WorldWideScience

Sample records for chest high-field magnetic

  1. Lung disease assessment in primary ciliary dyskinesia: a comparison between chest high-field magnetic resonance imaging and high-resolution computed tomography findings

    Directory of Open Access Journals (Sweden)

    Iacotucci Paola

    2009-08-01

    Full Text Available Abstract Background Primary ciliary dyskinesia (PCD is associated with pulmonary involvement that requires periodical assessment. Chest high-resolution computed tomography (HRCT has become the method of choice to evaluate chronic lung disease, but entails exposure to ionizing radiation. Magnetic resonance imaging (MRI has been proposed as a potential radiation-free technique in several chest disorders. Aim of our study is to evaluate whether high-field MRI is as effective as HRCT in identifying PCD pulmonary abnormalities. We also analyzed the relationships between the severity and extension of lung disease, and functional data. Methods Thirteen PCD patients (8 children/5 adults; median age, 15.2 yrs underwent chest HRCT and high-field 3T MRI, spirometry, and deep throat or sputum culture. Images were scored using a modified version of the Helbich system. Results HRCT and MRI total scores were 12 (range, 6–20 and 12 (range, 5–17, respectively. Agreement between HRCT and MRI scores was good or excellent (r > 0.8. HRCT and MRI total scores were significantly related to forced vital capacity (r = -0.5, p = 0.05; and r = -0.7, p = 0.009, respectively and forced expiratory volume at 1 second (r = -0.6, p = 0.03; and r = -0.7, p = 0.009, respectively. Conclusion Chest high-field 3T MRI appears to be as effective as HRCT in assessing the extent and severity of lung abnormalities in PCD. MRI scores might be used for longitudinal assessment and be an outcome surrogate in future studies.

  2. High field superconducting magnets

    Science.gov (United States)

    Hait, Thomas P. (Inventor); Shirron, Peter J. (Inventor)

    2011-01-01

    A superconducting magnet includes an insulating layer disposed about the surface of a mandrel; a superconducting wire wound in adjacent turns about the mandrel to form the superconducting magnet, wherein the superconducting wire is in thermal communication with the mandrel, and the superconducting magnet has a field-to-current ratio equal to or greater than 1.1 Tesla per Ampere; a thermally conductive potting material configured to fill interstices between the adjacent turns, wherein the thermally conductive potting material and the superconducting wire provide a path for dissipation of heat; and a voltage limiting device disposed across each end of the superconducting wire, wherein the voltage limiting device is configured to prevent a voltage excursion across the superconducting wire during quench of the superconducting magnet.

  3. High-field magnetization in transuranium compound

    Energy Technology Data Exchange (ETDEWEB)

    Sugiyama, K. [Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan) and KYOKUGEN, Osaka University, Osaka 560-8531 (Japan)]. E-mail: sugiyama@phys.sci.osaka-u.ac.jp; Nakashima, H. [Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Aoki, D. [Institute of Material Research, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Ikeda, S. [Institute of Material Research, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Haga, Y. [Advanced Science and Research Centerer, JAEA, Tokai, Ibaraki 319-1195 (Japan); Yamamoto, E. [Advanced Science and Research Centerer, JAEA, Tokai, Ibaraki 319-1195 (Japan); Nakamura, A. [Advanced Science and Research Centerer, JAEA, Tokai, Ibaraki 319-1195 (Japan); Homma, Y. [Institute of Material Research, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Shiokawa, Y. [Institute of Material Research, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Kindo, K. [Institite of Solid State Physics, University of Tokyo, Kashiwanoha 5-1-5, Kashiwa, Chiba 277-8581 (Japan); Hagiwara, M. [KYOKUGEN, Osaka University, Osaka 560-8531 (Japan); Onuki, Y. [Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Advanced Science and Research Centerer, JAEA, Tokai, Ibaraki 319-1195 (Japan)

    2007-03-15

    We measured the high-field magnetization up to 55T and constructed a magnetic phase diagram for a transuranium antiferromagnet NpRhGa{sub 5} with the tetragonal structure. The magnetization at 4.2K for H(parallel) [100] indicates a sharp metamagnetic transition with a step at H{sub c}=26T and saturates above H{sub s}=38T, reaching 0.43{mu}{sub B}/Np. An ordered moment of 0.96{mu}{sub B}/Np at zero field, which was determined from the neutron scattering experiment, is found to be reduced to 0.43{mu}{sub B}/Np at H{sub s}, together with an orientation of the magnetic moment from the (001) plane to the (100) plane.

  4. High Field Pulse Magnets with New Materials

    Science.gov (United States)

    Li, L.; Lesch, B.; Cochran, V. G.; Eyssa, Y.; Tozer, S.; Mielke, C. H.; Rickel, D.; van Sciver, S. W.; Schneider-Muntau, H. J.

    2004-11-01

    High performance pulse magnets using the combination of CuNb conductor and Zylon fiber composite reinforcement with bore sizes of 24, 15 and 10 mm have been designed, manufactured and tested to destruction. The magnets successfully reached the peak fields of 64, 70 and 77.8 T respectively with no destruction. Failures occurred near the end flanges at the layer. The magnet design, manufacturing and testing, and the mode of the failure are described and analyzed.

  5. High Field Magnetization of Tb Single Crystals

    DEFF Research Database (Denmark)

    Roeland, L. W.; Cock, G. J.; Lindgård, Per-Anker

    1975-01-01

    The magnetization of Tb single crystals was measured in magnetic fields to 34T along the hard direction at temperature of 1.8, 4.2, 65.5 and 77K, and along with easy direction at 4.2 and 77K. The data are compared with the results of a self-consistent spin wave calculation using a phenomenological...

  6. High-Field Superconducting Magnets Supporting PTOLEMY

    Science.gov (United States)

    Hopkins, Ann; Luo, Audrey; Osherson, Benjamin; Gentile, Charles; Tully, Chris; Cohen, Adam

    2013-10-01

    The Princeton Tritium Observatory for Light, Early Universe, Massive Neutrino Yield (PTOLEMY) is an experiment planned to collect data on Big Bang relic neutrinos, which are predicted to be amongst the oldest and smallest particles in the universe. Currently, a proof-of-principle prototype is being developed at Princeton Plasma Physics Laboratory to test key technologies associated with the experiment. A prominent technology in the experiment is the Magnetic Adiabatic Collimation with an Electrostatic Filter (MAC-E filter), which guides tritium betas along magnetic field lines generated by superconducting magnets while deflecting those of lower energies. B field mapping is performed to ensure the magnets produce a minimum field at the midpoint of the configuration of the magnets and to verify accuracy of existing models. Preliminary tests indicate the required rapid decrease in B field strength from the bore of the more powerful 3.35 T magnet, with the field dropping to 0.18 T approximately 0.5 feet from the outermost surface of the magnet.

  7. High-Field Accelerator Magnets Beyond LHC

    CERN Document Server

    Devred, Arnaud

    2003-01-01

    The LHC magnet R&D Program has shown that the limit of NbTi technology at 1.8 K was in the range 10 to 10.5 T. Hence, to go beyond the 10-T threshold, it is necessary to change of superconducting material. Given the state of the art in HTS, the only serious candidate is Nb3Sn. A series of dipole magnet models built at Twente University and LBNL and a vigorous program underway at FNAL have demonstrated the feasibility of Nb3Sn magnet technology. The next step is to bring this technology to maturity, which requires further conductor and conductor insulation development and a simplification of manufacturing processes. After outlining a roadmap to address outstanding issues, we evoke the US proposal for a second generation of LHC Insertion Region (IR) magnets and the Next European Dipole (NED) initiative promoted by the European Steering Group on Accelerator R&D (ESGARD).

  8. Ultra-high-field superconducting magnets

    Energy Technology Data Exchange (ETDEWEB)

    Hoard, R.W.; Cornish, D.N.; Scanlan, R.M.; Zbasnik, J.P.; Leber, R.L.; Hickman, R.B.; Lee, J.D.

    1983-08-01

    The following topics are considered: (1) superfluid helium for advanced magnets, (2) conductor reinforcement, (3) designing a 20-T, 2-m bore solenoidal coil, (4) coil size and conductor properties, (5) axial forces on the coil, (6) effect of radiation on the coil systems, and (7) helium-II transient heat transfer and coil protection. (MOW)

  9. High-temperature superconductors in high-field magnets

    NARCIS (Netherlands)

    Weijers, Hubertus Wilhelmus

    2009-01-01

    The properties of both BSCCO conductors and YBCO coated conductors and coils are studied to assess their applicability in high-field magnets. First, the magnetic field dependence of the critical current density in these HTS conductors is measured at 4.2 K in magnetic field conditions ranging from s

  10. On the origin of high-field magnetic white dwarfs

    CERN Document Server

    García-Berro, E; Lorén-Aguilar, P; Aznar-Siguán, G; Camacho, J; Külebi, B; Isern, J; Althaus, L G; Córsico, A H

    2012-01-01

    High-field magnetic white dwarfs have been long suspected to be the result of stellar mergers. However, the nature of the coalescing stars and the precise mechanism that produces the magnetic field are still unknown. Here we show that the hot, convective, differentially rotating corona present in the outer layers of the remnant of the merger of two degenerate cores is able to produce magnetic fields of the required strength that do not decay for long timescales. We also show, using an state-of-the-art Monte Carlo simulator, that the expected number of high-field magnetic white dwarfs produced in this way is consistent with that found in the solar neighborhood.

  11. High-field magnetization of dilute rare earths in yttrium

    DEFF Research Database (Denmark)

    Touborg, P.; Høg, J.; Cock, G. J.;

    1974-01-01

    Magnetization measurements have been performed on single crystals of Y containing small amounts of Tb, Dy, or Er at 4.2 K in fields up to 295 × 105 A/m (370 kOe). Crystal-field and molecular-field parameters obtained from measurements of the initial susceptibility versus temperature give...... a satisfactory quantitative account of the high-field magnetization. This includes characteristic features due to the crossing and mixing of crystal-field levels....

  12. High-field Magnet Development toward the High Luminosity LHC

    Energy Technology Data Exchange (ETDEWEB)

    Apollinari, Giorgio [Fermilab

    2014-07-01

    The upcoming Luminosity upgrade of the LHC (HL-LHC) will rely on the use of Accelerator Quality Nb3Sn Magnets which have been the focus of an intense R&D effort in the last decade. This contribution will describe the R&D and results of Nb3Sn Accelerator Quality High Field Magnets development efforts, with emphasis on the activities considered for the HL-LHC upgrades.

  13. Survey of high field superconducting material for accelerator magnets

    Energy Technology Data Exchange (ETDEWEB)

    Scahlan, R.; Greene, A.F.; Suenaga, M.

    1986-05-01

    The high field superconductors which could be used in accelerator dipole magnets are surveyed, ranking these candidates with respect to ease of fabrication and cost as well as superconducting properties. Emphasis is on Nb/sub 3/Sn and NbTi. 27 refs., 2 figs. (LEW)

  14. Homogenous BSCCO-2212 Round Wires for Very High Field Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Scott Campbell

    2012-06-30

    The performance demands on modern particle accelerators generate a relentless push towards higher field magnets. In turn, advanced high field magnet development places increased demands on superconducting materials. Nb3Sn conductors have been used to achieve 16 T in a prototype dipole magnet and are thought to have the capability for {approx}18 T for accelerator magnets (primarily dipoles but also higher order multipole magnets). However there have been suggestions and proposals for such magnets higher than 20 T. The High Energy Physics Community (HEP) has identified important new physics opportunities that are enabled by extremely high field magnets: 20 to 50 T solenoids for muon cooling in a muon collider (impact: understanding of neutrinos and dark matter); and 20+ T dipoles and quadrupoles for high energy hadron colliders (impact: discovery reach far beyond present). This proposal addresses the latest SBIR solicitation that calls for grant applications that seek to develop new or improved superconducting wire technologies for magnets that operate at a minimum of 12 Tesla (T) field, with increases up to 15 to 20 T sought in the near future (three to five years). The long-term development of accelerator magnets with fields greater than 20 T will require superconducting wires having significantly better high-field properties than those possessed by current Nb{sub 3}Sn or other A15 based wires. Given the existing materials science base for Bi-2212 wire processing, we believe that Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub y} (Bi-2212) round wires can be produced in km-long piece lengths with properties suitable to meet both the near term and long term needs of the HEP community. The key advance will be the translation of this materials science base into a robust, high-yield wire technology. While the processing and application of A15 materials have advanced to a much higher level than those of the copper oxide-based, high T{sub c} (HTS) counterparts, the HTS materials have

  15. Chest magnetic resonance imaging: a protocol suggestion

    Directory of Open Access Journals (Sweden)

    Bruno Hochhegger

    2015-12-01

    Full Text Available Abstract In the recent years, with the development of ultrafast sequences, magnetic resonance imaging (MRI has been established as a valuable diagnostic modality in body imaging. Because of improvements in speed and image quality, MRI is now ready for routine clinical use also in the study of pulmonary diseases. The main advantage of MRI of the lungs is its unique combination of morphological and functional assessment in a single imaging session. In this article, the authors review most technical aspects and suggest a protocol for performing chest MRI. The authors also describe the three major clinical indications for MRI of the lungs: staging of lung tumors; evaluation of pulmonary vascular diseases; and investigation of pulmonary abnormalities in patients who should not be exposed to radiation.

  16. Chest magnetic resonance imaging: a protocol suggestion*

    Science.gov (United States)

    Hochhegger, Bruno; de Souza, Vinícius Valério Silveira; Marchiori, Edson; Irion, Klaus Loureiro; Souza Jr., Arthur Soares; Elias Junior, Jorge; Rodrigues, Rosana Souza; Barreto, Miriam Menna; Escuissato, Dante Luiz; Mançano, Alexandre Dias; Araujo Neto, César Augusto; Guimarães, Marcos Duarte; Nin, Carlos Schuler; Santos, Marcel Koenigkam; Silva, Jorge Luiz Pereira e

    2015-01-01

    In the recent years, with the development of ultrafast sequences, magnetic resonance imaging (MRI) has been established as a valuable diagnostic modality in body imaging. Because of improvements in speed and image quality, MRI is now ready for routine clinical use also in the study of pulmonary diseases. The main advantage of MRI of the lungs is its unique combination of morphological and functional assessment in a single imaging session. In this article, the authors review most technical aspects and suggest a protocol for performing chest MRI. The authors also describe the three major clinical indications for MRI of the lungs: staging of lung tumors; evaluation of pulmonary vascular diseases; and investigation of pulmonary abnormalities in patients who should not be exposed to radiation. PMID:26811555

  17. Homogenous BSCCO-2212 Round Wires for Very High Field Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Scott Campbell

    2012-06-30

    The performance demands on modern particle accelerators generate a relentless push towards higher field magnets. In turn, advanced high field magnet development places increased demands on superconducting materials. Nb3Sn conductors have been used to achieve 16 T in a prototype dipole magnet and are thought to have the capability for {approx}18 T for accelerator magnets (primarily dipoles but also higher order multipole magnets). However there have been suggestions and proposals for such magnets higher than 20 T. The High Energy Physics Community (HEP) has identified important new physics opportunities that are enabled by extremely high field magnets: 20 to 50 T solenoids for muon cooling in a muon collider (impact: understanding of neutrinos and dark matter); and 20+ T dipoles and quadrupoles for high energy hadron colliders (impact: discovery reach far beyond present). This proposal addresses the latest SBIR solicitation that calls for grant applications that seek to develop new or improved superconducting wire technologies for magnets that operate at a minimum of 12 Tesla (T) field, with increases up to 15 to 20 T sought in the near future (three to five years). The long-term development of accelerator magnets with fields greater than 20 T will require superconducting wires having significantly better high-field properties than those possessed by current Nb{sub 3}Sn or other A15 based wires. Given the existing materials science base for Bi-2212 wire processing, we believe that Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub y} (Bi-2212) round wires can be produced in km-long piece lengths with properties suitable to meet both the near term and long term needs of the HEP community. The key advance will be the translation of this materials science base into a robust, high-yield wire technology. While the processing and application of A15 materials have advanced to a much higher level than those of the copper oxide-based, high T{sub c} (HTS) counterparts, the HTS materials have

  18. Micromagnetic simulation for high field sensors with perpendicular magnetizations

    Institute of Scientific and Technical Information of China (English)

    Jin Wei; Liu Yao-Wen

    2007-01-01

    In this paper, we present a micromagnetic design for high field sensors. The hard layer of the sensors is L10-FePt which is magnetized perpendicularly to film plane and the sense layer is NiFe which is magnetized in the film plane. The magnetization configurations of the hard and sense layers at different external magnetic fields have been simulated. In micromagnetic simulation, the sense field up to one tesla can be reached by using this sensor. We find that whether the sensor has a symmetric or an asymmetric field-sensing window is determined by the coercive field of the hard layer and the demagnetizing field of the sense layer.

  19. Magnetic resonance imaging and spectroscopy at ultra high fields

    Energy Technology Data Exchange (ETDEWEB)

    Neuberger, Thomas

    2009-06-23

    The goal of the work presented in this thesis was to explore the possibilities and limitations of MRI / MRS using an ultra high field of 17.6 tesla. A broad range of specific applications and MR methods, from MRI to MRSI and MRS were investigated. The main foci were on sodium magnetic resonance spectroscopic imaging of rodents, magnetic resonance spectroscopy of the mouse brain, and the detection of small amounts of iron labeled stem cells in the rat brain using MRI Sodium spectroscopic imaging was explored since it benefits tremendously from the high magnetic field. Due to the intrinsically low signal in vivo, originating from the low concentrations and short transverse relaxation times, only limited results have been achieved by other researchers until now. Results in the literature include studies conducted on large animals such as dogs to animals as small as rats. No studies performed on mice have been reported, despite the fact that the mouse is the most important laboratory animal due to the ready availability of transgenic strains. Hence, this study concentrated on sodium MRSI of small rodents, mostly mice (brain, heart, and kidney), and in the case of the brain on young rats. The second part of this work concentrated on proton magnetic resonance spectroscopy of the rodent brain. Due to the high magnetic field strength not only the increasing signal but also the extended spectral resolution was advantageous for such kind of studies. The difficulties/limitations of ultra high field MRS were also investigated. In the last part of the presented work detection limits of iron labeled stem cells in vivo using magnetic resonance imaging were explored. The studies provided very useful benchmarks for future researchers in terms of the number of labeled stem cells that are required for high-field MRI studies. Overall this work has shown many of the benefits and the areas that need special attention of ultra high fields in MR. Three topics in MRI, MRS and MRSI were

  20. Ultra-high field magnets for whole-body MRI

    Science.gov (United States)

    Warner, Rory

    2016-09-01

    For whole-body MRI, an ultra-high field (UHF) magnet is currently defined as a system operating at 7 T or above. Over 70 UHF magnets have been built, all with the same technical approach originally developed by Magnex Scientific Ltd. The preferred coil configuration is a compensated solenoid. In this case, the majority of the field is generated by a simple long solenoid that stretches the entire length of the magnet. Additional coils are wound on a separate former outside the main windings with the purpose of balancing the homogeneity. Most of the magnets currently in operation are passively shielded systems where the magnet is surrounded by a steel box of 200-870 tonnes of carbon steel. More recently actively shielded magnets have been built for operation at 7 T; in this case the stray field is controlled by with reverse turns wound on a separate former outside the primary coils. Protection against quench damage is much more complex with an actively shielded magnet design due to the requirement to prevent the stray field from increasing during a quench. In the case of the 7 T 900 magnet this controlled by combining some of the screening coils into each section of the protection circuit. Correction of the field variations caused by manufacturing tolerances and environmental effects are made with a combination of superconducting shims and passive shims. Modern UHF magnets operate in zero boil-off mode with the use of cryocoolers with cooling capacity at 4.2 K. Although there are no cryogen costs associated with normal operation UHF magnets require a significant volume (10 000-20 000 l) of liquid helium for the cool-down. Liquid helium is expensive therefore new methods of cool-down using high-power cryocoolers are being implemented to reduce the requirement.

  1. Developments at the High Field Magnet Laboratory in Nijmegen

    Science.gov (United States)

    Perenboom, J. A. A. J.; Maan, J. C.; van Breukelen, M. R.; Wiegers, S. A. J.; den Ouden, A.; Wulffers, C. A.; van der Zande, W. J.; Jongma, R. T.; van der Meer, A. F. G.; Redlich, B.

    2013-03-01

    The High Field Magnet Laboratory at the Radboud University Nijmegen is rapidly expanding its capabilities. The developments encompass both organizational changes and new possibilities for research. The organization of the HFML was strengthened as a consequence of stronger participation of the Foundation for Fundamental Research on Matter (FOM), and an increase of the core-funding. This change makes that HFML is now considered on a national level as large research facility that operates at an international scale. At the same time work is underway to build new and powerful magnets, and provide electromagnetic radiation for magneto-spectroscopic studies. Electromagnetic radiation in the infrared and far-infrared spectrum will soon be available in the HFML with wavelengths between 3 μm and 1.5 mm, produced by the `FELIX' facility, comprising the long-wavelength free electron laser `FLARE' that in September 2011 produced its first light and the free electron lasers that have been moved from Rijnhuizen to Nijmegen. In magnet technology great strides are made to make magnets available for the user community with unprecedented performance: late in 2012 we hope to commission a new all-resistive magnet system that will generate a steady magnetic field as high as 38 T, by fully exploiting the maximum power of the installation, i.e. 20 MW, and using all available improvements in the design and construction of `Florida-Bitter' resistive magnets. We are also well underway with the design of a 45 T hybrid magnet system, using Nb3Sn superconductors and wind-and-react Cable-in-Conduit technology.

  2. Magnet Science and Technology for Basic Research at the High Field Laboratory for Superconducting Materials

    Institute of Scientific and Technical Information of China (English)

    渡辺和雄

    2007-01-01

    Since the first practical cryocooled superconducting magnet using a GM-cryocooler and high temperature superconducting current leads has been demonstrated successfully at the High Field Laboratory for Superconducting Materials (HFLSM), various kinds of cryocooled superconducting magnets in fields up to 15 T have been used to provide access for new research areas in fields of magneto-science. Recently, the HFLSM has succeeded in demonstrating a cryocooed 18 T high temperature superconducting magnet and a high field cryocooled 27.5 T hybrid magnet. Cryocooled magnet technology and basic research using high field magnets at the HFLSM are introduced.

  3. High field magnet program at Brookhaven National Laboratory

    CERN Document Server

    Ghosh, A; Muratore, J; Parker, B; Sampson, W; Wanderer, P J; Willen, E

    2000-01-01

    The magnet program at Brookhaven National Laboratory (BNL) is focussed on superconducting magnets for particle accelerators. The effort includes magnet production at the laboratory and in industry, magnet R&D, and test facilities for magnets and superconductors. Nearly 2000 magnets-dipoles, quadrupoles, sextupoles and correctors for the arc and insertion regions-were produced for the Relativistic Heavy Ion Collider (RHIC), which is being commissioned. Currently, production of helical dipoles for the polarized proton program at RHIC, insertion region dipoles for the Large Hadron Collider (LHC) at CERN, and an insertion magnet system for the Hadron-Elektron-Ring- Analage (HERA) collider at Deutsches Elektronen-Synchrotron (DESY) is underway. The R&D effort is exploring dipoles with fields above 10 T for use in post-LHC colliders. Brittle superconductors-Nb/sub 3/Sn or HTS-are being used for these magnets. The superconductor test facility measures short-sample currents and other characteristics of sample...

  4. Conceptual Design of the 45 T Hybrid Magnet at the Nijmegen High Field Magnet Laboratory

    CERN Document Server

    Wiegers, SAJ; Bird, M D; Rook, J; Perenboom, J A A J; Wiegers, S A J; Bonito-Oliva, A; den Ouden, A

    2010-01-01

    A 45 T Hybrid Magnet System is being developed at the Nijmegen High Field Magnet Laboratory as part of the Nijmegen Center for Advanced Spectroscopy. The 45 T Hybrid Magnet System will be used in combination with far-infra-red light produced by a Free Electron Laser under construction directly adjacent to the High Field Magnet Laboratory. The superconducting outsert magnet will consist of three CICC coils wound on a single coil form, using Nb3Sn strands. A test program for strand and cable qualification is underway. The CICC will carry 13 kA and the coils will produce 12 T on axis field in a 600 mm warm bore. The nominal operating temperature will be 4.5 K maintained with forced-flow supercritical helium. The insert magnet will produce 33 T at 40 kA in a 32 mm bore consuming 20 MW, and will consist of four coils. The insert magnet will be galvanically and mechanically isolated from the outsert magnet. Complete system availability for users is expected in 2014. In this paper we will report on the conceptual de...

  5. Chest MRI

    Science.gov (United States)

    Nuclear magnetic resonance - chest; Magnetic resonance imaging - chest; NMR - chest; MRI of the thorax; Thoracic MRI ... healthy enough to filter the contrast. During the MRI, the person who operates the machine will watch ...

  6. Superconductor Requirements and Characterization for High Field Accelerator Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Barzi, E.; Zlobin, A. V.

    2015-05-01

    The 2014 Particle Physics Project Prioritization Panel (P5) strategic plan for U.S. High Energy Physics (HEP) endorses a continued world leadership role in superconducting magnet technology for future Energy Frontier Programs. This includes 10 to 15 T Nb3Sn accelerator magnets for LHC upgrades and a future 100 TeV scale pp collider, and as ultimate goal that of developing magnet technologies above 20 T based on both High Temperature Superconductors (HTS) and Low Temperature Superconductors (LTS) for accelerator magnets. To achieve these objectives, a sound conductor development and characterization program is needed and is herein described. This program is intended to be conducted in close collaboration with U.S. and International labs, Universities and Industry.

  7. High field accelerator magnet R&D in Europe

    CERN Document Server

    Devred, Arnaud; Bottura, L; Chorowski, M; Fabbricatore, P; Leroy, D; den Ouden, A; Rifflet, J M; Rossi, L; Vincent-Viry, O; Volpini, G

    2004-01-01

    The LHC magnet R&D program has shown that the limit of NbTi technology at 1.9 K was in the 10-to-10.5-T range. Hence, to go beyond the 10-T threshold, it is necessary to change the superconducting material. Given the state of the art in HTS, the only serious candidate is Nb3Sn. A series of dipole magnet models built at Twente University and LBNL as well as a vigorous program carried out at Fermilab have demonstrated the feasibility of Nb3Sn magnet technology. The next step is to bring this technology to maturity, which require further conductor and conductor insulation development and a simplification of manufacturing processes. After a brief history, we review ongoing R&D programs in Europe and we present the Next European Dipole (NED) initiative promoted by the European Steering Group on Accelerator R&D (ESGARD).

  8. Quasi permanent superconducting magnet of very high field

    Science.gov (United States)

    Ren, Y.; Liu, J.; Weinstein, R.; Chen, I. G.; Parks, D.; Xu, J.; Obot, V.; Foster, C.

    1993-01-01

    We report on persistent field in a quasi-permanent magnet made of high temperature superconductor. The material has an average of 40 percent molar excess of Y, relative to Y1Ba2Cu3O7 and has been irradiated with high energy light ions at 200 MeV. The magnet, which traps 1.52 T at 77.3 K, traps nearly 4 T at 64.5 K. No evidence of giant flux jump or sample cracking was observed.

  9. High-Field Magnetization of Light Rare-Earth Metals

    DEFF Research Database (Denmark)

    McEwen, K.A.; Cock, G.J.; Roeland, L.W.;

    1973-01-01

    The magnetization of single crystals of Eu, Sm, Nd, Pr, and Pr-Nd alloys has been measured in fields up to 37 T (370 kG). The results give new information on the magnetic properties of these metals. Of particular interest is a first-order transition from a nonmagnetic to a metamagnetic phase...... in double-hexagonal close-packed Pr, due to the crossing of crystal-field levels, when a field of about 32 T is applied in the hard direction at low temperatures....

  10. The new installation at the Nijmegen High Field Magnet Laboratory

    NARCIS (Netherlands)

    Perenboom, J.A.A.J.; Wiegers, S.A.J.; Christianen, P.C.M.; Zeitler, U.; Maan, J.C.

    2004-01-01

    For research in the highest continuous and pulsed magnetic fields large, complex and powerful installations are needed. A new 20 MW installation has been built at the University of Nijmegen. The ultra-low ripple power converter, delivering 40 kA at up to 500 V, provides the capability to perform exp

  11. High field accelerator magnet R&D in Europe

    NARCIS (Netherlands)

    Devred, A.; Baynham, D.E.; Bottura, L.; Chorowski, M.; Fabbricatore, P.; Leroy, D.; Ouden, den A.; Rifflet, J.M.; Rossi, L.; Vincent-Viry, O.; Volpini, G.

    2004-01-01

    The LHC magnet R&D Program has shown that the limit of NbTi technology at 1.8 K was in the range 10 to 10.5 T. Hence, to go beyond the 10-T threshold, it is necessary to change of superconducting material. Given the state of the art in HTS, the only serious candidate is Nb/sub 3/Sn. A series of dipo

  12. Ultrasound versus high field magnetic resonance imaging in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Tan, York Kiat; Østergaard, Mikkel; Bird, Paul;

    2014-01-01

    Over the past decade there have been significant advances in the field of musculoskeletal imaging, especially in the application of ultrasound (US) and magnetic resonance imaging (MRI) to the management of rheumatoid arthritis (RA). Both modalities offer significant advantages over the previous...... standards of clinical examination and radiography, and allow direct visualisation of both joint inflammation and structural damage. Although measuring similar pathology, each of these imaging tools has its own benefits and limitations; understanding these will help researchers and clinicians to determine...

  13. Theoretical Formula and Simulation of Cyclotron Magnet Shimming in High Field Environment

    Institute of Scientific and Technical Information of China (English)

    ZHANG; Dong-sheng; YANG; Jian-jun; LI; Ming

    2015-01-01

    In the computation of cyclotron magnet shimming,trim-rod and magnetic channel,one common process is to calculate the variation of magnet field caused by a small iron piece.Under the circumstance of superconducting cyclotron,high field approximate can be used and we can derive

  14. Gap Filling Ceramic Insulating Putty for High Field Magnets

    Science.gov (United States)

    Rice, J. A.; Rice, H. M.

    2008-03-01

    Gaps between the A15 superconducting cable and its supports can sometimes occur requiring expensive rework of the support or filling with a non-optimal material. Recently, a new ceramic putty has been developed that can fill these gaps to fully support the superconducting cable. This ceramic material can withstand the extreme temperature differences between the high temperature heat treatment and the cryogenic operation. Significant performance improvements have been made that will enable the insulating putty to be used in some accelerator magnet systems. Processing methods will be discussed as well as strength and thermal data.

  15. High-Field Magnetization of the Pyrochlore Compound Gd2Ti2O7

    Science.gov (United States)

    Narumi, Yasuo; Kikkawa, Akiko; Katsumata, Koichi; Honda, Zentaro; Hagiwara, Masayuki; Kindo, Koichi

    2006-09-01

    High-field magnetization measurements have been preformed on a single crystal sample of the pyrochlore compound Gd2Ti2O7 using a pulse magnet in conjunction with a dilution refrigerator. The magnetization curve at 0.3 K reveals two magnetic phase transitions when the magnetic field is applied along b [111]. At temperatures slightly above TN, a magnetization plateau appears around 5 T and the magnetization increases again from about 15 T with a convex curvature. It is considered that this crossover is due to a competition among thermal fluctuations, short-range antiferromagnetic ordering and geometrical frustration.

  16. High-field magnetization of NpRhGa{sub 5}

    Energy Technology Data Exchange (ETDEWEB)

    Sugiyama, K. [Graduate School of Sciences, Osaka University, Toyonaka, Osaka 560-0043 (Japan)]. E-mail: sugiyama@phys.sci.osaka-u.ac.jp; Honda, D. [Graduate School of Sciences, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Nakashima, H. [Graduate School of Sciences, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Aoki, D. [IMR, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Yamamoto, E. [Advanced Science Research Center, JAERI, Tokai, Ibaraki 319-1195 (Japan); Nakamura, A. [Advanced Science Research Center, JAERI, Tokai, Ibaraki 319-1195 (Japan); Honma, K. [IMR, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Shiokawa, Y. [IMR, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Kindo, K. [ISSP, The University of Tokyo, Kashiwanoha 5-1-5, Kashiwa, Chiba 277-8581 (Japan); Hagiwara, M. [KYOKUGEN, Osaka University, Toyonaka, Osaka 560-8531 (Japan); Onuki, Y. [Graduate School of Sciences, Osaka University, Toyonaka, Osaka 560-0043 (Japan)

    2006-05-01

    We have measured the high-field magnetization of NpRhGa{sub 5} with the tetragonal structure and found the sharp metamagnetic transition with a sharp step at 26T in the field along the [100] direction at 4.2K. The magnetization saturates above 38T, with 0.43{mu}{sub B}/Np. The H-T phase diagram was determined by the magnetization curves at various temperatures.

  17. Nb$_3$Sn High Field Magnets for the High Luminosity LHC Upgrade Project

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosio, Giorgio [Fermilab

    2015-01-01

    The High Luminosity upgrade of the Large Hadron Collider at CERN requires a new generation of high field superconducting magnets. High field large aperture quadrupoles (MQXF) are needed for the low-beta triplets close to the ATLAS and CMS detectors, and high field two-in-one dipoles (11 T dipoles) are needed to make room for additional collimation. The MQXF quadrupoles, with a field gradient of 140 T/m in 150 mm aperture, have a peak coil field of 12.1 T at nominal current. The 11 T dipoles, with an aperture of 60 mm, have a peak coil field of 11.6 T at nominal current. Both magnets require Nb3Sn conductor and are the first applications of this superconductor to actual accelerator magnets.

  18. Design of the EuCARD High-Field Model Dipole Magnet FRESCA2

    CERN Document Server

    Milanese, A; Durante, M; Manil, P; Perez, J C; Rifflet, J M; de Rijk, G; Rondeaux, F

    2012-01-01

    This paper reports on the design of FRESCA2, a dipole magnet model wound with Nb3Sn Rutherford cable. This magnet is one of the deliverables of the High Field Magnets work package of the European FP7-EuCARD project. The nominal magnetic flux density of 13 Tesla in a 100 mm bore will make it suitable for upgrading the FRESCA cable test facility at CERN. The magnetic layout is based on a block coil, with four layers per pole. The mechanical structure is designed to provide adequate pre-stress, through the use of bladders, keys and an aluminum alloy shrinking cylinder.

  19. Double degenerate mergers as progenitors of high-field magnetic white dwarfs

    CERN Document Server

    García--Berro, E; Aznar--Siguán, G; Torres, S; Camacho, J; Althaus, L G; Córsico, A H; Külebi, B; Isern, J

    2012-01-01

    High-field magnetic white dwarfs have been long suspected to be the result of stellar mergers. However, the nature of the coalescing stars and the precise mechanism that produces the magnetic field are still unknown. Here we show that the hot, convective, differentially rotating corona present in the outer layers of the remnant of the merger of two degenerate cores is able to produce magnetic fields of the required strength that do not decay for long timescales. We also show, using an state-of-the-art Monte Carlo simulator, that the expected number of high-field magnetic white dwarfs produced in this way is consistent with that found in the Solar neighborhood.

  20. Nb$_3$Sn High Field Magnets for the High Luminosity LHC Upgrade Project

    CERN Document Server

    AUTHOR|(CDS)2075881

    2015-01-01

    The high luminosity upgrade of the Large Hadron Collider at CERN requires a new generation of high field superconducting magnets. High field large aperture quadrupoles (MQXF) are needed for the low-beta triplets close to the ATLAS and CMS detectors, and high field two-in-one dipoles (11-T dipoles) are needed to make room for additional collimation. The MQXF quadrupoles, with a field gradient of 140 T/m in 150 mm aperture, have a peak coil field of 12.1 T at nominal current. The 11-T dipoles, with an aperture of 60 mm, have a peak coil field of 11.6 T at nominal current. Both magnets require Nb3Sn conductor and are the first applications of this superconductor to actual accelerator magnets. Collaboration between the US LARP (LHC Accelerator Research Program) and CERN is developing the MQXF magnets, whereas the 11-T dipole magnets are being developed by CERN and Fermilab. This paper reviews the status of Nb3Sn technology for accelerator magnets, discusses its main challenges, and discusses how the MQXF and 11-T...

  1. Development of High-Field Permanent Magnetic Circuits for NMRI/MRI and Imaging on Mice

    Directory of Open Access Journals (Sweden)

    Guangxin Wang

    2016-01-01

    Full Text Available The high-field permanent magnetic circuits of 1.2 T and 1.5 T with novel magnetic focusing and curved-surface correction are developed. The permanent magnetic circuit comprises a magnetic yoke, main magnetic steel, nonspherical curved-surface magnetic poles, plugging magnetic steel, and side magnetic steel. In this work, a novel shimming method is proposed for the effective correction of base magnetic field (B0 inhomogeneities, which is based on passive shimming on the telescope aspheric cutting, grinding, and fine processing technology of the nonspherical curved-surface magnetic poles and active shimming adding higher-order gradient coils. Meanwhile, the magnetic resonance imaging dedicated alloy with high-saturation magnetic field induction intensity and high electrical resistivity is developed, and nonspherical curved-surface magnetic poles which are made of the dedicated alloy have very good anti-eddy-current effect. In addition, the large temperature coefficient problem of permanent magnet can be effectively controlled by using a high quality temperature controller and deuterium external locking technique. Combining our patents such as gradient coil, RF coil, and integration computer software, two kinds of small animal Micro-MRI instruments are developed, by which the high quality MRI images of mice were obtained.

  2. High-field magnetization process of granular Co-Cu alloys prepared by melt spinning

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    High solid-solubility Co15Cu35 alloys have been prepared by melt spinning and submitted to isothermal and anisothermal annealing to obtain granular alloys.The X-ray diffraction(XRD) patterns were measured to invesugate the decomposition of supersaturated solid solution induced by annealing.The atomic diffusion and structural evolution during the heat treatment were investigated.In view of the problems limiting their appllcation.the high-field magneazation curves were measured.By a fit to the high-field magnetization curves,the granuiar alloys are found hard to be magnetically saturated at the early stage of nucleation and growth.The magnetization behavior was correlaced to the annealed-induced structureal evolution and also to the magnetoresistance effect.

  3. A COMMON COIL DESIGN FOR HIGH FIELD 2 IN 1 ACCELERATOR MAGNETS.

    Energy Technology Data Exchange (ETDEWEB)

    GUPTA,R.

    2002-05-12

    A common coil design concept for 2-in-1 superconducting accelerator magnets is presented. It practically eliminates the major problems in the ends of high field magnets built with either high temperature superconductors (HTS) or conventional superconductors. Racetrack coils, consisting of rectangular blocks built with either superconducting tapes or cables, are common to both apertures with each aperture containing one half of each coil. The ends are easy to wind with the conductors experiencing little strain. The overall magnet design, construction and tooling are also expected to be simpler than in the conventional cosine theta magnets. The concept is also suitable for superferric and combined function magnet designs. A modular design for an HTS based R&D magnet is also presented.

  4. A magnetic trap for high-field seeking neutron spin states

    Directory of Open Access Journals (Sweden)

    Th. Brenner

    2015-02-01

    Full Text Available A first experimental demonstration of a new type of magnetic trap for ultra-cold neutrons is presented. High-field seeking spin-states are trapped in a potential formed by the magnetic field of a straight wire and a repulsive coating on the wire surface. Life-times of the trapped neutrons of 60 s could be observed. This configuration can in principle be used to form bound states of the wave function on the surface of the wire to probe new forces at short distances. Further applications include the use as a guide and selector for perfectly polarized neutrons.

  5. A magnetic trap for high-field seeking neutron spin states

    Energy Technology Data Exchange (ETDEWEB)

    Brenner, Th. [Institut Laue-Langevin, 38042 Grenoble Cedex 9 (France); Chesnevskaya, S. [Physik Department, Technische Universität München, D-85748 Garching (Germany); Fierlinger, P., E-mail: peter.fierlinger@tum.de [Physik Department, Technische Universität München, D-85748 Garching (Germany); Geltenbort, P. [Institut Laue-Langevin, 38042 Grenoble Cedex 9 (France); Gutsmiedl, E. [Physik Department, Technische Universität München, D-85748 Garching (Germany); Lauer, T. [Forschungsneutronenquelle Heinz Maier-Leibnitz, Technische Universität München, D-85748 Garching (Germany); Rezai, K. [University of California at Berkeley, CA 94720 (United States); Rothe, J. [Physik Department, Technische Universität München, D-85748 Garching (Germany); Zechlau, T. [Forschungsneutronenquelle Heinz Maier-Leibnitz, Technische Universität München, D-85748 Garching (Germany); Zou, R. [University of California at Berkeley, CA 94720 (United States)

    2015-02-04

    A first experimental demonstration of a new type of magnetic trap for ultra-cold neutrons is presented. High-field seeking spin-states are trapped in a potential formed by the magnetic field of a straight wire and a repulsive coating on the wire surface. Life-times of the trapped neutrons of 60 s could be observed. This configuration can in principle be used to form bound states of the wave function on the surface of the wire to probe new forces at short distances. Further applications include the use as a guide and selector for perfectly polarized neutrons.

  6. High-field magnetization of rare-earth ions in scandium

    DEFF Research Database (Denmark)

    Roeland, L. W.; Touborg, P.

    1978-01-01

    The magnetic moments of Tb, Dy, or Er ions in dilute Sc single-crystal alloys have been measured in fields up to 280 × 105 A/m (350 kOe). The Zeeman energies in this high field are comparable to the total crystal-field splittings. This gives rise to characteristic features in the magnetization...... curves. The crystal-field parameters obtained previously from experiments in low fields and the Zeeman interaction give a satisfactory quantitative acount of the experimental results....

  7. Formation of high-field magnetic white dwarfs from common envelopes.

    Science.gov (United States)

    Nordhaus, Jason; Wellons, Sarah; Spiegel, David S; Metzger, Brian D; Blackman, Eric G

    2011-02-22

    The origin of highly magnetized white dwarfs has remained a mystery since their initial discovery. Recent observations indicate that the formation of high-field magnetic white dwarfs is intimately related to strong binary interactions during post-main-sequence phases of stellar evolution. If a low-mass companion, such as a planet, brown dwarf, or low-mass star, is engulfed by a post-main-sequence giant, gravitational torques in the envelope of the giant lead to a reduction of the companion's orbit. Sufficiently low-mass companions in-spiral until they are shredded by the strong gravitational tides near the white dwarf core. Subsequent formation of a super-Eddington accretion disk from the disrupted companion inside a common envelope can dramatically amplify magnetic fields via a dynamo. Here, we show that these disk-generated fields are sufficiently strong to explain the observed range of magnetic field strengths for isolated, high-field magnetic white dwarfs. A higher-mass binary analogue may also contribute to the origin of magnetar fields.

  8. The formation of high-field magnetic white dwarfs from common envelopes

    CERN Document Server

    Nordhaus, J; Spiegel, D S; Metzger, B D; Blackman, E G

    2010-01-01

    The origin of highly-magnetized white dwarfs has remained a mystery since their initial discovery. Recent observations indicate that the formation of high-field magnetic white dwarfs is intimately related to strong binary interactions during post-main-sequence phases of stellar evolution. If a low-mass companion, such as a planet, brown dwarf, or low-mass star is engulfed by a post-main-sequence giant, the hydrodynamic drag in the envelope of the giant leads to a reduction of the companion's orbit. Sufficiently low-mass companions in-spiral until they are shredded by the strong gravitational tides near the white dwarf core. Subsequent formation of a super-Eddington accretion disk from the disrupted companion inside a common envelope can dramatically amplify magnetic fields via a dynamo. Here, we show that these disk-generated fields are sufficiently strong to explain the observed range of magnetic field strengths for isolated, high-field magnetic white dwarfs. A higher-mass binary analogue may also contribute...

  9. High Field Pulsed Magnets for Neutron Scattering at the Spallation Neutron Source

    Science.gov (United States)

    Granroth, G. E.; Lee, J.; Fogh, E.; Christensen, N. B.; Toft-Petersen, R.; Nojiri, H.

    2015-03-01

    A High Field Pulsed Magnet (HFPM) setup, is in use at the Spallation Nuetron Source(SNS), Oak Ridge National Laboratory. With this device, we recently measured the high field magnetic spin structure of LiNiPO4. The results of this study will be highlighted as an example of possible measurements that can be performed with this device. To further extend the HFPM capabilities at SNS, we have learned to design and wind these coils in house. This contribution will summarize the magnet coil design optimization procedure. Specifically by varying the geometry of the multi-layer coil, we arrive at a design that balances the maximum field strength, neutron scattering angle, and the field homogeneity for a specific set of parameters. We will show that a 6.3kJ capacitor bank, can provide a magnetic field as high as 30T for a maximum scattering angle around 40° with homogeneity of +/- 4 % in a 2mm diameter spherical volume. We will also compare the calculations to measurements from a recently wound test coil. This work was supported in part by the Lab Directors' Research and Development Fund of ORNL.

  10. High-field magnetization of Heusler compound Fe2Mn1 -xVxSi

    Science.gov (United States)

    Hiroi, Masahiko; Tazoko, Tomoya; Sano, Hiroaki; Shigeta, Iduru; Koyama, Keiichi; Kondo, Akihiro; Kindo, Koich; Manaka, Hirotaka; Terada, Norio

    2017-01-01

    Fe2MnSi exhibits a ferromagnetic transition at TC˜230 K and another transition to a phase with antiferromagnetic components at TA˜60 K. By substituting V for Mn, so as to obtain Fe2Mn1 -xVxSi , TA is revealed to decrease with x and then vanish around x ˜0.2 . In this study, the phase boundary of the transition at TA in the high-field range is found for 0 ≤x ≤0.15 with pulsed fields up to ˜70 T. The magnetization of Fe2Mn1 -xVxSi slowly increases even at the highest field of ˜70 T, though it occurs more gradually as x increases. We compare the magnetization for 0 ≤x ≤0.20 at 62 T with the Slater-Pauling rule, which holds when a Heusler compound is a half-metal, and find fairly good agreement. This suggests an intimate relation between the high-field phase and the half-metallic electronic structure, and that at the high-field limit the phase approaches the half-metallic state, which has been predicted by band-structure calculations.

  11. High-field magnetic phase transitions and spin excitations in magnetoelectric LiNiPO4

    DEFF Research Database (Denmark)

    Toft-Petersen, Rasmus; Jensen, Jens; Jensen, Thomas Bagger Stibius;

    2011-01-01

    The magnetically ordered phases and spin dynamics of magnetoelectric LiNiPO4 have been studied in fields up to 17.3 T along the c axis. Using neutron diffraction, we show that a previously proposed linearly polarized incommensurate (IC) structure exists only for temperatures just below the Neel......, the spiral structure is found to lock in to a period of five crystallographic unit cells along the b axis. Based on the neutron-diffraction data, combined with detailed magnetization measurements along all three crystallographic axes, we establish the magnetic phase diagrams for fields up to 17.3 T along c...... the linear and elliptical polarization of the IC structure, and that a generalization of the spin-wave theory, assuming the random-phase approximation, accounts for the inelastic scattering data obtained in the commensurable uniform phase at fields below 12 T as well as those obtained in the high-field IC...

  12. Pulsed high field magnets. An efficient way of shaping laser accelerated proton beams for application

    Energy Technology Data Exchange (ETDEWEB)

    Kroll, Florian; Schramm, Ulrich [Helmholtz-Zentrum Dresden - Rossendorf, 01328 Dresden (Germany); Technische Universitaet Dresden, 01062 Dresden (Germany); Bagnoud, Vincent; Blazevic, Abel; Busold, Simon [GSI Helmholtzzentrum fuer Schwerionenforschung, 64291 Darmstadt (Germany); Helmholtz Institut Jena, 07734 Jena (Germany); Brabetz, Christian; Schumacher, Dennis [GSI Helmholtzzentrum fuer Schwerionenforschung, 64291 Darmstadt (Germany); Deppert, Oliver; Jahn, Diana; Roth, Markus [Technische Universitaet Darmstadt, 64289 Darmstadt (Germany); Karsch, Leonhard; Masood, Umar [OncoRay-National Center for Radiation Research in Oncology, TU Dresden, 01307 Dresden (Germany); Kraft, Stephan [Helmholtz-Zentrum Dresden - Rossendorf, 01328 Dresden (Germany)

    2015-07-01

    Compact laser-driven proton accelerators are a potential alternative to complex, expensive conventional accelerators, enabling unique beam properties, like ultra-high pulse dose. Nevertheless, they still require substantial development in reliable beam generation and transport. We present experimental studies on capture, shape and transport of laser and conventionally accelerated protons via pulsed high-field magnets. These magnets, common research tools in the fields of solid state physics, have been adapted to meet the demands of laser acceleration experiments.Our work distinctively shows that pulsed magnet technology makes laser acceleration more suitable for application and can facilitate compact and efficient accelerators, e.g. for material research as well as medical and biological purposes.

  13. Stress management as an enabling technology for high-field superconducting dipole magnets

    Science.gov (United States)

    Holik, Eddie Frank, III

    This dissertation examines stress management and other construction techniques as means to meet future accelerator requirement demands by planning, fabricating, and analyzing a high-field, Nb3Sn dipole. In order to enable future fundamental research and discovery in high energy accelerator physics, bending magnets must access the highest fields possible. Stress management is a novel, propitious path to attain higher fields and preserve the maximum current capacity of advanced superconductors by managing the Lorentz stress so that strain induced current degradation is mitigated. Stress management is accomplished through several innovative design features. A block-coil geometry enables an Inconel pier and beam matrix to be incorporated in the windings for Lorentz Stress support and reduced AC loss. A laminar spring between windings and mica paper surrounding each winding inhibit any stress transferral through the support structure and has been simulated with ALGORRTM. Wood's metal filled, stainless steel bladders apply isostatic, surface-conforming preload to the pier and beam support structure. Sufficient preload along with mica paper sheer release reduces magnet training by inhibiting stick-slip motion. The effectiveness of stress management is tested with high-precision capacitive stress transducers and strain gauges. In addition to stress management, there are several technologies developed to assist in the successful construction of a high-field dipole. Quench protection has been designed and simulated along with full 3D magnetic simulation with OPERARTM. Rutherford cable was constructed, and cable thermal expansion data was analysed after heat treatment. Pre-impregnation analysis techniques were developed due to elemental tin leakage in varying quantities during heat treatment from each coil. Robust splicing techniques were developed with measured resistivites consistent with nO joints. Stress management has not been incorporated by any other high field dipole

  14. Thermal Design of an Nb3Sn High Field Accelerator Magnet

    CERN Document Server

    Pietrowicz, S

    2011-01-01

    Within the framework of the European project EuCARD, a Nb3Sn high field accelerator magnet is under design to serve as a test bed for future high field magnets and to upgrade the vertical CERN cable test facility, Fresca. The Fresca 2 block coil type magnet will be operated at 1.9 K or 4.2 K and is designed to produce about 13 T. A 2D numerical thermal model was developed to determinate the temperature margin of the coil in working conditions and the appropriate cool-down scenario. The temperature margin, which is DTmarge=5.8 K at 1.9 K and DTmarge=3.5 K at 4.2 K, was investigated in steady state condition with the AC losses due to field ramp rate as input heat generation. Several cool-down scenarios were examined in order to minimize the temperature difference and therefore reducing the mechanical constraints within the structure. The paper presents the numerical model, the assumptions taken for the calculations and several results of the simulation for the cool-down and temperature distributions due to seve...

  15. Powder-in-tube (PIT) $Nb_{3}Sn$ conductors for high-field magnets

    CERN Document Server

    Lindenhovius, J L H; den Ouden, A; Wessel, W A J; ten Kate, H H J

    2000-01-01

    New Nb/sub 3/Sn conductors, based on the powder-in-tube (PIT) process, have been developed for application in accelerator magnets and high-field solenoids. For application in accelerator magnets, SMI has developed a binary 504 filament PIT conductor by optimizing the manufacturing process and adjustment of the conductor lay-out. It uniquely combines a non-copper current density of 2680 A/mm/sup 2/@10 T with an effective filament diameter of about 20 mu m. This binary conductor may be used in a 10 T, wide bore model separator dipole magnet for the LHC, which is being developed by a collaboration of the University of Twente and CERN. A ternary (Nb/7.5wt%Ta)/sub 3/Sn conductor containing 37 filaments is particularly suited for application in extremely high-field superconducting solenoids. This wire features a copper content of 43%, a non-copper current density of 217 A/mm/sup 2/@20 T and a B/sub c2/ of 25.6 T. The main issues and the experimental results of the development program of PIT Nb/sub 3/Sn conductors a...

  16. Superconductor and cable R&D for high field accelerator magnets at Fermilab

    CERN Document Server

    Barzi, E; Andreev, N; Bauer, P; Chichili, D R; Fratini, M; Elementi, L; Hoffman, J; Limon, P J; Mattafirri, S; Rey, J M; Yamada, R; Zlobin, A V

    2002-01-01

    This paper presents past results and future goals of the Nb/sub 3/Sn strand and cable R&D being performed within the High Field Magnet program at Fermilab. Research tools include a reaction site for Nb /sub 3/Sn, a Short Sample Test Facility, a Scanning Electron Microscope, and a 28-strand cabling machine. Strands of various designs and diameters produced with the Internal Tin, Modified Jelly Roll, and Powder-in-Tube methods, and several Rutherford-type cables were studied. (18 refs).

  17. 2D/3D quench simulation using ANSYS for epoxy impregnated Nb3Sn high field magnets

    Energy Technology Data Exchange (ETDEWEB)

    Ryuji Yamada et al.

    2002-09-19

    A quench program using ANSYS is developed for the high field collider magnet for three-dimensional analysis. Its computational procedure is explained. The quench program is applied to a one meter Nb{sub 3}Sn high field model magnet, which is epoxy impregnated. The quench simulation program is used to estimate the temperature and mechanical stress inside the coil as well as over the whole magnet. It is concluded that for the one meter magnet with the presented cross section and configuration, the thermal effects due to the quench is tolerable. But we need much more quench study and improvements in the design for longer magnets.

  18. High-field proton magnetic resonance spectroscopy reveals metabolic effects of normal brain aging.

    Science.gov (United States)

    Harris, Janna L; Yeh, Hung-Wen; Swerdlow, Russell H; Choi, In-Young; Lee, Phil; Brooks, William M

    2014-07-01

    Altered brain metabolism is likely to be an important contributor to normal cognitive decline and brain pathology in elderly individuals. To characterize the metabolic changes associated with normal brain aging, we used high-field proton magnetic resonance spectroscopy in vivo to quantify 20 neurochemicals in the hippocampus and sensorimotor cortex of young adult and aged rats. We found significant differences in the neurochemical profile of the aged brain when compared with younger adults, including lower aspartate, ascorbate, glutamate, and macromolecules, and higher glucose, myo-inositol, N-acetylaspartylglutamate, total choline, and glutamine. These neurochemical biomarkers point to specific cellular mechanisms that are altered in brain aging, such as bioenergetics, oxidative stress, inflammation, cell membrane turnover, and endogenous neuroprotection. Proton magnetic resonance spectroscopy may be a valuable translational approach for studying mechanisms of brain aging and pathology, and for investigating treatments to preserve or enhance cognitive function in aging.

  19. Tuning magnetic disorder in diluted magnetic semiconductors using high fields to 89 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Crooker, Scott A [Los Alamos National Laboratory; Samarth, Nitin [PENN STATE U

    2008-01-01

    We describe recent and ongoing studies at the National High Magnetic Field Laboratory at Los Alamos using the new '100 Tesla Multi-Shot Magnet', which is presently delivering fields up to {approx}89 T during its commissioning. We discuss the first experiments performed in this magnet system, wherein the linewidth of low-temperature photoluminescence spectra was used to directly reveal the degree of magnetic alloy disorder 'seen' by excitons in single Zn{sub 0.80}Cd{sub 0.22}Mn{sub 0.08}Se quantum wells. The magnetic potential landscape in II-VI diluted magnetic semiconductors (DMS) is typically smoothed when the embedded Mn{sup 2+} spins align in an applied field. However, an important (but heretofore untested) prediction of current models of compositional disorder is that magnetic alloy fluctuations in many DMS compounds should increase again in very large magnetic fields approaching 100 T. We observed precisely this increase above {approx}70 T, in agreement with a simple model of magnetic alloy disorder.

  20. Oxypnictide SmFeAs(O,F) superconductor: a candidate for high-field magnet applications.

    Science.gov (United States)

    Iida, Kazumasa; Hänisch, Jens; Tarantini, Chiara; Kurth, Fritz; Jaroszynski, Jan; Ueda, Shinya; Naito, Michio; Ichinose, Ataru; Tsukada, Ichiro; Reich, Elke; Grinenko, Vadim; Schultz, Ludwig; Holzapfel, Bernhard

    2013-01-01

    The recently discovered oxypnictide superconductor SmFeAs(O,F) is the most attractive material among the Fe-based superconductors due to its highest transition temperature of 56 K and potential for high-field performance. In order to exploit this new material for superconducting applications, the knowledge and understanding of its electro-magnetic properties are needed. Recent success in fabricating epitaxial SmFeAs(O,F) thin films opens a great opportunity to explore their transport properties. Here we report on a high critical current density of over 10(5) A/cm(2) at 45 T and 4.2 K for both main field orientations, feature favourable for high-field magnet applications. Additionally, by investigating the pinning properties, we observed a dimensional crossover between the superconducting coherence length and the FeAs interlayer distance at 30-40 K, indicative of a possible intrinsic Josephson junction in SmFeAs(O,F) at low temperatures that can be employed in electronics applications such as a terahertz radiation source and a superconducting Qubit.

  1. Cost Effective Open Geometry HTS MRI System amended to BSCCO 2212 Wire for High Field Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Kennth Marken

    2006-08-11

    the project start and that date a substantial shift in the MRI marketplace occurred, with rapid growth for systems at higher fields (1.5 T and above) and a consequent decline in the low field market (<1.0 T). While the project aim appeared technically attainable at that time, the conclusion was reached that the system and market economics do not warrant additional investment. The program was redirected to develop BSCCO 2212 multifilament wire development for high field superconducting magnets for NMR and other scientific research upon an agreement between DOE and Oxford Instruments, Superconducting Technology. The work t took place between September, 2004 and the project end in early 2006 was focused on 2212 multifilamentary wire. This report summarizes the technical achievements both in 2212 dip coated for an HTS MRI system and in BSCCO 2212 multifilamentary wire for high field magnets.

  2. ADVANCED MAGNETIC RESONANCE IMAGING OF CEREBRAL CAVERNOUS MALFORMATIONS: I. HIGH FIELD IMAGING OF EXCISED HUMAN LESIONS

    Science.gov (United States)

    Shenkar, Robert; Venkatasubramanian, Palamadai N.; Zhao, Jin-cheng; Batjer, H. Hunt; Wyrwicz, Alice M.; Awad, Issam A.

    2008-01-01

    Objectives We hypothesized that structural details would be revealed in cerebral cavernous malformations (CCMs) through the use of high field magnetic resonance (MR) and confocal microscopy, which have not been described previously. The structural details of CCMs excised from human patients were sought by examination with high field MR imaging, and correlated with confocal microscopy of the same specimens. Novel features of CCM structure are outlined, including methodological limitations, venues for future research and possible clinical implications. Methods CCM lesions excised from four patients were fixed in 2% paraformaldehyde and subjected to high resolution MR imaging at 9.4 or 14.1 Tesla by spin-echo and gradient recalled echo methods. Histological validation of angioarchitecture was conducted on thick sections of CCM lesions using fluorescent probes to endothelium under confocal microscopy. Results Images of excised human CCM lesions were acquired with proton density-weighted, T1-weighted, T2-weighted spin echo and T2*-weighted gradient-recalled echo MR. These images revealed large “bland” regions with thin walled caverns, and “honeycombed” regions with notable capillary proliferation and smaller caverns surrounding larger caverns. Proliferating capillaries and caverns of various sizes were also associated with the wall of apparent larger blood vessels in the lesions. Similar features were confirmed within thick sections of CCMs by confocal microscopy. MR relaxation times in different regions of interest suggested the presence of different states of blood breakdown products in areas with apparent angiogenic proliferative activity. Conclusions The high field MR imaging techniques demonstrate novel features of CCM angioarchitecture, visible at near histological resolution, including regions with apparently different biologic activity. These preliminary observations will motivate future research, correlating lesion biologic and clinical activity with

  3. Tunable High-Field Magnetization in Strongly Exchange-Coupled Freestanding Co/CoO Core/Shell Coaxial Nanowires.

    Science.gov (United States)

    Salazar-Alvarez, German; Geshev, Julian; Agramunt-Puig, Sebastià; Navau, Carles; Sanchez, Alvaro; Sort, Jordi; Nogués, Josep

    2016-08-31

    The exchange bias properties of Co/CoO coaxial core/shell nanowires were investigated with cooling and applied fields perpendicular to the wire axis. This configuration leads to unexpected exchange-bias effects. First, the magnetization value at high fields is found to depend on the field-cooling conditions. This effect arises from the competition between the magnetic anisotropy and the Zeeman energies for cooling fields perpendicular to the wire axis. This allows imprinting predefined magnetization states to the antiferromagnetic (AFM) shell, as corroborated by micromagnetic simulations. Second, the system exhibits a high-field magnetic irreversibility, leading to open hysteresis loops attributed to the AFM easy axis reorientation during the reversal (effect similar to athermal training). A distinct way to manipulate the high-field magnetization in exchange-biased systems, beyond the archetypical effects, was thus experimentally and theoretically demonstrated.

  4. High-field electron transport in GaN under crossed electric and magnetic fields

    Science.gov (United States)

    Kochelap, V. A.; Korotyeyev, V. V.; Syngayivska, G. I.; Varani, L.

    2015-10-01

    High-field electron transport studied in crossed electric and magnetic fields in bulk GaN with doping of 1016 cm-3, compensation around 90% at the low lattice temperature (30 K). It was found the range of the magnetic and electric fields where the non-equilibrium electron distribution function has a complicated topological structure in the momentum space with a tendency to the formation of the inversion population. Field dependences of dissipative and Hall components of the drift velocity were calculated for the samples with short- and open- circuited Hall contacts in wide ranges of applied electric (0 — 20 kV/cm) and magnetic (1 — 10 T) fields. For former sample, field dependences of dissipative and Hall components of the drift velocity have a non-monotonic behavior. The dissipative component has the inflection point which corresponds to the maximum point of the Hall component. For latter sample, the drift velocity demonstrate a usual sub-linear growth without any critical points. We found that GaN samples with controlled resistance of the Hall circuit can be utilized as a electronic high-power switch.

  5. High field nuclear magnetic resonance in transition metal substituted BaFe2As2

    Science.gov (United States)

    Garitezi, T. M.; Lesseux, G. G.; Rosa, P. F. S.; Adriano, C.; Reyes, A. P.; Kuhns, P. L.; Pagliuso, P. G.; Urbano, R. R.

    2014-05-01

    We report high field 75As nuclear magnetic resonance (NMR) measurements on Co and Cu substituted BaFe2As2 single crystals displaying same structural/magnetic transition T0≃128 K. From our anisotropy studies in the paramagnetic state, we strikingly found virtually identical quadrupolar splitting and consequently the quadrupole frequency νQ≃2.57(1) MHz for both compounds, despite the claim that each Cu delivers 2 extra 3d electrons in BaFe2As2 compared to Co substitution. These results allow us to conclude that a subtle change in the crystallographic structure, particularly in the Fe-As tetrahedra, must be the most probable tuning parameter to determine T0 in this class of superconductors rather than electronic doping. Furthermore, our NMR data around T0 suggest coexistence of tetragonal/paramagnetic and orthorhombic/antiferromagnetic phases between the structural and the spin density wave magnetic phase transitions, similarly to what was reported for K-doped BaFe2As2 [Urbano et al., Phys. Rev. Lett. 105, 107001 (2010)].

  6. Costs of high-field superconducting strands for particle accelerator magnets

    CERN Document Server

    Cooley, L D; Scanlan, R M; 10.1088/0953-2048/18/4/R01

    2005-01-01

    The costs of superconducting magnet strands are compared by calculating a 'production scaling factor' P that relates purchase data to the cost of raw materials. Using a consistent method, we normalize for different conductor geometries and strand diameters to arrive at cost indices in $ kg/sup -1/, $ m/sup -1/, and $ kA/sup -1/ m/sup -1/. Analyses of Nb47Ti conductors taken from the past 25 years of high-field magnet projects reveal that the price of raw materials and, to a lesser extent, finished strands, have tracked the price of niobium pentoxide. Performance gains during the 1980s produced $ kA /sup -1/ m/sup -1/ indices that fell with time ahead of strand cost in $ m/sup -1/, a situation that may reflect the present status of Nb /sub 3/Sn magnet conductors. Analyses of present materials show that P decreases systematically with billet mass. While production strands in 200-500 kg billets have costs ~3 times the cost of raw materials, the 20-50 kg billet size for internal-tin Nb/sub 3/Sn composites drives ...

  7. Shrink Tube Insulation Apparatus for Rebco Superconducting Tapes for Use in High Field Magnets

    CERN Document Server

    Whittington, Andrew

    An increasing number of applications require the use of high temperature superconductors (HTS) such as (RE=Rare Earth) Ba2Cu3O7-x (REBCO) coated conductors [1]. HTS conductors show particularly great potential for high field magnets applications [1] due to their high upper critical fields [2], But several groups have shown that REBCO coated conductors are prone to delamination failure [3] [4] [5]. Under relatively low transverse stress the HTS film separates from the substrate and the conductor degrades [6]. This is problematic due to high transverse stresses that occur in fully epoxy impregnated solenoids wound with this conductor. Application of thin walled heat shrink tubing introduces a weak plane around the conductor, preventing delamination degradation [7]. However, manual application of the shrink tubing is impractical, requiring three operators limited to insulating 100 m lengths or less of REBCO conductor. The high risk of damage to the conductor, also associated with this process, shows the need for...

  8. Magnetic susceptibility at high fields of Pb{sub 2}V{sub 3}O{sub 9}

    Energy Technology Data Exchange (ETDEWEB)

    Waki, T. [Department of Chemistry, Graduate School of Science, Kyoto University, Kyoto 606-8502 (Japan)]. E-mail: twac@issp.u-tokyo.ac.jp; Tsujii, N. [National Institute for Materials Science, Sengen 1-2-1, Tsukuba 305-0047 (Japan); Itoh, Y. [Department of Chemistry, Graduate School of Science, Kyoto University, Kyoto 606-8502 (Japan); Michioka, C. [Department of Chemistry, Graduate School of Science, Kyoto University, Kyoto 606-8502 (Japan); Yoshimura, K. [Department of Chemistry, Graduate School of Science, Kyoto University, Kyoto 606-8502 (Japan); Suzuki, O. [National Institute for Materials Science, Sengen 1-2-1, Tsukuba 305-0047 (Japan); Kitazawa, H. [National Institute for Materials Science, Sengen 1-2-1, Tsukuba 305-0047 (Japan); Kido, G. [National Institute for Materials Science, Sengen 1-2-1, Tsukuba 305-0047 (Japan)

    2007-08-01

    The temperature dependence of magnetic susceptibility was measured for the S=12 quasi one dimensional antiferromagnet Pb{sub 2}V{sub 3}O{sub 9} under the steady magnetic field up to {mu}{sub 0}H=30 T. This material has alternating exchange interaction and a spin-gap at zero magnetic field. An anomaly of magnetic susceptibility indicating the field-induced antiferromagnetic long-range order was observed in high magnetic fields. The Neel temperature at high fields is much lower than the calculated value based on the standard mean-field theory of field-induced magnetic order.

  9. Slotted cage resonator for high-field magnetic resonance imaging of rodents

    Energy Technology Data Exchange (ETDEWEB)

    Marrufo, O; Vasquez, F; Solis, S E; Rodriguez, A O, E-mail: arog@xanum.uam.mx [Departamento de Ingenieria Electrica, Universidad Autonoma Metropolitana Iztapalapa, Mexico, DF 09340 (Mexico)

    2011-04-20

    A variation of the high-frequency cavity resonator coil was experimentally developed according to the theoretical frame proposed by Mansfield in 1990. Circular slots were used instead of cavities to form the coil endplates and it was called the slotted cage resonator coil. The theoretical principles were validated via a coil equivalent circuit and also experimentally with a coil prototype. The radio frequency magnetic field, B1, produced by several coil configurations was numerically simulated using the finite-element approach to investigate their performances. A transceiver coil, 8 cm long and 7.6 cm in diameter, and composed of 4 circular slots with a 15 mm diameter on both endplates, was built to operate at 300 MHz and quadrature driven. Experimental results obtained with the slotted cage resonator coil were presented and showed very good agreement with the theoretical expectations for the resonant frequency as a function of the coil dimensions and slots. A standard birdcage coil was also built for performance comparison purposes. Phantom images were then acquired to compute the signal-to-noise ratio of both coils showing an important improvement of the slotted cage coil over the birdcage coil. The whole-body images of the mouse were also obtained showing high-quality images. Volume resonator coils can be reliably built following the physical principles of the cavity resonator design for high-field magnetic resonance imaging applications of rodents.

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Chest Magnetic resonance imaging (MRI) of the chest ... limitations of MRI of the Chest? What is MRI of the Chest? Magnetic resonance imaging (MRI) is ...

  11. ECG-based gating in ultra high field cardiovascular magnetic resonance using an independent component analysis approach

    OpenAIRE

    Krug, Johannes W; Rose, Georg; Clifford, Gari D.; Oster, Julien

    2013-01-01

    Background In Cardiovascular Magnetic Resonance (CMR), the synchronization of image acquisition with heart motion is performed in clinical practice by processing the electrocardiogram (ECG). The ECG-based synchronization is well established for MR scanners with magnetic fields up to 3 T. However, this technique is prone to errors in ultra high field environments, e.g. in 7 T MR scanners as used in research applications. The high magnetic fields cause severe magnetohydrodynamic (MHD) effects w...

  12. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI of the Chest? What is MRI of the Chest? Magnetic resonance imaging (MRI) is a noninvasive ... of page What are some common uses of the procedure? MR imaging of the chest is performed ...

  13. Numerical study of the thermal behavior of an Nb3Sn high field magnet in He II

    Science.gov (United States)

    Pietrowicz, S.; Baudouy, B.

    2013-01-01

    The high field magnet (HFM) project, within the European project EuCARD, aims at constructing an Nb3Sn high field accelerator magnet, the Fresca 2 magnet. This magnet is to serve as a test bed for future high field magnets and to upgrade the vertical CERN cable test facility. Fresca 2 is a block coil type magnet designed to produce 13 T at 1.9 K. To calculate the temperature margin and the evolution of the temperature due to a quench event within the magnet, we developed a 3D model implemented in ANSYS-CFX® software. This model is an extension of the 2D simplified "two-fluid model" proposed by Kitamura et al. with conjugate heat transfer and Kapitza resistance. This model is derived from the original two-fluid model and consisted of a conventional continuity equation, a modified momentum equation for the total fluid and an energy equation including the Gorter-Mellink internal convection term modeling the turbulence regime. The paper presents the model, the numerical schemes, the assumptions taken for the calculations and the results of the simulation obtained for the temperature evolution due to AC losses and due to quench heating within the magnet structure.

  14. Analysis of Uncertainties in Protection Heater Delay Time Measurements and Simulations in Nb$_{3}$Sn High-Field Accelerator Magnets

    CERN Document Server

    Salmi, Tiina; Marchevsky, Maxim; Bajas, Hugo; Felice, Helene; Stenvall, Antti

    2015-01-01

    The quench protection of superconducting high-field accelerator magnets is presently based on protection heaters, which are activated upon quench detection to accelerate the quench propagation within the winding. Estimations of the heater delay to initiate a normal zone in the coil are essential for the protection design. During the development of Nb3Sn magnets for the LHC luminosity upgrade, protection heater delays have been measured in several experiments, and a new computational tool CoHDA (Code for Heater Delay Analysis) has been developed for heater design. Several computational quench analyses suggest that the efficiency of the present heater technology is on the borderline of protecting the magnets. Quantifying the inevitable uncertainties related to the measured and simulated delays is therefore of pivotal importance. In this paper, we analyze the uncertainties in the heater delay measurements and simulations using data from five impregnated high-field Nb3Sn magnets with different heater geometries. ...

  15. A design of novel type superconducting magnet for super-high field functional magnetic resonance imaging by using the harmonic analysis method of magnetic vector potentials

    Institute of Scientific and Technical Information of China (English)

    俎栋林; 郭华; 宋枭禹; 包尚联

    2002-01-01

    The approach of expanding the magnetic scalar potential in a series of Legendre polynomials is suitable for designing a conventional superconducting magnetic resonance imaging magnet of distributed solenoidal configuration. Whereas the approach of expanding the magnetic vector potential in associated Legendre harmonics is suitable for designing a single-solenoid magnet that has multiple tiers, in which each tier may have multiple layers with different winding lengths. A set of three equations to suppress some of the lowest higher-order harmonics is found. As an example, a 4T single-solenoid magnetic resonance imaging magnet with 4 × 6 layers of superconducting wires is de signed The degree of homogeneity in the 0.5m diameter sphere volume is better than 5.8 ppm. The same degree of homogeneity is retained after optimal integralization of turns in each correction layer. The ratio Bm/Bo in the single-solenoid magnet is 30%lower than that in the conventional six-solenoid magnet. This tolerates higher rated superconducting current in the coil. The Lorentz force of the coil in the single-solenoid system is also much lower than in the six-solenoid system. This novel type of magnet possesses significant advantage over conventional magnets, especially when used as a super-high field functional magnetic resonance imaging magnet.

  16. Genetic dissection of the mouse brain using high-field magnetic resonance microscopy.

    Science.gov (United States)

    Badea, A; Johnson, G A; Williams, R W

    2009-05-01

    Magnetic resonance (MR) imaging has demonstrated that variation in brain structure is associated with differences in behavior and disease state. However, it has rarely been practical to prospectively test causal models that link anatomical and functional differences in humans. In the present study we have combined classical mouse genetics with high-field MR to systematically explore and test such structure-functional relations across multiple brain regions. We segmented 33 regions in two parental strains-C57BL/6J (B) and DBA/2J (D)-and in nine BXD recombinant inbred strains. All strains have been studied extensively for more than 20 years using a battery of genetic, functional, anatomical, and behavioral assays. We compared levels of variation within and between strains and sexes, by region, and by system. Average within-strain variation had a coefficient of variation (CV) of 1.6% for the whole brain; while the CV ranged from 2.3 to 3.6% for olfactory bulbs, cortex and cerebellum, and up to approximately 18% for septum and laterodorsal thalamic nucleus. Variation among strain averages ranged from 6.7% for cerebellum, 7.6% for whole brain, 9.0% for cortex, up to approximately 26% for the ventricles, laterodorsal thalamic nucleus, and the interpeduncular nucleus. Heritabilities averaged 0.60+/-0.18. Sex differences were not significant with the possible (and unexpected) exception of the pons ( approximately 20% larger in males). A correlation matrix of regional volumes revealed high correlations among functionally related parts of the CNS (e.g., components of the limbic system), and several high correlations between regions that are not anatomically connected, but that may nonetheless be functionally or genetically coupled.

  17. Measuring aortic pulse wave velocity using high-field cardiovascular magnetic resonance: comparison of techniques

    Directory of Open Access Journals (Sweden)

    Shaffer Jean M

    2010-05-01

    Full Text Available Abstract Background The assessment of arterial stiffness is increasingly used for evaluating patients with different cardiovascular diseases as the mechanical properties of major arteries are often altered. Aortic stiffness can be noninvasively estimated by measuring pulse wave velocity (PWV. Several methods have been proposed for measuring PWV using velocity-encoded cardiovascular magnetic resonance (CMR, including transit-time (TT, flow-area (QA, and cross-correlation (XC methods. However, assessment and comparison of these techniques at high field strength has not yet been performed. In this work, the TT, QA, and XC techniques were clinically tested at 3 Tesla and compared to each other. Methods Fifty cardiovascular patients and six volunteers were scanned to acquire the necessary images. The six volunteer scans were performed twice to test inter-scan reproducibility. Patient images were analyzed using the TT, XC, and QA methods to determine PWV. Two observers analyzed the images to determine inter-observer and intra-observer variabilities. The PWV measurements by the three methods were compared to each other to test inter-method variability. To illustrate the importance of PWV using CMR, the degree of aortic stiffness was assessed using PWV and related to LV dysfunction in five patients with diastolic heart failure patients and five matched volunteers. Results The inter-observer and intra-observer variability results showed no bias between the different techniques. The TT and XC results were more reproducible than the QA; the mean (SD inter-observer/intra-observer PWV differences were -0.12(1.3/-0.04(0.4 for TT, 0.2(1.3/0.09(0.9 for XC, and 0.6(1.6/0.2(1.4 m/s for QA methods, respectively. The correlation coefficients (r for the inter-observer/intra-observer comparisons were 0.94/0.99, 0.88/0.94, and 0.83/0.92 for the TT, XC, and QA methods, respectively. The inter-scan reproducibility results showed low variability between the repeated

  18. Vol. 34 - Optimization of quench protection heater performance in high-field accelerator magnets through computational and experimental analysis

    CERN Document Server

    Salmi, Tiina

    2016-01-01

    Superconducting accelerator magnets with increasingly hi gh magnetic fields are being designed to improve the performance of the Large Hadron Collider (LHC) at CERN. One of the technical challenges is the magnet quench p rotection, i.e., preventing damage in the case of an unexpected loss of superc onductivity and the heat generation related to that. Traditionally this is d one by disconnecting the magnet current supply and using so-called protection he aters. The heaters suppress the superconducting state across a large fraction of the winding thus leading to a uniform dissipation of the stored energy. Preli minary studies suggested that the high-field Nb 3 Sn magnets under development for the LHC luminosity upgrade (HiLumi) could not be reliably protected using the existing heaters. In this thesis work I analyzed in detail the present state-of-the-art protection heater technology, aiming to optimize its perfo rmance and evaluate the prospects in high-field magnet protection. The heater efficiency analyses ...

  19. High field magnetic behavior in Boron doped Fe2VAl Heusler alloys

    Science.gov (United States)

    Venkatesh, Ch.; Vasundhara, M.; Srinivas, V.; Rao, V. V.

    2016-11-01

    We have investigated the magnetic behavior of Fe2VAl1-xBx (x=0, 0.03, 0.06 and 0.1) alloys under high temperature and high magnetic field conditions separately. Although, the low temperature DC magnetization data for the alloys above x>0 show clear magnetic transitions, the zero field cooled (ZFC) and field cooled (FC) curves indicate the presence of spin cluster like features. Further, critical exponent (γ) deduced from the initial susceptibility above the Tc, does not agree with standard models derived for 3 dimensional long range magnetic systems. The deviation in γ values are consistent with the short range magnetic nature of these alloys. We further extend the analysis of magnetic behavior by carrying the magnetization measurements at high temperatures and high magnetic fields distinctly. We mainly emphasize the following observations; (i) The magnetic hysteresis loops show sharp upturns at lower fields even at 900 K for all the alloys. (ii) High temperature inverse susceptibility do not overlap until T=900 K, indicating the persistent short range magnetic correlations even at high temperatures. (iii) The Arrott's plot of magnetization data shows spontaneous moment (MS) for the x=0 alloy at higher magnetic fields which is absent at lower fields (magnetic heterogeneous phases which are not detected from the X-ray diffraction method.

  20. Safety implications of high-field MRI: actuation of endogenous magnetic iron oxides in the human body.

    Directory of Open Access Journals (Sweden)

    Jon Dobson

    Full Text Available BACKGROUND: Magnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla are becoming increasingly common. In light of recent European Union moves to limit high-field exposure for those working with MRI scanners, we have evaluated the potential for detrimental cellular effects via nanomagnetic actuation of endogenous iron oxides in the body. METHODOLOGY: Theoretical models and experimental data on the composition and magnetic properties of endogenous iron oxides in human tissue were used to analyze the forces on iron oxide particles. PRINCIPAL FINDING AND CONCLUSIONS: Results show that, even at 9.4 Tesla, forces on these particles are unlikely to disrupt normal cellular function via nanomagnetic actuation.

  1. Zero-field nuclear magnetic resonance in high field by modulated rf sequences.

    Science.gov (United States)

    Nishiyama, Yusuke; Yamazaki, Toshio

    2007-04-07

    The authors propose a novel approach to design and evaluate sequences for zero-field NMR spectra in high field (ZFHF) by using amplitude and phase modulated rf sequences. ZFHF provide sharp peaks for the dipolar interaction between two nuclear spins even if the orientation of the molecules is distributed. The internuclear distance r can be directly obtained from the peak position which is proportional to r-3. Numerous ZFHF sequences are obtained. A sequence is selected from them by the systematic evaluation of the sequences. The new ZFHF sequence is less affected by chemical shift anisotropy (CSA) than the previous sequences; the sequence can be used for systems with large CSA such as a dipolar coupled 13C-pair system under realistically high field. 13C ZFHF spectra of 13C2 diammonium succinate and 13C2 diammonium oxalate were observed under the 9.4 T field.

  2. A high-field pulsed magnet system for x-ray scattering studies in Voigt geometry

    CERN Document Server

    Islam, Zahirul; Ruff, Jacob P C; Das, Ritesh K; Trakhtenberg, Emil; Nojiri, Hiroyuki; Narumi, Yasuo; Canfield, Paul C

    2011-01-01

    We present a new pulsed-magnet system that enables x-ray single-crystal diffraction in addition to powder and spectroscopic studies in Voigt geometry. The apparatus consists of a large-bore solenoid, cooled by liquid nitrogen. A second independent closed-cycle cryostat is used for cooling samples near liquid helium temperatures. Pulsed magnetic fields up to ~30 T with a minimum of ~6 ms in total duration are generated by discharging a 40 kJ capacitor bank into the magnet coil. The unique characteristic of this instrument is the preservation of maximum scattering angle (~23.6 deg.) through the magnet bore by virtue of a novel double-funnel insert. This instrument would facilitate x-ray diffraction and spectroscopic studies that are impractical, if not impossible, to perform using conventional split-pair magnets and offers a practical solution for preserving optical access in future higher-field pulsed magnets.

  3. The issues and tentative solutions for contrast-enhanced magnetic resonance imaging at ultra-high field strength.

    Science.gov (United States)

    Fries, Peter; Morelli, John N; Lux, Francois; Tillement, Olivier; Schneider, Günther; Buecker, Arno

    2014-01-01

    Magnetic resonance imaging (MRI) performed at ultra-high field strengths beyond 3 Tesla (T) has become increasingly prevalent in research and preclinical applications. As such, the inevitable clinical implementation of such systems lies on the horizon. The major benefit of ultra-high field MRI is the markedly increased signal-to-noise ratios achievable, enabling acquisition of MR images with simultaneously greater spatial and temporal resolution. However, at field strengths higher than 3 T, the efficacy of Gd(III)-based contrast agents is diminished due to decreased r1 relaxivity, somewhat limiting imaging of the vasculature and contrast-enhanced imaging of tumors. There have been extensive efforts to design new contrast agents with high r1 relaxivities based on macromolecular compounds or nanoparticles; however, the efficacy of these agents at ultra-high field strengths has not yet been proven. The aim of this review article is to provide an overview of the basic principles of MR contrast enhancement processes and to highlight the main factors influencing relaxivity. In addition, challenges and opportunities for contrast-enhanced MRI at ultra-high field strengths will be explored. Various approaches for the development of effective contrast agent molecules that are suitable for a broad spectrum of applied field strengths will be discussed in the context of the current literature.

  4. Magnetic resonance imaging of the chest: current and new applications, with an emphasis on pulmonology

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcel Koenigkam; Mauad, Fernando Marum, E-mail: marcelk46@yahoo.com.b [Universidade de Sao Paulo (HC/FMRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas; Elias Junior, Jorge; Muglia, Valdair Francisco [Universidade de Sao Paulo (FMRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Secao de Radiologia

    2011-03-15

    The objective of the present review study was to present the principal applications of magnetic resonance imaging (MRI) of the chest, including the description of new techniques. Over the past decade, this method has evolved considerably because of the development of new equipment, including the simultaneous interconnection of phased-array multiple radiofrequency receiver coils and remote control of the table movement, in addition to faster techniques of image acquisition, such as parallel imaging and partial Fourier acquisitions, as well as the introduction of new contrast agents. All of these advances have allowed MRI to gain ground in the study of various pathologies of the chest, including lung diseases. Currently, MRI is considered the modality of choice for the evaluation of lesions in the mediastinum and in the chest wall, as well as of superior sulcus tumors. However, it can also facilitate the diagnosis of lung, pleural, and cardiac diseases, as well as of those related to the pulmonary vasculature. Pulmonary MRI angiography can be used in order to evaluate various pulmonary vascular diseases, and it has played an ever greater role in the study of thromboembolism. Because cardiac MRI allows morphological and functional assessment in the same test, it has also become part of the clinical routine in the evaluation of various cardiac diseases. Finally, the role of MRI has been extended to the identification and characterization of pulmonary nodules, the evaluation of airway diseases, and the characterization of pleural effusion. (author)

  5. In vivo high field magnetic resonance imaging and spectroscopy of adult zebrafish

    NARCIS (Netherlands)

    Kabli, Samira

    2009-01-01

    This thesis contains the results of imaging of adult zebrafish by using different MR approaches. We present the first high resolution mMR images of adult zebrafish. To achieve high spatial resolution we used a magnetic field of 9.4T, in combination with strong magnetic field gradients (1000 mT/m) an

  6. High-field magnetic resonance imaging of the human temporal lobe

    Directory of Open Access Journals (Sweden)

    Luis M. Colon-Perez

    2015-01-01

    Conclusions: Fresh ex vivo MR imaging, along with tractography, revealed complex intra-temporal structural variation corresponding to neuronal cell body layers, dendritic fields, and axonal projection systems evident histologically. This is the first study to describe in detail the human temporal lobe structural organization using high-field MR imaging and tractography. By preserving the 3-dimensional structures of the hippocampus and surrounding structures, specific changes in anatomy may inform us about the changes that occur in TLE in relation to the disease process and structural underpinnings in epilepsy-related memory dysfunction.

  7. Low and High Field Magnetic Resonance for in Vivo Analysis of Seeds

    Directory of Open Access Journals (Sweden)

    Thomas Neuberger

    2011-08-01

    Full Text Available Low field NMR has been successfully used for the evaluation of seed composition and quality, but largely only in crop species. We show here that 1.5T NMR provides a reliable means for analysing the seed lipid fraction present in a wide range of species, where both the seed size and lipid concentration differed by >10 fold. Little use of high field NMR has been made in seed research to date, even though it potentially offers many opportunities for studying seed development, metabolism and storage. Here we demonstrate how 17.5T and 20T NMR can be applied to image seed structure, and analyse lipid and metabolite distribution. We suggest that further technical developments in NMR/MRI will facilitate significant advances in our understanding of seed biology.

  8. Research and Development of Wires and Cables for High-Field Accelerator Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Barzi, Emanuela; Zlobin, Alexander V.

    2016-04-01

    The latest strategic plans for High Energy Physics endorse steadfast superconducting magnet technology R&D for future Energy Frontier Facilities. This includes 10 to 16 T Nb3Sn accelerator magnets for the luminosity upgrades of the Large Hadron Collider and eventually for a future 100 TeV scale proton-proton (pp) collider. This paper describes the multi-decade R&D investment in the Nb3Sn superconductor technology, which was crucial to produce the first reproducible 10 to 12 T accelerator-quality dipoles and quadrupoles, as well as their scale-up. We also indicate prospective research areas in superconducting Nb3Sn wires and cables to achieve the next goals for superconducting accelerator magnets. Emphasis is on increasing performance and decreasing costs while pushing the Nb3Sn technology to its limits for future pp colliders.

  9. Invited Article: Development of high-field superconducting Ioffe magnetic traps

    Science.gov (United States)

    Yang, L.; Brome, C. R.; Butterworth, J. S.; Dzhosyuk, S. N.; Mattoni, C. E. H.; McKinsey, D. N.; Michniak, R. A.; Doyle, J. M.; Golub, R.; Korobkina, E.; O'Shaughnessy, C. M.; Palmquist, G. R.; Seo, P.-N.; Huffman, P. R.; Coakley, K. J.; Mumm, H. P.; Thompson, A. K.; Yang, G. L.; Lamoreaux, S. K.

    2008-03-01

    We describe the design, construction, and performance of three generations of superconducting Ioffe magnetic traps. The first two are low current traps, built from four racetrack shaped quadrupole coils and two solenoid assemblies. Coils are wet wound with multifilament NbTi superconducting wires embedded in epoxy matrices. The magnet bore diameters are 51 and 105mm with identical trap depths of 1.0T at their operating currents and at 4.2K. A third trap uses a high current accelerator-type quadrupole magnet and two low current solenoids. This trap has a bore diameter of 140mm and tested trap depth of 2.8T. Both low current traps show signs of excessive training. The high current hybrid trap, on the other hand, exhibits good training behavior and is amenable to quench protection.

  10. Research and Development of Nb3Sn Wires and Cables for High-Field Accelerator Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Barzi, Emanuela [Fermilab; Zlobin, Alexander V. [Fermilab

    2016-02-18

    The latest strategic plans for High Energy Physics endorse steadfast superconducting magnet technology R&D for future Energy Frontier Facilities. This includes 10 to 16 T Nb3Sn accelerator magnets for the luminosity upgrades of the Large Hadron Collider and eventually for a future 100 TeV scale proton-proton (pp) collider. This paper describes the multi-decade R&D investment in the Nb3Sn superconductor technology, which was crucial to produce the first reproducible 10 to 12 T accelerator-quality dipoles and quadrupoles, as well as their scale-up. We also indicate prospective research areas in superconducting Nb3Sn wires and cables to achieve the next goals for superconducting accelerator magnets. Emphasis is on increasing performance and decreasing costs while pushing the Nb3Sn technology to its limits for future pp colliders.

  11. Fiber optic quench detection via optimized Rayleigh Scattering in high-field YBCO accelerator magnets

    Energy Technology Data Exchange (ETDEWEB)

    Flanagan, Gene [North Carolina State Univ., Raleigh, NC (United States)

    2016-02-17

    Yttrium barium copper oxide (YBCO) coated conductors are known for their ability to operate in the superconducting state at relatively high temperatures, even above the boiling point of liquid nitrogen (77 K). When these same conductors are operated at lower temperatures, they are able to operate in much higher magnetic fields than traditional superconductors like NiTi or Nb3Sn. Thus, YBCO superconducting magnets are one of the primary options for generating the high magnetic fields needed for future high energy physics devices. Due to slow quench propagation, quench detection remains one of the primary limitations to YBCO magnets. Fiber optic sensing, based upon Rayleigh scattering, has the potential for spatial resolution approaching the wavelength of light, or very fast temporal resolution at low spatial resolution, and a continuum of combinations in between. This project has studied, theoretically and experimentally, YBCO magnets and Rayleigh scattering quench detection systems to demonstrate feasibility of the systems for YBCO quench protection systems. Under this grant an experimentally validated 3D quench propagation model was used to accurately define the acceptable range of spatial and temporal resolutions for effective quench detection in YBCO magnets and to evaluate present-day and potentially improved YBCO conductors. The data volume and speed requirements for quench detection via Rayleigh scattering required the development of a high performance fiber optic based quench detection/data acquisition system and its integration with an existing voltage tap/thermo-couple based system. In this project, optical fibers are tightly co-wound into YBCO magnet coils, with the fiber on top of the conductor as turn-to-turn insulation. Local changes in the temperature or strain of the conductor are sensed by the optical fiber, which is in close thermal and mechanical contact with the conductor. Intrinsic imperfections in the fiber reflect Rayleigh

  12. Development of high field magnets at the National Research Institute for Metals. Kinzoku zairyo gijutsu kenkyusho ni okeru kojikai magnet gun no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Kiyoshi, T.; Inoue, K.; Maeda, H. (National Research Inst. for Metals, Tsukuba (Japan))

    1993-06-20

    Sinece 1988, the Scince and Technology Agency has initiated the superconductor multicore project, which has a purpose of the versatile study on the high temperature superconducting materials of the oxide series. The National Research Institute for Metals is in charge of 5 cores out of them, and in the performance evaluation core which is one of them, the development of each kind of the high field magnets is being advanced for evaluating the characteristics under the high magnetic field. As the magnets, including the 40T class hybrid magnet which generates the steady state magnetic field of 40T, the superconducting magnet of 20T with a large diameter which generates the magnetic field over 20T with a superconductor, the condenser bank system for the pulse magnet to generate the pulse magnetic field up to 80T, and the ultra-precise magnet system which generates the magnetic field with a high uniformity will be consolidated. Keeping pace with a removal of the National Research Institute for Metals to Tsukuba, the construction of the strong magnetic field station is being advanced in the Sakura area. These several kinds of magnets are scheduled to be used in turn for the international joint study. 33 refs., 5 figs., 4 tabs.

  13. High Field Magnetization Studies of Low Dimensional Heisenberg S = 1/2 Antiferromagnets

    Science.gov (United States)

    Landee, C. P.; Turnbull, M. M.

    1998-03-01

    The magnetization curves of a number of low dimensional S=1/2 Heisenberg antiferromagnets have been determined in fields up to 30 tesla at low temperatures at the National High Magnetic Fields Laboratory. Materials studied include a family of 1D materials, based upon Cu(pyrazine)(NO_3)_2, 2D magnets consisting of pyrazine-bridged copper layers, and several spin ladders with singlet ground states. All of the magnetization data show upward curvature and are well described by T = 0 calculations based upon finite cluster models(Bonner and Fisher, Phys. Rev. A135, 640 (1964); Yang and Mutter, NANL cond-mat/9610092.). Chemical substitution on the pyrazine rings permits the variation of exchange constants by more than 25 percent for the family of well isolated chains. The spin ladder systems consist of ferromagnetic dimers weakly connected by antiferromagnetic intradimer interactions. Field induced transitions are seen at fields of less than one tesla for each of the three compounds.

  14. Survey of Processing Methods for High Strength High Conductivity Wires for High Field Magnet Applications

    Energy Technology Data Exchange (ETDEWEB)

    Han, K.; Embury, J.D.

    1998-10-01

    This paper will deal with the basic concepts of attaining combination of high strength and high conductivity in pure materials, in-situ composites and macrocomposites. It will survey current attainments, and outline where some future developments may lie in developing wire products that are close to the theoretical strength of future magnet applications.

  15. Application of Nb3Sn superconductors in high-field accelerator magnets

    NARCIS (Netherlands)

    Ouden, den Andries; Wessel, Sander; Krooshoop, Erik; Kate, ten Herman

    1997-01-01

    Last year a record central field of 11 T at first excitation at 4.4 K has been achieved with the experimental LHC model dipole magnet MSUT by utilising a high Jc powder-in-tube Nb3Sn conductor. This is the first real breakthrough towards fields well above 10 T at 4 K. The clear influence of magnetis

  16. A titanium dioxide filled toroidal coil for magnetic resonance imaging at high field

    Science.gov (United States)

    Butterworth, Edward J.

    1999-09-01

    This study demonstrates the advantages of filling the resonating cavity of a radio frequency NMR coil with a substance that more closely matches the dielectric properties of human tissue. The chosen design is a toroidal RF coil of reduced aspect ratio, and the dielectric material of choice is powdered titanium dioxide. RF coil performance is limited significantly by the dielectric discontinuity and consequent wavelength discontinuity between the air-filled cavity and human tissue. Filling the coil with titanium dioxide (with a published relative dielectric constant of 114 for randomly oriented rutile crystals and a measured dielectric constant under operating conditions of 70) alters its electromagnetic properties in a way which approximates human tissue (most of which has a dielectric constant between 50 and 70), without introducing spurious magnetic effects. In particular, brain NMR can benefit from these advantages. Analytic expressions for the electric and magnetic fields within the coil are derived here. The physical and electromagnetic parameters of the coil are developed with reference to these computations. The redesigned and filled resonator focuses the magnetic field lines, producing a more uniform B1 field as compared with the unfilled coil, with reduced power requirements. The filled coil has a well-defined imaging zone, in which the magnetic field is relatively uniform and homogeneous. The Q of the coil is significantly higher than that of conventional designs and is not significantly reduced by loading. Test results and images are presented showing these effects.

  17. AC loss evaluation of an HTS insert for high field magnet cooled by cryocoolers

    Science.gov (United States)

    Kajikawa, Kazuhiro; Awaji, Satoshi; Watanabe, Kazuo

    2016-12-01

    AC losses in a high temperature superconducting (HTS) insert coil for 25-T cryogen-free superconducting magnet during its initial energization are numerically calculated under the assumption of slab approximation. The HTS insert consisting of 68 single pancakes wound using coated conductors generates a central magnetic field of 11.5 T in addition to the contribution of 14.0 T from a set of low temperature superconducting (LTS) outsert coils. Both the HTS insert and the LTS coils are cooled using cryocoolers, and energized simultaneously up to the central field of 25.5 T with a constant ramp rate for 60 min. The influences of the magnitudes and orientations of locally applied magnetic fields, magnetic interactions between turns and transport currents flowing in the windings are taken into account in the calculations of AC losses. The locally applied fields are separated into axial and radial components, and the individual contributions of these field components to the AC losses are simply summed up to obtain the total losses. The AC losses due to the axial fields become major in the beginning of energization, whereas the total losses monotonically increase with time after the AC losses due to the radial fields become major.

  18. High-field (9.4 T) ~1H magnetic resonance microscopy of mouse brain

    Institute of Scientific and Technical Information of China (English)

    丁广良; 胡红兵; 李丽云; 叶朝辉

    1997-01-01

    The FLASH and STEAM pulse sequences were used to perform the microimaging and localized spectroscopy of brain of living and dead mice, respectively. The phase-shift presaturation approach was used to sup-press water NMR signal. The experimental results show that the differences in localized spectra and MR images of brain between live and dead mice can be observed by means of magnetic resonance microscopy.

  19. Safety of metallic surgical clips in patients undergoing high-field-strength magnetic resonance imaging.

    Science.gov (United States)

    Gold, J P; Pulsinelli, W; Winchester, P; Brill, P W; Jacewicz, M; Isom, O W

    1989-11-01

    Use of metallic clips with ferromagnetic properties in patients undergoing a large variety of surgical procedures, and in particular, in coronary artery and other vascular reconstructions, has become increasingly popular. The safety of these commonly used surgical clips when subjected to high-intensity diagnostic magnetic resonance imaging fields is still debated. Commonly used hemostatic metallic clips manufactured by the Weck and US Surgical Corporations were tested in an in vitro system to assess their safety with regard to migration and displacement. The two tested hemostatic metallic clips proved safe and did not migrate or become dislodged when they underwent magnetic resonance imaging scans. This is in direct contrast to multiple cerebral aneurysm clips, also tested, which have highly ferromagnetic properties and were previously shown to migrate with disastrous results in patients undergoing diagnostic magnetic resonance imaging scans. This study supports the continued widespread use of small metallic hemostatic clips in the myriad of procedures in which they are presently used and illustrates the need for methods of evaluating such devices before they are clinically implanted.

  20. High-field magnetic resonance imaging of brain iron: birth of a biomarker?

    Science.gov (United States)

    Schenck, John F; Zimmerman, Earl A

    2004-11-01

    The brain has an unusually high concentration of iron, which is distributed in an unusual pattern unlike that in any other organ. The physiological role of this iron and the reasons for this pattern of distribution are not yet understood. There is increasing evidence that several neurodegenerative diseases are associated with altered brain iron metabolism. Understanding these dysmetabolic conditions may provide important information for their diagnosis and treatment. For many years the iron distribution in the human brain could be studied effectively only under postmortem conditions. This situation was changed dramatically by the finding that T2-weighted MR imaging at high field strength (initially 1.5 T) appears to demonstrate the pattern of iron distribution in normal brains and that this imaging technique can detect changes in brain iron concentrations associated with disease states. Up to the present time this imaging capability has been utilized in many research applications but it has not yet been widely applied in the routine diagnosis and management of neurodegenerative disorders. However, recent advances in the basic science of brain iron metabolism, the clinical understanding of neurodegenerative diseases and in MRI technology, particularly in the availability of clinical scanners operating at the higher field strength of 3 T, suggest that iron-dependent MR imaging may soon provide biomarkers capable of characterizing the presence and progression of important neurological disorders. Such biomarkers may be of crucial assistance in the development and utilization of effective new therapies for Alzheimer's and Parkinson's diseases, multiple sclerosis and other iron-related CNS disorders which are difficult to diagnose and treat.

  1. Functional magnetic resonance imaging with ultra-high fields; Funktionelle Magnetresonanztomographie bei ultrahohen Feldern

    Energy Technology Data Exchange (ETDEWEB)

    Windischberger, C.; Schoepf, V.; Sladky, R.; Moser, E. [Medizinische Universitaet Wien, Exzellenzzentrum Hochfeld-MR, Wien (Austria); Medizinische Universitaet Wien, Zentrum fuer Medizinische Physik und Biomedizinische Technik, Wien (Austria); Fischmeister, F.P.S. [Medizinische Universitaet Wien, Exzellenzzentrum Hochfeld-MR, Wien (Austria); Universitaet Wien, Fakultaet fuer Psychologie, Wien (Austria)

    2010-02-15

    Functional magnetic resonance imaging (fMRI) is currently the primary method for non-invasive functional localization in the brain. With the emergence of MR systems with field strengths of 4 Tesla and above, neuronal activation may be studied with unprecedented accuracy. In this article we present different approaches to use the improved sensitivity and specificity for expanding current fMRT resolution limits in space and time based on several 7 Tesla studies. In addition to the challenges that arise with ultra-high magnetic fields possible solutions will be discussed. (orig.) [German] Die funktionelle Magnetresonanztomographie (fMRT) stellt zurzeit die wichtigste Methode zur nichtinvasiven Funktionslokalisation im Gehirn dar. Mit der Verfuegbarkeit von MRT-Geraeten mit Magnetfeldstaerken von 4 Tesla (T) und darueber ergeben sich neue Moeglichkeiten, mittels fMRT die neuronale Aktivitaet in bislang unerreichter Genauigkeit zu untersuchen. In diesem Artikel zeigen wir anhand mehrerer Studien bei 7 T, in wieweit die Zugewinne an Sensitivitaet und Spezifitaet verwendet werden koennen, um die bisherigen Grenzen der fMRT-Aufloesung in raeumlicher und zeitlicher Hinsicht auszuweiten. Die neuen Herausforderungen, die mit dem Schritt zu ultrahohen Magnetfeldern einhergehen, werden dabei ebenso diskutiert wie moegliche Ansaetze zu deren Loesung. (orig.)

  2. NMR in pulsed high-field magnets and application to high-T(C) superconductors.

    Science.gov (United States)

    Stork, H; Bontemps, P; Rikken, G L J A

    2013-09-01

    This article deals with the implementation of Nuclear Magnetic Resonance (NMR) experiments in pulsed magnetic fields at the pulsed-field facility of the Laboratoire National des Champs Magnétiques Intenses and its application to the high-T(C) superconductor YBa2Cu3O6.51. The experimental setup is described in detail, including a low-temperature probe head adapted for pulsed fields. An entire paragraph is dedicated to the discussion of NMR in pulsed field and the introduction of an advanced deconvolution technique making use of the induction voltage in an additional pick-up coil. The (63)Cu/(65)Cu NMR experiments on an YBa2Cu3O6.51 single crystal were performed at 2.5K during a field pulse of 46.8-T-amplitude. In the recorded spectrum the (63)Cu center line and high-frequency satellites as well as the (65)Cu center line are identified and are compared with results in literature.

  3. Estimation of the Required Amount of Superconductors for High-field Accelerator Dipole Magnets

    CERN Document Server

    Schwerg, N

    2007-01-01

    The coil size and the corresponding amount of superconducting material that is used during the design process of a magnet cross-section have direct impacts on the overall magnet cost. It is therefore of interest to estimate the minimum amount of conductors needed to reach the defined field strength before a detailed design process starts. Equally, it is useful to evaluate the efficiency of a given design by calculating the amount of superconducting cables that are used to reach the envisaged main field by simple rule. To this purpose, the minimum amount of conductors for the construction of a dipole of given main field strength and aperture size is estimated taking the actual critical current density of the used strands into account. Characteristic curves applicable for the NED Nb3Sn strand specification are given and some of the recently studied different dipole configurations are compared. Based on these results, it is shown how the required amount of conductors changes due to the iron yoke contribution and...

  4. Characterization of a dielectric phantom for high-field magnetic resonance imaging applications

    Energy Technology Data Exchange (ETDEWEB)

    Duan, Qi, E-mail: Qi.Duan@nih.gov; Duyn, Jeff H.; Gudino, Natalia; Zwart, Jacco A. de; Gelderen, Peter van [Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland 20892 (United States); Sodickson, Daniel K.; Brown, Ryan [The Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York 10016 (United States)

    2014-10-15

    Purpose: In this work, a generic recipe for an inexpensive and nontoxic phantom was developed within a range of biologically relevant dielectric properties from 150 MHz to 4.5 GHz. Methods: The recipe includes deionized water as the solvent, NaCl to primarily control conductivity, sucrose to primarily control permittivity, agar–agar to gel the solution and reduce heat diffusivity, and benzoic acid to preserve the gel. Two hundred and seventeen samples were prepared to cover the feasible range of NaCl and sucrose concentrations. Their dielectric properties were measured using a commercial dielectric probe and were fitted to a 3D polynomial to generate a recipe describing the properties as a function of NaCl concentration, sucrose concentration, and frequency. Results: Results indicated that the intuitive linear and independent relationships between NaCl and conductivity and between sucrose and permittivity are not valid. A generic polynomial recipe was developed to characterize the complex relationship between the solutes and the resulting dielectric values and has been made publicly available as a web application. In representative mixtures developed to mimic brain and muscle tissue, less than 2% difference was observed between the predicted and measured conductivity and permittivity values. Conclusions: It is expected that the recipe will be useful for generating dielectric phantoms for general magnetic resonance imaging (MRI) coil development at high magnetic field strength, including coil safety evaluation as well as pulse sequence evaluation (including B{sub 1}{sup +} mapping, B{sub 1}{sup +} shimming, and selective excitation pulse design), and other non-MRI applications which require biologically equivalent dielectric properties.

  5. Comparison of High-field and Low-field Magnetic Resonance Imaging of Stifle Joint Disorders in Dogs.

    Science.gov (United States)

    Przeworski, A; Adamiak, Z; Głodek, J

    2016-09-01

    The most common cause of hindlimb lameness in dogs is cranial cruciate ligament rupture. In 48-77.3% of the population this trauma leads to secondary damage of the meniscus. Depending on the magnetic strength of the used device, different diagnostic accuracy can be achieved. The examination sensitivity of magnetic resonance imaging is affected by many factors which are independent of diagnostic strength, such as correct positioning of the patient, size of the stifle joint examined, or selection of the right protocol of sequences. Sensitivity of meniscus damage detection was 100% and 90%, respectively, in high- and low-field magnetic resonance. The best results were reported during examination of the stifle in dogs above 10 kg b.w. at a flexion angle of 145°, and in sagittal and dorsal planes. Regardless of the magnetic strength applied, imaging of the whole cranial cruciate ligament is difficult. Moreover, MRI allows the detection of the first signs of osteoarthritis, which were observed 4 and 6 weeks after rupture of the cranial cruciate ligament using high and low-field MRI. This also applies to lesions in the subchondral bone or a bone marrow which occurred in association with insufficiency of the stifle joint, and were mainly localized in the epiphysis of the femur and tibia. The present article provides a comparison of different examination protocols and images of damaged stifle structures, such as menisci, ligaments and bones of the stifle joint visualized with low-field and high-field magnetic resonance. Magnetic resonance arthrography is also discussed.

  6. Magnetic resonance imaging of the chest in the evaluation of cancer patients: state of the art

    Directory of Open Access Journals (Sweden)

    Marcos Duarte Guimaraes

    2015-02-01

    Full Text Available Magnetic resonance imaging (MRI has several advantages in the evaluation of cancer patients with thoracic lesions, including involvement of the chest wall, pleura, lungs, mediastinum, esophagus and heart. It is a quite useful tool in the diagnosis, staging, surgical planning, treatment response evaluation and follow-up of these patients. In the present review, the authors contextualize the relevance of MRI in the evaluation of thoracic lesions in cancer patients. Considering that MRI is a widely available method with high contrast and spatial resolution and without the risks associated with the use of ionizing radiation, its use combined with new techniques such as cine-MRI and functional methods such as perfusion- and diffusion-weighted imaging may be useful as an alternative tool with performance comparable or complementary to conventional radiological methods such as radiography, computed tomography and PET/CT imaging in the evaluation of patients with thoracic neoplasias.

  7. Brain-heart interactions: challenges and opportunities with functional magnetic resonance imaging at ultra-high field.

    Science.gov (United States)

    Chang, Catie; Raven, Erika P; Duyn, Jeff H

    2016-05-13

    Magnetic resonance imaging (MRI) at ultra-high field (UHF) strengths (7 T and above) offers unique opportunities for studying the human brain with increased spatial resolution, contrast and sensitivity. However, its reliability can be compromised by factors such as head motion, image distortion and non-neural fluctuations of the functional MRI signal. The objective of this review is to provide a critical discussion of the advantages and trade-offs associated with UHF imaging, focusing on the application to studying brain-heart interactions. We describe how UHF MRI may provide contrast and resolution benefits for measuring neural activity of regions involved in the control and mediation of autonomic processes, and in delineating such regions based on anatomical MRI contrast. Limitations arising from confounding signals are discussed, including challenges with distinguishing non-neural physiological effects from the neural signals of interest that reflect cardiorespiratory function. We also consider how recently developed data analysis techniques may be applied to high-field imaging data to uncover novel information about brain-heart interactions.

  8. Manufacture and Testing of a High Field Gradient Magnetic Fractionation System for Quantitative Detection of Plasmodium falciparum Gametocytes

    Science.gov (United States)

    Karl, Stephan; Woodward, Robert C.; Davis, Timothy M. E.; St. Pierre, Tim G.

    2010-12-01

    Plasmodium falciparum is the most dangerous of the human malaria parasite species and accounts for millions of clinical episodes of malaria each year in tropical countries. The pathogenicity of Plasmodium falciparum is a result of its ability to infect erythrocytes where it multiplies asexually over 48 h or develops into sexual forms known as gametocytes. If sufficient male and female gametocytes are taken up by a mosquito vector, it becomes infectious. Therefore, the presence and density of gametocytes in human blood is an important indicator of human-to-mosquito transmission of malaria. Recently, we have shown that high field gradient magnetic fractionation improves gametocyte detection in human blood samples. Here we present two important new developments. Firstly we introduce a quantitative approach to replace the previous qualitative method and, secondly, we describe a novel method that enables cost-effective production of the magnetic fractionation equipment required to carry out gametocyte quantification. We show that our custom-made magnetic fractionation equipment can deliver results with similar sensitivity and convenience but for a small fraction of the cost.

  9. High field nuclear magnetic resonance in transition metal substituted BaFe{sub 2}As{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Garitezi, T. M., E-mail: thalesmg@ifi.unicamp.br; Lesseux, G. G.; Rosa, P. F. S.; Adriano, C.; Pagliuso, P. G.; Urbano, R. R. [Instituto de Física “Gleb Wataghin,” UNICAMP, Campinas, SP 13083-859 (Brazil); Reyes, A. P.; Kuhns, P. L. [National High Magnetic Field Laboratory, FSU, Tallahassee, Florida 32306-4005 (United States)

    2014-05-07

    We report high field {sup 75}As nuclear magnetic resonance (NMR) measurements on Co and Cu substituted BaFe{sub 2}As{sub 2} single crystals displaying same structural/magnetic transition T{sub 0}≃128  K. From our anisotropy studies in the paramagnetic state, we strikingly found virtually identical quadrupolar splitting and consequently the quadrupole frequency ν{sub Q}≃2.57(1)  MHz for both compounds, despite the claim that each Cu delivers 2 extra 3d electrons in BaFe{sub 2}As{sub 2} compared to Co substitution. These results allow us to conclude that a subtle change in the crystallographic structure, particularly in the Fe–As tetrahedra, must be the most probable tuning parameter to determine T{sub 0} in this class of superconductors rather than electronic doping. Furthermore, our NMR data around T{sub 0} suggest coexistence of tetragonal/paramagnetic and orthorhombic/antiferromagnetic phases between the structural and the spin density wave magnetic phase transitions, similarly to what was reported for K-doped BaFe{sub 2}As{sub 2} [Urbano et al., Phys. Rev. Lett. 105, 107001 (2010)].

  10. Windows on the Human Body – in Vivo High-Field Magnetic Resonance Research and Applications in Medicine and Psychology

    Directory of Open Access Journals (Sweden)

    Ewald Moser

    2010-06-01

    Full Text Available Analogous to the evolution of biological sensor-systems, the progress in “medical sensor-systems”, i.e., diagnostic procedures, is paradigmatically described. Outstanding highlights of this progress are magnetic resonance imaging (MRI and spectroscopy (MRS, which enable non-invasive, in vivo acquisition of morphological, functional, and metabolic information from the human body with unsurpassed quality. Recent achievements in high and ultra-high field MR (at 3 and 7 Tesla are described, and representative research applications in Medicine and Psychology in Austria are discussed. Finally, an overview of current and prospective research in multi-modal imaging, potential clinical applications, as well as current limitations and challenges is given.

  11. Endometrium evaluation with high-field (3-Tesla) magnetic resonance imaging in patients submitted to uterine leiomyoma embolization

    Energy Technology Data Exchange (ETDEWEB)

    Jacobs, Monica Amadio Piazza [Post-graduation Program in Abdominal Imaging, Hospital Israelita Albert Einstein, São Paulo, SP (Brazil); Nasser, Felipe [Intervention Radiology Department, Hospital Israelita Albert Einstein, São Paulo, SP (Brazil); Zlotnik, Eduardo; Messina, Marcos de Lorenzo [Gynecology and Obstetrics Department, Hospital Israelita Albert Einstein, São Paulo, SP (Brazil); Baroni, Ronaldo Hueb [Magnetic Resonance Unit, Imaging Department, Hospital Israelita Albert Einstein, São Paulo, SP (Brazil)

    2013-07-01

    To evaluate the endometrial alterations related to embolization of uterine arteries for the treatment of symptomatic uterine leiomyomatosis (pelvic pain and/or uterine bleeding) by means of high-field (3-Tesla) magnetic resonance. This is a longitudinal and prospective study that included 94 patients with a clinical and imaging diagnosis of symptomatic uterine leiomyomatosis, all of them treated by embolization of the uterine arteries. The patients were submitted to evaluations by high-field magnetic resonance of the pelvis before and 6 months after the procedure. Specific evaluations were made of the endometrium on the T2-weighted sequences, and on the T1-weighted sequences before and after the intravenous dynamic infusion of the paramagnetic contrast. In face of these measures, statistical analyses were performed using Student's t test for comparison of the results obtained before and after the procedure. An average increase of 20.9% was noted in the endometrial signal on T2-weighted images obtained after the uterine artery embolization procedure when compared to the pre-procedure evaluation (p=0.0004). In the images obtained with the intravenous infusion of paramagnetic contrast, an average increase of 18.7% was noted in the post-embolization intensity of the endometrial signal, compared to the pre-embolization measure (p<0.035). After embolization of the uterine arteries, there was a significant increase of the endometrial signal on the T2-weighted images and on the post-contrast images, inferring possible edema and increased endometrial flow. Future studies are needed to assess the clinical impact of these findings.

  12. Preoperative 3T high field blood oxygen level dependent functional magnetic resonance imaging for glioma involving sensory cortical areas

    Institute of Scientific and Technical Information of China (English)

    LI Shao-wu; WANG Jiang-fei; JIANG Tao; LI Shou-wei; ZHANG Wen-bo; LI Zi-xiao; ZHANG Zhong; DAI Jian-ping; WANG Zhong-cheng

    2010-01-01

    Background Localization of sensory cortical areas during the operation is essential to preserve the sensory function.Intraoperative direct electrostimulation under awake anesthesia is the golden standard but time-consuming. We applied 3T high field blood oxygen level-dependent (BOLD) functional magnetic resonance imaging (fMRI) to identify the relationship between glioma and cortical sensory areas preoperatively and to guide intraoperative direct electrostimulation for quick and precise localization.Methods Five glioma patients with sensory cortex involvement by or next to the lesion had preoperative BOLD fMRI to determine the spatial relationship of cortical sensory areas to the tumours. Bilateral hand opposite movement was performed by these patients for fMRI. Precentral and postcentral gyri were identified by electrical stimulation during the operation. Karnofsky Performance Status scores of the patients' pre- and postoperative and the role of BOLD fMRI were evaluated.Results The cortical sensory areas were all activated in five glioma patients involving postcentral gyrus areas by BOLDf MRI with bilateral hand opposite movement. The detected activation areas corresponded with the results from cortical electrical stimulation.Conclusions The relationship between cortical sensory areas and tumour can be accurately shown by BOLD fMRI before operation. And the information used to make the tumour resection could obtain good clinical results.

  13. Functionality of veterinary identification microchips following low- (0.5 tesla) and high-field (3 tesla) magnetic resonance imaging.

    Science.gov (United States)

    Piesnack, Susann; Frame, Mairi E; Oechtering, Gerhard; Ludewig, Eberhard

    2013-01-01

    The ability to read patient identification microchips relies on the use of radiofrequency pulses. Since radiofrequency pulses also form an integral part of the magnetic resonance imaging (MRI) process, the possibility of loss of microchip function during MRI scanning is of concern. Previous clinical trials have shown microchip function to be unaffected by MR imaging using a field strength of 1 Tesla and 1.5. As veterinary MRI scanners range widely in field strength, this study was devised to determine whether exposure to lower or higher field strengths than 1 Tesla would affect the function of different types of microchip. In a phantom study, a total of 300 International Standards Organisation (ISO)-approved microchips (100 each of three different types: ISO FDX-B 1.4 × 9 mm, ISO FDX-B 2.12 × 12 mm, ISO HDX 3.8 × 23 mm) were tested in a low field (0.5) and a high field scanner (3.0 Tesla). A total of 50 microchips of each type were tested in each scanner. The phantom was composed of a fluid-filled freezer pack onto which a plastic pillow and a cardboard strip with affixed microchips were positioned. Following an MRI scan protocol simulating a head study, all of the microchips were accurately readable. Neither 0.5 nor 3 Tesla imaging affected microchip function in this study.

  14. MRI of the Chest

    Medline Plus

    Full Text Available ... of the chest uses a powerful magnetic field, radio waves and a computer to produce detailed pictures ... medical conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed ...

  15. Examination of funnel chests by X-ray and nuclear magnetic resonance tomography: First results and experiences

    Energy Technology Data Exchange (ETDEWEB)

    Raithel, H.J.; Hartung, M.; Gruennewig, B.; Willital, G.

    1983-01-01

    Funnel chest (pectus excavatum) is a congenital malformation of the thorax. Operative correction must presently be regarded as the treatment of choise. In addition to cosmetical and psychological reasons, there are mainly functional aspects justifying a surgery. The indication for surgery results mostly from the objective clinical-diagnostical findings. This article describes the efficiency of both X-ray computerized tomography and also nuclear magnetic resonance tomography (NMR-CAT) which has only recently been introduced to clinical diagnostics.

  16. First studies in the 45 T hybrid magnet at the NHMFL-Tallahassee: the high-field phases of organic and Kondo systems

    Science.gov (United States)

    Brooks, J. S.; Balicas, L.; Tokumoto, M.; Terashima, T.; Echizen, Y.; Takabatake, T.

    2001-01-01

    We have performed magnetoresistance measurements on an organic conductor, α-(BEDT-TTF) 2KHg(SCN) 4, and on a Kondo semiconductor, CeNiSn, at low temperatures and for fields up to 45 T in the hybrid magnet at the National High Magnetic Field Laboratory. We will discuss some new insight into a very controversial high-field phase of α-(BEDT-TTF) 2KHg(SCN) 4 gained from measurements of the anomalous temperature dependence of the quantum oscillations in the range 25-45 T. New information will also be presented on the temperature dependence of resistivity in the high-field state of CeNiSn, where questions of metallic versus semiconducting ground states arise. To acquaint researchers who anticipate using the facility in the near future, practical details concerning use of this new high-field resource are included.

  17. High-field magnetization of heusler alloys Fe2 XY ( X = Ti, V, Cr, Mn, Fe, Co, Ni; Y = Al, Si)

    Science.gov (United States)

    Kourov, N. I.; Marchenkov, V. V.; Korolev, A. V.; Belozerova, K. A.; Weber, H. W.

    2015-10-01

    The magnetization curves of ferromagnetic Heusler alloys Fe2 XY (where X = Ti, V, Cr, Mn, Fe, Co, Ni are transition 3 d elements and Y = Al, Si are the s and p elements of the third period of the Periodic Table) have been measured at T = 4.2 K in the field range H ≤ 70 kOe. It has been shown that the high-field ( H ≥ 20 kOe) magnetization is described within the Stoner model.

  18. A multireader reliability study comparing conventional high-field magnetic resonance imaging with extremity low-field MRI in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Bird, Paul; Ejbjerg, Bo; Lassere, Marissa;

    2007-01-01

    The use of extremity low-field magnetic resonance imaging (E-MRI) is increasing, but relatively few data exist on its reproducibility and accuracy in comparison with high-field MRI, especially for multiple readers. The aim of this multireader exercise of rheumatoid arthritis wrist and metacarpoph...

  19. A multireader reliability study comparing conventional high-field magnetic resonance imaging with extremity low-field MRI in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Bird, Paul; Ejbjerg, Bo; Lassere, Marissa;

    2007-01-01

    The use of extremity low-field magnetic resonance imaging (E-MRI) is increasing, but relatively few data exist on its reproducibility and accuracy in comparison with high-field MRI, especially for multiple readers. The aim of this multireader exercise of rheumatoid arthritis wrist...

  20. Determination of the intersublattice exchange interactions in GdCo12-xFexB6 (x = 0-3) intermetallic compounds by high field magnetization measurements

    Science.gov (United States)

    Diop, L. V. B.; Isnard, O.; Skourski, Y.; Ballon, G.

    2013-05-01

    High field magnetization measurements up to 60 T on free powder samples from GdCo12-xFexB6 (x = 0-3) compounds are reported. The data were used to evaluate the microscopic exchange interaction integral, JGd-3d, between Gd and 3d (Co,Fe) spins. The systems are ferrimagnets; they order magnetically between TC = 95 K for x = 3 and TC = 165 K for x = 0. The low temperature magnetization curves as well as the temperature dependence of intrinsic magnetic parameters are determined by magnetic measurements in pulsed magnetic field. The average magnetic moment ⟨μCo+Fe⟩ per mean transition metal atom (Co + Fe) is small and increases with increasing Fe concentration from 0.44 μΒ for x = 0 to 0.51 μΒ for x = 3 at T = 4 K. From high field magnetization curves, a value of JGd-3d/kB = -4.65 K is derived for x = 0, whereas mean field approximation yields a much larger 3d-3d exchange integral of JCo-Co/kB = 105 K. The obtained results reveal an increase of -JGd-3d/kB with Fe concentration. For x = 0.5, the intersublattice coefficient nGd-3d is found to keep an almost constant value of 5.87 ± 0.13 T*f.u.*μB-1 whatever the temperature in the 2 to 60 K range.

  1. Cardiovascular magnetic resonance of myocardial infarction after blunt chest trauma: a heartbreaking soccer-shot

    Directory of Open Access Journals (Sweden)

    Fogarassy Peter

    2009-10-01

    Full Text Available Abstract Cardiac injury occasionally occurs as a result of blunt chest trauma. Most cardiac complications in chest trauma are due to myocardial contusion rather than direct damage to the coronary arteries. However, traumatic coronary injury has been reported, and a variety of underlying pathophysiological mechanisms have been proposed. We present a 26 year old patient presenting with an acute coronary syndrome as a consequence of a soccer-shot impact to the chest. CMR showed apical inferior infarction, as well as multiple small septal lesions which were presumed to have resulted from embolization. The culprit lesion was a proximal 75% LAD stenosis with a prominent plaque-rupture and thrombus-formation, and the distal LAD was occluded by thromboembolic material.

  2. The connective tissue and ligaments of the distal interphalangeal joint: a review and investigation using ultra-high field 16.4 Tesla magnetic resonance imaging.

    Science.gov (United States)

    Slattery, D; Aland, C; Durbridge, G; Cowin, G

    2014-05-01

    This study reviews the literature on the anatomy of the connective tissues surrounding the distal interphalangeal joint and further characterizes the three-dimensional relationships of these structures with ultra-high field magnetic resonance imaging. Ten cadaver fingers, fixed in a solution of 5% agar and 4% formalin, were imaged utilising an ultrashield 16.4 Tesla ultra-high field magnetic resonance imaging, yielding a total of 4000 images. Images were analysed using Osirix™ (version 5.5.1 32 bit edition) for three-dimensional reconstruction. We found numerous conflicting descriptions of the connective tissue structures around the distal interphalangeal joint. Based upon our literature review and imaging studies we have defined precisely Cleland's ligaments, the oblique proximal septum, Grayson's ligaments, the dorsal plate, and the interosseous ligaments of the distal interphalangeal joint.

  3. Ultra-robust high-field magnetization plateau and supersolidity in bond-frustrated MnCr2S4

    Science.gov (United States)

    Tsurkan, Vladimir; Zherlitsyn, Sergei; Prodan, Lilian; Felea, Viorel; Cong, Pham Thanh; Skourski, Yurii; Wang, Zhe; Deisenhofer, Joachim; von Nidda, Hans-Albrecht Krug; Wosnitza, Joahim; Loidl, Alois

    2017-01-01

    Frustrated magnets provide a promising avenue for realizing exotic quantum states of matter, such as spin liquids and spin ice or complex spin molecules. Under an external magnetic field, frustrated magnets can exhibit fractional magnetization plateaus related to definite spin patterns stabilized by field-induced lattice distortions. Magnetization and ultrasound experiments in MnCr2S4 up to 60 T reveal two fascinating features: (i) an extremely robust magnetization plateau with an unusual spin structure and (ii) two intermediate phases, indicating possible realizations of supersolid phases. The magnetization plateau characterizes fully polarized chromium moments, without any contributions from manganese spins. At 40 T, the middle of the plateau, a regime evolves, where sound waves propagate almost without dissipation. The external magnetic field exactly compensates the Cr–Mn exchange field and decouples Mn and Cr sublattices. In analogy to predictions of quantum lattice-gas models, the changes of the spin order of the manganese ions at the phase boundaries of the magnetization plateau are interpreted as transitions to supersolid phases. PMID:28345038

  4. Terahertz cyclotron resonance spectroscopy of an AlGaN/GaN heterostructure using a high-field pulsed magnet and an asynchronous optical sampling technique

    Science.gov (United States)

    Spencer, B. F.; Smith, W. F.; Hibberd, M. T.; Dawson, P.; Beck, M.; Bartels, A.; Guiney, I.; Humphreys, C. J.; Graham, D. M.

    2016-05-01

    The effective mass, sheet carrier concentration, and mobility of electrons within a two-dimensional electron gas in an AlGaN/GaN heterostructure were determined using a laboratory-based terahertz cyclotron resonance spectrometer. The ability to perform terahertz cyclotron resonance spectroscopy with magnetic fields of up to 31 T was enabled by combining a high-field pulsed magnet with a modified asynchronous optical sampling terahertz detection scheme. This scheme allowed around 100 transmitted terahertz waveforms to be recorded over the 14 ms magnetic field pulse duration. The sheet density and mobility were measured to be 8.0 × 1012 cm-2 and 9000 cm2 V-1 s-1 at 77 K. The in-plane electron effective mass at the band edge was determined to be 0.228 ± 0.002m0.

  5. A portable high-field pulsed-magnet system for single-crystal x-ray scattering studies.

    Science.gov (United States)

    Islam, Zahirul; Ruff, Jacob P C; Nojiri, Hiroyuki; Matsuda, Yasuhiro H; Ross, Kathryn A; Gaulin, Bruce D; Qu, Zhe; Lang, Jonathan C

    2009-11-01

    We present a portable pulsed-magnet system for x-ray studies of materials in high magnetic fields (up to 30 T). The apparatus consists of a split-pair of minicoils cooled on a closed-cycle cryostat, which is used for x-ray diffraction studies with applied field normal to the scattering plane. A second independent closed-cycle cryostat is used for cooling the sample to near liquid helium temperatures. Pulsed magnetic fields (approximately 1 ms in total duration) are generated by discharging a configurable capacitor bank into the magnet coils. Time-resolved scattering data are collected using a combination of a fast single-photon counting detector, a multichannel scaler, and a high-resolution digital storage oscilloscope. The capabilities of this instrument are used to study a geometrically frustrated system revealing strong magnetostrictive effects in the spin-liquid state.

  6. Use of movable high-field-strength intraoperative magnetic resonance imaging with awake craniotomies for resection of gliomas: preliminary experience.

    LENUS (Irish Health Repository)

    Leuthardt, Eric C

    2011-07-01

    Awake craniotomy with electrocortical mapping and intraoperative magnetic resonance imaging (iMRI) are established techniques for maximizing tumor resection and preserving function, but there has been little experience combining these methodologies.

  7. [Comparative assessment of MR-semiotics of acutest intracerebral hematomas in low- and extra high-field frequency magnetic resonance tomography].

    Science.gov (United States)

    Skvortsova, V I; Burenchev, D V; Tvorogova, T V; Guseva, O I; Prokhorov, A V; Smirnov, A M; Kupriianov, D A; Pirogov, Iu A

    2009-01-01

    An objective of the study was to compare sensitivity of low- and extra high-field frequency magnetic resonance (MR) tomography of acutest intracerebral hematomas (ICH) and to assess differences between symptoms in obtained images. A study was conducted using experimental ICH in rats (n=6). Hematomas were formed by two injections of autologic blood into the brain. MR-devices "Bio Spec 70/30" with magnetic field strength of 7 T and "Ellipse-150" with magnetic field strength of 0,15 T were used in the study. MR-tomography was carried out 3-5 h after the injections. Both MR-devices revealed the presence of pathological lesion in all animals. Extra highfield frequency MR-tomography showed the specific signs of ICH caused by the paramagnetic effect of deoxyhemoglobin in T2 and T2*-weighted images (WI) and low frequency MR-tomography - in T2*-WI only. The comparable sensitivity of low- and extra high-field frequency MR-devices in acutest ICH was established.

  8. Neutron diffraction study of anomalous high-field magnetic phases in TmNi2B2C

    DEFF Research Database (Denmark)

    Toft, K.N.; Abrahamsen, A.B.; Eskildsen, M.R.;

    2004-01-01

    .483,0,0), and Q(AII)=(0.496,0,0), all with the magnetic moment along the c axis. In zero and low fields the Tm 4f-moments order in a long wavelength transverse spin density wave with Q=Q(F). The magnetic Q(AI) structure is stabilized by an applied field of 1 T and a transition to Q(AII) is observed at 4 T......We present a (B,T)-phase diagram of the magnetic superconductor TmNi2B2C obtained by neutron scattering. The measurements were performed in magnetic fields up to 6 T applied along the crystalline a axis. The observed phases are characterized by three ordering vectors, Q(F)=(0.094,0.094,0),Q(AI)=(0.......90Yb0.10)Ni2B2C the Q(F)-->Q(AI) phase transition is also observed but at a larger transition field compared to the undoped compound. In (Tm0.85Yb0.15)Ni2B2C the Q(F) phase persists up to at least 1.8 T. The magnetic correlation length of the Q(AI) phase in TmNi2B2C measured parallel and perpendicular...

  9. Cardiothoracic ratio on chest radiograph in pediatric heart disease: How does it correlate with heart volumes at magnetic resonance imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Grotenhuis, Heynric B. [The University of Toronto, Division of Cardiology, Department of Paediatrics, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto (Canada); Zhou, Cheng; Isaac, Kathryn V. [The University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto (Canada); Tomlinson, George [University of Toronto, Department of Medicine, Toronto General Hospital and Mt. Sinai Hospital, Toronto (Canada); Seed, Mike; Grosse-Wortmann, Lars; Yoo, Shi-Joon [The University of Toronto, Division of Cardiology, Department of Paediatrics, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto (Canada); The University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto (Canada)

    2015-10-15

    The cardiothoracic ratio by chest radiograph is widely used as a marker of cardiac size. The purpose of this study is to correlate cardiothoracic ratio and cardiac volumes as measured by cardiovascular magnetic resonance (MR) in common structural and myopathic heart disease with increased cardiac size due to volume overload or hypertrophy. A retrospective single center study was performed in all patients between 2007 and 2013 with repaired tetralogy of Fallot (TOF), aortic regurgitation, isolated left-to-right shunt and hypertrophic cardiomyopathy (HCM) who underwent cardiovascular MR and chest radiograph within 6 months of each other. Cardiothoracic ratios by chest radiograph (frontal and lateral) were compared to cardiac volumes (indexed for body surface area) by cardiovascular MR. One hundred twenty-seven patients (mean age: 11.2 ± 5.5 years) were included in this study (76 with TOF, 23 with isolated left-to-right shunt, 16 with aortic regurgitation and 12 with HCM). Frontal cardiothoracic ratio of all groups correlated with indexed right ventricular (RV) end-diastolic volume (EDVI) (r = 0.40, P < 0.01) and indexed total heart volume (THVI) (r = 0.27, P < 0.01). In TOF patients, frontal cardiothoracic ratio correlated with RVEDVI (r = 0.34, P < 0.01; coefficient of variation = 27.6%), indexed RV end-systolic volume (ESVI) (r = 0.44, P < 0.01; coefficient of variation = 33.3%) and THVI (r = 0.35, P < 0.01; coefficient of variation = 19.6%), although RV volumes and THVI showed widespread variation given the high coefficients of variation. In patients with aortic regurgitation, frontal cardiothoracic ratio correlated with left ventricular (LV) EDVI (r = 0.50, P = 0.047), but not with THVI and aortic regurgitant fraction, and widespread variation for LV EDVI (coefficient of variation = 19.2%), LV ESVI (coefficient of variation = 32.5%) and THVI (coefficient of variation = 13.6%) was also observed. Frontal cardiothoracic ratio was not correlated with cardiac volumes

  10. High field magnetic transitions in the mixed holmium-yttrium iron garnet Ho(0.43)Y(2.57)Fe(5)O(12).

    Science.gov (United States)

    Bouguerra, A; Khène, S; de Brion, S; Chouteau, G; Fillion, G

    2005-01-12

    High static magnetic field magnetization measurements have been performed up to 23 T on Ho(0.43)Y(2.57)Fe(5)O(12) single crystals at helium temperature (T = 4.2 K) with fields applied along the three main cubic axes: [Formula: see text], [Formula: see text] and [Formula: see text]. The change from the spontaneous ferrimagnetic structure in zero magnetic field to the fully ferromagnetic one in high field takes place through several intermediate phases separated by transitions with step-like magnetization behaviour, but without any observed hysteresis. Using the effective spin Hamiltonian approximation, we show that the general features of these transitions can be accounted for by a large magnetocristalline anisotropy of the Ho(3+) moments of the uniaxial type along the local z axis of each rare-earth site. The model is in better agreement with the experiments than its Ising limit, widely used before, but is still unsuccessful in predicting the 'umbrella' magnetic structures found by previous neutron and NMR experiments.

  11. ARC: A compact, high-field, fusion nuclear science facility and demonstration power plant with demountable magnets

    Energy Technology Data Exchange (ETDEWEB)

    Sorbom, B.N., E-mail: bsorbom@mit.edu; Ball, J.; Palmer, T.R.; Mangiarotti, F.J.; Sierchio, J.M.; Bonoli, P.; Kasten, C.; Sutherland, D.A.; Barnard, H.S.; Haakonsen, C.B.; Goh, J.; Sung, C.; Whyte, D.G.

    2015-11-15

    Highlights: • ARC reactor designed to have 500 MW fusion power at 3.3 m major radius. • Compact, simplified design allowed by high magnetic fields and jointed magnets. • ARC has innovative plasma physics solutions such as inboardside RF launch. • High temperature superconductors allow high magnetic fields and jointed magnets. • Liquid immersion blanket and jointed magnets greatly simplify tokamak reactor design. - Abstract: The affordable, robust, compact (ARC) reactor is the product of a conceptual design study aimed at reducing the size, cost, and complexity of a combined fusion nuclear science facility (FNSF) and demonstration fusion Pilot power plant. ARC is a ∼200–250 MWe tokamak reactor with a major radius of 3.3 m, a minor radius of 1.1 m, and an on-axis magnetic field of 9.2 T. ARC has rare earth barium copper oxide (REBCO) superconducting toroidal field coils, which have joints to enable disassembly. This allows the vacuum vessel to be replaced quickly, mitigating first wall survivability concerns, and permits a single device to test many vacuum vessel designs and divertor materials. The design point has a plasma fusion gain of Q{sub p} ≈ 13.6, yet is fully non-inductive, with a modest bootstrap fraction of only ∼63%. Thus ARC offers a high power gain with relatively large external control of the current profile. This highly attractive combination is enabled by the ∼23 T peak field on coil achievable with newly available REBCO superconductor technology. External current drive is provided by two innovative inboard RF launchers using 25 MW of lower hybrid and 13.6 MW of ion cyclotron fast wave power. The resulting efficient current drive provides a robust, steady state core plasma far from disruptive limits. ARC uses an all-liquid blanket, consisting of low pressure, slowly flowing fluorine lithium beryllium (FLiBe) molten salt. The liquid blanket is low-risk technology and provides effective neutron moderation and shielding, excellent

  12. Preliminary Observations on Sensitivity and Specificity of Magnetization Transfer Asymmetry for Imaging Myelin of Rat Brain at High Field.

    Science.gov (United States)

    Kim, Jae-Woong; Choi, Jiye; Cho, Janggeun; Lee, Chulhyun; Jeon, Daejong; Park, Sung-Hong

    2015-01-01

    Magnetization transfer ratio (MTR) has been often used for imaging myelination. Despite its high sensitivity, the specificity of MTR to myelination is not high because tissues with no myelin such as muscle can also show high MTR. In this study, we propose a new magnetization transfer (MT) indicator, MT asymmetry (MTA), as a new method of myelin imaging. The experiments were performed on rat brain at 9.4 T. MTA revealed high signals in white matter and significantly low signals in gray matter and muscle, indicating that MTA has higher specificity than MTR. Demyelination and remyelination studies demonstrated that the sensitivity of MTA to myelination was as high as that of MTR. These experimental results indicate that MTA can be a good biomarker for imaging myelination. In addition, MTA images can be efficiently acquired with an interslice MTA method, which may accelerate clinical application of myelin imaging.

  13. The design of the inelastic neutron scattering mode for the Extreme Environment Diffractometer with the 26 T High Field Magnet

    Energy Technology Data Exchange (ETDEWEB)

    Bartkowiak, Maciej, E-mail: maciej.bartkowiak@helmholtz-berlin.de; Stüßer, Norbert; Prokhnenko, Oleksandr

    2015-10-11

    The Extreme Environment Diffractometer is a neutron time-of-flight instrument, designed to work with a constant-field hybrid magnet capable of reaching fields over 26 T, unprecedented in neutron science; however, the presence of the magnet imposes both spatial and technical limitations on the surrounding instrument components. In addition to the existing diffraction and small-angle neutron scattering modes, the instrument will operate also in an inelastic scattering mode, as a direct time-of-flight spectrometer. In this paper we present the Monte Carlo ray-tracing simulations, the results of which illustrate the performance of the instrument in the inelastic-scattering mode. We describe the focussing neutron guide and the chopper system of the existing instrument and the planned design for the instrument upgrade. The neutron flux, neutron spatial distribution, divergence distribution and energy resolution are calculated for standard instrument configurations.

  14. ARC: A compact, high-field, fusion nuclear science facility and demonstration power plant with demountable magnets

    CERN Document Server

    Sorbom, B N; Palmer, T R; Mangiarotti, F J; Sierchio, J M; Bonoli, P; Kasten, C; Sutherland, D A; Barnard, H S; Haakonsen, C B; Goh, J; Sung, C; Whyte, D G

    2014-01-01

    The affordable, robust, compact (ARC) reactor conceptual design study aims to reduce the size, cost, and complexity of a combined fusion nuclear science facility (FNSF) and demonstration fusion Pilot power plant. ARC is a 270 MWe tokamak reactor with a major radius of 3.3 m, a minor radius of 1.1 m, and an on-axis magnetic field of 9.2 T. ARC has rare earth barium copper oxide (REBCO) superconducting toroidal field coils, which have joints to enable disassembly. This allows the vacuum vessel to be replaced quickly, mitigating first wall survivability concerns, and permits a single device to test many vacuum vessel designs and divertor materials. The design point has a plasma fusion gain of Q_p~13.6, yet is fully non-inductive, with a modest bootstrap fraction of only ~63%. Thus ARC offers a high power gain with relatively large external control of the current profile. This highly attractive combination is enabled by the ~23 T peak field on coil with newly available REBCO superconductor technology. External cu...

  15. Three-dimensional reconstructed magnetic resonance imaging for diagnosing persistent left superior vena cava. Comparison with magnetic resonance angiography and plain chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Koito, Hitoshi; Suzuki, Junichi; Ohkubo, Naohiko; Ishiguro, Yuka; Iwasaka, Toshiji; Inada, Mitsuo; Nakano, Yoshihisa [Kansai Medical Univ., Moriguchi, Osaka (Japan)

    1996-09-01

    The usefulness of low-cost, three-dimensional (3D) images reconstructed from magnetic resonance (MR) imaging for investigating persistent left superior vena cava was assessed and compared to the diagnostic accuracy of chest radiography. MR imaging by the spin-echo technique and MR angiography were performed in 10 patients with this anomaly diagnosed previously by contrast echocardiography and radionuclide angiocardiography. Four patients had complicating cardiac anomalies, one with postoperative atrial septal defect, one with postoperative ventricular septal defect, one with atrial septal defect and partial anomalous pulmonary venous return, and one with aortic coarctation and patent ductus arteriosus. Multisectional and multiphasic MR images were used for the 3D-reconstruction of the cardiovascular and mediastinal structures with a NeXT workstation and a 3D-kit. The 3D-reconstructed MR imaging clearly showed the persistent left superior vena cava and the anatomical relationship with the other cardiovascular and mediastinal structures in all 10 patients. Vascular shadows were observed outside the upper left border of the aortic arch on the chest radiographs in seven patients, and the 3D-reconstructed MR images revealed these shadows to be compatible with superior caval vein. The ratios of the diameter between the left and right superior venae cavae with and without the left innominate vein were 0.63{+-}0.14 (mean{+-}SD) and 0.94{+-}0.08, respectively. Three-dimensional reconstructed MR imaging is a useful method for recognizing persistent left superior vena cava and precise examination of the chest radiographs often allowed detection of the vascular shadows caused by this anomaly. (author)

  16. High field magnetic resonance microscopy of the human hippocampus in Alzheimer's disease: quantitative imaging and correlation with iron.

    Science.gov (United States)

    Antharam, Vijay; Collingwood, Joanna F; Bullivant, John-Paul; Davidson, Mark R; Chandra, Saurav; Mikhaylova, Albina; Finnegan, Mary E; Batich, Christopher; Forder, John R; Dobson, Jon

    2012-01-16

    We report R(2) and R(2) in human hippocampus from five unfixed post-mortem Alzheimer's disease (AD) and three age-matched control cases. Formalin-fixed tissues from opposing hemispheres in a matched AD and control were included for comparison. Imaging was performed in a 600MHz (14T) vertical bore magnet at MR microscopy resolution to obtain R(2) and R(2) (62 μm×62 μm in-plane, 80 μm slice thickness), and R(1) at 250 μm isotropic resolution. R(1), R(2) and R(2) maps were computed for individual slices in each case, and used to compare subfields between AD and controls. The magnitudes of R(2) and R(2) changed very little between AD and control, but their variances in the Cornu Ammonis and dentate gyrus were significantly higher in AD compared for controls (piron and MRI parameters, each tissue block was cryosectioned at 30 μm in the imaging plane, and iron distribution was mapped using synchrotron microfocus X-ray fluorescence spectroscopy. A positive correlation of R(2) and R(2)* with iron was demonstrated. While studies with fixed tissues are more straightforward to conduct, fixation can alter iron status in tissues, making measurement of unfixed tissue relevant. To our knowledge, these data represent an advance in quantitative imaging of hippocampal subfields in unfixed tissue, and the methods facilitate direct analysis of the relationship between MRI parameters and iron. The significantly increased variance in AD compared for controls warrants investigation at lower fields and in-vivo, to determine if this parameter is clinically relevant.

  17. High field magnetization processes in single crystals of alpha-Tb{sub 2}S{sub 3} and alpha-Dy{sub 2}S{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Ebisu, S; Omote, H; Nagata, S [Department of Materials Science and Engineering, Muroran Institute of Technology, 27-1 Mizumoto-cho, Muroran, Hokkaido 050-8585 (Japan); Koyama, K, E-mail: ebisu@mmm.muroran-it.ac.j [HFLSM, Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan)

    2009-03-01

    Rare earth sesquisulfides alpha-Tb{sub 2}S{sub 3} and alpha-Dy{sub 2}S{sub 3} possess orthorhombic crystal structure having two independent rare earth sites. High field magnetization processes for single crystals of these compounds have been investigated up to mu{sub o}H = 18 T. Some step-like transitions have been observed in both compounds. The magnetization of alpha-Tb{sub 2}S{sub 3} single crystal under the field along the 6-axis at T = 1.4 K shows a steep increase of about 4.5 mu{sub B}, which corresponds to a half of full saturation moment of free Tb{sup 3+}, at mu{sub o}H = 2.2 T. It is considered that the reorientation of Tb{sup 3+} moments on only one Tb site into a ferromagnetic arrangement occurs. When the magnetic field is perpendicular to the b-axis, one-step transition at mu{sub o}H = 0.7 T for H||c and two-step transitions at 0.7 and 1.2 T for H||a are observed. As for alpha-Dy{sub 2}S{sub 3}, the magnetization curve at T = 1.5 K shows two-step transitions at 1.3 and 1.6 T (H||b), three or four dull steps (H||a or c). The total height of two steps in the M-H curve for H||b corresponds to a half of full Dy{sup 3+} moment.

  18. High-field open versus short-bore magnetic resonance imaging of the spine: a randomized controlled comparison of image quality.

    Directory of Open Access Journals (Sweden)

    Judith Enders

    Full Text Available BACKGROUND: The purpose of the present study was to compare the image quality of spinal magnetic resonance (MR imaging performed on a high-field horizontal open versus a short-bore MR scanner in a randomized controlled study setup. METHODS: Altogether, 93 (80% women, mean age 53 consecutive patients underwent spine imaging after random assignement to a 1-T horizontal open MR scanner with a vertical magnetic field or a 1.5-T short-bore MR scanner. This patient subset was part of a larger cohort. Image quality was assessed by determining qualitative parameters, signal-to-noise (SNR and contrast-to-noise ratios (CNR, and quantitative contour sharpness. RESULTS: The image quality parameters were higher for short-bore MR imaging. Regarding all sequences, the relative differences were 39% for the mean overall qualitative image quality, 53% for the mean SNR values, and 34-37% for the quantitative contour sharpness (P<0.0001. The CNR values were also higher for images obtained with the short-bore MR scanner. No sequence was of very poor (nondiagnostic image quality. Scanning times were significantly longer for examinations performed on the open MR scanner (mean: 32±22 min versus 20±9 min; P<0.0001. CONCLUSIONS: In this randomized controlled comparison of spinal MR imaging with an open versus a short-bore scanner, short-bore MR imaging revealed considerably higher image quality with shorter scanning times. TRIAL REGISTRATION: ClinicalTrials.gov NCT00715806.

  19. [Chest trauma].

    Science.gov (United States)

    Freixinet Gilart, Jorge; Ramírez Gil, María Elena; Gallardo Valera, Gregorio; Moreno Casado, Paula

    2011-01-01

    Chest trauma is a frequent problem arising from lesions caused by domestic and occupational activities and especially road traffic accidents. These injuries can be analyzed from distinct points of view, ranging from consideration of the most severe injuries, especially in the context of multiple trauma, to the specific characteristics of blunt and open trauma. In the present article, these injuries are discussed according to the involvement of the various thoracic structures. Rib fractures are the most frequent chest injuries and their diagnosis and treatment is straightforward, although these injuries can be severe if more than three ribs are affected and when there is major associated morbidity. Lung contusion is the most common visceral lesion. These injuries are usually found in severe chest trauma and are often associated with other thoracic and intrathoracic lesions. Treatment is based on general support measures. Pleural complications, such as hemothorax and pneumothorax, are also frequent. Their diagnosis is also straightforward and treatment is based on pleural drainage. This article also analyzes other complex situations, notably airway trauma, which is usually very severe in blunt chest trauma and less severe and even suitable for conservative treatment in iatrogenic injury due to tracheal intubation. Rupture of the diaphragm usually causes a diaphragmatic hernia. Treatment is always surgical. Myocardial contusions should be suspected in anterior chest trauma and in sternal fractures. Treatment is conservative. Other chest injuries, such as those of the great thoracic and esophageal vessels, are less frequent but are especially severe.

  20. Ultra high field magnetic resonance imaging; L'imagerie par resonance magnetique a ultra-haut champ. L'aimant, piece maitresse de l'imageur. Memo C: les principales techniques d'imagerie medicale

    Energy Technology Data Exchange (ETDEWEB)

    Lethimonnier, F. [CEA Saclay, Institut d' Imagerie Biomedicale - NeuroSpin, Dir. des Sciences du Vivant, 91 - Gif-sur-Yvette (France); Vedrine, P. [CEA Saclay, Direction des Sciences de la Matiere, 91 - Gif-sur-Yvette (France)

    2008-07-01

    Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ultra-high-field system of unprecedented power that is designed for research on human subjects. The level of the magnetic field and the scale required will make this joint French-German project to build the magnet a breakthrough in the international arena. (authors)

  1. Assessment of age-related morphometric changes of subcortical structures in healthy people using ultra-high field 7 tesla magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Xueyuan Wang

    2016-09-01

    Full Text Available Objective: To assess the age-related morphometric changes of subcortical structures in healthy people.Material and Methods: Ultra-high field 7 tesla magnetic resonance imaging in humans was used to visualize the subcortical structures of healthy young, middle-aged, and elderly participants. Using the magnetization-prepared two rapid acquisition gradient echoes sequence, we assessed the visibility of the margins of the thalamus and white matter in the thalamus, as well as the anterior commissure (AC and posterior commissure (PC length, the maximal height of the thalamus, the half width of third ventricle, and the distance between the AC and the center of the mammillothalamic tract at the level of the AC-PC plane. All quantitative data were statistically evaluated.Results: The AC-PC length did not differ significantly among the three groups. The maximal height of the thalamus decreased with age (rs(53=-0.719, p<0.001. The half width of the third ventricle (rs(53=0.705, p<0.001 and the distance between the AC and the center of the mammillothalamic tract (MTT (rs(53=0.485, p<0.001 increased with age. The distance between the AC and the center of the MTT of the young and the elderly participants differed significantly (p=0.007.Conclusion: The AC-PC length is not a good candidate for proportional correction during atlas-to-patient registration. The maximal height of the thalamus and the half width of the third ventricle correlated strongly with age, and the MTT position in relation to the AC shifted posteriorly as age increased. These age-related morphometric changes of subcortical structures should be considered in targeting for functional neurosurgery.

  2. Chemical spray pyrolysis of Tl-Ba-Ca-Cu-O high-T(sub c) superconductors for high-field bitter magnets

    Science.gov (United States)

    Derochemont, L. Pierre; Zhang, John G.; Squillante, Michael R.; Hermann, A. M.; Duan, H. M.; Andrews, Robert J.; Kelliher, Warren C.

    1991-01-01

    The deposition of Tl-Ba-Ca-Cu-O thick films by spray pyrolyzing a Ba-Ca-Cu-O precursor film and diffusing thallium into the film to form the superconducting phase is examined. This approach was taken to reduce exposure to thallium and its health and safety hazards. The Tl-Ba-Ca-Cu-O system was selected because it has very attractive features which make it appealing to device and manufacturing engineering. Tl-Ba-Ca-Cu-O will accommodate a number of superconducting phases. This attribute makes it very forgiving to stoichiometric fluctuations in the bulk and film. It has excellent thermal and chemical stability, and appears to be relatively insensitive to chemical impurities. Oxygen is tightly bound into the systems, consequently there is no orthorhombic (conductor) to tetragonal (insulator) transition which would affect a component's lifetime. More significantly, the thallium based superconductors appear to have harder magnetic properties than the other high-Tc oxide ceramics. Estimates using magnetoresistance measurements indicate that at 77 K Tl2Ba2CaCu2O10 will have an upper critical field, H(sub c2) fo 26 Tesla for applied fields parallel to the c-axis and approximately 1000 Tesla for fields oriented in the a-b plane. Results to date have shown that superconducting films can be reproducibly deposited on 100 oriented MgO substrates. One film had a zero resistance temperature of 111.5 K. Furthermore, x ray diffraction analysis of the films showed preferential c-axis orientation parallel to the plane of the substrate. These results have now made it possible to consider the manufacture of a superconducting tape wire which can be configured into a topology useful for high-field magnet designs. The research which leads to the preparation of these films and plans for further development are reviewed.

  3. The Travelling-Wave Primate System: A New Solution for Magnetic Resonance Imaging of Macaque Monkeys at 7 Tesla Ultra-High Field.

    Directory of Open Access Journals (Sweden)

    Tim Herrmann

    Full Text Available Neuroimaging of macaques at ultra-high field (UHF is usually conducted by combining a volume coil for transmit (Tx and a phased array coil for receive (Rx tightly enclosing the monkey's head. Good results have been achieved using vertical or horizontal magnets with implanted or near-surface coils. An alternative and less costly approach, the travelling-wave (TW excitation concept, may offer more flexible experimental setups on human whole-body UHF magnetic resonance imaging (MRI systems, which are now more widely available. Goal of the study was developing and validating the TW concept for in vivo primate MRI.The TW Primate System (TWPS uses the radio frequency shield of the gradient system of a human whole-body 7 T MRI system as a waveguide to propagate a circularly polarized B1 field represented by the TE11 mode. This mode is excited by a specifically designed 2-port patch antenna. For receive, a customized neuroimaging monkey head receive-only coil was designed. Field simulation was used for development and evaluation. Signal-to-noise ratio (SNR was compared with data acquired with a conventional monkey volume head coil consisting of a homogeneous transmit coil and a 12-element receive coil.The TWPS offered good image homogeneity in the volume-of-interest Turbo spin echo images exhibited a high contrast, allowing a clear depiction of the cerebral anatomy. As a prerequisite for functional MRI, whole brain ultrafast echo planar images were successfully acquired.The TWPS presents a promising new approach to fMRI of macaques for research groups with access to a horizontal UHF MRI system.

  4. High-field magnetic resonance imaging of the developing human brain from the 10th to the 16th week of gestational Age.

    Science.gov (United States)

    Sbarbati, A; Marzola, P; Simonati, A; Nicolato, E; Osculati, F

    1998-01-01

    In the present work, high-field magnetic resonance imaging (HF-MRI) was applied to study the developing human brain paying particular attention to the structures of interest in pathology of malformation. The aim of the work was to evaluate the possible application of HF-MRI to the analysis of brain development in the absence of some limits of conventional histological technique. Seven formalin-fixed human fetuses of 50, 65, 70, 85, 110, 116 and 125 mm crown/ rump length (corresponding to a gestational age ranging from 10 to 16 weeks) were examined in an imager-spectrometer equipped with a 4. 7-tesla horizontal magnet with a 33-cm bore. In the brain of all the fetuses the telencephalic, mesencephalic and rhombencephalic vesicles were recognizable and an easy quantitative evaluation of the brain curvatures in the absence of distortion due to dissection was possible. Comparing fetuses at different gestational ages, the spatial modification of the different vesicles was evident. In fetuses at 16 weeks of gestational age, stratified compartments of the telencephalic wall were evident. The germinal zone and the cortical plate were visible: the germinal layer was identifiable as a hypointensity in the periventricular area. The subplate zone and the intermediate zone emitted a strong intensity signal. Our study demonstrates that HF-MRI can contribute to the study of the complex developmental events in the human brain from the 10th to 16th week of gestational age in a submillimetric scale of resolution. This technique can provide information about the morphology of the encephalic vesicles and their relations with the bone cavity that cannot be obtained with conventional methods and may be a useful adjunct to histological techniques.

  5. A high-field magnetic resonance imaging spectrometer using an oven-controlled crystal oscillator as the local oscillator of its radio frequency transceiver.

    Science.gov (United States)

    Liang, Xiao; Tang, Xin; Tang, Weinan; Gao, Jia-Hong

    2014-09-01

    A home-made high-field magnetic resonance imaging (MRI) spectrometer with multiple receiving channels is described. The radio frequency (RF) transceiver of the spectrometer consists of digital intermediate frequency (IF) circuits and corresponding mixing circuits. A direct digital synthesis device is employed to generate the IF pulse; the IF signal from a down-conversion circuit is sampled and followed by digital quadrature detection. Both the IF generation and the IF sampling use a 50 MHz clock. An oven-controlled crystal oscillator, which has outstanding spectral purity and a compact circuit, is used as the local oscillator of the RF transceiver. A digital signal processor works as the pulse programmer of the spectrometer, as a result, 32 control lines can be generated simultaneously while an event is triggered. Field programmable gate array devices are utilized as the auxiliary controllers of the IF generation, IF receiving, and gradient control. High performance, including 1 μs time resolution of the soft pulse, 1 MHz receiving bandwidth, and 1 μs time resolution of the gradient waveform, is achieved. High-quality images on a 1.5 T MRI system using the spectrometer are obtained.

  6. Role of high-field intraoperative magnetic resonance imaging on a multi-image fusion-guided stereotactic biopsy of the basal ganglia: A case report.

    Science.gov (United States)

    Sun, Xiang; Chen, Zhijuan; Yang, Shuyuan; Zhang, Jianning; Yue, Shuyuan; Wang, Zengguang; Yang, Weidong

    2015-01-01

    The aim of the present case study was to investigate the advantages of intraoperative magnetic resonance imaging (iMRI) on the real-time guidance and monitoring of a stereotactic biopsy. The study describes a patient with intracranial lesions, which were examined by conventional MRI and diffusion tensor imaging using a 1.5T intraoperative MRI system. The digital and pre-operative positron emission/computed tomography image data were transferred to a BrainLAB planning workstation, and a variety of images were automatically fused. The BrainLAB software was then used to reconstruct the corticospinal tract (CST) and create a three-dimensional display of the anatomical association between the CST and the brain lesions. A Leksell surgical planning workstation was used to identify the ideal target site and a reasonable needle track for the biopsy. The 1.5T iMRI was used to effectively monitor the intracranial condition during the brain biopsy procedure. Post-operatively, the original symptoms of the patient were not aggravated and no further neurological deficits were apparent. The histopathological diagnosis of non-Hodgkin's B-cell lymphoma was made. Using high-field iMRI, the multi-image fusion-guided stereotactic brain biopsy allows for a higher positive rate of biopsy and a lower incidence of complications. The approach of combining multi-image fusion images with the frame-based stereotactic biopsy may be clinically useful for intracranial lesions of deep functional areas.

  7. Processing and characterization of superconducting solenoids made of Bi-2212/Ag-alloy multifilament round wire for high field magnet applications

    Science.gov (United States)

    Chen, Peng

    As the only high temperature superconductor with round wire (RW) geometry, Bi2Sr2CaCu2O8+x (Bi-2212) superconducting wire has the advantages of being multi-filamentary, macroscopically isotropic and twistable. With overpressure (OP) processing techniques recently developed by our group at the National High Magnetic Field Laboratory (NHMFL), the engineering current density (Je) of Bi-2212 RW can be dramatically increased. For example, Je of more than 600 A/mm 2 (4.2 K and 20 T) is achieved after 100 bar OP processing. With these intrinsically beneficial properties and recent processing progress, Bi-2212 RW has become very attractive for high field magnet applications, especially for nuclear magnetic resonance (NMR) magnets and accelerator magnets etc. This thesis summarizes my graduate study on Bi-2212 solenoids for high field and high homogeneity NMR magnet applications, which mainly includes performance study of Bi-2212 RW insulations, 1 bar and OP processing study of Bi-2212 solenoids, and development of superconducting joints between Bi-2212 RW conductors. Electrical insulation is one of the key components of Bi-2212 coils to provide sufficient electrical standoff within coil winding pack. A TiO 2/polymer insulation offered by nGimat LLC was systematically investigated by differential thermal analysis (DTA), thermo-gravimetric analysis (TGA), scanning electron microscopy (SEM), dielectric property measurements, and transport critical current (Ic) property measurements. About 29% of the insulation by weight is polymer. When the Bi-2212 wire is fully heat treated, this decomposes with slow heating to 400 °C in flowing O2. After the full reaction, we found that the TiO2 did not degrade the critical current properties, adhered well to the conductor, and provided a breakdown voltage of more than 100 V. A Bi-2212 RW wound solenoid coil was built using this insulation being offered by nGimat LLC. The coil resistance was constant through coil winding, polymer burn

  8. Chest Pain

    Directory of Open Access Journals (Sweden)

    Samad Shams-Vahdati

    2014-03-01

    Full Text Available Introduction: Acute chest pain is an important and frequently occurring symptom in patients. Chest pain is often a sign of ischemic heart disease. Associated findings of electrocardiograph (ECG are rather heterogeneous, and traditional cardiac biomarkers such as Creatine Kinase-MB (CK-MB suffer from low cardiac specificity and sensitivity. In this study cost effectiveness of cardiac biomarkers single quantitative measurement was examined.Methods: The present descriptive-analytic study conducted on patients who were asked for troponin I and CK-MB. All patients who referred to Emergency unit of Tabriz Imam Reza educational-medical center during January 2012 to July the 2013 were included in study. All patients included in the study were documented in terms of age, sex, working shift of referring, main complaint of patient, symptoms in referring, ECG findings, and results of troponin I and CK-MB tests.Results: In this study, 2900 patients were studied including 1440 (49.7% males and 1460 (50.3% females. Mean age of patients was 62.91 (SD=14.36. Of all patients 1880 (64.8% of patients referred during 8 a.m. to 8 p.m. and 1020 (35.2% patients were referred during 8 p.m. to 8 a.m. The sensitivity of cardiac biomarkers’ test in diagnosing Acute Coronary Syndrome (ACS disease was calculated as 44.8% and its specificity was 86.6%. For diagnosing Acute Myocardial Infarction (AMI, sensitivity of cardiac biomarkers’ test was 72.2% and its specificity was 86%. None of patients who were finally underwent unstable angina diagnosis showed increase in cardiac enzymes.Conclusion: In conclusion, cardiac biomarkers can be used for screening acute chest pains, also cost effectiveness of cardiac biomarkers, appropriate specificity and sensitivity can guarantee their usefulness in emergency room.

  9. Magnetic resonance imaging of hindfoot involvement in patients with spondyloarthritides: Comparison of low-field and high-field strength units

    Energy Technology Data Exchange (ETDEWEB)

    Eshed, Iris; Althoff, Christian E. [Department of Radiology, Charite Medical School, Berlin (Germany); Feist, Eugen [Department of Rheumatology and Clinical Immunology, Charite Medical School, Berlin (Germany); Minden, Kirsten [Helios Clinics, 2nd Children' s Hospital Berlin-Buch, Rheumatology Unit, Berlin (Germany); German Rheumatology Research Center, Berlin (Germany); Schink, Tania [Department of Medical Biometry, Charite Medical School, Berlin (Germany); Hamm, Bernd [Department of Radiology, Charite Medical School, Berlin (Germany); Hermann, Kay-Geert A. [Department of Radiology, Charite Medical School, Berlin (Germany)], E-mail: kgh@charite.de

    2008-01-15

    Objective: To compare MRI evaluation of a painful hindfoot of patients with spondyloarthritides (SpA) on low-field (0.2 T) versus high-field (1.5 T) MRI. Materials and methods: Patients with SpA and hindfoot pain were randomly referred to either high-field or low-field MRI. Twenty-seven patients were evaluated (male/female: 17:10; mean age: 39 {+-} 1.4 years). Fifteen patients were examined by low-field and 12 by high-field MRI. Two patients (evaluated by high-field MRI) were excluded. Images were separately read by two radiologists who later reached a consensus. In each patient the prevalence of erosions, fluid, synovitis or bone marrow edema of the hindfoot joints, tendinosis or tenosynovitis of tendons, enthesitis of the plantar fascia and Achilles tendon and retrocalcaneal bursitis were recorded. Clinical and demographic parameters were comparable between both groups. Results: MRI evaluation of joints and tendons of the hindfoot revealed no significant differences in patients with SpA groups for all parameters. Analyzing all joints or tendons together, there was no statistically significant difference between the two groups. Conclusion: Low-field and high-field MRI provide comparable information for evaluation of inflammatory hindfoot involvement. Thus, low-field MRI can be considered as a reliable diagnostic tool for the detection of hindfoot abnormalities in SpA patients.

  10. Persistence of singlet fluctuations in the coupled spin tetrahedra system Cu2Te2O5Br2 revealed by high-field magnetization, 79Br NQR, and 125Te NMR

    Science.gov (United States)

    Baek, S.-H.; Choi, K.-Y.; Berger, H.; Büchner, B.; Grafe, H.-J.

    2012-11-01

    We present high-field magnetization and 79Br nuclear quadrupole resonance (NQR) and 125Te nuclear magnetic resonance (NMR) studies in the weakly coupled Cu2+ (S=1/2) tetrahedral system Cu2Te2O5Br2. The field-induced level crossing effects were observed by the magnetization measurements in a long-ranged magnetically ordered state which was confirmed by a strong divergence of the spin-lattice relaxation rate T1-1 at T0=13.5 K. In the paramagnetic state, T1-1 reveals an effective singlet-triplet spin gap much larger than that observed by static bulk measurements. Our results imply that the inter- and the intratetrahedral interactions compete, but at the same time they cooperate strengthening effectively the local intratetrahedral exchange couplings. We discuss that the unusual feature originates from the frustrated intertetrahedral interactions.

  11. Chest radiation - discharge

    Science.gov (United States)

    Radiation - chest - discharge; Cancer - chest radiation; Lymphoma - chest radiation ... When you have radiation treatment for cancer, your body goes through changes. About 2 weeks after your first treatment: It may be hard ...

  12. Chest X Ray?

    Science.gov (United States)

    ... this page from the NHLBI on Twitter. Chest X Ray A chest x ray is a fast and painless imaging test ... tissue scarring, called fibrosis. Doctors may use chest x rays to see how well certain treatments are ...

  13. Pseudoaneurysm of the mitral–aortic intervalvular fibrosa presenting after chest trauma and diagnosed by cardiac magnetic resonance: a case report

    Directory of Open Access Journals (Sweden)

    Barranhas Adriana

    2012-10-01

    Full Text Available Abstract Introduction Annular subvalvular pseudoaneurysm is a rare example of left ventricle aneurysm described predominantly in young African people. These aneurysms are divided into two different types, namely, submitral or subaortic, with subaortic being the less frequent kind. The subaortic type is most often localized in the mitral–aortic intervalvular fibrosa. To the best of our knowledge, this is the first report of a mitral–aortic intervalvular fibrosa pseudoaneurysm associated with coarctation of the aorta, anomalous pulmonary venous return, bicuspid aortic valve and patent ductus arteriosus diagnosed by cardiovascular magnetic resonance. Case presentation We report the case of a 15-year-old African-American boy with a history of mild chest trauma who underwent echocardiographic evaluation as part of an out-patient work up. The echocardiogram was suspicious for the presence of mitral-aortic intervalvular fibrosa pseudoaneurysm and cardiovascular magnetic resonance was then performed to better characterize this finding. In addition to confirming the presence of the aneurysm, cardiovascular magnetic resonance also revealed coarctation of the aorta, a bicuspid aortic valve, and anomalous pulmonary venous return. Conclusion In our case, cardiovascular magnetic resonance was helpful in: (a making a definite diagnosis of mitral–aortic intervalvular fibrosa pseudoaneurysm and its borders, which was not clear with an echocardiogram examination; and (b illustrating additional associated congenital anomalies including the anomalous pulmonary venous return.

  14. High field superconducting magnet: Science, Technology and Applications%高场超导磁体科学技术与应用

    Institute of Scientific and Technical Information of China (English)

    王秋良

    2013-01-01

    科学技术的发展对于磁场强度质量的要求越来越高,极端强磁场条件是人类追求的永远的科学目标,它孕育着许多重大的科学发现和新技术的产生,对人类的科学和技术以及生活产生重大的影响.以磁体为核心与电力电子器件以及相关的软件等结合可以构成各种各样科学仪器和装置,广泛应用在科学研究和工业特种装备中.磁技术对于人类的科学与技术进步起到越来越重要的作用,尤其是极高磁场所带来的诸多优点,使得人类对于物质世界认识不断加深,对于生命的起源以及从事疾病的防治的研究有特别重要的意义.本文介绍磁体基本原理、磁场产生的方法与应用以及相关的发展.%Development of superconducting magnet science and technology requires a magnetic field with high strength and good quality.The pursuit of extremely high magnetic field is an eternal scientific goal forscientists and engineers.It is an exciting cutting-edge technology with full of challenges and has been essential for many significant discoveries in science and technology.Combined with power-electronic devices and related software,a whole magnet system can be built up as the key component of various types of scientific instruments and other equipment,and can be fund widespread applications in scientific research and industry.Magnet technology is currently playing a more and more important role in scientific and technological progress.Ultra-high magnetic fields help to give us much deeper understanding of the world of matter and have special significance for research into the origins of life and disease prevention.In this review article,basic magnet principles,methods of generating magnetic fields,magnetic field applications,and numerical methods for the design of magnet structures are briefly introduced and reviewed.

  15. Band-Structure Effects in the High-Field Magnetization of Pd and Dilute Pd-Rh and Pd-Ag Alloys

    DEFF Research Database (Denmark)

    Andersen, O. Krogh

    1970-01-01

    be derived solely from the band density of states N(E). The previously reported Pd band-structure calculations, which were in excellent agreement with the de Haas-van Alphen data, have been extended to yield DeltaB(sigma) for Pd and, using the rigid band model, also for dilute Pd[Single Bond]Rh and Pd......From Stoner theory we show that the magnetic field-vs-spin magnetization has the form B(sigma)=sigma/chi(0)+DeltaB(sigma). The low-field susceptibility chi(0) is exchange-enhanced but, if the effective exchange potential does not depend on magnetization, the deviation from linearity DeltaB may......; moreover, the experimental data have previously been analyzed according to a power series expansion of sigma(B) that neither separates the effect of band structure from that of exchange enhancement nor applies when van Hove singularities are important. Our formulation suggests a way of analyzing...

  16. Magnetic, high-field EPR studies and catalytic activity of Schiff base tetranuclear CuII2FeIII2 complexes obtained by direct synthesis.

    Science.gov (United States)

    Nesterova, Oksana V; Chygorin, Eduard N; Kokozay, Vladimir N; Bon, Volodymyr V; Omelchenko, Irina V; Shishkin, Oleg V; Titiš, Ján; Boča, Roman; Pombeiro, Armando J L; Ozarowski, Andrew

    2013-12-28

    Two novel heterometallic complexes [Cu2Fe2(HL(1))2(H2L(1))2]·10DMSO (1) and [Cu2Fe2(HL(2))2(H2L(2))2]·2DMF (2) have been prepared using the open-air reaction of copper powder, iron(II) chloride and DMSO (1) or DMF (2) solutions of the polydentate Schiff base (H4L(1), 1; H4L(2), 2) formed in situ from salicylaldehyde (1) or 5-bromo-salicylaldehyde (2) and tris(hydroxymethyl)aminomethane. Crystallographic analysis revealed that both compounds are based on the centrosymmetric tetranuclear core {Cu(II)2Fe(III)2(μ-O)6} where metal centres are joined by μ-O bridges from the deprotonated ligands forming a nonlinear chain-like arrangement. Variable-temperature (1.8-300 K) magnetic susceptibility measurements of 1 and 2 showed a decrease of the effective magnetic moment value at low temperature, indicative of antiferromagnetic coupling (JCu-Fe/hc = -10.2 cm(-1), JFe-Fe/hc = -10.5 cm(-1) in 1, JCu-Fe/hc = -10.5 cm(-1), JFe-Fe/hc = -8.93 cm(-1) in 2) between the magnetic centres in both compounds. They reveal an exceptionally high catalytic activity in the oxidation of cyclohexane with hydrogen peroxide under mild conditions, with the best observed yield/TON combined values of 36%/596 and 44%/1.1 × 10(3) for 1 and 2, respectively.

  17. High-field magnetic resonance imaging of structural alterations in first-episode, drug-naive patients with major depressive disorder.

    Science.gov (United States)

    Chen, Z; Peng, W; Sun, H; Kuang, W; Li, W; Jia, Z; Gong, Q

    2016-11-08

    Previous structural imaging studies have found evidence of brain morphometric changes in patients with major depressive disorder (MDD), but these studies rarely excluded compounding effects of certain important factors, such as medications and long duration of illnesses. Furthermore, the neurobiological mechanism of the macroscopic findings of structural alterations in MDD patients remains unclear. In this study, we utilized magnetization transfer imaging, a quantitative measure of the macromolecular structural integrity of brain tissue, to identify biophysical alterations, which are represented by a magnetization transfer ratio (MTR), in MDD patients. To ascertain whether MTR changes occur independent of volume loss, we also conduct voxel-based morphometry (VBM) analysis. The participants included 27 first-episode, drug-naive MDD patients and 28 healthy controls matched for age and gender. Whole-brain voxel-based analysis was used to compare MTR and gray matter volume across groups and to analyse correlations between MTR and age, symptom severity, and illness duration. The patients exhibited significantly lower MTR in the left superior parietal lobule and left middle occipital gyrus compared with healthy controls, which may be related to the attentional and cognitive dysfunction in MDD patients. The VBM analysis revealed significantly increased gray matter volume in right postcentral gyrus in MDD patients. These findings in first-episode, drug-naive MDD patients may reflect microstructural gray matter changes in the parietal and occipital cortices close to illness onset that existed before volume loss, and thus potentially provide important new insight into the early neurobiology of depression.

  18. Chest X-Ray

    Medline Plus

    Full Text Available ... breath, persistent cough, fever, chest pain or injury. It may also be useful to help diagnose and ... have some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to ...

  19. Management of flail chest.

    OpenAIRE

    Miller, H A; Taylor, G.A.; Harrison, A. W.; Maggisano, R.; Hanna, S.; de Lacy, J. L.; Shulman, H.

    1983-01-01

    This paper compares the management of two groups of patients with flail chest. The 25 patients in group 1 had a flail chest without other significant injuries or shock, whereas the 57 in group 2 had a flail chest with multiple injuries, shock or both. The group 1 patients were treated with repeated multiple intercostal nerve blocks or high segmental epidural analgesia, oxygen, intensive chest physiotherapy, fluid restriction, furosemide diuretics, methylprednisolone sodium succinate and collo...

  20. Specific proof of various stages of Osler's disease of the brain via high field magnetic resonance tomography (1. 5 Tesla)

    Energy Technology Data Exchange (ETDEWEB)

    Billet, F.; Bluemm, R.G.; Beyer, H.K.

    1988-08-01

    MR is a sensitive noninvasive examination method for diagnosing parenchymatous cryptic arteriovenous malformations and sequels of cerebral haemorrhage. In a patient with recurring nosebleed and brain stem syndrome eleven so-called cryptic arteriovenous malformations or their haemorrhage sequels were diagnosed via magnetic resonance tomography. Basing on these specific findings, nosebleeding, and a positive family anamnesis, the findings could be classified as belonging to manifestations of Osler's disease (hereditary haemorrhagic telangiectasia). This rare disease is characterised by a triad of signs: telangiectasias, recurring bleeding, and heredity. In this article the specific MR image is compared with the CT pattern and the results are discussed against the background of literature on Osler's disease which is also known as Rendu-Osler-Weber disease.

  1. Atomic scale structure of amorphous aluminum oxyhydroxide, oxide and oxycarbide films probed by very high field (27)Al nuclear magnetic resonance.

    Science.gov (United States)

    Baggetto, L; Sarou-Kanian, V; Florian, P; Gleizes, A N; Massiot, D; Vahlas, C

    2017-03-15

    The atomic scale structure of aluminum in amorphous alumina films processed by direct liquid injection chemical vapor deposition from aluminum tri-isopropoxide (ATI) and dimethyl isopropoxide (DMAI) is investigated by solid-state (27)Al nuclear magnetic resonance (SSNMR) using a very high magnetic field of 20.0 T. This study is performed as a function of the deposition temperature in the range 300-560 °C, 150-450 °C, and 500-700 °C, for the films processed from ATI, DMAI (+H2O), and DMAI (+O2), respectively. While the majority of the films are composed of stoichiometric aluminum oxide, other samples are partially or fully hydroxylated at low temperature, or contain carbidic carbon when processed from DMAI above 500 °C. The quantitative analysis of the SSNMR experiments reveals that the local structure of these films is built from AlO4, AlO5, AlO6 and Al(O,C)4 units with minor proportions of the 6-fold aluminum coordination and significant amounts of oxycarbides in the films processed from DMAI (+O2). The aluminum coordination distribution as well as the chemical shift distribution indicate that the films processed from DMAI present a higher degree of structural disorder compared to the films processed from ATI. Hydroxylation leads to an increase of the 6-fold coordination resulting from the trend of OH groups to integrate into AlO6 units. The evidence of an additional environment in films processed from DMAI (+O2) by (27)Al SSNMR and first-principle NMR calculations on Al4C3 and Al4O4C crystal structures supports that carbon is located in Al(O,C)4 units. The concentration of this coordination environment strongly increases with increasing process temperature from 600 to 700 °C favoring a highly disordered structure and preventing from crystallizing into γ-alumina. The obtained results are a valuable guide to the selection of process conditions for the CVD of amorphous alumina films with regard to targeted applications.

  2. American College of Chest Physicians

    Science.gov (United States)

    ... Master Fellows Staff & Contact Us CHEST Newsroom Staff Job Opportunities at CHEST Contact Us Industry Support Industry Support ... of Global Governors Master Fellows CHEST Newsroom Staff Job Opportunities at CHEST Contact Us Industry Support Industry Advisory ...

  3. Magnetic resonance-guided upper abdominal biopsies in a high-field wide-bore 3-T MRI system: feasibility, handling, and needle artefacts

    Energy Technology Data Exchange (ETDEWEB)

    Kuehn, Jens-Peter; Langner, Soenke; Hegenscheid, Katrin; Hosten, Norbert; Puls, Ralf [Ernst Moritz Arndt University of Greifswald, Department of Radiology, Greifswald (Germany); Evert, Matthias [Ernst Moritz Arndt University of Greifswald, Department of Pathology, Greifswald (Germany); Kickhefel, Antje [Siemens Healthcare, Erlangen (Germany)

    2010-10-15

    To investigate the feasibility and handling of abdominal MRI-guided biopsies in a 3-T MRI system. Over a 1-year period, 50 biopsies were obtained in 47 patients with tumours of the upper abdominal organs guided by 3-T MRI with a large-bore diameter of 70 cm. Lesions in liver (47), spleen (1) and kidney (2) were biopsied with a coaxial technique using a 16-G biopsy needle guided by a T1-weighted three-dimensional gradient recalled echo volumetric interpolated breath-hold examination (T1w-3D-GRE-VIBE) sequence. Sensitivity, specificity, accuracy, complication rate, interventional complexity, room/intervention time and needle artefacts were determined. A sensitivity of 0.93, specificity of 1.0 and accuracy of 0.94 were observed. Three patients required a rebiopsy. There was a minor complications rate of 13.6%, and no major complications were observed. Histopathology revealed 38 malignant lesions, and 3-month follow-up confirmed 9 benign lesions. Mean lesion diameter was 3.4 {+-} 3.1 cm (50% being smaller than 2 cm). Mean needle tract length was 10.8 {+-} 3.3 cm. Median room time was 42.0 {+-} 19.8 min and intervention time 9.3 {+-} 8.1 min. Needle artefact size was about 9-fold greater for perpendicular access versus access parallel to the main magnetic field. Biopsies of the upper abdomen can be performed with great technical success and easy handling because of the large-bore diameter. The MRI-guided biopsy needle had an acceptable susceptibility artefact at 3 T. However future research must aim to reduce the susceptibility effects of the biopsy systems. (orig.)

  4. High-field magnetization of a two-dimensional spin frustration system, Ni{sub 5}(TeO{sub 3}){sub 4}X{sub 2} (X = Br, Cl)

    Energy Technology Data Exchange (ETDEWEB)

    Her, J L; Matsuda, Y H; Suga, K; Kindo, K; Takeyama, S [Institute for Solid State Physics, University of Tokyo (Japan); Berger, H [Institutes of Physics of Complex Matter, EPFL, Lausanne (Switzerland); Yang, H D [Department of Physics, Center for Nanoscience and Nanotechnology, National Sun Yat-sen University, Taiwan (China)

    2009-10-28

    The high-field magnetization, M(H), of Ni{sub 5}(TeO{sub 3}){sub 4}X{sub 2} (X = Br, Cl) was measured by using a pulse magnet. These compounds have a two-dimensional crystal structure and a distorted Kagome spin frustrated system which is built from the Ni{sup 2+} ions (S = 1). The Neel transition temperatures are T{sub N}approx28 and 23 K for X = Br and Cl, respectively. When TT{sub N}, the field-dependent magnetization curves behave like a monotonically increasing straight line up to 55 T. The H{sub c} value is close to those obtained in previous spin resonance studies in which a model of a spin-flop scenario was proposed to explain the field-dependent resonance spectra. With the earlier model a further transition at around 23 T was predicted; however, our observations did not show any plateau behaviors, saturation or other anomalies up to 55 T, suggesting that the further transition possibly exists in a much higher field region.

  5. High-field phase transitions and Fermi surfaces in the organic conductor α-(BEDT-TTF) 2KHg(SCN) 4: Influence of the magnetic breakdown on evaluation of the effective mass and the scattering time

    Science.gov (United States)

    Sasaki, T.; Biberacher, W.; Fukase, T.

    1998-05-01

    The change of the de Haas-van Alphen (dHvA) oscillation between the low-field spin-density-wave (SDW) phase and the high-field ( H⩾23 T) metallic phase of the organic conductor α-(BEDT-TTF) 2KHg(SCN) 4 is explained in terms of a model of the magnetic breakdown (MB) and a reconstructed Fermi surface by SDW. On the reconstructed Fermi surface, the scattering time obtained by fitting the standard Lifshitz-Kosevich formulation to the dHvA oscillations is affected by the MB giving the additional field-dependent effect. Furthermore, the evaluation of the effective mass needs to consider the additional temperature-dependent factor being due to the MB gap which may change intrinsically and/or thermally with temperature.

  6. High field magnetotransport and point contact Andreev reflection measurements on CuCr{sub 2}Se{sub 4} and CuCr{sub 2}Se{sub 3}Br—Degenerate magnetic semiconductor single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Borisov, K., E-mail: borisovk@tcd.ie; Coey, J. M. D.; Stamenov, P. [School of Physics and CRANN, Trinity College, Dublin 2 (Ireland); Alaria, J. [Department of Physics, University of Liverpool, Liverpool L69 7ZE (United Kingdom)

    2014-05-07

    Single crystals of the metallically degenerate fully magnetic semiconductors CuCr{sub 2}Se{sub 4} and CuCr{sub 2}Se{sub 3}Br have been prepared by the Chemical Vapour Transport method, using either Se or Br as transport agents. The high-quality, millimetre-sized, octahedrally faceted, needle- and platelet-shaped crystals are characterised by means of high field magnetotransport (μ{sub 0}H≤ 14 T) and Point Contact Andreev Reflection. The relatively high spin polarisation observed |P|>0.56, together with the relatively low minority carrier effective mass of 0.25 m{sub e}, and long scattering time  10{sup −13} s, could poise these materials for integration in low- and close-to-room temperature minority injection bipolar heterojunction transistor demonstrations.

  7. Tuberculous spondylitis presenting as severe chest pain

    Directory of Open Access Journals (Sweden)

    Martha A. Kaeser

    2012-04-01

    Full Text Available This case report describes a 32-year-old male who presented to an emergency department with severe chest pain and a history of cough, fever, night sweats, loss of appetite and weight. Chest radiography revealed a left upper lobe consolidation and multiple compression deformities in the thoracic spine. Magnetic resonance imaging demonstrated significant kyphosis and vertebral plana at two thoracic levels. Anterior compression of the spinal cord and adjacent soft tissue masses were also noted.

  8. Antenna development for high field plasma imaging.

    Science.gov (United States)

    Kong, X; Domier, C W; Luhmann, N C

    2010-10-01

    Electron cyclotron emission imaging (ECEI) and microwave imaging reflectometry (MIR) are two microwave nonperturbing plasma visualization techniques that employ millimeter-wave imaging arrays with lens-coupled planar antennas, yielding time-resolved images of temperature (via ECEI) and electron density (via MIR) fluctuations within high temperature magnetic fusion plasmas. A series of new planar antennas have been developed that extend this technology to frequencies as high as 220 GHz for use on high field plasma devices with toroidal fields in excess of 3 T. Antenna designs are presented together with theoretical calculations, simulations, and experimental measurements.

  9. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    Clinical trials for the treatment of cystic fibrosis (CF) lung disease are important to test and optimize new therapeutic interventions. To evaluate the effect of these interventions, sensitive and accurate outcome measures are needed. The most commonly used endpoints are spirometric variables...... are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  10. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Johnsen, Karen Kirstine; Thomsen, Henrik

    2015-01-01

    on collimation and dose reduction in digital chest radiography Methods and Materials A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from one hundred fifty self-reliant female patients between 15 and 55 years...... collimations depending on side of radiograph. Results from dose reduction will be presented on the congress Conclusion: Correct positioning and collimation of digital chest radiographs can reduce the radiation dose significant to the patients and by that improve the quality of basic radiography....

  11. Chest tube insertion - slideshow

    Science.gov (United States)

    ... presentations/100008.htm Chest tube insertion - series—Normal anatomy To use the sharing features ... pleural space is the space between the inner and outer lining of the lung. It is normally very thin, and lined only ...

  12. MRI of the Chest

    Medline Plus

    Full Text Available ... primarily used to assess abnormal masses such as cancer and determine the size, extent and degree of ... chest is performed to: assess abnormal masses, including cancer of the lungs or other tissues, which either ...

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... detailed pictures of the structures within the chest. It is primarily used to assess abnormal masses such ... and determine the size, extent and degree of its spread to adjacent structures. It’s also used to ...

  14. Neonatal Chest Wall Rhabdomyosarcoma.

    Science.gov (United States)

    Feldman, Michael; Steiner, Zvi; Groisman, Gabriel; Nadir, Erez

    2015-06-01

    An infant was born at term with a huge chest mass diagnosed as rhabdomyosarcoma. Treatment consisted of surgical resection and chemotherapy. We describe this very rare congenital mass and the problematic therapeutic management of such a tumor in a newborn.

  15. Neonatal Chest Wall Rhabdomyosarcoma

    OpenAIRE

    Feldman, Michael; Steiner, Zvi; Groisman, Gabriel; Nadir, Erez

    2015-01-01

    An infant was born at term with a huge chest mass diagnosed as rhabdomyosarcoma. Treatment consisted of surgical resection and chemotherapy. We describe this very rare congenital mass and the problematic therapeutic management of such a tumor in a newborn.

  16. Cardiac injuries in blunt chest trauma

    Directory of Open Access Journals (Sweden)

    Tobon-Gomez Catalina

    2009-09-01

    Full Text Available Abstract Blunt chest traumas are a clinical challenge, both for diagnosis and treatment. The use of Cardiovascular Magnetic Resonance can play a major role in this setting. We present two cases: a 12-year-old boy and 45-year-old man. Late gadolinium enhancement imaging enabled visualization of myocardial damage resulting from the trauma.

  17. The Project for the New High Field Facility

    OpenAIRE

    Motokawa, M.

    1996-01-01

    Since High Field Laboratory for Superconducting Materials attached to Institute for Materials Research of Tohoku University started, 15 years has passed. We have had plenty of fruitful scientific and technological results not only in a field of superconductivity but also in areas of magnetism, semiconductors, organic conductors, chemical and biological materials and crystallography. The equipments in the Laboratory, however, are now getting aged and the available high field of 31 T obtained b...

  18. CHEST PHYSIOTHERAPY FOR INFANTS

    Directory of Open Access Journals (Sweden)

    Preeti S. Christian (M.P.T Cardiopulmonary Conditions

    2014-10-01

    Full Text Available In the normal lung, secretions are removed by Mucociliary activity, normal breathing cycles, and cough. In disease, increased secretion viscosity and volume, dyskinesia of the cilia, and ineffective cough combine to reduce the ability to clear secretions, and may increase exacerbations and infections. Many chest physiotherapy techniques like postural drainage, percussion and vibration are used since many years. These techniques are derived from adult studies but these techniques are quite stressful for the infants as the infant respiratory system is different from the adult respiratory system. Advance chest physiotherapy techniques were developed specifically for infants; in accordance with their physiological characteristics. So this review is to introduce some new chest physiotherapy helpful for newborn infants.

  19. Acute diaphragmatic paralysis caused by chest-tube trauma to phrenic nerve

    Energy Technology Data Exchange (ETDEWEB)

    Nahum, E.; Ben-Ari, J.; Schonfeld, T. [Pediatric Intensive Care Unit, Schneider Children' s Medical Center of Israel, Petah Tiqva (Israel); Horev, G. [Dept. of Diagnostic Radiology, Schneider Children' s Medical Center of Israel, Petah Tiqva (Israel); Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel)

    2001-06-01

    A 3{sup 1}/{sub 2}-year-old child developed unilateral diaphragmatic paralysis after chest drain insertion. Plain chest X-ray demonstrated paravertebral positioning of the chest-tube tip, and magnetic resonance imaging revealed hematomas in the region of the chest-tube tip and the phrenic nerve fibers. The trauma to the phrenic nerve was apparently secondary to malposition of the chest tube. This is a rare complication and has been reported mainly in neonates. Radiologists should notify the treating physicians that the correct position of a chest drain tip is at least 2 cm distant from the vertebrae. (orig.)

  20. Imaging of Chest Wall Lesions in Children

    Directory of Open Access Journals (Sweden)

    A. Hekmatnia

    2008-01-01

    Full Text Available Chest wall lesions in childhood include a wide range of pathologies; Benign lesions include lipoma, neurofibroma, lymphangioma, hemangioma, and mesenchymal hamartoma."nMalignant lesions include Neuroblastoma, Rhabdo-myosarcoma, Ewing sarcoma, and Askin tumor."nSystemic diseases such as leukemia, lymphoma, Langerhans cell histiocytosis, and also infections such as tuberculosis, and actinomycosis may also cause chest wall lesions."nThe imaging characteristics of these lesions are re-viewed, but only a minority of the lesions shows diagnostic imaging features, and most of lesions re-quire biopsy and histopathological examination for "ndefinitive diagnosis."nThe role of different modalities is discussed with an emphasis on magnetic resonance imaging for demonstrating lesion morphology and local spread. Computed tomography and neuclear medicine being used mainly to assess remote disease."nIn this lecture, we discuss about imaging of chest wall lesions in children.

  1. Anterior chest wall examination reviewed

    Directory of Open Access Journals (Sweden)

    F. Trotta

    2011-09-01

    Full Text Available Anterior chest wall involvement is not infrequently observed within inflammatory arthropaties, particularly if one considers seronegative spondiloarthritides and SAPHO syndrome. Physical examination is unreliable and conventional X-rays analysis is an unsatisfactory tool during diagnostic work-up of this region. Scintigraphic techniques yield informations both on the activity and on the anatomical extent of the disease while computerized tomography visualize the elementary lesions, such as erosions, which characterize the process. Moreover, when available, magnetic resonance imaging couple the ability to finely visualize such lesions with the possibility to show early alterations and to characterize the “activity” of the disease, presenting itself as a powerful tool both for diagnosis and follow-up. This review briefly shows the applications of imaging techniques for the evaluation of the anterior chest wall focusing on what has been done in the SAPHO syndrome which can be considered prototypical for this regional involvement since it is the osteo-articular target mainly affected by the disease.

  2. MRI of the Chest

    Medline Plus

    Full Text Available ... vertebrae, ribs and sternum) and chest wall soft tissue (muscles and fat). assess for pericardial (thin sac around the heart) disease. characterize mediastinal or pleural lesions seen by other ... chemical changes in the tissues. As the hydrogen atoms return to their usual ...

  3. Sandstorm in the chest?

    Directory of Open Access Journals (Sweden)

    Talluri MR

    2011-07-01

    Full Text Available A 32 year old female presented with dry cough and progressive breathlessness of one year duration. There was no history suggestive of collagen vascular disease, lung parenchymal infection or allergic airway disease. Clinical evaluation showed basal fine inspiratory crepitations. Radiographic examination of the chest revealed a black pleura line and lung parenchymal calcification. CT scan of the chest demonstrated nodular calcification of lung parenchyma with a “crazy pavement” pattern, which is suggestive of alveolar calcification. Pulmonary function test showed a severe restrictive defect. On transbronchial lung biopsy calcific spherules suggestive of the alveolar microlithiasis were seen. Diagnosis of pulmonary alveolar microlithiasis was made and symptomatic treatment was given, as there is no specific therapy available. The case illustrates an unusual cause of shortness of breath in a young female with striking radiographic features.

  4. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Vejle-Sørensen, Jens Kristian; Thomsen, Henrik;

    2015-01-01

    of clinical supervisors. Optimal collimation is determined by European and Regional Danish guidelines. The areal between current and optimal collimation is calculated. The experimental research is performed in September - October 2014 Siemens Axiom Aristos digital radiography system DR using 150 kV, 1,25 -3......Purpose: Quality improvement of basic radiography focusing on collimation and dose reduction in digital chest radiography Methods and Materials:A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from...... one hundred fifty self-reliant female patients between 15 and 55 years of age are included in the study. The clinical research is performed between September and November 2014 where 3rd year Radiography students collect data on four Danish x-ray departments using identical procedures under guidance...

  5. CHEST PHYSIOTHERAPY FOR INFANTS

    OpenAIRE

    2014-01-01

    In the normal lung, secretions are removed by Mucociliary activity, normal breathing cycles, and cough. In disease, increased secretion viscosity and volume, dyskinesia of the cilia, and ineffective cough combine to reduce the ability to clear secretions, and may increase exacerbations and infections. Many chest physiotherapy techniques like postural drainage, percussion and vibration are used since many years. These techniques are derived from adult studies but these techniques are quite str...

  6. An Atypical Cause of Atypical Chest Pain

    OpenAIRE

    2014-01-01

    The present report describes a case involving a 57-year-old HIV-positive man who presented with acute retrosternal chest pain accompanied by 24 h of fever. Septic arthritis of the manubriosternal joint was diagnosed based on magnetic resonance imaging findings in addition to Staphylococcus aureus bacteremia. To the authors’ knowledge, the present case is only the 12th reported case of manubriosternal septic arthritis, and the first in an HIV-positive patient. Early diagnosis and treatment can...

  7. High field superconductor development and understanding

    Energy Technology Data Exchange (ETDEWEB)

    Larbalestier, David C. [Florida State Univ., Tallahassee, FL (United States); Lee, Peter J. [Florida State Univ., Tallahassee, FL (United States); Tarantini, Chiara [Florida State Univ., Tallahassee, FL (United States)

    2014-09-28

    All present circular accelerators use superconducting magnets to bend and to focus the particle beams. The most powerful of these machines is the large hadron collider (LHC) at CERN. The main ring dipole magnets of the LHC are made from Nb-Ti but, as the machine is upgraded to higher luminosity, more powerful magnets made of Nb3Sn will be required. Our work addresses how to make the Nb3Sn conductors more effective and more suitable for use in the LHC. The most important property of the superconducting conductor used for an accelerator magnet is that it must have very high critical current density, the property that allows the generation of high magnetic fields in small spaces. Nb3Sn is the original high field superconductor, the material which was discovered in 1960 to allow a high current density in the field of about 9 T. For the high luminosity upgrade of the LHC, much higher current densities in fields of about 12 Tesla will be required. The critical value of the current density is of order 2600 A/mm2 in a field of 12 Tesla. But there are very important secondary factors that complicate the attainment of this critical current density. The first is that the effective filament diameter must be no larger than about 40 µm. The second factor is that 50% of the cross-section of the Nb3Sn conductor that is pure copper must be protected from any poisoning by any Sn leakage through the diffusion barrier that protects the package of niobium and tin from which the Nb3Sn is formed by a high temperature reaction. These three, somewhat conflicting requirements, mean that optimization of the conductor is complex. The work described in this contract report addresses these conflicting requirements. They show that very sophisticated characterizations can uncover the way to satisfy all 3 requirements and they also suggest that the ultimate optimization of Nb3Sn is still not yet in sight

  8. Mesenchymal hamartoma of the chest wall: prenatal sonographic manifestations.

    Science.gov (United States)

    Wie, Jeong ha; Kim, Ju Yeon; Kwon, Ji Young; Ko, Hyun Sun; Shin, Jong Chul; Park, In Yang

    2013-06-01

    Mesenchymal hamartoma of the chest wall is a rare, benign lesion that arises from one or more ribs, almost exclusively found in infants. Some cases that developed in the fetal period have been reported, but accurate diagnosis was usually possible only after birth, except in a few cases in which fetal magnetic resonance imaging or computed tomography were performed. We present a case of a congenital mesenchymal hamartoma of the chest wall. Although the diagnosis was not confirmed until birth, the prenatal sonographic examination showed strongly suggestive findings. We review the published reports on this condition, and suggest the prenatal sonographic features. Prenatal sonography is valuable in the differential diagnosis of chest mass.

  9. High-field magnetization studies of spin-dimer behaviors on low-dimensional spin systems, LiCu2-xZnxO2 and FeTe3O7X (X = Cl, Br)

    Science.gov (United States)

    Her, J. L.; Hsu, H. C.; Matsuda, Y. H.; Kindo, K.; Chou, C. C.; Yang, H. D.; Berger, H.; Chou, F. C.

    2013-03-01

    Following our previous paper reporting enhancement of magnetic moment in powder Mn11Si19 (~30 microns in diameter), we report here on magnetic moment for smaller particles (~5 microns in diameter) at 5 K to 300 K. Apart from the larger particles case, magnetisation curves against field exhibit distinctive features of soft magnetic materials over the whole range of temperatures. We observed a sort of superparamagnetism in non-nanoparticles.

  10. First observation of trapped high-field seeking ultracold neutron spin states

    Energy Technology Data Exchange (ETDEWEB)

    Daum, M., E-mail: manfred.daum@psi.ch [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); TUM, Physik-Department Technische Universitaet Muenchen, Excellence Cluster Universe, Munich (Germany); Department of Physics, University of Virginia, Charlottesville, VA 22904-4714 (United States); Fierlinger, P. [TUM, Physik-Department Technische Universitaet Muenchen, Excellence Cluster Universe, Munich (Germany); Franke, B. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); TUM, Physik-Department Technische Universitaet Muenchen, Excellence Cluster Universe, Munich (Germany); Geltenbort, P. [ILL, Institut Laue-Langevin, Grenoble (France); Goeltl, L. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); Gutsmiedl, E. [TUM, Physik-Department Technische Universitaet Muenchen, Excellence Cluster Universe, Munich (Germany); Karch, J. [Institut fuer Physik, Johannes-Gutenberg-Universitaet, Mainz (Germany); Kessler, G. [TUM, Physik-Department Technische Universitaet Muenchen, Excellence Cluster Universe, Munich (Germany); Kirch, K. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); IPP, Institut f. Teilchenphysik, ETH Zuerich, CH-8093 Zuerich (Switzerland); Koch, H.-C.; Kraft, A.; Lauer, T. [Institut fuer Physik, Johannes-Gutenberg-Universitaet, Mainz (Germany); Lauss, B. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); Pierre, E. [LPC, Laboratoire de Physique Corpusculaire, ENSICAEN-CNRS/IN2P3, Caen (France); Pignol, G. [LPSC, Laboratoire de Physique Subatomique et de Cosmologie, UJF-CNRS/IN2P3-INPG, Grenoble (France); Reggiani, D.; Schmidt-Wellenburg, P. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); Sobolev, Yu.; Zechlau, T. [Institut fuer Physik, Johannes-Gutenberg-Universitaet, Mainz (Germany); Zsigmond, G. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland)

    2011-10-25

    Ultracold neutrons were stored in a volume, using a magnetic dipole field shutter. Radial confinement was provided by material walls. Low-field seeking neutrons were axially confined above the magnetic field. High-field seeking neutrons are trapped inside the magnetic field. They can systematically shift the measured neutron lifetime to lower values in experiments with magnetic confinement.

  11. In-depth magnetic characterization of a [2 × 2] Mn(III) square grid using SQUID magnetometry, inelastic neutron scattering, and high-field electron paramagnetic resonance spectroscopy

    DEFF Research Database (Denmark)

    Konstantatos, Andreas; Bewley, Robert; Barra, Anne Laure

    2016-01-01

    A tetranuclear [2 × 2] grid-like manganese(III) Schiff base complex, Mn4, has been synthesized and characterized by single-crystal X-ray crystallography. Direct-current magnetization measurements were performed on the system and proved to be insufficient for an accurate magnetic model to be deduc...

  12. The neonatal chest

    Energy Technology Data Exchange (ETDEWEB)

    Lobo, Luisa [Servico de Imagiologia Geral do Hospital de Santa Maria, Av. Prof. Egas Moniz, 1649-035 Lisbon (Portugal)]. E-mail: mluisalobo@gmail.com

    2006-11-15

    Lung diseases represent one of the most life threatening conditions in the newborn. Important progresses in modern perinatal care has resulted in a significantly improved survival and decreased morbidity, in both term and preterm infants. Most of these improvements are directly related to the better management of neonatal lung conditions, and infants of very low gestational ages are now surviving. This article reviews the common spectrum of diseases of the neonatal lung, including medical and surgical conditions, with emphasis to the radiological contribution in the evaluation and management of these infants. Imaging evaluation of the neonatal chest, including the assessment of catheters, lines and tubes are presented.

  13. HIGH FIELD Q-SLOPE AND THE BAKING EFFECT

    Energy Technology Data Exchange (ETDEWEB)

    Ciovati, Gianluigi [JLAB

    2009-11-01

    The performance of SRF cavities made of bulk Nb at high fields (peak surface magnetic field greater than about 90 mT) is characterized by exponentially increasing RF losses (high-field Q-slope), in the absence of field emission, which are often mitigated by a low temperature (100-140 °C, 12-48h) baking. In this contribution, recent experimental results and phenomenological models to explain this effect will be briefly reviewed. New experimental results on the high-field Q-slope will be presented for cavities that had been heat treated at high temperature in the presence of a small partial pressure of nitrogen. Improvement of the cavity performances have been obtained, while surface analysis measurements on Nb samples treated with the cavities revealed significantly lower hydrogen concentration than for samples that followed standard cavity treatments.

  14. MRI of the Chest

    Medline Plus

    Full Text Available ... provides movie-like sequential imaging of the cardiovascular system that is important to assess the health and ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  15. MRI of the Chest

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the structures within ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  16. Spontaneous Radiation Emission from Short, High Field Strength Insertion Devices

    Energy Technology Data Exchange (ETDEWEB)

    Geoffrey Krafft

    2005-09-15

    Since the earliest papers on undulaters were published, it has been known how to calculate the spontaneous emission spectrum from ''short'' undulaters when the magnetic field strength parameter is small compared to unity, or in ''single'' frequency sinusoidal undulaters where the magnetic field strength parameter is comparable to or larger than unity, but where the magnetic field amplitude is constant throughout the undulater. Fewer general results have been obtained in the case where the insertion device is both short, i.e., the magnetic field strength parameter changes appreciably throughout the insertion device, and the magnetic field strength is high enough that ponderomotive effects, radiation retardation, and harmonic generation are important physical phenomena. In this paper a general method is presented for calculating the radiation spectrum for short, high-field insertion devices. It is used to calculate the emission from some insertion device designs of recent interest.

  17. Orthodontic brackets in high field MR imaging: experimental evaluation of magnetic field interactions at 3.0 tesla; Kieferorthopaedische Brackets in der Hochfeld-Magnetresonanz-Tomographie: Experimentelle Beurteilung magnetischer Anziehungs- und Rotationskraefte bei 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Kemper, J.; Adam, G. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Eppendorf, Hamburg (Germany); Klocke, A.; Kahl-Nieke, B. [Poliklinik fuer Kieferorthopaedie, Universitaetsklinikum Eppendorf, Hamburg (Germany)

    2005-12-15

    Purpose: To evaluate static magnetic field interactions for 32 commonly used orthodontic brackets in a 3.0 T magnetic resonance imaging (MRI) system. Materials and methods: 32 orthodontic brackets consisting of a steel alloy (n=27), a cobalt-chromium alloy (n=2), ceramic (n=1), ceramic with a steel slot (n=1), and titanium (n=1) from 13 different manufacturers were tested for magnetic field interactions in a static magnetic field at 3.0 T (Gyroscan Intera 3.0 T, Philips Medical Systems, Best, Netherlands). The magnetic deflection force F{sub Z} [mN] was evaluated by determining the deflection angle {beta}[ ] using the established deflection angle test according to the ASTM guidelines. The magnetic-field-induced rotational force F{sub rot} or torque was qualitatively determined using a 5-point grading scale (0: no torque; +4: very strong torque). Results: In 18 of the 32 brackets, the deflection angle {beta} was found to be > 45 and the translational force exceeded the gravitational force F{sub G} on the particular bracket (F{sub Z}: 1.2-45.7 mN). The translational force F{sub Z} was found to be up to 68.5 times greater than the gravitational force F{sub G} (F{sub Z}/F{sub G}: 1.4-68.5). The rotational force F{sub rot} was correspondingly high (+3/+4) for those brackets. For the remaining 14 objects, the deflection angles were < 45 and the torque measurements ranged from 0 to +2. The static magnetic field did not affect the titanium bracket and the ceramic bracket. No measurable translational and rotational forces were found. (orig.)

  18. Operation of a 400MHz NMR magnet using a (RE:Rare Earth)Ba2Cu3O7-x high-temperature superconducting coil: Towards an ultra-compact super-high field NMR spectrometer operated beyond 1GHz.

    Science.gov (United States)

    Yanagisawa, Y; Piao, R; Iguchi, S; Nakagome, H; Takao, T; Kominato, K; Hamada, M; Matsumoto, S; Suematsu, H; Jin, X; Takahashi, M; Yamazaki, T; Maeda, H

    2014-10-18

    High-temperature superconductors (HTS) are the key technology to achieve super-high magnetic field nuclear magnetic resonance (NMR) spectrometers with an operating frequency far beyond 1GHz (23.5T). (RE)Ba2Cu3O7-x (REBCO, RE: rare earth) conductors have an advantage over Bi2Sr2Ca2Cu3O10-x (Bi-2223) and Bi2Sr2CaCu2O8-x (Bi-2212) conductors in that they have very high tensile strengths and tolerate strong electromagnetic hoop stress, thereby having the potential to act as an ultra-compact super-high field NMR magnet. As a first step, we developed the world's first NMR magnet comprising an inner REBCO coil and outer low-temperature superconducting (LTS) coils. The magnet was successfully charged without degradation and mainly operated at 400MHz (9.39T). Technical problems for the NMR magnet due to screening current in the REBCO coil were clarified and solved as follows: (i) A remarkable temporal drift of the central magnetic field was suppressed by a current sweep reversal method utilizing ∼10% of the peak current. (ii) A Z2 field error harmonic of the main coil cannot be compensated by an outer correction coil and therefore an additional ferromagnetic shim was used. (iii) Large tesseral harmonics emerged that could not be corrected by cryoshim coils. Due to those harmonics, the resolution and sensitivity of NMR spectra are ten-fold lower than those for a conventional LTS NMR magnet. As a result, a HSQC spectrum could be achieved for a protein sample, while a NOESY spectrum could not be obtained. An ultra-compact 1.2GHz NMR magnet could be realized if we effectively take advantage of REBCO conductors, although this will require further research to suppress the effect of the screening current.

  19. High-field EPR spectroscopy of thermal donors in silicon

    DEFF Research Database (Denmark)

    Dirksen, R.; Rasmussen, F.B.; Gregorkiewicz, T.

    1997-01-01

    Thermal donors generated in p-type boron-doped Czochralski-grown silicon by a 450 degrees C heat treatment have been studied by high-field magnetic resonance spectroscopy. In the experiments conducted at a microwave frequency of 140 GHz and in a magnetic field of approximately 5 T four individual...... thermal donors species could be resolved. These were observed in their singly ionized TD+ charge state. For the first time in the four decades of thermal donor research the g tensor values for specific members of the Si-NL8 family are given. Also the symmetry of the observed species is discussed....

  20. High-field spin dynamics of antiferromagnetic quantum spin chains

    DEFF Research Database (Denmark)

    Enderle, M.; Regnault, L.P.; Broholm, C.;

    2000-01-01

    The characteristic internal order of macroscopic quantum ground states in one-dimensional spin systems is usually not directly accessible, but reflected in the spin dynamics and the field dependence of the magnetic excitations. In high magnetic fields quantum phase transitions are expected. We...... present recent work on the high-field spin dynamics of the S = I antiferromagnetic Heisenberg chains NENP (Haldane ground state) and CsNiCl3 (quasi-1D HAF close to the quantum critical point), the uniform S = 1/2 chain CTS, and the spin-Peierls system CuGeO3. (C) 2000 Elsevier Science B,V. All rights...

  1. Design Analysis on High-field Microstrip Circulator Temperature Compensating Magnetic Circuit%高场带线环行器温度补偿磁路的设计分析

    Institute of Scientific and Technical Information of China (English)

    高昌杰; 李晓华

    2014-01-01

    According to the magnetic circuit model of the circulator,the calculation formula of temperature compen-sation of magnetic circuit is derived. Combining the simulation software ANSOFT HFSS, a more accurate analysis method of temperature compensation of magnetic circuit and the optimizing design measures are introduced. The calculated results of using the design analysis method agree with the results of test, this method will guide design and implementation of the optimal temperature compensation of magnetic circuit.%本文根据环行器实际磁路模型,对温度补偿磁路的计算公式进行了推导,并结合Ansoft HF-SS仿真软件,提出了一种温度补偿磁路的较准确计算分析方法和最佳化设计措施。该设计分析方法得到的计算结果与试验比较一致,对设计和实现最佳温度补偿磁路具有较强的指导作用。

  2. Optimizing brain tumor resection. High-field interventional MR imaging.

    Science.gov (United States)

    Tummala, R P; Chu, R M; Liu, H; Truwit, C L; Hall, W A

    2001-11-01

    High-field strength iMRI guidance is an effective tool for brain tumor resection. Although its use lengthens the average time for a craniotomy, the reward is a more extensive tumor excision compared with conventional neurosurgery without an increased risk to the patient (Table 4). Although intraoperative patient transfer into and out of the magnet is cumbersome, the possibility for complete resection, especially for a low-grade glioma, makes the effort worthwhile. The cost and technical support required for this system presently limits its use to only a few sites worldwide. As with any technology, further refinements will make this system less expensive and more attainable. Practical consideration aside, high-field strength iMRI is presently [table: see text] the most effective tool available for brain tumor resection. Because of its novelty, future studies are necessary to determine if this technology lowers the incidence of and extends the duration to tumor recurrence as the preliminary data in children suggests. These are the ultimate measures of efficacy for any brain tumor treatment. Based on the rapid advancement of technology, will today's high-field strength interventional magnet become tomorrow's low-field system? Very high-field strength designs may improve diagnostic capabilities through higher resolution, but their interventional applications may be hindered by increased sensitivity for clinically insignificant abnormalities and decreased specificity for clinically relevant lesions. As new technology is developed, clinicians must continue to explore and refine the existing high-field strength iMRI to make it cost-effective and widely applicable.

  3. SU-E-J-03: Characterization of the Precision and Accuracy of a New, Preclinical, MRI-Guided Focused Ultrasound System for Image-Guided Interventions in Small-Bore, High-Field Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Ellens, N [Johns Hopkins University, Baltimore, Maryland (United States); Farahani, K [National Cancer Institute, Bethesda, MD (United States)

    2015-06-15

    Purpose: MRI-guided focused ultrasound (MRgFUS) has many potential and realized applications including controlled heating and localized drug delivery. The development of many of these applications requires extensive preclinical work, much of it in small animal models. The goal of this study is to characterize the spatial targeting accuracy and reproducibility of a preclinical high field MRgFUS system for thermal ablation and drug delivery applications. Methods: The RK300 (FUS Instruments, Toronto, Canada) is a motorized, 2-axis FUS positioning system suitable for small bore (72 mm), high-field MRI systems. The accuracy of the system was assessed in three ways. First, the precision of the system was assessed by sonicating regular grids of 5 mm squares on polystyrene plates and comparing the resulting focal dimples to the intended pattern, thereby assessing the reproducibility and precision of the motion control alone. Second, the targeting accuracy was assessed by imaging a polystyrene plate with randomly drilled holes and replicating the hole pattern by sonicating the observed hole locations on intact polystyrene plates and comparing the results. Third, the practicallyrealizable accuracy and precision were assessed by comparing the locations of transcranial, FUS-induced blood-brain-barrier disruption (BBBD) (observed through Gadolinium enhancement) to the intended targets in a retrospective analysis of animals sonicated for other experiments. Results: The evenly-spaced grids indicated that the precision was 0.11 +/− 0.05 mm. When image-guidance was included by targeting random locations, the accuracy was 0.5 +/− 0.2 mm. The effective accuracy in the four rodent brains assessed was 0.8 +/− 0.6 mm. In all cases, the error appeared normally distributed (p<0.05) in both orthogonal axes, though the left/right error was systematically greater than the superior/inferior error. Conclusions: The targeting accuracy of this device is sub-millimeter, suitable for many

  4. High field MR imaging: magnetic field interactions of aneurysm clips, coronary artery stents and iliac artery stents with a 3.0 Tesla MR system; Hochfeld-Magnetresonanztomographie: Magnetische Anziehungs- und Rotationskraefte auf metallische Implantate bei 3,0 T

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, T.; Schmiedel, A.; Hackenbroch, M.; Hofer, U.; Urbach, H.; Traeber, F.; Schild, H. [Radiologische Univ. Bonn (Germany); Maintz, D. [Radiologische Univ. Muenster (Germany); Pavlidis, C. [Klinik fuer Neurochirurgie, Univ. Bonn (Germany); Hoeher, M. [Medizinische Univ. II Ulm (Germany)

    2004-05-01

    Purpose: to evaluate magnetic field interactions of commonly used biomedical implants at 3.0 tesla. Materials and methods: fourteen aneurysm clips designed for permanent placement in intracranial aneurysms, 19 coronary artery stents and 20 iliac artery stents were evaluated in an actively shielded compact 3.0 T MR system (Intera, Philips Medical Systems, Best, the Netherlands, length of magnet 1.57 m). The magnetic deflection forces (translational movement) were evaluated as follows: the implants were suspended by a fine string and placed in the magnet bore at the location of the maximum magnetic field gradient. The translational forces F{sub z} were calculated from the measured angle of deflection from the vertical axis. The magnetic field-induced torque (rotational forces) was evaluated as follows: each implant was placed in the center of the magnetic bore parallel to the static magnetic field B0 (position 0 ). Any possible displacement of the implant was noted on a millimeter scale and any torque qualitatively evaluated using a 5 point grading scale (0: no torque; + 4: very strong torque). The implant was turned in steps of 45 , and the procedure was repeated to encompass a full 360 rotation. Results: in 52 of the 53 devices tested, the deflection force (deflection angle: range 0-21 , translational force: range 0-3.8 mN) was less than the gravitational force (i.e., the implant's weight). These devices (n = 52/53) did not show any alignment to or rotation in the magnetic field at any of the various 45 -increment positions corresponding to a qualitative torque evaluation of grade 0/4. One device (n = 1/53), an iliac artery stent made of stainless steel (Zenith, Cook, Moenchengladbach, BRD), was found to have deflection forces (deflection angle 88 translational force 299 mN) greatly exceeding the gravitational force as well as a pronounced torque (grade 4/4). (orig.) [German] Ziel: Die In-vitro-Evaluierung verschiedener biomedizinischer Implantate hinsichtlich

  5. Ressonância magnética do tórax: aplicações tradicionais e novas, com ênfase em pneumologia Magnetic resonance imaging of the chest: current and new applications, with an emphasis on pulmonology

    Directory of Open Access Journals (Sweden)

    Marcel Koenigkam Santos

    2011-04-01

    Full Text Available O objetivo deste estudo de revisão foi apresentar as principais aplicações da ressonância magnética (RM no estudo do tórax, incluindo a descrição de novas técnicas. Na ultima década, esse método teve grande evolução, com novos equipamentos, incluindo a interconexão simultânea de bobinas e a movimentação da mesa simultaneamente à aquisição das imagens, além do advento de novas técnicas rápidas de aquisição de imagem, tais como imagem paralela e aquisição parcial de dados, com ou sem utilização de apneia, somando-se ainda a introdução de novos agentes de contraste. Todos esses avanços fizeram com que a RM tenha ganhado espaço no estudo de diferentes patologias do tórax, incluindo as doenças pulmonares. Atualmente, a RM pode ser considerada a modalidade de escolha para a avaliação das lesões mediastinais, da parede torácica e dos tumores do sulco superior, mas também pode auxiliar no diagnóstico de doenças pulmonares, pleurais, cardíacas e da vasculatura pulmonar. A angiografia pulmonar por RM pode ser utilizada na avaliação de várias doenças vasculares pulmonares, e seu papel no estudo do tromboembolismo vem crescendo. A RM cardíaca, devido à possibilidade de avaliação morfológica e funcional em um mesmo exame, também já faz parte da rotina clínica na investigação de muitas patologias cardíacas. Por fim, o papel da RM vem sendo ampliado para a identificação e caracterização de nódulos pulmonares, avaliação das doenças das vias aéreas e caracterização dos derrames pleurais.The objective of the present review study was to present the principal applications of magnetic resonance imaging (MRI of the chest, including the description of new techniques. Over the past decade, this method has evolved considerably because of the development of new equipment, including the simultaneous interconnection of phased-array multiple radiofrequency receiver coils and remote control of the table

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... magnetic field is produced by passing an electric current through wire coils in most MRI units. Other ... that are detected by the coils. The electric current does not come in contact with the patient. ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... intercom. Many MRI centers allow a friend or parent to stay in the room as long as they are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  8. MRI of the Chest

    Medline Plus

    Full Text Available ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ... tell the technologist if you have medical or electronic devices in your body. These objects may interfere ...

  9. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... that magnetic resonance imaging harms the fetus, pregnant women usually are advised not to have an MRI ...

  10. MRI of the Chest

    Science.gov (United States)

    ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... that magnetic resonance imaging harms the fetus, pregnant women usually are advised not to have an MRI ...

  11. Radiology illustrated. Chest radiology

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Soo [Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of). Dept. of Radiology; Han, Joungho [Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of). Dept. of Pathology; Chung, Man Pyo [Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of). Dept. of Medicine; Jeong, Yeon Joo [Pusan National Univ. Hospital, Busan (Korea, Republic of). Dept. of Radiology

    2014-04-01

    Pattern approach to the diagnosis of lung diseases based on CT scan appearances. Guide to quick and reliable differential diagnosis. CT-pathology correlation. Emphasis on state-of-the-art MDCT. The purpose of this atlas is to illustrate how to achieve reliable diagnoses when confronted by the different abnormalities, or ''disease patterns'', that may be visualized on CT scans of the chest. The task of pattern recognition has been greatly facilitated by the advent of multidetector CT (MDCT), and the focus of the book is very much on the role of state-of-the-art MDCT. A wide range of disease patterns and distributions are covered, with emphasis on the typical imaging characteristics of the various focal and diffuse lung diseases. In addition, clinical information relevant to differential diagnosis is provided and the underlying gross and microscopic pathology is depicted, permitting CT-pathology correlation. The entire information relevant to each disease pattern is also tabulated for ease of reference. This book will be an invaluable handy tool that will enable the reader to quickly and easily reach a diagnosis appropriate to the pattern of lung abnormality identified on CT scans.

  12. Chest radiographic findings of leptospirosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mee Hyun; Jung, Hee Tae; Lee, Young Joong; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1986-04-15

    1. A study on chest radiographic findings of 54 cases with pneumonia like symptoms was performed. Of 54 cases, 8 cases were confirmed to be leptospirosis and 7 cases were leptospirosis combined with Korean hemorrhagic fever. 2. Of 8 cases of leptospirosis, 4 cases showed abnormal chest radiographic findings: acinar nodular type 2, massive confluent consolidation type 2. Of 7 cases of leptospirosis combined with Korean hemorrhagic fever: acinar nodular type 3, massive confluent consolidation type 1, and increased interstitial markings type 1 respectively. 3. It was considered to be difficult to diagnose the leptospirosis on chest radiographic findings alone, especially the case combined with Korean hemorrhagic fever.

  13. Interpretation of neonatal chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hye Kyung [Dept. of Radiology, Kangwon National University Hospital, Chuncheon (Korea, Republic of)

    2016-05-15

    Plain radiographs for infants in the neonatal intensive care unit are obtained using the portable X-ray equipment in order to evaluate the neonatal lungs and also to check the position of the tubes and catheters used for monitoring critically-ill neonates. Neonatal respiratory distress is caused by a variety of medical or surgical disease conditions. Clinical information about the gestational week, respiratory symptoms, and any events during delivery is essential for interpretation of the neonatal chest radiographs. Awareness of common chest abnormality in the prematurely born or term babies is also very important for chest evaluation in the newborn. Furthermore, knowledge about complications such as air leaks and bronchopulmonary dysplasia following treatment are required to accurately inform the clinicians. The purpose of this article was to briefly review radiographic findings of chest diseases in newborns that are relatively common in daily practice.

  14. High field superconductor development and understanding project, Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Larbalestier, David C.; Lee, Peter J.

    2009-07-15

    Over 25 years the Applied Superconductivity Center at the University of Wisconsin-Madison provided a vital technical resource to the High Energy Physics community covering development in superconducting strand for HEP accelerator magnet development. In particular the work of the group has been to develop the next generation of high field superconductors for high field application. Grad students Mike Naus, Chad Fischer, Arno Godeke and Matt Jewell improved our understanding of the microstructure and microchemistry of Nb3Sn and their impact on the physical and mechanical properties. The success of this work has led to the continued funding of this work at the ASC after it moved to the NHMFL and also to direct funding from BNL for some aspects of Nb3Sn cable evaluation.

  15. CHEST WALL HAMARTOMA : Case Report

    OpenAIRE

    Gülden DİNİZ; Ortaç, Ragıp; Aktaş, Safiye; TEMİR, Günyüz; HOŞGÖR, Münevver; Karaca, İrfan

    2005-01-01

    A case of four-month – old girl diagnosed as chest wall hamartoma is presented. This entity is an extremely rare but characteristic lesion of the ribs usually presenting in the neonate or infant with a mass or respiratory symptoms. Complete sponraneous regression of the lesion has been reported. Recently conservative management of asymptomatic childiren was recommended. Although rare, this condition ought to be kept in mind while dealing with infantile chest wall masses to avoid an errone...

  16. CHEST WALL HAMARTOMA : Case Report

    OpenAIRE

    Gülden DİNİZ; Ortaç, Ragıp; Aktaş, Safiye; HOŞGÖR, Günyüz TEMİR2Münevver; Karaca, İrfan

    2005-01-01

    A case of four-month – old girl diagnosed as chest wall hamartoma is presented. This entity is an extremely rare but characteristic lesion of the ribs usually presenting in the neonate or infant with a mass or respiratory symptoms. Complete sponraneous regression of the lesion has been reported. Recently conservative management of asymptomatic childiren was recommended. Although rare, this condition ought to be kept in mind while dealing with infantile chest wall masses to avoid...

  17. Role of Cross Sectional Imaging in Isolated Chest Wall Tuberculosis

    Science.gov (United States)

    Sanyal, Shantiranjan; Sharma, Barun K.; Prakash, Arjun; Dhingani, Dhabal D.; Bora, Karobi

    2017-01-01

    Introduction Isolated chest wall tuberculosis though a rare entity, the incidence of it has been on rise among immunocompromised population making it an important challenging diagnosis for the physicians. Its clinical presentation may resemble pyogenic chest wall abscess or chest wall soft tissue tumour. Sometimes it is difficult to detect clinically or on plain radiograph. Aim The present study was conducted with an aim to evaluate the common sites and varying appearances of isolated chest wall tuberculosis. Materials and Methods A hospital based cross-sectional retrospective study was conducted in Assam Medical College and Hospital, a tertiary care centre in North East India. The study group comprise of 21 patients (n=15 male and n=6 females) with isolated chest wall tuberculosis without associated pulmonary or spinal involvement who were subjected to Computed Tomography/Magnetic Resonance Imaging (CT/MRI) of the thorax following initial Ultrasonogram (USG) evaluation of the local site. Pathological correlation was done from imaging guided sampling of the aspirate or surgery. Results Variable sites of involvement were seen in the chest wall in our patients (n=21), with chest wall abscess formation being the most common presentation and rib being the most common bony site affected in the thoracic cage. Bony sclerosis was noted in 11 patients (52.4%), periosteal reaction in 10 patients (47.6%) and sequestration in five patients (23.8%). CT/MRI not only localized the exact site and extent of the abscesses which facilitated guided aspirations, but also helped in detecting typical bony lesions thereby, differentiating from pyogenic osteomyelitis besides ruling out associated pulmonary or pleural involvement in such patients. Conclusion Cross-sectional imaging plays an important role by giving a wholesome picture of both soft tissue and bony pathology. It is important to have adequate understanding of the radiologic manifestations of the chest wall involvement and

  18. MRI of the Chest

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose and treat medical ...

  19. Metal-Metal Interactions in Trinuclear Copper(II) Complexes [Cu3(RCOO)4(H2TEA)2] and Binuclear [Cu2(RCOO)2(H2TEA)2]. Syntheses and Combined Structural, Magnetic, High-Field Electron Paramagnetic Resonance, and Theoretical Studies.

    Science.gov (United States)

    Ozarowski, Andrew; Calzado, Carmen J; Sharma, Raj Pal; Kumar, Santosh; Jezierska, Julia; Angeli, Celestino; Spizzo, Federico; Ferretti, Valeria

    2015-12-21

    The trinuclear [Cu3(RCOO)4(H2TEA)2] copper(II) complexes, where RCOO(-) = 2-furoate (1), 2-methoxybenzoate (2), and 3-methoxybenzoate (3, 4), as well as dimeric species [Cu2(H2TEA)2(RCOO)2]·2H2O, have been prepared by adding triethanolamine (H3TEA) at ambient conditions to hydrated Cu(RCOO)2 salts. The newly synthesized complexes have been characterized by elemental analyses, spectroscopic techniques (IR and UV-visible), magnetic susceptibility, single crystal X-ray structure determination and theoretical calculations, using a Difference Dedicated Configuration Interaction approach for the evaluation of magnetic coupling constants. In 1 and 2, the central copper atom lies on an inversion center, while in the polymorphs 3 and 4, the three metal centers are crystallographically independent. The zero-field splitting parameters of the trimeric compounds, D and E, were derived from high-field, high-frequency electron paramagnetic resonance spectra at temperatures ranging from 3 to 290 K and were used for the interpretation of the magnetic data. It was found that the dominant interaction between the terminal and central Cu sites J12 is ferromagnetic in nature in all complexes, even though differences have been found between the symmetrical or quasi-symmetrical complexes 1-3 and non-symmetrical complex 4, while the interaction between the terminal centers, J23, is negligible.

  20. Discrimination of soybean oil adulterated frying oil by high-field nuclear magnetic resonance%煎炸老油掺伪大豆油的高场核磁检测

    Institute of Scientific and Technical Information of China (English)

    李玉邯; 陈宇飞; 杨柳; 王维坚

    2016-01-01

    通过高场核磁共振仪检测了纯大豆油和掺伪了煎炸老油的大豆油并对谱图进行积分。通过谱图对比发现了三个鉴别指标,第一个鉴别指标是在δ=1.58处,纯大豆油有明显特征峰,而煎炸老油在该处无特征峰;第二个鉴别指标是在δ=2.77~2.84处,纯大豆油特征峰的积分面积高于掺伪了煎炸老油的大豆油(添加50%煎炸老油积分面积为1.51,纯大豆油积分面积为2.04),并且随着煎炸老油添加量的增加积分面积逐渐减小;第三个鉴别指标是在δ=5.25~5.42处,纯大豆油特征峰的积分面积明显高于掺伪了煎炸老油的大豆油(添加50%煎炸老油积分面积为3.98,纯大豆油积分面积为4.87),而且也随着煎炸老油添加量的增加积分面积逐渐减小。%The pure soybean oil and frying soybean oil were detected by high–field nuclear magnetic resonance instrument and the spectrograms were integrated. There were three identification methods. The first one was characteristic peak atδ=1.58 which could be detected obviously in the pure oil and couldn’t be detected in frying soybean oil. The second was atδ=2.77~2.84,where the integral area of pure soybean was higher than the frying oil (the integral area of add 50%frying oil was 1.51,and the integral area of pure soybean oil was 2.04). The third was atδ=5.25~5.42,where the integral area of pure soybean was also significantly higher than the frying oil(the integral area of add 50%frying oil was 3.98,the integral area of pure soybean oil was 4.87). And with the addition of frying oil,the integral area decreased.

  1. Contemporary management of flail chest.

    Science.gov (United States)

    Vana, P Geoff; Neubauer, Daniel C; Luchette, Fred A

    2014-06-01

    Thoracic injury is currently the second leading cause of trauma-related death and rib fractures are the most common of these injuries. Flail chest, as defined by fracture of three or more ribs in two or more places, continues to be a clinically challenging problem. The underlying pulmonary contusion with subsequent inflammatory reaction and right-to-left shunting leading to hypoxia continues to result in high mortality for these patients. Surgical stabilization of the fractured ribs remains controversial. We review the history of management for flail chest alone and when combined with pulmonary contusion. Finally, we propose an algorithm for nonoperative and surgical management.

  2. Accuracy of chest radiography versus chest computed tomography in hemodynamically stable patients with blunt chest trauma

    Institute of Scientific and Technical Information of China (English)

    Mojtaba Chardoli; Toktam Hasan-Ghaliaee; Hesam Akbari; Vafa Rahimi-Movaghar

    2013-01-01

    Objective:Thoracic injuries are responsible for 25% of deaths of blunt traumas.Chest X-ray (CXR) is the first diagnostic method in patients with blunt trauma.The aim of this study was to detect the accuracy of CXR versus chest computed tomograpgy (CT) in hemodynamically stable patients with blunt chest trauma.Methods:Study was conducted at the emergency department of S ina Hospital from March 2011 to March 2012.Hemodynamically stable patients with at least 16 years of age who had blunt chest trauma were included.All patients underwent the same diagnostic protocol which consisted of physical examination,CXR and CT scan respectively.Results:Two hundreds patients (84% male and 16% female) were included with a mean age of(37.9±13.7) years.Rib fracture was the most common finding of CXR (12.5%) and CT scan (25.5%).The sensitivity of CXR for hemothorax,thoracolumbar vertebra fractures and rib fractures were 20%,49% and 49%,respectively.Pneumothorax,foreign body,emphysema,pulmonary contusion,liver hematoma and sternum fracture were not diagnosed with CXR alone.Conclusion:Applying CT scan as the first-line diagnostic modality in hemodynamically stable patients with blunt chest trauma can detect pathologies which may change management and outcome.

  3. Accuracy of chest radiography versus chest computed tomography in hemodynamically stable patients with blunt chest trauma

    Directory of Open Access Journals (Sweden)

    Chardoli Mojtaba

    2013-12-01

    Full Text Available 【Abstract】 Objective: Thoracic injuries are respon- sible for 25% of deaths of blunt traumas. Chest X-ray (CXR is the first diagnostic method in patients with blunt trauma. The aim of this study was to detect the accuracy of CXR versus chest computed tomograpgy (CT in hemodynami- cally stable patients with blunt chest trauma. Methods: Study was conducted at the emergency department of Sina Hospital from March 2011 to March 2012. Hemodynamically stable patients with at least 16 years of age who had blunt chest trauma were included. All patients underwent the same diagnostic protocol which consisted of physical examination, CXR and CT scan respectively. Results: Two hundreds patients (84% male and 16% female were included with a mean age of (37.9±13.7 years. Chin J Traumatol 2013;16(6:351-354 Rib fracture was the most common finding of CXR (12.5% and CT scan (25.5%. The sensitivity of CXR for hemothorax, thoracolumbar vertebra fractures and rib fractures were 20%, 49% and 49%, respectively. Pneumothorax, foreign body, emphysema, pulmonary contusion, liver hematoma and ster- num fracture were not diagnosed with CXR alone. Conclusion: Applying CT scan as the first-line diag- nostic modality in hemodynamically stable patients with blunt chest trauma can detect pathologies which may change management and outcome. Key words: Radiography; Thoracic injuries; Tomography, X-ray computed

  4. Background field coils for the High Field Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Zbasnik, J.P.; Cornish, D.N.; Scanlan, R.M.; Jewell, A.M.; Leber, R.L.; Rosdahl, A.R.; Chaplin, M.R.

    1980-09-22

    The High Field Test Facility (HFTF), presently under construction at LLNL, is a set of superconducting coils that will be used to test 1-m-o.d. coils of prototype conductors for fusion magnets in fields up to 12 T. The facility consists of two concentric sets of coils; the outer set is a stack of Nb-Ti solenoids, and the inner set is a pair of solenoids made of cryogenically-stabilized, multifilamentary Nb/sub 3/Sn superconductor, developed for use in mirror-fusion magnets. The HFTF system is designed to be parted along the midplane to allow high-field conductors, under development for Tokamak fusion machines, to be inserted and tested. The background field coils were wound pancake-fashion, with cold-welded joints at both the inner and outer diameters. Turn-to-turn insulation was fabricated at LLNL from epoxy-fiberglass strip. The coils were assembled and tested in our 2-m-diam cryostat to verify their operation.

  5. High-field dipoles for future accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Wipf, S.L.

    1984-09-01

    This report presents the concept for building superconducting accelerator dipoles with record high fields. Economic considerations favor the highest possible current density in the windings. Further discussion indicates that there is an optimal range of pinning strength for a superconducting material and that it is not likely for multifilamentary conductors to ever equal the potential performance of tape conductors. A dipole design with a tape-wound, inner high-field winding is suggested. Methods are detailed to avoid degradation caused by flux jumps and to overcome problems with the dipole ends. Concerns for force support structure and field precision are also addressed. An R and D program leading to a prototype 11-T dipole is outlined. Past and future importance of superconductivity to high-energy physics is evident from a short historical survey. Successful dipoles in the 10- to 20-T range will allow interesting options for upgrading present largest accelerators.

  6. T1 and susceptibility contrast at high fields

    Science.gov (United States)

    Neelavalli, Jaladhar

    Clinical imaging at high magnetic field strengths (≥ 3Tesla) is sought after primarily due to the increased signal strength available at these fields. This increased SNR can be used to perform: (a) high resolution imaging in the same time as at lower field strengths; (b) the same resolution imaging with much faster acquisition; and (c) functional MR imaging (fMRI), dynamic perfusion and diffusion imaging with increased sensitivity. However they are also associated with increased power deposition (SAR) due to increase in imaging frequency and longer T1 relaxation times. Longer T1s mean longer imaging times for generating good T1 contrast images. On the other hand for faster imaging, at high fields fast spin echo or magnetization prepared sequences are conventionally proposed which are, however, associated with high SAR values. Imaging with low SAR is more and more important as we move towards high fields and particularly for patients with metallic implants like pacemakers or deep brain stimulator. The SAR limit acceptable for these patients is much less than the limit acceptable for normal subjects. A new method is proposed for imaging at high fields with good contrast with simultaneous reduction in power deposition. Further, T1 based contrast optimization problem in FLASH imaging is considered for tissues with different T1s but same spin densities. The solution providing optimal imaging parameters is simplified for quick and easy computation in a clinical setting. The efficacy of the simplification is evaluated and practical limits under which the simplification can be applied are worked out. The phase difference due to variation in magnetic susceptibility property among biological tissues is another unique source of contrast which is different from the conventional T1, T2 and T2* contrast. This susceptibility based phase contrast has become more and more important at high fields, partly due to contrast generation issues due to longer T 1s and shorter T2s and

  7. High-resolution magnetic resonance imaging (HR-MRI) of the pleura and chest wall: Normal findings and pathological changes; Hochaufloesende Magnetresonanztomographie (HR-MRT) von Pleura und Thoraxwand: Normalbefund und pathologische Veraenderungen

    Energy Technology Data Exchange (ETDEWEB)

    Bittner, R.C. [Strahlen- und Poliklinik, Universtaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Schnoy, N. [Pathologie, UKRV, FU Berlin (Germany); Schoenfeld, N. [Pneumologie 2, Lungenklinik Heckeshorn, Berlin (Germany); Grassot, A. [Radiologie, Lungenklinik Heckeshorn, Berlin (Germany); Loddenkemper, R. [Pneumologie 2, Lungenklinik Heckeshorn, Berlin (Germany); Lode, H. [Pneumologie 1, Lungenklinik Heckeshorn, Berlin (Germany); Kaiser, D. [Thoraxchirurgie, Lungenklinik Heckeshorn, Berlin (Germany); Krumhaar, D. [Abt. fuer Lungenkranke, Lungenklinik Havelhoehe, Berlin (Germany); Felix, R. [Strahlen- und Poliklinik, Universtaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany)

    1995-04-01

    To determine the value of high-resolution MRI in pleural and chest wall diseases, the normal and pathologic costal pleura and adjacent chest wall between paravertebral and the axillar region were examined with contrast enhanced high-resolution T{sub 1}-weighted MRI images using a surface coil. Normal anatomy was evaluated in 5 healthy volunteers and a normal specimen of the thoracic wall, and correlation was made with corresponding HR-CT and histologic sections. CT-proved focal and diffuse changes of the pleura and the chest wall in 36 patients underwent HR-MRI, and visual comparison of MRI and CT was done retrospectively. Especially sagittal T{sub 1}-weighted HR-MRI images allowed accurate delineation of the peripleural fat layer (PFL) and the innermost intercostal muscle (IIM), which served as landmarks of the intact inner chest wall. PFL and IIM were well delineated in 3/4 patients with tuberculous pleuritis, and in all 7 patients with non-specific pleuritis, as opposed to impairment of the PFL and/or the IIM, which was detected in 15/18 malignancies as a pattern of malignant chest wall involvement. In one case of tuberculous pleural empyema with edema of the inner chest wall HR-MRI produced false positive diagnosis of malignant disease. HR-MRI images improved non-invasive evaluation of pleural and chest wall diseases, and allowed for differentiation of bengin and malignant changes. (orig./MG) [Deutsch] Um den Stellenwert der hochaufloesenden MRT bei Pleura- und Thoraxwanderkrankungen zu bestimmen, wurden normale und pathologisch veraenderte kostale Pleura (paravertebral bis axillaer) und angrenzende Thoraxwand mit Hilfe einer Oberflaechenspule und kontrastmittelunterstuetzen T{sub 1}-gewichteten HR-MRT-Aufnahmen untersucht. Die normale Anatomie wurde bei 5 gesunden Probanden sowie einem normalen Thoraxwandpraeparat dargestellt und mit korrespondierenden hochaufloesenden CT- sowie histologischen Aufnahmen verglichen. CT-dokumentierte fokale und diffuse Pleura

  8. An atypical cause of atypical chest pain.

    Science.gov (United States)

    Zaheen, Ahmad; Siemieniuk, Reed A; Gudgeon, Patrick

    2014-09-01

    The present report describes a case involving a 57-year-old HIV-positive man who presented with acute retrosternal chest pain accompanied by 24 h of fever. Septic arthritis of the manubriosternal joint was diagnosed based on magnetic resonance imaging findings in addition to Staphylococcus aureus bacteremia. To the authors' knowledge, the present case is only the 12th reported case of manubriosternal septic arthritis, and the first in an HIV-positive patient. Early diagnosis and treatment can circumvent the need for surgical intervention. Based on the present case report and review of the literature, the authors summarize the epidemiology, appropriate imaging and suggestions for antibiotic therapy for this rare presentation.

  9. An Atypical Cause of Atypical Chest Pain

    Directory of Open Access Journals (Sweden)

    Ahmad Zaheen

    2014-01-01

    Full Text Available The present report describes a case involving a 57-year-old HIV-positive man who presented with acute retrosternal chest pain accompanied by 24 h of fever. Septic arthritis of the manubriosternal joint was diagnosed based on magnetic resonance imaging findings in addition to Staphylococcus aureus bacteremia. To the authors’ knowledge, the present case is only the 12th reported case of manubriosternal septic arthritis, and the first in an HIV-positive patient. Early diagnosis and treatment can circumvent the need for surgical intervention. Based on the present case report and review of the literature, the authors summarize the epidemiology, appropriate imaging and suggestions for antibiotic therapy for this rare presentation.

  10. Direct imaging of rf waveguide modes via ultra-high field NMR

    CERN Document Server

    Tonyushkin, A; Van de Moortele, P -F; Adriany, G; Kiruluta, A

    2016-01-01

    We demonstrate an experimental method for direct 2D and 3D imaging of magnetic rf field distribution in metal waveguides based on traveling wave (TW) nuclear-magnetic resonance (NMR) imaging at ultra-high field (>7T). The typical apparatus would include an ultra-high field whole body or small bore NMR scanner, waveguide elements filled with NMR active dielectrics with predefined electric and magnetic properties, and TW rf transmit-receive probes. We validated the technique by obtaining TW magnetic-resonance (MR) images of the magnetic field distribution of the rf modes of circular waveguide filled with deionized water in a 16.4 T small-bore NMR scanner and compared the MR images with numerical simulations. Our NMR technique opens up a practical way of imaging of previously inaccessible rf field distribution of modes inside of various shapes metal waveguides with inserted dielectric objects, including waveguide mode converters and transformers.

  11. Actinomycosis - Left Post Chest Wall

    Directory of Open Access Journals (Sweden)

    Kafil Akhtar, M. Naim, S. Shamshad Ahmad, Nazoora Khan, Uroos Abedi, A.H. Khan*

    2008-01-01

    Full Text Available A forty year old female of weak body built presented with recurring small hard lumps in let posteriorchest wall for 3 years and discharging ulcers for 3 months duration. Clinically, the provisional diagnosiswas malignancy with secondary infection. FNAC showed features suggestive of dysplasia buthistopathology confirmed the diagnosis as actinomycosis. The present case is reported due to rare incidenceof actinomycosis at post chest wall with muscle involvement.

  12. Chest wall, lung, and pleural space trauma.

    Science.gov (United States)

    Miller, Lisa A

    2006-03-01

    Chest radiographs frequently underestimate the severity and extent of chest trauma and, in some cases, fail to detect the presence of injury. CT is more sensitive than chest radiography in the detection of pulmonary, pleural, and osseous abnormalities in the patient who has chest trauma. With the advent of multidetector CT (MDCT), high-quality multiplanar reformations are obtained easily and add to the diagnostic capabilities of MDCT. This article reviews the radiographic and CT findings of chest wall, pleural, and pulmonary injuries that are seen in the patient who has experienced blunt thoracic trauma.

  13. REVIEW OF HIGH FIELD Q SLOPE, CAVITY MEASUREMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Gianluigi Ciovati

    2008-01-23

    One of the most interesting phenomenon occurring in superconducting radio-frequency (SRF) cavities made of bulk niobium is represented by a sharp decrease of the quality factor above peak surface magnetic field of about 90 mT and is referred to as "high field Q-slope" or "Q-drop". This phenomenon was observed first in 1997 and since then some effort was devoted to the understanding of the causes behind it. Still, no clear physical interpretation of the Q-drop has emerged, despite several attempts. In this contribution, I will review the experimental results for various cavities measured in many laboratories and I will try to identify common features and differences related to the Q-drop.

  14. Studies on the reliability of high-field intra-operative MRI in brain glioma resection

    Directory of Open Access Journals (Sweden)

    Zhi-jun SONG

    2011-07-01

    Full Text Available Objective To evaluate the reliability of high-field intra-operative magnetic resonance imaging(iMRI in detecting the residual tumors during glioma resection.Method One hundred and thirty-one cases of brain glioma(69 males and 62 females,aged from 7 to 79 years with mean of 39.6 years hospitalized from Nov.2009 to Aug.2010 were involved in present study.All the patients were evaluated using magnetic resonance imaging(MRI before the operation.The tumors were resected under conventional navigation microscope,and the high-field iMRI was used for all the patients when the operators considered the tumor was satisfactorily resected,while the residual tumor was difficult to detect under the microscope,but resected after being revealed by high-field iMRI.Histopathological examination was performed.The patients without residual tumors recieved high-field MRI scan at day 4 or 5 after operation to evaluate the accuracy of high-field iMRI during operation.Results High quality intra-operative images were obtained by using high-field iMRI.Twenty-eight cases were excluded because their residual tumors were not resected due to their location too close to functional area.Combined with the results of intra-operative histopathological examination and post-operative MRI at the early recovery stage,the sensitivity of high-field iMRI in residual tumor diagnosis was 98.0%(49/50,the specificity was 94.3%(50/53,and the accuracy was 96.1%(99/103.Conclusion High-quality intra-operative imaging could be acquired by high-field iMRI,which maybe used as a safe and reliable method in detecting the residual tumors during glioma resection.

  15. CARDIOVASCULAR DISORDERS IN ADOLESCENTS WITH CHEST PAIN

    Directory of Open Access Journals (Sweden)

    Sri Endah Rahayuningsih

    2014-06-01

    Full Text Available Objective: To detect cardiovascular abnormalities in adolescents with chest pain. Methods: In this cross sectional study, the subjects were 25 adolescents with chest pain who came to the Cardiac Center of Dr. Hasan Sadikin General Hospital, Bandung during the period of January 2008 to January 2011. The presence of established cardiovascular disorders were based on history, physical examination, electrocardiography and echocardiography Results: It was found that 13/25 adolescents with chest pain had cardiovascular abnormalities. Of the 25 teens that came with chest pain, most of which showed normal electrocardiographic results, only 9/25 of those with dysrhythmias experienced sinus tachycardia and 8 had a first degree AV block. Echocardiography examination showed only four patients with abnormal cardiac anatomy. No correlation between nutritional status and chest pain, and cardiovascular abnormalities and chest pain (p=0.206 and p=0.632, respectively. There was a positive correlation between sex and cardiovascular abnormalities in adolescents with chest pain (p=0.007. Chest pain is a prevalent problem that is usually benign and that it frequently signals underlying cardiac disease. Conclusions: Cardiovascular abnormalities in adolescents with symptoms of chest pain are found in some cases. There is no correlation between female and male adolescents with chest pain and cardiovascular abnormalities.

  16. Flail chest and pulmonary contusion.

    Science.gov (United States)

    Bastos, Renata; Calhoon, John H; Baisden, Clinton E

    2008-01-01

    Flail chest is most often accompanied by a significant underlying pulmonary parenchymal injury and can be a life-threatening thoracic injury. Its management is often complicated by the other injuries it is frequently associated with. Similarly, mortality and morbidity are dictated most often by the associated injuries and findings. Its treatment is complex and should first be one of pain management, judicious fluid resuscitation, and excellent pulmonary toilet. In those patients requiring mechanical ventilatory support, or who require ipsilateral thoracocotomy, rib stabilization may be considered depending on a host of potentially conflicting indications and contraindications. At the end of this section are listed the current major recommendations and their levels of evidence.

  17. Chest neoplasms with infectious etiologies.

    Science.gov (United States)

    Restrepo, Carlos S; Chen, Melissa M; Martinez-Jimenez, Santiago; Carrillo, Jorge; Restrepo, Catalina

    2011-12-28

    A wide spectrum of thoracic tumors have known or suspected viral etiologies. Oncogenic viruses can be classified by the type of genomic material they contain. Neoplastic conditions found to have viral etiologies include post-transplant lymphoproliferative disease, lymphoid granulomatosis, Kaposi's sarcoma, Castleman's disease, recurrent respiratory papillomatosis, lung cancer, malignant mesothelioma, leukemia and lymphomas. Viruses involved in these conditions include Epstein-Barr virus, human herpes virus 8, human papillomavirus, Simian virus 40, human immunodeficiency virus, and Human T-lymphotropic virus. Imaging findings, epidemiology and mechanism of transmission for these diseases are reviewed in detail to gain a more thorough appreciation of disease pathophysiology for the chest radiologist.

  18. Large field-of-view transmission line resonator for high field MRI

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Johannesson, Kristjan Sundgaard; Boer, Vincent;

    2016-01-01

    Transmission line resonators is often a preferable choice for coils in high field magnetic resonance imaging (MRI), because they provide a number of advantages over traditional loop coils. The size of such resonators, however, is limited to shorter than half a wavelength due to high standing wave....... Achieved magnetic field distribution is compared to the conventional transmission line resonator. Imaging experiments are performed using 7 Tesla MRI system. The developed resonator is useful for building coils with large field-of-view....

  19. Nonlinear Optimization of CLIC DRS New Design with Variable Bends and High Field Wigglers

    CERN Document Server

    Ghasem, H.; Alabau-Gonzalvo, J.; Papadopoulou, S.; Papaphilippou, Y.

    2016-01-01

    The new design of CLIC damping rings is based on longitudinal variable bends and high field superconducting wiggler magnets. It provides an ultra-low horizontal normalised emittance of 412 nm-rad at 2.86 GeV. In this paper, nonlinear beam dynamics of the new design of the damping ring (DR) with trapezium field profile bending magnets have been investigated in detail. Effects of the misalignment errors have been studied in the closed orbit and dynamic aperture.

  20. High-field Faraday rotation in II-VI-based semimagnetic semiconductors

    NARCIS (Netherlands)

    Savchuk, AI; Fediv, [No Value; Nikitin, PI; Perrone, A; Tatzenko, OM; Platonov, VV

    1998-01-01

    The effects of d-d exchange interaction have been studied by measuring high-field Faraday rotation in II-VI-based semimagnetic semiconductors. For Cd1-xMnxTe crystals with x = 0.43 and at room temperature a saturation in magnetic field dependence of the Faraday rotation has been observed. In the cas

  1. Lumbar Modic Changes - A Comparison Between Findings at Low-and High-field MRI

    DEFF Research Database (Denmark)

    Bendix, Tom; Sorensen, Joan S; Henriksson, Gustaf A C;

    2012-01-01

    Study Design. A cross-sectional observational study.Objective. To investigate if there is a difference in findings of lumbar Modic changes in low-field (0.3 Tesla) magnetic resonance imaging (MRI) as compared to high field (1.5 Tesla).Summary of Background Data. It is a challenge to give patients...

  2. High-field 3He-F interaction at the surface of fluorocarbon spheres

    DEFF Research Database (Denmark)

    Schuhl, A.; Chapellier, M.; Rasmussen, Finn Berg

    1984-01-01

    High-field experiments on the relaxation betweenF in small Teflon spheres andHe on the surface are reported. WithHe as a monolayer, coupling times are found to be less than 5 sec, in magnetic fields up to 3 T and temperatures down to 50 mK, where electronic centers are completely polarized...

  3. The design of a large aperture high field dipole

    Energy Technology Data Exchange (ETDEWEB)

    Harfoush, F.; Harrison, M.; Kerby, J.; Koepke, K.; Mantsch, P.; Nicol, T.; Riddiford, A.; Theilacker, J.

    1989-12-01

    The impetus for this design report originated in the Snowmass 88 meeting where the subject of higher energies within the constraints of the existing Tevatron tunnel enclosure was investigated. It was determined that beam transport to the fixed target experimental areas was possible up to an energy of {approximately}1.5 Tev. Collider operation was feasible at somewhat higher energies (1.8 Tev), primarily limited by the ability to design a single turn beam abort system within the constraints of the straight section length. A new accelerator in the existing tunnel would, of necessity, have a similar though not identical lattice and straight section layout to the present Tevatron. Thus when issues arose in the magnet design requiring input from the accelerator standpoint we have assumed a Tevatron like machine. The possibility of using these high field magnets as elements in the existing Tevatron to create new warm space,' for another Interaction Region for example, also emphasizes compatibility with the present machine. 16 refs., 62 figs., 23 tabs.

  4. Technique for chest compressions in adult CPR

    Directory of Open Access Journals (Sweden)

    Rajab Taufiek K

    2011-12-01

    Full Text Available Abstract Chest compressions have saved the lives of countless patients in cardiac arrest as they generate a small but critical amount of blood flow to the heart and brain. This is achieved by direct cardiac massage as well as a thoracic pump mechanism. In order to optimize blood flow excellent chest compression technique is critical. Thus, the quality of the delivered chest compressions is a pivotal determinant of successful resuscitation. If a patient is found unresponsive without a definite pulse or normal breathing then the responder should assume that this patient is in cardiac arrest, activate the emergency response system and immediately start chest compressions. Contra-indications to starting chest compressions include a valid Do Not Attempt Resuscitation Order. Optimal technique for adult chest compressions includes positioning the patient supine, and pushing hard and fast over the center of the chest with the outstretched arms perpendicular to the patient's chest. The rate should be at least 100 compressions per minute and any interruptions should be minimized to achieve a minimum of 60 actually delivered compressions per minute. Aggressive rotation of compressors prevents decline of chest compression quality due to fatigue. Chest compressions are terminated following return of spontaneous circulation. Unconscious patients with normal breathing are placed in the recovery position. If there is no return of spontaneous circulation, then the decision to terminate chest compressions is based on the clinical judgment that the patient's cardiac arrest is unresponsive to treatment. Finally, it is important that family and patients' loved ones who witness chest compressions be treated with consideration and sensitivity.

  5. Derivation of the high field semiconductor equations

    Energy Technology Data Exchange (ETDEWEB)

    Hagan, P.S. (Los Alamos National Lab., NM (United States)); Cox, R.W. (Department of Computer Information Science, Indiana University, Purdue University, Indianapolis (USA)); Wagner, B.A. (Arizona Univ., Tucson, AZ (United States). Dept. of Mathematics)

    1991-01-01

    Electron and hole densities evolve in x-z phase space according to Boltzmann equations. When the mean free path of the particles is short and electric force on the particles is weak, a well-known expansion can be used to solve the Boltzmann equation. This asymptotic solution shows that the spatial density of electrons and holes evolves according to diffusion-drift equations. As devices become smaller, electric fields become stronger, which renders the Basic Semiconductor Equations increasingly inaccurate. To remedy this problem, we use singular perturbation techniques to obtain a new asymptotic expansion for the Boltzmann equation. Like the Hilbert expansion, the new expansion requires the mean free path to be short compared to all macroscopic length scales. However, it does not require the electric forces to be weak. The new expansion shows that spatial densities obey diffusion-drift equations as before, but the diffusivity D and mobility {mu} turn out to be nonlinear functions of the electric field. In particular, our analysis determines the field-dependent mobilities {mu}(E) and diffusivities D(E) directly from the scattering operator. By carrying out this asymptotic expansion to higher order, we obtain the high frequency corrections to the drift velocity and diffusivity, and also the corrections due to gradients in the electric field. Remarkably, we find that Einsteins's relation is still satisfied, even with these corrections. The new diffusion-drift equations, together with Poissons' equation for the electric field, form the high-field semiconductor equations, which can be expected to be accurate regardless of the strength of the electric fields within the semiconductor. In addition, our analysis determines the entire momentum distribution of the particles, so we derive a very accurate first moment model for semi-conductors by substituting the asymptotically-correct distribution back into the Boltzmann equation and taking moments.

  6. Potential of ultrasound in the pediatric chest

    Energy Technology Data Exchange (ETDEWEB)

    Trinavarat, Panruethai, E-mail: pantrinavarat@hotmail.com [Department of Radiology, Faculty of Medicine, Chulalongkorn University, Rama IV Road, Pathumwan, Bangkok 10330 (Thailand); Riccabona, Michael, E-mail: michael.riccabona@klinikum-graz.at [Department of Radiology, Division of Pediatric Radiology, University Hospital Graz (Austria)

    2014-09-15

    Ultrasound (US) of chest, even with inherent limitations of the US beam and air, has been useful in many pediatric chest conditions. It has extended its role and is now widely used by many subspecialists in medicine. This review article will cover techniques, indications, and applications of chest US in neonates, infants and children, including also different common as well as some rare and modern aspects and applications, such as pleural effusion, pneumothorax, pulmonary lesions, mediastinum, diaphragm, and chest wall. Other related imaging modalities are also briefly discussed.

  7. Relevant surgical anatomy of the chest wall.

    Science.gov (United States)

    Naidu, Babu V; Rajesh, Pala B

    2010-11-01

    The chest wall, like other regional anatomy, is a remarkable fusion of form and function. Principal functions are the protection of internal viscera and an expandable cylinder facilitating variable gas flow into the lungs. Knowledge of the anatomy of the whole cylinder (ribs, sternum, vertebra, diaphragm, intercostal spaces, and extrathoracic muscles) is therefore not only important in the local environment of a specific chest wall resection but also in its relation to overall function. An understanding of chest wall kinematics might help define the loss of function after resection and the effects of various chest wall substitutes. Therefore, this article is not an exhaustive anatomic description but a focused summary and discussion.

  8. Potential of ultrasound in the pediatric chest.

    Science.gov (United States)

    Trinavarat, Panruethai; Riccabona, Michael

    2014-09-01

    Ultrasound (US) of chest, even with inherent limitations of the US beam and air, has been useful in many pediatric chest conditions. It has extended its role and is now widely used by many subspecialists in medicine. This review article will cover techniques, indications, and applications of chest US in neonates, infants and children, including also different common as well as some rare and modern aspects and applications, such as pleural effusion, pneumothorax, pulmonary lesions, mediastinum, diaphragm, and chest wall. Other related imaging modalities are also briefly discussed.

  9. Threats to ultra-high-field MRI

    Science.gov (United States)

    Le Bihan, Denis

    2009-08-01

    In 2004 the European Commission (EC) adopted a directive restricting occupational exposure to electromagnetic fields. This directive (2004/40/CE), which examines the possible health risks of the electromagnetic fields from mobile phones, Wi-Fi, Bluetooth and other devices, concluded that upper limits on radiation and applied electromagnetic fields are necessary to prevent workers from suffering any undue acute health effects. But although not initially intended, the biggest impact of the directive could be on magnetic resonance imaging (MRI), which is used in hospitals worldwide to produce images of unrivalled quality of the brain and other soft tissues.

  10. Remote interpretation of chest roentgenograms.

    Science.gov (United States)

    Andrus, W S; Hunter, C H; Bird, K T

    1975-04-01

    A series of 98 chest films was interpreted by two physicians on the basis of monitor display of the transmitted television signal representing the roentgenographic image. The transmission path was 14 miles long, and included one active repeater station. Receiver operating characteristic curves were drawn to compare interpretations rendered on television view of the image with classic, direct view interpretations of the same films. Performance in these two viewing modes was found to be quite similar. When films containing only hazy densities lacking internal structure or sharp margins, were removed from the sample, interpretation of the remaining films was essentially identical via the two modes. Since hazy densities are visible on retrospective examination, interpretation of roentgenograms at a distance via television appears to be a feasible route for delivery of radiologic services.

  11. Examination of musculoskeletal chest pain

    DEFF Research Database (Denmark)

    Brunse, Mads Hostrup; Stochkendahl, Mette Jensen; Vach, Werner

    2010-01-01

    using a standardized examination protocol, (2) to determine inter-observer reliability of single components of the protocol, and (3) to determine the effect of observer experience. Eighty patients were recruited from an emergency cardiology department. Patients were eligible if an obvious cardiac or non......-cardiac diagnosis could not be established at the cardiology department. Four observers (two chiropractors and two chiropractic students) performed general health and manual examination of the spine and chest wall. Percentage agreement, Cohen's Kappa and ICC were calculated for observer pairs (chiropractors.......01 to 0.59. Provided adequate training of observers, the examination protocol can be used in carefully selected patients in clinical settings and should be included in pre- and post-graduate clinical training....

  12. Chest pain and exacerbations of bronchiectasis

    Directory of Open Access Journals (Sweden)

    King PT

    2012-12-01

    Full Text Available Paul T King,1,2 Stephen R Holdsworth,2 Michael Farmer,1 Nicholas J Freezer,1 Peter W Holmes11Department of Respiratory and Sleep Medicine, 2Monash University Department of Medicine, Monash Medical Centre, Melbourne, Victoria, AustraliaBackground: Bronchiectasis is a common disease and a major cause of respiratory morbidity. Chest pain has been described as occurring in the context of bronchiectasis but has not been well characterized. This study was performed to describe the characteristics of chest pain in adult bronchiectasis and to define the relationship of this pain to exacerbations.Subjects and methods: We performed a prospective study of 178 patients who were followed-up for 8 years. Subjects were reviewed on a yearly basis and assessed for the presence of chest pain. Subjects who had chest pain at the time of clinical review by the investigators were included in this study. Forty-four patients (25% described respiratory chest pain at the time of assessment; in the majority of cases 39/44 (89%, this occurred with an exacerbation and two distinct types of chest pain could be described: pleuritic (n = 4 and non-pleuritic (n = 37, with two subjects describing both forms. The non-pleuritic chest pain occurred most commonly over both lower lobes and was mild to moderate in severity. The pain subsided as patients recovered. Conclusion: Non-pleuritic chest pain occurs in subjects with bronchiectasis generally in association with exacerbations.Keywords: sputum, collapse, bronchitis, airway obstruction

  13. Alternative Approach to the Provision of the High-field Dipole for FCC-hh

    CERN Document Server

    AUTHOR|(SzGeCERN)435046

    2015-01-01

    This paper describes a possible approach to reducing the complexity and cost of the high field dipole magnets. In addition the cooling of the winding could be improved in the proposed design, with a consequent reduction in the shielding requirements. The correction of multipoles is also addressed: this feature may impact on the dynamic range of operation of the magnets. Noting that it would be possible to add a small gradient component to the dipole, it is suggested that a (partially) combined function lattice should be considered. The proposals lead to a brief re-appraisal of how best to apply superconductivity to magnets for large accelerators.

  14. Solitary Plasmacytoma of the Chest Wall

    Directory of Open Access Journals (Sweden)

    Servet Kayhan

    2014-03-01

    Full Text Available A previously healthy 55-year-old man with right sided lateral chest pain admitted to clinic. It was found a solid and painful mass at the right 4th rib in physical examination. Chest X-ray and thoracic computarized tomography showed an opacity measured 60x33 mm within the right chest wall destructing the 4th rib. Needle aspiration was performed from tumor and cytologic examination showed atypic plasma cell infiltration. The patient was scheduled for a chest wall resection and reconstructive surgery. Examination of a permanent section showed that the chest wall tumor was solitary plasmacytoma. There was no evidence of multiple myeloma recurrence after two years from the operation.

  15. 3.0T高场强核磁共振设备机房布局及施工准备%Research on the layout and construction preparation for 3.0T high-field nuclear magnetic resonance equipment room

    Institute of Scientific and Technical Information of China (English)

    孙继江; 何晓彬; 步岩生

    2013-01-01

    目的:通过对3.0T核磁共振设备机房施工前期的合理布局、充分准备,缩短了施工时间,使得后期使用安全便捷,为医院节约了资金。方法:根据医院具体特点,在选址时充分考虑运输、配电、通风、承重及电磁干扰等问题,逐步进行落实、做好施工准备。结果:机房选址要求承重在10t以上、磁体中心点3 m内铁磁物质要做评估,周围移动的汽车及变压器必须在3G线以外,要求有专用变压器且容量>150 kVA。设备接地电阻<2Ω,屏蔽房对地绝缘>1000Ω。失超管高出地面3.8 m以上,周围不能有空调进风口。水冷机通风良好,北方地区还要做好室外机的冬季防冻。磁体间排风按每小时换气≥12次设计。结论:医院大型设备施工准备及辅助设备安装过程中的各个环节要匹配合理,同时注重和不同单位之间的协作。合理的设备布局和施工准备,是设备顺利安装的保证。%Objective:To do the research on the layout and construction preparation for 3.0T high-field nuclear magnetic resonance equipment room, greatly shorten the construction time and save money for hospital by the safe and convenient usage. Methods: According to the specific characteristics of hospital sitting in full consideration of transportation and distribution, ventilation, bearing, electromagnetic interference and so on, we implement gradually, were ready to work in the construction. Results: Computer room location requirements bearing within 10 tons, magnets, center of 3 m in ferromagnetic material to do assessment, and moving around the car and the transformer must be beyond 3G line, required a special transformer and the capacity of more than 150 kVA. Equipment grounding resistance is less than 2 ohms, shielding room of insulation is greater than 1000 ohms. Super tube is higher than 3.8 m above the ground, there be no air conditioning air inlet. Water-cooled machine well

  16. The value of conventional high-field MRI in MS in the light of the McDonald criteria: a literature review

    DEFF Research Database (Denmark)

    Larsen, Line Sofie Lunde; Larsson, H B W; Frederiksen, Jette Lautrup Battistini

    2010-01-01

    The diagnosis of MS is based on the revised McDonald criteria and is multidisciplinary. Both clinical and paraclinical measures are included. High-field magnetic resonance imaging (MRI) is becoming increasingly available and it is therefore necessary to clarify possible advantages of high-field MRI...... of lesions to be better at high field. Of the seven studies, six found more and bigger lesions at high-field MRI. In the present paper, the relevant MRI sequences are evaluated in detail. The detection of more lesions at high-field strength did not seem to lead to earlier diagnosis of clinically definite...

  17. [Chest pains in the dental environment].

    Science.gov (United States)

    Garfunkel, A; Galili, D; Findler, M; Zusman, S P; Malamed, S F; Elad, S; Kaufman, E

    2002-01-01

    Chest pain does not necessarily indicate cardiac disease. The most common causes of acute chest pain encountered in dental situations include hyperventilation, pulmonary embolism, angina pectoris and myocardial infarction. Stress and fear often cause rapid breathing or hyperventilation. This usually occurs in young adults and although the hyperventilating patient often complains of chest pain, this is rarely a manifestation of cardiac disease. Pulmonary embolism usually indicates the occlusion of a pulmonary artery causing severe chest pain. The primary clinical manifestation of angina pectoris is chest pain. Although most instances of anginal pain are easily terminated, the dentist must always consider the possibility that the supposed anginal attack is actually a sign of acute myocardial infarction (AMI). AMI is a clinical syndrome caused by a deficient coronary arterial blood supply to a region of myocardium that results in cellular death. There is a high incidence of mortality among AMI with death often occurring within 2 hours of the onset of signs and symptoms. The initial clinical manifestations of all types of chest pain can be similar. Therefore the dentist must develop proficiency in constituting a differential diagnosis and an efficient management protocol. As in most medical situations prevention is the most powerful tool. However, if chest pains do occur, measures such as airway management, oxygen supplementation, coronary artery dilation, analgesis and in extreme cases, cardiopulmonary resuscitation and evacuation to the emergency room, may be necessary.

  18. Chest CT in children: anesthesia and atelectasis

    Energy Technology Data Exchange (ETDEWEB)

    Newman, Beverley; Gawande, Rakhee [Lucile Packard Children' s Hospital, Department of Radiology, Stanford, CA (United States); Krane, Elliot J. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Anesthesiology, Perioperative and Pain Medicine, Stanford, CA (United States); Holmes, Tyson H. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Psychiatry and Behavioral Sciences, Stanford, CA (United States); Robinson, Terry E. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Pulmonary Medicine and Cystic Fibrosis Center for Excellence in Pulmonary Biology, Stanford, CA (United States)

    2014-02-15

    There has been an increasing tendency for anesthesiologists to be responsible for providing sedation or anesthesia during chest CT imaging in young children. Anesthesia-related atelectasis noted on chest CT imaging has proven to be a common and troublesome problem, affecting image quality and diagnostic sensitivity. To evaluate the safety and effectiveness of a standardized anesthesia, lung recruitment, controlled-ventilation technique developed at our institution to prevent atelectasis for chest CT imaging in young children. Fifty-six chest CT scans were obtained in 42 children using a research-based intubation, lung recruitment and controlled-ventilation CT scanning protocol. These studies were compared with 70 non-protocolized chest CT scans under anesthesia taken from 18 of the same children, who were tested at different times, without the specific lung recruitment and controlled-ventilation technique. Two radiology readers scored all inspiratory chest CT scans for overall CT quality and atelectasis. Detailed cardiorespiratory parameters were evaluated at baseline, and during recruitment and inspiratory imaging on 21 controlled-ventilation cases and 8 control cases. Significant differences were noted between groups for both quality and atelectasis scores with optimal scoring demonstrated in the controlled-ventilation cases where 70% were rated very good to excellent quality scans compared with only 24% of non-protocol cases. There was no or minimal atelectasis in 48% of the controlled ventilation cases compared to 51% of non-protocol cases with segmental, multisegmental or lobar atelectasis present. No significant difference in cardiorespiratory parameters was found between controlled ventilation and other chest CT cases and no procedure-related adverse events occurred. Controlled-ventilation infant CT scanning under general anesthesia, utilizing intubation and recruitment maneuvers followed by chest CT scans, appears to be a safe and effective method to obtain

  19. Condromalácia de patela: comparação entre os achados em aparelhos de RM de alto e baixo campo magnético Chondromalacia patellae: comparison of high-field strength versus low-field strength magnetic resonance imaging findings

    Directory of Open Access Journals (Sweden)

    Maxime Figueiredo de Oliveira Freire

    2006-06-01

    Full Text Available OBJETIVO: Comparar os aparelhos de ressonância magnética de baixo campo e de alto campo para estudo da cartilagem articular da patela. MATERIAIS E MÉTODOS: Foi realizado estudo usando as seqüências GRE 2D, GRE 3D, FSE T2 e STIR (baixo campo e TSE T2 SPIR. Cada seqüência foi analisada separadamente para o estudo da cartilagem, sem o conhecimento dos dados do paciente e do resultado das outras seqüências, sendo atribuído grau de lesão de 0 a 3 e descrita a sua localização. Os resultados de concordância e discordância foram analisados pelos testes de Kappa e McNemar. RESULTADOS: Na faceta medial houve baixas concordâncias e as discordâncias mostraram significativa superestimação. Na faceta lateral houve boas concordâncias e as discordâncias não foram significativas. No ápice houve boas concordâncias e as discordâncias mostraram significativa subestimação. CONCLUSÃO: A seqüência STIR teve a melhor concordância com a seqüência TSE T2 SPIR. Lesões de alto grau são mais bem caracterizadas pelas seqüências do aparelho de baixo campo. Áreas de aumento de sinal dificultam o estudo da cartilagem da faceta medial da patela no aparelho de baixo campo.OBJECTIVE: To compare the performance of low-field-strength and high-field-strength magnetic resonance imaging equipments for evaluation of the patella articular cartilage. MATERIALS AND METHODS: The study was developed using GRE 2D, GRE 3D, FSE T2, STIR sequences (low-field and TSE T2 SPIR sequence. Each sequence has been separately analyzed for evaluation of the cartilage without knowledge of other sequences results or any patients data; the lesion was assigned a grade from 0 to 3 and had its location defined. Agreement and disagreement results were analyzed by Kappa and McNemar tests. RESULTS: Medial facet has presented low agreement index and disagreements showed to be significantly overestimated. Lateral facet has presented a reasonable agreement index and disagreement

  20. Chest pain: a time for concern?

    Science.gov (United States)

    King, Joan E; Magdic, Kathy S

    2014-01-01

    When a patient complains of chest pain, the first priority is to establish whether the situation is life threatening. Life-threatening differential diagnoses that clinicians must consider include acute coronary syndrome, cardiac tamponade, pulmonary embolus, aortic dissection, and tension pneumothorax. Nonthreatening causes of chest pain that should be considered include spontaneous pneumothorax, pleural effusion, pneumonia, valvular diseases, gastric reflux, and costochondritis. The challenge for clinicians is not to be limited by "satisfaction of search" and fail to consider important differential diagnoses. The challenge, however, can be met by developing a systematic method to assess chest pain that will lead to the appropriate diagnosis and appropriate treatment plan.

  1. Chest pain of cardiac and noncardiac origin.

    Science.gov (United States)

    Lenfant, Claude

    2010-10-01

    Chest pain is one of the most common symptoms driving patients to a physician's office or the hospital's emergency department. In approximately half of the cases, chest pain is of cardiac origin, either ischemic cardiac or nonischemic cardiac disease. The other half is due to noncardiac causes, primarily esophageal disorder. Pain from either origin may occur in the same patient. In addition, psychological and psychiatric factors play a significant role in the perception and severity of the chest pain, irrespective of its cause. Chest pain of ischemic cardiac disease is called angina pectoris. Stable angina may be the prelude of ischemic cardiac disease; and for this reason, it is essential to ensure a correct diagnosis. In most cases, further testing, such as exercise testing and angiography, should be considered. The more severe form of chest pain, unstable angina, also requires a firm diagnosis because it indicates severe coronary disease and is the earliest manifestation of acute myocardial infarction. Once a diagnosis of stable or unstable angina is established, and if a decision is made not to use invasive therapy, such as coronary bypass, percutaneous transluminal coronary angioplasty, or stent insertion, effective medical treatment of associated cardiac risk factors is a must. Acute myocardial infarction occurring after a diagnosis of angina greatly increases the risk of subsequent death. Chest pain in women warrants added attention because women underestimate their likelihood to have coronary heart disease. A factor that complicates the clinical assessment of patients with chest pain (both cardiac and noncardiac in origin) is the relatively common presence of psychological and psychiatric conditions such as depression or panic disorder. These factors have been found to cause or worsen chest pain; but unfortunately, they may not be easily detected. Noncardiac chest pain represents the remaining half of all cases of chest pain. Although there are a number of

  2. Common Acupoints in Chest and Abdomen

    Institute of Scientific and Technical Information of China (English)

    Journal of Acupuncture and Tuina Science Editor; CUI Xue-jun

    2003-01-01

    @@ Tiantu (CV 21) Location: In the center of the suprasternal fossa(Fig. l ). Indications: Cough, dyspnea, chest pain, pharyngolaryngeal swelling and pains, sudden hoarseness of the voice, goiter, globus hystericus, and dysphagia.

  3. Tuberculosis, advanced - chest x-rays (image)

    Science.gov (United States)

    Tuberculosis is an infectious disease that causes inflammation, the formation of tubercules and other growths within tissue, ... death. These chest x-rays show advanced pulmonary tuberculosis. There are multiple light areas (opacities) of varying ...

  4. Apparatus and method for magnetically processing a specimen

    Science.gov (United States)

    Ludtka, Gerard M; Ludtka, Gail M; Wilgen, John B; Kisner, Roger A; Jaramillo, Roger A

    2013-09-03

    An apparatus for magnetically processing a specimen that couples high field strength magnetic fields with the magnetocaloric effect includes a high field strength magnet capable of generating a magnetic field of at least 1 Tesla and a magnetocaloric insert disposed within a bore of the high field strength magnet. A method for magnetically processing a specimen includes positioning a specimen adjacent to a magnetocaloric insert within a bore of a magnet and applying a high field strength magnetic field of at least 1 Tesla to the specimen and to the magnetocaloric insert. The temperature of the specimen changes during the application of the high field strength magnetic field due to the magnetocaloric effect.

  5. CARDIOVASCULAR DISORDERS IN ADOLESCENTS WITH CHEST PAIN

    OpenAIRE

    Sri Endah Rahayuningsih; Rahmat Budi; Herry Garna

    2014-01-01

    Objective: To detect cardiovascular abnormalities in adolescents with chest pain. Methods: In this cross sectional study, the subjects were 25 adolescents with chest pain who came to the Cardiac Center of Dr. Hasan Sadikin General Hospital, Bandung during the period of January 2008 to January 2011. The presence of established cardiovascular disorders were based on history, physical examination, electrocardiography and echocardiography Results: It was found that 13/25 adolesce...

  6. Relevant surgical anatomy of the chest wall

    OpenAIRE

    Rajesh, Pala Babu; Naidu, Babu V.

    2010-01-01

    The chest wall, like other regional anatomy, is a remarkable fusion of form and function. Principal functions are the protection of internal viscera and an expandable cylinder facilitating variable gas flow into the lungs. Knowledge of the anatomy of the whole cylinder (ribs, sternum, vertebra, diaphragm, intercostal spaces, and extrathoracic muscles) is therefore not only important in the local environment of a specific chest wall resection but also in its relation to overall function. An un...

  7. Proceedings of the sixth Japan--US workshop on high-field superconducting materials and standard procedures for high-field superconducting materials testing

    Energy Technology Data Exchange (ETDEWEB)

    Tachikawa, K. (ed.) (Tokai Univ., Kanagawa (Japan). Faculty of Engineering); Yamafuji, K. (ed.) (Kyushu Univ., Fukuoka (Japan). Dept. of Electronics); Wada, H. (ed.) (National Research Inst. for Metals, Tsukuba, Ibaraki (Japan)); Ekin, J.W. (ed.) (National Inst. of Standards and Technology, Boulder, CO (United States)); Suenaga, M. (ed.) (Brookhaven National Lab., Upton, NY (United States))

    1989-01-01

    High critical current densities and high magnetic fields are needed for most important energy application of both conventional and high-Tc superconductors. This workshop brought together those engaged research on high-field superconductors in Japan and the US to present recent research results on performance of new high-field superconducting materials and to discuss the most promising directions for research, specifically as it relates to the fusion energy needs of both countries. Topics covered included critical currents, irradiation effects, ac losses, magnetization properties, and new fabrication processes for conventional superconductors. An entire session was devoted to presentations on the properties of Nb[sub 3]Al superconductors. Large magnet research programs for energy applications were reviewed, including the tokamak fusion machine at JAERI, the joint US-Japan Nb[sub 3]Sn poloidal-field-coll development program, and the proposed International Thermonuclear Experimental Reactor (ITER) project. Results were also presented on the VAMAS round robin in three areas; J[sub c], stress effects, and ac losses. Finally, some current research results on experimental high-[Tc] superconductors were reviewed, with particular emphasis on new fabrication processes and the factors limiting the critical current in high-current conductors. Separate abstracts have been prepared.

  8. Proceedings of the sixth Japan--US workshop on high-field superconducting materials and standard procedures for high-field superconducting materials testing

    Energy Technology Data Exchange (ETDEWEB)

    Tachikawa, K. [ed.] [Tokai Univ., Kanagawa (Japan). Faculty of Engineering; Yamafuji, K. [ed.] [Kyushu Univ., Fukuoka (Japan). Dept. of Electronics; Wada, H. [ed.] [National Research Inst. for Metals, Tsukuba, Ibaraki (Japan); Ekin, J.W. [ed.] [National Inst. of Standards and Technology, Boulder, CO (United States); Suenaga, M. [ed.] [Brookhaven National Lab., Upton, NY (United States)

    1989-12-31

    High critical current densities and high magnetic fields are needed for most important energy application of both conventional and high-Tc superconductors. This workshop brought together those engaged research on high-field superconductors in Japan and the US to present recent research results on performance of new high-field superconducting materials and to discuss the most promising directions for research, specifically as it relates to the fusion energy needs of both countries. Topics covered included critical currents, irradiation effects, ac losses, magnetization properties, and new fabrication processes for conventional superconductors. An entire session was devoted to presentations on the properties of Nb{sub 3}Al superconductors. Large magnet research programs for energy applications were reviewed, including the tokamak fusion machine at JAERI, the joint US-Japan Nb{sub 3}Sn poloidal-field-coll development program, and the proposed International Thermonuclear Experimental Reactor (ITER) project. Results were also presented on the VAMAS round robin in three areas; J{sub c}, stress effects, and ac losses. Finally, some current research results on experimental high-{Tc} superconductors were reviewed, with particular emphasis on new fabrication processes and the factors limiting the critical current in high-current conductors. Separate abstracts have been prepared.

  9. X-ray powder diffraction camera for high-field experiments

    Energy Technology Data Exchange (ETDEWEB)

    Koyama, K; Mitsui, Y; Takahashi, K; Watanabe, K [High Field Laboratory for Superconducting Materials, Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan)], E-mail: kkoyama@imr.tohoku.ac.jp

    2009-03-01

    We have designed a high-field X-ray diffraction (HF-XRD) camera which will be inserted into an experimental room temperature bore (100 mm) of a conventional solenoid-type cryocooled superconducting magnet (10T-CSM). Using the prototype camera that is same size of the HF-XRD camera, a XRD pattern of Si is taken at room temperature in a zero magnetic field. From the obtained results, the expected ability of the designed HF-XRD camera is presented.

  10. Psychiatric syndromes associated with atypical chest pain

    Directory of Open Access Journals (Sweden)

    Nikolić Gordana

    2010-01-01

    Full Text Available Background/Aim. Chest pain often indicates coronary disease, but in 25% of patients there is no evidence of ischemic heart disease using standard diagnostic tests. Beside that, cardiologic examinations are repeated several times for months. If other medical causes could not be found, there is a possibility that chest pain is a symptom of psychiatric disorder. The aim of this study was to determine the presence of psychiatric syndromes, increased somatization, anxiety, stress life events exposure and characteristic of chest pain expression in persons with atypical chest pain and coronary patients, as well as to define predictive parameters for atypical chest pain. Method. We compared 30 patients with atypical chest pain (E group to 30 coronary patients (K group, after cardiological and psychiatric evaluation. We have applied: Mini International Neuropsychiatric Interview (MINI, The Symptom Checklist 90-R (SCL-90 R, Beck Anxiety Inventory (BAI, Holms-Rahe Scale of stress life events (H-R, Questionnaire for pain expression Pain-O-Meter (POM. Significant differences between groups and predictive value of the parameters for atypical chest pain were determined. Results. The E group participants compared to the group K were younger (33.4 ± 5.4 : 48.3 ± 6,4 years, p < 0.001, had a moderate anxiety level (20.4 ± 11.9 : 9.6 ± 3.8, p < 0.001, panic and somatiform disorders were present in the half of the E group, as well as eleveted somatization score (SOM ≥ 63 -50% : 10%, p < 0.01 and a higher H-R score level (102.0 ± 52.2 : 46.5 ± 55.0, p < 0.001. Pain was mild, accompanied with panic. The half of the E group subjects had somatoform and panic disorders. Conclusion. Somatoform and panic disorders are associated with atypical chest pain. Pain expression is mild, accompained with panic. Predictive factors for atypical chest pain are: age under 40, anxiety level > 20, somatization ≥ 63, presence of panic and somatoform disorders, H-R score > 102

  11. Radiographic, CT and MRI spectrum of hydatid disease of the chest: a pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Sinner, W.N. von [Dept. of Radiology MBC28, King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia)

    1993-01-01

    Thirty patients with thoracic hydatidosis (Echinococcus granulosus) were studied. The hydatid cysts were located in the lung parenchyma (70%), mediastinum (6.7%), inside the heart (10%), the pleurae (10%) and the chest wall (3.3%). Complications of thoracic hydatid cysts, such as rupture, infection, pleural involvement, spread and calcifications are presented. Computed tomography (CT) without and/or with contrast enhancement was performed in all patients (30). Findings from conventional chest radiographs were compared with CT and confirmed by pathology (30). In 10 cases (33.3%), magnetic resonance imaging was also performed. The diagnostic spectrum of hydatid cysts, including variations and developmental stages, is presented in this pictorial essay. (orig.)

  12. Radiation induced osteosarcoma of the chest wall

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, Tsutomu; Yuki, Yoshihiro; Oizumi, Hiroyuki; Iijima, Yoshiyuki; Fujishima, Tsukasa; Shimazaki, Yasuhisa [Yamagata Univ. (Japan). School of Medicine

    1996-11-01

    We report a successful resection of an osteosarcoma in the chest wall developed 25 years after irradiation. A 74-year-old woman was admitted to our hospital for her swelling in the left chest wall at August 24, 1995. At 49-year-old, she had undergone an operation and postoperative irradiation for left breast cancer. A computed tomography demonstrated a mass in the left chest wall that destructed the first rib, extending into the pleural space and invaded into the left common carotid and subclavian arteries. We planned a radical resection of the mass after repeated CT scannings, since it was histopathologically diagnosed as a chondrosarcoma and showed a rapid growth. The tumor was completely removed with radical transmediastinal forequarter amputation of the partial chest wall and total left upper extremity. The left common carotid artery was partially replaced with 6 mm EPTFE vascular prosthesis. The chest wall was reconstructed with Marlex-mesh prosthesis and a myocutaneous flap. She was discharged uneventfully and has not shown any evidence of recurrence. (author)

  13. Understanding the dynamics of superparamagnetic particles under the influence of high field gradient arrays

    Science.gov (United States)

    Barnsley, Lester C.; Carugo, Dario; Aron, Miles; Stride, Eleanor

    2017-03-01

    The aim of this study was to characterize the behaviour of superparamagnetic particles in magnetic drug targeting (MDT) schemes. A 3-dimensional mathematical model was developed, based on the analytical derivation of the trajectory of a magnetized particle suspended inside a fluid channel carrying laminar flow and in the vicinity of an external source of magnetic force. Semi-analytical expressions to quantify the proportion of captured particles, and their relative accumulation (concentration) as a function of distance along the wall of the channel were also derived. These were expressed in terms of a non-dimensional ratio of the relevant physical and physiological parameters corresponding to a given MDT protocol. The ability of the analytical model to assess magnetic targeting schemes was tested against numerical simulations of particle trajectories. The semi-analytical expressions were found to provide good first-order approximations for the performance of MDT systems in which the magnetic force is relatively constant over a large spatial range. The numerical model was then used to test the suitability of a range of different designs of permanent magnet assemblies for MDT. The results indicated that magnetic arrays that emit a strong magnetic force that varies rapidly over a confined spatial range are the most suitable for concentrating magnetic particles in a localized region. By comparison, commonly used magnet geometries such as button magnets and linear Halbach arrays result in distributions of accumulated particles that are less efficient for delivery. The trajectories predicted by the numerical model were verified experimentally by acoustically focusing magnetic microbeads flowing in a glass capillary channel, and optically tracking their path past a high field gradient Halbach array.

  14. Understanding the dynamics of superparamagnetic particles under the influence of high field gradient arrays.

    Science.gov (United States)

    Barnsley, Lester C; Carugo, Dario; Aron, Miles; Stride, Eleanor

    2017-03-21

    The aim of this study was to characterize the behaviour of superparamagnetic particles in magnetic drug targeting (MDT) schemes. A 3-dimensional mathematical model was developed, based on the analytical derivation of the trajectory of a magnetized particle suspended inside a fluid channel carrying laminar flow and in the vicinity of an external source of magnetic force. Semi-analytical expressions to quantify the proportion of captured particles, and their relative accumulation (concentration) as a function of distance along the wall of the channel were also derived. These were expressed in terms of a non-dimensional ratio of the relevant physical and physiological parameters corresponding to a given MDT protocol. The ability of the analytical model to assess magnetic targeting schemes was tested against numerical simulations of particle trajectories. The semi-analytical expressions were found to provide good first-order approximations for the performance of MDT systems in which the magnetic force is relatively constant over a large spatial range. The numerical model was then used to test the suitability of a range of different designs of permanent magnet assemblies for MDT. The results indicated that magnetic arrays that emit a strong magnetic force that varies rapidly over a confined spatial range are the most suitable for concentrating magnetic particles in a localized region. By comparison, commonly used magnet geometries such as button magnets and linear Halbach arrays result in distributions of accumulated particles that are less efficient for delivery. The trajectories predicted by the numerical model were verified experimentally by acoustically focusing magnetic microbeads flowing in a glass capillary channel, and optically tracking their path past a high field gradient Halbach array.

  15. Prephonatory chest wall posturing in stutterers.

    Science.gov (United States)

    Baken, R J; McManus, D A; Cavallo, S A

    1983-09-01

    The possibility that prephonatory chest wall posturing is abnormal in stutterers was explored by observing rib cage and abdominal hemicircumference changes during the interval between the presentation of a stimulus and the production of/alpha/by a group of stutterers (N = 5). It was found that the patterns of chest wall adjustment for phonation were qualitatively identical in the stutterers and in a comparable group of normal men studied previously. There was, however, a significant difference in the way in which lung volume changed during the execution of the chest wall adjustment. This was considered to be indicative of delayed glottal closure among the stutterers rather than representative of a primary ventilatory disturbance.

  16. Cardiogenic shock following blunt chest trauma

    Directory of Open Access Journals (Sweden)

    Rodríguez-González Fayna

    2010-01-01

    Full Text Available Cardiac contusion, usually caused by blunt chest trauma, has been recognized with increased frequency over the past decades. Traffic accidents are the most frequent cause of cardiac contusions resulting from a direct blow to the chest. Other causes of blunt cardiac injury are numerous and include violent fall impacts, interpersonal aggression, explosions, and various types of high-risk sports. Myocardial contusion is difficult to diagnose; clinical presentation varies greatly, ranging from lack of symptoms to cardiogenic shock and arrhythmia. Although death is rare, cardiac contusion can be fatal. We present a case of cardiac contusion due to blunt chest trauma secondary to a fall impact, which manifested as cardiogenic shock.

  17. [Chest wall mesenchymal hamartoma: a case report].

    Science.gov (United States)

    Morales, Olga Lucía; Valencia, María de la Luz; Gómez, Carolina; Pérez, María del Pilar; Sanín, Emilio; Vásquez, Luz Marina

    2010-01-01

    Chest wall mesenchymal hamartoma is an extremely rare benign tumor. Approximately 80 cases have been reported in the literature. Most tumors are manifested at birth with a painless palpable mass of the chest wall, usually unilateral. Respiratory symptoms result from extrinsic compression of the pulmonary parenchyma, and the severity of the symptoms will depend on the size and location of the lesion. Imaging features are characteristic, but definitive diagnosis is histological. Herein, a case is described of a four month old infant with diagnosis of chest wall mesenchymal hamartoma, manifested at birth. Different treatment options are described, including expectations from tumor management, the possibility of spontaneous regression, and the morbidity associated with the surgical option.

  18. Misdiagnosed Chest Pain: Spontaneous Esophageal Rupture

    Science.gov (United States)

    Inci, Sinan; Gundogdu, Fuat; Gungor, Hasan; Arslan, Sakir; Turkyilmaz, Atila; Eroglu, Atila

    2013-01-01

    Chest pain is one of themost common complaints expressed by patients presenting to the emergency department, and any initial evaluation should always consider life-threatening causes. Esophageal rupture is a serious condition with a highmortality rate. If diagnosed, successful therapy depends on the size of the rupture and the time elapsed between rupture and diagnosis.We report on a 41-year-old woman who presented to the emergency department complaining of left-sided chest pain for two hours. PMID:27122690

  19. Chest wall abscess due to Prevotella bivia

    Institute of Scientific and Technical Information of China (English)

    Gwo-jong HSU; Cheng-ren CHEN; Mei-chu LAI; Shi-ping LUH

    2009-01-01

    Prevotella bivia is associated with pelvic inflammatory disease. A 77-year-old man developed a rapidly growing chest wall abscess due to P. Bivia within days. He underwent surgical resection of the infected area; his postoperative course was un-eventful. This is the first case of chest wall abscess due to P. Bivia infection. Its correct diagnosis cannot be underestimated be-cause fulminam infections can occur in aged or immunocompromised patients if treated incorrectly. Prompt, appropriate surgical management, and antibiotic therapy affect treatment outcome.

  20. 高场强术中磁共振成像及神经导航在累及视放射的颞叶胶质瘤手术中的应用%Intraoperative high-field magnetic resonance imaging combined with functional neuronavigation in resection of low-grade temporal lobe tumors involving optic radiation

    Institute of Scientific and Technical Information of China (English)

    白少聪; 陈晓雷; 耿杰峰; 吴东东; 余新光; 许百男

    2015-01-01

    Objective To investigate the clinical value of high-field-strength intraoperative magnetic resonance imaging (iMRI) combined with optic radiation neuro-navigation for the resection of temporal lobe low-grade gliomas.Methods From April 2009 to September 2013,65 patients with temporal lobe lowgrade gliomas (WHO grade Ⅱ) involving optic radiation were operated with iMRI and functional neuronavigation.Diffusion tensor imaging (DTI) based fiber tracking was used to delineate optic radiation.The reconstructed optic radiations were integrated into a navigation system,in order to achieve intraoperative microscopic-based functional neuro-navigation,iMRI was used to update the images for both optic radiations and residual tumors.Volumetric analyses were performed using 3D Slicer for pre-and intra-operative tumor volumes in all cases.All patients were evaluated for visual field deficits preoperatively and postoperatively.The Student t test was used to evaluate the average rate of extent of resection between groups.Spearman rank correlation analysis was used to assess correlations between predictors and epilepsy prognosis.Results Preoperative tumor volumes were (78 ±40) cm3.In 29 cases,iMRI scan detected residual tumor that could be further resected,and extent of resection were increased from 76.2% to 92.7% (t =7.314,P <0.01).In 19 cases (29.2%),gross total resection was accomplished,and iMRI contributed directly to 8 of these cases.Postsurgical follow-up period varied from 13 months to 59 months,mean (33 ± 13) months.Tumor progression were observed in 3 patients,newly developed or deteriorated visual field defects occurred in 4 patients (6.2%).For patients with pre-operative seizures,Engel Class Ⅰ were achieved for 89.7% of them.Spearman rank correlation analysis revealed that seizure outcome (Engel Class) was related to increased excision of ratio (r =-0.452,P =0.004,95% CI:-0.636--0.261) and larger tumors (r =0.391,P =0.014,95% CI:0

  1. Diagnosis and Treatment of Chest Injury and Emergency Diseases of Chest Organs

    Directory of Open Access Journals (Sweden)

    A. M. Khadjibaev

    2016-01-01

    Full Text Available Goal of research: to evaluate efficiency of videothoracoscopy in diagnosis and treatment of patients with injuries and emergency diseases ща chest organs.Material and methods: Study wasbased on treatment results analysis of 2111 patients with injuries and chest organs emergency diseases, who were treated at Republican Research Centre of Emergency Medicine in 2001-2014. Chest trauma made up 1396 (66,1% victims. There were 477 (22,6% patients with spontaneous pneumothorax. At the stages of initial diagnosis, the radiologic evaluations, CT investigations and videothoracoscopies were performed. In chest trauma patients the videothoracoscopy underwent in 844 cases, in spontaneous pneu#mothorax this method was employed in 290 patients. Complicated forms of lung echinococcosis were observed in 238 (11,3% patients and complicated forms of lung echinococcosis were evident in 72 patients.Results. Videothoracoscopy and video-assisted interventions allowed to eliminate lungs and pleura pathology in 1206 (57,1% patients, whereas the traditional methods were effective only in 905 cases (42,9%.Conclusions. Investigation methods such as multiplanar radioscopy, radiography, chest CT and videothora-coscopy must be included into algorithm of diagnosis and surgical treatment of chest injuries and emergency diseases of chest organs. At chest trauma the videothoracoscopy allows to avoid broad thoracotomy from 9,4% to 4,7% of cases, to reduce the frequency of repeated interventions from 17,4% to 0,5% and diminish a number of early postsurgery complications from 25,4% to 10,9%. Videothoracoscopy of chest traumas allows to reduce frequency of repeated interventions from 19,8 to 1,7%.

  2. High field transport properties of MBE processed Fe-based superconducting thin films

    Energy Technology Data Exchange (ETDEWEB)

    Iida, Kazumasa [Nagoya University (Japan); IFW Dresden (Germany)

    2015-07-01

    It has been reported that Fe-based superconductors show high upper critical fields with low anisotropies at low temperatures. Hence these materials may offer a unique possibility for high field magnet applications. However, only a few reports on high-field transport properties of Co-doped Ba-122 and Fe(Se,Te) have been published and the only one for SmFeAs(O,F) thin films to date. In order to use this material class for applications, the knowledge of in-field and its orientation dependence of transport properties in a wide range of external fields need to be clarified. In this talk, I will report on high-field (up to dc 45 T) transport properties of P-doped Ba-122, SmFeAs(O,F) and NdFeAs(O,F) thin films prepared by MBE. Although P-doped Ba-122 has the lowest T{sub c}, self-field J{sub c} of over 6 MA/cm{sup 2} at 4.2 K is recorded, which is the highest value ever reported in Fe-based superconductors. Additionally, in-field performance of P-doped Ba-122 shows comparable to those of NdFeAs(O,F) and SmFeAs(O,F) for Hc. On the other hand, both NdFeAs(O,F) and SmFeAs(O,F) exhibited higher J{sub c} for H parallel ab due to the intrinsic pinning. These results indicate that P-doped Ba-122 is the most promising candidates for high-field magnet applications.

  3. The value of high-field MRI (3 T) in the assessment of sellar lesions

    Energy Technology Data Exchange (ETDEWEB)

    Pinker, K. [Department of Diagnostic Radiology, Medical University Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Ba-Ssalamah, A. [Department of Diagnostic Radiology, Medical University Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Wolfsberger, S. [Department of Neurosurgery, Medical University Vienna (Austria); Mlynarik, V. [Department of Diagnostic Radiology, Medical University Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Knosp, E. [Department of Neurosurgery, Medical University Vienna (Austria); Trattnig, S. [Department of Diagnostic Radiology, Medical University Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria)]. E-mail: siegfried.trattnig@univie.ac.at

    2005-06-01

    The aim of this study was the evaluation of the normal sellar anatomy in vitro and in vivo with high-field MRI and its application in the diagnosis of sellar pathologies in comparison to standard MRI. All high-field MR images were obtained using a 3 T Bruker Medspec 30/80 Scanner with a head birdcage transmit/receive coil and an actively shielded gradient system with a maximum gradient strength of 45 mT/m. Firstly an in vitro study of the sella turcica was performed to depict normal pituitary and sellar anatomy at high field. After a pilot-study this sequence-protocol was established: A RARE sequence (TR/TE = 7790/19 ms; matrix size, 512 x 512; RARE factor = 8, FOV, 200 mm) was used for T2-weighted coronal, axial and sagittal images. A 3D gradient echo sequence with magnetization-preparation (MP-RAGE, TR/TE/TI 33.5/7.6/800 ms, matrix size, 512 x 512; FOV, 200 mm, effective slice thickness, 1.88 mm; 3 averages) was used for acquisition of T1-weighted pre- and post-contrast images. Between January 2002 and March 200458 patients were enrolled in this study. Seven patients were examined for suspected microadenoma and in 51 patients 3T MRI was used to obtain additional information about the sellar lesion already known to be present from standard MRI. In 21 cases the accuracy of the imaging findings was assessed afterwards by comparison with intraoperative findings. The infiltration of the medial cavernous sinus wall was suspected on standard MRI on 15 sides (47%), on high-field MRI on 9 sides (28%) and could be verified by intraoperative findings on 6 sides (19%). Accordingly, sensitivity to infiltration was 83% for 3 T and 67% for standard MRI. Specificity was 84% for 3 T and 58% for standard MRI. Moreover, high-field MRI revealed microadenomas in 7 patients with a median diameter of 4 mm (range 2-9 mm). The segments of the cranial nerves were seen as mean 4 hypointense spots (range 2-5 spots) on high-field MRI in contrast to 3 spots (range 0-4 spots) on standard MRI

  4. The HEART score for chest pain patients

    NARCIS (Netherlands)

    Backus, B.E.

    2012-01-01

    The HEART score was developed to improve risk stratification in chest pain patients in the emergency department (ED). This thesis describes series of validation studies of the HEART score and sub studies for individual elements of the score. The predictive value of the HEART score for the occurrence

  5. When to Remove a Chest Tube.

    Science.gov (United States)

    Novoa, Nuria M; Jiménez, Marcelo F; Varela, Gonzalo

    2017-02-01

    Despite the increasing knowledge about the pleural physiology after lung resection, most practices around chest tube removal are dictated by personal preferences and experience. This article discusses recently published data on the topic and suggests opportunities for further investigation and future improvements.

  6. Chest pain in focal musculoskeletal disorders

    DEFF Research Database (Denmark)

    Stochkendahl, Mette Jensen; Christensen, Henrik Wulff

    2010-01-01

    overlapping conditions and syndromes of focal disorders, including Tietze syndrome, costochondritis, chest wall syndrome, muscle tenderness, slipping rib, cervical angina, and segmental dysfunction of the cervical and thoracic spine, have been reported to cause pain. For most of these syndromes, evidence...

  7. Treatment of 336 cases of chest trauma

    Directory of Open Access Journals (Sweden)

    ZHANG Jing

    2012-06-01

    Full Text Available 【Abstract】Objective: To summarize the clinical features, diagnosis and treatment of chest trauma. Methods: A retrospective analysis was conducted among 336 cases of chest trauma admitted to our hospital from January 2009 to May 2011. Results: Out of all cases, 325 were cured, accounting for 96.7%; 11 died, accounting for 3.3%. Among the dead cases, one died of hemorrhagic shock, three of acute respi-ratory distress syndrome, three of multiple organ failure, and four of severe multiple traumas. Conclusions: (1 For patients with severe chest trauma, early emergency treatment is crucial to save life. (2 Open thoracic surgery is needed for acute cardiac tamponade, intrapulmonary vascular injuries, progressive intrathoracic bleeding, lung laceration, tracheal breakage, and diaphrag-matic injury. In addition, operative timing and method should be well chosen. (3 Pulmonary contusion is one of common complications in chest trauma, for which the com-bination of strong anti-infection therapy and mechanical ventilation is an effective treatment strategy. Key words: Thoracic injuries; Thoracotomy; Emer-gency treatment

  8. VAC® for external fixation of flail chest

    DEFF Research Database (Denmark)

    Winge, Rikke; Berg, Jais O; Albret, Rikke

    2012-01-01

    A large aterior chest wall defect following tumor resection was reconstructed with a Gore-Tex® membrane and a combined musculocutaneous rectus femoris and tensor fasciae latae free flap. Subsequent paradoxical respiration impeded weaning from the ventilator. Appliance of Vacuum Assisted Closure...

  9. Treatment of 336 cases of chest trauma

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jing; CHU Xiang-yang; LIU Yi; WANG Yun-xi

    2012-01-01

    Objective: To summarize the clinical features,diagnosis and treatment of chest trauma.Methods: A retrospective analysis was conducted among 336 cases of chest trauma admitted to our hospital from January 2009 to May 2011.Results:Out of all cases,325 were cured,accounting for 96.7%; 11 died,accounting for 3.3%.Among the dead cases,one died of hemorrhagic shock,three of acute respiratory distress syndrome,three of multiple organ failure,and four of severe multiple traumas.Conclusions:(1) For patients with severe chest trauma,early emergency treatment is crucial to save life.(2) Open thoracic surgery is needed for acute cardiac tamponade,intrapulmonary vascular injuries,progressive intrathoracic bleeding,lung laceration,tracheal breakage,and diaphragmatic injury.In addition,operative timing and method should be well chosen.(3) Pulmonary contusion is one of common complications in chest trauma,for which the combination of strong anti-infection therapy and mechanical ventilation is an effective treatment strategy.

  10. The Funen Neck and Chest Pain study

    DEFF Research Database (Denmark)

    Fejer, René; Hartvigsen, Jan; Kyvik, Kirsten Ohm

    2006-01-01

    OBJECTIVE: To describe the Funen Neck and Chest Pain (FNCP) study and carry out a comprehensive non-response analysis of the quality of the survey. METHODS: The FNCP questionnaire was sent out to 7000 randomly selected individuals aged 20-71 years living in Funen County, Denmark. A full description...

  11. Chest radiography in the critically ill

    NARCIS (Netherlands)

    Kröner, A.

    2016-01-01

    Introduction: The chest radiograph (CXR) is a frequently obtained test to complement physical examination in ICU and post-surgery PACU patients. The opinion on indications for a CXR in these two patient categories varies worldwide. One approach is to obtain CXR on indication only, i.e., when there i

  12. Chest injury in victims of Bam earthquake

    Institute of Scientific and Technical Information of China (English)

    Seyed Mohammad Ghodsi; Moosa Zargar; Ali Khaji; Mojgan Karbakhsh

    2006-01-01

    Objective: To analyze the data of trauma patients with thoracic injury in the earthquake of Bam admitted to hospitals of Tehran University of Medical Science (TUMS)for better understanding the type and consequence of thoracic injuries in a major earthquake.Methods: After Bam earthquake registering 6.5 on the Richter scale, 526 trauma patients were admitted to hospitals of TUMS. Among them, 53 patients sustained thoracic injury.Results: This group was composed of 21 females (39.6%) and 32 males (60.4%). Fifteen patients (28.3%) had isolated chest injuries. Rib fracture (36.4%) was the most common injury in our patients and haemo/pneumothorax (25.5%) followed. Superficial injury was the most common accompanying injury. Multipletrauma patients with chest injury had higher injury severity score (ISS) versus patients with isolated chest injury (P =0.003).Conclusions: Chest wall injuries and haemo/pneumothorax comprise a considerable number of injuries in survival victims of earthquakes. Consequently, the majority of these patients can be treated with observation or tube thoracostomy. We should train and equip the health workers and members of rescue teams to treat and manage these patients in the field.

  13. ADX: a high field, high power density, Advanced Divertor test eXperiment

    Science.gov (United States)

    Vieira, R.; Labombard, B.; Marmar, E.; Irby, J.; Shiraiwa, S.; Terry, J.; Wallace, G.; Whyte, D. G.; Wolfe, S.; Wukitch, S.; ADX Team

    2014-10-01

    The MIT PSFC and collaborators are proposing an advanced divertor experiment (ADX) - a tokamak specifically designed to address critical gaps in the world fusion research program on the pathway to FNSF/DEMO. This high field (6.5 tesla, 1.5 MA), high power density (P/S ~ 1.5 MW/m2) facility would utilize Alcator magnet technology to test innovative divertor concepts for next-step DT fusion devices (FNSF, DEMO) at reactor-level boundary plasma pressures and parallel heat flux densities while producing high performance core plasma conditions. The experimental platform would also test advanced lower hybrid current drive (LHCD) and ion-cyclotron range of frequency (ICRF) actuators and wave physics at the plasma densities and magnetic field strengths of a DEMO, with the unique ability to deploy launcher structures both on the low-magnetic-field side and the high-field side - a location where energetic plasma-material interactions can be controlled and wave physics is most favorable for efficient current drive, heating and flow drive. This innovative experiment would perform plasma science and technology R&D necessary to inform the conceptual development and accelerate the readiness-for-deployment of FNSF/DEMO - in a timely manner, on a cost-effective research platform. Supported by DE-FC02-99ER54512.

  14. [Chest Wall Reconstruction Using Titanium Plates Sandwiched Between Sheets after Resection of Chest Wall Chondrosarcoma].

    Science.gov (United States)

    Endoh, Makoto; Oizumi, Hiroyuki; Kato, Hirohisa; Suzuki, Jun; Watarai, Hikaru; Hamada, Akira; Suzuki, Katsuyuki; Takahashi, Ai; Nakahashi, Kenta; Sugawara, Masato; Tsuchiya, Takashi; Sadahiro, Mitsuaki

    2016-07-01

    Extensive chest wall resection carries the risk of difficult reconstruction and surgical complications. We report our experience on chest wall reconstruction using titanium plates for a wide thoracic defect after tumor resection. A 74-year-old man was diagnosed with chondrosarcoma of the 6th rib on the right. He needed extensive chest wall resection because of skip lesions on 4th rib noted on operative inspection, leaving a defect measuring 33 × 20 cm. Reconstruction using 5 transverse titanium plates sandwiched between an expanded polytetrafluoroethylene patch and a polypropylene mesh sheet stabilized the chest wall. This reconstruction allowed successful separation from ventilatory support after operation. The postoperative course was uneventful, and he was discharged on postoperative day 20. The advantages of this form of reconstruction over conventional prostheses are rigidity, and stability and usability.

  15. 7.0T功能MR波谱动态定量检测视觉皮层代谢物对视觉刺激的反应%Investigation of the metabolic changes in visual cortex due to visual stimulation using high field magnetic resonance spectroscopy at 7.0 T

    Institute of Scientific and Technical Information of China (English)

    林艳; Morris Peter; 吴仁华

    2012-01-01

    investigate the metabolic changes in the visual cortex due to visual stimulation using high field functional proton magnetic resonance spectroscopy at 7.0 T.A clear picture of brain metabolism and neurotransmitter activity during activation was expected to be established.Methods Nine healthy subjects participated in this study. All MR measurements were acquired using a 7.0 T MR system and a 16-channel SENSE head coil. An initial fMRI scan was performed prior to spectroscopic acquisition in order to determine the activated region in the visual cortex.A cubic ROI of 2 cm× 2 cm × 2 cm was positioned inside the activated region for functional MRS acquisition.A short TE STEAM sequence was used for acquiring the MRS data. The functional paradigm comprised 6.6 min baseline followed by 13.2 min of visual stimulation and 19.8 min recovery.Summed averaged spectra for visual stimulus off and visual stimulus on were analyzed separately using LC Model and internal reference of water. A Wilcoxon signed rank test was conducted to compare the metabolite changes. Results During stimulation,concentration in Asp [ ( 3.20 ± 0.28 ) μmol/g ],Gln [ ( 2.07 ± 0.10 ) μmol/g ] and Gly [ ( 1.65 ± 0.11 )μmol/g ] was found to be significantly decreased,compared with that of ( 3.52 ± 0.28 ),( 2.25 ± 0.10 ) and ( 1.85 ± 0.11 ) μmol/g in rest ( Z =- 2.073,- 2.073 and - 2.429,respectively,P < 0.05 ).The level in Glu [ ( 11.50 ± 0.11 ) μmol/g],GSH[ (2.45 ± 0.10) μmol/g] and Lac[ (0.89 ± 0.05) μ.mol/g]due to neuronal activation was found to be significantly increased,versus resting concentration of ( 11.28 ± 0.11 ),( 2.28 ± 0.10 ) and (0.79 ± 0.05 ) μmol/g,respectively ( Z =2.521,2.310,2.016,respectively,P <0.05).Glc level [ (1.54 ± 0.23 )μmol/g] exhibited a tendency to decrease throughout the period of stimulation,compared with that of [ (1.78 ± 0.28 ) μmol/g ] in rest,but the decrease did not reach statistical significance (Z =- 1.897,P > 0.05 ).Conclusions Using a novel visual

  16. Quick identification of acute chest pain patients study (QICS)

    NARCIS (Netherlands)

    Willemsen, Hendrik M.; de Jong, Gonda; Tio, Rene A.; Nieuwland, Wybe; Kema, Ido P.; van der Horst, Iwan C. C.; Oudkerk, Mattijs; Zijlstra, Felix

    2009-01-01

    Background: Patients with acute chest pain are often referred to the emergency ward and extensively investigated. Investigations are costly and could induce unnecessary complications, especially with invasive diagnostics. Nevertheless, chest pain patients have high mortalities. Fast identification o

  17. CNE article: pain after lung transplant: high-frequency chest wall oscillation vs chest physiotherapy.

    Science.gov (United States)

    Esguerra-Gonzalez, Angeli; Ilagan-Honorio, Monina; Fraschilla, Stephanie; Kehoe, Priscilla; Lee, Ai Jin; Marcarian, Taline; Mayol-Ngo, Kristina; Miller, Pamela S; Onga, Jay; Rodman, Betty; Ross, David; Sommer, Susan; Takayanagi, Sumiko; Toyama, Joy; Villamor, Filma; Weigt, S Samuel; Gawlinski, Anna

    2013-03-01

    Background Chest physiotherapy and high-frequency chest wall oscillation (HFCWO) are routinely used after lung transplant to facilitate removal of secretions. To date, no studies have been done to investigate which therapy is more comfortable and preferred by lung transplant recipients. Patients who have less pain may mobilize secretions, heal, and recover faster. Objectives To compare effects of HFCWO versus chest physiotherapy on pain and preference in lung transplant recipients. Methods In a 2-group experimental, repeated-measures design, 45 lung transplant recipients (27 single lung, 18 bilateral) were randomized to chest physiotherapy (10 AM, 2 PM) followed by HFCWO (6 PM, 10 PM; group 1, n=22) or vice versa (group 2, n=23) on postoperative day 3. A verbal numeric rating scale was used to measure pain before and after treatment. At the end of the treatment sequence, a 4-item patient survey was administered to assess treatment preference, pain, and effectiveness. Data were analyzed with χ(2) and t tests and repeated-measures analysis of variance. Results A significant interaction was found between mean difference in pain scores from before to after treatment and treatment method; pain scores decreased more when HFCWO was done at 10 AM and 6 PM (P =.04). Bilateral transplant recipients showed a significant preference for HFCWO over chest physiotherapy (11 [85%] vs 2 [15%], P=.01). However, single lung recipients showed no significant difference in preference between the 2 treatments (11 [42%] vs 14 [54%]). Conclusions HFCWO seems to provide greater decreases in pain scores than does chest physiotherapy. Bilateral lung transplant recipients preferred HFCWO to chest physiotherapy. HFCWO may be an effective, feasible alternative to chest physiotherapy. (American Journal of Critical Care. 2013;22:115-125).

  18. Observation of Thermoelectric Currents in High-Field Superconductor-Ferromagnet Tunnel Junctions.

    Science.gov (United States)

    Kolenda, S; Wolf, M J; Beckmann, D

    2016-03-01

    We report on the experimental observation of spin-dependent thermoelectric currents in superconductor-ferromagnet tunnel junctions in high magnetic fields. The thermoelectric signals are due to a spin-dependent lifting of the particle-hole symmetry, and are found to be in excellent agreement with recent theoretical predictions. The maximum Seebeck coefficient inferred from the data is about -100  μV/K, much larger than commonly found in metallic structures. Our results directly prove the coupling of spin and heat transport in high-field superconductors.

  19. High Field Seeking State Atom Laser and Properties of Flux

    Institute of Scientific and Technical Information of China (English)

    XIA Lin; XIONG Wei; YANG Fan; YI Lin; ZHOU Xiao-Ji; CHEN Xu-Zong

    2008-01-01

    We present an experimental study on the continuous atom laser. The experiments show that a high field seeking state atom laser with stable flux can be formed by increasing the strength of outcoupling before large density fluctuations appear. It is easy to obtain a long length or high speed output with this kind of atom laser.

  20. 20 CFR 718.102 - Chest roentgenograms (X-rays).

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Chest roentgenograms (X-rays). 718.102... roentgenograms (X-rays). (a) A chest roentgenogram (X-ray) shall be of suitable quality for proper classification...-rays as described in Appendix A. (b) A chest X-ray to establish the existence of pneumoconiosis...

  1. 46 CFR 194.10-20 - Magazine chest construction.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Magazine chest construction. 194.10-20 Section 194.10-20... construction. (a) Magazine chests shall be of watertight metal construction with flush interior. The body and...) Chests shall be secured to the vessel's structure by means of permanently installed foundation clips...

  2. Chest radiographic manifestations of scrub typhus

    Directory of Open Access Journals (Sweden)

    KPP Abhilash

    2016-01-01

    Full Text Available Background and Rationale: Respiratory system involvement in scrub typhus is seen in 20–72% of patients. In endemic areas, good understanding and familiarity with the various radiologic findings of scrub typhus are essential in identifying pulmonary complications. Materials and Methods: Patients admitted to a tertiary care center with scrub typhus between October 2012 and September 2013 and had a chest X ray done were included in the analysis. Details and radiographic findings were noted and factors associated with abnormal X-rays were analyzed. Results: The study cohort contained 398 patients. Common presenting complaints included fever (100%, generalized myalgia (83%, headache (65%, dyspnea (54%, cough (24.3%, and altered sensorium (14%. Almost half of the patients (49.4% had normal chest radiographs. Common radiological pulmonary abnormalities included pleural effusion (14.6%, acute respiratory distress syndrome (14%, airspace opacity (10.5%, reticulonodular opacities (10.3%, peribronchial thickening (5.8%, and pulmonary edema (2%. Cardiomegaly was noted in 3.5% of patients. Breathlessness, presence of an eschar, platelet counts of 2 mg/dL had the highest odds of having an abnormal chest radiograph. Patients with an abnormal chest X-ray had a higher requirement of noninvasive ventilation (odds ratio [OR]: 13.98; 95% confidence interval CI: 5.89–33.16, invasive ventilation (OR: 18.07; 95% CI: 6.42–50.88, inotropes (OR: 8.76; 95% CI: 4.35–17.62, higher involvement of other organ systems, longer duration of hospital stay (3.18 ± 3 vs. 7.27 ± 5.58 days; P< 0.001, and higher mortality (OR: 4.63; 95% CI: 1.54–13.85. Conclusion: Almost half of the patients with scrub typhus have abnormal chest radiographs. Chest radiography should be included as part of basic evaluation at presentation in patients with scrub typhus, especially in those with breathlessness, eschar, jaundice, and severe thrombocytopenia.

  3. CPDX (Chest Pain Diagnostic Program) - A Decision Support System for the Management of Acute Chest Pain (User’s Manual)

    Science.gov (United States)

    1988-02-25

    feu hours) when he has teen free of pain since the present episode started, this is intermittent. Otherwise assess as continuous. Beware the patient...assumed that crewmembers with chest pain have a physical etiology for chest pain. Disorders that present with epigastric pain such as gastritis , peptic...be assumed that crewmembers with chest pain have a physical etiology for chest pain. Disorders that present with epigastric pain such as gastritis

  4. MAGNET

    CERN Multimedia

    by B. Curé

    2011-01-01

    The magnet operation was very satisfactory till the technical stop at the end of the year 2010. The field was ramped down on 5th December 2010, following the successful regeneration test of the turbine filters at full field on 3rd December 2010. This will limit in the future the quantity of magnet cycles, as it is no longer necessary to ramp down the magnet for this type of intervention. This is made possible by the use of the spare liquid Helium volume to cool the magnet while turbines 1 and 2 are stopped, leaving only the third turbine in operation. This obviously requires full availability of the operators to supervise the operation, as it is not automated. The cryogenics was stopped on 6th December 2010 and the magnet was left without cooling until 18th January 2011, when the cryoplant operation resumed. The magnet temperature reached 93 K. The maintenance of the vacuum pumping was done immediately after the magnet stop, when the magnet was still at very low temperature. Only the vacuum pumping of the ma...

  5. Hyperfine coupling constant for {sup 59}Co estimated from a high-field susceptibility and high-field NMR shift in ferromagnetic Co{sub 2}TiGa and Co{sub 2}VGa

    Energy Technology Data Exchange (ETDEWEB)

    Nishihara, H; Furutani, Y; Wada, T [Faculty of Science and Technology, Ryukoku University, Otsu 520-2194 (Japan); Kanomata, T [Faculty of Engineering, Tohoku Gakuin University, Tagajo 985-8537 (Japan); Kobayashi, K; Ishida, K [Graduate School of Engineering, Tohoku University, Sendai 980-8579 (Japan); Kainuma, R [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Sendai 980-8577 (Japan); Koyama, K; Watanabe, K, E-mail: nishihara@rins.ryukoku.ac.j [Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan)

    2010-01-01

    The hyperfine coupling constant for {sup 59}Co in the ferromagnetic state of a Heusler alloy Co{sub 2}TiGa in the high-field range has been estimated to be 170 kOe per 1 {mu}{sub B} of the moment of cobalt atom from the high-field magnetic susceptibility of 2.3 x 10{sup -6} emu/gOe measured at 5 K in a field range from 20 to 70 kOe and a reported positive high-field NMR shift of +0.83 percent. The value of the hyperfine coupling constant has been found to be even larger in the case of Co{sub 2}VGa. These features suggest that the positive hyperfine field at Co nucleus in the Co-based Heusler alloys is due to conduction electron polarization rather than a transferred hyperfine field.

  6. Chest radiographic findings in acute paraquat poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Na, Gyeong Gyun; Lee, Mi Sook; Kim, Hee Jun; Sun, In O [Presbyterian Medical Center, Jeonju (Korea, Republic of)

    2016-01-15

    To describe the chest radiographic findings of acute paraquat poisoning. 691 patients visited the emergency department of our hospital between January 2006 and October 2012 for paraquat poisoning. Of these 691, we identified 56 patients whose initial chest radiographs were normal but who developed radiographic abnormalities within one week. We evaluated their radiographic findings and the differences in imaging features based on mortality. The most common finding was diffuse consolidation (29/56, 52%), followed by consolidation with linear and nodular opacities (18/56, 32%), and combined consolidation and pneumomediastinum (7/56, 13%). Pleural effusion was noted in 17 patients (30%). The two survivors (4%) showed peripheral consolidations, while the 54 patients (96%) who died demonstrated bilateral (42/54, 78%) or unilateral (12/54, 22%) diffuse consolidations. Rapidly progressing diffuse pulmonary consolidation was observed within one week on follow-up radiographs after paraquat ingestion in the deceased, but the survivors demonstrated peripheral consolidation.

  7. Injuries of the chestFNx01

    Directory of Open Access Journals (Sweden)

    Deodhar S

    1979-01-01

    Full Text Available Thirty cases of chest injuries were admitted in the Department of Surgery, K.E.M. Hospital, Bombay. These injuries seem to be fairly common. Detailed examination at the time of admission is necessary to assess the clinical presentation and the presence of major complications. Institution of intra-peritoneal drainage, restoration of negative intra-pleural pressure and active respiratory physiotherapy constitute an important part of the treatment. The literature on this subject is briefly reviewed

  8. Chest pain associated with moderator band pacing.

    Science.gov (United States)

    Goli, Anil K; Kaszala, Karoly; Osman, Mohammed N; Lucke, John; Carrillo, Roger

    2014-10-01

    A 65-year-old man was evaluated for chronic chest pain that had been present for 8 years after placement of a dual-chamber implantable cardioverter-defibrillator to treat inducible ventricular tachycardia. Previous coronary angiography had revealed nonobstructive coronary artery disease and a left ventricular ejection fraction of 0.45 to 0.50, consistent with mild idiopathic nonischemic cardiomyopathy. Evaluation with chest radiography and transthoracic echocardiography showed the implantable cardioverter-defibrillator lead to be embedded within the right ventricle at the moderator band, which had mild calcification. Treatment included extraction of the dual-coil lead and placement of a new single-coil right ventricular lead at the mid septum. The patient had complete relief of symptoms after the procedure. This case shows that chest pain can be associated with the placement of a right ventricular implantable cardioverter-defibrillator lead in the moderator band and that symptomatic relief can occur after percutaneous lead extraction and the implantation of a new right ventricular lead to the mid septal region.

  9. VAC® for external fixation of flail chest

    Directory of Open Access Journals (Sweden)

    Rikke Winge

    2012-06-01

    Full Text Available A large anterior chest wall defect following tumor resection was reconstructed with a Gore- Tex® membrane and a combined musculocutaneous rectus femoris and tensor fasciae latae free flap. Subsequent paradoxical respiration impeded weaning from the ventilator. Appliance of Vacuum Assisted Closure® (VAC® resulted in immediate chest wall stability and a decrease in the patient’s need for respiratory support. Shortly thereafter, the VAC® was discontinued and the patient was discharged from the intensive care unit (ICU. This case report is the first to describe the successful use of VAC® as an adjuvant to a one-stage procedure for large thoracic wall reconstruction, allowing sufficient temporary external fixation to eliminate paradoxical respiration and plausibly shorten the stay in the ICU. No adverse effects on flap healing or haemodynamics were recorded. It is likely that external VAC® can improve thoracic stability and pulmonary function in a patient with flail chest and decrease the need for mechanical ventilation.

  10. Low-field MRI can be more sensitive than high-field MRI

    Science.gov (United States)

    Coffey, Aaron M.; Truong, Milton L.; Chekmenev, Eduard Y.

    2013-12-01

    MRI signal-to-noise ratio (SNR) is the key factor for image quality. Conventionally, SNR is proportional to nuclear spin polarization, which scales linearly with magnetic field strength. Yet ever-stronger magnets present numerous technical and financial limitations. Low-field MRI can mitigate these constraints with equivalent SNR from non-equilibrium ‘hyperpolarization' schemes, which increase polarization by orders of magnitude independently of the magnetic field. Here, theory and experimental validation demonstrate that combination of field independent polarization (e.g. hyperpolarization) with frequency optimized MRI detection coils (i.e. multi-turn coils using the maximum allowed conductor length) results in low-field MRI sensitivity approaching and even rivaling that of high-field MRI. Four read-out frequencies were tested using samples with identical numbers of 1H and 13C spins. Experimental SNRs at 0.0475 T were ∼40% of those obtained at 4.7 T. Conservatively, theoretical SNRs at 0.0475 T 1.13-fold higher than those at 4.7 T were possible despite an ∼100-fold lower detection frequency, indicating feasibility of high-sensitivity MRI without technically challenging, expensive high-field magnets. The data at 4.7 T and 0.0475 T was obtained from different spectrometers with different RF probes. The SNR comparison between the two field strengths accounted for many differences in parameters such as system noise figures and variations in the probe detection coils including Q factors and coil diameters.

  11. High field MREIT: setup and tissue phantom imaging at 11 T

    Science.gov (United States)

    Sadleir, Rosalind; Grant, Samuel; Zhang, Sung Uk; Oh, Suk Hoon; Lee, Byung Il; Woo, Eung Je

    2008-01-01

    Magnetic resonance electrical impedance tomography (MREIT) has the potential to provide conductivity and current density images with high spatial resolution and accuracy. Recent experimental studies at a field strength of 3 T showed that the spatial resolution of conductivity and current density images may be similar to that of conventional MR images as long as enough current is injected, at least 20 mA when the object being imaged has a size similar to the human head. To apply the MREIT technique to image small conductivity changes using less injection current, we performed MREIT studies at 11 T field strength, where noise levels in measured magnetic flux density data are significantly lower. In this paper we present the experimental results of imaging biological tissues with different conductivity values using MREIT at 11 T. We describe technical difficulties encountered in using high-field MREIT systems and possible solutions. High-field MREIT is suggested as a research tool for obtaining accurate conductivity data from tissue samples and animal subjects. PMID:16636417

  12. Development of high-pressure, high-field and multifrequency electron spin resonance system.

    Science.gov (United States)

    Sakurai, T; Taketani, A; Tomita, T; Okubo, S; Ohta, H; Uwatoko, Y

    2007-06-01

    The electron spin resonance (ESR) system which covers the magnetic field region up to 16 T, the quasicontinuous frequency region from 60 to 700 GHz, the temperature region from 1.8 to 4.2 K, and the hydrostatic pressure region up to 1.1 GPa has been developed. This is the first pulsed high-field and multifrequency ESR system with the pressure region over 1 GPa as far as we know. Transmission ESR spectra under hydrostatic pressure can be obtained by combining a piston-cylinder-type pressure cell and the pulsed magnetic field ESR apparatus. The pressure cell consists of a NiCrAl cylinder and sapphire or zirconia inner parts. The use of sapphire or zirconia as inner parts enables us to observe ESR under pressure because these inner parts have high transmittance for the electromagnetic wave with millimeter and submillimeter wavelengths. We have successfully applied this system for the pressure dependence measurements of an isolated spin system NiSnCl(6)6H(2)O up to 1.1 GPa. It was found that the single ion anisotropy parameter D of this compound strongly depends on pressure. The parameter D is approximately proportional to the pressure up to 0.75 GPa, and the relation between D and the pressure can be used for the pressure calibration of this high-field and high-pressure ESR system.

  13. Hole-exciton interaction induced high field decay of magneto-electroluminescence in Alq{sub 3}-based organic light-emitting diodes at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Tingting; Holford, D. F.; Gu, Hang; Kreouzis, T. [Materials Research Institute and School of Physics and Astronomy, Queen Mary University of London, Mile End Road, London E1 4NS (United Kingdom); Zhang, Sijie, E-mail: Sijie.zhang@scu.edu.cn, E-mail: w.gillin@qmul.ac.uk [College of Physical Science and Technology, Sichuan University, Chengdu 610064 (China); Gillin, W. P., E-mail: Sijie.zhang@scu.edu.cn, E-mail: w.gillin@qmul.ac.uk [Materials Research Institute and School of Physics and Astronomy, Queen Mary University of London, Mile End Road, London E1 4NS (United Kingdom); College of Physical Science and Technology, Sichuan University, Chengdu 610064 (China)

    2016-01-11

    The magnetic field effects on the electroluminescence of aluminium tris-(8-hydroxyqinoline) (Alq{sub 3}) based organic light emitting diodes have been investigated by varying the electron/hole ratio in the emissive layer. Experimental results reveal that a negative high field effect in the magneto-electroluminescence (MEL) can be found in devices with very low triplet exciton concentration at room temperature. This suggests triplet-triplet annihilation cannot be used to explain the negative high field MEL in the Alq{sub 3} system. Our results suggest that hole-exciton interaction may be the origin of the negative high field MEL and also, in parallel with this interaction, there is also the more common positive high field process occurring which has been tentatively attributed to electron-exciton interactions. The competition between these different processes decides the final shape of the MEL at high fields.

  14. High field optical nonlinearity and the Kramers-Kronig relations.

    Science.gov (United States)

    Wahlstrand, J K; Cheng, Y-H; Milchberg, H M

    2012-09-14

    The nonlinear optical response to high fields is absolutely measured for the noble gas atoms He, Ne, Ar, Kr, and Xe. We find that the response is quadratic in the laser field magnitude up to the ionization threshold of each gas. Its size and quadratic dependence are well predicted by a Kramers-Kronig analysis employing known ionization probabilities, and the results are consistent with calculations using the time-dependent Schrödinger equation.

  15. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      Following the unexpected magnet stops last August due to sequences of unfortunate events on the services and cryogenics [see CMS internal report], a few more events and initiatives again disrupted the magnet operation. All the magnet parameters stayed at their nominal values during this period without any fault or alarm on the magnet control and safety systems. The magnet was stopped for the September technical stop to allow interventions in the experimental cavern on the detector services. On 1 October, to prepare the transfer of the liquid nitrogen tank on its new location, several control cables had to be removed. One cable was cut mistakenly, causing a digital input card to switch off, resulting in a cold-box (CB) stop. This tank is used for the pre-cooling of the magnet from room temperature down to 80 K, and for this reason it is controlled through the cryogenics control system. Since the connection of the CB was only allowed for a field below 2 T to avoid the risk of triggering a fast d...

  16. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    Operation of the magnet has gone quite smoothly during the first half of this year. The magnet has been at 4.5K for the full period since January. There was an unplanned short stop due to the CERN-wide power outage on May 28th, which caused a slow dump of the magnet. Since this occurred just before a planned technical stop of the LHC, during which access in the experimental cavern was authorized, it was decided to leave the magnet OFF until 2nd June, when magnet was ramped up again to 3.8T. The magnet system experienced a fault also resulting in a slow dump on April 14th. This was triggered by a thermostat on a filter choke in the 20kA DC power converter. The threshold of this thermostat is 65°C. However, no variation in the water-cooling flow rate or temperature was observed. Vibration may have been the root cause of the fault. All the thermostats have been checked, together with the cables, connectors and the read out card. The tightening of the inductance fixations has also been checked. More tem...

  17. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      The magnet was energised at the beginning of March 2012 at a low current to check all the MSS safety chains. Then the magnet was ramped up to 3.8 T on 6 March 2012. Unfortunately two days later an unintentional switch OFF of the power converter caused a slow dump. This was due to a misunderstanding of the CCC (CERN Control Centre) concerning the procedure to apply for the CMS converter control according to the beam-mode status at that time. Following this event, the third one since 2009, a discussion was initiated to define possible improvement, not only on software and procedures in the CCC, but also to evaluate the possibility to upgrade the CMS hardware to prevent such discharge from occurring because of incorrect procedure implementations. The magnet operation itself was smooth, and no power cuts took place. As a result, the number of magnetic cycles was reduced to the minimum, with only two full magnetic cycles from 0 T to 3.8 T. Nevertheless the magnet suffered four stops of the cryogeni...

  18. Cross-sectional imaging with CT and/or MRI of pediatric chest tumors

    Energy Technology Data Exchange (ETDEWEB)

    Wyttenbach, R.; Vock, P.; Tschaeppeler, H. [Department of Diagnostic Radiology, Division of Children`s Radiology, University Hospital, Bern (Switzerland)

    1998-07-01

    The purpose of this study was to provide an overview of the spectrum of pediatric chest masses, to present the results of cross-sectional imaging with CT and/or MRI, and to define diagnostic criteria to limit differential diagnosis. Seventy-eight children with thoracic mass lesions were retrospectively evaluated using CT (72 patients) and/or MR imaging (12 patients). All masses were evaluated for tissue characteristics (attenuation values or signal intensity, enhancement, and calcification) and were differentiated according to age, gender, location, and etiology. Twenty-eight of 38 (74 %) mediastinal masses were malignant (neuroblastoma, malignant lymphoma). Thirty of 38 (79 %) pulmonary masses were metastatic in origin, all with an already known primary tumor (osteosarcoma, Wilms tumor). With one exception, all remaining pulmonary lesions were benign. Seventeen of 21 (81 %) chest wall lesions were malignant (Ewing sarcoma, primitive neuroectodermal tumor). The majority of mediastinal and chest wall tumors in children is malignant. Lung lesions are usually benign, unless a known extrapulmonary tumor suggests pulmonary metastases. Cross-sectional imaging with CT and/or MRI allows narrowing of the differential diagnosis of pediatric chest masses substantially by defining the origin and tissue characteristics. Magnetic resonance imaging is preferred for posterior mediastinal lesions, whereas CT should be used for pulmonary lesions. For the residual locations both modalities are complementary. (orig.) With 5 figs., 3 tabs., 20 refs.

  19. High-field paramagnetic Meissner effect and flux creep in low-T c Ti-V alloy superconductors

    Science.gov (United States)

    Matin, M.; Chattopadhyay, M. K.; Sharath Chandra, L. S.; Roy, S. B.

    2016-02-01

    We report an experimental study on the high-field paramagnetic Meissner effect (HFPME) performed by measuring both the temperature and time dependence of magnetization in the two compositions of superconducting Ti-V alloys where certain secondary phases are non-superconducting, and thereby act as efficient pinning centres for the flux lines. While spatially non-uniform flux density driven by flux line pinning at these secondary phases is the necessary condition for the observation of the HFPME, our study indicates that the flux creep effect plays a supplementary role to reinforce the HFPME. It is found that in the temperature and magnetic field regime of the HFPME, the field-cooled magnetization of these samples relaxes monotonically towards a more positive value with elapsed time. We comment on how this paramagnetic relaxation behaviour of the field-cooled magnetization is correlated with the unusual thermo-magnetic responses related to the HFPME.

  20. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    The magnet was successfully operated at the end of the year 2009 despite some technical problems on the cryogenics. The magnet was ramped up to 3.8 T at the end of November until December 16th when the shutdown started. The magnet operation met a few unexpected stops. The field was reduced to 3.5 T for about 5 hours on December 3rd due to a faulty pressure sensor on the helium compressor. The following day the CERN CCC stopped unintentionally the power converters of the LHC and the experiments, triggering a ramp down that was stopped at 2.7 T. The magnet was back at 3.8 T about 6 hours after CCC sent the CERN-wide command. Three days later, a slow dump was triggered due to a stop of the pump feeding the power converter water-cooling circuit, during an intervention on the water-cooling plant done after several disturbances on the electrical distribution network. The magnet was back at 3.8 T in the evening the same day. On December 10th a break occurred in one turbine of the cold box producing the liquid ...

  1. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      The magnet and its sub-systems were stopped at the beginning of the winter shutdown on 8th December 2011. The magnet was left without cooling during the cryogenics maintenance until 17th January 2012, when the cryoplant operation resumed. The magnet temperature reached 93 K. The vacuum pumping was maintained during this period. During this shutdown, the yearly maintenance was performed on the cryogenics, the vacuum pumps, the magnet control and safety systems, and the power converter and discharge lines. Several preventive actions led to the replacement of the electrovalve command coils, and the 20A DC power supplies of the magnet control system. The filters were cleaned on the demineralised water circuits. The oil of the diffusion pumps was changed. On the cryogenics, warm nitrogen at 343 K was circulated in the cold box to regenerate the filters and the heat exchangers. The coalescing filters have been replaced at the inlet of both the turbines and the lubricant trapping unit. The active cha...

  2. MAGNET

    CERN Multimedia

    B. Curé

    2013-01-01

      The magnet was operated without any problem until the end of the LHC run in February 2013, apart from a CERN-wide power glitch on 10 January 2013 that affected the CMS refrigerator, causing a ramp down to 2 T in order to reconnect the coldbox. Another CERN-wide power glitch on 15 January 2013 didn’t affect the magnet subsystems, the cryoplant or the power converter. At the end of the magnet run, the reconnection of the coldbox at 2.5 T was tested. The process will be updated, in particular the parameters of some PID valve controllers. The helium flow of the current leads was reduced but only for a few seconds. The exercise will be repeated with the revised parameters to validate the automatic reconnection process of the coldbox. During LS1, the water-cooling services will be reduced and many interventions are planned on the electrical services. Therefore, the magnet cryogenics and subsystems will be stopped for several months, and the magnet cannot be kept cold. In order to avoid unc...

  3. MAGNET

    CERN Multimedia

    B. Curé

    2011-01-01

    The CMS magnet has been running steadily and smoothly since the summer, with no detected flaw. The magnet instrumentation is entirely operational and all the parameters are at their nominal values. Three power cuts on the electrical network affected the magnet run in the past five months, with no impact on the data-taking as the accelerator was also affected at the same time. On 22nd June, a thunderstorm caused a power glitch on the service electrical network. The primary water cooling at Point 5 was stopped. Despite a quick restart of the water cooling, the inlet temperature of the demineralised water on the busbar cooling circuit increased by 5 °C, up to 23.3 °C. It was kept below the threshold of 27 °C by switching off other cooling circuits to avoid the trigger of a slow dump of the magnet. The cold box of the cryogenics also stopped. Part of the spare liquid helium volume was used to maintain the cooling of the magnet at 4.5 K. The operators of the cryogenics quickly restarted ...

  4. Numerical evaluation of E-fields induced by body motion near high-field MRI scanner.

    Science.gov (United States)

    Crozier, S; Liu, F

    2004-01-01

    In modern magnetic resonance imaging (MRI), both patients and radiologists are exposed to strong, nonuniform static magnetic fields inside or outside of the scanner, in which the body movement may be able to induce electric currents in tissues which could be possibly harmful. This paper presents theoretical investigations into the spatial distribution of induced E-fields in the human model when moving at various positions around the magnet. The numerical calculations are based on an efficient, quasistatic, finite-difference scheme and an anatomically realistic, full-body, male model. 3D field profiles from an actively-shielded 4 T magnet system are used and the body model projected through the field profile with normalized velocity. The simulation shows that it is possible to induce E-fields/currents near the level of physiological significance under some circumstances and provides insight into the spatial characteristics of the induced fields. The results are easy to extrapolate to very high field strengths for the safety evaluation at a variety of field strengths and motion velocities.

  5. Demountable, High field High-Temperature Superconductor TF coils for flexible steady-state fusion experiments

    Science.gov (United States)

    Michael, Phillip; Bromberg, Leslie; Vieira, Rui; Minervini, Joseph; Galea, Christopher; Hensley, Sarah; Whyte, Dennis

    2014-10-01

    The excellent properties of HTS materials (e.g., YBCO) at high fields and elevated temperatures (>20 K), offer operational advantages for fusion machines, but results in challenges. For fusion devices, the ability to disassemble the TF coil is very attractive as it provides direct access to maintain the vacuum vessel, first wall and other components in a timely manner. High current conductors, made from multiple thin tapes, are not available but are being developed. Quench protection is a serious issue with HTS magnets, and novel means are needed to detect normal zones and to quickly discharge the magnet. Potential cables designs, demountable magnets and solutions to quench and protection issues for an HTS TF magnet for the Vulcan device (long term PMI studies) will be described. We also describe means for making continuous, persistent loops with HTS tapes. These loops offer an alternative to expensive monoliths for field control for complex geometries, such as stellarator-like fields. Partially supported by US DOE DE-FC02-93ER54186.

  6. MAGNETS

    Science.gov (United States)

    Hofacker, H.B.

    1958-09-23

    This patent relates to nmgnets used in a calutron and more particularly to means fur clamping an assembly of magnet coils and coil spacers into tightly assembled relation in a fluid-tight vessel. The magnet comprises windings made up of an assembly of alternate pan-cake type coils and spacers disposed in a fluid-tight vessel. At one end of the tank a plurality of clamping strips are held firmly against the assembly by adjustable bolts extending through the adjacent wall. The foregoing arrangement permits taking up any looseness which may develop in the assembly of coils and spacers.

  7. [Isolated chest trauma in elderly patients].

    Science.gov (United States)

    Yersin, Bertrand; Carron, Pierre-Nicolas; Pasquier, Mathieu; Zingg, Tobias

    2015-08-12

    In elderly patients, a blunt trauma of the chest is associated with a significant risk of complications and mortality. The number of ribs fractures (≥ 4), the presence of bilateral rib fractures, of a pulmonary contusion, of existent comorbidities or acute extra-thoracic traumatic lesions, and lastly the severity of thoracic pain, are indeed important risk factors of complications and mortality. Their presence may require hospitalization of the patient. When complications do occur, they are represented by alveolar hypoventilation, pulmonary atelectasia and broncho-pulmonary infections. When hospitalization is required, it may allow for the specific treatment of thoracic pain, including locoregional anesthesia techniques.

  8. Pitfalls and variants in pediatric chest imaging.

    Science.gov (United States)

    García Asensio, D; Fernández Martín, M

    2016-05-01

    Most pitfalls in the interpretation of pediatric chest imaging are closely related with the technique used and the characteristics of pediatric patients. To obtain a quality image that will enable the correct diagnosis, it is very important to use an appropriate technique. It is important to know how technical factors influence the image and to be aware of the possible artifacts that can result from poor patient cooperation. Moreover, radiologists need to be familiar with the normal anatomy in children, with the classic radiologic findings, and with the anatomic and developmental variants to avoid misinterpreting normal findings as pathological.

  9. Atrioventricular Dissociation following Blunt Chest Trauma

    Directory of Open Access Journals (Sweden)

    Salim Surani

    2014-01-01

    Full Text Available Blunt chest trauma (BCT is a common clinical presentation seen in emergency departments. Few cases of cardiac conduction abnormalities due to BCT have been reported in the medical literature. This dysrhythmias may present as permanent conduction defects requiring permanent pacemaker or may have temporary conduction abnormalities requiring temporary pacemaker or supportive care. We present the case of a young woman who suffered from BCT after being kicked by a horse with the development of a significant substernal hematoma. She developed temporary atrioventricular block, which was completely resolved with the decrease in the size of the substernal hematoma suffered.

  10. MAGNET

    CERN Multimedia

    B. Curé

    2011-01-01

    The magnet ran smoothly in the last few months until a fast dump occurred on 9th May 2011. Fortunately, this occurred in the afternoon of the first day of the technical stop. The fast dump was due to a valve position controller that caused the sudden closure of a valve. This valve is used to regulate the helium flow on one of the two current leads, which electrically connects the coil at 4.5 K to the busbars at room temperature. With no helium flow on the lead, the voltage drop and the temperatures across the leads increase up to the defined thresholds, triggering a fast dump through the Magnet Safety System (MSS). The automatic reaction triggered by the MSS worked properly. The helium release was limited as the pressure rise was just at the limit of the safety valve opening pressure. The average temperature of the magnet reached 72 K. It took four days to recover the temperature and refill the helium volumes. The faulty valve controller was replaced by a spare one before the magnet ramp-up resumed....

  11. Bacteriological research for the contamination of equipment in chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seung Gu; Song, Woon Heung; Kweon, Dae Cheol [Shinhan University, Uijeongbu (Korea, Republic of)

    2015-12-15

    The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections.

  12. Lung Morphological Changes in Closed Chest Injury (an experimental study

    Directory of Open Access Journals (Sweden)

    A. M. Golubev

    2012-01-01

    Full Text Available Objective: to study lung morphological changes in a closed chest injury model in laboratory animals. Material and methods. Experiments were carried out in 30 male albino nonbred rats weighing 350—380 g. Closed chest injury was simulated, by exposing the chest of anesthetized rats to a 300-g metal cylinder falling from a height of 30 cm. The observation periods were 1, 3, 6, and 24 hours. Results. The signs of evident perivenular edema that was uncharas-teristic to acute respiratory distress syndrome induced by other causes are an important peculiarity of lung morphological changes in this experimental model of closed chest injury. Conclusion. The experimental studies clarified the pattern of lung morphological changes in the early period after closed chest injury. Key words: closed chest injury, pulmonary edema.

  13. Scope and limitations of sonography of the chest during childhood

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, K.; Mayr, B.; Fendel, H.

    1986-05-01

    The advantages and limitations of the sonographic examination of the chest in 16 children are described. Partial opacification of the chest has been found in nine, a total 'white' hemithorax in 7 children. Sonographic guided taps of the chest were performed in 3 children. Necessity, extent and yield of additional radiological examinations, especially computed tomography of the thorax, are discussed in detail.

  14. Chest physiotherapy in children with acute bacterial pneumonia

    OpenAIRE

    2015-01-01

    Background: Pneumonia is the single leading cause of death in children younger than 5 years of age. Chest physiotherapy is often prescribed as an additional therapy in children with pneumonia. Different chest physiotherapy techniques are available that aim to improve airway clearance, gas exchange and reduce the work of breathing. However, it is unclear if these techniques are effective in this population.Objective: The present review aimed to determine the efficacy of different chest physiot...

  15. Optical compensation device for chest film radiography

    Science.gov (United States)

    Gould, Robert G.; Hasegawa, Bruce H.; DeForest, Sherman E.; Schmidt, Gregory W.; Hier, Richard G.

    1990-07-01

    Although chest radiography is the most commonly performed radiographic examination and one of the most valuable and cost-effective studies in medicine it suffers from relatively high error rates in both missing pathology and false positive interpretations. Detectability of lung nodules and other structures in underpenetrated regions of the chest film can be improved by both exposure and optical compensation but current compensation systems require major capital cost or a significant change in normal clinical practice. A new optical compensation system called the " Intelligent X-Ray Illuminator" (IXI) automatically and virtually instantaneously generates a patient-specific optical unsharp mask that is projected directly on a radiograph. When a radiograph is placed on the IXI which looks much like a conventional viewbox it acquires a low-resolution electronic image of this film from which the film transmission is derived. The transmission information is inverted and blurred in an image processor to form an unsharp mask which is fed into a spatial light modulator (SLM) placed between a light source and the radiograph. The SLM tailors the viewbox luminance by decreasing illumination to underexposed (i. e. transmissive) areas of the radiograph presenting the observer with an optically unsharp-masked image. The IXI uses the original radiograph and will allow it to be viewed on demand with conventional (uniform illumination. Potentially the IXI could introduce the known beneficial aspects of optical unsharp masking into radiology at low capital

  16. Cross-chest liposuction in gynaecomastia

    Directory of Open Access Journals (Sweden)

    Biju Murali

    2011-01-01

    Full Text Available Background: Gynaecomastia is usually treated with liposuction or liposuction with excision of the glandular tissue. The type of surgery chosen depends on the grade of the condition. Objective: Because gynaecomastia is treated primarily as a cosmetic procedure, we aimed at reducing the invasiveness of the surgery. Materials and Methods: The technique complies with all recommended protocols for different grades of gynaecomastia. It uses liposuction, gland excision, or both, leaving only minimal post-operative scars. The use of cross-chest liposuction through incisions on the edge of the areola helps to get rid of all the fat under the areola without an additional scar as in the conventional method. Results: This is a short series of 20 patients, all with bilateral gynaecomastia (i.e., 40 breasts, belonging to Simon′s Stage 1 and 2, studied over a period of 2 years. The average period of follow-up was 15 months. Post-operative complications were reported in only two cases, with none showing long-term complications or issues specifically due to the procedure. Conclusions : Cross-chest liposuction for gynaecomastia is a simple yet effective surgical tool in bilateral gynaecomastia treatment to decrease the post-operative scars. The use of techniques like incision line drain placement and post-drain removal suturing of wounds aid in decreasing the scar.

  17. Chest trauma in children: current imaging guidelines and techniques.

    LENUS (Irish Health Repository)

    Moore, Michael A

    2011-09-01

    Given the heterogeneous nature of pediatric chest trauma, the optimal imaging approach is tailored to the specific patient. Chest radiography remains the most important imaging modality for initial triage. The decision to perform a chest computed tomography scan should be based on the nature of the trauma, the child\\'s clinical condition, and the initial radiographic findings, taking the age-related pretest probabilities of serious injury into account. The principles of as low as reasonably achievable and Image Gently should be followed. The epidemiology and pathophysiology, imaging techniques, characteristic findings, and evidence-based algorithms for pediatric chest trauma are discussed.

  18. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    Directory of Open Access Journals (Sweden)

    João Palas

    2014-01-01

    Full Text Available Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  19. Staphylococcus aureus sternal osteomyelitis: a rare cause of chest pain

    Directory of Open Access Journals (Sweden)

    Kaur M

    2015-10-01

    Full Text Available Chest pain is a common presenting symptom with a broad differential. Life-threatening cardiac and pulmonary etiologies of chest pain should be evaluated first. However, it is critical to perform a thorough assessment for other sources of chest pain in order to limit morbidity and mortality from less common causes. We present a rare case of a previously healthy 45 year old man who presented with focal, substernal, reproducible chest pain and Staphylococcus aureus bacteremia who was later found to have primary Staphylococcus aureus sternal osteomyelitis.

  20. Multidetector computer tomography: evaluation of blunt chest trauma in adults.

    Science.gov (United States)

    Palas, João; Matos, António P; Mascarenhas, Vasco; Herédia, Vasco; Ramalho, Miguel

    2014-01-01

    Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  1. Measuring chest circumference change during respiration with an electromagnetic biosensor.

    Science.gov (United States)

    Padasdao, Bryson; Shahhaidar, Ehsaneh; Boric-Lubecke, Olga

    2013-01-01

    In this paper, an off-the-shelf DC motor is modified into a chest belt and used to successfully measure circumference change on a mechanical chest model, while simultaneously harvesting significant power. Chest circumference change can provide information on tidal volume, which is vital in assessing lung function. The chest circumference change is calculated from the motor's voltage output. Calculated values are within 0.95mm of measured circumference changes, with a standard deviation of 0.37mm. The wearable motor can also harvest at least 29.4µW during normal breathing.

  2. Intraoperative high field magnetic resonance imaging combined with pyramidal tract navigation for resection of thalamic gliomas%术中高场强磁共振联合锥体束导航在丘脑胶质瘤切除手术中的应用

    Institute of Scientific and Technical Information of China (English)

    吴东东; 陈晓雷; 耿杰峰; 张猛; 白少聪; 王群; 马晓东; 许百男

    2015-01-01

    Objective To explore the clinical value of high field iMRI combined with pyramidal tract navigation on the resection of thalamic gliomas. Methods Clinical data about 28 patients with thalamic gliomas admitted to our hospital from March 2009 to April 2014 were retrospectively analyzed. All patients underwent microsurgery aided by iMRI combined pyramidal tract navigation. The extent of resection (EOR) of tumors, pre- and post-operative Karnofsky performance scale (KPS) and myodynamia were evaluated. Results iMRI scanning revealed residual tumors in 22 of 28 patients, and 15 patients received further resection which increased EOR. Three weeks after surgery, neurological functions improved or kept no change in 22 cases, and 6 cases experienced neurological function decline, however, the KPS score of these 6 patients were higher than 60, which suggested that the patients could take care of themselves. Conclusion iMRI combined with pyramidal tract navigation is helpful to maximize the resection of thalamic gliomas and decrease incidence of the neurologic deficits.%目的:探讨术中高场强磁共振联合锥体束导航在丘脑胶质瘤切除手术中的应用价值。方法回顾性研究2009年3月-2014年4月本院神经外科收治的28例接受1.5 T高场强术中磁共振联合锥体束导航辅助显微切除手术的丘脑胶质瘤患者临床资料,分析评估了所有患者的肿瘤切除程度、术前术后行为状态评分(Karnofsky performance scale,KPS)和肌力。结果28例患者中有22例术中扫描后发现肿瘤残留,其中15例患者的残留肿瘤得以进一步切除,提高了肿瘤切除程度。术后3周,22例神经功能改善或同术前,6例神经功能下降,但是功能下降者KPS均>60,即生活均可自理。结论术中高场强磁共振联合锥体束导航有助于提高丘脑胶质瘤切除程度,减少术后运动功能障碍的发生率。

  3. Ideal charge-density-wave order in the high-field state of superconducting YBCO

    Science.gov (United States)

    Jang, H.; Lee, W.-S.; Nojiri, H.; Matsuzawa, S.; Yasumura, H.; Nie, L.; Maharaj, A. V.; Gerber, S.; Liu, Y.-J.; Mehta, A.; Bonn, D. A.; Liang, R.; Hardy, W. N.; Burns, C. A.; Islam, Z.; Song, S.; Hastings, J.; Devereaux, T. P.; Shen, Z.-X.; Kivelson, S. A.; Kao, C.-C.; Zhu, D.; Lee, J.-S.

    2016-12-01

    The existence of charge-density-wave (CDW) correlations in cuprate superconductors has now been established. However, the nature of the CDW ground state has remained uncertain because disorder and the presence of superconductivity typically limit the CDW correlation lengths to only a dozen unit cells or less. Here we explore the field-induced 3D CDW correlations in extremely pure detwinned crystals of YBa2Cu3O2 (YBCO) ortho-II and ortho-VIII at magnetic fields in excess of the resistive upper critical field (Hc2Hc2) where superconductivity is heavily suppressed. We observe that the 3D CDW is unidirectional and possesses a long in-plane correlation length as well as significant correlations between neighboring CuO2 planes. It is significant that we observe only a single sharply defined transition at a critical field proportional to Hc2Hc2, given that the field range used in this investigation overlaps with other high-field experiments including quantum oscillation measurements. The correlation volume is at least two to three orders of magnitude larger than that of the zero-field CDW. This is by far the largest CDW correlation volume observed in any cuprate crystal and so is presumably representative of the high-field ground state of an “ideal” disorder-free cuprate.

  4. MAGNET

    CERN Multimedia

    B. Curé

    MAGNET During the winter shutdown, the magnet subsystems went through a full maintenance. The magnet was successfully warmed up to room temperature beginning of December 2008. The vacuum was broken later on by injecting nitrogen at a pressure just above one atmosphere inside the vacuum tank. This was necessary both to prevent any accidental humidity ingress, and to allow for a modification of the vacuum gauges on the vacuum tank and maintenance of the diffusion pumps. The vacuum gauges had to be changed, because of erratic variations on the measurements, causing spurious alarms. The new type of vacuum gauges has been used in similar conditions on the other LHC experiments and without problems. They are shielded against the stray field. The lubricants of the primary and diffusion pumps have been changed. Several minor modifications were also carried out on the equipment in the service cavern, with the aim to ease the maintenance and to allow possible intervention during operation. Spare sensors have been bough...

  5. MAGNET

    CERN Multimedia

    B. Curé

    2013-01-01

    The magnet is fully stopped and at room temperature. The maintenance works and consolidation activities on the magnet sub-systems are progressing. To consolidate the cryogenic installation, two redundant helium compressors will be installed as ‘hot spares’, to avoid the risk of a magnet downtime in case of a major failure of a compressor unit during operation. The screw compressors, their motors, the mechanical couplings and the concrete blocks are already available and stored at P5. The metallic structure used to access the existing compressors in SH5 will be modified to allow the installation of the two redundant ones. The plan is to finish the installation and commissioning of the hot spare compressors before the summer 2014. In the meantime, a bypass on the high-pressure helium piping will be installed for the connection of a helium drier unit later during the Long Shutdown 1, keeping this installation out of the schedule critical path. A proposal is now being prepared for the con...

  6. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    The magnet worked very well at 3.8 T as expected, despite a technical issue that manifested twice in the cryogenics since June. All the other magnet sub-systems worked without flaw. The issue in the cryogenics was with the cold box: it could be observed that the cold box was getting progressively blocked, due to some residual humidity and air accumulating in the first thermal exchanger and in the adsorber at 65 K. This was later confirmed by the analysis during the regeneration phases. An increase in the temperature difference between the helium inlet and outlet across the heat exchanger and a pressure drop increase on the filter of the adsorber were observed. The consequence was a reduction of the helium flow, first compensated by the automatic opening of the regulation valves. But once they were fully opened, the flow and refrigeration power reduced as a consequence. In such a situation, the liquid helium level in the helium Dewar decreased, eventually causing a ramp down of the magnet current and a field...

  7. MAGNET

    CERN Multimedia

    Benoit Curé.

    The magnet operation restarted end of June this year. Quick routine checks of the magnet sub-systems were performed at low current before starting the ramps up to higher field. It appeared clearly that the end of the field ramp down to zero was too long to be compatible with the detector commissioning and operations plans. It was decided to perform an upgrade to keep the ramp down from 3.8T to zero within 4 hours. On July 10th, when a field of 1.5T was reached, small movements were observed in the forward region support table and it was decided to fix this problem before going to higher field. At the end of July the ramps could be resumed. On July 28th, the field was at 3.8T and the summer CRAFT exercise could start. This run in August went smoothly until a general CERN wide power cut took place on August 3rd, due to an insulation fault on the high voltage network outside point 5. It affected the magnet powering electrical circuit, as it caused the opening of the main circuit breakers, resulting in a fast du...

  8. High-field Zeeman and Paschen-Back effects at high pressure in oriented ruby

    Science.gov (United States)

    Millot, Marius; Broto, Jean-Marc; Gonzalez, Jesus

    2008-10-01

    High-field Zeeman and Paschen-Back effects have been observed in single crystals of ruby submitted to hydrostatic pressure up to 10 GPa. A specific setup with a miniature diamond-anvil cell has been developed to combine high pressure and pulsed magnetic fields and to perform magnetophotoluminescence measurements. Careful analysis of low-temperature (4.2 and 77 K) photoluminescence spectra with a 56 T magnetic field applied along the c axis allows for the rectification of the assignment of observed emission lines to corresponding Zeeman-split levels. Besides, the intrinsic Zeeman-splitting factors of excited states reveal a linear pressure-induced increase. This enhancement is a signature of an increase in trigonal distortion induced by hydrostatic pressure. Moreover, spectra with magnetic field perpendicular to crystallographic c axis exhibit a Paschen-Back effect reflecting the progressive alignment of Cr3+ ions spin along the applied field. However, no pressure modification is observed in this compound, contrarily to the Heisenberg-to-Ising spin character pressure-induced transition observed in alexandrite.

  9. ANALYSIS OF HIGH FIELD NON-LINEAR LOSSES ON SRF SURFACES DUE TO SPECIFIC TOPOGRAPHIC ROUGHNESS

    Energy Technology Data Exchange (ETDEWEB)

    Chen Xu,Charles Reece,Michael Kelley

    2012-07-01

    The high-field performance of SRF cavities will eventually be limited by the realization of fundamental material limits, whether it is Hc1 or Hsh, or some derivative thereof, at which the superconductivity is lost. Before reaching this fundamental field limit at the macro level, it must be encountered at localized, perhaps microscopic, sites of field enhancement due to local topography. If such sites are small enough, they may produce thermally stabilized normal-conducting regions which contribute non-linear losses when viewed from the macro resonant field perspective, and thus produce degradation in Q0. We have undertaken a calculation of local surface magnetic field enhancement from specific fine topographic structure by conformal mapping method and numerically. A solution of the resulting normal conducting volume has been derived and the corresponding RF Ohmic loss simulated.

  10. High field transport properties of InAs/AlGaSb quantum wires

    Science.gov (United States)

    Sasa, S.; Sugihara, T.; Tada, K.; Izumiya, S.; Yamamoto, Y.; Inoue, M.

    1996-09-01

    We demonstrate the successful fabrication of multiple quantum wire structures using InAs/AlGaSb heterostructures and report on their transport properties. We have performed magnetotransport measurements on the various width of the wires ranging between 0.2 and 0.4 μm. One-dimensional transport properties confirmed by magnetic depopulation were observed up to 0.4-μm-wide wires, and the sublevel spacing was as large as 5.9 meV for 0.2-μm-wide wires. This demonstrates the advantageous feature of InAs/AlGaSb heterostructures for realizing quantum devices operating at higher temperatures. High field transport properties also reveal their advantageous features.

  11. The new high field photoexcitation muon spectrometer at the ISIS pulsed neutron and muon source

    CERN Document Server

    Yokoyama, K; Murahari, P; Wang, K; Dunstan, D J; Waller, S P; McPhail, D J; Hillier, A D; Henson, J; Harper, M R; Heathcote, P; Drew, A J

    2016-01-01

    A high power pulsed laser system has been installed on the high magnetic field muon instrument (HiFi) at the ISIS pulsed neutron and muon source, situated at the STFC Rutherford Appleton Laboratory in the UK. The upgrade enables one to perform light-pump muon-probe experiments under a high field, which opens up a brand-new area in the muon spin spectroscopy. In this report we overview the principle of the HiFi Laser system, and describe the newly developed techniques and devices that enable a controlled photoexcitation in the muon instrument. A demonstration experiment illustrates the unique combination of the photoexcited system and avoided level crossing technique.

  12. Susceptibility Contrast in High Field MRI of Human Brain as a Function of Tissue Iron Content

    Science.gov (United States)

    Yao, Bing; Li, Tie-Qiang; van Gelderen, Peter; Shmueli, Karin; de Zwart, Jacco A.; Duyn, Jeff H.

    2009-01-01

    Magnetic susceptibility provides an important contrast mechanism for MRI. Increasingly, susceptibility-based contrast is being exploited to investigate brain tissue microstructure and to detect abnormal levels of brain iron as these have been implicated in a variety of neuro-degenerative diseases. However, it remains unclear to what extent magnetic susceptibility-related contrast at high field relates to actual brain iron concentrations. In this study, we performed susceptibility weighted imaging as a function of field strength on healthy brains in vivo and post-mortem brain tissues at 1.5T, 3T and 7T. Iron histology was performed on the tissue samples for comparison. The calculated susceptibility-related parameters R2* and signal frequency shift in four iron-rich regions (putamen, globus pallidus, caudate, and thalamus) showed an almost linear dependence (r=0.90 for R2*; r=0.83 for phase, p<0.01) on field strength, suggesting that potential ferritin saturation effects are not relevant to susceptibility-weighted contrast for field strengths up to 7T. The R2* dependence on the putative (literature-based) iron concentration was 0.048 Hz/Tesla/ppm. The histological data from brain samples confirmed the linear dependence of R2* on field strength and showed a slope against iron concentration of 0.0099 Hz/Tesla/ppm dry-weight, which is equivalent to 0.05 Hz/Tesla/ppm wet-weight and closely matched the calculated value in vivo. These results confirm the validity of using susceptibility-weighted contrast as an indicator of iron content in iron-rich brain regions. The absence of saturation effects opens the way to exploit the benefits of MRI at high field strengths for the detection of iron distributions with high sensitivity and resolution. PMID:19027861

  13. A feasibility study of high-strength Bi-2223 conductor for high-field solenoids

    Science.gov (United States)

    Godeke, A.; Abraimov, D. V.; Arroyo, E.; Barret, N.; Bird, M. D.; Francis, A.; Jaroszynski, J.; Kurteva, D. V.; Markiewicz, W. D.; Marks, E. L.; Marshall, W. S.; McRae, D. M.; Noyes, P. D.; Pereira, R. C. P.; Viouchkov, Y. L.; Walsh, R. P.; White, J. M.

    2017-03-01

    We performed a feasibility study on a high-strength Bi{}2-xPb x Sr2Ca2Cu3O{}10-x(Bi-2223) tape conductor for high-field solenoid applications. The investigated conductor, DI-BSCCO Type HT-XX, is a pre-production version of Type HT-NX, which has recently become available from Sumitomo Electric Industries. It is based on their DI-BSCCO Type H tape, but laminated with a high-strength Ni-alloy. We used stress–strain characterizations, single- and double-bend tests, easy- and hard-way bent coil-turns at various radii, straight and helical samples in up to 31.2 T background field, and small 20-turn coils in up to 17 T background field to systematically determine the electro-mechanical limits in magnet-relevant conditions. In longitudinal tensile tests at 77 K, we found critical stress- and strain-levels of 516 MPa and 0.57%, respectively. In three decidedly different experiments we detected an amplification of the allowable strain with a combination of pure bending and Lorentz loading to ≥slant 0.92 % (calculated elastically at the outer tape edge). This significant strain level, and the fact that it is multi-filamentary conductor and available in the reacted and insulated state, makes DI-BSCCO HT-NX highly suitable for very high-field solenoids, for which high current densities and therefore high loads are required to retain manageable magnet dimensions.

  14. An unusual cause for recurrent chest infections.

    LENUS (Irish Health Repository)

    Lobo, Ronstan

    2012-10-01

    We present a case of an elderly non-smoking gentleman who, since 2005, had been admitted multiple times for recurrent episodes of shortness of breath, wheeze, cough and sputum. The patient was treated as exacerbations of chronic obstructive pulmonary disease (COPD) and\\/or lower respiratory tract infections. Bronchoscopy was done which revealed multiple hard nodules in the trachea and bronchi with posterior tracheal wall sparing. Biopsies confirmed this as tracheopathia osteochondroplastica (TO). He had increasing frequency of admission due to methicillin-resistant Staphylococcus aureus and pseudomonas infections, which failed to clear despite intravenous, prolonged oral and nebulised antibiotics. The patient developed increasing respiratory distress and respiratory failure. The patient died peacefully in 2012. This case report highlights the typical pathological and radiological findings of TO and the pitfalls of misdiagnosing patients with recurrent chest infections as COPD.

  15. Pleural fluids associated with chest infection.

    Science.gov (United States)

    Quadri, Amal; Thomson, Anne H

    2002-12-01

    Pleural effusions are commonly associated with pneumonias and a small number of these progress to empyema. An understanding of the physiology and pathophysiology of pleural fluid aids the clinician in the management of empyema. There remains much debate about the optimal treatment of empyema in children. Early recognition of the condition is important since delayed therapy may result in unnecessary morbidity. Conventional management with high dose parenteral antibiotics and chest tube drainage remains the mainstay of therapy. However, this treatment modality may fail if the pleural fluid becomes viscous and loculated and, therefore, a more aggressive approach is required. Intrapleural fibrinolytic therapy has been shown to decrease the length of hospital stay and may reduce the need for surgical intervention. The prognosis in children with parapneumonic empyema is excellent with the vast majority retaining normal lung function at long term follow-up.

  16. Diagnosing Myocardial Contusion after Blunt Chest Trauma

    Directory of Open Access Journals (Sweden)

    Zahra Alborzi

    2016-10-01

    Full Text Available A myocardial contusion refers to a bruise of the cardiac muscle, the severity of which can vary depending on the severity of the injury and when the injury occurs. It is a major cause of rapid death which happens after blunt chest trauma and should be suspected at triage in the emergency department. We demonstrated that suspected myocardial contusion patients who have normal electrocardiograms (ECGs and biomarker tests can be safely discharged. However, if the test results are abnormal, the next steps should be echocardiography and more advanced measures. Diagnosing myocardial contusion is very difficult because of its nonspecific symptoms. If a myocardial contusion happens, cardiogenic shock or arrhythmia must be anticipated, and the patient must be carefully monitored.

  17. Relevance of an incidental chest finding

    Science.gov (United States)

    Cortés-Télles, Arturo; Mendoza, Daniel

    2012-01-01

    Solitary pulmonary nodule represents 0.2% of incidental findings in routine chest X-ray images. One of the main diagnoses includes lung cancer in which small-cell subtype has a poor survival rate. Recently, a new classification has been proposed including the very limited disease stage (VLD stage) or T1-T2N0M0 with better survival rate, specifically in those patients who are treated with surgery. However, current recommendations postulate that surgery remains controversial as a first-line treatment in this stage. We present the case of a 46-year-old female referred to our hospital with a preoperative diagnosis of a solitary pulmonary nodule. On initial approach, a biopsy revealed a small cell lung cancer. She received multimodal therapy with surgery, chemotherapy, and prophylactic cranial irradiation and is currently alive without recurrence on a 2-year follow-up. PMID:22345914

  18. Tuberculosis abscess of the chest wall.

    Science.gov (United States)

    Cataño, Juan; Perez, Jefferson

    2014-10-01

    A 42-year-old male presented in June of 2011 with nocturnal fevers, night sweats, an 8-kg weight loss, and a cutaneous right chest wall mass. In March of 2013, a computed tomographic scan of the thorax showed a 54 × 18 × 26-mm right lower lobe mass with peripheral calcifications, and in May of 2013, he was admitted for a segmental lobectomy, in which histologic examination of the pulmonary tissue revealed granulomas with multinucleated giant cells. The tissue was negative for acid-fast bacillae on Ziehl-Neelsen stain, and culture grew Mycobacterium tuberculosis. Therefore, he was started on four first-line antituberculosis medications and showed rapid symptomatic improvement.

  19. Short-lived charge-transfer excitons in organic photovoltaic cells studied by high-field magneto-photocurrent.

    Science.gov (United States)

    Devir-Wolfman, Ayeleth H; Khachatryan, Bagrat; Gautam, Bhoj R; Tzabary, Lior; Keren, Amit; Tessler, Nir; Vardeny, Z Valy; Ehrenfreund, Eitan

    2014-07-29

    The main route of charge photogeneration in efficient organic photovoltaic cells based on bulk hetero-junction donor-acceptor blends involves short-lived charge-transfer excitons at the donor-acceptor interfaces. The cell efficiency is critically affected by the charge-transfer exciton recombination and dissociation processes. By measuring the magneto-photocurrent under ambient conditions at room temperature, we show here that magnetic field-induced spin-mixing among the charge-transfer exciton spin sublevels occurs in fields up to at least 8.5 Tesla. The resulting magneto-photocurrent increases at high fields showing non-saturating behaviour up to the highest applied field. We attribute the observed high-field spin-mixing mechanism to the difference in the donor-acceptor g-factors. The non-saturating magneto-photocurrent response at high field indicates that there exist charge-transfer excitons with lifetime in the sub-nanosecond time domain. The non-Lorentzian high-field magneto-photocurrent response indicates a dispersive decay mechanism that originates due to a broad distribution of charge-transfer exciton lifetimes.

  20. Clinical assessment of chest pain and guidelines for imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gruettner, J., E-mail: joachim.gruettner@umm.de [1st Department of Medicine (Cardiology), University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim (Germany); Henzler, T. [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim (Germany); Sueselbeck, T. [1st Department of Medicine (Cardiology), University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim (Germany); Fink, C. [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim (Germany); Borggrefe, M.; Walter, T. [1st Department of Medicine (Cardiology), University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim (Germany)

    2012-12-15

    For many emergency facilities, risk assessment of patients with diffuse chest pain still poses a major challenge. In their currently valid recommendations, the international cardiological societies have defined a standardized assessment of the prognostically relevant cardiac risk criteria. Here the classic sequence of basic cardiac diagnostics including case history (cardiac risk factors), physical examination (haemodynamic and respiratory vital parameters), ECG (ST segment analysis) and laboratory risk markers (troponin levels) is paramount. The focus is, on the one hand, on timely indication for percutaneous catheterization, especially in patients at high cardiac risk with or without ST-segment elevation in the ECG, and, on the other hand, on the possibility of safely discharging patients with intermediate or low cardiac risk after non-invasive exclusion of a coronary syndrome. For patients in the intermediate or low risk group, physical or pharmacological stress testing in combination with scintigraphy, echocardiography or magnetic resonance imaging is recommended in addition to basic diagnostics. Moreover, the importance of non-invasive coronary imaging, primarily cardiac CT angiography (CCTA), is increasing. Current data show that in intermediate or low risk patients this method is suitable to reliably rule out coronary heart disease. In addition, attention is paid to the major differential diagnoses of acute coronary syndrome, particularly pulmonary embolism and aortic dissection. Here the diagnostic method of choice is thoracic CT, possibly also in combination with CCTA aiming at a triple rule-out.

  1. Resuscitation, prolonged cardiac arrest, and an automated chest compression device

    DEFF Research Database (Denmark)

    Risom, Martin; Jørgensen, Henrik; Rasmussen, Lars S;

    2010-01-01

    The European Resuscitation Council's 2005 guidelines for cardiopulmonary resuscitation (CPR) emphasize the delivery of uninterrupted chest compressions of adequate depth during cardiac arrest.......The European Resuscitation Council's 2005 guidelines for cardiopulmonary resuscitation (CPR) emphasize the delivery of uninterrupted chest compressions of adequate depth during cardiac arrest....

  2. Automatic segmentation of pulmonary segments from volumetric chest CT scans.

    NARCIS (Netherlands)

    Rikxoort, E.M. van; Hoop, B. de; Vorst, S. van de; Prokop, M.; Ginneken, B. van

    2009-01-01

    Automated extraction of pulmonary anatomy provides a foundation for computerized analysis of computed tomography (CT) scans of the chest. A completely automatic method is presented to segment the lungs, lobes and pulmonary segments from volumetric CT chest scans. The method starts with lung segmenta

  3. Low dose computed tomography of the chest : Applications and limitations

    NARCIS (Netherlands)

    Gietema, H.A.

    2007-01-01

    In areas with a high intrinsic contrast such as the chest, radiation dose can be reduced for specific indications. Low dose chest CT is feasible and cannot only be applied for lung cancer screening, but also in daily routine and for early detection of lung destruction. We showed in a small sample of

  4. Chest physical therapy in acute viral bronchiolitis: an updated review.

    Science.gov (United States)

    Postiaux, Guy; Zwaenepoel, Bruno; Louis, Jacques

    2013-09-01

    We describe the various therapies for infant acute viral bronchiolitis and the contradictory results obtained with chest physical therapy. The treatment target is bronchial obstruction, which is a multifactorial phenomenon that includes edema, bronchoconstriction, and increased mucus production, with a clinical grading defined as severe, moderate, or mild. Chest physical therapy is revisited in its various modalities, according to preliminary scoring of the disease.

  5. Postpartum Pneumomediastinum: An Uncommon Cause for Chest Pain

    Directory of Open Access Journals (Sweden)

    Vladimir Revicky

    2010-01-01

    Full Text Available This case report refers to a 32-year-old primiparous woman with a mild asthma, who had a normal vaginal delivery in a birthing pool and developed an acute postpartum chest pain due to pneumomediastinum and subcutaneous chest emphysema. After 72 hours of observation, she was discharged home without any residual symptoms.

  6. Taking heartache to heart: Empirical psychological modelling of chest pain

    NARCIS (Netherlands)

    A.W. Serlie (Alec)

    1996-01-01

    textabstractThe chest pain of patients visiting a cardiology out-patient's clinic is most often caused by coronary atherosclerosis, which induces an oxygen shortage in the heartmuscle and thereby pain. However, in approximately 30% of the chest pain patients no clear somatic cause can be found. Cont

  7. Giant pericardial cyst mimicking dextrocardia on chest X-ray.

    Science.gov (United States)

    Hamad, Hamad M; Galrinho, Ana; Abreu, João; Valente, Bruno; Bakero, Luis; Ferreira, Rui C

    2013-01-01

    Pericardial cysts are rare benign congenital malformations, usually small, asymptomatic and detected incidentally on chest X-ray as a mass located in the right costophrenic angle. Giant pericardial cysts are very uncommon and produce symptoms by compressing adjacent structures. In this report, the authors present a case of a symptomatic giant pericardial cyst incorrectly diagnosed as dextrocardia on chest X-ray.

  8. Measurement of characteristic leap interval between chest and falsetto registers

    NARCIS (Netherlands)

    Miller, DG; Svec, JG; Schutte, HK

    2002-01-01

    A markedly smaller time constant distinguishes a chest-falsetto leap from the more usual execution of a sung interval by muscular adjustments in the length and tension of the vocal folds. The features of such a chest-falsetto leap are examined in detail with respect to F-0, peak-to-peak amplitude of

  9. Effect of rib-cage structure on acoustic chest impedance

    DEFF Research Database (Denmark)

    Zimmermann, Niels Henrik; Møller, Henrik; Hansen, John;

    2011-01-01

    When a stethoscope is placed on the surface of the chest, the coupler picks up sound from heart and lungs transmitted through the tissues of the ribcage and from the surface of the skin. If the acoustic impedance of the chest surface is known, it is possible to optimize the coupler for picking up...

  10. Management of chest drainage tubes after lung surgery.

    Science.gov (United States)

    Satoh, Yukitoshi

    2016-06-01

    Since chest tubes have been routinely used to drain the pleural space, particularly after lung surgery, the management of chest tubes is considered to be essential for the thoracic surgeon. The pleural drainage system requires effective drainage, suction, and water-sealing. Another key point of chest tube management is that a water seal is considered to be superior to suction for most air leaks. Nowadays, the most common pleural drainage device attached to the chest tube is the three-bottle system. An electronic chest drainage system has been developed that is effective in standardizing the postoperative management of chest tubes. More liberal use of digital drainage devices in the postoperative management of the pleural space is warranted. The removal of chest tubes is a common procedure occurring almost daily in hospitals throughout the world. Extraction of the tube is usually done at the end of full inspiration or at the end of full expiration. The tube removal technique is not as important as how it is done and the preparation for the procedure. The management of chest tubes must be based on careful observation, the patient's characteristics, and the operative procedures that had been performed.

  11. Options for assessing and measuring chest wall motion.

    Science.gov (United States)

    Seddon, Paul

    2015-01-01

    Assessing chest wall motion is a basic and vital component in managing the child with respiratory problems, whether these are due to pathology in the lungs, airways, chest wall or muscles. Since the 1960s, clinical assessment has been supplemented with an ever-growing range of technological options for measuring chest wall motion, each with unique advantages and disadvantages. Measurements of chest wall motion can be used to: (1) Assess respiratory airflow and volume change, as a non-invasive alternative to measurement at the airway opening, (2) Monitor breathing over long periods of time, to identify apnoea and other types of sleep-disordered breathing, (3)Identify and quantify patterns of abnormal chest wall movement, whether between ribcage and abdominal components (thoracoabdominal asynchrony) or between different regions of the ribcage (eg in scoliosis and pectus excavatum). Measuring chest wall motion allows us to do things which simply cannot be done by more mainstream respiratory function techniques measuring flow at the airway opening: it allows respiratory airflow to be measured when it would otherwise be impossible, and it tells us how the different parts of the chest wall (eg ribcage vs abdomen, right vs left) are moving in order to generate that airflow. The basis of the different techniques available to assess and measure chest wall motion will be reviewed and compared, and their relevance to paediatric respiratory practice assessed.

  12. Segmentation of anatomical structures in chest CT scans

    NARCIS (Netherlands)

    van Rikxoort, E.M.

    2009-01-01

    In this thesis, methods are described for the automatic segmentation of anatomical structures from chest CT scans. First, a method to segment the lungs from chest CT scans is presented. Standard lung segmentation algorithms rely on large attenuation differences between the lungs and the surrounding

  13. Sexual, Physical, Verbal/Emotional Abuse and Unexplained Chest Pain

    Science.gov (United States)

    Eslick, Guy D.; Koloski, Natasha A.; Talley, Nicholas J.

    2011-01-01

    Objectives: Approximately one third of patients with non cardiac chest pain (NCCP) report a history of abuse, however no data exists on the prevalence of abuse among people with unexplained chest pain in the general population. We aimed to determine if there is a relationship between childhood sexual, physical, emotional abuse and unexplained…

  14. MAGNET

    CERN Multimedia

    B. Curé

    During the winter shutdown, the magnet subsystems went through a full maintenance. The magnet was successfully warmed up to room temperature beginning of December 2008. The vacuum was broken later on by injecting nitrogen at a pressure just above one atmosphere inside the vacuum tank. This was necessary both to prevent any accidental humidity ingress, and to allow for a modification of the vacuum gauges on the vacuum tank and maintenance of the diffusion pumps. The vacuum gauges had to be changed, because of erratic variations on the measurements, causing spurious alarms. The new type of vacuum gauges has been used in similar conditions on the other LHC experiments and without problems. They are shielded against the stray field. The lubricants of the primary and diffusion pumps have been changed. Several minor modifications were also carried out on the equipment in the service cavern, with the aim to ease the maintenance and to allow possible intervention during operation. Spare sensors have been bought. Th...

  15. MAGNET

    CERN Multimedia

    Benoit Curé

    The magnet subsystems resumed operation early this spring. The vacuum pumping was restarted mid March, and the cryogenic power plant was restarted on March 30th. Three and a half weeks later, the magnet was at 4.5 K. The vacuum pumping system is performing well. One of the newly installed vacuum gauges had to be replaced at the end of the cool-down phase, as the values indicated were not coherent with the other pressure measurements. The correction had to be implemented quickly to be sure no helium leak could be at the origin of this anomaly. The pressure measurements have been stable and coherent since the change. The cryogenics worked well, and the cool-down went quite smoothly, without any particular difficulty. The automated start of the turbines had to be fine-tuned to get a smooth transition, as it was observed that the cooling power delivered by the turbines was slightly higher than needed, causing the cold box to stop automatically. This had no consequence as the cold box safety system acts to keep ...

  16. Chest wall reconstruction in a pediatric patient with ectopia cordis.

    Science.gov (United States)

    Mohan, Raja; Peralta, Mat; Perez, Ramiro; Rosenkranz, Eliot R; Panthaki, Zubin J

    2010-08-01

    Ectopia cordis is defined as a congenital malposition of the heart outside of the thoracic cavity. It is a rare condition, and complete ectopia cordis can be a fatal condition. Successful surgical reconstruction of this defect has been reported but is uncommon. The general approach to reconstructing the chest wall involves repositioning the heart and providing adequate coverage of the chest wall defect. We describe our experience with a patient who had complete thoracic ectopia cordis treated with staged chest wall reconstruction. The first stage involved temporary closure with synthetic material, and the second stage involved definitive reconstruction with autologous bone and cartilage grafts supported with plates. The patient has been active and without complaints since the second stage and is awaiting tracheal decannulation. There have been a few descriptions of how to approach chest wall reconstruction in patients with ectopia cordis. The 2 stage method described can be considered to repair the chest wall defect in complete thoracic ectopia cordis.

  17. Electronic versus traditional chest tube drainage following lobectomy

    DEFF Research Database (Denmark)

    Lijkendijk, Marike; Licht, Peter B; Neckelmann, Kirsten

    2015-01-01

    OBJECTIVES: Electronic drainage systems have shown superiority compared with traditional (water seal) drainage systems following lung resections, but the number of studies is limited. As part of a medico-technical evaluation, before change of practice to electronic drainage systems for routine...... thoracic surgery, we conducted a randomized controlled trial (RCT) investigating chest tube duration and length of hospitalization. METHODS: Patients undergoing lobectomy were included in a prospective open label RCT. A strict algorithm was designed for early chest tube removal, and this decision...... time for chest tube removal, as well as length of hospitalization. RESULTS: A total of 105 patients were randomized. We found no significant difference between the electronic group and traditional group in optimal chest tube duration (HR = 0.83; 95% CI: 0.55-1.25; P = 0.367), actual chest tube duration...

  18. Alternative Contrast Mechanisms in High Field MR Microscopy.

    Science.gov (United States)

    Engelhardt, Robert Thomas

    1995-01-01

    In high-field MR Microscopy, the T_1 relaxation times may become long and converge while the T_2 relaxation times may become short and converge. As a result, much of the contrast is due solely to differences in spin density. The use of T_{1rho} as an alternative contrast parameter in high-field MR Microscopy has been explored here. To this end, MR Microscopy experiments have been performed using 2.0 and 9.4 Tesla Bruker MRI systems. Spectroscopy experiments at 9.4 Tesla were performed on several phantoms (5.75% agar gel, 1.0 mM MnCl_2, 7.3% and 20% gelatin). Imaging experiments were performed on two, 17.5 day old, perfusion fixed, mouse embryos, embedded in 7.3% gelatin to minimize drying and susceptibility differences. The relaxation times, T_1, T _2, and T_{1rho }, the signal to noise ratios (SNR) and contrast to noise ratios (CNR), have been measured for several types of tissue. The T_{1rho} relaxation times were measured at four locking field strengths, 0.7, 0.9, 1.3 and 1.7 G. T_1 and T_2 imaging experiments were performed using a conventional spin warp imaging sequence. T_{1rho } imaging experiments were performed using a presaturating spin locking pulse, followed by a conventional spin warp imaging sequence. Muscle, diencephalon, lung and liver were chosen for the relaxation time measurements as they offered both good tissue specificity and size. Both static and locking field dispersion of T _{1rho} were observed in the selected mouse embryo tissues. The observed T _{1rho} relaxation times were generally longer than the T_2 relaxation times, increased with locking field strength, and were consistently shorter at 9.4 Tesla than at 2.0 Tesla. The static field dispersion of T_ {1rho} and T_2 are both believed to be due, in part, to diffusion losses through susceptibility induced gradients. The losses are much smaller in the T_{1rho} images, and decrease as the locking pulse is increased. Finally, under certain circumstances, T_{1rho }-weighting could produce

  19. High-field transport properties of a P-doped BaFe2As2 film on technical substrate

    Science.gov (United States)

    Iida, Kazumasa; Sato, Hikaru; Tarantini, Chiara; Hänisch, Jens; Jaroszynski, Jan; Hiramatsu, Hidenori; Holzapfel, Bernhard; Hosono, Hideo

    2017-01-01

    High temperature (high-Tc) superconductors like cuprates have superior critical current properties in magnetic fields over other superconductors. However, superconducting wires for high-field-magnet applications are still dominated by low-Tc Nb3Sn due probably to cost and processing issues. The recent discovery of a second class of high-Tc materials, Fe-based superconductors, may provide another option for high-field-magnet wires. In particular, AEFe2As2 (AE: Alkali earth elements, AE-122) is one of the best candidates for high-field-magnet applications because of its high upper critical field, Hc2, moderate Hc2 anisotropy, and intermediate Tc. Here we report on in-field transport properties of P-doped BaFe2As2 (Ba-122) thin films grown on technical substrates by pulsed laser deposition. The P-doped Ba-122 coated conductor exceeds a transport Jc of 105 A/cm2 at 15 T for main crystallographic directions of the applied field, which is favourable for practical applications. Our P-doped Ba-122 coated conductors show a superior in-field Jc over MgB2 and NbTi, and a comparable level to Nb3Sn above 20 T. By analysing the E ‑ J curves for determining Jc, a non-Ohmic linear differential signature is observed at low field due to flux flow along the grain boundaries. However, grain boundaries work as flux pinning centres as demonstrated by the pinning force analysis.

  20. High-field transport properties of a P-doped BaFe2As2 film on technical substrate

    Science.gov (United States)

    Iida, Kazumasa; Sato, Hikaru; Tarantini, Chiara; Hänisch, Jens; Jaroszynski, Jan; Hiramatsu, Hidenori; Holzapfel, Bernhard; Hosono, Hideo

    2017-01-01

    High temperature (high-Tc) superconductors like cuprates have superior critical current properties in magnetic fields over other superconductors. However, superconducting wires for high-field-magnet applications are still dominated by low-Tc Nb3Sn due probably to cost and processing issues. The recent discovery of a second class of high-Tc materials, Fe-based superconductors, may provide another option for high-field-magnet wires. In particular, AEFe2As2 (AE: Alkali earth elements, AE-122) is one of the best candidates for high-field-magnet applications because of its high upper critical field, Hc2, moderate Hc2 anisotropy, and intermediate Tc. Here we report on in-field transport properties of P-doped BaFe2As2 (Ba-122) thin films grown on technical substrates by pulsed laser deposition. The P-doped Ba-122 coated conductor exceeds a transport Jc of 105 A/cm2 at 15 T for main crystallographic directions of the applied field, which is favourable for practical applications. Our P-doped Ba-122 coated conductors show a superior in-field Jc over MgB2 and NbTi, and a comparable level to Nb3Sn above 20 T. By analysing the E − J curves for determining Jc, a non-Ohmic linear differential signature is observed at low field due to flux flow along the grain boundaries. However, grain boundaries work as flux pinning centres as demonstrated by the pinning force analysis. PMID:28079117

  1. Diagnostic relevance of high field MRI in clinical neuroradiology: the advantages and challenges of driving a sports car

    Energy Technology Data Exchange (ETDEWEB)

    Wattjes, Mike P.; Barkhof, Frederik [VU University Medical Center, Department of Radiology, Amsterdam (Netherlands)

    2012-11-15

    High field MRI operating at 3 T is increasingly being used in the field of neuroradiology on the grounds that higher magnetic field strength should theoretically lead to a higher diagnostic accuracy in the diagnosis of several disease entities. This Editorial discusses the exhaustive review by Wardlaw and colleagues of research comparing 3 T MRI with 1.5 T MRI in the field of neuroradiology. Interestingly, the authors found no convincing evidence of improved image quality, diagnostic accuracy, or reduced total examination times using 3 T MRI instead of 1.5 T MRI. These findings are highly relevant since a new generation of high field MRI systems operating at 7 T has recently been introduced. (orig.)

  2. High-resolution T2-weighted cervical cancer imaging : a feasibility study on ultra-high-field 7.0-T MRI with an endorectal monopole antenna

    NARCIS (Netherlands)

    Hoogendam, Jaap; van Kalleveen, Irene; Arteaga de Castro, Catalina; Raaijmakers, AJE; Verheijen, René H M; van Den Bosch, Maurice A A J; Klomp, DWJ; Zweemer, RP; Veldhuis, Wouter B.

    2017-01-01

    Objectives: We studied the feasibility of high-resolution T2-weighted cervical cancer imaging on an ultra-high-field 7.0-T magnetic resonance imaging (MRI) system using an endorectal antenna of 4.7-mm thickness. Methods: A feasibility study on 20 stage IB1–IIB cervical cancer patients was conducted.

  3. Control and data acquisition systems for high field superconducting wigglers

    CERN Document Server

    Batrakov, A; Karpov, G; Kozak, V; Kuzin, M; Kuper, E; Mamkin, V; Mezentsev, N A; Repkov, V V; Selivanov, A; Shkaruba, V A

    2001-01-01

    This paper describes the control and DAQ system of superconducting wigglers with magnetic field range up to 10.3 T. The first version of the system controls a 7 T superconducting wiggler prepared for installation at Bessy-II (Germany). The second one controls a 10 T wiggler which is under testing now at the SPring-8 site (Japan). Both systems are based on VME apparatus. The set of specialized VME modules is elaborated to arrange wiggler power supply control, full time wiggler monitoring, and magnetic field high accuracy measurement and field stabilization. The software for the control of the wigglers is written in C language for VxWorks operation system for a Motorola-162 VME controller. The task initialization, stops and acquisition of the data can be done from the nearest personal computer (FTP host for VME), or from the remote system as well.

  4. High-field phase-diagram of Fe arsenide superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Y.J.; Jaroszynski, J.; Yamamoto, A.; Gurevich, A.; Riggs, S.C.; Boebinger, G.S.; Larbalestier, D. [National High Magnetic Field Laboratory, Florida State University, Tallahassee-FL 32310 (United States); Wen, H.H. [Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Zhigadlo, N.D.; Katrych, S.; Bukowski, Z.; Karpinski, J. [Laboratory for Solid State Physics, ETH Zuerich, CH-8093 Zuerich (Switzerland); Liu, R.H.; Chen, H.; Chen, X.H. [Hefei National Laboratory for Physical Science a Microscale and Department of Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Balicas, L., E-mail: balicas@magnet.fsu.ed [National High Magnetic Field Laboratory, Florida State University, Tallahassee-FL 32310 (United States)

    2009-05-01

    Here, we report an overview of the phase-diagram of single-layered and double-layered Fe arsenide superconductors at high magnetic fields. Our systematic magneto-transport measurements of polycrystalline SmFeAsO{sub 1-x}F{sub x} at different doping levels confirm the upward curvature of the upper critical magnetic field H{sub c2}(T) as a function of temperature T defining the phase boundary between the superconducting and metallic states for crystallites with the ab planes oriented nearly perpendicular to the magnetic field. We further show from measurements on single-crystals that this feature, which was interpreted in terms of the existence of two superconducting gaps, is ubiquitous among both series of single- and double-layered compounds. In all compounds explored by us the zero temperature upper critical field H{sub c2}(0), estimated either through the Ginzburg-Landau or the Werthamer-Helfand-Hohenberg single gap theories, strongly surpasses the weak-coupling Pauli paramagnetic limiting field. This clearly indicates the strong-coupling nature of the superconducting state and the importance of magnetic correlations for these materials. Our measurements indicate that the superconducting anisotropy, as estimated through the ratio of the effective masses gamma = (m{sub c}/m{sub ab}){sup 1/2} for carriers moving along the c-axis and the ab-planes, respectively, is relatively modest as compared to the high-T{sub c} cuprates, but it is temperature, field and even doping dependent. Finally, our preliminary estimations of the irreversibility field H{sub m}(T), separating the vortex-solid from the vortex-liquid phase in the single-layered compounds, indicates that it is well described by the melting of a vortex lattice in a moderately anisotropic uniaxial superconductor.

  5. A Clinical Trial of a Computer Diagnosis Program for Chest Pain

    Science.gov (United States)

    1990-12-07

    infection, myocardial infarction, and non-specific chest pain. The category " Angina " included both stable and unstable angina . Chest infection was...is suitable for use by corpsmen at sea. THE FINDINGS 132 patients with confirmed diagnoses of chest pain (myocardial infarction, angina , chest ...sea with chest pain. The diagnostic accuracy of the program for three common and serious causes of chest pain -- myocardial infarction (MI), angina

  6. Scoping study for compact high-field superconducting net energy tokamaks

    Science.gov (United States)

    Mumgaard, R. T.; Greenwald, M.; Freidberg, J. P.; Wolfe, S. M.; Hartwig, Z. S.; Brunner, D.; Sorbom, B. N.; Whyte, D. G.

    2016-10-01

    The continued development and commercialization of high temperature superconductors (HTS) may enable the construction of compact, net-energy tokamaks. HTS, in contrast to present generation low temperature superconductors, offers improved performance in high magnetic fields, higher current density, stronger materials, higher temperature operation, and simplified assembly. Using HTS along with community-consensus confinement physics (H98 =1) may make it possible to achieve net-energy (Q>1) or burning plasma conditions (Q>5) in DIII-D or ASDEX-U sized, conventional aspect ratio tokamaks. It is shown that, by operating at high plasma current and density enabled by the high magnetic field (B>10T), the required triple products may be achieved at plasma volumes under 20m3, major radii under 2m, with external heating powers under 40MW. This is at the scale of existing devices operated by laboratories, universities and companies. The trade-offs in the core heating, divertor heat exhaust, sustainment, stability, and proximity to known plasma physics limits are discussed in the context of the present tokamak experience base and the requirements for future devices. The resulting HTS-based design space is compared and contrasted to previous studies on high-field copper experiments with similar missions. The physics exploration conducted with such HTS devices could decrease the real and perceived risks of ITER exploitation, and aid in quickly developing commercially-applicable tokamak pilot plants and reactors.

  7. Nitrogen detected TROSY at high field yields high resolution and sensitivity for protein NMR

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Koh [National Institute for Advanced Industrial Science and Technology, Molecular Profiling Research Center for Drug Discovery (Japan); Arthanari, Haribabu [Harvard Medical School, Department of Biochemistry and Molecular Pharmacology (United States); Shimada, Ichio, E-mail: shimada@iw-nmr.f.u-tokyo.ac.jp [National Institute for Advanced Industrial Science and Technology, Molecular Profiling Research Center for Drug Discovery (Japan); Wagner, Gerhard, E-mail: gerhard-wagner@hms.harvard.edu [Harvard Medical School, Department of Biochemistry and Molecular Pharmacology (United States)

    2015-12-15

    Detection of {sup 15}N in multidimensional NMR experiments of proteins has sparsely been utilized because of the low gyromagnetic ratio (γ) of nitrogen and the presumed low sensitivity of such experiments. Here we show that selecting the TROSY components of proton-attached {sup 15}N nuclei (TROSY {sup 15}N{sub H}) yields high quality spectra in high field magnets (>600 MHz) by taking advantage of the slow {sup 15}N transverse relaxation and compensating for the inherently low {sup 15}N sensitivity. The {sup 15}N TROSY transverse relaxation rates increase modestly with molecular weight but the TROSY gain in peak heights depends strongly on the magnetic field strength. Theoretical simulations predict that the narrowest line width for the TROSY {sup 15}N{sub H} component can be obtained at 900 MHz, but sensitivity reaches its maximum around 1.2 GHz. Based on these considerations, a {sup 15}N-detected 2D {sup 1}H–{sup 15}N TROSY-HSQC ({sup 15}N-detected TROSY-HSQC) experiment was developed and high-quality 2D spectra were recorded at 800 MHz in 2 h for 1 mM maltose-binding protein at 278 K (τ{sub c} ∼ 40 ns). Unlike for {sup 1}H detected TROSY, deuteration is not mandatory to benefit {sup 15}N detected TROSY due to reduced dipolar broadening, which facilitates studies of proteins that cannot be deuterated, especially in cases where production requires eukaryotic expression systems. The option of recording {sup 15}N TROSY of proteins expressed in H{sub 2}O media also alleviates the problem of incomplete amide proton back exchange, which often hampers the detection of amide groups in the core of large molecular weight proteins that are expressed in D{sub 2}O culture media and cannot be refolded for amide back exchange. These results illustrate the potential of {sup 15}N{sub H}-detected TROSY experiments as a means to exploit the high resolution offered by high field magnets near and above 1 GHz.

  8. ADX: a high field, high power density, advanced divertor and RF tokamak

    Science.gov (United States)

    LaBombard, B.; Marmar, E.; Irby, J.; Terry, J. L.; Vieira, R.; Wallace, G.; Whyte, D. G.; Wolfe, S.; Wukitch, S.; Baek, S.; Beck, W.; Bonoli, P.; Brunner, D.; Doody, J.; Ellis, R.; Ernst, D.; Fiore, C.; Freidberg, J. P.; Golfinopoulos, T.; Granetz, R.; Greenwald, M.; Hartwig, Z. S.; Hubbard, A.; Hughes, J. W.; Hutchinson, I. H.; Kessel, C.; Kotschenreuther, M.; Leccacorvi, R.; Lin, Y.; Lipschultz, B.; Mahajan, S.; Minervini, J.; Mumgaard, R.; Nygren, R.; Parker, R.; Poli, F.; Porkolab, M.; Reinke, M. L.; Rice, J.; Rognlien, T.; Rowan, W.; Shiraiwa, S.; Terry, D.; Theiler, C.; Titus, P.; Umansky, M.; Valanju, P.; Walk, J.; White, A.; Wilson, J. R.; Wright, G.; Zweben, S. J.

    2015-05-01

    The MIT Plasma Science and Fusion Center and collaborators are proposing a high-performance Advanced Divertor and RF tokamak eXperiment (ADX)—a tokamak specifically designed to address critical gaps in the world fusion research programme on the pathway to next-step devices: fusion nuclear science facility (FNSF), fusion pilot plant (FPP) and/or demonstration power plant (DEMO). This high-field (⩾6.5 T, 1.5 MA), high power density facility (P/S ˜ 1.5 MW m-2) will test innovative divertor ideas, including an ‘X-point target divertor’ concept, at the required performance parameters—reactor-level boundary plasma pressures, magnetic field strengths and parallel heat flux densities entering into the divertor region—while simultaneously producing high-performance core plasma conditions that are prototypical of a reactor: equilibrated and strongly coupled electrons and ions, regimes with low or no torque, and no fuelling from external heating and current drive systems. Equally important, the experimental platform will test innovative concepts for lower hybrid current drive and ion cyclotron range of frequency actuators with the unprecedented ability to deploy launch structures both on the low-magnetic-field side and the high-magnetic-field side—the latter being a location where energetic plasma-material interactions can be controlled and favourable RF wave physics leads to efficient current drive, current profile control, heating and flow drive. This triple combination—advanced divertors, advanced RF actuators, reactor-prototypical core plasma conditions—will enable ADX to explore enhanced core confinement physics, such as made possible by reversed central shear, using only the types of external drive systems that are considered viable for a fusion power plant. Such an integrated demonstration of high-performance core-divertor operation with steady-state sustainment would pave the way towards an attractive pilot plant, as envisioned in the ARC concept

  9. Spontaneous massive hemothorax secondary to chest wall chondrosarcoma: a case report.

    Science.gov (United States)

    Rad, Mohammad Ghasemi; Mahmodlou, Rahim; Mohammadi, Afshin; Mladkova, Nikol; Noorozinia, Farahnaz

    2011-01-01

    We present the case of a 30-year-old man with no past history of disease or recent trauma, who was seen in the emergency room after developing sharp pain in the left hemithorax. Chest roentgenogram showed costopherenic angle blunting and an oval mass in the left mediastinum. A computed tomographic scan showed extrapleural mass with coarse calcifications and pleural effusion, confirmed by magnetic resonance imaging. The tumor was biopsied and removed during thoracotomy. The pathology reported revealed chondrosarcoma, which is a rare cause for a spontaneous massive hemothorax. Invasion of the intercostals vessels by the tumor was the probable cause of hemothorax in this patient.

  10. MAGNET

    CERN Multimedia

    B. Curé

    The first phase of the commissioning ended in August by a triggered fast dump at 3T. All parameters were nominal, and the temperature recovery down to 4.5K was carried out in two days by the cryogenics. In September, series of ramps were achieved up to 3 and finally 3.8T, while checking thoroughly the detectors in the forward region, measuring any movement of and around the HF. After the incident of the LHC accelerator on September 19th, corrective actions could be undertaken in the forward region. When all these displacements were fully characterized and repetitive, with no sign of increments in displacement at each field ramp, it was possible to start the CRAFT, Cosmic Run at Four Tesla (which was in fact at 3.8T). The magnet was ramped up to 18.16kA and the 3 week run went smoothly, with only 4 interruptions: due to the VIP visits on 21st October during the LHC inauguration day; a water leak on the cooling demineralized water circuit, about 1 l/min, that triggered a stop of the cooling pumps, and resulte...

  11. MAGNET

    CERN Multimedia

    Benoit Curé

    The cooling down to the nominal temperature of 4.5 K was achieved at the beginning of August, in conjunction with the completion of the installation work of the connection between the power lines and the coil current leads. The temperature gradient on the first exchanger of the cold box is now kept within the nominal range. A leak of lubricant on a gasket of the helium compressor station installed at the surface was observed and several corrective actions were necessary to bring the situation back to normal. The compressor had to be refilled with lubricant and a regeneration of the filters and adsorbers was necessary. The coil cool down was resumed successfully, and the cryogenics is running since then with all parameters being nominal. Preliminary tests of the 20kA coil power supply were done earlier at full current through the discharge lines into the dump resistors, and with the powering busbars from USC5 to UXC5 without the magnet connected. On Monday evening August 25th, at 8pm, the final commissionin...

  12. MAGNET

    CERN Multimedia

    Benoit Curé

    2013-01-01

    Maintenance work and consolidation activities on the magnet cryogenics and its power distribution are progressing according to the schedules. The manufacturing of the two new helium compressor frame units has started. The frame units support the valves, all the sensors and the compressors with their motors. This activity is subcontracted. The final installation and the commissioning at CERN are scheduled for March–April 2014. The overhauls of existing cryogenics equipment (compressors, motors) are in progress. The reassembly of the components shall start in early 2014. The helium drier, to be installed on the high-pressure helium piping, has been ordered and will be delivered in the first trimester of 2014. The power distribution for the helium compressors in SH5 on the 3.3kV network is progressing. The 3.3kV switches, between each compressor and its hot spare compressor, are being installed, together with the power cables for the new compressors. The 3.3kV electrical switchboards in SE5 will ...

  13. High field transport properties of a bilayer graphene

    Science.gov (United States)

    Bhargavi, K. S.; Kubakaddi, S. S.

    2014-02-01

    The high electric field transport properties namely, hot electron energy loss rate P, momentum loss rate Q, electron temperature Te and drift velocity Vd are studied theoretically in a bilayer graphene (BLG) by employing the momentum and energy balance technique. P and Q are investigated as a function of Te by considering the electron interaction with the acoustic phonons (APs) and the surface polar phonons (SPPs). In the Bloch-Grüneisen regime P (Q) due to APs is ~Te4 (Te2.5), with a new feature of a kink appearing due to the chiral nature of the electrons. The predicted Te4 is consistent with the recent experimental observation of heat resistance (Yan et al. Nature Nanotechnology 3 (2012) 472 [35]). Hot phonon effect is taken into account for SPPs. A dip has been observed in the hot phonon distribution of SPPs, a new feature, which is not found in conventional two-dimensional electron gas, and this can be attributed to the chiral nature of the electrons. P (Q) due to SPPs is found to be dominant at about Te>150 (180) K for a lattice temperature T=4.2 K. It is observed that the hot phonon effect is found to reduce P and Q due to SPPs significantly. Te and Vd are calculated as a function of the electric field E by taking into account the additional channels for momentum relaxation due to Coulomb impurity (CI) and short-range disorder (SD). Te is found to increase with the increasing electric field and is significantly enhanced by the hot phonon effect. Low field Vd is found to be limited by CI, SD and APs and in the high field region it reaches a near saturation value. The hot phonon effect tends to reduce the value of Vd. The presence of disorders CI and SD reduces Vd significantly and in clean samples larger saturation velocity can be achieved at a relatively smaller E.

  14. Primitive chest wall neuroectodermal tumor in a pediatric patient.

    Science.gov (United States)

    Liu, Zhengcheng; Zou, Wei; Ma, Guodong; Pan, Yanqing

    2011-10-01

    A 13-year-old boy with a primitive neuroectodermal tumor of the chest wall is presented. After four cycles of chemotherapy, a computed tomography scan of his chest showed a larger mass invading the left upper lobe of the lung. He underwent resection of the left chest wall from the left fourth to sixth ribs, including the tumor, combined with left upper lobectomy and lymph node dissection. A diagnosis of primitive neuroectodermal tumor was confirmed histopathologically and immunohistochemically. After surgery, four cycles of chemotherapy with ifosfamide and etoposide were given. One year after treatment, the patient is currently doing well without evidence of recurrence.

  15. The effects of chest expansion resistance exercise on chest expansion and maximal respiratory pressure in elderly with inspiratory muscle weakness

    Science.gov (United States)

    Kim, Chang-Beom; Yang, Jin-Mo; Choi, Jong-Duk

    2015-01-01

    [Purpose] The aim of this study was to examine the effect of chest expansion resistance exercises (CERE) on chest expansion, maximal inspiratory pressure (MIP), and maximal expiratory pressure (MEP) in elderly people with inspiratory muscle weakness. [Subjects] Thirty elderly people with inspiratory muscle weakness (MIP < 80% of the predicted value) were randomly and equally assigned to a chest expansion resistance exercise (CERE) group, core conditioning exercise (CCE) group, and control group. [Methods] The intervention was applied to the CERE group and CCE group five times per week, 30 minutes each time, for six weeks. A tapeline was used to measure upper and lower chest expansion. MIP and MEP before and after the intervention were measured and compared. [Results] There was significant improvement in upper and lower chest expansion and MIP after the intervention in both the CERE group and the CCE group, whereas the control group did not show any significant difference. MEP did not significantly change in any of the three groups after the intervention. [Conclusion] The CERE group underwent greater changes than the CCE group, which proves that the CERE is more effective for improving elderly people’s chest expansion capacity and MIP in elderly people. Therefore, application of the CERE by therapists is recommended if the environment and conditions are appropriate for enhancement of chest expansion capacity and MIP in elderly people. PMID:25995570

  16. High-field thermal transports properties of REBCO coated conductors

    CERN Document Server

    Bonura, M

    2015-01-01

    The use of REBCO coated conductors is envisaged for many applications, extending from power cables to high-field magnets. Whatever the case, thermal properties of REBCO tapes play a key role for the stability of superconducting devices. In this work, we present the first study on the longitudinal thermal conductivity (k) of REBCO coated conductors in magnetic fields up to 19 T applied both parallelly and perpendicularly to the thermal-current direction. Copper-stabilized tapes from six industrial manufacturers have been investigated. We show that zero-field k of coated conductors can be calculated with an accuracy of ‡ 15% from the residual resistivity ratio of the stabilizer and the Cu/non-Cu ratio. Measurements performed at high fields have allowed us to evaluate the consistency of the procedures generally used for estimating in-field k in the framework of the Wiedemann-Franz law from an electrical characterization of the materials. In-field data are intended to provide primary ingredients for the ...

  17. Acquisition of High Field Nuclear Magnetic Resonance Spectrometers for Research in Molecular Structure, Function and Dynamics

    Science.gov (United States)

    2011-09-01

    projects may aid in the design of new therapeutic agents to control blood loss and/or wound healing. During the past quarter, further work has...Resonant, Parallel Lm Match 1H ω2(Lm + L) = 1 Ct ωLm = RZ0 In the above, L and Ct are the sample inductor and resonant capacitor, respectively

  18. Prospects for the use of HTS in high field magnets for future accelerator facilities

    CERN Document Server

    Ballarino, A

    2014-01-01

    The enthusiasm that followed discovery of High Temperature Superconductors (HTS) and the initial genuine hope of a replacement technology that could have taken over from conventional Low Temperature Superconductors (LTS) was damped during the years by difficulties in reaching performance levels of competing materials: insufficient current-carrying performance, short piece lengths, and fragility of the brittle oxide superconductors made development of applications slow and limited to demonstrators or devices less demanding from the point of view of conductor performance. However, thanks to a continuous R&D effort, significant progress was made in the past years on the development of cuprate superconductors. Today long lengths of BSCCO 2223 (km range) and REBCO (a more general acronym for YBCO, where RE = Rare Earth) tape (hundreds of meters range) conductor with controlled and homogeneous characteristics are commercially available, and tremendous progress has been made in the development of BSSCO 2212 roun...

  19. Chest trauma: A case for single lung ventilation.

    Science.gov (United States)

    Pandharikar, Nagaraj; Sachdev, Anil; Gupta, Neeraj; Gupta, Suresh; Gupta, Dhiren

    2016-04-01

    Chest trauma is one of the important causes of mortality and morbidity in pediatric trauma patients. The complexity, magnitude, and type of lung injury make it extremely challenging to provide optimal oxygenation and ventilation while protecting the lung from further injury due to mechanical ventilation. Independent lung ventilation is used sporadically in these patients who do not respond to these conventional ventilatory strategies using double-lumen endotracheal tubes, bronchial blocker balloons, etc. However, this equipment may not be easily available in developing countries, especially for pediatric patients. Here, we present a case of severe chest trauma with pulmonary contusion, flail chest, and bronchopleural fistula, who did not respond to conventional lung protective strategies. She was successfully managed with bronchoscopy-guided unilateral placement of conventional endotracheal tube followed by single lung ventilation leading to resolution of a chest injury.

  20. Radiological chest manifestations in diffuse infiltrative lymphocytosis syndrome (DILS

    Directory of Open Access Journals (Sweden)

    F Ismail

    2011-06-01

    Full Text Available This report focuses on the radiological manifestations of diffuse interstitial lymphocytosis syndrome (DILS in the chest. Awareness of this entity and early diagnosis by radiologists will enable timeous intervention by clinicians.

  1. Anterior chest wall involvement in patients with pustulosis palmoplantaris.

    Science.gov (United States)

    Jurik, A G

    1990-01-01

    With the aim of determining the frequency and radiographic features of anterior chest wall involvement in patients with pustulosis palmoplantaris, a questionnaire was sent to 107 patients. Ninety-three patients returned the questionnaire, five of whom were excluded from further analysis due to the appearance of psoriatic lesions. Twenty-five (28%) of the remaining 88 patients reported pain and/or swelling of joints or bones in the anterior chest wall. All were examined radiographically, using tomography, and a group of 20 patients without anterior chest wall complaints were examined similarly. Sixteen of the patients with, but none of the patients without, complaints were found to have arthro-osteitis of the anterior chest wall, consisting of diffuse sclerosis of the manubrium sterni in one patient, localized sclerosis in seven patients, and sequelae of arthritis of the sternoclavicular, upper sternocostal and/or manubriosternal joint in eight patients.

  2. [Clinico-roentgenological semiotics of the chest damage in polytrauma].

    Science.gov (United States)

    Zamiatin, P N; Panchenko, E V; Grigor'ian, G O; Goloshchapova, E V

    2006-10-01

    There are presented the main clinico-roentgenological signs of the chest damage in the injured persons, suffering polytrauma, according to the data from the specialized department of traumatic shock and polytrauma.

  3. Thoracoscopic pulmonary wedge resection without post-operative chest drain

    DEFF Research Database (Denmark)

    Holbek, Bo Laksáfoss; Hansen, Henrik Jessen; Kehlet, Henrik;

    2016-01-01

    effusion and coagulopathy. Chest X-rays were done twice on the day of surgery. 30-day complications were compiled from patient records. RESULTS: 49 patients underwent 51 unilateral VATS wedge resections without using a post-operative chest drain. No patient required reinsertion of a chest drain. 30 (59...... %) patients had a pneumothorax of mean size 12 ± 12 mm on supine 8-h post-operative X-ray for which the majority resolved spontaneously within 2-week control. There were no complications on 30-day follow-up. Median length of stay was 1 day. CONCLUSIONS: The results support that VATS wedge resection...... for pulmonary nodules without a post-operative chest drain may be safe in a selected group of patients....

  4. Chest trauma: A case for single lung ventilation

    Directory of Open Access Journals (Sweden)

    Nagaraj Pandharikar

    2016-01-01

    Full Text Available Chest trauma is one of the important causes of mortality and morbidity in pediatric trauma patients. The complexity, magnitude, and type of lung injury make it extremely challenging to provide optimal oxygenation and ventilation while protecting the lung from further injury due to mechanical ventilation. Independent lung ventilation is used sporadically in these patients who do not respond to these conventional ventilatory strategies using double-lumen endotracheal tubes, bronchial blocker balloons, etc. However, this equipment may not be easily available in developing countries, especially for pediatric patients. Here, we present a case of severe chest trauma with pulmonary contusion, flail chest, and bronchopleural fistula, who did not respond to conventional lung protective strategies. She was successfully managed with bronchoscopy-guided unilateral placement of conventional endotracheal tube followed by single lung ventilation leading to resolution of a chest injury.

  5. Modified Seldinger technique for the insertion of standard chest tubes.

    Science.gov (United States)

    Altman, E; Ben-Nun, A; Curtis, W; Best, L A

    2001-04-01

    Closed tube thoracostomy is a standard procedure for the evacuation of air, blood, or other materials from the pleural space. This paper describes a modification of the Seldinger technique that facilitates chest tube insertion. Either a Nelaton or Thieman catheter is threaded into the side drainage hole and out the tip of a standard Argyle-type chest tube. After using the clamp to insert the catheter into the pleural space through a previously dissected tract, the catheter serves as a guide over which the chest tube is inserted. The technique is simple to use, effective, and safe. It employs standard, inexpensive materials to insert chest tubes in such a way as to minimize the potential traumatic complications inherent in other techniques.

  6. Part Ⅱ The Typical Cases of Chest Pain Syndrome

    Institute of Scientific and Technical Information of China (English)

    Pan Xingfang; Shang Xiaohong

    2001-01-01

    @@ Case 1 Mr Wang, 47 years old. His first visit was on May 7th, 1995. Chief complaints: At the treatment time,chest distress and pain had attacked again and again for six years and worsened for ten days.

  7. Lung and chest wall mechanics in microgravity.

    Science.gov (United States)

    Edyvean, J; Estenne, M; Paiva, M; Engel, L A

    1991-11-01

    We studied the effect of 15-20 s of weightlessness on lung, chest wall, and abdominal mechanics in five normal subjects inside an aircraft flying repeated parabolic trajectories. We measured flow at the mouth, thoracoabdominal and compartmental volume changes, and gastric pressure (Pga). In two subjects, esophageal pressures were measured as well, allowing for estimates of transdiaphragmatic pressure (Pdi). In all subjects functional residual capacity at 0 Gz decreased by 244 +/- 31 ml as a result of the inward displacement of the abdomen. End-expiratory Pga decreased from 6.8 +/- 0.8 cmH2O at 1 Gz to 2.5 +/- 0.3 cmH2O at Gz (P less than 0.005). Abdominal contribution to tidal volume increased from 0.33 +/- 0.05 to 0.51 +/- 0.04 at 0 Gz (P less than 0.001) but delta Pga showed no consistent change. Hence abdominal compliance increased from 43 +/- 9 to 70 +/- 10 ml/cmH2O (P less than 0.05). There was no consistent effect of Gz on tidal swings of Pdi, on pulmonary resistance and dynamic compliance, or on any of the timing parameters determining the temporal pattern of breathing. The results indicate that at 0 G respiratory mechanics are intermediate between those in the upright and supine postures at 1 G. In addition, analysis of end-expiratory pressures suggests that during weightlessness intra-abdominal pressure is zero, the diaphragm is passively tensed, and a residual small pleural pressure gradient may be present.

  8. Pulmonary embolism findings on chest radiographs and multislice spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Coche, Emmanuel; Goncette, Louis [Department of Radiology, Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Verschuren, Franck [Department of Intensive Care and Emergency Medicine, Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Hainaut, Philippe [Department of Internal Medicine, Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium)

    2004-07-01

    Multislice spiral CT is becoming an increasingly important tool for diagnosing pulmonary embolism. However, in many instances, a chest radiograph is usually performed as a first-line examination. Many parenchymal, vascular, and other ancillary findings may be observed on both imaging modalities with a highly detailed depiction of abnormalities on multislice CT. A comprehensive review of chest radiograph findings is presented with side-by-side correlations of CT images reformatted mainly in the frontal plane. (orig.)

  9. Pulmonary embolism findings on chest radiographs and multislice spiral CT.

    Science.gov (United States)

    Coche, Emmanuel; Verschuren, Franck; Hainaut, Philippe; Goncette, Louis

    2004-07-01

    Multislice spiral CT is becoming an increasingly important tool for diagnosing pulmonary embolism. However, in many instances, a chest radiograph is usually performed as a first-line examination. Many parenchymal, vascular, and other ancillary findings may be observed on both imaging modalities with a highly detailed depiction of abnormalities on multislice CT. A comprehensive review of chest radiograph findings is presented with side-by-side correlations of CT images reformatted mainly in the frontal plane.

  10. Comparison of Fentanyl with Sufentanil for Chest Tube Removal

    Directory of Open Access Journals (Sweden)

    M Golmohammadi

    2008-11-01

    Full Text Available Background: After cardiac surgery, the chest tubes cause pain and their removal is painful and unpleasant forpatients. The aim of this research was to study and compare the analgesic effect of fentanyl and sufentanil on painrelief during chest tube removal in post-cardiac surgical patients.Patients and Methods: A total of 80 patients scheduled for elective cardiac surgery, were recruited in prospective,randomized and double-blind study. Patients received 1.5μg/kg fentanyl or 0.15μg/kg sufentanyl, intravenously10 minutes before removal of chest tube. Pain intensity was assessed by measuring visual analogscale (VAS pain score, 10 minutes before, during, and 5 and10 minutes after removing chest tubes. Level ofsedation, heart rate, arterial blood pressure, and oxygenation saturation were recorded at each stage by a blindedobserver.Results: Mean pain intensity scores 10 minutes before removal of chest tube in fentanyl, and sufentanil groupswere 29.5±12.1 and 31±11.2 respectively. Pain scores during chest tube removal were 38.5±11.6 in fentanylgroup and 44.7±12.8 in sufentanil group (P =0.02. In addition, pain scores during chest tube removal were significantly(P value=0.02 more reduced in fentanyl (17.21±7.5 than in sufentanil group (21.51±11.2. Sedationscores remained low in two groups. None of the patients showed any adverse side effects of opioids. No differenceswere seen in the heart rate or arterial blood pressure, but oxygenation saturation was significantly greaterin sufentanil group than in fentanyl group.Conclusion: Both fentanyl and sufentanil provide adequate analgesia for chest tube removal without increasinguntoward side effects.

  11. Young Woman with a Fever and Chest Pain

    Directory of Open Access Journals (Sweden)

    Kristin H. Dwyer, MD, MPH

    2016-03-01

    Full Text Available A 26-year-old female presented to the emergency department with three days of subjective fevers, dry cough and pleuritic chest discomfort. On exam, her vital signs were significant for a heart rate of 106/minute and oxygen saturation of 95% on room air. Her lung exam revealed decreased breath sounds at the right base. A bedside lung ultrasound and a chest radiograph were performed (Figure 1a, Figure 2, and Video.

  12. High-Frequency Chest Compression: A Summary of the Literature

    OpenAIRE

    Dosman, Cara F; Jones, Richard L

    2005-01-01

    The purpose of the present literature summary is to describe high-frequency chest compression (HFCC), summarize its history and outline study results on its effect on mucolysis, mucus transport, pulmonary function and quality of life. HFCC is a mechanical method of self-administered chest physiotherapy, which induces rapid air movement in and out of the lungs. This mean oscillated volume is an effective method of mucolysis and mucus clearance. HFCC can increase independence. Some studies have...

  13. Chest Pain Units: A Modern Way of Managing Patients with Chest Pain in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Roberto Bassan

    2002-08-01

    Full Text Available It is estimated that 5 to 8 million individuals with chest pain or other symptoms suggestive of myocardial ischemia are seen each year in emergency departments (ED in the United States 1,2, which corresponds to 5 to 10% of all visits 3,4. Most of these patients are hospitalized for evaluation of possible acute coronary syndrome (ACS. This generates an estimated cost of 3 - 6 thousand dollars per patient 5,6. From this evaluation process, about 1.2 million patients receive the diagnosis of acute myocardial infarction (AMI, and just about the same number have unstable angina. Therefore, about one half to two thirds of these patients with chest pain do not have a cardiac cause for their symptoms 2,3. Thus, the emergency physician is faced with the difficult challenge of identifying those with ACS - a life-threatening disease - to treat them properly, and to discharge the others to suitable outpatient investigation and management.

  14. Comparison of expectorated sputum after manual chest physical therapy and high-frequency chest compression.

    Science.gov (United States)

    Warwick, Warren J; Wielinski, Catherine L; Hansen, Leland G

    2004-01-01

    This study is a quantitative comparison of the sputum produced by 12 subjects with cystic fibrosis (CF) who received high-frequency chest compression (HFCC) and standard chest physical therapy (CPT) in randomized order. Six subjects routinely used manual CPT and six routinely used the HFCC. None had acute infections or hospitalization in the six weeks before the study. Two certified respiratory therapists alternated subjects and CPT vs HFCC order during the two weeks of the matched study. For all sessions, the expectorated sputum was collected in preweighed cups, which were reweighed immediately after collection and again after evaporation to dryness. The wet and dry weights of the sputum produced as a result of the two techniques were significantly different, with HFCC having greater weight. Regardless of the mode of therapy, the sputum produced by the subjects who regularly received HFCC had greater water content than did the sputum produced by those subjects who regularly received CPT. No significant difference was found between the two therapists regarding sputum expectorated by the subjects during CPT. These results show that sputum production by subjects with CF who receive CPT by certified respiratory therapists can be as great as the sputum produced by the same subjects who receive HFCC. The results also suggest that unknown factors attributed to the therapists may produce different levels of effort from time to time that may decrease the respiratory therapists' effectiveness, whereas the HFCC therapy may be more consistently effective because it is entirely machine based.

  15. Acquisition and analysis strategies in functional MRI at high fields

    CERN Document Server

    Windischberger, C

    2001-01-01

    Functional magnetic resonance imaging represents a non-invasive technique to examine neuronal activity in the brain. It applies radio waves to excite nuclear spins, using the emitted signal during relaxation for image generation. Signal modulations from local blood flow and oxygenation level changes caused by neuronal activity are the basis for calculating functional brain maps with high spatial resolution. The present work discusses concepts for improving the spatial and temporal resolution, as well as sophisticated analysis approaches. Besides an exhaustive description of image reconstruction algorithms, computational simulations on echo-shifting in echo-planar imaging are presented and effects on spatial resolution are quantified. The results demonstrate that echo-shifting causes only minimal resolution losses for high signal-to-noise data, but leads to severe resolution degradation (up to 30 %) in images with low signal-to-noise ratios. After an overview of the mechanisms that cause fMRI signal changes su...

  16. Simultaneous EEG-fMRI at ultra-high field: artifact prevention and safety assessment.

    Science.gov (United States)

    Jorge, João; Grouiller, Frédéric; Ipek, Özlem; Stoermer, Robert; Michel, Christoph M; Figueiredo, Patrícia; van der Zwaag, Wietske; Gruetter, Rolf

    2015-01-15

    The simultaneous recording of scalp electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) can provide unique insights into the dynamics of human brain function, and the increased functional sensitivity offered by ultra-high field fMRI opens exciting perspectives for the future of this multimodal approach. However, simultaneous recordings are susceptible to various types of artifacts, many of which scale with magnetic field strength and can seriously compromise both EEG and fMRI data quality in recordings above 3T. The aim of the present study was to implement and characterize an optimized setup for simultaneous EEG-fMRI in humans at 7 T. The effects of EEG cable length and geometry for signal transmission between the cap and amplifiers were assessed in a phantom model, with specific attention to noise contributions from the MR scanner coldheads. Cable shortening (down to 12 cm from cap to amplifiers) and bundling effectively reduced environment noise by up to 84% in average power and 91% in inter-channel power variability. Subject safety was assessed and confirmed via numerical simulations of RF power distribution and temperature measurements on a phantom model, building on the limited existing literature at ultra-high field. MRI data degradation effects due to the EEG system were characterized via B0 and B1(+) field mapping on a human volunteer, demonstrating important, although not prohibitive, B1 disruption effects. With the optimized setup, simultaneous EEG-fMRI acquisitions were performed on 5 healthy volunteers undergoing two visual paradigms: an eyes-open/eyes-closed task, and a visual evoked potential (VEP) paradigm using reversing-checkerboard stimulation. EEG data exhibited clear occipital alpha modulation and average VEPs, respectively, with concomitant BOLD signal changes. On a single-trial level, alpha power variations could be observed with relative confidence on all trials; VEP detection was more limited, although

  17. Chest wall segmentation in automated 3D breast ultrasound scans.

    Science.gov (United States)

    Tan, Tao; Platel, Bram; Mann, Ritse M; Huisman, Henkjan; Karssemeijer, Nico

    2013-12-01

    In this paper, we present an automatic method to segment the chest wall in automated 3D breast ultrasound images. Determining the location of the chest wall in automated 3D breast ultrasound images is necessary in computer-aided detection systems to remove automatically detected cancer candidates beyond the chest wall and it can be of great help for inter- and intra-modal image registration. We show that the visible part of the chest wall in an automated 3D breast ultrasound image can be accurately modeled by a cylinder. We fit the surface of our cylinder model to a set of automatically detected rib-surface points. The detection of the rib-surface points is done by a classifier using features representing local image intensity patterns and presence of rib shadows. Due to attenuation of the ultrasound signal, a clear shadow is visible behind the ribs. Evaluation of our segmentation method is done by computing the distance of manually annotated rib points to the surface of the automatically detected chest wall. We examined the performance on images obtained with the two most common 3D breast ultrasound devices in the market. In a dataset of 142 images, the average mean distance of the annotated points to the segmented chest wall was 5.59 ± 3.08 mm.

  18. A new specifically designed forceps for chest drain insertion.

    LENUS (Irish Health Repository)

    Andrews, Emmet

    2012-02-03

    Insertion of a chest drain can be associated with serious complications. It is recommended that the drain is inserted with blunt dissection through the chest wall but there is no specific instrument to aid this task. We describe a new reusable forceps that has been designed specifically to facilitate the insertion of chest drains.A feasibility study of its use in patients who required a chest drain as part of elective cardiothoracic operations was undertaken. The primary end-point was successful and accurate placement of the drain. The operators also completed a questionnaire rating defined aspects of the procedure. The new instrument was used to insert the chest drain in 30 patients (19 male, 11 female; median age 61.5 years (range 16-81 years)). The drain was inserted successfully without the trocar in all cases and there were no complications. Use of the instrument rated as significantly easier relative to experience of previous techniques in all specified aspects. The new device can be used to insert intercostal chest drains safely and efficiently without using the trocar or any other instrument.

  19. COMBINED EFFECT OF PNF STRETCHING WITH CHEST MOBILITY EXERCISES ON CHEST EXPANSION AND PULMONARY FUNCTIONS FOR ELDERLY

    Directory of Open Access Journals (Sweden)

    Vinod Babu .K

    2015-06-01

    Full Text Available Background: PNF stretching and chest mobility exercises found to be effective in elder patients, however the combined effectiveness of these techniques were unknown. The purpose of this study is to find the effect of Hold-relax PNF stretching technique for pectoralis muscle combined with chest mobility exercises on improvement of chest expansion and pulmonary function for elderly subjects. Method: An Experimental study design, 30 subjects with age group above 60 years were randomized 15 subjects each into Study and Control group. Control group received Supervised Active Assisted Exercise Program while Study group received Hold-relax PNF Stretching for pectoralis muscle, Chest Mobility Exercises Program and supervised Active Assisted Exercise Program for a period of one week. Outcome measures such as chest expansion at axilla and xiphisternum and pulmonary function test such as FEV1, FVC and FEV1/FVC were measured before and after one week of treatment. Results: Analysis using paired ‘t’ test within the group found that there is no statistically significant difference within control group where as there is a statistical significant difference within study group. Comparative analysis of pre-intervention means shown that there is no statistically significant difference between the groups. Comparative analysis of post-intervention means shown that there is a statistically significant difference in means of Chest expansion, FEV1/FVC and there is no statistical significant difference in FEV1 and FVC between study and control groups. Conclusion: It is concluded that one week of combined Hold-relax PNF stretching for pectoralis muscle with chest mobility exercises shown significant improvement in chest expansion and pulmonary function test such as forced expiratory volume and forced vital capacity than only active assisted exercise program for elderly subjects.

  20. Posterior diaphragmatic defect detected on chest CT: the incidence according to age and the lateral chest radiographic appearances

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Son Youl; Choi, Yo Won; Jeon, Seok Chol; Heo, Jeong Nam; Park, Choong Ki [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    2007-03-15

    We wanted to investigate the incidence of posterior diaphragmatic defect on chest CT in various age groups and its lateral chest radiographic appearances. The chest CT scans of 78 patients of various ages with posterior diaphragmatic defect were selected among 1,991 patients, and they were analyzed for the incidence of defect in various age groups, the defect location and the herniated contents. Their lateral chest radiographs were analyzed for the shape of the posterior diaphragm and the posterior costophrenic sulcus. The patients' ages ranged from 34 to 87 with the tendency of a higher incidence in the older patients. The defect most frequently involved the medial two thirds (n = 49, 50.4%) and middle one third (n = 36, 37%) of the posterior diaphragm. The retroperitoneal fat was herniated into the thorax through the defect in all patients, and sometimes with the kidney (n = 8). Lateral chest radiography showed a normal diaphragmatic contour (n = 51, 49.5%), blunting of the posterior costophrenic sulcus (n = 41, 39.8%), focal humping of the posterior diaphragm (n = 7, 6.8%), or upward convexity (n = 4, 3.9%) of the posterior costophrenic sulcus on the affected side. The posterior diaphragmatic defect discovered in asymptomatic patients who are without a history of peridiaphragmatic disease is most likely acquired, and this malady increases in incidence according to age. An abnormal contour of the posterior diaphragm or the costophrenic sulcus on a lateral chest radiograph may be a finding of posterior diaphragmatic defect.

  1. [Chest pain - not always the heart! Clinical impact of gastrointestinal diseases in non-cardiac chest pain].

    Science.gov (United States)

    Frieling, T; Bergdoldt, G; Allescher, H D; Riemann, J F

    2015-02-01

    Non cardiac chest pain (NCCP) are recurrent angina pectoris like pain without evidence of coronary heart disease in conventional diagnostic evaluation. The prevalence of NCCP is up to 70 % and may be detected in this order at all levels of the medical health care system (general practitioner, emergency department, chest pain unit, coronary care). Reduction of quality of life in NCCP is comparable, partially even higher compared to cardiac chest pain. Reasons for psychological strain are symptom recurrence in app. 50 %, nonspecific diagnosis with resulting uncertainty and insufficient integration of other medical disciplines in diagnostic work-up. Managing of patients with NCCP has to be interdisciplinary because non cardiac causes of chest pain may be found frequently. Especially gastroenterological expertise is required because in 50 - 60 % of cases gastroesophageal reflux disease (GERD), in 15 - 18 % hypercontractile esophageal motility disorders with nutcracker, jackhammer esophagus or distal esophageal spasmus or achalasia and in 32 - 35 % other esophageal alterations (e. g. infectious esophageal inflammation, drug-induced ulcer, rings, webs, eosinophilic esophagitis) as cause of chest pain may be detected. This implicates that regular interdisciplinary round wards and management of chest pain units are mandatory.

  2. High-field studies of quantum oscillations in quasi-two-dimensional organic metals

    Science.gov (United States)

    Sandhu, Pravindrajit

    The organic metals derived from the molecule BEDT-TTF (or ET for short) are important as model systems for the study of low-dimensional phenomena. These materials are molecular crystals with a low Fermi energy (10--100 meV), high mobility (˜104 cm2/Vs) and highly anisotropic Fermi surfaces. We have conducted experimental studies of ( i) the Shubnikov-de Haas (SdH) effect in pulsed fields up to 50 T and (ii) the de Haas-van Alphen (dHvA) effect in steady fields up to 33 T on alpha - (ET)2 MHg(SCN) 4 (where M = K, Tl and NH4) and kappa - (ET)2 Cu (NCS)2. At these high fields, the wave shape as well as the temperature and field-dependence of the oscillations deviate from the behavior predicted by the standard Lifshitz-Kosevich theory. These measurements reveal the limits of the conventional theory of metals and lay the ground-work for extending the theory to low-dimensional systems. We have also performed extended Huckel tight-binding calculations to model the effects of pressure and uniaxial stress on the electronic band structure of kappa - (ET)2 KHg (SCN)4 and kappa - (ET)2 Cu (NCS)2. The calculated changes in the Fermi surface topology are in excellent agreement with the experimental values determined from SdH measurements. We also report predictions of the effects of uniaxial stress in the transverse directions and discuss the behavior of the effective mass and magnetic breakdown probability. Finally, we have investigated the origin of anomalous magnetic breakdown frequencies in the dHvA effect that are forbidden according to semi-classical theories. We construct a tight-binding model based on the realistic band-structure of the system, which is then solved numerically to compute the field-dependence of the magnetization. This model provides a natural description for the phenomenon of magnetic breakdown between co-existing closed and open Fermi surfaces and accounts for the anomalous frequencies that are observed experimentally. The occurrence of these

  3. High-Field MRI and Mercury Release from Dental Amalgam Fillings

    Directory of Open Access Journals (Sweden)

    SMJ Mortazavi

    2014-04-01

    Full Text Available Mercury is among the most toxic nonradioactive elements which may cause toxicity even at low doses. Some studies showed release of mercury from dental amalgam fillings in individuals who used mobile phone. This study was conducted to assess the effect of high-field MRI on mercury release from dental amalgam filling. We studied two groups of students with identical tooth decays requiring a similar pattern of restorative dentistry. They were exposed to a magnetic flux density of 1.5 T produced by a MRI machine. 16 otherwise healthy students with identical dental decay participated in this study. They underwent similar restorative dentistry procedures and randomly divided into two groups of MRI-exposed and control arms. Urinary concentrations of mercury in the control subjects were measured before (hour 0 and 48 and 72 hrs after amalgam restoration, using cold vapor atomic absorption spectrometry. Urinary concentrations of mercury in exposed individuals were determined before (hour 0, and 24, 48, 72 and 96 hrs after amalgam restoration. Unlike control subjects, they underwent conventional brain MRI (15 min, 99 slices, 24 hrs after amalgam restoration. The mean±SD urinary mercury levels in MRI-exposed individuals increased linearly from a baseline value of 20.70±17.96 to 24.83±22.91 μg/L 72 hrs after MRI. In the control group, the concentration decreased linearly from 20.70±19.77 to 16.14±20.05 μg/L. The difference between urinary mercury in the exposed and control group, 72 hrs after MRI (96 h after restoration,was significant (p=0.046. These findings provide further support for the noxious effect of MRI (exposure to strong magnetic fieldand release of mercury from dental amalgam fillings.

  4. High-field MRI and mercury release from dental amalgam fillings.

    Science.gov (United States)

    Mortazavi, S M J; Neghab, M; Anoosheh, S M H; Bahaeddini, N; Mortazavi, G; Neghab, P; Rajaeifard, A

    2014-04-01

    Mercury is among the most toxic nonradioactive elements which may cause toxicity even at low doses. Some studies showed release of mercury from dental amalgam fillings in individuals who used mobile phone. This study was conducted to assess the effect of high-field MRI on mercury release from dental amalgam filling. We studied two groups of students with identical tooth decays requiring a similar pattern of restorative dentistry. They were exposed to a magnetic flux density of 1.5 T produced by a MRI machine. 16 otherwise healthy students with identical dental decay participated in this study. They underwent similar restorative dentistry procedures and randomly divided into two groups of MRI-exposed and control arms. Urinary concentrations of mercury in the control subjects were measured before (hour 0) and 48 and 72 hrs after amalgam restoration, using cold vapor atomic absorption spectrometry. Urinary concentrations of mercury in exposed individuals were determined before (hour 0), and 24, 48, 72 and 96 hrs after amalgam restoration. Unlike control subjects, they underwent conventional brain MRI (15 min, 99 slices), 24 hrs after amalgam restoration. The mean±SD urinary mercury levels in MRI-exposed individuals increased linearly from a baseline value of 20.70±17.96 to 24.83±22.91 μg/L 72 hrs after MRI. In the control group, the concentration decreased linearly from 20.70±19.77 to 16.14±20.05 μg/L. The difference between urinary mercury in the exposed and control group, 72 hrs after MRI (96 h after restoration),was significant (p=0.046). These findings provide further support for the noxious effect of MRI (exposure to strong magnetic field)and release of mercury from dental amalgam fillings.

  5. Intermediate length scale organisation in tin borophosphate glasses: new insights from high field correlation NMR.

    Science.gov (United States)

    Tricot, G; Saitoh, A; Takebe, H

    2015-11-28

    The structure of tin borophosphate glasses, considered for the development of low temperature sealing glasses or anode materials for Li-batteries, has been analysed at the intermediate length scale by a combination of high field standard and advanced 1D/2D nuclear magnetic resonance techniques. The nature and extent of B/P mixing were analysed using the (11)B((31)P) dipolar heteronuclear multiple quantum coherence NMR sequence and the data interpretation allowed (i) detecting the presence and analysing the nature of the B-O-P linkages, (ii) re-interpreting the 1D (31)P spectra and (iii) extracting the proportion of P connected to borate species. Interaction between the different borate species was analysed using the (11)B double quantum-simple quantum experiment to (i) investigate the presence and nature of the B-O-B linkage, (ii) assign the different borate species observed all along the composition line and (iii) monitor the borate network formation. In addition, (119)Sn static NMR was used to investigate the evolution of the chemical environment of the tin polyhedra. Altogether, the set of data allowed determining the structural units constituting the glass network and quantifying the extent of B/P mixing. The structural data were then used to explain the non-linear and unusual evolution of the glass transition temperature.

  6. Spin dynamics of S = 1/2 kagome lattice antiferromagnets observed by high-field ESR

    Energy Technology Data Exchange (ETDEWEB)

    Ohta, Hitoshi [Molecular Photoscience Research Center, Kobe University, Kobe 657-8501 (Japan); Graduate School of Science, Kobe University, Kobe 657-8501 (Japan); Zhang, Wei-min [Graduate School of Science, Kobe University, Kobe 657-8501 (Japan); Okubo, Susumu; Fujisawa, Masashi [Molecular Photoscience Research Center, Kobe University, Kobe 657-8501 (Japan); Sakurai, Takahiro [Center for Supports to Research and Education Activities, Kobe University, Kobe 657-8501 (Japan); Okamoto, Yoshihiko; Yoshida, Hiroyuki; Hiroi, Zenji [Institute for Solid State Physics (ISSP), University of Tokyo, Kashiwa, Chiba 277-8581 (Japan)

    2010-03-15

    Due to the existence of strong spin frustration in a system, the spin dynamics of S = 1/2 kagome lattice antiferromagnet at low temperature has attracted much interest. High-field ESR has been measured on its model substances, Cu{sub 3}V{sub 2}O{sub 7}(OH){sub 2} . 2H{sub 2}O (volborthite) and BaCu{sub 3}V{sub 2}O{sub 3}(OH){sub 2} (vesignieite), down to 1.8 K using pulsed magnetic fields up to 16 T. The measurements are performed for 160 and 315 GHz using polycrys-talline samples. Although both samples showed the g-shift and the change of linewidth at low temperature, volborthite showed a small gap excitation of the order of 40 GHz (1.9 K) while vesignieite showed a paramagnetic behavior down to 1.9 K. Observed difference will be discussed in connection with the crystal structure, and the possible spin liquid state in vesignieite will be discussed. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  7. Effects of anesthetic agents on brain blood oxygenation level revealed with ultra-high field MRI.

    Directory of Open Access Journals (Sweden)

    Luisa Ciobanu

    Full Text Available During general anesthesia it is crucial to control systemic hemodynamics and oxygenation levels. However, anesthetic agents can affect cerebral hemodynamics and metabolism in a drug-dependent manner, while systemic hemodynamics is stable. Brain-wide monitoring of this effect remains highly challenging. Because T(2*-weighted imaging at ultra-high magnetic field strengths benefits from a dramatic increase in contrast to noise ratio, we hypothesized that it could monitor anesthesia effects on brain blood oxygenation. We scanned rat brains at 7T and 17.2T under general anesthesia using different anesthetics (isoflurane, ketamine-xylazine, medetomidine. We showed that the brain/vessels contrast in T(2*-weighted images at 17.2T varied directly according to the applied pharmacological anesthetic agent, a phenomenon that was visible, but to a much smaller extent at 7T. This variation is in agreement with the mechanism of action of these agents. These data demonstrate that preclinical ultra-high field MRI can monitor the effects of a given drug on brain blood oxygenation level in the absence of systemic blood oxygenation changes and of any neural stimulation.

  8. Methane storage in nanoporous media as observed via high field NMR relaxometry

    CERN Document Server

    Papaioannou, Antonios

    2015-01-01

    The storage properties of methane gas in Vycor porous glass (5.7 nm) are characterized in a wide pressure range from 0.7 MPa-89.7 MPa using Nuclear Magnetic Resonance (NMR). We demonstrate the capability of high field NMR relaxometry for the determination of the methane gas storage capacity and the measurement of the Hydrogen Index, to a high degree of accuracy. This helps determine the excess gas in the pore space which can be identified to exhibit Langmuir properties in the low pressure regime of 0.7 MPa to 39.6 Mpa. The Langmuir model enables us to determine the equilibrium density of the monolayer of adsorbed gas to be 8.5% lower than that of liquid methane. We also identify the signatures of multilayer adsorption at the high pressure regime from 39.6 Mpa to 89.7 Mpa and use the Brunauer-Emmet-Teller (BET) theory to determine the number of adsorbed layers of methane gas. We show how these measurements help us differentiate the gas stored in the Vycor pore space into free and adsorbed fractions for the ent...

  9. Comparison of chest radiography, chest digital tomosynthesis and low dose MDCT to detect small ground-glass opacity nodules: an anthropomorphic chest phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Doo, Kyung Won; Kang, Eun-Young; Yong, Hwan Seok [Korea University Guro Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Ham, Soo-Youn [Korea University Anam Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Lee, Ki Yeol; Choo, Ji Yung [Korea University Ansan Hospital, Korea University College of Medicine, Department of Radiology, Ansan (Korea, Republic of)

    2014-12-15

    The purpose of this study was to evaluate the diagnostic performance of chest radiography (CXR), chest digital tomosynthesis (DT) and low dose multidetector computed tomography (LDCT) for the detection of small pulmonary ground-glass opacity (GGO) nodules, using an anthropomorphic chest phantom. Artificial pulmonary nodules were placed in a phantom and a total of 40 samples of different nodule settings underwent CXR, DT and LDCT. The images were randomly read by three experienced chest radiologists. Free-response receiver-operating characteristics (FROC) were used. The figures of merit for the FROC curves averaged for the three observers were 0.41, 0.37 and 0.76 for CXR, DT and LDCT, respectively. FROC analyses revealed significantly better performance of LDCT over CXR or DT for the detection of GGO nodules (P < 0.05). The difference in detectability between CXR and DT was not statistically significant (P = 0.73). The diagnostic performance of DT for the detection of pulmonary small GGO nodules was not significantly different from that of CXR, but LDCT performed significantly better than both CXR and DT. DT is not a suitable alternative to CT for small GGO nodule detection, and LDCT remains the method of choice for this purpose. (orig.)

  10. Chest wall syndrome among primary care patients: a cohort study

    Directory of Open Access Journals (Sweden)

    Verdon François

    2007-09-01

    Full Text Available Abstract Background The epidemiology of chest pain differs strongly between outpatient and emergency settings. In general practice, the most frequent cause is the chest wall pain. However, there is a lack of information about the characteristics of this syndrome. The aims of the study are to describe the clinical aspects of chest wall syndrome (CWS. Methods Prospective, observational, cohort study of patients attending 58 private practices over a five-week period from March to May 2001 with undifferentiated chest pain. During a one-year follow-up, questionnaires including detailed history and physical exam, were filled out at initial consultation, 3 and 12 months. The outcomes were: clinical characteristics associated with the CWS diagnosis and clinical evolution of the syndrome. Results Among 24 620 consultations, we observed 672 cases of chest pain and 300 (44.6% patients had a diagnosis of chest wall syndrome. It affected all ages with a sex ratio of 1:1. History and sensibility to palpation were the keys for diagnosis. Pain was generally moderate, well localised, continuous or intermittent over a number of hours to days or weeks, and amplified by position or movement. The pain however, may be acute. Eighty-eight patients were affected at several painful sites, and 210 patients at a single site, most frequently in the midline or a left-sided site. Pain was a cause of anxiety and cardiac concern, especially when acute. CWS coexisted with coronary disease in 19 and neoplasm in 6. Outcome at one year was favourable even though CWS recurred in half of patients. Conclusion CWS is common and benign, but leads to anxiety and recurred frequently. Because the majority of chest wall pain is left-sided, the possibility of coexistence with coronary disease needs careful consideration.

  11. Pleural controversy: optimal chest tube size for drainage.

    Science.gov (United States)

    Light, Richard W

    2011-02-01

    In recent years, a higher and higher percentage of patients with pleural effusions or pneumothorax are being treated with small-bore (10-14 F) chest tubes rather than large-bore (>20 F). However, there are very few randomized controlled studies comparing the efficacy and complication rates with the small- and large-bore catheters. Moreover, the randomized trials that are available have flaws in their design. The advantages of the small-bore catheters are that they are easier to insert and there is less pain with their insertion while they are in place. The placement of the small-bore catheters is probably more optimal when placement is done with ultrasound guidance. Small-bore chest tubes are recommended when pleurodesis is performed. The success of the small-bore indwelling tunnelled catheters that are left in place for weeks documents that the small-bore tubes do not commonly become obstructed with fibrin. Patients with complicated parapneumonic effusions are probably best managed with small-bore catheters even when the pleural fluid is purulent. Patients with haemothorax are best managed with large-bore catheters because of blood clots and the high volume of pleural fluid. Most patients with pneumothorax can be managed with aspiration or small-bore chest tubes. If these fail, a large-bore chest tube may be necessary. Patients on mechanical ventilation with barotrauma induced pneumothoraces are best managed with large-bore chest tubes.

  12. Chest X-ray imaging of patients with SARS

    Institute of Scientific and Technical Information of China (English)

    陆普选; 周伯平; 陈心春; 袁明远; 龚小龙; 杨根东; 刘锦清; 袁本通; 郑广平; 杨桂林; 王火生

    2003-01-01

    Objective To investigate the chest X-ray manifestations of SARS cases.Methods A retrospective study was conducted among 52 clinically confirmed SARS patients from February 9 to May 10, 2003. Chest X-ray scanning was performed at a interval of 1-3 days according to the requirements. The manifestations and special features of SARS in X-ray were analyzed. Results Small or large patchy shadows with intensive density in both lungs were observed in 31 cases, ground-glass like opacification in 16, small patchy shadows in one lung lobe or one lung segment in 18, nodular shadows in one lung segment in 1, and increased lung marking in lung interstitial tissues in 2. Rapidly changing consolidations revealed in chest X-ray images were found to be associated with SARS infections, and they were not affected by treatment with antibiotics.Conclusion Chest X-ray provides a sensitive and specific method for the diagnosis and treatment of SARS, and those present with symptoms and signs should undergo chest X-ray scanning every 1-3 days.

  13. Factors Associated with ICU Admission following Blunt Chest Trauma

    Directory of Open Access Journals (Sweden)

    Andrea Bellone

    2016-01-01

    Full Text Available Background. Blunt chest wall trauma accounts for over 10% of all trauma patients presenting to emergency departments worldwide. When the injury is not as severe, deciding which blunt chest wall trauma patients require a higher level of clinical input can be difficult. We hypothesized that patient factors, injury patterns, analgesia, postural condition, and positive airway pressure influence outcomes. Methods. The study population consisted of patients hospitalized with at least 3 rib fractures (RF and at least one pulmonary contusion and/or at least one pneumothorax lower than 2 cm. Results. A total of 140 patients were retrospectively analyzed. Ten patients (7.1% were admitted to intensive care unit (ICU within the first 72 hours, because of deterioration of the clinical conditions and gas exchange with worsening of chest X-ray/thoracic ultrasound/chest computed tomography. On univariable analysis and multivariable analysis, obliged orthopnea (p=0.0018 and the severity of trauma score (p<0.0002 were associated with admission to ICU. Conclusions. Obliged orthopnea was an independent predictor of ICU admission among patients incurring non-life-threatening blunt chest wall trauma. The main therapeutic approach associated with improved outcome is the prevention of pulmonary infections due to reduced tidal volume, namely, upright postural condition and positive airway pressure.

  14. CT chest under general anesthesia: pulmonary, anesthetic and radiologic dilemmas

    Energy Technology Data Exchange (ETDEWEB)

    Mahmoud, Mohamed [Cincinnati Children' s Hospital Medical Center, Department of Anesthesiology, Cincinnati, OH (United States); Towe, Christopher [Cincinnati Children' s Hospital Medical Center, Department of Pulmonary Medicine, Cincinnati, OH (United States); Fleck, Robert J. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2015-07-15

    Today's practice of medicine involves ever more complex patients whose care is coordinated with multidisciplinary teams. Caring for these patients can challenge all members of the health care team. Sedation/anesthesia in infants/toddlers as well as uncooperative or intellectually or emotionally impaired children who require imaging studies of the chest are ongoing challenges. High-quality computed tomography (CT) chest imaging studies in children under general anesthesia are extremely important for accurate interpretation and subsequent medical decision-making. Anesthesia-induced atelectasis may obscure or mimic true pathology creating a significant quality issue. Obtaining a high-quality, motion-free chest imaging study in infants and children under general anesthesia remains a difficult task in many institutions. Meticulous attention to anesthesia and imaging techniques and specialized knowledge are required to properly perform and interpret chest imaging studies. In this commentary, we discuss the continuous struggle to obtain high-quality CT chest imaging under general anesthesia. We will also discuss the major concerns of the anesthesiologist, radiologist and pulmonologist and why cooperation and coordination among these providers are critical for an optimal quality study.

  15. Chest physiotherapy in children with acute bacterial pneumonia

    Directory of Open Access Journals (Sweden)

    Lieselotte Corten

    2015-04-01

    Full Text Available Background: Pneumonia is the single leading cause of death in children younger than 5 years of age. Chest physiotherapy is often prescribed as an additional therapy in children with pneumonia. Different chest physiotherapy techniques are available that aim to improve airway clearance, gas exchange and reduce the work of breathing. However, it is unclear if these techniques are effective in this population.Objective: The present review aimed to determine the efficacy of different chest physiotherapy techniques compared with no physiotherapy or other chest physiotherapy treatments in hospitalised children with bacterial pneumonia.Method: Six electronic databases (PubMed, Medline, Cochrane Library, PEDro, CINAHL and Africa-wide information, clinicaltrials.gov and pactr.org were searched for eligible studies.Results: Two randomised controlled trials and one ongoing study were identified. Neither completed trial reported differences between the control and intervention groups, although one study reported a longer duration of coughing (p = 0.04 and rhonchi (p = 0.03 in the intervention group.Conclusion: Because of the limited number of included articles and different presentations of outcome measures, we could not reject or accept chest physiotherapy as either an effective or harmful treatment option in this population.

  16. Computer-aided diagnosis in chest radiography: Beyond nodules

    Energy Technology Data Exchange (ETDEWEB)

    Ginneken, Bram van [University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands)], E-mail: bram@isi.uu.nl; Hogeweg, Laurens; Prokop, Mathias [University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

    2009-11-15

    Chest radiographs are the most common exam in radiology. They are essential for the management of various diseases associated with high mortality and morbidity and display a wide range of findings, many of them subtle. In this survey we identify a number of areas beyond pulmonary nodules that could benefit from computer-aided detection and diagnosis (CAD) in chest radiography. These include interstitial infiltrates, catheter tip detection, size measurements, detection of pneumothorax and detection and quantification of emphysema. Recent work in these areas is surveyed, but we conclude that the amount of research devoted to these topics is modest. Reasons for the slow pace of CAD development in chest radiography beyond nodules are discussed.

  17. Sedation versus general anaesthesia in paediatric patients undergoing chest CT

    Energy Technology Data Exchange (ETDEWEB)

    Lam, W.W.M.; So, N.M.C.; Metreweli, C. [Chinese Univ. of Hong Kong, Dept. of Diagnostic Radiology and Organ Imaging (China); Chen, P.P. [Chinese Univ. of Hong Kong, Anaesthesiology and Intensive Care (China)

    1998-05-01

    Objective: CT of the chest in paediatric patients often requires sedation or general anaesthesia to minimize motion artefacts. Both sedation and general anaesthesia are associated with atelectasis which obscures the underlying pulmonary pathology. We conducted a prospective study to compare these two methods with respect to degree of motion artefacts and extent of atelectasis. Material and Methods: Nineteen patients undergoing 22 chest CT examinations were randomly selected for either sedation or general anaesthesia. The total area of atelectasis and the degree of motion artefacts were measured. Results: The mean percentage of atelectasis was 6.67% for general anaesthesia and 0.01% for sedation (p=0.01). There was no significant difference in the quality of the images between the sedation patients and the general anaesthesia patients. Conclusion: Whenever the clinical condition permits it, sedation rather than general anaesthesia should be given to paediatric patients undergoing chest CT. (orig.).

  18. Palpation for muscular tenderness in the anterior chest wall

    DEFF Research Database (Denmark)

    Christensen, Henrik Wulff; Vach, Werner; Manniche, Claus;

    2003-01-01

    OBJECTIVE: To asses the interobserver and intraobserver reliability (in terms of day-to-day and hour-to-hour reliability) of palpation for muscular tenderness in the anterior chest wall. DESIGN: A repeated measures designs was used. SETTING: Department of Nuclear Medicine, Odense University...... Hospital, Denmark. PARTICIPANTS: Two experienced chiropractors examined 29 patients and 27 subjects in the interobserver part, and 1 of the 2 chiropractors examined 14 patients and 15 subjects in the intraobserver studies. INTERVENTION: Palpation for muscular tenderness was done in 14 predetermined areas...... palpating for intercostal tenderness or tenderness in the minor and major pectoral muscles in a population of patients with and without chest pain. This may hamper the ability of clinicians to diagnose and classify the musculoskeletal component of chest pain if based exclusively on palpation of the anterior...

  19. Ventilation distribution and chest wall mechanics in microgravity

    Science.gov (United States)

    Paiva, M.; Wantier, M.; Verbanck, S.; Engel, L. A.; Prisk, G. K.; Guy, H. J. B.; West, J. B.

    1997-01-01

    The effect of gravity on lung ventilation distribution and the mechanisms of the chest wall were investigated. The following tests were performed with the respiratory monitoring system of the Anthorack, flown onboard Spacelab D2 mission: single breath washout (SBW), multiple breath washout (MBW) and argon rebreathing (ARB). In order to study chest wall mechanisms in microgravity, a respiratory inductive plethysmograph was used. The SBW tests did not reach statistical significance, while the ARB tests showed that gravity independent inhomogeneity of specific ventilation is larger than gravity dependent inhomogeneity. In which concerns the chest wall mechanisms, the analysis on the four astronauts during the normal respirations of the relaxation maneuver showed a 40 percent increase on the abdominal contribution to respiration.

  20. Mesenchymal hamartoma of the chest wall in an infant.

    Science.gov (United States)

    Ayadi-Kaddour, A; Mlika, M; Chaabouni, S; Kilani, T; El Mezni, F

    2007-12-01

    Mesenchymal hamartoma of the chest wall is a very rare, benign tumour with distinct clinical, radiological and histopathologic characteristics. The lesion develops during foetal life, and is present at or shortly after birth with an extrapleural mass arising from the rib cage with or without respiratory distress and marked rib deformity. Several imaging techniques have been used for diagnosis, but a definitive diagnosis is established only by histopathological examination. Such lesions are composed of a varying admixture of hyaline cartilage that has features resembling growth plate cartilage, along with fascicles of spindle cells, woven bone and hemorrhagic cysts. Accurate diagnosis of mesenchymal hamartoma is important since many chest wall masses in children are malignant. We report a case of mesenchymal hamartoma of the left posterior chest wall surgically resected in an infant who was found to have a palpable mass at birth. Two years after surgery, the patient is alive and well, with no evidence of recurrence.

  1. HRCT findings of chest complications in patients with leukemia

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Nobuyuki; Matsumoto, Tsuneo; Miura, Gouji; Emoto, Takuya; Matsunaga, Naofumi [Department of Radiology, Yamaguchi University School of Medicine (Japan)

    2002-06-01

    High-resolution CT (HRCT) findings of several chest complications occurring in leukemic patients were reviewed. Although most entities show non-specific HRCT findings including ground-glass opacity and air-space consolidation, characteristic findings are observed in several pulmonary complications including Pneumocystis carinii pneumonia, fungal infections, miliary tuberculosis, leukemic infiltration, pulmonary edema, bronchiolitis obliterans, and bronchiolitis obliterans organizing pneumonia. A combination of these characteristic HRCT findings and the information obtained from the clinical setting may help in achieving a correct diagnosis of chest complications occurring in leukemic patients. (orig.)

  2. Computer Analysis Of ILO Standard Chest Radiographs Of Pneumoconiosis

    Science.gov (United States)

    Li, C. C.; Shu, David B. C.; Tai, H. T.; Hou, W.; Kunkle, G. A.; Wang, Y.; Hoy, R. J.

    1982-11-01

    This paper presents study of computer analysis of the 1980 ILO standard chest radiographs of pneumoconiosis. Algorithms developed for detection of individual small rounded and irregular opacities have been experimented and evaluated on these standard radiographs. The density, shape, and size distribution of the detected objects in the lung field, in spite of false positives, can be used as indicators for the beginning of pneumoconiosis. This approach is potentially useful in computer-assisted screening and early detection process where the annual chest radiograph of each worker is compared with his (her) own normal radiograph obtained previously.

  3. Chest wall involvement as a manifestation of Brucellosis

    Directory of Open Access Journals (Sweden)

    K Rahmdel

    2011-01-01

    Full Text Available Brucellosis continues to be a common infectious disease in some parts of the world. Although the disease has different presentations, but chest wall involvement, as a manifestation of brucellosis is rare. In this study, we report three cases of chest wall involvement as manifesting feature of Brucellosis in Iran. They presented with a history of parasternal masses revealed to a diagnosis of Brucellosis and responded well to the treatment. Brucellosis may present with strange and unpredictable manifestations and can be misdiagnosed with tuberculosis and malignancies, especially in endemic areas for both TB and brucellosis.

  4. Chest injuries in civilian practice (A study of 166 cases

    Directory of Open Access Journals (Sweden)

    Mandke N

    1979-01-01

    Full Text Available Chest injuries constitute a large number of patients admitted in our Intensive Trauma Care Unit. The maximum incidence is in the age group of 20-40 years. Contusions, fracture ribs, pneumo-haemothorax constitute major thoracic injuries. Visceral injuries were always kept in mind while treating these patients with critical condition. Most of the patients could be treated with only active conservativemanagement with proper use of respirators in selected patients. Surgical intervention was required in the patients mostly with visceral injuries. The mortality rate in pure chest injuries is very low. The as-sociated head injuries and abdominal injuries increased the overall mortality rate.

  5. Anthropometric characteristics of chest in youths of different somatic types

    Directory of Open Access Journals (Sweden)

    Zlobin O.O.

    2011-03-01

    Full Text Available Objective: to identify patterns of individual and combined anatomic variability of the size characteristics of the chest in conjunction with somatic types of youths 17-19 years. The object of study: boys, students (n=162, Saratov State Medical University n.a. V.I. Razumovsky, are natives of the Saratov region. The results showed that most youths are mesomorphic normotrofnomu, brachymorphic normotrofnomu and mesomorphic somatotype gipotrofnomu. Studied anthropometric parameters of the chest are statistically significant differences in all the selected somatotype

  6. Melioidosis:a rare cause of anterior chest wall abscess

    Institute of Scientific and Technical Information of China (English)

    Rashidi Ahmad; Azhar Amir Hamzah; Ahmad Kasfi Abdul Rahman; Phee Kheng Cheah

    2010-01-01

    Melioidosis is an unusual tropical infectious disease caused by the gram-negative bacterium Burkholderia pseudomallei, which was formerly known asPseudomonas pseudomallei. Melioidosis is characterized by abscess formation and it may manifest in any part of the human body, however, musculoskeletel melioidosis is uncommon and chest wall melioidosis is very rare. To determine the exact organism based solely on clinical presentation poses a great challenge to the physician. Yet, delay administration of antibiotic may be harmful. We describe a diabetic patient who had anterior chest wall melioidosis that mimicsStaphylococcus aureus infection. A description of his presentation and management, along with a review of literature is presented.

  7. Comparison of high frequency chest compression and conventional chest physiotherapy in hospitalized patients with cystic fibrosis.

    Science.gov (United States)

    Arens, R; Gozal, D; Omlin, K J; Vega, J; Boyd, K P; Keens, T G; Woo, M S

    1994-10-01

    Clearance of bronchial secretions is essential in the management of cystic fibrosis (CF) patients admitted for acute pulmonary exacerbation. Conventional physiotherapy (CPT) is labor-intensive, time-consuming, expensive, and may not be available as frequently as desired during hospitalization. High frequency chest compression (HFCC), which uses an inflatable vest linked to an air-pulse delivery system, may offer an attractive alternative. To study this, we prospectively studied 50 CF patients admitted for acute pulmonary exacerbation who were randomly allocated to receive either HFCC or CPT three times a day. On admission, clinical status and pulmonary function tests (PFT) in the HFCC group were not significantly different from those measured in the CPT group. Significant improvements in clinical status and PFT were observed after 7 and 14 d of treatment, and were similar in the two study groups, leading to patient discharge after similar periods of hospitalization. We conclude that HFCC and CPT are equally safe and effective when used during acute pulmonary exacerbations in CF patients. We speculate that HFCC may provide an adequate alternative in management of CF patients in a hospital setting.

  8. An Unusual Presentation of Adult Tethered Cord Syndrome Associated with Severe Chest and Upper Back Pain

    Directory of Open Access Journals (Sweden)

    Shotaro Kanda

    2015-01-01

    Full Text Available Adult tethered cord syndrome (ATCS is a rare entity that usually presents with multiple neurological symptoms, including lower extremity pain, backache, lower extremity muscle weakness, and bowel/bladder disturbances. Prompt surgical treatment is often necessary to avoid permanent sequelae. We report a 63-year-old man with sudden-onset severe right chest and upper back pain, followed by urinary retention. His initial workup included computed tomography of the abdomen and pelvis, which showed a presacral mass. His symptom-driven neurological workup focused on the cervical and thoracic spine, the results of which were normal. Pelvic radiographs and magnetic resonance imaging of the lumbosacral spine showed spina bifida occulta, meningocele, and presacral masses consistent with a teratomatous tumor. His symptoms, except for urinary retention, improved dramatically with surgical treatment. The excised specimen contained a teratomatous lesion plus an organized hematoma. Hematoma formation was suspected as the trigger of his sudden-onset right chest and upper back pain.

  9. Integration of ultra-high field MRI and histology for connectome based research of brain disorders

    Directory of Open Access Journals (Sweden)

    Shan eYang

    2013-09-01

    Full Text Available Ultra-high field magnetic resonance imaging (MRI became increasingly relevant for in vivo neuroscientific research because of improved spatial resolutions. However, this is still the unchallenged domain of histological studies, which long played an important role in the investigation of neuropsychiatric disorders. While the field of biological psychiatry strongly advanced on macroscopic levels, current developments are rediscovering the richness of immunohistological information when attempting a multi-level systematic approach to brain function and dysfunction. For most studies, histology sections lost information on three-dimensional reconstructions. Translating histological sections to 3D-volumes would thus not only allow for multi-stain and multi-subject alignment in post mortem data, but also provide a crucial step in big data initiatives involving the network analyses currently performed with in vivo MRI. We therefore investigated potential pitfalls during integration of MR and histological information where no additional blockface information is available. We demonstrated that strengths and requirements from both methods seem to be ideally merged at a spatial resolution of 200 μm. However, the success of this approach is heavily dependent on choices of hardware, sequence and reconstruction. We provide a fully automated pipeline that optimizes histological 3D reconstructions, providing a potentially powerful solution not only for primary human post mortem research institutions in neuropsychiatric research, but also to help alleviate the massive workloads in neuroanatomical atlas initiatives. We further demonstrate (for the first time the feasibility and quality of ultra-high spatial resolution (150 µm isotopic imaging of the entire human brain MRI at 7T, offering new opportunities for analyses on MR-derived information.

  10. Heat flux mitigation by impurity seeding in high-field tokamaks

    Science.gov (United States)

    Reinke, M. L.

    2017-03-01

    The ability for tokamaks to exhaust power in the boundary via impurity radiation is explored using empirical scalings and a simple 0D exhaust model, focusing on the scaling with toroidal field and major radius. By combining a scaling for the heat flux width and the L-H threshold power, the parallel heat flux in the SOL is shown to scale strongly with magnetic field, {{q}\\parallel}∼ B\\text{T}2.52 while having little to no scaling with machine size, {{q}\\parallel}∼ {{R}0.16} . Despite the increased heat flux at high field, it is shown that target temperatures relevant to detachment can be reached with finite main-ion dilution for a variety of impurity seeding gases, although non-equilibrium ionization balance is required in most cases. The necessary impurity fractions are estimated to scale like {{f}Z}∼ B\\text{T}0.88{{R}1.33} , a result that is facilitated by an increase in upstream temperature at high {{q}\\parallel} relative to peaks in the impurity cooling-curves. This scaling indicates that for optimizing reactors, minimizing device size while maximizing toroidal field, an approach shown to be consistent with energy confinement scaling, will also maximize the feasibility of reaching detachment at the lowest dilution. Despite this, analysis suggests an increase in the impurity fractions relative to existing devices will be required to exhaust power in a reactor-scale tokamak, with validation of impurity radiation physics required before both simple and detailed models can make reliable predictions of absolute f Z .

  11. High Field Sodium MRI Assessment of Stem Cell Chondrogenesis in a Tissue-Engineered Matrix.

    Science.gov (United States)

    Majumdar, Shreyan; Pothirajan, Padmabharathi; Dorcemus, Deborah; Nukavarapu, Syam; Kotecha, Mrignayani

    2016-04-01

    The development of non-invasive assessment techniques in vitro and in vivo is essential for monitoring and evaluating the growth of engineered cartilage tissues. Magnetic resonance imaging (MRI) is the leading non-invasive imaging modality used for assessing engineered cartilage. Typical MRI uses water proton relaxation times (T1 and T2) and apparent diffusion coefficient (ADC) to assess tissue growth. These techniques, while excellent in providing the first assurance of tissue growth, are unspecific to monitor the progress of engineered cartilage extracellular matrix components. In the current article, we present high field (11.7 T, (1)H freq. = 500 MHz) sodium MRI assessment of tissue-engineered cartilage at the early stage of tissue growth in vitro. We observed the chondrogenesis of human bone marrow derived stromal cells seeded in a gradient polymer-hydrogel matrix made out of poly(85 lactide-co-15 glycolide)--PuraMatrix™ for 4 weeks. We calculated the sodium concentration in the engineered constructs using a model of sodium MRI voxels that takes into account scaffold volume, cell density and amount of glycosaminoglycan (GAG). The sodium concentration was then converted to the fixed charge density (FCD) and compared with FCD derived from biochemical GAG analysis. Despite the small amount of GAG present in the engineered constructs, the sodium MRI derived FCD is found to be correlated (Pearson correlation coefficient R = 0.79) with the FCD derived from biochemical analysis. We conclude that sodium MRI could prove to be an invaluable tool in assessing engineered cartilage quantitatively during the repair or regeneration of cartilage defects.

  12. Localized Fisher vector representation for pathology detection in chest radiographs

    Science.gov (United States)

    Geva, Ofer; Lieberman, Sivan; Konen, Eli; Greenspan, Hayit

    2016-03-01

    In this work, we present a novel framework for automatic detection of abnormalities in chest radiographs. The representation model is based on the Fisher Vector encoding method. In the representation process, we encode each chest radiograph using a set of extracted local descriptors. These include localized texture features that address typical local texture abnormalities as well as spatial features. Using a Gaussian Mixture Model, a rich image descriptor is generated for each chest radiograph. An improved representation is obtained by selection of features that correspond to the relevant region of interest for each pathology. Categorization of the X-ray images is conducted using supervised learning and the SVM classifier. The proposed system was tested on a dataset of 636 chest radiographs taken from a real clinical environment. We measured the performance in terms of area (AUC) under the receiver operating characteristic (ROC) curve. Results show an AUC value of 0.878 for abnormal mediastinum detection, and AUC values of 0.827 and 0.817 for detection of right and left lung opacities, respectively. These results improve upon the state-of-the-art as compared with two alternative representation models.

  13. Lung contusion from focal low-moderate chest trauma.

    Science.gov (United States)

    Hafen, G M; Massie, J

    2006-10-01

    Apparently minor chest trauma may result in localized pulmonary contusion. Complications of the contusion, particularly infection, may be delayed. The association between the infection and initial injury may not be appreciated due to the time frame between the injury and clinical presentation. We report two cases of low-moderate impact pulmonary trauma resulting in focal pulmonary contusion, complicated by infection.

  14. Galactorrhea and hyperprolactinemia associated with chest wall injury.

    Science.gov (United States)

    Morley, J E; Dawson, M; Hodgkinson, H; Kalk, W J

    1977-11-01

    A 48 year old premenopausal woman presented with galactorrhea and amenorrhea associated with chest wall burns. Basal serum prolactin levels were raised, and were further elevated by the administration of L-dopa, chlorpromazine and TRH. Intercostal nerve block and bromocryptine treatment reduced prolactin levels to normal, but did not noticably reduce milk secretion.

  15. Diagnosis of chest pain with foregut symptoms in Chinese patients

    Institute of Scientific and Technical Information of China (English)

    Bo Deng; Ru-Wen Wang; Yao-Guang Jiang; Qun-You Tan; Xiang-Li Liao; Jing-Hai Zhou; Yun-Ping Zhao; Tai-Qian Gong; Zheng Ma

    2009-01-01

    AIM: To evaluate the diagnosis of chest pain with foregut symptoms in Chinese patients. METHODS: Esophageal manomet r ic studies, 24-h introesophageal pH monitoring and 24-h electrocardiograms (Holter electrocardiography) were performed in 61 patients with chest pain. RESULTS: Thirty-nine patients were diagnosed with non-specific esophageal motility disorders (29 patients with abnormal gastroesophageal reflux and eight patients with myocardial ischemia). Five patients had diffuse spasm of the esophagus plus abnormal gastroesophageal reflux (two patients had concomitant myocardial ischemia), and one patient was diagnosed with nutcracker esophagus. CONCLUSION: The esophageal manometric studies, 24-h intra-esophageal pH monitoring and Holter electrocardiography are significant for the differential diagnosis of chest pain, particularly in patients with foregut symptoms. In cases of esophageal motility disorders, pathological gastroesophageal reflux may be a major cause of chest pain with non-specific esophageal motility disorders. Spasm of the esophageal smooth muscle might affect the heart-coronary smooth muscle, leading to myocardial ischemia.

  16. Factors Associated with ICU Admission following Blunt Chest Trauma

    Science.gov (United States)

    Etteri, Massimiliano; Cantaluppi, Francesca; Pina, Paolo; Guanziroli, Massimo; Bianchi, AnnaMaria; Casazza, Giovanni

    2016-01-01

    Background. Blunt chest wall trauma accounts for over 10% of all trauma patients presenting to emergency departments worldwide. When the injury is not as severe, deciding which blunt chest wall trauma patients require a higher level of clinical input can be difficult. We hypothesized that patient factors, injury patterns, analgesia, postural condition, and positive airway pressure influence outcomes. Methods. The study population consisted of patients hospitalized with at least 3 rib fractures (RF) and at least one pulmonary contusion and/or at least one pneumothorax lower than 2 cm. Results. A total of 140 patients were retrospectively analyzed. Ten patients (7.1%) were admitted to intensive care unit (ICU) within the first 72 hours, because of deterioration of the clinical conditions and gas exchange with worsening of chest X-ray/thoracic ultrasound/chest computed tomography. On univariable analysis and multivariable analysis, obliged orthopnea (p = 0.0018) and the severity of trauma score (p pulmonary infections due to reduced tidal volume, namely, upright postural condition and positive airway pressure. PMID:28044070

  17. Effect of rib-cage structure on acoustic chest impedance

    DEFF Research Database (Denmark)

    Zimmermann, Niels Henrik; Møller, Henrik; Hansen, John;

    2011-01-01

    When a stethoscope is placed on the surface of the chest, the coupler picks up sound from heart and lungs transmitted through the tissues of the ribcage and from the surface of the skin. If the acoustic impedance of the chest surface is known, it is possible to optimize the coupler for picking up...... even weak sounds originating from e.g. the heart. The acoustic impedance is influenced by the structure of the ribcage; hence the acoustic impedance will change depending on if the coupler has been placed on a top of a rib or between the ribs (the intercostal). The impedance of the chest is measured...... in the frequency range from 40 Hz to 5 kHz using an acoustic impedance tube made specifically for the purpose. The measurements are carried out in a grid pattern on the surface of the chest. The grid is aligned according to the ribs; hence the measurements are either on a top of the ribs or between the ribs...

  18. Radical resection of giant chondrosarcoma of the anterior chest wall

    Directory of Open Access Journals (Sweden)

    Stanić Vojkan

    2008-01-01

    Full Text Available Background. Chondrosarcomas represent approximately 30% of primary malignant bone tumors, the most frequent of which is on anterior thoracic wall. Case report. We presented a case of 50-year-old man suffering from a slowgrowing, painless giant chondrosarcoma of the anterior chest wall. A wide resection was performed to excise the tumor including attached skin, right breast, ribs, sternum, soft tissues and parietal pleura. Mediastinum was not affected by the tumor. After resecting a 26 × 20 × 22 cm segment, the chest wall defect was reconstructed with a Marlex mesh and extensive latissimus dorsi myocutaneous flap pedicled on the right thoracodorsal vessels. Histopatology diagnosis was chondrosarcoma G 2−3. The mechanics of ventilation was not altered and respiratory function was normal from the immediate postoperative period. Three years after the operation postoperative results showed no local recurrence and excellent functional and aesthetic results were evident. Respiratory function remained unaltered. Conclusion. According to the results it can be concluded that the use of Marlex mash and myocutaneous flap is good method for stabilization of the chest wall and enough to avoid paradoxical respiratory movements in managing giant chondrosarcoma of the anterior chest wall.

  19. Prehospital chest tube thoracostomy: effective treatment or additional trauma?

    NARCIS (Netherlands)

    Spanjersberg, W.; Bergs, B.; Krijen, P.; Schipper, I.; Ringburg, A.; Steyerberg, E.W.; Edwards, M.J.R.; Schipper, I.B.; Vugt, A.B. van

    2005-01-01

    BACKGROUND: The use of prehospital chest tube thoracostomy (TT) remains controversial because of presumed increased complication risks. This study analyzed infectious complication rates for physician-performed prehospital and emergency department (ED) TT. METHODS: Over a 40-month period, all consecu

  20. A neonate with respiratory distress and a chest wall deformity.

    Science.gov (United States)

    Kerrey, Benjamin; Reed, Jennifer

    2007-08-01

    Infants with respiratory distress commonly present to a pediatric emergency department. There are rare but serious conditions that need to be considered in the differential diagnosis. We report the history of an infant that presented to our institution with respiratory distress ultimately diagnosed with a mesenchymal hamartoma of the chest wall. The presentation, diagnosis, and treatment options for mesenchymal hamartoma are discussed.

  1. Imaging of blunt chest trauma; Bildgebung des stumpfen Thoraxtraumas

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, H. [Medizinische Universitaet Wien, Allgemeines Krankenhaus, Univ.-Klinik fuer Radiologie und Nuklearmedizin, Wien (Austria); Negrin, L. [Medizinische Universitaet Wien, Allgemeines Krankenhaus, Univ.-Klinik fuer Unfallchirurgie, Wien (Austria)

    2014-09-15

    Blunt chest trauma is associated with high morbidity and mortality. Consequently, all patients should be evaluated radiologically after blunt chest trauma to allow timely and appropriate treatment. Conventional chest radiographs and computed tomography (CT) are proven modalities with which to evaluate patients after blunt chest trauma. Over the last several years extended focused assessment with sonography for trauma (eFAST) has gained increasing importance for the initial assessment of seriously injured patients. In the acute phase of severely injured patients eFAST examinations are helpful to exclude pneumothorax, hemothorax and hemopericardium. Chest radiographs may also be used to diagnose a pneumothorax or hemothorax; however, the sensitivity is limited and CT is the diagnostic modality of choice to evaluate severely injured patients. (orig.) [German] Stumpfe Thoraxtraumen gehen mit einer hohen Morbiditaet und Mortalitaet einher. Daher sollten Patienten mit Verdacht auf ein stumpfes Thoraxtrauma rasch radiologisch untersucht werden, damit die entsprechenden therapeutischen Schritte zeitgerecht eingeleitet werden koennen. Zur Abklaerung von Patienten nach einem stumpfen Thoraxtrauma sind seit Jahren das konventionelle Lungenroentgen und die Computertomographie bewaehrte Verfahren. In den letzten Jahren hat die fokussierte Ultraschalluntersuchung (eFAST, Extended Focused Assessment with Sonography for Trauma) von schwerverletzten Patienten vermehrt an Bedeutung gewonnen. Durch eine eFAST-Untersuchung kann in der Akutphase rasch geklaert werden, ob bei dem Patienten ein therapiebeduerftiger Pneumothorax, Haematoperikard oder Haematothorax vorliegen. Auch das Lungenroentgen wird zur Diagnose eines Pneumothorax oder Haematothorax eingesetzt, wenngleich seine Sensitivitaet deutlich eingeschraenkt ist. Die CT ist das diagnostische Verfahren der Wahl, um v. a. Patienten mit einem schweren Thoraxtrauma abzuklaeren. (orig.)

  2. An Official American Thoracic Society/American College of Chest Physicians Clinical Practice Guideline

    DEFF Research Database (Denmark)

    Girard, Timothy D; Alhazzani, Waleed; Kress, John P

    2017-01-01

    BACKGROUND: Interventions that lead to earlier liberation from mechanical ventilation can improve patient outcomes. This guideline, a collaborative effort between the American Thoracic Society (ATS) and the American College of Chest Physicians (CHEST), provides evidence-based recommendations to o...

  3. Permanent magnet design methodology

    Science.gov (United States)

    Leupold, Herbert A.

    1991-01-01

    Design techniques developed for the exploitation of high energy magnetically rigid materials such as Sm-Co and Nd-Fe-B have resulted in a revolution in kind rather than in degree in the design of a variety of electron guidance structures for ballistic and aerospace applications. Salient examples are listed. Several prototype models were developed. These structures are discussed in some detail: permanent magnet solenoids, transverse field sources, periodic structures, and very high field structures.

  4. A Computer-Aided Detection System for Digital Chest Radiographs

    Directory of Open Access Journals (Sweden)

    Juan Manuel Carrillo-de-Gea

    2016-01-01

    Full Text Available Computer-aided detection systems aim at the automatic detection of diseases using different medical imaging modalities. In this paper, a novel approach to detecting normality/pathology in digital chest radiographs is proposed. The problem tackled is complicated since it is not focused on particular diseases but anything that differs from what is considered as normality. First, the areas of interest of the chest are found using template matching on the images. Then, a texture descriptor called local binary patterns (LBP is computed for those areas. After that, LBP histograms are applied in a classifier algorithm, which produces the final normality/pathology decision. Our experimental results show the feasibility of the proposal, with success rates above 87% in the best cases. Moreover, our technique is able to locate the possible areas of pathology in nonnormal radiographs. Strengths and limitations of the proposed approach are described in the Conclusions.

  5. Pectus excavatum in blunt chest trauma: a case report

    Directory of Open Access Journals (Sweden)

    Liodakis Emmanouil

    2013-01-01

    Full Text Available Abstract Introduction Blunt cardiac rupture is an exceedingly rare injury. Case presentation We report a case of blunt cardiac trauma in a 43-year-old Caucasian German mother with pectus excavatum who presented after a car accident in which she had been sitting in the front seat holding her two-year-old boy in her arms. The mother was awake and alert during the initial two hours after the accident but then proceeded to hemodynamically collapse. The child did not sustain any severe injuries. Intraoperatively, a combined one-cm laceration of the left atrium and right ventricle was found. Conclusion Patients with pectus excavatum have an increased risk for cardiac rupture after blunt chest trauma because of compression between the sternum and spine. Therefore, patients with pectus excavatum and blunt chest trauma should be admitted to a Level I Trauma Center with a high degree of suspicion.

  6. Rheumatoid arthritis: Skeletal manifestations observed on portable chest roentgenograms

    Energy Technology Data Exchange (ETDEWEB)

    Levine, R.B.; Sullivan, K.L.

    1985-04-01

    This report describes the thoracic skeletal radiographic findings of rheumatoid arthritis, observed on portable chest examinations of 21 patients. The pathophysiology is reviewed and additional examples of a recently described finding are illustrated: erosion of the medial surface of the proximal humerus with subsequent pathologic fracture, associated with superior and medial migration of the humeral head. It has been proposed that erosion of the medial aspect of the proximal humerus is due to impingement wear, and that pathologic fracture results from the fulcrum effect of the inferior lip of the glenoid on the humerus. Rheumatoid arthritis is often diagnosed by the clinician rather than the radiologist. However, in acutely ill patients receiving portable chest radiographs, complete history and laboratory findings are often unavailable. Attention to the thoracic skeleton may clarify pleural and/or parenchymal lung disease in these patients.

  7. Chest roentgenology in the intensive care unit: an overview

    Energy Technology Data Exchange (ETDEWEB)

    Maffessanti, M. [Istituto di Radiologia, Universita di Trieste, Ospedale di Cattinara, I-34 100 Trieste (Italy); Berlot, G. [Istituto di Anestesia e Rianimazione, Universita di Trieste, Ospedale di Cattinara, I-34 100 Trieste (Italy); Bortolotto, P. [Servizio di Radiologia, Ospedale Maggiore, I-34 100 Trieste (Italy)

    1998-02-01

    Chest roentgenology in the intensive care unit is a real challenge for the general radiologist. Beyond the basic disease, the critically ill is at risk for developing specific cardiopulmonary disorders, all presenting as chest opacities, their diagnosis often being impossible if based only on the radiological aspect. To make things harder, their appearance can vary with the subject`s position and the mechanical ventilation. Patients require a continuous monitoring of the vital functions and their mechanical and pharmacological support, for which they are connected to different instruments. The radiologist should know the normal position of these devices, and promptly recognize when they are misplaced or when complications from their insertion occurred. Our aim is to suggest for each of the above-mentioned conditions a guideline of interpretation based not only on the radiological aspect and distribution of the lesions, but also on the physiopathological and clinical grounds. (orig.) With 13 figs., 58 refs.

  8. Detection of tuberculosis using hybrid features from chest radiographs

    Science.gov (United States)

    Fatima, Ayesha; Akram, M. Usman; Akhtar, Mahmood; Shafique, Irrum

    2017-02-01

    Tuberculosis is an infectious disease and becomes a major threat all over the world but still diagnosis of tuberculosis is a challenging task. In literature, chest radiographs are considered as most commonly used medical images in under developed countries for the diagnosis of TB. Different methods have been proposed but they are not helpful for radiologists due to cost and accuracy issues. Our paper presents a methodology in which different combinations of features are extracted based on intensities, shape and texture of chest radiograph and given to classifier for the detection of TB. The performance of our methodology is evaluated using publically available standard dataset Montgomery Country (MC) which contains 138 CXRs among which 80 CXRs are normal and 58 CXRs are abnormal including effusion and miliary patterns etc. The accuracy of 81.16% was achieved and the results show that proposed method have outperformed existing state of the art methods on MC dataset.

  9. Chest radiography in acute traumatic rupture of the thoracic aorta

    Energy Technology Data Exchange (ETDEWEB)

    Heystraten, F.M.; Rosenbusch, G.; Kingma, L.M.; Lacquet, L.K.; Boo, T. de; Lemmens, W.A.

    Of 123 patients who had suffered blunt trauma to the chest traumatic aortic rupture was eventually confirmed in 61 and absent in 62 patients. The chest radiographs of these patients were examined for 15 signs reported in the literature as being associated with traumatic aortic rupture. Although many individual signs were significantly more frequent in the aortic rupture group they were not useful in differentiating between patients with and those without rupture of the aorta. By using discriminant analysis combining 2 or 3 signs, patients were classified as having aortic rupture or not. The best discrimination between the two groups was obtained using the combined signs of a widened paratracheal stripe, and opacified pulmonary window, a widened right paraspinal interface and a displaced nasogastric tube.

  10. Thrombophlebitis of the lateral chest wall (Mondor′s disease

    Directory of Open Access Journals (Sweden)

    D Crisan

    2014-01-01

    Full Text Available Mondor′s disease is a rare condition, which involves the thrombophlebitis of the superficial veins of the breast and anterior chest wall. A 37-year-old woman presented with sudden onset of local pain and edema on her right chest wall, accompanied by a longitudinal retraction of the skin during arm abduction in the area. Clinical, histological and ultrasonographic findings confirmed Mondor′s disease and the treatment was symptomatic, using pain relievers and warm compresses. The symptomatology remitted within 2 weeks of therapy. Mondor′s disease is a rare condition where ultrasound complements the clinical evaluation and allows the characterization of certain abnormalities, which correlated with functional biochemical data and other procedures may substitute the need of biopsy.

  11. Musculoskeletal problems of the chest wall in athletes.

    Science.gov (United States)

    Gregory, Peter L; Biswas, Anita C; Batt, Mark E

    2002-01-01

    Chest pain in the athlete has a wide differential diagnosis. Pain may originate from structures within the thorax, such as the heart, lungs or oesophagus. However, musculoskeletal causes of chest pain must be considered. The aim of this review is to help the clinician to diagnose chest wall pain in athletes by identifying the possible causes, as reported in the literature. Musculoskeletal problems of the chest wall can occur in the ribs, sternum, articulations or myofascial structures. The cause is usually evident in the case of direct trauma. Additionally, athletes' bodies may be subjected to sudden large indirect forces or overuse, and stress fractures of the ribs caused by sporting activity have been extensively reported. These have been associated with golf, rowing and baseball pitching in particular. Stress fractures of the sternum reported in wrestlers cause pain and tenderness of the sternum, as expected. Diagnosis is by bone scan and limitation of activity usually allows healing to occur. The slipping rib syndrome causes intermittent costal margin pain related to posture or movement, and may be diagnosed by the 'hooking manoeuvre', which reproduces pain and sometimes a click. If reassurance and postural advice fail, good results are possible with resection of the mobile rib. The painful xiphoid syndrome is a rare condition that causes pain and tenderness of the xiphoid and is self-limiting. Costochondritis is a self-limiting condition of unknown aetiology that typically presents with pain around the second to fifth costochondral joints. It can be differentiated from Tietze's syndrome in which there is swelling and pain of the articulation. Both conditions eventually settle spontaneously although a corticosteroid injection may be useful in particularly troublesome cases. The intercostal muscles may be injured causing tenderness between the ribs. Other conditions that should be considered include epidemic myalgia, precordial catch syndrome and referred pain

  12. Clinical Implications High Frequency Chest Wall Oscillation (HFCWO)

    OpenAIRE

    Mantellini E.; Perrero L.; Petrozzino S.; Gatta A.; Bona S.

    2012-01-01

    Purpose: patients with neuromuscular diseases presents an high incidence of respiratory infections favoured by stagnation of deep bronchial secretions and deficit of cough. The aim of the study is to evaluate the correct treatment of this condition and the role of High Frequency Chest Wall Oscillation (HFCWO) in helping the removal of bronchial secretions and reduce the incidence of infections in patients with neuromuscular disease.Methods: analysis of the current bibliography related to resp...

  13. Computer Assisted Diagnosis of Chest Pain. Preliminary Manual

    Science.gov (United States)

    1984-04-27

    recent change In appetite) "NORMAL (57) DECREASED. BOWELS: [recent change in bowel habits ) NORMAL 159) CONSTIPATED fi60tf cough...irritation from food or drink, by reflux of gastric contents, or by infection (the latter is uncommon in healthy people). There is a good response to...have a physical etiology for chest pain. Disorders that present with epigastric pain such as gastritis , peptic ulcer, pancreatitis, and cholelithiasis

  14. Chest trauma nursing%胸部创伤护理

    Institute of Scientific and Technical Information of China (English)

    何海燕; 曾登芬; 张连阳; 郑志伟

    2014-01-01

    胸部创伤是导致创伤患者死亡的主要原因之一。胸部创伤护理的主要内容包括伤情评估、血流动力学等监测、胸腔引流和肺部治疗。面对胸部创伤患者,通过初期和再次评估,以及心肺功能和氧合状态的持续监测,及时发现和处理危及机生命的损伤及其并发症;通过管道护理、漏气观察,保持有效的胸腔引流;而胸部物理治疗、体位治疗、吸痰等措施有助于改善肺部通气和血流灌注,使患者达到最大程度的氧合。%Chest trauma is a leading cause of death in all age groups .The assessment of the injury and the change of hemodynamics ,management of the pleural space drainage systems ,and pulmonary treatment are essential components of chest trauma nursing .To survey and monitor the patients carefully and continuingly can help identify and intervene the life-threatening conditions .Chest tube care and air leak examination are the key points to keep the drainage effective.Furthermore,with chest physiotherapy,suctioning,and injury-specific positioning,the ventilation, perfusion and oxygenation of patients can be improved .

  15. Computer Assisted Diagnosis of Chest Pain. Adjunctive Treatment Protocols

    Science.gov (United States)

    1984-07-30

    If rales are not heard upon chest exam and peripheral edema is absent, the impairment is (at least temporarily) adequately compensated. USUAL...impressions. COMPLICATIONS AND THEIR MANAGEMENT - Uncontrolled dysrhythmias and cardiogenic shock are the complications of concern. Bursts of PVC’s (or...problem. The cardiac compromise due to M.I. may be manifested by minimal rales and dyspnea or massive pulmonary edema with shock. Lasix is

  16. Acute aortic and mitral valve regurgitation following blunt chest trauma.

    Science.gov (United States)

    Bernabeu, Eduardo; Mestres, Carlos A; Loma-Osorio, Pablo; Josa, Miguel

    2004-03-01

    Traumatic rupture of intracardiac structures is an uncommon phenomenon although there are a number of reports with regards to rupture of the tricuspid, mitral and aortic valves. We report the case of a 25-year-old patient who presented with acute aortic and mitral valve regurgitation of traumatic origin. Both lesions were seen separated by 2 weeks. Pathophysiology is reviewed. The combination of both aortic and mitral lesions following blunt chest trauma is almost exceptional.

  17. Aspects of chest imaging in the intensive care unit.

    Science.gov (United States)

    Cascade, P N; Kazerooni, E A

    1994-04-01

    Timely performance and accurate interpretation of portable chest radiographs in the ICU setting are fundamental components of quality care. Teamwork between intensive care clinicians and radiologists is necessary to assure that the appropriate studies, of high technical quality, are obtained. By working together to integrate available clinical information with systematic comprehensive analysis of images, accurate diagnoses can be made, optimal treatment instituted, and successful outcomes optimized.

  18. LECTURES ON ACUPUNCTURE Part Ⅰ Clinical Acupuncture Lecture Twenty-Four "XIONGBI" (CHEST PAIN) SYNDROME

    Institute of Scientific and Technical Information of China (English)

    Dong Hongying; Guo Ling; Shang Xiukui

    2001-01-01

    @@ "Xiongbi" chest (or precordial) pain with stuffiness, or chest pain syndrome is referred to choking pain in the chest due to stagnation of chest -yang, failure of qi and blood in warming and nourishing the local meridians. It is usually caused by stagnation of dampness and phlegm in the interior, or by insufficiency of qi and blood stasis, leading to impeded flow of qi and blood in the heart vessels. Its pathological characteristics are deficiency (chest-yang) in origin and excess (i. e., qi stagnation) in superficiality. The therapeutic principles are promoting blood circulation to remove blood stasis, getting rid of blockage and dredging the passages of yang-qi.

  19. Zebrafish Caudal Haematopoietic Embryonic Stromal Tissue (CHEST) Cells Support Haematopoiesis

    Science.gov (United States)

    Wolf, Anja; Aggio, Julian; Campbell, Clyde; Wright, Francis; Marquez, Gabriel; Traver, David; Stachura, David L.

    2017-01-01

    Haematopoiesis is an essential process in early vertebrate development that occurs in different distinct spatial locations in the embryo that shift over time. These different sites have distinct functions: in some anatomical locations specific hematopoietic stem and progenitor cells (HSPCs) are generated de novo. In others, HSPCs expand. HSPCs differentiate and renew in other locations, ensuring homeostatic maintenance. These niches primarily control haematopoiesis through a combination of cell-to-cell signalling and cytokine secretion that elicit unique biological effects in progenitors. To understand the molecular signals generated by these niches, we report the generation of caudal hematopoietic embryonic stromal tissue (CHEST) cells from 72-hours post fertilization (hpf) caudal hematopoietic tissue (CHT), the site of embryonic HSPC expansion in fish. CHEST cells are a primary cell line with perivascular endothelial properties that expand hematopoietic cells in vitro. Morphological and transcript analysis of these cultures indicates lymphoid, myeloid, and erythroid differentiation, indicating that CHEST cells are a useful tool for identifying molecular signals critical for HSPC proliferation and differentiation in the zebrafish. These findings permit comparison with other temporally and spatially distinct haematopoietic-supportive zebrafish niches, as well as with mammalian haematopoietic-supportive cells to further the understanding of the evolution of the vertebrate hematopoietic system. PMID:28300168

  20. [Psychosomatic medicine for non-cardiac chest pain].

    Science.gov (United States)

    Funakoshi, Seiko; Hosoi, Masako; Tsuchida, Osamu

    2009-09-01

    Recently, it has become problematic that the number of noncardiac chest pain (NCCP) patients are increasing among those who come to the emergency room with chest pain as a chief complaint. They tend to come to hospitals often and over many years, even after cardiac-chest pain has been excluded from their diagnosis. Moreover, studies have shown that NCCP patients have a high prevalence of anxiety, depression and disability. However, most NCCP patients are usually treated by cardiologists or primary physicians. Ordinary biomedical approaches often fail to treat NCCP. NCCP is one of the most important functional somatic syndromes from the view of medical economics. The cause of NCCP includes gastroesophageal reflux disease, panic disorder and esophageal dysmotility. In this review article, we summarize the definition, epidemiology, pathology, and process of diagnosis of NCCP. Finally, we propose a pathological hypothesis from a psychosomatic view. We discuss the effects of anxiety, fear and hyperactive behavior induced by affective stressors on the dysmotility and the lowering of the pain threshold.

  1. Risks of Chest X-ray Examination for Students

    Directory of Open Access Journals (Sweden)

    Nohara,Takahiko

    2009-02-01

    Full Text Available

    Chest X-ray (CXR examination is considered essential for health checkups of students;thus, it is important to objectively assess the CXR for a better understanding of the appropriate X-ray exposure dose, and the risks such an examination entails. Accordingly, we performed a multi-institutional study regarding students' CXR exposure, during a 6year-period from 2002 (partially including 2001 to 2007, with the collaboration of national, municipal, and private universities and colleges in Japan. A glass badge was worn by the students at the time of CXR screening examination. These glass badges were collected, and their X-ray exposure doses were measured. The results indicated a tendency of decreasing exposure dose over the 6 years, though the difference was not significant. In a comparison of the chest X-ray systems within institutions (own X-ray equipmentinside systems with those outside the institution (mobile X-ray equipmentoutside systems, the average exposure dose with the outside systems exceeded that of the inside systems. Both inside and outside systems included a few X-ray machines with which the exposure was more than 1mSv. Based on these facts, individuals in charge of student health checkups should be aware of the exposure dose of each chest fluorographic system at their institution.

  2. Chest Pain: The Need to Consider Less Frequent Diagnosis

    Science.gov (United States)

    Morais, Anabela; Carvalho, Sofia; Cunha, Joana; Lima, Ana R.; Moreira, J. Ilídio; Faria, Trigo

    2016-01-01

    Chest pain is one of the most frequent patient's complaints. The commonest underlying causes are well known, but, sometimes, in some clinical scenarios, it is necessary to consider other diagnoses. We report a case of a 68-year-old Caucasian male, chronically hypertensive, who complained of recurrent episodes of chest pain and fever with elevated acute phase reactants. The first investigation was negative for some of the most likely diagnosis and he quickly improved with anti-inflammatory drugs. Over a few months, his symptoms continued to recur periodically, his hypertension was aggravated, and he developed headaches and lower limbs claudication. After a temporal artery biopsy that was negative for vasculitis, he underwent a positron emission tomography suggestive of Takayasu Arteritis. Takayasu Arteritis is a rare chronic granulomatous vasculitis of the aorta and its first-order branches affecting mostly females up to 50 years old. Chest pain is experienced by >40% of the patients and results from the inflammation of the aorta, pulmonary artery, or coronaries. PMID:27034853

  3. Initial clinical evaluation of stationary digital chest tomosynthesis

    Science.gov (United States)

    Hartman, Allison E.; Shan, Jing; Wu, Gongting; Lee, Yueh Z.; Zhou, Otto; Lu, Jianping; Heath, Michael; Wang, Xiaohui; Foos, David

    2016-03-01

    Computed Tomography (CT) is the gold standard for image evaluation of lung disease, including lung cancer and cystic fibrosis. It provides detailed information of the lung anatomy and lesions, but at a relatively high cost and high dose of radiation. Chest radiography is a low dose imaging modality but it has low sensitivity. Digital chest tomosynthesis (DCT) is an imaging modality that produces 3D images by collecting x-ray projection images over a limited angle. DCT is less expensive than CT and requires about 1/10th the dose of radiation. Commercial DCT systems acquire the projection images by mechanically scanning an x-ray tube. The movement of the tube head limits acquisition speed. We recently demonstrated the feasibility of stationary digital chest tomosynthesis (s-DCT) using a carbon nanotube (CNT) x-ray source array in benchtop phantom studies. The stationary x-ray source allows for fast image acquisition. The objective of this study is to demonstrate the feasibility of s-DCT for patient imaging. We have successfully imaged 31 patients. Preliminary evaluation by board certified radiologists suggests good depiction of thoracic anatomy and pathology.

  4. High-Frequency Chest Compression: A Summary of the Literature

    Directory of Open Access Journals (Sweden)

    Cara F Dosman

    2005-01-01

    Full Text Available The purpose of the present literature summary is to describe high-frequency chest compression (HFCC, summarize its history and outline study results on its effect on mucolysis, mucus transport, pulmonary function and quality of life. HFCC is a mechanical method of self-administered chest physiotherapy, which induces rapid air movement in and out of the lungs. This mean oscillated volume is an effective method of mucolysis and mucus clearance. HFCC can increase independence. Some studies have shown that HFCC leads to more mucus clearance and better lung function compared with conventional chest physiotherapy. However, HFCC also decreases end-expiratory lung volume, which can lead to increased airway resistance and a decreased oscillated volume. Adding positive end-expiratory pressure to HFCC has been shown to prevent this decrease in end-expiratory lung volume and to increase the oscillated volume. It is possible that the HFCC-induced decrease in end-expiratory lung volume may result in more mucus clearance in airways that remain open by reducing airway size. Adjunctive methods, such as positive end-expiratory pressure, may not always be needed to make HFCC more effective.

  5. Chest Pain: The Need to Consider Less Frequent Diagnosis

    Directory of Open Access Journals (Sweden)

    Pedro Magalhães

    2016-01-01

    Full Text Available Chest pain is one of the most frequent patient’s complaints. The commonest underlying causes are well known, but, sometimes, in some clinical scenarios, it is necessary to consider other diagnoses. We report a case of a 68-year-old Caucasian male, chronically hypertensive, who complained of recurrent episodes of chest pain and fever with elevated acute phase reactants. The first investigation was negative for some of the most likely diagnosis and he quickly improved with anti-inflammatory drugs. Over a few months, his symptoms continued to recur periodically, his hypertension was aggravated, and he developed headaches and lower limbs claudication. After a temporal artery biopsy that was negative for vasculitis, he underwent a positron emission tomography suggestive of Takayasu Arteritis. Takayasu Arteritis is a rare chronic granulomatous vasculitis of the aorta and its first-order branches affecting mostly females up to 50 years old. Chest pain is experienced by >40% of the patients and results from the inflammation of the aorta, pulmonary artery, or coronaries.

  6. High-frequency chest compression: a summary of the literature.

    Science.gov (United States)

    Dosman, Cara F; Jones, Richard L

    2005-01-01

    The purpose of the present literature summary is to describe high-frequency chest compression (HFCC), summarize its history and outline study results on its effect on mucolysis, mucus transport, pulmonary function and quality of life. HFCC is a mechanical method of self-administered chest physiotherapy, which induces rapid air movement in and out of the lungs. This mean oscillated volume is an effective method of mucolysis and mucus clearance. HFCC can increase independence. Some studies have shown that HFCC leads to more mucus clearance and better lung function compared with conventional chest physiotherapy. However, HFCC also decreases end-expiratory lung volume, which can lead to increased airway resistance and a decreased oscillated volume. Adding positive end-expiratory pressure to HFCC has been shown to prevent this decrease in end-expiratory lung volume and to increase the oscillated volume. It is possible that the HFCC-induced decrease in end-expiratory lung volume may result in more mucus clearance in airways that remain open by reducing airway size. Adjunctive methods, such as positive end-expiratory pressure, may not always be needed to make HFCC more effective.

  7. Clinical Implications High Frequency Chest Wall Oscillation (HFCWO

    Directory of Open Access Journals (Sweden)

    Mantellini E.

    2012-01-01

    Full Text Available Purpose: patients with neuromuscular diseases presents an high incidence of respiratory infections favoured by stagnation of deep bronchial secretions and deficit of cough. The aim of the study is to evaluate the correct treatment of this condition and the role of High Frequency Chest Wall Oscillation (HFCWO in helping the removal of bronchial secretions and reduce the incidence of infections in patients with neuromuscular disease.Methods: analysis of the current bibliography related to respiratory infections and neuromuscular disease. PCEF (Peak Cough Expiratory Flow is used as a standardized indicator of efficiency of cough.Results: the High Frequency Chest Wall Oscillation (HFCWO is useful, in cases of increased production of mucus and impairment of muco-ciliary clearance, to remove the tracheobronchial secretions and reduce the incidence of infections.Conclusions: the correct approach to patients with neuromuscular disease and frequent respiratory infections is focused on treatment of cough ineffective and management of bronchial secretions. High Frequency Chest Wall Oscillation (HFCWO (VEST has a central role in treatment of cough ineffective and management of bronchial secretions reducing respiratory infections.

  8. Using "Rebar" to Stabilize Rigid Chest Wall Reconstruction.

    Science.gov (United States)

    Robinson, Lary A; Grubbs, Deanna M

    2016-04-01

    After major chest wall resection, reconstruction of the bony defect with a rigid prosthesis is mandatory to protect the underlying thoracic organs, and to prevent flail chest physiology. Although many methods have been described for chest wall reconstruction, a commonly used technique employs a composite Marlex (polypropylene) mesh with methyl-methacrylate cement sandwiched between two layers of mesh (MMS), which is tailored to the defect size and shape. In building construction, steel "rebar" is used to strengthen and reinforce masonry structures. To avoid the initial residual motion of the rigid prosthesis used to reconstruct very large defects, particularly the sternum, we devised a simple technique of adding one or more Steinmann steel pins as "rebar" to strengthen and immediately stabilize the prosthesis to the surrounding ribs and sternum. For the very large defects, particularly over the heart and great vessels, titanium mesh may also be readily added into the sandwich construction for increased strength and to prevent late prosthetic fractures. Short- and long-term results of this inexpensive modification of the MMS reconstruction technique are excellent. This modified MMS tailor-made prosthesis is only one-third the cost of the recently popular prosthetic titanium systems, takes much less operative time to create and implant, and avoids the well-described complications of late titanium bar fracture and erosion/infection as well as loosening of screws and/or titanium bars.

  9. Noninvasive monitoring of chest wall movement in infants using laser.

    Science.gov (United States)

    Kondo, Tsutomu; Minocchieri, Stefan; Baldwin, David N; Nelle, Mathias; Frey, Urs

    2006-10-01

    Traditionally, non-invasive monitoring of tidal volume in infants has been performed using impedance plethysmography analyzed using a one or two compartment model. We developed a new laser system for use in infants, which measures antero-posterior movement of the chest wall during quiet sleep. In 24 unsedated or sedated infants (11 healthy, 13 with respiratory disease), we examined whether the analysis of thoracoabdominal movement based on a three compartment model could more accurately estimate tidal volume in comparison to V(T) measured at the mouth. Using five laser signals, chest wall movements were measured at the right and left, upper and lower ribcage and the abdomen. Within the tidal volume range from 4.6 to 135.7 ml, a three compartment model showed good short term repeatability and the best agreement with tidal volume measured at mouth (r(2) = 0.86) compared to that of a single compartment model (r(2) = 0.62, P infants and potentially of regional differences of chest wall displacement in future studies.

  10. Differential points of mediastinal cystic lesion in chest computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Jin; Baek, Jang Mi; Song, Jang Hyeon; Seon, Hyun Ju [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Kim, Yun Hyeon [Dept. of Radiology, Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of)

    2013-10-15

    To find differential diagnostic imaging findings of mediastinal cystic lesions in chest computed tomography. We retrospectively reviewed imaging findings of 70 patients with histopathologically proven mediastinal cystic lesions. They were 33 male and 37 female patients. Among 70 cases, 49 cases were in the anterior mediastinum, 12 cases were in the middle mediastinum, and 9 cases were in the posterior mediastinum. 19 patients had symptoms. Chest discomfort was the most common symptom. When the cystic lesion was located in the anterior mediastinum, and unilocular, the possibility of thymic cyst was the most likely (p < 0.0027). When the cystic lesion was located in the anterior mediastinum and was multilocular with a relatively thick wall, the possibility of a mature cystic teratoma was the most likely (p < 0.001). When the lesion was a high attenuation cystic lesion located around the air-way, the possibility of a bronchogenic cyst was the most likely (p < 0.001). Chest CT gives information about the location, loculation, wall thickness and internal attenuation of mediastinal cystic lesions. And certain details seen on CT imaging can help with the correct diagnosis, especially in the cases of thymic cyst, mature cystic teratoma and bronchogenic cyst.

  11. High field side launch of RF waves: A new approach to reactor actuators

    Science.gov (United States)

    Wallace, G. M.; Baek, S. G.; Bonoli, P. T.; Faust, I. C.; LaBombard, B. L.; Lin, Y.; Mumgaard, R. T.; Parker, R. R.; Shiraiwa, S.; Vieira, R.; Whyte, D. G.; Wukitch, S. J.

    2015-12-01

    Launching radio frequency (RF) waves from the high field side (HFS) of a tokamak offers significant advantages over low field side (LFS) launch with respect to both wave physics and plasma material interactions (PMI). For lower hybrid (LH) waves, the higher magnetic field opens the window between wave accessibility (n∥≡c k∥/ω >√{1 -ωpi 2/ω2+ωpe 2/ωce 2 }+ωp e/|ωc e| ) and the condition for strong electron Landau damping (n∥˜√{30 /Te } with Te in keV), allowing LH waves from the HFS to penetrate into the core of a burning plasma, while waves launched from the LFS are restricted to the periphery of the plasma. The lower n∥ of waves absorbed at higher Te yields a higher current drive efficiency as well. In the ion cyclotron range of frequencies (ICRF), HFS launch allows for direct access to the mode conversion layer where mode converted waves absorb strongly on thermal electrons and ions, thus avoiding the generation of energetic minority ion tails. The absence of turbulent heat and particle fluxes on the HFS, particularly in double null configuration, makes it the ideal location to minimize PMI damage to the antenna structure. The quiescent SOL also eliminates the need to couple LH waves across a long distance to the separatrix, as the antenna can be located close to plasma without risking damage to the structure. Improved impurity screening on the HFS will help eliminate the long-standing issues of high Z impurity accumulation with ICRF. Looking toward a fusion reactor, the HFS is the only possible location for a plasma-facing RF antenna that will survive long-term. By integrating the antenna into the blanket module it is possible to improve the tritium breeding ratio compared with an antenna occupying an equatorial port plug. Blanket modules will require remote handling of numerous cooling pipes and electrical connections, and the addition of transmission lines will not substantially increase the level of complexity. The obvious engineering

  12. Elastic property of a high-field ordered state observed in PrFe{sub 4}P{sub 12}

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Y. [Graduate School of Engineering, Iwate University Morioka 020-8551 (Japan)], E-mail: yoshiki@iwate-u.ac.jp; Fujino, T.; Tanizawaa, T.; Nakamura, M. [Graduate School of Engineering, Iwate University Morioka 020-8551 (Japan); Sugawara, H. [Faculty of Integrated Arts and Sciences, The University of Tokushima, Tokushima 770-8502 (Japan); Kikuchi, D.; Sato, H. [Department of Physics, Tokyo Metropolitan University, Hachioji 192-0397 (Japan); Yoshizawa, M. [Graduate School of Engineering, Iwate University Morioka 020-8551 (Japan)

    2008-04-01

    We present experimental results of elastic constants as a function of temperature and magnetic field for understanding a newly discovered high-field (HF) phase, sharply located around the <111> direction of the magnetic field above 8 T, in the Pr-based heavy fermion system PrFe{sub 4}P{sub 12}. A clear upturn was observed in the elastic constants C{sub L}=(C{sub 11}+2C{sub 12}+4C{sub 44})/3 and C{sub T}=(C{sub 11}-C{sub 12}+C{sub 44})/3 below the HF ordered phase transition temperature, where C{sub L} and C{sub T} were measured by a longitudinal (L) sound wave propagating along the <111> direction and by a transverse (T) one along the <111> direction polarized to the <111> one, respectively. Furthermore, a remarkable elastic softening toward the transition temperature was observed in the temperature dependence of the C{sub L}, whereas no softening was observed in C{sub T}. These results indicate that the softening is most likely to be attributed to the bulk modulus (C{sub 11}+2C{sub 12})/3 or a change of crystal length along the <111> axis. Hence, a strain fluctuation with {gamma}{sub 1} symmetry or the crystal distortion along the <111> axis might be an important clue for the primary order parameter.

  13. Medic - Chest Pain: A Decision Support Program for the Management of Acute Chest Pain (User’s Manual)

    Science.gov (United States)

    1989-10-05

    push c) pulmonary edema (pinkish froth fron mouth and rales throughout lung fields) Lasix 40 mg IV push (consider rotating extremity tourniquets, if...varying degrees of impairment of myocardial function (pump failure). If rales are not heard upon chest exam and peripheral edema is absent, the...LIER M MEW Uncontrolled dysrhythmias and cardiogenic shock are the principal camplications of concern. PVC’s (more than 5 per minute) and V-tach (3 or

  14. Pediatric chest CT after trauma: impact on surgical and clinical management

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rina P. [Vanderbilt University School of Medicine, Nashville, TN (United States); Hernanz-Schulman, Marta; Hilmes, Melissa A.; Kan, J.H. [Vanderbilt University, Department of Radiology and Radiological Sciences, Vanderbilt Children' s Hospital, Nashville, TN (United States); Yu, Chang [Vanderbilt University, Department of Biostatistics, Nashville, TN (United States); Ray, Jackie [Vanderbilt University, Department of Pediatric Surgery, Vanderbilt Children' s Hospital, Nashville, TN (United States)

    2010-07-15

    Chest CT after pediatric trauma is frequently performed but its clinical impact, particularly with respect to surgical intervention, has not been adequately evaluated. To assess the impact of chest CT compared with chest radiography on pediatric trauma management. Two hundred thirty-five consecutive pediatric trauma patients who had both chest CT and radiography were identified. Images were reviewed and findings were categorized and correlated with subsequent chest interventions, blinded to final outcome and management. Of the 235 children, 38.3% (90/235) had an abnormal chest radiograph and 63.8% (150/235) had an abnormal chest CT (P < 0.0001). Chest interventions followed in 4.7% (11/235); of these, the findings could be made 1 cm above the dome of the liver in 91% (10/11). Findings requiring chest intervention included pneumothorax (PTX) and vertebral fractures. PTX was found on 2.1% (5/235) of chest radiographs and 20.0% (47/235) of chest CTs (P < 0.0001); 1.7% (4/235) of the children received a chest tube for PTX, 0.85% (2/235) seen on chest CT only. Vertebral fractures were present in 3.8% of the children (9/235) and 66.7% (6/9) of those cases were treated with spinal fusion or brace. There were no instances of mediastinal vascular injury. Most intrathoracic findings requiring surgical management in our population were identified in the lower chest and would be included in routine abdominopelvic CT exams; this information needs to be taken into consideration in the diagnostic algorithm of pediatric trauma patients. (orig.)

  15. The influence of chest tube size and position in primary spontaneous pneumothorax

    Science.gov (United States)

    Riber, Lars P. S.; Olesen, Winnie H.; Licht, Peter B.

    2017-01-01

    Background Optimal chest tube position in the pleural cavity is largely unexplored for the treatment of primary spontaneous pneumothorax (PSP). We investigated whether type, size and position of chest tubes influenced duration of treatment for PSP. Methods A retrospective follow-up study of all patients admitted with PSP over a 5-year period. Traumatic, iatrogenic and secondary pneumothoraxes were excluded. Gender, age, smoking habits, type and size of chest tube used (pigtail catheter or surgical chest tube) were recorded from the patients’ charts. All chest X-rays upon admittance and immediately following chest tube placement were retrieved and re-evaluated for size of pneumothorax (categorized into five groups) and location of the chest tube tip (categorized as upper, middle or lower third of the pleural cavity). All data were analysed in a Cox proportional hazards regression model. Results We identified 134 patients with PSP. Baseline characteristics were similar for patients treated with surgical chest tubes and pigtail catheters. Chest tube duration was not significantly influenced by position of the chest tube tip, but was significantly longer in females (P<0.01), patients <30 years (P=0.01), larger pneumothoraxes (P<0.01), use of surgical chest tubes (P=0.03) and a history of previous pneumothorax (P=0.04). Conclusions Contrary to common belief and guidelines recommendation the position of a chest tube in the pleural cavity did not significantly influence chest tube duration, but it was significantly longer in patients who were treated with a surgical chest tube. PMID:28275481

  16. Evaluation of chest pain in the emergency department.

    Science.gov (United States)

    Jesse, R L; Kontos, M C

    1997-04-01

    The evaluation of chest pain in the emergency setting should be systematic, risk based, and goal driven. An effective program must be able to evaluate all patients with equal thoroughness under the assumption that any patient with chest pain could potentially be having an MI. The initial evaluation is based on the history, a focused physical examination, and the ECG. This information is sufficient to categorize patients into groups at high, moderate, and low risk. Table 14 is a template for a comprehensive chest-pain evaluation program. Patients at high risk need rapid initiation of appropriate therapy: thrombolytics or primary angioplasty for the patients with MIs or aspirin/heparin for the patients with unstable angina. Patients at moderate risk need to have an acute coronary syndrome ruled in or out expediently and additional comorbidities addressed before discharge. Patients at low risk also need to be evaluated, and once the likelihood of an unstable acute coronary syndrome is eliminated, they can be discharged with further evaluation performed as outpatients. Subsequent evaluation should attempt to assign a definitive diagnosis while also addressing issues specific to risk reduction, such as cholesterol lowering and smoking cessation. It is well documented that 4% to 5% of patients with MIs are inadvertently missed during the initial evaluation. This number is surprisingly consistent among many studies using various protocols and suggests that an initial evaluation limited to the history, physical examination, and ECG will fail to identify the small number of these patients who otherwise appear at low risk. The solution is to improve the sensitivity of the evaluation process to identify these patients. It appears that more than simple observation is required, and at the present time, no simple laboratory test can meet this need. However, success has been reported with a number of strategies including emergency imaging with either radionuclides such as

  17. Alpha Channeling with High-field Launch of Lower Hybrid Waves

    CERN Document Server

    Ochs, Ian E; Fisch, Nathaniel J

    2015-01-01

    Although lower hybrid waves are effective at driving currents in present-day tokamaks, they are expected to interact strongly with high-energy particles in extrapolating to reactors. In the presence of a radial alpha particle birth gradient, this interaction can take the form of wave amplification rather than damping. While it is known that this amplification more easily occurs when launching from the tokamak high-field side, the extent of this amplification has not been made quantitative. Here, by tracing rays launched from the high- field-side of a tokamak, the required radial gradients to achieve amplification are calculated for a temperature and density regime consistent with a hot-ion-mode fusion reactor. These simulations, while valid only in the linear regime of wave amplification, nonetheless illustrate the possibilities for wave amplification using high-field launch of the lower hybrid wave.

  18. Mucopolysaccharidosis: abnormal findings on abdomen and chest excluding musculoskeletal system

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Jeung Hee; Yoon, Dae Young; Seo, Young Lan; Han, Dae Hee; Choi, Chul Soon; Bae, Sang Hoon; Yoon, Young Cheol; Park, Sang Joon [Samsung Medical Center, Seoul (Korea, Republic of); Kim Han, Bok Yung; Yoon, Hye Kyung; Cho, Jae Min [Hallym University College of Medicine, Seoul (Korea, Republic of)

    2003-06-01

    Mucopolysaccharidosis (MPS) is a lysosomal storage disease that causes tissue distortion and dysfunction due to the infiltration of mucopolysaccharide in connective tissue. The purpose of this study was to evaluate the characteristic findings of abdominal CT and plain chest radiography in patients with MPS. Sixty-two children with MPS diagnosed by urine analysis were involved in this study; 24 of these underwent abdominal CT and the findings were reviewed by two radiologists, who reached a consensus. Organomegaly was classified as severe, moderate or mild. On chest PA radiographs of 42 of the children, the transverse diameter of the trachea was measured and compared with that of 42 normal controls. Student's t test was used for statistical analysis. At abdominal CT, hepatomegaly was observed in 22 patients (92%; 2 severe, 15 moderate and 5 mild); and splenomegaly was present in 18 (75%; 2 severe, 4 moderate and 12 mild). Among eight patients(33%) with pancreatic enlargement, one had a severly enlarged pancreas, while in the remaining seven, enlargement was mild. Also present were inguinal hernia (n=15), umbilical hernia (n=12), undulation with thickening of the diaphragmatic crura (n=10), abnormalities related to the male genitalia (n=5) and vascular anomaly (n=3). In MPS patients, the mid-point diameter of the trachea (range, 5.6-9 mm; mean, 6.9 mm) was significantly less than in normal controls (range, 8-14 mm; mean, 10.8 mm) (p<0.001). An awareness of the characteristic abnormalities observed at abdominal CT and chest PA radiography can lead to a better understanding of MPS in children.

  19. Mucopolysaccharidosis: abnormal findings on abdomen and chest excluding musculoskeletal system

    Energy Technology Data Exchange (ETDEWEB)

    KimHan, Bo Kyung; Yoon, Hye Kyung; Cho, Jae Min [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Moon, Jeung Hee; Yoon, Dae Young; Seo, Young Lan; Han, Dae Hee; Choi, Chul Soon; Bae, Sang Hoon; Yoon, Young Cheol; Park, Sang Joon [Hallym University College of Medicine, Seoul (Korea, Republic of)

    2003-06-01

    Mucopolysaccharidosis (MPS) is a lysosomal storage disease that causes tissue distortion and dysfunction due to the infiltration of mucopolysaccharide in connective tissue. The purpose of this study was to evaluate the characteristic findings of abdominal CT and plain chest radiography in patients with MPS. Sixty-two children with MPS diagnosed by urine analysis were involved in this study; 24 of these underwent abdominal CT and the findings were reviewed by two radiologists, who reached a consensus. Organomegaly was classified as severe, moderate or mild. On chest PA radiographs of 42 of the children, the transverse diameter of the trachea was measured and compared with that of 42 normal controls. Student's t test was used for statistical analysis. At abdominal CT, hepatomegaly was observed in 22 patients (92%; 2 severe, 15 moderate and 5 mild); and splenomegaly was present in 18 (75%; 2 severe, 4 moderate and 12 mild). Among eight patients (33%) with pancreatic enlargement, one had a severly enlarged pancreas, while in the remaining seven, enlargement was mild. Also present were inguinal hernia (n=15), umbilical hernia (n=12), undulation with thickening of the diaphragmatic crura (n=10). abnormalities related to the male genitalia (n=5) and vascular anomaly (n=3). In MPS patients, the mid-point diameter of the trachea (range, 5.6-9 mm; mean, 6.9 mm) was significantly less than in normal controls (range, 8-14 mm; mean, 10.8 mm)(p<0.001). An awareness of the characteristic abnormalities observed at abdominal CT and chest PA radiography can lead to a better understanding of MPS in children.

  20. Novel computed tomographic chest metrics to detect pulmonary hypertension

    Directory of Open Access Journals (Sweden)

    Li Chin-Shang

    2011-03-01

    Full Text Available Abstract Background Early diagnosis of pulmonary hypertension (PH can potentially improve survival and quality of life. Detecting PH using echocardiography is often insensitive in subjects with lung fibrosis or hyperinflation. Right heart catheterization (RHC for the diagnosis of PH adds risk and expense due to its invasive nature. Pre-defined measurements utilizing computed tomography (CT of the chest may be an alternative non-invasive method of detecting PH. Methods This study retrospectively reviewed 101 acutely hospitalized inpatients with heterogeneous diagnoses, who consecutively underwent CT chest and RHC during the same admission. Two separate teams, each consisting of a radiologist and pulmonologist, blinded to clinical and RHC data, individually reviewed the chest CT's. Results Multiple regression analyses controlling for age, sex, ascending aortic diameter, body surface area, thoracic diameter and pulmonary wedge pressure showed that a main pulmonary artery (PA diameter ≥29 mm (odds ratio (OR = 4.8, right descending PA diameter ≥19 mm (OR = 7.0, true right descending PA diameter ≥ 16 mm (OR = 4.1, true left descending PA diameter ≥ 21 mm (OR = 15.5, right ventricular (RV free wall ≥ 6 mm (OR = 30.5, RV wall/left ventricular (LV wall ratio ≥0.32 (OR = 8.8, RV/LV lumen ratio ≥1.28 (OR = 28.8, main PA/ascending aorta ratio ≥0.84 (OR = 6.0 and main PA/descending aorta ratio ≥ 1.29 (OR = 5.7 were significant predictors of PH in this population of hospitalized patients. Conclusion This combination of easily measured CT-based metrics may, upon confirmatory studies, aid in the non-invasive detection of PH and hence in the determination of RHC candidacy in acutely hospitalized patients.