WorldWideScience

Sample records for chemical sensor combining

  1. Chemical sensors

    Science.gov (United States)

    Lowell, J.R. Jr.; Edlund, D.J.; Friesen, D.T.; Rayfield, G.W.

    1991-07-02

    Sensors responsive to small changes in the concentration of chemical species are disclosed. The sensors comprise a mechanochemically responsive polymeric film capable of expansion or contraction in response to a change in its chemical environment. They are operatively coupled to a transducer capable of directly converting the expansion or contraction to a measurable electrical response. 9 figures.

  2. Capacitive chemical sensor

    Science.gov (United States)

    Manginell, Ronald P; Moorman, Matthew W; Wheeler, David R

    2014-05-27

    A microfabricated capacitive chemical sensor can be used as an autonomous chemical sensor or as an analyte-sensitive chemical preconcentrator in a larger microanalytical system. The capacitive chemical sensor detects changes in sensing film dielectric properties, such as the dielectric constant, conductivity, or dimensionality. These changes result from the interaction of a target analyte with the sensing film. This capability provides a low-power, self-heating chemical sensor suitable for remote and unattended sensing applications. The capacitive chemical sensor also enables a smart, analyte-sensitive chemical preconcentrator. After sorption of the sample by the sensing film, the film can be rapidly heated to release the sample for further analysis. Therefore, the capacitive chemical sensor can optimize the sample collection time prior to release to enable the rapid and accurate analysis of analytes by a microanalytical system.

  3. Wearable Optical Chemical Sensors

    Science.gov (United States)

    Lobnik, Aleksandra

    Wearable sensors can be used to provide valuable information about the wearer's health and/or monitor the wearer's surroundings, identify safety concerns and detect threats, during the wearer's daily routine within his or her natural environment. The "sensor on a textile", an integrated sensor capable of analyzing data, would enable early many forms of detection. Moreover, a sensor connected with a smart delivery system could simultaneously provide comfort and monitoring (for safety and/or health), non-invasive measurements, no laboratory sampling, continuous monitoring during the daily activity of the person, and possible multi-parameter analysis and monitoring. However, in order for the technology to be accessible, it must remain innocuous and impose a minimal intrusion on the daily activities of the wearer. Therefore, such wearable technologies should be soft, flexible, and washable in order to meet the expectations of normal clothing. Optical chemical sensors (OCSs) could be used as wearable technology since they can be embedded into textile structures by using conventional dyeing, printing processes and coatings, while fiber-optic chemical sensors (FOCSs) as well as nanofiber sensors (NFSs) can be incorporated by weaving, knitting or laminating. The interest in small, robust and sensitive sensors that can be embedded into textile structures is increasing and the research activity on this topic is an important issue.

  4. Distributed Least-Squares Estimation of a Remote Chemical Source via Convex Combination in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Meng-Li Cao

    2014-06-01

    Full Text Available This paper investigates the problem of locating a continuous chemical source using the concentration measurements provided by a wireless sensor network (WSN. Such a problem exists in various applications: eliminating explosives or drugs, detecting the leakage of noxious chemicals, etc. The limited power and bandwidth of WSNs have motivated collaborative in-network processing which is the focus of this paper. We propose a novel distributed least-squares estimation (DLSE method to solve the chemical source localization (CSL problem using a WSN. The DLSE method is realized by iteratively conducting convex combination of the locally estimated chemical source locations in a distributed manner. Performance assessments of our method are conducted using both simulations and real experiments. In the experiments, we propose a fitting method to identify both the release rate and the eddy diffusivity. The results show that the proposed DLSE method can overcome the negative interference of local minima and saddle points of the objective function, which would hinder the convergence of local search methods, especially in the case of locating a remote chemical source.

  5. Combining Non Selective Gas Sensors on a Mobile Robot for Identification and Mapping of Multiple Chemical Compounds

    Directory of Open Access Journals (Sweden)

    Victor Hernandez Bennetts

    2014-09-01

    Full Text Available In this paper, we address the task of gas distribution modeling in scenarios where multiple heterogeneous compounds are present. Gas distribution modeling is particularly useful in emission monitoring applications where spatial representations of the gaseous patches can be used to identify emission hot spots. In realistic environments, the presence of multiple chemicals is expected and therefore, gas discrimination has to be incorporated in the modeling process. The approach presented in this work addresses the task of gas distribution modeling by combining different non selective gas sensors. Gas discrimination is addressed with an open sampling system, composed by an array of metal oxide sensors and a probabilistic algorithm tailored to uncontrolled environments. For each of the identified compounds, the mapping algorithm generates a calibrated gas distribution model using the classification uncertainty and the concentration readings acquired with a photo ionization detector. The meta parameters of the proposed modeling algorithm are automatically learned from the data. The approach was validated with a gas sensitive robot patrolling outdoor and indoor scenarios, where two different chemicals were released simultaneously. The experimental results show that the generated multi compound maps can be used to accurately predict the location of emitting gas sources.

  6. Combining non selective gas sensors on a mobile robot for identification and mapping of multiple chemical compounds.

    Science.gov (United States)

    Bennetts, Victor Hernandez; Schaffernicht, Erik; Pomareda, Victor; Lilienthal, Achim J; Marco, Santiago; Trincavelli, Marco

    2014-09-17

    In this paper, we address the task of gas distribution modeling in scenarios where multiple heterogeneous compounds are present. Gas distribution modeling is particularly useful in emission monitoring applications where spatial representations of the gaseous patches can be used to identify emission hot spots. In realistic environments, the presence of multiple chemicals is expected and therefore, gas discrimination has to be incorporated in the modeling process. The approach presented in this work addresses the task of gas distribution modeling by combining different non selective gas sensors. Gas discrimination is addressed with an open sampling system, composed by an array of metal oxide sensors and a probabilistic algorithm tailored to uncontrolled environments. For each of the identified compounds, the mapping algorithm generates a calibrated gas distribution model using the classification uncertainty and the concentration readings acquired with a photo ionization detector. The meta parameters of the proposed modeling algorithm are automatically learned from the data. The approach was validated with a gas sensitive robot patrolling outdoor and indoor scenarios, where two different chemicals were released simultaneously. The experimental results show that the generated multi compound maps can be used to accurately predict the location of emitting gas sources.

  7. IN-SITU IONIC CHEMICAL ANALYSIS OF FRESH WATER VIA A NOVEL COMBINED MULTI-SENSOR / SIGNAL PROCESSING ARCHITECTURE

    Science.gov (United States)

    Mueller, A. V.; Hemond, H.

    2009-12-01

    The capability for comprehensive, real-time, in-situ characterization of the chemical constituents of natural waters is a powerful tool for the advancement of the ecological and geochemical sciences, e.g. by facilitating rapid high-resolution adaptive sampling campaigns and avoiding the potential errors and high costs related to traditional grab sample collection, transportation and analysis. Portable field-ready instrumentation also promotes the goals of large-scale monitoring networks, such as CUASHI and WATERS, without the financial and human resources overhead required for traditional sampling at this scale. Problems of environmental remediation and monitoring of industrial waste waters would additionally benefit from such instrumental capacity. In-situ measurement of all major ions contributing to the charge makeup of natural fresh water is thus pursued via a combined multi-sensor/multivariate signal processing architecture. The instrument is based primarily on commercial electrochemical sensors, e.g. ion selective electrodes (ISEs) and ion selective field-effect transistors (ISFETs), to promote low cost as well as easy maintenance and reproduction,. The system employs a novel architecture of multivariate signal processing to extract accurate information from in-situ data streams via an "unmixing" process that accounts for sensor non-linearities at low concentrations, as well as sensor cross-reactivities. Conductivity, charge neutrality and temperature are applied as additional mathematical constraints on the chemical state of the system. Including such non-ionic information assists in obtaining accurate and useful calibrations even in the non-linear portion of the sensor response curves, and measurements can be made without the traditionally-required standard additions or ionic strength adjustment. Initial work demonstrates the effectiveness of this methodology at predicting inorganic cations (Na+, NH4+, H+, Ca2+, and K+) in a simplified system containing

  8. Fiber Bragg distributed chemical sensor

    NARCIS (Netherlands)

    Boersma, A.; Cheng, L.K.; Jansen, T.H.

    2010-01-01

    A distributed chemical sensor is developed by coating multiple Bragg gratings in a fibre with chemical selective responsive coatings. The optical response of the coated grating is optimised and the recoat process is very reproducible.

  9. Imprinted photonic crystal chemical sensors

    NARCIS (Netherlands)

    Boersma, A.; Burghoorn, M.M.A.; Saalmink, M.

    2011-01-01

    In this paper we present the use of Photonic Crystals as chemical sensors. These 2D nanostructured sensors were prepared by nano-imprint lithography during which a nanostructure is transferred from a nickel template into a responsive polymer, that is be specifically tuned to interact with the chemic

  10. Errors in Chemical Sensor Measurements

    Directory of Open Access Journals (Sweden)

    Artur Dybko

    2001-06-01

    Full Text Available Various types of errors during the measurements of ion-selective electrodes, ionsensitive field effect transistors, and fibre optic chemical sensors are described. The errors were divided according to their nature and place of origin into chemical, instrumental and non-chemical. The influence of interfering ions, leakage of the membrane components, liquid junction potential as well as sensor wiring, ambient light and temperature is presented.

  11. Nanomaterials and Chemical Sensors

    Directory of Open Access Journals (Sweden)

    Sukumar BASU

    2011-11-01

    Full Text Available Nanomaterials and nanosensors are two most important iconic words of the modern science & Technology. Though nano technology is relatively a new area of research & development it will soon be included in the most modern electronic circuitry used for advanced computing systems. Since it will provide the potential link between the nanotechnology and the macroscopic world the development is primarily directed towards exploitation of nanotechnology to computer chip miniaturization and vast storage capacity. However, for implementation in the consumer products the present high cost of production must be overcome. There are different ways to make nanosensors e.g. top-down lithography, bottom-up assembly, and self molecular assembly. Consequently, nanomaterials & nanosensors have to be made compatible with the consumer technologies. The progress in detecting and sensing different chemical species with increased accuracy may transform the human society from uncertainty and inaccuracy to more precise and definite world of information. For example, extremely low concentrations of air pollutants or toxic materials in air & water around us can be accurately and economically detected in no time to save the human beings from the serious illnesses. Also, the medical sensors will help in diagnoses of the diseases, their treatment and in predicting the future profile of the individual so that the health insurance companies may exploit the opportunity to grant or to deny the health coverage. Other social issues like privacy invasion and security may be best monitored by the widespread use of the surveillance devices using nanosensors.

  12. Fiber Bragg distributed chemical sensor

    NARCIS (Netherlands)

    Boersma, A.; Saalmink, M.; Lucassen, T.; Wiegersma, S.; Jansen, T.H.; Jansen, R.; Cheng, L.K.

    2011-01-01

    A distributed chemical sensor is developed by coating multiple Bragg gratings in a single glass fiber with chemical responsive coatings. The composition of the coating is tuned to the target chemicals to be measured and the optical response of the coated grating is optimized by changing the coating

  13. Graphene Chemical Sensor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The sensor uses graphene based devices to sense the surface potential of a graphene channel exposed to an analyte. When analyte molecules adsorb onto the...

  14. Graphene Chemical Sensor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The sensor uses graphene based devices to sense the surface potential of a graphene channel exposed to an analyte. When analyte molecules adsorb onto the...

  15. Microfabricated Chemical Gas Sensors and Sensor Arrays for Aerospace Applications

    Science.gov (United States)

    Hunter, Gary W.

    2005-01-01

    Aerospace applications require the development of chemical sensors with capabilities beyond those of commercially available sensors. In particular, factors such as minimal sensor size, weight, and power consumption are particularly important. Development areas which have potential aerospace applications include launch vehicle leak detection, engine health monitoring, and fire detection. Sensor development for these applications is based on progress in three types of technology: 1) Micromachining and microfabrication (Microsystem) technology to fabricate miniaturized sensors; 2) The use of nanocrystalline materials to develop sensors with improved stability combined with higher sensitivity; 3) The development of high temperature semiconductors, especially silicon carbide. This presentation discusses the needs of space applications as well as the point-contact sensor technology and sensor arrays being developed to address these needs. Sensors to measure hydrogen, hydrocarbons, nitrogen oxides (NO,), carbon monoxide, oxygen, and carbon dioxide are being developed as well as arrays for leak, fire, and emissions detection. Demonstrations of the technology will also be discussed. It is concluded that microfabricated sensor technology has significant potential for use in a range of aerospace applications.

  16. Combined sensor noise-immunity

    Institute of Scientific and Technical Information of China (English)

    Vladimir A. Shchurov; Alexander V. Shchurov

    2002-01-01

    The paper presents statistical analysis of combined sensor noise-immunity while recording fluctuating tone against underwater dynamic noise background. The experimental data used for the analysis have been collected by a pair of four-component combined sensors centered at two depths, 150 and 300 m in deep water. Expressions for combined sensor signalto-noise ratio (SNR) for cross-spectral levels of signal and noise for both wide and narrow frequency bands have been derived. A combined sensor gain has been introduced in terms of ordinary single-point coherence function between acoustic pressure and particle velocity in acoustic wave. The estimates obtained experimentally evidence that SNR for a combined sensor with multiplicative data processing may exceed SNR for a hydrophone-based sensor by 15 to 16 dB at most for the horizontal channel of the combined sensor, and by 30 dB at most for the vertical channel (when opposite energy flows of signal and noise compensate one another).

  17. Coordinated sensor cueing for chemical plume detection

    Science.gov (United States)

    Abraham, Nathan J.; Jensenius, Andrea M.; Watkins, Adam S.; Hawthorne, R. Chad; Stepnitz, Brian J.

    2011-05-01

    This paper describes an organic data fusion and sensor cueing approach for Chemical, Biological, Radiological, and Nuclear (CBRN) sensors. The Joint Warning and Reporting Network (JWARN) uses a hardware component referred to as the JWARN Component Interface Device (JCID). The Edgewood Chemical and Biological Center has developed a small footprint and open architecture solution for the JCID capability called JCID-on-a-Chip (JoaC). The JoaC program aims to reduce the cost and complexity of the JCID by shrinking the necessary functionality down to a small single board computer. This effort focused on development of a fusion and cueing algorithm organic to the JoaC hardware. By embedding this capability in the JoaC, sensors have the ability to receive and process cues from other sensors without the use of a complex and costly centralized infrastructure. Additionally, the JoaC software is hardware agnostic, as evidenced by its drop-in inclusion in two different system-on-a-chip platforms including Windows CE and LINUX environments. In this effort, a partnership between JPM-CA, JHU/APL, and the Edgewood Chemical and Biological Center (ECBC), the authors implemented and demonstrated a new algorithm for cooperative detection and localization of a chemical agent plume. This experiment used a pair of mobile Joint Services Lightweight Standoff Chemical Agent Detector (JSLSCAD) units which were controlled by fusion and cueing algorithms hosted on a JoaC. The algorithms embedded in the JoaC enabled the two sensor systems to perform cross cueing and cooperatively form a higher fidelity estimate of chemical releases by combining sensor readings. Additionally, each JSLSCAD had the ability to focus its search on smaller regions than those required by a single sensor system by using the cross cue information from the other sensor.

  18. Fiber Optic Chemical Sensors

    Science.gov (United States)

    1993-10-01

    Studies Press Ltd, Book Chapter, AIS, 1-25, 1983. Saarl, Linda A. and Seltz, Rudolf W., "Immobilized Morin as Fluorescence Sensor for Determination...34Thin Films," Photonics Spectra, AVO, AIS, 113-118, 1988. Hanst, Philip L. and Stephens, Edgar R., "Infrared Analysis of Engine Exhausts: Methyl...79-84, 1988. Watson, Jr., Edgar , "On-line Analysis of Trace Contaminants 145 36 in Process Streams," Amarican Laboratory, AVO, AIS, 97-101, 1988

  19. Nanoscale chemical sensor based on organic thin-film transistors

    Science.gov (United States)

    Wang, Liang; Fine, Daniel; Dodabalapur, Ananth

    2004-12-01

    Nanoscale organic thin-film transistors were fabricated to investigate their chemical sensing properties. The use of a four-terminal geometry ensures that the sensor active area is truly nanoscale, and eliminates undesirable spreading currents. The sensor response was markedly different in nanoscale sensors compared to large-area sensors for the same analyte-semiconductor combination. The chemical sensing mechanisms in both microscale and nanoscale transistors are briefly discussed.

  20. Miniature Chemical Sensor

    Energy Technology Data Exchange (ETDEWEB)

    Andrew C. R. Pipino

    2004-12-13

    A new chemical detection technology has been realized that addresses DOE environmental management needs. The new technology is based on a variant of the sensitive optical absorption technique, cavity ring-down spectroscopy (CRDS). Termed evanescent-wave cavity ring-down spectroscopy (EW-CRDS), the technology employs a miniature solid-state optical resonator having an extremely high Q-factor as the sensing element, where the high-Q is achieved by using ultra-low-attenuation optical materials, ultra-smooth surfaces, and ultra-high reflectivity coatings, as well as low-diffraction-loss designs. At least one total-internal reflection (TIR) mirror is integral to the resonator permitting the concomitant evanescent wave to probe the ambient environment. Several prototypes have been designed, fabricated, characterized, and applied to chemical detection. Moreover, extensions of the sensing concept have been explored to enhance selectivity, sensitivity, and range of application. Operating primarily in the visible and near IR regions, the technology inherently enables remote detection by optical fiber. Producing 11 archival publications, 5 patents, 19 invited talks, 4 conference proceedings, a CRADA, and a patent-license agreement, the project has realized a new chemical detection technology providing >100 times more sensitivity than comparable technologies, while also providing practical advantages.

  1. Integrated opto-chemical sensors

    NARCIS (Netherlands)

    Lambeck, Paul V.

    1992-01-01

    Integrated opto-chemical sensors have promising prospects, for example by having the potential to be realized as very sensitive small monolithic smart multisensor systems with a digital signal output. Here the main accent will be laid on the optical principles underlying chemo-optical waveguiding se

  2. Advanced millimeter wave chemical sensor.

    Energy Technology Data Exchange (ETDEWEB)

    Gopalsami, N.

    1999-03-24

    This paper discusses the development of an advanced millimeter-wave (mm-wave) chemical sensor and its applications for environmental monitoring and arms control treaty verification. The purpose of this work is to investigate the use of fingerprint-type molecular rotational signatures in the mm-wave spectrum to sense airborne chemicals. The mm-wave spectrum to sense airborne chemicals. The mm-wave sensor, operating in the frequency range of 220-300 GHz, can work under all weather conditions and in smoky and dusty environments. The basic configuration of the mm-wave sensor is a monostatic swept-frequency radar consisting of a mm-wave sweeper, a hot-electron-bolometer or Schottky barrier detector, and a trihedral reflector. The chemical plume to be detected is situated between the transmitter/detector and the reflector. Millimeter-wave absorption spectra of chemicals in the plume are determined by measuring the swept-frequency radar return signals with and without the plume in the beam path. The problem of pressure broadening, which hampered open-path spectroscopy in the past, has been mitigated in this work by designing a fast sweeping source over a broad frequency range. The heart of the system is a Russian backward-wave oscillator (BWO) tube that can be tuned over 220-350 GHz. Using the Russian BWO tube, a mm-wave radar system was built and field-tested at the DOE Nevada Test Site at a standoff distance of 60 m. The mm-wave system detected chemical plumes very well; the detection sensitivity for polar molecules like methyl chloride was down to a concentration of 12 ppm.

  3. Ubiquitous Sensor Network for Chemical Sensors

    Institute of Scientific and Technical Information of China (English)

    Wan-Young Chung; Risto Myllylae

    2006-01-01

    Wireless sensor networks have been identified as one of the most important technologies for the 21st century. Recent advances in micro sensor fabrication technology and wireless communication technology enable the practical deployment of large-scale, low-power, inexpensive sensor networks. Such an approach offers an advantage over traditional sensing methods in many ways: large-scale, dense deployment not only extends spatial coverage and achieves higher resolution, but also increases the system's fault-tolerance and robustness. Moreover, the ad-hoc nature of wireless sensor networks makes them even more attractive for military and other risk-associated applications, such as environmental observation and habitat monitoring.

  4. Guard Cell and Tropomyosin Inspired Chemical Sensor

    Directory of Open Access Journals (Sweden)

    Jacquelyn K.S. Nagel

    2013-10-01

    Full Text Available Sensors are an integral part of many engineered products and systems. Biological inspiration has the potential to improve current sensor designs as well as inspire innovative ones. This paper presents the design of an innovative, biologically-inspired chemical sensor that performs “up-front” processing through mechanical means. Inspiration from the physiology (function of the guard cell coupled with the morphology (form and physiology of tropomyosin resulted in two concept variants for the chemical sensor. Applications of the sensor design include environmental monitoring of harmful gases, and a non-invasive approach to detect illnesses including diabetes, liver disease, and cancer on the breath.

  5. Nanotube-Based Chemical and Biomolecular Sensors

    Institute of Scientific and Technical Information of China (English)

    J.Koh; B.Kim; S.Hong; H.Lim; H.C.Choi

    2008-01-01

    We present a brief review about recent results regarding carbon nanotube (CNT)-based chemical and biomolecular sensors. For the fabrication of CNT-based sensors, devices containing CNT channels between two metal electrodes are first fabricated usually via chemical vapor deposition (CVD) process or "surface programmed assembly" method. Then, the CNT surfaces are often functionalized to enhance the selectivity of the sensors. Using this process, highly-sensitive CNT-based sensors can be fabricated for the selective detection of various chemical and biological molecules such as hydrogen, ammonia, carbon monoxide, chlorine gas, DNA, glucose, alcohol, and proteins.

  6. Passive in-situ chemical sensor

    Science.gov (United States)

    Morrell, Jonathan S.; Ripley, Edward B.

    2012-02-14

    A chemical sensor for assessing a chemical of interest. In typical embodiments the chemical sensor includes a first thermocouple and second thermocouple. A reactive component is typically disposed proximal to the second thermal couple, and is selected to react with the chemical of interest and generate a temperature variation that may be detected by a comparison of a temperature sensed by the second thermocouple compared with a concurrent temperature detected by the first thermocouple. Further disclosed is a method for assessing a chemical of interest and a method for identifying a reaction temperature for a chemical of interest in a system.

  7. Development of Microfabricated Chemical Gas Sensors and Sensor Arrays for Aerospace Applications

    Science.gov (United States)

    Hunter, G. W.; Neudeck, P. G.; Fralick, G.; Thomas, V.; Liu, C. C.; Wu, W. H.; Ward, B.; Makel, D.

    2002-01-01

    Aerospace applications require the development of chemical sensors with capabilities beyond those of commercially available sensors. In particular, factors such as minimal sensor size, weight, and power consumption are particularly important. Development areas which have potential aerospace applications include launch vehicle leak detection, engine health monitoring, fire detection, and environmental monitoring. Sensor development for these applications is based on progress in three types of technology: 1) Micromachining and microfabrication (Microsystem) technology to fabricate miniaturized sensors. 2) The use of nanocrystalline materials to develop sensors with improved stability combined with higher sensitivity. 3) The development of high temperature semiconductors, especially silicon carbide. However, due to issues of selectivity and cross-sensitivity, individual sensors are limited in the amount of information that they can provide in environments that contain multiple chemical species. Thus, sensor arrays are being developed to address detection needs in such multi-species environments. This paper discusses the needs of space applications as well as the point-contact sensor technology and sensor arrays being developed to address these needs. Sensors to measure hydrogen, hydrocarbons, hydrazine, nitrogen oxides (NO,), carbon monoxide, oxygen, and carbon dioxide are being developed as well as arrays for leak, fire, and emissions detection. Demonstrations of the technology will also be discussed. It is concluded that microfabricated sensor technology has significant potential for use in a range of aerospace applications.

  8. Polymers for Chemical Sensors Using Hydrosilylation Chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Grate, Jay W.; Kaganove, Steven N.; Nelson, David A.

    2001-06-28

    Sorbent and functionalized polymers play a key role in a diverse set of fields, including chemical sensors, separation membranes, solid phase extraction techniques, and chromatography. Sorbent polymers are critical to a number of sensor array or "electronic nose" systems. The responses of the sensors in the array give rise to patterns that can be used to distinguish one compound from another, provided that a sufficiently diverse set of sensing materials is present in the array. Figure 1 illustrates the concept of several sensors, each with a different sensor coating, giving rise to variable responses to an analyte that appear as a pattern in bar graph format. Using hydrosilylation as the bond-forming reaction, we have developed a versatile and efficient approach to developing sorbent polymers with diverse interactive properties for sensor applications. Both the chemical and physical properties of these polymers are predictable and tunable by design.

  9. Autonomous chemical and biological miniature wireless-sensor

    Science.gov (United States)

    Goldberg, Bar-Giora

    2005-05-01

    would take place within the miniature, low cost distributed sensor platforms. This concept however presents a significant challenge due to a combination and convergence of required new technologies, as mentioned above. Passive biological and chemical sensors with very high sensitivity and which require no assaying are in development using a technique to optically and chemically encode silicon wafers with tailored nanostructures. The silicon wafer is patterned with nano-structures designed to change colors ad patterns when exposed to the target analytes (TICs, TIMs, VOC). A small video camera detects the color and pattern changes on the sensor. To determine if an alarm condition is present, an on board DSP processor, using specialized image processing algorithms and statistical analysis, determines if color gradient changes occurred on the sensor array. These sensors can detect several agents simultaneously. This system is currently under development by Avaak, with funding from DARPA through an SBIR grant.

  10. Small, Inexpensive Combined NOx Sensor and O2 Sensor

    Energy Technology Data Exchange (ETDEWEB)

    W. N. Lawless; C. F. Clark, Jr.

    2008-09-08

    It has been successfully demonstrated in this program that a zirconia multilayer structure with rhodium-based porous electrodes performs well as an amperometric NOx sensor. The sensitivity of the sensor bodies operating at 650 to 700 C is large, with demonstrated current outputs of 14 mA at 500 ppm NOx from sensors with 30 layers. The sensor bodies are small (4.5 x 4.2 x 3.1 mm), rugged, and inexpensive. It is projected the sensor bodies will cost $5 - $10 in production. This program has built on another successful development program for an oxygen sensor based on the same principles and sponsored by DOE. This oxygen sensor is not sensitive to NOx. A significant technical hurdle has been identified and solved. It was found that the 100% Rh electrodes oxidize rapidly at the preferred operating temperatures of 650 - 700 C, and this oxidation is accompanied by a volume change which delaminates the sensors. The problem was solved by using alloys of Rh and Pt. It was found that a 10%/90% Rh/Pt alloy dropped the oxidation rate of the electrodes by orders of magnitude without degrading the NOx sensitivity of the sensors, allowing long-term stable operation at the preferred operating temperatures. Degradation in the sensor output caused by temperature cycling was identified as a change in resistance at the junction between the sensor body and the external leads attached to the sensor body. The degradation was eliminated by providing strong mechanical anchors for the wire and processing the junctions to obtain good electrical bonds. The NOx sensors also detect oxygen and therefore the fully-packaged sensor needs to be enclosed with an oxygen sensor in a small, heated zirconia chamber exposed to test gas through a diffusion plug which limits the flow of gas from the outside. Oxygen is pumped from the interior of the chamber to lower the oxygen content and the combination of measurements from the NOx and oxygen sensors yields the NOx content of the gas. Two types of

  11. Graphene Chemical Sensor for Heliophysics Applications

    Science.gov (United States)

    Sultana, Mahmooda; Herrero, Fred; Khazanov, George

    2013-01-01

    Graphene is a single layer of carbon atoms that offer a unique set of advantages as a chemical sensor due to a number of its inherent properties. Graphene has been explored as a gas sensor for a variety of gases, and molecular sensitivity has been demonstrated by measuring the change in electrical properties due to the adsorption of target species. In this paper, we discuss the development of an array of chemical sensors based on graphene and its relevance to plasma physics due to its sensitivity to radical species such as oxonium, hydron and the corresponding neutrals. We briefly discuss the great impact such sensors will have on a number of heliophysics applications such as ground-based manifestations of space weather.

  12. Graphene chemical sensors for heliophysics applications

    Science.gov (United States)

    Sultana, Mahmooda; Herrero, Fred; Khazanov, George

    2013-10-01

    Graphene is a single layer of carbon atoms that offer a unique set of advantages as a chemical sensor due to a number of its inherent properties. Graphene has been explored as a gas sensor for a variety of gases, and molecular sensitivity has been demonstrated by measuring the change in electrical properties due to the adsorption of target species (Schedin, F.; Geim, A.K.; Morozov, S.V.; Hill, E.W.; Blake, P.; Katsnelson, M.I.; Novoselov, K.S. Nat. Mater 2007, 6, 652-655. doi:10.1038/nmat1967). In this paper, we discuss the development of an array of chemical sensors based on graphene and its relevance to plasma physics due to its sensitivity to radical species such as O+, H+ and the corresponding neutrals. We briefly discuss the great impact such sensors will have on a number of heliophysics applications such as ground-based manifestations of space weather.

  13. Micromachined chemical sensor with integrated microelectronics

    Science.gov (United States)

    Smith, J.; Sniegowski, J.; Koehler, D.; Ricco, T.; Martin, S.; McWhorter, P.

    With today's continued emphasis on environmental safety and health issues, a resurgence of interest has developed in the area of chemical sensors. These sensors would typically be used to monitor contamination hazards such as underground storage tanks or to assess previous contamination at waste disposal sites. Human exposure to chemical hazards can also be monitored. Additionally, these sensors can be used as part of a manufacturing process control loop. One type of sensor suitable for gas phase monitoring of chemicals is the quartz resonator or quartz crystal microbalance (QCM) sensor. In this type of sensor, a thickness shear mode (TSM) quartz resonator is coated with a film that interacts with the chemical species of interest. Changes in the mass and elasticity of this film are reflected as changes in the resonant properties of the device. Therefore, the presence of the species of interest can be detected by monitoring the frequency of an oscillator based on the resonance of the quartz. These QCM sensors compete with surface acoustic wave (SAW) devices as a means for monitoring gas phase species. SAW devices are typically more sensitive to small amounts of a species, but the instrumentation associated with a SAW device is an order of magnitude more expensive than the instrumentation associated with a TSM wave resonator since the SAW devices operate in the 100's of MHz frequency regime while quartz resonators operate in the 5-25 MHz regime. We are working to improve the sensitivity of the QCM sensor by increasing the frequency of the device to 25 MHz (compared to the typical 5 MHz crystal) and by increasing the frequency stability of the system to an ultimate goal of 0.1 Hz. The 25 MHz QCM has already been achieved, and once the stability goal is achieved, the QCM will have the same sensitivity as a SAW device.

  14. SAW Sensors for Chemical Vapors and Gases.

    Science.gov (United States)

    Devkota, Jagannath; Ohodnicki, Paul R; Greve, David W

    2017-04-08

    Surface acoustic wave (SAW) technology provides a sensitive platform for sensing chemicals in gaseous and fluidic states with the inherent advantages of passive and wireless operation. In this review, we provide a general overview on the fundamental aspects and some major advances of Rayleigh wave-based SAW sensors in sensing chemicals in a gaseous phase. In particular, we review the progress in general understanding of the SAW chemical sensing mechanism, optimization of the sensor characteristics, and the development of the sensors operational at different conditions. Based on previous publications, we suggest some appropriate sensing approaches for particular applications and identify new opportunities and needs for additional research in this area moving into the future.

  15. Chemical sensors technology development planning workshop

    Energy Technology Data Exchange (ETDEWEB)

    Bastiaans, G.J.; Haas, W.J. Jr.; Junk, G.A. [eds.

    1993-03-01

    The workshop participants were asked to: (1) Assess the current capabilities of chemical sensor technologies for addressing US Department of Energy (DOE) Environmental Restoration and Waste Management (EM) needs; (2) Estimate potential near term (one to two years) and intermediate term (three to five years) capabilities for addressing those needs; and (3) Generate a ranked list of specific recommendations on what research and development (R&D) should be funded to provide the necessary capabilities. The needs were described in terms of two pervasive EM problems, the in situ determination of chlorinated volatile organic compounds (VOCs), and selected metals in various matrices at DOE sites. The R&D recommendations were to be ranked according to the estimated likelihood that the product technology will be ready for application within the time frame it is needed and the estimated return on investment. The principal conclusions and recommendations of the workshop are as follows: Chemical sensors capable of in situ determinations can significantly reduce analytical costs; Chemical sensors have been developed for certain VOCs in gases and water but none are currently capable of in situ determination of VOCs in soils; The DOE need for in situ determination of metals in soils cannot be addressed with existing chemical sensors and the prospects for their availability in three to five years are uncertain; Adaptation, if necessary, and field application of laboratory analytical instruments and those few chemical sensors that are already in field testing is the best approach for the near term; The chemical sensor technology development plan should include balanced support for near- and intermediate-term efforts.

  16. Uncoated microcantilevers as chemical sensors

    Energy Technology Data Exchange (ETDEWEB)

    Thundat, Thomas G. (Knoxville, TN)

    2001-01-01

    A method and device are provided for chemical sensing using cantilevers that do not use chemically deposited, chemically specific layers. This novel device utilizes the adsorption-induced variation in the surfaces states on a cantilever. The methodology involves exciting charge carriers into or out of the surface states with photons having increasing discrete levels of energy. The excitation energy is provided as discrete levels of photon energy by scanning the wavelength of an exciting source that is illuminating the cantilever surface. When the charge carriers are excited into or out of the surface states, the cantilever bending changes due to changes in surface stress. The amount of cantilever bending with respect to an identical cantilever as a function of excitation energy is used to determine the energy levels associated with adsorbates.

  17. Chemical and natural stressors combined:

    DEFF Research Database (Denmark)

    Gergs, André; Zenker, Armin; Grimm, Volker

    2013-01-01

    In addition to natural stressors, populations are increasingly exposed to chemical pollutants released into the environment. We experimentally demonstrate the loss of resilience for Daphnia magna populations that are exposed to a combination of natural and chemical stressors even though effects...... on population size of a single stressor were cryptic, i.e. hard to detect statistically. Data on Daphnia population demography and along with model-based exploration of our predator-prey system revealed that direct trophic interactions changed the population size-structure and thereby increased population...... vulnerability to the toxicant which acts in a size selective manner. Moreover, population vulnerability to the toxicant increases with predator size and predation intensity whereas indirect trait-mediated interactions via predator kairomones may buffer chemical effects to a certain extent. Our study...

  18. Wide-Area Chemical Sensor

    Science.gov (United States)

    2014-11-01

    2014www.ll.mit.edu The detection and localization of gas releases such as methane from leaking natural gas pipelines or nitrogen oxides from failing electrical...reference gas cells, such as methane buffered by nitro- gen, and a low-concentration gas cell that contains the target species to calibrate the...self-referencing technique employed by WACS is particularly suited to detecting chemical agents composed of primarily small molecules— methane , various

  19. Integrated optical sensors for the chemical domain

    NARCIS (Netherlands)

    Lambeck, Paul V.

    2006-01-01

    During the last decade there has been a rapidly growing interest in integrated optical (IO) sensors, expecially because many of them principally allow for sensitive, real time, label-free-on-site measurements of the concentration of (bio-)chemical species. This review aims at giving an overview of t

  20. Integrated optical sensors for the chemical domain

    NARCIS (Netherlands)

    Lambeck, Paul

    2006-01-01

    During the last decade there has been a rapidly growing interest in integrated optical (IO) sensors, expecially because many of them principally allow for sensitive, real time, label-free-on-site measurements of the concentration of (bio-)chemical species. This review aims at giving an overview of t

  1. Electrostatic thin film chemical and biological sensor

    Science.gov (United States)

    Prelas, Mark A.; Ghosh, Tushar K.; Tompson, Jr., Robert V.; Viswanath, Dabir; Loyalka, Sudarshan K.

    2010-01-19

    A chemical and biological agent sensor includes an electrostatic thin film supported by a substrate. The film includes an electrostatic charged surface to attract predetermined biological and chemical agents of interest. A charge collector associated with said electrostatic thin film collects charge associated with surface defects in the electrostatic film induced by the predetermined biological and chemical agents of interest. A preferred sensing system includes a charge based deep level transient spectroscopy system to read out charges from the film and match responses to data sets regarding the agents of interest. A method for sensing biological and chemical agents includes providing a thin sensing film having a predetermined electrostatic charge. The film is exposed to an environment suspected of containing the biological and chemical agents. Quantum surface effects on the film are measured. Biological and/or chemical agents can be detected, identified and quantified based on the measured quantum surface effects.

  2. Piezoresistive Chemical Sensors Based on Functionalized Hydrogels

    Directory of Open Access Journals (Sweden)

    Margarita Guenther

    2014-06-01

    Full Text Available Thin films of analyte-specific hydrogels were combined with microfabricated piezoresistive pressure transducers to obtain chemomechanical sensors that can serve as selective biochemical sensors for a continuous monitoring of metabolites. The gel swelling pressure has been monitored in simulated physiological solutions by means of the output signal of piezoresistive sensors. The interference by fructose, human serum albumin, pH, and ionic concentration on glucose sensing was studied. With the help of a database containing the calibration curves of the hydrogel-based sensors at different values of pH and ionic strength, the corrected values of pH and glucose concentration were determined using a novel calibration algorithm.

  3. Conducting polymers in electronic chemical sensors.

    Science.gov (United States)

    Janata, Jiri; Josowicz, Mira

    2003-01-01

    Conducting organic polymers have found two main kinds of application in electronics so far: as materials for construction of various devices and as selective layers in chemical sensors. In either case, interaction with ambient gases is critical. It may compromise the performance of a device based on conducting polymers, whereas it is beneficial in a sensor. Conductivity has been the primary property of interest. Work function--related to conductivity, but in principle a different property--has received only scant attention. Our aim here is to discuss the usability of conducting polymers in both types of electronic applications in light of these two parameters.

  4. Modeling Microscopic Chemical Sensors in Capillaries

    CERN Document Server

    Hogg, Tad

    2008-01-01

    Nanotechnology-based microscopic robots could provide accurate in vivo measurement of chemicals in the bloodstream for detailed biological research and as an aid to medical treatment. Quantitative performance estimates of such devices require models of how chemicals in the blood diffuse to the devices. This paper models microscopic robots and red blood cells (erythrocytes) in capillaries using realistic distorted cell shapes. The models evaluate two sensing scenarios: robots moving with the cells past a chemical source on the vessel wall, and robots attached to the wall for longer-term chemical monitoring. Using axial symmetric geometry with realistic flow speeds and diffusion coefficients, we compare detection performance with a simpler model that does not include the cells. The average chemical absorption is quantitatively similar in both models, indicating the simpler model is an adequate design guide to sensor performance in capillaries. However, determining the variation in forces and absorption as cells...

  5. Biomimetic chemical sensors using bioengineered olfactory and taste cells

    OpenAIRE

    Du, Liping; Zou, Ling; Zhao, Luhang; Wang, Ping; Wu, Chunsheng

    2014-01-01

    Biological olfactory and taste systems are natural chemical sensing systems with unique performances for the detection of environmental chemical signals. With the advances in olfactory and taste transduction mechanisms, biomimetic chemical sensors have achieved significant progress due to their promising prospects and potential applications. Biomimetic chemical sensors exploit the unique capability of biological functional components for chemical sensing, which are often sourced from sensing ...

  6. TOPICAL REVIEW: Biological and chemical sensors for cancer diagnosis

    Science.gov (United States)

    Simon, Elfriede

    2010-11-01

    The great challenge for sensor systems to be accepted as a relevant diagnostic and therapeutic tool for cancer detection is the ability to determine the presence of relevant biomarkers or biomarker patterns comparably to or even better than the traditional analytical systems. Biosensor and chemical sensor technologies are already used for several clinical applications such as blood glucose or blood gas measurements. However, up to now not many sensors have been developed for cancer-related tests because only a few of the biomarkers have shown clinical relevance and the performance of the sensor systems is not always satisfactory. New genomic and proteomic tools are used to detect new molecular signatures and identify which combinations of biomarkers may detect best the presence or risk of cancer or monitor cancer therapies. These molecular signatures include genetic and epigenetic signatures, changes in gene expressions, protein biomarker profiles and other metabolite profile changes. They provide new changes in using different sensor technologies for cancer detection especially when complex biomarker patterns have to be analyzed. To address requirements for this complex analysis, there have been recent efforts to develop sensor arrays and new solutions (e.g. lab on a chip) in which sampling, preparation, high-throughput analysis and reporting are integrated. The ability of parallelization, miniaturization and the degree of automation are the focus of new developments and will be supported by nanotechnology approaches. This review recaps some scientific considerations about cancer diagnosis and cancer-related biomarkers, relevant biosensor and chemical sensor technologies, their application as cancer sensors and consideration about future challenges.

  7. Carbon Nanotube Based Chemical Sensors for Space and Terrestrial Applications

    Science.gov (United States)

    Li, Jing; Lu, Yijiang

    2009-01-01

    A nanosensor technology has been developed using nanostructures, such as single walled carbon nanotubes (SWNTs), on a pair of interdigitated electrodes (IDE) processed with a silicon-based microfabrication and micromachining technique. The IDE fingers were fabricated using photolithography and thin film metallization techniques. Both in-situ growth of nanostructure materials and casting of the nanostructure dispersions were used to make chemical sensing devices. These sensors have been exposed to nitrogen dioxide, acetone, benzene, nitrotoluene, chlorine, and ammonia in the concentration range of ppm to ppb at room temperature. The electronic molecular sensing of carbon nanotubes in our sensor platform can be understood by intra- and inter-tube electron modulation in terms of charge transfer mechanisms. As a result of the charge transfer, the conductance of p-type or hole-richer SWNTs in air will change. Due to the large surface area, low surface energy barrier and high thermal and mechanical stability, nanostructured chemical sensors potentially can offer higher sensitivity, lower power consumption and better robustness than the state-of-the-art systems, which make them more attractive for defense and space applications. Combined with MEMS technology, light weight and compact size sensors can be made in wafer scale with low cost. Additionally, a wireless capability of such a sensor chip can be used for networked mobile and fixed-site detection and warning systems for military bases, facilities and battlefield areas.

  8. Graphene-Based Chemical Vapor Sensors for Electronic Nose Applications

    Science.gov (United States)

    Nallon, Eric C.

    An electronic nose (e-nose) is a biologically inspired device designed to mimic the operation of the olfactory system. The e-nose utilizes a chemical sensor array consisting of broadly responsive vapor sensors, whose combined response produces a unique pattern for a given compound or mixture. The sensor array is inspired by the biological function of the receptor neurons found in the human olfactory system, which are inherently cross-reactive and respond to many different compounds. The use of an e-nose is an attractive approach to predict unknown odors and is used in many fields for quantitative and qualitative analysis. If properly designed, an e-nose has the potential to adapt to new odors it was not originally designed for through laboratory training and algorithm updates. This would eliminate the lengthy and costly R&D costs associated with materiel and product development. Although e-nose technology has been around for over two decades, much research is still being undertaken in order to find new and more diverse types of sensors. Graphene is a single-layer, 2D material comprised of carbon atoms arranged in a hexagonal lattice, with extraordinary electrical, mechanical, thermal and optical properties due to its 2D, sp2-bonded structure. Graphene has much potential as a chemical sensing material due to its 2D structure, which provides a surface entirely exposed to its surrounding environment. In this configuration, every carbon atom in graphene is a surface atom, providing the greatest possible surface area per unit volume, so that electron transport is highly sensitive to adsorbed molecular species. Graphene has gained much attention since its discovery in 2004, but has not been realized in many commercial electronics. It has the potential to be a revolutionary material for use in chemical sensors due to its excellent conductivity, large surface area, low noise, and versatile surface for functionalization. In this work, graphene is incorporated into a

  9. Microfabricated Chemical Sensors for Aerospace Fire Detection Applications

    Science.gov (United States)

    Hunter, Gary W.; Neudeck, Philip G.; Fralick, Gustave; Thomas, Valarie; Makel, D.; Liu, C. C.; Ward, B.; Wu, Q. H.

    2001-01-01

    The detection of fires on-board commercial aircraft is extremely important for safety reasons. Although dependable fire detection equipment presently exists within the cabin, detection of fire within the cargo hold has been less reliable and susceptible to false alarms. A second, independent method of fire detection to complement the conventional smoke detection techniques, such as the measurement of chemical species indicative of a fire, will help reduce false alarms and improve aircraft safety. Although many chemical species are indicative of a fire, two species of particular interest are CO and CO2. This paper discusses microfabricated chemical sensor development tailored to meet the needs of fire safety applications. This development is based on progress in three types of technology: 1) Micromachining and microfabrication (Microsystem) technology to fabricate miniaturized sensors. 2) The use of nanocrystalline materials to develop sensors with improved stability combined with higher sensitivity. 3) The development of high temperature semiconductors, especially silicon carbide. The individual sensor being developed and their level of maturity will be presented.

  10. Flexible optical chemical sensor platform for BTX

    OpenAIRE

    Arias Espinoza, Juan Diego; Sazhnikov, Viacheslav; Sabik, Sami; Ionov, Dmitriy; Smits, Edsger; Kalathimekkad, Sandeep; Van Steenberge, Geert; Alfimov, Michail; Posniak, Malgorzata; Schoo, Herman

    2012-01-01

    An in-plane flexible sensor platform for BTX detection was developed using low-cost patterning techniques and foil-based optical components. The platform was produced by a combination of laser patterning, inkjet printing and capillary filling. Key optical components such as lightguides, opticalcladding layers and metallic interconnections were realized on low cost substrates such as paper and PET. The sensing mechanism is based on the change in fluorescence spectra of a reporter dye, supporte...

  11. Waveguide-based optical chemical sensor

    Science.gov (United States)

    Grace, Karen M.; Swanson, Basil I.; Honkanen, Seppo

    2007-03-13

    The invention provides an apparatus and method for highly selective and sensitive chemical sensing. Two modes of laser light are transmitted through a waveguide, refracted by a thin film host reagent coating on the waveguide, and analyzed in a phase sensitive detector for changes in effective refractive index. Sensor specificity is based on the particular species selective thin films of host reagents which are attached to the surface of the planar optical waveguide. The thin film of host reagents refracts laser light at different refractive indices according to what species are forming inclusion complexes with the host reagents.

  12. Carbon-Nanotube-Based Chemical Gas Sensor

    Science.gov (United States)

    Kaul, Arunpama B.

    2010-01-01

    Conventional thermal conductivity gauges (e.g. Pirani gauges) lend themselves to applications such as leak detectors, or in gas chromatographs for identifying various gas species. However, these conventional gauges are physically large, operate at high power, and have a slow response time. A single-walled carbon-nanotube (SWNT)-based chemical sensing gauge relies on differences in thermal conductance of the respective gases surrounding the CNT as it is voltage-biased, as a means for chemical identification. Such a sensor provides benefits of significantly reduced size and compactness, fast response time, low-power operation, and inexpensive manufacturing since it can be batch-fabricated using Si integrated-circuit (IC) process technology.

  13. Nanostructure Engineered Chemical Sensors for Hazardous Gas and Vapor Detection

    Science.gov (United States)

    Li, Jing; Lu, Yijiang

    2005-01-01

    A nanosensor technology has been developed using nanostructures, such as single walled carbon nanotubes (SWNTs) and metal oxides nanowires or nanobelts, on a pair of interdigitated electrodes (IDE) processed with a silicon based microfabrication and micromachining technique. The IDE fingers were fabricated using thin film metallization techniques. Both in-situ growth of nanostructure materials and casting of the nanostructure dispersions were used to make chemical sensing devices. These sensors have been exposed to hazardous gases and vapors, such as acetone, benzene, chlorine, and ammonia in the concentration range of ppm to ppb at room temperature. The electronic molecular sensing in our sensor platform can be understood by electron modulation between the nanostructure engineered device and gas molecules. As a result of the electron modulation, the conductance of nanodevice will change. Due to the large surface area, low surface energy barrier and high thermal and mechanical stability, nanostructured chemical sensors potentially can offer higher sensitivity, lower power consumption and better robustness than the state-of-the-art systems, which make them more attractive for defense and space applications. Combined with MEMS technology, light weight and compact size sensors can be made in wafer scale with low cost.

  14. Development of GaN-based micro chemical sensor nodes

    Science.gov (United States)

    Son, Kyung-ah; Prokopuk, Nicholas; George, Thomas; Moon, Jeong S.

    2005-01-01

    Sensors based on III-N technology are gaining significant interest due to their potential for monolithic integration of RF transceivers and light sources and the capability of high temperature operations. We are developing a GaN-based micro chemical sensor node for remote detection of chemical toxins, and present electrical responses of AlGaN/GaN HEMT (High Electron Mobility Transistor) sensors to chemical toxins as well as other common gases.

  15. Progress of Mimetic Enzymes and Their Applications in Chemical Sensors.

    Science.gov (United States)

    Yang, Bin; Li, Jianping; Deng, Huan; Zhang, Lianming

    2016-11-01

    The need to develop innovative and reformative approaches to synthesize chemical sensors has increased in recent years because of demands for selectivity, stability, and reproducibility. Mimetic enzymes provide an efficient and convenient method for chemical sensors. This review summarizes the application of mimetic enzymes in chemical sensors. Mimetic enzymes can be classified into five categories: hydrolases, oxidoreductases, transferases, isomerases, and induced enzymes. Potential and recent applications of mimetic enzymes in chemical sensors are reviewed in detail, and the outlook of profound development has been illustrated.

  16. Micro Coriolis mass flow sensor for chemical micropropulsion systems

    NARCIS (Netherlands)

    Wiegerink, Remco J.; Lammerink, Theodorus S.J.; Groenesteijn, Jarno; Dijkstra, Pieter J.; Lötters, Joost Conrad

    2012-01-01

    We have designed a micromachined micro Coriolis flow sensor for the measurement of hydrazine (N2H4, High Purity Grade) propellant flow in micro chemical propulsion systems. The sensor measures mass flow up to 10 mg/s for a single thruster or up to 40 mg/s for four thrusters. The sensor will first be

  17. Design Of Piezoelectric Microcantilever Chemical Sensors In COMSOL Multiphysics Area

    OpenAIRE

    Maziar Norouzi; Alireza Kashaninia

    2009-01-01

    This paper offers an analytical modeling ofthin-filmed, multi-layer piezoelectric microcantileversthat are used as MEMS sensors. These sensors arechemical kind and use piezoelectric microcantilever.These types of microcantilevers are covered withvariety of unique probe coating. The sensor has highsensitivity with external voltage measured in mV anduses PSD1 system to indentify chemical ingredients ofmaterials. The identification of the chemical ingredientof materials is based on change in ang...

  18. Feature Selection for Chemical Sensor Arrays Using Mutual Information

    Science.gov (United States)

    Wang, X. Rosalind; Lizier, Joseph T.; Nowotny, Thomas; Berna, Amalia Z.; Prokopenko, Mikhail; Trowell, Stephen C.

    2014-01-01

    We address the problem of feature selection for classifying a diverse set of chemicals using an array of metal oxide sensors. Our aim is to evaluate a filter approach to feature selection with reference to previous work, which used a wrapper approach on the same data set, and established best features and upper bounds on classification performance. We selected feature sets that exhibit the maximal mutual information with the identity of the chemicals. The selected features closely match those found to perform well in the previous study using a wrapper approach to conduct an exhaustive search of all permitted feature combinations. By comparing the classification performance of support vector machines (using features selected by mutual information) with the performance observed in the previous study, we found that while our approach does not always give the maximum possible classification performance, it always selects features that achieve classification performance approaching the optimum obtained by exhaustive search. We performed further classification using the selected feature set with some common classifiers and found that, for the selected features, Bayesian Networks gave the best performance. Finally, we compared the observed classification performances with the performance of classifiers using randomly selected features. We found that the selected features consistently outperformed randomly selected features for all tested classifiers. The mutual information filter approach is therefore a computationally efficient method for selecting near optimal features for chemical sensor arrays. PMID:24595058

  19. Development and Application of Microfabricated Chemical Gas Sensors For Aerospace Applications

    Science.gov (United States)

    Hunter, G. W.; Neudeck, P. G.; Fralick, G.; Thomas, V.; Liu, C. C.; Wu, Q. H.; Sawayda, M. S.; Jin, A.; Hammond, J.; Makel, D.; Hall, G.

    1990-01-01

    Aerospace applications require the development of chemical sensors with capabilities beyond those of commercially available sensors. In particular, factors such as minimal sensor size, weight, and power consumption are particularly important. Development areas which have potential aerospace applications include launch vehicle leak detection, engine health monitoring and control, and fire detection. Sensor development for these applications is based on progress in three types of technology: 1) Micromachining and microfabrication (Microsystem) technology to fabricate miniaturized sensors. 2) The use of nanocrystalline materials to develop sensors with improved stability combined with higher sensitivity. 3) The development of high temperature semiconductors, especially silicon carbide. Sensor development for each application involves its own challenges in the fields of materials science and fabrication technology. This paper discusses the needs of space applications and the point-contact sensor technology being developed to address these needs. Sensors to measure hydrogen, hydrocarbons, nitrogen oxides (Nox, carbon monoxide, oxygen, and carbon dioxide are being developed. A description is given of each sensor type and its present stage of development. Demonstration and application these sensor technologies will be described. The demonstrations range from use of a microsystem based hydrogen sensor on the Shuttle to engine demonstration of a nanocrystalline based sensor for NO, detection. It is concluded that microfabricated sensor technology has significant potential for use in a range of aerospace applications.

  20. Evaluating Zeolite-Modified Sensors: towards a faster set of chemical sensors

    Science.gov (United States)

    Berna, A. Z.; Vergara, A.; Trincavelli, M.; Huerta, R.; Afonja, A.; Parkin, I. P.; Binions, R.; Trowell, S.

    2011-09-01

    The responses of zeolite-modified sensors, prepared by screen printing layers of chromium titanium oxide (CTO), were compared to unmodified tin oxide sensors using amplitude and transient responses. For transient responses we used a family of features, derived from the exponential moving average (EMA), to characterize chemo-resistive responses. All sensors were tested simultaneously against 20 individual volatile compounds from four chemical groups. The responses of the two types of sensors showed some independence. The zeolite-modified CTO sensors discriminated compounds better using either amplitude response or EMA features and CTO-modified sensors also responded three times faster.

  1. Development of chemical sensors by using beta emitters

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, H. J; Yu, S. K.; Yoon, M. O.; Park, K. S.; Rhim, G. J. [Kyung Hee University, Seoul (Korea)

    2000-04-01

    The objective of this project is development of core techniques for fabrication of biosensor. This includes a method for immobilization of biologically active molecules, a method for labelling target molecules with beta emitter, and a detection method based on beta counting. A radioimmuno-sensor for detection of DNA antibody, self-assembled monolayers of {omega}-carboxylated thiol molecules such as thioctic acid and 12-mercaptododecanoic acid were used in combination with chemical coupling methods. EDC (1 - ethyl - 3 [3 - (dimethylamino)propyl] carbodiimide) and NHS (N - hydroxy - succinimide) were used as coupling reagents to induce amide bond formation between the COOH group on the sensor surface and the -NH{sub 2} group on the antibody. Various experimental conditions such as COOH concentration, immobilization pH, reaction times etc, have been examined to establish optimum conditions for efficient immobilization of the antibody. Efficient labeling of the target antigen, DNA, with a beta emitter, {sup 35}S, was achieved by using the polymerase chain reaction (PCR) method. Detection of sensing signal from antigens that are selectively bound to the surface of the DNA radioimmuno-sensor has been accomplished by use of the beta counting method. According to the present results, efficient immobilization of the antibody is possible at very low antibody concentration below or equal to 0.1 mg/mL with detection limit reaching as low as 10{sup -11} M bp DNA concentration. 25 refs., 14 figs. (Author)

  2. Nanotechnologv Enabled Biological and Chemical Sensors

    Science.gov (United States)

    Koehne, Jessica; Meyyappan, M.

    2011-01-01

    Nanotechnology is an enabling technology that will impact almost all economic sectors: one of the most important and with great potential is the health/medical sector. - Nanomaterials for drug delivery - Early warning sensors - Implantable devices - Artificial parts with improved characteristics Carbon nanotubes and nanofibers show promise for use in sensor development, electrodes and other biomedical applications.

  3. Non-specific sensor arrays for chemical detection

    Science.gov (United States)

    Johnson, Kevin; Minor, Christian

    2015-05-01

    Non-specific chemical sensor arrays have been the subject of considerable research efforts over the past thirty years with the idea that, by analogy to vertebrate olfaction, they are potentially capable of rendering complex chemical assessments with relatively modest logistical footprints. However, the actual implementation of such devices in challenging "real world" scenarios has arguably continued to fall short of these expectations. This work examines the inherent limitations of such devices for complex chemical sensing scenarios, placing them on a continuum between simple univariate sensors and complex multivariate analytical instrumentation and analyzing their utility in general-purpose chemical detection and accurate chemical sensing in the presence of unknown "unknowns." Results with simulated and acquired data sets are presented with discussion of the implications in development of chemical sensor arrays suitable for complex scenarios.

  4. Optical chemical and biochemical sensors: new trends (Invited Paper)

    Science.gov (United States)

    Baldini, F.; Giannetti, A.

    2005-06-01

    Chemical and biochemical sensing is under the extensive research all over the world and many chemical and biochemical sensors are finding increasing number of applications in industry, environmental monitoring, medicine, biomedicine and chemical analysis. This is evidenced by each-year-growing number of international scientific conferences, in which advances in the field of the sensors are reported. One of the main reason why only a few sensors reach the international market, notwithstanding the high number of laboratory prototype described in many peer reviewed papers, lies in the fact that a biochemical sensor is a highly interdisciplinary "object" the realization of which requires the team work of scientists coming from different areas such as chemistry, physics, optoelectronics, engineering, biochemistry, and medicine. And this peculiarity is not easily found in the research teams. In the present paper, the fundamental bases of chemical and biochemical optical sensing are summarised and the new trends are described.

  5. Zirconia-based solid state chemical gas sensors

    CERN Document Server

    Zhuiykov, S

    2000-01-01

    This paper presents an overview of chemical gas sensors, based on solid state technology, that are sensitive to environmental gases, such as O sub 2 , SO sub x , NO sub x , CO sub 2 and hydrocarbons. The paper is focussed on performance of electrochemical gas sensors that are based on zirconia as a solid electrolyte. The paper considers sensor structures and selection of electrode materials. Impact of interfaces on sensor performance is discussed. This paper also provides a brief overview of electrochemical properties of zirconia and their effect on sensor performance. Impact of auxiliary materials on sensors performance characteristics, such as sensitivity, selectivity, response time and recovery time, is also discussed. Dual gas sensors that can be applied for simultaneous monitoring of the concentration of both oxygen and other gas phase components, are briefly considered

  6. Biomimetic chemical sensors using bioengineered olfactory and taste cells

    Science.gov (United States)

    Du, Liping; Zou, Ling; Zhao, Luhang; Wang, Ping; Wu, Chunsheng

    2014-01-01

    Biological olfactory and taste systems are natural chemical sensing systems with unique performances for the detection of environmental chemical signals. With the advances in olfactory and taste transduction mechanisms, biomimetic chemical sensors have achieved significant progress due to their promising prospects and potential applications. Biomimetic chemical sensors exploit the unique capability of biological functional components for chemical sensing, which are often sourced from sensing units of biological olfactory or taste systems at the tissue level, cellular level, or molecular level. Specifically, at the cellular level, there are mainly two categories of cells have been employed for the development of biomimetic chemical sensors, which are natural cells and bioengineered cells, respectively. Natural cells are directly isolated from biological olfactory and taste systems, which are convenient to achieve. However, natural cells often suffer from the undefined sensing properties and limited amount of identical cells. On the other hand, bioengineered cells have shown decisive advantages to be applied in the development of biomimetic chemical sensors due to the powerful biotechnology for the reconstruction of the cell sensing properties. Here, we briefly summarized the most recent advances of biomimetic chemical sensors using bioengineered olfactory and taste cells. The development challenges and future trends are discussed as well. PMID:25482234

  7. Plasmonics Based Harsh Environment Compatible Chemical Sensors

    Energy Technology Data Exchange (ETDEWEB)

    Michael Carpenter

    2012-01-15

    Au-YSZ, Au-TiO{sub 2} and Au-CeO{sub 2} nanocomposite films have been investigated as a potential sensing element for high-temperature plasmonic sensing of H{sub 2}, CO, and NO{sub 2} in an oxygen containing environment. The Au-YSZ and Au-TiO{sub 2} films were deposited using PVD methods, while the CeO{sub 2} thin film was deposited by molecular beam epitaxy (MBE) and Au was implanted into the as-grown film at an elevated temperature followed by high temperature annealing to form well-defined Au nanoclusters. Each of the films were characterized by x-ray diffraction (XRD) and Rutherford backscattering spectrometry (RBS). For the gas sensing experiments, separate exposures to varying concentrations of H{sub 2}, CO, and NO{sub 2} were performed at a temperature of 500°C in oxygen backgrounds of 5.0, 10, and ~21% O{sub 2}. Changes in the localized surface plasmon resonance (LSPR) absorption peak were monitored during gas exposures and are believed to be the result of oxidation-reduction processes that fill or create oxygen vacancies in the respective metal oxides. This process affects the LSPR peak position either by charge exchange with the Au nanoparticles or by changes in the dielectric constant surrounding the particles. Hyperspectral multivariate analysis was used to gauge the inherent selectivity of the film between the separate analytes. From principal component analysis (PCA), unique and identifiable responses were seen for each of the analytes. Linear discriminant analysis (LDA) was also used on the Au-CeO{sub 2} results and showed separation between analytes as well as trends in gas concentration. Results indicate that each of the films are is selective towards O{sub 2}, H{sub 2}, CO, and NO{sub 2} in separate exposures. However, when the films were analyzed in a sensor array based experiment, ie simultaneous exposures to the target gases, PCA analysis of the combined response showed an even greater selective character towards the target gases. Combined

  8. Multi-Sensor Integration to Map Odor Distribution for the Detection of Chemical Sources

    Directory of Open Access Journals (Sweden)

    Xiang Gao

    2016-07-01

    Full Text Available This paper addresses the problem of mapping odor distribution derived from a chemical source using multi-sensor integration and reasoning system design. Odor localization is the problem of finding the source of an odor or other volatile chemical. Most localization methods require a mobile vehicle to follow an odor plume along its entire path, which is time consuming and may be especially difficult in a cluttered environment. To solve both of the above challenges, this paper proposes a novel algorithm that combines data from odor and anemometer sensors, and combine sensors’ data at different positions. Initially, a multi-sensor integration method, together with the path of airflow was used to map the pattern of odor particle movement. Then, more sensors are introduced at specific regions to determine the probable location of the odor source. Finally, the results of odor source location simulation and a real experiment are presented.

  9. Bragg grating chemical sensor with hydrogel as sensitive element

    Institute of Scientific and Technical Information of China (English)

    Xiaomei Liu(刘小梅); Shilie Zheng(郑史烈); Xianmin Zhang(章献民); Jun Cong(丛军); Kangsheng Chen(陈抗生); Jian Xu(徐坚)

    2004-01-01

    A novel fiber Bragg grating (FBG) based chemical sensor using hydrogel, a swellable polymer, as sensitive element is demonstrated. The sensing mechanism relies on the shift of Bragg wavelength due to the stress resulted from volume change of sensitive swellable hydrogel responding to the change of external environment. A polyacrylamide hydrogel fiber grating chemical sensor is made, and the experiments on its sensitivity to the salinity are performed. The sensitivity is low due to the less stress from the shrinking or swelling of hydrogels. Reducing the cross diameter of the grating through etching with hydrofluoric acid can greatly improve the sensitivity of the sensor.

  10. Utilization of biosensors and chemical sensors for space applications

    Science.gov (United States)

    Bonting, S. L.

    1992-01-01

    There will be a need for a wide array of chemical sensors for biomedical experimentation and for the monitoring of water and air recycling processes on Space Station Freedom. The infrequent logistics flights of the Space Shuttle will necessitate onboard analysis. The advantages of biosensors and chemical sensors over conventional analysis onboard spacecraft are manifold. They require less crew time, space, and power. Sample treatment is not needed. Real time or near-real time monitoring is possible, in some cases on a continuous basis. Sensor signals in digitized form can be transmitted to the ground. Types and requirements for chemical sensors to be used in biomedical experimentation and monitoring of water recycling during long-term space missions are discussed.

  11. Chemical Sensors Based on Piezoresistive Cantilever Array

    Institute of Scientific and Technical Information of China (English)

    于晓梅; 张大成; 王丛舜; 杜先锋; 王小宝; 阮勇

    2003-01-01

    U-shaped and rectangle piezoresistive cantilever arrays have been designed with the analysing results of stress,noise and sensitivity of the cantilevers. Based on silicon micromachining technology, the piezoresistive cantilevers were fabricated by using polysilicon as the piezoresistive materials. With the measurement results of noise and sensitivity, the Hooge factor is calculated to be 3 × 10-3, the gauge factor is 27, and the minimum detectable deflection of piezoresistive cantilevers are calculated to be 1.0nm for rectangle cantilever and 0.5 nm for the Ushaped cantilever at a 6 V bias voltage and a 1000 Hz measurement bandwidth. Using polymer-coated cantilevers as individual sensors, their responses to water vapour and ammonia were tested by measuring their output voltage signals. The measured results show that the sensor sensitivity to ammonia can reach a few ppm and the sensor responses are quick.

  12. Combine harvester monitor system based on wireless sensor network

    Science.gov (United States)

    A measurement method based on Wireless Sensor Network (WSN) was developed to monitor the working condition of combine harvester for remote application. Three JN5139 modules were chosen for sensor data acquisition and another two as a router and a coordinator, which could create a tree topology netwo...

  13. Carbon Nanotube-Based Chemical Sensors.

    Science.gov (United States)

    Meyyappan, M

    2016-04-27

    The need to sense gases and vapors arises in numerous scenarios in industrial, environmental, security and medical applications. Traditionally, this activity has utilized bulky instruments to obtain both qualitative and quantitative information on the constituents of the gas mixture. It is ideal to use sensors for this purpose since they are smaller in size and less expensive; however, their performance in the field must match that of established analytical instruments in order to gain acceptance. In this regard, nanomaterials as sensing media offer advantages in sensitivity, preparation of chip-based sensors and construction of electronic nose for selective detection of analytes of interest. This article provides a review of the use of carbon nanotubes in gas and vapor sensing. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Solution-gated graphene transistors for chemical and biological sensors.

    Science.gov (United States)

    Yan, Feng; Zhang, Meng; Li, Jinhua

    2014-03-01

    Graphene has attracted much attention in biomedical applications for its fascinating properties. Because of the well-known 2D structure, every atom of graphene is exposed to the environment, so the electronic properties of graphene are very sensitive to charged analytes (ions, DNA, cells, etc.) or an electric field around it, which renders graphene an ideal material for high-performance sensors. Solution-gated graphene transistors (SGGTs) can operate in electrolytes and are thus excellent candidates for chemical and biological sensors, which have been extensively studied in the recent 5 years. Here, the device physics, the sensing mechanisms, and the performance of the recently developed SGGT-based chemical and biological sensors, including pH, ion, cell, bacterial, DNA, protein, glucose sensors, etc., are introduced. Their advantages and shortcomings, in comparison with some conventional techniques, are discussed. Conclusions and challenges for the future development of the field are addressed in the end.

  15. Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors

    Directory of Open Access Journals (Sweden)

    Marie Pospíšilová

    2015-09-01

    Full Text Available This review summarizes principles and current stage of development of fiber-optic chemical sensors (FOCS and biosensors (FOBS. Fiber optic sensor (FOS systems use the ability of optical fibers (OF to guide the light in the spectral range from ultraviolet (UV (180 nm up to middle infrared (IR (10 μm and modulation of guided light by the parameters of the surrounding environment of the OF core. The introduction of OF in the sensor systems has brought advantages such as measurement in flammable and explosive environments, immunity to electrical noises, miniaturization, geometrical flexibility, measurement of small sample volumes, remote sensing in inaccessible sites or harsh environments and multi-sensing. The review comprises briefly the theory of OF elaborated for sensors, techniques of fabrications and analytical results reached with fiber-optic chemical and biological sensors.

  16. Molecularly Imprinted Polymer/Metal Organic Framework Based Chemical Sensors

    Directory of Open Access Journals (Sweden)

    Zhenzhong Guo

    2016-10-01

    Full Text Available The present review describes recent advances in the concept of molecular imprinting using metal organic frameworks (MOF for development of chemical sensors. Two main strategies regarding the fabrication, performance and applications of recent sensors based on molecularly imprinted polymers associated with MOF are presented: molecularly imprinted MOF films and molecularly imprinted core-shell nanoparticles using MOF as core. The associated transduction modes are also discussed. A brief conclusion and future expectations are described herein.

  17. Molecularly Imprinted Polymer/Metal Organic Framework Based Chemical Sensors

    OpenAIRE

    Zhenzhong Guo; Anca Florea; Mengjuan Jiang; Yong Mei; Weiying Zhang; Aidong Zhang; Robert Săndulescu; Nicole Jaffrezic-Renault

    2016-01-01

    The present review describes recent advances in the concept of molecular imprinting using metal organic frameworks (MOF) for development of chemical sensors. Two main strategies regarding the fabrication, performance and applications of recent sensors based on molecularly imprinted polymers associated with MOF are presented: molecularly imprinted MOF films and molecularly imprinted core-shell nanoparticles using MOF as core. The associated transduction modes are also discussed. A brief conclu...

  18. Fault Diagnosis Based on Chemical Sensor Data with an Active Deep Neural Network.

    Science.gov (United States)

    Jiang, Peng; Hu, Zhixin; Liu, Jun; Yu, Shanen; Wu, Feng

    2016-10-13

    Big sensor data provide significant potential for chemical fault diagnosis, which involves the baseline values of security, stability and reliability in chemical processes. A deep neural network (DNN) with novel active learning for inducing chemical fault diagnosis is presented in this study. It is a method using large amount of chemical sensor data, which is a combination of deep learning and active learning criterion to target the difficulty of consecutive fault diagnosis. DNN with deep architectures, instead of shallow ones, could be developed through deep learning to learn a suitable feature representation from raw sensor data in an unsupervised manner using stacked denoising auto-encoder (SDAE) and work through a layer-by-layer successive learning process. The features are added to the top Softmax regression layer to construct the discriminative fault characteristics for diagnosis in a supervised manner. Considering the expensive and time consuming labeling of sensor data in chemical applications, in contrast to the available methods, we employ a novel active learning criterion for the particularity of chemical processes, which is a combination of Best vs. Second Best criterion (BvSB) and a Lowest False Positive criterion (LFP), for further fine-tuning of diagnosis model in an active manner rather than passive manner. That is, we allow models to rank the most informative sensor data to be labeled for updating the DNN parameters during the interaction phase. The effectiveness of the proposed method is validated in two well-known industrial datasets. Results indicate that the proposed method can obtain superior diagnosis accuracy and provide significant performance improvement in accuracy and false positive rate with less labeled chemical sensor data by further active learning compared with existing methods.

  19. Fault Diagnosis Based on Chemical Sensor Data with an Active Deep Neural Network

    Directory of Open Access Journals (Sweden)

    Peng Jiang

    2016-10-01

    Full Text Available Big sensor data provide significant potential for chemical fault diagnosis, which involves the baseline values of security, stability and reliability in chemical processes. A deep neural network (DNN with novel active learning for inducing chemical fault diagnosis is presented in this study. It is a method using large amount of chemical sensor data, which is a combination of deep learning and active learning criterion to target the difficulty of consecutive fault diagnosis. DNN with deep architectures, instead of shallow ones, could be developed through deep learning to learn a suitable feature representation from raw sensor data in an unsupervised manner using stacked denoising auto-encoder (SDAE and work through a layer-by-layer successive learning process. The features are added to the top Softmax regression layer to construct the discriminative fault characteristics for diagnosis in a supervised manner. Considering the expensive and time consuming labeling of sensor data in chemical applications, in contrast to the available methods, we employ a novel active learning criterion for the particularity of chemical processes, which is a combination of Best vs. Second Best criterion (BvSB and a Lowest False Positive criterion (LFP, for further fine-tuning of diagnosis model in an active manner rather than passive manner. That is, we allow models to rank the most informative sensor data to be labeled for updating the DNN parameters during the interaction phase. The effectiveness of the proposed method is validated in two well-known industrial datasets. Results indicate that the proposed method can obtain superior diagnosis accuracy and provide significant performance improvement in accuracy and false positive rate with less labeled chemical sensor data by further active learning compared with existing methods.

  20. Chemical sensor with oscillating cantilevered probe

    Science.gov (United States)

    Adams, Jesse D

    2013-02-05

    The invention provides a method of detecting a chemical species with an oscillating cantilevered probe. A cantilevered beam is driven into oscillation with a drive mechanism coupled to the cantilevered beam. A free end of the oscillating cantilevered beam is tapped against a mechanical stop coupled to a base end of the cantilevered beam. An amplitude of the oscillating cantilevered beam is measured with a sense mechanism coupled to the cantilevered beam. A treated portion of the cantilevered beam is exposed to the chemical species, wherein the cantilevered beam bends when exposed to the chemical species. A second amplitude of the oscillating cantilevered beam is measured, and the chemical species is determined based on the measured amplitudes.

  1. Chemical sensors based on molecularly modified metallic nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Haick, Hossam [Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion - Israel Institute of Technology, Haifa 32000 (Israel)

    2007-12-07

    This paper presents a concise, although admittedly non-exhaustive, didactic review of some of the main concepts and approaches related to the use of molecularly modified metal nanoparticles in or as chemical sensors. This paper attempts to pull together different views and terminologies used in sensors based on molecularly modified metal nanoparticles, including those established upon electrochemical, optical, surface Plasmon resonance, piezoelectric and electrical transduction approaches. Finally, this paper discusses briefly the main advantages and disadvantages of each of the presented class of sensors. (review article)

  2. The Application of Metal Oxide Nanomaterials for Chemical Sensor Development

    Science.gov (United States)

    Xu, Jennifer C.; Hunter, Gary W.; Evans, Laura J.; VanderWal, Randy L.; Berger, Gordon M.

    2007-01-01

    NASA Glenn Research Center (GRC) has been developing miniature chemical sensors for a variety of applications including fire detection, emissions monitoring, fuel leak detection, and environmental monitoring. Smart Lick and Stick sensor technology which integrates a sensor array, electronics, telemetry, and power into one microsystem are being developed. These microsystems require low power consumption for long-term aerospace applications. One approach to decreasing power consumption is the use of nanotechnology. Nanocrystalline tin oxide (SnO2) carbon monoxide (CO) sensors developed previously by this group have been successfully used for fire detection and emissions monitoring. This presentation will briefly review the overall NASA GRC chemical sensor program and discuss our further effort in nanotechnology applications. New carbon dioxide (CO2) sensing material using doped nanocrystalline SnO2 will be discussed. Nanocrystalline SnO2 coated solid electrolyte CO2 sensors and SnO2 nanorod and nanofiber hydrogen (H2) sensors operated at reduced or room temperatures will also be discussed.

  3. Proliferation detection using a remote resonance Raman chemical sensor

    Energy Technology Data Exchange (ETDEWEB)

    Sedlacek, A.J.; Chen, C.L.; Dougherty, D.R.

    1993-08-01

    The authors discussed the potential of the resonance Raman chemical sensor as a remote sensor that can be used for gases, liquids or solids. This spectroscopy has the fundamental advantage that it is based on optical fingerprints that are insensitive to environmental perturbations or excitation frequency. By taking advantage of resonance enhancement, the inelastic scattering cross-section can increase anywhere from 4 to 6 orders of magnitude which translates into increased sensing range or lower detection limits. It was also shown that differential cross-sections as small as 10{sup {minus}27} cm{sup 2}/sr do not preclude the use of this technique as being an important component in one`s remote-sensing arsenal. The results obtained in the early 1970s on various pollutants and the more recent work on atmospheric water cast a favorable light on the prospects for the successful development of a resonance Raman remote sensor. Currently, of the 20 CW agent-related {open_quotes}signature{close_quotes} chemicals that the authors have investigated, 18 show enhancements ranging from 3 to 6 orders of magnitude. The absolute magnitudes of the measured resonance enhanced Raman cross-sections for these 18 chemicals suggest that detection and identification of trace quantities of the {open_quotes}signature{close_quotes} chemicals, through a remote resonance Raman chemical sensor, could be achieved.

  4. Silicon nanowire field-effect chemical sensor

    NARCIS (Netherlands)

    Chen, Songyue

    2011-01-01

    This thesis describes the work that has been done on the project “Design and optimization of silicon nanowire for chemical sensing”, including Si-NW fabrication, electrical/electrochemical modeling, the application as ISFET, and the build-up of Si- NW/LOC system for automatic sample delivery. A nove

  5. Wearable Sensors for Chemical & Biological Detection

    Energy Technology Data Exchange (ETDEWEB)

    Ozanich, Richard M.

    2017-08-31

    One of PNNL’s strengths is the ability to conduct comprehensive technology foraging and objective assessments of various technology areas. The following examples highlight leading research by others in the area of chemical and biological (chem/bio) detection that could be further developed into a robust, highly integrated wearables to aid preparedness, response and recovery.

  6. Magnetically guiding and orienting integrated chemical sensors

    Energy Technology Data Exchange (ETDEWEB)

    Anker, Jeffrey N., E-mail: janker@clemson.edu [Department of Chemistry and Center for Optical Materials Research and Engineering Technology (COMSET), Clemson University, Clemson, SC 29634 (United States); Lee, Yong-Eun Koo; Kopelman, Raoul [Department of Chemistry, University of Michigan, Ann Arbor, MI 48109-1055 (United States)

    2014-08-01

    Fluorescent microsensors for detecting pH and oxygen were positioned and oriented using magnetic tweezers. These multifunctional integrated microsensors were fabricated by physically linking together nano-components including magnetic nanoparticles, fluorescent nanoparticles, and metal hemisphere-shells. Two such microsensors are magnetic roll-shaped polystyrene particles with 120 nm fluorescent oxygen-sensing ormosil nanospheres that are physically pressed (“breaded”) into the roll surface, and 4–5 µm fluorescent microspheres that are capped with a 50 nm thick metal hemispherical shell. The magnetic tweezers consisted of an iron wire that was magnetized in an external magnetic field. Rotating this external field oriented and rotated the microsensors. - Highlights: • Multifunctional microsensors were fabricated by physically linking together nano-components. • Magnetic oxygen microsensors were fabricated with ratiometric fluorescence peaks. • Single sensors were rotated and translated using magnetic tweezers.

  7. Small, Inexpensive Combined NOx and O2 Sensor

    Energy Technology Data Exchange (ETDEWEB)

    W. Lawless; C. Clark

    2008-09-01

    It has been successfully demonstrated in this program that a zirconia multilayer structure with rhodium-based porous electrodes performs well as an amperometric NO{sub x} sensor. The sensitivity of the sensor bodies operating at 650 to 700 C is large, with demonstrated current outputs of 14 mA at 500 ppm NO{sub x} from sensors with 30 layers. The sensor bodies are small (4.5 x 4.2 x 3.1 mm), rugged, and inexpensive. It is projected the sensor bodies will cost $5-$10 in production. This program has built on another successful development program for an oxygen sensor based on the same principles and sponsored by DOE. This oxygen sensor is not sensitive to NO{sub x}. A significant technical hurdle has been identified and solved. It was found that the 100% Rh electrodes oxidize rapidly at the preferred operating temperatures of 650-700 C, and this oxidation is accompanied by a volume change which delaminates the sensors. The problem was solved by using alloys of Rh and Pt. It was found that a 10%/90% Rh/Pt alloy dropped the oxidation rate of the electrodes by orders of magnitude without degrading the NO{sub x} sensitivity of the sensors, allowing long-term stable operation at the preferred operating temperatures. Degradation in the sensor output caused by temperature cycling was identified as a change in resistance at the junction between the sensor body and the external leads attached to the sensor body. The degradation was eliminated by providing strong mechanical anchors for the wire and processing the junctions to obtain good electrical bonds. The NO{sub x} sensors also detect oxygen and therefore the fully-packaged sensor needs to be enclosed with an oxygen sensor in a small, heated zirconia chamber exposed to test gas through a diffusion plug which limits the flow of gas from the outside. Oxygen is pumped from the interior of the chamber to lower the oxygen content and the combination of measurements from the NO{sub x} and oxygen sensors yields the NO{sub x

  8. Chemical sensor network for pH monitoring

    Directory of Open Access Journals (Sweden)

    Claudia Manjarrés

    2016-02-01

    Full Text Available Monitoring of water sources is a major concern worldwide. Wireless sensor networks (WSN may be used for this monitoring. However, current systems employ mainly physical sensors for variables such as temperature, pressure, humidity and light. Wireless chemical sensors networks (WCSNs for environmental monitoring are scarce due to the lack of autonomy of conventional sensors. This paper presents results of a WCSN for monitoring pH based on ion selective field effect transistors (ISFETs. Sensing nodes employ a human interface required for in situ calibration of chemical sensors. Unlike most studies, our work evaluates the network employing chemical measurements and wireless network metrics. Results show zero packet losses by using a time division multiple access (TDMA protocol. The network allows wireless communication within 300 m including attenuation from buildings and trees. Therefore, the system presented in this paper is suitable for long range applications with unobstructed line of sight. pH measurements present a standard deviation below 1%, showing high repeatability. When compared to a commercial pH meter, difference in measurements is below 5%. As a consequence, accuracy is adequate for the application. Measurements also presented high stability during 3 h of continuous measurement.

  9. Novel glucose fiber sensor combining ThFBG with GOD

    Science.gov (United States)

    Li, Mengmeng; Zhou, Ciming; Fan, Dian; Ou, Yiwen

    2016-10-01

    We propose a novel glucose fiber optic sensor combining a thinned cladding fiber Bragg grating (ThFBG) with glucose oxidase (GOD). By immobilizing GOD on the surface of a ThFBG, the fabricated sensor can obtain a high specificity to glucose. Because of the evanescent field, the sensor is very sensitive to the ambient refractive index change arising from the catalytic reaction between glucose and GOD. A four-level fiber model was simulated and verified the precision of the sensing principle. Two methods, glutaraldehyde crosslinking method (GCM) and 3-aminopropyl triethoxysilane covalent coupling method (ATCCM), were experimentally utilized to immobilize GOD. And sensor fabricated with the method ATCCM shows a measurement range of 0-0.82 mg/mL which is better than the sensor fabricated with the method GCM with measurement range of 0-0.67 mg/mL under the same condition. By using ATCCM to immobilize GOD with different concentrations, three sensors were fabricated and used for glucose measurement by monitoring the Bragg wavelength (λb) shifts, the results indicate a good linear relationship between wavelength shift and glucose concentration within a specific range, and the measurement range increases as GOD concentration increases. The highest sensitivity of sensor reaches up to 0.0549 nm/(mg.mL-1). The proposed sensor has distinct advantages in sensing structure, cost and specificity.

  10. MEMS device for mass market gas and chemical sensors

    Science.gov (United States)

    Kinkade, Brian R.; Daly, James T.; Johnson, Edward A.

    2000-08-01

    Gas and chemical sensors are used in many applications. Industrial health and safety monitors allow companies to meet OSHA requirements by detecting harmful levels of toxic or combustible gases. Vehicle emissions are tested during annual inspections. Blood alcohol breathalizers are used by law enforcement. Refrigerant leak detection ensures that the Earth's ozone layer is not being compromised. Industrial combustion emissions are also monitored to minimize pollution. Heating and ventilation systems watch for high levels of carbon dioxide (CO2) to trigger an increase in fresh air exchange. Carbon monoxide detectors are used in homes to prevent poisoning from poor combustion ventilation. Anesthesia gases are monitored during a patients operation. The current economic reality is that two groups of gas sensor technologies are competing in two distinct existing market segments - affordable (less reliable) chemical reaction sensors for consumer markets and reliable (expensive) infrared (IR) spectroscopic sensors for industrial, laboratory, and medical instrumentation markets. Presently high volume mass-market applications are limited to CO detectros and on-board automotive emissions sensors. Due to reliability problems with electrochemical sensor-based CO detectors there is a hesitancy to apply these sensors in other high volume applications. Applications such as: natural gas leak detection, non-invasive blood glucose monitoring, home indoor air quality, personal/portable air quality monitors, home fire/burnt cooking detector, and home food spoilage detectors need a sensor that is a small, efficient, accurate, sensitive, reliable, and inexpensive. Connecting an array of these next generation gas sensors to wireless networks that are starting to proliferate today creates many other applications. Asthmatics could preview the air quality of their destinations as they venture out into the day. HVAC systems could determine if fresh air intake was actually better than the air

  11. Design Of Piezoelectric Microcantilever Chemical Sensors In COMSOL Multiphysics Area

    Directory of Open Access Journals (Sweden)

    Maziar Norouzi

    2009-05-01

    Full Text Available This paper offers an analytical modeling ofthin-filmed, multi-layer piezoelectric microcantileversthat are used as MEMS sensors. These sensors arechemical kind and use piezoelectric microcantilever.These types of microcantilevers are covered withvariety of unique probe coating. The sensor has highsensitivity with external voltage measured in mV anduses PSD1 system to indentify chemical ingredients ofmaterials. The identification of the chemical ingredientof materials is based on change in angle of microcantilever in the liquid or gas environment. Thedeflection of microcantilever results in varying voltagethat can be used to analyze materials. Analyticalsimulation using Cosmol software and theoreticalcomputations using equations will be offered in orderto determine the parameters for optimal design setting.The analytical simulation includes design of mems andCosmol software model development. The analyticalmodel of the cantilever will be analyzed and theprocess of its construction will be discussed.

  12. Chemical Sensors Based on Molecularly Imprinted Sol-Gel Materials

    Directory of Open Access Journals (Sweden)

    Franz L. Dickert

    2010-03-01

    Full Text Available The sol-gel technique is earning the worldwide attention of researchers in the field of material science, due to its versatility in synthesizing inorganic ceramic materials at mild conditions. High purity, homogeneity, controlled porosity, stable temperature and nanoscale structuring are the most remarkable features offered by this method for generating highly sensitive and selective matrices to incorporate analyte molecules. The crafting of sol-gel sensors through molecular imprinting has put great influence on the development of innovative chemical sensors, which can be seen from the growing number of publications in this field. The review provides a brief overview of sol-gel sensor applications, and discusses the contribution of molecular imprinting in exploring the new world of sensors.

  13. Waveguide Zeeman interferometry for thin-film chemical sensors

    Energy Technology Data Exchange (ETDEWEB)

    Grace, K.M.; Shrouf, K.; Johnston, R.G.; Yang, X.; Swanson, B. [Los Alamos National Lab., NM (United States); Honkanen, S.; Ayras, P.; Peyghambarian, N. [Optical Sciences Center, Univ. of Arizona, Tucson, AZ (United States); Katila, P.; Leppihalme, M. [VTT Electronics (Finland)

    1997-10-01

    A chemical sensor is demonstrated which is based on Si{sub 3}N{sub 4} optical waveguides coated with species-selective thin films and using Zeeman interferometry as the detection technique. Relative phase change between TE and TM modes is measured. Real time and reversible response to toluene is shown with ppm level sensitivity.

  14. Supramolecular Derivation of Graphene Nanomaterials for Chemical Sensors

    DEFF Research Database (Denmark)

    Olsen, Gunnar

    With properties such as high surface area, high conductivity, and low production cost with easy up-scaling, graphene-like materials provide a promising support for many applications, one of which is for chemical sensors. By functionalization with molecular receptors such as supramolecular moietie...

  15. Durable chemical sensors based on field-effect transistors

    NARCIS (Netherlands)

    Reinhoudt, D.N.

    1995-01-01

    The design of durable chemical sensors based on field-effect transistors (FETs) is described. After modification of an ion-sensitive FET (ISFET) with a polysiloxane membrane matrix, it is possible to attach all electroactive components covalently. Preliminary results of measurements with a sodium-se

  16. Field-effect-based multifunctional hybrid sensor module for the determination of both (bio-)chemical and physical parameters

    Science.gov (United States)

    Schoening, Michael J.; Poghossian, Arshak; Schultze, J. Walter; Lueth, Hans

    2002-02-01

    Sensor systems for multi-parameter detection in fluidics usually combine different sensors, which are designed to detect either a physical or (bio-)chemical parameter. Therefore, such systems include a more complicated fabrication technology and measuring set-up. In this work, an ISFET (ion-sensitive field-effect transistor), which is well known as a (bio-)chemical sensor, is utilized as transducer for the detection of both (bio-)chemical and physical parameters. A multifunctional hybrid module for the determination of two (bio-)chemical parameters (pH, penicillin concentration) and three physical parameters (temperature, flow velocity and flow direction) using only two sensor structures, an ion generator and a reference electrode, is realized and its performance has been investigated. Here, a multifunctionality of the sensor system is achieved by means of different sensor arrangements and/or different operation modes. A Ta2O5-gate ISFET was used as transducer for all sensors. A novel time-of-flight type ISFET-based flow-velocity (flow rate) and flow-direction sensor using in-situ electrochemical generation of chemical tracers is presented. Due to the fast response of the ISFET (usually in the millisecond range), an ISFET-based flow sensor is suitable for the measurement of the flow velocity in a wide range. With regard to practical applications, pH measurements with this ISFET were performed in rain droplets.

  17. Chemical gas sensors for car exhaust and cabin air monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kalman, E.-L.; Winquist, F. [Department of Physics and Measurement Technology, Laboratory of Applied Physics, Linkoeping University, Gothenburg (Sweden); Rudell, B. [Department of Occupational and Environmental Medicine, Centre of Public Health Sciences, Linkoeping, Gothenburg (Sweden); Loefvendahl, A. [Volvo Car Corporation, Gothenburg (Sweden); Wass, U. [Volvo Technological Development Corporation, Gothenburg (Sweden)

    2002-07-01

    A combination of charcoal and particle filters has previously been shown to reduce effectively the smell of diesel exhaust. In this paper it is shown that the smell of diesel exhaust can successfully be predicted by the concentration of total volatile organic compounds and the concentration of certain carbonyl compounds. Projection to latent structures was utilised for model building. An electronic nose consisting of MOFSET and MOS sensors could less successfully predict the smell, but identified the same filter combination as being most efficient. The car cabin during urban driving was also monitored, both by the means of MOFSET sensors and by chemiluminescence. The pollution level inside the car is shown to be elevated by about 30% compared to outside the car. A combination filter together with an air inlet sensor switch is shown to reduce the NO{sub x} levels inside te car by 30% compared to outside, with the ability to significantly decrease the peak levels. (author)

  18. Odour Detection Methods: Olfactometry and Chemical Sensors

    Directory of Open Access Journals (Sweden)

    Sara Lovascio

    2011-05-01

    Full Text Available The complexity of the odours issue arises from the sensory nature of smell. From the evolutionary point of view olfaction is one of the oldest senses, allowing for seeking food, recognizing danger or communication: human olfaction is a protective sense as it allows the detection of potential illnesses or infections by taking into account the odour pleasantness/unpleasantness. Odours are mixtures of light and small molecules that, coming in contact with various human sensory systems, also at very low concentrations in the inhaled air, are able to stimulate an anatomical response: the experienced perception is the odour. Odour assessment is a key point in some industrial production processes (i.e., food, beverages, etc. and it is acquiring steady importance in unusual technological fields (i.e., indoor air quality; this issue mainly concerns the environmental impact of various industrial activities (i.e., tanneries, refineries, slaughterhouses, distilleries, civil and industrial wastewater treatment plants, landfills and composting plants as sources of olfactory nuisances, the top air pollution complaint. Although the human olfactory system is still regarded as the most important and effective “analytical instrument” for odour evaluation, the demand for more objective analytical methods, along with the discovery of materials with chemo-electronic properties, has boosted the development of sensor-based machine olfaction potentially imitating the biological system. This review examines the state of the art of both human and instrumental sensing currently used for the detection of odours. The olfactometric techniques employing a panel of trained experts are discussed and the strong and weak points of odour assessment through human detection are highlighted. The main features and the working principles of modern electronic noses (E-Noses are then described, focusing on their better performances for environmental analysis. Odour emission monitoring

  19. IN-LINE CHEMICAL SENSOR DEPLOYMENT IN A TRITIUM PLANT

    Energy Technology Data Exchange (ETDEWEB)

    Tovo, L.; Wright, J.; Torres, R.; Peters, B.

    2013-10-02

    The Savannah River Tritium Plant (TP) relies on well understood but aging sensor technology for process gas analysis. Though new sensor technologies have been brought to various readiness levels, the TP has been reluctant to install technologies that have not been tested in tritium service. This gap between sensor technology development and incorporating new technologies into practical applications demonstrates fundamental challenges that exist when transitioning from status quo to state-of-the-art in an extreme environment such as a tritium plant. These challenges stem from three root obstacles: 1) The need for a comprehensive assessment of process sensing needs and requirements; 2) The lack of a pick-list of process-compatible sensor technologies; and 3) The need to test technologies in a tritium-contaminated process environment without risking production. At Savannah River, these issues are being addressed in a two phase project. In the first phase, TP sensing requirements were determined by a team of process experts. Meanwhile, Savannah River National Laboratory sensor experts identified candidate technologies and related them to the TP processing requirements. The resulting roadmap links the candidate technologies to actual plant needs. To provide accurate assessments of how a candidate sensor technology would perform in a contaminated process environment, an instrument demonstration station was established within a TP glove box. This station was fabricated to TP process requirements and designed to handle high activity samples. The combination of roadmap and demonstration station provides the following assets: Creates a partnership between the process engineers and researchers for sensor selection, maturation, and insertion, Selects the right sensors for process conditions Provides a means for safely inserting new sensor technology into the process without risking production, and Provides a means to evaluate off normal occurrences where and when they occur

  20. Nanostructured conjugated polymers in chemical sensors: synthesis, properties and applications.

    Science.gov (United States)

    Correa, D S; Medeiros, E S; Oliveira, J E; Paterno, L G; Mattoso, Luiz C

    2014-09-01

    Conjugated polymers are organic materials endowed with a π-electron conjugation along the polymer backbone that present appealing electrical and optical properties for technological applications. By using conjugated polymeric materials in the nanoscale, such properties can be further enhanced. In addition, the use of nanostructured materials makes possible miniaturize devices at the micro/nano scale. The applications of conjugated nanostructured polymers include sensors, actuators, flexible displays, discrete electronic devices, and smart fabric, to name a few. In particular, the use of conjugated polymers in chemical and biological sensors is made feasible owning to their sensitivity to the physicochemical conditions of its surrounding environment, such as chemical composition, pH, dielectric constant, humidity or even temperature. Subtle changes in these conditions bring about variations on the electrical (resistivity and capacitance), optical (absorptivity, luminescence, etc.), and mechanical properties of the conjugated polymer, which can be precisely measured by different experimental methods and ultimately associated with a specific analyte and its concentration. The present review article highlights the main features of conjugated polymers that make them suitable for chemical sensors. An especial emphasis is given to nanostructured sensors systems, which present high sensitivity and selectivity, and find application in beverage and food quality control, pharmaceutical industries, medical diagnosis, environmental monitoring, and homeland security, and other applications as discussed throughout this review.

  1. Semiconductor Quantum Dots in Chemical Sensors and Biosensors

    Directory of Open Access Journals (Sweden)

    Nikos Chaniotakis

    2009-09-01

    Full Text Available Quantum dots are nanometre-scale semiconductor crystals with unique optical properties that are advantageous for the development of novel chemical sensors and biosensors. The surface chemistry of luminescent quantum dots has encouraged the development of multiple probes based on linked recognition molecules such as peptides, nucleic acids or small-molecule ligands. This review overviews the design of sensitive and selective nanoprobes, ranging from the type of target molecules to the optical transduction scheme. Representative examples of quantum dot-based optical sensors from this fast-moving field have been selected and are discussed towards the most promising directions for future research.

  2. Development of combined Opto-Acoustical sensor Modules

    Energy Technology Data Exchange (ETDEWEB)

    Enzenhoefer, A., E-mail: alexander.enzenhoefer@physik.uni-erlangen.de [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Erlangen Centre for Astroparticle Physics, Erwin-Rommel-Str. 1, D-91058 Erlangen (Germany); Anton, G.; Graf, K.; Hoessl, J.; Katz, U.; Lahmann, R.; Neff, M.; Richardt, C. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Erlangen Centre for Astroparticle Physics, Erwin-Rommel-Str. 1, D-91058 Erlangen (Germany)

    2012-01-11

    The faint fluxes of cosmic neutrinos expected at very high energies require large instrumented detector volumes. The necessary volumes in combination with a sufficient shielding against background constitute forbidding and complex environments (e.g. the deep sea) as sites for neutrino telescopes. To withstand these environments and to assure the data quality, the sensors have to be reliable and their operation has to be as simple as possible. A compact sensor module design including all necessary components for data acquisition and module calibration would simplify the detector mechanics and ensures the long term operability of the detector. The compact design discussed here combines optical and acoustical sensors inside one module, therefore reducing electronics and additional external instruments for calibration purposes. In this design the acoustical sensor is primary used for acoustic positioning of the module. The module may also be used for acoustic particle detection and marine science if an appropriate acoustical sensor is chosen. First tests of this design are promising concerning the task of calibration. To expand the field of application also towards acoustic particle detection further improvements concerning electromagnetic shielding and adaptation of the single components are necessary.

  3. Optimal Layout of Sensors on Wind Turbine Blade Based on Combinational Algorithm

    National Research Council Canada - National Science Library

    Gu, Guimei; Zhao, Yu; Zhang, Xin

    2016-01-01

    This work proposes a comprehensive combinational algorithm for sensor layout to solve the problem that unreasonable sensor layout affects the effectiveness of data selection and reduces the accuracy...

  4. Heat-activated Plasmonic Chemical Sensors for Harsh Environments

    Energy Technology Data Exchange (ETDEWEB)

    Carpenter, Michael [SUNY Polytechnic Inst., Albany, NY (United States); Oh, Sang-Hyun [Univ. of Minnesota, Minneapolis, MN (United States)

    2015-12-01

    A passive plasmonics based chemical sensing system to be used in harsh operating environments was investigated and developed within this program. The initial proposed technology was based on combining technologies developed at the SUNY Polytechnic Institute Colleges of Nanoscale Science and Engineering (CNSE) and at the University of Minnesota (UM). Specifically, a passive wireless technique developed at UM was to utilize a heat-activated plasmonic design to passively harvest the thermal energy from within a combustion emission stream and convert this into a narrowly focused light source. This plasmonic device was based on a bullseye design patterned into a gold film using focused ion beam methods (FIB). Critical to the design was the use of thermal stabilizing under and overlayers surrounding the gold film. These stabilizing layers were based on both atomic layer deposited films as well as metal laminate layers developed by United Technologies Aerospace Systems (UTAS). While the bullseye design was never able to be thermally stabilized for operating temperatures of 500oC or higher, an alternative energy harvesting design was developed by CNSE within this program. With this new development, plasmonic sensing results are presented where thermal energy is harvested using lithographically patterned Au nanorods, replacing the need for an external incident light source. Gas sensing results using the harvested thermal energy are in good agreement with sensing experiments, which used an external incident light source. Principal Component Analysis (PCA) was used to reduce the wavelength parameter space from 665 variables down to 4 variables with similar levels of demonstrated selectivity. The method was further improved by patterning rods which harvested energy in the near infrared, which led to a factor of 10 decrease in data acquisition times as well as demonstrated selectivity with a reduced wavelength data set. The combination of a plasmonic-based energy harvesting

  5. Direct-Dispense Polymeric Waveguides Platform for Optical Chemical Sensors

    Directory of Open Access Journals (Sweden)

    Mohamad Hajj-Hassan

    2008-12-01

    Full Text Available We describe an automated robotic technique called direct-dispense to fabricate a polymeric platform that supports optical sensor arrays. Direct-dispense, which is a type of the emerging direct-write microfabrication techniques, uses fugitive organic inks in combination with cross-linkable polymers to create microfluidic channels and other microstructures. Specifically, we describe an application of direct-dispensing to develop optical biochemical sensors by fabricating planar ridge waveguides that support sol-gelderived xerogel-based thin films. The xerogel-based sensor materials act as host media to house luminophore biochemical recognition elements. As a prototype implementation, we demonstrate gaseous oxygen (O2 responsive optical sensors that operate on the basis of monitoring luminescence intensity signals. The optical sensor employs a Light Emitting Diode (LED excitation source and a standard silicon photodiode as the detector. The sensor operates over the full scale (0%-100% of O2 concentrations with a response time of less than 1 second. This work has implications for the development of miniaturized multisensor platforms that can be cost-effectively and reliably mass-produced.

  6. Photonic crystal fiber based chloride chemical sensors for corrosion monitoring

    Science.gov (United States)

    Wei, Heming; Tao, Chuanyi; Krishnaswamy, Sridhar

    2016-04-01

    Corrosion of steel is one of the most important durability issues in reinforced concrete (RC) structures because aggressive ions such as chloride ions permeate concrete and corrode steel, consequently accelerating the destruction of structures, especially in marine environments. There are many practical methods for corrosion monitoring in RC structures, mostly focusing on electrochemical-based sensors for monitoring the chloride ion which is thought as one of the most important factors resulting in steel corrosion. In this work, we report a fiber-optic chloride chemical sensor based on long period gratings inscribed in a photonic crystal fiber (PCF) with a chloride sensitive thin film. Numerical simulation is performed to determine the characteristics and resonance spectral response versus the refractive indices of the analyte solution flowing through into the holes in the PCF. The effective refractive index of the cladding mode of the LPGs changes with variations of the analyte solution concentration, resulting in a shift of the resonance wavelength, hence providing the sensor signal. This fiber-optic chemical sensor has a fast response, is easy to prepare and is not susceptible to electromagnetic environment, and can therefore be of use for structural health monitoring of RC structures subjected to such aggressive environments.

  7. Semiconductor Quantum Dots in Chemical Sensors and Biosensors

    OpenAIRE

    Nikos Chaniotakis; Frasco, Manuela F.

    2009-01-01

    Quantum dots are nanometre-scale semiconductor crystals with unique optical properties that are advantageous for the development of novel chemical sensors and biosensors. The surface chemistry of luminescent quantum dots has encouraged the development of multiple probes based on linked recognition molecules such as peptides, nucleic acids or small-molecule ligands. This review overviews the design of sensitive and selective nanoprobes, ranging from the type of target molecules to the optical ...

  8. Wireless Chemical Sensor and Sensing Method for Use Therewith

    Science.gov (United States)

    Woodard, Stanley E. (Inventor); Oglesby, Donald M. (Inventor); Taylor, Bryant D. (Inventor)

    2016-01-01

    A wireless chemical sensor includes an electrical conductor and a material separated therefrom by an electric insulator. The electrical conductor is an unconnected open-circuit shaped for storage of an electric field and a magnetic field. In the presence of a time-varying magnetic field, the first electrical conductor resonates to generate harmonic electric and magnetic field responses. The material is positioned at a location lying within at least one of the electric and magnetic field responses so-generated. The material changes in electrical conductivity in the presence of a chemical-of-interest.

  9. Speaker verification using combined acoustic and EM sensor signal processing

    Energy Technology Data Exchange (ETDEWEB)

    Ng, L C; Gable, T J; Holzrichter, J F

    2000-11-10

    Low Power EM radar-like sensors have made it possible to measure properties of the human speech production system in real-time, without acoustic interference. This greatly enhances the quality and quantity of information for many speech related applications. See Holzrichter, Burnett, Ng, and Lea, J. Acoustic. SOC. Am . 103 ( 1) 622 (1998). By combining the Glottal-EM-Sensor (GEMS) with the Acoustic-signals, we've demonstrated an almost 10 fold reduction in error rates from a speaker verification system experiment under a moderate noisy environment (-10dB).

  10. Detection in urban scenario using combined airborne imaging sensors

    Science.gov (United States)

    Renhorn, Ingmar; Axelsson, Maria; Benoist, Koen; Bourghys, Dirk; Boucher, Yannick; Briottet, Xavier; De Ceglie, Sergio; Dekker, Rob; Dimmeler, Alwin; Dost, Remco; Friman, Ola; Kåsen, Ingebjørg; Maerker, Jochen; van Persie, Mark; Resta, Salvatore; Schwering, Piet; Shimoni, Michal; Haavardsholm, Trym Vegard

    2012-06-01

    The EDA project "Detection in Urban scenario using Combined Airborne imaging Sensors" (DUCAS) is in progress. The aim of the project is to investigate the potential benefit of combined high spatial and spectral resolution airborne imagery for several defense applications in the urban area. The project is taking advantage of the combined resources from 7 contributing nations within the EDA framework. An extensive field trial has been carried out in the city of Zeebrugge at the Belgian coast in June 2011. The Belgian armed forces contributed with platforms, weapons, personnel (soldiers) and logistics for the trial. Ground truth measurements with respect to geometrical characteristics, optical material properties and weather conditions were obtained in addition to hyperspectral, multispectral and high resolution spatial imagery. High spectral/spatial resolution sensor data are used for detection, classification, identification and tracking.

  11. In Situ Sensors for the Chemical Industry- Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Tate, J D; Knittel, Trevor

    2006-06-30

    minimized their applicability in the chemical industry. In order to take advantage of the promise of this technology a number of technology advances were required, within price limits for market acceptance. This project significantly advanced the state of TDL technology for application in chemical industry applications. With these advances a commercially available product now exists that has already achieved market success and is installed in critical applications. The ability to make fast, sensitive and accurate measurements inside the chemical processes is now delivering improved process control, energy efficiency and emissions control within the U.S. Chemical Industry. Despite the success we enjoyed for the laser-based sensors, there were significant technical barriers for the solid-state sensors. With exception of a generic close-coupled extractive housing and electronics interface, there were significant issues with all of the solid-state sensor devices we sought to develop and test. Ultimately, these issues were roadblocks that prevented further development and testing. The fundamental limitations of available sensor materials that we identified, formulated and tested were overwhelming. This situation forced our team to cancel these portions of the project and focus our resources on laser-based sensor techniques. The barriers of material compatibility, sensitivity, speed of response, chemical interferences, etc. are surmountable in the field of solid-state sensors. Inability to address any single one of these attributes will prevent wide-implementation into this market. This situation is plainly evident by the lack of such devices in the online analyzer market (for petrochemicals).

  12. Chemometrics review for chemical sensor development, task 7 report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-05-01

    This report, the seventh in a series on the evaluation of several chemical sensors for use in the U.S. Department of Energy`s (DOE`s) site characterization and monitoring programs, concentrates on the potential use of chemometrics techniques in analysis of sensor data. Chemometrics is the chemical discipline that uses mathematical, statistical, and other methods that employ formal logic to: design or select optimal measurement procedures and experiments and provide maximum relevant chemical information by analyzing chemical data. The report emphasizes the latter aspect. In a formal sense, two distinct phases are in chemometrics applications to analytical chemistry problems: (1) the exploratory data analysis phase and (2) the calibration and prediction phase. For use in real-world problems, it is wise to add a third aspect - the independent validation and verification phase. In practical applications, such as the ERWM work, and in order of decreasing difficulties, the most difficult tasks in chemometrics are: establishing the necessary infrastructure (to manage sampling records, data handling, and data storage and related aspects), exploring data analysis, and solving calibration problems, especially for nonlinear models. Chemometrics techniques are different for what are called zeroth-, first-, and second-order systems, and the details depend on the form of the assumed functional relationship between the measured response and the concentrations of components in mixtures. In general, linear relationships can be handled relatively easily, but nonlinear relationships can be difficult.

  13. Soil chemical sensor and precision agricultural chemical delivery system and method

    Energy Technology Data Exchange (ETDEWEB)

    Colburn, J.W. Jr.

    1991-07-23

    A real time soil chemical sensor and precision agricultural chemical delivery system includes a plurality of ground-engaging tools in association with individual soil sensors which measure soil chemical levels. The system includes the addition of a solvent which rapidly saturates the soil/tool interface to form a conductive solution of chemicals leached from the soil. A multivalent electrode, positioned within a multivalent frame of the ground-engaging tool, applies a voltage or impresses a current between the electrode and the tool frame. A real-time soil chemical sensor and controller senses the electrochemical reaction resulting from the application of the voltage or current to the leachate, measures it by resistivity methods, and compares it against pre-set resistivity levels for substances leached by the solvent. Still greater precision is obtained by calibrating for the secondary current impressed through solvent-less soil. The appropriate concentration is then found and the servo-controlled delivery system applies the appropriate amount of fertilizer or agricultural chemicals substantially in the location from which the soil measurement was taken. 5 figures.

  14. Pd/CeO2/SiC Chemical Sensors

    Science.gov (United States)

    Lu, Weijie; Collins, W. Eugene

    2005-01-01

    The incorporation of nanostructured interfacial layers of CeO2 has been proposed to enhance the performances of Pd/SiC Schottky diodes used to sense hydrogen and hydrocarbons at high temperatures. If successful, this development could prove beneficial in numerous applications in which there are requirements to sense hydrogen and hydrocarbons at high temperatures: examples include monitoring of exhaust gases from engines and detecting fires. Sensitivity and thermal stability are major considerations affecting the development of high-temperature chemical sensors. In the case of a metal/SiC Schottky diode for a number of metals, the SiC becomes more chemically active in the presence of the thin metal film on the SiC surface at high temperature. This increase in chemical reactivity causes changes in chemical composition and structure of the metal/SiC interface. The practical effect of the changes is to alter the electronic and other properties of the device in such a manner as to degrade its performance as a chemical sensor. To delay or prevent these changes, it is necessary to limit operation to a temperature CeO2 films is based partly on the observation that nanostructured materials in general have potentially useful electrical properties, including an ability to enhance the transfer of electrons. In particular, nanostructured CeO2, that is CeO2 with nanosized grains, has shown promise for incorporation into hightemperature electronic devices. Nanostructured CeO2 films can be formed on SiC and have been shown to exhibit high thermal stability on SiC, characterized by the ability to withstand temperatures somewhat greater than 700 C for limited times. The exchanges of oxygen between CeO2 and SiC prevent the formation of carbon and other chemical species that are unfavorable for operation of a SiC-based Schottky diode as a chemical sensor. Consequently, it is anticipated that in a Pd/CeO2/SiC Schottky diode, the nanostructured interfacial CeO2 layer would contribute to

  15. Chemical, Biological, and Explosive Sensors for Field Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kevin Kyle, Manuel Manard, Stephan Weeks

    2009-01-31

    Special Technologies Laboratory (STL) is developing handheld chemical, biological, and explosive (CBE) detection systems and sensor motes for wireless networked field operations. The CBE sensors are capable of detecting and identifying multiple targeted toxic industrial chemicals (TICs) and high-explosive vapor components. The CBE devices are based on differential mobility spectrometry (DMS) coupled with fast gas chromatography (GC) or mass spectrometry. The systems all include the concepts of: 1. Direct air/particulate “smart” sampling 2. Selective, continuous real-time (~1 sec) alert monitoring using DMS 3. Highly selective, rapid dual technology separation/verification analysis The biosensor technology is based on Raman aerosol particle flow cytometry for target detection and identification. Monitoring and identifying trace level chemical vapors directly from ambient air will allow First Responders to quickly adapt situational response strategies and personal protective equipment needs to the specific response scenario being encountered. First Responders require great confidence in the measurements and ability of a given system to detect CBE below threshold levels without interferences. The concept of determining the background matrix in near real-time to allow subsequent automated field-programmable method selection and cueing of high-value assets in a wide range of environs will be presented. This provides CBE information for decisions prior to First Responders entering the response site or sending a portable mobile unit for a remote site survey of the hazards. The focus is on real-time information needed by those responsible for emergency response and national security.

  16. Nanowire sensors and arrays for chemical/biomolecule detection

    Science.gov (United States)

    Yun, Minhee; Lee, Choonsup; Vasquez, Richard P.; Ramanathan, K.; Bangar, M. A.; Chen, W.; Mulchandan, A.; Myung, N. V.

    2005-01-01

    We report electrochemical growth of single nanowire based sensors using e-beam patterned electrolyte channels, potentially enabling the controlled fabrication of individually addressable high density arrays. The electrodeposition technique results in nanowires with controlled dimensions, positions, alignments, and chemical compositions. Using this technique, we have fabricated single palladium nanowires with diameters ranging between 75 nm and 300 nm and conducting polymer nanowires (polypyrrole and polyaniline) with diameters between 100 nm and 200 nm. Using these single nanowires, we have successfully demonstrated gas sensing with Pd nanowires and pH sensing with polypirrole nanowires.

  17. Graphene Electronic Device Based Biosensors and Chemical Sensors

    Science.gov (United States)

    Jiang, Shan

    Two-dimensional layered materials, such as graphene and MoS2, are emerging as an exciting material system for a new generation of atomically thin electronic devices. With their ultrahigh surface to volume ratio and excellent electrical properties, 2D-layered materials hold the promise for the construction of a generation of chemical and biological sensors with unprecedented sensitivity. In my PhD thesis, I mainly focus on graphene based electronic biosensors and chemical sensors. In the first part of my thesis, I demonstrated the fabrication of graphene nanomesh (GNM), which is a graphene thin film with a periodic array of holes punctuated in it. The periodic holes introduce long periphery active edges that provide a high density of functional groups (e.g. carboxylic groups) to allow for covalent grafting of specific receptor molecules for chemical and biosensor applications. After covalently functionalizing the GNM with glucose oxidase, I managed to make a novel electronic sensor which can detect glucose as well as pH change. In the following part of my thesis I demonstrate the fabrication of graphene-hemin conjugate for nitric oxide detection. The non-covalent functionalization through pi-pi stacking interaction allows reliable immobilization of hemin molecules on graphene without damaging the graphene lattice to ensure the highly sensitive and specific detection of nitric oxide. The graphene-hemin nitric oxide sensor is capable of real-time monitoring of nitric oxide concentrations, which is of central importance for probing the diverse roles of nitric oxide in neurotransmission, cardiovascular systems, and immune responses. Our studies demonstrate that the graphene-hemin sensors can respond rapidly to nitric oxide in physiological environments with sub-nanomolar sensitivity. Furthermore, in vitro studies show that the graphene-hemin sensors can be used for the detection of nitric oxide released from macrophage cells and endothelial cells, demonstrating their

  18. Development of an optical redox chemical sensor for nitrite determination

    Directory of Open Access Journals (Sweden)

    Saadat Rastegarzadeh

    2012-01-01

    Full Text Available An optical chemical sensor for the determination of nitrite based on incorporating methyltrioctylammonium chloride as an anionic exchanger on the triacetylcellulose polymer has been reported. The response of the sensor is based on the redox reaction between nitrite in aqueous solution and iodide adsorbed on sensing membrane using anion exchange phenomena. The sensing membrane reversibly responses to nitrite ion over the range of 6.52×10-6 - 8.70×10-5 mol L-1 with a detection limit of 6.05×10-7 mol L-1 (0.03 µg mL-1 and response time of 6 min. The relative standard deviation for eight replicate measurements of 8.70×10-6 and 4.34×10-5 mol L-1 of nitrite was 4.4 and 2.5 %, respectively. The sensor was successfully applied for determination of nitrite in food, saliva and water samples.

  19. Very Large Chemical Sensor Array for Mimicking Biological Olfaction

    Science.gov (United States)

    Beccherelli, R.; Zampetti, E.; Pantalei, S.; Bernabei, M.; Persaud, K. C.

    2009-05-01

    Olfactory receptor neurons (ORN) in the mammalian olfactory system, transduce molecular properties of the odorants into electrical signals and project these into the olfactory bulb (OB). In the biological system several millions of receptor neurons of a few hundred types create redundancy and the massive convergence of the ORNs to the OB, is thought to enhance the sensitivity and selectivity of the system. To explore this concept, the NEUROCHEM project will build a polymeric chemical sensor array consisting of 216 (65536) sensors with tens of different types. To interface such a large sensor array, a topological array configuration with n rows and m columns, has been adopted, to reduce the total wiring connections to n+m. A method of addressing a single element in the array in isolation of the rest of the network has been developed. Over the array ten different conductive polymers with different sensing characteristics will be deposited by means of electrodeposition and inkjet printing. A smaller prototype of 64 elements has been investigated and the results are here reported and discussed.

  20. Solubility properties of siloxane polymers for chemical sensors

    Energy Technology Data Exchange (ETDEWEB)

    Grate, J.W. [Pacific Northwest Lab., Richland, WA (United States); Abraham, M.H. [University College, London (United Kingdom)

    1995-05-01

    This paper discusses the factors governing the sorption of vapors by organic polymers. The principles have been applied in the past for designing and selecting polymers for acoustic wave sensors; however they apply equally well to sorption of vapors by polymers used on optical chemical sensors. A set of solvation parameters (a table is presented for various organic vapors) have been developed that describe the particular solubility properties of individual solute molecules; they are used in linear solvation energy relationships (LSER) that model the sorption process. LSER coefficients are tabulated for five polysiloxanes; so are individual interaction terms for each of the 5 polymers. Dispersion interactions play a major role in determining overall partition coefficients; the log L{sup 16} (gas-liquid partition coefficient of solute on hexadecane) value of vapors are important in determining overall sorption. For the detection of basic vapors such as organophosphates, a hydrogen-bond acidic polymers will be most effective at sorbing them. Currently, fiber optic sensors are being developed where the cladding serves as a sorbent layer to collect and concentrate analyte vapors, which will be detected and identified spectroscopically. These solubility models will be used to design the polymers for the cladding for particular vapors.

  1. Single walled carbon nanotubes functionally adsorbed to biopolymers for use as chemical sensors

    Science.gov (United States)

    Johnson, Jr., Alan T.; Gelperin, Alan; Staii, Cristian

    2011-07-12

    Chemical field effect sensors comprising nanotube field effect devices having biopolymers such as single stranded DNA functionally adsorbed to the nanotubes are provided. Also included are arrays comprising the sensors and methods of using the devices to detect volatile compounds.

  2. Biologically inspired large scale chemical sensor arrays and embedded data processing

    Science.gov (United States)

    Marco, S.; Gutiérrez-Gálvez, A.; Lansner, A.; Martinez, D.; Rospars, J. P.; Beccherelli, R.; Perera, A.; Pearce, T.; Vershure, P.; Persaud, K.

    2013-05-01

    Biological olfaction outperforms chemical instrumentation in specificity, response time, detection limit, coding capacity, time stability, robustness, size, power consumption, and portability. This biological function provides outstanding performance due, to a large extent, to the unique architecture of the olfactory pathway, which combines a high degree of redundancy, an efficient combinatorial coding along with unmatched chemical information processing mechanisms. The last decade has witnessed important advances in the understanding of the computational primitives underlying the functioning of the olfactory system. EU Funded Project NEUROCHEM (Bio-ICT-FET- 216916) has developed novel computing paradigms and biologically motivated artefacts for chemical sensing taking inspiration from the biological olfactory pathway. To demonstrate this approach, a biomimetic demonstrator has been built featuring a large scale sensor array (65K elements) in conducting polymer technology mimicking the olfactory receptor neuron layer, and abstracted biomimetic algorithms have been implemented in an embedded system that interfaces the chemical sensors. The embedded system integrates computational models of the main anatomic building blocks in the olfactory pathway: the olfactory bulb, and olfactory cortex in vertebrates (alternatively, antennal lobe and mushroom bodies in the insect). For implementation in the embedded processor an abstraction phase has been carried out in which their processing capabilities are captured by algorithmic solutions. Finally, the algorithmic models are tested with an odour robot with navigation capabilities in mixed chemical plumes

  3. Organic/Inorganic Hybrid Nanostructures for Chemical Plasmonic Sensors

    Science.gov (United States)

    Chang, Sehoon

    2011-12-01

    The work presented in this dissertation suggests novel design of chemical plasmonic sensors which have been developed based on Localized Surface Plasmon Resonance (LSPR), and Surface-enhanced Raman scattering (SERS) phenomena. The goal of the study is to understand the SERS phenomena for 3D hybrid (organic/inorganic) templates and to design of the templates for trace-level detection of selected chemical analytes relevant to liquid explosives and hazardous chemicals. The key design criteria for the development of the SERS templates are utilizing selective polymeric nanocoatings within cylindrical nanopores for promoting selective adsorption of chemical analyte molecules, maximizing specific surface area, and optimizing concentration of hot spots with efficient light interaction inside nanochannels. The organic/inorganic hybrid templates are optimized through a comprehensive understanding of the LSPR properties of the gold nanoparticles, gold nanorods, interaction of light with highly porous alumina template, and the choice of physical and chemical attributes of the selective coating. Furthermore, novel method to assemble silver nanoparticles in 3D as the active SERS-active substrate has been demonstrated by uniform, in situ growth of silver nanoparticles from electroless deposited silver seeds excluding any adhesive polymer layer on template. This approach can be the optimal for SERS sensing applications because it is not necessary to separate the Raman bands of the polyelectrolyte binding layer from those of the desired analyte. The fabrication method is an efficient, simple and fast way to assemble nanoparticles into 3D nanostructures. Addressable Raman markers from silver nanowire crossbars with silver nanoparticles are also introduced and studied. Assembly of silver nanowire crossbar structure is achieved by simple, double-step capillary transfer lithography. The on/off SERS properties can be observed on silver nanowire crossbars with silver nanoparticles

  4. Fabrication of SAW Sensor for Detecting Chemical Agent

    Institute of Scientific and Technical Information of China (English)

    J H Lee; B S Joo; J S Huh; D D Lee

    2006-01-01

    SAW sensors using five different types of polymer to detect of chemical agents (DMMP, CH3CN, CH2Cl2, DCP)have been fabricated and its gas response characteristics were extensively investigated. The polymers used as the sensing material are polyisobutylene (PIB), polyepichlorohydrin (PECH), polydimethylsiloxane (PDMS), polyisoprene(PIP) and polybutadiene(PBD). Their thin films were coated on quartz substrate by spin coating technique. Three types of simulants gases, dimethylmethylphosphonate(DMMP), acetonitrile (CH3CN) and dichloromethane(CH2Cl2), dichloropentane(DCP) were used as target gases, instead of the real nerve, blood, choking and vesicant agents. After spin coating of PIB and PECH, the substrates were heated to 65℃ with N2 flow for 1 h to remove the cyclohexane and ethylacetate which was used as solvent.PDMS was heated to 75℃ with N2 flow for 2 h to remove the ethylacetate which was used as solvent. PBD and PIP on the substrate were heated to 60℃ with N2 flow for 1 h to remove the benzen which was used as solvent. The sensing characteristics of the SAW sensors were measured by using E-5061A network analyzer.

  5. A molecularly imprinted polymer (MIP)-coated microbeam MEMS sensor for chemical detection

    Science.gov (United States)

    Holthoff, Ellen L.; Li, Lily; Hiller, Tobias; Turner, Kimberly L.

    2015-05-01

    Recently, microcantilever-based technology has emerged as a viable sensing platform due to its many advantages such as small size, high sensitivity, and low cost. However, microcantilevers lack the inherent ability to selectively identify hazardous chemicals (e.g., explosives, chemical warfare agents). The key to overcoming this challenge is to functionalize the top surface of the microcantilever with a receptor material (e.g., a polymer coating) so that selective binding between the cantilever and analyte of interest takes place. Molecularly imprinted polymers (MIPs) can be utilized as artificial recognition elements for target chemical analytes of interest. Molecular imprinting involves arranging polymerizable functional monomers around a template molecule followed by polymerization and template removal. The selectivity for the target analyte is based on the spatial orientation of the binding site and covalent or noncovalent interactions between the functional monomer and the analyte. In this work, thin films of sol-gel-derived xerogels molecularly imprinted for TNT and dimethyl methylphosphonate (DMMP), a chemical warfare agent stimulant, have demonstrated selectivity and stability in combination with a fixed-fixed beam microelectromechanical systems (MEMS)-based gas sensor. The sensor was characterized by parametric bifurcation noise-based tracking.

  6. Chemical gas sensors and the characterization, monitoring and sensor technology needs of the US Department of Energy

    Energy Technology Data Exchange (ETDEWEB)

    Bastiaans, G.J.; Haas, W.J. Jr.; Junk, G.A.

    1993-10-01

    The Office of Technology Development within the Dept. of Energy (DOE) has the responsibility of providing new technologies to aid the environmental restoration and waste management (ER/WM) activities of the DOE. There is a perception that application and judicious development of chemical sensor technologies could result in large cost savings and reduced risk to the health and safety of ER/WM personnel. A number of potential gas sensor applications which exist within DOE ER/WM operations are described. The capabilities of several chemical sensor technologies and their potential to meet the needs of ER/WM applications in the present or near term future are discussed.

  7. G3 Assisted Rational Design of Chemical Sensor Array Using Carbonitrile Neutral Receptors

    Directory of Open Access Journals (Sweden)

    Yatimah Alias

    2013-10-01

    Full Text Available Combined computational and experimental strategies for the systematic design of chemical sensor arrays using carbonitrile neutral receptors are presented. Binding energies of acetonitrile, n-pentylcarbonitrile and malononitrile with Ca(II, Mg(II, Be(II and H+ have been investigated with the B3LYP, G3, CBS-QB3, G4 and MQZVP methods, showing a general trend H+ > Be(II > Mg(II > Ca(II. Hydrogen bonding, donor-acceptor and cation-lone pair electron simple models were employed in evaluating the performance of computational methods. Mg(II is bound to acetonitrile in water by 12.5 kcal/mol, and in the gas phase the receptor is more strongly bound by 33.3 kcal/mol to Mg(II compared to Ca(II. Interaction of bound cations with carbonitrile reduces the energies of the MOs involved in the proposed σ-p conjugated network. The planar malononitrile-Be(II complex possibly involves a π-network with a cationic methylene carbon. Fabricated potentiometric chemical sensors show distinct signal patterns that can be exploited in sensor array applications.

  8. Dataset on photonic crystal fiber based chemical sensor.

    Science.gov (United States)

    Ahmed, Kawsar; Paul, Bikash Kumar; Chowdhury, Sawrab; Islam, Md Shadidul; Sen, Shuvo; Islam, Md Ibadul; Asaduzzaman, Sayed; Bahar, Ali Newaz; Miah, Mohammad Badrul Alam

    2017-06-01

    This article represents the data set of micro porous core photonic crystal fiber based chemical sensor. The suggested structure is folded cladding porous shaped with circular air hole. Here is investigated four distinctive parameters including relative sensitivity, confinement loss, numerical aperture (NA), and effective area (Aeff). The numerical outcomes are computed over the E+S+C+L+U communication band. The useable sensed chemicals are methanol, ethanol, propanol, butanol, and pentanol whose are lies in the alcohol series (Paul et al., 2017) [1]. Furthermore, V-parameter (V), Marcuse spot size (MSS), and beam divergence (BD) are also investigated rigorously. All examined results have been obtained using finite element method based simulation software COMSOL Multiphysics 4.2 versions with anisotropic circular perfectly matched layer (A-CPML). The proposed PCF shows the high NA from 0.35 to 0.36; the low CL from ~10(-11) to ~10(-7) dB/m; the high Aeff from 5.50 to 5.66 µm(2); the MSS from 1.0 to 1.08 µm; the BD from 0.43 to 0.46 rad at the controlling wavelength λ = 1.55 µm for employing alcohol series respectively.

  9. Dataset on photonic crystal fiber based chemical sensor

    Directory of Open Access Journals (Sweden)

    Kawsar Ahmed

    2017-06-01

    Full Text Available This article represents the data set of micro porous core photonic crystal fiber based chemical sensor. The suggested structure is folded cladding porous shaped with circular air hole. Here is investigated four distinctive parameters including relative sensitivity, confinement loss, numerical aperture (NA, and effective area (Aeff. The numerical outcomes are computed over the E+S+C+L+U communication band. The useable sensed chemicals are methanol, ethanol, propanol, butanol, and pentanol whose are lies in the alcohol series (Paul et al., 2017 [1]. Furthermore, V-parameter (V, Marcuse spot size (MSS, and beam divergence (BD are also investigated rigorously. All examined results have been obtained using finite element method based simulation software COMSOL Multiphysics 4.2 versions with anisotropic circular perfectly matched layer (A-CPML. The proposed PCF shows the high NA from 0.35 to 0.36; the low CL from ~10–11 to ~10−7 dB/m; the high Aeff from 5.50 to 5.66 µm2; the MSS from 1.0 to 1.08 µm; the BD from 0.43 to 0.46 rad at the controlling wavelength λ = 1.55 µm for employing alcohol series respectively.

  10. Semiconductor device-based sensors for gas, chemical, and biomedical applications

    CERN Document Server

    Ren, Fan

    2011-01-01

    Sales of U.S. chemical sensors represent the largest segment of the multi-billion-dollar global sensor market, which includes instruments for chemical detection in gases and liquids, biosensors, and medical sensors. Although silicon-based devices have dominated the field, they are limited by their general inability to operate in harsh environments faced with factors such as high temperature and pressure. Exploring how and why these instruments have become a major player, Semiconductor Device-Based Sensors for Gas, Chemical, and Biomedical Applications presents the latest research, including or

  11. Feasibility of a Stack Integrated SOFC Optical Chemical Sensor

    Energy Technology Data Exchange (ETDEWEB)

    Michael A. Carpenter

    2007-09-30

    The DOE-NETL Innovative Concepts (IC) phase II program investigated the feasibility of harsh environment compatible chemical sensors based on monitoring the surface plasmon resonance (SPR) bands of metal nanoparticle doped YSZ nano-cermets, as a function of fuel concentrations, impurities e.g. CO and temperature(500-900 C). In particular, Au nanoparticles (AuNPs) exhibit a strong surface plasmon resonance (SPR) band whose shape and spectral position is not only highly dependent on the refractive index of the host medium but also on chemical reactions at the interface between the metal and the surrounding environment. Studies have been completed on the oxygen and temperature dependence of the SPR band of the AuNPs, CO sensing studies, oxygen/hydrogen titration experiments, ethanol sensing studies and finally NO{sub 2} sensing studies. Reversible changes in the SPR band are observed for all chemical exposure studies with the sensing mechanism being determined by the oxidative or reductive properties of the exposure gases. Reactions which remove charge from the AuNPs was observed to cause a redshift in the SPR band, while charge donation to the AuNPs causes a blue shift in the SPR band. CO, hydrogen and ethanol in air mixtures were all reductive in nature as they reacted with the YSZ bound oxygen anions forming CO{sub 2} or H{sub 2}O thus ultimately inducing charge donation to the AuNPs and a blue shift in the SPR band. While NO{sub 2} and oxygen were oxidative and induced the production of YSZ bound oxygen anions, charge removal from the AuNPs and a redshift in the SPR band.

  12. Best Frequency for Temperature Modulation of Tin Oxide Gas Sensor for Chemical Vapor Identification

    OpenAIRE

    R Chutia; Bhuyan, M.

    2014-01-01

    In this paper, we describe a method of optimum temperature modulation of metal oxide semiconductor (MOS) based gas sensor, operated in dynamic temperature measurement for identification of gas. The volatile organic compound (VOC) sample space consists of fourteen laboratory chemicals sampled at various concentration. We have used eleven number of gas sensors, manufactured by Figaro sensors, Japan. The heater of the sensors were modulated with sawtooth heating waveform of different frequency. ...

  13. Selected area chemical vapor deposition of thin films for conductometric microelectronic chemical sensors

    Science.gov (United States)

    Majoo, Sanjeev

    Recent advances in microelectronics and silicon processing have been exploited to fabricate miniaturized chemical sensors. Although the capability of chemical sensing technology has grown steadily, it has been outpaced by the increasing demands for more reliable, inexpensive, and selective sensors. The diversity of applications requires the deployment of different sensing materials that have rich interfacial chemistry. However, several promising sensor materials are often incompatible with silicon micromachining and their deposition requires complicated masking steps. The new approach described here is to first micromachine a generic, instrumented, conductometric, microelectronic sensor platform that is fully functional except for the front-end sensing element. This generic platform contains a thin dielectric membrane, an integrated boron-doped silicon heater, and conductance electrodes. The membrane has low thermal mass and excellent thermal isolation. A proprietary selected-area chemical vapor deposition (SACVD) process in a cold-wall reactor at low pressures was then used to achieve maskless, self-lithographic deposition of thin films. The temperature-programmable integrated microheater initiates localized thermal decomposition/reaction of suitable CVD precursors confined to a small heated area (500 mum in diameter), and this creates the active sensing element. Platinum and titania (TiOsb2) films were deposited from pyrolysis of organometallic precursors, tetrakistrifluorophosphine platinum Pt(PFsb3)sb4 and titanium tetraisopropoxide Ti(OCH(CHsb3)sb2rbrack sb4, respectively. Deposition of gold metal films from chlorotriethylphosphine gold (Csb2Hsb5)sb3PAuCl precursor was also attempted but without success. The conductance electrodes permit in situ monitoring of film growth. The as-deposited films were characterized in situ by conductance measurements and optical microscopy and ex situ by electron microscopy and spectroscopy methods. Devices equipped with

  14. A chemically stable europium metal-organic framework for bifunctional chemical sensor and recyclable on-off-on vapor response

    Science.gov (United States)

    Wang, Dongbo; Liu, Jingjuan; Liu, Zhiliang

    2017-07-01

    A ratiometric luminescence sensing method is developed and makes the chemically stable Eu metal-organic framework to be the first bifunctional chemical sensor for Cd2+ and F- ions with naked-eye observation in the field of sensing applications utilizing luminescent Ln-MOFs. This is the first example of luminescent colorimetric sensor caused by the direct dual emissions of a single Ln-MOF. A recyclable vapoluminescent sensor for HCl and NH3 by the naked eye has also been realized.

  15. Wearable chemical sensing – sensor design and sampling techniques for real-time sweat analysis

    OpenAIRE

    2014-01-01

    Wearable chemical sensors have the potential to provide new methods of non-invasive physiological measurement. The nature of chemical sensors involves an active surface where a chemical reaction must occur to elicit a response. This adds complexity to a wearable system which creates challenges in the design of a reliable long-term working system. This work presents the design of a real-time sweat sensing platform to analyse sweat loss and composition. Sampling methods have an impact on...

  16. Tapered optical fiber sensor for chemical pollutants detection in seawater

    Science.gov (United States)

    Irigoyen, Maite; Sánchez-Martin, Jose Antonio; Bernabeu, Eusebio; Zamora, Alba

    2017-04-01

    Three tapered silica optical fibers, uncoated and coated with metallic (Al or Cu) and dielectric layers (TiO2), are employed to determine the presence of oil and Hazardous and Noxious Substances (HNS from now on) in water, by means of the measurement of their spectral transmittance. With our experimental assembly, the presence of oil and HNS spills can be detected employing the three different kinds of tapers, since the complete range of refractive indices of the pollutants (1.329-1.501) is covered with these tapers. The most suitable spectral range to detect the presence of a chemical pollutant in seawater has been identified and a complete spectral characterization of the three types of optical fiber tapers has been carried out. The results obtained show that, in general terms, these devices working together can be employed for the early detection of oil and HNS spills in seawater in a marine industrial environment. These sensors have many advantages, such as its low cost, its simplicity and versatility (with interesting properties as quick response and repeatability), and especially that they can be self-cleaned with seawater in motion.

  17. Field-effect transistor chemical sensors of single nanoribbon of copper phthalocyanine

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Copper phthalocyanine (CuPc) nanoribbon field-effect transistors were implemented as chemical sensors. They showed fast response and high reversibility in the detection of the tetrahydrofuran atmosphere at room temperature. The drain current of the field-effect transistor sensor decreased from 6.7 to 0.2 nA when the transistor was measured under the tetrahydrofuran atmosphere. The sensor was self-refreshable in a few minutes. These results demonstrate that the organic single crystalline nanoribbon transistors could effectively act as chemical sensors.

  18. Development of Low-cost Chemical and Micromechanical Sensors Based on Thick-film,Thin-film and Electroplated Films

    Institute of Scientific and Technical Information of China (English)

    Wenmin Qu; Kurt Drescher

    2000-01-01

    Various films could be used as sensing materials or as constructional materials for the fabrication of chemical and micromechanical sensors. To illustrate this potential, three sensors fabricated by very different film deposition technologies are given as examples. The sensors are a humidity sensor in thickfilm technology, a multi-functional gas sensor in thin-film technology and a three-dimensional acceleration sensor chip manufactured by electroplating techniques. Design, fabrication and characterisation of these sensors are described in this paper.

  19. Thin film chemical sensors based on chalcogenide glasses for ''electronic tongue'' application

    Energy Technology Data Exchange (ETDEWEB)

    Mourzina, Yu.; Legin, A.V.; Vlasov, Yu.G. [Sankt-Peterburgskij Univ., St. Petersburg (Russian Federation). Kafedra Khimii; Schoening, M.J. [Forschungszentrum Juelich GmbH (Germany). Abt. Sicherheit und Strahlenschutz]|[Univ. of Applied Sciences Aachen, Juelich (Germany); Schubert, J.; Zander, W.; Lueth, H. [Forschungszentrum Juelich GmbH (Germany). Abt. Sicherheit und Strahlenschutz

    2001-07-01

    A novel thin film preparation method, a pulsed laser deposition (PLD) technique, has been used in the present investigation to realise thin film chalcogenide layers for chemical sensor membranes. This technique is compatible with silicon technology and was aimed at fabrication of primary devices for analytical microsystems for the needs of fast analysis and in-situ measurements. The combination of the new type of the potentiometric thin film sensor array based on chalcogenide glass materials and artificial neural network for the experimental data processing is also presented. (orig.)

  20. Characterization and application of PBA fiber optic chemical film sensor based on fluorescence multiple quenching

    Institute of Scientific and Technical Information of China (English)

    陈坚; 李伟; 阎超; 袁立懋; 郭炬亮; 周新继

    1997-01-01

    The three types of structure of the pyrenebutyric acid of fiber optic chemical film sensor were stud-ied by fluorescence multiple quenching. They are, for different test samples and purposes, respectively general, three-way and combined. A tri-cup method was designed to demonstrate the multiple quenching of response mechanism, and a relationship formula of mathematical approach was established. The response mechanism was shown to include the dynamic quenching , inner-filter effects and/or resonance energy transfer. To show the response characterization in a series of organic and inorganic quenchers, a new concept of apparent quenching coefficient Kq was advanced. This kind of sensor has been used in continuous and in situ monitoring of the dissolution rate of drug tablets, on line and in situ monitoring of some organic therapeutic drugs in biological fluid and Cr( VI ) in industrial waste water. The measured data were examined and compared with HPLC or HPTLCS. Test results show that the sensors and appa

  1. Synthesis of Metal Oxide Nanomaterials for Chemical Sensors by Molecular Beam Epitaxy

    Energy Technology Data Exchange (ETDEWEB)

    Nandasiri, Manjula I.; Kuchibhatla, Satyanarayana V N T; Thevuthasan, Suntharampillai

    2013-12-01

    Since the industrial revolution, detection and monitoring of toxic matter, chemical wastes, and air pollutants has become an important environmental issue. Thus, it leads to the development of chemical sensors for various environmental applications. The recent disastrous oil spills over the near-surface of ocean due to the offshore drilling emphasize the use of chemical sensors for prevention and monitoring of the processes that might lead to these mishaps.1, 2 Chemical sensors operated on a simple principle that the sensing platform undergoes a detectable change when exposed to the target substance to be sensed. Among all the types of chemical sensors, solid state gas sensors have attracted a great deal of attention due to their advantages such as high sensitivity, greater selectivity, portability, high stability and low cost.3, 4 Especially, semiconducting metal oxides such as SnO2, TiO2, and WO3 have been widely used as the active sensing platforms in solid state gas sensors.5 For the enhanced properties of solid state gas sensors, finding new sensing materials or development of existing materials will be needed. Thus, nanostructured materials such as nanotubes,6-8 nanowires,9-11 nanorods,12-15 nanobelts,16, 17 and nano-scale thin films18-23 have been synthesized and studied for chemical sensing applications.

  2. A portable chemical sensor for histidine based on the strategy of click chemistry.

    Science.gov (United States)

    Zhou, Jin; Xu, Kefeng; Zhou, Ping; Zheng, Ou; Lin, Zhenyu; Guo, Longhua; Qiu, Bin; Chen, Guonan

    2014-01-15

    A novel portable chemical sensor is developed in combination of the personal glucose meters (PGM) with click chemistry for sensitive and selective determination of histidine. Invertase-labeled alkynyl-DNA can be modified onto the surfaces of Streptavidin Magnespheres Paramagnetic Particles (PMPs) through copper(I) catalyzed azide-alkyne cycloaddition (CuAAC) reaction and formed invertase-functionalized PMPs, which can be separated easily. The presence of invertase can convert sucrose to glucose and can be monitored by the PGM easily. The presence of histidine can inhibit the CuAAC, so the read-out signal of PGM decreased. The difference in signals from the PGM before and after addition of histidine has a good linear correlation with the logarithm of the histidine concentrations in the range of 0.01~100 μM with a detection limit of 3.4 nM, which is lower than those of many other chemical sensors. Moreover, the assay of histidine in milk samples is demonstrated with satisfactory results.

  3. Application and state of development for remote chemical sensors in environmental monitoring: A literature review

    Energy Technology Data Exchange (ETDEWEB)

    Schabron, J.F.; Niss, N.D.; Hart, B.K.

    1991-09-01

    A study was performed on chemical sensor technology currently available and under development. The information was compiled into a format wherein information on the sensors is listed in a comparable manner. An introductory section is provided to illustrate the regulatory environment in which such sensor technology will be used. This information should allow corporations or federal agencies ready access to useful information for the potential licensing of sensor technology for commercial development or specific environmental monitoring operations. Although every attempt was made to identify as many chemical sensors as possible, we recognize that some may be missed inadvertently. The accuracy of the information provided by the various sources regarding the state of development for the various sensors was not verified. Judgments or opinions regarding the actual state of development or utility of these devices are not included in this report. However, we feel that this report accurately reflects the state of the art at the present time.

  4. Application and state of development for remote chemical sensors in environmental monitoring: A literature review

    Energy Technology Data Exchange (ETDEWEB)

    Schabron, J.F.; Niss, N.D.; Hart, B.K.

    1991-09-01

    A study was performed on chemical sensor technology currently available and under development. The information was compiled into a format wherein information on the sensors is listed in a comparable manner. As introductory section is provided to illustrate the regulatory environment in which such sensor technology will be used. This information should allow corporations or federal agencies ready access to useful information for the potential licensing of sensor technology for commercial development or specific environmental monitoring operations. Although every attempt was made to identify as many chemical sensors as possible, we recognize that some may be missed inadvertently. The accuracy of the information provided by the various sources regarding the state of development for the various sensors was not verified. Judgments or opinions regarding the actual state of development or utility of these devices are not included in this report. However, we feel that this report accurately reflects the state of the art at the present time.

  5. Application and state of development for remote chemical sensors in environmental monitoring: A literature review

    Energy Technology Data Exchange (ETDEWEB)

    Schabron, J.F.; Niss, N.D.; Hart, B.K.

    1991-09-01

    A study was performed on chemical sensor technology currently available and under development. The information was compiled into a format wherein information on the sensors is listed in a comparable manner. An introductory section is provided to illustrate the regulatory environment in which such sensor technology will be used. This information should allow corporations or federal agencies ready access to useful information for the potential licensing of sensor technology for commercial development or specific environmental monitoring operations. Although every attempt was made to identify as many chemical sensors as possible, we recognize that some may be missed inadvertently. The accuracy of the information provided by the various sources regarding the state of development for the various sensors was not verified. Judgments or opinions regarding the actual state of development or utility of these devices are not included in this report. However, we feel that this report accurately reflects the state of the art at the present time.

  6. Application and state of development for remote chemical sensors in environmental monitoring: A literature review

    Energy Technology Data Exchange (ETDEWEB)

    Schabron, J.F.; Niss, N.D.; Hart, B.K.

    1991-09-01

    A study was performed on chemical sensor technology currently available and under development. The information was compiled into a format wherein information on the sensors is listed in a comparable manner. As introductory section is provided to illustrate the regulatory environment in which such sensor technology will be used. This information should allow corporations or federal agencies ready access to useful information for the potential licensing of sensor technology for commercial development or specific environmental monitoring operations. Although every attempt was made to identify as many chemical sensors as possible, we recognize that some may be missed inadvertently. The accuracy of the information provided by the various sources regarding the state of development for the various sensors was not verified. Judgments or opinions regarding the actual state of development or utility of these devices are not included in this report. However, we feel that this report accurately reflects the state of the art at the present time.

  7. ROC-curve approach for determining the detection limit of a field chemical sensor.

    Science.gov (United States)

    Fraga, Carlos G; Melville, Angela M; Wright, Bob W

    2007-03-01

    The detection limit of a field chemical sensor under realistic operating conditions is determined by receiver operator characteristic (ROC) curves. The chemical sensor is an ion mobility spectrometry (IMS) device used to detect a chemical marker in diesel fuel. The detection limit is the lowest concentration of the marker in diesel fuel that obtains the desired true-positive probability (TPP) and false-positive probability (FPP). A TPP of 0.90 and a FPP of 0.10 were selected as acceptable levels for the field sensor in this study. The detection limit under realistic operating conditions is found to be between 2 to 4 ppm (w/w). The upper value is the detection limit under challenging conditions. The ROC-based detection limit is very reliable because it is determined from multiple and repetitive sensor analyses under realistic circumstances. ROC curves also clearly illustrate and gauge the effects data preprocessing and sampling environments have on the sensor's detection limit.

  8. Nano-based chemical sensor array systems for uninhabited ground and airborne vehicles

    Science.gov (United States)

    Brantley, Christina; Ruffin, Paul B.; Edwards, Eugene

    2009-03-01

    In a time when homemade explosive devices are being used against soldiers and in the homeland security environment, it is becoming increasingly evident that there is an urgent need for high-tech chemical sensor packages to be mounted aboard ground and air vehicles to aid soldiers in determining the location of explosive devices and the origin of bio-chemical warfare agents associated with terrorist activities from a safe distance. Current technologies utilize relatively large handheld detection systems that are housed on sizeable robotic vehicles. Research and development efforts are underway at the Army Aviation & Missile Research, Development, and Engineering Center (AMRDEC) to develop novel and less expensive nano-based chemical sensors for detecting explosives and chemical agents used against the soldier. More specifically, an array of chemical sensors integrated with an electronics control module on a flexible substrate that can conform to and be surface-mounted to manned or unmanned vehicles to detect harmful species from bio-chemical warfare and other explosive devices is being developed. The sensor system under development is a voltammetry-based sensor system capable of aiding in the detection of any chemical agent and in the optimization of sensor microarray geometry to provide nonlinear Fourier algorithms to characterize target area background (e.g., footprint areas). The status of the research project is reviewed in this paper. Critical technical challenges associated with achieving system cost, size, and performance requirements are discussed. The results obtained from field tests using an unmanned remote controlled vehicle that houses a CO2/chemical sensor, which detects harmful chemical agents and wirelessly transmits warning signals back to the warfighter, are presented. Finally, the technical barriers associated with employing the sensor array system aboard small air vehicles will be discussed.

  9. Application of Photocured Polymer Ion Selective Membranes for Solid-State Chemical Sensors

    Directory of Open Access Journals (Sweden)

    Natalia Abramova

    2015-06-01

    Full Text Available Application of conducting polymers with additional functional groups for a solid contact formation and photocurable membranes as sensitive elements of solid-state chemical sensors is discussed. Problems associated with application of UV-curable polymers for sensors are analyzed. A method of sensor fabrication using copolymerized conductive layer and sensitive membrane is presented and the proof of concept is confirmed by two examples of solid-contact electrodes for Ca ions and pH.

  10. Carbon Nanostructure-Based Field-Effect Transistors for Label-Free Chemical/Biological Sensors

    Directory of Open Access Journals (Sweden)

    PingAn Hu

    2010-05-01

    Full Text Available Over the past decade, electrical detection of chemical and biological species using novel nanostructure-based devices has attracted significant attention for chemical, genomics, biomedical diagnostics, and drug discovery applications. The use of nanostructured devices in chemical/biological sensors in place of conventional sensing technologies has advantages of high sensitivity, low decreased energy consumption and potentially highly miniaturized integration. Owing to their particular structure, excellent electrical properties and high chemical stability, carbon nanotube and graphene based electrical devices have been widely developed for high performance label-free chemical/biological sensors. Here, we review the latest developments of carbon nanostructure-based transistor sensors in ultrasensitive detection of chemical/biological entities, such as poisonous gases, nucleic acids, proteins and cells.

  11. X-Ray Photoelectron Spectroscopic Characterization of Chemically Modified Electrodes Used as Chemical Sensors and Biosensors: A Review

    Directory of Open Access Journals (Sweden)

    Elio Desimoni

    2015-04-01

    Full Text Available The characterization of chemically modified sensors and biosensors is commonly performed by cyclic voltammetry and electron microscopies, which allow verifying electrode mechanisms and surface morphologies. Among other techniques, X-ray photoelectron spectroscopy (XPS plays a unique role in giving access to qualitative, quantitative/semi-quantitative and speciation information concerning the sensor surface. Nevertheless, XPS remains rather underused in this field. The aim of this paper is to review selected articles which evidence the useful performances of XPS in characterizing the top surface layers of chemically modified sensors and biosensors. A concise introduction to X-ray Photoelectron Spectroscopy gives to the reader the essential background. The application of XPS for characterizing sensors suitable for food and environmental analysis is highlighted.

  12. Single walled carbon nanotubes with functionally adsorbed biopolymers for use as chemical sensors

    Science.gov (United States)

    Johnson, Jr., Alan T

    2013-12-17

    Chemical field effect sensors comprising nanotube field effect devices having biopolymers such as single stranded DNA or RNA functionally adsorbed to the nanotubes are provided. Also included are arrays comprising the sensors and methods of using the devices to detect volatile compounds.

  13. Piezoelectric microelectromechanical resonant sensors for chemical and biological detection.

    Science.gov (United States)

    Pang, Wei; Zhao, Hongyuan; Kim, Eun Sok; Zhang, Hao; Yu, Hongyu; Hu, Xiaotang

    2012-01-07

    Piezoelectric microelectromechanical systems (MEMS) resonant sensors, known for their excellent mass resolution, have been studied for many applications, including DNA hybridization, protein-ligand interactions, and immunosensor development. They have also been explored for detecting antigens, organic gas, toxic ions, and explosives. Most piezoelectric MEMS resonant sensors are acoustic sensors (with specific coating layers) that enable selective and label-free detection of biological events in real time. These label-free technologies have recently garnered significant attention for their sensitive and quantitative multi-parameter analysis of biological systems. Since piezoelectric MEMS resonant sensors do more than transform analyte mass or thickness into an electrical signal (e.g., frequency and impedance), special attention must be paid to their potential beyond microweighing, such as measuring elastic and viscous properties, and several types of sensors currently under development operate at different resonant modes (i.e., thickness extensional mode, thickness shear mode, lateral extensional mode, flexural mode, etc.). In this review, we provide an overview of recent developments in micromachined resonant sensors and activities relating to biochemical interfaces for acoustic sensors.

  14. Chemical gas sensor application of open-pore mesoporous thin films based on integrated optical polarimetric interferometry.

    Science.gov (United States)

    Qi, Zhi-Mei; Honma, Itaru; Zhou, Haoshen

    2006-02-15

    Chemical gas sensors that employ integrated optical polarimetric interferometry were fabricated by the sol-gel synthesis of transparent mesoporous thin films of TiO2-P2O5 nanocomposite on tapered layers of TiO2 sputtered on tin-diffused glass waveguides. Atomic force microscopy images of the mesoporous thin film clearly show the open pore mouths on the film surface that favor rapid diffusion and adsorption of gas-phase analytes within the entire film. Adsorption of gas and vapor induces changes (Deltan) in the refractive index of the mesoporous thin film that lead to shifts in the phase difference between the fundamental transverse electric and magnetic modes simultaneously excited in the glass waveguide via single-beam incidence. Upon exposure to NH3 gas at concentrations as low as 100 ppb in dry air at room temperature, the sensor exhibits a reversible change in the phase difference with the response and recovery times of less than 60 and 90 s, respectively. It is unexpected that the sensor is unresponsive to either NO2 or C6H6 vapor, leading to a somewhat selective sensitivity to NH3. Determination of Deltan was carried out with a combination of the experimental results and the theoretical calculations. The sensor design represents a novel, effective, and easily accessible approach to mesoporous thin-film-based integrated optical chemical sensors.

  15. Wide Dynamic Range CMOS Potentiostat for Amperometric Chemical Sensor

    OpenAIRE

    Wei-Song Wang; Wei-Ting Kuo; Hong-Yi Huang; Ching-Hsing Luo

    2010-01-01

    Presented is a single-ended potentiostat topology with a new interface connection between sensor electrodes and potentiostat circuit to avoid deviation of cell voltage and linearly convert the cell current into voltage signal. Additionally, due to the increased harmonic distortion quantity when detecting low-level sensor current, the performance of potentiostat linearity which causes the detectable current and dynamic range to be limited is relatively decreased. Thus, to alleviate these irreg...

  16. Morphology tailoring of nano/micro-structured conductive polymers, composites and their applications in chemical sensors.

    Science.gov (United States)

    Ma, Xingfa; Gao, Mingjun; He, Xiaochun; Li, Guang

    2010-11-01

    Conductive polymer is one of the important multi-functional materials. It has many applications in light-emitting diodes, chemical sensors, biosensors, et al. This paper provides a relatively comprehensive review on the progress of conductive polymer and composite as sensitive film for sensors to chemical vapors including patents, papers and our preliminary research results. Especially, the feature of conjugated polymers, the processing technology, doping characteristics and some factors affecting gas responses are discussed. Otherwise, the developments of nanostructured conductive polymer and organic-inorganic hybrid film sensor with high sensitivity and rapid response to vapors are also described, and some suggestions are proposed.

  17. Micro- and Nanostructured Metal Oxide Chemical Sensors for Volatile Organic Compounds

    Science.gov (United States)

    Alim, M. A.; Penn, B. G.; Currie, J. R., Jr.; Batra, A. K.; Aggarwal, M. D.

    2008-01-01

    Aeronautic and space applications warrant the development of chemical sensors which operate in a variety of environments. This technical memorandum incorporates various kinds of chemical sensors and ways to improve their performance. The results of exploratory investigation of the binary composite polycrystalline thick-films such as SnO2-WO3, SnO2-In2O3, SnO2-ZnO for the detection of volatile organic compound (isopropanol) are reported. A short review of the present status of the new types of nanostructured sensors such as nanobelts, nanorods, nanotube, etc. based on metal oxides is presented.

  18. On the sensitivity, selectivity, sensory information and optimal size of resistive chemical sensors

    CERN Document Server

    Kish, L B; Heszler, P; Smulko, J; Granqvist, Claes-Goran; Heszler, Peter; Kish, Laszlo B.; Smulko, Janusz

    2007-01-01

    Information theoretical tools are applied for the study of the sensitivity and selectivity enhancements of resistive fluctuation-enhanced sensors. General considerations are given for the upper limit of selectivity enhancement. The signal-to-noise ratio and information channel capacity of fluctuation-enhanced chemical sensors is compared to that of classical sensors providing a single output. The considerations are done at the generic level with a few concrete examples and include the estimation of scaling relations between the sensor size, the signal power, the noise power and the speed of measurements versus the size, sampling rate and measurement time.

  19. Designing multifunctional chemical sensors using Ni and Cu doped carbon nanotubes

    DEFF Research Database (Denmark)

    Mowbray, Duncan; García Lastra, Juan Maria; Thygesen, Kristian Sommer

    2010-01-01

    We demonstrate a “bottom up” approach to the computational design of a multifunctional chemical sensor. General techniques are employed for describing the adsorption coverage and resistance properties of the sensor based on density functional theory and non-equilibrium Green's function methodolog......We demonstrate a “bottom up” approach to the computational design of a multifunctional chemical sensor. General techniques are employed for describing the adsorption coverage and resistance properties of the sensor based on density functional theory and non-equilibrium Green's function...... methodologies, respectively. Specifically, we show how Ni and Cu doped metallic (6,6) single-walled carbon nanotubes may work as effective multifunctional sensors for both CO and NH3....

  20. Chemical Sensing Using Infrared Cavity Enhanced Spectroscopy: Short Wave Infrared Cavity Ring Down Spectroscopy (SWIR CRDS) Sensor

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Richard M.; Harper, Warren W.; Aker, Pam M.; Thompson, Jason S.; Stewart, Timothy L.

    2003-10-01

    ) quantum cascade lasers as the light source. This report details the research and discoveries made on the SWIR CRDS project. While chemical detection limits in the SWIR is not expected to be as low as that in the LWIR, there are a number of reasons for designing sensors that operate in this region. First and foremost is that high quality SWIR lasers, detectors and optics are commercially available. Technological advances made in the telecommunications sector have yielded photonic components that are robust, low power, compact and operate at room temperature. These components can be quickly combined and assembled to produce a sensor prototype. This is exactly what we have done with our cavity ring down sensor. We assembled our first prototype instrument in FY02, tested it in the laboratory, developed the chemometrics, and defined several improvements that needed to be implemented before trialing this sensor in the field. In FY03 we completed the refinements, retested the sensor in the laboratory, and then conducted our first field campaign. Our success was demonstrated by the ability of our SWIR CRDS to run autonomously and continuously for 7 days when located in PNNL's Shipping and Receiving Building. No false positive alarms were detected even though the environment was contaminated with vehicle exhaust fumes, dirt, dust, and volatile organic chemicals associated with packaging materials. The instrument maintained its detection threshold and calibration throughout the test. Small fluctuations that we observed in the background concentration levels have led us to develop a more robust method for calibrating the instrument, and separate tests we conducted in the laboratory have afforded a means to account interference from species that have very broad, but weak absorption in this spectral region. We outline all of these accomplishments in detail in the body of this report.

  1. Chemical Kinetics, Heat Transfer, and Sensor Dynamics Revisited in a Simple Experiment

    Science.gov (United States)

    Sad, Maria E.; Sad, Mario R.; Castro, Alberto A.; Garetto, Teresita F.

    2008-01-01

    A simple experiment about thermal effects in chemical reactors is described, which can be used to illustrate chemical reactor models, the determination and validation of their parameters, and some simple principles of heat transfer and sensor dynamics. It is based in the exothermic reaction between aqueous solutions of sodium thiosulfate and…

  2. Integrated label-free silicon nanowire sensor arrays for (bio)chemical analysis

    NARCIS (Netherlands)

    De, Arpita; Nieuwkasteele, van Jan; Carlen, Edwin T.; Berg, van den Albert

    2013-01-01

    We present a label-free (bio)chemical analysis platform that uses all-electrical silicon nanowire sensor arrays integrated with a small volume microfluidic flow-cell for real-time (bio)chemical analysis and detection. The integrated sensing platform contains an automated multi-sample injection syste

  3. Chemical Kinetics, Heat Transfer, and Sensor Dynamics Revisited in a Simple Experiment

    Science.gov (United States)

    Sad, Maria E.; Sad, Mario R.; Castro, Alberto A.; Garetto, Teresita F.

    2008-01-01

    A simple experiment about thermal effects in chemical reactors is described, which can be used to illustrate chemical reactor models, the determination and validation of their parameters, and some simple principles of heat transfer and sensor dynamics. It is based in the exothermic reaction between aqueous solutions of sodium thiosulfate and…

  4. Sensory quality control of alcoholic beverages using fast chemical sensors

    OpenAIRE

    2010-01-01

    Control de calidad sensorial de bebidas alcohólicas utilizando rápidos sensores químicosEn la presente tesis Doctoral, han sido aplicados dos sensores artificiales para el análisis debebidas alcohólicas: la nariz electrónica basada en la espectrometría de masas (MS) y la lenguaelectrónica basada en la espectroscopía infrarroja con transformada de Fourier (FTIR). Elpropósito fue desarrollar nuevas estrategias para analizar la autenticidad de estos productos,desde un punto de vista sensorial, p...

  5. Fusing Sensor Paradigms to Acquire Chemical Information: An Integrative Role for Smart Biopolymeric Hydrogels.

    Science.gov (United States)

    Kim, Eunkyoung; Liu, Yi; Ben-Yoav, Hadar; Winkler, Thomas E; Yan, Kun; Shi, Xiaowen; Shen, Jana; Kelly, Deanna L; Ghodssi, Reza; Bentley, William E; Payne, Gregory F

    2016-10-01

    The Information Age transformed our lives but it has had surprisingly little impact on the way chemical information (e.g., from our biological world) is acquired, analyzed and communicated. Sensor systems are poised to change this situation by providing rapid access to chemical information. This access will be enabled by technological advances from various fields: biology enables the synthesis, design and discovery of molecular recognition elements as well as the generation of cell-based signal processors; physics and chemistry are providing nano-components that facilitate the transmission and transduction of signals rich with chemical information; microfabrication is yielding sensors capable of receiving these signals through various modalities; and signal processing analysis enhances the extraction of chemical information. The authors contend that integral to the development of functional sensor systems will be materials that (i) enable the integrative and hierarchical assembly of various sensing components (for chemical recognition and signal transduction) and (ii) facilitate meaningful communication across modalities. It is suggested that stimuli-responsive self-assembling biopolymers can perform such integrative functions, and redox provides modality-spanning communication capabilities. Recent progress toward the development of electrochemical sensors to manage schizophrenia is used to illustrate the opportunities and challenges for enlisting sensors for chemical information processing.

  6. Flexible intramuscular micro tube electrode combining electrical and chemical interface.

    Science.gov (United States)

    Tian, Hong-Chang; Liu, Jing-Quan; Du, Jing-Cheng; Kang, Xiao-Yang; Zhang, Chuan; Yang, Bin; Chen, Xiang; Yang, Chun-Sheng

    2014-01-01

    With the rapidly developed micromachining technology, various kinds of sophisticated microelectrodes integrated with micro fluidic channels are design and fabricated for not only electrophysiological recording and stimulation, but also chemical drug delivery. As many efforts have been devoted to develop rigid microprobes for neural research of brain, few researchers concentrate on fabrication of flexible microelectrodes for intramuscular electrophysiology and chemical interfacing. Since crude wire electrodes still prevail in functional electrical stimulation (FES) and electromyography (EMG) recording of muscle, here we introduce a flexible micro tube electrode combining electrical and chemical pathway. The proposed micro tube electrode is manufactured based on polymer capillary, which provide circumferential electrode site contacting with electro-active tissue and is easy to manufactured with low cost.

  7. Improved fiber-optic chemical sensor for penicillin

    Energy Technology Data Exchange (ETDEWEB)

    Healy, B.G.; Walt, D.R. [Tufts Univ., Medford, MA (United States)

    1995-12-15

    An optical penicillin biosensor is described, based on the enzyme penicillinase. The sensor is fabricated by selective photodeposition of analyte-sensitive polymer matrices on optical imaging fibers. The penicillin-sensitive matrices are fabricated by immobilizing the enzyme as micrometer-sized particles in a polymer hydrogel with a covalently bound pH indicator. An array of penicillin-sensitive and pH-sensitive matrices are fabricated on the same fiber. This array allows for the simultaneous, independent measurement of pH and penicillin. Independent measurement of the two analytes allows penicillin to be quantitated in the presence of a concurrent pH change. An analysis was conducted of enzyme kinetic parameters in order to model the penicillin response of the sensor at all pH values. This analysis accounts for the varying activity of the immobilized penicillinase at different pH values. The sensor detects penicillin in the range 0.25-10.0 mM in the pH range 6.2-7.5. The sensor was used to quantify penicillin concentration produced during a Penicillium chrysogenum fermentation. 27 refs., 7 figs., 1 tab.

  8. Development of new sensors for detection of organic chemicals

    DEFF Research Database (Denmark)

    Bache, Michael

    koncentrationer af kemikalier. En cantilever baseret overflade stress sensor er undersøgt som en mulig metode til påvisning af 2,6-dichlorbenzamid (BAM) pesticidrester i vand. Cantilever overflade stress princip blev undersøgt ved hjælp af piezo resistiv system fra Cantion/Nanonord A/S, og en optisk laser...

  9. Dynamic 3-D chemical agent cloud mapping using a sensor constellation deployed on mobile platforms

    Science.gov (United States)

    Cosofret, Bogdan R.; Konno, Daisei; Rossi, David; Marinelli, William J.; Seem, Pete

    2014-05-01

    The need for standoff detection technology to provide early Chem-Bio (CB) threat warning is well documented. Much of the information obtained by a single passive sensor is limited to bearing and angular extent of the threat cloud. In order to obtain absolute geo-location, range to threat, 3-D extent and detailed composition of the chemical threat, fusion of information from multiple passive sensors is needed. A capability that provides on-the-move chemical cloud characterization is key to the development of real-time Battlespace Awareness. We have developed, implemented and tested algorithms and hardware to perform the fusion of information obtained from two mobile LWIR passive hyperspectral sensors. The implementation of the capability is driven by current Nuclear, Biological and Chemical Reconnaissance Vehicle operational tactics and represents a mission focused alternative of the already demonstrated 5-sensor static Range Test Validation System (RTVS).1 The new capability consists of hardware for sensor pointing and attitude information which is made available for streaming and aggregation as part of the data fusion process for threat characterization. Cloud information is generated using 2-sensor data ingested into a suite of triangulation and tomographic reconstruction algorithms. The approaches are amenable to using a limited number of viewing projections and unfavorable sensor geometries resulting from mobile operation. In this paper we describe the system architecture and present an analysis of results obtained during the initial testing of the system at Dugway Proving Ground during BioWeek 2013.

  10. Highly sensitive fiber grating chemical sensors: An effective alternative to atomic absorption spectroscopy

    Science.gov (United States)

    Laxmeshwar, Lata. S.; Jadhav, Mangesh S.; Akki, Jyoti. F.; Raikar, Prasad; Kumar, Jitendra; prakash, Om; Raikar, U. S.

    2017-06-01

    Accuracy in quantitative determination of trace elements like Zinc, present in drinking water in ppm level, is a big challenge and optical fiber gratings as chemical sensors may provide a promising solution to overcome the same. This paper presents design of two simple chemical sensors based on the principle of shift in characteristic wavelength of gratings with change in their effective refractive index, to measure the concentration of Zinc in drinking water using etched short period grating (FBG) and Long period grating (LPG) respectively. Three samples of drinking water from different places have been examined for presence of Zinc. Further, the results obtained by our sensors have also been verified with the results obtained by a standard method, Atomic absorption spectroscopy (AAS). The whole experiment has been performed by fixing the fibers in a horizontal position with the sensor regions at the center of the fibers, making it less prone to disturbance and breaking. The sensitivity of LPG sensor is about 205 times that of the FBG sensor. A few advantages of Fiber grating sensors, besides their regular features, over AAS have also been discussed, that make our sensors potential alternatives for existing techniques in determination of trace elements in drinking water.

  11. Development of Fabric-Based Chemical Gas Sensors for Use as Wearable Electronic Noses

    Directory of Open Access Journals (Sweden)

    Thara Seesaard

    2015-01-01

    Full Text Available Novel gas sensors embroidered into fabric substrates based on polymers/ SWNT-COOH nanocomposites were proposed in this paper, aiming for their use as a wearable electronic nose (e-nose. The fabric-based chemical gas sensors were fabricated by two main processes: drop coating and embroidery. Four potential polymers (PVC, cumene-PSMA, PSE and PVP/functionalized-SWCNT sensing materials were deposited onto interdigitated electrodes previously prepared by embroidering conductive thread on a fabric substrate to make an optimal set of sensors. After preliminary trials of the obtained sensors, it was found that the sensors yielded a electrical resistance in the region of a few kilo-Ohms. The sensors were tested with various volatile compounds such as ammonium hydroxide, ethanol, pyridine, triethylamine, methanol and acetone, which are commonly found in the wastes released from the human body. These sensors were used to detect and discriminate between the body odors of different regions and exist in various forms such as the urine, armpit and exhaled breath odor. Based on a simple pattern recognition technique, we have shown that the proposed fabric-based chemical gas sensors can discriminate the human body odor from two persons.

  12. The Combination of Micro Diaphragm Pumps and Flow Sensors for Single Stroke Based Liquid Flow Control.

    Science.gov (United States)

    Jenke, Christoph; Pallejà Rubio, Jaume; Kibler, Sebastian; Häfner, Johannes; Richter, Martin; Kutter, Christoph

    2017-04-03

    With the combination of micropumps and flow sensors, highly accurate and secure closed-loop controlled micro dosing systems for liquids are possible. Implementing a single stroke based control mode with piezoelectrically driven micro diaphragm pumps can provide a solution for dosing of volumes down to nanoliters or variable average flow rates in the range of nL/min to μL/min. However, sensor technologies feature a yet undetermined accuracy for measuring highly pulsatile micropump flow. Two miniaturizable in-line sensor types providing electrical readout-differential pressure based flow sensors and thermal calorimetric flow sensors-are evaluated for their suitability of combining them with mircopumps. Single stroke based calibration of the sensors was carried out with a new method, comparing displacement volumes and sensor flow volumes. Limitations of accuracy and performance for single stroke based flow control are described. Results showed that besides particle robustness of sensors, controlling resistive and capacitive damping are key aspects for setting up reproducible and reliable liquid dosing systems. Depending on the required average flow or defined volume, dosing systems with an accuracy of better than 5% for the differential pressure based sensor and better than 6.5% for the thermal calorimeter were achieved.

  13. Combined physical and chemical nonequilibrium transport model for solution conduits.

    Science.gov (United States)

    Field, Malcolm S; Leij, Feike J

    2014-02-01

    Solute transport in karst aquifers is primarily constrained to relatively complex and inaccessible solution conduits where transport is often rapid, turbulent, and at times constrictive. Breakthrough curves generated from tracer tests in solution conduits are typically positively-skewed with long tails evident. Physical nonequilibrium models to fit breakthrough curves for tracer tests in solution conduits are now routinely employed. Chemical nonequilibrium processes are likely important interactions, however. In addition to partitioning between different flow domains, there may also be equilibrium and nonequilibrium partitioning between the aqueous and solid phases. A combined physical and chemical nonequilibrium (PCNE) model was developed for an instantaneous release similar to that developed by Leij and Bradford (2009) for a pulse release. The PCNE model allows for partitioning open space in solution conduits into mobile and immobile flow regions with first-order mass transfer between the two regions to represent physical nonequilibrium in the conduit. Partitioning between the aqueous and solid phases proceeds either as an equilibrium process or as a first-order process and represents chemical nonequilibrium for both the mobile and immobile regions. Application of the model to three example breakthrough curves demonstrates the applicability of the combined physical and chemical nonequilibrium model to tracer tests conducted in karst aquifers, with exceptionally good model fits to the data. The three models, each from a different state in the United States, exhibit very different velocities, dispersions, and other transport properties with most of the transport occurring via the fraction of mobile water. Fitting the model suggests the potentially important interaction of physical and chemical nonequilibrium processes.

  14. Time-resolved fluorescence spectroscopy for chemical sensors

    Science.gov (United States)

    Draxler, Sonja; Lippitsch, Max E.

    1996-07-01

    A family of sensors is presented with fluorescence decay-time measurements used as the sensing technique. The concept is to take a single fluorophore with a suitably long fluorescence decay time as the basic building block for numerous different sensors. Analyte recognition can be performed by different functional groups that are necessary for selective interaction with the analyte. To achieve this, the principle of excited-state electron transfer is applied with pyrene as the fluorophore. Therefore the same instrumentation based on a small, ambient air-nitrogen laser and solid-state electronics can be used to measure different analytes, for example, oxygen, pH, carbon dioxide, potassium, ammonium, lead, cadmium, zinc, and phosphate.

  15. SPE Membrane Electrode and Its Application to Chemical Sensor

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The structure and proton conducting mechanism of solid polymer electrolyte (SPE) are described. Since the conductivity of electrolyte is important in SPE electrochemical cell research and development, we investigate quantitatively the conductivity of Nafion membrane and its dependence on temperature and relative humidity. Ex perimental results show that the conductivity of Nafion membrane increases with temperature and relative humidity. We also reports on the preparation and development of SPE membrane electrode with the emphasis on the mix ture pressing method and impregnation-reduction process to prepare SPE composite electrode assemblies and their application to electrochemical sensors. We also investigate and fabricate a potentiometric electrochemical sensor of hydrogen and ethylene to measure the hydrogen and ethylene partial pressure.

  16. Wide Dynamic Range CMOS Potentiostat for Amperometric Chemical Sensor

    Directory of Open Access Journals (Sweden)

    Wei-Song Wang

    2010-03-01

    Full Text Available Presented is a single-ended potentiostat topology with a new interface connection between sensor electrodes and potentiostat circuit to avoid deviation of cell voltage and linearly convert the cell current into voltage signal. Additionally, due to the increased harmonic distortion quantity when detecting low-level sensor current, the performance of potentiostat linearity which causes the detectable current and dynamic range to be limited is relatively decreased. Thus, to alleviate these irregularities, a fully-differential potentiostat is designed with a wide output voltage swing compared to single-ended potentiostat. Two proposed potentiostats were implemented using TSMC 0.18-μm CMOS process for biomedical application. Measurement results show that the fully differential potentiostat performs relatively better in terms of linearity when measuring current from 500 ºpA to 10 uA. Besides, the dynamic range value can reach a value of 86 dB.

  17. Chemical Sensors Based on Molecularly Imprinted Sol-Gel Materials

    OpenAIRE

    Dickert, Franz L.; Lieberzeit, Peter A.; Adnan Mujahid

    2010-01-01

    The sol-gel technique is earning the worldwide attention of researchers in the field of material science, due to its versatility in synthesizing inorganic ceramic materials at mild conditions. High purity, homogeneity, controlled porosity, stable temperature and nanoscale structuring are the most remarkable features offered by this method for generating highly sensitive and selective matrices to incorporate analyte molecules. The crafting of sol-gel sensors through molecular imprinting has pu...

  18. Recent Development in Optical Chemical Sensors Coupling with Flow Injection Analysis

    Directory of Open Access Journals (Sweden)

    Fuensanta Sánchez Rojas

    2006-10-01

    Full Text Available Optical techniques for chemical analysis are well established and sensors based on thesetechniques are now attracting considerable attention because of their importance in applications suchas environmental monitoring, biomedical sensing, and industrial process control. On the other hand,flow injection analysis (FIA is advisable for the rapid analysis of microliter volume samples and canbe interfaced directly to the chemical process. The FIA has become a widespread automatic analyticalmethod for more reasons; mainly due to the simplicity and low cost of the setups, their versatility, andease of assembling. In this paper, an overview of flow injection determinations by using opticalchemical sensors is provided, and instrumentation, sensor design, and applications are discussed. Thiswork summarizes the most relevant manuscripts from 1980 to date referred to analysis using opticalchemical sensors in FIA.

  19. A Novel Wearable Electronic Nose for Healthcare Based on Flexible Printed Chemical Sensor Array

    Directory of Open Access Journals (Sweden)

    Panida Lorwongtragool

    2014-10-01

    Full Text Available A novel wearable electronic nose for armpit odor analysis is proposed by using a low-cost chemical sensor array integrated in a ZigBee wireless communication system. We report the development of a carbon nanotubes (CNTs/polymer sensor array based on inkjet printing technology. With this technique both composite-like layer and actual composite film of CNTs/polymer were prepared as sensing layers for the chemical sensor array. The sensor array can response to a variety of complex odors and is installed in a prototype of wearable e-nose for monitoring the axillary odor released from human body. The wearable e-nose allows the classification of different armpit odors and the amount of the volatiles released as a function of level of skin hygiene upon different activities.

  20. A Novel Wearable Electronic Nose for Healthcare Based on Flexible Printed Chemical Sensor Array

    Science.gov (United States)

    Lorwongtragool, Panida; Sowade, Enrico; Watthanawisuth, Natthapol; Baumann, Reinhard R.; Kerdcharoen, Teerakiat

    2014-01-01

    A novel wearable electronic nose for armpit odor analysis is proposed by using a low-cost chemical sensor array integrated in a ZigBee wireless communication system. We report the development of a carbon nanotubes (CNTs)/polymer sensor array based on inkjet printing technology. With this technique both composite-like layer and actual composite film of CNTs/polymer were prepared as sensing layers for the chemical sensor array. The sensor array can response to a variety of complex odors and is installed in a prototype of wearable e-nose for monitoring the axillary odor released from human body. The wearable e-nose allows the classification of different armpit odors and the amount of the volatiles released as a function of level of skin hygiene upon different activities. PMID:25340447

  1. Safety evaluation of chemical mixtures and combinations of chemical and non-chemical stressors

    NARCIS (Netherlands)

    Jonker, D.; Freidig, A.P.; Groten, J.P.; Hollander, A.E.M.de; Stierum, R.H.; Woutersen, R.A.; Feron, V.J.

    2004-01-01

    Recent developments in hazard identification and risk assessment of chemical mixtures are reviewed. Empirical, descriptive approaches to study and characterize the toxicity of mixtures have dominated during the past two decades, but an increasing number of mechanistic approaches have made their entr

  2. Slaughterhouse wastewater treatment by combined chemical coagulation and electrocoagulation process.

    Science.gov (United States)

    Bazrafshan, Edris; Kord Mostafapour, Ferdos; Farzadkia, Mehdi; Ownagh, Kamal Aldin; Mahvi, Amir Hossein

    2012-01-01

    Slaughterhouse wastewater contains various and high amounts of organic matter (e.g., proteins, blood, fat and lard). In order to produce an effluent suitable for stream discharge, chemical coagulation and electrocoagulation techniques have been particularly explored at the laboratory pilot scale for organic compounds removal from slaughterhouse effluent. The purpose of this work was to investigate the feasibility of treating cattle-slaughterhouse wastewater by combined chemical coagulation and electrocoagulation process to achieve the required standards. The influence of the operating variables such as coagulant dose, electrical potential and reaction time on the removal efficiencies of major pollutants was determined. The rate of removal of pollutants linearly increased with increasing doses of PACl and applied voltage. COD and BOD(5) removal of more than 99% was obtained by adding 100 mg/L PACl and applied voltage 40 V. The experiments demonstrated the effectiveness of chemical and electrochemical techniques for the treatment of slaughterhouse wastewaters. Consequently, combined processes are inferred to be superior to electrocoagulation alone for the removal of both organic and inorganic compounds from cattle-slaughterhouse wastewater.

  3. Slaughterhouse wastewater treatment by combined chemical coagulation and electrocoagulation process.

    Directory of Open Access Journals (Sweden)

    Edris Bazrafshan

    Full Text Available Slaughterhouse wastewater contains various and high amounts of organic matter (e.g., proteins, blood, fat and lard. In order to produce an effluent suitable for stream discharge, chemical coagulation and electrocoagulation techniques have been particularly explored at the laboratory pilot scale for organic compounds removal from slaughterhouse effluent. The purpose of this work was to investigate the feasibility of treating cattle-slaughterhouse wastewater by combined chemical coagulation and electrocoagulation process to achieve the required standards. The influence of the operating variables such as coagulant dose, electrical potential and reaction time on the removal efficiencies of major pollutants was determined. The rate of removal of pollutants linearly increased with increasing doses of PACl and applied voltage. COD and BOD(5 removal of more than 99% was obtained by adding 100 mg/L PACl and applied voltage 40 V. The experiments demonstrated the effectiveness of chemical and electrochemical techniques for the treatment of slaughterhouse wastewaters. Consequently, combined processes are inferred to be superior to electrocoagulation alone for the removal of both organic and inorganic compounds from cattle-slaughterhouse wastewater.

  4. A NEW BIOGENIC SULFIDE CHEMICAL SENSOR FOR MARINE ENVIRONMENTAL MONITORING AND SURVEY

    Institute of Scientific and Technical Information of China (English)

    宋金明; 赵卫东

    2001-01-01

    A new convenient sulfide electrochemical sensor for marine environmental insitumonitoring and real time survey was developed. The new sensor based on a solid Ag2 S membrane electrode has outstanding chemical sensitivity and stability. It responds to the activity of sulfide ions according to a Nernsfian slope of - 31mV/decade. The sensor can be used to determine the total concentration of sulfides ( CT ) by calibrating the pH value of the solution to a standard pH. The practical measurement range for total sulfide concentration is 0.1 - 10 mg/L in seawater. The sensor has a very low potential drift ( < 4mV) during two months in 0.1 mg/L sulfide seawater. This paper describes the preparation of the sensitive membrane and some main properties of the sensor.

  5. A NEW BIOGENIC SULFIDE CHEMICAL SENSOR FOR MARINE ENVIRONMENTAL MONITORING AND SURVEY

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A new convenient sulfide electrochemical sensor for marine environmental in-situ monitoring and real time survey was developed. The new sensor based on a solid Ag2S membrane electrode has outstanding chemical sensitivity and stability. It responds to the activity of sulfide ions according to a Nernstian slope of -31mV/decade. The sensor can be used to determine the total concentration of sulfides (CT) by calibrating the pH value of the solution to a standard pH. The practical measurement range for total sulfide concentration is 0.1-10 mg/L in seawater. The sensor has a very low potential drift (<4mV) during two months in 0.1 mg/L sulfide seawater. This paper describes the preparation of the sensitive membrane and some main properties of the sensor.

  6. New Hydrodynamic Electrochemical Arrangement for Cadmium Ions Detection Using Thick-Film Chemical Sensor Electrodes

    Directory of Open Access Journals (Sweden)

    Rene Kizek

    2006-11-01

    Full Text Available Miniaturization and integration of chemical devices into modules that aredimensionally comparable with electronic chips (Lab on Chip is nowadays developingworldwide. The aim of our work was to suggest and optimize the best conditions forfabrication of TFT sensor due to its sensitivity and low experimental deviations. Newelectrochemical analytical device was developed to ensure certain known mass transport toelectrodes, which is the most limiting process that influencing the response quality of thesensor. The device consists from rotating conic vessel for measured sample and stick-inthick-film sensor. The sensors responses were tested under trace analysis of cadmium.Measurements were done also with the others electrochemical arrangements to comparewith the new one. The sensor output current response dependence on the liquid velocity andgeometrical arrangement within using standard electrochemical couple of potassiumferrocyanide-ferricyanide is presented. We found out that the new device with controlledflow of electrolyte to sensor worked properly and gave satisfactory results.

  7. MEMS Cantilever Sensor for THz Photoacoustic Chemical Sensing and Spectroscopy

    Science.gov (United States)

    2013-12-26

    event a chemical weapons attack, multiple detection units deployed around an air base could monitor the toxicity levels of the chemical agents. The...In the next step, the Ni seed layer exposed below the PMMA pattern is electroplated in a nickel sulfamate bath. Due to non-uniformity of the nickel ... chrome coating and AZ1518 photoresist options were used. The chrome metallization layer was 100 nm and the photoresist layer was 530 nm thick

  8. Combined Differential and Static Pressure Sensor based on a Double-Bridged Structure

    DEFF Research Database (Denmark)

    Pedersen, Casper; Jespersen, S.T.; Krog, J.P.

    2005-01-01

    . Output from the two bridges depends linearly on both differential and absolute (relative to atmospheric pressure) media pressure. Furthermore, the sensor stress distributions involved are studied by three-dimensional finite-element (FE) stress analysis. Furthermore, the FE analysis evaluates current......A combined differential and static silicon microelectromechanical system pressure sensor based on a double piezoresistive Wheatstone bridge structure is presented. The developed sensor has a conventional (inner) bridge on a micromachined diaphragm and a secondary (outer) bridge on the chip...... substrate. A novel approach is demonstrated with a combined measurement of outputs from the two bridges, which results in a combined deduction of both differential and static media pressure. Also following this new approach, a significant improvement in differential pressure sensor accuracy is achieved...

  9. Evaluation of chemical sensors for in situ ground-water monitoring at the Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, E.M.; Hostetler, D.D.

    1989-03-01

    This report documents a preliminary review and evaluation of instrument systems and sensors that may be used to detect ground-water contaminants in situ at the Hanford Site. Three topics are covered in this report: (1) identification of a group of priority contaminants at Hanford that could be monitored in situ, (2) a review of current instrument systems and sensors for environmental monitoring, and (3) an evaluation of instrument systems that could be used to monitor Hanford contaminants. Thirteen priority contaminants were identified in Hanford ground water, including carbon tetrachloride and six related chlorinated hydrocarbons, cyanide, methyl ethyl ketone, chromium (VI), fluoride, nitrate, and uranium. Based on transduction principles, chemical sensors were divided into four classes, ten specific types of instrument systems were considered: fluorescence spectroscopy, surface-enhanced Raman spectroscopy (SERS), spark excitation-fiber optic spectrochemical emission sensor (FOSES), chemical optrodes, stripping voltammetry, catalytic surface-modified ion electrode immunoassay sensors, resistance/capacitance, quartz piezobalance and surface acoustic wave devices. Because the flow of heat is difficult to control, there are currently no environmental chemical sensors based on thermal transduction. The ability of these ten instrument systems to detect the thirteen priority contaminants at the Hanford Site at the required sensitivity was evaluated. In addition, all ten instrument systems were qualitatively evaluated for general selectivity, response time, reliability, and field operability. 45 refs., 23 figs., 7 tabs.

  10. Chemically responsive nanoporous pigments: colorimetric sensor arrays and the identification of aliphatic amines.

    Science.gov (United States)

    Bang, Jin Ho; Lim, Sung H; Park, Erwin; Suslick, Kenneth S

    2008-11-18

    A general method has been developed for the preparation of microspheres of nanoporous pigments, their formulation into chemically responsive pigment inks, and the printing of these inks as colorimetric sensor arrays. Using an ultrasonic-spray aerosol-gel synthesis from chemically responsive dyes and common silica precursors, 16 different nanoporous pigment microspheres have been prepared and characterized. New colorimetric sensor arrays have been created by printing inks of these chemically responsive pigments as primary sensor elements; these arrays have been successfully tested for the detection, identification, and quantitation of toxic aliphatic amines. Among 11 structurally similar amines, complete identification of each analyte without confusion was achieved using hierarchical cluster analysis (HCA). Furthermore, visual identification of ammonia gas was easily made at the IDLH (immediately dangerous to life or health), PEL (permissible exposure limits), and 0.1 PEL concentrations with high reproducibility.

  11. Temperature-Insensitive Chemical Sensor with Twin Bragg Gratings in an Optical Fibre

    Institute of Scientific and Technical Information of China (English)

    SANG Xin-Zhu; YU Chong-Xiu; YAN Bin-Bin; MA Jian-Xin; MENG Zhao-Fang; Mayteevarunyoo T.; LU Nai-Guang

    2006-01-01

    To reduce temperature sensitivity of the fibre Bragg grating (FBG) chemical sensor, a simple method is proposed by measuring the peak wavelength difference between an etched FBG and an un-etched one in an optical fibre.Thermal characteristics and chemical sensitivity of the sensor are experimentally investigated. The experimental results indicate that the etched FBG and the rest one have almost the same thermal response, and concentration changes of the surrounding chemical solutions can be detected by measuring the peak wavelength difference between them. The sensor has been used to measure the concentrations of propylene glycol solutions and sugar solutions, and it could detect 0.7% and 0.45% concentration changes for them with an optical spectrum analyser in resolution of 10pm.

  12. Different sensing mechanisms in single wire and mat carbon nanotubes chemical sensors

    CERN Document Server

    Neumann, P L; Dobrik, G; Kertész, K; Horváth, E; Lukács, I E; Biró, L P; Horváth, Z E

    2014-01-01

    Chemical sensing properties of single wire and mat form sensor structures fabricated from the same carbon nanotube (CNT) materials have been compared. Sensing properties of CNT sensors were evaluated upon electrical response in the presence of five vapours as acetone, acetic acid, ethanol, toluene, and water. Diverse behaviour of single wire CNT sensors was found, while the mat structures showed similar response for all the applied vapours. This indicates that the sensing mechanism of random CNT networks cannot be interpreted as a simple summation of the constituting individual CNT effects, but is associated to another robust phenomenon, localized presumably at CNT-CNT junctions, must be supposed.

  13. New Potentiometric Wireless Chloride Sensors Provide High Resolution Information on Chemical Transport Processes in Streams

    Directory of Open Access Journals (Sweden)

    Keith Smettem

    2017-07-01

    Full Text Available Quantifying the travel times, pathways, and dispersion of solutes moving through stream environments is critical for understanding the biogeochemical cycling processes that control ecosystem functioning. Validation of stream solute transport and exchange process models requires data obtained from in-stream measurement of chemical concentration changes through time. This can be expensive and time consuming, leading to a need for cheap distributed sensor arrays that respond instantly and record chemical transport at points of interest on timescales of seconds. To meet this need we apply new, low-cost (in the order of a euro per sensor potentiometric chloride sensors used in a distributed array to obtain data with high spatial and temporal resolution. The application here is to monitoring in-stream hydrodynamic transport and dispersive mixing of an injected chemical, in this case NaCl. We present data obtained from the distributed sensor array under baseflow conditions for stream reaches in Luxembourg and Western Australia. The reaches were selected to provide a range of increasingly complex in-channel flow patterns. Mid-channel sensor results are comparable to data obtained from more expensive electrical conductivity meters, but simultaneous acquisition of tracer data at several positions across the channel allows far greater spatial resolution of hydrodynamic mixing processes and identification of chemical ‘dead zones’ in the study reaches.

  14. New Potentiometric Wireless Chloride Sensors Provide High Resolution Information on Chemical Transport Processes in Streams

    Science.gov (United States)

    Smettem, Keith; Harris, Nick; Cranny, Andy; Klaus, Julian; Pfister, Laurent

    2016-04-01

    Quantifying the travel times, pathways and dispersion of solutes moving through stream environments is critical for understanding the biogeochemical cycling processes that control ecosystem functioning. Validation of stream solute transport and exchange process models requires data obtained from in-stream measurement of chemical concentration changes through time. This can be expensive and time consuming, leading to a need for cheap distributed sensor arrays that respond instantly and record chemical transport at points of interest on timescales of seconds. To meet this need we apply new, low-cost (in the order of a euro per sensor) potentiometric chloride sensors used in a distributed array to obtain data with high spatial and temporal resolution. The application here is to monitoring in-stream hydrodynamic transport and dispersive mixing of an injected chemical, in this case NaCl. We present data obtained from the distributed sensor array under baseflow conditions for three stream reaches in Luxembourg. Sensor results are comparable to data obtained from more expensive electrical conductivity meters and allow spatial resolution of hydrodynamic mixing processes and identification of chemical 'dead zones' in the study reaches.

  15. Discodermolide analogues as the chemical component of combination bacteriolytic therapy.

    Science.gov (United States)

    Smith, Amos B; Freeze, B Scott; LaMarche, Matthew J; Sager, Jason; Kinzler, Kenneth W; Vogelstein, Bert

    2005-08-01

    The marine natural product (+)-discodermolide (1) and several simplified analogues of this microtubule-stabilizing agent have proven to be potent in vitro cell growth inhibitory agents in several human cancer cell lines. Here, we demonstrate the in vivo efficacy of discodermolide and several simplified congeners, both as stand-alone anti-tumor agents and, in the case of (+)-2,3-anhydrodiscodermolide (3), as a chemical component of the combination bacteriolytic therapy. A single intravenous injection of (+)-3 plus genetically modified Clostridium novyi-NT spores caused rapid and complete regressions of tumors in mice bearing HCT116 colorectal cancer xenografts.

  16. Detection in Urban Scenario Using Combined Airborne Imaging Sensors

    NARCIS (Netherlands)

    Renhorn, I.; Axelsson, M.; Benoist, K.W.; Bourghys, D.; Boucher, Y.; Xavier Briottet, X.; Sergio De CeglieD, S. De; Dekker, R.J.; Dimmeler, A.; Dost, R.; Friman, O.; Kåsen, I.; Maerker, J.; Persie, M. van; Resta, S.; Schwering, P.B.W.; Shimoni, M.; Vegard Haavardsholm, T.

    2012-01-01

    The EDA project “Detection in Urban scenario using Combined Airborne imaging Sensors” (DUCAS) is in progress. The aim of the project is to investigate the potential benefit of combined high spatial and spectral resolution airborne imagery for several defense applications in the urban area. The proje

  17. Detection in Urban Scenario using Combined Airborne Imaging Sensors

    NARCIS (Netherlands)

    Renhorn, I.; Axelsson, M.; Benoist, K.W.; Bourghys, D.; Boucher, Y.; Xavier Briottet, X.; Sergio De CeglieD, S. De; Dekker, R.J.; Dimmeler, A.; Dost, R.; Friman, O.; Kåsen, I.; Maerker, J.; Persie, M. van; Resta, S.; Schwering, P.B.W.; Shimoni, M.; Vegard Haavardsholm, T.

    2012-01-01

    The EDA project “Detection in Urban scenario using Combined Airborne imaging Sensors” (DUCAS) is in progress. The aim of the project is to investigate the potential benefit of combined high spatial and spectral resolution airborne imagery for several defense applications in the urban area. The proje

  18. Coagulation sensors based on magnetostrictive delay lines for biomedical and chemical engineering applications

    Energy Technology Data Exchange (ETDEWEB)

    Maliaritsi, E. [Laboratory of Physical Metallurgy, School of Mining and Metallurgy Engineering, National Technical University of Athens, Zografou Campus, Athens 15780 (Greece); Zoumpoulakis, L. [Laboratory of Materials Science and Technology, Inter-disciplinary Postgraduate Programme of NTUA, School of Chemical Engineering, National Technical University of Athens, Zografou Campus, 157 73 Athens (Greece); Simitzis, J. [Laboratory of Materials Science and Technology, Inter-disciplinary Postgraduate Programme of NTUA, School of Chemical Engineering, National Technical University of Athens, Zografou Campus, 157 73 Athens (Greece); Vassiliou, P. [Iaso General Hospital, Athens (Greece); Hristoforou, E. [Laboratory of Physical Metallurgy, School of Mining and Metallurgy Engineering, National Technical University of Athens, Zografou Campus, Athens 15780 (Greece)]. E-mail: eh@metal.ntua.gr

    2006-04-15

    Coagulation sensors based on the magnetostrictive delay line technique are presented in this paper. They are based on magnetostrictive ribbons and are used for measuring the coagulation, curing or solidification time of different liquids. Experimental results indicate that the presented sensing elements can determine the blood coagulation with remarkable repeatability, thus allowing their use as blood coagulation sensors. Additionally, results indicate that they can also measure curing time of resins, solidification of fluids and coagulation of chemical substances, therefore allowing their implementation in chemical engineering applications.

  19. Active hydrothermal and non-active massive sulfide mound investigation using a new multiparameter chemical sensor

    Science.gov (United States)

    Han, C.; Wu, G.; Qin, H.; Wang, Z.

    2012-12-01

    Investigation of active hydrothermal mound as well as non-active massive sulfide mound are studied recently. However, there is still lack of in-situ detection method for the non-active massive sulfide mound. Even though Transient ElectroMagnetic (TEM) and Electric Self-potential (SP) methods are good, they both are labour, time and money cost work. We proposed a new multiparameter chemical sensor method to study the seafloor active hydrothermal mound as well as non-active massive sulfide mound. This sensor integrates Eh, S2- ions concentration and pH electrochemical electrodes together, and could found chemical change caused by the active hydrothermal vent, even weak chemical abnormalities by non-active massive sulfide hydrothermal mound which MARP and CTD sometimes cannot detect. In 2012, the 1st Leg of the Chinese 26th cruise, the multiparameter chemical sensor was carried out with the deepsea camera system over the Carlsberg Ridge in Indian Ocean by R/V DAYANGYIHAO. It was shown small Eh and S2- ions concentration abnormal around a site at Northwest Indian ridge. This site was also evidenced by the TV grab. In the 2nd Leg of the same cruise in June, this chemical sensor was carried out with TEM and SP survey system. The chemical abnormalities are matched very well with both TEM and SP survey results. The results show that the multiparameter chemical sensor method not only can detect active hydrothermal mound, but also can find the non-active massive sulfide hydrothermal mound.

  20. Detection of Landmine Signature using SAW-based Polymer-coated Chemical Sensor

    Directory of Open Access Journals (Sweden)

    O. K. Kannan

    2004-07-01

    Full Text Available The explosive charge within a landmine is the source for a mixture of chemical vapours that form a distinctive chemical signature indicative of a landmine. The concentrations of these compounds in the air over landmines is extremely low (parts-per-trillion or lower, well below the minimum detection limits of most field-portable chemical sensors. This paper describes a portable  surface acoustic wave-based polymer-coated sensor for the detection of hidden explosives. The sensitivity and selectivity of polymer-based sensors depend on several factors including the chemo-selective coating used, the physical properties of the vapour(s of interest, the selected transducers, and the operating conditions. The polymer-based sensor was calibrated in the  laboratory using the explosive vapour generator. The preliminary results indicated that the carbowax 1000 could be a very good chemical interface to sense low levels of chemical signature of explosive material. Response for 50 ppb of TNT vapours was observed to be 400 Hz for an exposure of 2 min.

  1. Ultra-Trace Chemical Sensing with Long-Wave Infrared Cavity-Enhanced Spectroscopic Sensors

    Energy Technology Data Exchange (ETDEWEB)

    Taubman, Matthew S.; Myers, Tanya L.; Cannon, Bret D.; Williams, Richard M.; Schultz, John F.

    2003-02-20

    The infrared sensors task of Pacific Northwest National Laboratory's (PNNL's) Remote Spectroscopy Project (Task B of Project PL211) is focused on the science and technology of remote and in-situ spectroscopic chemical sensors for detecting proliferation and coun-tering terrorism. Missions to be addressed by remote chemical sensor development in-clude detecting proliferation of nuclear or chemical weapons, and providing warning of terrorist use of chemical weapons. Missions to be addressed by in-situ chemical sensor development include countering terrorism by screening luggage, personnel, and shipping containers for explosives, firearms, narcotics, chemical weapons, or chemical weapons residues, and mapping contaminated areas. The science and technology is also relevant to chemical weapons defense, air operations support, monitoring emissions from chemi-cal weapons destruction or industrial activities, law enforcement, medical diagnostics, and other applications. Sensors for most of these missions will require extreme chemical sensitivity and selectiv-ity because the signature chemicals of importance are expected to be present in low con-centrations or have low vapor pressures, and the ambient air is likely to contain pollutants or other chemicals with interfering spectra. Cavity-enhanced chemical sensors (CES) that draw air samples into optical cavities for laser-based interrogation of their chemical content promise real-time, in-situ chemical detection with extreme sensitivity to specified target molecules and superb immunity to spectral interference and other sources of noise. PNNL is developing CES based on quantum cascade (QC) lasers that operate in the mid-wave infrared (MWIR - 3 to 5 microns) and long-wave infrared (LWIR - 8 to 14 mi-crons), and CES based on telecommunications lasers operating in the short-wave infrared (SWIR - 1 to 2 microns). All three spectral regions are promising because smaller mo-lecular absorption cross sections in the SWIR

  2. Non-Contact Translation-Rotation Sensor Using Combined Effects of Magnetostriction and Piezoelectricity

    Directory of Open Access Journals (Sweden)

    Guang Meng

    2012-10-01

    Full Text Available Precise displacement sensors are an important topic in precision engineering. At present, this type of sensors typically have a single feature of either translation or rotation measurement. They are also inconvenient to integrate with the host devices. In this report we propose a new kind of sensor that enables both translation and rotation measurement by using the combined effect of magnetostriction and piezoelectricity. As a proof of concept, we experimentally realized a prototype of non-contact translation-rotation precise sensor. In the current research stage, through both theoretical and experimental study, the non-contact displacement sensor is shown to be feasible for measuring both translation and rotation either in coarse or fine measurement. Moreover, owing to its compact, rigid structure and fewer components, it can be easily embedded in host equipment.

  3. Non-contact translation-rotation sensor using combined effects of magnetostriction and piezoelectricity.

    Science.gov (United States)

    Yang, Bintang; Liu, Qingwei; Zhang, Ting; Cao, Yudong; Feng, Zhiqiang; Meng, Guang

    2012-10-15

    Precise displacement sensors are an important topic in precision engineering. At present, this type of sensors typically have a single feature of either translation or rotation measurement. They are also inconvenient to integrate with the host devices. In this report we propose a new kind of sensor that enables both translation and rotation measurement by using the combined effect of magnetostriction and piezoelectricity. As a proof of concept, we experimentally realized a prototype of non-contact translation-rotation precise sensor. In the current research stage, through both theoretical and experimental study, the non-contact displacement sensor is shown to be feasible for measuring both translation and rotation either in coarse or fine measurement. Moreover, owing to its compact, rigid structure and fewer components, it can be easily embedded in host equipment.

  4. Siberian Chemical Combine laboratory project work plan, fiscal year 1999

    Energy Technology Data Exchange (ETDEWEB)

    Morgado, R.E.; Acobyan, R.; Shropsire, R.

    1998-12-31

    The Siberian Chemical Combine (SKhK), Laboratory Project Work Plan (Plan) is intended to assist the US Laboratory Project Team, and Department of Energy (DOE) staff with the management of the FY99 joint material protection control and accounting program (MPC and A) for enhancing nuclear material safeguards within the Siberian Chemical Combine. The DOE/Russian/Newly Independent States, Nuclear Material Task Force, uses a project work plan document for higher-level program management. The SKhK Plan is a component of the Russian Defense related Sites` input to that document. In addition, it contains task descriptions and a Gantt Chart covering the FY99 time-period. This FY99 window is part of a comprehensive, Project Status Gantt Chart for tasking and goal setting that extends to the year 2003. Secondary and tertiary levels of detail are incorporated therein and are for the use of laboratory project management. The SKhK Plan is a working document, and additions and modifications will be incorporated as the MPC and A project for SKhK evolves.

  5. Paper-based chemical and biological sensors: Engineering aspects.

    Science.gov (United States)

    Ahmed, Snober; Bui, Minh-Phuong Ngoc; Abbas, Abdennour

    2016-03-15

    Remarkable efforts have been dedicated to paper-based chemosensors and biosensors over the last few years, mainly driven by the promise of reaching the best trade-off between performance, affordability and simplicity. Because of the low-cost and rapid prototyping of these sensors, recent research has been focused on providing affordable diagnostic devices to the developing world. The recent progress in sensitivity, multi-functionality and integration of microfluidic paper-based analytical devices (µPADs), increasingly suggests that this technology is not only attractive in resource-limited environments but it also represents a serious challenger to silicon, glass and polymer-based biosensors. This review discusses the design, chemistry and engineering aspects of these developments, with a focus on the past few years.

  6. Integrated optical sensors for 2D spatial chemical mapping (Conference Presentation)

    Science.gov (United States)

    Flores, Raquel; Janeiro, Ricardo; Viegas, Jaime

    2017-02-01

    Sensors based on optical waveguides for chemical sensing have attracted increasing interest over the last two decades, fueled by potential applications in commercial lab-on-a-chip devices for medical and food safety industries. Even though the early studies were oriented for single-point detection, progress in device size reduction and device yield afforded by photonics foundries have opened the opportunity for distributed dynamic chemical sensing at the microscale. This will allow researchers to follow the dynamics of chemical species in field of microbiology, and microchemistry, with a complementary method to current technologies based on microfluorescence and hyperspectral imaging. The study of the chemical dynamics at the surface of photoelectrodes in water splitting cells are a good candidate to benefit from such optochemical sensing devices that includes a photonic integrated circuit (PIC) with multiple sensors for real-time detection and spatial mapping of chemical species. In this project, we present experimental results on a prototype integrated optical system for chemical mapping based on the interaction of cascaded resonant optical devices, spatially covered with chemically sensitive polymers and plasmon-enhanced nanostructured metal/metal-oxide claddings offering chemical selectivity in a pixelated surface. In order to achieve a compact footprint, the prototype is based in a silicon photonics platform. A discussion on the relative merits of a photonic platform based on large bandgap metal oxides and nitrides which have higher chemical resistance than silicon is also presented.

  7. Online Decorrelation of Humidity and Temperature in Chemical Sensors for Continuous Monitoring

    CERN Document Server

    Huerta, Ramon; Fonollosa, Jordi; Rulkov, Nikolai F; Rodriguez-Lujan, Irene

    2016-01-01

    A method for online decorrelation of chemical sensor readings from the effects of environmental humidity and temperature variations is proposed. The goal is to improve the accuracy of electronic nose measurements for continuous monitoring by processing data from simultaneous readings of environmental humidity and temperature. The electronic nose setup built for this study included eight different metal-oxide sensors, temperature and humidity sensors with a wireless communication link to PC. This wireless electronic nose was used to monitor air for two years in the residence of one of the authors and collected data continuously during 510 full days with a sampling rate of 2 samples per second. To estimate the effects of variations in air humidity and temperature on the chemical sensors readings, we used a standard energy band model for an n-type metal-oxide sensor. The main assumption of the model is that variations in sensor conductivity can be expressed as a nonlinear function of changes in the semiconductor...

  8. Complementary Split-Ring Resonator-Loaded Microfluidic Ethanol Chemical Sensor

    Directory of Open Access Journals (Sweden)

    Ahmed Salim

    2016-10-01

    Full Text Available In this paper, a complementary split-ring resonator (CSRR-loaded patch is proposed as a microfluidic ethanol chemical sensor. The primary objective of this chemical sensor is to detect ethanol’s concentration. First, two tightly coupled concentric CSRRs loaded on a patch are realized on a Rogers RT/Duroid 5870 substrate, and then a microfluidic channel engraved on polydimethylsiloxane (PDMS is integrated for ethanol chemical sensor applications. The resonant frequency of the structure before loading the microfluidic channel is 4.72 GHz. After loading the microfluidic channel, the 550 MHz shift in the resonant frequency is ascribed to the dielectric perturbation phenomenon when the ethanol concentration is varied from 0% to 100%. In order to assess the sensitivity range of our proposed sensor, various concentrations of ethanol are tested and analyzed. Our proposed sensor exhibits repeatability and successfully detects 10% ethanol as verified by the measurement set-up. It has created headway to a miniaturized, non-contact, low-cost, reliable, reusable, and easily fabricated design using extremely small liquid volumes.

  9. Advances in SXFA-Coated SAW Chemical Sensors for Organophosphorous Compound Detection

    Directory of Open Access Journals (Sweden)

    Yong Pan

    2011-01-01

    Full Text Available A polymer-coated surface acoustic wave (SAW-based chemical sensor for organophosphorous compound sensing at extremely low concentrations was developed, in which a dual-delay-line oscillator coated with fluoroalcoholpolysiloxane (SXFA acted as the sensor element. Response mechanism analysis was performed on the SXFA-coated chemical sensor, resulting in the optimal design parameters. The shear modulus of the SXFA, which is the key parameter for theoretical simulation, was extracted experimentally. New designs were done on the SAW devices to decrease the insertion loss. Referring to the new phase modulation approach, superior short-term frequency stability (±2 Hz in seconds was achieved from the SAW oscillator using the fabricated 300 MHz delay line as the feedback element. In the sensor experiment on dimethylmethylphosphonate (DMMP detection, the fabricated SXFA-coated chemical sensor exhibited an excellent threshold detection limit up to 0.004 mg/m3 (0.7 ppb and good sensitivity (~485 Hz/mg/m3 for a DMMP concentration of 2~14 mg/m3.

  10. Advances in SXFA-coated SAW chemical sensors for organophosphorous compound detection.

    Science.gov (United States)

    Wang, Wen; He, Shitang; Li, Shunzhou; Liu, Minghua; Pan, Yong

    2011-01-01

    A polymer-coated surface acoustic wave (SAW)-based chemical sensor for organophosphorous compound sensing at extremely low concentrations was developed, in which a dual-delay-line oscillator coated with fluoroalcoholpolysiloxane (SXFA) acted as the sensor element. Response mechanism analysis was performed on the SXFA-coated chemical sensor, resulting in the optimal design parameters. The shear modulus of the SXFA, which is the key parameter for theoretical simulation, was extracted experimentally. New designs were done on the SAW devices to decrease the insertion loss. Referring to the new phase modulation approach, superior short-term frequency stability (±2 Hz in seconds) was achieved from the SAW oscillator using the fabricated 300 MHz delay line as the feedback element. In the sensor experiment on dimethylmethylphosphonate (DMMP) detection, the fabricated SXFA-coated chemical sensor exhibited an excellent threshold detection limit up to 0.004 mg/m(3) (0.7 ppb) and good sensitivity (∼485 Hz/mg/m(3) for a DMMP concentration of 2∼14 mg/m(3)).

  11. A comparison of minimum norm and MUSIC for a combined MEG/EEG sensor array

    Science.gov (United States)

    Ahrens, H.; Argin, F.; Klinkenbusch, L.

    2012-09-01

    Many different algorithms for imaging neuronal activity with magnetoencephalography (MEG) or electroencephalography (EEG) have been developed so far. We validate the result of other authors that a combined MEG/EEG sensor array provides smaller source localisation errors than a single MEG or single EEG sensor array for the same total number of sensors. We show that Multiple Signal Classification (MUSIC) provides smaller localisation errors than an unweighted minimum norm method for activity located in the cortical sulcus regions. This is important for many medical applications, e.g. the localisation of the origin of epileptic seizures (focal epilepsy) that can be located very deep in the cortical sulcus.

  12. A Method of Reducing Random Drift in the Combined Signal of an Array of Inertial Sensors

    Science.gov (United States)

    2015-09-30

    Invention [0003] The present invention relates to the components of inertial measurement units, sensors such as gyroscopes and accelerometers. More...METHOD OF REDUCING RANDOM DRIFT IN THE COMBINED SIGNAL OF AN ARRAY OF INERTIAL SENSORS STATEMENT OF GOVERNMENT INTEREST [0001] The invention described...royalties thereon or therefore. CROSS REFERENCE TO OTHER PATENT APPLICATIONS [0002] None. BACKGROUND OF THE INVENTION (1) Field of the

  13. Optimal Layout of Sensors on Wind Turbine Blade Based on Combinational Algorithm

    OpenAIRE

    Guimei Gu; Yu Zhao; Xin Zhang

    2016-01-01

    This work proposes a comprehensive combinational algorithm for sensor layout to solve the problem that unreasonable sensor layout affects the effectiveness of data selection and reduces the accuracy of monitoring system in healthy monitoring system of wind turbine blade structure. This algorithm integrates the advantages of kinetic energy method, effective independence method, modal assurance criterion (MAC), and many other optimal methods. In order to avoid information redundancy caused by p...

  14. B36 borophene as an electronic sensor for formaldehyde: Quantum chemical analysis

    Science.gov (United States)

    Shahbazi Kootenaei, Amirhossein; Ansari, Goodarz

    2016-08-01

    Pristine carbon nanotubes and graphene show great sensitivity toward several lethal gases but cannot identify some extremely toxic chemicals such as formaldehyde (HCOH). Recent successful synthesis of all-boron graphene-like sheets attracted strong interest in exploring their possible applications. Herein, we inspected the potential application of B36 borophene sheet as a sensor for HCOH detection, using density functional theory computations. Different theoretical levels including B97D and Minnesota 06 functionals with different basis sets were employed. It was predicted that the electrical conductivity of B36 borophene significantly increases at the presence of HCOH molecules, thereby generating an electrical signal. The electrical signal is increased by increasing the number of adsorbed HCOH molecules, indicating that this sensor is sensitive to the concentration (or pressure) of HCOH gas. These results suggest that the pristine borophene may be used in the HCOH chemical sensors.

  15. Highly sensitive surface plasmon resonance chemical sensor based on Goos-Hanchen effects

    Science.gov (United States)

    Yin, Xiaobo; Hesselink, Lambertus

    2006-08-01

    The resonance enhanced Goos-Hanchen shifts at attenuated total internal reflection enables the possibility for highly sensitive surface plasmon resonance sensor. The observed giant displacements result from the singular phase retardation at the resonance where the phase is continuous but changes dramatically. The phenomenon is proposed for chemical sensing and the superior sensitivity is demonstrated.

  16. Integrated label-free silicon nanowire sensor arrays for (bio)chemical analysis.

    Science.gov (United States)

    De, Arpita; van Nieuwkasteele, Jan; Carlen, Edwin T; van den Berg, Albert

    2013-06-07

    We present a label-free (bio)chemical analysis platform that uses all-electrical silicon nanowire sensor arrays integrated with a small volume microfluidic flow-cell for real-time (bio)chemical analysis and detection. The integrated sensing platform contains an automated multi-sample injection system that eliminates erroneous sensor responses from sample switching due to flow rate fluctuations and provides precise sample volumes down to 10 nl. Biochemical sensing is demonstrated with real-time 15-mer DNA-PNA (peptide nucleic acid) duplex hybridization measurements from different sample concentrations in a low ionic strength, and the equilibrium dissociation constant KD ≈ 140 nM has been extracted from the experimental data using the first order Langmuir binding model. Chemical sensing is demonstrated with pH measurements from different injected samples in flow that have sensitivities consistent with the gate-oxide materials. A differential sensor measurement configuration results in a 30× reduction in sensor drift. The integrated label-free analysis platform is suitable for a wide range of small volume chemical and biochemical analyses.

  17. Plastic Membrane Sensor from a Disposed Combined Glass Electrode

    Science.gov (United States)

    Marafie, Hayat M.; Shoukry, Adel F.; Alshatti, Laila A.

    2007-01-01

    The construction of combined plastic membrane electrode for hydralazinium cation from a disposed glass electrode is described. A variety of electrodes could be prepared by students using other types of polymers, plasticizers, or exchangers which could also help to study effects of pH and temperature, or environmental investigations.

  18. Combined spectroscopic and quantum chemical studies of ezetimibe

    Science.gov (United States)

    Prajapati, Preeti; Pandey, Jaya; Shimpi, Manishkumar R.; Srivastava, Anubha; Tandon, Poonam; Velaga, Sitaram P.; Sinha, Kirti

    2016-12-01

    Ezetimibe (EZT) is a hypocholesterolemic agent used for the treatment of elevated blood cholesterol levels as it lowers the blood cholesterol by blocking the absorption of cholesterol in intestine. Study aims to combine experimental and computational methods to provide insights into the structural and vibrational spectroscopic properties of EZT which is important for explaining drug substance physical and biological properties. Computational study on molecular properties of ezetimibe is presented using density functional theory (DFT) with B3LYP functional and 6-311++G(d,p) basis set. A detailed vibrational assignment has been done for the observed IR and Raman spectra of EZT. In addition to the conformational study, hydrogen bonding and molecular docking studies have been also performed. For conformational studies, the double well potential energy curves have been plotted for the rotation around the six flexible bonds of the molecule. UV absorption spectrum was examined in methanol solvent and compared with calculated one in solvent environment (IEF-PCM) using TD-DFT/6-31G basis set. HOMO-LUMO energy gap of both the conformers have also been calculated in order to predict its chemical reactivity and stability. The stability of the molecule was also examined by means of natural bond analysis (NBO) analysis. To account for the chemical reactivity and site selectivity of the molecules, molecular electrostatic potential (MEPS) map has been plotted. The combination of experimental and calculated results provide an insight into the structural and vibrational spectroscopic properties of EZT. In order to give an insight for the biological activity of EZT, molecular docking of EZT with protein NPC1L1 has been done.

  19. Chemical sensors based on surface-confined dendrimers

    Energy Technology Data Exchange (ETDEWEB)

    Tokuhisa, Hideo; Crooks, R.M. [Texas A& M Univ., College Station, TX (United States). Dept. of Chemistry; Ricco, A.J.; Osbourn, G.C. [Sandia National Labs., Albuquerque, NM (United States)

    1997-10-01

    The use of dendrimers for preparing chemically sensitive interfaces for detecting volatile organic compounds (VOCs) using surface acoustic wave (SAW) device transducers is described. Specifically, the synthesis of the dendrimers and the means by which they are affixed to SAW devices is discussed, followed by a detailed spectroscopic analysis of the surface-confined dendrimers and a discussion of their interaction with different VOCs. Most of these preliminary experiments focus on dendrimer surface modification using benzoylchloride, which leads to phenyl terminal groups linked to the dendrimer via amide groups. The results of this study lead us to conclude that dendrimers: (1) provide general specificity towards classes of functional groups and are therefore suitable for array-based sensing schemes; (2) are intermediate in structure between monolayers and polymers and exhibit the desirable properties of both; (3) can be straightforwardly attached to the surfaces of acoustic wave devices.

  20. Silicon chip integrated photonic sensors for biological and chemical sensing

    Science.gov (United States)

    Chakravarty, Swapnajit; Zou, Yi; Yan, Hai; Tang, Naimei; Chen, Ray T.

    2016-03-01

    We experimentally demonstrate applications of photonic crystal waveguide based devices for on-chip optical absorption spectroscopy for the detection of chemical warfare simulant, triethylphosphate as well as applications with photonic crystal microcavity devices in the detection of biomarkers for pancreatic cancer in patient serum and cadmium metal ions in heavy metal pollution sensing. At mid-infrared wavelengths, we experimentally demonstrate the higher sensitivity of photonic crystal based structures compared to other nanophotonic devices such as strip and slot waveguides with detection down to 10ppm triethylphosphate. We also detected 5ppb (parts per billion) of cadmium metal ions in water at near-infrared wavelengths using established techniques for the detection of specific probe-target biomarker conjugation chemistries.

  1. Combining multi-spectral proximal sensors and digital cameras for monitoring grazed tropical pastures

    Science.gov (United States)

    Handcock, R. N.; Gobbett, D. L.; González, L. A.; Bishop-Hurley, G. J.; McGavin, S. L.

    2015-11-01

    Timely and accurate monitoring of pasture biomass and ground-cover is necessary in livestock production systems to ensure productive and sustainable management of forage for livestock. Interest in the use of proximal sensors for monitoring pasture status in grazing systems has increased, since such sensors can return data in near real-time, and have the potential to be deployed on large properties where remote sensing may not be suitable due to issues such as spatial scale or cloud cover. However, there are unresolved challenges in developing calibrations to convert raw sensor data to quantitative biophysical values, such as pasture biomass or vegetation ground-cover, to allow meaningful interpretation of sensor data by livestock producers. We assessed the use of multiple proximal sensors for monitoring tropical pastures with a pilot deployment of sensors at two sites on Lansdown Research Station near Townsville, Australia. Each site was monitored by a Skye SKR-four-band multi-spectral sensor (every 1 min), a digital camera (every 30 min), and a soil moisture sensor (every 1 min), each operated over 18 months. Raw data from each sensor were processed to calculate a number of multispectral vegetation indices. Visual observations of pasture characteristics, including above-ground standing biomass and ground cover, were made every 2 weeks. A methodology was developed to manage the sensor deployment and the quality control of the data collected. The data capture from the digital cameras was more reliable than the multi-spectral sensors, which had up to 63 % of data discarded after data cleaning and quality control. We found a strong relationship between sensor and pasture measurements during the wet season period of maximum pasture growth (January to April), especially when data from the multi-spectral sensors were combined with weather data. RatioNS34 (a simple band ratio between the near infrared (NIR) and lower shortwave infrared (SWIR) bands) and rainfall since 1

  2. Development of High Temperature/High Sensitivity Novel Chemical Resistive Sensor

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chonglin; Nash, Patrick; Ma, Chunrui; Enriquez, Erik; Wang, Haibing; Xu, Xing; Bao, Shangyong; Collins, Gregory

    2013-08-13

    The research has been focused to design, fabricate, and develop high temperature/high sensitivity novel multifunctional chemical sensors for the selective detection of fossil energy gases used in power and fuel systems. By systematically studying the physical properties of the LnBaCo{sub 2}O{sub 5+d} (LBCO) [Ln=Pr or La] thin-films, a new concept chemical sensor based high temperature chemical resistant change has been developed for the application for the next generation highly efficient and near zero emission power generation technologies. We also discovered that the superfast chemical dynamic behavior and an ultrafast surface exchange kinetics in the highly epitaxial LBCO thin films. Furthermore, our research indicates that hydrogen can superfast diffuse in the ordered oxygen vacancy structures in the highly epitaxial LBCO thin films, which suggest that the LBCO thin film not only can be an excellent candidate for the fabrication of high temperature ultra sensitive chemical sensors and control systems for power and fuel monitoring systems, but also can be an excellent candidate for the low temperature solid oxide fuel cell anode and cathode materials.

  3. Accuracy of different sensors for the estimation of pollutant concentrations (total suspended solids, total and dissolved chemical oxygen demand) in wastewater and stormwater.

    Science.gov (United States)

    Lepot, Mathieu; Aubin, Jean-Baptiste; Bertrand-Krajewski, Jean-Luc

    2013-01-01

    Many field investigations have used continuous sensors (turbidimeters and/or ultraviolet (UV)-visible spectrophotometers) to estimate with a short time step pollutant concentrations in sewer systems. Few, if any, publications compare the performance of various sensors for the same set of samples. Different surrogate sensors (turbidity sensors, UV-visible spectrophotometer, pH meter, conductivity meter and microwave sensor) were tested to link concentrations of total suspended solids (TSS), total and dissolved chemical oxygen demand (COD), and sensors' outputs. In the combined sewer at the inlet of a wastewater treatment plant, 94 samples were collected during dry weather, 44 samples were collected during wet weather, and 165 samples were collected under both dry and wet weather conditions. From these samples, triplicate standard laboratory analyses were performed and corresponding sensors outputs were recorded. Two outlier detection methods were developed, based, respectively, on the Mahalanobis and Euclidean distances. Several hundred regression models were tested, and the best ones (according to the root mean square error criterion) are presented in order of decreasing performance. No sensor appears as the best one for all three investigated pollutants.

  4. Development of a Wireless and Passive SAW-Based Chemical Sensor for Organophosphorous Compound Detection

    Directory of Open Access Journals (Sweden)

    Fang-Qian Xu

    2015-12-01

    Full Text Available A new wireless and passive surface acoustic wave (SAW-based chemical sensor for organophosphorous compound (OC detection is presented. A 434 MHz reflective delay line configuration composed by single phase unidirectional transducers (SPUDTs and three shorted reflectors was fabricated on YZ LiNbO3 piezoelectric substrate as the sensor element. A thin fluoroalcoholpolysiloxane (SXFA film acted as the sensitive interface deposited onto the SAW propagation path between the second and last reflectors of the SAW device. The first reflector was used for the temperature compensation utilizing the difference method. The adsorption between the SXFA and OC molecules modulates the SAW propagation, especially for the time delay of the SAW, hence, the phase shifts of the reflection peaks from the corresponding reflectors can be used to characterize the target OC. Prior to the sensor fabrication, the coupling of modes (COM and perturbation theory were utilized to predict the SAW device performance and the gas adsorption. Referring to a frequency-modulated continuous wave (FMCW-based reader unit, the developed SAW chemical sensor was wirelessly characterized in gas exposure experiments for dimethylmethylphosphonate (DMMP detection. Sensor performance parameters such as phase sensitivity, repeatability, linearity, and temperature compensation were evaluated experimentally.

  5. Development of a Wireless and Passive SAW-Based Chemical Sensor for Organophosphorous Compound Detection.

    Science.gov (United States)

    Xu, Fang-Qian; Wang, Wen; Xue, Xu-Feng; Hu, Hao-Liang; Liu, Xin-Lu; Pan, Yong

    2015-12-03

    A new wireless and passive surface acoustic wave (SAW)-based chemical sensor for organophosphorous compound (OC) detection is presented. A 434 MHz reflective delay line configuration composed by single phase unidirectional transducers (SPUDTs) and three shorted reflectors was fabricated on YZ LiNbO₃ piezoelectric substrate as the sensor element. A thin fluoroalcoholpolysiloxane (SXFA) film acted as the sensitive interface deposited onto the SAW propagation path between the second and last reflectors of the SAW device. The first reflector was used for the temperature compensation utilizing the difference method. The adsorption between the SXFA and OC molecules modulates the SAW propagation, especially for the time delay of the SAW, hence, the phase shifts of the reflection peaks from the corresponding reflectors can be used to characterize the target OC. Prior to the sensor fabrication, the coupling of modes (COM) and perturbation theory were utilized to predict the SAW device performance and the gas adsorption. Referring to a frequency-modulated continuous wave (FMCW)-based reader unit, the developed SAW chemical sensor was wirelessly characterized in gas exposure experiments for dimethylmethylphosphonate (DMMP) detection. Sensor performance parameters such as phase sensitivity, repeatability, linearity, and temperature compensation were evaluated experimentally.

  6. Miniaturized, biopsy-implantable chemical sensor with wireless, magnetic resonance readout.

    Science.gov (United States)

    Vassiliou, C C; Liu, V H; Cima, M J

    2015-09-07

    Biopsy is an important diagnostic tool for a broad range of conditions. Cancer diagnoses, for example, are confirmed using tissue explanted with biopsy. Here we demonstrate a miniaturized wireless sensor that can be implanted during a biopsy procedure and return chemical information from within the body. Power and readout are wireless via weak magnetic resonant coupling to an external reader. The sensor is filled with responsive nuclear magnetic resonance (NMR) contrast agents for chemical sensitivity, and on-board circuitry constrains the NMR measurement to the contents. This sensor enables longitudinal monitoring of the same location, and its simple readout mechanism is ideal for applications not requiring the spatial information available through imaging techniques. We demonstrated the operation of this sensor by measuring two metabolic markers, both in vitro and in vivo: pH in flowing fluid for over 25 days and in a xenograft tumor model in mice, and oxygen in flowing gas and in a rat hind-limb constriction experiment. The results suggest that this in vivo sensing platform is generalizable to other available NMR contrast agents. These sensors have potential for use in biomedicine, environmental monitoring and quality control applications.

  7. Let's get Physiqual - An intuitive and generic method to combine sensor technology with ecological momentary assessments.

    Science.gov (United States)

    Blaauw, F J; Schenk, H M; Jeronimus, B F; van der Krieke, L; de Jonge, P; Aiello, M; Emerencia, A C

    2016-10-01

    The emergence of wearables and smartwatches is making sensors a ubiquitous technology to measure daily rhythms in physiological measures, such as movement and heart rate. An integration of sensor data from wearables and self-report questionnaire data about cognition, behaviors, and emotions can provide new insights into the interaction of mental and physiological processes in daily life. Hitherto no method existed that enables an easy-to-use integration of sensor and self-report data. To fill this gap, we present 'Physiqual', a platform for researchers that gathers and integrates data from commercially available sensors and service providers into one unified format for use in Ecological Momentary Assessments (EMA) or Experience Sampling Methods (ESM), and Quantified Self (QS). Physiqual currently supports sensor data provided by two well-known service providers and therewith a wide range of smartwatches and wearables. To demonstrate the features of Physiqual, we conducted a case study in which we assessed two subjects by means of data from an EMA study combined with sensor data as aggregated and exported by Physiqual. To the best of our knowledge, the Physiqual platform is the first platform that allows researchers to conveniently aggregate and integrate physiological sensor data with EMA studies.

  8. Annularly grooved membrane combined with rood beam piezoresistive pressure sensor for low pressure applications.

    Science.gov (United States)

    Li, Chuang; Cordovilla, Francisco; Ocaña, José L

    2017-03-01

    A novel structural piezoresistive pressure sensor with annularly grooved membrane combined with rood beam has been proposed for low pressure measurements based on silicon substrate. In this study, a design method, including the model design, dimensions optimization, and performance prediction of the novel structure sensor, is presented. The finite element method has been used to analyze the stress distribution of sensitive elements and the deflection of membrane. On the basis of simulation results, the relationships between structural dimension variables and mechanical performance are deduced, which make the fabrication processes more efficient. According to statistics theory, the coefficient of determination R(2) and residual sum of squares are introduced to indicate whether the fitting equations and curves match well with the simulation results. After that, a series of the optimal membrane dimensions are determined. Compared with other structural sensors, the optimized sensor achieves the best overall properties as it mitigates the contradiction between sensitivity and linearity. The reasons why the proposed sensor can maximize sensitivity and minimize nonlinearity are also discussed. By localizing more strain energy in the high concentrated stress profile and creating partially stiffened membrane, the proposed sensor has achieved a high sensitivity of 34.5 (mV/V)/psi and a low nonlinearity of 0.25% FSS. Thus, the proposed structure sensor will be a proper choice for low pressure applications less than 1 psi.

  9. Annularly grooved membrane combined with rood beam piezoresistive pressure sensor for low pressure applications

    Science.gov (United States)

    Li, Chuang; Cordovilla, Francisco; Ocaña, José L.

    2017-03-01

    A novel structural piezoresistive pressure sensor with annularly grooved membrane combined with rood beam has been proposed for low pressure measurements based on silicon substrate. In this study, a design method, including the model design, dimensions optimization, and performance prediction of the novel structure sensor, is presented. The finite element method has been used to analyze the stress distribution of sensitive elements and the deflection of membrane. On the basis of simulation results, the relationships between structural dimension variables and mechanical performance are deduced, which make the fabrication processes more efficient. According to statistics theory, the coefficient of determination R2 and residual sum of squares are introduced to indicate whether the fitting equations and curves match well with the simulation results. After that, a series of the optimal membrane dimensions are determined. Compared with other structural sensors, the optimized sensor achieves the best overall properties as it mitigates the contradiction between sensitivity and linearity. The reasons why the proposed sensor can maximize sensitivity and minimize nonlinearity are also discussed. By localizing more strain energy in the high concentrated stress profile and creating partially stiffened membrane, the proposed sensor has achieved a high sensitivity of 34.5 (mV/V)/psi and a low nonlinearity of 0.25% FSS. Thus, the proposed structure sensor will be a proper choice for low pressure applications less than 1 psi.

  10. Vehicle Classification and Speed Estimation Using Combined Passive Infrared/Ultrasonic Sensors

    KAUST Repository

    Odat, Enas

    2017-09-18

    In this paper, a new sensing device that can simultaneously monitor traffic congestion and urban flash floods is presented. This sensing device is based on the combination of passive infrared sensors (PIRs) and ultrasonic rangefinder, and is used for real-time vehicle detection, classification, and speed estimation in the context of wireless sensor networks. This framework relies on dynamic Bayesian Networks to fuse heterogeneous data both spatially and temporally for vehicle detection. To estimate the speed of the incoming vehicles, we first use cross correlation and wavelet transform-based methods to estimate the time delay between the signals of different sensors. We then propose a calibration and self-correction model based on Bayesian Networks to make a joint inference by all sensors about the speed and the length of the detected vehicle. Furthermore, we use the measurements of the ultrasonic and the PIR sensors to perform vehicle classification. Validation data (using an experimental dual infrared and ultrasonic traffic sensor) show a 99% accuracy in vehicle detection, a mean error of 5 kph in vehicle speed estimation, a mean error of 0.7m in vehicle length estimation, and a high accuracy in vehicle classification. Finally, we discuss the computational performance of the algorithm, and show that this framework can be implemented on low-power computational devices within a wireless sensor network setting. Such decentralized processing greatly improves the energy consumption of the system and minimizes bandwidth usage.

  11. Soft Sensor for Inputs and Parameters Using Nonlinear Singular State Observer in Chemical Processes

    Institute of Scientific and Technical Information of China (English)

    许锋; 汪晔晔; 罗雄麟

    2013-01-01

    Chemical processes are usually nonlinear singular systems. In this study, a soft sensor using nonlinear singular state observer is established for unknown inputs and uncertain model parameters in chemical processes, which are augmented as state variables. Based on the observability of the singular system, this paper presents a simplified observability criterion under certain conditions for unknown inputs and uncertain model parameters. When the observability is satisfied, the unknown inputs and the uncertain model parameters are estimated online by the soft sensor using augmented nonlinear singular state observer. The riser reactor of fluid catalytic cracking unit is used as an example for analysis and simulation. With the catalyst circulation rate as the only unknown input without model error, one temperature sensor at the riser reactor outlet will ensure the correct estimation for the catalyst cir-culation rate. However, when uncertain model parameters also exist, additional temperature sensors must be used to ensure correct estimation for unknown inputs and uncertain model parameters of chemical processes.

  12. B{sub 36} borophene as an electronic sensor for formaldehyde: Quantum chemical analysis

    Energy Technology Data Exchange (ETDEWEB)

    Shahbazi Kootenaei, Amirhossein, E-mail: a.kootenaei@gmail.com [Department of Chemical Engineering, Mahshahr Branch, Islamic Azad University, Mahshahr (Iran, Islamic Republic of); Ansari, Goodarz [Department of Chemistry, Mahshahr Branch, Islamic Azad University, Mahshahr (Iran, Islamic Republic of)

    2016-08-06

    Pristine carbon nanotubes and graphene show great sensitivity toward several lethal gases but cannot identify some extremely toxic chemicals such as formaldehyde (HCOH). Recent successful synthesis of all-boron graphene-like sheets attracted strong interest in exploring their possible applications. Herein, we inspected the potential application of B{sub 36} borophene sheet as a sensor for HCOH detection, using density functional theory computations. Different theoretical levels including B97D and Minnesota 06 functionals with different basis sets were employed. It was predicted that the electrical conductivity of B{sub 36} borophene significantly increases at the presence of HCOH molecules, thereby generating an electrical signal. The electrical signal is increased by increasing the number of adsorbed HCOH molecules, indicating that this sensor is sensitive to the concentration (or pressure) of HCOH gas. These results suggest that the pristine borophene may be used in the HCOH chemical sensors. - Highlights: • B{sub 36} borophene sheet can be used as a chemical sensor for HCOH detection. • The B{sub 36} is sensitive to the concentration of HCOH. • When the B{sub 36} adsorbs HCOH molecules, it is converted to a p-type semiconductor.

  13. A software-based sensor for combined sewer overflows.

    Science.gov (United States)

    Leonhardt, G; Fach, S; Engelhard, C; Kinzel, H; Rauch, W

    2012-01-01

    A new methodology for online estimation of excess flow from combined sewer overflow (CSO) structures based on simulation models is presented. If sufficient flow and water level data from the sewer system is available, no rainfall data are needed to run the model. An inverse rainfall-runoff model was developed to simulate net rainfall based on flow and water level data. Excess flow at all CSO structures in a catchment can then be simulated with a rainfall-runoff model. The method is applied to a case study and results show that the inverse rainfall-runoff model can be used instead of missing rain gauges. Online operation is ensured by software providing an interface to the SCADA-system of the operator and controlling the model. A water quality model could be included to simulate also pollutant concentrations in the excess flow.

  14. Chemical Contamination Sensor for Phosphate Ester Hydraulic Fluids

    Directory of Open Access Journals (Sweden)

    Sumit Paul

    2010-01-01

    Full Text Available The paper deals with chemical contamination monitoring in phosphate-ester-based hydraulic fluids using nondispersive infrared (NDIR optical absorption. Our results show that NDIR monitoring allows detecting the take-up of water into such fluids and their hydrolytic disintegration as these become additionally stressed by Joule heating. Observations on the O–H stretching vibration band (3200–3800 cm−1 are used for determining the free water content (0–1.5% and the Total Acid Number (0–1 mgKOH/g. Both quantities can be assessed by monitoring the strength and the asymmetry of the O–H vibration band with regard to the free water absorption band centred around 3500 cm−1. As such optical parameters can be assessed without taking fluid samples from a pressurised hydraulic system, fluid degradation trends can be established based on regular measurements, before irreversible damage to the fluid has occurred. Therefore maintenance actions can be planned accordingly, which is very important for the airline, as unscheduled maintenance disturbs the flights organisation and often generates money loss.

  15. Carbon Nanotubes as a chemical sensor: Six membered ring molecules

    Science.gov (United States)

    Sumanasekera, G. U.; Adu, C. K. A.; Pradhan, B. K.; Romero, H. E.; Eklund, P. C.

    2002-03-01

    The thermoelectric response of a mat of a carbon nanotubes has been shown to be sensitive to the details of the molecule-SWNT interaction. In this presentation, we consider the effects of the adsorption of the six-membered-ring hydrocarbon molecules with varying π electron population (C_6H_n; n=6,8,10,12), heteroatoms (N), and adducts, etc. A wide variety of the thermoelectric response to these similar molecules is observed. For example, adsorption of Benzene (n=6) induces a giant increase of the thermopower, even reversing the sign. As the π electrons of the molecule are removed (i.e., increasing hydrogenation), the effect disapears. Thus, a selective chemical response is observed. The phenomenon is identied with scattering driven by the coupling of the π electrons in the molecule and the nanotube wall. Pyridine, on the otherhand, drives the thermopower more negative, and decreases the resistivity, suggesting charge transfer between nanotube and adsorbed molecule. Work supported by ONR # N00014-99-1-0619

  16. Gravimetric chemical sensors based on silica-based mesoporous organic-inorganic hybrids.

    Science.gov (United States)

    Xu, Jiaqiang; Zheng, Qi; Zhu, Yongheng; Lou, Huihui; Xiang, Qun; Cheng, Zhixuan

    2014-09-01

    Silica-based mesoporous organic-inorganic hybrid material modified quartz crystal microbalance (QCM) sensors have been examined for their ability to achieve highly sensitive and selective detection. Mesoporous silica SBA-15 serves as an inorganic host with large specific surface area, facilitating gas adsorption, and thus leads to highly sensitive response; while the presence of organic functional groups contributes to the greatly improved specific sensing property. In this work, we summarize our efforts in the rational design and synthesis of novel sensing materials for the detection of hazardous substances, including simulant nerve agent, organic vapor, and heavy metal ion, and develop high-performance QCM-based chemical sensors.

  17. Surface plasmon resonance based fibre optic chemical sensor for the detection of cocaine

    Science.gov (United States)

    Nguyen, T. Hien; Sun, Tong; Grattan, Kenneth T. V.

    2016-05-01

    A surface plasmon based fibre-optic chemical sensor for the detection of cocaine has been developed using a molecularly imprinted polymer (MIP) film with embedded gold nanoparticles as the recognition element. The MIP was formed on the layer of gold thin film which was deposited on the surface of a fibre core. The sensing was based on swelling of the MIP film induced by analyte binding that shifted the resonance spectrum toward a shorter wavelength. The sensor exhibited a response to cocaine in the concentration range of 0 - 400 μM in aqueous acetonitrile mixtures. Selectivity for cocaine over other drugs has also been demonstrated.

  18. Microstructured and Photonic Bandgap Fibers for Applications in the Resonant Bio- and Chemical Sensors

    Directory of Open Access Journals (Sweden)

    Maksim Skorobogatiy

    2009-01-01

    Full Text Available We review application of microstructured and photonic bandgap fibers for designing resonant optical sensors of changes in the value of analyte refractive index. This research subject has recently invoked much attention due to development of novel fiber types, as well as due to development of techniques for the activation of fiber microstructure with functional materials. Particularly, we consider two sensors types. The first sensor type employs hollow core photonic bandgap fibers where core guided mode is confined in the analyte filled core through resonant effect in the surrounding periodic reflector. The second sensor type employs metalized microstructured or photonic bandgap waveguides and fibers, where core guided mode is phase matched with a plasmon propagating at the fiber/analyte interface. In resonant sensors one typically employs fibers with strongly nonuniform spectral transmission characteristics that are sensitive to changes in the real part of the analyte refractive index. Moreover, if narrow absorption lines are present in the analyte transmission spectrum, due to Kramers-Kronig relation this will also result in strong variation in the real part of the refractive index in the vicinity of an absorption line. Therefore, resonant sensors allow detection of minute changes both in the real part of the analyte refractive index (10−6–10−4 RIU, as well as in the imaginary part of the analyte refractive index in the vicinity of absorption lines. In the following we detail various resonant sensor implementations, modes of operation, as well as analysis of sensitivities for some of the common transduction mechanisms for bio- and chemical sensing applications. Sensor designs considered in this review span spectral operation regions from the visible to terahertz.

  19. Positioning sensor by combining optical projection and photogrammetry

    Science.gov (United States)

    Zheng, Benrui

    Six spatial parameters, (x, y, z) for translation, and pitch, roll, and yaw for rotation, are used to describe the 3-dimensional position and orientation of a rigid body---the 6 degrees of freedom (DOF). The ability to measure these parameters is required in a diverse range of applications including machine tool metrology, robot calibration, motion control, motion analysis, and reconstructive surgery. However, there are limitations associated with the currently available measurement systems. Shortcomings include some of the following: short dynamic range, limited accuracy, line of sight restrictions, and capital cost. The objective of this dissertation was to develop a new metrology system that overcomes line of sight restrictions, reduces system costs, allows large dynamic range and has the potential to provide high measurement accuracy. The new metrology system proposed in this dissertation is based on a combination of photogrammetry and optical pattern projection. This system has the potential to enable real-time measurement of a small lightweight module's location. The module generates an optical pattern that is observable on the surrounding walls, and photogrammetry is used to measure the absolute coordinates of features in the projected optical pattern with respect to a defined global coordinate system. By combining these absolute coordinates with the known angular information of the optical projection beams, a minimization algorithm can be used to extract the absolute coordinates and angular orientation of the module itself. The feasibility of the proposed metrology system was first proved through preliminary experimental tests. By using a module with a 7x7 dot matrix pattern, experimental agreement of 1 to 5 parts in 103 was obtained by translating the module over 0.9 m and by rotating it through 60°. The proposed metrology system was modeled through numerical simulations and factors affecting the uncertainty of the measurement were investigated. The

  20. Inactivation of enteric microorganisms with chemical disinfectants, UV irradiation and combined chemical/UV treatments.

    Science.gov (United States)

    Koivunen, J; Heinonen-Tanski, H

    2005-04-01

    The relative disinfection efficiencies of peracetic acid (PAA), hydrogen peroxide (H2O2) and sodium hypochlorite (NaOCl) against Escherichia coli, Enterococcus faecalis, Salmonella enteritidis and coliphage MS2 virus were studied in laboratory-scale experiments. This study also evaluated the efficiency of combined PAA/ultraviolet irradiation (UV) and H2O2/UV treatments to determine if the microbial inactivation was synergistic. Microbial cultures were added into a synthetic wastewater-like test medium and treated by chemical disinfectants with a 10 min contact time, UV irradiation or the combination of chemical and UV treatments. A peracetic acid dose of 3 mg/l resulted in approximately 2-3 log enteric bacterial reductions, whereas 7-15 mg/l PAA was needed to achieve 1-1.5 log coliphage MS2 reductions. Doses of 3-150 mg/l hydrogen peroxide achieved below 0.2 log microbial reductions. Sodium hypochlorite treatments caused 0.3-1 log microbial reductions at an 18 mg/l chlorine dose, while 2.6 log reductions of E. faecalis were achieved at a 12 mg/l chlorine dose. The results indicate that PAA could represent a good alternative to chlorine compounds in disinfection procedures, especially in wastewaters containing easily oxidizable organic matter. Hydrogen peroxide is not an efficient disinfectant against enteric microorganisms in wastewaters. The combined PAA/UV disinfection showed increased disinfection efficiency and synergistic benefits with all the enteric bacteria tested but lower synergies for the coliphage MS2. This suggests that this method could improve the efficiency and reliability of disinfection in wastewater treatment plants. The combined H2O2/UV disinfection only slightly influenced the microbial reductions compared to UV treatments and showed some antagonism and no synergies.

  1. A simple network agreement-based approach for combining evidences in a heterogeneous sensor network

    Directory of Open Access Journals (Sweden)

    Raúl Eusebio-Grande

    2015-12-01

    Full Text Available In this research we investigate how the evidences provided by both static and mobile nodes that are part of a heterogenous sensor network can be combined to have trustworthy results. A solution relying on a network agreement-based approach was implemented and tested.

  2. Development and characterization of electrochemical cantilever sensor for bio/chemical sensing applications

    DEFF Research Database (Denmark)

    Quan, Xueling; Fischer, Lee MacKenzie; Boisen, Anja

    2011-01-01

    We report the improvements made to our previously developed electrochemical cantilever (EC) sensor, where nanoporous gold material is employed as working electrodes in microcantilever arrays, while combined counter-reference electrodes are integrated on the chip. For a surface stress change of 1m...

  3. Low Pass Filter Model for Chemical Sensors in Response to Gases and Odors

    Directory of Open Access Journals (Sweden)

    Mahmoud Z. Iskandarani

    2012-01-01

    Full Text Available Design and Modeling multi-gap sensing odor system for the objectives of odor recognition, classification and correlation are carried out. The model illustrates the low pass functionality of the multi-gap sensor acting as a filter for odors. Problem statement: Odor filtering is an important issue in today's world. In addition knowing the original material that an odor belongs to even after being mixed with others is also of vital importance. In addition measuring quality of mixed odors in terms of their affinity and belonging to a specific category or is critical. Approach: Mathematical modeling using low pass filter is carried out. Results: Clear evidence of ability to filter components of an odor mixture as the multi-gap sensor is acting as a filter. Conclusion: The ability to custom design chemical sensors to indicate the presence of various odors.

  4. Recent advances in gas and chemical detection by Vernier effect-based photonic sensors.

    Science.gov (United States)

    La Notte, Mario; Troia, Benedetto; Muciaccia, Tommaso; Campanella, Carlo Edoardo; De Leonardis, Francesco; Passaro, Vittorio M N

    2014-03-10

    Recently, the Vernier effect has been proved to be very efficient for significantly improving the sensitivity and the limit of detection (LOD) of chemical, biochemical and gas photonic sensors. In this paper a review of compact and efficient photonic sensors based on the Vernier effect is presented. The most relevant results of several theoretical and experimental works are reported, and the theoretical model of the typical Vernier effect-based sensor is discussed as well. In particular, sensitivity up to 460 μm/RIU has been experimentally reported, while ultra-high sensitivity of 2,500 μm/RIU and ultra-low LOD of 8.79 × 10(-8) RIU have been theoretically demonstrated, employing a Mach-Zehnder Interferometer (MZI) as sensing device instead of an add drop ring resonator.

  5. Recent Advances in Gas and Chemical Detection by Vernier Effect-Based Photonic Sensors

    Directory of Open Access Journals (Sweden)

    Mario La Notte

    2014-03-01

    Full Text Available Recently, the Vernier effect has been proved to be very efficient for significantly improving the sensitivity and the limit of detection (LOD of chemical, biochemical and gas photonic sensors. In this paper a review of compact and efficient photonic sensors based on the Vernier effect is presented. The most relevant results of several theoretical and experimental works are reported, and the theoretical model of the typical Vernier effect-based sensor is discussed as well. In particular, sensitivity up to 460 μm/RIU has been experimentally reported, while ultra-high sensitivity of 2,500 μm/RIU and ultra-low LOD of 8.79 × 10−8 RIU have been theoretically demonstrated, employing a Mach-Zehnder Interferometer (MZI as sensing device instead of an add drop ring resonator.

  6. Combined Dynamic Time Warping with Multiple Sensors for 3D Gesture Recognition.

    Science.gov (United States)

    Choi, Hyo-Rim; Kim, TaeYong

    2017-08-17

    Cyber-physical systems, which closely integrate physical systems and humans, can be applied to a wider range of applications through user movement analysis. In three-dimensional (3D) gesture recognition, multiple sensors are required to recognize various natural gestures. Several studies have been undertaken in the field of gesture recognition; however, gesture recognition was conducted based on data captured from various independent sensors, which rendered the capture and combination of real-time data complicated. In this study, a 3D gesture recognition method using combined information obtained from multiple sensors is proposed. The proposed method can robustly perform gesture recognition regardless of a user's location and movement directions by providing viewpoint-weighted values and/or motion-weighted values. In the proposed method, the viewpoint-weighted dynamic time warping with multiple sensors has enhanced performance by preventing joint measurement errors and noise due to sensor measurement tolerance, which has resulted in the enhancement of recognition performance by comparing multiple joint sequences effectively.

  7. Smart Sensor for Online Detection of Multiple-Combined Faults in VSD-Fed Induction Motors

    Science.gov (United States)

    Garcia-Ramirez, Armando G.; Osornio-Rios, Roque A.; Granados-Lieberman, David; Garcia-Perez, Arturo; Romero-Troncoso, Rene J.

    2012-01-01

    Induction motors fed through variable speed drives (VSD) are widely used in different industrial processes. Nowadays, the industry demands the integration of smart sensors to improve the fault detection in order to reduce cost, maintenance and power consumption. Induction motors can develop one or more faults at the same time that can be produce severe damages. The combined fault identification in induction motors is a demanding task, but it has been rarely considered in spite of being a common situation, because it is difficult to identify two or more faults simultaneously. This work presents a smart sensor for online detection of simple and multiple-combined faults in induction motors fed through a VSD in a wide frequency range covering low frequencies from 3 Hz and high frequencies up to 60 Hz based on a primary sensor being a commercially available current clamp or a hall-effect sensor. The proposed smart sensor implements a methodology based on the fast Fourier transform (FFT), RMS calculation and artificial neural networks (ANN), which are processed online using digital hardware signal processing based on field programmable gate array (FPGA).

  8. Chemical pretreatment of combined sewer overflows for improved UV disinfection.

    Science.gov (United States)

    Gibson, J; Farnood, R; Seto, P

    2016-01-01

    The aim of this research was to better understand chemical pre-treatment of combined sewer overflows (CSOs) for subsequent ultraviolet (UV) disinfection. Approximately 200 jar tests were completed. Alum (Al2(S04)3·12H2O) resulted in a higher UV light transmission (UVT), and equivalent total suspended solids (TSS) removal, than ferric chloride (FeCl3). An alum dose of 20 mg/L increased the UVT of the raw CSO from 30 to 60% after settling. The addition of 100 mg/L of alum maximized UVT reaching approximately 85%. Flocculation did not increase UVT. However, it did improve the removal of TSS. Cationic polymers worked quickly compared with metal coagulants, but only reached a UVT of 60%. A high positive charge density on the polymer improved the removal of turbidity when compared with low charge, but did not affect UVT. If the goal is to maximise UVT, a very high alum dose may be preferred. If the goal is to minimize coagulant dose with moderate UV performance, cationic polymer at approximately 3 mg/L is recommended.

  9. pH-responsive fluorescence chemical sensor constituted by conjugated polymers containing pyridine rings.

    Science.gov (United States)

    Adachi, Naoya; Kaneko, Yuki; Sekiguchi, Kazuki; Sugiyama, Hiroki; Sugeno, Masafumi

    2015-12-01

    Poly(p-pyridinium phenylene ethynylene)s (PPyPE) functionalized with alternating donor-acceptor repeat units were synthesized by a Pd-catalyzed Sonogashira coupling reaction between diethynyl monomer and di-iodopyridine for use as a pH-responsive fluorescence chemical sensor. The synthesized PPyPE, containing pyridine units, was characterized by FT-IR, (1)H and (13)C NMR, UV-visible and fluorescence spectroscopies. We investigated the relationship between changes of optical properties and protonation/deprotonation of PPyPE containing pyridine units in solution. Addition of HCl decreased and red-shifted the fluorescence intensity of the conjugated polymers that contained pyridine rings; fluorescence intensity of the polymers increased upon addition of NaOH solution. The synthesized PPyPE was found to be an effective and reusable chemical sensor for pH sensing.

  10. A progress report on the LDRD project entitled {open_quotes}Microelectronic silicon-based chemical sensors: Ultradetection of high value molecules{close_quotes}

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, R.C.

    1996-09-01

    This work addresses a new kind of silicon based chemical sensor that combines the reliability and stability of silicon microelectronic field effect devices with the highly selective and sensitive immunoassay. The sensor works on the principle that thin SiN layers on lightly doped Si can detect pH changes rapidly and reversibly. The pH changes affect the surface potential, and that can be quickly determined by pulsed photovoltage measurements. To detect other species, chemically sensitive films were deposited on the SiN where the presence of the chosen analyte results in pH changes through chemical reactions. A invention of a cell sorting device based on these principles is also described. A new method of immobilizing enzymes using Sandia`s sol-gel glasses is documented and biosensors based on the silicon wafer and an amperometric technique are detailed.

  11. A Low-Noise DC seismic accelerometer based on a combination of MET/MEMS sensors.

    Science.gov (United States)

    Neeshpapa, Alexander; Antonov, Alexander; Agafonov, Vadim

    2014-12-26

    Molecular-electronic transducers (MET) have a high conversion coefficient and low power consumption, and do not require precision mechanical components thus allowing the construction of cost- and power-efficient seismic accelerometers. Whereas the instrumental resolution of a MET accelerometer within the 0.1-100 Hz frequency range surpasses that of the best Micro-Electro Mechanical Systems (MEMS) and even some force-balanced accelerometers, the fundamental inability to register gravity or, in other words, zero frequency acceleration, significantly constrains the further spread of MET-based accelerometers. Ways of obviating this inherent zero frequency insensitivity within MET technology have so far, not been found. This article explores a possible approach to the construction of a hybrid seismic accelerometer combining the superb performance of a MET sensor in the middle and high frequency range with a conventional on chip MEMS accelerometer covering the lower frequencies and gravity. Though the frequency separation of a signal is widely used in various applications, the opposite task, i.e., the combining of two signals with different bandwidths is less common. Based on theoretical research and the analysis of actual sensors' performance, the authors determined optimal parameters for building a hybrid sensor. Description and results for implementation of the hybrid sensor are given in the Experimental section of the article. Completing a MET sensor with a cost-effective MEMS permitted the construction of a low noise DC accelerometer preserving the noise performance of a MET sensing element. The work presented herein may prove useful in designing other combined sensors based on different technologies.

  12. Chemical sensors for classification of mine-like objects by identification of explosives

    Energy Technology Data Exchange (ETDEWEB)

    Woodfin, R.L.

    1997-10-01

    This paper briefly describes a prototype sensor for detecting land mines placed in shallow water. An automatic system was developed which incorporates chemical concentration technology, an ion mobility spectrometer, and control and fluid movement subsystems. The system design was successfully demonstrated using laboratory instruments and equipment. Components for the portable unit, which will weigh less than 20 pounds, have been fabricated; field demonstrations will be completed by spring 1998. 4 figs.

  13. Chemical Sensor Platform for Non-Invasive Monitoring of Activity and Dehydration

    Directory of Open Access Journals (Sweden)

    Dmitry Solovei

    2015-01-01

    Full Text Available A non-invasive solution for monitoring of the activity and dehydration of organisms is proposed in the work. For this purpose, a wireless standalone chemical sensor platform using two separate measurement techniques has been developed. The first approach for activity monitoring is based on humidity measurement. Our solution uses new humidity sensor based on a nanostructured TiO2 surface for sweat rate monitoring. The second technique is based on monitoring of potassium concentration in urine. High level of potassium concentration denotes clear occurrence of dehydration. Furthermore, a Wireless Body Area Network (WBAN was developed for this sensor platform to manage data transfer among devices and the internet. The WBAN coordinator controls the sensor devices and collects and stores the measured data. The collected data is particular to individuals and can be shared with physicians, emergency systems or athletes’ coaches. Long-time monitoring of activity and potassium concentration in urine can help maintain the appropriate water intake of elderly people or athletes and to send warning signals in the case of near dehydration. The created sensor system was calibrated and tested in laboratory and real conditions as well. The measurement results are discussed.

  14. Intrinsic Fabry-Perot Interferometeric Sensor Based on Microfiber Created by Chemical Etching

    Directory of Open Access Journals (Sweden)

    Ruohui Wang

    2014-09-01

    Full Text Available An intrinsic Fabry-Perot interferometeric sensor based on a microfiber has been demonstrated. The micro-size suspended core is created by chemical etching a photonics crystal fiber, of which the cladding has a micrometer-spaced, hexagonal array of air holes. The sensing head is fabricated by chemical etching a short section of photonics crystal fiber spliced with a single mode fiber. The temperature sensing characteristic of the interferometer has also been demonstrated and a sensitivity 14.3 pm/°C is obtained.

  15. A Compact, Low-Power Cantilever-Based Sensor Array for Chemical Detection

    Energy Technology Data Exchange (ETDEWEB)

    Loui, A; Ratto, T; Wilson, T; Mukerjee, E; Hu, Z; Sulchek, T; Hart, B

    2007-02-22

    A compact and low-power cantilever-based sensor array has been developed and used to detect various vapor analytes. This device employs sorptive polymers that are deposited onto piezoresistive cantilevers. We have successfully detected several organic vapors, representing a breadth of chemical properties and over a range of concentrations. Comparisons of the polymer/vapor partition coefficient to the cantilever deflection responses show that a simple linear relationship does not exist, emphasizing the need to develop an appropriate functional model to describe the chemical-to-mechanical transduction that is unique to this sensing modality.

  16. Denoising of human speech using combined acoustic and em sensor signal processing

    Energy Technology Data Exchange (ETDEWEB)

    Ng, L C; Burnett, G C; Holzrichter, J F; Gable, T J

    1999-11-29

    Low Power EM radar-like sensors have made it possible to measure properties of the human speech production system in real-time, without acoustic interference. This greatly enhances the quality and quantify of information for many speech related applications. See Holzrichter, Burnett, Ng, and Lea, J. Acoustic. Soc. Am. 103 (1) 622 (1998). By using combined Glottal-EM- Sensor- and Acoustic-signals, segments of voiced, unvoiced, and no-speech can be reliably defined. Real-time Denoising filters can be constructed to remove noise from the user's corresponding speech signal.

  17. Development of Magnetically Excited Flexural Plate Wave Devices for Implementation as Physical, Chemical, and Acoustic Sensors, and as Integrated Micro-Pumps for Sensored Systems

    Science.gov (United States)

    Schubert, W. K.; Mitchell, M. A.; Graf, D. C.; Shul, R. J.

    2002-05-01

    The magnetically excited flexural plate wave (mag-FPW) device has great promise as a versatile sensor platform. FPW's can have better sensitivity at lower operating frequencies than surface acoustic wave (SAW) devices. Lower operating frequency simplifies the control electronics and makes integration of sensor with electronics easier. Magnetic rather than piezoelectric excitation of the FPW greatly simplifies the device structure and processing by eliminating the need for piezoelectric thin films, also simplifying integration issues. The versatile mag-FPW resonator structure can potentially be configured to fulfill a number of critical functions in an autonomous sensored system. As a physical sensor, the device can be extremely sensitive to temperature, fluid flow, strain, acceleration and vibration. By coating the membrane with self-assembled monolayers (SAMs), or polymer films with selective absorption properties (originally developed for SAW sensors), the mass sensitivity of the FPW allows it to be used as biological or chemical sensors. Yet another critical need in autonomous sensor systems is the ability to pump fluid. FPW structures can be configured as micro-pumps. This report describes work done to develop mag-FPW devices as physical, chemical, and acoustic sensors, and as micro-pumps for both liquid and gas-phase analytes to enable new integrated sensing platform.

  18. High Sensitivity, Low Power Nano Sensors and Devices for Chemical Sensing

    Science.gov (United States)

    Li, Jing; Powell, Dan; Getty, Stephanie; Lu, Yi-Jiang

    2004-01-01

    The chemical sensor market has been projected to grow to better than $40 billion dollars worldwide within the next 10 years. Some of the primary motivations to develop nanostructured chemical sensors are monitoring and control of environmental pollution; improved diagnostics for consumption; improvement in measurement precision and accuracy; and improved detection limits for Homeland security, battlefield environments, and process and quality control of industrial applications. In each of these applications, there is demand for sensitivity, selectivity and stability of environmental and biohazard detection and capture beyond what is currently commercially available. Nanotechnology offers the ability to work at the molecular level, atom by atom, to create large structures with fundamentally new molecular organization. It is essentially concerned with materials, devices, and systems whose structures and components exhibit novel and significantly improved physical, chemical and biological properties, phenomena, and process control due to their nanoscale size. One such nanotechnology-enabled chemical sensor has been developed at NASA Ames leveraging nanostructures, such as single walled carbon nanotubes (SWNTs) and metal oxide nanobelts or nanowires, as a sensing medium bridging a pair of interdigitated electrodes (IDE) realized through a silicon-based microfabrication and micromachining technique. The DE fingers are fabricated on a silicon substrate using standard photolithography and thin film metallization techniques. It is noteworthy that the fabrication techniques employed are not confined to the silicon substrate. Through spin casting and careful substrate selection (i.e. clothing, glass, polymer, etc.), additional degrees of freedom can be exploited to enhance sensitivity or to conform to unique applications. Both in-situ growth of nanostructured materials and casting of nanostructured dispersions were used to produce analogous chemical sensing devices.

  19. Assessment of diffusion parameters of new passive samplers using optical chemical sensor for on-site measuring formaldehyde in indoor air: experimental and numerical studies.

    Science.gov (United States)

    Vignau-Laulhere, Jane; Mocho, Pierre; Plaisance, Hervé; Raulin, Katarzyna; Desauziers, Valérie

    2016-03-01

    New passive samplers using a sensor consisting of a sol-gel matrix entrapping Fluoral-P as sampling media were developed for the determination of formaldehyde in indoor air. The reaction between Fluoral-P and formaldehyde produces a colored compound which is quantified on-site by means of a simple optical reading module. The advantages of this sensor are selectivity, low cost, ppb level limit of detection, and on-site direct measurement. In the development process, it is necessary to determine the sampling rate, a key parameter that cannot be directly assessed in the case of diffusive samplers using optical chemical sensor. In this study, a methodology combining experimental tests and numerical modeling is proposed and applied at five different radial diffusive samplers equipped with the same optical chemical sensor to assess the sampled material flows and sampling rates. These radial diffusive samplers differ in the internal volume of the sampler (18.97 and 6.14 cm(3)), the position of sensor inside the sampler (in front and offset of 1.2 cm above the membrane) and the width of the diffusion slot (1.4 and 5.9 mm). The influences of these three parameters (internal volume, position of sensor inside the sampler, and width of the diffusion slot) were assessed and discussed with regard to the formaldehyde sampling rate and water uptake by sensor (potential interference of measure). Numerical simulations based on Fick's laws are in agreement with the experimental results and provide to estimate the effective diffusion coefficient of formaldehyde through the membrane (3.50 × 10(-6) m(2) s(-1)). Conversion factors between the sensor response, sampled formaldehyde mass and sampling rate were also assessed.

  20. On Chemical Modeling an Alchemical Process: The Use of Combined Chemical Methods in a Historical Study

    Science.gov (United States)

    Rodygin, Mikhail Yu.; Rodygin, Irene V.

    1997-08-01

    Laboratory work is an important component of a course in the History of Chemistry and Alchemy, though it can only be illustrative and not comprehensive. The course should exercise both the cognitive and research abilities of an university student. Therefore methods of modeling are of prime importance at this stage of instruction. Modeling can be both a priori and experimental. The experiment can use the alchemist's materials, or it can reproduce the procedure with modern reagents. A good example for the use of this method is a recipe for the preparation of the Philosopher's Stone attributed to Lullius and cited by J. Ripley in Liber Duodecium Portarum. Thus, the Ripley's recipe is not only considered to be the first indication of the existence of acetone, but it may also indicate the formation of acetyl acetone and its derivatives. Thus, as far as the history of alchemy is concerned, the use of an experimental model not only allows us to solve a number of specific problems such as recipe interpretation and product identification, but it allows also to probe the essence of alchemical work. The combination of empirical and speculative modelings leads to the interaction of the exact methods of chemistry with the broad historico-chemical generalizations, thus introducing some additional dimensions to the definition of historico-chemical practice.

  1. Highly Sensitive Hydrazine Chemical Sensor Based on CNT-PdPt Nanocomposites

    Directory of Open Access Journals (Sweden)

    Sung Phil Kim

    2015-01-01

    Full Text Available Bimetallic PdPt nanoparticles were prepared using the chemical reduction method. The PdPt nanoparticles were successfully deposited on thiolated carbon nanotubes (CNTs to form a CNT-PdPt nanocomposite as an electron mediator for the fabrication of a hydrazine sensor. The PdPt nanoparticles had an average particle size of 2.3 nm and were well dispersed on the surfaces of the CNTs in the prepared CNT-PdPt nanocomposite, as demonstrated using transmission electron microscopy (TEM, energy dispersive X-ray spectroscopy (EDX, and X-ray diffraction (XRD. Based on X-ray photoelectron spectroscopy (XPS results, the estimated proportions of Pd and Pt in the CNT-PdPt nanocomposite were approximately 3.0% and 3.2%, respectively. A fabricated chemical sensor based on CNT-PdPt was found to exhibit better amperometric activity with respect to the hydrazine oxidation reaction than CNT-Pd, CNT-Pt, and commercial Pd/C and Pt/C catalysts. This sensor exhibited a linear range of 0.55–1,200 μM and a detection limit of 0.28 μM (S/N = 3 with a fast response time (within 5 s. Furthermore, the sensor could be used repeatedly for the consecutive detection of hydrazine with good reusability and storage stability. These properties demonstrate that the CNT-PdPt nanocomposite is a promising electron mediator for the fabrication of amperometric hydrazine sensors.

  2. Fluorescence anion sensors based on combination of conformational restriction and photo-induced electron transfer

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ge, E-mail: liu_ge2008@163.com [Department of Chemistry, Chifeng University, Chifeng, 024000 (China); Shao, Jie, E-mail: njshao@live.cn [College of Chemistry, Chemical Engineering and Material Science, Soochow University, Suzhou, Jiangsu 215123 (China)

    2013-03-15

    Six fluorescence and colorimetric sensors (1-6) were designed and synthesized through a facile method. These compounds, whose structures were characterized by {sup 1}H NMR, elemental analyses and MS, could be easily prepared by simple synthesis method. In these sensor molecules, azo group and conjugated di-benzene unit acted as a chromophore and a fluorophore; respectively, and phenol moieties are anion binding sites. In dry DMSO solution, significant red shifts in UV-vis spectra with visible color changes were observed when the sensors were exposed to anions with strong base. Particularly, the simple compounds gave interesting fluorescence changes upon presence of anions, which probably resulted from electronic effects of the substituent. The sensors (1-3) with the nitro group exhibited 'turn-on' fluorescence responses to anions due to conformational restriction and 4-6 with absence of -NO{sub 2} group showed 'turn-off' fluorescence responses to anion owing to photo-induced electron transfer. - Highlights: Black-Right-Pointing-Pointer Six fluorescence and colorimetric anion sensors based on azo derivatives were showed. Black-Right-Pointing-Pointer Azo group and di-benzene unit acted as a chromophore and a fluorophore respectively. Black-Right-Pointing-Pointer Combination of conformational restriction and PET was exploited as fluorescence mechanism.

  3. Combining physiological, environmental and locational sensors for citizen-oriented health applications.

    Science.gov (United States)

    Huck, J J; Whyatt, J D; Coulton, P; Davison, B; Gradinar, A

    2017-03-01

    This work investigates the potential of combining the outputs of multiple low-cost sensor technologies for the direct measurement of spatio-temporal variations in phenomena that exist at the interface between our bodies and the environment. The example used herein is the measurement of personal exposure to traffic pollution, which may be considered as a function of the concentration of pollutants in the air and the frequency and volume of that air which enters our lungs. The sensor-based approach described in this paper removes the 'traditional' requirements either to model or interpolate pollution levels or to make assumptions about the physiology of an individual. Rather, a wholly empirical analysis into pollution exposure is possible, based upon high-resolution spatio-temporal data drawn from sensors for NO2, nasal airflow and location (GPS). Data are collected via a custom smartphone application and mapped to give an unprecedented insight into exposure to traffic pollution at the individual level. Whilst the quality of data from low-cost miniaturised sensors is not suitable for all applications, there certainly are many applications for which these data would be well suited, particularly those in the field of citizen science. This paper demonstrates both the potential and limitations of sensor-based approaches and discusses the wider relevance of these technologies for the advancement of citizen science.

  4. Detection of trace elements in DI water and comparison of several water solutions by using EF-FLRD chemical sensors

    Science.gov (United States)

    Kaya, M.; Wang, C.

    2017-02-01

    Detection of trace elements in DI water and comparison of several types of water respons such as DI water, tap water, and ocean water were studied by using EF-FLRD chemical sensors. Solutions of Mg, Fe, P, and Cd elements with a concentration of 1000 µg/ml (1 mg/ml) which corresponds to 1000 ppm by weight were tested. DI water, tap water, and real ocean water were utilized as medium to observe refractive index difference of solutions. The EF sensing technique which is based on the EF scattering effect was employed for the detection of trace chemicals and recording of solution responses. Due to the refractive index differences between solutions, optical loss of the sensor was different when the sensor head was immersed into solutions of approximately 10 ml each. The differences of the refractive indices are presented by recording ringdown times when the sensor head was immersed into the solutions. Fast response (˜1s), high sensitive, and reproducible EF-FLRD chemical sensors were fabricated and tested in laboratory conditions. High sensitivity of the sensors due to being capability of detecting smaller differences between measurands without any additional components or treatment makes the EF-FLRD sensors more attractive. Enhanced sensitivity of the EF-FLRD chemical sensors as a result of the multi-pass nature of the FLRD technique has potential application in detecting of trace elements in monitoring of water quality.

  5. Migrating the Mach-Zehnder chemical and bio-sensor to the mid-infrared region

    Science.gov (United States)

    Leidner, L.; Ewald, M.; Sieger, M.; Mizaikoff, B.; Gauglitz, G.

    2013-05-01

    The properties of integrated optical phase-modulated Mach-Zehnder interferometers (IO-MZI) are used to set up a new generation of chemical and biochemical sensors working in the mid-infrared. First applications of the MZI principle were introduced in the beginning 1990s. They range from a gas sensor to monitor organic solvent concentrations1 to setting up an immunoassay for the detection of the herbicide simazine2. Most if not all sensors of MZI type operate at wavelengths of the visible or near infrared spectrum. There are several reasons to change this strategy and move into the mid-infrared spectral range (MIR): higher manufacturing tolerances, increased evanescent field penetration depth, signal amplification by surface enhanced infrared absorption effect (SEIRA), species identification by MIR fingerprints. The basis of the planned MIR-MZI is a GaAs waveguide pattern epitaxially grown on a substrate3. As a first step towards nanostructuring the waveguide surface, chemical deposition of Au nanoparticles on GaAs transducers was established. For the use of MIR-MZI sensors in bioanalytical assay development, chemical immobilization of molecular recognition elements on GaAs transducers was carried out. The modified surfaces were characterized by atomic force microscopy (AFM), dark field microscopy, contact angle measurements and ellipsometric data as well as by a modified version of Reflectometric Interference Spectroscopy (RIfS)4. It was possible to monitor both the immobilization of gold nanoparticles and time-resolved specific binding using a model antibody antigen assay. After successful setup of relevant assays with RIfS, e.g. the detection of bacteria or endocrine disruptors, the assays are designed to be transferred onto the mid-infrared Mach-Zehnder interferometer.

  6. A Low-Noise DC Seismic Accelerometer Based on a Combination of MET/MEMS Sensors

    Directory of Open Access Journals (Sweden)

    Alexander Neeshpapa

    2014-12-01

    Full Text Available Molecular-electronic transducers (MET have a high conversion coefficient and low power consumption, and do not require precision mechanical components thus allowing the construction of cost- and power-efficient seismic accelerometers. Whereas the instrumental resolution of a MET accelerometer within the 0.1–100 Hz frequency range surpasses that of the best Micro-Electro Mechanical Systems (MEMS and even some force-balanced accelerometers, the fundamental inability to register gravity or, in other words, zero frequency acceleration, significantly constrains the further spread of MET-based accelerometers. Ways of obviating this inherent zero frequency insensitivity within MET technology have so far, not been found. This article explores a possible approach to the construction of a hybrid seismic accelerometer combining the superb performance of a MET sensor in the middle and high frequency range with a conventional on chip MEMS accelerometer covering the lower frequencies and gravity. Though the frequency separation of a signal is widely used in various applications, the opposite task, i.e., the combining of two signals with different bandwidths is less common. Based on theoretical research and the analysis of actual sensors’ performance, the authors determined optimal parameters for building a hybrid sensor. Description and results for implementation of the hybrid sensor are given in the Experimental section of the article. Completing a MET sensor with a cost-effective MEMS permitted the construction of a low noise DC accelerometer preserving the noise performance of a MET sensing element. The work presented herein may prove useful in designing other combined sensors based on different technologies.

  7. Paper-based capacitive sensors for identification and quantification of chemicals at the point of care.

    Science.gov (United States)

    Hu, Jie; Yew, Chee-Hong Takahiro; Chen, Xiaoshuang; Feng, Shangsheng; Yang, Qu; Wang, Shuqi; Wee, Wei-Hong; Pingguan-Murphy, Belinda; Lu, Tian Jian; Xu, Feng

    2017-04-01

    The identification and quantification of chemicals play a vital role in evaluation and surveillance of environmental health and safety. However, current techniques usually depend on costly equipment, professional staff, and/or essential infrastructure, limiting their accessibility. In this work, we develop paper-based capacitive sensors (PCSs) that allow simple, rapid identification and quantification of various chemicals from microliter size samples with the aid of a handheld multimeter. PCSs are low-cost parallel-plate capacitors (~$0.01 per sensor) assembled from layers of aluminum foil and filter paper via double-sided tape. The developed PCSs can identify different kinds of fluids (e.g., organic chemicals) and quantify diverse concentrations of substances (e.g., heavy metal ions) based on differences in dielectric properties, including capacitance, frequency spectrum, and dielectric loss tangent. The PCS-based method enables chemical identification and quantification to take place much cheaply, simply, and quickly at the point-of-care (POC), holding great promise for environmental monitoring in resource-limited settings.

  8. A pilot project combining multispectral proximal sensors and digital cameras for monitoring tropical pastures

    Science.gov (United States)

    Handcock, Rebecca N.; Gobbett, D. L.; González, Luciano A.; Bishop-Hurley, Greg J.; McGavin, Sharon L.

    2016-08-01

    Timely and accurate monitoring of pasture biomass and ground cover is necessary in livestock production systems to ensure productive and sustainable management. Interest in the use of proximal sensors for monitoring pasture status in grazing systems has increased, since data can be returned in near real time. Proximal sensors have the potential for deployment on large properties where remote sensing may not be suitable due to issues such as spatial scale or cloud cover. There are unresolved challenges in gathering reliable sensor data and in calibrating raw sensor data to values such as pasture biomass or vegetation ground cover, which allow meaningful interpretation of sensor data by livestock producers. Our goal was to assess whether a combination of proximal sensors could be reliably deployed to monitor tropical pasture status in an operational beef production system, as a precursor to designing a full sensor deployment. We use this pilot project to (1) illustrate practical issues around sensor deployment, (2) develop the methods necessary for the quality control of the sensor data, and (3) assess the strength of the relationships between vegetation indices derived from the proximal sensors and field observations across the wet and dry seasons. Proximal sensors were deployed at two sites in a tropical pasture on a beef production property near Townsville, Australia. Each site was monitored by a Skye SKR-four-band multispectral sensor (every 1 min), a digital camera (every 30 min), and a soil moisture sensor (every 1 min), each of which were operated over 18 months. Raw data from each sensor was processed to calculate multispectral vegetation indices. The data capture from the digital cameras was more reliable than the multispectral sensors, which had up to 67 % of data discarded after data cleaning and quality control for technical issues related to the sensor design, as well as environmental issues such as water incursion and insect infestations. We recommend

  9. Guided shear horizontal surface acoustic wave sensors for chemical and biochemical detection in liquids.

    Science.gov (United States)

    Josse, F; Bender, F; Cernose, R W

    2001-12-15

    The design and performance of guided shear horizontal surface acoustic wave (guided SH-SAW) devices on LiTaO3 substrates are investigated for high-sensitivity chemical and biochemical sensors in liquids. Despite their structural similarity to Rayleigh SAW, SH-SAWs often propagate slightly deeper within the substrate, hence preventing the implementation of high-sensitivity detectors. The device sensitivity to mass and viscoelastic loading is increased using a thin guiding layer on the device surface. Because of their relatively low shear wave velocity, various polymers including poly(methyl methacrylate) (PMMA) and cyanoethyl cellulose (cured or cross-linked) are investigated as the guiding layers to trap the acoustic energy near the sensing surface. The devices have been tested in biosensing and chemical sensing experiments. Suitable design principles for these applications are discussed with regard to wave guidance, electrical passivation of the interdigital transducers from the liquid environments, acoustic loss, and sensor signal distortion. In biosensing experiments, using near-optimal PMMA thickness of approximately 2 microm, mass sensitivity greater than 1500 Hz/(ng/mm2) is demonstrated, resulting in a minimum detection limit less than 20 pg/mm2. For chemical sensor experiments, it is found that optimal waveguide thickness must be modified to account for the chemically sensitive layer which also acts to guide the SH-SAW. A detection limit of 780 (3 x peak-to-peak noise) or 180 ppb (3 x rms noise) is estimated from the present measurements for some organic compounds in water.

  10. Chemically robust platform for optical solid-state conducting polymer sensor

    Science.gov (United States)

    Holt, A. L.; Bearinger, J. P.; Carter, S. A.

    2006-10-01

    Conjugated polymers are unique materials for use in the development of chemical and biological sensors because of their widely tunable optical and electrical properties that allow them dual functionality as both the sensing element and the signal transducer. Furthermore, as optical photoluminescence based sensors, electroactive polymers are found to exhibit high sensitivity due to the ability of the analyte of interest to quench the photoluminescence of the entire polymer chain. In order to produce a more chemically robust thin film for use as a "solid-state" optical sensor, we succeeded in grafting various poly (3-alkyl-thiophene)s to optically transparent substrates such as glass, quartz, and ITO coated glass. This was accomplished by first grafting a thiophene monomer to the surface then chemically growing the films via oxidative polymerization. XPS studies indicated that each chemical step was accurately understood. The polythiophene growth, unaltered by sonication and tape peeling tests, was uniform across the substrate and could be directed by selective silanization of the substrate. Film thicknesses range from 20 to 200 nm and exhibit varying degrees of surface roughness, depending on the polymerization process. The reaction times and solvents were varied in order to optimize the desired film properties. The absorption and photoluminescence properties of the thin films compared well with literature on spun-cast polythiophene films, as did the electrical conductivities of the doped and undoped material. The photoluminescence intensities of the films are found to be unaffected by paraquat in water but are sensitive to trace amounts of ferric chloride in acetonitrile with measurable Stern Volmer constants.

  11. Chemical Discrimination in Turbulent Gas Mixtures with MOX Sensors Validated by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Jordi Fonollosa

    2014-10-01

    Full Text Available Chemical detection systems based on chemo-resistive sensors usually include a gas chamber to control the sample air flow and to minimize turbulence. However, such a kind of experimental setup does not reproduce the gas concentration fluctuations observed in natural environments and destroys the spatio-temporal information contained in gas plumes. Aiming at reproducing more realistic environments, we utilize a wind tunnel with two independent gas sources that get naturally mixed along a turbulent flow. For the first time, chemo-resistive gas sensors are exposed to dynamic gas mixtures generated with several concentration levels at the sources. Moreover, the ground truth of gas concentrations at the sensor location was estimated by means of gas chromatography-mass spectrometry. We used a support vector machine as a tool to show that chemo-resistive transduction can be utilized to reliably identify chemical components in dynamic turbulent mixtures, as long as sufficient gas concentration coverage is used. We show that in open sampling systems, training the classifiers only on high concentrations of gases produces less effective classification and that it is important to calibrate the classification method with data at low gas concentrations to achieve optimal performance.

  12. Chemical discrimination in turbulent gas mixtures with MOX sensors validated by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Fonollosa, Jordi; Rodríguez-Luján, Irene; Trincavelli, Marco; Vergara, Alexander; Huerta, Ramón

    2014-10-16

    Chemical detection systems based on chemo-resistive sensors usually include a gas chamber to control the sample air flow and to minimize turbulence. However, such a kind of experimental setup does not reproduce the gas concentration fluctuations observed in natural environments and destroys the spatio-temporal information contained in gas plumes. Aiming at reproducing more realistic environments, we utilize a wind tunnel with two independent gas sources that get naturally mixed along a turbulent flow. For the first time, chemo-resistive gas sensors are exposed to dynamic gas mixtures generated with several concentration levels at the sources. Moreover, the ground truth of gas concentrations at the sensor location was estimated by means of gas chromatography-mass spectrometry. We used a support vector machine as a tool to show that chemo-resistive transduction can be utilized to reliably identify chemical components in dynamic turbulent mixtures, as long as sufficient gas concentration coverage is used. We show that in open sampling systems, training the classifiers only on high concentrations of gases produces less effective classification and that it is important to calibrate the classification method with data at low gas concentrations to achieve optimal performance.

  13. Nano-photonic chemical sensor using rare-earth upconversion phosphors

    Science.gov (United States)

    Patel, Darayas N.; Blockmon, Avery; Ochieng, Vanesa; Sarkisov, Sergey S.; Darwish, Abdalla M.; Sarkisov, Avedik S.

    2017-02-01

    The objective of the paper was to demonstrate feasibility of a chemical (ammonia) sensor using dye-doped polymer nanocomposite with upconversion phosphor nano-particles. The micro-crystalline powder of upconversion rare-earth phosphor NaYF4:Yb3+, Er3+ was synthesized using a simple wet process followed up by baking in open air. The powder was reduced into nano-colloid with 100-nm nano-particles using the ball milling process. The nano-colloid was added to the solution of polymer poly(methyl methacrylate) known as PMMA. Additionally, a pH indicator dye (Phenol Red or Bromothymol Blue) was dissolved in polymer solution. The dye-doped polymer nanocomposite films were deposited on substrates using the dipping process followed by baking in order to evaporate the solvent. The deposited nano-photonic sensor film had bright green upconversion fluorescence with a spectral peak at 540 nm attributed to the nano-photonic rare-earth phosphor pumped with a 980 nm infrared diode laser. The spectrum of green emission matched the absorption band of the indicator dye exposed to ammonia. When the film was exposed to ammonia, it demonstrated an optical response in the form of the drop of intensity of green radiation measured with a silicon photodiode power meter. The sensitivity of the developed chemical sensor was close to 0.4% ammonia in air, and the response time was close to 5 minutes.

  14. Review of sensors for the in situ chemical characterization of the Hanford underground storage tanks

    Energy Technology Data Exchange (ETDEWEB)

    Kyle, K.R.; Mayes, E.L.

    1994-07-29

    Lawrence Livermore National Laboratory (LLNL), in the Technical Task Plan (TTP) SF-2112-03 subtask 2, is responsible for the conceptual design of a Raman probe for inclusion in the in-tank cone penetrometer. As part of this task, LLNL is assigned the further responsibility of generating a report describing a review of sensor technologies other than Raman that can be incorporated in the in-tank cone penetrometer for the chemical analysis of the tank environment. These sensors would complement the capabilities of the Raman probe, and would give information on gaseous, liquid, and solid state species that are insensitive to Raman interrogation. This work is part of a joint effort involving several DOE laboratories for the design and development of in-tank cone penetrometer deployable systems for direct UST waste characterization at Westinghouse Hanford Company (WHC) under the auspices of the U.S. Department of Energy (DOE) Underground Storage Tank Integrated Demonstration (UST-ID).

  15. Oil degradation monitoring with chemical sensors and molecular imprinted polymer; Monitorizacion de la degradacion de aceites con sensores quimicos y polimeros de impronta molecular

    Energy Technology Data Exchange (ETDEWEB)

    Calvo, J.L.; Meizoso, M.C.; Gonzalez Rodriguez, M.V.; Lopez Vilarino, J.M.; Cela, M.C.

    2010-07-01

    The engine operation state can be reported by real-time monitoring programs. Detecting early signs of equipment failure is the aim of these maintenance programs.Chemical sensors are devices that can perform this function in predictive maintenance.The monitoring of the degradation of automotive engine oils has been achieved by chemical sensors coated with synthetic recognition elements. Following, the elements that make up the QCM device, MIPs, organic-inorganic hybrid materials obtained by sol-gel and electronic packaging are described. (Author).

  16. Two-Dimensional Atomic-Layered Alloy Junctions for High-Performance Wearable Chemical Sensor.

    Science.gov (United States)

    Cho, Byungjin; Kim, Ah Ra; Kim, Dong Jae; Chung, Hee-Suk; Choi, Sun Young; Kwon, Jung-Dae; Park, Sang Won; Kim, Yonghun; Lee, Byoung Hun; Lee, Kyu Hwan; Kim, Dong-Ho; Nam, Jaewook; Hahm, Myung Gwan

    2016-08-03

    We first report that two-dimensional (2D) metal (NbSe2)-semiconductor (WSe2)-based flexible, wearable, and launderable gas sensors can be prepared through simple one-step chemical vapor deposition of prepatterned WO3 and Nb2O5. Compared to a control device with a Au/WSe2 junction, gas-sensing performance of the 2D NbSe2/WSe2 device was significantly enhanced, which might have resulted from the formation of a NbxW1-xSe2 transition alloy junction lowering the Schottky barrier height. This would make it easier to collect charges of channels induced by molecule adsorption, improving gas response characteristics toward chemical species including NO2 and NH3. 2D NbSe2/WSe2 devices on a flexible substrate provide gas-sensing properties with excellent durability under harsh bending. Furthermore, the device stitched on a T-shirt still performed well even after conventional cleaning with a laundry machine, enabling wearable and launderable chemical sensors. These results could pave a road toward futuristic gas-sensing platforms based on only 2D materials.

  17. Chemical Sensors Based on IR Spectroscopy and Surface-Modified Waveguides

    Science.gov (United States)

    Lopez, Gabriel P.; Niemczyk, Thomas

    1999-01-01

    Sol-gel processing techniques have been used to apply thin porous films to the surfaces of planar infrared (IR) waveguides to produce widely useful chemical sensors. The thin- film coating serves to diminish the concentration of water and increase the concentration of the analyte in the region probed by the evanescent IR wave. These porous films are composed of silica, and therefore, conventional silica surface modification techniques can be used to give the surface a specific functional character. The sol-gel film was surface-modified to make the film highly hydrophobic. These sensors were shown to be capable of detecting non-polar organic analytes, such as benzonitrile, in aqueous solution with detection limits in the ppb range. Further, these porous sol-gel structures allow the analytes to diffuse into and out of the films rapidly, thus reaching equilibrium in less than ten seconds. These sensors are unique because of the fact that their operation is based on the measurement of an IR absorption spectrum. Thus, these sensors are able to identify the analytes as well as measure concentration with high sensitivity. These developments have been documented in previous reports and publications. Recently, we have also targeted detection of the polar organic molecules acetone and isopropanol in aqueous solution. Polar organics are widely used in industrial and chemical processes, hence it is of interest to monitor their presence in effluents or decontamination process flows. Although large improvements in detection limits were expected with non-polar organic molecules in aqueous solutions using very hydrophobic porous sol-gel films on silicon attenuated total reflectance (Si ATR) waveguides, it was not as clear what the detection enhancements might be for polar organic molecules. This report describes the use of modified sol-gel-coated Si ATR sensors for trace detection and quantitation of small polar organic molecules in aqueous solutions. The detection of both acetone

  18. Chip implementation with a combined wireless temperature sensor and reference devices based on the DZTC principle.

    Science.gov (United States)

    Chang, Ming-Hui; Huang, Yu-Jie; Huang, Han-Pang; Lu, Shey-Shi

    2011-01-01

    This paper presents a novel CMOS wireless temperature sensor design in order to improve the sensitivity and linearity of our previous work on such devices. Based on the principle of CMOS double zero temperature coefficient (DZTC) points, a combined device is first created at the chip level with two voltage references, one current reference, and one temperature sensor. It was successfully fabricated using the 0.35 μm CMOS process. According to the chip results in a wide temperature range from -20 °C to 120 °C, two voltage references can provide temperature-stable outputs of 823 mV and 1,265 mV with maximum deviations of 0.2 mV and 8.9 mV, respectively. The result for the current reference gives a measurement of 23.5 μA, with a maximum deviation of 1.2 μA. The measurements also show that the wireless temperature sensor has good sensitivity of 9.55 mV/°C and high linearity of 97%. The proposed temperature sensor has 4.15-times better sensitivity than the previous design. Moreover, to facilitate temperature data collection, standard wireless data transmission is chosen; therefore, an 8-bit successive-approximation-register (SAR) analog-to-digital converter (ADC) and a 433 MHz wireless transmitter are also integrated in this chip. Sensing data from different places can be collected remotely avoiding the need for complex wire lines.

  19. Image-Based Airborne Sensors: A Combined Approach for Spectral Signatures Classification through Deterministic Simulated Annealing

    Science.gov (United States)

    Guijarro, María; Pajares, Gonzalo; Herrera, P. Javier

    2009-01-01

    The increasing technology of high-resolution image airborne sensors, including those on board Unmanned Aerial Vehicles, demands automatic solutions for processing, either on-line or off-line, the huge amountds of image data sensed during the flights. The classification of natural spectral signatures in images is one potential application. The actual tendency in classification is oriented towards the combination of simple classifiers. In this paper we propose a combined strategy based on the Deterministic Simulated Annealing (DSA) framework. The simple classifiers used are the well tested supervised parametric Bayesian estimator and the Fuzzy Clustering. The DSA is an optimization approach, which minimizes an energy function. The main contribution of DSA is its ability to avoid local minima during the optimization process thanks to the annealing scheme. It outperforms simple classifiers used for the combination and some combined strategies, including a scheme based on the fuzzy cognitive maps and an optimization approach based on the Hopfield neural network paradigm. PMID:22399989

  20. Image-Based Airborne Sensors: A Combined Approach for Spectral Signatures Classification through Deterministic Simulated Annealing.

    Science.gov (United States)

    Guijarro, María; Pajares, Gonzalo; Herrera, P Javier

    2009-01-01

    The increasing technology of high-resolution image airborne sensors, including those on board Unmanned Aerial Vehicles, demands automatic solutions for processing, either on-line or off-line, the huge amountds of image data sensed during the flights. The classification of natural spectral signatures in images is one potential application. The actual tendency in classification is oriented towards the combination of simple classifiers. In this paper we propose a combined strategy based on the Deterministic Simulated Annealing (DSA) framework. The simple classifiers used are the well tested supervised parametric Bayesian estimator and the Fuzzy Clustering. The DSA is an optimization approach, which minimizes an energy function. The main contribution of DSA is its ability to avoid local minima during the optimization process thanks to the annealing scheme. It outperforms simple classifiers used for the combination and some combined strategies, including a scheme based on the fuzzy cognitive maps and an optimization approach based on the Hopfield neural network paradigm.

  1. Towards a new generation of fibre optic chemical sensors based on spider silk threads

    Science.gov (United States)

    Hey Tow, Kenny; Chow, Desmond M.; Vollrath, Fritz; Dicaire, Isabelle; Gheysens, Tom; Thévenaz, Luc

    2017-04-01

    A spider uses up to seven different types of silk, all having specific functions, to build its web. For scientists, native silk - directly extracted from spiders - is a tough, biodegradable and biocompatible thread used mainly for tissue engineering and textile applications. Blessed with outstanding optical properties, this protein strand can also be used as an optical fibre and is, moreover, intrinsically sensitive to chemical compounds. In this communication, a pioneering proof-of-concept experiment using spider silk, in its pristine condition, as a new type of fibre-optic relative humidity sensor will be demonstrated and its potential for future applications discussed.

  2. Colorimetric Sensor Arrays for the Detection and Identification of Chemical Weapons and Explosives.

    Science.gov (United States)

    Kangas, Michael J; Burks, Raychelle M; Atwater, Jordyn; Lukowicz, Rachel M; Williams, Pat; Holmes, Andrea E

    2017-03-04

    There is a significant demand for devices that can rapidly detect chemical-biological-explosive (CBE) threats on-site and allow for immediate responders to mitigate spread, risk, and loss. The key to an effective reconnaissance mission is a unified detection technology that analyzes potential threats in real time. In addition to reviewing the current state of the art in the field, this review illustrates the practicality of colorimetric arrays composed of sensors that change colors in the presence of analytes. This review also describes an outlook toward future technologies, and describes how they could possibly be used in areas such as war zones to detect and identify hazardous substances.

  3. Electrocatalytic Organic-Inorganic Hybrid Films and Their Applications in Chemical Sensors and Biosensors

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    @@ In this report, we will present the organic-inorganic hybrid molecular films prepared in our group and their applications in chemical sensors and biosensors.Many types of multi-layered films have been prepared in an alternatively assembled organic-inorganic and layer-by-layer manner. We will focus on the alternatively organized organic surfactant and metal-complex films and their conversion into electrocatalytically active films. Especially, we will demonstrate the preparation of bifunctional films for the detection of two different but correlated species, such as nitric oxide and oxygen, in biomedia.

  4. Electrocatalytic Organic-Inorganic Hybrid Films and Their Applications in Chemical Sensors and Biosensors

    Institute of Scientific and Technical Information of China (English)

    LI; XiaoYuan

    2001-01-01

    In this report, we will present the organic-inorganic hybrid molecular films prepared in our group and their applications in chemical sensors and biosensors.Many types of multi-layered films have been prepared in an alternatively assembled organic-inorganic and layer-by-layer manner. We will focus on the alternatively organized organic surfactant and metal-complex films and their conversion into electrocatalytically active films. Especially, we will demonstrate the preparation of bifunctional films for the detection of two different but correlated species, such as nitric oxide and oxygen, in biomedia.  ……

  5. Sensors

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, H. [PBI-Dansensor A/S (Denmark); Toft Soerensen, O. [Risoe National Lab., Materials Research Dept. (Denmark)

    1999-10-01

    A new type of ceramic oxygen sensors based on semiconducting oxides was developed in this project. The advantage of these sensors compared to standard ZrO{sub 2} sensors is that they do not require a reference gas and that they can be produced in small sizes. The sensor design and the techniques developed for production of these sensors are judged suitable by the participating industry for a niche production of a new generation of oxygen sensors. Materials research on new oxygen ion conducting conductors both for applications in oxygen sensors and in fuel was also performed in this project and finally a new process was developed for fabrication of ceramic tubes by dip-coating. (EHS)

  6. Sensors

    CERN Document Server

    Pigorsch, Enrico

    1997-01-01

    This is the 5th edition of the Metra Martech Directory "EUROPEAN CENTRES OF EXPERTISE - SENSORS." The entries represent a survey of European sensors development. The new edition contains 425 detailed profiles of companies and research institutions in 22 countries. This is reflected in the diversity of sensors development programmes described, from sensors for physical parameters to biosensors and intelligent sensor systems. We do not claim that all European organisations developing sensors are included, but this is a good cross section from an invited list of participants. If you see gaps or omissions, or would like your organisation to be included, please send details. The data base invites the formation of effective joint ventures by identifying and providing access to specific areas in which organisations offer collaboration. This issue is recognised to be of great importance and most entrants include details of collaboration offered and sought. We hope the directory on Sensors will help you to find the ri...

  7. Development of Zr/ZrO2 high temperature and high pressure sensors for in-situ measuring chemical parameters of deep-sea water

    Institute of Scientific and Technical Information of China (English)

    ZHANG XueTong; ZHANG RongHua; HU ShuMin; WANG Yong

    2009-01-01

    In order to in situ measure chemical parameters of deep-sea water and hydrothermal fluids at midocean ridge(MOR),it is necessary to use high temperature and high pressure chemical sensors.Developing new sensors is essential to measure in-situ pH and other chemical parameters(dissolved H2,dissolved H2S)of deep-sea water and hydrothermal fluids in a wide temperature range(2℃-400℃)at MOR vents.The YSZ(Yttria Stabilized Zirconia,9%Y2O3)ceramic-based(HgO/Hg)chemical sensors possess excellent electrochemical properties at high temperatures,which have been used to measure chemical parameters of hydrothermsl fluids above 200℃.A novel Zr/ZrO2 oxidation/reduction electrode was constructed by oxidation of Zr wire in Na2CO3 melt.This Zr/ZrO2 electrode has good chemical stability while measuring pH of high-temperature aqueous solutions,combined with a Ag/AgCl reference electrode.Potentials of the Zr/ZrO2 sensor in association with a Ag/AgCl reference electrode vary linearly with pH over a wide pH range,as tested by various NaCI-HCI-H2O solutions(NaOH-NaCI-H2O for basic solutions),at temperatures in the range of 20℃-200℃.Thus,the Zr/ZrO2 sensors can be utilized in monitoring the fluids over the temperature range of 2℃-200℃.The Zr/ZrO2 electrode combined with Ag/AgCI,Ag/Ag2S,and Au electrodes has been used to measure pH and other chemical parameters (dissolved H2,dissolved H2S)of aqueous fluids from low to high temperatures and high pressures in the laboratory and to monitor those parameters of deep-sea water in South China Sea.

  8. Development of Zr/ZrO2 high temperature and high pressure sensors for in-situ measuring chemical parameters of deep-sea water

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    In order to in situ measure chemical parameters of deep-sea water and hydrothermal fluids at midocean ridge(MOR), it is necessary to use high temperature and high pressure chemical sensors.Developing new sensors is essential to measure in-situ pH and other chemical parameters(dissolved H2, dissolved H2S) of deep-sea water and hydrothermal fluids in a wide temperature range(2℃―400℃) at MOR vents.The YSZ(Yttria Stabilized Zirconia, 9%Y2O3) ceramic-based(HgO/Hg) chemical sensors possess excellent electrochemical properties at high temperatures, which have been used to measure chemical parameters of hydrothermal fluids above 200℃.A novel Zr/ZrO2 oxidation/reduction electrode was constructed by oxidation of Zr wire in Na2CO3 melt.This Zr/ZrO2 electrode has good chemical stability while measuring pH of high-temperature aqueous solutions, combined with a Ag/AgCl reference electrode.Potentials of the Zr/ZrO2 sensor in association with a Ag/AgCl reference electrode vary linearly with pH over a wide pH range, as tested by various NaCl-HCl-H2O solutions(NaOH-NaCl-H2O for basic solutions), at temperatures in the range of 20℃―200℃.Thus, the Zr/ZrO2 sensors can be utilized in monitoring the fluids over the temperature range of 2℃―200℃.The Zr/ZrO2 electrode combined with Ag/AgCl, Ag/Ag2S, and Au electrodes has been used to measure pH and other chemical parameters(dissolved H2, dissolved H2S) of aqueous fluids from low to high temperatures and high pressures in the laboratory and to monitor those parameters of deep-sea water in South China Sea.

  9. Core Analysis Combining MT (TIPPER) and Dielectric Sensors (Sans EC) in Earth and Space

    Science.gov (United States)

    Mound, Michael C.; Dudley, Kenneth L.

    2015-01-01

    On terrestrial planets and moons of our solar system cores reveal details about a geological structure's formation, content, and history. The strategy for the search for life is focused first on finding water which serves as a universal solvent, and identifying the rocks which such solvent act upon to release the constituent salts, minerals, ferrites, and organic compounds and chemicals necessary for life. Dielectric spectroscopy measures the dielectric properties of a medium as a function of frequency. Reflection measurements in the frequency range from 300 kHz to 300 MHz were carried out using RF and microwave network analyzers interrogating SansEC Sensors placed on clean geological core samples. These were conducted to prove the concept feasibility of a new geology instrument useful in the field and laboratory. The results show that unique complex frequency spectra can be acquired for a variety of rock core samples. Using a combination of dielectric spectroscopy and computer simulation techniques the magnitude and phase information of the frequency spectra can be converted to dielectric spectra. These low-frequency dielectric properties of natural rock are unique, easily determined, and useful in characterizing geology. TIPPER is an Electro-Magnetic Passive-Source Geophysical Method for Detecting and Mapping Geothermal Reservoirs and Mineral Resources. This geophysical method uses distant lightning and solar wind activity as its energy source. The most interesting deflections are caused by the funneling of electrons into more electrically conductive areas like mineralized faults, water or geothermal reservoirs. We propose TIPPER to be used with SansEC for determining terrain/ocean chemistry, ocean depth, geomorphology of fracture structures, and other subsurface topography characteristics below the ice crust of Jovian moons. NASA envisions lander concepts for exploration of these extraterrestrial icy surfaces and the oceans beneath. One such concept would use a

  10. Feasibility study of the microforming combined with selective chemical vapor deposition

    Directory of Open Access Journals (Sweden)

    Koshimizu Kazushi

    2015-01-01

    Full Text Available Microforming has been received much attention in the recent decades due to the wide use of microparts in electronics and medical applications. For the further functionalization of these micro devices, high functional surfaces with noble metals and nanomaterials are strongly required in bio- and medical fields, such as bio-sensors. To realize an efficient manufacturing process, which can deform the submillimeter scale bulk structure and can construct the micro to nanometer scale structures in one process, the present study proposes a combined process of microforming for metal foils with a selective chemical vapor deposition (SCVD on the active surfaces of the working material. To demonstrate feasibility of this proposed process, feasibility of SCVD of functional materials onto active surfaces of titanium (Ti was investigated. CVD of iron (Fe and carbon nanotubes (CNTs which construct CNTs on the patterned surfaces of the active Ti and non-active Ti oxidation layers were conducted. Ti thin films on silicon substrate and Fe were used as working materials and functional materials respectively. CNTs were grown only on the Ti surface. Consequently, selectivity of the active surface of Ti to the synthesis of Fe particles in CVD was confirmed.

  11. Synthesis of copper telluride nanowires using template-based electrodeposition method as chemical sensor

    Indian Academy of Sciences (India)

    Sandeep Arya; Saleem Khan; Suresh Kumar; Rajnikant Verma; Parveen Lehana

    2013-08-01

    Copper telluride (CuTe) nanowires were synthesized electrochemically from aqueous acidic solution of copper (II) sulphate (CuSO4.5H2O) and tellurium oxide (TeO2) on a copper substrate by template-assisted electrodeposition method. The electrodeposition was conducted at 30 °C and the length of nanowires was controlled by adjusting deposition time. Structural characteristics were examined using X-ray diffraction and scanning electron microscope which confirm the formation of CuTe nanowires. Investigation for chemical sensing was carried out using air and chloroform, acetone, ethanol, glycerol, distilled water as liquids having dielectric constants 1, 4.81, 8.93, 21, 24.55, 42.5 and 80.1, respectively. The results unequivocally prove that copper telluride nanowires can be fabricated as chemical sensors with enhanced sensitivity and reliability.

  12. A combined sensor for simultaneous high resolution 2-D imaging of oxygen and trace metals fluxes

    DEFF Research Database (Denmark)

    Stahl, Henrik; Warnken, Kent W.; Sochaczewski, Lukasz

    2012-01-01

    A new sandwich sensor, consisting of an O-2 planar optode overlain by a thin (90 mu m) DGT layer is presented. This sensor can simultaneously resolve 2-D O-2 dynamics and trace metal fluxes in benthic substrates at a high spatial resolution. The DGT layer accumulates metals on a small particle size...... (0.2 mu m) chelating resin and records the locally induced trace metal flux during the deployment, whereas the planar optode resolves the O-2 dynamic in near real time at the same location in the sediment. Despite its ultrathin composition, the DGT layer has high carrying capacity for trace metals...... with no saturation problems during application to typical coastal-or contaminated sediments. Combined with laser ablation, accumulated metal fluxes could be resolved at a resolution of similar to 200 mu m, whereas the O-2 images had a resolution of similar to 100 mu m. A 2-D diffusion-reaction model showed...

  13. Evaluation of a novel chemical sensor system to detect clinical mastitis in bovine milk.

    Science.gov (United States)

    Mottram, Toby; Rudnitskaya, Alisa; Legin, Andrey; Fitzpatrick, Julie L; Eckersall, P David

    2007-05-15

    Automatic detection of clinical mastitis is an essential part of high performance and robotic milking. Currently available technology (conductivity monitoring) is unable to achieve acceptable specificity or sensitivity of detection of clinical mastitis or other clinical diseases. Arrays of sensors with high cross-sensitivity have been successfully applied for recognition and quantitative analysis of other multicomponent liquids. An experiment was conducted to determine whether a multisensor system ("electronic tongue") based on an array of chemical sensors and suitable data processing could be used to discriminate between milk secretions from infected and healthy glands. Measurements were made with a multisensor system of milk samples from two different farms in two experiments. A total of 67 samples of milk from both mastitic and healthy glands were in two sets. It was demonstrated that the multisensor system could distinguish between control and clinically mastitic milk samples (p=0.05). The sensitivity and specificity of the sensor system (93 and 96% correspondingly) showed an improvement over conductivity (56 and 82% correspondingly). The multisensor system offers a novel method of improving mastitis detection.

  14. An efficient approach for preprocessing data from a large-scale chemical sensor array.

    Science.gov (United States)

    Leo, Marco; Distante, Cosimo; Bernabei, Mara; Persaud, Krishna

    2014-09-24

    In this paper, an artificial olfactory system (Electronic Nose) that mimics the biological olfactory system is introduced. The device consists of a Large-Scale Chemical Sensor Array (16; 384 sensors, made of 24 different kinds of conducting polymer materials)that supplies data to software modules, which perform advanced data processing. In particular, the paper concentrates on the software components consisting, at first, of a crucial step that normalizes the heterogeneous sensor data and reduces their inherent noise. Cleaned data are then supplied as input to a data reduction procedure that extracts the most informative and discriminant directions in order to get an efficient representation in a lower dimensional space where it is possible to more easily find a robust mapping between the observed outputs and the characteristics of the odors in input to the device. Experimental qualitative proofs of the validity of the procedure are given by analyzing data acquired for two different pure analytes and their binary mixtures. Moreover, a classification task is performed in order to explore the possibility of automatically recognizing pure compounds and to predict binary mixture concentrations.

  15. Mass sensitivity analysis and designing of surface acoustic wave resonators for chemical sensors

    Science.gov (United States)

    Kshetrimayum, Roshan; Yadava, R. D. S.; Tandon, R. P.

    2009-05-01

    The sensitivity of surface acoustic wave (SAW) chemical sensors depends on several factors such as the frequency and phase point of SAW device operation, sensitivity of the SAW velocity to surface mass loading, sensitivity of the SAW oscillator resonance to the loop phase shift, film thickness and oscillator electronics. This paper analyzes the influence of the phase point of operation in SAW oscillator sensors based on two-port resonator devices. It is found that the mass sensitivity will be enhanced if the SAW device has a nonlinear dependence on the frequency (delay ~ frequency-1). This requires the device to generate and operate in a ωτg(ω) = const region in the device passband, where ω denotes the angular frequency of oscillation and τg(ω) denotes the phase slope of the SAW resonator device. A SAW coupled resonator filter (CRF) that take advantage of mode coupling is considered in realizing such a device to help in shaping the phase transfer characteristics of a high mass sensitivity sensor. The device design and simulation results are presented within the coupling-of-modes formalism.

  16. Combined pre-concentration and real-time in-situ chemical detection of explosives in the marine environment

    Science.gov (United States)

    Dock, Matthew L.; Harper, Ross J.; Knobbe, Ed

    2010-04-01

    ICx Nomadics has developed the first known real-time sensor system that is capable of detecting chemical signatures emanating from underwater explosives, based upon the same amplifying fluorescent polymer (AFP) fluorescence-quenching transduction mechanism that the Fido® family of explosives detectors utilizes. The SeaPup is capable of real-time detection of the trace chemical signatures emanating from submerged explosive compounds and has been successfully tested on various marine platforms, including a crawler robot, an autonomous underwater vehicle (AUV), and a remotely operated underwater vehicle (ROV). The present work is focused on advances in underwater in-situ chemical sensing; wherein trace amounts of dissolved explosive compounds may be detected and discriminated from other chemical species found in the marine environment. Recent progress with the SeaPup platform have focused on increasing the sensitivity of the AFP matrix through the development of a preconcentration system designed to harvest explosive analytes from a larger sample volume over a predetermined period of time. This permits real time monitoring of chemical plumes during the approach to a potential source, combined with the lowered limit of detection from extended sampling of targeted items. SeaPup has been shown to effectively map "explosive scent plumes" emanating from an underwater source of TNT, and the preconcentration system has previously been demonstrated to enhance sensitivity be over 2 orders of magnitude in a time window of minutes.

  17. Chalcogenide glass mid-infrared on-chip sensor for chemical sensing

    Science.gov (United States)

    Lin, Hongtao

    Chemical sensing in the mid-infrared (mid-IR) has been considered to be significant for molecular detection for decades, but until recently has mostly relied on benchtop spectroscopic instruments like Fourier transform infrared spectrometers, etc. Recent strides in planar photonic integration envision compact, standalone "sensor-on-a-chip" devices for molecular analysis as a potentially disruptive technology as compared to their conventional bulky counterparts. However, the difficulty of achieving adequate sensitivity in integrated optical sensors is still a key barrier towards their practical application, limited by the weak interactions between photons and molecules over the short optical path length accessible on a chip. To solve the sensitivity challenge, a novel mid-IR photothermal spectroscopic sensing technique was proposed and theoretically examined. Through dramatically amplified photothermal effects in an optical nano-cavity doubly resonant at both mid-IR pump and near infrared probe wavelengths, a device design based on nested 1-D nanobeam photonic crystal cavities is numerically analyzed to demonstrate the technique's potential for single small gas molecule detection without the need for cryogenically cooled mid-IR photo-detectors. Furthermore, since silica becomes opaque at wavelengths beyond 3.5 microm, new material platforms and fabrication techniques are needed for mid-IR on-chip chemical sensors. Chalcogenide glasses (ChG), amorphous compounds containing S, Se and Te, are ideal material choices for mid-IR chemical sensors given their broad mid-IR transparency window, large photothermal figure-of-merit, amorphous structure and low processing temperature. A ChG lift-off process and a nano-fabrication technique using focused ion beam milling have been developed to fabricate mid-IR ChG resonators and photonic crystal waveguide cavities. ChG resonators on CaF2 substrate claimed a high quality factor around 4 x 105. Using these devices, we have also

  18. Coupled sensor/platform control design for low-level chemical detection with position-adaptive micro-UAVs

    Science.gov (United States)

    Goodwin, Thomas; Carr, Ryan; Mitra, Atindra K.; Selmic, Rastko R.

    2009-05-01

    We discuss the development of Position-Adaptive Sensors [1] for purposes for detecting embedded chemical substances in challenging environments. This concept is a generalization of patented Position-Adaptive Radar Concepts developed at AFRL for challenging conditions such as urban environments. For purposes of investigating the detection of chemical substances using multiple MAV (Micro-UAV) platforms, we have designed and implemented an experimental testbed with sample structures such as wooden carts that contain controlled leakage points. Under this general concept, some of the members of a MAV swarm can serve as external position-adaptive "transmitters" by blowing air over the cart and some of the members of a MAV swarm can serve as external position-adaptive "receivers" that are equipped with chemical or biological (chem/bio) sensors that function as "electronic noses". The objective can be defined as improving the particle count of chem/bio concentrations that impinge on a MAV-based position-adaptive sensor that surrounds a chemical repository, such as a cart, via the development of intelligent position-adaptive control algorithms. The overall effect is to improve the detection and false-alarm statistics of the overall system. Within the major sections of this paper, we discuss a number of different aspects of developing our initial MAV-Based Sensor Testbed. This testbed includes blowers to simulate position-adaptive excitations and a MAV from Draganfly Innovations Inc. with stable design modifications to accommodate our chem/bio sensor boom design. We include details with respect to several critical phases of the development effort including development of the wireless sensor network and experimental apparatus, development of the stable sensor boom for the MAV, integration of chem/bio sensors and sensor node onto the MAV and boom, development of position-adaptive control algorithms and initial tests at IDCAST (Institute for the Development and

  19. Microfluidic platforms employing integrated fluorescent or luminescent chemical sensors: a review of methods, scope and applications

    Science.gov (United States)

    Pfeiffer, Simon A.; Nagl, Stefan

    2015-09-01

    Herein we critically review microfluidic platforms that contain integrated fluorescent or luminescent chemical sensor assemblies. These were employed in particular for miniaturized oxygen and pH sensing. Microchips with optical temperature sensing capability are also covered since these share many concepts and applications. Other analytes and derived parameters from the above analytes are found in some sensing approaches in microfluidics. After an introduction, the work is structured into three main chapters dealing with the fabrication and microintegration of these sensors, readout and detection strategies, and applications of these microsystems. The fabrication is discussed with a focus on soft lithography-based approaches in polydimethylsiloxane (PDMS) or PDMS and glass hybrid devices that form the majority of work so far. Alternative approaches, particularly using glass or quartz as the main chip material are also covered. Detection techniques employed to date are the subject of the next chapter, where simple intensity as well as lifetime- or wavelength-referenced schemes are presented and the utility of image-based sensing on the microscale is discussed. Lastly, exciting applications of these microfluidic chips are highlighted. Luminescent oxygen and pH sensing has been of particular interest in the field of microbioreactors but other areas are also of interest, particularly chemical reactors and electrophoresis. Optical temperature sensing is discussed and its use in fundamental studies as well as in enzyme reactors. Integrated microsystems with biosensing capabilities and some for monitoring of metal ions and other analytes are also presented.

  20. Warped C80H30 nanographene as a chemical sensor for CO gas: DFT studies

    Science.gov (United States)

    Jameh-Bozorghi, Saeed; Soleymanabadi, Hamed

    2017-02-01

    In 2013, synthesis of a grossly warped nanographene (C80H30, NG) which was reported in Nature Chemistry opens a new avenue in carbonaceous nanomaterial research. Here we investigated the chemical reactivity and electronic sensitivity of this NG to carbon monoxide (CO) gas, using density functional theory calculations. It was found that the CO molecule prefers to be added to a C-C bond at the center of NG similarly to the [ 2 + 2] addition. The calculated adsorption energy which is about -10.92 kJ/mol is accompanied by a natural bond orbitals (NBO) charge transfer of 0.21 e from the NG to the CO molecule. Unlike the graphene, the electronic properties of NG are significantly affected by the CO adsorption. After the CO adsorption, the electrical conductivity of the NG is considerably increased which can be converted to an electrical signal. Thus, it is concluded that the NG may be a potential compound for the CO chemical sensors for which the pristine graphene is not appropriate. We demonstrated that by increasing the concentration of the CO molecules the electrical conductivity is increased more. Also, a short recovery time of about 83 ps is predicted for NG sensor.

  1. Monitoring of Carbon Dioxide and Methane Plumes from Combined Ground-Airborne Sensors

    Science.gov (United States)

    Jacob, Jamey; Mitchell, Taylor; Honeycutt, Wes; Materer, Nicholas; Ley, Tyler; Clark, Peter

    2016-11-01

    A hybrid ground-airborne sensing network for real-time plume monitoring of CO2 and CH4 for carbon sequestration is investigated. Conventional soil gas monitoring has difficulty in distinguishing gas flux signals from leakage with those associated with meteorologically driven changes. A low-cost, lightweight sensor system has been developed and implemented onboard a small unmanned aircraft and is combined with a large-scale ground network that measures gas concentration. These are combined with other atmospheric diagnostics, including thermodynamic data and velocity from ultrasonic anemometers and multi-hole probes. To characterize the system behavior and verify its effectiveness, field tests have been conducted with simulated discharges of CO2 and CH4 from compressed gas tanks to mimic leaks and generate gaseous plumes, as well as field tests over the Farnsworth CO2-EOR site in the Anadarko Basin. Since the sensor response time is a function of vehicle airspeed, dynamic calibration models are required to determine accurate location of gas concentration in space and time. Comparisons are made between the two tests and results compared with historical models combining both flight and atmospheric dynamics. Supported by Department of Energy Award DE-FE0012173.

  2. Fiber optic chemical sensors: The evolution of high- density fiber-optic DNA microarrays

    Science.gov (United States)

    Ferguson, Jane A.

    2001-06-01

    Sensors were developed for multianalyte monitoring, fermentation monitoring, lactate analysis, remote oxygen detection for use in bioremediation monitoring and in a fuel spill clean-up project, heavy metal analysis, and high density DNA microarrays. The major focus of this thesis involved creating and improving high-density DNA gene arrays. Fiber optic sensors are created using fluorescent indicators, polymeric supports, and optical fiber substrates. The fluorescent indicator is entrapped in a polymer layer and attached to the tip of the optical fiber. The tip of the fiber bearing the sensing layer (the distal end) is placed in the sample of interest while the other end of the fiber (the proximal end) is connected to an analysis system. Any length of fiber can be used without compromising the integrity or sensitivity of the system. A fiber optic oxygen sensor was designed incorporating an oxygen sensitive fluorescent dye and a gas permeable polymer attached to an optical fiber. The construction simplicity and ruggedness of the sensor enabled its deployment for in situ chemical oxidation and bioremediation studies. Optical fibers were also used as the substrate to detect biomolecules in solution. To monitor bioprocesses, the production of the analyte of interest must be coupled with a species that is optically measurable. For example, oxygen is consumed in many metabolic functions. The fiber optic oxygen sensor is equipped with an additional sensing layer. Upon contact with a specific biochemical in the sample, a reaction occurs in the additional sensing layer that either consumes or produces oxygen. This dual layer system was used to monitor the presence of lactate, an important metabolite for clinical and bioprocess analysis. In many biological and environmental systems, the generation of one species occurs coincidentally with the generation or consumption of another species. A multianalyte sensor was prepared that can monitor the simultaneous activity of pH, CO2

  3. Chemical industrial wastewater treated by combined biological and chemical oxidation process.

    Science.gov (United States)

    Guomin, Cao; Guoping, Yang; Mei, Sheng; Yongjian, Wang

    2009-01-01

    Wastewaters from phenol and rubber synthesis were treated by the activated sludge process in a large-scale chemical factory in Shanghai, but the final effluent quality cannot conform with the local discharge limit without using river water for dilution. Therefore, this chemical factory had to upgrade its wastewater treatment plant. To fully use the present buildings and equipment during upgrading of the chemical factory's wastewater treatment plant and to save operation costs, a sequential biological pre-treatement, chemical oxidation, and biological post-treatment (or BCB for short) process had been proposed and investigated in a pilot trial. The pilot trial results showed that about 80% COD in the chemical wastewater could be removed through anoxic and aerobic degradation in the biological pre-treatement section, and the residual COD in the effluent of the biological pre-treatment section belongs to refractory chemicals which cannot be removed by the normal biological process. The refractory chemicals were partial oxidized using Fenton's reagent in the chemical oxidation section to improve their biodegradability; subsequently the wastewater was treated by the SBR process in the biological post-treatment section. The final effluent COD reached the first grade discharge limit (process, the operation cost of the BCB process increased by about 0.5 yuan (RMB) per cubic metre wastewater, but about 1,240,000 m(3) a(-1) dilution water could be saved and the COD emission could be cut down by 112 tonne each year.

  4. COMBINATION OF TLS POINT CLOUDS AND 3D DATA FROM KINECT V2 SENSOR TO COMPLETE INDOOR MODELS

    OpenAIRE

    E. Lachat; Landes, T.; P. Grussenmeyer

    2016-01-01

    The combination of data coming from multiple sensors is more and more applied for remote sensing issues (multi-sensor imagery) but also in cultural heritage or robotics, since it often results in increased robustness and accuracy of the final data. In this paper, the reconstruction of building elements such as window frames or door jambs scanned thanks to a low cost 3D sensor (Kinect v2) is presented. Their combination within a global point cloud of an indoor scene acquired with a terrestrial...

  5. Design and characterization of a novel sensor combined imaging and zinc ion sensing

    Science.gov (United States)

    Wang, Jian; Wang, Lili

    2012-05-01

    A novel fluorescent sensor for Zn(II) detection and imaging is developed by incorporating 1-(2-pyridylazo)-2-naphthol (PAN) and Rhodamine B (RB) in a sol-gel film on an end face of a gradient index (GRIN) lens rod which is tightly connected with an imaging fiber. This technique has high-quality imaging capabilities for observing remote sample while measuring Zn(II). The RB and PAN employed in combination as the indicator for zinc-sensing is much cheaper than that of the other zinc-sensitive fluorescent dyes. The sol is prepared by base catalyzed hydrolysis of tetraethylorthosilicate (TEOS) with the addition of 3-glycidyloxypropyltrimethoxysilane (GLYMO) and 3-aminopropyltriethoxysilane (APTES), which is more suitable for Zn(II) detection. The sensor has the linear range of Zn(II) from 0.1 to 1 mmol/L. Simultaneously, it has the capabilities of real-time imaging with the whole system's resolution of 18.73 line pairs/mm. This bi-functional sensor has potential applications in in situ biosensing and other remote measurements.

  6. Cell Recovery after Combined Action of Ionizing Radiation and Chemicals

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Kyu; Roh, Chang Hyun; Ryu, Tae Ho [Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of); Komarova, Ludmila N.; Petin, Vladislav G. [Medical Radiological Research Center, Obninsk (Russian Federation)

    2012-05-15

    Damage repair in malignant cells would be problematic in sterilization of microorganisms and treatment of cancer, as well. The inhibition of cell recovery and DNA single and double strand breaks repair by chemicals is expressed both as a deceleration of recovery rate and a lesser extent of recovery. Three possibilities are involved in the inhibition of cell recovery: (1) impairment of the recovery process itself, (2) increased irreversible damage, and (3) simultaneous exert of the two. There have been fee publications regarding these problems. The aim of this study was to determine which of these points are involved in the inhibition of cell recovery. In this study, a quantitative approach describing cell recovery from potentially lethal damage as a decrease in the effective dose was used

  7. Predictive monitoring of mobile patients by combining clinical observations with data from wearable sensors.

    Science.gov (United States)

    Clifton, Lei; Clifton, David A; Pimentel, Marco A F; Watkinson, Peter J; Tarassenko, Lionel

    2014-05-01

    The majority of patients in the hospital are ambulatory and would benefit significantly from predictive and personalized monitoring systems. Such patients are well suited to having their physiological condition monitored using low-power, minimally intrusive wearable sensors. Despite data-collection systems now being manufactured commercially, allowing physiological data to be acquired from mobile patients, little work has been undertaken on the use of the resultant data in a principled manner for robust patient care, including predictive monitoring. Most current devices generate so many false-positive alerts that devices cannot be used for routine clinical practice. This paper explores principled machine learning approaches to interpreting large quantities of continuously acquired, multivariate physiological data, using wearable patient monitors, where the goal is to provide early warning of serious physiological determination, such that a degree of predictive care may be provided. We adopt a one-class support vector machine formulation, proposing a formulation for determining the free parameters of the model using partial area under the ROC curve, a method arising from the unique requirements of performing online analysis with data from patient-worn sensors. There are few clinical evaluations of machine learning techniques in the literature, so we present results from a study at the Oxford University Hospitals NHS Trust devised to investigate the large-scale clinical use of patient-worn sensors for predictive monitoring in a ward with a high incidence of patient mortality. We show that our system can combine routine manual observations made by clinical staff with the continuous data acquired from wearable sensors. Practical considerations and recommendations based on our experiences of this clinical study are discussed, in the context of a framework for personalized monitoring.

  8. Chip Implementation with a Combined Wireless Temperature Sensor and Reference Devices Based on the DZTC Principle

    Directory of Open Access Journals (Sweden)

    Shey-Shi Lu

    2011-10-01

    Full Text Available This paper presents a novel CMOS wireless temperature sensor design in order to improve the sensitivity and linearity of our previous work on such devices. Based on the principle of CMOS double zero temperature coefficient (DZTC points, a combined device is first created at the chip level with two voltage references, one current reference, and one temperature sensor. It was successfully fabricated using the 0.35 μm CMOS process. According to the chip results in a wide temperature range from −20 °C to 120 °C, two voltage references can provide temperature-stable outputs of 823 mV and 1,265 mV with maximum deviations of 0.2 mV and 8.9 mV, respectively. The result for the current reference gives a measurement of 23.5 µA, with a maximum deviation of 1.2 µA. The measurements also show that the wireless temperature sensor has good sensitivity of 9.55 mV/°C and high linearity of 97%. The proposed temperature sensor has 4.15-times better sensitivity than the previous design. Moreover, to facilitate temperature data collection, standard wireless data transmission is chosen; therefore, an 8-bit successive-approximation-register (SAR analog-to-digital converter (ADC and a 433 MHz wireless transmitter are also integrated in this chip. Sensing data from different places can be collected remotely avoiding the need for complex wire lines.

  9. Combining structured light and ladar for pose tracking in THz sensor management

    Science.gov (United States)

    Engström, Philip; Axelsson, Maria; Karlsson, Mikael

    2013-05-01

    Stand-off 3D THz imaging to detect concealed treats is currently under development. The technology can provide high resolution 3D range data of a passing subject showing layers of clothes and if there are concealed items. However, because it is a scanning sensor technology with a narrow field of view, the subjects pose and position need to be accurately tracked in real time to focus the system and map the imaged THz data to specific body parts. Structured light is a technique to obtain 3D range information. It is, for example, used in the Microsoft Kinect for pose tracking of game players in real time. We demonstrate how structured light can contribute to a THz sensor management system and track subjects in real time. The main advantage of structured light is its simplicity, the disadvantages are the sensitivity to lighting conditions and material properties as well as a relatively low accuracy. Time of flight laser scanning is a technique that complements structured light well, the accuracy is usually much higher and it is less sensitive to lighting conditions. We show that by combining the techniques it is possible to create a robust real time pose tracking system for THz sensor management. We present a concept system based on the Microsoft Kinect and a SICK LMS-511 laser scanner. The laser scanner is used for 2D tracking of the subjects, this tracking is then used to initialize and validate the Microsoft Kinect pose tracking. We have evaluated the sensors individually in both static and dynamic scenes and present their advantages and drawbacks.

  10. Combined Chemical Activation and Fenton Degradation to Convert Waste Polyethylene into High-Value Fine Chemicals.

    Science.gov (United States)

    Chow, Cheuk-Fai; Wong, Wing-Leung; Ho, Keith Yat-Fung; Chan, Chung-Sum; Gong, Cheng-Bin

    2016-07-04

    Plastic waste is a valuable organic resource. However, proper technologies to recover usable materials from plastic are still very rare. Although the conversion/cracking/degradation of certain plastics into chemicals has drawn much attention, effective and selective cracking of the major waste plastic polyethylene is extremely difficult, with degradation of C-C/C-H bonds identified as the bottleneck. Pyrolysis, for example, is a nonselective degradation method used to crack plastics, but it requires a very high energy input. To solve the current plastic pollution crisis, more effective technologies are needed for converting plastic waste into useful substances that can be fed into the energy cycle or used to produce fine chemicals for industry. In this study, we demonstrate a new and effective chemical approach by using the Fenton reaction to convert polyethylene plastic waste into carboxylic acids under ambient conditions. Understanding the fundamentals of this new chemical process provides a possible protocol to solve global plastic-waste problems.

  11. Investigation on dielectrophoretic assembly of nanostructures and its application on chemical sensors

    Science.gov (United States)

    Tao, Quan

    Because of their extraordinary characteristics such as quantum confinement and large surface-tovolume ratio, semiconducting nanostructures such as nanowires or nanotubes hold great potential in sensing chemical vapors. Nanowire or nanotube based gas sensors usually possess appealing advantages such as high sensitivity, high stability, fast recovery time, and electrically controllable properties. To better predict the composition and concentration of target gas, nanostructures made from heterogeneous materials are employed to provide more predictors. In recent years, nanowires and nanotubes can be synthesized routinely through different methods. The techniques of fabricating nanowire or nanotube based sensor arrays, however, encounter obstacles and deserve further investigations. Dielectrophoresis (DEP), which refers to the motion of submicron particles inside a non-uniform electric field, has long been recognized as a nondestructive, easily implementable, and efficient approach to manipulate nanostructures onto electronic circuitries. However, due to our limited understandings, devices fabricated through DEP often end up with unpredictable number of arbitrarily aligned nanostructures. In this study, we first optimize the classical DEP formulas such that it can be applied to a more general case that a nanostructure is subjected to a non-uniform electric field with arbitrary orientation. A comprehensive model is then constructed to investigate the trajectory and alignment of DEP assembled nanostructures, which can be verified by experimental observations. The simulation results assist us to fabricate a gas sensor array with zinc oxide (ZnO) nanowires and carbon nanotubes (CNTs). It is then demonstrated that the device can well sense ammonia (NH3) at room temperature, which circumvents the usually required high temperature condition for nanowire based gas sensor application. An effective approach to recover the device using DC biases to locally heat up the

  12. Combined Ozone Retrieval From METOP Sensors Using META-Training Of Deep Neural Networks

    Science.gov (United States)

    Felder, Martin; Sehnke, Frank; Kaifel, Anton

    2013-12-01

    The newest installment of our well-proven Neural Net- work Ozone Retrieval System (NNORSY) combines the METOP sensors GOME-2 and IASI with cloud information from AVHRR. Through the use of advanced meta- learning techniques like automatic feature selection and automatic architecture search applied to a set of deep neural networks, having at least two or three hidden layers, we have been able to avoid many technical issues normally encountered during the construction of such a joint retrieval system. This has been made possible by harnessing the processing power of modern consumer graphics cards with high performance graphic processors (GPU), which decreases training times by about two orders of magnitude. The system was trained on data from 2009 and 2010, including target ozone profiles from ozone sondes, ACE- FTS and MLS-AURA. To make maximum use of tropospheric information in the spectra, the data were partitioned into several sets of different cloud fraction ranges with the GOME-2 FOV, on which specialized retrieval networks are being trained. For the final ozone retrieval processing the different specialized networks are combined. The resulting retrieval system is very stable and does not show any systematic dependence on solar zenith angle, scan angle or sensor degradation. We present several sensitivity studies with regard to cloud fraction and target sensor type, as well as the performance in several latitude bands and with respect to independent validation stations. A visual cross-comparison against high-resolution ozone profiles from the KNMI EUMETSAT Ozone SAF product has also been performed and shows some distinctive features which we will briefly discuss. Overall, we demonstrate that a complex retrieval system can now be constructed with a minimum of ma- chine learning knowledge, using automated algorithms for many design decisions previously requiring expert knowledge. Provided sufficient training data and computation power of GPUs is available, the

  13. Dynamic imaging of cytosolic zinc in Arabidopsis roots combining FRET sensors and RootChip technology.

    Science.gov (United States)

    Lanquar, Viviane; Grossmann, Guido; Vinkenborg, Jan L; Merkx, Maarten; Thomine, Sébastien; Frommer, Wolf B

    2014-04-01

    Zinc plays a central role in all living cells as a cofactor for enzymes and as a structural element enabling the adequate folding of proteins. In eukaryotic cells, metals are highly compartmentalized and chelated. Although essential to characterize the mechanisms of Zn(2+) homeostasis, the measurement of free metal concentrations in living cells has proved challenging and the dynamics are difficult to determine. Our work combines the use of genetically encoded Förster resonance energy transfer (FRET) sensors and a novel microfluidic technology, the RootChip, to monitor the dynamics of cytosolic Zn(2+) concentrations in Arabidopsis root cells. Our experiments provide estimates of cytosolic free Zn(2+) concentrations in Arabidopsis root cells grown under sufficient (0.4 nM) and excess (2 nM) Zn(2+) supply. In addition, monitoring the dynamics of cytosolic [Zn(2+) ] in response to external supply suggests the involvement of high- and low-affinity uptake systems as well as release from internal stores. In this study, we demonstrate that the combination of genetically encoded FRET sensors and microfluidics provides an attractive tool to monitor the dynamics of cellular metal ion concentrations over a wide concentration range in root cells. © 2013 The Authors. New Phytologist © 2013 New Phytologist Trust.

  14. Combination Adaptive Traffic Algorithm and Coordinated Sleeping in Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    M. Udin Harun Al Rasyid

    2014-12-01

    Full Text Available Wireless sensor network (WSN uses a battery as its primary power source, so that WSN will be limited to battery power for long operations. The WSN should be able to save the energy consumption in order to operate in a long time.WSN has the potential to be the future of wireless communications solutions. WSN are small but has a variety of functions that can help human life. WSN has the wide variety of sensors and can communicate quickly making it easier for people to obtain information accurately and quickly. In this study, we combine adaptive traffic algorithms and coordinated sleeping as power‐efficient WSN solution. We compared the performance of our proposed ideas combination adaptive traffic and coordinated sleeping algorithm with non‐adaptive scheme. From the simulation results, our proposed idea has good‐quality data transmission and more efficient in energy consumption, but it has higher delay than that of non‐adaptive scheme. Keywords:WSN,adaptive traffic,coordinated sleeping,beacon order,superframe order.

  15. Chemical-Biological Properties of Zinc Sensors TSQ and Zinquin: Formation of Sensor-Zn-Protein Adducts versus Zn(Sensor)2 Complexes.

    Science.gov (United States)

    Nowakowski, Andrew B; Meeusen, Jeffrey W; Menden, Heather; Tomasiewicz, Henry; Petering, David H

    2015-12-21

    Fluorescent zinc sensors are the most commonly used tool to study the intracellular mobile zinc status within cellular systems. Previously, we have shown that the quinoline-based sensors Zinquin and 6-methoxy-8-p-toluenesulfonamido-quinoline (TSQ) predominantly form ternary adducts with members of the Zn-proteome. Here, the chemistries of these sensors are further characterized, including how Zn(sensor)2 complexes may react in an intracellular environment. We demonstrate that these sensors are typically used in higher concentrations than needed to obtain maximum signal. Exposing cells to either Zn(Zinquin)2 or Zn(TSQ)2 resulted in efficient cellular uptake and the formation of sensor-Zn-protein adducts as evidenced by both a fluorescence spectral shift toward that of ternary adducts and the localization of the fluorescence signal within the proteome after gel filtration of cellular lysates. Likewise, reacting Zn(sensor)2 with the Zn-proteome from LLC-PK1 cells resulted in the formation of sensor-Zn-protein ternary adducts that could be inhibited by first saturating the Zn- proteome with excess sensor. Further, a native SDS-PAGE analysis of the Zn-proteome reacted with either the sensor or the Zn(sensor)2 complex revealed that both reactions result in the formation of a similar set of sensor-Zn-protein fluorescent products. The results of this experiment also demonstrated that TSQ and Zinquin react with different members of the Zn-proteome. Reactions with the model apo-Zn-protein bovine serum albumin showed that both Zn(TSQ)2 and Zn(Zinquin)2 reacted to form ternary adducts with its apo-Zn-binding site. Moreover, incubating Zn(sensor)2 complexes with non-zinc binding proteins failed to elicit a spectral shift in the fluorescence spectrum, supporting the premise that blue-shifted emission spectra are due to sensor-Zn-protein ternary adducts. It was concluded that Zn(sensors)2 species do not play a significant role in the overall reaction between these sensors and

  16. Functionalised zinc oxide nanowire gas sensors: Enhanced NO2 gas sensor response by chemical modification of nanowire surfaces

    Directory of Open Access Journals (Sweden)

    Eric R. Waclawik

    2012-05-01

    Full Text Available Surface coating with an organic self-assembled monolayer (SAM can enhance surface reactions or the absorption of specific gases and hence improve the response of a metal oxide (MOx sensor toward particular target gases in the environment. In this study the effect of an adsorbed organic layer on the dynamic response of zinc oxide nanowire gas sensors was investigated. The effect of ZnO surface functionalisation by two different organic molecules, tris(hydroxymethylaminomethane (THMA and dodecanethiol (DT, was studied. The response towards ammonia, nitrous oxide and nitrogen dioxide was investigated for three sensor configurations, namely pure ZnO nanowires, organic-coated ZnO nanowires and ZnO nanowires covered with a sparse layer of organic-coated ZnO nanoparticles. Exposure of the nanowire sensors to the oxidising gas NO2 produced a significant and reproducible response. ZnO and THMA-coated ZnO nanowire sensors both readily detected NO2 down to a concentration in the very low ppm range. Notably, the THMA-coated nanowires consistently displayed a small, enhanced response to NO2 compared to uncoated ZnO nanowire sensors. At the lower concentration levels tested, ZnO nanowire sensors that were coated with THMA-capped ZnO nanoparticles were found to exhibit the greatest enhanced response. ΔR/R was two times greater than that for the as-prepared ZnO nanowire sensors. It is proposed that the ΔR/R enhancement in this case originates from the changes induced in the depletion-layer width of the ZnO nanoparticles that bridge ZnO nanowires resulting from THMA ligand binding to the surface of the particle coating. The heightened response and selectivity to the NO2 target are positive results arising from the coating of these ZnO nanowire sensors with organic-SAM-functionalised ZnO nanoparticles.

  17. Performance of an electrochemical COD (chemical oxygen demand) sensor with an electrode-surface grinding unit.

    Science.gov (United States)

    Geun Jeong, Bong; Min Yoon, Seok; Ho Choi, Chang; Koang Kwon, Kil; Sik Hyun, Moon; Heui Yi, Dong; Soo Park, Hyung; Kim, Mia; Joo Kim, Hyung

    2007-12-01

    An electrochemical COD (chemical oxygen demand) sensor using an electrode-surface grinding unit was investigated. The electrolyzing (oxidizing) action of copper on an organic species was used as the basis of the COD measuring sensor. Using a simple three-electrode cell and a surface grinding unit, the organic species is activated by the catalytic action of copper and oxidized at a working electrode, poised at a positive potential. When synthetic wastewater was fed into the system, the measured Coulombic yields were found to be dependent on the COD of the synthetic wastewater. A linear correlation between the Coulombic yields and the COD of the synthetic wastewater was established (10-1000 mg L(-1)) when the electrode-surface grinding procedure was activated briefly at 8 h intervals. When various kinds of wastewater samples obtained from various sewage treatment plants were measured, linear correlations (r(2)> or = 0.92) between the measured EOD (electrochemical oxygen demand) value and COD of the samples were observed. At a practical wastewater treatment plant, the measurement system was successfully operated with high accuracy and good stability over 3 months. These experimental results show that the application of the measurement system would be a rapid and practical method for the determination of COD in water industries.

  18. Silicon-based optoelectronic integrated circuit for label-free bio/chemical sensor.

    Science.gov (United States)

    Song, Junfeng; Luo, Xianshu; Kee, Jack Sheng; Han, Kyungsup; Li, Chao; Park, Mi Kyoung; Tu, Xiaoguang; Zhang, Huijuan; Fang, Qing; Jia, Lianxi; Yoon, Yong-Jin; Liow, Tsung-Yang; Yu, Mingbin; Lo, Guo-Qiang

    2013-07-29

    We demonstrate a silicon-based optoelectronic integrated circuit (OEIC) for label-free bio/chemical sensing application. Such on-chip OEIC sensor system consists of optical grating couplers for vertical light coupling into silicon waveguides, a thermal-tunable microring as a tunable filter, an exposed microring as an optical label-free sensor, and a Ge photodetector for a direct electrical readout. Different from the conventional wavelength-scanning method, we adopt low-cost broadband ASE light source, together with the on-chip tunable filter to generate sliced light source. The effective refractive index change of the sensing microring induced by the sensing target is traced by scanning the supplied electrical power applied onto the tracing microring, and the detected electrical signal is read out by the Ge photodetector. For bulk refractive index sensing, we demonstrate using such OEIC sensing system with a sensitivity of ~15 mW/RIU and a detection limit of 3.9 μ-RIU, while for surface sensing of biotin-streptavidin, we obtain a surface mass sensitivity of S(m) = ~192 µW/ng·mm(-2) and a surface detection limit of 0.3 pg/mm(2). The presented OEIC sensing system is suitable for point-of-care applications.

  19. Bioanalytical and chemical sensors using living taste, olfactory, and neural cells and tissues: a short review.

    Science.gov (United States)

    Wu, Chunsheng; Lillehoj, Peter B; Wang, Ping

    2015-11-01

    Biosensors utilizing living tissues and cells have recently gained significant attention as functional devices for chemical sensing and biochemical analysis. These devices integrate biological components (i.e. single cells, cell networks, tissues) with micro-electro-mechanical systems (MEMS)-based sensors and transducers. Various types of cells and tissues derived from natural and bioengineered sources have been used as recognition and sensing elements, which are generally characterized by high sensitivity and specificity. This review summarizes the state of the art in tissue- and cell-based biosensing platforms with an emphasis on those using taste, olfactory, and neural cells and tissues. Many of these devices employ unique integration strategies and sensing schemes based on sensitive transducers including microelectrode arrays (MEAs), field effect transistors (FETs), and light-addressable potentiometric sensors (LAPSs). Several groups have coupled these hybrid biosensors with microfluidics which offers added benefits of small sample volumes and enhanced automation. While this technology is currently limited to lab settings due to the limited stability of living biological components, further research to enhance their robustness will enable these devices to be employed in field and clinical settings.

  20. A long period grating-based chemical sensor insensitive to the influence of interfering parameters.

    Science.gov (United States)

    James, Stephen W; Korposh, Serhiy; Lee, Seung-Woo; Tatam, Ralph P

    2014-04-07

    An optical fibre chemical sensor that is insensitive to interfering parameters including temperature and surrounding refractive index is described. The sensor is based upon a Mach-Zehnder interferometer formed by a pair of identical cascaded long period gratings (LPGs), with the entire device coated with a mesoporous coating of silica nanoparticles. A functional material is infused only into the coating over the section of optical fibre separating the LPGs. The transmission spectrum of the device consists of a channeled spectrum arising from interference of the core and cladding modes within the envelope of the LPG resonance band. Parameters such as temperature, strain and surrounding refractive perturb the entire device, causing the phase of the channeled spectrum and the central wavelength of the envelope shift at the same rate. Exposure of the device to the analyte of interest perturbs only the optical characteristics of the section of fibre into which the functional material was infused, thus influencing only the phase of the channeled spectrum. Measurement of the phase of the channeled spectrum relative to the central wavelength of the envelope allows the monitoring of the concentration of the analyte with no interference from other parameters.

  1. Novel semiconductor materials for the development of chemical sensors and biosensors: A review

    Energy Technology Data Exchange (ETDEWEB)

    Chaniotakis, Nikos [Laboratory of Analytical Chemistry, Department of Chemistry, University of Crete, Voutes 71003 Iraklion, Crete (Greece)], E-mail: nchan@chemistry.uoc.gr; Sofikiti, Nikoletta [Laboratory of Analytical Chemistry, Department of Chemistry, University of Crete, Voutes 71003 Iraklion, Crete (Greece)

    2008-05-12

    The aim of this manuscript is to provide a condensed overview of the contribution of certain relatively new semiconductor substrates in the development of chemical and biochemical field effect transistors. The silicon era is initially reviewed providing the background onto which the deployment of the new semiconductor materials for the development of bio-chem-FETs is based on. Subsequently emphasis is given to the selective interaction of novel semiconductor surfaces, including doped conductive diamond, gallium nitride, and indium nitride, with the analyte, and how this interaction can be properly transduced using semiconductor technology. The main advantages and drawbacks of these materials, as well as their future prospects for their applications in the sensor area are also described.

  2. Characteristics and Mechanisms in Ion-Conducting Polymer Films as Chemical Sensors

    Energy Technology Data Exchange (ETDEWEB)

    HUGHES,ROBERT C.; YELTON,WILLIAM G.; PFEIFER,KENT B.; PATEL,SANJAY V.

    2000-07-12

    Solid Polymer Electrolytes (SPE) are widely used in batteries and fuel cells because of the high ionic conductivity that can be achieved at room temperature. The ions are usually Li or protons, although other ions can be shown to conduct in these polymer films. There has been very little published work on SPE films used as chemical sensors. The authors have found that thin films of polymers like polyethylene oxide (PEO) are very sensitive to low concentrations of volatile organic compounds (VOCs) such as common solvents. Evidence of a new sensing mechanism involving the percolation of ions through narrow channels of amorphous polymer is presented. They present impedance spectroscopy of PEO films in the frequency range 0.0001 Hz to 1 MHz for different concentrations of VOCs and relative humidity. They find that the measurement frequency is important for distinguishing ionic conductivity from the double layer capacitance and the parasitic capacitance.

  3. Combined physical and chemical nonequilibrium transport model: Analytical solution, moments, and application to colloids

    Science.gov (United States)

    The transport of solutes and colloids in porous media is influenced by a variety of physical and chemical nonequilibrium processes. A combined physical–chemical nonequilibrium (PCNE) model was therefore used to describe general mass transport. The model partitions the pore space into “mobile” and “i...

  4. Research on Crude Oil Demulsification Using the Combined Method of Ultrasound and Chemical Demulsifier

    National Research Council Canada - National Science Library

    Mingxu Yi; Jun Huang; Lifeng Wang

    2017-01-01

    In this paper, experiments of crude oil demulsification using ultrasound, chemical demulsifier, and the combined method of ultrasound and chemical demulsifier, respectively, at different temperatures (40°C, 60°C, and 70°C) are carried out...

  5. Sample preparation for combined chemical analysis and bioassay application in water quality assessment

    NARCIS (Netherlands)

    Kolkman, A.; Schriks, M.; Brand, W; Bäuerlein, P.S.; van der Kooi, M.M.E.; van Doorn, R.H.; Emke, E.; Reus, A.; van der Linden, S.; de Voogt, P.; Heringa, M.B.

    2013-01-01

    The combination of in vitro bioassays and chemical screening can provide a powerful toolbox to determine biologically relevant compounds in water extracts. In this study, a sample preparation method is evaluated for the suitability for both chemical analysis and in vitro bioassays. A set of 39 chemi

  6. Adaptive Opportunistic Cooperative Control Mechanism Based on Combination Forecasting and Multilevel Sensing Technology of Sensors for Mobile Internet of Things

    Directory of Open Access Journals (Sweden)

    Yong Jin

    2014-01-01

    Full Text Available In mobile Internet of Things, there are many challenges, including sensing technology of sensors, how and when to join cooperative transmission, and how to select the cooperative sensors. To address these problems, we studied the combination forecasting based on the multilevel sensing technology of sensors, building upon which we proposed the adaptive opportunistic cooperative control mechanism based on the threshold values such as activity probability, distance, transmitting power, and number of relay sensors, in consideration of signal to noise ratio and outage probability. More importantly, the relay sensors would do self-test real time in order to judge whether to join the cooperative transmission, for maintaining the optimal cooperative transmission state with high performance. The mathematical analyses results show that the proposed adaptive opportunistic cooperative control approach could perform better in terms of throughput ratio, packet error rate and delay, and energy efficiency, compared with the direct transmission and opportunistic cooperative approaches.

  7. An approach for the calibration of a combined RGB-sensor and 3D-camera device

    Science.gov (United States)

    Schulze, M.

    2011-07-01

    The elds of application for 3d cameras are very dierent, because high image frequency and determination of 3d data. Often, 3d cameras are used for mobile robotic. They are used for obstacle detection or object recognition. So they also are interesting for applications in agriculture, in combination with mobile robots. Here, in addition to 3d data, there is often a necessity to get color information for each 3d point. Unfortunately, 3d cameras do not capture any color information. Therefore, an additional sensor is necessary, such as RGB plus possibly NIR. To combine data of two dierent sensors a reference to each other, via calibration, is important. This paper presents several calibration methods and discuss their accuracy potential. Based on a spatial resection, the algorithm determines the translation and rotation between the two sensors and the inner orientation of the used sensor.

  8. Combination of Tls Point Clouds and 3d Data from Kinect v2 Sensor to Complete Indoor Models

    Science.gov (United States)

    Lachat, E.; Landes, T.; Grussenmeyer, P.

    2016-06-01

    The combination of data coming from multiple sensors is more and more applied for remote sensing issues (multi-sensor imagery) but also in cultural heritage or robotics, since it often results in increased robustness and accuracy of the final data. In this paper, the reconstruction of building elements such as window frames or door jambs scanned thanks to a low cost 3D sensor (Kinect v2) is presented. Their combination within a global point cloud of an indoor scene acquired with a terrestrial laser scanner (TLS) is considered. If the added elements acquired with the Kinect sensor enable to reach a better level of detail of the final model, an adapted acquisition protocol may also provide several benefits as for example time gain. The paper aims at analyzing whether the two measurement techniques can be complementary in this context. The limitations encountered during the acquisition and reconstruction steps are also investigated.

  9. COMBINATION OF TLS POINT CLOUDS AND 3D DATA FROM KINECT V2 SENSOR TO COMPLETE INDOOR MODELS

    Directory of Open Access Journals (Sweden)

    E. Lachat

    2016-06-01

    Full Text Available The combination of data coming from multiple sensors is more and more applied for remote sensing issues (multi-sensor imagery but also in cultural heritage or robotics, since it often results in increased robustness and accuracy of the final data. In this paper, the reconstruction of building elements such as window frames or door jambs scanned thanks to a low cost 3D sensor (Kinect v2 is presented. Their combination within a global point cloud of an indoor scene acquired with a terrestrial laser scanner (TLS is considered. If the added elements acquired with the Kinect sensor enable to reach a better level of detail of the final model, an adapted acquisition protocol may also provide several benefits as for example time gain. The paper aims at analyzing whether the two measurement techniques can be complementary in this context. The limitations encountered during the acquisition and reconstruction steps are also investigated.

  10. Ionic liquids as green solvents and electrolytes for robust chemical sensor development.

    Science.gov (United States)

    Rehman, Abdul; Zeng, Xiangqun

    2012-10-16

    Ionic liquids (ILs) exhibit complex behavior. Their simultaneous dual nature as solvents and electrolytes supports the existence of structurally tunable cations and anions, which could provide the basis of a novel sensing technology. However, the elucidation of the physiochemical properties of ILs and their connections with the interaction and redox mechanisms of the target analytes requires concerted data acquired from techniques including spectroscopic investigations, thermodynamic and solvation models, and molecular simulations. Our laboratory is using these techniques for the rational design and selection of ILs and their composites that could serve as the recognition elements in various sensing platforms. ILs show equal utility in both piezoelectric and electrochemical formats through functionalized ionics that provide orthogonal chemo- and regioselectivity. In this Account, we summarize recent developments in and applications of task-specific ILs and their surface immobilization on solid supports. Such materials can serve as a replacement for conventional recognition elements and electrolytic media in piezoelectric and electrochemical sensing approaches, and we place a special focus on our contributions to these fields. ILs take advantage of both the physical and chemical forces of interaction and can incorporate various gas analytes. Exploiting these features, we have designed piezoelectric sensors and sensor arrays for high-temperature applications. Vibrational spectroscopy of these ILs reveals that hydrogen bonding and dipole-dipole interactions are typically responsible for the observed sensing profiles, but the polarization and cavity formation effect as an analyte approaches the recognition matrix can also cause selective discrimination. IL piezoelectric sensors can have low sensitivity and reproducibility. To address these issues, we designed IL/conducting polymer host systems that tune existing molecular templates with highly selective structure

  11. Single Particle Analysis by Combined Chemical Imaging to Study Episodic Air Pollution Events in Vienna

    Science.gov (United States)

    Ofner, Johannes; Eitenberger, Elisabeth; Friedbacher, Gernot; Brenner, Florian; Hutter, Herbert; Schauer, Gerhard; Kistler, Magdalena; Greilinger, Marion; Lohninger, Hans; Lendl, Bernhard; Kasper-Giebl, Anne

    2017-04-01

    The aerosol composition of a city like Vienna is characterized by a complex interaction of local emissions and atmospheric input on a regional and continental scale. The identification of major aerosol constituents for basic source appointment and air quality issues needs a high analytical effort. Exceptional episodic air pollution events strongly change the typical aerosol composition of a city like Vienna on a time-scale of few hours to several days. Analyzing the chemistry of particulate matter from these events is often hampered by the sampling time and related sample amount necessary to apply the full range of bulk analytical methods needed for chemical characterization. Additionally, morphological and single particle features are hardly accessible. Chemical Imaging evolved to a powerful tool for image-based chemical analysis of complex samples. As a complementary technique to bulk analytical methods, chemical imaging can address a new access to study air pollution events by obtaining major aerosol constituents with single particle features at high temporal resolutions and small sample volumes. The analysis of the chemical imaging datasets is assisted by multivariate statistics with the benefit of image-based chemical structure determination for direct aerosol source appointment. A novel approach in chemical imaging is combined chemical imaging or so-called multisensor hyperspectral imaging, involving elemental imaging (electron microscopy-based energy dispersive X-ray imaging), vibrational imaging (Raman micro-spectroscopy) and mass spectrometric imaging (Time-of-Flight Secondary Ion Mass Spectrometry) with subsequent combined multivariate analytics. Combined chemical imaging of precipitated aerosol particles will be demonstrated by the following examples of air pollution events in Vienna: Exceptional episodic events like the transformation of Saharan dust by the impact of the city of Vienna will be discussed and compared to samples obtained at a high alpine

  12. COMPARISON OF PERFORMANCE PIEZO RESONATORS BAW-TYPE TO CREATE CHEMICAL SENSOR

    Directory of Open Access Journals (Sweden)

    T. A. Kuchmenko

    2014-01-01

    Full Text Available Summary. Currently creation of small inexpensive analytical devices is very actual. Possibility of miniaturization vibrational gas sensors is associated with the possibility of using resonators smaller than the traditionally used sizes. The study used two types of sensors: sensors based on BAW resonators brand RK 169 with frequency of self-oscillation of 10 MHz and a mini - sensors, resonators based on BAW resonators brand MBC 10000 and MBC 15000 with frequencies of self-oscillation of 10 and 15 MHz respectively. As modifier of electrodes polyethylene glycol PEG 2000 was used. Check of sensitivity of microbalance and evaluation other performance properties of sensors was carried in pairs chloroform, 2-propanol and benzene. Mini -sensor has a smaller surface available sorption, whereby mini-sesors have a smaller analytical signal as compared traditional used resonators. Mass of coating which cause failure of self-oscillation for mini -sensors does not exceed 3 mcg and it is much smaller than for traditionally used sensors. It has been established that the analytical signal of mini-sensors in pairs of test compounds is higher than analytical signal of traditionally used sensors. Analytical signal is more for sensors with higher mass of coating and for sensors with higher selfoscillation frequency. The study found that the mini-sensors can be used for a narrow range of problems in the analysis. the sensitivity of mini-sensors is higher than that traditionally used sensors, but they have significant limitations on weight of coating.

  13. Combined optical fiber interferometric sensors for the detection of acoustic emission

    Institute of Scientific and Technical Information of China (English)

    LIANG Yi-jun; MU Lin-lin; LIU Jun-feng; YU Xiao-tao

    2008-01-01

    A type of combined optical fiber interferometric acoustic emission sensor is proposed.The sensor can be independent on the laser source and make light interference by matching the lengths of two arms,so it can be used to monitor the health of large structure.Theoretical analyses indicate that the system can be equivalent to the Michelson interferometer with two optical fiber loop reflectors,and its sensitivity has been remarkably increased because of the decrease of the losses of light energy.PZT is powered by DC regulator to control the operating point of the system,so the system can accurately detect feeble vibration which is generated by ultrasonic waves propagating on the surface of solid.The amplitude and the frequency of feeble vibration signal are obtained by detecting the output light intensity of intefferometer and using Fourier transform technique.The results indicate that the system can be used to detect the acoustic emission signals by the frequency characteristics.

  14. Oil-water two-phase flow measurement with combined ultrasonic transducer and electrical sensors

    Science.gov (United States)

    Tan, Chao; Yuan, Ye; Dong, Xiaoxiao; Dong, Feng

    2016-12-01

    A combination of ultrasonic transducers operated in continuous mode and a conductance/capacitance sensor (UTCC) is proposed to estimate the individual flow velocities in oil-water two-phase flows. Based on the Doppler effect, the transducers measure the flow velocity and the conductance/capacitance sensor estimates the phase fraction. A set of theoretical correlations based on the boundary layer models of the oil-water two-phase flow was proposed to describe the velocity profile. The models were separately established for the dispersion flow and the separate flow. The superficial flow velocity of each phase is calculated with the velocity measured in the sampling volume of the ultrasonic transducer with the phase fraction through the velocity profile models. The measuring system of the UTCC was designed and experimentally verified on a multiphase flow loop. The results indicate that the proposed system and correlations estimate the overall flow velocity at an uncertainty of U J   =  0.038 m s-1, and the water superficial velocity at U Jw   =  0.026 m s-1, and oil superficial velocity at U Jo   =  0.034 m s-1. The influencing factors of uncertainty were analyzed.

  15. Sensor Fusion and Autonomy as a Powerful Combination for Biological Assessment in the Marine Environment

    Directory of Open Access Journals (Sweden)

    Mark A. Moline

    2016-02-01

    Full Text Available The ocean environment and the physical and biological processes that govern dynamics are complex. Sampling the ocean to better understand these processes is difficult given the temporal and spatial domains and sampling tools available. Biological systems are especially difficult as organisms possess behavior, operate at horizontal scales smaller than traditional shipboard sampling allows, and are often disturbed by the sampling platforms themselves. Sensors that measure biological processes have also generally not kept pace with the development of physical counterparts as their requirements are as complex as the target organisms. Here, we attempt to address this challenge by advocating the need for sensor-platform combinations to integrate and process data in real-time and develop data products that are useful in increasing sampling efficiencies. Too often, the data of interest is only garnered after post-processing after a sampling effort and the opportunity to use that information to guide sampling is lost. Here we demonstrate a new autonomous platform, where data are collected, analyzed, and data products are output in real-time to inform autonomous decision-making. This integrated capability allows for enhanced and informed sampling towards improving our understanding of the marine environment.

  16. Analysis of viscous losses in the chemical interface layer of Love wave sensors.

    Science.gov (United States)

    Jakoby, B; Vellekoop, M J

    2000-01-01

    Love waves have been introduced as highly effective devices for liquid-sensing applications. For chemical sensors, a microacoustic delay line featuring a multilayered waveguide supporting a generalised Love wave mode can be used in an oscillator setup. The top layer of the waveguide is a chemical interface, which selectively adsorbs certain target molecules in the adjacent liquid. The increase in mass density caused by adsorption can be detected as changes in the oscillation frequency. Commonly used interface materials show viscoelastic losses leading to an unwanted damping of the wave. To keep the signal-to-noise ratio high, the total insertion loss of the delay line should be kept as low as possible. Furthermore, it must not exceed a certain value to allow the electronic circuitry to sustain the oscillation. We analyzed the viscoelastic losses, which strongly depend on the frequency being used. By means of the proposed theoretical approach, the maximum thickness of the interface layer can be determined not to exceed the losses that can be handled by the driving electronics.

  17. Physical, chemical, and other data collected using meteorological sensors, secchi disk, transmissometer, and CTD casts from the AKADEMIK VERMADSKIY with support from the IDOE/POLYMODE (International Decade of Ocean Exploration / combination of USSR POLYGON project and US MODE) from 17 October 1976 to 21 October 1976 (NODC Accession 7700551)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Physical, chemical, and other data were collected using moored buoy from the Atlantic Ocean from May 4, 1975 to December 18, 1975. Data were contributed by the...

  18. Chemically extracted acellular allogeneic nerve graft combined with ciliary neurotrophic factor promotes sciatic nerve repair

    Institute of Scientific and Technical Information of China (English)

    Yanru Zhang; Hui Zhang; Kaka Katiella; Wenhua Huang

    2014-01-01

    A chemically extracted acellular allogeneic nerve graft can reduce postoperative immune re-jection, similar to an autologous nerve graft, and can guide neural regeneration. However, it remains poorly understood whether a chemically extracted acellular allogeneic nerve graft combined with neurotrophic factors provides a good local environment for neural regenera-tion. This study investigated the repair of injured rat sciatic nerve using a chemically extracted acellular allogeneic nerve graft combined with ciliary neurotrophic factor. An autologous nerve anastomosis group and a chemical acellular allogeneic nerve bridging group were prepared as controls. At 8 weeks after repair, sciatic functional index, evoked potential amplitude of the soleus muscle, triceps wet weight recovery rate, total number of myelinated nerve fibers and myelin sheath thickness were measured. For these indices, values in the three groups showed the autologous nerve anastomosis group > chemically extracted acellular nerve graft + ciliary neurotrophic factor group > chemical acellular allogeneic nerve bridging group. These results suggest that chemically extracted acellular nerve grafts combined with ciliary neurotrophic factor can repair sciatic nerve defects, and that this repair is inferior to autologous nerve anasto-mosis, but superior to chemically extracted acellular allogeneic nerve bridging alone.

  19. HIGHLY SELECTIVE SENSORS FOR CHEMICAL AND BIOLOGICAL WARFARE AGENTS, INSECTICIDES AND VOCS BASED ON A MOLECULAR SURFACE IMPRINTING TECHNIQUE

    Science.gov (United States)

    Abstract was given as an oral platform presentation at the Pittsburgh Conference, Orlando FL (March 5-9, 2006). Research described is the development of sensors based on molecular surface imprinting. Applications include the monitoring of chemical and biological agents and inse...

  20. Smart chemical sensors using ZnO semiconducting thin films for freshness detection of foods and beverages

    Science.gov (United States)

    Nanto, Hidehito; Kobayashi, Toshiki; Dougami, Naganori; Habara, Masaaki; Yamamoto, Hajime; Kusano, Eiji; Kinbara, Akira; Douguchi, Yoshiteru

    1998-07-01

    The sensitivity of the chemical sensor, based on the resistance change of Al2O3-doped and SnO2-doped ZnO (ZnO:Al and ZnO:SnO2) thin film, is studied for exposure to various gases. It is found that the ZnO:Al and ZnO:Sn thin film chemical sensor has a high sensitivity and excellent selectivity for amine (TMA and DMA) gas and ethanol gas, respectively. The ZnO:Al (5.0 wt%) thin film chemical sensor which exhibit a high sensitivity for exposure to odors from rotten sea foods, such as salmon, sea bream, oyster, squid and sardine, responds to the freshness change of these sea foods. The ZnO:SnO2 (78 wt%) thin film chemical sensor which exhibit a high sensitivity for exposure to aroma from alcohols, such as wine, Japanese sake, and whisky, responds to the freshness change of these alcohols.

  1. Microwave assisted rapid growth of Mg(OH){sub 2} nanosheet networks for ethanol chemical sensor application

    Energy Technology Data Exchange (ETDEWEB)

    Al-Hazmi, Faten [Department of Physics, College of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21569 (Saudi Arabia); Umar, Ahmad, E-mail: ahmadumar786@gmail.com [Promising Centre for Sensors and Electronic Devices (PCSED) and Centre for Advanced Materials and Nano-Research (CAMNR), Najran University, P.O. Box 1988, Najran 11001 (Saudi Arabia); Dar, G.N. [Promising Centre for Sensors and Electronic Devices (PCSED) and Centre for Advanced Materials and Nano-Research (CAMNR), Najran University, P.O. Box 1988, Najran 11001 (Saudi Arabia); Al-Ghamdi, A.A.; Al-Sayari, S.A. [Department of Physics, College of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21569 (Saudi Arabia); Al-Hajry, A. [Promising Centre for Sensors and Electronic Devices (PCSED) and Centre for Advanced Materials and Nano-Research (CAMNR), Najran University, P.O. Box 1988, Najran 11001 (Saudi Arabia); Department of Physics, College of Science and Arts, Najran University, P.O. Box 1988, Najran 11001 (Saudi Arabia); Kim, S.H. [Promising Centre for Sensors and Electronic Devices (PCSED) and Centre for Advanced Materials and Nano-Research (CAMNR), Najran University, P.O. Box 1988, Najran 11001 (Saudi Arabia); Al-Tuwirqi, Reem M. [Department of Physics, College of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21569 (Saudi Arabia); Alnowaiserb, Fowzia [Department of Chemistry, Faculty of Science, King Abdulaziz University, Jeddah (Saudi Arabia); El-Tantawy, Farid [Department of Physics, Faculty of Science, Suez Canal University, Ismailia (Egypt)

    2012-04-05

    Highlights: Black-Right-Pointing-Pointer A facile microwave-assisted synthesis and characterizations of magnesium hydroxide (Mg(OH){sub 2}) nanosheet networks. Black-Right-Pointing-Pointer Fabrication of ethanol sensor based on (Mg(OH){sub 2}) nanosheet networks. Black-Right-Pointing-Pointer Good sensitivity ({approx}3.991 {mu}A cm{sup -2} mM{sup -1}) and lower detection limit (5 {mu}M). Black-Right-Pointing-Pointer This research opens a way to utilize Mg(OH){sub 2} nanostructures for chemical sensors applications. - Abstract: This paper reports a facile microwave-assisted synthesis of magnesium hydroxide (Mg(OH){sub 2}) nanosheet networks and their utilization for the fabrication of efficient ethanol chemical sensor. The synthesized nanosheets networks were characterized in terms of their morphological, structural and optical properties using various analysis techniques such as field emission scanning electron microscopy (FESEM), X-ray diffraction pattern (XRD), Fourier transform infrared (FTIR) and UV-Vis spectroscopy. The detailed morphological and structural investigations reveal that the synthesized (Mg(OH){sub 2}) products are nanosheet networks, grown in high density, and possessing hexagonal crystal structure. The optical band gap of as-synthesized Mg(OH){sub 2} nanosheet networks was examined by UV-Vis absorption spectrum, and found to be 5.76 eV. The synthesized nanosheet networks were used as supporting matrices for the fabrication of I-V technique based efficient ethanol chemical sensor. The fabricated ethanol sensor based on nanosheet networks exhibits good sensitivity ({approx}3.991 {mu}A cm{sup -2} mM{sup -1}) and lower detection limit (5 {mu}M), with linearity (R = 0.9925) in short response time (10.0 s). This work demonstrate that the simply synthesized Mg(OH){sub 2} nanosheet networks can effectively be used for the fabrication of efficient ethanol chemical sensors.

  2. A signal combining technique based on channel shortening for cooperative sensor networks

    KAUST Repository

    Hussain, Syed Imtiaz

    2010-06-01

    The cooperative relaying process needs proper coordination among the communicating and the relaying nodes. This coordination and the required capabilities may not be available in some wireless systems, e.g. wireless sensor networks where the nodes are equipped with very basic communication hardware. In this paper, we consider a scenario where the source node transmits its signal to the destination through multiple relays in an uncoordinated fashion. The destination can capture the multiple copies of the transmitted signal through a Rake receiver. We analyze a situation where the number of Rake fingers N is less than that of the relaying nodes L. In this case, the receiver can combine N strongest signals out of L. The remaining signals will be lost and act as interference to the desired signal components. To tackle this problem, we develop a novel signal combining technique based on channel shortening. This technique proposes a processing block before the Rake reception which compresses the energy of L signal components over N branches while keeping the noise level at its minimum. The proposed scheme saves the system resources and makes the received signal compatible to the available hardware. Simulation results show that it outperforms the selection combining scheme. ©2010 IEEE.

  3. Improved detection of chemical substances from colorimetric sensor data using probabilistic machine learning

    DEFF Research Database (Denmark)

    Mølgaard, Lasse Lohilahti; Buus, Ole Thomsen; Larsen, Jan

    2017-01-01

    We present a data-driven machine learning approach to detect drug- and explosives-precursors using colorimetric sensor technology for air-sampling. The sensing technology has been developed in the context of the CRIM-TRACK project. At present a fully- integrated portable prototype for air sampling...... of the highly multi-variate data produced from the colorimetric chip a number of machine learning techniques are employed to provide reliable classification of target analytes from confounders found in the air streams. We demonstrate that a data-driven machine learning method using dimensionality reduction...... in combination with a probabilistic classifier makes it possible to produce informative features and a high detection rate of analytes. Furthermore, the probabilistic machine learning approach provides a means of automatically identifying unreliable measurements that could produce false predictions...

  4. Combination of cascade chemical reactions with graphene-DNA interaction to develop new strategy for biosensor fabrication.

    Science.gov (United States)

    Zhu, Xiaoli; Sun, Liya; Chen, Yangyang; Ye, Zonghuang; Shen, Zhongming; Li, Genxi

    2013-09-15

    Graphene, a single atom thick and two dimensional carbon nano-material, has been proven to possess many unique properties, one of which is the recent discovery that it can interact with single-stranded DNA through noncovalent π-π stacking. In this work, we demonstrate that a new strategy to fabricate many kinds of biosensors can be developed by combining this property with cascade chemical reactions. Taking the fabrication of glucose sensor as an example, while the detection target, glucose, may regulate the graphene-DNA interaction through three cascade chemical reactions, electrochemical techniques are employed to detect the target-regulated graphene-DNA interaction. Experimental results show that in a range from 5μM to 20mM, the glucose concentration is in a natural logarithm with the logarithm of the amperometric response, suggesting a best detection limit and detection range. The proposed biosensor also shows favorable selectivity, and it has the advantage of no need for labeling. What is more, by controlling the cascade chemical reactions, detection of a variety of other targets may be achieved, thus the strategy proposed in this work may have a wide application potential in the future.

  5. Effects of combining microbial and chemical insecticides on mortality of the Pecan Weevil (Coleoptera: Curculionidae).

    Science.gov (United States)

    Shapiro-Ilan, David I; Cottrell, Ted E; Wood, Bruce W

    2011-02-01

    The pecan weevil, Curculio caryae (Horn), is a key pest of pecan [Carya illinoinensis (Wangenh.) K. Koch]. Current control recommendations are based on chemical insecticide applications. Microbial control agents such as the entomopathogenic nematode, Steinernema carpocapsae (Weiser) and the fungus Beauveria bassiana (Balsamo) Vuillemin occur naturally in southeastern U.S. pecan orchards and have shown promise as alternative control agents for C. caryjae. Conceivably, the chemical and microbial agents occur simultaneously within pecan orchards or might be applied concurrently. The objective of this study was to determine the interactions between two chemical insecticides that are used in commercial C. caryae control (i.e., carbaryl and cypermethrin applied below field rates) and the microbial agents B. bassiana and S. carpocapsae. In laboratory experiments, pecan weevil larval or adult mortality was assessed after application of microbial or chemical treatments applied singly or in combination (microbial + chemical agent). The nature of interactions (antagonism, additivity, or synergy) in terms of weevil mortality was evaluated over 9 d (larvae) or 5 d (adults). Results for B. bassiana indicated synergistic activity with carbaryl and antagonism with cypermethrin in C. caryae larvae and adults. For S. carpocapsae, synergy was detected with both chemicals in C. caryae larvae, but only additive effects were detected in adult weevils. Our results indicate that the chemical-microbial combinations tested are compatible with the exception of B. bassiana and cypermethrin. In addition, combinations that exhibited synergistic interactions may provide enhanced C. caryae control in commercial field applications; thus, their potential merits further exploration.

  6. Development Of Hot Surface Polysilicon-Based Chemical Sensor And Actuator With Integrated Catalytic Micropatterns For Gas Sensing Applications

    Science.gov (United States)

    Vereshchagina, E.; Gardeniers, J. G. E.

    2009-05-01

    Over the last twenty years, we have followed a rapid expansion in the development of chemical sensors and microreactors for detection and analysis of volatile organic compounds. However, for many of the developed gas sensors poor sensitivity and selectivity, and high-power consumption remain among one of the main drawbacks. One promising approach to increase selectivity at lower power consumption is calorimetric sensing, performed in a pulsed regime and using specific catalytic materials. In this work, we study kinetics of various catalytic oxidation reactions using micromachined hot surface polysilicon-based sensor containing sensitive and selective catalysts. The sensor acts as both thermal actuator of chemical and biochemical reactions on hot-surfaces and detector of heats (enthalpies) associated with these reactions. Using novel deposition techniques we integrated selective catalysts in an array of hot plates such that they can be thermally actuated and sensed individually. This allows selective detection and analysis of dangerous gas compounds in a mixture, specifically hydrocarbons at concentrations down to low ppm level. In this contribution we compare various techniques for the local immobilization of catalytic material on hot spots of the sensor in terms of process compatibility, mechanical stress, stability and cost.

  7. A sensitive and selective molecularly imprinted sensor combined with magnetic molecularly imprinted solid phase extraction for determination of dibutyl phthalate.

    Science.gov (United States)

    Zhang, Zhaohui; Luo, Lijuan; Cai, Rong; Chen, Hongjun

    2013-11-15

    A highly sensitive and selective molecularly imprinted (MIP) sensor combined with magnetic molecularly imprinted solid phase extraction (MMISPE) was developed for the determination of dibutyl phthalate (DBP) in complex matrixes. The magnetic molecularly imprinted polymer (MMIP) was synthesized as solid phase extraction (SPE) sorbet to extract DBP from complex matrixes and as sensing element to improve the selectivity of the imprinted sensor. The morphologies of MMIP and MIP-sensor were characterized by using scanning electron microscope (SEM) and transmission electron microscopy (TEM). The electrochemical performances of MIP-sensor were investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The conditions of preconcentration, elution and electrochemical determination were studied in detail. Under the optimized experimental conditions, the response currents of the MIP-sensor exhibited a linear relationship towards DBP concentrations ranging from 1.0 × 10(-8)g/L to 1.0 × 10(-3)g/L. The limit of detection of the MMIP-sensor coupled with the MMISPE was calculated as 0.052 ng/L. The MMIP-sensor coupled with the MMISPE was applied to detect DBP in complex samples successfully.

  8. Fabrication of smart chemical sensors based on transition-doped-semiconductor nanostructure materials with µ-chips.

    Science.gov (United States)

    Rahman, Mohammed M; Khan, Sher Bahadar; Asiri, Abdullah M

    2014-01-01

    Transition metal doped semiconductor nanostructure materials (Sb2O3 doped ZnO microflowers, MFs) are deposited onto tiny µ-chip (surface area, ∼0.02217 cm(2)) to fabricate a smart chemical sensor for toxic ethanol in phosphate buffer solution (0.1 M PBS). The fabricated chemi-sensor is also exhibited higher sensitivity, large-dynamic concentration ranges, long-term stability, and improved electrochemical performances towards ethanol. The calibration plot is linear (r(2) = 0.9989) over the large ethanol concentration ranges (0.17 mM to 0.85 M). The sensitivity and detection limit is ∼5.845 µAcm(-2)mM(-1) and ∼0.11±0.02 mM (signal-to-noise ratio, at a SNR of 3) respectively. Here, doped MFs are prepared by a wet-chemical process using reducing agents in alkaline medium, which characterized by UV/vis., FT-IR, Raman, X-ray photoelectron spectroscopy (XPS), powder X-ray diffraction (XRD), and field-emission scanning electron microscopy (FE-SEM) etc. The fabricated ethanol chemical sensor using Sb2O3-ZnO MFs is simple, reliable, low-sample volume (<70.0 µL), easy of integration, high sensitivity, and excellent stability for the fabrication of efficient I-V sensors on μ-chips.

  9. Information Theory and Voting Based Consensus Clustering for Combining Multiple Clusterings of Chemical Structures.

    Science.gov (United States)

    Saeed, Faisal; Salim, Naomie; Abdo, Ammar

    2013-07-01

    Many consensus clustering methods have been applied in different areas such as pattern recognition, machine learning, information theory and bioinformatics. However, few methods have been used for chemical compounds clustering. In this paper, an information theory and voting based algorithm (Adaptive Cumulative Voting-based Aggregation Algorithm A-CVAA) was examined for combining multiple clusterings of chemical structures. The effectiveness of clusterings was evaluated based on the ability of the clustering method to separate active from inactive molecules in each cluster, and the results were compared with Ward's method. The chemical dataset MDL Drug Data Report (MDDR) and the Maximum Unbiased Validation (MUV) dataset were used. Experiments suggest that the adaptive cumulative voting-based consensus method can improve the effectiveness of combining multiple clusterings of chemical structures.

  10. Handheld multi-channel LAPS device as a transducer platform for possible biological and chemical multi-sensor applications

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Torsten [Aachen University of Applied Sciences, Juelich Campus, Institute of Nano- and Biotechnologies, Ginsterweg 1, 52428 Juelich (Germany); Institute of Bio- and Nanosystems (IBN-2), Research Centre Juelich GmbH, 52425 Juelich (Germany); Molina, Roberto [Aachen University of Applied Sciences, Juelich Campus, Institute of Nano- and Biotechnologies, Ginsterweg 1, 52428 Juelich (Germany); Yoshinobu, Tatsuo [Tohoku University, Department of Electronic Engineering, 6-6-05 Aramaki Aza Aoba, Aoba-ku, Sendai, Miyagi 980-8579 (Japan); Kloock, Joachim P. [Aachen University of Applied Sciences, Juelich Campus, Institute of Nano- and Biotechnologies, Ginsterweg 1, 52428 Juelich (Germany); Institute of Bio- and Nanosystems (IBN-2), Research Centre Juelich GmbH, 52425 Juelich (Germany); Biselli, Manfred; Canzoneri, Michelangelo; Schnitzler, Thomas [Aachen University of Applied Sciences, Juelich Campus, Institute of Nano- and Biotechnologies, Ginsterweg 1, 52428 Juelich (Germany); Schoening, Michael J. [Aachen University of Applied Sciences, Juelich Campus, Institute of Nano- and Biotechnologies, Ginsterweg 1, 52428 Juelich (Germany); Institute of Bio- and Nanosystems (IBN-2), Research Centre Juelich GmbH, 52425 Juelich (Germany)], E-mail: m.j.schoening@fz-juelich.de

    2007-12-01

    The light-addressable potentiometric sensor is a promising technology platform for multi-sensor applications and lab-on-chip devices. However, many prior LAPS developments suffer from their lack in terms of non-portability, insufficient robustness, complicate handling, etc. Hence, portable and robust LAPS-based measurement devices have been investigated by the authors recently. In this work, a 'chip card'-based light-addressable potentiometric sensor system is presented. The utilisation of ordinary 'chip cards' allows an easy handling of different sensor chips for a wide range of possible applications. The integration of the electronic and the mechanical set-up into a single reader unit results in a compact design with the benefits of portability and low required space. In addition, the presented work includes a new multi-frequency measurement procedure, based on an FFT algorithm, which enables the simultaneous real-time measurement of up to 16 sensor spots. The comparison between the former batch-LAPS and the new FFT-based LAPS set-up will be presented. The immobilisation of biological cells (CHO: Chinese hamster ovary) demonstrates the possibility to record their metabolic activity with 16 measurement spots on the same chip. Furthermore, a Cd{sup 2+}-selective chalcogenide-glass layer together with a pH-sensitive Ta{sub 2}O{sub 5} layer validates the use of the LAPS for chemical multi-sensor applications.

  11. High-performance room-temperature hydrogen sensors based on combined effects of Pd decoration and Schottky barriers

    Science.gov (United States)

    Liu, Bin; Cai, Daoping; Liu, Yuan; Li, Han; Weng, Chao; Zeng, Guoshi; Li, Qiuhong; Wang, Taihong

    2013-02-01

    A new hydrogen sensor was fabricated by coating a Pd-decorated In2O3 film on Au electrodes. In response to 1 vol% H2 at room temperature, an ultra high sensitivity of 4.6 × 107 was achieved. But after an annealing treatment in vacuum, its sensitivity degenerated by 4 orders of magnitude. In addition, the response time and recovery time were also extended from 28 s and 32 s to 242 s and 108 s, respectively. It was found from contrast experiments that Pd decoration was essential to make the sensor work at room temperature and Schottky barriers played a vital role in enhancing the sensor's performance. The methodology demonstrated in this paper shows that a combination of novel sensing materials and Schottky contact is an effective approach to design high-performance gas sensors.A new hydrogen sensor was fabricated by coating a Pd-decorated In2O3 film on Au electrodes. In response to 1 vol% H2 at room temperature, an ultra high sensitivity of 4.6 × 107 was achieved. But after an annealing treatment in vacuum, its sensitivity degenerated by 4 orders of magnitude. In addition, the response time and recovery time were also extended from 28 s and 32 s to 242 s and 108 s, respectively. It was found from contrast experiments that Pd decoration was essential to make the sensor work at room temperature and Schottky barriers played a vital role in enhancing the sensor's performance. The methodology demonstrated in this paper shows that a combination of novel sensing materials and Schottky contact is an effective approach to design high-performance gas sensors. Electronic supplementary information (ESI) available: Hydrogen sensing test details and detailed material characterizations before and after the annealing treatment at 120 °C. See DOI: 10.1039/c3nr33872j

  12. Combining Wireless Sensor Networks and Groundwater Transport Models: Protocol and Model Development in a Simulative Environment

    Science.gov (United States)

    Barnhart, K.; Urteaga, I.; Han, Q.; Porta, L.; Jayasumana, A.; Illangasekare, T.

    2007-12-01

    Groundwater transport modeling is intended to aid in remediation processes by providing prediction of plume location and by helping to bridge data gaps in the typically undersampled subsurface environment. Increased availability of computer resources has made computer-based transport models almost ubiquitous in calculating health risks, determining cleanup strategies, guiding environmental regulatory policy, and in determining culpable parties in lawsuits. Despite their broad use, very few studies exist which verify model correctness or even usefulness, and those that have shown significant discrepancies between predicted and actual results. Better predictions can only be gained from additional and higher quality data, but this is an expensive proposition using current sampling techniques. A promising technology is the use of wireless sensor networks (WSNs) which are comprised of wireless nodes (motes) coupled to in-situ sensors that are capable of measuring hydrological parameters. As the motes are typically battery powered, power consumption is a major concern in routing algorithms. By supplying predictions about the direction and arrival time of the contaminant, the application-driven routing protocol would then become more efficient. A symbiotic relationship then exists between the WSN, which is supplying the data to calibrate the transport model, and the model, which may be supplying predictive information to the WSN for optimum monitoring performance. Many challenges exist before the above can be realized: WSN protocols must mature, as must sensor technology, and inverse models and tools must be developed for integration into the system. As current model calibration, even automatic calibration, still often requires manual tweaking of calibration parameters, implementing this in a real-time closed-loop process may require significant work. Based on insights from a previous proof-of-concept intermediate-scale tank experiment, we are developing the models, tools

  13. Research on the Interaction of Hydrogen-Bond Acidic Polymer Sensitive Sensor Materials with Chemical Warfare Agents Simulants by Inverse Gas Chromatography

    OpenAIRE

    Liu Yang; Qiang Han; Shuya Cao; Feng Huang; Molin Qin; Chenghai Guo; Mingyu Ding

    2015-01-01

    Hydrogen-bond acidic polymers are important high affinity materials sensitive to organophosphates in the chemical warfare agent sensor detection process. Interactions between the sensor sensitive materials and chemical warfare agent simulants were studied by inverse gas chromatography. Hydrogen bonded acidic polymers, i.e., BSP3, were prepared for micro-packed columns to examine the interaction. DMMP (a nerve gas simulant) and 2-CEES (a blister agent simulant) were used as probes. Chemical an...

  14. International Frameworks Dealing with Human Risk Assessment of Combined Exposure to Multiple Chemicals

    Directory of Open Access Journals (Sweden)

    European Food Safety Authority

    2013-07-01

    Full Text Available The development of harmonised terminology and frameworks for the human risk assessment of combined exposure to multiple chemicals (“chemical mixtures” is an important area for EFSA and a number of activities have already been undertaken, i.e. in the fields of pesticides and contaminants. The first step prior to a risk assessment of combined exposure to multiple chemicals is problem formulation defining the relevant exposure, hazard and population to be considered. In practice, risk assessment of multiple chemicals is conducted using a tiered approach for exposure assessment, hazard assessment and risk characterisation. Higher tiers require increasing knowledge about the group of chemicals under assessment and the tiers can range from tier 0 (default values, data poor situation to tier 3 (full probabilistic models. This scientific report reviews the terminology, methodologies and frameworks developed by national and international agencies for the human risk assessment of combined exposure to multiple chemicals and provides recommendations for future activities at EFSA in this area.

  15. Improved detection of chemical substances from colorimetric sensor data using probabilistic machine learning

    Science.gov (United States)

    Mølgaard, Lasse L.; Buus, Ole T.; Larsen, Jan; Babamoradi, Hamid; Thygesen, Ida L.; Laustsen, Milan; Munk, Jens Kristian; Dossi, Eleftheria; O'Keeffe, Caroline; Lässig, Lina; Tatlow, Sol; Sandström, Lars; Jakobsen, Mogens H.

    2017-05-01

    We present a data-driven machine learning approach to detect drug- and explosives-precursors using colorimetric sensor technology for air-sampling. The sensing technology has been developed in the context of the CRIM-TRACK project. At present a fully- integrated portable prototype for air sampling with disposable sensing chips and automated data acquisition has been developed. The prototype allows for fast, user-friendly sampling, which has made it possible to produce large datasets of colorimetric data for different target analytes in laboratory and simulated real-world application scenarios. To make use of the highly multi-variate data produced from the colorimetric chip a number of machine learning techniques are employed to provide reliable classification of target analytes from confounders found in the air streams. We demonstrate that a data-driven machine learning method using dimensionality reduction in combination with a probabilistic classifier makes it possible to produce informative features and a high detection rate of analytes. Furthermore, the probabilistic machine learning approach provides a means of automatically identifying unreliable measurements that could produce false predictions. The robustness of the colorimetric sensor has been evaluated in a series of experiments focusing on the amphetamine pre-cursor phenylacetone as well as the improvised explosives pre-cursor hydrogen peroxide. The analysis demonstrates that the system is able to detect analytes in clean air and mixed with substances that occur naturally in real-world sampling scenarios. The technology under development in CRIM-TRACK has the potential as an effective tool to control trafficking of illegal drugs, explosive detection, or in other law enforcement applications.

  16. Surface properties of solids and surface acoustic waves: Application to chemical sensors and layer characterization

    Science.gov (United States)

    Krylov, V. V.

    1995-09-01

    A general phenomenological approach is given for the description of mechanical surface properties of solids and their influence on surface acoustic wave propogation. Surface properties under consideration may be changes of the stress distribution in subsurface atomic layers, the presence of adsorbed gas molecules, surface degradation as a result of impacts from an aggressive environment, damage due to mechanical manufacturing or polishing, deposition of thin films or liquid layers, surface corrugations, etc. If the characteristic thickness of the affected layers is much less than the wavelengths of the propagating surface waves, then the effects of all these irregularities can be described by means of non-classical boundary conditions incorporating the integral surface parameters such as surface tension, surface moduli of elasticity and surface mass density. The effect of surface properties on the propagation of Rayleigh surface waves is analysed in comparison with the results of traditional approaches, in particular with Auld's energy perturbation method. One of the important implications of the above-mentioned boudnary conditions is that they are adequate for the description of the effect of rarely distributed adsorbed atoms or molecules. This allows, in particular, to obtain a rigorous theoretical description of chemical sensors using surface acoustic waves and to derive analytical expressions for their sensitivity.

  17. Life cycle impacts and benefits of a carbon nanotube-enabled chemical gas sensor.

    Science.gov (United States)

    Gilbertson, Leanne M; Busnaina, Ahmed A; Isaacs, Jacqueline A; Zimmerman, Julie B; Eckelman, Matthew J

    2014-10-07

    As for any emerging technology, it is critical to assess potential life cycle impacts prior to widespread adoption to prevent future unintended consequences. The subject of this life cycle study is a carbon nanotube-enabled chemical gas sensor, which is a highly complex, low nanomaterial-concentration application with the potential to impart significant human health benefits upon implementation. Thus, the net lifecycle trade-offs are quantified using an impact-benefit ratio (IBR) approach proposed herein, where an IBR < 1 indicates that the downstream benefits outweigh the upstream impacts. The cradle-to-gate assessment results indicate that the midpoint impacts associated with producing CNTs are marginal compared with those associated with the other manufacturing stages. The cumulative upstream impacts are further aggregated to units of disability-adjusted life years (DALYs) using ReCiPe end point analysis method and quantitatively compared with the potential downstream DALY benefits, as lives saved, during the use phase. The approach presented in this study provides a guiding framework and quantitative method intended to encourage the development of nanoenabled products that have the potential to realize a net environmental, health, or societal benefit.

  18. Integrated optic chemical sensor for the simultaneous detection and quantification of multiple ions. Final report, March--September 1995

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza, E.

    1995-09-01

    This final report summarizes the work performed by Physical Optics Corporation (POC) on the DOE contract entitled {open_quotes}Integrated Optic Chemical Sensor for the Simultaneous Detection and Quantification of Multiple Metal Ions{close_quotes}. This project successfully demonstrated a multi-element integrated optic chemical sensor (IOCS) system capable of simultaneous detection and quantification of metal ions in a water flow stream. POC`s innovative integrated optic chemical sensor technology uses an array of chemically active optical waveguides integrated in parallel in a single small IOCS chip. The IOCS technique uses commonly available materials and straightforward processing to produce channel waveguides in porous glass, each channel treated with a chemical indicator that responds optically to heavy metal ions in a water flow stream. The porosity of the glass allows metal ions present in the water to diffuse into the glass and interact with the immobilized indicators, producing a measurable optical chance. For the {open_quotes}proof-of-concept{close_quotes} demonstration, POC designed and fabricated two types of IOCS chips. Type I uses an array of four straight channel waveguides, three of which are doped with a metal sensitive indicator, an ionophore. The undoped fourth channel is used as the reference channel. Type II uses a 1 x 4 star coupler structure with three sensing channels and a reference channel. Successful implementation of the IOCS technology is expected to have a broad impact on water quality control as well as in the commercial environmental monitoring market. Because of the self-referenced, multidetection capability of the IOCS technique, POC`s water quality sensors are expected to find markets in environmental monitoring and protection, ground water monitoring, and in-line process control. Specific applications include monitoring of chromium, copper, and iron ions in water discharged by the metal plating industry.

  19. On the performance of surface plasmon resonance based fibre optic sensor with different bimetallic nanoparticle alloy combinations

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Anuj K; Mohr, Gerhard J [Institute of Physical Chemistry, Friedrich-Schiller University, Lessingstrasse 10, 07743 Jena (Germany)], E-mail: anuj.sharma@uni-jena.de

    2008-03-07

    In this work, we have investigated the capability of different bimetallic nanoparticle alloy combinations to be used in fibre optic sensors based on the technique of surface plasmon resonance. The metals considered for this analysis are silver, gold, copper and aluminium. The performance of the sensor with different bimetallic nanoparticle alloy combinations is evaluated and compared numerically. The performance is analysed in terms of three parameters: sensitivity, signal-to-noise ratio (SNR) and operating range for the sensing layer refractive index values. On the basis of the comparison and some logistic criteria, the best possible bimetallic alloy combinations along with a requisite alloy composition ratio are predicted. The bimetallic nanoparticle alloy combination is capable of simultaneously providing larger values of sensitivity, SNR and operating range, which is not possible with any single metallic nanoparticle layer.

  20. A practical application combining wireless sensor networks and Internet of Things: Safety Management System for Tower Crane Groups.

    Science.gov (United States)

    Zhong, Dexing; Lv, Hongqiang; Han, Jiuqiang; Wei, Quanrui

    2014-07-30

    The so-called Internet of Things (IoT) has attracted increasing attention in the field of computer and information science. In this paper, a specific application of IoT, named Safety Management System for Tower Crane Groups (SMS-TC), is proposed for use in the construction industry field. The operating status of each tower crane was detected by a set of customized sensors, including horizontal and vertical position sensors for the trolley, angle sensors for the jib and load, tilt and wind speed sensors for the tower body. The sensor data is collected and processed by the Tower Crane Safety Terminal Equipment (TC-STE) installed in the driver's operating room. Wireless communication between each TC-STE and the Local Monitoring Terminal (LMT) at the ground worksite were fulfilled through a Zigbee wireless network. LMT can share the status information of the whole group with each TC-STE, while the LMT records the real-time data and reports it to the Remote Supervision Platform (RSP) through General Packet Radio Service (GPRS). Based on the global status data of the whole group, an anti-collision algorithm was executed in each TC-STE to ensure the safety of each tower crane during construction. Remote supervision can be fulfilled using our client software installed on a personal computer (PC) or smartphone. SMS-TC could be considered as a promising practical application that combines a Wireless Sensor Network with the Internet of Things.

  1. A MEMS thermal shear stress sensor produced by a combination of substrate-free structures with anodic bonding technology

    Science.gov (United States)

    Ou, Yi; Qu, Furong; Wang, Guanya; Nie, Mengyan; Li, Zhigang; Ou, Wen; Xie, Changqing

    2016-07-01

    By combining substrate-free structures with anodic bonding technology, we present a simple and efficient micro-electro-mechanical system (MEMS) thermal shear stress sensor. Significantly, the resulting depth of the vacuum cavity of the sensor is determined by the thickness of the silicon substrate at which Si is removed by the anisotropic wet etching process. Compared with the sensor based on a sacrificial layer technique, the proposed MEMS thermal shear-stress sensor exhibits dramatically improved sensitivity due to the much larger vacuum cavity depth. The fabricated MEMS thermal shear-stress sensor with a vacuum cavity depth as large as 525 μm and a vacuum of 5 × 10-2 Pa exhibits a sensitivity of 184.5 mV/Pa and a response time of 180 μs. We also experimentally demonstrate that the sensor power is indeed proportional to the 1/3-power of the applied shear stress. The substrate-free structures offer the ability to precisely measure the shear stress fluctuations in low speed turbulent boundary layer wind tunnels.

  2. MOFs for the Sensitive Detection of Ammonia: Deployment of fcu-MOF Thin-Films as Effective Chemical Capacitive Sensors.

    KAUST Repository

    Assen, Ayalew Hussen

    2017-08-15

    This work reports on the fabrication and deployment of a select metal-organic framework (MOF) thin film as an advanced chemical capacitive sensor for the sensing/detection of ammonia (NH3) at room temperature. Namely, the MOF thin film sensing layer consists of a rare-earth (RE) MOF (RE-fcu-MOF) deposited on a capacitive interdigitated electrode (IDE). Purposely, the chemically stable naphthalene-based RE-fcu-MOF (NDC-Y-fcu-MOF) was elected and prepared/arranged as a thin film on a pre-functionalized capacitive IDE via the solvothermal growth method. Unlike earlier realizations, the fabricated MOF-based sensor showed a notable detection sensitivity for NH3 at concentrations down to 1 ppm, with a detection limit appraised to be around 100 ppb (at room temperature) even in the presence of humidity and/or CO2. Distinctly, the NDC-Y-fcu-MOF based sensor exhibited the required stability to NH3, in contract to other reported MOFs, and a remarkable detection selectivity towards NH3 vs. CH4, NO2, H2 and C7H8. The NDC-Y-fcu-MOF based sensor exhibited excellent performance for sensing ammonia for simulated breathing system in the presence of the mixture of carbon dioxide and/or humidity (water vapor), with no major alteration in the detection signal.

  3. MOFs for the Sensitive Detection of Ammonia: Deployment of fcu-MOF Thin Films as Effective Chemical Capacitive Sensors.

    Science.gov (United States)

    Assen, Ayalew H; Yassine, Omar; Shekhah, Osama; Eddaoudi, Mohamed; Salama, Khaled N

    2017-09-22

    This work reports on the fabrication and deployment of a select metal-organic framework (MOF) thin film as an advanced chemical capacitive sensor for the sensing/detection of ammonia (NH3) at room temperature. Namely, the MOF thin film sensing layer consists of a rare-earth (RE) MOF (RE-fcu-MOF) deposited on a capacitive interdigitated electrode (IDE). Purposely, the chemically stable naphthalene-based RE-fcu-MOF (NDC-Y-fcu-MOF) was elected and prepared/arranged as a thin film on a prefunctionalized capacitive IDE via the solvothermal growth method. Unlike earlier realizations, the fabricated MOF-based sensor showed a notable detection sensitivity for NH3 at concentrations down to 1 ppm, with a detection limit appraised to be around 100 ppb (at room temperature) even in the presence of humidity and/or CO2. Distinctly, the NDC-Y-fcu-MOF based sensor exhibited the required stability to NH3, in contrast to other reported MOFs, and a remarkable detection selectivity toward NH3 vs CH4, NO2, H2, and C7H8. The NDC-Y-fcu-MOF based sensor exhibited excellent performance for sensing ammonia for simulated breathing system in the presence of the mixture of carbon dioxide and/or humidity (water vapor), with no major alteration in the detection signal.

  4. Adaptive Cooperative FEC Based on Combination of Network Coding and Channel Coding for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Yong Jin

    2014-02-01

    Full Text Available The data delivery over wireless links with QoS-guarantee is a big challenge because of the unreliable and dynamic characteristics of wireless sensor networks, as well as QoS diversity requirements of applications. In this paper, we propose an adaptive cooperative Forward Error Correction algorithm based on network coding, in the hope quality of experience could be satisfied on receivers with high quality. The algorithm, based on wireless link and distance, adjusts the RS coder parameter and selects the optimal relay nodes. On the other hand, we combine the channel coding and network coding technology at the data link layer to fulfil the requirements of QoS diversity. Both mathematical analysis and NS simulation results demonstrate the proposed mechanism is superior to the traditional FEC and cooperative FEC alone at the reliability, real time performance and energy efficiency. In addition, the proposed mechanism can significantly improve quality of media streaming, in terms of playable frame rate on the receiving side. 

  5. A Positioning Scheme Combining Location Tracking with Vision Assisting for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    F. Tsai1,

    2013-03-01

    Full Text Available This paper presents the performance of an adaptive location-estimation technique combining Kalman filtering (KFwith vision assisting for wireless sensor networks. For improving the accuracy of a location estimator, a KF procedureis employed at a mobile terminal to filter variations of the location estimate. Furthermore, using a vision-assistedcalibration technique, the proposed approach based on the normalized cross-correlation scheme is an accuracyenhancement procedure that effectively removes system errors causing uncertainty in real dynamic environments.Namely, according to the vision-assisted approach to extract the locations of the reference nodes as landmarks, a KFbasedapproach with the landmark information can calibrate the location estimation and reduce the corner effect of alocation-estimation system. In terms of the location accuracy estimated from the proposed approach, the experimentalresults demonstrate that more than 60 percent of the location estimates have error distances less than 1.4 meters in aZigBee positioning platform. As compared with the non-tracking algorithm and non-vision-assisted approach, theproposed algorithm can achieve reasonably good performance.

  6. A Lightweight Encryption Scheme Combined with Trust Management for Privacy-Preserving in Body Sensor Networks.

    Science.gov (United States)

    Guo, Ping; Wang, Jin; Ji, Sai; Geng, Xue Hua; Xiong, Neal N

    2015-12-01

    With the pervasiveness of smart phones and the advance of wireless body sensor network (BSN), mobile Healthcare (m-Healthcare), which extends the operation of Healthcare provider into a pervasive environment for better health monitoring, has attracted considerable interest recently. However, the flourish of m-Healthcare still faces many challenges including information security and privacy preservation. In this paper, we propose a secure and privacy-preserving framework combining with multilevel trust management. In our scheme, smart phone resources including computing power and energy can be opportunistically gathered to process the computing-intensive PHI (personal health information) during m-Healthcare emergency with minimal privacy disclosure. In specific, to leverage the PHI privacy disclosure and the high reliability of PHI process and transmission in m-Healthcare emergency, we introduce an efficient lightweight encryption for those users whose trust level is low, which is based on mix cipher algorithms and pair of plain text and cipher texts, and allow a medical user to decide who can participate in the opportunistic computing to assist in processing his overwhelming PHI data. Detailed security analysis and simulations show that the proposed framework can efficiently achieve user-centric privacy protection in m-Healthcare system.

  7. Ultrasensitive and selective 4-aminophenol chemical sensor development based on nickel oxide nanoparticles decorated carbon nanotube nanocomposites for green environment.

    Science.gov (United States)

    Hussain, Mohammad Musarraf; Rahman, Mohammed M; Asiri, Abdullah M

    2017-03-01

    Nickel oxide nanoparticles decorated carbon nanotube nanocomposites (NiO·CNT NCs) were prepared in a basic medium by using facile wet-chemical routes. The optical, morphological, and structural properties of NiO·CNT NCs were characterized using Fourier transformed infra-red (FT-IR), Ultra-violet visible (UV/Vis) spectroscopy, field-emission scanning electron microscopy (FESEM), X-ray energy dispersed spectroscopy (XEDS), X-ray photoelectron spectroscopy (XPS), and powder X-ray diffraction (XRD) methods. Selective 4-aminophenol (4-AP) chemical sensor was developed by a flat glassy carbon electrode (GCE, surface area: 0.0316cm(2)) fabricated with a thin-layer of NCs. Electrochemical responses including higher sensitivity, large dynamic range (LDR), limit of detection (LOD), and long-term stability towards 4-AP were obtained using the fabricated chemical sensors. The calibration curve was found linear (R(2)=0.914) over a wide range of 4-AP concentration (0.1nmol/L-0.1mol/L). In perspective of slope (2×10(-5)μA/μM), LOD and sensitivity were calculated as 15.0±0.1pM and ~6.33×10(-4)μA/(μM·cm) respectively. The synthesized NiO·CNT NCs using a wet-chemical method is a significant route for the development of ultrasensitive and selective phenolic sensor based on nano-materials for environmental toxic substances. It is suggested that a pioneer and selective development of 4-AP sensitive sensor using NiO·CNT NCs by a facile and reliable current vs voltage (I-V) method for the major application of toxic agents in biological, green environmental, and health-care fields in near future. Copyright © 2016. Published by Elsevier B.V.

  8. Nanostructured Fiber Optic Cantilever Arrays and Hybrid MEMS Sensors for Chemical and Biological Detection Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Advancements in nano-/micro-scale sensor fabrication and molecular recognition surfaces offer promising opportunities to develop miniaturized hybrid fiber optic and...

  9. Metal oxide nanostructures synthesized on flexible and solid substrates and used for catalysts, UV detectors, and chemical sensors

    Science.gov (United States)

    Willander, Magnus; Sadollahkhani, Azar; Echresh, Ahmad; Nur, Omer

    2014-03-01

    In this paper we demonstrate the visibility of the low temperature chemical synthesis for developing device quality material grown on flexible and solid substrates. Both colorimetric sensors and UV photodetectors will be presented. The colorimetric sensors developed on paper were demonstrated for heavy metal detection, in particular for detecting copper ions in aqueous solutions. The demonstrated colorimetric copper ion sensors developed here are based on ZnO@ZnS core-shell nanoparticles (CSNPs). These sensors demonstrated an excellent low detection limit of less than 1 ppm of copper ions. Further the colorimetric sensors operate efficiently in a wide pH range between 4 and 11, and even in turbulent water. The CSNPs were additionally used as efficient photocatalytic degradation element and were found to be more efficient than pure ZnO nanoparticles (NPs). Also p-NiO/n-ZnO thin film/nanorods pn junctions were synthesized by a two-step synthesis process and were found to act as efficient UV photodetectors. Additionally we show the effect of the morphology of different CuO nanostructures on the efficiency of photo catalytic degradation of Congo red organic dye.

  10. Path to Impact for Autonomous Field Deployable Chemical Sensors: A Case Study of in Situ Nitrite Sensors.

    Science.gov (United States)

    Schierenbeck, Tim M; Smith, Matthew C

    2017-04-11

    Natural freshwater systems have been severely affected by excess loading of macronutrients (e.g., nitrogen and phosphorus) from fertilizers, fossil fuels, and human and livestock waste. In the USA, impacts to drinking water quality, biogeochemical cycles, and aquatic ecosystems are estimated to cost US$210 billion annually. Field-deployable nutrient sensors (FDS) offer potential to support research and resource management efforts by acquiring higher resolution data than are currently supported by expensive conventional sampling methods. Following nearly 40 years of research and development, FDS instruments are now starting to penetrate commercial markets. However, instrument uncertainty factors (high cost, reliability, accuracy, and precision) are key drivers impeding the uptake of FDS by the majority of users. Using nitrite sensors as a case study, we review the trends, opportunities, and challenges in producing and implementing FDS from a perspective of innovation and impact. We characterize the user community and consumer needs, identify trends in research approaches, tabulate state-of-the-art examples and specifications, and discuss data life cycle considerations. With further development of FDS through prototyping and testing in real-world applications, these tools can deliver information for protecting and restoring natural waters, enhancing process control for industrial operations and water treatment, and providing novel research insights.

  11. Testing a combined radiation protection modality: chemical protector and local shielding.

    Science.gov (United States)

    Minkova, M; Baldzhijska, M

    1989-01-01

    The impact of combined radiation protection upon damage to critical organs-spleen, small intestine, and bone marrow was studied in adult rat males 3 days after whole-body exposure to 9.5 Gy gamma-ray dose. Adeturone, the chemical radioprotector used, was administered intraperitoneally at 1/17 of its LD50 dose. Local shielding of the abdomino-lumbal region was accomplished using a lead ring providing on average 28-30% attenuation of radiation exposure. This degree of physical abdomino-lumbal protection combined with adeturone (50 mg/kg) pretreatment resulted in mutual enhancement of the components' action, expansion of the chemical agent's therapeutic range, providing a combination with improved overall antiradiation properties.

  12. Let's get Physiqual - An intuitive and generic method to combine sensor technology with ecological momentary assessments

    NARCIS (Netherlands)

    Blaauw, F J; Schenk, H M; Jeronimus, B F; van der Krieke, L.; de Jonge, P; Aiello, M; Emerencia, A C

    2016-01-01

    The emergence of wearables and smartwatches is making sensors a ubiquitous technology to measure daily rhythms in physiological measures, such as movement and heart rate. An integration of sensor data from wearables and self-report questionnaire data about cognition, behaviors, and emotions can prov

  13. Low power silicon-based thermal sensors and actuators for chemical applications

    NARCIS (Netherlands)

    Vereshchagina, Elizaveta

    2011-01-01

    In the Hot Silicon project low and ultra-low-power Si-based hot surface devices have been developed, i.e. thermal sensors and actuators, for application in catalytic gas micro sensors, micro- and nano- calorimeters. This work include several scientific and technological aspects: • Design and fabrica

  14. Cantilever-based bio-chemical sensor integrated in a microliquid handling system

    DEFF Research Database (Denmark)

    Thaysen, Jacob; Marie, Rodolphe; Boisen, Anja

    2001-01-01

    The cantilevers have integrated piezoresistive readout which, compared to optical readout, enables simple measurements on even non-transparent liquids, such as blood. First, we introduce a simple theory for using piezoresistive cantilevers as surface stress sensors. Then, the sensor fabrication b...

  15. Thermal and chemical treatment of polymer optical fiber Bragg grating sensors for enhanced mechanical sensitivity

    DEFF Research Database (Denmark)

    Pospori, Andreas; Marques, C. A. F.; Saez-Rodriguez, D.

    2017-01-01

    An investigation of the thermal annealing effects on the strain, stress, and force sensitivities of polymer optical fiber Bragg grating sensors is performed. We demonstrate for the first time that the fiber annealing can enhance both stress and force sensitivities of Bragg grating sensors, with t...

  16. Study of Halitosis-Substance Sensing at Low Concentration Using an Electrochemical Sensor Array Combined with a Preconcentrator

    Science.gov (United States)

    Sasaya, Yosuke; Nakamoto, Takamichi

    A method for quantitative detection and discrimination of volatile sulfur compounds (VSCs) using an electrochemical sensor array combined with a preconcentrator was proposed. Halitosis is due to VSCs produced by bacterial metabolism inside the oral cavity. An organoleptic test is typically performed by a dental clinician for the assessment of halitosis, although it is a subjective test. Thus, an objective evaluation of halitosis is required. In this study, it was possible to discriminate among the VSCs such as hydrogen sulfide (H2S), methyl mercaptan (CH3SH), and dimethyl sulfide ((CH3)2S) over the range of 200ppb to 1000ppb. Moreover, mixture of two VSC vapors (H2S and CH3SH) at various mixing ratios were measured. The results indicated that the sensor responses to mixed samples satisfied the linear superposition. The mixture compositions of VSCs were almost correctly obtained from the sensor responses using partial least squares (PLS) regression analysis.

  17. The performance of a piezoelectric-sensor-based SHM system under a combined cryogenic temperature and vibration environment

    Science.gov (United States)

    Qing, Xinlin P.; Beard, Shawn J.; Kumar, Amrita; Sullivan, Kevin; Aguilar, Robert; Merchant, Munir; Taniguchi, Mike

    2008-10-01

    A series of tests have been conducted to determine the survivability and functionality of a piezoelectric-sensor-based active structural health monitoring (SHM) SMART Tape system under the operating conditions of typical liquid rocket engines such as cryogenic temperature and vibration loads. The performance of different piezoelectric sensors and a low temperature adhesive under cryogenic temperature was first investigated. The active SHM system for liquid rocket engines was exposed to flight vibration and shock environments on a simulated large booster LOX-H2 engine propellant duct conditioned to cryogenic temperatures to evaluate the physical robustness of the built-in sensor network as well as operational survivability and functionality. Test results demonstrated that the developed SMART Tape system can withstand operational levels of vibration and shock energy on a representative rocket engine duct assembly, and is functional under the combined cryogenic temperature and vibration environment.

  18. Prediction of Effective Drug Combinations by Chemical Interaction, Protein Interaction and Target Enrichment of KEGG Pathways

    Directory of Open Access Journals (Sweden)

    Lei Chen

    2013-01-01

    Full Text Available Drug combinatorial therapy could be more effective in treating some complex diseases than single agents due to better efficacy and reduced side effects. Although some drug combinations are being used, their underlying molecular mechanisms are still poorly understood. Therefore, it is of great interest to deduce a novel drug combination by their molecular mechanisms in a robust and rigorous way. This paper attempts to predict effective drug combinations by a combined consideration of: (1 chemical interaction between drugs, (2 protein interactions between drugs’ targets, and (3 target enrichment of KEGG pathways. A benchmark dataset was constructed, consisting of 121 confirmed effective combinations and 605 random combinations. Each drug combination was represented by 465 features derived from the aforementioned three properties. Some feature selection techniques, including Minimum Redundancy Maximum Relevance and Incremental Feature Selection, were adopted to extract the key features. Random forest model was built with its performance evaluated by 5-fold cross-validation. As a result, 55 key features providing the best prediction result were selected. These important features may help to gain insights into the mechanisms of drug combinations, and the proposed prediction model could become a useful tool for screening possible drug combinations.

  19. Use of a combined SpO₂/PtcCO₂ sensor in the delivery room.

    Science.gov (United States)

    Rubortone, Serena Antonia; De Carolis, Maria Pia; Lacerenza, Serafina; Bersani, Iliana; Occhipinti, Federica; Romagnoli, Costantino

    2012-01-01

    Arterial oxygen saturation (SaO(2)) and partial arterial pressure of carbon dioxide (PaCO(2)) are important respiratory parameters in critically ill neonates. A sensor combining a pulse oximeter with the Stow-Severinghaus electrode, required for the measurement of peripheral oxygen saturation (SpO(2)) and transcutaneous partial pressure of carbon dioxide (PtcCO(2)), respectively, has been recently used in neonatal clinical practice (TOSCA(500Ò)Radiometer). We evaluated TOSCA usability and reliability in the delivery room (DR), throughout three different periods, on term, late-preterm, and preterm neonates. During the first period (period A), 30 healthy term neonates were simultaneously monitored with both TOSCA and a MASIMO pulse oximeter. During the second period (period B), 10 healthy late-preterm neonates were monitored with both TOSCA and a transcutaneous device measuring PtcCO(2) (TINA(Ò) TCM3, Radiometer). During the third period (period C), 15 preterm neonates were monitored with TOSCA and MASIMO after birth, during stabilization, and during transport to the neonatal intensive care unit (NICU). Blood gas analyses were performed to compare transcutaneous and blood gas values. TOSCA resulted easily and safely usable in the DR, allowing reliable noninvasive SaO(2) estimation. Since PtcCO(2) measurements with TOSCA required at least 10 min to be stable and reliable, this parameter was not useful during the early resuscitation immediately after birth. Moreover, PtcCO(2) levels were less precise if compared to the conventional transcutaneous monitoring. However, PtcCO(2) measurement by TOSCA was useful as trend-monitoring after stabilization and during transport to NICU.

  20. Theoretical investigation of conductivity sensitivities of SiC-based bio-chemical acoustic wave sensors

    Science.gov (United States)

    Fan, Li; Chen, Zhe; Zhang, Shu-yi; Zhang, Hui

    2014-02-01

    The phase velocities, electromechanical coupling coefficients, conductivity sensitivities, insert losses, and minimum detectable masses of Rayleigh and Lamb waves sensors based on silicon carbide (SiC) substrates are theoretically studied. The results are compared with the performances of the sensors based on conventional silicon substrates. It is found that the sensors using SiC substrates have higher electromechanical coupling coefficients and conductivity sensitivities than the conventional silicon-based sensors in virtue of piezoelectricity of the SiC. Moreover, higher phase velocities in SiC substrates can reduce the insert losses and minimum detectable masses of the sensors. In this case, in the detection of the gas with the tiny mass as the hydrogen, in which the conductivity sensitivity is more important than the mass sensitivity, the sensor based on the SiC substrate has a higher sensitivity and exhibits the potential to detect the gas with the concentration below the ppm level. According to the results, the performances of the sensors based on the Rayleigh and Lamb waves using the SiC substrates can be optimized by properly selecting piezoelectric films, structural parameters, and operating wavelengths.

  1. Nuclear, biological, and chemical combined injuries and countermeasures on the battlefield.

    Science.gov (United States)

    Knudson, Gregory B; Elliott, Thomas B; Brook, Itzhak; Shoemaker, Michael O; Pastel, Ross H; Lowy, Robert J; King, Gregory L; Herzig, Thomas C; Landauer, Michael R; Wilson, Scott A; Peacock, Susan J; Bouhaouala, S Samy; Jackson, William E; Ledney, G David

    2002-02-01

    The Armed Forces Radiobiological Research Institute (AFRRI) has developed a research program to determine the major health risks from exposure to ionizing radiation in combination with biological and chemical warfare agents and to assess the extent to which exposure to ionizing radiation compromises the effectiveness of protective drugs, vaccines, and other biological and chemical warfare prophylactic and treatment strategies. AFRRI's Defense Technology Objective MD22 supports the development of treatment modalities and studies to assess the mortality rates for combined injuries from exposure to ionizing radiation and Bacillus anthracis, and research to provide data for casualty prediction models that assess the health consequences of combined exposures. In conjunction with the Defense Threat Reduction Agency, our research data are contributing to the development of casualty prediction models that estimate mortality and incapacitation in an environment of radiation exposure plus other weapons of mass destruction. Specifically, the AFFRI research program assesses the effects of ionizing radiation exposure in combination with B. anthracis, Venezuelan equine encephalomyelitis virus, Shigella sonnei, nerve agents, and mustard as well as their associated treatments and vaccines. In addition, the long-term psychological effects of radiation combined with nuclear, biological, and chemical (NBC) injuries are being evaluated. We are also assessing the effectiveness of gamma photons and high-speed neutrons and electrons for neutralizing biological and chemical warfare agents. New protocols based on our NBC bioeffects experiments will enable U.S. armed forces to accomplish military operations in NBC environments while optimizing both survival and military performance. Preserving combatants' health in an NBC environment will improve warfighting operations and mission capabilities.

  2. Real-time, wide-area hyperspectral imaging sensors for standoff detection of explosives and chemical warfare agents

    Science.gov (United States)

    Gomer, Nathaniel R.; Tazik, Shawna; Gardner, Charles W.; Nelson, Matthew P.

    2017-05-01

    Hyperspectral imaging (HSI) is a valuable tool for the detection and analysis of targets located within complex backgrounds. HSI can detect threat materials on environmental surfaces, where the concentration of the target of interest is often very low and is typically found within complex scenery. Unfortunately, current generation HSI systems have size, weight, and power limitations that prohibit their use for field-portable and/or real-time applications. Current generation systems commonly provide an inefficient area search rate, require close proximity to the target for screening, and/or are not capable of making real-time measurements. ChemImage Sensor Systems (CISS) is developing a variety of real-time, wide-field hyperspectral imaging systems that utilize shortwave infrared (SWIR) absorption and Raman spectroscopy. SWIR HSI sensors provide wide-area imagery with at or near real time detection speeds. Raman HSI sensors are being developed to overcome two obstacles present in standard Raman detection systems: slow area search rate (due to small laser spot sizes) and lack of eye-safety. SWIR HSI sensors have been integrated into mobile, robot based platforms and handheld variants for the detection of explosives and chemical warfare agents (CWAs). In addition, the fusion of these two technologies into a single system has shown the feasibility of using both techniques concurrently to provide higher probability of detection and lower false alarm rates. This paper will provide background on Raman and SWIR HSI, discuss the applications for these techniques, and provide an overview of novel CISS HSI sensors focusing on sensor design and detection results.

  3. Combined Simulation of a Micro Permanent Magnetic Linear Contactless Displacement Sensor

    Directory of Open Access Journals (Sweden)

    Jing Gao

    2010-09-01

    Full Text Available The permanent magnetic linear contactless displacement (PLCD sensor is a new type of displacement sensor operating on the magnetic inductive principle. It has many excellent properties and has already been used for many applications. In this article a Micro-PLCD sensor which can be used for microelectromechanical system (MEMS measurements is designed and simulated with the CST EM STUDIO® software, including building a virtual model, magnetostatic calculations, low frequency calculations, steady current calculations and thermal calculations. The influence of some important parameters such as air gap dimension, working frequency, coil current and eddy currents etc. is studied in depth.

  4. Combined simulation of a micro permanent magnetic linear contactless displacement sensor.

    Science.gov (United States)

    Gao, Jing; Müller, Wolfgang F O; Greiner, Felix; Eicher, Dirk; Weiland, Thomas; Schlaak, Helmut F

    2010-01-01

    The permanent magnetic linear contactless displacement (PLCD) sensor is a new type of displacement sensor operating on the magnetic inductive principle. It has many excellent properties and has already been used for many applications. In this article a Micro-PLCD sensor which can be used for microelectromechanical system (MEMS) measurements is designed and simulated with the CST EM STUDIO(®) software, including building a virtual model, magnetostatic calculations, low frequency calculations, steady current calculations and thermal calculations. The influence of some important parameters such as air gap dimension, working frequency, coil current and eddy currents etc. is studied in depth.

  5. Opto-chemical sensors based on integrated ring-shaped organic photodiodes: progress and applications

    Science.gov (United States)

    Mayr, Torsten; Abel, Tobias; Ungerböck, Birgit; Sagmeister, Martin; Charwat, Verena; Ertl, Peter; Kraker, Elke; Köstler, Stefan; Tschepp, Andreas; Lamprecht, Bernhard

    2012-10-01

    The recent advances on a monolithically integrated sensor platform based on ring-shaped organic photo detectors are presented. Various sensing chemistries based on luminescence for the detection of a number of parameters such as oxygen, carbon dioxide, humidity and pH in gaseous and/or liquid phase were investigated and optimized to the requirements of the sensor platform. Aiming on practical application, the need and methods to reference luminescence signals are evaluated including two wavelength rationing and lifetime measurements. Finally, we will discuss potential applications of the platform and present a micro-fluidic chip containing an array of integrated sensor spots and organic photodiodes.

  6. Sol-gels with fiber-optic chemical sensor potential: Effects of preparation, aging, and long-term storage

    Science.gov (United States)

    Badini, G. E.; Grattan, K. T. V.; Tseung, A. C. C.

    1995-08-01

    The features of sol-gels, incorporating pH-sensitive dyes, designed as potential substrates for fiber-optic chemical sensors, have been investigated in terms of a variety of characteristics resulting from the preparation methods used and following the storage of samples for a period of several years. These materials, organically doped sol-gels, have been used as the heart of a number of prototype chemical sensing instruments, and a key issue in their effective use in instrumentation is their long-term durability and stability. In this work, it has been shown that such aged gel substrates can withstand immersion in water, drying, and reimmersion without fragmenting. Such impregnated gels were shown to still exhibit strong fluorescence, although some changes to the gel structure, determined from microhardness measurements, were observed and reported, reflecting their potential for use in chemically sensitive fiber optic-based instruments.

  7. Wireless fiber laser sensor combining photonic generation beat frequency demodulation technology

    Science.gov (United States)

    Liu, Shengchun; Gu, Rong; Yu, Xiujuan; Yin, Zuowei; Chen, Xiangfei

    2011-12-01

    A simple wireless-fiber laser sensor is proposed base on directly photonic generation of microwave beat signal. In this scheme, a multi-longitudinal modes fiber laser is formed by two fiber Bragg gratings and a section of erbium-doped fiber. Two same 2G-GSM mobile antennas are used as wireless transmitter and receiver. By this method, the real-time monitoring of fiber laser sensors can be achieved through over ultra-long distance. This technique offers a simple, all-electrical and cheap way for fiber sensor information accessing wireless net. The experiment result shows the root mean square deviations of the sensor are about 4.7 μɛ and 6.7 μɛ at 2.38 GHz before and after wireless transmission, respectively.

  8. Optimal fractionation and bioassay plans for isolation of synergistic chemicals: The subtractive-combination method.

    Science.gov (United States)

    Byers, J A

    1992-09-01

    Studies of chemical ecology of an organism are founded on the isolation and identification of a semiochemical, often comprised of two or more synergistic compounds (each Synergist alone has little activity, but presented together they are bioactive). Chromatographie fractionation and bioassay methods of binary splitting, additive combination, and subtractive combination are compared for efficiency in isolating synergists. Formulas are derived for the latter two methods that calculate the expected number of bioassay tests required for isolation of from two to five synergists from biological extracts with any number of compounds, depending on the number of initial (major) Chromatographic fractions. A computer program based on the formulas demonstrates the superiority of the subtractive-combination method. Simulations with the program were used to determine the optimal number of initial fractions for the additive- and subtractive-combination methods when isolating two to five synergists from extracts of from 25 to 1200 compounds. Methods of bioassay, isolation, identification, and field testing of semiochemicals are discussed.

  9. The comparison of removing plug by ultrasonic wave, chemical deplugging agent and ultrasound-chemical combination deplugging for near-well ultrasonic processing technology.

    Science.gov (United States)

    Wang, Zhenjun; Xu, Yuanming; Bajracharya, Suman

    2015-11-01

    Near-well ultrasonic processing technology is characterized by high adaptability, simple operation, low cost and zero pollution. The main plugs of oil production include paraffin deposition plug, polymer plug, and drilling fluid plug etc. Although some good results have been obtained through laboratory experiments and field tests, systematic and intensive studies are absent for certain major aspects, such as: effects of ultrasonic treatment for different kinds of plugs and whether effect of ultrasound-chemicals combination deplugging is better than that of ultrasonic deplugging. In this paper, the experiments of removing drilling fluid plug, paraffin deposition plug and polymer plug by ultrasonic wave, chemical deplugging agent and ultrasound-chemical combination deplugging respectively are carried out. Results show that the effect of ultrasound-chemical combination deplugging is clearly better than that of using ultrasonic wave and chemical deplugging agent separately, which indicates that ultrasonic deplugging and chemical deplugging can produce synergetic effects. On the one hand, ultrasonic treatment can boost the activity of chemical deplugging agent and turn chemical deplugging into dynamic chemical process, promoting chemical agent reaction speed and enhancing deplugging effect; on the other hand, chemical agent can reduce the adhesion strength of plugs so that ultrasonic deplugging effect can be improved significantly. Experimental results provide important reference for near-well ultrasonic processing technology.

  10. Diesel combustion: an integrated view combining laser diagnostics, chemical kinetics, and empirical validation

    Energy Technology Data Exchange (ETDEWEB)

    Akinyami, O C; Dec, J E; Durrett, R P; Flynn, P F; Hunter, G L; Loye, A O; Westbrook, C

    1999-02-01

    This paper proposes a structure for the diesel combustion process based on a combination of previously published and new results. Processes are analyzed with proven chemical kinetic models and validated with data from production-like direct injection diesel engines. The analysis provides new insight into the ignition and particulate formation processes, which combined with laser diagnostics, delineates the two-stage nature of combustion in diesel engines. Data are presented to quantify events occurring during the ignition and initial combustion processes that form soot precursors. A framework is also proposed for understanding the heat release and emission formation processes.

  11. Intrinsic Fiber Optic Chemical Sensors for Subsurface Detection of CO2

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Jesus [Intelligent Optical Systems, Inc., Torrance, CA (United States)

    2016-01-01

    Intelligent Optical Systems, Inc. has developed distributed intrinsic fiber optic sensors to directly quantify the concentration of dissolved or gas-phase CO2 for leak detection or plume migration in carbon capture and sequestration (CCS). The capability of the sensor for highly sensitive detection of CO2 in the pressure and temperature range of 15 to 2,000 psi and 25°C to 175°C was demonstrated, as was the capability of operating in highly corrosive and contaminated environments such as those often found in CO2 injection sites. The novel sensor system was for the first time demonstrated deployed in a deep well, detecting multiple CO2 releases, in real time, at varying depths. Early CO2 release detection, by means of a sensor cable integrating multiple sensor segments, was demonstrated, as was the capability of quantifying the leak. The novel fiber optic sensor system exhibits capabilities not achieved by any other monitoring technology. This project represents a breakthrough in monitoring capabilities for CCS applications.

  12. Chemical entity recognition in patents by combining dictionary-based and statistical approaches.

    Science.gov (United States)

    Akhondi, Saber A; Pons, Ewoud; Afzal, Zubair; van Haagen, Herman; Becker, Benedikt F H; Hettne, Kristina M; van Mulligen, Erik M; Kors, Jan A

    2016-01-01

    We describe the development of a chemical entity recognition system and its application in the CHEMDNER-patent track of BioCreative 2015. This community challenge includes a Chemical Entity Mention in Patents (CEMP) recognition task and a Chemical Passage Detection (CPD) classification task. We addressed both tasks by an ensemble system that combines a dictionary-based approach with a statistical one. For this purpose the performance of several lexical resources was assessed using Peregrine, our open-source indexing engine. We combined our dictionary-based results on the patent corpus with the results of tmChem, a chemical recognizer using a conditional random field classifier. To improve the performance of tmChem, we utilized three additional features, viz. part-of-speech tags, lemmas and word-vector clusters. When evaluated on the training data, our final system obtained an F-score of 85.21% for the CEMP task, and an accuracy of 91.53% for the CPD task. On the test set, the best system ranked sixth among 21 teams for CEMP with an F-score of 86.82%, and second among nine teams for CPD with an accuracy of 94.23%. The differences in performance between the best ensemble system and the statistical system separately were small.Database URL: http://biosemantics.org/chemdner-patents.

  13. Optical fiber chemical sensors with sol-gel derived nanomaterials for monitoring high temperature/high pressure reactions in clean energy technologies

    Science.gov (United States)

    Tao, Shiquan

    2010-04-01

    The development of sensor technologies for in situ, real time monitoring the high temperature/high pressure (HTP) chemical processes used in clean energy technologies is a tough challenge, due to the HTP, high dust and corrosive chemical environment of the reaction systems. A silica optical fiber is corrosive resistance, and can work in HTP conditions. This paper presents our effort in developing fiber optic sensors for in situ, real time monitoring the concentration of trace ammonia and hydrogen in high temperature gas samples. Preliminary test results illustrate the feasibility of using fiber optic sensor technologies for monitoring HTP processes for next generation energy industry.

  14. Synthesis and Characterization of Mimosa Pudica Leaves Shaped α-Iron Oxide Nanostructures for Ethanol Chemical Sensor Applications.

    Science.gov (United States)

    Kim, S H; Ibrahim, Ahmed A; Kumar, R; Umar, Ahmad; Abaker, M; Hwang, S W; Baskoutas, S

    2016-03-01

    Herein, the synthesis of mimosa pudica leaves shaped a-iron oxide (α-Fe2O3) nanostructures is reported through simple and facile hydrothermal process. The prepared α-Fe2O3 nanostructures were characterized in terms of their morphological, structural, compositional and optical properties through a variety of characterization techniques such as FESEM, EDS, XRD, FTIR and Raman spectroscopy. The detailed characterizations revealed the well-crystallinity and dense growth of mimosa pudica leaf shaped α-Fe2O3 nanostructures. Further, the prepared nanomaterials were used as efficient electron mediator to fabricate sensitive ethanol chemical sensor. The fabricated sensor exhibited a high sensitivity of -30.37 μAmM(-1) cm(-2) and low detection limit of -0.62 μM. The observed linear dynamic range (LDR) was in the range from 10 μM-0.625 μM.

  15. The Chemopreventive Effect of Tamoxifen Combined with Celecoxib on DMBA chemically-Induced Breast Cancer

    Institute of Scientific and Technical Information of China (English)

    Xiaoxu Liu; Huafeng Kang; Xijing Wang; Zhijun Dai; Fengjie Xue; Xinghuan Xue

    2007-01-01

    Objective: To investigate the chemopreventive effect of tamoxifen combined with a COX-2 selective inhibitor, celecoxib, on breast cancer in rats chemically induced by 7,12-dimethylben (a)anthracene (DMBA). Methods:DMBA was irrigated into the stomaches of SD female rats to build breast cancer model. A total of 120 rats were divided into four groups: control group, tamoxifen group, celecoxib group and combined group. The incidence rate, latent period, number and volume of breast cancer were detected and analyzed. Results:The tumor incidence rate of tamoxifen group (48.15%, 13/27) and celecoxib group (50.00%,14/28) were lower than that of control group (85.71%, 24/28), but higher than that of combined group (21.43%, 6/28). The tumor's latent period of tamoxifen group (97.54±1.85 d) and celecoxib group (96.79±2.89 d) were longer than that of control group (89.50±5.99 d), but shorter than that of combined group (103.67±3.39 d). The average tumor number of tamoxifen group (1.77±0.73) and celecoxib group (1.71±0.61) were less than that of control group (3.50±1.62), but more than that of combined group ( 1.17±0.42 ). The average tumor volume of tamoxifen group (1.78±0.71 cm3) and celecoxib group (2.05±1.04 cm3) were smaller than that of control group (6.42±3.96 cm3), but bigger than that of combined group (0.71±0.96 cm3) (P < 0.05 respectively).Conclusion:Celecoxib and tamoxifen are effective drugs in preventing the occurrence of rat breast cancer chemically induced by DMBA. Furthermore, combination of them has better chemopreventive effect.

  16. Mathematical Characterization of Protein Sequences Using Patterns as Chemical Group Combinations of Amino Acids

    Science.gov (United States)

    Choudhury, Pabitra Pal; Jana, Siddhartha Sankar

    2016-01-01

    Comparison of amino acid sequence similarity is the fundamental concept behind the protein phylogenetic tree formation. By virtue of this method, we can explain the evolutionary relationships, but further explanations are not possible unless sequences are studied through the chemical nature of individual amino acids. Here we develop a new methodology to characterize the protein sequences on the basis of the chemical nature of the amino acids. We design various algorithms for studying the variation of chemical group transitions and various chemical group combinations as patterns in the protein sequences. The amino acid sequence of conventional myosin II head domain of 14 family members are taken to illustrate this new approach. We find two blocks of maximum length 6 aa as ‘FPKATD’ and ‘Y/FTNEKL’ without repeating the same chemical nature and one block of maximum length 20 aa with the repetition of chemical nature which are common among all 14 members. We also check commonality with another motor protein sub-family kinesin, KIF1A. Based on our analysis we find a common block of length 8 aa both in myosin II and KIF1A. This motif is located in the neck linker region which could be responsible for the generation of mechanical force, enabling us to find the unique blocks which remain chemically conserved across the family. We also validate our methodology with different protein families such as MYOI, Myosin light chain kinase (MLCK) and Rho-associated protein kinase (ROCK), Na+/K+-ATPase and Ca2+-ATPase. Altogether, our studies provide a new methodology for investigating the conserved amino acids’ pattern in different proteins. PMID:27930687

  17. Identifying Rhodamine Dye Plume Sources in Near-Shore Oceanic Environments by Integration of Chemical and Visual Sensors

    Directory of Open Access Journals (Sweden)

    Jiangchen Yu

    2013-03-01

    Full Text Available This article presents a strategy for identifying the source location of a chemical plume in near-shore oceanic environments where the plume is developed under the influence of turbulence, tides and waves. This strategy includes two modules: source declaration (or identification and source verification embedded in a subsumption architecture. Algorithms for source identification are derived from the moth-inspired plume tracing strategies based on a chemical sensor. The in-water test missions, conducted in November 2002 at San Clemente Island (California, USA in June 2003 in Duck (North Carolina, USA and in October 2010 at Dalian Bay (China, successfully identified the source locations after autonomous underwater vehicles tracked the rhodamine dye plumes with a significant meander over 100 meters. The objective of the verification module is to verify the declared plume source using a visual sensor. Because images taken in near shore oceanic environments are very vague and colors in the images are not well-defined, we adopt a fuzzy color extractor to segment the color components and recognize the chemical plume and its source by measuring color similarity. The source verification module is tested by images taken during the CPT missions.

  18. Compression and Combining Based on Channel Shortening and Rank Reduction Technique for Cooperative Wireless Sensor Networks

    KAUST Repository

    Ahmed, Qasim Zeeshan

    2013-12-18

    This paper investigates and compares the performance of wireless sensor networks where sensors operate on the principles of cooperative communications. We consider a scenario where the source transmits signals to the destination with the help of L sensors. As the destination has the capacity of processing only U out of these L signals, the strongest U signals are selected while the remaining (L?U) signals are suppressed. A preprocessing block similar to channel-shortening is proposed in this contribution. However, this preprocessing block employs a rank-reduction technique instead of channel-shortening. By employing this preprocessing, we are able to decrease the computational complexity of the system without affecting the bit error rate (BER) performance. From our simulations, it can be shown that these schemes outperform the channel-shortening schemes in terms of computational complexity. In addition, the proposed schemes have a superior BER performance as compared to channel-shortening schemes when sensors employ fixed gain amplification. However, for sensors which employ variable gain amplification, a tradeoff exists in terms of BER performance between the channel-shortening and these schemes. These schemes outperform channel-shortening scheme for lower signal-to-noise ratio.

  19. Laterally Driven Resonant Pressure Sensor with Etched Silicon Dual Diaphragms and Combined Beams

    Directory of Open Access Journals (Sweden)

    Xiaohui Du

    2016-01-01

    Full Text Available A novel structure of the resonant pressure sensor is presented in this paper, which tactfully employs intercoupling between dual pressure-sensing diaphragms and a laterally driven resonant strain gauge. After the resonant pressure sensor principle is introduced, the coupling mechanism of the diaphragms and resonator is analyzed and the frequency equation of the resonator based on the triangle geometry theory is developed for this new coupling structure. The finite element (FE simulation results match the theoretical analysis over the full scale of the device. This pressure sensor was first fabricated by dry/wet etching and thermal silicon bonding, followed by vacuum-packaging using anodic bonding technology. The test maximum error of the fabricated sensor is 0.0310%F.S. (full scale in the range of 30 to 190 kPa, its pressure sensitivity is negative and exceeding 8 Hz/kPa, and its Q-factor reaches 20,000 after wafer vacuum-packaging. A novel resonant pressure sensor with high accuracy is presented in this paper.

  20. Laterally Driven Resonant Pressure Sensor with Etched Silicon Dual Diaphragms and Combined Beams.

    Science.gov (United States)

    Du, Xiaohui; Liu, Yifang; Li, Anlin; Zhou, Zhou; Sun, Daoheng; Wang, Lingyun

    2016-01-26

    A novel structure of the resonant pressure sensor is presented in this paper, which tactfully employs intercoupling between dual pressure-sensing diaphragms and a laterally driven resonant strain gauge. After the resonant pressure sensor principle is introduced, the coupling mechanism of the diaphragms and resonator is analyzed and the frequency equation of the resonator based on the triangle geometry theory is developed for this new coupling structure. The finite element (FE) simulation results match the theoretical analysis over the full scale of the device. This pressure sensor was first fabricated by dry/wet etching and thermal silicon bonding, followed by vacuum-packaging using anodic bonding technology. The test maximum error of the fabricated sensor is 0.0310%F.S. (full scale) in the range of 30 to 190 kPa, its pressure sensitivity is negative and exceeding 8 Hz/kPa, and its Q-factor reaches 20,000 after wafer vacuum-packaging. A novel resonant pressure sensor with high accuracy is presented in this paper.

  1. Handheld and mobile hyperspectral imaging sensors for wide-area standoff detection of explosives and chemical warfare agents

    Science.gov (United States)

    Gomer, Nathaniel R.; Gardner, Charles W.; Nelson, Matthew P.

    2016-05-01

    Hyperspectral imaging (HSI) is a valuable tool for the investigation and analysis of targets in complex background with a high degree of autonomy. HSI is beneficial for the detection of threat materials on environmental surfaces, where the concentration of the target of interest is often very low and is typically found within complex scenery. Two HSI techniques that have proven to be valuable are Raman and shortwave infrared (SWIR) HSI. Unfortunately, current generation HSI systems have numerous size, weight, and power (SWaP) limitations that make their potential integration onto a handheld or field portable platform difficult. The systems that are field-portable do so by sacrificing system performance, typically by providing an inefficient area search rate, requiring close proximity to the target for screening, and/or eliminating the potential to conduct real-time measurements. To address these shortcomings, ChemImage Sensor Systems (CISS) is developing a variety of wide-field hyperspectral imaging systems. Raman HSI sensors are being developed to overcome two obstacles present in standard Raman detection systems: slow area search rate (due to small laser spot sizes) and lack of eye-safety. SWIR HSI sensors have been integrated into mobile, robot based platforms and handheld variants for the detection of explosives and chemical warfare agents (CWAs). In addition, the fusion of these two technologies into a single system has shown the feasibility of using both techniques concurrently to provide higher probability of detection and lower false alarm rates. This paper will provide background on Raman and SWIR HSI, discuss the applications for these techniques, and provide an overview of novel CISS HSI sensors focused on sensor design and detection results.

  2. An Informatics Approach to Evaluating Combined Chemical Exposures from Consumer Products: A Case Study of Asthma-Associated Chemicals and Potential Endocrine Disruptors.

    Science.gov (United States)

    Gabb, Henry A; Blake, Catherine

    2016-08-01

    Simultaneous or sequential exposure to multiple environmental stressors can affect chemical toxicity. Cumulative risk assessments consider multiple stressors but it is impractical to test every chemical combination to which people are exposed. New methods are needed to prioritize chemical combinations based on their prevalence and possible health impacts. We introduce an informatics approach that uses publicly available data to identify chemicals that co-occur in consumer products, which account for a significant proportion of overall chemical load. Fifty-five asthma-associated and endocrine disrupting chemicals (target chemicals) were selected. A database of 38,975 distinct consumer products and 32,231 distinct ingredient names was created from online sources, and PubChem and the Unified Medical Language System were used to resolve synonymous ingredient names. Synonymous ingredient names are different names for the same chemical (e.g., vitamin E and tocopherol). Nearly one-third of the products (11,688 products, 30%) contained ≥ 1 target chemical and 5,229 products (13%) contained > 1. Of the 55 target chemicals, 31 (56%) appear in ≥ 1 product and 19 (35%) appear under more than one name. The most frequent three-way chemical combination (2-phenoxyethanol, methyl paraben, and ethyl paraben) appears in 1,059 products. Further work is needed to assess combined chemical exposures related to the use of multiple products. The informatics approach increased the number of products considered in a traditional analysis by two orders of magnitude, but missing/incomplete product labels can limit the effectiveness of this approach. Such an approach must resolve synonymy to ensure that chemicals of interest are not missed. Commonly occurring chemical combinations can be used to prioritize cumulative toxicology risk assessments. Gabb HA, Blake C. 2016. An informatics approach to evaluating combined chemical exposures from consumer products: a case study of asthma

  3. An Informatics Approach to Evaluating Combined Chemical Exposures from Consumer Products: A Case Study of Asthma-Associated Chemicals and Potential Endocrine Disruptors

    Science.gov (United States)

    Gabb, Henry A.; Blake, Catherine

    2016-01-01

    Background: Simultaneous or sequential exposure to multiple environmental stressors can affect chemical toxicity. Cumulative risk assessments consider multiple stressors but it is impractical to test every chemical combination to which people are exposed. New methods are needed to prioritize chemical combinations based on their prevalence and possible health impacts. Objectives: We introduce an informatics approach that uses publicly available data to identify chemicals that co-occur in consumer products, which account for a significant proportion of overall chemical load. Methods: Fifty-five asthma-associated and endocrine disrupting chemicals (target chemicals) were selected. A database of 38,975 distinct consumer products and 32,231 distinct ingredient names was created from online sources, and PubChem and the Unified Medical Language System were used to resolve synonymous ingredient names. Synonymous ingredient names are different names for the same chemical (e.g., vitamin E and tocopherol). Results: Nearly one-third of the products (11,688 products, 30%) contained ≥ 1 target chemical and 5,229 products (13%) contained > 1. Of the 55 target chemicals, 31 (56%) appear in ≥ 1 product and 19 (35%) appear under more than one name. The most frequent three-way chemical combination (2-phenoxyethanol, methyl paraben, and ethyl paraben) appears in 1,059 products. Further work is needed to assess combined chemical exposures related to the use of multiple products. Conclusions: The informatics approach increased the number of products considered in a traditional analysis by two orders of magnitude, but missing/incomplete product labels can limit the effectiveness of this approach. Such an approach must resolve synonymy to ensure that chemicals of interest are not missed. Commonly occurring chemical combinations can be used to prioritize cumulative toxicology risk assessments. Citation: Gabb HA, Blake C. 2016. An informatics approach to evaluating combined chemical

  4. Ram-air sample collection device for a chemical warfare agent sensor

    Science.gov (United States)

    Megerle, Clifford A.; Adkins, Douglas R.; Frye-Mason, Gregory C.

    2002-01-01

    In a surface acoustic wave sensor mounted within a body, the sensor having a surface acoustic wave array detector and a micro-fabricated sample preconcentrator exposed on a surface of the body, an apparatus for collecting air for the sensor, comprising a housing operatively arranged to mount atop the body, the housing including a multi-stage channel having an inlet and an outlet, the channel having a first stage having a first height and width proximate the inlet, a second stage having a second lower height and width proximate the micro-fabricated sample preconcentrator, a third stage having a still lower third height and width proximate the surface acoustic wave array detector, and a fourth stage having a fourth height and width proximate the outlet, where the fourth height and width are substantially the same as the first height and width.

  5. Nanowire Chemical/Biological Sensors: Status and a Roadmap for the Future.

    Science.gov (United States)

    Fennell, John F; Liu, Sophie F; Azzarelli, Joseph M; Weis, Jonathan G; Rochat, Sébastien; Mirica, Katherine A; Ravnsbæk, Jens B; Swager, Timothy M

    2016-01-22

    Chemiresistive sensors are becoming increasingly important as they offer an inexpensive option to conventional analytical instrumentation, they can be readily integrated into electronic devices, and they have low power requirements. Nanowires (NWs) are a major theme in chemosensor development. High surface area, interwire junctions, and restricted conduction pathways give intrinsically high sensitivity and new mechanisms to transduce the binding or action of analytes. This Review details the status of NW chemosensors with selected examples from the literature. We begin by proposing a principle for understanding electrical transport and transduction mechanisms in NW sensors. Next, we offer the reader a review of device performance parameters. Then, we consider the different NW types followed by a summary of NW assembly and different device platform architectures. Subsequently, we discuss NW functionalization strategies. Finally, we propose future developments in NW sensing to address selectivity, sensor drift, sensitivity, response analysis, and emerging applications.

  6. Impact of chemical peeling combined with negative pressure on human skin.

    Science.gov (United States)

    Kim, S J; Kang, I J; Shin, M K; Jeong, K H; Baek, J H; Koh, J S; Lee, S J

    2016-10-01

    In vivo changes in skin barrier function after chemical peeling with alpha hydroxyacids (AHAs) have been previously reported. However, the additional effects of physical treatment with chemical agents on skin barrier function have not been adequately studied. This study measured the degree of acute skin damage and the time required for skin barrier repair using non-invasive bioengineering methods in vivo with human skin to investigate the additional effect of a 4% AHA chemical jet accelerated at supersonic velocities. Thirteen female subjects (average age: 29.54 ± 4.86 years) participated in this study. The faces of the subjects were divided into half according to the block randomization design and were then assigned to receive AHA peeling alone or AHA peeling combined with pneumatic pressure on each side of the face. Transepidermal water loss (TEWL), skin colour and skin blood flow were evaluated at baseline and at 30 min, 2, 5 and 7 days after treatment. The TEWL and skin blood flow were significantly increased after 30 min in chemodermabrasion compared with chemical peeling alone (P skin blood flow recovered to baseline after 2 days, and TEWL was significantly decreased at 7 days compared with chemical peeling alone (P skin barriers, but it is estimated that it can enhance the skin barrier function after 7 days compared to the use of a chemical agent alone. In addition, chemodermabrasion has a more effective impact in the dermis and relatively preserves the skin barrier. © 2016 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  7. Quality fluctuation detection of an herbal injection based on biological fingerprint combined with chemical fingerprint.

    Science.gov (United States)

    Zhang, Lele; Ma, Lina; Feng, Wuwen; Zhang, Congen; Sheng, Feiya; Zhang, Yi; Xu, Chen; Dong, Gang; Dong, Xiaoping; Xiao, Xiaohe; Yan, Dan

    2014-08-01

    Herbal injection is one of the most important preparations of traditional Chinese medicine. More than 130 types of herbal injections are used clinically for 400 million patients annually with total sales of over four billion US dollars per year. However, the current quality control (QC) methods relying mainly on chemical fingerprints (CF) can hardly ensure quality and safety of the herbal injections with complex chemical composition and have resulted in an increase in serious adverse drug reactions. In this study, a comprehensive approach for the QC of a controversial herbal injection Shuang-Huang-Lian lyophilized powder (SHL) was established based on the quality fluctuation detection by a combination of CF and biological fingerprint (BF). High-performance liquid chromatography and the impedance-based xCELLigence system were applied to establish the CF and BF, respectively. In addition, multivariate analysis was performed to evaluate the discriminant ability of the two methods. The results showed that being subjected to environmental influence like oxygen/air, high temperature, and extreme illumination could lead to quality fluctuation of SHL. The combination of chemical and biological fingerprint method is a more powerful tool for the QC of SHL because it can clearly discriminate different groups of abnormal samples. This method can be used for the detection of quality fluctuation of SHL and can provide reference for the quality control of other herbal injections.

  8. Research on the Interaction of Hydrogen-Bond Acidic Polymer Sensitive Sensor Materials with Chemical Warfare Agents Simulants by Inverse Gas Chromatography

    Directory of Open Access Journals (Sweden)

    Liu Yang

    2015-06-01

    Full Text Available Hydrogen-bond acidic polymers are important high affinity materials sensitive to organophosphates in the chemical warfare agent sensor detection process. Interactions between the sensor sensitive materials and chemical warfare agent simulants were studied by inverse gas chromatography. Hydrogen bonded acidic polymers, i.e., BSP3, were prepared for micro-packed columns to examine the interaction. DMMP (a nerve gas simulant and 2-CEES (a blister agent simulant were used as probes. Chemical and physical parameters such as heats of absorption and Henry constants of the polymers to DMMP and 2-CEES were determined by inverse gas chromatography. Details concerning absorption performance are also discussed in this paper.

  9. Research on the interaction of hydrogen-bond acidic polymer sensitive sensor materials with chemical warfare agents simulants by inverse gas chromatography.

    Science.gov (United States)

    Yang, Liu; Han, Qiang; Cao, Shuya; Huang, Feng; Qin, Molin; Guo, Chenghai; Ding, Mingyu

    2015-06-02

    Hydrogen-bond acidic polymers are important high affinity materials sensitive to organophosphates in the chemical warfare agent sensor detection process. Interactions between the sensor sensitive materials and chemical warfare agent simulants were studied by inverse gas chromatography. Hydrogen bonded acidic polymers, i.e., BSP3, were prepared for micro-packed columns to examine the interaction. DMMP (a nerve gas simulant) and 2-CEES (a blister agent simulant) were used as probes. Chemical and physical parameters such as heats of absorption and Henry constants of the polymers to DMMP and 2-CEES were determined by inverse gas chromatography. Details concerning absorption performance are also discussed in this paper.

  10. Cobalt toxicity: Chemical and radiological combined effects on HaCaT keratinocyte cell line

    Energy Technology Data Exchange (ETDEWEB)

    Sandre, C.; Moulin, C.; Bresson, C. [CEA Saclay, DEN, SECR, Lab Speciat Radionucleides and Mol, F-91191 Gif Sur Yvette (France); Gault, N. [CEA Fontenay Roses, DSV IRCM SCSR LRTS, F-92265 Fontenay Aux Roses (France); Poncy, J. L. [CEA Bruyeres Le Chatel, DSV IRCM SREIT LRT, F-91680 Bruyeres Le Chatel (France); Lefaix, J. L. [CEA Caen, DSV IRCM SRO LARIA, F-14070 Caen (France)

    2010-07-01

    Cobalt (Co) is an essential trace element well known as a constituent of vitamin B{sub 12}, but different compounds of Co are also described as highly toxic and/or radio-toxic for individuals or the environment. In nuclear power plants, {sup 58}Co and {sup 60}Co are radioactive isotopes of cobalt present as activation products of stable Co and Ni used in alloys. Skin exposure is a current occupational risk in the hard metal and nuclear industries. As biochemical and molecular cobalt-induced toxicological mechanisms are not fully identified, we investigated cobalt toxicity in a model human keratinocyte cell line, HaCaT. In this study, we propose a model to determine the in vitro chemical impact on cell viability of a soluble form of cobalt (CoCl{sub 2}) with or without gamma-ray doses to mimic contamination by {sup 60}Co, to elucidate the mechanisms of cobalt intracellular chemical and radiological toxicity. Intracellular cobalt concentration was determined after HaCaT cell contamination and chemical toxicity was evaluated in terms of cellular viability and clonogenic survival. We investigated damage to DNA in HaCaT cells by combined treatment with chemical cobalt and a moderate gamma-ray dose. Additive effects of cobalt and irradiation were demonstrated. The underlying mechanism of cobalt toxicity is not clearly established, but our results seem to indicate that the toxicity of Co(II) and of irradiation arises from production of reactive oxygen species. (authors)

  11. Cobalt toxicity: Chemical and radiological combined effects on HaCaT keratinocyte cell line

    Energy Technology Data Exchange (ETDEWEB)

    Gault, N. [CEA Fontenay aux Roses, DSV/IRCM/SCSR/LRTS, 92265 Fontenay aux Rose (France); Sandre, C.; Moulin, B.; Bresson, C. [CEA, DEN, SECR, Laboratoire de Speciation des Radionucleides et des Molecules, F-91191 Gif-sur-Yvette (France); Poncy, J.L. [CEA Bruyeres Le Chatel, DSV/IRCM/SREIT/LRT, 91680 Bruyeres Le Chatel (France); Lefaix, J.L. [CEA Caen, DSV/IRCM/SRO/LARIA, 14070 Caen (France)

    2010-07-01

    Cobalt (Co) is an essential trace element well known as a constituent of vitamin B12, but different compounds of Co are also described as highly toxic and/or radio-toxic for individuals or the environment. In nuclear power plants, {sup 58}Co and {sup 60}Co are radioactive isotopes of cobalt present as activation products of stable Co and Ni used in alloys. Skin exposure is a current occupational risk in the hard metal and nuclear industries. As biochemical and molecular cobalt-induced toxicological mechanisms are not fully identified, we investigated cobalt toxicity in a model human keratinocyte cell line, HaCaT. In this study, we propose a model to determine the in vitro chemical impact on cell viability of a soluble form of cobalt (CoCl{sub 2}) with or without {gamma}-ray doses to mimic contamination by {sup 60}Co, to elucidate the mechanisms of cobalt intracellular chemical and radiological toxicity. Intracellular cobalt concentration was determined after HaCaT cell contamination and chemical toxicity was evaluated in terms of cellular viability and clonogenic survival. We investigated damage to DNA in HaCaT cells by combined treatment with chemical cobalt and a moderate {gamma}-ray dose. Additive effects of cobalt and irradiation were demonstrated. The underlying mechanism of cobalt toxicity is not clearly established, but our results seem to indicate that the toxicity of Co(II) and of irradiation arises from production of reactive oxygen species. (authors)

  12. A combined approach of chemical enhancers and sonophoresis for the transdermal delivery of tizanidine hydrochloride.

    Science.gov (United States)

    Mutalik, Srinivas; Parekh, Harendra S; Davies, Nigel M; Udupa, Nayanabhirama

    2009-02-01

    The effects of chemical enhancers and sonophoresis on the transdermal permeation of tizanidine hydrochloride (TIZ) across mouse skin were investigated. Parameters including drug solubility, apparent partition coefficient (APC), drug permeation, and degradation in skin were determined. Low frequency ultrasound was also applied in the presence and absence of chemical enhancers to assess whether drug permeation improved. APC values indicated that TIZ preferentially partitions into intercellular spaces and does not form a reservoir, with the drug also exhibiting good enzymatic stability in skin. Most of the enhancers studied significantly increased the permeation rate of TIZ through full thickness mouse skin in comparison with TIZ formulated in phosphate buffer. Maximum enhancement was observed for TIZ formulated as a suspension in 50% v/v aqueous ethanol containing 5% v/v citral. Sonophoresis significantly (p synergistic effect was noted when sonophoresis was applied in the presence of chemical enhancers. The results suggest that the formulation of TIZ with an appropriate penetration enhancer may be useful in the development of a therapeutic system to deliver TIZ across the skin for a prolonged period, i.e. 24 hr. The application of ultrasound in association with chemical enhancers, such as the combination of 5% v/v citral in 50% v/v aqueous ethanol, could further serve as a non-oral and non-invasive drug delivery modality for the immediate therapeutic effect of muscle relaxants such as TIZ.

  13. Bendable Electro-chemical Lactate Sensor Printed with Silver Nano-particles

    Science.gov (United States)

    Abrar, Md Abu; Dong, Yue; Lee, Paul Kyuheon; Kim, Woo Soo

    2016-07-01

    Here we report a flexible amperometric lactate biosensor using silver nanoparticle based conductive electrode. Mechanically bendable cross-serpentine-shaped silver electrode is generated on flexible substrate for the mechanical durability such as bending. The biosensor is designed and fabricated by modifying silver electrode with lactate oxidase immobilized by bovine serum albumin. The in-sensor pseudo Ag/AgCl reference electrode is fabricated by chloridization of silver electrode, which evinced its long-term potential stability against a standard commercial Ag/AgCl reference electrode. The amperometric response of the sensor shows linear dependence with lactate concentration of 1~25 mM/L. Anionic selectivity is achieved by using drop-casted Nafion coated on silver electrode against anionic interferences such as ascorbate. This non-invasive electrochemical lactate sensor also demonstrates excellent resiliency against mechanical deformation and temperature fluctuation which leads the possibility of using it on human epidermis for continuous measurement of lactate from sweat. Near field communication based wireless data transmission is demonstrated to reflect a practical approach of the sensor to measure lactate concentration portably using human perspiration.

  14. Low-Power, Antifuse-Based Silicon Chemical Sensor on a Suspended Membrane

    NARCIS (Netherlands)

    Kovalgin, A.Y.; Holleman, J.; Iordache, G.; Jenneboer, T.; Falke, F.; Zieren, V.; Goossens, M.J.

    2006-01-01

    In this paper we describe a new, simple, and cheap silicon sensor operating at a high temperature of about 1000 K and consuming a very low power of a few milliwatts. We developed a silicon-processing compatible, simple, and low-cost method for processing thermally isolated suspended membranes. This

  15. CRIM-TRACK: Sensor System for Detection of Criminal Chemical Substances

    DEFF Research Database (Denmark)

    Munk, Jens Kristian; Buus, Ole Thomsen; Larsen, Jan;

    2015-01-01

    and precursors thereof in laboratory settings. Using colorimetric technology we have developed prototypes that employ disposable sensing chips. Ease of operation and intuitive sensor response are highly prioritized features that we implement as we gather data to feed into machine learning. With machine learning...

  16. Fiber Optic-Fluorescence Sensors for Remote Detection of Chemical Species in Seawater

    Science.gov (United States)

    1989-09-01

    from the viewing volume by diffusive/convective mass transport processes and replaced by uncomplexed indicator from the reservoir. Because the flow...Morin as Fluorescence sensor for Determination of Aluminum(III) ." Anal. Chem., 1983, 55, 667-670. (10) Urbano , E., H. Offenbacher, and O.S. Wolfbeis

  17. Combined effects of prenatal exposures to environmental chemicals on birth weight

    DEFF Research Database (Denmark)

    Govarts, Eva; Remy, Sylvie; Bruckers, Liesbeth

    2016-01-01

    Prenatal chemical exposure has been frequently associated with reduced fetal growth by single pollutant regression models although inconsistent results have been obtained. Our study estimated the effects of exposure to single pollutants and mixtures on birth weight in 248 mother-child pairs...... over the duration of gestation. In single pollutant models, arsenic was significantly associated with reduced birth weight. The effect estimate increased when including cadmium, and mono-(2-ethyl-5-carboxypentyl) phthalate (MECPP) co-exposure. Combining exposures by principal component analysis...... with cadmium showed the strongest association with birth weight. In conclusion, birth weight was consistently inversely associated with exposure to pollutant mixtures. Chemicals not showing significant associations at single pollutant level contributed to stronger effects when analyzed as mixtures....

  18. Innovative Strategies to Develop Chemical Categories Using a Combination of Structural and Toxicological Properties

    Science.gov (United States)

    Batke, Monika; Gütlein, Martin; Partosch, Falko; Gundert-Remy, Ursula; Helma, Christoph; Kramer, Stefan; Maunz, Andreas; Seeland, Madeleine; Bitsch, Annette

    2016-01-01

    Interest is increasing in the development of non-animal methods for toxicological evaluations. These methods are however, particularly challenging for complex toxicological endpoints such as repeated dose toxicity. European Legislation, e.g., the European Union's Cosmetic Directive and REACH, demands the use of alternative methods. Frameworks, such as the Read-across Assessment Framework or the Adverse Outcome Pathway Knowledge Base, support the development of these methods. The aim of the project presented in this publication was to develop substance categories for a read-across with complex endpoints of toxicity based on existing databases. The basic conceptual approach was to combine structural similarity with shared mechanisms of action. Substances with similar chemical structure and toxicological profile form candidate categories suitable for read-across. We combined two databases on repeated dose toxicity, RepDose database, and ELINCS database to form a common database for the identification of categories. The resulting database contained physicochemical, structural, and toxicological data, which were refined and curated for cluster analyses. We applied the Predictive Clustering Tree (PCT) approach for clustering chemicals based on structural and on toxicological information to detect groups of chemicals with similar toxic profiles and pathways/mechanisms of toxicity. As many of the experimental toxicity values were not available, this data was imputed by predicting them with a multi-label classification method, prior to clustering. The clustering results were evaluated by assessing chemical and toxicological similarities with the aim of identifying clusters with a concordance between structural information and toxicity profiles/mechanisms. From these chosen clusters, seven were selected for a quantitative read-across, based on a small ratio of NOAEL of the members with the highest and the lowest NOAEL in the cluster (cluster and to use this information for a

  19. Improvement of process identification and discharge measurement by the combination of different sensors

    Science.gov (United States)

    Schimmel, Andreas; Hübl, Johannes; Koschuch, Richard

    2016-04-01

    The Lattenbach is a very active torrent located in a geologic fault zone in the western part of Austria with a catchment area of 5,3 km², feeding the river Sanna, which is a tributary of the river Inn. The highest elevation in the watershed is around 2900 m above sea level (asl), the confluence with the river Sanna at 840 m asl. Both, the village Grins in the middle reach of the torrent and the village Pians at the outlet of the catchment, are affected by the hydrologic and geomorphic processes within the watershed. Aside from the 'regular' flood events with bedload transport in spring and summer, the torrent produced five debris flows and three debris flow-like events within the last years (16/08/15, 09/08/15, 26/08/12, 10/07/10, 01/09/08, 20/06/07, 30/08/07 and 22/08/05, respectively). Due to the frequent debris flow and debris flood events the torrent is monitored by the Institute of Mountain Risk Engineering since several years. The parameters that are currently measured during an event includes meteorological data (rainfall, temperature, etc.) in the upper part of the catchment (station Dawinalpe) and run-off data from the middle and lower reach of the torrent at the villages Grins and Pians. In the last years the monitoring equipment has been improved: Since July 2013 a first version of a warning system based on a combination of infrasound and seismic data is installed at the monitoring station closed to Grins. This system is build up on a minimum of one seismic and one infrasound sensor which are co-located and a microcontroller which runs a detection algorithm to detect debris flows with high accuracy in real time directly on-site. The detection algorithm is based on an analyses of the evolution in time of the frequency content of the infrasound and seismic signals produced by a mass movement and has already been tested at several test sites in Austria, Italy and Switzerland. Further a high frequency pulse Doppler Radar has been installed which provides

  20. Voting-based consensus clustering for combining multiple clusterings of chemical structures

    Directory of Open Access Journals (Sweden)

    Saeed Faisal

    2012-12-01

    Full Text Available Abstract Background Although many consensus clustering methods have been successfully used for combining multiple classifiers in many areas such as machine learning, applied statistics, pattern recognition and bioinformatics, few consensus clustering methods have been applied for combining multiple clusterings of chemical structures. It is known that any individual clustering method will not always give the best results for all types of applications. So, in this paper, three voting and graph-based consensus clusterings were used for combining multiple clusterings of chemical structures to enhance the ability of separating biologically active molecules from inactive ones in each cluster. Results The cumulative voting-based aggregation algorithm (CVAA, cluster-based similarity partitioning algorithm (CSPA and hyper-graph partitioning algorithm (HGPA were examined. The F-measure and Quality Partition Index method (QPI were used to evaluate the clusterings and the results were compared to the Ward’s clustering method. The MDL Drug Data Report (MDDR dataset was used for experiments and was represented by two 2D fingerprints, ALOGP and ECFP_4. The performance of voting-based consensus clustering method outperformed the Ward’s method using F-measure and QPI method for both ALOGP and ECFP_4 fingerprints, while the graph-based consensus clustering methods outperformed the Ward’s method only for ALOGP using QPI. The Jaccard and Euclidean distance measures were the methods of choice to generate the ensembles, which give the highest values for both criteria. Conclusions The results of the experiments show that consensus clustering methods can improve the effectiveness of chemical structures clusterings. The cumulative voting-based aggregation algorithm (CVAA was the method of choice among consensus clustering methods.

  1. INNOVATIVE SOLUTIONS IN BIOTECHNOLOGIES OF COMBINED YOGURT DRINKS WITH BALANCED CHEMICAL CONTENTS

    Directory of Open Access Journals (Sweden)

    N. A. Tkachenko

    2017-10-01

    Full Text Available Expediency of development of recipes and innovative biotechnologies for combined milk-vegetational products with balanced chemical composition, strengthened probiotic properties and extended shelf life was proven in field of establishing proper diet for adult healthy people, both in everyday consumption and during treatment of illnesses and rehabilitation after it. Principles of scientific approach to creation of biotechnologies for fermented combined products with balance of basic food nutrients are described here, as well as innovative biotechnological approaches, which provide the possibility of getting desired products (yoghurt drinks with high probiotic properties and long shelf life. Main stages of development are described for recipes and biotechnologies of bifido-enabled combined yoghurt drinks with balanced chemical composition, rich on lively bifido- and Lactobacterium cells and long shelf life. A scheme for production of desired products with explanation of technological process parameters is provided, it was tested in industrial conditions at “Gormolzavod №1” Ltd. in Odesa, Ukraine. In samples of milk-rice and milk-spelt yoghurt drinks, which were produced in industrial conditions, we determined chemical composition and primary quality objectives. Desired products have balanced ratio of proteins : fats : carbohydrates (1 : 1 : 4, high sensory qualities, standard quality values during long shelf life (20 days in sealed tare, contain a high concentration of viable cells of probiotic cultures – such as B. animalis Bb-12 (not less than 3.6∙108 CFU / cm3 and mixed cultures of L. bulgaricus + S. thermophilus (not less than 4.0∙108 CFU/cm3, as well as physiologically significant number of prebiotics – lactulose and fiber (30 and 10%, according to the daily consumption norm when consuming 500 cm3 of product.

  2. A Combined Solar Electric and Storable Chemical Propulsion Vehicle for Piloted Mars Missions

    Science.gov (United States)

    Mercer, Carolyn R.; Oleson, Steven R.; Drake, Bret G.

    2014-01-01

    The Mars Design Reference Architecture (DRA) 5.0 explored a piloted Mars mission in the 2030 timeframe, focusing on architecture and technology choices. The DRA 5.0 focused on nuclear thermal and cryogenic chemical propulsion system options for the mission. Follow-on work explored both nuclear and solar electric options. One enticing option that was found in a NASA Collaborative Modeling for Parametric Assessment of Space Systems (COMPASS) design study used a combination of a 1-MW-class solar electric propulsion (SEP) system combined with storable chemical systems derived from the planned Orion crew vehicle. It was found that by using each propulsion system at the appropriate phase of the mission, the entire SEP stage and habitat could be placed into orbit with just two planned Space Launch System (SLS) heavy lift launch vehicles assuming the crew would meet up at the Earth-Moon (E-M) L2 point on a separate heavy-lift launch. These appropriate phases use high-thrust chemical propulsion only in gravity wells when the vehicle is piloted and solar electric propulsion for every other phase. Thus the SEP system performs the spiral of the unmanned vehicle from low Earth orbit (LEO) to E-M L2 where the vehicle meets up with the multi-purpose crew vehicle. From here SEP is used to place the vehicle on a trajectory to Mars. With SEP providing a large portion of the required capture and departure changes in velocity (delta V) at Mars, the delta V provided by the chemical propulsion is reduced by a factor of five from what would be needed with chemical propulsion alone at Mars. This trajectory also allows the SEP and habitat vehicle to arrive in the highly elliptic 1-sol parking orbit compatible with envisioned Mars landing concepts. This paper explores mission options using between SEP and chemical propulsion, the design of the SEP system including the solar array and electric propulsion systems, and packaging in the SLS shroud. Design trades of stay time, power level

  3. Lifetimes of organic photovoltaics: Combining chemical and physical characterisation techniques to study degradation mechanisms

    DEFF Research Database (Denmark)

    Norrman, K.; Larsen, N.B.; Krebs, Frederik C

    2006-01-01

    Degradation mechanisms of a photovoltaic device with an Al/C-60/C-12-PSV/PEDOT:PSS/ITO/glass geometry was studied using a combination of in-plane physical and chemical analysis techniques: TOF-SIMS, AFM, SEM, interference microscopy and fluorescence microscopy. A comparison was made between...... a device being stored in darkness in air and a device that had been subjected to illumination under simulated sunlight (1000 Wm(-2), AM1.5) in air. It was found that oxygen diffuses through pinholes in the aluminium electrode. If stored in air in the dark the oxidation is limited to the C-60 layer...

  4. Chemical cross-linking and native mass spectrometry: A fruitful combination for structural biology.

    Science.gov (United States)

    Sinz, Andrea; Arlt, Christian; Chorev, Dror; Sharon, Michal

    2015-08-01

    Mass spectrometry (MS) is becoming increasingly popular in the field of structural biology for analyzing protein three-dimensional-structures and for mapping protein-protein interactions. In this review, the specific contributions of chemical crosslinking and native MS are outlined to reveal the structural features of proteins and protein assemblies. Both strategies are illustrated based on the examples of the tetrameric tumor suppressor protein p53 and multisubunit vinculin-Arp2/3 hybrid complexes. We describe the distinct advantages and limitations of each technique and highlight synergistic effects when both techniques are combined. Integrating both methods is especially useful for characterizing large protein assemblies and for capturing transient interactions. We also point out the future directions we foresee for a combination of in vivo crosslinking and native MS for structural investigation of intact protein assemblies.

  5. [Pollutant source apportionment of combined sewer overflows using chemical mass balance method].

    Science.gov (United States)

    Dai, Mei-Hong; Li, Tian; Zhang, Wei

    2013-11-01

    Pollutant characteristics of surface runoff, sanitary sewage and sewer deposits from a combined sewer system in Shanghai were studied. It was confirmed that the content of Zn, NH4(+) -N, P, respectively in surface runoff, sanitary sewage and sewer deposits was specific and relatively stable based on contrasting pollutant characteristics of different sources. Three non-dimensional parameters-Zn/P, NH4(+) -N/Zn, P/K were proposed as characteristic index for surface runoff, sanitary sewage and sewer deposits. In order to find sources of pollutants in CSO, the application of chemical mass balance method was discussed: the average contributions to CSO were 42.8% for surface runoff, 12.2% for sanitary sewage, 23.8% for sewer deposits, and the results basically reflected the composition of CSO pollution. The research method and results can provide guidance for pollutant source apportionment of combined sewer overflows.

  6. Combined Geometric and Neural Network Approach to Generic Fault Diagnosis in Satellite Actuators and Sensors

    DEFF Research Database (Denmark)

    Baldi, P.; Blanke, Mogens; Castaldi, P.

    2016-01-01

    This paper presents a novel scheme for diagnosis of faults affecting the sensors measuring the satellite attitude, body angular velocity and flywheel spin rates as well as defects related to the control torques provided by satellite reaction wheels. A nonlinear geometric design is used to avoid...... on a detailed nonlinear satellite model with embedded disturbance description. The results document the efficacy of the proposed diagnosis scheme....

  7. Combined Geometric and Neural Network Approach to Generic Fault Diagnosis in Satellite Actuators and Sensors

    OpenAIRE

    Baldi, P.; Blanke, Mogens; P. Castaldi; Mimmo, N.; S. Simani

    2016-01-01

    This paper presents a novel scheme for diagnosis of faults affecting the sensors measuring the satellite attitude, body angular velocity and flywheel spin rates as well as defects related to the control torques provided by satellite reaction wheels. A nonlinear geometric design is used to avoid that aerodynamic disturbance torques have unwanted influence on the residuals exploited for fault detection and isolation. Radial basis function neural networks are used to obtain fault estimation filt...

  8. Combining Multi-Agent Systems and Wireless Sensor Networks for Monitoring Crop Irrigation.

    Science.gov (United States)

    Villarrubia, Gabriel; Paz, Juan F De; Iglesia, Daniel H De La; Bajo, Javier

    2017-08-02

    Monitoring mechanisms that ensure efficient crop growth are essential on many farms, especially in certain areas of the planet where water is scarce. Most farmers must assume the high cost of the required equipment in order to be able to streamline natural resources on their farms. Considering that many farmers cannot afford to install this equipment, it is necessary to look for more effective solutions that would be cheaper to implement. The objective of this study is to build virtual organizations of agents that can communicate between each other while monitoring crops. A low cost sensor architecture allows farmers to monitor and optimize the growth of their crops by streamlining the amount of resources the crops need at every moment. Since the hardware has limited processing and communication capabilities, our approach uses the PANGEA architecture to overcome this limitation. Specifically, we will design a system that is capable of collecting heterogeneous information from its environment, using sensors for temperature, solar radiation, humidity, pH, moisture and wind. A major outcome of our approach is that our solution is able to merge heterogeneous data from sensors and produce a response adapted to the context. In order to validate the proposed system, we present a case study in which farmers are provided with a tool that allows us to monitor the condition of crops on a TV screen using a low cost device.

  9. Combining Multi-Agent Systems and Wireless Sensor Networks for Monitoring Crop Irrigation

    Directory of Open Access Journals (Sweden)

    Gabriel Villarrubia

    2017-08-01

    Full Text Available Monitoring mechanisms that ensure efficient crop growth are essential on many farms, especially in certain areas of the planet where water is scarce. Most farmers must assume the high cost of the required equipment in order to be able to streamline natural resources on their farms. Considering that many farmers cannot afford to install this equipment, it is necessary to look for more effective solutions that would be cheaper to implement. The objective of this study is to build virtual organizations of agents that can communicate between each other while monitoring crops. A low cost sensor architecture allows farmers to monitor and optimize the growth of their crops by streamlining the amount of resources the crops need at every moment. Since the hardware has limited processing and communication capabilities, our approach uses the PANGEA architecture to overcome this limitation. Specifically, we will design a system that is capable of collecting heterogeneous information from its environment, using sensors for temperature, solar radiation, humidity, pH, moisture and wind. A major outcome of our approach is that our solution is able to merge heterogeneous data from sensors and produce a response adapted to the context. In order to validate the proposed system, we present a case study in which farmers are provided with a tool that allows us to monitor the condition of crops on a TV screen using a low cost device.

  10. Rhythmic chemical reaction of CO on the surface of a SnO 2 gas sensor

    Science.gov (United States)

    Nakata, S.; Kato, Y.; Kaneda, Y.; Yoshikawa, K.

    1996-12-01

    The oscillatory phenomenon of the oxidative reaction of CO on an n-type semiconductor surface is reported. As a semiconductor, we used a SnO 2 gas sensor, which is widely used for practical application. Various characteristics in the time series of the conductance were observed and analyzed with next amplitude mapping and Fourier power spectra. The simultaneous measurement of the temperature on the semiconductor surface and the conductance suggested that the temperature change was a key variable in the oscillatory phenomenon. As a preliminary theoretical model, a simulation was performed using the surface concentration of CO and the temperature as two independent variables. The present study is part of our attempt to use a time-dependent nonlinear response for the development of an intelligent sensor which mimics sensory mechanisms in living organisms.

  11. A Highly-Sensitive Picric Acid Chemical Sensor Based on ZnO Nanopeanuts

    Directory of Open Access Journals (Sweden)

    Ahmed A. Ibrahim

    2017-07-01

    Full Text Available Herein, we report a facile synthesis, characterization, and electrochemical sensing application of ZnO nanopeanuts synthesized by a simple aqueous solution process and characterized by various techniques in order to confirm the compositional, morphological, structural, crystalline phase, and optical properties of the synthesized material. The detailed characterizations revealed that the synthesized material possesses a peanut-shaped morphology, dense growth, and a wurtzite hexagonal phase along with good crystal and optical properties. Further, to ascertain the useful properties of the synthesized ZnO nanopeanut as an excellent electron mediator, electrochemical sensors were fabricated based on the form of a screen printed electrode (SPE. Electrochemical and current-voltage characteristics were studied for the determination of picric acid sensing characteristics. The electrochemical sensor fabricated based on the SPE technique exhibited a reproducible and reliable sensitivity of ~1.2 μA/mM (9.23 μA·mM−1·cm−2, a lower limit of detection at 7.8 µM, a regression coefficient (R2 of 0.94, and good linearity over the 0.0078 mM to 10.0 mM concentration range. In addition, the sensor response was also tested using simple I-V techniques, wherein a sensitivity of 493.64 μA·mM−1·cm−2, an experimental Limit of detection (LOD of 0.125 mM, and a linear dynamic range (LDR of 1.0 mM–5.0 mM were observed for the fabricated picric acid sensor.

  12. The Present State of Amperometric Nanowire Sensors for Chemical and Biological Detection

    Science.gov (United States)

    2006-10-01

    can also be used to reset the sensor by desorbing the bound species and releasing charge trapped at the interfaces which causes hysteresis (5, 17...susceptible to surface chemistry and can result in long term stability issues. Trapped charges may produce hysteresis effects. Adsorbed...Functional Materials 2004, 14 (10), 943–956. 9. Wang, X. D.; Summers, C. J.; Wang, Z. L. Mesoporous single-crystal ZnO nanowires epitaxially sheathed with

  13. Literature search, review, and compilation of data for chemical and radiochemical sensors: Task 1 report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-01-01

    During the next several decades, the US Department of Energy is expected to spend tens of billions of dollars in the characterization, cleanup, and monitoring of DOE`s current and former installations that have various degrees of soil and groundwater contamination made up of both hazardous and mixed wastes. Each of these phases will require site surveys to determine type and quantity of hazardous and mixed wastes. It is generally recognized that these required survey and monitoring efforts cannot be performed using traditional chemistry methods based on laboratory evaluation of samples from the field. For that reason, a tremendous push during the past decade or so has been made on research and development of sensors. This report contains the results of an extensive literature search on sensors that are used or have applicability in environmental and waste management. While restricting the search to a relatively small part of the total chemistry spectrum, a sizable body of reference material is included. Results are presented in tabular form for general references obtained from data base searches, as narrative reviews of relevant chapters from proceedings, as book reviews, and as reviews of journal articles with particular relevance to the review. Four broad sensor types are covered: electrochemical processes, piezoelectric devices, fiber optics, and radiochemical processes. The topics of surface chemistry processes and biosensors are not treated separately because they often are an adjunct to one of the four sensors listed. About 1,000 tabular entries are listed, including selected journal articles, reviews of conference/meeting proceedings, and books. Literature to about mid-1992 is covered.

  14. Fabrication of optical chemical ammonia sensors using anodized alumina supports and sol-gel method.

    Science.gov (United States)

    Markovics, Akos; Kovács, Barna

    2013-05-15

    In this comparative study, the fabrication and the sensing properties of various reflectometric optical ammonia gas sensors are described. In the first set of experiments the role of the support material was investigated on four different sensor membranes. Two of them were prepared by the adsorption of bromocresol green indicator on anodized aluminum plates. The applied anodizing voltages were 12 V and 24 V, which resulted in different dynamic ranges and response times for gaseous ammonia. The sol-gel method was used for the preparation of the other batch of sensors. These layers were coated on anodized aluminum plates (24 V) and on standard microscope cover glasses. In spite of the identical sensing chemistry, slightly different response times were measured merely because of the aluminum surface porosity. Gas molecules can remain entrapped in the pores, which results in delayed recovery time. On the other hand, the porous oxide film provides excellent adhesion, making the anodized aluminum an attractive support for the sol-gel layer.

  15. Combining wireless sensor networks and semantic middleware for an Internet of Things-based sportsman/woman monitoring application.

    Science.gov (United States)

    Rodríguez-Molina, Jesús; Martínez, José-Fernán; Castillejo, Pedro; López, Lourdes

    2013-01-31

    Wireless Sensor Networks (WSNs) are spearheading the efforts taken to build and deploy systems aiming to accomplish the ultimate objectives of the Internet of Things. Due to the sensors WSNs nodes are provided with, and to their ubiquity and pervasive capabilities, these networks become extremely suitable for many applications that so-called conventional cabled or wireless networks are unable to handle. One of these still underdeveloped applications is monitoring physical parameters on a person. This is an especially interesting application regarding their age or activity, for any detected hazardous parameter can be notified not only to the monitored person as a warning, but also to any third party that may be helpful under critical circumstances, such as relatives or healthcare centers. We propose a system built to monitor a sportsman/woman during a workout session or performing a sport-related indoor activity. Sensors have been deployed by means of several nodes acting as the nodes of a WSN, along with a semantic middleware development used for hardware complexity abstraction purposes. The data extracted from the environment, combined with the information obtained from the user, will compose the basis of the services that can be obtained.

  16. Combining Wireless Sensor Networks and Semantic Middleware for an Internet of Things-Based Sportsman/Woman Monitoring Application

    Directory of Open Access Journals (Sweden)

    Lourdes López

    2013-01-01

    Full Text Available Wireless Sensor Networks (WSNs are spearheading the efforts taken to build and deploy systems aiming to accomplish the ultimate objectives of the Internet of Things. Due to the sensors WSNs nodes are provided with, and to their ubiquity and pervasive capabilities, these networks become extremely suitable for many applications that so-called conventional cabled or wireless networks are unable to handle. One of these still underdeveloped applications is monitoring physical parameters on a person. This is an especially interesting application regarding their age or activity, for any detected hazardous parameter can be notified not only to the monitored person as a warning, but also to any third party that may be helpful under critical circumstances, such as relatives or healthcare centers. We propose a system built to monitor a sportsman/woman during a workout session or performing a sport-related indoor activity. Sensors have been deployed by means of several nodes acting as the nodes of a WSN, along with a semantic middleware development used for hardware complexity abstraction purposes. The data extracted from the environment, combined with the information obtained from the user, will compose the basis of the services that can be obtained.

  17. Self powered sensing by combining novel sensor architectures with energy harvesting

    Science.gov (United States)

    Bedekar, Vishwas Narayan

    The sensing techniques investigated in this thesis utilize piezoelectric materials, piezoresistive materials, and magnetoelectric composites. Prior studies on structural health monitoring have demonstrated the use and promise of piezoelectric sensors. In this research, impedance spectroscopy based sensing technique was investigated with respect to two parameters (i) effect of the piezoelectric vibration mode on damage index metric, and (ii) selection of frequency band through manipulation of the electrode size and shape. These results were then used to determine sensor geometry and dimensions for detecting surface defects, fatigue and corrosion. Based upon these results, power requirement for structural health monitoring sensors was determined. Next, piezoelectric materials were coupled with magnetostrictive material for novel magnetic field gradient sensing. The ceramic -- ceramic (CC) gradiometer resembles in functionality a magnetoelectric transformer. It measures the magnetic field gradient and sensitivity with respect to a reference value. The CC gradiometer designed in this study was based upon the magnetoelectric (ME) composites and utilizes the ring-dot piezoelectric transformer structure working near resonance as the basis. This study investigated the gradiometer design and characterized the performance of gradiometer based upon Terfenol--D -- PZT composites. Based upon these results, next a metal -- ceramic gradiometer consisting of PZT and nickel was designed and characterized. In this thesis, two different designs of gradiometer with nickel and PZT laminate composites were fabricated. Nickel was chosen over other materials considering its co-firing ability with PZT. It can give a better control over dimensional parameters of the gradiometer sample and further size reduction is possible with tape casting technique. Detailed theoretical analysis was conducted in order to understand the experimental results. In order to significantly reduce the power

  18. Combined heating and chemical treatment for oil recovery from aging crude oil.

    Science.gov (United States)

    Hou, Chunjuan; Jiang, Qingzhe; Song, Zhaozheng; Tan, Guorong; Shi, Zhan

    2016-07-01

    With increasing use of chemical oil displacement agents in tertiary recovery and the application of various demulsifiers for crude oil dehydration, a large amount of aging crude oil containing a high ratio of water is produced, and it is very difficult for processing and utilisation. In this article, we chose aging crude oil samples from a union station in an oilfield in China. Sample composition was analysed to demonstrate that the key of aging crude oil dehydration is the removal of solid impurities. Thus, an efficient method of combining heating and chemical treatments was developed to treat aging crude oil. It includes two steps: The first step is washing of aging crude oil with hot water with sodium dodecylbenzene sulfonate; the second step is chemical demulsification of the above mixture with hydrochloric acid and sodium chloride solution. The result showed that 2.9% of solid impurities and 29.2% of water were removed in the first step; 27.2% of oil, 24.3% of water, and 3.47% of solid impurities in the aging crude oil were recycled in the second step. A total 87.07% of aging crude oil could be solved with this method. The present two-step treatment method can ensure that the dehydration process runs normally and efficiently in the union station, making it a promising method in the recycling of aging crude oil. © The Author(s) 2016.

  19. Comparison of chemical and thermal protein denaturation by combination of computational and experimental approaches. II

    Science.gov (United States)

    Wang, Qian; Christiansen, Alexander; Samiotakis, Antonios; Wittung-Stafshede, Pernilla; Cheung, Margaret S.

    2011-11-01

    Chemical and thermal denaturation methods have been widely used to investigate folding processes of proteins in vitro. However, a molecular understanding of the relationship between these two perturbation methods is lacking. Here, we combined computational and experimental approaches to investigate denaturing effects on three structurally different proteins. We derived a linear relationship between thermal denaturation at temperature Tb and chemical denaturation at another temperature Tu using the stability change of a protein (ΔG). For this, we related the dependence of ΔG on temperature, in the Gibbs-Helmholtz equation, to that of ΔG on urea concentration in the linear extrapolation method, assuming that there is a temperature pair from the urea (Tu) and the aqueous (Tb) ensembles that produces the same protein structures. We tested this relationship on apoazurin, cytochrome c, and apoflavodoxin using coarse-grained molecular simulations. We found a linear correlation between the temperature for a particular structural ensemble in the absence of urea, Tb, and the temperature of the same structural ensemble at a specific urea concentration, Tu. The in silico results agreed with in vitro far-UV circular dichroism data on apoazurin and cytochrome c. We conclude that chemical and thermal unfolding processes correlate in terms of thermodynamics and structural ensembles at most conditions; however, deviations were found at high concentrations of denaturant.

  20. Combined Ultrasonic Elliptical Vibration and Chemical Mechanical Polishing of Monocrystalline Silicon

    Directory of Open Access Journals (Sweden)

    Liu Defu

    2016-01-01

    Full Text Available An ultrasonic elliptical vibration assisted chemical mechanical polishing(UEV-CMP is employed to achieve high material removal rate and high surface quality in the finishing of hard and brittle materials such as monocrystalline silicon, which combines the functions of conventional CMP and ultrasonic machining. In theultrasonic elliptical vibration aided chemical mechanical polishingexperimental setup developed by ourselves, the workpiece attached at the end of horn can vibrate simultaneously in both horizontal and vertical directions. Polishing experiments are carried out involving monocrystalline silicon to confirm the performance of the proposed UEV-CMP. The experimental results reveal that the ultrasonic elliptical vibration can increase significantly the material removal rate and reduce dramatically the surface roughness of monocrystalline silicon. It is found that the removal rate of monocrystalline silicon polished by UEV-CMP is increased by approximately 110% relative to that of conventional CMP because a passive layer on the monocrystalline silicon surface, formed by the chemical action of the polishing slurry, will be removed not only by the mechanical action of CMP but also by ultrasonic vibration action. It indicates that the high efficiency and high quality CMP of monocrystalline silicon can be performed with the proposed UEV-CMP technique.

  1. Efficient and selective chemical transformations under flow conditions: The combination of supported catalysts and supercritical fluids

    Directory of Open Access Journals (Sweden)

    M. Isabel Burguete

    2011-09-01

    Full Text Available This paper reviews the current trends in the combined use of supported catalytic systems, either on solid supports or in liquid phases and supercritical fluids (scFs, to develop selective and enantioselective chemical transformations under continuous and semi-continuous flow conditions. The results presented have been selected to highlight how the combined use of those two elements can contribute to: (i Significant improvements in productivity as a result of the enhanced diffusion of substrates and reagents through the interfaces favored by the scF phase; (ii the long term stability of the catalytic systems, which also contributes to the improvement of the final productivity, as the use of an appropriate immobilization strategy facilitates catalyst isolation and reuse; (iii the development of highly efficient selective or, when applicable, enantioselective chemical transformations. Although the examples reported in the literature and considered in this review are currently confined to a limited number of fields, a significant development in this area can be envisaged for the near future due to the clear advantages of these systems over the conventional ones.

  2. Chemical characteristics of grape juices from different cultivar and rootstock combinations

    Directory of Open Access Journals (Sweden)

    Rita de Cássia Mirela Resende Nassur

    2014-07-01

    Full Text Available The objective of this work was to evaluate the influence of different combinations of grape cultivars and rootstocks on chemical characteristics of grape juices. Six treatments were evaluated, consisting of combinations between the Isabel Precoce and BRS Cora grape cultivars and the 'IAC 766', 'IAC 313', and 'IAC 572' rootstocks. Approximately 10 L of juice were obtained per treatment. Analyses of color, total soluble solids content, pH, anthocyanins, total phenolics, total sugars, and quantification and identification of biogenic amines by HPLC were performed. Biogenic amines, such as putrescine, cadaverine, spermidine, and spermine, were found in all evaluated cultivars. By principal component analysis (PCA, treatments can be divided into two groups, according to the cultivar. Juices obtained from 'Isabel Precoce' are characterized by higher levels of total sugar content and soluble solids; however, juices from 'BRS Cora' are positively correlated with phenolic content, anthocyanins, and color and acidity parameters. The differences found by PCA for juices from the Isabel Precoce and BRS Cora cultivars indicate that, regardless of the rootstock used, the most important factor in the chemical characterization of juices is the grape cultivar.

  3. Comparative Studies on Methane Upgradation of Biogas by Removing of Contaminant Gases Using Combined Chemical Methods

    Directory of Open Access Journals (Sweden)

    Muhammad Rashed Al Mamun

    2015-07-01

    Full Text Available Biogas, which generated from renewable sources can be used as a sustainable energy to achieve resourceful targets of biofuel for internal combustion engines. This process can be achieved in combined absorption and adsorption chemical way. This method can be employed by aqueous solutions of calcium hydroxide, activated carbon, iron(II chloride, silica gel and sodium sulfate respectively. The presence of CO2, H2S and H2O in the biogas has lowering the calorific value and detrimental corrosion effects on the metal components. Removal of these contaminants from the biogas can therefore significantly improve the gas quality. A comparison study was investigated using combined chemical methods of improving the calorific value of biogas. Experiment results revealed that the aqueous solution used effectively in reacting with CO2 in biogas (over 85-90% removal efficiency, creating CH4 enriched biogas. The removal efficiency was the highest in method 1, where efficiency results were 91.5%, 97.1% and 91.8%, for CO2, H2S, and H2O, respectively. The corresponding CH4 enrichment was 97.5%. These results indicate that the method 1 is more suitable compare to method 2. However, both methane enrichment processes might be useful for cleaning and upgrading methane quality in biogas.

  4. Preparation,inentification and application of pyrenebutyric acid-silica and diphenylanthracene-silica reagent on fiber-optic chemical sensor

    Institute of Scientific and Technical Information of China (English)

    LI Xin-xia; CHEN Jian

    2003-01-01

    @@ 1 Introduction Two new fiber-optic chemical sensor based on multiple fluorescence quenching is described. The reagent phases of the sensors are stable in organic solvent. The first reagent phase was constructed by covalent bonding pyrenebutyric acid (PBA) to the surface of glass (PBA-SiO2). It was identified by IR spectrum, fluorescence spectra and TGA analysis. And it can determine Rutin in ethanol.

  5. A Method for Integrating ZnO Coated Nanosprings into a Low Cost Redox-Based Chemical Sensor and Catalytic Tool for Determining Gas Phase Reaction Kinetics

    Directory of Open Access Journals (Sweden)

    Pavel V. Bakharev

    2014-01-01

    Full Text Available A chemical sensor (chemiresistor was constructed from a xenon light bulb by coating it with a 3-D zinc oxide coated silica nanospring mat, where the xenon light bulb serves as the sensor heater. The sensor response to toluene as a function of xenon light bulb sensor temperature (TLB and vapor temperature (TV was observed and analyzed. The optimum operational parameters in terms of TLB and TV were determined to be 435 °C and 250 °C, respectively. The activation energy of toluene oxidation (Ed on the ZnO surface was determined to be 87 kJ·mol−1, while the activation energy of oxidation (Ea of the depleted ZnO surface was determined to be 83 kJ·mol−1. This study serves as proof of principle for integrating nanomaterials into an inexpensive sensor platform, which can also be used to characterize gas-solid, or vapor-solid, redox processes.

  6. Toward the Realization of a Compact Chemical Sensor Platform using Quantum Cascade Lasers

    Science.gov (United States)

    2015-09-01

    tunable QCL with a MEMS-scale photoacoustic cell produces favorable detection limits ( ppb levels) for chemical targets (e.g., dimethyl methyl...MEMS-scale photoacoustic cell produces favorable detection limits ( ppb levels) for chemical targets (e.g., dimethyl methyl phosphonate (DMMP), vinyl... group of highly sensitive methods that can be used to detect trace levels of gases using optical absorption and subsequent thermal perturbations of

  7. Design, Fabrication, Processing, and Testing of Micro-Electro-Mechanical Chemical Sensors

    Science.gov (United States)

    1995-12-01

    3.2.2 Electrostatic Theory. .. .. .. .. ... ... ... .... .. 48 3.2.3 Capacitance . .. .. .. .. ... ... .... ... ... .... 50 3.3 Chemical Transport Theory...available to heat the thin film coating, effecting both an intrinsic conductivity change due to the semiconducting material and an extrinsic change due to...other surface-fabricated MOSFET device, except that the metal gate is replaced by an external reference electrode and is coated with a chemically

  8. Problem formulation for risk assessment of combined exposures to chemicals and other stressors in humans.

    Science.gov (United States)

    Solomon, Keith R; Wilks, Martin F; Bachman, Ammie; Boobis, Alan; Moretto, Angelo; Pastoor, Timothy P; Phillips, Richard; Embry, Michelle R

    2016-11-01

    When the human health risk assessment/risk management paradigm was developed, it did not explicitly include a "problem formulation" phase. The concept of problem formulation was first introduced in the context of ecological risk assessment (ERA) for the pragmatic reason to constrain and focus ERAs on the key questions. However, this need also exists for human health risk assessment, particularly for cumulative risk assessment (CRA), because of its complexity. CRA encompasses the combined threats to health from exposure via all relevant routes to multiple stressors, including biological, chemical, physical and psychosocial stressors. As part of the HESI Risk Assessment in the 21st Century (RISK21) Project, a framework for CRA was developed in which problem formulation plays a critical role. The focus of this effort is primarily on a chemical CRA (i.e., two or more chemicals) with subsequent consideration of non-chemical stressors, defined as "modulating factors" (ModFs). Problem formulation is a systematic approach that identifies all factors critical to a specific risk assessment and considers the purpose of the assessment, scope and depth of the necessary analysis, analytical approach, available resources and outcomes, and overall risk management goal. There are numerous considerations that are specific to multiple stressors, and proper problem formulation can help to focus a CRA to the key factors in order to optimize resources. As part of the problem formulation, conceptual models for exposures and responses can be developed that address these factors, such as temporal relationships between stressors and consideration of the appropriate ModFs.

  9. Introductory lecture: atmospheric organic aerosols: insights from the combination of measurements and chemical transport models.

    Science.gov (United States)

    Pandis, Spyros N; Donahue, Neil M; Murphy, Benjamin N; Riipinen, Ilona; Fountoukis, Christos; Karnezi, Eleni; Patoulias, David; Skyllakou, Ksakousti

    2013-01-01

    The formation, atmospheric evolution, properties, and removal of organic particulate matter remain some of the least understood aspects of atmospheric chemistry despite the importance of organic aerosol (OA) for both human health and climate change. Here, we summarize our recent efforts to deal with the chemical complexity of the tens of thousands of organic compounds in the atmosphere using the volatility-oxygen content framework (often called the 2D-Volatility Basis Set, 2D-VBS). Our current ability to measure the ambient OA concentration as a function of its volatility and oxygen to carbon (O:C) ratio is evaluated. The combination of a thermodenuder, isothermal dilution and Aerosol Mass Spectrometry (AMS) together with a mathematical aerosol dynamics model is a promising approach. The development of computational modules based on the 2D-VBS that can be used in chemical transport models (CTMs) is described. Approaches of different complexity are tested against ambient observations, showing the challenge of simulating the complex chemical evolution of atmospheric OA. The results of the simplest approach describing the net change due to functionalization and fragmentation are quite encouraging, reproducing both the observed OA levels and O : C in a variety of conditions. The same CTM coupled with source-apportionment algorithms can be used to gain insights into the travel distances and age of atmospheric OA. We estimate that the average age of OA near the ground in continental locations is 1-2 days and most of it was emitted (either as precursor vapors or particles) hundreds of kilometers away. Condensation of organic vapors on fresh particles is critical for the growth of these new particles to larger sizes and eventually to cloud condensation nuclei (CCN) sizes. The semivolatile organics currently simulated by CTMs are too volatile to condense on these tiny particles with high curvature. We show that chemical aging reactions converting these semivolatile

  10. Combined Geometric and Neural Network Approach to Generic Fault Diagnosis in Satellite Actuators and Sensors

    DEFF Research Database (Denmark)

    Baldi, P.; Blanke, Mogens; Castaldi, P.;

    2016-01-01

    This paper presents a novel scheme for diagnosis of faults affecting the sensors measuring the satellite attitude, body angular velocity and flywheel spin rates as well as defects related to the control torques provided by satellite reaction wheels. A nonlinear geometric design is used to avoid...... that aerodynamic disturbance torques have unwanted influence on the residuals exploited for fault detection and isolation. Radial basis function neural networks are used to obtain fault estimation filters that do not need a priori information about the fault internal models. Simulation results are based...... on a detailed nonlinear satellite model with embedded disturbance description. The results document the efficacy of the proposed diagnosis scheme....

  11. Cross-Layer Protocol Combining Tree Routing and TDMA Slotting in Wireless Sensor Networks

    Science.gov (United States)

    Bai, Ronggang; Ji, Yusheng; Lin, Zhiting; Wang, Qinghua; Zhou, Xiaofang; Qu, Yugui; Zhao, Baohua

    Being different from other networks, the load and direction of data traffic for wireless sensor networks are rather predictable. The relationships between nodes are cooperative rather than competitive. These features allow the design approach of a protocol stack to be able to use the cross-layer interactive way instead of a hierarchical structure. The proposed cross-layer protocol CLWSN optimizes the channel allocation in the MAC layer using the information from the routing tables, reduces the conflicting set, and improves the throughput. Simulations revealed that it outperforms SMAC and MINA in terms of delay and energy consumption.

  12. Combined physico-chemical treatment of secondary settled municipal wastewater in a multifunctional reactor.

    Science.gov (United States)

    Santoro, O; Pastore, T; Santoro, D; Crapulli, F; Raisee, M; Moghaddami, M

    2013-01-01

    In this paper, the physico-chemical treatment of municipal wastewater for the simultaneous removal of pollutant indicators (chemical oxygen demand (COD) and total coliforms) and organic contaminants (total phenols) was investigated and assessed. A secondary settled effluent was subjected to coagulation, disinfection and absorption in a multifunctional reactor by dosing, simultaneously, aluminum polychloride (dose range: 0-150 μL/L), natural zeolites (dose range: 0-150 mg/L), sodium hypochlorite (dose range: 0-7.5 mg/L) and powder activated carbon (dose range: 0-30 mg/L). The treatment process was optimized using computational fluid dynamics (CFD) and response surface methodology. Specifically, a Latin square technique was employed to generate 16 combinations of treating agent types and concentrations which were pilot tested on an 8 m(3)/h multifunctional reactor fed by a secondary effluent with COD and total coliform concentrations ranging from ≈20 to 120 mg/L and from 10(5) to 10(6) CFU/100 mL, respectively. Results were promising, indicating that removal yields up to 71% in COD and 5.4 log in total coliforms were obtained using an optimal combination of aluminum polychloride (dose range ≈ 84-106 μL/L), powder activated carbon ≈ 5 mg/L, natural zeolite (dose range ≈ 34-70 mg/L) and sodium hypochlorite (dose range ≈ 3.4-5.6 mg/L), with all treating agents playing a statistically significant role in determining the overall treatment performance. Remarkably, the combined process was also able to remove ≈ 50% of total phenols, a micropollutant known to be recalcitrant to conventional wastewater treatments.

  13. [HEALTH STATUS OF ELECTROTECHNICAL PERSONNEL EXPOSED TO THE COMBINED IMPACT OF ELECTROMAGNETIC FIELDS OF 50 HZ AND CHEMICALS].

    Science.gov (United States)

    Rusin, M N; Amirov, N Kh; Sibgatullin, A S; Krasnoshchekova, V N

    2015-01-01

    There was performed an analysis of the working conditions and health status of workers of the chemical enterprise. In male electrical staff exposed to electromagnetic fields (EMF) of 50 Hz and chemicals, according to data of periodic medical examinations there was revealed statistically higher incidence of cardiovascular diseases and autonomic disorders. The obtained preliminary results allow to suggest the upsurge of the involvement of the autonomic nervous system in response to the combined effects of EMF of 50 Hz and chemicals.

  14. Time-domain fiber loop ringdown sensor and sensor network

    Science.gov (United States)

    Kaya, Malik

    Optical fibers have been mostly used in fiber optic communications, imaging optics, sensing technology, etc. Fiber optic sensors have gained increasing attention for scientific and structural health monitoring (SHM) applications. In this study, fiber loop ringdown (FLRD) sensors were fabricated for scientific, SHM, and sensor networking applications. FLRD biosensors were fabricated for both bulk refractive index (RI)- and surface RI-based DNA sensing and one type of bacteria sensing. Furthermore, the effect of glucose oxidase (GOD) immobilization at the sensor head on sensor performance was evaluated for both glucose and synthetic urine solutions with glucose concentration between 0.1% and 10%. Detection sensitivities of the glucose sensors were achieved as low as 0.05%. For chemical sensing, heavy water, ranging from 97% to 10%, and several elemental solutions were monitored by using the FLRD chemical sensors. Bulk index-based FLRD sensing showed that trace elements can be detected in deionized water. For physical sensing, water and cracking sensors were fabricated and embedded into concrete. A partially-etched single-mode fiber (SMF) was embedded into a concrete bar for water monitoring while a bare SMF without any treatment was directly embedded into another concrete bar for monitoring cracks. Furthermore, detection sensitivities of water and crack sensors were investigated as 10 ml water and 0.5 mm surface crack width, respectively. Additionally fiber loop ringdown-fiber Bragg grating temperature sensors were developed in the laboratory; two sensor units for water, crack, and temperature sensing were deployed into a concrete cube in a US Department of Energy test bed (Miami, FL). Multi-sensor applications in a real concrete structure were accomplished by testing the six FLRD sensors. As a final stage, a sensor network was assembled by multiplexing two or three FLRD sensors in series and parallel. Additionally, two FLRD sensors were combined in series and

  15. CRIM-TRACK: sensor system for detection of criminal chemical substances

    Science.gov (United States)

    Munk, Jens K.; Buus, Ole T.; Larsen, Jan; Dossi, Eleftheria; Tatlow, Sol; Lässig, Lina; Sandström, Lars; Jakobsen, Mogens H.

    2015-10-01

    Detection of illegal compounds requires a reliable, selective and sensitive detection device. The successful device features automated target acquisition, identification and signal processing. It is portable, fast, user friendly, sensitive, specific, and cost efficient. LEAs are in need of such technology. CRIM-TRACK is developing a sensing device based on these requirements. We engage highly skilled specialists from research institutions, industry, SMEs and LEAs and rely on a team of end users to benefit maximally from our prototypes. Currently we can detect minute quantities of drugs, explosives and precursors thereof in laboratory settings. Using colorimetric technology we have developed prototypes that employ disposable sensing chips. Ease of operation and intuitive sensor response are highly prioritized features that we implement as we gather data to feed into machine learning. With machine learning our ability to detect threat compounds amidst harmless substances improves. Different end users prefer their equipment optimized for their specific field. In an explosives-detecting scenario, the end user may prefer false positives over false negatives, while the opposite may be true in a drug-detecting scenario. Such decisions will be programmed to match user preference. Sensor output can be as detailed as the sensor allows. The user can be informed of the statistics behind the detection, identities of all detected substances, and quantities thereof. The response can also be simplified to "yes" vs. "no". The technology under development in CRIM-TRACK will provide custom officers, police and other authorities with an effective tool to control trafficking of illegal drugs and drug precursors.

  16. Combining Chemical Information Literacy, Communication Skills, Career Preparation, Ethics, and Peer Review in a Team-Taught Chemistry Course

    Science.gov (United States)

    Jones, Mary Lou Baker; Seybold, Paul G.

    2016-01-01

    The widely acknowledged need to include chemical information competencies and communication skills in the undergraduate chemistry curriculum can be accommodated in a variety of ways. We describe a team-taught, semester-length course at Wright State University which combines chemical information literacy, written and oral communication skills,…

  17. Combining Chemical Information Literacy, Communication Skills, Career Preparation, Ethics, and Peer Review in a Team-Taught Chemistry Course

    Science.gov (United States)

    Jones, Mary Lou Baker; Seybold, Paul G.

    2016-01-01

    The widely acknowledged need to include chemical information competencies and communication skills in the undergraduate chemistry curriculum can be accommodated in a variety of ways. We describe a team-taught, semester-length course at Wright State University which combines chemical information literacy, written and oral communication skills,…

  18. Chemical detection in liquid media with a refractometric sensor based on a multimode optical fibre

    OpenAIRE

    V. Matejec; Jaffrezic-Renault, N.; Abdelghani, A.; S. Hleli; Cherif, K

    2002-01-01

    In this paper the physical basis for the design of an optical fibre sensor suited for aqueous medium and gas phase based on the excitation of an evanescent wave at the core/cladding interface is developed. The detection based on the refractive index changes (between 1.41 and 1.45) of the infinite dielectric medium which can be an electrolyte or a sol-gel polymer deposited on the uncladed part of the fibre. Refractive indices of absorbent and volatile compounds such as fuel and unleaded gas we...

  19. Brain machine interfaces combining microelectrode arrays with nanostructured optical biochemical sensors

    Science.gov (United States)

    Hajj-Hassan, Mohamad; Gonzalez, Timothy; Ghafer-Zadeh, Ebrahim; Chodavarapu, Vamsy; Musallam, Sam; Andrews, Mark

    2009-02-01

    Neural microelectrodes are an important component of neural prosthetic systems which assist paralyzed patients by allowing them to operate computers or robots using their neural activity. These microelectrodes are also used in clinical settings to localize the locus of seizure initiation in epilepsy or to stimulate sub-cortical structures in patients with Parkinson's disease. In neural prosthetic systems, implanted microelectrodes record the electrical potential generated by specific thoughts and relay the signals to algorithms trained to interpret these thoughts. In this paper, we describe novel elongated multi-site neural electrodes that can record electrical signals and specific neural biomarkers and that can reach depths greater than 8mm in the sulcus of non-human primates (monkeys). We hypothesize that additional signals recorded by the multimodal probes will increase the information yield when compared to standard probes that record just electropotentials. We describe integration of optical biochemical sensors with neural microelectrodes. The sensors are made using sol-gel derived xerogel thin films that encapsulate specific biomarker responsive luminophores in their nanostructured pores. The desired neural biomarkers are O2, pH, K+, and Na+ ions. As a prototype, we demonstrate direct-write patterning to create oxygen-responsive xerogel waveguide structures on the neural microelectrodes. The recording of neural biomarkers along with electrical activity could help the development of intelligent and more userfriendly neural prosthesis/brain machine interfaces as well as aid in providing answers to complex brain diseases and disorders.

  20. Synthesis of ultra-long cadmium telluride nanotubes via combinational chemical transformation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kee-Ryung; Cho, Hong-Baek; Choa, Yong-Ho, E-mail: choa15@hanyang.ac.kr

    2017-03-01

    Synthesis of high-throughput cadmium telluride (CdTe) nanotubes with an ultra-long aspect ratio is presented via a combination process concept combined with electrospinning, electrodeposition, and cationic exchange reaction. Ultra-long sacrificial silver (Ag) nanofibers were synthesized by electrospinning involving two-step calcination, and were then electrodeposited to create silver telluride nanotubes. These nanotubes underwent cationic exchange reaction in cadmium nitrate tetrahydrate solution with the aid of a ligand, tributylphosphine (TBP). Analysis showed that ultra-long pure zinc blende CdTe nanotubes were obtained with controlled dimension and uniform morphology. The thermodynamic driving force induced by the coordination of methanol solvent and TBP attributed to overcome the kinetic barrier between Ag{sub 2}Te and CdTe nanotubes, facilitating the synthesis of CdTe nanotubes. This synthetic process involving a topotactic reaction route paves a way for high-throughput extended synthesis of new chalcogenide hollow nanotubes for application in photodetectors and solar cells. - Highlights: • High throughput synthetic route of hollow CdTe nanotubes with ultra-long aspect ratio. • Chemical combination of electrospinning, electrodeposition & cation exchange reaction. • Pure zinc blende CdTe by controlled dimension & structural variation of Ag nanofibers. • Potential for the high throughput synthesis of new exotic chalcogenide nanotubes.

  1. A Method for Improving the Pose Accuracy of a Robot Manipulator Based on Multi-Sensor Combined Measurement and Data Fusion

    Science.gov (United States)

    Liu, Bailing; Zhang, Fumin; Qu, Xinghua

    2015-01-01

    An improvement method for the pose accuracy of a robot manipulator by using a multiple-sensor combination measuring system (MCMS) is presented. It is composed of a visual sensor, an angle sensor and a series robot. The visual sensor is utilized to measure the position of the manipulator in real time, and the angle sensor is rigidly attached to the manipulator to obtain its orientation. Due to the higher accuracy of the multi-sensor, two efficient data fusion approaches, the Kalman filter (KF) and multi-sensor optimal information fusion algorithm (MOIFA), are used to fuse the position and orientation of the manipulator. The simulation and experimental results show that the pose accuracy of the robot manipulator is improved dramatically by 38%∼78% with the multi-sensor data fusion. Comparing with reported pose accuracy improvement methods, the primary advantage of this method is that it does not require the complex solution of the kinematics parameter equations, increase of the motion constraints and the complicated procedures of the traditional vision-based methods. It makes the robot processing more autonomous and accurate. To improve the reliability and accuracy of the pose measurements of MCMS, the visual sensor repeatability is experimentally studied. An optimal range of 1 × 0.8 × 1 ∼ 2 × 0.8 × 1 m in the field of view (FOV) is indicated by the experimental results. PMID:25850067

  2. Innovative Strategies to Develop Chemical Categories Using a Combination of Structural and Toxicological Properties

    Directory of Open Access Journals (Sweden)

    Monika Batke

    2016-09-01

    Full Text Available 1.AbstractInterest is increasing in the development of non-animal methods for toxicological evaluations. These methods are however, particularly challenging for complex toxicological endpoints such as repeated dose toxicity. European Legislation, e.g. the European Union´s Cosmetic Directive and REACH, demands the use of alternative methods. Frameworks, such as the Read-across Assessment Framework or the Adverse Outcome Pathway Knowledge Base, support the development of these methods. The aim of the project presented in this publication was to develop substance categories for a read-across with complex endpoints of toxicity based on existing databases. The basic conceptual approach was to combine structural similarity with shared mechanisms of action. Substances with similar chemical structure and toxicological profile form candidate categories suitable for read-across. We combined two databases on repeated dose toxicity, RepDose database and ELINCS database to form a common database for the identification of categories. The resulting database contained physicochemical, structural and toxicological data, which were refined and curated for cluster analyses. We applied the Predictive Clustering Tree (PCT approach for clustering chemicals based on structural and on toxicological information to detect groups of chemicals with similar toxic profiles and pathways/mechanisms of toxicity. As many of the experimental toxicity values were not available, this data was imputed by predicting them with a multi-label classification method, prior to clustering. The clustering results were evaluated by assessing chemical and toxicological similarities with the aim of identifying clusters with a concordance between structural information and toxicity profiles/mechanisms. From these chosen clusters, seven were selected for a quantitative read-across, based on a small ratio of NOAEL of the members with the highest and the lowest NOAEL in the cluster (<5. We discuss

  3. An optical chemical sensor for thorium (IV) determination based on thorin.

    Science.gov (United States)

    Rastegarzadeh, S; Pourreza, N; Saeedi, I

    2010-01-15

    A selective method for the determination of thorium (IV) using an optical sensor is described. The sensing membrane is prepared by immobilization of thorin-methyltrioctylammonium ion pair on triacetylcellulose polymer. The sensor produced a linear response for thorium (IV) concentration in the range of 6.46 x 10(-6) to 9.91 x 10(-5)mol L(-1) with detection limit of 1.85 x 10(-6)mol L(-1). The regeneration of optode was accomplished completely at a short time (less than 20s) with 0.1 mol L(-1) of oxalate ion solution. The relative standard deviation for ten replicate measurements of 2.15 x 10(-5) and 8.62 x 10(-5)mol L(-1) of thorium was 2.71 and 1.65%, respectively. The optode membrane exhibits good selectivity for thorium (IV) over several other ionic species and are comparable to those obtained in case of spectrophotometric determination of thorium using thorin in solution. A good agreement with the ICP-MS and spiked method was achieved when the proposed optode was applied to the determination of thorium (IV) in dust and water samples.

  4. Chemically synthesized PbS Nano particulate thin films for a rapid NO2 gas sensor

    Directory of Open Access Journals (Sweden)

    Burungale Vishal V.

    2016-03-01

    Full Text Available Rapid NO2 gas sensor has been developed based on PbS nanoparticulate thin films synthesized by Successive Ionic Layer Adsorption and Reaction (SILAR method at different precursor concentrations. The structural and morphological properties were investigated by means of X-ray diffraction and field emission scanning electron microscope. NO2 gas sensing properties of PbS thin films deposited at different concentrations were tested. PbS film with 0.25 M precursor concentration showed the highest sensitivity. In order to optimize the operating temperature, the sensitivity of the sensor to 50 ppm NO2 gas was measured at different operating temperatures, from 50 to 200 °C. The gas sensitivity increased with an increase in operating temperature and achieved the maximum value at 150 °C, followed by a decrease in sensitivity with further increase of the operating temperature. The sensitivity was about 35 % for 50 ppm NO2 at 150 °C with rapid response time of 6 s. T90 and T10 recovery time was 97 s at this gas concentration.

  5. Towards outperforming conventional sensor arrays with fabricated individual photonic vapour sensors inspired by Morpho butterflies

    Science.gov (United States)

    Potyrailo, Radislav A.; Bonam, Ravi K.; Hartley, John G.; Starkey, Timothy A.; Vukusic, Peter; Vasudev, Milana; Bunning, Timothy; Naik, Rajesh R.; Tang, Zhexiong; Palacios, Manuel A.; Larsen, Michael; Le Tarte, Laurie A.; Grande, James C.; Zhong, Sheng; Deng, Tao

    2015-09-01

    Combining vapour sensors into arrays is an accepted compromise to mitigate poor selectivity of conventional sensors. Here we show individual nanofabricated sensors that not only selectively detect separate vapours in pristine conditions but also quantify these vapours in mixtures, and when blended with a variable moisture background. Our sensor design is inspired by the iridescent nanostructure and gradient surface chemistry of Morpho butterflies and involves physical and chemical design criteria. The physical design involves optical interference and diffraction on the fabricated periodic nanostructures and uses optical loss in the nanostructure to enhance the spectral diversity of reflectance. The chemical design uses spatially controlled nanostructure functionalization. Thus, while quantitation of analytes in the presence of variable backgrounds is challenging for most sensor arrays, we achieve this goal using individual multivariable sensors. These colorimetric sensors can be tuned for numerous vapour sensing scenarios in confined areas or as individual nodes for distributed monitoring.

  6. Chemical etching of Tungsten thin films for high-temperature surface acoustic wave-based sensor devices

    Energy Technology Data Exchange (ETDEWEB)

    Spindler, M., E-mail: m.spindler@ifw-dresden.de [IFW Dresden, SAWLab Saxony, P.O. Box 270116, D-01171 Dresden (Germany); Herold, S.; Acker, J. [BTU Cottbus – Senftenberg, Faculty of Sciences, P.O. Box 101548, 01968 Senftenberg (Germany); Brachmann, E.; Oswald, S.; Menzel, S.; Rane, G. [IFW Dresden, SAWLab Saxony, P.O. Box 270116, D-01171 Dresden (Germany)

    2016-08-01

    Surface acoustic wave devices are widely used as wireless sensors in different application fields. Recent developments aimed to utilize those devices as temperature sensors even in the high temperature range (T > 300 °C) and in harsh environmental conditions. Therefore, conventional materials, which are used for the substrate and for the interdigital transducer finger electrodes such as multilayers or alloys based on Al or Cu have to be exchanged by materials, which fulfill some important criteria regarding temperature related effects. Electron beam evaporation as a standard fabrication method is not well applicable for depositing high temperature stable electrode materials because of their very high melting points. Magnetron sputtering is an alternative deposition process but is also not applicable for lift-off structuring without any further improvement of the structuring process. Due to a relatively high Ar gas pressure of about 10{sup −1} Pa, the sidewalls of the photoresist line structures are also covered by the metallization, which subsequently prevents a successful lift-off process. In this study, we investigate the chemical etching of thin tungsten films as an intermediate step between magnetron sputtering deposition of thin tungsten finger electrodes and the lift-off process to remove sidewall covering for a successful patterning process of interdigital transducers. - Highlights: • We fabricated Tungsten SAW Electrodes by magnetron sputtering technology. • An etching process removes sidewall covering of photoresist, which allows lift-off. • Tungsten etching rates based on a hydrogen peroxide solutions were determined.

  7. Sensitive and fast response ethanol chemical sensor based on as-grown Gd2O3 nanostructures

    Institute of Scientific and Technical Information of China (English)

    MM Abdullah; Mohammed M Rahman; Houcine Bouzid; M Faisal; Sher Bahadar Khan; SA Al-Sayari; Adel A Ismail

    2015-01-01

    Well crystalline gadolinium oxide (Gd2O3) nanostructures were grown by annealing the hydrothermally as-prepared nanostructures without using any template. Microscopic studies of Gd2O3 nanostructures were recorded along the [111] direction due to the clearly resolved interplanar distance d(222)~0.31 nm of the cubic crystal structure Gd2O3. Sensing mechanism of Gd2O3 as efficient electron mediator for the detection of ethanol was explored. As-fabricated sensor demonstrated the high-sensitivity of~0.266 µAm/M/cm2 with low detection limit (~52.2 µmol/L) and correlation coefficient (r2, 0.618). To the best of our knowledge, this was the first report for the detection of ethanol using as-grown (at 1000 ºC) Gd2O3 nanostructures by simple and reliable I-V technique and rapid assessment of the reaction kinetics (in the order of seconds). The low cost of the starting reagents and the simplicity of the synthetic route made it a promising chemical sensor for the detection of various toxic analytes, which are not en-vironmentally safe.

  8. A miniature photoelectrochemical sensor based on organic electrochemical transistor for sensitive determination of chemical oxygen demand in wastewaters.

    Science.gov (United States)

    Liao, Jianjun; Lin, Shiwei; Zeng, Min; Yang, Yue

    2016-05-01

    A three-electrode configuration is often required in the conventional photoelectrochemical measurements. Nevertheless, one common drawback is the reference electrode and the counter electrode used in the measurements, which has been proved to be an impediment for the miniaturization. In this study, a simple, cost-effective and miniature photoelectrochemical sensor based on high sensitive organic electrochemical transistor (OECT) is developed and used for the determination of chemical oxygen demand (COD) in wastewaters. The devices show detection limit down to 0.01 mg/L COD, which is two orders of magnitude better than that of the conventional photoelectrochemical method. The excellent sensing performance can be contributed to the novel sensing mechanism of OECT devices. That is, the devices are sensitive to the potential changes induced by the photoelectrochemical reaction on TiO2 nanotube arrays gate electrodes. Real sample analyses are also carried out. The results demonstrate that the measured COD values using the OECT devices and the standard dichromate methods are in a good agreement. Since the proposed sensor is constructed on a miniature transistor, it is expected that the device shows a promising application on the integrated COD monitoring platform.

  9. Coupled determination of gravimetric and elastic effects on two resonant chemical sensors: love wave and microcantilever platforms.

    Science.gov (United States)

    Fadel, Ludivine; Zimmermann, Céline; Dufour, Isabelle; Déjous, Corinne; Rebière, Dominique; Pistré, Jacques

    2005-02-01

    The objective of this paper is to couple theoretical and experimental results from microcantilevers and Love-wave acoustic devices in order to identify and separate mass loading effects from elastic effects. This is important in the perspective of sensing applications. For that, a thin-film polymer is deposited on both resonant platforms. It is demonstrated that microcantilevers are essentially mass sensitive. They allow one to determine the polymer layer thickness, which is validated by optical profilometry measurements. Then, taking into account this thickness, theoretical modeling and experimental measurements with Love-wave devices permit one to estimate an equivalent elastic shear modulus of the thin-film polymer at high frequency. Results are interesting if one is to fully understand and optimize (bio)chemical sensor responses.

  10. Development of a Novel Fiber Optic Sensor Combined with a Fluorescence Turn-on Probe for Cu (II Detection

    Directory of Open Access Journals (Sweden)

    Ma J.

    2013-04-01

    Full Text Available Existing staining-based methodology for the detection of metal ions is not well suited for real-time or in situ use. This is a significant problem, given that these ions can have a considerable impact on both human health and the environment. Thus, there is growing interest and need for simple, rapid and in-situ monitoring techniques for the purpose of detecting various target analytes (e.g. heavy metals, which is of a significant importance in many fields ranging from environmental monitoring to the study of intracellular processes. Among various sensors developed, optical fiber-optic sensors (FOS, based on fluorescence, are one class of sensors that address this goal [1]. Optical fibers are ideal for environmental sensing applications because of their ability to transmit optical signals to and from the sensing region without the use of free-space optics. In this work, we present, for the first time, a simple FOS incorporating novel fluorescence turn-on mechanism [2] that could detect Cu (II as low as 10−4 M. Traditionally, fluorescence quenching or “turn-off” was used to detect Cu (II [3]. In recent years, fluorescence “turn-on” emerges as a preferable tool. The developed fiber-optic sensor has two fiber leads and one probe head. One fiber lead includes 6 fibers for He-Ne laser excitation light delivery (e-fibers. Another fiber lead has one receiving fiber (r-fiber connected to an Ocean Optics QE65000 scientific grade spectrometer, which is interrogated by a computer via USB connection. The SpectroSuite software is used to observe and to record all spectra. The probe head combines all fibers together to form a coaxial structure with the r-fiber placed in the center. The key component in the proposed fluorescent sensing system is a probe prepared by binding a receptor containing a zwitterionic chromophore (M1, through noncovalent interactions, to the fluorescent polymer (P1 resulting in quenching its emission. The sensing mechanism

  11. Submicrometer fiber-optic chemical sensors: Measuring pH inside single cells. Progress report, October 1990--August 1993

    Energy Technology Data Exchange (ETDEWEB)

    Kopelman, R.

    1993-12-01

    Starting from scratch, we went in two and a half years to 0.04 micron optical microscopy resolution. We have demonstrated the application of near-field scanning optical microscopy to DNA samples and opened the new fields of near-field scanning spectroscopy and submicron opto- chemical sensors. All of these developments have been important steps towards in-situ DNA imaging and characterization on the nanoscale. Our first goal was to make NSOM (near-field scanning optical microscopy) a working enterprise, capable of ``zooming-in`` towards a sample and imaging with a resolution exceeding that of traditional microscopy by a factor of ten. This has been achieved. Not only do we have a resolution of about 40 nm but we can image a 1 {times} 1 micron object in less than 10 seconds. Furthermore, the NSOM is a practical instrument. The tips survive for days or weeks of scanning and new methods of force feedback will soon protect the most fragile samples. Reproducible images of metal gratings, gold particles, dye balls (for calibration) and of several DNA samples have been made, proving the practicality of our approach. We also give highly resolved Force/NSOM images of human blood cells. Our second goal has been to form molecular optics (e.g., exciton donor) tips with a resolution of 2--10 nm for molecular excitation microscopy (MEM). We have produced such tips, and scanned with them, but only with a resolution comparable to that of our standard NSOM tips. However, we have demonstrated their potential for high resolution imaging capabilities: (1) An energy transfer (tip to sample) based feedback capability. (2) A Kasha (external heavy atom) effect based feedback. In addition, a novel and practical opto-chemical sensor that is a billion times smaller than the best ones available has been developed as well. Finally, we have also performed spatially resolved fluorescence spectroscopy.

  12. 高灵敏共轭聚合物化学传感器%Conjugated Polymers for Sensitive Chemical Sensors

    Institute of Scientific and Technical Information of China (English)

    朱春雷; 杨琼; 刘礼兵; 王树

    2011-01-01

    The detections of metal ion and chemical small molecule are of great importance in view of their influences on human health,environment pollution,and food safety.Thus,considerable researches have been conducted toward designing and developing highly sensitive chemical sensors.In the past few decades,due to the superior electrical properties,conjugated polymers (CPs) have aroused great attentions and numerous revolutionary advances have emerged.More recently,facilitated by their signalamplifying response to sensing events,the possibility of CPs to be used as fluorescent probes toward designing novel chemical and biological sensors have been exploited.This mini account highlights the recent progress of CPs in our group for the detection of metal ion and chemical small molecule based on fluorescence technique.Three different signal transduction mechanisms,including electron transfer,fluorescence resonance energy transfer(FRET) and analyteinduced aggregation or conformational change,are involved in this account and concretely elaborated with corresponding examples.Finally,challenges confronted by CPs and their future directions are discussed.%金属离子和化学小分子的检测在人类健康、环境污染以及食品安全等领域具有重要意义,科学工作者们已经在设计、发展高灵敏化学传感器方面进行了大量研究。在过去的几十年里,共轭聚合物由于其卓越的光电性质,引起了人们极大的关注,并取得了众多革命性科技进展。最近,利用共轭聚合物的荧光信号放大机制,人们设计、发展了一系列新型的化学和生物传感体系。共轭聚合物的信号传感机制包括电子转移,荧光共振能量转移以及共轭聚合物聚集或构象改变。本文主要介绍我们实验室在利用共轭聚合物实现金属离子和化学小分子荧光检测方面取得的进展,并对未来发展方向与面临的挑战进行了讨论。

  13. Field testing of different chemical combinations as odour baits for trapping wild mosquitoes in The Gambia.

    Directory of Open Access Journals (Sweden)

    Musa Jawara

    Full Text Available Odour baited traps have potential use in population surveillance of insect vectors of disease, and in some cases for vector population reduction. Established attractants for human host-seeking mosquitoes include a combination of CO(2 with L-lactic acid and ammonia, on top of which additional candidate compounds are being tested. In this field study in rural Gambia, using Latin square experiments with thorough randomization and replication, we tested nine different leading candidate combinations of chemical odorants for attractiveness to wild mosquitoes including anthropophilic malaria vectors, using modified Mosquito Magnet-X (MM-X counterflow traps outside experimental huts containing male human sleepers. Highest catches of female mosquitoes, particularly of An. gambiae s.l. and Mansonia species, were obtained by incorporation of tetradecanoic acid. As additional carboxylic acids did not increase the trap catches further, this 'reference blend' (tetradecanoic acid with L-lactic acid, ammonia and CO(2 was used in subsequent experiments. MM-X traps with this blend caught similar numbers of An. gambiae s.l. and slightly more Mansonia and Culex mosquitoes than a standard CDC light trap, and these numbers were not significantly affected by the presence or absence of human sleepers in the huts. Experiments with CO(2 produced from overnight yeast cultures showed that this organic source was effective in enabling trap attractiveness for all mosquito species, although at a slightly lower efficiency than obtained with use of CO(2 gas cylinders. Although further studies are needed to discover additional chemicals that increase attractiveness, as well as to optimise trap design and CO(2 source for broader practical use, the odour-baited traps described here are safe and effective for sampling host-seeking mosquitoes outdoors and can be incorporated into studies of malaria vector ecology.

  14. Combined physical-chemical and biological treatment of poorly biodegradable industrial effluents.

    Science.gov (United States)

    González, Patricia; Zaror, Claudio; Carrasco, Virginia; Mondaca, Maria Angelica; Mansilla, Hector

    2003-01-01

    Effluents from small and medium sized chemical plants may contain significant amounts of poorly biodegradable aromatic compounds, which could negatively affect water quality and public health. This is a key environmental issue, particularly in areas where effluents are discharged into drinking water sources. Unfortunately, conventional biological treatment may not be able to meet discharge standards, and combined systems should be implemented. In this context, this paper presents experimental results on the application of a combined sequential ozonation-activated carbon-biological system to treat effluents containing chlorinated aromatic contaminants from chlorine based pulp bleaching. The experimental system consisted of an ozone bubble column reactor (0.3 dm3), an activated carbon fixed bed reactor (0.2 dm3), and an aerobic bioreactor (20 dm3). Ozone was produced from pure O2 using a generator rated at 2 mmol O3 h(-1). The bleaching effluent was pretreated and fed into the aerated sequencing batch bioreactor containing preconditioned biological sludge (3-4 g VSS dm(-3)), and cultured for 24 h. Samples of raw and treated effluents were assayed for biochemical oxygen demand (BOD5), chemical oxygen demand (COD), total organic carbon (TOC), total phenols, and adsorbable organic halogens (AOX), using standard techniques. The presence of potential genotoxic activity in untreated and treated samples was assessed using the Ames tests. Results show that biological treatment of raw samples could not remove mutagenic activity on its own. On the other hand, ozonation followed by activated carbon treatment and biological treatment successfully removed genotoxicity in all cases. Reductions in BOD, COD, TOC, AOX, and phenols by biological treatment increased when samples were pretreated with ozone/activated carbon.

  15. Combined physical-chemical and aerobic biological treatments of wastewater derived from sauce manufacturing.

    Science.gov (United States)

    Martín, M A; González, I; Siles, J A; Berrios, M; Martín, A

    2013-04-01

    The viability of an integrated coagulation-flocculation and aerobic treatment for purifying wastewater derived from a sauce manufacturing industry was evaluated. The best coagulation-flocculation results were obtained at alkaline pH, showing the greatest turbidity removal efficiency (greater than 90%) and a total chemical oxygen demand (COD) removal of approximately 80%, Additionally, experiments at alkaline pH reduce the reagent requirements (coagulant concentration of 0.4 mL/L and flocculant concentration of 4.0 mL/L) providing a consequent economic benefit as compared to experiments at neutral and acidic pH. Another set of experiments was conducted in a sequencing batch reactor to evaluate the aerobic biodegradability of the remnant dissolved organic matter. The effluent from the physical-chemical pre-treatment at alkaline pH again showed the highest biodegradability (76%), with a global COD total removal of 98%. The results showed that the combination of both techniques could be a viable alternative to efficiently treat wastewater derived from sauce manufacturing.

  16. Ni(II immobilization by bio-apatite materials: Appraisal of chemical, thermal and combined treatments

    Directory of Open Access Journals (Sweden)

    Šljivić-Ivanović Marija

    2016-01-01

    Full Text Available Animal bones are natural and rich source of calcium hydroxyapatite (HAP, which was found to be a good sorbent material for heavy metals and radionuclides. Various treatments can reduce the content of bone organic phase and improve sorption properties. In this study, sorption capacities of raw bovine bones (B and samples obtained by chemical treatment with NaOH (BNaOH, by heating at 400 oC (B400 and by combined chemical and thermal treatment (BNaOH+400, were compared, using Ni(II ions as sorbates. Maximum sorption capacities increased in the order B

  17. Exploring the chemical kinetics of partially oxidized intermediates by combining experiments, theory, and kinetic modeling.

    Science.gov (United States)

    Hoyermann, Karlheinz; Mauß, Fabian; Olzmann, Matthias; Welz, Oliver; Zeuch, Thomas

    2017-07-19

    Partially oxidized intermediates play a central role in combustion and atmospheric chemistry. In this perspective, we focus on the chemical kinetics of alkoxy radicals, peroxy radicals, and Criegee intermediates, which are key species in both combustion and atmospheric environments. These reactive intermediates feature a broad spectrum of chemical diversity. Their reactivity is central to our understanding of how volatile organic compounds are degraded in the atmosphere and converted into secondary organic aerosol. Moreover, they sensitively determine ignition timing in internal combustion engines. The intention of this perspective article is to provide the reader with information about the general mechanisms of reactions initiated by addition of atomic and molecular oxygen to alkyl radicals and ozone to alkenes. We will focus on critical branching points in the subsequent reaction mechanisms and discuss them from a consistent point of view. As a first example of our integrated approach, we will show how experiment, theory, and kinetic modeling have been successfully combined in the first infrared detection of Criegee intermediates during the gas phase ozonolysis. As a second example, we will examine the ignition timing of n-heptane/air mixtures at low and intermediate temperatures. Here, we present a reduced, fuel size independent kinetic model of the complex chemistry initiated by peroxy radicals that has been successfully applied to simulate standard n-heptane combustion experiments.

  18. Synthesis of tetrapeptide Bz-RGDS-NH2 by a combination of chemical and enzymatic methods.

    Science.gov (United States)

    Huang, Yi-Bing; Cai, Yu; Yang, Sen; Wang, Hua; Hou, Rui-Zhen; Xu, Li; Xiao-Xia, Wu; Zhang, Xue-Zhong

    2006-09-18

    The tetrapeptide Bz-Arg-Gly-Asp-Ser-NH(2) (Bz-RGDS-NH(2)) was successfully synthesized by a combination of chemical and enzymatic methods in this study. Firstly, the precursor tripeptide Gly-Asp-Ser-NH(2) (GDS-NH(2)) was synthesized by a novel chemical method in four steps including chloroacetylation of l-aspartic acid, synthesis of chloroacetyl l-aspartic acid anhydride, the synthesis of ClCH(2)COAsp-SerOMe and ammonolysis of ClCH(2)COAsp-SerOMe. Secondly, lipase (PPL) was used to catalyze the formation of Bz-RGDS-NH(2) in aqueous water-miscible organic cosolvent systems using Bz-Arg-OEt as the acyl donor and GDS-NH(2) as the nucleophile. The optimum conditions were Bz-Arg-OEt 50 mM; GDS-NH(2) 400 mM; 10 degrees C, 0.1M phosphate buffer, pH 7.5; 60% DMF or 58% DMSO, PPL: 10 mg ml(-1) with the maximum yields of the tetrapeptide of 73.6% for DMF and 70.4% for DMSO, respectively. The secondary hydrolysis of the tetrapeptide product did not take place due to the absence of amidase activity of lipase.

  19. Percolation via Combined Electrostatic and Chemical Doping in Complex Oxide Films

    Science.gov (United States)

    Orth, Peter P.; Fernandes, Rafael M.; Walter, Jeff; Leighton, C.; Shklovskii, B. I.

    2017-03-01

    Stimulated by experimental advances in electrolyte gating methods, we investigate theoretically percolation in thin films of inhomogeneous complex oxides, such as La1 -xSrxCoO3 (LSCO), induced by a combination of bulk chemical and surface electrostatic doping. Using numerical and analytical methods, we identify two mechanisms that describe how bulk dopants reduce the amount of electrostatic surface charge required to reach percolation: (i) bulk-assisted surface percolation and (ii) surface-assisted bulk percolation. We show that the critical surface charge strongly depends on the film thickness when the film is close to the chemical percolation threshold. In particular, thin films can be driven across the percolation transition by modest surface charge densities. If percolation is associated with the onset of ferromagnetism, as in LSCO, we further demonstrate that the presence of critical magnetic clusters extending from the film surface into the bulk results in considerable enhancement of the saturation magnetization, with pronounced experimental consequences. These results should significantly guide experimental work seeking to verify gate-induced percolation transitions in such materials.

  20. Development of a new chemical sensor based on plasma polymerized polypyrrole films

    OpenAIRE

    2010-01-01

    La present tesis contribueix a donar una nova visió dins de l'àrea de modificació de superfícies, la qual implica la nanoestructuració de substrats fent servir la tècnica d'auto-assemblatge per a dipositar sobre aquests un polímer conductor mitjançant deposició química en fase vapor per plasma. L'ús de polímers conductors ha despertat un creixent interès en el desenvolupament de sensors químics per a l'anàlisi de gasos en aplicacions d'enginyeria electrònica. La contínua reducció de mida en a...

  1. Experimental Artifacts for Morphological Tweaking of Chemical Sensor Materials: Studies on ZnO

    Directory of Open Access Journals (Sweden)

    Ikram Ul Haq

    2012-06-01

    Full Text Available Sensing mechanisms of gases on solid structures are predominantly surface-dominated. Benign surface features in terms of small grain size, high aspect ratio, large surface area and open and connected porosity, are required to realize a successful sensor material. Such morphological artifacts are a function of the fabrication and processing techniques employed. In this paper, we describe the fabrication of monoshaped and monosized zinc oxide (ZnO particles by a homogeneous precipitation method, using urea and/or hexmethyltetraamine as the reductant. The effect of operating conditions and experimental variables, such as the relative concentration of the precursors, temperature, and the aging time on the morphology of the resulting particles was studied systematically. These experimental parameters were optimized in order to achieve particles of uniform morphology and of narrow size distribution. Some of these particles were employed for the detection of ammonia gas at room temperature.

  2. Chemical detection in liquid media with a refractometric sensor based on a multimode optical fibre

    Directory of Open Access Journals (Sweden)

    V. Matejec

    2002-06-01

    Full Text Available In this paper the physical basis for the design of an optical fibre sensor suited for aqueous medium and gas phase based on the excitation of an evanescent wave at the core/cladding interface is developed. The detection based on the refractive index changes (between 1.41 and 1.45 of the infinite dielectric medium which can be an electrolyte or a sol-gel polymer deposited on the uncladed part of the fibre. Refractive indices of absorbent and volatile compounds such as fuel and unleaded gas were determined. Using a xerogel sensing layer as optical cladding, toluene detection in water was performed. The observed sensitivity is linear and the detection limit is 1% (in volume toluene in water.

  3. Dual-mode bioenabled nano-plasmonic sensors for biological and chemical detection

    Science.gov (United States)

    Kong, Xianming; Squire, Kenny; Xi, Yuting; LeDuff, Paul; Rorrer, Gregory L.; Wang, Alan X.

    2016-03-01

    Plasmonic biosensors have greatly overcome the limitations of conventional optical sensors in terms of sensitivity, tunability, photo-stability, and in vivo applicability. In this paper, we present plasmonic biosensors using bioenabled nanomaterials diatom biosilica, with active surface functionalities as affordable and eco-friendly integration platforms of Ag nanoparticles for label-free detection of biomolecules. Dual-mode plasmon sensing mechanisms, including surface-enhanced Raman scattering (SERS) and refractive-index (RI) sensing will be simultaneously implemented on the plasmonic-biosilica nanostructures to obtain quantitative biosensing with structural resolution of the biomolecules. We have achieved ultra-sensitive detection of Rhodamine 6G (R6G) at concentrations as low as 10-10 M. Furthermore, this substrate was used to detect TNT, illustrating the potential application as viable substrates for monitoring pollutant and toxics in environment.

  4. A facile synthesis of mesoporous Pdsbnd ZnO nanocomposites as efficient chemical sensor

    Science.gov (United States)

    Ismail, Adel A.; Harraz, Farid A.; Faisal, M.; El-Toni, Ahmed Mohamed; Al-Hajry, A.; Al-Assiri, M. S.

    2016-07-01

    Mesoporous ZnO was synthesized through the sol-gel method in the presence of triblock co-polymer Pluronic (F-127) template as the structure directing agent. Palladium nanoparticles were photochemically reduced and deposited onto mesoporous ZnO to obtain 1 wt.% Pd/ZnO nanocomposite. Structural and morphological analysis revealed high homogeneity and monodispersity of Pd nanoclusters with small particle sizes ∼ 2-5 nm onto mesoporous ZnO. The electrochemical detection of ethanol in aqueous solutions was conducted at the newly developed Pd/ZnO modified glassy carbon electrode (GCE) by the current-potential (IV) and cyclic voltammetry (CV) techniques and compared with bare GCE or pure ZnO. The presence of Pd dopant greatly enhances the sensitivity of ZnO, and the obtained mesoporous Pd/ZnO sensor has an excellent performance for precision detection of ethanol in aqueous solution with low concentration. The sensitivity was found to be 33.08 μAcm-2 mM-1 at lower concentration zone (0.05-0.8 mM) and 2.13 μAcm-2 mM-1 at higher concentration zone (0.8-12 mM), with a limit of detection (LOD) 19.2 μM. The kinetics study of ethanol oxidation revealed a characteristic feature for a mixed surface and diffusion-controlled process. These excellent sensing characteristics make the mesoporous Pd/ZnO nanocomposite a good candidate for the production of high-performance electrochemical sensors at low ethanol concentration in aqueous solution.

  5. Beyond potentiometry: robust electrochemical ion sensor concepts in view of remote chemical sensing.

    Science.gov (United States)

    Bakker, Eric; Bhakthavatsalam, Vishnupriya; Gemene, Kebede L

    2008-05-15

    For about 100 years, potentiometry with ion-selective electrodes has been one of the dominating electroanalytical techniques. While great advances in terms of selective chemistries and materials have been achieved in recent years, the basic manner in which ion-selective membranes are used has not fundamentally changed. The potential readings are directly co-dependent on the potential at the reference electrode, which requires maintenance and for which very few accepted alternatives have been proposed. Fouling or clogging of the exposed electrode surfaces will lead to changes in the observed potential. At the same time, the Nernst equation predicts quite small potential changes, on the order of millivolts for concentration changes on the order of a factor two, making frequent recalibration, accurate temperature control and electrode maintenance key requirements of routine analytical measurements. While the relatively advanced selective materials developed for ion-selective sensors would be highly attractive for low power remote sensing application, one should consider solutions beyond classical potentiometry to make this technology practically feasible. This paper evaluates some recent examples that may be attractive solutions to the stated problems that face potentiometric measurements. These include high-amplitude sensing approaches, with sensitivities that are an order of magnitude larger than predicted by the Nernst equation; backside calibration potentiometry, where knowledge of the magnitude of the potential is irrelevant and the system is evaluated from the backside of the membrane; controlled current coulometry with ion-selective membranes, an attractive technique for calibration-free reagent delivery without the need for standards or volumetry; localized electrochemical titrations at ion-selective membranes, making it possible to design sensors that directly monitor parameters such as total acidity for which volumetric techniques were traditionally used

  6. Physical and chemical stability of expired fixed dose combination artemether-lumefantrine in uncontrolled tropical conditions

    Directory of Open Access Journals (Sweden)

    Hess Kimberly

    2009-02-01

    Full Text Available Abstract Background New artemisinin combination therapies pose difficulties of implementation in developing and tropical settings because they have a short shelf-life (two years relative to the medicines they replace. This limits the reliability and cost of treatment, and the acceptability of this treatment to health care workers. A multi-pronged investigation was made into the chemical and physical stability of fixed dose combination artemether-lumefantrine (FDC-ALU stored under heterogeneous, uncontrolled African conditions, to probe if a shelf-life extension might be possible. Methods Seventy samples of expired FDC-ALU were collected from private pharmacies and malaria researchers in seven African countries. The samples were subjected to thin-layer chromatography (TLC, disintegration testing, and near infrared Raman spectrometry for ascertainment of active ingredients, tablet integrity, and chemical degradation of the tablet formulation including both active ingredients and excipients. Results Seventy samples of FDC-ALU were tested in July 2008, between one and 58 months post-expiry. 68 of 70 (97% samples passed TLC, disintegration and Raman spectrometry testing, including eight samples that were post-expiry by 20 months or longer. A weak linear association (R2 = 0.33 was observed between the age of samples and their state of degradation relative to brand-identical samples on Raman spectrometry. Sixty-eight samples were retested in February 2009 using Raman spectrometry, between eight and 65 months post-expiry. 66 of 68 (97% samples passed Raman spectrometry retesting. An unexpected observation about African drug logistics was made in three batches of FDC-ALU, which had been sold into the public sector at concessional pricing in accordance with a World Health Organization (WHO agreement, and which were illegally diverted to the private sector where they were sold for profit. Conclusion The data indicate that FDC-ALU is chemically and

  7. Concept Studies of Micro-Pump for Chemical Concentration in Handheld Micro Sensors

    Science.gov (United States)

    2007-11-02

    This report summarizes the preliminary results of a short-term innovative research project on the concept study of micro pumps for chemical...main objective of the work is to study the feasibility of certain micro pumping concepts and their potential integration with the sensing material and... micro pumps is demonstrated, although the quantitative assessment of the pumping system is still elusive, partly because of lack of specifications. The

  8. Combining machine learning, crowdsourcing and expert knowledge to detect chemical-induced diseases in text.

    Science.gov (United States)

    Bravo, Àlex; Li, Tong Shu; Su, Andrew I; Good, Benjamin M; Furlong, Laura I

    2016-01-01

    Drug toxicity is a major concern for both regulatory agencies and the pharmaceutical industry. In this context, text-mining methods for the identification of drug side effects from free text are key for the development of up-to-date knowledge sources on drug adverse reactions. We present a new system for identification of drug side effects from the literature that combines three approaches: machine learning, rule- and knowledge-based approaches. This system has been developed to address the Task 3.B of Biocreative V challenge (BC5) dealing with Chemical-induced Disease (CID) relations. The first two approaches focus on identifying relations at the sentence-level, while the knowledge-based approach is applied both at sentence and abstract levels. The machine learning method is based on the BeFree system using two corpora as training data: the annotated data provided by the CID task organizers and a new CID corpus developed by crowdsourcing. Different combinations of results from the three strategies were selected for each run of the challenge. In the final evaluation setting, the system achieved the highest Recall of the challenge (63%). By performing an error analysis, we identified the main causes of misclassifications and areas for improving of our system, and highlighted the need of consistent gold standard data sets for advancing the state of the art in text mining of drug side effects.Database URL: https://zenodo.org/record/29887?ln¼en#.VsL3yDLWR_V.

  9. Developmental effects of magnetic field (50 Hz) in combination with ionizing radiation and chemical teratogens.

    Science.gov (United States)

    Pafková, H; Jerábek, J; Tejnorová, I; Bednár, V

    1996-11-01

    The influence of a 50 Hz magnetic field (MF) on avian and mammalian embryogenesis, the MF level and vector, as well as the effect of exposure to MF (50 Hz, 10 mT) in combination with X-rays has been recently reported [2,3]. No significant alterations of chick or rat embryogenesis were found after repeated exposures to 50 Hz MF at 10 mT or 6 microT or with different vectors. However, X-ray chick embryotoxicity was significantly affected by repeated exposures of developing organisms to MF. A strong dependence of effect on the type of interaction was revealed. A decrease of X-ray induced teratogenicity was observed when MF preceded X-ray exposure (indirect interaction), while MF exposure applied immediately after X-ray radiation (direct interaction) non-significantly potentiated adverse developmental effects of ionizing radiation. This study deals with the effects of MF in combination with insulin or tetracycline. Exposure of chick embryos to MF influenced the sensitivity of embryonic morphogenetic systems to the subsequently administered chemical teratogens, insulin and/or tetracycline. A protective effect of MF was detected similarly as in the case of indirect interaction with ionizing radiation.

  10. On-line sensor monitoring for chemical contaminant attenuation during UV/H2O2 advanced oxidation process.

    Science.gov (United States)

    Yu, Hye-Weon; Anumol, Tarun; Park, Minkyu; Pepper, Ian; Scheideler, Jens; Snyder, Shane A

    2015-09-15

    A combination of surrogate parameters and indicator compounds were measured to predict the removal efficiency of trace organic compounds (TOrCs) using low pressure (LP)-UV/H2O2 advanced oxidation process (AOP), engaged with online sensor-based monitoring system. Thirty-nine TOrCs were evaluated in two distinct secondary wastewater effluents in terms of estimated photochemical reactivity, as a function of the rate constants of UV direct photolysis (kUV) and hydroxyl radical (OH) oxidation (kOH). The selected eighteen TOrCs were classified into three groups that served as indicator compounds: Group 1 for photo-susceptible TOrCs but with minor degradation by OH oxidation (diclofenac, fluoxetine, iohexol, iopamidol, iopromide, simazine and sulfamethoxazole); Group 2 for TOrCs susceptible to both direct photolysis and OH oxidation (benzotriazole, diphenhydramine, ibuprofen, naproxen and sucralose); and Group 3 for photo-resistant TOrCs showing dominant degradation by OH oxidation (atenolol, carbamazepine, DEET, gemfibrozil, primidone and trimethoprim). The results indicate that TOC (optical-based measurement), UVA254 or UVT254 (UV absorbance or transmittance at 254 nm), and total fluorescence can all be used as suitable on-line organic surrogate parameters to predict the attenuation of TOrCs. Furthermore, the automated real-time monitoring via on-line surrogate sensors and equipped with the developed degradation profiles between sensor response and a group of TOrCs removal can provide a diagnostic tool for process control during advanced treatment of reclaimed waters.

  11. Chemometric Classification of Herb – Orthosiphon stamineus According to Its Geographical Origin Using Virtual Chemical Sensor Based Upon Fast GC

    Directory of Open Access Journals (Sweden)

    Ezrinda Mohd Zaihidee

    2003-10-01

    Full Text Available An analytical method using Electronic Nose (E-nose instrument for analysis of volatile organic compound from Orthosiphon stamineus raw samples have been developed. This instrument is a new chemical sensor based on Fast Gas Chromatography and Surface Acoustics Wave (SAW detector. Chromatographic fingerprint obtained from the headspace analysis of O. stamineus samples were used as a guideline for optimum selection of an array of sensor. Qualitative analysis was carried out based on the responses of each sensor array in order to distinguish the geographical origin of the cultivated sample. The results of the analysis showed variances of volatile chemical compound of the samples even though it is from the same species. However, similarities of main components from all five samples were observed. Usage of pattern recognition chemometric approaches such as Principal Component Analysis (PCA, Linear Discriminant Analysis (LDA and Cluster Analysis (CA for processing instrumental data provided good classification of O. stamineus samples according to its geographical origin.

  12. Energy Efficiency of Ultra-Low-Power Bicycle Wireless Sensor Networks Based on a Combination of Power Reduction Techniques

    Directory of Open Access Journals (Sweden)

    Sadik Kamel Gharghan

    2016-01-01

    Full Text Available In most wireless sensor network (WSN applications, the sensor nodes (SNs are battery powered and the amount of energy consumed by the nodes in the network determines the network lifespan. For future Internet of Things (IoT applications, reducing energy consumption of SNs has become mandatory. In this paper, an ultra-low-power nRF24L01 wireless protocol is considered for a bicycle WSN. The power consumption of the mobile node on the cycle track was modified by combining adjustable data rate, sleep/wake, and transmission power control (TPC based on two algorithms. The first algorithm was a TPC-based distance estimation, which adopted a novel hybrid particle swarm optimization-artificial neural network (PSO-ANN using the received signal strength indicator (RSSI, while the second algorithm was a novel TPC-based accelerometer using inclination angle of the bicycle on the cycle track. Based on the second algorithm, the power consumption of the mobile and master nodes can be improved compared with the first algorithm and constant transmitted power level. In addition, an analytical model is derived to correlate the power consumption and data rate of the mobile node. The results indicate that the power savings based on the two algorithms outperformed the conventional operation (i.e., without power reduction algorithm by 78%.

  13. Structure Optimization of a Grain Impact Piezoelectric Sensor and Its Application for Monitoring Separation Losses on Tangential-Axial Combine Harvesters

    Directory of Open Access Journals (Sweden)

    Zhenwei Liang

    2015-01-01

    Full Text Available Grain separation losses is a key parameter to weigh the performance of combine harvesters, and also a dominant factor for automatically adjusting their major working parameters. The traditional separation losses monitoring method mainly rely on manual efforts, which require a high labor intensity. With recent advancements in sensor technology, electronics and computational processing power, this paper presents an indirect method for monitoring grain separation losses in tangential-axial combine harvesters in real-time. Firstly, we developed a mathematical monitoring model based on detailed comparative data analysis of different feeding quantities. Then, we developed a grain impact piezoelectric sensor utilizing a YT-5 piezoelectric ceramic as the sensing element, and a signal process circuit designed according to differences in voltage amplitude and rise time of collision signals. To improve the sensor performance, theoretical analysis was performed from a structural vibration point of view, and the optimal sensor structural has been selected. Grain collide experiments have shown that the sensor performance was greatly improved. Finally, we installed the sensor on a tangential-longitudinal axial combine harvester, and grain separation losses monitoring experiments were carried out in North China, which results have shown that the monitoring method was feasible, and the biggest measurement relative error was 4.63% when harvesting rice.

  14. Structure optimization of a grain impact piezoelectric sensor and its application for monitoring separation losses on tangential-axial combine harvesters.

    Science.gov (United States)

    Liang, Zhenwei; Li, Yaoming; Zhao, Zhan; Xu, Lizhang

    2015-01-14

    Grain separation losses is a key parameter to weigh the performance of combine harvesters, and also a dominant factor for automatically adjusting their major working parameters. The traditional separation losses monitoring method mainly rely on manual efforts, which require a high labor intensity. With recent advancements in sensor technology, electronics and computational processing power, this paper presents an indirect method for monitoring grain separation losses in tangential-axial combine harvesters in real-time. Firstly, we developed a mathematical monitoring model based on detailed comparative data analysis of different feeding quantities. Then, we developed a grain impact piezoelectric sensor utilizing a YT-5 piezoelectric ceramic as the sensing element, and a signal process circuit designed according to differences in voltage amplitude and rise time of collision signals. To improve the sensor performance, theoretical analysis was performed from a structural vibration point of view, and the optimal sensor structural has been selected. Grain collide experiments have shown that the sensor performance was greatly improved. Finally, we installed the sensor on a tangential-longitudinal axial combine harvester, and grain separation losses monitoring experiments were carried out in North China, which results have shown that the monitoring method was feasible, and the biggest measurement relative error was 4.63% when harvesting rice.

  15. Combined rigorous-generic direct orthorectification procedure for IRS-p6 sensors

    Science.gov (United States)

    Yousefzadeh, Meisam; Mojaradi, Barat

    2012-11-01

    The accessibility of global data, such as the digital elevation model (DEM), and the development of global visualisations allow promising new methods for minimising the distortion in the online generation of rough orthorectified products to be developed. Direct georeferencing (DG) has attracted a considerable amount of attention in the applications of pushbroom raw images in orthorectification or mono-plotting using ancillary satellite data. This study builds on recent DG studies to achieve an "orthoimage" from raw data and to determine potential mapping errors due to the DG procedure. Thus, this paper focuses on establishing a simple method for mitigating the misalignments of space-borne imageries to be used in direct orthorectification. Towards this goal, instead of image resectioning, affine transformation in different coordinate systems is employed in the orthorectification algorithm to compensate for the systematic DG errors. For a given point, the elevation corresponding to the obtained planimetric coordinate is extracted using available topographic maps and global DEMs, such as SRTM's and ASTER's DEMs. As a result, parameters no longer need to be updated, as in the conventional orthophoto generation methods. To evaluate the proposed procedures, experiments were conducted over three different IRS-p6 sensors in five datasets with different swath widths and tilt angles. The obtained results also demonstrate that the geographic coordinate system and a simple 2D affine transformation can efficiently correct misalignments.

  16. Experimental Study on Rebar Corrosion Using the Galvanic Sensor Combined with the Electronic Resistance Technique

    Science.gov (United States)

    Xu, Yunze; Li, Kaiqiang; Liu, Liang; Yang, Lujia; Wang, Xiaona; Huang, Yi

    2016-01-01

    In this paper, a new kind of carbon steel (CS) and stainless steel (SS) galvanic sensor system was developed for the study of rebar corrosion in different pore solution conditions. Through the special design of the CS and SS electronic coupons, the electronic resistance (ER) method and zero resistance ammeter (ZRA) technique were used simultaneously for the measurement of both the galvanic current and the corrosion depth. The corrosion processes in different solution conditions were also studied by linear polarization resistance (LPR) and the measurements of polarization curves. The test result shows that the galvanic current noise can provide detailed information of the corrosion processes. When localized corrosion occurs, the corrosion rate measured by the ER method is lower than the real corrosion rate. However, the value measured by the LPR method is higher than the real corrosion rate. The galvanic current and the corrosion current measured by the LPR method shows linear correlation in chloride-containing saturated Ca(OH)2 solution. The relationship between the corrosion current differences measured by the CS electronic coupons and the galvanic current between the CS and SS electronic coupons can also be used to evaluate the localized corrosion in reinforced concrete. PMID:27618054

  17. Use of MODIS Sensor Images Combined with Reanalysis Products to Retrieve Net Radiation in Amazonia.

    Science.gov (United States)

    de Oliveira, Gabriel; Brunsell, Nathaniel A; Moraes, Elisabete C; Bertani, Gabriel; Dos Santos, Thiago V; Shimabukuro, Yosio E; Aragão, Luiz E O C

    2016-06-24

    In the Amazon region, the estimation of radiation fluxes through remote sensing techniques is hindered by the lack of ground measurements required as input in the models, as well as the difficulty to obtain cloud-free images. Here, we assess an approach to estimate net radiation (Rn) and its components under all-sky conditions for the Amazon region through the Surface Energy Balance Algorithm for Land (SEBAL) model utilizing only remote sensing and reanalysis data. The study period comprised six years, between January 2001-December 2006, and images from MODIS sensor aboard the Terra satellite and GLDAS reanalysis products were utilized. The estimates were evaluated with flux tower measurements within the Large-Scale Biosphere-Atmosphere Experiment in Amazonia (LBA) project. Comparison between estimates obtained by the proposed method and observations from LBA towers showed errors between 12.5% and 16.4% and 11.3% and 15.9% for instantaneous and daily Rn, respectively. Our approach was adequate to minimize the problem related to strong cloudiness over the region and allowed to map consistently the spatial distribution of net radiation components in Amazonia. We conclude that the integration of reanalysis products and satellite data, eliminating the need for surface measurements as input model, was a useful proposition for the spatialization of the radiation fluxes in the Amazon region, which may serve as input information needed by algorithms that aim to determine evapotranspiration, the most important component of the Amazon hydrological balance.

  18. A colorimetric receptor combined with a microcantilever sensor for explosive vapor detection

    NARCIS (Netherlands)

    Zhu, W.; Park, J.S.; Sessler, J.L.; Gaitas, A.

    2011-01-01

    Substantial effort has been devoted to the synthesis of molecular receptors that can function as chemosensors for nitroaromatic explosives. In spite of several advantages, these receptors suffer from low sensitivity and difficulties translating the response into the gas phase. We have combined tetra

  19. Resolution Enhancement in Surface Plasmon Resonance Sensor Based on Waveguide Coupled Mode by Combining a Bimetallic Approach

    Directory of Open Access Journals (Sweden)

    Won Mok Kim

    2010-12-01

    Full Text Available In this study, we present and demonstrate a new route to a great enhancement in resolution of surface plasmon resonance sensors. Basically, our approach combines a waveguide coupled plasmonic mode and a kind of Au/Ag bimetallic enhancement concept. Theoretical modeling was carried out by solving Fresnel equations for the multilayer stack of prism/Ag inner-metal layer/dielectric waveguide/Au outer-metal layer. The inner Ag layer couples incident light to a guided wave and makes more fields effectively concentrated on the outer Au surface. A substantial enhancement in resolution was experimentally verified for the model stack using a ZnS-SiO2 waveguide layer.

  20. Selectivity of Chemoresistive Sensors Made of Chemically Functionalized Carbon Nanotube Random Networks for Volatile Organic Compounds (VOC

    Directory of Open Access Journals (Sweden)

    Jean-François Feller

    2014-01-01

    Full Text Available Different grades of chemically functionalized carbon nanotubes (CNT have been processed by spraying layer-by-layer (sLbL to obtain an array of chemoresistive transducers for volatile organic compound (VOC detection. The sLbL process led to random networks of CNT less conductive, but more sensitive to vapors than filtration under vacuum (bucky papers. Shorter CNT were also found to be more sensitive due to the less entangled and more easily disconnectable conducting networks they are making. Chemical functionalization of the CNT’ surface is changing their selectivity towards VOC, which makes it possible to easily discriminate methanol, chloroform and tetrahydrofuran (THF from toluene vapors after the assembly of CNT transducers into an array to make an e-nose. Interestingly, the amplitude of the CNT transducers’ responses can be enhanced by a factor of five (methanol to 100 (chloroform by dispersing them into a polymer matrix, such as poly(styrene (PS, poly(carbonate (PC or poly(methyl methacrylate (PMMA. COOH functionalization of CNT was found to penalize their dispersion in polymers and to decrease the sensors’ sensitivity. The resulting conductive polymer nanocomposites (CPCs not only allow for a more easy tuning of the sensors’ selectivity by changing the chemical nature of the matrix, but they also allow them to adjust their sensitivity by changing the average gap between CNT (acting on quantum tunneling in the CNT network. Quantum resistive sensors (QRSs appear promising for environmental monitoring and anticipated disease diagnostics that are both based on VOC analysis.