WorldWideScience

Sample records for chemical decontamination technical

  1. Chemical decontamination solutions: Effects on PWR equipment

    International Nuclear Information System (INIS)

    Pezze, C.M.; Colvin, E.R.; Aspden, R.G.

    1992-01-01

    A critical objective for the nuclear industry is the reduction of personnel exposure to radiation. Reductions have been achieved through industry's radiation management programs including training and radiation awareness concepts. Increased plant maintenance and higher radiation fields at many sites continue to raise concerns. To alleviate the radiation exposure problem, the sources of radiation which contribute to personnel exposure must be removed from the plant. A feasible was of significantly reducing these sources from a Pressurized Water Reactor (PWR) is to chemically decontaminate the entire reactor coolant system (RCS). A program was conducted to determine the technical acceptability of using certain dilute chemical solvent processes for full RCS chemical decontamination. The two processes evaluated were CAN-DEREM and LOMI. The purpose of the program was to define and complete a systematic evaluation of the major issues that need to be addressed for the successful decontamination of the entire RCS and affected portions of the auxiliary systems of a four-loop PWR system. A test program was designed to evaluate the corrosion effects of the two decontamination processes under expected plant conditions. Materials and sample configurations dictated by generic PWR components were evaluated. The testing also included many standard corrosion coupons. The test data were then used to assess the impact of chemical decontamination on the physical condition and operability of the components, equipment and mechanical systems that make up the RCS. An overview of the test program, sample configurations, data and engineering evaluations is presented. The data demonstrate that through detailed engineering evaluations of corrosion data and equipment function, the impact of full RCS chemical decontamination on plant equipment is established

  2. Chemical Gel for Surface Decontamination

    International Nuclear Information System (INIS)

    Jung, Chong Hun; Moon, J. K.; Won, H. J.; Lee, K. W.; Kim, C. K.

    2010-01-01

    Many chemical decontamination processes operate by immersing components in aggressive chemical solutions. In these applications chemical decontamination technique produce large amounts of radioactive liquid waste. Therefore it is necessary to develop processes using chemical gels instead of chemical solutions, to avoid the well-known disadvantages of chemical decontamination techniques while retaining their high efficiency. Chemical gels decontamination process consists of applying the gel by spraying it onto the surface of large area components (floors, walls, etc) to be decontaminated. The gel adheres to any vertical or complex surface due to their thixotropic properties and operates by dissolving the radioactive deposit, along with a thin layer of the gel support, so that the radioactivity trapped at the surface can be removed. Important aspects of the gels are that small quantities can be used and they show thixitropic properties : liquid during spraying, and solid when stationary, allowing for strong adherence to surfaces. This work investigates the decontamination behaviors of organic-based chemical gel for SS 304 metallic surfaces contaminated with radioactive materials

  3. Chemical decontamination method

    International Nuclear Information System (INIS)

    Nishiwaki, Hitoshi.

    1996-01-01

    Metal wastes contaminated by radioactive materials are contained in a rotational decontamination vessel, and the metal wastes are rotated therein while being in contact with a slight amount of a decontamination liquid comprising a mineral acid. As the mineral acid, a mixed acid of nitric acid, hydrochloric acid and fluoric acid is preferably used. Alternatively, chemical decontamination can also be conducted by charging an acid resistant stirring medium in the rotational decontamination vessel. The surface of the metal wastes is uniformly covered by the slight amount of decontamination liquid to dissolve the surface layer. In addition, heat of dissolution generated in this case is accumulated in the inside of the rotational decontamination vessel, the temperature is elevated with no particular heating, thereby enabling to obtain an excellent decontamination effect substantially at the same level as in the case of heating the liquid to 70degC in a conventional immersion decontamination method. Further, although contact areas between the metal wastes and the immersion vessel are difficult to be decontaminated in the immersion decontamination method, all of areas can be dissolved uniformly in the present invention. (T.M.)

  4. Chemical decontaminating method for stainless steel

    International Nuclear Information System (INIS)

    Onuma, Tsutomu; Akimoto, Hidetoshi.

    1990-01-01

    Radioactive metal wastes comprising passivated stainless steels are chemically decontaminated to such a radioactivity level as that of usual wastes. The present invention for chemically decontaminating stainless steels comprises a first step of immersing decontaminates into a sulfuric acid solution and a second step of immersing them into an aqueous solution prepared by adding oxidative metal salts to sulfuric acid, in which a portion of the surface of stainless steels as decontaminates are chemically ground to partially expose substrate materials and then the above-mentioned decontamination steps are applied. More than 90% of radioactive materials are removed in this method by the dissolution of the exposed substrate materials and peeling of cruds secured to the surface of the materials upon dissolution. This method is applicable to decontamination of articles having complicate shapes, can reduce the amount of secondary wastes after decontamination and also remarkably shorten the time required for decontamination. (T.M.)

  5. Testing and evaluation of eight decontamination chemicals

    International Nuclear Information System (INIS)

    Demmer, R.

    1994-09-01

    This report covers experimental work comparing eight different decontamination chemicals. Seven of these chemicals have some novelty, or are not currently in use at the ICPP. The eighth is a common ICPP decontamination reagent used as a baseline for effective comparison. Decontamination factors, waste generation values, and corrosion rates are tabulated for these chemicals. Recommendations are given for effective methods of non-sodium or low-sodium decontamination chemicals. The two most effective chemical for decontamination found in these test were a dilute hydrofluoric and nitric acid (HF/HNO 3 ) mixture and a fluoroboric acid solution. The fluoroboric acid solution (1 molar) was by far the most effective decontamination reagent, but suffered the problem of generating significant final calcine volume. The HF/HNO 3 solution performed a very good decontamination of the SIMCON coupons while generating only small amounts of calcine volume. Concentration variables were also tested, and optimized for these two solutions. Several oxidation/reduction decon chemical systems were also tested. These systems were similar to the TURCO 4502 and TURCO 4521 solutions used for general decontamination at the ICPP. A low sodium alternative, nitric acid/potassium permanganate, to the ''high sodium'' TURCO 4502 was tested extensively, optimized and recommended for general ICPP use. A reductive chemical solution, oxalic acid/nitric acid was also shown to have significant advantages

  6. Building surface decontamination for chemical counter-terrorism

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, S.; Thouin, G.; Kuang, W. [SAIC Canada, Ottawa, ON (Canada); Volchek, K.; Fingas, M.; Li, K. [Environment Canada, Ottawa, ON (Canada). Emergencies Science and Technology Division, Environmental Technology Centre, Science and Technology Branch

    2006-07-01

    A test method to compare and evaluate surface decontamination methods for buildings affected by chemical attacks was developed. Decontamination techniques generally depend on the nature and quantity of the weapon agent, the type of construction material and the location. Cleanup methods can be either physical, chemical or biological. This paper addressed chemical decontamination methods which use reactants to change the molecular structure of the contaminant. Peroxycarboxylic and peroxyacetic acids (PAA) are being used increasingly for both disinfection and environmental protection. In this study, 4 materials were chosen to represent common building materials. Samples were spiked with 10 mg of pesticides such as malathion and diazinon. Decontamination agents included the commercial decontamination agent CASCAD prepared in liquid form, a chemical preparation of PAA, and reagent grade peroxypropionic acid (PPA). The newly developed surface decontamination procedure can evaluate and compare the effectiveness of different chemical decontamination agents. The procedures were used on porous ceiling tile and carpet as well as on non-porous floor tile and painted steel surfaces. Rinse water was collected and analyzed in order to determine if decontamination was a result of chemical destruction or mechanical removal. The extraction efficiencies were found to be acceptable for all materials, with the exception of the highly porous ceiling tile. The extraction of diazinon from all surfaces was less efficient than the extraction of malathion. Results suggest that the performance of decontamination agents can be improved by repeated application of the decontamination agent, along with greater volumes and a combination of chemical and mechanical actions. It was also suggested that breakdown methods and wastewater treatment procedures should be developed because hazardous byproducts were detected in many samples. 18 refs., 1 tab., 17 figs.

  7. Full system chemical decontamination used in nuclear decommissioning

    International Nuclear Information System (INIS)

    Elder, George; Rottner, Bernard; Braehler, Georg

    2012-01-01

    The decommissioning of nuclear power stations at the end of the operational period of electricity generation offers technical challenges in the safe dismantling of the facility and the minimization of radioactive waste arising from the decommissioning activities. These challenges have been successfully overcome as demonstrated by decommissioning of the first generation of nuclear power plants. One of the techniques used in decommissioning is that of chemical decontamination which has a number of functions and advantages as given here: 1. Removal of contamination from metal surfaces in the reactors cooling systems. 2. Reduction of radioactive exposure to decommissioning workers 3. Minimization of metal waste by decontamination and recycling of metal components 4. Control of contamination when dismantling reactor and waste systems 5. Reduction in costs due to lower radiation fields, lower contamination levels and minimal metal waste volume for disposal. One such chemical decontamination technology was developed for the Electric Power Research Institute (EPRI) by Bradtec (Bradtec is an ONET Technologies subsidiary) and is known as the EPRI DFD system. This paper gives a description of the EPRI DFD system, and highlights the experience using the system. (orig.)

  8. Dilute chemical decontamination program review

    International Nuclear Information System (INIS)

    Anstine, L.D.; Blomgren, J.C.; Pettit, P.J.

    1980-01-01

    The objective of the Dilute Chemical Decontamination Program is to develop and evaluate a process which utilizes reagents in dilute concentrations for the decontamination of BWR primary systems and for the maintenance of dose rates on the out-of-core surfaces at acceptable levels. A discussion is presented of the process concept, solvent development, advantages and disadvantages of reagent systems, and VNC loop tests. Based on the work completed to date it is concluded that (1) rapid decontamination of BWRs using dilute reagents is feasible; (2) reasonable reagent conditions for rapid chemical decontamination are: 0.01M oxalic acid + 0.005M citric acid, pH3.0, 90/degree/C, 0.5 to 1.0 ppm dissolved oxygen; (3) control of dissolved oxygen concentration is important, since high levels suppress the rate of decontamination and low levels allow precipitation of ferrous oxalate. 4 refs

  9. Chemical decontamination method in nuclear facility system

    International Nuclear Information System (INIS)

    Takahashi, Ryota; Sakai, Hitoshi; Oka, Shigehiro.

    1996-01-01

    Pumps and valves in a closed recycling loop system incorporating materials to be chemically decontaminated are decomposed, a guide plate having the decomposed parts as an exit/inlet of a decontaminating liquid is formed, and a decontaminating liquid recycling loop comprising a recycling pump and a heater is connected to the guide plate. Decontaminating liquid from a decontaminating liquid storage tank is supplied to the decontaminating liquid recycling loop. With such constitutions, the decontaminating liquid is filled in the recycling closed loop system incorporating materials to be decontaminated, and the materials to be decontaminated are chemically decontaminated. The decontaminating liquid after the decontamination is discharged and flows, if necessary, in a recycling system channel for repeating supply and discharge. After the decontamination, the guide plate is removed and returned to the original recycling loop. When pipelines of a reactor recycling system are decontaminated, the amount of decontaminations can be decreased, and reforming construction for assembling the recycling loop again, which requires cutting for pipelines in the system is no more necessary. Accordingly, the amount of wastes can be decreased, and therefore, the decontamination operation is facilitated and radiation dose can be reduced. (T.M.)

  10. System for chemical decontamination of nuclear reactor primary systems

    International Nuclear Information System (INIS)

    Schlonski, J.S.; McGiure, M.F.; Corpora, G.J.

    1992-01-01

    This patent describes a method of chemically decontaminating a nuclear reactor primary system, having a residual heat removal system with one or more residual heat removal heat exchangers, each having an upstream and a downstream side, at or above ambient pressure. It comprises: injecting decontamination chemicals using an injection means; circulating the injected decontamination chemicals throughout the primary system; directing the circulated decontamination chemicals and process fluids to a means for removing suspended solids and dissolved materials after the circulated chemicals and process fluids have passed through the residual heat removal heat exchanger; decontaminating the process fluids; and feeding the decontaminated process fluids to the injection means. This patent also describes a chemical decontamination system for use at, or above, ambient pressure in a nuclear reactor primary system having a residual heat removal system. It comprises: means for injecting decontamination chemicals into the primary system; means for removing dissolved and suspended materials and decontamination chemicals from the primary system; one or more residual heat removal pumps; means located downstream of one of the residual heat removal heat exchangers; and a return line connecting the means

  11. Conversion of transuranic waste to low level waste by decontamination: a technical and economic evaluation

    International Nuclear Information System (INIS)

    Allen, R.P.; Hazelton, R.F.

    1984-12-01

    A study was conducted to evaluate the technical and economic feasibility of using in-situ decontamination techniques to convert glove boxes and other large TRU-contaminated components directly into LLW. The results of the technical evaluation indicate that in-situ decontamination of these types of components to non-TRU levels is technically feasible. Applicable decontamination techniques include electropolishing, hand scrubbing, chemical washes/sprays, strippable coatings and Freon spray-cleaning. The removal of contamination from crevices and other holdup areas remains a problem, but may be solved through further advances in decontamination technology. Also, the increase in the allowable maximum TRU level from 10 nCi/g to 100 nCi/g as defined in DOE Order 5820.2 reduces the removal requirement and facilitates measurement of the remaining quantities. The major emphasis of the study was on a cost/benefit evaluation that included a review and update of previous analyses and evaluations of TRU-waste volume reduction and conversion options. The results of the economic evaluation show, for the assumptions used, that there is a definite cost incentive to size reduce large components, and that decontamination of sectioned material has become cost competitive with the size reduction options. In-situ decontamination appears to be the lowest cost option when based on routine-type operations conducted by well-trained and properly equipped personnel. 16 references, 1 figure, 7 tables

  12. Chemically reducing decontamination method for radioactive metal

    International Nuclear Information System (INIS)

    Tanaka, Akio; Onuma, Tsutomu; Sato, Hitoshi.

    1994-01-01

    The present invention concerns a decontamination method of electrolytically reducing radioactive metal wastes, then chemically dissolving the surface thereof with a strong acid decontaminating solution. This method utilizes dissolving characteristics of stainless steels in the strong acid solution. That is, in the electrolytic reduction operation, a portion of the metal wastes is brought into contact with a strong acid decontaminating solution, and voltage and current are applied to the portion and keep it for a long period of time so as to make the potential of the immersed portion of the metal wastes to an active soluble region. Then, the electrolytic reduction operation is stopped, and the metal wastes are entirely immersed in the decontaminating solution to decontaminate by chemical dissolution. As the decontaminating solution, strong acid such as sulfuric acid, nitric acid is used. Since DC current power source capacity required for causing reaction in the active soluble region can be decreased, the decontamination facility can be minimized and simplified, and necessary electric power can be saved even upon decontamination of radioactive metal wastes made of stainless steels and having a great area. Further, chemical dissolution can be conducted without adding an expensive oxidizing agent. (N.H.)

  13. Reactive skin decontamination lotion (RSDL) for the decontamination of chemical warfare agent (CWA) dermal exposure.

    Science.gov (United States)

    Schwartz, M D; Hurst, C G; Kirk, M A; Reedy, S J D; Braue, E H

    2012-08-01

    Rapid decontamination of the skin is the single most important action to prevent dermal absorption of chemical contaminants in persons exposed to chemical warfare agents (CWA) and toxic industrial chemicals (TICs) as a result of accidental or intentional release. Chemicals on the skin may be removed by mechanical means through the use of dry sorbents or water. Recent interest in decontamination systems which both partition contaminants away from the skin and actively neutralize the chemical has led to the development of several reactive decontamination solutions. This article will review the recently FDA-approved Reactive Skin Decontamination Lotion (RSDL) and will summarize the toxicity and efficacy studies conducted to date. Evidence of RSDL's superior performance against vesicant and organophosphorus chemical warfare agents compared to water, bleach, and dry sorbents, suggests that RSDL may have a role in mass human exposure chemical decontamination in both the military and civilian arenas.

  14. Chemical decontamination of stainless steel

    International Nuclear Information System (INIS)

    Onuma, Tsutomu; Akimoto, Hidetoshi

    1991-01-01

    The present invention concerns a method for chemical decontamination of radioactive metal waste materials contaminated with radioactive materials on the surface, generated in radioactive materials-handling facilities. The invention is comprised of a method of chemical decontamination of stainless steel, characterized by comprising a first process of immersing a stainless steel-based metal waste material contaminated by radioactive materials on the surface in a sulfuric acid solution and second process of immersing in an aqueous solution of sulfuric acid and oxidizing metal salt, in which a portion of the surface of the stainless steel to be decontaminated is polished mechanically to expose a portion of the base material before the above first and second processes. 1 figs., 2 tabs

  15. Cost effectiveness of dilute chemical decontamination

    International Nuclear Information System (INIS)

    LeSurf, J.E.; Weyman, G.D.

    The basic principles of dilute chemical decontamination are described, as well as the method of application. Methods of computing savings in radiation dose and costs are presented, with results from actual experience and illustrative examples. It is concluded that dilute chemical decontamination is beneficial in many cases. It reduces radiation exposure of workers, saves money, and simplifies maintenance work

  16. Chemical decontamination: an overview

    International Nuclear Information System (INIS)

    Shaw, R.A.; Wood, C.J.

    1985-01-01

    The source of radioactive contamination in various types of power reactors is discussed. The methods of chemical decontamination vary with the manner in which the radioactive contaminants are deposited on the surface. Two types of dilute decontamination systems are available. One system uses organic acids and chelating agents, which are mildly reducing in nature. In this process, the oxide contaminants are removed by simple acidic dissolution and reductive dissolution. The second type of decontamination process is based on low oxidation state metal ions, which are more strongly reducing and do not require a corrosion inhibitor. All processes commercially available for decontamination of power reactors are not detailed here, but a few key issues to be considered in the selection of a process are highlighted. 2 figures, 2 tables

  17. Reactivity of Dual-Use Decontaminants with Chemical Warfare Agents

    Science.gov (United States)

    2016-07-01

    REACTIVITY OF DUAL-USE DECONTAMINANTS WITH CHEMICAL WARFARE AGENTS ECBC-TR-1384... Decontaminants with Chemical Warfare Agents 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Willis, Matthew P...extraction) of chemical warfare agents from materials. 15. SUBJECT TERMS GD HD Decontamination Hazard mitigation VX Chemical warfare agent Liquid-phase

  18. Two-step chemical decontamination technology

    International Nuclear Information System (INIS)

    Rankin, W.N.

    1992-01-01

    An improved two-step chemical decontamination technique was recently developed at INEL. This memorandum documents the addition of this technology to the SRTC arsenal of decontamination technology. A two-step process using NAOH, KMnO 4 followed by HNO 3 was used for cleaning doorstops (small casks) in the SRTC High Level Caves in 1967. Subsequently, more aggressive chemical techniques have been found to be much more effective for our applications. No further work on two-step technology is planned

  19. Mechanical and chemical decontamination of surfaces

    International Nuclear Information System (INIS)

    Kienhoefer, M.

    1982-01-01

    Decontamination does not mean more than a special technique of cleaning surfaces by methods well known in the industry. The main difference consists in the facts that more than just the visible dirt is to be removed and that radioactive contamination cannot be seen. Especially, intensive mechanical and chemical carry-off methods are applied to attack the surfaces. In order to minimize damages caused to the surfaces, the decontamination method is to adapt to the material and the required degree of decontamination. The various methods, their advantages and disadvantages are described, and the best known chemical solutions are shown. (orig./RW)

  20. Review of decontamination technologies for chemical counter-terrorism

    Energy Technology Data Exchange (ETDEWEB)

    Volchek, K.; Boudreau, L.; Hornof, M. [SAIC Canada, Ottawa, ON (Canada); Fingas, M.F.; Gamble, R.L. [Environment Canada, Ottawa, ON (Canada). Emergencies Science and Technology Div]|[Environment Canada, Ottawa, ON (Canada). River Road Environmental Technology Centre

    2004-07-01

    The two categories of chemical agents that could be used in acts of chemical terrorism are conventional chemical warfare agents and commercial toxic chemicals. Industrial chemicals are easier to access than warfare agents, and must therefore be considered when evaluating decontamination techniques. This study involved a search of public-domain documents to identify decontamination technologies including: physical/mechanical treatment or removal; chemical treatment; and, biological methods including natural degradation and attenuation. The technologies were analyzed with reference to their effectiveness for specific groups of chemical agents, state of development, availability and costs. Results indicate that there are many decontamination methods available, both developed and under development, that work effectively for most agents. The two most common decontamination methods are oxidation and alkali hydrolysis followed by dehalogenation. Technology limitations and gaps were also identified, suggesting a need for more research to further the development of promising processes. 31 refs., 2 tabs.

  1. A review of chemical decontamination systems for nuclear facilities

    International Nuclear Information System (INIS)

    Chen, L.; Chamberlain, D.B.; Conner, C.; Vandegrift, G.F.

    1996-01-01

    With the downsizing of the Department of Energy (DOE) complex, many of its buildings and facilities will be decommissioned and dismantled. As part of this decommissioning, some form of decontamination will be required. To develop an appropriate technology for in situ chemical decontamination of equipment interiors in the decommissioning of DOE nuclear facilities, knowledge of the existing chemical decontamination methods is needed. This paper attempts to give an up-to-date review of chemical decontamination methods. This survey revealed that aqueous systems are the most widely used for the decontamination and cleaning of metal surfaces. We have subdivided the aqueous systems by types of chemical solvent: acid, alkaline permanganate, highly oxidizing, peroxide, and proprietary. Two other systems, electropolishing and foams and gels, are also described in this paper

  2. [Decontamination of chemical and biological warfare agents].

    Science.gov (United States)

    Seto, Yasuo

    2009-01-01

    Chemical and biological warfare agents (CBWA's) are diverse in nature; volatile acute low-molecular-weight toxic compounds, chemical warfare agents (CWA's, gaseous choking and blood agents, volatile nerve gases and blister agents, nonvolatile vomit agents and lacrymators), biological toxins (nonvolatile low-molecular-weight toxins, proteinous toxins) and microbes (bacteria, viruses, rickettsiae). In the consequence management against chemical and biological terrorism, speedy decontamination of victims, facilities and equipment is required for the minimization of the damage. In the present situation, washing victims and contaminated materials with large volumes of water is the basic way, and additionally hypochlorite salt solution is used for decomposition of CWA's. However, it still remains unsolved how to dispose large volumes of waste water, and the decontamination reagents have serious limitation of high toxicity, despoiling nature against the environments, long finishing time and non-durability in effective decontamination. Namely, the existing decontamination system is not effective, nonspecifically affecting the surrounding non-target materials. Therefore, it is the urgent matter to build up the usable decontamination system surpassing the present technologies. The symposiast presents the on-going joint project of research and development of the novel decontamination system against CBWA's, in the purpose of realizing nontoxic, fast, specific, effective and economical terrorism on-site decontamination. The projects consists of (1) establishment of the decontamination evaluation methods and verification of the existing technologies and adaptation of bacterial organophosphorus hydrolase, (2) development of adsorptive elimination technologies using molecular recognition tools, and (4) development of deactivation technologies using photocatalysis.

  3. Aggressive chemical decontamination tests on small valves from the Garigliano BWR

    International Nuclear Information System (INIS)

    Bregani, F.

    1990-01-01

    In order to check the effectiveness of direct chemical decontamination on small and complex components, usually considered for storage without decontamination because of the small amount, some tests were performed on the DECO experimental loop. Four small stainless steel valves from the primary system of the Garigliano BWR were decontaminated using mainly aggressive chemicals such as HC1, HF, HNO 3 and their mixtures. On two valves, before the treatment with aggressive chemicals, a step with soft chemical (oxalic and citric acid mixture) was performed in order to see whether a softening action enhances the following aggressive decontamination. Moreover, in order to increase as much as possible the decontamination effectiveness, a decontamination process using ultrasounds jointly with aggressive chemicals was investigated. After an intensive laboratory testing programme, two smaller stainless steel valves from the primary system of the Garigliano BWR were decontaminated using ultrasounds in aggressive chemical solutions

  4. Effect of Organic Solvents in Preparation of Silica-Based Chemical Gel Decontaminates for Decontamination of Nuclear Facilities

    International Nuclear Information System (INIS)

    Yoon, Suk Bon; Jung, Chong Hun; Kim, Chang Ki; Choi, Byung Seon; Lee, Kune Woo; Moon, Jei Kwon

    2011-01-01

    Decontamination of nuclear facilities is necessary to reduce the radiation field during normal operations and decommissioning of complex equipment such as stainless steel components, other iron-based steel and alloys, metal surfaces, structural materials and so on. Chemical decontamination technology in particular is a highly effective method to remove the radioactive contamination through a chemical dissolution or a redox reaction. However, this method has the serious drawback due to the generation of large amounts of the radioactive liquid wastes. Recently, a few literatures have been reported for the preparation of the chemical gel decontaminants to reduce the amount of the radioactive liquid wastes and to enhance the decontamination efficiency through increasing the contact time between the gels and the radioactive contaminants. In the preparation of the chemical gels, the control of the viscosity highly depends on the amount of a coviscosifier used among the components of the chemical gels consisted of a viscosifier, a coviscosifier, and a chemical decontaminant. In this works, a new effective method for the preparation of the chemical gel was investigated by introducing the organic solvents. The mixture solution of the coviscosifier and organic solvent was more effective in the control of the viscosity compared with that of the coviscosifier only in gels. Furthermore, the decontamination efficiency of the chemical gels measured by using the multi-channel analyzer (MCA) showed the high decontamination factor for Co-60 and Cs-137 contaminated on the surface of the stainless steel 304

  5. Recent developments in chemical decontamination technology

    Energy Technology Data Exchange (ETDEWEB)

    Wood, C.J. [Electric Power Research Institute, Palo Alto, CA (United States)

    1995-03-01

    Chemical decontamination of parts of reactor coolant systems is a mature technology, used routinely in many BWR plants, but less frequently in PWRs. This paper reviews recent developments in the technology - corrosion minimization, waste processing and full system decontamination, including the fuel. Earlier work was described in an extensive review published in 1990.

  6. Assessment of chemical processes for the post-accident decontamination of reactor-coolant systems. Final report

    International Nuclear Information System (INIS)

    Munson, L.F.; Card, C.J.; Divine, J.R.

    1983-02-01

    Previously used chemical decontamination processes and potentially useful new decontamination processes were examined for the usefulness following a reactor accident. Both generic fuel damage accidents and the accident at TMI-2 were considered. A total of fourteen processes were evaluated. Process evaluation included data in the following categories: technical description of the process, recorded past usage, effectiveness, process limitation, safety consideration, and waste management. These data were evaluated, and cost considerations were presented along with a description of the applicability of the process to TMI-2 and development and demonstration needs. Specific recommendations regarding a primary-system decontamination development program to support TMI-2 recovery were also presented

  7. A survey of decontamination processes applicable to DOE nuclear facilities

    International Nuclear Information System (INIS)

    Chen, L.; Chamberlain, D.B.; Conner, C.; Vandegrift, G.F.

    1997-05-01

    The objective of this survey was to select an appropriate technology for in situ decontamination of equipment interiors as part of the decommissioning of U.S. Department of Energy nuclear facilities. This selection depends on knowledge of existing chemical decontamination methods. This report provides an up-to-date review of chemical decontamination methods. According to available information, aqueous systems are probably the most universally used method for decontaminating and cleaning metal surfaces. We have subdivided the technologies, on the basis of the types of chemical solvents, into acid, alkaline permanganate, highly oxidizing, peroxide, and miscellaneous systems. Two miscellaneous chemical decontamination methods (electrochemical processes and foam and gel systems) are also described. A concise technical description of various processes is given, and the report also outlines technical considerations in the choice of technologies, including decontamination effectiveness, waste handing, fields of application, and the advantages and limitations in application. On the basis of this survey, six processes were identified for further evaluation. 144 refs., 2 tabs

  8. A survey of decontamination processes applicable to DOE nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Chen, L.; Chamberlain, D.B.; Conner, C.; Vandegrift, G.F.

    1997-05-01

    The objective of this survey was to select an appropriate technology for in situ decontamination of equipment interiors as part of the decommissioning of U.S. Department of Energy nuclear facilities. This selection depends on knowledge of existing chemical decontamination methods. This report provides an up-to-date review of chemical decontamination methods. According to available information, aqueous systems are probably the most universally used method for decontaminating and cleaning metal surfaces. We have subdivided the technologies, on the basis of the types of chemical solvents, into acid, alkaline permanganate, highly oxidizing, peroxide, and miscellaneous systems. Two miscellaneous chemical decontamination methods (electrochemical processes and foam and gel systems) are also described. A concise technical description of various processes is given, and the report also outlines technical considerations in the choice of technologies, including decontamination effectiveness, waste handing, fields of application, and the advantages and limitations in application. On the basis of this survey, six processes were identified for further evaluation. 144 refs., 2 tabs.

  9. Chemical decontamination process and device therefor

    International Nuclear Information System (INIS)

    Takahashi, Ryota; Sakai, Hitoshi

    1998-01-01

    The present invention provides a process and a device for chemical decontamination, which can suppress corrosion of low corrosion resistant materials, keep decontamination properties substantially as same as before and further, reduce the volume of secondary wastes. In a step of reductively melting oxide membranes on an objective material to be decontaminated, a mixture of oxalic acid and a salt thereof is used as a reducing agent, and the reductive melting is conducted while suppressing hydrogen ion concentration of an aqueous liquid system. In order to enhance the reducibility of the oxalic acid ions, it is desirable to add a cyclic hetero compound thereto. The device of the present invention comprises, a decontamination loop including a member to be decontaminated, a heater and a pH meter, a medical injection pump for injecting a reducing agent to the decontamination loop, a metal ion recovering loop including an ion exchange resin tower, a reducing agent decomposing loop including an electrolytic vessel and/or a UV ray irradiation cell, a circulation pump for circulating the decontamination liquid to each of the loops and a plurality of opening/closing valves for switching the loop in which the decontamination liquid is circulated. (T.M.)

  10. Decontamination of the chemical crane room and decontamination and decommissioning of the extraction chemical room at the West Valley Demonstration Project

    International Nuclear Information System (INIS)

    Phillips, E.C.; Golden, M.P.

    1986-01-01

    This paper describes the decontamination of the Chemical Crane Room (CCR) of the West Valley Plant and the Extraction Chemical Room (XCR) from radioactively contaminated conditions to essentially shirt sleeve environments. In both cases, subsequent use re-contaminated the rooms. Prior to decontamination, general exposure rates in the CCR were 50 to 100 mR/hr with hot spots as high as 2000 mR/hr. Smearable levels on the floor were in the range of 10 5 to 10 6 dpm per 100/cm 2 . Respiratory protection was mandatory for entry. In the Extraction Chemical Room (XCR) prior to decontamination and decommissioning (D/D), radiological surveys indicated a maximum radiation field of 5 mR/hr, due to sources internal to the room, and 20,000 dpm beta/100 cm 2 surface contamination. A radiation source external to the XCR caused a hot spot with a 9 mR/hr exposure rate inside the XCR. The CCR, located at the north end of the Chemical Process Cell (CPC) is for the storage and servicing of two bridge cranes used in the CPC. Decontamination and exposure reduction in the CCR has been completed using vacuum cleaning, damp wipe down, and surface grinding followed by shielding and painting. The decontamination and decommissioning of the Extraction Chemical Room (XCR), located on the fifth floor elevation (160') of the reprocessing plant at the WVDP, has been completed. D/D operations included removal of piping, tanks, supports, and equipment to provide a clean work area of about 3000 square feet and 17 feet high

  11. Chemical and mechanical decontamination processes to minimize secondary waste decommissioning

    International Nuclear Information System (INIS)

    Enda, M.; Ichikawa, N.; Yaita, Y.; Kanasaki, T.; Sakai, H.

    2008-01-01

    In the decommissioning of commercial nuclear reactors in Japan, prior to the dismantling of the nuclear power plants, there are plans to use chemical techniques to decontaminate reactor pressure vessels (RPVs), internal parts, primary loop recirculation systems (PLRs), reactor water clean up systems (RWCUs), etc., so as to minimize radiation sources in the materials to be disposed of. After dismantling the nuclear power plants, chemical and mechanical decontamination techniques will then be used to reduce the amounts of radioactive metallic waste. Toshiba Corporation has developed pre-dismantling and post-dismantling decontamination systems. In order to minimize the amounts of secondary waste, the T-OZON process was chosen for decontamination prior to the dismantling of nuclear power plants. Dismantling a nuclear power plant results in large amounts of metallic waste requiring decontamination; for example, about 20,000 tons of such waste is expected to result from the dismantling of a 110 MWe Boiling Water Reactor (BWR). Various decontamination methods have been used on metallic wastes in preparation for disposal in consideration of the complexity of the shapes of the parts and the type of material. The materials in such nuclear power plants are primarily stainless steel and carbon steel. For stainless steel parts having simple shapes, such as plates and pipes, major sources of radioactivity can be removed from the surface of the parts by bipolar electrolysis (electrolyte: H 2 SO 4 ). For stainless steel parts having complicated shapes, such as valves and pumps, major sources of radioactivity can be removed from the surfaces by redox chemical decontamination treatments (chemical agent: Ce(IV)). For carbon steel parts having simple shapes, decontamination by blasting with zirconia grit is effective in removing major sources of radioactivity at the surface, whereas for carbon steel parts having complicated shapes, major sources of radioactivity can be removed from

  12. Chemical hazards from decontamination solutions in low level waste

    International Nuclear Information System (INIS)

    Leventhal, L.; Miller, A.; Turney, J.; Naughton, M.; IMPELL Corp., Walnut Creek, CA; Electric Power Research Inst., Palo Alto, CA)

    1985-01-01

    Recent regulations are focussing more attention on the non-radioactive matrix materials associated with radioactive wastes. Decontamination of operating facilities is becoming a more significant source of low-level waste. This study reviewed the chemical and biological hazards of over 50 decontamination processes. Seventeen of the most prominent hard and soft decontamination processes were examined in detail. The chemical and biological hazards of these seventeen are presented in this paper. These hazards influence the choice of radwaste processing and packaging operations and methods. Federal, state and local regulations further impact on operations and waste disposal. Hazards to personnel, in plant and off-site, resulting from the decontamination cycle are evaluated. 1 fig., 5 tabs

  13. Chemical decontamination of non-dismounted equipment of nuclear power stations

    International Nuclear Information System (INIS)

    Oertel, K.; Dietrich, P.; Hildebrandt, N.

    1979-01-01

    Reasons for performing system chemical decontaminations are considered, some cases of practical application to water cooled power reactors are discussed, radical and soft decontamination techniques are compared with each other, and evaluation criteria for decontaminations are studied. (author)

  14. Decontamination and management of human remains following incidents of hazardous chemical release.

    Science.gov (United States)

    Hauschild, Veronique D; Watson, Annetta; Bock, Robert

    2012-01-01

    To provide specific guidance and resources for systematic and orderly decontamination of human remains resulting from a chemical terrorist attack or accidental chemical release. A detailed review and health-based decision criteria protocol is summarized. Protocol basis and logic are derived from analyses of compound-specific toxicological data and chemical/physical characteristics. Guidance is suitable for civilian or military settings where human remains potentially contaminated with hazardous chemicals may be present, such as sites of transportation accidents, terrorist operations, or medical examiner processing points. Guidance is developed from data-characterizing controlled experiments with laboratory animals, fabrics, and materiel. Logic and specific procedures for decontamination and management of remains, protection of mortuary affairs personnel, and decision criteria to determine when remains are sufficiently decontaminated are presented. Established procedures as well as existing materiel and available equipment for decontamination and verification provide reasonable means to mitigate chemical hazards from chemically exposed remains. Unique scenarios such as those involving supralethal concentrations of certain liquid chemical warfare agents may prove difficult to decontaminate but can be resolved in a timely manner by application of the characterized systematic approaches. Decision criteria and protocols to "clear" decontaminated remains for transport and processing are also provided. Once appropriate decontamination and verification have been accomplished, normal procedures for management of remains and release can be followed.

  15. NRC regulations and positions concerning decontamination

    International Nuclear Information System (INIS)

    McCracken, C.

    1982-09-01

    The U.S. Nuclear Regulatory Commission encourages the use of decontamination to reduce man-rem exposure. The Commission feels that there are several processes developed to the point where soft decontamination can be applied to an entire plant in the near future. A utility can do a decontamination under its own licence without coming in for regulatory review if the process does not involve a change in technical specifications for the plant or does not involve unreviewed safety questions. Prior verbal notification is required for some steam generator secondary side cleaning or for decontamination of individual components that have not been removed from the reactor using chemicals not normally added to the reactor coolant. Prior written notification is required for steam generator secondary side crevice cleaning or sludge removal at a dented unit, or for chemical decontamination of reactor coolant systems or safety-related systems using chemicals not normally added to the coolant

  16. New decontamination techniques: chemical gels, electropolishing and abrasives

    International Nuclear Information System (INIS)

    Brunel, G.; Gauchon, J.P.; Kervegant, Y.; Josso, F.

    1991-01-01

    The decommissioning of nuclear installations requires decontamination techniques that are efficient, simple to apply and producing a small amount of wastes, which are easy to process. With a view to this, three decontamination methods, which appear to be particularly suited to decommissioning, have been studied. These three methods are: - spraying of gels carrying chemical decontaminating agents, - electropolishing with a swab device, - abrasives blasting. After parametric tests on non-radioactive and active samples, the industrial application of these methods in the dismantling of installations was studied. These industrial applications concern: - decontamination of pieces coming from the German BWR ISAR by immersion and gel spraying, - decontamination, mainly by gel spraying, and dismantling of the BRENNILIS bituminisation plant, - decontamination of part of the cooling circuit of the graphite gas reactor G2 by gel spraying, - decontamination of a component of the FBR SuperPhenix, using dry abrasives blasting. During the first three applications, generated secondary wastes volume and form were determined. 33 tabs., 16 figs., 12 refs

  17. Enzymatic Decontamination of Chemical Warfare Agents

    National Research Council Canada - National Science Library

    Raushel, Frank

    2000-01-01

    The primary objective of this research program is the development of a versatile enzyme-based system that is fully optimized for the decontamination, destruction, and detection of know chemical warfare agents...

  18. Chemical, biological, radiological, and nuclear decontamination: Recent trends and future perspective

    Directory of Open Access Journals (Sweden)

    Vinod Kumar

    2010-01-01

    Full Text Available Chemical, biological, radiological, and nuclear (CBRN decontamination is the removal of CBRN material from equipment or humans. The objective of the decontamination is to reduce radiation burden, salvage equipment, and materials, remove loose CBRN contaminants, and fix the remaining in place in preparation for protective storage or permanent disposal work activities. Decontamination may be carried out using chemical, electrochemical, and mechanical means. Like materials, humans may also be contaminated with CBRN contamination. Changes in cellular function can occur at lower radiation doses and exposure to chemicals. At high dose, cell death may take place. Therefore, decontamination of humans at the time of emergency while generating bare minimum waste is an enormous task requiring dedication of large number of personnel and large amount of time. General principles of CBRN decontamination are discussed in this review with emphasis on radiodecontamination.

  19. Decontamination Systems Information and Research Program. Quarterly technical progress report, January 1--March 31, 1994

    Energy Technology Data Exchange (ETDEWEB)

    1994-05-01

    West Virginia University (WVU) and the US DOE Morgantown Energy Technology Center (METC) entered into a Cooperative Agreement on August 29, 1992 entitled ``Decontamination Systems Information and Research Programs.`` Stipulated within the Agreement is the requirement that WVU submit to METC a series of Technical Progress Reports on a quarterly basis. This report comprises the first Quarterly Technical Progress Report for Year 2 of the Agreement. This report reflects the progress and/or efforts performed on the sixteen (16) technical projects encompassed by the Year 2 Agreement for the period of January 1 through March 31, 1994. In situ bioremediation of chlorinated organic solvents; Microbial enrichment for enhancing in-situ biodegradation of hazardous organic wastes; Treatment of volatile organic compounds (VOCs) using biofilters; Drain-enhanced soil flushing (DESF) for organic contaminants removal; Chemical destruction of chlorinated organic compounds; Remediation of hazardous sites with steam reforming; Soil decontamination with a packed flotation column; Use of granular activated carbon columns for the simultaneous removal of organics, heavy metals, and radionuclides; Monolayer and multilayer self-assembled polyion films for gas-phase chemical sensors; Compact mercuric iodide detector technology development; Evaluation of IR and mass spectrometric techniques for on-site monitoring of volatile organic compounds; A systematic database of the state of hazardous waste clean-up technologies; Dust control methods for insitu nuclear and hazardous waste handling; Winfield Lock and Dam remediation; and Socio-economic assessment of alternative environmental restoration technologies.

  20. Chemical Decontamination at Browns Ferry Unit 1

    International Nuclear Information System (INIS)

    Hartwig, Ed; Reid, Richard

    2003-01-01

    In May, 2002, the Tennessee Valley Authority's (TVA) Board of Directors approved the recovery and restart of Unit 1 at Browns Ferry Nuclear Station. As an initial step in the site characterization and restart feasibility review, a majority of the primary reactor circuit was chemically decontaminated. Close cooperation between TVA and vendor personnel resulted in project completion ahead of schedule with outstanding results. The final average decontamination factors were excellent, and the final dose rates were very low, with contact readings on most points between one and three mRem/hr. In addition to allowing TVA to do a complete and thorough job of determining the feasibility of the Unit 1 restart, the decontamination effort will greatly reduce personnel exposure during plant recovery, both whole body exposure to gamma radiation and airborne exposure during pipe replacement efforts. The implementation of lessons learned from previous decontamination work performed at Browns Ferry, as well as decontamination efforts at other plants aided greatly in the success. Specific items of note are: (1) The initial leak check of the temporary decontamination system should include ancillary systems such as the spent resin system, as well as the main circulation loop. This could save time and dose exposure if leaks are discovered before the use of such systems is required. (2) Due to the quick turnaround time from the award of contract, a vendor representative was onsite early in the project to help with engineering efforts and procedures. This aided greatly in completing preparations for the decontamination. (3) The work was performed under a single maintenance activity. This resulted in great craft and plant support. (4) The constant coverage by the site's decontamination flush directors provided timely plant support and interface. (5) The FPC system isolation and back flushing to prevent residual chemicals from being left in the FPC system should have been addressed in more

  1. Chemical decontamination and melt densification

    International Nuclear Information System (INIS)

    Dillon, R.L.; Griggs, B.; Kemper, R.S.; Nelson, R.G.

    1976-01-01

    Preliminary studies on the chemical decontamination and densification of Zircaloy, stainless steel, and Inconel undissolved residues remaining after dissolution of the UO 2 --PuO 2 spent fuel material from sheared fuel bundles are reported. The studies were made on cold or very small samples to demonstrate the feasibility of the processes developed before proceeding to hot cell demonstrations with kg level of the sources. A promising aqueous decontamination method for Zr alloy cladding was developed in which oxidized surfaces are conditioned with HF prior to leaching with ammonium oxalate, ammonium citrate, ammonium fluoride, and hydrogen peroxide. Feasibility of molten salt decontamination of oxidized Zircaloy was demonstrated. A low melting alloy of Zircaloy, stainless steel, and Inconel was obtained in induction heated graphite crucibles. Segregated Zircaloy cladding sections were directly melted by the inductoslag process to yield a metal ingot suitable for storage. Both Zircaloy and Zircaloy--stainless steel--Inconel alloys proved to be highly satisfactory getters and sinks for recovered tritium

  2. Reactor component chemical decontamination-developments in waste handling and disposal

    International Nuclear Information System (INIS)

    Papesch, R.; Atwood, K.L.

    1989-01-01

    Because of restrictive limits on man-rem exposure in European nuclear plants, a company has developed and applied a number of chemical decontamination techniques for components that must be periodically maintained. These techniques are particularly effective for components that can be placed in a decontamination bath for dose reduction prior to performing maintenance. The cleaning technique has the ability to achieve decontamination factors of at least 20 and in some cases much greater. For components with before cleaning dose rates of between 1 to as high as 80 R/hr, significant man-rem reductions are achieved when hundreds of manhours may be required to complete required component maintenance. Transferring this solvent technology to the U.S. required a program to develop solidification formulas to allow the solvent wastes to be disposed of in accordance with regulations and in a cost effective manner. This paper demonstrates in chemical decontaminations with small liquid volume systems that concentrated decontamination solvents can be employed to achieve high decontamination factors

  3. Transport and Reactivity of Decontaminants to Provide Hazard Mitigation of Chemical Warfare Agents from Materials

    Science.gov (United States)

    2016-06-01

    2013 4. TITLE AND SUBTITLE Transport and Reactivity of Decontaminants to Provide Hazard Mitigation of Chemical Warfare Agents from Materials 5a...directions for future decontamination formulation approaches. 15. SUBJECT TERMS GD HD Decontamination Hazard mitigation VX Chemical warfare agent... DECONTAMINANTS TO PROVIDE HAZARD MITIGATION OF CHEMICAL WARFARE AGENTS FROM MATERIALS 1. INTRODUCTION Decontamination of materials is the

  4. Technical soaps - a possibility of decontaminating thorium-contaminated waste waters

    International Nuclear Information System (INIS)

    Drathen, H.; Erichsen, L. v.

    1977-01-01

    Thorium-contaminated waste waters showing a concentration of thorium higher than 10sup(-5) mol/l can be quantitatively decontaminated by adding soaps. Concentrations of impurity ions of both tap and sea waters have been taken into consideration. As there is no difference between soaps and soap mixtures concerning the quantity of precipitation rates, technical soaps are from the economic point of view best suited for decontaminating thorium-contaminated waste waters. Having a soap concentration of 200% of the stoichiometric amount of thorium and a concentration of impurity ions of 10sup(-2) mol/l, it is assumed that decontamination factors of more than 20 can be reached in one step. (orig.) [de

  5. Development of waste minimization and decontamination technologies at the Idaho Chemical Processing Plant

    International Nuclear Information System (INIS)

    Ferguson, R.L.; Archibald, K.E.; Demmer, R.L.

    1995-01-01

    Emphasis on the minimization of decontamination secondary waste has increased because of restrictions on the use of hazardous chemicals and Idaho Chemical Processing Plant (ICPP) waste handling issues. The Lockheed Idaho Technologies Co. (LITCO) Decontamination Development Subunit has worked to evaluate and introduce new performed testing, evaluations, development and on-site demonstrations for a number of novel decontamination techniques that have not yet previously been used at the ICPP. This report will include information on decontamination techniques that have recently been evaluated by the Decontamination Development Subunit

  6. Studies on residue-free decontaminants for chemical warfare agents.

    Science.gov (United States)

    Wagner, George W

    2015-03-17

    Residue-free decontaminants based on hydrogen peroxide, which decomposes to water and oxygen in the environment, are examined as decontaminants for chemical warfare agents (CWA). For the apparent special case of CWA on concrete, H2O2 alone, without any additives, effectively decontaminates S-2-(diisopropylamino)ethyl O-ethyl methylphosphonothioate (VX), pinacolyl methylphosphorofluoridate (GD), and bis(2-choroethyl) sulfide (HD) in a process thought to involve H2O2 activation by surface-bound carbonates/bicarbonates (known H2O2 activators for CWA decontamination). A plethora of products are formed during the H2O2 decontamination of HD on concrete, and these are characterized by comparison to synthesized authentic compounds. As a potential residue-free decontaminant for surfaces other than concrete (or those lacking adsorbed carbonate/bicarbonate) H2O2 activation for CWA decontamination is feasible using residue-free NH3 and CO2 as demonstrated by reaction studies for VX, GD, and HD in homogeneous solution. Although H2O2/NH3/CO2 ("HPAC") decontaminants are active for CWA decontamination in solution, they require testing on actual surfaces of interest to assess their true efficacy for surface decontamination.

  7. Comprehensive investigation of the corrosion and surface chemical effects of the decontamination technologies

    International Nuclear Information System (INIS)

    Szabo-Nagy, Andrea; Varga, Kalman; Deak-Horvath, Emese; Nemeth, Zoltan; Horvath, David; Schunk, Janos; Patek, Gabor

    2012-09-01

    Decontamination technologies are mainly developed to reduce the collective dose of the maintenance personnel at NPPs. The highest efficiency (i.e., the highest DF values) available without detrimental modification of the treated surface of structural material is the most important goal in the course of the application of a decontamination technology. A so-called 'soft' chemical decontamination technology has been developed - supported by the Paks Nuclear Power Plant - at the Institute of Radiochemistry and Radioecology of the University of Pannonia. The novel base technology can be effectively applied for the decontamination of the heat exchanger tubes of steam generators. In addition, by optimizing the main technological parameters (temperature, concentration of the liquid chemicals, flow rates, contact time, etc.) it can be utilized for specific applications such as decontamination of some dismountable devices and separable equipment or the total decontamination prior to plant dismantling (decommissioning) in the future. The aim of this work is to compare the efficiency, corrosion and surface chemical effects of some improved versions of the novel base-technology elaborated for decontamination of austenitic stainless steel surfaces. The experiments have been performed at laboratory conditions in decontamination model systems. The applied methods: γ-spectrometry, ICP-OES, voltammetry and SEM-EDX. The experimental results revealed that the efficiency of the base-technology mainly depends on the surface features of the stainless steel samples such as the chemical composition and thickness of the oxide layer, the nature (quantity, morphology and chemical composition) of the crystalline deposits. It has been documented that the improved version of the base-technology are suitable for the decontamination of both steel surfaces covered by chemically resistant large Cr-content crystals and that having compact oxide-layers (up to a thickness of 10

  8. Chemical analysis of bleach and hydroxide-based solutions after decontamination of the chemical warfare agent O-ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX).

    Science.gov (United States)

    Hopkins, F B; Gravett, M R; Self, A J; Wang, M; Chua, Hoe-Chee; Hoe-Chee, C; Lee, H S Nancy; Sim, N Lee Hoi; Jones, J T A; Timperley, C M; Riches, J R

    2014-08-01

    Detailed chemical analysis of solutions used to decontaminate chemical warfare agents can be used to support verification and forensic attribution. Decontamination solutions are amongst the most difficult matrices for chemical analysis because of their corrosive and potentially emulsion-based nature. Consequently, there are relatively few publications that report their detailed chemical analysis. This paper describes the application of modern analytical techniques to the analysis of decontamination solutions following decontamination of the chemical warfare agent O-ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX). We confirm the formation of N,N-diisopropylformamide and N,N-diisopropylamine following decontamination of VX with hypochlorite-based solution, whereas they were not detected in extracts of hydroxide-based decontamination solutions by nuclear magnetic resonance (NMR) spectroscopy or gas chromatography-mass spectrometry. We report the electron ionisation and chemical ionisation mass spectroscopic details, retention indices, and NMR spectra of N,N-diisopropylformamide and N,N-diisopropylamine, as well as analytical methods suitable for their analysis and identification in solvent extracts and decontamination residues.

  9. Binding affinity and decontamination of dermal decontamination gel to model chemical warfare agent simulants.

    Science.gov (United States)

    Cao, Yachao; Elmahdy, Akram; Zhu, Hanjiang; Hui, Xiaoying; Maibach, Howard

    2018-05-01

    Six chemical warfare agent simulants (trimethyl phosphate, dimethyl adipate, 2-chloroethyl methyl sulfide, diethyl adipate, chloroethyl phenyl sulfide and diethyl sebacate) were studied in in vitro human skin to explore relationship between dermal penetration/absorption and the mechanisms of simulant partitioning between stratum corneum (SC) and water as well as between dermal decontamination gel (DDGel) and water. Both binding affinity to and decontamination of simulants using DDGel were studied. Partition coefficients of six simulants between SC and water (Log P SC/w ) and between DDGel and water (Log P DDGel/w ) were determined. Results showed that DDGel has a similar or higher binding affinity to each simulant compared to SC. The relationship between Log P octanol/water and Log P SC/w as well as between Log P octanol/water and Log P DDGel/w demonstrated that partition coefficient of simulants correlated to their lipophilicity or hydrophilicity. Decontamination efficiency results with DDGel for these simulants were consistent with binding affinity results. Amounts of percentage dose of chemicals in DDGel of trimethyl phosphate, dimethyl adipate, 2-chloroethyl methyl sulfide, diethyl adipate, chloroethyl phenyl sulfide and diethyl sebacate were determined to be 61.15, 85.67, 75.91, 53.53, 89.89 and 76.58, with corresponding amounts absorbed in skin of 0.96, 0.65, 1.68, 0.72, 0.57 and 1.38, respectively. In vitro skin decontamination experiments coupled with a dermal absorption study demonstrated that DDGel can efficiently remove chemicals from skin surface, back-extract from the SC, and significantly reduced chemical penetration into skin or systemic absorption for all six simulants tested. Therefore, DDGel offers a great potential as a NextGen skin Decon platform technology for both military and civilian use. Copyright © 2018 John Wiley & Sons, Ltd.

  10. Dilute chemical decontamination resins and the mixed waste issue

    International Nuclear Information System (INIS)

    Denault, R.P.; Hallman, J.T.

    1988-01-01

    The decontamination of reactor primary systems, sub-systems and components is an important method used to reduce the occupational radiation exposure of nuclear plant personnel. The waste produced by the application of this technology is mainly solid in the form of ion exchange resins. As a result of a recent agreement between the Environmental Protection Agency (EPA) and the Nuclear Regulatory Commission (NRC), all radioactive waste must meet EPA burial criteria. The chemicals used in a decontamination and certain metals dissolved during the process, primarily chromium, could render the waste hazardous as well as radioactive or more commonly called a mixed waste. This paper defines mixed waste as described in the EPA directive 9432.00-2, and examine the criteria by which waste is categorized as hazardous. The decontamination waste resin generated by two processes, the CAN-DEREM and the LOMI process, is described in detail. Waste data obtained from decontaminations performed by LN Technologies Corporation including chemical, metal and radionuclide loadings on resins from both PWR and BWR applications are presented

  11. Chemical decontamination method for radioactive metal waste

    International Nuclear Information System (INIS)

    Onuma, Tsutomu; Tanaka, Akio; Shibuya, Sadao.

    1991-01-01

    When contaminants mainly composed of copper remained on the surface of stainless steel wastes sent from an electrolytic reduction as a first step are chemically decontaminated, metal wastes are discriminated to carbon steel wastes and stainless steel wastes. Then, the carbon steel wastes are applied only with the first step of immersing in a sulfuric acid solution, and stainless steel wastes are applied with a first step of immersing into a sulfuric acid solution for electrolytic reduction for a predetermined period of time and a second step of immersing into a liquid in which an oxidative metal salt is added to sulfuric acid. The decontamination liquid which is used for immersing the stainless steel wastes in the second step and the oxidation force of which is lowered is used as the sulfuric acid solution in the first step for the carbon steel wastes. In view of the above, the decontamination liquid of the second step can be utilized most effectively, enabling to greatly decrease the secondary wastes and to improve decontamination efficiency. (T.M.)

  12. Method of heat decomposition for chemical decontaminating resin waste

    International Nuclear Information System (INIS)

    Kikuchi, Akira.

    1988-01-01

    Purpose: To make resin wastes into non-deleterious state, discharge them into a resin waste storage tank of existent radioactive waste processing facility and store and dispose them. Constitution: In the processing of chemical decontaminating resin wastes, iron exchange resins adsorbing chemical decontaminating agents comprising a solution of citric acid, oxalic acid, formic acid and EDTA alone or as a mixture of them are heated to dry, thermally decomposed and then separated from the ion exchange resins. That is, the main ingredients of the chemical decontaminating agents are heat-decomposed when heated and dried at about 250 deg C in air and converted into non-toxic gases such as CO, CO 2 , NO, NO 2 or H 2 O. Further, since combustion or carbonization of the basic materials for the resin is not caused at such a level of temperature, the resin wastes removed with organic acid and chelating agents are transferred to an existent resin waste storage tank and stored therein. In this way, facility cost and radiation exposure can remarkably be decreased. (Kamimura, M.)

  13. Technical area status report for chemical/physical treatment

    International Nuclear Information System (INIS)

    Brown, C.H. Jr.; Schwinkendorf, W.E.

    1993-08-01

    These Appendices describe various technologies that may be applicable to the Mixed Waste Treatment Plant (MWTP) Chemical/Physical Treatment System (CPTS). These technologies were identified by the CPTS Technical Support Group (TSG) as potentially applicable to a variety of separation, volume reduction, and decontamination requirements. The purpose was to identify all available and developing technologies, and their characteristics, for subsequent evaluation for specific requirements identified for the CPTS. However, the technologies described herein are not necessarily all inclusive, nor are they necessarily all applicable

  14. Chemical decontamination of metals

    International Nuclear Information System (INIS)

    Partridge, J.A.; Lerch, R.E.

    1979-10-01

    A metal decontamination process based upon removal of contamination by treatment with a cerium (IV)-nitric acid solution (or other redox agent in nitric acid) is feasible and highly promising. The technique is effective in dissolving the surface layer of stainless steel. Dissolution rates of approximately 1.5 mils/h were demonstrated with cerium (IV)-nitric acid solutions. Removal of plutonium contamination from stainless steel was demonstrated in laboratory tests, in which activity levels were reduced from greater than 5 x 10 5 counts per minute to nondetectable levels in approximately one hour at 90 0 C. Removal of paint from stainless steel surfaces was also demonstrated. Advantages of this process over other chemical solutions include: (1) The solutions are not high salt systems; therefore, there is potentially less waste generated. (2) Cerium(IV) in nitric acid is a good dissolution agent for plutonium oxide. (3) Regeneration of Ce(IV) during the decontamination is accomplished by electrolysis. (4) The process should be effective for irregularly shaped equipment. (5) It could be effective as a spray or a flow-through system. 13 figures

  15. Testing and comparison of seventeen decontamination chemicals

    International Nuclear Information System (INIS)

    Demmer, R.L.

    1996-09-01

    This report details the testing and evaluation of seventeen decontamination chemicals. Tests were conducted with SIMCON (simulated contamination) coupons under controlled conditions to compare cleaning effectiveness, overall corrosion potential for plant equipment, interim waste generation and final waste generation

  16. Experience Practices on Decontamination Activity in NPP Decommissioning

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Suk Bon; Kim, Jeongju; Sohn, Wook [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2016-10-15

    Decommissioning of a nuclear power plant (NPP) involves various technical and administrative activities for a utility to terminate its license, which allows the plant site to be released from the regulatory control (site release). Decontamination activity in NPP decommissioning is one of the main technical activities to be performed during the decommissioning. The decontamination at decommissioning sites is usually performed due to several reasons such as reducing personnel dose and disposal costs, and cleanup to meet license termination requirements by using physical or chemical removal techniques proven through the previous experience practices. This paper introduces the best and worst practices for the decontamination activities collected from the decommissioning operational experiences through the implementation of nuclear decommissioning projects around the world. Review of the experiences of decontamination shows that it is important to conduct an advanced planning for optimized implementation of decontamination taking into considering site specific conditions such as operating time, reactor type, system, and so on. Also, a review of newer decontamination methods is necessary to safely and economically decommission the nuclear facility.

  17. Chemical decontamination and melt densification of chop-leach fuel hulls

    International Nuclear Information System (INIS)

    Dillon, R.L.; Griggs, B.; Kemper, R.S.; Nelson, R.G.

    1976-01-01

    This paper reports on decontamination and densification studies of chop-leach fuel hull residues designed to minimize the transuranic element (TRU) contaminated waste stream. Decontamination requirements have been established from studies of TRU element distribution in the fuel hull residues. Effective surface decontamination of Zircaloy requires removal of zirconium oxide corrosion products. Good decontamination factors have been achieved with aqueous solutions following high temperature HF conditioning of oxide films. Molten fluoride salt mixtures are effective decontaminants, but pose problems in metal loss and salt dragout. Molten metal decontamination methods are highly preliminary, but may be required to reduce TRU originating from tramp uranium in Zircaloy. Low melting (1300 0 C) alloy of Zircaloy, stainless steel, and Inconel have been prepared in induction heated graphite crucibles. High quality ingots of Zircaloy-2 have been prepared directly from short sections of descaled fuel clad tubing using the Inductoslag process. This material is readily capable of refabrication. Inductoslag melts have also been prepared from heavily oxidized Zircaloy tubing demonstrating melt densification without prior decontamination is technically feasible. Hydrogen absorption kinetics have been demonstrated with cast Zircaloy-2 and cast Zircaloy-stainless steel-Inconel alloys. Metallic fuel hull residues have been proposed as a storage medium for tritium released from fuel during reprocessing. (author)

  18. Comparison of Selected Methods for Individual Decontamination of Chemical Warfare Agents

    OpenAIRE

    Tomas Capoun; Jana Krykorkova

    2014-01-01

    This study addresses the individual decontamination of chemical warfare agents (CWA) and other hazardous substances. The individual decontamination applies to contaminated body surfaces, protective clothing and objects immediately after contamination, performed individually or by mutual assistance using prescribed or improvised devices. The article evaluates the importance of individual decontamination, security level for Fire and Rescue Service Units of the Czech Republic (FRS CR) and demons...

  19. Decontamination by water jet, chemical and electrochemical methods

    International Nuclear Information System (INIS)

    Gauchon, J.P.; Mordenti, P.; Bezia, C.; Fuentes, P.; Kervegant, Y.; Munoz, C.; Pierlas, C.

    1986-01-01

    The decontamination tests have been carried out on samples coming from representative specimens from primary circuit of the PWR and on samples coming from the emergency feed water piping of the German BWR (Isar). The oxide found in PWR primary loops can only be removed by a two steps process. The initial embrittling step is particularly effective in hot alkaline permanganate medium. Oxidation by ozone treatment is less effective. The second step involves chemical erosion of the metal in nitrofluoric acid in conjonction with ultrasonic agitation. Among the reagents used, only oxalic acid is suitable for electrolytic decontamination. Among the reagents possible for decontamination of the Isar specimens (ferritic steel lined with hematite) halogenous acid in mixture without or with oxygenated water, sulfuric acid, the formic acid/formaldehyde mixture are chosen. Metal erosion with high pressure jet as well as the decontamination efficiency on parts lined with hematite have made possible to determine the best conditions. 33 figs, 29 refs

  20. Evaluation of commercially available decontamination chemicals

    International Nuclear Information System (INIS)

    Shurte, E.A.; Rankin, W.N.

    1988-01-01

    The effectiveness of commercially available decontamination solutions was compared with the effectiveness of 10% oxalic acid in controlled laboratory tests. Type 304L stainless steel and Inconel 625 specimens were used. Contamination was sludge from Savannah River Plant (SRP) high level waste tanks. Measured amounts of contamination were placed on each specimen. They were then heated to bond the contamination to the surface and cleaned according to the manufacturer's directions. The effectiveness of the product was determined by monitoring specimens before and after cleaning. Four of the 16 solutions evaluated removed all the contamination from Type 304L stainless steel. Inconel 625 was more difficult to decontaminate. Further tests are planned with the chemicals that were most effective in this test. 4 refs., 6 tabs

  1. Evaluation of commercially available decontamination chemicals

    International Nuclear Information System (INIS)

    Shurte, E.A.

    1988-01-01

    The effectiveness of commercially available decontamination solutions was compared with the effectiveness of 10% oxalic acid in controlled lab. tests. Type 304L stainless steel and Inconel 625 specimens were used. Contamination was sludge from Savannah River Plant (SRP) high level waste tanks. Measured amounts of contamination were placed on each specimen. They were then heated to bond the contamination to the surface and cleaned according to the manufacturer's directions. The effectiveness of the produce was determined by monitoring specimens before and after cleaning. Four of the 16 solutions evaluated removed all the contamination from Type 304L stainless steel. Inconel 625 was more difficult to decontaminate. Further tests are planned with the chemicals that were most effective in this test

  2. Method of chemical decontamination of stainless steel

    International Nuclear Information System (INIS)

    Onuma, Tsutomu; Akimoto, Hidetoshi.

    1989-01-01

    The present invention concerns a decontamination method of chemically decontaminating radioactive metal wastes of passivated stainless steels to a radioactivity level identical with usual wastes, in which the amount of oxidizable metal salts used is decreased. Metal wastes of stainless steels contaminated at their surface with radioactive materials are immersed in a sulfuric acid solution. In this case, a voltage is applied for a certain period of time so that the potential of the stainless steels comes to an active region. Then, oxidizable metal salt (tetravalent cerium) is added into the sulfuric acid solution. According to this method, since most of radioactive materials are removed in the immersing step to the sulfuric acid solution, the amount of the tetravalent cerium used is as less as 1/700 and the decontamination time is as short as 1/4 as compared with those in the conventional method. (K.M.)

  3. [Decontamination of chemical warfare agents by photocatalysis].

    Science.gov (United States)

    Hirakawa, Tsutomu; Mera, Nobuaki; Sano, Taizo; Negishi, Nobuaki; Takeuchi, Koji

    2009-01-01

    Photocatalysis has been widely applied to solar-energy conversion and environmental purification. Photocatalyst, typically titanium dioxide (TiO(2)), produces active oxygen species under irradiation of ultraviolet light, and can decompose not only conventional pollutants but also different types of hazardous substances at mild conditions. We have recently started the study of photocatalytic decontamination of chemical warfare agents (CWAs) under collaboration with the National Research Institute of Police Science. This article reviews environmental applications of semiconductor photocatalysis, decontamination methods for CWAs, and previous photocatalytic studies applied to CWA degradation, together with some of our results obtained with CWAs and their simulant compounds. The data indicate that photocatalysis, which may not always give a striking power, certainly helps detoxification of such hazardous compounds. Unfortunately, there are not enough data obtained with real CWAs due to the difficulty in handling. We will add more scientific data using CWAs in the near future to develop useful decontamination systems that can reduce the damage caused by possible terrorism.

  4. Chemical decontamination method for radioactive metal waste

    International Nuclear Information System (INIS)

    Tanaka, Akio; Onuma, Tsutomu; Yamazaki, Sei; Miura, Haruki.

    1993-01-01

    The present invention provides a chemical decontamination method for radioactive metal wastes, which are generated from radioactive material handling facilities and the surfaces of which are contaminated by radioactive materials. That is, it has a feature of applying acid dissolution simultaneously with mechanical grinding. The radioactive metal wastes are contained in a vessel such as a barrel together with abrasives in a sulfuric acid solution and rotated at several tens rotation per minute. By such procedures for the radioactive metal wastes, (1) cruds and passive membranes are mechanically removed, (2) exposed mother metal materials are uniformly brought into contact with sulfuric acid and further (3) the mother metal materials dissolve the cruds and the passive membranes also chemically by a reducing dissolution (so-called local cell effect). According to the method of the present invention, stainless steel metal wastes having cruds and passive membranes can rapidly and efficiently be decontaminated to a radiation level equal with that of ordinary wastes. (I.S.)

  5. Decontamination of chemical agents from drinking water infrastructure: a literature review and summary.

    Science.gov (United States)

    Szabo, Jeff; Minamyer, Scott

    2014-11-01

    This report summarizes the current state of knowledge on the persistence of chemical contamination on drinking water infrastructure (such as pipes) along with information on decontamination should persistence occur. Decontamination options for drinking water infrastructure have been explored for some chemical contaminants, but important data gaps remain. In general, data on chemical persistence on drinking water infrastructure is available for inorganics such as arsenic and mercury, as well as select organics such as petroleum products, pesticides and rodenticides. Data specific to chemical warfare agents and pharmaceuticals was not found and data on toxins is scant. Future research suggestions focus on expanding the available chemical persistence data to other common drinking water infrastructure materials. Decontaminating agents that successfully removed persistent contamination from one infrastructure material should be used in further studies. Methods for sampling or extracting chemical agents from water infrastructure surfaces are needed. Published by Elsevier Ltd.

  6. Chemical decontamination method for radioactive metal waste

    International Nuclear Information System (INIS)

    Onuma, Tsutomu; Akimoto, Hidetoshi

    1991-01-01

    The invention relates to a decontamination method for radioactive metal waste products derived from equipment that handles radioactive materials whose surfaces have been contaminated; in particular it concerns a decontamination method that reduces the amount of radioactive waste by decontaminating radioactive waste substances to a level of radioactivity in line with normal waste products. In order to apply chemical decontamination to metal waste products whose surfaces are divided into carbon steel waste and stainless steel waste; the carbon steel waste is treated using only a primary process in which the waste is immersed in a sulfuric acid solution, while the stainless steel waste must be treated with both the primary process and then electrolytically reduces it for a specific length of time and a secondary process that uses a solution of sulfuric acid mixed with oxidizing metal salts. The method used to categorize metal waste into carbon steel waste and stainless steel waste involves determining the presence, or absence, of magnetism. Voltage is applied for a fixed duration; once that has stopped, electrolytic reduction repeats the operative cycle of applying, then stopping voltage until the potential of the radioactive metal waste is retained in the active region. 1 fig. 2 tabs

  7. Next Generation Non-particulate Dry Nonwoven Pad for Chemical Warfare Agent Decontamination

    Energy Technology Data Exchange (ETDEWEB)

    Ramkumar, S S; Love, A; Sata, U R; Koester, C J; Smith, W J; Keating, G A; Hobbs, L; Cox, S B; Lagna, W M; Kendall, R J

    2008-05-01

    New, non-particulate decontamination materials promise to reduce both military and civilian casualties by enabling individuals to decontaminate themselves and their equipment within minutes of exposure to chemical warfare agents or other toxic materials. One of the most promising new materials has been developed using a needlepunching nonwoven process to construct a novel and non-particulate composite fabric of multiple layers, including an inner layer of activated carbon fabric, which is well-suited for the decontamination of both personnel and equipment. This paper describes the development of a composite nonwoven pad and compares efficacy test results for this pad with results from testing other decontamination systems. The efficacy of the dry nonwoven fabric pad was demonstrated specifically for decontamination of the chemical warfare blister agent bis(2-chloroethyl)sulfide (H or sulfur mustard). GC/MS results indicate that the composite fabric was capable of significantly reducing the vapor hazard from mustard liquid absorbed into the nonwoven dry fabric pad. The mustard adsorption efficiency of the nonwoven pad was significantly higher than particulate activated carbon (p=0.041) and was similar to the currently fielded US military M291 kit (p=0.952). The nonwoven pad has several advantages over other materials, especially its non-particulate, yet flexible, construction. This composite fabric was also shown to be chemically compatible with potential toxic and hazardous liquids, which span a range of hydrophilic and hydrophobic chemicals, including a concentrated acid, an organic solvent and a mild oxidant, bleach.

  8. Experience with dilute chemical decontamination in Indian Pressurized Heavy Water Reactors

    International Nuclear Information System (INIS)

    Velmurugan, S.; Rufus, A.L.; Sathyaseelan, V.S.; Subramanian, Veena; Mittal, V.K.; Narasimhan, S.V.

    2010-01-01

    Dilute Chemical Decontamination (DCD) process has been used in several full system and components of nuclear coolant systems to effectively remove the radioactive contaminants that causes radiation field and consequent MANREM problem. The DCD process uses chemicals in very low concentrations (millimolar) and dissolves the oxide film along with the activity incorporated in the oxide film. In DCD process operated under the regenerative mode, the chemical formulation spent in the process of oxide dissolution is replenished by passing through cation exchange columns. Finally, after achieving sufficient decontamination of the system/component, the added decontamination chemicals along with the activities and metal ions released during the process are removed by mixed bed ion exchange columns and the system is restored to normal operating condition in few days time. In PHWRs, the regenerative DCD process is applied for full primary coolant system decontamination. The chemicals are added directly to the heavy water coolant with the fuel in the core. In Indian PHWRs (MAPS-1 and 2, RAPS-1 and 2, NAPS-1 and 2 and KAPS-1), the process has been applied eleven times. A chemical formulation based on NTA, Citric acid and Ascorbic acid has been applied seven times with good results. Decontamination factors in the range 2-30 have been obtained in different components with good MANREM savings in the subsequent maintenance works. Efforts are on to modify the process to take care of the challenges posed by antimony isotope. An inhibitor (Rodine-92B) based process was successfully tested in NAPS-2 for removing antimony isotopes ( 122 Sb and 124 Sb). Further refining of the antimony removal process is being worked out. Similarly, the process is being modified to effectively remove the hotspot causing stellite particles in the moderator system of PHWRs. A permanganate based process has been developed and tested in several adjustor rod drive mechanisms in KAPS and NAPS. The experience of

  9. Chemical cleaning, decontamination and corrosion

    International Nuclear Information System (INIS)

    Gadiyar, H.S.; Das Chintamani; Gaonkar, K.B.

    1991-01-01

    Chemical cleaning of process equipments and pipings in chemical/petrochemical industries is necessitated for improving operation, for preventing premature failures and for avoiding contamination. In developing a chemical formulation for cleaning equipments, the important aspects to be considered include (i) effective removal of corrosion products and scales, (ii) minimum corrosion of the base metal, (iii) easy to handle chemicals and (iv) economic viability. As on date, a wide variety of chemical formulations are available, many of them are either proprietory or patented. For evolving an effective formulation, knowledge of the oxides of various metals and alloys on the one hand and acid concentration, complexing agents and inhibitors to be incorporated on the other, is quite essential. Organic acids like citric acid, acetic acid and formic acid are more popular ones, often used with EDTA for effective removal of corrosion products from ferrous components. The report enumerates some of the concepts in developing effective formulations for chemical cleaning of carbon steel components and further, makes an attempt to suggest simple formulations to be developed for chemical decontamination. (author). 6 refs., 3 fi gs., 4 tabs

  10. Criteria for the evaluation of a dilute decontamination demonstration

    International Nuclear Information System (INIS)

    FitzPatrick, V.F.; Divine, J.R.; Hoenes, G.R.; Munson, L.F.; Card, C.J.

    1981-12-01

    This document provides the prerequisite technical information required to evaluate and/or develop a project to demonstrate the dilute chemical decontamination of the primary coolant system of light water reactors. The document focuses on five key areas: the basis for establishing programmatic prerequisites and the key decision points that are required for proposal evaluation and/or RFP (Request for Proposal) issuance; a technical review of the state-of-the-art to identify the potential impacts of a reactor's primary-system decontamination on typical BWR and PWR plants; a discussion of the licensing, recertification, fuel warranty, and institutional considerations and processes; a preliminary identification and development of the selection criteria for the reactor and the decontamination process; and a preliminary identification of further research and development that might be required

  11. Chemical warfare agent simulants for human volunteer trials of emergency decontamination: A systematic review.

    Science.gov (United States)

    James, Thomas; Wyke, Stacey; Marczylo, Tim; Collins, Samuel; Gaulton, Tom; Foxall, Kerry; Amlôt, Richard; Duarte-Davidson, Raquel

    2018-01-01

    Incidents involving the release of chemical agents can pose significant risks to public health. In such an event, emergency decontamination of affected casualties may need to be undertaken to reduce injury and possible loss of life. To ensure these methods are effective, human volunteer trials (HVTs) of decontamination protocols, using simulant contaminants, have been conducted. Simulants must be used to mimic the physicochemical properties of more harmful chemicals, while remaining non-toxic at the dose applied. This review focuses on studies that employed chemical warfare agent simulants in decontamination contexts, to identify those simulants most suitable for use in HVTs of emergency decontamination. Twenty-two simulants were identified, of which 17 were determined unsuitable for use in HVTs. The remaining simulants (n = 5) were further scrutinized for potential suitability according to toxicity, physicochemical properties and similarities to their equivalent toxic counterparts. Three suitable simulants, for use in HVTs were identified; methyl salicylate (simulant for sulphur mustard), diethyl malonate (simulant for soman) and malathion (simulant for VX or toxic industrial chemicals). All have been safely used in previous HVTs, and have a range of physicochemical properties that would allow useful inference to more toxic chemicals when employed in future studies of emergency decontamination systems. © 2017 Crown Copyright. Journal of Applied Toxicology published by John Wiley & Sons, Ltd.

  12. Decontamination of nuclear facilities

    International Nuclear Information System (INIS)

    1982-01-01

    Thirty-seven papers were presented at this conference in five sessions. Topics covered include regulation, control and consequences of decontamination; decontamination of components and facilities; chemical and non-chemical methods of decontamination; and TMI decontamination experience

  13. How Clean is Safe? Improving the Effectiveness of Decontamination of Structures and People Following Chemical and Biological Incidents

    Energy Technology Data Exchange (ETDEWEB)

    Vogt (Sorensen), B.M.

    2003-04-03

    This report describes a U.S. Department of Energy, (DOE) Chemical and Biological National Security Program project that sought to establish what is known about decontamination of structures, objects, and people following an exposure to chemical or biological materials. Specifically we sought to identify the procedures and protocols used to determine when and how people or buildings are considered ''clean'' following decontamination. To fulfill this objective, the study systematically examined reported decontamination experiences to determine what procedures and protocols are currently employed for decontamination, the timeframe involved to initiate and complete the decontamination process, how the contaminants were identified, the factors determining when people were (or were not) decontaminated, the problems encountered during the decontamination process, how response efforts of agencies were coordinated, and the perceived social psychological effects on people who were decontaminated or who participated in the decontamination process. Findings and recommendations from the study are intended to aid decision-making and to improve the basis for determining appropriate decontamination protocols for recovery planners and policy makers for responding to chemical and biological events.

  14. Demonstration and evaluation of the CORPEX trademark Nuclear Decontamination Process, Technical task plan No. SR152005. Final Report

    International Nuclear Information System (INIS)

    May, C.G.

    1997-01-01

    In June, 1995, the Decontamination and Decommissioning Focus Area funded a demonstration of the CORPEX Nuclear Decontamination Process in an Old Metallography Laboratory glovebox at the Savannah River Site. The objective of the demonstration was to prove the effectiveness of a new and innovative technology that would reduce the risks associated with future cleanups of plutonium-238 contaminated equipment in the DOE complex. After facility and vendor preparations in support of the demonstration, Westinghouse Savannah River Company (WSRC) was informed by the vendor that the chemistry proposed for use in the decontamination process was not effective on sintered plutonium, which was the form of plutonium in the selected glovebox. After further technical evaluation, the demonstration was canceled. This report describes the work performed in support of the demonstration and the present status of the project. The CORPEX chemical process is a nondestructive cleaning method that removes only the contaminant and the matrix that fixed the contaminant to the surface. It does not damage the substrate. The cleaning agent is destroyed by the addition of proprietary oxidizers, leaving water, carbon dioxide and nitrogen gases, and a sludge as waste

  15. Comparison of Selected Methods for Individual Decontamination of Chemical Warfare Agents

    Directory of Open Access Journals (Sweden)

    Tomas Capoun

    2014-06-01

    Full Text Available This study addresses the individual decontamination of chemical warfare agents (CWA and other hazardous substances. The individual decontamination applies to contaminated body surfaces, protective clothing and objects immediately after contamination, performed individually or by mutual assistance using prescribed or improvised devices. The article evaluates the importance of individual decontamination, security level for Fire and Rescue Service Units of the Czech Republic (FRS CR and demonstrates some of the devices. The decontamination efficiency of selected methods (sorbent, glove and sponge, two-chamber foam device and wiping with alcohol was evaluated for protective clothing and painted steel plate contaminated with O-ethyl-S-(diisopropylaminoethyl-methylthiophosphonate (VX, sulfur mustard, o-cresol and acrylonitrile. The methods were assessed from an economic point of view and with regard to specific user parameters, such as the decontamination of surfaces or materials with poor accessibility and vertical surfaces, the need for a water rinse as well as toxic waste and its disposal.

  16. Oxidative decontamination of chemical and biological warfare agents using L-Gel.

    Science.gov (United States)

    Raber, Ellen; McGuire, Raymond

    2002-08-05

    A decontamination method has been developed using a single reagent that is effective both against chemical warfare (CW) and biological warfare (BW) agents. The new reagent, "L-Gel", consists of an aqueous solution of a mild commercial oxidizer, Oxone, together with a commercial fumed silica gelling agent, Cab-O-Sil EH-5. L-Gel is non-toxic, environmentally friendly, relatively non-corrosive, maximizes contact time because of its thixotropic nature, clings to walls and ceilings, and does not harm carpets or painted surfaces. The new reagent also addresses the most demanding requirements for decontamination in the civilian sector, including availability, low maintenance, ease of application and deployment by a variety of dispersal mechanisms, minimal training and acceptable expense. Experiments to test the effectiveness of L-Gel were conducted at Lawrence Livermore National Laboratory and independently at four other locations. L-Gel was tested against all classes of chemical warfare agents and against various biological warfare agent surrogates, including spore-forming bacteria and non-virulent strains of real biological agents. Testing showed that L-Gel is as effective against chemical agents and biological materials, including spores, as the best military decontaminants.

  17. Technical area status report for chemical/physical treatment. Volume 2, Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Brown, C.H. Jr. [Oak Ridge National Lab., TN (United States); Schwinkendorf, W.E. [BDM Federal, Inc., Arlington, VA (United States)

    1993-08-01

    These Appendices describe various technologies that may be applicable to the Mixed Waste Treatment Plant (MWTP) Chemical/Physical Treatment System (CPTS). These technologies were identified by the CPTS Technical Support Group (TSG) as potentially applicable to a variety of separation, volume reduction, and decontamination requirements. The purpose was to identify all available and developing technologies, and their characteristics, for subsequent evaluation for specific requirements identified for the CPTS. However, the technologies described herein are not necessarily all inclusive, nor are they necessarily all applicable.

  18. Development of haemostatic decontaminants for the treatment of wounds contaminated with chemical warfare agents. 2: evaluation of in vitro topical decontamination efficacy using undamaged skin.

    Science.gov (United States)

    Dalton, Christopher H; Hall, Charlotte A; Lydon, Helen L; Chipman, J K; Graham, John S; Jenner, John; Chilcott, Robert P

    2015-05-01

    The risk of penetrating, traumatic injury occurring in a chemically contaminated environment cannot be discounted. Should a traumatic injury be contaminated with a chemical warfare (CW) agent, it is likely that standard haemostatic treatment options would be complicated by the need to decontaminate the wound milieu. Thus, there is a need to develop haemostatic products that can simultaneously arrest haemorrhage and decontaminate CW agents. The purpose of this study was to evaluate a number of candidate haemostats for efficacy as skin decontaminants against three CW agents (soman, VX and sulphur mustard) using an in vitro diffusion cell containing undamaged pig skin. One haemostatic product (WoundStat™) was shown to be as effective as the standard military decontaminants Fuller's earth and M291 for the decontamination of all three CW agents. The most effective haemostatic agents were powder-based and use fluid absorption as a mechanism of action to sequester CW agent (akin to the decontaminant Fuller's earth). The envisaged use of haemostatic decontaminants would be to decontaminate from within wounds and from damaged skin. Therefore, WoundStat™ should be subject to further evaluation using an in vitro model of damaged skin. Copyright © 2014 Crown copyright. Journal of Applied Toxicology © 2014 John Wiley & Sons, Ltd.

  19. Efficacy of liquid and foam decontamination technologies for chemical warfare agents on indoor surfaces.

    Science.gov (United States)

    Love, Adam H; Bailey, Christopher G; Hanna, M Leslie; Hok, Saphon; Vu, Alex K; Reutter, Dennis J; Raber, Ellen

    2011-11-30

    Bench-scale testing was used to evaluate the efficacy of four decontamination formulations on typical indoor surfaces following exposure to the liquid chemical warfare agents sarin (GB), soman (GD), sulfur mustard (HD), and VX. Residual surface contamination on coupons was periodically measured for up to 24h after applying one of four selected decontamination technologies [0.5% bleach solution with trisodium phosphate, Allen Vanguard Surface Decontamination Foam (SDF™), U.S. military Decon Green™, and Modec Inc. and EnviroFoam Technologies Sandia Decontamination Foam (DF-200)]. All decontamination technologies tested, except for the bleach solution, performed well on nonporous and nonpermeable glass and stainless-steel surfaces. However, chemical agent residual contamination typically remained on porous and permeable surfaces, especially for the more persistent agents, HD and VX. Solvent-based Decon Green™ performed better than aqueous-based bleach or foams on polymeric surfaces, possibly because the solvent is able to penetrate the polymer matrix. Bleach and foams out-performed Decon Green for penetrating the highly polar concrete surface. Results suggest that the different characteristics needed for an ideal and universal decontamination technology may be incompatible in a single formulation and a strategy for decontaminating a complex facility will require a range of technologies. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Systematic chemical decontamination using IF7 gas - 59036

    International Nuclear Information System (INIS)

    Hata, Haruhi; Yokoyama, Kaoru; Sugitsue, Noritake

    2012-01-01

    Since 1979, Uranium enrichment technology has been researched through the gas centrifuge method, at Ningyo-toge Environmental Engineering Center of Japan Atomic Energy Agency (JAEA). In addition, the Demonstration Plant, that is final stage test facilities, was operating continuously from 1988 to 2001. As a result, a lot of residues accumulated in the plant. Most of this accumulation was found be uranium intermediate fluoride. The basic decommission policy of JAEA is that equipments of gas centrifuge will be decontaminated by sulfuric acid immersion method for clearance and reuse. In our plan, approximately 90% of metals will be cleared and reused, and then the remaining 10% will be disposed of radioactive waste. We propose a combination of sulfuric acid immersion method and the systematic chemical decontamination as an efficient method for decontamination of uranium enrichment facilities. This paper focuses on the method and performance of systematic chemical decontamination using IF 7 gas. The following (Figure 1) shows our decommission policy and position of systematic chemical decontamination by IF 7 gas for uranium enrichment plant. The IF 7 treatment technique belongs to the systematic decontamination technology. It has the high performance decontamination technique for the plant that accumulates the uranium intermediate fluoride, such as UF 4 , UF 5 , U 2 F 9 , and U 4 F 17 , which exist in the uranium enrichment plant through the Gas Centrifuge, called GCF. The one of characteristics of the IF 7 treatment, the secondary waste is just an IF 5 and little residues. In addition, this IF 5 can be reused as materials for making new IF 7 gas. The IF 7 treatment can also be performed in the room temperature and very low pressure like a 10-45 hPa. Furthermore, the IF 7 treatment is a simple method using chemical reaction. For this reason, we hardly need to care about secondary reaction with the exception of the reaction with IF 7 gasand the uranium intermediate

  1. Chemical warfare agent simulants for human volunteer trials of emergency decontamination: A systematic review

    OpenAIRE

    James, Thomas; Wyke, Stacey; Marczylo, Tim; Collins, Samuel; Gaulton, Tom; Foxall, Kerry; Amlôt, Richard; Duarte‐Davidson, Raquel

    2017-01-01

    Abstract Incidents involving the release of chemical agents can pose significant risks to public health. In such an event, emergency decontamination of affected casualties may need to be undertaken to reduce injury and possible loss of life. To ensure these methods are effective, human volunteer trials (HVTs) of decontamination protocols, using simulant contaminants, have been conducted. Simulants must be used to mimic the physicochemical properties of more harmful chemicals, while remaining ...

  2. Dresden Nuclear Power Station, Unit No. 1: Primary cooling system chemical decontamination: Draft environmental statement (Docket No. 50-10)

    International Nuclear Information System (INIS)

    1980-05-01

    The staff has considered the environmental impact and economic costs of the proposed primary cooling system chemical decontamination at Dresden Nuclear Power Station, Unit 1. The staff has focused this statement on the occupational radiation exposure associated with the proposed Unit 1 decontamination program, on alternatives to chemical decontamination, and on the environmental impact of the disposal of the solid radioactive waste generated by this decontamination. The staff has concluded that the proposed decontamination will not significantly affect the quality of the human environment. Furthermore, any impacts from the decontamination program are outweighed by its benefits. 2 figs., 7 tabs

  3. Decontamination of FAST (CPP-666) fuel storage area stainless steel fuel storage racks

    International Nuclear Information System (INIS)

    Kessinger, G.F.

    1993-10-01

    The purpose of this report was to identify and evaluate alternatives for the decontamination of the RSM stainless steel that will be removed from the Idaho Chemical Processing plant (ICPP) fuel storage area (FSA) located in the FAST (CPP-666) building, and to recommend decontamination alternatives for treating this material. Upon the completion of a literature search, the review of the pertinent literature, and based on the review of a variety of chemical, mechanical, and compound (both chemical and mechanical) decontamination techniques, the preliminary results of analyses of FSA critically barrier contaminants, and the data collected during the FSA Reracking project, it was concluded that decontamination and beneficial recycle of the FSA stainless steel produced is technically feasible and likely to be cost effective as compared to burying the material at the RWMC. It is recommended that an organic acid, or commercial product containing an organic acid, be used to decontaminate the FSA stainless steel; however, it is also recommended that other surface decontamination methods be tested in the event that this method proves unsuitable. Among the techniques that should be investigated are mechanical techniques (CO 2 pellet blasting and ultra-high pressure water blasting) and chemical techniques that are compatible with present ICPP waste streams

  4. Evaluation of a dilute chemical decontaminant for pressurized heavy water reactors

    International Nuclear Information System (INIS)

    Velmurugan, S.; Narasimhan, S.V.; Mathur, P.K.; Venkateswarlu, K.S.

    1991-01-01

    In this paper a dilute chemical decontamination formulation based on ethylene diamine tetraacetic acid, oxalic acid, and citric acid is evaluated for its efficacy in removing oxide layers in a pressurized heavy water reactor (PHWR). An ion exchange system that is specifically suited for fission product-dominated contamination in a PHWR is suggested for the reagent regeneration stage of the decontamination process. An attempt has been made to understand the redeposition behavior of various isotopes during the decontamination process. The polarographic method of identifying the species formed in the dissolution process is explained. Electrochemical measurements are employed to follow the course of oxide removal during the dissolution process. Scanning electron micrographs of metal coupons before and after the dissolution process exemplify the involvement of base metal in the formation of a ferrous oxalate layer. Material compatibility tests between the decontaminant and carbon steel, Monel-400, and Zircaloy-2 are reported

  5. Decontamination of radioactively contaminated surfaces - Method for testing and assessing the ease of decontamination (International Standard Publication ISO 8690:1988)

    International Nuclear Information System (INIS)

    Stefanik, J.

    2001-01-01

    The specifications laid down in this International Standard apply to the testing of surfaces which may become contaminated by radioactive materials. Decontaminability data obtained using this test method are not applicable to technical systems where layers of contaminating materials are formed as a result of long-term application of higher temperatures and pressures (for example primary circuits of nuclear reactors). The purpose of the test is to assess the ease of decontamination of surfaces under laboratory conditions. In practical applications, it may be important to consider other qualities, such as chemical, mechanical and radiation resistance and long-term stability in the selection of the materials to be used. It should be recognized that further decontamination tests under simulated service conditions may be needed

  6. Pilot-scale decontamination solution test results HGTP-93-0702-02

    International Nuclear Information System (INIS)

    Clemmer, R.G.; Allen, R.P.; Bagaasen, L.M.; Fetrow, L.K.

    1993-05-01

    Decontamination solution testing constitutes a task of the Hanford Grout Technology Program (HGTP) at Pacific Northwest Laboratory (PNL). The HGTP provides technical support to the Westinghouse Hanford Company (WHC) Grout Disposal Program. Cementitious grout has been identified as the waste form for low-level radioactive waste. Grout processing equipment, including mixers, pumps, and piping, will require periodic maintenance. Decontamination of components is needed to reduce radiation dose to maintenance workers. The purpose of this work was to develop and test methods for decontaminating grout processing equipment. The proposed method of decontamination is to use a mild chemical solution, such as a 6 N citric acid to dissolve the grout. The method should effectively remove grout without causing degradation of grout processing equipment

  7. Reactive decontamination formulation

    Science.gov (United States)

    Giletto, Anthony [College Station, TX; White, William [College Station, TX; Cisar, Alan J [Cypress, TX; Hitchens, G Duncan [Bryan, TX; Fyffe, James [Bryan, TX

    2003-05-27

    The present invention provides a universal decontamination formulation and method for detoxifying chemical warfare agents (CWA's) and biological warfare agents (BWA's) without producing any toxic by-products, as well as, decontaminating surfaces that have come into contact with these agents. The formulation includes a sorbent material or gel, a peroxide source, a peroxide activator, and a compound containing a mixture of KHSO.sub.5, KHSO.sub.4 and K.sub.2 SO.sub.4. The formulation is self-decontaminating and once dried can easily be wiped from the surface being decontaminated. A method for decontaminating a surface exposed to chemical or biological agents is also disclosed.

  8. Decontamination of Soil Contaminated with Bacillus anthracis ...

    Science.gov (United States)

    Technical Brief This technical summary will provide decontamination personnel rapid access to information on which decontamination approaches are most effective for soils contaminated with B anthracis.

  9. Mass Casualty Decontamination in a Chemical or Radiological/ Nuclear Incident: Further Guiding Principles

    Science.gov (United States)

    Carter, Holly; Amlôt, Richard; Williams, Richard; Rubin, G. James; Drury, John

    2016-01-01

    This short report presents a response to an article written by Cibulsky et al. (2016). The paper by Cibulsky et al. presents a useful and timely overview of the evidence surrounding the technical and operational aspects of mass casualty decontamination. It identifies three priority targets for future research, the third of which is how casualties' needs can be met in ways that best support compliance with and effectiveness of casualty decontamination. While further investigation into behavioural, communication and privacy issues during mass decontamination is warranted, there is now a substantial body of research in this area which is not considered in detail in the succinct summary provided by Cibulsky et al. (2016). In this short report, we summarise the available evidence around likely public behaviour during mass decontamination, effective communication strategies, and potential issues resulting from a lack of privacy. Our intention is to help further focus the research needs in this area and highlight topics on which more research is needed. PMID:27790381

  10. Irradiation as an alternative environment friendly method for microbiological decontamination of herbal raw material

    International Nuclear Information System (INIS)

    Gorecki, P.; Kedzia, B.; Migdal, W.; Owczarczyk, H.B.

    1998-01-01

    Microbiological contamination of herbal raw materials is a serious problem in the production of therapeutical preparations. A good quality of the product, according to the pharmaceutical requirements may be achieved by applying suitable methods of decontamination. The decontamination treatments should be fast and effective against all microorganisms. It should ensure the decontamination of both packaging and the product in order to act effectively against all the microorganisms present and must not reduce the sensory and technological qualities of the commodities. In the paper, the results of comparative investigations on the microbiological decontamination of herbal raw materials by chemical (ethylene oxide, methyl bromide) and physical method (irradiation) are presented. Decontamination of herbal raw materials by irradiation is a method by choice. It is because chemical methods have been recognized recently as not safe to the consumer. Irradiation, in turn, is technically feasible, very effective and friendly enough to environment process

  11. Full system decontamination. AREVAs experience in decontamination prior to decommissioning

    International Nuclear Information System (INIS)

    Topf, Christian

    2010-01-01

    Minimizing collective radiation exposure and producing free-release material are two of the highest priorities in the decommissioning of a Nuclear Power Plant (NPP). Full System Decontamination (FSD) is the most effective measure to reduce source term and remove oxide layer contamination within the plant systems. FSD is typically a decontamination of the primary coolant circuit and the auxiliary systems. In recent years AREVA NP has performed several FSDs in PWRs and BWRs prior to decommissioning by applying the proprietary CORD copyright family and AMDA copyright technology. Chemical Oxidation Reduction Decontamination or CORD represents the chemical decontamination process while AMDA stands for Automated Mobile Decontamination Appliance, AREVA NPs decontamination equipment. Described herein are the excellent results achieved for the FSDs applied at the German PWRs Stade in 2004 and Obrigheim in 2007 and for the FSDs performed at the Swedish BWRs, Barsebaeck Unit 1 in 2007 and Barsebaeck Unit 2 in 2008. All four FSDs were performed using the AREVA NP CORD family decontamination technology in combination with the AREVA NP decontamination equipment, AMDA. (orig.)

  12. Analysis on the Current Status of Chemical Decontamination Technology of Steam Generators in the Oversea Nuclear Power Plants (NPPs)

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Taebin; Kim, Sukhoon; Kim, Juyoul; Kim, Juyub; Lee, Seunghee [FNC Technology Co. Ltd., Yongin (Korea, Republic of)

    2015-10-15

    The steam generators in Hanbit Unit 3 and 4 are scheduled to be replaced in 2018 and 2019, respectively. Nevertheless, the wastes from the dismantled steam generators are currently just on-site stored in the NPP because there are no disposal measures for the waste and lack of the decontamination techniques for large-sized metallic equipment. In contrast, in the oversea NPPs, there are many practical cases of chemical decontamination not only for oversized components in the NPPs such as reactor pressure vessel and steam generator, but also for major pipes. Chemical decontamination technique is more effective in decontaminating the components with complicated shape compared with mechanical one. Moreover, a high decontamination factor can be obtained by using strong solvent, and thereby most of radionuclides can be removed. Due to these advantages, the chemical decontamination has been used most frequently for operation of decontaminating the large-sized equipment. In this study, an analysis on the current status of chemical decontamination technique used for the steam generators of the foreign commercial NPPs was performed. In this study, the three major chemical decontamination processes were reviewed, which are applied to the decommissioning process of the steam generators in the commercial NPPs of the United States, Germany, and Belgium. The three processes have the different features in aspect of solvent, while those are based in common on the oxidation and reduction between the target metal surface and solvents. In addition, they have the same goals for improving the decontamination efficiency and decreasing the amount of the secondary waste generation. Based on the analysis results on component sub-processes and major advantages and disadvantages of each process, Table 2 shows the key fundamental technologies for decontamination of the steam generator in Korea and the major considerations in the development process of each technology. It is necessary to prepare

  13. Modeling the transport of chemical warfare agents and simulants in polymeric substrates for reactive decontamination

    Science.gov (United States)

    Pearl, Thomas; Mantooth, Brent; Varady, Mark; Willis, Matthew

    2014-03-01

    Chemical warfare agent simulants are often used for environmental testing in place of highly toxic agents. This work sets the foundation for modeling decontamination of absorbing polymeric materials with the focus on determining relationships between agents and simulants. The correlations of agents to simulants must consider the three way interactions in the chemical-material-decontaminant system where transport and reaction occur in polymer materials. To this end, diffusion modeling of the subsurface transport of simulants and live chemical warfare agents was conducted for various polymer systems (e.g., paint coatings) with and without reaction pathways with applied decontamination. The models utilized 1D and 2D finite difference diffusion and reaction models to simulate absorption and reaction in the polymers, and subsequent flux of the chemicals out of the polymers. Experimental data including vapor flux measurements and dynamic contact angle measurements were used to determine model input parameters. Through modeling, an understanding of the relationship of simulant to live chemical warfare agent was established, focusing on vapor emission of agents and simulants from materials.

  14. Decontaminated salt disposal as saltcrete in a landfill. Technical data summary

    International Nuclear Information System (INIS)

    1982-01-01

    This technical data summary presents a reference process for immobilizing decontaminated salt solution from the 200-Area waste storage tanks with cement, and disposing of the final waste material (called saltcrete) by burial in trenches. The saltcrete will be protected from leaching by clay and will be placed at least 3 meters above the historic high water table and beneath at least 5 meters of soil overburden. The decontaminated salt solution is a waste material which remains after the bulk of the radionuclides have been removed from waste tank supernate. This removal is effected by contacting the waste supernate with sodium tetraphenyl boron (Na-TPB) and sodium titanate (NaTi 2 O 5 H). These materials remove (by precipitation) most of the 137 Cs and 90 Sr as well as many other radioactive and non-radioactive elements. These precipitates, along with many other sludges which reside in the HLW tanks will be incorporated in borosilicate glass for eventual disposal in a geologic repository. An ion exchange process will also be used for removal of 99 Tc. The decontaminated salt solution has sufficiently low levels of radioactivity that it can be disposed of on-site. The scope of the curent effort is to describe a process for blending decontaminated salt solution with cement to form a saltcrete product which has dimensional stability and relatively low leachability. The process is to be capable of solidifying 10 gpm of supernate. About 100 million gallons of salt solution is to be solidified

  15. Toshiba's decontamination technologies for the decommissioning

    International Nuclear Information System (INIS)

    Inoue, Yuki; Yaita, Yumi; Sakai, Hitoshi

    2011-01-01

    For the decommissioning, two types of decontamination process are necessary, 1) system decontamination before dismantling and 2) decontamination of dismantling waste. Toshiba has been developing the decontamination technologies for the both purposes from the viewpoint of minimizing the secondary waste. For the system decontamination before dismantling, chemical decontamination process, such as T-OZON, can be applicable for stainless steel or carbon steel piping. For the decontamination of dismantling waste, several types of process have been developed to apply variety of shapes and materials. For the simple shape materials, physical decontamination process, such as blast decontamination, is effective. We have developed new blast decontamination process with highly durable zirconia particle. It can be used repeatedly and secondary waste can be reduced compared with conventional blast particle. For the complex shape materials, chemical decontamination process can be applied that formic acid decontamination process for carbon steel and electrolytic reduction decontamination process with organic acid for stainless steel. These chemicals can be decomposed to carbon dioxide and water and amount of secondary waste can be small. (author)

  16. Processes of elimination of activated corrosion products. Chemical decontamination - fuel cleaning

    International Nuclear Information System (INIS)

    Viala, C.; Brun, C.; Neuhaus, R.; Richier, S.; Bachet, M.

    2007-01-01

    The abatement of the individual and collective dose of a PWR imposes to control the source term through different processes implemented during the plant exploitation. When the limits of these different optimization processes are reached, the abatement of dose rates requires the implementation of curative processes. The objective is thus to eliminate the contaminated oxides and deposits present on surfaces free of radiation flux, and eventually on surfaces under radiation flux and on the fuel itself. The chemical decontamination of equipments and systems is the main and universal remedy implemented at different levels. On the other hand, the ultrasonic cleaning of fuel assemblies is a promising process. This paper aims at illustrating these different techniques using concrete examples of application in France and abroad (decontamination during steam generator replacement, decontamination of primary pump scroll in hot workshop, decontamination of loop sections, ultrasonic cleaning of fuel). The description of these different operations stresses on their efficiency in terms of dosimetric gain, duration of implementation, generation of wastes, and recontamination following their implementation. (J.S.)

  17. Evaluation on Safety of Stainless Steels in Chemical Decontamination Process with Immersion Type of Reactor Coolant Pump for Nuclear Reactor

    International Nuclear Information System (INIS)

    Kim, Seong Jong; Han, Min Su; Jang, Seok Ki; Kim, Ki Joon

    2011-01-01

    Due to commercialization of nuclear power, most countries have taken interest in decontamination process of nuclear power plant and tried to develop a optimum process. Because open literature of the decontamination process are rare, it is hard to obtain skills on decontamination of foreign country and it is necessarily to develop proper chemical decontamination process system in Korea. In this study, applicable possibility in chemical decontamination for reactor coolant pump (RCP) was investigated for the various stainless steels. The stainless steel (STS) 304 showed the best electrochemical properties for corrosion resistance and the lowest weight loss ratio in chemical decontamination process with immersion type than other materials. However, the pitting corrosion was generated in both STS 415 and STS 431 with the increasing numbers of cycle. The intergranular corrosion in STS 431 was sporadically observed. The sizes of their pitting corrosion also increased with increasing cycle numbers

  18. A study of the decontamination procedures used for chemical analysis of polar deep ice cores

    Directory of Open Access Journals (Sweden)

    Takayuki Miyake

    2009-11-01

    Full Text Available We investigated the decontamination procedures used on polar deep ice cores before chemical analyses such as measurements of the concentrations of iron species and dust (microparticles. We optimized cutting and melting protocols for decontamination using chemically ultraclean polyethylene bags and simulated ice samples made from ultrapure water. For dust and ion species including acetate, which represented a high level of contamination, we were able to decrease contamination to below several μg l^ for ion concentrations and below 10000 particles ml^ for the dust concentration. These concentration levels of ion species and dust are assumed to be present in the Dome Fuji ice core during interglacial periods. Decontamination of the ice core was achieved by cutting away approximately 3 mm of the outside of a sample and by melting away approximately 30% of a sample's weight. Furthermore, we also report the preparation protocols for chemical analyses of the 2nd Dome Fuji ice core, including measurements of ion and dust concentrations, pH, electric conductivity (EC, and stable isotope ratios of water (δD and δO, based on the results of the investigation of the decontamination procedures.

  19. Role of alkyl alcohol on viscosity of silica-based chemical gels for decontamination of highly radioactive nuclear facilities

    International Nuclear Information System (INIS)

    Choi, B. S.; Yoon, S. B.; Jung, C. H.; Lee, K. W.; Moon, J. K.

    2012-01-01

    Silica-based chemical gel for the decontamination of nuclear facilities was prepared by using fumed silica as a viscosifier, a 0.5 M Ce (IV) solution dissolved in concentrated nitric acid as a chemical decontamination agent, and tripropylene glycol butyl ether (TPGBE) as a co-viscosifier. A new effective strategy for the preparation of the chemical gel was investigated by introducing the alkyl alcohols as organic solvents to effectively dissolve the co-viscosifier. The mixture solution of the co-viscosifier and alkyl alcohols was more effective in the control of viscosity than that of the co-viscosifier only in gel. Here, the alkyl alcohols played a key role as an effective dissolution solvent for the co-viscosifier in the preparation of the chemical gel, resulting in a reducing of the amount of the co-viscosifier and gel time compared with that of the chemical gel prepared without the alkyl alcohols. It was considered that the alkyl alcohols contributed to the effective dissolution of the co-viscosifier as well as the homogeneous mixing in the formation of the gel, while the co-viscosifier in an aqueous media of the chemical decontamination agent solution showed a lower solubility. The decontamination efficiency of the chemical gels prepared in this work using a multi-channel analyzer (MCA) showed a high decontamination efficiency of over ca. 94% and ca. 92% for Co-60 and Cs-137 contaminated on surface of the stainless steel 304, respectively. (authors)

  20. Development of the chemical decontamination process of uranium enrichment gas centrifuges

    International Nuclear Information System (INIS)

    Mita, Yutaka; Endo, Yuji; Yamanaka, Toshihiro; Oohashi, Yusuke

    2002-01-01

    In Ningyo-Toge Environmental Engineering Center, many of the centrifuges that were tested for uranium enrichment are kept in storage. In the future, it will be necessary to dispose of them properly. By categorizing these centrifuges as 'items that are not required to be treated as radioactive waste', chemical decontamination tests were conducted with the wet process (diluted sulfuric acid) to reduce the amount of such radioactive waste. As a result, concerning the rotors, the assumed radioactive level was attained as items that are not required to be treated as radioactive waste', but the effectiveness of the casings varied. As a future subject, in order to find the optimal decontamination process, the basic test shall be conducted continuously. By taking economical efficiency and the processing time into consideration, the decontamination process will be evaluated and a rational method examined. (author)

  1. Properties and solidification of decontamination wastes

    International Nuclear Information System (INIS)

    Davis, M.S.; Piciulo, P.L.; Bowerman, B.S.; Adams, J.W.; Milian, L.

    1983-01-01

    LWRs will require one or more chemical decontaminations to achieve their designed lifetimes. Primary system decontamination is designed to lower radiation fields in areas where plant maintenance personnel must work. Chemical decontamination methods are either hard (concentrated chemicals, approximately 5 to 25 weight percent) or soft (dilute chemicals less than 1 percent by weight). These methods may have different chemical reagents, some tailor-made to the crud composition and many methods are and will be proprietary. One factor common to most commercially available processes is the presence of organic acids and chelates. These types of organic reagents are known to enhance the migration of radionuclides after disposal in a shallow land burial site. The NRC sponsors two programs at Brookhaven National Laboratory that are concerned with the management of decontamination wastes which will be generated by the full system decontamination of LWRs. These two programs focus on potential methods for degrading or converting decontamination wastes to more acceptable forms prior to disposal and the impact of disposing of solidified decontamination wastes. The results of the solidification of simulated decontamination resin wastes will be presented. Recent results on combustion of simulated decontamintion wastes will be described and procedures for evaluating the release of decontamination reagents from solidified wastes will be summarized

  2. Method for decontaminating radiation metal waste

    International Nuclear Information System (INIS)

    Onuma, Tsutomu; Tanaka, Akio; Akimoto, Hidetoshi

    1991-01-01

    This report describes a method for decontaminating radiation metal waste characterized by the following properties: in order to decontaminate radiation metal waste of various shapes produced by facilities involved with radioactive substances, non-complex shapes are decontaminated by electropolishing the materials in a neutral saline solution. Complex shapes are chemically decontaminated by means of an acid solution containing permanganic acid or an alkaline solution and a mineral acid solution. After neutralizing the solutions used for chemical decontamination, the radioactive material is separated and removed. Further, in the decontamination method for radioactive metal waste, a supernatant liquid is reused as the electrolyte in electropolishing decontamination. Permanganic ions (MnO 4 - ) are reduced to manganese dioxide (MnO 2 ) and deposited prior to neutralizing the solution used for chemical decontamination. Once manganese dioxide (MnO 2 ) has been separated and removed, it is re-used as the electrolyte in electropolishing decontamination by means of a process identical to the separation process for radioactive substances. 3 figs

  3. PWR decontamination feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Silliman, P.L.

    1978-12-18

    The decontamination work which has been accomplished is reviewed and it is concluded that it is worthwhile to investigate further four methods for decontamination for future demonstration. These are: dilute chemical; single stage strong chemical; redox processes; and redox/chemical in combination. Laboratory work is recommended to define the agents and processes for demonstration and to determine the effect of the solvents on PWR materials. The feasibility of Indian Point 1 for decontamination demonstrations is discussed, and it is shown that the system components of Indian Point 1 are well suited for use in demonstrations.

  4. PWR decontamination feasibility study

    International Nuclear Information System (INIS)

    Silliman, P.L.

    1978-01-01

    The decontamination work which has been accomplished is reviewed and it is concluded that it is worthwhile to investigate further four methods for decontamination for future demonstration. These are: dilute chemical; single stage strong chemical; redox processes; and redox/chemical in combination. Laboratory work is recommended to define the agents and processes for demonstration and to determine the effect of the solvents on PWR materials. The feasibility of Indian Point 1 for decontamination demonstrations is discussed, and it is shown that the system components of Indian Point 1 are well suited for use in demonstrations

  5. Decontamination of paint-coated concrete in nuclear plants using laser technology

    Energy Technology Data Exchange (ETDEWEB)

    Anthofer, Anton; Lippmann, Wolfgang; Hurtado, Antonio [Technische Univ. Dresden (Germany). Chair of Hydrogen and Nuclear Technology

    2013-07-01

    A review of the state of the art shows the technical novelty of the combined project. The development of an all-in-one process for treatment hazard chemical contamination on concrete structures with online monitoring method reduces the laborious mechanic decontamination and post-treatment. For safe experimental investigations, a three-barrier-system was constructed and can be used for tests with - first - epoxy paint in order to analyze and optimize the process. Simulation models help to formulate a mathematic scheme of the decontamination process by laser technology. The goal is a decontamination system with an online analyzing system of the flue gas for a mobile and extensive component in nuclear and conventional decommission. (orig.)

  6. Air Activated Self-Decontaminating Polydicyclopentadiene PolyHIPE Foams for Rapid Decontamination of Chemical Warfare Agents.

    Science.gov (United States)

    McGann, Christopher L; Daniels, Grant C; Giles, Spencer L; Balow, Robert B; Miranda-Zayas, Jorge L; Lundin, Jeffrey G; Wynne, James H

    2018-06-01

    The threat of chemical warfare agents (CWA) compels research into novel self-decontaminating materials (SDM) for the continued safety of first-responders, civilians, and active service personnel. The capacity to actively detoxify, as opposed to merely sequester, offending agents under typical environmental conditions defines the added value of SDMs in comparison to traditional adsorptive materials. Porous polymers, synthesized via the high internal phase emulsion (HIPE) templating, provide a facile fabrication method for materials with permeable open cellular structures that may serve in air filtration applications. PolyHIPEs comprising polydicyclopentadiene (polyDCPD) networks form stable hydroperoxide species following activation in air under ambient conditions. The hydroperoxide-containing polyDCPD materials react quickly with CWA simulants, Demeton-S and 2-chloroethyl ethyl sulfide, forming oxidation products as confirmed via gas chromatography mass spectrometry. The simplicity of the detoxification chemistry paired with the porous foam form factor presents an exciting opportunity for the development of self-decontaminating filter media. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Restoration projects for decontamination of facilities from chemical, biological and radiological contamination after terrorist actions

    Energy Technology Data Exchange (ETDEWEB)

    Fingas, M.; Volchek, K.; Lumley, T.; Thouin, G.; Harrison, S.; Kuang, W. [Environment Canada, Ottawa, ON (Canada). Emergencies Science and Technology Division, Environmental Technology Centre, Science and Technology Branch; Payette, P.; Laframboise, D.; Best, M. [Public Health Agency of Canada, Ottawa, ON (Canada); Krishnan, J.; Wagener, S.; Bernard, K.; Majcher, M. [Public Health Agency of Canada, Winnipeg, MB (Canada); Cousins, T.; Jones, T. [Defence Research and Development Canada, Ottawa, ON (Canada); Velicogna, D.; Hornof, M.; Punt, M. [SAIC Canada, Ottawa, ON (Canada)

    2006-07-01

    This paper reviewed studies that identified better decontamination methods for chemical, biological and radiological/nuclear (CBRN) attacks. In particular, it reviewed aspects of 3 projects in which procedures were tested and validated for site restoration. Cleanup targets or standards for decontaminating buildings and materials after a CBRN attack were also developed. The projects were based on physicochemical and toxicological knowledge of potential terrorist agents and selected surface matrices. The projects also involved modeling and assessing environmental and health risks. The first multi-agent project involved gathering information on known procedures for restoration of areas including interiors and exteriors of buildings, contents, parking lots, lawn, and vehicles. Air inside the building was included. The efficacy of some of the proposed concepts was tested. Results included the determination of appropriate surrogates for anthrax and tests of liquid and gaseous biocides on the surrogates. The development of new contamination procedures using peroxyacetic acid were also discussed. The second project involved decontamination tests on CBRN using specially-constructed buildings at the Counter-terrorism Technology Centre at Defence Research and Development Canada in Suffield. The buildings will be contaminated with chemical and biological agents and with short-lived radionuclides. They will be decontaminated using the best-performing technologies known. Information collected will include fate of the contaminant and decontamination products, effectiveness of the restoration methods, cost and duration of cleanup and logistical problems. The third project is aimed at developing cleanup standards for decontaminating buildings and construction materials after a chemical or biological attack. It will create as many as 12 algorithms for the development of 50 standards which will help cleanup personnel and first-responders to gauge whether proposed methods can achieve

  8. Chemical Decontamination of Metallic Waste from Uranium Conversion Plant Dismantling

    International Nuclear Information System (INIS)

    Hwang, D. S.; Choi, Y. D.; Hwang, S. T.; Park, J. H.; Byun, J. I.; Jang, N. S.

    2005-01-01

    Korea Atomic Energy Research Institute (KAERI) started a decommissioning program of the uranium conversion plant. Pre-work was carried as follows; installation of the access control facility, installation of a changing room and shower room, designation of an emergency exit way and indicating signs, installation of a radiation management facility, preparation of a storage area for tools and equipments, inspection and load test of crane, distribution and packaging of existing waste, and pre-decontamination of the equipment surface and the interior. First, decommissioning work was performed in kiln room, which will be used for temporary radioactive waste storage room. Kiln room housed hydro fluorination rotary kiln for production of uranium tetra-fluoride. The kiln is about 0.8 m in diameter and 5.5 m long. The total dismantled waste was 6,690 kg, 73 % of which was metallic waste and 27 % the others such as cable, asbestos, concrete, secondary waste, etc. And effluent treatment room and filtration room were dismantled for installation of decontamination equipment and lagoon sludge treatment equipment. There were tanks and square mixer in these rooms. The total dismantled waste was 17,250 kg, 67% of which was metallic waste and 33% the others. These dismantled metallic wastes consist of stainless and carbon steel. In this paper, the stainless steel plate and pipe were decontaminated by the chemical decontamination with ultrasonic

  9. Development of Bicarbonate-Activated Peroxide as a Chemical and Biological Warfare Agent Decontaminant

    National Research Council Canada - National Science Library

    Richardson, David E

    2006-01-01

    ...) and other chemistry for the decontamination of chemical and biological warfare agents. The mechanism of formation of the active oxidant, peroxymonocarbonate, has been investigated in detail. New surfoxidants...

  10. Decontamination issues for chemical and biological warfare agents: how clean is clean enough?

    Science.gov (United States)

    Raber, E; Jin, A; Noonan, K; McGuire, R; Kirvel, R D

    2001-06-01

    The objective of this assessment is to determine what level of cleanup will be required to meet regulatory and stakeholder needs in the case of a chemical and/or biological incident at a civilian facility. A literature review for selected, potential chemical and biological warfare agents shows that dose information is often lacking or controversial. Environmental regulatory limits or other industrial health guidelines that could be used to help establish cleanup concentration levels for such agents are generally unavailable or not applicable for a public setting. Although dose information, cleanup criteria, and decontamination protocols all present challenges to effective planning, several decontamination approaches are available. Such approaches should be combined with risk-informed decision making to establish reasonable cleanup goals for protecting health, property, and resources. Key issues during a risk assessment are to determine exactly what constitutes a safety hazard and whether decontamination is necessary or not for a particular scenario. An important conclusion is that cleanup criteria are site dependent and stakeholder specific. The results of a modeling exercise for two outdoor scenarios are presented to reinforce this conclusion. Public perception of risk to health, public acceptance of recommendations based on scientific criteria, political support, time constraints, and economic concerns must all be addressed in the context of a specific scenario to yield effective and acceptable decontamination.

  11. The restoration project : decontamination of facilities from chemical, biological and radiological contamination after terrorist action

    Energy Technology Data Exchange (ETDEWEB)

    Fingas, M.; Volchek, K.; Thouin, G.; Harrison, S.; Kuang, W. [Environment Canada, Ottawa, ON (Canada). Emergencies Science Div; Velicogna, D.; Hornof, M.; Punt, M. [SAIC Canada, Ottawa, ON (Canada); Payette, P.; Duncan, L.; Best, M.; Krishnan; Wagener, S.; Bernard, K.; Majcher, M. [Public Health Agency of Canada, Ottawa, ON (Canada); Cousins, T.; Jones, T. [Defence Research and Development Canada, Ottawa, ON (Canada)

    2005-07-01

    Bioterrorism poses a real threat to the public health and national security, and the restoration of affected facilities after a chemical, biological or radiological attack is a major concern. This paper reviewed aspects of a project conducted to collect information, test and validate procedures for site restoration after a terrorist attack. The project began with a review of existing technology and then examined new technologies. Restoration included pickup, neutralization, decontamination, removal and final destruction and deposition of contaminants as well as cleaning and neutralization of material and contaminated waste from decontamination. The project was also intended to test existing concepts and develop new ideas. Laboratory scale experiments consisted of testing, using standard laboratory techniques. Radiation decontamination consisted of removal and concentration of the radioisotopes from removal fluid. General restoration guidelines were provided, as well as details of factors considered important in specific applications, including growth conditions and phases of microorganisms in biological decontamination, or the presence of inhibitors or scavengers in chemical decontamination. Various agents were proposed that were considered to have broad spectrum capability. Test surrogates for anthrax were discussed. The feasibility of enhanced oxidation processes was examined in relation to the destruction of organophosphorus, organochlorine and carbamate pesticides. The goal was to identify a process for the treatment of surfaces contaminated with pesticides. Tests included removal from carpet, porous ceiling tile, steel plates, and floor tiles. General radiation contamination procedures and techniques were reviewed, as well as radiological decontamination waste treatment. It was concluded that there is no single decontamination technique applicable for all contaminants, and decontamination methods depend on economic, social and health factors. The amount of

  12. Chemical decontamination method for stainless steel

    International Nuclear Information System (INIS)

    Yomo, Nobuo; Onuma, Tsutomu; Akimoto, Hidetoshi.

    1991-01-01

    In a case where an object to be decontaminated has a restricted portion in which the passage of liquids is difficult, decontamination liquids are not circulated effectively upon decontamination for the inner surfaces, and it requires a quite long period of time. In view of the above, through holes are perforated by, for example, a drill in the restricted portion of metal wastes made of stainless steels. Then, they are immersed in a sulfuric acid solution, and further immersed in an aqueous solution in which oxidative metal salts are added to the sulfuric acid. With such procedures, substrates are exposed at the inner circumference of the holes even if they are fine holes, and a local cell is formed between the substrate and an oxidized membranes, which may cause dissolution due to the reduction of the oxidized membranes. Further, since it is possible to discharge bubbles formed upon the solution, even from such fine holes, decontamination can be conducted effectively. (T.M.)

  13. Effective Responder Communication Improves Efficiency and Psychological Outcomes in a Mass Decontamination Field Experiment: Implications for Public Behaviour in the Event of a Chemical Incident

    Science.gov (United States)

    Carter, Holly; Drury, John; Amlôt, Richard; Rubin, G. James; Williams, Richard

    2014-01-01

    The risk of incidents involving mass decontamination in response to a chemical, biological, radiological, or nuclear release has increased in recent years, due to technological advances, and the willingness of terrorists to use unconventional weapons. Planning for such incidents has focused on the technical issues involved, rather than on psychosocial concerns. This paper presents a novel experimental study, examining the effect of three different responder communication strategies on public experiences and behaviour during a mass decontamination field experiment. Specifically, the research examined the impact of social identity processes on the relationship between effective responder communication, and relevant outcome variables (e.g. public compliance, public anxiety, and co-operative public behaviour). All participants (n = 111) were asked to visualise that they had been involved in an incident involving mass decontamination, before undergoing the decontamination process, and receiving one of three different communication strategies: 1) ‘Theory-based communication’: Health-focused explanations about decontamination, and sufficient practical information; 2) ‘Standard practice communication’: No health-focused explanations about decontamination, sufficient practical information; 3) ‘Brief communication’: No health-focused explanations about decontamination, insufficient practical information. Four types of data were collected: timings of the decontamination process; observational data; and quantitative and qualitative self-report data. The communication strategy which resulted in the most efficient progression of participants through the decontamination process, as well as the fewest observations of non-compliance and confusion, was that which included both health-focused explanations about decontamination and sufficient practical information. Further, this strategy resulted in increased perceptions of responder legitimacy and increased

  14. Effective responder communication improves efficiency and psychological outcomes in a mass decontamination field experiment: implications for public behaviour in the event of a chemical incident.

    Science.gov (United States)

    Carter, Holly; Drury, John; Amlôt, Richard; Rubin, G James; Williams, Richard

    2014-01-01

    The risk of incidents involving mass decontamination in response to a chemical, biological, radiological, or nuclear release has increased in recent years, due to technological advances, and the willingness of terrorists to use unconventional weapons. Planning for such incidents has focused on the technical issues involved, rather than on psychosocial concerns. This paper presents a novel experimental study, examining the effect of three different responder communication strategies on public experiences and behaviour during a mass decontamination field experiment. Specifically, the research examined the impact of social identity processes on the relationship between effective responder communication, and relevant outcome variables (e.g. public compliance, public anxiety, and co-operative public behaviour). All participants (n = 111) were asked to visualise that they had been involved in an incident involving mass decontamination, before undergoing the decontamination process, and receiving one of three different communication strategies: 1) 'Theory-based communication': Health-focused explanations about decontamination, and sufficient practical information; 2) 'Standard practice communication': No health-focused explanations about decontamination, sufficient practical information; 3) 'Brief communication': No health-focused explanations about decontamination, insufficient practical information. Four types of data were collected: timings of the decontamination process; observational data; and quantitative and qualitative self-report data. The communication strategy which resulted in the most efficient progression of participants through the decontamination process, as well as the fewest observations of non-compliance and confusion, was that which included both health-focused explanations about decontamination and sufficient practical information. Further, this strategy resulted in increased perceptions of responder legitimacy and increased identification with

  15. Effective responder communication improves efficiency and psychological outcomes in a mass decontamination field experiment: implications for public behaviour in the event of a chemical incident.

    Directory of Open Access Journals (Sweden)

    Holly Carter

    Full Text Available The risk of incidents involving mass decontamination in response to a chemical, biological, radiological, or nuclear release has increased in recent years, due to technological advances, and the willingness of terrorists to use unconventional weapons. Planning for such incidents has focused on the technical issues involved, rather than on psychosocial concerns. This paper presents a novel experimental study, examining the effect of three different responder communication strategies on public experiences and behaviour during a mass decontamination field experiment. Specifically, the research examined the impact of social identity processes on the relationship between effective responder communication, and relevant outcome variables (e.g. public compliance, public anxiety, and co-operative public behaviour. All participants (n = 111 were asked to visualise that they had been involved in an incident involving mass decontamination, before undergoing the decontamination process, and receiving one of three different communication strategies: 1 'Theory-based communication': Health-focused explanations about decontamination, and sufficient practical information; 2 'Standard practice communication': No health-focused explanations about decontamination, sufficient practical information; 3 'Brief communication': No health-focused explanations about decontamination, insufficient practical information. Four types of data were collected: timings of the decontamination process; observational data; and quantitative and qualitative self-report data. The communication strategy which resulted in the most efficient progression of participants through the decontamination process, as well as the fewest observations of non-compliance and confusion, was that which included both health-focused explanations about decontamination and sufficient practical information. Further, this strategy resulted in increased perceptions of responder legitimacy and increased

  16. Decontamination device for pipeline

    International Nuclear Information System (INIS)

    Harashina, Heihachi.

    1994-01-01

    Pipelines to be decontaminated are parts of pipelines contaminated with radioactive materials, and they are connected to a fluid transfer means (for example, a bladeless pump) and a ball collector by way of a connector. The fluid of a mixture of chemical decontaminating liquid and spheres is sent into pipelines to be decontaminated. The spheres are, for example, heat resistant porous hard or soft rubber spheres. The fluid discharged from the pipelines to be decontaminated are circulated by way of bypassing means. The inner surface of the pipelines is decontaminated by the circulation of the fluid. When the bypass means is closed, the fluid discharged from the pipelines to be decontaminated is sent to the ball collector, and the spheres are captured by a hopper. Further, the liquid is sent to the filtrating means to filter the chemical contaminating liquid, and sludges contained in the liquid are captured. (I.N.)

  17. Fate of the chemical warfare agent O-ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX) on soil following accelerant-based fire and liquid decontamination.

    Science.gov (United States)

    Gravett, M R; Hopkins, F B; Self, A J; Webb, A J; Timperley, C M; Riches, J R

    2014-08-01

    In the event of alleged use of organophosphorus nerve agents, all kinds of environmental samples can be received for analysis. These might include decontaminated and charred matter collected from the site of a suspected chemical attack. In other scenarios, such matter might be sampled to confirm the site of a chemical weapon test or clandestine laboratory decontaminated and burned to prevent discovery. To provide an analytical capability for these contingencies, we present a preliminary investigation of the effect of accelerant-based fire and liquid decontamination on soil contaminated with the nerve agent O-ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX). The objectives were (a) to determine if VX or its degradation products were detectable in soil after an accelerant-based fire promoted by aviation fuel, including following decontamination with Decontamination Solution 2 (DS2) or aqueous sodium hypochlorite, (b) to develop analytical methods to support forensic analysis of accelerant-soaked, decontaminated and charred soil and (c) to inform the design of future experiments of this type to improve analytical fidelity. Our results show for the first time that modern analytical techniques can be used to identify residual VX and its degradation products in contaminated soil after an accelerant-based fire and after chemical decontamination and then fire. Comparison of the gas chromatography-mass spectrometry (GC-MS) profiles of VX and its impurities/degradation products from contaminated burnt soil, and burnt soil spiked with VX, indicated that the fire resulted in the production of diethyl methylphosphonate and O,S-diethyl methylphosphonothiolate (by an unknown mechanism). Other products identified were indicative of chemical decontamination, and some of these provided evidence of the decontaminant used, for example, ethyl 2-methoxyethyl methylphosphonate and bis(2-methoxyethyl) methylphosphonate following decontamination with DS2. Sample preparation

  18. Autonomous bio-chemical decontaminator (ABCD) against weapons of mass destruction

    Science.gov (United States)

    Hyacinthe, Berg P.

    2006-05-01

    The proliferation of weapons of mass destruction (WMD) and the use of such elements pose an eminent asymmetric threat with disastrous consequences to the national security of any nation. In particular, the use of biochemical warfare agents against civilians and unprotected troops in international conflicts or by terrorists against civilians is considered as a very peculiar threat. Accordingly, taking a quarantine-before-inhalation approach to biochemical warfare, the author introduces the notion of autonomous biochemical decontamination against WMD. In the unfortunate event of a biochemical attack, the apparatus proposed herein is intended to automatically detect, identify, and more importantly neutralize a biochemical threat. Along with warnings concerning a cyber-WMD nexus, various sections cover discussions on human senses and computer sensors, corroborating evidence related to detection and neutralization of chemical toxins, and cyber-assisted olfaction in stand alone, peer-to-peer, and network settings. In essence, the apparatus can be used in aviation and mass transit security to initiate mass decontamination by dispersing a decontaminant aerosol or to protect the public water supply against a potential bioterrorist attack. Future effort may involve a system-on-chip (SoC) embodiment of this apparatus that allows a safer environment for the emerging phenomenon of cyber-assisted olfaction and morph cell phones into ubiquitous sensors/decontaminators. Although this paper covers mechanisms and protocols to avail a neutralizing substance, further research will need to explore the substance's various pharmacological profiles and potential side effects.

  19. Decontamination processes for waste glass canisters

    International Nuclear Information System (INIS)

    Rankin, W.N.

    1981-06-01

    The process which will be used to decontaminate waste glass canisters at the Savannah River Plant consists of: decontamination (slurry blasting); rinse (high-pressure water); and spot decontamination (high-pressure water plus slurry). No additional waste will be produced by this process because glass frit used in decontamination will be mixed with the radioactive waste and fed into the glass melter. Decontamination of waste glass canisters with chemical and abrasive blasting techniques was investigated. The ability of a chemical technique with HNO 3 -HF and H 2 C 2 O 4 to remove baked-on contamination was demonstrated. A correlation between oxide removal and decontamination was observed. Oxide removal and, thus, decontamination by abrasive blasting techniques with glass frit as the abrasive was proposed and demonstrated

  20. Decontamination processes for waste glass canisters

    International Nuclear Information System (INIS)

    Rankin, W.N.

    1981-01-01

    The process which will be used to decontaminate waste glass canisters at the Savannah River Plant consists of: decontamination (slurry blasting); rinse (high-pressure water); and spot decontamination (high-pressure water plus slurry). No additional waste will be produced by this process because glass frit used in decontamination will be mixed with the radioactive waste and fed into the glass melter. Decontamination of waste glass canisters with chemical and abrasive blasting techniques was investigated. The ability of a chemical technique with HNO 3 -HF and H 2 C 2 O 4 to remove baked-on contamination was demonstrated. A correlation between oxide removal and decontamination was observed. Oxide removal and, thus, decontamination by abrasive blasting techniques with glass frit as the abrasive was proposed and demonstrated

  1. Radiation decontamination of dry food ingredients and processing aids

    Energy Technology Data Exchange (ETDEWEB)

    Farkas, J

    1984-01-01

    Radiation decontamination of dry ingredients, herbs and enzyme preparations is a technically feasible, economically viable and safe physical process. The procedure is direct, simple, requires no additives and is highly efficient. Its dose requirement is moderate. Radiation doses of 3-10 kGy (0.3-1 mrad) have proved sufficient to reduce the viable counts to a satisfactory level. Ionising radiations do not cause any significant rise in temperature. The flavour, texture or other important technological or sensory properties of most ingredients are not influenced at radiation doses necessary for satisfactory decontamination, and radiation obviates the chemical residue problem. The microflora surviving radiation decontamination of dry ingredients are more susceptible to subsequent antimicrobial treatments. Recontamination can be prevented as the product can be irradiated in its final packaging. Irradiation could be carried out in commercial containers and would result in considerable savings of energy and labour as compared to alternative decontamination techniques. Radiation processing of these commodities is an established technology in several countries and more clearances on irradiated foods are expected to be granted in the near future.

  2. The ultrasonic copper and brass decontamination study; Etude de la decontamination du cuivre et des laitons en presence d'ultra-sons

    Energy Technology Data Exchange (ETDEWEB)

    Courtault, J; Kerdelleau, J de; Mestre, E [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    The use of ultra-sounds as a decontamination technic does not bring an absolute solution. As a function of the materials it seemed necessary to find what was the optimum conditions for using the ultra-sounds and to define not only the ultra-sonic factors but also the chemical solutions which bring some appreciable decontamination factors without bringing any too important corrosion processus. This report gives the results of this study applied to copper and brass. This study allowed to select some effective treatment baths on the two types of contamination: plutonium and fission products. (authors) [French] L'emploi des ultra-sons comme technique de decontamination n'amene pas une solution absolue. Il est apparu necessaire de rechercher en fonction de la nature du materiau a decontaminer quelles etaient les conditions optimales d'utilisation des ultra-sons et de definir alors non seulement les facteurs ultrasoniques mais encore les solutions chimiques qui apportent des facteurs de decontamination appreciables sans amener des phenomenes de corrosion trop importants. Ce rapport donne les resultats de cette etude appliquee au cuivre et aux laitons. Cette etude a permis de selectionner des bains de traitement efficaces dans les deux cas de contamination: plutonium et produits de fission. (auteurs)

  3. Overview of nonchemical decontamination techniques

    International Nuclear Information System (INIS)

    Allen, R.P.

    1984-09-01

    The decontamination techniques summarized in this paper represent a variety of surface cleaning methods developed or adapted for component and facility-type decontamination applications ranging from small hand tools to reactor cavities and other large surface areas. The major conclusion is that decontamination is a complex, demanding technical discipline. It requires knowledgeable, experienced and well-trained personnel to select proper techniques and combinations of techniques for the varied plant applications and to realize their full performance potential. Unfortunately, decontamination in many plants has the lowest priority of almost any activity. Operators are unskilled and turnover is so frequent that expensive decontamination capabilities remain unused while decontamination operations revert to the most rudimentary type of hand scrubbing and water spray cleaning

  4. Optimization of Nonambulant Mass Casualty Decontamination Protocols as Part of an Initial or Specialist Operational Response to Chemical Incidents.

    Science.gov (United States)

    Chilcott, Robert P; Mitchell, Hannah; Matar, Hazem

    2018-05-30

    The UK's Initial Operational Response (IOR) is a new process for improving the survival of multiple casualties following a chemical, biological, radiological or nuclear incident. Whilst the introduction of IOR represents a patient-focused response for ambulant casualties, there is currently no provision for disrobe and dry decontamination of nonambulant casualties. Moreover, the current specialist operational response (SOR) protocol for nonambulant casualty decontamination (also referred to as "clinical decontamination") has not been subject to rigorous evaluation or development. Therefore, the aim of this study was to confirm the effectiveness of putatively optimized dry (IOR) and wet (SOR) protocols for nonambulant decontamination in human volunteers. Dry and wet decontamination protocols were objectively evaluated using human volunteers. Decontamination effectiveness was quantified by liquid chromatography-mass spectrometry analysis of the recovery of a chemical warfare agent simulant (methylsalicylate) from skin and hair of volunteers, with whole-body fluorescence imaging to quantify the skin distribution of residual simulant. Both the dry and wet decontamination processes were rapid (3 and 4 min, respectively) and were effective in removing simulant from the hair and skin of volunteers, with no observable adverse effects related to skin surface spreading of contaminant. Further studies are required to assess the combined effectiveness of dry and wet decontamination under more realistic conditions and to develop appropriate operational procedures that ensure the safety of first responders.

  5. Technical area status report for chemical/physical treatment

    International Nuclear Information System (INIS)

    Brown, C.H. Jr.; Schwinkendorf, W.E.

    1993-08-01

    The Office of Environmental Restoration and Waste Management (EM) was established by the Department of Energy (DOE) to direct and coordinate waste management and site remediation programs and activities throughout the DOE Complex. The Mixed Waste Integrated Program (MWIP) was created by the DOE Office of Technology Development (OTD) to develop, deploy, and complete appropriate technologies for the treatment of an DOE low-level mixed waste (LLMW). The MWIP mission includes development of strategies related to enhanced waste form production, improvements to and testing of the EM-30 baseline flowsheet for mixed waste treatment, programmatic oversight for ongoing technical projects, and specific technical tasks related to the site specific Federal Facilities Compliance Agreement (FFCA). The MWIP has established five Technical Support Groups (TSGs) based on primary functional areas of the Mixed Waste Treatment Plant) identified by EM-30. These TSGs are: (1) Front-End Waste Handling, (2) Chemical/Physical Treatment, (3) Waste Destruction and Stabilization, (4) Second-stage Destruction and Offgas Treatment, and (5) Final Waste Forms. The focus of this document is the Chemical/Physical Treatment System (CPTS). The CPTS performs the required pretreatment and/or separations on the waste streams passing through the system for discharge to the environment or efficient downstream processing. Downstream processing can include all system components except Front-End Waste Handling. The primary separations to be considered by the CPTS are: (1) removal of suspended and dissolved solids from aqueous and liquid organic streams, (2) separation of water from organic liquids, (3) treatment of wet and dry solids, including separation into constituents as required, for subsequent thermal treatment and final form processing, (4) mercury removal and control, and (5) decontamination of equipment and waste classified as debris

  6. Situations of decontamination promotion activities. Efforts by Tokyo Electric Power Company, Fukushima Revitalization Headquarters, Decontamination Promotion Office

    International Nuclear Information System (INIS)

    Takano, Takahiko; Ito, Kei; Takizawa, Koichi

    2015-01-01

    As for the decontamination of the soil contaminated with radioactive materials, decontamination is on the way in compliance with the 'Act on Special Measures Concerning the Handling of Environmental Pollution by Radioactive Materials by the NPS Accident Associated with the Tohoku District - Off the Pacific Ocean' (hereinafter, the Act on Special Measures). Tokyo Electric Power Company (TEPCO), as the party concerned to the accident, is cooperating with decontamination activities conducted by countries and municipalities under the Act on Special Measures. Total number of people cooperated by the Decontamination Promotion Office amounts to about 120,000 people. The cooperation to the decontamination by countries and municipalities covers the following fields: provision of knowledge of radiation, training of site management and supervisors, and proposal such as the decontamination method suitable for the site. As cooperation to various monitoring, there is a traveling monitoring that performs radiation measurement from the vehicles. As cooperation in the farming and industrial resumption toward the reconstruction, the group has implemented support for the distribution promotion of the holdup that was stuck in distribution due to contamination with radioactive substances. As decontamination related technology, the following are performed: (1) preparation of radiation understanding promotion tool, (2) development of precise individual dose measurement technology, and (3) development and utilization of decontamination effect analysis program. In the future, this group will perform the follow-up for decontamination, and measures toward the lifting of evacuation order. It will install the basis to perform various technical analyses on decontamination, and will further intensify technical cooperation. (A.O.)

  7. A decontamination system for chemical weapons agents using a liquid solution on a solid sorbent.

    Science.gov (United States)

    Waysbort, Daniel; McGarvey, David J; Creasy, William R; Morrissey, Kevin M; Hendrickson, David M; Durst, H Dupont

    2009-01-30

    A decontamination system for chemical warfare agents was developed and tested that combines a liquid decontamination reagent solution with solid sorbent particles. The components have fewer safety and environmental concerns than traditional chlorine bleach-based products or highly caustic solutions. The liquid solution, based on Decon Greentrade mark, has hydrogen peroxide and a carbonate buffer as active ingredients. The best solid sorbents were found to be a copolymer of ethylene glycol dimethacrylate and n-lauryl methacrylate (Polytrap 6603 Adsorber); or an allyl methacrylate cross-linked polymer (Poly-Pore E200 Adsorber). These solids are human and environmentally friendly and are commonly used in cosmetics. The decontaminant system was tested for reactivity with pinacolyl methylphosphonofluoridate (Soman, GD), bis(2-chloroethyl)sulfide (Mustard, HD), and S-(2-diisopropylaminoethyl) O-ethyl methylphosphonothioate (VX) by using NMR Spectroscopy. Molybdate ion (MoO(4)(-2)) was added to the decontaminant to catalyze the oxidation of HD. The molybdate ion provided a color change from pink to white when the oxidizing capacity of the system was exhausted. The decontaminant was effective for ratios of agent to decontaminant of up to 1:50 for VX (t(1/2) decontamination solution were measured to show that the sorbent decreased the vapor concentration of GD. The E200 sorbent had the additional advantage of absorbing aqueous decontamination solution without the addition of an organic co-solvent such as isopropanol, but the rate depended strongly on mixing for HD.

  8. National demonstration of full reactor coolant system (RCS) chemical decontamination at Indian Point 2

    Energy Technology Data Exchange (ETDEWEB)

    Trovato, S.A.; Parry, J.O. [Consolidated Edison Co., New York, NY (United States)

    1995-03-01

    Key to the safe and efficient operation of the nation`s civilian nuclear power plants is the performance of maintenance activities within regulations and guidelines for personnel radiation exposure. However, maintenance activities, often performed in areas of relatively high radiation fields, will increase as the nation`s plant age. With the Nuclear Regulatory Commission (NRC) lowering the allowable radiation exposure to plant workers in 1994 and considering further reductions and regulations in the future, it is imperative that new techniques be developed and applied to reduce personnel exposure. Full primary system chemical decontamination technology offers the potential to be single most effective method of maintaining workers exposure {open_quotes}as low as reasonably achievable{close_quotes} (ALARA) while greatly reducing plant operation and maintenance (O&M) costs. A three-phase program underway since 1987, has as its goal to demonstrate that full RCS decontamination is a visible technology to reduce general plant radiation levels without threatening the long term reliability and operability of a plant. This paper discusses research leading to and plans for a National Demonstration of Full RCS Chemical Decontamination at Indian Point 2 nuclear generating station in 1995.

  9. Criteria and evaluation of three decontamination techniques

    Energy Technology Data Exchange (ETDEWEB)

    Tripp, J.L.

    1994-01-01

    Past decontamination and solvent recovery activities at the Idaho Chemical Processing Plant (ICPP), which is part of the Idaho National Engineering Laboratory (INEL), have resulted in the accumulation of 1.5 million gallons of radioactively contaminated sodium-bearing liquid waste. Future decontamination activities at the ICPP could result in the production of 5 million gallons or more of sodium-bearing waste using the current decontamination techniques of chemical/water flushes and steam jet cleaning. This waste requires a large amount of cold chemical additive to process because the low melting temperatures of sodium and potassium salts cause agglomeration in the bed of the calciner vessel. Criteria have been established for evaluating methods and technologies available for decontaminating equipment and facilities. The criteria were weighted according to their relative importance using a Kepner-Tregoe Problem Solving process. These criteria were used to rank three decontamination techniques new to the ICPP: laser ablation, liquid abrasive blasting and CO{sub 2} pellet blasting, against the standard decontamination techniques of sodium-based chemical cleaning and water/steam jets used.

  10. Criteria and evaluation of three decontamination techniques

    International Nuclear Information System (INIS)

    Tripp, J.L.

    1994-01-01

    Past decontamination and solvent recovery activities at the Idaho Chemical Processing Plant (ICPP), which is part of the Idaho National Engineering Laboratory (INEL), have resulted in the accumulation of 1.5 million gallons of radioactively contaminated sodium-bearing liquid waste. Future decontamination activities at the ICPP could result in the production of 5 million gallons or more of sodium-bearing waste using the current decontamination techniques of chemical/water flushes and steam jet cleaning. This waste requires a large amount of cold chemical additive to process because the low melting temperatures of sodium and potassium salts cause agglomeration in the bed of the calciner vessel. Criteria have been established for evaluating methods and technologies available for decontaminating equipment and facilities. The criteria were weighted according to their relative importance using a Kepner-Tregoe Problem Solving process. These criteria were used to rank three decontamination techniques new to the ICPP: laser ablation, liquid abrasive blasting and CO 2 pellet blasting, against the standard decontamination techniques of sodium-based chemical cleaning and water/steam jets used

  11. Corrosion surveillance of the chemical decontamination process in Kuosheng nuclear power plant

    International Nuclear Information System (INIS)

    Wang, L.H.

    2002-01-01

    The Piping Recirculation System (RRS) and reactor water clean-up system (RWCU) of Kuosheng Nuclear Power Plant of Taiwan Power Company were decontaminated by CORD process of Framatome ANP GmbH during the outage at October 2001. This is the first time that CORD process was adopted and applied in Taiwan Nuclear Power Plant. To verify minor corrosion damage and correct process control, the material corrosion condition was monitored during all the stages of the chemical decontamination work. Three kinds of specimen were adopted in this corrosion monitoring, including corrosion coupons for weight loss measurements, electrochemical specimens for on-line corrosion monitoring, and WOL specimens (wedge opening loaded) for stress corrosion evaluation. The measured metal losses from nine coupon materials did not reveal any unexpected or intolerable high corrosion damage from the CORD UV or CORD CS processes. The coupon materials included type 304 stainless steel (SS) with sensitized and as-received thermal history, type 308 weld filler, type CF8 cast SS, nickel base alloy 182 weld filler, Inconel 600, Stellite 6 hard facing alloy, NOREM low cobalt hard facing alloy, and A106B carbon steel (CS). The electrochemical noise (ECN) measurements from three-electrode electrochemical probe precisely depicted the metal corrosion variation with the decontamination process change. Most interestingly, the estimated trend of accumulated metal loss is perfectly corresponding to the total removed activities. The ECN measurements were also used for examining the effect of different SS oxide films pre-formed in NWC and HWC on the decontamination efficiency, and for evaluating the galvanic effect of CS with SS. The existing cracks did not propagate further during the decontamination. The average decontamination factors achieved were 50.8 and 4.2 respectively for RRS and RWCU. (authors)

  12. Some remarks about decontamination

    International Nuclear Information System (INIS)

    Bertini, A.

    1990-01-01

    Decontamination in itself is not the elimination of a problem, but corresponds to move that problem from one place to another. It is beneficial only if the contamination is less of a nuisance when moved to the ''other place''. Therefore any prospective decontamination process is to be considered essentially in terms of cost-benefit, and in particular in terms of reducing the burden on the waste management systems. The paper is not intended to deal with and to review critically the technical aspects of the various decontamination processes which are currently available. Its aim is to call the attention of those who may be faced with the problem of large-scale decontamination, so that this operation is carried out after all practical aspects have been examined. (author)

  13. Chemical stability of reactive skin decontamination lotion (RSDL®).

    Science.gov (United States)

    Bogan, R; Maas, H J; Zimmermann, T

    2018-09-01

    Reactive Skin Decontamination Lotion (RSDL ® ) is used for the decontamination of Chemical Warfare Agents and Toxic Industrial Compounds after dermal exposure. It has to be stockpiled over a long period and is handled in all climatic zones. Therefore stability is an essential matter of concern. In this work we describe a study to the chemical stability of RSDL ® as basis for an estimation of shelf life. We analysed RSDL ® for the active ingredient 2,3-butandione monoxime (diacetylmonooxime, DAM), the putative degradation product dimethylglyoxime (DMG) and unknown degradation products by means of a reversed phase high pressure liquid chromatography (HPLC). Calculations were done according to the Arrhenius equation. Based on the temperature dependent rate constants, the time span was calculated, until defined threshold values for DAM and DMG subject to specification and valid regulations were exceeded. The calculated data were compared to the ones gathered from stockpiled samples and samples exposed during foreign mission. The decline of DAM followed first order kinetics, while formation of DMG could be described by zero order kinetics. The rate constants were distinctively temperature dependent. Calculated data were in good accordance to the measured ones from stockpile and mission. Based on a specified acceptable DAM-content of 90% and a valid threshold value of 0.1% (w/w) for the degradation product DMG, RSDL ® proved to be stable for at least four years if stored at the recommended conditions of 15°C-30°C. If continuously stored at higher temperatures shelf life will decrease markedly. Therefore RSDL ® is an object for risk orientated quality monitoring during storage. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. SAFETY STUDIES TO MEASURE EXOTHERMIC REACTIONS OF SPENT PLUTONIUM DECONTAMINATION CHEMICALS USING WET AND DRY DECONTAMINATION METHODS

    International Nuclear Information System (INIS)

    HOPKINS, A.M.; JACKSON, G.W.; MINETTE, M.; EWALT, J.; COOPER, T.; SCOTT, P.; JONES, S.; SCHEELEY, R.

    2005-01-01

    The Plutonium Finishing Plant (PFP) at the Hanford site in Eastern Washington is currently being decommissioned by Fluor Hanford. Chemicals being considered for dccontamination of gloveboxes in PFP include cerium (IV) nitrate in a nitric acid solution, and proprietary commercial solutions that include acids and sequestering agents. Aggressive chemicals are commonly used to remove transuranic contaminants from process equipment to allow disposal of the equipment as low level waste. Fluor's decontamination procedure involves application of chemical solutions as a spray on the contaminated surfaces, followed by a wipe-down with rags. Alternatively, a process of applying oxidizing Ce IV ions contained in a gel matrix and vacuuming a dry gel material is being evaluated. These processes effectively transfer the transuranic materials to rags or a gel matrix which is then packaged as TRU waste and disposed

  15. New quaternary ammonium salts based decontaminants

    Directory of Open Access Journals (Sweden)

    Diana M. Popescu

    2014-06-01

    Full Text Available Decontamination after terrorist attacks or industrial accidents with biological and/or chemical agents („bio-chem“ must be fast and efficient, in order to reduce the number of victims and to eliminate the consequent damages. The decontamination of living biological agents (bacteria, viruses or nonliving ones (toxins, regulators and toxic chemicals could be accomplished by reactions of hydrolysis in various experimental conditions, in particular in alkaline medium, reactions with amines or ammonia, alcohols, phenols etc. and by their transformation into less toxic degradation products. “Bio-chem” intentional or unintentional contamination is a real risk, towards which an effective management must be available to prevent and control it. Decontamination is an essential measure to protect the personnel and the environment. Synthesis and testing of new „bio-chem“ decontaminants, based on quaternary ammonium salts, complete the arsenal of protection against chemical and biological agents. The most effective selected substances could be produced and used for decontamination in accordance with legal procedures

  16. Cost effectiveness of dilute chemical decontamination

    International Nuclear Information System (INIS)

    Le Surf, J.E.; Weyman, G.D.

    1983-01-01

    The origin and basic principles of the dilute chemical decontamination (DCD) concept are described and illustrated by reference to the CAN-DECON process. The estimated dose savings from the actual application of the process at several reactors are presented and discussed. Two methods of performing a cost/benefit appraisal are described and discussed. This methodology requires more study by the nuclear industry, including collection by station staff of relevant data on which future cost/benefit appraisals may be based. Finally, three illustrative cases are examinated to show the breakeven point and potential savings achievable by DCD with different initial radiation fields and different amounts of work to be done. The overall conclusion is that there are many situations in which DCD is desirable to reduce radiation exposure of workers, to save costs to the station, and to ease the performance of maintenance and repair work on reactor systems

  17. Chemical decontamination of Santa Maria de Garona NPP recirculation loops

    Energy Technology Data Exchange (ETDEWEB)

    Coello, R. [Santa Maria de Garona NPP - NUCLENOR, S.A. (Spain)

    2002-07-01

    Santa Maria de Garona is a boiling water reactor (BWR-3) with a Primary Containment type Mark 1. Its electrical power is 466 Mw and began its commercial operation in 1971. The plant currently operates in 24 month cycles. The reactor water recirculation system (RWRS) is composed of two independent loops. Each of them has a one stage vertical centrifugal recirculation pump, with a nominal flow of 2020 l/s, and ten jet pumps. It is worthy of mention that in 1986 it was started to inject hydrogen into the feedwater (concentration = 0,3 mg/l) in order to implement the chemical condition known as hydrogen water chemistry (HWC) in the primary circuit. The objective was to create an electrochemical potential below -230 mV in the RWRS which is assumed to be low enough to mitigate the intergranular stress corrosion cracking phenomena (IGSCC) in the sensitized austenitic stainless steels. Later, in 1994, the hydrogen concentration in the feedwater was increased to 0,9 mg/l in order to obtain the protection's ECP in the bottom of the reactor vessel. This feedwater hydrogen concentration has been maintained since then. The nature of the oxides that are formed in the RWRS is strongly affected by the electrochemical conditions (ECP) which have been maintained in this system. It is frequent to find oxides like Fe{sub 2}O{sub 3} (hematite), Fe{sub 3}O{sub 4} (magnetite), NiFe{sub 2}O{sub 4} (trevorite), Cr{sub 2} FeO{sub 4} (chromite), Fe{sub 3-x-y} Cr{sub x} Ni{sub y} O{sub 4} (spinels), etc. However, it is normal to find a combination of all of them in various proportions, depending on the ECP established. Radioactive isotopes of the transition metals ({sup 60}Co, {sup 54}Mn, {sup 51}Cr, {sup 59}Fe, etc.) also participate in these oxides and contribute greatly to increase the dose rate in the circuit. The chemical decontamination processes are designed for the effective dissolution of the metallic oxides present and therefore the type of process to be applied will depend

  18. A decontamination system for chemical weapons agents using a liquid solution on a solid sorbent

    International Nuclear Information System (INIS)

    Waysbort, Daniel; McGarvey, David J.; Creasy, William R.; Morrissey, Kevin M.; Hendrickson, David M.; Durst, H. Dupont

    2009-01-01

    A decontamination system for chemical warfare agents was developed and tested that combines a liquid decontamination reagent solution with solid sorbent particles. The components have fewer safety and environmental concerns than traditional chlorine bleach-based products or highly caustic solutions. The liquid solution, based on Decon Green TM , has hydrogen peroxide and a carbonate buffer as active ingredients. The best solid sorbents were found to be a copolymer of ethylene glycol dimethacrylate and n-lauryl methacrylate (Polytrap 6603 Adsorber); or an allyl methacrylate cross-linked polymer (Poly-Pore E200 Adsorber). These solids are human and environmentally friendly and are commonly used in cosmetics. The decontaminant system was tested for reactivity with pinacolyl methylphosphonofluoridate (Soman, GD), bis(2-chloroethyl)sulfide (Mustard, HD), and S-(2-diisopropylaminoethyl) O-ethyl methylphosphonothioate (VX) by using NMR Spectroscopy. Molybdate ion (MoO 4 -2 ) was added to the decontaminant to catalyze the oxidation of HD. The molybdate ion provided a color change from pink to white when the oxidizing capacity of the system was exhausted. The decontaminant was effective for ratios of agent to decontaminant of up to 1:50 for VX (t 1/2 ≤ 4 min), 1:10 for HD (t 1/2 1/2 < 2 min). The vapor concentrations of GD above the dry sorbent and the sorbent with decontamination solution were measured to show that the sorbent decreased the vapor concentration of GD. The E200 sorbent had the additional advantage of absorbing aqueous decontamination solution without the addition of an organic co-solvent such as isopropanol, but the rate depended strongly on mixing for HD

  19. Gross decontamination experiment report

    International Nuclear Information System (INIS)

    Mason, R.; Kinney, K.; Dettorre, J.; Gilbert, V.

    1983-07-01

    A Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI - Unit 2 reactor building in March 1982. The polar crane, D-rings, missile shields, refueling canals, refueling bridges, equipment, and elevations 305' and 347'-6'' were flushed with low pressure water. Additionally, floor surfaces on elevation 305' and floor surfaces and major pieces of equipment on elevation 347'-6'' were sprayed with high pressure water. Selective surfaces were decontaminated with a mechanical scrubber and chemicals. Strippable coating was tested and evaluated on equipment and floor surfaces. The effectiveness, efficiency, and safety of several decontamination techniques were established for the large, complex decontamination effort. Various decontamination equipment was evaluated and its effectiveness was documented. Decontamination training and procedures were documented and evaluated, as were the support system and organization for the experiment

  20. Gross decontamination experiment report

    Energy Technology Data Exchange (ETDEWEB)

    Mason, R.; Kinney, K.; Dettorre, J.; Gilbert, V.

    1983-07-01

    A Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI - Unit 2 reactor building in March 1982. The polar crane, D-rings, missile shields, refueling canals, refueling bridges, equipment, and elevations 305' and 347'-6'' were flushed with low pressure water. Additionally, floor surfaces on elevation 305' and floor surfaces and major pieces of equipment on elevation 347'-6'' were sprayed with high pressure water. Selective surfaces were decontaminated with a mechanical scrubber and chemicals. Strippable coating was tested and evaluated on equipment and floor surfaces. The effectiveness, efficiency, and safety of several decontamination techniques were established for the large, complex decontamination effort. Various decontamination equipment was evaluated and its effectiveness was documented. Decontamination training and procedures were documented and evaluated, as were the support system and organization for the experiment.

  1. Decontamination Efficacy and Skin Toxicity of Two Decontaminants against Bacillus anthracis.

    Directory of Open Access Journals (Sweden)

    Chad W Stratilo

    Full Text Available Decontamination of bacterial endospores such as Bacillus anthracis has traditionally required the use of harsh or caustic chemicals. The aim of this study was to evaluate the efficacy of a chlorine dioxide decontaminant in killing Bacillus anthracis spores in solution and on a human skin simulant (porcine cadaver skin, compared to that of commonly used sodium hypochlorite or soapy water decontamination procedures. In addition, the relative toxicities of these decontaminants were compared in human skin keratinocyte primary cultures. The chlorine dioxide decontaminant was similarly effective to sodium hypochlorite in reducing spore numbers of Bacillus anthracis Ames in liquid suspension after a 10 minute exposure. After five minutes, the chlorine dioxide product was significantly more efficacious. Decontamination of isolated swine skin contaminated with Bacillus anthracis Sterne with the chlorine dioxide product resulted in no viable spores sampled. The toxicity of the chlorine dioxide decontaminant was up to two orders of magnitude less than that of sodium hypochlorite in human skin keratinocyte cultures. In summary, the chlorine dioxide based decontaminant efficiently killed Bacillus anthracis spores in liquid suspension, as well as on isolated swine skin, and was less toxic than sodium hypochlorite in cultures of human skin keratinocytes.

  2. Chemical and Biological Substances Decontamination Study for Mars Missions and Terrestrial Applications

    Science.gov (United States)

    Pottage, Thomas; Walker, James; Bennett, Allan; Vrublevskis, John; Hovland, Scott

    This study, funded by the European Space Agency (ESA) and undertaken by the Health Protec-tion Agency, UK supported by Systems Engineering and Assessment Ltd., was devised to select suitable current decontamination technologies for development for future manned missions to the Moon and Mars. There is a requirement to decontaminate the habitat module due to the concerns about astronaut ill health, microbial deterioration of materials and potential forward contamination in the case of Mars. In the case of the MIR space station, biodeterioration of components and materials occurred, and dangerous levels of airborne microorganisms were detected during air sampling procedures which lead to the introduction of microbial exposure limits (as MORD SSP 50260) to ensure the health of the crew. COSPAR planetary protection guidelines highlight the need to reduce any potential forward or backwards contamination issues that may occur through the use of Extra Vehicular Activity (EVA) suits whilst on Mars. Decontamination of the suit exterior must be completed before any EVA activity on Mars, whilst a further decontamination cycle must be completed after entry to the airlock following EVA. Technologies and techniques have also been investigated for the microbial reduction of the interior surfaces of the EVA suit to stop biodeterioration of the materials and protect the user from pathogenic microbe accumulation. The first work package reviewed the systems description and requirements as detailed in the statement of work. The requirements were broken down into 12 further requirement sections, where they were updated and expanded, resulted in Technical Note (TN) 1 which was then used as the base document for WP2 and WP3. WP2 investigated the current technologies available for the decontamination of the habitat module interior on missions of up to 6 months and missions that have durations of greater than 6 months. A comprehensive review was carried out for the different methods that

  3. Decontamination and decommissioning techniques for research reactors

    International Nuclear Information System (INIS)

    Oh, Won Zin; Won, H. J.; Jung, C. H.; Choi, W. K.; Kim, G. N.; Lee, K. W.

    2002-05-01

    Evaluation of soil decontamination process and the liquid decontamination waste treatment technology are investigation of organic acid as a decontamination agent, investigation of the liquid waste purification process and identification of recycling the decontamination agents. Participation on IAEA CRP meeting are preparation of IAEA technical report on 'studies on decommissioning of TRIGA reactors and site restoration technologies' and exchange the research result, technology, experience and safety regulation of the research reactor D and D of USA, Great Britain, Canada, Belgium, Italy, India and so forth

  4. Decontamination manual of RI handling laboratory

    International Nuclear Information System (INIS)

    Wadachi, Yoshiki

    2004-01-01

    Based on experiences in Japan Atomic Energy Research Institute (JAERI), the essential and practical knowledge of radioactive contamination and its decontamination, and the method and procedure of floor decontamination are described for researcher and managing person in charge of handling radioisotopes (RI) in RI handling laboratories. Essential knowledge concerns the uniqueness of solid surface contamination derived from RI half lives and quantities, surface contamination density limit, and mode/mechanism of contamination. The principle of decontamination is a single conduct with recognition of chemical form of the RI under use. As the practical knowledge, there are physical and chemical methods of solid surface decontamination. The latter involves use of inorganic acids, chelaters and surfactants. Removal and replacement of contaminated solid like floor material are often effective. Distribution mapping of surface contamination can be done by measuring the radioactivity in possibly contaminated areas, and is useful for planning of effective decontamination. Floor surface decontamination is for the partial and spread areas of the floor. It is essential to conduct the decontamination with reagent from the highly to less contaminated areas. Skin decontamination with either neutral detergent or titanium oxide is also described. (N.I.)

  5. Decontamination measures for Fukushima prefecture. Fukushima prefecture measures for promoting decontamination

    International Nuclear Information System (INIS)

    Endo, Kouzou

    2013-01-01

    For Fukushima prefecture having suffered from significant damage associated with the Great East Japan Earthquake and the nuclear power plant accident, the decontamination work is the most urgent issue. The paper reports the present situation of the remediation acts of Fukushima Government done since the accident, particular emphasis on the removal of radioactive substances due to cesium 137 in the residential area. Government supports to promote the decontamination work and its operators, and encourages employers and employees in their efforts, to set up temporary storages of the produced radioactive wastes, to cultivate and improve technical supports for decontamination work and strengthen understanding and support of the local resident, thus providing the training course for the site supervisors, the person engaged in the work and management. (S. Ohno)

  6. Lessons Learned from Decontamination Experiences

    Energy Technology Data Exchange (ETDEWEB)

    Sorensen, JH

    2000-11-16

    This interim report describes a DOE project currently underway to establish what is known about decontamination of buildings and people and the procedures and protocols used to determine when and how people or buildings are considered ''clean'' following decontamination. To fulfill this objective, the study systematically examined reported decontamination experiences to determine what procedures and protocols are currently employed for decontamination, the timeframe involved to initiate and complete the decontamination process, how the contaminants were identified, the problems encountered during the decontamination process, how response efforts of agencies were coordinated, and the perceived social psychological effects on people who were decontaminated or who participated in the decontamination process. Findings and recommendations from the study are intended to aid decision-making and to improve the basis for determining appropriate decontamination protocols for recovery planners and policy makers for responding to chemical and biological events.

  7. A decontamination system for chemical weapons agents using a liquid solution on a solid sorbent

    Energy Technology Data Exchange (ETDEWEB)

    Waysbort, Daniel [Israel Institute for Biological Research, PO Box 19, Ness-Ziona 74100 (Israel); McGarvey, David J. [R and T Directorate, Edgewood Chemical and Biological Center (ECBC), Aberdeen Proving Ground-Edgewood Area, MD 21010 (United States)], E-mail: david.mcgarvey@us.army.mil; Creasy, William R.; Morrissey, Kevin M.; Hendrickson, David M. [SAIC, P.O. Box 68, Gunpowder Branch, Aberdeen Proving Ground, MD 21010 (United States); Durst, H. Dupont [R and T Directorate, Edgewood Chemical and Biological Center (ECBC), Aberdeen Proving Ground-Edgewood Area, MD 21010 (United States)

    2009-01-30

    A decontamination system for chemical warfare agents was developed and tested that combines a liquid decontamination reagent solution with solid sorbent particles. The components have fewer safety and environmental concerns than traditional chlorine bleach-based products or highly caustic solutions. The liquid solution, based on Decon Green{sup TM}, has hydrogen peroxide and a carbonate buffer as active ingredients. The best solid sorbents were found to be a copolymer of ethylene glycol dimethacrylate and n-lauryl methacrylate (Polytrap 6603 Adsorber); or an allyl methacrylate cross-linked polymer (Poly-Pore E200 Adsorber). These solids are human and environmentally friendly and are commonly used in cosmetics. The decontaminant system was tested for reactivity with pinacolyl methylphosphonofluoridate (Soman, GD), bis(2-chloroethyl)sulfide (Mustard, HD), and S-(2-diisopropylaminoethyl) O-ethyl methylphosphonothioate (VX) by using NMR Spectroscopy. Molybdate ion (MoO{sub 4}{sup -2}) was added to the decontaminant to catalyze the oxidation of HD. The molybdate ion provided a color change from pink to white when the oxidizing capacity of the system was exhausted. The decontaminant was effective for ratios of agent to decontaminant of up to 1:50 for VX (t{sub 1/2} {<=} 4 min), 1:10 for HD (t{sub 1/2} < 2 min with molybdate), and 1:10 for GD (t{sub 1/2} < 2 min). The vapor concentrations of GD above the dry sorbent and the sorbent with decontamination solution were measured to show that the sorbent decreased the vapor concentration of GD. The E200 sorbent had the additional advantage of absorbing aqueous decontamination solution without the addition of an organic co-solvent such as isopropanol, but the rate depended strongly on mixing for HD.

  8. Determination of trace amounts of chemical warfare agent degradation products in decontamination solutions with NMR spectroscopy.

    Science.gov (United States)

    Koskela, Harri; Rapinoja, Marja-Leena; Kuitunen, Marja-Leena; Vanninen, Paula

    2007-12-01

    Decontamination solutions are used for an efficient detoxification of chemical warfare agents (CWAs). As these solutions can be composed of strong alkaline chemicals with hydrolyzing and oxidizing properties, the analysis of CWA degradation products in trace levels from these solutions imposes a challenge for any analytical technique. Here, we present results of application of nuclear magnetic resonance spectroscopy for analysis of trace amounts of CWA degradation products in several untreated decontamination solutions. Degradation products of the nerve agents sarin, soman, and VX were selectively monitored with substantially reduced interference of background signals by 1D 1H-31P heteronuclear single quantum coherence (HSQC) spectrometry. The detection limit of the chemicals was at the low part-per-million level (2-10 microg/mL) in all studied solutions. In addition, the concentration of the degradation products was obtained with sufficient confidence with external standards.

  9. Post-Decontamination Vapor Sampling and Analytical Test Methods

    Science.gov (United States)

    2015-08-12

    is decontaminated that could pose an exposure hazard to unprotected personnel. The chemical contaminants may include chemical warfare agents (CWAs... decontamination process. Chemical contaminants can include chemical warfare agents (CWAs) or their simulants, nontraditional agents (NTAs), toxic industrial...a range of test articles from coupons, panels, and small fielded equipment items. 15. SUBJECT TERMS Vapor hazard; vapor sampling; chemical warfare

  10. Presolidification treatment of decontamination wastes

    International Nuclear Information System (INIS)

    Habayeb, M.A.

    1982-02-01

    Unsatisfactory leaching performance of several solidified decontamination solutions indicated a need for presolidification treatments to reduce the water sensitivity of the active chemicals. Chemical treatments examined in this work include pH adjustment, precipitation and oxidation-reduction reactions. The reactions involved in these treatments are discussed. The most suitable presolidification treatment for each decontamination solution has been identified. Further research is needed to test the effectivenss of these treatments

  11. Long lasting decontamination foam

    Science.gov (United States)

    Demmer, Ricky L.; Peterman, Dean R.; Tripp, Julia L.; Cooper, David C.; Wright, Karen E.

    2010-12-07

    Compositions and methods for decontaminating surfaces are disclosed. More specifically, compositions and methods for decontamination using a composition capable of generating a long lasting foam are disclosed. Compositions may include a surfactant and gelatin and have a pH of less than about 6. Such compositions may further include affinity-shifting chemicals. Methods may include decontaminating a contaminated surface with a composition or a foam that may include a surfactant and gelatin and have a pH of less than about 6.

  12. Treatability Studies Used to Test for Exothermic Reactions of Plutonium Decontamination Chemicals

    Energy Technology Data Exchange (ETDEWEB)

    Ewalt, John R.; Minette, Michael J.; Hopkins, Andrea M.; Cooper, Thurman D.; Simiele, Connie J.; Scott, Paul A.; Scheele, Randall D.; Charboneau, Stacy L.

    2005-08-07

    Fluor Hanford is decommissioning the PFP at the Hanford Site and is considering using agressive chemicals to remove transuranium contaminants. As part of the evaluation of these methods, Fluor is considering the path for disposal and the thermal stability of the waste products from the decontamination process. This paper provides the results of our studies on cerium nitrate and RadPro(TM), a nitric acid based complexant.

  13. Concrete decontamination scoping tests

    International Nuclear Information System (INIS)

    Archibald, K.E.

    1995-01-01

    This report details the research efforts and scoping tests performed at the Idaho Chemical Process Plant using scabbling, chemical, and electro-osmotic decontamination techniques on radiologically contaminated concrete

  14. Health physics and industrial hygiene aspects of decontamination as a precursor to decontamination

    International Nuclear Information System (INIS)

    Card, C.J.; Hoenes, G.R.; Munson, L.F.; Halseth, G.A.

    1982-06-01

    The Pacific Northwest Laboratory is conducting a comprehensive study of the impacts, benefits and effects of decontamination as a precursor to decommissioning for the US Nuclear Regulatory Commission. The program deals primarily with chemical cleaning of light-water reactor (LWR) systems that will not be returned to operation. A major section of this study defines the health physics and industrial hygiene and safety concerns during decontamination operations. The primary health physics concerns include providing adequate protection for workers from radiation sources which are transported by the decontamination processes, estimating and limiting radioactive effluents to the environment and maintaining operations in accordance with the ALARA philosophy. Locating and identifying the areas of contamination and measuring the radiation exposure rates throughout the reactor primary system are fundamental to implementing these health physics goals. The principal industrial hygiene and safety concerns stem from the fact that a nuclear power plant is being converted for a time to a chemical plant which will contain large volumes of chemical solutions

  15. Influence of Decontamination

    International Nuclear Information System (INIS)

    Knaack, Michael

    2016-01-01

    This paper describes the influence of several decontamination techniques on the decommissioning of nuclear facilities. There are different kinds of decontamination methods like mechanical and chemical processes. The techniques specified, and their potential to change measured characteristics like the isotope vector of the contamination is demonstrated. It is common for all these processes, that the contamination is removed from the surface. Slightly adhered nuclides can be removed more effectively than strongly sticking nuclides. Usually a mixture of these nuclides forms the contamination. Problematically any kind of decontamination will influence the nuclide distribution and the isotope vector. On the one hand it is helpful to know the nuclide distribution and the isotope vector for the radiological characterization of the nuclear facility and on the other hand this information will be changed in the decontamination process. This is important especially for free release procedures, radiation protection and waste management. Some questions on the need of decontamination have been discussed. (authors)

  16. Effect of gamma irradiation on microbial decontamination, and chemical and sensory characteristic of lycium fruit

    Energy Technology Data Exchange (ETDEWEB)

    Wen, H.-W. [Department of Food Science and Technology, Cornell University, Geneva, NY 14456 (United States); Chung, H.-P. [Nuclear Science and Technology Development Center, National Tsing Hua University, Hsinchu, Taiwan (China); Chou, F.-I. [Nuclear Science and Technology Development Center, National Tsing Hua University, Hsinchu, Taiwan (China)]. E-mail: fichou@mx.nthu.edu.tw; Lin, I-H. [Committee on Chinese Medicine and Pharmacy, Department of Health, Executive Yuan, Taiwan (China); Hsieh, P.-C. [Committee on Chinese Medicine and Pharmacy, Department of Health, Executive Yuan, Taiwan (China)

    2006-05-15

    Lycium fruit, popular traditional Chinese medicine and food supplement generally is ingested uncooked, was exposed to several doses of gamma irradiation (0-14 kGy) to evaluate decontamination efficiency, changes in chemical composition, and changes in sensory characteristic. In this study, lycium fruit specimens contained microbial counts of 3.1x10{sup 3}-1.7x10{sup 5} CFU/g and 14 kGy was sufficient for microbial decontamination. Before irradiation, the main microbe isolated from lycium fruit was identified as a strain of yeast, Cryptococcus laurentii. After 10 kGy of irradiation, a Gram-positive spore-forming bacterium, Bacillus cereus, was the only survivor. The first 90% reduction (LD{sub 9}) of C. laurentii and B. cereus was approximately 0.6 and 6.5 kGy, respectively, the D{sub 1} doses of C. laurentii and B. cereus was approximately 0.6 and 1.7 kGy, respectively. After 14 kGy irradiation, except the vitamin C content, other chemical composition (e.g., crude protein, {beta}-carotene, riboflavin, fructose, etc.) and the sensory characteristic of lycium fruit specimens did not have significant changes. In conclusion, 14 kGy is the optimal decontamination dose for lycium fruit for retention of its sensory quality and extension of shelf life.

  17. Effect of gamma irradiation on microbial decontamination, and chemical and sensory characteristic of lycium fruit

    International Nuclear Information System (INIS)

    Wen, H.-W.; Chung, H.-P.; Chou, F.-I.; Lin, I-H.; Hsieh, P.-C.

    2006-01-01

    Lycium fruit, popular traditional Chinese medicine and food supplement generally is ingested uncooked, was exposed to several doses of gamma irradiation (0-14 kGy) to evaluate decontamination efficiency, changes in chemical composition, and changes in sensory characteristic. In this study, lycium fruit specimens contained microbial counts of 3.1x10 3 -1.7x10 5 CFU/g and 14 kGy was sufficient for microbial decontamination. Before irradiation, the main microbe isolated from lycium fruit was identified as a strain of yeast, Cryptococcus laurentii. After 10 kGy of irradiation, a Gram-positive spore-forming bacterium, Bacillus cereus, was the only survivor. The first 90% reduction (LD 9 ) of C. laurentii and B. cereus was approximately 0.6 and 6.5 kGy, respectively, the D 1 doses of C. laurentii and B. cereus was approximately 0.6 and 1.7 kGy, respectively. After 14 kGy irradiation, except the vitamin C content, other chemical composition (e.g., crude protein, β-carotene, riboflavin, fructose, etc.) and the sensory characteristic of lycium fruit specimens did not have significant changes. In conclusion, 14 kGy is the optimal decontamination dose for lycium fruit for retention of its sensory quality and extension of shelf life

  18. Decontamination of radioactive isotopes

    International Nuclear Information System (INIS)

    Despotovic, R.; Music, S.; Subotic, B.; Wolf, R.H.H.

    1979-01-01

    Removal of radioactive isotopes under controlled conditions is determined by a number of physical and chemical properties considered radiocontaminating and by the characteristics of the contaminated object. Determination of quantitative and qualitative factors for equilibrium in a contamination-decontamination system provides the basis for rational and successful decontamination. The decontamination of various ''solid/liquid'' systems is interesting from the scientific and technological point of view. These systems are of great importance in radiation protection (decontamination of various surfaces, liquids, drinking water, fixation or collection of radiocontaminants). Different types of decontamination systems are discussed. The dependence of rate and efficiency of the preparation conditions and on the ageing of the scavenger is described. The influence of coagulating electrolyte on radioactive isotope fixation efficiency was also determined. The fixation of fission radionuclide on oxide scavengers has been studied. The connection between fundamental investigations and practical decontamination of the ''solid/liquid'' systems is discussed. (author)

  19. Developments in Decontamination Technologies of Military Personnel and Equipment

    Science.gov (United States)

    Sata, Utkarsh R.; Ramkumar, Seshadri S.

    Individual protection is important for warfighters, first responders and civilians to meet the current threat of toxic chemicals and chemical warfare (CW) agents. Within the realm of individual protection, decontamination of warfare agents is not only required on the battlefield but also in laboratory, pilot plants, production and agent destruction sites. It is of high importance to evaluate various decontaminants and decontamination techniques for implementing the best practices in varying scenarios such as decontamination of personnel, sites and sensitive equipment.

  20. Large-Scale Urban Decontamination; Developments, Historical Examples and Lessons Learned

    Energy Technology Data Exchange (ETDEWEB)

    Rick Demmer

    2007-02-01

    Recent terrorist threats and actual events have lead to a renewed interest in the technical field of large scale, urban environment decontamination. One of the driving forces for this interest is the real potential for the cleanup and removal of radioactive dispersal device (RDD or “dirty bomb”) residues. In response the U. S. Government has spent many millions of dollars investigating RDD contamination and novel decontamination methodologies. Interest in chemical and biological (CB) cleanup has also peaked with the threat of terrorist action like the anthrax attack at the Hart Senate Office Building and with catastrophic natural events such as Hurricane Katrina. The efficiency of cleanup response will be improved with these new developments and a better understanding of the “old reliable” methodologies. Perhaps the most interesting area of investigation for large area decontamination is that of the RDD. While primarily an economic and psychological weapon, the need to cleanup and return valuable or culturally significant resources to the public is nonetheless valid. Several private companies, universities and National Laboratories are currently developing novel RDD cleanup technologies. Because of its longstanding association with radioactive facilities, the U. S. Department of Energy National Laboratories are at the forefront in developing and testing new RDD decontamination methods. However, such cleanup technologies are likely to be fairly task specific; while many different contamination mechanisms, substrate and environmental conditions will make actual application more complicated. Some major efforts have also been made to model potential contamination, to evaluate both old and new decontamination techniques and to assess their readiness for use. Non-radioactive, CB threats each have unique decontamination challenges and recent events have provided some examples. The U. S. Environmental Protection Agency (EPA), as lead agency for these emergency

  1. Chemical decontamination for decommissioning purposes. (Vigorous decontamination tests of steel samples in a special test loop)

    International Nuclear Information System (INIS)

    Bregani, F.; Pascali, R.; Rizzi, R.

    1984-01-01

    The aim of the research activities described was to develop vigorous decontamination techniques for decommissioning purposes, taking into account the cost of treatment of the radwaste, to achieve possibly unrestricted release of the treated components, and to obtain know-how for in situ hard decontamination. The decontamination procedures for strong decontamination have been optimized in static and dynamic tests (DECO-loop). The best values have been found for: (i) hydrochloric acid: 4 to 5% vol. at low temperature, 0.7 to 1% vol. at high temperature (80 0 C); (ii) hydrofluoric plus nitric acid: 1.5% vol. HF + 5% vol. HNO 3 at low temperature; 0.3 to 0.5% vol. HF + 2.5 to 5% vol. HNO 3 at high temperature. High flow rates are not necessary, but a good re-circulation of the solution is needed. The final contamination levels, after total oxide removal, are in accordance with limits indicated for unrestricted release of materials in some countries. The arising of the secondary waste is estimated. Decontamination of a 10 m 2 surface would typically produce 0.5 to 3.0 kg of dry waste, corresponding to 1.6 to 10 kg of concrete conditioned waste

  2. Long-term decontamination engineering study. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Geuther, W.J.

    1995-04-03

    This report was prepared by Westinghouse Hanford Company (WHC) with technical and cost estimating support from Pacific Northwest Laboratories (PNL) and Parsons Environmental Services, Inc. (Parsons). This engineering study evaluates the requirements and alternatives for decontamination/treatment of contaminated equipment at the Hanford Site. The purpose of this study is to determine the decontamination/treatment strategy that best supports the Hanford Site environmental restoration mission. It describes the potential waste streams requiring treatment or decontamination, develops the alternatives under consideration establishes the criteria for comparison, evaluates the alternatives, and draws conclusions (i.e., the optimum strategy for decontamination). Although two primary alternatives are discussed, this study does identify other alternatives that may warrant additional study. hanford Site solid waste management program activities include storage, special processing, decontamination/treatment, and disposal facilities. This study focuses on the decontamination/treatment processes (e.g., waste decontamination, size reduction, immobilization, and packaging) that support the environmental restoration mission at the Hanford Site.

  3. Long-term decontamination engineering study. Volume 1

    International Nuclear Information System (INIS)

    Geuther, W.J.

    1995-01-01

    This report was prepared by Westinghouse Hanford Company (WHC) with technical and cost estimating support from Pacific Northwest Laboratories (PNL) and Parsons Environmental Services, Inc. (Parsons). This engineering study evaluates the requirements and alternatives for decontamination/treatment of contaminated equipment at the Hanford Site. The purpose of this study is to determine the decontamination/treatment strategy that best supports the Hanford Site environmental restoration mission. It describes the potential waste streams requiring treatment or decontamination, develops the alternatives under consideration establishes the criteria for comparison, evaluates the alternatives, and draws conclusions (i.e., the optimum strategy for decontamination). Although two primary alternatives are discussed, this study does identify other alternatives that may warrant additional study. hanford Site solid waste management program activities include storage, special processing, decontamination/treatment, and disposal facilities. This study focuses on the decontamination/treatment processes (e.g., waste decontamination, size reduction, immobilization, and packaging) that support the environmental restoration mission at the Hanford Site

  4. DECONTAMINATION TECHNOLOGIES FOR FACILITY REUSE

    International Nuclear Information System (INIS)

    Bossart, Steven J.; Blair, Danielle M.

    2003-01-01

    As nuclear research and production facilities across the U.S. Department of Energy (DOE) nuclear weapons complex are slated for deactivation and decommissioning (D and D), there is a need to decontaminate some facilities for reuse for another mission or continued use for the same mission. Improved technologies available in the commercial sector and tested by the DOE can help solve the DOE's decontamination problems. Decontamination technologies include mechanical methods, such as shaving, scabbling, and blasting; application of chemicals; biological methods; and electrochemical techniques. Materials to be decontaminated are primarily concrete or metal. Concrete materials include walls, floors, ceilings, bio-shields, and fuel pools. Metallic materials include structural steel, valves, pipes, gloveboxes, reactors, and other equipment. Porous materials such as concrete can be contaminated throughout their structure, although contamination in concrete normally resides in the top quarter-inch below the surface. Metals are normally only contaminated on the surface. Contamination includes a variety of alpha, beta, and gamma-emitting radionuclides and can sometimes include heavy metals and organic contamination regulated by the Resource Conservation and Recovery Act (RCRA). This paper describes several advanced mechanical, chemical, and other methods to decontaminate structures, equipment, and materials

  5. Decontaminating products for routine decontamination in nuclear power plants

    International Nuclear Information System (INIS)

    Henning, K.

    2001-01-01

    Routine decontamination work that has to be carried out in practical operation includes the cleaning of all kinds of surfaces such as floors, walls and apparatus, the decontamination of professional clothes and of the personnel. In order to ensure a trouble-free functioning of plants for the treatment of waste water and concentrate in nuclear power plants, radioactive liquid wastes appearing in the controlled area should be compatible with the treatment methods in practice. Radioactive concentrates and resides obtained from the treatment methods are mixed with matrix materials like cement or bitumen or treated by roller frame drying and thus are conditioned for intermediate or final storage. Several requirements should be made on decontaminating agents used in the controlled area. Some of these physical-chemical criteria will be described in detail. (R.P.)

  6. Decontamination of Chemical/Biological Warfare (CBW) Agents Using an Atmospheric Pressure Plasma Jet (APPJ)

    Science.gov (United States)

    Herrmann, Hans W.

    1998-11-01

    The atmospheric pressure plasma jet (APPJ) is a non-thermal, high pressure, uniform glow discharge that produces a high velocity effluent stream of highly reactive chemical species. The discharge operates on a feedstock gas (e.g. He/O_2/H_2O) which flows between an outer, grounded, cylindrical electrode and an inner, coaxial electrode powered at 13.56 MHz RF. While passing through the plasma, the feedgas becomes excited, dissociated or ionized by electron impact. Once the gas exits the discharge volume, ions and electrons are rapidly lost by recombination, but the fast-flowing effluent still contains metastables (e.g. O2*, He*) and radicals (e.g. O, OH). These reactive species have been shown to be effective neutralizers of surrogates for anthrax spores, mustard blister agent and VX nerve gas. Unlike conventional, wet decontamination methods, the plasma effluent does not cause corrosion of most surfaces and does not damage wiring, electronics, nor most plastics. This makes it highly suitable for decontamination of high value sensitive equipment such as is found in vehicle interiors (i.e. tanks, planes...) for which there is currently no good decontamination technique. Furthermore, the reactive species rapidly degrade into harmless products leaving no lingering residue or harmful byproducts. Physics of the APPJ will be discussed and results of surface decontamination experiments using simulant and actual CBW agents will be presented.

  7. Improvement of solvents for chemical decontamination: nickel ferrites removal

    International Nuclear Information System (INIS)

    Figueroa, Carlos A.; Morando, Pedro J.; Blesa, Miguel A.

    1999-01-01

    Carboxylic acids are usually included in commercial solvents for the chemical cleaning and decontamination of metal surfaces from the oxide layers grown and/or deposited from high temperature water by corrosive process. In particular oxalic acid is included in second path of AP-Citrox method. However, in some cases, their use shows low efficiency. This fact is attributed to the special passivity of the mixed oxides as nickel ferrites. This work reports a kinetic study of dissolution of a synthetic nickel ferrite (NiFe 2 O 4 ) confronted with simple oxides (NiO and Fe 2 O 3 ) in mineral acids and oxalic acid. The dissolution factor and reaction rate were determined in several conditions (reactive concentrations, pH and added ferrous ions). Experimental data of dissolution (with and without Fe(II) added) show a congruent kinetic regime. Pure nickel oxide (NiO) is rather resistant to the attack by oxalic acid solutions, and ferrous ions do not accelerate dissolution. In fact, nickel oxide dissolves better by oxidative attack that takes advantage of the higher lability of Ni 3+ . It may be concluded that oxalic acid operates to dissolve iron, and the ensuing disruption of the solid framework accelerates the release of nickel. Our results point to use more reactive solvents in iron from mixed oxides and to the possibility of using one stage decontamination method. (author)

  8. Results of chemical decontamination of DOE`s uranium-enrichment scrap metal

    Energy Technology Data Exchange (ETDEWEB)

    Levesque, R.G.

    1997-02-01

    The CORPEX{reg_sign} Nuclear Decontamination Processes were used to decontaminate representative scrap metal specimens obtained from the existing scrap metal piles located at the Department of Energy (DOE) Portsmouth Gaseous Diffusion Plant (PORTS), Piketon, Ohio. In September 1995, under contract to Lockheed Martin Energy Systems, MELE Associates, Inc. performed the on-site decontamination demonstration. The decontamination demonstration proved that significant amounts of the existing DOE scrap metal can be decontaminated to levels where the scrap metal could be economically released by DOE for beneficial reuse. This simple and environmentally friendly process can be used as an alternative, or in addition to, smelting radiologically contaminated scrap metal.

  9. Decontamination flowsheet development for a waste oil containing mixed radioactive contaminants

    International Nuclear Information System (INIS)

    Vijayan, S.; Buckley, L.P.

    1993-01-01

    The majority of waste oils contaminated with both radioactive and hazardous components are generated in nuclear power plant, research lab. and uranium-refinery operations. The waste oils are complex, requiring a detailed examination of the waste management strategies and technology options. It may appear that incineration offers a total solution, but this may not be true in all cases. An alternative approach is to decontaminate the waste oils to very low contaminant levels, so that the treated oils can be reused, burned as fuel in boilers, or disposed of by commercial incineration. This paper presents selected experimental data and evaluation results gathered during the development of a decontamination flowsheet for a specific waste oil stores at Chalk River Labs. (CRL). The waste oil contains varying amounts of lube oils, grease, paint, water, particulates, sludge, light chloro- and fluoro-solvents, polychlorinated biphenyls (PCB), complexing chemicals, uranium, chromium, iron, arsenic and manganese. To achieve safe management of this radioactive and hazardous waste, several treatment and disposal methods were screened. Key experiments were performed at the laboratory-scale to confirm and select the most appropriate waste-management scheme based on technical, environmental and economic criteria. The waste-oil-decontamination flowsheet uses a combination of unit operations, including prefiltration, acid scrubbing, and aqueous-leachage treatment by precipitation, microfiltration, filter pressing and carbon adsorption. The decontaminated oil containing open-quotes de minimisclose quotes levels of contaminants will undergo chemical destruction of PCBs and final disposal by incineration. The recovered uranium will be recycled to a uranium milling process

  10. Recent developments in collaborative CBRN decontamination science : a retrospective

    Energy Technology Data Exchange (ETDEWEB)

    Yanofsky, N. [Defence Research and Development Canada, Ottawa, ON (Canada); Volchek, K.; Fingas, M. [Environment Canada, Ottawa, ON (Canada). Emergencies Science and Technology Division, Environmental Technology Centre, Science and Technology Branch; Filatov, B. [Research Inst. of Hygiene, Toxicology and Occupational Pathology, Volgograd (Russian Federation)

    2006-07-01

    The importance of addressing the risk of chemical, biological and radiological/nuclear (CBRN) attacks was discussed with particular reference to recent developments in Canadian-led decontamination studies as part of the remediation response to a terrorist attack. Research efforts have been supported by government programs such as the CBRN Research and Technology Initiative of Defence Research and Development Canada and the Global Partnership Program of the Department of Foreign Affairs. In 2005, Environment Canada and Defence Research and Development Canada co-organized an international workshop with the Research Institute of Health, Toxicology and Occupational Pathology of Volgograd, Russia. The workshop brought together researchers from Canada, Russia, United States, United Kingdom, Netherlands, Poland and Bulgaria, with the view to eventually develop longer term collaborations. The theme focused on membrane technology and its application in CBRN decontamination. This paper reviewed these collaborative and international research efforts and identified areas in need of future work, such as bioremediation and radio-nuclear remediation. It addressed issues supporting a collaborative international research agenda in decontamination science; membrane filtration as a feasible approach to decontamination waste treatment; and possible areas of CBRN collaboration. It was suggested that the key to successful decontamination requires the creation of computer systems for the initial identification of chemical substances; complete toxicological characterization of the most dangerous agents; regulatory safety standards; quantitative determination of chemical substances; antidotes for most chemical threat agents; universal decontamination agents; and, validation of criteria for decontaminating buildings. The question of who pays for decontamination, be it the private or public sector, was also discussed.

  11. Efficacy studies of Reactive Skin Decontamination Lotion, M291 Skin Decontamination Kit, 0.5% bleach, 1% soapy water, and Skin Exposure Reduction Paste Against Chemical Warfare Agents, part 2: guinea pigs challenged with soman.

    Science.gov (United States)

    Braue, Ernest H; Smith, Kelly H; Doxzon, Bryce F; Lumpkin, Horace L; Clarkson, Edward D

    2011-03-01

    This report, the second in a series of five, directly compares the efficacy of Reactive Skin Decontamination Lotion (RSDL), the M291 Skin Decontamination Kit (SDK), 0.5% bleach (sodium or calcium hypochlorite solution), 1% soapy water, and Skin Exposure Reduction Paste Against Chemical Warfare Agents (SERPACWA) in the haired guinea pig model following exposure to soman (GD). In all experiments, guinea pigs were close-clipped and given anesthesia. In the decontamination experiments, the animals were challenged with GD and decontaminated after a 2-minute delay for the standard procedure or at longer times for the delayed-decontamination experiments. Positive control animals were challenged with GD in the same manner as the treated animals, except that they received no treatment. All animals were observed during the first 4 hours and again at 24 hours after exposure for signs of toxicity and death. The protective ratio (PR, defined as the median lethal dose [LD(50)] of the treatment group divided by the LD(50) of the untreated positive control animals) was calculated from the derived probit dose-response curves established for each treatment group and nontreated control animals. SERPACWA was applied as a thin coating (0.1 mm thick), allowed to dry for 15 minutes, and challenged with GD. After a 2-hour challenge, any remaining GD was blotted off the animal, but no additional decontamination was done. Significance in this report is defined as p decontamination experiments, the calculated PRs for RSDL, 0.5% bleach, 1% soapy water, and M291 SDK were 14, 2.7, 2.2, and 2.6, respectively. RSDL was by far the most effective decontamination product tested and significantly better than any of the other products. Bleach, soapy water, and the M291 SDK provided equivalent and modest protection. Since only RSDL provided at least good protection (PR > 5), it was the only decontamination product evaluated for delayed decontamination. In the GD delayed-decontamination experiments

  12. Nuclear decontamination

    International Nuclear Information System (INIS)

    LeSurf, J.E.

    1981-01-01

    Decontamination may be accomplished by chemical, electrical, or mechanical means. Recently there have been significant developments in all three categories as well as an increased tendency to combine techniques, either simultaneously (e.g. by adding chemicals to water jets) or sequentially (e.g. by using a mechanical method to remove loose contamination, followed by a chemical method for more tightly bound activity). Some developments in the different techniques are discussed, together with typical applications of each. (author)

  13. Decontamination of process equipment using recyclable chelating solvent

    International Nuclear Information System (INIS)

    Jevec, J.; Lenore, C.; Ulbricht, S.

    1995-01-01

    The Department of Energy (DOE) is now faced with the task of meeting decontamination and decommissioning obligations at numerous facilities by the year 2019. Due to the tremendous volume of material involved, innovative decontamination technologies are being sought that can reduce the volumes of contaminated waste materials and secondary wastes requiring disposal. With sufficient decontamination, some of the material from DOE facilities could be released as scrap into the commercial sector for recycle, thereby reducing the volume of radioactive waste requiring disposal. Although recycling may initially prove to be more costly than current disposal practices, rapidly increasing disposal costs are expected to make recycling more and more cost effective. Additionally, recycling is now perceived as the ethical choice in a world where the consequences of replacing resources and throwing away reusable materials are impacting the well-being of the environment. Current approaches to the decontamination of metals most often involve one of four basic process types: (1) chemical, (2) manual and mechanical, (3) electrochemical, and (4) ultrasonic. open-quotes Hardclose quotes chemical decontamination solutions, capable of achieving decontamination factors (Df's) of 50 to 100, generally involve reagent concentrations in excess of 5%, tend to physically degrade the surface treated, and generate relatively large volumes of secondary waste. open-quotes Softclose quotes chemical decontamination solutions, capable of achieving Df's of 5 to 10, normally consist of reagents at concentrations of 0.1 to 1%, generally leave treated surfaces in a usable condition, and generate relatively low secondary waste volumes. Under contract to the Department of Energy, the Babcock ampersand Wilcox Company is developing a chemical decontamination process using chelating agents to remove uranium compounds and other actinide species from process equipment

  14. Thorough Chemical Decontamination with the MEDOC Process : Batch Treatment of Dismantled Pieces or Loop Treatment of Large Components Such as the BR3 Steam Generator and Pressurizer

    International Nuclear Information System (INIS)

    Ponnet, M.; Klein, M.; Massaut, V.; Davain, H.; Aleton, G.

    2003-01-01

    The dismantling of the BR3-PWR reactor leads to the production of large masses of contaminated metallic pieces, including structural materials, primary pipings, tanks and heat exchangers. One of our main objectives is to demonstrate that we can minimize the volume of radioactive waste in an economical way, by the use of alternative waste routes, such as the clearance of materials after thorough decontamination. The SCKoCEN uses its own developed chemical decontamination process, so-called MEDOC (Metal Decontamination by Oxidation with Cerium), based on the use of cerium IV as strong oxidant in sulphuric acid with continuous regeneration using ozone. An industrial installation has been designed and constructed in close collaboration with Framatome-ANP (France). This installation started operation in September 1999 for the treatment of the metallic pieces arising from the dismantling of the BR3 reactor. Since then, more than 25 tons of contaminated material including primary pipes have been treated batchwise with success. 75 % of material could be directly cleared after treatment (Activity lower than 0.1 Bq/g for 60Co) and the other 25% free released after melting activity. The SCKoCEN performed in April 2002 the closed loop decontamination of the BR3 Steam Generator by connection of the MEDOC plant after few adaptations. The decontamination was done within 30 cycles in 3 weeks with consecutive steps like decontamination steps (injection of the solution into the SG) and regeneration steps with ozone. In total, 60 hours of decontamination at 70 C and 130 hours of regeneration were needed to reach the objectives. The tube bundle (600 m2) was attacked and about 10 (micro)m representing more than 41 kg of stainless steel and 2.06 GBq of 60Co was dissolved into the solution. The residual contamination measurements made directly into the water box are still going on, however it seems that the objective to reach the free release criteria after melting is achieved. The next

  15. Development of decontamination methods

    International Nuclear Information System (INIS)

    Kunze, S.; Dippel, T.; Hentschel, D.

    1976-01-01

    PVC floorings, fabricated by mixing of the basic components, showed no relation between content of fillers and decontamination results. Decontamination results are partly poorer, if the flooring contains a high concentration of the filler, especially if the latter consists mainly of hydrophilic materials. The coloring of the floorings seems to have no influence on the decontamination. Rubber floorings, fabricated by chemical reactions between polymers, vulcanization materials and fillers, show decontamination results depending definitely from the proper choice of the filler. Flooring types, containing lampblack, graphite, kaoline, barium sulfate and titanium oxide are easy to decontaminate. Increasing contents of hydrophilic filler cause a fall off in the decontamination results. The decontamination effectiveness and the homogenity of cleaning pastes based on hydrochloric acid, nitric acid, titanium oxide and polyethylene powders is strongly depended on the content of hydrochloric acid. Reduction of the content of this component to less than 2 w/O remains the effectiveness unchanged only if the titanium oxide-polyethylene powder mixture is substituted by a high density, highly surface active powder material. This type of paste containing no hydrochloric acid shows nearly the same decontamination effectiveness as standard pickling pastes containing about 30% hydrochlorid acid. Properly prepared salt powder turn out to be easily and successfully applied to metal surfaces by a flame spray technique. The thin layer of molten salts is a very effective decontamination to samples contaminated in the primary loop of a PWR. (orig.) [de

  16. Decontamination and decommissioning of the Chemical Process Cell (CPC): Topical report for the period January 1985-March 1987

    International Nuclear Information System (INIS)

    Meigs, R.A.

    1987-07-01

    To support interim storage of vitrified High-Level Waste (HLW) at the West Valley Demonstration Project, the shielded, remotely operated Chemical Process Cell (CPC) was decommissioned and decontaminated. All equipment was removed, packaged and stored for future size reduction and decontamination. Floor debris was sampled, characterized, and vacuumed into remotely handled containers. The cell walls, ceiling, and floor were decontaminated. Three 20 Mg (22.5 ton) concrete neutron absorber cores were cut with a high-pressure water/abrasive jet cutting system and packaged for disposal. All operations were performed remotely using two overhead bridge cranes which included two 1.8 Mg (2 ton) hoists, one 14.5 Mg (16 ton) hoist, and an electromechanical manipulator or an industrial robot mounted on a mobile platform. Initial general area dose rates in the cell ranged from 1 to 50 R/h. Target levels of less than 10 mR/h general area readings were established before decontamination and decommissioning was initiated; general area dose rates between 200 mR/h and 1200 mR/h were obtained at the completion of the decontamination work. 4 refs., 11 figs., 8 tabs

  17. Decontamination of TRU glove boxes

    International Nuclear Information System (INIS)

    Crawford, J.H.

    1978-03-01

    Two glove boxes that had been used for work with transuranic nuclides (TRU) for about 12 years were decontaminated in a test program to collect data for developing a decontamination facility for large equipment highly contaminated with alpha emitters. A simple chemical technique consisting of a cycle of water flushes and alkaline permanganate and oxalic acid washes was used for both boxes. The test showed that glove boxes and similar equipment that are grossly contaminated with transuranic nuclides can be decontaminated to the current DIE nonretrievable disposal guide of <10 nCi TRU/g with a moderate amount of decontamination solution and manpower. Decontamination of the first box from an estimated 1.3 Ci to about 5 mCi (6 nCi/g) required 1.3 gallons of decontamination solution and 0.03 man-hour of work for each square foot of surface area. The second box was decontaminated from an estimated 3.4 Ci to about 2.8 mCi (4.2 nCi/g) using 0.9 gallon of decontamination solution and 0.02 man-hour for each square foot of surface area. Further reductions in contamination were achieved by repetitive decontamination cycles, but the effectiveness of the technique decreased sharply after the initial cycle

  18. Development of haemostatic decontaminants for treatment of wounds contaminated with chemical warfare agents. 3: Evaluation of in vitro topical decontamination efficacy using damaged skin.

    Science.gov (United States)

    Lydon, Helen L; Hall, Charlotte A; Dalton, Christopher H; Chipman, J Kevin; Graham, John S; Chilcott, Robert P

    2017-08-01

    Previous studies have demonstrated that haemostatic products with an absorptive mechanism of action retain their clotting efficiency in the presence of toxic materials and are effective in decontaminating chemical warfare (CW) agents when applied to normal, intact skin. The purpose of this in vitro study was to assess three candidate haemostatic products for effectiveness in the decontamination of superficially damaged porcine skin exposed to the radiolabelled CW agents, soman (GD), VX and sulphur mustard (HD). Controlled physical damage (removal of the upper 100 μm skin layer) resulted in a significant enhancement of the dermal absorption of all three CW agents. Of the haemostatic products assessed, WoundStat™ was consistently the most effective, being equivalent in performance to a standard military decontaminant (fuller's earth). These data suggest that judicious application of haemostatic products to wounds contaminated with CW agents may be a viable option for the clinical management of casualties presenting with contaminated, haemorrhaging injuries. Further studies using a relevant animal model are required to confirm the potential clinical efficacy of WoundStat™ for treating wounds contaminated with CW agents. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Skin decontamination: principles and perspectives.

    Science.gov (United States)

    Chan, Heidi P; Zhai, Hongbo; Hui, Xiaoying; Maibach, Howard I

    2013-11-01

    Skin decontamination is the primary intervention needed in chemical, biological and radiological exposures, involving immediate removal of the contaminant from the skin performed in the most efficient way. The most readily available decontamination system on a practical basis is washing with soap and water or water only. Timely use of flushing with copious amounts of water may physically remove the contaminant. However, this traditional method may not be completely effective, and contaminants left on the skin after traditional washing procedures can have toxic consequences. This article focuses on the principles and practices of skin decontamination.

  20. Chemical decontamination of reactor components

    International Nuclear Information System (INIS)

    Riess, R.; Berthold, H.O.

    1977-08-01

    A solution for the decontamination of reactor components of the primary system was developed. This solution is a modification of the APAC- (Alkaline Permanganate Ammonium Citrate) system described in the literature. The most important advantage of the present solution over the APAC-method is that it does not induce any selective corrosion attack on materials like stainless steel (austenitic), Inconel 600 and Incoloy 800. (orig.) [de

  1. Atmospheric-pressure plasma decontamination/sterilization chamber

    Science.gov (United States)

    Herrmann, Hans W.; Selwyn, Gary S.

    2001-01-01

    An atmospheric-pressure plasma decontamination/sterilization chamber is described. The apparatus is useful for decontaminating sensitive equipment and materials, such as electronics, optics and national treasures, which have been contaminated with chemical and/or biological warfare agents, such as anthrax, mustard blistering agent, VX nerve gas, and the like. There is currently no acceptable procedure for decontaminating such equipment. The apparatus may also be used for sterilization in the medical and food industries. Items to be decontaminated or sterilized are supported inside the chamber. Reactive gases containing atomic and metastable oxygen species are generated by an atmospheric-pressure plasma discharge in a He/O.sub.2 mixture and directed into the region of these items resulting in chemical reaction between the reactive species and organic substances. This reaction typically kills and/or neutralizes the contamination without damaging most equipment and materials. The plasma gases are recirculated through a closed-loop system to minimize the loss of helium and the possibility of escape of aerosolized harmful substances.

  2. Electrochemical Decontamination of Painted and Heavily Corroded Metals

    International Nuclear Information System (INIS)

    Marczak, S.; Anderson, J.; Dziewinski, J.

    1998-01-01

    The radioactive metal wastes that are generated from nuclear fuel plants and radiochemical laboratories are mainly contaminated by the surface deposition of radioactive isotopes. There are presently several techniques used in removing surface contamination involving physical and chemical processes. However, there has been very little research done in the area of soiled, heavily oxidized, and painted metals. Researchers at Los Alamos National Laboratory have been developing electrochemical procedures for the decontamination of bare and painted metal objects. These methods have been found to be effective on highly corroded as well as relatively new metals. This study has been successful in decontaminating projectiles and shrapnel excavated during environmental restoration projects after 40+ years of exposure to the elements. Heavily corroded augers used in sampling activities throughout the area were also successfully decontaminated. This process has demonstrated its effectiveness and offers several advantages over the present metal decontamination practices of media blasting and chemical solvents. These advantages include the addition of no toxic or hazardous chemicals, low operating temperature and pressure, and easily scaleable equipment. It is in their future plans to use this process in the decontamination of gloveboxes destined for disposal as TRU waste

  3. Assessment of skin exposure to N,N-dimethylformamide and methyl ethylketone through chemical protective gloves and decontamination of gloves for reuse purposes.

    Science.gov (United States)

    Chao, Keh-Ping; Wang, Ping; Chen, Chen-Peng; Tang, Ping-Yu

    2011-02-15

    N,N-dimethylformamide (DMF) and methyl ethylketone (MEK) are the hazardous chemicals commonly used in the synthetic leather industries. Although chemical protective gloves provide adequate skin exposure protection to workers in these industries, there is currently no clear guideline or understanding with regard to the use duration of these gloves. In this study, the permeation of DMF/MEK mixture through neoprene gloves and the desorption of chemicals from contaminated gloves were conducted using the ASTM F739 cell. The acceptable use duration time of the gloves against DMF/MEK permeation was estimated by assuming a critical body burden of chemical exposure as a result of dermal absorption. In a re-exposure cycle of 5 days, decontamination of the gloves by aeration at 25°C was found to be inadequate in a reduction of breakthrough time as compared to a new unexposed glove. However, decontamination of the gloves by heating at 70 or 100°C showed that the protective coefficient of the exposed gloves had similar levels of resistance to DMF/MEK as that of new gloves. Implications of this study include an understanding of the use duration of neoprene gloves and proper decontamination of chemical protective gloves for reuse. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Decontamination of polyvinylchloride- and rubber type flooring

    International Nuclear Information System (INIS)

    Kunze, S.

    1975-01-01

    These types, fabricated by mixing of the basic components, showed no relation between content of fillers and decontamination results. Decontamination results are partly poorer, if the flooring contains a high concentration of the filler, especially if the latter consists mainly of hydrophilic materials. The coloring of the floorings seems to have no influence on the decontamination but floorings with clearly separated patterns can not be recommended for nuclear facilities. Fabricated by chemical reactions between polymeres, vulcanization materials and fillers, the decontamination results depend definitely from the proper choice of the filler. Flooring types, containing lampblack, graphite, kaoline, barium sulfate and titanium oxide are easy to decontamine. Again, increasing contents of hydrophilic filler cause a fall off in the decontamination results. (orig.) [de

  5. Effect of Cerium(IV)-Surfactant Reaction in Foam Decontamination

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Han Beom; Jung, Chong-Hun; Yoon, In-Ho; Kim, Chorong; Choi, Wang-Kyu [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    Using foams allows the decommissioning of complex shaped facilities. The decontamination foam comprises at least one surfactant to generate the foam and one or more chemical reactants to achieve the dissolution of the contaminants at the solid surface. In order to improve the efficiency of decontamination foam, the present study attempts to find the optimum condition of chemical reagents to the foaming solution. The corrosion rate of radioactive nuclides contaminated stainless steel metal is very important factor for the foam decontamination process. The goal of this study is to develop the decontamination process for contaminated stainless steel in medium of nitric acid. Stainless steel needs a strong oxidizing agent such as Ce(IV) ion and the effects of cerium(IV). Surfactant interaction involved in foam decontamination and finally the improvement brought by formulation science. The formulation of foams loaded with strong oxidizing reagents such as Ce(IV) is an important factor. The enhanced decontamination properties of nitric acid with Ce(IV) additive on stainless steel is well known in liquid mediums. stainless steel metal is an important aspect in the foam decontamination process.

  6. Effect of Cerium(IV)-Surfactant Reaction in Foam Decontamination

    International Nuclear Information System (INIS)

    Yang, Han Beom; Jung, Chong-Hun; Yoon, In-Ho; Kim, Chorong; Choi, Wang-Kyu

    2015-01-01

    Using foams allows the decommissioning of complex shaped facilities. The decontamination foam comprises at least one surfactant to generate the foam and one or more chemical reactants to achieve the dissolution of the contaminants at the solid surface. In order to improve the efficiency of decontamination foam, the present study attempts to find the optimum condition of chemical reagents to the foaming solution. The corrosion rate of radioactive nuclides contaminated stainless steel metal is very important factor for the foam decontamination process. The goal of this study is to develop the decontamination process for contaminated stainless steel in medium of nitric acid. Stainless steel needs a strong oxidizing agent such as Ce(IV) ion and the effects of cerium(IV). Surfactant interaction involved in foam decontamination and finally the improvement brought by formulation science. The formulation of foams loaded with strong oxidizing reagents such as Ce(IV) is an important factor. The enhanced decontamination properties of nitric acid with Ce(IV) additive on stainless steel is well known in liquid mediums. stainless steel metal is an important aspect in the foam decontamination process

  7. Technical Improvements to an Absorbing Supergel for Radiological Decontamination in Tropical Environments

    Energy Technology Data Exchange (ETDEWEB)

    Kaminski, Michael D. [Argonne National Lab. (ANL), Argonne, IL (United States); Mertz, Carol J. [Argonne National Lab. (ANL), Argonne, IL (United States); Kivenas, Nadia [Argonne National Lab. (ANL), Argonne, IL (United States); demmer, Rick [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-01-01

    Argonne National Laboratory (Argonne) developed a superabsorbing gel-based process (SuperGel) for the decontamination of cesium from concrete and other porous building materials. Here, we report on results that tested the gel decontamination technology on specific concrete and ceramic formulations from a coastal city in Southeast Asia, which may differ significantly from some U.S. sources. Results are given for the evaluation of americium and cesium sequestering agents that are commercially available at a reasonable cost; the evaluation of a new SuperGel formulation that combines the decontamination properties of cesium and americium; the variation of the contamination concentration to determine the effects on the decontamination factors with concrete, tile, and brick samples; and pilot-scale testing (0.02–0.09 m2 or 6–12 in. square coupons).

  8. Systems analysis of decontamination options for civilian vehicles.

    Energy Technology Data Exchange (ETDEWEB)

    Foltz, Greg W.; Hoette, Trisha Marie

    2010-11-01

    The objective of this project, which was supported by the Department of Homeland Security (DHS) Science and Technology Directorate (S&T) Chemical and Biological Division (CBD), was to investigate options for the decontamination of the exteriors and interiors of vehicles in the civilian setting in order to restore those vehicles to normal use following the release of a highly toxic chemical. The decontamination of vehicles is especially challenging because they often contain sensitive electronic equipment, multiple materials some of which strongly adsorb chemical agents, and in the case of aircraft, have very rigid material compatibility requirements (i.e., they cannot be exposed to reagents that may cause even minor corrosion). A systems analysis approach was taken examine existing and future civilian vehicle decontamination capabilities.

  9. Efficacy studies of Reactive Skin Decontamination Lotion, M291 Skin Decontamination Kit, 0.5% bleach, 1% soapy water, and Skin Exposure Reduction Paste Against Chemical Warfare Agents, part 1: guinea pigs challenged with VX.

    Science.gov (United States)

    Braue, Ernest H; Smith, Kelly H; Doxzon, Bryce F; Lumpkin, Horace L; Clarkson, Edward D

    2011-03-01

    This report, first in a series of five, directly compares the efficacy of 4 decontamination products and Skin Exposure Reduction Paste Against Chemical Warfare Agents (SERPACWA) in the haired guinea pig model following exposure to VX. In all experiments, guinea pigs were close-clipped and given anesthesia. In the decontamination experiments, the animals were challenged with VX and decontaminated after a 2-minute delay for the standard procedure or at longer times for the delayed-decontamination experiments. Skin Exposure Reduction Paste Against Chemical Warfare Agents was applied as a thin coating (0.1 mm thick), allowed to dry for 15 minutes, and challenged with VX. After a 2-hour challenge, any remaining VX was blotted off the animal, but no additional decontamination was done. Positive control animals were challenged with VX in the same manner as the treated animals, except that they received no treatment. In addition, the positive control animals were always challenged with 5% VX in isopropyl alcohol (IPA) solution, whereas the treatment animals received either neat (undiluted) VX or 5% VX in IPA solution. All animals were observed during the first 4 hours and again at 24 hours after exposure for signs of toxicity and death. The protective ratio (PR, defined as the median lethal dose [LD(50)] of the treatment group divided by the LD(50) of the untreated positive control animals) was calculated from the probit dose-response curves established for each treatment group and nontreated control animals. Significance in this report was defined as p decontamination experiments, the calculated PRs for Reactive Skin Decontamination Lotion (RSDL), 0.5% bleach, 1% soapy water, and the M291 Skin Decontamination Kit (SDK) were 66, 17, 16, and 1.1, respectively. Reactive Skin Decontamination Lotion was by far the most effective decontamination product tested and was significantly better than any of the other products. Bleach and soapy water provided equivalent and good (PR

  10. Structural characterization of chemical warfare agent degradation products in decontamination solutions with proton band-selective (1)H-(31)P NMR spectroscopy.

    Science.gov (United States)

    Koskela, Harri; Hakala, Ullastiina; Vanninen, Paula

    2010-06-15

    Decontamination solutions, which are usually composed of strong alkaline chemicals, are used for efficient detoxification of chemical warfare agents (CWAs). The analysis of CWA degradation products directly in decontamination solutions is challenging due to the nature of the matrix. Furthermore, occasionally an unforeseen degradation pathway can result in degradation products which could be eluded to in standard analyses. Here, we present the results of the application of proton band-selective (1)H-(31)P NMR spectroscopy, i.e., band-selective 1D (1)H-(31)P heteronuclear single quantum coherence (HSQC) and band-selective 2D (1)H-(31)P HSQC-total correlation spectroscopy (TOCSY), for ester side chain characterization of organophosphorus nerve agent degradation products in decontamination solutions. The viability of the approach is demonstrated with a test mixture of typical degradation products of nerve agents sarin, soman, and VX. The proton band-selective (1)H-(31)P NMR spectroscopy is also applied in characterization of unusual degradation products of VX in GDS 2000 solution.

  11. Liquid abrasive grit blasting literature search and decontamination scoping tests report

    International Nuclear Information System (INIS)

    Ferguson, R.L.

    1993-10-01

    Past decontamination and solvent recovery activities at the Idaho Chemical Processing Plant (ICPP) have resulted in the accumulation of 1.5 million gallons of radioactively contaminated sodium-bearing liquid waste. Future decontamination activities at the ICPP could result in the production of 5 million gallons or more of sodium-bearing waste using the current decontamination techniques of chemical/water flushes and steam jet cleaning. With the curtailment of reprocessing at the ICPP, the focus of decontamination is shifting from maintenance for continued operation of the facilities to decommissioning. As decommissioning plans are developed, new decontamination methods must be used which result in higher decontamination factors and generate lower amounts of sodium-bearing secondary waste. The primary initiative of the WINCO Decontamination Development Program is the development of methods to eliminate/minimize the use of sodium-bearing decontamination chemicals. One method that was chosen for cold scoping studies during FY-93 was abrasive grit blasting. Abrasive grit blasting has been used in many industries and a vast amount of research and development has already been conducted. However, new grits, process improvements and ICPP applicability was investigated. This evaluation report is a summary of the research efforts and scoping tests using the liquid abrasive grit blasting decontamination technique. The purpose of these scoping tests was to determine the effectiveness of three different abrasive grits: plastic beads, glass beads and alumina oxide

  12. Radioactive contamination of some rubber or plastic surfaces by fission products. Decontamination tests

    International Nuclear Information System (INIS)

    Mestre, E.; Sautiez, N.

    1957-10-01

    With the objective of notably addressing the contamination and decontamination of gloves and floor covering, this report first presents some characteristics of contaminating radioactive materials (nature, physical and chemical condition), of contaminated surfaces (surface condition, surface nature), and of decontamination processes (physical, chemical or mechanical action). It describes the operational modality implemented to test decontamination processes on various glove or flooring materials: sample preparation, counting, decontamination, reproducibility of decontamination tests, results in terms of activity reduction. It more precisely describes the tested samples: short gloves, gloves from glove boxes, floor and wall coverings. Results are presented and discussed in terms of sample susceptibility to contamination, and of decontamination, but also for re-contamination tests after a Nab-based decontamination (susceptibility to contamination, decontamination gain)

  13. Comparative scrub solution tests for decontamination of transuranic radionuclides from soils

    International Nuclear Information System (INIS)

    Stevens, J.R.; Kochen, R.L.; Rutherford, D.W.; Riordan, G.A.; Delaney, I.C.

    1982-08-01

    Soil decontamination tests were done using three scrubbing solutions on five different transuranic-contaminated soils from Department of Energy sites. The soils came from Rocky Flats, Colorado; Hanford, Washington; Mound Facility, Ohio; Idaho National Engineering Laboratory, Idaho; and Los Alamos National Laboratory, New Mexico. Decontamination was effected by physical and chemical means. A pH 12.5 scrub effected decontamination by serving as a hydraulic grading and attrition scrub medium; this solution did not solubilize the actinide contamination. A 2% HNO 3 , 0.2% HF, 2% pine oil, and 5% Calgon solution effected decontamination by physical and chemical means; this solution solubilized particulate actinide and actinide dispersed on the surface of soil particles. A 2N HCl scrub was also used to effect decontamination by physical and chemical means; this reagent solubilized soil constituents, removing contamination that had migrated into mineral surfaces. Only Rocky Flats soil was effectively decontaminated by the high pH solution although all soils had an enrichment of the activity in the -150 mesh fraction. Attrition scrubbing with both acid solutions had a better decontamination ability for the +150 mesh fraction for Hanford, INEL, and LANL soils. In addition, the acid solutions solubilized some of the plutonium and had a decontamination effect on the fine fractions

  14. Full system decontamination feasibility studies

    International Nuclear Information System (INIS)

    Denault, R.P.; LeSurf, J.E.; Walschot, F.W.

    1988-01-01

    Many chemical decontaminations have been performed on subsystems in light water reactors (BWRs and PWRs) but none on the full system (including the fuel) of large, (>500 MWe) investor owned reactors. Full system decontaminations on pressure-tubed reactors have been shown to facilitate maintenance, inspection, repair and replacement of reactor components. Further advantages are increased reactor availability and plant life extension. A conceptual study has been performed for EPRI (for PWRs) and Commonwealth Edison Co (for BWRs) into the applicability and cost benefit of full system decontaminations (FSD). The joint study showed that FSDs in both PWRs and BWRs, with or without the fuel included in the decontamination, are feasible and cost beneficial provided a large amount of work is to be done following the decontamination. The large amounts of radioactive waste generated can be managed using current technologies. Considerable improvements in waste handling, and consequent cost savings, can be obtained if new techniques which are now reaching commercial application are used. (author)

  15. Soil decontamination criteria report, November 1980

    International Nuclear Information System (INIS)

    Riordan, G.A.

    1980-01-01

    A program to access the extent of transuranic soil contamination at DOE sites and to develop methods for their decontamination is underway at Rocky Flats. As part of this program, acceptable soil contamination levels for plutonium proposed by a number of authorities over the past couple of decades were reviewed. From this review, goals for soil decontamination work are proposed. These goals, which relate to the disposition of the products of a decontamination process, are summarized as follows (dpm/g will refer to disintegrations per minute of transuranic nuclides per gram of soil): soil fractions having less than 30 dpm can be disposed of as surface soil with unrestricted usage. Fine soil fractions (less than 100 μm) that have less than 500 dpm and coarse soil fractions that have less than 1000 dpm can be disposed of as subsurface soil as long as usage is controlled to ensure compliance with EPA dosage guidance. Soil concentrates that have an activity greater than the above values but less than 22,000 dpm should be interred in an approved, low level waste burial site. Soil concentrates that are greater than 22,000 dpm should be stored as retrievable waste. Changes in the technical and legal areas of soil decontamination are rapid. Permissible soil decontamination levels will change as will decontamination technology and the ability to monitor the effectiveness of the decontamination processes. As a result, annual updates of decontamination criteria, goals, and monitoring are expected

  16. An experimental study on decontamination by surface condition

    International Nuclear Information System (INIS)

    Lee, Young Hae

    1974-01-01

    Surface decontamination is one of the very important problem to be completely solved in the isotope laboratory where there is always the possibility of radioactive contamination, i.e., on the floors, walls, working tables and benches etc., Isotope laboratories require surface covering of material which can be easily and effectively decontaminated. These experiment were done to find an effective decontamination procedure for kind of surfaces which usually are found in radioisotope laboratories and the best type of surface material, that is, one which is easily decontaminated from the point of view of radiation health and safely. This study is presented to guide radioisotope laboratories in Korea which may need to renovate existing unsafe facilities. In some contaminated facilities entirely new installations may be required. Twelve types of surface material are used for study in this experiment. These include 10 cm square of stainless steel, aluminum, ceramic and mosaic tiles, glass, acrylic, formica board, asphalt tile and coated wood with 4 kinds of paints. Stepwise decontamination was performed with various decontamination procedures following a spill of I 1 31 on the center of the surface material being tested. Twelve different decontamination procedures were tested. These included wet wiping with water and detergent, or dry wiping, or removing with gummed paper. Additional chemical procedures used 10% solution of hydrochloric acid, or surface acid, or ammonium citrate, or potassium iodide, or acetone or carbon tetrachloride. The final testing method was abrasion of the test surfaces. Brief analysis of experimental results on the decontaminability on the tested surface showed: 1. Metallic surfaces such as stainless steel or aluminum, or glass, or a piece of ceramic tile or acrylic are recommended as the surface materials for isotope laboratories because these are easily decontaminated by wet wiping only. 2. Formica board, asphalt tile and wood are not easily

  17. CO2 pellet blasting literature search and decontamination scoping tests report

    International Nuclear Information System (INIS)

    Archibald, K.E.

    1993-12-01

    Past decontamination and solvent recovery activities at the Idaho Chemical Processing Plant (ICPP) have resulted in the accumulation of 1.5 million gallons of radioactively contaminated sodium-bearing liquid waste. Future decontamination activities at the ICPP could result in the production of 5 million gallons or more of sodium-bearing waste using current decontamination techniques. Chemical decontamination flushes have provided a satisfactory level of decontamination. However, this method generates large amounts of sodium-bearing secondary waste. Steam jet cleaning has also been used with a great deal of success but cannot be used on concrete or soft materials. With the curtailment of reprocessing at the ICPP, the focus of decontamination is shifting from maintenance for continued operation of the facilities to decommissioning. Treatment of sodium-bearing waste is a particularly difficult problem due to the high content of alkali metals in the sodium-bearing liquid waste. It requires a very large volume of cold chemical additive for calcination. In addition, the sodium content of the sodium-bearing waste exceeds the limit that can be incorporated into vitrified waste without the addition of glass-forming compounds (primarily silicon) to produce an acceptable immobilized waste form. The primary initiatives of the Decontamination Development Program is the development of methods to eliminate/minimize the use of sodium-bearing decontamination chemicals and to minimize all liquid decontamination wastes. One method chosen for cold scoping studies during FY-93 was CO 2 pellet blasting. CO 2 pellet blasting has been used extensively by commercial industries for general cleaning. However, using this method for decontamination of nuclear materials is a fairly new concept. The following report discusses the research and scoping tests completed on CO 2 pellet blasting

  18. Reducing the Risks. In the aftermath of a terrorist attack, wastewater utilities may have to contend with decontamination water containing chemical, biological, or radiological substances

    International Nuclear Information System (INIS)

    Warren, Linda P.; Hornback, Chris; Strom, Daniel J.

    2006-01-01

    In the aftermath of a chemical, biological, or radiological (CBR) attack, decontamination of people and infrastructure will be needed. Decontamination inevitably produces wastewater, and wastewater treatment plants (WTPs) need to know how to handle decontamination wastewater. This article describes CBR substances; planning, coordinating, and communicating responses across agencies; planning within a utility; coordination with local emergency managers and first responders; mitigating effects of decontamination wastewater; and mitigating effects on utility personnel. Planning for Decontamination Wastewater: A Guide for Utilities, the document on which this article is based, was developed under a cooperative agreement from the U.S. Environmental Protection Agency by the National Association of Clean Water Agencies (NACWA) and its contractor, CH2MHILL, Inc.

  19. Decontamination and decommission of a radiochemical laboratory building complex

    International Nuclear Information System (INIS)

    Zoubek, Norbert

    2008-01-01

    Full text: Handling of unsealed radioactive substances for research and development purposes in chemical or pharmaceutical industries or research centres as well as production of radioactive substances (e.g. for applications in nuclear medicine or industry) requires operation of special radiochemical laboratories. In general, operation of radiochemical laboratories is strongly regulated by the government and national authorities. The operator needs a permit related to radiological protection. In general, technical requirements for such facilities are very high. To ensure high safety standards with respect to the employees and the environment, several radiological protection measures have to be taken. These measures (for example special shielding or ventilation and waste water systems) depend on various factors, e.g. activity in use, kind of nuclides, chemical properties and volatility of substances. In order to close-down such radiochemical laboratories some radiological protection measures have to be maintained to ensure protection of both humans and the environment induced by possible residual contaminations within the facility including technical inventory. However, a later reuse of the facility as a non-radioactive facility requires removal of all radioactive contamination with respect to national regulation. Resulting radioactive wastes have to be disposed of under control of competent authorities. Based on the experience of a decontamination and decommission project for a former radiochemical laboratory complex, the main steps necessary to release such a facility are discussed. Analytical aspects of initial conditions, necessary organisational structures within the project, resources needed estimation and exploration of the radiological situation in the laboratory, elaboration of a measuring strategy and decontamination methods as well as different waste disposal routes in relation to different waste types are reported. (author)

  20. ORNL decontamination and decommissioning program

    International Nuclear Information System (INIS)

    Bell, J.P.

    1980-01-01

    A program has been initiated at ORNL to decontaminate and decommission surplus or abandoned nuclear facilities. Program planning and technical studies have been performed by UCC-ND Engineering. A feasibility study for decommissioning the Metal Recovery Facility, a fuel reprocessing pilot plant, has been completed

  1. Specific decontamination methods: water nozzle, cavitation erosion

    International Nuclear Information System (INIS)

    Boulitrop, D.; Gauchon, J.P.; Lecoffre, Y.

    1984-05-01

    The erosion and decontamination tests carried out in the framework of this study, allowed to specify the fields favourable to the use of the high pressure jet taking into account the determinant parameters that are the pressure and the target-nozzle distance. The previous spraying of gels with chemical reagents (sulfuric acid anf hydrazine) allows to get better decontamination factors. Then, the feasibility study of a decontamination method by cavitation erosion is presented. Gelled compounds for decontamination have been developed; their decontamination quality has been evaluated by comparative contamination tests in laboratory and decontamination tests of samples of materials used in nuclear industry; this last method is adapted to remote handling devices and produces a low quantity of secondary effluents, so it allows to clean high contaminated installation on the site without additional exposure of the personnel [fr

  2. Radioactive contamination of some rubber or plastic surfaces by fission products. Decontamination tests; Contamination radioactive de quelques surfaces en caoutchouc ou en matiere plastique par des produits de fission. Essais de decontamination

    Energy Technology Data Exchange (ETDEWEB)

    Mestre, E.; Sautiez, N.

    1957-10-15

    With the objective of notably addressing the contamination and decontamination of gloves and floor covering, this report first presents some characteristics of contaminating radioactive materials (nature, physical and chemical condition), of contaminated surfaces (surface condition, surface nature), and of decontamination processes (physical, chemical or mechanical action). It describes the operational modality implemented to test decontamination processes on various glove or flooring materials: sample preparation, counting, decontamination, reproducibility of decontamination tests, results in terms of activity reduction. It more precisely describes the tested samples: short gloves, gloves from glove boxes, floor and wall coverings. Results are presented and discussed in terms of sample susceptibility to contamination, and of decontamination, but also for re-contamination tests after a Nab-based decontamination (susceptibility to contamination, decontamination gain)

  3. Development of strippable gel for surface decontamination applications

    International Nuclear Information System (INIS)

    Banerjee, D.; Sandhya, U.; Khot, S.A.; Srinivas, C.

    2015-07-01

    Strippable gels are an attractive option for decontamination of surfaces particularly when materials are to be reused after decontamination. The process in general results in good decontamination performance with minimal secondary waste generation. This paper reports on development of strippable gel formulation using polyvinyl alcohol as the gel former. Peeling behavior of the gel film improved when glycerol was used as plasticizer. Incorporation of decontaminating agents is essential for the gel to be effective, so a number of decontaminating agents were screened based on their miscibility with the gel, smooth peeling, and good decontamination performance. Based on this study, a strippable gel, ‘INDIGEL’ was formulated as a potential candidate for surface decontamination applications. Extensive trials on evaluation of decontamination performance of Indigel were done on simulated surfaces like stainless steel tray, stainless steel fume hood, PVC floor, granite and ceramic table tops. Results show that Indigel is highly effective for decontamination of surfaces contaminated with all types of radionuclides. Simplicity of its use coupled with good decontamination ability will find application in nuclear and other chemical industries. (author)

  4. Decontamination and materials corrosion concerns in the BWR

    International Nuclear Information System (INIS)

    Gordon, B.M.; Gordon, G.M.

    1988-01-01

    The qualification of chemical decontamination processes to decontaminate complete systems or individual components in essential if effective inspection, maintenance, repair or replacement of plant components is to be achieved with minimum exposure of workers to ionizing radiation. However, it is critical that the benefits of decontamination processes are not overshadowed by deleterious materials/ corrosion side effects during the application of the process or during subsequent operation. This paper discusses such potential corrosion/materials problems in the BWR and presents relevant available corrosion data for the various commercial decontamination processes. (author)

  5. Development and design application of cerium (IV) decontamination process

    International Nuclear Information System (INIS)

    Bray, L.A.; Seay, J.M.

    1988-01-01

    A simple and effective method was developed for decontamination of high-level waste canisters. This method of chemical decontamination is applicable to a wide variety of contaminated equipment found in the nuclear industry. Conceptual design of the cerium [Ce(IV)] decontamination process equipment has been completed for the West Valley Demonstration project (WVDP) vitrification facility. This remote equipment, which is the first engineering scale application of this technology, will remove surface contamination from stainless-steel (SS) containers containing high-level waste (HLW) glass prior to placing them into temporary storage and ultimate shipment to a U.S. Department of Energy (DOE) repository for disposal. The objective of the development and design study was to identify an effective chemical process and to design equipment to decontaminate the HLW glass canisters to limits that meet U.S. DOE requirements. The equipment includes canister-capping and smear stations in addition to the decontamination module and associated services

  6. Development and design application of cerium (IV) decontamination process

    International Nuclear Information System (INIS)

    Bray, L.A.; Seay, J.M.

    1988-10-01

    A simple and effective method was developed for decontamination of high-level waste canisters. This method of chemical decontamination is applicable to a wide variety of contaminated equipment found in the nuclear industry. Conceptual design of the cerium [Ce(IV)] decontamination process equipment has been completed for the West Valley Demonstration Project (WVDP) vitrification facility. This remote equipment, which is the first engineering scale application of this technology, will remove surface contamination from stainless-steel (SS) containers containing high-level waste (HLW) glass prior to placing them into temporary storage and ultimate shipment to a US Department of Energy (DOE) repository for disposal. The objective of the development and design study was to identify an effective chemical process and to design equipment to decontaminate the HLW glass canisters to limits that meet USDOE requirements. The equipment includes canister-capping and smear stations in addition to the decontamination module and associated services. 2 refs., 1 fig

  7. A Survey and Evaluation of Chemical Warfare Agent-Decontaminants and Decontamination

    Science.gov (United States)

    1984-10-15

    Biological Methods. The use of a cell-free enzymatic system, microorganisms, algae, and the state-of-the-art genetic engineering approach for decontaminating...many organic and inorganic materials might react with agents in a manner similar to complex enzymatic reactions. However. experimental data were not...28). XXCC3 was further tested for use in a microencapsulation concept. Pre- liminary results indicated that O.30g of ethyl cellulose 21 microcapsules

  8. Report on practical use of new decontamination technology

    International Nuclear Information System (INIS)

    Nitta, Hideyuki; Ono, Masahiro

    2000-03-01

    For removing surface contamination of a solid waste with radioactivity, technology of laser cleaning and vacuum arc cleaning has the possibility to obtain the high decontamination rate. We made a research for practical uses of these methods as a new cleaning technology from published papers and patents. From these results, we discussed about an applicability of laser cleaning and vacuum arc cleaning to decontaminate a body of centrifugal separator. At first, we investigate the solid surface cleaning technology with a laser or a vacuum arc from published papers in the world and the patents in Japan. The results were listed in tables. Each information was abstracted into a technical data sheet and sorted into a related technology (system or equipment). We also investigate the decontamination technology by the same way and the results were abstracted into technical data sheets and sorted into related technologies, too. As an application of the above research, we considered the process and the system for decontaminating a body of centrifugal separators (cylinders). In the system, the cleaning head is set inside the cylinder and the inner surface contaminated by radioactivity is removed by the irradiation of a YAG laser, a CO2 laser or a vacuum arc. The cylinder is rotated by rotational rings and moved towards the direction of the central axis and the whole inner surface of the cylinder is cleaned with a constant cleaning rate. We also estimated the costs of each decontamination technology. (author)

  9. Iron-montmorillonite clays as active sorbents for the decontamination of hazardous chemical warfare agents.

    Science.gov (United States)

    Carniato, F; Bisio, C; Evangelisti, C; Psaro, R; Dal Santo, V; Costenaro, D; Marchese, L; Guidotti, M

    2018-02-27

    A class of heterogeneous catalysts based on commercial bentonite from natural origin, containing at least 80 wt% of montmorillonite clay, was designed to transform selectively and under mild conditions toxic organosulfur and organophosphorus chemical warfare agents into non-noxious products with a reduced impact on health and environment. The bentonite from the natural origin was modified by introducing iron species and acid sites in the interlayer space, aiming to obtain a sorbent with strong catalytic oxidising and hydrolytic properties. The catalytic performance of these materials was evaluated in the oxidative abatement of (2-chloroethyl)ethyl sulfide (CEES), a simulant of sulfur mustard, in the presence of aqueous hydrogen peroxide as an oxidant. A new decontamination formulation was, moreover, proposed and obtained by mixing sodium perborate, as a solid oxidant, to iron-bentonite catalysts. Solid-phase decontamination tests, performed on a cotton textile support contaminated with organosulfide and organophosphonate simulant agents revealed the good activity of the solid formulation, especially in the in situ detoxification of blistering agents. Tests carried out on the real blistering warfare agent, sulfur mustard (HD agent), showed that, thanks to the co-presence of the iron-based clay together with the solid oxidant component, a good decontamination of the test surface from the real warfare agent could be achieved (80% contaminant degradation, under ambient conditions, in 24 h).

  10. Decontamination and free release of reactor pond furniture

    International Nuclear Information System (INIS)

    Burke, S.P.; Sanders, M.J.

    1993-01-01

    As part of the Stage 1 decommissioning project for the Steam Generating Heavy Water Reactor (SGHWR) at AEA Technology's Winfrith site in the UK, the 20 fuel racks in the fuel pond are to be removed. At Winfrith, considerable experience of waste disposal via the free release (below regulatory concern) route has been built up. Using a redundant rack, a trial was carried out to assess the technical and economic feasibility of the decontamination/free release route. An electrochemical process was employed. The trial successfully demonstrated technical feasibility, and an economic assessment concluded that the route can be justified financially. Therefore a decision was taken to dispose of all the racks by decontamination and free release. (Author)

  11. Development of decontamination technology for the decommissioned Bohunice A-1 nuclear power plant

    International Nuclear Information System (INIS)

    Krejci, F.; Majersky, D.; Solcanyi, M.; Sekely, S.; Kucharik, D.

    1991-01-01

    The main results of investigation into the decontamination technology for the equipment and buildings of the decommissioned A-1 nuclear power plant, achieved by the Nuclear Power Plants Research Institute in Trnava over the 1988-1990 period, are summarized. Mobile decontamination and recirculation equipment has been developed for pre-disassembling decontamination. A solution containing formic acid (19 g/l), EDTA-Na 4 (6 g/l) and thiourea (0.5 g/l) was used for decontamination of low-alloy steels; for materials from the steam generators and turbo-compressors, the decontamination factor (DF) of this solution was 30 to 150 per decontamination cycle. For high-alloy steels, a two-stage process comprising the use of an oxidation solution and a reduction solution appeared suitable. The oxidation solution contained potassium permanganate (0.6 g/l) and nitric acid (0.4 g/l), whereas the reduction solution, viz. Citrox 21, contained citric acid (0.5 g/l), oxalic acid (1.0 g/l) and EDTA-NA 4 (2.5 g/l). The DF is 10 to 50 in one oxidation-reduction cycle and 50-100 in two cycles. For the post-disassembling chemical decontamination, the contaminated material was cut into pieces 70 to 80 cm long, freed from grease and decontaminated chemically by submerging in the solution while applying treatment by ultrasound. A technology of electrochemical decontamination has also been developed. It appeared particularly suitable for structural materials of the primary coolant circuit comprising austenitic stainless steels and low-alloy steels after pre-disassembling chemical decontamination with remainders of the corrosion layer, and for structural materials of the secondary coolant circuit after chemical post-disassembling decontamination. Research in the field of decontamination of the building parts and of the outer surfaces of the structural materials concentrated mainly on the use of decontamination foams. Foaming solutions have been developed for the decontamination of PESL floors and

  12. Decontamination of CANDU primary coolant system

    International Nuclear Information System (INIS)

    Pettit, P.J.

    1975-01-01

    Decontamination of radioactive systems is necessary to reduce personnel radiation exposures and also to reduce exposure during special work. Mechanical decontamination methods are sometimes useful, but most contaminated surfaces are inaccessible, so chemical decontamination often is preferred. The A-P Citrox method will remove most contaminants from CANDU systems, but is costly and long, damages components, and produces large quantities of radioactive liquid waste. The Redox cycling process is fast and inexpensive, produces only solid wastes, but removes small quantities of deposit from Monel only. The CAN-DECON process removes deposits from most materials including fuel cladding and has many other advantages. (author)

  13. Development of chemical decontamination process with sulfuric acid-cerium (IV) for decommissioning

    International Nuclear Information System (INIS)

    Suwa, Takeshi; Kuribayashi, Nobuhide; Tachikawa, Enzo

    1988-01-01

    The electrolytic regeneration of Ce 4+ from Ce 3+ , which is required to achieve a high decontamination factor (DF) in this process, has been investigated. A calculating model was derived for the regenerating current required during the decontamination as a function of dissolution rate of crud, corrosion rate (R c ), current efficiency (η e ) and characteristics of decontamination loop. From the above calculation, it was found that the current was mainly governed by R c and η e . A condition to obtain a high DF at low R c and high η e has been found experimentally by use of a mixture of Ce 3+ at the ratio of Ce 4+ /Ce 3+ = 0.1 ∼ 0.2. The desired values to be η e ≥ 80 % at above 50 A/m 2 was obtained under the flow rate above 300 cm/min and Ce 3+ concentration above 10 x 10 -3 M at 60 deg C using the dual-cylindrical type cell. The current efficiency was also investigated with cells of various geometries. The present decontamination process has been proposed as a system decontamination process, which is essentially a single-step decontamination process for Cr-rich oxides. (author)

  14. Formerly utilized MED/AEC sites Remedial Action Program. Report of the decontamination of Jones Chemical Laboratory, Ryerson Physical Laboratory, and Eckhart Hall, the University of Chicago, Chicago, Illinois

    Energy Technology Data Exchange (ETDEWEB)

    Wynuveen, R.A.; Smith, W.H.; Sholeen, C.M.; Flynn, K.F.

    1984-08-01

    The US Department of Energy (DOE) has implemented a program to decontaminate radioactively contaminated sites that were formerly utilized by the Manhattan Engineer District (MED) and/or the Atomic Energy Commission (AEC) for activities that included handling of radioactive material. This program is referred to as the ''Formerly Utilized Sites Remedial Action Program'' (FUSRAP). Among these sites are Jones Chemical Laboratory, Ryerson Physical Laboratory, Kent Chemical Laboratory, and Eckhart Hall of The University of Chicago, Chicago, Illinois. Since 1977, the University of Chicago decontaminated Kent Chemical Laboratory as part of a facilities renovation program. All areas of Eckhart Hall, Ryerson Physical Laboratory, and Jones Chemical Laboratory that had been identified as contaminated in excess of current guidelines in the 1976-1977 surveys were decontaminated to levels where no contamination could be detected relative to natural backgrounds. All areas that required defacing to achieve this goal were restored to their original condition. The radiological evaluation of the sewer system, based primarily on the radiochemical analyses of sludge and water samples, indicated that the entire sewer system is potentially contaminated. While this evaluation was defined as part of this project, the decontamination of the sewer system was not included in the purview of this effort. The documentation included in this report substantiates the judgment that all contaminated areas identified in the earlier reports in the three structures included in the decontamination effort (Eckhart Hall, Ryerson Physical Laboratory, and Jones Chemical Laboratory) were cleaned to levels commensurate with release for unrestricted use.

  15. Formerly utilized MED/AEC sites Remedial Action Program. Report of the decontamination of Jones Chemical Laboratory, Ryerson Physical Laboratory, and Eckhart Hall, the University of Chicago, Chicago, Illinois

    International Nuclear Information System (INIS)

    Wynuveen, R.A.; Smith, W.H.; Sholeen, C.M.; Flynn, K.F.

    1984-08-01

    The US Department of Energy (DOE) has implemented a program to decontaminate radioactively contaminated sites that were formerly utilized by the Manhattan Engineer District (MED) and/or the Atomic Energy Commission (AEC) for activities that included handling of radioactive material. This program is referred to as the ''Formerly Utilized Sites Remedial Action Program'' (FUSRAP). Among these sites are Jones Chemical Laboratory, Ryerson Physical Laboratory, Kent Chemical Laboratory, and Eckhart Hall of The University of Chicago, Chicago, Illinois. Since 1977, the University of Chicago decontaminated Kent Chemical Laboratory as part of a facilities renovation program. All areas of Eckhart Hall, Ryerson Physical Laboratory, and Jones Chemical Laboratory that had been identified as contaminated in excess of current guidelines in the 1976-1977 surveys were decontaminated to levels where no contamination could be detected relative to natural backgrounds. All areas that required defacing to achieve this goal were restored to their original condition. The radiological evaluation of the sewer system, based primarily on the radiochemical analyses of sludge and water samples, indicated that the entire sewer system is potentially contaminated. While this evaluation was defined as part of this project, the decontamination of the sewer system was not included in the purview of this effort. The documentation included in this report substantiates the judgment that all contaminated areas identified in the earlier reports in the three structures included in the decontamination effort (Eckhart Hall, Ryerson Physical Laboratory, and Jones Chemical Laboratory) were cleaned to levels commensurate with release for unrestricted use

  16. Development of acidic processes for decontaminating LMFBR components

    Energy Technology Data Exchange (ETDEWEB)

    Hill, E F [Rockwell International, Atomics International Division, Canoga Park (United States); Colburn, R P; Lutton, J M; Maffei, H P [Hanford Engineering Development Laboratory, Richland (United States)

    1978-08-01

    The objective of the DOE decontamination program is to develop a well characterized chemical decontamination process for application to LMFBR primary system components that subsequently permits contact maintenance and allows requalification of the components for reuse in reactors. The paper describes the subtasks of deposit characterization, development of requalification and process acceptance criteria, development of process evaluation techniques and studies which led to a new acidic process for decontaminating 304 stainless steel hot leg components.

  17. Development of acidic processes for decontaminating LMFBR components

    International Nuclear Information System (INIS)

    Hill, E.F.; Colburn, R.P.; Lutton, J.M.; Maffei, H.P.

    1978-01-01

    The objective of the DOE decontamination program is to develop a well characterized chemical decontamination process for application to LMFBR primary system components that subsequently permits contact maintenance and allows requalification of the components for reuse in reactors. The paper describes the subtasks of deposit characterization, development of requalification and process acceptance criteria, development of process evaluation techniques and studies which led to a new acidic process for decontaminating 304 stainless steel hot leg components

  18. Foam process for application of decontamination agents

    International Nuclear Information System (INIS)

    Harris, J.M.; Miller, J.R.; Frazier, R.S.; Walter, J.H.

    1982-01-01

    This paper presents the results and observations of a study performed by the authors to parametrically evaluate the performance characteristics of a foam process for application of decontamination agents. The initial tests were established to assess foam quality. Subsequent tests determined the ability of the foam as a carrier of chemical systems, and established system operating parameters. The technique was then applied in an actual decontamination task to verify effectiveness of these established parameters and to determine decontamination reduction factors. 4 figures, 5 tables

  19. Electrochemical decontamination system for actinide processing gloveboxes

    International Nuclear Information System (INIS)

    Wedman, D.E.; Lugo, J.L.; Ford, D.K.; Nelson, T.O.; Trujillo, V.L.; Martinez, H.E.

    1998-03-01

    An electrolytic decontamination technology has been developed and successfully demonstrated at Los Alamos National Laboratory (LANL) for the decontamination of actinide processing gloveboxes. The technique decontaminates the interior surfaces of stainless steel gloveboxes utilizing a process similar to electropolishing. The decontamination device is compact and transportable allowing it to be placed entirely within the glovebox line. In this way, decontamination does not require the operator to wear any additional personal protective equipment and there is no need for additional air handling or containment systems. Decontamination prior to glovebox decommissioning reduces the potential for worker exposure and environmental releases during the decommissioning, transport, and size reduction procedures which follow. The goal of this effort is to reduce contamination levels of alpha emitting nuclides for a resultant reduction in waste level category from High Level Transuranic (TRU) to low Specific Activity (LSA, less than or equal 100 nCi/g). This reduction in category results in a 95% reduction in disposal and disposition costs for the decontaminated gloveboxes. The resulting contamination levels following decontamination by this method are generally five orders of magnitude below the LSA specification. Additionally, the sodium sulfate based electrolyte utilized in the process is fully recyclable which results in the minimum of secondary waste. The process bas been implemented on seven gloveboxes within LANL's Plutonium Facility at Technical Area 55. Of these gloveboxes, two have been discarded as low level waste items and the remaining five have been reused

  20. A Polyoxoniobate-Polyoxovanadate Double-Anion Catalyst for Simultaneous Oxidative and Hydrolytic Decontamination of Chemical Warfare Agent Simulants.

    Science.gov (United States)

    Dong, Jing; Hu, Jufang; Chi, Yingnan; Lin, Zhengguo; Zou, Bo; Yang, Song; Hill, Craig L; Hu, Changwen

    2017-04-10

    A novel double-anion complex, H 13 [(CH 3 ) 4 N] 12 [PNb 12 O 40 (V V O) 2 ⋅(V IV 4 O 12 ) 2 ]⋅22 H 2 O (1), based on bicapped polyoxoniobate and tetranuclear polyoxovanadate was synthesized, characterized by routine techniques and used in the catalytic decontamination of chemical warfare agents. Under mild conditions, 1 catalyzes both hydrolysis of the nerve agent simulant, diethyl cyanophosphonate (DECP) and selective oxidation of the sulfur mustard simulant, 2-chloroethyl ethyl sulfide (CEES). In the oxidative decontamination system 100 % CEES was transformed selectively to nontoxic 2-chloroethyl ethyl sulfoxide and vinyl ethyl sulfoxide using nearly stoichiometric 3 % aqueous H 2 O 2 with a turnover frequency (TOF) of 16 000 h -1 . Importantly, the catalytic activity is maintained even after ten recycles and CEES is completely decontaminated in 3 mins without formation of the highly toxic sulfone by-product. A three-step oxidative mechanism is proposed. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Comparison of dilute chemical decontaminations of RAPS-2 full primary heat transport system

    International Nuclear Information System (INIS)

    Bhat, H.R.

    2000-01-01

    First ever attempt to decontaminate a full primary system of an Indian PHWR was carried out at Rajasthan Atomic Power Station Unit -2 (RAPS-2) in August 1992. The decontamination factors obtained were moderate. The second attempt to decontaminate the same system was made in February 1996 with a different formulation. The decontamination factors obtained were lesser than the earlier attempt. The details of the two campaigns and their relative merits and demerits are discussed. Some more studies are required to be done before further implementation of the picolonic acid/ascorbic acid formulation. The 1992 attempt was with picolinic acid and ascorbic acid whereas the 1996 attempt was with EDTA + citric acid + ascorbic Acid (EAC ) formulation. A number of lessons were learnt from the first campaign and the improvements were applied during the subsequent decontamination campaigns at Madras Atomic Power station. The total iron removed and various radio nuclides removed are also detailed in the paper. Picolonic acid and ascorbic acid is a better formulation for decontamination of full PHT systems of Indian PHWRs. Use of EAC formulation generates a lot of crud which settles in narrow clearances. Picolonic Acid/Ascorbic Acid formulation does not generate any crud. Decontamination using a single cycle of the picolonic acid/ascorbic acid formulation is more effective than the decontamination using three cycles of EAC formulation. (author)

  2. Low corrosive chemical decontamination method using pH control. 1. Basic system

    International Nuclear Information System (INIS)

    Nagase, Makoto; Ishida, Kazushige; Uetake, Naohito; Anazawa, Kazumi; Nakamura, Fumito; Yoshikawa, Hiroo; Tamagawa, Tadashi; Furukawa, Kiyoharu

    2001-01-01

    A new low corrosive decontamination method was developed which uses both oxalic acid and hydrazine as the reducing agent and potassium permanganate as the oxidizing agent. Less corrosion of structural materials during the decontamination is realized by pH control of the reducing agent. The pH of 2.5, attained by adding hydrazine to oxalic acid, was the optimum pH for maintaining a high decontamination effect and lowering the corrosion at the same time. As this reducing agent can be decomposed into carbon dioxide, nitrogen and water by using a catalyst column with hydrogen peroxide, the amount of secondary radioactive waste is small. These good features were demonstrated through actual plant decontamination tasks. (author)

  3. A rapid and inexpensive bioassay to evaluate the decontamination of organophosphates.

    Science.gov (United States)

    Claborn, David M; Martin-Brown, Skylar A; Sagar, Sanjay Gupta; Durham, Paul

    2012-01-01

    An inexpensive and rapid bioassay using adult red flour beetles was developed for use in assessing the decontamination of environments containing organophosphates and related chemicals. A decontamination protocol was developed which demonstrated that 2 to 3 applications of 5% bleach solution were required to obtain nearly complete decontamination of malathion. The bioassay was also used to screen common household cleaners as potential decontaminating agents, but only 5% bleach was effective at improving survival of insects on steel plates treated with 25% malathion. A toxic degradation product (malaoxon) was detected using gas chromatography/mass spectrophotometry; this toxin affected the decontamination efficacy and resulted in continued toxicity to the beetles until subsequent decontaminations. The bioassay provides evidence to support the use of red flour beetles as a sensitive, less expensive method for determining safety levels of environments contaminated with malathion and other toxins, and may have application in the study of chemical warfare agents.

  4. Decontamination and dismantlement of Plant 7 at Fernald

    International Nuclear Information System (INIS)

    Albertin, M.; Borgman, T.; Zebick, B.

    1994-01-01

    Decontamination and dismantlement (D ampersand D) tasks have been successfully completed on Plant 7 at the Fernald Environmental Management Project. The seven story facility was radiologically, chemically, and biologically contaminated. The work involved the D ampersand D work beginning with safe shutdown and gross decontamination, and ended with removal of the structural steel. A series of lessons learned were gained which include use of explosives, bidding tactics, safe shutdown, building decontamination and lockdown, use of seam climbers, etc

  5. Evaluation of a decontamination model

    International Nuclear Information System (INIS)

    Rippin, D.W.T.; Hanulik, J.; Schenker, E.; Ullrich, G.

    1981-02-01

    In the scale-up of a laboratory decontamination process difficulties arise due to the limited understanding of the mechanisms controlling the process. This paper contains some initial proposals which may contribute to the quantitative understanding of the chemical and physical factors which influence decontamination operations. General features required in a mathematical model to describe a fluid-solid reaction are discussed, and initial work is presented with a simple model which has had some success in describing the observed laboratory behaviour. (Auth.)

  6. Impact of decontamination on LWR radioactive waste treatment systems

    International Nuclear Information System (INIS)

    Hoenes, G.R.; Perrigo, L.D.; Divine, J.R.; Faust, L.G.

    1979-01-01

    Only at N-Reactor is there a means to accommodate radwaste produced during decontamination. The Dresden system is expected to be ready to accommodate such solutions by the summer of 1979. Solidification of the processed decontamination waste may be a significant problem. There is doubt that the materials in current radwaste treatment systems can handle chemicals from a concentrated process. The total storage volume, for concentrated decontamination, is not sufficient in existing radwaste treatment systems. Greater attention should be placed on designing reactors and radwaste treatment systems for decontamination. A means of handling waste material resulting from leaks in the primary system during the decontamination must be developed. On-site storage of solidified decontamination wastes may be a viable option, but license amendments will be necessary

  7. Initial decontamination of the equipment decontamination room at the West Valley Demonstration Project. Topical report, September 1983-May 1985

    International Nuclear Information System (INIS)

    Meigs, R.A.

    1985-12-01

    The purpose of this report is to document the initial decontamination of the Equipment Decontamination Room (EDR). The effort spanned a two-year period and included packaging and removal of waste; grinding away contaminated concrete floors; pump-out and spraydown of an equipment soaking pit; washing and painting of walls, equipment, and floors; refurbishment of utilities and various pieces of equipment; and load tests of EDR and Chemical Process Cell (CPC) cranes. After decontamination, the EDR was converted into a waste handling area for the decommissioning of the CPC

  8. Precipitation process for supernate decontamination

    International Nuclear Information System (INIS)

    Lee, L.M.; Kilpatrick, L.L.

    1982-11-01

    A precipitation and adsorption process has been developed to remove cesium, strontium, and plutonium from water-soluble, high-level radioactive waste. An existing waste tank serves as the reaction vessel and the process begins with the addition of a solution of sodium tetraphenylborate and a slurry of sodium titanate to the contained waste salt solution. Sodium tetraphenylborate precipitates the cesium and sodium titanate adsorbs the strontium and plutonium. The precipitate/adsorbate is then separated from the decontaminated salt solution by crossflow filtration. This new process offers significant capital savings over an earlier ion exchange process for salt decontamination. Chemical and small-scale engineering studies with actual waste are reported. The effect of many variables on the decontamination factors and filter performance are defined

  9. Chemical decontamination for decommissioning - the Jose Cabrera (Zorita) NPP

    International Nuclear Information System (INIS)

    Madrid Garcia, F.; Holgado, A.; Pomar, C.; Gammon, Th.; Bradbury, D.

    2008-01-01

    The Jose Cabrera (Zorita) NPP is located in the Guadalajara province of Spain approximately 66 km northeast of Madrid. It is a single loop Westinghouse Pressurized Water Reactor (PWR) design cooled by the waters of the River Tajo. The plant was synchronized to the grid in 1968 and was permanently shutdown on April 30, 2006. UNION FENOSA Generacion has been the owner and operator of the plant and will hand over decommissioning activities to Empresa Nacional de Residuous Radiactivos, S.A. (ENRESA) in approximately two years. During the fall and winter of 2006, Westinghouse Electric Company performed a Full System Decontamination (FSD) in preparation for decommissioning activities. The FSD was performed on the Reactor Coolant System (RCS) including the Residual Heat Removal System (RHRS) and the Chemical Volume and Control System (CVCS). The FSD was performed to facilitate decommissioning activities by reducing general area dose rates and lowering contamination levels to reduce disposal costs. (authors)

  10. Planning guidance for nuclear-power-plant decontamination. [PWR; BWR

    Energy Technology Data Exchange (ETDEWEB)

    Munson, L.F.; Divine, J.R.; Martin, J.B.

    1983-06-01

    Direct and indirect costs of decontamination are considered in the benefit-cost analysis. A generic form of the benefit-cost ratio is evaluated in monetary and nonmonetary terms, and values of dollar per man-rem are cited. Federal and state agencies that may have jurisiction over various aspects of decontamination and waste disposal activities are identified. Methods of decontamination, their general effectiveness, and the advantages and disadvantages of each are outlined. Dilute or concentrated chemical solutions are usually used in-situ to dissolve the contamination layer and a thin layer of the underlying substrate. Electrochemical techniques are generally limited to components but show high decontamination effectiveness with uniform corrosion. Mechanical agents are particularly appropriate for certain out-of-system surfaces and disassembled parts. These processes are catagorized and specific concerns are discussed. The treatment, storage, and disposal or discharge or discharge of liquid, gaseous, and solid wastes generated during the decontamination process are discussed. Radioactive and other hazardous chemical wastes are considered. The monitoring, treatment, and control of radioactive and nonradioactive effluents, from both routine operations and possible accidents, are discussed. Protecting the health and safety of personnel onsite during decontamination is of prime importance and should be considered in each facet of the decontamination process. The radiation protection philosophy of reducing exposure to levels as low as reasonably achievable should be stressed. These issues are discussed.

  11. Effect of decontamination on nuclear power plant primary circuit materials

    International Nuclear Information System (INIS)

    Brezina, M.; Kupca, L.

    1991-01-01

    The effect of repeated decontamination on the properties of structural materials of the WWER-440 primary coolant circuit was examined. Three kinds of specimens of 08Kh18Ni10T steel were used for radioactivity-free laboratory experiments; they included material obtained from assembly additions to the V-2 nuclear power plant primary piping, and a sheet of the CSN 17247 steel. Various chemical, electrochemical and semi-dry electrochemical decontamination procedures were tested. Chemical decontamination was based on the conventional AP(20/5)-CITROX(20/20) procedure and its variants; NP-CITROX type procedures with various compositions were also employed. Solutions based on oxalic acid were tested for the electrochemical and semi-dry electrochemical decontamination. The results of measurements of mass losses of the surfaces, of changes in the corrosion resistance and in the mechanical properties of the materials due to repeated decontamination are summarized. (Z.S.). 12 figs., 1 tab., 8 refs

  12. Evaluation of Veriox as a Skin Decontamination Product after Dermal Exposure to the Nerve Agent VX

    Science.gov (United States)

    2016-09-01

    was to determine whether Veriox® had efficacy as a decontamination product (DC) after skin exposure to the chemical warfare agent VX. This study...countermeasure, decontamination , RSDL, VX, nerve agent, cutaneous exposure, chemical warfare agent 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT...invested considerable resources in developing detectors, protective garments, and products to remove and/or decontaminate chemical agent exposure on

  13. Decontamination System Development of Radioative Activated Carbon using Micro-bubbles

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Jong seon; Kim, Wi soo [NESS, Daejeon (Korea, Republic of); Han, Byoung sub. [Enesys Co., Daejeon (Korea, Republic of)

    2016-10-15

    This study was aimed to develop a decontamination system by applying such technical characteristics that minimizes a generation of secondary wastes while decontaminating radiation wastes. The radioactive activated carbon is removed from the end-of-life air cleaning filter in replacement or decommission of nuclear power plant or nuclear facility. By removing radioactive activated carbon, the filter would be classified as a low radioactive contaminant. And thus the amount of radioactive wastes and the treatment cost would be decreased. We are in development of the activated carbon cleaning technique by utilizing micro-bubbles, which improve efficiency and minimize damage of activated carbon. The purpose of using micro-bubbles is to decontamination carbon micropore, which is difficult to access, by principle of cavitation phenomenon generated in collapse of micro-bubbles. In this study, we introduced the micro-bubble decontamination system developed to decontaminate activated carbon. For further researches, we will determine carbon weight change and the decontamination rate under the experimental conditions such as temperature and pH.

  14. Decontamination System Development of Radioative Activated Carbon using Micro-bubbles

    International Nuclear Information System (INIS)

    Jeon, Jong seon; Kim, Wi soo; Han, Byoung sub.

    2016-01-01

    This study was aimed to develop a decontamination system by applying such technical characteristics that minimizes a generation of secondary wastes while decontaminating radiation wastes. The radioactive activated carbon is removed from the end-of-life air cleaning filter in replacement or decommission of nuclear power plant or nuclear facility. By removing radioactive activated carbon, the filter would be classified as a low radioactive contaminant. And thus the amount of radioactive wastes and the treatment cost would be decreased. We are in development of the activated carbon cleaning technique by utilizing micro-bubbles, which improve efficiency and minimize damage of activated carbon. The purpose of using micro-bubbles is to decontamination carbon micropore, which is difficult to access, by principle of cavitation phenomenon generated in collapse of micro-bubbles. In this study, we introduced the micro-bubble decontamination system developed to decontaminate activated carbon. For further researches, we will determine carbon weight change and the decontamination rate under the experimental conditions such as temperature and pH

  15. Decomposition Technology Development of Organic Component in a Decontamination Waste Solution

    International Nuclear Information System (INIS)

    Jung, Chong Hun; Oh, W. Z.; Won, H. J.; Choi, W. K.; Kim, G. N.; Moon, J. K.

    2007-11-01

    Through the project of 'Decomposition Technology Development of Organic Component in a Decontamination Waste Solution', the followings were studied. 1. Investigation of decontamination characteristics of chemical decontamination process 2. Analysis of COD, ferrous ion concentration, hydrogen peroxide concentration 3. Decomposition tests of hardly decomposable organic compounds 4. Improvement of organic acid decomposition process by ultrasonic wave and UV light 5. Optimization of decomposition process using a surrogate decontamination waste solution

  16. Intervention and decontamination of hardware contaminated by tritium

    International Nuclear Information System (INIS)

    Cerre, Pierre; Mestre, Emile

    1964-10-01

    This report first describes the intervention process for teams intervening, either in case of accident or to modify or repair installations in which tritium is handled, i.e. in both cases in a contaminated atmosphere. Three main aspects are addressed: how to prepare and insulate the work place from the rest of the installation, how to protect the intervening personnel, and how to perform decontamination. The authors then present the various available decontamination techniques: decontamination bath at different temperatures and use of different chemical solutions at different temperatures, the degassing technique (temperature increase and vacuum, temperature hold during 30 to 45 minutes, return to atmospheric pressure), and mercury-based decontamination

  17. Evaluation of three different decontamination techniques on biofilm formation, and on physical and chemical properties of resin composites.

    Science.gov (United States)

    André, Carolina Bosso; Dos Santos, Andressa; Pfeifer, Carmem Silvia; Giannini, Marcelo; Girotto, Emerson Marcelo; Ferracane, Jack Liborio

    2018-04-01

    This study evaluated three different sterilization/disinfection techniques for resin composites on bacterial growth and surface modification after decontamination. Two resin composites were sterilized/disinfected with three different techniques: UV light, 1% chloramine T, and 70% ethanol. Four different times were used for each technique to determine the shortest time that the solution or UV light was effective. The influence of sterilization/disinfection technique on bacterial growth was evaluated by analyzing the metabolic activity, using the AlamarBlue™ assay, bacterial viability, and SEM images from biofilms of Streptococcus mutans. The surface change, after the process, was analyzed with ATR/FTIR and SEM images. The solutions used for decontamination (1% chloramine-T and 70% ethanol) were analyzed with 1 H-NMR to identify any resin compounds leached during the process. One minute of decontamination was efficient for all three methods tested. Chloramine-T increased the surface porosity on resin composites, no changes were observed for UV light and 70% ethanol, however, 1 H-NMR identified leached monomers only when 70% ethanol was used. No chemical change of the materials was found under ATR/FTIR analyses after the decontamination process. Chloramine-T, with no previous wash, increased the bacterial viability for both resin composites and increased the bacterial metabolism for the resin composite without fluoride. UV light had no interference on the resin composites properties tested using 1 min of exposure compared to the other decontamination methods. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 945-953, 2018. © 2017 Wiley Periodicals, Inc.

  18. Electrochemical decontamination of metallic surfaces by means of a movable electrode

    International Nuclear Information System (INIS)

    Mihai, F.; Nicu, M.; Cazan, L.; Turcanu, C.

    1998-01-01

    Electrochemical decontamination can be considered to be a decontamination assisted by an electrochemical field. The method is applied to the metallic surface decontamination for contaminants of any physico-chemical nature. The physico-chemical phenomenon that is the basis for the electrochemical methods is the anodic layer dissolution. By dissolution of the superficial layer any radioactive contaminant on the surface or entrapped within the surface oxide is eliminated. Electrochemical decontamination, also known as electropolishing, involves the use of the object to be cleaned as an anode in an electrochemical cell. The passage of current results in anodic dissolution of the surface material. Generally, there are many methods of application for electropolishing. The most common method is immersing the object to be decontaminated in a tank filled with a suitable electrolyte. The electrochemical method with movable electrode involves the use of 'in situ' mobile devices that are able to electropolish punctual surfaces in places difficult to access. The advantages are the simplicity of the setup, short times of application and reduced waste volumes. Phosphoric and sulphuric acid mixture is used as the electrolyte in electropolishing because of its stability, safety and applicability to a variety of alloy systems. The method was applied to decontaminate carbon steel, aluminium and copper. Used contaminants are mixtures of 60 Co and 134 Cs; 60 Co and 65 Zn; 60 Co, 65 Zn and 134 Cs. After preparation, the samples were kept in laboratory conditions about one month, to simulate real conditions and to let the chemical reactions between contaminant and sample material constitution to complete. To calculate decontamination factor characteristic for each studied decontamination method the following radiometric measurements are necessary: - activity measurement after radioisotope solution contamination representing initial activity Λ in ; - activity measurement after

  19. Decontamination Technology Development for Nuclear Research Facilities

    International Nuclear Information System (INIS)

    Oh, Won Zin; Jung, Chong Hun; Choi, Wang Kyu; Won, Hui Jun; Kim, Gye Nam

    2004-02-01

    Technology development of surface decontamination in the uranium conversion facility before decommissioning, technology development of component decontamination in the uranium conversion facility after decommissioning, uranium sludge treatment technology development, radioactive waste soil decontamination technology development at the aim of the temporary storage soil of KAERI, Optimum fixation methodology derivation on the soil and uranium waste, and safety assessment methodology development of self disposal of the soil and uranium waste after decontamination have been performed in this study. The unique decontamination technology applicable to the component of the nuclear facility at room temperature was developed. Low concentration chemical decontamination technology which is very powerful so as to decrease the radioactivity of specimen surface under the self disposal level was developed. The component decontamination technology applicable to the nuclear facility after decommissioning by neutral salt electro-polishing was also developed. The volume of the sludge waste could be decreased over 80% by the sludge waste separation method by water. The electrosorption method on selective removal of U(VI) to 1 ppm of unrestricted release level using the uranium-containing lagoon sludge waste was tested and identified. Soil decontamination process and equipment which can reduce the soil volume over 90% were developed. A pilot size of soil decontamination equipment which will be used to development of real scale soil decontamination equipment was designed, fabricated and demonstrated. Optimized fixation methodology on soil and uranium sludge was derived from tests and evaluation of the results. Safety scenario and safety evaluation model were development on soil and uranium sludge aiming at self disposal after decontamination

  20. Decomposition Technology Development of Organic Component in a Decontamination Waste Solution

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Chong Hun; Oh, W. Z.; Won, H. J.; Choi, W. K.; Kim, G. N.; Moon, J. K

    2007-11-15

    Through the project of 'Decomposition Technology Development of Organic Component in a Decontamination Waste Solution', the followings were studied. 1. Investigation of decontamination characteristics of chemical decontamination process 2. Analysis of COD, ferrous ion concentration, hydrogen peroxide concentration 3. Decomposition tests of hardly decomposable organic compounds 4. Improvement of organic acid decomposition process by ultrasonic wave and UV light 5. Optimization of decomposition process using a surrogate decontamination waste solution.

  1. Chemical decontamination of the residual heat removal system (RHRS) of Flamanville 1

    International Nuclear Information System (INIS)

    Steinkuhler, Claude; Coomans, Reginald; Koen, Lenie

    2007-01-01

    The purpose of the decontamination of the RHRS at Flamanville 1 was the reduction of the general dosimetry and the elimination of hot spots. This was done to allow the maintenance on the RHRS equipment. The main challenge of this project was the execution of a complicated operation on the critical path of a shutdown. The redox attack of the oxides at the surface of the circuit in Flamanville, was performed by an EDF qualified process of the EMMAC family. The functions required by the decontamination system were very diverse and therefore an existing decontamination loop, which was previously developed for the decontamination of small system volumes, was re-developed and adapted for bigger circuits. Due to different reasons, an important delay on the planning happened. Therefore, only one cycle EMMAg was performed, totalling 2 hours of decontamination. Despite this, a DRRF (dose rate reduction factor) of 3,7 average was reached. The re-designed equipment and a shortened process were validated during this project. An acceptable DRRF was reached with no delay on the critical path. The capability of maintenance on the RHRS equipment is recovered with a gain of factor 5 on dosimetry. (authors)

  2. Experience in decontamination of the equipment of NPP's with the WWER-440 reactors

    International Nuclear Information System (INIS)

    Balaban-Irmenin, Yu.V.

    1981-01-01

    Different methods of decontamination at NPPs are briefly characterized. Decontamination of the removable part of the main circulation pump (MCP) of the WWER-440 reactor is considered as an example of removable equipment decontamination. A design of the decontamination bath of the removable MCP elements and the applied chemical agents are described. A decontamination flowsheet of the Novovoronezh NPP steam generator (SG) is considered as an example of the autonomic decontamination system. The SG decontamination modes, principal flowsheets of a hydromonitor, steam-ejection sprayer and steam-emulsion device are described [ru

  3. Available decontamination and decommissioning capabilities at the Savannah River Technology Center

    International Nuclear Information System (INIS)

    Polizzi, L.M.; Norkus, J.K.; Paik, I.K.; Wooten, L.A.

    1992-01-01

    The Safety Analysis and Engineering Services Group has performed a survey of the Savannah River Technology Center (SRTC) technical capabilities, skills, and experience in Decontamination and Decommissioning (D ampersand D) activities. The goal of this survey is to enhance the integration of the SRTC capabilities with the technical needs of the Environmental Restoration Department D ampersand D program and the DOE Office of Technology Development through the Integrated Demonstration Program. This survey has identified technical capabilities, skills, and experience in the following D ampersand D areas: Characterization, Decontamination, Dismantlement, Material Disposal, Remote Systems, and support on Safety Technology for D ampersand D. This review demonstrates the depth and wealth of technical capability resident in the SRTC in relation to these activities, and the unique qualifications of the SRTC to supply technical support in the area of DOE facility D ampersand D. Additional details on specific technologies and applications to D ampersand D will be made available on request

  4. Investigation of electro-kinetic methods for soil decontamination

    International Nuclear Information System (INIS)

    Shabanova, A.N.

    2000-01-01

    The choices of effective methods for ecological system decontamination, their perfection and introduction into practical use have been actual tasks for the Ural region. The objective of this work has been to study the potentials of electrical kinetics method of ISOTRON Corporation (US) for decontamination of the Urals soils. Results obtained have shown the method proposed to be usable for decontaminating some types of soils from strontium and plutonium; it is low effective for decontamination in the area of South-Urals radioactive plume. Thus, a low effectiveness can be expected in podsolic and leached laterite characterized by a high content of loamy sand and sandy soils, as well as for sobby-podsolic ones. The method can be promising for decontamination of soils and wastes from chemical contaminants, such as Zn, Ni, Cu, Pb, Hg, and others. Important advantages of this method compared to others have been its simplicity, small amount of wastes, and feasibility of decontamination in areas difficult to access. (authors)

  5. Development of haemostatic decontaminants for the treatment of wounds contaminated with chemical warfare agents. 1: evaluation of in vitro clotting efficacy in the presence of certain contaminants.

    Science.gov (United States)

    Hall, Charlotte A; Lydon, Helen L; Dalton, Christopher H; Chipman, J K; Graham, John S; Chilcott, Robert P

    2015-05-01

    The treatment of penetrating, haemorrhaging injuries sustained within a hazardous environment may be complicated by contamination with toxic chemicals. There are currently no specific medical countermeasures for such injuries. Haemostats with an absorbent mechanism of action have the potential to simultaneously stop bleeding and decontaminate wounds. However, a primary requirement of a 'haemostatic decontaminant' is the retention of clotting function in the presence of chemical contaminants. Thus, the aim of this study was to investigate the haemostatic efficacy of seven commercially available haemostats in the presence of toxic chemicals (soman, VX, sulphur mustard, petrol, aviation fuel and motor oil). Clot viscosity was assessed ex vivo using thrombelastography following treatment of pig blood with: (i) toxic chemical; (ii) haemostat; or (iii) haemostat in combination with toxic chemical. Several contaminants (VX, petrol and GD) were found to be pro-haemostatic and none had an adverse effect on the rate with which the test products attained haemostasis. However, the total clot strength for blood treated with certain haemostats in the presence of sulphur mustard, soman and petrol was significantly decreased. Three test products failed to demonstrate haemostatic function in this ex vivo (thrombelastography) model; this was tentatively ascribed to the products achieving haemostasis through a tamponade mechanism of action, which can only be replicated using in vivo models. Overall, this study has identified a number of commercial products that may have potential as haemostatic decontaminants and warrant further investigation to establish their decontaminant efficacy. Copyright © 2014 John Wiley & Sons, Ltd.

  6. Effect of decontamination on aging processes and considerations for life extension

    International Nuclear Information System (INIS)

    Diercks, D.R.

    1987-10-01

    The basis for a recently initiated program on the chemical decontamination of nuclear reactor components and the possible impact of decontamination on extended-life service is described. The incentives for extending plant life beyond the present 40-year limit are discussed, and the possible aging degradation processes that may be accentuated in extended-life service are described. Chemical decontamination processes for nuclear plant primary systems are summarized with respect to their corrosive effects on structural alloys, particularly those in the aged condition. Available experience with chemical cleaning processes for the secondary side of PWR steam generators is also briefly considered. Overall, no severe materials corrosion problems have been found that would preclude the use of these chemical processes, but concerns have been raised in several areas, particularly with respect to corrosion-related problems that may develop during extended service

  7. Radiological experience on decontamination of moderator and associated system at NAPS-1

    International Nuclear Information System (INIS)

    Yadav, C.L.R.; Mitra, S.R.; Pawar, S.K.; Lal Chand

    2000-01-01

    Narora Atomic Power Station, the first of Indian standardized Pressurized Heavy Water Reactor, is faced with a problem of 60 Co contamination in moderator and its associated system. This contamination has resulted in increase of collective dose contribution. As a part of ALARA campaign in NAPS it was decided to decontaminate the moderator and associated systems and also incorporate modification which will further control the 60 Co contamination. As a part of decontamination program several experiments to determine the effectiveness of the chemical formulation on SS and cupro-nickel surfaces were carried out on various moderator system equipment before finalizing the formulation for full scale decontamination of moderator system. This paper gives an overview of various modifications in system and decontamination efficiency of various chemical formulation which were used for decontamination of moderator system (excluding calandria) and associated equipment. (author)

  8. Studies on the process aspects related to chemical decontamination of chromium-containing alloys with redox processes

    International Nuclear Information System (INIS)

    Kumar, P.S.; Suresh, S.; Chandran, S.; Velmurugan, S.; Narasimhan, S.V.; Rajesh, P.

    2004-01-01

    Presence of chromium in the oxide layer makes oxidative pre-treatment with oxidizing agents such as potassium permanganate (KMnO 4 ) a must for the decontamination of stainless steels and other chromium containing alloys. The effectiveness of pre-treatment with oxidizing reagent varies with the conditions of treatment such as temperature, concentration and whether the medium is acidic or alkaline. A comparative study of the two acidic oxidizing agents, i.e., nitric acid-permanganate and permanganic acid was made. The dissolution behavior of copper and its oxide in permanganic acid was found to be comparable to that of chromium oxide. Citric acid and ascorbic acid were investigated as alternatives to oxalic acid for the reduction/decomposition of permanganate left over after the oxidizing pre-treatment step. It has been established that the reduction of chromate by citric acid is instantaneous only in presence of Mn 2+ ions. It has also been established that reduction of residual permanganate can be achieved with ascorbic acid and with minimum chemical requirement. The capabilities of nitrilotriacetic acid (NTA)-ascorbic acid mixture for the dissolution of hematite have been explored. This study would help to choose the suitable oxidizing agent, the reducing agent used for decomposition of permanganate and to optimize the concentration of reducing formulation so that the process of decontamination is achieved with a minimum requirement of chemicals. The generation of radioactive ion exchange resin as waste is therefore held at a minimum. Ion exchange studies with metal ion complexes of relevance to decontamination were carried out with a view to choose a suitable type of ion exchanger. It has been established that treatment of the ion exchange resin with brine solution can solve the problem of leaching out of non-ionic organics from the resin. (orig.)

  9. Considerations about house decontamination in Goiania: limits and consequences

    International Nuclear Information System (INIS)

    Silva, C.J. da; Delgado, J.U.; Luiz, M.T.B.; Cunha, P.G.; Barros, P.D. de

    1988-01-01

    We are considering some aspects related to the decontamination activities about 50 houses affected by Cs-137 in Goiania city. We described the way these contaminations occurred, the instruments used and the procedures. We also discuss the dose limits establised in the decontamination and the consequences resulting from this action. We call attention to the fact that not only the technical aspects in such activities bu also the psycho-social implications resulting from them are specially important. (author) [pt

  10. A dilute chemical decontaminant formulation containing gallic acid as a reductant

    International Nuclear Information System (INIS)

    Kishore, K.; Rajesh, P.; Kumbhar, A.G.

    2001-01-01

    Gallic acid (GA) was tried as a reductant in place of ascorbic acid in dilute chemical decontaminant (DCD) formulations. Dissolution of magnetite in GA based DCD formulations was studied at 50 C as well as 80 C. It was found to be a good substitute for ascorbic acid in EDTA/ascorbic acid/citric acid, i.e., EAC formulation. The efficiency of EDTA/GA/CA formulation was as good as that of EAC formulation. 2.8 was found to be the optimum pH for this formulation and dissolution decreased at lower as well as higher pHs. The ion exchange behaviour of GA is also appropriate for using it in a regenerating type of formulation. Being an aromatic compound, Gallic acid has inherent stability against radiation degradation. (orig.)

  11. Decontamination Technology Development for Nuclear Research Facilities

    International Nuclear Information System (INIS)

    Choi, W. K.; Jung, C. H.; Oh, W. Z.

    2007-06-01

    The originative CO 2 pellet blasting equipment was developed by improving additional components such as feed screw, idle roller and air-lock feeder to clear up the problems of freezing and discontinuity of blasting and by adopting pneumatically operated vacuum suction head and vacuum cup to prevent recontamination by collecting contaminant particulates simultaneously with the decontamination. The optimum decontamination process was established according to the kind of materials such as metal, concrete and plastic and the type of contaminants such as particulate, fixed chemical compound and oil. An excellent decontamination performances were verified by means of the lab-scale hot test with radioactive specimen and the technology demonstration in IMEF hot cell. The PFC dry decontamination equipment applicable to the surface contaminated with high radioactive particulate was developed. This equipment consists of the unit processes such as spray, collection, filtration and dry distillation designed originatively applicable to inside of dry hot cell. Through the demonstration of PFC spray decontamination process in IMEF hot cell, we secured on-site applicability and the decontamination efficiency more than 90 %. We investigated the characteristics of dismantled metal waste melting and the radionuclide(Co, Cs, U) distribution into ingot and slag by melting decontamination experiments using electric arc melter. We obtained the decontamination factors greater than 100 for Cs and of 10∼100 for uranium. The pilot scale(200 kg/batch) demonstration for melting decontamination was carried out successfully using high temperature melting facility at KAERI. The volume reduction factor of 1/7 and the economical feasibility of the melting decontamination were verified.

  12. Radioactive decontamination of equipment

    International Nuclear Information System (INIS)

    1982-03-01

    After a recall of some definitions relating to decontamination techniques and of the regulation into effect, the principles to be respected to arrange rationally work zones are quoted while insisting more particularly on the types of coatings which facilitate maintenance operations and the dismantling of these installations. Then, the processes and equipments to use in decontamination units for routine or particular operations are described; the list of recommended chemical products to decontaminate the equipment is given. The influence of these treatments on the state and the duration of life of equipments is studied, and some perfectible methods are quoted. In the appendix, are given: the limits of surface contamination accepted in the centers; a standard project which defines the criteria of admissible residual contamination in wastes considered as cold wastes; some remarks on the interest that certain special ventilation and air curtain devices for the protection of operators working on apparatus generating contaminated dusts [fr

  13. Concrete decontamination by Electro-Hydraulic Scabbling (EHS)

    International Nuclear Information System (INIS)

    1994-11-01

    EHS is being developed for decontaminating concrete structures from radionuclides, organic substances, and hazardous metals. EHS involves the generation of powerful shock waves and intense cavitation by a strong pulsed electric discharge in a water layer at the concrete surface; high impulse pressure results in stresses which crack and peel off a concrete layer of controllable thickness. Scabbling produces contaminated debris of relatively small volume which can be easily removed, leaving clean bulk concrete. Objective of Phase I was to prove the technical feasibility of EH for controlled scabbling and decontamination of concrete. Phase I is complete

  14. Concrete decontamination by Electro-Hydraulic Scabbling (EHS)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-11-01

    EHS is being developed for decontaminating concrete structures from radionuclides, organic substances, and hazardous metals. EHS involves the generation of powerful shock waves and intense cavitation by a strong pulsed electric discharge in a water layer at the concrete surface; high impulse pressure results in stresses which crack and peel off a concrete layer of controllable thickness. Scabbling produces contaminated debris of relatively small volume which can be easily removed, leaving clean bulk concrete. Objective of Phase I was to prove the technical feasibility of EH for controlled scabbling and decontamination of concrete. Phase I is complete.

  15. Tritium decontamination of machine components and walls

    International Nuclear Information System (INIS)

    Hircq, B.; Wong, K.Y.; Jalbert, R.A.; Shmayda, W.T.

    1991-01-01

    Tritium decontamination techniques for machine components and their application at tritium handling facilities are reviewed. These include commonly used methods such as vacuuming, purging, thermal desorption and isotopic exchange as well as less common methods such as chemical/electrochemical etching, plasma discharge cleaning, and destructive methods. Problems associated with tritium contamination of walls and use of protective coatings are reviewed. Tritium decontamination considerations at fusion facilities are discussed

  16. Bacterial decontamination using ambient pressure nonthermal discharges

    Energy Technology Data Exchange (ETDEWEB)

    Birmingham, J.G.; Hammerstrom, D.J.

    2000-02-01

    Atmospheric pressure nonthermal plasmas can efficiently deactivate bacteria in gases, liquids, and on surfaces, as well as can decompose hazardous chemicals. This paper focuses on the changes to bacterial spores and toxic biochemical compounds, such as mycotoxins, after their treatment in ambient pressure discharges. The ability of nonthermal plasmas to decompose toxic chemicals and deactivate hazardous biological materials has been applied to sterilizing medical instruments, ozonating water, and purifying air. In addition, the fast lysis of bacterial spores and other cells has led us to include plasma devices within pathogen detection instruments, where nucleic acids must be accessed. Decontaminating chemical and biological warfare materials from large, high value targets such as building surfaces, after a terrorist attack, are especially challenging. A large area plasma decontamination technology is described.

  17. Decontamination and decommissioning technology tree and the current status of the technologies

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Won Zin; Won, H.J.; Kim, G.N.; Lee, K.W.; Chol, W.K.; Jung, C.H.; Kim, C.J.; Kim, S.H.; Kwon, S.O.; Chung, C.M

    2001-03-01

    A technology tree diagram was developed on the basis of the necessary technologies applicable to the decontamination and decommissioning of nuclear facilities. The technology tree diagram is consist of 6 main areas such as characterization, decontamination, decommissioning and remote technology, radwaste management, site restoration, and decommissioning plan and engineering. Characterization is divided into 4 regions such as sampling and data collection, general characterization, chemical analysis and radiological analysis. Decontamination is also divided into 4 regions such as chemical decontamination, mechanical decontamination, the other decontamination technologies and new decontamination technologies. Decommissioning and remote technology area is divided into 4 regions such as cutting techniques, decommissioning technologies, new developing technologies and remote technologies. Radwaste management area is divided into 5 regions such as solid waste treatment, sludge treatment, liquid waste treatment, gas waste treatment and thermal treatment. Site restoration area is divided into 3 regions such as the evaluation of site contamination, soil decontamination and ground water decontamination. Finally, permission, decommissioning process, cost evaluation, quality assurance and the estimation of radionuclide inventory were mentioned in the decommissioning plan and engineering area. The estimated items for each technology are applicable domestic D and D facilities, D and D problem area and contamination/requirement, classification of D and D technology, similar technology, principle and overview of technology, status, science technology needs, implementation needs, reference and contact point.

  18. Decontamination and decommissioning technology tree and the current status of the technologies

    International Nuclear Information System (INIS)

    Oh, Won Zin; Won, H. J.; Kim, G. N.; Lee, K. W.; Chol, W. K.; Jung, C. H.; Kim, C. J.; Kim, S. H.; Kwon, S. O.; Chung, C. M.

    2001-03-01

    A technology tree diagram was developed on the basis of the necessary technologies applicable to the decontamination and decommissioning of nuclear facilities. The technology tree diagram is consist of 6 main areas such as characterization, decontamination, decommissioning and remote technology, radwaste management, site restoration, and decommissioning plan and engineering. Characterization is divided into 4 regions such as sampling and data collection, general characterization, chemical analysis and radiological analysis. Decontamination is also divided into 4 regions such as chemical decontamination, mechanical decontamination, the other decontamination technologies and new decontamination technologies. Decommissioning and remote technology area is divided into 4 regions such as cutting techniques, decommissioning technologies, new developing technologies and remote technologies. Radwaste management area is divided into 5 regions such as solid waste treatment, sludge treatment, liquid waste treatment, gas waste treatment and thermal treatment. Site restoration area is divided into 3 regions such as the evaluation of site contamination, soil decontamination and ground water decontamination. Finally, permission, decommissioning process, cost evaluation, quality assurance and the estimation of radionuclide inventory were mentioned in the decommissioning plan and engineering area. The estimated items for each technology are applicable domestic D and D facilities, D and D problem area and contamination/requirement, classification of D and D technology, similar technology, principle and overview of technology, status, science technology needs, implementation needs, reference and contact point

  19. A comparative evaluation of a dipicolinic acid based dilute chemical decontaminant formulation with respect to its efficacy for dissolution of iron oxides

    Energy Technology Data Exchange (ETDEWEB)

    Kamal Kishore; Dey, G.R.; Naik, D.B.; Moorthy, P.N. [Applied Chemistry Division, Bhabha Atomic Research Centre, Mumbai-400 085 (India)

    1998-12-31

    A dilute chemical decontamination formulation containing dipicolinic acid (2,6-pyridine dicarboxylic acid PDCA) and ascorbic acid (AA) has been found to be effective in dissolving magnetite, nickel ferrite and haemetite. Its main advantages arise because of (i) good solubility of the two constituents (ii) lack of absorption on the cation exchanger from acidic media during regenerative decontamination process (iii) stability to ionizing radiation and (iv) low corrosion rate for carbon steel. Dissolution rates of iron oxides in this formulation are as good as or better than in other well known formulations. (author)

  20. Efficacy of scalp hair decontamination following exposure to vapours of sulphur mustard simulants 2-chloroethyl ethyl sulphide and methyl salicylate.

    Science.gov (United States)

    Spiandore, Marie; Piram, Anne; Lacoste, Alexandre; Prevost, Philippe; Maloni, Pascal; Torre, Franck; Asia, Laurence; Josse, Denis; Doumenq, Pierre

    2017-04-01

    Chemical warfare agents are an actual threat and victims' decontamination is a main concern when mass exposure occurs. Skin decontamination with current protocols has been widely documented, as well as surface decontamination. However, considering hair ability to trap chemicals in vapour phase, we investigated hair decontamination after exposure to sulphur mustard simulants methyl salicylate and 2-chloroethyl ethyl sulphide. Four decontamination protocols were tested on hair, combining showering and emergency decontamination (use of Fuller's earth or Reactive Skin Decontamination Lotion RSDL ® ). Both simulants were recovered from hair after treatment, but contents were significantly reduced (42-85% content allowance). Showering alone was the least efficient protocol. Concerning 2-chloroethyl ethyl sulphide, protocols did not display significant differences in decontamination efficacy. For MeS, use of emergency decontaminants significantly increased showering efficacy (10-20% rise), underlining their usefulness before thorough decontamination. Our results highlighted the need to extensively decontaminate hair after chemical exposure. Residual amounts after decontamination are challenging, as their release from hair could lead to health issues. Copyright © 2016. Published by Elsevier B.V.

  1. The CREATIVE Decontamination Performance Evaluation Model

    National Research Council Canada - National Science Library

    Shelly, Erin E

    2008-01-01

    The project objective is to develop a semi-empirical, deterministic model to characterize and predict laboratory-scale decontaminant efficacy and hazards for a range of: chemical agents (current focus on HD...

  2. Options and strategies in decontamination for decommissioning: after safe enclosure or directly after shutdown. Experiences in 2012; Opciones y Estrategias en Descontaminacion para el Desmantelamiento: Desmantelamiento aplazado o inmediato. Experiencias en 2012

    Energy Technology Data Exchange (ETDEWEB)

    Sempere Belda, L.; Topf, C.; Moreira do Amaral, J. P.

    2013-07-01

    During the last years AREVA has been performing numerous large scale chemical decontaminations, including the simultaneous decontamination of the complete primary circuit and auxiliary systems ('Full System Decontamination'). Three of them have were completed during the course of the last twelve months, in the nuclear power plants of Chooz A in France and of Unterweser and Neckarwestheim 1 in Germany. This paper compares the consequences for the performance of the decontamination derived from the different decommissioning philosophies adopted: Immediate decommissioning after ceasing operation in the case of Unterweser and Neckarwestheim 1, and delayed dismantlement after safe enclosure (SAFSTORE) in the case of Chooz A. The authors, responsible for the application and process control also from a technical point of view, comment on the results obtained and on the differences between these approaches.

  3. Radiological survey and decontamination of the former main technical area (TA-1) at Los Alamos, New Mexico

    International Nuclear Information System (INIS)

    Ahlquist, A.J.; Stoker, A.K.; Trocki, L.K.

    1977-12-01

    A radiological survey was conducted on the undeveloped portions of the site of the former Main Technical Area (TA-1) of the Los Alamos Scientific Laboratory in north-central New Mexico. Between 1943 and 1965, research work on nuclear weapons was carried out in TA-1. The area was decontaminated and demolished in stages, and beginning in 1966 the land was given to Los Alamos County or sold to private interests. The survey disclosed traces of radioactive contamination undetected or considered insignificant during original demolition in the 1950s and 1960s. The remaining contamination was removed in 1975 and 1976 to levels considered to pose no health or safety hazards and, further, to the lowest levels considered practicable. Methods used in the survey included measurement techniques for detecting alpha emitters such as uranium and plutonium, extensive surface and subsurface soil sampling, and use of conventional health physics instrumentation to provide detailed information on approximately 16 hectares (40 acres) of land. As a result of the decontamination efforts, approximately 15,000 m 3 of contaminated or potentially contaminated material was removed to an approved radioactive waste disposal site on ERDA property. Full details of the methods, findings, decision criteria, and as-left conditions are documented

  4. MERCURY CONTAMINATED MATERIAL DECONTAMINATION METHODS: INVESTIGATION AND ASSESSMENT

    Energy Technology Data Exchange (ETDEWEB)

    M.A. Ebadian, Ph.D.

    2001-01-01

    Over the years mercury has been recognized as having serious impacts on human health and the environment. This recognition has led to numerous studies that deal with the properties of various mercury forms, the development of methods to quantify and speciate the forms, fate and transport, toxicology studies, and the development of site remediation and decontamination technologies. This report reviews several critical areas that will be used in developing technologies for cleaning mercury from mercury-contaminated surfaces of metals and porous materials found in many DOE facilities. The technologies used for decontamination of water and mixed wastes (solid) are specifically discussed. Many technologies that have recently appeared in the literature are included in the report. Current surface decontamination processes have been reviewed, and the limitations of these technologies for mercury decontamination are discussed. Based on the currently available technologies and the processes published recently in the literature, several processes, including strippable coatings, chemical cleaning with iodine/iodide lixiviant, chemisorbing surface wipes with forager sponge and grafted cotton, and surface/pore fixation through amalgamation or stabilization, have been identified as potential techniques for decontamination of mercury-contaminated metal and porous surfaces. Their potential merits and applicability are discussed. Finally, two processes, strippable coatings and chemical cleaning with iodine/iodide lixiviant, were experimentally investigated in Phase II of this project.

  5. Analysis of decontamination methods used at nuclear power plants and in other facilities. Research report

    International Nuclear Information System (INIS)

    Podlaha, Josef

    2011-10-01

    Methods used in the Czech Republic and in other countries are described. The following topics are treated: Introduction into decontamination; Chemical methods; Foam methods; Electrochemical methods; Mechanical methods; Other methods; Decontamination of civil engineering structures; Technologies suitable for disposal decontamination; and Effect of decontamination on waste management. (P.A.)

  6. Efficacy of scalp hair decontamination following exposure to vapours of sulphur mustard simulants 2-chloroethyl ethyl sulphide and methyl salicylate

    OpenAIRE

    Spiandore , Marie; Piram , Anne; Lacoste , Alexandre; Prevost , P.; Maloni , Pascal; TORRE , Franck; Asia , L.; Josse , D.; Doumenq , Pierre

    2017-01-01

    International audience; Chemical warfare agents are an actual threat and victims' decontamination is a main concern when mass exposure occurs. Skin decontamination with current protocols has been widely documented, as well as surface decontamination. However, considering hair ability to trap chemicals in vapour phase, we investigated hair decontamination after exposure to sulphur mustard simulants methyl salicylate and 2-chloroethyl ethyl sulphide. Four decontamination protocols were tested o...

  7. Present state and subjects for hereafter of technical development for decommissioning

    International Nuclear Information System (INIS)

    Ishikura, Takeshi; Onozawa, Teruo; Saishu, Sadanori

    1997-01-01

    As to the decommissioning of nuclear power facilities, it was confirmed that there is no technical problem which makes decommissioning impossible in the report of the nuclear power subcommittee of Advisory Committee for Energy. In OECD/NEA, the international joint research for exchanging the information and experience of the decommissioning projects has been carried out. In foreign countries, the decommissioning has been executed practically. As the disassembling techniques for structures, laser cutting, plasma are cutting, arc gouging and gas cutting, arc saw cutting, gas cutting and powder gas cutting, mechanical cutting and molded explosive cutting are described. As the disassembling techniques for concrete structures, diamond wire saw method, mechanical cutting, water jet cutting and the method of using disk cutter and mechanical wedge are described. As to decontamination techniques, decontamination before disassembling, decontamination of large equipment, and decontamination after disassembling by blast, electrolysis and chemical immersion are described. The technology for measuring the radiation before disassembling and the radiation of buildings and disassembled waste is reported. (K.I.)

  8. Radioactive decontamination

    International Nuclear Information System (INIS)

    1983-07-01

    This Code of Practice covers: (a) the decontamination of plant items, buildings and associated equipment; (b) decontamination of protective clothing; (c) simple personal decontamination; and (d) the basic mechanisms of contamination and their influence on decontaminability. (author)

  9. Evaluation of destructive methods for managing decontamination wastes

    International Nuclear Information System (INIS)

    Piciulo, P.L.; Adams, J.W.

    1986-01-01

    Results are discussed of a laboratory evaluation of destructive methods for processing chemical decontamination wastes. Incineration, acid digestion and wet-air oxidation are capable of degrading decontamination reagents and organic ion-exchange resins. The extent of destruction as a function of operating parameters was waste specific. The reagents used in the testing were: EDTA, oxalic acid, citric acid, picolinic acid and LND-101A

  10. Enhanced toxic cloud knockdown spray system for decontamination applications

    Science.gov (United States)

    Betty, Rita G [Rio Rancho, NM; Tucker, Mark D [Albuquerque, NM; Brockmann, John E [Albuquerque, NM; Lucero, Daniel A [Albuquerque, NM; Levin, Bruce L [Tijeras, NM; Leonard, Jonathan [Albuquerque, NM

    2011-09-06

    Methods and systems for knockdown and neutralization of toxic clouds of aerosolized chemical or biological warfare (CBW) agents and toxic industrial chemicals using a non-toxic, non-corrosive aqueous decontamination formulation.

  11. In vitro determination of skin decontamination efficacy using a water shower

    International Nuclear Information System (INIS)

    Reifenrath, W.G.

    1990-01-01

    The ability of a water shower to remove radioactivity from excised pig skin exposed to radiolabeled diisopropyl fluorophosphate and n-butyl 2-chloroethyl sulfide was determined. Skin samples were decontaminated 15 minutes after chemical exposures (1 mg/cm 2 ) and the distribution of radioactivity was determined 1 hour after decontamination. Compared to controls (no decontamination), shower decontamination reduced the evaporative loss of radioactivity from the skin surface after decontamination or reduced radioactive residues on the skin surface. Shower decontamination of skin at 15 minutes could not prevent penetration of radiolabel into the viable layers of skin or into fluid bathing the dermal surface of the skin, but was beneficial in reducing skin surface concentrations, which may lead to further exposure or contamination

  12. Effectiveness of Vaporous Hydrogen Peroxide for the Decontamination of Representative Military Materials

    National Research Council Canada - National Science Library

    Dutt, D. L; Turetsky, A. L; Brickhouse, M; Pfarr, J. W; McVey, I. F; Meilander, S. L; Janick, A. J; Schulte, S. L; Dallmier, A. W

    2004-01-01

    .... While many chemical decontamination methods, including aqueous hydrogen peroxide, have been used or are under development for direct application, few vaporous methods are being evaluated for decontamination efficacy (McDonnell, G. et al., 2002...

  13. CB decontamination for first responders

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, M.D.G.; Purdon, J.G.; Burczyk, A. [Defence Research and Development Canada Suffield, Ralston, AB (Canada)

    2006-07-01

    The Universal Containment System (UCS) is designed to contain, mitigate and decontaminate chemical, biological and radiological warfare agents. The UCS consists of a lightweight, tent-like enclosure filled with a water-based surface decontaminating foam (SDF). The Canadian government funded a project to advance the understanding of the behaviour of the UCS. This paper described the success of the project as well as the technological advances in the UCS formulation and equipment. Vapour desorption experiments were conducted in which SDF was applied onto 12 surfaces found in a typical office environment. Both mustard and nerve agent were studied on the test surfaces. Both scrubbing and non-scrubbing decontamination methods were tested. SDF effectively decontaminated the non-porous substances, particularly when the scrubbing procedure was used. Results were more complicated for the non-porous samples. A dye added to the agent was useful for determining the fate of the agent. Liquid phase studies were conducted in which the reaction between SDF and various agents were studied in the liquid phase in order to estimate the rate of reaction, the stoichiometry and the reaction products formed. Both SDF and the commercial decontamination agent CASCAD were found to effectively kill 100 per cent of anthrax spores. The significance of this project to first responders was considerable. Changes to the formulation and equipment of UCS will increase its usefulness and safety. Users will also have a better knowledge of the amount of decontamination needed for complete effectiveness in specific situations. Recommendations have been made for use of the product on a range of indoor surfaces. Field trials have shown the blast mitigation and agent decontamination ability of the foam under explosive situations. 15 refs., 4 tabs.

  14. Psychological stress for alternatives of decontamination of TMI-2 reactor building atmosphere. Technical report

    International Nuclear Information System (INIS)

    Baum, A.; Gatchel, R.; Streufert, S.; Baum, C.S.; Fleming, R.

    1980-08-01

    The purpose of the report is to consider the nature and level of psychological stress that may be associated with each of several alternatives for decontamination. The report briefly reviews some of the literature on stress, response to major disaster or life stressors, provides opinion on each decontamination alternative, and considers possible mitigative actions to reduce psychological stress. The report concludes that any procedure that is adapted for the decontamination of the reactor building atmosphere will result in some psychological stress. The stress, however, should abate as contamination is reduced and uncertainty is diminished. The advantages of the purge alternative are the rapid completion of the decontamination and the consequent elimination of future uncontrolled release. Severe stress effects are less likely if the duration of stressor exposure is reduced, if the feeling of public control is increased and if the degree of perceived safety is increased. The long delays, continued uncertainty, and possibility of uncontrolled release that characterize the other alternatives may offset the perception that they are safer. In addition, chronic stress could be a consequence of long delays and continued uncertainty

  15. Decontamination impacts on solidification

    International Nuclear Information System (INIS)

    Piciulo, P.L.; Davis, M.S.

    1985-01-01

    The increased occupational exposure resulting from the accumulation of activated corrosion products in the primary system of LWRs has led to the development of chemical methods to remove the contamination. In the past, the problem of enhanced migration of radionuclides away from trenches used to dispose of low-level radioactive waste, has been linked to the presence, at the disposal unit, of chelating or complexing agents such as those used in decontamination processes. These agents have further been found to reduce the normal sorptive capacity of soils for radionuclides. The degree to which these agents inhibit the normal sorptive processes is dependent on the type of complexing agent, the radionuclide of concern, the soil properties and whether the nuclide is present as a complex or is already sorbed to the soil. Since the quantity of reagent employed in a full system decontamination is large (200 to 25,000 kg), the potential for enhanced migration of radionuclides from a site used to dispose of the decontamination wastes should be addressed and guidelines established for the safe disposal of these wastes

  16. Method to chemically decontaminate nuclear reactor components

    International Nuclear Information System (INIS)

    Bertholdt, H.O.

    1984-01-01

    The large decontamination of components of the primary circuit of activated corrosion products in the oxide layer of the structure materials firstly involves an approx. 1 hour oxidation treatment with alkali permanganate solution. Following intermediate rinsing with deionate, they are etched with an inhibited citrate-oxalate solution for 5-20 hours. This is followed by post-treatment with a citric acid/H2O2 solution containing suspended fiber particles. (orig./PW)

  17. Testing and evaluation of electrokinetic decontamination of concrete

    International Nuclear Information System (INIS)

    DePaoli, D.W.; Harris, M.T.; Ally, M.R.

    1996-10-01

    The goals and objectives of the technical task plan (TTP) are to (1) describe the nature and extent of concrete contamination within the Department of Energy (DOE) complex and emerging and commercial technologies applicable to these problems; (2) to match technologies to the concrete problems and recommend up to four demonstrations; (3) to initiate recommended demonstrations; and (4) to continue investigation and evaluation of the application of electrokinetic decontamination processes to concrete. This document presents findings of experimental and theoretical studies of the electrokinetic decontamination (EK) process and their implications for field demonstrations. This effort is an extension of the work performed under TTP 142005, ''Electroosmotic Concrete Decontamination. The goals of this task were to determine the applicability of EK for treating contaminated concrete and, if warranted, to evaluate EK as a potential technology for demonstration. 62 refs

  18. Use of citric acid for large parts decontamination

    International Nuclear Information System (INIS)

    Holland, M.E.

    1979-01-01

    Laboratory and field studies have been performed to identify and evaluate chemical decontamination agents to replace ammonium carbonate, an environmentally unacceptable compound, in the decontamination facility for large process equipment at the Portsmouth Gaseous Diffusion Plant. Preliminary screening of over 40 possible decontamination agents on the basis of efficiency, availability, toxicity, cost, corrosiveness, and practicality indicated sodium carbonate and citric acid to be the most promising. Extensive laboratory studies were performed with these two reagents. Corrosion rates, decontamination factors, uranium recovery efficiencies, technetium ( 99 Tc)/ion exchange removal effects, and possible environmental impacts were determined or investigated. Favorable results were found in all areas. Detailed monitoring and analysis during two-week trial periods in which sodium carbonate and citric acid were used in the large parts decontamination facility resulted in similar evaluation and conclusions. Because it has cleaning properties not possessed by sodium carbonate, and because it eliminated several operational problems by incorporating two acidic decontamination reagents (citric and nitric acids) instead of one basic reagent (sodium or ammonium carbonate) and one acidic reagent (nitric acid), citric acid was selected for one-year field testing. On the basis of its excellent performance in the field tests, citric acid is recommended as a permanent replacement for ammonium carbonate in the decontamination facility for large process equipment

  19. Pipe Decontamination Involving String-Foam Circulation

    International Nuclear Information System (INIS)

    Turchet, J.P.; Estienne, G.; Fournel, B.

    2002-01-01

    Foam applications number for nuclear decontamination purposes has recently increased. The major advantage of foam decontamination is the reduction of secondary liquid wastes volumes. Among foam applications, we focus on foam circulation in contaminated equipment. Dynamic properties of the system ensures an homogeneous and rapid effect of the foam bed-drifted chemical reagents present in the liquid phase. This paper describes a new approach of foam decontamination for pipes. It is based on an alternated air and foam injections. We called it 'string-foam circulation'. A further reduction of liquid wastes is achieved compared to continuous foam. Secondly, total pressure loss along the pipe is controlled by the total foam length in the pipe. It is thus possible to clean longer pipes keeping the pressure under atmospheric pressure value. This ensures the non dispersion of contamination. This study describes experimental results obtained with a neutral foam as well with an acid foam on a 130 m long loop. Finally, the decontamination of a 44 meters pipe is presented. (authors)

  20. Examining the decontaminability of surfaces from the beginnings of nuclear technology

    International Nuclear Information System (INIS)

    Kunze, S.

    2003-01-01

    Parallel with the development of nuclear technology in the 1950s, methods of examining the decontaminability of surface materials were elaborated, improved, and partly standardized in many countries. In 1988, ISO 8690 was adopted as an internationally accepted method of examination (technically identical to DIN 25 415, Part 1). A first range of coatings for nuclear applications were compiled from the large number of commercial products available on the market on the basis of the test method developed since 1962 at the Karlsruhe Nuclear Research Center and then at the Karlsruhe Research Center. Subsequently, the continuously improved test method was used to study, in mainly chemically curing two-component coatings, the reduction of gloss by dulling agents and fillers as well as various shades of color. Floor and container coatings were also examined for their resistance to radiation and to chemicals as well as wear. (orig.) [de

  1. Current and emerging strategies for organophosphate decontamination: special focus on hyperstable enzymes.

    Science.gov (United States)

    Jacquet, Pauline; Daudé, David; Bzdrenga, Janek; Masson, Patrick; Elias, Mikael; Chabrière, Eric

    2016-05-01

    Organophosphorus chemicals are highly toxic molecules mainly used as pesticides. Some of them are banned warfare nerve agents. These compounds are covalent inhibitors of acetylcholinesterase, a key enzyme in central and peripheral nervous systems. Numerous approaches, including chemical, physical, and biological decontamination, have been considered for developing decontamination methods against organophosphates (OPs). This work is an overview of both validated and emerging strategies for the protection against OP pollution with special attention to the use of decontaminating enzymes. Considerable efforts have been dedicated during the past decades to the development of efficient OP degrading biocatalysts. Among these, the promising biocatalyst SsoPox isolated from the archaeon Sulfolobus solfataricus is emphasized in the light of recently published results. This hyperthermostable enzyme appears to be particularly attractive for external decontamination purposes with regard to both its catalytic and stability properties.

  2. Decontamination of Metal Ions in Soil by Supercritical CO2 Extraction with Crown Ether

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jihe; Park, Kwangheon [Kyunghee University, Yongin (Korea, Republic of)

    2015-05-15

    Previous decontamination methods have shortcomings in that they produce additional waste due to the usage of solutions with chemical toxicity. Hence, demand is strong for new decontamination methods that can guarantee effective decontamination while decreasing the chemical solution. In particular, methods using supercritical CO2 as a means of decontamination are currently in progress. This study examines the method of decontaminating metallic ions inside soil using supercritical CO2. This paper examined the effects of extracting metallic ions inside soil using supercritical CO2 and crown ether as the ligand. It was confirmed that extraction effectiveness increases following greater usage of ligand and co-ligand, with a drastic increase in extraction effectiveness when using extracts over a certain dose. Moreover, it was shown that if the usage of ligand and additive decreases, the extraction ratio also decreases.

  3. Decontamination of Metal Ions in Soil by Supercritical CO2 Extraction with Crown Ether

    International Nuclear Information System (INIS)

    Park, Jihe; Park, Kwangheon

    2015-01-01

    Previous decontamination methods have shortcomings in that they produce additional waste due to the usage of solutions with chemical toxicity. Hence, demand is strong for new decontamination methods that can guarantee effective decontamination while decreasing the chemical solution. In particular, methods using supercritical CO2 as a means of decontamination are currently in progress. This study examines the method of decontaminating metallic ions inside soil using supercritical CO2. This paper examined the effects of extracting metallic ions inside soil using supercritical CO2 and crown ether as the ligand. It was confirmed that extraction effectiveness increases following greater usage of ligand and co-ligand, with a drastic increase in extraction effectiveness when using extracts over a certain dose. Moreover, it was shown that if the usage of ligand and additive decreases, the extraction ratio also decreases

  4. Urban Decontamination Experience at Pripyat Ukraine - 13526

    Energy Technology Data Exchange (ETDEWEB)

    Paskevych, Sergiy [Institute for Safety Problems of Nuclear Power Plants, National Academy of Sciences of Ukraine, 36 a Kirova str. Chornobyl, Kiev region, 07200 (Ukraine); Voropay, Dmitry [Federal State Unitary Enterprise ' Russian State Center of Inventory and Registration and Real Estate - Federal Bureau of Technical Inventory' , 37-2 Bernadsky Prospekt, Moscow Russia 119415 (Russian Federation); Schmieman, Eric [Battelle Memorial Institute, PO Box 999 MSIN K6-90, Richland, WA 99352 (United States)

    2013-07-01

    This paper describes the efficiency of radioactive decontamination activities of the urban landscape in the town of Pripyat, Ukraine. Different methods of treatment for various urban infrastructure and different radioactive contaminants are assessed. Long term changes in the radiation condition of decontaminated urban landscapes are evaluated: 1. Decontamination of the urban system requires the simultaneous application of multiple methods including mechanical, chemical, and biological. 2. If a large area has been contaminated, decontamination of local areas of a temporary nature. Over time, there is a repeated contamination of these sites due to wind transport from neighboring areas. 3. Involvement of earth-moving equipment and removal of top soil by industrial method achieves 20-fold reduction in the level of contamination by radioactive substances, but it leads to large amounts of waste (up to 1500 tons per hectare), and leads to the re-contamination of treated areas due to scatter when loading, transport pollutants on the wheels of vehicles, etc.. (authors)

  5. Effects of some decontaminating agents on the purification of radioactive sewage; Influence de quelques agents decontaminants sur l'epuration d'eaux residuaires radioactives

    Energy Technology Data Exchange (ETDEWEB)

    Cantel, J; Cohen, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The efficiency of different decontaminating agents on the processing of radioactive sewage was studied. Versene, which is often used, decreases very slightly the efficiency of the chemical treatment. (author) [French] On a etudie l'influence de differents agents decontaminants sur l'efficacite du traitement d'eaux residuaires radioactives. Le Versene, souvent utilise, ne gene pratiquement pas l'efficacite du traitement chimique employe. (auteur)

  6. Granulated decontamination formulations

    Science.gov (United States)

    Tucker, Mark D.

    2007-10-02

    A decontamination formulation and method of making that neutralizes the adverse health effects of both chemical and biological compounds, especially chemical warfare (CW) and biological warfare (BW) agents, and toxic industrial chemicals. The formulation provides solubilizing compounds that serve to effectively render the chemical and biological compounds, particularly CW and BW compounds, susceptible to attack, and at least one reactive compound that serves to attack (and detoxify or kill) the compound. The formulation includes at least one solubilizing agent, a reactive compound, a sorbent additive, and water. A highly adsorbent sorbent additive (e.g., amorphous silica, sorbitol, mannitol, etc.) is used to "dry out" one or more liquid ingredients into a dry, free-flowing powder that has an extended shelf life, and is more convenient to handle and mix in the field.

  7. MERCURY CONTAMINATED MATERIAL DECONTAMINATION METHODS: INVESTIGATION AND ASSESSMENT; TOPICAL

    International Nuclear Information System (INIS)

    M.A. Ebadian, Ph.D.

    2001-01-01

    Over the years mercury has been recognized as having serious impacts on human health and the environment. This recognition has led to numerous studies that deal with the properties of various mercury forms, the development of methods to quantify and speciate the forms, fate and transport, toxicology studies, and the development of site remediation and decontamination technologies. This report reviews several critical areas that will be used in developing technologies for cleaning mercury from mercury-contaminated surfaces of metals and porous materials found in many DOE facilities. The technologies used for decontamination of water and mixed wastes (solid) are specifically discussed. Many technologies that have recently appeared in the literature are included in the report. Current surface decontamination processes have been reviewed, and the limitations of these technologies for mercury decontamination are discussed. Based on the currently available technologies and the processes published recently in the literature, several processes, including strippable coatings, chemical cleaning with iodine/iodide lixiviant, chemisorbing surface wipes with forager sponge and grafted cotton, and surface/pore fixation through amalgamation or stabilization, have been identified as potential techniques for decontamination of mercury-contaminated metal and porous surfaces. Their potential merits and applicability are discussed. Finally, two processes, strippable coatings and chemical cleaning with iodine/iodide lixiviant, were experimentally investigated in Phase II of this project

  8. Volume reduction and material recirculation by freon decontamination

    International Nuclear Information System (INIS)

    Berners, O.; Buhmann, D.; Yamashita, Y.; Yoshiaki, M.

    1989-01-01

    This paper discusses the use of freon in a large variety of decontamination in the nuclear and non-nuclear fields. As far as the contamination is loose or smerable, surfaces of nearly all materials can be decontaminated. Freon is electrically non-conductive, chemically neutral and has a low surface tension. So it is capable of creeping under the contaminant and loosening or dissolving it. Used freon can be collected, cleaned and recirculated. Its cleaning can be done easily by evaporation at its lower vapor point of about 48 degrees C (104 degrees F). Good decontamination results could be achieved, expensive materials, tools and equipment could be recirculated. Big volumes of materials could get separated from their contaminants, which is the real radioactive waste. Freon decontamination is an effective, overall economical and approved technology to volume reduction and material recirculation

  9. Preliminary evaluation of military, commercial and novel skin decontamination products against a chemical warfare agent simulant (methyl salicylate).

    Science.gov (United States)

    Matar, Hazem; Guerreiro, Antonio; Piletsky, Sergey A; Price, Shirley C; Chilcott, Robert P

    2016-01-01

    Rapid decontamination is vital to alleviate adverse health effects following dermal exposure to hazardous materials. There is an abundance of materials and products which can be utilised to remove hazardous materials from the skin. In this study, a total of 15 products were evaluated, 10 of which were commercial or military products and five were novel (molecular imprinted) polymers. The efficacies of these products were evaluated against a 10 µl droplet of (14)C-methyl salicylate applied to the surface of porcine skin mounted on static diffusion cells. The current UK military decontaminant (Fuller's earth) performed well, retaining 83% of the dose over 24 h and served as a benchmark to compare with the other test products. The five most effective test products were Fuller's earth (the current UK military decontaminant), Fast-Act® and three novel polymers [based on itaconic acid, 2-trifluoromethylacrylic acid and N,N-methylenebis(acrylamide)]. Five products (medical moist-free wipes, 5% FloraFree™ solution, normal baby wipes, baby wipes for sensitive skin and Diphotérine™) enhanced the dermal absorption of (14)C-methyl salicylate. Further work is required to establish the performance of the most effective products identified in this study against chemical warfare agents.

  10. Decontamination of lead by fusion (1962); Decontamination du plomb par fusion (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Boutot, P; Giachetto, L; Capitaine, A [Commissariat a l' Energie Atomique, Centre de Production de Plutonium, Marcoule (France). Centre d' Etudes Nucleaires

    1962-07-01

    Various attempts to decontaminate using mechanical and chemical methods having given questionable results, a fusion method has been developed. The apparatus consists of a propane-heated oven fitted with a steel crucible of 1 400 kg capacity, with two ventilation systems, and with a vacuum gauge for preventing the diffusion of toxic gases. There are three operational controls : 1. On the samples taken before during and after the operation, 2. On the plugs taken from the ingots, 3. On the ingot itself. The continuous sanitary control is done by a radioactive aerosol recorder and by periodic sampling. This decontamination process will be improved, especially as far as the productivity and the safety precautions are concerned. (authors) [French] Divers essais de decontamination par voies mecaniques et chimiques ayant donne des resultats discutables, un procede par fusion a ete mis au point. L'appareil se compose d'un four, chauffe au propane, muni d'un creuset en acier d'une capacite de 1 400 kg, de deux systemes de ventilation et d'un deprimometre afin d'eviter la diffusion de vapeurs nocives. Trois controles d'activite sont effectues: 1. sur des echantillons preleves avant, pendant et apres l'operation, 2. sur des carottages realises sur les lingots, 3. sur le lingot lui-meme. Le controle sanitaire permanent est assure par un enregistreur d'aerosols radioactifs et par des prelevements periodiques. Ce procede de decontamination doit encore etre ameliore, principalement en ce qui concerne la productivite et la securite. (auteurs)

  11. Correlation Study of Magnetite Dissolution in Hybrid Decontamination Process

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seon-Byeong; Won, Hui-Jun; Park, Jung-Sun; Park, Sang-Yoon; Moon, Jei-Kwon; Choi, Wang-Kyu [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    In the operating plants, the localized corrosion on SG tubes which are transporters of thermal energy to the secondary side lowers the reduction heat transfer efficiency as well as degrades the lifetime of SG. Magnetite, Fe3O4, is a commonly found corrosion product on the inner surface of reactor coolant system. Simply magnetite can be reduced to hematite, Fe{sub 2}O{sub 3}, and further to iron when oxygen is limited or ample reducing agents are supplied. Along this line, number of decontamination processes has been developed since 1970s and most of them contain organic acid and additive chelating agents. However, many reports have pointed out the negative environmental effect of those chemicals, and currently there are new approaches to overcome the limited decontamination efficiency and large volume of secondary waste from other alternate processes without using such those organic chemicals. In present study, we investigated the magnetite dissolution in HyBRID solution as newly developing decontamination process. As a preliminary study for empirical modeling of decontamination by HyBRID solution, simply correlation study between variable and magnetite dissolution was introduced with studied mechanism and experimental results.

  12. Decontamination of radionuclides on construction materials

    International Nuclear Information System (INIS)

    Samuleev, P.V.; Andrews, W.S.; Creber, K.A.M.; Velicogna, D.

    2013-01-01

    A wide variety of materials can become contaminated by radionuclides, either from a terrorist attack or an industrial or nuclear accident. The final disposition of these materials depends, in large part, on the effectiveness of decontamination measures. This study reports on investigations into the decontamination of a selection of building materials. The aim has been to find an effective, easy-to-use and inexpensive decontamination system for radionuclides of cesium and cobalt, considering both the chemical and physical nature of these potential contaminants. The basic method investigated was surface washing, due to its ease and simplicity. In the present study, a basic decontamination formulation was modified by adding isotope-specific sequestering agents, to enhance the removal of cesium(I) and cobalt(II) from such construction materials as concrete, marble, aluminum and painted steel. Spiking solutions contained 134 Cs or 60 Co, which were prepared by neutron activation in the SLOWPOKE-2 nuclear reactor facility at the Royal Military College of Canada. Gamma spectroscopy was used to determine the decontamination efficiency. The results showed that the addition of sequestering agents generally improved the radiological decontamination. Although the washing of both cesium and cobalt from non-porous materials, such as aluminum and painted steel, achieved a 90-95 % removal, the decontamination of concrete and marble was more challenging, due to the porous nature of the materials. Nevertheless, the removal efficiency from 6-year-old concrete increased from 10 % to approximately 50 % for cobalt(II), and from 18 to 55 % for cesium(I), with the use of isotope binding agents, as opposed to a simple water wash. (author)

  13. Decontamination of chemical and biological warfare (CBW) agents using an atmospheric pressure plasma jet (APPJ)

    Science.gov (United States)

    Herrmann, H. W.; Henins, I.; Park, J.; Selwyn, G. S.

    1999-05-01

    The atmospheric pressure plasma jet (APPJ) [A. Schütze et al., IEEE Trans. Plasma Sci. 26, 1685 (1998)] is a nonthermal, high pressure, uniform glow plasma discharge that produces a high velocity effluent stream of highly reactive chemical species. The discharge operates on a feedstock gas (e.g., He/O2/H2O), which flows between an outer, grounded, cylindrical electrode and an inner, coaxial electrode powered at 13.56 MHz rf. While passing through the plasma, the feedgas becomes excited, dissociated or ionized by electron impact. Once the gas exits the discharge volume, ions and electrons are rapidly lost by recombination, but the fast-flowing effluent still contains neutral metastable species (e.g., O2*, He*) and radicals (e.g., O, OH). This reactive effluent has been shown to be an effective neutralizer of surrogates for anthrax spores and mustard blister agent. Unlike conventional wet decontamination methods, the plasma effluent does not cause corrosion and it does not destroy wiring, electronics, or most plastics, making it highly suitable for decontamination of sensitive equipment and interior spaces. Furthermore, the reactive species in the effluent rapidly degrade into harmless products leaving no lingering residue or harmful by-products.

  14. Development of standards for chemical and biological decontamination of buildings and structures affected by terrorism

    Energy Technology Data Exchange (ETDEWEB)

    Lumley, T.C.; Volchek, K.; Fingas, M. [Environment Canada, Ottawa, ON (Canada). Emergencies Science and Technology Division, Environmental Technology Centre, Science and Technology Branch; Hay, A.W.M. [Leeds Univ., Leeds (United Kingdom)

    2006-07-01

    Currently, there are no suitable standards for determining levels of safety when reoccupying a building that has been recommissioned following a biological or chemical attack. For that reason, this study focused on developing clean-up standards for decontaminating buildings and construction materials after acts of terrorism. Several parameters must be assessed when determining the course of action to decontaminate toxic agents and to rehabilitate facilities. First, the hazardous substance must be positively identified along with the degree of contamination and information on likely receptors. Potential exposure route is also a key consideration in the risk assessment process. A key objective of the study was to develop specific guidelines for ascertaining and defining clean. In particular, standards for chemical and biological agents that pose a real or potential risk for use as agents of terrorism will be developed. The selected agents for standards development were ammonia, fentanyl, malathion, mustard gas, potassium cyanide, ricin, sarin, hepatitis A virus, and bacillus anthracis. The standards will be developed by establishing the relationship between the amount of exposure and expected health effects; assessing real and potential risks by identifying individuals at risk and consideration of all exposure routes; and, characterizing the risk to determine the potential for toxicity or infectivity. For non-carcinogens, this was done through the analysis of other known guidelines. Cancer-slope factors will be considered for carcinogens. The standards will be assessed in the laboratory using animal models. The guidelines and standards are intended for first-responders and are scheduled for development by the end of 2006. 15 refs., 3 tabs.

  15. ASSESSING CHEMICAL HAZARDS AT THE PLUTONIUM FINISHING PLANT FOR PLANNING FUTURE DECONTAMINATION AND DECOMMISSIONING

    International Nuclear Information System (INIS)

    HOPKINS, A.M.; KLOS, D.B.; MINETT, M.J.

    2007-01-01

    This paper documents the fiscal year (FY) 2006 assessment to evaluate potential chemical and radiological hazards associated with vessels and piping in the former plutonium process areas at Hanford's Plutonium Finishing Plant (PFP). Evaluations by PFP engineers as design authorities for specific systems and other subject-matter experts were conducted to identify the chemical hazards associated with transitioning the process areas for the long-term layup of PFP before its eventual final decontamination and decommissioning (D and D). D and D activities in the main process facilities were suspended in September 2005 for a period of between 5 and 10 years. A previous assessment conducted in FY 2003 found that certain activities to mitigate chemical hazards could be deferred safely until the D and D of PFP, which had been scheduled to result in a slab-on-grade condition by 2009. As a result of necessary planning changes, however, D and D activities at PFP will be delayed until after the 2009 time frame. Given the extended project and plant life, it was determined that a review of the plant chemical hazards should be conducted. This review to determine the extended life impact of chemicals is called the ''Plutonium Finishing Plant Chemical Hazards Assessment, FY 2006''. This FY 2006 assessment addresses potential chemical and radiological hazard areas identified by facility personnel and subject-matter experts who reevaluated all the chemical systems (items) from the FY 2003 assessment. This paper provides the results of the FY 2006 chemical hazards assessment and describes the methodology used to assign a hazard ranking to the items reviewed

  16. Vesicants and nerve agents in chemical warfare. Decontamination and treatment strategies for a changed world.

    Science.gov (United States)

    Devereaux, Asha; Amundson, Dennis E; Parrish, J S; Lazarus, Angeline A

    2002-10-01

    Vesicants and nerve agents have been used in chemical warfare for ages. They remain a threat in today's altered political climate because they are relatively simple to produce, transport, and deploy. Vesicants, such as mustard and lewisite, can affect the skin, eyes, respiratory system, and gastrointestinal system. They leave affected persons at risk for long-term effects. Nerve agents, such as tabun, sarin, soman, and VX, hyperstimulate the muscarinic and nicotinic receptors of the nervous system. Physicians need to familiarize themselves with the clinical findings of such exposures and the decontamination and treatment strategies necessary to minimize injuries and deaths.

  17. Decontamination of Belarus research reactor installation by strippable coatings

    International Nuclear Information System (INIS)

    Voronik, N.I.; Shatilo, N.N.

    2002-01-01

    The goal of this study was to develop new strippable coatings using water-based solutions of polyvinyl alcohol and active additives for decontamination of research reactor equipment. The employment of strippable coatings makes it possible to minimize the quantity of liquid radioactive waste. The selection of strippable decontaminating coatings was carried out on the basis of general requirements to decontaminating solutions: successfully dissolve corrosion deposits; ensure the desorption of radionuclides from the surfaces and the absence of resorption; introduce minimal corrosion effect of construction materials; to be relatively cheap and available in reagents. The decontaminating ability and adhesion properties of these coatings depending on metal and deposit sorts were investigated. Research on the chemical stability of solid wastes was carried out. The data obtained were the base for recommendations on waste management procedure for used films and pastes. A full-scale case-study analysis was performed for comparing strippable coatings with decontaminating solutions. (author)

  18. RSDL decontamination of human skin contaminated with the nerve agent VX.

    Science.gov (United States)

    Thors, L; Lindberg, S; Johansson, S; Koch, B; Koch, M; Hägglund, L; Bucht, A

    2017-03-05

    Dermal exposure to low volatile organophosphorus compounds (OPC) may lead to penetration through the skin and uptake in the blood circulation. Skin decontamination of toxic OPCs, such as pesticides and chemical warfare nerve agents, might therefore be crucial for mitigating the systemic toxicity following dermal exposure. Reactive skin decontamination lotion (RSDL) has been shown to reduce toxic effects in animals dermally exposed to the nerve agent VX. In the present study, an in vitro flow-through diffusion cell was utilized to evaluate the efficacy of RSDL for decontamination of VX exposed to human epidermis. In particular, the impact of timing in the initiation of decontamination and agent dilution in water was studied. The impact of the lipophilic properties of VX in the RSDL decontamination was additionally addressed by comparing chemical degradation in RSDL and decontamination efficacy between the VX and the hydrophilic OPC triethyl phosphonoacetate (TEPA). The epidermal membrane was exposed to 20, 75 or 90% OPC diluted in deionized water and the decontamination was initiated 5, 10, 30, 60 or 120min post-exposure. Early decontamination of VX with RSDL, initiated 5-10min after skin exposure, was very effective. Delayed decontamination initiated 30-60min post-exposure was less effective but still the amount of penetrated agent was significantly reduced, while further delayed start of decontamination to 120min resulted in very low efficacy. Comparing RSDL decontamination of VX with that of TEPA showed that the decontamination efficacy at high agent concentrations was higher for VX. The degradation mechanism of VX and TEPA during decontamination was dissected by 31 P NMR spectroscopy of the OPCs following reactions with RSDL and its three nucleophile components. The degradation rate was clearly associated with the high pH of the specific solution investigated; i.e. increased pH resulted in a more rapid degradation. In addition, the solubility of the OPC in RSDL

  19. Environmental decontamination

    International Nuclear Information System (INIS)

    Cristy, G.A.; Jernigan, H.C.

    1981-02-01

    The record of the proceedings of the workshop on environmental decontamination contains twenty-seven presentations. Emphasis is placed upon soil and surface decontamination, the decommissioning of nuclear facilities, and assessments of instrumentation and equipment used in decontamination

  20. Decontamination processes for waste glass canisters

    International Nuclear Information System (INIS)

    Rankin, W.N.

    1982-01-01

    A Defense Waste Processing Facility (DWPF) is currently being designed to convert Savannah River Plant liquid, high-level radioactive waste into a solid form, such as borosilicate glass. To prevent the spread of radioactivity, the outside of the canisters of waste glass must have very low levels of smearable radioactive contamination before they are removed from the DWPF. Several techniques were considered for canister decontamination: high-pressure water spray, electropolishing, chemical dissolution, and abrasive blasting. An abrasive blasting technique using a glass frit slurry has been selected for use in the DWPF. No additional equipment is needed to process waste generated from decontamination. Frit used as the abrasive will be mixed with the waste and fed to the glass melter. In contrast, chemical and electrochemical techniques require more space in the DWPF, and produce large amounts of contaminated by-products, which are difficult to immobilize by vitrification

  1. Considerations related to the decontamination of houses in Goiania: Limitations and implications

    International Nuclear Information System (INIS)

    da Silva, C.J.; Delgado, J.U.; Luiz, M.T.; Cunha, P.G.; Barros, P.D.

    1991-01-01

    We are considering some aspects related to the decontamination activities of about 50 houses affected by 137 Cs in Goiania. We describe the way these contaminations occurred, the instruments used, and the procedures. We also discuss the dose limits established for decontamination and the consequences resulting from this action. We call attention to the importance of not only the technical aspects in such activities but also the psycho-social implications resulting from them

  2. Environmental decontamination

    Energy Technology Data Exchange (ETDEWEB)

    Cristy, G.A.; Jernigan, H.C. (eds.)

    1981-02-01

    The record of the proceedings of the workshop on environmental decontamination contains twenty-seven presentations. Emphasis is placed upon soil and surface decontamination, the decommissioning of nuclear facilities, and assessments of instrumentation and equipment used in decontamination. (DLS)

  3. Development of chemical decontamination for low level radioactive wastes

    International Nuclear Information System (INIS)

    Ichikawa, Seigo; Omata, Kazuo; Obinata, Hiroshi; Nakajima, Yoshihiko; Kanamori, Osamu.

    1995-01-01

    During routine intermittent inspection and maintenance at nuclear power plants, a considerable quantity of low level radioactive waste is generated requiring release from the nuclear site or treating additionally. To decontaminate this waste for safe release from the nuclear power plant, the first step could be washing the waste in Methylene chloride, CH 2 Cl 2 , to remove most of the paint coating. However, CH 2 Cl 2 washing does not completely remove the paint coating from the waste, which in the next step is shot blasted with plastic bead media to loose and remove the remaining paint coating. Following in succession, in the third step, the waste is washed in a chelate solution, after which most waste is decontaminated and suitable to be released for recycling. The residual chelate solution may be decomposed into nontoxic carbon dioxide and water by an electrolysis process and then safely discharged into the environment. (author)

  4. Control of radiation exposures by decontamination

    International Nuclear Information System (INIS)

    LeSurf, J.E.

    1981-01-01

    The radiation exposures of workers at light water and heavy water cooled reactors can be reduced by dilute chemical decontamination as exemplified by the CAN-DECON process. The cost effectiveness of the CAN-DECON process is illustrated by actual service experience and by hypothetical cases

  5. System decontamination as a tool to control radiation fields

    Energy Technology Data Exchange (ETDEWEB)

    Riess, R.; Bertholdt, H.O. [Siemens Power Generation Group, Erlangen (Germany)

    1995-03-01

    Since chemical decontamination of the Reactor Coolant Systems (RCS) and subsystems has the highest potential to reduce radiation fields in a short term this technology has gained an increasing importance. The available decontamination process at Siemens, i.e., the CORD processes, will be described. It is characterized by using permanganic acid for preoxidation and diluted organic acid for the decontamination step. It is a regenerative process resulting in very low waste volumes. This technology has been used frequently in Europe and Japan in both RCS and subsystems. An overview will be given i.e. on the 1993 applications. This overview will include plant, scope, date of performance, system volume specal features of the process removed activities, decon factor time, waste volumes, and personnel dose during decontamination. This overview will be followed by an outlook on future developments in this area.

  6. Continuum Model for Decontamination of Chemical Warfare Agent from a Rubbery Polymer using the Maxwell-Stefan Formulation

    Science.gov (United States)

    Varady, Mark; Bringuier, Stefan; Pearl, Thomas; Stevenson, Shawn; Mantooth, Brent

    Decontamination of polymers exposed to chemical warfare agents (CWA) often proceeds by application of a liquid solution. Absorption of some decontaminant components proceed concurrently with extraction of the CWA, resulting in multicomponent diffusion in the polymer. In this work, the Maxwell-Stefan equations were used with the Flory-Huggins model of species activity to mathematically describe the transport of two species within a polymer. This model was used to predict the extraction of the nerve agent O-ethyl S-[2(diisopropylamino)ethyl] methylphosphonothioate (VX) from a silicone elastomer into both water and methanol. Comparisons with experimental results show good agreement with minimal fitting of model parameters from pure component uptake data. Reaction of the extracted VX with sodium hydroxide in the liquid-phase was also modeled and used to predict the overall rate of destruction of VX. Although the reaction proceeds more slowly in the methanol-based solution compared to the aqueous solution, the extraction rate is faster due to increasing VX mobility as methanol absorbs into the silicone, resulting in an overall faster rate of VX destruction.

  7. Decontamination tests on tritium-contaminated materials

    International Nuclear Information System (INIS)

    Boutot, P.; Schipfer, P.

    1967-01-01

    These tests are designed to try out various processes liable to be applied to the decontamination of a material contaminated with tritium. The samples are thin stainless- steel slabs contaminated in the laboratory with elements extracted from industrial installations. The measurement of the initial and residual activities is carried out using an open-window BERTHOLD counter. The best results are obtained by passing a current of pre-heated (300 deg. C) air containing water vapour. This process makes it possible to reach a decontamination factor of 99.5 per cent in 4 hours. In a vacuum, the operation has to be prolonged to 100 hours in order to obtain a decontamination factor of 99.2 per cent. Wet-chemical or electrolytic treatments are efficient but their use is limited by the inherent corrosion risks. A study of the reappearance of the contamination has made it possible to observe that this phenomenon occurs whatever the process used. (authors) [fr

  8. Pathogen Decontamination of Food Crop Soil: A Review.

    Science.gov (United States)

    Gurtler, Joshua B

    2017-09-01

    The purpose of this review is to delineate means of decontaminating soil. This information might be used to mitigate soil-associated risks of foodborne pathogens. The majority of the research in the published literature involves inactivation of plant pathogens in soil, i.e., those pathogens harmful to fruit and vegetable production and ornamental plants. Very little has been published regarding the inactivation of foodborne human pathogens in crop soil. Nevertheless, because decontamination techniques for plant pathogens might also be useful methods for eliminating foodborne pathogens, this review also includes inactivation of plant pathogens, with appropriate discussion and comparisons, in the hopes that these methods may one day be validated against foodborne pathogens. Some of the major soil decontamination methods that have been investigated and are covered include chemical decontamination (chemigation), solarization, steaming, biofumigation, bacterial competitive exclusion, torch flaming, microwave treatment, and amendment with biochar. Other innovative means of inactivating foodborne pathogens in soils may be discovered and explored in the future, provided that these techniques are economically feasible in terms of chemicals, equipment, and labor. Food microbiology and food safety researchers should reach out to soil scientists and plant pathologists to create links where they do not currently exist and strengthen relationships where they do exist to take advantage of multidisciplinary skills. In time, agricultural output and the demand for fresh produce will increase. With advances in the sensitivity of pathogen testing and epidemiological tracebacks, the need to mitigate preharvest bacterial contamination of fresh produce will become paramount. Hence, soil decontamination technologies may become more economically feasible and practical in light of increasing the microbial safety of fresh produce.

  9. Decontamination of adsorbed chemical warfare agents on activated carbon using hydrogen peroxide solutions.

    Science.gov (United States)

    Osovsky, Ruth; Kaplan, Doron; Nir, Ido; Rotter, Hadar; Elisha, Shmuel; Columbus, Ishay

    2014-09-16

    Mild treatment with hydrogen peroxide solutions (3-30%) efficiently decomposes adsorbed chemical warfare agents (CWAs) on microporous activated carbons used in protective garments and air filters. Better than 95% decomposition of adsorbed sulfur mustard (HD), sarin, and VX was achieved at ambient temperatures within 1-24 h, depending on the H2O2 concentration. HD was oxidized to the nontoxic HD-sulfoxide. The nerve agents were perhydrolyzed to the respective nontoxic methylphosphonic acids. The relative rapidity of the oxidation and perhydrolysis under these conditions is attributed to the microenvironment of the micropores. Apparently, the reactions are favored due to basic sites on the carbon surface. Our findings suggest a potential environmentally friendly route for decontamination of adsorbed CWAs, using H2O2 without the need of cosolvents or activators.

  10. Decontamination of chemical and biological warfare (CBW) agents using an atmospheric pressure plasma jet (APPJ)

    International Nuclear Information System (INIS)

    Herrmann, H.W.; Henins, I.; Park, J.; Selwyn, G.S.

    1999-01-01

    The atmospheric pressure plasma jet (APPJ) [A. Schuetze et al., IEEE Trans. Plasma Sci. 26, 1685 (1998)] is a nonthermal, high pressure, uniform glow plasma discharge that produces a high velocity effluent stream of highly reactive chemical species. The discharge operates on a feedstock gas (e.g., He/O 2 /H 2 O), which flows between an outer, grounded, cylindrical electrode and an inner, coaxial electrode powered at 13.56 MHz rf. While passing through the plasma, the feedgas becomes excited, dissociated or ionized by electron impact. Once the gas exits the discharge volume, ions and electrons are rapidly lost by recombination, but the fast-flowing effluent still contains neutral metastable species (e.g., O 2 * , He * ) and radicals (e.g., O, OH). This reactive effluent has been shown to be an effective neutralizer of surrogates for anthrax spores and mustard blister agent. Unlike conventional wet decontamination methods, the plasma effluent does not cause corrosion and it does not destroy wiring, electronics, or most plastics, making it highly suitable for decontamination of sensitive equipment and interior spaces. Furthermore, the reactive species in the effluent rapidly degrade into harmless products leaving no lingering residue or harmful by-products. copyright 1999 American Institute of Physics

  11. Skin decontamination

    International Nuclear Information System (INIS)

    Moehrle, G.

    1975-01-01

    A general survey of skin decontamination is given. The success of every decontamination treatments depends mainly on the speed, but also on the care, with which the action is taken. The best way to remove the skin contaminants is thorough washing under lukewarm running water with mild soap and a soft brush. This washing is to be repeated several times for a period of several minutes. If results are not satisfactory, light duty detergents and wetting agents available commercially may also be used. Some solutions which have proved useful are mentioned. The decontamination solutions are best used in the order given. When one has no satisfactory decontamination effect, the next one is to be used. If necessary, these agents must be used several times in the stated order as long as this does not involve too much strain for the skin. All the decontamination measures mentioned refer, of course, to intact healthy skin. After decontamination has been completed, the skin should be treated with a protective cream

  12. Decontamination barrier on TMI-2 leadscrew

    International Nuclear Information System (INIS)

    Baston, V.F.; Hofstetter, K.J.; Bain, G.M.; Haynerg, G.O.

    1985-01-01

    The first major component removed from the TMI-2 Reactor Vessel that has had extensive analytical examination (i.e. radiochemical, metallography, surface chemical analyses, etc.) is the H-8 leadscrew. These analyses indicate adherent cesium activity that is important to the decontamination efforts for TMI-2

  13. Locus-specific microemulsion catalysts for sulfur mustard (HD) chemical warfare agent decontamination.

    Science.gov (United States)

    Fallis, Ian A; Griffiths, Peter C; Cosgrove, Terence; Dreiss, Cecile A; Govan, Norman; Heenan, Richard K; Holden, Ian; Jenkins, Robert L; Mitchell, Stephen J; Notman, Stuart; Platts, Jamie A; Riches, James; Tatchell, Thomas

    2009-07-22

    The rates of catalytic oxidative decontamination of the chemical warfare agent (CWA) sulfur mustard (HD, bis(2-chlororethyl) sulfide) and a range (chloroethyl) sulfide simulants of variable lipophilicity have been examined using a hydrogen peroxide-based microemulsion system. SANS (small-angle neutron scattering), SAXS (small-angle X-ray scattering), PGSE-NMR (pulsed-gradient spin-echo NMR), fluorescence quenching, and electrospray mass spectroscopy (ESI-MS) were implemented to examine the distribution of HD, its simulants, and their oxidation/hydrolysis products in a model oil-in-water microemulsion. These measurements not only present a means of interpreting decontamination rates but also a rationale for the design of oxidation catalysts for these toxic materials. Here we show that by localizing manganese-Schiff base catalysts at the oil droplet-water interface or within the droplet core, a range of (chloroethyl) sulfides, including HD, spanning some 7 orders of octanol-water partition coefficient (K(ow)), may be oxidized with equal efficacy using dilute (5 wt. % of aqueous phase) hydrogen peroxide as a noncorrosive, environmentally benign oxidant (e.g., t(1/2) (HD) approximately 18 s, (2-chloroethyl phenyl sulfide, C(6)H(5)SCH(2)CH(2)Cl) approximately 15 s, (thiodiglycol, S(CH(2)CH(2)OH)(2)) approximately 19 s {20 degrees C}). Our observations demonstrate that by programming catalyst lipophilicity to colocalize catalyst and substrate, the inherent compartmentalization of the microemulsion can be exploited to achieve enhanced rates of reaction or to exert control over product selectivity. A combination of SANS, ESI-MS and fluorescence quenching measurements indicate that the enhanced catalytic activity is due to the locus of the catalyst and not a result of partial hydrolysis of the substrate.

  14. [Decontamination of organophosphorus compounds: Towards new alternatives].

    Science.gov (United States)

    Poirier, L; Jacquet, P; Elias, M; Daudé, D; Chabrière, E

    2017-05-01

    Organophosphorus coumpounds (OP) are toxic chemicals mainly used for agricultural purpose such as insecticides and were also developed and used as warfare nerve agents. OP are inhibitors of acetylcholinesterase, a key enzyme involved in the regulation of the central nervous system. Chemical, physical and biological approaches have been considered to decontaminate OP. This review summarizes the current and emerging strategies that are investigated to tackle this issue with a special emphasis on enzymatic remediation methods. During the last decade, many studies have been dedicated to the development of biocatalysts for OP removal. Among these, recent reports have pointed out the promising enzyme SsoPox isolated from the archaea Sulfolobus solfataricus. Considering both its intrinsic stability and activity, this hyperthermostable enzyme is highly appealing for the decontamination of OP. Copyright © 2017 Académie Nationale de Pharmacie. All rights reserved.

  15. Technical report on natural evaporation system for radioactive liquid waste treatment arising from TRIGA research reactors' decontamination and decommissioning activities

    International Nuclear Information System (INIS)

    Moon, J. S.; Jung, K. J.; Baek, S. T.; Jung, U. S.; Park, S. K.; Jung, K. H.

    1999-01-01

    This technical report described that radioactive liquid waste treatment for dismantling/decontamination of TRIGA Mark research reactor in Seoul. That is, we try safety treatment of operation radioactive liquid waste during of operating TRIGA Mark research reactor and dismantling radioactive liquid waste during R and D of research reactor hereafter, and by utilizing of new natural evaporation facility with describing design criteria of new natural evaporation facility. Therefore, this technical report described the quantity of present radioactive liquid waste and dismantling radioactive liquid waste hereafter, analysis the status of radial-rays/radioactivity, and also treatment method of this radioactive liquid waste. Also, we derived the method that the safeguard of outskirts environment and the cost down of radioactive liquid waste treatment by minimize of the radioactive liquid waste quantities, through-out design/operation of new natural evaporation facility for treatment of operation radioactive liquid waste and dismantling radioactive liquid waste. (author). 6 refs., 12 tabs., 5 figs

  16. Aqueous media treatment and decontamination of hazardous chemical and biological substances by contact plasma

    International Nuclear Information System (INIS)

    Pivovarov, A.; Kravchenko, A.; Kublanovsky, V.

    2009-01-01

    Usage of non-equilibrium contact plasma for processes of decontamination and neutralization in conditions of manifestation of chemical, biological and radiation terrorism takes on special significance due to portability of equipment and its mobility in places where toxic liquid media hazardous for people's health are located. Processes of decontamination of aqueous media, seminated with pathogenic microorganisms and viruses, treatment of water containing toxic heavy metals, cyanides, surface-active substances, and heavy radioactive elements, are investigated. Examples of activation processes in infected water and toxic aqueous solutions present convincing evidence of the way, how new quality technological approach for achievement of high enough degree of the said media treatment is used in each specific case. Among new properties of water activated as a result of action of non-equilibrium contact plasma, it is necessary to mention presence of cluster structure, confirmed by well-known spectral and physical-chemical methods, presence of peroxide compounds, active particles and radicals. Anti-microbial activity which is displayed under action of plasma in aqueous media (chemically pure water, drinking water, aqueous solutions of sodium chloride, potassium iodide, as well as other inorganic compounds) towards wide range of pathogenic and conventionally pathogenic microorganisms allows use them as reliable, accessible and low-cost preparations for increasing the degree of safety of food products. Combination of such processes with known methods of filtration and ultra-filtration gives an efficient and available complex capable of withstanding any threats, which may arise for population and living organisms. Present-day level of machine-building, electrical engineering, and electronics allows predict creation of industrial plasma installations, adapted to conditions of various terrorist threats, with minimized power consumption and optimized technological parameters

  17. Aqueous media treatment and decontamination of hazardous chemical and biological substances by contact plasma

    Energy Technology Data Exchange (ETDEWEB)

    Pivovarov, A; Kravchenko, A [Ukrainian State University of Chemical Engineering, Dnepropetrovsk (Ukraine); Kublanovsky, V [V. I. Vernadsky Institute of General and Inorganic Chemistry of National Academy of Science, Kiev (Ukraine)

    2009-07-01

    Usage of non-equilibrium contact plasma for processes of decontamination and neutralization in conditions of manifestation of chemical, biological and radiation terrorism takes on special significance due to portability of equipment and its mobility in places where toxic liquid media hazardous for people's health are located. Processes of decontamination of aqueous media, seminated with pathogenic microorganisms and viruses, treatment of water containing toxic heavy metals, cyanides, surface-active substances, and heavy radioactive elements, are investigated. Examples of activation processes in infected water and toxic aqueous solutions present convincing evidence of the way, how new quality technological approach for achievement of high enough degree of the said media treatment is used in each specific case. Among new properties of water activated as a result of action of non-equilibrium contact plasma, it is necessary to mention presence of cluster structure, confirmed by well-known spectral and physical-chemical methods, presence of peroxide compounds, active particles and radicals. Anti-microbial activity which is displayed under action of plasma in aqueous media (chemically pure water, drinking water, aqueous solutions of sodium chloride, potassium iodide, as well as other inorganic compounds) towards wide range of pathogenic and conventionally pathogenic microorganisms allows use them as reliable, accessible and low-cost preparations for increasing the degree of safety of food products. Combination of such processes with known methods of filtration and ultra-filtration gives an efficient and available complex capable of withstanding any threats, which may arise for population and living organisms. Present-day level of machine-building, electrical engineering, and electronics allows predict creation of industrial plasma installations, adapted to conditions of various terrorist threats, with minimized power consumption and optimized technological parameters

  18. Decontamination and renovation of the Master/Slave Manipulator Repair Shop and the Chemical Crane Room at the West Valley Demonstration Project. Final topical report, June 1982-June 1983

    International Nuclear Information System (INIS)

    Phillips, E.C.; Golden, M.P.

    1986-01-01

    This report describes the decontamination and renovation of the Master/Slave Manipulator Repair Shop (MSMRS) and the Chemical Crane Room (CCR) at the WVDP from radioactively contaminated conditions to essentially shirt sleeve environments. In both cases, subsequent use recontaminated the rooms. Before decontamination, general exposure rates as high as 20 mrad/hr and surface contamination as high as 10 5 dpm/100 cm 2 were measured in the MSMRS, while general exposure rates in the CCR were 50 to 100 mrad/hr with hot spots as high as 2000 mrad/hr. Smearable levels on the floor in each room were in the range of 10 5 to 10 6 dpm per 100/cm 2 . Respiratory protection was mandatory for entry into the CCR. The MSMRS, located at the north end of the Process Building on ground elevation, is needed for the refurbishment of plant manipulators and other equipment. The MSMRS has been decontaminated and renovated as follows: all tools, equipment and furnishings were removed, the walls were stripped and repainted, and the contaminated concrete floor was removed and disposal of as low-level waste. A new concrete floor was poured and a stainless steel liner covering the entire floor and extending 45.7 cm up the walls was added to provide the WVDP with a shop facility that can be easily decontaminated. Decontamination of the MSMRS has been completed and the facility is available for service. The CCR, located at the north end of the Chemical Process Cell (CPC) is for the storage and servicing of two bridge cranes used in the CPC. Decontamination and exposure reduction in the CCR has been completed using vacuum cleaning, damp wipe down, and surface grinding followed by shielding and painting

  19. Decontamination

    International Nuclear Information System (INIS)

    Montford, B.

    1975-01-01

    Development of special techniques has permitted the use of mild decontamination processes for the CANDU type reactor primary coolant circuit, overcoming many of the problems associated with conventional decontamination processes, which use strong, acidic reagents. (Author)

  20. Strippable gel for decontamination of contaminated metallic surfaces

    International Nuclear Information System (INIS)

    Banerjee, D.; Sandhya, U.; Khot, S.A.; Srinivas, C.; Wattal, P.K.

    2013-01-01

    Periodic decontamination of radioactive laboratories including fume hoods, glove boxes and all surfaces used for handling, processing and transporting radioactive materials is mandatory in all nuclear installations as this reduces spread of contamination and decreases total man rem exposure. Conventionally, chemical decontaminating agents or surfactant solutions are used for this purpose. However, this approach leads to generation of large volume of secondary radioactive waste. The use of strippable gel is an attractive alternative with low secondary waste generation particularly where removal of loose or weakly fixed contamination is necessary and also when the decontaminated material are to be reused, for e.g. decontamination of fume hoods, glove boxes, transport casks, spent fuel storage racks, control rod drive transport containers etc. Literature on gel formulations is scarce and mostly in the patent form. The sustained effort on gel formulation development has resulted in a basic gel formulation. The gel is a highly viscous water-based organic polymer, particularly suitable for application on vertical surfaces including difficult to reach metallic surfaces of complex geometry and not just limited to horizontal surfaces. The gel can be easily applied on contaminated surfaces by brushing or spraying. Curing of the gel is complete within 16-24 hours under ambient conditions and can then be removed by peeling as a dry sheet. While curing, the contaminants are trapped in gel either physically or chemically depending upon the nature of the contaminant. Salient features of cured gel include that it is water soluble and can be disposed off after immobilization in cement. Decontamination performance of the gel was initially evaluated by applying it on SS planchettes contaminated with known amount of radionuclides such as Cs(I), Co(II) and Ce(III). The measured decontamination factor was found to be in the range of 50-500, lowest for Ce(III) and highest for Co

  1. Cold plasma decontamination using flexible jet arrays

    Science.gov (United States)

    Konesky, Gregory

    2010-04-01

    Arrays of atmospheric discharge cold plasma jets have been used to decontaminate surfaces of a wide range of microorganisms quickly, yet not damage that surface. Its effectiveness in decomposing simulated chemical warfare agents has also been demonstrated, and may also find use in assisting in the cleanup of radiological weapons. Large area jet arrays, with short dwell times, are necessary for practical applications. Realistic situations will also require jet arrays that are flexible to adapt to contoured or irregular surfaces. Various large area jet array prototypes, both planar and flexible, are described, as is the application to atmospheric decontamination.

  2. Decontamination of chemical warfare sulfur mustard agent simulant by ZnO nanoparticles

    Science.gov (United States)

    Sadeghi, Meysam; Yekta, Sina; Ghaedi, Hamed

    2016-07-01

    In this study, zinc oxide nanoparticles (ZnO NPs) have been surveyed to decontaminate the chloroethyl phenyl sulfide as a sulfur mustard agent simulant. Prior to the reaction, ZnO NPs were successfully prepared through sol-gel method in the absence and presence of polyvinyl alcohol (PVA). PVA was utilized as a capping agent to control the agglomeration of the nanoparticles. The formation, morphology, elemental component, and crystalline size of nanoscale ZnO were certified and characterized by SEM/EDX, XRD, and FT-IR techniques. The decontamination (adsorption and destruction) was tracked by the GC-FID analysis, in which the effects of polarity of the media, such as isopropanol, acetone and n-hexane, reaction time intervals from 1 up to 18 h, and different temperatures, including 25, 35, 45, and 55 °C, on the catalytic/decontaminative capability of the surface of ZnO NPs/PVA were investigated and discussed, respectively. Results demonstrated that maximum decontamination (100 %) occurred in n-hexane solvent at 55 °C after 1 h. On the other hand, the obtained results for the acetone and isopropanol solvents were lower than expected. GC-MS chromatograms confirmed the formation of hydroxyl ethyl phenyl sulfide and phenyl vinyl sulfide as the destruction reaction products. Furthermore, these chromatograms proved the role of hydrolysis and elimination mechanisms on the catalyst considering its surface Bronsted and Lewis acid sites. A non-polar solvent aids material transfer to the reactive surface acid sites without blocking these sites.

  3. Mesoporous CuO–ZnO binary metal oxide nanocomposite for decontamination of sulfur mustard

    International Nuclear Information System (INIS)

    Praveen Kumar, J.; Prasad, G.K.; Ramacharyulu, P.V.R.K.; Garg, P.; Ganesan, K.

    2013-01-01

    Mesoporous CuO–ZnO binary metal oxide nanocomposites were studied as sorbent decontaminants against sulfur mustard, a well known chemical warfare agent. They were prepared by precipitation pyrolysis method and characterized by means of X-ray diffraction, transmission electron microscopy, nitrogen adsorption, Fourier transform infrared spectroscopy techniques. Obtained data indicated the presence of mesopores with diameter ranging from 2 to 80 nm and the materials exhibited relatively high surface area 86 m 2 g −1 when compared to the individual metal oxide nanoparticles. Reactive sites of mesoporous CuO–ZnO binary metal oxide nanocomposites were studied by infrared spectroscopy technique using pyridine as a probe molecule. These materials demonstrated superior decontamination properties against sulfur mustard when compared to single component metal oxides and decontaminated it to divinyl sulfide, chloroethyl vinyl sulfide, hemisulfur mustard, etc. - Graphical abstract: Mesoporous CuO–ZnO binary metal oxide nanocomposites were studied as sorbent decontaminants against sulfur mustard, a well known chemical warfare agent. These materials demonstrated superior decontamination properties against sulfur mustard and decontaminated it to divinyl sulfide, chloroethyl vinyl sulfide, hemisulfur mustard, etc. - Highlights: • Preparation of mesoporous CuO–ZnO binary metal oxide nanocomposite. • CuO–ZnO with better surface area was synthesized by precipitation pyrolysis. • Decontamination of HD using mesoporous CuO–ZnO binary metal oxide nanocomposite. • HD decontaminated by elimination and hydrolysis reactions

  4. Mesoporous CuO–ZnO binary metal oxide nanocomposite for decontamination of sulfur mustard

    Energy Technology Data Exchange (ETDEWEB)

    Praveen Kumar, J.; Prasad, G.K., E-mail: gkprasad2001@yahoo.com; Ramacharyulu, P.V.R.K.; Garg, P.; Ganesan, K.

    2013-11-01

    Mesoporous CuO–ZnO binary metal oxide nanocomposites were studied as sorbent decontaminants against sulfur mustard, a well known chemical warfare agent. They were prepared by precipitation pyrolysis method and characterized by means of X-ray diffraction, transmission electron microscopy, nitrogen adsorption, Fourier transform infrared spectroscopy techniques. Obtained data indicated the presence of mesopores with diameter ranging from 2 to 80 nm and the materials exhibited relatively high surface area 86 m{sup 2} g{sup −1} when compared to the individual metal oxide nanoparticles. Reactive sites of mesoporous CuO–ZnO binary metal oxide nanocomposites were studied by infrared spectroscopy technique using pyridine as a probe molecule. These materials demonstrated superior decontamination properties against sulfur mustard when compared to single component metal oxides and decontaminated it to divinyl sulfide, chloroethyl vinyl sulfide, hemisulfur mustard, etc. - Graphical abstract: Mesoporous CuO–ZnO binary metal oxide nanocomposites were studied as sorbent decontaminants against sulfur mustard, a well known chemical warfare agent. These materials demonstrated superior decontamination properties against sulfur mustard and decontaminated it to divinyl sulfide, chloroethyl vinyl sulfide, hemisulfur mustard, etc. - Highlights: • Preparation of mesoporous CuO–ZnO binary metal oxide nanocomposite. • CuO–ZnO with better surface area was synthesized by precipitation pyrolysis. • Decontamination of HD using mesoporous CuO–ZnO binary metal oxide nanocomposite. • HD decontaminated by elimination and hydrolysis reactions.

  5. Safety aspects in decontamination operations: Lessons learned during the decommissioning of a small PWR reactor

    International Nuclear Information System (INIS)

    Klein, M.; Ponnet, M.; Emond, O.

    2002-01-01

    Decontamination operations are generally executed during the decommissioning of nuclear installations for different objectives: decontamination of loops or large pieces to reduce the dose rate inside a contaminated plant or decontamination to minimize the amount of radioactive waste. These decontamination operations raise safety issues such as radiological exposure, classical safety, environmental releases, production and management of secondary waste, management of primary resources, etc. This paper presents the return of experience from decontamination operations performed during the dismantling of the BR3 PWR reactor. The safety issues are discussed for 3 types of decontamination operations: full system decontamination of the primary loop with a chemical process to reduce the dose rate by a factor of 10; thorough decontamination with an aggressive chemical process of dismantled pieces to reach the unconditional clearance values; and thorough decontamination processes with physical processes of metals and of concrete to reach the unconditional clearance values. For the protection of the workers, we must consider the ALARA aspects and the classical safety issues. During the progress of our dismantling operations, the dose rate issue was becoming less important but the classical safety issues were becoming preponderant due to the use of very aggressive techniques. For the protection of the environment, we must take all the precautions to avoid any leakages from the plant and we must use processes which minimize the use of toxic products and which minimize the production of secondary wastes. We therefore promote the use of regenerative processes. (author)

  6. Comparison and Evaluation of Various Tritium Decontamination Techniques and Processes

    International Nuclear Information System (INIS)

    Gentile, C.A.; Langish, S.W.; Skinner, C.H.; Ciebiera, L.P.

    2004-01-01

    In support of fusion energy development, various techniques and processes have been developed over the past two decades for the removal and decontamination of tritium from a variety of items, surfaces, and components. Tritium decontamination, by chemical, physical, mechanical, or a combination of these methods, is driven by two underlying motivational forces. The first of these motivational forces is safety. Safety is paramount to the established culture associated with fusion energy. The second of these motivational forces is cost. In all aspects, less tritium contamination equals lower operational and disposal costs. This paper will discuss and evaluate the various processes employed for tritium removal and decontamination

  7. Comparison and Evaluation of Various Tritium Decontamination Techniques and Processes

    International Nuclear Information System (INIS)

    Gentile, C.A.; Langish, S.W.; Skinner, C.H.; Ciebiera, L.P.

    2005-01-01

    In support of fusion energy development, various techniques and processes have been developed over the past two decades for the removal and decontamination of tritium from a variety of items, surfaces, and components. The motivational force for tritium decontamination by chemical, physical, mechanical, or a combination of these methods, is driven by two underlying forces. The first of these motivational forces is safety. Safety is paramount to the established culture associated with fusion energy. The second of these motivational forces is cost. In all aspects, less tritium contamination equals lower operational and disposal costs. This paper will discuss and evaluate the various processes employed for tritium removal and decontamination

  8. Decontamination of lead by fusion (1962)

    International Nuclear Information System (INIS)

    Boutot, P.; Giachetto, L.; Capitaine, A.

    1962-01-01

    Various attempts to decontaminate using mechanical and chemical methods having given questionable results, a fusion method has been developed. The apparatus consists of a propane-heated oven fitted with a steel crucible of 1 400 kg capacity, with two ventilation systems, and with a vacuum gauge for preventing the diffusion of toxic gases. There are three operational controls : 1. On the samples taken before during and after the operation, 2. On the plugs taken from the ingots, 3. On the ingot itself. The continuous sanitary control is done by a radioactive aerosol recorder and by periodic sampling. This decontamination process will be improved, especially as far as the productivity and the safety precautions are concerned. (authors) [fr

  9. Polymeric compositions for “dry” decontamination of NPP equipment and premises

    International Nuclear Information System (INIS)

    Voronik, N.I.; Toropova, V.V.

    2015-01-01

    In JIPNR – “Sosny” NASB developed decontaminating polymeric compositions based on binder – polyvinyl alcohol solution with active additives such as nitric and borohydrofluoric acids, 1-hydroxyethylidene diphosphonic acid and its salts, detergents and fillers - natural tripoli; tripoli modified by ferrocyanides of nickel and copper; pulverized dolomite modified by manganese oxides, ferrocyanides of nickel and copper; clinoptilolite modified by iron chlorides (III) and calcium sodium phosphate and potassium ferrocyanide; hydrolytic lignin. It is shown that the developed decontaminating polymeric compositions (pastes) possess high decontaminating capacity (FD 102 – 103) and low adhesion to the surfaces of stainless and carbon steels, including painted, plastic, self-leveling floors, teflon-surface. Prolonged leaching method allowed determine the chemical resistance of “dry” decontamination wastes, strength of "1"3"7Cs and "6"0Co fixations in wastes obtained in result of using new decontamination pastes [ru

  10. Low level radioactive liquid waste decontamination by electrochemical way

    International Nuclear Information System (INIS)

    Tronche, E.

    1994-10-01

    As part of the work on decontamination treatments for low level radioactive aqueous liquid wastes, the study of an electro-chemical process has been chosen by the C.E.A. at the Cadarache research centre. The first part of this report describes the main methods used for the decontamination of aqueous solutions. Then an electro-deposition process and an electro-dissolution process are compared on the basis of the decontamination results using genuine radioactive aqueous liquid waste. For ruthenium decontamination, the former process led to very high yields (99.9 percent eliminated). But the elimination of all the other radionuclides (antimony, strontium, cesium, alpha emitters) was only favoured by the latter process (90 percent eliminated). In order to decrease the total radioactivity level of the waste to be treated, we have optimized the electro-dissolution process. That is why the chemical composition of the dissolved anode has been investigated by a mixture experimental design. The radionuclides have been adsorbed on the precipitating products. The separation of the precipitates from the aqueous liquid enabled us to remove the major part of the initial activity. On the overall process some operations have been investigated to minimize waste embedding. Finally, a pilot device (laboratory scale) has been built and tested with genuine radioactive liquid waste. (author). 77 refs., 41 tabs., 55 figs., 4 appendixes

  11. Decontamination of CAGR gas circulator components

    International Nuclear Information System (INIS)

    Rogers, L.N.; Hooper, A.J.

    1985-01-01

    This paper describes the development and full-scale trial of two methods for removal of radioactive contamination on the surfaces of CAGR gas circulator components. The two methods described are a particle impact cleaning (PIC) decontamination technique and an electrochemical technique, 'electro-swabbing', which is based on the principle of decontamination by electro-polishing. In developing these techniques it was necessary to take account of the physical and chemical nature of the surface deposits on the gas circulator components; these were shown to consist of magnetite-type oxide and carbonaceous material. In order to follow the progress of the decontamination it was also necessary to develop a surface sampling technique which was effective and precise under these conditions; an electrochemical technique, employing similar principles to the electro-swabbing process, was developed for this purpose. The full-scale trial of the PIC decontamination technique was carried out on an inlet guide vane (IGV) assembly, this having been identified as the component from the gas circulator which contributes most to the radiation dose accumulated during routine circulator maintenance. The technique was shown to be practically viable and some 99% of the radioactive contamination was readily removed from the treated surfaces with only negligible surface damage being caused. The full-scale trial of the electro-swabbing decontamination technique was carried out on a gas circulator impeller. High decontamination factors were again achieved with ≥ 99% of the radioactive contamination being removed from the treated surfaces. The technique has practical limitations in terms of handling and treatment of waste-arisings. However, the use of specially-designed swabbing electrodes may allow the treatment of constricted geometries inaccessible to techniques such as PIC. The technique is also highly suitable for the treatment of soft-finish materials and of components fabricated from a

  12. AREVA NP decontamination concept for decommissioning. A comprehensive approach based on over 30 years experience

    International Nuclear Information System (INIS)

    Stiepani, Christoph

    2011-01-01

    Decontamination prior to Decommissioning and Dismantlement is imperative. Not only does it provide for minimization of personnel dose exposure but also maximization of the material volume available for free release. Since easier dismantling techniques in lower dose areas can be applied, the licensing process is facilitated and the scheduling and budgeting effort is more reliable. The most internationally accepted approach for Decontamination prior to Decommissioning projects is the Full System Decontamination (FSD). FSD is defined as the chemical decontamination of the primary cooling circuit, in conjunction with the main auxiliary systems. AREVA NP has long-term experience with Full System Decontamination for return to service of operating nuclear power plants as well as for decommissioning after shutdown. Since 1976, AREVA NP has performed over 500 decontamination applications and, from 1986, Decontaminations prior to Decommissioning projects which comprise virtually all NPP designs and plant conditions were performed: NPP designs: HPWR, PWR, and BWR by AREVA, Westinghouse, ABB and GE. Decontaminations performed shortly after final shutdown or several years later, and even after re-opening Safe Enclosure. High Alpha inventory and or low gamma/alpha ratio. Main Coolant chemistry (e.g., with and without Zn injection during operation). Fifteen Decontaminations prior to Decommissioning Projects have been performed successfully to date and the sixteenth FSD is now in the detailed engineering phase and is scheduled to commence late 2010. AREVA NP has developed a fully comprehensive approach for decontamination based on the CORD® (Chemical Oxidation Reduction Decontamination) Family, applied using the in-house designed decontamination equipment AMDA TM (Automatic Modular Decontamination Appliance). Based on the vast experience of AREVA NP in the field of decontamination, the Decontamination Concept for Decommissioning was developed. This concept ensures that the

  13. Decontamination of Hetron Tank from Decominissioning of Phosphate Acid Purification Instalation

    International Nuclear Information System (INIS)

    Sutoto

    2008-01-01

    To decreasing quantity of the contaminated equipment from the nuclear installation decommissioning activity, it can be done by decontamination. Its process must be done by considering of radiation safety so that not dangerous to worker and environment. Effectively method must be chosen so that not generate high of secondary wastes. To primary decontamination of HETRON tank with a chemical method is not effectively to used because its a reinforcement thermoplastic materials. These material has high resistance for chemical compound. Therefore selected methods of physical-mechanical decontamination, that is can to removal of contaminants from the surface by scrubbing and swabbing with used of wet cloth have been tried and effective to decreasing of β/γ radiation rate until about (0.04 - 0.06 mR/h), its value is equal to background rate and the level of α/β radiation activity contamination is about (1.07 - 2.03 Bq/cm 2 ), so that it can be out grouping as radioactive waste. For the equipment of which cannot decontaminated, it grouped as solid radioactive waste and together with secondary waste will be sent to PTLR-BATAN. (author)

  14. Development of Personal Decontamination System Final Report CRADA No. TC-02078-04

    Energy Technology Data Exchange (ETDEWEB)

    Smith, W. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); O' Dell, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-27

    This was a collaborative effort between The Regents of the University of California, Lawrence Livermore National Laboratory (LLNL) and O’Dell Engineering, Ltd. (O’Dell) to develop an improved low-cost personal decontamination system for Toxic Industrial Chemicals (TICs) and chemical agents. The significant change to the project was that COTS (Commercial Off-the Shelf Components) were identified that performed as well, or better than, the proprietary materials created and tested as part of this CRADA. These COTS components were combined to create a new LPDS (low-cost personal decontamination system) that met all specifications.

  15. Decontamination and size reduction of plutonium contaminated process exhaust ductwork and glove boxes

    International Nuclear Information System (INIS)

    LaFrate, P.; Elliott, J.; Valasquez, M.

    1996-01-01

    The Los Alamos National Laboratory (LANL) Decommissioning Program has decontaminated and demolished two filter plenum buildings at Technical Area 21 (TA-21). During the project a former hot cell was retrofitted to perform decontamination and size reduction of highly Pu contaminated process exhaust (1,100 ft) and gloveboxes. Pu-238/239 concentrations were as high a 1 Ci per linear foot and averaged approximately 1 mCi/ft. The Project decontamination objective was to reduce the plutonium contamination on surfaces below transuranic levels. If possible, metal surfaces were decontaminated further to meet Science and Ecology Group (SEG) waste classification guidelines to enable the metal to be recycled at their facility in oak Ridge, Tennessee. Project surface contamination acceptance criteria for low-level radioactive waste (LLRW), transuranic waste, and SEG waste acceptance criteria will be presented. Ninety percent of all radioactive waste for the project was characterized as LLRW. Twenty percent of this material was shipped to SEG. Process exhaust and glove boxes were brought to the project decontamination area, an old hot cell in Building 4 North. This paper focuses on process exhaust and glovebox decontamination methodology, size reduction techniques, waste characterization, airborne contamination monitoring, engineering controls, worker protection, lessons learned, and waste minimization. Decontamination objectives are discussed in detail

  16. Role reductants in dilute chemical decontamination formulations

    Energy Technology Data Exchange (ETDEWEB)

    Ranganathan, S. [Univ. of New Brunswick (Canada). Dept. of Chemical Engineering; Srinivasan, M.P.; Narasimhan, S.V. [Bhabha Atomic Research Centre (BARC), Trombay, Mumbai (India). Water and Steam Chemistry Lab.; Raghavan, P.S. [Madras Christian Coll., Chennai (India); Gopalan, R. [Madras Christian Coll., Chennai (India). Dept. of Chemistry

    2004-10-01

    Iron(III) oxides are the major corrosion products formed in boiling water reactors. The iron(III) oxides are of two types, namely hematite ({alpha}-Fe{sub 2}O{sub 3}) and maghemite ({gamma}-Fe{sub 2}O{sub 3}). The dissolution of these oxides is in no way simple because of the labile nature of the Fe(III)-O bond towards the chelants. The leaching of metal ions is partially controlled by reductive dissolution. In order to understand the role of the reductant, it is essential to study the dissolution behaviour of a system like Fe{sub 2}O{sub 3}, which does not contain any Fe{sup 2+} in the crystal lattice. The present study was carried out with {gamma}-Fe{sub 2}O{sub 3} and dilute chemical decontamination (DCD) formulations containing ascorbic acid and citric acid with the addition of Fe(II)-L as a reductant. The chelants used for the dissolution process were nitrilotriacetic acid, 2,6-pyridinedicorboxylic acid and ethylenediaminetetraacetic acid. The {gamma}-Fe{sub 2}O{sub 3} was chosen since the earlier studies revealed that the dissolution kinetics of {alpha}-Fe{sub 2}O{sub 3} is slow and it is difficult to dissolve even by strong complexing agents, whereas {gamma}-Fe{sub 2}O{sub 3} dissolution is comparatively easier. This is due to the structural difference between these two oxides. The studies also revealed that the dissolution was partly influenced by the nature of the chelating agents but mainly controlled by the power of the reductants used in the formulation. The dissolution behaviour of {gamma}-Fe{sub 2}O{sub 3} under various experimental conditions is discussed and compared with that of magnetite in order to arrive at a suitable mechanism for the dissolution of iron oxides and emphasize the role of reductants in DCD formulations. (orig.)

  17. Steam Generator Group Project. Task 6. Channel head decontamination

    International Nuclear Information System (INIS)

    Allen, R.P.; Clark, R.L.; Reece, W.D.

    1984-08-01

    The Steam Generator Group Project utilizes a retired-from-service pressurized-water-reactor steam generator as a test bed and source of specimens for research. An important preparatory step to primary side research activities was reduction of the radiation field in the steam generator channel head. This task report describes the channel head decontamination activities. Though not a programmatic research objective it was judged beneficial to explore the use of dilute reagent chemical decontamination techniques. These techniques presented potential for reduced personnel exposure and reduced secondary radwaste generation, over currently used abrasive blasting techniques. Two techniques with extensive laboratory research and vendors prepared to offer commercial application were tested, one on either side of the channel head. As indicated in the report, both techniques accomplished similar decontamination objectives. Neither technique damaged the generator channel head or tubing materials, as applied. This report provides details of the decontamination operations. Application system and operating conditions are described

  18. UK fast reactor components. Sodium removal decontamination and requalification

    International Nuclear Information System (INIS)

    Donaldson, D.M.; Bray, J.A.; Newson, I.H.

    1978-01-01

    Extensive experience gained at the U.K.A.E.A. Dounreay Nuclear Power Development Establishment is being applied to form the basis of the plant to be provided for sodium removal, decontamination, and requalification of components in future commercial fast reactors. In the first part of a three part paper, the factors to be taken into account, showing the UK philosophy and approach to maintenance and repair operations are discussed. In the second part, PFR facilities for sodium removal and decontamination are described and some examples are given of cleaning components such as pumps, charge machine, cold trap baskets, and steam generator units. Similar facilities at DFR are briefly described. In the third part of the paper a short description is given of the Harwell mass transfer loop, currently used to study the deposition of activated stainless steel corrosion products. Decontamination method for pipework specimens cut from the loop are described and results of first screening tests of various chemical decontaminants are presented. (U.K.)

  19. Decontamination techniques for buildings, structures and equipment

    International Nuclear Information System (INIS)

    Esposito, M.P.; Clark, R.

    1987-01-01

    This book provides information on pollution protection. It describes decontamination process for such pertinent pollutants as asbestos, acids, explosives, cyanides, low level radiation, pesticides, P.C.B.'s and hazardous organic chemicals. The discussions include advantages, disadvantages, cost, effectiveness of the procedures and waste disposal

  20. The International Atomic Energy Agency's program on decontamination and decommissioning

    International Nuclear Information System (INIS)

    Feraday, M.A.

    1989-01-01

    The International Atomic energy Agency (IAEA) is developing an integrated information base that will systematically cover the technical, regulatory, radiation protection, planning, and economic aspects related to the decontamination and decommissioning (D/D) of nuclear facilities. The object of this program is to assist member states in developing the required expertise, equipment, and programs so that they can decommission their nuclear facilities in a safe, timely, and cost-effective manner. In addition to providing information, the IAEA encourages research and provides technical assistance in the form of expert missions, equipment design and procurement, etc., to assist member states in implementing their D/D programs. The technology contained in some recent IAEA reports is reviewed, including the decontamination, segmentation, and demolition of concrete and steel; the recycle/reuse of components from decommissioning; and the reduction of occupational exposures in D/D and the regulatory process in decommissioning. The IAEA's future program is briefly reviewed

  1. Oxidation of Ce(III) in Foam Decontaminant by Ozone

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Chong Hun; Yoon, I. H.; Choi, W. K.; Moon, J. K.; Yang, H. B. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, J. S. [Gachon University, Seongnam (Korea, Republic of)

    2016-10-15

    A nanoparticle-based foam decontaminant is composed of a surfactant and nanoparticles for the generation and maintenance of foam, and a chemical decontamination agent made of Ce(IV) dissolved in nitric acid. Ce(IV) will be reduced to Ce(III) through the decontamination process. Oxidizing cerium(III) can be reused as a decontamination agent, Ce(IV). Oxidation treatment technology by ozone uses its strong oxidizing power. It can be regarded as an environmentally friendly process, because ozone cannot be stored and transported like other industrial gases (because it quickly decays into diatomic oxygen) and must therefore be produced on site, and used ozone can decompose immediately. The ozonation treatment of Ce(III) in foam decontaminant containing a surfactant is necessary for the effective regeneration of Ce(III). Thus, the present study was undertaken to determine the optimal conditions for ozonation treatment in the regeneration of Ce(III) into Ce(IV) in the nanoparticle-based foam decontaminant containing surfactant. This study was undertaken to determine the optimal conditions for ozonation treatment in the regeneration of Ce(III) to Ce(IV) in nanoparticle-based foam decontaminant containing a TBS surfactant. The oxidation conversion rate of Ce(III) was increased with an increase in the flow rate of the gas mixture and ozone injection amount. The oxidation time required for the 100% oxidation conversion of Ce(III) to Ce(IV) at a specific ozone injection amount can be predicted from these experimental data.

  2. Oxidation of Ce(III) in Foam Decontaminant by Ozone

    International Nuclear Information System (INIS)

    Jung, Chong Hun; Yoon, I. H.; Choi, W. K.; Moon, J. K.; Yang, H. B.; Lee, J. S.

    2016-01-01

    A nanoparticle-based foam decontaminant is composed of a surfactant and nanoparticles for the generation and maintenance of foam, and a chemical decontamination agent made of Ce(IV) dissolved in nitric acid. Ce(IV) will be reduced to Ce(III) through the decontamination process. Oxidizing cerium(III) can be reused as a decontamination agent, Ce(IV). Oxidation treatment technology by ozone uses its strong oxidizing power. It can be regarded as an environmentally friendly process, because ozone cannot be stored and transported like other industrial gases (because it quickly decays into diatomic oxygen) and must therefore be produced on site, and used ozone can decompose immediately. The ozonation treatment of Ce(III) in foam decontaminant containing a surfactant is necessary for the effective regeneration of Ce(III). Thus, the present study was undertaken to determine the optimal conditions for ozonation treatment in the regeneration of Ce(III) into Ce(IV) in the nanoparticle-based foam decontaminant containing surfactant. This study was undertaken to determine the optimal conditions for ozonation treatment in the regeneration of Ce(III) to Ce(IV) in nanoparticle-based foam decontaminant containing a TBS surfactant. The oxidation conversion rate of Ce(III) was increased with an increase in the flow rate of the gas mixture and ozone injection amount. The oxidation time required for the 100% oxidation conversion of Ce(III) to Ce(IV) at a specific ozone injection amount can be predicted from these experimental data

  3. Post-accident TMI-2 (Three Mile Island-Unit 2) decontamination and defueling

    International Nuclear Information System (INIS)

    Hofstetter, K.J.; Baston, V.F.

    1986-01-01

    Following the accident at Three Mile Island-Unit 2 (TMI-2), a substantial quantity of fission products was distributed throughout various plant systems and areas. The control of further migration of these radionuclides was accomplished by various physical and chemical means. The decontamination and defueling activities have proceeded within specific regulatory, administrative, and hardware restrictions. A summary of the post-accident status of the plant systems, the decontamination methods used, and the end-point criteria will be discussed. The hardware installed or utilized to perform the cleanup operations will be described. The methods and progress of defueling will also be presented. The development of detailed water chemistry requirements and their effects on systems and decontamination efforts are discussed. The planning, scheduling, and performance of specific recovery tasks are presented along with a general overview of water and chemical management at TMI-2

  4. Decontamination as a precursor to decommissioning. Status report Task 2: process evaluation

    International Nuclear Information System (INIS)

    Divine, J.R.; Woodruff, E.M.; McPartland, S.A.; Zima, G.E.

    1983-05-01

    As part of the US Nuclear Regulatory Commission's program to reduce occupational exposure and waste volumes, the Pacific Northwest Laboratory is studying decontamination as a precursor to decommissioning. Eleven processes or solvents were examined for their behavior in decontaminating BWR carbon steel samples. The solvents included NS-1, a proprietary solvent of Dow Chemical Corporation, designed for BWR use, and AP-Citrox, a well-known, two-step process designed for PWR stainless steel; it was used to provide a reference for later comparison to other systems and processes. The decontamination factors observed in the tests performed in a small laboratory scale recirculating loop ranged from about 1 (no effect) to 222 (about 99.6% of the initial activity removed. Coordinated corrosion measurements were made using twelve chemical solvents and eight metal alloys found in a range of reactor types

  5. Some aspects of radioactive contamination and decontamination of the Chernobyl' NPP accident zone territory

    International Nuclear Information System (INIS)

    Samojlenko, Yu.N.; Nad''yarnykh, G.V.; Teplitskij, A.L.; Shilin, S.A.

    1989-01-01

    Data are presented on the radioactive contamination of the 30-km zone, on the radionuclide (RN) distribution in soils and on the RN migration in grounds. During 1986-1988 were tested over 20 techniques for territory decontamination and were found out the most optimal ones. The first stage of decontamination was removal of an upper contaminated soil layer. The second stage was prolonged chemical fixation of dusting decontaminated soil areas. 3 tabs

  6. Commercial Cleaning Products for Chemical Decontamination: A Scoping Study

    Science.gov (United States)

    2014-05-01

    and may injure human skin without dilution), although this approach is less favoured in a mass casualty decontamination situation than soap and water...commercial cleaning products, full strength K-O-K® liquid bleach (5.25% aqueous solution of NaOCl), dish-washing detergent Cascade® with Extra...Bleach Action Gel, OxiClean® Versatile Stain Remover Powder, and ZEP® Industrial Purple liquid cleaner (proprietary caustic cleaner containing

  7. Surface decontamination

    International Nuclear Information System (INIS)

    Silva, S. da; Teixeira, M.V.

    1986-06-01

    The general methods of surface decontamination used in laboratory and others nuclear installations areas, as well as the procedures for handling radioactive materials and surfaces of work are presented. Some methods for decontamination of body external parts are mentioned. The medical supervision and assistance are required for internal or external contamination involving or not lesion in persons. From this medical radiation protection decontamination procedures are determined. (M.C.K.) [pt

  8. Chemical surety material decontamination and decommissioning of Los Alamos National Laboratory Chemical Surety Material Laboratory area TA-3, building SM-29, room 4009

    International Nuclear Information System (INIS)

    Moore, T.E.; Smith, J.M.

    1994-04-01

    From 1982 through 1987, Los Alamos National Laboratory (LANL) performed surety laboratory operations for the U.S. Army Medical Research and Development Command (MRDC). Room 4009 in building SM-29, TA-3, was used as the laboratory for work with the following chemical surety material (CSM) agents: sarin (GB), soman (GD), lewisite (L), and distilled mustard (HD) radio-labelled with H 3 or C 14 . The work was confined to three CSM-certified fume hoods, located in room 4009 (see diagram in Appendix C). The laboratory ceased all active operations during the late 1986 and early 1987 period. From 1987 until 1993 the laboratory was secured and the ventilation system continued to operate. During late 1992, the decision was made to utilize this laboratory space for other operations, thus a decision was made to dismantle and reconfigure this room. LANL sub-contracted Battelle Memorial Institute (BMI) to draw upon the CSM experience of the technical staff from the Hazardous Materials Research Facility (HMRF) to assist in developing a decontamination and decommissioning plan. BMI was subcontracted to devise a CSM safety training course, and a sampling and air monitoring plan for CSM material to ensure personnel safety during all disassembly operations. LANL subcontracted Johnson Controls personnel to perform all disassembly operations. Beginning in early 1993 BMI personnel from the HMRF visited the laboratory to develop both the safety plan and the sample and air monitoring plan. Execution of that plan began in September 1993 and was completed in January 1994

  9. Chemical surety material decontamination and decommissioning of Los Alamos National Laboratory Chemical Surety Material Laboratory area TA-3, building SM-29, room 4009

    Energy Technology Data Exchange (ETDEWEB)

    Moore, T.E.; Smith, J.M.

    1994-04-01

    From 1982 through 1987, Los Alamos National Laboratory (LANL) performed surety laboratory operations for the U.S. Army Medical Research and Development Command (MRDC). Room 4009 in building SM-29, TA-3, was used as the laboratory for work with the following chemical surety material (CSM) agents: sarin (GB), soman (GD), lewisite (L), and distilled mustard (HD) radio-labelled with H{sup 3} or C{sup 14}. The work was confined to three CSM-certified fume hoods, located in room 4009 (see diagram in Appendix C). The laboratory ceased all active operations during the late 1986 and early 1987 period. From 1987 until 1993 the laboratory was secured and the ventilation system continued to operate. During late 1992, the decision was made to utilize this laboratory space for other operations, thus a decision was made to dismantle and reconfigure this room. LANL sub-contracted Battelle Memorial Institute (BMI) to draw upon the CSM experience of the technical staff from the Hazardous Materials Research Facility (HMRF) to assist in developing a decontamination and decommissioning plan. BMI was subcontracted to devise a CSM safety training course, and a sampling and air monitoring plan for CSM material to ensure personnel safety during all disassembly operations. LANL subcontracted Johnson Controls personnel to perform all disassembly operations. Beginning in early 1993 BMI personnel from the HMRF visited the laboratory to develop both the safety plan and the sample and air monitoring plan. Execution of that plan began in September 1993 and was completed in January 1994.

  10. Selection of technical and economic purification system wastewater, applying the assessment of the water decontamination; Seleccion tecnico-economica del sistema de depuracion de aguas residuales

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Miranda, J. P.

    2009-07-01

    The decontamination in water bodies can be realised among others by treatments at the end of the tube. For it is necessary to apply to a methodology or procedure for economic the technical selection of alternatives for the handling or treatments of liquid residues at the end of the tube. Calculation example, a study of case (municipality) in the Savannah of Bogota was developed (Colombia), where the technical valuation of the best alternative of treatment at the end of the tube was observed that stops the case of the analysis, the optimal system is the percolating filter from the plant of comparison of removal efficiencies, costs of investment, operation and maintenance, as well as the specific qualitative valuation of each alternative. (Author) 27 refs.

  11. Radioisotope decontamination of X-ray detector. Photostimulable phosphor plate

    International Nuclear Information System (INIS)

    Onuma, Yoji; Hayashi, Michiko; Hayashi, Hiroaki; Nishihara, Sadamitsu

    2012-01-01

    We tried to remove contamination of radioisotope (RI) for an X-ray detector (photostimulable phosphor plate; IP) and verified that our procedure suggested by Nishihara et al. was effective for decontamination. The procedure was as follows. First, the IP was kept for approximately twelve hours, and then it was processed [image (A)] as well as a clinical processing mode. Second, using a wet-type chemical wiper, we scavenged the IP to remove the adhered RI on its surface. Then, once again, the IP was kept for approximately fifteen hours and processed [image (B)] in order to check an effect of decontamination. Finally, the two images of (A) and (B) were analyzed using ImageJ, which can be downloaded as a free software, and a percentage of removal was calculated. The procedure was applied to two IPs using the Fuji computed tomography (FCR) 5501 plus. In the present case, the percentage of removal was approximately 96%. The removed radioisotopes in the chemical wipers were analyzed by Ge detector. Then, 134 Cs and 137 Cs were found with activities of 2.9 4.3 Bq and 3.5 5.2 Bq, respectively. For three months after that, we cannot see black spots on the IPs owing to the contamination of the RI and there are no defects caused by decontamination using a wet-type chemical wiper. (author)

  12. Study of the characterization and formulation of the decontamination gels

    Energy Technology Data Exchange (ETDEWEB)

    Park, Youn Bong; Bang, In Bae; Bae, Bong Moon; Oh, Gyu Hwan [Chungnam National University, Daejeon (Korea, Republic of)

    2011-04-15

    To develop a chemical gel decontamination technology for a removal of non-fixed contaminants during the maintenance and decommissioning works of high radiation hot cells which have been used for a recycling or treatment of spent fuels we have prepare gels with CAB-O-SIL M-5 or Aerosil 380 as viscosifier and some non-ionic surfactants such as diethylene glycol hexyl ether, triethylene glycol dodecyl ether, polyethylene glycol 600, and triethylene glycol butyl ether. Surfactants are playing important roles in manipulating the properties of decontamination the gels. We have found the CAB-O-SIL with triethylene glycol butyl ether and Aerosil with triethylene glycol dodecyl ether systems promising for the decontamination work

  13. Decontamination before dismantling a fast breeder reactor primary cooling system

    International Nuclear Information System (INIS)

    Costes, J.R.; Antoine, P.; Gauchon, J.P.

    1997-01-01

    The large-scale decontamination of FBR sodium loops is a novel task, as only a limited number of laboratory-scale results are available to date. The principal objective of this work is to develop a suitable decontamination procedure for application to the primary loops of the RAPSODIE fast breeder reactor as part of decommissioning to Stage 2. After disconnecting the piping from the main vessel, the pipes were treated by circulating chemical solutions and the vessels by spraying. The dose rate in the areas to be dismantled was divided by ten. A decontamination factor of about 300 was obtained, and should allow austenitic steel parts to be melted in special furnaces for unrestricted release. (author)

  14. Study of the characterization and formulation of the decontamination gels

    International Nuclear Information System (INIS)

    Park, Youn Bong; Bang, In Bae; Bae, Bong Moon; Oh, Gyu Hwan

    2011-04-01

    To develop a chemical gel decontamination technology for a removal of non-fixed contaminants during the maintenance and decommissioning works of high radiation hot cells which have been used for a recycling or treatment of spent fuels we have prepare gels with CAB-O-SIL M-5 or Aerosil 380 as viscosifier and some non-ionic surfactants such as diethylene glycol hexyl ether, triethylene glycol dodecyl ether, polyethylene glycol 600, and triethylene glycol butyl ether. Surfactants are playing important roles in manipulating the properties of decontamination the gels. We have found the CAB-O-SIL with triethylene glycol butyl ether and Aerosil with triethylene glycol dodecyl ether systems promising for the decontamination work

  15. New technologies for PCB [polychlorinated biphenyl] decontamination

    International Nuclear Information System (INIS)

    Webber, I.

    1993-01-01

    Polychlorinated biphenyls (PCB) were mixed with chlorobenzenes to reduce viscosity and provide for both electrical insulation and convective heat transfers. These mixtures were known as askarels, and ca 99.8% of PCBs used in electrical applications are contained in askarel-filled transformers and capacitors. It is estimated that there are ca 180 million gal of PCB-contaminated oil distributed through over 3 million transformers in the USA. Technology used for decontaminating these transformers depends on the concentration of the PCB contamination. At low PCB concentrations of up to ca 2,000 ppM, chemical methods can be used; at higher concentrations, alternative disposal options become more attractive. For chemical treatment, a small mobile unit using quick-reacting reagents has been developed for on-site decontamination. For highly contaminated transformers, retrofilling is very attractive since the owner's liability is minimized at minimum cost. Conventional flush/drain procedures have such drawbacks as the inability to remove oil trapped in windings and the leaching of trapped PCBs back into the uncontaminated retrofill oil over time. A new process has been developed to solve the leaching problem and to decontaminate the drained askarel at room temperature using a catalyst. An alternative disposal strategy involves dismantling the transformer carcass, incinerating non-recyclable materials, and cleaning the metals and wire with solvent. 8 figs

  16. Decontamination of Wastewater Contaminated by Polychlorinated Biphenyls (PCBs)

    Czech Academy of Sciences Publication Activity Database

    Kaštánek, František; Kaštánek, P.; Demnerová, K.; Maléterová, Ywetta

    2004-01-01

    Roč. 50, č. 2 (2004), s. 131-138 ISSN 0273-1223 Institutional research plan: CEZ:AV0Z4072921 Keywords : decontamination * hydrogen peroxide * underground water Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 0.586, year: 2004

  17. Radiation protection procedures for the dismantling and decontamination of nuclear facility

    International Nuclear Information System (INIS)

    Almeida, C.C.; Garcia, R.H.L.; Cambises, P.B.S.; Silva, T.M. da; Paiva, J.E.; Carneiro, J.C.G.G.; Rodrigues, D.L.

    2013-01-01

    This work presents the operational procedures and conditions to ensure the required level of protection and safety during the dismantling and decontamination of a natural uranium purification facility at IPEN-CNEN/SP, Brazil. The facility was designed for chemical processing of natural uranium, aiming to obtain the uranyl nitrate, nuclear-grade. Afterwards, the installation operated in treatment and washing of thorium sulfate and thorium oxycarbonate dissolution, to get thorium nitrate as final product. A global evaluation of the potential exposure situation was carried out by radioprotection team in order to carry out the operations planned. For the facility dismantling, was established both measures to control the radiation exposure at workplace and individual monitoring of workers. A combination of physical, chemical and mechanical methods was used in the decontamination procedure applied in this unit. Concerning the internal operation procedures of IPEN-CNEN/SP, the radioactive waste control, the transport of the radioactive materials and authorization of use of decontaminated equipment were also subject of study. (author)

  18. Decontamination of material in the Marcoule plutonium producing centre (1961)

    International Nuclear Information System (INIS)

    Rodier, J.; Bouzigues, H.; Boutot, P.

    1961-01-01

    The decontamination of material in an atomic centre is an essential operation in view of the cost and the difficulties of replacement. It also makes it possible to reduce the storage of radio-active materials always an expensive task. Surfaces are contaminated by retention of radioactive products and the mechanism of the bounding forces can be explained in terms of chemical, mechanical, electrostatic and surface tension phenomena. The methods used for decontamination are either physical (section, abrasion, steam, ultrasonics) or chemical (acids, alkalis, detergents, reducing and oxidising agents). At Marcoule, chemical methods of treatment are used. This is effected in tanks, the exact composition of the liquids being regulated from a control panel. Working experience has shown that the fact of operating in humid conditions eliminates all problems of atmospheric contamination; as a result it is possible for the personnel to work without any special protective devices. Almost all the material can be re-utilized and the operations produce only a small volume of liquid waste. The decontamination workshop is operated by a small number of workers. The working costs, including capital repayment and treatment of the waste, do not exceed 15 per cent of the value of the apparatus treated. (authors) [fr

  19. Decontamination of 2-chloroethyl ethylsulfide using titanate nanoscrolls

    Science.gov (United States)

    Kleinhammes, Alfred; Wagner, George W.; Kulkarni, Harsha; Jia, Yuanyuan; Zhang, Qi; Qin, Lu-Chang; Wu, Yue

    2005-08-01

    Titanate nanoscrolls, a recently discovered variant of TiO 2 nanocrystals, are tested as reactive sorbent for chemical warfare agent (CWA) decontamination. The large surface area of the uncapped tubules provides the desired rapid absorption of the contaminant while water molecules, intrinsic constituents of titanate nanoscrolls, provide the necessary chemistry for hydrolytic reaction. In this study the decomposition of 2-chloroethyl ethylsulfide (CEES), a simulant for the CWA mustard, was monitored using 13C NMR. The NMR spectra reveal reaction products as expected from the hydrolysis of CEES. This demonstrates that titanate nanoscrolls could potentially be employed as a decontaminant for CWAs.

  20. COMPILATION OF AVAILABLE DATA ON BUILDING DECONTAMINATION ALTERNATIVES

    Science.gov (United States)

    The report presents an analysis of selected technologies that have been tested for their potential effectiveness in decontaminating a building that has been attacked using biological or chemical warfare agents, or using toxic industrial compounds. The technologies selected to be ...

  1. Development and assessment of two decontamination processes: closed electropolishing system for decontamination of underwater surfaces -vibratory decontamination with abrasives

    International Nuclear Information System (INIS)

    Benavides, E.; Fajardo, M.

    1992-01-01

    Two decontamination processes have been developed to decontaminate the stainless steel components of nuclear power plants. The first process uses an underwater closed electropolishing system for the decontamination of large stainless steel surfaces in flooded systems without loss of electrolyte. Large underwater contaminated areas can be treated with an electropolishing head covering an area of 2 m 2 in one step. The decontamination factors achieved with this technique range between 100 and 1000. The second process consists in the decontamination of nuclear components using vibratory equipment with self-cleaning abrasives generating a minimum quantity of waste. This technique may reach contamination factors similar to those obtained with other abrasive methods (brush abrasion, abrasive blasting, etc...). The obtained decontamination factors range between 5 and 50. Only a small quantity of waste is generated, which is treated and reduced in volume by filtration and evaporation

  2. Decontamination experience using the EMMAC process in EDF nuclear power plants

    International Nuclear Information System (INIS)

    Noel, D.; Spychala, H. B.; Dupin, M.; Lantes, B.; Goulain, F.; Gregoire, J.; Jeandrot, S.

    1997-01-01

    The EMMA, EMMAC and EMMAC-PLUS decontamination processes, nondestructive tests and waste treatment are presented. The various applications of the new EMMAC soft decontamination process, used by EDF since 1995 have shown that it is a very effective tool and at the same time, is a very low corrosive process for the materials that have been treated . The improved efficiency, compared to the previous EMMA process allowed us to obtain good decontamination factors with only one cycle instead of two. At the same time, changes in chemical composition and waste treatment produced large reduction in the amount of radioactive wastes generated. Further improvements are still being sought. (authors)

  3. Assessing Ecosystem Impacts from Simulant and Decontaminant Use

    Science.gov (United States)

    1988-05-01

    reverse if necessary and identify by block number) FIELD GROUP SUB-GROUP Pollution Risk assessment Ecotoxicology 24 07 Simulants Decontaminants... ecotoxicology of those chemicals. This report presents methods from the literature and proposes a newly devised approach to rank those chemicals for damage...Oyster Reef Ecosystem Energy Flow Compartment Model 27 2. Digraph of a Nutrient-Driven Simplified Ecosystem 30 3. Digraph of a Cultivated Field Under

  4. Radiation degradation and the consequent decrease in the efficacy of some dilute chemical decontaminant formulations

    Energy Technology Data Exchange (ETDEWEB)

    Kamal Kishore; Dey, G.R.; Naik, D.B.; Moorthy, P.N. [Applied Chemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India)

    1998-12-31

    Constituents of dilute chemical decontaminant formulations such as ascorbic acid, EDTA, picolinic acid (PA) and 2,6-pyridine dicarboxylic acid (PDCA), also known as dipicolinic acid, are highly reactive with primary species produced from water radiolysis. Picolinic acid and PDCA however, are less sensitive to radiation dose due to their aromatic nature. They also help in protecting ascorbic acid when in a mixture. The efficacy for dissolution of magnetite was found to reduce drastically on irradiation in the case of EDTA/oxalic acid/citric acid while it was unaffected in the case of picolinic acid/ascorbic acid. In the case of EDTA/ascorbic acid/citric acid or PDCA/ascorbic acid formulations, there was only a marginal effect of radiation on the efficacy of the formulations. (author)

  5. Vaporous Decontamination Methods: Potential Uses and Research Priorities for Chemical and Biological Contamination Control

    Science.gov (United States)

    2006-06-01

    over time. Ammonia gas is typically used to neutralise formaldehyde forming a white precipitate, hexamethylene- tetramine, which is then washed down...sulphite scrubbers DSTO-GD-0465 4 and a carbon bed to prevent any leakage of the ClO2 gas into the environment. The decontamination period (12...of ammonia gas) produces a broad-spectrum decontaminant against C agents [7]. However, initial studies have shown that the modified vaporous

  6. Coolant system decontamination

    International Nuclear Information System (INIS)

    Anstine, L.D.; James, D.B.; Melaika, E.A.; Peterson, J.P.

    1981-01-01

    An improved method for decontaminating the coolant system of water cooled nuclear power reactors and for regenerating the decontamination solution is described. A small amount of one or more weak-acid organic complexing agents is added to the reactor coolant, and the pH is adjusted to form a decontamination solution which is circulated throughout the coolant system to dissolve metal oxides from the interior surfaces and complex the resulting metal ions and radionuclide ions. The coolant containing the complexed metal ions and radionuclide ions is passed through a strong-base anion exchange resin bed which has been presaturated with a solution containing the complexing agents in the same ratio and having the same pH as the decontamination solution. As the decontamination solution passes through the resin bed, metal-complexed anions are exchanged for the metal-ion-free anions on the bed, while metal-ion-free anions in the solution pass through the bed, thus removing the metal ions and regenerating the decontamination solution. (author)

  7. Gas phase decontamination of gaseous diffusion process equipment

    International Nuclear Information System (INIS)

    Bundy, R.D.; Munday, E.B.; Simmons, D.W.; Neiswander, D.W.

    1994-01-01

    D ampersand D of the process facilities at the gaseous diffusion plants (GDPs) will be an enormous task. The EBASCO estimate places the cost of D ampersand D of the GDP at the K-25 Site at approximately $7.5 billion. Of this sum, nearly $4 billion is associated with the construction and operation of decontamination facilities and the dismantlement and transport of contaminated process equipment to these facilities. In situ long-term low-temperature (LTLT) gas phase decontamination is being developed and demonstrated at the K-25 site as a technology that has the potential to substantially lower these costs while reducing criticality and safeguards concerns and worker exposure to hazardous and radioactive materials. The objective of gas phase decontamination is to employ a gaseous reagent to fluorinate nonvolatile uranium deposits to form volatile LJF6, which can be recovered by chemical trapping or freezing. The LTLT process permits the decontamination of the inside of gas-tight GDP process equipment at room temperature by substituting a long exposure to subatmospheric C1F for higher reaction rates at higher temperatures. This paper outlines the concept for applying LTLT gas phase decontamination, reports encouraging laboratory experiments, and presents the status of the design of a prototype mobile system. Plans for demonstrating the LTLT process on full-size gaseous diffusion equipment are also outlined briefly

  8. Comparison of thorough decontamination techniques on dismantled pieces of a PWR reactor

    International Nuclear Information System (INIS)

    Klein, M.; Rahier, A.; Mandoki, R.; Ponnet, M.

    1998-01-01

    The decontamination experience gained during the BR3 dismantling project is developed. This started with the full system decontamination of the primary loop and was followed by R and D on thorough decontamination projects. First, a wet abrasive installation has been installed and is now in operation for the thorough cleaning of metallic pieces of simple geometry. Afterwards, the chemical cerium process has been developed. The results of the regeneration with ozone and with electrochemistry are presented in detail. The ozone regeneration process has been selected for the industrial installation of which the construction is foreseen in 1998. (author)

  9. Decontamination of Savannah River Plant waste glass canisters

    International Nuclear Information System (INIS)

    Rankin, W.N.

    1982-01-01

    A Defense Waste Processing Facility (DWPF) is currently being designed to convert Savannah River Plant (SRP) liquid, high-level radioactive waste into a solid form, such as borosilicate glass. The outside of the canisters of waste glass must have very low levels of smearable radioactive contamination before they are removed from the DWPF to prevent the spread of radioactivity. Several techniques were considered for canister decontamination: high-pressure water spray, electropolishing, chemical dissolution, and abrasive blasting. An abrasive blasting technique using a glass frit slurry has been selected for use in the DWPF. No additional equipment is needed to process waste generated from decontamination. Frit used as the abrasive will be mixed with the waste and fed to the glass melter. In contrast, chemical and electrochemical techniques require more space in the DWPF, and produce large amounts of contaminated byproducts which are difficult to immobilize by vitrification

  10. Decontamination of transuranic contaminated metals by melt refining

    International Nuclear Information System (INIS)

    Heshmatpour, B.; Copeland, G.L.; Heestand, R.L.

    1983-01-01

    Melt refining of transuranic contaminated metals is a possible decontamination process with the potential advantages of producing metal for reuse and of simplifying chemical analyses. By routinely achieving the 10 nCi/g( about0.1ppm) level by melt refining, scrap metal can be removed from the transuranic waste category. (To demonstrate the effectiveness of this melt refining process, mild steel, stainless steel, nickel, and copper were contaminated with 500 ppm (μg/g) PuO 2 and melted with various fluxes. The solidified slags and metals were analyzed for their plutonium contents, and corresponding partition ratios for plutonium were calculated. Some metals were double refined in order to study the effect of secondary slag treatment. The initial weight of the slags was also varied to investigate the effect of slag weight on the degree of plutonium removal. In general, all four metals could be decontaminated below 1 ppm (μg/g) Pu ( about100 nCi/g) by a single slag treatment. Doubling the slag weight did not improve decontamination significantly; however, double slag treatment using 5 wt.% slag did decontaminate the metals to below 0.1 ppm (μg/g) Pu (10 nCi/g).)

  11. In vitro skin permeation and decontamination of the organophosphorus pesticide paraoxon under various physical conditions--evidence for a wash-in effect.

    Science.gov (United States)

    Misik, Jan; Pavlikova, Ruzena; Josse, Denis; Cabal, Jiri; Kuca, Kamil

    2012-09-01

    Misuse of various chemicals, such as chemical warfare agents, industrial chemicals or pesticides during warfare or terrorists attacks requires adequate protection. Thus, development and evaluation of novel decontamination dispositives and techniques are needed. In this study, in vitro permeation and decontamination of a potentially hazardous compound paraoxon, an active metabolite of organophosphorus pesticide parathion, was investigated. Skin permeation and decontamination experiments were carried out in modified Franz diffusion cells. Pig skin was used as a human skin model. Commercially produced detergent-based washing solutions FloraFree(™) and ArgosTM were used as decontamination means. The experiments were done under "warm", "cold", "dry" and "wet" skin conditions in order to determine an effect of various physical conditions on skin permeation of paraoxon and on a subsequent decontamination process. There was no significant difference in skin permeation of paraoxon under warm, cold and dry conditions, whereas wet conditions provided significantly higher permeation rates. In the selected conditions, decontamination treatments performed 1 h after a skin exposure did not decrease the agent volume that permeated through the skin. An exception were wet skin conditions with non-significant decontamination efficacy 18 and 28% for the FloraFree(™) and Argos(™) treatment, respectively. In contrast, the skin permeation of paraoxon under warm, cold and dry conditions increased up to 60-290% following decontamination compared to non-decontaminated controls. This has previously been described as a skin wash-in effect.

  12. Skin contamination - prevention and decontaminating

    International Nuclear Information System (INIS)

    Henning, K.

    2001-01-01

    A detailed examination is made of the structure of human skin. Measures were drawn up to prevent skin contamination in nuclear installations as well as contaminated skin was decontaminated from the personnel. By systematically applying these measures a significant level of success was achieved in preventing contamination in nuclear installations. Cases where more far-reaching chemical methods had to be used were kept to a minimum. (R.P.)

  13. Sorbents for effective removal of radioactive antimony during chemical decontamination

    International Nuclear Information System (INIS)

    Nishad, Padala Abdul; Bhaskarapillai, Anupkumar; Velmurugan, Sankaralingam

    2014-01-01

    Removal of radioactive antimony is a challenging problem. Often, during decontamination, they get mobilized around the system and redeposit in different areas thus offsetting the reduction in the radiation field obtained by removing other activities such as 60 Co. Thus, there is a clear need for better antimony removing materials/strategies for effective reactor decontamination. In this regard, six commercially available sorbents namely, Tulsion A33 (strong base anion (-OH) resin), Amberlite IRC-718 (chelating resin), Radex ® Sb-1000, nano TiO 2 -special grade (Inorganic type IX), Chitosan (biosorbent) and Aeroxide p25 (nano TiO 2 , Inorganic type IX) were evaluated for their antimony sorption properties. Radex ® and TiO 2 based materials were found to be more effective in removing both Sb(V) and Sb(III). Solution pH was seen to significantly influence the antimony sorption and the effect was more prominent in anion resin, when tested under column conditions. Apart from the commercial sorbents, we have synthesised a robust high performing sorbent (TA-Chitosan beads) in the form of stable beads, using nano-TiO 2 and chitosan. The beads were found to retain the antimony sorption properties of the nano-TiO 2 , while adapting a physical format suitable for large scale operations. The sorbent exhibited almost complete sorption of antimony both in low (ppb level) as well as high concentrations of antimony. The suitability of the beads for use in column mode has been established and its radiation stability was probed in detail. The beads were found to be stable to irradiations as ascertained from the TOC values and unchanged sorption properties. The sorption properties of the CHITA beads in typical decontamination formulation containing mixture of complexing agents have been investigated in detail. (author)

  14. Pilot scale study of a chemical treatment process for decontamination of aqueous radioactive waste of pakistan research reactor-1

    International Nuclear Information System (INIS)

    Jan, F.; Hussain, M.; Ahmad, S.S.; Aslam, M.; Haq, E.U.

    2007-12-01

    Chemical treatment process for the low level liquid radioactive waste generated at PINSTECH was previously optimized on lab-scale making use of coprecipitation of hydrous oxides of iron in basic medium. Ferrous sulfate was used as coagulant. Batch wise application of this procedure on pilot scale has been tested on a 1200 L batch volume of typical PINSTECH liquid waste. Different parameters and unit operations have been evaluated. The required data for the construction of a small size treatment plant envisioned can be used for demonstration/teaching purpose as well as for the decontamination of the waste effluents of the Institute. The lab-scale process parameters were verified valid on pilot scale. It was observed that reagent doses can further be economized with out any deterioration of the Decontamination Factors (DF) achieved or of any other aspect of the process. This simple, cost- effective, DF-efficient and time-smart batch wise process could be coupled with an assortment of other treatment operations thus affording universal application. Observations recorded during this study are presented. (author)

  15. A decontamination technique for decommissioning waste

    International Nuclear Information System (INIS)

    Heki, H.; Hosaka, K.; Kuribayashi, N.; Ishikura, T.

    1993-01-01

    A large amount of radioactive metallic waste is generated from decommissioned commercial nuclear reactors. It is necessary from the point of environmental protection and resource utilization to decontaminate the contaminated metallic waste. A decommissioning waste processing system has been previously proposed considering such decommissioning waste characteristics as its large quantity, large radioactivity range, and various shapes and materials. The decontamination process in this system was carried out by abrasive blasting as pretreatment, electrochemical decontamination as the main process, and ultrasonic cleaning in water as post-treatment. For electrochemical decontamination, electrolytic decontamination for simple shaped waste and REDOX decontamination for complicated shaped waste were used as effective decontamination processing. This time, various kinds of actual radioactive contaminated samples were taken from operating power plants to simulate the decontamination of decommissioning waste. After analyzing the composition, morphogenesis and surface observation, electrolytic decontamination, REDOX decontamination, and ultrasonic cleaning experiments were carried out by using these samples. As a result, all the samples were decontaminated below the assumed exemption level(=4 x 10 -2 Bq/g). A maximum decontamination factor of over 104 was obtained by both electrolytic and REDOX decontamination. The stainless steel sample was easy to decontaminate in both electrochemical decontaminations because of its thin oxidized layer. The ultrasonic cleaning process after electrochemical decontamination worked effectively for removing adhesive sludge and the contaminated liquid. It has been concluded from the results mentioned above that electrolytic decontamination and REDOX decontamination are effective decontamination process for decontaminating decommissioning waste

  16. Functional and operational design requirements for decontamination and decommissioning of the EBR-I Mark-II NaK: Final report

    International Nuclear Information System (INIS)

    Brown, B.W.; Crandall, D.L.; Dafoe, R.E.; Dolenc, M.R.; LaRue, D.M.

    1987-09-01

    Approximately 180 gal of sodium/potassium (NaK) eutectic liquid metal were severely radioactively contaminated during a meltdown of the Mark-II core of the Experimental Breeder Reactor-I (EBR-I) in November 1955. This contaminated NaK, which is contained in four vessels, is currently stored in an underground bunker located at the Army Reentry Vehicle Facility Site (ARVFS) located approximately at the center of the Idaho National Engineering Laboratory (INEL). This document presents the Functional and Operational Requirements (F and ORs) for the D and D of the contaminated NaK and the ARVFS bunker site. This project will chemically deactivate the NaK; dispose of the radioactively contaminated product at a designated burial site; chemically deactivate any residual NaK in the containers, and dispose of the containers at a designated burial site; decontaminate and decommission any contaminated process equipment used in these operations, and decontaminate and decommission the ARVFS bunker site. Completion of the above technical objectives will allow for the effective disposition of the NaK, and will return the ARFVS bunker and immediate area to a reusable condition. Upon completion, the ARVFS NaK, which is now considered a significant potential hazard, will be removed from the Surplus Facilities Management Program priority listing of projects. 33 refs., 8 figs

  17. Use of irradiation for chemical and microbial decontamination of water, wastewater and sludge. Final report of a co-ordinated research project 1995-1999

    International Nuclear Information System (INIS)

    2001-06-01

    The co-ordinated research project (CRP) was established in order to focus the attention of appropriate technical experts in integrating the effects of ionizing radiation on refractory organic pollutants and pathogenic microorganisms and parasites in the treatment of water, waste water and sewage sludge. This publication describes the findings of the CRP in three subject areas: ground water remediation, decontamination of industrial and municipal waste water and sewage sludge hygienization. This publication contains 11 individual papers from participants; each of the papers was indexed separately

  18. Physicochemical characteristics of PFC surfactants for dry decontamination

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Won Jin; Lee, Chi Woo [Korea University, Seoul (Korea)

    2001-04-01

    Even the trace amount of the used nuclear fuels of high radioactivity are hazardous to the earth and humans. Perfluorocarbons and perfluorocarbon surfactants are emerging to be efficient chemicals in the dry decontamination process of the used fuels of high radioactivity. The theme was undertaken to increase the knowledge on perfluorocarbon surfactants to develop the perfluorocarbon system in the dry decontamination process in Korea. Several cationic and anionic pfc surfactants were synthesized. Effects of pfc surfactants on electrochemical etching of silicon were investigated to form porous silicons. Forces were measured between silicon surfaces and AFM tip in the absence and presence of pfc surfactants. 7 refs., 10 figs. (Author)

  19. Decontaminating agents and decontamination processes for nuclear industry and for plant demolition

    International Nuclear Information System (INIS)

    Henning, Klaus; Gojowczyk, Peter

    2012-01-01

    Decontamination of surfaces of materials in nuclear facilities or in nuclear power plants under demolition can be carried out successfully if surface treatment is performed by dipping or in an ultrasonic bath by alternating between alkaline and acid baths with intermediate rinsing in demineralized water. Decontaminating aluminium surfaces sensitive to corrosion requires further treatment in an ultrasonic bath, after the first 2 ultrasonic baths, with a weak alkaline decontaminating agent. This applies alike to components to be decontaminated for re-use and parts of materials to be disposed of. The decontamination action depends on the surfaces either being free from corrosion or else showing pronounced corrosion. (orig.)

  20. Skin decontamination of G, V, H L agents by Canadian reactive skin decontaminant lotion

    Energy Technology Data Exchange (ETDEWEB)

    Bide, R.W.; Sawyer, T.W.; DiNinno, V.L.; Armour, S.J.; Risk, D.J.

    1993-05-13

    The Canadian Reactive Skin Decontaminant Lotion (RSDL) is a reactive solution designed to be applied directly to skin for the decontamination and destruction of the classical chemical warfare agents. The solvent of the RSDL is very effective in dissolving liquid agents from the skin surface and the differential solubility of agents in the RSDL and the skin strongly favors retention of agents in the lotion. The active ingredient in the RSDL reacts rapidly and completely with G-agents, V-agents, mustard Lewisite producing relatively nontoxic products. The RSDL will dissolve and destroy agent thickened with acrylate polymers. The lotion is water soluble and readily removed from the skin. Since the RSDL is water soluble, it is active against water soluble agents even at high dilutions. For water insoluble agents, the activity is reduced as the water content rises above abrasive 50% due to insolubility of the agents. Skin and eye irritancy trials indicate that the RSDL is only a mild irritant to the eyes (equivalent to a chlorinated swimming pool) and to abraded skin. Acute toxicity trials showed that large oral and intraperitoneal doses were essentially non-toxic. The RSDL was fielded by the Canadian Forces for the Gulf Conflict. The RSDL may be used in open wounds for short periods. Wound decontamination and irrigation with RSDL diluted 1:1 with isotonic saline was recommended for the Gulf conflict.

  1. Actual situation on the field of decontamination in Slovak and Czech NPPs

    International Nuclear Information System (INIS)

    Prazska, M.; Rezbarik, J.; Solcanyi, M.; Trtilek, R.

    2002-01-01

    Many decontamination methods for various applications have proved to provide good results at Slovak and Czech nuclear power plants. A number of mechanical, chemical and electrochemical decontamination methods are available. The selection of a suitable method and decontamination technology is the result of a multicriterial optimization. The plants use the decontamination procedures described in the design documentation. New decontamination procedures aiming to minimize secondary radioactive wastes and corrosion attack on the basic material are being developed. No standardized qualification process, however, exists for such new procedures and large efforts are to be made to introduce them into practice. Methods for decommissioning purposes are based on static or dynamic application of decontamination solutions such as a mixture of formic acid + complexing agent + corrosion inhibitor or dilute HNO 3 . A process consisting in treatment in a solution containing formic acid + complexing agent + corrosion inhibitor (total concentration 3 - 4 mass %, temperature 30 - 35 deg C), whose effect is enhanced by the application of ultrasound (0.4 - 0.5 W per cm 2 decontaminated area) in a specially designed bath, is recommended for segmented metallic parts, which can be then released into the environment and recycled. Electrochemical decontamination in a bath is another efficient decontamination method to achieve unrestricted release of the material into the environment. Efficient decontamination of various highly contaminated materials can be attained by using an electrolyte solution based on citric acid (100 g.dm -3 ) + nitric acid (20 g.dm -3 ) + NH 4 NO 3 (50 g.dm -3 ) and applying a current density of 100 - 200 mA.cm -2 , electrolyte temperature 25 - 50 deg C, with one decontamination cycle period not exceeding 30 minutes. The best results are obtained by electrolysis followed by mechanical treatment using ultrasound. Electrochemical decontamination using a spraying

  2. Decontamination impacts on solidification and waste disposal

    International Nuclear Information System (INIS)

    Kempf, C.R.; Soo, P.

    1988-01-01

    Research to determine chemical and physical conditions which could lead to thermal excursions, gas generation, and/or general degradation of decontamination-reagent-loaded resins has shown that IRN-78, IONAC A-365, and IRN-77 organic ion exchange resin moisture contents vary significantly depending on the counter ion ''loading.'' The extent/vigor of the reaction is very highly dependent on the degree of dewatering of the resins and on the method of solution addition. The heat generation may be due, in part, to the heat of neutralization. In studies of the long-term compatibility effects of decontamination waste resins in contact with waste package container materials in the presence of decontamination reagents, radiolysis products and gamma irradiation, it has been found that the corrosion of carbon steel and austenitic stainless steel in mixed bed resins is enhanced by gamma irradiation. However, cracking in high density polyethylene is essentially eliminated because of the rapid removal of oxygen from the environment by gamma-induced oxidation of the large resin mass. 13 refs., 10 figs., 3 tabs

  3. Reduced weight decontamination formulation utilizing a solid peracid compound for neutralization of chemical and biological warfare agents

    Science.gov (United States)

    Tucker, Mark D [Albuquerque, NM

    2011-09-20

    A reduced weight decontamination formulation that utilizes a solid peracid compound (sodium borate peracetate) and a cationic surfactant (dodecyltrimethylammonium chloride) that can be packaged with all water removed. This reduces the packaged weight of the decontamination formulation by .about.80% (as compared to the "all-liquid" DF-200 formulation) and significantly lowers the logistics burden on the warfighter. Water (freshwater or saltwater) is added to the new decontamination formulation at the time of use from a local source.

  4. Decontamination Systems Information and Research Program. Quarterly technical progress report, January 1--March 31, 1993

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This reports reports the progress/efforts performed on six technical projects: 1. systematic assessment of the state of hazardous waste clean-up technologies; 2. site remediation technologies (SRT):drain- enhanced soil flushing for organic contaminants removal; 3. SRT: in situ bio-remediation of organic contaminants; 4. excavation systems for hazardous waste sites: dust control methods for in-situ nuclear waste handling; 5. chemical destruction of polychlorinated biphenyls; and 6. development of organic sensors: monolayer and multilayer self-assembled films for chemical sensors.

  5. Development of new chemical and electrochemical decontamination methods for selected equipment of WWER-440 and WWER-1000 reactor primary circuit

    International Nuclear Information System (INIS)

    Solcanyi, M.; Majersky, D.

    1998-01-01

    Special devices for in-situ application of decontamination technologies assigned for Steam Generator, Pressurizer and Main Circulating Casing of WWER-1000 type were designed, manufactured and tested in real conditions of their use in above Primary Circuit components. New decontamination technologies like low-concentration process NP-NHN for the decontamination of the Steam Generator, combined chemico-mechanical treatment for the Pressurizer and semi-dry electrolysis for the Main Circulating Pump Casing were developed and approved for their safe plant application from point of view of decontamination efficiency, corrosion influence and processing of secondary wastes. Main technological parameters were defined to achieve high decontamination efficiency and corrosion-safe application of all decontamination technologies. (author)

  6. Studies of radioactive deposition on farm buildings and testing of some methods for decontamination

    International Nuclear Information System (INIS)

    Andersson, Inger; Erlandsson, B.; Hansson, J.; Dolby, C.M.

    1993-01-01

    Studies were made of radioactive fallout on roofs of farm buildings and of some methods of decontamination. The aim was to find ways of reducing the external radiation dose to farmers working and farm animals housed in stables in a fallout situation. The roof material studied was steel plate (A) and tile (B,C, D), each with four sample areas of ca. 1 m 2 . The roof samples were collected at three places and from totally four building in regions which in 1986 (after the Chernobyl fallout) has a 137 Cs ground depositions of 3040 kBq/m 2 (A, B, C) and > 100 kBq/m 2 (D). Four different decontamination methods were tested: 1. High pressure washing with water. 2. Repeated high pressure washing with water. 3. Application of foam of a sanitizing chemical for livestock buildings followed by high pressure washing with water. 4. Application of a solution of KCl followed by high pressure washing with water. In C, the effect of decontamination expressed as the percentage decrease of the 137 Cs activity was on average for all methods, 55%. This material was coated before the decontamination by a marked growth of algae or moss, which was effectively washed off during the sanitizing procedure. In B, the average activity decontamination effect was 25%, while in D (with the highest original activity, but without growth of organic material) the effect was very small, 3%. In A, the activity level before decontamination was so low that measurements after decontamination were considered unnecessary. Method number 4 was the most effective in B and C, 32% and 64%, respectively, while method number 3 was the most effective in D, 5.7%. The results indicate that good effects can be achieved in radioactivity decontamination of roof material with equipment and chemicals which are normally available on farms

  7. Comparison of four different fuller's earth formulations in skin decontamination.

    Science.gov (United States)

    Roul, Annick; Le, Cong-Anh-Khanh; Gustin, Marie-Paule; Clavaud, Emmanuel; Verrier, Bernard; Pirot, Fabrice; Falson, Françoise

    2017-12-01

    Industrial accidents, wars and terrorist threats are potential sources of skin contamination by highly toxic chemical warfare agents and manufacturing compounds. We have compared the time-dependent adsorption capacity and decontamination efficiency of fuller's earth (FE) for four different formulations for the molecular tracer, 4-cyanophenol (4-CP), in vitro and ex vivo using water decontamination as standard. The adsorption capacity of FE was assessed in vitro for 4-CP aqueous solutions whereas decontamination efficiency was investigated ex vivo by tracking porcine skin 4-CP content using attenuated total reflectance Fourier transform infrared spectroscopy. Decontamination was performed on short time, exposed porcine skin to 4-CP by application of FE: (1) as free powder; (2) loaded on adhesive tape; (3) on powdered glove; or (4) in suspension. Removal rate of 4-CP from aqueous solutions correlates with the amount of FE and its contact time. Decontamination efficiency estimated by the percentage of 4-CP recovery from contaminated porcine skin, achieved 54% with water, ranged between ~60 and 70% with dry FE and reached ~90% with FE suspension. Successful decontamination of the FE suspension, enabling a dramatic reduction of skin contamination after a brief exposure scenario, appears to be rapid, reliable and should be formulated in a new device ready to use for self-application. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Dissolution of magnetite in a dilute chemical decontaminant formulation containing gallic acid as a reductant

    International Nuclear Information System (INIS)

    Kishore, Kamal; Rajesh, Puspalata; Dey, G.R.

    2000-01-01

    Gallic acid (GA) was tried as a reductant in place of ascorbic acid in dilute chemical decontaminant (DCD) formulations. Dissolution of magnetite in GA based DCD formulations was studied at 50 deg as well as 80 degC. It was found to be a good substitute for ascorbic acid in EDTA/ascorbic acid/citric acid i.e. EAC formulation. The efficiency of EDTA/GA/CA formulation was as good as that of EAC formulation. 2.8 was found to be the optimum pH for this formulation and dissolution decreased at lower as well as higher pHs. The ion-exchange behaviour of GA is also appropriate for using it in a regenerating type of formulation. Being an aromatic compound, gallic acid has inherent stability against radiation degradation. (author)

  9. Decontamination of body surface

    International Nuclear Information System (INIS)

    Harase, Chieko.

    1989-01-01

    There are two important points for an effective application of decontamination procedures. One is the organizing method of responsible decontamination teams. The team should be directed by medical doctor with the knowledge of decontamination of radionuclides. The other point is the place of application of the decontamination. Hospitals and clinics, especially with a department of nuclear medicine, or specialized units such as an emergency medical center are preferable. Before decontamination procedures are initiated, adequate monitoring of the body surface should be undertaken by a competent person in order to demarcate the areas which are contaminated. There are fundamental principles which are applicable to all decontamination procedures. (1) Precautions must always be taken to prevent further spread of contamination during decontamination operations. (2) Mild decontamination methods should be tried before resorting to treatment which can damage the body surface. The specific feature of each contamination varies widely in radionuclides involved, place and area of the contamination, condition of the contaminated skin such as whether the skin is wounded or not, and others. Soap and water are usually good detergents in most cases. If they fail, orange oil cream (SUPERDECONCREAM, available from Tokyo Engineering Co.) specially prepared for decontamination of radionuclides of most fission and corrosion products may be used. Contaminated hair should be washed several times with an efficient shampoo. (author)

  10. Dry decontamination for tritiated wastes

    International Nuclear Information System (INIS)

    Shi Zhengkun; Wu Tao; Dan Guiping; Xie Yun

    2009-01-01

    To aim at decontamination of tritiated wastes, we have developed and fabricated a dry tritium decontamination system, which is designed to reduce tritium surface contamination of various alloy by UV, ozone and heating. The result indicates that the elevation of temperature can obviously improve decontamination effect. With 3 h irradiation by 365 nm UV at 220 degree C, it has a decontamination rate of 99% to stainless steel surface. Ozone can more obviously improve decontamination effect when metal was heated. Ozone has a decontamination effect beyond 95% to stainless steel, aluminum and brass at 220 degree C. Tritium surface concentration of metal has a little increase after decontamination. (authors)

  11. Ontario Hydro decontamination experience

    Energy Technology Data Exchange (ETDEWEB)

    Lacy, C S; Patterson, R W; Upton, M S [Chemistry and Metallurgy Department, Central Production Services, Ontario Hydro, ON (Canada)

    1991-04-01

    Ontario Hydro currently operates 18 nuclear electric generating units of the CANDU design with a net capacity of 12,402 MW(e). An additional 1,762 MW(e) is under construction. The operation of these facilities has underlined the need to have decontamination capability both to reduce radiation fields, as well as to control and reduce contamination during component maintenance. This paper presents Ontario Hydro decontamination experience in two key areas - full heat transport decontamination to reduce system radiation fields, and component decontamination to reduce loose contamination particularly as practised in maintenance and decontamination centres. (author)

  12. Ontario Hydro decontamination experience

    International Nuclear Information System (INIS)

    Lacy, C.S.; Patterson, R.W.; Upton, M.S.

    1991-01-01

    Ontario Hydro currently operates 18 nuclear electric generating units of the CANDU design with a net capacity of 12,402 MW(e). An additional 1,762 MW(e) is under construction. The operation of these facilities has underlined the need to have decontamination capability both to reduce radiation fields, as well as to control and reduce contamination during component maintenance. This paper presents Ontario Hydro decontamination experience in two key areas - full heat transport decontamination to reduce system radiation fields, and component decontamination to reduce loose contamination particularly as practised in maintenance and decontamination centres. (author)

  13. Decontamination and decommissioning the Tokamak Fusion Test Reactor

    International Nuclear Information System (INIS)

    Walton, G.R.; Perry, E.D.; Commander, J.C.; Spampinato, P.T.

    1994-01-01

    The Tokamak Fusion Test Reactor (TFTR) is scheduled to complete its end-of-life deuterium-tritium (D-T) experiments in September 1994. The D-T operation will result in the TFTR machine structure becoming activated, and plasma facing and vacuum components will be contaminated with tritium. The resulting machine activation levels after a two year cooldown period will allow hands on dismantling for external structures, but require remote dismantling for the vacuum vessel. The primary objective of the Decontamination and Decommissioning (D ampersand D) Project is to provide a facility for construction of a new Department of Energy (DOE) experimental fusion reactor by March 1998. The project schedule calls for a two year shutdown period when tritium decontamination of the vacuum vessel, neutral beam injectors and other components will occur. Shutdown will be followed by an 18 month period of D ampersand D operations. The technical objectives of the project are to: safely dismantle and remove components from the test cell complex; package disassembled components in accordance with applicable regulations; ship packages to a DOE approved disposal or material recycling site; and develop expertise using remote disassembly techniques on a large scale fusion facility. This paper discusses the D ampersand D objectives, the facility to be decommissioned, and the technical plan that will be implemented

  14. Research and development activities of the Institut fuer Nukleare Entsorgungstechnik on the decontamination of surfaces

    International Nuclear Information System (INIS)

    Dippel, T.; Hentschel, D.; Kunze, S.

    1983-06-01

    After developing a procedure for the ''Testing of Surface Coating Materials for the Decontamination'' about 900 different surface coating materials had been tested and evaluated for the domestic and foreign industry. The results prove the following basic facts: Surface coatings, low in porosity, forming a smooth surface and containing limited amounts of filler are in the majority very effectively decontaminated if they are prepared of chemically stable, water repellent materials; Decontamination results are drastically poorer if the degree of filling of the materials is high especially if hygroscopic fillers and/or hygroscopic colouring matters are used. Currently available cleansers and washing powders used for decontamination did not fulfill the three basic demands for a decontamination agent: high efficiency, small foam generation and sufficient thermal stability. Therefore for the decontamination of walls, floors, etc. a water delutable, liquid cleanser was developed. In the same context a washing powder was optimized for the decontamination of contaminated clothing. The experiments on the decontamination of stainless steels ended up with the formulation of a pickling paste. Furthermore all investigations were aimed at a minimization of the waste generation by the decontamination process. This resulted in decontamination techniques, in which the decontaminating agents were applied in thin layers. A comparison of the currently practiced dipping technique with the coating technique showed that the latter one gave the better decontamination results and that the amount of decontamination waste was reduced. (orig./HP) [de

  15. Electrodialytic decontamination of spent ion exchange resins

    International Nuclear Information System (INIS)

    Nott, B.R.

    1982-01-01

    Development of a novel electrodialytic decontamination process for the selective removal of radioactive Cs from spent ion exchange resins containing large amounts of Li is described. The process involves passage of a dc electric current through a bed of the spent ion exchange resin in a specially designed electrodialytic cell. The radiocesium so removed from a volume of the spent resin is concentrated onto a much smaller volume of a Cs selective sorbent to achieve a significant radioactive waste volume reduction. Technical feasibility of the electrodialytic resin decontamination process has been demonstrated on a bench scale with a batch of simulated spent ion exchange resin and using potassium cobalt ferrocyanide as the Cs selective sorbent. A volume reduction factor between 10 and 17 has been estimated. The process appears to be economically attractive. Improvements in process economics can be expected from optimization of the process. Other possible applications of the EDRD process have been identified

  16. Effects of soil stripping and dressing for decontamination of radioactive materials on soil fertility of agricultural land

    International Nuclear Information System (INIS)

    Yoshino, Namiko; Takahashi, Yoshihiko; Kobayashi, Hiroyuki; Saitou, Kunihito

    2015-01-01

    Farms that were highly contaminated with radioactive materials following the Tokyo Electric Power Company (TEPCO) Fukushima Daiichi nuclear power plant accident were decontaminated by removing topsoil and subsequently dressing with fresh soil. We investigated the chemical properties of soils following such decontamination on farms in Iitate village, Fukushima. The nitrogen content of dressed soil was considerably lower than that of the subsoil that was not stripped for decontamination, as a result of which the amount of dressed soil greatly affected the soil fertility of decontaminated farms. The potassium (K) content of soil differs markedly depending on the type of soil dressing material used; accordingly, the type of soil dressing material affected the soil K content on decontaminated farms. On most of the decontaminated farms where sandy soils were used as the soil dressing material, soil exchangeable K contents were less than 25 mg K_2O/100 g, which is the criterion value for inhibiting cesium absorption in rice and soybean cultivation. However, even in the soil dressing material from agricultural land, soil K content after soil dressing was generally lower than that before soil dressing. During fallow management and at the restart of cultivation on decontaminated farms, it is important to know in advance the chemical properties of soil and take the necessary measures based on this information. (author)

  17. Treatment of low and intermediate aqueous waste containing Cs-137 by chemical precipitation

    International Nuclear Information System (INIS)

    Valdezco, E.M.; Marcelo, E.A.; Alamares, A.L.; Junio, J.B.; Dela Cruz, J.M.

    1996-01-01

    The use of radioactive materials in various applications has been increasing since its introduction in the early sixties. The Philippine Nuclear Research Institute has established a centralized facility for treating radioactive wastes i.e. aqueous wastes with assistance from the International Atomic Energy Agency - Technical Cooperation Programme. Liquid wastes containing Cs-137 are generated from aqueous wastes containing Cs-137 by nickel ferrocyanide precipitation will be presented. The aim of this study is to investigate the efficiency treatment in removing Cs-137 from an aqueous effluent. Actual aqueous wastes known to contain Cs-137 were used in the experiments. Low cost and simple nickel ferrocyanide precipitation method with the aid of a flocculant has been selected for the separation of Cs-137 from low and intermediate aqueous waste. By varying the chemical dosage added into the aqueous waste, different decontamination factors were obtained. Hence, the optimum dosage of the chemicals that give the highest decontamination factor can be determined. (author)

  18. Decontamination sheet

    International Nuclear Information System (INIS)

    Hirose, Emiko; Kanesaki, Ken.

    1995-01-01

    The decontamination sheet of the present invention is formed by applying an adhesive on one surface of a polymer sheet and releasably appending a plurality of curing sheets. In addition, perforated lines are formed on the sheet, and a decontaminating agent is incorporated in the adhesive. This can reduce the number of curing operation steps when a plurality steps of operations for radiation decontamination equipments are performed, and further, the amount of wastes of the cured sheets, and operator's exposure are reduced, as well as an efficiency of the curing operation can be improved, and propagation of contamination can be prevented. (T.M.)

  19. Fighting Ebola through Novel Spore Decontamination Technologies for the Military

    Directory of Open Access Journals (Sweden)

    Christopher J. Doona

    2015-08-01

    Full Text Available AbstractRecently, global public health organizations such as Doctors without Borders (MSF, the World Health Organization (WHO, Public Health Canada, National Institutes of Health (NIH, and the U.S. government developed and deployed Field Decontamination Kits (FDKs, a novel, lightweight, compact, reusable decontamination technology to sterilize Ebola-contaminated medical devices at remote clinical sites lacking infra-structure in crisis-stricken regions of West Africa (medical waste materials are placed in bags and burned. The basis for effectuating sterilization with FDKs is chlorine dioxide (ClO2 produced from a patented invention developed by researchers at the US Army – Natick Soldier RD&E Center (NSRDEC and commercialized as a dry mixed-chemical for bacterial spore decontamination. In fact, the NSRDEC research scientists developed an ensemble of ClO2 technologies designed for different applications in decontaminating fresh produce; food contact and handling surfaces; personal protective equipment; textiles used in clothing, uniforms, tents, and shelters; graywater recycling; airplanes; surgical instruments; and hard surfaces in latrines, laundries, and deployable medical facilities. These examples demonstrate the far-reaching impact, adaptability, and versatility of these innovative technologies. We present herein the unique attributes of NSRDEC’s novel decontamination technologies and a Case Study of the development of FDKs that were deployed in West Africa by international public health organizations to sterilize Ebola-contaminated medical equipment. FDKs use bacterial spores as indicators of sterility. We review the properties and structures of spores and the mechanisms of bacterial spore inactivation by ClO2. We also review mechanisms of bacterial spore inactivation by novel, emerging, and established nonthermal technologies for food preservation, such as high pressure processing, irradiation, cold plasma, and chemical sanitizers

  20. Psychosocial considerations for mass decontamination

    International Nuclear Information System (INIS)

    Lemyre, L.; Johnson, C.; Corneil, W.

    2010-01-01

    Mass exposure to explosions, infectious agents, food-borne illnesses, chemicals or radiological materials may require mass decontamination that have critical psychosocial implications for the public and for both traditional and non-traditional responders in terms of impact and of response. Five main issues are common to mass decontamination events: (i) perception, (ii) somatisation, (iii) media role and communication, (iv) information sharing, (v) behavioural guidance and (vi) organisational issues. Empirical evidence is drawn from a number of cases, including Chernobyl; Goiania, Brazil; the sarin gas attack in Tokyo; the anthrax attacks in the USA; Three Mile Island; and by features of the 2003 severe acute respiratory syndrome pandemic. In this paper, a common platform for mass casualty management is explored and suggestions for mass interventions are proposed across the complete event timeline, from pre-event threat and warning stages through to the impact and reconstruction phases. Implication for responders, health care and emergency infrastructure, public behaviour, screening processes, risk communication and media management are described. (authors)

  1. Evaluation of laryngoscopes decontamination practices in different hospitals

    International Nuclear Information System (INIS)

    Ahmad, M.; Hussain, W.; Saleem, A.; Saqib, M

    2014-01-01

    To find disinfection and sterilization practices of laryngoscope in different hospitals. Study Design: Descriptive study. Materials and Methods: Laryngoscope decontamination practices in different hospitals were evaluated in this study which was based on a telephonic structured questionnaire. Preset questions were asked on phone from operation room technicians of 50 different hospitals. For clarification and confirmation of procedure anesthesiologist of the hospital was contracted. Laryngoscope decontamination practices were asked as per questionnaire and data collected was recorded and analyzed. Results were documented and compared with studies regarding laryngoscope decontamination practices of different countries. Results: Most exercised methods were manual decontamination with simple gauze (50%), alcohol gauze (11%) or tap water (27%). The use of disposable blades and sheathing of blades was not practiced by any of the hospitals. Similarly chemical disinfectants were used rarely (2%). Rinsing laryngoscopes with water (always 27%, sometimes 23%) was very common while, autoclaving or sheathing of blades was not done in any of the hospital. Conclusion: The rate of different postoperative infection is on the increase in our hospitals and one likely contributing source is contaminated laryngoscopes. Lack of awareness and poor practices among health care professionals, over work and economic constraints are the major contributing factors which need to be controlled by adhering to international standards. (author)

  2. Pickering emulsions for skin decontamination.

    Science.gov (United States)

    Salerno, Alicia; Bolzinger, Marie-Alexandrine; Rolland, Pauline; Chevalier, Yves; Josse, Denis; Briançon, Stéphanie

    2016-08-01

    This study aimed at developing innovative systems for skin decontamination. Pickering emulsions, i.e. solid-stabilized emulsions, containing silica (S-PE) or Fuller's earth (FE-PE) were formulated. Their efficiency for skin decontamination was evaluated, in vitro, 45min after an exposure to VX, one of the most highly toxic chemical warfare agents. Pickering emulsions were compared to FE (FE-W) and silica (S-W) aqueous suspensions. PE containing an oil with a similar hydrophobicity to VX should promote its extraction. All the formulations reduced significantly the amount of VX quantified on and into the skin compared to the control. Wiping the skin surface with a pad already allowed removing more than half of VX. FE-W was the less efficient (85% of VX removed). The other formulations (FE-PE, S-PE and S-W) resulted in more than 90% of the quantity of VX removed. The charge of particles was the most influential factor. The low pH of formulations containing silica favored electrostatic interactions of VX with particles explaining the better elimination from the skin surface. Formulations containing FE had basic pH, and weak interactions with VX did not improve the skin decontamination. However, these low interactions between VX and FE promote the transfer of VX into the oil droplets in the FE-PE. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Cutaneous challenge with chemical warfare agents in the SKH-1 hairless mouse. (I) Development of a model for screening studies in skin decontamination and protection.

    Science.gov (United States)

    Dorandeu, F; Taysse, L; Boudry, I; Foquin, A; Hérodin, F; Mathieu, J; Daulon, S; Cruz, C; Lallement, G

    2011-06-01

    Exposure to lethal chemical warfare agents (CWAs) is no longer only a military issue due to the terrorist threat. Among the CWAs of concern are the organophosphorus nerve agent O-ethyl-S-(2[di-isopropylamino]ethyl)methyl-phosphonothioate (VX) and the vesicant sulfur mustard (SM). Although efficient means of decontamination are available, most of them lose their efficacy when decontamination is delayed after exposure of the bare skin. Alternatively, CWA skin penetration can be prevented by topical skin protectants. Active research in skin protection and decontamination is thus paramount. In vivo screening of decontaminants or skin protectants is usually time consuming and may be expensive depending on the animal species used. We were thus looking for a suitable, scientifically sound and cost-effective model, which is easy to handle. The euthymic hairless mouse Crl: SKH-1 (hr/hr) BR is widely used in some skin studies and has previously been described to be suitable for some experiments involving SM or SM analogs. To evaluate the response of this species, we studied the consequences of exposing male anaesthetized SKH-1 mice to either liquid VX or to SM, the latter being used in liquid form or as saturated vapours. Long-term effects of SM burn were also evaluated. The model was then used in the companion paper (Taysse et al.(1)).

  4. Decontamination method

    International Nuclear Information System (INIS)

    Tsujimura, Hiroshi; Ono, Shigeki; Tada, Nobuo; Tamai, Yasumasa; Okada, Masaya; Kurihara, Masayuki; Onuki, Toyomitsu; Toyota, Seiichi

    1998-01-01

    Before contamination of materials to be decontaminated, a surface of a region where a strippable paint is to be coated is smoothed by an epoxy resin previously. Then, a waterproof sheet is extended to the material to be decontaminated, and the strippable paint is applied to the periphery or the entire surface of the sheet. In order to facilitate peeling, the strippable paint is not applied to a portion of the outer circumference of the sheet. Even if the contaminating circumstance is an air atmosphere or a liquid such as reactor water, since the sheet itself has waterproofness and the strippable paint excellent in gas and water tightness is applied to the periphery, contamination is eliminated. When decontaminating the material to be decontaminated having contaminated surfaces, if the sheet for the start of peeling is picked up and the sheet is peeled, the strippable paint at the periphery thereof can be peeled off together with the sheet. (N.H.)

  5. Decontamination method

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Hiroshi; Ono, Shigeki; Tada, Nobuo; Tamai, Yasumasa; Okada, Masaya; Kurihara, Masayuki [Hitachi Ltd., Tokyo (Japan); Onuki, Toyomitsu; Toyota, Seiichi

    1998-10-27

    Before contamination of materials to be decontaminated, a surface of a region where a strippable paint is to be coated is smoothed by an epoxy resin previously. Then, a waterproof sheet is extended to the material to be decontaminated, and the strippable paint is applied to the periphery or the entire surface of the sheet. In order to facilitate peeling, the strippable paint is not applied to a portion of the outer circumference of the sheet. Even if the contaminating circumstance is an air atmosphere or a liquid such as reactor water, since the sheet itself has waterproofness and the strippable paint excellent in gas and water tightness is applied to the periphery, contamination is eliminated. When decontaminating the material to be decontaminated having contaminated surfaces, if the sheet for the start of peeling is picked up and the sheet is peeled, the strippable paint at the periphery thereof can be peeled off together with the sheet. (N.H.)

  6. Modelling Mass Casualty Decontamination Systems Informed by Field Exercise Data

    Directory of Open Access Journals (Sweden)

    Richard Amlôt

    2012-10-01

    Full Text Available In the event of a large-scale chemical release in the UK decontamination of ambulant casualties would be undertaken by the Fire and Rescue Service (FRS. The aim of this study was to track the movement of volunteer casualties at two mass decontamination field exercises using passive Radio Frequency Identification tags and detection mats that were placed at pre-defined locations. The exercise data were then used to inform a computer model of the FRS component of the mass decontamination process. Having removed all clothing and having showered, the re-dressing (termed re-robing of casualties was found to be a bottleneck in the mass decontamination process during both exercises. Computer simulations showed that increasing the capacity of each lane of the re-robe section to accommodate 10 rather than five casualties would be optimal in general, but that a capacity of 15 might be required to accommodate vulnerable individuals. If the duration of the shower was decreased from three minutes to one minute then a per lane re-robe capacity of 20 might be necessary to maximise the throughput of casualties. In conclusion, one practical enhancement to the FRS response may be to provide at least one additional re-robe section per mass decontamination unit.

  7. Overview of decommissioning and decontamination technical information support activities funded by the US Department of Energy's remedial action programs

    International Nuclear Information System (INIS)

    Owen, P.T.

    1986-01-01

    In 1979 the US Department of Energy (DOE) established the Remedial Action Program Information Center (RAPIC) at the Oak Ridge National Laboratory to provide technical information support to the Surplus Facilities Management Program, DOE's national decommissioning and decontamination (D and D) program which is managed by DOE's Richland Operations Office and UNC Nuclear Industries, Inc., and to the other DOE remedial action programs. Specific information activities that RAPIC performs to support the DOE's programs and the D and D community include: maintaining a computerized bibliographic database containing about 4500 annotated citations (about 2000 on D and D) and a database of 1800 contacts involved with remedial action work at radioactively contaminated sites; publishing an annual bibliography, ''Nuclear Facility Decommissioning and Site Remedial Actions, A Selected Bibliography,'' ORNL/EIS-154 (six volumes published); maintaining a document repository and providing copies of requested publications; and performing manual and computerized searches of the technical literature. The most significant RAPIC function is serving as a focal point for D and D information. With the extensive resources at its command, RAPIC is in a unique position to provide a comprehensive information base to the D and D community. DOE makes these services available to foster good public relations and promote cooperation and information exchange

  8. Decontamination of the RA reactor heavy water system, Annex 9

    International Nuclear Information System (INIS)

    Maksimovic, Z.B.; Nikolic, R.M.; Marinkovic, M.D.; Jelic, Lj.M.

    1963-01-01

    Both stainless steel and aluminium parts of the RA reactor heavy water system system were decontaminated as well as the heavy water itself. System was contaminated with 60 Co. Decontamination factor was determined by activity measurements during distillation. Concentration of the corrosion products in the heavy water was measured by spectrochemical analysis, and found to be 0.1 - 1 mg/l. Chemical analyses of the aluminium and stainless steel surfaces showed that cobalt was adsorbed on the aluminium oxide layer. Water solution of 7%H 3 PO 4 + 2% CrO 3 was used for decontamination of the heavy water system and distillation device. This was found to be the most efficient solvent which does not affect stainless steel corrosion. Decontamination factors achieved were from 60 - 100. Decontamination results enabled determining the distribution of cobalt in the system: 10 Ci on the stainless steel parts, 50 Ci in the heavy water; and above 600 Ci on the fuel and experimental channels. Specific activity of 60 Co was calculated to be 15 Ci/g on the reactor channels, 8 Ci/g on the stainless steel parts and 3 Ci/g in the heavy water. Decontamination of the aluminium parts was not done because it was considered it could initiate corrosion. Since the efficiency of distillation is increased it was expected that permanent distillation would remove most of the activity in the reactor channels

  9. Deactivating Chemical Agents Using Enzyme-Coated Nanofibers Formed by Electrospinning

    Science.gov (United States)

    2016-01-01

    7.3mM/mg). Key words Coaxial electrospinning, DFPase, Enzyme, chemical warfare , nanofiber, decontamination . Introduction Chemical warfare ...Krile, R.; Nishioka, M.; Taylor, M.; Riggs, K.; Stone, H. Decontamination of Toxic Industrial Chemicals and Chemical Warfare Agents On Building...298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18 MATS COATINGS ELECTROSPINNING CHEMICAL WARFARE

  10. Comparison of skin decontamination efficacy of commercial decontamination products following exposure to VX on human skin.

    Science.gov (United States)

    Thors, L; Koch, M; Wigenstam, E; Koch, B; Hägglund, L; Bucht, A

    2017-08-01

    The decontamination efficacy of four commercially available skin decontamination products following exposure to the nerve agent VX was evaluated in vitro utilizing a diffusion cell and dermatomed human skin. The products included were Reactive Skin Decontamination Lotion (RSDL), the Swedish decontamination powder 104 (PS104), the absorbent Fuller's Earth and the aqueous solution alldecontMED. In addition, various decontamination procedures were assessed to further investigate important mechanisms involved in the specific products, e.g. decontamination removal from skin, physical removal by sponge swabbing and activation of degradation mechanisms. The efficacy of each decontamination product was evaluated 5 or 30 min after dermal application of VX (neat or diluted to 20% in water). The RSDL-lotion was superior in reducing the penetration of VX through human skin, both when exposed as neat agent and when diluted to 20% in water. Swabbing with the RSDL-sponge during 2 min revealed decreased efficacy compared to applying the RSDL-lotion directly on the skin for 30 min. Decontamination with Fuller's Earth and alldecontMED significantly reduced the penetration of neat concentration of VX through human skin. PS104-powder was insufficient for decontamination of VX at both time-points, independently of the skin contact time of PS104. The PS104-slurry (a mixture of PS104-powder and water), slightly improved the decontamination efficacy. Comparing the time-points for initiated decontamination revealed less penetrated VX for RSDL and Fuller's Earth when decontamination was initiated after 5 min compared to 30 min post-exposure, while alldecontMED displayed similar efficacy at both time-points. Decontamination by washing with water only resulted in a significant reduction of penetrated VX when washing was performed 5 min after exposure, but not when decontamination was delayed to 30 min post-exposure of neat VX. In conclusion, early initiated decontamination with the

  11. Hairy skin exposure to VX in vitro: effectiveness of delayed decontamination.

    Science.gov (United States)

    Rolland, P; Bolzinger, M-A; Cruz, C; Josse, D; Briançon, S

    2013-02-01

    The chemical warfare agents such as VX represent a threat for both military and civilians, which involves an immediate need of effective decontamination systems. Since human scalp is usually unprotected compared to other body regions covered with clothes, it could be a preferential site of exposure in case of terrorist acts. The purpose of this study was to determine if skin decontamination could be efficient when performed more than 1h after exposure. In addition, the impact of hairs in skin contamination was investigated. By using in vitro skin models, we demonstrated that about 75% of the applied quantity of VX was recovered on the skin surface 2h after skin exposition, which means that it is worth decontaminating even if contamination occurred 2h before. The stratum corneum reservoir for VX was quickly established and persistent. In addition, the presence of hairs modified the percutaneous penetration of the nerve agent by binding of VX to hairs. Hair shaft has thus to be taken into account in the decontamination process. Reactive Skin Decontamination Lotion (RSDL) and Fuller's Earth (FE) were active in the skin decontamination 45min post-exposure, but RSDL was more efficient in reducing the amount of VX either in the skin or in the hair. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. New sorption-reagent materials for decontamination of liquid radioactive waste

    International Nuclear Information System (INIS)

    Avramenko, V.A.; Golikov, A.P.; Zheleznov, V.V.; Kaplun, E.V.; Marinin, D.V.; Sokolnitskaya, T.A.

    2001-01-01

    Full text: Use of selective sorbents in liquid radioactive waste (LRW) management is widely spread in the field of nuclear power objects liquid waste decontamination, since the main objective there is to remove long-lived radionuclides of the nuclear cycle. The latter include, first of all, cesium-137, strontium-90, cobalt-60 and a number of α-irradiators. In this case LRW composition for most of the nuclear power objects is rather simple, except acidic deactivation solutions. At the same time, liquid radioactive wastes of different research centers have a variable chemical and radiochemical composition depending on objectives and tasks of a given center research activities. As a result, application of sorption technologies in such waste decontamination determines special requirements to these sorbents selectivity: a wide spectrum of radionuclides that can be removed and fairly high selectivity enabling to remove radionuclides from solutions of complex chemical composition (containing surfactants, complexing agents etc.). This paper is concerned with studying properties of new materials selective to different radionuclides. These materials are capable to interact with solution components whether already contained in the waste or deliberately added into resulting solution. Such sorption-reagent materials combine universal character of co-precipitation methods with simplicity of sorption methods. In this work we studied sorption-reagent inorganic ion-exchange materials interacting with sulfate-, carbonate-, oxalate-, sulfide-, and permanganate-ions. Insoluble compounds formed as a result of this interaction increase tens- and hundreds-fold the sorption selectivity of different radionuclides - strontium, cobalt, mercury, iron, and manganese as compared to conventional ion-exchange system. By means of X-ray phase analysis, IR-spectroscopy, chemical and radiochemical analysis, we have studied the mechanism of radionuclide sorption on different sorption

  13. Developmental Testing of Liquid and Gaseous/Vaporous Decontamination on Bacterial Spores and Other Biological Warfare Agents on Military Relevant Surfaces

    Science.gov (United States)

    2016-02-11

    Vaporous Decontamination on Bacterial Spores and Other Biological Warfare Agents on Military-Relevant Surfaces 5a. CONTRACT NUMBER 5b. GRANT... DECONTAMINATION ON BACTERIAL SPORES AND OTHER BIOLOGICAL WARFARE AGENTS ON MILITARY-RELEVANT SURFACES Page Paragraph 1. SCOPE...surfaces before and after decontamination . The protocol in this TOP is based on the developed test methodologies from Edgewood Chemical Biological

  14. Development of a mobile unit for 'in loco' sistematic decontamination in nuclear power plants components

    International Nuclear Information System (INIS)

    Camargo, G.A.M.

    1986-01-01

    A mobile decontamination unit was developed to perform 'in situ' decontamination of tanks and pressure vessels belonging to the reactor auxiliary and ancillary systems. The whole system, including a control desk, is assembled in 6 trolleys which can be moved inside the plant, thus enabling component decontamination by injecting demineralized water at a pressure of approx. 50 bar and temperatures up to 90 0 , with or without chemical additives. Considering the versatility and easy handling demonstrated after extensive testing, this new system shall be used in Angra 2 and 3. (Author) [pt

  15. Research and development for decontamination system of spent resin in Hanbit Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Gi Hong [Dept. of Nuclear Engineering, Chosun University, Gwangju (Korea, Republic of)

    2015-12-15

    When reactor coolant leaks occur due to cracks of a steam generator tube, radioactive materials contained in the primary cooling water in nuclear power plant are forced out toward the secondary systems. At this time the secondary water purification resin in the ion exchange resin tower of the steam generator blowdown system is contaminated by the radioactivity of the leaked radioactive materials, so we pack this in special containers and store temporarily because we could not dispose it by ourselves. If steam generator tube leakage occurs, it produces contaminated spent resins annually about 5,000-7,000 liters. This may increase the amount of nuclear waste productions, a disposal working cost and a unit price of generating electricity in the plant. For this reasons, it is required to develop a decontamination process technique for reducing the radioactive level of these resins enough to handle by the self-disposal method. In this research, First, Investigated the structure and properties of the ion exchange resin used in a steam generator blowdown system. Second, Checked for a occurrence status of contaminated spent resin and a disposal technology. Third, identified the chemical characteristics of the waste radionuclides of the spent resin, and examined ionic bonding and separation mechanism of radioactive nuclear species and a spent resin. Finally, we carried out the decontamination experiment using chemicals, ultrasound, microbubbles, supercritical carbon dioxide to process these spent resin. In the case of the spent resin decontamination method using chemicals, the higher the concentration of the drug decontamination efficiency was higher. In the ultrasound method, foreign matter of the spent resin was removed and was found that the level of radioactivity is below of the MDA. In the microbubbles method, we found that the concentration of the radioactivity decreased after the experiment, so it can be used to the decontamination process of the spent resin. In

  16. Research and development for decontamination system of spent resin in Hanbit Nuclear Power Plant

    International Nuclear Information System (INIS)

    Sung, Gi Hong

    2015-01-01

    When reactor coolant leaks occur due to cracks of a steam generator tube, radioactive materials contained in the primary cooling water in nuclear power plant are forced out toward the secondary systems. At this time the secondary water purification resin in the ion exchange resin tower of the steam generator blowdown system is contaminated by the radioactivity of the leaked radioactive materials, so we pack this in special containers and store temporarily because we could not dispose it by ourselves. If steam generator tube leakage occurs, it produces contaminated spent resins annually about 5,000-7,000 liters. This may increase the amount of nuclear waste productions, a disposal working cost and a unit price of generating electricity in the plant. For this reasons, it is required to develop a decontamination process technique for reducing the radioactive level of these resins enough to handle by the self-disposal method. In this research, First, Investigated the structure and properties of the ion exchange resin used in a steam generator blowdown system. Second, Checked for a occurrence status of contaminated spent resin and a disposal technology. Third, identified the chemical characteristics of the waste radionuclides of the spent resin, and examined ionic bonding and separation mechanism of radioactive nuclear species and a spent resin. Finally, we carried out the decontamination experiment using chemicals, ultrasound, microbubbles, supercritical carbon dioxide to process these spent resin. In the case of the spent resin decontamination method using chemicals, the higher the concentration of the drug decontamination efficiency was higher. In the ultrasound method, foreign matter of the spent resin was removed and was found that the level of radioactivity is below of the MDA. In the microbubbles method, we found that the concentration of the radioactivity decreased after the experiment, so it can be used to the decontamination process of the spent resin. In

  17. Separations canyon decontamination facilities

    International Nuclear Information System (INIS)

    Hershey, J.H.

    1975-01-01

    Highly radioactive process equipment is decontaminated at the Savannah River Plant in specially equipped areas of the separations canyon building so that direct mechanical repairs or alterations can be made. Using these facilities it is possible to decontaminate and repair equipment such as 10- x 11-ft storage tanks, 8- x 8-ft batch evaporator pots and columns, 40-in. Bird centrifuges, canyon pumps and agitators, and various canyon piping systems or ''jumpers.'' For example, centrifuge or evaporator pots can be decontaminated and rebuilt for about 60 percent of the 1974 replacement cost. The combined facilities can decontaminate and repair 6 to 10 pieces of major equipment per year. Decontamination time varies with type of equipment and radioactivity levels encountered

  18. Separations canyon decontamination facilities

    International Nuclear Information System (INIS)

    Hershey, J.H.

    1975-05-01

    Highly radioactive process equipment is decontaminated at the Savannah River Plant in specially equipped areas of the separations canyon buildings so that direct mechanical repairs or alterations can be made. Using these facilities it is possible to decontaminate and repair equipment such as 10- x 11-ft storage tanks, 8- x 8-ft batch evaporator pots and columns, 40-in. Bird centrifuges, canyon pumps and agitators, and various canyon piping systems or ''jumpers.'' For example, centrifuge or evaporator pots can be decontaminated and rebuilt for about 60 percent of the 1974 replacement cost. The combined facilities can decontaminate and repair 6 to 10 pieces of major equipment per year. Decontamination time varies with type of equipment and radioactivity levels encountered. (U.S.)

  19. Volunteer trials of a novel improvised dry decontamination protocol for use during mass casualty incidents as part of the UK'S Initial Operational Response (IOR.

    Directory of Open Access Journals (Sweden)

    Richard Amlôt

    Full Text Available Previous studies have demonstrated that rapid evacuation, disrobing and emergency decontamination can enhance the ability of emergency services and acute hospitals to effectively manage chemically-contaminated casualties. The purpose of this human volunteer study was to further optimise such an "Initial Operational Response" by (1 identifying an appropriate method for performing improvised skin decontamination and (2 providing guidance for use by first responders and casualties. The study was performed using two readily available, absorbent materials (paper towels and incontinence pads. The decontamination effectiveness of the test materials was measured by quantifying the amount of a chemical warfare agent simulant (methyl salicylate removed from each volunteer's forearm skin. Results from the first study demonstrated that simulant recovery was lower in all of the dry decontamination conditions when compared to matched controls, suggesting that dry decontamination serves to reduce chemical exposure. Blotting in combination with rubbing was the most effective form of decontamination. There was no difference in effectiveness between the two absorbent materials. In the following study, volunteers performed improvised dry decontamination, either with or without draft guidelines. Volunteers who received the guidance were able to carry out improvised dry decontamination more effectively, using more of the absorbent product (blue roll to ensure that all areas of the body were decontaminated and avoiding cross-contamination of other body areas by working systematically from the head downwards. Collectively, these two studies suggest that absorbent products that are available on ambulances and in acute healthcare settings may have generic applicability for improvised dry decontamination. Wherever possible, emergency responders and healthcare workers should guide casualties through decontamination steps; in the absence of explicit guidance and

  20. Volunteer trials of a novel improvised dry decontamination protocol for use during mass casualty incidents as part of the UK'S Initial Operational Response (IOR).

    Science.gov (United States)

    Amlôt, Richard; Carter, Holly; Riddle, Lorna; Larner, Joanne; Chilcott, Robert P

    2017-01-01

    Previous studies have demonstrated that rapid evacuation, disrobing and emergency decontamination can enhance the ability of emergency services and acute hospitals to effectively manage chemically-contaminated casualties. The purpose of this human volunteer study was to further optimise such an "Initial Operational Response" by (1) identifying an appropriate method for performing improvised skin decontamination and (2) providing guidance for use by first responders and casualties. The study was performed using two readily available, absorbent materials (paper towels and incontinence pads). The decontamination effectiveness of the test materials was measured by quantifying the amount of a chemical warfare agent simulant (methyl salicylate) removed from each volunteer's forearm skin. Results from the first study demonstrated that simulant recovery was lower in all of the dry decontamination conditions when compared to matched controls, suggesting that dry decontamination serves to reduce chemical exposure. Blotting in combination with rubbing was the most effective form of decontamination. There was no difference in effectiveness between the two absorbent materials. In the following study, volunteers performed improvised dry decontamination, either with or without draft guidelines. Volunteers who received the guidance were able to carry out improvised dry decontamination more effectively, using more of the absorbent product (blue roll) to ensure that all areas of the body were decontaminated and avoiding cross-contamination of other body areas by working systematically from the head downwards. Collectively, these two studies suggest that absorbent products that are available on ambulances and in acute healthcare settings may have generic applicability for improvised dry decontamination. Wherever possible, emergency responders and healthcare workers should guide casualties through decontamination steps; in the absence of explicit guidance and instructions, improvised

  1. Zirconium Hydroxide-coated Nanofiber Mats for Nerve Agent Decontamination.

    Science.gov (United States)

    Kim, Sohee; Ying, Wu Bin; Jung, Hyunsook; Ryu, Sam Gon; Lee, Bumjae; Lee, Kyung Jin

    2017-03-16

    Diverse innovative fabrics with specific functionalities have been developed for requirements such as self-decontamination of chemical/biological pollutants and toxic nerve agents. In this work, Zr(OH) 4 -coated nylon-6,6 nanofiber mats were fabricated for the decontamination of nerve agents. Nylon-6,6 fabric was prepared via the electrospinning process, followed by coating with Zr(OH) 4 , which was obtained by the hydrolysis of Zr(OBu) 4 by a sol-gel reaction on nanofiber surfaces. The reaction conditions were optimized by varying the amounts of Zr(OBu) 4 ,the reaction time, and the temperature of the sol-gel reaction. The composite nanofibers show high decontamination efficiency against diisopropylfluorophosphate, which is a nerve agent analogue, due to its high nucleophilicity that aids in the catalysis of the hydrolysis of the phosphonate ester bonds. Composite nanofiber mats have a large potential and can be applied in specific fields such as military and medical markets. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Dwell time considerations for large area cold plasma decontamination

    Science.gov (United States)

    Konesky, Gregory

    2009-05-01

    Atmospheric discharge cold plasmas have been shown to be effective in the reduction of pathogenic bacteria and spores and in the decontamination of simulated chemical warfare agents, without the generation of toxic or harmful by-products. Cold plasmas may also be useful in assisting cleanup of radiological "dirty bombs." For practical applications in realistic scenarios, the plasma applicator must have both a large area of coverage, and a reasonably short dwell time. However, the literature contains a wide range of reported dwell times, from a few seconds to several minutes, needed to achieve a given level of reduction. This is largely due to different experimental conditions, and especially, different methods of generating the decontaminating plasma. We consider these different approaches and attempt to draw equivalencies among them, and use this to develop requirements for a practical, field-deployable plasma decontamination system. A plasma applicator with 12 square inches area and integral high voltage, high frequency generator is described.

  3. Decontamination of steam generators at Loviisa NPS - The decision making and the results

    International Nuclear Information System (INIS)

    Wahlstroem, Bjoern G.

    1984-01-01

    In 1980, during the annual inspections at Loviisa 1, 440 MWe PWR unit, some minor faults in the welding seams of the water chambers in two of the six steam generators were indicated. This led to enlarged inspection work and to thousands of working hours inside the steam generators. The plant had been three years in operation, so the dose rates in the steam generators were rather high. In this case it turned out, that a formal radiation protection optimization procedure would not give the answer on how to go ahead, as there were several practical and psychological factors influencing the decision making process. Anyhow, the result was that a decontamination apparatus was urgently planned and constructed, and advice on tested decontamination chemicals was received from the plant supplier. Using the decontamination machine with alternating basic and acid solutions, a decontamination factor of DF = 300 was reached, and the repair work could be performed without any restrictions on working time. This paper points out some limiting factors in the decision making process and describes the decontamination equipment, the decontamination solutions and the programme. The cost per saved collective dose unit is also calculated. (author)

  4. Texas market profile: soil and groundwater decontamination sector

    International Nuclear Information System (INIS)

    1998-12-01

    The soil and groundwater decontamination market in Texas generated $7 billion in earnings in 1997 and should reach almost $9 billion in 2002. While Texas has introduced voluntary clean-up programs, decontamination is required at more than 200,000 sites. Pollution has arisen from such industrial sectors as chemicals, crude oil and natural gas. In Texas, government agency decontamination activities provide major business opportunities. As in the base of the environmental sector as a whole, economic factors are gradually taking over from regulation as the prime demand drivers. Cost and risk are major concerns for clients. Because the incentive to reduce costs and the trend toward contracting out and privatization are becoming stronger, companies with specialized technologies have opportunities in this market. The government is the main client for environmental restoration services, but the private sector is accounting for an increased share of the market. Aspects of market access discussed include: implications of NAFTA and 'Buy America', ATA carnets, the Environmental Technology Verification Program, centralized database, federal government contracting announcements, partnerships, and payment conditions

  5. Decontamination of radioactive contaminated protective wear using dry cleaning solvent

    International Nuclear Information System (INIS)

    Muthiah, Pushpa; Chitra, S.; Paul, Biplob

    2013-01-01

    Liquid waste generated by conventional decontamination of radioactive contaminated cotton protective wear using detergent affects the chemical treatment of the plant. To reduce the generation of aqueous detergent waste, dry cleaning of cotton protective wear, highly soiled with oil and grease towards decontamination was tried with organic solvents. Mineral turpentine oil (MTO) among various other organic solvents was identified as a suitable organic solvent. As MTO leaves characteristic odour on the cloth, various commercial fragrances for the removal of the odour were tried. Application of the optimised dry cleaning solvent and commercial fragrance was adopted in plant scale operation. (author)

  6. Safety analysis report. Decontamination and decommissioning of the EBR-I Complex

    International Nuclear Information System (INIS)

    Commander, J.C.; Macbeth, P.J.; Michels, D.E.

    1975-06-01

    The safety aspects of the planned EBR-I Complex decontamination and decommissioning operations are assessed. The major operations are: (1) removal of NaK from the EBR-I primary and secondary coolant systems, (2) processing of the NaK to produce solid caustic for disposal, (3) decontamination of contaminated areas of EBR-I and ZPR-III, (4) removal of items that cannot be decontaminated economically to acceptably safe levels, (5) isolation of contaminated areas, (6) demolition of the AFSR Shielding, and (7) removal of contaminated vessels from the NaK storage pit. It may be concluded that although potential hazards do exist from explosion, chemical burns and low-level radioactive exposure from the D and D operation, these hazards represent acceptable risks provided that the established procedures and precautions are followed. (U.S.)

  7. Decontamination of radioisotope production facility

    International Nuclear Information System (INIS)

    Daryoko, M.; Yatim, S.; Suseno, H.; Wiratmo, M.

    1998-01-01

    The strippable coating method use phosphoric glycerol and irradiated latex as supporting agents have been investigated. The investigation used some decontaminating agents: EDTA, citric acid, oxalic acid and potassium permanganate were combined with phosphoric glycerol supporting agent, then EDTA Na 2 , sodium citric, sodium oxalic and potassium permanganate were combined with irradiated latex supporting agent. The study was needed to obtain the representative operating data, will be implemented to decontamination the Hot Cell for radioisotope production. The experiment used 50x50x1 mm stainless steel samples and contaminated by Cs-137 about 1.1x10 -3 μCi/cm 2 . This samples according to inner cover of Hot Cell material, and Hot Cell activities. The decontamination factor results of the investigation were: phosphoric glycerol as supporting agent, about 20 (EDTA as decontaminating agent) to 47 (oxalic acid as decontaminating agent), and irradiated latex as supporting agent, about 11.5 (without decontamination agent) to 27 (KMnO 4 as decontaminating agent). All composition of the investigation have been obtained the good results, and can be implemented for decontamination of Hot Cell for radioisotope production. The irradiated latex could be recommended as supporting agent without decontaminating agent, because it is very easy to operate and very cheap cost. (author)

  8. Decontamination of medical radioisotopes from hard surfaces using peelable polymer-based decontamination agents

    International Nuclear Information System (INIS)

    Draine, Amanda E.; Walter, Ken J.; Johnson, Thomas E.

    2008-01-01

    Full text: Medical radioisotopes used to treat and diagnose patients often contaminate surfaces in patient treatment rooms. They are typically short-lived and decay within a matter of days or weeks. However, down time in a medical facility related to radioisotope contamination is costly and can impact patient care. Most liquid or solid spills can be contained and disposed in radioactive wastes fairly completely and quickly; however residual contamination may remain on the contacted surface. Although liquid decontamination agents can be used to address the issue of residual contamination, they often require multiple applications with attendant scrubbing and wiping. Liquid decontamination can also produce large volumes of low-level radioactive waste. To look at reducing radioactive waste volumes, research was conducted on the efficacy of three low-volume peel able decontamination agents. Testing was performed on hard surfaces, such as vinyl composition floor tiles and stainless steel, which are found in many hospitals, research laboratories, and universities. The tiles were contaminated with the medical use isotopes of 99m Tc, Tl-201, and I-131 and subsequently decontaminated with one of the three decontamination agents. Quantitative and qualitative data were obtained for each of three different peel able decontamination agent formulations. Quantitative data included environmental temperature and relative humidity, application thickness, dry time, contact time, and decontamination efficacy of the agents on the tested surfaces. Qualitative factors included ease of application and pee lability, as well as sag resistance and odor of each agent. Initial studies showed that under standard conditions there were reproducible differences in the decontamination efficacies among the three different decontamination formulations. (author)

  9. Decontamination formulation with sorbent additive

    Science.gov (United States)

    Tucker; Mark D. , Comstock; Robert H.

    2007-10-16

    A decontamination formulation and method of making that neutralizes the adverse health effects of both chemical and biological compounds, especially chemical warfare (CW) and biological warfare (BW) agents, and toxic industrial chemicals. The formulation provides solubilizing compounds that serve to effectively render the chemical and biological compounds, particularly CW and BW compounds, susceptible to attack, and at least one reactive compound that serves to attack (and detoxify or kill) the compound. The formulation includes at least one solubilizing agent, a reactive compound, a bleaching activator, a sorbent additive, and water. The highly adsorbent, water-soluble sorbent additive (e.g., sorbitol or mannitol) is used to "dry out" one or more liquid ingredients, such as the liquid bleaching activator (e.g., propylene glycol diacetate or glycerol diacetate) and convert the activator into a dry, free-flowing powder that has an extended shelf life, and is more convenient to handle and mix in the field.

  10. Bioinspired Surface Treatments for Improved Decontamination: Handling andDecontamination Considerations

    Science.gov (United States)

    2018-03-16

    and Decontamination Considerations Brandy J. White Martin H. Moore Brian J. Melde Laboratory for the Study of Molecular Interfacial Interactions...Decontamination Considerations Brandy J. White, Martin H. Moore, Brian J. Melde, Anthony P. Malanoksi, and Chanté Campbell1 Center for Bio/Molecular

  11. Fighting Ebola with novel spore decontamination technologies for the military.

    Science.gov (United States)

    Doona, Christopher J; Feeherry, Florence E; Kustin, Kenneth; Olinger, Gene G; Setlow, Peter; Malkin, Alexander J; Leighton, Terrance

    2015-01-01

    Recently, global public health organizations such as Doctors without Borders (MSF), the World Health Organization (WHO), Public Health Canada, National Institutes of Health (NIH), and the U.S. government developed and deployed Field Decontamination Kits (FDKs), a novel, lightweight, compact, reusable decontamination technology to sterilize Ebola-contaminated medical devices at remote clinical sites lacking infra-structure in crisis-stricken regions of West Africa (medical waste materials are placed in bags and burned). The basis for effectuating sterilization with FDKs is chlorine dioxide (ClO2) produced from a patented invention developed by researchers at the US Army Natick Soldier RD&E Center (NSRDEC) and commercialized as a dry mixed-chemical for bacterial spore decontamination. In fact, the NSRDEC research scientists developed an ensemble of ClO2 technologies designed for different applications in decontaminating fresh produce; food contact and handling surfaces; personal protective equipment; textiles used in clothing, uniforms, tents, and shelters; graywater recycling; airplanes; surgical instruments; and hard surfaces in latrines, laundries, and deployable medical facilities. These examples demonstrate the far-reaching impact, adaptability, and versatility of these innovative technologies. We present herein the unique attributes of NSRDEC's novel decontamination technologies and a Case Study of the development of FDKs that were deployed in West Africa by international public health organizations to sterilize Ebola-contaminated medical equipment. FDKs use bacterial spores as indicators of sterility. We review the properties and structures of spores and the mechanisms of bacterial spore inactivation by ClO2. We also review mechanisms of bacterial spore inactivation by novel, emerging, and established non-thermal technologies for food preservation, such as high pressure processing, irradiation, cold plasma, and chemical sanitizers, using an array of Bacillus

  12. Eurochemic reprocessing plant decommissioning. Decontamination of contaminated metal

    International Nuclear Information System (INIS)

    Walthery, R.; Teunckens, L.; Lewandowski, P.

    1998-01-01

    When decommissioning nuclear installations, large quantifies of metal components are produced as well as significant amounts of other radioactive materials, which mostly show low surface contamination. Having been used or having been brought for a while in a controlled area, marks them as 'suspected material'. In view of the very high costs for radioactive waste processing and disposal, alternatives have been considered, and much effort has been spent in recycling through decontamination, melting and unconditional release of metals. In a broader context, recycling of materials can be considered as a first order ecological priority to limit the quantities of radioactive wastes to be disposed of, to reduce the technical and economic problems involved with the management of radioactive wastes, and to make economic use of primary material and conserve natural resources of basic material for future generations. Other evaluations as the environmental impact of recycling compared to non recycling (mining or production of new material) and waste treatment, with the associated risks involved, can also be considered, as well as social and political impacts of recycling. This document gives an overview of the current practices in recycling of materials at the decommissioning of the Eurochemic reprocessing plant in Dessel, Belgium. It deals with the decontamination and measurement techniques in use, and considers related technical and economic aspects and constraints. (author)

  13. Analysis of the application of decontamination technologies to radioactive metal waste minimization using expert systems

    Energy Technology Data Exchange (ETDEWEB)

    Bayrakal, Suna [Iowa State Univ., Ames, IA (United States)

    1993-09-30

    Radioactive metal waste makes up a significant portion of the waste currently being sent for disposal. Recovery of this metal as a valuable resource is possible through the use of decontamination technologies. Through the development and use of expert systems a comparison can be made of laser decontamination, a technology currently under development at Ames Laboratory, with currently available decontamination technologies for applicability to the types of metal waste being generated and the effectiveness of these versus simply disposing of the waste. These technologies can be technically and economically evaluated by the use of expert systems techniques to provide a waste management decision making tool that generates, given an identified metal waste, waste management recommendations. The user enters waste characteristic information as input and the system then recommends decontamination technologies, determines residual contamination levels and possible waste management strategies, carries out a cost analysis and then ranks, according to cost, the possibilities for management of the waste. The expert system was developed using information from literature and personnel experienced in the use of decontamination technologies and requires validation by human experts and assignment of confidence factors to the knowledge represented within.

  14. Analysis of the application of decontamination technologies to radioactive metal waste minimization using expert systems

    International Nuclear Information System (INIS)

    Bayrakal, S.

    1993-01-01

    Radioactive metal waste makes up a significant portion of the waste currently being sent for disposal. Recovery of this metal as a valuable resource is possible through the use of decontamination technologies. Through the development and use of expert systems a comparison can be made of laser decontamination, a technology currently under development at Ames Laboratory, with currently available decontamination technologies for applicability to the types of metal waste being generated and the effectiveness of these versus simply disposing of the waste. These technologies can be technically and economically evaluated by the use of expert systems techniques to provide a waste management decision making tool that generates, given an identified metal waste, waste management recommendations. The user enters waste characteristic information as input and the system then recommends decontamination technologies, determines residual contamination levels and possible waste management strategies, carries out a cost analysis and then ranks, according to cost, the possibilities for management of the waste. The expert system was developed using information from literature and personnel experienced in the use of decontamination technologies and requires validation by human experts and assignment of confidence factors to the knowledge represented within

  15. Summary review of Mound Facility's experience in decontamination of concrete

    International Nuclear Information System (INIS)

    Combs, A.B.; Davis, W.P.; Garner, J.M.; Geichman, J.R.

    1980-01-01

    Most of the current concrete decontamination work at Mound Facility involves surfaces that are contaminated with plutonium-238. Approximately 60,000 sq. ft. of concrete floors will have to be decontaminated in Mound's current Decontamination and Decommissioning (D and D) Project. Although most of these surfaces are partially protected by a barrier (tile or paint), contaminated water and acid have penetrated these barriers. The technique for decontaminating these floors is desribed. The initial cleaning of the floor involes standard water and detergent. Acids are not used in cleaning as they tend to drive the contamination deeper into the concrete surface. Next, the floor tile is manually removed inside a temporary enclosure under negative and filtered ventilation. Finally, layers of contaminated concrete are mechanically removed inside the ventilated enclosure. The suspected depth and surface area of contamination determines the type of mechanical tool used. In summary, several generic methods of concrete decontamination can be utilized: chemical, such as water, detergent, acids, paint remover, strippable paints, etc.; rotary using sanders, grinders, scarifiers, etc.; impact such as pressure washers (hydrolasers), particle blasters, scabblers, needlers, spallers, paving and rock breakers, ram hoes, etc. The particular method used depends on several factors: surface and area involved; depth of contamination; cost and availability of equipment; usage safety and radiological control; and waste generated

  16. In vivo decontamination of the nerve agent VX using the domestic swine model.

    Science.gov (United States)

    Misik, Jan; Pavlik, Michal; Novotny, Ladislav; Pavlikova, Ruzena; Chilcott, Robert P; Cabal, Jiri; Kuca, Kamil

    2012-11-01

    The purpose of this in vivo study was to assess a new, putatively optimised method for mass casualty decontamination ("ORCHIDS protocol") for effectiveness in removing the chemical warfare agent VX from the skin of anaesthetised, domestic white pigs. ORCHIDS protocol consists of a 1.5-minute shower with a mild detergent (Argos™) supplemented by physical removal. A standard method of wet decontamination was used for comparison. Experimental animals were divided into four groups (A-D). Two groups were exposed to a supra-lethal percutaneous dose (5 × LD(50); 300 μg kg(-1)) of VX for 1 h prior to decontamination with either the ORCHIDS (C) or standard protocol (D). A third (B, positive control) group was exposed but not subject to decontamination. Blank controls (A) received anaesthesia and the corresponding dose of normal saline instead of VX. Observations of the clinical signs of intoxication were supplemented by measurements of whole blood cholinesterase (ChE) performed on samples of arterial blood acquired at 30-minute intervals for the duration of the study (up to 6 h). Untreated (B) animals displayed typical cholinergic signs consistent with VX intoxication (local fasciculation, mastication, salivation, pilo-erection and motor convulsions) and died 165-240 min post exposure. All animals in both decontamination treatment groups (C, D) survived the duration of the study and exhibited less severe signs of cholinergic poisoning. Thus, both the standard and ORCHIDS protocol were demonstrably effective against exposure to the potent nerve agent VX, even after a delay of 1 h. A critical advantage of the ORCHIDS protocol is the relatively short shower duration (1½ min compared to 3 min). In practice, this could substantially improve the rate at which individuals could be decontaminated by emergency responders following exposure to toxic materials such as chemical warfare agents.

  17. Cutaneous challenge with chemical warfare agents in the SKH-1 hairless mouse (II): effects of some currently used skin decontaminants (RSDL and Fuller's earth) against liquid sulphur mustard and VX exposure.

    Science.gov (United States)

    Taysse, L; Dorandeu, F; Daulon, S; Foquin, A; Perrier, N; Lallement, G; Breton, P

    2011-06-01

    Using the hairless mouse screening model presented in the companion paper(1) the aim of this study was to assess two skin decontaminating systems: Fuller's earth (FE) and Reactive Skin Decontamination Lotion (RSDL) against two extremely toxic chemical warfare agents that represent a special percutaneous hazard, sulphur mustard (SM) and O-ethyl-S-(2[di-isopropylamino]ethyl)methyl-phosphonothioate (VX). Five minutes after being exposed on the back to either 2 µL of neat sulphur mustard or 50 µg.kg(-1) of diluted VX, mice were decontaminated. Both systems were able to reduce blisters 3 days after SM exposure. However, RSDL was found to be more efficient than FE in reducing the necrosis of the epidermis and erosion. In the case of VX exposure, RSDL, whatever the ratio of decontaminant to toxicant used (RSDL 10, 20, 50), was not able to sufficiently prevent the inhibition of plasma cholinesterases taken as a surrogate marker of exposure and toxicity. Only FE reduced significantly the ChE inhibition. Some of these observations are different from our previous results obtained in domestic swine and these changes are thus discussed in the perspective of using SKH-1 hairless mice for the initial in vivo screening of decontaminants.

  18. Reactive decontamination of absorbing thin film polymer coatings: model development and parameter determination

    Science.gov (United States)

    Varady, Mark; Mantooth, Brent; Pearl, Thomas; Willis, Matthew

    2014-03-01

    A continuum model of reactive decontamination in absorbing polymeric thin film substrates exposed to the chemical warfare agent O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothioate (known as VX) was developed to assess the performance of various decontaminants. Experiments were performed in conjunction with an inverse analysis method to obtain the necessary model parameters. The experiments involved contaminating a substrate with a fixed VX exposure, applying a decontaminant, followed by a time-resolved, liquid phase extraction of the absorbing substrate to measure the residual contaminant by chromatography. Decontamination model parameters were uniquely determined using the Levenberg-Marquardt nonlinear least squares fitting technique to best fit the experimental time evolution of extracted mass. The model was implemented numerically in both a 2D axisymmetric finite element program and a 1D finite difference code, and it was found that the more computationally efficient 1D implementation was sufficiently accurate. The resulting decontamination model provides an accurate quantification of contaminant concentration profile in the material, which is necessary to assess exposure hazards.

  19. Attapulgite, a decontaminating medium, research tool in the radioprotection field

    International Nuclear Information System (INIS)

    Panciatici, G.; Belfiore, A.; Poggianti, M.

    1993-01-01

    Gels based on attapulgite, obtained by mixing attapulgite, a clay, with water or chemicals have been used as decontaminating agents. The method has been optimized through extensive scale laboratory experiments carried out under standard conditions. A wide variety of materials, used in nuclear technologies, and significant radionuclides have been tested. Gels obtained with water only in some cases allow full decontamination, when acids are added to clay, complete contamination removal, is possible except for extreme pHs radionuclides solution and on non-passivated or porous surfaces. The optimized decontaminating technique has successively been set up and applied on materials contaminated by routine or accident. Laboratory scale results have been confirmed through practical use. Process data are reported. This method is simple to perform and requires no special equipment. No liquid radioactive waste arises from the process and the resulting solid waste can be conditioned with cement

  20. Chemical Protection Testing of Sorbent-Based Air Purification Components (APCs)

    Science.gov (United States)

    2016-06-24

    handling and storing the chemical materials of interest. Testing facilities intending to use chemical warfare agents (CWAs) and nontraditional agents...handling, and decontamination capabilities for research, development, test, and evaluation (RDT&E) quantities of chemical agents. Chemical agent...and decontaminated IAW the test plan and all test documentation will be archived. All recoverable chemical test materials will be accounted for and

  1. Volunteer trials of a novel improvised dry decontamination protocol for use during mass casualty incidents as part of the UK’S Initial Operational Response (IOR)

    Science.gov (United States)

    Riddle, Lorna; Larner, Joanne

    2017-01-01

    Previous studies have demonstrated that rapid evacuation, disrobing and emergency decontamination can enhance the ability of emergency services and acute hospitals to effectively manage chemically-contaminated casualties. The purpose of this human volunteer study was to further optimise such an “Initial Operational Response” by (1) identifying an appropriate method for performing improvised skin decontamination and (2) providing guidance for use by first responders and casualties. The study was performed using two readily available, absorbent materials (paper towels and incontinence pads). The decontamination effectiveness of the test materials was measured by quantifying the amount of a chemical warfare agent simulant (methyl salicylate) removed from each volunteer’s forearm skin. Results from the first study demonstrated that simulant recovery was lower in all of the dry decontamination conditions when compared to matched controls, suggesting that dry decontamination serves to reduce chemical exposure. Blotting in combination with rubbing was the most effective form of decontamination. There was no difference in effectiveness between the two absorbent materials. In the following study, volunteers performed improvised dry decontamination, either with or without draft guidelines. Volunteers who received the guidance were able to carry out improvised dry decontamination more effectively, using more of the absorbent product (blue roll) to ensure that all areas of the body were decontaminated and avoiding cross-contamination of other body areas by working systematically from the head downwards. Collectively, these two studies suggest that absorbent products that are available on ambulances and in acute healthcare settings may have generic applicability for improvised dry decontamination. Wherever possible, emergency responders and healthcare workers should guide casualties through decontamination steps; in the absence of explicit guidance and instructions

  2. A state of the art report on the decontamination technology for dry ice blasting

    International Nuclear Information System (INIS)

    Shin, J. M.; Kim, K. H.; Park, J. J.; Lee, H. H.; Yang, M. S.; Nam, S. H.; Kim, M. J.

    2000-05-01

    DUPIC fuel fabrication process is a dry processing technology to manufacture CANDU compatible fuel through a direct reprocessing fabrication process from spent PWR fuel. DUPIC fuel fabrication process consists of the slitting of the spent PWR fuel rods, OREOX processing, homogeneous mixing, pelletizing and sintering. All these processes should be conducted by remote means in a M6 hot cell at IMEF. Since DUPIC fuel fabrication process includes powder handling process of highly radioactive spent fuel, decontamination of highly radioactive particulates from all types of surfaces such as DUPIC fuel manufacturing equipment, hot cell floor, tools is very important to improve the safety of hot cell and reduce the dose exposure to operator, This report describes various technologies for dry ice blasting. It provides the fundamentals of dry ice blasting decontamination and technical review of dry ice blasting on the radioactive decontamination

  3. A state of the art report on the decontamination technology for dry ice blasting

    Energy Technology Data Exchange (ETDEWEB)

    Shin, J M; Kim, K H; Park, J J; Lee, H H; Yang, M S; Nam, S H; Kim, M J

    2000-05-01

    DUPIC fuel fabrication process is a dry processing technology to manufacture CANDU compatible fuel through a direct reprocessing fabrication process from spent PWR fuel. DUPIC fuel fabrication process consists of the slitting of the spent PWR fuel rods, OREOX processing, homogeneous mixing, pelletizing and sintering. All these processes should be conducted by remote means in a M6 hot cell at IMEF. Since DUPIC fuel fabrication process includes powder handling process of highly radioactive spent fuel, decontamination of highly radioactive particulates from all types of surfaces such as DUPIC fuel manufacturing equipment, hot cell floor, tools is very important to improve the safety of hot cell and reduce the dose exposure to operator, This report describes various technologies for dry ice blasting. It provides the fundamentals of dry ice blasting decontamination and technical review of dry ice blasting on the radioactive decontamination.

  4. Verification of wet blasting decontamination technology

    International Nuclear Information System (INIS)

    Matsubara, Sachito; Murayama, Kazunari; Yoshida, Hirohisa; Igei, Shigemitsu; Izumida, Tatsuo

    2013-01-01

    Macoho Co., Ltd. participated in the projects of 'Decontamination Verification Test FY 2011 by the Ministry of the Environment' and 'Decontamination Verification Test FY 2011 by the Cabinet Office.' And we tested verification to use a wet blasting technology for decontamination of rubble and roads contaminated by the accident of Fukushima Daiichi Nuclear Power Plant of the Tokyo Electric Power Company. As a results of the verification test, the wet blasting decontamination technology showed that a decontamination rate became 60-80% for concrete paving, interlocking, dense-grated asphalt pavement when applied to the decontamination of the road. When it was applied to rubble decontamination, a decontamination rate was 50-60% for gravel and approximately 90% for concrete and wood. It was thought that Cs-134 and Cs-137 attached to the fine sludge scraped off from a decontamination object and the sludge was found to be separated from abrasives by wet cyclene classification: the activity concentration of the abrasives is 1/30 or less than the sludge. The result shows that the abrasives can be reused without problems when the wet blasting decontamination technology is used. (author)

  5. New decontamination technologies for environmental applications

    International Nuclear Information System (INIS)

    Allen, R.P.; Arrowsmith, H.W.; McCoy, M.W.

    1981-01-01

    The technologies discussed represent a versatile collection of tools and approaches for environmental decontamination applications. The fixatives provide a means for gaining and maintaining control of large contaminated areas, for decontaminating large surface areas, and for protecting equipment and supplies used in decontamination operations. The other decontamination techniques together provide a method for removing loose surface contamination from almost all classes of materials and surfaces. These techniques should have wide application both as direct decontamination processes and for the cleaning of tools and equipment used in the decontamination operations

  6. DuPont Chemical Vapor Technical Report

    International Nuclear Information System (INIS)

    MOORE, T.L.

    2003-01-01

    DuPont Safety Resources was tasked with reviewing the current chemical vapor control practices and providing preventive recommendations on best commercial techniques to control worker exposures. The increased focus of the tank closure project to meet the 2024 Tri-Party Agreement (TPA) milestones has surfaced concerns among some CH2MHill employees and other interested parties. CH2MHill is committed to providing a safe working environment for employees and desires to safely manage the tank farm operations using appropriate control measures. To address worker concerns, CH2MHill has chartered a ''Chemical Vapors Project'' to integrate the activities of multiple CH2MHill project teams, and solicit the expertise of external resources, including an independent Industrial Hygiene expert panel, a communications consultant, and DuPont Safety Resources. Over a three-month time period, DuPont worked with CH2MHill ESH and Q, Industrial Hygiene, Engineering, and the independent expert panel to perform the assessment. The process included overview presentations, formal interviews, informal discussions, documentation review, and literature review. DuPont Safety Resources concluded that it is highly unlikely that workers in the tank farms are exposed to chemicals above established standards. Additionally, the conventional and radiological chemistry is understood, the inherent chemical hazards are known, and the risk associated with chemical vapor exposure is properly managed. The assessment highlighted management's commitment to addressing chemical vapor hazards and controlling the associated risks. Additionally, we found the Industrial Hygiene staff to be technically competent and well motivated. The tank characterization data resides in a comprehensive database containing the tank chemical compositions and relevant airborne concentrations

  7. Complexing properties of the main organic acids used in decontamination solutions and reactions involved in their degradation or elimination

    International Nuclear Information System (INIS)

    Noel, D.; Kerrec, O.; Lantes, B.; Rosset, R.; Bayri, B.; Desbarres, J.; Jardy, A.

    1994-09-01

    This paper presents a study that, parallel with the industrial development of the decontamination chemical process, has been performed more fundamentally on the chemical properties of used products: degradation reaction during process or after decontamination and during wastes treatment. In particular, results show that the organic compounds used have no interaction with resins during radioactive wastes storage and therefore they do not present leaching risk. (authors). 8 refs., 3 figs., 4 tabs

  8. Non-destructive decontamination of building materials

    Science.gov (United States)

    Holecek, Josef; Otahal, Petr

    2015-11-01

    For nondestructive radiation decontamination of surfaces it is necessary to use varnishes, such as ARGONNE, DG1101, DG1108, etc. This text evaluates the use of manufactured strippable coatings for radiation decontamination. To evaluate decontamination capability of such coatings the following varnishes were selected and subsequently used: AZ 1-700 and AXAL 1807S. The varnishes were tested on different building materials surfaces contaminated by short-term radioisotopes of Na-24 or La-140, in water soluble or water insoluble forms. Decontamination quality was assessed by the decontamination efficiency value, defined as the proportion of removed activity to the applied activity. It was found that decontamination efficiency of both used varnishes depends not only on the form of contaminant, but in the case of application of AXAL 1807S varnish it also depends on the method of its application on the contaminated surface. The values of the decontamination efficiency for AZ1-700 varnish range from 46% for decontamination of a soluble form of the radioisotope from concrete surface to 98% for the decontamination of a soluble form of the radioisotope from ceramic tile surface. The decontamination efficiency values determined for AXAL 1807S varnish range from 48% for decontamination of a soluble form of the radioisotope from concrete surface to 96% for decontamination of an insoluble form of the radioisotope from ceramic tile surface. Comparing these values to the values given for the decontaminating varnishes we can conclude that AXAL 1807S varnish is possible to use on all materials, except highly porous materials, such as plasterboard or breeze blocks, or plastic materials. AZ 1-700 varnish can be used for all dry materials except plasterboard.

  9. Personnel protective equipment total-encapsulating suit decontamination study using shower systems

    International Nuclear Information System (INIS)

    Menkhaus, D.E.

    1991-01-01

    This report documents an experimental evaluation, conducted at the Idaho National Engineering Laboratory, of a shower-based decontamination station for personnel wearing a Level A, total- encapsulating, chemical-protective suit. The decontamination station is used by personnel when egressing a dry, dusty environment contaminated with transuranic radionuclides. This system has the potential to minimize the risk of spreading the contaminants to clean areas. Two types of shower systems were evaluated, a drench shower and a multi-nozzle shower. A total-encapsulating suit, worn by personnel. was contaminated with soil containing 239 Pu. Pre- shower and post-shower contamination samples were collected and visual observations were made to evaluate the ability of the shower system to remove the contaminated dust and to obtain baseline data useful in designing a shower-based personnel decontamination system. 12 figs., 7 tabs

  10. Solid Waste Decontamination by Thermal Desorption and Catalytic Oxidation Methods

    Czech Academy of Sciences Publication Activity Database

    Šolcová, Olga; Topka, Pavel; Soukup, Karel; Jirátová, Květa; Váňová, H.; Kaštánek, František

    2014-01-01

    Roč. 68, č. 9 (2014), s. 1279-1282 ISSN 0366-6352 R&D Projects: GA MPO FR-TI1/059 Institutional support: RVO:67985858 Keywords : thermal desorption * catalytic oxidation * soil decontamination Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 1.468, year: 2014

  11. Large-bore pipe decontamination

    International Nuclear Information System (INIS)

    Ebadian, M.A.

    1998-01-01

    The decontamination and decommissioning (D and D) of 1200 buildings within the US Department of Energy-Office of Environmental Management (DOE-EM) Complex will require the disposition of miles of pipe. The disposition of large-bore pipe, in particular, presents difficulties in the area of decontamination and characterization. The pipe is potentially contaminated internally as well as externally. This situation requires a system capable of decontaminating and characterizing both the inside and outside of the pipe. Current decontamination and characterization systems are not designed for application to this geometry, making the direct disposal of piping systems necessary in many cases. The pipe often creates voids in the disposal cell, which requires the pipe to be cut in half or filled with a grout material. These methods are labor intensive and costly to perform on large volumes of pipe. Direct disposal does not take advantage of recycling, which could provide monetary dividends. To facilitate the decontamination and characterization of large-bore piping and thereby reduce the volume of piping required for disposal, a detailed analysis will be conducted to document the pipe remediation problem set; determine potential technologies to solve this remediation problem set; design and laboratory test potential decontamination and characterization technologies; fabricate a prototype system; provide a cost-benefit analysis of the proposed system; and transfer the technology to industry. This report summarizes the activities performed during fiscal year 1997 and describes the planned activities for fiscal year 1998. Accomplishments for FY97 include the development of the applicable and relevant and appropriate regulations, the screening of decontamination and characterization technologies, and the selection and initial design of the decontamination system

  12. Genotoxicity testing of extracts from aflatoxin-contaminated peanut meal, following chemical decontamination

    NARCIS (Netherlands)

    Hoogenboom, L.A.P.; Polman, Th.H.G.; Neal, G.E.; Verma, A.; Guyomard, C.; Tulliez, J.; Gautier, J.P.; Coker, R.D.; Nagler, M.J.; Heidenreich, E.; Delort-Laval, J.

    2001-01-01

    One of the most important concerns in the decontamination of aflatoxin-containing feed commodities is the safety of the products for food-producing animals and for human consumption of products derived from these animals. A new method, based on the use of florisil and C18 solid phase extraction

  13. BNL Building 650 lead decontamination and treatment feasibility study. Final report

    International Nuclear Information System (INIS)

    Kalb, P.D.; Cowgill, M.G.; Milian, L.W.

    1995-10-01

    Lead has been used extensively at Brookhaven National Laboratory (BNL) for radiation shielding in numerous reactor, accelerator and other research programs. A large inventory of excess lead (estimated at 410,000 kg) in many shapes and sizes is currently being stored. Due to it's toxicity, lead and soluble lead compounds are considered hazardous waste by the Environmental Protection Agency. Through use at BNL, some of the lead has become radioactive, either by contamination of the surface or through activation by neutrons or deuterons. This study was conducted at BNL's Environmental and Waste Technology Center for the BNL Safety and Environmental Protection Division to evaluate feasibility of various treatment options for excess lead currently being stored. The objectives of this effort included investigating potential treatment methods by conducting a review of the literature, developing a means of screening lead waste to determine the radioactive characteristics, examining the feasibility of chemical and physical decontamination technologies, and demonstrating BNL polyethylene macro-encapsulation as a means of treating hazardous or mixed waste lead for disposal. A review and evaluation of the literature indicated that a number of physical and chemical methods are available for decontamination of lead. Many of these techniques have been applied for this purpose with varying degrees of success. Methods that apply mechanical techniques are more appropriate for lead bricks and sheet which contain large smooth surfaces amenable to physical abrasion. Lead wool, turnings, and small irregularly shaped pieces would be treated more effectively by chemical decontamination techniques. Either dry abrasion or wet chemical methods result in production of a secondary mixed waste stream that requires treatment prior to disposal

  14. Decontamination of main coolant pumps

    International Nuclear Information System (INIS)

    Roofthooft, R.

    1988-01-01

    Last year a number of main coolant pumps in Belgian nuclear power plants were decontaminated. A new method has been developed to reduce the time taken for decontamination and the volume of waste to be treated. The method comprises two phases: Oxidation with permanganate in nitric acid and dissolution in oxalic acid. The decontamination of main coolant pumps can now be achieved in less than one day. The decontamination factors attained range between 15 and 150. (orig.) [de

  15. Gentilly 1: decontamination program

    International Nuclear Information System (INIS)

    Le, H.; Denault, P.

    1985-01-01

    The Gentilly 1 station, a 250-MW(e) light-water-cooled and heavy-water-moderated nuclear reactor, is being decommissioned to a static state (variant of stage 1) condition by Atomic Energy of Canada Limited (AECL). The scope of the decontamination program at the Gentilly 1 site includes the fuel pool and associated systems, the decontamination center, the laundry, the feedwater pumps and piping systems, the service building ventilation and drainage systems, and miscellaneous floor and wall areas. After an extensive literature review for acceptable decontamination methods, it was decided that the decontamination equipment used at Gentilly 1 during the program would include a hydrolaser, a scarifier, chipping hammers, a steam cleaner, an ultrasonic bath, and cutting tools. In addition, various foams, acids, detergents, surfactants, and abrasives are used alone and in tandem with the above equipment. This paper highlights the result of these decontaminations, their effectiveness, and the recommendation for future application. The methodology in performing these operations are also presented

  16. Evaluation of Microwave Steam Bags for the Decontamination of Filtering Facepiece Respirators

    Science.gov (United States)

    Fisher, Edward M.; Williams, Jessica L.; Shaffer, Ronald E.

    2011-01-01

    Reusing filtering facepiece respirators (FFRs) has been suggested as a strategy to conserve available supplies for home and healthcare environments during an influenza pandemic. For reuse to be possible, used FFRs must be decontaminated before redonning to reduce the risk of virus transmission; however, there are no approved methods for FFR decontamination. An effective method must reduce the microbial threat, maintain the function of the FFR, and present no residual chemical hazard. The method should be readily available, inexpensive and easily implemented by healthcare workers and the general public. Many of the general decontamination protocols used in healthcare and home settings are unable to address all of the desired qualities of an efficient FFR decontamination protocol. The goal of this study is to evaluate the use of two commercially available steam bags, marketed to the public for disinfecting infant feeding equipment, for FFR decontamination. The FFRs were decontaminated with microwave generated steam following the manufacturers' instructions then evaluated for water absorption and filtration efficiency for up to three steam exposures. Water absorption of the FFR was found to be model specific as FFRs constructed with hydrophilic materials absorbed more water. The steam had little effect on FFR performance as filtration efficiency of the treated FFRs remained above 95%. The decontamination efficacy of the steam bag was assessed using bacteriophage MS2 as a surrogate for a pathogenic virus. The tested steam bags were found to be 99.9% effective for inactivating MS2 on FFRs; however, more research is required to determine the effectiveness against respiratory pathogens. PMID:21525995

  17. Evaluation of microwave steam bags for the decontamination of filtering facepiece respirators.

    Directory of Open Access Journals (Sweden)

    Edward M Fisher

    Full Text Available Reusing filtering facepiece respirators (FFRs has been suggested as a strategy to conserve available supplies for home and healthcare environments during an influenza pandemic. For reuse to be possible, used FFRs must be decontaminated before redonning to reduce the risk of virus transmission; however, there are no approved methods for FFR decontamination. An effective method must reduce the microbial threat, maintain the function of the FFR, and present no residual chemical hazard. The method should be readily available, inexpensive and easily implemented by healthcare workers and the general public. Many of the general decontamination protocols used in healthcare and home settings are unable to address all of the desired qualities of an efficient FFR decontamination protocol. The goal of this study is to evaluate the use of two commercially available steam bags, marketed to the public for disinfecting infant feeding equipment, for FFR decontamination. The FFRs were decontaminated with microwave generated steam following the manufacturers' instructions then evaluated for water absorption and filtration efficiency for up to three steam exposures. Water absorption of the FFR was found to be model specific as FFRs constructed with hydrophilic materials absorbed more water. The steam had little effect on FFR performance as filtration efficiency of the treated FFRs remained above 95%. The decontamination efficacy of the steam bag was assessed using bacteriophage MS2 as a surrogate for a pathogenic virus. The tested steam bags were found to be 99.9% effective for inactivating MS2 on FFRs; however, more research is required to determine the effectiveness against respiratory pathogens.

  18. Skin decontamination efficacy of potassium ketoxime on rabbits exposed to sulfur mustard.

    Science.gov (United States)

    Sun, Jing-Hai; Sun, Pei-Pei; Zheng, Wei; Han, Song; Ying, Ying; Liu, Hong-Yan; Zhang, Cheng; Zhao, Bao-Quan; Zuo, Guo-Min; Lu, Hong; Zhong, Yu-Xu

    2015-03-01

    The chemical weapon sulfur mustard (SM) is a blister agent, and currently, there is no effective antidote. To evaluate the decontamination efficacy of potassium ketoxime against SM and preliminarily elucidate its decontamination mechanism. Potassium ketoxime reacted with SM, and SM residues were tested at different time intervals by T-135 colorimetry after the reaction. Rabbit skin was topically exposed to 2 mg/cm(2) SM, treated with potassium ketoxime 1 min later, and observed after 6, 12, and 24 h. Gas chromatography-mass spectroscopy was employed to screen and identify the main products of potassium ketoxime decontamination of SM. Potassium ketoxime had a great effect against SM contamination. With a mass ratio of decontaminant: SM of 50:1, decontamination rates against SM were 87.5% after 30 s, 95.9% after 1 min, and 99.0% after 5 min. Fifteen minutes after exposure to SM, the untreated group showed clear erythema lesions, whereas the experimental group showed no clear erythema lesions within 6 h. After 12 and 24 h, the areas of damaged skin in the experimental group were 0.038 and 0.125 cm(2), respectively, compared with 2.21 and 2.65 cm(2) in the control group. Histopathological analysis revealed that treatment with potassium ketoxime also reduced inflammation-induced damage. The results of this study indicate that potassium ketoxime reacted rapidly and completely with SM, and thus, it was found to be a suitable and effective skin decontaminant against SM. The decontamination reaction mechanism is mainly related to nucleophilic substitution.

  19. Indian experience with radionuclide transport, deposition and decontamination in water-cooled nuclear power reactors

    International Nuclear Information System (INIS)

    Narasimhan, S.V.; Das, P.C.; Lawrence, D.A.; Mathur, P.K.; Venkateswarlu, K.S.

    1983-01-01

    The present generation of water-cooled nuclear reactors uses construction materials chosen with utmost care so that minimum corrosion occurs during the life of the reactor. As interaction between the primary coolant and the construction materials is unavoidable, the coolant is chemically treated to achieve maximum compatibility. First measurements of the chemical and radiochemical composition of the crud present on the in-core and out-of-core primary heat transport system surfaces of a pressurized heavy-water-moderated and cooled reactor (PHWR) are given; then experience in India in the development of a low temperature, one-stage decontaminating formulation for chemical decontamination of the radioactive deposits formed on stainless steel surfaces under BWR conditions is discussed. The effect of the magnitude of the transients in parameters such as reactor power, system temperature, dissolved oxygen content in the coolant, etc. on the nature and migration behaviour of primary heat transport system crud in a PHWR is described. Contributions to radioactive sources and insoluble crud from different primary heat transport system materials are identified and correlated with reactor operations in a PHWR. Man-rem problems faced by nuclear reactors, especially during off-line maintenance, stress the need for reducing the deposited radioactive sources from system surfaces which would otherwise be accessible. Laboratory and on-site experimentation was carried out to effect chemical decontamination on the radioactive deposits formed on the stainless steel surfaces under BWR conditions. Both the reducing and oxidizing formulations were subsequently used in a small-scale, in-plant trial in the clean-up system of a BWR. More than 85% of the deposited 60 Co activity was found to have been removed by the oxidizing formulation. Efforts to develop a decontaminating mixture containing a reducing agent with the help of a circulating loop are in progress in the laboratory. (author)

  20. Decontamination Options for Drinking Water Contaminated with Bacillus anthracis Spores

    Energy Technology Data Exchange (ETDEWEB)

    Raber, E; Burklund, A

    2010-02-16

    Five parameters were evaluated with surrogates of Bacillus anthracis spores to determine effective decontamination options for use in a contaminated drinking water supply. The parameters were: (1) type of Bacillus spore surrogate (B. thuringiensis or B. atrophaeus); (2) spore concentration in suspension (10{sup 2} to 10{sup 6} spores/ml); (3) chemical characteristics of decontaminant [sodium dicholor-s-triazinetrione dihydrate (Dichlor), hydrogen peroxide, potassium peroxymonosulfate (Oxone), sodium hypochlorite, and VirkonS{reg_sign}]; (4) decontaminant concentration (0.01% to 5%); and (5) decontaminant exposure time (10 min to 24 hr). Results from 162 suspension tests with appropriate controls are reported. Hydrogen peroxide at a concentration of 5%, and Dichlor and sodium hypochlorite at a concentration of 2%, were effective at spore inactivation regardless of spore type tested, spore exposure time, or spore concentration evaluated. This is the first reported study of Dichlor as an effective decontaminant for B. anthracis spore surrogates. Dichlor's desirable characteristics of high oxidation potential, high level of free chlorine, and more neutral pH than that of other oxidizers evaluated appear to make it an excellent alternative. All three oxidizers were effective against B. atrophaeus spores in meeting EPA's biocide standard of greater than a 6 log kill after a 10-minute exposure time and at lower concentrations than typically reported for biocide use. Solutions of 5% VirkonS{reg_sign} and Oxone were less effective decontaminants than other options evaluated in this study and did not meet the EPA's efficacy standard for biocides. Differences in methods and procedures reported by other investigators make quantitative comparisons among studies difficult.

  1. Chemical decontamination of radioactive waste

    International Nuclear Information System (INIS)

    Mohamed, H.I.

    2006-01-01

    Radioactive wastes are generated in a number of different kinds of facilities and arise in a wide range of concentrations of radioactive materials and in a variety of physical and chemical forms. There is also a variety of alternatives for treatment and conditioning of the wastes prior disposal. The importance of treatment of radioactive waste for protection of human and environment has long been recognized and considerable experience has gained in this field. Generally, the methods used for treatment of radioactive wastes can be classified into three type's biological, physical and chemical treatment this physical treatment it gives good result than biological treatment. Chemical treatment is fewer hazards and gives good result compared with biological and physical treatments. Chemical treatment is fewer hazards and gives good result compared with biological and physical treatments. In chemical treatment there are different procedures, solvent extraction, ion exchange, electro dialysis but solvent extraction is best one because high purity can be optioned on the other hand the disadvantage that it is expensive. Beside the solvent extraction technique one can be used is ion exchange which gives reasonable result, but requires pretreatment that to avoid in closing of column by colloidal and large species. Electro dialysis technique gives quite result but less than solvent extraction and ion exchange technique the advantage is a cheep.(Author)

  2. Recommendations for skin decontamination

    International Nuclear Information System (INIS)

    1989-01-01

    Further to the reecommendations for determining the surface contamination of the skin and estimating the radiation exposure of the skin after contamination (SAAS-Mitt--89-16), measures for skin decontamination are recommended. They are necessary if (1) after simple decontamination by means of water, soap and brush without damaging the skin the surface contamination limits are exceeded and the radiation exposure to be expected for the undamaged healthy skin is estimated as to high, and if (2) a wound is contaminated. To remove skin contaminations, in general universally applicable, non-aggressive decontamination means and methods are sufficient. In special cases, nuclide-specific decontamination is required taking into account the properties of the radioactive substance

  3. Chemical Technology Division annual technical report 1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-06-01

    The Chemical Technology (CMT) Division is a diverse technical organization with principal emphases in environmental management and development of advanced energy sources. The Division conducts research and development in three general areas: (1) development of advanced power sources for stationary and transportation applications and for consumer electronics, (2) management of high-level and low-level nuclear wastes and hazardous wastes, and (3) electrometallurgical treatment of spent nuclear fuel. The Division also performs basic research in catalytic chemistry involving molecular energy resources, mechanisms of ion transport in lithium battery electrolytes, and the chemistry of technology-relevant materials and electrified interfaces. In addition, the Division operates the Analytical Chemistry Laboratory, which conducts research in analytical chemistry and provides analytical services for programs at Argonne National Laboratory (ANL) and other organizations. Technical highlights of the Division`s activities during 1997 are presented.

  4. 1998 Chemical Technology Division Annual Technical Report.

    Energy Technology Data Exchange (ETDEWEB)

    Ackerman, J.P.; Einziger, R.E.; Gay, E.C.; Green, D.W.; Miller, J.F.

    1999-08-06

    The Chemical Technology (CMT) Division is a diverse technical organization with principal emphases in environmental management and development of advanced energy sources. The Division conducts research and development in three general areas: (1) development of advanced power sources for stationary and transportation applications and for consumer electronics, (2) management of high-level and low-level nuclear wastes and hazardous wastes, and (3) electrometallurgical treatment of spent nuclear fuel. The Division also performs basic research in catalytic chemistry involving molecular energy resources, mechanisms of ion transport in lithium battery electrolytes, and the chemistry of technology-relevant materials. In addition, the Division operates the Analytical Chemistry Laboratory, which conducts research in analytical chemistry and provides analytical services for programs at Argonne National Laboratory (ANL) and other organizations. Technical highlights of the Division's activities during 1998 are presented.

  5. Chemical Technology Division annual technical report 1997

    International Nuclear Information System (INIS)

    1998-06-01

    The Chemical Technology (CMT) Division is a diverse technical organization with principal emphases in environmental management and development of advanced energy sources. The Division conducts research and development in three general areas: (1) development of advanced power sources for stationary and transportation applications and for consumer electronics, (2) management of high-level and low-level nuclear wastes and hazardous wastes, and (3) electrometallurgical treatment of spent nuclear fuel. The Division also performs basic research in catalytic chemistry involving molecular energy resources, mechanisms of ion transport in lithium battery electrolytes, and the chemistry of technology-relevant materials and electrified interfaces. In addition, the Division operates the Analytical Chemistry Laboratory, which conducts research in analytical chemistry and provides analytical services for programs at Argonne National Laboratory (ANL) and other organizations. Technical highlights of the Division's activities during 1997 are presented

  6. Decontamination Data - Blister Agents

    Data.gov (United States)

    U.S. Environmental Protection Agency — Decontamination efficacy data for blister agents on various building materials using various decontamination solutions. This dataset is associated with the following...

  7. Decontamination Systems Information and Research Program: Quarterly report, July--September 1994

    International Nuclear Information System (INIS)

    1994-11-01

    West Virginia University (WVU) and the US DOE Morgantown Energy Technology Center (METC) entered into a Cooperative Agreement on August 29, 1992 entitled ''Decontamination Systems Information and Research Programs'' (DOE Instrument No.: DE-FC21-92MC29467). Stipulated within the Agreement is the requirement that WVU submit to METC a series of Technical Progress Reports on a quarterly basis. This report comprises the eighth Quarterly Technical Progress Report for the Agreement. This report reflects the progress and/or efforts performed on the 16 technical projects encompassed by the Agreement for the period of July 1 through September 30, 1994. These projects focus on the following: Bio-remediation of organic compounds, heavy metals, and radionuclides; miscellaneous remediation technologies; instrumentation; and technology assessments

  8. Microbiological decontamination of natural honey by irradiation

    Science.gov (United States)

    Migdał, W.; Owczarczyk, H. B.; K ȩdzia, B.; Hołderna-K ȩdzia, E.; Madajczyk, D.

    2000-03-01

    Degree of microbiological decontamination, organoleptic and physico-chemical properties of natural honeys were investigated after radiation treatment. Seven kinds of honeys were irradiated with the beams of 10 MeV electrons from a 10 kW linear accelerator "Elektronika 10-10" at the dose 10 kGy. It was shown, that after irradiation, the total count of aerobic and anaerobic bacteria and moulds decrease by 99%. The antibiotic value in investigated honeys increased in turn from 1.67 to 2.67 after irradiation. Such factors and parameters of investigated honeys as their consistency, content of water and saccharose, acidity, the diastase and 5-HMF values were not changed significantly after irradiation. Decontamination by irradiation is a process which allows us to obtain high microbiological purity of honeys. It is especially needed, when honeys are used in surgical treatment of injuries and in nutrition of babies with food deficiency.

  9. Microbiological decontamination of natural honey by irradiation

    International Nuclear Information System (INIS)

    Migdal, W.; Owczarczyk, H.B.; Kedzia, B.; Holderna-Kedzia, E.; Madajczyk, D.

    2000-01-01

    Degree of microbiological decontamination, organoleptic and physico-chemical properties of natural honeys were investigated after radiation treatment. Seven kinds of honeys were irradiated with the beams of 10 MeV electrons from a 10 kW linear accelerator ''Elektronika 10-10'' at the dose 10 kGy. It was shown, that after irradiation, the total count of aerobic and anaerobic bacteria and moulds decrease by 99%. The antibiotic value in investigated honeys increased in turn from 1.67 to 2.67 after irradiation. Such factors and parameters of investigated honeys as their consistency, content of water and saccharose, acidity, the diastase and 5-HMF values were not changed significantly after irradiation. Decontamination by irradiation is a process which allows us to obtain high microbiological purity of honeys. It is especially needed, when honeys are used in surgical treatment of injuries and in nutrition of babies with food deficiency

  10. Lessons learned from decontaminating and decommissioning fuel cycle facilities in France

    International Nuclear Information System (INIS)

    Bordier, Jean-Claude; Dalcorso, J. P.; Nokhamzon, Jean-Guy

    2000-01-01

    This paper draws on 20 years of experience and lessons learned by COGEMA and the CEA during the decontamination and decommissioning (DandD) of its nuclear fuel cycle facilities. COGEMA and the CEA have developed a wealth of knowledge on issues such as assessing decommissioning alternatives, selecting appropriate technical procedures on the basis of thorough site characterization, and developing waste management and disposal procedures. (author)

  11. Potential of Biological Agents in Decontamination of Agricultural Soil

    Directory of Open Access Journals (Sweden)

    Muhammad Kashif Javaid

    2016-01-01

    Full Text Available Pesticides are widely used for the control of weeds, diseases, and pests of cultivated plants all over the world, mainly since the period after the Second World War. The use of pesticides is very extensive to control harm of pests all over the globe. Persistent nature of most of the synthetic pesticides causes serious environmental concerns. Decontamination of these hazardous chemicals is very essential. This review paper elaborates the potential of various biological agents in decontamination of agricultural soils. The agricultural crop fields are contaminated by the periodic applications of pesticides. Biodegradation is an ecofriendly, cost-effective, highly efficient approach compared to the physical and chemical methods which are expensive as well as unfriendly towards environment. Biodegradation is sensitive to the concentration levels of hydrogen peroxide and nitrogen along with microbial community, temperature, and pH changes. Experimental work for optimum conditions at lab scale can provide very fruitful results about specific bacterial, fungal strains. This study revealed an upper hand of bioremediation over physicochemical approaches. Further studies should be carried out to understand mechanisms of biotransformation.

  12. Potential of Biological Agents in Decontamination of Agricultural Soil.

    Science.gov (United States)

    Javaid, Muhammad Kashif; Ashiq, Mehrban; Tahir, Muhammad

    2016-01-01

    Pesticides are widely used for the control of weeds, diseases, and pests of cultivated plants all over the world, mainly since the period after the Second World War. The use of pesticides is very extensive to control harm of pests all over the globe. Persistent nature of most of the synthetic pesticides causes serious environmental concerns. Decontamination of these hazardous chemicals is very essential. This review paper elaborates the potential of various biological agents in decontamination of agricultural soils. The agricultural crop fields are contaminated by the periodic applications of pesticides. Biodegradation is an ecofriendly, cost-effective, highly efficient approach compared to the physical and chemical methods which are expensive as well as unfriendly towards environment. Biodegradation is sensitive to the concentration levels of hydrogen peroxide and nitrogen along with microbial community, temperature, and pH changes. Experimental work for optimum conditions at lab scale can provide very fruitful results about specific bacterial, fungal strains. This study revealed an upper hand of bioremediation over physicochemical approaches. Further studies should be carried out to understand mechanisms of biotransformation.

  13. Decontamination in preparation for dismantlement - AREVA's chemical decontamination technologies, projects performed and results obtained in the period 2011-2016

    International Nuclear Information System (INIS)

    Topf, C.; Sempere Belda, L.

    2017-01-01

    As a consequence of the nuclear phase-out decreed by the German government, several nuclear power plants in the country have already ceased operation. The remaining ones will cease operation by 2022. This has turned Germany into one of the most active regions worldwide in the field of nuclear decommissioning, with new and emerging technologies being deployed on the field, and already preexisting technologies being put to the test, optimized and developed into full maturity. The chemistry services division of AREVA GmbH has already performed 5 Full System Decontaminations (FSD) in preparation for decommissioning in this period - three in PWRs and two in BWRs - along with other international projects of relevance for decommissioning operations. During a FSD, the complete primary circuit of a nuclear power plant including auxiliary systems is subject to a chemical treatment; designed to remove radioactive matter accumulated onto system surfaces during operation. Through the effective removal of this radioactive accumulations contact dose rates on the different components of the primary circuit can be consistently reduced by factors larger than 50. This results in much lower ambient dose rates and, hence, in very significant dose savings for subsequent decommissioning activities. Additionally, dismantlement operations of large components are considerably simplified and can be performed under conditions that wouldn't have been possible before. The project specific objectives and challenges, the technologies employed, and the results obtained are presented and commented here. (authors)

  14. Decontamination systems information and research program. Quarterly report, January 1996--March 1996

    International Nuclear Information System (INIS)

    1996-04-01

    West Virginia University (WVU) and the US Department of Energy, Morgantown Energy Technology Center (DOE/METC) entered into a Cooperative Agreement in August 1992 titled open-quotes Decontamination Systems Information and Research Programsclose quotes (DOE Instrument No.: DE-FC21-92MC29467). Requirements stipulated by the Agreement require WVU to submit quarterly Technical Progress reports. This report contains the efforts of the research projects comprising the Agreement for the 1st calendar quarter of 1996. For the period January 1 through December 31, 1996 twelve projects have been selected for funding, and the Kanawha Valley will continue under a no-cost extension. Three new projects have also been added to the program. This document describes these projects involving decontamination, decommissioning and remedial action issues and technologies

  15. The separation of silica nanoparticle by cetyltrimethylammonium bromide from decontamination foam waste

    International Nuclear Information System (INIS)

    Choi, Man Soo; Yoon, In Ho; Jung, Chong Hun; Moon, Jei Kwon; Choi, Wang Kyu

    2016-01-01

    Decontamination foam has been considered as a potential application for the cleaning of radioactive contaminant in the field of metallic walls, overhead surfaces, and complex components. Moreover, foam decontamination could generate the low secondary waste amount owing to its volume expansion. In order to increase the decontamination efficiency, it is essential to improve the foam stability with low amount of chemical decontamination agent. Yoon et al. reported that the silica nanoparticle containing surfactant increased the foam stability compared to only surfactant solution[3]. Nanoparticle has been used with surfactant, which they adsorb at fluid/fluid interface, to stabilize emulsions or bubbles in foams. Despite of improving foam stability, they still used the surfactant, silica nanoparticle (1 wt%), and viscosifier. In addition, it is difficult to separate silica nanoparticle from decontamination solution. Because nanoparticles differ from classical solid particles due to smaller particle size and their specific properties. Thus, the separation method for nanoparticle should be also developed with high recovery rates. The flocculation of silica nanoparticle added by CTAB could be quickly achieved for only 30 min. The particle size of SiO_2 was larger as CTAB amount increased, and SiO_2 contents in the top solution were decreased after centrifugation

  16. The separation of silica nanoparticle by cetyltrimethylammonium bromide from decontamination foam waste

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Man Soo; Yoon, In Ho; Jung, Chong Hun; Moon, Jei Kwon; Choi, Wang Kyu [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    Decontamination foam has been considered as a potential application for the cleaning of radioactive contaminant in the field of metallic walls, overhead surfaces, and complex components. Moreover, foam decontamination could generate the low secondary waste amount owing to its volume expansion. In order to increase the decontamination efficiency, it is essential to improve the foam stability with low amount of chemical decontamination agent. Yoon et al. reported that the silica nanoparticle containing surfactant increased the foam stability compared to only surfactant solution[3]. Nanoparticle has been used with surfactant, which they adsorb at fluid/fluid interface, to stabilize emulsions or bubbles in foams. Despite of improving foam stability, they still used the surfactant, silica nanoparticle (1 wt%), and viscosifier. In addition, it is difficult to separate silica nanoparticle from decontamination solution. Because nanoparticles differ from classical solid particles due to smaller particle size and their specific properties. Thus, the separation method for nanoparticle should be also developed with high recovery rates. The flocculation of silica nanoparticle added by CTAB could be quickly achieved for only 30 min. The particle size of SiO{sub 2} was larger as CTAB amount increased, and SiO{sub 2} contents in the top solution were decreased after centrifugation.

  17. Archives decontamination by gamma irradiation

    International Nuclear Information System (INIS)

    Bratu, E.; Moise, I.V.; Cutrubinis, M.; Negut, D.C.; Virgolici, Marian

    2009-01-01

    The treatment of archives with gamma irradiation is an efficient and environmental friendly alternative for biological decontamination of large volume of archives. It substitutes the use of chemicals for conservation and contributes to safer workplaces. This work is targeting documents from recent archives where the value of information is not obsolete and may become an important historical and cultural testimony. For a successful treatment, an optimal absorbed dose has to be established. An excessive dose may damage papers and an insufficient one will not reduce bioburden to the desired level. An interdisciplinary team was performing various physical and chemical tests in order to evaluate deterioration of paper at high doses. In the case of natural disaster, it is not excluded the '' emergency '' treatment for documents in immediate danger of total destruction. (authors)

  18. Decontamination of organic waste

    International Nuclear Information System (INIS)

    Schulz, W.

    1977-01-01

    Decontamination stands for the sack collecting of wc-waste water of nuclear-medical tracts and especially the collecting of primary urine and primary faeces of patients after application of radio-isotopes (e.g. iodine 131). They are tied up in the sacks, treated with antiseptic and decomposition-preventing agents, and finally stored in a decupation depot over the time constant. The decupation depot can, for example, be a deep-freezor with separations and clocks, which is radiation-isolated. After the time constant a chemical and/or physical destruction (e.g. comminution) takes place, with simultaneous disinfection and thawing (vapour heating) and the transfer to the canalization. (DG) [de

  19. Development of a suppression method for deposition of radioactive cobalt after chemical decontamination: Confirmation of the Suppression Mechanism with Preoxidized Ferrite Film for Deposition of Radioactive Cobalt

    International Nuclear Information System (INIS)

    Ito, Tsuyoshi; Hosokawa, Hideyuki; Nagase, Makoto; Aizawa, Motohiro; Fuse, Motomasa

    2012-09-01

    Recently, chemical decontamination at the beginning of a periodical inspection is applied to many Japanese boiling water reactor (BWR) plants in order to reduce radiation exposure. In the chemical decontamination, the oxides that have incorporated 60 Co are dissolved using reductive and oxidative chemical reagents. Some of the piping stainless steel (SS) base metal is exposed to the reactor water after this decontamination. The oxide film growth rate of the piping during plant operation just after the decontamination is higher than that just before it. Therefore, there is a possibility that the deposition amount of 60 Co on the piping just after decontamination is higher than that just before the chemical decontamination. The Hi-F Coat (Hitachi ferrite coating) process has been developed to lower recontamination after the chemical decontamination. In this process, a fine Fe 3 O 4 coating film is formed on the piping SS base metal in aqueous solution at 363 K using three chemical reagents: ferrous ion, oxidant, and pH adjuster. The growth rate of the corrosion oxide film that incorporated 60 Co on the piping during plant operation is suppressed by the fine ferrite film that blocks both diffusion of oxidant in the reactor water to the SS base metal and metal ions in the oxide film to the reactor water. As a result, the amount of 60 Co deposition is suppressed by the Hi-F coating film. In a previous report, we found that the Hi-F Coat process lowered the amount of 60 Co to 1/3 that for non-coated specimens. To improve the suppression of 60 Co deposition further, we combined the Hi-F Coat process with a pre-oxidation step which we named the pre-oxidized Hi-F Coat process. In laboratory experiments, using the pre-oxidized Hi-F Coat process we found the deposited amount of 60 Co was 1/10 that for non-coated specimens. By combining the Hi-F Coat process with the pre-oxidation step, the suppression effect of 60 Co deposition was three times higher than that of the Hi

  20. Behavior of sulfur mustard in sand, concrete, and asphalt matrices: Evaporation, degradation, and decontamination.

    Science.gov (United States)

    Jung, Hyunsook; Choi, Seungki

    2017-10-15

    The evaporation, degradation, and decontamination of sulfur mustard on environmental matrices including sand, concrete, and asphalt are described. A specially designed wind tunnel and thermal desorber in combination with gas chromatograph (GC) produced profiles of vapor concentration obtained from samples of the chemical agent deposited as a drop on the surfaces of the matrices. The matrices were exposed to the chemical agent at room temperature, and the degradation reactions were monitored and characterized. A vapor emission test was also performed after a decontamination process. The results showed that on sand, the drop of agent spread laterally while evaporating. On concrete, the drop of the agent was absorbed immediately into the matrix while spreading and evaporating. However, the asphalt surface conserved the agent and slowly released parts of the agent over an extended period of time. The degradation reactions of the agent followed pseudo first order behavior on the matrices. Trace amounts of the residual agent present at the surface were also released as vapor after decontamination, posing a threat to the exposed individual and environment.

  1. Decontamination in the Republic of Belarus

    International Nuclear Information System (INIS)

    Antsipov, G.V.; Matveenko, S.A.; Mirkhaidarov, A.Kh.

    2002-01-01

    To continue the decontamination work in the Republic of Belarus, which was carried out by the military troops, the state specialized enterprises were formed in Gomel and Mogilev in 1991. The organization and regulations were developed inside the country: instructions, rules, radiological and hygienic criteria and norms. The enterprises concentrated on decontamination of the most socially significant facilities: kindergartens, schools, medical institutions and industrial enterprises. During 9 years Gomel State Specialized Enterprise 'Polessje' decontaminated 130 kindergartens, schools and hospitals. The total decontaminated area was 450 000 m 2 . The ventilation systems and equipment at 27 industrial enterprises in Gomel were decontaminated. The practical decontamination methods for areas, buildings, roofs, industrial equipment, ventilation systems were developed and tested. The special rules for handling wastes contaminated with Cs were elaborated. The paper analyzes and sums up the acquired experience which is important for implementation of rehabilitation programs and improvement of decontamination methods. (author)

  2. Development of a Persistent Chemical Agent Simulator System (PCASS)

    Science.gov (United States)

    Mcginness, W. G.

    1983-01-01

    The development of a persistent chemical agent simulation system (PCASS) is described. This PCASS is to be used for the military training of troops to simulate actual chemical warfare. The purpose of this system is to facilitate in the determination of chemical contamination and effectiveness of decontamination for training purposes. The fluorescent tracer employed has no daylight activation, but yet is easily removed with a decontaminate solution or water and surfactants. Also employed is a time delayed color developing system. When an individual is subjected to the PCASS and does not decontaminate adequately, red blotches or red coloration will develop as a function of time and temperature. The intent of this is to simulate the delayed chemical reaction of mustard contaminates.

  3. Decontamination of material in the Marcoule plutonium producing centre (1961); La decontamination du materiel dans le centre de production du plutonium de Marcoule (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Rodier, J; Bouzigues, H; Boutot, P [Commissariat a l' Energie Atomique, Centre de Production de Plutonium, Marcoule (France). Centre d' Etudes Nucleaires

    1961-07-01

    The decontamination of material in an atomic centre is an essential operation in view of the cost and the difficulties of replacement. It also makes it possible to reduce the storage of radio-active materials always an expensive task. Surfaces are contaminated by retention of radioactive products and the mechanism of the bounding forces can be explained in terms of chemical, mechanical, electrostatic and surface tension phenomena. The methods used for decontamination are either physical (section, abrasion, steam, ultrasonics) or chemical (acids, alkalis, detergents, reducing and oxidising agents). At Marcoule, chemical methods of treatment are used. This is effected in tanks, the exact composition of the liquids being regulated from a control panel. Working experience has shown that the fact of operating in humid conditions eliminates all problems of atmospheric contamination; as a result it is possible for the personnel to work without any special protective devices. Almost all the material can be re-utilized and the operations produce only a small volume of liquid waste. The decontamination workshop is operated by a small number of workers. The working costs, including capital repayment and treatment of the waste, do not exceed 15 per cent of the value of the apparatus treated. (authors) [French] La decontamination du materiel dans un centre atomique est une operation indispensable etant donne le cout et les difficultes du remplacement. Elle contribue aussi a diminuer les stockages toujours onereux des materiaux radioactifs. Les surfaces se contaminent par retention de corps radioactifs, l'origine des forces de liaison devant etre recherchee dans les phenomenes chimiques, mecaniques, electro-statiques ou de tensions superficielles. Les methodes de decontamination peuvent etre physiques (aspiration, abrasion, vapeur, ultra-sons) ou chimiques (acides, alcalins, detergents, reducteurs, oxydants). Sur le centre de Marcoule, la methode des traitements chimiques a ete

  4. Vigorous decontamination tests of steel samples

    International Nuclear Information System (INIS)

    Agostinelli, A.; Bregani, F.; Pascali, R.; Ronchetti, C.

    1982-01-01

    Among operative deCommissioning problems, the chemical decontamination of metallic surfaces of LWR, mainly with the use of high vigorous reagents, is being studied in particular. ENEL research activities, partially financed by the European Community Commission, began at the end of 1980, and are being developed by CRTN, Centro di Ricerca Termica e Nucleare, in close connection with ENEL-DPT and CISE. The main aim is the identification, development, and assessment of vigorous decontamination techniques taking into account the amount and disposal cost of liquid radwaste. The test materials come from the primary loop of the BWR-Garigliano plant. Activity levels, mainly due to 60 Co, range from about 0.01 μCi/cm 2 for predecontaminated material to some μCi/cm 2 for virgin material. Moreover, traces of 90 Sr-Y beta pure emitter and alpha emitters are monitored. Research is at first carried out by screening static tests for the optimization of etching static parameters (time, temperature, reagent concentrations). Reagent effectiveness will then be tested in a special experimental loop (DECO), in dynamic conditions simulating in-situ real procedures of decontamination. Hydrofluoric, nitric and hydrochloric acids and mixtures of them have been used for the first tests. Sometimes total oxide removal is possible, and when this takes place, the final contamination levels are in accordance with limits indicated for unrestricted release materials in some countries. 18 references, 13 figures, 5 tables

  5. Personnel decontamination and preventive skin care

    International Nuclear Information System (INIS)

    Henning, Klaus; Gojowczyk, Peter

    2010-01-01

    Skin contamination arises from contact with contaminated aqueous solutions and from transmission of radioactively contaminated dirt particles. As long as the surface of the skin is neither inflamed nor showing any lesions, normally only a limited part of the top layer (epidermis), i.e. the upper layers of the stratum corneum, is contaminated. The intact horny layer has a barrier function protecting against the penetration of chemicals and dirt particles. The horny layer can be damaged by water, solvents, alkaline substances, and acids. In general, it is safe to say that the horny layer acts as a natural barrier to the penetration of liquid and particulate impurities into lower layers of the skin. As long as the horny layer is intact and free from lesions, the risk of incorporation can be considered low. When decontaminating and cleansing the skin, also in daily skin cleansing, care must be taken to prevent the acid protective layer and the horny layer from being compromised. Daily cleansing and cleansing for decontamination must be carried out with a mild, weakly acidic detergent. In addition, prevention should be achieved daily by applying a non-greasy skin lotion to protect the skin. Following a systematic regular regimen in skin cleansing and preventive skin care as well as a specific approach in skin decontamination and cleansing will avoid damage to the skin and remove any contamination incurred. This approach comprises a three-pronged concept, namely skin protection, cleansing and care. (orig.)

  6. Reduced weight decontamination formulation for neutralization of chemical and biological warfare agents

    Science.gov (United States)

    Tucker, Mark D.

    2014-06-03

    A reduced weight DF-200 decontamination formulation that is stable under high temperature storage conditions. The formulation can be pre-packed as an all-dry (i.e., no water) or nearly-dry (i.e., minimal water) three-part kit, with make-up water (the fourth part) being added later in the field at the point of use.

  7. CATALYTIC ENZYME-BASED METHODS FOR WATER TREATMENT AND WATER DISTRIBUTION SYSTEM DECONTAMINATION

    Science.gov (United States)

    Current chemistry-based decontaminants for chemical or biological warfare agents and related toxic materials are caustic and have the potential for causing material and environmental damage. In addition, most are bulk liquids that require significant logistics and storage capabil...

  8. Measurement of Ce(IV) Concentration in Foam Decontaminant containing Fluorosurfactant

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Chong Hun; Yang, H. B.; Yoon, I. H.; Choi, W. K.; Moon, J. K. [KAERI, Daejeon (Korea, Republic of); Lee, J. S. [Gachon University, Seongnam (Korea, Republic of)

    2016-05-15

    To improve the stability of the foam, surfactants and inorganic materials such as nanoparticles can be added. A nanoparticle-based foam decontaminant is composed of a surfactant and nanoparticles for the generation and maintenance of foam, and a chemical decontamination agent made of Ce(IV) dissolved in nitric acid. Ce(IV) will be reduced to Ce(III) through the decontamination process. Oxidizing the cerium (III) can be reused as a decontamination agent, Ce(IV). Oxidation treatment technology by ozone uses its strong oxidizing power. It can be regarded as an environmentally friendly process, because ozone cannot be stored and transported like other industrial gases (because it quickly decays into diatomic oxygen) and must therefore be produced on site, and used ozone can be decomposed immediately. A concentration analysis of Ce(IV) in foam decontaminant containing a surfactant is necessary prior to the derivation of optimal conditions for the regeneration of Ce(III) through ozonation treatment. A UV spectrometric method using the absorbance or potentiometric method with a potential difference in Ce(III)/Ce(IV), or a potentiometric titration method using Fe (II), can be used for a Ce(IV) concentration analysis. A UV spectrometric method has a problem receiving the influence of the surfactant, and a potentiometric method is difficult to use because of the problem of an insignificant change in the potential difference value of the Ce(III)/Ce(IV). Thus, the present study was undertaken to determine whether the potentiometric titration method can be used for an analysis of the Ce(IV) concentration in the nanoparticle-based foam decontaminant containing surfactant. It will be effectively used for the Ce(IV) concentration measurement, in relation to the subsequent research on the derivation of optimal conditions for the regeneration of Ce(III) through ozonation treatment.

  9. Electropolishing as a decontamination process: progress and applications

    International Nuclear Information System (INIS)

    Allen, R.P.; Arrowsmith, H.W.; Charlot, L.A.; Hooper, J.L.

    1978-04-01

    Research studies demonstrated the ability of electropolishing to reduce the radiation levels of steel tools and stainless steel vacuum system components, which were heavily contaminated with plutonium oxide, from 1 million dis/min x 100 cm 2 to background in less than 10 min. Other examples of objects that have been decontaminated within minutes using electropolishing include hot cell manipulator assemblies, analytical instrument components, laboratory transfer containers, offsite shipping containers, fission product storage capsules, laboratory animal cages, and nuclear reactor process tube components. One of the major activities of this research has been the establishment and intensive operation of a 400-gal immersion electropolishing system. Progress has also been made in developing in situ electropolishing techniques that can be used to decontaminate metallic surfaces that cannot readily be transported to or immersed in a conventional electropolishing tank. Sectioning/pretreatment studies are under way to develop and demonstrate optimum disassembly, sectioning, surface preparation, and gross contamination removal procedures. Arc saw, plasma arc torch, and explosive cutting techniques are being evaluated in terms of the thickness and characteristics of the disturbed metal layer. Some of the pretreatment methods under consideration for removal of paint, grease, corrosion layers, and gross contamination include vibratory finishing, ultrasonics, dry and liquid abrasive blasting, and high-pressure spray systems. Other supporting studies are also in progress to provide a sound technical basis for scale-up and widespread application of this new decontamination process. 44 figures

  10. Organophosphate degrading microorganisms and enzymes as biocatalysts in environmental and personal decontamination applications.

    Science.gov (United States)

    Yair, Simo; Ofer, Butnaro; Arik, Eisenkraft; Shai, Shrot; Yossi, Rosman; Tzvika, Dushnitsky; Amir, Krivoy

    2008-01-01

    One of the major challenges in dealing with chemical warfare agent (CWA) dispersal, whether in the battlefield or after a terror act, is decontamination and rehabilitation of any contaminated area. Organophosphates (OPs) are considered to be among the deadliest CWAs to date. Other OPs are used as pesticides in modern agriculture, and are considered environmentally hazardous. Current methods for OP decontamination are either dangerous or insufficiently effective. As a promising solution for this problem, bioremediation--the use of biocomponents for environmental remediation--is a potentially effective, safe, and environment-friendly method. The technology relies on several enzymatic mechanisms, and can be applied in various ways. We will review recent achievements and potential applications, such as biocatalyst-containing foams and an enzymatic sponge, for environmental as well as personal exterior decontamination.

  11. Decontamination technology assessment

    International Nuclear Information System (INIS)

    Allen, R.P.; Konzek, G.J.; Schneider, K.R.; Smith, R.I.

    1988-10-01

    This study identifies and technically assesses foreign decontamination and decommissioning (D and D) technology developments that may represent significant improvements over D and D technology currently available or under development in the United States. Technology need areas for nuclear power reactor decommissioning operations were identified and prioritized using the results of past light water reactor (LWR) decommissioning studies to quantitatively evaluate the potential for reducing cost and decommissioning worker radiation dose for each major decommissioning activity. Based on these identified needs, current foreign D and D technologies of potential interest to the US were identified through personal contacts and the collection and review of an extensive body of D and D literature. These technologies were then assessed qualitatively to evaluate their uniqueness, potential for a significant reduction in D and D costs and/or worker radiation dose, development status, and other factors affecting their value and applicability to US needs. 4 refs

  12. Report on the Decontamination Site Tour in Fukushima Prefecture

    International Nuclear Information System (INIS)

    Knezevic, Z.; Miljanic, S.; Ranogajec-Komor, M.; Milkovic, D; Osvay, M.

    2013-01-01

    In the frame of Japanese-Croatian scientific-technical cooperation, our team visited Minamisoma city in Fukushima prefecture, Japan on Dec 3, 2012. The visit was organized for the foreign participants at the 8th International Workshop on Ionizing Radiation Monitoring held in Oarai, Japan. Minamisoma city is about 25 kilometres north from Fukushima Nuclear Power Plant. The city belonged to the evacuation zone and most of the residents were forced to leave immediately after the accident in 2011. In spring 2012 most of the people were able to return to their homes since dose rates were less than 20 mSv/y, the standard that Japanese government set as a temporary maximum radiation limit. Recently, a project of 'Decontaminating the Living Areas in Minamisoma City' was established. Enormous job has been carried out at the decontamination site (washing the houses, collection of soil, cutting trees, collecting the waste, etc). However, according to some experts, the cost-benefit effect of applied radiation protection principle is questionable. Our team with other participants visited one decontamination site and one temporary waste disposal site. After that a Satellite Meeting entitled 'What can be done for the reconstruction of Fukushima' was organized. In the discussion special attention was given to the public information and communication considering well known fear from radiation and its influence to the future of nuclear power program.(author)

  13. Chemical decontamination of process equipment using recyclable chelating solvent Phase I. Final report, September 1993--June 1995

    International Nuclear Information System (INIS)

    1995-10-01

    The Department of Energy (DOE) is now faced with the task of meeting decontamination and decommissioning obligations at numerous facilities by the year 2019. Due to the tremendous volume of material involved, innovative decontamination technologies are being sought that can reduce the volumes of contaminated waste materials and secondary wastes requiring disposal. With sufficient decontamination, some of the material from DOE facilities could be released as scrap into the commercial sector for recycle, thereby reducing the volume of radioactive waste requiring disposal. Although recycling may initially prove to be more costly than current disposal practices, rapidly increasing disposal costs are expected to make recycling more and more cost effective. Additionally, recycling is now perceived as the ethical choice in a world where the consequences of replacing resources and throwing away reusable materials are impacting the well-being of the environment

  14. Microbiological decontamination of natural honey by irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Migdal, W.; Owczarczyk, H.B.; Kedzia, B.; Holderna-Kedzia, E.; Madajczyk, D

    2000-03-01

    Degree of microbiological decontamination, organoleptic and physico-chemical properties of natural honeys were investigated after radiation treatment. Seven kinds of honeys were irradiated with the beams of 10 MeV electrons from a 10 kW linear accelerator ''Elektronika 10-10'' at the dose 10 kGy. It was shown, that after irradiation, the total count of aerobic and anaerobic bacteria and moulds decrease by 99%. The antibiotic value in investigated honeys increased in turn from 1.67 to 2.67 after irradiation. Such factors and parameters of investigated honeys as their consistency, content of water and saccharose, acidity, the diastase and 5-HMF values were not changed significantly after irradiation. Decontamination by irradiation is a process which allows us to obtain high microbiological purity of honeys. It is especially needed, when honeys are used in surgical treatment of injuries and in nutrition of babies with food deficiency.

  15. 105-DR Large Sodium Fire Facility decontamination, sampling, and analysis plan

    International Nuclear Information System (INIS)

    Knaus, Z.C.

    1995-01-01

    This is the decontamination, sampling, and analysis plan for the closure activities at the 105-DR Large Sodium Fire Facility at Hanford Reservation. This document supports the 105-DR Large Sodium Fire Facility Closure Plan, DOE-RL-90-25. The 105-DR LSFF, which operated from about 1972 to 1986, was a research laboratory that occupied the former ventilation supply room on the southwest side of the 105-DR Reactor facility in the 100-D Area of the Hanford Site. The LSFF was established to investigate fire fighting and safety associated with alkali metal fires in the liquid metal fast breeder reactor facilities. The decontamination, sampling, and analysis plan identifies the decontamination procedures, sampling locations, any special handling requirements, quality control samples, required chemical analysis, and data validation needed to meet the requirements of the 105-DR Large Sodium Fire Facility Closure Plan in compliance with the Resource Conservation and Recovery Act

  16. Metallic surfaces decontamination by using laser light

    International Nuclear Information System (INIS)

    Moggia, Fabrice; Lecardonnel, Xavier

    2013-01-01

    Metal surface cleaning appears to be one of the major priorities for industries especially for nuclear industries. The research and the development of a new technology that is able to meet the actual requirements (i.e. waste volume minimization, liquid effluents and chemicals free process...) seems to be the main commitment. Currently, a wide panel of technologies already exists (e.g. blasting, disk sander, electro-decontamination...) but for some of them, the efficiency is limited (e.g, Dry Ice blasting) and for others, the wastes production (liquid and/or solid) remains an important issue. One answer could be the use of a LASER light process. Since a couple of years, the Clean- Up Business Unit of the AREVA group investigates this decontamination technology. Many tests have been already performed in inactive (i.e. on simulants such as paints, inks, resins, metallic oxides) or active conditions (i.e. pieces covered with a thick metallic oxide layer and metallic pieces covered with grease). The paper will describe the results obtained in term of decontamination efficiency during all our validation process. Metallographic characterizations (i.e. SEM, X-ray scattering) and radiological analysis will be provided. We will also focus our paper on the future deployment of the LASER technology and its commercial use at La Hague reprocessing facility in 2013. (authors)

  17. A comparison of decontamination effects of commercially available detergents in rats pre-exposed to topical sulphur mustard.

    Science.gov (United States)

    Misik, Jan; Jost, Petr; Pavlikova, Ruzena; Vodakova, Eva; Cabal, Jiri; Kuca, Kamil

    2013-06-01

    The genotoxic vesicant sulphur mustard [bis-2-(chloroethyl)sulphide] is a chemical warfare agent which is easily available due to its relatively simple synthesis. Thus, sulphur mustard is a potential agent for mass contamination. In this study, we focused on sulphur mustard toxicity and decontamination in a rat model using commercially available detergent mixtures for dermal decontamination. Male Wistar rats were percutaneously treated with sulphur mustard and subjected to wet decontamination 2 min postexposure. Commercially produced detergents Neodekont™, Argos™, Dermogel™ and FloraFree™ were tested for their decontamination efficacy against an exposed group and their protective ratios determined. The results showed that all tested detergent solutions produced an increase in the median lethal dose [LD(50) = 9.83 (5.87-13.63) mg·kg(-1)] in comparison to controls, which led to increased survival of experimental animals. In general, all tested detergents provided modest decontamination efficacy (PR = 2.0-5.7). The highest protective ratio (5.7) was consistently achieved with Argos™. Accordingly, Argos™ should be considered in further investigation of mass casualty decontamination.

  18. Effects of Vaporized Decontamination Systems on Selected Building Interior Materials: Chlorine Dioxide

    Science.gov (United States)

    2009-02-01

    Chemical Biological Center (ECBC) to take advantage of ECBC’s extensive expertise and specialized research facilities for the decontamination of surfaces...Agency (EPA) established an Interagency Agreement with the U.S. Army Edgewood Chemical Biological Center (ECBC) to take advantage of ECBC’s extensive...Detector (Waters Corporation, Milford, MA). Conductivity suppression was carried out using an ERIS 1000HP Autosuppressor ( Alltech Corporation, Deerfield

  19. Pretreatment with U(IV) solution for improving the decontamination of ruthenium

    International Nuclear Information System (INIS)

    Huang Haoxin; Qi Zhanshun; Zhu Guohui

    1993-01-01

    The ruthenium decontamination factor in Purex process falls quickly in successive TBP cycles. So, it is necessary to change the chemical states of RuNO complexes in order to improve DF Ru in the uranium purification cycle. Hydrazine nitrate is being used to transform RuNO complexes into in-extractable Ru(III)and Ru(IV). However, hydrazine nitrate may be inverted into hydrazoic acid which is dangerous and can bring an unstable factor. Pretreatment using U(IV) solution provides another method to improve the decontamination of ruthenium in Purex process. 0.02 mol/lU(IV) solution can transform RuNO complexes into inextricable species by heating in water bath. The D Ru can be decreased by a factor of 10-20. U(IV) pretreatment does not bring any harmful chemical in process. The acidity has a very large influence on the effect of pretreatment. The higher the acidity is, the worse the effect will be

  20. Uranium enrichment decontamination and decommissioning fund

    International Nuclear Information System (INIS)

    1994-01-01

    One of the most challenging issues facing the Department of Energy's Office of Environmental Management is the cleanup of the three gaseous diffusion plants. In October 1992, Congress passed the Energy Policy Act of 1992 and established the Uranium Enrichment Decontamination and Decommissioning Fund to accomplish this task. This mission is being undertaken in an environmentally and financially responsible way by: devising cost-effective technical solutions; producing realistic life-cycle cost estimates, based on practical assumptions and thorough analysis; generating coherent long-term plans which are based on risk assessments, land use, and input from stakeholders; and, showing near-term progress in the cleanup of the gaseous diffusion facilities at Oak Ridge