  1. The BRAHMS ring imaging Cherenkov detector

    Science.gov (United States)

    Debbe, R.; Jørgensen, C. E.; Olness, J.; Yin, Z.

    2007-01-01

    A Ring Imaging Cherenkov detector built for the BRAHMS experiment at the Brookhaven RHIC is described. This detector has a high index of refraction gas radiator. Cherenkov light is focused on a photo-multiplier based photon detector with a large spherical mirror. The combination of momentum and ring radius measurement provides particle identification from 2.5 to 35 GeV/ c for pions and kaons and well above 40 GeV/ c for protons during runs that had the radiator index of refraction set at n-1=1700×10-6.

  2. LHCb ring imaging Cherenkov detector mirrors

    CERN Multimedia

    Maximilien Brice

    2005-01-01

    In a large dark room, men in white move around an immense structure some 7 m high, 10 m wide and nearly 2.5 m deep. Apparently effortlessly, they are installing the two large high-precision spherical mirrors. These mirrors will focus Cherenkov light, created by the charged particles that will traverse this detector, onto the photon detectors.

  3. Particle Identification in Cherenkov Detectors using Convolutional Neural Networks

    CERN Document Server

    Theodore, Tomalty

    2016-01-01

    Cherenkov detectors are used for charged particle identification. When a charged particle moves through a medium faster than light can propagate in that medium, Cherenkov radiation is released in the shape of a cone in the direction of movement. The interior of the Cherenkov detector is instrumented with PMTs to detect this Cherenkov light. Particles, then, can be identified by the shapes of the images on the detector walls.

  4. Gadolinium study for a water Cherenkov detector

    CERN Document Server

    Kibayashi, Atsuko

    2009-01-01

    Modification of large water Cherenkov detectors by addition of gadolinium has been proposed. The large cross section for neutron capture on Gd will greatly improve the sensitivity to antielectron neutrinos from supernovae and reactors. A five-year project to build and develop a prototype detector based on Super-Kamiokande (SK) has started. We are performing various studies, including a material soak test in Gd solution, light attenuation length measurements, purification system development, and neutron tagging efficiency measurements using SK data and a Geant4-based simulation. We present an overview of the project and the recent R&D results.

  5. HAWC - The High Altitude Water Cherenkov Detector

    Science.gov (United States)

    Tepe, Andreas; HAWC Collaboration

    2012-07-01

    The high altitude water Cherenkov observatory (HAWC) is an instrument for the detection of high energy cosmic gamma-rays. Its predecessor Milagro has successfully proven that the water Cherenkov technology for gamma-ray astronomy is a useful technique. HAWC is currently under construction at Sierra Negra in Mexico at an altitude of 4100 m and will include several improvements compared to Milagro. Two complementary DAQ systems of the HAWC detector allow for the observation of a large fraction of the sky with a very high duty cycle and independent of environmental conditions. HAWC will observe the gamma-ray sky from about 100 GeV up to 100 TeV. Also the cosmic ray flux anisotropy on different angular length scales is object of HAWC science. Because of HAWC's large effective area and field of view, we describe its prospects to observe gamma-ray bursts (GRBs) as an example for transient sources.

  6. Background radiation measurement with water Cherenkov detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bertou, X., E-mail: bertou@cab.cnea.gov.a [CONICET/CNEA, Centro Atomico Bariloche (Argentina); Observatorio Pierre Auger, Av. San Martin Norte 304, 5613 Malarguee (Argentina)

    2011-05-21

    Water Cherenkov Detectors have the nice property of being mostly calorimeters for cosmic ray induced electrons and photons, while providing a clear signal for muons. At large energy deposited in the detector, they observe small extended air showers. This makes them interesting detectors to study the background of cosmic ray secondaries. Using low threshold scaler counters, one can follow the flux of cosmic rays on top of the atmosphere, and/or study atmospheric effects on the cosmic ray shower development. In this paper, background data from the Pierre Auger Observatory are presented. These data are searched for short time-scale variation (one second scale, as expected from Gamma Ray Bursts), and larger time-scale variations, showing modulation effects due to Solar activity (Forbush decreases). Rapid changes in the background flux are also observed during the crossing of storms over the 3000 km{sup 2} of the ground array.

  7. The Ring Imaging Cherenkov Detectors for LHCb

    CERN Document Server

    Papanestis, Antonis

    2005-01-01

    The success of the LHCb experiment depends heavily on particle identification over the momentum 2-100 GeV/c. To meet this challenge, LHCb uses a Ring Imaging Cherenkov (RICH) system composed of two detectors with three radiators. RICH1 has both aerogel and gas (C$_4$F$_{10}$) radiators, while RICH2 has only a gas (CF$_4$) radiator. The design of RICH1 is almost complete, whereas RICH2 has been constructed and installed (Nov 2005). Novel Hybrid Photon Detectors (HPDs) have been developed in collaboration with industry to detect the Cherenkov photons. A silicon pixel detector bump-bonded to a readout chip is encapsulated in a vacuum tube. A bi-alkali photocathode is deposited on the inside of the quartz entrance window to convert photons in the range 200-600 nm. The pixel chip is manufactured in 0.25 $\\mu$m deep-submicron radiation-tolerant technology and consists of 1024 logical pixels, each pixel having an area of 0.5 mm x 05. Mm. Photo-electrons are accelerated by a 20kV potential, resulting in a signal of ...

  8. First observation of Cherenkov ring images using hybrid photon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, E.; Wilkinson, G. [European Organization for Nuclear Research, Geneva (Switzerland). Div. Particle Physics Experiments; Barber, G.; Duane, A.; John, M.; Miller, D.G.; Websdale, D. [Imperial College of Science Technology and Medicine, Blackett Laboratory, Prince Consort Road, London SW7 2AZ (United Kingdom); Bibby, J.H.; Giles, R.; Harnew, N.; Smale, N. [University of Oxford, Department of Nuclear Physics, Keble Road, Oxford OX1 3RH (United Kingdom); Brook, N.H.; Halley, A.W.; O`Shea, V. [University of Glasgow, Department of Physics, Glasgow G12 8QQ (United Kingdom); French, M. [Rutherford Appleton Laboratory, Chilton, Didcot, Oxon OX11 0QX (United Kingdom); Gibson, V.; Wotton, S.A. [University of Cambridge, Cavendish Laboratory, Madingley Road, Cambridge CB3 0HE (United Kingdom); Schomaker, R. [Delft Electronic Products BV, 9300 AB Roden (Netherlands)

    1998-07-11

    A ring-imaging Cherenkov detector, equipped with hybrid photon detectors, has been operated in a charged-particle beam. Focussed ring images from various particle types were detected using silica aerogel, air and C{sub 4}F{sub 10} gas radiators. The detector, a prototype for the CERN LHC-B experiment, is described and first observations are reported. (orig.)

  9. Particle Identification: Time-of-Flight, Cherenkov and Transition Radiation Detectors - Particle Detectors and Detector Systems

    CERN Document Server

    Ullaland, O

    2011-01-01

    Particle Identification: Time-of-Flight, Cherenkov and Transition Radiation Detectors in 'Particle Detectors and Detector Systems', part of 'Landolt-Börnstein - Group I Elementary Particles, Nuclei and Atoms: Numerical Data and Functional Relationships in Science and Technology, Volume 21B1: Detectors for Particles and Radiation. Part 1: Principles and Methods'. This document is part of Part 1 'Principles and Methods' of Subvolume B 'Detectors for Particles and Radiation' of Volume 21 'Elementary Particles' of Landolt-Börnstein - Group I 'Elementary Particles, Nuclei and Atoms'. It contains the Section '3.3 Particle Identification: Time-of-Flight, Cherenkov and Transition Radiation Detectors' of Chapter '3 Particle Detectors and Detector Systems' with the content: 3.3 Particle Identification: Time-of-Flight, Cherenkov and Transition Radiation Detectors 3.3.1 Introduction 3.3.2 Time of Flight Measurements 3.3.2.1 Scintillator hodoscopes 3.3.2.2 Parallel plate ToF detectors 3.3.3 Cherenkov Radiation 3.3.3.1 ...

  10. Research and Development for a Gadolinium Doped Water Cherenkov Detector

    CERN Document Server

    Renshaw, Andrew

    2012-01-01

    The proposed introduction of a soluble gadolinium (Gd) compound into water Cherenkov detectors can result in a high efficiency for the detection of free neutrons capturing on the Gd. The delayed 8 MeV gamma cascades produced by these captures, in coincidence with a prompt positron signal, serve to uniquely identify electron antineutrinos interacting via inverse beta decay. Such coincidence detection can reduce backgrounds, allowing a large Gd-enhanced water Cherenkov detector to make the first observation of supernova relic neutrinos and high precision measurements of Japan's reactor antineutrino flux, while still allowing for all current physics studies to be continued. Now, a dedicated Gd test facility is operating in the Kamioka Mine. This new facility houses everything needed to successfully operate a Gd doped water Cherenkov detector. Successful running of this facility will demonstrate that adding Gd salt to SK is both safe for the detector and is capable of delivering the expected physics benefits.

  11. Light-weight spherical mirrors for Cherenkov detectors

    CERN Document Server

    Cisbani, E; Colilli, S; Crateri, R; Cusanno, F; De Leo, R; Fratoni, R; Frullani, S; Garibaldi, F; Giuliani, F; Gricia, M; Iodice, M; Iommi, R; Lagamba, L; Lucentini, M; Mostarda, A; Nappi, E; Pierangeli, L; Santavenere, F; Urciuoli, G M; Vernin, P

    2003-01-01

    Light-weight spherical mirrors have been appositely designed and built for the gas threshold Cherenkov detectors of the two Hall A spectrometers. The mirrors are made of a 1 mm thick aluminized plexiglass sheet, reinforced by a rigid backing consisting of a phenolic honeycomb sandwiched between two carbon fiber mats epoxy glued. The produced mirrors have a thickness equivalent to 0.55% of radiation length, and an optical slope error of about 5.5 mrad. These characteristics make these mirrors suitable for the implementation in Cherenkov threshold detectors. Ways to improve the mirror features are also discussed in view of their possible employment in RICH detectors.

  12. Long term biological developments in water Cherenkov detector media

    Energy Technology Data Exchange (ETDEWEB)

    Venturini, M. [Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Filevich, A., E-mail: filevich@tandar.cnea.gov.ar [Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Pizarro, R.; Ibanez, J. [Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Bauleo, P. [Fort Collins, CO (United States); Rodriguez Martino, J. [Pierre Auger Observatory, Malarguee, Mendoza (Argentina)

    2011-12-11

    Fourteen years ago, studies on bacteria growing in clean water were made in order to assess the hazard imposed by a possible expansion of bacteria population in the water tanks of the Pierre Auger Observatory Cherenkov detectors. In 1999 TANGO Array, a reduced-size unitary cell, composed of four water Cherenkov detectors, was constructed at the TANDAR campus of the Atomic Energy Commission, in Buenos Aires, to be used as a working model of the proposed surface array. TANGO Array ran for one year observing energy, intensity, and arrival directions of cosmic rays at sea level. Nine years after it was decommissioned, the water tanks configuring the Cherenkov detectors are still kept closed. In May 2009 water and liner samples from these tanks were collected to determine eventual long term bacteria growth in the internal detector environment, which is very similar to those of the detectors installed in the Malarguee Site. In the present note we report the results of the bacteriological study performed on the samples obtained from the TANGO Array detector tanks. Cultivable, long time surviving, bacterial species were identified, both in the water mass and on the liner surface, and the light transmission in water at the relevant Cherenkov wavelength was studied. An upper limit of possible interferences caused by bacteria is estimated.

  13. The Ring Imaging CHerenkov Detectors of the LHCb Experiment

    CERN Document Server

    Perego, Davide Luigi

    2012-01-01

    Particle identification is a fundamental requirement of the LHCb experiment to fulfill its physics programme. Positive hadron identification is performed by two Ring Imaging CHerenkov (RICH) detectors. This system covers the full angular acceptance of the experiment and is equipped with three Cherenkov radiators to identify particles in a wide momentum range from1 GeV/ c up to 100 GeV/ c . The Hybrid Photon Detectors (HPDs) located outside the detector acceptance provide the photon detection with 500,000 channels. Specific read–out electronics has been developed to readout and process data from the HPDs including data transmission and power distribution. The operation and performanceoftheRICHsystemare ensuredbythe constant controland monitoringoflowandhighvoltage systems,of thegas qualityandenvironmental parameters,ofthe mirror alignment,and finallyofthe detector safety. The description of the LHCb RICH is given. The experience in operating the detector at the Large Hadron Collider is presented and discusse...

  14. A Cherenkov Radiation Detector with High Density Aerogels

    CERN Document Server

    Cremaldi, Lucien; Sonnek, Peter; Summers, Donald J; Reidy, Jim

    2009-01-01

    We have designed a threshold Cherenkov detector at the Rutherford-Appleton Laboratory to identify muons with momenta between 230 and 350 MeV/c. We investigated the properties of three aerogels for the design. The nominal indexes of refraction were n = 1.03, 1.07, 1.12, respectively. Two of the samples are of high density aerogel not commonly used for Cherenkov light detection. We present results of an examination of some optical properties of the aerogel samples and present basic test beam results.

  15. Cherenkov Detector for Beam Quality Measurement

    CERN Document Server

    Orfanelli, Stella

    2015-01-01

    A new detector to measure the machine induced background at larger radiihas been developed and installed in the CMS experiment at LHC. Itconsists of 40 modules, each comprising a quartz bar read out by aphotomultiplier. Since Cerenkov radiation is emitted in a forward conearound the charged particle trajectory, these detectors can distinguishthe directions of the machine induced background.The back-end consists of a microTCA readout with excellent time resolution.The performance of the detector modules measured in several test-beamcampaigns will be reported. The installation in CMS will be described, andfirst results about operating the detector during data taking will begiven.

  16. Spectrum of energy depositions in the Auger Water Cherenkov Detector

    Science.gov (United States)

    Salazar, Humberto

    1999-08-01

    The measured spectrum of energy depositions in a Water Cherenkov Detector (WCD) prototype for the Pierre Auger Observatory is presented. A WCD (area 10 m2 )is located in the Puebla University campus at a depth of 800 g/cm2 (2200 m above sea level). Differential and integral spectra in a wide energy deposition range (0.5 - 150 of vertical equivalent muons) are presented. The problem of the WCD "self calibration" procedure (by rate of the muon events) is discussed. The characteristic change of the slopes of the differential spectrum at the transition from single muon signals to EAS signals is also discussed. The measured energy deposition spectrum at extreme signals is used to estimate the linearity of the response of the WCD PMTs. Key words: Auger array, water Cherenkov detector, extensive air showers

  17. Performance test of wavelength-shifting acrylic plastic Cherenkov detector

    CERN Document Server

    Beckford, B; de la Puente, A; Fuji, Y; Futatsukawa, K; Hashimoto, O; Kaneta, M; Kanda, H; Koike, T; Maeda, K; Matsumura, A; Nakamura, S N; Okayasu, Y; Perez, N; Reinhold, J; Shirotori, K; Tamura, H; Tang, L; Tsukada, K

    2010-01-01

    The collection efficiency for Cherenkov light incident on a wavelength shifting plate (WLS) has been determined during a beam test at the Proton Synchrotron facility located in the National Laboratory for High Energy Physics (KEK), Tsukuba, Japan. The experiment was conducted in order to determine the detector's response to photoelectrons converted from photons produced by a fused silica radiator; this allows for an approximation of the detector's quality. The yield of the photoelectrons was measured as a function of the momentum of the incident hadron beam. The yield is proportional to sin2{\\theta}c, where {\\theta}c is the opening angle of the Cherenkov light created. Based on estimations and results from similarly conducted tests, where the collection efficiency was roughly 39%, the experimental result was expected to be around 40% for internally produced light from the WLS. The results of the experiment determined the photon collection response efficiency of the WLS to be roughly 62% for photons created in...

  18. Calibration of pressure gauge for Cherenkov detector

    CERN Document Server

    Saponjic, Nevena

    2013-01-01

    Solartron/Hamilton pressure gauges are used to monitor the gas pressure in the particle beam detectors installed in the experimental areas. Here is description of the test bench for the calibration of these gauges in Labview.

  19. The Ring Imaging Cherenkov detector (RICH) of the AMS experiment

    CERN Document Server

    Barão, F; Alcaraz, J; Arruda, L; Barrau, A; Barreira, G; Belmont, E; Berdugo, J; Brinet, M; Buénerd, M; Casadei, D; Casaus, J; Cortina, E; Delgado, C; Díaz, C; Derome, L; Eraud, L; Garcia-Lopez, R J; Gallin-Martel, L; Giovacchini, F; Gonçalves, P; Lanciotti, E; Laurenti, G; Malinine, A; Maña, C; Marin, J; Martínez, G; Menchaca-Rocha, A; Molla, M; Palomares, C; Panniello, M; Pereira, R; Pimenta, M; Protasov, K; Sánchez, E; Seo, E S; Sevilla, N; Torrento, A; Vargas-Trevino, M; Veziant, O

    2006-01-01

    The Alpha Magnetic Spectrometer (AMS) experiment to be installed on the International Space Station (ISS) will be equipped with a proximity focusing Ring Imaging Cherenkov (RICH) detector for measuring the electric charge and velocity of the charged cosmic particles. A RICH prototype consisting of 96 photomultiplier units, including a piece of the conical reflector, was built and its performance evaluated with ion beam data. Preliminary results of the in-beam tests performed with ion fragments resulting from collisions of a 158 GeV/c/nuc primary beam of Indium ions (CERN SPS) on a Pb target are reported. The collected data included tests to the final front-end electronics and to different aerogel radiators. Cherenkov rings for a large range of charged nuclei and with reflected photons were observed. The data analysis confirms the design goals. Charge separation up to Fe and velocity resolution of the order of 0.1% for singly charged particles are obtained.

  20. The HERMES dual-radiator ring imaging Cherenkov detector

    Science.gov (United States)

    Akopov, N.; Aschenauer, E. C.; Bailey, K.; Bernreuther, S.; Bianchi, N.; Capitani, G. P.; Carter, P.; Cisbani, E.; De Leo, R.; De Sanctis, E.; De Schepper, D.; Djordjadze, V.; Filippone, B. W.; Frullani, S.; Garibaldi, F.; Hansen, J.-O.; Hommez, B.; Iodice, M.; Jackson, H. E.; Jung, P.; Kaiser, R.; Kanesaka, J.; Kowalczyk, R.; Lagamba, L.; Maas, A.; Muccifora, V.; Nappi, E.; Negodaeva, K.; Nowak, W.-D.; O'Connor, T.; O'Neill, T. G.; Potterveld, D. H.; Ryckbosch, D.; Sakemi, Y.; Sato, F.; Schwind, A.; Shibata, T.-A.; Suetsugu, K.; Thomas, E.; Tytgat, M.; Urciuoli, G. M.; Van de Kerckhove, K.; Van de Vyver, R.; Yoneyama, S.; Zohrabian, H.; Zhang, L. F.

    2002-03-01

    The construction and use of a dual radiator Ring Imaging Cherenkov (RICH) detector is described. This instrument was developed for the HERMES experiment at DESY which emphasises measurements of semi-inclusive deep-inelastic scattering. It provides particle identification for pions, kaons, and protons in the momentum range from 2 to 15 GeV, which is essential to these studies. The instrument uses two radiators, C 4F 10, a heavy fluorocarbon gas, and a wall of silica aerogel tiles. The use of aerogel in a RICH detector has only recently become possible with the development of clear, large, homogeneous and hydrophobic aerogel. A lightweight mirror was constructed using a newly perfected technique to make resin-coated carbon-fiber surfaces of optical quality. The photon detector consists of 1934 photomultiplier tubes (PMT) for each detector half, held in a soft steel matrix to provide shielding against the residual field of the main spectrometer magnet.

  1. The HERMES dual-radiator ring imaging Cherenkov detector

    CERN Document Server

    Akopov, N; Bailey, K; Bernreuther, S; Bianchi, N; Capitani, G P; Carter, P; Cisbani, E; De Leo, R; De Sanctis, E; De Schepper, D; Dzhordzhadze, V; Filippone, B W; Frullani, S; Garibaldi, F; Hansen, J O; Hommez, B; Iodice, M; Jackson, H E; Jung, P; Kaiser, R; Kanesaka, J; Kowalczyk, R; Lagamba, L; Maas, A; Muccifora, V; Nappi, E; Negodaeva, K; Nowak, Wolf-Dieter; O'Connor, T; O'Neill, T G; Potterveld, D H; Ryckbosch, D; Sakemi, Y; Sato, F; Schwind, A; Shibata, T A; Suetsugu, K; Thomas, E; Tytgat, M; Urciuoli, G M; Van De Kerckhove, K; Van De Vyver, R; Yoneyama, S; Zhang, L F; Zohrabyan, H G

    2002-01-01

    The construction and use of a dual radiator Ring Imaging Cherenkov (RICH) detector is described. This instrument was developed for the HERMES experiment at DESY which emphasises measurements of semi-inclusive deep-inelastic scattering. It provides particle identification for pions, kaons, and protons in the momentum range from 2 to 15 GeV, which is essential to these studies. The instrument uses two radiators, C sub 4 F sub 1 sub 0 , a heavy fluorocarbon gas, and a wall of silica aerogel tiles. The use of aerogel in a RICH detector has only recently become possible with the development of clear, large, homogeneous and hydrophobic aerogel. A lightweight mirror was constructed using a newly perfected technique to make resin-coated carbon-fiber surfaces of optical quality. The photon detector consists of 1934 photomultiplier tubes (PMT) for each detector half, held in a soft steel matrix to provide shielding against the residual field of the main spectrometer magnet.

  2. The Cherenkov Surface Detector of the Pierre Auger Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Billoir, Pierre, E-mail: billoir@lpnhe.in2p3.fr [LPNHE, CNRS/IN2P3 and Univ. P. and M. Curie and Univ. D. Diderot, 4 place Jussieu 75272 Paris Cedex 05 (France); Observatorio Pierre Auger, av. San Martín Norte, 304 5613, Malargüe (Argentina)

    2014-12-01

    The Pierre Auger Observatory detects the atmospheric showers induced by cosmic rays of ultra-high energy (UHE). It is the first one to use the hybrid technique. A set of telescopes observes the fluorescence of the nitrogen molecules on clear moonless nights, giving access to the longitudinal profile of the shower. These telescopes surround a giant array of 1600 water Cherenkov tanks (covering more than 3000 km{sup 2}), which works continuously and samples the particles reaching the ground (mainly muons, photons and electrons/positrons); the light produced within the water is recorded into FADC (Fast Analog to Digital Convertes) traces. A subsample of hybrid events provides a cross calibration of the two components. We describe the structure of the Cherenkov detectors, their sensitivity to different particles and the information they can give on the direction of origin, the energy and the nature of the primary UHE object; we discuss also their discrimination power for rare events (UHE photons or neutrinos). To cope with the variability of weather conditions and the limitations of the communication system, the procedures for trigger and real time calibration have been shared between local processors and a central acquisition system. The overall system has been working almost continuously for 10 years, while being progressively completed and increased by the creation of a dense “infill” subarray. - Highlights: • The water Cherenkov technique is used in the Surface Detector of the Pierre Auger Observatory. • Cross-calibrated with the Fluorescence Detector, it provides a measurement of the primary energy. • The spectrum of the UHE cosmic rays exhibits clearly an “ankle” and a cutoff. • The muon observed muon content of the atmospheric showers is larger than expected from the models. • Stringent limits on the flux of UHE neutrinos and photons are obtained.

  3. Application of Geiger-mode photosensors in Cherenkov detectors

    Energy Technology Data Exchange (ETDEWEB)

    Gamal, Ahmed, E-mail: gamal.ahmed@assoc.oeaw.ac.a [Stefan Meyer Institute for Subatomic Physics of the Austrian Academy of Sciences, Vienna (Austria); Al-Azhar University, Faculty of Science, Physics Department, Cairo (Egypt); Paul, Buehler; Michael, Cargnelli [Stefan Meyer Institute for Subatomic Physics of the Austrian Academy of Sciences, Vienna (Austria); Roland, Hohler [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Johann, Marton [Stefan Meyer Institute for Subatomic Physics of the Austrian Academy of Sciences, Vienna (Austria); Herbert, Orth [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Ken, Suzuki [Stefan Meyer Institute for Subatomic Physics of the Austrian Academy of Sciences, Vienna (Austria)

    2011-05-21

    Silicon-based photosensors (SiPMs) working in the Geiger-mode represent an elegant solution for the readout of particle detectors working at low-light levels like Cherenkov detectors. Especially the insensitivity to magnetic fields makes this kind of sensors suitable for modern detector systems in subatomic physics which are usually employing magnets for momentum resolution. We are characterizing SiPMs of different manufacturers for selecting sensors and finding optimum operating conditions for given applications. Recently we designed and built a light concentrator prototype with 8x8 cells to increase the active photon detection area of an 8x8 SiPM (Hamamatsu MPPC S10931-100P) array. Monte Carlo studies, measurements of the collection efficiency, and tests with the MPPC were carried out. The status of these developments are presented.

  4. Application of Geiger-mode photo sensors in Cherenkov detectors

    CERN Document Server

    Ahmed, Gamal; Cargnelli, Michael; Hohler, Roland; Marton, Johann; Orth, Herbert; Suzuki, Ken

    2010-01-01

    Silicon-based photosensors (SiPMs) working in the Geiger-mode represent an elegant solution for the readout of particle detectors working at low-light levels like Cherenkov detectors. Especially the insensitivity to magnetic fields makes this kind of sensors suitable for modern detector systems in subatomic physics which are usually employing magnets for momentum resolution. In our institute we are characterizing SiPMs of different manufacturers for selecting sensors and finding optimum operating conditions for given applications. Recently we designed and built a light concentrator prototype with 8x8 cells to increase the active photon detection area of an 8x8 SiPM (Hamamatsu MPPC S10931-100P) array. Monte Carlo studies, measurements of the collection efficiency, and tests with the MPPC were carried out. The status of these developments are presented.

  5. Large acceptance forward Cherenkov detector for the BRAHMS experiment at RHIC

    Science.gov (United States)

    Budick, B.; Beavis, D.; Chasman, C.

    2010-09-01

    A multi-element detector based on Cherenkov radiation in plastic and on photomultiplier tubes has been constructed that is particularly useful in collider experiments. The detector covers the pseudorapidity interval 3.23BRAHMS.

  6. Signal Temporal Profile of a Water Cherenkov Detector

    Science.gov (United States)

    Salazar, H.; Martinez, O.; Cotzomi, J.; Moreno, E.; Villaseñor, L.

    2003-07-01

    The suggested existence of temporal structure in the signals of extensive air showers (EAS) for energies greater than 1017 eV at core distances of about 500 m, and its correlation with important parameters of EASs has stimulated us to study this structure for showers with lower energies in an Auger water Cherenkov detector(WCD). Preliminary analysis of experimental data on the widths of signals in a WCD and their correlation with other parameters of the signal are presented. The detector was triggered by the EAS-BUAP array which operates in the region of 1014 - 1016 eV. The distance of the WCD to the EAS core is larger than 30 m.

  7. Development of ring imaging Cherenkov detectors for the LHCb experiment

    CERN Document Server

    John, M J J

    2001-01-01

    This thesis reports on work done as part of the development of the Ring Imaging Cherenkov (RICH) detectors of the LHCb experiment. The context of this work is set out in Chapter 1, which includes an overview of the physics of CP violation, followed by a discussion of other experiments that study B physics. LHCb itself is then described, with particular emphasis on its RICH detectors, and the photon detectors to be used therein. The work done by the author to ensure an adequate shielding of the photon detectors in the two RICH detectors from the magnetic fields produced by the LHCb dipole is then presented. A candidate photodetector for the RICH is the Pixel HPD. The author's contribution to the upgrade of the HPD test system to operate at the LHC bunch-crossing rate of 40MHz is the subject of the following section. This system was used to investigate and optimise a method of minimising the threshold distribution of the Pixel HPD's encapsulated readout chip. The final chapter of the thesis concerns the aerogel...

  8. Optical properties of water for the Yangbajing water cherenkov detector

    Science.gov (United States)

    Gao, Shang-qi; Sun, Zhi-bin; Jiang, Yuan-da; Wang, Chao; Du, Ke-ming

    2011-08-01

    Cherenkov radiation is used to study the production of particles during collisions, cosmic rays detections and distinguishing between different types of neutrinos and electrons. The optical properties of water are very important to the research of Cherenkov Effect. Lambert-beer law is a method to study the attenuation of light through medium. In this paper, optical properties of water are investigated by use of a water attenuation performance test system. The system is composed of the light-emitting diode (LED) light source and the photon receiver models. The LED light source model provides a pulse light signal which frequency is 1 kHz and width is 100ns. In photon receiver model, a high sensitivity photomultiplier tube (PMT) is used to detect the photons across the water. Because the output voltage amplitude of PMT is weak which is from 80mv to 120mV, a low noise pre-amplifier is used to improve the detector precise. An effective detector maximum time window of PMT is 100ns for a long lifetime, so a peak holder circuit is used to hold the maximum peak amplitude of PMT for the induced photons signal before the digitalization. In order to reduce the noise of peak holder, a multi-pulse integration is used before the sampling of analog to digital converter. At last, the detector of photons from the light source to the PMT across the water is synchronized to the pulse width of the LED. In order to calculate the attenuation coefficient and attenuation length of water precisely, the attenuation properties of air-to-water boundary is considered in the calculation.

  9. Development of a gaseous photon detector for Cherenkov imaging applications

    CERN Document Server

    Rocco, Elena; Dalla Torre, Silvia

    2010-01-01

    This thesis is dedicated to the R&D activity aiming at a novel micro pattern gaseous photon detector based on the THick Gas Electron Multiplier (THGEM). The goal application of the novel photon detector is the detection of single photon in Ring Imaging CHerenkov (RICH) counters. The THGEM principle is derived from the Gas Electron Multiplier (GEM) one, even if the material, the production technology and the size scale are different: a THGEM is a Circuit Printed Board (PCB) coated with thin copper layers on both faces, with holes obtained by drilling. Part of the THGEM features are similar to those of the GEMs, but a number of characteristics aspects result substantially different: in fact, if the geometrical parameters can be scaled from the GEM ones, the parameters related to the electrons multiplication, which is a microscopic physical phenomenon, do not. This is why, before starting the photon detector development, we have performed a systematic study of the THGEM multiplier. A photon detector is forme...

  10. WIMP search and a Cherenkov detector prototype for ILC polarimetry

    Energy Technology Data Exchange (ETDEWEB)

    Bartels, Christoph

    2011-10-15

    The planned International Linear Collider (ILC) will be an essential experiment to precisely determine the properties and structure of physics at the TeV scale. An important feature of the ILC is the possibility to use polarized electrons and positrons. In part 1 of this thesis, a model independent search for Weakly Interacting Massive Particles (WIMPs) at ILC is presented. The signal channel under study is direct WIMP pair production with associated Initial State Radiation (ISR), e{sup +}e{sup -} {yields} {chi}{chi}{gamma}, where the WIMPs leave the detector without any further interaction, and only the emitted photon is detected. From the energy spectrum of the detected photons the coupling structure, cross sections, masses and the quantum number of the dominant partial wave in the production process can be inferred. The analysis includes the dominant SM, as well as machine-induced backgrounds, and is performed using a full simulation of the ILD detector concept. For an integrated luminosity of L=500 fb{sup -1}, the signal cross sections can be measured to a precision of 3%, dominated by systematic uncertainties on the polarization measurement of the initial electrons and positrons. Masses can be measured to a precision of up to 2% by a comparison of the data photon spectrum to parametrized template spectra. In part 2 of this thesis, a Cherenkov detector prototype for Compton polarimetry at ILC is presented. For the polarization measurement a systematic uncertainty of {delta} P/P = 0.25% or better is envisioned. To achieve this goal, the Cherenkov detector has to be precisely aligned with the fan of Compton scattered electrons and its signal response needs to be highly linear. For the detector prototype data driven alignment strategies have been developed by comparing data recorded at the Elsa accelerator in Bonn, Germany, with detailed Geant4 simulations. With the use of multi-anode photomultipliers, data driven alignment strategies promise to provide the

  11. TORCH - a Cherenkov-based time-of-flight detector

    CERN Document Server

    van Dijk, M W U; Cowie, E N; Cussans, D; D' Ambrosio, C; Forty, R; Frei, C; Gys, T; Piedigrossi, D; Castillo Garcia, L; Fopma, J; Gao, R; Harnew, N; Keri, T

    2014-01-01

    TORCH is an innovative high-precision time-of-flight system to provide particle identification in the difficult intermediate momentum region up to 10 GeV/c. It is also suitable for large-area applications. The detector provides a time-of-flight measurement from the imaging of Cherenkov photons emitted in a 1 cm thick quartz radiator. The photons propagate by total internal reflection to the edge of the quartz plate, where they are focused onto an array of photon detectors at the periphery. A time-of-flight resolution of about 10–15 ps per incident charged particle needs to be achieved for a three sigma kaon–pion separation up to 10 GeV/c momentum for the TORCH located 9.5 m from the interaction point. Given ∼ 30 detected photons per incident charged particle, this requires measuring the time-of-arrival of individual photons to about 70 ps. This paper will describe the design of a TORCH prototype involving a number of ground-breaking and challenging techniques.

  12. Development of Ring Imaging Cherenkov Detectors for LHCb

    CERN Document Server

    Bellunato, T; Matteuzzi, C

    2003-01-01

    The work described in this thesis has been carried out in the framework of the development program of the Ring Imaging Cherenkov (RICH) detectors of the LHCb experiment. LHCb will operate at the Large Hadron Collider at CERN, and it will perform a wide range of measurements in the b-hadrons realm. The extensive study of CP violation and rare decays in the b-hadron system are the main goals of the experiment. An introduction to CP violation in hadronic interactions is given in chapter 1. The high b-b bar production cross section at the LHC energy will provide an unprecedented amount of data which will give LHCb a unique opportunity for precision tests on a large set of physics channels as well as a promising discovery potential for sources of CP violation arising from physics beyond the Standard Model. The experiment is designed in such a way to optimally match the kinematic structure of events where a pair of b quarks is produced in the collision between to 7 GeV protons. Chapter 2 is devoted to an overview o...

  13. Cherenkov detectors for spatial imaging applications using discrete-energy photons

    Science.gov (United States)

    Rose, Paul B.; Erickson, Anna S.

    2016-08-01

    Cherenkov detectors can offer a significant advantage in spatial imaging applications when excellent timing response, low noise and cross talk, large area coverage, and the ability to operate in magnetic fields are required. We show that an array of Cherenkov detectors with crude energy resolution coupled with monochromatic photons resulting from a low-energy nuclear reaction can be used to produce a sharp image of material while providing large and inexpensive detector coverage. The analysis of the detector response to relative transmission of photons with various energies allows for reconstruction of material's effective atomic number further aiding in high-Z material identification.

  14. A Quartz Cherenkov Detector for Compton-Polarimetry at Future e+e- Colliders

    CERN Document Server

    List, Jenny; Vormwald, Benedikt

    2015-01-01

    Precision polarimetry is essential for future e+ e- colliders and requires Compton polarimeters designed for negligible statistical uncertainties. In this paper, we discuss the design and construction of a quartz Cherenkov detector for such Compton polarimeters. The detector concept has been developed with regard to the main systematic uncertainties of the polarisation measurements, namely the linearity of the detector response and detector alignment. Simulation studies presented here imply that the light yield reachable by using quartz as Cherenkov medium allows to resolve in the Cherenkov photon spectra individual peaks corresponding to different numbers of Compton electrons. The benefits of the application of a detector with such single-peak resolution to the polarisation measurement are shown for the example of the upstream polarimeters foreseen at the International Linear Collider. Results of a first testbeam campaign with a four-channel prototype confirming simulation predictions for single electrons ar...

  15. Cherenkov angle and charge reconstruction with the RICH detector of the AMS experiment

    CERN Document Server

    Barão, F; Borges, J; Gonçalves, P; Pimenta, M; Pérez, I

    2003-01-01

    The Alpha Magnetic Spectrometer experiment to be installed on the International Space Station will be equipped with a proximity focusing Ring Imaging Cherenkov (RICH) detector, for measurements of particle electric charge and velocity. In this note, two possible methods for reconstructing the Cherenkov angle and the electric charge with the RICH are discussed. A Likelihood method for the Cherenkov angle reconstruction was applied leading to a velocity determination for protons with a resolution of around 0.1%. The existence of a large fraction of background photons which can vary from event to event implied a charge reconstruction method based on an overall efficiency estimation on an event-by-event basis.

  16. Features and performance of a large gas Cherenkov detector with threshold regulation

    Energy Technology Data Exchange (ETDEWEB)

    Alberdi, J.; Alvarez-Taviel, J.; Asenjo, L.; Colino, N.; Diez-Hedo. F.; Duran, I.; Gonzalez, J.; Hernandez, J.J.; Ladron de Guevara, P.; Marquina, M.A.

    1988-01-15

    We present here the development, main features and calibration procedures for a new type of gas Cherenkov detector, based upon the ability to control its threshold by regulating the temperature of the gas used as radiator. We also include the performance of this detector in particle identification.

  17. Electrostatic design of the barrel CRID (Cherenkov Ring Imaging Detector) and associated measurements

    Energy Technology Data Exchange (ETDEWEB)

    Abe, K.; Hasegawa, K.; Suekane, F.; Yuta, H. (Tohoku Univ., Sendai (Japan). Dept. of Physics); Antilogus, P.; Aston, D.; Bienz, T.; Bird, F.; Dunwoodie, W.; Hallewell, G.; Kawahara, H.; Kwon, Y.; Leith, D.W.G.S.; Muller, D.; Nagamine, T.; Pavel, T.; Ratcliff, B.; Rensing, P.; Schultz, D.; Shapiro, S.; Simopoulos, C.; Solodov, E.; Toge, N.; Va' Vra, J. Williams, H. (Stanford Linear Accelerator Center, Menlo Park, CA (US

    1990-04-01

    We report on the electrostatic design and related measurements of the barrel Cherenkov Ring Imaging Detector for the Stanford Large Detector experiment at the Stanford Linear Accelerator Center Linear Collider. We include test results of photon feedback in TMAE-laden gas, distortion measurements in the drift boxes and corona measurements. 13 refs., 21 figs.

  18. CHerenkov detectors In mine PitS (CHIPS) Letter of Intent to FNAL

    CERN Document Server

    Adamson, P; Davies, G S; Evans, J J; Guzowski, P; Habig, A; Hartnell, J; Holin, A; Huang, J; Kreymer, A; Kordosky, M; Lang, K; Marshak, M L; Mehdiyev, R; Meier, J; Miller, W; Naples, D; Nelson, J K; Nichol, R J; Patterson, R B; Perch, A; Pfutzner, M; Proga, M; Radovic, A; Sanchez, M C; Schreiner, S; Soldner-Rembold, S; Sousa, A; Thomas, J; Vahle, P; Wendt, C; Whitehead, L H; Wojcicki, S

    2013-01-01

    This Letter of Intent outlines a proposal to build a large, yet cost-effective, 100 kton fiducial mass water Cherenkov detector that will initially run in the NuMI beam line. The CHIPS detector (CHerenkov detector In Mine PitS) will be deployed in a flooded mine pit, removing the necessity and expense of a substantial external structure capable of supporting a large detector mass. There are a number of mine pits in northern Minnesota along the NuMI beam that could be used to deploy such a detector. In particular, the Wentworth Pit 2W is at the ideal off-axis angle to contribute to the measurement of the CP violating phase. The detector is designed so that it can be moved to a mine pit in the LBNE beam line once that becomes operational.

  19. CHerenkov detectors In mine PitS (CHIPS) Letter of Intent to FNAL

    Energy Technology Data Exchange (ETDEWEB)

    Adamson, P. [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States); Austin, J. [Univ. of Minnesota, Duluth, MN (United States); Cao, S. V. [Univ. of Texas, Austin, TX (United States); Coelho, J. A. B. [Tufts Univ., Medford, MA (United States); Davies, G. S. [Iowa State Univ., Ames, IA (United States); Evans, J. J. [Univ. of Manchester (United Kingdom); Guzowski, P. [Univ. of Manchester (United Kingdom); Habig, A. [Univ. of Minnesota, Duluth, MN (United States); Holin, A. [Univ. College London, London (United Kingdom); Huang, J. [Univ. of Texas, Austin, TX (United States); Johnson, R. [Univ. of Cincinnati, OH (United States); St. John, J. [Univ. of Cincinnati, OH (United States); Kreymer, A. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Kordosky, M. [College of William and Mary, Williamsburg, VA (United States); Lang, K. [Univ. of Texas, Austin, TX (United States); Marshak, M. L. [Univ. of Minnesota, Minneapolis, MN (United States); Mehdiyev, R. [Univ. of Texas, Austin, TX (United States); Meier, J. [Univ. of Minnesota, Minneapolis, MN (United States); Miller, W. [Univ. of Minnesota, Minneapolis, MN (United States); Naples, D. [Univ. of Pittsburgh, PA (United States); Nelson, J. K. [College of William and Mary, Williamsburg, VA (United States); Nichol, R. J. [Univ. College London, London (United Kingdom); Patterson, R. B. [California Inst. of Technology (CalTech), Pasadena, CA (United States); Paolone, V. [Univ. of Pittsburgh, PA (United States); Pawloski, G. [Univ. of Minnesota, Minneapolis, MN (United States); Perch, A. [Univ. College London, London (United Kingdom); Pfutzner, M. [Univ. College London, London (United Kingdom); Proga, M. [Univ. of Texas, Austin, TX (United States); Qian, X. [Brookhaven National Lab. (BNL), Upton, NY (United States); Radovic, A. [Univ. College London, London (United Kingdom); Sanchez, M. C. [Iowa State Univ., Ames, IA (United States); Schreiner, S. [Univ. of Minnesota, Minneapolis, MN (United States); Soldner-Rembold, S. [Univ. of Manchester (United Kingdom); Sousa, A. [Univ. of Cincinnati, OH (United States); Thomas, J. [Univ. College London, London (United Kingdom); Vahle, P. [College of William and Mary, Williamsburg, VA (United States); Wendt, C. [Univ. of Wisconsin, Madison, WI (United States); Whitehead, L. H. [Univ. College London, London (United Kingdom); Wojcicki, S. [Stanford Univ., CA (United States)

    2013-12-30

    This Letter of Intent outlines a proposal to build a large, yet cost-effective, 100 kton fiducial mass water Cherenkov detector that will initially run in the NuMI beam line. The CHIPS detector (CHerenkov detector In Mine PitS) will be deployed in a flooded mine pit, removing the necessity and expense of a substantial external structure capable of supporting a large detector mass. There are a number of mine pits in northern Minnesota along the NuMI beam that could be used to deploy such a detector. In particular, the Wentworth Pit 2W is at the ideal off-axis angle to contribute to the measurement of the CP violating phase. The detector is designed so that it can be moved to a mine pit in the LBNE beam line once that becomes operational.

  20. Measuring the Attenuation Length of Water in the CHIPS-M Water Cherenkov Detector

    CERN Document Server

    Amat, F; Bryant, J; Carroll, T J; Germani, S; Joyce, T; Kreisten, B; Marshak, M; Meier, J; Nelson, J; Perch, A; Pfuzner, M; De Rijck, S; Salazar, R; Thomas, J; Trokan-Tenorio, J; Vahle, P; Wade, R; Whitehead, L; Whitney, M

    2016-01-01

    The water at the proposed site of the CHIPS water Cherenkov detector has been studied to measure its attenuation length for Cherenkov light as a function of filtering time. A scaled model of the CHIPS detector filled with water from the Wentworth 2W pit, proposed site of the CHIPS deployment, in conjunction with a 3.2\\unit{m} vertical column filled with this water, was used to study the transmission of 405nm laser light. Results consistent with attenuation lengths of up to 100m were observed for this wavelength with filtration and UV sterilization alone.

  1. Measuring the attenuation length of water in the CHIPS-M water Cherenkov detector

    Science.gov (United States)

    Amat, F.; Bizouard, P.; Bryant, J.; Carroll, T. J.; Rijck, S. De; Germani, S.; Joyce, T.; Kriesten, B.; Marshak, M.; Meier, J.; Nelson, J. K.; Perch, A. J.; Pfützner, M. M.; Salazar, R.; Thomas, J.; Trokan-Tenorio, J.; Vahle, P.; Wade, R.; Wendt, C.; Whitehead, L. H.; Whitney, M.

    2017-02-01

    The water at the proposed site of the CHIPS water Cherenkov detector has been studied to measure its attenuation length for Cherenkov light as a function of filtering time. A scaled model of the CHIPS detector filled with water from the Wentworth 2W pit, proposed site of the CHIPS deployment, in conjunction with a 3.2 m vertical column filled with this water, was used to study the transmission of 405 nm laser light. Results consistent with attenuation lengths of up to 100 m were observed for this wavelength with filtration and UV sterilization alone.

  2. The performance of a prototype array of water Cherenkov detectors for the LHAASO project

    Energy Technology Data Exchange (ETDEWEB)

    An, Q. [University of Science and Technology of China, Hefei 230026 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Bai, Y.X.; Bi, X.J.; Cao, Z. [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Chang, J.F. [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Chen, G.; Chen, M.J. [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Chen, S.M. [Tsinghua University, Beijing 100084 (China); Chen, S.Z. [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Chen, T.L. [University of Tibet, Lhasa 851600 (China); Chen, X. [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Chen, Y.T. [University of Yunnan, Kunming 650091 (China); Cui, S.W. [Normal University of Hebei, Shijiazhuang 050016 (China); Dai, B.Z. [University of Yunnan, Kunming 650091 (China); Du, Q. [Tsinghua University, Beijing 100084 (China); Danzengluobu [University of Tibet, Lhasa 851600 (China); Feng, C.F. [University of Shandong, Jinan 250100 (China); Feng, S.H.; Gao, B. [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Gao, S.Q. [National Space Science Center, Chinese Academy of Sciences, Beijing 100190 (China); and others

    2013-10-01

    A large high-altitude air-shower observatory (LHAASO) is to be built at Shangri-La, Yunnan Province, China. This observatory is intended to conduct sub-TeV gamma astronomy, and as an important component of the LHAASO project, a water Cherenkov detector array (WCDA) is proposed. To investigate engineering issues and fully understand the water Cherenkov technique for detecting air showers, a prototype array at 1% scale of the LHAASO-WCDA has been built at Yang-Ba-Jing, Tibet, China. This paper introduces the prototype array setup and studies its performance by counting rate of each photomultiplier tube (PMT), trigger rates at different PMT multiplicities, and responses to air showers. Finally, the reconstructed shower directions and angular resolutions of the detected showers for the prototype array are given. -- Highlights: • The technique of the water Cherenkov array is studied. • Engineering issues of the water Cherenkov array are investigated. • The PMTs and electronics of the water Cherenkov array are tested. • Some key parameters of the water Cherenkov array are measured.

  3. Data analysis for solar neutrinos observed by water Cherenkov detectors{sup *}

    Energy Technology Data Exchange (ETDEWEB)

    Koshio, Yusuke [Okayama University, Okayama (Japan)

    2016-04-15

    A method of analyzing solar neutrino measurements using water-based Cherenkov detectors is presented. The basic detection principle is that the Cherenkov photons produced by charged particles via neutrino interaction are observed by photomultiplier tubes. A large amount of light or heavy water is used as a medium. The first detector to successfully measure solar neutrinos was Kamiokande in the 1980's. The next-generation detectors, i.e., Super-Kamiokande and the Sudbury Neutrino Observatory (SNO), commenced operation from the mid-1990's. These detectors have been playing the critical role of solving the solar neutrino problem and determining the neutrino oscillation parameters over the last decades. The future prospects of solar neutrino analysis using this technique are also described. (orig.)

  4. R&D project for Gd-doped water Cherenkov detector

    Science.gov (United States)

    Mori, Takaaki; Super-Kamiokande Collaboration

    2013-02-01

    A dedicated test facility for a proposed Gadolinium doped water Cherenkov detector is being constructed in the Kamioka mine near the Super Kamiokande detector. Anti-electron neutrinos (bar ve) from inverse beta decay can be identified with high efficiency by taking advantage of Gd's large cross section on thermal neutron capture and by taking coincidence of a prompt positron and the delayed 8 MeV gamma cascades.

  5. Towards a network of atmospheric Cherenkov detectors 7

    Energy Technology Data Exchange (ETDEWEB)

    Robin, M. [Ecole Polytechnique, 91 - Palaiseau (France); Weekes, T.C. [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA (United States); Mori, M. [Tokyo Univ., Institute for Cosmic Ray Research (Japan); Mariotti, M. [Padova Univ., INFN (Italy); Hofmann, W.; Aharonian, F. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Sinitsyna, V. [P.N. Lebedev Physical Institute, Moscow (Russian Federation); Smith, D. [Centre d' Etudes Nucleaires de Bordeaux Gradignan, 33 - Gradignan (France); Marleau, P. [California Univ., Davis, CA (United States); Sinnis, G. [Los Alamos National Lab., NM (United States); Volk, H. [Max-Planck-Institut fur Kernphysik (Germany); Jager, O. de [South Africa Univ., North-West (South Africa); Harding, A. [NASA Goddard Space Flight Center (United States); Coppi, P. [Yale Univ., New Haven, CT (United States); Dermer, C. [Naval Research Laboratory (United States); Goldwurm, A.; Paul, J. [CEA Saclay, Dept. d' Astrophysique, de Physique des Particules de Physique Nucleaire et de l' Instrumentation Associee, 91- Gif sur Yvette (France); Puhlhofer, G. [Landessternwarte Heidelberg (Germany); Bernardini, E. [DESy-Zeuthen (Germany); Swordy, S. [Chicago Univ., IL (United States); Yoshikoshi, T. [Tokyo Univ., Tanashi (Japan). Inst. for Cosmic Ray Research; Teshima, M. [Max-Planck-Institute for Physics, Munich (Germany); Punch, M. [Astrophysique et Cosmologie (APC), College de France, 75 - Paris (France)

    2005-07-01

    This document gathers the papers and transparencies presented at the conference. The main part of the conference was organized into 6 sessions: 1) the review of present experiments (Veritas, Cangaroo-3, Magic, Hess-1, Shalon, Cactus, Cygnus-X-3...), 2) calibration and analysis techniques in VHE (very high energy) astrophysics, 3) multi-wavelength observations and phenomenology of sources, 4) the future of ground-based VHE astronomy, 5) developments in instrumentation for Cherenkov telescopes, and 6) the evolution of the field and its link with mainstream astrophysics.

  6. Development of a 13-in. Hybrid Avalanche Photo-Detector (HAPD) for a next generation water Cherenkov detector

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, H. [Department of Physics, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan)]. E-mail: nakkan@hep.phys.s.u-tokyo.ac.jp; Kusaka, A. [Department of Physics, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Kakuno, H. [Department of Physics, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Abe, T. [Department of Physics, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Iwasaki, M. [Department of Physics, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Aihara, H. [Department of Physics, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Shiozawa, M. [Institute for Cosmic Ray Research, University of Tokyo, Higashi-Mozumi, Kamioka-cho, Hida city, Gifu 506-1205 (Japan); Tanaka, M. [Institute for Particle and Nuclear Studies, High Energy Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Kyushima, H. [Electron Tube Division, Hamamatsu Photonics K.K., 314-5 Simokanzo, Iwata City 438-0193, Shizuoka (Japan); Suyama, M. [Electron Tube Division, Hamamatsu Photonics K.K., 314-5 Simokanzo, Iwata City 438-0193, Shizuoka (Japan); Kawai, Y. [Electron Tube Division, Hamamatsu Photonics K.K., 314-5 Simokanzo, Iwata City 438-0193, Shizuoka (Japan)

    2006-11-01

    We have developed a 13-in. Hybrid Avalanche Photo-Detector (HAPD) for photosensors in next generation water Cherenkov type detectors. We study the performance of the HAPD and the results show good time resolution better than {sigma}=1ns, good sensitivity for single photon detection, wide dynamic range, and good uniformity on the photocathode. The HAPD is also expected to be less expensive than large PMTs because of its simpler structure without dynodes.

  7. Tagging Spallation Backgrounds with Showers in Water-Cherenkov Detectors

    CERN Document Server

    Li, Shirley Weishi

    2015-01-01

    Cosmic-ray muons and especially their secondaries break apart nuclei ("spallation") and produce fast neutrons and beta-decay isotopes, which are backgrounds for low-energy experiments. In Super-Kamiokande, these beta decays are the dominant background in 6--18 MeV, relevant for solar neutrinos and the diffuse supernova neutrino background. In a previous paper, we showed that these spallation isotopes are produced primarily in showers, instead of in isolation. This explains an empirical spatial correlation between a peak in the muon Cherenkov light profile and the spallation decay, which Super-Kamiokande used to develop a new spallation cut. However, the muon light profiles that Super-Kamiokande measured are grossly inconsistent with shower physics. We show how to resolve this discrepancy and how to reconstruct accurate profiles of muons and their showers from their Cherenkov light. We propose a new spallation cut based on these improved profiles and quantify its effects. Our results can significantly benefit ...

  8. Study of timing performance of Silicon Photomultiplier and application for a Cherenkov detector

    CERN Document Server

    Ahmed, G S M; Marton, J; Suzuki, K

    2010-01-01

    Silicon photomultipliers are very versatile photo detectors due to their high photon detection efficiency, fast response, single photon counting capability, high amplification, and their insensitivity to magnetic fields. At our institute we are studying the performance of these photo detectors at various operating conditions. On the basis of the experience in the laboratory we built a prototype of a timing Cherenkov detector consisting of a quartz radiator with two $3\\times 3$ mm$^2$ MPPCs S10362-33-100C from Hamamatsu Photonics as photodetectors. The MPPC sensors were operated with Peltier cooling to minimize thermal noise and to avoid gain drifts. The test measurements at the DA$\\Phi$NE Beam-Test Facility (BTF) at the Laboratori Nazionali di Frascati (LNF) with pulsed 490 MeV electrons and the results on timing performance with Cherenkov photons are presented.

  9. LUCID A Cherenkov Tube Based Detector for Monitoring the ATLAS Experiment Luminosity

    CERN Document Server

    Sbrizzi, A

    2007-01-01

    The LUCID (LUminosity Cherenkov Integrating Detector) apparatus is composed by two symmetric arms deployed at about 17 m from the ATLAS interaction point. The purpose of this detector, which will be installed in january 2008, is to monitor the luminosity delivered by the LHC machine to the ATLAS experiment. An absolute luminosity calibration is needed and it will be provided by a Roman Pot type detector with the two arms placed at about 240 m from the interaction point. Each arm of the LUCID detector is based on an aluminum vessel containing 20 Cherenkov tubes, 15 mm diameter and 1500 mm length, filled with C4F10 radiator gas at 1.5 bar. The Cherenkov light generated by charged particles above the threshold is collected by photomultiplier tubes (PMT) directly placed at the tubes end. The challenging aspect of this detector is its readout in an environment characterized by the high dose of radiation (about 0.7 Mrad/year at 10^33cm^2 s^-1) it must withstand. In order to fulfill these radiation hardness requirem...

  10. Gamma Ray Measurements at OMEGA with the Newest Gas Cherenkov Detector “GCD-3”

    Science.gov (United States)

    McEvoy, A. M.; Herrmann, H. W.; Kim, Y.; Zylstra, A. B.; Young, C. S.; Fatherley, V. E.; Lopez, F. E.; Oertel, J. A.; Sedillo, T. J.; Archuleta, T. N.; Aragonez, R. J.; Malone, R. M.; Horsfield, C. J.; Rubery, M.; Gales, S.; Leatherland, A.; Stoeffl, W.; Gatu Johnson, M.; Shmayda, W. T.; Batha, S. H.

    2016-05-01

    Initial results from the newest Gas Cherenkov Detector (GCD-3) are reported demonstrating improved performance over previous GCD iterations. Increased shielding and lengthening of the Cherenkov photon optical path have resulted in a diminished precursor signal with increased temporal separation between the precursor and the primary DT Cherenkov signal. Design changes resulted in a measured GCD-3 sensitivity comparable to GCD-1 at identical 100 psia CO2 operation. All metal gasket seals and pressure vessel certification to 400 psia operation allow for a GCD-3 lower Cherenkov threshold of 1.8 MeV using the fluorinated gas C2F6 as compared to the 6.3 MeV lower limit of GCD-1 and GCD-2. Calibration data will be used to benchmark GEANT4 and ACCEPT detector models. The GCD-3 acts as a prototype for the Super GCD being fielded at the National Ignition Facility (NIF) as part of the National Diagnostics Plan and will be installed at NIF in early 2016.

  11. Calibration of Cherenkov detectors for monoenergetic photon imaging in active interrogation applications

    Science.gov (United States)

    Rose, P. B.; Erickson, A. S.

    2015-11-01

    Active interrogation of cargo containers using monoenergetic photons offers a rapid and low-dose approach to search for shielded special nuclear materials. Cherenkov detectors can be used for imaging of the cargo provided that gamma ray energies used in interrogation are well resolved, as the case in 11B(d,n-γ)12C reaction resulting in 4.4 MeV and 15.1 MeV photons. While an array of Cherenkov threshold detectors reduces low energy background from scatter while providing the ability of high contrast transmission imaging, thus confirming the presence of high-Z materials, these detectors require a special approach to energy calibration due to the lack of resolution. In this paper, we discuss the utility of Cherenkov detectors for active interrogation with monoenergetic photons as well as the results of computational and experimental studies of their energy calibration. The results of the studies with sources emitting monoenergetic photons as well as complex gamma ray spectrum sources, for example 232Th, show that calibration is possible as long as the energies of photons of interest are distinct.

  12. Ring imaging Cherenkov detector of PHENIX experiment at RHIC

    CERN Document Server

    Akiba, Y; Burward-Hoy, J; Chappell, R; Crook, D; Ebisu, K; Emery, M S; Ferriera, J; Frawley, A D; Hamagaki, H; Hara, H; Hayano, R S; Hemmick, T K; Hibino, M; Hutter, R; Kennedy, M; Kikuchi, J; Matsumoto, T; Moscone, C G; Nagasaka, Y; Nishimura, S; Oyama, K; Sakaguchi, T; Salomone, S; Shigaki, K; Tanaka, Y; Walker, J W; Wintenberg, A L; Young, G R

    1999-01-01

    The RICH detector of the PHENIX experiment at RHIC is currently under construction. Its main function is to identity electron tracks in a very high particle density, about 1000 charged particles per unit rapidity, expected in the most violent collisions at RHIC. The design and construction status of the detector and its expected performance are described.

  13. The CLEO-III Ring Imaging Cherenkov Detector

    CERN Document Server

    Mountain, R J; Artuso, M; Ayad, R; Azfar, F; Coan, T E; Efimov, A; Fadeev, V; Kopp, S E; Kubota, Y; Lipeles, E; Majumder, G; Schuh, S; Skwarnicki, T; Smith, A; Staeck, J; Stone, S; Viehhauser, G; Volobuev, I P

    1999-01-01

    The CLEO-III Detector upgrade for charged particle identification is discussed. The RICH design uses solid LiF crystal radiators coupled with multi-wire chamber photon detectors, using TEA as the photosensor, and low-noise Viking readout electronics. Results from our beam test at Fermilab are presented.

  14. The aerogel threshold Cherenkov detector for the High Momentum Spectrometer in Hall C at Jefferson Lab

    CERN Document Server

    Asaturyan, R; Fenker, H; Gaskell, D; Huber, G M; Jones, M; Mack, D; Mkrtchyan, H G; Metzger, B; Novikoff, N; Tadevosyan, V; Vulcan, W; Wood, S

    2004-01-01

    We describe a new aerogel threshold Cherenkov detector installed in the HMS spectrometer in Hall C at Jefferson Lab. The Hall C experimental program in 2003 required an improved particle identification system for better identification of pi/K/P, which was achieved by installing an additional threshold Cherenkov counter. Two types of aerogel with n=1.03 and n=1.015 allow one to reach 10^{-3} proton and 10^{-2} kaon rejection in the 1-5 GeV/c momentum range with pion detection efficiency better than 99% (97%). The detector response shows no significant position dependence due to a diffuse light collection technique. The diffusion box was equipped with 16 Photonis XP4572 PMT's. The mean number of photoelectrons in saturation was ~16 and ~8, respectively. Moderate particle identification is feasible near threshold.

  15. Reconstructing the direction of reactor antineutrinos via electron scattering in Gd-doped water Cherenkov detectors

    Science.gov (United States)

    Hellfeld, D.; Bernstein, A.; Dazeley, S.; Marianno, C.

    2017-01-01

    The potential of elastic antineutrino-electron scattering in a Gd-doped water Cherenkov detector to determine the direction of a nuclear reactor antineutrino flux was investigated using the recently proposed WATCHMAN antineutrino experiment as a baseline model. The expected scattering rate was determined assuming a 13-km standoff from a 3.758-GWt light water nuclear reactor and the detector response was modeled using a Geant4-based simulation package. Background was estimated via independent simulations and by scaling published measurements from similar detectors. Background contributions were estimated for solar neutrinos, misidentified reactor-based inverse beta decay interactions, cosmogenic radionuclides, water-borne radon, and gamma rays from the photomultiplier tubes (PMTs), detector walls, and surrounding rock. We show that with the use of low background PMTs and sufficient fiducialization, water-borne radon and cosmogenic radionuclides pose the largest threats to sensitivity. Directional sensitivity was then analyzed as a function of radon contamination, detector depth, and detector size. The results provide a list of experimental conditions that, if satisfied in practice, would enable antineutrino directional reconstruction at 3σ significance in large Gd-doped water Cherenkov detectors with greater than 10-km standoff from a nuclear reactor.

  16. Reconstructing the direction of reactor antineutrinos via electron scattering in Gd-doped water Cherenkov detector

    Energy Technology Data Exchange (ETDEWEB)

    Hellfeld, D. [Texas A & M Univ., College Station, TX (United States); Dazeley, S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bernstein, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Marianno, C. [Texas A & M Univ., College Station, TX (United States)

    2015-11-25

    The potential of elastic antineutrino-electron scattering (ν¯e + e → ν¯e + e) in a Gd-doped water Cherenkov detector to determine the direction of a nuclear reactor antineutrino flux was investigated using the recently proposed WATCHMAN antineutrino experiment as a baseline model. The expected scattering rate was determined assuming a 13 km standoff from a 3.758 GWt light water nuclear reactor. Background was estimated via independent simulations and by appropriately scaling published measurements from similar detectors. Many potential backgrounds were considered, including solar neutrinos, misidentified reactor-based inverse beta decay interactions, cosmogenic radionuclide and water-borne radon decays, and gamma rays from the photomultiplier tubes, detector walls, and surrounding rock. The detector response was modeled using a GEANT4-based simulation package. The results indicate that with the use of low radioactivity PMTs and sufficient fiducialization, water-borne radon and cosmogenic radionuclides pose the largest threats to sensitivity. The directional sensitivity was then analyzed as a function of radon contamination, detector depth, and detector size. Lastly, the results provide a list of theoretical conditions that, if satisfied in practice, would enable nuclear reactor antineutrino directionality in a Gd-doped water Cherenkov detector approximately 10 km from a large power reactor.

  17. Study of wavelength-shifting chemicals for use in large-scale water Cherenkov detectors

    CERN Document Server

    Sweany, M; Dazeley, S; Dunmore, J; Felde, J; Svoboda, R; Tripathi, M

    2011-01-01

    Cherenkov detectors employ various methods to maximize light collection at the photomultiplier tubes (PMTs). These generally involve the use of highly reflective materials lining the interior of the detector, reflective materials around the PMTs, or wavelength-shifting sheets around the PMTs. Recently, the use of water-soluble wavelength-shifters has been explored to increase the measurable light yield of Cherenkov radiation in water. These wave-shifting chemicals are capable of absorbing light in the ultravoilet and re-emitting the light in a range detectable by PMTs. Using a 250 L water Cherenkov detector, we have characterized the increase in light yield from three compounds in water: 4-Methylumbelliferone, Carbostyril-124, and Amino-G Salt. We report the gain in PMT response at a concentration of 1 ppm as: 1.88 $\\pm$ 0.02 for 4-Methylumbelliferone, stable to within 0.5% over 50 days, 1.37 $\\pm$ 0.03 for Carbostyril-124, and 1.20 $\\pm$ 0.02 for Amino-G Salt. The response of 4-Methylumbelliferone was modele...

  18. An Intermediate Water Cherenkov Detector at J-PARC

    CERN Document Server

    ,

    2016-01-01

    Recent neutrino oscillation results have shown that the existing long baseline experiments have some sensitivity to the effects of CP violation in the neutrino sector. This sensitivity is currently statistically limited, but the next generation of experiments, DUNE and Hyper-K, will provide an order of magnitude more events. To reach the full potential of these datasets we must achieve a commensurate improvement in our understanding of the systematic uncertainties that beset them. This talk describes two proposed intermediate detectors for the current and future long baseline oscillation experiments in Japan, TITUS and NuPRISM. These detectors are discussed in the context of the current T2K oscillation analysis, highlighting the ways in which they could reduce the systematic uncertainty on this measurement. The talk also describes the short baseline oscillation sensitivity of NuPRISM along with the neutrino scattering measurements the detector makes possible.

  19. Large acceptance forward Cherenkov detector for the BRAHMS experiment at RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Budick, B., E-mail: bb2@nyu.ed [New York University, New York, NY 10003 (United States); Beavis, D., E-mail: beavis@bnl.go [Brookhaven National Laboratory, Upton, NY 11973 (United States); Chasman, C., E-mail: chasman@bnl.go [Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2010-09-21

    A multi-element detector based on Cherenkov radiation in plastic and on photomultiplier tubes has been constructed that is particularly useful in collider experiments. The detector covers the pseudorapidity interval 3.23<{eta}<5.25 with large acceptance for the products of proton-proton and heavy ion collisions. The detector's primary purposes are determining the vertex of the interaction, providing a minimum bias trigger, finding the start time for time of flight (and other timing applications), and monitoring the luminosity. Monte Carlo simulations describe the pulse height response of the detector well, as does an analytic expression that has been developed. The detector performed well in the RHIC experiment BRAHMS.

  20. Geant4 based simulation of the Water Cherenkov Detectors of the LAGO Project

    CERN Document Server

    Calderón, R; Núñez, L A

    2015-01-01

    To characterize the signals registered by the different types of water Cherenkov detectors (WCD) used by the Latin American Giant Observatory (LAGO) Project, it is necessary to develop detailed simulations of the detector response to the flux of secondary particles at the detector level. These particles are originated during the interaction of cosmic rays with the atmosphere. In this context, the LAGO project aims to study the high energy component of gamma rays bursts (GRBs) and space weather phenomena by looking for the solar modulation of galactic cosmic rays (GCRs). Focus in this, a complete and complex chain of simulations is being developed that account for geomagnetic effects, atmospheric reaction and detector response at each LAGO site. In this work we shown the first steps of a GEANT4 based simulation for the LAGO WCD, with emphasis on the induced effects of the detector internal diffusive coating.

  1. Trends in the development of large area photon detectors for Cherenkov light imaging applications

    CERN Document Server

    Nappi, E

    2003-01-01

    Since the successful operations of hi-tech devices at OMEGA, DELPHI and SLD, the technique of Cherenkov light imaging has gone through an impressive and fruitful evolution driven by the conception of novel large area photon detectors. The well-assessed potentialities of thin CsI films, employed as reflective photoconverters in gas counters operated at atmospheric pressure, will be compared with the promising features of hybrid and multianode vacuum photomultipliers. Recently proposed single-photon gaseous detectors based on GEMs will also be reviewed.

  2. A quartz Cherenkov detector for Compton-polarimetry at future e{sup +}e{sup -} colliders

    Energy Technology Data Exchange (ETDEWEB)

    List, Jenny [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Vauth, Annika; Vormwald, Benedikt [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Hamburg Univ. (Germany). Inst. fuer Experimentalphysik

    2015-02-15

    Precision polarimetry is essential for future e{sup +}e{sup -} colliders and requires Compton polarimeters designed for negligible statistical uncertainties. In this paper, we discuss the design and construction of a quartz Cherenkov detector for such Compton polarimeters. The detector concept has been developed with regard to the main systematic uncertainties of the polarisation measurements, namely the linearity of the detector response and detector alignment. Simulation studies presented here imply that the light yield reachable by using quartz as Cherenkov medium allows to resolve in the Cherenkov photon spectra individual peaks corresponding to different numbers of Compton electrons. The benefits of the application of a detector with such single-peak resolution to the polarisation measurement are shown for the example of the upstream polarimeters foreseen at the International Linear Collider. Results of a first testbeam campaign with a four-channel prototype confirming simulation predictions for single electrons are presented.

  3. Design and fabrication of a window for the gas Cherenkov detector 3

    Science.gov (United States)

    Fatherley, V. E.; Bingham, D. A.; Cartelli, M. D.; DiDomizio, R. A.; Griego, J. R.; Herrmann, H. W.; Lopez, F. E.; Oertel, J. A.; Pollack, M. J.

    2016-11-01

    The gas Cherenkov detector 3 was designed at Los Alamos National Laboratory for use in inertial confinement fusion experiments at both the Omega Laser Facility and the National Ignition Facility. This instrument uses a low-Z gamma-to-electron convertor plate and high pressure gas to convert MeV gammas into UV/visible Cherenkov photons for fast optical detection. This is a follow-on diagnostic from previous versions, with two notable differences: the pressure of the gas is four times higher, and it allows the use of fluorinated gas, requiring metal seals. These changes force significant changes in the window component, having a unique set of requirements and footprint limitations. The selected solution for this component, a sapphire window brazed into a stainless steel flange housing, is described.

  4. Performance of the Two Aerogel Cherenkov Detectors of the JLab Hall A Hadron Spectrometer

    CERN Document Server

    Marrone, S; Acha, A; Cisbani, E; Coman, M; Cusanno, F; De Jager, C W; De Leo, R; Gao, H; Garibaldi, F; Higinbotham, D W; Iodice, M; LeRose, J J; Macchia, D; Markowitz, P; Nappia, E; Palmisano, F; Urciuoli, G M; van der Werf, I; Xiang, H; Zhu, L Y

    2008-01-01

    We report on the design and commissioning of two silica aerogel Cherenkov detectors with different refractive indices. In particular, extraordinary performance in terms of the number of detected photoelectrons was achieved through an appropriate choice of PMT type and reflector, along with some design considerations. After four years of operation, the number of detected photoelectrons was found to be noticeably reduced in both detectors as a result of contamination, yellowing, of the aerogel material. Along with the details of the set-up, we illustrate the characteristics of the detectors during different time periods and the probable causes of the contamination. In particular we show that the replacement of the contaminated aerogel and parts of the reflecting material has almost restored the initial performance of the detectors.

  5. Probing supernova shock waves and neutrino flavor transitions in next-generation water-Cherenkov detectors

    CERN Document Server

    Fogli, G L; Mirizzi, A; Montanino, D

    2004-01-01

    Several current projects aim at building a large water-Cherenkov detector, with a fiducial volume about 20 times larger than in the current Super-Kamiokande experiment. These projects include the Underground nucleon decay and Neutrino Observatory (UNO) in the Henderson Mine (Colorado), the Hyper-Kamiokande (HK) detector in the Tochibora Mine (Japan), and the MEgaton class PHYSics (MEMPHYS) detector in the Frejus site (Europe). We study the physics potential of a reference next-generation detector (0.4 Mton of fiducial mass) in providing information on supernova neutrino flavor transitions with unprecedented statistics. After discussing the ingredients of our calculations, we compute neutrino event rates from inverse beta decay ($\\bar\

  6. Aerogel Cherenkov detector for characterizing the intense flash x-ray source, Cygnus, spectrum

    Science.gov (United States)

    Kim, Y.; Herrmann, H. W.; McEvoy, A. M.; Young, C. S.; Hamilton, C.; Schwellenbach, D. D.; Malone, R. M.; Kaufman, M. I.; Smith, A. S.

    2016-11-01

    An aerogel Cherenkov detector is proposed to measure the X-ray energy spectrum from the Cygnus—intense flash X-ray source operated at the Nevada National Security Site. An array of aerogels set at a variety of thresholds between 1 and 3 MeV will be adequate to map out the bremsstrahlung X-ray production of the Cygnus, where the maximum energy of the spectrum is normally around 2.5 MeV. In addition to the Cherenkov radiation from aerogels, one possible competing light-production mechanism is optical transition radiation (OTR), which may be significant in aerogels due to the large number of transitions from SiO2 clusters to vacuum voids. To examine whether OTR is a problem, four aerogel samples were tested using a mono-energetic electron beam (varied in the range of 1-3 MeV) at NSTec Los Alamos Operations. It was demonstrated that aerogels can be used as a Cherenkov medium, where the rate of the light production is about two orders magnitude higher when the electron beam energy is above threshold.

  7. Mass Composition Sensitivity of an Array of Water Cherenkov and Scintillation Detectors

    CERN Document Server

    Gonzalez, Javier G; Roth, Markus

    2011-01-01

    We consider a hybrid array composed of scintillation and water Cherenkov detectors designed to measure the cosmic ray primary mass composition at energies of about 1 EeV. We have developed a simulation and reconstruction chain to study the theoretical performance of such an array. In this work we investigate the sensitivity of mass composition observables in relation to the geometry of the array. The detectors are arranged in a triangular grid with fixed 750 m spacing and the configuration of the scintillator detectors is optimized for mass composition sensitivity. We show that the performance for composition determination can be compared favorably to that of Xmax measurements after the difference in duty cycles is considered.

  8. TORCH - Cherenkov and Time-of-Flight PID Detector for the LHCb Upgrade at CERN

    Science.gov (United States)

    Föhl, K.; Brook, N.; Castillo García, L.; Conneely, T.; Cussans, D.; Forty, R.; Frei, C.; Gao, R.; Gys, T.; Harnew, N.; Milnes, J.; Piedigrossi, D.; Rademacker, J.; Ros Garcì a, A.; van Dijk, M.

    2016-05-01

    TORCH is a large-area precision time-of-flight detector, based on Cherenkov light production and propagation in a quartz radiator plate, which is read out at its edges. TORCH is proposed for the LHCb experiment at CERN to provide positive particle identification for kaons, and is currently in the Research-and-Development phase. A brief overview of the micro-channel plate photon sensor development, the custom-made electronics, and an introduction to the current test beam activities is given. Optical readout solutions are presented for the potential use of BaBar DIRC bar boxes as part of the TORCH configuration in LHCb.

  9. Study of solar activity by measuring cosmic rays with a water Cherenkov detector

    Energy Technology Data Exchange (ETDEWEB)

    Bahena Bias, Angelica [Facultad de ciencias FIsico-Matematicas, Universidad Michoacana de San Nicolas de Hidalgo, Avenida Francisco J. Mujica S/N Ciudad Universitaria C.P. 58030 Morelia, Michoacan (Mexico); Villasenor, Luis, E-mail: anbahena@ifm.umich.mx, E-mail: villasen@ifm.umich.mx [Instituto de Fisica y Matematicas, Universidad Michoacana de San Nicolas de Hidalgo, Avenida Francisco J. Mujica S/N Ciudad Universitaria C.P. 58030 Morelia, Michoacan (Mexico)

    2011-04-01

    We report on an indirect study of solar activity by using the Forbush effect which consists on the anti-correlation between the intensity of solar activity and the intensity of secondary cosmic radiation detected at ground level at the Earth. We have used a cylindrical water Cherenkov detector to measure the rate of arrival of secondary cosmic rays in Morelia Mich., Mexico, at 1950 m.a.s.l. We describe the analysis required to unfold the effect of atmospheric pressure and the search for Forbush decreases in our data, the latter correspond to more than one year of continuous data collection.

  10. Solar panels as air Cherenkov detectors for extremely high energy cosmic rays

    CERN Document Server

    Cecchini, S; Esposti, L D; Giacomelli, G; Guerra, M; Lax, I; Mandrioli, G; Parretta, A; Sarno, A; Schioppo, R; Sorel, M; Spurio, M

    2000-01-01

    Increasing interest towards the observation of the highest energy cosmic rayshas motivated the development of new detection techniques. The properties ofthe Cherenkov photon pulse emitted in the atmosphere by these very rareparticles indicate low-cost semiconductor detectors as good candidates fortheir optical read-out. The aim of this paper is to evaluate the viability of solar panels for thispurpose. The experimental framework resulting from measurements performed withsuitably-designed solar cells and large conventional photovoltaic areas ispresented. A discussion on the obtained and achievable sensitivities follows.

  11. Experimental study of the atmospheric neutrino backgrounds for proton decay to positron and neutral pion searches in water Cherenkov detectors

    CERN Document Server

    Mine, S; Andringa, S; Aoki, S; Argyriades, J; Asakura, K; Ashie, R; Berghaus, F; Berns, H; Bhang, H; Blondel, A; Borghi, S; Bouchez, J; Burguet-Castell, J; Casper, D; Catala, J; Cavata, C; Cervera-Villanueva, Anselmo; Chen, S M; Cho, K O; Choi, J H; Dore, U; Espinal, X; Fechner, M; Fernández, E; Fujii, Y; Fukuda, Y; Gomez-Cadenas, J; Gran, R; Hara, T; Hasegawa, M; Hasegawa, T; Hayato, Y; Helmer, R L; Hiraide, K; Hosaka, J; Ichikawa, A K; Iinuma, M; Ikeda, A; Ishida, T; Ishihara, K; Ishii, T; Ishitsuka, M; Itow, Y; Iwashita, T; Jang, H I; Jeon, E J; Jeong, I S; Joo, K K; Jover, G; Jung, C K; Kajita, T; Kameda, J; Kaneyuki, K; Kato, I; Kearns, E; Kim, C O; Khabibullin, M; Khotjantsev, A; Kielczewska, D; Kim, J Y; Kim, S B; Kitching, P; Kobayashi, K; Kobayashi, T; Konaka, A; Koshio, Y; Kropp, W; Kudenko, Yu; Kuno, Y; Kurimoto, Y; Kutter, T; Learned, J; Likhoded, S; Lim, I T; Loverre, P F; Ludovici, L; Maesaka, H; Mallet, J; Mariani, C; Matsuno, S; Matveev, V; McConnel, K; McGrew, C; Mikheyev, S; Minamino, A; Mineev, O; Mitsuda, C; Miura, M; Moriguchi, Y; Moriyama, S; Nakadaira, T; Nakahata, M; Nakamura, K; Nakano, I; Nakaya, T; Nakayama, S; Namba, T; Nambu, R; Nawang, S; Nishikawa, K; Nitta, K; Nova, F; Novella, P; Obayashi, Y; Okada, A; Okumura, K; Oser, S M; Oyama, Y; Pac, M Y; Pierre, F; Rodríguez, A; Saji, C; Sakuda, M; Sánchez, F; Scholberg, K; Schroeter, R; Sekiguchi, M; Shiozawa, M; Shiraishi, K; Sitjes, G; Smy, M; Sobel, H; Sorel, M; Stone, J; Sulak, L; Suzuki, A; Suzuki, Y; Tada, M; Takahashi, T; Takenaga, Y; Takeuchi, Y; Taki, K; Takubo, Y; Tamura, N; Tanaka, M; Terri, R; T'Jampens, S; Tornero-Lopez, A; Totsuka, Y; Vagins, M; Whitehead, L; Walter, C W; Wang, W; Wilkes, R J; Yamada, S; Yamada, Y; Yamamoto, S; Yanagisawa, C; Yershov, N; Yokoyama, H; Yokoyama, M; Yoo, J; Yoshida, M; Zalipska, J

    2008-01-01

    The atmospheric neutrino background for proton decay to positron and neutral pion in ring imaging water Cherenkov detectors is studied with an artificial accelerator neutrino beam for the first time. In total, about 314,000 neutrino events corresponding to about 10 megaton-years of atmospheric neutrino interactions were collected by a 1,000 ton water Cherenkov detector (KT). The KT charged-current single neutral pion production data are well reproduced by simulation programs of neutrino and secondary hadronic interactions used in the Super-Kamiokande (SK) proton decay search. The obtained proton to positron and neutral pion background rate by the KT data for SK from the atmospheric neutrinos whose energies are below 3 GeV is about two per megaton-year. This result is also relevant to possible future, megaton-scale water Cherenkov detectors.

  12. Selective Filtration of Gadolinium Trichloride for Use in Neutron Detection in Large Water Cherenkov Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Vagins, Mark R.

    2013-04-10

    Water Cherenkov detectors have been used for many years as inexpensive, effective detectors for neutrino interactions and nucleon decay searches. While many important measurements have been made with these detectors a major drawback has been their inability to detect the absorption of thermal neutrons. We believe an inexpensive, effective technique could be developed to overcome this situation via the addition to water of a solute with a large neutron cross section and energetic gamma daughters which would make neutrons detectable. Gadolinium seems an excellent candidate especially since in recent years it has become very inexpensive, now less than $8 per kilogram in the form of commercially-available gadolinium trichloride, GdCl{sub 3}. This non-toxic, non-reactive substance is highly soluble in water. Neutron capture on gadolinium yields a gamma cascade which would be easily seen in detectors like Super-Kamiokande. We have been investigating the use of GdCl{sub 3} as a possible upgrade for the Super-Kamiokande detector with a view toward improving its performance as a detector for atmospheric neutrinos, supernova neutrinos, wrong-sign solar neutrinos, reactor neutrinos, proton decay, and also as a target for the coming T2K long-baseline neutrino experiment. This focused study of selective water filtration and GdCl{sub 3} extraction techniques, conducted at UC Irvine, followed up on highly promising benchtop-scale and kiloton-scale work previously carried out with the assistance of 2003 and 2005 Advanced Detector Research Program grants.

  13. Tests of innovative photon detectors and integrated electronics for the large-area CLAS12 ring-imaging Cherenkov detector

    Energy Technology Data Exchange (ETDEWEB)

    Contalbrigo, Marco [INFN, Ferrara, Italy

    2015-07-01

    A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab. Its aim is to study the 3D nucleon structure in the yet poorly explored valence region by deep-inelastic scattering, and to perform precision measurements in hadron spectroscopy. The adopted solution foresees a novel hybrid optics design based on an aerogel radiator, composite mirrors and a densely packed and highly segmented photon detector. Cherenkov light will either be imaged directly (forward tracks) or after two mirror reflections (large angle tracks). Extensive tests have been performed on Hamamatsu H8500 and novel flat multi-anode photomultipliers under development and on various types of silicon photomultipliers. A large scale prototype based on 28 H8500 MA-PMTs has been realized and tested with few GeV/c hadron beams at the T9 test-beam facility of CERN. In addition a small prototype was used to study the response of customized SiPM matrices within a temperature interval ranging from 25 down to –25 °C. The preliminary results of the individual photon detector tests and of the prototype performance at the test-beams are here reported.

  14. Tests of innovative photon detectors and integrated electronics for the large-area CLAS12 ring-imaging Cherenkov detector

    Energy Technology Data Exchange (ETDEWEB)

    Contalbrigo, M., E-mail: contalbrigo@fe.infn.it

    2015-07-01

    A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab. Its aim is to study the 3D nucleon structure in the yet poorly explored valence region by deep-inelastic scattering, and to perform precision measurements in hadron spectroscopy. The adopted solution foresees a novel hybrid optics design based on an aerogel radiator, composite mirrors and a densely packed and highly segmented photon detector. Cherenkov light will either be imaged directly (forward tracks) or after two mirror reflections (large angle tracks). Extensive tests have been performed on Hamamatsu H8500 and novel flat multi-anode photomultipliers under development and on various types of silicon photomultipliers. A large scale prototype based on 28 H8500 MA-PMTs has been realized and tested with few GeV/c hadron beams at the T9 test-beam facility of CERN. In addition a small prototype was used to study the response of customized SiPM matrices within a temperature interval ranging from 25 down to −25 °C. The preliminary results of the individual photon detector tests and of the prototype performance at the test-beams are here reported.

  15. Layered water Cherenkov detector for the study of ultra high energy cosmic rays

    CERN Document Server

    Letessier-Selvon, Antoine; Blanco, Miguel; Maris, Ioana C; Settimo, Mariangela

    2014-01-01

    We present a new design for the water Cherenkov detectors that are in use in various cosmic ray observatories. This novel design can provide a significant improvement in the independent measurement of the muonic and electromagnetic component of extensive air showers. From such multi-component data an event by event classification of the primary cosmic ray mass becomes possible. According to popular hadronic interaction models, such as EPOS-LHC or QGSJetII-04, the discriminating power between iron and hydrogen primaries reaches Fisher values of $\\sim$ 2 or above for energies in excess of $10^{19}$ eV with a detector array layout similar to that of the Pierre Auger Observatory.

  16. Proposal for the geometrical distribution of the air cherenkov detectors for CHARM

    Science.gov (United States)

    Morales Reyes, A. R.; Martínez Bravo, O. M.

    2011-04-01

    In this work we propose the geometrical distribution of the air Cherenkov detectors array (ACD), who will be part of the Cosmic High Altitude Radiation Monitor Observatory (CHARM) located at Pico de Orizaba Volcano at 4300 m.a.s.l.. The proposal is based on a library of events built with photons, protons and iron nuclei as primary particles by montecarlo simulations with energies from 1014 eV to 1017 eV. The goal of this detectors will be to determinate the nature of primary cosmic radiation, through measuring the height at which the secondary particles generated reach his maximum number or Xmax, this quantity is related with the effective cross section and finally with the atomic number A of the primary particles. In addition to this we proposed an energy estimator based on the study of the lateral distribution function of the generated events.

  17. Proposal for the geometrical distribution of the air Cherenkov detectors for CHARM

    Energy Technology Data Exchange (ETDEWEB)

    Reyes Morales A R; Bravo Martinez O M, E-mail: hkanzaki@hotmail.com, E-mail: omartin@fcfm.buap.mx [Facultad de Ciencias Fisico Matematicas, Benemerita Universidad Autonoma de Puebla (Mexico)

    2011-04-01

    In this work we propose the geometrical distribution of the air Cherenkov detectors array (ACD), who will be part of the Cosmic High Altitude Radiation Monitor Observatory (CHARM) located at Pico de Orizaba Volcano at 4300 m.a.s.l.. The proposal is based on a library of events built with photons, protons and iron nuclei as primary particles by Monte Carlo simulations with energies from 10{sup 14} eV to 10{sup 17} eV. The goal of this detectors will be to determinate the nature of primary cosmic radiation, through measuring the height at which the secondary particles generated reach his maximum number or X{sub max}, this quantity is related with the effective cross section and finally with the atomic number A of the primary particles. In addition to this we proposed an energy estimator based on the study of the lateral distribution function of the generated events.

  18. Operating Water Cherenkov Detectors in high altitude sites for the Large Aperture GRB Observatory

    CERN Document Server

    Allard, D; Asorey, H; Barros, H; Bertou, X; Castillo, M; Chirinos, J M; De Castro, A; Flores, S; González, J; Berisso, M Gomez; Grajales, J; Guada, C; Day, W R Guevara; Ishitsuka, J; López, J A; Martínez, O; Melfo, A; Meza, E; Loza, P Miranda; Barbosa, E Moreno; Murrugarra, C; Núñez, L A; Ormachea, L J Otiniano; Pérez, G; Perez, Y; Ponce, E; Quispe, J; Quintero, C; Rivera, H; Rosales, M; Rovero, A C; Saavedra, O; Salazar, H; Tello, J C; Peralda, R Ticona; Varela, E; Velarde, A; Villaseñor, L; Wahl, D; Zamalloa, M A

    2009-01-01

    Water Cherenkov Detectors (WCD) are efficient detectors for detecting GRBs in the 10 GeV - 1 TeV energy range using the single particle technique, given their sensitivity to low energy secondary photons produced by high energy photons when cascading in the atmosphere. The Large Aperture GRB Observatory (LAGO) operates arrays of WCD in high altitude sites (above 4500 m a.s.l.) in Bolivia, Mexico and Venezuela, with planned extension to Peru. Details on the operation and stability of these WCD in remote sites with high background rates of particles will be detailed, and compared to simulations. Specific issues due to operation at high altitude, atmospheric effects and solar activity, as well as possible hardware enhancements will also be presented.

  19. Understanding fast neutrons utilizing a water Cherenkov detector and a gas-filled detector at the soudan underground laboratory

    Science.gov (United States)

    Ghimire, Chiranjibi

    Many experiments are currently searching for Weakly Interactive Massive Particles (WIMPs), a well-motivated class of hypothetical dark matter candidates. These direct dark matter detection experiments are located in deep underground to shield from cosmic-ray muons and the fast neutrons they produce. Fast neutrons are particularly dangerous to WIMP detectors because they can penetrate a WIMP-search experiment's neutron shielding. Once inside, these fast neutrons can interact with high-Z material near the WIMP detector, producing slower neutrons capable of mimicking the expected WIMP signal. My research uses two detectors located in Soudan Underground Laboratory to understand fast neutron production by muons in an underground environment: a water-Cherenkov detector sensitive to fast neutrons; and a gas-filled detector sensitive to charged particles like muons. The different kinds of selection criterion and their efficiencies are reported in this thesis. This thesis estimate the number of high energy neutron-like candidates associated with a nearby muon by using data from both detector systems.

  20. The water Cherenkov detector array for studies of cosmic rays at the University of Puebla

    Science.gov (United States)

    Cotzomi, J.; Moreno, E.; Murrieta, T.; Palma, B.; Pérez, E.; Salazar, H.; Villaseñor, L.

    2005-11-01

    We describe the design and performance of a hybrid extensive air shower detector array built on the Campus of the University of Puebla ( 19∘N, 90∘W, 800 g/cm2) to measure the energy, arrival direction and composition of primary cosmic rays with energies around 1 PeV, i.e., around the knee of the cosmic ray spectrum. The array consists of 3 water Cherenkov detectors of 1.86 m2 cross-section and 12 liquid scintillator detectors of 1 m2 distributed in a square grid with a detector spacing of 20 m over an area of 4000 m2. We discuss the calibration and stability of the array for both sets of detectors and report on preliminary measurements and reconstruction of the lateral distributions for the electromagnetic (EM) and muonic components of extensive air showers. We also discuss how the hybrid character of the array can be used to measure mass composition of the primary cosmic rays by estimating the relative contents of muons with respect to the EM component of extensive air showers. This facility is also used to train students interested in the field of cosmic rays.

  1. Prospects for CHIPS (R&D of Water Cherenkov Detectors in Mine Pits)

    CERN Document Server

    Lang, Karol

    2015-01-01

    CHIPS is an R&D program focused on designing and constructing a cost-effective large water Cherenkov detector (WCD) to study neutrino oscillations using accelerator beams. Traditional WCD's with a low energy threshold have been built in special large underground caverns. Civil construction of such facilities is costly and the excavation phase significantly delays the detector installation although, in the end, it offers a well-shielded apparatus with versatile physics program. Using concepts developed for the LBNE WCD (arXiv:1204.2295), we propose to submerge a detector in a deep water reservoir, which avoids the excavation and exploits the directionality of an accelerator neutrino beam for optimizing the detector. Following the LOI (arXiv:1307.5918), we have submerged a small test detector in a mine pit in Minnesota, 7 mrad off the NuMI axis. By adopting some technical ideas and solutions from IceCube and KM3NeT experiments, we are now focusing on designing a large (10 - 20 kt) isolated water container t...

  2. Note: Measurements of fast electrons in the TORE-SUPRA tokamak by means of modified Cherenkov-type diamond detector

    Energy Technology Data Exchange (ETDEWEB)

    Jakubowski, L.; Sadowski, M. J.; Zebrowski, J.; Rabinski, M.; Jakubowski, M. J.; Malinowski, K.; Mirowski, R. [National Centre for Nuclear Research (NCBJ), 7 Andrzeja Soltana Str., 05-400 Otwock (Poland); Lotte, Ph.; Goniche, M.; Gunn, J.; Colledani, G.; Pascal, J.-Y.; Basiuk, V. [CEA, IRFM, F-13108 Saint Paul-lez-Durance (France)

    2013-01-15

    The Note reports on experimental studies of ripple born fast electrons within the TORE-SUPRA facility, which were performed by means of a modified measuring head equipped with diamond detectors designed especially for recording the electron-induced Cherenkov radiation. There are presented signals produced by fast electrons in the TORE-SUPRA machine, which were recorded during two experimental campaigns performed in 2010. Shapes of these electron-induced signals are considerably different from those observed during the first measurements carried out by the prototype Cherenkov probe in 2008. An explanation of the observed differences is given.

  3. Extended performance gas Cherenkov detector for gamma-ray detection in high-energy density experiments

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, H. W., E-mail: herrmann@lanl.gov; Kim, Y. H.; Young, C. S.; Fatherley, V. E.; Lopez, F. E.; Oertel, J. A.; Batha, S. H. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Malone, R. M. [National Security Technologies, LLC, Los Alamos, New Mexico 87544 (United States); Rubery, M. S.; Horsfield, C. J. [Atomic Weapons Establishment, Aldermaston, Berkshire RG7 4PR (United Kingdom); Stoeffl, W. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Zylstra, A. B. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Shmayda, W. T. [Laboratory for Laser Energetics, Rochester, New York 14623 (United States)

    2014-11-15

    A new Gas Cherenkov Detector (GCD) with low-energy threshold and high sensitivity, currently known as Super GCD (or GCD-3 at OMEGA), is being developed for use at the OMEGA Laser Facility and the National Ignition Facility (NIF). Super GCD is designed to be pressurized to ≤400 psi (absolute) and uses all metal seals to allow the use of fluorinated gases inside the target chamber. This will allow the gamma energy threshold to be run as low at 1.8 MeV with 400 psi (absolute) of C{sub 2}F{sub 6}, opening up a new portion of the gamma ray spectrum. Super GCD operating at 20 cm from TCC will be ∼400 × more efficient at detecting DT fusion gammas at 16.7 MeV than the Gamma Reaction History diagnostic at NIF (GRH-6m) when operated at their minimum thresholds.

  4. Extended performance gas Cherenkov detector for gamma-ray detection in high-energy density experimentsa)

    Science.gov (United States)

    Herrmann, H. W.; Kim, Y. H.; Young, C. S.; Fatherley, V. E.; Lopez, F. E.; Oertel, J. A.; Malone, R. M.; Rubery, M. S.; Horsfield, C. J.; Stoeffl, W.; Zylstra, A. B.; Shmayda, W. T.; Batha, S. H.

    2014-11-01

    A new Gas Cherenkov Detector (GCD) with low-energy threshold and high sensitivity, currently known as Super GCD (or GCD-3 at OMEGA), is being developed for use at the OMEGA Laser Facility and the National Ignition Facility (NIF). Super GCD is designed to be pressurized to ≤400 psi (absolute) and uses all metal seals to allow the use of fluorinated gases inside the target chamber. This will allow the gamma energy threshold to be run as low at 1.8 MeV with 400 psi (absolute) of C2F6, opening up a new portion of the gamma ray spectrum. Super GCD operating at 20 cm from TCC will be ˜400 × more efficient at detecting DT fusion gammas at 16.7 MeV than the Gamma Reaction History diagnostic at NIF (GRH-6m) when operated at their minimum thresholds.

  5. Measurement of DT fusion and neutron-induced gamma-rays using gas Cherenkov Detector

    Science.gov (United States)

    Kim, Y.; Herrmann, H. W.; Evans, S.; Sedillo, T.; Langenbrunner, J. R.; Young, C. S.; Mack, J. M.; McEvoy, A.; Horsfield, C. J.; Rubery, M.; Ali, Z.; Stoeffl, W.

    2010-08-01

    A secondary gamma experiment was carried out using a Gas Cherenkov Detector (GCD) at the OMEGA laser facility. The primary experimental objective was to simulate neutron-induced secondary gamma production (n-γ) from a NIF implosion capsule, hohlraum, and thermo-mechanical package. The high-band width of the GCD enabled us to detect time delayed and Doppler broadened n-γ signals from five different puck materials (Si, SiO2, Al, Al2O3, Cu) placed near target chamber center. These measurements were used for MCNP & ITS ACCEPT code validation purposes. By a simple change of the GCD CO2 gas pressure the system can effectively eliminate signals induced by n-γ reactions and thereby allow quality measurements of DT fusion γ-rays that are produced at NIF (National Ignition Facility).

  6. Two-dimensional, single-photoelectron drift detector for Cherenkov ring imaging

    Energy Technology Data Exchange (ETDEWEB)

    Barrelet, E.; Seguinot, J.; Urban, M.; Ypsilantis, T. (Ecole Polytechnique, 91 - Palaiseau (France)); Ekeloef, T. (European Organization for Nuclear Research, Geneva (Switzerland)); Lund-Jensen, B. (Uppsala Univ. (Sweden)); Tocqueville, J. (College de France, 75 - Paris)

    1982-09-15

    A detector capable of imaging single photoelectrons has been constructed and tested. UV photons (>=5.4 eV) are converted to electrons with high quantum efficiency by photoionization of a small admixture (approx. equal to 1 Torr) of an organic vapour TMAE in a predominantly methane drift and amplifying gas at atmospheric pressure. The produced photoelectrons drift in a uniform applied electric field to a picket fence of proportional wires where each electron is amplified, counted and timed. The two-dimensional source point of each photoelectron is uniquely determined by the hit wire address and the arrival time. The detector has been tested by measuring ionization electrons produced in the drift gas be relativistic charged particles. The limiting precision to which the electron source point can be determined has been measured to be 300 ..mu..m (r.m.s.) in the drift direction and 370 ..mu..m in the wire plane direction. Additional independent error sources due to electron diffusion in the drift gas have been measured to be proportional to the square root of the drift distance with a proportionality constant of 235 ..mu..m/cmsup(1/2) in both directions. Drift velocities of electrons in various predominantly methane gas mixtures have been measured as a function of the applied electric field. The utilization of such a two-dimensional single electron drift detector for Cherenkov ring imaging is presented with a discussion of the advantages and limitations of the drift method for imaging.

  7. SiPM detectors for the ASTRI project in the framework of the Cherenkov Telescope Array

    Science.gov (United States)

    Billotta, Sergio; Marano, Davide; Bonanno, Giovanni; Belluso, Massimiliano; Grillo, Alessandro; Garozzo, Salvatore; Romeo, Giuseppe; Timpanaro, Maria Cristina; Maccarone, Maria Concetta C.; Catalano, Osvaldo; La Rosa, Giovanni; Sottile, Giuseppe; Impiombato, Domenico; Gargano, Carmelo; Giarrusso, Salavtore

    2014-07-01

    The Cherenkov Telescope Array (CTA) is a worldwide new generation project aimed at realizing an array of a hundred ground based gamma-ray telescopes. ASTRI (Astrofisica con Specchi a Tecnologia Replicante Italiana) is the Italian project whose primary target is the development of an end-to-end prototype, named ASTRI SST-2M, of the CTA small size class of telescopes devoted to investigation of the highest energy region, from 1 to 100 TeV. Next target is the implementation of an ASTRI/CTA mini-array based on seven identical telescopes. Silicon Photo-Multipliers (SiPMs) are the semiconductor photosensor devices designated to constitute the camera detection system at the focal plane of the ASTRI telescopes. SiPM photosensors are suitable for the detection of the Cherenkov flashes, since they are very fast and sensitive to the light in the 300-700nm wavelength spectrum. Their drawbacks compared to the traditional photomultiplier tubes are high dark count rates, after-pulsing and optical cross-talk contributions, and intrinsic gains strongly dependent on temperature. Nonetheless, for a single pixel, the dark count rate is well below the Night Sky Background, the effects of cross-talk and afterpulses are typically lower than 20%, and the gain can be kept stable against temperature variations by means of adequate bias voltage compensation strategies. This work presents and discusses some experimental results from a large set of measurements performed on the SiPM sensors to be used for the ASTRI SST-2M prototype camera and on recently developed detectors demonstrating outstanding performance for the future evolution of the project in the ASTRI/CTA mini-array.

  8. The Ring Imaging Cherenkov detector of the AMS experiment: test beam results with a prototype

    CERN Document Server

    Arruda, Luísa; Goncalves, Patrícia; Pereira, Rui

    2008-01-01

    The Alpha Magnetic Spectrometer (AMS) to be installed on the International Space Station (ISS) will be equipped with a proximity Ring Imaging Cherenkov (RICH) detector for measuring the velocity and electric charge of the charged cosmic particles. This detector will contribute to the high level of redundancy required for AMS as well as to the rejection of albedo particles. Charge separation up to iron and a velocity resolution of the order of 0.1% for singly charged particles are expected. A RICH protoptype consisting of a detection matrix with 96 photomultiplier units, a segment of a conical mirror and samples of the radiator materials was built and its performance was evaluated. Results from the last test beam performed with ion fragments resulting from the collision of a 158 GeV/c/nucleon primary beam of indium ions (CERN SPS) on a lead target are reported. The large amount of collected data allowed to test and characterize different aerogel samples and the sodium fluoride radiator. In addition, the reflec...

  9. ``Super'' Gas Cherenkov Detector for Gamma Ray Measurements at the National Ignition Facility

    Science.gov (United States)

    Herrmann, Hans W.; Kim, Y. H.; McEvoy, A. M.; Zylstra, A. B.; Lopez, F. E.; Griego, J. R.; Fatherley, V. E.; Oertel, J. A.; Batha, S. H.; Stoeffl, W.; Church, J. A.; Carpenter, A.; Rubery, M. S.; Horsfield, C. J.; Gales, S.; Leatherland, A.; Hilsabeck, T.; Kilkenny, J. D.; Malone, R. M.; Shmayda, W. T.

    2015-11-01

    New requirements to improve reaction history and ablator areal density measurements at the NIF necessitate improvements in sensitivity, temporal and spectral response relative to the existing Gamma Reaction History diagnostic (GRH-6m) located 6 meters from target chamber center (TCC). A new DIM-based ``Super'' Gas Cherenkov Detector (GCD) will ultimately provide ~ 200x more sensitivity to DT fusion gamma rays, reduce the effective temporal resolution from ~ 100 to ~ 10 ps and lower the energy threshold from 2.9 to 1.8 MeV, relative to GRH-6m. The first phase is to insert the existing coaxial GCD-3 detector into a reentrant well on the NIF chamber which will put it within 4 meters of TCC. This diagnostic platform will allow assessment of the x-ray radiation background environment within the well which will be fed into the shielding design for the follow-on ``Super'' GCD. It will also enable use of a pulse-dilation PMT which has the potential to improve the effective measurement bandwidth by ~ 10x relative to current PMT technology. GCD-3 has been thoroughly tested at the OMEGA Laser Facility and characterized at the High Intensity Gamma Ray Source (HIgS).

  10. Photon Detectors for the Ring Imaging Cherenkov Counters of the LHCb Experiment

    CERN Document Server

    Plackett, R W R

    2006-01-01

    This thesis reports on the author’s contribution to the development of the Ring Imaging Cherenkov(RICH) detectors in the LHCb experiment due to take data at the CERN Large Hadron Collider in 2007. The first chapter summarises the physics to be explored by the LHCb experiment; measurements of CP violating asymmetries and a study of rare B decay modes. A brief overview of other experiments studying B-physics is presented. The experiment itself is then described, focussing on the RICH system used for particle identification, with particular emphasis on the photondetectors. The thesis then reports on the work done by the author on the design of the RICH1 Magnetic Shield, that allows the photon detectors to operate in the fringe field of the LHCb dipole magnet, while fulfilling the conflicting requirement to provide additional magnetic bending power to aid the LHCb charged particle trigger. The design of all of the many sections of the shield are described in depth and the results of finite element simulations p...

  11. Attenuation study for Tibet Water Cherenkov Muon Detector Array-A

    CERN Document Server

    Gou, Quanbu; Liu, Cheng; Feng, Zhaoyang; Qian, Xiangli; Hou, Zhengtao

    2011-01-01

    The attenuation study of the long cable used in Tibet Water Cherenkov Muon Detector Array-A, called Tibet MD-A (one of 12 Tibet MD detectors), under the 37000 m2 Tibet air shower array, is reported. The cable frequency response is measured by using the sinusoidal signals, with which the influence of the cable on the pulse rise time is obtained. For the reason that the commercial 20 inch PMT (R3600_06) has a waterproof connection with the signal cable, one end of the signal cable is permanently connected to the PMT. Terminal reflection method is tested and used for measuring the signal attenuation. During the measurement, a practical way to eliminate the uncertainty caused by the baseline of the signal is achieved. To check the terminal reflection method, comparison measurement between it and QDC data taking method are carried out by using open-ended cables. The confirmed terminal reflection method is a fast and convenient method being suitable to online measure the signal attenuation for Tibet MD-A. The measu...

  12. Next generation gamma-ray Cherenkov detectors for the National Ignition Facility

    Science.gov (United States)

    Herrmann, H. W.; Kim, Y. H.; McEvoy, A. M.; Zylstra, A. B.; Young, C. S.; Lopez, F. E.; Griego, J. R.; Fatherley, V. E.; Oertel, J. A.; Stoeffl, W.; Khater, H.; Hernandez, J. E.; Carpenter, A.; Rubery, M. S.; Horsfield, C. J.; Gales, S.; Leatherland, A.; Hilsabeck, T.; Kilkenny, J. D.; Malone, R. M.; Hares, J. D.; Milnes, J.; Shmayda, W. T.; Stoeckl, C.; Batha, S. H.

    2016-11-01

    The newest generation of Gas Cherenkov Detector (GCD-3) employed in Inertial Confinement Fusion experiments at the Omega Laser Facility has provided improved performance over previous generations. Comparison of reaction histories measured using two different deuterium-tritium fusion products, namely gamma rays using GCD and neutrons using Neutron Temporal Diagnostic (NTD), have provided added credibility to both techniques. GCD-3 is now being brought to the National Ignition Facility (NIF) to supplement the existing Gamma Reaction History (GRH-6m) located 6 m from target chamber center (TCC). Initially it will be located in a reentrant well located 3.9 m from TCC. Data from GCD-3 will inform the design of a heavily-shielded "Super" GCD to be located as close as 20 cm from TCC. It will also provide a test-bed for faster optical detectors, potentially lowering the temporal resolution from the current ˜100 ps state-of-the-art photomultiplier tubes (PMT) to ˜10 ps Pulse Dilation PMT technology currently under development.

  13. CHERENCUBE: Concept definition and implementation challenges of a Cherenkov-based detector block for PET

    Energy Technology Data Exchange (ETDEWEB)

    Somlai-Schweiger, I., E-mail: ian.somlai@tum.de; Ziegler, S. I. [Nuklearmedizinische Klinik und Poliklinik, Klinikum rechts der Isar, Technische Universität München, Ismaninger Strasse 22, München 81675 (Germany)

    2015-04-15

    Purpose: A new concept for a depth-of-interaction (DOI) capable time-of-flight (TOF) PET detector is defined, based only on the detection of Cherenkov photons. The proposed “CHERENCUBE” consists of a cubic Cherenkov radiator with position-sensitive photodetectors covering each crystal face. By means of the spatial distribution of the detected photons and their time of arrival, the point of interaction of the gamma-ray in the crystal can be determined. This study analyzes through theoretical calculations and Monte Carlo simulations the potential advantages of the concept toward reaching a Cherenkov-only detector for TOF-PET with DOI capability. Furthermore, an algorithm for the DOI estimation is presented and the requirements for a practical implementation of the proposed concept are defined. Methods: The Monte Carlo simulations consisted of a cubic crystal with one photodetector coupled to each one of the faces of the cube. The sensitive area of the detector matched exactly the crystal size, which was varied in 1 mm steps between 1 × 1 × 1 mm{sup 3} and 10 × 10 × 10 mm{sup 3}. For each size, five independent simulations of ten thousand 511 keV gamma-rays were triggered at a fixed distance of 10 mm. The crystal chosen was PbWO{sub 4}. Its scintillation properties were simulated, but only Cherenkov photons were analyzed. Photodetectors were simulated having perfect photodetection efficiency and infinite time resolution. For every generated particle, the analysis considered its creation process, parent and daughter particles, energy, origin coordinates, trajectory, and time and position of detection. The DOI determination is based on the distribution of the emission time of all photons per event. These values are calculated as a function of the coordinates of detection and origin for every photon. The common origin is estimated by finding the distribution with the most similar emission time-points. Results: Detection efficiency increases with crystal size from

  14. An attempt to identify the muonic and electromagnetic components of extensive showers in water Cherenkov detectors

    Energy Technology Data Exchange (ETDEWEB)

    Muller, Marcio Aparecido; Chinellato, Jose Augusto [Universidade de Campinas (IFGW/UNICAMP), SP (Brazil). Inst. de Fisica Gleb Wataghin

    2011-07-01

    Full text: One of the purposes of the Pierre Auger Collaboration is to study the mass composition of primary cosmic rays. When a cosmic ray collides in the upper atmosphere, depending on the mass composition, we have different numbers of mesons being produced and therefore different amounts of muons at detector level. For example, showers initiated by proton have less muons than showers initiated by iron nucleus. If we can select the muon signal in Cherenkov tanks, we might be able to infer primary composition. To achieve this goal, we will use the so-called 'Muon Jump Method', which aims to discriminate muons from the electromagnetic component, based on the time structure of their FADC signal. Muons produces on average more signal than electrons or gammas and they induce spiky signals whereas the electromagnetic component produce a continuum of small peaks in the FADC traces. Using this information, we estimate the number of particles for each component, by setting filters the time distribution of the shower front. Therefore, we can infer the primary mass composition. Another important point of this study is to compare the predictions of the hadronic interaction models for each component of the shower front. We present an introduction to the main aspects of the 'Muon Jump Method' as well as some preliminary results we achieved by simulating air showers, reconstructing their main features and filtering the signals of each component. (author)

  15. A CMOS Integrating Amplifier for the PHENIX Ring Imaging Cherenkov detector

    Energy Technology Data Exchange (ETDEWEB)

    Wintenberg, A.L.; Jones, J.P. Jr.; Young, G.R. [Oak Ridge National Lab., TN (United States); Moscone, C.G. [Tennessee Univ., Knoxville, TN (United States)

    1997-11-01

    A CMOS integrating amplifier has been developed for use in the PHENIX Ring Imaging Cherenkov (RICH) detector. The amplifier, consisting of a charge-integrating amplifier followed by a variable gain amplifier (VGA), is an element of a photon measurement system comprising a photomultiplier tube, a wideband, gain of 10 amplifier, the integrating amplifier, and an analog memory followed by an ADC and double correlated sampling implemented in software. The integrating amplifier is designed for a nominal full scale input of 160 pC with a gain of 20 mV/pC and a dynamic range of 1000:1. The VGA is used for equalizing gains prior to forming analog sums for trigger purposes. The gain of the VGA is variable over a 3:1 range using a 5 bits digital control, and the risetime is held to approximately 20 ns using switched compensation in the VGA. Details of the design and results from several prototype devices fabricated in 1.2 {micro}m Orbit CMOS are presented. A complete noise analysis of the integrating amplifier and the correlated sampling process is included as well as a comparison of calculated, simulated and measured results.

  16. Gas Cherenkov Detectors For Gamma Ray Measurements At The National Ignition Facility (NIF)

    Science.gov (United States)

    Herrmann, Hans W.; Kim, Y. H.; Zylstra, A. B.; Lopez, F. E.; Griego, J.; Fatherley, V. E.; Oertel, J. A.; Batha, S. H.; Carpenter, A.; Khater, H.; Hernandez, J. E.; Rubery, M. S.; Horsfield, C. J.; Gales, S.; Leatherland, A.; Hilsabeck, T.; Kilkenny, J. D.; Malone, R. M.; Hares, J. D.; Milnes, J.; Shmayda, W. T.

    2016-10-01

    New requirements to improve reaction history and ablator areal density measurements at the NIF necessitate diagnostic capability improvements in sensitivity, temporal and spectral response relative to the existing Gamma Reaction History diagnostic (GRH-6m) located 6 meters from target chamber center (TCC). Relative to GRH-6m, a new DIM-based ``Super'' Gas Cherenkov Detector (GCD) will ultimately provide 200x more sensitivity to DT fusion gamma rays, reduce the effective temporal resolution from 100 to 10 ps and lower the energy threshold from 2.9 to 1.8 MeV. Initially, the existing GCD-3 will be placed into a reentrant well, putting it within 4 meters of TCC. This diagnostic platform will allow assessment of the x-ray radiation background environment within the well which will be fed into the shielding design for the follow-on ``Super'' GCD. It will also enable use of a pulse-dilation PMT (PD-PMT) which has the potential to improve the effective measurement bandwidth by 10x relative to current PMT technology. Initial measurements of both GCD-3 on NIF and a PD-PMT prototype on ORION will be discussed.

  17. Investigating D-T Reaction Spectra with the Gas Cherenkov Detector

    Science.gov (United States)

    Huff, Michael A.; Kim, Yong Ho; McEvoy, Aaron; Young, Carlton S.; Mack, Joe M.; Herrmann, Hans W.; Horsfield, Colin J.

    2010-11-01

    In this study, a new analysis of the gamma ray spectra of the D-T fusion reaction using a Gas Cherenkov Detector (GCD) is presented. The D-T reaction is an essential process to understand for the future of fusion science. The reaction produces a He^5* nucleus that usually decays into a He^4 + n. It has been seen that this reaction produces a 16.75 MeV gamma ray .0025% of the time. The Gamma Ray History (GRH) group at Los Alamos proposes that there is an even less often occurrence where a gamma ray of around 12 MeV is produced. As the truth of this statement would affect the future potential yield of fusion reactors using D-T fuel, it is worth investigating. D-T spectra were obtained by detecting the produced gamma ray with the GCD at the University of Rochester OMEGA laser facility. A GCD response curve, calculated by the Monte Carlo modeling software ACCEPT, was used to forward convolve theoretical spectra into what the theoretical curves would have looked like in the GCD data. Results are presented.

  18. Detection of D-^3He Fusion γ-Rays using Gas Cherenkov Detectors

    Science.gov (United States)

    Kim, Y.; Herrmann, H. W.; Mack, J. M.; Young, C. S.; Hale, G. M.; Evans, S. C.; Sedillo, T. J.; Cahill, A.; Horsfield, C. J.; Rubery, M. S.; Grafil, E.; Stoeffl, W.; Waugh, C.; Rinderknecht, H. G.; Frenje, J. A.; Petrasso, R. D.; Miller, E. Kirk

    2012-10-01

    The high-energy γ-ray from ^3He(d,γ)^5Li reactions has drawn the attention of the nuclear physics and fusion community as a diagnostic signature to study the ^5Li nuclear structure and the D-^3He fusion reaction. In the past, the D-^3He γ-rays have been measured via accelerator-based beam-target experiments and recently in tokamak-based fusion reactors. In this work, we report the detection of D-^3He fusion γ-rays generated from inertial confinement fusion (ICF) implosions at the OMEGA laser facility. The γ-ray signal observed using Gas Cherenkov Detectors (GCD) is proportional to the independently measured 14.7-MeV fusion proton yield and provides a high-bandwidth alternative to fusion protons for D-^3He burn-history measurements. By comparing γ-rays from D-^3He and D-T implosions, we were able to examine (1) similarities in the γ-ray spectra of D-^3He and D-T and (2) disparities in the γ-to-particle branching ratios of D-^3He and D-T. This experimental work motivates further theoretical investigation of the multichannel ^5Li- and ^5He-system.

  19. Use of water-Cherenkov detectors to detect Gamma Ray Bursts at the Large Aperture GRB Observatory (LAGO)

    Energy Technology Data Exchange (ETDEWEB)

    Allard, D. [APC, CNRS et Universite Paris 7 (France); Allekotte, I. [Centro Atomico Bariloche, Instituto Balseiro (Argentina); Alvarez, C. [Facultad de Ciencias Fisico-Matematicas de la BUAP (Mexico); Asorey, H. [Centro Atomico Bariloche, Instituto Balseiro (Argentina); Barros, H. [Laboratorio de Fisica Nuclear, Universidad Simon Bolivar, Caracas (Venezuela, Bolivarian Republic of); Bertou, X. [Centro Atomico Bariloche, Instituto Balseiro (Argentina)], E-mail: bertou@cab.cnea.gov.ar; Burgoa, O. [Instituto de Investigaciones Fisicas, UMSA (Bolivia); Gomez Berisso, M. [Centro Atomico Bariloche, Instituto Balseiro (Argentina); Martinez, O. [Facultad de Ciencias Fisico-Matematicas de la BUAP (Mexico); Miranda Loza, P. [Instituto de Investigaciones Fisicas, UMSA (Bolivia); Murrieta, T.; Perez, G. [Facultad de Ciencias Fisico-Matematicas de la BUAP (Mexico); Rivera, H. [Instituto de Investigaciones Fisicas, UMSA (Bolivia); Rovero, A. [Instituto de Astronomia y Fisica del Espacio (Argentina); Saavedra, O. [Dipartimento di Fisica Generale and INFN, Torino (Italy); Salazar, H. [Facultad de Ciencias Fisico-Matematicas de la BUAP (Mexico); Tello, J.C. [Laboratorio de Fisica Nuclear, Universidad Simon Bolivar, Caracas (Venezuela, Bolivarian Republic of); Ticona Peralda, R.; Velarde, A. [Instituto de Investigaciones Fisicas, UMSA (Bolivia); Villasenor, L. [Facultad de Ciencias Fisico-Matematicas de la BUAP (Mexico); Instituto de Fisica y Matematicas, Universidad de Michoacan (Mexico)

    2008-09-21

    The Large Aperture GRB Observatory (LAGO) project aims at the detection of high energy photons from Gamma Ray Bursts (GRB) using the single particle technique in ground-based water-Cherenkov detectors (WCD). To reach a reasonable sensitivity, high altitude mountain sites have been selected in Mexico (Sierra Negra, 4550 m a.s.l.), Bolivia (Chacaltaya, 5300 m a.s.l.) and Venezuela (Merida, 4765 m a.s.l.). We report on detector calibration and operation at high altitude, search for bursts in 4 months of preliminary data, as well as search for signal at ground level when satellites report a burst.

  20. Performance of a hybrid photon detector prototype with electrostatic cross-focussing and integrated silicon Pixel readout for Cherenkov ring detection

    CERN Document Server

    Alemi, M; Bibby, J H; Campbell, M; Duane, A; Easo, S; Gys, Thierry; Halley, A W; Piedigrossi, D; Puertolas, D; Rosso, E; Simmons, B; Snoeys, W; Websdale, David M; Wotton, S A; Wyllie, Ken H

    1999-01-01

    We report on the first test beam performance of a hybrid photon detector prototype, using binary readout electronics, intended for use in the ring imaging Cherenkov detectors of the LHCb experiment at the CERN Large Hadron Collider. The photon detector is based on a cross-focussed image intensifier tube geometry. The anode consists of a silicon pixel array bump-bonded to a binary readout chip with matching pixel electronics. The detector has been installed in a quarter-scale prototype vessel of the LHCb ring imaging Cherenkov system. Focussed ring images produced by 120 GeV/c negative pions traversing an air radiator have been recorded. The observed light yield and Cherenkov angle resolution are discussed.

  1. Performance of a hybrid photon detector prototype with electrostatic cross-focussing and integrated silicon pixel readout for Cherenkov ring detection

    Energy Technology Data Exchange (ETDEWEB)

    Alemi, M.; Barber, G.; Bibby, J.; Campbell, M.; Duane, A.; Easo, S.; Gys, T.; Halley, A.; Piedigrossi, D.; Puertolas, D.; Rosso, E.; Simmons, B.; Snoeys, W.; Websdale, D.; Wotton, S.; Wyllie, K

    1999-08-01

    We report on the first test beam performance of a hybrid photon detector prototype, using binary readout electronics, intended for use in the ring imaging Cherenkov detectors of the LHCb experiment at the CERN Large Hadron Collider. The photon detector is based on a cross-focussed image intensifier tube geometry. The anode consists of a silicon pixel array bump-bonded to a binary readout chip with matching pixel electronics. The detector has been installed in a quarter-scale prototype vessel of the LHCb ring imaging Cherenkov system. Focussed ring images produced by 120 GeV/c negative pions traversing an air radiator have been recorded. The observed light yield and Cherenkov angle resolution are discussed.

  2. A Prototype Combination TPC Cherenkov Detector with GEM Readout for Tracking and Particle Identification and its Potential Use at an Electron Ion Collider

    CERN Document Server

    Woody, Craig; Majka, Richard; Phipps, Michael; Purschke, Martin; Smirnov, Nikolai

    2015-01-01

    A prototype detector is being developed which combines the functions of a Time Projection Chamber for charged particle tracking and a Cherenkov detector for particle identification. The TPC consists of a 10x10x10 cm3 drift volume where the charge is drifted to a 10x10 cm2 triple GEM detector. The charge is measured on a readout plane consisting of 2x10 mm2 chevron pads which provide a spatial resolution ~ 100 microns per point in the chevron direction along with dE/dx information. The Cherenkov portion of the detector consists of a second 10x10 cm2 triple GEM with a photosensitive CsI photocathode on the top layer. This detector measures Cherenkov light produced in the drift gas of the TPC by high velocity particles which are above threshold. CF4 or CF4 mixtures will be used as the drift gas which are highly transparent to UV light and can provide excellent efficiency for detecting Cherenkov photons. The drift gas is also used as the operating gas for both GEM detectors. The prototype detector has been constr...

  3. Wide field-of-view Cherenkov telescope for the detection of cosmic rays in coincidence with the surface detectors of the extensive air shower array

    CERN Document Server

    Ivanov, A A; Krasilnikov, A D; Petrov, Z E; Pravdin, M I; Sleptsov, I Ye; Timofeev, L V

    2014-01-01

    The Yakutsk array group is developing the wide FOV Cherenkov telescope to be operated in coincidence with the surface detectors of the extensive air shower array. Currently, the engineering prototype of the reflecting telescope with the front-end electronics is designed and assembled to demonstrate the feasibility of a conceived instrument. The status and specifications of the prototype telescope are presented, as well as the modernization program of the Cherenkov light detectors subset of the array measuring ultra-high energy cosmic rays.

  4. Sensitivity of the High Altitude Water Cherenkov Detector to Sources of Multi-TeV Gamma Rays

    CERN Document Server

    Abeysekara, A U; Alvarez, C; Álvarez, J D; Arceo, R; Arteaga-Velázquez, J C; Solares, H A Ayala; Barber, A S; Baughman, B M; Bautista-Elivar, N; Belmont, E; BenZvi, S Y; Berley, D; Rosales, M Bonilla; Braun, J; Caballero-Lopez, R A; Carramiñana, A; Castillo, M; Cotti, U; Cotzomi, J; de la Fuente, E; De León, C; DeYoung, T; Hernandez, R Diaz; Diaz-Velez, J C; Dingus, B L; DuVernois, M A; Ellsworth, R W; Fernandez, A; Fiorino, D W; Fraija, N; Galindo, A; Garcia-Luna, J L; Garcia-Torales, G; Garfias, F; González, L X; González, M M; Goodman, J A; Grabski, V; Gussert, M; Hampel-Arias, Z; Hui, C M; Hüntemeyer, P; Imran, A; Iriarte, A; Karn, P; Kieda, D; Kunde, G J; Lara, A; Lauer, R J; Lee, W H; Lennarz, D; Vargas, H León; Linares, E C; Linnemann, J T; Longo, M; Luna-Garc\\'\\ia, R; Marinelli, A; Martinez, O; Mart\\'\\inez-Castro, J; Matthews, J A J; Miranda-Romagnoli, P; Moreno, E; Mostafá, M; Nava, J; Nellen, L; Newbold, M; Noriega-Papaqui, R; Oceguera-Becerra, T; Patricelli, B; Pelayo, R; Pérez-Pérez, E G; Pretz, J; Rivière, C; Rosa-González, D; Salazar, H; Salesa, F; Sandoval, A; Santos, E; Schneider, M; Silich, S; Sinnis, G; Smith, A J; Sparks, K; Springer, R W; Taboada, I; Toale, P A; Tollefson, K; Torres, I; Ukwatta, T N; Villaseñor, L; Weisgarber, T; Westerhoff, S; Wisher, I G; Wood, J; Yodh, G B; Younk, P W; Zaborov, D; Zepeda, A; Zhou, H

    2013-01-01

    The High Altitude Water Cherenkov (HAWC) observatory is an array of large water Cherenkov detectors sensitive to gamma rays and hadronic cosmic rays in the energy band between 100 GeV and 100 TeV. The observatory will be used to measure high-energy protons and cosmic rays via detection of the energetic secondary particles reaching the ground when one of these particles interacts in the atmosphere above the detector. HAWC is under construction at a site 4100 meters above sea level on the northern slope of the volcano Sierra Negra, which is located in central Mexico at 19 degrees N latitude. It is scheduled for completion in 2014. In this paper we estimate the sensitivity of the HAWC instrument to point-like and extended sources of gamma rays. The source fluxes are modeled using both unbroken power laws and power laws with exponential cutoffs. HAWC, in one year, is sensitive to point sources with integral power-law spectra as low as 5x10^-13 cm^-2 sec^-1 above 2 TeV (approximately 50 mCrab) over 5 sr of the sky...

  5. Identification of 90Sr/40K Based on Cherenkov Detector for Recovery from the Fukushima Nuclear Accident

    Science.gov (United States)

    Ito, Hiroshi; Han, Soorim; Kobayashi, Atsushi; Kaneko, Naomi; Kawai, Hideyuki; Tabata, Makoto

    Although five years have passed since the Fukushima nuclear accident of 2011, the local fisheries have yet to recover from its effects. One reason for this situation is the difficulty of measuring the radioactivity owing to 90Sr in seafood. After the accident, the radioactivity due to Cs isotopes in samples was measured with precision, which facilitated the enforcement of the maximum concentration of Cs radioisotopes in food at 100 Bq/kg, as defined by the Ministry of Health, Labour and Welfare in Japan. However, 90Sr is more dangerous than Cs isotopes because it has an effective half-life of 18 years and accumulates in the bone. The radioactivity owing to 90Sr in a sample is difficult to measure because the beta rays from 137Cs or 40K also contribute to the signal. When measured based on the endpoint pulse height as determined by a conventional survey meter, the beta ray signal from 90Y (daughter of 90Sr) cannot be differentiated from the beta rays from other sources. To overcome this difficulty, in this study, we develop a Cherenkov detector based on a silica aerogel with a refractive index of 1.034 that can identify beta rays from 90Y within a background of beta rays from 137Cs and 40K. This instrument involves a detector that is sensitive to beta rays from 90Sr but less sensitive to radiation from other sources. This detector comprises a trigger counter that uses scintillating fibers, an aerogel Cherenkov counter with wavelength-shifting fibers, and a veto counter to suppress cosmic rays. We characterize the detector using a 90Sr source, 137Cs source, and pure potassium chloride reagent of 16.6 Bq/g, where the radioactivity of natural 40K is estimated to be 31.7 Bq/g. The following results are obtained: the absolute detection efficiency for 90Sr, 137Cs, and 40K is [2.24 ± 0.01 (stat) ± 0.44 (sys)] × 10-3 Bq-1 s-1, [1.27 ± 0.08 (stat) ± 0.25 (sys)] × 10-6 Bq-1 s-1, and [5.05 ± 2.40 (stat) ± 0.15 (sys)] × 10-5 Bq-1 s-1, respectively. To aid in the

  6. A novel background reduction strategy for high level triggers and processing in gamma-ray Cherenkov detectors

    CERN Document Server

    Cabras, G; De Lotto, B; De Maria, M M; De Sabata, F; Mansutti, O; Frailis, M; Persic, M; Bigongiari, C; Doro, M; Mariotti, M; Peruzzo, L; Saggion, A; Scalzotto, V; Paoletti, R; Scribano, A; Turini, N; Moralejo, A; Tescaro, D

    2008-01-01

    Gamma ray astronomy is now at the leading edge for studies related both to fundamental physics and astrophysics. The sensitivity of gamma detectors is limited by the huge amount of background, constituted by hadronic cosmic rays (typically two to three orders of magnitude more than the signal) and by the accidental background in the detectors. By using the information on the temporal evolution of the Cherenkov light, the background can be reduced. We will present here the results obtained within the MAGIC experiment using a new technique for the reduction of the background. Particle showers produced by gamma rays show a different temporal distribution with respect to showers produced by hadrons; the background due to accidental counts shows no dependence on time. Such novel strategy can increase the sensitivity of present instruments.

  7. Study of electron beams within ISTTOK tokamak by means of a multi-channel Cherenkov detector; their correlation with hard X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Jakubowski, L., E-mail: Lech.Jakubowski@ipj.gov.p [Andrzej Soltan Institute for Nuclear Studies, 05-400 Otwock-Swierk (Poland); Malinowski, K.; Sadowski, M.J.; Zebrowski, J. [Andrzej Soltan Institute for Nuclear Studies, 05-400 Otwock-Swierk (Poland); Plyusnin, V.V. [Association Euratom/IST, Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Av. Rovisco Pais, 1049-001 Lisboa (Portugal); Rabinski, M. [Andrzej Soltan Institute for Nuclear Studies, 05-400 Otwock-Swierk (Poland); Fernandes, H.; Silva, C.; Duarte, P. [Association Euratom/IST, Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Av. Rovisco Pais, 1049-001 Lisboa (Portugal); Jakubowski, M.J. [Andrzej Soltan Institute for Nuclear Studies, 05-400 Otwock-Swierk (Poland)

    2010-11-11

    The paper describes experimental studies of electron beams emitted from a plasma torus within the ISTTOK tokamak, which were performed by means of a new four-channel detector of the Cherenkov type. A range of electron energy was estimated. There were also measured hard X-rays, and their correlation with the fast run-away electron beams was investigated experimentally.

  8. Measuring extensive air showers with Cherenkov light detectors of the Yakutsk array: the energy spectrum of cosmic rays

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, A A; Knurenko, S P; Sleptsov, I Ye [Shafer Institute for Cosmophysical Research and Aeronomy, Yakutsk 677980 (Russian Federation)], E-mail: ivanov@ikfia.ysn.ru

    2009-06-15

    The energy spectrum of cosmic rays in the range E{approx}10{sup 15} eV to 6x10{sup 19} eV is studied in this paper using air Cherenkov light detectors of the Yakutsk array. The total flux of photons produced by the relativistic electrons (including positrons as well, hereafter) of extensive air showers in the atmosphere is used as an energy estimator of the primary particle initiating a shower. The resultant differential flux of cosmic rays exhibits, in agreement with previous measurements, a knee and ankle feature at energies of 3x10{sup 15} and {approx}10{sup 19} eV, respectively. A comparison of observational data with simulations is made in the knee and ankle regions in order to choose the models of galactic and extragalactic components of cosmic rays that describe well the energy spectrum measured.

  9. Development of a 144-channel Hybrid Avalanche Photo-Detector for Belle II ring-imaging Cherenkov counter with an aerogel radiator

    Energy Technology Data Exchange (ETDEWEB)

    Nishida, S., E-mail: shohei.nishida@kek.jp [High Energy Accelerator Research Organization (KEK), Tsukuba (Japan); Adachi, I. [High Energy Accelerator Research Organization (KEK), Tsukuba (Japan); Hamada, N. [Toho University, Funabashi (Japan); Hara, K. [High Energy Accelerator Research Organization (KEK), Tsukuba (Japan); Iijima, T. [Nagoya University, Nagoya (Japan); Iwata, S.; Kakuno, H. [Tokyo Metropolitan University, Hachioji (Japan); Kawai, H. [Chiba University, Chiba (Japan); Korpar, S.; Krizan, P. [Jozef Stefan Institute, Ljubljana (Slovenia); Ogawa, S. [Toho University, Funabashi (Japan); Pestotnik, R.; Ŝantelj, L.; Seljak, A. [Jozef Stefan Institute, Ljubljana (Slovenia); Sumiyoshi, T. [Tokyo Metropolitan University, Hachioji (Japan); Tabata, M. [Chiba University, Chiba (Japan); Tahirovic, E. [Jozef Stefan Institute, Ljubljana (Slovenia); Yoshida, K. [Tokyo Metropolitan University, Hachioji (Japan); Yusa, Y. [Niigata University, Niigata (Japan)

    2015-07-01

    The Belle II detector, a follow up of the very successful Belle experiment, is under construction at the SuperKEKB electron–positron collider at KEK in Japan. For the PID system in the forward region of the spectrometer, a proximity-focusing ring-imaging Cherenkov counter with an aerogel radiator is being developed. For the position sensitive photon sensor, a 144-channel Hybrid Avalanche Photo-Detector has been developed with Hamamatsu Photonics K.K. In this report, we describe the specification of the Hybrid Avalanche Photo-Detector and the status of the mass production.

  10. Design of the TORCH detector: A Cherenkov based Time-of-Flight system for particle identification

    CERN Document Server

    AUTHOR|(CDS)2078663; Rademacker, Jonas

    The LHCb detector at the LHC collider has been very successfully operated over the past years, providing new and profound insights into the Standard Model, in particular through study of $b$-hadrons to achieve a better understanding of CP violation. One of the key components of LHCb is its particle identification system, comprised of two RICH detectors, which allow for high precision separation of particle species over a large momentum range. In order to retain and improve the performance of the particle identification system in light of the LHCb upgrade, the TORCH detector has been proposed to supplement the RICH system at low momentum (2-10 GeV/c). The TORCH detector provides (charged) particle identification through precision timing of particles passing through it. Assuming a known momentum from the tracking, it is possible to derive the species of a particle from the time of flight from its primary vertex. This measurement is achieved by timing and combining photons generated in a solid radiator. The geom...

  11. An aerogel Cherenkov detector for multi-GeV photon detection with low sensitivity to neutrons

    CERN Document Server

    Maeda, Y; Masuda, T; Morii, H; Naito, D; Nakajima, Y; Nanjo, H; Nomura, T; Sasao, N; Seki, S; Shiomi, K; Sumida, T; Tajima, Y

    2014-01-01

    We describe a novel photon detector which operates under an intense flux of neutrons. It is composed of lead-aerogel sandwich counter modules. Its salient features are high photon detection efficiency and blindness to neutrons. As a result of Monte Carlo (MC) simulations, the efficiency for photons with the energy larger than 1 GeV is expected to be higher than 99.5% and that for 2 GeV/$c$ neutrons less than 1%. The performance on the photon detection under such a large flux of neutrons was measured for a part of the detector. It was confirmed that the efficiency to photons with the energy $>$1 GeV was consistent with the MC expectation within 8.2% uncertainty.

  12. The Aerogel Cherenkov Detector for the SHMS magnetic spectrometer in Hall C at Jefferson Lab

    CERN Document Server

    Horn, T; Ali, S; Asaturyan, A; Carmignotto, M A P; Dittmann, A; Dutta, D; Ent, R; Hlavin, N; Illieva, Y; Mkrtchyan, A; Nadel-Turonski, P; Pegg, I L; Ramos, A; Reinhold, J; Sapkota, I; Tadevosyan, V; Zhamkochyan, S; Wood, S A

    2016-01-01

    Hadronic reactions producing strange quarks such as exclusive or semi-inclusive kaon production, play an important role in studies of hadron structure and the dynamics that bind the most basic elements of nuclear physics. The small-angle capability of the new Super High Momentum Spectrometer (SHMS) in Hall C, coupled with its high momentum reach - up to the anticipated 11-GeV beam energy in Hall C - and coincidence capability with the well-understood High Momentum Spectrometer, will allow for probes of such hadron structure involving strangeness down to the smallest distance scales to date. To cleanly select the kaons, a threshold aerogel Cerenkov detector has been constructed for the SHMS. The detector consists of an aerogel tray followed by a diffusion box. Four trays for aerogel of nominal refractive indices of n=1.030, 1.020, 1.015 and 1.011 were constructed. The tray combination will allow for identification of kaons from 1 GeV/c up to 7.2 GeV/c, reaching 10^-2 proton and 10^-3 pion rejection, with kaon ...

  13. Solar neutrino results (from radio-chemical and water Cherenkov detectors)

    CERN Document Server

    Suzuki, Y

    2001-01-01

    Recent results on solar neutrino measurements are discussed. The results from radio-chemical experiments are briefly summarized. The new data from 1117 effective days of Super-Kamiokande shows that the spectrum shape agrees with that expected from the convoluted effect of the sup 8 B-neutrino spectrum, the recoil electron spectrum of neutrino electron scattering and the detector responses and that there is a 3.4% difference between the day- and night-time fluxes, but statistically not significant. There is no strong smoking gun evidence for oscillation yet, however those precise measurements of the spectrum shape and day/night fluxes have given a constraint on the oscillation parameters, indicating at 95% confidence level that the large mixing angles solutions (MSW LMA and LOW) are preferable.

  14. Measurements of Coherent Cherenkov Radiation in Rock Salt: Implications for GZK Neutrino Underground Detector

    CERN Document Server

    Milincic, R; Saltzberg, D; Field, R C; Guillian, G; Walz, D; Williams, D

    2005-01-01

    We report on further SLAC measurements of the Askaryan effect: coherent radio emission from charge asymmetry in electromagnetic cascades. We used synthetic rock salt as the dielectric medium, with cascades produced by GeV bremsstrahlung photons at the Final Focus Test Beam. We extend our prior discovery measurements to a wider range of parameter space and explore the effect in a dielectric medium of great potential interest to large scale ultra-high energy neutrino detectors: rock salt. We observed strong coherent pulsed radio emission over a frequency band from 0.2-15 GHz. A grid of embedded dual-polarization antennas was used to confirm the linear polarization and track the change of direction of the electric-field vector around the shower. Coherence was observed over 4 orders of magnitude of shower energy. The frequency dependence of the radiation was tested over two orders of magnitude of UHF and microwave frequencies. Based on these results we have performed a simulation of a realistic GZK neutrino teles...

  15. GPU-based low-level trigger system for the standalone reconstruction of the ring-shaped hit patterns in the RICH Cherenkov detector of NA62 experiment

    Science.gov (United States)

    Ammendola, R.; Biagioni, A.; Chiozzi, S.; Cretaro, P.; Cotta Ramusino, A.; Di Lorenzo, S.; Fantechi, R.; Fiorini, M.; Frezza, O.; Gianoli, A.; Lamanna, G.; Lo Cicero, F.; Lonardo, A.; Martinelli, M.; Neri, I.; Paolucci, P. S.; Pastorelli, E.; Piandani, R.; Piccini, M.; Pontisso, L.; Rossetti, D.; Simula, F.; Sozzi, M.; Vicini, P.

    2017-03-01

    This project aims to exploit the parallel computing power of a commercial Graphics Processing Unit (GPU) to implement fast pattern matching in the Ring Imaging Cherenkov (RICH) detector for the level 0 (L0) trigger of the NA62 experiment. In this approach, the ring-fitting algorithm is seedless, being fed with raw RICH data, with no previous information on the ring position from other detectors. Moreover, since the L0 trigger is provided with a more elaborated information than a simple multiplicity number, it results in a higher selection power. Two methods have been studied in order to reduce the data transfer latency from the readout boards of the detector to the GPU, i.e., the use of a dedicated NIC device driver with very low latency and a direct data transfer protocol from a custom FPGA-based NIC to the GPU. The performance of the system, developed through the FPGA approach, for multi-ring Cherenkov online reconstruction obtained during the NA62 physics runs is presented.

  16. Particle Identification with Cherenkov detectors in the 2011 CALICE Tungsten Analog Hadronic Calorimeter Test Beam at the CERN SPS

    CERN Document Server

    Dannheim, D; Klempt, W; Lucaci Timoce, A; van der Kraaij, E

    2013-01-01

    In 2011 the CALICE Tungsten Analog Hadronic Calorimeter prototype (W-AHCAL) was exposed to mixed beams of electrons, pions, kaons and protons with momenta from 10 to 300 GeV in the CERN SPS H8 beam line. The selection of pion, kaon and proton samples is based on the information obtained from two Cherenkov threshold counters. This note presents the strategy for the particle identification, as well as the calibration, operation and analysis of the Cherenkov counters. Efficiency and sample-purity estimates are given for the data selected for the W-AHCAL data analysis.

  17. DELPHI's Ring Imaging Cherenkov Chamber

    CERN Multimedia

    1989-01-01

    The hundreds of mirrors around this Ring Imaging Cherenkov Chamber reflect cones of light created by fast moving particles to a detector. The velocity of a particle can be measured by the size of the ring produced on the detector. DELPHI, which ran from 1989 to 2000 on the LEP accelerator, was primarily concerned with particle identification.

  18. Underground Water Cherenkov Muon Detector Array with the Tibet Air Shower Array for Gamma-Ray Astronomy in the 100 TeV Region

    CERN Document Server

    Amenomori, M; Bi, X J; Chen, D; Cui, S W; Feng Zhao Yang; Danzengluobu; Ding, L K; Feng Cun Feng; Feng, Z; Feng, Z Y; Gao, X Y; Geng, Q X; Guo, H W; He, H H; He, M; Hibino, K; Hotta, N; Haibing, H; Hu, H B; Huang, J; Jia, H Y; Kajino, F; Kasahara, K; Katayose, Y; Kato, C; Kawata, K; Labaciren; Le, G M; Li, A F; Li, J Y; Lü, H; Lu, S L; Meng, X R; Mizutani, K; Mu, J; Munakata, K; Nagai, A; Nanj, H; Nishizawa, M; Ohnishi, M; Ohta, I; Onuma, H; Ouchi, T; Ozawa, S; Ren, J R; Saitô, T; Saito, T Y; Sakata, M; Sako, T K; Sasaki, T; Shibata, M; Shiomi, A; Shirai, T; Sugimoto, H; Takita, M; Tan, Y H; Tateyama, N; Tori, S; Wang, B; Tsuchiya, H; Udo, S; Wang, X; Wang, Y G; Wu, H R; Xue Liang; Yamamoto, Y; Yan, C T; Yang, X C; Yasue, S; Ye, Z H; Yu, G C; Yuan, A F; Yuda, T; Zhang, H M; Zhamg, N J; Zhamg, X, Y; Zhamg, Y; Zhamg, Yi; Zha Xisang Zhu; Zhou, X X; al, et

    2006-01-01

    We propose to build a large water-Cherenkov-type muon-detector array (Tibet MD array) around the 37,000 m$^{2}$ Tibet air shower array (Tibet AS array) already constructed at 4,300 m above sea level in Tibet, China. Each muon detector is a waterproof concrete pool, 6 m wide $\\times$ 6 m long $\\times$ 1.5 m deep in size, equipped with a 20 inch-in-diameter PMT. The Tibet MD array consists of 240 muon detectors set up 2.5 m underground. Its total effective area will be 8,640 m$^{2}$ for muon detection. The Tibet MD array will significantly improve gamma-ray sensitivity of the Tibet AS array in the 100 TeV region (10-1000 TeV) by means of gamma/hadron separation based on counting the number of muons accompanying an air shower. The Tibet AS+MD array will have the sensitivity to gamma rays in the 100 TeV region by an order of magnitude better than any other previous existing detectors in the world.

  19. Cherenkov radiation; La radiation Cerenkov

    Energy Technology Data Exchange (ETDEWEB)

    Hubert, P. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    When the radioactivity has been discovered, it was observed by researchers that different materials as mineral salts or solutions were emitting a weak light when submitted to radioactivity beams. At the beginning it has been thought that it was fluorescent light. In 1934, Cherenkov, a russian physicist, worked on the luminescence of uranyl salts solutions caused by gamma radiation and observed a very weak light was emitted by pure liquid. After further studies, he concluded that this phenomena was different from fluorescence. Since then, it has been called Cherenkov effect. This blue light emission is produced when charged particles are going through a transparent medium with an upper velocity than light velocity. This can happen only in medium with large refractive index as water or glass. It also presents its different properties discovered afterwards. The different applications of the Cherenkov radiation are discussed as counting techniques for radiation detectors or comic ray detectors. (M.P.)

  20. Detection of atmospheric Cherenkov radiation using solar heliostat mirrors

    CERN Document Server

    Ong, R A

    1996-01-01

    The gamma-ray energy region between 20 and 250 GeV is largely unexplored. Ground-based atmospheric Cherenkov detectors offer a possible way to explore this region, but large Cherenkov photon collection areas are needed to achieve low energy thresholds. This paper discusses the development of a Cherenkov detector using the heliostat mirrors of a solar power plant as the primary collector. As part of this development, we built a prototype detector consisting of four heliostat mirrors and used it to record atmospheric Cherenkov radiation produced in extensive air showers created by cosmic ray particles.

  1. QUEST: wide angle Cherenkov light measurements at EAS-TOP

    Science.gov (United States)

    EAS-Top Collaboration; Korosteleva, E. E.; Kuzmichev, L. A.; Prosin, V. V.; Lubsandorzhiev, B. K.

    Wide angle Cherenkov light detectors based upon the QUASAR-370 photo-multipliers have been installed on five Cherenkov telescopes of the EAS-TOP array to study the energy spectrum and composition of primary cosmic rays around the knee . The energy threshold of quasars array was close to that of EAS-TOP electromagnetic detectors array. The first results of joint analysis of Cherenkov and electromagnetic data together with the adequate CORSIKA simulation results are discussed.

  2. Photosensitive gas detectors for the ring-imaging Cherenkov (RICH) technique and the DELPHI barrel RICH prototype

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, R.; Berst, J.D.; Christophel, E.; Guyonnet, J.L.; Baillon, P.; Bosteels, M.; Passardi, G.; Besch, H.J.; Seguinot, J.; Tocqueville, J.

    1986-12-01

    After a short introduction to the ring-imaging technique, the principal types of photosensitive gas detectors are discussed. In the second part, status and results of the DELPHI barrel RICH prototype are presented. A short description of a possible very fast RICH for future hadron colliders is given.

  3. Wide-angle cherenkov telescope prototype preliminary data

    Science.gov (United States)

    Timofeev, Lev; Anatoly, Ivanov

    2016-07-01

    This report presents an observation method of Cherenkov light from extensive air showers (EAS) generated by cosmic rays (CRs) above 10^16eV and preliminary observations. The interest in Cherenkov light differential detectors of EAS is caused by the possibility to measure the depth of cascade maximum, Xmax, and/or the shower age via angular and temporal distributions of the Cherenkov signal. In particular, it was shown using EAS model simulations that the pulse width measured at the periphery of the shower, r > 300 m, at sea level is pronouncedly connected with Xmax. Cherenkov detector is a wide-angle telescope working in coincidence with scintillation detectors, integral and differential Cherenkov detectors Yakutsk complex EAS.

  4. Measurement of the Muon Atmospheric Production Depth with the Water Cherenkov Detectors of the Pierre Auger Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Molina Bueno, Laura [Univ. of Granada (Spain)

    2015-09-01

    Ultra-high-energy cosmic rays (UHECR) are particles of uncertain origin and composition, with energies above 1 EeV (1018 eV or 0.16 J). The measured flux of UHECR is a steeply decreasing function of energy. The largest and most sensitive apparatus built to date to record and study cosmic ray Extensive Air Showers (EAS) is the Pierre Auger Observatory. The Pierre Auger Observatory has produced the largest and finest amount of data ever collected for UHECR. A broad physics program is being carried out covering all relevant topics of the field. Among them, one of the most interesting is the problem related to the estimation of the mass composition of cosmic rays in this energy range. Currently the best measurements of mass are those obtained by studying the longitudinal development of the electromagnetic part of the EAS with the Fluorescence Detector. However, the collected statistics is small, specially at energies above several tens of EeV. Although less precise, the volume of data gathered with the Surface Detector is nearly a factor ten larger than the fluorescence data. So new ways to study composition with data collected at the ground are under investigation. The subject of this thesis follows one of those new lines of research. Using preferentially the time information associated with the muons that reach the ground, we try to build observables related to the composition of the primaries that initiated the EAS. A simple phenomenological model relates the arrival times with the depths in the atmosphere where muons are produced. The experimental confirmation that the distributions of muon production depths (MPD) correlate with the mass of the primary particle has opened the way to a variety of studies, of which this thesis is a continuation, with the aim of enlarging and improving its range of applicability. We revisit the phenomenological model which is at the root of the analysis and discuss a new way to improve some aspects of the model. We carry

  5. Particle identification by Cherenkov and transition radiation

    Energy Technology Data Exchange (ETDEWEB)

    Gilmore, R.S.

    1980-09-01

    The Cherenkov counter has a role as a particle identifier for velocities which are too high for Time-of-Flight to be used, and too low for transition radiation detectors to give a useable signal. In beam lines the compensated differential counter is capable of giving the best resolution, but at high momenta the restriction on the spread of particle directions gives unacceptable limits on the beam acceptance. The transition radiation detectors being developed to identify hadrons at relatively low momentum do not have this restriction and might be used instead. For particles produced in an interaction, the ring imaging type of Cherenkov should give the best coverage for multiparticle events, but a threshold counter is much simpler, cheaper and faster where it can give adequate separation. Again at high values of ..gamma.. the resolution of Cherenkov counters will fail and some form of transition radiation detector will be necessary.

  6. NICHE: The Non-Imaging CHErenkov Array

    CERN Document Server

    Bergman, Douglas

    2012-01-01

    The accurate measurement of the Cosmic Ray (CR) nuclear composition around and above the Knee (~ 10^15.5 eV) has been difficult due to uncertainties inherent to the measurement techniques and/or dependence on hadronic Monte Carlo simulation models required to interpret the data. Measurement of the Cherenkov air shower signal, calibrated with air fluorescence measurements, offers a methodology to provide an accurate measurement of the nuclear composition evolution over a large energy range. NICHE will use an array of widely-spaced, non-imaging Cherenkov counters to measure the amplitude and time-spread of the air shower Cherenkov signal to extract CR nuclear composition measurements and to cross-calibrate the Cherenkov energy and composition measurements with TA/TALE fluorescence and surface detector measurements.

  7. Fast Cherenkov model of optical photons generation and transportation

    CERN Document Server

    The ATLAS collaboration

    2017-01-01

    This note describes the technical details of Fast Cherenkov model of optical photons generation and transportation: in particular, the mechanism of Cherenkov photons transportation through the straight bar geometry. As an example of usage, the implemetation of the method inside Quartic detector simulation in GEANT4 will be presented and compared to the nominal results.

  8. Development of a custom on-line ultrasonic vapour analyzer/flowmeter for the ATLAS inner detector, with application to gaseous tracking and Cherenkov detectors

    CERN Document Server

    Bates, R; Berry, S; Berthoud, J; Bitadze, A; Bonneau, P; Botelho-Direito, J; Bousson, N; Boyd, G; Bozza, G; Da Riva, E; Degeorge, C; DiGirolamo, B; Doubek, M; Godlewski, J; Hallewell, G; Katunin, S; Lombard, D; Mathieu, M; McMahon, S; Nagai, K; Perez-Rodriguez, E; Rossi, C; Rozanov, A; Vacek, V; Vitek, M; Zwalinski, L

    2013-01-01

    Precision sound velocity measurements can simultaneously determine binary gas composition and flow. We have developed an analyzer with custom electronics, currently in use in the ATLAS inner detector, with numerous potential applications. The instrument has demonstrated ~0.3% mixture precision for C3F8/C2F6 mixtures and < 10-4 resolution for N2/C3F8 mixtures. Moderate and high flow versions of the instrument have demonstrated flow resolutions of +/- 2% F.S. for flows up to 250 l.min-1, and +/- 1.9% F.S. for linear flow velocities up to 15 ms-1; the latter flow approaching that expected in the vapour return of the thermosiphon fluorocarbon coolant recirculator being built for the ATLAS silicon tracker.

  9. An Experiment to Demonstrate Cherenkov / Scintillation Signal Separation

    CERN Document Server

    Caravaca, J; Land, B J; Wallig, J; Yeh, M; Gann, G D Orebi

    2016-01-01

    The ability to separately identify the Cherenkov and scintillation light components produced in scintillating mediums holds the potential for a major breakthrough in neutrino detection technology, allowing development of a large, low-threshold, directional detector with a broad physics program. The CHESS (CHErenkov / Scintillation Separation) experiment employs an innovative detector design with an array of small, fast photomultiplier tubes and state-of-the-art electronics to demonstrate the reconstruction of a Cherenkov ring in a scintillating medium based on photon hit time and detected photoelectron density. This paper describes the physical properties and calibration of CHESS along with first results. The ability to reconstruct Cherenkov rings is demonstrated in a water target, and a time precision of 338 +/- 12 ps FWHM is achieved. Monte Carlo based predictions for the ring imaging sensitivity with a liquid scintillator target predict an efficiency for identifying Cherenkov hits of 94 +/- 1% and 81 +/- 1...

  10. Progress on Cherenkov Reconstruction in MICE

    CERN Document Server

    Kaplan, Daniel M; Rajaram, Durga; Winter, Miles; Cremaldi, Lucien; Sanders, David; Summers, Don

    2016-01-01

    Two beamline Cherenkov detectors (Ckov-a,-b) support particle identification in the MICE beamline. Electrons and high-momentum muons and pions can be identified with good efficiency. We report on the Ckov-a,-b performance in detecting pions and muons with MICE Step I data and derive an upper limit on the pion contamination in the standard MICE muon beam.

  11. The High-Altitude Water Cherenkov Observatory: First Light

    Science.gov (United States)

    Weisgarber, Thomas

    2013-04-01

    The High-Altitude Water Cherenkov (HAWC) Observatory is under construction at Sierra Negra in the state of Puebla in Mexico. Operation began in September 2012, with the first 30 out of the final 300 water Cherenkov detectors deployed and in data acquisition. The HAWC Observatory is designed to record particle air showers from gamma rays and cosmic rays with TeV energies. Though the detector is only 10% complete, HAWC is already the world's largest water Cherenkov detector in the TeV band. In this presentation, I will summarize the performance of the detector to date and discuss preliminary observations of cosmic-ray and gamma-ray sources. I will also describe deployment plans for the remainder of the detector and outline prospects for TeV observations in the coming year.

  12. Optical and radiographical characterization of silica aerogel for Cherenkov radiator

    CERN Document Server

    Tabata, Makoto; Hatakeyama, Yoshikiyo; Kawai, Hideyuki; Morita, Takeshi; Nishikawa, Keiko

    2012-01-01

    We present optical and X-ray radiographical characterization of silica aerogels with refractive index from 1.05 to 1.07 for a Cherenkov radiator. A novel pin-drying method enables us to produce highly transparent hydrophobic aerogels with high refractive index by shrinking wet-gels. In order to investigate the uniformity in the density (i.e., refractive index) of an individual aerogel monolith, we use the laser Fraunhofer method, an X-ray absorption technique, and Cherenkov imaging by a ring imaging Cherenkov detector in a beam test. We observed an increase in density at the edge of the aerogel tiles, produced by pin-drying.

  13. Results from the 1997 run of the LHCb ring imaging Cherenkov test-beam

    CERN Document Server

    Halley, A; Teixeira-Dias, P; Wilkinson, G; Wilkinson, Guy

    1998-01-01

    Analysis results of data from the ring imaging Cherenkov test-beam using hybrid photo diodes are presented. Details are given of the geometrical arrangement of the prototype and data-taking conditions, together with results of simulation and studies of the detector performance, photon yield and Cherenkov angle resolution using different radiators. Good agreement with simulation is found for both gas and aerogel photon yield calculations and the observed Cherenkov angle resolution.1

  14. Wavelength-shifted Cherenkov radiators

    Science.gov (United States)

    Krider, E. P.; Jacobson, V. L.; Pifer, A. E.; Polakos, P. A.; Kurz, R. J.

    1976-01-01

    The scintillation and Cherenkov responses of plastic Cherenkov radiators containing different wavelength-shifting fluors in varying concentrations have been studied in beams of low energy protons and pions. For cosmic ray applications, where large Cherenkov to scintillation ratios are desired, the optimum fluor concentrations are 0.000025 by weight or less.

  15. Cherenkov radiation in moving medium

    OpenAIRE

    2010-01-01

    Cherenkov radiation in uniformly moving homogenous isotropic medium without dispersion is studied. Formula for the spectrum of Cherenkov radiation of fermion was derived for the case when the speed of the medium is less than the speed of light in this medium at rest. The properties of Cherenkov spectrum are investigated.

  16. Exploration of a 100 TeV gamma-ray northern sky using the Tibet air-shower array combined with an underground water-Cherenkov muon-detector array

    CERN Document Server

    Sako, T K; Ohnishi, M; Shiomi, A; Takita, M; Tsuchiya, H

    2009-01-01

    Aiming to observe cosmic gamma rays in the 10 - 1000 TeV energy region, we propose a 10000 m^2 underground water-Cherenkov muon-detector (MD) array that operates in conjunction with the Tibet air-shower (AS) array. Significant improvement is expected in the sensitivity of the Tibet AS array towards celestial gamma-ray signals above 10 TeV by utilizing the fact that gamma-ray-induced air showers contain far fewer muons compared with cosmic-ray-induced ones. We carried out detailed Monte Carlo simulations to assess the attainable sensitivity of the Tibet AS+MD array towards celestial TeV gamma-ray signals. Based on the simulation results, the Tibet AS+MD array will be able to reject 99.99% of background events at 100 TeV, with 83% of gamma-ray events remaining. The sensitivity of the Tibet AS+MD array will be ~20 times better than that of the present Tibet AS array around 20 - 100 TeV. The Tibet AS+MD array will measure the directions of the celestial TeV gamma-ray sources and the cutoffs of their energy spectr...

  17. A new air-Cherenkov array at the South Pole

    CERN Document Server

    Dickinson, J E; Hart, S P; Hill, G C; Hinton, J A; Lloyd-Evans, J; Potter, D; Pryke, C L; Rochester, K; Schwarz, R; Watson, A A

    2000-01-01

    VULCAN comprises a 9 element array of air-Cherenkov radiation detectors established at the South Pole. VULCAN operates in coincidence with the air-shower array SPASE-2 and the two Antarctic Muon And Neutrino Detector Arrays, AMANDA A and B, supplementing the data gathered by these instruments with a measurement of the lateral distribution of air-Cherenkov light from extensive air-showers. An overview of the aims and methods of the whole coincidence experiment (SPASE-2, VULCAN and AMANDA) can be found in an accompanying paper (Dickinson et al., Nucl. Instr. and Meth. A (1999), to be published).

  18. Statistical properties of Cherenkov and quasi-Cherenkov superradiance

    CERN Document Server

    Anishchenko, S V

    2016-01-01

    We consider the effects of shot noise and particle energy spread on statistical properties of Cherenkov and quasi-Cherenkov superradiance emitted by a relativistic electron beam. In the absence of energy spread, we have found the root-mean-square deviations of both peak radiated power and instability growth time as a function of the number of particles. It is shown that energy spread can lead to a sharp drop in the radiated power of Cherenkov and quasi-Cherenkov superradiance at high currents.

  19. Tunable femtosecond Cherenkov fiber laser

    DEFF Research Database (Denmark)

    Liu, Xiaomin; Svane, Ask Sebastian; Lægsgaard, Jesper

    2014-01-01

    We demonstrate electrically-tunable femtosecond Cherenkov fiber laser output at the visible range. Using an all-fiber, self-starting femtosecond Yb-doped fiber laser as the pump source and nonlinear photonic crystal fiber link as the wave-conversion medium, ultrafast, milliwatt-level, tunable...... and spectral isolated Cherenkov radiation at visible wavelengths are reported. Such a femtosecond Cherenkov laser source is promising for practical biophotonics applications....

  20. Characteristics of Cherenkov radiation in naturally occurring ice

    Science.gov (United States)

    Mikkelsen, R. E.; Poulsen, T.; Uggerhøj, U. I.; Klein, S. R.

    2016-03-01

    We revisit the theory of Cherenkov radiation in uniaxial crystals. Historically, a number of flawed attempts have been made at explaining this radiation phenomenon, and a consistent error-free description is nowhere available. We apply our calculation to a large modern day telescope—IceCube. Located in Antarctica, this detector makes use of the naturally occurring ice as a medium to generate Cherenkov radiation. However, due to the high pressure at the depth of the detector site, large volumes of hexagonal ice crystals are formed. We calculate how this affects the Cherenkov radiation yield and angular dependence. We conclude that the effect is small, at most about a percent, and would only be relevant in future high-precision instruments like e.g. Precision IceCube Next Generation Upgrade (PINGU). For radio-Cherenkov experiments which use the presence of a clear Cherenkov cone to determine the arrival direction, any variation in emission angle will directly and linearly translate into a change in apparent neutrino direction. In closing, we also describe a simple experiment to test this formalism and calculate the impact of anisotropy on light yields from lead tungstate crystals as used, for example, in the CMS calorimeter at the CERN LHC.

  1. Characteristics of Cherenkov Radiation in Naturally Occuring Ice

    CERN Document Server

    Mikkelsen, R E; Uggerhøj, U I; Klein, S R

    2016-01-01

    We revisit the theory of Cherenkov radiation in uniaxial crystals. Historically, a number of flawed attempts have been made at explaining this radiation phenomenon and a consistent error-free description is nowhere available. We apply our calculation to a large modern day telescope - IceCube. Being located at the Antarctica, this detector makes use of the naturally occuring ice as a medium to generate Cherenkov radiation. However, due to the high pressure at the depth of the detector site, large volumes of hexagonal ice crystals are formed. We calculate how this affects the Cherenkov radiation yield and angular dependence. We conclude that the effect is small, at most about a percent, and would only be relevant in future high precision instruments like e.g. Precision IceCube Next Generation Upgrade (PINGU). For radio-Cherenkov experiments which use the presence of a clear Cherenkov cone to determine the arrival direction, any variation in emission angle will directly and linearly translate into a change in ap...

  2. Detection of atmospheric Cherenkov radiation using solar heliostat mirrors

    Science.gov (United States)

    Ong, R. A.; Bhattacharya, D.; Covault, C. E.; Dixon, D. D.; Gregorich, D. T.; Hanna, D. S.; Oser, S.; Québert, J.; Smith, D. A.; Tümer, O. T.; Zych, A. D.

    1996-10-01

    There is considerable interest world-wide in developing large area atmospheric Cherenkov detectors for ground-based gamma-ray astronomy. This interest stems, in large part, from the fact that the gamma-ray energy region between 20 and 250 GeV is unexplored by any experiment. Atmospheric Cherenkov detectors offer a possible way to explore this region, but large photon collection areas are needed to achieve low energy thresholds. We are developing an experiment using the heliostat mirrors of a solar power plant as the primary collecting element. As part of this development, we built a detector using four heliostat mirrors, a secondary Fresnel lens, and a fast photon detection system. In November 1994, we used this detector to record atmospheric Cherenkov radiation produced by cosmic ray particles showering in the atmosphere. The detected rate of cosmic ray events was consistent with an energy threshold near 1 TeV. The data presented here represent the first detection of atmospheric Cherenkov radiation using solar heliostats viewed from a central tower.

  3. The High Altitude Water Cherenkov (HAWC) Observatory

    Science.gov (United States)

    Springer, Wayne

    2014-06-01

    The High Altitude Water Cherenkov (HAWC) observatory is a continuously operated, wide field of view detector based upon a water Cherenkov technology developed by the Milagro experiment. HAWC observes, at an elevation of 4100 m on Sierra Negra Mountain in Mexico, extensive air showers initiated by gamma and cosmic rays. The completed detector will consist of 300 closely spaced water tanks each instrumented with four photomultiplier tubes that provide timing and charge information used to reconstruct energy and arrival direction. HAWC has been optimized to observe transient and steady emission from point as well as diffuse sources of gamma rays in the energy range from several hundred GeV to several hundred TeV. Studies in solar physics as well as the properties of cosmic rays will also be performed. HAWC has been making observations at various stages of deployment since completion of 10% of the array in summer 2012. A discussion of the detector design, science capabilities, current construction/commissioning status, and first results will be presented...

  4. Volcanoes muon imaging using Cherenkov telescopes

    Energy Technology Data Exchange (ETDEWEB)

    Catalano, O. [INAF, Istituto di Astrofisica Spaziale e Fisica cosmica di Palermo, via U. La Malfa 153, I-90146 Palermo (Italy); Del Santo, M., E-mail: melania@ifc.inaf.it [INAF, Istituto di Astrofisica Spaziale e Fisica cosmica di Palermo, via U. La Malfa 153, I-90146 Palermo (Italy); Mineo, T.; Cusumano, G.; Maccarone, M.C. [INAF, Istituto di Astrofisica Spaziale e Fisica cosmica di Palermo, via U. La Malfa 153, I-90146 Palermo (Italy); Pareschi, G. [INAF Osservatorio Astronomico di Brera, Via E. Bianchi 46, I-23807, Merate (Italy)

    2016-01-21

    A detailed understanding of a volcano inner structure is one of the key-points for the volcanic hazards evaluation. To this aim, in the last decade, geophysical radiography techniques using cosmic muon particles have been proposed. By measuring the differential attenuation of the muon flux as a function of the amount of rock crossed along different directions, it is possible to determine the density distribution of the interior of a volcano. Up to now, a number of experiments have been based on the detection of the muon tracks crossing hodoscopes, made up of scintillators or nuclear emulsion planes. Using telescopes based on the atmospheric Cherenkov imaging technique, we propose a new approach to study the interior of volcanoes detecting of the Cherenkov light produced by relativistic cosmic-ray muons that survive after crossing the volcano. The Cherenkov light produced along the muon path is imaged as a typical annular pattern containing all the essential information to reconstruct particle direction and energy. Our new approach offers the advantage of a negligible background and an improved spatial resolution. To test the feasibility of our new method, we have carried out simulations with a toy-model based on the geometrical parameters of ASTRI SST-2M, i.e. the imaging atmospheric Cherenkov telescope currently under installation onto the Etna volcano. Comparing the results of our simulations with previous experiments based on particle detectors, we gain at least a factor of 10 in sensitivity. The result of this study shows that we resolve an empty cylinder with a radius of about 100 m located inside a volcano in less than 4 days, which implies a limit on the magma velocity of 5 m/h.

  5. Volcanoes muon imaging using Cherenkov telescopes

    Science.gov (United States)

    Catalano, O.; Del Santo, M.; Mineo, T.; Cusumano, G.; Maccarone, M. C.; Pareschi, G.

    2016-01-01

    A detailed understanding of a volcano inner structure is one of the key-points for the volcanic hazards evaluation. To this aim, in the last decade, geophysical radiography techniques using cosmic muon particles have been proposed. By measuring the differential attenuation of the muon flux as a function of the amount of rock crossed along different directions, it is possible to determine the density distribution of the interior of a volcano. Up to now, a number of experiments have been based on the detection of the muon tracks crossing hodoscopes, made up of scintillators or nuclear emulsion planes. Using telescopes based on the atmospheric Cherenkov imaging technique, we propose a new approach to study the interior of volcanoes detecting of the Cherenkov light produced by relativistic cosmic-ray muons that survive after crossing the volcano. The Cherenkov light produced along the muon path is imaged as a typical annular pattern containing all the essential information to reconstruct particle direction and energy. Our new approach offers the advantage of a negligible background and an improved spatial resolution. To test the feasibility of our new method, we have carried out simulations with a toy-model based on the geometrical parameters of ASTRI SST-2M, i.e. the imaging atmospheric Cherenkov telescope currently under installation onto the Etna volcano. Comparing the results of our simulations with previous experiments based on particle detectors, we gain at least a factor of 10 in sensitivity. The result of this study shows that we resolve an empty cylinder with a radius of about 100 m located inside a volcano in less than 4 days, which implies a limit on the magma velocity of 5 m/h.

  6. The Cherenkov Telescope Array

    Science.gov (United States)

    Connaughton, Valerie

    2014-03-01

    The Cherenkov Telescope Array (CTA) is a large collaborative effort dedicated to the design and operation of the next-generation ground-based very high-energy gamma-ray observatory. CTA will improve by about one order of magnitude the sensitivity with respect to the current major arrays (VERITAS, H.E.S.S., and MAGIC) in the core energy range of 100 GeV to 10 TeV, and will extend the viability of the imaging atmospheric Cherenkov technique (IACT) down to tens of GeV and above 100 TeV. In order to achieve such improved performance at both a northern and southern CTA site, four 23m diameter Large Size Telescopes (LST) optimized for low energy gamma rays will be deployed close to the centre of the array. A larger number of Medium Size Telescopes (MST) will be optimized for the core IACT energy range. The southern site will include 25 12m single-mirror MSTs and a US contribution of up to 24 novel dual-mirror design Schwarzschild-Couder (SC) type MSTs with a primary mirror of 9.5m diameter, and will also include an array of Small Size Telescopes (SST) to observe the highest-energy gamma rays from galactic sources. The SSTs can be smaller and more widely separated because more energetic gamma rays produce a larger Cherenkov light pool with many photons. The SSTs achieve a large collection area by covering a wide (10 sq km) footprint on the ground. The CTA project is finishing its preparatory phase, and the pre-production phase will start this year. I will review the status and the expected performance of CTA as well as the main scientific goals for the observatory.

  7. The Cherenkov Telescope Array

    CERN Document Server

    Bigongiari, Ciro

    2016-01-01

    The Cherenkov Telescope Array (CTA) is planned to be the next generation ground based observatory for very high energy (VHE) gamma-ray astronomy. Gamma-rays provide a powerful insight into the non-thermal universe and hopefully a unique probe for new physics. Imaging Cherenkov telescopes have already discovered more than 170 VHE gamma-ray emitters providing plentiful of valuable data and clearly demonstrating the power of this technique. In spite of the impressive results there are indications that the known sources represent only the tip of the iceberg. A major step in sensitivity is needed to increase the number of detected sources, observe short time-scale variability and improve morphological studies of extended sources. An extended energy coverage is advisable to observe far-away extragalactic objects and improve spectral analysis. CTA aims to increase the sensitivity by an order of magnitude compared to current facilities, to extend the accessible gamma-ray energies from a few tens of GeV to a hundred o...

  8. Separation of Scintillation and Cherenkov Lights in Linear Alkyl Benzene

    CERN Document Server

    Li, Mohan; Yeh, Minfang; Wang, Zhe; Chen, Shaomin

    2015-01-01

    To separate scintillation and Cherenkov lights in water-based liquid scintillator detectors is a desired feature for future neutrino and proton decay researches. Linear alkyl benzene (LAB) is one important ingredient of a water-based liquid scintillator being developed. In this paper we observed a good separation of scintillation and Cherenkov lights in an LAB sample. The rising and decay times of the scintillation light of the LAB were measured to be $(7.7\\pm3.0)\\ \\rm{ns}$ and $(36.6\\pm2.4)\\ \\rm{ns}$, respectively, while the full width [-3$\\sigma$, 3$\\sigma$] of the Cherenkov light was 12 ns dominated by the time resolution of our photomultiplier tubes. The light yield of the scintillation was measured to be $(1.01\\pm0.12)\\times10^3\\ \\rm{photons}/\\rm{MeV}$.

  9. Novel Photo-Detectors and Photo-Detector Systems

    OpenAIRE

    Danilov, M.

    2008-01-01

    Recent developments in photo-detectors and photo-detector systems are reviewed. The main emphasis is made on Silicon Photo-Multipliers (SiPM) - novel and very attractive photo-detectors. Their main features are described. Properties of detectors manufactured by different producers are compared. Different applications are discussed including calorimeters, muon detection, tracking, Cherenkov light detection, and time of flight measurements.

  10. Quenching the scintillation in CF{sub 4} Cherenkov gas radiator

    Energy Technology Data Exchange (ETDEWEB)

    Blake, T. [Department of Physics, University of Warwick, Coventry (United Kingdom); D' Ambrosio, C. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Easo, S. [STFC Rutherford Appleton Laboratory, Didcot (United Kingdom); European Organization for Nuclear Research (CERN), Geneva (Switzerland); Eisenhardt, S. [School of Physics and Astronomy, University of Edinburgh, Edinburgh (United Kingdom); Fitzpatrick, C. [Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne (Switzerland); Forty, R.; Frei, C. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Gibson, V. [Cavendish Laboratory, University of Cambridge, Cambridge (United Kingdom); Gys, T. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Harnew, N.; Hunt, P. [Department of Physics, University of Oxford, Oxford (United Kingdom); Jones, C.R. [Cavendish Laboratory, University of Cambridge, Cambridge (United Kingdom); Lambert, R.W. [Nikhef National Institute for Subatomic Physics and VU University Amsterdam, Amsterdam (Netherlands); Matteuzzi, C. [Sezione INFN di Milano Bicocca, Milano (Italy); Muheim, F. [School of Physics and Astronomy, University of Edinburgh, Edinburgh (United Kingdom); Papanestis, A., E-mail: antonis.papanestis@stfc.ac.uk [STFC Rutherford Appleton Laboratory, Didcot (United Kingdom); European Organization for Nuclear Research (CERN), Geneva (Switzerland); Perego, D.L. [Sezione INFN di Milano Bicocca, Milano (Italy); Università di Milano Bicocca, Milano (Italy); Piedigrossi, D. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Plackett, R. [Imperial College London, London (United Kingdom); Powell, A. [Department of Physics, University of Oxford, Oxford (United Kingdom); and others

    2015-08-11

    CF{sub 4} is used as a Cherenkov gas radiator in one of the Ring Imaging Cherenkov detectors at the LHCb experiment at the CERN Large Hadron Collider. CF{sub 4} is well known to have a high scintillation photon yield in the near and far VUV, UV and in the visible wavelength range. A large flux of scintillation photons in our photon detection acceptance between 200 and 800 nm could compromise the particle identification efficiency. We will show that this scintillation photon emission system can be effectively quenched, consistent with radiationless transitions, with no significant impact on the photons resulting from Cherenkov radiation.

  11. Cherenkov Radiation from $e^+e^-$ Pairs and Its Effect on $\

    CERN Document Server

    Mandal, S K; Jackson, David J; Mandal, Sourav K.; Klein, Spencer R.

    2005-01-01

    We calculate the Cherenkov radiation from an $e^+e^-$ pair at small separations, as occurs shortly after a pair conversion. The radiation is reduced (compared to that from two independent particles) when the pair separation is smaller than the wavelength of the emitted light. We estimate the reduction in light in large electromagnetic showers, and discuss the implications for detectors that observe Cherenkov radiation from showers in the Earth's atmosphere, as well as in oceans and Antarctic ice.

  12. Properties and Performance of Two Wide Field of View Cherenkov/Fluorescence Telescope Array Prototypes

    CERN Document Server

    Zhang, S S; Cao, Z; Chen, S Z; Chen, M J; Chen, Y; Chen, L H; Ding, K Q; He, H H; Liu, J L; Li, X X; Liu, J; Ma, L L; Ma, X H; Sheng, X D; Zhou, B; Zhang, Y; Zhao, J; Zha, M; Xiao, G

    2011-01-01

    A wide field of view Cherenkov/fluorescence telescope array is one of the main components of the Large High Altitude Air Shower Observatory project. To serve as Cherenkov and fluorescence detectors, a flexible and mobile design is adopted for easy reconfiguring of the telescope array. Two prototype telescopes have been constructed and successfully run at the site of the ARGO-YBJ experiment in Tibet. The features and performance of the telescopes are presented.

  13. Fast, Large-Area, Wide-Bandgap UV Photodetector for Cherenkov Light Detection

    Science.gov (United States)

    Wrbanek, John D.; Wrbanek, Susan Y.

    2013-01-01

    Due to limited resources available for power and space for payloads, miniaturizing and integrating instrumentation is a high priority for addressing the challenges of manned and unmanned deep space missions to high Earth orbit (HEO), near Earth objects (NEOs), Lunar and Martian orbits and surfaces, and outer planetary systems, as well as improvements to high-altitude aircraft safety. New, robust, and compact detectors allow future instrumentation packages more options in satisfying specific mission goals. A solid-state ultraviolet (UV) detector was developed with a theoretical fast response time and large detection area intended for application to Cherenkov detectors. The detector is based on the wide-bandgap semiconductor zinc oxide (ZnO), which in a bridge circuit can detect small, fast pulses of UV light like those required for Cherenkov detectors. The goal is to replace the role of photomultiplier tubes in Cherenkov detectors with these solid-state devices, saving on size, weight, and required power. For improving detection geometry, a spherical detector to measure high atomic number and energy (HZE) ions from any direction has been patented as part of a larger space radiation detector system. The detector will require the development of solid-state UV photodetectors fast enough (2 ns response time or better) to detect the shockwave of Cherenkov light emitted as the ions pass through a quartz, sapphire, or acrylic ball. The detector must be small enough to fit in the detector system structure, but have an active area large enough to capture enough Cherenkov light from the sphere. The detector is fabricated on bulk single-crystal undoped ZnO. Inter - digitated finger electrodes and contact pads are patterned via photolithography, and formed by sputtered metal of silver, platinum, or other high-conductivity metal.

  14. Measuring Cherenkov Backgrounds from Proportional Counters in SNO

    Science.gov (United States)

    Seibert, Stanley

    2006-04-01

    In the current phase of operation of the Sudbury Neutrino Observatory, He-3 proportional counters have been deployed in the center of the detector to measure neutron production from neutral-current interactions between neutrinos and deuterons in the heavy water. Radioactive decays of Bi-214 and Tl-208 in the counters produce gammas of sufficient energy to photodisintegrate deuterons, which become a background to the neutral current measurement. We have measured the background rate in-situ using Cherenkov light detected with SNO's 9456 inward-looking photomultiplier tubes. A maximum likelihood method is used to separate backgrounds in the heavy water from backgrounds in the proportional counters based upon the spatial distribution of low energy Cherenkov event vertices. Uncertainties on the backgrounds have been estimated using calibration data taken with both a distributed Na-24 source, and a contained Th source deployed at various points in the detector.

  15. Search for long-lived heavy charged particles using a ring imaging Cherenkov technique at LHCb

    NARCIS (Netherlands)

    Aaij, R.; Adeva, B.; Adinolfi, M.; Affolder, A.; Ajaltouni, Z.; Akar, S.; Albrecht, J.; Alessio, F.; Alexander, M.; Ali, S.; Alkhazov, G.; Cartelle, P. Alvarez; Alves, A. A.; Amato, S.; Amerio, S.; Amhis, Y.; An, L.; Anderlini, L.; Anderson, J.; Andreotti, M.; Andrews, J. E.; Appleby, R. B.; Gutierrez, O. Aquines; Archilli, F.; d'Argent, P.; Artamonov, A.; Artuso, M.; Aslanides, E.; Auriemma, G.; Baalouch, M.; Bachmann, S.; Back, J. J.; Badalov, A.; Baesso, C.; Baldini, W.; Barlow, R. J.; Barschel, C.; Barsuk, S.; Barter, W.; Batozskaya, V.; Battista, V.; Bay, A.; Beaucourt, L.; Beddow, J.; Bedeschi, F.; Bediaga, I.; Bel, L. J.; Belyaev, I.; Ben-Haim, E.; Bencivenni, G.; Benson, S.; Benton, J.; Berezhnoy, A.; Bernet, R.; Bertolin, A.; Bettler, M. -O.; Van Beuzekom, M.; Bien, A.; Bifani, S.; Bird, T.; Birnkraut, A.; Bizzeti, A.; Blake, T.; Blanc, F.; Blouw, J.; Blusk, S.; Bocci, V.; Bondar, A.; Bondar, N.; Bonivento, W.; Borghi, S.; Borgia, A.; Borsato, M.; Bowcock, T. J. V.; Bowen, E.; Bozzi, C.; Brett, D.; Britsch, M.; Britton, T.; Brodzicka, J.; Brook, N. H.; Bursche, A.; Buytaert, J.; Cadeddu, S.; Calabrese, R.; Calvi, M.; Calvo Gomez, M.; Campana, P.; Perez, D. Campora; Capriotti, L.; Carbone, A.; Carboni, G.; Cardinale, R.; Cardini, A.; Carniti, P.; Carson, L.; Carvalho Akiba, K.; Casanova Mohr, R.; Casse, G.; Cassina, L.; Garcia, L. Castillo; Cattaneo, M.; Cauet, Ch.; Cavallero, G.; Cenci, R.; Charles, M.; Charpentier, Ph.; Chefdeville, M.; Chen, S.; Cheung, S. F.; Chiapolini, N.; Chrzaszcz, M.; Vidal, X. Cid; Ciezarek, G.; Clarke, P. E. L.; Clemencic, M.; Cliff, H. V.; Closier, J.; Coco, V.; Cogan, J.; Cogneras, E.; Cogoni, V.; Cojocariu, L.; Collazuol, G.; Collins, P.; Comerma-Montells, A.; Contu, A.; Cook, A.; Coombes, M.; Coquereau, S.; Corti, G.; Corvo, M.; Counts, I.; Couturier, B.; Cowan, G. A.; Craik, D. C.; Crocombe, A.; CruzTorres, M.; Cunliffe, S.; Currie, R.; D'Ambrosio, C.; Dalseno, J.; David, P. N. Y.; Davis, A.; De Bruyn, K.; De Capua, S.; De Cian, M.; De Miranda, J. M.; De Paula, L.; De Silva, W.; De Simone, P.; Dean, C. T.; Decamp, D.; Deckenhoff, M.; Del Buono, L.; Deleage, N.; Derkach, D.; Deschamps, O.; Dettori, F.; Dey, B.; Di Canto, A.; Di Ruscio, F.; Dijkstra, H.; Donleavy, S.; Dordei, F.; Dorigo, M.; Dosil Suarez, A.; Dossett, D.; Dovbnya, A.; Dreimanis, K.; Dujany, G.; Dupertuis, F.; Durante, P.; Dzhelyadin, R.; Dziurda, A.; Dzyuba, A.; Easo, S.; Egede, U.; Egorychev, V.; Eidelman, S.; Eisenhardt, S.; Eitschberger, U.; Ekelhof, R.; Eklund, L.; ElRifai, I.; Elsasser, Ch.; Ely, S.; Esen, S.; Evans, H. M.; Evans, T.; Falabella, A.; Faerber, C.; Farinelli, C.; Farley, N.; Farry, S.; Fay, R.; Ferguson, D.; Fernandez Albor, V.; Ferrari, F.; Ferreira Rodrigues, F.; Ferro-Luzzi, M.; Filippov, S.; Fiore, M.; Fiorini, M.; Firlej, M.; Fitzpatrick, C.; Fiutowski, T.; Fol, P.; Fontana, M.; Fontanelli, F.; Forty, R.; Francisco, O.; Frank, M.; Frei, C.; Frosini, M.; Fu, J.; Furfaro, E.; Torreira, A. Gallas; Galli, D.; Gallorini, S.; Gambetta, S.; Gandelman, M.; Gandini, P.; Gao, Y.; Garcia Pardinas, J.; Garofoli, J.; Tico, J. Garra; Garrido, L.; Gascon, D.; Gaspar, C.; Gauld, R.; Gavardi, L.; Gazzoni, G.; Geraci, A.; Gerick, D.; Gersabeck, E.; Gersabeck, M.; Gershon, T.; Ghez, Ph.; Gianelle, A.; Giani, S.; Gibson, V.; Giubega, L.; Gligorov, V. V.; Goebel, C.; Golubkov, D.; Golutvin, A.; Gomes, A.; Gotti, C.; Gandara, M. Grabalosa; Diaz, R. Graciani; Cardoso, L. A. Granado; Grauges, E.; Graverini, E.; Graziani, G.; Grecu, A.; Greening, E.; Gregson, S.; Griffith, P.; Grillo, L.; Gruenberg, O.; Gui, B.; Gushchin, E.; Guz, Yu.; Gys, T.; Hadjivasiliou, C.; Haefeli, G.; Haen, C.; Haines, S. C.; Hall, S.; Hamilton, B.; Hampson, T.; Han, X.; Hansmann-Menzemer, S.; Harnew, N.; Harnew, S. T.; Harrison, J.; He, J.; Head, T.; Heijne, V.; Hennessy, K.; Henrard, P.; Henry, L.; Hernando Morata, J. A.; van Herwijnen, E.; Hess, M.; Hicheur, A.; Hill, D.; Hoballah, M.; Hombach, C.; Hulsbergen, W.; Humair, T.; Hussain, N.; Hutchcroft, D.; Hynds, D.; Idzik, M.; Ilten, P.; Jacobsson, R.; Jaeger, A.; Jalocha, J.; Jans, E.; Jawahery, A.; Jing, F.; John, M.; Johnson, D.; Jones, C. R.; Joram, C.; Jost, B.; Jurik, N.; Kandybei, S.; Kanso, W.; Karacson, M.; Karbach, T. M.; Karodia, S.; Kelsey, M.; Kenyon, I. R.; Kenzie, M.; Ketel, T.; Khanji, B.; Khurewathanakul, C.; Klaver, S.; Klimaszewski, K.; Kochebina, O.; Kolpin, M.; Komarov, I.; Koopman, R. F.; Koppenburg, P.; Kravchuk, L.; Kreplin, K.; Kreps, M.; Krocker, G.; Krokovny, P.; Kruse, F.; Kucewicz, W.; Kucharczyk, M.; Kudryavtsev, V.; Kurek, K.; Kvaratskheliya, T.; La Thi, V. N.; Lacarrere, D.; Lafferty, G.; Lai, A.; Lambert, D.; Lambert, R. W.; Lanfranchi, G.; Langenbruch, C.; Langhans, B.; Latham, T.; Lazzeroni, C.; Le Gac, R.; van Leerdam, J.; Lees, J. P.; Lefevre, R.; Leflat, A.; Lefrancois, J.; Leroy, O.; Lesiak, T.; Leverington, B.; Li, Y.; Likhomanenko, T.; Liles, M.; Lindner, R.; Linn, C.; Lionetto, F.; Liu, B.; Lohn, S.; Longstaff, I.; Lopes, J. H.; Lucchesi, D.; Luo, H.; Lupato, A.; Luppi, E.; Lupton, O.; Machefert, F.; Machikhiliyan, I. V.; Maciuc, F.; Maev, O.; Malde, S.; Malinin, A.; Manca, G.; Mancinelli, G.; Manning, P.; Mapelli, A.; Maratas, J.; Marchand, J. F.; Marconi, U.; Marin Benito, C.; Marino, P.; Maerki, R.; Marks, J.; Martellotti, G.; Martinelli, M.; Santos, D. Martinez; Martinez Vidal, F.; Martins Tostes, D.; Massafferri, A.; Matev, R.; Mathe, Z.; Matteuzzi, C.; Mauri, A.; Maurin, B.; Mazurov, A.; McCann, M.; McCarthy, J.; Mcnab, A.; McNulty, R.; McSkelly, B.; Meadows, B.; Meier, F.; Meissner, M.; Merk, M.; Milanes, D. A.; Minard, M. N.; Mitzel, D. S.; Molina Rodriguez, J.; Monteil, S.; Morandin, M.; Morawski, P.; Morda, A.; Morello, M. J.; Moron, J.; Morris, A. B.; Mountain, R.; Muheim, F.; Mueller, J.; Mueller, K.; Mueller, V.; Mussini, M.; Muster, B.; Naik, P.; Nakada, T.; Nandakumar, R.; Nasteva, I.; Needham, M.; Neri, N.; Neubert, S.; Neufeld, N.; Neuner, M.; Nguyen, A. D.; Nguyen, T. D.; Nguyen-Mau, C.; Niess, V.; Niet, R.; Nikitin, N.; Nikodem, T.; Novoselov, A.; O'Hanlon, D. P.; Oblakowska-Mucha, A.; Obraztsov, V.; Ogilvy, S.; Okhrimenko, O.; Oldeman, R.; Onderwater, C. J. G.; Osorio Rodrigues, B.; Otalora Goicochea, J. M.; Otto, A.; Owen, P.; Oyanguren, A.; Palano, A.; Palombo, F.; Palutan, M.; Panman, J.; Papanestis, A.; Pappagallo, M.; Pappalardo, L. L.; Parkes, C.; Passaleva, G.; Patel, G. D.; Patel, M.; Patrignani, C.; Pearce, A.; Pellegrino, A.; Penso, G.; Altarelli, M. Pepe; Perazzini, S.; Perret, P.; Pescatore, L.; Petridis, K.; Petrolini, A.; Olloqui, E. Picatoste; Pietrzyk, B.; Pilar, T.; Pinci, D.; Pistone, A.; Playfer, S.; Plo Casasus, M.; Poikela, T.; Polci, F.; Poluektov, A.; Polyakov, I.; Polycarpo, E.; Popov, A.; Popov, D.; Popovici, B.; Potterat, C.; Price, E.; Price, J. D.; Prisciandaro, J.; Pritchard, A.; Prouve, C.; Pugatch, V.; Navarro, A. Puig; Punzi, G.; Qian, W.; Quagliani, R.; Rachwal, B.; Rademacker, J. H.; Rakotomiaramanana, B.; Rama, M.; Rangel, M. S.; Raniuk, I.; Rauschmayr, N.; Raven, G.; Redi, F.; Reichert, S.; Reid, M. M.; dos Reis, A. C.; Ricciardi, S.; Richards, S.; Rihl, M.; Rinnert, K.; Rives Molina, V.; Robbe, P.; Rodrigues, A. B.; Rodrigues, E.; Perez, P. Rodriguez; Roiser, S.; Romanovsky, V.; Romero Vidal, A.; Rotondo, M.; Rouvinet, J.; Ruf, T.; Ruiz, H.; Ruiz Valls, P.; Saborido Silva, J. J.; Sagidova, N.; Sail, P.; Saitta, B.; Salustino Guimaraes, V.; Sanchez Mayordomo, C.; Sanmartin Sedes, B.; Santacesaria, R.; Santamarina Rios, C.; Santovetti, E.; Sarti, A.; Satriano, C.; Satta, A.; Saunders, D. M.; Savrina, D.; Schiller, M.; Schindler, H.; Schlupp, M.; Schmelling, M.; Schmelzer, T.; Schmidt, B.; Schneider, O.; Schopper, A.; Schune, M. H.; Schwemmer, R.; Sciascia, B.; Sciubba, A.; Semennikov, A.; Sepp, I.; Serra, N.; Serrano, J.; Sestini, L.; Seyfert, P.; Shapkin, M.; Shapoval, I.; Shcheglov, Y.; Shears, T.; Shekhtman, L.; Shevchenko, V.; Shires, A.; Coutinho, R. Silva; Simi, G.; Sirendi, M.; Skidmore, N.; Skillicorn, I.; Skwarnicki, T.; Smith, E.; Smith, E.; Smith, J.; Smith, M.; Snoek, H.; Sokoloff, M. D.; Soler, F. J. P.; Soomro, F.; Souza, D.; Souza De Paula, B.; Spaan, B.; Spradlin, P.; Sridharan, S.; Stagni, F.; Stahl, M.; Stahl, S.; Steinkamp, O.; Stenyakin, O.; Sterpka, F.; Stevenson, S.; Stoica, S.; Stone, S.; Storaci, B.; Stracka, S.; Straticiuc, M.; Straumann, U.; Stroili, R.; Sun, L.; Sutcliffe, W.; Swientek, K.; Swientek, S.; Syropoulos, V.; Szczekowski, M.; Szczypka, P.; Szumlak, T.; T'Jampens, S.; Tekampe, T.; Teklishyn, M.; Tellarini, G.; Teubert, F.; Thomas, C.; Thomas, E.; van Tilburg, J.; Tisserand, V.; Tobin, M.; Todd, J.; Tolk, S.; Tomassetti, L.; Tonelli, D.; Topp-Joergensen, S.; Torr, N.; Tournefier, E.; Tourneur, S.; Trabelsi, K.; Tran, M. T.; Tresch, M.; Trisovic, A.; Tsaregorodtsev, A.; Tsopelas, P.; Tuning, N.; Garcia, M. Ubeda; Ukleja, A.; Ustyuzhanin, A.; Uwer, U.; Vacca, C.; Vagnoni, V.; Valenti, G.; Vallier, A.; Gomez, R. Vazquez; Vazquez Regueiro, P.; Vazquez Sierra, C.; Vecchi, S.; Velthuis, J. J.; Veltri, M.; Veneziano, G.; Vesterinen, M.; Viaud, B.; Vieira, D.; Vieites Diaz, M.; Vilasis-Cardona, X.; Vollhardt, A.; Volyanskyy, D.; Voong, D.; Vorobyev, A.; Vorobyev, V.; Voss, C.; de Vries, J. A.; Waldi, R.; Wallace, C.; Wallace, R.; Walsh, J.; Wandernoth, S.; Wang, J.; Ward, D. R.; Watson, N. K.; Websdale, D.; Weiden, A.; Whitehead, M.; Wiedner, D.; Wilkinson, G.; Wilkinson, M.; Williams, M.; Williams, M. P.; Williams, M.; Wilson, F. F.; Wimberley, J.; Wishahi, J.; Wislicki, W.; Witek, M.; Wormser, G.; Wotton, S. A.; Wright, S.; Wyllie, K.; Xie, Y.; Xu, Z.; Yang, Z.; Yuan, X.; Yushchenko, O.; Zangoli, M.; Zavertyaev, M.; Zhang, L.; Zhang, Y.; Zhelezov, A.; Zhokhov, A.; Zhong, L.

    2015-01-01

    A search is performed for heavy long-lived charged particles using 3.0 fb(-1) of proton-proton collisions collected at root s = 7 and 8 TeV with the LHCb detector. The search is mainly based on the response of the ring imaging Cherenkov detectors to distinguish the heavy, slow-moving particles from

  16. The High-Altitude Water Cherenkov Observatory

    Science.gov (United States)

    Mostafá, Miguel A.

    2014-10-01

    The High-Altitude Water Cherenkov (HAWC) observatory is a large field of view, continuously operated, TeV γ-ray experiment under construction at 4,100 m a.s.l. in Mexico. The HAWC observatory will have an order of magnitude better sensitivity, angular resolution, and background rejection than its predecessor, the Milagro experiment. The improved performance will allow us to detect both the transient and steady emissions, to study the Galactic diffuse emission at TeV energies, and to measure or constrain the TeV spectra of GeV γ-ray sources. In addition, HAWC will be the only ground-based instrument capable of detecting prompt emission from γ-ray bursts above 50 GeV. The HAWC observatory will consist of an array of 300 water Cherenkov detectors (WCDs), each with four photomultiplier tubes. This array is currently under construction on the flanks of the Sierra Negra volcano near the city of Puebla, Mexico. The first 30 WCDs (forming an array approximately the size of Milagro) were deployed in Summer 2012, and 100 WCDs will be taking data by May, 2013. We present in this paper the motivation for constructing the HAWC observatory, the status of the deployment, and the first results from the constantly growing array.

  17. The high-altitude water Cherenkov Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Mostafa, Miguel A., E-mail: miguel@psu.edu [Department of Physics, Colorado State University, Ft Collins, CO (United States)

    2014-07-01

    The High-Altitude Water Cherenkov (HAWC) observatory is a large field of view, continuously operated, TeV γ -ray experiment under construction at 4,100ma.s.l. in Mexico. The HAWC observatory will have an order of magnitude better sensitivity, angular resolution, and background rejection than its predecessor, the Milagro experiment. The improved performance will allow to detect both the transient and steady emissions, to study the Galactic diffuse emission at TeV energies, and to measure or constrain the TeV spectra of GeV γ -ray sources. In addition, HAWC will be the only ground-based instrument capable of detecting prompt emission from γ -ray bursts above 50 GeV. The HAWC observatory will consist of an array of 300 water Cherenkov detectors (WCDs), each with four photomultiplier tubes. This array is currently under construction on the flanks of the Sierra Negra volcano near the city of Puebla, Mexico. The first 30 WCDs (forming an array approximately the size of Milagro) were deployed in Summer 2012, and 100 WCDs will be taking data by May, 2013. We present in this paper the motivation for constructing the HAWC observatory, the status of the deployment, and the first results from the constantly growing array. (author)

  18. The High Altitude Water Cherenkov Observatory

    Science.gov (United States)

    Mostafa, Miguel; HAWC Collaboration

    2016-03-01

    The High Altitude Water Cherenkov (HAWC) Observatory is a continuously operated, wide field of view experiment comprised of an array of 300 water Cherenkov detectors (WCDs) to study transient and steady emission of TeV gamma and cosmic rays. Each 200000 l WCD is instrumented with 4 PMTs providing charge and timing information. The array covers ~22000 m2 at an altitude of 4100 m a.s.l. inside the Pico de Orizaba national park in Mexico. The high altitude, large active area, and optical isolation of the PMTs allows us to reliably estimate the energy and determine the arrival direction of gamma and cosmic rays with significant sensitivity over energies from several hundred GeV to a hundred TeV. Continuously observing 2 / 3 of the sky every 24 h, HAWC plays a significant role as a survey instrument for multi-wavelength studies. The performance of HAWC makes possible the detection of both transient and steady emissions, the study of diffuse emission and the measurement of the spectra of gamma-ray sources at TeV energies. HAWC is also sensitive to the emission from GRBs above 100 GeV. I will highlight the results from the first year of operation of the full HAWC array, and describe the ongoing site work to expand the array by a factor of 4 to explore the high energy range.

  19. The High Altitude Water Cherenkov Observatory

    CERN Document Server

    ,

    2013-01-01

    The High Altitude Water Cherenkov (HAWC) observatory is a large field of view, continuously operated, TeV gamma-ray experiment under construction at 4,100 m a.s.l. in Mexico. The HAWC observatory will have an order of magnitude better sensitivity, angular resolution, and background rejection than its predecessor, the Milagro experiment. The improved performance will allow us to detect both transient and steady emissions, to study the Galactic diffuse emission at TeV energies, and to measure or constrain the TeV spectra of GeV gamma-ray sources. In addition, HAWC will be the only ground-based instrument capable of detecting prompt emission from gamma-ray bursts above 50 GeV. The HAWC observatory will consist of an array of 300 water Cherenkov detectors (WCDs), each with four photomultiplier tubes. This array is currently under construction on the flanks of the Sierra Negra volcano near the city of Puebla, Mexico. The first thirty WCDs (forming an array approximately the size of Milagro) were deployed in Summer...

  20. Cherenkov luminescence measurements with digital silicon photomultipliers: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Ciarrocchi, Esther; Belcari, Nicola; Guerra, Alberto Del [Department of Physics, University of Pisa, Pisa (Italy); INFN, section of Pisa, Pisa (Italy); Cherry, Simon R. [Department of Biomedical Engineering, University of California, Davis, CA (United States); Lehnert, Adrienne; Hunter, William C. J.; McDougald, Wendy; Miyaoka, Robert S.; Kinahan, Paul E. [Department of Radiology, University of Washington, Seattle, WA (United States)

    2015-11-16

    A feasibility study was done to assess the capability of digital silicon photomultipliers to measure the Cherenkov luminescence emitted by a β source. Cherenkov luminescence imaging (CLI) is possible with a charge coupled device (CCD) based technology, but a stand-alone technique for quantitative activity measurements based on Cherenkov luminescence has not yet been developed. Silicon photomultipliers (SiPMs) are photon counting devices with a fast impulse response and can potentially be used to quantify β-emitting radiotracer distributions by CLI. In this study, a Philips digital photon counting (PDPC) silicon photomultiplier detector was evaluated for measuring Cherenkov luminescence. The PDPC detector is a matrix of avalanche photodiodes, which were read one at a time in a dark count map (DCM) measurement mode (much like a CCD). This reduces the device active area but allows the information from a single avalanche photodiode to be preserved, which is not possible with analog SiPMs. An algorithm to reject the noisiest photodiodes and to correct the measured count rate for the dark current was developed. The results show that, in DCM mode and at (10–13) °C, the PDPC has a dynamic response to different levels of Cherenkov luminescence emitted by a β source and transmitted through an opaque medium. This suggests the potential for this approach to provide quantitative activity measurements. Interestingly, the potential use of the PDPC in DCM mode for direct imaging of Cherenkov luminescence, as a opposed to a scalar measurement device, was also apparent. We showed that a PDPC tile in DCM mode is able to detect and image a β source through its Cherenkov radiation emission. The detector’s dynamic response to different levels of radiation suggests its potential quantitative capabilities, and the DCM mode allows imaging with a better spatial resolution than the conventional event-triggered mode. Finally, the same acquisition procedure and data processing could

  1. Development of a diagnostic technique based on Cherenkov effect for measurements of fast electrons in fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Plyusnin, V. V.; Duarte, P.; Fernandes, H.; Silva, C. [Association Euratom/IST, Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Universidade Tecnica de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa (Portugal); Jakubowski, L.; Zebrowski, J.; Malinowski, K.; Rabinski, M.; Sadowski, M. J. [National Centre for Nuclear Research (NCBJ), 7 Andrzeja Soltana Str., 05-400 Otwock (Poland)

    2012-08-15

    A diagnostic technique based on the Cherenkov effect is proposed for detection and characterization of fast (super-thermal and runaway) electrons in fusion devices. The detectors of Cherenkov radiation have been specially designed for measurements in the ISTTOK tokamak. Properties of several materials have been studied to determine the most appropriate one to be used as a radiator of Cherenkov emission in the detector. This technique has enabled the detection of energetic electrons (70 keV and higher) and the determination of their spatial and temporal variations in the ISTTOK discharges. Measurement of hard x-ray emission has also been carried out in experiments for validation of the measuring capabilities of the Cherenkov-type detector and a high correlation was found between the data of both diagnostics. A reasonable agreement was found between experimental data and the results of numerical modeling of the runaway electron generation in ISTTOK.

  2. Design optimization of the proximity focusing RICH with dual aerogel radiator using a maximum-likelihood analysis of Cherenkov rings

    Science.gov (United States)

    Pestotnik, R.; Križan, P.; Korpar, S.; Iijima, T.

    2008-09-01

    The use of a sequence of aerogel radiators with different refractive indices in a proximity focusing Cherenkov ring imaging detector has been shown to improve the resolution of the Cherenkov angle. In order to obtain further information on the capabilities of such a detector, a maximum-likelihood analysis has been performed on simulated data, with the simulation being appropriate for the upgraded Belle detector. The results show that by using a sequence of two aerogel layers with different refractive indices, the K/π separation efficiency is improved in the kinematic region above 3 GeV/ c. In the low momentum region, the focusing configuration (with n1 and n2 chosen such that the Cherenkov rings from different aerogel layers at 4 GeV/ c overlap) shows a better performance than the defocusing one (where the two Cherenkov rings are well separated).

  3. Results on the Performance of a Broad Band Focussing Cherenkov Counter

    Science.gov (United States)

    Cester, R.; Fitch, V. L.; Montag, A.; Sherman, S.; Webb, R. C.; Witherell, M. S.

    1980-01-01

    The field of ring imaging (broad band differential) Cherenkov detectors has become a very active area of interest in detector development at several high energy physics laboratories. Our group has previously reported on a method of Cherenkov ring imaging for a counter with large momentum and angular acceptance using standard photo multipliers. Recently, we have applied this technique to the design of a set of Cherenkov counters for use in a particle search experiment at Fermi National Accelerator Laboratory (FNAL). This new detector operates over the range 0.998 a delta..beta.. approx. 2 x 10{sup -4}. The acceptance in angle is +- 14 mrad in the horizontal and +- 28 mrad in the vertical. We report here on the performance of this counter.

  4. Cherenkov radiation oscillator without reflectors

    Science.gov (United States)

    Li, D.; Wang, Y.; Hangyo, M.; Wei, Y.; Yang, Z.; Miyamoto, S.

    2014-05-01

    This Letter presents a Cherenkov radiation oscillator with an electron beam travelling over a finitely thick plate made of negative-index materials. In such a scheme, the external reflectors required in the traditional Cherenkov oscillators are not necessary, since the electromagnetic energy flows backward in the negative-index materials, leading to inherent feedback. We theoretically analyzed the interaction between the electron beam and the electromagnetic wave, and worked out the growth rate and start current through numerical calculations. With the help of particle-in-cell simulation, the theoretical predictions are well demonstrated.

  5. The STACEE-32 Ground Based Gamma-ray Detector

    CERN Document Server

    Hanna, D S; Boone, L M; Chantell, M C; Conner, Z; Covault, C E; Dragovan, M; Fortin, P; Gregorich, D T; Hinton, J A; Mukherjee, R; Ong, R A; Oser, S; Ragan, K; Scalzo, R A; Schütte, D R; Theoret, C G; Tümer, T O; Williams, D A; Zweerink, J A

    2002-01-01

    We describe the design and performance of the Solar Tower Atmospheric Cherenkov Effect Experiment detector in its initial configuration (STACEE-32). STACEE is a new ground-based gamma ray detector using the atmospheric Cherenkov technique. In STACEE, the heliostats of a solar energy research array are used to collect and focus the Cherenkov photons produced in gamma-ray induced air showers. The large Cherenkov photon collection area of STACEE results in a gamma-ray energy threshold below that of previous detectors.

  6. Operational performance of the Hall A mirror aerogel Cherenkov counter

    CERN Document Server

    Brash, E J; Lolos, G J; Huber, G M; Meer, R V D; Papandreou, Z

    2002-01-01

    We report the results of an operational test of the efficiency and position sensitivity of a silica-aerogel Cherenkov detector installed in the HRS-E spectrometer in Hall A at Jefferson Lab. The calibration was performed with data from elastic electron scattering from polarized sup 3 He. The response of the photo-multiplier tubes was linearized with a quadratic correction, allowing a unique number of photo-electrons (PEs) to be extracted. The result obtained (approx 7.3 PEs) is consistent with the performance of the prototype detector tested earlier under ideal conditions.

  7. The Non-Imaging CHErenkov (NICHE) Array: A TA/TALE extension using Cherenkov radiation to measure Cosmic Ray Composition to sub-PeV energies

    Science.gov (United States)

    Krizmanic, John; Bergman, Douglas; Tsunesada, Yoshiki; Abu-Zayyad, Tareq; Belz, John; Thomson, Gordon

    2017-01-01

    Co-sited with the Telescope Array (TA) Low Energy (TALE) extension, the Non-Imaging CHErenkov (NICHE) Array will measure the flux and nuclear composition evolution of cosmic rays (CRs) from below 1 PeV to 1 EeV in its eventual full deployment. NICHE will co-measure CR air showers with TA/TALE and will initially be deployed to observe events simultaneously with the TALE telescopes acting in imaging-Cherenkov mode, providing the first hybrid-Cherenkov (simultaneous imaging and non-imaging Cherenkov) measurements of CRs in the Knee region of the CR energy spectrum. NICHE uses easily deployable detectors to measure the amplitude and time-spread of the air-shower Cherenkov signal to achieve an event-by-event measurement of Xmax and energy, each with excellent resolution. First generation detectors are under construction and will form an initial prototype array (jNICHE) that will be deployed in early 2017 at the TA/TALE site. In this talk, the NICHE design, array performance, jNICHE development, and status will be discussed as well as NICHE's ability to measure the cosmic ray nuclear composition as a function of energy.

  8. FACT -- Operation of the First G-APD Cherenkov Telescope

    CERN Document Server

    Bretz, T; Buß, J; Commichau, V; Djambazov, L; Dorner, D; Einecke, S; Eisenacher, D; Freiwald, J; Grimm, O; von Gunten, H; Haller, C; Hempfling, C; Hildebrand, D; Hughes, G; Horisberger, U; Knoetig, M L; Krähenbühl, T; Lustermann, W; Lyard, E; Mannheim, K; Meier, K; Mueller, S; Neise, D; Overkemping, A -K; Paravac, A; Pauss, F; Rhode, W; Röser, U; Stucki, J -P; Steinbring, T; Temme, F; Thaele, J; Vogler, P; Walter, R; Weitzel, Q

    2014-01-01

    Since more than two years, the First G-APD Cherenkov Telescope (FACT) is operating successfully at the Canary Island of La Palma. Apart from its purpose to serve as a monitoring facility for the brightest TeV blazars, it was built as a major step to establish solid state photon counters as detectors in Cherenkov astronomy. The camera of the First G-APD Cherenkov Telesope comprises 1440 Geiger-mode avalanche photo diodes (G-APD aka. MPPC or SiPM) for photon detection. Since properties as the gain of G-APDs depend on temperature and the applied voltage, a real-time feedback system has been developed and implemented. To correct for the change introduced by temperature, several sensors have been placed close to the photon detectors. Their read out is used to calculate a corresponding voltage offset. In addition to temperature changes, changing current introduces a voltage drop in the supporting resistor network. To correct changes in the voltage drop introduced by varying photon flux from the night-sky background...

  9. Results and prospects on registration of reflected Cherenkov light of EAS from cosmic particles above 10^{15} eV

    CERN Document Server

    Antonov, R A; Bonvech, E A; Chernov, D V; Dzhatdoev, T A; Finger, Mich; Finger, Mir; Galkin, V I; Podgrudkov, D A; Roganova, T M

    2015-01-01

    We give an overview of the SPHERE experiment based on detection of reflected Vavilov-Cherenkov radiation (Cherenkov light) from extensive air showers in the energy region E>10^{15} eV. A brief history of the reflected Cherenkov light technique is given; the observations carried out with the SPHERE-2 detector are summarized; the methods of the experimental datasample analysis are described. The first results on the primary cosmic ray all-nuclei energy spectrum and mass composition are presented. Finally, the prospects of the SPHERE experiment and the reflected Cherenkov light technique are given.

  10. Schwarzschild-Couder Telescope for the Cherenkov Telescope Array

    CERN Document Server

    Meagher, Kevin J

    2014-01-01

    The Cherenkov Telescope Array (CTA) is the next major ground-based observatory for gamma-ray astronomy. With CTA gamma-ray sources will be studied in the very-high energy gamma-ray range of a few tens of GeV to 100 TeV with up to ten times better sensitivity than available with current generation instruments. We discuss the proposed US contribution to CTA that comprises imaging atmospheric Cherenkov telescope with Schwarzschild-Couder (SC) optics. Key features of the SC telescope are a wide field of view of eight degrees, a finely pixelated camera with silicon photomultipliers as photon detectors, and a compact and power efficient 1 GS/s readout. The progress in both the optical system and camera development are discussed in this paper.

  11. Detection of Cherenkov light emission in liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Antonello, M.; Arneodo, F.; Badertscher, A.; Baiboussinov, B.; Baldo Ceolin, M.; Battistoni, G.; Bekman, B.; Benetti, P.; Bernardini, E.; Bischofberger, M.; Borio di Tigliole, A.; Brunetti, R.; Bueno, A.; Calligarich, E.; Campanelli, M.; Carpanese, C.; Cavalli, D.; Cavanna, F. E-mail: flavio.cavanna@aquila.infn.it; Cennini, P.; Centro, S.; Cesana, A.; Chen, C.; Chen, D.; Chen, D.B.; Chen, Y.; Cieslik, C.; Cline, D.; Dai, Z.; De Vecchi, C.; Dabrowska, A.; Dolfini, R.; Felcini, M.; Ferrari, A.; Ferri, F.; Ge, Y.; Gibin, D.; Gigli Berzolari, A.; Gil-Botella, I.; Graczyk, K.; Grandi, L.; Guglielmi, A.; He, K.; Holeczek, J.; Huang, X.; Juszczak, C.; Kielczewska, D.; Kisiel, J.; Kozlowski, T.; Laffranchi, M.; Lagoda, J.; Li, Z.; Lu, F.; Ma, J.; Markiewicz, M.; Matthey, C.; Mauri, F.; Mazza, D.; Meng, G.; Messina, M.; Montanari, C.; Muraro, S.; Navas-Concha, S.; Nurzia, G.; Otwinowski, S.; Ouyang, Q.; Palamara, O.; Pascoli, D.; Periale, L.; Piano Mortari, G.B.; Piazzoli, A.; Picchi, P.; Pietropaolo, F.; Polchlopek, W.; Rancati, T.; Rappoldi, A.; Raselli, G.L.; Rico, J.; Rondio, E.; Rossella, M.; Rubbia, A.; Rubbia, C.; Sala, P.; Scannicchio, D.; Segreto, E.; Seo, Y.; Sergiampietri, F.; Sobczyk, J.; Stepaniak, J.; Szarska, M.; Szeptycka, M.; Terrani, M.; Ventura, S.; Vignoli, C.; Wang, H.; Woo, J.; Xu, G.; Xu, Z.; Zalewska, A.; Zalipska, J.; Zhang, C.; Zhang, Q.; Zhen, S.; Zipper, W

    2004-01-11

    Detection of Cherenkov light emission in liquid argon has been obtained with an ICARUS prototype, during a dedicated test run at the Gran Sasso Laboratory external facility. Ionizing tracks from cosmic ray muons crossing the detector active volume have been collected in coincidence with visible light signals from a photo-multiplier (PMT) immersed in liquid argon. A 3D reconstruction of the tracks has been performed exploiting the ICARUS imaging capability. The angular distributions of the tracks triggered by the PMT signals show an evident directionality. By means of a detailed Monte Carlo simulation we show that the geometrical characteristics of the events are compatible with the hypothesis of Cherenkov light emission as the main source of the PMT signals.

  12. Developments on RICH detectors; Les developpements sur les detecteurs RICH

    Energy Technology Data Exchange (ETDEWEB)

    Besson, P.; Bourgeois, P. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. d`Astrophysique, de la Physique des Particules, de la Physique Nucleaire et de l`Instrumentation Associee

    1996-12-31

    The RICH (ring imaging Cherenkov) detector which is dedicated to Cherenkov radiation detection is described. An improvement made by replacing photo sensible vapor with solid photocathode is studied. A RICH detector prototype with a CsI photocathode has been built in Saclay and used with Saturne. The first results are presented. (A.C.) 13 refs.

  13. First studies of 500-nm Cherenkov radiation from 255-MeV electrons in a diamond crystal

    Energy Technology Data Exchange (ETDEWEB)

    Takabayashi, Y., E-mail: takabayashi@saga-ls.jp [SAGA Light Source, 8-7 Yayoigaoka, Tosu, Saga 841-0005 (Japan); Fiks, E.I. [National Research Tomsk Polytechnic University, 634050 Tomsk (Russian Federation); Pivovarov, Yu.L. [National Research Tomsk Polytechnic University, 634050 Tomsk (Russian Federation); National Research Tomsk State University, 634050 Tomsk (Russian Federation)

    2015-06-12

    The first experiment on Cherenkov light from 255-MeV electrons passing through a 50-μm-thick diamond crystal in a special geometry allowing extraction of 500-nm Cherenkov light at a right angle with respect to the electron beam direction has been performed at the injector linac of SAGA Light Source accelerator facility. The dependence of 500-nm Cherenkov light intensity (separated by a band-pass filter) on the crystal rotation angle was measured by a CCD detector. The experimentally obtained rocking curve with an intense maximum is theoretically explained as the projector effect of Cherenkov light deflected by the exit surface of the crystal. The width of the rocking curve is explained by the convolution of the standard Tamm–Frank angular distribution of Cherenkov radiation with chromatic aberration, the multiple scattering of electrons in a crystal, and initial electron beam angular divergence. In addition, it is found that the Cherenkov light intensity did not change under the (220) planar channeling condition, which is consistent with a recent theory. - Highlights: • Cherenkov light from 255-MeV electrons in a diamond crystal has been investigated. • The Cherenkov light from channeled electrons has been observed for the first time. • The experimental results are in good agreement with theory.

  14. The Physics and Nuclear Nonproliferation Goals of WATCHMAN: A WAter CHerenkov Monitor for ANtineutrinos

    CERN Document Server

    Askins, M; Bernstein, A; Dazeley, S; Dye, S T; Handler, T; Hatzikoutelis, A; Hellfeld, D; Jaffke, P; Kamyshkov, Y; Land, B J; Learned, J G; Marleau, P; Mauger, C; Gann, G D Orebi; Roecker, C; Rountree, S D; Shokair, T M; Smy, M B; Svoboda, R; Sweany, M; Vagins, M R; van Bibber, K A; Vogelaar, R B; Wetstein, M J; Yeh, M

    2015-01-01

    This article describes the physics and nonproliferation goals of WATCHMAN, the WAter Cherenkov Monitor for ANtineutrinos. The baseline WATCHMAN design is a kiloton scale gadolinium-doped (Gd) light water Cherenkov detector, placed 13 kilometers from a civil nuclear reactor in the United States. In its first deployment phase, WATCHMAN will be used to remotely detect a change in the operational status of the reactor, providing a first- ever demonstration of the potential of large Gd-doped water detectors for remote reactor monitoring for future international nuclear nonproliferation applications. During its first phase, the detector will provide a critical large-scale test of the ability to tag neutrons and thus distinguish low energy electron neutrinos and antineutrinos. This would make WATCHMAN the only detector capable of providing both direction and flavor identification of supernova neutrinos. It would also be the third largest supernova detector, and the largest underground in the western hemisphere. In a...

  15. Influence of aerosols from biomass burning on the spectral analysis of Cherenkov telescopes

    CERN Document Server

    Reyes, R de los; Bernloehr, K; Krueger, P; Deil, C; Gast, H; Kosack, K; Marandon, V

    2013-01-01

    During the last decade, imaging atmospheric Cherenkov telescopes (IACTs) have proven themselves as astronomical detectors in the very-high-energy (VHE; E>0.1 TeV) regime. The IACT technique observes the VHE photons indirectly, using the Earth's atmosphere as a calorimeter. Much of the calibration of Cherenkov telescope experiments is done using Monte Carlo simulations of the air shower development, Cherenkov radiation and detector, assuming certain models for the atmospheric conditions. Any deviation of the real conditions during observations from the assumed atmospheric model will result in a wrong reconstruction of the primary gamma-ray energy and the resulting source spectra. During eight years of observations, the High Energy Stereoscopic System (H.E.S.S.) has experienced periodic natural as well as anthropogenic variations of the atmospheric transparency due to aerosols created by biomass burning. In order to identify data that have been taken under such long-term reductions in atmospheric transparency, ...

  16. Cherenkov particle identification in FOCUS

    CERN Document Server

    Link, J M; Alimonti, G; Anjos, J C; Arena, V; Bediaga, I; Bianco, S; Boca, G; Bonomi, G; Boschini, M; Butler, J N; Carrillo, S; Casimiro, E; Cawlfield, C; Cheung, H W K; Cho, K; Chung, Y S; Cinquini, L; Cuautle, E; Cumalat, J P; D'Angelo, P; Di Corato, M; Dini, P; Engh, D; Fabbri, Franco Luigi; Gaines, I; Garbincius, P H; Gardner, R; Garren, L A; Giammarchi, M; Gianini, G; Gottschalk, E; Göbel, C; Handler, T; Hernández, H; Hosack, M; Inzani, P; Johns, W E; Kang, J S; Kasper, P H; Kim, D Y; Ko, B R; Kreymer, A E; Kryemadhi, A; Kutschke, R; Kwak, J W; Lee, K B; Leveraro, F; Liguori, G; Magnin, J; Malvezzi, S; Massafferri, A; Menasce, D; Merlo, M M; Mezzadri, M; Milazzo, L; Miranda, J M D; Mitchell, R; Montiel, E; Moroni, L; Méndez, H; Méndez, L; Nehring, M S; O'Reilly, B; Olaya, D; Pantea, D; Paris, A; Park, H; Park, K S; Pedrini, D; Pepe, I M; Pontoglio, C; Prelz, F; Quinones, J; Rahimi, A; Ramírez, J E; Ratti, S P; Reis, A C D; Reyes, M; Riccardi, C; Rivera, C; Rovere, M; Sala, S; Sarwar, S; Segoni, I; Sheaff, M; Sheldon, P D; Stenson, K; Sánchez-Hernández, A; Uribe, C; Vaandering, E W; Vitulo, P; Vázquez, F; Webster, M; Wilson, J R; Wiss, J; Xiong, W; Yager, P M; Zallo, A; Zhang, Y

    2002-01-01

    We describe the algorithm used to identify charged tracks in the fixed-target charm-photoproduction experiment FOCUS. We begin by describing the new algorithm and contrast this approach with that used in our preceding experiment - E687. We next illustrate the algorithm's performance using physics signals. Finally, we briefly describe some of the methods used to monitor the quantum efficiency and noise of the Cherenkov cells.

  17. Cherenkov particle identification in FOCUS

    Energy Technology Data Exchange (ETDEWEB)

    Link, J.M.; Reyes, M.; Yager, P.M.; Anjos, J.C.; Bediaga, I.; Goebel, C.; Magnin, J.; Massafferri, A.; Miranda, J.M. de; Pepe, I.M.; Reis, A.C. dos; Carrillo, S.; Casimiro, E.; Cuautle, E.; Sanchez-Hernandez, A.; Uribe, C.; Vazquez, F.; Cinquini, L.; Cumalat, J.P.; O' Reilly, B.; Ramirez, J.E.; Vaandering, E.W.; Butler, J.N.; Cheung, H.W.K.; Gaines, I.; Garbincius, P.H.; Garren, L.A.; Gottschalk, E.; Kasper, P.H.; Kreymer, A.E.; Kutschke, R.; Bianco, S.; Fabbri, F.L.; Sarwar, S.; Zallo, A.; Cawlfield, C.; Kim, D.Y.; Park, K.S.; Rahimi, A.; Wiss, J. E-mail: jew@uiuc.edu; Gardner, R.; Kryemadhi, A.; Chung, Y.S.; Kang, J.S.; Ko, B.R.; Kwak, J.W.; Lee, K.B.; Park, H.; Alimonti, G.; Boschini, M.; D' Angelo, P.; DiCorato, M.; Dini, P.; Giammarchi, M.; Inzani, P.; Leveraro, F.; Malvezzi, S.; Menasce, D.; Mezzadri, M.; Milazzo, L.; Moroni, L.; Pedrini, D.; Pontoglio, C.; Prelz, F.; Rovere, M.; Sala, S.; Davenport III, T.F.; Agostino, L.; Arena, V.; Boca, G.; Bonomi, G.; Gianini, G.; Liguori, G.; Merlo, M.M.; Pantea, D.; Ratti, S.P.; Riccardi, C.; Segoni, I.; Vitulo, P.; Hernandez, H.; Lopez, A.M.; Mendez, H.; Mendez, L.; Montiel, E.; Olaya, D.; Paris, A.; Quinones, J.; Rivera, C.; Xiong, W.; Zhang, Y.; Wilson, J.R.; Cho, K.; Handler, T.; Mitchell, R.; Engh, D.; Johns, W.E.; Hosack, M.; Nehring, M.S.; Sheldon, P.D.; Stenson, K.; Webster, M.S.; Sheaff, M

    2002-05-21

    We describe the algorithm used to identify charged tracks in the fixed-target charm-photoproduction experiment FOCUS. We begin by describing the new algorithm and contrast this approach with that used in our preceding experiment - E687. We next illustrate the algorithm's performance using physics signals. Finally, we briefly describe some of the methods used to monitor the quantum efficiency and noise of the Cherenkov cells.

  18. Cherenkov radiation threshold in random inhomogeneous media

    CERN Document Server

    Grichine, V M

    2009-01-01

    Cherenkov radiation in media with random inhomogeneities like aerogel or Earth atmosphere is discussed. The spectral-angular distribution of Cherenkov photons emitted by relativistic charged particle and averaged over the dielectric permittivity fluctuations shows angular broadening similarly to the case of media with the photon absorption. The broadening results in the smoothing of Cherenkov threshold, and therefore media with strong photon scattering have more extended dependence of Cherenkov light output on the particle speed. It can be potentially used for the particle identification

  19. Development of a SiPM Cherenkov camera demonstrator for the CTA observatory telescopes

    OpenAIRE

    Ambrosio, Michelangelo; Ambrosi, Giovanni; Aramo, Carla; Bissaldi, Elisabetta; Boiano, Alfonso; Bonavolontà, Carmela; Fiandrini, Emanuele; Giglietto, Nicola; Giordano, Francesco; Ionica, Maria; de Lisio, Corrado; Masone, Vincenzo; Paoletti, Riccardo; Postolache, Vasile; Rugliancich, Andrea

    2016-01-01

    The Cherenkov Telescope Array (CTA) Consortium is developing the new generation of ground observatories for the detection of ultra-high energy gamma-rays. The Italian Institute of Nuclear Physics (INFN) is participating to the R&D of a possible solution for the Cherenkov photon cameras based on Silicon Photomultiplier (SiPM) detectors sensitive to Near Ultraviolet (NUV) energies. The latest NUV-HD SiPM technology achieved by the collaboration of INFN with Fondazione Bruno Kessler (FBK) is bas...

  20. Recent AGN Observations by the Solar Tower Atmospheric Cherenkov Effect Experiment

    Science.gov (United States)

    Kildea, J.; Alabiso, A.; Bramel, D. A.; Carson, J.; Covault, C. E.; Driscoll, D.; Fortin, P.; Gingrich, D. M.; Hanna, D. S.; Jarvis, A.; Lindner, T.; Mukherjee, R.; Mueller, C.; Ong, R. A.; Ragan, K.; Scalzo, R. A.; Williams, D. A.; Zweerink, J.

    2005-02-01

    The Solar Tower Atmospheric Cherenkov Effect Experiment (STACEE) is a ground-based atmospheric Cherenkov telescope for the detection of very high energy gamma rays from Galactic and extra-galactic sources. By utilizing the large collection area provided by the solar mirrors of the National Solar Thermal Test Facility in Albuquerque, New Mexico, STACEE achieves a low energy threshold, around 100 GeV, for the detection of gamma rays. We briefly describe the STACEE detector and detail recent observations of Active Galactic Nuclei.

  1. Sensivity studies for the Cherenkov Telescope Array

    Science.gov (United States)

    Collado, Tarek Hassan

    2015-06-01

    Since the creation of the first telescope in the 17th century, every major discovery in astrophysics has been the direct consequence of the development of novel observation techniques, opening new windows in the electromagnetic spectrum. After Karl Jansky discovered serendipitously the first radio source in 1933, Grote Reber built the first parabolic radio telescope in his backyard, planting the seed of a whole new field in astronomy. Similarly, new technologies in the 1950s allowed the establishment of other fields, such as the infrared, ultraviolet or the X-rays. The highest energy end of the electromagnetic spectrum, the γ-ray range, represents the last unexplored window for astronomers and should reveal the most extreme phenomena that take place in the Universe. Given the technical complexity of γ-ray detection and the extremely relative low fluxes, γ-ray astronomy has undergone a slower development compared to other wavelengths. Nowadays, the great success of consecutive space missions together with the development and refinement of new detection techniques from the ground, has allowed outstanding scientific results and has brought gamma-ray astronomy to a worthy level in par with other astronomy fields. This work is devoted to the study and improvement of the future Cherenkov Telescope Array (CTA), the next generation of ground based γ-ray detectors, designed to observe photons with the highest energies ever observed from cosmic sources.

  2. Calibration and performance of the photon sensor response of FACT -- The First G-APD Cherenkov telescope

    CERN Document Server

    Biland, A; Buß, J; Commichau, V; Djambazov, L; Dorner, D; Einecke, S; Eisenacher, D; Freiwald, J; Grimm, O; von Gunten, H; Haller, C; Hempfling, C; Hildebrand, D; Hughes, G; Horisberger, U; Knoetig, M L; Krähenbühl, T; Lustermann, W; Lyard, E; Mannheim, K; Meier, K; Mueller, S; Neise, D; Overkemping, A -K; Paravac, A; Pauss, F; Rhode, W; Röser, U; Stucki, J -P; Steinbring, T; Temme, F; Thaele, J; Vogler, P; Walter, R; Weitzel, Q

    2014-01-01

    The First G-APD Cherenkov Telescope (FACT) is the first in-operation test of the performance of silicon photo detectors in Cherenkov Astronomy. For more than two years it is operated on La Palma, Canary Islands (Spain), for the purpose of long-term monitoring of astrophysical sources. For this, the performance of the photo detectors is crucial and therefore has been studied in great detail. Special care has been taken for their temperature and voltage dependence implementing a correction method to keep their properties stable. Several measurements have been carried out to monitor the performance. The measurements and their results are shown, demonstrating the stability of the gain below the percent level. The resulting stability of the whole system is discussed, nicely demonstrating that silicon photo detectors are perfectly suited for the usage in Cherenkov telescopes, especially for long-term monitoring purpose.

  3. The upgraded MAGIC Cherenkov telescopes

    Energy Technology Data Exchange (ETDEWEB)

    Tescaro, D., E-mail: dtescaro@iac.es [Instituto de Astrofísica de Canarias (IAC), E-38205 La Laguna, Tenerife (Spain); Universidad de La Laguna (ULL), Dept. Astrofísica, E-38206 La Laguna, Tenerife (Spain)

    2014-12-01

    The MAGIC Cherenkov telescopes underwent a major upgrade in 2011 and 2012. A new 1039-pixel camera and a larger area digital trigger system were installed in MAGIC-I, making it essentially identical to the newer MAGIC-II telescope. The readout systems of both telescopes were also upgraded, with fully programmable receiver boards and DRS4-chip-based digitization systems. The upgrade eased the operation and maintenance of the telescopes and also improved significantly their performance. The system has now an integral sensitivity as good as 0.6% of the Crab Nebula flux (for E>400GeV), with an effective analysis threshold at 70 GeV. This allows MAGIC to secure one of the leading roles among the current major ground-based Imaging Atmospheric Cherenkov telescopes for the next 5–10 years. - Highlights: • In 2011 and 2012 the MAGIC telescopes underwent a two-stage major upgrade. • The new camera of MAGIC-I allows us to exploit a 1.4 larger trigger area. • The novel DRS4-based readout systems allow a cost-effective ultra-fast digitization. • The upgrade greatly improved the maintainability of the system. • MAGIC has now an optimal integral sensitivity of 0.6% of the Crab Nebula flux.

  4. Distributed beam loss monitor based on the Cherenkov effect in an optical fiber

    Science.gov (United States)

    Maltseva, Yu; Emanov, F. A.; Petrenko, A. V.; Prisekin, V. G.

    2015-05-01

    This review discusses a distributed beam loss monitor which is based on the Cherenkov effect in an optical fiber and which has been installed at the VEPP-5 Injection Complex at the Budker Institute of Nuclear Physics. The principle of the device operation consists in detecting the Cherenkov radiation generated in an optical fiber by relativistic charged particles that are produced in an electromagnetic shower when highly relativistic beam particles (electrons or positrons) hit the accelerator vacuum chamber wall. Our experiments used a photomultiplier tube (PMT) to detect the Cherenkov light. Knowing when the PMT signal arrives tells us where the beam loss occurs. Using a 20-m-long optical fiber allowed a detector spatial resolution of 3 m. The way to improve the resolution is to optimize the monitor working conditions and optical fiber and PMT parameters, potentially leading to a resolution of as fine as 0.5 m according to our estimates.

  5. Scientific verification of High Altitude Water Cherenkov observatory

    Science.gov (United States)

    Marinelli, Antonio; Sparks, Kathryne; Alfaro, Ruben; González, María Magdalena; Patricelli, Barbara; Fraija, Nissim

    2014-04-01

    The High Altitude Water Cherenkov (HAWC) observatory is a TeV gamma-ray and cosmic-ray detector currently under construction at an altitude of 4100 m close to volcano Sierra Negra in the state of Puebla, Mexico. The HAWC [1] observatory is an extensive air-shower array composed of 300 optically isolated water Cherenkov detectors (WCDs). Each WCD contains ~200,000 l of filtered water and four upward-facing photomultiplier tubes. In Fall 2014, when the HAWC observatory will reach an area of 22,000 m2, the sensitivity will be 15 times higher than its predecessor Milagro [2]. Since September 2012, more than 30 WCDs have been instrumented and taking data. This first commissioning phase has been crucial for the verification of the data acquisition and event reconstruction algorithms. Moreover, with the increasing number of instrumented WCDs, it is important to verify the data taken with different configuration geometries. In this work we present a comparison between Monte Carlo simulation and data recorded by the experiment during 24 h of live time between 14 and 15 April of 2013 when 29 WCDs were active.

  6. Scientific verification of High Altitude Water Cherenkov observatory

    Energy Technology Data Exchange (ETDEWEB)

    Marinelli, Antonio, E-mail: antonio.marinelli@fisica.unam.mx [Instituto de Física, Universidad Nacional Autónoma de México, Mexico D.F. (Mexico); Sparks, Kathryne [Department of Physics, Pennsylvania State University, University Park, PA (United States); Alfaro, Ruben [Instituto de Física, Universidad Nacional Autónoma de México, Mexico D.F. (Mexico); González, María Magdalena; Patricelli, Barbara; Fraija, Nissim [Instituto de Astronomia, Universidad Nacional Autónoma de México, Mexico D.F. (Mexico)

    2014-04-01

    The High Altitude Water Cherenkov (HAWC) observatory is a TeV gamma-ray and cosmic-ray detector currently under construction at an altitude of 4100 m close to volcano Sierra Negra in the state of Puebla, Mexico. The HAWC [1] observatory is an extensive air-shower array composed of 300 optically isolated water Cherenkov detectors (WCDs). Each WCD contains ∼200,000 l of filtered water and four upward-facing photomultiplier tubes. In Fall 2014, when the HAWC observatory will reach an area of 22,000 m{sup 2}, the sensitivity will be 15 times higher than its predecessor Milagro [2]. Since September 2012, more than 30 WCDs have been instrumented and taking data. This first commissioning phase has been crucial for the verification of the data acquisition and event reconstruction algorithms. Moreover, with the increasing number of instrumented WCDs, it is important to verify the data taken with different configuration geometries. In this work we present a comparison between Monte Carlo simulation and data recorded by the experiment during 24 h of live time between 14 and 15 April of 2013 when 29 WCDs were active.

  7. Workshop on Non-Imaging Cherenkov at High Energy

    CERN Document Server

    2013-01-01

    The non-Imaging Cherenkov air shower measurement technique holds great promise in furthering our understanding the Knee-to-Ankle region of the cosmic ray spectrum. In particular, this technique offers a unique way to determine the evolution of the cosmic ray nuclear composition, and an example is given by the recent spectrum results of the Tunka Collaboration. With this in mind, we are organizing a workshop, to be held at the University of Utah, to bring together the various practitioners of this cosmic ray measurement technique to share simulations, analyses, detector designs, and past experimental results amongst the community. The workshop will also be in support of our effort, NICHE, to extend the reach of the TA/TALE detector systems down to the Knee. We anticipate that the workshop will result in a white paper on the scientific importance of these high-energy cosmic ray measurements and on using the Cherenkov technique to accomplish them. Our goal is to have contributions from members of the previous ge...

  8. Progress in Cherenkov femtosecond fiber lasers

    DEFF Research Database (Denmark)

    Liu, Xiaomin; Svane, Ask Sebastian; Lægsgaard, Jesper

    2016-01-01

    systems are highlighted—dependent on the realization scheme, the Cherenkov lasers can generate the femtosecond output tunable across the entire visible and even the UV range, and for certain designs more than 40% conversion efficiency from the pump to Cherenkov signal can be achieved. The femtosecond...... Cherenkov laser with all-fiber architecture is presented and discussed. Operating in the visible range, it delivers 100–200 fs wavelength-tunable pulses with multimilliwatt output power and exceptionally low noise figure an order of magnitude lower than the traditional wavelength tunable supercontinuumbased...

  9. Cherenkov and Scintillation Properties of Cubic Zirconium

    Science.gov (United States)

    Christl, M.J.; Adams, J.H.; Parnell, T.A.; Kuznetsov, E.N.

    2008-01-01

    Cubic zirconium (CZ) is a high index of refraction (n =2.17) material that we have investigated for Cherenkov counter applications. Laboratory and proton accelerator tests of an 18cc sample of CZ show that the expected fast Cherenkov response is accompanied by a longer scintillation component that can be separated by pulse shaping. This presents the possibility of novel particle spectrometers which exploits both properties of CZ. Other high index materials being examined for Cherenkov applications will be discussed. Results from laboratory tests and an accelerator exposure will be presented and a potential application in solar energetic particle instruments will be discussed

  10. The major atmospheric gamma-ray imaging Cherenkov telescope

    Science.gov (United States)

    Garczarczyk, Markus; MAGIC Collaboration

    2011-05-01

    MAGIC is a system of two 17 m diameter Imaging Atmospheric Cherenkov Telescopes (IACTs) for ground-based γ-ray astronomy. During many years, starting with the design phase of the first telescope in 2003, the upgrade of the second telescope in 2008 up to now, novel technologies have been developed, commissioned and continuously improved. Most components and subsystems represent nowadays state of the art techniques and are under consideration to be used in future detectors. The large reflector area, together with small diameter, high quantum efficiency (QE) photomultipliers (PMTs) in combination with an improved trigger and readout system permits an analysis threshold of 25 GeV, the lowest among current IACTs. MAGIC overlaps in energy with the upper end of current satellite experiments and gives the unique opportunity, for the first time, to cross-calibrate ground based versus satellite born detectors. Some selected techniques used in MAGIC, which are in context with this conference, are presented.

  11. A Prototype RICH Detector Using Multi-Anode Photo Multiplier Tubes and Hybrid Photo-Diodes

    CERN Document Server

    Albrecht, E; Bibby, J H; Brook, N H; Doucas, G; Duane, A; Easo, S; Eklund, L; French, M; Gibson, V; Gys, Thierry; Halley, A W; Harnew, N; John, M; Piedigrossi, D; Rademacker, J; Simmons, B; Smale, N J; Teixeira-Dias, P; Toudup, L W; Websdale, David M; Wilkinson, G R; Wotton, S A

    2001-01-01

    The performance of a prototype Ring Imaging Cherenkov Detector is studied using a charged particle beam. The detector performance, using CF4 and air as radiators, is described. Cherenkov angle precision and photoelectron yield using hybrid photo-diodes and multi-anode PMTs agree with simulations and are assessed in terms of the requirements of the LHCb experiment.

  12. INTENSITY INTERFEROMETRY WITH CHERENKOV TELESCOPES

    Directory of Open Access Journals (Sweden)

    D. B. Kieda

    2010-01-01

    Full Text Available Se discuten las capacidades de arreglos de interferometría de intensidad estelar (SII que se pueden construir usando la siguiente generación de arreglos de telescopios de Cherenkov de imágenes de aire (IACTs. Estos arreglos de IACT tendrán un gran diámetro de - 100 m (> 8 m de re ectores ópticos, ofreciendo cerca de 5000 líneas de base interferométricas, extendiéndose a partir de 50 m a más que 1000 m. La implementación del SII en arreglos de IACT permitirán imágenes de alta resolución (< 0:1 mas en anchos de banda cortos (bandas B/V, que son óptimas para el estudio de estrellas calientes.

  13. Cherenkov Telescope Array Data Management

    CERN Document Server

    Lamanna, G; Contreras, J L; Knödlseder, J; Kosack, K; Neyroud, N; Aboudan, A; Arrabito, L; Barbier, C; Bastieri, D; Boisson, C; Brau-Nogué, S; Bregeon, J; Bulgarelli, A; Carosi, A; Costa, A; De Cesare, G; Reyes, R de los; Fioretti, V; Gallozzi, S; Jacquemier, J; Khelifi, B; Kocot, J; Lombardi, S; Lucarelli, F; Lyard, E; Maier, G; Massimino, P; Osborne, J P; Perri, M; Rico, J; Sanchez, D A; Satalecka, K; Siejkowski, H; Stolarczyk, T; Szepieniec, T; Testa, V; Walter, R; Ward, J E; Zoli, A

    2015-01-01

    Very High Energy gamma-ray astronomy with the Cherenkov Telescope Array (CTA) is evolving towards the model of a public observatory. Handling, processing and archiving the large amount of data generated by the CTA instruments and delivering scientific products are some of the challenges in designing the CTA Data Management. The participation of scientists from within CTA Consortium and from the greater worldwide scientific community necessitates a sophisticated scientific analysis system capable of providing unified and efficient user access to data, software and computing resources. Data Management is designed to respond to three main issues: (i) the treatment and flow of data from remote telescopes; (ii) "big-data" archiving and processing; (iii) and open data access. In this communication the overall technical design of the CTA Data Management, current major developments and prototypes are presented.

  14. Proximity focusing RICH detector based on multilayer silica aerogel radiator

    CERN Document Server

    De Leo, R; Bellunato, T; Calvi, M; Cisbani, E; Cusanno, F; Garibaldi, F; Lagamba, L; Marra, M; Marrone, S; Matteuzzi, C; Musico, P; Nappi, E; Perego, D L; Torrioli, S; Vilardi, I

    2010-01-01

    The performance of a proximity focusing Ring Imaging Cherenkov detector equipped with a radiator of silica aerogel is presented. The aerogel tile used is a monolith with variable index of refraction. Cherenkov photons are detected with high granularity by eight Hamamatsu H9500 flat panel multi anode phototubes.

  15. The study of CP violation in the B{sup 0} {yields} D{sup +}D{sup -} by means of the BABAR detector. Measurement of the performances of DIRC Cherenkov detector of BABAR: Prototype-II and final detector; L'etude de la violation de CP dans le canal B{sup 0} {yields} D{sup +}D{sup -} a l'aide du detecteur BABAR. La mesure des performances du detecteur Cerenkov DIRC de BABAR: Prototype -II et detecteur final

    Energy Technology Data Exchange (ETDEWEB)

    Benkebil, Mehdi [Lab. de l' Accelerateur Lineaire, Paris-11 Univ., 91 - Orsay (France)

    1999-04-16

    The work presented in this thesis is divided into two parts: the physics analysis of the decay mode B{sup 0} {yields} D{sup +}D{sup -} and the performance obtained with a new type of a particle identification detector using the Cherenkov effect technique: the DIRC. The analysis of this decay mode has been performed with data generated from fast simulation and a preliminary version of the reconstruction program. The branching ratio of this channel is predicted to be 4.5 x 10{sup -4}. The uncertainty in the sin 2 {beta} measurement obtained with this mode is: {sigma}(sin 2{beta})0.19 and 0.32 for fast simulation and preliminary version of the reconstruction program, respectively. The comparison of this result with the one obtained in the B{sup 0} {yields} J/{psi}K{sub s}{sup 0} mode will bring very useful theoretical insights. The performance study of the DIRC has been done on the prototype-II and the final detector. The beam-test results in terms resolution on the {theta}{sub c} angle and number of Cherenkov photons are the following: {sigma}({theta}{sub c}) = 10.2 {+-} 0.1 mrad per photon, {sigma}({theta}{sub c}) = 3.2 {+-} 0.2 mrad per track and N{sub {gamma}} 15.7 {+-} 0.1 at {theta}{sub dip} = 20 angle and 0 transmission in the bar. The analysis of the first cosmic data collected by the BABAR detector has allowed to study the DIRC in its final configuration. Among all the results obtained, we give the following ones: {sigma}({theta}{sub c}) = 10.09 {+-} 0.06 mrad per photon, {sigma}({theta}{sub c}) = 4.71 {+-} 0.14 mrad per track and N{sub {gamma}} 35.2 {+-} 3.8 at {theta}{sub dip} = 20 angle and 0 transmission in the bar. The extrapolation to the real condition of BABAR for all these results shows that the DIRC will run with performances similar to the nominal values. A detailed study of the background shows that, even though it will not be negligible, it will not compromise the DIRC performances in BABAR.

  16. All-fiber femtosecond Cherenkov radiation source

    DEFF Research Database (Denmark)

    Liu, Xiaomin; Lægsgaard, Jesper; Møller, Uffe

    2012-01-01

    An all-fiber femtosecond source of spectrally isolated Cherenkov radiation is reported, to the best of our knowledge, for the first time. Using a monolithic, self-starting femtosecond Yb-doped fiber laser as the pump source and the combination of photonic crystal fibers as the wave-conversion med......An all-fiber femtosecond source of spectrally isolated Cherenkov radiation is reported, to the best of our knowledge, for the first time. Using a monolithic, self-starting femtosecond Yb-doped fiber laser as the pump source and the combination of photonic crystal fibers as the wave......-conversion medium, we demonstrate milliwatt-level, stable, and tunable Cherenkov radiation at visible wavelengths 580–630 nm, with pulse duration of sub-160-fs, and the 3 dB spectral bandwidth not exceeding 36 nm. Such an all-fiber Cherenkov radiation source is promising for practical applications in biophotonics...

  17. Astroparticle Physics: Detectors for Cosmic Rays

    Science.gov (United States)

    Salazar, Humberto; Villaseñor, Luis

    2006-09-01

    We describe the work that we have done over the last decade to design and construct instruments to measure properties of cosmic rays in Mexico. We describe the measurement of the muon lifetime and the ratio of positive to negative muons in the natural background of cosmic ray muons at 2000 m.a.s.l. Next we describe the detection of decaying and crossing muons in a water Cherenkov detector as well as a technique to separate isolated particles. We also describe the detection of isolated muons and electrons in a liquid scintillator detector and their separation. Next we describe the detection of extensive air showers (EAS) with a hybrid detector array consisting of water Cherenkov and liquid scintillator detectors, located at the campus of the University of Puebla. Finally we describe work in progress to detect EAS at 4600 m.a.s.l. with a water Cherenkov detector array and a fluorescence telescope at the Sierra Negra mountain.

  18. Status of the KEDR detector

    CERN Document Server

    Anashin, V V; Baibusinov, B O; Balashov, V; Baldin, E M; Barkov, L M; Barladyan, A K; Barnyakov, M Y; Baru, S E; Bedny, I; Beilin, D M; Blinov, A E; Blinov, V E; Bondarev, D V; Bondar, A E; Buzykaev, A R; Cantoni, P; Chilingarov, A G; Dneprovsky, L V; Eidelman, S I; Epifanov, D A; Frabetti, P L; Gaidarev, P B; Groshev, V R; Karpov, S V; Kiselev, V A; Klimenko, S G; Kolachev, G M; Kononov, S A; Kozlov, V N; Kravchenko, E A; Kulikov, V F; Kurdadze, L M; Kuzmin, A S; Kuznecov, S A; Lanni, F; Lelchuk, M Y; Leontiev, L A; Levichev, E B; Malyshev, V M; Manfredi, P F; Maslennikov, A L; Minakov, G D; Nagaslaev, V P; Naumenkov, A I; Nikitin, S A; Nomerotski, A; Onuchin, A P; Oreshkin, S B; Ovechkin, R; Palombo, F; Peleganchuk, S V; Petrosyan, S S; Pivovarov, S V; Poluektov, A O; Pospelov, G E; Protopopov, I Ya; Re, V; Romanov, L V; Root, N I; Ruban, A A; Savinov, G A; Shamov, A G; Shatilov, D; Shubin, M A; Shusharo, A I; Shwartz, B A; Sidorov, V A; Skovpen, Y I; Smakhtin, V P; Snopkov, R G; Sokolov, A V; Soukharev, A M; Talyshev, A A; Tayursky, V A; Telnov, V I; Tikhonov, Yu A; Todyshev, K Y; Usov, Y V; Vorobyev, A I; Yushkov, A N; Zatcepin, A V; Zhilich, V N

    2002-01-01

    KEDR is a general-purpose detector for experiments at the VEPP-4M e sup + e sup - -collider in the energy range 2E=2.0-12 GeV. All detector subsystems (except the aerogel Cherenkov counters) have been installed into the detector at VEPP-4M. Some preliminary data have been taken in the energy region of the J/PSI meson. The tuning of the detector and the VEPP-4M collider is in progress. Preliminary results on the detector performance are presented. The future experimental program for the KEDR detector is discussed.

  19. Status of the KEDR detector

    Energy Technology Data Exchange (ETDEWEB)

    Anashin, V.V.; Aulchenko, V.M.; Baibusinov, B.O.; Balashov, V.; Baldin, E.M.; Barkov, L.M.; Barladyan, A.K.; Barnyakov, M.Yu.; Baru, S.E.; Bedny, I.V.; Beilin, D.M.; Blinov, A.E.; Blinov, V.E.; Bondarev, D.V.; Bondar, A.E.; Buzykaev, A.R.; Cantoni, P.; Chilingarov, A.G.; Dneprovsky, L.V.; Eidelman, S.I.; Epifanov, D.A.; Frabetti, P.L.; Gaidarev, P.B.; Groshev, V.R.; Karpov, S.V.; Kiselev, V.A.; Klimenko, S.G.; Kolachev, G.M.; Kononov, S.A.; Kozlov, V.N.; Kravchenko, E.A.; Kulikov, V.F.; Kurdadze, L.M.; Kuzmin, A.S.; Kuznecov, S.A.; Lanni, F.; Lelchuk, M.Yu.; Leontiev, L.A.; Levichev, E.B.; Malyshev, V.M.; Manfredi, P.F.; Maslennikov, A.L.; Minakov, G.D.; Nagaslaev, V.P.; Naumenkov, A.; Nikitin, S.A.; Nomerotsky, A.; Onuchin, A.P.; Oreshkin, S.B.; Ovechkin, R.; Palombo, F.; Peleganchuk, S.V.; Petrosyan, S.S.; Pivovarov, S.V.; Poluektov, A.O.; Pospelov, G.E.; Protopopov, I.Ya.; Re, V.; Romanov, L.V.; Root, N.I.; Ruban, A.A.; Savinov, G.A.; Shamov, A.G.; Shatilov, D.; Shubin, M.A.; Shusharo, A.I.; Shwartz, B.A.; Sidorov, V.A.; Skovpen, Yu.I.; Smakhtin, V.P.; Snopkov, R.G.; Sokolov, A.V.; Soukharev, A.M.; Talyshev, A.A.; Tayursky, V.A.; Telnov, V.I.; Tikhonov, Yu.A. E-mail: tikhonov@cppm.in2p3.fr; Todyshev, K.Yu.; Usov, Yu.V.; Vorobyev, A.I.; Yushkov, A.N.; Zatcepin, A.V.; Zhilich, V.N

    2002-02-01

    KEDR is a general-purpose detector for experiments at the VEPP-4M e{sup +}e{sup -}-collider in the energy range 2E=2.0-12 GeV. All detector subsystems (except the aerogel Cherenkov counters) have been installed into the detector at VEPP-4M. Some preliminary data have been taken in the energy region of the J/{psi} meson. The tuning of the detector and the VEPP-4M collider is in progress. Preliminary results on the detector performance are presented. The future experimental program for the KEDR detector is discussed.

  20. System Test of a Prototype LHCb RICH Detector

    CERN Document Server

    Patel, M

    2004-01-01

    A prototype of the LHCb Ring Imaging Cherenkov detector has been constructed. The prototype module contained a pre-production Pixel Hybrid Photon Detector, mounted on the final photon detector mechanics. The photon detector was read out at the full LHC speed of 40 MHz using the full prototype on-detector RICH electronics readout chain. The readout uses radiation-tolerant FPGA technology, 1.6 GHz optical links and 40 MHz trigger-timing and control (TTC). The photon detector was mounted in a gas vessel and Cherenkov rings have been observed from and N$_2$ radiator using electron and pion beams.

  1. 110th anniversary of the birth of P A Cherenkov (Scientific session of the Physical Sciences Division of the Russian Academy of Sciences, 17 December 2014)

    Science.gov (United States)

    2015-05-01

    A scientific session of the Physical Sciences Division of the Russian Academy of Sciences (RAS) was held on 17 December 2014 at the conference hall of the Lebedev Physical Institute, RAS, devoted to the 110th anniversary of the birth of Academician P A Cherenkov. The agenda posted on the website of the Physical Sciences Division RAS http://www.gpad.ac.ru comprised the following reports: (1) Bashmakov Yu A (Lebedev Physical Institute, RAS, Moscow) "Prehistory of discovery"; (2) Kadmensky S G (Voronezh State University, Voronezh) "Cherenkov radiation as a serendipity phenomenon"; (3) Denisov S P (Russian Federation State Scientific Center 'Institute for High Energy Physics' of National Research Center 'Kurchatov Institute', Protvino, Moscow region) "Use of Cherenkov counters in accelerator experiments"; (4) Petrukhin A A (National Research Nuclear University 'MEPhI', Moscow) "Cherenkov NEVOD water detector"; (5) Dremin I M (Lebedev Physical Institute, RAS, Moscow) "Cherenkov radiation from gluons in a nuclear medium"; (6) Domogatsky G V (Institute for Nuclear Research, RAS, Moscow) "Cherenkov detectors for high-energy neutrino astrophysics"; (7) Kravchenko E A (Budker Institute of Nuclear Physics, SB RAS, Novosibirsk) "Cherenkov detectors with aerogel radiators"; (8) Malinovski E I (Institute for Nuclear Research, RAS, Moscow) "Cherenkov total absorption spectrometers for high-energy electrons and photons"; (9) Maltseva Yu I (Budker Institute of Nuclear Physics, SB RAS, Novosibirsk) "Distributed beam loss monitor based on the Cherenkov effect in an optical fiber". Papers based on oral reports 1-4, 6-9 are presented below. Some aspects of report 5 can be found in the review by I M Dremin and A V Leonidov published in 2010 in Physics-Uspekhi (Vol. 53, p. 1123). • Cherenkov radiation: from discovery to RICH, Yu A Bashmakov Physics-Uspekhi, 2015, Volume 58, Number 5, Pages 467-471 • Cherenkov radiation as a serendipitous phenomenon, S G Kadmensky Physics

  2. Strange meson spectroscopy in K[omega] and K[phi] at 11 GeV/c and Cherenkov ring imaging at SLD

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Youngjoon.

    1993-01-01

    This thesis consists of two independent parts; development of Cherenkov Ring Imaging Detector (CRID) system and analysis of high-statistics data of strange meson reactions from the LASS spectrometer. Part 1: The CRID system is devoted to charged particle identification in the SLAC Large Detector (SLD) to study e[sup +]e[sup [minus

  3. Temporal signatures of the Cherenkov light induced by extensive air showers of cosmic rays detected with the Yakutsk array

    Science.gov (United States)

    Ivanov, A. A.; Timofeev, L. V.

    2016-05-01

    We analyze temporal characteristics of signals from the wide field-of-view (WFOV) Cherenkov telescope (CT) detecting extensive air showers (EAS) of cosmic rays (CRs) in coincidence with surface detectors of the Yakutsk array. Our aim is to reveal causal relationships between measured characteristics and physical properties of EAS.

  4. Temporal signatures of the Cherenkov light induced by extensive air showers of cosmic rays detected with the Yakutsk array

    CERN Document Server

    Ivanov, A A

    2016-01-01

    We analyze temporal characteristics of signals from the wide field-of-view (WFOV) Cherenkov telescope (CT) detecting extensive air showers (EAS) of cosmic rays (CR) in coincidence with surface detectors of the Yakutsk array. Our aim is to reveal causal relationships between measured characteristics and physical properties of EAS.

  5. FACT -- The G-APD revolution in Cherenkov astronomy

    CERN Document Server

    Bretz, T; Backes, M; Biland, A; Boccone, V; Braun, I; Buß, J; Cadoux, F; Commichau, V; Djambazov, L; Dorner, D; Einecke, S; Eisenacher, D; Gendotti, A; Grimm, O; von Gunten, H; Haller, C; Hempfling, C; Hildebrand, D; Horisberger, U; Huber, B; Kim, K S; Knoetig, M L; Köhne, J H; Krähenbühl, T; Krumm, B; Lee, M; Lorenz, E; Lustermann, W; Lyard, E; Mannheim, K; Meharga, M; Meier, K; Müuller, S; Montaruli, T; Neise, D; Nessi-Tedaldi, F; Overkemping, A K; Paravac, A; Pauss, F; Renker, D; Rhode, W; Ribordy, M; Röser, U; Stucki, J P; Schneider, J; Steinbring, T; Temme, F; Thaele, J; Tobler, S; Viertel, G; Vogler, P; Walter, R; Warda, K; Weitzel, Q; Zänglein, M

    2014-01-01

    Since two years, the FACT telescope is operating on the Canary Island of La Palma. Apart from its purpose to serve as a monitoring facility for the brightest TeV blazars, it was built as a major step to establish solid state photon counters as detectors in Cherenkov astronomy. The camera of the First G-APD Cherenkov Telesope comprises 1440 Geiger-mode avalanche photo diodes (G-APD), equipped with solid light guides to increase the effective light collection area of each sensor. Since no sense-line is available, a special challenge is to keep the applied voltage stable although the current drawn by the G-APD depends on the flux of night-sky background photons significantly varying with ambient light conditions. Methods have been developed to keep the temperature and voltage dependent response of the G-APDs stable during operation. As a cross-check, dark count spectra with high statistics have been taken under different environmental conditions. In this presentation, the project, the developed methods and the e...

  6. NECTAr: New electronics for the Cherenkov Telescope Array

    Energy Technology Data Exchange (ETDEWEB)

    Vorobiov, S., E-mail: vorobiov@lpta.in2p3.f [LPTA, Universite Montpellier II and IN2P3/CNRS, Montpellier (France); Bolmont, J.; Corona, P. [LPNHE, Universite Paris VI and IN2P3/CNRS, Paris (France); Delagnes, E. [IRFU/DSM/CEA, Saclay, Gif-sur-Yvette (France); Feinstein, F. [LPTA, Universite Montpellier II and IN2P3/CNRS, Montpellier (France); Gascon, D. [ICC-UB, Universitat Barcelona, Barcelona (Spain); Glicenstein, J.-F. [IRFU/DSM/CEA, Saclay, Gif-sur-Yvette (France); Naumann, C.L.; Nayman, P. [LPNHE, Universite Paris VI and IN2P3/CNRS, Paris (France); Sanuy, A. [ICC-UB, Universitat Barcelona, Barcelona (Spain); Toussenel, F.; Vincent, P. [LPNHE, Universite Paris VI and IN2P3/CNRS, Paris (France)

    2011-05-21

    The European astroparticle physics community aims to design and build the next generation array of Imaging Atmospheric Cherenkov Telescopes (IACTs), that will benefit from the experience of the existing H.E.S.S. and MAGIC detectors, and further expand the very-high energy astronomy domain. In order to gain an order of magnitude in sensitivity in the 10 GeV to >100TeV range, the Cherenkov Telescope Array (CTA) will employ 50-100 mirrors of various sizes equipped with 1000-4000 channels per camera, to be compared with the 6000 channels of the final H.E.S.S. array. A 3-year program, started in 2009, aims to build and test a demonstrator module of a generic CTA camera. We present here the NECTAr design of front-end electronics for the CTA, adapted to the trigger and data acquisition of a large IACTs array, with simple production and maintenance. Cost and camera performances are optimized by maximizing integration of the front-end electronics (amplifiers, fast analog samplers, ADCs) in an ASIC, achieving several GS/s and a few {mu}s readout dead-time. We present preliminary results and extrapolated performances from Monte Carlo simulations.

  7. Characterization study of silica aerogel for Cherenkov imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sallaz-Damaz, Y. [LPSC, IN2P3/CNRS, 53 av. des Martyrs, 38026 Grenoble Cedex (France); Derome, L., E-mail: derome@lpsc.in2p3.f [LPSC, IN2P3/CNRS, 53 av. des Martyrs, 38026 Grenoble Cedex (France); Mangin-Brinet, M.; Loth, M.; Protasov, K.; Putze, A.; Vargas-Trevino, M.; Veziant, O.; Buenerd, M. [LPSC, IN2P3/CNRS, 53 av. des Martyrs, 38026 Grenoble Cedex (France); Menchaca-Rocha, A.; Belmont, E.; Vargas-Magana, M.; Leon-Vargas, H.; Ortiz-Velasquez, A. [Instituto de Fisica, UNAM, AP 20-364, Mexico DF (Mexico); Malinine, A. [University of Maryland, College Park, MD 20742 (United States); Barao, F.; Pereira, R. [LIP, Avenida Elias Garcia 14-1, P - 1000 Lisboa (Portugal); Bellunato, T.; Matteuzzi, C.; Perego, D.L. [Universita degli Studi di Milano-Bicocca and INFN, Milano (Italy)

    2010-03-01

    Different methods to measure the characteristics of silica aerogel tiles used as Cherenkov radiator in the CREAM and AMS experiments have been investigated to optimize the detector performances. The measurement accuracy dictated by the physics objectives on the velocity and charge resolutions set stringent requirements on the aerogel refractive index determination, namely DELTAnapprox1.5x10{sup -4} and DELTAnapprox5x10{sup -4} for the AMS and CREAM imagers, respectively. The matching of such accuracies for this material turned out to be a metrological challenge, and finally led to a full R and D program, to develop an appropriate characterization procedure. Preliminary studies performed with a standard refractive index measurement technique (laser beam deviation by a prism) have revealed a significant systematic index nonuniformity for the AMS tiles at a level (10{sup -3}), not acceptable considering the aimed accuracy. These large variations were confirmed in a beam test. A second method, mapping the transverse index gradient by deflection of a laser beam entering normally to the tile has then been developed. It is shown that this procedure is suitable to reach the required accuracy, at the price of using both methods combined. The several hundreds of tiles of the radiator plane of the CREAM and AMS Cherenkov imagers were characterized using a simplified procedure, however, appropriate for each case, compromising between the amount of work and the time available. The experimental procedures and set-ups used are described in the text, and the obtained results are reported.

  8. The HERA-B ring imaging Cherenkov counter

    Energy Technology Data Exchange (ETDEWEB)

    Arino, I.; Bastos, J.; Broemmelsiek, D.; Carvalho, J.; Chmeissani, M.; Conde, P.; Davila, J.; Dujmic, D.; Eckmann, R.; Garrido, L.; Gascon, D.; Hamacher, T.; Gorisek, A.; Ivaniouchenkov, I.; Ispirian, M.; Karabekian, S.; Kim, M.; Korpar, S.; Krizan, P. E-mail: peter.krizan@ijs.si; Kupper, S.; Lau, K.; Maas, P.; McGill, J.; Miquel, R.; Murthy, N.; Peralta, D.; Pestotnik, R.; Pyrlik, J.; Ramachandran, S.; Reeves, K.; Rosen, J.; Schmidt-Parzefall, W.; Schwarz, A.; Schwitters, R.F.; Siero, X.; Staric, M.; Stanovnik, A.; Skrk, D.; Zivko, T

    2004-01-11

    The HERA-B RICH uses a radiation path length of 2.8 m in C{sub 4}F{sub 10} gas and a large 24 m{sup 2} spherical mirror for imaging Cherenkov rings. The photon detector consists of 2240 Hamamatsu multi-anode photomultipliers with about 27 000 channels. A 2:1 reducing two-lens telescope in front of each photomultiplier tube increases the sensitive area at the expense of increased pixel size, resulting in a contribution to the resolution which roughly matches that of dispersion. The counter was completed in January of 1999, and its performance has been steady and reliable over the years it has been in operation. The design performance of the Ring Imaging Cherenkov counter was fully reached: the average number of detected photons in the RICH for a {beta}=1 particle was found to be 33 with a single-hit resolution of 0.7 and 1 mrad in the fine and coarse granularity regions, respectively.

  9. The HERA-B ring imaging Cherenkov counter

    Science.gov (United States)

    Ariño, I.; Bastos, J.; Broemmelsiek, D.; Carvalho, J.; Chmeissani, M.; Conde, P.; Davila, J.; Dujmić, D.; Eckmann, R.; Garrido, L.; Gascon, D.; Hamacher, T.; Gorišek, A.; Ivaniouchenkov, I.; Ispirian, M.; Karabekian, S.; Kim, M.; Korpar, S.; Križan, P.; Kupper, S.; Lau, K.; Maas, P.; McGill, J.; Miquel, R.; Murthy, N.; Peralta, D.; Pestotnik, R.; Pyrlik, J.; Ramachandran, S.; Reeves, K.; Rosen, J.; Schmidt-Parzefall, W.; Schwarz, A.; Schwitters, R. F.; Siero, X.; Starič, M.; Stanovnik, A.; Škrk, D.; Živko, T.

    2004-01-01

    The HERA-B RICH uses a radiation path length of 2.8 m in C 4F 10 gas and a large 24 m2 spherical mirror for imaging Cherenkov rings. The photon detector consists of 2240 Hamamatsu multi-anode photomultipliers with about 27 000 channels. A 2:1 reducing two-lens telescope in front of each photomultiplier tube increases the sensitive area at the expense of increased pixel size, resulting in a contribution to the resolution which roughly matches that of dispersion. The counter was completed in January of 1999, and its performance has been steady and reliable over the years it has been in operation. The design performance of the Ring Imaging Cherenkov counter was fully reached: the average number of detected photons in the RICH for a β=1 particle was found to be 33 with a single-hit resolution of 0.7 and 1 mrad in the fine and coarse granularity regions, respectively.

  10. Highlights from the High Altitude Water Cherenkov Observatory

    CERN Document Server

    Pretz, John

    2015-01-01

    The High Altitude Water Cherenkov (HAWC) Gamma-Ray Observatory was completed this year at a 4100-meter site on the flank of the Sierra Negra volcano in Mexico. HAWC is a water Cherenkov ground array with the capability to distinguish 100 GeV - 100 TeV gamma rays from the hadronic cosmic-ray background. HAWC is uniquely suited to study extremely high energy cosmic-ray sources, search for regions of extended gamma-ray emission, and to identify transient gamma-ray phenomena. HAWC will play a key role in triggering multi-wavelength and multi-messenger studies of active galaxies, gamma-ray bursts, supernova remnants and pulsar wind nebulae. Observation of TeV photons also provide unique tests for a number of fundamental physics phenomena including dark matter annihilation and primordial black hole evaporation. Operation began mid-2013 with the partially-completed detector. Multi-TeV emission from the Galactic Plane is clearly seen in the first year of operation, confirming a number of known TeV sources, and a numb...

  11. Performance of a prototype RICH detector using hybrid photo-diodes

    CERN Document Server

    Albrecht, E; Bibby, J H; Brook, N H; Duane, A; French, M; Gibson, V; Giles, R; Halley, A W; Harnew, N; John, M; Miller, D G; O'Shea, V; Teixeira-Dias, P; Smale, N J; Websdale, David M; Wilkinson, G R; Wotton, S A

    2001-01-01

    A prototype Ring-Imaging Cherenkov detector has been operated in a charged particle test beam, Cherenkov photons are imaged onto a plane of hybrid photo-diode detectors. The geometrical arrangement of the prototype and data-taking conditions are described. An analysis of the detector performance, using silica aerogel, air and C/sub 4/F/sub 10/ gas radiators, is presented. The photon yields and observed Cherenkov angle resolutions are found to be in good agreement with Monte Carlo simulation and satisfy the requirements of the RICH 1 detector in the LHCb experiment. (14 refs).

  12. Particlc detectors. Foundations and applications; Teilchendetektoren. Grundlagen und Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Kolanoski, Hermann; Wermes, Norbert

    2016-08-01

    The following topics are dealt with: Interaction of particles with matter, motion of charge carriers in electric and magnetic fields, signal generation by moving charges, non-electronic detectors, gas-filled detectors, semiconductor detectors, track reconstruction and momentum measurement, photodetectors, Cherenkov detectors, transition-radiation detectors, scintillation detectors, particle identification, calorimeters, detection of cosmic particles, signal processing and noise, trigger and data acquisition systems. (HSI)

  13. First year results of the High Altitude Water Cherenkov observatory

    CERN Document Server

    Carramiñana, Alberto

    2016-01-01

    The High Altitude Water Cherenkov (HAWC) gamma-ray observatory is a wide field of view (1.8 Sr) and high duty cycle (>95% up-time) detector of unique capabilities for the study of TeV gamma-ray sources. Installed at an altitude of 4100m in the Northern slope of Volc\\'an Sierra Negra, Puebla, by a collaboration of about thirty institutions of Mexico and the United States, HAWC has been in full operations since March 2015, surveying 2/3 of the sky every sidereal day, monitoring active galaxies and mapping sources in the Galactic Plane to a detection level of 1 Crab per day. This contribution summarizes the main results of the first year of observations of the HAWC gamma-ray observatory.

  14. First year results of the High Altitude Water Cherenkov observatory

    Science.gov (United States)

    Carramiñana, Alberto

    2016-10-01

    The High Altitude Water Cherenkov (HAWC) γ-ray observatory is a wide field of view (1.8 Sr) and high duty cycle (> 95% up-time) detector of unique capabilities for the study of TeV gamma-ray sources. Installed at an altitude of 4100m in the Northern slope of Volcan Sierra Negra, Puebla, by a collaboration of about thirty institutions of Mexico and the United States, HAWC has been in full operations since March 2015, surveying 2/3 of the sky every sidereal day, monitoring active galaxies and mapping sources in the Galactic Plane to a detection level of 1 Crab per day. This contribution summarizes the main results of the first year of observations of the HAWC γ-ray observatory.

  15. A New Light Boson from Cherenkov Telescopes Observations?

    CERN Document Server

    Roncadelli, Marco; Mansutti, Oriana

    2010-01-01

    Early indications by H.E.S.S. and the subsequent detection of blazar 3C279 by MAGIC show that the Universe is more transparent to very-high-energy gamma rays than previously thought. We demonstrate that this circumstance can be reconciled with standard blazar emission models provided that photon oscillations into a very light Axion-Like Particle occur in extragalactic magnetic fields. A quantitative estimate of this effect indeed explains the observed spectrum of 3C279. Our prediction can be tested by the satellite-borne Fermi/LAT detector as well as by the ground-based Imaging Atmospheric Cherenkov Telescopes H.E.S.S., MAGIC, CANGAROO III, VERITAS and by the Extensive Air Shower arrays ARGO-YBJ and MILAGRO.

  16. Volcanoes muon imaging using Cherenkov telescopes

    CERN Document Server

    Catalano, Osvaldo; Mineo, Teresa; Cusumano, Giancarlo; Maccarone, Maria Concetta; Pareschi, Giovanni

    2015-01-01

    A detailed understanding of a volcano inner structure is one of the key-points for the volcanic hazards evaluation. To this aim, in the last decade, geophysical radiography techniques using cosmic muon particles have been proposed. By measuring the differential attenuation of the muon flux as a function of the amount of rock crossed along different directions, it is possible to determine the density distribution of the interior of a volcano. Up to now, a number of experiments have been based on the detection of the muon tracks crossing hodoscopes, made up of scintillators or nuclear emulsion planes. Using telescopes based on the atmospheric Cherenkov imaging technique, we propose a new approach to study the interior of volcanoes detecting the Cherenkov light produced by relativistic cosmic-ray muons that survive after crossing the volcano. The Cherenkov light produced along the muon path is imaged as a typical annular pattern containing all the essential information to reconstruct particle direction and energ...

  17. Cherenkov TOF PET with silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Dolenec, R., E-mail: rok.dolenec@ijs.si [Faculty of Chemistry and Chemical Engineering, University of Maribor, Maribor (Slovenia); Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia); Faculty of Mathematics and Physics, University of Ljubljana, Ljubljana (Slovenia); Korpar, S. [Faculty of Chemistry and Chemical Engineering, University of Maribor, Maribor (Slovenia); Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia); Križan, P. [Faculty of Mathematics and Physics, University of Ljubljana, Ljubljana (Slovenia); Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia); Pestotnik, R. [Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia)

    2015-12-21

    As previously demonstrated, an excellent timing resolution below 100 ps FWHM is possible in time-of-flight positron emission tomography (TOF PET) if the detection method is based on the principle of detecting photons of Cherenkov light, produced in a suitable material and detected by microchannel plate photomultipliers (MCP PMTs). In this work, the silicon photomultipliers (SiPMs) were tested for the first time as the photodetectors in Cherenkov TOF PET. The high photon detection efficiency (PDE) of SiPMs led to a large improvement in detection efficiency. On the other hand, the time response of currently available SiPMs is not as good as that of MCP PMTs. The SiPM dark counts introduce a new source of random coincidences in Cherenkov method, which would be overwhelming with present SiPM technology at room temperature. When the apparatus was cooled, its performance significantly improved.

  18. The Cherenkov Radiation for Non-Trivial Systems; La Radiacion Cherenkov en Sistemas No Triviales

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.

    2002-07-01

    The charge pathways and the dielectric properties of the medium are two essential aspects to be considered in the study of the emission of Cherenkov radiation. We described the evolution of the Cherenkov wavefront when the charges follow circular or helical pathways. Also we derive expressions for the refractive Index in different transparent media (solid, liquid or gas), focusing our attention on optically active plasmas. The optical analogies between the plasma and the birefringent crystals is studied in detail. Finally, we list some examples of plasmas, which can be considered emitters of Cherenkov radiation. (Author) 52 refs.

  19. Flipping photons backward: reversed Cherenkov radiation

    Directory of Open Access Journals (Sweden)

    Hongsheng Chen

    2011-01-01

    Full Text Available Charged particles moving faster than light in a medium produce Cherenkov radiation. In traditional, positive index-of-refraction materials this radiation travels forward. Metamaterials, with negative indices of refraction, flip the radiation backward. This readily separates it from the particles, providing higher flexibility in photon manipulation and is useful for particle identification and counting. Here we review recent advances in reversed Cherenkov radiation research, including the first demonstration of backward emission. We also discuss the potential for developing new types of devices, such as ones that pierce invisibility cloaks.

  20. Monitoring of absolute mirror alignment at COMPASS RICH-1 detector

    NARCIS (Netherlands)

    Alexeev, M.; Birsa, R.; Bradamante, F.; Bressan, A.; Chiosso, M.; Ciliberti, P.; Dalla Torre, S.; Denisov, O.; Duic, V.; Ferrero, A.; Finger, M.; Finger, M.; Gayde, J. Ch; Giorgi, M.; Gobbo, B.; Levorato, S.; Maggiora, A.; Martin, A.; Menon, G.; Panzieri, D.; Pesaro, G.; Polak, J.; Rocco, E.; Sbrizzai, G.; Schiavon, P.; Slunecka, M.; Sozzi, F.; Steiger, L.; Sulc, M.; Takekawa, S.; Tessarotto, F.

    2014-01-01

    The gaseous COMPASS RICH-1 detector uses two spherical mirror surfaces, segmented into 116 individual mirrors, to focus the Cherenkov photons onto the detector plane. Any mirror misalignment directly affects the detector resolution. The on-line Continuous Line Alignment and Monitoring (CLAM) photogr

  1. Development of the optical system for the SST-1M telescope of the Cherenkov Telescope Array observatory

    CERN Document Server

    Seweryn, K; Błocki, J.; Bogacz, L.; Bulik, T.; Cadoux, F.; Christov, A.; Chruślińska, M.; Curyło, M.; della Volpe, D.; Dyrda, M.; Favre, Y.; Frankowski, A.; Grudnik, Ł.; Grudzińska, M.; Heller, M.; Idźkowski, B.; Jamrozy, M.; Janiak, M.; Kasperek, J.; Lalik, K.; Lyard, E.; Mach, E.; Mandat, D.; Marszałek, A.; Michałowski, J.; Moderski, R.; Montaruli, T.; Neronov, A.; Niemiec, J.; Ostrowski, M.; Paśko, P.; Pech, M.; Porcelli, A.; Prandini, E.; Pueschel, E.; Rajda, P.; Rameez, M.; Rozwadowski, P.; Schioppa, E. jr; Schovanek, P.; Skowron, K.; Sliusar, V.; Sowiński, M.; Stawarz, Ł.; Stodulska, M.; Stodulski, M.; Toscano, S.; Pujadas, I. Troyano; Walter, R.; Wiȩcek, M.; Zagdański, A.; Ziȩtara, K.; Żychowski, P.; Barciński, T.; Karczewski, M.; Kukliński, J. Nicolau; Płatos, Ł.; Rataj, M.; Wawer, P.; Wawrzaszek, R.

    2015-01-01

    The prototype of a Davies-Cotton small size telescope (SST-1M) has been designed and developed by a consortium of Polish and Swiss institutions and proposed for the Cherenkov Telescope Array (CTA) observatory. The main purpose of the optical system is to focus the Cherenkov light emitted by extensive air showers in the atmosphere onto the focal plane detectors. The main component of the system is a dish consisting of 18 hexagonal mirrors with a total effective collection area of 6.47 m2 (including the shadowing and estimated mirror reflectivity). Such a solution was chosen taking into account the analysis of the Cherenkov light propagation and based on optical simulations. The proper curvature and stability of the dish is ensured by the mirror alignment system and the isostatic interface to the telescope structure. Here we present the design of the optical subsystem together with the performance measurements of its components.

  2. The SELEX Phototube RICH Detector

    CERN Document Server

    Engelfried, J; Kilmer, J; Kozhevnikov, A P; Kubarovskii, V P; Molchanov, V V; Nemitkin, A V; Ramberg, E; Rud, V I; Stutte, L

    1999-01-01

    In this article, construction, operation, and performance of the RICH detector of Fermilab experiment 781 (SELEX) are described. The detector utilizes a matrix of 2848 phototubes for the photocathode to detect Cherenkov photons generated in a 10m Neon radiator. For the central region an N0 of 104/cm, corresponding to 13.6 hits on a beta=1 ring, was obtained. The ring radius resolution measured is 1.6%.

  3. Summary of activity. Topic I: detectors and experiments. [High-energy detectors for use at ISABELLE

    Energy Technology Data Exchange (ETDEWEB)

    Marx, J; Ozaki, S

    1978-01-01

    Results of a workshop studying detectors for Isabelle experimental halls are described. The detectors must be very reliable. Spatial resolution of the tracking detectors must be high to provide accurate measurements of angle and momentum, retain a short resolving time, and show excellent multiparticle handling capability. Included in the study were hodoscopes, drift chambers, proportional chambers, time projection chambers, Cherenkov counters, electromagnetic shower detectors, and hadron calorimeters. Data handling methods were also included in the studies. (FS)

  4. Tachyonic Cherenkov radiation in the absorptive aether

    Energy Technology Data Exchange (ETDEWEB)

    Tomaschitz, Roman, E-mail: tom@geminga.org

    2014-08-14

    Dissipative tachyonic Cherenkov densities are derived and tested by performing a spectral fit to the γ-ray flux of supernova remnant (SNR) RX J1713.7 − 3946, measured over five frequency decades up to 100 TeV. The manifestly covariant formalism of tachyonic Maxwell–Proca radiation fields is developed in the spacetime aether, starting with the complex Lagrangian coupled to dispersive and dissipative permeability tensors. The spectral energy and flux densities of the radiation field are extracted by time averaging, the energy conservation law is derived, and the energy dissipation caused by the complex frequency-dependent permeabilities of the aether is quantified. The tachyonic mass-square in the field equations gives rise to transversally/longitudinally propagating flux components, with differing attenuation lengths determined by the imaginary part of the transversal/longitudinal dispersion relation. The spectral fit is performed with the classical tachyonic Cherenkov flux radiated by the shell-shocked electron plasma of SNR RX J1713.7 − 3946, exhibiting subexponential spectral decay. - Highlights: • Tachyonic Maxwell–Proca radiation fields in a dispersive and dissipative spacetime. • Transversal/longitudinal Poynting flux vector and associated spectral energy density. • Energy dissipation quantified by absorption term in the energy conservation law. • Dissipative Cherenkov densities (classical) and tachyonic attenuation lengths. • Cherenkov energy flux from the shocked electron plasma of SNR RX J1713.7 − 3946.

  5. Wide field-of-view Cherenkov telescope for the detection of cosmic rays in coincidence with the Yakutsk extensive air shower array

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, A.A., E-mail: ivanov@ikfia.ysn.ru; Knurenko, S.P.; Krasilnikov, A.D.; Petrov, Z.E.; Pravdin, M.I.; Sleptsov, I.Ye.; Timofeev, L.V.

    2015-02-01

    The Yakutsk array group is developing a wide field-of-view Cherenkov telescope to be operated in coincidence with the surface detectors of the extensive air shower array. Currently, the engineering prototype of the reflecting telescope with the front-end electronics is designed, assembled, and tested to demonstrate the feasibility of the conceived instrument. The status and specifications of the prototype telescope are presented, as well as the modernization program of the already existing Cherenkov light detectors subset of the array measuring ultra-high energy cosmic rays.

  6. Performance study of wavelength shifting acrylic plastic for Cherenkov light detection

    Energy Technology Data Exchange (ETDEWEB)

    Beckford, B., E-mail: beckford@aps.org [American Physical Society, One Physics Ellipse, College Park, MD 20740 (United States); De la Puente, A. [TRIUMF Laboratory, 4004 Wesbrook Mall, Vancouver, BC, Canada V6T 2A3 (Canada); Fujii, Y.; Hashimoto, O.; Kaneta, M.; Kanda, H.; Maeda, K.; Matsumura, A.; Nakamura, S.N. [Department of Physics, Tohoku University, Sendai 980-8578 (Japan); Perez, N.; Reinhold, J. [Department of Physics, Florida International University, Miami, FL 33199 (United States); Tang, L. [Department of Physics, Hampton University, Hampton, VA 23668 (United States); Tsukada, K. [Department of Physics, Tohoku University, Sendai 980-8578 (Japan)

    2014-01-21

    The collection efficiency for Cherenkov light incident on a wavelength shifting plate (WLS) has been determined during a beam test at the Proton Synchrotron facility located in the National Laboratory for High Energy Physics (KEK), Tsukuba, Japan. The experiment was conducted in order to determine the detector's response to photoelectrons converted from photons produced by a fused silica radiator; this allows for an approximation of the detector's quality. The yield of the photoelectrons produced through internally generated Cherenkov light as well as light incident from the radiator was measured as a function of the momentum of the incident hadron beam. The yield is proportional to sin{sup 2}θ{sub c}, where θ{sub c} is the opening angle of the Cherenkov light created. Based on estimations and results from similar conducted tests, where the collection efficiency was roughly 39%, the experimental result was expected to be around 40% for internally produced light from the WLS. The results of the experiment determined the photon collection response efficiency of the WLS to be roughly 62% for photons created in a fused silica radiator and 41% for light created in the WLS.

  7. Design and construction of a Cherenkov imager for charge measurement of nuclear cosmic rays

    CERN Document Server

    Bourrion, O; Bondoux, D; Bouly, J L; Bouvier, J; Boyer, B; Brinet, M; Buenerd, M; Damieux, G; Derome, L; Eraud, L; Foglio, R; Fombaron, D; Grondin, D; Lee, M H; Lutz, L; Marton, M; Menchaca-Rocha, A; Pelissier, A; Périé, J N; Putze, A; Roudier, S; Sallaz-Damaz, Y; Seo, E S; Scordilis, J P; Yoon, Y S

    2011-01-01

    A proximity focusing Cherenkov imager called CHERCAM, has been built for the charge measurement of nuclear cosmic rays with the CREAM instrument. It consists of a silica aerogel radiator plane across from a detector plane equipped with 1,600 1" diameter photomultipliers. The two planes are separated by a ring expansion gap. The Cherenkov light yield is proportional to the charge squared of the incident particle. The expected relative light collection accuracy is in the few percents range. It leads to an expected single element separation over the range of nuclear charge Z of main interest 1 < Z < 26. CHERCAM is designed to fly with the CREAM balloon experiment. The design of the instrument and the implemented technical solutions allowing its safe operation in high altitude conditions (radiations, low pressure, cold) are presented.

  8. Design and construction of a Cherenkov imager for charge measurement of nuclear cosmic rays

    Energy Technology Data Exchange (ETDEWEB)

    Bourrion, O; Bernard, C; Bondoux, D; Bouly, J L; Bouvier, J; Boyer, B; Brinet, M; Buenerd, M; Damieux, G; Derome, L; Eraud, L; Foglio, R; Fombaron, D; Grondin, D; Marton, M; Pelissier, A [Laboratoire de Physique Subatomique et de Cosmologie, Universite Joseph Fourier Grenoble 1, CNRS/IN2P3, Institut Polytechnique de Grenoble, 53, rue des Martyrs, Grenoble (France); Lee, M H; Lutz, L [University of Maryland, College Park MD 20742 (United States); Menchaca-Rocha, A [Instituto de Fisica, UNAM, A.P. 20-364, 01000 Mexico DF (Mexico); Perie, J N, E-mail: olivier.bourrion@lpsc.in2p3.fr [Universite de Toulouse, INSA, UPS, Mines Albi, ISAE, ICA (Institut Clement Ader), 133, avenue de Rangueil, F-31077 Toulouse (France)

    2011-06-15

    A proximity focusing Cherenkov imager called CHERCAM, has been built for the charge measurement of nuclear cosmic rays with the CREAM instrument. It consists of a silica aerogel radiator plane across from a detector plane equipped with 1,600 1'' diameter photomultipliers. The two planes are separated by a ring expansion gap. The Cherenkov light yield is proportional to the charge squared of the incident particle. The expected relative light collection accuracy is in the few percents range. It leads to an expected single element separation over the range of nuclear charge Z of main interest 1 {<=} Z{approx}<26. CHERCAM is designed to fly with the CREAM balloon experiment. The design of the instrument and the implemented technical solutions allowing its safe operation in high altitude conditions (radiations, low pressure, cold) are presented.

  9. Monte Carlo Studies of medium-size telescope designs for the Cherenkov Telescope Array

    CERN Document Server

    Wood, M; Dumm, J; Funk, S

    2015-01-01

    We present studies for optimizing the next generation of ground-based imaging atmospheric Cherenkov telescopes (IACTs). Results focus on mid-sized telescopes (MSTs) for CTA, detecting very high energy gamma rays in the energy range from a few hundred GeV to a few tens of TeV. We describe a novel, flexible detector Monte Carlo package, FAST (FAst Simulation for imaging air cherenkov Telescopes), that we use to simulate different array and telescope designs. The simulation is somewhat simplified to allow for efficient exploration over a large telescope design parameter space. We investigate a wide range of telescope performance parameters including optical resolution, camera pixel size, and light collection area. In order to ensure a comparison of the arrays at their maximum sensitivity, we analyze the simulations with the most sensitive techniques used in the field, such as maximum likelihood template reconstruction and boosted decision trees for background rejection. Choosing telescope design parameters repre...

  10. The calibration system of the GERDA muon veto Cherenkov detector

    Energy Technology Data Exchange (ETDEWEB)

    Ritter, Florian, E-mail: ritter@pit.physik.uni-tuebingen.d [Kepler Centre for Astro and Particle Physics, Universitaet Tuebingen, Tuebingen (Germany); Lubsandorzhiev, Bayarto [Kepler Centre for Astro and Particle Physics, Universitaet Tuebingen, Tuebingen (Germany); Institute for Nuclear Research of RAS, Moscow (Russian Federation); Freund, Kai; Grabmayr, Peter; Jochum, Josef; Knapp, Markus; Meierhofer, Georg [Kepler Centre for Astro and Particle Physics, Universitaet Tuebingen, Tuebingen (Germany); Shaibonov, Bator [Institute for Nuclear Research of RAS, Moscow (Russian Federation)

    2010-05-21

    The GERDA experiment searches for neutrinoless double beta decay (0{nu}{beta}{beta}). To achieve a sensitivity of 10{sup -3}counts/(keVkgy) or better within a specific region of interest (ROI), a good background identification is needed. Therefore GERDA is located in the LNGS (Laboratori Nationali del Gran Sasso) underground facility. In addition to the good rejection of cosmic muons due to the surrounding bedrocks, a dual muon veto system has to be used. For calibration and monitoring of the muon veto, two separate systems have been developed.

  11. Cherenkov light imaging in astro-particle physics

    Energy Technology Data Exchange (ETDEWEB)

    Mirzoyan, Razmik, E-mail: Razmik.Mirzoyan@mpp.mpg.de

    2014-12-01

    Cherenkov light emission plays a key role in contemporary science; it is widely used in high energy, nuclear, and numerous astro-particle physics experiments. Most astro-particle physics experiments are based on the detection of light, and a vast majority of them on the measurement of Cherenkov light. Cherenkov light emission is measured in gases (used in air-Cherenkov technique), in water (for example, neutrino experiments BAIKAL, Super-Kamiokande, NESTOR, ANTARES, future KM3NeT; cosmic and γ-ray experiments Milagro, HAWC, AUGER) and in ice (IceCube). In this report our goal is not limited to simply listing the multitude of experiments that are based on using Cherenkov emission, but we will clarify the reasons making this emission so important and so frequently used. For completeness we will first give a short historical overview on the discovery and evolution of Cherenkov emission and then we will dwell on its main features and numerous applications in astro-particle physics experiments. - Highlights: • We explain why Cherenkov emission is so important and why it is so widely used. • A brief historical excursion is made to the very beginning of Cherenkov emission. • Imaging of the Cherenkov light emission is discussed in a great detail. • The principle of Cherenkov light imaging in diverse experiments is the same.

  12. Development of new photon detection device for Cherenkov and fluorescence radiation

    Directory of Open Access Journals (Sweden)

    Tinti A.

    2013-06-01

    Full Text Available Recent progress on the development of a new solid state detector allowed the use of finely pixelled photocathodes obtained from silicon semiconductors. SiPM detectors seem to be an ideal tool for the detection of Cherenkov and fluorescence light in spite of their not yet resolved criticism for operating temperature and intrinsic noise. The main disadvantage of SiPM in this case is the poor sensitivity in the wavelength range 300-400 nm, where the Cherenkov light and fluorescence radiation are generated. We report on the possibility to realize a new kind of pixelled photodetector based on the use of silicon substrate with carbon nanotube compounds, more sensitive to the near UV radiation. Also if at the very beginning, the development of such detector appears very promising and useful for astroparticle physics, both in the ground based arrays and in the space experiments. The detectors are ready to be operated in conditions of measurements without signal amplification.

  13. Characterization of coherent Cherenkov radiation source

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, A.V.

    2015-01-21

    Engineering formulae for calculation of peak, and spectral brightness of resonant long-range wakefield extractor are given. It is shown that the brightness is dominated by beam density in the slow wave structure and antenna gain of the outcoupling. Far field radiation patterns and brightness of circular and high aspect ratio planar radiators are compared. A possibility to approach diffraction limited brightness is demonstrated. The role of group velocity in designing of the Cherenkov source is analyzed. The approach can be applied for design and characterization of various structure-dominated sources (e.g., wakefield extractors with gratings or dielectrics, or FEL-Cherenkov combined sources) radiating into a free space using an antenna (in microwave to sub-mm wave regions). The high group velocity structures can be also effective as energy dechirpers and for diagnostics of microbunched relativistic electron beams.

  14. Performance of the STACEE Atmospheric Cherenkov Telescope

    CERN Document Server

    Williams, D A; Boone, L M; Chantell, M C; Conner, Z; Covault, C E; Dragovan, M; Fortin, P; Gingrich, D M; Gregorich, D T; Hanna, D S; Mohanty, G B; Mukherjee, R; Ong, R A; Oser, S M; Ragan, K; Scalzo, R A; Schütte, D R; Theoret, C G; Tümer, T O; Vincent, F; Zweerink, J A

    2000-01-01

    The Solar Tower Atmospheric Cherenkov Effect Experiment (STACEE) is located at the National Solar Thermal Test Facility of Sandia National Laboratories in Albuquerque, New Mexico, USA. The field of solar tracking mirrors (heliostats) around a central receiver tower is used to direct Cherenkov light from atmospheric showers onto secondary mirrors on the tower, which in turn image the light onto cameras of photomultiplier tubes. The STACEE Collaboration has previously reported a detection of the Crab Nebula with approximately 7 standard deviation significance, using 32 heliostats (STACEE-32). This result demonstrates both the viability of the technique and the suitability of the site. We are in the process of completing an upgrade to 48 heliostats (STACEE-48) en route to an eventual configuration using 64 heliostats (STACEE-64) in early 2001. In this paper, we summarize the results obtained on the sensitivity of STACEE-32 and our expectations for STACEE-48 and STACEE-64.

  15. Mirror Development for the Cherenkov Telescope Array

    CERN Document Server

    Förster, A; Baba, H; Bähr, J; Bonardi, A; Bonnoli, G; Brun, P; Canestrari, R; Chadwick, P; Chikawa, M; Carton, P -H; De Souza, V; Dipold, J; Doro, M; Durand, D; Dyrda, M; Giro, E; Glicenstein, J -F; Hanabata, Y; Hayashida, M; Hrabovski, M; Jeanney, C; Kagaya, M; Katagiri, H; Lessio, L; MANDAT, D; Mariotti, M; Medina, C; Michałowski, J; Micolon, P; Nakajima, D; Niemiec, J; Nozato, A; Palatka, M; Pareschi, G; Pech, M; Peyaud, B; Pühlhofer, G; Rataj, M; Rodeghiero, G; Rojas, G; Rousselle, J; Sakonaka, R; Schovanek, P; Seweryn, K; Schultz, C; Shu, S; Stinzing, F; Stodulski, M; Teshima, M; Travniczek, P; Van Eldik, C; Vassiliev, V; Wiśniewski, Ł; Wörnlein, A; Yoshida, T

    2013-01-01

    The Cherenkov Telescope Array (CTA) is a planned observatory for very-high energy gamma-ray astronomy. It will consist of several tens of telescopes of different sizes, with a total mirror area of up to 10,000 square meters. Most mirrors of current installations are either polished glass mirrors or diamond-turned aluminium mirrors, both labour intensive technologies. For CTA, several new technologies for a fast and cost-efficient production of light-weight and reliable mirror substrates have been developed and industrial pre-production has started for most of them. In addition, new or improved aluminium-based and dielectric surface coatings have been developed to increase the reflectance over the lifetime of the mirrors compared to those of current Cherenkov telescope instruments.

  16. Bokeh Mirror Alignment for Cherenkov Telescopes

    CERN Document Server

    Ahnen, M L; Balbo, M; Bergmann, M; Biland, A; Blank, M; Bretz, T; Bruegge, K A; Buss, J; Domke, M; Dorner, D; Einecke, S; Hempfling, C; Hildebrand, D; Hughes, G; Lustermann, W; Mannheim, K; Mueller, S A; Neise, D; Neronov, A; Noethe, M; Overkemping, A -K; Paravac, A; Pauss, F; Rhode, W; Shukla, A; Temme, F; Thaele, J; Toscano, S; Vogler, P; Walter, R; Wilbert, A

    2016-01-01

    Imaging Atmospheric Cherenkov Telescopes (IACTs) need imaging optics with large apertures and high image intensities to map the faint Cherenkov light emitted from cosmic ray air showers onto their image sensors. Segmented reflectors fulfill these needs, and composed from mass production mirror facets they are inexpensive and lightweight. However, as the overall image is a superposition of the individual facet images, alignment remains a challenge. Here we present a simple, yet extendable method, to align a segmented reflector using its Bokeh. Bokeh alignment does not need a star or good weather nights but can be done even during daytime. Bokeh alignment optimizes the facet orientations by comparing the segmented reflectors Bokeh to a predefined template. The optimal Bokeh template is highly constricted by the reflector's aperture and is easy accessible. The Bokeh is observed using the out of focus image of a near by point like light source in a distance of about 10 focal lengths. We introduce Bokeh alignment ...

  17. Performance of the STACEE Atmospheric Cherenkov Telescope

    Science.gov (United States)

    Williams, D. A.; Bhattacharya, D.; Boone, L. M.; Chantell, M. C.; Conner, Z.; Covault, C. E.; Dragovan, M.; Fortin, P.; Gingrich, D.; Gregorich, D. T.; Hanna, D. S.; Mohanty, G.; Mukherjee, R.; Ong, R. A.; Oser, S.; Ragan, K.; Scalzo, R. A.; Schuette, D. R.; Théoret, C. G.; Tümer, T. O.; Vincent, F.; Zweerink, J. A.

    2001-04-01

    The Solar Tower Atmospheric Cherenkov Effect Experiment (STACEE) is located at the National Solar Thermal Test Facility of Sandia National Laboratories in Albuquerque, New Mexico, USA. The field of solar tracking mirrors (heliostats) around a central receiver tower is used to direct Cherenkov light from atmospheric showers onto secondary mirrors on the tower, which in turn image the light onto cameras of photomultiplier tubes. The STACEE Collaboration has previously reported a detection of the Crab Nebula with approximately 7 standard deviation significance, using 32 heliostats (STACEE-32). This result demonstrates both the viability of the technique and the suitability of the site. We are in the process of completing an upgrade to 48 heliostats (STACEE-48) en route to an eventual configuration using 64 heliostats (STACEE-64) in early 2001. In this paper, we summarize the results obtained on the sensitivity of STACEE-32 and our expectations for STACEE-48 and STACEE-64. .

  18. Recent progress in silica aerogel Cherenkov radiator

    CERN Document Server

    Tabata, Makoto; Kawai, Hideyuki; Kubo, Masato; Sato, Takeshi

    2012-01-01

    In this paper, we present recent progress in the development of hydrophobic silica aerogel as a Cherenkov radiator. In addition to the conventional method, the recently developed pin-drying method for producing high-refractive-index aerogels with high transparency was studied in detail. Optical qualities and large tile handling for crack-free aerogels were investigated. Sufficient photons were detected from high-performance aerogels in a beam test.

  19. Bokeh mirror alignment for Cherenkov telescopes

    Science.gov (United States)

    Ahnen, M. L.; Baack, D.; Balbo, M.; Bergmann, M.; Biland, A.; Blank, M.; Bretz, T.; Bruegge, K. A.; Buss, J.; Domke, M.; Dorner, D.; Einecke, S.; Hempfling, C.; Hildebrand, D.; Hughes, G.; Lustermann, W.; Mannheim, K.; Mueller, S. A.; Neise, D.; Neronov, A.; Noethe, M.; Overkemping, A.-K.; Paravac, A.; Pauss, F.; Rhode, W.; Shukla, A.; Temme, F.; Thaele, J.; Toscano, S.; Vogler, P.; Walter, R.; Wilbert, A.

    2016-09-01

    Imaging Atmospheric Cherenkov Telescopes (IACTs) need imaging optics with large apertures and high image intensities to map the faint Cherenkov light emitted from cosmic ray air showers onto their image sensors. Segmented reflectors fulfill these needs, and composed from mass production mirror facets they are inexpensive and lightweight. However, as the overall image is a superposition of the individual facet images, alignment remains a challenge. Here we present a simple, yet extendable method, to align a segmented reflector using its Bokeh. Bokeh alig nment does not need a star or good weather nights but can be done even during daytime. Bokeh alignment optimizes the facet orientations by comparing the segmented reflectors Bokeh to a predefined template. The optimal Bokeh template is highly constricted by the reflector's aperture and is easy accessible. The Bokeh is observed using the out of focus image of a near by point like light source in a distance of about 10 focal lengths. We introduce Bokeh alignment on segmented reflectors and demonstrate it on the First Geiger-mode Avalanche Cherenkov Telescope (FACT) on La Palma, Spain.

  20. The STACEE Ground-Based Gamma-Ray Detector

    CERN Document Server

    Gingrich, D M; Bramel, D; Carson, J; Covault, C E; Fortin, P; Hanna, D S; Hinton, J A; Jarvis, A; Kildea, J; Lindner, T; Müller, C; Mukherjee, R; Ong, R A; Ragan, K; Scalzo, R A; Theoret, C G; Williams, D A; Zweerink, J A

    2005-01-01

    We describe the design and performance of the Solar Tower Atmospheric Cherenkov Effect Experiment (STACEE) in its complete configuration. STACEE uses the heliostats of a solar energy research facility to collect and focus the Cherenkov photons produced in gamma-ray induced air showers. The light is concentrated onto an array of photomultiplier tubes located near the top of a tower. The large Cherenkov photon collection area of STACEE results in a gamma-ray energy threshold below that of previous ground-based detectors. STACEE is being used to observe pulsars, supernova remnants, active galactic nuclei, and gamma-ray bursts.

  1. Field test: first detection of Cherenkov light from air showers with Geiger APDs

    Energy Technology Data Exchange (ETDEWEB)

    Otte, N. [Max-Planck-Inst. fuer Physik, Muenchen (Germany); Biland, A.; Ilia, B.; Felicitas, P.; Ulf, R. [Eidgenoessische Technische Hochschule, Zuerich (Switzerland); Eckart, L. [Max-Planck-Inst. fuer Physik, Muenchen (Germany); Eidgenoessische Technische Hochschule, Zuerich (Switzerland); Dieter, R. [Paul Scherrer Inst., Villigen (Switzerland)

    2007-07-01

    G-APDs are novel semiconductor photon-detectors which offer several advantages compared to conventional photomultiplier tubes in the field of air shower detection. Folded with the Cherenkov spectrum the response of G-APDs is up to a factor of three higher if compared with classical photomultipliers. Moreover they offer high gain ({proportional_to} 10{sup 5}.. 10{sup 6}) at low operation voltages (< 100 V). Under operation they are insensible to excessive and prolonged exposure to light and are mechanical robust. Dark count rates of some G-APDs are below the level of light coming from the night sky. Furthermore G-APDs can be mass-produced which allows to considerably reduce the costs of these sensors. According to the present state of the development of G-APD they promise to be a major progress for {gamma}-ray astronomy. Here we report on first-time tests of the detection of Cherenkov light from air showers with G-APD. We discuss first test results and the advantages and problems of G-APDs in Cherenkov telescopes. (orig.)

  2. Ground detectors for the study of cosmic ray showers

    Science.gov (United States)

    Salazar, H.; Villasenor, L.

    2008-06-01

    We describe the work that we have done over the last decade to design and construct instruments to measure properties of cosmic rays in Mexico. We describe the detection of decaying and crossing muons in a water Cherenkov detector and discuss an application of these results to calibrate water Cherenkov detectors. We also describe a technique to separate isolated isolated muons and electrons in water Cherenkov detector. Next we describe the design and performance of a hybrid extensive air shower detector array built on the Campus of the University of Puebla (19°N, 90°W, 800 g/cm2) to measure the energy, arrival direction and composition of primary cosmic rays with energies around 1 PeV.

  3. Ground detectors for the study of cosmic ray showers

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, H [Facultad de Ciencias Fisico-Matematicas, BUAP, Puebla, Pue., 72000 (Mexico); Villasenor, L [Instituto de Fisica y Matematicas, UMSNH, Morelia, Michoacan, 58040 (Mexico)], E-mail: villasen@ifm.umich.mx

    2008-06-01

    We describe the work that we have done over the last decade to design and construct instruments to measure properties of cosmic rays in Mexico. We describe the detection of decaying and crossing muons in a water Cherenkov detector and discuss an application of these results to calibrate water Cherenkov detectors. We also describe a technique to separate isolated isolated muons and electrons in water Cherenkov detector. Next we describe the design and performance of a hybrid extensive air shower detector array built on the Campus of the University of Puebla (19 deg. N, 90 deg. W, 800 g/cm{sup 2}) to measure the energy, arrival direction and composition of primary cosmic rays with energies around 1 PeV.

  4. Detection of Shielded Special Nuclear Material With a Cherenkov-Based Transmission Imaging System

    Science.gov (United States)

    Rose, Paul; Erickson, Anna; Mayer, Michael; Jovanovic, Igor

    2015-10-01

    Detection of shielded special nuclear material, SSNM, while in transit, offers a unique challenge. Typical cargo imaging systems are Bremsstrahlung-based and cause an abundance of unnecessary signal in the detectors and doses to the cargo contents and surroundings. Active interrogation with dual monoenergetic photons can unveil the illicit material when coupled with a high-contrast imaging system while imparting significantly less dose to the contents. Cherenkov detectors offer speed, resilience, inherent energy threshold rejection, directionality and scalability beyond the capability of most scintillators. High energy resolution is not a priority when using two well separated gamma rays, 4.4 and 15.1 MeV, generated from low energy nuclear reactions such as 11B(d,n- γ)12C. These gamma rays offer a measure of the effective atomic number, Z, of the cargo by taking advantage of the large difference in photon interaction cross sections, Compton scattering and pair production. This imaging system will be coupled to neutron detectors to provide unique signature of SNM by monitoring delayed neutrons. Our experiments confirm that the Cherenkov imaging system can be used with the monoenergetic source to relate transmission and atomic number of the scanned material.

  5. End-view of the DELPHI detector

    CERN Multimedia

    1996-01-01

    End-view of the 10-m diameter DELPHI detector at CERN's LEP electron-positron collider from 1989 to 2000. Its concentric modules, including a pioneer large-scale application of the Ring Imaging Cherenkov technique to differentiate between all the various secondary particles, ensure high precision and 'granularity'.

  6. A disc-DIRC-Detector for WASA at COSY as a test detector for PANDA rate at FAIR

    Energy Technology Data Exchange (ETDEWEB)

    Doroshkevich, Evgueni [Physikalisches Institut, Universitaet Tuebingen (Germany)

    2010-07-01

    For a precise measurement of the velocity of highly relativistic particles the detection of Cherenkov light is very attractive. Detectors based on the Detection of Internally Reflected Cherenkov Light (DIRC) - first built and used in the BaBar experiment - are also planned to be used in the PANDA detector at FAIR, both in form of a barrel-DIRC and in form of a disc-DIRC. In both cases the Cherenkov rings are reconstructed from the internally reflected Cherenkov light deflected into position sensitive detectors. For the WASA Forward Detector setup a Disc-DIRC is constructed, which serves both as a test module for PANDA and an important upgrade of the WASA detector. For an optimal performance at WASA the Disc-DIRC is tilted by 20 out of the vertical plane. The internally reflected Cherenkov light will be guided to multi-anode photomultipliers by focussing light guides. Both Disc-DIRC and focussing light guides will be made of plexiglass. Design, performance and time line of construction and implementation are discussed.

  7. Recent results on aerogel development for use in Cherenkov counters

    Energy Technology Data Exchange (ETDEWEB)

    Danilyuk, A.F. E-mail: danilyuk@catalysis.nsk.su; Kirillov, V.L.; Savelieva, M.D.; Bobrovnikov, V.S.; Buzykaev, A.R.; Kravchenko, E.A.; Lavrov, A.V.; Onuchin, A.P

    2002-11-21

    Synthesis of silica aerogel for Cherenkov counters is being studied for more than 10 years at the Boreskov Institute of Catalysis in collaboration with the Budker Institute of Nuclear Physics. Index of refraction, light scattering length and light absorption length are optical characteristics which determine the quality of aerogel Cherenkov counter. These parameters were measured for the aerogel produced. The results are presented.

  8. Recent results on aerogel development for use in Cherenkov counters

    CERN Document Server

    Danilyuk, A F; Savelieva, M D; Bobrovnikov, V S; Buzykaev, A R; Kravchenko, E A; Lavrov, A V; Onuchin, A P

    2002-01-01

    Synthesis of silica aerogel for Cherenkov counters is being studied for more than 10 years at the Boreskov Institute of Catalysis in collaboration with the Budker Institute of Nuclear Physics. Index of refraction, light scattering length and light absorption length are optical characteristics which determine the quality of aerogel Cherenkov counter. These parameters were measured for the aerogel produced. The results are presented.

  9. Camera Development for the Cherenkov Telescope Array

    Science.gov (United States)

    Moncada, Roberto Jose

    2017-01-01

    With the Cherenkov Telescope Array (CTA), the very-high-energy gamma-ray universe, between 30 GeV and 300 TeV, will be probed at an unprecedented resolution, allowing deeper studies of known gamma-ray emitters and the possible discovery of new ones. This exciting project could also confirm the particle nature of dark matter by looking for the gamma rays produced by self-annihilating weakly interacting massive particles (WIMPs). The telescopes will use the imaging atmospheric Cherenkov technique (IACT) to record Cherenkov photons that are produced by the gamma-ray induced extensive air shower. One telescope design features dual-mirror Schwarzschild-Couder (SC) optics that allows the light to be finely focused on the high-resolution silicon photomultipliers of the camera modules starting from a 9.5-meter primary mirror. Each camera module will consist of a focal plane module and front-end electronics, and will have four TeV Array Readout with GSa/s Sampling and Event Trigger (TARGET) chips, giving them 64 parallel input channels. The TARGET chip has a self-trigger functionality for readout that can be used in higher logic across camera modules as well as across individual telescopes, which will each have 177 camera modules. There will be two sites, one in the northern and the other in the southern hemisphere, for full sky coverage, each spanning at least one square kilometer. A prototype SC telescope is currently under construction at the Fred Lawrence Whipple Observatory in Arizona. This work was supported by the National Science Foundation's REU program through NSF award AST-1560016.

  10. The Cherenkov Telescope Array Large Size Telescope

    CERN Document Server

    Ambrosi, G; Baba, H; Bamba, A; Barceló, M; de Almeida, U Barres; Barrio, J A; Bigas, O Blanch; Boix, J; Brunetti, L; Carmona, E; Chabanne, E; Chikawa, M; Colin, P; Conteras, J L; Cortina, J; Dazzi, F; Deangelis, A; Deleglise, G; Delgado, C; Díaz, C; Dubois, F; Fiasson, A; Fink, D; Fouque, N; Freixas, L; Fruck, C; Gadola, A; García, R; Gascon, D; Geffroy, N; Giglietto, N; Giordano, F; Grañena, F; Gunji, S; Hagiwara, R; Hamer, N; Hanabata, Y; Hassan, T; Hatanaka, K; Haubold, T; Hayashida, M; Hermel, R; Herranz, D; Hirotani, K; Inoue, S; Inoue, Y; Ioka, K; Jablonski, C; Kagaya, M; Katagiri, H; Kishimoto, T; Kodani, K; Kohri, K; Konno, Y; Koyama, S; Kubo, H; Kushida, J; Lamanna, G; Flour, T Le; López-Moya, M; López, R; Lorenz, E; Majumdar, P; Manalaysay, A; Mariotti, M; Martínez, G; Martínez, M; Mazin, D; Miranda, J M; Mirzoyan, R; Monteiro, I; Moralejo, A; Murase, K; Nagataki, S; Nakajima, D; Nakamori, T; Nishijima, K; Noda, K; Nozato, A; Ohira, Y; Ohishi, M; Ohoka, H; Okumura, A; Orito, R; Panazol, J L; Paneque, D; Paoletti, R; Paredes, J M; Pauletta, G; Podkladkin, S; Prast, J; Rando, R; Reimann, O; Ribó, M; Rosier-Lees, S; Saito, K; Saito, T; Saito, Y; Sakaki, N; Sakonaka, R; Sanuy, A; Sasaki, H; Sawada, M; Scalzotto, V; Schultz, S; Schweizer, T; Shibata, T; Shu, S; Sieiro, J; Stamatescu, V; Steiner, S; Straumann, U; Sugawara, R; Tajima, H; Takami, H; Tanaka, S; Tanaka, M; Tejedor, L A; Terada, Y; Teshima, M; Totani, T; Ueno, H; Umehara, K; Vollhardt, A; Wagner, R; Wetteskind, H; Yamamoto, T; Yamazaki, R; Yoshida, A; Yoshida, T; Yoshikoshi, T

    2013-01-01

    The two arrays of the Very High Energy gamma-ray observatory Cherenkov Telescope Array (CTA) will include four Large Size Telescopes (LSTs) each with a 23 m diameter dish and 28 m focal distance. These telescopes will enable CTA to achieve a low-energy threshold of 20 GeV, which is critical for important studies in astrophysics, astroparticle physics and cosmology. This work presents the key specifications and performance of the current LST design in the light of the CTA scientific objectives.

  11. The AMS-01 Aerogel Threshold Cherenkov counter

    Energy Technology Data Exchange (ETDEWEB)

    Barancourt, D.; Barao, F.; Barbier, G.; Barreira, G.; Buenerd, M.; Castellini, G.; Choumilov, E.; Favier, J.; Fouque, N.; Gougas, A.; Hermel, V.; Kossakowski, R.; Laborie, G.; Laurenti, G.; Lee, S.-C.; Mayet, F. E-mail: frederic.mayet@isn.in2p3.fr; Meillon, B.; Oyang, Y.-T.; Plyaskin, V.; Pojidaev, V.; Rossin, C.; Santos, D.; Vezzu, F.; Vialle, J.P

    2001-06-11

    The Alpha Magnetic Spectrometer in a precursor version (AMS-01), was flown in June 1998 on a 51.6 deg. orbit and at altitudes ranging between 320 and 390 km, on board of the space shuttle Discovery (flight STS-91). AMS-01 included an Aerogel Threshold Cherenkov counter (ATC) to separate p-bar from e{sup -} and e{sup +} from p, for momenta below 3.5 GeV/c. This paper presents a description of the ATC counter and reports on its performances during the flight STS-91.

  12. The AMS-01 Aerogel Threshold Cherenkov counter

    CERN Document Server

    Barancourt, D; Barbier, G; Barreira, G; Buénerd, M; Castellini, G; Choumilov, E; Favier, Jean; Fouque, N; Gougas, Andreas; Hermel, V; Kossakowski, R; Laborie, G; Laurenti, G; Lee, S C; Mayet, F; Meillon, B; Oyang, J Y T; Plyaskin, V; Pozhidaev, V; Rossin, C; Santos, D; Vezzu, F; Vialle, J P

    2001-01-01

    The Alpha Magnetic Spectrometer in a precursor version (AMS-01), was flown in June 1998 on a 51.6 degrees orbit and at altitudes ranging between 320 and 390 km, on board of the space shuttle Discovery (flight STS-91). AMS-01 included an Aerogel Threshold Cherenkov counter (ATC) to separate antiprotons from electrons and positrons from protons, for momenta below 3.5 GeV/c. This paper presents a description of the ATC counter and reports on its performances during the flight STS-91.

  13. Atmospheric Cherenkov Gamma-ray Telescopes

    CERN Document Server

    Holder, Jamie

    2015-01-01

    The stereoscopic imaging atmospheric Cherenkov technique, developed in the 1980s and 1990s, is now used by a number of existing and planned gamma-ray observatories around the world. It provides the most sensitive view of the very high energy gamma-ray sky (above 30 GeV), coupled with relatively good angular and spectral resolution over a wide field-of-view. This Chapter summarizes the details of the technique, including descriptions of the telescope optical systems and cameras, as well as the most common approaches to data analysis and gamma-ray reconstruction.

  14. Latest news from the High Altitude Water Cherenkov Observatory

    Science.gov (United States)

    González Muñoz, A.; HAWC Collaboration

    2016-07-01

    The High Altitude Water Cherenkov Observatory is an air shower detector designed to study very-high-energy gamma rays (˜ 100 GeV to ˜ 100 TeV). It is located in the Pico de Orizaba National Park, Mexico, at an elevation of 4100 m. HAWC started operations since August 2013 with 111 tanks and in April of 2015 the 300 tanks array was completed. HAWC's unique capabilities, with a field of view of ˜ 2 sr and a high duty cycle of 5%, allow it to survey 2/3 of the sky every day. These features makes HAWC an excellent instrument for searching new TeV sources and for the detection of transient events, like gamma-ray bursts. Moreover, HAWC provides almost continuous monitoring of already known sources with variable gamma-ray fluxes in most of the northern and part of the southern sky. These observations will bring new information about the acceleration processes that take place in astrophysical environments. In this contribution, some of the latest scientific results of the observatory will be presented.

  15. Particle Identification Using a Ring Imaging Cherenkov Counter

    Science.gov (United States)

    Goodwill, Justin; Benmokthar, Fatiha

    2016-09-01

    The installation of a Ring Imaging Cherenkov counter (RICH) on the CLAS12 spectrometer in Hall B of Jefferson Lab will aid in particle identification, specifically with regard to the separation between protons, pions, kaons. The RICH functions by detecting a ring of radiation that is given off by particles moving faster than the speed of light in a medium through the use of multi-anode photomultiplier tubes (MAPMTs). Because the size of the ring is dependent on the velocity of the particles, one can separate the incoming charged particles. With 391 MAPMTs being used in the specific design at Jefferson Lab, sophisticated electronic systems are needed to achieve complete data acquisition and ensure the safe operation of RICH. To monitor these electronic systems, the slow control system uses a compilation of graphical user interfaces (GUIs) that communicates and, if necessary, changes certain process variables such as the high voltage going to the MAPMTs and the temperature of the system. My actual project focuses on the development of an efficient and reliable slow control system for this detector as well as a java based analyzer for offline data analysis.

  16. The RICH2 detector took its place in the LHCb experiment

    CERN Multimedia

    2005-01-01

    The LHCb's RICH2 detector, the larger of two Ring Imaging Cherenkov detectors, has been successfully installed at the site of the LHCb experiment. A delicate and complex operation that had taken place during night and day finished on Saturday 19th November at 6 pm, when the RICH2 detector took its place in the LHCb experiment.

  17. Roughness tolerances for Cherenkov telescope mirrors

    CERN Document Server

    Tayabaly, K; Canestrari, R; Bonnoli, G; Lavagna, M; Pareschi, G

    2016-01-01

    The Cherenkov Telescope Array (CTA) is a forthcoming international ground-based observatory for very high-energy gamma rays. Its goal is to reach sensitivity five to ten times better than existing Cherenkov telescopes such as VERITAS, H.E.S.S. or MAGIC and extend the range of observation to energies down to few tens of GeV and beyond 100 TeV. To achieve this goal, an array of about 100 telescopes is required, meaning a total reflective surface of several thousands of square meters. Thence, the optimal technology used for CTA mirrors manufacture should be both low-cost (~1000 euros/m2) and allow high optical performances over the 300-550 nm wavelength range. More exactly, a reflectivity higher than 85% and a PSF (Point Spread Function) diameter smaller than 1 mrad. Surface roughness can significantly contribute to PSF broadening and limit telescope performances. Fortunately, manufacturing techniques for mirrors are now available to keep the optical scattering well below the geometrically-predictable effect of ...

  18. The RICH detectors of the LHCb experiment

    CERN Document Server

    Perego, D L

    2009-01-01

    The status of the Ring Imaging Cherenkov (RICH) system of the LHCb experiment is presented. The commissioning of both RICH detectors is in an advanced phase and they are ready to take data at the start–up of the Large Hadron Collider. The detectors provide essential contributions to the LHCb physics program. The expected performance of the RICH system, the pattern recognition and the particle identification is discussed.

  19. The next generation Cherenkov Telescope Array observatory: CTA

    Energy Technology Data Exchange (ETDEWEB)

    Vercellone, S., E-mail: stefano@ifc.inaf.it

    2014-12-01

    The Cherenkov Telescope Array (CTA) is a large collaborative effort aimed at the design and operation of an observatory dedicated to the very high-energy gamma-ray astrophysics in the energy range 30 GeV–100 TeV, which will improve by about one order of magnitude the sensitivity with respect to the current major arrays (H.E.S.S., MAGIC, and VERITAS). In order to achieve such improved performance, for both the northern and southern CTA sites, four units of 23 m diameter Large Size Telescopes (LSTs) will be deployed close to the centre of the array with telescopes separated by about 100 m. A larger number (about 25 units) of 12 m Medium Size Telescopes (MSTs, separated by about 150 m), will cover a larger area. The southern site will also include up to 24 Schwarzschild–Couder dual-mirror medium-size Telescopes (SCTs) with the primary mirror diameter of 9.5 m. Above a few TeV, the Cherenkov light intensity is such that showers can be detected even well outside the light pool by telescopes significantly smaller than the MSTs. To achieve the required sensitivity at high energies, a huge area on the ground needs to be covered by Small Size Telescopes (SSTs) with a field of view of about 10° and an angular resolution of about 0.2°, making the dual-mirror configuration very effective. The SST sub-array will be composed of 50–70 telescopes with a mirror area of about 5–10 m{sup 2} and about 300 m spacing, distributed across an area of about 10 km{sup 2}. In this presentation we will focus on the innovative solution for the optical design of the medium and small size telescopes based on a dual-mirror configuration. This layout will allow us to reduce the dimension and the weight of the camera at the focal plane of the telescope, to adopt Silicon-based photo-multipliers as light detectors thanks to the reduced plate-scale, and to have an optimal imaging resolution on a wide field of view.

  20. The next generation Cherenkov Telescope Array observatory: CTA

    Science.gov (United States)

    Vercellone, S.

    2014-12-01

    The Cherenkov Telescope Array (CTA) is a large collaborative effort aimed at the design and operation of an observatory dedicated to the very high-energy gamma-ray astrophysics in the energy range 30 GeV-100 TeV, which will improve by about one order of magnitude the sensitivity with respect to the current major arrays (H.E.S.S., MAGIC, and VERITAS). In order to achieve such improved performance, for both the northern and southern CTA sites, four units of 23 m diameter Large Size Telescopes (LSTs) will be deployed close to the centre of the array with telescopes separated by about 100 m. A larger number (about 25 units) of 12 m Medium Size Telescopes (MSTs, separated by about 150 m), will cover a larger area. The southern site will also include up to 24 Schwarzschild-Couder dual-mirror medium-size Telescopes (SCTs) with the primary mirror diameter of 9.5 m. Above a few TeV, the Cherenkov light intensity is such that showers can be detected even well outside the light pool by telescopes significantly smaller than the MSTs. To achieve the required sensitivity at high energies, a huge area on the ground needs to be covered by Small Size Telescopes (SSTs) with a field of view of about 10° and an angular resolution of about 0.2°, making the dual-mirror configuration very effective. The SST sub-array will be composed of 50-70 telescopes with a mirror area of about 5-10 m2 and about 300 m spacing, distributed across an area of about 10 km2. In this presentation we will focus on the innovative solution for the optical design of the medium and small size telescopes based on a dual-mirror configuration. This layout will allow us to reduce the dimension and the weight of the camera at the focal plane of the telescope, to adopt Silicon-based photo-multipliers as light detectors thanks to the reduced plate-scale, and to have an optimal imaging resolution on a wide field of view.

  1. The design and performance of a prototype water Cherenkov optical time-projection chamber

    CERN Document Server

    Oberla, E

    2015-01-01

    A first experimental test of tracking relativistic charged particles by `drifting' Cherenkov photons in a water-based optical time-projection chamber (OTPC) has been performed at the Fermilab Test Beam Facility. The prototype OTPC detector consists of a 77~cm long, 28~cm diameter, 40~kg cylindrical water mass instrumented with a combination of commercial $5.1\\times5.1$~cm$^2$ micro-channel plate photo-multipliers (MCP-PMT) and $6.7\\times6.7$~cm$^2$ mirrors. Five MCP-PMTs are installed in two columns along the OTPC cylinder in a small-angle stereo configuration. A mirror is mounted opposite each MCP-PMT on the far side of the detector cylinder, effectively doubling the photo-detection efficiency and providing a time-resolved image of the Cherenkov light on the opposing wall. Each MCP-PMT is coupled to an anode readout consisting of thirty 50 Ohm microstrips. A 180-channel data acquisition system digitizes the MCP-PMT signals on one end of the microstrips using the PSEC4 waveform sampling-and-digitizing chip op...

  2. On the possiblity of using vertically pointing Central Laser Facilities to calibrate the Cherenkov Telescope Array

    CERN Document Server

    Gaug, Markus

    2014-01-01

    A Central Laser Facility is a system composed of a laser placed at a certain distance from a light-detector array, emitting fast light pulses, typically in the vertical direction, with the aim to calibrate that array. During calibration runs, all detectors are pointed towards the same portion of the laser beam at a given altitude. Central Laser Facilities are used for various currently operating ultra-high-energy cosmic ray and imaging atmospheric Cherenkov telescope arrays. In view of the future Cherenkov Telescope Array, a similar device could provide a fast calibration of the whole installation at different wavelengths. The relative precision (i.e. each individual telescope with respect to the rest of the array is expected) to be better than 5%, while an absolute calibration should reach a precisions of 4-11%, if certain design requirements are met. Additionally, a preciser monitoring of the sensitivity of each telescope can be made on time-scales of days to years.

  3. Design of a Cherenkov telescope for the measurement of PCR composition above 1 PeV

    Directory of Open Access Journals (Sweden)

    Galkin V I

    2013-06-01

    Full Text Available The problem of PCR Composition at super high energies is far from being solved.EAS Cherenkov light spatial-angular distribution (CL SAD can yield important information on the primary mass. In order to use EAS CL SAD for the study of PCR composition one needs a set of imaging telescopes with the appropriate parameters supported by a dense net of fast optical detectors capable of measuring EAS Cherenkov light pulses. On the basis of full Monte-Carlo simulations the pixel size of imaging telescopes is optimized for a specific observation level ∼4km which is typical for the Eastern Pamir mountains. Another goal to be pursued by the new detector array is the search for ultra high energy gamma ray sources and this is where the imaging technique can help a lot. A simple criterion is introduced to recognize gamma-quanta against the proton background and its performance, once again analyzed using simulated events, sets certain limits to the pixel size.

  4. The Photodetector Plane of the 4m Davies Cotton Small Size Telescope for the Cherenkov Telescope Array

    CERN Document Server

    Boccone, V; Basili, A; Christov, A; della Volpe, M; Montaruli, T

    2013-01-01

    Photomultipliers (PMTs) are currently adopted for the photodetector plane of Imaging Atmospheric Cherenkov Telescopes (IACTs). Even though PMT quantum efficiency has improved impressively in the recent years, one of the main limitation for their application in the gamma-astronomy field - the impossibility to operate with moon light - still remains. As a matter of fact, the light excess would lead to significant and faster camera ageing. Solid state detectors, in particular Geiger-mode avalanche photo-diodes (G-APDs) represent a valuable alternative solution to overcome this limitation as demonstrated in the field by the FACT experiment (The First G- APD Cherenkov Telescope). They can be regarded as a more promising long term approach, which can be easily adopted for the new generation of cameras and for the Cherenkov Telescope Array (CTA). We describe here the Photo-Detector Plane (PDP) of the camera for the 4 m Davies Cotton CTA Small Size Telescopes, for which large area G-APD coupled to non-imaging light c...

  5. Monte Carlo simulation of the Cherenkov radiation emitted by TeO{sub 2} crystal when crossed by cosmic muons

    Energy Technology Data Exchange (ETDEWEB)

    Casali, N., E-mail: nicola.casali@gmail.com [Dipartimento di Scienze Fisiche e Chimiche, Università degli studi dell' Aquila, Coppito (AQ) (Italy); Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Gran Sasso, Assergi (AQ) (Italy); Bellini, F. [Sapienza Università di roma, P.le A. Moro 2, Roma (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Roma, P.le A. Moro 2, Roma (Italy); Dafinei, I. [Istituto Nazionale di Fisica Nucleare, Sezione di Roma, P.le A. Moro 2, Roma (Italy); Marafini, M. [Museo Storico della Fisisca e Centro Studi e Ricerche “Enrico Fermi“, Piazza del Viminale 1, Roma (Italy); Morganti, S.; Orio, F.; Pinci, D.; Vignati, M.; Voena, C. [Istituto Nazionale di Fisica Nucleare, Sezione di Roma, P.le A. Moro 2, Roma (Italy)

    2013-12-21

    TeO{sub 2} crystals are currently used as bolometric detectors in experiments searching for the neutrinoless double beta decay of {sup 130}Te. The extreme rarity of the studied signal forces the experiments to reach an ultra low background level. The main background source is represented by α particles emitted by radioactive contaminants placed in the materials that compose and surround the detector. Recent measurements show that a particle discrimination in TeO{sub 2} bolometers detecting the light emitted by β/γ particles is possible, opening the possibility to make large improvements in the performance of experiments based on this kind of materials. In order to understand the nature of this light emission a measurement at room temperature with TeO{sub 2} crystals was performed. According to these results, the detected light was compatible with the Cherenkov emission, even though the scintillation hypothesis could not be discarded. In this work a Monte Carlo (MC) simulation of the Cherenkov radiation emitted by TeO{sub 2} crystal when crossed by cosmic muons was performed. The data from MC and the room temperature measurement are perfectly compatible and prove that the Cherenkov light is the only component of the light yield of TeO{sub 2} crystals.

  6. Performance of a prototype RICH detector using hybrid photo-diodes

    CERN Document Server

    Albrecht, E; Billy, J H; Brook, N H; Duane, A; French, M; Gibson, V; Giles, R; Halley, A W; Harnew, N; John, M; Miller, D G; O'Shea, V; Teixeira-Dias, P; Smale, N J; Websdale, D M; Wilkinson, G; Wotton, S A

    2001-01-01

    A prototype Ring-Imaging Cherenkov detector has been operated in a charged particle test beam. Cherenkov photons are imaged onto a plane of hybrid photo-diode detectors. The geometrical arrangement of the prototype and data-taking conditions are described. An analysis of the detector performance, using silica aerogel, air and C4F10 gas radiators, is presented. The photon yields and observed angle resolutions are found to be in good agreement with Monte Carlo simulation and satisfy the requirements of the RICH-1 detector in the LHCb experiment.

  7. Tachyonic Cherenkov emission from Jupiter's radio electrons

    Energy Technology Data Exchange (ETDEWEB)

    Tomaschitz, Roman, E-mail: tom@geminga.org

    2013-12-17

    Tachyonic Cherenkov radiation from inertial relativistic electrons in the Jovian radiation belts is studied. The tachyonic modes are coupled to a frequency-dependent permeability tensor and admit a negative mass-square, rendering them superluminal and dispersive. The superluminal radiation field can be cast into Maxwellian form, using 3D field strengths and inductions, and the spectral densities of tachyonic Cherenkov radiation are derived. The negative mass-square gives rise to a longitudinal flux component. A spectral fit to Jupiter's radio spectrum, inferred from ground-based observations and the Cassini 2001 fly-by, is performed with tachyonic Cherenkov flux densities averaged over a thermal electron population.

  8. Cherenkov light-based beam profiling for ultrarelativistic electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Adli, E., E-mail: Erik.Adli@fys.uio.no [Department of Physics, University of Oslo, N-0316 Oslo (Norway); SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Gessner, S.J.; Corde, S.; Hogan, M.J. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Bjerke, H.H. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Department of Physics, Norwegian University of Science and Technology, N-7491 Trondheim (Norway)

    2015-05-21

    We describe a beam profile monitor design based on Cherenkov light emitted from a charged particle beam in an air gap. The main components of the profile monitor are silicon wafers used to reflect Cherenkov light onto a camera lens system. The design allows for measuring large beam sizes, with large photon yield per beam charge and excellent signal linearity with beam charge. The profile monitor signal is independent of the particle energy for ultrarelativistic particles. Different design and parameter considerations are discussed. A Cherenkov light-based profile monitor has been installed at the FACET User Facility at SLAC. We report on the measured performance of this profile monitor.

  9. Search for long-lived heavy charged particles using a ring imaging Cherenkov technique at LHCb

    Energy Technology Data Exchange (ETDEWEB)

    Aaij, R. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Adeva, B. [Universidad de Santiago de Compostela (Spain); Adinolfi, M. [Bristol Univ. (United Kingdom). H.H. Wills Physics Lab.; and others

    2015-12-15

    A search is performed for heavy long-lived charged particles using 3.0 fb{sup -1} of proton-proton collisions collected at √(s) = 7 and 8 TeV with the LHCb detector. The search is mainly based on the response of the ring imaging Cherenkov detectors to distinguish the heavy, slow-moving particles from muons. No evidence is found for the production of such long-lived states. The results are expressed as limits on the Drell-Yan production of pairs of long-lived particles, with both particles in the LHCb pseudorapidity acceptance, 1.8 < η < 4.9. The mass-dependent cross-section upper limits are in the range 2-4 fb (at 95 % CL) for masses between 14 and 309 GeV/c{sup 2}. (orig.)

  10. Search for long-lived heavy charged particles using a ring imaging Cherenkov technique at LHCb

    Energy Technology Data Exchange (ETDEWEB)

    Aaij, R. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Adeva, B. [Universidad de Santiago de Compostela, Santiago de Compostela (Spain); Adinolfi, M. [H.H. Wills Physics Laboratory, University of Bristol, Bristol (United Kingdom); Affolder, A. [Oliver Lodge Laboratory, University of Liverpool, Liverpool (United Kingdom); Ajaltouni, Z. [Clermont Université, Université Blaise Pascal, CNRS/IN2P3, LPC, Clermont-Ferrand (France); and others

    2015-12-15

    A search is performed for heavy long-lived charged particles using 3.0 fb{sup -1} of proton–proton collisions collected at √s= 7 and 8 TeV with the LHCb detector. The search is mainly based on the response of the ring imaging Cherenkov detectors to distinguish the heavy, slow-moving particles from muons. No evidence is found for the production of such long-lived states. The results are expressed as limits on the Drell–Yan production of pairs of long-lived particles, with both particles in the LHCb pseudorapidity acceptance, 1.8<η<4.9. The mass-dependent cross-section upper limits are in the range 2–4 fb (at 95 % CL) for masses between 14 and 309 GeV /c{sup 2}.

  11. The Gamma-ray Cherenkov Telescope for the Cherenkov Telescope Array

    CERN Document Server

    Tibaldo, L; Allan, D; Amans, J -P; Armstrong, T P; Balzer, A; Berge, D; Boisson, C; Bousquet, J -J; Brown, A M; Bryan, M; Buchholtz, G; Chadwick, P M; Costantini, H; Cotter, G; Daniel, M K; De Franco, A; De Frondat, F; Dournaux, J -L; Dumas, D; Ernenwein, J -P; Fasola, G; Funk, S; Gironnet, J; Graham, J A; Greenshaw, T; Hervet, O; Hidaka, N; Hinton, J A; Huet, J -M; Jankowsky, D; Jegouzo, I; Jogler, T; Kraus, M; Lapington, J S; Laporte, P; Lefaucheur, J; Markoff, S; Melse, T; Mohrmann, L; Molyneux, P; Nolan, S J; Okumura, A; Osborne, J P; Parsons, R D; Rosen, S; Ross, D; Rowell, G; Rulten, C B; Sato, Y; Sayede, F; Schmoll, J; Schoorlemmer, H; Servillat, M; Sol, H; Stamatescu, V; Stephan, M; Stuik, R; Sykes, J; Tajima, H; Thornhill, J; Trichard, C; Vink, J; Watson, J J; White, R; Yamane, N; Zech, A; Zink, A; Zorn, J

    2016-01-01

    The Cherenkov Telescope Array (CTA) is a forthcoming ground-based observatory for very-high-energy gamma rays. CTA will consist of two arrays of imaging atmospheric Cherenkov telescopes in the Northern and Southern hemispheres, and will combine telescopes of different types to achieve unprecedented performance and energy coverage. The Gamma-ray Cherenkov Telescope (GCT) is one of the small-sized telescopes proposed for CTA to explore the energy range from a few TeV to hundreds of TeV with a field of view $\\gtrsim 8^\\circ$ and angular resolution of a few arcminutes. The GCT design features dual-mirror Schwarzschild-Couder optics and a compact camera based on densely-pixelated photodetectors as well as custom electronics. In this contribution we provide an overview of the GCT project with focus on prototype development and testing that is currently ongoing. We present results obtained during the first on-telescope campaign in late 2015 at the Observatoire de Paris-Meudon, during which we recorded the first Cher...

  12. Instrumented Water Tanks can Improve Air Shower Detector Sensitivity

    CERN Document Server

    Atkins, R; Berley, D; Chen, M L; Coyne, D G; Delay, R S; Dingus, B L; Dorfan, D E; Ellsworth, R W; Evans, D; Falcone, A D; Fleysher, L; Fleysher, R; Gisler, G; Goodman, J A; Haines, T J; Hoffman, C M; Hugenberger, S; Kelley, L A; Leonor, I; Macri, J R; McConnell, M; McCullough, J F; McEnery, J E; Miller, R S; Mincer, A I; Morales, M F; Némethy, P; Ryan, J M; Schneider, M; Shen, B; Shoup, A L; Sinnis, G; Smith, A J; Sullivan, G W; Thompson, T N; Tümer, T O; Wang, K; Wascko, M O; Westerhoff, S; Williams, D A; Yang, T; Yodh, G B

    1999-01-01

    Previous works have shown that water Cherenkov detectors have superior sensitivity to those of scintillation counters as applied to detecting extensive air showers (EAS). This is in large part due to their much higher sensitivity to EAS photons which are more than five times more numerous than EAS electrons. Large area water Cherenkov detectors can be constructed relatively cheaply and operated reliably. A sparse detector array has been designed which uses these types of detectors to substantially increase the area over which the Milagro Gamma Ray Observatory collects EAS information. Improvements to the Milagro detector's performance characteristics and sensitivity derived from this array and preliminary results from a prototype array currently installed near the Milagro detector will be presented.

  13. A search for the analogue to Cherenkov radiation by high energy neutrinos at superluminal speeds in ICARUS

    CERN Document Server

    Antonello, M.; Baibussinov, B.; Baldo Ceolin, M.; Benetti, P.; Calligarich, E.; Canci, N.; Carbonara, F.; Centro, S.; Cesana, A.; Cieslik, K.; Cline, D.B.; Cocco, A.G.; Dabrowska, A.; Dequal, D.; Dermenev, A.; Dolfini, R.; Farnese, C.; Fava, A.; Ferrari, A.; Fiorillo, G.; Gibin, D.; Gigli Berzolari, A.; Gninenko, S.; Guglielmi, A.; Haranczyk, M.; Holeczek, J.; Ivashkin, A.; Kisiel, J.; Kochanek, I.; Lagoda, J.; Mania, S.; Mannocchi, G.; Menegolli, A.; Meng, G.; Montanari, C.; Otwinowski, S.; Periale, L.; Piazzoli, A.; Picchi, P.; Pietropaolo, F.; Plonski, P.; Rappoldi, A.; Raselli, G.L.; Rossella, M.; Rubbia, C.; Sala, P.R.; Scantamburlo, E.; Scaramelli, A.; Segreto, E.; Sergiampietri, F.; Stefan, D.; Stepaniak, J.; Sulej, R.; Szarska, M.; Terrani, M.; Varanini, F.; Ventura, S.; Vignoli, C.; Wang, H.; Yang, X.; Zalewska, A.; Zaremba, K.; Cohen, A.

    2012-01-01

    The OPERA collaboration [1] has claimed evidence of superluminal propagation between CERN and the LNGS with . We find that the neutrino energy distribution of the ICARUS events in LAr agrees with the expectations from the Monte Carlo predictions from an unaffected energy distribution of beam from CERN. Our results therefore refute a superluminal interpretation of the OPERA result according to the Cohen and Glashow prediction [2] for a weak currents analog to Cherenkov radiation. In particular no events with a superluminal Cherenkov like e+e- pair or gamma emission have been directly observed inside the fiducial volume of the "bubble chamber like" ICARUS TPC-LAr detector, setting much stricter limits to the value of delta comparable with the one due to the observations from the SN1987A.

  14. Simulation studies of an air Cherenkov telescope, IceACT, for future IceCube surface extensions

    Energy Technology Data Exchange (ETDEWEB)

    Hansmann, Bengt; Auffenberg, Jan; Bekman, Ilja; Kemp, Julian; Roegen, Martin; Schaufel, Merlin; Stahlberg, Martin; Wiebusch, Christopher [III. Physikalisches Institut B, RWTH Aachen, Aachen (Germany); Bretz, Thomas; Hebbeker, Thomas; Middendorf, Lukas; Niggemann, Tim; Schumacher, Johannes [III. Physikalisches Institut A, RWTH Aachen, Aachen (Germany); Collaboration: IceCube-Collaboration

    2015-07-01

    IceACT is a compact air Cherenkov telescope using silicon photomultipliers. The Fresnel lens based design has been adopted from the fluorescence telescope FAMOUS. The goal of IceACT is the efficient detection of cosmic ray induced air showers above the IceCube Neutrino Observatory at the geographic South Pole. This allows to distinguish cosmic ray induced muons and neutrinos in the southern sky from astrophysical neutrinos in the deep ice detector. This leads to an increase in low-background astrophysical neutrinos of several dozen events per year for a detection threshold of several 100 TeV cosmic ray primary energy. To determine the actual telescope performance, dedicated CORSIKA air shower simulations incorporating the full Cherenkov light information are performed.

  15. Observations of the Pulsar PSR B1951+32 with the Solar Tower Atmospheric Cherenkov Effect Experiment

    CERN Document Server

    Kildea, J; Ball, J; Carson, J E; Covault, C E; Driscoll, D D; Fortin, P; Gingrich, D M; Hanna, D S; Jarvis, A; Lindner, T; Müller, C; Mukherjee, R; Ong, R A; Ragan, K; Williams, D A

    2007-01-01

    We present the analysis and results of 12.5 hours of high-energy gamma-ray observations of the EGRET-detected pulsar PSR B1951+32 using the Solar Tower Atmospheric Cherenkov Effect Experiment (STACEE). STACEE is an atmospheric Cherenkov detector, in Albuquerque, New Mexico, that detects cosmic gamma rays using the shower-front-sampling technique. STACEE's sensitivity to astrophysical sources at energies around 100 GeV allows it to investigate emission from gamma-ray pulsars with expected pulsed emission cutoffs below 100 GeV. We discuss the observations and analysis of STACEE's PSR 1951+32 data, accumulated during the 2005 and 2006 observing seasons.

  16. A new analysis method for very high definition Imaging Atmospheric Cherenkov Telescopes as applied to the CAT telescope

    CERN Document Server

    Le Bohec, S; Punch, M; Barrau, A; Bazer-Bachi, R; Cabot, H; Chounet, L M; Debiais, G; Dezalay, J P; Djannati-Ataï, A; Dumora, D; Espigat, P; Fabre, B; Fleury, P; Fontaine, G; George, R; Ghesquière, C; Goret, P; Gouiffes, C; Grenier, I A; Iacoucci, L; Malet, I; Meynadier, C; Munz, F; Palfrey, T A; Paré, E; Pons, Y; Québert, J; Ragan, K; Renault, C; Rivoal, M; Rob, L; Schovanek, P; Smith, D; Tavernet, J P; Vrana, J

    1998-01-01

    A new method of shower-image analysis is presented which appears very powerful as applied to those Cherenkov Imaging Telescopes with very high definition imaging capability. It provides hadron rejection on the basis of a single cut on the image shape, and simultaneously determines the energy of the electromagnetic shower and the position of the shower axis with respect to the detector. The source location is also reconstructed for each individual gamma-ray shower, even with one single telescope, so for a point source the hadron rejection can be further improved. As an example, this new method is applied to data from the CAT (Cherenkov Array at Themis) imaging telescope, which has been operational since Autumn, 1996.

  17. Calibration of the Cherenkov Telescope Array

    CERN Document Server

    Gaug, Markus; Berge, David; Reyes, Raquel de los; Doro, Michele; Foerster, Andreas; Maccarone, Maria Concetta; Parsons, Dan; van Eldik, Christopher

    2015-01-01

    The construction of the Cherenkov Telescope Array is expected to start soon. We will present the baseline methods and their extensions currently foreseen to calibrate the observatory. These are bound to achieve the strong requirements on allowed systematic uncertainties for the reconstructed gamma-ray energy and flux scales, as well as on the pointing resolution, and on the overall duty cycle of the observatory. Onsite calibration activities are designed to include a robust and efficient calibration of the telescope cameras, and various methods and instruments to achieve calibration of the overall optical throughput of each telescope, leading to both inter-telescope calibration and an absolute calibration of the entire observatory. One important aspect of the onsite calibration is a correct understanding of the atmosphere above the telescopes, which constitutes the calorimeter of this detection technique. It is planned to be constantly monitored with state-of-the-art instruments to obtain a full molecular and...

  18. Observer Access to the Cherenkov Telescope Array

    CERN Document Server

    Knödlseder, Jürgen; Boisson, Catherine; Brau-Nogué, Sylvie; Deil, Christoph; Khélifi, Bruno; Mayer, Michael; Walter, Roland

    2015-01-01

    The Cherenkov Telescope Array (CTA), a ground-based facility for very-high-energy (VHE) gamma-ray astronomy, will operate as an open observatory, serving a wide scientific community to explore and to study the non-thermal universe. Open community access is a novelty in this domain, putting a challenge on the implementation of services that make VHE gamma-ray astronomy as accessible as any other waveband. We present here the design of the CTA Observer Access system that comprises support of scientific users, dissemination of data and software, tools for scientific analysis, and the system to submit observing proposals. We outline the scientific user workflows and provide the status of the current developments.

  19. Performance of the LHCb RICH Photon Detectors and Tagging Systematics for CP Violation Studies

    CERN Document Server

    Somerville, L P; Harnew, N

    2006-01-01

    The LHCb experiment, currently under construction at CERN, is designed to perform high precision CP violation measurements in the B-meson system. Two Ring Imaging Cherenkov (RICH) detectors provide charged particle identification, and these utilise the novel pixel Hybrid Photon Detectors (HPDs) to detect the Cherenkov photons. A programme was designed and implemented to ensure quality control at each stage of the photon detector production process. A detailed study of the HPD anodes was carried out, including accelerated ageing tests required to demonstrate their robustness over the lifetime of the LHCb experiment. A RICH demonstrator detector with an aerogel radiator was tested in a particle beam and the data were analysed to determine the Cherenkov angle resolution and photon yield. The results were compared with expectations for the detector, taken from a Monte Carlo simulation. The tagging of neutral B mesons, to find their flavour at production, is essential for many CP asymmetry measurements. Biases in ...

  20. X-ray diffraction radiation in conditions of Cherenkov effect

    NARCIS (Netherlands)

    Tishchenko, A. A.; Potylitsyn, A. P.; Strikhanov, M. N.

    2006-01-01

    X-ray diffraction radiation from ultra-relativistic electrons moving near an absorbing target is considered. The emission yield is found to increase significantly in conditions of Cherenkov effect. (c) 2006 Elsevier B.V. All rights reserved.

  1. Extension of Cherenkov Light LDF Approximation for Yakutsk EAS Array

    Directory of Open Access Journals (Sweden)

    A. A. Al-Rubaiee

    2014-01-01

    Full Text Available The simulation of the Cherenkov light lateral distribution function (LDF in extensive air showers (EAS was performed using CORSIKA code for configuration of Yakutsk EAS array at high energy range for different primary particles (p, Fe, and O2 and different zenith angles. Depending on Breit-Wigner function a parameterization of Cherenkov light LDF was reconstructed on the basis of this simulation as a function of primary energy. A comparison of the calculated Cherenkov light LDF with that measured on the Yakutsk EAS array gives the possibility of identification of the particle initiating the shower and determination of its energy in the knee region of the cosmic ray spectrum. The extrapolation of approximated Cherenkov light LDF for high energies was obtained for primary proton and iron nuclei.

  2. Constraint on ghost-free bigravity from gravitational Cherenkov radiation

    Science.gov (United States)

    Kimura, Rampei; Tanaka, Takahiro; Yamamoto, Kazuhiro; Yamashita, Yasuho

    2016-09-01

    We investigate gravitational Cherenkov radiation in a healthy branch of background solutions in the ghost-free bigravity model. In this model, because of the modification of dispersion relations, each polarization mode can possess subluminal phase velocities, and the gravitational Cherenkov radiation could be potentially emitted from a relativistic particle. In the present paper, we derive conditions for the process of the gravitational Cherenkov radiation to occur and estimate the energy emission rate for each polarization mode. We found that the gravitational Cherenkov radiation emitted even from an ultrahigh energy cosmic ray is sufficiently suppressed for the graviton's effective mass less than 100 eV, and the bigravity model with dark matter coupled to the hidden metric is therefore consistent with observations of high energy cosmic rays.

  3. Constraint on ghost-free bigravity from gravitational Cherenkov radiation

    CERN Document Server

    Kimura, Rampei; Yamamoto, Kazuhiro; Yamashita, Yasuho

    2016-01-01

    We investigate gravitational Cherenkov radiation in a healthy branch of background solutions in the ghost-free bigravity model. In this model, because of the modification of dispersion relations, each polarization mode can possess subluminal phase velocities, and the gravitational Cherenkov radiation could be potentially emitted from a relativistic particle. In the present paper, we derive conditions for the process of the gravitational Cherenkov radiation to occur and estimate the energy emission rate for each polarization mode. We found that the gravitational Cherenkov radiation emitted even from an ultrahigh energy cosmic ray is sufficiently suppressed for the graviton's effective mass less than $100\\,{\\rm eV}$, and the bigravity model with dark matter coupled to the hidden metric is therefore consistent with observations of high energy cosmic rays.

  4. Vavilov-Cherenkov and Synchrotron Radiation Foundations and Applications

    CERN Document Server

    Afanasiev, G. N

    2005-01-01

    The theory of the Vavilov-Cherenkov radiation observed by Cherenkov in 1934 was created by Tamm, Frank and Ginsburg who associated the observed blue light with the uniform charge motion of a charge at a velocity greater than the velocity of light in the medium. On the other hand, Vavilov, Cherenkov's teacher, attributed the observed blue light to the deceleration of electrons. This has given rise to the appearance of papers in which the radiation of a charge uniformly moving in a finite space interval was related to the Bremsstrahlung arising at the end points of the motion interval. This monograph is intended for students of the third year and higher, for postgraduates, for professional scientists (both experimentalists and theoreticians) dealing with Vavilov-Cherenkov and synchrotron radiation. An acquaintance with the three volumes of the Landau and Lifshitz course (Quantum Mechanics, Classical Field Theory and Macroscopic Electrodynamics) is sufficient for understanding the text.

  5. Cherenkov light imaging in astro-particle physics

    Science.gov (United States)

    Mirzoyan, Razmik

    2014-12-01

    Cherenkov light emission plays a key role in contemporary science; it is widely used in high energy, nuclear, and numerous astro-particle physics experiments. Most astro-particle physics experiments are based on the detection of light, and a vast majority of them on the measurement of Cherenkov light. Cherenkov light emission is measured in gases (used in air-Cherenkov technique), in water (for example, neutrino experiments BAIKAL, Super-Kamiokande, NESTOR, ANTARES, future KM3NeT; cosmic and γ-ray experiments Milagro, HAWC, AUGER) and in ice (IceCube). In this report our goal is not limited to simply listing the multitude of experiments that are based on using Cherenkov emission, but we will clarify the reasons making this emission so important and so frequently used. For completeness we will first give a short historical overview on the discovery and evolution of Cherenkov emission and then we will dwell on its main features and numerous applications in astro-particle physics experiments.

  6. Aerogel for FARICH detector

    Energy Technology Data Exchange (ETDEWEB)

    Barnyakov, A.Yu. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Barnyakov, M.Yu. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Novosibirsk State Technical University, Karl Marks 20, Novosibirsk 630073 (Russian Federation); Bobrovnikov, V.S.; Buzykaev, A.R.; Gulevich, V.V. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Danilyuk, A.F. [Boreskov Institute of Catalysis, Lavrentieva 5, Novosibirsk 630090 (Russian Federation); Kononov, S.A.; Kravchenko, E.A. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Novosibirsk State University, Pirogova 2, Novosibirsk 630090 (Russian Federation); Kuyanov, I.A. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Lopatin, S.A. [Boreskov Institute of Catalysis, Lavrentieva 5, Novosibirsk 630090 (Russian Federation); Onuchin, A.P.; Ovtin, I.V.; Podgornov, N.A. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Novosibirsk State Technical University, Karl Marks 20, Novosibirsk 630073 (Russian Federation); Porosev, V.V. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Predein, A.Yu.; Protsenko, R.S. [Boreskov Institute of Catalysis, Lavrentieva 5, Novosibirsk 630090 (Russian Federation)

    2014-12-01

    We present our current experience in preparation of focusing aerogels for the Focusing Aerogel RICH detector. Multilayer focusing aerogel tiles have been produced in Novosibirsk by a collaboration of the Budker Institute of Nuclear Physics and Boreskov Institute of Catalysis since 2004. We have obtained 2–3–4-layer blocks with the thickness of 30–45 mm. In 2012, the first samples of focusing blocks with continuous density (refractive index) gradient along thickness were produced. This technology can significantly reduce the contribution from the geometric factor of the radiator thickness to the resolution of the measured Cherenkov angle in the FARICH detector. The special installation was used for automatic control of reagents ratio during the synthesis process. The first samples were tested using the digital radiography method and on the electron beam with the FARICH prototype.

  7. Silicon Photomultipliers and front-end electronics performance for Cherenkov Telescope Array camera development

    Science.gov (United States)

    Ambrosi, G.; Bissaldi, E.; Giglietto, N.; Giordano, F.; Ionica, M.; Paoletti, R.; Rando, R.; Simone, D.; Vagelli, V.

    2017-02-01

    In the last few years a number of efforts have been undertaken to develop new technology related to Silicon Photomultipliers (SiPMs). These photosensors consist of an array of identical Avalanche Photodiodes operating in Geiger mode and connected in parallel to a single output. The Italian Institute of Nuclear Physics (INFN) is involved in the R&D program Progetto Premiale Telescopi CHErenkov made in Italy (TECHE.it) to develop photosensors for a SiPM based camera that will be part of the Cherenkov Telescope Array (CTA) observatory. In this framework tests are ongoing on innovative devices suitable to detect Cherenkov light in the blue and near-UV wavelength region, the so-called Near Ultra-Violet Silicon Photomultipliers (NUV SiPMs). The tests on photosensors produced by Fondazione Bruno Kessler (FBK) are revealing promising performance: low operating voltage, capability to detect very low intensity light down to a single photon and high Photo Detection Efficiency (PDE) in the range 390-410 nm. In particular the developed device is a High Density NUV-SiPM (NUV-HD SiPM) based on a micro-cell of 30 μm×30 μm and 6 mm×6 mm area. Tests on this detector in single-cell configuration and in a matrix arrangement have been done. At the same time front-end electronics based on the waveform sampling technique optimized for the new NUV-HD SIPMs is under study and development.

  8. Status of the photomultiplier-based FlashCam camera for the Cherenkov Telescope Array

    Science.gov (United States)

    Pühlhofer, G.; Bauer, C.; Eisenkolb, F.; Florin, D.; Föhr, C.; Gadola, A.; Garrecht, F.; Hermann, G.; Jung, I.; Kalekin, O.; Kalkuhl, C.; Kasperek, J.; Kihm, T.; Koziol, J.; Lahmann, R.; Manalaysay, A.; Marszalek, A.; Rajda, P. J.; Reimer, O.; Romaszkan, W.; Rupinski, M.; Schanz, T.; Schwab, T.; Steiner, S.; Straumann, U.; Tenzer, C.; Vollhardt, A.; Weitzel, Q.; Winiarski, K.; Zietara, K.

    2014-07-01

    The FlashCam project is preparing a camera prototype around a fully digital FADC-based readout system, for the medium sized telescopes (MST) of the Cherenkov Telescope Array (CTA). The FlashCam design is the first fully digital readout system for Cherenkov cameras, based on commercial FADCs and FPGAs as key components for digitization and triggering, and a high performance camera server as back end. It provides the option to easily implement different types of trigger algorithms as well as digitization and readout scenarios using identical hardware, by simply changing the firmware on the FPGAs. The readout of the front end modules into the camera server is Ethernet-based using standard Ethernet switches and a custom, raw Ethernet protocol. In the current implementation of the system, data transfer and back end processing rates of 3.8 GB/s and 2.4 GB/s have been achieved, respectively. Together with the dead-time-free front end event buffering on the FPGAs, this permits the cameras to operate at trigger rates of up to several ten kHz. In the horizontal architecture of FlashCam, the photon detector plane (PDP), consisting of photon detectors, preamplifiers, high voltage-, control-, and monitoring systems, is a self-contained unit, mechanically detached from the front end modules. It interfaces to the digital readout system via analogue signal transmission. The horizontal integration of FlashCam is expected not only to be more cost efficient, it also allows PDPs with different types of photon detectors to be adapted to the FlashCam readout system. By now, a 144-pixel mini-camera" setup, fully equipped with photomultipliers, PDP electronics, and digitization/ trigger electronics, has been realized and extensively tested. Preparations for a full-scale, 1764 pixel camera mechanics and a cooling system are ongoing. The paper describes the status of the project.

  9. Detectors - Electronics; Detecteurs - Electronique

    Energy Technology Data Exchange (ETDEWEB)

    Bregeault, J.; Gabriel, J.L.; Hierle, G.; Lebotlan, P.; Leconte, A.; Lelandais, J.; Mosrin, P.; Munsch, P.; Saur, H.; Tillier, J. [Lab. de Physique Corpusculaire, Caen Univ., 14 (France)

    1998-04-01

    The reports presents the main results obtained in the fields of radiation detectors and associated electronics. In the domain of X-ray gas detectors for the keV range efforts were undertaken to rise the detector efficiency. Multiple gap parallel plate chambers of different types as well as different types of X {yields} e{sup -} converters were tested to improve the efficiency (values of 2.4% at 60 KeV were reached). In the field of scintillators a study of new crystals has been carried out (among which Lutetium orthosilicate). CdTe diode strips for obtaining X-ray imaging were studied. The complete study of a linear array of 8 CdTe pixels has been performed and certified. The results are encouraging and point to this method as a satisfying solution. Also, a large dimension programmable chamber was used to study the influence of temperature on the inorganic scintillators in an interval from -40 deg. C to +150 deg. C. Temperature effects on other detectors and electronic circuits were also investigated. In the report mentioned is also the work carried out for the realization of the DEMON neutron multidetector. For neutron halo experiments different large area Si detectors associated with solid and gas position detectors were realized. In the frame of a contract with COGEMA a systematic study of Li doped glasses was undertaken aiming at replacing with a neutron probe the {sup 3}He counters presently utilized in pollution monitoring. An industrial prototype has been realised. Other studies were related to integrated analog chains, materials for Cherenkov detectors, scintillation probes for experiments on fundamental processes, gas position sensitive detectors, etc. In the field of associated electronics there are mentioned the works related to the multidetector INDRA, data acquisition, software gamma spectrometry, automatic gas pressure regulation in detectors, etc

  10. Kilometer-Scale Neutrino Detectors: First Light

    CERN Document Server

    Halzen, Francis

    2009-01-01

    This is a brief report on the status of neutrino "astronomy" at a time when the kilometer-scale neutrino detector IceCube is approaching completion. We revisit the rationale for constructing gigantic neutrino detectors by transforming large volumes of natural ice and water into Cherenkov detectors. With time, the motivation for building such instruments has come into clear focus, and the requirement for their kilometer scale has been rationalized with improved accuracy. We will discuss the performance and some selected results of IceCube based on data taken during construction.

  11. A method of observing cherenkov light from extensive air shower at Yakutsk EAS array

    Science.gov (United States)

    Timofeev, Lev; Anatoly, Ivanov

    2016-07-01

    Proposed a new method for measuring the cherenkov light from the extensive air shower (EAS) of cosmic rays (CR), which allows to determine not only the primary particle energy and angle of arrival, but also the parameters of the shower in the atmosphere - the maximum depth and "age". For measurements Cherenkov light produced by EAS is proposed to use a ground network of wide-angle telescopes which are separated from each other by a distance 100-300 m depending on the total number of telescopes operating in the coincidence signals, acting autonomously, or includes a detector of the charged components, radio waves, etc. as part of EAS. In a results such array could developed, energy measurement and CR angle of arrival data on the depth of the maximum and the associated mass of the primary particle generating by EAS. This is particularly important in the study of galactic cosmic ray in E> 10^14 eV, where currently there are no direct measurements of the maximum depth of the EAS.

  12. Design and Experimental Demonstration of Cherenkov Radiation Source Based on Metallic Photonic Crystal Slow Wave Structure

    Science.gov (United States)

    Fu, Tao; Yang, Zi-Qiang; Ouyang, Zheng-Biao

    2016-11-01

    This paper presents a kind of Cherenkov radiation source based on metallic photonic crystal (MPC) slow-wave structure (SWS) cavity. The Cherenkov source designed by linear theory works at 34.7 GHz when the cathode voltage is 550 kV. The three-dimensional particle-in-cell (PIC) simulation of the SWS shows the operating frequency of 35.56 GHz with a single TM01 mode is basically consistent with the theoretically one under the same parameters. An experiment was implemented to testify the results of theory and PIC simulation. The experimental system includes a cathode emitting unit, the SWS, a magnetic system, an output antenna, and detectors. Experimental results show that the operating frequency through detecting the retarded time of wave propagation in waveguides is around 35.5 GHz with a single TM01 mode and an output power reaching 54 MW. It indicates that the MPC structure can reduce mode competition. The purpose of the paper is to show in theory and in preliminary experiment that a SWS with PBG can produce microwaves in TM01 mode. But it still provides a good experimental and theoretical foundation for designing high-power microwave devices.

  13. GAW - An Imaging Atmospheric Cherenkov Telescope with Large Field of View

    CERN Document Server

    Cusumano, G; Alberdi, A; Alvarez, M; Assis, P; Biondo, B; Bocchino, F; Brogueira, P; Caballero, J A; Carvajal, M; Castro-Tirado, A J; Catalano, O; Celi, F; Delgado, C; Di Cocco, G; Dominguez, A; Navas, J M Espino; Santo, M C Espirito; Gallardo, M I; García, J E; Giarrusso, S; Gómez, M; Gómez, J L; Gonçalves, P; Guerriero, M; La Barbera, A; La Rosa, G; Lozano, M; Maccarone, M C; Mangano, A; Martel, I; Massaro, E; Mineo, T; Moles, M; Pérez-Bernal, F; Peres-Torres, M A; Pimenta, M; Pina, A; Prada, F; Quesada, J M; Quintana, J M; Quintero, J R; Rodríguez, J; Russo, F; Sacco, B; Sanchez-Conde, M A; Segreto, A; Tome', B; Postigo, A de Ugarte; Vallania, P

    2007-01-01

    GAW, acronym for Gamma Air Watch, is a Research and Development experiment in the TeV range, whose main goal is to explore the feasibility of large field of view Imaging Atmospheric Cherenkov Telescopes. GAW is an array of three relatively small telescopes (2.13 m diameter) which differs from the existing and presently planned projects in two main features: the adoption of a refractive optics system as light collector and the use of single photoelectron counting as detector working mode. The optics system allows to achieve a large field of view (24x24 squared degrees) suitable for surveys of large sky regions. The single photoelectron counting mode in comparison with the charge integration mode improves the sensitivity by permitting also the reconstruction of events with a small number of collected Cherenkov photons. GAW, which is a collaboration effort of Research Institutes in Italy, Portugal and Spain, will be erected in the Calar Alto Observatory (Sierra de Los Filabres - Andalucia, Spain), at 2150 m a.s....

  14. Approximation of lateral distribution of atmospheric Cherenkov light at different observation levels. Comparison with previous results

    CERN Document Server

    Mishev, A; Stamenov, J

    2005-01-01

    This work summarizes the results presented at 29th International Cosmic Ray Conference in Pune India. Generally the aim of this work is to obtain the lateral distribution of the atmospheric Cherenkov light in extensive air showers produced by different primary particles in wide energy range and at several observation levels and to fit the obtained lateral distributions. Using one large detector and partially modified CORSIKA code version are obtained the lateral distributions of Cherenkov light flux densities at several observation levels for different particle primaries precisely at 536 g/cm2 Chacaltaya, 700 g/cm2 Moussala and 875 g/cm2 Kartalska field observation levels for hadronic primaries and gamma quanta in the energy range 1011 eV-1016 eV. On the basis of the solution of over-determined inverse problem the approximation of these distributions is obtained. The same model function for all the primaries is used and for the different observation levels. The different model parameters for the different pri...

  15. Prototype of a production system for Cherenkov Telescope Array with DIRAC

    CERN Document Server

    Arrabito, L; Haupt, A; Graciani Diaz, R; Stagni, F; Tsaregorodtsev, A

    2015-01-01

    The Cherenkov Telescope Array (CTA) — an array of many tens of Imaging Atmospheric Cherenkov Telescopes deployed on an unprecedented scale — is the next generation instrument in the field of very high energy gamma-ray astronomy. CTA will operate as an open observatory providing data products to the scientific community. An average data stream of about 10 GB/s for about 1000 hours of observation per year, thus producing several PB/year, is expected. Large CPU time is required for data-processing as well for massive Monte Carlo simulations needed for detector calibration purposes. The current CTA computing model is based on a distributed infrastructure for the archive and the data off-line processing. In order to manage the off-line data-processing in a distributed environment, CTA has evaluated the DIRAC (Distributed Infrastructure with Remote Agent Control) system, which is a general framework for the management of tasks over distributed heterogeneous computing environments. In particular, a production sy...

  16. Observations of Active Galactic Nuclei by the Solar Tower Atmospheric Cherenkov Effect Experiment (STACEE)

    Science.gov (United States)

    Covault, C. E.; Boone, L.M.; Bramel, D.; Carson, J.; Fortin, P.; Gauthier, G.; Gingrich, D.; Hanna, D.; Jarvis, A.; Kildea, J.; Mueller, C.; Mukherjee, R.; Ong, R.A.; Ragan, K.; Scalzo, R.A.; Williams, D.A.; Zweerink, J.

    2003-07-01

    We present new results from observations of Active Galactic Nuclei (AGN) by the STACEE experiment. STACEE is a detector for 50-500 GeV gamma rays which uses the array of heliostat mirrors at the National Solar Thermal Test Facility (NSTTF) located at Sandia Lab oratories, Albuquerque, New Mexico, USA. STACEE uses 64 of these heliostats at night to collect Cherenkov light from air showers due to high energy gamma rays. With a large collecting area, STACEE has good sensitivity below 100 GeV. This allow us to search for gamma rays from extragalactic sources at larger redshift distances (to z of 0.2 or more) than can be studied by more conventional imaging Cherenkov telescopes operating at higher energy thresholds. We summarize recent STACEE observations of W Comae (also known as ON+231), Markarian 421, and H 1426+428. Analysis of observations on these sources in ongoing, and new results will be presented at the conference. We also briefly describe plans for future STACEE observations of AGN in the context of multiwavelength campaigns.

  17. FastDIRC: a fast Monte Carlo and reconstruction algorithm for DIRC detectors

    CERN Document Server

    Hardin, John

    2016-01-01

    FastDIRC is a novel fast Monte Carlo and reconstruction algorithm for DIRC detectors. A DIRC employs rectangular fused-silica bars both as Cherenkov radiators and as light guides. Cherenkov-photon imaging and time-of-propagation information are utilized by a DIRC to identify charged particles. GEANT-based DIRC Monte Carlo simulations are extremely CPU intensive. The FastDIRC algorithm permits fully simulating a DIRC detector more than 10000 times faster than using GEANT. This facilitates designing a DIRC-reconstruction algorithm that improves the Cherenkov-angle resolution of a DIRC detector by about 30% compared to existing algorithms. FastDIRC also greatly reduces the time required to study competing DIRC-detector designs.

  18. Discovery potential for supernova relic neutrinos with slow liquid scintillator detectors

    CERN Document Server

    Wei, Hanyu; Chen, Shaomin

    2016-01-01

    The detection of supernova relic neutrinos would provide a key support for our current understanding of stellar and cosmological evolution, and precise measurements of them would further give us an insight of the profound universe. In this paper we study the potential to detect supernova relic neutrinos using linear alkyl benzene, LAB, as a slow liquid scintillator, which features a good separation of Cherenkov and scintillation lights, thus providing a new ability in particle identification. We also address key issues of current experiments, including 1) the charged current background of atmospheric neutrinos in water Cherenkov detectors, and 2) the neutral current background of atmospheric neutrinos in typical liquid scintillator detectors. With LAB, a kiloton-scale detector, like the SNO, KamLAND, and the future Jinping neutrino detectors, with $\\mathcal{O}$(10) years of data, would have the sensitivity to discover supernova relic neutrinos, which is comparable to large-volume water Cherenkov, typical liqu...

  19. Cherenkov radiation conversion and collection considerations for a gamma bang time/reaction history diagnostic for the NIF.

    Science.gov (United States)

    Herrmann, Hans W; Mack, Joseph M; Young, Carlton S; Malone, Robert M; Stoeffl, Wolfgang; Horsfield, Colin J

    2008-10-01

    Bang time and reaction history measurements are fundamental components of diagnosing inertial confinement fusion (ICF) implosions and will be essential contributors to diagnosing attempts at ignition on the National Ignition Facility (NIF). Fusion gammas provide a direct measure of fusion interaction rate without being compromised by Doppler spreading. Gamma-based gas Cherenkov detectors that convert fusion gamma rays to optical Cherenkov photons for collection by fast recording systems have been developed and fielded at Omega. These systems have established their usefulness in illuminating ICF physics in several experimental campaigns. Bang time precision better than 25 ps has been demonstrated, well below the 50 ps accuracy requirement defined by the NIF system design requirements. A comprehensive, validated numerical study of candidate systems is providing essential information needed to make a down selection based on optimization of sensitivity, bandwidth, dynamic range, cost, and NIF logistics. This paper presents basic design considerations arising from the two-step conversion process from gamma rays to relativistic electrons to UV/visible Cherenkov radiation.

  20. Comparison of Cherenkov excited fluorescence and phosphorescence molecular sensing from tissue with external beam irradiation.

    Science.gov (United States)

    Lin, Huiyun; Zhang, Rongxiao; Gunn, Jason R; Esipova, Tatiana V; Vinogradov, Sergei; Gladstone, David J; Jarvis, Lesley A; Pogue, Brian W

    2016-05-21

    Ionizing radiation delivered by a medical linear accelerator (LINAC) generates Cherenkov emission within the treated tissue. A fraction of this light, in the 600-900 nm wavelength region, propagates through centimeters of tissue and can be used to excite optical probes in vivo, enabling molecular sensing of tissue analytes. The success of isolating the emission signal from this Cherenkov excitation background is dependent on key factors such as: (i) the Stokes shift of the probe spectra; (ii) the excited state lifetime; (iii) the probe concentration; (iv) the depth below the tissue surface; and (v) the radiation dose used. Previous studies have exclusively focused on imaging phosphorescent dyes, rather than fluorescent dyes. However there are only a few biologically important phosphorescent dyes and yet in comparison there are thousands of biologically relevant fluorescent dyes. So in this study the focus was a study of efficacy of Cherenkov-excited luminescence using fluorescent commercial near-infrared probes, IRDye 680RD, IRDye 700DX, and IRDye 800CW, and comparing them to the well characterized phosphorescent probe Oxyphor PtG4, an oxygen sensitive dye. Each probe was excited by Cherenkov light from a 6 MV external radiation beam, and measured in continuous wave or time-gated modes. The detection was performed by spectrally resolving the luminescence signals, and measuring them with spectrometer-based separation on an ICCD detector. The results demonstrate that IRDye 700DX and PtG4 allowed for the maximal signal to noise ratio. In the case of the phosphorescent probe, PtG4, with emission decays on the microsecond (μs) time scale, time-gated acquisition was possible, and it allowed for higher efficacy in terms of the probe concentration and detection depth. Phantoms containing the probe at 5 mm depth could be detected at concentrations down to the nanoMolar range, and at depths into the tissue simulating phantom near 3 cm. In vivo studies showed that 5

  1. Trigger and aperture of the surface detector array of the Pierre Auger Observatory

    NARCIS (Netherlands)

    Abraham, J.; Abreu, P.; Aglietta, M.; Ahn, E. J.; Allard, D.; Allekotte, I.; Allen, J.; Alvarez-Muniz, J.; Ambrosio, M.; Anchordoqui, L.; Andringa, S.; Anticic, T.; Anzalone, A.; Aramo, C.; Arganda, E.; Arisaka, K.; Arqueros, F.; Asorey, H.; Assis, P.; Aublin, J.; Ave, M.; Avila, G.; Baecker, T.; Badagnani, D.; Balzer, M.; Barber, K. B.; Barbosa, A. F.; Barroso, S. L. C.; Baughman, B.; Bauleo, P.; Beatty, J. J.; Becker, B. R.; Becker, K. H.; Belletoile, A.; Bellido, J. A.; BenZvi, S.; Berat, C.; Bergmann, T.; Bertou, X.; Biermann, P. L.; Billoir, P.; Blanch-Bigas, O.; Blanco, F.; Blanco, M.; Bleve, C.; Bluemer, H.; Bohacova, M.; Boncioli, D.; Bonifazi, C.; Bonino, R.; Borodai, N.; Brack, J.; Brogueira, P.; Brown, W. C.; Bruijn, R.; Buchholz, P.; Bueno, A.; Burton, R. E.; Busca, N. G.; Caballero-Mora, K. S.; Caramete, L.; Caruso, R.; Castellina, A.; Catalano, O.; Cataldi, G.; Cazon, L.; Cester, R.; Chauvin, J.; Chiavassa, A.; Chinellato, J. A.; Chou, A.; Chudoba, J.; Clay, R. W.; Colombo, E.; Coluccia, M. R.; Conceicao, R.; Contreras, F.; Cook, H.; Cooper, M. J.; Coppens, J.; Cordier, A.; Cotti, U.; Coutu, S.; Covault, C. E.; Creusot, A.; Criss, A.; Cronin, J.; Curutiu, A.; Dagoret-Campagne, S.; Dallier, R.; Daumiller, K.; Dawson, B. R.; de Almeida, R. M.; De Domenico, M.; De Donato, C.; de Jong, S. J.; De La Vega, G.; de Mello Junior, W. J. M.; de Mello Neto, J. R. T.; De Mitri, I.; de Souza, V.; de Vries, K. D.; Decerprit, G.; del Peral, L.; Deligny, O.; Della Selva, A.; Delle Fratte, C.; Dembinski, H.; Di Giulio, C.; Diaz, J. C.; Castro, M. L. Diaz; Diep, P. N.; Dobrigkeit, C.; D'Olivo, J. C.; Dong, P. N.; Dorofeev, A.; dos Anjos, J. C.; Dova, M. T.; D'Urso, D.; Dutan, I.; DuVernois, M. A.; Ebr, J.; Engel, R.; Erdmann, M.; Escobar, C. O.; Etchegoyen, A.; Facal San Luis, P.; Falcke, H.; Farrar, G.; Fauth, A. C.; Fazzini, N.; Ferrero, A.; Fick, B.; Filevich, A.; Filipcic, A.; Fleck, I.; Fliescher, S.; Fracchiolla, C. E.; Fraenkel, E. D.; Froehlich, U.; Fulgione, W.; Gamarra, R. F.; Gambetta, S.; Garcia, B.; Garcia Gamez, D.; Garcia-Pinto, D.; Garrido, X.; Gelmini, G.; Gemmeke, H.; Ghia, P. L.; Giaccari, U.; Giller, M.; Glass, H.; Goggin, L. M.; Gold, M. S.; Golup, G.; Gomez Albarracin, F.; Gomez Berisso, M.; Goncalves, P.; Gonzalez, D.; Gonzalez, J. G.; Gora, D.; Gorgi, A.; Gouffon, P.; Gozzini, S. R.; Grashorn, E.; Grebe, S.; Grigat, M.; Grillo, A. F.; Guardincerri, Y.; Guarino, F.; Guedes, G. P.; Hague, J. D.; Halenka, V.; Hansen, P.; Harari, D.; Harmsma, S.; Harton, J. L.; Haungs, A.; Hebbeker, T.; Heck, D.; Herve, A. E.; Hojvat, C.; Holmes, V. C.; Homola, P.; Hoerandel, J. R.; Horneffer, A.; Hrabovsky, M.; Huege, T.; Hussain, M.; Iarlori, M.; Insolia, A.; Ionita, F.; Italiano, A.; Jiraskova, S.; Kadija, K.; Kaducak, M.; Kampert, K. H.; Karova, T.; Kasper, P.; Kegl, B.; Keilhauer, B.; Keivani, A.; Kelley, J.; Kemp, E.; Kieckhafer, R. M.; Klages, H. O.; Kleifges, M.; Kleinfeller, J.; Knapik, R.; Knapp, J.; Koang, D. -H.; Krieger, A.; Kroemer, O.; Kruppke-Hansen, D.; Kuehn, F.; Kuempel, D.; Kulbartz, K.; Kunka, N.; Kusenko, A.; La Rosa, G.; Lachaud, C.; Lago, B. L.; Lautridou, P.; Leao, M. S. A. B.; Lebrun, D.; Lebrun, P.; Lee, J.; Leigui de Oliveira, M. A.; Lemiere, A.; Letessier-Selvon, A.; Lhenry-Yvon, I.; Lopez, R.; Lopez Aguera, A.; Louedec, K.; Lozano Bahilo, J.; Lucero, A.; Ludwig, M.; Lyberis, H.; Maccarone, M. C.; Macolino, C.; Maldera, S.; Mandat, D.; Mantsch, P.; Mariazzi, A. G.; Marin, V.; Maris, I. C.; Marquez Falcon, H. R.; Marsella, G.; Martello, D.; Martinez Bravo, O.; Mathes, H. J.; Matthews, J.; Matthews, J. A. J.; Matthiae, G.; Maurizio, D.; Mazur, P. O.; McEwen, M.; Medina-Tanco, G.; Melissas, M.; Melo, D.; Menichetti, E.; Menshikov, A.; Meurer, C.; Micanovic, S.; Micheletti, M. I.; Miller, W.; Miramonti, L.; Mollerach, S.; Monasor, M.; Ragaigne, D. Monnier; Montanet, F.; Morales, B.; Morello, C.; Moreno, E.; Moreno, J. C.; Morris, C.; Mostafa, M.; Mueller, S.; Muller, M. A.; Mussa, R.; Navarra, G.; Navarro, J. L.; Navas, S.; Necesal, P.; Nellen, L.; Nhung, P. T.; Nierstenhoefer, N.; Nitz, D.; Nosek, D.; Nozka, L.; Nyklicek, M.; Oehlschlaeger, J.; Olinto, A.; Oliva, P.; Olmos-Gilbaja, V. M.; Ortiz, M.; Pacheco, N.; Selmi-Dei, D. Pakk; Palatka, M.; Pallotta, J.; Palmieri, N.; Parente, G.; Parizot, E.; Parlati, S.; Parra, A.; Parrisius, J.; Parsons, R. D.; Pastor, S.; Paul, T.; Pavlidou, V.; Payet, K.; Pech, M.; Pekala, J.; Pelayo, R.; Pepe, I. M.; Perrone, L.; Pesce, R.; Petermann, E.; Petrera, S.; Petrinca, P.; Petrolini, A.; Petrov, Y.; Petrovic, J.; Pfendner, C.; Piegaia, R.; Pierog, T.; Pimenta, M.; Pirronello, V.; Platino, M.; Ponce, V. H.; Pontz, M.; Privitera, P.; Prouza, M.; Quel, E. J.; Rautenberg, J.; Ravel, O.; Ravignani, D.; Redondo, A.; Revenu, B.; Rezende, F. A. S.; Ridky, J.; Riggi, S.; Risse, M.; Ristori, P.; Riviere, C.; Rizi, V.; Robledo, C.; Rodriguez, G.; Rodriguez Martino, J.; Rodriguez Rojo, J.; Rodriguez-Cabo, I.; Rodriguez-Frias, M. D.; Ros, G.; Rosado, J.; Rossler, T.; Roth, M.; Rouille-d'Orfeuil, B.; Roulet, E.; Rovero, A. C.; Salamida, F.; Salazar, H.; Salina, G.; Sanchez, F.; Santander, M.; Santo, C. E.; Santo, E.; Santos, E. M.; Sarazin, F.; Sarkar, S.; Sato, R.; Scharf, N.; Scherini, V.; Schieler, H.; Schiffer, P.; Schmidt, A.; Schmidt, F.; Schmidt, T.; Scholten, O.; Schoorlemmer, H.; Schovancova, J.; Schovanek, P.; Schroeder, F.; Schulte, S.; Schuessler, F.; Schuster, D.; Sciutto, S. J.; Scuderi, M.; Segreto, A.; Semikoz, D.; Settimo, M.; Shellard, R. C.; Sidelnik, I.; Siffert, B. B.; Sigl, G.; Smialkowski, A.; Smida, R.; Snow, G. R.; Sommers, P.; Sorokin, J.; Spinka, H.; Squartini, R.; Stasielak, J.; Stephan, M.; Strazzeri, E.; Stutz, A.; Suarez, F.; Suomijarvi, T.; Supanitsky, A. D.; Susa, T.; Sutherland, M. S.; Swain, J.; Szadkowski, Z.; Tamashiro, A.; Tamburro, A.; Tapia, A.; Tarutina, T.; Tascau, O.; Tcaciuc, R.; Tcherniakhovski, D.; Tegolo, D.; Thao, N. T.; Thomas, D.; Tiffenberg, J.; Timmermans, C.; Tkaczyk, W.; Peixoto, C. J. Todero; Tome, B.; Tonachini, A.; Travnicek, P.; Tridapalli, D. B.; Tristram, G.; Trovato, E.; Tueros, M.; Ulrich, R.; Unger, M.; Urban, M.; Valdes Galicia, J. F.; Valino, I.; Valore, L.; van den Berg, A. M.; Vazquez, J. R.; Vazquez, R. A.; Veberic, D.; Venters, T.; Verzi, V.; Videla, M.; Villasenor, L.; Vorobiov, S.; Voyvodic, L.; Wahlberg, H.; Wahrlich, P.; Wainberg, O.; Warner, D.; Watson, A. A.; Westerhoff, S.; Whelan, B. J.; Wieczorek, G.; Wiencke, L.; Wilczynska, B.; Wilczynski, H.; Williams, C.; Winchen, T.; Winnick, M. G.; Wundheiler, B.; Yamamoto, T.; Younk, P.; Yuan, G.; Yushkov, A.; Zas, E.; Zavrtanik, D.; Zavrtanik, M.; Zaw, I.; Zepeda, A.; Ziolkowski, M.

    2010-01-01

    The surface detector array of the Pierre Auger Observatory consists of 1600 water-Cherenkov detectors, for the study of extensive air showers (EAS) generated by ultra-high-energy cosmic rays. We describe the trigger hierarchy, from the identification of candidate showers at the level of a single det

  2. IceCube: A Cubic Kilometer Radiation Detector

    OpenAIRE

    Klein, S.; IceCube Collaboration

    2008-01-01

    IceCube is a 1 km^3 neutrino detector now being built at the Amundsen-Scott South Pole Station. It consists of 4800 Digital Optical Modules (DOMs) which detect Cherenkov radiation from the charged particles produced in neutrino interactions. IceCube will observe astrophysical neutrinos with energies above about 100 GeV. IceCube will be able to separate \

  3. Strangeonium spectroscopy at 11 GeV/c and Cherenkov Ring Imaging at the SLD

    Energy Technology Data Exchange (ETDEWEB)

    Bienz, T.L.

    1990-07-01

    This thesis is divided into two sections, which describe portions of the data acquisition system and online software for the Cherenkov Ring Imaging Detector (CRID) for the SLD, and analyses of several low cross section strangeonium channels in data from the LASS spectrometer. The CRID section includes a description of the data acquisition system, determination of the preamplifier gain, and development of an online pulse finding algorithm based on deconvolution. Deconvolution uses knowledge of the preamplifier impulse response to aid in pulse finding. The algorithm is fast and shows good single pulse resolution and excellent double pulse resolution in preliminary tests. The strangeonium analyses are based on data from a 4.1 event/nanobarn exposure of the LASS spectrometer in K{sup {minus}}p interactions at 11 GeV/c, and include studies of {Lambda}{eta}{pi}{sup {plus}}{pi}{sup {minus}}, {Lambda}{Kappa}*{Kappa}*, and {Lambda}{phi}{phi}.

  4. Evaluation of Photo Multiplier Tube candidates for the Cherenkov Telescope Array

    Energy Technology Data Exchange (ETDEWEB)

    Mirzoyan, R. [Max-Planck-Institute for Physics, Föhringer Ring 6, 80805 Munich (Germany); Müller, D., E-mail: dmueller@mpp.mpg.de [Max-Planck-Institute for Physics, Föhringer Ring 6, 80805 Munich (Germany); Hanabata, Y. [Institute for Cosmic Ray Research, The University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Hose, J.; Menzel, U. [Max-Planck-Institute for Physics, Föhringer Ring 6, 80805 Munich (Germany); Nakajima, D.; Takahashi, M. [Institute for Cosmic Ray Research, The University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Teshima, M. [Max-Planck-Institute for Physics, Föhringer Ring 6, 80805 Munich (Germany); Institute for Cosmic Ray Research, The University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Toyama, T. [Max-Planck-Institute for Physics, Föhringer Ring 6, 80805 Munich (Germany); Yamamoto, T. [Department of Physics, Konan University, Okamoto 8-9-1, Higashinada-ku, Kobe, Hyogo 658-0072 (Japan)

    2016-07-11

    Photo Multiplier Tubes (PMTs) are the most wide spread detectors for fast, faint light signals. Six years ago, an improvement program for the PMT candidates for the Cherenkov Telescope Array (CTA) project was started with the companies Hamamatsu Photonics K.K. and Electron Tubes Enterprises Ltd. (ETE). For maximizing the performance of the CTA imaging cameras we need PMTs with outstanding good quantum efficiency, high photoelectron collection efficiency, short pulse width, very low afterpulse probability and transit time spread. We will report on the measurements of PMT R-12992-100 from Hamamatsu as their final product and the PMT D573KFLSA as one of the latest test versions from ETE as candidate PMTs for the CTA project.

  5. CHIPS Neutrino Detector Research and Development

    Science.gov (United States)

    Salazar, Ramon; Vahle, Patricia; Chips Collaboration

    2015-04-01

    The CHIPS R&D project is an effort to develop affordable megaton-scale neutrino detectors. The CHIPS strategy calls for submerging water Cherenkov detectors deep under water. The surrounding water acts as structural support, minimizing large initial investments in costly infrastructure, and serves as an overburden, shielding the detector from cosmic rays and eliminating the need for expensive underground construction. Additional cost savings will be achieved through photodetector development and optimization of readout geometry. In summer 2014 a small prototype of the CHIPS detector was deployed in the flooded Wentworth Mine Pit in Northern Minnesota. The detector has been recording data underwater throughout the fall and winter. In this talk, we will discuss lessons learned from the prototyping experience and the plans for submerging much larger detectors in future years.

  6. The first GCT camera for the Cherenkov Telescope Array

    CERN Document Server

    De Franco, A.; Allan, D.; Armstrong, T.; Ashton, T.; Balzer, A.; Berge, D.; Bose, R.; Brown, A.M.; Buckley, J.; Chadwick, P.M.; Cooke, P.; Cotter, G.; Daniel, M.K.; Funk, S.; Greenshaw, T.; Hinton, J.; Kraus, M.; Lapington, J.; Molyneux, P.; Moore, P.; Nolan, S.; Okumura, A.; Ross, D.; Rulten, C.; Schmoll, J.; Schoorlemmer, H.; Stephan, M.; Sutcliffe, P.; Tajima, H.; Thornhill, J.; Tibaldo, L.; Varner, G.; Watson, J.; Zink, A.

    2015-01-01

    The Gamma Cherenkov Telescope (GCT) is proposed to be part of the Small Size Telescope (SST) array of the Cherenkov Telescope Array (CTA). The GCT dual-mirror optical design allows the use of a compact camera of diameter roughly 0.4 m. The curved focal plane is equipped with 2048 pixels of ~0.2{\\deg} angular size, resulting in a field of view of ~9{\\deg}. The GCT camera is designed to record the flashes of Cherenkov light from electromagnetic cascades, which last only a few tens of nanoseconds. Modules based on custom ASICs provide the required fast electronics, facilitating sampling and digitisation as well as first level of triggering. The first GCT camera prototype is currently being commissioned in the UK. On-telescope tests are planned later this year. Here we give a detailed description of the camera prototype and present recent progress with testing and commissioning.

  7. Constraints on Lorentz violation from gravitational Cherenkov radiation

    CERN Document Server

    Kostelecky, Alan

    2015-01-01

    Limits on gravitational Cherenkov radiation by cosmic rays are obtained and used to constrain coefficients for Lorentz violation in the gravity sector associated with operators of even mass dimensions, including orientation-dependent effects. We use existing data from cosmic-ray telescopes to obtain conservative two-sided constraints on 80 distinct Lorentz-violating operators of dimensions four, six, and eight, along with conservative one-sided constraints on three others. Existing limits on the nine minimal operators at dimension four are improved by factors of up to a billion, while 74 of our explicit limits represent stringent first constraints on nonminimal operators. Prospects are discussed for future analyses incorporating effects of Lorentz violation in the matter sector, the role of gravitational Cherenkov radiation by high-energy photons, data from gravitational-wave observatories, the tired-light effect, and electromagnetic Cherenkov radiation by gravitons.

  8. Lunar Imaging and Ionospheric Calibration for the Lunar Cherenkov Technique

    CERN Document Server

    McFadden, Rebecca; Mevius, Maaijke

    2013-01-01

    The Lunar Cherenkov technique is a promising method for UHE neutrino and cosmic ray detection which aims to detect nanosecond radio pulses produced during particle interactions in the Lunar regolith. For low frequency experiments, such as NuMoon, the frequency dependent dispersive effect of the ionosphere is an important experimental concern as it reduces the pulse amplitude and subsequent chances of detection. We are continuing to investigate a new method to calibrate the dispersive effect of the ionosphere on lunar Cherenkov pulses via Faraday rotation measurements of the Moon's polarised emission combined with geomagnetic field models. We also extend this work to include radio imaging of the Lunar surface, which provides information on the physical and chemical properties of the lunar surface that may affect experimental strategies for the lunar Cherenkov technique.

  9. The GCT camera for the Cherenkov Telescope Array

    CERN Document Server

    Brown, Anthony M; Allan, D; Amans, J P; Armstrong, T P; Balzer, A; Berge, D; Boisson, C; Bousquet, J -J; Bryan, M; Buchholtz, G; Chadwick, P M; Costantini, H; Cotter, G; Daniel, M K; De Franco, A; De Frondat, F; Dournaux, J -L; Dumas, D; Fasola, G; Funk, S; Gironnet, J; Graham, J A; Greenshaw, T; Hervet, O; Hidaka, N; Hinton, J A; Huet, J -M; Jegouzo, I; Jogler, T; Kraus, M; Lapington, J S; Laporte, P; Lefaucheur, J; Markoff, S; Melse, T; Mohrmann, L; Molyneux, P; Nolan, S J; Okumura, A; Osborne, J P; Parsons, R D; Rosen, S; Ross, D; Rowell, G; Sato, Y; Sayede, F; Schmoll, J; Schoorlemmer, H; Servillat, M; Sol, H; Stamatescu, V; Stephan, M; Stuik, R; Sykes, J; Tajima, H; Thornhill, J; Tibaldo, L; Trichard, C; Vink, J; Watson, J J; White, R; Yamane, N; Zech, A; Zink, A; Zorn, J

    2016-01-01

    The Gamma-ray Cherenkov Telescope (GCT) is proposed for the Small-Sized Telescope component of the Cherenkov Telescope Array (CTA). GCT's dual-mirror Schwarzschild-Couder (SC) optical system allows the use of a compact camera with small form-factor photosensors. The GCT camera is ~0.4 m in diameter and has 2048 pixels; each pixel has a ~0.2 degree angular size, resulting in a wide field-of-view. The design of the GCT camera is high performance at low cost, with the camera housing 32 front-end electronics modules providing full waveform information for all of the camera's 2048 pixels. The first GCT camera prototype, CHEC-M, was commissioned during 2015, culminating in the first Cherenkov images recorded by a SC telescope and the first light of a CTA prototype. In this contribution we give a detailed description of the GCT camera and present preliminary results from CHEC-M's commissioning.

  10. GAW (Gamma Air Watch) a novel imaging Cherenkov telescope

    CERN Document Server

    Cusumano, G; Biondo, B; Catalano, O; Giarrusso, S; Gugliotta, G; La Fata, L; Maccarone, M C; Mangano, A; Mineo, T; Russo, F; Sacco, B

    2001-01-01

    GAW (Gamma Air Watch) is a new imaging Cherenkov telescope designed for observation of very high-energy gamma-ray sources. GAW will be equipped with a 3 meter diameter Fresnel lens as light collector and with an array of 300 multi-anode photomultipliers at the focal plane. The pixel size will be 4 arcmin wide for a total field of view of 10.5 degrees. Whith respect to the planned imaging Cherenkov telescopes (CANGAROO III, HESS, MAGIC, VERITAS) GAW follows a different approach for what concerns both the optical system and the detection working mode: the Cherenkov light collector is a single acrylic flat Fresnel lens (instead of mirrors) that allows to achieve wide field of view; the photomultipliers operate in single photoelectron counting mode (instead of charge integration). The single photoelectron counting mode allows to reach a low energy threshold of ~200 GeV, in spite of the relatively small dimension of the GAW optic system.

  11. Cherenkov and Scintillation Light Separation in Organic Liquid Scintillators

    CERN Document Server

    Caravaca, J; Land, B J; Yeh, M; Gann, G D Orebi

    2016-01-01

    The CHErenkov / Scintillation Separation experiment (CHESS) has been used to demonstrate the separation of Cherenkov and scintillation light in both linear alkylbenzene (LAB) and LAB with 2g/L of PPO as a fluor (LAB/PPO). This is the first such demonstration for the more challenging LAB/PPO cocktail and improves on previous results for LAB. A time resolution of 338 +/- 12 ps FWHM results in an efficiency for identifying Cherenkov photons in LAB/PPO of 70 +/- 3% and 63 +/- 8% for time- and charge-based separation, respectively, with scintillation contamination of 36 +/- 5% and 38 +/- 4%. LAB/PPO data is consistent with a rise time of 0.75 +/- 0.25 ns.

  12. Lorentz-invariant formulation of Cherenkov radiation by tachyons

    Science.gov (United States)

    Jones, F. C.

    1972-01-01

    Previous treatments of Cherenkov radiation, electromagnetic and gravitational, by tachyons were in error because the prescription employed to cut off the divergent integral over frequency is not a Lorentz invariant procedure. The resulting equation of motion for the tachyon is therefore not covariant. The proper procedure requires an extended, deformable distribution of charge or mass and yields a particularly simple form for the tachyon's world line, one that could be deduced from simple invariance considerations. It is shown that Cherenkov radiation by tachyons implys their ultimate annihilation with an antitachyon and demonstrates a disturbing property of tachyons, namely the impossibility of specifying arbitrary Cauchy data even in a purely classical theory.

  13. Counting Extra Dimensions Magnetic Cherenkov Radiation from High Energy Neutrinos

    CERN Document Server

    Domokos, Gabor K; Kövesi-Domokos, S; Erdas, Andrea

    2003-01-01

    In theories which require a space of dimension d > 4, there is a natural mechanism of suppressing neutrino masses: while Standard Model fields are confined to a 3-brane, right handed neutrinos live in the bulk. Due to Kaluza-Klein excitations, the effective magnetic moments of neutrinos are enhanced. The effective magnetic moment is a monotonically growing function of the energy of the neutrino: consequently, high energy neutrinos can emit observable amounts of magnetic Cherenkov radiation. By observing the energy dependence of the magnetic Cherenkov radiation, one may be able to determine the number of compactified dimensions.

  14. Light Sensor Candidates for the Cherenkov Telescope Array

    CERN Document Server

    Knoetig, M L; Kurz, M; Hose, J; Lorenz, E; Schweizer, T; Teshima, M; Buzhan, P; Popova, E; Bolmont, J; Tavernet, J -P; Vincent, P; Shayduk, M

    2011-01-01

    We report on the characterization of candidate light sensors for use in the next-generation Imaging Atmospheric Cherenkov Telescope project called Cherenkov Telescope Array, a major astro-particle physics project of about 100 telescopes that is currently in the prototyping phase. Our goal is to develop with the manufacturers the best possible light sensors (highest photon detection efficiency, lowest crosstalk and afterpulsing). The cameras of those telescopes will be based on classical super-bi-alkali Photomultiplier tubes but also Silicon Photomultipliers are candidate light sensors. A full characterisation of selected sensors was done. We are working in close contact with several manufacturers, giving them feedback and suggesting improvements.

  15. Gain of double-slab Cherenkov free-electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Li, D. [Institute for laser Technology, suita, Osaka 565-0871 (Japan)], E-mail: dazhi_li@hotmail.com; Huo, G. [Petroleum development center, Shengli Oilfield, SINOPEC, Dongying 257001 (China); Imasak, K. [Institute for laser Technology, suita, Osaka 565-0871 (Japan); Asakawa, M. [Department of pure and applied physics, Faculty of Engineering Science, Kansai University, Osaka 564-8680 (Japan)

    2009-07-21

    A formula is derived for the small-signal gain of a double-slab Cherenkov free-electron laser. The simplified model is composed of a rectangular wave-guide partially filled with two lined parallel dielectric slabs and a sheet electron beam. The theory describes the electron beam as a plasma dielectric moving between the two dielectric slabs. With the help of hydrodynamic approximation, we derived the dispersion equation and the formula of small-signal gain. Through numerical computing, we studied an ongoing experiment of double-slab Cherenkov free-electron laser, and worked out the synchronous frequency and single-pass gain.

  16. The CLEO-III RICH Detector and Beam Test Results

    CERN Document Server

    Wang, J C; Ayad, R; Azfar, F; Dambasuren, E; Efimov, A; Kopp, S E; Majumder, G; Mountain, R; Schuh, S; Skwarnicki, T; Stone, S; Viehhauser, G; Anderson, S; Smith, A; Kubota, Y; Lipeles, E; Coan, T E; Staeck, J; Fadeev, V; Volobuev, I P

    1999-01-01

    We are constructing a Ring Imaging Cherenkov detector (RICH) for the CLEO III upgrade for precision charged hadron identification. The RICH uses plane and sawtooth LiF crystals as radiators, MWPCs as photon detectors with TEA as the photo-sensitive material, and low-noise Viking readout electronics. Results of a beam test of the first two out of total 30 sectors are presented.

  17. A disc-DIRC for experiments at WASA and as a test detector for PANDA

    Energy Technology Data Exchange (ETDEWEB)

    Doroshkevich, Evgueny [Physikalisches Institut, Univ. Tuebingen (Germany); Collaboration: WASA-at-COSY-Collaboration

    2012-07-01

    For a precise measurement of the velocity of highly relativistic particles the detection of Cherenkov light is very attractive. Detectors based on the Detection of Internally Reflected Cherenkov Light (DIRC) - first built and used in the BaBar experiment - are also planned for the PANDA detector at FAIR, both in form of a barrel-DIRC and in form of a disc-DIRC. In both cases the Cherenkov rings are reconstructed from the internally reflected Cherenkov light deflected into position sensitive detectors. For the WASA Forward Detector setup a Disc-DIRC quarter has been built, which serves both as a test module for PANDA and an important upgrade of the WASA. For an optimal performance at WASA the Disc-DIRC-Quarter is tilted by 20 {sup circle} out of the vertical plane. The internally reflected Cherenkov light is guided to multi-anode photomultipliers by focussing light guides, which are made of plexiglass, i.e. the same material the radiator is made of. Results from first tests in the COSY beam are reported.

  18. AtmoHEAD 2013 workshop / Atmospheric Monitoring for High-Energy Astroparticle Detectors

    CERN Document Server

    Bernlöhr, K; Blanch, O; Bourgeat, M; Bruno, P; Buscemi, M; Cassardo, C; Chadwick, P M; Chalme-Calvet, R; Chouza, F; Cilmo, M; Coco, M; Colombi, J; Compin, M; Daniel, M K; Reyes, R De Los; Ebr, J; D'Elia, R; Deil, C; Etchegoyen, A; Doro, M; Ferrarese, S; Fiorini, M; Font, LL; Garrido, D; Gast, H; Gaug, M; Gonzales, F; Grillo, A; Guarino, F; Hahn, J; Hrabovsky, M; Kosack, K; Krüger, P; La Rosa, G; Leto, G; Lo, Y T E; López-Oramas, A; Louedec, K; Maccarone, M C; Mandat, D; Marandon, V; Martinetti, E; Martinez, M; de Naurois, M; Neronov, A; Nolan, S J; Otero, L; Palatka, M; Pallotta, J; Pech, M; Puhlhofer, G; Prouza, M; Quel, E; Raul, D; Ristori, P; Frias, M D Rodriguez; Rivoire, S; Rulten, C B; Schovanek, P; Segreto, A; Sottile, G; Stringhetti, L; Tavernet, J -P; Tonachini, A S; Toscano, S; Travnicek, P; Valore, L; Vasileiadis, G; Vincent, S; Wada, S; Wiencke, L; Will, M

    2014-01-01

    A 3-day international workshop on atmospheric monitoring and calibration for high-energy astroparticle detectors, with a view towards next-generation facilities. The atmosphere is an integral component of many high-energy astroparticle detectors. Imaging atmospheric Cherenkov telescopes and cosmic-ray extensive air shower detectors are the two instruments driving the rapidly evolving fields of very-high- and ultra-high-energy astrophysics. In these instruments, the atmosphere is used as a giant calorimeter where cosmic rays and gamma rays deposit their energy and initiate EASs; it is also the medium through which the resulting Cherenkov light propagates. Uncertainties in real-time atmospheric conditions and in the fixed atmospheric models typically dominate all other systematic errors. With the improved sensitivity of upgraded IACTs such as H.E.S.S.-II and MAGIC-II and future facilities like the Cherenkov Telescope Array (CTA) and JEM-EUSO, statistical uncertainties are expected to be significantly reduced, l...

  19. Lunar imaging and ionospheric calibration for the Lunar Cherenkov technique

    NARCIS (Netherlands)

    McFadden, R.; Scholten, O.; Mevius, M.

    2013-01-01

    The Lunar Cherenkov technique is a promising method for UHE neutrino and cosmic ray detection which aims to detect nanosecond radio pulses produced during particle interactions in the Lunar regolith. For low frequency experiments, such as NuMoon, the frequency dependent dispersive effect of the iono

  20. The ARCADE Raman Lidar System for the Cherenkov Telescope Array

    CERN Document Server

    Valore, Laura; Doro, Michele; Iarlori, Marco; Rizi, Vincenzo; Tonachini, Aurelio Siro; Vallania, Piero

    2015-01-01

    The Cherenkov Telescope Array (CTA) is the next generation of ground-based very high energy gamma-ray instruments; the facility will be organized in two arrays, one for each hemisphere. The atmospheric calibration of the CTA telescopes is a critical task. The atmosphere affects the measured Cherenkov yield in several ways: the air-shower development itself, the variation of the Cherenkov angle with altitude, the loss of photons due to scattering and absorption of Cherenkov light out of the camera field-of-view and the scattering of photons into the camera. In this scenario, aerosols are the most variable atmospheric component in time and space and therefore need a continuous monitoring. Lidars are among the most used instruments in atmospheric physics to measure the aerosol attenuation profiles of light. The ARCADE Lidar system is a very compact and portable Raman Lidar system that has been built within the FIRB 2010 grant and is currently taking data in Lamar, Colorado. The ARCADE Lidar is proposed to operat...

  1. Suppressing the Numerical Cherenkov Instability in FDTD PIC Codes

    CERN Document Server

    Godfrey, Brendan B

    2014-01-01

    A procedure for largely suppressing the numerical Cherenkov instability in finite difference time-domain (FDTD) particle-in-cell (PIC) simulations of cold, relativistic beams is derived, and residual growth rates computed and compared with WARP code simulation results. Sample laser-plasma acceleration simulation output is provided to further validate the new procedure.

  2. Surface detector array for the Pierre Auger observatory

    Science.gov (United States)

    Salazar, H.; Garipov, G. K.; Khrenov, B. A.; Martínez, O.; Moreno, E.; Villaseñor, L.; Zepeda, A.

    2001-05-01

    The Pierre Auger international collaboration will install two observatories, one in the southern hemisphere and other in the northern hemisphere. Each observatory will consist of two different subsystem: a surface detector array of about 1600 water Cherenkov detectors (WCD) and a set of fluorescence eyes to measure the longitudinal development of air showers. The large area covered by the surface detectors requires efficient calibration and monitoring methods that can be implemented remotely. We present several complementary methods to calibrate and monitor the performance of the individual surface detector stations. We also present some results of the studies made with a full size prototype tank in Puebla, Mexico and in Malargue, Argentina. .

  3. Mrk 421, Mrk 501, and 1ES 1426+428 at 100 GeV with the CELESTE Cherenkov Telescope

    CERN Document Server

    Smith, D A; Britto, R; Bruel, P; Gordo, J B; Dumora, D; Durand, E; Eschstruth, P; Espigat, P; Holder, J; Jacholkowska, A; Lavalle, J; Le Gallou, R; Lott, B; Manseri, H; Munz, F; Nuss, E; Piron, Frédéric; Reposeur, T; Sako, T

    2006-01-01

    We have measured the gamma-ray fluxes of the blazars Mrk 421 and Mrk 501 in the energy range between 50 and 350 GeV (1.2 to 8.3 x 10^25 Hz). The detector, called CELESTE, used first 40, then 53 heliostats of the former solar facility "Themis" in the French Pyrenees to collect Cherenkov light generated in atmospheric particle cascades. The signal from Mrk 421 is often strong. We compare its flux with previously published multi-wavelength studies and infer that we are straddling the high energy peak of the spectral energy distribution. The signal from Mrk 501 in 2000 was weak (3.4 sigma). We obtain an upper limit on the flux from 1ES 1426+428 of less than half that of the Crab flux near 100 GeV. The data analysis and understanding of systematic biases have improved compared to previous work, increasing the detector's sensitivity.

  4. First results of the two square meters multilayer glass composite mirror design proposed for the Cherenkov Telescope Array developed at INFN

    CERN Document Server

    Schultz, C; Lessio, L; Mariotti, M; Rando, R

    2015-01-01

    The Cherenkov Telescope Array (CTA) is a future ground-based gamma-ray astronomy detector that will consist of more than 100 Imaging Atmospheric Cherenkov Telescopes of different sizes. The total reflective surface of roughly 10 000 m$^2$ requires unprecedented technological efforts towards a cost-efficient production of light-weight and reliable mirror substrates at high production rate. We report on a new mirror concept proposed for CTA developed by INFN, which is based on the replication from a spherical convex mold under low pressure. The mirror substrate is an open structure design made by thin glass layers at the mirror's front and rear interspaced by steel cylinders. A first series of nominal size mirrors has been produced, for which we discuss the optical properties in terms of radius of curvature and focusing power.

  5. Evaluation of the optical cross talk level in the SiPMs adopted in ASTRI SST-2M Cherenkov Camera using EASIROC front-end electronics

    CERN Document Server

    Impiombato, D; Mineo, T; Agnetta, G; Biondo, B; Catalano, O; Gargano, C; La Rosa, G; Russo, F; Sottile, G; Belluso, M; Billotta, S; Bonanno, G; Garozzo, S; Marano, D; Romeo, G

    2013-01-01

    ASTRI (Astrofisica con Specchi a Tecnologia Replicante Italiana), is a flagship project of the Italian Ministry of Education, University and Research whose main goal is the design and construction of an end-to-end prototype of the Small Size of Telescopes of the Cherenkov Telescope Array. The prototype, named ASTRI SST-2M, will adopt a wide field dual mirror optical system in a Schwarzschild-Couder configuration to explore the VHE range of the electromagnetic spectrum. The camera at the focal plane is based on Silicon Photo-Multipliers detectors which is an innovative solution for the detection astronomical Cherenkov light. This contribution reports some preliminary results on the evaluation of the optical cross talk level among the SiPM pixels foreseen for the ASTRI SST-2M camera.

  6. First detector installed inside the ALICE solenoid...

    CERN Multimedia

    2006-01-01

    ALICE's emblematic red magnet welcomed its first detector on 23 September, when the array of seven Cherenkov detectors, named HMPID, was successfully installed. ALICE team members standing in front of the completed HMPID detector.The red magnet, viewed from its front opening. The HMPID unit, seen from the back (top right corner of photo) is placed on a frame and lifted onto a platform during the installation. After the installation of the ACORDE scintillator array and the muon trigger and tracking chambers, the ALICE collaboration fitted the first detector inside the solenoid. The HMPID, for High Momentum Particle Identification, was installed at the 2 o'clock position in the central and most external region of the space frame, just below the solenoid yoke. It will be used to extend the hadron identification capability of the ALICE experiment up to 5 GeV/c, thus complementing the reach of the other particle identification systems (ITS, TPC and TOF). The HMPID is a Ring Imaging Cherenkov (RICH) detector in a...

  7. Radium-228 analysis of natural waters by Cherenkov counting of Actinium-228

    Energy Technology Data Exchange (ETDEWEB)

    Aleissa, Khalid A.; Almasoud, Fahad I.; Islam, Mohammed S. [Atomic Energy Research Institute, King Abdul Aziz City for Science and Technology, P.O. Box 6086, Riyadh 11442 (Saudi Arabia); L' Annunziata, Michael F. [IAEA Expert, Montague Group, P.O. Box 5033, Oceanside, CA 92052-5033 (United States)], E-mail: mlannunziata@cox.net

    2008-12-15

    The activities of {sup 228}Ra in natural waters were determined by the Cherenkov counting of the daughter nuclide {sup 228}Ac. The radium was pre-concentrated on MnO{sub 2} and the radium purified via ion exchange and, after a 2-day period of incubation to allow for secular equilibrium between the parent-daughter {sup 228}Ra({sup 228}Ac), the daughter nuclide {sup 228}Ac was isolated by ion exchange according to the method of Nour et al. [2004. Radium-228 determination of natural waters via concentration on manganese dioxide and separation using Diphonix ion exchange resin. Appl. Radiat. Isot. 61, 1173-1178]. The Cherenkov photons produced by {sup 228}Ac were counted directly without the addition of any scintillation reagents. The optimum Cherenkov counting window, sample volume, and vial type were determined experimentally to achieve optimum Cherenkov photon detection efficiency and lowest background count rates. An optimum detection efficiency of 10.9{+-}0.1% was measured for {sup 228}Ac by Cherenkov counting with a very low Cherenkov photon background of 0.317{+-}0.013 cpm. The addition of sodium salicylate into the sample counting vial at a concentration of 0.1 g/mL yielded a more than 3-fold increase in the Cherenkov detection efficiency of {sup 228}Ac to 38%. Tests of the Cherenkov counting technique were conducted with several water standards of known activity and the results obtained compared closely with a conventional liquid scintillation counting technique. The advantages and disadvantages of Cherenkov counting compared to liquid scintillation counting methods are discussed. Advantages include much lower Cherenkov background count rates and consequently lower minimal detectable activities for {sup 228}Ra and no need for expensive environmentally unfriendly liquid scintillation cocktails. The disadvantages of the Cherenkov counting method include the need to measure {sup 228}Ac Cherenkov photon detection efficiency and optimum Cherenkov counting volume

  8. Radium-228 analysis of natural waters by Cherenkov counting of Actinium-228.

    Science.gov (United States)

    Aleissa, Khalid A; Almasoud, Fahad I; Islam, Mohammed S; L'Annunziata, Michael F

    2008-12-01

    The activities of (228)Ra in natural waters were determined by the Cherenkov counting of the daughter nuclide (228)Ac. The radium was pre-concentrated on MnO(2) and the radium purified via ion exchange and, after a 2-day period of incubation to allow for secular equilibrium between the parent-daughter (228)Ra((228)Ac), the daughter nuclide (228)Ac was isolated by ion exchange according to the method of Nour et al. [2004. Radium-228 determination of natural waters via concentration on manganese dioxide and separation using Diphonix ion exchange resin. Appl. Radiat. Isot. 61, 1173-1178]. The Cherenkov photons produced by (228)Ac were counted directly without the addition of any scintillation reagents. The optimum Cherenkov counting window, sample volume, and vial type were determined experimentally to achieve optimum Cherenkov photon detection efficiency and lowest background count rates. An optimum detection efficiency of 10.9+/-0.1% was measured for (228)Ac by Cherenkov counting with a very low Cherenkov photon background of 0.317+/-0.013cpm. The addition of sodium salicylate into the sample counting vial at a concentration of 0.1g/mL yielded a more than 3-fold increase in the Cherenkov detection efficiency of (228)Ac to 38%. Tests of the Cherenkov counting technique were conducted with several water standards of known activity and the results obtained compared closely with a conventional liquid scintillation counting technique. The advantages and disadvantages of Cherenkov counting compared to liquid scintillation counting methods are discussed. Advantages include much lower Cherenkov background count rates and consequently lower minimal detectable activities for (228)Ra and no need for expensive environmentally unfriendly liquid scintillation cocktails. The disadvantages of the Cherenkov counting method include the need to measure (228)Ac Cherenkov photon detection efficiency and optimum Cherenkov counting volume, which are not at all required when liquid

  9. The Technical Performance of the HEGRA System of Imaging Air Cherenkov Telescopes

    CERN Document Server

    Pühlhofer, G; Götting, N; Heusler, A; Horns, D; Kohnle, A; Lampeitl, H; Panter, M; Tluczykont, M; Aharonian, F A; Akhperjanian, A G; Beilicke, M; Bernlöhr, K; Borst, H G; Bojahr, H; Coarasa, T; Contreras, J L; Cortina, J; Denninghoff, S; Fonseca, M V; Girma, M; Heinzelmann, G; Hermann, G; Hofmann, W; Jung, I; Kankanyan, R; Kestel, M; Konopelko, A; Kornmeyer, H; Kranich, D; López, M; Lorenz, E; Lucarelli, F; Mang, O; Meyer, H; Mirzoyan, R; Moralejo, A; Oña-Wilhelmi, E; Plyasheshnikov, A V; De los Reyes, R; Rhode, W; Ripken, J; Rowell, G; Sahakian, V V; Samorski, M; Schilling, M; Siems, M; Sobzynska, D; Stamm, W; Vitale, V; Völk, H J; Wiedner, C A

    2003-01-01

    Between early 1997 and late 2002, the HEGRA collaboration operated a stereoscopic system of 4 (later 5) imaging atmospheric Cherenkov telescopes. In this paper we present the calibration schemes which were developed for the system, and report on the performance of the detector over the years. In general, the telescope system was very well understood, regarding both the absolute calibration and the slight changes in performance over the years. The system had an energy threshold of 500 GeV for observations at zenith and under optimum detector conditions. With the corresponding calibration schemes, a systematic accuracy of 15 percent on the absolute energy scale has been achieved. The continuous sensitivity monitoring provided a relative accuracy of a few percent, and showed that the threshold did not exceed 600 GeV throughout the entire operation time. The readout electronics and the imaging quality of the dishes were well monitored and stable. The absolute pointing had an accuracy of at least 25 arcsec; this n...

  10. Software Development for Ring Imaging Detector

    Science.gov (United States)

    Torisky, Benjamin

    2016-03-01

    Jefferson Lab (Jlab) is performing a large-scale upgrade to their Continuous Electron Beam Accelerator Facility (CEBAF) up to 12GeV beam. The Large Acceptance Spectrometer (CLAS12) in Hall B is being upgraded and a new Ring Imaging Cherenkov (RICH) detector is being developed to provide better kaon - pion separation throughout the 3 to 12 GeV range. With this addition, when the electron beam hits the target, the resulting pions, kaons, and other particles will pass through a wall of translucent aerogel tiles and create Cherenkov radiation. This light can then be accurately detected by a large array of Multi-Anode PhotoMultiplier Tubes (MA-PMT). I am presenting an update on my work on the implementation of Java based reconstruction programs for the RICH in the CLAS12 main analysis package.

  11. An Analog Trigger System for Atmospheric Cherenkov Telescopes

    CERN Document Server

    Barcelo, M; Bigas, O Blanch; Boix, J; Delgado, C; Herranz, D; Lopez-Coto, R; Martinez, G

    2013-01-01

    Arrays of Cherenkov telescopes typically use multi-level trigger schemes to keep the rate of random triggers from the night sky background low. At a first stage, individual telescopes produce a trigger signal from the pixel information in the telescope camera. The final event trigger is then formed by combining trigger signals from several telescopes. In this poster, we present a possible scheme for the Cherenkov Telescope Array telescope trigger, which is based on the analog pulse information of the pixels in a telescope camera. Advanced versions of all components of the system have been produced and working prototypes have been tested, showing a performance that meets the original specifications. Finally, issues related to integrating the trigger system in a telescope camera and in the whole array will be dealt with.

  12. Normalized and Asynchronous Mirror Alignment for Cherenkov Telescopes

    CERN Document Server

    Ahnen, M L; Balbo, M; Bergmann, M; Biland, A; Blank, M; Bretz, T; Bruegge, K A; Buss, J; Domke, M; Dorner, D; Einecke, S; Hempfling, C; Hildebrand, D; Hughes, G; Lustermann, W; Mannheim, K; Mueller, S A; Neise, D; Neronov, A; Noethe, M; Overkemping, A -K; Paravac, A; Pauss, F; Rhode, W; Shukla, A; Temme, F; Thaele, J; Toscano, S; Vogler, P; Walter, R; Wilbert, A

    2016-01-01

    Imaging Atmospheric Cherenkov Telescopes (IACTs) need imaging optics with large apertures and high image intensities to map the faint Cherenkov light emitted from cosmic ray air showers onto their image sensors. Segmented reflectors fulfill these needs, and as they are composed from mass production mirror facets they are inexpensive and lightweight. However, as the overall image is a superposition of the individual facet images, alignment is a challenge. Here we present a computer vision based star tracking alignment method, which also works for limited or changing star light visibility. Our method normalizes the mirror facet reflection intensities to become independent of the reference star's intensity or the cloud coverage. Using two CCD cameras, our method records the mirror facet orientations asynchronously of the telescope drive system, and thus makes the method easy to integrate into existing telescopes. It can be combined with remote facet actuation, but does not require one to work. Furthermore, it ca...

  13. G-APDs in Cherenkov astronomy: The FACT camera

    Energy Technology Data Exchange (ETDEWEB)

    Kraehenbuehl, T., E-mail: thomas.kraehenbuehl@phys.ethz.ch [ETH Zurich, Institute for Particle Physics, CH-8093 Zurich (Switzerland); Anderhub, H. [ETH Zurich, Institute for Particle Physics, CH-8093 Zurich (Switzerland); Backes, M. [Technische Universitaet Dortmund, D-44221 Dortmund (Germany); Biland, A.; Boller, A.; Braun, I. [ETH Zurich, Institute for Particle Physics, CH-8093 Zurich (Switzerland); Bretz, T. [Ecole Polytechnique Federale de Lausanne, CH-1015 Lausanne (Switzerland); Commichau, V.; Djambazov, L. [ETH Zurich, Institute for Particle Physics, CH-8093 Zurich (Switzerland); Dorner, D.; Farnier, C. [ISDC Data Center for Astrophysics, CH-1290 Versoix (Switzerland); Gendotti, A.; Grimm, O.; Gunten, H. von; Hildebrand, D.; Horisberger, U.; Huber, B.; Kim, K.-S. [ETH Zurich, Institute for Particle Physics, CH-8093 Zurich (Switzerland); Koehne, J.-H.; Krumm, B. [Technische Universitaet Dortmund, D-44221 Dortmund (Germany); and others

    2012-12-11

    Geiger-mode avalanche photodiodes (G-APD, SiPM) are a much discussed alternative to photomultiplier tubes in Cherenkov astronomy. The First G-APD Cherenkov Telescope (FACT) collaboration builds a camera based on a hexagonal array of 1440 G-APDs and has now finalized its construction phase. A light-collecting solid PMMA cone is glued to each G-APD to eliminate dead space between the G-APDs by increasing the active area, and to restrict the light collection angle of the sensor to the reflector area in order to reduce the amount of background light. The processing of the signals is integrated in the camera and includes the digitization using the domino ring sampling chip DRS4.

  14. Silicon Photomultiplier Camera for Schwarzschild-Couder Cherenkov Telescopes

    CERN Document Server

    Vandenbroucke, J

    2014-01-01

    The Cherenkov Telescope Array (CTA) is an atmospheric Cherenkov observatory that will image the cosmos in very-high-energy gamma rays. CTA will study the highest-energy particle accelerators in the Universe and potentially confirm the particle nature of dark matter. We have designed an innovative Schwarzschild-Couder telescope which uses two mirrors to achieve excellent optical performance across a wide field of view. The small plate scale of the dual-mirror optics enables a compact camera which uses modern technology including silicon photomultipliers and the TARGET application-specific integrated circuit to read out a finely pixelated focal plane of 11,328 channels with modest weight, volume, cost, and power consumption. The camera design is hierarchical and modular at each level, enabling robust construction, operation, and maintenance. A prototype telescope is under construction and will be commissioned at the VERITAS site in Arizona. An array of such telescopes will provide excellent angular resolution a...

  15. Cherenkov loss factor of short relativistic bunches:general approach

    CERN Document Server

    Baturin, S S

    2013-01-01

    The interaction of short relativistic charged particle bunches with waveguides and other accelerator system components is a critical issue for the development of X-ray FELs (free electron lasers) and linear collider projects. Wakefield Cherenkov losses of short bunches have been studied previously for resistive wall, disk-loaded, corrugated and dielectric loaded waveguides. It was noted in various publications [1] that if the slowdown layer is thin, the Cherenkov loss factor of a short bunch does not depend on the guiding system material and is a constant for any given transverse cross section dimensions of the waveguides. In this paper, we consider a new approach to the analysis of loss factors for relativistic short bunches and formulate a general integral relation that allows calculation of the loss factor for a short relativistic bunch passing an arbitrary waveguide system. The loss factors calculated by this new method for various types of waveguides with arbitrary thickness slowdown layers, including in...

  16. Optical Cherenkov radiation in ultrafast cascaded second-harmonic generation

    DEFF Research Database (Denmark)

    Bache, Morten; Bang, Ole; Zhou, Binbin

    2010-01-01

    the dispersive wave. Finally, an investigation of recent experimental results uncovers a four-wave-mixing phenomenon related to Cherenkov radiation that is an additional generation mechanism of long-wavelength radiation that can occur during soliton compression. We discuss the conditions that lead......We show through theory and numerics that when few-cycle femtosecond solitons are generated through cascaded (phase-mismatched) second-harmonic generation, these broadband solitons can emit optical Cherenkov radiation in the form of linear dispersive waves located in the red part of the spectrum....... The beating between the dispersive wave and the soliton generates trailing temporal oscillations on the compressed soliton. Insertion of a simple short-wave pass filter after the crystal can restore a clean soliton. On the other hand, bandpass filtering around the dispersive wave peak results in near...

  17. PyFACT: Python and FITS analysis for Cherenkov telescopes

    Science.gov (United States)

    Raue, Martin; Deil, Christoph

    2012-12-01

    Ground-based very-high energy (VHE; E>100 GeV) gamma-ray astronomy is growing from being conducted by small teams in closed collaborations into a full-fledged branch of astronomy with open observatories. This is best illustrated by the number of known sources: it increased by one order of magnitude in the past ten years, from 10 in the year 2000 to more than 100 in 2010. It is expected that this trend will continue with the next-generation instrument Cherenkov Telescope Array (CTA). This transformation has a profound impact on the data format and analysis of Imaging Atmospheric Cherenkov Telescopes (IACTs). Up to now, IACT data analysis was an internal task performed by specialists with no public access to the data or software. In the future, a large community of VHE astronomers from different scientific topics should be enabled to work with the data. Ease of use, compatibility, and integration with existing astronomy standards and tools will be key. In this contribution, a collection of Python tools for the analysis of data in FITS format (PyFACT; Python and FITS Analysis for Cherenkov Telescopes) is presented, which connects with existing tools like xspec, sherpa, and ds9. The package is available as open source (https://github.com/mraue/pyfact, comments and contributions welcome). Advantages of the chosen ansatz are discussed and implications for future observatories and data archival are presented.

  18. Normalized and asynchronous mirror alignment for Cherenkov telescopes

    Science.gov (United States)

    Ahnen, M. L.; Baack, D.; Balbo, M.; Bergmann, M.; Biland, A.; Blank, M.; Bretz, T.; Bruegge, K. A.; Buss, J.; Domke, M.; Dorner, D.; Einecke, S.; Hempfling, C.; Hildebrand, D.; Hughes, G.; Lustermann, W.; Mannheim, K.; Mueller, S. A.; Neise, D.; Neronov, A.; Noethe, M.; Overkemping, A.-K.; Paravac, A.; Pauss, F.; Rhode, W.; Shukla, A.; Temme, F.; Thaele, J.; Toscano, S.; Vogler, P.; Walter, R.; Wilbert, A.

    2016-09-01

    Imaging Atmospheric Cherenkov Telescopes (IACTs) need imaging optics with large apertures and high image intensities to map the faint Cherenkov light emitted from cosmic ray air showers onto their image sensors. Segmented reflectors fulfill these needs, and as they are composed from mass production mirror facets they are inexpensive and lightweight. However, as the overall image is a superposition of the individual facet images, alignment is a challenge. Here we present a computer vision based star tracking alignment method, which also works for limited or changing star light visibility. Our method normalizes the mirror facet reflection intensities to become independent of the reference star's intensity or the cloud coverage. Using two CCD cameras, our method records the mirror facet orientations asynchronously of the telescope drive system, and thus makes the method easy to integrate into existing telescopes. It can be combined with remote facet actuation, but does not require one to work. Furthermore, it can reconstruct all individual mirror facet point spread functions without moving any mirror. We present alignment results on the 4 m First Geiger-mode Avalanche Cherenkov Telescope (FACT).

  19. Cherenkov Telescopes Results on Pulsar Wind Nebulae and Pulsars

    Science.gov (United States)

    Wilhelmi, Emma De Oña

    The last few years have seen a revolution in very high γ-ray astronomy (VHE; E>100 GeV) driven largely by a new generation of Cherenkov telescopes. These new facilities, namely H.E.S.S. (High Energy Stereoscopic System), MAGIC (Major Atmospheric Gamma Imaging Cherenkov Telescope) and its upgrade MAGIC 2, VERITAS (Very Energetic Radiation Imaging Telescope Array System) and CANGAROO (Collaboration of Australia and Nippon for a Gamma Ray Observatory in the Outback) were designed to increase the flux sensitivity in the energy regime of hundreds of GeV, expanding the observed energy range from 50 to multi-TeV, and fostered as a result a period of rapid growth in our understanding of the Non-ThermalUniverse. As a result of this fast development the number of pulsar wind nebulae (PWNe) detected has increased from a few in the early 90's to more than two dozen of firm candidates nowadays. Also, the low energy threshold achieved allows to investigate the pulsed spectra of the high energy pulsars powering PWNe. A review of the most relevant VHE results concerning pulsars and their relativistic winds is discussed here in the context of Cherenkov telescopes.

  20. The RICH detector for CLAS12 at Jefferson Lab

    Directory of Open Access Journals (Sweden)

    Pappalardo L.L.

    2014-06-01

    Full Text Available The CLAS12 spectrometer at JLab will offer unique possibilities to study the 3D nucleon structure in terms of TMDs and GPDs in the poorly explored valence region, and to perform high precision hadron spectroscopy. A large area ring-imaging Cherenkov detector has been designed to achieve the required hadron identification capability in the momentum range 3–8 GeV/c. The detector, based on a novel hybrid imaging design, foresees an aerogel radiator and an array of multi-anode photomultipliers. The detector concept and preliminary results of test-beams on a prototype are presented.

  1. Applications of Cherenkov Light Emission for Dosimetry in Radiation Therapy

    Science.gov (United States)

    Glaser, Adam Kenneth

    Since its discovery in the 1930's, the Cherenkov effect has been paramount in the development of high-energy physics research. It results in light emission from charged particles traveling faster than the local speed of light in a dielectric medium. The ability of this emitted light to describe a charged particle's trajectory, energy, velocity, and mass has allowed scientists to study subatomic particles, detect neutrinos, and explore the properties of interstellar matter. However, only recently has the phenomenon been considered in the practical context of medical physics and radiation therapy dosimetry, where Cherenkov light is induced by clinical x-ray photon, electron, and proton beams. To investigate the relationship between this phenomenon and dose deposition, a Monte Carlo plug-in was developed within the Geant4 architecture for medically-oriented simulations (GAMOS) to simulate radiation-induced optical emission in biological media. Using this simulation framework, it was determined that Cherenkov light emission may be well suited for radiation dosimetry of clinically used x-ray photon beams. To advance this application, several novel techniques were implemented to realize the maximum potential of the signal, such as time-gating for maximizing the signal to noise ratio (SNR) and Cherenkov-excited fluorescence for generating isotropic light release in water. Proof of concept experiments were conducted in water tanks to demonstrate the feasibility of the proposed method for two-dimensional (2D) projection imaging, three-dimensional (3D) parallel beam tomography, large field of view 3D cone beam tomography, and video-rate dynamic imaging of treatment plans for a number of common radiotherapy applications. The proposed dosimetry method was found to have a number of unique advantages, including but not limited to its non-invasive nature, water-equivalence, speed, high-resolution, ability to provide full 3D data, and potential to yield data in-vivo. Based on

  2. Development of a SiPM Camera for a Schwarzschild-Couder Cherenkov Telescope for the Cherenkov Telescope Array

    CERN Document Server

    Otte, A N; Dickinson, H.; Funk, S.; Jogler, T.; Johnson, C.A.; Karn, P.; Meagher, K.; Naoya, H.; Nguyen, T.; Okumura, A.; Santander, M.; Sapozhnikov, L.; Stier, A.; Tajima, H.; Tibaldo, L.; Vandenbroucke, J.; Wakely, S.; Weinstein, A.; Williams, D.A.

    2015-01-01

    We present the development of a novel 11328 pixel silicon photomultiplier (SiPM) camera for use with a ground-based Cherenkov telescope with Schwarzschild-Couder optics as a possible medium-sized telescope for the Cherenkov Telescope Array (CTA). The finely pixelated camera samples air-shower images with more than twice the optical resolution of cameras that are used in current Cherenkov telescopes. Advantages of the higher resolution will be a better event reconstruction yielding improved background suppression and angular resolution of the reconstructed gamma-ray events, which is crucial in morphology studies of, for example, Galactic particle accelerators and the search for gamma-ray halos around extragalactic sources. Packing such a large number of pixels into an area of only half a square meter and having a fast readout directly attached to the back of the sensors is a challenging task. For the prototype camera development, SiPMs from Hamamatsu with through silicon via (TSV) technology are used. We give ...

  3. The software architecture of the camera for the ASTRI SST-2M prototype for the Cherenkov Telescope Array

    Science.gov (United States)

    Sangiorgi, Pierluca; Capalbi, Milvia; Gimenes, Renato; La Rosa, Giovanni; Russo, Francesco; Segreto, Alberto; Sottile, Giuseppe; Catalano, Osvaldo

    2016-07-01

    The purpose of this contribution is to present the current status of the software architecture of the ASTRI SST-2M Cherenkov Camera. The ASTRI SST-2M telescope is an end-to-end prototype for the Small Size Telescope of the Cherenkov Telescope Array. The ASTRI camera is an innovative instrument based on SiPM detectors and has several internal hardware components. In this contribution we will give a brief description of the hardware components of the camera of the ASTRI SST-2M prototype and of their interconnections. Then we will present the outcome of the software architectural design process that we carried out in order to identify the main structural components of the camera software system and the relationships among them. We will analyze the architectural model that describes how the camera software is organized as a set of communicating blocks. Finally, we will show where these blocks are deployed in the hardware components and how they interact. We will describe in some detail, the physical communication ports and external ancillary devices management, the high precision time-tag management, the fast data collection and the fast data exchange between different camera subsystems, and the interfacing with the external systems.

  4. The Electronics and Data Acquisition System for the DarkSide-50 Veto Detectors

    CERN Document Server

    Agnes, P; Albuquerque, I F M; Alexander, T; Alton, A K; Arisaka, K; Back, H O; Baldin, B; Biery, K; Bonfini, G; Bossa, M; Bottino, B; Brigatti, A; Brodsky, J; Budano, F; Bussino, S; Cadeddu, M; Cadoni, M; Calaprice, F; Canci, N; Candela, A; Cao, H; Cariello, M; Carlini, M; Catalanotti, S; Cavalcante, P; Chepurnov, A; Cocco, A G; Covone, G; Crippa, L; D'Angelo, D; D'Incecco, M; Davini, S; De Cecco, S; De Deo, M; De Vincenzi, M; Derbin, A; Devoto, A; Di Eusanio, F; Di Pietro, G; Edkins, E; Empl, A; Fan, A; Fiorillo, G; Fomenko, K; Foster, G; Franco, D; Gabriele, F; Galbiati, C; Giganti, C; Goretti, A M; Granato, F; Grandi, L; Gromov, M; Guan, M; Guardincerri, Y; Hackett, B R; Herner, K R; Hungerford, E V; Ianni, Aldo; Ianni, Andrea; James, I; Jollet, C; Keeter, K; Kendziora, C L; Kobychev, V; Koh, G; Korablev, D; Korga, G; Kubankin, A; Li, X; Lissia, M; Lombardi, P; Luitz, S; Ma, Y; Machulin, I N; Mandarano, A; Mari, S M; Maricic, J; Marini, L; Martoff, C J; Meregaglia, A; Meyers, P D; Miletic, T; Milincic, R; Montanari, D; Monte, A; Montuschi, M; Monzani, M E; Mosteiro, P; Mount, B J; Muratova, V N; Musico, P; Napolitano, J; Nelson, A; Odrowski, S; Orsini, M; Ortica, F; Pagani, L; Pallavicini, M; Pantic, E; Parmeggiano, S; Pelczar, K; Pelliccia, N; Pocar, A; Pordes, S; Pugachev, D A; Qian, H; Randle, K; Ranucci, G; Razeto, A; Reinhold, B; Renshaw, A L; Riffard, Q; Romani, A; Rossi, B; Rossi, N; Rountree, S D; Sablone, D; Saggese, P; Saldanha, R; Sands, W; Sangiorgio, S; Savarese, C; Segreto, E; Semenov, D A; Shields, E; Singh, P N; Skorokhvatov, M D; Smirnov, O; Sotnikov, A; Stanford, C; Suvorov, Y; Tartaglia, R; Tatarowicz, J; Testera, G; Tonazzo, A; Trinchese, P; Unzhakov, E V; Vishneva, A; Vogelaar, R B; Wada, M; Walker, S; Wang, H; Wang, Y; Watson, A W; Westerdale, S; Wilhelmi, J; Wojcik, M M; Xiang, X; Xu, J; Yang, C; Yoo, J; Zavatarelli, S; Zec, A; Zhong, W; Zhu, C; Zuzel, G

    2016-01-01

    DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles (WIMPs). It utilizes a liquid argon time projection chamber (LAr TPC) for the inner main detector. The TPC is surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV, both instrumented with PMTs, act as the neutron and cosmogenic muon veto detectors for DarkSide-50. This paper describes the electronics and data acquisition system used for these two detectors.

  5. Characterization of a 6×6-mm{sup 2} 75-μm cell MPPC suitable for the Cherenkov Telescope Array project

    Energy Technology Data Exchange (ETDEWEB)

    Romeo, G., E-mail: giuseppe.romeo@oact.inaf.it [INAF, Osservatorio Astrofisico di Catania, Via S. Sofia 78, I-95123 Catania (Italy); Bonanno, G.; Garozzo, S.; Grillo, A.; Marano, D.; Munari, M.; Timpanaro, M.C. [INAF, Osservatorio Astrofisico di Catania, Via S. Sofia 78, I-95123 Catania (Italy); Catalano, O.; Giarrusso, S.; Impiombato, D.; La Rosa, G.; Sottile, G. [INAF, Istituto di Astrofisica Spaziale e Fisica cosmica di Palermo, Via U. La Malfa 153, I-90146 Palermo (Italy)

    2016-08-01

    This paper presents the latest characterization results of a novel Low Cross-Talk (LCT) large-area (6×6-mm{sup 2}) Multi-Pixel Photon Counter (MPPC) detector manufactured by Hamamatsu, belonging to the recent LCT5 family and achieving a fill-factor enhancement and cross-talk reduction. In addition, the newly adopted resin coating is demonstrated to yield improved photon detection capabilities in the 290–350 nm spectral range, making the new LCT MPPC particularly suitable for emerging applications like Cherenkov Telescopes. For a 3×3-mm{sup 2} version of the new MPPC under test, a comparative analysis of the large pixel pitch (75-µm) detector versus the smaller pixel pitch (50-µm) detector is also undertaken. Furthermore, measurements of the 6×6-mm{sup 2} MPPC response versus the angle of incidence are provided for the characterized device.

  6. Velocity and charge reconstruction with the AMS/RICH detector

    CERN Document Server

    Arruda, Luísa; Borges, João; Carmo, Fernando; Gonçalves, Patrícia; Pimenta, Mário

    2008-01-01

    The Alpha Magnetic Spectrometer (AMS), to be installed on the International Space Station (ISS) in 2008, will be equipped with a proximity focusing Ring Imaging CHerenkov detector (RICH). This detector will be equipped with a dual radiator (aerogel+NaF), a lateral conical mirror and a detection plane made of 680 photomultipliers and light-guides, enabling measurements of particle electric charge and velocity. A likelihood method for the Cherenkov angle reconstruction was applied leading to a velocity determination for protons with a resolution around 0.1%. The electric charge reconstruction is based on the counting of the number of photoelectrons and on an overall efficiency estimation on an event-by-event basis. Results from the application of both methods are presented.

  7. Single photon light detector for deep ocean applications

    Energy Technology Data Exchange (ETDEWEB)

    Matsuno, S.; Babson, J.; Learned, J.G.; O' Connor, D.; Grieder, P.K.F.; Kitamura, T.; Mitsui, K.; Ohashi, Y.; Okada, A.; Clem, J.

    1989-03-15

    We have developed a single photon sensitive light detector module which can be operated in the ocean to a depth of 5000 m. It was designed primarily to be used as a Cherenkov light detector in conjunction with the DUMAND (Deep Underwater Muon And Neutrino Detector) experiment. After calibration in the laboratory, seven detectors, assembled in a vertical string geometry, have been operated simultaneously in the deep ocean off the coast of the island of Hawaii. Cosmic ray muons have been recorded successfully at dephts ranging from 2000 to 4000 m. The results have demonstrated the capability of the detector; it fulfills the specifications required for the modules to be used in a deep ocean muon and neutrino detector.

  8. Single photon light detector for deep ocean applications

    Science.gov (United States)

    Matsuno, S.; Babson, J.; Learned, J. G.; O'Connor, D.; Grieder, P. K. F.; Kitamura, T.; Mitsui, K.; Ohashi, Y.; Okada, A.; Clem, J.; Webster, M.; Wilson, C.

    1989-03-01

    We have developed a single photon sensitive light detector module which can be operated in the ocean to a depth of 5000 m. It was designed primarily to be used as a Cherenkov light detector in conjunction with the DUMAND (Deep Underwater Muon And Neutrino Detector) experiment. After calibration in the laboratory, seven detectors, assembled in a vertical string geometry, have been operated simultaneously in the deep ocean off the coast of the island of Hawaii. Cosmic ray muons have been recorded successfully at depths ranging from 2000 to 4000 m. The results have demonstrated the capability of the detector; it fulfills the specifications required for the modules to be used in a deep ocean muon and neutrino detector.

  9. Towards a large scale high energy cosmic neutrino undersea detector

    Energy Technology Data Exchange (ETDEWEB)

    Azoulay, R.; Berthier, R. [CEA Centre d`Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France). Direction des Sciences de la Matiere; Arpesella, C. [Centre National de la Recherche Scientifique (CNRS), 13 - Marseille (France). Centre de Physique Theorique] [and others

    1997-06-01

    ANTARES collaboration proposes to study high energy cosmic neutrinos by using a deep sea Cherenkov detector. The potential interest of such a study for astrophysicists and particle physicists is developed. The different origins of cosmic neutrinos are reviewed. In order to observe with relevant statistic the flux of neutrinos from extra-galactic sources, a km-scale detector is necessary. The feasibility of such a detector is studied. A variety of technical problems have been solved. Some of them are standard for particle physicists: choice of photo-multipliers, monitoring, trigger, electronics, data acquisition, detector optimization. Others are more specific of sea science engineering particularly: detector deployment in deep sea, data transmission through optical cables, bio-fouling, effect of sea current. The solutions are presented and the sea engineering part involving detector installation will be tested near French coasts. It is scheduled to build a reduced-scale demonstrator within the next 2 years. (A.C.) 50 refs.

  10. Detectors and flux instrumentation for future neutrino facilities

    CERN Document Server

    Abe, T; Andreopoulos, C; Ankowski, A; Badertscher, A; Battistoni, G; Blondel, A; Bouchez, J; Bross, A; Bueno, A; Camilleri, L; Campagne, Jean-Eric; Cazes, A; Cervera-Villanueva, A; De Lellis, G; Di Capua, F; Ellis, Malcolm; Ereditato, A; Esposito, L S; Fukushima, C; Gschwendtner, E; Gomez-Cadenas, J J; Iwasaki, M; Kaneyuki, K; Karadzhov, Y; Kashikhin, V; Kawai, Y; Komatsu, M; Kozlovskaya, E; Kudenko, Y; Kusaka, A; Kyushima, H; Longhin, A; Marchionni, A; Marotta, A; McGrew, C; Menary, S; Meregaglia, A; Mezzeto, M; Migliozzi, P; Mondal, N K; Montanari, C; Nakadaira, T; Nakamura, M; Nakumo, H; Nakayama, H; Nelson, J; Nowak, J; Ogawa, S; Peltoniemi, J; Pla-Dalmau, A; Ragazzi, S; Rubbia, A; Sanchez, F; Sarkamo, J; Sato, O; Selvi, M; Shibuya, H; Shozawa, M; Sobczyk, J; Soler, F J P; Strolin, Paolo Emilio; Suyama, M; Tanak, M; Terranova, F; Tsenov, R; Uchida, Y; Weber, A; Zlobin, A

    2009-01-01

    This report summarises the conclusions from the detector group of the International Scoping Study of a future Neutrino Factory and Super-Beam neutrino facility. The baseline detector options for each possible neutrino beam are defined as follows: 1. A very massive (Megaton) water Cherenkov detector is the baseline option for a sub-GeV Beta Beam and Super Beam facility. 2. There are a number of possibilities for either a Beta Beam or Super Beam (SB) medium energy facility between 1-5 GeV. These include a totally active scintillating detector (TASD), a liquid argon TPC or a water Cherenkov detector. 3. A 100 kton magnetized iron neutrino detector (MIND) is the baseline to detect the wrong sign muon final states (golden channel) at a high energy (20-50 GeV) neutrino factory from muon decay. A 10 kton hybrid neutrino magnetic emulsion cloud chamber detector for wrong sign tau detection (silver channel) is a possible complement to MIND, if one needs to resolve degeneracies that appear in the $\\delta$-$\\theta_{13}$...

  11. Cherenkov counting efficiencies for {beta}{sup -}-emitters in dry state in glass vials

    Energy Technology Data Exchange (ETDEWEB)

    Morita-Murase, Yuko; Murakami, Isao; Homma, Yoshio [Laboratory for Radiopharmaceutical Chemistry, Kyoritsu College of Pharmacy, Tokyo (Japan)

    2000-10-01

    Cherenkov counting efficiencies for standardized {beta}{sup -} -emitters in the dry state at the centre of air-filled glass vials were measured with a liquid scintillation spectrometer. Cherenkov counting efficiencies, which are plotted as a function of the average energy of {beta}{sup -}-particles and the internal conversion electrons, give a straight line on log-log scale. (author)

  12. Fast Timing Detector R&D for Forward Proton Detectors at LHC

    Science.gov (United States)

    Snyder, Christina

    2017-01-01

    Quartz Timing Cherenkov (QUARTIC) detectors were tested at Fermilab Test Beam Facility in order to determine the timing resolution of very forward protons from collisions at the Large Hadron Collider (LHC). The active media of the detectors are quartz and sapphire, which are radiation hard and high light-yield materials. These detectors are constructed of 20 L-shaped bars that enable one to differentiate and detect more than one proton from the same LHC bunch crossing. The QUARTIC detectors have a small active area of 4cm2, which is well-matched to the acceptance of the scattered protons. Our experimental results will be presented and further testing of this design is planned.

  13. Development of the Solar Tower Atmospheric Cherenkov Effect Experiment (STACEE)

    CERN Document Server

    Ong, R A

    1998-01-01

    STACEE is a proposed atmospheric Cherenkov telescope for ground-based gamma-ray astrophysics between 25 and 500 GeV. The telescope will make use of the large solar mirrors (heliostats) available at a solar research facility to achieve an energy threshold lower than any existing ground-based instrument. This paper describes the development of STACEE, including an overview of the complete instrument design and a discussion of results from recent prototype tests at the large solar heliostat field of Sandia National Laboratories.

  14. CELESTE an atmospheric Cherenkov telescope for high energy gamma astrophysics

    CERN Document Server

    Paré, E; Bazer-Bachi, R; Bergeret, H; Berny, F; Briand, N; Bruel, P; Cerutti, M; Collon, J; Cordier, A; Cornebise, P; Debiais, G; Dezalay, J P; Dumora, D; Durand, E; Eschstruth, P T; Espigat, P; Fabre, B; Fleury, P; Gilly, J; Gouillaud, J C; Gregory, C; Herault, N; Holder, J; Hrabovsky, M; Incerti, S; Jouenne, A; Kalt, L; Legallou, R; Lott, B; Lodygensky, O; Manigot, P; Manseri, H; Manitaz, H; Martin, M; Morano, R; Morineaud, G; Muenz, F; Musquere, A; Naurois, M D; Neveu, J; Noppe, J M; Olive, J F; Palatka, M; Pérez, A; Quebert, J; Rebii, A; Reposeur, T; Rob, L; Roy, P; Sans, J L; Sako, T; Schovanek, P; Smith, D A; Snabre, P; Villard, G

    2002-01-01

    CELESTE is an atmospheric Cherenkov telescope based on the sampling method which makes use of the de-commissioned THEMIS solar electrical plant in the French Pyrenees. A large (2000 m sup 2) mirror surface area from 40 independent heliostats followed by a secondary optic, a trigger system using analog summing techniques and signal digitization with 1 GHz flash ADCs make possible the detection of cosmic gamma-rays down to 30 GeV. This paper provides a detailed technical description of the CELESTE installation.

  15. Relativistic Cherenkov radiation in a magneto-dielectric media

    Directory of Open Access Journals (Sweden)

    2016-09-01

    Full Text Available In this paper, relativistic Cherenkov radiation was studied in a 3-D magneto-dielectric medium. Electric permittivity and magnetic permeability of the medium as functions of frequency, are assumed to satisfy Kramers- Kronig equations. A new interaction Hamiltonian, which is different from Hamiltonian term in non-relativistic state, was introduced by the quantized vector potential field and particle field operator obtained from the second quantization method. The rate of electron energy dissipation was calculated using Fermi’s golden rule.

  16. First scientific contributions from the High Altitude Water Cherenkov Observatory

    Science.gov (United States)

    León Vargas, H.; HAWC Collaboration

    2015-09-01

    The High Altitude Water Cherenkov Observatory (HAWC), located at the slopes of the volcanoes Sierra Negra and Pico de Orizaba in Mexico, was inaugurated on March 20, 2015. However, data taking started in August 2013 with a partially deployed observatory and since then the instrument has collected data as it got closer to its final configuration. HAWC is a ground based TeV gamma-ray observatory with a large field of view that will be used to study the Northern sky with high sensitivity. In this contribution we present some of the results obtained with the partially built instrument and the expected capabilities to detect different phenomena with the complete observatory.

  17. Modified energy-momentum conservation laws and vacuum Cherenkov radiation

    CERN Document Server

    Carmona, J M; Romeo, B

    2014-01-01

    We present a general parametrization for the leading order terms in a momentum power expansion of a non-universal Lorentz-violating, but rotational invariant, kinematics and its implications for two-body decay thresholds. The considered framework includes not only modified dispersion relations for particles, but also modified energy-momentum conservation laws, something which goes beyond effective field theory. As a particular and relevant example, bounds on the departures from special relativistic kinematics from the non-observation of vacuum Cherenkov radiation are discussed and compared with those obtained within the effective field theory scenario.

  18. Control Software for the VERITAS Cherenkov Telescope System

    CERN Document Server

    Krawczynski, H; Sembroski, G; Gibbs, K

    2003-01-01

    The VERITAS collaboration is developing a system of initially 4 and eventually 7 Cherenkov Telescopes of the 12 m diameter class for high sensitivity gamma-ray astronomy in the >50 GeV energy range. In this contribution we describe the software that controls and monitors the various VERITAS sub-systems. The software uses an object-oriented approach to cope with the complexities that arise from using sub-groups of the 7 VERITAS telescopes to observe several sources at the same time. Inter-process communication is based on the CORBA Object Request Broker protocol and watch-dog processes monitor the sub-system performance.

  19. Corrugated capillary as THz Cherenkov Smith-Purcell radiator

    Science.gov (United States)

    Lekomtsev, K. V.; Aryshev, A. S.; Tishchenko, A. A.; Ponomarenko, A. A.; Sukharev, V. M.; Terunuma, N.; Urakawa, J.; Strikhanov, M. N.

    2016-07-01

    In this article we discussed Particle In Cell electromagnetic simulations and mechanical design of dielectric capillaries that produce THz Cherenkov Smith-Purcell radiation (ChSPR), arising when a femtosecond electron multi-bunch beam propagates through corrugated and non-corrugated dielectric capillaries with metallic radiation reflectors. We investigated the influence of the four-bunch beam on the SPR field spectrum and on the ChSPR power spectrum, and the influence of the non-central beam propagation on the ChSPR power spectrum. We also discussed the design and assembly of the capillaries, constructed as sets of cylindrical rings.

  20. Study of Cherenkov light lateral distribution function around the knee region in extensive air showers

    Directory of Open Access Journals (Sweden)

    Al-Rubaiee A.

    2015-01-01

    Full Text Available The Cherenkov light lateral distribution function (LDF was simulated with the CORSIKAcode in the energy range (1013 - 1016 eV. This simulation was performed for conditions and configurations of the Tunka EAS Cherenkov array for the two primary particles (p and Fe. Basing on the simulated results, many approximated functions are structured for two primary particles and different zenith angles. This allowed us to reconstruct the EAS events, which is, to determine the type and energy of the primary particles that produced showers from signal amplitudes of Cherenkov radiation measured by the Tunka Cherenkov array experiment. Comparison of the calculated LDF of Cherenkov radiation with that measured at the Tunka EAS array shows the ability to identify the primary particle that initiated the EAS cascades by determining its primary energy around the knee region of the cosmic ray spectrum.

  1. Study of Cherenkov Light Lateral Distribution Function around the Knee Region in Extensive Air Showers

    CERN Document Server

    Al-Rubaiee, A A; M., Marwah; Al-Douri, Y

    2015-01-01

    The Cherenkov light lateral distribution function (LDF) was simulated with the CORSIKA code, in the energy range (10^13-10^16) eV. This simulation was performed for conditions and configurations of the Tunka EAS Cherenkov array for two primary particles (p and Fe). Basing on the simulated results, many approximated functions are structured for two primary particles and different zenith angles. This allowed us to reconstruct the EAS events, which is, to determine the type and energy of the primary particles that produced showers from signal amplitudes of Cherenkov radiation which measured with Tunka Cherenkov array experiment. Comparison of the calculated LDF of Cherenkov radiation with that measured at the Tunka EAS array shows the ability for identifying of the primary particle that initiated the EAS cascades determining of its primary energy around the knee region of the cosmic ray spectrum.

  2. The ASTRI mini-array within the future Cherenkov Telescope Array

    CERN Document Server

    Vercellone, Stefano

    2015-01-01

    The Cherenkov Telescope Array (CTA) is a large collaborative effort aimed at the design and operation of an observatory dedicated to very high-energy gamma-ray astrophysics in the energy range from a few tens of GeV to above 100 TeV, which will yield about an order of magnitude improvement in sensitivity with respect to the current major arrays (H.E.S.S., MAGIC, and VERITAS). Within this framework, the Italian National Institute for Astrophysics is leading the ASTRI project, whose main goals are the design and installation on Mt. Etna (Sicily) of an end-to-end dual-mirror prototype of the CTA small size telescope (SST) and the installation at the CTA Southern site of a dual-mirror SST mini-array composed of nine units with a relative distance of about 300 m. The innovative dual-mirror Schwarzschild-Couder optical solution adopted for the ASTRI Project allows us to substantially reduce the telescope plate-scale and, therefore, to adopt silicon photo-multipliers as light detectors. The ASTRI mini-array is a wid...

  3. FACT - The First G-APD Cherenkov Telescope: Status and Results

    CERN Document Server

    Bretz, T; Backes, M; Biland, A; Boccone, V; Braun, I; Bretz, T; Buss, J; Cadoux, F; Commichau, V; Djambazov, L; Dorner, D; Einecke, S; Eisenacher, D; Gendotti, A; Grimm, O; von Gunten, H; Haller, C; Hildebrand, D; Horisberger, U; Huber, B; Kim, K -S; Knoetig, M L; Koehne, J -H; Kraehenbuehl, T; Krumm, B; Lee, M; Lorenz, E; Lustermann, W; Lyard, E; Mannheim, K; Meharga, M; Meier, K; Montaruli, T; Neise, D; Nessi-Tedaldi, F; Overkemping, A -K; Paravac, A; Pauss, F; Renker, D; Rhode, W; Ribordy, M; Roeser, U; Stucki, J -P; Schneider, J; Steinbring, T; Temme, F; Thaele, J; Tobler, S; Viertel, G; Vogler, P; Walter, R; Warda, K; Weitzel, Q; Zaenglein, M

    2013-01-01

    The First G-APD Cherenkov telescope (FACT) is the first telescope using silicon photon detectors (G-APD aka. SiPM). It is built on the mount of the HEGRA CT3 telescope, still located at the Observatorio del Roque de los Muchachos, and it is successfully in operation since Oct. 2011. The use of Silicon devices promises a higher photon detection efficiency, more robustness and higher precision than photo-multiplier tubes. The FACT collaboration is investigating with which precision these devices can be operated on the long-term. Currently, the telescope is successfully operated from remote and robotic operation is under development. During the past months of operation, the foreseen monitoring program of the brightest known TeV blazars has been carried out, and first physics results have been obtained including a strong flare of Mrk501. An instantaneous flare alert system is already in a testing phase. This presentation will give an overview of the project and summarize its goals, status and first results.

  4. Measuring TeV cosmic rays at the High Altitude Water Cherenkov Observatory

    Directory of Open Access Journals (Sweden)

    BenZvi Segev

    2015-01-01

    Full Text Available The High-Altitude Water Cherenkov Observatory, or HAWC, is an air shower array designed to observe cosmic rays and gamma rays between 100 GeV and 100 TeV. HAWC, located between the peaks Sierra Negra and Pico de Orizaba in central Mexico, will be completed in the spring of 2015. However, the observatory has been collecting data in a partial configuration since mid-2013. With only part of the final array in data acquisition, HAWC has already accumulated a data set of nearly 100 billion air showers. These events are used to calibrate the detector angular reconstruction using the shadow of the Moon, and to measure the anisotropy in the arrival directions of cosmic rays above 1 TeV. Using data recorded between June 2013 and July 2014, we have observed a significant 10−4 anisotropy consisting of three statistically significant “hotspots” in the cosmic ray flux. We will discuss these first results from HAWC and compare them to previous measurements of anisotropy in the northern and southern sky.

  5. Measuring TeV cosmic rays at the High Altitude Water Cherenkov Observatory

    Science.gov (United States)

    BenZvi, Segev

    2015-12-01

    The High-Altitude Water Cherenkov Observatory, or HAWC, is an air shower array designed to observe cosmic rays and gamma rays between 100 GeV and 100 TeV. HAWC, located between the peaks Sierra Negra and Pico de Orizaba in central Mexico, will be completed in the spring of 2015. However, the observatory has been collecting data in a partial configuration since mid-2013. With only part of the final array in data acquisition, HAWC has already accumulated a data set of nearly 100 billion air showers. These events are used to calibrate the detector angular reconstruction using the shadow of the Moon, and to measure the anisotropy in the arrival directions of cosmic rays above 1 TeV. Using data recorded between June 2013 and July 2014, we have observed a significant 10-4 anisotropy consisting of three statistically significant "hotspots" in the cosmic ray flux. We will discuss these first results from HAWC and compare them to previous measurements of anisotropy in the northern and southern sky.

  6. Solar tower atmospheric Cherenkov effect experiment (STACEE) for ground based gamma ray astronomy

    Science.gov (United States)

    Bhattacharya, D.; Chantell, M. C.; Coppi, P.; Covault, C. E.; Dragovan, M.; Gregorich, D. T.; Hanna, D. S.; Mukherjee, R.; Ong, R. A.; Oser, S.; Ragan, K.; Tümer, O. T.; Williams, D. A.

    1997-05-01

    The STACEE experiment is being developed to study very high energy astrophysical gamma rays between 50 and 500 GeV. During the last few years this previously unexplored region has received much attention due to the detection of sources up to about 10 GeV by the EGRET instrument on board the CGRO. However, the paucity of detected sources at ~1 TeV indicates that fundamental processes working within these sources and/or in the intergalactic space are responsible for the cutoff in the photon spectra of the EGRET sources. The cutoff or the spectral change of these sources can be observed with ground-based Cherenkov detectors with a very low threshold. The use of large arrays of mirrors at solar power facilities is a promising way of lowering the threshold. Using this concept a series of tests were conducted at the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (Albuquerque, NM) with a full size prototype of the STACEE telescope system. The tests show that STACEE will be capable of meaningful exploration of the gamma-ray sky between 50 and 500 GeV with good sensitivity.

  7. The COMPASS RICH-1 detector upgrade

    CERN Document Server

    Abbon, P; Angerer, H; Apollonio, M; Birsa, R; Bordalo, P; Bradamante, F; Bressan, A; Busso, L; Chiosso, M; Ciliberti, P; Colantoni, M L; Costa, S; Dalla Torre, S; Dafni, T; Delagnes, E; Deschamps, H; Díaz, V; Dibiase, N; Duic, V; Eyrich, W; Faso, D; Ferrero, A; Finger, M; Finger, M Jr; Fischer, H; Gerassimov, S; Giorgi, M; Gobbo, B; Hagemann, R; Von Harrach, D; Heinsius, F H; Joosten, R; Ketzer, B; Königsmann, K C; Kolosov, V N; Konorov, I; Kramer, Daniel; Kunne, F; Lehmann, A; Levorato, S; Maggiora, A; Magnon, A; Mann, A; Martin, A; Menon, G; Mutter, A; Nähle, O; Nerling, F; Neyret, D; Pagano, P; Panebianco, S; Panzieri, D; Paul, S; Pesaro, G; Polak, J; Rebourgeard, P; Robinet, F; Rocco, E; Schiavon, P; Schill, C; Schröder, W; Silva, L; Slunecka, M; Sozzi, F; Steiger, L; Sulc, M; Svec, M; Tessarotto, F; Teufel, A; Wollny, H

    2008-01-01

    The COMPASS experiment at CERN provides hadron identification in a wide momentum range employing a large size gaseous Ring Imaging CHerenkov detector (RICH). The presence of large uncorrelated background in the COMPASS environment was limiting the efficiency of COMPASS RICH-1 in the very forward regime. A major upgrade of RICH-1 required a new technique for Cherenkov photon detection at count rates of several 10$^{6}$/s per channel in the central detector part, and a read-out system allowing for trigger rates of up to 100 kHz. To cope with these requirements, the photon detectors of the central region have been replaced with a fast photon detection system described here, while, in the peripheral regions, the existing multi-wire proportional chambers with CsI photo-cathodes have been equipped with a new read-out system based on APV preamplifiers and flash ADC chips. The new system consists of multi-anode photomultiplier tubes (MAPMTs) coupled to individual fused silica lens telescopes, and fast read-out electr...

  8. Optical properties studies of glass samples for prototyping a TORCH detector module

    CERN Multimedia

    Castillo García, L

    2014-01-01

    TORCH (Time Of internally Reflected CHerenkov light) ) is a proposed particle identification system to achieve positive π/K/p separation at a ≥3σ level in the momentum range below 10 GeV/c. Cherenkov photons are generated from charged particle tracks crossing a 1cm-thick quartz plate. They propagate by total internal reflection to the edge and are focused onto an array of micro-channel plate photon detectors. Their position and arrival time are recorded. This allows the reconstruction of the photon trajectory and the particle crossing time. Results on optical tests are presented.

  9. A Compact High Energy Camera for the Cherenkov Telescope Array

    CERN Document Server

    Daniel, M K; Berge, D; Buckley, J; Chadwick, P M; Cotter, G; Funk, S; Greenshaw, T; Hidaka, N; Hinton, J; Lapington, J; Markoff, S; Moore, P; Nolan, S; Ohm, S; Okumura, A; Ross, D; Sapozhnikov, L; Schmoll, J; Sutcliffe, P; Sykes, J; Tajima, H; Varner, G S; Vandenbroucke, J; Vink, J; Williams, D

    2013-01-01

    The Compact High Energy Camera (CHEC) is a camera-development project involving UK, US, Japanese and Dutch institutes for the dual-mirror Small-Sized Telescopes (SST-2M) of the Cherenkov Telescope Array (CTA). Two CHEC prototypes, based on different photosensors are funded and will be assembled and tested in the UK over the next ~18 months. CHEC is designed to record flashes of Cherenkov light lasting from a few to a hundred nanoseconds, with typical RMS image width and length of ~0.2 x 1.0 degrees, and has a 9 degree field of view. The physical camera geometry is dictated by the telescope optics: a curved focal surface with radius of curvature 1m and diameter ~35cm is required. CHEC is designed to work with both the ASTRI and GATE SST-2M telescope structures and will include an internal LED flasher system for calibration. The first CHEC prototype will be based on multi-anode photomultipliers (MAPMs) and the second on silicon photomultipliers (SiPMs or MPPCs). The first prototype will soon be installed on the...

  10. INFN Camera demonstrator for the Cherenkov Telescope Array

    CERN Document Server

    Ambrosi, G; Aramo, C.; Bertucci, B.; Bissaldi, E.; Bitossi, M.; Brasolin, S.; Busetto, G.; Carosi, R.; Catalanotti, S.; Ciocci, M.A.; Consoletti, R.; Da Vela, P.; Dazzi, F.; De Angelis, A.; De Lotto, B.; de Palma, F.; Desiante, R.; Di Girolamo, T.; Di Giulio, C.; Doro, M.; D'Urso, D.; Ferraro, G.; Ferrarotto, F.; Gargano, F.; Giglietto, N.; Giordano, F.; Giraudo, G.; Iacovacci, M.; Ionica, M.; Iori, M.; Longo, F.; Mariotti, M.; Mastroianni, S.; Minuti, M.; Morselli, A.; Paoletti, R.; Pauletta, G.; Rando, R.; Fernandez, G. Rodriguez; Rugliancich, A.; Simone, D.; Stella, C.; Tonachini, A.; Vallania, P.; Valore, L.; Vagelli, V.; Verzi, V.; Vigorito, C.

    2015-01-01

    The Cherenkov Telescope Array is a world-wide project for a new generation of ground-based Cherenkov telescopes of the Imaging class with the aim of exploring the highest energy region of the electromagnetic spectrum. With two planned arrays, one for each hemisphere, it will guarantee a good sky coverage in the energy range from a few tens of GeV to hundreds of TeV, with improved angular resolution and a sensitivity in the TeV energy region better by one order of magnitude than the currently operating arrays. In order to cover this wide energy range, three different telescope types are envisaged, with different mirror sizes and focal plane features. In particular, for the highest energies a possible design is a dual-mirror Schwarzschild-Couder optical scheme, with a compact focal plane. A silicon photomultiplier (SiPM) based camera is being proposed as a solution to match the dimensions of the pixel (angular size of ~ 0.17 degrees). INFN is developing a camera demonstrator made by 9 Photo Sensor Modules (PSMs...

  11. Upgraded cameras for the HESS imaging atmospheric Cherenkov telescopes

    Science.gov (United States)

    Giavitto, Gianluca; Ashton, Terry; Balzer, Arnim; Berge, David; Brun, Francois; Chaminade, Thomas; Delagnes, Eric; Fontaine, Gérard; Füßling, Matthias; Giebels, Berrie; Glicenstein, Jean-François; Gräber, Tobias; Hinton, James; Jahnke, Albert; Klepser, Stefan; Kossatz, Marko; Kretzschmann, Axel; Lefranc, Valentin; Leich, Holger; Lüdecke, Hartmut; Lypova, Iryna; Manigot, Pascal; Marandon, Vincent; Moulin, Emmanuel; de Naurois, Mathieu; Nayman, Patrick; Penno, Marek; Ross, Duncan; Salek, David; Schade, Markus; Schwab, Thomas; Simoni, Rachel; Stegmann, Christian; Steppa, Constantin; Thornhill, Julian; Toussnel, François

    2016-08-01

    The High Energy Stereoscopic System (H.E.S.S.) is an array of five imaging atmospheric Cherenkov telescopes, sensitive to cosmic gamma rays of energies between 30 GeV and several tens of TeV. Four of them started operations in 2003 and their photomultiplier tube (PMT) cameras are currently undergoing a major upgrade, with the goals of improving the overall performance of the array and reducing the failure rate of the ageing systems. With the exception of the 960 PMTs, all components inside the camera have been replaced: these include the readout and trigger electronics, the power, ventilation and pneumatic systems and the control and data acquisition software. New designs and technical solutions have been introduced: the readout makes use of the NECTAr analog memory chip, which samples and stores the PMT signals and was developed for the Cherenkov Telescope Array (CTA). The control of all hardware subsystems is carried out by an FPGA coupled to an embedded ARM computer, a modular design which has proven to be very fast and reliable. The new camera software is based on modern C++ libraries such as Apache Thrift, ØMQ and Protocol buffers, offering very good performance, robustness, flexibility and ease of development. The first camera was upgraded in 2015, the other three cameras are foreseen to follow in fall 2016. We describe the design, the performance, the results of the tests and the lessons learned from the first upgraded H.E.S.S. camera.

  12. The readout system of the MAGIC-II Cherenkov Telescope

    CERN Document Server

    Tescaro, D; Barcelo, M; Bitossi, M; Cortina, J; Fras, M; Hadasch, D; Illa, J M; Martínez, M; Mazin, D; Paoletti, R; Pegna, R

    2009-01-01

    In this contribution we describe the hardware, firmware and software components of the readout system of the MAGIC-II Cherenkov telescope on the Canary island La Palma. The PMT analog signals are transmitted by means of optical fibers from the MAGIC-II camera to the 80 m away counting house where they are routed to the new high bandwidth and fully programmable receiver boards (MONSTER), which convert back the signals from optical to electrical ones. Then the signals are split, one half provide the input signals for the level ONE trigger system while the other half is sent to the digitizing units. The fast Cherenkov pulses are sampled by low-power Domino Ring Sampler chips (DRS2) and temporarily stored in an array of 1024 capacitors. Signals are sampled at the ultra-fast speed of 2 GSample/s, which allows a very precise measurement of the signal arrival times in all pixels. They are then digitized with 12-bit resolution by an external ADC readout at 40 MHz speed. The Domino samplers are integrated in the newly...

  13. Sites in Argentina for the Cherenkov Telescope Array Project

    CERN Document Server

    Allekotte, Ingo; Etchegoyen, Alberto; García, Beatriz; Mancilla, Alexis; Maya, Javier; Ravignani, Diego; Rovero, Adrián

    2013-01-01

    The Cherenkov Telescope Array (CTA) Project will consist of two arrays of atmospheric Cherenkov telescopes to study high-energy gamma radiation in the range of a few tens of GeV to beyond 100 TeV. To achieve full-sky coverage, the construction of one array in each terrestrial hemisphere is considered. Suitable candidate sites are being explored and characterized. The candidate sites in the Southern Hemisphere include two locations in Argentina, one in San Antonio de los Cobres (Salta Province, Lat. 24:02:42 S, Long. 66:14:06 W, at 3600 m.a.s.l) and another one in El Leoncito (San Juan Province, Lat. 31:41:49 S, Long. 69:16:21 W, at 2600 m.a.s.l). Here we describe the two sites and the instrumentation that has been deployed to characterize them. We summarize the geographic, atmospheric and climatic data that have been collected for both of them.

  14. The next generation Cherenkov Telescope Array observatory: CTA

    CERN Document Server

    Vercellone, Stefano

    2014-01-01

    The Cherenkov Telescope Array (CTA) is a large collaborative effort aimed at the design and operation of an observatory dedicated to the VHE gamma-ray astrophysics in the energy range 30 GeV-100 TeV, which will improve by about one order of magnitude the sensitivity with respect to the current major arrays (H.E.S.S., MAGIC, and VERITAS). In order to achieve such improved performance, for both the northern and southern CTA sites, four units of 23m diameter Large Size Telescopes (LSTs) will be deployed close to the centre of the array with telescopes separated by about 100m. A larger number (about 25 units) of 12m Medium Size Telescopes (MSTs, separated by about 150m), will cover a larger area. The southern site will also include up to 24 Schwarzschild-Couder dual-mirror medium-size Telescopes (SCTs) with the primary mirror diameter of 9.5m. Above a few TeV, the Cherenkov light intensity is such that showers can be detected even well outside the light pool by telescopes significantly smaller than the MSTs. To a...

  15. The On-Site Analysis of the Cherenkov Telescope Array

    CERN Document Server

    Bulgarelli, Andrea; Zoli, Andrea; Aboudan, Alessio; Rodríguez-Vázquez, Juan José; De Cesare, Giovanni; De Rosa, Adriano; Maier, Gernot; Lyard, Etienne; Bastieri, Denis; Lombardi, Saverio; Tosti, Gino; Bergamaschi, Sonia; Beneventano, Domenico; Lamanna, Giovanni; Jacquemier, Jean; Kosack, Karl; Antonelli, Lucio Angelo; Boisson, Catherine; Borkowski, Jerzy; Buson, Sara; Carosi, Alessandro; Conforti, Vito; Colomé, Pep; Reyes, Raquel de los; Dumm, Jon; Evans, Phil; Fortson, Lucy; Fuessling, Matthias; Gotz, Diego; Graciani, Ricardo; Gianotti, Fulvio; Grandi, Paola; Hinton, Jim; Humensky, Brian; Inoue, Susumu; Knödlseder, Jürgen; Flour, Thierry Le; Lindemann, Rico; Malaguti, Giuseppe; Markoff, Sera; Marisaldi, Martino; Neyroud, Nadine; Nicastro, Luciano; Ohm, Stefan; Osborne, Julian; Oya, Igor; Rodriguez, Jerome; Rosen, Simon; Ribo, Marc; Tacchini, Alessandro; Schüssler, Fabian; Stolarczyk, Thierry; Torresi, Eleonora; Testa, Vincenzo; Wegner, Peter

    2015-01-01

    The Cherenkov Telescope Array (CTA) observatory will be one of the largest ground-based very high-energy gamma-ray observatories. The On-Site Analysis will be the first CTA scientific analysis of data acquired from the array of telescopes, in both northern and southern sites. The On-Site Analysis will have two pipelines: the Level-A pipeline (also known as Real-Time Analysis, RTA) and the level-B one. The RTA performs data quality monitoring and must be able to issue automated alerts on variable and transient astrophysical sources within 30 seconds from the last acquired Cherenkov event that contributes to the alert, with a sensitivity not worse than the one achieved by the final pipeline by more than a factor of 3. The Level-B Analysis has a better sensitivity (not be worse than the final one by a factor of 2) and the results should be available within 10 hours from the acquisition of the data: for this reason this analysis could be performed at the end of an observation or next morning. The latency (in part...

  16. The small size telescope projects for the Cherenkov Telescope Array

    CERN Document Server

    ,

    2015-01-01

    The small size telescopes (SSTs), spread over an area of several square km, dominate the CTA sensitivity in the photon energy range from a few TeV to over 100 TeV, enabling for the detailed exploration of the very high energy gamma-ray sky. The proposed telescopes are innovative designs providing a wide field of view. Two of them, the ASTRI (Astrophysics con Specchi a Tecnologia Replicante Italiana) and the GCT (Gamma-ray Cherenkov Telescope) telescopes, are based on dual mirror Schwarzschild-Couder optics, with primary mirror diameters of 4 m. The third, SST-1M, is a Davies-Cotton design with a 4 m diameter mirror. Progress with the construction and testing of prototypes of these telescopes is presented. The SST cameras use silicon photomultipliers, with preamplifier and readout/trigger electronics designed to optimize the performance of these sensors for (atmospheric) Cherenkov light. The status of the camera developments is discussed. The SST sub-array will consist of about 70 telescopes at the CTA souther...

  17. Open-structure composite mirrors for the Cherenkov Telescope Array

    CERN Document Server

    Dyrda, Michal; Niemiec, Jacek; Stodulski, Marek

    2013-01-01

    The Cherenkov Telescope Array (CTA) Observatory for high-energy gamma-ray astronomy will comprise several tens of imaging atmospheric Cherenkov telescopes (IACTs) of different size with a total reflective area of about 10,000 m$^2$. Here we present a new technology for the production of IACT mirrors that has been developed in the Institute of Nuclear Physics PAS in Krakow, Poland. An open-structure composite mirror consists of a rigid flat sandwich support structure and cast-in-mould spherical epoxy resin layer. To this layer a thin glass sheet complete with optical coating is cold-slumped to provide the spherical reflective layer of the mirror. The main components of the sandwich support structure are two flat float glass panels inter spaced with V-shape aluminum spacers of equal length. The sandwich support structure is open, thus enabling good cooling and ventilation of the mirror. A special arrangement of the aluminum spacers also prohibits water being trapped inside. The open-structure technology thus re...

  18. Cherenkov and parametric (quasi-Cherenkov) radiation from relativistic charged particles moving in crystals formed by metallic wires

    CERN Document Server

    Baryshevsky, Vladimir

    2016-01-01

    Until recently, the interaction of electromagnetic waves with crystals built from parallel metallic wires (wire media) was analyzed in the approximation of isotropic scattering of the electromagnetic wave by a single wire. However, if the wires are thick (kR~1), electromagnetic wave scattering by a wire is anisotropic, i.e., the scattering amplitude depends on the scattering angle. In this work, we derive the equations that describe diffraction of electromagnetic waves and spontaneous emission of charged particles in wire media, and take into account the angular dependence of scattering amplitude. Numerical solutions of these equations show that the radiation intensity increases as the wire radius is increased and achieves its maximal value in the range kR~1. The case when the condition kR~1 is fulfilled in the THz frequency range is considered in detail. The calculations show that the instantaneous power of Cherenkov and parametric (quasi-Cherenkov) radiations from electron bunches in the crystal can be tens...

  19. Ultra-high resolution of radiocesium distribution detection based on Cherenkov light imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Seiichi, E-mail: s-yama@met.nagoya-u.ac.jp [Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine (Japan); Ogata, Yoshimune [Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine (Japan); Kawachi, Naoki; Suzui, Nobuo; Yin, Yong-Gen; Fujimaki, Shu [Radiotracer Imaging Group, Japan Atomic Energy Agency (Japan)

    2015-03-21

    After the nuclear disaster in Fukushima, radiocesium contamination became a serious scientific concern and research of its effects on plants increased. In such plant studies, high resolution images of radiocesium are required without contacting the subjects. Cherenkov light imaging of beta radionuclides has inherently high resolution and is promising for plant research. Since {sup 137}Cs and {sup 134}Cs emit beta particles, Cherenkov light imaging will be useful for the imaging of radiocesium distribution. Consequently, we developed and tested a Cherenkov light imaging system. We used a high sensitivity cooled charge coupled device (CCD) camera (Hamamatsu Photonics, ORCA2-ER) for imaging Cherenkov light from {sup 137}Cs. A bright lens (Xenon, F-number: 0.95, lens diameter: 25 mm) was mounted on the camera and placed in a black box. With a 100-μm {sup 137}Cs point source, we obtained 220-μm spatial resolution in the Cherenkov light image. With a 1-mm diameter, 320-kBq {sup 137}Cs point source, the source was distinguished within 2-s. We successfully obtained Cherenkov light images of a plant whose root was dipped in a {sup 137}Cs solution, radiocesium-containing samples as well as line and character phantom images with our imaging system. Cherenkov light imaging is promising for the high resolution imaging of radiocesium distribution without contacting the subject.

  20. Observations of the high-energy peaked BL Lac object H 1426+428 with the solar tower atmospheric Cherenkov effect experiment

    Science.gov (United States)

    Mueller, Carsten

    The Solar Tower Atmospheric Cherenkov Effect Experiment (STACEE) was an atmospheric Cherenkov telescope operational until June 2007, which detected cosmic gamma rays by means of the wavefront-sampling technique. Using 64 of the large heliostats available at the National Solar Thermal Test Facility (NSTTF) near Albuquerque, New Mexico, its total mirror area of 2378 m 2 allowed it to achieve energy thresholds between 150 and 200 GeV. Following a review of the field of gamma-ray astrophysics and Active Galactic Nuclei, this work provides a detailed description of the detector, along with an introduction to simulation and data analysis techniques. During the springs of 2003 and 2004, STACEE observed the High-Energy-Peaked BL Lac object H 1426+428, an established emitter of gamma rays in the TeV energy range. A full analysis of these data reveals that STACEE did not detect a statistically significant gamma-ray excess from H 1426+428 in either data set. With the help of detailed detector simulations, upper limits on the integrated gamma ray fluxes, phi int, at the 95% confidence level are obtained for both observing seasons: phi int(E > 163 GeV) 165 GeV) < 0.78·10-6 m-2 s-1 for 2003 and 2004, respectively. The derived upper limits are discussed in the context of the results obtained by other gamma-ray observatories.

  1. The Non-Imaging CHErenkov Array (NICHE): A TA/TALE extension to measure the flux and composition of Very-High Energy Cosmic Rays

    Science.gov (United States)

    Bergman, Douglas; Krizmanic, John; Sokolsky, Pierre

    2013-04-01

    Co-sited with TA/TALE, the Non-Imaging CHErenkov Array (NICHE) will measure the flux and nuclear composition of cosmic rays from below 10^16 eV to over 10^18 eV in its initial deployment. Furthermore, the low-energy reach can be lowered below the cosmic ray knee via counter redeployment or additional counters. NICHE uses easily deployable detectors to measure the amplitude and time-spread of the air-shower Cherenkov signal to achieve an event-by-event measurement of Xmax and energy, each with excellent resolution. NICHE will have sufficient area and angular acceptance to have significant overlap with the TA/TALE detectors to allow for energy cross-calibration. Simulated NICHE performance has shown that the array has the ability to distinguish between several different composition models as well as measure the end of Galactic cosmic ray spectrum. In this talk, the NICHE design, array performance, and status will be discussed as well as NICHE's ability to measure the cosmic ray nuclear composition as a function of energy.

  2. Operation, optimisation, and performance of the DELPHI RICH detectors

    CERN Document Server

    Albrecht, E; Augustinus, A; Baillon, Paul; Battaglia, Marco; Bloch, D; Boudinov, E; Brunet, J M; Carrié, P; Cavalli, P; Christophel, E; Davenport, M; Dracos, M; Eklund, L; Erzen, B; Fischer, P A; Fokitis, E; Fontanelli, F; Gracco, Valerio; Hallgren, A; Joram, C; Juillot, P; Kjaer, N J; Kluit, P M; Lenzen, G; Liko, D; Mahon, J R; Maltezos, S; Markou, A; Neufeld, N; Nielsen, B S; Petrolini, A; Podobnik, T; Polok, G; Sajot, G; Sannino, M; Schyns, E; Strub, R; Tegenfeldt, F; Thadome, J; Tristram, G; Ullaland, O; Vulpen, I V

    1999-01-01

    The Ring Imaging Cherenkov detectors of DELPHI represent a large-scale particle identification system which covers almost the full angular acceptance of DELPHI. The combination of liquid and gas radiators (C sub 4 F sub 1 sub 0 , C sub 5 F sub 1 sub 2 , and C sub 6 F sub 1 sub 4) provides particle identification over the whole secondary particle momentum spectrum at LEP I and LEP II. Continuing optimisation on the hardware as well as on the online and offline software level have resulted in a stable operation of the complete detector system for more than five years at full physics performance.

  3. A Novel UV Photon Detector with Resistive Electrodes

    CERN Document Server

    Bidault, J M; Francke, T; Galy, P; Peskov, Vladimir; Rodionov, I

    2006-01-01

    In this study we present first results from a new detector of UV photons: a thick gaseous electron multiplier (GEM) with resistive electrodes, combined with CsI or CsTe/CsI photocathodes. The hole type structure considerably suppresses the photon and ion feedback, whereas the resistive electrodes protect the detector and the readout electronics from damage by any eventual discharges. This device reaches higher gains than a previously developed photosensitive RPC and could be used not only for the imaging of UV sources, flames or Cherenkov light, for example, but also for the detection of X-rays and charged particles.

  4. A Pointing Solution for the Medium Size Telescopes for the Cherenkov Telescope Array

    CERN Document Server

    Tiziani, D; Oakes, L; Schwanke, U

    2016-01-01

    An important aspect of the calibration of the Cherenkov Telescope Array is the pointing, which enables an exact alignment of each telescope and therefore allows to transform a position in the sky to a point in the plane of the Cherenkov camera and vice versa. The favoured approach for the pointing calibration of the medium size telescopes (MST) is the installation of an optical CCD-camera in the dish of the telescope that captures the position of the Cherenkov camera and of the stars in the night sky simultaneously during data taking. The adaption of this approach is presented in this proceeding.

  5. The CPLEAR detector at CERN

    CERN Document Server

    Adler, R; Alhalel, T; Angelopoulos, Angelos; Apostolakis, Alcibiades J; Aslanides, Elie; Backenstoss, Gerhard; Bal, F; Bard, J P; Barraca, D; Bee, C P; Behnke, O; Benelli, A; Bennet, J; Bertin, V; Blanc, F; Bloch, P; Bonnet, M; Bula, C; Calzas, A; Carlson, P J; Carroll, M; Carvalho, J; Cawley, E; Charalambous, S; Chardalas, M; Chardin, G; Charra, P; Chertok, M B; Cody, A; Da Silva, J; Damianoglou, D; Daniel, R; Danielsson, M; Dechelette, Paul; Dedieu, M; Dedoussis, S; Dejardin, M; Derré, J; Dijksman, A; Dinkespiler, B; Dodgson, M; Dröge, M; Duclos, J; Dudragne, J; Durand, D; Ealet, A; Eckart, B; Eleftheriadis, C; Engster, Claude; Evangelou, I; Faravel, L; Fassnacht, P; Faure, J L; Felder, C; Ferreira-Marques, R; Fetscher, W; Fidecaro, Maria; Filipcic, A; Francis, D; Fry, J; Fuglesang, C; Gabathuler, Erwin; Gally, Y; Gamet, R; Garreta, D; Geiss, D; Geralis, R; Gerber, H J; Go, A; Gumplinger, P; Guyon, D; Guyot, C; Harrison, P; Harrison, P F; Haselden, A; Hayman, P J; Hazen, E S; Henry-Coüannier, F; Heyes, W G; Hollander, R W; Hubert, E; Jacobs, C; Jansson, K; Johner, H U; Jon-And, K; Karkour, N; Kérek, A; Kesseler, G; Kettle, P R; King, D; Klados, T; Kochowski, Claude; Kokkas, P; Kontek, K; Kreuger, R; Lawry, T; Lecouturier, T; Le Gac, R; Leimgruber, F; Linget, D; Liolios, A; Löfstedt, B; Louis, F; Machado, E; Maley, P; Mall, U; Mandic, I; Manthos, N; Marel, Gérard; Marin, C P; Martin, H; Michau, J C; Mikuz, M; Miller, J; Montanet, François; Nakada, Tatsuya; Nanni, F; Onofre, A; Pagels, B; Papadopoulos, I M; Pavlopoulos, P; Pelucchi, F; Petit, P; Philippoussis, K; Pinto da Cunha, J; Policarpo, Armando; Polivka, G; Postma, H; Rheme, C; Rickenbach, R; Roberts, B L; Rozaki, E; Ruf, T; Sacks, L; Sakelliou, L; Sanders, P; Santoni, C; Sarigiannis, K; Schäfer, M; Schaller, L A; Schietinger, T; Schopper, A; Schune, P; Soares, A; Steinacher, M; Tatsis, S; Tauscher, Ludwig; Thibault, C; Touchard, F; Touramanis, C; Triantis, F A; Tröster, D A; Tsamouranis, I; Tschopp, H; Tsilimigras, Panayiotis; Van Beveren, E; van Eijk, C W E; Van Koningsfeld, V; Vanuxem, J P; Varner, G S; Verweij, H; Vlachos, S; Warner, D; Watson, E; Weber, P; Wendler, H; Wigger, O; Witzig, C; Wolter, M; Yéche, C; Zavrtanik, D; Zimmerman, D

    1996-01-01

    The CPLEAR collaboration has constructed a detector at CERN for an extensive programme of CP-, T- and CPT-symmetry studies using ${\\rm K}^0$ and $\\bar{\\rm K}^0$ produced by the annihilation of $\\bar{\\rm p}$'s in a hydrogen gas target. The ${\\rm K}^0$ and $\\bar{\\rm K}^0$ are identified by their companion products of the annihilation ${\\rm K}^{\\pm} \\pi^{\\mp}$ which are tracked with multiwire proportional chambers, drift chambers and streamer tubes. Particle identification is carried out with a liquid Cherenkov detector for fast separation of pions and kaons and with scintillators which allow the measurement of time of flight and energy loss. Photons are measured with a lead/gas sampling electromagnetic calorimeter. The required antiproton annihilation modes are selected by fast online processors using the tracking chamber and particle identification information. All the detectors are mounted in a 0.44 T uniform field of an axial solenoid of diameter 2 m and length 3.6 m to form a magnetic spectrometer capable o...

  6. An Innovative Workspace for The Cherenkov Telescope Array

    CERN Document Server

    Costa, Alessandro; Becchini, Ugo; Massimino, Piero; Riggi, Simone; Sanchez, David; Vitello, Fabio

    2016-01-01

    The Cherenkov Telescope Array (CTA) is an initiative to build the next generation, ground-based gamma-ray observatories. We present a prototype workspace developed at INAF that aims at providing innovative solutions for the CTA community. The workspace leverages open source technologies providing web access to a set of tools widely used by the CTA community. Two different user interaction models, connected to an authentication and authorization infrastructure, have been implemented in this workspace. The first one is a workflow management system accessed via a science gateway (based on the Liferay platform) and the second one is an interactive virtual desktop environment. The integrated workflow system allows to run applications used in astronomy and physics researches into distributed computing infrastructures (ranging from clusters to grids and clouds). The interactive desktop environment allows to use many software packages without any installation on local desktops exploiting their native graphical user i...

  7. Coherent Cherenkov radiation as an intense THz source

    Science.gov (United States)

    Bleko, V.; Karataev, P.; Konkov, A.; Kruchinin, K.; Naumenko, G.; Potylitsyn, A.; Vaughan, T.

    2016-07-01

    Diffraction and Cherenkov radiation of relativistic electrons from a dielectric target has been proposed as mechanism for production of intense terahertz (THz) radiation. The use of an extremely short high-energy electron beam of a 4th generation light source (X-ray free electron laser) appears to be very promising. A moderate power from the electron beam can be extracted and converted into THz radiation with nearly zero absorption losses. The initial experiment on THz observation will be performed at CLARA/VELA FEL test facility in the UK to demonstrate the principle to a wider community and to develop the radiator prototype. In this paper, we present our theoretical predictions (based on the approach of polarization currents), which provides the basis for interpreting the future experimental measurements. We will also present our hardware design and discuss a plan of the future experiment.

  8. Vacuum Cherenkov radiation and bremsstrahlung from disformal couplings

    Science.gov (United States)

    van de Bruck, Carsten; Burrage, Clare; Morrice, Jack

    2016-08-01

    The simplest way to modify gravity is to extend the gravitational sector to include an additional scalar degree of freedom. The most general metric that can be built in such a theory includes disformal terms, so that standard model fields move on a metric which is the sum of the space time metric and a tensor constructed from first derivatives of the scalar. In such a theory gravitational waves and photons can propagate at different speeds, and these can in turn be different from the maximum speed limit for matter particles. In this work we show that disformal couplings can cause charged particles to emit Cherenkov radiation and bremsstrahlung apparently in vacuum, depending on the background evolution of the scalar field. We discuss the implications of this for observations of cosmic rays, and the constraints that arise for models of dark energy with disformal couplings.

  9. Data model issues in the Cherenkov Telescope Array project

    CERN Document Server

    Contreras, J L; Bernlöhr, K; Boisson, C; Bregeon, J; Bulgarelli, A; de Cesare, G; Reyes, R de los; Fioretti, V; Kosack, K; Lavalley, C; Lyard, E; Marx, R; Rico, J; Sanguillot, M; Servillat, M; Walter, R; Ward, J E

    2015-01-01

    The planned Cherenkov Telescope Array (CTA), a future ground-based Very-High-Energy (VHE) gamma-ray observatory, will be the largest project of its kind. It aims to provide an order of magnitude increase in sensitivity compared to currently operating VHE experiments and open access to guest observers. These features, together with the thirty years lifetime planned for the installation, impose severe constraints on the data model currently being developed for the project. In this contribution we analyze the challenges faced by the CTA data model development and present the requirements imposed to face them. While the full data model is still not completed we show the organization of the work, status of the design, and an overview of the prototyping efforts carried out so far. We also show examples of specific aspects of the data model currently under development.

  10. Building Medium Size Telescope Structures for the Cherenkov Telescope Array

    CERN Document Server

    Schulz, A; Oakes, L; Schlenstedt, S; Schwanke, U

    2016-01-01

    The Cherenkov Telescope Array (CTA) is the future instrument in ground-based gamma-ray astronomy in the energy range from 20 GeV to 300 TeV. Its sensitivity will surpass that of current generation experiments by a factor $\\sim$10, facilitated by telescopes of three sizes. The performance in the core energy regime will be dominated by Medium Size Telescopes (MST) with a reflector of 12 m diameter. A full-size mechanical prototype of the telescope structure has been constructed in Berlin. The performance of the prototype is being evaluated and optimisations, among others, facilitating the assembly procedure and mass production possibilities are being implemented. We present the current status of the developments from prototyping towards pre-production telescopes, which will be deployed at the final site.

  11. Charged Kaon Mass Measurement using the Cherenkov Effect

    CERN Document Server

    Graf, N; Abrams, R J; Akgun, U; Aydin, G; Baker, W; Barnes, P D; Bergfeld, T; Beverly, L; Bujak, A; Carey, D; Dukes, C; Duru, F; Feldman, G J; Godley, A; Gülmez, E; Günaydın, Y O; Gustafson, H R; Gutay, L; Hartouni, E; Hanlet, P; Hansen, S; Heffner, M; Johnstone, C; Kaplan, D; Kamaev, O; Kilmer, J; Klay, J; Kostin, M; Lange, D; Ling, J; Longo, M J; Lu, L C; Materniak, C; Messier, M D; Meyer, H; Miller, D E; Mishra, S R; Nelson, K; Nigmanov, T; Norman, A; Onel, Y; Paley, J M; Park, H K; Penzo, A; Peterson, R J; Raja, R; Rajaram, D; Ratnikov, D; Rosenfeld, C; Rubin, H; Seun, S; Solomey, N; Soltz, R; Swallow, E; Schmitt, R; Subbarao, P; Torun, Y; Tope, T E; Wilson, K; Wright, D; Wu, K

    2009-01-01

    The two most recent and precise measurements of the charged kaon mass use X-rays from kaonic atoms and report uncertainties of 14 ppm and 22 ppm yet differ from each other by 122 ppm. We describe the possibility of an independent mass measurement using the measurement of Cherenkov light from a narrow-band beam of kaons, pions, and protons. This technique was demonstrated using data taken opportunistically by the Main Injector Particle Production experiment at Fermi National Accelerator Laboratory which recorded beams of protons, kaons, and pions ranging in momentum from +37 GeV/c to +63 GeV/c. The measured value is 491.3 +/- 1.7 MeV/c^2, which is within 1.4 sigma of the world average. An improvement of two orders of magnitude in precision would make this technique useful for resolving the ambiguity in the X-ray data and may be achievable in a dedicated experiment.

  12. Data compression for the First G-APD Cherenkov Telescope

    CERN Document Server

    Ahnen, M L; Bergmann, M; Biland, A; Bretz, T; Buß, J; Dorner, D; Einecke, S; Freiwald, J; Hempfling, C; Hildebrand, D; Hughes, G; Lustermann, W; Lyard, E; Mannheim, K; Meier, K; Mueller, S; Neise, D; Neronov, A; Overkemping, A -K; Paravac, A; Pauss, F; Rhode, W; Steinbring, T; Temme, F; Thaele, J; Toscano, S; Vogler, P; Walter, R; Wilbert, A

    2015-01-01

    The First Geiger-mode Avalanche photodiode (G-APD) Cherenkov Telescope (FACT) has been operating on the Canary island of La Palma since October 2011. Operations were automated so that the system can be operated remotely. Manual interaction is required only when the observation schedule is modified due to weather conditions or in case of unexpected events such as a mechanical failure. Automatic operations enabled high data taking efficiency, which resulted in up to two terabytes of FITS files being recorded nightly and transferred from La Palma to the FACT archive at ISDC in Switzerland. Since long term storage of hundreds of terabytes of observations data is costly, data compression is mandatory. This paper discusses the design choices that were made to increase the compression ratio and speed of writing of the data with respect to existing compression algorithms. Following a more detailed motivation, the FACT compression algorithm along with the associated I/O layer is discussed. Eventually, the performances...

  13. Early attempts at atmospheric simulations for the Cherenkov Telescope Array

    CERN Document Server

    Rulten, Cameron B

    2014-01-01

    The Cherenkov Telescope Array (CTA) will be the world's first observatory for detecting gamma-rays from astrophysical phenomena and is now in its prototyping phase with construction expected to begin in 2015/16. In this work we present the results from early attempts at detailed simulation studies performed to assess the need for atmospheric monitoring. This will include discussion of some lidar analysis methods with a view to determining a range resolved atmospheric transmission profile. We find that under increased aerosol density levels, simulated gamma-ray astronomy data is systematically shifted leading to softer spectra. With lidar data we show that it is possible to fit atmospheric transmission models needed for generating lookup tables, which are used to infer the energy of a gamma-ray event, thus making it possible to correct affected data that would otherwise be considered unusable.

  14. Evidence for Observation of Virtual Radio Cherenkov Fields

    CERN Document Server

    Bean, Alice; Snow, James

    2010-01-01

    We present evidence for observation of virtual electromagnetic fields in the radio domain from experiment T926 at the Fermilab Meson Test Beam Facility. Relativistic protons with 120 GeV energy traversed a sealed electromagnetic cavity and were observed in the radio regime of 200MHz-GHz. Closely related to ordinary Cherenkov radiation, which we also measured, the virtual fields require no acceleration for their existence. The experiment is also the first observation of fields from hadronic showers, an independent and new confirmation of coherent radio emission from ultra-relativistic particles. Conditions of very low signal to noise were overcome by a novel and unbiased filtering strategy that exploits exhaustive studies of correlations in the noise backgrounds. Linear scaling of the signal region with the number of beam particles provides evidence of coherence. Extrapolation to measurement of the field of a single relativistic proton charge is consistent within errors. Our study also illustrates new data pro...

  15. FACT: Towards Robotic Operation of an Imaging Air Cherenkov Telescope

    CERN Document Server

    Biland, A; Backes, M; Boccone, V; Braun, I; Bretz, T; Buss, J; Cadoux, F; Commichau, V; Djambazov, L; Dorner, D; Einecke, S; Eisenacher, D; Gendotti, A; Grimm, O; von Gunten, H; Haller, C; Hildebrand, D; Horisberger, U; Huber, B; Kim, K -S; Knoetig, M L; Koehne, J -H; Kraehenbuehl, T; Krumm, B; Lee, M; Lorenz, E; Lustermann, W; Lyard, E; Mannheim, K; Meharga, M; Meier, K; Montaruli, T; Neise, D; Nessi-Tedaldi, F; Overkemping, A -K; Paravac, A; Pauss, F; Renker, D; Rhode, W; Ribordy, M; Roeser, U; Stucki, J -P; Schneider, J; Steinbring, T; Temme, F; Thaele, J; Tobler, S; Viertel, G; Vogler, P; Walter, R; Warda, K; Weitzel, Q; Zaenglein, M

    2013-01-01

    The First G-APD Cherenkov Telescope (FACT) became operational at La Palma in October 2011. Since summer 2012, due to very smooth and stable operation, it is the first telescope of its kind that is routinely operated from remote, without the need for a data-taking crew on site. In addition, many standard tasks of operation are executed automatically without the need for manual interaction. Based on the experience gained so far, some alterations to improve the safety of the system are under development to allow robotic operation in the future. We present the setup and precautions used to implement remote operations and the experience gained so far, as well as the work towards robotic operation.

  16. Vacuum Cherenkov radiation and bremsstrahlung from disformal couplings

    CERN Document Server

    van de Bruck, Carsten; Morrice, Jack

    2016-01-01

    The simplest way to modify gravity is to extend the gravitational sector to include an additional scalar degree of freedom. The most general metric that can be built in such a theory includes disformal terms, so that standard model fields move on a metric which is the sum of the space time metric and a tensor constructed from first derivatives of the scalar. In such a theory gravitational waves and photons can propagate at different speeds, and these can in turn be different from the maximum speed limit for matter particles. In this work we show that disformal couplings can cause charged particles to emit Cherenkov radiation and bremsstrahlung apparently in vacuum, depending on the background evolution of the scalar field. We discuss the implications of this for observations of cosmic rays, and the constraints that arise for models of dark energy with disformal couplings.

  17. The SST-1M camera for the Cherenkov Telescope Array

    CERN Document Server

    Schioppa, E J; Christov, A.; della Volpe, D.; Favre, Y.; Heller, M.; Montaruli, T.; Porcelli, A.; Rameez, M.; Pujadas, I. Troyano; Bilnik, W.; Blocki, J.; Bogacz, L.; Bulik, T.; Curylo, M.; Dyrda, M.; Frankowski, A.; Grudniki, L.; Grudzinska, M.; Idzkowski, B.; Jamrozy, M.; Janiak, M.; Kasperek, J.; Lalik, K.; Lyard, E.; Mach, E.; Mandat, D.; Marszalek, A.; Michaowski, J.; Moderski, R.; Neronov, A.; Niemiec, J.; Ostrowski, M.; Pasko, P.; Pech, M.; Prandini, E.; Rajda, P.; Schovanek, P.; Seweryn, K.; Skowron, K.; Sliusar, V.; Sowinski, M.; Stawarz, L.; Stodulska, M.; Stodulski, M.; Toscano, S.; Walter, R.; Wiecek, M.; Zagdanski, A.; Zietara, K.; Zychowski, P.

    2015-01-01

    The prototype camera of the single-mirror Small Size Telescopes (SST-1M) proposed for the Cherenkov Telescope Array (CTA) project has been designed to be very compact and to deliver high performance over thirty years of operation. The camera is composed of an hexagonal photo-detection plane made of custom designed large area hexagonal silicon photomultipliers and a high throughput, highly configurable, fully digital readout and trigger system (DigiCam). The camera will be installed on the telescope structure at the H. Niewodnicza{\\'n}ski institute of Nuclear Physics in Krakow in fall 2015. In this contribution, we review the steps that led to the development of the innovative photo-detection plane and readout electronics, and we describe the test and calibration strategy adopted.

  18. Smart Analogue Sampler for the Optical Module of a Cherenkov Neutrino Detector

    CERN Document Server

    Caponetto, L; Russo, G V; Randazzo, N

    2009-01-01

    A transient waveform sampler/recorder IC has been developed and realized in AMS C35B4 technology. This chip has been designed to fit the needs of a proposal for a front-end architecture for the readout of the anode signal of the photomultipliers in an underwater neutrino telescope. The design is based around a 3 channels x 32 cells switched capacitor array unit sampling its voltage inputs at 200MHz external clock rate and transferring the stored analogue voltage samples to its single analogue output at 1/10th of the sampling rate. This unit is replicated inside the ASIC providing 4 independent analogue sampling queues for signal transients up to 32 x 5 ns and a fifth unit storing transients up to 128 x 5 ns. A micro-pipelined unit, based on Muller C-gates, controls the 5 independent samplers. This paper briefly summarizes the complete front-end architecture and discusses in more detail the internal structure of the ASIC and its first functional tests.

  19. Research on mutual influence of Cherenkov-type probes within the ISTTOK tokamak chamber

    Energy Technology Data Exchange (ETDEWEB)

    Jakubowski, L., E-mail: lech.jakubowski@ncbj.gov.pl [National Centre for Nuclear Research (NCBJ), 05-400 Otwock (Poland); Plyusnin, V.V. [Association Euratom/IST, Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Av. Rovisco Pais, 1049-001 Lisboa (Portugal); Malinowski, K.; Sadowski, M.J.; Zebrowski, J.; Rabinski, M. [National Centre for Nuclear Research (NCBJ), 05-400 Otwock (Poland); Fernandes, H.; Silva, C.; Figueiredo, H. [Association Euratom/IST, Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Av. Rovisco Pais, 1049-001 Lisboa (Portugal); Jakubowski, M.J. [National Centre for Nuclear Research (NCBJ), 05-400 Otwock (Poland)

    2014-12-11

    The paper describes an influence of a Cherenkov-type probe, which is used for measurements of fast electron streams inside the ISTTOK chamber, on other probes and behaviour of a plasma ring. The reported study shows that such a probe situated near the plasma column has a strong influence on signals from another Cherenkov probe, and can cause a considerable reduction of electron-induced signals. This effect does not depend on positions of the probes in relation to the limiter. Measurements of hard X-ray (HXR) emission show that the deeply immersed Cherenkov probe can also influence on the limiter . Under specific experimental conditions such a Cherenkov probe can play the role of a new limiter and change the plasma configuration.

  20. Ionospheric propagation effects for UHE neutrino detection with the lunar Cherenkov technique

    CERN Document Server

    McFadden, Rebecca; Bray, Justin

    2013-01-01

    Lunar Cherenkov experiments aim to detect nanosecond pulses of Cherenkov emission produced during UHE cosmic ray or neutrino interactions in the lunar regolith. Pulses from these interactions are dispersed, and therefore reduced in amplitude, during propagation through the Earth's ionosphere. Pulse dispersion must therefore be corrected to maximise the received signal to noise ratio and subsequent chances of detection. The pulse dispersion characteristic may also provide a powerful signature to determine the lunar origin of a pulse and discriminate against pulses of terrestrial radio frequency interference (RFI). This characteristic is parameterised by the instantaneous Total Electron Content (TEC) of the ionosphere and therefore an accurate knowledge of the ionospheric TEC provides an experimental advantage for the detection and identification of lunar Cherenkov pulses. We present a new method to calibrate the dispersive effect of the ionosphere on lunar Cherenkov pulses using lunar Faraday rotation measurem...

  1. Extension of Cherenkov Light LDF Parametrization for Tunka and Yakutsk EAS Arrays

    Indian Academy of Sciences (India)

    A. A. Al-Rubaiee

    2014-12-01

    The Cherenkov light Lateral Distribution Function (LDF) from particles initiated Extensive Air Showers (EAS) with ultrahigh energies ( > 1016 eV) was simulated using CORSIKA program for configuration of Tunka and Yakutsk EAS arrays for different primary particles (p, Fe and O2) and different zenith angles. By depending on the Breit–Wigner function, a parametrization of the Cherenkov light LDF was reconstructed on the basis of this simulation as a function of the primary energy. The comparison of the approximated Cherenkov light LDF with that measured on Tunka and Yakutsk EAS arrays gives the possibility of identification of energy spectrum and mass composition of particles initiating EAS about the knee region of the cosmic ray spectrum. The extrapolation of approximated Cherenkov light LDF for energies 20, 30 and 50 PeV was obtained for different primary particles and different zenith angles.

  2. Very high energy emission of Crab-like pulsars driven by the Cherenkov drift radiation

    CERN Document Server

    Osmanov, Z

    2015-01-01

    In this paper we study the generation of very high energy (VHE) emission in Crab-like pulsars driven by means of the feedback of Cherenkov drift waves on distribution of magnetospheric electrons. We have found that the unstable Cherenkov drift modes lead to the quasi-linear diffusion (QLD), keeping the pitch angles from vanishing, which in turn, maintains the synchrotron mechanism. Considering the Crab-like pulsars it has been shown that the growth rate of the Cherenkov drift instability (ChDI) is quite high, indicating high efficiency of the process. Analyzing the mechanism for the typical parameters we have found that the Cherenkov drift emission from the extreme UV to hard $X$-rays is strongly correlated with the VHE synchrotron emission in the GeV band.

  3. Infrared detectors

    CERN Document Server

    Rogalski, Antonio

    2010-01-01

    This second edition is fully revised and reorganized, with new chapters concerning third generation and quantum dot detectors, THz detectors, cantilever and antenna coupled detectors, and information on radiometry and IR optics materials. Part IV concerning focal plane arrays is significantly expanded. This book, resembling an encyclopedia of IR detectors, is well illustrated and contains many original references … a really comprehensive book.-F. Sizov, Institute of Semiconductor Physics, National Academy of Sciences, Kiev, Ukraine

  4. Intense Cherenkov-type terahertz electromagnetic radiation from ultrafast laser-plasma interaction

    Institute of Scientific and Technical Information of China (English)

    Hu Qiang-Lin; Liu Shi-Bing; Li Wei

    2008-01-01

    A Cherenkov-type terahertz electromagnetic radiation is revealed, which results efficiently from the collective effects in the time-domain of ultrafast pulsed electron current produced by ultrafast intense laser-plasma interaction.The emitted pulse waveform and spectrum, and the dependence of laser pulse parameters on the structure of the radiation field are investigated numerically. The condition of THz radiation generation in this regime and Cherenkov geometry of the radiation field are studied analytically.

  5. Status of non-destructive bunch length measurement based on coherent Cherenkov radiation

    CERN Document Server

    Zhang, Jianbing; Yu, Tiemin; Deng, Haixiao; Shkitov, Dmitry; Shevelev, Mikhail; Naumenko, Gennady; Potylitsyn, Alexander

    2013-01-01

    As a novel non-destructive bunch length diagnostic of the electron beam, an experimental observation of the coherent Cherenkov radiation generated from a dielectric caesium iodide crystal with large spectral dispersion was proposed for the 30MeV femtosecond linear accelerator at Shanghai Institute of Applied Physics (SINAP). In this paper, the theoretical design, the experimental setup, the terahertz optics, the first angular distribution observations of the coherent Cherenkov radiation, and the future plans are presented.

  6. In situ, high sensitivity, measurement of sup 9 sup 0 strontium in ground water using Cherenkov light

    CERN Document Server

    Bowyer, T W; Hossbach, T W; Hansen, R; Wilcox, W A

    2000-01-01

    The measurement of sup 9 sup 0 Sr in soils and ground water is important for characterization and remediation of radioactively contaminated sites. Measuring the sup 9 sup 0 Sr content to a few pCi/g of soil has been accomplished based on a design of scintillating fibers in a multilayered configuration measuring the high-energy beta emitted from sup 9 sup 0 Y decay (when in secular equilibrium with sup 9 sup 0 Sr), but has not been applied to water because the technique is sensitive to only the first few mm of soil. The volume of the source to which the detector is sensitive limits the theoretical sensitivity of such a detector, unless chemical preprocessing to strip the sup 9 sup 0 Sr from the water is performed. sup 9 sup 0 Sr activity in water can be quantified by detecting the high-energy beta particle by the Cherenkov light it produces when the high-energy beta from sup 9 sup 0 Y passes through the medium. We have used this phenomenon to sensitively measure sup 9 sup 0 Sr ( sup 9 sup 0 Y) from a volume of...

  7. Icecube, the World's Largest Dark Matter Detector

    CERN Document Server

    Landsman, H

    2006-01-01

    IceCube is a kilometer scale high-energy neutrino observatory, currently under construction at the South Pole. It is a photo-detector, using the deep Antarctic ice as detection medium for the Cherenkov photons induced by relativistic charged particles. These charged particles may be atmospheric muons or reaction products from neutrino interactions in the vicinity of the instrumented volume. The experiment searches for neutrinos originating in astrophysical sources, and can also detect neutrinos from WIMP interaction in the Sun or Earth. In the last two austral summers, 9 in-ice strings and 16 surface IceTop stations (out of up to 80 planned) were successfully deployed, and the detector has been taking data ever since. In this proceedings, IceCube design, present status, performance and dark matter detection sensitivities will be discussed.

  8. CERN-built prototype RICH detector back from the USA

    CERN Multimedia

    Maximilien Brice

    2002-01-01

    In summer 1999, a ring-imaging Cherenkov detector (RICH) developed, constructed and tested at CERN was dismantled and sent to the Brookhaven National Laboratory (BNL) where it was used to extend the particle identification range of the STAR detector at the Relativistic Heavy Ion Collider (RHIC). The RICH was a prototype of part of the ALICE-HMPID detector. Here we see members of the STAR-RICH team from ALICE-HMPID group with the detector, still in its shipping crates, back from BNL. L. to r.: A.Braem, E. Schyns, D. Fraissard, C. David, A. Di Mauro, J. van Beelen, G. Paic, Y. Lesenechal, F. Piuz, P. Martinengo, D. Di Bari, G. De Cataldo, Y. Andres, M. Davenport, V. Barozier, E. Nappi, T. D. Williams.

  9. Isotope separation with the RICH detector of the AMS Experiment

    CERN Document Server

    Arruda, Luísa; Borges, João; Carmo, Fernando; Gonçalves, Patrícia; Pereira, Rui; Pimenta, Mário

    2007-01-01

    The Alpha Magnetic Spectrometer (AMS), to be installed on the International Space Station (ISS) in 2008, is a cosmic ray detector with several subsystems, one of which is a proximity focusing Ring Imaging Cherenkov (RICH) detector. This detector will be equipped with a dual radiator (aerogel+NaF), a lateral conical mirror and a detection plane made of 680 photomultipliers and light guides, enabling precise measurements of particle electric charge and velocity. Combining velocity measurements with data on particle rigidity from the AMS Tracker it is possible to obtain a measurement for particle mass, allowing the separation of isotopes. A Monte Carlo simulation of the RICH detector, based on realistic properties measured at ion beam tests, was performed to evaluate isotope separation capabilities. Results for three elements -- H (Z=1), He (Z=2) and Be (Z=4) -- are presented.

  10. Monitoring of absolute mirror alignment at COMPASS RICH-1 detector

    Energy Technology Data Exchange (ETDEWEB)

    Alexeev, M. [INFN, Sezione di Torino and University of East Piemonte, Alessandria (Italy); INFN, Sezione di Trieste and University of Bari, Bari (Italy); Birsa, R. [INFN, Sezione di Trieste, Trieste (Italy); Bradamante, F.; Bressan, A. [INFN, Sezione di Trieste and University of Trieste, Trieste (Italy); Chiosso, M. [INFN, Sezione di Torino and University of Torino, Torino (Italy); Ciliberti, P. [INFN, Sezione di Trieste and University of Trieste, Trieste (Italy); Dalla Torre, S. [INFN, Sezione di Trieste, Trieste (Italy); Denisov, O. [INFN, Sezione di Torino, Torino (Italy); Duic, V. [INFN, Sezione di Trieste and University of Trieste, Trieste (Italy); Ferrero, A. [INFN, Sezione di Torino and University of Torino, Torino (Italy); Finger, M.; Finger, M. [Charles University, Prague (Czech Republic); JINR, Dubna (Russian Federation); Gayde, J.Ch. [CERN, European Organization for Nuclear Research, Geneva (Switzerland); Giorgi, M. [INFN, Sezione di Trieste and University of Trieste, Trieste (Italy); Gobbo, B.; Levorato, S. [INFN, Sezione di Trieste, Trieste (Italy); Maggiora, A. [INFN, Sezione di Torino, Torino (Italy); Martin, A. [INFN, Sezione di Trieste and University of Trieste, Trieste (Italy); Menon, G. [INFN, Sezione di Trieste, Trieste (Italy); Panzieri, D. [INFN, Sezione di Torino and University of East Piemonte, Alessandria (Italy); and others

    2014-12-01

    The gaseous COMPASS RICH-1 detector uses two spherical mirror surfaces, segmented into 116 individual mirrors, to focus the Cherenkov photons onto the detector plane. Any mirror misalignment directly affects the detector resolution. The on-line Continuous Line Alignment and Monitoring (CLAM) photogrammetry-based method has been implemented to measure the alignment of individual mirrors which can be characterized by the center of curvature. The mirror wall reflects a regular grid of retroreflective strips placed inside the detector vessel. Then, the position of each mirror is determined from the image of the grid reflection. The images are collected by four cameras. Any small mirror misalignment results in changes of the grid lines’ positions in the image. The accuracy limits of the CLAM method were checked by laser interferometry and are below 0.1 mrad.

  11. CALDER: cryogenic light detector for rare events search

    CERN Document Server

    Pagnanini, L; Bellini, F; Calvo, M; Cardani, L; Casali, N; Castellano, M G; Colantoni, I; Coppolecchia, A; Cosmelli, C; Cruciani, A; De Bernardis, P; Di Domizio, S; D'Addabbo, A; Martinez, M; Masi, S; Tomei, C; Vignati, M

    2015-01-01

    The CALDER project aims at developing cryogenic light detectors with high sensitivity to UV and visible light, to be used for particle tagging in massive bolometers. Indeed the sensitivity of CUORE can be increased by a factor of 3, thanks to the reduction of the $\\alpha$-background, obtained by detecting the Cherenkov light (100 eV) emitted by $\\beta/\\gamma$ events. Currently used light detectors have not the features required to address this task, so we decided to develop a new light detector using Kinetic Inductance Detector as a sensor. This approach is very challenging and requires an intensive R$\\&$D to be satisfied. The first results of this activity are shown in the following.

  12. R&D studies of a RICH detector using pressurized C$_{4}$F$_{8}$O radiator gas and a CsI-based gaseous photon detector

    CERN Document Server

    Agócs, A.G; Barnaföldi, G.G; Bellwied, R; Bencédi, G; Bencze, G; Berényi, D; Boldizsár, L; Chattopadhyay, S; Chinellato, D.D; Cindolo, F; Das-Bose, L; Das, D; Das, K; De Cataldo, G; Di Bari, D; Di Mauro, A; Futó, E; Garcia, E; Hamar, G; Harton, A; Jimenez, R.T; Kim, D.W; Kim, J.S; Knospe, A; Kovacs, L; Lévai, P; Markert, C; Martinengo, P; Molnar, L; Nappi, E; Olah, L; Paic, G; Pastore, C; Patino, M.E; Peskov, V; Pinsky, L; Piuz, F; Pochybova, S; Sgura, I; Sinha, T; Song, J; Timmins, A; Van Beelen, J.B; Varga, D; Volpe, G; Weber, M; Xaplanteris, L; Yi, J; Yoo, I.-K

    2013-01-01

    We report on studies of layout and performance of a new Ring Imaging Cherenkov detector using for the fi rst time pressurized C 4 F 8 O radiator gas and a photon detector consisting of a MWPC equipped with a CsI photocathode. In particular, we present here the results of beam tests of a MWPC having an adjustable anode – cathode gap, aiming at the optimization of single photoelectron detection and Cherenkov angle resolution. This system was proposed as a Very High Momentum Particle Identi fi cation (VHMPID) upgrade for the ALICE experiment at LHC to provide charged hadron track-by-track identi fi cation in the momentum range 5 – 25 GeV/c.

  13. The software architecture to control the Cherenkov Telescope Array

    Science.gov (United States)

    Oya, I.; Füßling, M.; Antonino, P. O.; Conforti, V.; Hagge, L.; Melkumyan, D.; Morgenstern, A.; Tosti, G.; Schwanke, U.; Schwarz, J.; Wegner, P.; Colomé, J.; Lyard, E.

    2016-07-01

    The Cherenkov Telescope Array (CTA) project is an initiative to build two large arrays of Cherenkov gamma- ray telescopes. CTA will be deployed as two installations, one in the northern and the other in the southern hemisphere, containing dozens of telescopes of different sizes. CTA is a big step forward in the field of ground- based gamma-ray astronomy, not only because of the expected scientific return, but also due to the order-of- magnitude larger scale of the instrument to be controlled. The performance requirements associated with such a large and distributed astronomical installation require a thoughtful analysis to determine the best software solutions. The array control and data acquisition (ACTL) work-package within the CTA initiative will deliver the software to control and acquire the data from the CTA instrumentation. In this contribution we present the current status of the formal ACTL system decomposition into software building blocks and the relationships among them. The system is modelled via the Systems Modelling Language (SysML) formalism. To cope with the complexity of the system, this architecture model is sub-divided into different perspectives. The relationships with the stakeholders and external systems are used to create the first perspective, the context of the ACTL software system. Use cases are employed to describe the interaction of those external elements with the ACTL system and are traced to a hierarchy of functionalities (abstract system functions) describing the internal structure of the ACTL system. These functions are then traced to fully specified logical elements (software components), the deployment of which as technical elements, is also described. This modelling approach allows us to decompose the ACTL software in elements to be created and the ow of information within the system, providing us with a clear way to identify sub-system interdependencies. This architectural approach allows us to build the ACTL system model and

  14. New electronics for the Cherenkov Telescope Array (NECTAr)

    Energy Technology Data Exchange (ETDEWEB)

    Naumann, C.L., E-mail: christopher.naumann@lpnhe.in2p3.fr [LPNHE, IN2P3/CNRS Universite Paris VI and Universite Paris VII and IN2P3/CNRS, Paris (France); Delagnes, E. [IRFU, CEA/DSM, Saclay, Gif-sur-Yvette (France); Bolmont, J.; Corona, P. [LPNHE, IN2P3/CNRS Universite Paris VI and Universite Paris VII and IN2P3/CNRS, Paris (France); Dzahini, D. [LPSC, Universite Joseph Fourier, INPG and IN2P3/CNRS, Grenoble (France); Feinstein, F. [LUPM, Universite Montpellier II and IN2P3/CNRS, Montpellier (France); Gascon, D. [ICC-UB, Universitat Barcelona (Spain); Glicenstein, J.-F.; Guilloux, F. [IRFU, CEA/DSM, Saclay, Gif-sur-Yvette (France); Nayman, P. [LPNHE, IN2P3/CNRS Universite Paris VI and Universite Paris VII and IN2P3/CNRS, Paris (France); Rarbi, F. [LPSC, Universite Joseph Fourier, INPG and IN2P3/CNRS, Grenoble (France); Sanuy, A. [ICC-UB, Universitat Barcelona (Spain); Tavernet, J.-P.; Toussenel, F.; Vincent, P. [LPNHE, IN2P3/CNRS Universite Paris VI and Universite Paris VII and IN2P3/CNRS, Paris (France); Vorobiov, S. [LUPM, Universite Montpellier II and IN2P3/CNRS, Montpellier (France); DESY Zeuthen, Platanenallee 6, 15738 Zeuthen (Germany)

    2012-12-11

    The international CTA consortium has recently entered into its preparatory phase towards the construction of the next-generation Cherenkov Telescope Array CTA. This experiment will be a successor, and based on the return of experience from the three major current-generation arrays H.E.S.S., MAGIC and VERITAS, and aims to significantly improve upon the sensitivity as well as the energy range of its highly successful predecessors. Construction is planned to begin by 2013, and when finished, CTA will be able to explore the highest-energy gamma ray sky in unprecedented detail. To achieve this increase in sensitivity and energy range, CTA will employ the order of 100 telescopes of three different sizes on two sites, with around 1000-4000 channels per camera, depending on the telescope size. To equip and reliably operate the order of 100000 channels of photodetectors (compared to 6000 of the H.E.S.S. array), a new kind of flexible and powerful yet inexpensive front-end hardware will be required. One possible solution is pursued by the NECTAr (New Electronics for the Cherenkov Telescope Array) project. Its main feature is the integration of as much as possible of the front-end electronics (amplifiers, fast analogue samplers, memory and ADCs) into a single ASIC, which will allow very fast readout performances while significantly reducing the cost and the power consumption per channel. Also included is a low-cost FPGA for digital treatment and online data processing, as well as an Ethernet connection. Other priorities of NECTAr are the modularity of the system, a high degree of flexibility in the trigger system as well as the possibility of flexible readout modes to optimise the signal-to-noise ratio while at the same time allowing a significant reduction of data rates, both of which could improve the sensitivity of CTA compared to current detection systems. This paper gives an overview over the development work for the Nectar system, with particular focus on its main

  15. R and D status of a large-aperture hybrid avalanche photo-detector

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Toshinori, E-mail: toshi@hep.phys.s.u-tokyo.ac.j [University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Aihara, Hiroaki; Iwasaki, Masako; Fujimori, Hiroki; Kasimura, Keizo; Mineo, Sogo; Uchida, Tomohisa [University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Tanaka, Manobu [Institute for Particle and Nuclear Studies, High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Kawai, Yoshihiko; Kyushima, Hiroyuki; Suyama, Motohiro [Electron Tube Division, Hamamatsu Photonics K.K., 314-5 Shimokanzo, Iwata City, Shizuoka 438-0193 (Japan); Shiozawa, Masato [Kamioka Observatory, Institute for Cosmic Ray Research ICRR, University of Tokyo, Higashi-Mozumi, Kamioka-cho, Hida City, Gifu 506-1205 (Japan)

    2010-11-01

    This paper reports on the R and D status of a large-aperture Hybrid Avalanche Photo-Detector (HAPD). We have developed a 13-inch aperture HAPD and its readout system. The HAPD is a photo-detector expected to replace the photomultiplier tube (PMT) in next-generation imaging water Cherenkov detectors such as Hyper Kamiokande. We will present the recent progress made in readout system development. The readout system involves a fast sampling device. The sampling depth (number of cells) has been extended to 256 from 64 in order to measure longer waveform length. The variation in AC gain is now fixed and the input analog bandwidth improved.

  16. Novel real-time alignment and calibration of the LHCb detector in Run II

    CERN Document Server

    Xu, Zhirui

    2015-01-01

    An automatic real-time alignment and calibration strategy of the LHCb detector was developed for the Run II. Thanks to the online calibration, tighter event selection criteria can be used in the trigger. Furthermore, the online calibration facilitates the use of hadronic particle identification using the Ring Imaging Cherenkov (RICH) detectors at the trigger level. The motivation for a real-time alignment and calibration of the LHCb detector is discussed from both the operational and physics performance points of view. Specific challenges of this novel configuration are discussed, as well as the working procedures of the framework and its performance.

  17. Search for a TeV Component of GRBs using the Milagrito Detector

    CERN Document Server

    Atkins, R; Berley, D; Chen, M L; Coyne, D G; Delay, R S; Dingus, B L; Dorfan, D E; Ellsworth, R W; Evans, D; Falcone, A D; Fleysher, L; Fleysher, R; Gisler, G; Goodman, J A; Haines, T J; Hoffman, C M; Hugenberger, S; Kelley, L A; Leonor, I; Macri, J R; McConnell, M; McCullough, J F; McEnery, J E; Miller, R S; Mincer, A I; Morales, M F; Némethy, P; Ryan, J M; Schneider, M; Shen, B; Shoup, A L; Sinnis, G; Smith, A J; Sullivan, G W; Thompson, T N; Tümer, T O; Wang, K; Wascko, M O; Westerhoff, S; Williams, D A; Yang, T; Yodh, G B

    1999-01-01

    Observing gamma ray bursts (GRBs) in the TeV energy range can be extremely valuable in providing insight to GRB radiation mechanisms and in constraining source distances. The Milagrito detector was an air shower array which used the water Cherenkov technique to search for TeV sources. Data from this detector was analyzed to look for a TeV component of GRBs coincident with low energy -rays detected by the BATSE instrument on the Compton Gamma Ray Observatory. A sample of 54 BATSE GRBs which were in the field of view of the Milagrito detector during its lifetime (February 1997 to May 1998) was used.

  18. Study of a prototype module of a precision time-of-flight detector for particle identification at low momentum

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00388630

    In this thesis, Time Of internally Reflected Cherenkov light detector (TORCH), proposed for the LHCb Upgrade to perform three-sigma separation between kaon and pion up to 10$\\ \\rm{GeV}/\\textit{c}$, was studied. TORCH is designed to add significant particle identification capability to the existing LHCb system based on two gas Ring Imaging Cherenkov detectors. TORCH would be placed at $\\sim$ 10 m from the interaction point, where the flight time difference between a primary pion and kaon is 37.5 ps. TORCH will give a pion-kaon separation of three sigma at 10$\\ \\rm{GeV}/\\textit{c}$ from the flight time using the Cherenkov photons generated by the charged particle in a 1 cm-thick quartz plate. In order to calculate accurately the flight time in a busy LHCb environment, Cherenkov angle and photon detection time information, as well as the momentum information from the tracking detector are included in the analysis. For the required TORCH performance, the flight time difference must be measured with a resolution o...

  19. Hadron blind detector. Final report, FY1994 and 1995

    Energy Technology Data Exchange (ETDEWEB)

    Chen, M.

    1997-10-25

    The authors have been developing a novel threshold Cherenkov detector, consisting of a gas radiator followed by a UV photosensitive wire chamber using CsI photocathodes. The photo-detector lies directly in the particle path and is thus required to have single photo-electron sensitivity and yet to be insensitive to the passage of a charged particle. In addition, the detector should be made of low mass material to minimize the effect of multiple scatterings. The proposed threshold Cherenkov counters are called Hadron Blind Detectors (HBDs) because they are blind to low energy hadrons which have lower speed {beta} for given momentum p than that of electrons. HBDs can be used in colliders, especially heavy ion hadron colliders (RHIC, LHC), which have huge {number_sign} of hadrons produced per event, to select electrons by being blind to low-momentum hadrons. The authors have studied two different methods to build HBDs described as follows: (1) windowless configuration; (2) thin window configuration. The authors describe herewith their recent experimental results on HBD research obtained with CsI photo-cathodes and HBD prototype beam testing in 1995.

  20. Implementing a Java Based GUI for RICH Detector Analysis

    Science.gov (United States)

    Lendacky, Andrew; Voloshin, Andrew; Benmokhtar, Fatiha

    2016-09-01

    The CLAS12 detector at Thomas Jefferson National Accelerator Facility (TJNAF) is undergoing an upgrade. One of the improvements is the addition of a Ring Imaging Cherenkov (RICH) detector to improve particle identification in the 3-8 GeV/c momentum range. Approximately 400 multi anode photomultiplier tubes (MAPMTs) are going to be used to detect Cherenkov Radiation in the single photoelectron spectra (SPS). The SPS of each pixel of all MAPMTs have been fitted to a mathematical model of roughly 45 parameters for 4 HVs, 3 OD. Out of those parameters, 9 can be used to evaluate the PMTs performance and placement in the detector. To help analyze data when the RICH is operational, a GUI application was written in Java using Swing and detector packages from TJNAF. To store and retrieve the data, a MySQL database program was written in Java using the JDBC package. Using the database, the GUI pulls the values and produces histograms and graphs for a selected PMT at a specific HV and OD. The GUI will allow researchers to easily view a PMT's performance and efficiency to help with data analysis and ring reconstruction when the RICH is finished.

  1. The ASTRI mini-array within the future Cherenkov Telescope Array

    Science.gov (United States)

    Vercellone, Stefano

    2016-07-01

    The Cherenkov Telescope Array (CTA) is a large collaborative effort aimed at the design and operation of an observatory dedicated to very high-energy gamma-ray astrophysics in the energy range from a few tens of GeV to above 100 TeV, which will yield about an order of magnitude improvement in sensitivity with respect to the current major arrays (H.E.S.S., MAGIC, and VERITAS). Within this framework, the Italian National Institute for Astrophysics is leading the ASTRI project, whose main goals are the design and installation on Mt. Etna (Sicily) of an end-to-end dual-mirror prototype of the CTA small size telescope (SST) and the installation at the CTA Southern site of a dual-mirror SST mini-array composed of nine units with a relative distance of about 300 m. The innovative dual-mirror Schwarzschild-Couder optical solution adopted for the ASTRI Project allows us to substantially reduce the telescope plate-scale and, therefore, to adopt silicon photo-multipliers as light detectors. The ASTRI mini-array is a wider international effort. The mini-array, sensitive in the energy range 1-100 TeV and beyond with an angular resolution of a few arcmin and an energy resolution of about 10-15%, is well suited to study relatively bright sources (a few × 10-12 erg cm-2 s-1 at 10 TeV) at very high energy. Prominent sources such as extreme blazars, nearby well-known BL Lac objects, Galactic pulsar wind nebulae, supernovae remnants, micro-quasars, and the Galactic Center can be observed in a previously unexplored energy range. The ASTRI mini-array will extend the current IACTs sensitivity well above a few tens of TeV and, at the same time, will allow us to compare our results on a few selected targets with those of current (HAWC) and future high-altitude extensive air-shower detectors.

  2. Monte Carlo design studies for the Cherenkov Telescope Array

    CERN Document Server

    Bernlöhr, K; Becherini, Y; Bigas, O Blanch; Carmona, E; Colin, P; Decerprit, G; Di Pierro, F; Dubois, F; Farnier, C; Funk, S; Hermann, G; Hinton, J A; Humensky, T B; Khélifi, B; Kihm, T; Komin, N; Lenain, J -P; Maier, G; Mazin, D; Medina, M C; Moralejo, A; Nolan, S J; Ohm, S; Wilhelmi, E de Oña; Parsons, R D; Arribas, M Paz; Pedaletti, G; Pita, S; Prokoph, H; Rulten, C B; Schwanke, U; Shayduk, M; Stamatescu, V; Vallania, P; Vorobiov, S; Wischnewski, R; Yoshikoshi, T; Zech, A

    2012-01-01

    The Cherenkov Telescopes Array (CTA) is planned as the future instrument for very-high-energy (VHE) gamma-ray astronomy with a wide energy range of four orders of magnitude and an improvement in sensitivity compared to current instruments of about an order of magnitude. Monte Carlo simulations are a crucial tool in the design of CTA. The ultimate goal of these simulations is to find the most cost-effective solution for given physics goals and thus sensitivity goals or to find, for a given cost, the solution best suited for different types of targets with CTA. Apart from uncertain component cost estimates, the main problem in this procedure is the dependence on a huge number of configuration parameters, both in specifications of individual telescope types and in the array layout. This is addressed by simulation of a huge array intended as a superset of many different realistic array layouts, and also by simulation of array subsets for different telescope parameters. Different analysis methods -- in use with cu...

  3. A Topological Trigger System for Imaging Atmospheric-Cherenkov Telescopes

    CERN Document Server

    Schroedter, M; Byrum, K; Drake, G; Duke, C; Holder, J; Imran, A; Madhavan, A; Krennrich, F; Kreps, A; Smith, A

    2009-01-01

    A fast trigger system is being designed as a potential upgrade to VERITAS, or as the basis for a future array of imaging atmospheric-Cherenkov telescopes such as AGIS. The scientific goal is a reduction of the energy threshold by a factor of 2 over the current threshold of VERITAS of around 130 GeV. The trigger is being designed to suppress both accidentals from the night-sky background and cosmic rays. The trigger uses field-programmable gate arrays (FPGAs) so that it is adaptable to different observing modes and special physics triggers, e.g. pulsars. The trigger consists of three levels: The level 1 (L1.5) trigger operating on each telescope camera samples the discriminated pixels at a rate of 400 MHz and searches for nearest-neighbor coincidences. In L1.5, the received discriminated signals are delay-compensated with an accuracy of 0.078 ns, facilitating a short coincidence time-window between any nearest neighbor of 5 ns. The hit pixels are then sent to a second trigger level (L2) that parameterizes the ...

  4. Cherenkov radiation with massive, C P T -violating photons

    Science.gov (United States)

    Colladay, Don; McDonald, Patrick; Potting, Robertus

    2016-06-01

    The source of C P T violation in the photon sector of the Standard Model Extension arises from a Chern-Simons-like contribution that involves a coupling to a fixed background vector field kAF μ . These Lorentz- and C P T -violating photons have well-known theoretical issues that arise from missing states at low momenta when kAF μ is timelike. In order to make the theory consistent, a tiny mass for the photon can be introduced, well below current experimental bounds. The implementation of canonical quantization can then be implemented as in the C P T -preserving case by using the Stückelberg mechanism. We explicitly construct a covariant basis of properly normalized polarization vectors at fixed three-momentum satisfying the momentum space field equations, in terms of which the vector field can be expanded. As an application of the theory, we calculate the Cherenkov radiation rate for the case of purely timelike kAF μ and find a radiation rate at high energies that has a contribution that does not depend on the mass used to regulate the photons.

  5. Redshift measurement of Fermi Blazars for the Cherenkov Telescope Array

    CERN Document Server

    Goldoni, P; Boisson, C; Cotter, G; Williams, D A

    2015-01-01

    Blazars are active galactic nuclei, and the most numerous High Energy (HE) and Very High Energy (VHE) gamma-ray emitters. Their optical emission is often dominated by non-thermal, and, in the case of BL Lacs, featureless continuum radiation. This renders the determination of their redshift extremely difficult. Indeed, as of today only about 50 % of gamma-ray blazars have a measured spectroscopic redshift. The knowledge of redshift is fundamental because it allows the precise modeling of the VHE emission and also of its interaction with the extragalactic background light (EBL). The beginning of the Cherenkov Telescope Array (CTA) operations in the near future will allow the detection of several hundreds of new BL Lacs. Using the first Fermi catalogue of sources above 10 GeV (1FHL), we performed simulations which demonstrate that at least half of the 1FHL BL Lacs detectable by CTA will not have a measured redshift. Indeed the organization of observing campaigns to measure the redshift of these blazars has been ...

  6. All-fiber femtosecond Cherenkov laser at visible wavelengths

    DEFF Research Database (Denmark)

    Liu, Xiaomin; Lægsgaard, Jesper; Møller, Uffe Visbech

    2013-01-01

    for the generated CR pulse is 160 fs. The FWHM of the AC of the input pump pulse at 1035 nm is 832 fs. The CR pulse is more than 5 times shorter than the pump pulse, as a result of the nonlinear pump pulse compression in the CR fiber link. We are currently working on achieving an even broader electrical tunability......Fiber-optic Cherenkov radiation (CR), also known as dispersive wave generation or non-solitonic radiation, is produced in small-core photonic crystal fibers (PCF) when a soliton perturbed by fiber higher-order dispersion co-propagates with a dispersive wave fulfilling a certain phase...... electrically tunable femtosecond CR output in the visible (VIS) spectral range of 580-630 nm, with the 3 dB spectral bandwidth not exceeding 36 nm, with average power in the milliwatt range. Relative intensity noise (RIN) of this laser, affecting the sensitivity of bio-imaging and microscopy systems, is found...

  7. Design constraints on Cherenkov telescopes with Davies-Cotton reflectors

    CERN Document Server

    Bretz, Thomas

    2013-01-01

    This paper discusses the construction of high-performance ground-based gamma-ray Cherenkov telescopes with a Davies-Cotton reflector. For the design of such telescopes, usually physics constrains the field-of-view, while the photo-sensor size is defined by limited options. Including the effect of light-concentrators in front of the photo sensor, it is demonstrated that these constraints are enough to mutually constrain all other design parameters. The dependability of the various design parameters naturally arises once a relationship between the value of the point-spread functions at the edge of the field-of-view and the pixel field-of-view is introduced. To be able to include this constraint into a system of equations, an analytical description for the point-spread function of a tessellated Davies-Cotton reflector is derived from Taylor developments and ray-tracing simulations. Including higher order terms renders the result precise on the percent level. Design curves are provided within the typical phase sp...

  8. An outdoor test facility for the Cherenkov Telescope Array mirrors

    CERN Document Server

    Medina, M C; Maya, J; Mancilla, A; Larrarte, J J; Rasztocky, E; Benitez, M; Dipold, J; Platino, M

    2013-01-01

    The Cherenkov Telescopes Array (CTA) is planned to be an Observatory for very high energy gamma ray astronomy and will consist of several tens of telescopes which account for a reflective surface of more than 10000 m$^2$. The mirrors of these telescopes will be formed by a set of facets. Different technological solutions, for a fast and cost efficient production of light-weight mirror facets are under test inside the CTA Consortium. Most of them involve composite structures whose behavior under real observing conditions is not yet fully tested. An outdoor test facility has been built in one of the candidate sites for CTA, in Argentina (San Antonio de los Cobres [SAC], 3600m a.s.l) in order to monitor the optical and mechanical properties of these facets exposed to the local atmospheric conditions for a given period of time. In this work we present the preliminary results of the first Middle Size Telescope (MST) mirror-monitoring campaign, started in 2013.

  9. A Smart Pixel Camera for future Cherenkov Telescopes

    CERN Document Server

    Hermann, G; Glück, B; Hauser, D; Hermann, German; Carrigan, Svenja; Gl\\"uck, Bernhard; Hauser, Dominik

    2005-01-01

    The Smart Pixel Camera is a new camera for imaging atmospheric Cherenkov telescopes, suited for a next generation of large multi-telescope ground based gamma-ray observatories. The design of the camera foresees all electronics needed to process the images to be located inside the camera body at the focal plane. The camera has a modular design and is scalable in the number of pixels. The camera electronics provides the performance needed for the next generation instruments, like short signal integration time, topological trigger and short trigger gate, and at the same time the design is optimized to minimize the cost per channel. In addition new features are implemented, like the measurement of the arrival time of light pulses in the pixels on the few hundred psec timescale. The buffered readout system of the camera allows to take images at sustained rates of O(10 kHz) with a dead-time of only about 0.8 % per kHz.

  10. Status of the Cherenkov Telescope Array's Large Size Telescopes

    CERN Document Server

    Cortina, J

    2015-01-01

    The Cherenkov Telescope Array (CTA) observatory, will be deployed over two sites in the two hemispheres. Both sites will be equipped with four Large Size Telescopes (LSTs), which are crucial to achieve the science goals of CTA in the 20-200 GeV energy range. Each LST is equipped with a primary tessellated mirror dish of 23 m diameter, supported by a structure made mainly of carbon fibre reinforced plastic tubes and aluminum joints. This solution guarantees light weight (around 100 tons), essential for fast repositioning to any position in the sky in <20 seconds. The camera is composed of 1855 PMTs and embeds the control, readout and trigger electronics. The detailed design is now complete and production of the first LST, which will serve as a prototype for the remaining seven, is well underway. In 2016 the first LST will be installed at the Roque de los Muchachos Observatory on the Canary island of La Palma (Spain). In this talk we will outline the technical solutions adopted to fulfill the design requirem...

  11. Cherenkov Radiation with Massive, CPT-violating Photons

    CERN Document Server

    Colladay, Don; Potting, Robertus

    2016-01-01

    The source of CPT-violation in the photon sector of the Standard Model Extension arises from a Chern-Simons-like contribution that involves a coupling to a fixed background vector field $k_{AF}^\\mu$. These Lorentz- and CPT-violating photons have well-known theoretical issues that arise from missing states at low momenta when $k_{AF}^\\mu$ is timelike. In order to make the theory consistent, a tiny mass for the photon can be introduced, well below current experimental bounds. The implementation of canonical quantization can then be implemented as in the CPT-preserving case by using the St\\"uckelberg mechanism. We explicitly construct a covariant basis of properly-normalized polarization vectors at fixed three-momentum satisfying the momentum space field equations, in terms of which the vector field can be expanded. As an application of the theory, we calculate the Cherenkov radiation rate for the case of purely timelike $k_{AF}^\\mu$, and find a radiation rate at high energies that has a contribution that does n...

  12. The Medium Size Telescopes of the Cherenkov Telescope Array

    CERN Document Server

    Pühlhofer, G

    2016-01-01

    The Cherenkov Telescope Array (CTA) is the planned next-generation instrument for ground-based gamma-ray astronomy, covering a photon energy range of ~20 GeV to above 100 TeV. CTA will consist of the order of 100 telescopes of three sizes, installed at two sites in the Northern and Southern Hemisphere. This contribution deals with the 12 meter Medium Size Telescopes (MST) having a single mirror (modified Davies-Cotton, DC) design. In the baseline design of the CTA arrays, 25 MSTs in the South and 15 MSTs in the North provide the necessary sensitivity for CTA in the core energy range of 100 GeV to 10 TeV. DC-MSTs will be equipped with photomultiplier (PMT)-based cameras. Two options are available for these focal plane instruments, that will be provided by the FlashCam and the NectarCAM sub-consortia. In this contribution, a short introduction to the projects and their status is given.

  13. Pixel Detectors

    OpenAIRE

    Wermes, Norbert

    2005-01-01

    Pixel detectors for precise particle tracking in high energy physics have been developed to a level of maturity during the past decade. Three of the LHC detectors will use vertex detectors close to the interaction point based on the hybrid pixel technology which can be considered the state of the art in this field of instrumentation. A development period of almost 10 years has resulted in pixel detector modules which can stand the extreme rate and timing requirements as well as the very harsh...

  14. A facility to evaluate the focusing performance of mirrors for Cherenkov Telescopes

    CERN Document Server

    Canestrari, Rodolfo; Bonnoli, Giacomo; Farisato, Giancarlo; Lessio, Luigi; Rodeghiero, Gabriele; Spiga, Rossella; Toso, Giorgio; Pareschi, Giovanni

    2015-01-01

    With the advent of the imaging atmospheric Cherenkov technique in late 1980's, ground-based observations of Very High-Energy gamma rays came into reality. Since the first source detected at TeV energies in 1989 by Whipple, the number of high energy gamma-ray sources has rapidly grown up to more than 150 thanks to the second generation experiments like MAGIC, H.E.S.S. and VERITAS. The Cherenkov Telescope Array observatory is the next generation of Imaging Atmospheric Cherenkov Telescopes, with at least 10 times higher sensitivity than current instruments. Cherenkov Telescopes have to be equipped with optical dishes of large diameter -- in general based on segmented mirrors -- with typical angular resolution of a few arc-minutes. To evaluate the mirror's quality specific metrological systems are required that possibly take into account the environmental conditions in which typically Cherenkov telescopes operate (in open air without dome protection). For this purpose a new facility for the characterization of mi...

  15. LATTES: a new gamma-ray detector concept for South America

    Directory of Open Access Journals (Sweden)

    Assis P.

    2017-01-01

    Full Text Available Currently the detection of Very High Energy gamma-rays for astrophysics rely on the measurement of the Extensive Air Showers (EAS either using Cherenkov detectors or EAS arrays with larger field of views but also larger energy thresholds. In this talk we present a novel hybrid detector concept for a EAS array with an improved sensitivity in the lower energies (~ 100 GeV. We discuss its main features, capabilities and present preliminary results on its expected perfomances and sensitivities.This wide field of view experiment is planned to be installed at high altitude in South America making it a complementary project to the planned Cherenkov telescope experiments and a powerful tool to trigger further observations of variable sources and to detect transients phenomena.

  16. Optical Detectors

    Science.gov (United States)

    Tabbert, Bernd; Goushcha, Alexander

    Optical detectors are applied in all fields of human activities from basic research to commercial applications in communication, automotive, medical imaging, homeland security, and other fields. The processes of light interaction with matter described in other chapters of this handbook form the basis for understanding the optical detectors physics and device properties.

  17. Metal Detectors.

    Science.gov (United States)

    Harrington-Lueker, Donna

    1992-01-01

    Schools that count on metal detectors to stem the flow of weapons into the schools create a false sense of security. Recommendations include investing in personnel rather than hardware, cultivating the confidence of law-abiding students, and enforcing discipline. Metal detectors can be quite effective at afterschool events. (MLF)

  18. Improving Light Collection Efficiency in HAWC Detector Tanks

    Science.gov (United States)

    Kudler-Flam, Jonah; HAWC Collaboration Collaboration

    2017-01-01

    The High Altitude Water Cherenkov (HAWC) Observatory was designed to detect air showers produced by gamma-rays and cosmic-rays between 100 GeV and 100 TeV. The detector is composed of 300 water tanks with four photomultipliers (PMTs) located at the bottom of each tank. When charged particles from air showers enter the tanks, the Cherenkov light produced by the particles is detected by the PMTs. However, much of the Cherenkov light is lost due to the small collection areas of the PMTs. To increase the collection area of the photosensors, we investigate light collectors composed of wavelength-shifting fibers. We have constructed a simple concentrator in the lab using two silicon photomultipliers and 1 mm optical fibers coated with a wavelength-shifting layer, and simulated the response of the setup using PVTrace, a Python package designed to raytrace photons in luminescent concentrators. We compare our simulations to results obtained in the laboratory and find that the concentration gain of the fiber system scales linearly with the number of fibers. This project was supported in part by NSF grant NSF-PHY 1460352.

  19. Testing of photomultiplier tubes for use in the surface detector of the Pierre Auger observatory

    Energy Technology Data Exchange (ETDEWEB)

    Barnhill, D. [Department of Physics and Astronomy, UCLA, Los Angeles, CA 90095-1547 (United States)], E-mail: david.scott.barnhill@gmail.com; Suarez, F. [INFN, Universita degli Studi di Torino (Italy)], E-mail: fedesuarez@auger.org.ar; Arisaka, K. [Department of Physics and Astronomy, UCLA, Los Angeles, CA 90095-1547 (United States); Garcia, B. [UTN-FRM Mendoza (Argentina); Gongora, J.P. [UTN-FRSR San Rafael (Argentina); Lucero, A.; Navarro, I. [UTN-FRM Mendoza (Argentina); Ohnuki, T. [Department of Physics and Astronomy, UCLA, Los Angeles, CA 90095-1547 (United States); Risi, A. [UTN-FRSR San Rafael (Argentina); Tripathi, A. [Department of Physics and Astronomy, UCLA, Los Angeles, CA 90095-1547 (United States)

    2008-07-01

    In the array of water Cherenkov detectors of the Pierre Auger Observatory, 4800 large photomultiplier tubes (PMTs) will be used. Before being deployed, each PMT is evaluated to check that various parameters, such as the linearity, dark noise, and gain, fall within a specified range. The large scale test system, designed and constructed for this purpose, is capable of testing multiple large PMTs simultaneously. The test system and the results of the tests for the first 3964 PMTs are presented in this paper.

  20. Proposal for multi-anode photo multiplier tubes as photo detectors for the LHCb RICH

    CERN Document Server

    Muheim, F; Katvars, S; Wotton, S; Albrecht, E; Bernet, R; Eisenhardt, S; Muheim, F; Playfer, S; Cuneo, S; Petrolini, A; Sannino, M; Easo, S; Halley, A; Barber, G; Duane, A; Price, D; Simmons, B; Websdale, D; Calvi, M; Matteuzzi, C; Paganoni, M; Bibby, J; Charles, M; Harnew, N; Libby, J; Rademacker, J; Smale, N; Topp-Jorgensen, S; Wilkinson, G; Baker, J; Densham, C; French, M

    2001-01-01

    We propose to use the Multianode Photo Multiplier Tubes (MAPMT) as the photosensitive device for the Ring Imaging Cherenkov (RICH) detector in the LHCb experiment. We demonstrate that MAPMT meet the specifications which are required to perform excellent particle identification of charged tracks over the full acceptance. A baseline design is presented. At the end of 1999 the MAPMT has been selected as backup choice for the photodetectors. We present the implication of this decision on the baseline design.

  1. Solar panels as cosmic-ray detectors

    CERN Document Server

    Stella, Carlo; Assis, Pedro; Brogueira, Pedro; Santo, Catarina Espirito; Goncalves, Patricia; Pimenta, Mario; De Angelis, Alessandro

    2014-01-01

    Due to fundamental limitations of accelerators, only cosmic rays can give access to centre-of- mass energies more than one order of magnitude above those reached at the LHC. In fact, extreme energy cosmic rays (1018 eV - 1020 eV) are the only possibility to explore the 100 TeV energy scale in the years to come. This leap by one order of magnitude gives a unique way to open new horizons: new families of particles, new physics scales, in-depth investigations of the Lorentz symmetries. However, the flux of cosmic rays decreases rapidly, being less than one particle per square kilometer per year above 1019 eV: one needs to sample large surfaces. A way to develop large-effective area, low cost, detectors, is to build a solar panel-based device which can be used in parallel for power generation and Cherenkov light detection. Using solar panels for Cherenkov light detection would combine power generation and a non-standard detection device.

  2. Cherenkov light detection as a velocity selector for uranium fission products at intermediate energies

    Science.gov (United States)

    Yamaguchi, T.; Enomoto, A.; Kouno, J.; Yamaki, S.; Matsunaga, S.; Suzaki, F.; Suzuki, T.; Abe, Y.; Nagae, D.; Okada, S.; Ozawa, A.; Saito, Y.; Sawahata, K.; Kitagawa, A.; Sato, S.

    2014-12-01

    The in-flight particle separation capability of intermediate-energy radioactive ion (RI) beams produced at a fragment separator can be improved with the Cherenkov light detection technique. The cone angle of Cherenkov light emission varies as a function of beam velocity. This can be exploited as a velocity selector for secondary beams. Using heavy ion beams available at the HIMAC synchrotron facility, the Cherenkov light angular distribution was measured for several thin radiators with high refractive indices (n = 1.9 ~ 2.1). A velocity resolution of ~10-3 was achieved for a 56Fe beam with an energy of 500 MeV/nucleon. Combined with the conventional rigidity selection technique coupled with energy-loss analysis, the present method will enable the efficient selection of an exotic species from huge amounts of various nuclides, such as uranium fission products at the BigRIPS fragment separator located at the RI Beam Factory.

  3. Quantum calculation of the Vavilov-Cherenkov radiation by twisted electrons

    Science.gov (United States)

    Ivanov, I. P.; Serbo, V. G.; Zaytsev, V. A.

    2016-05-01

    We present a detailed quantum electrodynamical description of Vavilov-Cherenkov radiation emitted by a relativistic twisted electron in the transparent medium. Simple expressions for the spectral and spectral-angular distributions as well as for the polarization properties of the emitted radiation are obtained. Unlike the plane-wave case, the twisted electron produces radiation within the annular angular region, with enhancement towards its boundaries. Additionally, the emitted photons can have linear polarization not only in the scattering plane but also in the orthogonal direction. We find that the Vavilov-Cherenkov radiation emitted by an electron in a superposition of two vortex states exhibits a strong azimuthal asymmetry. Thus, the Vavilov-Cherenkov radiation offers itself as a convenient diagnostic tool of such electrons and complements the traditional microscopic imaging.

  4. Quantum calculation of the Vavilov-Cherenkov radiation by twisted electrons

    CERN Document Server

    Ivanov, I P; Zaytsev, V A

    2016-01-01

    We present the detailed quantum electrodynamical description of Vavilov-Cherenkov radiation emitted by a relativistic twisted electron in the transparent medium. Simple expressions for the spectral and spectral-angular distributions as well as for the polarization properties of the emitted radiation are obtained. Unlike the plane-wave case, the twisted electron produces radiation within the annular angular region, with enhancement towards its boundaries. Additionally, the emitted photons can have linear polarization not only in the scattering plane but also in the orthogonal direction. We find that the Vavilov-Cherenkov radiation emitted by an electron in a superposition of two vortex states exhibits a strong azimuthal asymmetry. Thus, the Vavilov-Cherenkov radiation offers itself as a convenient diagnostic tool of such electrons and complements the traditional microscopic imaging.

  5. Prototype Test Results of the Solar Tower Atmospheric Cherenkov Effect Experiment (STACEE)

    CERN Document Server

    Williams, D A; Manna, D S; Marion, G M; Ong, R A; Tunner, T O; Dragovan, M; Oser, S; Chantel, M C; Bhattacharya, D P; Covault, C E; Fernholx, R

    1998-01-01

    There are currently no experiments, either satellite or ground-based, that are sensitive to astrophysical gamma-rays at energies between 20 and 250 GeV. We are developing the Solar Tower Atmospheric Cherenkov Effect Experiment (STACEE) to explore this energy range. STACEE will use heliostat mirrors at a solar research facility to collect Cherenkov light from extensive air showers produced by high energy gamma-rays. Here we report on the results of prototype test work at the solar facility of Sandia National Laboratories (Albuquerque, NM). The work demonstrates that the facility is suitable for use as an astrophysical observatory. In addition, using a full scale prototype of part of STACEE, we detected atmospheric Cherenkov radiation at energies lower than any other ground-based experiment to date.

  6. Neutrino superluminality without Cherenkov-like processes in Finslerian special relativity

    CERN Document Server

    Chang, Zhe; Wang, Sai; 10.1016/j.physletb.2012.03.002

    2012-01-01

    Recently, Cohen and Glashow [A.G. Cohen, S.L. Glashow, Phys. Rev. Lett. {\\bf 107}, 181803 (2011)] pointed out that the superluminal neutrinos reported by the OPERA would lose their energy rapidly via the Cherenkov-like process. The Cherenkov-like process for the superluminal particles would be forbidden if the principle of special relativity holds in any frame instead violated with a preferred frame. We have proposed that the Finslerian special relativity could account for the data of the neutrino superluminality (arXiv:1110.6673[hep-ph]). The Finslerian special relativity preserves the principle of special relativity and involves a preferred direction while consists with the causality. In this paper, we prove that the energy-momentum conservation is preserved and the energy-momentum is well defined in Finslerian special relativity. The Cherenkov-like process is forbidden in the Finslerian special relativity. Thus, the superluminal neutrinos would not lose energy in their distant propagation.

  7. Fabrication of the CALDER light detectors

    Science.gov (United States)

    Colantoni, I.; Bellini, F.; Cardani, L.; Casali, N.; Castellano, M. G.; Coppolecchia, A.; Cosmelli, C.; Cruciani, A.; D`Addabbo, A.; Di Domizio, S.; Martinez, M.; Tomei, C.; Vignati, M.

    2016-07-01

    CALDER (Cryogenic wide-Area Light Detectors with Excellent Resolution) is a project for the development of large area phonon mediated KIDs (Kinetic Inductance Detectors), for the detection of Cherenkov radiation emitted in TeO2 bolometers to search for neutrinoless double beta decay (0 νββ). The KIDs are superconducting detectors made of high quality factor superconducting resonators, which are coupled to a transmission line for signal readout. We designed and fabricated KIDs using aluminum. The Al thin films (40 nm) were evaporated on Si(100) high resistivity silicon wafers using an electron beam evaporator in a HV chamber. In this work we report the steps of the fabrication process. All devices are made in direct-write using Electron Beam Lithography (EBL), positive tone resist poly-methyl methacrylate (PMMA) and lift off process. In order to improve the sensitivity of the detectors we have started recently to use sub-stoichiometric TiN deposited by means of DC magnetron sputtering and we will optimize a different fabrication process.

  8. Large-aperture hybrid photo-detector

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Y. [Institute for Particle and Nuclear Studies, The Graduate University for Advanced Studies, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Electron Tube Division, Hamamatsu Photonics K.K., 314-5 Shimokanzo, Iwata City 438-0193, Shizuoka (Japan)], E-mail: kawaiy@post.kek.jp; Nakayama, H.; Kusaka, A.; Kakuno, H.; Abe, T.; Iwasaki, M.; Aihara, H. [Department of Physics, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Tanaka, M. [Institute for Particle and Nuclear Studies, High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Shiozawa, M. [Institute for Cosmic Ray Research, University of Tokyo, Higashi-Mozumi, Kamioka-cho, Hida City, Gifu 506-1205 (Japan); Kyushima, H.; Suyama, M. [Electron Tube Division, Hamamatsu Photonics K.K., 314-5 Shimokanzo, Iwata City 438-0193, Shizuoka (Japan)

    2007-08-21

    We have developed the first complete large-aperture (13-inch diameter) hybrid photo-detector (HPD). The withstanding voltage problem has been overcome and we were able to attain an HPD operating voltage of +20 kV. Adoption of our newly developed backside illumination avalanche diode (AD) was also critical in successfully countering the additional problem of an increase in AD leakage after the activation process. We observed single photon signal timing jitter of under 450 ps in FWHM, electron transit time of {approx}12 ns, and clear pulse height separation up to several photoelectron peaks, all greatly superior to the performance of any conventional large-aperture photomultiplier tubes (PMTs). In addition, our HPD has a much simpler structure than conventional large-aperture PMTs, which simplifies mass production and lowers manufacturing cost. We believe that these attributes position our HPD as the most suitable photo-detector for the next generation mega-ton class water-Cherenkov detector, which is expected to be more than 20x larger than the Super-Kamiokande (SK) detector.

  9. The CMS Beam Halo Monitor Detector System

    CERN Document Server

    Stifter, Kelly

    2015-01-01

    A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of collimators before the CMS experiment and from beam gas interactions. The BHM detector uses the directional nature of Cherenkov radiation and event timing to select particles coming from the direction of the beam and to suppress those originating from the interaction point. It consists of 40 quartz rods, placed on each side of the CMS detector, coupled to UV sensitive PMTs. For each bunch crossing the PMT signal is digitized by a charge integrating ASIC and the arrival time of the signal is recorded. The data are processed in real time to yield a precise measurement of per-bunch-crossing background rate. This measurement is made available to CMS and the LHC, to provide real-time feedback on the beam quality and to improve the efficiency of data taking. Here, I present the detector...

  10. The surface detector system of the Pierre Auger Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Allekotte, I. [Instituto Balseiro and Centro Atomico Bariloche (U.N. Cuyo and CNEA, CONICET), 8400 Bariloche (Argentina)], E-mail: ingo@cab.cnea.gov.ar; Barbosa, A.F. [CBPF, Rua Xavier Sigaud 150, Rio de Janeiro (Brazil); Bauleo, P. [Colorado State University, Fort Collins, CO 80523 (United States); Bonifazi, C. [CBPF, Rua Xavier Sigaud 150, Rio de Janeiro (Brazil); Civit, B. [Universidad Tecnologica Nacional Regional Mendoza, Mendoza (Argentina); Escobar, C.O. [Departamento de Raios Cosmicos, Instituto de Fisica, Universidade Estadual de Campinas, CP 6165, 13084-971, Campinas SP (Brazil); Garcia, B. [Universidad Tecnologica Nacional Regional Mendoza, Mendoza (Argentina); Guedes, G. [Universidade Estadual de Feira de Santana (UEFS), Av. Universitaria Km 03 da BR 116, Campus Universitario, 44031-460 Feira de Santana BA (Brazil); Gomez Berisso, M. [Instituto Balseiro and Centro Atomico Bariloche (U.N. Cuyo and CNEA, CONICET), 8400 Bariloche (Argentina); Harton, J.L. [Colorado State University, Fort Collins, CO 80523 (United States); Healy, M. [Department of Physics and Astronomy, University of California, Los Angeles (UCLA), Los Angeles, CA 90095 (United States); Kaducak, M.; Mantsch, P.; Mazur, P.O.; Newman-Holmes, C. [Fermi National Accelerator Laboratory Batavia, IL (United States); Pepe, I. [Universidade Federal da Bahia, Campus de Odina, 40210-340 Salvador BA (Brazil); Rodriguez-Cabo, I. [Dpto. Fisica de Particulas, Universidad de Santiago de Compostela, 15706 Santiago de Compostela (Spain); Salazar, H. [Benemerita Universidad Autonoma de Puebla (BUAP), Ap. Postal J-48, 72500 Puebla, Puebla (Mexico); Smetniansky-De Grande, N. [Laboratorio Tandar, Comision Nacional de Energia Atomica and CONICET, Av. Gral. Paz 1499 (1650) San Martin, Buenos Aires (Argentina); Warner, D. [Colorado State University, Fort Collins, CO 80523 (United States)

    2008-03-01

    The Pierre Auger Observatory is designed to study cosmic rays with energies greater than 10{sup 19}eV. Two sites are envisaged for the observatory, one in each hemisphere, for complete sky coverage. The southern site of the Auger Observatory, now approaching completion in Mendoza, Argentina, features an array of 1600 water-Cherenkov surface detector stations covering 3000km{sup 2}, together with 24 fluorescence telescopes to record the air shower cascades produced by these particles. The two complementary detector techniques together with the large collecting area form a powerful instrument for these studies. Although construction is not yet complete, the Auger Observatory has been taking data stably since January 2004 and the first physics results are being published. In this paper we describe the design features and technical characteristics of the surface detector stations of the Pierre Auger Observatory.

  11. Particle identification below threshold with AMS-02 RICH detector

    CERN Document Server

    Li, Ziyuan; Giovacchini, Francesca; Hoffman, Julia; Haino, Sadakazu

    2016-01-01

    The Alpha Magnetic Spectrometer (AMS-02) was installed on the International Space Station (ISS) and it has been collecting data successfully since May 2011. The main goals of AMS-02 are the search for cosmic anti-matter, dark matter and the precise measurement of the relative abundance of elements and isotopes in galactic cosmic rays. In order to identify particle properties, AMS-02 includes several specialized sub-detectors. Among them, the AMS-02 Ring Imaging Cherenkov detector (RICH) is designed to provide a very precise measurement of the velocity and electric charge of particles. A method to reject the dominant electron background in antiproton identification using the AMS-02 RICH detector as a veto will be described. By using the collected cosmic-rays data, electron contamination can be well suppressed within 3% with $\\beta \\approx 1$, while keeping 76% efficiency for antiprotons below the threshold.

  12. The Surface Detector System of the Pierre Auger Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Allekotte, I.; Barbosa, A.F.; Bauleo, P.; Bonifazi, C.; Civit, B.; Escobar, C.O.; Garcia, B.; Guedes, G.; Gomez Berisso, M.; Harton, J.L.; Healy, M.; /Cuyo U. /Buenos Aires, CONICET /Natl. Tech. U., San Rafael /Campinas State U. /UEFS, Feira de Santana /Bahia U. /BUAP, Puebla /Santiago de Compostela U. /Fermilab /UCLA /Colorado State U.

    2007-11-01

    The Pierre Auger Observatory is designed to study cosmic rays with energies greater than 10{sup 19} eV. Two sites are envisaged for the observatory, one in each hemisphere, for complete sky coverage. The southern site of the Auger Observatory, now approaching completion in Mendoza, Argentina, features an array of 1600 water-Cherenkov surface detector stations covering 3000 km{sup 2}, together with 24 fluorescence telescopes to record the air shower cascades produced by these particles. The two complementary detector techniques together with the large collecting area form a powerful instrument for these studies. Although construction is not yet complete, the Auger Observatory has been taking data stably since January 2004 and the first physics results are being published. In this paper we describe the design features and technical characteristics of the surface detector stations of the Pierre Auger Observatory.

  13. On-site mirror facet condensation measurements for the Cherenkov Telescope Array

    Science.gov (United States)

    Dipold, J.; Medina, M. C.; García, B.; Rasztocky, E.; Mancilla, A.; Maya, J.; Larrarte, J. J.; de Souza, V.

    2016-09-01

    The Imaging Atmospheric Cherenkov Technique (IACT) has provided very important discoveries in Very High Energy (VHE) γ-ray astronomy for the last two decades, being exploited mainly by experiments such as H.E.S.S., MAGIC and VERITAS. The same technique will be used by the next generation of γ-ray telescopes, Cherenkov Telescope Array - CTA, which is conceived to be an Observatory composed by two arrays strategically placed in both hemispheres, one in the Northern and one in the Southern. Each site will consist of several tens of Cherenkov telescopes of different sizes and will be equipped with about 10000 m2 of reflective surface. Because of its large size, the reflector of a Cherenkov telescope is composed of many individual mirror facets. Cherenkov telescopes operate without any protective system from weather conditions therefore it is important to understand how the reflective surfaces behave under different environmental conditions. This paper describes a study of the behavior of the mirrors in the presence of water vapor condensation. The operational time of a telescope is reduced by the presence of condensation on the mirror surface, therefore, to control and to monitor the formation of condensation is an important issue for IACT observatories. We developed a method based on pictures of the mirrors to identify the areas with water vapor condensation. The method is presented here and we use it to estimate the time and area two mirrors had condensation when exposed to the environmental conditions in the Argentinean site. The study presented here shows important guidelines in the selection procedure of mirror technologies and shows an innovative monitoring tool to be used in future Cherenkov telescopes.

  14. The large-area hybrid-optics CLAS12 RICH detector: Tests of innovative components

    Energy Technology Data Exchange (ETDEWEB)

    Contalbrigo, M., E-mail: contalbrigo@fe.infn.it [INFN Sezione di Ferrara and University of Ferrara (Italy); Baltzell, N. [Argonne National Laboratory, IL (United States); Benmokhtar, F. [Christopher Newport University, VA (United States); Duquesne University, PA (United States); Barion, L. [INFN Sezione di Ferrara and University of Ferrara (Italy); Cisbani, E. [INFN Sezione di Roma – Gruppo Collega to Sanità (Italy); Italian National Institute of Health (Italy); El Alaoui, A. [Universidad Tecnica Federico Santa Maria, Valparaiso (Chile); Argonne National Laboratory, IL (United States); Hafidi, K. [Argonne National Laboratory, IL (United States); Hoek, M. [Glasgow University (United Kingdom); J. Gutenberg Universität, Mainz (Germany); Kubarovsky, V. [Thomas Jefferson National Laboratory, VA (United States); Lagamba, L. [INFN Sezione di Bari, University of Bari (Italy); Lucherini, V. [INFN Laboratori Nazionali di Frascati (Italy); Malaguti, R. [INFN Sezione di Ferrara and University of Ferrara (Italy); Mirazita, M. [INFN Laboratori Nazionali di Frascati (Italy); Montgomery, R. [Glasgow University (United Kingdom); INFN Laboratori Nazionali di Frascati (Italy); Movsisyan, A. [INFN Sezione di Ferrara and University of Ferrara (Italy); Musico, P. [INFN Sezione di Genova (Italy); Orecchini, D.; Orlandi, A. [INFN Laboratori Nazionali di Frascati (Italy); Pappalardo, L.L. [INFN Sezione di Ferrara and University of Ferrara (Italy); Pereira, S. [INFN Laboratori Nazionali di Frascati (Italy); and others

    2014-12-01

    A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab to study the 3D nucleon structure in the yet poorly explored valence region by deep-inelastic scattering, and to perform precision measurements in hadronization and hadron spectroscopy. The adopted solution foresees a novel hybrid optics design based on an aerogel radiator, composite mirrors and densely packed and highly segmented photon detectors. Cherenkov light will either be imaged directly (forward tracks) or after two mirror reflections (large angle tracks). The preliminary results of individual detector component tests and of the prototype performance at test-beams are reported here. - Highlights: • A novel hybrid-optics configuration was proven to work with a large RICH prototype. • Innovative RICH components were studied both in laboratory tests and test-beams. • Aerogel of large Rayleigh scattering length at n=1.05 was characterized. • Novel vs commercially available multi-anode photomultipliers were compared. • The response of SiPM matrices to Cherenkov light was tested at various temperatures.

  15. A RICH detector for hadron identification at Jlab

    Energy Technology Data Exchange (ETDEWEB)

    Mammoliti, Francesco; Cisbani, Evaristo; Cusanno, Francesco; Garibaldi, Franco; Guisa, Antonio; De Jager, Cornelis; Russo, Guiseppe; Leda Sperduto, Maria; Sutera, Concetta

    2011-08-01

    The “standard” Hall A apparatus at Jefferson Lab (TOF and aerogel threshold Cherenkov detectors) does not provide complete identification for proton, kaon and pion. To this aim, a proximity focusing C6F14/CsI RICH (Ring Image Cherenkov) detector has been designed, built, tested and operated to separate kaons from pions with a pion contamination of a few percent up to 2.4 GeV/c. Two quite different experimental investigations have benefitted of the RICH identification: on one side, the high-resolution hypernuclear spectroscopy series of experiments on carbon, beryllium and oxygen, devoted to the study of the lambda-nucleon potential. On the other side, the measurements of the single spin asymmetries of pion and kaon on a transversely polarized 3He target are of utmost interest in understanding QCD dynamics in the nucleon. We present the technical features of such a RICH detector and comment on the presently achieved performance in hadron identification.

  16. Diagnostics of Electron Beams Based on Cherenkov Radiation in an Optical Fiber

    Science.gov (United States)

    Vukolov, A. V.; Novokshonov, A. I.; Potylitsyn, A. P.; Uglov, S. R.

    2017-02-01

    The use of an optical fiber in which Cherenkov radiation is generated instead of a metal wire for scanning a beam profile allows a compact and noise-proof device for diagnostics of charged particle beams in a wide energy range to be developed. Results of experimental investigation of the yield of Vavilov-Cherenkov radiation generated in optical fibers with thickness in the range from 0.125 to 1 mm by electrons with energy of 5.7 MeV are presented.

  17. Analytical Solution for the Stopping Power of the Cherenkov Radiation in a Uniaxial Nanowire Material

    Directory of Open Access Journals (Sweden)

    Tiago A. Morgado

    2015-06-01

    Full Text Available We derive closed analytical formulae for the power emitted by moving charged particles in a uniaxial wire medium by means of an eigenfunction expansion. Our analytical expressions demonstrate that, in the absence of material dispersion, the stopping power of the uniaxial wire medium is proportional to the charge velocity, and that there is no velocity threshold for the Cherenkov emission. It is shown that the eigenfunction expansion formalism can be extended to the case of dispersive lossless media. Furthermore, in the presence of material dispersion, the optimal charge velocity that maximizes the emitted Cherenkov power may be less than the speed of light in a vacuum.

  18. About Modeling the Excitation Conditions of Cherenkov and Diffraction Radiations in Periodic Metal-dielectric Structures

    Directory of Open Access Journals (Sweden)

    G.S. Vorobjov

    2015-06-01

    Full Text Available General procedure for modeling the excitation conditions of Cherenkov and diffraction radiations in periodic metal-dielectric structures is described. It is based on the representation of the electron beam space-charge wave in the form of a dielectric waveguide surface-wave. On the experimental facility of millimeter-wave the basic modes of excitation conditions of spatial harmonics of the Cherenkov and diffraction radiations are simulated. The method is tested by comparing the numerical analysis and experimental results on the layout of the device of the orotron type - generator of diffraction radiation.

  19. Cherenkov and Fano effects at the origin of asymmetric vector mesons in nuclear media

    CERN Document Server

    Dremin, I M

    2015-01-01

    It is argued that the experimentally observed phenomenon of asymmetric vector mesons produced in nuclear media during high energy nucleus-nucleus collisions can be explained as Cherenkov and Fano effects. The mass distributions of lepton pairs created at meson decays decline from the traditional Breit-Wigner shape in the low-mass wing of the resonance. That is explained by the positive real part of the amplitude in this wing for classic Cherenkov treatment and further detalized in quantum mechanics as the interference of direct and continuum states in Fano effect. The corresponding parameters are found from the comparison with rho-meson data and admit reasonable explanation.

  20. Cherenkov terahertz surface plasmon excitation by an electron beam over an ultrathin metal film

    Science.gov (United States)

    Kumar, Pawan; Kumar, Rajeev; Rajouria, Satish Kumar

    2016-12-01

    The mechanism of Cherenkov excitation of terahertz (THz) surface plasma wave (SPW), by a relativistic electron beam propagating over an ultrathin metal film deposited on glass, is investigated. The SPW field falls off exponentially in vacuum as well as glass, while the surface plasmon resonant frequency is lowered by the reduction of film thickness. The SPW field causes density bunching of the beam leading to current modulation and generation of THz radiation via the Cherenkov interaction. The frequency of the THz decreases with the energy of the beam, whereas the growth rate increases.

  1. Reconfigurable ASIC for a Low Level Trigger System in Cherenkov Telescope Cameras

    CERN Document Server

    Gascon, David; Blanch, Oscar; Boix, Joan; Delagnes, Eric; Delgado, Carlos; Freixas, Lluís; Guilloux, Fabrice; López-Coto, Rubén; Griffiths, Scott; Martínez, Gustavo; Martínez, Oscar; Sanuy, Andreu; Tejedor, Luis Ángel

    2016-01-01

    A versatile and reconfigurable ASIC is presented, which implements two different concepts of low level trigger (L0) for Cherenkov telescopes: the Majority trigger (sum of discriminated inputs) and the Sum trigger concept (analogue clipped sum of inputs). Up to 7 input signals can be processed following one or both of the previous trigger concepts. Each differential pair output of the discriminator is also available as a LVDS output. Differential circuitry using local feedback allows the ASIC to achieve high speed (500 MHz) while maintaining good linearity in a 1 Vpp range. Experimental results are presented. A number of prototype camera designs of the Cherenkov Telescope Array (CTA) project will use this ASIC.

  2. On gravitational wave-Cherenkov radiation from photons when passing through diffused dark matters

    Science.gov (United States)

    Yi, Shu-Xu

    2017-03-01

    Analogous to Cherenkov radiation, when a particle moves faster than the propagation velocity of gravitational wave in matter (v > cg), we expect gravitational wave-Cherenkov radiation (GWCR). In the situation that a photon travels across diffuse dark matters, the GWCR condition is always satisfied, photon will thence lose its energy all along the path. This effect has long been ignored in the practice of astrophysics and cosmology without justification with serious calculation. We study this effect for the first time, and shows that this energy loss time of the photon is far longer than the Hubble time and therefore justify the practice of ignoring this effect in the context of astrophysics.

  3. A G-APD based Camera for Imaging Atmospheric Cherenkov Telescopes

    Energy Technology Data Exchange (ETDEWEB)

    Anderhub, H. [Eidgenoessische Technische Hochschule Zuerich, 8093 Zuerich (Switzerland); Backes, M. [Technische Universitaet Dortmund, 44221 Dortmund (Germany); Biland, A.; Boller, A.; Braun, I. [Eidgenoessische Technische Hochschule Zuerich, 8093 Zuerich (Switzerland); Bretz, T. [Ecole Polytechnique Federale de Lausanne, 1015 Lausanne (Switzerland); Commichau, S.; Commichau, V.; Dorner, D.; Gendotti, A. [Eidgenoessische Technische Hochschule Zuerich, 8093 Zuerich (Switzerland); Grimm, O., E-mail: oliver.grimm@phys.ethz.c [Eidgenoessische Technische Hochschule Zuerich, 8093 Zuerich (Switzerland); Gunten, H. von; Hildebrand, D.; Horisberger, U. [Eidgenoessische Technische Hochschule Zuerich, 8093 Zuerich (Switzerland); Koehne, J.-H. [Technische Universitaet Dortmund, 44221 Dortmund (Germany); Kraehenbuehl, T.; Kranich, D.; Lorenz, E.; Lustermann, W. [Eidgenoessische Technische Hochschule Zuerich, 8093 Zuerich (Switzerland); Mannheim, K. [Universitaet Wuerzburg, 97074 Wuerzburg (Germany)

    2011-02-01

    Imaging Atmospheric Cherenkov Telescopes (IACT) for Gamma-ray astronomy are presently using photomultiplier tubes as photo sensors. Geiger-mode avalanche photodiodes (G-APD) promise an improvement in sensitivity and, important for this application, ease of construction, operation and ruggedness. G-APDs have proven many of their features in the laboratory, but a qualified assessment of their performance in an IACT camera is best undertaken with a prototype. This paper describes the design and construction of a full-scale camera based on G-APDs realized within the FACT project (First G-APD Cherenkov Telescope).

  4. Prototyping the graphical user interface for the operator of the Cherenkov Telescope Array

    CERN Document Server

    Sadeh, Iftach; Schwarz, Joseph; Pietriga, Emmanuel

    2016-01-01

    The Cherenkov Telescope Array (CTA) is a planned gamma-ray observatory. CTA will incorporate about 100 imaging atmospheric Cherenkov telescopes (IACTs) at a Southern site, and about 20 in the North. Previous IACT experiments have used up to five telescopes. Subsequently, the design of a graphical user interface (GUI) for the operator of CTA involves new challenges. We present a GUI prototype, the concept for which is being developed in collaboration with experts from the field of Human-Computer Interaction. The prototype is based on Web technology; it incorporates a Python web server, Web Sockets and graphics generated with the d3.js Javascript library.

  5. Prototyping the graphical user interface for the operator of the Cherenkov Telescope Array

    Science.gov (United States)

    Sadeh, I.; Oya, I.; Schwarz, J.; Pietriga, E.

    2016-07-01

    The Cherenkov Telescope Array (CTA) is a planned gamma-ray observatory. CTA will incorporate about 100 imaging atmospheric Cherenkov telescopes (IACTs) at a Southern site, and about 20 in the North. Previous IACT experiments have used up to five telescopes. Subsequently, the design of a graphical user interface (GUI) for the operator of CTA involves new challenges. We present a GUI prototype, the concept for which is being developed in collaboration with experts from the field of Human-Computer Interaction (HCI). The prototype is based on Web technology; it incorporates a Python web server, Web Sockets and graphics generated with the d3.js Javascript library.

  6. Combined complex Doppler and Cherenkov effect in left-handed metamaterials

    CERN Document Server

    Ziemkiewicz, David

    2015-01-01

    We derive the formula of the complex Doppler shift in a two-dimensional, dispersive metamaterial and we show that a moving, monochromatic radiation source generates multiple frequency modes. The role of the group velocity is stressed and the Doppler shifted radiation field exhibits features of the Cherenkov effect. The presented theory is also applicable to the case of a moving, nonoscillating charge and explains many peculiar characteristics of the Cherenkov radiation in lefthanded metamaterials such as the backward direction of power emission, the constant radiation angle and the lack of velocity threshold.

  7. Performance of the LHCb RICH detector at the LHC.

    Science.gov (United States)

    Adinolfi, M; Aglieri Rinella, G; Albrecht, E; Bellunato, T; Benson, S; Blake, T; Blanks, C; Brisbane, S; Brook, N H; Calvi, M; Cameron, B; Cardinale, R; Carson, L; Contu, A; Coombes, M; D'Ambrosio, C; Easo, S; Egede, U; Eisenhardt, S; Fanchini, E; Fitzpatrick, C; Fontanelli, F; Forty, R; Frei, C; Gandini, P; Gao, R; Garra Tico, J; Giachero, A; Gibson, V; Gotti, C; Gregson, S; Gys, T; Haines, S C; Hampson, T; Harnew, N; Hill, D; Hunt, P; John, M; Jones, C R; Johnson, D; Kanaya, N; Katvars, S; Kerzel, U; Kim, Y M; Koblitz, S; Kucharczyk, M; Lambert, D; Main, A; Maino, M; Malde, S; Mangiafave, N; Matteuzzi, C; Mini', G; Mollen, A; Morant, J; Mountain, R; Morris, J V; Muheim, F; Muresan, R; Nardulli, J; Owen, P; Papanestis, A; Patel, M; Patrick, G N; Perego, D L; Pessina, G; Petrolini, A; Piedigrossi, D; Plackett, R; Playfer, S; Powell, A; Rademacker, J H; Ricciardi, S; Rogers, G J; Sail, P; Sannino, M; Savidge, T; Sepp, I; Sigurdsson, S; Soler, F J P; Solomin, A; Soomro, F; Sparkes, A; Spradlin, P; Storaci, B; Thomas, C; Topp-Joergensen, S; Torr, N; Ullaland, O; Vervink, K; Voong, D; Websdale, D; Wilkinson, G; Wotton, S A; Wyllie, K; Xing, F; Young, R

    The LHCb experiment has been taking data at the Large Hadron Collider (LHC) at CERN since the end of 2009. One of its key detector components is the Ring-Imaging Cherenkov (RICH) system. This provides charged particle identification over a wide momentum range, from 2-100 GeV/c. The operation and control, software, and online monitoring of the RICH system are described. The particle identification performance is presented, as measured using data from the LHC. Excellent separation of hadronic particle types (π, K, p) is achieved.

  8. Performance of the LHCb RICH detector at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Adinolfi, M.; Brook, N.H.; Coombes, M.; Hampson, T.; Rademacker, J.H.; Solomin, A.; Voong, D. [University of Bristol, H.H. Wills Physics Laboratory, Bristol (United Kingdom); Aglieri Rinella, G.; Albrecht, E.; D' Ambrosio, C.; Forty, R.; Frei, C.; Gys, T.; Kanaya, N.; Koblitz, S.; Mollen, A.; Morant, J.; Piedigrossi, D.; Storaci, B.; Ullaland, O.; Vervink, K.; Wyllie, K. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Bellunato, T.; Calvi, M.; Fanchini, E.; Giachero, A.; Gotti, C.; Kucharczyk, M.; Maino, M.; Matteuzzi, C.; Perego, D.L.; Pessina, G. [Sezione INFN di Milano Bicocca, Milano (Italy); Benson, S.; Eisenhardt, S.; Fitzpatrick, C.; Kim, Y.M.; Lambert, D.; Main, A.; Muheim, F.; Playfer, S.; Sparkes, A.; Young, R. [University of Edinburgh, School of Physics and Astronomy, Edinburgh (United Kingdom); Blake, T. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Imperial College London, London (United Kingdom); Blanks, C.; Cameron, B.; Carson, L.; Egede, U.; Owen, P.; Patel, M.; Plackett, R.; Savidge, T.; Sepp, I.; Soomro, F.; Websdale, D. [Imperial College London, London (United Kingdom); Brisbane, S.; Contu, A.; Gandini, P.; Gao, R.; Harnew, N.; Hill, D.; Hunt, P.; John, M.; Johnson, D.; Malde, S.; Muresan, R.; Powell, A.; Thomas, C.; Topp-Joergensen, S.; Torr, N.; Wilkinson, G.; Xing, F. [University of Oxford, Department of Physics, Oxford (United Kingdom); Cardinale, R.; Fontanelli, F.; Mini' , G.; Petrolini, A.; Sannino, M. [Sezione INFN di Genova, Genova (Italy); Easo, S. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); STFC Rutherford Appleton Laboratory, Didcot (United Kingdom); Garra Tico, J.; Gibson, V.; Gregson, S.; Haines, S.C.; Jones, C.R.; Katvars, S.; Kerzel, U.; Mangiafave, N.; Rogers, G.J.; Sigurdsson, S.; Wotton, S.A. [University of Cambridge, Cavendish Laboratory, Cambridge (United Kingdom); Mountain, R. [Syracuse University, Syracuse, NY (United States); Morris, J.V.; Nardulli, J.; Papanestis, A.; Patrick, G.N.; Ricciardi, S. [STFC Rutherford Appleton Laboratory, Didcot (United Kingdom); Sail, P.; Soler, F.J.P.; Spradlin, P. [University of Glasgow, School of Physics and Astronomy, Glasgow (United Kingdom); Collaboration: The LHCb RICH Collaboration

    2013-05-15

    The LHCb experiment has been taking data at the Large Hadron Collider (LHC) at CERN since the end of 2009. One of its key detector components is the Ring-Imaging Cherenkov (RICH) system. This provides charged particle identification over a wide momentum range, from 2-100 GeV/c. The operation and control, software, and online monitoring of the RICH system are described. The particle identification performance is presented, as measured using data from the LHC. Excellent separation of hadronic particle types ({pi}, K, p) is achieved. (orig.)

  9. IceCube: A Cubic Kilometer Radiation Detector

    Energy Technology Data Exchange (ETDEWEB)

    IceCube Collaboration; Klein, Spencer R; Klein, S.R.

    2008-06-01

    IceCube is a 1 km{sup 3} neutrino detector now being built at the Amudsen-Scott South Pole Station. It consists of 4800 Digital Optical Modules (DOMs) which detect Cherenkov radiation from the charged particles produced in neutrino interactions. IceCube will observe astrophysical neutrinos with energies above about 100 GeV. IceCube will be able to separate {nu}{sub {mu}}, {nu}{sub t}, and {nu}{sub {tau}} interactions because of their different topologies. IceCube construction is currently 50% complete.

  10. Construction of a Medium-Sized Schwarzschild-Couder Telescope for the Cherenkov Telescope Array: Implementation of the Cherenkov-Camera Data Acquisition System

    CERN Document Server

    Santander, M; Humensky, B; Mukherjee, R

    2015-01-01

    A medium-sized Schwarzchild-Couder Telescope (SCT) is being developed as a possible extension for the Cherenkov Telescope Array (CTA). The Cherenkov camera of the telescope is designed to have 11328 silicon photomultiplier pixels capable of capturing high-resolution images of air showers in the atmosphere. The combination of the large number of pixels and the high trigger rate (> 5 kHz) expected for this telescope results in a multi-Gbps data throughput. This sets challenging requirements on the design and performance of a data acquisition system for processing and storing this data. A prototype SCT (pSCT) with a partial camera containing 1600 pixels, covering a field of view of 2.5 x 2.5 square degrees, is being assembled at the F.L. Whipple Observatory. We present the design and current status of the SCT data acquisition system.

  11. The Cherenkov Telescope Array Observatory: top level use cases

    Science.gov (United States)

    Bulgarelli, A.; Kosack, K.; Hinton, J.; Tosti, G.; Schwanke, U.; Schwarz, J.; Colomé, P.; Conforti, V.; Khelifi, B.; Goullon, J.; Ong, R.; Markoff, S.; Contreras, J. L.; Lucarelli, F.; Antonelli, L. A.; Bigongiari, C.; Boisson, C.; Bosnjak, Z.; Brau-Nogué, S.; Carosi, A.; Chen, A.; Cotter, G.; Covino, S.; Daniel, M.; De Cesare, G.; de Ona Wilhelmi, E.; Della Volpe, M.; Di Pierro, F.; Fioretti, V.; Füßling, M.; Garczarczyk, M.; Gaug, M.; Glicenstein, J. F.; Goldoni, P.; Götz, D.; Grandi, P.; Heller, M.; Hermann, G.; Inoue, S.; Knödlseder, J.; Lenain, J.-P.; Lindfors, E.; Lombardi, S.; Luque-Escamilla, P.; Maier, G.; Marisaldi, M.; Mundell, C.; Neyroud, N.; Noda, K.; O'Brien, P.; Petrucci, P. O.; Martí Ribas, J.; Ribó, M.; Rodriguez, J.; Romano, P.; Schmid, J.; Serre, N.; Sol, H.; Schussler, F.; Stamerra, A.; Stolarczyk, T.; Vandenbrouck, J.; Vercellone, S.; Vergani, S.; Zech, A.; Zoli, A.

    2016-08-01

    Today the scientific community is facing an increasing complexity of the scientific projects, from both a technological and a management point of view. The reason for this is in the advance of science itself, where new experiments with unprecedented levels of accuracy, precision and coverage (time and spatial) are realised. Astronomy is one of the fields of the physical sciences where a strong interaction between the scientists, the instrument and software developers is necessary to achieve the goals of any Big Science Project. The Cherenkov Telescope Array (CTA) will be the largest ground-based very high-energy gamma-ray observatory of the next decades. To achieve the full potential of the CTA Observatory, the system must be put into place to enable users to operate the telescopes productively. The software will cover all stages of the CTA system, from the preparation of the observing proposals to the final data reduction, and must also fit into the overall system. Scientists, engineers, operators and others will use the system to operate the Observatory, hence they should be involved in the design process from the beginning. We have organised a workgroup and a workflow for the definition of the CTA Top Level Use Cases in the context of the Requirement Management activities of the CTA Observatory. Scientists, instrument and software developers are collaborating and sharing information to provide a common and general understanding of the Observatory from a functional point of view. Scientists that will use the CTA Observatory will provide mainly Science Driven Use Cases, whereas software engineers will subsequently provide more detailed Use Cases, comments and feedbacks. The main purposes are to define observing modes and strategies, and to provide a framework for the flow down of the Use Cases and requirements to check missing requirements and the already developed Use-Case models at CTA sub-system level. Use Cases will also provide the basis for the definition of

  12. The New ATLAS/LUCID detector

    CERN Document Server

    Bruschi, Marco; The ATLAS collaboration

    2015-01-01

    The new ATLAS luminosity monitor has many innovative aspects implemented. Its photomultipliers tubes are used as detector elements by using the Cherenkov light produced by charged particles above threshold crossing the quartz windows. The analog shaping of the readout chain has been improved, in order to cope with the 25 ns bunch spacing of the LHC machine. The main readout card is a quite general processing unit based on 12 bit - 500 MS/s Flash ADC and on FPGAs, delivering the processed data to 1.3 Gb/s optical links. The talk will describe all these aspects and will outline future perspectives of the card for next generation high energy physics experiments.

  13. The new ATLAS/LUCID detector

    CERN Document Server

    Bruschi, Marco; The ATLAS collaboration

    2015-01-01

    The new ATLAS luminosity monitor has many innovative aspects implemented. Its photomultipliers tubes are used as detector elements by using the Cherenkov light produced by charged particles above threshold crossing the quartz windows. The analog shaping of the readout chain has been improved, in order to cope with the 25 ns bunch spacing of the LHC machine. The main readout card is a quite general processing unit based on 12 bit - 320 MS/s Flash ADC and on FPGAs, delivering the processed data to 1.3 Gb/s optical links. The article will describe all these aspects and will outline future perspectives of the card for next generation high energy physics experiments.

  14. Academic Training: Particle Detectors - Principles and Techniques

    CERN Multimedia

    Françoise Benz

    2005-01-01

    2004-2005 ACADEMIC TRAINING PROGRAMME LECTURE SERIES FOR POSTGRADUATE STUDENTS 11, 12, 13, 14 & 15 April from 11.00 to 12.00 hrs - Main Auditorium, bldg. 500 Particle Detectors - Principles and Techniques C. JORAM, L. ROPELEWSKI, M. MOLL, C. D'AMBROSIO, T. GYS / CERN-PH The lecture series presents an overview of the physical principles and basic techniques of particle detection, applied to current and future high energy physics experiments. Illustrating examples, chosen mainly from the field of collider experiments, demonstrate the performance and limitations of the various techniques. Main topics of the series are: interaction of particles and photons with matter; particle tracking with gaseous and solid state devices, including a discussion of radiation damage and strategies for improved radiation hardness; scintillation and photon detection; electromagnetic and hadronic calorimetry; particle identification using specific energy loss dE/dx, time of flight, Cherenkov light and transition radi...

  15. The new ATLAS/LUCID detector

    Energy Technology Data Exchange (ETDEWEB)

    Bruschi, Marco [INFN, Bologna, (Italy)

    2015-07-01

    The new ATLAS luminosity monitor has many innovative aspects implemented. Its photomultipliers tubes are used as detector elements by using the Cherenkov light produced by charged particles above threshold crossing the quartz windows. The analog shaping of the readout chain has been improved, in order to cope with the 25 ns bunch spacing of the LHC machine. The main readout card is a quite general processing unit based on 12 bit - 500 MS/s Flash ADC and on FPGAs, delivering the processed data to 1.3 Gb/s optical links. The article will describe all these aspects and will outline future perspectives of the card for next generation high energy physics experiments. (authors)

  16. Real-time pattern recognition for the electron detection with a RICH detector in relativistic heavy ion collisions

    CERN Document Server

    Lehnert, J

    2001-01-01

    detector simulations as well as from test experiments of the real detector and thereby from the simulated data a ring-recognition efficiency above 90% at less than 0. 5 misidentified electrons/event for an optimized detector determined. In the present thesis a fast real-time trigger system for the identification of dileptons in a given invariant-mass interval is described as well as especially the trigger component for the recognition of electron and positron signatures on the segmented detector area of a ring-imaging Cherenkov detector presented. This comprehends the complete development of the hardware as well a fitted algorithm for the ring recognition. A component of this system are the trigger electronics for the processing of data of a hadron-blind ring- imaging Cherenkov detector. The electronics consist of two VME plug-in cards per detector segment, which reconstruct from the coordinate informations of the detector read-out within in the meam 40 mu s the complete hit pattern, perform on the base of th...

  17. Design of a 7m Davies-Cotton Cherenkov telescope mount for the high energy section of the Cherenkov Telescope Array

    CERN Document Server

    Rovero, A C; Vallejo, G; Supanitsky, A D; Actis, M; Botani, A; Ochoa, I; Hughes, G

    2013-01-01

    The Cherenkov Telescope Array is the next generation ground-based observatory for the study of very-high-energy gamma-rays. It will provide an order of magnitude more sensitivity and greater angular resolution than present systems as well as an increased energy range (20 GeV to 300 TeV). For the high energy portion of this range, a relatively large area has to be covered by the array. For this, the construction of ~7 m diameter Cherenkov telescopes is an option under study. We have proposed an innovative design of a Davies-Cotton mount for such a telescope, within Cherenkov Telescope Array specifications, and evaluated its mechanical and optical performance. The mount is a reticulated-type structure with steel tubes and tensioned wires, designed in three main parts to be assembled on site. In this work we show the structural characteristics of the mount and the optical aberrations at the focal plane for three options of mirror facet size caused by mount deformations due to wind and gravity.

  18. Desarrollo de un detector de rayos cósmicos de la colaboración LAGO en Buenos Aires - Aplicaciones en meteorología espacial

    Science.gov (United States)

    Coppola, M.; Bezzecchi, F.; Gulisano, A. M.; Masías-Meza, J. J.; Areso, O.; Ramelli, M.; Dasso, S.; LAGO Collaboration

    2016-08-01

    The study of low energy cosmic particles allows to analyze several aspects of major interest for space weather. Ground detectors permit to observe secundary particles produced during the cascades developed in the atmosphere. The characterization of a prototype for a water Cherenkov radiation particles detector, in the frame of the LAGO collaboration (Latin American Giant Observatory), is presented in this work. The collaboration plans to install this detector at the LAGO antarctic site. The developed acquisition system and the method used to make the energy callibration of the detector are detailed here, as also corrections for atmospheric effects.

  19. Cherenkov light detection as a velocity selector for uranium fission products at intermediate energies

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, T., E-mail: yamaguti@phy.saitama-u.ac.jp [Department of Physics, Saitama University, Saitama 338-8570 (Japan); Enomoto, A.; Kouno, J.; Yamaki, S.; Matsunaga, S.; Suzaki, F.; Suzuki, T. [Department of Physics, Saitama University, Saitama 338-8570 (Japan); Abe, Y.; Nagae, D.; Okada, S.; Ozawa, A.; Saito, Y.; Sawahata, K. [Institute of Physics, University of Tsukuba, Ibaraki 305-8571 (Japan); Kitagawa, A.; Sato, S. [National Institute of Radiological Sciences, Chiba 263-8555 (Japan)

    2014-12-01

    The in-flight particle separation capability of intermediate-energy radioactive ion (RI) beams produced at a fragment separator can be improved with the Cherenkov light detection technique. The cone angle of Cherenkov light emission varies as a function of beam velocity. This can be exploited as a velocity selector for secondary beams. Using heavy ion beams available at the HIMAC synchrotron facility, the Cherenkov light angular distribution was measured for several thin radiators with high refractive indices (n=1.9∼2.1). A velocity resolution of ∼10{sup −3} was achieved for a {sup 56}Fe beam with an energy of 500 MeV/nucleon. Combined with the conventional rigidity selection technique coupled with energy-loss analysis, the present method will enable the efficient selection of an exotic species from huge amounts of various nuclides, such as uranium fission products at the BigRIPS fragment separator located at the RI Beam Factory. - Highlights: • The cone angle of Cherenkov light can be used as a velocity selector of RI beams. • Proof-of-principle experiments are made using heavy ions at intermediate energies. • Results demonstrate successful separation of RI beams produced by fragmentation. • A velocity resolution of 10{sup −3} is achieved for thin high refractive radiators.

  20. Cherenkov-type diagnostics of fast electrons beams escaping from MCF facilities

    Energy Technology Data Exchange (ETDEWEB)

    Jakubowski, L.; Malinowski, K.; Mirowski, R.; Rabinski, M.; Sadowski, M.J.; Zebrowski, J. [Institute for Nuclear Studies - IPJ, 05-400 Otwock-Swierk (Poland)

    2011-07-01

    The paper presents the feasibility study, the measuring system and the first experimental results of a new method developed for direct detection of high-energy (super-thermal, ripple-born and runaway) electrons generated in magnetic confinement fusion (MCF) facilities. The technique in question is based on registration of the Cherenkov radiation, emitted by energetic electrons, moving through a transparent medium (radiator) with a velocity higher than the velocity of light in this material. The main aim of our studies was to develop a diagnostic technique applicable for measurements of fast electron beams within MCF devices. The IPJ team proposed Cherenkov-type probes because of their high spatial- and temporal-resolutions. The most important results of applications of the presented Cherenkov-type diagnostics have proved that the one- and four-channel versions of the detecting head are useful for studies of the fast (ripple-born and runaway) electrons in different MCF experiments. Experience collected during the described studies allows to introduce some changes in the radiator configuration and to modify the Cherenkov probe design. This document is composed of a paper followed by a poster

  1. Low-Noise Operation of All-Fiber Femtosecond Cherenkov Laser

    DEFF Research Database (Denmark)

    Liu, Xiaomin; Villanueva Ibáñez, Guillermo Eduardo; Lægsgaard, Jesper;

    2013-01-01

    We investigate the noise properties of a femtosecond all-fiber Cherenkov radiation source with emission wavelength around 600 nm, based on an Yb-fiber laser and a highly-nonlinear photonic crystal fiber. A relative intensity noise as low as - 103 dBc/Hz, corresponding to 2.48 % pulse-to-pulse flu...

  2. The Potential of Spaced-based High-Energy Neutrino Measurements via the Airshower Cherenkov Signal

    CERN Document Server

    Krizmanic, John F

    2011-01-01

    Future space-based experiments, such as OWL and JEM-EUSO, view large atmospheric and terrestrial neutrino targets. With energy thresholds slightly above 10^19 eV for observing airshowers via air fluorescence, the potential for observing the cosmogenic neutrino flux associated with the GZK effect is limited. However, the forward Cherenkov signal associated with the airshower can be observed at much lower energies. A simulation was developed to determine the Cherenkov signal strength and spatial extent at low-Earth orbit for upward-moving airshowers. A model of tau neutrino interactions in the Earth was employed to determine the event rate of interactions that yielded a tau lepton which would induce an upward-moving airshower observable by a space-based instrument. The effect of neutrino attenuation by the Earth forces the viewing of the Earth's limb to observe the nu_tau-induced Cherenkov airshower signal at above the OWL Cherenkov energy threshold of ~10^16.5 eV for limb-viewed events. Furthermore, the neutri...

  3. Search for relativistic magnetic monopoles with the AMANDA-II detector

    Energy Technology Data Exchange (ETDEWEB)

    Wissing, Henrike

    2009-02-25

    Cherenkov emissions of magnetically charged particles passing through a transparent medium will exceed those of electrically charged particles by several orders of magnitude. The Antarctic Muon And Neutrino Detector Array (AMANDA), a neutrino telescope utilizing the glacial ice at the geographic South Pole as Cherenkov medium, is capable of efficiently detecting relativistic magnetic monopoles that may pass through its sensitive volume. This thesis presents the search for Cherenkov signatures from relativistic magnetic monopoles in data taken with AMANDA during the 2000. No such signal is observed in the data, and the analysis allows to place upper limits on the flux of relativistic magnetic monopoles. The limit obtained for monopoles reaching the detector from below the horizon, i.e., those monopoles that are capable of crossing the Earth, is the most stringent experimental constraint on the flux of magnetic monopoles to date: Dependent on the monopole speed, the flux limit (at 90% confidence level) varies between 3.8 x 10{sup -17} cm{sup -2}s{sup -1}sr{sup -1} (for monopoles moving at the vacuum speed of light) and 8.8 x 10{sup -16} cm{sup -2}s{sup -1}sr{sup -1} (for monopoles moving at a speed just above the Cherenkov threshold). The limit obtained for monopoles reaching the detector from above the horizon is less stringent by roughly an order of magnitude, owing to the much larger background from down-going atmospheric muons. This looser limit is valid for a larger class of magnetic monopoles, since the monopole's capability to pass through the Earth is not a requirement. (orig.)

  4. Design and performance of a lead fluoride detector as a luminosity monitor

    Energy Technology Data Exchange (ETDEWEB)

    Pérez Benito, R.; Khaneft, D. [Johannes Gutenberg-Universität, Mainz (Germany); O' Connor, C., E-mail: colton@mit.edu [Massachusetts Institute of Technology, Cambridge, MA (United States); Capozza, L. [Johannes Gutenberg-Universität, Mainz (Germany); Diefenbach, J. [Hampton University, Hampton, VA (United States); Gläser, B.; Ma, Y.; Maas, F.E.; Rodríguez Piñeiro, D. [Johannes Gutenberg-Universität, Mainz (Germany)

    2016-08-01

    Precise luminosity measurements for the OLYMPUS two-photon exchange experiment at DESY were performed by counting scattering events with alternating beams of electrons and positrons incident on atomic electrons in a gaseous hydrogen target. Final products of Møller, Bhabha, and pair annihilation interactions were observed using a pair of lead fluoride Cherenkov calorimeters with custom housings and electronics, adapted from a system used by the A4 parity violation experiment at MAMI. This paper describes the design, calibration, and operation of these detectors. An explanation of the Monte Carlo methods used to simulate the physical processes involved both at the scattering vertices and in the detector apparatus is also included.

  5. Performance of the CAPRICE RICH detector during the 1994 balloon flight

    Energy Technology Data Exchange (ETDEWEB)

    Barbiellini, G.; Basini, G.; Bellotti, R.; Bocciolini, M.; Boezio, M.; Massimo Brancaccio, F.; Bravar, U.; Cafagna, F.; Candusso, M.; Carlson, P.; Casolino, M.; Castellano, M.; De Cataldo, G.; Circella, M.; Codino, A.; Finetti, N.; Francke, T.; Giglietto, N.; Golden, R.L.; Grimani, C.; Hof, M.; Marangelli, B.; De Marzo, C.N.; Mitchell, J.W.; Morselli, A.; De Pascale, M.P.; Papini, P.; Perego, A.; Piccardi, S.; Picozza, P.; Ricci, M.; Schiavon, P.; Simon, M.; Sparvoli, R.; Spillantini, P.; Spinelli, P.; Stephens, S.A.; Stochaj, S.J.; Streitmatter, R.E.; Suffert, M.; Vacchi, A.; Weber, N.; Zampa, N. [Particle Astrophysics Lab, New Mexico State Univ., Las Cruces, NM (United States)]|[Tata Institute of fundamental Research, Bombay (India)]|[Goddard Space Flight Center/NASA, Greenbelt, MD (United States)]|[Royal Institute of Technology, Stockholm (Sweden)]|[Centre de Recherches Nucleaires, Strasbourg (France)]|[Dipartimento di Fisica dell`Univ. di Perugia and INFN-Sezione di Perugia, Perugia (Italy)]|[INFN Laboratori Nazionali di Frascati, Frascati (Italy)]|[Dipartimento di Fisica dell`Univ. di Firenze and INFN-Sezione di Firenze, Florence (Italy)]|[Dipartimento di Fisica dell`Univ. di Roma II ``Tor Vergata`` and INFN-Sezione di Roma II ``Tor Vergata``, Roma (Italy)]|[Dipartimento di Fisica dell`Univ. di Trieste and INFN-Sezione di Trieste, Trieste (Italy)]|[Dipartimento di Fisica dell`Univ. di Bari and INFN-Sezione di Bari, Trieste (Italy)]|[University of Siegen, Siegen (Germany)

    1996-03-01

    A RICH detector capable of detecting unit charged particles, e.g. antiprotons and positrons, has been used successfully for the first time in a balloon-borne magnet spectrometer. The thin and compact CAPRICE RICH detector uses a NaF solid radiator, TMAE vapour as photoconverter and cathode pad readout in the photosensitive MWPC operated at low gain. 15 photoelectrons are detected per ring for {beta}=1, perpendicular incidence particles giving a resolution on the Cherenkov angle of 8 mrad, increasing to 14 mrad at 20 incidence angle. Besides particle identification on an event-by-event basis it efficiently rejects multiparticle events and albedo particles. (orig.).

  6. The laser calibration system for the STACEE ground-based gamma ray detector

    CERN Document Server

    Hanna, D

    2002-01-01

    We describe the design and performance of the laser system used for calibration monitoring of components of the STACEE detector. STACEE is a ground based gamma ray detector which uses the heliostats of a solar power facility to collect and focus Cherenkov light onto a system of secondary optics and photomultiplier tubes. To monitor the gain and check the linearity and timing properties of the phototubes and associated electronics, a system based on a dye laser, neutral density filters and optical fibres has been developed. In this paper we describe the system and present some results from initial tests made with it.

  7. Cleaning and recirculation of perfluorohexane ($C_{6} F_{14}$) in the STAR-RICH detector

    CERN Document Server

    Andrés, Yu; Cozza, D; Davenport, M; De Cataldo, G; Dell'Olio, L; Di Bari, D; Di Mauro, A; Dunlop, J C; Finch, E; Fraissard, Daniel; Franco, A; Gans, J; Ghidini, B; Harris, J W; Horsley, M; Kunde, G J; Lasiuk, B; Lesenechal, Y; Majka, R D; Martinengo, P; Morsch, Andreas; Nappi, E; Paic, G; Piuz, François; Posa, F; Raynaud, J; Salur, S; Sandweiss, J; Santiard, Jean-Claude; Satinover, J; Schyns, E M; Smirnov, N; Van Beelen, J; Williams, T D; Xu, Z

    2002-01-01

    A RICH detector with a CsI photo-cathode and liquid perfluorohexane radiator has been installed in the STAR experiment at RHIC. The liquid is continuously cleaned and distributed to a quartz containment vessel within the detector by a closed recirculation system. A VUV spectrometer is connected to the system which monitors the optical transparency of the liquid. This measurement provides one of the pieces of information necessary to model the number of Cherenkov photons which reach the pad plane. A description of the liquid recirculation system and the cleaning procedure for the liquid as well as the spectrometer is presented along with results of their performance. (23 refs).

  8. Pixel detectors

    CERN Document Server

    Passmore, M S

    2001-01-01

    positions on the detector. The loss of secondary electrons follows the profile of the detector and increases with higher energy ions. studies of the spatial resolution predict a value of 5.3 lp/mm. The image noise in photon counting systems is investigated theoretically and experimentally and is shown to be given by Poisson statistics. The rate capability of the LAD1 was measured to be 250 kHz per pixel. Theoretical and experimental studies of the difference in contrast for ideal charge integrating and photon counting imaging systems were carried out. It is shown that the contrast differs and that for the conventional definition (contrast = (background - signal)/background) the photon counting device will, in some cases, always give a better contrast than the integrating system. Simulations in MEDICI are combined with analytical calculations to investigate charge collection efficiencies (CCE) in semiconductor detectors. Different pixel sizes and biasing conditions are considered. The results show charge shari...

  9. Calorimeter detectors

    CERN Document Server

    de Barbaro, P; The ATLAS collaboration

    2013-01-01

    Although the instantaneous and integrated luminosity in HL-LHC will be far higher than the LHC detectors were originally designed for, the Barrel calorimeters of the four experiments are expected to continue to perform well  throughout the Phase II program. The conditions for the End-Cap calorimeters are far more challenging and whilst some detectors will require relatively modest changes, others require far more substantial upgrades. We present the results of longevity and performance studies for the calorimeter systems of the four main LHC experiments and outline the upgrade options under consideration. We include a discussion of the R&D required to make the final technology choices for the upgraded detectors.

  10. The CMS Beam Halo Monitor Detector System

    CERN Document Server

    Stifter, Kelly Marie

    2015-01-01

    A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of collimators before the CMS experiment and from beam gas interactions. The BHM detector uses the directional nature of Cherenkov radiation and event timing to select particles coming from the direction of the beam and to supress those originating from the interaction point. It consists of 40 quartz rods, placed on each side of the CMS detector, coupled to UV sensitive PMTs. For each bunch crossing the PMT signal is digitized by a charge integrating ASIC and the arrival time of the signal is recorded. The data are processed in real time to yield a precise measurement of per-bunch-crossing background rate. This measurement is made available to CMS and the LHC, to provide real-time feedback on the beam quality and to improve the efficiency of data taking. In this talk we will descri...

  11. The CMS Beam Halo Monitor Detector System

    CERN Document Server

    CMS Collaboration

    2015-01-01

    A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of collimators before the CMS experiment and from beam gas interactions. The BHM detector uses the directional nature of Cherenkov radiation and event timing to select particles coming from the direction of the beam and to suppress those originating from the interaction point. It consists of 40 quartz rods, placed on each side of the CMS detector, coupled to UV sensitive PMTs. For each bunch crossing the PMT signal is digitized by a charge integrating ASIC and the arrival time of the signal is recorded. The data are processed in real time to yield a precise measurement of per-bunch-crossing background rate. This measurement is made available to CMS and the LHC, to provide real-time feedback on the beam quality and to improve the efficiency of data taking. In this talk we will describ...

  12. Scintillation Detector for the Measurement of Ultra-Heavy Cosmic Rays on the Super-TIGER Experiment

    Science.gov (United States)

    Link, Jason

    2011-01-01

    We discuss the design and construction of the scintillation detectors for the Super-TIGER experiment. Super-TIGER is a large-area (5.4sq m) balloon-borne experiment designed to measure the abundances of cosmic-ray nuclei between Z= 10 and Z=56. It is based on the successful TIGER experiment that flew in Antarctica in 2001 and 2003. Super-TIGER has three layers of scintillation detectors, two Cherenkov detectors and a scintillating fiber hodoscope. The scintillation detector employs four wavelength shifter bars surrounding the edges of the scintillator to collect the light from particles traversing the detector. PMTs are optically coupled at both ends of the bars for light collection. We report on laboratory performance of the scintillation counters using muons. In addition we discuss the design challenges and detector response over this broad charge range including the effect of scintilator saturation.

  13. Hybrid Extensive Air Shower Detector Array at the University of Puebla to Study Cosmic Rays

    Science.gov (United States)

    Martínez, O.; Pérez, E.; Salazar, H.; Villaseñor, L.

    We describe the design of an extensive air shower detector array built in the Campus of the University of Puebla (located at 19°N, 90°W, 800 gcm -2) to measure the energy and arrival direction of primary cosmic rays with energies around 1015 eV. The array consists of 18 liquid scintillator detectors (12 in the first stage) and 6 water Cherenkov detectors (one of 10 m 2 cross section and five smaller ones of 1.86 m 2 cross section), distributed in a square grid with a detector spacing of 20 m over an area of 4000 m 2. In this paper we discuss the calibration and stability of the array, and discuss the capability of hybrid arrays, such as this one consisting of water Cherenkov and liquid scintillator detectors, to allow a separation of the electromagnetic and muon components of extensive air showers. This separation plays an important role in the determination of the mass and identity of the primary cosmic ray. This facility is also used to train students interested in the field of cosmic rays.

  14. XMASS detector

    Energy Technology Data Exchange (ETDEWEB)

    Abe, K. [Kamioka Observatory, Institute for Cosmic Ray Research, The University of Tokyo, Higashi-Mozumi, Kamioka, Hida, Gifu 506-1205 (Japan); Kavli Institute for the Physics and Mathematics of the Universe, the University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Hieda, K. [Kamioka Observatory, Institute for Cosmic Ray Research, The University of Tokyo, Higashi-Mozumi, Kamioka, Hida, Gifu 506-1205 (Japan); Hiraide, K. [Kamioka Observatory, Institute for Cosmic Ray Research, The University of Tokyo, Higashi-Mozumi, Kamioka, Hida, Gifu 506-1205 (Japan); Kavli Institute for the Physics and Mathematics of the Universe, the University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Hirano, S. [Kamioka Observatory, Institute for Cosmic Ray Research, The University of Tokyo, Higashi-Mozumi, Kamioka, Hida, Gifu 506-1205 (Japan); Kishimoto, Y.; Kobayashi, K.; Moriyama, S. [Kamioka Observatory, Institute for Cosmic Ray Research, The University of Tokyo, Higashi-Mozumi, Kamioka, Hida, Gifu 506-1205 (Japan); Kavli Institute for the Physics and Mathematics of the Universe, the University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Nakagawa, K. [Kamioka Observatory, Institute for Cosmic Ray Research, The University of Tokyo, Higashi-Mozumi, Kamioka, Hida, Gifu 506-1205 (Japan); Nakahata, M. [Kamioka Observatory, Institute for Cosmic Ray Research, The University of Tokyo, Higashi-Mozumi, Kamioka, Hida, Gifu 506-1205 (Japan); Kavli Institute for the Physics and Mathematics of the Universe, the University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Nishiie, H. [Kamioka Observatory, Institute for Cosmic Ray Research, The University of Tokyo, Higashi-Mozumi, Kamioka, Hida, Gifu 506-1205 (Japan); Ogawa, H. [Kamioka Observatory, Institute for Cosmic Ray Research, The University of Tokyo, Higashi-Mozumi, Kamioka, Hida, Gifu 506-1205 (Japan); Kavli Institute for the Physics and Mathematics of the Universe, the University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); and others

    2013-07-11

    The XMASS project aims to detect dark matter, pp and {sup 7}Be solar neutrinos, and neutrinoless double beta decay using ultra pure liquid xenon. The first phase of the XMASS experiment searches for dark matter. In this paper, we describe the XMASS detector in detail, including its configuration, data acquisition equipment and calibration system.

  15. XMASS detector

    CERN Document Server

    Abe, K; Hiraide, K; Hirano, S; Kishimoto, Y; Kobayashi, K; Moriyama, S; Nakagawa, K; Nakahata, M; Nishiie, H; Ogawa, H; Oka, N; Sekiya, H; Shinozaki, A; Suzuki, Y; Takeda, A; Takachio, O; Ueshima, K; Umemoto, D; Yamashita, M; Yang, B S; Tasaka, S; Liu, J; Martens, K; Hosokawa, K; Miuchi, K; Murata, A; Onishi, Y; Otsuka, Y; Takeuchi, Y; Kim, Y H; Lee, K B; Lee, M K; Lee, J S; Fukuda, Y; Itow, Y; Nishitani, Y; Masuda, K; Takiya, H; Uchida, H; Kim, N Y; Kim, Y D; Kusaba, F; Motoki, D; Nishijima, K; Fujii, K; Murayama, I; Nakamura, S

    2013-01-01

    The XMASS project aims to detect dark matter, pp and $^{7}$Be solar neutrinos, and neutrinoless double beta decay using ultra pure liquid xenon. The first phase of the XMASS experiment searches for dark matter. In this paper, we describe the XMASS detector in detail, including its configuration, data acquisition equipment and calibration system.

  16. An Overview of the Status of the LHCb RICH Detectors

    CERN Document Server

    Harnew, Neville

    2008-01-01

    The LHCb experiment will make precision measurements of CP violation and rare b-hadron decays. Efficient particle identification with high purity over a wide momentum range is vital to these aims. The experiment employs two ring-imaging Cherenkov (RICH) detectors with three radiators, silica aerogel, C$_4$F$_{10}$ and CF$_4$, to cover the momentum range from around 1 to 100 GeV/$c$. The RICH system employs a number of innovative techniques, both in hardware and software. A total of 484 custom-built pixel Hybrid Photon Detectors (HPDs) will be used to measure the spatial positions of Cherenkov photons with wavelengths in the range 200 to 600 nm, covering an active area of around 3.3 m$^2$. The production of the HPDs has now been completed and the tube quality, including the photo-cathode quantum efficiency, far exceeds expectations. The installation of RICH1 is almost complete; RICH2 has been installed and aligned, and commissioning is almost complete. Reconstruction studies incorporating realistic backgrounds...

  17. SU-E-CAMPUS-T-04: Measurement of Proton Pencil Beam Spot Profile Using Cherenkov Radiation in Two Dimensional Optical Fiber Arrays

    Energy Technology Data Exchange (ETDEWEB)

    Kim, M; SHIN, D; Park, J; Lim, Y; Lee, S; Kim, J [National Cancer Center, Goyang, Gyeonggi-do (Korea, Republic of); Son, J [National Cancer Center, Goyang, Gyeonggi-do, Korea University, Seoul, Gyeonggi-do (Korea, Republic of); Hwang, U [National Medical Center in Korea, Seoul (Korea, Republic of)

    2014-06-15

    Purpose: Proton therapy aims to deliver a high dose in a well-defined target volume while sparing the healthy surrounding tissues thanks to their inherent depth dose characteristic (Bragg peak). In proton therapy, several techniques can be used to deliver the dose into the target volume. The one that allows the best conformity with the tumor, is called PBS (Pencil Beam Scanning). The measurement of the proton pencil beam spot profile (spot size) and position is very important for the accurate delivery of dose to the target volume with a good conformity. Methods: We have developed a fine segmented detector array to monitor the PBS. A prototype beam monitor using Cherenkov radiation in clear plastic optical fibers (cPOF) has been developed for continuous display of the pencil beam status during the therapeutic proton Pencil Beam Scanning mode operation. The benefit of using Cherenkov radiation is that the optical output is linear to the dose. Pedestal substraction and the gain adjustment between channels are performed. Spot profiles of various pencil beam energies(100 MeV to 226 MeV) are measured. Two dimensional gaussian fit is used to analyze the beam width and the spot center. The results are compared with that of Lynx(Scintillator-based sensor with CCD camera) and EBT3 Film. Results: The measured gaussian widths using fiber array system changes from 13 to 5 mm for the beam energies from 100 to 226 MeV. The results agree well with Lynx and Film within the systematic error. Conclusion: The results demonstrate good monitoring capability of the system. Not only measuing the spot profile but also monitoring dose map by accumulating each spot measurement is available. The x-y monitoing system with 128 channel readout will be mounted to the snout for the in-situ real time monitoring.

  18. Measurement of the atmospheric muon flux with the ANTARES detector

    CERN Document Server

    Bazzotti, Marco

    2009-01-01

    ANTARES is a submarine neutrino telescope deployed in the Mediterranean Sea, at a depth of about 2500 m. It consists of a three-dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. Down-going muons produced in atmospheric showers are a physical background to the neutrino detection, and are being studied. In this paper the measurement of the Depth Intensity Relation (DIR) of atmospheric muon flux is presented. The data collected in June and July 2007, when the ANTARES detector was in its 5-line configuration, are used in the analysis. The corresponding livetime is $724 h$. A deconvolution method based on a Bayesian approach was developed, which takes into account detector and reconstruction inefficiencies. Comparison with other experimental results and Monte Carlo expectations are presented and discussed.

  19. Rich detector with a sodium fluoride radiator: /K identification up to 3 GeV/c

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, R.; Guyonnet, J.L.; Giomataris, Y.; Petroff, P.; Seguinot, J.; Tocqueville, J.; Ypsilantis, T.

    1988-12-15

    The use of a single crystal of sodium fluoride (NaF) as a Cherenkov radiator has been investigated. Its transparency has been measured and found to be good for photon energies below 9.6 eV. Data on its index of refraction are well fitted to a single-pole Sellmeier resonance formula. These data allow a realistic Monte Carlo simulation of a proximity-focused ring imaging Cherenkov (RICH) system. The photon detector is a multiwire proportional chamber (MWPC) with pad readout. The photosensitive gases considered are tetrakis(dimethylamine)ethylene (TMAE) and triethylamine (TEA). The simulation shows that a system having 10 cm radial thickness and 12% of a radiation length of material would identify pions and kaons below 3 GeV/c momentum. The pad dimensions required are about 5 mm x 5 mm.

  20. Testing micro-channel plate detectors for the particle identification upgrade of LHCb

    CERN Document Server

    Castillo Garcia, L

    2012-01-01

    The TORCH, Time of internally Reflected Cherenkov Light, is proposed for the high luminosity upgrade of the LHCb experiment. The detector combines Time-of-Flight and Cherenkov techniques to achieve positive pi/K/p separation on a >= 3 sigma level in the momentum range below 10 GeV/c. The required time resolution is <= 50 ps for single photon signal. In a preliminary R\\&D phase, we have shown that already commercially available micro-channel plate tubes with 8 x 8 channels fulfil the requirements. Timing properties of the tubes have been investigated with a pulsed laser diode in single photon regime. Key results from these laboratory tests are reported. An excellent timing resolution of <40 ps is achieved with an efficiency of similar to 90\\%. (C) 2011 Elsevier B.V. All rights reserved.