prednisolone was significantly increased from 155.9±40.4 ng mL-1 to 333.20±95.8 ng mL-1 (p0-8h of prednisolone was significantly increased from 467.5±35.3 h.ng mL-1 to 757.3±105.4 h.ng mL-1 (p1/2 and Mean Residence Time (MRT of prednisone and prednisolone were detected. In conclusion, the increased Cmax and AUC of prednisolone showed co-administration with DMC significantly increased exposure of prednisolone.

  6. Three-dimensional tracking of sensor capsules mobilised by fluid flow

    International Nuclear Information System (INIS)

    A new technique for simultaneously measuring particle trajectories and temperature in fluids using specially designed light-emitting sensor capsules/particles is reported. The sensor capsules each contain a microcontroller (with integrated temperature sensor), uniquely coloured light emitting diodes (LEDs), a battery, and other components. When inserted into a fluid, the sensor capsules are mobilised by fluid flow. As they emit light they can be readily tracked and their 3D position over time measured, using an externally positioned camera along with a planar mirror in a calibrated set-up. The capsules can also take intra-fluid temperature measurements and transmit encoded data by modulating their LEDs whilst moving. Controlled experiments with a sensor capsule placed on a rotating turntable and unconstrained fluid-driven motion of multiple sensor capsules placed in a mixing tank are reported. The results demonstrate how the pathlines of capsules (and instantaneous velocities) and temperature can be simultaneously measured. (paper)

  7. Chinese Food in America

    OpenAIRE

    Jou, Diana T.

    2011-01-01

    How did Chinese food get to look like this? With more than 41,000 Chinese restaurants in America - 3 times the number of McDonald’s restaurants - Chinese food is one of the most accepted and misunderstood cuisines in the United States. From large cities to small towns, locals can always count on an order of orange chicken in a takeout box, with a few fortune cookies thrown in the bag. But what Americans view as Chinese food is far from a traditional Chinese meal, wh...

  8. Danish-accented Chinese

    DEFF Research Database (Denmark)

    Wang, Lei; Sloos, Marjoleine 莱娜; Zhang, Chun

    In search for a linguistic basis for the education of Chinese as a foreign language CFL in Denmark, we set up a new line of investigation into CFL. This research focuses on the phonetics and phonology of Mandarin Chinese as compared to Danish. Considering the sound systems of both languages, we...... note some differences and similarities. The most remarkable differences are: -Chinese has rhotic sounds (pinyin ch, zh, sh, r) but Danish does not -Chinese has affricates (c z ch zh tɕ j) but Danish does not What Danish shares with Chinese is the contrast between aspirated and plain consonants: pa...

  9. Characterization of Bacterial Polysaccharide Capsules and Detection in the Presence of Deliquescent Water by Atomic Force Microscopy

    OpenAIRE

    Su, Hai-Nan; Chen, Zhi-Hua; Liu, Sheng-Bo; Qiao, Li-Ping; Chen, Xiu-Lan; He, Hai-Lun; Zhao, Xian; Zhou, Bai-Cheng; Zhang, Yu-Zhong

    2012-01-01

    We detected polysaccharide capsules from Zunongwangia profunda SM-A87 with atomic force microscopy (AFM). The molecular organization of the capsules at the single-polysaccharide-chain level was reported. Furthermore, we found that with ScanAsyst mode the polysaccharide capsules could be detected even in the presence of deliquescent water covering the capsule.

  10. Capsule Endoscopy in Inflammatory Bowel Disease: Current Applications.

    Science.gov (United States)

    Singeap, Ana-Maria; Stanciu, Carol; Cojocariu, Camelia; Sfarti, Catalin; Trifan, Anca

    2015-06-01

    Since its introduction to clinical practice in 2001, small-bowel capsule endoscopy (SBCE) has become an important investigation procedure in many small bowel pathologies, including both suspected and known Crohn's disease (CD). SBCE has higher diagnostic yield than other radiologic and endoscopic modalities used in evaluation of patients with suspected CD. In addition, SBCE has proved useful, in a non-invasive and safe manner, as a monitoring method for evaluating the severity and extent of lesions, postoperative recurrence, and mucosal healing in patients with known CD. Monitoring of colonic inflammation in patients with ulcerative colitis (UC) using second-generation of colon capsule endoscopy (CCE-2) has also been reported. Besides its advantages, CE also has several limitations such as the inability to obtain biopsies and lack of therapeutic capabilities, hopefully to be overcome in the near future by advances in modern technologies. PMID:26058935

  11. Development of endplug welding technology for irradiation testing capsule

    International Nuclear Information System (INIS)

    To evaluate the performance of newly developed nuclear fuel, it is necessary to irradiate the fuel at a research reactor and examine the irradiated fuel. For the irradiation test in a reasearch reactor, a fuel assembly which is generally called a capsule should be fabricated, considering the fuel irradiation plan and the characteristics of the reactor to be used. And also the fuel elements containing the developed fuel pellets should be made and assembled into a capsule. In this study, the welding method, welding equipment, welding conditions and parameters were developed to make fuel elements for the irradiation test at the HANARO research reactor. The TIG welding method using automatic orbital tube welding system was adopted and the welding joint design was developed for the fabrication of various kinds of irradiation fuel elements. And the optimal welding conditions and parameters were also established for the endplug welding of Zircaloy-4 cladding tube

  12. Capsule Design for Blue Light Therapy against Helicobacter pylori.

    Science.gov (United States)

    Li, Zhangyong; Ren, Binbin; Tan, Haiyan; Liu, Shengrong; Wang, Wei; Pang, Yu; Lin, Jinzhao; Zeng, Chen

    2016-01-01

    A photo-medical capsule that emits blue light for Helicobacter pylori treatment was described in this paper. The system consists of modules for pH sensing and measuring, light-emitting diode driver circuit, radio communication and microcontroller, and power management. The system can differentiate locations by monitoring the pH values of the gastrointestinal tract, and turn on and off the blue light according to the preset range of pH values. Our experimental tests show that the capsule can operate in the effective light therapy mode for more than 32 minutes and the wireless communication module can reliably transmit the measured pH value to a receiver located outside the body. PMID:26814481

  13. Capsule enteroscopy and radiology of the small intestine

    Energy Technology Data Exchange (ETDEWEB)

    Fork, Frans-Thomas [Malmoe University Hospital, Department of Diagnostic Radiology, Malmoe (Sweden); Aabakken, Lars [Rikshospitalet University Hospital, Department of Gastroenterology, Oslo (Norway)

    2007-12-15

    In a very few years, the video capsule for small bowel enteroscopy has gained widespread clinical acceptance. It is readily ingested, disposable, and allows for a complete, low-invasive endoscopic examination of the entire mucosa of the small bowel. It is a patient-friendly method and a first-line procedure in the difficult evaluation of obscure gastrointestinal bleeding. It has the highest proven figure of diagnostic sensitivity for detecting lesions of the mucosa, irrespective of aetiology. The limitations of capsule endoscopy include difficulty in localising mucosal lesions anatomically and its restricted use in patients with dysphagia, strictures or motor dysfunction. Strictures, transmural and extra-mural lesions in patients with small bowel Crohn's disease are evaluated by MRI- enterography and CT-enterography. (orig.)

  14. Capsule enteroscopy and radiology of the small intestine

    International Nuclear Information System (INIS)

    In a very few years, the video capsule for small bowel enteroscopy has gained widespread clinical acceptance. It is readily ingested, disposable, and allows for a complete, low-invasive endoscopic examination of the entire mucosa of the small bowel. It is a patient-friendly method and a first-line procedure in the difficult evaluation of obscure gastrointestinal bleeding. It has the highest proven figure of diagnostic sensitivity for detecting lesions of the mucosa, irrespective of aetiology. The limitations of capsule endoscopy include difficulty in localising mucosal lesions anatomically and its restricted use in patients with dysphagia, strictures or motor dysfunction. Strictures, transmural and extra-mural lesions in patients with small bowel Crohn's disease are evaluated by MRI- enterography and CT-enterography. (orig.)

  15. The CryoCapsule: Simplifying correlative light to electron microscopy

    OpenAIRE

    Heiligenstein, Xavier; HEILIGENSTEIN, Jérôme; DELEVOYE, Cédric; Hurbain, Ilse; Bardin, Sabine; PERRINE, Paul-Gilloteaux; Sengmanivong, Lucie; Régnier, Gilles; Salamero, Jean; Antony, Claude; Raposo, Graca

    2014-01-01

    Correlating complementary multiple scale images of the same object is a straightforward means to decipher biological processes. Light microscopy and electron microscopy are the most commonly used imaging techniques, yet despite their complementarity, the experimental procedures available to correlate them are technically complex. We designed and manufactured a new device adapted to many biological specimens, the CryoCapsule, that simplifies the multiple sample preparation steps, which at pres...

  16. Adhesive capsulitis and dynamic splinting: a controlled, cohort study

    OpenAIRE

    Willis F Buck; Gaspar Paul D

    2009-01-01

    Abstract Background Adhesive Capsulitis (AC) affects patient of all ages, and stretching protocols are commonly prescribed for this condition. Dynamic splinting has been shown effective in contracture reduction from pathologies including Trismus to plantar fasciitis. The purpose of this study was to examine the efficacy of dynamic splinting on patients with AC. Methods This controlled, cohort study, was conducted at four physical therapy, sports medicine clinics in Texas and California. Sixty...

  17. ACCELERATED STABILITY STUDIES OF A POLYHERBAL PREPARATION (EAZMOVR) CAPSULE

    OpenAIRE

    Chauhan, S K; A. Tyagi; Singh, B.; Agarwal, S.

    1999-01-01

    The stability of Eazmov capsule in accelerated condition ie by exposing it to the temperature at 45°C and 40°C with 75% relative humidity was studied. The samples were periodically anallysed upto six months for their organoleptic characteristics, assay of active plant ingredients and the DPTLC finger printing and their peak area analysis, which were found to be stable/ consistent during the period of study. The change in quantifiable components was within 90% of the initial amount, indicating...

  18. Carbamazepine extended-release capsules in bipolar disorder

    OpenAIRE

    Weisler, Richard H

    2006-01-01

    Carbamazepine (CBZ) has long been a therapeutic option for bipolar disorder. Carbamazepine extended-release capsules (CBZ-ERC) are a recent formulation of CBZ approved by the US Food and Drug Administration in 2004 for the treatment of acute manic and mixed episodes associated with bipolar I disorder. This new formulation was developed to improve dosing convenience and decrease daily fluctuations in serum CBZ concentration, thereby lowering the incidence of adverse events. Two randomized, dou...

  19. Structure of polyelectrolyte hollow capsules by scanning electron microscopy

    Czech Academy of Sciences Publication Activity Database

    Krzyžánek, Vladislav; Keller, U.; Sporenberg, N.; Schönhoff, M.

    Budapest : Akadémiai Kiadó, 2015, s. 211-212. ISBN 978-963-05-9653-4. [MCM 2015. Multinational Congress on Microscopy /12./. Eger (HU), 23.08.2015-28.08.2015] R&D Projects: GA ČR(CZ) GA14-20012S Institutional support: RVO:68081731 Keywords : cryo-SEM * low voltage STEM * quantitative imaging * hollow capsules Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  20. The Usefulness of Capsule Endoscopy for Small Bowel Tumors

    OpenAIRE

    Cheung, Dae Young; Kim, Jin Su; Shim, Ki-Nam; Choi, Myung-Gyu; ,

    2016-01-01

    Video capsule endoscopy (VCE) has expanded the range of endoscopic examination of the small bowel. The clinical application of VCE is mainly for obscure gastrointestinal bleeding (OGIB) and small bowel tumor is one of the clinically significant diagnoses of VCE, often requiring subsequent invasive interventions. Small bowel tumors are detected with a frequency of around 4% with VCE in indications of OGIB, iron deficiency anemia, unexplained abdominal pain, and others. Protruding mass with ble...

  1. Capsule enteroscopy and radiology of the small intestine.

    OpenAIRE

    Fork, Thomas; Aabakken, Lars

    2007-01-01

    In a very few years, the video capsule for small bowel enteroscopy has gained widespread clinical acceptance. It is readily ingested, disposable, and allows for a complete, low-invasive endoscopic examination of the entire mucosa of the small bowel. It is a patient-friendly method and a first-line procedure in the difficult evaluation of obscure gastrointestinal bleeding. It has the highest proven figure of diagnostic sensitivity for detecting lesions of the mucosa, irrespective of aetiology....

  2. Reinforcing effects of caffeine in coffee and capsules.

    OpenAIRE

    Griffiths, R R; Bigelow, G E; Liebson, I A

    1989-01-01

    In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference ...

  3. Inpatient capsule endoscopy leads to frequent incomplete small bowel examinations

    OpenAIRE

    Cemal Yazici; John Losurdo; BROWN, MICHAEL D.; Scott Oosterveen; Robert Rahimi; Ali Keshavarzian; Leila Bozorgnia; Ece Mutlu

    2012-01-01

    AIM: To examine the predictive factors of capsule endoscopy (CE) completion rate (CECR) including the effect of inpatient and outpatient status. METHODS: We identified 355 consecutive patients who completed CE at Rush University Medical Center between March 2003 and October 2005. Subjects for CE had either nothing by mouth or clear liquids for the afternoon and evening of the day before the procedure. CE exams were reviewed by two physicians who were unaware of the study hypotheses. After ret...

  4. The Efficacy and Reliability of Capsulovitrectomy for Posterior Capsule Opacification

    OpenAIRE

    Handan Bardak; Yavuz Bardak

    2015-01-01

    Objectives: To investigate the efficiency and reliability of capsulovitrectomy (CV) for posterior capsule opacification (PCO) following cataract operation. Materials and Methods: In this retrospective study, we included 32 eyes of 30 patients with PCO between January 2009 and June 2013 and could not get effective Nd:YAG laser treatment. Pars plana or limbal CV operations were performed at least 6 months after the cataract operation. Results: In these 30 patients, female/male ra...

  5. Investigation of fMRI activation in the internal capsule

    Directory of Open Access Journals (Sweden)

    Brewer Kimberley D

    2011-06-01

    Full Text Available Abstract Background Functional magnetic resonance imaging (fMRI in white matter has long been considered controversial. Recently, this viewpoint has been challenged by an emerging body of evidence demonstrating white matter activation in the corpus callosum. The current study aimed to determine whether white matter activation could be detected outside of the corpus callosum, in the internal capsule. Data were acquired from a 4 T MRI using a specialized asymmetric spin echo spiral sequence. A motor task was selected to elicit activation in the posterior limb of the internal capsule. Results White matter fMRI activation was examined at the individual and group levels. Analyses revealed that activation was present in the posterior limb of the internal capsule in 80% of participants. These results provide further support for white matter fMRI activation. Conclusions The ability to visualize functionally active tracts has strong implications for the basic scientific study of connectivity and the clinical assessment of white matter disease.

  6. Progress in Heavy Ion Target Capsule and Hohlraum Design

    International Nuclear Information System (INIS)

    Progress in heavy ion target design over the past few years has focused on relaxing the target requirements for the driver and for target fabrication. We have designed a plastic (CH) ablator capsule that is easier to fabricate and fill than the beryllium ablator we previously used. In addition, 2-d Rayleigh-Taylor instability calculations indicate that this capsule can tolerate ablator surface finishes up to ten times rougher than the NIF specification. We have also explored the trade-off between surface roughness and yield as a method for finding the optimum capsule. We have also designed two new hohlraums: a ''hybrid'' target and a large angle, distributed radiator target. The hybrid target allows a beam spot radius of almost 5 mm while giving gain of 55 from 6.7 MJ of beam energy in integrated Lasnex calculations. To achieve the required symmetry with the large beam spot, internal shields were used in the target to control the P2 and P4 asymmetry. The large-angle, distributed radiator target is a variation on the distributed radiator target that allows large beam entrance angles (up to 24 degrees). Integrated calculations have produced 340 MJ from 6.2 MJ of beam energy in a design that is not quite optimal. In addition, we have done a simple scaling to understand the peak ion beam power required to compress fuel for fast ignition using a short pulse laser

  7. Adhesive capsulitis and dynamic splinting: a controlled, cohort study

    Directory of Open Access Journals (Sweden)

    Willis F Buck

    2009-09-01

    Full Text Available Abstract Background Adhesive Capsulitis (AC affects patient of all ages, and stretching protocols are commonly prescribed for this condition. Dynamic splinting has been shown effective in contracture reduction from pathologies including Trismus to plantar fasciitis. The purpose of this study was to examine the efficacy of dynamic splinting on patients with AC. Methods This controlled, cohort study, was conducted at four physical therapy, sports medicine clinics in Texas and California. Sixty-two patients diagnosed with Stage II Adhesive Capsulitis were grouped by intervention. The intervention categories were as follows: Group I (Control; Group II (Physical Therapy exclusively with standardized protocols; Group III; (Shoulder Dynasplint system exclusively; Group IV (Combined treatment with Shoulder Dynasplint and standardized Physical Therapy. The duration of this study was 90 days for all groups, and the main outcome measures were change in active, external rotation. Results Significant difference was found for all treatment groups (p Conclusion The difference for the combined treatment group was attributed to patients' receiving the best PT combined with structured "home therapy" that contributed an additional 90 hours of end-range stretching. This adjunct should be included in the standard of care for adhesive Capsulitis. Trial Registration Trial Number: NCT00873158

  8. Little Joe (LJ1A): Only true Boilerplate capsule

    Science.gov (United States)

    1959-01-01

    The Mercury capsule and escape tower are being lowered onto the Little Joe booster for launch on August 21, 1959. Joseph Shortal described this as follows (vol. 3, p. 33): 'The Little Joe booster was assembled at Wallops on its special launcher in a vertical attitude. It is shown in the [on the left] with the work platform in place. The launcher was located on a special concrete slab in Launching Area 1. The capsule was lowered onto the booster by crane.... After the assembly was completed, the scaffolding was disassembled and the launcher pitched over to its normal launch angle of 80 degrees.... Little Joe had a diameter of 80 inches and an overall length, including the capsule and escape tower of 48 feet. The total weight at launch was about 43,000 pounds. The overall span of the stabilizing fins was 21.3 feet.' 'Although in comparison with the overall Mercury Project, Little Joe was a simple undertaking, the fact that an attempt was made to condense a normal two-year project into a 6-month one with in house labor turned it into a major undertaking for Langley.' - Published in Joseph A. Shortal, History of Wallops Station: Origins and Activities Through 1949, (Wallops Island, VA: National Aeronautics and Space Administration, Wallops Station, nd), Comment Edition.

  9. Controllable light capsules employing modified Bessel-Gauss beams.

    Science.gov (United States)

    Gong, Lei; Liu, Weiwei; Zhao, Qian; Ren, Yuxuan; Qiu, Xingze; Zhong, Mincheng; Li, Yinmei

    2016-01-01

    We report, in theory and experiment, on a novel class of controlled light capsules with nearly perfect darkness, directly employing intrinsic properties of modified Bessel-Gauss beams. These beams are able to naturally create three-dimensional bottle-shaped region during propagation as long as the parameters are properly chosen. Remarkably, the optical bottle can be controlled to demonstrate various geometries through tuning the beam parameters, thereby leading to an adjustable light capsule. We provide a detailed insight into the theoretical origin and characteristics of the light capsule derived from modified Bessel-Gauss beams. Moreover, a binary digital micromirror device (DMD) based scheme is first employed to shape the bottle beams by precise amplitude and phase manipulation. Further, we demonstrate their ability for optical trapping of core-shell magnetic microparticles, which play a particular role in biomedical research, with holographic optical tweezers. Therefore, our observations provide a new route for generating and controlling bottle beams and will widen the potentials for micromanipulation of absorbing particles, aerosols or even individual atoms. PMID:27388558

  10. Inflated Sporopollenin Exine Capsules Obtained from Thin-Walled Pollen

    Science.gov (United States)

    Park, Jae Hyeon; Seo, Jeongeun; Jackman, Joshua A.; Cho, Nam-Joon

    2016-06-01

    Sporopollenin is a physically robust and chemically resilient biopolymer that comprises the outermost layer of pollen walls and is the first line of defense against harsh environmental conditions. The unique physicochemical properties of sporopollenin increasingly motivate the extraction of sporopollenin exine capsules (SECs) from pollen walls as a renewable source of organic microcapsules for encapsulation applications. Despite the wide range of different pollen species with varying sizes and wall thicknesses, faithful extraction of pollen-mimetic SECs has been limited to thick-walled pollen capsules with rigid mechanical properties. There is an unmet need to develop methods for producing SECs from thin-walled pollen capsules which constitute a large fraction of all pollen species and have attractive materials properties such as greater aerosol dispersion. Herein, we report the first successful extraction of inflated SEC microcapsules from a thin-walled pollen species (Zea mays), thereby overcoming traditional challenges with mechanical stability and loss of microstructure. Morphological and compositional characterization of the SECs obtained by the newly developed extraction protocol confirms successful protein removal along with preservation of nanoscale architectural features. Looking forward, there is excellent potential to apply similar strategies across a wide range of unexplored thin-walled pollen species.

  11. Design and fabrication of HFIR-MFE RB* spectrally tailored irradiation capsules

    International Nuclear Information System (INIS)

    Design and fabrication of four High Flux Isotope Reactor-magnetic fusion energy removable beryllium capsules (60, 200, 330, and 400/C) to accommodate magnetic fusion energy specimens preirradiated in spectrally tailored experiments in the ORR are proceeding satisfactorily. These capsule designs incorporate provisions for removal, examination, and re-encapsulation of the MFE specimens at intermediate exposure levels en route to a target exposure level of 30 displacements per atom (dpa). With the exception of the 600C capsule, where the test specimens will be in direct contact with the reactor cooling water, the specimen temperatures (monitored by 21 thermocouples) will be controlled by varying the thermal conductance of a small gap region between the specimen holder and the containment tube. Hafnium sleeves will be used to tailor the neutron spectrum to closely match the helium production-to-atom displacement ratio (14 appm/dpa) expected in a fusion reactor first wall. Design and preparation of fabrication drawing for the 60 and 3300C capsules and all generic capsule components and support facilities have now been completed. Assembly of the 600C capsule is complete and the 3300C capsule is nearing completion. The irradiation of both capsules will begin when the HFIR returns to full power operation. Design and preparation of fabrication drawings for the 200 and 4000C capsules will be completed in 1988, and operation of these two capsules will follow the first two (60 and 3300C). 5 references, 3 figures, 1 table

  12. Comparison of esophageal capsule endoscopy and esophagogastroduodenoscopy for diagnosis of esophageal varices

    Institute of Scientific and Technical Information of China (English)

    Catherine T Frenette; John G Kuldau; Donald J Hillebrand; Jill Lane; Paul J Pockros

    2008-01-01

    AIM: To investigate the utility of esophageal capsule endoscopy in the diagnosis and grading of esophageal varices.METHODS: Cirrhotic patients who were undergo-ing esophagogastroduodenoscopy (EGD) for variceal screening or surveillance underwent capsule endos-copy. Two separate blinded investigators read each capsule endoscopy for the following results: variceal grade, need for treatment with variceal banding or prophylaxis with beta-blocker therapy, degree of portal hypertensive gastropathy, and gastric varices.RESULTS: Fifty patients underwent both capsule and EGD. Forty-eight patients had both procedures on the same day, and 2 patients had capsule endoscopy within 72 h of EGD. The accuracy of capsule endos-copy to decide on the need for prophylaxis was 74%,with sensitivity of 63% and specificity of 82%. Inter-rater agreement was moderate (kappa = 0.56). Agree-ment between EGD and capsule endoscopy on grade of varices was 0.53 (moderate). Inter-rater reliability was good (kappa = 0.77). In diagnosis of portal hyper.tensive gastropathy, accuracy was 57%, with sensitiv-ity of 96% and specificity of 17%. Two patients had gastric varices seen on EGD, one of which was seen on capsule endoscopy. There were no complications from capsule endoscopy.CONCLUSION: We conclude that capsule endoscopy has a limited role in deciding which patients would benefit from EGD with banding or beta-blocker thera-py. More data is needed to assess accuracy for staging esophageal varices, PHG, and the detection of gastric varices.

  13. Low-Temperature and Long-Term Irradiation Testing of HANARO Instrumented Capsule

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Kee Nam; Cho, Man Soon; Lee, Cheol Yong; Yang, Sung Woo; Shin, Yoontaek; Park, Sengjae; Kang, Young Hwan; Park, Sang Jun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    In this paper, the low-temperature and long-term irradiation capsule technology developed for the irradiation testing of research reactor materials at HANARO are described. A new capsule and capsule system for long-term irradiation at low temperature was designed, fabricated, and irradiated for an evaluation of the neutron irradiation properties of the core materials (Graphite, Be, Zircaloy-4) of a research reactor for the National Project of 'Research Reactor Development'. Two capsules were first designed and fabricated to irradiate materials at low temperature (36-56 .deg .C) for a long cycle of 8 irradiation cycles at HANARO. The safety of the new irradiation capsule and capsule system was thoroughly evaluated through the out-pile and in-pile testing. The new capsule was successfully irradiated for up to 8 cycles at HANARO. HANARO instrumented irradiation capsules have been actively used for the irradiation of nuclear fuels and materials. Capsule technology was basically developed for irradiation testing under a commercial reactor operation environment. Most irradiation testing using capsules has been performed at specimen temperatures of 250-500 .deg. C within 4 reactor operation cycles (about 100 days) at HANARO. Recently, as a part of the research reactor development's project, irradiation testing of materials used as reflector materials in a research reactor such as graphite, beryllium, and zircaloy-4 was required up to 8 reactor operation cycles at low temperature (<100 .deg. C) of specimens.

  14. Comparative performance of capsulated Vs non-capsulated 14C-urea breath test for the detection of Helicobacter pylori infection

    International Nuclear Information System (INIS)

    Conventionally, 14C-urea breath test (14C-UBT) is employed as a 'gold standard' technique for the detection of active Helicobacter pylori (H pylori) infection, to follow up the patients after its eradication and for epidemiological evaluations. Due to high accuracy of this test and other benefits it is recommended as the best option for 'test-and-treat' strategy in primary health care centers. So far no appropriate study has been done to compare the performance of 14C-UBT using capsulated versus non-capsulated protocol. In this study, we employed a novel technique of performing capsulated 14C-UBT with simultaneous monitoring the dynamic movement of capsule and compared the results with non-capsulated protocol. (author)

  15. Inpatient capsule endoscopy leads to frequent incomplete small bowel examinations

    Institute of Scientific and Technical Information of China (English)

    Cemal Yazici; John Losurdo; Michael D Brown; Scott Oosterveen; Robert Rahimi; Ali Keshavarzian; Leila Bozorgnia

    2012-01-01

    AIM:To examine the predictive factors of capsule endoscopy (CE) completion rate (CECR) including the effect of inpatient and outpatient status.METHODS:We identified 355 consecutive patients who completed CE at Rush University Medical Center between March 2003 and October 2005.Subjects for CE had either nothing by mouth or clear liquids for the afternoon and evening of the day before the procedure.CE exams were reviewed by two physicians who were unaware of the study hypotheses.After retrospective analysis,21 cases were excluded due to capsule malfunction,prior gastric surgery,endoscopic capsule placement or insufficient data.Of the remaining 334 exams [264 out-patient (OP),70 in-patient (IP)],CE indications,findings,location of the patients [IP vs OP and intensive care unit (ICU) vs general medical floor (GMF)] and gastrointestinal transit times were analyzed.Statistical analysis was completed using SPSS version 17 (Chicago,IL).Chi-square,t test or fisher exact-tests were used as appropriate.Multivariate logistic regression analysis was used to identify variables associated with incomplete CE exams.RESULTS:The mean age for the entire study population was 54.7 years.Sixty-one percent of the study population was female,and gender was not different between IPs vs OPs (P =0.07).The overall incomplete CECR was 14% in our study.Overt obscure gastrointestinal bleeding (OGB) was significantly more common for the IP CE (P =0.0001),while abdominal pain and assessment of IBD were more frequent indications for the OP CE exams (P =0.002 and P =0.01,respectively).Occult OGB was the most common indication and arteriovenous malformations were the most common finding both in the IPs and OPs.The capsule did not enter the small bowel (SB) in 6/70 IPs and 8/264OPs (P =0.04).The capsule never reached the cecum in 31.4% (22/70) of IP vs 9.5% (25/ 264) of OP examinations (P < 0.001).The mean gastric transit time (GTT) was delayed in IPs compared to OPs,98.5 ±139.5 min vs 60.4

  16. Effect of Chinese Herbal Fumigation Combined with Tuina on Vertigo and Concentrations of Endothelin and Calcitonin Gene-related Peptide in Patients with Vertebral Artery Cervical Spondylosis

    Institute of Scientific and Technical Information of China (English)

    Zhao Cheng-fei; Liu Xiao-an; Ding Yun

    2014-01-01

    Objective:To observe the effect of Chinese herbal fumigation combined with three-step tuina manipulation on concentration of endothelin (ET) and calcitonin gene-related peptide (CGRP) and vertigo in patients with vertebral artery cervical spondylosis (VACS). Methods:A total of 120 eligible cases were randomly allocated into an observation group and a control group, 60 in each group. Cases in the observation group were treated with Chinese herbal fumigation combined with three-step tuina manipulation, whereas cases in the control group were treated with oral Flunarizine Hydrochloride Capsules. Results: After treatment, vertigo in both groups was alleviated; there were intra-group significant differences in ET decrease and CGRP increase (P Conclusion: Chinese herbal fumigation combined with three-step tuina manipulation can regulate the levels of ET and CGRP and improve vertigo in patients with VACS. Its therapeutic efficacy is superior to oral Flunarizine Hydrochloride Capsules.

  17. Effects of Toutongning capsule on enkephalin expression in a rat migraine headache model

    Institute of Scientific and Technical Information of China (English)

    Gang Yao; Yuhong Man; Jingjing Qi; Tingmin Yu; Dihui Ma

    2011-01-01

    Toutongning capsule is used for the treatment of migraine headaches, and has yielded therapeutically beneficial effects. However, whether Toutongning capsule exerts its effects via endogenous opioid peptides remains poorly understood. This study investigated the effects of Toutongning capsule on enkephalin expression in the midbrain of rats with nitroglycerin-induced migraine headache at the mRNA and protein levels. Results confirmed that proenkephalin mRNA levels were significantly upregulated following treatment with Toutongning capsule. The numbers of methionine-enkephalin and leucine-enkephalin-positive cells were significantly greater in the migraine headache rats following treatment with Toutongning capsule compared with the model group. Taken together, these results show that Toutongning capsule exerts potentially beneficial effects by promoting enkephalin expression in nitroglycerin-induced migraine headache rats.

  18. Characterization of two WESF [Waste Encapsulation and Storage Facility] capsules after five years of service

    International Nuclear Information System (INIS)

    Two Waste Encapsulation and Storage Facility (WESF) 137Cs capsules have been analyzed destructively after five years of service in the Sandia Irradiator for Dried Sewage Solids (SIDSS). The program concentrated on studies of the inner capsule, inner capsule weld areas, and analysis of the CsCl salt. No measurable corrosion was observed on the capsule wall or welds after the five years in the SIDSS Facility. The operating temperatures of the inner capsule wall were calculated to be between 140 and 180/degree/C. Radiochemistry and isotopic analyses provided data for specific activity calculations. There was good correlation between the measured calorimetry of the capsules before sectioning, 53 and 55 kCi, and the activity calculations, 54 and 59 kCi, respectively. 21 refs., 43 figs., 18 tabs

  19. Temperature distribution analysis of the capsule with multi holes using ANSYS code

    International Nuclear Information System (INIS)

    Specimen holder in a capsule for material irradiation tests has often multi-holes. This type of capsule can be considered as a heat source because every part of the capsule is heated by gamma flux in a research reactor. In this study, specimen temperature in the thermal media during irradiation was first evaluated with a FEM program, ANSYS. The results for 97M-01K capsule were compared with experimental data and numerical data obtained by Heating 7.2f code, respectively. These three evaluation methods showed well coincident results so that the approach with ANSYS program will be applied to evaluate various cases of capsule design, which will be useful in the design and safety analysis of the capsule for material irradiation tests

  20. Shuganjieyu capsule increases neurotrophic factor expression in a rat model of depression

    Institute of Scientific and Technical Information of China (English)

    Jinhua Fu; Yingjin Zhang; Renrong Wu; Yingjun Zheng; Xianghui Zhang; Mei Yang; Jingping Zhao; Yong Liu

    2014-01-01

    Shuganjieyu capsule has been approved for clinical treatment by the State Food and Drug Ad-ministration of China since 2008. In the clinic, Shuganjieyu capsule is often used to treat mild to moderate depression. In the rat model of depression established in this study, Shuganjieyu capsule was administered intragastrically daily before stress. Behavioral results conifrmed that depressive symptoms lessened after treatment with high-dose (150 mg/kg) Shuganjieyu capsule. Immunohistochemistry results showed that high-dose Shuganjieyu capsule signiifcantly increased phosphorylation levels of phosphorylation cyclic adenosine monophosphate response element binding protein and brain-derived neurotrophic factor expression in the medial prefrontal cortex and hippocampal CA3 area. Overall, our results suggest that in rats, Shuganjieyu capsule effec-tively reverses depressive-like behaviors by increasing expression levels of neurotrophic factors in the brain.

  1. DETERMINATION OF THE AGR-1 CAPSULE TO FPMS SPECTROMETER TRANSPORT VOLUMES FROM LEADOUT FLOW TEST DATA

    International Nuclear Information System (INIS)

    The AGR-1 experiment is a fueled multiple-capsule irradiation experiment being conducted in the Advanced Test Reactor (ATR) in support of the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. A flow experiment conducted during the AGR-1 irradiation provided data that included the effect of flow rate changes on the decay of a short-lived radionuclide (23Ne). This data has been analyzed to determine the capsule-specific downstream transport volume through which the capsule effluents must pass before arrival at the fission product monitoring system spectrometers. These resultant transport volumes when coupled with capsule outlet flow rates determine the transport times from capsule-to-detector. In this work an analysis protocol is developed and applied in order to determine capsule-specific transport volumes to precisions of better than +/- 7%

  2. CHINESE OF HUMANITY

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    A discussion of chinese curriculum of primary school under the background of new curriculum reform Mao xinjuan Feng haiying [Abstract] in recent years, Chinese learning received more and more attention by people article mainly from the national studies this course concepts, the curriculum reform of elementary school curriculum requirements and how to effective implementation of primary national studies course several aspects under the background of curriculum reform of Chinese primary curriculum the new school

  3. Improved Water Barrier Properties of Calcium Alginate Capsules Modified by Silicone Oil

    OpenAIRE

    Brian G. Zukas; Nivedita R. Gupta

    2016-01-01

    Calcium alginate films generally offer poor diffusion resistance to water. In this study, we present a technique for encapsulating aqueous drops in a modified calcium alginate membrane made from an emulsion of silicone oil and aqueous alginate solution and explore its effect on the loss of water from the capsule cores. The capsule membrane storage modulus increases as the initial concentration of oil in the emulsion is increased. The water barrier properties of the fabricated capsules were de...

  4. Intra-articular Corticosteroid Injection for the Treatment of Idiopathic Adhesive Capsulitis of the Shoulder

    OpenAIRE

    Marx, Robert G.; Malizia, Robert W.; Kenter, Keith; Wickiewicz, Thomas L.; Hannafin, Jo A.

    2007-01-01

    Treatment for idiopathic adhesive capsulitis or frozen shoulder of the shoulder is controversial. The hypothesis of the study is that intra-articular corticosteroid injection in the early stages of idiopathic adhesive capsulitis will lead to a razpid resolution of stiffness and symptoms. This is a retrospective cohort study of only patients with stage 1 or stage 2 adhesive capsulitis. The diagnosis was made by history and physical examination and only when other causes of pain and motion loss...

  5. THICKENING AND MULTILAMELLAR APPEARANCE OF THE ANTERIOR LENS CAPSULE AND RELATED FACTORS

    OpenAIRE

    Kazuo Tsutsui; Yosmaki Nawa; Sachiko Uemura; Mitsuo Tsukamoto; Toshio Shimizu; Masaya Kominami; Yoshiaki Hara

    2004-01-01

    The purpose of this study was to investigate which factors (including age, sex, grade of cataract, diabetes mellitus (DM), pseudoexfoliation, glaucoma, and atopy) are correlated with thickening and/or multilamellar appearance of the anterior lens capsule. Seventy-two anterior lens capsules were obtained during cataract surgeries. They were fixed, embedded in paraffin, and stained with Periodic acid-Schiff (PAS) and Masson-Trichrome. We measured thickness of the anterior capsules on microscopi...

  6. Capsule endoscopy of the future: What’s on the horizon?

    OpenAIRE

    Slawinski, Piotr R.; Obstein, Keith L.; Valdastri, Pietro

    2015-01-01

    Capsule endoscopes have evolved from passively moving diagnostic devices to actively moving systems with potential therapeutic capability. In this review, we will discuss the state of the art, define the current shortcomings of capsule endoscopy, and address research areas that aim to overcome said shortcomings. Developments in capsule mobility schemes are emphasized in this text, with magnetic actuation being the most promising endeavor. Research groups are working to integrate sensor data a...

  7. Irradiation capsule for testing magnetic fusion reactor first-wall materials at 60 and 2000C

    International Nuclear Information System (INIS)

    A new type of irradiation capsule has been designed, and a prototype has been tested in the Oak Ridge Research Reactor (ORR) for low-temperature irradiation of Magnetic Fusion Reactor first-wall materials. The capsule meets the requirements of the joint US/Japanese collaborative fusion reactor materials irradiation program for the irradiation of first-wall fusion reactor materials at 60 and 2000C. The design description and results of the prototype capsule performance are presented

  8. Work plan for testing silicone impression material and fixture on pool cell capsule

    International Nuclear Information System (INIS)

    The purpose of this work plan is to provide a safe procedure to test a cesium capsule impression fixture at Waste Encapsulation and Storage Facility (WESF). The impression will be taken with silicone dental impression material pressed down upon the capsule using the impression fixture. This test will evaluate the performance of the fixture and impression material under high radiation and temperature conditions on a capsule in a WESF pool cell

  9. Design of polymeric capsules for autonomous healing of cracks in cementitious materials

    OpenAIRE

    HILLOULIN, Benoit; Van Tittelboom, Kim; Gruyaert, Elke; LOUKILI, Ahmed; De Belie, Nele

    2013-01-01

    Now, most of the capsules used to contain polymeric healing agents in self-healing concrete, are made of glass. However, glass capsules cannot be mixed in concrete and are therefore placed manually into the moulds during concrete casting in laboratory tests. This represents a major drawback for an eventual industrialisation. In this study, polymeric capsules were designed to meet three requirements: breakage upon crack appearance, compatibility with the polymeric healing agent and survival...

  10. On the Feasibility of Steering Swallowable Microsystem Capsules Using Computer-Aided Magnetic Levitation

    OpenAIRE

    Wu, Billy; Mintchev, Martin

    2008-01-01

    Swallowable capsule endoscopy is used for non-invasive diagnosis of some gastrointestinal (GI) organs. However, control over the position of the capsule is a major unresolved issue. This study presents a design for steering the capsule based on magnetic levitation. The levitation is stabilized with the aid of a computer-aided feedback control system and diamagnetism. Peristaltic and gravitational forces to be overcome were calculated. A levitation setup was built to analyze the fe...

  11. Arthroscopic Superior Capsule Reconstruction for Irreparable Rotator Cuff Tears

    Science.gov (United States)

    Mihata, Teruhisa; Lee, Thay Q.; Itami, Yasuo; HASEGAWA, Akihiko; Ohue, Mutsumi; Neo, Masashi

    2016-01-01

    Objectives: An arthroscopic superior capsule reconstruction, in which the fascia lata autograft attached medially to the superior glenoid and laterally to the greater tuberosity, restores shoulder stability and muscle balance in patients with irreparable rotator cuff tears; consequently, it improves shoulder function specifically deltoid muscle function and relieves pain. We assessed the clinical outcome of arthroscopic superior capsule reconstruction (Figure 1) in 100 consecutive patients with irreparable rotator cuff tears. Specifically, we focused on the rates of return to sport and work. Methods: From 2007 to 2014, we performed arthroscopic superior capsule reconstruction on 107 consecutive patients (mean 66.7 years; range, 43 to 82) with irreparable rotator cuff tears that had failed conservative treatment. Seven patients were lost to follow-up because of other medical problems or reasons. In the remaining 100 patients there were 56 supraspinatus and infraspinatus tears; 39 supraspinatus, infraspinatus, and subscapularis tears; 3 supraspinatus, infraspinatus, teres minor, and subscapularis tears; and 2 supraspinatus, infraspinatus, and teres minor tears. Physical examination, radiography, and MRI were performed before surgery; at 3, 6, and 12 months after surgery; and yearly thereafter. Rates of return to sport and work were also investigated in those patients who had been employed (34 patients: 21 manual workers, 10 farmers, 1 butcher, 1 cook, and 1 athletic trainer) or played sport (26 patients: 6 golf, 4 table tennis, 4 swimming, 3 martial arts, 2 baseball, 2 yoga, 1 tennis, 1 badminton, 1 skiing, 1 mountain-climbing, and 1 ground golf) before injury. Results: The average preoperative American Shoulder and Elbow Surgeons (ASES) score was 31.6 points (range, 3.3 to 63.3 points) and the average Japanese Orthopaedic Association (JOA) score was 51.6 points (26.5 to 68.5 points). Average postoperative clinical outcome scores all improved significantly at final

  12. Panning of a phage display library against a synthetic capsule for peptide ligands that bind to the native capsule of Bacillus anthracis.

    Directory of Open Access Journals (Sweden)

    Michael Beer

    Full Text Available Bacillus anthracis is the causative agent of anthrax with the ability to not only produce a tripartite toxin, but also an enveloping capsule comprised primarily of γ-D-glutamic acid residues. The purpose of this study was to isolate peptide ligands capable of binding to the native capsule of B. anthracis from a commercial phage display peptide library using a synthetic form of the capsule consisting of 12 γ-D-glutamic acid residues. Following four rounds of selection, 80 clones were selected randomly and analysed by DNA sequencing. Four clones, each containing a unique consensus sequence, were identified by sequence alignment analysis. Phage particles were prepared and their derived 12-mer peptides were also chemically synthesized and conjugated to BSA. Both the phage particles and free peptide-BSA conjugates were evaluated by ELISA for binding to encapsulated cells of B. anthracis as well as a B. anthracis capsule extract. All the phage particles tested except one were able to bind to both the encapsulated cells and the capsule extract. However, the peptide-BSA conjugates could only bind to the encapsulated cells. One of the peptide-BSA conjugates, with the sequence DSSRIPMQWHPQ (termed G1, was fluorescently labelled and its binding to the encapsulated cells was further confirmed by confocal microscopy. The results demonstrated that the synthetic capsule was effective in isolating phage-displayed peptides with binding affinity for the native capsule of B. anthracis.

  13. Capsulation and Gene Copy Number at the cap Locus of Haemophilus influenzae Type b

    OpenAIRE

    1988-01-01

    Although more than 98% of natural isolates of Haemophilus influenzae type b carry a duplication of 17 kilobases (kb) of DNA at the chromosomal capsulation locus, only one copy is required for capsulation. In one laboratory-derived and two clinical type b strains, the capsulation locus had a single copy of this 17-kb segment, together with 1.3 kb of DNA identified as lying between the repeats of the duplicated locus. This 1.3 kb appears to be crucial for capsule production, since strains lacki...

  14. Stress analysis and testing of the outer capsule design for the Strontium Heat Source Development Program

    Energy Technology Data Exchange (ETDEWEB)

    Simonen, F.A.; Shippell, R.J. Jr.; Atteridge, D.G.

    1980-01-01

    The objective of the Strontium Heat Source Development Program is to obtain the data needed to license /sup 90/SrF/sub 2/ heat sources - specifically the /sup 90/SrF/sub 2/ capsules produced in the Waste Encapsulation and Storage Facility (WESF) at Hanford. Toward this end, a high integrity outer capsule has been designed to replace the present outer capsule of the WESF /sup 90/SrF/sub 2/ capsule. The proposed design of a Hastelloy S outer capsule which features a mechanical interlock type of end closure is described. Qualification testing requirements are outlined, and stress analyses and developmental tests are described. These tests were performed on AISI-1018 steel stand-in capsules, and included both external pressure and impact tests. The external pressure tests showed that stress calculations seriously overestimated the pressure capability of the outer capsule. Possible reasons for the lack of agreement between the tests and the analyses are evaluated. The stress analyses and tests results indicate that the proposed outer capsule will meet the heat source qualification requirements. Future tests will be conducted to experimentally verify that the Hastelloy S outer capsule in an aged condition meets the structural integrity requirements.

  15. Stress analysis and testing of the outer capsule design for the Strontium Heat Source Development Program

    International Nuclear Information System (INIS)

    The objective of the Strontium Heat Source Development Program is to obtain the data needed to license 90SrF2 heat sources - specifically the 90SrF2 capsules produced in the Waste Encapsulation and Storage Facility (WESF) at Hanford. Toward this end, a high integrity outer capsule has been designed to replace the present outer capsule of the WESF 90SrF2 capsule. The proposed design of a Hastelloy S outer capsule which features a mechanical interlock type of end closure is described. Qualification testing requirements are outlined, and stress analyses and developmental tests are described. These tests were performed on AISI-1018 steel stand-in capsules, and included both external pressure and impact tests. The external pressure tests showed that stress calculations seriously overestimated the pressure capability of the outer capsule. Possible reasons for the lack of agreement between the tests and the analyses are evaluated. The stress analyses and tests results indicate that the proposed outer capsule will meet the heat source qualification requirements. Future tests will be conducted to experimentally verify that the Hastelloy S outer capsule in an aged condition meets the structural integrity requirements

  16. Endurance test for non-instrumented capsule of advanced PWR fuel pellet (test procedure)

    International Nuclear Information System (INIS)

    This test procedure details the test loop, test method, and test procedure for pressure drop, vibration and endurance test of Non-instrumented Capsule of Advanced PWR Fuel Pellet. From the pressure drop test, the hydraulic design requirements of the capsule are verified. HANARO limit condition is checked and the compatibility with HANARO core is verified. From flow induced vibration test vibration frequency, vibration displacement are investigated. The wear of Non-instrumented Capsule of Advanced PWR Fuel Pellet is investigated through endurance test, and these data are used to evaluate the expected wear of during maximum resident time of Non-instrumented Capsule

  17. Design of leakage test apparatus of FPM capsule in Multi Purpose Reactor G.A. Siwabessy

    International Nuclear Information System (INIS)

    To protect the leakage even of the irradiation FPM capsule before irradiated, some examination which can assured the capsule in good condition is needed. Once of the useful examination method is pressure submerged testing method. In order that the leakage examination by this method can be done, the design of leakage test apparatus of FPM capsule in Centre For Development of Research Reactor Technology has been done. By the design propose, the capsule condition can be assure without leakage and ready to irradiated. By the calculation and analysis performed, the design of Leakage Test apparatus of FPM capsule proposed was capable to resist of the stresses during operation. For realizing the design, of a units of Leakage test apparatus of FPM capsule needs a piece SS 304 pipe sch 40 by 6 inch in diameter, a unit of regulator completed with pressure gage, 3 pieces of SS 304 plate by 300 x 300 x 10 mm in dimension. By the leakage test apparatus of FPM capsule design, irradiation processes of FPM capsule can be done without worrying of capsule leakage ensure

  18. A study for development of a material irradiation capsule in the OR holes of HANARO

    International Nuclear Information System (INIS)

    This paper focuses on the design of a capsule for a material irradiation that is supposed to be loaded in an OR test hole in the HANARO. Through a technical analysis of the HANARO test holes, a new capsule for an irradiation of medium and high temperature materials in an OR test hole was designed and fabricated. A test for a pressure drop and a vibration of this capsule was performed before manufacturing a material capsule suitable for an OR hole in HANARO. The conceptual design of a capsule was performed to design a capsule to irradiate materials at the hole. The capsule is fixed by using a clamp device by pressing a stopper onto the protection tube. It was concluded before the test, that the diameter of a capsule for an OR holes should be more than 49mm by an evaluation of a flow rate and pressure drop in theory. Based on the out-pile test results, an irradiation capsule with a diameter of 56mm was finally fabricated and irradiated successfully in the HANARO

  19. Inductive-Based Wireless Power Recharging System for an Innovative Endoscopic Capsule

    Directory of Open Access Journals (Sweden)

    Giuseppe Tortora

    2015-09-01

    Full Text Available Wireless capsule endoscopic devices are adopted for painless diagnosis of cancer and other diseases affecting the gastrointestinal tract as an alternative to traditional endoscopy. Although much work has been done to improve capsule performance in terms of active navigation, a major drawback is the limited available energy on board the capsule, usually provided by a battery. Another key shortcoming of active capsules is their limitation in terms of active functionalities and related costs. An inductive-based wireless recharging system for the development of an innovative capsule for colonoscopy is proposed in this paper; the aim is to provide fast off-line battery recovery for improving capsule lifecycle and thus reducing the cost of a single endoscopic procedure. The wireless recharging system has been properly designed to fit the dimensions of a capsule for colonoscopy but it can be applied to any biomedical devices to increase the number of times it can be used after proper sterilization. The current system is able to provide about 1 W power and is able to recharge the battery capsule in 20 min which is a reasonable time considering capsule operation time (10–15 min.

  20. Current and future role of magnetically assisted gastric capsule endoscopy in the upper gastrointestinal tract.

    Science.gov (United States)

    Ching, Hey-Long; Hale, Melissa Fay; McAlindon, Mark Edward

    2016-05-01

    Capsule endoscopy first captivated the medical world when it provided a means to visualize the small bowel, which was previously out of endoscopic reach. In the subsequent decade and a half we continue to learn of the true potential that capsule endoscopy has to offer. Of particular current interest is whether capsule endoscopy has any reliable investigative role in the upper gastrointestinal tract. Much research has already been dedicated to enhancing the diagnostic and indeed therapeutic properties of capsule endoscopy. Specific modifications to tackle the challenges of the gut have already been described in the current literature. In the upper gastrointestinal tract, the capacious anatomy of the stomach represents one of many challenges that capsule endoscopy must overcome. One solution to improving diagnostic yield is to utilize external magnetic steering of a magnetically receptive capsule endoscope. Notionally this would provide a navigation system to direct the capsule to different areas of the stomach and allow complete gastric mucosal examination. To date, several studies have presented promising data to support the feasibility of this endeavour. However the jury is still out as to whether this system will surpass conventional gastroscopy, which remains the gold standard diagnostic tool in the foregut. Nevertheless, a minimally invasive and patient-friendly alternative to gastroscopy remains irresistibly appealing, warranting further studies to test the potential of magnetically assisted capsule endoscopy. In this article the authors would like to share the current state of magnetically assisted capsule endoscopy and anticipate what is yet to come. PMID:27134661

  1. 3D numerical simulations of vesicle and inextensible capsule dynamics

    Science.gov (United States)

    Farutin, Alexander; Biben, Thierry; Misbah, Chaouqi

    2014-10-01

    Vesicles are locally-inextensible fluid membranes, capsules are endowed with in-plane shear elasticity mimicking the cytoskeleton of red blood cells (RBCs), but are extensible, while RBCs are inextensible. We use boundary integral (BI) methods based on the Green function techniques to model and solve numerically their dynamics. We regularize the single layer integral by subtraction of exact identities for the terms involving the normal and the tangential components of the force. The stability and precision of BI calculation is enhanced by taking advantage of additional quadrature nodes located in vertices of an auxiliary mesh, constructed by a standard refinement procedure from the main mesh. We extend the partition of unity technique to boundary integral calculation on triangular meshes. The proposed algorithm offers the same treatment of near-singular integration regardless whether the source and the target points belong to the same surface or not. Bending forces are calculated by using expressions derived from differential geometry. Membrane incompressibility is handled by using two penalization parameters per suspended entity: one for deviation of the global area from prescribed value and another for the sum of squares of local strains defined on each vertex. Extensible or inextensible capsules, a model of RBC, are studied by storing the position in the reference configuration for each vertex. The elastic force is then calculated by direct variation of the elastic energy. Various nonequilibrium physical examples on vesicles and capsules will be presented and the convergence and precision tests highlighted. Overall, a good convergence is observed with numerical error inversely proportional to the number of vertices used for surface discretization, the highest order of convergence allowed by piece-wise linear interpolation of the surface.

  2. Pharmacokinetics of budesonide (Entocort EC) capsules for Crohn's disease.

    Science.gov (United States)

    Edsbäcker, Staffan; Andersson, Tommy

    2004-01-01

    This overview summarises available pharmacokinetic data on budesonide capsules (Entocort EC), approved for the treatment of mild-to-moderate active Crohn's disease involving the ileum and/or ascending colon and for prolongation of symptom control. Budesonide is a locally-acting glucocorticosteroid with an extensive, primarily hepatic, metabolism after oral administration. It is rapidly absorbed and biotransformed by cytochrome P450 (CYP) 3A to metabolites with negligible glucocorticoid activity. Entocort EC, a pH- and time-dependent oral formulation of budesonide, was developed to optimise drug delivery to the ileum and throughout the colon. Pharmaco-scintigraphic studies have confirmed that the Entocort EC formulation delays budesonide absorption and prolongs the rate of elimination but maintains complete absorption. This improves the delivery of budesonide to the intestinal lumen relative to a plain formulation. A low systemic availability of 9-21% indicates extensive first-pass elimination. Food appears to have little impact on the absorption of budesonide from Entocort EC capsules and the pharmacokinetics are dose-proportional between 3 and 15 mg. On average, systemic availability was 2.5-fold higher in patients with cirrhosis compared with healthy controls; however, mild liver impairment had little effect on systemic exposure. Pharmacokinetics appear unaffected by gender and age, although this has not been tested in younger children. Renal impairment is not expected to have an impact on the kinetics of Entocort EC. Budesonide is unlikely to inhibit the metabolism of other drugs, including CYP3A4 substrates, mainly because of the very low plasma concentrations obtained with the compound even after high doses of Entocort trade mark EC capsules. Strong CYP3A4 inhibitors, such as ketoconazole, will inhibit the metabolism of budesonide, resulting in several-fold increases in the area under the concentration-time curve of budesonide. Also, grapefruit juice intake

  3. Measurement of capsule heat transfer gaps using neutron radiography

    Science.gov (United States)

    Thaler, L. A.

    1974-01-01

    A technique is described for measuring heat transfer gaps from neutron radiographs. The method involves scanning the radiograph negative with a recording microdensitometer to obtain a trace of the optical density variation across the diameter of the capsule. The optical density change representing the gap is measured from the microdensitometer trace and related to the physical measurement. Heat transfer gaps from 0.061 to 0.178 cm have been determined by this technique and agree with preassembly physical measurements to plus or minus 0.005 cm.

  4. Treatment of rheumatoid arthritis by Xinfeng capsule: an efficacy observation

    Institute of Scientific and Technical Information of China (English)

    黄传兵

    2014-01-01

    Objective To observe the curative effect of Xinfeng Capsule(XC)in treatment of rheumatoid arthritis(RA).Methods Recruited were 80 active RA patients,who were randomly assigned to the normal control group and the treatment group,40 in each group.All patients received the same routine anti-rheumatic treatment:Methotrexate 10 mg per week;Diclofenac 50 mg when painwas obvious,twice daily.Patients in the treatment group took XC 3 tablets each time,thrice daily.All treatment lasted for 12

  5. Spectrophotometric Determination of Mexiletine Hydrochloride in Capsules Using Bromothymol Blue

    OpenAIRE

    Aydoğmuş, Zeynep; ÇETİN, S. Müge; Tosunoğlu, Sedat

    2002-01-01

    A new spectrophotometric method based on the formation of an ion-pair using bromothymol blue as ion-pair complexing reagent was developed for the determination of mexiletine hydrochloride in capsules. The ion-pair formed was highly coloured and easily extracted with dichloromethane. The calibration curve was linear over the concentration range 1.08--10.8 m g.ml-1 at lmax = 408 nm (r = 0.9999). The results obtained from the developed method were compared statistically with those obt...

  6. Small-bowel neoplasms in patients undergoing video capsule endoscopy

    DEFF Research Database (Denmark)

    Rondonotti, E; Pennazio, M; Toth, E;

    2008-01-01

    BACKGROUND AND STUDY AIM: Small-bowel tumors account for 1% - 3% of all gastrointestinal neoplasms. Recent studies with video capsule endoscopy (VCE) suggest that the frequency of these tumors may be substantially higher than previously reported. The aim of the study was to evaluate the frequency...... neoplasm seen in 29 centers of 10 European Countries. RESULTS: Of 5129 patients undergoing VCE, 124 (2.4%) had small-bowel tumors (112 primary, 12 metastatic). Among these patients, indications for VCE were: obscure gastrointestinal bleeding (108 patients), abdominal pain (9), search for primary neoplasm...

  7. Serum Ceramide Kinase as a Biomarker of Cognitive Functions, and the Effect of Using Two Slimming Dietary Therapies in Obese Middle Aged Females

    Science.gov (United States)

    Moaty, Maha I. A.; Fouad, Suzanne; El Shebini, Salwa M.; Kazem, Yusr M. I.; Ahmed, Nihad H.; Mohamed, Magda S.; Hussein, Ahmed M. S.; Arafa, Atiat M.; Hanna, Laila M.; Tapozada, Salwa T.

    2015-01-01

    AIM: Highlighting the impact of obesity on mental and cognitive functions using serum ceramide kinase enzyme concentration as a biomarker for cognitive evaluation in the middle aged females, and also targeting to control the obesity and simultaneously postponing the deterioration of the cognitive functions, by implementing two slimming dietary therapies each incorporating different functional ingredients known to boost cognition. SUBJECTS AND METHODS: Ninety six obese middle aged females, divided into two groups volunteered to follow a low caloric balanced diet combined with two bread supplements composed essentially of barley flour and wheat germ mixed with either 5% turmeric, group (A); or with 5% ginger, group (B) for 4 weeks, phase (1); to be followed by the hypocaloric diet alone for another 4 weeks, phase (2). RESULTS: By the end of phase (1), the biochemical analysis showed a positive response of the levels of C-peptide and modified homeostatic model assessment of insulin resistance; also increased levels of the serum ceramide kinase enzyme, coupled with improved cognitive functions tests. Improvement of the relevant metabolic profile, fasting blood glucose, blood pressure and the anthropometric measurements was detected. CONCLUSION: Using dietary therapy supported by special formulas which contain active ingredients succeeded in reducing weight and improving both the metabolic profile and the cognitive functions. PMID:27275191

  8. Carlos Slim Helu: World's Richest Person%世界新首富卡洛斯·斯利姆·埃卢

    Institute of Scientific and Technical Information of China (English)

    王佳

    2010-01-01

    @@ 今年3月10日,美国杂志在纽约揭晓了2010年度富豪排行榜,墨西哥电信巨子卡洛斯·斯利姆·埃卢(Carlos Slim Helú)以535亿美元资产,取代美国微软公司创始人比尔·盖茨成为世界首富,①这是发展中国家人士第一次摘得这一桂冠.卡洛斯的商业帝国包括墨西哥最知名的百货商场、最大的电信运营商、酒店、餐馆、石油开采、建筑公司、银行、保险等等.难怪路透社形容:"想在墨西哥过上一天却不给卡洛斯付钱可不是件容易事."

  9. Super- and sub-Eddington accreting massive black holes: A comparison of slim and thin accretion discs through study of the spectral energy distribution

    CERN Document Server

    Castello-Mor, Nuria; Kaspi, Shai

    2016-01-01

    We employ optical and UV observations to present SEDs for two reverberation-mapped samples of super-Eddington and sub-Eddington AGN with similar luminosity distributions. The samples are fitted with accretion disc models in order to look for SED differences that depend on the Eddington ratio. The fitting takes into account measured BH mass and accretion rates, BH spin and intrinsic reddening of the sources. All objects in both groups can be fitted by thin AD models over the range 0.2-1$\\,\\mu$m with reddening as a free parameter. The intrinsic reddening required to fit the data are relatively small, $E(B-V)\\leq0.2$~mag, except for one source. Super-Eddington AGN seem to require more reddening. The distribution of $E(B-V)$ is similar to what is observed in larger AGN samples. The best fit disc models for the two groups are very different, with super-Eddington sources require much more luminous far-UV continuum. The exact amount depends on the possible saturation of the UV radiation in slim discs. In particular,...

  10. Inadvertent Trypan Blue Staining of Posterior Capsule during Cataract Surgery Associated with “Argentinian Flag” Event

    Science.gov (United States)

    Prinzi, Robert A.; Alapati, Neeti M.; Gappy, Shawn S.; Dilly, Jason S.

    2016-01-01

    Trypan blue is common in visualizing the anterior capsule during cataract surgery. Inadvertent staining of the posterior capsule during phacoemulsification is a rare complication and there are few reports in the literature. The proposed mechanism of posterior capsule staining in previous reports includes a compromised zonular apparatus or iris retractors facilitating the posterior flow of trypan blue. We report the first case of trypan blue staining of the posterior capsule associated with the “Argentinian flag” sign. In our case, the “Argentinian flag” allowed the trypan blue to seep between the posterior capsule and the lens, staining the anterior surface of the posterior capsule. PMID:27022495

  11. Chinese Foods; Teacher's Handbook.

    Science.gov (United States)

    Huang, Joe, Ed.

    Different styles of Chinese cooking, traditional food items, cooking utensils, serving techniques, and the nutritional value of Chinese cooking are described in this teaching guide. Lesson plans for the preparation of simple dishes are presented. Recipes, a shopping guide to San Francisco's Chinatown, a guide to sources of supplies, and a…

  12. Confucius Teaching Chinese Abroad

    Institute of Scientific and Technical Information of China (English)

    TANG YUANKAI

    2010-01-01

    @@ On December 1, 2009, the Confucius Institute in Lyon, France, held a plaque-unveiling ceremony. Thomas Boutonnet, a Frenchman who has studied Chinese for 10 years in France and China and who is also an institute supervisor, said the institute would offer courses in Chinese language and culture covering legal, wade and cultural fields.

  13. FROM THE CHINESE PRESS

    Institute of Scientific and Technical Information of China (English)

    1998-01-01

    Equality and harmony are mainstream in Chinese marriage. The conclusion was made by a systematic investigation in 1996 on love and marriage relations between couples in Shanghai, Harbin, Guangdong, Gansu and other regions. Six thousand couples were surveyed in a multi-period, separated level probability sampling; the research was conducted by the study group, "Marriage quality during the period of Chinese social

  14. Say That in Chinese

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Demand for Chinese language learning is fueling all aspects of the market, most notably the textbook publication industry Alarge-scale series of Chinese lan-guage textbooks are to be pub-lished in the coming years jointly by the China International Publi

  15. On Developing Business Chinese.

    Science.gov (United States)

    Hong, Wei

    1996-01-01

    Examines the significance of foreign languages for business, particularly Business Chinese, in the 1990s; its curriculum requirements; and the impact of business languages on international business. The article proposes a developmental plan for Business Chinese at the college level including goals, course materials, learning activities, and…

  16. Chinese by Choice

    Science.gov (United States)

    Beem, Kate

    2008-01-01

    A 2004 College Board survey revealed that school districts around America wanted to offer Chinese, but finding qualified teachers was a problem, says Selena Cantor, director of Chinese Language and Culture Initiatives for the College Board. So last year, a new College Board program brought guest teachers from China to school districts in 31…

  17. Equilibria of Chinese Auctions

    DEFF Research Database (Denmark)

    Branzei, Simina; Forero, Clara; Larson, Kate;

    Chinese auctions are a combination between a raffle and an auction and are held in practice at charity events or festivals. In a Chinese auction, multiple players compete for several items by buying tickets, which can be used to win the items. In front of each item there is a basket, and the play...

  18. Modern Chinese History Studies

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    Famous Foreign Scholars' Lecture Tours in China Around the May Fourth Movement and Changes in Chinese Intellectual Circles From 1919 to 1924, John Dewey and four other famous foreign scholars came to China on lecture tours. These tours were great cultural undertakings to spread Western learning to the East after the First World War. The lectures these schol- ars gave helped to deepen the thoughts of Chinese people, and at the same time encouraged the diversification and evolution of Chinese intellectual circles. Firstly, the lectures hastened the birth of a contemporary Chinese wave of reflection on mo- dernity, and provided a basis for the theoretical views and cultural appeals of Liang Qichao and other members of the socalled "Orient Culture Faction," thereby increasing the tension intrinsic to the development of the New Culture Movement and to the expansion of intellectual horizons in Chinese intellectual circles.

  19. Chinese Companies in Switzerland

    Directory of Open Access Journals (Sweden)

    Esther Kessler

    2014-10-01

    Full Text Available In recent years, some of China’s leading firms have made headlines with their European expansion, by either opening new facilities or by acquiring or merging with significant enterprises in Europe. The goal of this paper is to contribute to the existing literature by examining Chinese enterprises expanding into Switzerland. The study also allows some conclusions for Chinese companies entering Central and Eastern Europe. We analyze via interviews the motivations of Chinese companies to expand into Switzerland as well as their behavior and the impediments in their internationalization process. Our findings show that Chinese companies fail to take advantage of certain benefits of western economies (such as open information and stable rule of law. To move forward efficiently, they should develop competence in dealing systematically with readily available market information, building professional networks that recognize a separation between business life and personal life, and managing their Chinese and foreign employees in the foreign cultural environment.

  20. On Chinese Parody Translation

    Institute of Scientific and Technical Information of China (English)

    熊俊

    2013-01-01

    Chinese parody, as a traditional figure of speech, has captured more and more attention from scholars. The researches conducted up to date are inadequate in theorizing and exploring its translation. This paper, based on the comparative data analysis of Chinese parody translation examples in different types of texts, attempts to probe into the means about how to achieve the clos⁃est function equivalence in rendering Chinese parody under the guidance of Sociosemiotic Approach. It is found that the nature of Chinese parody translation is to achieve the closest natural equivalence or similarity in expressive function, informative func⁃tion, vocative function and aesthetic function in its equivalents in English. And it is suggested that borrowing, imitating, para⁃phrasing and adapting are effective strategies in translating Chinese parody.

  1. Development of the instrumented capsule for nuclear fuel irradiation test at HANARO

    International Nuclear Information System (INIS)

    The instrumented capsule for the nuclear fuel irradiation test (hereinafter referred to as 'instrumented fuel capsule'), which is crucial for the verification of a nuclear fuel performance and safety, has been developed at HANARO (High-flux Advanced Neutron Application Reactor). The irradiation test of the first instrumented fuel capsule was carried out in March 2003 and the irradiation test of the second instrumented fuel capsule was carried out in April 2004 at HANARO. Through the irradiation tests of the two capsules, the design specifications and safety of the instrumented fuel capsule were successfully verified. In the first instrumented fuel capsule, only the technologies for measuring the center temperature of the nuclear fuel and neutron flux were implemented. In the second instrumented fuel capsule, the technologies for measuring the center temperature of the nuclear fuel, the internal pressure of the fuel rod, the elongation of the nuclear fuel and the neutron flux were implemented. Currently the dual instrumented technologies that alloy for two characteristics to be measured simultaneously in one fuel rod, is being developed. The duel instrumented fuel rods have been successfully designed as a part of the technology enhancement program for the instrumented fuel capsule. The instrumented fuel capsule will be utilized for the development of nuclear fuel. The instrumentation technologies for measuring the nuclear fuel characteristics will be applied to the 3-pin FTL (Fuel Test Loop) facility which is currently being developed. And, the duel instrumented technologies will contribute to enhancing the efficiency of the irradiation test using an instrumented fuel capsule at HANARO. (author)

  2. Trial Study on DENG Tie-tao's Coronary Heart Disease Capsules in Improving Patients' Quality of Life

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Objective: To assess the efficacy of the Coronary Heart Disease (CHD) Capsules worked out by Prof. Deng--in improving quality of life of CHD patients of qi deficiency with phlegm and blood stasis syndrome. Method: According to the WHO's diagnosis criteria of CHD, a total of 93 stable angina patients were divided into 3 groups using the single blinded method. The groups were evenly distributed into CHD Capsule treated group (CHDC), isosorbide dinitrate control group (ID), and Compound Prescription Danshen Droplet Pills control group (CPDDP). Two courses of treatment lasting for 6 months were given. During the courses of treatment, the following parameters were observed: clinical symptoms of angina pectoris, ECG change, treadmill exercise test, 36 items in short form of health survey (SF-36) and Seattle Angina Questionnaire (SAQ) scale. Results: After 6 months of treatment, all the three groups showed good curative effect in angina pectoris, ECG and treadmill exercise test, differences between them had no statistical significance.The CHDC group showed a better result in nitro-glycerine stopping or alleviation rate and in improving symptoms than the other groups (P<0.05). The general health, vitality, role-emotional, mental health and reported health transition in the CHDC group were significantly better than those in the control groups (P<0.05). The scores in physiological functioningrole, physiological function and pain alleviation were not different among the three groups. Conclusion: Prof. DENG Tie-tao's CHDC is effective in treating CHD with qi deficiency, phlegm and blood stasis and also in improving the quality of life. CHDC is more suitable to be used in long-term treatment than isosorbide dinitrate. The SF-36 and SAQ can be used to appraise the curative effect of traditional Chinese medicine agents for CHD angina pectoris.

  3. Mars Science Laboratory Entry Capsule Aerothermodynamics and Thermal Protection System

    Science.gov (United States)

    Edquist, Karl T.; Hollis, Brian R.; Dyakonov, Artem A.; Laub, Bernard; Wright, Michael J.; Rivellini, Tomasso P.; Slimko, Eric M.; Willcockson, William H.

    2007-01-01

    The Mars Science Laboratory (MSL) spacecraft is being designed to carry a large rover (greater than 800 kg) to the surface of Mars using a blunt-body entry capsule as the primary decelerator. The spacecraft is being designed for launch in 2009 and arrival at Mars in 2010. The combination of large mass and diameter with non-zero angle-of-attack for MSL will result in unprecedented convective heating environments caused by turbulence prior to peak heating. Navier-Stokes computations predict a large turbulent heating augmentation for which there are no supporting flight data1 and little ground data for validation. Consequently, an extensive experimental program has been established specifically for MSL to understand the level of turbulent augmentation expected in flight. The experimental data support the prediction of turbulent transition and have also uncovered phenomena that cannot be replicated with available computational methods. The result is that the flight aeroheating environments predictions must include larger uncertainties than are typically used for a Mars entry capsule. Finally, the thermal protection system (TPS) being used for MSL has not been flown at the heat flux, pressure, and shear stress combinations expected in flight, so a test program has been established to obtain conditions relevant to flight. This paper summarizes the aerothermodynamic definition analysis and TPS development, focusing on the challenges that are unique to MSL.

  4. A new capsule platinum resistance thermometer for cryogenic use

    Science.gov (United States)

    Courts, S. S.; Krause, J. K.

    2013-09-01

    Standards grade platinum resistance thermometers (SPRTs) obtain their high stability in part due to the strain-free mounting of the sensing wire. The space required for this strain-free mounting normally results in thermometers on the order of 6 mm diameter by 40 mm length in size. While these SPRTs are acceptable in many applications, it is desirable to reduce the size as much as possible for cryogenic use where space is of major concern. For over 40 years Minco Products, Inc. provided a smaller alternative with their model S1059, a high-stability cryogenic capsule platinum resistance thermometer (PRT) packaged in a copper canister sized only 3.2 mm diameter by 9.7 mm length. The packaging was compatible for use over the 13 K to 533 K temperature range. Unfortunately, this product was discontinued in 2009. In its absence, Lake Shore Cryotronics, Inc., has worked with Advanced Sensing Products to develop a similarly sized replacement sensor for cryogenic use. The replacement capsule PRT is manufactured using the model S1059 design, but with modifications to reduce the chance of lead breakage at the epoxy-lead interface. Test devices have been fabricated and tested for temperature response and stability upon repeated calibration from 13 K to 330 K. The new sensor design features and performance data are presented in this work.

  5. [Is capsule endoscopy useful in children with chronic abdominal pain?].

    Science.gov (United States)

    Argüelles-Arias, F; Argüelles Martín, F; Caunedo Alvarez, A; Sánchez Yagüe, A; Romero Vázquez, J; García Montes, M J; Rodríguez-Téllez, M; Pellicer Bautista, F J; Herrerías Gutiérrez, J M

    2007-10-01

    Chronic abdominal pain is highly prevalent in school-aged children and is one of the most frequent disorders in our environment. The aim of the present study was to evaluate the usefulness of capsule endoscopy (CE) in patients with chronic abdominal pain. Sixteen patients (nine boys and seven girls), aged between 5 and 16 years old, with chronic abdominal pain for at least 12 months were studied. In all patients the results of hemograms, biochemical investigations, urine sediment test, Helicobacter pylori breath test and celiac serology were normal. In all children, gastroscopy, small bowel follow-through, abdominal ultrasound and colonoscopy were normal. All patients received CE by mouth. In 43.75 % of the patients studied (7/16), the capsule showed evidence of nodular lymphoid hyperplasia, mainly located in the ileum. In one girl, oxyuriasis was observed in the cecum and in another girl aphthous lesions were observed in the ileum. These lesions suggested small bowel Crohn's disease. CE mainly showed images compatible with nodular lymphoid hyperplasia, with unknown clinical significance. Consequently, we conclude that CE does not provide useful information in patients with abdominal pain without other symptoms. PMID:17949651

  6. Five years' experience with capsule endoscopy in a single Center

    Institute of Scientific and Technical Information of China (English)

    Taylan Kav; Yusuf Bayraktar

    2009-01-01

    Capsule endoscopy (CE) is a novel technology that facilitates highly effective and noninvasive imaging of the small bowel. Although its efficacy in the evaluation of obscure gastrointestinal bleeding (OGIB) has been proven in several trials, data on uses of CE in different small bowel diseases are rapidly accumulating in the literature, and it has been found to be superior to alternative diagnostic tools in a range of such diseases.Based on literature evidence, CE is recommended as a first-line investigation for OGIB after negative bidirectional endoscopy. CE has gained an important role in the diagnosis and follow-up of Crohn's disease and celiac disease and in the surveillance of small bowel tumors and polyps in selected patients. Capsule retention is the major complication, with a frequency of 1%-2%. The purpose of this review was to discuss the procedure, indications, contraindications and adverse effects associated with CE. We also review and share our five-year experience with CE in various small bowel diseases. The recently developed balloon-assisted enteroscopies have both diagnostic and therapeutic capability. At the present time, CE and balloon-assisted enteroscopies are complementary techniques in the diagnosis and management of small bowel diseases.

  7. In situ lyophilisation of nifedipine directly in hard gelatine capsules.

    Science.gov (United States)

    Crum, Matthew; Elkordy, Amal Ali; Zarara, Moataz; Elkordy, Eman Ali

    2013-01-01

    Hydrophobic drugs present a challenge due to: (i) adhesion and agglomeration; hence the choice of the suitable processing technique to have the drugs into orally administered dosage forms is critical. (ii) Poor dissolution and poor aqueous solubility; hence poor bioavailability. A novel method which is in situ lyophilisation directly in hard gelatin capsule shells was used in this research to enhance the dissolution of nifedipine (a model hydrophobic drug) in the presence of co-povidone, Pluronic(®)F-127 and inulin as enhancement excipients (to the best of our knowledge those excipients have not been previously used with nifedipine in lyophilised forms). Solutions of nifedipine and excipients in a range of concentrations (0.5, 1, 5 and 10%w/v) were prepared using a co-solvent system of tert- butyl alcohol/water mixture. These solutions were filled directly into bodies of size 000 hard gelatin capsule shells and freeze dried. Pure drug and all formulations were characterised by solubility, wetting studies and in vitro dissolution. Also, conformational integrity and thermal characteristics of nifedipine formulations were investigated using FT-IR spectroscopy and differential scanning calorimetry (DSC), respectively. The in situ lyophilisation of nifedipine with excipients, looks a promising method not only to improve the hydrophobic drug dissolution but also to be cost effective. PMID:22992055

  8. Theoretical study of symmetry of flux onto a capsule

    International Nuclear Information System (INIS)

    An analytic model to describe the flux asymmetry onto a capsule based on the viewfactor approximation is developed and verified with numerical simulations. By using a nested spheres technique to represent the various sources of flux asymmetry, the model can treat spherically and cylindrically symmetric hohlraums, e.g., cylinder, elliptic, and rugby. This approach includes the more realistic case of frequency-dependent flux asymmetry compared with the more standard frequency-integrated or single-frequency approaches [D. W. Phillion and S. M. Pollaine, Phys. Plasmas 1, 2963 (1994)]. Correspondingly, the approach can be used to assess x-ray preheat asymmetry generated from localized laser absorption in the high-Z hohlraum wall. For spherical hohlraums with 4, 6, or 8 laser entrance holes (LEHs), an optimal configuration of LEHs, laser spot placement, and angle-of-incidence of the single-ringed laser beams is defined. An analogy between minimizing the flux asymmetry onto a capsule and the Thomson problem of point charge placement on a sphere for minimized energy is shown

  9. Theoretical study of symmetry of flux onto a capsule

    Energy Technology Data Exchange (ETDEWEB)

    Duan, Hao; Wu, Changshu; Zou, Shiyang, E-mail: duan-hao@iapcm.ac.cn [Institute of Applied Physics and Computational Mathematics, Beijing 100094 (China); Pei, Wenbing [Shanghai Institute of Laser Plasma, China Academy of Engineering Physics, Shanghai 201800 (China)

    2015-09-15

    An analytic model to describe the flux asymmetry onto a capsule based on the viewfactor approximation is developed and verified with numerical simulations. By using a nested spheres technique to represent the various sources of flux asymmetry, the model can treat spherically and cylindrically symmetric hohlraums, e.g., cylinder, elliptic, and rugby. This approach includes the more realistic case of frequency-dependent flux asymmetry compared with the more standard frequency-integrated or single-frequency approaches [D. W. Phillion and S. M. Pollaine, Phys. Plasmas 1, 2963 (1994)]. Correspondingly, the approach can be used to assess x-ray preheat asymmetry generated from localized laser absorption in the high-Z hohlraum wall. For spherical hohlraums with 4, 6, or 8 laser entrance holes (LEHs), an optimal configuration of LEHs, laser spot placement, and angle-of-incidence of the single-ringed laser beams is defined. An analogy between minimizing the flux asymmetry onto a capsule and the Thomson problem of point charge placement on a sphere for minimized energy is shown.

  10. Development of CMOS Imager Block for Capsule Endoscope

    Science.gov (United States)

    Shafie, S.; Fodzi, F. A. M.; Tung, L. Q.; Lioe, D. X.; Halin, I. A.; Hasan, W. Z. W.; Jaafar, H.

    2014-04-01

    This paper presents the development of imager block to be associated in a capsule endoscopy system. Since the capsule endoscope is used to diagnose gastrointestinal diseases, the imager block must be in small size which is comfortable for the patients to swallow. In this project, a small size 1.5V button battery is used as the power supply while the voltage supply requirements for other components such as microcontroller and CMOS image sensor are higher. Therefore, a voltage booster circuit is proposed to boost up the voltage supply from 1.5V to 3.3V. A low power microcontroller is used to generate control pulses for the CMOS image sensor and to convert the 8-bits parallel data output to serial data to be transmitted to the display panel. The results show that the voltage booster circuit was able to boost the voltage supply from 1.5V to 3.3V. The microcontroller precisely controls the CMOS image sensor to produce parallel data which is then serialized again by the microcontroller. The serial data is then successfully translated to 2fps image and displayed on computer.

  11. Design Considerations for a Cone in a Fast Ignition Capsule

    International Nuclear Information System (INIS)

    An alternative to inertial fusion with central ignition is 'fast ignition', in which one laser compresses the DT fuel adiabatically and a second laser with a short, very intense pulse heats the compressed core with super-thermal electrons. One approach to fast ignition entails the introduction of the second laser beam via a hollow cone that pierces the side of the capsule. Critical considerations for the design of the cone in such an experiment include: (1) perturbation of the implosion by the cone; (2) minimization of the column density of material between the critical density surface for the ignitor beam and the converged high density region; (3) positioning, alignment, and shape of the cone to minimize deleterious hydrodynamic effects; and (4) effect of radiation gradients around the cone on the symmetry of the implosion. This study entails the 2D and 3D simulations of a fast-ignitor experiment having a cryogenic deuterium-tritium capsule imploded within a high-Z hohlraum heated by about 650 kJ of 3ω laser beams on the NIF.

  12. Little Joe (LJ1) after accidental launch of capsule

    Science.gov (United States)

    1959-01-01

    Testing of the Little Joe booster on its launcher. The launcher is positioned at its normal launch angle of 80 degrees. Joseph Shortal wrote (vol. 3, p. 33): 'The Little Joe booster was assembled at Wallops on its special launcher in a vertical attitude. It is shown in the [on the left] with the work platform in place. The launcher was located on a special concrete slab in Launching Area 1. The capsule was lowered onto the booster by crane.... After the assembly was completed, the scaffolding was disassembled and the launcher pitched over to its normal launch angle of 80 degrees.... Little Joe had a diameter of 80 inches and an overall length, including the capsule and escape tower of 48 feet. The total weight at launch was about 43,000 pounds. The overall span of the stabilizing fins was 21.3 feet.' 'Although in comparison with the overall Mercury Project, Little Joe was a simple undertaking, the fact that an attempt was made to condense a normal two-year project into a 6-month one with in house labor turned it into a major undertaking for Langley.'

  13. 开郁胶囊对抑郁动物模型的影响%Effects of Kaiyu Capsule on Depression-like Animal Models

    Institute of Scientific and Technical Information of China (English)

    李雅莉; 赵玲; 魏海峰; 李林

    2011-01-01

    目的:开郁胶囊是本室自行研制的由8种传统中药组成的中药新复方制剂,本研究观察开郁胶囊对数种抑郁动物模型的影响.方法:采用ICR小鼠随机分为对照组、开郁胶囊低、中、高剂量组(按生药量计为6.6,13.2,26.4 g·kg-1)及阳性对照药帕罗西汀组.连续ig14 d,于末次给药1.5 h后采用小鼠悬尾、强迫游泳、5-羟色胺酸(5-HTP)诱导甩头及利血平拮抗实验动物模型,评价开郁胶囊的抗抑郁作用.结果:与对照组相比,开郁胶囊中、高剂量组能显著缩短小鼠悬尾不动时间(P<0.05);开郁胶囊高剂量组显著增加5-HTP诱导的小鼠甩头次数(P<0.01),缩短甩头潜伏期(P<0.05).注射利血平后动物出现利血平化,即眼睑下垂、体温下降及活动抑制;开郁胶囊中、高剂量ig14 d,可改善利血平化小鼠的眼睑下垂及活动抑制(P<0.01),对体温下降亦有显著的拮抗作用(P<0.01).结论:开郁胶囊对拟抑郁症小鼠模型具有明显的拮抗作用,其作用机制可能与增强5-羟色胺能和去甲肾上腺素能神经功能有关.%Objective:Kaiyu capsule is a new compound preparation which consists of 8 traditional Chinese herbs. The purpose of the study was to investigate the effects of Kaiyu capsule on depression-like animal models.Method: ICR mice were randomly allocated to five groups: control, Kaiyu capsule low, middle and high dose groups (6. 6,13.2, 26. 4 g· kg - 1 accordingly), and Paroxetine ( positive control). After intragastric administration for 14 d, the antidepressant effect of Kaiyu capsule was evaluated by using mice tail suspension test, mice forced swimming test, 5-hydroxytryptophan (5-HTP)-induced head-twitches and reserpine reversal model in mice.Result: Compared with control group, the middle and high doses of Kaiyu capsule significantly decreased the accumulative immobility time in mice tail suspension test( P < 0. 05 ). High dose Kaiyu capsule obviously increased the

  14. Study on Translating Chinese into Chinese Sign Language

    Institute of Scientific and Technical Information of China (English)

    徐琳; 高文

    2000-01-01

    Sign language is a visual-gestural language mainly used by hearing impaired people to communicate with each other. Gesture and facial expression are important grammar parts of sign language. In this paper, a text-based transfor mation method of Chinese-Chinese sign language machine translation is proposed.Gesture and facial expression models are created. And a practical system is im plemented. The input of the system is Chinese text. The output of the system is "graphics person" who can gesticulate Chinese sign language accompanied by facial expression that corresponds to the Chinese text entered so as to realize automatic translation from Chinese text to Chinese sign language.

  15. Chinese nuclear insurance and Chinese nuclear insurance pool

    International Nuclear Information System (INIS)

    Chinese Nuclear Insurance Started with Daya Bay Nuclear Power Station, PICC issued the insurance policy. Nuclear insurance cooperation between Chinese and international pool's organizations was set up in 1989. In 1996, the Chinese Nuclear Insurance Pool was prepared. The Chinese Nuclear Insurance Pool was approved by The Chinese Insurance Regulatory Committee in May of 1999. The principal aim is to centralize maximum the insurance capacity for nuclear insurance from local individual insurers and to strengthen the reinsurance relations with international insurance pools so as to provide the high quality insurance service for Chinese nuclear industry. The Member Company of Chinese Nuclear Pool and its roles are introduced in this article

  16. Research in Ancient Chinese Language

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    JIANG Ji-cheng, A Brief Study of Arabian-Chinese Diaphone in Huihui Prescription Abstract: Based on meterials of Arabian- Chinese diaphone in Huihui Prescription, this paper studies all Chinese phonetic initials and finals in Yuan dynasty, including 21 initials and 34 finals. Key Words: Huihui Prescription, Arabian- Chinese diaphone, transferred sound, International Phonetic Alphabet

  17. Genetic Characterization of the Capsulation Locus of Haemophilus influenzae Serotype e▿

    OpenAIRE

    Giufrè, Maria; Cardines, Rita; Mastrantonio, Paola; Cerquetti, Marina

    2010-01-01

    The capsulation (cap) locus of Haemophilus influenzae type e (Hie) was characterized and sequenced. No IS1016 element was found to flank the locus. The 18.2-kb locus included 14 open reading frames (ORFs), which were grouped into three functional regions. Eight new ORFs (named ecs1 to ecs8) were identified in the Hie capsule-specific region II.

  18. Cross-type optical separation of elastic oblate capsules in a uniform flow

    International Nuclear Information System (INIS)

    The dynamic behavior of an elastic capsule with an initially oblate spheroidal shape during cross-type optical separation was numerically investigated. The penalty immersed boundary method was adopted for the fluid-membrane interaction, and the optical force calculation was conducted by using the ray optics method including the ray-surface intersection algorithm. The oblate elastic capsule of b/a = 0.5 with different surface Young's moduli and different initial inclination angles was considered. The oblate capsule with higher surface Young's moduli was less deformed, and was more migrated for each initial inclination angle. Unlike the oblate rigid particle, the initially inclined capsules with moderate inclination angles were similarly migrated since the oblate elastic capsule was deformed during rotation near the laser beam axis. The oblate capsules can be separated according to the surface Young's modulus, except for nearly non-inclined capsules. As the fluid velocity decreased, the migration distance increased. The maximum deformation parameter was insensitive to the fluid velocity. Furthermore, a new dimensionless number (Sec) was introduced to predict the migration distance of the oblate elastic capsule

  19. 21 CFR 520.2345f - Tetracycline phosphate complex and sodium novobiocin capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Tetracycline phosphate complex and sodium... ANIMAL DRUGS § 520.2345f Tetracycline phosphate complex and sodium novobiocin capsules. (a) Specifications. Each capsule contains the equivalent of 60 milligrams of tetracycline hydrochloride and...

  20. Some Specialities of Neutral Buoyancy Hydraulic Capsules Flow in Horizontal Pipe

    Czech Academy of Sciences Publication Activity Database

    Berman, V.; Vlasák, Pavel

    Tel Aviv, 2015. [The 8th International Conference for Conveying and Handling of Particulate Solids. Tel Aviv (IL), 03.05.2015-07.05.2015] Institutional support: RVO:67985874 Keywords : capsule velocity * shear stress * cylindrical capsules Subject RIV: BK - Fluid Dynamics

  1. Effect of preparation conditions on properties and permeability of chitosan-sodium hexametaphosphate capsules.

    Science.gov (United States)

    Angelova, N; Hunkeler, D

    2001-01-01

    Capsules were obtained by interpolymer complexation between chitosan (polycation) and sodium hexametaphosphate (SMP, oligoanion). The effect of the preparation conditions on the capsule characteristics was evaluated. Specifically, the influence of variables such as pH, ionic strength, reagent concentration, and additives on the capsule permeability properties was investigated using dextran as a model permeant. The capsule membrane permeability was found to increase by decreasing the chitosan/SMP ratio as well as adding mannitol to the oligoanion recipient bath. Increasing the ionic strength or the pH of the initial chitosan solution was also found to enhance the membrane permeability, moving the membrane exclusion limit to higher values. Generally, the capsules prepared tinder all tested conditions had a relatively low permeability which rarely exceeded a molecular cut-off of 40 kD based on dextran standards. Furthermore, the diffusion rate showed a strong temporal dependence, indicating that the capsules prepared under various conditions exhibit different apparent pore size densities on the surface. The results indicated that, in order to obtain the desired capsule mass-transfer properties, the preparation conditions should be carefully considered and adjusted. Adding a polyol as well as low salt amount (less than 0.15%) is preferable as a means of modulating the diffusion characteristics, without disturbing the capsule mechanical stability. PMID:11922478

  2. Improved Water Barrier Properties of Calcium Alginate Capsules Modified by Silicone Oil

    Directory of Open Access Journals (Sweden)

    Brian G. Zukas

    2016-04-01

    Full Text Available Calcium alginate films generally offer poor diffusion resistance to water. In this study, we present a technique for encapsulating aqueous drops in a modified calcium alginate membrane made from an emulsion of silicone oil and aqueous alginate solution and explore its effect on the loss of water from the capsule cores. The capsule membrane storage modulus increases as the initial concentration of oil in the emulsion is increased. The water barrier properties of the fabricated capsules were determined by observing the mass loss of capsules in a controlled environment. It was found that capsules made with emulsions containing 50 wt% silicone oil were robust while taking at least twice the time to dry completely as compared to capsules made from only an aqueous alginate solution. The size of the oil droplets in the emulsion also has an effect on the water barrier properties of the fabricated capsules. This study demonstrates a facile method of producing aqueous core alginate capsules with a modified membrane that improves the diffusion resistance to water and can have a wide range of applications.

  3. Tissue responses against immunoisolating alginate-PLL capsules in the immediate posttransplant period

    NARCIS (Netherlands)

    de Vos, P; van Hoogmoed, CG; de Haan, BJ; Busscher, HJ

    2002-01-01

    Alginate-polylysine (PLL) capsules are commonly applied for immunoisolation of living cells for the treatment of a wide variety of diseases. Large-scale application of the technique, however, is hampered by insufficient biocompatibility of the capsules with failure of the grafts as a consequence. Mo

  4. Klebsiella pneumoniae capsule expression is necessary for colonization of large intestines of streptomycin-treated mice

    DEFF Research Database (Denmark)

    Favre-Bonte, S.; Licht, Tine Rask; Forestier, C.; Krogfelt, K. A.

    1999-01-01

    The role of the Klebsiella pneumoniae capsular polysaccharide (K antigen) during colonization of the mouse large intestine was assessed with mild-type K. pneumoniae LM21 and its isogenic capsule-defective mutant. When bacterial strains were fed alone to mice, the capsulated bacteria persisted in...

  5. Design, development and test of a compact lightweight capsule recovery system

    NARCIS (Netherlands)

    Hausmann, G.; De Pascale, F.; Kruijff, M.; Mironov, M.

    2008-01-01

    This paper reports about the development and test of a recovery system for small capsules, originally developed for the YES2 satellite launched in 2007, that included a miniature re-entry capsule, Fotino. The system includes a beacon and parachute, an activation system, and a compact spring-based pa

  6. Fabrication and operation of HFIR-MFE RB spectrally tailored irradiation capsules

    International Nuclear Information System (INIS)

    The objective of this work is to fabricate and operate irradiation capsules for irradiating magnetic fusion energy (MFE) first-wall materials in the High Flux Isotope Reactor (HFIR) removable beryllium (RB) positions. Japanese and US MFE specimens are being transferred to RB positions following irradiation to 7.5 dpa at temperatures of 60, 200, 330, and 400C in Oak Ridge Research Reactor (ORR) experiments ORR-MFE-6J and -7J. Fabrication and operation of four HFIR-MFE RB capsules (60, 200, 330, and 400C) to accommodate MFE specimens previously irradiated in spectrally tailored experiments in the ORR are proceeding satisfactorily. With the exception of the 60C capsule, where the test specimens are in direct contact with the reactor cooling water, the specimen temperatures (monitored by 21 thermocouples) are controlled by varying the thermal conductance of a small gap region between the specimen holder and the containment tube. Irradiation of the 60 and 330C capsules was started on July 17, 1990. As of September 30, 1991, these two capsules had completed 12 cycles of their planned 28-cycle irradiation to a damage level of 20 displacements per atom (dpa). Fabrication of parts for the other two (200 and 400C capsules) is complete. Assembly of the 200 and 400C capsules is scheduled for completion in FY 1993; operation of these two capsules will follow the first two (60 and 330C)

  7. Detection and genetic analysis of group II capsules in Aeromonas hydrophila.

    Science.gov (United States)

    Zhang, Y L; Lau, Y L; Arakawa, E; Leung, K Y

    2003-04-01

    The genetic organization and sequences of the group II capsule gene cluster of Aeromonas hydrophila PPD134/91 have been determined previously. The purified capsular polysaccharides can increase the ability of avirulent strain PPD35/85 to survive in naive tilapia serum but have no inhibitory effect on the adhesion of PPD134/91 to carp epithelial cells. In this study, the presence of group II capsules among 33 randomly chosen A. hydrophila strains was examined by electron microscopy and genetic analysis. Ten strains were found to produce group II capsules. A PCR detection system was developed to identify two types of group II capsules (IIA and IIB) based on their genetic organization in the region II gene clusters. Group IIA capsules in the authors' collection of A. hydrophila strains are mainly found in the O : 18 and O : 34 serogroups, while group IIB capsules are found in the O : 21 and O : 27 serogroups. The presence of group II capsules in A. hydrophila strongly correlates with the serum and phagocyte survival abilities (seven out of ten strains). The results indicate that the authors' PCR detection system can constitute a reliable assay for the classification of group II capsules in A. hydrophila. PMID:12686647

  8. The role of capsule endoscopy after negative CT enterography in patients with obscure gastrointestinal bleeding

    International Nuclear Information System (INIS)

    The aim of the present study was to evaluate the role of capsule endoscopy in patients with obscure gastrointestinal bleeding (OGIB) after negative computed tomographic (CT) enterography. We retrospectively included 30 patients with OGIB who received capsule endoscopy after negative CT enterography. The median age of the patients was 60 years, and 60% of patients were male. The median follow-up duration was 8 months. Overt bleeding was 60%, and occult bleeding was 40%. Based on capsule endoscopy results, a definitive diagnosis was made for 17 patients (57%): ulcer in nine patients (30%), active bleeding with no identifiable cause in five (17%), angiodysplasia in two (7%) and Dieulafoy's lesion in one (3%). Two patients with jejunal ulcers were diagnosed with Crohn's disease. Seven patients (41%) with positive capsule endoscopy received double balloon enteroscopy and two patients (12%) received steroid treatment for Crohn's disease. Patients with overt bleeding, a previous history of bleeding, or who received large amounts of blood transfusions were more likely to show positive capsule endoscopy. Capsule endoscopy showed high diagnostic yields in patients with OGIB after negative CT enterography and may help to provide further therapeutic plans for patients with OGIB and negative CT enterography. circle CT enterography has been widely used in evaluating obscure gastrointestinal bleeding (OGIB). circle Capsule endoscopy showed high diagnostic yield for OGIB after negative CT enterography. circle Negative CT enterography does not exclude important causes of small bowel bleeding. circle Most lesions missed at CT-enterography are flat and can be detected by capsule endoscopy. (orig.)

  9. Effects of plasma physics on capsule implosions in gas-filled hohlraums

    Energy Technology Data Exchange (ETDEWEB)

    Lindman, E.L.; Delamater, N.D.; Magelssen, G.R.; Hauer, A.

    1994-10-01

    Initial experiments on capsule implosions in gas-filled hohlraums have been carried out on the NOVA Laser at Lawrence Livermore National Laboratory. Observed capsule shapes from preliminary experiments are more oblate than predicted. Improvements in modeling required to calculate these experiments and additional experiments are being pursued.

  10. Summary of the irradiation history of the TRIST-ER1 capsule

    Energy Technology Data Exchange (ETDEWEB)

    Qualls, A.L.; Eatherly, W.S.; Heatherly, D.W. [Oak Ridge National Lab., TN (United States)

    1996-10-01

    The TRIST-ERI capsule was assembled and irradiated in a large Removable Beryllium (RB{star}) position of the High Flux Isotope Reactor (HFIR) during this reporting period. Irradiation began on March 8, 1996, was completed on June 20, 1996, during operating cycles 344, 345, and 346. This report describes the thermal operation of the capsule.

  11. Visual quality inspection of capsule heads utilizing shape and gray information

    Science.gov (United States)

    Wang, Qi; Zhang, Tie; Cai, Zhenlin; Jiang, Nan; Wu, Jiamei; Zhang, Xiangde

    2015-11-01

    Capsule quality inspection is important and necessary in the pharmaceutical industry. The popular methods often mis-detect capsule head defects. To solve this problem, we propose a high-quality visual defect inspection method for capsule heads. In detail, first, capsule head images are captured by high-speed cameras with ring illuminators. Then, radial symmetry transform (RST) is employed to locate region of interest (ROI). Next, the ROI image is enhanced by homomorphic filter and binarized by basic global thresholding. After that, six discriminative features of ROI are extracted, which are skeleton feature, binary density, number of connected boundaries, RST power, mean, and variance. Finally, these features are classified by support vector machine to inspect the quality of the capsule head. The experiment is carried out on a self-established capsule image database, Northeastern University Capsule Image Database Version 1.0. According to our experiment, the proposed method can detect ROI correctly for all of the capsule head images and inspection accuracy achieves a true positive rate of 100.00% and true negative rate of 100.00%.

  12. Design and fabrication of a capsule for a material irradiation in an OR hole of HANARO

    International Nuclear Information System (INIS)

    This paper focuses on the design of a capsule for a material irradiation that is supposed to be loaded in an OR test hole in HANARO. Nuclear characteristics for the test holes of HANARO were analyzed for this purpose. A test for a pressure drop and a vibration of this capsule was performed before manufacturing a material capsule suitable for an OR hole in HANARO. In the basic design, capsules with an outside diameter of 50, 52, 54, 56 mm were reviewed theoretically to establish if they met the hydraulic requirements in HANARO. It was estimated that the diameter of a capsule for an OR holes should be more than 49 mm by an evaluation of the flow rate and pressure drop in theory. After a pressure drop test, the capsules with a diameter of 54 and 56 mm were selected and the flow rates were measured in the HANARO operation conditions. Using the velocity data measured at the single channel test loop of the outer core test facility, the heat transfer coefficient was reviewed and the temperature on the surface of the capsule was evaluated to confirm that it was less than the ONB temperature. Finally, a thermal performance test was performed using a mock-up capsule made with the out-pile test results. (author)

  13. Development of irradiation capsules in liquid metal environment in Joyo and their application to irradiation creep measurement of vanadium alloys

    International Nuclear Information System (INIS)

    In order to perform irradiation experiments in a liquid metal environment in a nuclear reactor, an irradiation technique with sodium bonding irradiation capsules was developed and a series of neutron irradiation experiments with sodium bonding irradiation capsules were performed in Joyo. The design and fabrication of sodium bonding capsules, sodium filling into capsules, capsule loading to Joyo, irradiation experiments, dismantling for irradiated capsules, removing the irradiated specimens from sodium-filled capsules, and sodium cleaning of the irradiated specimens were established through this study. Using the Joyo irradiation with the sodium bonding capsules where irradiation temperature was distributed uniformly, the irradiation creep experiment for highly purified V-4Cr-4Ti alloys, NIFS-Heat, was carried out and the knowledge about the irradiation creep behavior of the alloys was obtained. (author)

  14. Small bowel capsule endoscopy in patients with cardiac pacemakers and implantable cardioverter defibrillators: Outcome analysis using telemetry review

    OpenAIRE

    2012-01-01

    AIM: To determine if there were any interactions between cardiac devices and small bowel capsules secondary to electromagnetic interference (EMI) in patients who have undergone small bowel capsule endoscopy (SBCE).

  15. Batch processing of geometric parameters and wall thickness distribution calculation of ICF capsule by X-ray imaging method

    International Nuclear Information System (INIS)

    The basic principle of micro-focus X-ray imaging was analyzed. An improved Hough transform method was applied to automatically detect circle parameters of the capsule X-ray digital image, and precise multi-layer capsule geometric parameters were obtained by combining the least squares circle fitting algorithm. The whole image analysis procedure of batch processing was also introduced and a complete capsule X-ray image batch computing software was developed. The wall thickness distribution of the capsule batch calculation was discussed based on the above work. Some examples of the wall thickness distribution of a multi-layer capsule and the whole surface distribution of a monolayer capsule were calculated. This work will contribute to the rapid automatic capsule geometry measurement, and provide more detailed capsule geometry parameters to meet the growing requirements of target fabrication tasks. (authors)

  16. Influence of KeGan Capsule to Mice with CC14 Chronic Hepatic Injury

    Institute of Scientific and Technical Information of China (English)

    XUYufang

    2004-01-01

    To study the action of KeGan capsule to resist injury of hepatic cells and fibrosis of liver. Methods Rephcate model of chronic hepatic injury with CC14, at the beginning of which KeGan capsule was applied; finishing experiment, respectively tested the level of liver fimction, TP,ALB, A/G, L-hydroxyproline and liver index and do pathologic examination to fiver. Results KeGan capsule can obviously reduce the degree of fibrosis of liver and the level of L - hydroxyproline, improve the fiver function. The histological examination showed that capsule has the action of protecting hepatic cells from injury and resisting fibrosis of fiver either. Conclusion For KeGan capsule has the action of resisting injury of liver cells and fibrosis of liver, it' s hoped to be applied in precaution and treatment of fibrosis of fiver.

  17. Ignition capsules with aerogel-supported liquid DT fuel for the National Ignition Facility

    Directory of Open Access Journals (Sweden)

    Ho D.D.-M.

    2013-11-01

    Full Text Available For high repetition-rate fusion power plant applications, capsules with aerogel-supported liquid DT fuel can have much reduced fill time compared to β-layering a solid DT fuel layer. The melting point of liquid DT can be lowered once liquid DT is embedded in an aerogel matrix, and the DT vapor density is consequently closer to the desired density for optimal capsule design requirement. We present design for NIF-scale aerogel-filled capsules based on 1-D and 2-D simulations. An optimal configuration is obtained when the outer radius is increased until the clean fuel fraction is within 65 – 75% at peak velocity. A scan (in ablator and fuel thickness parameter space is used to optimize the capsule configurations. The optimized aerogel-filled capsule has good low-mode robustness and acceptable high-mode mix.

  18. Criteria for cesium capsules to be shipped as special form radioactive material

    International Nuclear Information System (INIS)

    The purpose of this report is to compile all the documentation which defines the criteria for Waste Encapsulation and Storage Facility (WESF) cesium capsules at the IOTECH facility and Applied Radiant Energy Corporation (ARECO) to be shipped as special form radioactive material in the Beneficial Uses Shipping System (BUSS) Cask. The capsules were originally approved as special form in 1975, but in 1988 the integrity of the capsules came into question. WHC developed the Pre-shipment Acceptance Test Criteria for capsules to meet in order to be shipped as special form material. The Department of Energy approved the criteria and directed WHC to ship the capsules at IOTECH and ARECO meeting this criteria to WHC as special form material

  19. Failure of the capsule 74F-2A for fuel compacts irradiation

    International Nuclear Information System (INIS)

    Capsule 74F-2A is for irradiation at 16000C for VHTR fuel compacts in JMTR. However, an irradiation with the capsule was suspended and the capsule was taken out, because the compacts temperature suddenly rose when the reactor power had reached to 40 MW and FPs gas was released from the compacts container during a reactor power decrease about 1-hour after the temperature rise. Subsequent examinations showed that the trouble was caused by sudden gas evolution from the flame-sprayed molybdenum coating on a graphite sleeve containing fuel compacts when the sleeve temperature exceeded a certain level. Described are the situation of temperature rise and FPs gas release, the abnormal phenomena viewed in design, fabrication and inspection of the capsule, the results of its dismounting in a hot cell, the gas releases from various capsule structural materials at elevated temperatures, and the cause as above revealed, and countermeasures to be taken in future. (author)

  20. Quantitative Characterization of Inertial Confinement Fusion Capsules Using Phase Contrast Enhanced X-Ray Imaging

    International Nuclear Information System (INIS)

    Current designs for inertial confinement fusion capsules for the National Ignition Facility (NIF) consist of a solid deuterium-tritium (D-T) fuel layer inside of a copper doped beryllium capsule. Phase contrast enhanced x-ray imaging is shown to render the D-T layer visible inside the Be(Cu) capsule. Phase contrast imaging is experimentally demonstrated for several surrogate capsules and validates computational models. Polyimide and low density divinyl benzene foam capsules were imaged at the Advanced Photon Source synchrotron. The surrogates demonstrate that phase contrast enhanced imaging provides a method to characterize surfaces when absorption imaging cannot be used. Our computational models demonstrate that a rough surface can be accurately reproduced in phase contrast enhanced x-ray images

  1. Ignition Capsules with Aerogel-Supported Liquid DT Fuel For The National Ignition Facility

    International Nuclear Information System (INIS)

    For high repetition-rate fusion power plant applications, capsules with aerogel-supported liquid DT fuel can have much reduced fill time compared to β-layering a solid DT fuel layer. The melting point of liquid DT can be lowered once liquid DT is embedded in an aerogel matrix, and the DT vapor density is consequently closer to the desired density for optimal capsule design requirement. We present design for NIF-scale aerogel-filled capsules based on 1-D and 2-D simulations. An optimal configuration is obtained when the outer radius is increased until the clean fuel fraction is within 65-75% at peak velocity. A scan (in ablator and fuel thickness parameter space) is used to optimize the capsule configurations. The optimized aerogel-filled capsule has good low-mode robustness and acceptable high-mode mix.

  2. Using gamma-ray emission to measure areal density of inertial confinement fusion capsules

    International Nuclear Information System (INIS)

    Fusion neutrons streaming from a burning inertial confinement fusion capsule generate gamma rays via inelastic nuclear scattering in the ablator of the capsule. The intensity of gamma-ray emission is proportional to the product of the ablator areal density (ρR) and the yield of fusion neutrons, so by detecting the gamma rays we can infer the ablator areal density, provided we also have a measurement of the capsule's total neutron yield. In plastic-shell capsules, for example, 12C nuclei emit gamma rays at 4.44 MeV after excitation by 14.1 MeV neutrons from D+T fusion. These gamma rays can be measured by a new gamma-ray detector under development. Analysis of predicted signals is in progress, with results to date indicating that the method promises to be useful for diagnosing imploded capsules.

  3. Success factors of Chinese restaurants

    OpenAIRE

    Aakala, Liwen Heli

    2009-01-01

    The objectives of the thesis fall into three aspects: 1) understanding Chinese entrepreneurship through some major aspects; such as, the characteristics of Chinese entrepreneur and successful skills needed; 2) scanning the Chinese culture that is associated with their entrepreneurial success in restaurant business as well as understanding the Finnish culture that affects Chinese restaurants’ presence in Finland; 3) acquainting with the competitive strategies that those Chinese restaurants emp...

  4. Fabrication of Biobased Polyelectrolyte Capsules and Their Application for Glucose-Triggered Insulin Delivery.

    Science.gov (United States)

    Shi, Dongjian; Ran, Maoshuang; Zhang, Li; Huang, He; Li, Xiaojie; Chen, Mingqing; Akashi, Mitsuru

    2016-06-01

    To enhance the glucose sensitivity and self-regulated release of insulin, biobased capsules with glucose-responsive and competitive properties were fabricated based on poly(γ-glutamic acid) (γ-PGA) and chitosan oligosaccharide (CS) polyelectrolytes. First, poly(γ-glutamic acid)-g-3-aminophenylboronic acid) (γ-PGA-g-APBA) and galactosylated chitosan oligosaccharide (GC) were synthesized by grafting APBA and lactobionic acid (LA) to γ-PGA and CS, respectively. The (γ-PGA-g-APBA/GC)5 capsules were then prepared by layer-by-layer (LBL) assembly of γ-PGA-g-APBA and GC via electrostatic interaction. The size and morphology of the particles and capsules were investigated by DLS, SEM, and TEM. The size of the (γ-PGA-g-APBA/GC)5 capsules increased with increasing glucose concentration due to the swelling of the capsules. The capsules could be dissociated at high glucose concentration due to the breaking of the cross-linking bonds between APBA and LA by the competitive reaction of APBA with glucose. The encapsulated insulin was able to undergo self-regulated release from the capsules depending on the glucose level and APBA composition. The amount of insulin release increased with incubation in higher glucose concentration and decreased with higher APBA composition. Moreover, the on-off regulation of insulin release from the (γ-PGA-g-APBA/GC)5 capsules could be triggered with a synchronizing and variation of the external glucose concentration, whereas the capsules without the LA functional groups did not show the on-off regulated release. Furthermore, the (γ-PGA-g-APBA/GC)5 capsules are biocompatible. These (γ-PGA-g-APBA/GC)5 with good stability, glucose response, and controlled insulin delivery are expected to be used for future applications to glucose-triggered insulin delivery. PMID:27210795

  5. Liquid-core nanocellulose-shell capsules with tunable oxygen permeability.

    Science.gov (United States)

    Svagan, A J; Bender Koch, C; Hedenqvist, M S; Nilsson, F; Glasser, G; Baluschev, S; Andersen, M L

    2016-01-20

    Encapsulation of oxygen sensitive components is important in several areas, including those in the food and pharmaceutical sectors, in order to improve shelf-life (oxidation resistance). Neat nanocellulose films demonstrate outstanding oxygen barrier properties, and thus nanocellulose-based capsules are interesting from the perspective of enhanced protection from oxygen. Herein, two types of nanocellulose-based capsules with liquid hexadecane cores were successfully prepared; a primary nanocellulose polyurea-urethane capsule (diameter: 1.66 μm) and a bigger aggregate capsule (diameter: 8.3 μm) containing several primary capsules in a nanocellulose matrix. To quantify oxygen permeation through the capsule walls, an oxygen-sensitive spin probe was dissolved within the liquid hexadecane core, allowing non-invasive measurements (spin-probe oximetry, electron spin resonance, ESR) of the oxygen concentration within the core. It was observed that the oxygen uptake rate was significantly reduced for both capsule types compared to a neat hexadecane solution containing the spin-probe, i.e. the slope of the non-steady state part of the ESR-curve was approximately one-third and one-ninth for the primary nanocellulose capsule and aggregated capsule, respectively, compared to that for the hexadecane sample. The transport of oxygen was modeled mathematically and by fitting to the experimental data, the oxygen diffusion coefficients of the capsule wall was determined. These values were, however, lower than expected and one plausible reason for this was that the ESR-technique underestimate the true oxygen uptake rate in the present systems at non-steady conditions, when the overall diffusion of oxygen was very slow. PMID:26572358

  6. Engineering an iridium-containing metal-organic molecular capsule for induced-fit geometrical conversion and dual catalysis.

    Science.gov (United States)

    Li, Xuezhao; Wu, Jinguo; Chen, Liyong; Zhong, Xiaoming; He, Cheng; Zhang, Rong; Duan, Chunying

    2016-08-11

    By introducing photoactive fac-tris(2-phenylpyridine)iridium moieties as a ligand backbone to constrain the coordination geometry of cobalt ions, a multifunctional Ir2Co3-type capsule was achieved and showed induced-fit capsule-capsule conversion by cooperative binding one carbonate anion with the equatorial Co(ii) centers. The capsule combined photocatalysis and transition metal activation synergistically and exhibited efficient catalytic ability on visible light-activated α-trichloromethylation. PMID:27320443

  7. Inadvertent Trypan Blue Staining of Posterior Capsule during Cataract Surgery Associated with “Argentinian Flag” Event

    OpenAIRE

    Prinzi, Robert A.; Alapati, Neeti M.; Gappy, Shawn S.; Dilly, Jason S.

    2016-01-01

    Trypan blue is common in visualizing the anterior capsule during cataract surgery. Inadvertent staining of the posterior capsule during phacoemulsification is a rare complication and there are few reports in the literature. The proposed mechanism of posterior capsule staining in previous reports includes a compromised zonular apparatus or iris retractors facilitating the posterior flow of trypan blue. We report the first case of trypan blue staining of the posterior capsule associated with th...

  8. The Contrast of Chinese and English in the Translation of Chinese Poetry

    OpenAIRE

    Ning Li

    2009-01-01

    Chinese poetry is the soul of Chinese literature and Chinese culture. A good translation of a Chinese verse can promote the prevalence of Chinese culture. In the translation of Chinese poetry, translators should not only keep the characteristics of Chinese poems, but also embody the English characteristics. This article analyzed some versions of translation and proposed factors affecting the translation of Chinese poetry.

  9. 改良荚膜肿胀试验%Modified capsule quellung test

    Institute of Scientific and Technical Information of China (English)

    谢水祥; 马廉兰; 刘志春

    2007-01-01

    m,大于对照组2[(0.215±0.022),(0.247±0.018),(0.213±0.033),(0.220±0.016)μm,P<0.01].③对照组2荚膜厚度小于对照组1(P<0.01),实验组2荚膜厚度小于实验组1(P<0.01).结论:作为一种定量试验,改良荚膜肿胀试验比传统荚膜肿胀试验更为稳定与准确.%BACKGROUND: Studies have confirmed that there is secreted protein out of cell wall of Candida albicans. However, in recent researches, we found there may be a capsule-like-structure within it.OBJECTIVE: To observe the capsule-like structure of Candida albicans by means of modified quellung test.DESIGN: A controlled observation experiment.SETTING: Department of Medical Microbiology, Gannan Medical College.MATERIALS: Candida albicans from 2 clinical specimens (C1, C2) identified by preserve center of Epiphyte strains of Chinese Academy of Science (Nanjing, China) and standard strains (CCCMC1a and ATCC14053) donated by preserve center of Epiphyte strains of Peking University (Beijing, China) were taken to quellung test. Experimental rabbits (weighing 2-2.5 kg) for preparing normal serum and antiserum were donated by Experimental Animal Center of Sun Yat-sen University. Antiserum was prepared by the book with experimental strains (C1, C2, CCCMC1a, and ATCC)respectively for later quellung tests.METHODS: This experiment was carried out in the Department of Medical Microbiology, Gannan Medical College in December 2005. ① Traditional Quellung test: The culture of Candida albicans (C1, C2, CCCMC1a, and ATCC) was spread on a slide respectively. Corresponding rabbit antiserum was added onto the slide (experimental group 1) and normal serum was added onto the slide (control group1). 1% methylene blue was added into each group, and then the slides were placed in a wet box at 37 ℃ for 20 minutes; the slides were taken out and covered with a cover-slip. Under the oil immersion, the count of Candida albicans was taken and the microscopic surveying instrument was used to measure the capsule thickness

  10. The measurement of capsule heat transfer gaps using neutron radiography.

    Science.gov (United States)

    Thaler, L. A.

    1971-01-01

    The use of neutron radiographs to determine dimensional changes of heat transfer gaps in cylindrical nuclear fueled capsules is described. A method was developed which involves scanning a very fine grained neutron radiograph negative with a recording microdensitometer. The output of the densitometer is recorded on graph paper and the heat transfer gap is plotted as a well-defined optical density change. Calibration of the recording microdensitometer ratio arms permits measurements to be made of the heat transfer optical density change from the microdensitometer trace. Total heat transfer gaps, measured by this method, agree with the physical measurements within plus or minus 0.005 cm over a range of gaps from 0.061 to 0.178 cm.

  11. [Glomus tumor of volar elbow capsule. Case report].

    Science.gov (United States)

    Burnier, M; Erhard, L

    2014-02-01

    Glomus tumors are rare tumors, benign but painful and responsible for a major functional impairment. Although their preferential localization is digital, 35% of glomus tumors are extradigital. Ignorance of this disease characterized by atypical clinical signs and the absence of specific imaging are responsible for a significant diagnostic delay, 7 to 10 years in extradigital forms. Treatment by surgical excision simply ensures immediate disappearance of pain without recurrence in 90% of cases. It is therefore necessary to emphasize the existence of this sometimes debilitating condition benefiting from effective therapeutic solution. We report the case of a glomus tumor of the anterior capsule of the left elbow in a 24-year-old woman with a diagnostic delayed by 12 years. PMID:24394237

  12. Multilayer Films and Capsules of Sodium Carboxymethylcellulose and Polyhexamethylenguanidine Hydrochloride

    Science.gov (United States)

    Guzenko, Nataliia; Gabchak, Oleksandra; Pakhlov, Evgenij

    The complexation of polyhexamethylenguanidine hydrochloride (PHMG) and sodium carboxymethylcellulose (CMC) was investigated for different conditions. Mixing of equiconcentrated aqueous solutions of the polyelectrolytes was found to result in the formation of an insoluble interpolyelectrolyte complex with an overweight of carboxymethylcellulose. A step-by-step formation of stable, irreversibly adsorbed multilayer film of the polymers was demonstrated using the quartz crystal microbalance method. Unusually thick polymer shells with a large number of loops and tails of the polyanion were formed by the method of layer-by-layer self-assembly of PHMG and CMC on spherical CaCO3 particles. Hollow multilayer capsules stable in neutral media were obtained by dissolution of the inorganic matrix in EDTA solution.

  13. Pre- and postirradiation evaluation of fuel in capsule HRB-14

    International Nuclear Information System (INIS)

    Capsule HRB-14 was irradiated jointly by Oak Ridge National Laboratory and General Atomic Company (GA). This report covers the pre- and postirradiation characterization and evaluation of the GA fuel. The experiment was primarily to characterize the irradiation performance of TRISO-coated low-enriched (Th,U)O2, UC07O05, and UO2 particles and TRISO ThO2 particles. Twenty cured-in-place fuel rods containing the fuel particles were irradiated at 9600 to 11300C. The fluence was 4.5 to 8.3 x 1025 n/m2 (E > 29 fJ)/sub HTGR/. The fertile burnup was 4.1% to 8.5% fissions per initial metal atom (FIMA); the mixed oxide burnup was 14.5% to 19.3% FIMA; the uranium fissile burnup was 27.9% to 29.5% FIMA

  14. An ingestible, NIR-fluorometric, cancer-screening capsule.

    Science.gov (United States)

    Demosthenous, Panayiota; Georgiou, Julius

    2015-08-01

    Asymptomatic, early-stage, cancer detection is a problem in the small intestine, that is largely inaccessible. This paper presents a cost-effective screening capsule prototype, which is able to detect infrared (IR) fluorescence emitted by indocyanine green (ICG) fluorophore dye. The presented mixed-signal system has a small size, consumes little power and works as a high-sensitivity fluorometer that records fluorescence levels throughout the small intestine, rather than collecting images that need labour intensive video analysis. Ex-vivo experiments, on ICG-impregnated swine intestine, have shown that the prototype system is able to detect low concentrations of ICG in the nanomolar and micromolar region, which is required to detect early cancer in the small intestine. PMID:26736713

  15. Production and quality assurance of I-131 capsules

    International Nuclear Information System (INIS)

    The Radiochemistry Department produces two radioactive products for human use: 131I-Sodium Iodide as a solution and as capsules dosage forms which are used for the diagnosis and treatment of various thyroid disorders including toxic nodules, thyroid hypofunction, carcinoma of the thyroid gland and hyperthyroidism, for nearly 50 years. As such, the Radiochemistry Department is considered as a 'mini' pharmaceutical enterprise, and therefore has to obey, under law, the rules of the Israeli ministry of Health. GMP requirements have been implemented in all our production and packaging units. A computerized system which is now an integral part of the whole process, starting from the stage of requested orders and ending with delivery to the hospitals, was developed and its features are presented here along with quality assurance policy. (author)

  16. Three-dimensional image reconstruction in capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    Anastasios Koulaouzidis; Alexandros Karargyris

    2012-01-01

    To date,limited research has been carried out in developing methods and materials that offer three-dimensional (3-D) representation of the digestive tract.In the field of capsule endoscopy (CE),hardware approaches have been developed that provide real time both 3-D information and texture using an infrared projector and a complementary metal oxide semiconductor camera.The major drawbacks of this system are its size,power consumption and packaging issues.A software approach to approximate a 3-D representation of digestive tract surface utilising current CE technology has been proposed.The algorithm utilizes the Shape from Shading technique and seem to provide promising results for polypoid structures and angioectasias.Further clinical evaluation is currently under way.

  17. Advantages of Catalysis in Self-Assembled Molecular Capsules.

    Science.gov (United States)

    Catti, Lorenzo; Zhang, Qi; Tiefenbacher, Konrad

    2016-06-27

    Control over the local chemical environment of a molecule can be achieved by encapsulation in supramolecular host systems. In supramolecular catalysis, this control is used to gain advantages over classical homogeneous catalysis in bulk solution. Two of the main advantages concern influencing reactions in terms of substrate and product selectivity. Due to size and/or shape recognition, substrate selective conversion can be realized. Additionally, noncovalent interactions with the host environment facilitate alternative reaction pathways and can yield unusual products. This Concept article discusses and highlights literature examples utilizing self-assembled molecular capsules to achieve catalytic transformations displaying a high degree of substrate and/or product selectivity. Furthermore, the advantage of supramolecular hosts in multicatalyst tandem reactions is covered. PMID:27150251

  18. Structural damage in thin SLIM-Cut c-Si foils fabricated for solar cell purposes: atomic assessment by electron spin resonance

    International Nuclear Information System (INIS)

    Within the context of reducing production costs, thin (<90 μm) silicon foils intended for photovoltaic applications have been fabricated from standard (100)Si wafers using a low-temperature (<150 °C) stress-induced lift-off process. A multi-frequency electron spin resonance (ESR) study was performed in order to evaluate, at atomic scale, the quality of the material in terms of defects, including identification and quantification. Generally, a complex ESR spectrum is observed, disentangled as the superposition of three separate signals. This includes, most prominently (∼91% of total density) the D-line (Si3 ≡ Si· dangling bonds in a disordered Si environment), a set (∼6%) of highly anisotropic signals ascribed to dislocations (K1-like), and a triplet, identified as the Si-SL5 N-donor defect. Defect density depth profiling from the lift-off side shows all signals disappear in tandem after etching off a ∼33 μm thick Si layer, indicating a highly correlated−equal in relative terms−distribution of the three types of defects over the affected top part of the Si foil. The defect density is found to be highly non-uniform laterally, with the density peaking near the crack initiation point, from which defect generation spreads. It is thus found that the SLIM-Cut method for fabrication of thin Si foils results in the introduction of defects that would unacceptably impair the functionality of photovoltaic cells built on these substrates. Fortunately, this may be cured by etching off a thin top Si layer, resulting in a most useful thin Si foil of standard high quality. (paper)

  19. Generation of colloidal granules and capsules from double emulsion drops

    Science.gov (United States)

    Hess, Kathryn S.

    Assemblies of colloidal particles are extensively used in ceramic processing, pharmaceuticals, inks and coatings. In this project, the aim was to develop a new technique to fabricate monodispersed colloidal assemblies. The use of microfluidic devices and emulsion processing allows for the fabrication of complex materials that can be used in a variety of applications. A microfluidic device is used to create monodispersed water/oil/water (w/o/w) double emulsions with interior droplets of colloidal silica suspension ranging in size from tens to hundreds of microns. By tailoring the osmotic pressure using glycerol as a solute in the continuous and inner phases of the emulsion, we can control the final volume size of the monodispersed silica colloidal crystals that form in the inner droplets of the double emulsion. Modifying the ionic strength in the colloidal dispersion can be used to affect the particle-particle interactions and crystal formation of the final colloidal particle. This w/o/w technique has been used with other systems of metal oxide colloids and cellulose nanocrystals. Encapsulation of the colloidal suspension in a polymer shell for the generation of ceramic-polymer core-shell particles has also been developed. These core-shell particles have spawned new research in the field of locally resonant acoustic metamaterials. Systems and chemistries for creating cellulose hydrogels within the double emulsions have also been researched. Water in oil single emulsions and double emulsions have been used to create cellulose hydrogel spheres in the sub-100 micron diameter range. Oil/water/oil double emulsions allow us to create stable cellulose capsules. The addition of a second hydrogel polymer, such as acrylate or alginate, further strengthens the cellulose gel network and can also be processed into capsules and particles using the microfluidic device. This work could have promising applications in acoustic metamaterials, personal care products, pharmaceuticals

  20. Analysis of Wireless Capsule Endoscopy Images using Local Binary Patterns

    Directory of Open Access Journals (Sweden)

    Adriana Florentina CONSTANTINESCU

    2015-06-01

    Full Text Available Wireless capsule endoscopy, the gold standard in the screening and diagnosis of small bowel diseases, is one of the most recent investigations for gastrointestinal pathology. This examination has the advantages of being non-invasive, painless, with a large clinical yield, especially for small bowel diseases, but also some disadvantages. The long time necessary for reading and interpreting all frames acquired is one of these disadvantages. This inconvenient could be improved through different methods by using software applications. In this study we have used a software application for texture analysis based on local binary pattern (LBP operator. This operator detects and removes non-informative frames in a first step, then identifies potential lesions. Our study group consisted of 33 patients from the Gastroenterology and Hepatology Centre Craiova and from the 1st Internal Medicine and Gastroenterology Clinic from the Emergency County Hospital of Craiova. The patients included in the study have corresponded to our inclusion criteria established. The exclusion criteria were represented by the contraindications of the capsule endoscopy. In the first phase of the study, we have removed the non-informative frames from the original videos obtained, and we have acquired an average reduction of 6.96% from the total number of images. In the second phase, using the same LBP operator, we have correctly identified 93.16% of telangiectasia lesions. Our study demonstrated that software applications based on LBP operator can lead to a shorter analysis time, by reducing the overall frames number, and can also provide support in diagnosis.