WorldWideScience

Sample records for chemical analysis techniques

  1. Chemical analysis by nuclear techniques

    International Nuclear Information System (INIS)

    Sohn, S. C.; Kim, W. H.; Park, Y. J.; Park, Y. J.; Song, B. C.; Jeon, Y. S.; Jee, K. Y.; Pyo, H. Y.

    2002-01-01

    This state art report consists of four parts, production of micro-particles, analysis of boron, alpha tracking method and development of neutron induced prompt gamma ray spectroscopy (NIPS) system. The various methods for the production of micro-paticles such as mechanical method, electrolysis method, chemical method, spray method were described in the first part. The second part contains sample treatment, separation and concentration, analytical method, and application of boron analysis. The third part contains characteristics of alpha track, track dectectors, pretreatment of sample, neutron irradiation, etching conditions for various detectors, observation of track on the detector, etc. The last part contains basic theory, neutron source, collimator, neutron shields, calibration of NIPS, and application of NIPS system

  2. Chemical analysis by nuclear techniques

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, S. C.; Kim, W. H.; Park, Y. J.; Song, B. C.; Jeon, Y. S.; Jee, K. Y.; Pyo, H. Y

    2002-01-01

    This state art report consists of four parts, production of micro-particles, analysis of boron, alpha tracking method and development of neutron induced prompt gamma ray spectroscopy (NIPS) system. The various methods for the production of micro-paticles such as mechanical method, electrolysis method, chemical method, spray method were described in the first part. The second part contains sample treatment, separation and concentration, analytical method, and application of boron analysis. The third part contains characteristics of alpha track, track dectectors, pretreatment of sample, neutron irradiation, etching conditions for various detectors, observation of track on the detector, etc. The last part contains basic theory, neutron source, collimator, neutron shields, calibration of NIPS, and application of NIPS system.

  3. Hybrid chemical and nondestructive-analysis technique

    International Nuclear Information System (INIS)

    Hsue, S.T.; Marsh, S.F.; Marks, T.

    1982-01-01

    A hybrid chemical/NDA technique has been applied at the Los Alamos National Laboratory to the assay of plutonium in ion-exchange effluents. Typical effluent solutions contain low concentrations of plutonium and high concentrations of americium. A simple trioctylphosphine oxide (TOPO) separation can remove 99.9% of the americium. The organic phase that contains the separated plutonium can be accurately assayed by monitoring the uranium L x-ray intensities

  4. New analytical techniques for cuticle chemical analysis

    International Nuclear Information System (INIS)

    Schulten, H.R.

    1994-01-01

    1) The analytical methodology of pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) and direct pyrolysis-mass spectrometry (Py-MS) using soft ionization techniques by high electric fields (FL) are briefly described. Recent advances of Py-GC/MS and Py-FIMS for the analyses of complex organic matter such as plant materials, humic substances, dissolved organic matter in water (DOM) and soil organic matter (SOM) in agricultural and forest soils are given to illustrate the potential and limitations of the applied methods. 2) Novel applications of Py-GC/MS and Py-MS in combination with conventional analytical data in an integrated, chemometric approach to investigate the dynamics of plant lipids are reported. This includes multivariate statistical investigations on maturation, senescence, humus genesis, and environmental damages in spruce ecosystems. 3) The focal point is the author's integrated investigations on emission-induced changes of selected conifer plant constituents. Pattern recognition of Py-MS data of desiccated spruce needles provides a method for distinguishing needles damaged in different ways and determining the cause. Spruce needles were collected from both controls and trees treated with sulphur dioxide (acid rain), nitrogen dioxide, and ozone under controlled conditions. Py-MS and chemometric data evaluation are employed to characterize and classify leaves and their epicuticular waxes. Preliminary mass spectrometric evaluations of isolated cuticles of different plants such as spruce, ivy, holly, and philodendron, as well as ivy cuticles treated in vivo with air pollutants such as surfactants and pesticides are given. (orig.)

  5. Development of chemical analysis techniques: pt. 3

    International Nuclear Information System (INIS)

    Kim, K.J.; Chi, K.Y.; Choi, G.C.

    1981-01-01

    For the purpose of determining trace rare earths a spectrofluorimetric method has been studied. Except Ce and Tb, the fluorescence intensities are not enough to allow satisfactory analysis. Complexing agents such as tungstate and hexafluoroacetylacetone should be employed to increase fluorescence intensities. As a preliminary experiment for the separation of individual rare earth element and uranium, the distribution coefficient, % S here, are obtained on the Dowex 50 W against HCl concentration by a batch method. These % S data are utilized to obtain elution curves. The % S data showed a minimum at around 4 M HCl. To understand this previously known phenomenon the adsorption of Cl - on Dowex 50 W is examined as a function of HCl concentration and found to be decreasing while % S of rare earths increasing. It is interpreted that Cl - and rare earth ions are moved into the resin phase separately and that the charge and the charge densities of these ions are responsible for the different % S curves. Dehydration appears to play an important role in the upturn of the % S curves at higher HCl concentrations

  6. Scanning angle Raman spectroscopy: Investigation of Raman scatter enhancement techniques for chemical analysis

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Matthew W. [Iowa State Univ., Ames, IA (United States)

    2013-01-01

    This thesis outlines advancements in Raman scatter enhancement techniques by applying evanescent fields, standing-waves (waveguides) and surface enhancements to increase the generated mean square electric field, which is directly related to the intensity of Raman scattering. These techniques are accomplished by employing scanning angle Raman spectroscopy and surface enhanced Raman spectroscopy. A 1064 nm multichannel Raman spectrometer is discussed for chemical analysis of lignin. Extending dispersive multichannel Raman spectroscopy to 1064 nm reduces the fluorescence interference that can mask the weaker Raman scattering. Overall, these techniques help address the major obstacles in Raman spectroscopy for chemical analysis, which include the inherently weak Raman cross section and susceptibility to fluorescence interference.

  7. Control charts technique - a tool to data analysis for chemical experiments

    International Nuclear Information System (INIS)

    Yadav, M.B.; Venugopal, V.

    1999-01-01

    A procedure using control charts technique has been developed to analyse data of a chemical experiment which was conducted to assign a value to uranium content in Rb 2 U(SO 4 ) 3 . A value of (34.164 ± 0.031)% has been assigned against (34.167 ± 0.042)% already assigned by analysis of variance (ANOVA) technique. These values do not differ significantly. Merits and demerits of the two techniques have been discussed. (author)

  8. Techniques for SMM/THz Chemical Analysis: Investigations and Exploitation of the Large Molecule Limit

    Science.gov (United States)

    2014-03-03

    SECURITY CLASSIFICATION OF: It has long been recognized that the SMM /THz has a unique combinations of attributes that make it attractive as a basis for...applicability of SMM chemical sensors; the second is to explore infrared – SMM double resonance as a basis for atmospheric remote sensing; and the third...2014 12-Aug-2009 11-Aug-2013 Approved for Public Release; Distribution Unlimited Techniques for SMM /THz Chemical Analysis: Investigations and

  9. Analysis techniques of lattice fringe images for quantified evaluation of pyrocarbon by chemical vapor infiltration.

    Science.gov (United States)

    Li, Miaoling; Zhao, Hongxia; Qi, Lehua; Li, Hejun

    2014-10-01

    Some image analysis techniques are developed for simplifying lattice fringe images of deposited pyrocarbon in carbon/carbon composites by chemical vapor infiltration. They are mainly the object counting method for detecting the optimum threshold, the self-adaptive morphological filtering, the node-separation technique for breaking the aggregate fringes, and some post processing algorithms for reconstructing the fringes. The simplified fringes are the foundation for defining and extracting quantitative nanostructure parameters of pyrocarbon. The frequency filter window of a Fourier transform is defined as the circular band that retains only those fringes with interlayer distance between 0.3 and 0.45 nm. Some judge criteria are set to define topological relation between fringes. For example, the aspect ratio and area of fringes are employed to detect aggregate fringes. Fringe coaxality and distance between endpoints are used to judge the disconnected fringes. The optimum values are determined by using the iterative correction techniques. The best cut-off value for the short fringes is chosen only when there is a reasonable match between the mean fringe length and the value measured by X-ray diffraction. The adopted techniques have been verified to be feasible and to have the potential to convert the complex lattice fringe image to a set of distinct fringe structures.

  10. Use of spectroscopic techniques for the chemical analysis of biomorphic silicon carbide ceramics

    International Nuclear Information System (INIS)

    Pavon, J.M. Cano; Alonso, E. Vereda; Cordero, M.T. Siles; Torres, A. Garcia de; Lopez-Cepero, J.M.

    2005-01-01

    Biomorphic silicon carbide ceramics are a new class of materials prepared by several complex processing steps including pre-processing (shaping, drying, high-temperature pyrolysis in an inert atmosphere) and reaction with liquid silicon to obtain silicon-carbide. The results of industrial process of synthesis (measured by the SiC content) must be evaluated by means of fast analytical methods. In the present work, diverse samples of biomorphic ceramics derived from wood are studied for to evaluate the capability of the different analytical techniques (XPS, LIBS, FT-IR and also atomic spectroscopy applied to previously dissolved samples) for the analysis of these materials. XPS and LIBS gives information about the major components, whereas XPS and FT-IR can be used to evaluate the content of SiC. On the other hand, .the use of atomic techniques (as ICP-MS and ETA-AAS) is more adequate for the analysis of metal ions, specially at trace level. The properties of ceramics depend decisively of the content of chemical elements. Major components found were C, Si, Al, S, B and Na in all cases. Previous dissolution of the samples was optimised by acid attack in an oven under microwave irradiation

  11. Comparative analysis of the aroma chemicals of Melissa officinalis using hydrodistillation and HS-SPME techniques

    Directory of Open Access Journals (Sweden)

    Shakeel-u- Rehman

    2017-05-01

    Full Text Available Headspace solid-phase micro extraction (HS-SPME coupled with gas chromatography–mass spectrometry (GC–MS has been used for the chemical analysis of Melissa officinalis (leaves cultivated in Institute Germplasm. The HS-SPME analysis led to the identification of 22 components constituting 99.1% of the total volatile constituents present in the leaves whereas its hydrodistillate led to the identification of 24 volatile constituents constituting 98.1% of the volatile material. The chemical composition of the SPME and hydrodistilled extract of M. officinalis leaves comprised mainly of oxygenated monoterpenes (78.5% and 57.8% respectively and sesquiterpene hydrocarbons (14.9% and 29.7% respectively. The major components identified in the HS-SPME extract were citronellal (31.1%, citronellol (18.3%, β-caryophyllene (12.0%, (E-citral (11.9%, (Z-citral (9.6%, geraniol (3.6%, (Z-β-ocimene (3.1% and 1-octen-3-ol (2.0% whereas hydrodistilled essential oil was rich in (Z-citral (19.6%, β-caryophyllene (13.2%, (E-citral (11.2%, citronellal (10.2%, germacrene-d (8.3%, δ-3-carene (5.0%, 6-methyl-5-hepten-2-one (3.7% and citronellyl acetate (3.7%. The comparative analysis of volatile constituents of M. officinalis leaf extract using HS-SPME and hydrodistillation techniques shows both qualitative as well as quantitative differences. The current study is the first report involving rapid analysis of volatile components of M. officinalis by HS-SPME.

  12. The composition-explicit distillation curve technique: Relating chemical analysis and physical properties of complex fluids.

    Science.gov (United States)

    Bruno, Thomas J; Ott, Lisa S; Lovestead, Tara M; Huber, Marcia L

    2010-04-16

    The analysis of complex fluids such as crude oils, fuels, vegetable oils and mixed waste streams poses significant challenges arising primarily from the multiplicity of components, the different properties of the components (polarity, polarizability, etc.) and matrix properties. We have recently introduced an analytical strategy that simplifies many of these analyses, and provides the added potential of linking compositional information with physical property information. This aspect can be used to facilitate equation of state development for the complex fluids. In addition to chemical characterization, the approach provides the ability to calculate thermodynamic properties for such complex heterogeneous streams. The technique is based on the advanced distillation curve (ADC) metrology, which separates a complex fluid by distillation into fractions that are sampled, and for which thermodynamically consistent temperatures are measured at atmospheric pressure. The collected sample fractions can be analyzed by any method that is appropriate. The analytical methods we have applied include gas chromatography (with flame ionization, mass spectrometric and sulfur chemiluminescence detection), thin layer chromatography, FTIR, corrosivity analysis, neutron activation analysis and cold neutron prompt gamma activation analysis. By far, the most widely used analytical technique we have used with the ADC is gas chromatography. This has enabled us to study finished fuels (gasoline, diesel fuels, aviation fuels, rocket propellants), crude oils (including a crude oil made from swine manure) and waste oils streams (used automotive and transformer oils). In this special issue of the Journal of Chromatography, specifically dedicated to extraction technologies, we describe the essential features of the advanced distillation curve metrology as an analytical strategy for complex fluids. Published by Elsevier B.V.

  13. Precession technique and electron diffractometry as new tools for crystal structure analysis and chemical bonding determination

    International Nuclear Information System (INIS)

    Avilov, A.; Kuligin, K.; Nicolopoulos, S.; Nickolskiy, M.; Boulahya, K.; Portillo, J.; Lepeshov, G.; Sobolev, B.; Collette, J.P.; Martin, N.; Robins, A.C.; Fischione, P.

    2007-01-01

    We have developed a new fast electron diffractometer working with high dynamic range and linearity for crystal structure determinations. Electron diffraction (ED) patterns can be scanned serially in front of a Faraday cage detector; the total measurement time for several hundred ED reflections can be tens of seconds having high statistical accuracy for all measured intensities (1-2%). This new tool can be installed to any type of TEM without any column modification and is linked to a specially developed electron beam precession 'Spinning Star' system. Precession of the electron beam (Vincent-Midgley technique) reduces dynamical effects allowing also use of accurate intensities for crystal structure analysis. We describe the technical characteristics of this new tool together with the first experimental results. Accurate measurement of electron diffraction intensities by electron diffractometer opens new possibilities not only for revealing unknown structures, but also for electrostatic potential determination and chemical bonding investigation. As an example, we present detailed atomic bonding information of CaF 2 as revealed for the first time by precise electron diffractometry

  14. Quantitative chemical analysis of lead in canned chillis by spectrophotometric and nuclear techniques

    International Nuclear Information System (INIS)

    Sanchez Paz, L.A.

    1991-01-01

    The objectives of this work are the quantification of lead contents in two types of canned chilli of three trademarks, determining its inside of maximum permissible level (2 ppm), comparing moreover two trademarks that have flask and canned presentation for to determine the filling effect in the final content of lead, moreover make a comparative study of the techniques using on base to exactitude, linearity and sensibility. The techniques used were atomic absorption spectrophotometry, plasma emission spectrometry and x-ray fluorescence. The preliminary treatment of the samples was by calcination, continued of the ashes dissolution in acid medium, for later gauge a determinate volume for analyze by atomic absorption and plasma emission. For the analysis by x-ray fluorescence, after solubilyzing ashes, its precipitate the lead with PCDA (Pyrrolidine carbodithioic ammonium acid) then its filtered, filter paper is dried and counted directly. The standards preparation is made following the same procedure as in samples using lead titrisol solution. For each technique the recovery percent is determined by the addition of enough know amount. For each technique calibration curves are plotted been determined that the three are lineal in the established range of work. The recovery percent in three cases is superior to ninety five percent. By means of a variance analysis it was determined that lead contain in samples do not exceed two ppm., and the lead content in canned chillis is superior to contained in glass containers (1.7, 0.4 ppm respectively). X-ray fluorescence analysis is different to the attained results by the other two techniques due to its sensibility is less. The most advisable techniques for this kind of analysis are atomic absorption spectrophotometry and plasma emission. (Author)

  15. Nuclear and radiochemical techniques in chemical analysis. Progress report, 1 June 1974--31 May 1975

    International Nuclear Information System (INIS)

    Finston, H.L.; Williams, E.T.

    1975-01-01

    Progress on the project to determine the neutron-absorption cross section of 22 Na is described. Upper limits for the thermal-neutron cross sections of 88 Y and 139 Ce have been set at 100 barns. The experiment to search for a change in the ratio of electron capture to positron emission due to difference in chemical environment is underway. The mechanical aspects of the system for analysis by proton-induced x-ray emission are described. Recent results on solvent extraction of mercury by pure solvents and propylene carbonate are described. Recent measurements in a study of an acid-base hypothesis are described. (U.S.)

  16. Nuclear and radiochemical techniques in chemical analysis. Progress report, June 1, 1975--July 31, 1976

    International Nuclear Information System (INIS)

    Finston, H.L.; Williams, E.T.

    1976-01-01

    There has been significant progress on the project to measure the neutron-capture cross sections of reactor produced radionuclides, in particular, centering on the problems with nuclides such as 22 Na which may have a resonance for thermal-neutron capture. The thermal capture cross section of less than 40 b has been verified for 54 Mn, and cadmium ratios have been determined for 184 Re in the V-11 and V-14 positions in the HFBR. Lutetium has been used as a neutron temperature monitor for the Brookhaven reactors. Preliminary results on the project to determine the effect of chemical state on the branching ratio in 58 Co are reported. Procedures for aerosol collection and analysis by proton-induced x-ray emission (PIXE) are reported. A program to analyze aerosols for polycyclic aromatic hydrocarbons has been initiated. Progress is reported on the experimental verification of the proposed acid-base hypothesis

  17. Nuclear and radiochemical techniques in chemical analysis. Progress report, August 1, 1978-July 31, 1979

    International Nuclear Information System (INIS)

    Finston, H.L.; Williams, E.T.

    1979-07-01

    Studies of homogeneous liquid-liquid extraction have been extended to include (1) a detailed determination of the phase diagram of the system propylene carbonate-water, (2) the extraction of a large variety of both monodentate and bidentate iron complexes, (3) the solvent extraction characteristics of analogues of propylene carbonate, (4) the behavior under pressure of the propylene carbonate water system, and (5) the extraction behavior of alkaline earth - TTA chelates. One consequence of these studies was the observation that the addition of ethanol to propylene carbonate-water or to isobutylene carbonate-water yields a single homogeneous phase. Subsequent evaporation of the ethanol restores the two immiscible phases. Past neutron activation analysis has been attempted for the heavy elements Pb, Bi, Tl at the Brookhaven HFBR (in- or near-core position) and at the Brookhaven CLIF facility. The latter appears more promising and we have initiated a collaborative program to use the CLIF facility. A milking system which can provide ca. 16 μCi of carrier-free 212 Pb was developed for use in an isotope dilution technique for lead. Collaboration with laboratories already determining trace lead by flameless Atomic Absorption or by concentration by electrodeposition into a hanging drop followed by Anodic stripping will be proposed. The Proton X-Ray Emission system has undergone marked improvement with the acquisition of a new high resolution Si(Li) detector and a new multi-channel analyzer system. Various techniques have been explored to dissolve and prepare samples for PIXE analysis and also for verification by Atomic Absorption analysis

  18. Nuclear and radiochemical techniques in chemical analysis. Progress report, August 1, 1978-July 31, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Finston, H. L.; Williams, E. T.

    1979-07-01

    Studies of homogeneous liquid-liquid extraction have been extended to include (1) a detailed determination of the phase diagram of the system propylene carbonate-water, (2) the extraction of a large variety of both monodentate and bidentate iron complexes, (3) the solvent extraction characteristics of analogues of propylene carbonate, (4) the behavior under pressure of the propylene carbonate water system, and (5) the extraction behavior of alkaline earth - TTA chelates. One consequence of these studies was the observation that the addition of ethanol to propylene carbonate-water or to isobutylene carbonate-water yields a single homogeneous phase. Subsequent evaporation of the ethanol restores the two immiscible phases. Past neutron activation analysis has been attempted for the heavy elements Pb, Bi, Tl at the Brookhaven HFBR (in- or near-core position) and at the Brookhaven CLIF facility. The latter appears more promising and we have initiated a collaborative program to use the CLIF facility. A milking system which can provide ca. 16 ..mu..Ci of carrier-free /sup 212/Pb was developed for use in an isotope dilution technique for lead. Collaboration with laboratories already determining trace lead by flameless Atomic Absorption or by concentration by electrodeposition into a hanging drop followed by Anodic stripping will be proposed. The Proton X-Ray Emission system has undergone marked improvement with the acquisition of a new high resolution Si(Li) detector and a new multi-channel analyzer system. Various techniques have been explored to dissolve and prepare samples for PIXE analysis and also for verification by Atomic Absorption analysis.

  19. A comparison of partial order technique with three methods of multi-criteria analysis for ranking of chemical substances.

    Science.gov (United States)

    Lerche, Dorte; Brüggemann, Rainer; Sørensen, Peter; Carlsen, Lars; Nielsen, Ole John

    2002-01-01

    An alternative to the often cumbersome and time-consuming risk assessments of chemical substances could be more reliable and advanced priority setting methods. An elaboration of the simple scoring methods is provided by Hasse Diagram Technique (HDT) and/or Multi-Criteria Analysis (MCA). The present study provides an in depth evaluation of HDT relative to three MCA techniques. The new and main methodological step in the comparison is the use of probability concepts based on mathematical tools such as linear extensions of partially ordered sets and Monte Carlo simulations. A data set consisting of 12 High Production Volume Chemicals (HPVCs) is used for illustration. It is a paradigm in this investigation to claim that the need of external input (often subjective weightings of criteria) should be minimized and that the transparency should be maximized in any multicriteria prioritisation. The study illustrates that the Hasse diagram technique (HDT) needs least external input, is most transparent and is least subjective. However, HDT has some weaknesses if there are criteria which exclude each other. Then weighting is needed. Multi-Criteria Analysis (i.e. Utility Function approach, PROMETHEE and concordance analysis) can deal with such mutual exclusions because their formalisms to quantify preferences allow participation e.g. weighting of criteria. Consequently MCA include more subjectivity and loose transparency. The recommendation which arises from this study is that the first step in decision making is to run HDT and as the second step possibly is to run one of the MCA algorithms.

  20. Comparison of results analysis of chemical composition of alloys inside the U-Zr-Nb by XRF and AAS techniques

    International Nuclear Information System (INIS)

    Masrukan; Tri Yulianto; Anwar Muchsin

    2011-01-01

    U-Zr-Nb alloy chemical composition analysis using X Ray Fluorescence (XRF) and Atomic Absorption Spectroscopy (AAS) techniques have been conducted, where U-Zr- Nb alloy was chosen as candidates for new high-density fuel for future research reactors . Composition analysis is necessary because the composition of elements in the fuel will determine the characteristics of fuel during the fabrication process and in the reactor. The use of two kinds of analysis techniques were designed to obtain accurate analysis results. The experiment was conducted to determine the major element composition and impurities in the alloy U-Zr-Nb. First U-Zr-Nb varying alloy composition Nb were respectively 1%, 4%, 7% (U10% Zr1% Nb, U10% Zr4% Nb and U10% 7% Nb) as results of the melting process of measuring the diameter of 120 mm crushed on the surface bottom. Once on the bottom surface is smooth, then analyzed using XRF techniques. To analyze the elements using AAS techniques, alloy U-Zr-Nb cut into 10 mm x 5 mm then dissolved using HF and nitric acid. Solution that occurred were analyzed using AAS technique. From the analysis using the XRF technique is obtained the alloy U-10% Zr-1% Nb, U-10% Zr-4% Nb and Zr-10% U-7% Nb) had a content of each element as follows: U (87.8858%), Zr (2.6097%) and Nb (0.2206%), U (87.8556%), Zr (2.6302%), and Nb (0.6573%); U (84.6334%), Zr (2.5773%), and Nb (1.0940) weight. Results of analysis using AAS techniques on samples obtained third consecutive Zr content of 9.25%, 8.90% and 9.80% while the content of Nb was not detected. Meanwhile, the results of elemental analysis of impurities in all three samples showed that almost all the elements are still qualify as fuel except Zn element. Element Zn at the three samples of each alloys U-10% Zr-1% Nb, U-10% Zr-4% Nb and U-10% Zr-7%Nb is 1.3266%, 3.2756% and 1.0927% weight. It could be concluded that the results of analysis of elemental content and impurities in the alloy U-Nb-Zr using both XRF and AAS visible

  1. Modern sample preparation techniques for gas chromatography-mass spectrometry analysis of environmental markers of chemical warfare agents use

    NARCIS (Netherlands)

    Terzic, O.; de Voogt, P.; Banoub, J.

    2014-01-01

    The chapter introduces problematics of on-site chemical analysis in the investigations of past chemical warfare agents (CWA) events. An overview of primary environmental degradation pathways of CWA leading to formation of chemical markers of their use is given. Conventional and modern sample

  2. Nuclear and radiochemical techniques in chemical analysis. Progress report, August 1, 1977--July 31, 1978

    International Nuclear Information System (INIS)

    Finston, H.L.; Williams, E.T.

    1978-07-01

    The study of neutron-absorption cross sections of reactor-produced radionuclides has been completed, and results are reported for 22 Na, 126 I, 139 Ce, 88 Y, 184 Re, 182 Ta, 54 Mn, and 94 Zr. The results for 22 Na indicate the existence of a resonance in the thermal region which could explain the discrepancies in the published values for the thermal cross section. The results of air-sampling experiments are described as is the proton-induced x-ray emission system developed at Brooklyn College. Work on sample preparation and applications of the PIXE technique are given. Progress on a nuclear method to determine fluorine-containing gaseous compounds is reported. Work on solvent extraction with propylene carbonate and experiments involving an acid-base hypothesis are described

  3. Chemical Separation Technique of Strontium-90 in the Soil Water as theStandard Methods for Environmental Radioactivity Analysis

    International Nuclear Information System (INIS)

    Ngasifudin-Hamdani; Suratman; Djoko-Sardjono, Ign; Winduanto-Wahyu SP

    2000-01-01

    Research about separation technique of strontium-90 from its materialmatrix using chemical precipitation method has been done. That technique wasapplied on the detection of radionuclide strontium-90 containing in the soilwater of near nuclear reactor facility P3TM BATAN in three location. The twoimportant parameters used in this technique were growth time of Y-90 andstirring time. The result shown that activity of strontium-90 in the pos-01was between 1.801x10 -19 - 9.616x10 -17 μCi/cm 3 , pos-02 was8.448x10 -19 - 1.003x X 10 -16 μCi/cm 3 and pos-03 was 6.719x10 -19 - 11.644x10 -16 μCi/cm 3 . From those data shown that activity of Sr-90in the soil water of near nuclear reactor facility P3TM BATAN was still belowthe limit value of maximum concentration permitted i.e. 4.0x10 -7 -3.5x10 -6 μCi/cm 3 . The statistic test using analysis of varian twofactorial with random block design shown that the activity of Sr-90 in thesoil water was influenced by the interaction which take place between growthlong time of Y-90 and stirring long time. (author)

  4. Traditional versus commercial food processing techniques - A comparative study based on chemical analysis of selected foods consumed in rural Zimbabwe.

    Directory of Open Access Journals (Sweden)

    Abraham I. C. Mwadiwa

    2012-01-01

    Full Text Available With the advent of industrialisation, food processors are constantly looking for ways to cut costs, increase production and maximise profits at the expense of quality. Commercial food processors have since shifted their focus from endogenous ways of processing food to more profitable commercial food processing techniques. The aim of this study was to investigate the holistic impact of commercial food processing techniques on nutrition by comparing commercially (industrially processed food products and endogenously processed food products through chemical analysis of selected foods. Eight food samples which included commercially processed peanut butter, mealie-meal, dried vegetables (mufushwa and rice and endogenously processed peanut butter, mealie-meal, dried vegetables (mufushwa and rice were randomly sampled from rural communities in the south-eastern and central provinces of Zimbabwe. They were analysed for ash, zinc, iron, copper, magnesium, protein, fat, carbohydrates, energy, crude fibre, vitamin C and moisture contents. The results of chemical analysis indicate that endogenously processed mealie-meal, dried vegetables and rice contained higher ash values of 2.00g/100g, 17.83g/100g, and 3.28g/100g respectively than commercially processed mealie-meal, dried vegetables and rice, which had ash values of 1.56g/100g, 15.25g/100g and 1.46g/100g respectively. The results also show that endogenously processed foods have correspondingly higher iron, zinc and magnesium contents and, on the whole, a higher protein content. The results also indicate that commercially processed foods have higher fat and energy contents. The result led to the conclusion that the foods are likely to pose a higher risk of causing adverse conditions to health, such as obesity and cardiovascular diseases to susceptible individuals. Based on these findings, it can, therefore, be concluded that endogenously processed foods have a better nutrient value and health implications

  5. Use of radioactive double labelling technique in the chemical analysis of the mediators of cellular immunity

    International Nuclear Information System (INIS)

    Sorg, C.

    1978-01-01

    Radioactive double labelling was adapted for the analysis of mediators of cellular immunity. Two identical lymphocyte cultures were simultaneously labelled with [ 3 H]- or [ 14 C] leucine. Each of the cultures was stimulated with antigen or mitogen. The combined supernatants were then subjected to various fractionation procedures. By determining the isotope ratio in each fraction it is possible to identify those products of activated lymphocytes that have been produced either de novo or in increased amounts. The method proved sensitive enough to detect lymphocyte activation products in supernatants of activated lymphocyte cultures from guinea pig, mouse, and man

  6. Chemical Security Analysis Center

    Data.gov (United States)

    Federal Laboratory Consortium — In 2006, by Presidential Directive, DHS established the Chemical Security Analysis Center (CSAC) to identify and assess chemical threats and vulnerabilities in the...

  7. Microprocessors in automatic chemical analysis

    International Nuclear Information System (INIS)

    Goujon de Beauvivier, M.; Perez, J.-J.

    1979-01-01

    Application of microprocessors to programming and computing of solutions chemical analysis by a sequential technique is examined. Safety, performances reliability are compared to other methods. An example is given on uranium titration by spectrophotometry [fr

  8. Determination of Methylmercury Traces in Biological Matrix: Chemical Extraction and Nuclear Quantification with the Neutron Activation Analysis Technique

    International Nuclear Information System (INIS)

    Soldati, A.L.

    2002-01-01

    Mercury is present in the environment as a result of the human and natural activities.The total amount of Hg present in the biosphere has been incremented three times since the industrial era, and now it is affecting in a global sense all the ecosystem.One of the main entrance of Hg in the human diet is the consumption of fish and other marine creatures.Most of the ingested Hg is mono methylmercury (MeHg), which is one of the most toxic forms in which this element could be found because it crosses membranes.Since the toxicity levels are low, the determination of concentrations of total Hg and Me Hg require very careful sampling, sample conditioning and analytical procedures to prevent either losses or contamination, or the degradation of the Hg species.In this work, we implemented a chemical Me Hg extraction procedure, using a ionic exchange resin, with three different types of fish tissue: muscle, liver and hepato pancreas.After Me Hg extraction, the determination and quantification was made by Instrumental Neutron Activation Analysis, by measuring the 197 Au, y el 203 Tl deexcitation s, created through the radioactive decay of the isotopes 197 Hg y 203 Hg.The influence of several parameters on the overall extraction process, such as velocity of passage through the ionic exchange column and the acid concentration used in the extraction was evaluated.Regarding the INAA determinations, a choice was made for the irradiation, decay and counting times, neutron and gamma doses, and the counting geometry The detection limit found for this technique (dry weight) is 140 pg MeHg/g. The Hg contents of the muscle samples were measured with the 279 keV emission of the product of the 202 Hg(n,g) 203 Hg reaction, with a recovery of (100 ± 13)%. Liver and Hepato pancreas samples were measured with the 77 keV gamma emission of the 197 Hg, checking this result with the 67 y 69 keV X emissions from the same isotope.The liver samples needed an extra vacuum filtering process during

  9. Chemical substructure analysis in toxicology

    Energy Technology Data Exchange (ETDEWEB)

    Beauchamp, R.O. Jr. [Center for Information on Toxicology and Environment, Raleigh, NC (United States)

    1990-12-31

    A preliminary examination of chemical-substructure analysis (CSA) demonstrates the effective use of the Chemical Abstracts compound connectivity file in conjunction with the bibliographic file for relating chemical structures to biological activity. The importance of considering the role of metabolic intermediates under a variety of conditions is illustrated, suggesting structures that should be examined that may exhibit potential activity. This CSA technique, which utilizes existing large files accessible with online personal computers, is recommended for use as another tool in examining chemicals in drugs. 2 refs., 4 figs.

  10. Analysis of High Quality Agar wood Oil Chemical Compounds By Means Of SPME/ GC-MS and Z-Score Technique

    International Nuclear Information System (INIS)

    Nurlaila Ismail; Mohd Ali Nor Azah; Mailina Jamil; Saiful Nizam Tajuddin; Mohd Nasir Taib

    2013-01-01

    Currently, the grading of the agar wood oil to the high and low quality is done using manually such as human trained grader. It was performed based on the agar wood oil physical properties such as human experience and perception and the oil colour, odor and long lasting aroma. Several researchers found that chemical profiles of the oil should be utilized to overcome the problem facing by manual techniques for example human nose cannot tolerate with the many oils at the same time, so that accurate result can be obtained in grading the agar wood oil. The analysis involved of SPME/ GC-MS and Z-score techniques have been proposed in this study to analyze the chemical compounds especially from the high quality samples of agar wood oil (Aquilariamalaccensis) from Malaysia. Two SPME fibers were used such as divinylbenzene-carbogen-polydimethylsiloxane (DVB-CAR-PDMS) and polydimethylsiloxane (PDMS) in extracting the oils compound under three different sampling temperature conditions such as 40, 60 and 80 degree Celsius. The chemical compounds extracted by SPME/ GC-MS were analyzed. The chemical compounds as identified by Z-score as significant compounds were discussed before the conclusion is made. It was found that 10-epi-γ-eudesmol, aromadendrene, β-agar ofuran, α-agar ofuran and γ-eudesmol were highlighted as significant for high quality agar wood oil and can be used as a marker compounds in classifying the agar wood oil. (author)

  11. Chemical imaging techniques for the analysis of complex mixtures: New application to the characterization of ritual matters on African wooden statuettes

    International Nuclear Information System (INIS)

    Mazel, Vincent; Richardin, Pascale; Touboul, David; Brunelle, Alain; Walter, Philippe; Laprevote, Olivier

    2006-01-01

    Chemical imaging techniques, based on the combination of microscopy and spectroscopy, are well suited to study both the composition and the spatial organization of heterogeneous complex mixtures of organic and mineral matter. Time-of-flight secondary ion mass spectrometry (ToF-SIMS), followed by scanning electron microscopy with energy dispersive X-ray analysis (SEM-EDX) and Fourier transform infrared microscopy (FTIR microscopy) have been applied to non-destructive analysis of micro-samplings of ritual matters deposited on the surface of African wooden statuettes. With a very careful preparation, using ultramicrotomy on embedded samples, it was possible to perform successively all the measurements on a single fragment. Comparison and superposition of the different chemical images, obtained on a sample from a significant actual artefact, have allowed us to identify minerals (clays, quartz and calcium carbonate), proteins, starch, urate salts and lipids and to map their spatial distribution

  12. Nuclear techniques in coal and chemical industries

    International Nuclear Information System (INIS)

    Elbern, A.W.; Leal, C.A.

    1980-01-01

    The use of nuclear techniques for the determination of important parameters in industrial installations is exemplified; advantages of these techniques over other methods conventionally used are pointed out. The use of radiotracers in the study of physical and chemical phenomena occurring in the chemical industry is discussed. It is also shown that, using certain radioisotopes, it is possible to construct devices which enable, for example, the determination of the ash content in coal samples. These devices are economical and easy to be installed for the on-line control during coal transportation. (C.L.B.) [pt

  13. Chemical analysis report 2014

    International Nuclear Information System (INIS)

    Elbouzidi, Saliha; Elyahyaoui, Adil; Ghassan, Acil; Marah, Hamid

    2014-01-01

    This report highlights the results of chemical analyzes related to Major elements, traces and heavy metals carried out at the CNESTEN DASTE in Rabat (Morocco), on behalf of Senegal. These analyzes cover 120 samples. The report presents the analytical techniques used (parameters and methods), a legend and the results tables.

  14. Chemical analysis report 2015

    International Nuclear Information System (INIS)

    2015-01-01

    This report highlights the results of chemical analyzes of fluorides, bromides, lithium and boron carried out at the CNESTEN DASTE in Rabat (Morocco), on behalf of Senegal. These analyzes cover 120 samples. The report presents the analytical techniques used (parameters and methods), a legend and the results tables.

  15. Chemical process hazards analysis

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    The Office of Worker Health and Safety (EH-5) under the Assistant Secretary for the Environment, Safety and Health of the US Department (DOE) has published two handbooks for use by DOE contractors managing facilities and processes covered by the Occupational Safety and Health Administration (OSHA) Rule for Process Safety Management of Highly Hazardous Chemicals (29 CFR 1910.119), herein referred to as the PSM Rule. The PSM Rule contains an integrated set of chemical process safety management elements designed to prevent chemical releases that can lead to catastrophic fires, explosions, or toxic exposures. The purpose of the two handbooks, ``Process Safety Management for Highly Hazardous Chemicals`` and ``Chemical Process Hazards Analysis,`` is to facilitate implementation of the provisions of the PSM Rule within the DOE. The purpose of this handbook ``Chemical Process Hazards Analysis,`` is to facilitate, within the DOE, the performance of chemical process hazards analyses (PrHAs) as required under the PSM Rule. It provides basic information for the performance of PrHAs, and should not be considered a complete resource on PrHA methods. Likewise, to determine if a facility is covered by the PSM rule, the reader should refer to the handbook, ``Process Safety Management for Highly Hazardous Chemicals`` (DOE- HDBK-1101-96). Promulgation of the PSM Rule has heightened the awareness of chemical safety management issues within the DOE. This handbook is intended for use by DOE facilities and processes covered by the PSM rule to facilitate contractor implementation of the PrHA element of the PSM Rule. However, contractors whose facilities and processes not covered by the PSM Rule may also use this handbook as a basis for conducting process hazards analyses as part of their good management practices. This handbook explains the minimum requirements for PrHAs outlined in the PSM Rule. Nowhere have requirements been added beyond what is specifically required by the rule.

  16. Chemical analysis of geological samples

    International Nuclear Information System (INIS)

    Malhotra, R.K.

    1997-01-01

    Most of the analytical methodology used in geochemical exploration has been based on molecular absorption, atomic absorption, and ICP-AES, ICPMAS etc. Detection limit and precision are factors in the choice of methodology in search of metallic ores and are related to the accuracy of data. A brief outline of the various chemical analysis techniques explaining essentially the basics of measurement principles and instrumentation is discussed

  17. Chemical and canine analysis as complimentary techniques for the identification of active odors of the invasive fungus, Raffaelea lauricola.

    Science.gov (United States)

    Simon, Alison G; Mills, DeEtta K; Furton, Kenneth G

    2017-06-01

    Raffaelea lauricola, a fungus causing a vascular wilt (laurel wilt) in Lauraceae trees, was introduced into the United States in the early 2000s. It has devastated forests in the Southeast and has now moved into the commercial avocado groves in southern Florida. Trained detection canines are currently one of the few successful methods for early detection of pre-symptomatic diseased trees. In order to achieve the universal and frequent training required to have successful detection canines, it is desirable to create accessible, safe, and long-lasting training aids. However, identification of odorants and compounds is limited by several factors, including both the availability of chemicals and the need to present chemicals individually and in combination to detection canines. A method for the separation and identification of volatile organic compounds (VOCs) from environmental substances for the creation of such a canine training aid is presented here. Headspace solid phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) was used to identify the odors present in avocado trees infected with the R. lauricola phytopathogen. Twenty-eight compounds were detected using this method, with nine present in greater than 80% of samples. The majority of these compounds were not commercially available as standard reference materials, and a canine trial was designed to identify the active odors without the need of pure chemical compounds. To facilitate the creation of a canine training aid, the VOCs above R. lauricola were separated by venting a 0.53mm ID solgel-wax gas chromatography column to the atmosphere. Ten minute fractions of the odor profile were collected on cotton gauze in glass vials and presented to the detection canines in a series of field trials. The canines alerted to the VOCs from the vials that correspond to a portion of the chromatogram containing the most volatile species from R. lauricola. This innovative fractionation and collection

  18. The potential of organic (electrospray- and atmospheric pressure chemical ionisation) mass spectrometric techniques coupled to liquid-phase separation for speciation analysis.

    Science.gov (United States)

    Rosenberg, Erwin

    2003-06-06

    The use of mass spectrometry based on atmospheric pressure ionisation techniques (atmospheric pressure chemical ionisation, APCI, and electrospray ionisation, ESI) for speciation analysis is reviewed with emphasis on the literature published in and after 1999. This report accounts for the increasing interest that atmospheric pressure ionisation techniques, and in particular ESI, have found in the past years for qualitative and quantitative speciation analysis. In contrast to element-selective detectors, organic mass spectrometric techniques provide information on the intact metal species which can be used for the identification of unknown species (particularly with MS-MS detection) or the confirmation of the actual presence of species in a given sample. Due to the complexity of real samples, it is inevitable in all but the simplest cases to couple atmospheric pressure MS detection to a separation technique. Separation in the liquid phase (capillary electrophoresis or liquid chromatography in reversed phase, ion chromatographic or size-exclusion mode) is particularly suitable since the available techniques cover a very wide range of analyte polarities and molecular mass. Moreover, derivatisation can normally be avoided in liquid-phase separation. Particularly in complex environmental or biological samples, separation in one dimension is not sufficient for obtaining adequate resolution for all relevant species. In this case, multi-dimensional separation, based on orthogonal separation techniques, has proven successful. ESI-MS is also often used in parallel with inductively coupled plasma MS detection. This review is structured in two parts. In the first, the fundamentals of atmospheric pressure ionisation techniques are briefly reviewed. The second part of the review discusses recent applications including redox species, use of ESI-MS for structural elucidation of metal complexes, characterisation and quantification of small organometallic species with relevance to

  19. Analysis of the chemical elements behavior in leaves infected with fumagina employing X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Blonski, Maria Selia

    2002-02-01

    Fumagina is produced by the Capnodium fungi, a mushroom from Dothideales order, that lives associated with the yellow aphid (Monelliopsis pecanis), excreting a heavy load of a sugared substance that provides the sooty fungus development, covering, in some cases the totality, of leaves, fruits and branches surfaces. One of the big problems caused by this disease is the physic photosynthesis stuckness, reducing in 98% the active photosynthesis radiation and in 70% the net photosynthesis. This photosynthesis reduction affects the plants carbohydrate reservoirs, resulting in reduced and bad qualified crops. It was employed the Energy Dispersion X-Ray Fluorescence Technique (EDXRF) to study the fumagina disease. The measurements were realized with infected and healthy leaves of citric plants (orange and lemon trees), collected at the Farm School of the State University of Londrina, and also leaves of icsora plant from Piracicaba-SP. Through this technique it was observed a metabolic disorder related to Fe and Ca elements. By comparing the EDXRF spectra of the healthy plant leaves with the infected ones, it was verified that the concentration of Ca is higher than the concentration Fe in leaves of healthy plants, while for the leaves of plants infected with fumagina, it was observed a higher concentration of Fe. Employing EDXRF and the emission/transmission method for the matrix effect correction, samples of the citric plants were also analysed in pellet. The elements K, Ca, Ti, Mn , Fe, Cu and Zn were quantified. It was verified a higher Fe concentration in fumagina samples compared to the samples without fumagina. For all the elements of interest the minimum level of detection found was at the order of μg g -1 . (author)

  20. Analysis and analytical techniques

    Energy Technology Data Exchange (ETDEWEB)

    Batuecas Rodriguez, T [Department of Chemistry and Isotopes, Junta de Energia Nuclear, Madrid (Spain)

    1967-01-01

    The technology associated with the use of organic coolants in nuclear reactors depends to a large extent on the determination and control of their physical and chemical properties, and particularly on the viability, speed, sensitivity, precision and accuracy (depending on the intended usage) of the methods employed in detection and analytical determination. This has led to the study and development of numerous techniques, some specially designed for the extreme conditions involved in working with the types of product in question and others adapted from existing techniques. In the specific case of polyphenyl and hydropolyphenyl mixtures, which have been the principal subjects of study to date and offer greatest promise, the analytical problems are broadly as follows: Composition of initial product or virgin coolant composition of macro components and amounts of organic and inorganic impurities; Coolant during and after operation. Determination of gases and organic compounds produced by pyrolysis and radiolysis (degradation and polymerization products); Control of systems for purifying and regenerating the coolant after use. Dissolved pressurization gases; Detection of intermediate products during decomposition; these are generally very unstable (free radicals); Degree of fouling and film formation. Tests to determine potential formation of films; Corrosion of structural elements and canning materials; Health and safety. Toxicity, inflammability and impurities that can be activated. Although some of the above problems are closely interrelated and entail similar techniques, they vary as to degree of difficulty. Another question is the difficulty of distinguishing clearly between techniques for determining physical and physico-chemical properties, on one hand, and analytical techniques on the other. Any classification is therefore somewhat arbitrary (for example, in the case of dosimetry and techniques for determining mean molecular weights or electrical conductivity

  1. Analysis of Steady, Two-Dimensional Chemically Reacting Nonequilibrium Flow by an Unsteady, Asymptotically Consistent Technique. Volume I. Theoretical Development.

    Science.gov (United States)

    1982-09-01

    wall, and exit points are know,, collectively as boundary points. In the following discussion, thi numerical treatment used for each type of mesh point...and fiozen solutions and that it matches the ODK solution 6 [Reference (10)] quite well. Also note that in this case, there is only a small departure...shows the results of the H-F system analysis. The mass-averaged temperature profile falls between the equilibrium and frozen solutions and matches the ODK

  2. INTERNAL ENVIRONMENT ANALYSIS TECHNIQUES

    Directory of Open Access Journals (Sweden)

    Caescu Stefan Claudiu

    2011-12-01

    Full Text Available Theme The situation analysis, as a separate component of the strategic planning, involves collecting and analysing relevant types of information on the components of the marketing environment and their evolution on the one hand and also on the organization’s resources and capabilities on the other. Objectives of the Research The main purpose of the study of the analysis techniques of the internal environment is to provide insight on those aspects that are of strategic importance to the organization. Literature Review The marketing environment consists of two distinct components, the internal environment that is made from specific variables within the organization and the external environment that is made from variables external to the organization. Although analysing the external environment is essential for corporate success, it is not enough unless it is backed by a detailed analysis of the internal environment of the organization. The internal environment includes all elements that are endogenous to the organization, which are influenced to a great extent and totally controlled by it. The study of the internal environment must answer all resource related questions, solve all resource management issues and represents the first step in drawing up the marketing strategy. Research Methodology The present paper accomplished a documentary study of the main techniques used for the analysis of the internal environment. Results The special literature emphasizes that the differences in performance from one organization to another is primarily dependant not on the differences between the fields of activity, but especially on the differences between the resources and capabilities and the ways these are capitalized on. The main methods of analysing the internal environment addressed in this paper are: the analysis of the organizational resources, the performance analysis, the value chain analysis and the functional analysis. Implications Basically such

  3. Superconducting lead particles produced by chemical techniques

    Science.gov (United States)

    Fariss, T. L.; Nixon, W. E.; Bucelot, T. J.; Deaver, B. S., Jr.; Mitchell, J. W.

    1982-09-01

    The superconductivity of extremely small lead particles has been studied as a function of size, surface condition, and connectivity using chemical techniques to produce particles of well-controlled size and shape suspended in insulating media. Approximately monodisperse suspensions of equiaxed, rod, and lath-shaped particles of lead halides and other lead compounds suspended in gelatin, polyacrylamide, polyvinylpyrrolidone, polyvinyl alcohol, methyl cellulose, and hydroxyethyl cellulose have been produced. These particles have been reduced to pseudomorphs of lead in the liquid phase or the suspensions have been coated on substrates and dried before reduction. Reducing solutions containing aminoiminomethanesulfinic acid are effective with particles of lead halides, lead phosphate, lead sulfate, and lead tartrate. Suspensions of smaller discrete lead particles have also been produced by direct reduction of solutions of soluble lead salts containing suitable polymers, chelating, and stabilizing agents. Dispersions with mean particle dimensions between 3 nm and 5 μm, and a narrow size-frequency distribution, have been produced. The superconductivity of the particles has been characterized by measurements of the magnetization as a function of temperature and magnetic field. The larger particles have a transition temperature of 7.2 K, the same as bulk lead; however, for particles of characteristic dimensions less than 20 nm, the transition temperature is lower by ˜0.1 K.

  4. Superconducting lead particles produced by chemical techniques

    International Nuclear Information System (INIS)

    Fariss, T.L.; Nixon, W.E.; Bucelot, T.J.; Deaver, B.S. Jr.; Mitchell, J.W.

    1982-01-01

    The superconductivity of extremely small lead particles has been studied as a function of size, surface condition, and connectivity using chemical techniques to produce particles of well-controlled size and shape suspended in insulating media. Approximately monodisperse suspensions of equiaxed, rod, and lath-shaped particles of lead halides and other lead compounds suspended in gelatin, polyacrylamide, polyvinylpyrrolidone, polyvinyl alcohol, methyl cellulose, and hydroxyethyl cellulose have been produced. These particles have been reduced to pseudomorphs of lead in the liquid phase or the suspensions have been coated on substrates and dried before reduction. Reducing solutions containing aminoiminomethanesulfinic acid are effective with particles of lead halides, lead phosphate, lead sulfate, and lead tartrate. Suspensions of smaller discrete lead particles have also been produced by direct reduction of solutions of soluble lead salts containing suitable polymers, chelating, and stabilizing agents. Dispersions with mean particle dimensions between 3 nm and 5 μm, and a narrow size-frequency distribution, have been produced. The superconductivity of the particles has been characterized by measurements of the magnetization as a function of temperature and magnetic field. The larger particles have a transition temperature of 7.2 K, the same as bulk lead; however, for particles of characteristic dimensions less than 20 nm, the transition temperature is lower by approx.0.1 K

  5. Decision Analysis Technique

    Directory of Open Access Journals (Sweden)

    Hammad Dabo Baba

    2014-01-01

    Full Text Available One of the most significant step in building structure maintenance decision is the physical inspection of the facility to be maintained. The physical inspection involved cursory assessment of the structure and ratings of the identified defects based on expert evaluation. The objective of this paper is to describe present a novel approach to prioritizing the criticality of physical defects in a residential building system using multi criteria decision analysis approach. A residential building constructed in 1985 was considered in this study. Four criteria which includes; Physical Condition of the building system (PC, Effect on Asset (EA, effect on Occupants (EO and Maintenance Cost (MC are considered in the inspection. The building was divided in to nine systems regarded as alternatives. Expert's choice software was used in comparing the importance of the criteria against the main objective, whereas structured Proforma was used in quantifying the defects observed on all building systems against each criteria. The defects severity score of each building system was identified and later multiplied by the weight of the criteria and final hierarchy was derived. The final ranking indicates that, electrical system was considered the most critical system with a risk value of 0.134 while ceiling system scored the lowest risk value of 0.066. The technique is often used in prioritizing mechanical equipment for maintenance planning. However, result of this study indicates that the technique could be used in prioritizing building systems for maintenance planning

  6. Construction technique for a chemical plant (I)

    International Nuclear Information System (INIS)

    1978-08-01

    This book mentions the order of plant construction, building plant and related regulations, basic engineering design data, provide of equipment, plan and management on building plant, quality control, the budget and contract for building plant, public works for building chemical plant like road construction, basic plan and building for a chemical plant, introduction and principle on foundation improvement method, including pile foundation and design for footing, construction and installation for a chemical plant and a rotary machine for a chemical plant.

  7. Construction technique for a chemical plant (III)

    International Nuclear Information System (INIS)

    1978-08-01

    This book mentions design of instrumentation and construction for a chemical plant, which deals with the change of instrumentation, construction, choice of material test, construction of thermal insulation work for a chemical plant, about classification and main materials, the problems on construction, painting plan and construction for a chemical plant such as paint and painting, safety and hygiene, cleaning of a chemical plant on the time for washing and decision of the way of washing, start up test for a chemical plant such as introduction of the check, construction and repair.

  8. Meeting on risk and monitoring analysis techniques for food safety - RLA/5/060/ARCAL Project (ARCAL CXXVIII): sampling plans and introduction to chemical risk assessment in food innocuousness

    International Nuclear Information System (INIS)

    2013-03-01

    Some of the Latinoamerican countries such us Bolivia, Colombia, Uruguay and Venezuela participant in the meeting gave an exposition about the risk analysis and monitoring techniques in food safety in their countyries. With the aim to study components of risk analysis, food innocuousness, evaluation and chemical dangers, toxicity, exposure, change of paradigms in the global food system, data sources, study in animals and in vitro, sensitivity analysis, risk assessment in health it carried out the meeting

  9. Construction technique for a chemical plant (II)

    International Nuclear Information System (INIS)

    1978-08-01

    This book deals with design and construction for a chemical plant which includes design and building of steel structure for a chemical plant with types, basic regulation, plan, shop fabrication for steel structure and field construction. It explains design and construction of making building for a chemical construction with measurement, types of building and basic rule of the building, design of the building, constructing plumbing for a chemical plant with plan, management of material, checking for construction, construction of electrical installation on plan, know-how to construction and maintenance.

  10. From the coupling between ion beam analysis techniques and physico-chemical characterization methods to the study of irradiation effects on materials behaviour

    International Nuclear Information System (INIS)

    Millard-Pinard, N.

    2003-01-01

    The general purpose of my research work is to follow and to interpret the surface evolution of materials, which have received several treatments. During my PhD and my post-doc work, my field of research was tribology. Since I arrived in the 'Aval du Cycle Electronucleaire' group of the Institut de Physique Nucleaire de Lyon, my research activities are in line with the CNRS program 'PACE ' (Programme sur l'Aval du Cycle Electronucleaire) within the ACTINET network. They are coordinated by the PARIS (Physico-chimie des actinides et autres radioelements en solution et aux interfaces) and NOMADE (NOuveaux MAteriaux pour les DEchets) GDR with ANDRA (Agence Nationale pour la gestion des Dechets RAdioactifs), EDF and IRSN (Institut de Radioprotection et de Surete Nucleaire) as partner organisations. My work focused on the study of fission products and actinides migration in barrier materials, which may be capable of assuring the long term safety of deep geological repositories. Until now, it was necessary to use the coupling of ion beam analysis techniques and physico-chemical characterization techniques. During the last few months, I have became interested in understanding radiolytic effects. This new orientation has led us to use ion beams as an irradiating tool. These irradiation experiments are pursued in three major projects. The study of cobalt sulfide inhibition effects of radiolysis gas production during the irradiation of model organic molecules. This is a collaboration with the IRSN, the Institut de Recherche sur la Catalyse and the Ecole Nationale Superieure des Mines de Saint-Etienne. A PhD, co-directed by M. Pijolat from ENSMSE and myself, concerning this study will start in October 2003. Water radiolysis effects on iron corrosion are also studied in the particular case of vitrified nuclear waste containers, which will be stored in deep geological repositories. One ANDRA financed PhD, co-directed by Nathalie Moncoffre and myself, is dedicated to this study

  11. Uncertainty analysis techniques

    International Nuclear Information System (INIS)

    Marivoet, J.; Saltelli, A.; Cadelli, N.

    1987-01-01

    The origin of the uncertainty affecting Performance Assessments, as well as their propagation to dose and risk results is discussed. The analysis is focused essentially on the uncertainties introduced by the input parameters, the values of which may range over some orders of magnitude and may be given as probability distribution function. The paper briefly reviews the existing sampling techniques used for Monte Carlo simulations and the methods for characterizing the output curves, determining their convergence and confidence limits. Annual doses, expectation values of the doses and risks are computed for a particular case of a possible repository in clay, in order to illustrate the significance of such output characteristics as the mean, the logarithmic mean and the median as well as their ratios. The report concludes that provisionally, due to its better robustness, such estimation as the 90th percentile may be substituted to the arithmetic mean for comparison of the estimated doses with acceptance criteria. In any case, the results obtained through Uncertainty Analyses must be interpreted with caution as long as input data distribution functions are not derived from experiments reasonably reproducing the situation in a well characterized repository and site

  12. CHEMICAL PROFILES OF HONEYS ORIGINATING FROM DIFFERENT FLORAL SOURCES AND GEOGRAPHIC LOCATIONS EXAMINED BY A COMBINATION OF THREE EXTRACTION AND ANALYSIS TECHNIQUES

    Directory of Open Access Journals (Sweden)

    D. M. Meloncelli

    2015-05-01

    Full Text Available The chemical profiles of Tasmanian Leatherwood and Manuka honeys from Tasmania and New Zealand have been compared by a combination of GC-MS analysis of volatiles and semi-volatiles, RP-HPLC-DAD analysis of phenolics and flavonoids and HPLC-DAD analysis of derivatised dihydroxyacetone, hydroxymethylfurfural and methylglyoxal. This study found that Tasmanian and New Zealand Manuka honeys have high concentrations of methylglyoxal. However, syringic acid was only detected in Manuka honeys grown in New Zealand. The Tasmanian honeys can be distinguished by the higher concentration of 3-phenyllactic acid in Manuka compared to Leatherwood floral sources.

  13. CHEMICAL PROFILES OF HONEYS ORIGINATING FROM DIFFERENT FLORAL SOURCES AND GEOGRAPHIC LOCATIONS EXAMINED BY A COMBINATION OF THREE EXTRACTION AND ANALYSIS TECHNIQUES

    Directory of Open Access Journals (Sweden)

    D. M. Meloncelli,

    2015-02-01

    Full Text Available The chemical profiles of Tasmanian Leatherwood and Manuka honeys from Tasmania and New Zealand have been compared by a combination of GC-MS analysis of volatiles and semi-volatiles, RP-HPLC-DAD analysis of phenolics and flavonoids and HPLC-DAD analysis of derivatised dihydroxyacetone, hydroxymethylfurfural and methylglyoxal. This study found that Tasmanian and New Zealand Manuka honeys have high concentrations of methylglyoxal. However, syringic acid was only detected in Manuka honeys grown in New Zealand. The Tasmanian honeys can be distinguished by the higher concentration of 3-phenyllactic acid in Manuka compared to Leatherwood floral sources.

  14. Molecular activation analysis for chemical speciation studies

    International Nuclear Information System (INIS)

    Chai-Chifang

    1998-01-01

    The term of Molecular Activation Analysis (MAA) refers to an activation analysis method that is able to provide information about the chemical species of elements in system of interests, though its definition has remained to be assigned. Its development is strongly stimulated by the urgent need to know the chemical species of elements, because the total concentrations are often without any meaning when assessing health or environmental risks of trace elements.In practice, the MAA is a combination of conventional instrumental or radiochemical activation analysis and physical, chemical or biochemical separation techniques. The MAA is able to play a particular role in speciation studies. However, the critical point in the MAA is that it is not permitted to change the primitive chemical species of elements in systems, or the change has to be under control; in the meantime it is not allowed to form the 'new artifact' originally not present in systems. Some practical examples of MAA for chemical species research performed recently in our laboratory will be presented as follows: Chemical species of platinum group elements in sediment; Chemical species of iodine in marine algae; Chemical species of mercury in human tissues; Chemical species of selenium in corn; Chemical species of rare earth elements in natural plant, etc. The merits and limitations of MAA will be described as well. (author)

  15. Teaching Chemical Equilibrium with the Jigsaw Technique

    Science.gov (United States)

    Doymus, Kemal

    2008-01-01

    This study investigates the effect of cooperative learning (jigsaw) versus individual learning methods on students' understanding of chemical equilibrium in a first-year general chemistry course. This study was carried out in two different classes in the department of primary science education during the 2005-2006 academic year. One of the classes…

  16. Quality assurance techniques for activation analysis

    International Nuclear Information System (INIS)

    Becker, D.A.

    1984-01-01

    The principles and techniques of quality assurance are applied to the measurement method of activation analysis. Quality assurance is defined to include quality control and quality assessment. Plans for quality assurance include consideration of: personnel; facilities; analytical design; sampling and sample preparation; the measurement process; standards; and documentation. Activation analysis concerns include: irradiation; chemical separation; counting/detection; data collection, and analysis; and calibration. Types of standards discussed include calibration materials and quality assessment materials

  17. A comparative quantitative analysis of the IDEAL (iterative decomposition of water and fat with echo asymmetry and least-squares estimation) and the CHESS (chemical shift selection suppression) techniques in 3.0 T L-spine MRI

    Science.gov (United States)

    Kim, Eng-Chan; Cho, Jae-Hwan; Kim, Min-Hye; Kim, Ki-Hong; Choi, Cheon-Woong; Seok, Jong-min; Na, Kil-Ju; Han, Man-Seok

    2013-03-01

    This study was conducted on 20 patients who had undergone pedicle screw fixation between March and December 2010 to quantitatively compare a conventional fat suppression technique, CHESS (chemical shift selection suppression), and a new technique, IDEAL (iterative decomposition of water and fat with echo asymmetry and least squares estimation). The general efficacy and usefulness of the IDEAL technique was also evaluated. Fat-suppressed transverse-relaxation-weighed images and longitudinal-relaxation-weighted images were obtained before and after contrast injection by using these two techniques with a 1.5T MR (magnetic resonance) scanner. The obtained images were analyzed for image distortion, susceptibility artifacts and homogenous fat removal in the target region. The results showed that the image distortion due to the susceptibility artifacts caused by implanted metal was lower in the images obtained using the IDEAL technique compared to those obtained using the CHESS technique. The results of a qualitative analysis also showed that compared to the CHESS technique, fewer susceptibility artifacts and more homogenous fat removal were found in the images obtained using the IDEAL technique in a comparative image evaluation of the axial plane images before and after contrast injection. In summary, compared to the CHESS technique, the IDEAL technique showed a lower occurrence of susceptibility artifacts caused by metal and lower image distortion. In addition, more homogenous fat removal was shown in the IDEAL technique.

  18. Laser chemical analysis: the recent developments

    International Nuclear Information System (INIS)

    Mauchien, P.

    1997-01-01

    This paper gives a general overview and describes the principles of the main laser-based techniques for physical and chemical analysis, and of their recent developments. Analytical techniques using laser radiations were actually developed at the end of the 1970's. The recent evolutions concern the 3 principal techniques of laser spectroscopy currently used: Raman, fluorescence (atomic and molecular) and ablation (ICP laser ablation-plasma coupling, optical emission spectroscopy on laser-induced plasma). The description of these different techniques is illustrated with some examples of applications. (J.S.)

  19. Chemical Analysis Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Uses state-of-the-art instrumentation for qualitative and quantitative analysis of organic and inorganic compounds, and biomolecules from gas, liquid, and...

  20. Teaching Chemical Equilibrium with the Jigsaw Technique

    Science.gov (United States)

    Doymus, Kemal

    2008-03-01

    This study investigates the effect of cooperative learning (jigsaw) versus individual learning methods on students’ understanding of chemical equilibrium in a first-year general chemistry course. This study was carried out in two different classes in the department of primary science education during the 2005-2006 academic year. One of the classes was randomly assigned as the non-jigsaw group (control) and other as the jigsaw group (cooperative). Students participating in the jigsaw group were divided into four “home groups” since the topic chemical equilibrium is divided into four subtopics (Modules A, B, C and D). Each of these home groups contained four students. The groups were as follows: (1) Home Group A (HGA), representin g the equilibrium state and quantitative aspects of equilibrium (Module A), (2) Home Group B (HGB), representing the equilibrium constant and relationships involving equilibrium constants (Module B), (3) Home Group C (HGC), representing Altering Equilibrium Conditions: Le Chatelier’s principle (Module C), and (4) Home Group D (HGD), representing calculations with equilibrium constants (Module D). The home groups then broke apart, like pieces of a jigsaw puzzle, and the students moved into jigsaw groups consisting of members from the other home groups who were assigned the same portion of the material. The jigsaw groups were then in charge of teaching their specific subtopic to the rest of the students in their learning group. The main data collection tool was a Chemical Equilibrium Achievement Test (CEAT), which was applied to both the jigsaw and non-jigsaw groups The results indicated that the jigsaw group was more successful than the non-jigsaw group (individual learning method).

  1. Evaluation of boiler chemical cleaning techniques

    International Nuclear Information System (INIS)

    1993-04-01

    The EPRI/SGOG process, which has been selected by Ontario Hydro for use at the Bruce A station, is described. This process consists of alternating iron removal and copper removal steps, the two metals which comprise the bulk of the deposit in the Bruce A SGs. The iron removal solvent consists of ethylenediameinetetraacetic acid (EDTA), hydrazine, ammonium hydroxide and a proprietary corrosion inhibitor CCI-801. The copper removal solvent consists of EDTA, ethylene diamine and hydrogen peroxide. Ontario Hydro proposes to clean a bank of four SGs in parallel employing a total of six copper removal steps and four iron removal steps. Cleaning all eight SGs in a single Bruce A unit will generate 2,200 m 3 of liquid waste which will be treated by a wet air oxidation process. The iron and copper sludges will be buried in a landfill site while the liquid waste will be further treated by the Bruce sewage treatment plant. Some ammonia vapour will be generated through the wet air oxidation process and will be vented through a stack on top of the high bay of the spent solvent treatment plant. With the exception of the proprietary corrosion inhibitor, all chemicals that will be employed in the cleaning and waste treatment operations are standard industrial chemicals which are well characterized. No extraordinary hazards are anticipated with their use as long as adequate safety precautions are taken

  2. Analysis of chemical bond states and electrical properties of stacked AlON/HfO{sub 2} gate oxides formed by using a layer-by-layer technique

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Wonjoon; Lee, Jonghyun; Yang, Jungyup; Kim, Chaeok; Hong, Jinpyo; Nahm, Tschanguh; Byun, Byungsub; Kim, Moseok [Hanyang University, Seoul (Korea, Republic of)

    2006-06-15

    Stacked AlON/HfO{sub 2} thin films for gate oxides in metal-oxide-semiconductor devices are successfully prepared on Si substrates by utilizing a layer-by-layer technique integrated with an off-axis RF remote plasma sputtering process at room temperature. This off-axis structure is designed to improve the uniformity and the quality of gate oxide films. Also, a layer-by-layer technique is used to control the interface layer between the gate oxide and the Si substrate. The electrical properties of our stacked films are characterized by using capacitance versus voltage and leakage current versus voltage measurements. The stacked AlON/HfO{sub 2} gate oxide exhibits a low leakage current of about 10{sup -6} A/cm{sup 2} and a high dielectric constant value of 14.26 by effectively suppressing the interface layer between gate oxide and Si substrate. In addition, the chemical bond states and the optimum thickness of each AlON and HfO{sub 2} thin film are analyzed using X-ray photoemission spectroscopy and transmission electron microscopy measurement.

  3. Multivariate analysis techniques

    Energy Technology Data Exchange (ETDEWEB)

    Bendavid, Josh [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Fisher, Wade C. [Michigan State Univ., East Lansing, MI (United States); Junk, Thomas R. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2016-01-01

    The end products of experimental data analysis are designed to be simple and easy to understand: hypothesis tests and measurements of parameters. But, the experimental data themselves are voluminous and complex. Furthermore, in modern collider experiments, many petabytes of data must be processed in search of rare new processes which occur together with much more copious background processes that are of less interest to the task at hand. The systematic uncertainties on the background may be larger than the expected signal in many cases. The statistical power of an analysis and its sensitivity to systematic uncertainty can therefore usually both be improved by separating signal events from background events with higher efficiency and purity.

  4. Trace Chemical Analysis Methodology

    Science.gov (United States)

    1980-04-01

    147 65 Modified DR/2 spectrophotometer face ........... ... 150 66 Colorimetric oil analysis field test kit ......... .. 152 67 Pictorial step...Assisted Pattern Recognitio Perhaps the most promising application of pattern recogntiontechniques for this research effort is the elucidation ".f the...large compartment on the spectrophotomer face . The screwdriver is used to adjust the zero adjust and light ad- just knobs, and the stainless steel

  5. Analysis of chemical dissolution of the barrier layer of porous oxide on aluminum thin films using a re-anodizing technique

    Energy Technology Data Exchange (ETDEWEB)

    Vrublevsky, I. [Department of Microelectronics, Belarusian State University of Informatics and Radioelectronics, 6 Brovka street, Minsk 220013 (Belarus)]. E-mail: nil-4-2@bsuir.edu.by; Parkoun, V. [Department of Microelectronics, Belarusian State University of Informatics and Radioelectronics, 6 Brovka street, Minsk 220013 (Belarus); Sokol, V. [Department of Microelectronics, Belarusian State University of Informatics and Radioelectronics, 6 Brovka street, Minsk 220013 (Belarus); Schreckenbach, J. [Institut fuer Chemie, Technische Universitaet Chemnitz, Chemnitz D-09107 (Germany)

    2005-09-30

    Chemical dissolution of the barrier layer of porous oxide formed on thin aluminum films (99.9% purity) in the 4% oxalic acid after immersion in 2 mol dm{sup -3} sulphuric acid at 50 deg. C has been studied. The barrier layer thickness before and after dissolution was calculated using a re-anodizing technique. It has been shown that above 57 V the change in the growth mechanism of porous alumina films takes place. As a result, the change in the amount of regions in the barrier oxide with different dissolution rates is observed. The barrier oxide contains two layers at 50 V: the outer layer with the highest dissolution rate and the inner layer with a low dissolution rate. Above 60 V the barrier oxide contains three layers: the outer layer with a high dissolution rate, the middle layer with the highest dissolution rate and the inner layer with a low dissolution rate. We suggest that the formation of the outer layer of barrier oxide with a high dissolution rate is linked with the injection of protons or H{sub 3}O{sup +} ions from the electrolyte into the oxide film at the anodizing voltages above 57 V.

  6. Soil analysis. Modern instrumental technique

    International Nuclear Information System (INIS)

    Smith, K.A.

    1993-01-01

    This book covers traditional methods of analysis and specialist monographs on individual instrumental techniques, which are usually not written with soil or plant analysis specifically in mind. The principles of the techniques are combined with discussions of sample preparation and matrix problems, and critical reviews of applications in soil science and related disciplines. Individual chapters are processed separately for inclusion in the appropriate data bases

  7. Surface analysis the principal techniques

    CERN Document Server

    Vickerman, John C

    2009-01-01

    This completely updated and revised second edition of Surface Analysis: The Principal Techniques, deals with the characterisation and understanding of the outer layers of substrates, how they react, look and function which are all of interest to surface scientists. Within this comprehensive text, experts in each analysis area introduce the theory and practice of the principal techniques that have shown themselves to be effective in both basic research and in applied surface analysis. Examples of analysis are provided to facilitate the understanding of this topic and to show readers how they c

  8. Chemical vapor deposition: A technique for applying protective coatings

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, T.C. Sr.; Bowman, M.G.

    1979-01-01

    Chemical vapor deposition is discussed as a technique for applying coatings for materials protection in energy systems. The fundamentals of the process are emphasized in order to establish a basis for understanding the relative advantages and limitations of the technique. Several examples of the successful application of CVD coating are described. 31 refs., and 18 figs.

  9. The development of chemical speciation analysis

    International Nuclear Information System (INIS)

    Martin, R.; Santana, J.L.; Lima, L.; De La Rosa, D.; Melchor, K.

    2003-01-01

    The knowledge of many metals species on the environmental, its bioaccumulation, quantification and its effect in human body has been studied by a wide researchers groups in the last two decades. The development of speciation analysis has an vertiginous advance close to the developing of novel analytical techniques. Separation and quantification at low level is a problem that's has been afford by a coupling of high resolution chromatographic techniques like HPLC and HRGC with a specific method of detection (ICP-MS or CV-AAS). This methodological approach make possible the success in chemical speciation nowadays

  10. Molecular structure, electronic properties, NLO, NBO analysis and spectroscopic characterization of Gabapentin with experimental (FT-IR and FT-Raman) techniques and quantum chemical calculations

    Science.gov (United States)

    Sinha, Leena; Karabacak, Mehmet; Narayan, V.; Cinar, Mehmet; Prasad, Onkar

    2013-05-01

    Gabapentin (GP), structurally related to the neurotransmitter GABA (gamma-aminobutyric acid), mimics the activity of GABA and is also widely used in neurology for the treatment of peripheral neuropathic pain. It exists in zwitterionic form in solid state. The present communication deals with the quantum chemical calculations of energies, geometrical structure and vibrational wavenumbers of GP using density functional (DFT/B3LYP) method with 6-311++G(d,p) basis set. In view of the fact that amino acids exist as zwitterions as well as in the neutral form depending on the environment (solvent, pH, etc.), molecular properties of both the zwitterionic and neutral form of GP have been analyzed. The fundamental vibrational wavenumbers as well as their intensities were calculated and compared with experimental FT-IR and FT-Raman spectra. The fundamental assignments were done on the basis of the total energy distribution (TED) of the vibrational modes, calculated with scaled quantum mechanical (SQM) method. The electric dipole moment, polarizability and the first hyperpolarizability values of the GP have been calculated at the same level of theory and basis set. The nonlinear optical (NLO) behavior of zwitterionic and neutral form has been compared. Stability of the molecule arising from hyper-conjugative interactions and charge delocalization has been analyzed using natural bond orbital analysis. Ultraviolet-visible (UV-Vis) spectrum of the title molecule has also been calculated using TD-DFT method. The thermodynamic properties of both the zwitterionic and neutral form of GP at different temperatures have been calculated.

  11. Development of techniques for tagging precursor and essential chemicals

    Energy Technology Data Exchange (ETDEWEB)

    Swansiger, W.A.; Shepodd, T.J. [Sandia National Labs., Livermore, CA (United States); Phillips, M.L.F. [Sandia National Labs., Albuquerque, NM (United States)

    1994-01-01

    The ability to identify the manufacturers and distributors of chemicals seized in raids of illicit drug labs would be of great value in controlling the diversion of these chemicals. We developed a tagging scheme based on the addition of sub-ppM concentrations of various combinations of rare-earth elements to the target chemicals and evaluated a number of techniques for detecting the tags. We developed soluble tags for tagging liquids and selected Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) as the preferred detection technique. We developed insoluble tags for tagging solids and developed methods to analyze them and mix them into solid precursors. We have successfully demonstrated the tagging of several solvents and two of the precursor chemicals used in one of the most popular clandestine methamphetamine syntheses (ephedrine reacting with hydriodic acid/red phosphorus). The tagging scheme is capable of yielding tens of thousands of signatures (using holmium as an internal standard and up to 9 rare-earths at up to 3 concentrations yields 3{sup 9} {minus} 1 = 19,682 signatures) and is applicable to most of the chemicals on the precursor and essential chemicals list. In the concentrations employed, the tags are safe enough to be added to pharmaceuticals and cheap enough to tag tanker loads of chemicals.

  12. Characteristics of nanosized zirconia prepared by plasma and chemical technique

    International Nuclear Information System (INIS)

    Kuznetsova, L.; Grabis, J.; Heidemane, G.

    2003-01-01

    The studied preparation method of zirconia using the plasma technique, azeotropic distillation and glycine routes ensure obtaining of nano sized powders with close average particle size but different crystallite size and phase composition. The sinterability of nano sized zirconia particles prepared by plasma technique or wet-chemical methods is similar and depends on the green density of pressed powders, improvement of with can be achieved by using of granulated precursors. (authors)

  13. Bulk analysis using nuclear techniques

    International Nuclear Information System (INIS)

    Borsaru, M.; Holmes, R.J.; Mathew, P.J.

    1983-01-01

    Bulk analysis techniques developed for the mining industry are reviewed. Using penetrating neutron and #betta#-radiations, measurements are obtained directly from a large volume of sample (3-30 kg) #betta#-techniques were used to determine the grade of iron ore and to detect shale on conveyor belts. Thermal neutron irradiation was developed for the simultaneous determination of iron and aluminium in iron ore on a conveyor belt. Thermal-neutron activation analysis includes the determination of alumina in bauxite, and manganese and alumina in manganese ore. Fast neutron activation analysis is used to determine silicon in iron ores, and alumina and silica in bauxite. Fast and thermal neutron activation has been used to determine the soil in shredded sugar cane. (U.K.)

  14. Chemical analysis of refractories by plasma spectrometry

    International Nuclear Information System (INIS)

    Coutinho, C.A.

    1990-01-01

    X-ray spectrometry has been, since the last two or three decades, the traditional procedure for the chemical analysis of refractories, due to its high degree of accuracy and speed to produce analytical results. An interesting alternative to X-ray fluorescence is provided by the Inductively Coupled Plasma Spectrometry technique, for those laboratories where wet chemistry facilities are already available or process control is not required at high speed, or investiment costs have to be low. This paper presents results obtained by plasma spectroscopy for the analysis of silico - aluminous refractories, showing calibration curves, precion and detection limits. Considerations and comparisons with X-ray fluorescence are also made. (author) [pt

  15. Rapid chemical analysis of allanite

    International Nuclear Information System (INIS)

    Nishiyama, Goro; Hayashi, Hiroshi

    1981-01-01

    Rapid chemical analysis of allanite was studied by atomic absorption spectrophotometry. Powdered sample was fused with mixture of sodium carbonate anhydrous and borax (4 : 1 weight) in platinum crucible and sample solution was prepared. SiO 2 , Fe 2 O 3 , Al 2 O 3 , MnO and rare earth metals were determined by atomic absorption spectrophotometry, CaO, MgO and Ce 2 O 3 by titration, ThO 2 by colorimetry, and La 2 O 3 by flame photometry respectively. For sample solution treated with hydrofluoric acid and sulfuric acid. Na 2 O and K 2 O were determined by atomic absorption spectrophotometry, TiO 2 and P 2 O 5 by colorimetry. Chemical analyses for four samples were carried out and gave consistent results. (author)

  16. An extended chemical analysis of gallstone

    OpenAIRE

    Chandran, P.; Kuchhal, N. K.; Garg, P.; Pundir, C. S.

    2007-01-01

    Chemical composition of gall stones is essential for aetiopathogensis of gallstone disease. We have reported quantitative chemical analysis of total cholesterol bilirubin, calcium, iron and inorganic phosphate in 120 gallstones from haryana. To extend this chemical analysis of gall stones by studying more cases and by analyzing more chemical constituents. A quantitative chemical analysis of total cholesterol, total bilirubin, fatty acids, triglycerides, phospholipids, bile acids, soluble prot...

  17. Chemical analysis as production guide

    International Nuclear Information System (INIS)

    Bouzigues, H.; Fontaine, A.; Patigny, P.

    1975-01-01

    All piloting data of chemical processing plants are based on the results of analysis. The first part of this article describes a system of analysers adapted to the needs of the Pierrelatte plant, with management of signals collected by the factory computer. Part two shows the influence of analytical development in the establishment of material balance sheets for the Marcoule spent fuel processing plant. Part three stresses the contribution of the automation of analytical test processes at the La Hague spent fuel processing plant. In all three cases the progress in analytical methods greatly improves the safety, reliability and response time of the various operations [fr

  18. Activation and chemical analysis of drinking waters

    International Nuclear Information System (INIS)

    Sharma, H.K.; Mittal, V.K.; Sahota, H.S.

    1989-01-01

    Ground water samples from Patiala city have been analysed for 22 trace elements using neutron activation analysis and for seven chemical parameters using standard techniques. It was found that alkali and alkaline earth metals have high concentrations in all samples whereas the concentrations of toxic metals are low in the majority of samples. However, chromium and cadmium concentrations are higher in ground water taken from the industrial belt of the city. This indicates that the overall level of pollution is low, but that some measures are still needed to inhibit various industries from polluting the ground water. (author)

  19. Advanced Techniques of Stress Analysis

    Directory of Open Access Journals (Sweden)

    Simion TATARU

    2013-12-01

    Full Text Available This article aims to check the stress analysis technique based on 3D models also making a comparison with the traditional technique which utilizes a model built directly into the stress analysis program. This comparison of the two methods will be made with reference to the rear fuselage of IAR-99 aircraft, structure with a high degree of complexity which allows a meaningful evaluation of both approaches. Three updated databases are envisaged: the database having the idealized model obtained using ANSYS and working directly on documentation, without automatic generation of nodes and elements (with few exceptions, the rear fuselage database (performed at this stage obtained with Pro/ ENGINEER and the one obtained by using ANSYS with the second database. Then, each of the three databases will be used according to arising necessities.The main objective is to develop the parameterized model of the rear fuselage using the computer aided design software Pro/ ENGINEER. A review of research regarding the use of virtual reality with the interactive analysis performed by the finite element method is made to show the state- of- the-art achieved in this field.

  20. Predictive analysis of the influence of the chemical composition and pre-processing regimen on structural properties of steel alloys using machine learning techniques

    Science.gov (United States)

    Krishnamurthy, Narayanan; Maddali, Siddharth; Romanov, Vyacheslav; Hawk, Jeffrey

    We present some structural properties of multi-component steel alloys as predicted by a random forest machine-learning model. These non-parametric models are trained on high-dimensional data sets defined by features such as chemical composition, pre-processing temperatures and environmental influences, the latter of which are based upon standardized testing procedures for tensile, creep and rupture properties as defined by the American Society of Testing and Materials (ASTM). We quantify the goodness of fit of these models as well as the inferred relative importance of each of these features, all with a conveniently defined metric and scale. The models are tested with synthetic data points, generated subject to the appropriate mathematical constraints for the various features. By this we highlight possible trends in the increase or degradation of the structural properties with perturbations in the features of importance. This work is presented as part of the Data Science Initiative at the National Energy Technology Laboratory, directed specifically towards the computational design of steel alloys.

  1. Techniques for Automated Performance Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Marcus, Ryan C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-09-02

    The performance of a particular HPC code depends on a multitude of variables, including compiler selection, optimization flags, OpenMP pool size, file system load, memory usage, MPI configuration, etc. As a result of this complexity, current predictive models have limited applicability, especially at scale. We present a formulation of scientific codes, nodes, and clusters that reduces complex performance analysis to well-known mathematical techniques. Building accurate predictive models and enhancing our understanding of scientific codes at scale is an important step towards exascale computing.

  2. Applications of neutron activation analysis technique

    International Nuclear Information System (INIS)

    Jonah, S. A.

    2000-07-01

    The technique was developed as far back as 1936 by G. Hevesy and H. Levy for the analysis of Dy using an isotopic source. Approximately 40 elements can be analyzed by instrumental neutron activation analysis (INNA) technique with neutrons from a nuclear reactor. By applying radiochemical separation, the number of elements that can be analysed may be increased to almost 70. Compared with other analytical methods used in environmental and industrial research, NAA has some unique features. These are multi-element capability, rapidity, reproducibility of results, complementarity to other methods, freedom from analytical blank and independency of chemical state of elements. There are several types of neutron sources namely: nuclear reactors, accelerator-based and radioisotope-based sources, but nuclear reactors with high fluxes of neutrons from the fission of 235 U give the most intense irradiation, and hence the highest available sensitivities for NAA. In this paper, the applications of NAA of socio-economic importance are discussed. The benefits of using NAA and related nuclear techniques for on-line applications in industrial process control are highlighted. A brief description of the NAA set-ups at CERT is enumerated. Finally, NAA is compared with other leading analytical techniques

  3. Chemical detection, identification, and analysis system

    International Nuclear Information System (INIS)

    Morel, R.S.; Gonzales, D.; Mniszewski, S.

    1990-01-01

    The chemical detection, identification, and analysis system (CDIAS) has three major goals. The first is to display safety information regarding chemical environment before personnel entry. The second is to archive personnel exposure to the environment. Third, the system assists users in identifying the stage of a chemical process in progress and suggests safety precautions associated with that process. In addition to these major goals, the system must be sufficiently compact to provide transportability, and it must be extremely simple to use in order to keep user interaction at a minimum. The system created to meet these goals includes several pieces of hardware and the integration of four software packages. The hardware consists of a low-oxygen, carbon monoxide, explosives, and hydrogen sulfide detector; an ion mobility spectrometer for airborne vapor detection; and a COMPAQ 386/20 portable computer. The software modules are a graphics kernel, an expert system shell, a data-base management system, and an interface management system. A supervisory module developed using the interface management system coordinates the interaction of the other software components. The system determines the safety of the environment using conventional data acquisition and analysis techniques. The low-oxygen, carbon monoxide, hydrogen sulfide, explosives, and vapor detectors are monitored for hazardous levels, and warnings are issued accordingly

  4. Temperature lowering in cryogenic chemical-synthesis techniques and system

    International Nuclear Information System (INIS)

    Martinez, H.E.; Nelson, T.O.; Vikdal, L.N.

    1993-01-01

    When evaluating a chemical synthesis process for a reaction that occurs on the cryogenically cooled walls, it is sometimes necessary to reduce the wall temperatures to enhance the chemical process. To evaluate the chemical process at lower than atmospheric boiling of liquid nitrogen, we built a system and used it to reduce the temperature of the liquid nitrogen. The technique of lowering the liquid nitrogen temperature by reducing the pressure of the boil-off is established knowledge. This paper presents the engineering aspects of the system, design features, equipment requirements, methods of control, and results of the chemical synthesis. The heat input to the system was ∼400 watts, placing a relatively large demand on the pumping system. Our system is a scale-up of the small laboratory experiment, and it provides the information needed to design an effective system. The major problem encountered was the large quantity of liquid escaping the system during the processing, placing a large gas load on the vacuum system

  5. Lifetimes of organic photovoltaics: Combining chemical and physical characterisation techniques to study degradation mechanisms

    DEFF Research Database (Denmark)

    Norrman, K.; Larsen, N.B.; Krebs, Frederik C

    2006-01-01

    Degradation mechanisms of a photovoltaic device with an Al/C-60/C-12-PSV/PEDOT:PSS/ITO/glass geometry was studied using a combination of in-plane physical and chemical analysis techniques: TOF-SIMS, AFM, SEM, interference microscopy and fluorescence microscopy. A comparison was made between...

  6. Chemical analysis: modern instrumentation methods and techniques

    National Research Council Canada - National Science Library

    Rouessac, Francis; Rouessac, Annick

    2007-01-01

    ... regulation 2.3 Sample introduction and the injection chamber 2.4 Thermostatically controlled oven 2.5 Columns 2.6 Stationary phases 2.7 Principal gas chromatographic detectors 2.8 Detectors provi...

  7. Techniques for Analysis of Plant Phenolic Compounds

    Directory of Open Access Journals (Sweden)

    Thomas H. Roberts

    2013-02-01

    Full Text Available Phenolic compounds are well-known phytochemicals found in all plants. They consist of simple phenols, benzoic and cinnamic acid, coumarins, tannins, lignins, lignans and flavonoids. Substantial developments in research focused on the extraction, identification and quantification of phenolic compounds as medicinal and/or dietary molecules have occurred over the last 25 years. Organic solvent extraction is the main method used to extract phenolics. Chemical procedures are used to detect the presence of total phenolics, while spectrophotometric and chromatographic techniques are utilized to identify and quantify individual phenolic compounds. This review addresses the application of different methodologies utilized in the analysis of phenolic compounds in plant-based products, including recent technical developments in the quantification of phenolics.

  8. Recent Microextraction Techniques for Determination and Chemical Speciation of Selenium

    Directory of Open Access Journals (Sweden)

    Ibrahim Ahmed S. A.

    2017-05-01

    Full Text Available Research designed to improve extraction has led to the development of microextraction techniques (ME, which involve simple, low cost, and effective preconcentrationof analytes in various matrices. This review is concerned with the principles and theoretical background of ME, as well as the development of applications for selenium analysis during the period from 2008 to 2016. Among all ME, dispersive liquid-liquid microextraction was found to be most favorable for selenium. On the other hand, atomic absorption spectrometry was the most frequently used instrumentation. Selenium ME have rarely been coupled to spectrophotometry and X-ray spectrophotometry methods, and there is no published application of ME with electrochemical techniques. We strongly support the idea of using a double preconcentration process, which consists of microextraction prior to preconcentration, followed by selenium determination using cathodic stripping voltammetry (ME-CSV. More attention should focus on the development of accurate, precise, and green methods for selenium analysis.

  9. Application of physical and chemical characterization techniques to metallic powders

    International Nuclear Information System (INIS)

    Slotwinski, J. A.; Watson, S. S.; Stutzman, P. E.; Ferraris, C. F.; Peltz, M. A.; Garboczi, E. J.

    2014-01-01

    Systematic studies have been carried out on two different powder materials used for additive manufacturing: stainless steel and cobalt-chrome. The characterization of these powders is important in NIST efforts to develop appropriate measurements and standards for additive materials and to document the property of powders used in a NIST-led additive manufacturing material round robin. An extensive array of characterization techniques was applied to these two powders, in both virgin and recycled states. The physical techniques included laser diffraction particle size analysis, X-ray computed tomography for size and shape analysis, and optical and scanning electron microscopy. Techniques sensitive to chemistry, including X-ray diffraction and energy dispersive analytical X-ray analysis using the X-rays generated during scanning electron microscopy, were also employed. Results of these analyses will be used to shed light on the question: how does virgin powder change after being exposed to and recycled from one or more additive manufacturing build cycles? In addition, these findings can give insight into the actual additive manufacturing process

  10. Chemical analysis of cyanide in cyanidation process: review of methods

    International Nuclear Information System (INIS)

    Nova-Alonso, F.; Elorza-Rodriguez, E.; Uribe-Salas, A.; Perez-Garibay, R.

    2007-01-01

    Cyanidation, the world wide method for precious metals recovery, the chemical analysis of cyanide, is a very important, but complex operation. Cyanide can be present forming different species, each of them with different stability, toxicity, analysis method and elimination technique. For cyanide analysis, there exists a wide selection of analytical methods but most of them present difficulties because of the interference of species present in the solution. This paper presents the different available methods for chemical analysis of cyanide: titration, specific electrode and distillation, giving special emphasis on the interferences problem, with the aim of helping in the interpretation of the results. (Author)

  11. Proposed minimum reporting standards for chemical analysis Chemical Analysis Working Group (CAWG) Metabolomics Standards Initiative (MSI)

    Science.gov (United States)

    Amberg, Alexander; Barrett, Dave; Beale, Michael H.; Beger, Richard; Daykin, Clare A.; Fan, Teresa W.-M.; Fiehn, Oliver; Goodacre, Royston; Griffin, Julian L.; Hankemeier, Thomas; Hardy, Nigel; Harnly, James; Higashi, Richard; Kopka, Joachim; Lane, Andrew N.; Lindon, John C.; Marriott, Philip; Nicholls, Andrew W.; Reily, Michael D.; Thaden, John J.; Viant, Mark R.

    2013-01-01

    There is a general consensus that supports the need for standardized reporting of metadata or information describing large-scale metabolomics and other functional genomics data sets. Reporting of standard metadata provides a biological and empirical context for the data, facilitates experimental replication, and enables the re-interrogation and comparison of data by others. Accordingly, the Metabolomics Standards Initiative is building a general consensus concerning the minimum reporting standards for metabolomics experiments of which the Chemical Analysis Working Group (CAWG) is a member of this community effort. This article proposes the minimum reporting standards related to the chemical analysis aspects of metabolomics experiments including: sample preparation, experimental analysis, quality control, metabolite identification, and data pre-processing. These minimum standards currently focus mostly upon mass spectrometry and nuclear magnetic resonance spectroscopy due to the popularity of these techniques in metabolomics. However, additional input concerning other techniques is welcomed and can be provided via the CAWG on-line discussion forum at http://msi-workgroups.sourceforge.net/ or http://Msi-workgroups-feedback@lists.sourceforge.net. Further, community input related to this document can also be provided via this electronic forum. PMID:24039616

  12. Reliability analysis techniques in power plant design

    International Nuclear Information System (INIS)

    Chang, N.E.

    1981-01-01

    An overview of reliability analysis techniques is presented as applied to power plant design. The key terms, power plant performance, reliability, availability and maintainability are defined. Reliability modeling, methods of analysis and component reliability data are briefly reviewed. Application of reliability analysis techniques from a design engineering approach to improving power plant productivity is discussed. (author)

  13. Development of environmental sample analysis techniques for safeguards

    International Nuclear Information System (INIS)

    Magara, Masaaki; Hanzawa, Yukiko; Esaka, Fumitaka

    1999-01-01

    JAERI has been developing environmental sample analysis techniques for safeguards and preparing a clean chemistry laboratory with clean rooms. Methods to be developed are a bulk analysis and a particle analysis. In the bulk analysis, Inductively-Coupled Plasma Mass Spectrometer or Thermal Ionization Mass Spectrometer are used to measure nuclear materials after chemical treatment of sample. In the particle analysis, Electron Probe Micro Analyzer and Secondary Ion Mass Spectrometer are used for elemental analysis and isotopic analysis, respectively. The design of the clean chemistry laboratory has been carried out and construction will be completed by the end of March, 2001. (author)

  14. Active sampling technique to enhance chemical signature of buried explosives

    Science.gov (United States)

    Lovell, John S.; French, Patrick D.

    2004-09-01

    Deminers and dismounted countermine engineers commonly use metal detectors, ground penetrating radar and probes to locate mines. Many modern landmines have a very low metal content, which severely limits the effectiveness of metal detectors. Canines have also been used for landmine detection for decades. Experiments have shown that canines smell the explosives which are known to leak from most types of landmines. The fact that dogs can detect landmines indicates that vapor sensing is a viable approach to landmine detection. Several groups are currently developing systems to detect landmines by "sniffing" for the ultra-trace explosive vapors above the soil. The amount of material that is available to passive vapor sensing systems is limited to no more than the vapor in equilibrium with the explosive related chemicals (ERCs) distributed in the surface soils over and near the landmine. The low equilibrium vapor pressure of TNT in the soil/atmosphere boundary layer and the limited volume of the boundary layer air imply that passive chemical vapor sensing systems require sensitivities in the picogram range, or lower. ADA is working to overcome many of the limitations of passive sampling methods, by the use of an active sampling method that employs a high-powered (1,200+ joules) strobe lamp to create a highly amplified plume of vapor and/or ERC-bearing fine particulates. Initial investigations have demonstrated that this approach can amplify the detectability of TNT by two or three orders of magnitude. This new active sampling technique could be used with any suitable explosive sensor.

  15. Techniques for chemical characterization of zirconium and its alloys

    International Nuclear Information System (INIS)

    Iyer, K.V.; Bassan, M.K.T.; Sudersanan, M.

    2002-01-01

    Chemical characterization of zirconium and its alloys such as zircaloy, Zr-Nb, etc for minor and trace constituents like Nb, Ti, Fe, Cr, Ni, Sn, Al etc has been carried out. Zirconium, being a major constituent, has been determined by gravimetry as zirconium oxide while other constituents like Nb, Ti, Fe have been determined by spectrophotometric methods. Other metals of importance at trace level have been estimated by AAS or ICPAES. The judicious use of both conventional and modern instrumental methods of analysis helps in the characterization of zirconium and its alloys for various major and minor constituents. The role of matrix effect in the determination was also investigated and methods have been worked out based on a preliminary separation of zirconium by a hydroxide precipitation. (author)

  16. Chemical analysis of the Fornax Dwarf galaxy

    NARCIS (Netherlands)

    Letarte, Bruno

    2007-01-01

    This thesis is entitled “Chemical Analysis of the Fornax Dwarf Galaxy”, and it’s main goal is to determine what are the chemical elements present in the stars of this galaxy in order to try and understand it’s evolution. Galaxies are not “static” objects, they move, form stars and can interact with

  17. Chemical analysis of reactor and commercial columbium

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    The methods cover the chemical analysis of reactor and commercial columbium having chemical compositions within specified limits. The following analytical procedures are discussed along with apparatus, reagents, photometric practice, safety precautions, sampling, and rounding calculated values: nitrogen, by distillation (photometric) method; molybdenum and tungsten by the dithiol (photometric) method; iron by the 1,10-phenanthroline (photometric) method

  18. SnS thin films deposited by chemical bath deposition, dip coating and SILAR techniques

    Science.gov (United States)

    Chaki, Sunil H.; Chaudhary, Mahesh D.; Deshpande, M. P.

    2016-05-01

    The SnS thin films were synthesized by chemical bath deposition (CBD), dip coating and successive ionic layer adsorption and reaction (SILAR) techniques. In them, the CBD thin films were deposited at two temperatures: ambient and 70 °C. The energy dispersive analysis of X-rays (EDAX), X-ray diffraction (XRD), Raman spectroscopy, scanning electron microscopy (SEM) and optical spectroscopy techniques were used to characterize the thin films. The electrical transport properties studies on the as-deposited thin films were done by measuring the I-V characteristics, DC electrical resistivity variation with temperature and the room temperature Hall effect. The obtained results are deliberated in this paper.

  19. New decontamination techniques: chemical gels, electropolishing and abrasives

    International Nuclear Information System (INIS)

    Brunel, G.; Gauchon, J.P.; Kervegant, Y.; Josso, F.

    1991-01-01

    The decommissioning of nuclear installations requires decontamination techniques that are efficient, simple to apply and producing a small amount of wastes, which are easy to process. With a view to this, three decontamination methods, which appear to be particularly suited to decommissioning, have been studied. These three methods are: - spraying of gels carrying chemical decontaminating agents, - electropolishing with a swab device, - abrasives blasting. After parametric tests on non-radioactive and active samples, the industrial application of these methods in the dismantling of installations was studied. These industrial applications concern: - decontamination of pieces coming from the German BWR ISAR by immersion and gel spraying, - decontamination, mainly by gel spraying, and dismantling of the BRENNILIS bituminisation plant, - decontamination of part of the cooling circuit of the graphite gas reactor G2 by gel spraying, - decontamination of a component of the FBR SuperPhenix, using dry abrasives blasting. During the first three applications, generated secondary wastes volume and form were determined. 33 tabs., 16 figs., 12 refs

  20. Optical MEMS for chemical analysis and biomedicine

    CERN Document Server

    Jiang, Hongrui

    2016-01-01

    This book describes the current state of optical MEMS in chemical and biomedical analysis and brings together current trends and highlights topics representing the most exciting progress in recent years in the field.

  1. Efficiency of modified chemical remediation techniques for soil contaminated by organochlorine pesticides

    Science.gov (United States)

    Correa-Torres, S. N.; Kopytko, M.; Avila, S.

    2016-07-01

    This study reports the optimization of innovation chemical techniques in order to improve the remediation of soils contaminated with organochloride pesticides. The techniques used for remediation were dehalogenation and chemical oxidation in soil contaminated by pesticides. These techniques were applied sequentially and combined to evaluate the design optimize the concentration and contact time variables. The soil of this study was collect in cotton crop zone in Agustin Codazzi municipality, Colombia, and its physical properties was measure. The modified dehalogenation technique of EPA was applied on the contaminated soil by adding Sodium Bicarbonate solution at different concentrations and rates during 4, 7 and 14 days, subsequently oxidation technique was implemented by applying a solution of KMnO4 at different concentration and reaction times. Organochlorine were detected by Gas Chromatography analysis coupled Mass Spectrometry and its removals were between 85.4- 90.0% of compounds such as 4, 4’-DDT, 4,4’-DDD, 4,4-DDE, trans-Clordane y Endrin. These results demonstrate that the technique of dehalogenation with oxidation chemistry can be used for remediation soils contaminated by organochloride pesticides.

  2. Determination of Methylmercury Traces in Biological Matrix: Chemical Extraction and Nuclear Quantification with the Neutron Activation Analysis Technique; Determinacion de Trazas de Metilmercurio en Matriz Biologica: Extracion Quimica y Cuantificacion Mediante la Tecnica Nuclear de Analisis por Activacion Neutronica (AANI)

    Energy Technology Data Exchange (ETDEWEB)

    Soldati, A L [Instituto Balseiro, Universidad Nacional de Cuyo, Centro Atomico Bariloche (Argentina)

    2002-07-01

    Mercury is present in the environment as a result of the human and natural activities.The total amount of Hg present in the biosphere has been incremented three times since the industrial era, and now it is affecting in a global sense all the ecosystem.One of the main entrance of Hg in the human diet is the consumption of fish and other marine creatures.Most of the ingested Hg is mono methylmercury (MeHg), which is one of the most toxic forms in which this element could be found because it crosses membranes.Since the toxicity levels are low, the determination of concentrations of total Hg and Me Hg require very careful sampling, sample conditioning and analytical procedures to prevent either losses or contamination, or the degradation of the Hg species.In this work, we implemented a chemical Me Hg extraction procedure, using a ionic exchange resin, with three different types of fish tissue: muscle, liver and hepato pancreas.After Me Hg extraction, the determination and quantification was made by Instrumental Neutron Activation Analysis, by measuring the {sup 197} Au, y el {sup 203} Tl deexcitation s, created through the radioactive decay of the isotopes {sup 197} Hg y {sup 203} Hg.The influence of several parameters on the overall extraction process, such as velocity of passage through the ionic exchange column and the acid concentration used in the extraction was evaluated.Regarding the INAA determinations, a choice was made for the irradiation, decay and counting times, neutron and gamma doses, and the counting geometry The detection limit found for this technique (dry weight) is 140 pg MeHg/g. The Hg contents of the muscle samples were measured with the 279 keV emission of the product of the {sup 202} Hg(n,g){sup 203} Hg reaction, with a recovery of (100 {+-} 13)%. Liver and Hepato pancreas samples were measured with the 77 keV gamma emission of the {sup 197} Hg, checking this result with the 67 y 69 keV X emissions from the same isotope.The liver samples needed

  3. Chemical analysis of water in hydrogeology

    International Nuclear Information System (INIS)

    Flakova, R.; Zenisova, Z.; Seman, M.

    2010-01-01

    The aim of the monograph is to give complete information on the chemical analysis of water hydrogeology not only for the students program of Geology study (Bachelor degree study), Engineering Geology and Hydrogeology (Master's degree study) and Engineering Geology (doctoral level study), but also for students from other colleges and universities schools in Slovakia, as well as in the Czech Republic, dealing with the chemical composition of water and its quality, from different perspectives. The benefit would be for professionals with hydrogeological, water and environmental practices, who can find there all the necessary information about proper water sampling, the units used in the chemical analysis of water, expressing the proper chemical composition of water in its various parameters through classification of chemical composition of the water up to the basic features of physical chemistry at thermodynamic calculations and hydrogeochemical modelling.

  4. Chemical methods of rock analysis

    National Research Council Canada - National Science Library

    Jeffery, P. G; Hutchison, D

    1981-01-01

    A practical guide to the methods in general use for the complete analysis of silicate rock material and for the determination of all those elements present in major, minor or trace amounts in silicate...

  5. Utilization of chemical derivatives in activation analysis

    International Nuclear Information System (INIS)

    Ehmann, W.D.

    1990-01-01

    Derivative activation analysis (DAA) is a method to enhance the sensitivity of nuclear activation analysis for the more elusive elements. It may also allow a degree of chemical speciation for the element of interest. DAA uses a preirradiation chemical reaction on the sample to initiate the formation of, or an exchange with, a chemical complex which contains a surrogate element, M. As a result, the amount of the element or the chemical species to be determined, X, is now represented by measurement of the amount of the surrogate element, M, that is made part of, or released by the complex species. The surrogate element is selected for its superior properties for nuclear activation analysis and the absence of interference reaction in its final determination by instrumental neutron activation analysis (INAA) after some preconcentration or separation chemistry. Published DAA studies have been limited to neutron activation analysis. DAA can offer the analyst some important advantages. It can determine elements, functional groups, or chemical species which cannot be determined directly by INAA, fast neutron activation analysis (FNAA), prompt gamma neutron activation analysis (PGNAA), or charged particle activation analysis (CPAA) procedures. When compared with conventional RNAA, there are fewer precautions with respect to handling of intensely radioactive samples, since the chemistry is done before the irradiation. The preirradiation chemistry may also eliminate many interferences that might occur in INAA and, through use of an appropriate surrogate element, can place the analytical gamma-ray line in an interference-free region of the gamma-ray spectrum

  6. Nuclear analysis techniques and environmental sciences

    International Nuclear Information System (INIS)

    1997-10-01

    31 theses are collected in this book. It introduced molecular activation analysis micro-PIXE and micro-probe analysis, x-ray fluorescence analysis and accelerator mass spectrometry. The applications about these nuclear analysis techniques are presented and reviewed for environmental sciences

  7. Analysis of archaeological pieces with nuclear techniques

    International Nuclear Information System (INIS)

    Tenorio, D.

    2002-01-01

    In this work nuclear techniques such as Neutron Activation Analysis, PIXE, X-ray fluorescence analysis, Metallography, Uranium series, Rutherford Backscattering for using in analysis of archaeological specimens and materials are described. Also some published works and thesis about analysis of different Mexican and Meso american archaeological sites are referred. (Author)

  8. Spectroscopic Chemical Analysis Methods and Apparatus

    Science.gov (United States)

    Hug, William F. (Inventor); Reid, Ray D. (Inventor); Bhartia, Rohit (Inventor); Lane, Arthur L. (Inventor)

    2018-01-01

    Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

  9. A multi-technique approach to assess chemical speciation of phosphate in soils

    Science.gov (United States)

    Belchior Abdala, Dalton; Rodrigues, Marcos; Herrera, Wilfrand; Pavinato, Paulo Sergio

    2017-04-01

    Soil scientists see chemical characterization of phosphorus (e.g., chemical speciation) as a winning strategy to increase phosphorus use efficiency in agriculture, to understand the fate of applied P fertilizer in soils and to devise strategies to minimize P losses to the environment. Phosphorus (P) is majorly presented in soils as phosphate, bound to mineral components of soils such as Al-, Ca- and Fe-(hydr)oxides or associated with organic molecules, being thus generally referred to as organic phosphates. In addition, because of the turnover of P between plants and microbes, it delivers P back to soils as a mixture of species with high spatial and chemical heterogeneity, adding complexity to the determination of the P species contained in environmental samples. Therefore, due to the variety of forms that phosphate can present in soils, its precise chemical characterization can only be achieved using a set of analytical techniques. Although established methodologies (e. g., soil test P, sequential chemical fractionation, P isotherms) have been useful to subsidize information for the establishment of policies and guidelines for soil management and P fertilizers use, they have failed to provide detailed information on P chemistry and reactivity in soils in a more satisfactory manner, which are critical to predict P bioavailability to plants and loss potential to the environment. More recently, the association of wet chemistry analysis with spectroscopy and microscopy techniques has arguably represented the most successful means to chemically speciate phosphate in soils. This is because using qualitative (chemical speciation), quantitative (chemical fractionation) and spatial (microscopy) data allows for triangulation of information, thereby reducing bias and increasing validity of the results. The analysis framework that we propose in this study includes the use of (i) sequential chemical fractionation of soil P to determine the partitioning of P within the

  10. Chemical solution deposition techniques for epitaxial growth of complex oxides

    NARCIS (Netherlands)

    ten Elshof, Johan E.; Koster, G.; Huijben, Mark; Rijnders, G.

    2015-01-01

    The chemical solution deposition (CSD) process is a wet-chemical process that is employed to fabricate a wide variety of amorphous and crystalline oxide thin films. This chapter describes the typical steps in a CSD process and their influence on the final microstructure and properties of films, and

  11. Descriptive, metallographic and chemical study of cooper-alloy points found at the grave of one member of the Sican elite, Lambayeque - Peru, using optical microscopy techniques and neutron activation analysis

    International Nuclear Information System (INIS)

    Vetter, L.; Carcedo, P.; Cutipa, S.; Montoya, E.

    1997-01-01

    This paper offers a description as well as physical and morphological analyses of 489 points found inside the grave of one of the elite members of Sican (900 - 1110 dC). A metallographic study of one of the points is also carried out, plus the multielemental-quantitative chemical analysis of twelve items from the same grave. In addition, four points of the same culture from the Museo Nacional de Arqueologia, Antropologia e Historia of Peru are also analyzed

  12. Multitracer techniques: applications in chemical and life sciences

    International Nuclear Information System (INIS)

    Nayak, Dalia

    2001-01-01

    The scope and approaches of the 'multitracer technique' have briefly been reviewed. The various aspects of the 'multitracer technique' include, the methods of accelerator production of 'multitracers' and their separation, the application of this technique in the study of adsorption of metal ions on solid surfaces and in the study of distribution of trace elements in plants and animals

  13. Event tree analysis using artificial intelligence techniques

    International Nuclear Information System (INIS)

    Dixon, B.W.; Hinton, M.F.

    1985-01-01

    Artificial Intelligence (AI) techniques used in Expert Systems and Object Oriented Programming are discussed as they apply to Event Tree Analysis. A SeQUence IMPortance calculator, SQUIMP, is presented to demonstrate the implementation of these techniques. Benefits of using AI methods include ease of programming, efficiency of execution, and flexibility of application. The importance of an appropriate user interface is stressed. 5 figs

  14. TV content analysis techniques and applications

    CERN Document Server

    Kompatsiaris, Yiannis

    2012-01-01

    The rapid advancement of digital multimedia technologies has not only revolutionized the production and distribution of audiovisual content, but also created the need to efficiently analyze TV programs to enable applications for content managers and consumers. Leaving no stone unturned, TV Content Analysis: Techniques and Applications provides a detailed exploration of TV program analysis techniques. Leading researchers and academics from around the world supply scientifically sound treatment of recent developments across the related subject areas--including systems, architectures, algorithms,

  15. Statistical evaluation of vibration analysis techniques

    Science.gov (United States)

    Milner, G. Martin; Miller, Patrice S.

    1987-01-01

    An evaluation methodology is presented for a selection of candidate vibration analysis techniques applicable to machinery representative of the environmental control and life support system of advanced spacecraft; illustrative results are given. Attention is given to the statistical analysis of small sample experiments, the quantification of detection performance for diverse techniques through the computation of probability of detection versus probability of false alarm, and the quantification of diagnostic performance.

  16. Controlling the accuracy of chemical analysis

    International Nuclear Information System (INIS)

    Suschny, O.; Danesi, P.R.

    1991-01-01

    The involvement of the IAEA in quantitative analysis began in the early 1960's with radiochemical work connected with the environment. It than expanded to cover analysis (mostly by nuclear techniques) of samples for projects associated with human health, agriculture, hydrology and international safeguards. This article highlights the IAEA activities in the field of quality control in quantitative analysis

  17. Chemical analysis of high purity graphite

    International Nuclear Information System (INIS)

    1993-03-01

    The Sub-Committee on Chemical Analysis of Graphite was organized in April 1989, under the Committee on Chemical Analysis of Nuclear Fuels and Reactor Materials, JAERI. The Sub-Committee carried out collaborative analyses among eleven participating laboratories for the certification of the Certified Reference Materials (CRMs), JAERI-G5 and G6, after developing and evaluating analytical methods during the period of September 1989 to March 1992. The certified values were given for ash, boron and silicon in the CRM based on the collaborative analysis. The values for ten elements (Al, Ca, Cr, Fe, Mg, Mo, Ni, Sr, Ti, V) were not certified, but given for information. Preparation, homogeneity testing and chemical analyses for certification of reference materials were described in this paper. (author) 52 refs

  18. Constrained principal component analysis and related techniques

    CERN Document Server

    Takane, Yoshio

    2013-01-01

    In multivariate data analysis, regression techniques predict one set of variables from another while principal component analysis (PCA) finds a subspace of minimal dimensionality that captures the largest variability in the data. How can regression analysis and PCA be combined in a beneficial way? Why and when is it a good idea to combine them? What kind of benefits are we getting from them? Addressing these questions, Constrained Principal Component Analysis and Related Techniques shows how constrained PCA (CPCA) offers a unified framework for these approaches.The book begins with four concre

  19. Chemical aspects of nuclear methods of analysis

    International Nuclear Information System (INIS)

    1985-01-01

    This final report includes papers which fall into three general areas: development of practical pre-analysis separation techniques, uranium/thorium separation from other elements for analytical and processing operations, and theory and mechanism of separation techniques. A separate abstract was prepared for each of the 9 papers

  20. Molecular activation analysis for chemical species studies

    International Nuclear Information System (INIS)

    Chai Zhifang; Mao Xueying; Wang Yuqi; Sun Jingxin; Qian Qingfang; Hou Xiaolin; Zhang Peiqun; Chen Chunying; Feng Weiyu; Ding Wenjun; Li Xiaolin; Li Chunsheng; Dai Xiongxin

    2001-01-01

    The Molecular Activation Analysis (MAA) mainly refers to an activation analysis method that is able to provide information about the chemical species of elements in systems of interest, though its exact definition has remained to be assigned. Its development is strongly stimulated by the urgent need to know the chemical species of elements, because the bulk contents or concentrations are often insignificant for judging biological, environmental or geochemical effects of elements. In this paper, the features, methodology and limitation of MAA were outlined. Further, the up-to-date MAA progress made in our laboratory was introduced as well. (author)

  1. Service activities of chemical analysis division

    International Nuclear Information System (INIS)

    Eom, Tae Yoon; Suh, Moo Yul; Park, Kyoung Kyun; Jung, Ki Suk; Joe, Kih Soo; Jee, Kwang Yong; Jung, Woo Sik; Sohn, Se Chul; Yeo, In Heong; Han, Sun Ho

    1988-12-01

    Progress of the Division during the year of 1988 was described on the service activities for various R and D projects carrying out in the Institute, for the fuel fabrication and conversion plant, and for the post-irradiation examination facility. Relevant analytical methodologies developed for the chemical analysis of an irradiated fuel, safeguards chemical analysis, and pool water monitoring were included such as chromatographic separation of lanthanides, polarographic determination of dissolved oxygen in water, and automation on potentiometric titration of uranium. Some of the laboratory manuals revised were also included in this progress report. (Author)

  2. The application of radiotracer technique for preconcentration neutron activation analysis

    International Nuclear Information System (INIS)

    Wang Xiaolin; Chen Yinliang; Sun Ying; Fu Yibei

    1995-01-01

    The application of radiotracer technique for preconcentration neutron activation analysis (Pre-NAA) are studied and the method for determination of chemical yield of Pre-NAA is developed. This method has been applied to determination of gold, iridium and rhenium in steel and rock samples and the contents of noble metal are in the range of 1-20 ng·g -1 (sample). In addition, the accuracy difference caused by determination of chemical yield between RNAA and Pre-NAA are also discussed

  3. Chemical analysis by nuclear methods. v. 2

    International Nuclear Information System (INIS)

    Alfassi, Z.B.

    1998-01-01

    'Chemical analysis by Nuclear Methods' is an effort of some renowned authors in field of nuclear chemistry and radiochemistry which is compiled by Alfassi, Z.B. and translated into Farsi version collected in two volumes. The second volume consists of the following chapters: Detecting ion recoil scattering and elastic scattering are dealt in the eleventh chapter, the twelfth chapter is devoted to nuclear reaction analysis using charged particles, X-ray emission is discussed at thirteenth chapter, the fourteenth chapter is about using ion microprobes, X-ray fluorescence analysis is discussed in the fifteenth chapter, alpha, beta and gamma ray scattering in chemical analysis are dealt in chapter sixteen, Moessbauer spectroscopy and positron annihilation are discussed in chapter seventeen and eighteen; The last two chapters are about isotope dilution analysis and radioimmunoassay

  4. An extended chemical analysis of gallstone.

    Science.gov (United States)

    Chandran, P; Kuchhal, N K; Garg, P; Pundir, C S

    2007-09-01

    Chemical composition of gall stones is essential for aetiopathogensis of gallstone disease. We have reported quantitative chemical analysis of total cholesterol bilirubin, calcium, iron and inorganic phosphate in 120 gallstones from haryana. To extend this chemical analysis of gall stones by studying more cases and by analyzing more chemical constituents. A quantitative chemical analysis of total cholesterol, total bilirubin, fatty acids, triglycerides, phospholipids, bile acids, soluble proteins, sodium potassium, magnesium, copper, oxalate and chlorides of biliary calculi (52 cholesterol, 76 mixed and 72 pigment) retrieved from surgical operation of 200 patients from Haryana state was carried out. Total cholesterol as the major component and total bilirubin, phospholipids, triglycerides, bile acids, fatty acids (esterified), soluble protein, calcium, magnesium, iron, copper, sodium, potassium, inorganic phosphate, oxalate and chloride as minor components were found in all types of calculi. The cholesterol stones had higher content of total cholesterol, phospholipids, fatty acids (esterified), inorganic phosphate and copper compared to mixed and pigment stones. The mixed stones had higher content of iron and triglycerides than to cholesterol and pigment stones. The pigment stones were richer in total bilirubin, bile acids, calcium, oxalate, magnesium, sodium, potassium, chloride and soluble protein compared to cholesterol and mixed stones. Although total cholesterol was a major component of cholesterol, mixed and pigment gall stone in Haryana, the content of most of the other lipids, cations and anions was different in different gall stones indicating their different mechanism of formation.

  5. Elemental analysis techniques using proton microbeam

    International Nuclear Information System (INIS)

    Sakai, Takuro; Oikawa, Masakazu; Sato, Takahiro

    2005-01-01

    Proton microbeam is a powerful tool for two-dimensional elemental analysis. The analysis is based on Particle Induced X-ray Emission (PIXE) and Particle Induced Gamma-ray Emission (PIGE) techniques. The paper outlines the principles and instruments, and describes the dental application has been done in JAERI Takasaki. (author)

  6. The collection and field chemical analysis of water samples

    International Nuclear Information System (INIS)

    Korte, N.E.; Ealey, D.T.; Hollenbach, M.H.

    1984-01-01

    A successful water sampling program requires a clear understanding of appropriate measurement and sampling procedures in order to obtain reliable field data and representative samples. It is imperative that the personnel involved have a thorough knowledge of the limitations of the techniques being used. Though this seems self-evident, many sampling and field-chemical-analysis programs are still not properly conducted. Recognizing these problems, the Department of Energy contracted with Bendix Field Engineering Corporation through the Technical Measurements Center to develop and select procedures for water sampling and field chemical analysis at waste sites. The fundamental causese of poor field programs are addressed in this paper, largely through discussion of specific field-measurement techniques and their limitations. Recommendations for improvement, including quality-assurance measures, are also presented

  7. Review of cleaning techniques and their effects on the chemical composition of foliar samples

    Energy Technology Data Exchange (ETDEWEB)

    Rossini Oliva, S.; Raitio, H.

    2003-07-01

    Chemical foliar analysis is a tool widely used to study tree nutrition and to monitor the impact and extent of air pollutants. This paper reviews a number of cleaning methods, and the effects of cleaning on foliar chemistry. Cleaning may include mechanical techniques such as the use of dry or moistened tissues, shaking, blowing, and brushing, or use various washing techniques with water or other solvents. Owing to the diversity of plant species, tissue differences, etc., there is no standard procedure for all kinds of samples. Analysis of uncleaned leaves is considered a good method for assessing the degree of air contamination because it provides an estimate of the element content of the deposits on leaf surfaces or when the analysis is aimed at the investigation of transfer of elements along the food chain. Sample cleaning is recommended in order (1) to investigate the transfer rate of chemical elements from soil to plants, (2) to qualify the washoff of dry deposition from foliage and (3) to separate superficially absorbed and biomass-incorporated elements. Since there is not a standard cleaning procedure for all kinds of samples and aims, it is advised to conduct a pilot study in order to be able to establish a cleaning procedure to provide reliable foliar data. (orig.)

  8. Techniques for sensitivity analysis of SYVAC results

    International Nuclear Information System (INIS)

    Prust, J.O.

    1985-05-01

    Sensitivity analysis techniques may be required to examine the sensitivity of SYVAC model predictions to the input parameter values, the subjective probability distributions assigned to the input parameters and to the relationship between dose and the probability of fatal cancers plus serious hereditary disease in the first two generations of offspring of a member of the critical group. This report mainly considers techniques for determining the sensitivity of dose and risk to the variable input parameters. The performance of a sensitivity analysis technique may be improved by decomposing the model and data into subsets for analysis, making use of existing information on sensitivity and concentrating sampling in regions the parameter space that generates high doses or risks. A number of sensitivity analysis techniques are reviewed for their application to the SYVAC model including four techniques tested in an earlier study by CAP Scientific for the SYVAC project. This report recommends the development now of a method for evaluating the derivative of dose and parameter value and extending the Kruskal-Wallis technique to test for interactions between parameters. It is also recommended that the sensitivity of the output of each sub-model of SYVAC to input parameter values should be examined. (author)

  9. Chemical fingerprint technique and its application in the ...

    African Journals Online (AJOL)

    The Gastrodia tuber and its active component, gastrodin, have many pharmacological effects. In this study, optimized high performance liquid chromatography (HPLC) parameters were employed to determine the chemical fingerprints and gastrodin content of nine Gastrodia tuber populations. Based on the degree of ...

  10. Failure analysis on a chemical waste pipe

    International Nuclear Information System (INIS)

    Ambler, J.R.

    1985-01-01

    A failure analysis of a chemical waste pipe illustrates how nuclear technology can spin off metallurgical consultant services. The pipe, made of zirconium alloy (Zr-2.5 wt percent Nb, UNS 60705), had cracked in several places, all at butt welds. A combination of fractography and metallography indicated delayed hydride cracking

  11. Calibrating Detailed Chemical Analysis of M dwarfs

    Science.gov (United States)

    Veyette, Mark; Muirhead, Philip Steven; Mann, Andrew; Brewer, John; Allard, France; Homeier, Derek

    2018-01-01

    The ability to perform detailed chemical analysis of Sun-like F-, G-, and K-type stars is a powerful tool with many applications including studying the chemical evolution of the Galaxy, assessing membership in stellar kinematic groups, and constraining planet formation theories. Unfortunately, complications in modeling cooler stellar atmospheres has hindered similar analysis of M-dwarf stars. Large surveys of FGK abundances play an important role in developing methods to measure the compositions of M dwarfs by providing benchmark FGK stars that have widely-separated M dwarf companions. These systems allow us to empirically calibrate metallicity-sensitive features in M dwarf spectra. However, current methods to measure metallicity in M dwarfs from moderate-resolution spectra are limited to measuring overall metallicity and largely rely on astrophysical abundance correlations in stellar populations. In this talk, I will discuss how large, homogeneous catalogs of precise FGK abundances are crucial to advancing chemical analysis of M dwarfs beyond overall metallicity to direct measurements of individual elemental abundances. I will present a new method to analyze high-resolution, NIR spectra of M dwarfs that employs an empirical calibration of synthetic M dwarf spectra to infer effective temperature, Fe abundance, and Ti abundance. This work is a step toward detailed chemical analysis of M dwarfs at a similar precision achieved for FGK stars.

  12. Microarray technology for major chemical contaminants analysis in food: current status and prospects.

    Science.gov (United States)

    Zhang, Zhaowei; Li, Peiwu; Hu, Xiaofeng; Zhang, Qi; Ding, Xiaoxia; Zhang, Wen

    2012-01-01

    Chemical contaminants in food have caused serious health issues in both humans and animals. Microarray technology is an advanced technique suitable for the analysis of chemical contaminates. In particular, immuno-microarray approach is one of the most promising methods for chemical contaminants analysis. The use of microarrays for the analysis of chemical contaminants is the subject of this review. Fabrication strategies and detection methods for chemical contaminants are discussed in detail. Application to the analysis of mycotoxins, biotoxins, pesticide residues, and pharmaceutical residues is also described. Finally, future challenges and opportunities are discussed.

  13. Flow analysis techniques for phosphorus: an overview.

    Science.gov (United States)

    Estela, José Manuel; Cerdà, Víctor

    2005-04-15

    A bibliographical review on the implementation and the results obtained in the use of different flow analytical techniques for the determination of phosphorus is carried out. The sources, occurrence and importance of phosphorus together with several aspects regarding the analysis and terminology used in the determination of this element are briefly described. A classification as well as a brief description of the basis, advantages and disadvantages of the different existing flow techniques, namely; segmented flow analysis (SFA), flow injection analysis (FIA), sequential injection analysis (SIA), all injection analysis (AIA), batch injection analysis (BIA), multicommutated FIA (MCFIA), multisyringe FIA (MSFIA) and multipumped FIA (MPFIA) is also carried out. The most relevant manuscripts regarding the analysis of phosphorus by means of flow techniques are herein classified according to the detection instrumental technique used with the aim to facilitate their study and obtain an overall scope. Finally, the analytical characteristics of numerous flow-methods reported in the literature are provided in the form of a table and their applicability to samples with different matrixes, namely water samples (marine, river, estuarine, waste, industrial, drinking, etc.), soils leachates, plant leaves, toothpaste, detergents, foodstuffs (wine, orange juice, milk), biological samples, sugars, fertilizer, hydroponic solutions, soils extracts and cyanobacterial biofilms are tabulated.

  14. A numerical technique for reactor subchannel analysis

    International Nuclear Information System (INIS)

    Fath, Hassan E.S.

    1983-01-01

    A numerical technique is developed for the solution of the transient boundary layer equations with a moving liquid-vapour interface boundary. The technique uses the finite difference method with the velocity components defined over an Eulerian mesh. A system of interface massless markers is defined where the markers move with the flow field according to a simple kinematic relation between the interface geometry and the fluid velocity. Different applications of nuclear engineering interest are reported with some available results. The present technique is capable of predicting the interface profile near the wall which is important in the reactor subchannel analysis

  15. Probabilistic risk analysis in chemical engineering

    International Nuclear Information System (INIS)

    Schmalz, F.

    1991-01-01

    In risk analysis in the chemical industry, recognising potential risks is considered more important than assessing their quantitative extent. Even in assessing risks, emphasis is not on the probability involved but on the possible extent. Qualitative assessment has proved valuable here. Probabilistic methods are used in individual cases where the wide implications make it essential to be able to assess the reliability of safety precautions. In this case, assessment therefore centres on the reliability of technical systems and not on the extent of a chemical risk. 7 figs

  16. Microfabricated Gas Phase Chemical Analysis Systems

    International Nuclear Information System (INIS)

    FRYE-MASON, GREGORY CHARLES; HELLER, EDWIN J.; HIETALA, VINCENT M.; KOTTENSTETTE, RICHARD; LEWIS, PATRICK R.; MANGINELL, RONALD P.; MATZKE, CAROLYN M.; WONG, CHUNGNIN C.

    1999-01-01

    A portable, autonomous, hand-held chemical laboratory ((micro)ChemLab(trademark)) is being developed for trace detection (ppb) of chemical warfare (CW) agents and explosives in real-world environments containing high concentrations of interfering compounds. Microfabrication is utilized to provide miniature, low-power components that are characterized by rapid, sensitive and selective response. Sensitivity and selectivity are enhanced using two parallel analysis channels, each containing the sequential connection of a front-end sample collector/concentrator, a gas chromatographic (GC) separator, and a surface acoustic wave (SAW) detector. Component design and fabrication and system performance are described

  17. Silicon doping techniques using chemical vapor dopant deposition

    NARCIS (Netherlands)

    Popadic, M.

    2009-01-01

    Ultrashallow junctions are essential for the achievement of superior transistor performance, both in MOSFET and bipolar transistors. The stringent demands require state-of-the-art fabrication techniques. At the same time, in a different context, the accurate fabrication of various n type doping

  18. Analysis of rocks involving the x-ray diffraction, infrared and thermal gravimetric techniques

    International Nuclear Information System (INIS)

    Ikram, M.; Rauf, M.A.; Munir, N.

    1998-01-01

    Chemical analysis of rocks and minerals are usually obtained by a number of analytical techniques. The purpose of present work is to investigate the chemical composition of the rock samples and also to find that how far the results obtained by different instrumental methods are closely related. Chemical tests wee performed before using the instrumental techniques in order to determined the nature of these rocks. The chemical analysis indicated mainly the presence of carbonate and hence the carbonate nature of these rocks. The x-ray diffraction, infrared spectroscopy and thermal gravimetric analysis techniques were used for the determination of chemical composition of these samples. The results obtained by using these techniques have shown a great deal of similarities. (author)

  19. MAKSIMA-CHEMIST: a program for Mass Action Kinetics Simulation by Automatic Chemical Equation Manipulation and Integration using Stiff Techniques

    International Nuclear Information System (INIS)

    Carver, M.B.; Hanley, D.V.; Chaplin, K.R.

    1979-02-01

    MAKSIMA-CHEMIST was written to compute the kinetics of simultaneous chemical reactions. The ordinary differential equations, which are automatically derived from the stated chemical equations, are difficult to integrate, as they are coupled in a highly nonlinear manner and frequently involve a large range in the magnitude of the reaction rates. They form a classic 'stiff' differential equaton set which can be integrated efficiently only by recently developed advanced techniques. The new program also contains provision for higher order chemical reactions, and has a dynamic storage and decision feature. This permits it to accept any number of chemical reactions and species, and choose an integraton scheme which will perform most efficiently within the available memory. Sparse matrix techniques are used when the size and structure of the equation set is suitable. Finally, a number of post-analysis options are available, including printer and Calcomp plots of transient response of selected species, and graphical representation of the reaction matrix. (auth)

  20. Positron annihilation spectroscopy for chemical analysis (PASCA). Chapter 9

    International Nuclear Information System (INIS)

    Cheng, K.L.; Jean, Y.C.

    1988-01-01

    This chapter gives an up to date overview of positron annihilation spectroscopy for chemical analysis (PASCA). As an in situ technique PASCA is especially suitable for studying processes occurring at surfaces. The in situ characteristics of PASCA are treated. The principes of positron annihilation life time spectroscopy (PAL) are discussed and some important analytical applications such as, in determining of total surface areas and cavity volumes in chemical reactions, in the study of chemisorption and catalytic reactions on porous surfaces, in the analysis of bulk materials, in determining molecular association constants in biological systems, in proton and neutron activation analysis, in thin layer chromatography and in tracer technology. 28 refs.; 15 figs.; 8 tabs

  1. Development of optical techniques for chemical engineering applications

    Energy Technology Data Exchange (ETDEWEB)

    Lamadie, F.; Charton, S.; Langlard, M. de; Ouattara, M.; Sentis, M. [CEA, Centre de Marcoule, DEN,DTEC,SGCS, F-30207 Marcoule (France)

    2016-07-01

    The design of separation processes for nuclear spend fuel treatment, dedicated to either research studies or industrial applications, is currently based on a phenomenological approach, relying on Computational Fluid Dynamics, and complemented by validation tests performed at small-scale. Indeed, most of the steps of the Purex process involve multiphasic flows (dissolution, leaching, liquid-liquid extraction, precipitation, filtration, etc.). Therefore an accurate knowledge of the dispersed phase properties is required in order to assess their coupling with the flow features, to predict the process performance and efficiency and to achieve size reduction or extrapolation. Hence, the measurements of particulate flows properties, and especially the particles (or drops or bubbles) size distribution, concentration (i.e. hold-up) and velocity has become a growing issue. Relevant techniques for measuring these flow properties are multiple, from the high-speed video acquisition coupled to image processing to the laser-induced fluorescence, including the particle imaging velocimetry or interferometric techniques (digital in-line holography, rainbow refractometry, etc.). In this communication, different techniques developed at CEA Marcoule for the characterization of multiphase flows, will be introduced. The strong interaction with computational fluid dynamics, in the scope of a multi-scale approach, will be discussed through typical results of gas-liquid, liquid-liquid and solid-liquid flows possibly encountered in nuclear fuel reprocessing process. (authors)

  2. Gold analysis by the gamma absorption technique

    International Nuclear Information System (INIS)

    Kurtoglu, Arzu; Tugrul, A.B.

    2003-01-01

    Gold (Au) analyses are generally performed using destructive techniques. In this study, the Gamma Absorption Technique has been employed for gold analysis. A series of different gold alloys of known gold content were analysed and a calibration curve was obtained. This curve was then used for the analysis of unknown samples. Gold analyses can be made non-destructively, easily and quickly by the gamma absorption technique. The mass attenuation coefficients of the alloys were measured around the K-shell absorption edge of Au. Theoretical mass attenuation coefficient values were obtained using the WinXCom program and comparison of the experimental results with the theoretical values showed generally good and acceptable agreement

  3. Sensitivity analysis of hybrid thermoelastic techniques

    Science.gov (United States)

    W.A. Samad; J.M. Considine

    2017-01-01

    Stress functions have been used as a complementary tool to support experimental techniques, such as thermoelastic stress analysis (TSA) and digital image correlation (DIC), in an effort to evaluate the complete and separate full-field stresses of loaded structures. The need for such coupling between experimental data and stress functions is due to the fact that...

  4. Chemical analysis quality assurance at the ICPP

    International Nuclear Information System (INIS)

    Hand, R.L.

    1990-01-01

    This document discusses the chemical analysis quality assurance program at the ICPP which involves records management, analytical methods quality control, analysis procedures and training and qualification. Since 1979, the major portion of the quality assurance program has been implemented on a central analytical computer system. The individual features provided by the system are storage, retrieval, and search capabilities over all general request and sample analysis information, automatic method selection for all process streams, automation of all method calculations, automatic assignment of bias and precision estimates at all analysis levels, with-method-use requalification, untrained or unqualified analyst method lockout, statistical testing of all process stream results for replicate agreement, automatic testing of process results against pre- established operating, safety, or failure limits at varying confidence levels, and automatic transfer and report of all analysis data plus all statistical testing to the Production Department

  5. Microextraction sample preparation techniques in biomedical analysis.

    Science.gov (United States)

    Szultka, Malgorzata; Pomastowski, Pawel; Railean-Plugaru, Viorica; Buszewski, Boguslaw

    2014-11-01

    Biologically active compounds are found in biological samples at relatively low concentration levels. The sample preparation of target compounds from biological, pharmaceutical, environmental, and food matrices is one of the most time-consuming steps in the analytical procedure. The microextraction techniques are dominant. Metabolomic studies also require application of proper analytical technique for the determination of endogenic metabolites present in biological matrix on trace concentration levels. Due to the reproducibility of data, precision, relatively low cost of the appropriate analysis, simplicity of the determination, and the possibility of direct combination of those techniques with other methods (combination types on-line and off-line), they have become the most widespread in routine determinations. Additionally, sample pretreatment procedures have to be more selective, cheap, quick, and environmentally friendly. This review summarizes the current achievements and applications of microextraction techniques. The main aim is to deal with the utilization of different types of sorbents for microextraction and emphasize the use of new synthesized sorbents as well as to bring together studies concerning the systematic approach to method development. This review is dedicated to the description of microextraction techniques and their application in biomedical analysis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. CRDM motion analysis using machine learning technique

    International Nuclear Information System (INIS)

    Nishimura, Takuya; Nakayama, Hiroyuki; Saitoh, Mayumi; Yaguchi, Seiji

    2017-01-01

    Magnetic jack type Control Rod Drive Mechanism (CRDM) for pressurized water reactor (PWR) plant operates control rods in response to electrical signals from a reactor control system. CRDM operability is evaluated by quantifying armature's response of closed/opened time which means interval time between coil energizing/de-energizing points and armature closed/opened points. MHI has already developed an automatic CRDM motion analysis and applied it to actual plants so far. However, CRDM operational data has wide variation depending on their characteristics such as plant condition, plant, etc. In the existing motion analysis, there is an issue of analysis accuracy for applying a single analysis technique to all plant conditions, plants, etc. In this study, MHI investigated motion analysis using machine learning (Random Forests) which is flexibly accommodated to CRDM operational data with wide variation, and is improved analysis accuracy. (author)

  7. Review of analytical techniques to determine the chemical forms of vapours and aerosols released from overheated fuel

    International Nuclear Information System (INIS)

    Bowsher, B.R.; Nichols, A.L.

    1989-12-01

    A comprehensive review has been undertaken of appropriate analytical techniques to monitor and measure the chemical effects that occur in large-scale tests designed to study severe reactor accidents. Various methods have been developed to determine the chemical forms of the vapours, aerosols and deposits generated during and after such integral experiments. Other specific techniques have the long-term potential to provide some of the desired data in greater detail, although considerable efforts are still required to apply these techniques to the study of radioactive debris. Such in-situ and post-test methods of analysis have been also assessed in terms of their applicability to the analysis of samples from the Phebus-FP tests. The recommended in-situ methods of analysis are gamma-ray spectroscopy, potentiometry, mass spectrometry, and Raman/UV-visible absorption spectroscopy. Vapour/aerosol and deposition samples should also be obtained at well-defined time intervals during each experiment for subsequent post-test analysis. No single technique can provide all the necessary chemical data from these samples, and the most appropriate method of analysis involves a complementary combination of autoradiography, AES, IR, MRS, SEMS/EDS, SIMS/LMIS, XPS and XRD

  8. PHOTOGRAMMETRIC TECHNIQUES FOR ROAD SURFACE ANALYSIS

    Directory of Open Access Journals (Sweden)

    V. A. Knyaz

    2016-06-01

    Full Text Available The quality and condition of a road surface is of great importance for convenience and safety of driving. So the investigations of the behaviour of road materials in laboratory conditions and monitoring of existing roads are widely fulfilled for controlling a geometric parameters and detecting defects in the road surface. Photogrammetry as accurate non-contact measuring method provides powerful means for solving different tasks in road surface reconstruction and analysis. The range of dimensions concerned in road surface analysis can have great variation from tenths of millimetre to hundreds meters and more. So a set of techniques is needed to meet all requirements of road parameters estimation. Two photogrammetric techniques for road surface analysis are presented: for accurate measuring of road pavement and for road surface reconstruction based on imagery obtained from unmanned aerial vehicle. The first technique uses photogrammetric system based on structured light for fast and accurate surface 3D reconstruction and it allows analysing the characteristics of road texture and monitoring the pavement behaviour. The second technique provides dense 3D model road suitable for road macro parameters estimation.

  9. Comparison of chemical restraint techniques in ostrich (Struthio camelus

    Directory of Open Access Journals (Sweden)

    R Ciboto

    2006-06-01

    Full Text Available Chemical restraint in ostriches is usually required for short-time interventions. Thus, this study established and evaluated intravenous anesthetics formulated from commonly used drugs in order to accomplish total restraint on this species and allow painful procedures to be performed. Thirty male and female ostriches weighing from 40 to 90 kg were randomly distributed into five groups. Animals in Groups I, II and III were given acepromazine (0.25 mg/kg i.m. and those in Groups IV and V were given xylazine (1.0 mg/kg i.m.. The following drugs were administered intravenously 15 to 20 min later: Group I - propofol (4.0 mg/kg, Groups II and IV - ketamine (5.0 mg/kg and diazepam (0.25 mg/kg, Groups III and V - tiletamine-zolazepam (3.0 mg/kg. All protocols have produced satisfactory results regarding total containment, muscular relaxation and maintenance of the evaluated parameters within a normal range.

  10. Chemical reaction on solid surface observed through isotope tracer technique

    International Nuclear Information System (INIS)

    Tanaka, Ken-ichi

    1983-01-01

    In order to know the role of atoms and ions on solid surfaces as the partners participating in elementary processes, the literatures related to the isomerization and hydrogen exchanging reaction of olefines, the hydrogenation of olefines, the metathesis reaction and homologation of olefines based on solid catalysts were reviewed. Various olefines, of which the hydrogen atoms were substituted with deuterium at desired positions, were reacted using various solid catalysts such as ZnO, K 2 CO 3 on C, MoS 2 (single crystal and powder) and molybdenum oxide (with various carriers), and the infra-red spectra of adsorbed olefines on catalysts, the isotope composition of reaction products and the production rate of the reaction products were measured. From the results, the bonding mode of reactant with the atoms and ions on solid surfaces, and the mechanism of the elementary process were considered. The author emphasized that the mechanism of the chemical reaction on solid surfaces and the role of active points or catalysts can be made clear to the considerable extent by combining isotopes suitably. (Yoshitake, I.)

  11. Chemical reactions of fission products with ethylene using the gas jet technique

    International Nuclear Information System (INIS)

    Contis, E.T.; Rengan, Krish; Griffin, Henry C.

    1994-01-01

    An understanding of the nature of the chemical reactions taking place between fission products and their carrier gases, and the designing of a fast separation procedure were the purposes of this investigation. Chemical reactions of short-lived (less than one minute half-life) fission products with carrier gases lead to various chemical species which can be separated in the gas phase. The Gas Jet Facility at the Ford Nuclear Reactor was used to study the yields of volatile selenium and bromine fission products of 235 U using a semi-automatic batch solvent extraction technique. Heptane and water were used as organic and inorganic solvents. A carrier gas mixture of ethylene to pre-purified nitrogen (1 : 3) was used to sweep the fission products from the target to the chemistry area for analysis. The results indicated that the volatile selenium products generated by the interaction of selenium fission fragments with ethylene were predominantly organic in nature (84%), possibly organoselenides. The selenium values were used to resolve the fractions of the bromine nuclides, which come from two major sources, viz., directly from fission and from the beta-decay of selenium. The data showed that the fractions of independent bromine fission products in the organic phase were much lower compared to selenium; the bromine values range from 10 to 22% and varied with mass number. Results indicated that the bromine products were inorganic in nature, as possibly hydrogen chloride. ((orig.))

  12. Application of nonliner reduction techniques in chemical process modeling: a review

    International Nuclear Information System (INIS)

    Muhaimin, Z; Aziz, N.; Abd Shukor, S.R.

    2006-01-01

    Model reduction techniques have been used widely in engineering fields for electrical, mechanical as well as chemical engineering. The basic idea of reduction technique is to replace the original system by an approximating system with much smaller state-space dimension. A reduced order model is more beneficial to process and industrial field in terms of control purposes. This paper is to provide a review on application of nonlinear reduction techniques in chemical processes. The advantages and disadvantages of each technique reviewed are also highlighted

  13. From the coupling between ion beam analysis techniques and physico-chemical characterization methods to the study of irradiation effects on materials behaviour; Du couplage des techniques d'analyse par faisceaux d'ions et des methodes de caracterisation physico-chimique a l'etude des effets d'irradiation sur le comportement des materiaux

    Energy Technology Data Exchange (ETDEWEB)

    Millard-Pinard, N

    2003-07-01

    The general purpose of my research work is to follow and to interpret the surface evolution of materials, which have received several treatments. During my PhD and my post-doc work, my field of research was tribology. Since I arrived in the 'Aval du Cycle Electronucleaire' group of the Institut de Physique Nucleaire de Lyon, my research activities are in line with the CNRS program 'PACE ' (Programme sur l'Aval du Cycle Electronucleaire) within the ACTINET network. They are coordinated by the PARIS (Physico-chimie des actinides et autres radioelements en solution et aux interfaces) and NOMADE (NOuveaux MAteriaux pour les DEchets) GDR with ANDRA (Agence Nationale pour la gestion des Dechets RAdioactifs), EDF and IRSN (Institut de Radioprotection et de Surete Nucleaire) as partner organisations. My work focused on the study of fission products and actinides migration in barrier materials, which may be capable of assuring the long term safety of deep geological repositories. Until now, it was necessary to use the coupling of ion beam analysis techniques and physico-chemical characterization techniques. During the last few months, I have became interested in understanding radiolytic effects. This new orientation has led us to use ion beams as an irradiating tool. These irradiation experiments are pursued in three major projects. The study of cobalt sulfide inhibition effects of radiolysis gas production during the irradiation of model organic molecules. This is a collaboration with the IRSN, the Institut de Recherche sur la Catalyse and the Ecole Nationale Superieure des Mines de Saint-Etienne. A PhD, co-directed by M. Pijolat from ENSMSE and myself, concerning this study will start in October 2003. Water radiolysis effects on iron corrosion are also studied in the particular case of vitrified nuclear waste containers, which will be stored in deep geological repositories. One ANDRA financed PhD, co-directed by Nathalie Moncoffre and myself, is dedicated to this study

  14. From the coupling between ion beam analysis techniques and physico-chemical characterization methods to the study of irradiation effects on materials behaviour; Du couplage des techniques d'analyse par faisceaux d'ions et des methodes de caracterisation physico-chimique a l'etude des effets d'irradiation sur le comportement des materiaux

    Energy Technology Data Exchange (ETDEWEB)

    Millard-Pinard, N

    2003-07-01

    The general purpose of my research work is to follow and to interpret the surface evolution of materials, which have received several treatments. During my PhD and my post-doc work, my field of research was tribology. Since I arrived in the 'Aval du Cycle Electronucleaire' group of the Institut de Physique Nucleaire de Lyon, my research activities are in line with the CNRS program 'PACE ' (Programme sur l'Aval du Cycle Electronucleaire) within the ACTINET network. They are coordinated by the PARIS (Physico-chimie des actinides et autres radioelements en solution et aux interfaces) and NOMADE (NOuveaux MAteriaux pour les DEchets) GDR with ANDRA (Agence Nationale pour la gestion des Dechets RAdioactifs), EDF and IRSN (Institut de Radioprotection et de Surete Nucleaire) as partner organisations. My work focused on the study of fission products and actinides migration in barrier materials, which may be capable of assuring the long term safety of deep geological repositories. Until now, it was necessary to use the coupling of ion beam analysis techniques and physico-chemical characterization techniques. During the last few months, I have became interested in understanding radiolytic effects. This new orientation has led us to use ion beams as an irradiating tool. These irradiation experiments are pursued in three major projects. The study of cobalt sulfide inhibition effects of radiolysis gas production during the irradiation of model organic molecules. This is a collaboration with the IRSN, the Institut de Recherche sur la Catalyse and the Ecole Nationale Superieure des Mines de Saint-Etienne. A PhD, co-directed by M. Pijolat from ENSMSE and myself, concerning this study will start in October 2003. Water radiolysis effects on iron corrosion are also studied in the particular case of vitrified nuclear waste containers, which will be stored in deep geological repositories. One ANDRA financed PhD, co-directed by Nathalie Moncoffre and myself, is

  15. Diffraction analysis of customized illumination technique

    Science.gov (United States)

    Lim, Chang-Moon; Kim, Seo-Min; Eom, Tae-Seung; Moon, Seung Chan; Shin, Ki S.

    2004-05-01

    Various enhancement techniques such as alternating PSM, chrome-less phase lithography, double exposure, etc. have been considered as driving forces to lead the production k1 factor towards below 0.35. Among them, a layer specific optimization of illumination mode, so-called customized illumination technique receives deep attentions from lithographers recently. A new approach for illumination customization based on diffraction spectrum analysis is suggested in this paper. Illumination pupil is divided into various diffraction domains by comparing the similarity of the confined diffraction spectrum. Singular imaging property of individual diffraction domain makes it easier to build and understand the customized illumination shape. By comparing the goodness of image in each domain, it was possible to achieve the customized shape of illumination. With the help from this technique, it was found that the layout change would not gives the change in the shape of customized illumination mode.

  16. Fault tree analysis: concepts and techniques

    International Nuclear Information System (INIS)

    Fussell, J.B.

    1976-01-01

    Concepts and techniques of fault tree analysis have been developed over the past decade and now predictions from this type analysis are important considerations in the design of many systems such as aircraft, ships and their electronic systems, missiles, and nuclear reactor systems. Routine, hardware-oriented fault tree construction can be automated; however, considerable effort is needed in this area to get the methodology into production status. When this status is achieved, the entire analysis of hardware systems will be automated except for the system definition step. Automated analysis is not undesirable; to the contrary, when verified on adequately complex systems, automated analysis could well become a routine analysis. It could also provide an excellent start for a more in-depth fault tree analysis that includes environmental effects, common mode failure, and human errors. The automated analysis is extremely fast and frees the analyst from the routine hardware-oriented fault tree construction, as well as eliminates logic errors and errors of oversight in this part of the analysis. Automated analysis then affords the analyst a powerful tool to allow his prime efforts to be devoted to unearthing more subtle aspects of the modes of failure of the system

  17. Fast analysis of narcotic drugs by optical chemical imaging

    International Nuclear Information System (INIS)

    Fisher, Michal; Bulatov, Vallery; Schechter, Israel

    2003-01-01

    A new technique is proposed for fast detection, identification and imaging of narcotic drugs in their solid phase. This technique, which requires only a tiny sample of a few microns, is based on microscopic chemical imaging. Minor sample preparation is required, and results are obtained within seconds. As far as we know, this is the most sensitive detection system available today for solid drugs. The technique can be applied for fast analysis of minute drug residues, and therefore is of considerable importance for forensic applications. It is shown that identification of drug traces in realistic matrixes is possible. Two main methods were applied in this study for detection of drugs and drug derivatives. The first method was based on direct detection and chemical imaging of the auto-fluorescence of the analyzed drugs. This method is applicable when the analyzed drug emits fluorescence under the experiment conditions, such as lysergic acid diethylamide (known as LSD). The second method was used for obtaining chemical imaging of drugs that do not fluoresce under the experiment conditions. In these cases fluorescent labeling dyes were applied to the examined samples (including the drug and the matrix). Both methods are simple and rapid, and require minor or no sample preparation at all. Detection limits are very low in the picogram range

  18. Analytical techniques for wine analysis: An African perspective; a review

    International Nuclear Information System (INIS)

    Villiers, André de; Alberts, Phillipus; Tredoux, Andreas G.J.; Nieuwoudt, Hélène H.

    2012-01-01

    Highlights: ► Analytical techniques developed for grape and wine analysis in Africa are reviewed. ► The utility of infrared spectroscopic methods is demonstrated. ► An overview of separation of wine constituents by GC, HPLC, CE is presented. ► Novel LC and GC sample preparation methods for LC and GC are presented. ► Emerging methods for grape and wine analysis in Africa are discussed. - Abstract: Analytical chemistry is playing an ever-increasingly important role in the global wine industry. Chemical analysis of wine is essential in ensuring product safety and conformity to regulatory laws governing the international market, as well as understanding the fundamental aspects of grape and wine production to improve manufacturing processes. Within this field, advanced instrumental analysis methods have been exploited more extensively in recent years. Important advances in instrumental analytical techniques have also found application in the wine industry. This review aims to highlight the most important developments in the field of instrumental wine and grape analysis in the African context. The focus of this overview is specifically on the application of advanced instrumental techniques, including spectroscopic and chromatographic methods. Recent developments in wine and grape analysis and their application in the African context are highlighted, and future trends are discussed in terms of their potential contribution to the industry.

  19. Analytical techniques for wine analysis: An African perspective; a review

    Energy Technology Data Exchange (ETDEWEB)

    Villiers, Andre de, E-mail: ajdevill@sun.ac.za [Department of Chemistry and Polymer Science, Stellenbosch University, Private Bag X1, Matieland 7602, Stellenbosch (South Africa); Alberts, Phillipus [Department of Chemistry and Polymer Science, Stellenbosch University, Private Bag X1, Matieland 7602, Stellenbosch (South Africa); Tredoux, Andreas G.J.; Nieuwoudt, Helene H. [Institute for Wine Biotechnology, Department of Viticulture and Oenology, Stellenbosch University, Private Bag X1, Matieland 7602, Stellenbosch (South Africa)

    2012-06-12

    Highlights: Black-Right-Pointing-Pointer Analytical techniques developed for grape and wine analysis in Africa are reviewed. Black-Right-Pointing-Pointer The utility of infrared spectroscopic methods is demonstrated. Black-Right-Pointing-Pointer An overview of separation of wine constituents by GC, HPLC, CE is presented. Black-Right-Pointing-Pointer Novel LC and GC sample preparation methods for LC and GC are presented. Black-Right-Pointing-Pointer Emerging methods for grape and wine analysis in Africa are discussed. - Abstract: Analytical chemistry is playing an ever-increasingly important role in the global wine industry. Chemical analysis of wine is essential in ensuring product safety and conformity to regulatory laws governing the international market, as well as understanding the fundamental aspects of grape and wine production to improve manufacturing processes. Within this field, advanced instrumental analysis methods have been exploited more extensively in recent years. Important advances in instrumental analytical techniques have also found application in the wine industry. This review aims to highlight the most important developments in the field of instrumental wine and grape analysis in the African context. The focus of this overview is specifically on the application of advanced instrumental techniques, including spectroscopic and chromatographic methods. Recent developments in wine and grape analysis and their application in the African context are highlighted, and future trends are discussed in terms of their potential contribution to the industry.

  20. Chromatographic Techniques for Rare Earth Elements Analysis

    Science.gov (United States)

    Chen, Beibei; He, Man; Zhang, Huashan; Jiang, Zucheng; Hu, Bin

    2017-04-01

    The present capability of rare earth element (REE) analysis has been achieved by the development of two instrumental techniques. The efficiency of spectroscopic methods was extraordinarily improved for the detection and determination of REE traces in various materials. On the other hand, the determination of REEs very often depends on the preconcentration and separation of REEs, and chromatographic techniques are very powerful tools for the separation of REEs. By coupling with sensitive detectors, many ambitious analytical tasks can be fulfilled. Liquid chromatography is the most widely used technique. Different combinations of stationary phases and mobile phases could be used in ion exchange chromatography, ion chromatography, ion-pair reverse-phase chromatography and some other techniques. The application of gas chromatography is limited because only volatile compounds of REEs can be separated. Thin-layer and paper chromatography are techniques that cannot be directly coupled with suitable detectors, which limit their applications. For special demands, separations can be performed by capillary electrophoresis, which has very high separation efficiency.

  1. Swept frequency acoustic interferometry technique for chemical weapons verification and monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, D.N.; Anthony, B.W.; Lizon, D.C.

    1995-03-01

    Nondestructive evaluation (NDE) techniques are important for rapid on-site verification and monitoring of chemical munitions, such as artillery shells and bulk containers. Present NDE techniques provide only limited characterizations of such munitions. This paper describes the development of a novel noninvasive technique, swept-frequency acoustic interferometry (SFAI), that significantly enhances the capability of munitions characterizations. The SFAI technique allows very accurate and simultaneous determination of sound velocity and attenuation of chemical agents over a large frequency range inside artillery shells, in addition to determining agent density. The frequency-dependent sound velocity and attenuation can, in principle, provide molecular relaxation properties of the chemical agent. The same instrument also enables a direct fill-level measurement in bulk containers. Industrial and other applications of this general-purpose technique are also discussed.

  2. Artificial Intelligence techniques for big data analysis

    OpenAIRE

    Aditya Khatri

    2017-01-01

    During my stay in Salamanca (Spain), I was fortunate enough to participate in the BISITE Research Group of the University of Salamanca. The University of Salamanca is the oldest university in Spain and in 2018 it celebrates its 8th centenary. As a computer science researcher, I participated in one of the many international projects that the research group has active, especially in big data analysis using Artificial Intelligence (AI) techniques. AI is one of BISITE's main lines of rese...

  3. Applications Of Binary Image Analysis Techniques

    Science.gov (United States)

    Tropf, H.; Enderle, E.; Kammerer, H. P.

    1983-10-01

    After discussing the conditions where binary image analysis techniques can be used, three new applications of the fast binary image analysis system S.A.M. (Sensorsystem for Automation and Measurement) are reported: (1) The human view direction is measured at TV frame rate while the subject's head is free movable. (2) Industrial parts hanging on a moving conveyor are classified prior to spray painting by robot. (3) In automotive wheel assembly, the eccentricity of the wheel is minimized by turning the tyre relative to the rim in order to balance the eccentricity of the components.

  4. Infusing Reliability Techniques into Software Safety Analysis

    Science.gov (United States)

    Shi, Ying

    2015-01-01

    Software safety analysis for a large software intensive system is always a challenge. Software safety practitioners need to ensure that software related hazards are completely identified, controlled, and tracked. This paper discusses in detail how to incorporate the traditional reliability techniques into the entire software safety analysis process. In addition, this paper addresses how information can be effectively shared between the various practitioners involved in the software safety analyses. The author has successfully applied the approach to several aerospace applications. Examples are provided to illustrate the key steps of the proposed approach.

  5. A cell-microelectronic sensing technique for profiling cytotoxicity of chemicals

    International Nuclear Information System (INIS)

    Boyd, Jessica M.; Huang, Li; Xie Li; Moe, Birget; Gabos, Stephan; Li Xingfang

    2008-01-01

    A cell-microelectronic sensing technique is developed for profiling chemical cytotoxicity and is used to study different cytotoxic effects of the same class chemicals using nitrosamines as examples. This technique uses three human cell lines (T24 bladder, HepG2 liver, and A549 lung carcinoma cells) and Chinese hamster ovary (CHO-K1) cells in parallel as the living components of the sensors of a real-time cell electronic sensing (RT-CES) method for dynamic monitoring of chemical toxicity. The RT-CES technique measures changes in the impedance of individual microelectronic wells that is correlated linearly with changes in cell numbers during t log phase of cell growth, thus allowing determination of cytotoxicity. Four nitrosamines, N-nitrosodimethylamine (NDMA), N-nitrosodiphenylamine (NDPhA), N-nitrosopiperidine (NPip), and N-nitrosopyrrolidine (NPyr), were examined and unique cytotoxicity profiles were detected for each nitrosamine. In vitro cytotoxicity values (IC 50 ) for NDPhA (ranging from 0.6 to 1.9 mM) were significantly lower than the IC 50 values for the well-known carcinogen NDMA (15-95 mM) in all four cell lines. T24 cells were the most sensitive to nitrosamine exposure among the four cell lines tested (T24 > CHO > A549 > HepG2), suggesting that T24 may serve as a new sensitive model for cytotoxicity screening. Cell staining results confirmed that administration of the IC 50 concentration from the RT-CES experiments inhibited cell growth by 50% compared to the controls, indicating that the RT-CES method provides reliable measures of IC 50 . Staining and cell-cycle analysis confirmed that NDPhA caused cell-cycle arrest at the G0/G1 phase, whereas NDMA did not disrupt the cell cycle but induced cell death, thus explaining the different cytotoxicity profiles detected by the RT-CES method. The parallel cytotoxicity profiling of nitrosamines on the four cell lines by the RT-CES method led to the discovery of the unique cytotoxicity of NDPhA causing cell

  6. A cell-microelectronic sensing technique for profiling cytotoxicity of chemicals

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Jessica M [Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, 10-102 Clinical Sciences Building, Edmonton, Alberta, T6G 2G3 (Canada); Huang, Li [Environmental Health Sciences, Department of Public Health Sciences, School of Public Health, University of Alberta, 10-102 Clinical Sciences Building, Edmonton, Alberta, T6G 2G3 (Canada); Li, Xie; Moe, Birget [Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, 10-102 Clinical Sciences Building, Edmonton, Alberta, T6G 2G3 (Canada); Gabos, Stephan [Public Health Surveillance and Environmental Health, Alberta Health and Wellness, 10025 Jasper Avenue, Box 1360, Edmonton, Alberta, T5J 2N3 (Canada); Xingfang, Li [Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, 10-102 Clinical Sciences Building, Edmonton, Alberta, T6G 2G3 (Canada); Environmental Health Sciences, Department of Public Health Sciences, School of Public Health, University of Alberta, 10-102 Clinical Sciences Building, Edmonton, Alberta, T6G 2G3 (Canada)], E-mail: xingfang.li@ualberta.ca

    2008-05-12

    A cell-microelectronic sensing technique is developed for profiling chemical cytotoxicity and is used to study different cytotoxic effects of the same class chemicals using nitrosamines as examples. This technique uses three human cell lines (T24 bladder, HepG2 liver, and A549 lung carcinoma cells) and Chinese hamster ovary (CHO-K1) cells in parallel as the living components of the sensors of a real-time cell electronic sensing (RT-CES) method for dynamic monitoring of chemical toxicity. The RT-CES technique measures changes in the impedance of individual microelectronic wells that is correlated linearly with changes in cell numbers during t log phase of cell growth, thus allowing determination of cytotoxicity. Four nitrosamines, N-nitrosodimethylamine (NDMA), N-nitrosodiphenylamine (NDPhA), N-nitrosopiperidine (NPip), and N-nitrosopyrrolidine (NPyr), were examined and unique cytotoxicity profiles were detected for each nitrosamine. In vitro cytotoxicity values (IC{sub 50}) for NDPhA (ranging from 0.6 to 1.9 mM) were significantly lower than the IC{sub 50} values for the well-known carcinogen NDMA (15-95 mM) in all four cell lines. T24 cells were the most sensitive to nitrosamine exposure among the four cell lines tested (T24 > CHO > A549 > HepG2), suggesting that T24 may serve as a new sensitive model for cytotoxicity screening. Cell staining results confirmed that administration of the IC{sub 50} concentration from the RT-CES experiments inhibited cell growth by 50% compared to the controls, indicating that the RT-CES method provides reliable measures of IC{sub 50}. Staining and cell-cycle analysis confirmed that NDPhA caused cell-cycle arrest at the G0/G1 phase, whereas NDMA did not disrupt the cell cycle but induced cell death, thus explaining the different cytotoxicity profiles detected by the RT-CES method. The parallel cytotoxicity profiling of nitrosamines on the four cell lines by the RT-CES method led to the discovery of the unique cytotoxicity of NDPh

  7. The development of human behavior analysis techniques

    International Nuclear Information System (INIS)

    Lee, Jung Woon; Lee, Yong Hee; Park, Geun Ok; Cheon, Se Woo; Suh, Sang Moon; Oh, In Suk; Lee, Hyun Chul; Park, Jae Chang.

    1997-07-01

    In this project, which is to study on man-machine interaction in Korean nuclear power plants, we developed SACOM (Simulation Analyzer with a Cognitive Operator Model), a tool for the assessment of task performance in the control rooms using software simulation, and also develop human error analysis and application techniques. SACOM was developed to assess operator's physical workload, workload in information navigation at VDU workstations, and cognitive workload in procedural tasks. We developed trip analysis system including a procedure based on man-machine interaction analysis system including a procedure based on man-machine interaction analysis and a classification system. We analyzed a total of 277 trips occurred from 1978 to 1994 to produce trip summary information, and for 79 cases induced by human errors time-lined man-machine interactions. The INSTEC, a database system of our analysis results, was developed. The MARSTEC, a multimedia authoring and representation system for trip information, was also developed, and techniques for human error detection in human factors experiments were established. (author). 121 refs., 38 tabs., 52 figs

  8. The development of human behavior analysis techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Woon; Lee, Yong Hee; Park, Geun Ok; Cheon, Se Woo; Suh, Sang Moon; Oh, In Suk; Lee, Hyun Chul; Park, Jae Chang

    1997-07-01

    In this project, which is to study on man-machine interaction in Korean nuclear power plants, we developed SACOM (Simulation Analyzer with a Cognitive Operator Model), a tool for the assessment of task performance in the control rooms using software simulation, and also develop human error analysis and application techniques. SACOM was developed to assess operator`s physical workload, workload in information navigation at VDU workstations, and cognitive workload in procedural tasks. We developed trip analysis system including a procedure based on man-machine interaction analysis system including a procedure based on man-machine interaction analysis and a classification system. We analyzed a total of 277 trips occurred from 1978 to 1994 to produce trip summary information, and for 79 cases induced by human errors time-lined man-machine interactions. The INSTEC, a database system of our analysis results, was developed. The MARSTEC, a multimedia authoring and representation system for trip information, was also developed, and techniques for human error detection in human factors experiments were established. (author). 121 refs., 38 tabs., 52 figs.

  9. Multivariate analysis of remote LIBS spectra using partial least squares, principal component analysis, and related techniques

    Energy Technology Data Exchange (ETDEWEB)

    Clegg, Samuel M [Los Alamos National Laboratory; Barefield, James E [Los Alamos National Laboratory; Wiens, Roger C [Los Alamos National Laboratory; Sklute, Elizabeth [MT HOLYOKE COLLEGE; Dyare, Melinda D [MT HOLYOKE COLLEGE

    2008-01-01

    Quantitative analysis with LIBS traditionally employs calibration curves that are complicated by the chemical matrix effects. These chemical matrix effects influence the LIBS plasma and the ratio of elemental composition to elemental emission line intensity. Consequently, LIBS calibration typically requires a priori knowledge of the unknown, in order for a series of calibration standards similar to the unknown to be employed. In this paper, three new Multivariate Analysis (MV A) techniques are employed to analyze the LIBS spectra of 18 disparate igneous and highly-metamorphosed rock samples. Partial Least Squares (PLS) analysis is used to generate a calibration model from which unknown samples can be analyzed. Principal Components Analysis (PCA) and Soft Independent Modeling of Class Analogy (SIMCA) are employed to generate a model and predict the rock type of the samples. These MV A techniques appear to exploit the matrix effects associated with the chemistries of these 18 samples.

  10. Application and further development of diffusion based 2D chemical imaging techniques in the rhizosphere

    Science.gov (United States)

    Hoefer, Christoph; Santner, Jakob; Borisov, Sergey; Kreuzeder, Andreas; Wenzel, Walter; Puschenreiter, Markus

    2015-04-01

    Two dimensional chemical imaging of root processes refers to novel in situ methods to investigate and map solutes at a high spatial resolution (sub-mm). The visualization of these solutes reveals new insights in soil biogeochemistry and root processes. We derive chemical images by using data from DGT-LA-ICP-MS (Diffusive Gradients in Thin Films and Laser Ablation Inductively Coupled Plasma Mass Spectrometry) and POS (Planar Optode Sensors). Both technologies have shown promising results when applied in aqueous environment but need to be refined and improved for imaging at the soil-plant interface. Co-localized mapping using combined DGT and POS technologies and the development of new gel combinations are in our focus. DGTs are smart and thin (hydrogels; containing a binding resin for the targeted analytes (e.g. trace metals, phosphate, sulphide or radionuclides). The measurement principle is passive and diffusion based. The present analytes are diffusing into the gel and are bound by the resin. Thereby, the resin acts as zero sink. After application, DGTs are retrieved, dried, and analysed using LA-ICP-MS. The data is then normalized by an internal standard (e.g. 13C), calibrated using in-house standards and chemical images of the target area are plotted using imaging software. POS are, similar to DGT, thin sensor foils containing a fluorophore coating depending on the target analyte. The measurement principle is based on excitation of the flourophore by a specific wavelength and emission of the fluorophore depending on the presence of the analyte. The emitted signal is captured using optical filters and a DSLR camera. While DGT analysis is destructive, POS measurements can be performed continuously during the application. Both semi-quantitative techniques allow an in situ application to visualize chemical processes directly at the soil-plant interface. Here, we present a summary of results from rhizotron experiments with different plants in metal contaminated and

  11. Development of chemical equilibrium analysis code 'CHEEQ'

    International Nuclear Information System (INIS)

    Nagai, Shuichiro

    2006-08-01

    'CHEEQ' code which calculates the partial pressure and the mass of the system consisting of ideal gas and pure condensed phase compounds, was developed. Characteristics of 'CHEEQ' code are as follows. All the chemical equilibrium equations were described by the formation reactions from the mono-atomic gases in order to simplify the code structure and input preparation. Chemical equilibrium conditions, Σν i μ i =0 for the gaseous compounds and precipitated condensed phase compounds and Σν i μ i > 0 for the non-precipitated condensed phase compounds, were applied. Where, ν i and μ i are stoichiometric coefficient and chemical potential of component i. Virtual solid model was introduced to perform the calculation of constant partial pressure condition. 'CHEEQ' was consisted of following 3 parts, (1) analysis code, zc132. f. (2) thermodynamic data base, zmdb01 and (3) input data file, zindb. 'CHEEQ' code can calculate the system which consisted of elements (max.20), condensed phase compounds (max.100) and gaseous compounds. (max.200). Thermodynamic data base, zmdb01 contains about 1000 elements and compounds, and 200 of them were Actinide elements and their compounds. This report describes the basic equations, the outline of the solution procedure and instructions to prepare the input data and to evaluate the calculation results. (author)

  12. VALIDATION GUIDELINES FOR LABORATORIES PERFORMING FORENSIC ANALYSIS OF CHEMICAL TERRORISM

    Science.gov (United States)

    The Scientific Working Group on Forensic Analysis of Chemical Terrorism (SWGFACT) has developed the following guidelines for laboratories engaged in the forensic analysis of chemical evidence associated with terrorism. This document provides a baseline framework and guidance for...

  13. A new analysis technique for microsamples

    International Nuclear Information System (INIS)

    Boyer, R.; Journoux, J.P.; Duval, C.

    1989-01-01

    For many decades, isotopic analysis of Uranium or Plutonium has been performed by mass spectrometry. The most recent analytical techniques, using the counting method or a plasma torch combined with a mass spectrometer (ICP.MS) have not yet to reach a greater degree of precision than the older methods in this field. The two means of ionization for isotopic analysis - by electronic bombardment of atoms or molecules (source of gas ions) and - by thermal effect (thermoionic source) are compared revealing some inconsistency between the quantity of sample necessary for analysis and the luminosity. In fact, the quantity of sample necessary for the gas source mass spectrometer is 10 to 20 times greater than that for the thermoionization spectrometer, while the sample consumption is between 10 5 to 10 6 times greater. This proves that almost the entire sample is not necessary for the measurement; it is only required because of the system of introduction for the gas spectrometer. The new analysis technique referred to as ''Microfluorination'' corrects this anomaly and exploits the advantages of the electron bombardment method of ionization

  14. Flash Infrared Thermography Contrast Data Analysis Technique

    Science.gov (United States)

    Koshti, Ajay

    2014-01-01

    This paper provides information on an IR Contrast technique that involves extracting normalized contrast versus time evolutions from the flash thermography inspection infrared video data. The analysis calculates thermal measurement features from the contrast evolution. In addition, simulation of the contrast evolution is achieved through calibration on measured contrast evolutions from many flat-bottom holes in the subject material. The measurement features and the contrast simulation are used to evaluate flash thermography data in order to characterize delamination-like anomalies. The thermal measurement features relate to the anomaly characteristics. The contrast evolution simulation is matched to the measured contrast evolution over an anomaly to provide an assessment of the anomaly depth and width which correspond to the depth and diameter of the equivalent flat-bottom hole (EFBH) similar to that used as input to the simulation. A similar analysis, in terms of diameter and depth of an equivalent uniform gap (EUG) providing a best match with the measured contrast evolution, is also provided. An edge detection technique called the half-max is used to measure width and length of the anomaly. Results of the half-max width and the EFBH/EUG diameter are compared to evaluate the anomaly. The information provided here is geared towards explaining the IR Contrast technique. Results from a limited amount of validation data on reinforced carbon-carbon (RCC) hardware are included in this paper.

  15. Chemical composition analysis and authentication of whisky.

    Science.gov (United States)

    Wiśniewska, Paulina; Dymerski, Tomasz; Wardencki, Waldemar; Namieśnik, Jacek

    2015-08-30

    Whisky (whiskey) is one of the most popular spirit-based drinks made from malted or saccharified grains, which should mature for at least 3 years in wooden barrels. High popularity of products usually causes a potential risk of adulteration. Thus authenticity assessment is one of the key elements of food product marketing. Authentication of whisky is based on comparing the composition of this alcohol with other spirit drinks. The present review summarizes all information about the comparison of whisky and other alcoholic beverages, the identification of type of whisky or the assessment of its quality and finally the authentication of whisky. The article also presents the various techniques used for analyzing whisky, such as gas and liquid chromatography with different types of detectors (FID, AED, UV-Vis), electronic nose, atomic absorption spectroscopy and mass spectrometry. In some cases the application of chemometric methods is also described, namely PCA, DFA, LDA, ANOVA, SIMCA, PNN, k-NN and CA, as well as preparation techniques such SPME or SPE. © 2014 Society of Chemical Industry.

  16. Spectroscopic analysis technique for arc-welding process control

    Science.gov (United States)

    Mirapeix, Jesús; Cobo, Adolfo; Conde, Olga; Quintela, María Ángeles; López-Higuera, José-Miguel

    2005-09-01

    The spectroscopic analysis of the light emitted by thermal plasmas has found many applications, from chemical analysis to monitoring and control of industrial processes. Particularly, it has been demonstrated that the analysis of the thermal plasma generated during arc or laser welding can supply information about the process and, thus, about the quality of the weld. In some critical applications (e.g. the aerospace sector), an early, real-time detection of defects in the weld seam (oxidation, porosity, lack of penetration, ...) is highly desirable as it can reduce expensive non-destructive testing (NDT). Among others techniques, full spectroscopic analysis of the plasma emission is known to offer rich information about the process itself, but it is also very demanding in terms of real-time implementations. In this paper, we proposed a technique for the analysis of the plasma emission spectrum that is able to detect, in real-time, changes in the process parameters that could lead to the formation of defects in the weld seam. It is based on the estimation of the electronic temperature of the plasma through the analysis of the emission peaks from multiple atomic species. Unlike traditional techniques, which usually involve peak fitting to Voigt functions using the Levenberg-Marquardt recursive method, we employ the LPO (Linear Phase Operator) sub-pixel algorithm to accurately estimate the central wavelength of the peaks (allowing an automatic identification of each atomic species) and cubic-spline interpolation of the noisy data to obtain the intensity and width of the peaks. Experimental tests on TIG-welding using fiber-optic capture of light and a low-cost CCD-based spectrometer, show that some typical defects can be easily detected and identified with this technique, whose typical processing time for multiple peak analysis is less than 20msec. running in a conventional PC.

  17. Tissue chemical analysis with muonic X-rays

    International Nuclear Information System (INIS)

    Hutson, R.L.; Reidy, J.J.; Springer, K.; Daniel, H.; Knowles, H.B.

    1976-01-01

    The stopped muon channel at the Clinton P. Anderson Meson Physics Facility (LAMPF) was used as a source of muons for studying the elemental composition of tissue with muonic X rays. The X ray spectra from several types of tissue were used to determine the amounts of carbon, nitrogen, and oxygen present. These determinations agree with the results of more conventional chemical analysis. The results show that muonic X rays offer a non-invasive technique for determining the amounts of the more abundant elements present in selected regions of the body. (orig.) [de

  18. Dry-plasma-free chemical etch technique for variability reduction in multi-patterning (Conference Presentation)

    Science.gov (United States)

    Kal, Subhadeep; Mohanty, Nihar; Farrell, Richard A.; Franke, Elliott; Raley, Angelique; Thibaut, Sophie; Pereira, Cheryl; Pillai, Karthik; Ko, Akiteru; Mosden, Aelan; Biolsi, Peter

    2017-04-01

    Scaling beyond the 7nm technology node demands significant control over the variability down to a few angstroms, in order to achieve reasonable yield. For example, to meet the current scaling targets it is highly desirable to achieve sub 30nm pitch line/space features at back-end of the line (BEOL) or front end of line (FEOL); uniform and precise contact/hole patterning at middle of line (MOL). One of the quintessential requirements for such precise and possibly self-aligned patterning strategies is superior etch selectivity between the target films while other masks/films are exposed. The need to achieve high etch selectivity becomes more evident for unit process development at MOL and BEOL, as a result of low density films choices (compared to FEOL film choices) due to lower temperature budget. Low etch selectivity with conventional plasma and wet chemical etch techniques, causes significant gouging (un-intended etching of etch stop layer, as shown in Fig 1), high line edge roughness (LER)/line width roughness (LWR), non-uniformity, etc. In certain circumstances this may lead to added downstream process stochastics. Furthermore, conventional plasma etches may also have the added disadvantage of plasma VUV damage and corner rounding (Fig. 1). Finally, the above mentioned factors can potentially compromise edge placement error (EPE) and/or yield. Therefore a process flow enabled with extremely high selective etches inherent to film properties and/or etch chemistries is a significant advantage. To improve this etch selectivity for certain etch steps during a process flow, we have to implement alternate highly selective, plasma free techniques in conjunction with conventional plasma etches (Fig 2.). In this article, we will present our plasma free, chemical gas phase etch technique using chemistries that have high selectivity towards a spectrum of films owing to the reaction mechanism ( as shown Fig 1). Gas phase etches also help eliminate plasma damage to the

  19. Airborne chemistry: acoustic levitation in chemical analysis.

    Science.gov (United States)

    Santesson, Sabina; Nilsson, Staffan

    2004-04-01

    This review with 60 references describes a unique path to miniaturisation, that is, the use of acoustic levitation in analytical and bioanalytical chemistry applications. Levitation of small volumes of sample by means of a levitation technique can be used as a way to avoid solid walls around the sample, thus circumventing the main problem of miniaturisation, the unfavourable surface-to-volume ratio. Different techniques for sample levitation have been developed and improved. Of the levitation techniques described, acoustic or ultrasonic levitation fulfils all requirements for analytical chemistry applications. This technique has previously been used to study properties of molten materials and the equilibrium shape()and stability of liquid drops. Temperature and mass transfer in levitated drops have also been described, as have crystallisation and microgravity applications. The airborne analytical system described here is equipped with different and exchangeable remote detection systems. The levitated drops are normally in the 100 nL-2 microL volume range and additions to the levitated drop can be made in the pL-volume range. The use of levitated drops in analytical and bioanalytical chemistry offers several benefits. Several remote detection systems are compatible with acoustic levitation, including fluorescence imaging detection, right angle light scattering, Raman spectroscopy, and X-ray diffraction. Applications include liquid/liquid extractions, solvent exchange, analyte enrichment, single-cell analysis, cell-cell communication studies, precipitation screening of proteins to establish nucleation conditions, and crystallisation of proteins and pharmaceuticals.

  20. Reliability analysis techniques for the design engineer

    International Nuclear Information System (INIS)

    Corran, E.R.; Witt, H.H.

    1982-01-01

    This paper describes a fault tree analysis package that eliminates most of the housekeeping tasks involved in proceeding from the initial construction of a fault tree to the final stage of presenting a reliability analysis in a safety report. It is suitable for designers with relatively little training in reliability analysis and computer operation. Users can rapidly investigate the reliability implications of various options at the design stage and evolve a system which meets specified reliability objectives. Later independent review is thus unlikely to reveal major shortcomings necessitating modification and project delays. The package operates interactively, allowing the user to concentrate on the creative task of developing the system fault tree, which may be modified and displayed graphically. For preliminary analysis, system data can be derived automatically from a generic data bank. As the analysis proceeds, improved estimates of critical failure rates and test and maintenance schedules can be inserted. The technique is applied to the reliability analysis of the recently upgraded HIFAR Containment Isolation System. (author)

  1. Medium scale test study of chemical cleaning technique for secondary side of SG in PWR

    International Nuclear Information System (INIS)

    Zhang Mengqin; Zhang Shufeng; Yu Jinghua; Hou Shufeng

    1997-08-01

    The medium scale test study of chemical cleaning technique for removing corrosion product (Fe 3 O 4 ) in secondary side of SG in PWR has been completed. The test has been carried out in a medium scale test loop. The medium scale test evaluated the effect of the chemical cleaning technique (temperature, flow rate, cleaning time, cleaning process), the state of corrosion product deposition on magnetite (Fe 3 O 4 ) solubility and safety of materials of SG in cleaning process. The inhibitor component of chemical cleaning agent has been improved by electrochemical linear polarization method, the effect of inhibitor on corrosion resistance of materials have been examined in the medium scale test loop, the most components of chemical cleaning agent have been obtained, the EDTA is main component in cleaning agent. The electrochemical method for monitor corrosion of materials during cleaning process has been completed in the laboratory. The study of the medium scale test of chemical cleaning technique have had the optimum chemical cleaning technique for remove corrosion product in SG secondary side of PWR. (9 refs., 4 figs., 11 tabs.)

  2. Interferogram analysis using the Abel inversion technique

    International Nuclear Information System (INIS)

    Yusof Munajat; Mohamad Kadim Suaidi

    2000-01-01

    High speed and high resolution optical detection system were used to capture the image of acoustic waves propagation. The freeze image in the form of interferogram was analysed to calculate the transient pressure profile of the acoustic waves. The interferogram analysis was based on the fringe shift and the application of the Abel inversion technique. An easier approach was made by mean of using MathCAD program as a tool in the programming; yet powerful enough to make such calculation, plotting and transfer of file. (Author)

  3. Systems analysis of past, present, and future chemical terrorism scenarios.

    Energy Technology Data Exchange (ETDEWEB)

    Hoette, Trisha Marie

    2012-03-01

    Throughout history, as new chemical threats arose, strategies for the defense against chemical attacks have also evolved. As a part of an Early Career Laboratory Directed Research and Development project, a systems analysis of past, present, and future chemical terrorism scenarios was performed to understand how the chemical threats and attack strategies change over time. For the analysis, the difficulty in executing chemical attack was evaluated within a framework of three major scenario elements. First, historical examples of chemical terrorism were examined to determine how the use of chemical threats, versus other weapons, contributed to the successful execution of the attack. Using the same framework, the future of chemical terrorism was assessed with respect to the impact of globalization and new technologies. Finally, the efficacy of the current defenses against contemporary chemical terrorism was considered briefly. The results of this analysis justify the need for continued diligence in chemical defense.

  4. Early detection and identification of anomalies in chemical regime based on computational intelligence techniques

    International Nuclear Information System (INIS)

    Figedy, Stefan; Smiesko, Ivan

    2012-01-01

    This article provides brief information about the fundamental features of a newly-developed diagnostic system for early detection and identification of anomalies being generated in water chemistry regime of the primary and secondary circuit of the VVER-440 reactor. This system, which is called SACHER (System of Analysis of CHEmical Regime), was installed within the major modernization project at the NPP-V2 Bohunice in the Slovak Republic. The SACHER system has been fully developed on MATLAB environment. It is based on computational intelligence techniques and inserts various elements of intelligent data processing modules for clustering, diagnosing, future prediction, signal validation, etc, into the overall chemical information system. The application of SACHER would essentially assist chemists to identify the current situation regarding anomalies being generated in the primary and secondary circuit water chemistry. This system is to be used for diagnostics and data handling, however it is not intended to fully replace the presence of experienced chemists to decide upon corrective actions. (author)

  5. Low energy analysis techniques for CUORE

    Energy Technology Data Exchange (ETDEWEB)

    Alduino, C.; Avignone, F.T.; Chott, N.; Creswick, R.J.; Rosenfeld, C.; Wilson, J. [University of South Carolina, Department of Physics and Astronomy, Columbia, SC (United States); Alfonso, K.; Huang, H.Z.; Sakai, M.; Schmidt, J. [University of California, Department of Physics and Astronomy, Los Angeles, CA (United States); Artusa, D.R.; Rusconi, C. [University of South Carolina, Department of Physics and Astronomy, Columbia, SC (United States); INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); Azzolini, O.; Camacho, A.; Keppel, G.; Palmieri, V.; Pira, C. [INFN-Laboratori Nazionali di Legnaro, Padua (Italy); Bari, G.; Deninno, M.M. [INFN-Sezione di Bologna, Bologna (Italy); Beeman, J.W. [Lawrence Berkeley National Laboratory, Materials Science Division, Berkeley, CA (United States); Bellini, F.; Cosmelli, C.; Ferroni, F.; Piperno, G. [Sapienza Universita di Roma, Dipartimento di Fisica, Rome (Italy); INFN-Sezione di Roma, Rome (Italy); Benato, G.; Singh, V. [University of California, Department of Physics, Berkeley, CA (United States); Bersani, A.; Caminata, A. [INFN-Sezione di Genova, Genoa (Italy); Biassoni, M.; Brofferio, C.; Capelli, S.; Carniti, P.; Cassina, L.; Chiesa, D.; Clemenza, M.; Faverzani, M.; Fiorini, E.; Gironi, L.; Gotti, C.; Maino, M.; Nastasi, M.; Nucciotti, A.; Pavan, M.; Pozzi, S.; Sisti, M.; Terranova, F.; Zanotti, L. [Universita di Milano-Bicocca, Dipartimento di Fisica, Milan (Italy); INFN-Sezione di Milano Bicocca, Milan (Italy); Branca, A.; Taffarello, L. [INFN-Sezione di Padova, Padua (Italy); Bucci, C.; Cappelli, L.; D' Addabbo, A.; Gorla, P.; Pattavina, L.; Pirro, S. [INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); Canonica, L. [INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); Massachusetts Institute of Technology, Cambridge, MA (United States); Cao, X.G.; Fang, D.Q.; Ma, Y.G.; Wang, H.W.; Zhang, G.Q. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai (China); Cardani, L.; Casali, N.; Dafinei, I.; Morganti, S.; Mosteiro, P.J.; Tomei, C.; Vignati, M. [INFN-Sezione di Roma, Rome (Italy); Copello, S.; Di Domizio, S.; Marini, L.; Pallavicini, M. [INFN-Sezione di Genova, Genoa (Italy); Universita di Genova, Dipartimento di Fisica, Genoa (Italy); Cremonesi, O.; Ferri, E.; Giachero, A.; Pessina, G.; Previtali, E. [INFN-Sezione di Milano Bicocca, Milan (Italy); Cushman, J.S.; Davis, C.J.; Heeger, K.M.; Lim, K.E.; Maruyama, R.H. [Yale University, Department of Physics, New Haven, CT (United States); D' Aguanno, D.; Pagliarone, C.E. [INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); Universita degli Studi di Cassino e del Lazio Meridionale, Dipartimento di Ingegneria Civile e Meccanica, Cassino (Italy); Dell' Oro, S. [INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); INFN-Gran Sasso Science Institute, L' Aquila (Italy); Di Vacri, M.L.; Santone, D. [INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); Universita dell' Aquila, Dipartimento di Scienze Fisiche e Chimiche, L' Aquila (Italy); Drobizhev, A.; Hennings-Yeomans, R.; Kolomensky, Yu.G.; Wagaarachchi, S.L. [University of California, Department of Physics, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Franceschi, M.A.; Ligi, C.; Napolitano, T. [INFN-Laboratori Nazionali di Frascati, Rome (Italy); Freedman, S.J. [University of California, Department of Physics, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Fujikawa, B.K.; Mei, Y.; Schmidt, B.; Smith, A.R.; Welliver, B. [Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Giuliani, A.; Novati, V. [Universite Paris-Saclay, CSNSM, Univ. Paris-Sud, CNRS/IN2P3, Orsay (France); Gladstone, L.; Leder, A.; Ouellet, J.L.; Winslow, L.A. [Massachusetts Institute of Technology, Cambridge, MA (United States); Gutierrez, T.D. [California Polytechnic State University, Physics Department, San Luis Obispo, CA (United States); Haller, E.E. [Lawrence Berkeley National Laboratory, Materials Science Division, Berkeley, CA (United States); University of California, Department of Materials Science and Engineering, Berkeley, CA (United States); Han, K. [Shanghai Jiao Tong University, Department of Physics and Astronomy, Shanghai (China); Hansen, E. [University of California, Department of Physics and Astronomy, Los Angeles, CA (United States); Massachusetts Institute of Technology, Cambridge, MA (United States); Kadel, R. [Lawrence Berkeley National Laboratory, Physics Division, Berkeley, CA (United States); Martinez, M. [Sapienza Universita di Roma, Dipartimento di Fisica, Rome (Italy); INFN-Sezione di Roma, Rome (Italy); Universidad de Zaragoza, Laboratorio de Fisica Nuclear y Astroparticulas, Saragossa (Spain); Moggi, N.; Zucchelli, S. [INFN-Sezione di Bologna, Bologna (Italy); Universita di Bologna - Alma Mater Studiorum, Dipartimento di Fisica e Astronomia, Bologna (IT); Nones, C. [CEA/Saclay, Service de Physique des Particules, Gif-sur-Yvette (FR); Norman, E.B.; Wang, B.S. [Lawrence Livermore National Laboratory, Livermore, CA (US); University of California, Department of Nuclear Engineering, Berkeley, CA (US); O' Donnell, T. [Virginia Polytechnic Institute and State University, Center for Neutrino Physics, Blacksburg, VA (US); Sangiorgio, S.; Scielzo, N.D. [Lawrence Livermore National Laboratory, Livermore, CA (US); Wise, T. [Yale University, Department of Physics, New Haven, CT (US); University of Wisconsin, Department of Physics, Madison, WI (US); Woodcraft, A. [University of Edinburgh, SUPA, Institute for Astronomy, Edinburgh (GB); Zimmermann, S. [Lawrence Berkeley National Laboratory, Engineering Division, Berkeley, CA (US)

    2017-12-15

    CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of {sup 130}Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searches requires improving the energy threshold to 10 keV. In this paper, we describe the analysis techniques developed for the low energy analysis of CUORE-like detectors, using the data acquired from November 2013 to March 2015 by CUORE-0, a single-tower prototype designed to validate the assembly procedure and new cleaning techniques of CUORE. We explain the energy threshold optimization, continuous monitoring of the trigger efficiency, data and event selection, and energy calibration at low energies in detail. We also present the low energy background spectrum of CUORE-0 below 60 keV. Finally, we report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0 energy threshold and background, as well as an estimate of the uncertainty on the nuclear quenching factor from nuclear recoils in CUORE-0. (orig.)

  6. Machine monitoring via current signature analysis techniques

    International Nuclear Information System (INIS)

    Smith, S.F.; Castleberry, K.N.; Nowlin, C.H.

    1992-01-01

    A significant need in the effort to provide increased production quality is to provide improved plant equipment monitoring capabilities. Unfortunately, in today's tight economy, even such monitoring instrumentation must be implemented in a recognizably cost effective manner. By analyzing the electric current drawn by motors, actuator, and other line-powered industrial equipment, significant insights into the operations of the movers, driven equipment, and even the power source can be obtained. The generic term 'current signature analysis' (CSA) has been coined to describe several techniques for extracting useful equipment or process monitoring information from the electrical power feed system. A patented method developed at Oak Ridge National Laboratory is described which recognizes the presence of line-current modulation produced by motors and actuators driving varying loads. The in-situ application of applicable linear demodulation techniques to the analysis of numerous motor-driven systems is also discussed. The use of high-quality amplitude and angle-demodulation circuitry has permitted remote status monitoring of several types of medium and high-power gas compressors in (US DOE facilities) driven by 3-phase induction motors rated from 100 to 3,500 hp, both with and without intervening speed increasers. Flow characteristics of the compressors, including various forms of abnormal behavior such as surging and rotating stall, produce at the output of the specialized detectors specific time and frequency signatures which can be easily identified for monitoring, control, and fault-prevention purposes. The resultant data are similar in form to information obtained via standard vibration-sensing techniques and can be analyzed using essentially identical methods. In addition, other machinery such as refrigeration compressors, brine pumps, vacuum pumps, fans, and electric motors have been characterized

  7. Computational Chemical Synthesis Analysis and Pathway Design

    Directory of Open Access Journals (Sweden)

    Fan Feng

    2018-06-01

    Full Text Available With the idea of retrosynthetic analysis, which was raised in the 1960s, chemical synthesis analysis and pathway design have been transformed from a complex problem to a regular process of structural simplification. This review aims to summarize the developments of computer-assisted synthetic analysis and design in recent years, and how machine-learning algorithms contributed to them. LHASA system started the pioneering work of designing semi-empirical reaction modes in computers, with its following rule-based and network-searching work not only expanding the databases, but also building new approaches to indicating reaction rules. Programs like ARChem Route Designer replaced hand-coded reaction modes with automatically-extracted rules, and programs like Chematica changed traditional designing into network searching. Afterward, with the help of machine learning, two-step models which combine reaction rules and statistical methods became the main stream. Recently, fully data-driven learning methods using deep neural networks which even do not require any prior knowledge, were applied into this field. Up to now, however, these methods still cannot replace experienced human organic chemists due to their relatively low accuracies. Future new algorithms with the aid of powerful computational hardware will make this topic promising and with good prospects.

  8. Chemical analysis developments for fusion materials studies

    International Nuclear Information System (INIS)

    McCown, J.J.; Baldwin, D.L.; Keough, R.F.; Van der Cook, B.P.

    1985-04-01

    Several projects at Hanford under the management of the Westinghouse Hanford Company have involved research and development (R and D) on fusion materials. They include work on the Fusion Materials Irradiation Test Facility and its associated Experimental Lithium System; testing of irradiated lithium compounds as breeding materials; and testing of Li and Li-Pb alloy reactions with various atmospheres, concrete, and other reactor materials for fusion safety studies. In the course of these projects, a number of interesting and challenging analytical chemistry problems were encountered. They include sampling and analysis of lithium while adding and removing elements of interest; sampling, assaying and compound identification efforts on filters, aerosol particles and fire residues; development of dissolution and analysis techniques for measuring tritium and helium in lithium ceramics including oxides, aluminates, silicates and zirconates. An overview of the analytical chemistry development problems plus equipment and procedures used will be presented

  9. Construction of a technique plan repository and evaluation system based on AHP group decision-making for emergency treatment and disposal in chemical pollution accidents

    International Nuclear Information System (INIS)

    Shi, Shenggang; Cao, Jingcan; Feng, Li; Liang, Wenyan; Zhang, Liqiu

    2014-01-01

    Highlights: • Different chemical pollution accidents were simplified using the event tree analysis. • Emergency disposal technique plan repository of chemicals accidents was constructed. • The technique evaluation index system of chemicals accidents disposal was developed. • A combination of group decision and analytical hierarchy process (AHP) was employed. • Group decision introducing similarity and diversity factor was used for data analysis. - Abstract: The environmental pollution resulting from chemical accidents has caused increasingly serious concerns. Therefore, it is very important to be able to determine in advance the appropriate emergency treatment and disposal technology for different types of chemical accidents. However, the formulation of an emergency plan for chemical pollution accidents is considerably difficult due to the substantial uncertainty and complexity of such accidents. This paper explains how the event tree method was used to create 54 different scenarios for chemical pollution accidents, based on the polluted medium, dangerous characteristics and properties of chemicals involved. For each type of chemical accident, feasible emergency treatment and disposal technology schemes were established, considering the areas of pollution source control, pollutant non-proliferation, contaminant elimination and waste disposal. Meanwhile, in order to obtain the optimum emergency disposal technology schemes as soon as the chemical pollution accident occurs from the plan repository, the technique evaluation index system was developed based on group decision-improved analytical hierarchy process (AHP), and has been tested by using a sudden aniline pollution accident that occurred in a river in December 2012

  10. Construction of a technique plan repository and evaluation system based on AHP group decision-making for emergency treatment and disposal in chemical pollution accidents

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Shenggang [College of Environmental Science and Engineering, Beijing Forestry University, Beijing 100083 (China); College of Chemistry, Baotou Teachers’ College, Baotou 014030 (China); Cao, Jingcan; Feng, Li; Liang, Wenyan [College of Environmental Science and Engineering, Beijing Forestry University, Beijing 100083 (China); Zhang, Liqiu, E-mail: zhangliqiu@163.com [College of Environmental Science and Engineering, Beijing Forestry University, Beijing 100083 (China)

    2014-07-15

    Highlights: • Different chemical pollution accidents were simplified using the event tree analysis. • Emergency disposal technique plan repository of chemicals accidents was constructed. • The technique evaluation index system of chemicals accidents disposal was developed. • A combination of group decision and analytical hierarchy process (AHP) was employed. • Group decision introducing similarity and diversity factor was used for data analysis. - Abstract: The environmental pollution resulting from chemical accidents has caused increasingly serious concerns. Therefore, it is very important to be able to determine in advance the appropriate emergency treatment and disposal technology for different types of chemical accidents. However, the formulation of an emergency plan for chemical pollution accidents is considerably difficult due to the substantial uncertainty and complexity of such accidents. This paper explains how the event tree method was used to create 54 different scenarios for chemical pollution accidents, based on the polluted medium, dangerous characteristics and properties of chemicals involved. For each type of chemical accident, feasible emergency treatment and disposal technology schemes were established, considering the areas of pollution source control, pollutant non-proliferation, contaminant elimination and waste disposal. Meanwhile, in order to obtain the optimum emergency disposal technology schemes as soon as the chemical pollution accident occurs from the plan repository, the technique evaluation index system was developed based on group decision-improved analytical hierarchy process (AHP), and has been tested by using a sudden aniline pollution accident that occurred in a river in December 2012.

  11. Comparative Analysis on Chemical Composition of Bentonite Clays ...

    African Journals Online (AJOL)

    2017-09-12

    Sep 12, 2017 ... Comparative Analysis on Chemical Composition of Bentonite Clays. Obtained from Ashaka and ... versatile material for geotechnical engineering and as well as their demand for ..... A PhD thesis submitted to the Chemical ...

  12. Cost analysis and estimating tools and techniques

    CERN Document Server

    Nussbaum, Daniel

    1990-01-01

    Changes in production processes reflect the technological advances permeat­ ing our products and services. U. S. industry is modernizing and automating. In parallel, direct labor is fading as the primary cost driver while engineering and technology related cost elements loom ever larger. Traditional, labor-based ap­ proaches to estimating costs are losing their relevance. Old methods require aug­ mentation with new estimating tools and techniques that capture the emerging environment. This volume represents one of many responses to this challenge by the cost analysis profession. The Institute of Cost Analysis (lCA) is dedicated to improving the effective­ ness of cost and price analysis and enhancing the professional competence of its members. We encourage and promote exchange of research findings and appli­ cations between the academic community and cost professionals in industry and government. The 1990 National Meeting in Los Angeles, jointly spo~sored by ICA and the National Estimating Society (NES),...

  13. Population estimation techniques for routing analysis

    International Nuclear Information System (INIS)

    Sathisan, S.K.; Chagari, A.K.

    1994-01-01

    A number of on-site and off-site factors affect the potential siting of a radioactive materials repository at Yucca Mountain, Nevada. Transportation related issues such route selection and design are among them. These involve evaluation of potential risks and impacts, including those related to population. Population characteristics (total population and density) are critical factors in the risk assessment, emergency preparedness and response planning, and ultimately in route designation. This paper presents an application of Geographic Information System (GIS) technology to facilitate such analyses. Specifically, techniques to estimate critical population information are presented. A case study using the highway network in Nevada is used to illustrate the analyses. TIGER coverages are used as the basis for population information at a block level. The data are then synthesized at tract, county and state levels of aggregation. Of particular interest are population estimates for various corridor widths along transport corridors -- ranging from 0.5 miles to 20 miles in this paper. A sensitivity analysis based on the level of data aggregation is also presented. The results of these analysis indicate that specific characteristics of the area and its population could be used as indicators to aggregate data appropriately for the analysis

  14. Novel chemical analysis for thin films

    International Nuclear Information System (INIS)

    Usui, Toshio; Kamei, Masayuki; Aoki, Yuji; Morishita, Tadataka; Tanaka, Shoji

    1991-01-01

    Scanning electron microscopy and total-reflection-angle X-ray spectroscopy (SEM-TRAXS) was applied for fluorescence X-ray analysis of 50A- and 125A-thick Au thin films on Si(100). The intensity of the AuM line (2.15 keV) emitted from the Au thin films varied as a function of the take-off angle (θ t ) with respect to the film surface; the intensity of AuM line from the 125A-thick Au thin film was 1.5 times as large as that of SiK α line (1.74 keV) emitted from the Si substrate when θ t = 0deg-3deg, in the vicinity of a critical angle for total external reflection of the AuM line at Si (0.81deg). In addition, the intensity of the AuM line emitted from the 50A-thick Au thin film was also sufficiently strong for chemical analysis. (author)

  15. Radio-analysis. Definitions and techniques

    International Nuclear Information System (INIS)

    Bourrel, F.; Courriere, Ph.

    2003-01-01

    This paper presents the different steps of the radio-labelling of a molecule for two purposes: the radio-immuno-analysis and the auto-radiography: 1 - definitions, radiations and radioprotection: activity of a radioactive source; half-life; radioactivity (alpha-, beta- and gamma radioactivity, internal conversion); radioprotection (irradiation, contamination); 2 - radionuclides used in medical biology and obtention of labelled molecules: gamma emitters ( 125 I, 57 Co); beta emitters; obtention of labelled molecules (general principles, high specific activity and choice of the tracer, molecule to be labelled); main labelling techniques (iodation, tritium); purification of the labelled compound (dialysis, gel-filtering or molecular exclusion chromatography, high performance liquid chromatography); quality estimation of the labelled compound (labelling efficiency calculation, immuno-reactivity conservation, stability and preservation). (J.S.)

  16. Flame analysis using image processing techniques

    Science.gov (United States)

    Her Jie, Albert Chang; Zamli, Ahmad Faizal Ahmad; Zulazlan Shah Zulkifli, Ahmad; Yee, Joanne Lim Mun; Lim, Mooktzeng

    2018-04-01

    This paper presents image processing techniques with the use of fuzzy logic and neural network approach to perform flame analysis. Flame diagnostic is important in the industry to extract relevant information from flame images. Experiment test is carried out in a model industrial burner with different flow rates. Flame features such as luminous and spectral parameters are extracted using image processing and Fast Fourier Transform (FFT). Flame images are acquired using FLIR infrared camera. Non-linearities such as thermal acoustic oscillations and background noise affect the stability of flame. Flame velocity is one of the important characteristics that determines stability of flame. In this paper, an image processing method is proposed to determine flame velocity. Power spectral density (PSD) graph is a good tool for vibration analysis where flame stability can be approximated. However, a more intelligent diagnostic system is needed to automatically determine flame stability. In this paper, flame features of different flow rates are compared and analyzed. The selected flame features are used as inputs to the proposed fuzzy inference system to determine flame stability. Neural network is used to test the performance of the fuzzy inference system.

  17. Analysis of obsidians by PIXE technique

    International Nuclear Information System (INIS)

    Nuncio Q, A.E.

    1998-01-01

    This work presents the characterization of obsydian samples from different mineral sites in Mexico, undertaken by an Ion Beam Analysis: PIXE (Proton Induced X-ray Emission). As part of an intensive investigation of obsidian in Mesoamerica by anthropologists from Mexico National Institute of Anthropology and History, 818 samples were collected from different volcanic sources in central Mexico for the purpose of establishing a data bank of element concentrations of each source. Part of this collection was analyzed by Neutron activation analysis and most of the important elements concentrations reported. In this work, a non-destructive IBA technique (PIXE) are used to analyze obsydian samples. The application of this technique were carried out at laboratories of the ININ Nuclear Center facilities. The samples consisted of of obsydians from ten different volcanic sources. This pieces were mounted on a sample holder designed for the purpose of exposing each sample to the proton beam. This PIXE analysis was carried out with an ET Tandem Accelerator at the ININ. X-ray spectrometry was carried out with an external beam facility employing a Si(Li) detector set at 52.5 degrees in relation to the target normal (parallel to the beam direction) and 4.2 cm away from the target center. A filter was set in front of the detector, to determine the best attenuation conditions to obtain most of the elements, taking into account that X-ray spectra from obsydians are dominated by intense major elements lines. Thus, a 28 μ m- thick aluminium foil absorber was selected and used to reduce the intensity of the major lines as well as pile-up effects. The mean proton energy was 2.62 MeV, and the beam profile was about 4 mm in diameter. As results were founded elemental concentrations of a set of samples from ten different sources: Altotonga (Veracruz), Penjamo (Guanajuato), Otumba (Mexico), Zinapecuaro (Michoacan), Ucareo (Michoacan), Tres Cabezas (Puebla), Sierra Navajas (Hidalgo), Zaragoza

  18. The study of metal sulphide nanomaterials obtained by chemical bath deposition and hot-injection technique

    Science.gov (United States)

    Maraeva, E. V.; Alexandrova, O. A.; Forostyanaya, N. A.; Levitskiy, V. S.; Mazing, D. S.; Maskaeva, L. N.; Markov, V. Ph; Moshnikov, V. A.; Shupta, A. A.; Spivak, Yu M.; Tulenin, S. S.

    2015-11-01

    In this study lead sulphide - cadmium sulphide based layers were obtained through chemical deposition of water solutions and cadmium sulphide quantum dots were formed through hot-injection technique. The article discusses the results of surface investigations with the use of atomic force microscopy, Raman spectroscopy and photoluminescence measurements.

  19. The study of metal sulphide nanomaterials obtained by chemical bath deposition and hot-injection technique

    International Nuclear Information System (INIS)

    Maraeva, E V; Alexandrova, O A; Levitskiy, V S; Mazing, D S; Moshnikov, V A; Shupta, A A; Spivak, Yu M; Forostyanaya, N A; Maskaeva, L N; Markov, V Ph; Tulenin, S S

    2015-01-01

    In this study lead sulphide – cadmium sulphide based layers were obtained through chemical deposition of water solutions and cadmium sulphide quantum dots were formed through hot-injection technique. The article discusses the results of surface investigations with the use of atomic force microscopy, Raman spectroscopy and photoluminescence measurements. (paper)

  20. Laser speckle technique to study the effect of chemical pre-treatment on the quality of minimally processed apples

    International Nuclear Information System (INIS)

    Minz, Preeti D; Nirala, A K

    2016-01-01

    In the present study, the laser speckle technique has been used for the quality evaluation of chemically treated cut apples. Chemical pre-treatment includes 1% (w/v) solution of citric acid (CA), sodium chloride (SC), and a combination of CA and sodium chloride (CS). The variation in weight loss, respiration rate, total soluble solids (TSS), titratable acidity (TA), and absorbance of chemically treated cut apples stored at 5 °C was monitored for 11 d. The speckle grain size was calculated by an autocovariance method from the speckled images of freshly cut chemically treated apples. The effect of chemicals on TSS and the TA content variation of the cut apples were well correlated to the linear speckle grain size. Circular degree of polarization confirms the presence of a small scatterer and hence Rayleigh diffusion region. For all the treated cut apples, a decrease in the concentration of small particles nearly after the mid-period of storage results in the fast decay of circular degree of polarization. For non-invasive and fast analysis of the chemical constituent of fruits during minimal processing, the laser speckle can be practically used in the food industry. (paper)

  1. Laser speckle technique to study the effect of chemical pre-treatment on the quality of minimally processed apples

    Science.gov (United States)

    Minz, Preeti D.; Nirala, A. K.

    2016-04-01

    In the present study, the laser speckle technique has been used for the quality evaluation of chemically treated cut apples. Chemical pre-treatment includes 1% (w/v) solution of citric acid (CA), sodium chloride (SC), and a combination of CA and sodium chloride (CS). The variation in weight loss, respiration rate, total soluble solids (TSS), titratable acidity (TA), and absorbance of chemically treated cut apples stored at 5 °C was monitored for 11 d. The speckle grain size was calculated by an autocovariance method from the speckled images of freshly cut chemically treated apples. The effect of chemicals on TSS and the TA content variation of the cut apples were well correlated to the linear speckle grain size. Circular degree of polarization confirms the presence of a small scatterer and hence Rayleigh diffusion region. For all the treated cut apples, a decrease in the concentration of small particles nearly after the mid-period of storage results in the fast decay of circular degree of polarization. For non-invasive and fast analysis of the chemical constituent of fruits during minimal processing, the laser speckle can be practically used in the food industry.

  2. Handbook of Qualitative Research Techniques and Analysis in Entrepreneurship

    DEFF Research Database (Denmark)

    One of the most challenging tasks in the research design process is choosing the most appropriate data collection and analysis techniques. This Handbook provides a detailed introduction to five qualitative data collection and analysis techniques pertinent to exploring entreprneurial phenomena....

  3. Thermodynamic analysis of chemical heat pumps

    International Nuclear Information System (INIS)

    Obermeier, Jonas; Müller, Karsten; Arlt, Wolfgang

    2015-01-01

    Thermal energy storages and heat pump units represent an important part of high efficient renewable energy systems. By using thermally driven, reversible chemical reactions a combination of thermal energy storage and heat pump can be realized. The influences of thermophysical properties of the involved components on the efficiency of a heat pump cycle is analysed and the relevance of the thermodynamic driving force is worked out. In general, the behaviour of energetic and exergetic efficiency is contrary. In a real cycle, higher enthalpies of reaction decrease the energetic efficiency but increase the exergetic efficiency. Higher enthalpies of reaction allow for lower offsets from equilibrium state for a default thermodynamic driving force of the reaction. - Highlights: • A comprehensive efficiency analysis of gas-solid heat pumps is proposed. • Link between thermodynamic driving force and equilibrium drop is shown. • Calculation of the equilibrium drop based on thermochemical properties. • Reaction equilibria of the decomposition reaction of salt hydrates. • Contrary behavior of energetic and exergetic efficiency

  4. Exogenous bleaching evaluation on dentin using chemical activated technique compared with diode laser technique

    International Nuclear Information System (INIS)

    Carvalho, Breno Carnevalli Franco de

    2003-01-01

    This in vitro study compared the results of different exogenous bleaching proceedings on dentin after treatment of enamel surface. Thirty human canine were hewn preserving the vestibular half of the crown and 3 mm of root, showing a vestibular-lingual thickness average of 3,5 mm, measuring in the third middle of the crown. Ali teeth were maintained in wet chamber during the experiment. Digital photographs were taken of the dentin surface at 3 experimental times (LI: initial record, L0: immediate pos-bleaching record and L 15: 15 days after bleaching). The teeth were divided into 3 experimental groups of 10 teeth in each. The Control Group did not receive any kind of treatment. The Laser Group received 2 session of laser bleaching, with 3 applications each, using 35% hydrogen peroxide, activated by diode laser during 30 seconds, by scanning the enamel surface from incisal edge to the top of the crown, from mesial to distal portion of the crown and circularly, each movement during 10 seconds. The following parameters being adopted: wavelength of 808 nm, power of 1,5 W and optic fiber with 600 μm (core). The Peroxide Group received 28 daily applications, during 4 hours each application, using 16% carbamide peroxide. The bleaching records were analysed using a computer, through RGBK (red, green , blue and black). The K averages (K=100% for black and K=0% for white) of the records for Control Group were: LI=50,1 %, L0=50,3% and L 15=50,6%. For Laser Group the K averages were LI=48,5%, L0=50,0% and L 15=47,7%. And for the Peroxide Group were LI=50,5%, L0=35,9% and L 15=37,3%. The statistical analysis showed no significant difference of the K between the Control Group and the Laser Group, as to LI, L0 and L 15. Only Peroxide Group showed significant statistical difference between LI with L0 and L 15 (0,1%), and L0 in comparison with L 15 did not show any difference. (author)

  5. Techniques and Applications of Urban Data Analysis

    KAUST Repository

    AlHalawani, Sawsan N.

    2016-05-26

    Digitization and characterization of urban spaces are essential components as we move to an ever-growing ’always connected’ world. Accurate analysis of such digital urban spaces has become more important as we continue to get spatial and social context-aware feedback and recommendations in our daily activities. Modeling and reconstruction of urban environments have thus gained unprecedented importance in the last few years. Such analysis typically spans multiple disciplines, such as computer graphics, and computer vision as well as architecture, geoscience, and remote sensing. Reconstructing an urban environment usually requires an entire pipeline consisting of different tasks. In such a pipeline, data analysis plays a strong role in acquiring meaningful insights from the raw data. This dissertation primarily focuses on the analysis of various forms of urban data and proposes a set of techniques to extract useful information, which is then used for different applications. The first part of this dissertation presents a semi-automatic framework to analyze facade images to recover individual windows along with their functional configurations such as open or (partially) closed states. The main advantage of recovering both the repetition patterns of windows and their individual deformation parameters is to produce a factored facade representation. Such a factored representation enables a range of applications including interactive facade images, improved multi-view stereo reconstruction, facade-level change detection, and novel image editing possibilities. The second part of this dissertation demonstrates the importance of a layout configuration on its performance. As a specific application scenario, I investigate the interior layout of warehouses wherein the goal is to assign items to their storage locations while reducing flow congestion and enhancing the speed of order picking processes. The third part of the dissertation proposes a method to classify cities

  6. Numerical modeling techniques for flood analysis

    Science.gov (United States)

    Anees, Mohd Talha; Abdullah, K.; Nawawi, M. N. M.; Ab Rahman, Nik Norulaini Nik; Piah, Abd. Rahni Mt.; Zakaria, Nor Azazi; Syakir, M. I.; Mohd. Omar, A. K.

    2016-12-01

    Topographic and climatic changes are the main causes of abrupt flooding in tropical areas. It is the need to find out exact causes and effects of these changes. Numerical modeling techniques plays a vital role for such studies due to their use of hydrological parameters which are strongly linked with topographic changes. In this review, some of the widely used models utilizing hydrological and river modeling parameters and their estimation in data sparse region are discussed. Shortcomings of 1D and 2D numerical models and the possible improvements over these models through 3D modeling are also discussed. It is found that the HEC-RAS and FLO 2D model are best in terms of economical and accurate flood analysis for river and floodplain modeling respectively. Limitations of FLO 2D in floodplain modeling mainly such as floodplain elevation differences and its vertical roughness in grids were found which can be improve through 3D model. Therefore, 3D model was found to be more suitable than 1D and 2D models in terms of vertical accuracy in grid cells. It was also found that 3D models for open channel flows already developed recently but not for floodplain. Hence, it was suggested that a 3D model for floodplain should be developed by considering all hydrological and high resolution topographic parameter's models, discussed in this review, to enhance the findings of causes and effects of flooding.

  7. Cosmetics chemical composition characterization by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Ana Paula; Pereira, Gustavo Jose; Amaral, Angela Maria; Ferreira, Andrea Vidal, E-mail: ana_allves2008@hotmail.co [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2009-07-01

    Brazil is in the third position in the world's cosmetics market. It is an expanding and growing market where new products and manufacturing processes are in a constant and steady expansion. Therefore, it is mandatory that the composition of the products is well known in order to guarantee safety and quality of daily used cosmetics. The Brazilian National Health Surveillance Agency (ANVISA) has issued a resolution, RDC No. 48, March 16, 2006, which defines a 'List of Substances which can not be used in personal hygiene products, cosmetics and perfumes'. In this work, samples of locally manufactured and imported cosmetics (lipsticks, eye shadows, etc.) were analyzed using the Instrumental Neutron Activation Analysis technique. The samples were irradiated in the TRIGA IPR-R1 reactor of the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN), on a 100kW thermal power, with a thermal neutron fluence rate about 8x10{sup 11}ncm{sup -2}s{sup -1}. The analysis has detected the chemical elements Br, Ba, Ga, Na, K, Sc, Fe, Cr, Zn, Sm, W, La, Rb, Cs, Ta, Ge, Co, U, Ti, V, Cl, Al, Mn and Cu. The concentrations of these elements are on a range from 5 to 3000mug.g{sup -1}. Some chemical elements observed in samples (Cl, Br, Cr, U) are included at ANVISA prohibitive list. (author)

  8. Cosmetics chemical composition characterization by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Alves, Ana Paula; Pereira, Gustavo Jose; Amaral, Angela Maria; Ferreira, Andrea Vidal

    2009-01-01

    Brazil is in the third position in the world's cosmetics market. It is an expanding and growing market where new products and manufacturing processes are in a constant and steady expansion. Therefore, it is mandatory that the composition of the products is well known in order to guarantee safety and quality of daily used cosmetics. The Brazilian National Health Surveillance Agency (ANVISA) has issued a resolution, RDC No. 48, March 16, 2006, which defines a 'List of Substances which can not be used in personal hygiene products, cosmetics and perfumes'. In this work, samples of locally manufactured and imported cosmetics (lipsticks, eye shadows, etc.) were analyzed using the Instrumental Neutron Activation Analysis technique. The samples were irradiated in the TRIGA IPR-R1 reactor of the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN), on a 100kW thermal power, with a thermal neutron fluence rate about 8x10 11 ncm -2 s -1 . The analysis has detected the chemical elements Br, Ba, Ga, Na, K, Sc, Fe, Cr, Zn, Sm, W, La, Rb, Cs, Ta, Ge, Co, U, Ti, V, Cl, Al, Mn and Cu. The concentrations of these elements are on a range from 5 to 3000μg.g -1 . Some chemical elements observed in samples (Cl, Br, Cr, U) are included at ANVISA prohibitive list. (author)

  9. availability analysis of chemicals for water treatment

    African Journals Online (AJOL)

    NIJOTECH

    In most countries, chemicals are generally recognized as being vital in the production of potable water and will ... industries and water utility ventures are being started in Nigeria ... are being dumped into rivers thereby polluting them the more.

  10. Analysis of the chemical elements behavior in leaves infected with fumagina employing X-ray fluorescence technique; Analise do comportamento de elementos quimicos em folhas infectadas com fumagina atraves da tecnica de fluorescencia de raios-X

    Energy Technology Data Exchange (ETDEWEB)

    Blonski, Maria Selia

    2002-02-01

    Fumagina is produced by the Capnodium fungi, a mushroom from Dothideales order, that lives associated with the yellow aphid (Monelliopsis pecanis), excreting a heavy load of a sugared substance that provides the sooty fungus development, covering, in some cases the totality, of leaves, fruits and branches surfaces. One of the big problems caused by this disease is the physic photosynthesis stuckness, reducing in 98% the active photosynthesis radiation and in 70% the net photosynthesis. This photosynthesis reduction affects the plants carbohydrate reservoirs, resulting in reduced and bad qualified crops. It was employed the Energy Dispersion X-Ray Fluorescence Technique (EDXRF) to study the fumagina disease. The measurements were realized with infected and healthy leaves of citric plants (orange and lemon trees), collected at the Farm School of the State University of Londrina, and also leaves of icsora plant from Piracicaba-SP. Through this technique it was observed a metabolic disorder related to Fe and Ca elements. By comparing the EDXRF spectra of the healthy plant leaves with the infected ones, it was verified that the concentration of Ca is higher than the concentration Fe in leaves of healthy plants, while for the leaves of plants infected with fumagina, it was observed a higher concentration of Fe. Employing EDXRF and the emission/transmission method for the matrix effect correction, samples of the citric plants were also analysed in pellet. The elements K, Ca, Ti, Mn , Fe, Cu and Zn were quantified. It was verified a higher Fe concentration in fumagina samples compared to the samples without fumagina. For all the elements of interest the minimum level of detection found was at the order of {mu}g g{sup -1}. (author)

  11. Quantitative blood flow analysis with digital techniques

    International Nuclear Information System (INIS)

    Forbes, G.

    1984-01-01

    The general principles of digital techniques in quantitating absolute blood flow during arteriography are described. Results are presented for a phantom constructed to correlate digitally calculated absolute flow with direct flow measurements. The clinical use of digital techniques in cerebrovascular angiography is briefly described. (U.K.)

  12. Physico-Chemical Analysis and Sensory Evaluation of Bread

    African Journals Online (AJOL)

    Shuaibu et al.

    Physico-Chemical Analysis and Sensory Evaluation of Bread Produced Using ... analysis of the bread samples revealed that the moisture content ..... 72. Jarup, L. ,2003. Hazards of heavy metal contamination. Br Med. Bull; 68, pp.167-82.

  13. Chemical analysis and base-promoted hydrolysis of locally ...

    African Journals Online (AJOL)

    Abstract. The study was on the chemical analysis and base- promoted hydrolysis of extracted shea nut fat. The local method of extraction of the shea nut oil was employed in comparison with literature report. A simple cold-process alkali hydrolysis of the shea nut oil was used in producing the soap. The chemical analysis of ...

  14. Some comments on misuse of terms related to chemical analysis

    International Nuclear Information System (INIS)

    Steinnes, E.

    2007-01-01

    Complet text of publication follows. I have been involved in scientific studies involving chemical analysis for more than 49 years. Over this period I have observed an increasing tendency to incorrect use of terms 'analysis' and 'determination' and the corresponding verbum forms. According to correct terminology in English, samples are analyzed, analytes (e.g., trace elements) are determined. However, too often expressions such as 'analysis of copper in blood' are seen in the literature, especially in papers written by non-chemists. The reason why I am raising this point at the present time in that I observed the problem in several recent titles of papers published over the last few years in the Journal of Radioanalytical and Nuclear Chemistry: Preconcentration and neutron activation analysis of thorium and uranium in natural waters. Use of activated carbon as pre-separation agent in NAA of selenium, cobalt and iodine. Recent developments in the analysis of transuranics (Np, Pu, Am) in sea water. Automated radiochemical analysis of total 99 Tc in aged nuclear waste processing streams. Photon activation analysis of carbon in glasses for fiber amplifiers by using the flow method for the rapid separation of 11 C. Preconcentration neutron activation analysis of lanthanides by cloudpoint extraction using PAN. Analysis of the chemical elements in leaves infected by fumagina by X-ray fluorescence technique. Rapid method for 226 Ra and 228 Ra analysis in water samples. The above list is far from exhaustive. I believe that this incorrect use of terminology should be avoided at least in the titles of scientific papers, in Journal of Radioanalytical and Nuclear Chemistry as well as in other scientific journals. In some of the above cases replacing 'of' with 'for the determination of', or just with 'for', would have solved the problem. In other cases it would be preferable to reverse the order of words in the sentence, such as e.g., 'Determination of selenium, cobalt and

  15. Performance of the In Situ Microcosm Technique for Measuring the Degradation of Organic Chemicals in Aquifers

    DEFF Research Database (Denmark)

    Nielsen, Per H.; Christensen, Thomas Højlund; Albrechtsen, Hans-Jørgen

    1996-01-01

    chemicals in polluted and pristine aquifers representing different redox environments. The ISM technique has great potential for providing field-relevant degradation potentials and rate constants, but care must be taken in using the equipment and interpreting the results. This paper provides details......An in situ microcosm (ISM) consists of a stainless steel cylinder isolating about 2 L of the aquifer and is equipped with valves allowing for loading and sampling from the ground surface. During the last five years, this technique has been used frequently to study the degradation of organic...

  16. Advanced chemical quality control techniques for use in the manufacture of (U-Pu) MOX fuels

    International Nuclear Information System (INIS)

    Panakkal, J.P.; Prakash, Amrit

    2010-01-01

    Analytical chemistry plays a very important role for nuclear fuel cycle activities be it fuel fabrication, waste management or reprocessing. Nuclear fuels are selected based on the type of reactor. The nuclear fuel has to conform to various stringent chemical specifications like B, rare earths, H, O/M heavy metal content etc. Selection of technique is very important to determine the true specification. This is important particularly when the analyses has to be performed inside leak tight enclosure. The present paper describes the details of the advanced techniques being developed and used in the manufacture of (U,Pu) MOX fuels. (author)

  17. Speciation analysis of I-127,129 in the crop field soil contaminated by the Fukushima Dai-ichi nuclear power plant accident with newly developed chemical separation techniques

    Science.gov (United States)

    Honda, Maki; Matsuzaki, Hiroyuki; Saito, Takumi; Nagai, Hisao

    2014-05-01

    In previous study, we investigated the depth profile of the accident derived I-129 and downward migration speed in soils of near-field of Fukushima Dai-ichi Nuclear Power Plant, including crop fields and man-made fields. I-129 in soil was measured by AMS and stable iodine (I-127) was measured by ICP-MS at MALT (Micro Analysis Laboratory, Tandem accelerator), The University of Tokyo. It was found that I-129 was concentrated near surface but distributed deeper compared with Cs-137. It was also found that I-129 seems to move downward more quickly than Cs-137. To investigate the adsorption mechanism and the elemental process of migration of the accident derived I-129 in soil, it is important to know what kind of component the I-129 combines with. Recent studies on the X-ray absorption fine structure (XAFS), especially near edge structure (XANES), reported that the stable iodine (I-127) in soil existed as an organic component. However, it had not yet been proved that it was also the case with the accident derived I-129 because it had been incorporated in the soil system only recently and the abundance of I-129 in soil was more than 8 orders of magnitude smaller than sub-ppm level stable iodine (I-127). In this study a progressive sequential extraction method including the dialysis and the dynamic headspace method was newly developed to obtain only the iodine sticking to the soil organic component. The stable iodine can be quantified by direct analysis of the fraction and I-129 can be quantified by AMS method of the fraction added with carrier. The fraction of the organic component for I-127 and I-129 can be evaluated respectively by comparing with the other fraction and/or with the total concentration obtained by the bulk analysis (e.g. by the pyrohydrolysis).

  18. Roles of Ag in fabricating Si nanowires by the electroless chemical etching technique

    International Nuclear Information System (INIS)

    Wan, X.; Wang, Q. K.; Wangyang, P. H.; Tao, H.

    2012-01-01

    Silicon wafers coated with a film of Ag pattern are used for investigating roles of Ag in the fabrication of silicon nanowire arrays (SiNWs) by the electroless chemical etching technique. The diameter of SiNWs grown in the mixed AgNO 3 /HF solution ranges from 20 to 250 nm. A growth mechanism for such obtained SiNWs is proposed and further experimentally verified. As a comparison as well as to better understand this chemical process, another popular topic on growing SiNWs in the H 2 O 2 /HF solution is also studied. Originating from different chemical reaction mechanisms, Ag film could protect the underneath Si in the AgNO 3 /HF solution and it could, on the contrary, accelerate etching of the underneath Si in the H 2 O 2 /HF solution.

  19. Thermoluminescence as a complementary technique for the toxicological evaluation of chemicals in photosynthetic organisms

    Energy Technology Data Exchange (ETDEWEB)

    Repetto, Guillermo, E-mail: grepkuh@upo.es [Departamento de Biología Molecular e Ingeniería Bioquímica, Área de Toxicología, Universidad Pablo de Olavide, Carretera de Utrera km. 1, 41013 Seville (Spain); Zurita, Jorge L. [Departamento de Biología Molecular e Ingeniería Bioquímica, Área de Toxicología, Universidad Pablo de Olavide, Carretera de Utrera km. 1, 41013 Seville (Spain); Roncel, Mercedes; Ortega, José M. [Instituto de Bioquímica Vegetal y Fotosíntesis, Universidad de Sevilla-CSIC, Américo Vespucio 49, 41092 Seville (Spain)

    2015-01-15

    Highlights: • There are very few toxicological applications of thermoluminescence. • It is a luminescence emission induced by heating the sample in the dark. • It is useful for study the photosystem II function and the level of lipid peroxidation. - Abstract: Thermoluminescence is a simple technique very useful for studying electron transfer reactions on photosystem II (standard thermoluminescence) or the level of lipid peroxidation in membranes (high temperature thermoluminescence) in photosynthetic organisms. Both techniques were used to investigate the effects produced on Chlorella vulgaris cells by six compounds: the chemical intermediates bromobenzene and diethanolamine, the antioxidant propyl gallate, the semiconductor indium nitrate, the pesticide sodium monofluoroacetate and the antimalarial drug chloroquine. Electron transfer activity of the photosystem II significantly decreased after the exposure of Chlorella cells to all the six chemicals used. Lipid peroxidation was slightly decreased by the antioxidant propyl gallate, not changed by indium nitrate and very potently stimulated by diethanolamine, chloroquine, sodium monofluoroacetate and bromobenzene. For five of the chemicals studied (not bromobenzene) there is a very good correlation between the cytotoxic effects in Chlorella cells measured by the algal growth inhibition test, and the inhibition of photosystem II activity. The results suggest that one very important effect of these chemicals in Chlorella cells is the inhibition of photosynthetic metabolism by the blocking of photosystem II functionality. In the case of sodium monofluoroacetate, diethanolamine and chloroquine this inhibition seems to be related with the induction of high level of lipid peroxidation in cells that may alter the stability of photosystem II. The results obtained by both techniques supply information that can be used as a supplement to the growth inhibition test and allows a more complete assessment of the effects of

  20. Thermoluminescence as a complementary technique for the toxicological evaluation of chemicals in photosynthetic organisms

    International Nuclear Information System (INIS)

    Repetto, Guillermo; Zurita, Jorge L.; Roncel, Mercedes; Ortega, José M.

    2015-01-01

    Highlights: • There are very few toxicological applications of thermoluminescence. • It is a luminescence emission induced by heating the sample in the dark. • It is useful for study the photosystem II function and the level of lipid peroxidation. - Abstract: Thermoluminescence is a simple technique very useful for studying electron transfer reactions on photosystem II (standard thermoluminescence) or the level of lipid peroxidation in membranes (high temperature thermoluminescence) in photosynthetic organisms. Both techniques were used to investigate the effects produced on Chlorella vulgaris cells by six compounds: the chemical intermediates bromobenzene and diethanolamine, the antioxidant propyl gallate, the semiconductor indium nitrate, the pesticide sodium monofluoroacetate and the antimalarial drug chloroquine. Electron transfer activity of the photosystem II significantly decreased after the exposure of Chlorella cells to all the six chemicals used. Lipid peroxidation was slightly decreased by the antioxidant propyl gallate, not changed by indium nitrate and very potently stimulated by diethanolamine, chloroquine, sodium monofluoroacetate and bromobenzene. For five of the chemicals studied (not bromobenzene) there is a very good correlation between the cytotoxic effects in Chlorella cells measured by the algal growth inhibition test, and the inhibition of photosystem II activity. The results suggest that one very important effect of these chemicals in Chlorella cells is the inhibition of photosynthetic metabolism by the blocking of photosystem II functionality. In the case of sodium monofluoroacetate, diethanolamine and chloroquine this inhibition seems to be related with the induction of high level of lipid peroxidation in cells that may alter the stability of photosystem II. The results obtained by both techniques supply information that can be used as a supplement to the growth inhibition test and allows a more complete assessment of the effects of

  1. Thermally emissive sensing materials for chemical spectroscopy analysis

    Science.gov (United States)

    Poole, Zsolt; Ohodnicki, Paul R.

    2018-05-08

    A sensor using thermally emissive materials for chemical spectroscopy analysis includes an emissive material, wherein the emissive material includes the thermally emissive materials which emit electromagnetic radiation, wherein the electromagnetic radiation is modified due to chemical composition in an environment; and a detector adapted to detect the electromagnetic radiation, wherein the electromagnetic radiation is indicative of the chemical interaction changes and hence chemical composition and/or chemical composition changes of the environment. The emissive material can be utilized with an optical fiber sensor, with the optical fiber sensor operating without the emissive material probed with a light source external to the material.

  2. Real analysis modern techniques and their applications

    CERN Document Server

    Folland, Gerald B

    1999-01-01

    An in-depth look at real analysis and its applications-now expanded and revised.This new edition of the widely used analysis book continues to cover real analysis in greater detail and at a more advanced level than most books on the subject. Encompassing several subjects that underlie much of modern analysis, the book focuses on measure and integration theory, point set topology, and the basics of functional analysis. It illustrates the use of the general theories and introduces readers to other branches of analysis such as Fourier analysis, distribution theory, and probability theory.This edi

  3. Chemical and thermal analysis for characterisation of building materials

    International Nuclear Information System (INIS)

    Kumar, S.C.; Sudersanan, M.; Ravindran, P.V.; Kalekar, B.B.; Mathur, P.K.

    2000-01-01

    Cement and other construction materials are extensively used for the construction of shielding materials for nuclear and high energy radiations. The design and optimum utilisation of such materials need an accurate analysis of their chemical composition. The moisture content and presence of bound water and other volatile materials are also important. The use of thermal analysis supplements the data obtained by chemical analysis and enables a distinction of moisture and chemically bound water. It also enables an identification of the process leading to the loss on ignition. The work carried out on the analysis of sand, cement and other aggregate materials used for the preparation of concrete is described in the paper. (author)

  4. Techniques involving extreme environment, nondestructive techniques, computer methods in metals research, and data analysis

    International Nuclear Information System (INIS)

    Bunshah, R.F.

    1976-01-01

    A number of different techniques which range over several different aspects of materials research are covered in this volume. They are concerned with property evaluation of 4 0 K and below, surface characterization, coating techniques, techniques for the fabrication of composite materials, computer methods, data evaluation and analysis, statistical design of experiments and non-destructive test techniques. Topics covered in this part include internal friction measurements; nondestructive testing techniques; statistical design of experiments and regression analysis in metallurgical research; and measurement of surfaces of engineering materials

  5. Chemical Diversity, Origin, and Analysis of Phycotoxins

    DEFF Research Database (Denmark)

    Rasmussen, Silas Anselm; Andersen, Aaron John Christian; Andersen, Nikolaj Gedsted

    2016-01-01

    , yessotoxins, azaspiracids, brevetoxins, and pinnatoxins. Other toxins, such as ciguatoxins and maitotoxins, accumulate in fish, where, as is the case for the latter compounds, they can be metabolized to even more toxic metabolites. On the other hand, much less is known about the chemical nature of compounds...

  6. Application of functional analysis techniques to supervisory systems

    International Nuclear Information System (INIS)

    Lambert, Manuel; Riera, Bernard; Martel, Gregory

    1999-01-01

    The aim of this paper is to apply firstly two interesting functional analysis techniques for the design of supervisory systems for complex processes, and secondly to discuss the strength and the weaknesses of each of them. Two functional analysis techniques have been applied, SADT (Structured Analysis and Design Technique) and FAST (Functional Analysis System Technique) on a process, an example of a Water Supply Process Control (WSPC) system. These techniques allow a functional description of industrial processes. The paper briefly discusses the functions of a supervisory system and some advantages of the application of functional analysis for the design of a 'human' centered supervisory system. Then the basic principles of the two techniques applied on the WSPC system are presented. Finally, the different results obtained from the two techniques are discussed

  7. IMAGE ANALYSIS BASED ON EDGE DETECTION TECHNIQUES

    Institute of Scientific and Technical Information of China (English)

    纳瑟; 刘重庆

    2002-01-01

    A method that incorporates edge detection technique, Markov Random field (MRF), watershed segmentation and merging techniques was presented for performing image segmentation and edge detection tasks. It first applies edge detection technique to obtain a Difference In Strength (DIS) map. An initial segmented result is obtained based on K-means clustering technique and the minimum distance. Then the region process is modeled by MRF to obtain an image that contains different intensity regions. The gradient values are calculated and then the watershed technique is used. DIS calculation is used for each pixel to define all the edges (weak or strong) in the image. The DIS map is obtained. This help as priority knowledge to know the possibility of the region segmentation by the next step (MRF), which gives an image that has all the edges and regions information. In MRF model,gray level l, at pixel location i, in an image X, depends on the gray levels of neighboring pixels. The segmentation results are improved by using watershed algorithm. After all pixels of the segmented regions are processed, a map of primitive region with edges is generated. The edge map is obtained using a merge process based on averaged intensity mean values. A common edge detectors that work on (MRF) segmented image are used and the results are compared. The segmentation and edge detection result is one closed boundary per actual region in the image.

  8. MCNP perturbation technique for criticality analysis

    International Nuclear Information System (INIS)

    McKinney, G.W.; Iverson, J.L.

    1995-01-01

    The differential operator perturbation technique has been incorporated into the Monte Carlo N-Particle transport code MCNP and will become a standard feature of future releases. This feature includes first and/or second order terms of the Taylor Series expansion for response perturbations related to cross-section data (i.e., density, composition, etc.). Criticality analyses can benefit from this technique in that predicted changes in the track-length tally estimator of K eff may be obtained for multiple perturbations in a single run. A key advantage of this method is that a precise estimate of a small change in response (i.e., < 1%) is easily obtained. This technique can also offer acceptable accuracy, to within a few percent, for up to 20-30% changes in a response

  9. Data Analysis Techniques for Physical Scientists

    Science.gov (United States)

    Pruneau, Claude A.

    2017-10-01

    Preface; How to read this book; 1. The scientific method; Part I. Foundation in Probability and Statistics: 2. Probability; 3. Probability models; 4. Classical inference I: estimators; 5. Classical inference II: optimization; 6. Classical inference III: confidence intervals and statistical tests; 7. Bayesian inference; Part II. Measurement Techniques: 8. Basic measurements; 9. Event reconstruction; 10. Correlation functions; 11. The multiple facets of correlation functions; 12. Data correction methods; Part III. Simulation Techniques: 13. Monte Carlo methods; 14. Collision and detector modeling; List of references; Index.

  10. Surface analysis and techniques in biology

    CERN Document Server

    Smentkowski, Vincent S

    2014-01-01

    This book highlights state-of-the-art surface analytical instrumentation, advanced data analysis tools, and the use of complimentary surface analytical instrumentation to perform a complete analysis of biological systems.

  11. Avogadro: an advanced semantic chemical editor, visualization, and analysis platform.

    Science.gov (United States)

    Hanwell, Marcus D; Curtis, Donald E; Lonie, David C; Vandermeersch, Tim; Zurek, Eva; Hutchison, Geoffrey R

    2012-08-13

    The Avogadro project has developed an advanced molecule editor and visualizer designed for cross-platform use in computational chemistry, molecular modeling, bioinformatics, materials science, and related areas. It offers flexible, high quality rendering, and a powerful plugin architecture. Typical uses include building molecular structures, formatting input files, and analyzing output of a wide variety of computational chemistry packages. By using the CML file format as its native document type, Avogadro seeks to enhance the semantic accessibility of chemical data types. The work presented here details the Avogadro library, which is a framework providing a code library and application programming interface (API) with three-dimensional visualization capabilities; and has direct applications to research and education in the fields of chemistry, physics, materials science, and biology. The Avogadro application provides a rich graphical interface using dynamically loaded plugins through the library itself. The application and library can each be extended by implementing a plugin module in C++ or Python to explore different visualization techniques, build/manipulate molecular structures, and interact with other programs. We describe some example extensions, one which uses a genetic algorithm to find stable crystal structures, and one which interfaces with the PackMol program to create packed, solvated structures for molecular dynamics simulations. The 1.0 release series of Avogadro is the main focus of the results discussed here. Avogadro offers a semantic chemical builder and platform for visualization and analysis. For users, it offers an easy-to-use builder, integrated support for downloading from common databases such as PubChem and the Protein Data Bank, extracting chemical data from a wide variety of formats, including computational chemistry output, and native, semantic support for the CML file format. For developers, it can be easily extended via a powerful

  12. Heterogeneous chemical kinetics by modulated molecular beam mass spectrometry: limitations of technique

    International Nuclear Information System (INIS)

    Olander, D.R.

    1977-01-01

    The advantages and limitations of modulated molecular beam, mass spectrometry as applied to the study of heterogeneous chemical kinetics are reviewed. The process of deducing a model of the surface reaction from experimental data is illustrated by analysis of the hydrogen reduction of uranium dioxide

  13. Analysis of chemical constituents in Cistanche species.

    Science.gov (United States)

    Jiang, Yong; Tu, Peng-Fei

    2009-03-13

    Species of the genus of Cistanche (Rou Cong Rong in Chinese) are perennial parasite herbs, and are mainly distributed in arid lands and warm deserts. As a superior tonic for the treatment of kidney deficiency, impotence, female infertility, morbid leucorrhea, profuse metrorrhagia and senile constipation, Cistanche herbs earned the honor of "Ginseng of the desert". Recently, there has been increasing scientific attention on Herba Cistanche for its remarkable bioactivities including antioxidation, neuroprotection, and anti-aging. The chemical constituents of Cistanche plants mainly include volatile oils and non-volatile phenylethanoid glycosides (PhGs), iridoids, lignans, alditols, oligosaccharides and polysaccharides. Pharmacological studies show that PhGs are the main active components for curing kidney deficiency, antioxidation and neuroprotection; galactitol and oligosaccharides are the representatives for the treatment of senile constipation, while polysaccharides are responsible for improving body immunity. In this paper, the advances on the chemical constituents of Cistanche plants and their corresponding analyses are reviewed.

  14. Combining QSAR Modeling and Text-Mining Techniques to Link Chemical Structures and Carcinogenic Modes of Action.

    Science.gov (United States)

    Papamokos, George; Silins, Ilona

    2016-01-01

    There is an increasing need for new reliable non-animal based methods to predict and test toxicity of chemicals. Quantitative structure-activity relationship (QSAR), a computer-based method linking chemical structures with biological activities, is used in predictive toxicology. In this study, we tested the approach to combine QSAR data with literature profiles of carcinogenic modes of action automatically generated by a text-mining tool. The aim was to generate data patterns to identify associations between chemical structures and biological mechanisms related to carcinogenesis. Using these two methods, individually and combined, we evaluated 96 rat carcinogens of the hematopoietic system, liver, lung, and skin. We found that skin and lung rat carcinogens were mainly mutagenic, while the group of carcinogens affecting the hematopoietic system and the liver also included a large proportion of non-mutagens. The automatic literature analysis showed that mutagenicity was a frequently reported endpoint in the literature of these carcinogens, however, less common endpoints such as immunosuppression and hormonal receptor-mediated effects were also found in connection with some of the carcinogens, results of potential importance for certain target organs. The combined approach, using QSAR and text-mining techniques, could be useful for identifying more detailed information on biological mechanisms and the relation with chemical structures. The method can be particularly useful in increasing the understanding of structure and activity relationships for non-mutagens.

  15. Combining QSAR Modeling and Text-Mining Techniques to Link Chemical Structures and Carcinogenic Modes of Action

    Science.gov (United States)

    Papamokos, George; Silins, Ilona

    2016-01-01

    There is an increasing need for new reliable non-animal based methods to predict and test toxicity of chemicals. Quantitative structure-activity relationship (QSAR), a computer-based method linking chemical structures with biological activities, is used in predictive toxicology. In this study, we tested the approach to combine QSAR data with literature profiles of carcinogenic modes of action automatically generated by a text-mining tool. The aim was to generate data patterns to identify associations between chemical structures and biological mechanisms related to carcinogenesis. Using these two methods, individually and combined, we evaluated 96 rat carcinogens of the hematopoietic system, liver, lung, and skin. We found that skin and lung rat carcinogens were mainly mutagenic, while the group of carcinogens affecting the hematopoietic system and the liver also included a large proportion of non-mutagens. The automatic literature analysis showed that mutagenicity was a frequently reported endpoint in the literature of these carcinogens, however, less common endpoints such as immunosuppression and hormonal receptor-mediated effects were also found in connection with some of the carcinogens, results of potential importance for certain target organs. The combined approach, using QSAR and text-mining techniques, could be useful for identifying more detailed information on biological mechanisms and the relation with chemical structures. The method can be particularly useful in increasing the understanding of structure and activity relationships for non-mutagens. PMID:27625608

  16. ANALYSIS AND IDENTIFICATION SPIKING CHEMICAL COMPOUNDS RELATED TO CHEMICAL WEAPON CONVENTION IN UNKNOWN WATER SAMPLES USING GAS CHROMATOGRAPHY AND GAS CHROMATOGRAPHY ELECTRON IONIZATION MASS SPECTROMETRY

    Directory of Open Access Journals (Sweden)

    Harry Budiman

    2010-06-01

    Full Text Available The identification and analysis of chemical warfare agents and their degradation products is one of important component for the implementation of the convention. Nowadays, the analytical method for determination chemical warfare agent and their degradation products has been developing and improving. In order to get the sufficient analytical data as recommended by OPCW especially in Proficiency Testing, the spiking chemical compounds related to Chemical Weapon Convention in unknown water sample were determined using two different techniques such as gas chromatography and gas chromatography electron-impact ionization mass spectrometry. Neutral organic extraction, pH 11 organic extraction, cation exchanged-methylation, triethylamine/methanol-silylation were performed to extract the chemical warfare agents from the sample, before analyzing with gas chromatography. The identification of chemical warfare agents was carried out by comparing the mass spectrum of chemicals with mass spectrum reference from the OPCW Central Analytical Database (OCAD library while the retention indices calculation obtained from gas chromatography analysis was used to get the confirmation and supported data of  the chemical warfare agents. Diisopropyl methylphosphonate, 2,2-diphenyl-2-hydroacetic acid and 3-quinuclidinol were found in unknown water sample. Those chemicals were classified in schedule 2 as precursor or reactant of chemical weapons compound in schedule list of Chemical Weapon Convention.   Keywords: gas chromatography, mass spectrometry, retention indices, OCAD library, chemical warfare agents

  17. Role of quantitative chemical shift magnetic resonance imaging and chemical shift subtraction technique in discriminating adenomatous from non adenomatous adrenal solid lesions

    Directory of Open Access Journals (Sweden)

    Ahmed H. Afifi

    2017-03-01

    Conclusion: The signal intensity index and adrenal to spleen ratio are the most reliable quantitative chemical shift MRI methods in differentiation of adrenal adenomas from other non-adenomatous adrenal solid lesions. Chemical shift subtraction MRI is a recent technique that gives highly confident discrimination between two categories of pathology without using of any reference organ.

  18. Metabolomic analysis using porcine skin: a pilot study of analytical techniques

    OpenAIRE

    Wu, Julie; Fiehn, Oliver; Armstrong, April W

    2014-01-01

    Background: Metabolic byproducts serve as indicators of the chemical processes and can provide valuable information on pathogenesis by measuring the amplified output. Standardized techniques for metabolome extraction of skin samples serve as a critical foundation to this field but have not been developed. Objectives: We sought to determine the optimal cell lysage techniques for skin sample preparation and to compare GC-TOF-MS and UHPLC-QTOF-MS for metabolomic analysis. ...

  19. Chemical-Free Technique to Study the Ultrastructure of Primary Cilium.

    Science.gov (United States)

    Mohieldin, Ashraf M; AbouAlaiwi, Wissam A; Gao, Min; Nauli, Surya M

    2015-11-02

    A primary cilium is a hair-like structure with a width of approximately 200 nm. Over the past few decades, the main challenge in the study of the ultrastructure of cilia has been the high sensitivity of cilia to chemical fixation, which is required for many imaging techniques. In this report, we demonstrate a combined high-pressure freezing (HPF) and freeze-fracture transmission electron microscopy (FFTEM) technique to examine the ultrastructure of a cilium. Our objective is to develop an optimal high-resolution imaging approach that preserves cilia structures in their best natural form without alteration of cilia morphology by chemical fixation interference. Our results showed that a cilium has a swelling-like structure (termed bulb), which was previously considered a fixation artifact. The intramembrane particles observed via HPF/FFTEM indicated the presence of integral membrane proteins and soluble matrix proteins along the ciliary bulb, which is part of an integral structure within the ciliary membrane. We propose that HPF/FFTEM is an important and more suitable chemical-free method to study the ultrastructure of primary cilia.

  20. The fission-track analysis: An alternative technique for provenance studies of prehistoric obsidian artefacts

    CERN Document Server

    Bellot-Gurlet, L; Dorighel, O; Oddone, M; Poupeau, G; Yegingil, Z

    1999-01-01

    Comparison of fission-track parameters - age and track densities - is an alternative tool for correlating obsidian artefacts with their potential natural sources. This method was applied by different fission-track groups in various regions and results were compared with those obtained using the more popular provenance identification techniques based on chemical composition studies. Hundreds of analyses prove that fission-track dating is a complementary technique which turns out to be very useful, specially when the chemical composition does not fully discriminate different sources. Archaeologically significant results were obtained applying the fission-track analysis in various regions of earth.

  1. The fission-track analysis: An alternative technique for provenance studies of prehistoric obsidian artefacts

    International Nuclear Information System (INIS)

    Bellot-Gurlet, L.; Bigazzi, G.; Dorighel, O.; Oddone, M.; Poupeau, G.; Yegingil, Z.

    1999-01-01

    Comparison of fission-track parameters - age and track densities - is an alternative tool for correlating obsidian artefacts with their potential natural sources. This method was applied by different fission-track groups in various regions and results were compared with those obtained using the more popular provenance identification techniques based on chemical composition studies. Hundreds of analyses prove that fission-track dating is a complementary technique which turns out to be very useful, specially when the chemical composition does not fully discriminate different sources. Archaeologically significant results were obtained applying the fission-track analysis in various regions of earth

  2. Survey of immunoassay techniques for biological analysis

    International Nuclear Information System (INIS)

    Burtis, C.A.

    1986-10-01

    Immunoassay is a very specific, sensitive, and widely applicable analytical technique. Recent advances in genetic engineering have led to the development of monoclonal antibodies which further improves the specificity of immunoassays. Originally, radioisotopes were used to label the antigens and antibodies used in immunoassays. However, in the last decade, numerous types of immunoassays have been developed which utilize enzymes and fluorescent dyes as labels. Given the technical, safety, health, and disposal problems associated with using radioisotopes, immunoassays that utilize the enzyme and fluorescent labels are rapidly replacing those using radioisotope labels. These newer techniques are as sensitive, are easily automated, have stable reagents, and do not have a disposal problem. 6 refs., 1 fig., 2 tabs

  3. Chemically intuited, large-scale screening of MOFs by machine learning techniques

    Science.gov (United States)

    Borboudakis, Giorgos; Stergiannakos, Taxiarchis; Frysali, Maria; Klontzas, Emmanuel; Tsamardinos, Ioannis; Froudakis, George E.

    2017-10-01

    A novel computational methodology for large-scale screening of MOFs is applied to gas storage with the use of machine learning technologies. This approach is a promising trade-off between the accuracy of ab initio methods and the speed of classical approaches, strategically combined with chemical intuition. The results demonstrate that the chemical properties of MOFs are indeed predictable (stochastically, not deterministically) using machine learning methods and automated analysis protocols, with the accuracy of predictions increasing with sample size. Our initial results indicate that this methodology is promising to apply not only to gas storage in MOFs but in many other material science projects.

  4. Solubilization of advanced ceramic materials controlled by chemical analysis by means of atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Amarante Junior, A.

    1992-01-01

    This paper purpose is to show the techniques used in chemical analysis laboratory at Escola SENAI Mario Amato in the ceramic nucleus for opening and solubilization of Advanced Ceramic materials, where the elements in its majority are determined for atomic absorption spectroscopy. (author)

  5. Direct chemical analysis of frozen ice cores by UV-laser ablation ICPMS

    DEFF Research Database (Denmark)

    Müller, Wolfgang; Shelley, J. Michael G.; Rasmussen, Sune Olander

    2011-01-01

    Cryo-cell UV-LA-ICPMS is a new technique for direct chemical analysis of frozen ice cores at high spatial resolution (dust records and annual layer signatures at unprecedented spatial/time resolution. Uniquely......, the location of cation impurities relative to grain boundaries in recrystallized ice can be assessed....

  6. Data analysis techniques for gravitational wave observations

    Indian Academy of Sciences (India)

    Astrophysical sources of gravitational waves fall broadly into three categories: (i) transient and bursts, (ii) periodic or continuous wave and (iii) stochastic. Each type of source requires a different type of data analysis strategy. In this talk various data analysis strategies will be reviewed. Optimal filtering is used for extracting ...

  7. Chemical considerations in severe accident analysis

    International Nuclear Information System (INIS)

    Malinauskas, A.P.; Kress, T.S.

    1988-01-01

    The Reactor Safety Study presented the first systematic attempt to include fission product physicochemical effects in the determination of expected consequences of hypothetical nuclear reactor power plant accidents. At the time, however, the data base was sparse, and the treatment of fission product behavior was not entirely consistent or accurate. Considerable research has since been performed to identify and understand chemical phenomena that can occur in the course of a nuclear reactor accident, and how these phenomena affect fission product behavior. In this report, the current status of our understanding of the chemistry of fission products in severe core damage accidents is summarized and contrasted with that of the Reactor Safety Study

  8. Study of chemical cleaning technique for removing sludge in secondary side of PWR SG

    International Nuclear Information System (INIS)

    Zhang Mengqin; Zhang Shufeng; Pan Qingchun; Yu Jinghua; Hou Shufeng

    1993-12-01

    The effect of components, concentration, pH, temperature, cleaning time and flowrate of chemical cleaning solvent made from EDTA mainly on Fe 3 O 4 solubility and corrosion rate of A3 carbon steel, S271 low alloy steel and 800 alloy are introduced. A small chemical cleaning test loop (30L) was built to study the cleaning technique. The effect of residue of chemical cleaning solvent on anti-corrosion performance of materials has been studied under the simulation condition of PWR (pressure water reactor) SG (steam generator) secondary side. The results show that the chemical solvent (pH = 7, 10% EDTA, 1% assistance solvent and 0.25% inhibitor A) can dissolve Fe 3 O 4 18 ∼23 g/L under the conditions of 93 +- 5 degree C, 8 hours and 112 r/min (1.8 ∼ 2.0 t/h). The corrosion rate of material is low. When the residue of EDTA is less than 0.01% there is no impact on the anti-corrosion performance of materials in PWR SG secondary side at normal operation condition (260 +- 5 degree C)

  9. Characterization of CuS nanocrystalline thin films synthesized by chemical bath deposition and dip coating techniques

    International Nuclear Information System (INIS)

    Chaki, Sunil H.; Deshpande, M.P.; Tailor, Jiten P.

    2014-01-01

    CuS thin films were synthesized by chemical bath deposition and dip coating techniques at ambient temperature. The energy dispersive analysis of X-rays of the thin films confirmed that both the as synthesized thin films are stoichiometric. The X-ray diffraction of the chemical bath deposited and dip coating deposited thin films showed that the films possess hexagonal structure having lattice parameters, a = b = 3.79 A and c = 16.34 A. The crystallite sizes determined from the X-ray diffraction data using Scherrer's formula for the chemical bath deposition and dip coating deposition thin films came out to be nearly 11 nm and 13 nm, respectively. The optical microscopy of the as deposited thin films surfaces showed that the substrates are well covered in both the deposited films. The scanning electron microscopy of the thin films clearly showed that in chemical bath deposited thin films the grain size varies from few μm to nm, while in dip coating deposited films the grain size ranges in nm. The optical bandgap determined from the optical absorbance spectrum analysis showed, chemical bath deposited thin films possess direct bandgap of 2.2 eV and indirect bandgap of 1.8 eV. In the case of dip coating deposited thin films, the direct bandgap is 2.5 eV and indirect bandgap is 1.9 eV. The d.c. electrical resistivity variation with temperature for both the deposited films showed that the resistivity decreases with temperature thus confirming the semiconducting nature. The thermoelectric power variations with temperature and the room temperature Hall Effect study of both the synthesized CuS thin films showed them to be of p-type conductivity. The obtained results are discussed in details. - Highlights: • CuS thin films were synthesized by chemical bath deposition and dip coating techniques. • The films possessed hexagonal structure. • The optical absorption showed that the films had direct and indirect bandgap. • Study of electrical transport properties

  10. Visualization techniques for malware behavior analysis

    Science.gov (United States)

    Grégio, André R. A.; Santos, Rafael D. C.

    2011-06-01

    Malware spread via Internet is a great security threat, so studying their behavior is important to identify and classify them. Using SSDT hooking we can obtain malware behavior by running it in a controlled environment and capturing interactions with the target operating system regarding file, process, registry, network and mutex activities. This generates a chain of events that can be used to compare them with other known malware. In this paper we present a simple approach to convert malware behavior into activity graphs and show some visualization techniques that can be used to analyze malware behavior, individually or grouped.

  11. INVERSE FILTERING TECHNIQUES IN SPEECH ANALYSIS

    African Journals Online (AJOL)

    Dr Obe

    domain or in the frequency domain. However their .... computer to speech analysis led to important elaborations ... tool for the estimation of formant trajectory (10), ... prediction Linear prediction In effect determines the filter .... Radio Res. Lab.

  12. Techniques for Intelligence Analysis of Networks

    National Research Council Canada - National Science Library

    Cares, Jeffrey R

    2005-01-01

    ...) there are significant intelligence analysis manifestations of these properties; and (4) a more satisfying theory of Networked Competition than currently exists for NCW/NCO is emerging from this research...

  13. The Network Protocol Analysis Technique in Snort

    Science.gov (United States)

    Wu, Qing-Xiu

    Network protocol analysis is a network sniffer to capture data for further analysis and understanding of the technical means necessary packets. Network sniffing is intercepted by packet assembly binary format of the original message content. In order to obtain the information contained. Required based on TCP / IP protocol stack protocol specification. Again to restore the data packets at protocol format and content in each protocol layer. Actual data transferred, as well as the application tier.

  14. Analysis of chemical constituents in medicinal plants of selected ...

    African Journals Online (AJOL)

    Analysis of chemical constituents in medicinal plants of selected districts of Pakhtoonkhwa, Pakistan. I Hussain, R Ullah, J Khan, N Khan, M Zahoor, N Ullah, MuR Khattak, FA Khan, A Baseer, M Khurram ...

  15. Chemical composition of a yellowish rainfall by the application of PIXE and micro-PIXE technique

    International Nuclear Information System (INIS)

    Ma, C.-J.

    2006-01-01

    Information of the chemical properties of rain fallen during the Asian dust (AD) event will help us to better understand the wet scavenging processes of dust particles. In this study, the chemical characteristics of rainwater and individual raindrops fallen during the AD storm have been investigated. The yellowish rainwater and individual raindrops were collected simultaneously in Kyoto, Japan on 7 April 2001. Particle induced X-ray emission (PIXE) was employed in the determination of chemical properties of soluble and insoluble fractions of rainwater. In addition, micro-PIXE was applied to the chemical analysis of residual materials retained in the initial individual raindrops. The pH level of yellowish rainwater was measured around 6.7. In compliance with the general expectation, major components in rainwater were of soil-origin such as Si, K, Ca, Ti and Fe. These soil-related components contributed to as much as 92% of total elemental composition in both soluble and insoluble fractions. By scanning a micro-beam, the residual particle cluster in individual raindrops was reconstructed in terms of an elemental map. This visualized elemental map in fact enabled us not only to estimate the chemical mixing state of raindrop residual particles but also to presume the wet scavenging of dust particles by rainfall

  16. Statistic analysis of grouping in evaluation of the behavior of stable chemical elements and physical-chemical parameters in effluent from uranium mining

    International Nuclear Information System (INIS)

    Pereira, Wagner de S.

    2013-01-01

    The Ore Treatment Unit (UTM) is a uranium mine off. The statistical analysis of clustering was used to evaluate the behavior of stable chemical elements and physico-chemical variables in their effluents. The use of cluster analysis proved effective in the evaluation, allowing to identify groups of chemical elements in physico-chemical variables and group analyzes (element and variables ). As a result, we can say, based on the analysis of the data, a strong link between Ca and Mg and between Al and TR 2 O 3 (rare earth oxides) in the UTM effluents. The SO 4 was also identified as strongly linked to total solids and dissolved and these linked to electrical conductivity. Other associations existed, but were not as strongly linked. Additional collections for seasonal evaluation are required so that assessments can be confirmed. Additional statistics analysis (ordination techniques) should be used to help identify the origins of the groups identified in this analysis. (author)

  17. Uncertainty analysis technique for OMEGA Dante measurementsa)

    Science.gov (United States)

    May, M. J.; Widmann, K.; Sorce, C.; Park, H.-S.; Schneider, M.

    2010-10-01

    The Dante is an 18 channel x-ray filtered diode array which records the spectrally and temporally resolved radiation flux from various targets (e.g., hohlraums, etc.) at x-ray energies between 50 eV and 10 keV. It is a main diagnostic installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The absolute flux is determined from the photometric calibration of the x-ray diodes, filters and mirrors, and an unfold algorithm. Understanding the errors on this absolute measurement is critical for understanding hohlraum energetic physics. We present a new method for quantifying the uncertainties on the determined flux using a Monte Carlo parameter variation technique. This technique combines the uncertainties in both the unfold algorithm and the error from the absolute calibration of each channel into a one sigma Gaussian error function. One thousand test voltage sets are created using these error functions and processed by the unfold algorithm to produce individual spectra and fluxes. Statistical methods are applied to the resultant set of fluxes to estimate error bars on the measurements.

  18. Uncertainty analysis technique for OMEGA Dante measurements

    International Nuclear Information System (INIS)

    May, M. J.; Widmann, K.; Sorce, C.; Park, H.-S.; Schneider, M.

    2010-01-01

    The Dante is an 18 channel x-ray filtered diode array which records the spectrally and temporally resolved radiation flux from various targets (e.g., hohlraums, etc.) at x-ray energies between 50 eV and 10 keV. It is a main diagnostic installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The absolute flux is determined from the photometric calibration of the x-ray diodes, filters and mirrors, and an unfold algorithm. Understanding the errors on this absolute measurement is critical for understanding hohlraum energetic physics. We present a new method for quantifying the uncertainties on the determined flux using a Monte Carlo parameter variation technique. This technique combines the uncertainties in both the unfold algorithm and the error from the absolute calibration of each channel into a one sigma Gaussian error function. One thousand test voltage sets are created using these error functions and processed by the unfold algorithm to produce individual spectra and fluxes. Statistical methods are applied to the resultant set of fluxes to estimate error bars on the measurements.

  19. Uncertainty Analysis Technique for OMEGA Dante Measurements

    International Nuclear Information System (INIS)

    May, M.J.; Widmann, K.; Sorce, C.; Park, H.; Schneider, M.

    2010-01-01

    The Dante is an 18 channel X-ray filtered diode array which records the spectrally and temporally resolved radiation flux from various targets (e.g. hohlraums, etc.) at X-ray energies between 50 eV to 10 keV. It is a main diagnostics installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The absolute flux is determined from the photometric calibration of the X-ray diodes, filters and mirrors and an unfold algorithm. Understanding the errors on this absolute measurement is critical for understanding hohlraum energetic physics. We present a new method for quantifying the uncertainties on the determined flux using a Monte-Carlo parameter variation technique. This technique combines the uncertainties in both the unfold algorithm and the error from the absolute calibration of each channel into a one sigma Gaussian error function. One thousand test voltage sets are created using these error functions and processed by the unfold algorithm to produce individual spectra and fluxes. Statistical methods are applied to the resultant set of fluxes to estimate error bars on the measurements.

  20. Direct synthesis of nanocrystalline oxide powders by wet-chemical techniques

    Directory of Open Access Journals (Sweden)

    Vladimir V. Srdić

    2010-09-01

    Full Text Available In a recent period there is a great need for increasing the knowledge of tailoring the innovative procedures for the synthesis of electroceramic nanopowders and materials with improved quality for specific application. In order to produce electroceramics with desirable microstructure and properties, synthesis of stoichiometric, ultra-fine and agglomerate free powders with narrow size distributions is one of the most important steps. Within this scope, in the present paper we summarize our recent results on direct synthesis of some important perovskites and ferrites nanopowders by wet-chemical techniques.

  1. Chemical stability of fluorine-containing coatings of cold drying for radiation - protection technique articles

    International Nuclear Information System (INIS)

    Shigorina, I.I.; Zvyagintseva, N.V.; Egorov, B.N.

    1977-01-01

    The chemical stability of fluorolon coatings, which are not subjected to heat treatment or hot drying during application, has been studied. The test for layer life-time has been performed by submerging specimens in agressive medium. The time for one upper removable layer to fail under steady action of agressive liquid is found to be: > 12 months at 20 deg C, 6-9 months at 40 deg C; at 60 deg C the time of layer stability depends upon medium: 1 month for nitric, 2 months for acetic, 2-3 months for sulphuric and hydrochloric acid. The coatings are recommended for practical application in radiation-protective technique

  2. ZnO nanowall network grown by chemical vapor deposition technique

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, Amrita, E-mail: but.then.perhaps@gmail.com; Dhar, Subhabrata [Department of Physics, Indian Institute of Technology Bombay, Powai, Mumbai-400076 (India)

    2015-06-24

    Network of wedge shaped ZnO nanowalls are grown on c-sapphire by Chemical Vapor Deposition (CVD) technique. Structural studies using x-ray diffraction show much better crystallinity in the nanowall sample as compared to the continuous film. Moreover, the defect related broad green luminescence is found to be suppressed in the nanowall sample. The low temperature photoluminescence study also suggests the quantum confinement of carriers in nanowall sample. Electrical studies performed on the nanowalls show higher conductivity, which has been explained in terms of the reduction of scattering cross-section as a result of 1D quantum confinement of carriers on the tip of the nanowalls.

  3. Reliability analysis techniques for the design engineer

    International Nuclear Information System (INIS)

    Corran, E.R.; Witt, H.H.

    1980-01-01

    A fault tree analysis package is described that eliminates most of the housekeeping tasks involved in proceeding from the initial construction of a fault tree to the final stage of presenting a reliability analysis in a safety report. It is suitable for designers with relatively little training in reliability analysis and computer operation. Users can rapidly investigate the reliability implications of various options at the design stage, and evolve a system which meets specified reliability objectives. Later independent review is thus unlikely to reveal major shortcomings necessitating modification and projects delays. The package operates interactively allowing the user to concentrate on the creative task of developing the system fault tree, which may be modified and displayed graphically. For preliminary analysis system data can be derived automatically from a generic data bank. As the analysis procedes improved estimates of critical failure rates and test and maintenance schedules can be inserted. The computations are standard, - identification of minimal cut-sets, estimation of reliability parameters, and ranking of the effect of the individual component failure modes and system failure modes on these parameters. The user can vary the fault trees and data on-line, and print selected data for preferred systems in a form suitable for inclusion in safety reports. A case history is given - that of HIFAR containment isolation system. (author)

  4. New radiochemistry techniques monograph: open-quotes Ultrafast chemical separationsclose quotes

    International Nuclear Information System (INIS)

    Ypsilanti, M.I.; Meyer, R.A.; Rengan, K.

    1992-01-01

    Study of decay characteristics of short-lived nuclides has fascinated nuclear chemists ever since the discovery of radioactivity. In the last two decades nuclides with half-lives in the range of several seconds to several tens of seconds have been explored. In addition to manual procedures, several automatic batch (autobatch) as well as continuous separation procedures have been developed for the study of these nuclides. The first part of the radiochemical techniques monograph entitled open-quotes Ultrafast Chemical Separationsclose quotes reviews the techniques used in fast separations. A collection of known fast procedures, arranged according to the name of the element, is presented in the second part. A total of 316 procedures for 75 elements are included

  5. Physical and chemical properties of gels. Application to protein nucleation control in the gel acupuncture technique

    Science.gov (United States)

    Moreno, Abel; Juárez-Martínez, Gabriela; Hernández-Pérez, Tomás; Batina, Nikola; Mundo, Manuel; McPherson, Alexander

    1999-09-01

    In this work, we present a new approach using analytical and optical techniques in order to determine the physical and chemical properties of silica gel, as well as the measurement of the pore size in the network of the gel by scanning electron microscopy. The gel acupuncture technique developed by García-Ruiz et al. (Mater. Res. Bull 28 (1993) 541) García-Ruiz and Moreno (Acta Crystallogr. D 50 (1994) 484) was used throughout the history of crystal growth. Several experiments were done in order to evaluate the nucleation control of model proteins (thaumatin I from Thaumatococcus daniellii, lysozyme from hen egg white and catalase from bovine liver) by the porous network of the gel. Finally, it is shown how the number and the size of the crystals obtained inside X-ray capillaries is controlled by the size of the porous structure of the gel.

  6. Metallographic examination of TD-nickel base alloys. [thermal and chemical etching technique evaluation

    Science.gov (United States)

    Kane, R. D.; Petrovic, J. J.; Ebert, L. J.

    1975-01-01

    Techniques are evaluated for chemical, electrochemical, and thermal etching of thoria dispersed (TD) nickel alloys. An electrochemical etch is described which yielded good results only for large grain sizes of TD-nickel. Two types of thermal etches are assessed for TD-nickel: an oxidation etch and vacuum annealing of a polished specimen to produce an etch. It is shown that the first etch was somewhat dependent on sample orientation with respect to the processing direction, the second technique was not sensitive to specimen orientation or grain size, and neither method appear to alter the innate grain structure when the materials were fully annealed prior to etching. An electrochemical etch is described which was used to observe the microstructures in TD-NiCr, and a thermal-oxidation etch is shown to produce better detail of grain boundaries and to have excellent etching behavior over the entire range of grain sizes of the sample.

  7. Generation and analysis of chemical compound libraries

    Science.gov (United States)

    Gregoire, John M.; Jin, Jian; Kan, Kevin S.; Marcin, Martin R.; Mitrovic, Slobodan; Newhouse, Paul F.; Suram, Santosh K.; Xiang, Chengxiang; Zhou, Lan

    2017-10-03

    Various samples are generated on a substrate. The samples each includes or consists of one or more analytes. In some instances, the samples are generated through the use of gels or through vapor deposition techniques. The samples are used in an instrument for screening large numbers of analytes by locating the samples between a working electrode and a counter electrode assembly. The instrument also includes one or more light sources for illuminating each of the samples. The instrument is configured to measure the photocurrent formed through a sample as a result of the illumination of the sample.

  8. Nucelar reactor seismic safety analysis techniques

    International Nuclear Information System (INIS)

    Cummings, G.E.; Wells, J.E.; Lewis, L.C.

    1979-04-01

    In order to provide insights into the seismic safety requirements for nuclear power plants, a probabilistic based systems model and computational procedure have been developed. This model and computational procedure will be used to identify where data and modeling uncertainties need to be decreased by studying the effect of these uncertainties on the probability of radioactive release and the probability of failure of various structures, systems, and components. From the estimates of failure and release probabilities and their uncertainties the most sensitive steps in the seismic methodologies can be identified. In addition, the procedure will measure the uncertainty due to random occurrences, e.g. seismic event probabilities, material property variability, etc. The paper discusses the elements of this systems model and computational procedure, the event-tree/fault-tree development, and the statistical techniques to be employed

  9. Analysis of Jordanian Cigarettes Using XRF Techniques

    International Nuclear Information System (INIS)

    Kullab, M.; Ismail, A.; AL-kofahi, M.

    2002-01-01

    Sixteen brands of Jordanian cigarettes were analyzed using X-ray Fluorescence (XRF) techniques. These cigarettes were found to contain the elements: Si, S, Cl, K, Ca, P, Ti, Mn, Fe, Cu, Zn, Br.Rb and Sr. The major elements with concentrations of more than 1% by weight were Cl,K and Ca. The elements with minor concentrations, Between 0.1 and 1% by weight, were Si, S and P. The trace elements with concentrations below 0.1% by weight were Ti, Mn, Fe, Cu, Zn, Br, Rb and Sr. The toxicity of some trace elements, like Br, Rb, and Sr, which are present in some brands of Jordanian cigarettes, is discussed. (Author's) 24 refs., 1 tab., 1 fig

  10. Decentralized control using compositional analysis techniques

    NARCIS (Netherlands)

    Kerber, F.; van der Schaft, A. J.

    2011-01-01

    Decentralized control strategies aim at achieving a global control target by means of distributed local controllers acting on individual subsystems of the overall plant. In this sense, decentralized control is a dual problem to compositional analysis where a global verification task is decomposed

  11. Techniques and Applications of Urban Data Analysis

    KAUST Repository

    AlHalawani, Sawsan

    2016-01-01

    Digitization and characterization of urban spaces are essential components as we move to an ever-growing ’always connected’ world. Accurate analysis of such digital urban spaces has become more important as we continue to get spatial and social

  12. Evaluating Dynamic Analysis Techniques for Program Comprehension

    NARCIS (Netherlands)

    Cornelissen, S.G.M.

    2009-01-01

    Program comprehension is an essential part of software development and software maintenance, as software must be sufficiently understood before it can be properly modified. One of the common approaches in getting to understand a program is the study of its execution, also known as dynamic analysis.

  13. COLLABORATIVE TRIAL AND QUALITY CONTROL IN CHEMICAL ANALYSIS

    Directory of Open Access Journals (Sweden)

    Narsito Narsito

    2010-06-01

    Full Text Available Abstract                                                             This paper deals with some practical problems related to the quality of analytical chemical data usually met in practice. Special attention is given to the topic of quality control in analytical chemistry, since analytical data is one of the primary information from which some important scientifically based decision are to be made. The present paper starts with brief description on some fundamental aspects associated with quality of analytical data, such as sources of variation of analytical data, criteria for quality of analytical method, quality assurance in chemical analysis. The assessment of quality parameter for analytical method like the use of standard materials as well as standard methods is given. Concerning with the quality control of analytical data, the use of several techniques, such as control samples and control charts, in monitoring analytical data in quality control program are described qualitatively.  In the final part of this paper, some important remarks for the preparation of collaborative trials, including the evaluation of accuracy and reproducibility of analytical method are also given Keywords: collaborative trials, quality control, analytical data Abstract                                                             This paper deals with some practical problems related to the quality of analytical chemical data usually met in practice. Special attention is given to the topic of quality control in analytical chemistry, since analytical data is one of the primary information from which some important scientifically based decision are to be made. The present paper starts with brief description on some fundamental aspects associated with quality of analytical data, such as sources of variation of analytical data, criteria for quality of

  14. 10th Australian conference on nuclear techniques of analysis. Proceedings

    International Nuclear Information System (INIS)

    1998-01-01

    These proceedings contains abstracts and extended abstracts of 80 lectures and posters presented at the 10th Australian conference on nuclear techniques of analysis hosted by the Australian National University in Canberra, Australia from 24-26 of November 1997. The conference was divided into sessions on the following topics : ion beam analysis and its applications; surface science; novel nuclear techniques of analysis, characterization of thin films, electronic and optoelectronic material formed by ion implantation, nanometre science and technology, plasma science and technology. A special session was dedicated to new nuclear techniques of analysis, future trends and developments. Separate abstracts were prepared for the individual presentation included in this volume

  15. 10th Australian conference on nuclear techniques of analysis. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-06-01

    These proceedings contains abstracts and extended abstracts of 80 lectures and posters presented at the 10th Australian conference on nuclear techniques of analysis hosted by the Australian National University in Canberra, Australia from 24-26 of November 1997. The conference was divided into sessions on the following topics : ion beam analysis and its applications; surface science; novel nuclear techniques of analysis, characterization of thin films, electronic and optoelectronic material formed by ion implantation, nanometre science and technology, plasma science and technology. A special session was dedicated to new nuclear techniques of analysis, future trends and developments. Separate abstracts were prepared for the individual presentation included in this volume.

  16. A methodological comparison of customer service analysis techniques

    Science.gov (United States)

    James Absher; Alan Graefe; Robert Burns

    2003-01-01

    Techniques used to analyze customer service data need to be studied. Two primary analysis protocols, importance-performance analysis (IP) and gap score analysis (GA), are compared in a side-by-side comparison using data from two major customer service research projects. A central concern is what, if any, conclusion might be different due solely to the analysis...

  17. Nuclear techniques for analysis of environmental samples

    International Nuclear Information System (INIS)

    1986-12-01

    The main purposes of this meeting were to establish the state-of-the-art in the field, to identify new research and development that is required to provide an adequate framework for analysis of environmental samples and to assess needs and possibilities for international cooperation in problem areas. This technical report was prepared on the subject based on the contributions made by the participants. A separate abstract was prepared for each of the 9 papers

  18. Analysis of blood spots for polyfluoroalkyl chemicals

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Kayoko; Wanigatunga, Amal A.; Needham, Larry L. [Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA (United States); Calafat, Antonia M., E-mail: acalafat@cdc.gov [Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA (United States)

    2009-12-10

    Polyfluoroalkyl chemicals (PFCs) have been detected in humans, in the environment, and in ecosystems around the world. The potential for developmental and reproductive toxicities of some PFCs is of concern especially to children's health. In the United States, a sample of a baby's blood, called a 'dried blood spot' (DBS), is obtained from a heel stick within 48 h of a child's birth. DBS could be useful for assessing prenatal exposure to PFCs. We developed a method based on online solid phase extraction coupled with high performance liquid chromatography-isotope dilution tandem mass spectrometry for measuring four PFCs in DBS, perfluorooctane sulfonate (PFOS), perfluorohexane sulfonate, perfluorooctanoate (PFOA), and perfluorononanoate. The analytical limits of detection using one whole DBS ({approx}75 {mu}L of blood) were <0.5 ng mL{sup -1}. To validate the method, we analyzed 98 DBS collected in May 2007 in the United States. PFOS and PFOA were detected in all DBS at concentrations in the low ng mL{sup -1} range. These data suggest that DBS may be a suitable matrix for assessing perinatal exposure to PFCs, but additional information related to sampling and specimen storage is needed to demonstrate the utility of these measures for assessing exposure.

  19. Application of activation techniques to biological analysis

    International Nuclear Information System (INIS)

    Bowen, H.J.M.

    1981-01-01

    Applications of activation analysis in the biological sciences are reviewed for the period of 1970 to 1979. The stages and characteristics of activation analysis are described, and its advantages and disadvantages enumerated. Most applications involve activation by thermal neutrons followed by either radiochemical or instrumental determination. Relatively little use has been made of activation by fast neutrons, photons, or charged particles. In vivo analyses are included, but those based on prompt gamma or x-ray emission are not. Major applications include studies of reference materials, and the elemental analysis of plants, marine biota, animal and human tissues, diets, and excreta. Relatively little use of it has been made in biochemistry, microbiology, and entomology, but it has become important in toxicology and environmental science. The elements most often determined are Ag, As, Au, Br, Ca, Cd, Cl, Co, Cr, Cs, Cu, Fe, Hg, I, K, Mn, Mo, Na, Rb, Sb, Sc, Se, and Zn, while few or no determinations of B, Be, Bi, Ga, Gd, Ge, H, In, Ir, Li, Nd, Os, Pd, Pr, Pt, Re, Rh, Ru, Te, Tl, or Y have been made in biological materials

  20. Bottom-Up, Wet Chemical Technique for the Continuous Synthesis of Inorganic Nanoparticles

    Directory of Open Access Journals (Sweden)

    Annika Betke

    2014-01-01

    Full Text Available Continuous wet chemical approaches for the production of inorganic nanoparticles are important for large scale production of nanoparticles. Here we describe a bottom-up, wet chemical method applying a microjet reactor. This technique allows the separation between nucleation and growth in a continuous reactor environment. Zinc oxide (ZnO, magnetite (Fe3O4, as well as brushite (CaHPO4·2H2O, particles with a small particle size distribution can be obtained continuously by using the rapid mixing of two precursor solutions and the fast removal of the nuclei from the reaction environment. The final particles were characterized by FT-IR, TGA, DLS, XRD and SEM techniques. Systematic studies on the influence of the different process parameters, such as flow rate and process temperature, show that the particle size can be influenced. Zinc oxide was obtained with particle sizes between 44 nm and 102 nm. The obtained magnetite particles have particle sizes in the range of 46 nm to 132 nm. Brushite behaves differently; the obtained particles were shaped like small plates with edge lengths between 100 nm and 500 nm.

  1. Nanostructured PLD-grown gadolinia doped ceria: Chemical and structural characterization by transmission electron microscopy techniques

    DEFF Research Database (Denmark)

    Rodrigo, Katarzyna Agnieszka; Wang, Hsiang-Jen; Heiroth, Sebastian

    2011-01-01

    The morphology as well as the spatially resolved elemental and chemical characterization of 10 mol% gadolinia doped ceria (CGO10) structures prepared by pulsed laser deposition (PLD) technique are investigated by scanning transmission electron microscopy accompanied with electron energy loss spec......, indicate apparent variation of the ceria valence state across and along the film. No element segregation to the grain boundaries is detected. These results are discussed in the context of solid oxide fuel cell applications.......The morphology as well as the spatially resolved elemental and chemical characterization of 10 mol% gadolinia doped ceria (CGO10) structures prepared by pulsed laser deposition (PLD) technique are investigated by scanning transmission electron microscopy accompanied with electron energy loss...... spectroscopy and energy dispersive X-ray spectroscopy. A dense, columnar and structurally inhomogeneous CGO10 film, i.e. exhibiting grain size refinement across the film thickness, is obtained in the deposition process. The cerium M4,5 edges, used to monitor the local electronic structure of the grains...

  2. Identification of cow milk in goat milk by nonlinear chemical fingerprint technique.

    Science.gov (United States)

    Ma, Yong-Jie; Dong, Wen-Bin; Fan, Cheng; Wang, Er-Dan

    2017-10-01

    The objective of this paper was to develop a nonlinear chemical fingerprint technique for identifying and detecting adulteration of goat milk with cow milk. In this study, by taking the Belousov-Zhabotinsky oscillatory chemical reaction using acetone and substrates in goat milk or cow milk as main dissipative substances, when the same dosage of goat milk and cow milk was introduced to the "H +  + Mn 2+  + BrO 3 -  + acetone" oscillating system respectively, nonlinear chemical fingerprints were obtained for goat milk and cow milk from the same origin. The results showed that inductive time value and the content of cow milk in goat milk had a linear relationship in the range of 0-100% and the corresponding regression coefficient was 0.9991. A detection limit of 0.0107 g/g was obtained, and the content of cow milk in mixed milk was calculated. The proposed method in this study was simple, economical and effective. In addition, the method did not need the pretreatment and separation of samples for identifying and evaluating cow milk adulteration in goat milk. Copyright © 2017. Published by Elsevier B.V.

  3. Determination of alpha-naphthol by an oscillating chemical reaction using the analyte pulse perturbation technique

    International Nuclear Information System (INIS)

    Yang Wu; Sun Kanjun; Lv Weilian; Bo Lili; He Xiaoyan; Suo Nan; Gao Jinzhang

    2005-01-01

    An analytical method for the determination of alpha-naphthol (α-NP) is proposed by the sequential perturbation caused by different amounts of alpha-naphthol on the oscillating chemical system involving the Cu(II)-catalyzed oscillating reaction between hydrogen peroxide and sodium thiocyanate in an alkaline medium with the aid of continuous-flow stirred tank reactor (CSTR). The method relies on the linear relationship between the changes in the oscillation amplitude of the chemical system and the concentration of alpha-naphthol. The use of the analyte pulse perturbation technique permits sequential determinations in the same oscillating system owing to the expeditiousness with which the steady state is regained after each perturbation. The calibration curve obeys a linear equation very well when the concentration of alpha-naphthol is over the range 0.034-530 umol/L (r = 0.9991). Influences of temperature, injection points, flow rate and reaction variables on the oscillating system are investigated in detail and the possible mechanism of action of alpha-naphthol to the chemical oscillating system is also discussed. The method has been successfully used for the determination of α-naphthol in carbaryl hydrolysates

  4. Droplet microfluidics in (bio) chemical analysis

    Czech Academy of Sciences Publication Activity Database

    Basova, E. Y.; Foret, František

    2015-01-01

    Roč. 140, č. 1 (2015), s. 22-38 ISSN 0003-2654 R&D Projects: GA ČR(CZ) GBP206/12/G014 Institutional support: RVO:68081715 Keywords : droplet chemistry * bio analysis * microfluidics * protein Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.033, year: 2015

  5. Chemical composition, antimicrobial activity, proximate analysis and ...

    African Journals Online (AJOL)

    Detarium senegalense JF Gmelin (Caesalpiniaceae), commonly known as tallow tree, is used traditionally for the treatment of bronchitis, pneumonia, internal complaints and skin diseases in Tropical Africa. The seed is used as a soup thickener in Eastern Nigeria. Analysis of the petroleum ether extract of the seeds with ...

  6. A study of essential elements in ancient Thai fighting swords by chemical and nuclear techniques

    International Nuclear Information System (INIS)

    Janposri, K.

    1980-01-01

    Four ancient Thai fighting swords from the Bangkok National Museum and iron ore from Kao Tab Kwai, Lopburi were studied by neutron activation analysis, metallography and chemical analysis. The results of these scientific studies show that all of these four swords are made of plain carbon steel, containing trace elements which have no effect on the physical and mechanical properties of the steel. The trace elements which were found in the iron ore are quite similar to those found in one of these swords. This means that the iron in one of the swords may have come from ore found at Kao Tab Kwai, Lopburi

  7. A technique for human error analysis (ATHEANA)

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, S.E.; Ramey-Smith, A.M.; Wreathall, J.; Parry, G.W. [and others

    1996-05-01

    Probabilistic risk assessment (PRA) has become an important tool in the nuclear power industry, both for the Nuclear Regulatory Commission (NRC) and the operating utilities. Human reliability analysis (HRA) is a critical element of PRA; however, limitations in the analysis of human actions in PRAs have long been recognized as a constraint when using PRA. A multidisciplinary HRA framework has been developed with the objective of providing a structured approach for analyzing operating experience and understanding nuclear plant safety, human error, and the underlying factors that affect them. The concepts of the framework have matured into a rudimentary working HRA method. A trial application of the method has demonstrated that it is possible to identify potentially significant human failure events from actual operating experience which are not generally included in current PRAs, as well as to identify associated performance shaping factors and plant conditions that have an observable impact on the frequency of core damage. A general process was developed, albeit in preliminary form, that addresses the iterative steps of defining human failure events and estimating their probabilities using search schemes. Additionally, a knowledge- base was developed which describes the links between performance shaping factors and resulting unsafe actions.

  8. A technique for human error analysis (ATHEANA)

    International Nuclear Information System (INIS)

    Cooper, S.E.; Ramey-Smith, A.M.; Wreathall, J.; Parry, G.W.

    1996-05-01

    Probabilistic risk assessment (PRA) has become an important tool in the nuclear power industry, both for the Nuclear Regulatory Commission (NRC) and the operating utilities. Human reliability analysis (HRA) is a critical element of PRA; however, limitations in the analysis of human actions in PRAs have long been recognized as a constraint when using PRA. A multidisciplinary HRA framework has been developed with the objective of providing a structured approach for analyzing operating experience and understanding nuclear plant safety, human error, and the underlying factors that affect them. The concepts of the framework have matured into a rudimentary working HRA method. A trial application of the method has demonstrated that it is possible to identify potentially significant human failure events from actual operating experience which are not generally included in current PRAs, as well as to identify associated performance shaping factors and plant conditions that have an observable impact on the frequency of core damage. A general process was developed, albeit in preliminary form, that addresses the iterative steps of defining human failure events and estimating their probabilities using search schemes. Additionally, a knowledge- base was developed which describes the links between performance shaping factors and resulting unsafe actions

  9. Urine storage under refrigeration preserves the sample in chemical, cellularity and bacteriuria analysis of ACS

    OpenAIRE

    Karen Cristina Barcellos Ribeiro; Bruno Rotondo Levenhagem Serabion; Eduardo Lima Nolasco; Chislene Pereira Vanelli; Harleson Lopes de Mesquita; José Otávio do Amaral Corrêa

    2013-01-01

    INTRODUCTION: The analysis of urine abnormal constituents and sediment (ACS) comprises tests of great diagnostic and prognostic value in clinical practice. When the analysis of ACS cannot be performed within two hours after collection, the sample must be preserved in order to avoid pre-analytical interferences. Refrigeration is the most applied technique due to its cost effectiveness. Moreover, it presents fewer inconveniences when compared to chemical preservation. However, changes in ACS ma...

  10. Chemical analysis of rare earth elements

    International Nuclear Information System (INIS)

    Tsukahara, Ryoichi; Sakoh, Takefumi; Nagai, Iwao

    1994-01-01

    Recently attention has been paid to ICP-AES or ICP-MS, and the reports on the analysis of rare earth elements by utilizing these methods continue to increase. These reports have become to take about 30% of the reports on rare earth analysis, and this is because these methods are highly sensitive to rare earth elements, and also these methods have spread widely. In ICP-AES and ICP-MS, mostly solution samples are measured, therefore, solids must be made into solution. At the time of quantitatively determining the rare earth elements of low concentration, separation and concentration are necessary. Referring to the literatures reported partially in 1990 and from 1991 to 1993, the progress of ICP-AES and ICP-MS is reported. Rare earth oxides and the alloys containing rare earth elements are easily decomposed with acids, but the decomposition of rocks is difficult, and its method is discussed. The separation of the rare earth elements from others in geochemical samples, cation exchange process is frequently utilized. Also solvent extraction process has been studied. For the separation of rare earth elements mutually, chromatography is used. The spectral interference in spectral analysis was studied. The comparison of these methods with other methods is reported. (K.I)

  11. Process Analysis in Chemical Plant by Means of Radioactive Tracers

    Energy Technology Data Exchange (ETDEWEB)

    Hirayama, T.; Hamada, K.; Osada, K. [Showa Denko K.K., Tokyo (Japan)

    1967-06-15

    Following the movement of solids and fluids is important in chemical processes to determine mixing efficiency and residence time. Since it is necessary to follow many complex substances such as raw materials, intermediates and reactants in plant investigations, it is often necessary to ascertain whether the behaviour of the radioisotope tracer and the substance to be traced are identical. The most difficult problem is to determine the best method of labelling, a factor which is a substantial key to the success of an experiment. Usually, there are three labelling techniques: radioisotope labelling, pre-.activation of the material and post-activation of the material. This paper deals with practical examples of the double-tracer technique, a combination of conventional radioisotope labelling and post-activation methods by means of activation analysis. In process analysis by means of tracers, a practical measurement method should also be devised and developed for each experiment. Phosphorus-32 and gold (non-radioactive) were used to measure retention time in a carbon-black plant. The radioisotope was pumped into a feed-stock pipe positioned before the reactor and samples were taken from each process of the plant, including the bag filter, mixer and product tank. After sampling from each step of the process, {sup 32}P in a semi-infinite powder sample was measured in situ by beta counting, and the gold was measured by gamma counting after activating the sample in a reactor. The experiment showed that both tracers had the same residence time, which was shorter than expected. Useful data were also obtained from the dispersion pattern of the material flow for future operation controls, including the time required to change from one grade of product to another. Practical tracer techniques to measure mixing characteristics in high-speed gas flows using {sup 85}Kr have been developed. A study of the measurement method was conducted by calculating the differential values of

  12. Development of a systematic methodology to select hazard analysis techniques for nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Vasconcelos, Vanderley de; Reis, Sergio Carneiro dos; Costa, Antonio Carlos Lopes da [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)]. E-mails: vasconv@cdtn.br; reissc@cdtn.br; aclc@cdtn.br; Jordao, Elizabete [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Faculdade de Engenharia Quimica]. E-mail: bete@feq.unicamp.br

    2008-07-01

    In order to comply with licensing requirements of regulatory bodies risk assessments of nuclear facilities should be carried out. In Brazil, such assessments are part of the Safety Analysis Reports, required by CNEN (Brazilian Nuclear Energy Commission), and of the Risk Analysis Studies, required by the competent environmental bodies. A risk assessment generally includes the identification of the hazards and accident sequences that can occur, as well as the estimation of the frequencies and effects of these unwanted events on the plant, people, and environment. The hazard identification and analysis are also particularly important when implementing an Integrated Safety, Health, and Environment Management System following ISO 14001, BS 8800 and OHSAS 18001 standards. Among the myriad of tools that help the process of hazard analysis can be highlighted: CCA (Cause- Consequence Analysis); CL (Checklist Analysis); ETA (Event Tree Analysis); FMEA (Failure Mode and Effects Analysis); FMECA (Failure Mode, Effects and Criticality Analysis); FTA (Fault Tree Analysis); HAZOP (Hazard and Operability Study); HRA (Human Reliability Analysis); Pareto Analysis; PHA (Preliminary Hazard Analysis); RR (Relative Ranking); SR (Safety Review); WI (What-If); and WI/CL (What-If/Checklist Analysis). The choice of a particular technique or a combination of techniques depends on many factors like motivation of the analysis, available data, complexity of the process being analyzed, expertise available on hazard analysis, and initial perception of the involved risks. This paper presents a systematic methodology to select the most suitable set of tools to conduct the hazard analysis, taking into account the mentioned involved factors. Considering that non-reactor nuclear facilities are, to a large extent, chemical processing plants, the developed approach can also be applied to analysis of chemical and petrochemical plants. The selected hazard analysis techniques can support cost

  13. Development of a systematic methodology to select hazard analysis techniques for nuclear facilities

    International Nuclear Information System (INIS)

    Vasconcelos, Vanderley de; Reis, Sergio Carneiro dos; Costa, Antonio Carlos Lopes da; Jordao, Elizabete

    2008-01-01

    In order to comply with licensing requirements of regulatory bodies risk assessments of nuclear facilities should be carried out. In Brazil, such assessments are part of the Safety Analysis Reports, required by CNEN (Brazilian Nuclear Energy Commission), and of the Risk Analysis Studies, required by the competent environmental bodies. A risk assessment generally includes the identification of the hazards and accident sequences that can occur, as well as the estimation of the frequencies and effects of these unwanted events on the plant, people, and environment. The hazard identification and analysis are also particularly important when implementing an Integrated Safety, Health, and Environment Management System following ISO 14001, BS 8800 and OHSAS 18001 standards. Among the myriad of tools that help the process of hazard analysis can be highlighted: CCA (Cause- Consequence Analysis); CL (Checklist Analysis); ETA (Event Tree Analysis); FMEA (Failure Mode and Effects Analysis); FMECA (Failure Mode, Effects and Criticality Analysis); FTA (Fault Tree Analysis); HAZOP (Hazard and Operability Study); HRA (Human Reliability Analysis); Pareto Analysis; PHA (Preliminary Hazard Analysis); RR (Relative Ranking); SR (Safety Review); WI (What-If); and WI/CL (What-If/Checklist Analysis). The choice of a particular technique or a combination of techniques depends on many factors like motivation of the analysis, available data, complexity of the process being analyzed, expertise available on hazard analysis, and initial perception of the involved risks. This paper presents a systematic methodology to select the most suitable set of tools to conduct the hazard analysis, taking into account the mentioned involved factors. Considering that non-reactor nuclear facilities are, to a large extent, chemical processing plants, the developed approach can also be applied to analysis of chemical and petrochemical plants. The selected hazard analysis techniques can support cost

  14. Avogadro: an advanced semantic chemical editor, visualization, and analysis platform

    Directory of Open Access Journals (Sweden)

    Hanwell Marcus D

    2012-08-01

    Full Text Available Abstract Background The Avogadro project has developed an advanced molecule editor and visualizer designed for cross-platform use in computational chemistry, molecular modeling, bioinformatics, materials science, and related areas. It offers flexible, high quality rendering, and a powerful plugin architecture. Typical uses include building molecular structures, formatting input files, and analyzing output of a wide variety of computational chemistry packages. By using the CML file format as its native document type, Avogadro seeks to enhance the semantic accessibility of chemical data types. Results The work presented here details the Avogadro library, which is a framework providing a code library and application programming interface (API with three-dimensional visualization capabilities; and has direct applications to research and education in the fields of chemistry, physics, materials science, and biology. The Avogadro application provides a rich graphical interface using dynamically loaded plugins through the library itself. The application and library can each be extended by implementing a plugin module in C++ or Python to explore different visualization techniques, build/manipulate molecular structures, and interact with other programs. We describe some example extensions, one which uses a genetic algorithm to find stable crystal structures, and one which interfaces with the PackMol program to create packed, solvated structures for molecular dynamics simulations. The 1.0 release series of Avogadro is the main focus of the results discussed here. Conclusions Avogadro offers a semantic chemical builder and platform for visualization and analysis. For users, it offers an easy-to-use builder, integrated support for downloading from common databases such as PubChem and the Protein Data Bank, extracting chemical data from a wide variety of formats, including computational chemistry output, and native, semantic support for the CML file format

  15. Advanced chemical analysis service for elements, radionuclides and phases

    International Nuclear Information System (INIS)

    Sansoni, B.

    1986-01-01

    A review is given on the structure, organisation and performance of the chemical analysis service of the Central Department for Chemical Analysis at the Kernforschungsanlage Juelich GmbH. The research and development programs together with the infrastructure of the Centre afford to analyse almost all stable elements of the periodical table in almost any material. The corresponding chemical analysis service has been organized according to a new modular system of analytical steps. According to this, the most complicated and, therefore, most general case of an analytical scheme for element and radionuclide analysis in any type of material can be differentiated into about 14 different steps, the modules. They are more or less independent of the special problem. The laboratory is designed and organized according to these steps. (orig./PW) [de

  16. Chemical kinetic functional sensitivity analysis: Elementary sensitivities

    International Nuclear Information System (INIS)

    Demiralp, M.; Rabitz, H.

    1981-01-01

    Sensitivity analysis is considered for kinetics problems defined in the space--time domain. This extends an earlier temporal Green's function method to handle calculations of elementary functional sensitivities deltau/sub i//deltaα/sub j/ where u/sub i/ is the ith species concentration and α/sub j/ is the jth system parameter. The system parameters include rate constants, diffusion coefficients, initial conditions, boundary conditions, or any other well-defined variables in the kinetic equations. These parameters are generally considered to be functions of position and/or time. Derivation of the governing equations for the sensitivities and the Green's funciton are presented. The physical interpretation of the Green's function and sensitivities is given along with a discussion of the relation of this work to earlier research

  17. Contributions to fuzzy polynomial techniques for stability analysis and control

    OpenAIRE

    Pitarch Pérez, José Luis

    2014-01-01

    The present thesis employs fuzzy-polynomial control techniques in order to improve the stability analysis and control of nonlinear systems. Initially, it reviews the more extended techniques in the field of Takagi-Sugeno fuzzy systems, such as the more relevant results about polynomial and fuzzy polynomial systems. The basic framework uses fuzzy polynomial models by Taylor series and sum-of-squares techniques (semidefinite programming) in order to obtain stability guarantees...

  18. Handbook of Basic Tables for Chemical Analysis. Final report

    International Nuclear Information System (INIS)

    Bruno, T.J.; Svoronos, P.D.N.

    1988-04-01

    This work began as a slim booklet prepared by one of the authors (TJB) to accompany a course on chemical instrumentation presented at the National Bureau of Standards, Boulder Laboratories. The booklet contained tables on chromatography, spectroscopy, and chemical (wet) methods, and was intended to provide the students with enough basic data to design their own analytical methods and procedures. Shortly thereafter, with the co-authorship of Prof. Paris D. N. Svoronos, it was expanded into a more-extensive compilation entitled Basic Tables for Chemical Analysis, published as National Bureau of Standards Technical Note 1096. That work has now been expanded and updated into the present body of tables. Although there have been considerable changes since the first version of these tables, the aim has remained essentially the same. The authors have tried to provide a single source of information for those practicing scientists and research students who must use various aspects of chemical analysis in their work. In this respect, it is geared less toward the researcher in analytical chemistry than to those practitioners in other chemical disciplines who must have routine use of chemical analysis

  19. An operator expansion technique for path integral analysis

    International Nuclear Information System (INIS)

    Tsvetkov, I.V.

    1995-01-01

    A new method of path integral analysis in the framework of a power series technique is presented. The method is based on the operator expansion of an exponential. A regular procedure to calculate the correction terms is found. (orig.)

  20. Search for the top quark using multivariate analysis techniques

    International Nuclear Information System (INIS)

    Bhat, P.C.

    1994-08-01

    The D0 collaboration is developing top search strategies using multivariate analysis techniques. We report here on applications of the H-matrix method to the eμ channel and neural networks to the e+jets channel

  1. Studying Chemical Reactions, One Bond at a Time, with Single Molecule AFM Techniques

    Science.gov (United States)

    Fernandez, Julio M.

    2008-03-01

    atomic force microscopy (AFM) techniques, as shown here, can probe dynamic rearrangements within an enzyme's active site which cannot be resolved with any other current structural biological technique. Furthermore, our work at the single bond level directly demonstrates that thiol/disulfide exchange in proteins is a force-dependent chemical reaction. Our findings suggest that mechanical force plays a role in disulfide reduction in vivo, a property which has never been explored by traditional biochemistry. 1.-Wiita, A.P., Ainavarapu, S.R.K., Huang, H.H. and Julio M. Fernandez (2006) Force-dependent chemical kinetics of disulfide bond reduction observed with single molecule techniques. Proc Natl Acad Sci U S A. 103(19):7222-7 2.-Wiita, A.P., Perez-Jimenez, R., Walther, K.A., Gräter, F. Berne, B.J., Holmgren, A., Sanchez-Ruiz, J.M., and Fernandez, J.M. (2007) Probing the chemistry of thioredoxin catalysis with force. Nature, 450:124-7.

  2. Separation and sampling technique of light element isotopes by chemical exchange process

    International Nuclear Information System (INIS)

    Kato, Shunsaku; Oi, Kenta; Takagi, Norio; Hirotsu, Takafumi; Kano, Hirofumi; Sonoda, Akinari; Makita, Yoji

    2000-01-01

    Lithium and boron isotope separation technique were studied. Granulation of lithium isotope separation agent was carried out by cure covering in solution. Separation of lithium isotope was stepped up by ammonium carbonate used as elusion agent. Styrene and ester resin derived three kinds of agents such as 2-amino-1, 3-propanediol (1, 3-PD), 2-amino-2-methyl-1, 3-propanediol (Me-1,3-PD) and tris(2-hydroxyethyl)amine (Tris) were used as absorbent.The ester resin with Tris showed larger amount of adsorption (1.4 mmol/g) than other resins. However, all resins with agent indicated more large adsorption volume of boron than the objective value (0.5 mmol/g). Large isotope shift was shown by the unsymmetrical vibration mode of lithium ion on the basis of quantum chemical calculation of isotope effect on dehydration of hydrated lithium ion. (S.Y.)

  3. Advancement in solar evaporation techniques for volume reduction of chemical effluents

    Energy Technology Data Exchange (ETDEWEB)

    Parakasamurthy, K S [Nuclear Fuel Complex, Hyderabad (India); Pande, D P [Process Engineering and Systems Development Division, Bhabha Atomic Research Centre, Mumbai (India)

    1994-06-01

    A typical example of advancement of a unit operation for the given requirement is described. The solar evaporation ponds (SEP) have technical and economic advantages compared to other evaporation methods for concentrating chemical effluents. The operation of SEP is strongly dependent on the environmental and site conditions. Tropical conditions with high solar incidence, good wind speed along with hot and dry weather provide suitable climate for efficient operation of solar evaporation ponds. The particular site selected for the ponds at Nuclear Fuel Complex (NFC) has a rocky terrain with murrum over sheet with very low water table and small velocity of groundwater. During the past twenty five years extensive theoretical and experimental investigations have been carried out for advancement of solar evaporation technique. (author). 7 refs.

  4. Advancement in solar evaporation techniques for volume reduction of chemical effluents

    International Nuclear Information System (INIS)

    Parakasamurthy, K.S.; Pande, D.P.

    1994-01-01

    A typical example of advancement of a unit operation for the given requirement is described. The solar evaporation ponds (SEP) have technical and economic advantages compared to other evaporation methods for concentrating chemical effluents. The operation of SEP is strongly dependent on the environmental and site conditions. Tropical conditions with high solar incidence, good wind speed along with hot and dry weather provide suitable climate for efficient operation of solar evaporation ponds. The particular site selected for the ponds at Nuclear Fuel Complex (NFC) has a rocky terrain with murrum over sheet with very low water table and small velocity of groundwater. During the past twenty five years extensive theoretical and experimental investigations have been carried out for advancement of solar evaporation technique. (author)

  5. Diameter Tuning of β-Ga2O3 Nanowires Using Chemical Vapor Deposition Technique.

    Science.gov (United States)

    Kumar, Mukesh; Kumar, Vikram; Singh, R

    2017-12-01

    Diameter tuning of [Formula: see text]-Ga 2 O 3 nanowires using chemical vapor deposition technique have been investigated under various experimental conditions. Diameter of root grown [Formula: see text]-Ga 2 O 3 nanowires having monoclinic crystal structure is tuned by varying separation distance between metal source and substrate. Effect of gas flow rate and mixer ratio on the morphology and diameter of nanowires has been studied. Nanowire diameter depends on growth temperature, and it is independent of catalyst nanoparticle size at higher growth temperature (850-900 °C) as compared to lower growth temperature (800 °C). These nanowires show changes in structural strain value with change in diameter. Band-gap of nanowires increases with decrease in the diameter.

  6. Proficiency Testing for Determination of Water Content in Toluene of Chemical Reagents by iteration robust statistic technique

    Science.gov (United States)

    Wang, Hao; Wang, Qunwei; He, Ming

    2018-05-01

    In order to investigate and improve the level of detection technology of water content in liquid chemical reagents of domestic laboratories, proficiency testing provider PT0031 (CNAS) has organized proficiency testing program of water content in toluene, 48 laboratories from 18 provinces/cities/municipals took part in the PT. This paper introduces the implementation process of proficiency testing for determination of water content in toluene, including sample preparation, homogeneity and stability test, the results of statistics of iteration robust statistic technique and analysis, summarized and analyzed those of the different test standards which are widely used in the laboratories, put forward the technological suggestions for the improvement of the test quality of water content. Satisfactory results were obtained by 43 laboratories, amounting to 89.6% of the total participating laboratories.

  7. Chemical composition and the nutritive value of pistachio epicarp (in situ degradation and in vitro gas production techniques

    Directory of Open Access Journals (Sweden)

    Somayeh Bakhshizadeh

    2014-04-01

    Full Text Available The nutritive value of pistachio epicarp (PE was evaluated by in situ and in vitro techniques. Chemical analysis indicated that PE was high in crude protein (11.30% and low in neutral detergent fiber (26.20%. Total phenols, total tannins, condensed tannins and hydrolysable tannins contents in PE were 8.29%, 4.48%, 0.49% and 3.79%, respectively. Ruminal dry matter and crude protein degradation after 48 hr incubation were 75.21% and 82.52%, respectively. The gas production volume at 48 hr for PE was 122.47 mL g-1DM. As a whole, adding polyethylene glycol (PEG to PE increased (p < 0.05 gas production volumes, organic matter digestibility and the metabolizable energy that illustrated inhibitory effect of phenolics on rumen microbial fermentation and the positive influence of PEG on digestion PE. The results showed that PE possessed potentials to being used as feed supplements.

  8. Characterizations on the microstructures of LiMn2O4 prepared by a simple soft-chemical technique

    International Nuclear Information System (INIS)

    Wei Yingjin; Kim, Kwang Bum; Chen Gang; Park, Chul W.

    2008-01-01

    LiMn 2 O 4 powders were prepared by a simple soft-chemical technique at different temperatures. X-ray diffraction and thermogravimetric analysis suggested that the material prepared at 800 deg. C was stoichiometric LiMn 2 O 4 , whereas those prepared at 600 and 700 deg. C were Li[Mn 0.77 3+ Mn 1.23 4+ ]O 4.115 and Li[Mn 0.85 3+ Mn 1.15 4+ ]O 4.075 . Several typical XRD peaks of the compounds were investigated with an aim to elucidate (i) the Li immigration to the 16d octahedral sites, (ii) the partial tetragonal phase transition of the material and (iii) the mean coherent domain size and microstrain. SEM study showed that the particle size of the materials increased with heating temperature. The activation energy for the material particle growth was determined as 30.4 kJ mol -1

  9. Chemical composition and the nutritive value of pistachio epicarp (in situ degradation and in vitro gas production techniques).

    Science.gov (United States)

    Bakhshizadeh, Somayeh; Taghizadeh, Akbar; Janmohammadi, Hossein; Alijani, Sadegh

    2014-01-01

    The nutritive value of pistachio epicarp (PE) was evaluated by in situ and in vitro techniques. Chemical analysis indicated that PE was high in crude protein (11.30%) and low in neutral detergent fiber (26.20%). Total phenols, total tannins, condensed tannins and hydrolysable tannins contents in PE were 8.29%, 4.48%, 0.49% and 3.79%, respectively. Ruminal dry matter and crude protein degradation after 48 hr incubation were 75.21% and 82.52%, respectively. The gas production volume at 48 hr for PE was 122.47 mL g(-1)DM. As a whole, adding polyethylene glycol (PEG) to PE increased (p gas production volumes, organic matter digestibility and the metabolizable energy that illustrated inhibitory effect of phenolics on rumen microbial fermentation and the positive influence of PEG on digestion PE. The results showed that PE possessed potentials to being used as feed supplements.

  10. Neutron activation analysis: an emerging technique for conservation/preservation

    International Nuclear Information System (INIS)

    Sayre, E.V.

    1976-01-01

    The diverse applications of neutron activation in analysis, preservation, and documentation of art works and artifacts are described with illustrations for each application. The uses of this technique to solve problems of attribution and authentication, to reveal the inner structure and composition of art objects, and, in some instances to recreate details of the objects are described. A brief discussion of the theory and techniques of neutron activation analysis is also included

  11. Development of evaluation method for software safety analysis techniques

    International Nuclear Information System (INIS)

    Huang, H.; Tu, W.; Shih, C.; Chen, C.; Yang, W.; Yih, S.; Kuo, C.; Chen, M.

    2006-01-01

    Full text: Full text: Following the massive adoption of digital Instrumentation and Control (I and C) system for nuclear power plant (NPP), various Software Safety Analysis (SSA) techniques are used to evaluate the NPP safety for adopting appropriate digital I and C system, and then to reduce risk to acceptable level. However, each technique has its specific advantage and disadvantage. If the two or more techniques can be complementarily incorporated, the SSA combination would be more acceptable. As a result, if proper evaluation criteria are available, the analyst can then choose appropriate technique combination to perform analysis on the basis of resources. This research evaluated the applicable software safety analysis techniques nowadays, such as, Preliminary Hazard Analysis (PHA), Failure Modes and Effects Analysis (FMEA), Fault Tree Analysis (FTA), Markov chain modeling, Dynamic Flowgraph Methodology (DFM), and simulation-based model analysis; and then determined indexes in view of their characteristics, which include dynamic capability, completeness, achievability, detail, signal/ noise ratio, complexity, and implementation cost. These indexes may help the decision makers and the software safety analysts to choose the best SSA combination arrange their own software safety plan. By this proposed method, the analysts can evaluate various SSA combinations for specific purpose. According to the case study results, the traditional PHA + FMEA + FTA (with failure rate) + Markov chain modeling (without transfer rate) combination is not competitive due to the dilemma for obtaining acceptable software failure rates. However, the systematic architecture of FTA and Markov chain modeling is still valuable for realizing the software fault structure. The system centric techniques, such as DFM and Simulation-based model analysis, show the advantage on dynamic capability, achievability, detail, signal/noise ratio. However, their disadvantage are the completeness complexity

  12. Evaluation of electrode surface modification techniques for the development of chemical sensors

    International Nuclear Information System (INIS)

    Galiatsatos, C.

    1988-01-01

    This thesis covers several aspects of electrode surface modification techniques. The successful application of gamma-radiation to create polymer-coated electrodes, where the polymers can be ion exchangers and consequently of great analytical interest by themselves (such as the polymer poly(diallyl) dimethyl ammonium chloride) or where some other neutral polymers can function as convenient matrices for the introduction of biomolecules and/or other electrochemically interesting species is reported. This is demonstrated by using the neutral polymer poly(vinyl alcohol) (PVAL) as a matrix for immobilization of the enzyme glucose oxidase and the mediator methyl viologen. The effect of γ-radiation on PVAL is discussed, as well as swelling properties of the irradiated polymers and specific characteristics of the created chemical sensors. Results of an experiment where the various kinds of interactions between the ion-exchange polymer Nafion and some positively charged species are explored are reported, and a model system for competition (methyl viologen vs. ruthenium hexaamine) which increases significantly our understanding of the interaction is mentioned. The effect of γ-radiation on Nafion and its ion-exchange compabilities is discussed also. A system of conduction polymers primarily polypyrrole, used as a detector of electroinactive anions due to their doping-undergoing in the film is discussed. Preliminary results on a new method that involves chemical cross-linking of a triisocyane molecule with -OH containing polymers in the presence of enzymes are reported

  13. Applications of factor analysis to electron and ion beam surface techniques

    International Nuclear Information System (INIS)

    Solomon, J.S.

    1987-01-01

    Factor analysis, a mathematical technique for extracting chemical information from matrices of data, is used to enhance Auger electron spectroscopy (AES), core level electron energy loss spectroscopy (EELS), ion scattering spectroscopy (ISS), and secondary ion mass spectroscopy (SIMS) in studies of interfaces, thin films, and surfaces. Several examples of factor analysis enhancement of chemical bonding variations in thin films and at interfaces studied with AES and SIMS are presented. Factor analysis is also shown to be of great benefit in quantifying electron and ion beam doses required to induce surface damage. Finally, examples are presented of the use of factor analysis to reconstruct elemental profiles when peaks of interest overlap each other during the course of depth profile analysis. (author)

  14. Use of Modern Chemical Protein Synthesis and Advanced Fluorescent Assay Techniques to Experimentally Validate the Functional Annotation of Microbial Genomes

    Energy Technology Data Exchange (ETDEWEB)

    Kent, Stephen [University of Chicago

    2012-07-20

    The objective of this research program was to prototype methods for the chemical synthesis of predicted protein molecules in annotated microbial genomes. High throughput chemical methods were to be used to make large numbers of predicted proteins and protein domains, based on microbial genome sequences. Microscale chemical synthesis methods for the parallel preparation of peptide-thioester building blocks were developed; these peptide segments are used for the parallel chemical synthesis of proteins and protein domains. Ultimately, it is envisaged that these synthetic molecules would be ‘printed’ in spatially addressable arrays. The unique ability of total synthesis to precision label protein molecules with dyes and with chemical or biochemical ‘tags’ can be used to facilitate novel assay technologies adapted from state-of-the art single molecule fluorescence detection techniques. In the future, in conjunction with modern laboratory automation this integrated set of techniques will enable high throughput experimental validation of the functional annotation of microbial genomes.

  15. Research on digital multi-channel pulse height analysis techniques

    International Nuclear Information System (INIS)

    Xiao Wuyun; Wei Yixiang; Ai Xianyun; Ao Qi

    2005-01-01

    Multi-channel pulse height analysis techniques are developing in the direction of digitalization. Based on digital signal processing techniques, digital multi-channel analyzers are characterized by powerful pulse processing ability, high throughput, improved stability and flexibility. This paper analyzes key techniques of digital nuclear pulse processing. With MATLAB software, main algorithms are simulated, such as trapezoidal shaping, digital baseline estimation, digital pole-zero/zero-pole compensation, poles and zeros identification. The preliminary general scheme of digital MCA is discussed, as well as some other important techniques about its engineering design. All these lay the foundation of developing homemade digital nuclear spectrometers. (authors)

  16. Implementing systematic review techniques in chemical risk assessment: Challenges, opportunities and recommendations.

    Science.gov (United States)

    Whaley, Paul; Halsall, Crispin; Ågerstrand, Marlene; Aiassa, Elisa; Benford, Diane; Bilotta, Gary; Coggon, David; Collins, Chris; Dempsey, Ciara; Duarte-Davidson, Raquel; FitzGerald, Rex; Galay-Burgos, Malyka; Gee, David; Hoffmann, Sebastian; Lam, Juleen; Lasserson, Toby; Levy, Len; Lipworth, Steven; Ross, Sarah Mackenzie; Martin, Olwenn; Meads, Catherine; Meyer-Baron, Monika; Miller, James; Pease, Camilla; Rooney, Andrew; Sapiets, Alison; Stewart, Gavin; Taylor, David

    2016-01-01

    Systematic review (SR) is a rigorous, protocol-driven approach designed to minimise error and bias when summarising the body of research evidence relevant to a specific scientific question. Taking as a comparator the use of SR in synthesising research in healthcare, we argue that SR methods could also pave the way for a "step change" in the transparency, objectivity and communication of chemical risk assessments (CRA) in Europe and elsewhere. We suggest that current controversies around the safety of certain chemicals are partly due to limitations in current CRA procedures which have contributed to ambiguity about the health risks posed by these substances. We present an overview of how SR methods can be applied to the assessment of risks from chemicals, and indicate how challenges in adapting SR methods from healthcare research to the CRA context might be overcome. Regarding the latter, we report the outcomes from a workshop exploring how to increase uptake of SR methods, attended by experts representing a wide range of fields related to chemical toxicology, risk analysis and SR. Priorities which were identified include: the conduct of CRA-focused prototype SRs; the development of a recognised standard of reporting and conduct for SRs in toxicology and CRA; and establishing a network to facilitate research, communication and training in SR methods. We see this paper as a milestone in the creation of a research climate that fosters communication between experts in CRA and SR and facilitates wider uptake of SR methods into CRA. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Sensitivity analysis and related analysis : A survey of statistical techniques

    NARCIS (Netherlands)

    Kleijnen, J.P.C.

    1995-01-01

    This paper reviews the state of the art in five related types of analysis, namely (i) sensitivity or what-if analysis, (ii) uncertainty or risk analysis, (iii) screening, (iv) validation, and (v) optimization. The main question is: when should which type of analysis be applied; which statistical

  18. Key-space analysis of double random phase encryption technique

    Science.gov (United States)

    Monaghan, David S.; Gopinathan, Unnikrishnan; Naughton, Thomas J.; Sheridan, John T.

    2007-09-01

    We perform a numerical analysis on the double random phase encryption/decryption technique. The key-space of an encryption technique is the set of possible keys that can be used to encode data using that technique. In the case of a strong encryption scheme, many keys must be tried in any brute-force attack on that technique. Traditionally, designers of optical image encryption systems demonstrate only how a small number of arbitrary keys cannot decrypt a chosen encrypted image in their system. However, this type of demonstration does not discuss the properties of the key-space nor refute the feasibility of an efficient brute-force attack. To clarify these issues we present a key-space analysis of the technique. For a range of problem instances we plot the distribution of decryption errors in the key-space indicating the lack of feasibility of a simple brute-force attack.

  19. ANALYSIS OF SAMPLES FROM TANK 5F CHEMICAL CLEANING

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, M.; Fink, S.

    2011-03-07

    The Savannah River Site (SRS) is preparing Tank 5F for closure. The first step in preparing the tank for closure is mechanical sludge removal. Following mechanical sludge removal, SRS performed chemical cleaning with oxalic acid to remove the sludge heel. Personnel are currently assessing the effectiveness of the chemical cleaning. SRS personnel collected liquid samples during chemical cleaning and submitted them to Savannah River National Laboratory (SRNL) for analysis. Following chemical cleaning, they collected a solid sample (also known as 'process sample') and submitted it to SRNL for analysis. The authors analyzed these samples to assess the effectiveness of the chemical cleaning process. The conclusions from this work are: (1) With the exception of iron, the dissolution of sludge components from Tank 5F agreed with results from the actual waste demonstration performed in 2007. The fraction of iron removed from Tank 5F by chemical cleaning was significantly less than the fraction removed in the SRNL demonstrations. The likely cause of this difference is the high pH following the first oxalic acid strike. (2) Most of the sludge mass remaining in the tank is iron and nickel. (3) The remaining sludge contains approximately 26 kg of barium, 37 kg of chromium, and 37 kg of mercury. (4) Most of the radioactivity remaining in the residual material is beta emitters and {sup 90}Sr. (5) The chemical cleaning removed more than {approx} 90% of the uranium isotopes and {sup 137}Cs. (6) The chemical cleaning removed {approx} 70% of the neptunium, {approx} 83% of the {sup 90}Sr, and {approx} 21% of the {sup 60}Co. (7) The chemical cleaning removed less than 10% of the plutonium, americium, and curium isotopes. (8) The chemical cleaning removed more than 90% of the aluminium, calcium, and sodium from the tank. (9) The cleaning operations removed 61% of lithium, 88% of non-radioactive strontium, and 65% of zirconium. The {sup 90}Sr and non-radioactive strontium were

  20. Construction of an experimental simplified model for determining of flow parameters in chemical reactors, using nuclear techniques

    International Nuclear Information System (INIS)

    Araujo Paiva, J.A. de.

    1981-03-01

    The development of a simplified experimental model for investigation of nuclear techniques to determine the solid phase parameters in gas-solid flows is presented. A method for the measurement of the solid phase residence time inside a chemical reactor of the type utilised in the cracking process of catalytic fluids is described. An appropriate radioactive labelling technique of the solid phase and the construction of an eletronic timing circuit were the principal stages in the definition of measurement technique. (Author) [pt

  1. Prompt gamma-ray spectroscopy and its use for the elemental chemical analysis

    International Nuclear Information System (INIS)

    Deconninck, G.; Demortier, G.; Bodart, F.

    The elemental chemical analysis by nuclear techniques has been widely developed since a quarter of century. In this review the analysis by irradiation of the the sample (solid or liquid) of a majority of chemical elements by means of the charged particles and the detection during this irradiation of the gamma photons characteristic of the element are considered. After a brief account of the physical phenomena peculiar to the prompt detection of photons in comparison with the activation methods where a delayed activity is measured, a brief description of the experimental equipment for this kind of analysis is given. A comprehensive critical survey of the recent applications to the analysis of metals, semiconductors and electric insulating substances is presented. The necessary informations for the choice of the nuclear reaction to use for a specific analysis are contained in a set of tables. (AF)

  2. Nuclear techniques for bulk and surface analysis of materials

    International Nuclear Information System (INIS)

    D'Agostino, M.D.; Kamykowski, E.A.; Kuehne, F.J.; Padawer, G.M.; Schneid, E.J.; Schulte, R.L.; Stauber, M.C.; Swanson, F.R.

    1978-01-01

    A review is presented summarizing several nondestructive bulk and surface analysis nuclear techniques developed in the Grumman Research Laboratories. Bulk analysis techniques include 14-MeV-neutron activation analysis and accelerator-based neutron radiography. The surface analysis techniques include resonant and non-resonant nuclear microprobes for the depth profile analysis of light elements (H, He, Li, Be, C, N, O and F) in the surface of materials. Emphasis is placed on the description and discussion of the unique nuclear microprobe analytical capacibilities of immediate importance to a number of current problems facing materials specialists. The resolution and contrast of neutron radiography was illustrated with an operating heat pipe system. The figure shows that the neutron radiograph has a resolution of better than 0.04 cm with sufficient contrast to indicate Freon 21 on the inner capillaries of the heat pipe and pooling of the liquid at the bottom. (T.G.)

  3. Computational singular perturbation analysis of stochastic chemical systems with stiffness

    Science.gov (United States)

    Wang, Lijin; Han, Xiaoying; Cao, Yanzhao; Najm, Habib N.

    2017-04-01

    Computational singular perturbation (CSP) is a useful method for analysis, reduction, and time integration of stiff ordinary differential equation systems. It has found dominant utility, in particular, in chemical reaction systems with a large range of time scales at continuum and deterministic level. On the other hand, CSP is not directly applicable to chemical reaction systems at micro or meso-scale, where stochasticity plays an non-negligible role and thus has to be taken into account. In this work we develop a novel stochastic computational singular perturbation (SCSP) analysis and time integration framework, and associated algorithm, that can be used to not only construct accurately and efficiently the numerical solutions to stiff stochastic chemical reaction systems, but also analyze the dynamics of the reduced stochastic reaction systems. The algorithm is illustrated by an application to a benchmark stochastic differential equation model, and numerical experiments are carried out to demonstrate the effectiveness of the construction.

  4. Meta-analysis in a nutshell: Techniques and general findings

    DEFF Research Database (Denmark)

    Paldam, Martin

    2015-01-01

    The purpose of this article is to introduce the technique and main findings of meta-analysis to the reader, who is unfamiliar with the field and has the usual objections. A meta-analysis is a quantitative survey of a literature reporting estimates of the same parameter. The funnel showing...

  5. 48 CFR 15.404-1 - Proposal analysis techniques.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Proposal analysis techniques. 15.404-1 Section 15.404-1 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... assistance of other experts to ensure that an appropriate analysis is performed. (6) Recommendations or...

  6. NMR and modelling techniques in structural and conformation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, R J [Liverpool Univ. (United Kingdom)

    1994-12-31

    The use of Lanthanide Induced Shifts (L.I.S.) and modelling techniques in conformational analysis is presented. The use of Co{sup III} porphyrins as shift reagents is discussed, with examples of their use in the conformational analysis of some heterocyclic amines. (author) 13 refs., 9 figs.

  7. Application of nuclear analysis techniques in ancient chinese porcelain

    International Nuclear Information System (INIS)

    Feng Songlin; Xu Qing; Feng Xiangqian; Lei Yong; Cheng Lin; Wang Yanqing

    2005-01-01

    Ancient ceramic was fired with porcelain clay. It contains various provenance information and age characteristic. It is the scientific foundation of studying Chinese porcelain to analyze and research the ancient ceramic with modern analysis methods. According to the property of nuclear analysis technique, its function and application are discussed. (authors)

  8. SWOT ANALYSIS-MANAGEMENT TECHNIQUES TO STREAMLINE PUBLIC BUSINESS MANAGEMENT

    OpenAIRE

    Rodica IVORSCHI

    2012-01-01

    SWOT analysis is the most important management techniques for understanding the strategic position of an organization. Objective SWOT analysis is to recommend strategies to ensure the best alignment between internal and external environment, and choosing the right strategy can be benefi cial organization in order to adapt their strengths to opportunities, minimize risks and eliminate weaknesses.

  9. SWOT ANALYSIS-MANAGEMENT TECHNIQUES TO STREAMLINE PUBLIC BUSINESS MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Rodica IVORSCHI

    2012-06-01

    Full Text Available SWOT analysis is the most important management techniques for understanding the strategic position of an organization.Objective SWOT analysis is to recommend strategies to ensure the best alignment between internal and external environment, and choosing the right strategy can be beneficial organization in order to adapt their strengths to opportunities, minimize risks and eliminate weaknesses.

  10. Speciation of trace elements in biological samples by nuclear analytical and related techniques coupled with chemical and biochemical separation

    International Nuclear Information System (INIS)

    Chen, C.Y.; Gao, Y.X.; Li, B.; Yu, H.W.; Li, Y.F.; Sun, J.; Chai, Z.F.

    2005-01-01

    In the past, most analytical problems relating to biological systems were addressed by measuring the total concentrations of elements. Now there is increasing interest of the importance of their chemical forms, in which an element is present in biological systems, e.g., the oxidation state, the binding state with macromolecules, or even the molecular structure. The biological effects of chromium, which is classified as an essential nutrient, are dependent upon its oxidation. state. In general, trivalent chromium is biochemically active, whereas hexavalent chromium is considered to be toxic. Mercury is one of serious environmental persistent pollutants. However, organic forms of mercury are known to possess much higher toxicity than inorganic mercury. Therefore, information on speciation is critically required in order to better understanding of their bioavailability, metabolism, transformation, and toxicity in vivo. Recently, chemical speciation of selenium, mercury, copper, zinc, iron, and so on, has been investigated by INAA, ICP-MS, XRF, EXAFS and related techniques combined with chemical and biochemical separation (extraction, chromatography, gel electrophoresis, etc.). INAA, XRF, and ICP-MS have superior advantages in aspect of multielemental analysis with high accuracy and sensitivity, which render the possibility of analyzing various elements of interest simultaneously. These offline or online techniques have been flexibly applied to different biological matrixes, such as human hair, serum, urine, various tissues and organs in our researches. In addition, EXAFS provides structural information about the moiety of metal centers up to a distance of approximately 4-5 Anstrom. For instance, hepatocellular carcinoma (HCC) is one of the most common cancers worldwide. Imbalance of elements, such as Se, Zn, Fe, Cu, Cd, Ca, etc., has been found in the whole blood or serum of patients with HCC. We found that the profiles of Se, Cd, Fe, Zn and Cu-containing proteins

  11. Microscopy and Chemical Inversing Techniques to Determine the Photonic Crystal Structure of Iridescent Beetle Scales in the Cerambycidae Family

    Science.gov (United States)

    Richey, Lauren; Gardner, John; Standing, Michael; Jorgensen, Matthew; Bartl, Michael

    2010-10-01

    Photonic crystals (PCs) are periodic structures that manipulate electromagnetic waves by defining allowed and forbidden frequency bands known as photonic band gaps. Despite production of PC structures operating at infrared wavelengths, visible counterparts are difficult to fabricate because periodicities must satisfy the diffraction criteria. As part of an ongoing search for naturally occurring PCs [1], a three-dimensional array of nanoscopic spheres in the iridescent scales of the Cerambycidae insects A. elegans and G. celestis has been found. Such arrays are similar to opal gemstones and self-assembled colloidal spheres which can be chemically inverted to create a lattice-like PC. Through a chemical replication process [2], scanning electron microscopy analysis, sequential focused ion beam slicing and three-dimensional modeling, we analyzed the structural arrangement of the nanoscopic spheres. The study of naturally occurring structures and their inversing techniques into PCs allows for diversity in optical PC fabrication. [1] J.W. Galusha et al., Phys. Rev. E 77 (2008) 050904. [2] J.W. Galusha et al., J. Mater. Chem. 20 (2010) 1277.

  12. Kinematics analysis technique fouettes 720° classic ballet.

    Directory of Open Access Journals (Sweden)

    Li Bo

    2011-07-01

    Full Text Available Athletics practice proved that the more complex the item, the more difficult technique of the exercises. Fouettes at 720° one of the most difficult types of the fouettes. Its implementation is based on high technology during rotation of the performer. To perform this element not only requires good physical condition of the dancer, but also requires possession correct technique dancer. On the basis corresponding kinematic theory in this study, qualitative analysis and quantitative assessment of fouettes at 720 by the best Chinese dancers. For analysis, was taken the method of stereoscopic images and the theoretical analysis.

  13. Chemical analysis of steel by optical emission spectrometry

    International Nuclear Information System (INIS)

    Hayakawa, M.O.; Kajita, T.; Jeszensky, G.

    1981-01-01

    The development of the chemical analysis for special steels by optical emission spectrometry direct reading method with computer, at the Siderurgica N.S. Aparecida S.A. is presented. Results are presented for the low alloy steels and high speed steel. Also, the contribution of this method to the special steel preparation is commented. (Author) [pt

  14. Physico-chemical analysis and sensory evaluation of bread ...

    African Journals Online (AJOL)

    This study carried out the physico-chemical analysis and sensory evaluation of bread produced using different indigenous yeast isolates in order to offer an insight into the overall quality of the bread. Four (4) different yeast species were isolated from sweet orange, pineapple and palm wine. The yeasts were characterized ...

  15. Chemical and antimicrobial analysis of husk fiber aqueous extract ...

    African Journals Online (AJOL)

    Chemical and antimicrobial analysis of husk fiber aqueous extract from Cocos nucifera L. Davi Oliveira e Silva, Gabriel Rocha Martins, Antônio Jorge Ribeiro da Silva, Daniela Sales Alviano, Rodrigo Pires Nascimento, Maria Auxiliadora Coelho Kaplan, Celuta Sales Alviano ...

  16. Bark chemical analysis explains selective bark damage by rodents

    Czech Academy of Sciences Publication Activity Database

    Heroldová, Marta; Jánová, Eva; Suchomel, J.; Purchart, L.; Homolka, Miloslav

    2009-01-01

    Roč. 2, č. 2 (2009), s. 137-140 ISSN 1803-2451 R&D Projects: GA MZe QH72075 Institutional research plan: CEZ:AV0Z60930519 Keywords : bark damage * bark selection * bark chemical analysis * rowan * beech * spruce * mountain forest regeneration Subject RIV: GK - Forestry

  17. Trends in grazing emission x-ray analysis techniques

    International Nuclear Information System (INIS)

    Grieken, R. van; Tsuji, K.; Injuk, J.

    2000-01-01

    then, the detection limits imposed by the semiconductor industry roadmap can probably not be obtained by tube-excited GEXRF. Th perspectives for tube-excited GE-XRF are thus rather poor. Future developments imply the combination of GEXRF with synchrotron radiation excitation. Grazing-emission particle-induced X-ray emission (GE-PIXE) suffers of similar quantification Problems for material deposited on a carrier, but it makes PIXE a surface-sensitive technique, while normally the protons penetrate some tens of μm in the sample. Similarly, grazing-emission electron probe micro-analysis (GE-EPNIA) allows to selectively analyze particles on a flat carrier, allows surface sensitivities in the nm rather than μ range, and yields, in principle, a spatial resolution for chemical analysis similar to the size of the impinging electron beam, rather than of the electron-excited volume. Both GE-PIXE and GE-EPMA need to be explored more fully in the near future. (author)

  18. Romanian medieval earring analysis by X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Therese, Laurent; Guillot, Philippe; Muja, Cristina

    2011-01-01

    Full text: Several instrumental techniques of elemental analysis are now used for the characterization of archaeological materials. The combination between archaeological and analytical information can provide significant knowledge on the constituting material origin, heritage authentication and restoration, provenance, migration, social interaction and exchange. Surface mapping techniques such as X-Ray Fluorescence have become a powerful tool for obtaining qualitative and semi-quantitative information about the chemical composition of cultural heritage materials, including metallic archaeological objects. In this study, the material comes from the Middle Age cemetery of Feldioara (Romania). The excavation of the site located between the evangelical church and the parsonage led to the discovery of several funeral artifacts in 18 graves among a total of 127 excavated. Even if the inventory was quite poor, some of the objects helped in establishing the chronology. Six anonymous Hungarian denarii (silver coins) were attributed to Geza II (1141-1161) and Stefan III (1162-1172), placing the cemetery in the second half of the XII century. This period was also confirmed by three loop shaped earrings with the end in 'S' form (one small and two large earrings). The small earring was found during the excavation in grave number 86, while the two others were discovered together in grave number 113. The anthropological study shown that skeletons excavated from graves 86 and 113 belonged respectively to a child (1 individual, medium level preservation, 9 months +/- 3 months) and to an adult (1 individual). In this work, elemental mapping were obtained by X-ray fluorescence (XRF) technique from Jobin Yvon Horiba XGT-5000 instrument offering detailed elemental images with a spatial resolution of 100μm. The analysis revealed that the earrings were composed of copper, zinc and tin as major elements. Minor elements were also determined. The comparison between the two large earrings

  19. Romanian medieval earring analysis by X-ray fluorescence technique

    Energy Technology Data Exchange (ETDEWEB)

    Therese, Laurent; Guillot, Philippe, E-mail: philippe.guillot@univ-jfc.fr [Laboratoire Diagnostics des Plasmas, CUFR J.F.C, Albi (France); Muja, Cristina [Laboratoire Diagnostics des Plasmas, CUFR J.F.C, Albi (France); Faculty of Biology, University of Bucharest (Romania); Vasile Parvan Institute of Archaeology, Bucharest, (Romania)

    2011-07-01

    Full text: Several instrumental techniques of elemental analysis are now used for the characterization of archaeological materials. The combination between archaeological and analytical information can provide significant knowledge on the constituting material origin, heritage authentication and restoration, provenance, migration, social interaction and exchange. Surface mapping techniques such as X-Ray Fluorescence have become a powerful tool for obtaining qualitative and semi-quantitative information about the chemical composition of cultural heritage materials, including metallic archaeological objects. In this study, the material comes from the Middle Age cemetery of Feldioara (Romania). The excavation of the site located between the evangelical church and the parsonage led to the discovery of several funeral artifacts in 18 graves among a total of 127 excavated. Even if the inventory was quite poor, some of the objects helped in establishing the chronology. Six anonymous Hungarian denarii (silver coins) were attributed to Geza II (1141-1161) and Stefan III (1162-1172), placing the cemetery in the second half of the XII century. This period was also confirmed by three loop shaped earrings with the end in 'S' form (one small and two large earrings). The small earring was found during the excavation in grave number 86, while the two others were discovered together in grave number 113. The anthropological study shown that skeletons excavated from graves 86 and 113 belonged respectively to a child (1 individual, medium level preservation, 9 months +/- 3 months) and to an adult (1 individual). In this work, elemental mapping were obtained by X-ray fluorescence (XRF) technique from Jobin Yvon Horiba XGT-5000 instrument offering detailed elemental images with a spatial resolution of 100{mu}m. The analysis revealed that the earrings were composed of copper, zinc and tin as major elements. Minor elements were also determined. The comparison between the two

  20. Chemical analysis of bleach and hydroxide-based solutions after decontamination of the chemical warfare agent O-ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX).

    Science.gov (United States)

    Hopkins, F B; Gravett, M R; Self, A J; Wang, M; Chua, Hoe-Chee; Hoe-Chee, C; Lee, H S Nancy; Sim, N Lee Hoi; Jones, J T A; Timperley, C M; Riches, J R

    2014-08-01

    Detailed chemical analysis of solutions used to decontaminate chemical warfare agents can be used to support verification and forensic attribution. Decontamination solutions are amongst the most difficult matrices for chemical analysis because of their corrosive and potentially emulsion-based nature. Consequently, there are relatively few publications that report their detailed chemical analysis. This paper describes the application of modern analytical techniques to the analysis of decontamination solutions following decontamination of the chemical warfare agent O-ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX). We confirm the formation of N,N-diisopropylformamide and N,N-diisopropylamine following decontamination of VX with hypochlorite-based solution, whereas they were not detected in extracts of hydroxide-based decontamination solutions by nuclear magnetic resonance (NMR) spectroscopy or gas chromatography-mass spectrometry. We report the electron ionisation and chemical ionisation mass spectroscopic details, retention indices, and NMR spectra of N,N-diisopropylformamide and N,N-diisopropylamine, as well as analytical methods suitable for their analysis and identification in solvent extracts and decontamination residues.

  1. Thermal and Chemical Characterization of Non-Metallic Materials Using Coupled Thermogravimetric Analysis and Infrared Spectroscopy

    Science.gov (United States)

    Huff, Timothy L.

    2002-01-01

    Thermogravimetric analysis (TGA) is widely employed in the thermal characterization of non-metallic materials, yielding valuable information on decomposition characteristics of a sample over a wide temperature range. However, a potential wealth of chemical information is lost during the process, with the evolving gases generated during thermal decomposition escaping through the exhaust line. Fourier Transform-Infrared spectroscopy (FT-IR) is a powerful analytical technique for determining many chemical constituents while in any material state, in this application, the gas phase. By linking these two techniques, evolving gases generated during the TGA process are directed into an appropriately equipped infrared spectrometer for chemical speciation. Consequently, both thermal decomposition and chemical characterization of a material may be obtained in a single sample run. In practice, a heated transfer line is employed to connect the two instruments while a purge gas stream directs the evolving gases into the FT-IR. The purge gas can be either high purity air or an inert gas such as nitrogen to allow oxidative and pyrolytic processes to be examined, respectively. The FT-IR data is collected realtime, allowing continuous monitoring of chemical compositional changes over the course of thermal decomposition. Using this coupled technique, an array of diverse materials has been examined, including composites, plastics, rubber, fiberglass epoxy resins, polycarbonates, silicones, lubricants and fluorocarbon materials. The benefit of combining these two methodologies is of particular importance in the aerospace community, where newly developing materials have little available data with which to refer. By providing both thermal and chemical data simultaneously, a more definitive and comprehensive characterization of the material is possible. Additionally, this procedure has been found to be a viable screening technique for certain materials, with the generated data useful in

  2. Synthesis of carbon nanotubes using the cobalt nanocatalyst by thermal chemical vapor deposition technique

    Energy Technology Data Exchange (ETDEWEB)

    Madani, S.S. [Department of Chemistry, Science and Research Branch, Islamic Azad University, Tehran (Iran, Islamic Republic of); Zare, K. [Department of Chemistry, Science and Research Branch, Islamic Azad University, Tehran (Iran, Islamic Republic of); Department of Chemistry, Shahid Beheshti University, Tehran (Iran, Islamic Republic of); Ghoranneviss, M. [Plasma Physics Research Center, Science and Research Branch, Islamic Azad University, Tehran (Iran, Islamic Republic of); Salar Elahi, A., E-mail: Salari_phy@yahoo.com [Plasma Physics Research Center, Science and Research Branch, Islamic Azad University, Tehran (Iran, Islamic Republic of)

    2015-11-05

    The three main synthesis methods of Carbon nanotubes (CNTs) are the arc discharge, the laser ablation and the chemical vapour deposition (CVD) with a special regard to the latter one. CNTs were produced on a silicon wafer by Thermal Chemical Vapor Deposition (TCVD) using acetylene as a carbon source, cobalt as a catalyst and ammonia as a reactive gas. The DC-sputtering system was used to prepare cobalt thin films on Si substrates. A series of experiments was carried out to investigate the effects of reaction temperature and deposition time on the synthesis of the nanotubes. The deposition time was selected as 15 and 25 min for all growth temperatures. Energy Dispersive X-ray (EDX) measurements were used to investigate the elemental composition of the Co nanocatalyst deposited on Si substrates. Atomic Force Microscopy (AFM) was used to characterize the surface topography of the Co nanocatalyst deposited on Si substrates. The as-grown CNTs were characterized under Field Emission Scanning Electron Microscopy (FESEM) to study the morphological properties of CNTs. Also, the grown CNTs have been investigated by High Resolution Transmission Electron Microscopy (HRTEM) and Raman spectroscopy. The results demonstrated that increasing the temperature leads to increasing the diameter of CNTs. The ideal reaction temperature was 850 °C and the deposition time was 15 min. - Graphical abstract: FESEM images of CNTs grown on the cobalt catalyst at growth temperatures of (a) 850 °C, (b) 900 °C, (c) 950 °C and (d) 1000 °C during the deposition time of 15 min. - Highlights: • Carbon nanotubes (CNTs) were produced on a silicon wafer by TCVD technique. • EDX and AFM were used to investigate the elemental composition and surface topography. • FESEM was used to study the morphological properties of CNTs. • The grown CNTs have been investigated by HRTEM and Raman spectroscopy.

  3. Recent Development in Optical Chemical Sensors Coupling with Flow Injection Analysis

    Directory of Open Access Journals (Sweden)

    Fuensanta Sánchez Rojas

    2006-10-01

    Full Text Available Optical techniques for chemical analysis are well established and sensors based on thesetechniques are now attracting considerable attention because of their importance in applications suchas environmental monitoring, biomedical sensing, and industrial process control. On the other hand,flow injection analysis (FIA is advisable for the rapid analysis of microliter volume samples and canbe interfaced directly to the chemical process. The FIA has become a widespread automatic analyticalmethod for more reasons; mainly due to the simplicity and low cost of the setups, their versatility, andease of assembling. In this paper, an overview of flow injection determinations by using opticalchemical sensors is provided, and instrumentation, sensor design, and applications are discussed. Thiswork summarizes the most relevant manuscripts from 1980 to date referred to analysis using opticalchemical sensors in FIA.

  4. Nuclear techniques for analysis of coal for calorific value, ash and moisture

    International Nuclear Information System (INIS)

    Dains, Margaret

    1976-03-01

    This bibliography includes references on nuclear techniques for analysis of coal for calorific value, ash and moisture content. As the search was directed particularly towards measurement of the ash content of coal using x- and gamma-ray methods, references covering only β-ray techniques have been placed in a separate section. References from Chemical Abstracts prior vol.62 (1965) do not cite the language of the original article. The language of the original has been given for all other articles not in English. (author)

  5. Neutron activation analysis of high-purity iron in comparison with chemical analysis

    International Nuclear Information System (INIS)

    Kinomura, Atsushi; Horino, Yuji; Takaki, Seiichi; Abiko, Kenji

    2000-01-01

    Neutron activation analysis of iron samples of three different purity levels has been performed and compared with chemical analysis for 30 metallic and metalloid impurity elements. The concentration of As, Cl, Cu, Sb and V detected by neutron activation analysis was mostly in agreement with that obtained by chemical analysis. The sensitivity limits of neutron activation analysis of three kinds of iron samples were calculated and found to be reasonable compared with measured values or detection limits of chemical analysis; however, most of them were above the detection limits of chemical analysis. Graphite-shielded irradiation to suppress fast neutron reactions was effective for Mn analysis without decreasing sensitivity to the other impurity elements. (author)

  6. Effect of Different Catalyst Deposition Technique on Aligned Multiwalled Carbon Nanotubes Grown by Thermal Chemical Vapor Deposition

    Directory of Open Access Journals (Sweden)

    Mohamed Shuaib Mohamed Saheed

    2014-01-01

    Full Text Available The paper reported the investigation of the substrate preparation technique involving deposition of iron catalyst by electron beam evaporation and ferrocene vaporization in order to produce vertically aligned multiwalled carbon nanotubes array needed for fabrication of tailored devices. Prior to the growth at 700°C in ethylene, silicon dioxide coated silicon substrate was prepared by depositing alumina followed by iron using two different methods as described earlier. Characterization analysis revealed that aligned multiwalled carbon nanotubes array of 107.9 µm thickness grown by thermal chemical vapor deposition technique can only be achieved for the sample with iron deposited using ferrocene vaporization. The thick layer of partially oxidized iron film can prevent the deactivation of catalyst and thus is able to sustain the growth. It also increases the rate of permeation of the hydrocarbon gas into the catalyst particles and prevents agglomeration at the growth temperature. Combination of alumina-iron layer provides an efficient growth of high density multiwalled carbon nanotubes array with the steady growth rate of 3.6 µm per minute for the first 12 minutes and dropped by half after 40 minutes. Thicker and uniform iron catalyst film obtained from ferrocene vaporization is attributed to the multidirectional deposition of particles in the gaseous form.

  7. Activation and chemical analysis of drinking water from shallow aquifers

    International Nuclear Information System (INIS)

    Sharma, H.K.; Mittal, V.K.; Sahota, H.S.

    1991-01-01

    In most of the Indian cities drinking water is drawn from shallow aqiufers with the help of hand pumps. These shallow aquifers get easilyl polluted. In the present work we have measured 20 trace elements using Neutron Activation Analysis (NAA) and 8 chemical parameters using standard chemical methods of drinking water drawn from Rajpura city. It was found that almost all water samples are highly polluted. We attribute this to unplaned disposal of industrial and domestic waste over a period of many decades. (author) 11 refs.; 1 fig.; 1 tab

  8. Activation analysis. A basis for chemical similarity and classification

    Energy Technology Data Exchange (ETDEWEB)

    Beeck, J OP de [Ghent Rijksuniversiteit (Belgium). Instituut voor Kernwetenschappen

    1977-01-01

    It is shown that activation analysis is especially suited to serve as a basis for determining the chemical similarity between samples defined by their trace-element concentration patterns. The general problem of classification and identification is discussed. The nature of possible classification structures and their appropriate clustering strategies is considered. A practical computer method is suggested and its application as well as the graphical representation of classification results are given. The possibility for classification using information theory is mentioned. Classification of chemical elements is discussed and practically realized after Hadamard transformation of the concentration variation patterns in a series of samples.

  9. Chemical analysis of plasma-assisted antimicrobial treatment on cotton

    International Nuclear Information System (INIS)

    Kan, C W; Lam, Y L; Yuen, C W M; Luximon, A; Lau, K W; Chen, K S

    2013-01-01

    This paper explores the use of plasma treatment as a pretreatment process to assist the application of antimicrobial process on cotton fabric with good functional effect. In this paper, antimicrobial finishing agent, Microfresh Liquid Formulation 9200-200 (MF), and a binder (polyurethane dispersion, Microban Liquid Formulation R10800-0, MB) will be used for treating the cotton fabric for improving the antimicrobial property and pre-treatment of cotton fabric by plasma under atmospheric pressure will be employed to improve loading of chemical agents. The chemical analysis of the treated cotton fabric will be conducted by Fourier transform Infrared Spectroscopy.

  10. Nuclear analysis techniques as a component of thermoluminescence dating

    Energy Technology Data Exchange (ETDEWEB)

    Prescott, J.R.; Hutton, J.T.; Habermehl, M.A. [Adelaide Univ., SA (Australia); Van Moort, J. [Tasmania Univ., Sandy Bay, TAS (Australia)

    1996-12-31

    In luminescence dating, an age is found by first measuring dose accumulated since the event being dated, then dividing by the annual dose rate. Analyses of minor and trace elements performed by nuclear techniques have long formed an essential component of dating. Results from some Australian sites are reported to illustrate the application of nuclear techniques of analysis in this context. In particular, a variety of methods for finding dose rates are compared, an example of a site where radioactive disequilibrium is significant and a brief summary is given of a problem which was not resolved by nuclear techniques. 5 refs., 2 tabs.

  11. Nuclear analysis techniques as a component of thermoluminescence dating

    Energy Technology Data Exchange (ETDEWEB)

    Prescott, J R; Hutton, J T; Habermehl, M A [Adelaide Univ., SA (Australia); Van Moort, J [Tasmania Univ., Sandy Bay, TAS (Australia)

    1997-12-31

    In luminescence dating, an age is found by first measuring dose accumulated since the event being dated, then dividing by the annual dose rate. Analyses of minor and trace elements performed by nuclear techniques have long formed an essential component of dating. Results from some Australian sites are reported to illustrate the application of nuclear techniques of analysis in this context. In particular, a variety of methods for finding dose rates are compared, an example of a site where radioactive disequilibrium is significant and a brief summary is given of a problem which was not resolved by nuclear techniques. 5 refs., 2 tabs.

  12. Application of pattern recognition techniques to crime analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bender, C.F.; Cox, L.A. Jr.; Chappell, G.A.

    1976-08-15

    The initial goal was to evaluate the capabilities of current pattern recognition techniques when applied to existing computerized crime data. Performance was to be evaluated both in terms of the system's capability to predict crimes and to optimize police manpower allocation. A relation was sought to predict the crime's susceptibility to solution, based on knowledge of the crime type, location, time, etc. The preliminary results of this work are discussed. They indicate that automatic crime analysis involving pattern recognition techniques is feasible, and that efforts to determine optimum variables and techniques are warranted. 47 figures (RWR)

  13. Deconvolution-based resolution enhancement of chemical ice core records obtained by continuous flow analysis

    DEFF Research Database (Denmark)

    Rasmussen, Sune Olander; Andersen, Katrine K.; Johnsen, Sigfus Johann

    2005-01-01

    Continuous flow analysis (CFA) has become a popular measuring technique for obtaining high-resolution chemical ice core records due to an attractive combination of measuring speed and resolution. However, when analyzing the deeper sections of ice cores or cores from low-accumulation areas...... of the data for high-resolution studies such as annual layer counting. The presented method uses deconvolution techniques and is robust to the presence of noise in the measurements. If integrated into the data processing, it requires no additional data collection. The method is applied to selected ice core...

  14. Applications of Electromigration Techniques: Applications of Electromigration Techniques in Food Analysis

    Science.gov (United States)

    Wieczorek, Piotr; Ligor, Magdalena; Buszewski, Bogusław

    Electromigration techniques, including capillary electrophoresis (CE), are widely used for separation and identification of compounds present in food products. These techniques may also be considered as alternate and complementary with respect to commonly used analytical techniques, such as high-performance liquid chromatography (HPLC), or gas chromatography (GC). Applications of CE concern the determination of high-molecular compounds, like polyphenols, including flavonoids, pigments, vitamins, food additives (preservatives, antioxidants, sweeteners, artificial pigments) are presented. Also, the method developed for the determination of proteins and peptides composed of amino acids, which are basic components of food products, are studied. Other substances such as carbohydrates, nucleic acids, biogenic amines, natural toxins, and other contaminations including pesticides and antibiotics are discussed. The possibility of CE application in food control laboratories, where analysis of the composition of food and food products are conducted, is of great importance. CE technique may be used during the control of technological processes in the food industry and for the identification of numerous compounds present in food. Due to the numerous advantages of the CE technique it is successfully used in routine food analysis.

  15. Review and classification of variability analysis techniques with clinical applications.

    Science.gov (United States)

    Bravi, Andrea; Longtin, André; Seely, Andrew J E

    2011-10-10

    Analysis of patterns of variation of time-series, termed variability analysis, represents a rapidly evolving discipline with increasing applications in different fields of science. In medicine and in particular critical care, efforts have focussed on evaluating the clinical utility of variability. However, the growth and complexity of techniques applicable to this field have made interpretation and understanding of variability more challenging. Our objective is to provide an updated review of variability analysis techniques suitable for clinical applications. We review more than 70 variability techniques, providing for each technique a brief description of the underlying theory and assumptions, together with a summary of clinical applications. We propose a revised classification for the domains of variability techniques, which include statistical, geometric, energetic, informational, and invariant. We discuss the process of calculation, often necessitating a mathematical transform of the time-series. Our aims are to summarize a broad literature, promote a shared vocabulary that would improve the exchange of ideas, and the analyses of the results between different studies. We conclude with challenges for the evolving science of variability analysis.

  16. Review and classification of variability analysis techniques with clinical applications

    Science.gov (United States)

    2011-01-01

    Analysis of patterns of variation of time-series, termed variability analysis, represents a rapidly evolving discipline with increasing applications in different fields of science. In medicine and in particular critical care, efforts have focussed on evaluating the clinical utility of variability. However, the growth and complexity of techniques applicable to this field have made interpretation and understanding of variability more challenging. Our objective is to provide an updated review of variability analysis techniques suitable for clinical applications. We review more than 70 variability techniques, providing for each technique a brief description of the underlying theory and assumptions, together with a summary of clinical applications. We propose a revised classification for the domains of variability techniques, which include statistical, geometric, energetic, informational, and invariant. We discuss the process of calculation, often necessitating a mathematical transform of the time-series. Our aims are to summarize a broad literature, promote a shared vocabulary that would improve the exchange of ideas, and the analyses of the results between different studies. We conclude with challenges for the evolving science of variability analysis. PMID:21985357

  17. Molecular structure and spectroscopic characterization of Carbamazepine with experimental techniques and DFT quantum chemical calculations

    Science.gov (United States)

    Suhasini, M.; Sailatha, E.; Gunasekaran, S.; Ramkumaar, G. R.

    2015-04-01

    A systematic vibrational spectroscopic assignment and analysis of Carbamazepine has been carried out by using FT-IR, FT-Raman and UV spectral data. The vibrational analysis were aided by electronic structure calculations - ab initio (RHF) and hybrid density functional methods (B3LYP) performed with standard basis set 6-31G(d,p). Molecular equilibrium geometries, electronic energies, natural bond order analysis, harmonic vibrational frequencies and IR intensities have been computed. A detailed interpretation of the vibrational spectra of the molecule has been made on the basis of the calculated Potential Energy Distribution (PED) by VEDA program. UV-visible spectrum of the compound was also recorded and the electronic properties, such as HOMO and LUMO energies and λmax were determined by HF/6-311++G(d,p) Time-Dependent method. The thermodynamic functions of the title molecule were also performed using the RHF and DFT methods. The restricted Hartree-Fock and density functional theory-based nuclear magnetic resonance (NMR) calculation procedure was also performed, and it was used for assigning the 13C and 1H NMR chemical shifts of Carbamazepine.

  18. Analysis of Atorvastatin in Commercial Solid Drugs using the TT-PIGE Technique

    International Nuclear Information System (INIS)

    Younes, G; Zahraman, K; Nsouli, B; Bejjani, A; Mahmoud, R; El-Yazbi, F

    2008-01-01

    The quantification of the active ingredient (Al) in drugs is a crucial and important step in the drug quality control process. This is usually performed by using wet chemical techniques like LC-MS, UV spectrophotometry and other appropriate organic analytical methods. In the case of an active ingredient contains specific heteroatoms (F, S, Cl), elemental IBA techniques can be explored for molecular quantification. IBA techniques permit the analysis of the sample under solid form, without any laborious sample preparations. This is an advantage when the number of sample is relatively large. In this work, we demonstrate the ability of the Thick Target PIGE technique for rapid and accurate quantification of low concentration AtorvastatinTM in three commercial anti-hyperlipidemic drugs (Lipitor, Liponorm and Storvas). (author)

  19. Analysis of Atorvastatin in Commercial Solid Drugs using the TT-PIGE Technique

    Energy Technology Data Exchange (ETDEWEB)

    Younes, G [Beirut Arab University, Faculty of Science, Chemistry Department Beirut (Lebanon); Zahraman, K; Nsouli, B; Bejjani, A [Lebanese Atomic Energy Commission, National Council for Scientific Research, Beirut (Lebanon); Mahmoud, R; El-Yazbi, F [Beirut Arab University, Faculty of Pharmacy, Department of Pharmaceutical and Analytical Chemistry, Beirut (Lebanon)

    2008-07-01

    The quantification of the active ingredient (Al) in drugs is a crucial and important step in the drug quality control process. This is usually performed by using wet chemical techniques like LC-MS, UV spectrophotometry and other appropriate organic analytical methods. In the case of an active ingredient contains specific heteroatoms (F, S, Cl), elemental IBA techniques can be explored for molecular quantification. IBA techniques permit the analysis of the sample under solid form, without any laborious sample preparations. This is an advantage when the number of sample is relatively large. In this work, we demonstrate the ability of the Thick Target PIGE technique for rapid and accurate quantification of low concentration AtorvastatinTM in three commercial anti-hyperlipidemic drugs (Lipitor, Liponorm and Storvas). (author)

  20. Quantum chemical approaches: semiempirical molecular orbital and hybrid quantum mechanical/molecular mechanical techniques.

    Science.gov (United States)

    Bryce, Richard A; Hillier, Ian H

    2014-01-01

    The use of computational quantum chemical methods to aid drug discovery is surveyed. An overview of the various computational models spanning ab initio, density function theory, semiempirical molecular orbital (MO), and hybrid quantum mechanical (QM)/molecular mechanical (MM) methods is given and their strengths and weaknesses are highlighted, focussing on the challenge of obtaining the accuracy essential for them to make a meaningful contribution to drug discovery. Particular attention is given to hybrid QM/MM and semiempirical MO methods which have the potential to yield the necessary accurate predictions of macromolecular structure and reactivity. These methods are shown to have advanced the study of many aspects of substrate-ligand interactions relevant to drug discovery. Thus, the successful parametrization of semiempirical MO methods and QM/MM methods can be used to model noncovalent substrate-protein interactions, and to lead to improved scoring functions. QM/MM methods can be used in crystal structure refinement and are particularly valuable for modelling covalent protein-ligand interactions and can thus aid the design of transition state analogues. An extensive collection of examples from the areas of metalloenzyme structure, enzyme inhibition, and ligand binding affinities and scoring functions are used to illustrate the power of these techniques.

  1. Preparation of high surface area and high conductivity polyaniline nanoparticles using chemical oxidation polymerization technique

    Science.gov (United States)

    Budi, S.; Yusmaniar; Juliana, A.; Cahyana, U.; Purwanto, A.; Imaduddin, A.; Handoko, E.

    2018-03-01

    In this work, polyaniline nanoparticles were synthesized using a chemical oxidation polymerization technique. The ammonium peroxydisulfate (APS)/aniline ratio, APS dropping time, and polymerization temperature were optimized to increase the surface area and conductivity of the polyaniline.The Fourier-transform infrared (FTIR) spectrum confirmed the formation of emeraldine salt polyaniline. X-ray diffraction (XRD) patterns indicated that amorphous and crystalline phases of the polyaniline were formed with crystallinity less than 40%. Scanning electron microscope (SEM) micrographs showed that the finest nanoparticles with uniform size distribution were obtained at the polymerization temperature of 0°C. A surface area analyzer (SAA) showed that the highest Brunauer-Emmett-Teller surface area (SBET ) of 42.14 m2/gwas obtained from an APS/aniline ratio of 0.75 with a dropping time of 0 s at a polymerization temperature of 0°C. A four-point probe measurement conducted at 75–300K indicated relatively high conductivity of the semiconductor characteristic of the polyaniline.

  2. Studies on the remediation of environment contaminated with radioactive pollutants using the chemical separation technique

    Energy Technology Data Exchange (ETDEWEB)

    Kurotaki, Katsumi; Yonehara, Hidenori; Sahoo, S.K. [National Inst. of Radiological Sciences, Chiba (Japan); Ishii, Toshiaki [National Inst. of Radiological Sciences, Hitachinaka, Ibaraki (Japan). Lab. for Radioecology

    2001-12-01

    Remediation of soil and drinking water contaminated with radioactive nuclides is important for the mitigation of radiation exposure. Then we attempted to construct the remediation system including the dose estimation system using the chemical separation technique to remove pollutants from the environment. The information on air dose rate is important for assessment of risk from the radiation exposure. Then we measured the air dose rate and analysed the relationship between air dose rate and the contamination of soil at the area in Russia (Bryansk district) contaminated by Chernobyl Nuclear Power Plant accident. Moreover, we analysed the soil of Bryansk district on the concentration of rare earth elements, thorium and uranium and on the isotope ratio of strontium. On the other hand, we tried to develop the rapid measurement method of radioactivity of Sr-90 which is one of the dangerous radionuclides, because the method of radioactivity measurement in the literature is too time-consuming. It was reported recently that the molecules containing SH group form the covalent bond with gold atoms at the surface of gold plate and that crown ether compounds have strong affinity to strontium. Then we attempted to synthesize the crown ether containing SH group. In addition, we search the inorganic elements accumulated to special organisms of fishes and other animals in sea in order to find out new reagent for trace elements. Transition metal such as Co, Fe, Ni, Ti, V and Zn were detected from the intracellular granules in the bronchial heart of octopus. (author)

  3. Evaluating chemical extraction techniques for the determination of uranium oxidation state in reduced aquifer sediments

    Science.gov (United States)

    Stoliker, Deborah L.; Campbell, Kate M.; Fox, Patricia M.; Singer, David M.; Kaviani, Nazila; Carey, Minna; Peck, Nicole E.; Barger, John R.; Kent, Douglas B.; Davis, James A.

    2013-01-01

    Extraction techniques utilizing high pH and (bi)carbonate concentrations were evaluated for their efficacy in determining the oxidation state of uranium (U) in reduced sediments collected from Rifle, CO. Differences in dissolved concentrations between oxic and anoxic extractions have been proposed as a means to quantify the U(VI) and U(IV) content of sediments. An additional step was added to anoxic extractions using a strong anion exchange resin to separate dissolved U(IV) and U(VI). X-ray spectroscopy showed that U(IV) in the sediments was present as polymerized precipitates similar to uraninite and/or less ordered U(IV), referred to as non-uraninite U(IV) species associated with biomass (NUSAB). Extractions of sediment containing both uraninite and NUSAB displayed higher dissolved uranium concentrations under oxic than anoxic conditions while extractions of sediment dominated by NUSAB resulted in identical dissolved U concentrations. Dissolved U(IV) was rapidly oxidized under anoxic conditions in all experiments. Uraninite reacted minimally under anoxic conditions but thermodynamic calculations show that its propensity to oxidize is sensitive to solution chemistry and sediment mineralogy. A universal method for quantification of U(IV) and U(VI) in sediments has not yet been developed but the chemical extractions, when combined with solid-phase characterization, have a narrow range of applicability for sediments without U(VI).

  4. Tuning the morphology of metastable MnS films by simple chemical bath deposition technique

    Energy Technology Data Exchange (ETDEWEB)

    Dhandayuthapani, T. [Directorate of Distance Education, Alagappa University, Karaikudi 630004 (India); Girish, M. [Department of Physics, Alagappa University, Karaikudi 630004 (India); Sivakumar, R., E-mail: krsivakumar1979@yahoo.com [Directorate of Distance Education, Alagappa University, Karaikudi 630004 (India); Sanjeeviraja, C. [Department of Physics, Alagappa Chettiar College of Engineering and Technology, Karaikudi 630004 (India); Gopalakrishnan, R. [Department of Physics, Anna University, Chennai 600025 (India)

    2015-10-30

    Graphical abstract: - Highlights: • MnS films with diverse morphological features were prepared without any complexing agent. • The change in morphology of MnS films may be due to the “oriented aggregation”. • The dual role (as sulfur source and structure directing agent) of thiourea was observed. • Sulfur source concentration induced enhancement in the crystallization of films. - Abstract: In the present investigation, we have prepared the spherical particles, almond-like, and cauliflower-like morphological structures of metastable MnS films on glass substrate by chemical bath deposition technique at low temperature without using any complexing or chelating agent. The morphological change of MnS films with molar ratio may be due to the oriented aggregation of adjacent particles. The compositional purity of deposited film was confirmed by the EDAX study. X-ray diffraction and micro-Raman studies confirm the sulfur source concentration induced enhancement in the crystallization of films with metastable MnS phase (zinc-blende β-MnS, and wurtzite γ-MnS). The shift in PL emission peak with molar ratio may be due to the change in optical energy band gap of the MnS, which was further confirmed by the optical absorbance study. The paramagnetic behavior of the sample was confirmed by the M–H plot.

  5. Comparison of the Chemical Composition of “Cystoseira sedoides (Desfontaines C. Agardh” Volatile Compounds Obtained by Different Extraction Techniques

    Directory of Open Access Journals (Sweden)

    Naima Bouzidi

    2016-01-01

    Full Text Available The volatile fraction of the brown alga Cystoseira sedoides (Desfontaines C.Agardh is prepared from the crude extract through the following three extraction methods: Hydrodistillation (HD, focused microwave assisted hydrodistillation (FMAHD and supercritical fluid extraction (SFE. The volatile fractions are analyzed by gas chromatography-flame ionization detector-mass spectrometry (GC-FID-MS, the chemical components are identified on the basis of the comparison of their retention indices with literature and their mass spectra with those reported in commercial databases. The chemical composition of the volatile fractions obtained by different extraction techniques fall into three major chemical classes: fatty acids and derivatives, sesquiterpenes, and hydrocarbons and derivatives. Others Compounds belonging to different chemical classes are found in that chemical composition.

  6. Automated thermal mapping techniques using chromatic image analysis

    Science.gov (United States)

    Buck, Gregory M.

    1989-01-01

    Thermal imaging techniques are introduced using a chromatic image analysis system and temperature sensitive coatings. These techniques are used for thermal mapping and surface heat transfer measurements on aerothermodynamic test models in hypersonic wind tunnels. Measurements are made on complex vehicle configurations in a timely manner and at minimal expense. The image analysis system uses separate wavelength filtered images to analyze surface spectral intensity data. The system was initially developed for quantitative surface temperature mapping using two-color thermographic phosphors but was found useful in interpreting phase change paint and liquid crystal data as well.

  7. Using Machine Learning Techniques in the Analysis of Oceanographic Data

    Science.gov (United States)

    Falcinelli, K. E.; Abuomar, S.

    2017-12-01

    Acoustic Doppler Current Profilers (ADCPs) are oceanographic tools capable of collecting large amounts of current profile data. Using unsupervised machine learning techniques such as principal component analysis, fuzzy c-means clustering, and self-organizing maps, patterns and trends in an ADCP dataset are found. Cluster validity algorithms such as visual assessment of cluster tendency and clustering index are used to determine the optimal number of clusters in the ADCP dataset. These techniques prove to be useful in analysis of ADCP data and demonstrate potential for future use in other oceanographic applications.

  8. Photoluminescence of nc-Si:Er thin films obtained by physical and chemical vapour deposition techniques: The effects of microstructure and chemical composition

    Energy Technology Data Exchange (ETDEWEB)

    Cerqueira, M.F., E-mail: fcerqueira@fisica.uminho.p [Departamento de Fisica, Universidade do Minho, Campus de Gualtar 4710-057 Braga (Portugal); Losurdo, M. [Institute of Inorganic Methodologies and of Plasmas, IMIP-CNR, Via Orabona n.4-70126 Bari (Italy); Stepikhova, M. [Institute for Physics of Microstructures RAS, 603600 Nizhnij Novgorod GSP-105 (Russian Federation); Alpuim, P.; Andres, G. [Departamento de Fisica, Universidade do Minho, Campus de Gualtar 4710-057 Braga (Portugal); Kozanecki, A. [Polish Academy of Sciences, Institute of Physics, PL-02668, Warsaw (Poland); Soares, M.J.; Peres, M. [Departamento de Fisica, Universidade de Aveiro, Campus de Santiago, 3700 Aveiro (Portugal)

    2009-08-31

    Erbium doped nanocrystalline silicon (nc-Si:Er) thin films were produced by reactive magnetron rf sputtering and by Er ion implantation into chemical vapor deposited Si films. The structure and chemical composition of films obtained by the two approaches were studied by micro-Raman scattering, spectroscopic ellipsometry and Rutherford backscattering techniques. Variation of deposition parameters was used to deposit films with different crystalline fraction and crystallite size. Photoluminescence measurements revealed a correlation between film microstructure and the Er{sup 3+} photoluminescence efficiency.

  9. Windows forensic analysis toolkit advanced analysis techniques for Windows 7

    CERN Document Server

    Carvey, Harlan

    2012-01-01

    Now in its third edition, Harlan Carvey has updated "Windows Forensic Analysis Toolkit" to cover Windows 7 systems. The primary focus of this edition is on analyzing Windows 7 systems and on processes using free and open-source tools. The book covers live response, file analysis, malware detection, timeline, and much more. The author presents real-life experiences from the trenches, making the material realistic and showing the why behind the how. New to this edition, the companion and toolkit materials are now hosted online. This material consists of electronic printable checklists, cheat sheets, free custom tools, and walk-through demos. This edition complements "Windows Forensic Analysis Toolkit, 2nd Edition", (ISBN: 9781597494229), which focuses primarily on XP. It includes complete coverage and examples on Windows 7 systems. It contains Lessons from the Field, Case Studies, and War Stories. It features companion online material, including electronic printable checklists, cheat sheets, free custom tools, ...

  10. Chemical analysis of acoustically levitated drops by Raman spectroscopy.

    Science.gov (United States)

    Tuckermann, Rudolf; Puskar, Ljiljana; Zavabeti, Mahta; Sekine, Ryo; McNaughton, Don

    2009-07-01

    An experimental apparatus combining Raman spectroscopy with acoustic levitation, Raman acoustic levitation spectroscopy (RALS), is investigated in the field of physical and chemical analytics. Whereas acoustic levitation enables the contactless handling of microsized samples, Raman spectroscopy offers the advantage of a noninvasive method without complex sample preparation. After carrying out some systematic tests to probe the sensitivity of the technique to drop size, shape, and position, RALS has been successfully applied in monitoring sample dilution and preconcentration, evaporation, crystallization, an acid-base reaction, and analytes in a surface-enhanced Raman spectroscopy colloidal suspension.

  11. Conference on Techniques of Nuclear and Conventional Analysis and Applications

    International Nuclear Information System (INIS)

    2012-01-01

    Full text : With their wide scope, particularly in the areas of environment, geology, mining, industry and life sciences; analysis techniques are of great importance in research as fundamental and applied. The Conference on Techniques for Nuclear and Conventional Analysis and Applications (TANCA) are Registered in the national strategy of opening of the University and national research centers on their local, national and international levels. This conference aims to: Promoting nuclear and conventional analytical techniques; Contribute to the creation of synergy between the different players involved in these techniques include, Universities, Research Organizations, Regulatory Authorities, Economic Operators, NGOs and others; Inform and educate potential users of the performance of these techniques; Strengthen exchanges and links between researchers, industry and policy makers; Implement a program of inter-laboratory comparison between Moroccan one hand, and their foreign counterparts on the other; Contribute to the research training of doctoral students and postdoctoral scholars. Given the relevance and importance of the issues related to environment and impact on cultural heritage, this fourth edition of TANCA is devoted to the application of analytical techniques for conventional and nuclear Questions ied to environment and its impact on cultural heritage.

  12. Implementation of the NMR CHEmical Shift Covariance Analysis (CHESCA): A Chemical Biologist's Approach to Allostery.

    Science.gov (United States)

    Boulton, Stephen; Selvaratnam, Rajeevan; Ahmed, Rashik; Melacini, Giuseppe

    2018-01-01

    Mapping allosteric sites is emerging as one of the central challenges in physiology, pathology, and pharmacology. Nuclear Magnetic Resonance (NMR) spectroscopy is ideally suited to map allosteric sites, given its ability to sense at atomic resolution the dynamics underlying allostery. Here, we focus specifically on the NMR CHEmical Shift Covariance Analysis (CHESCA), in which allosteric systems are interrogated through a targeted library of perturbations (e.g., mutations and/or analogs of the allosteric effector ligand). The atomic resolution readout for the response to such perturbation library is provided by NMR chemical shifts. These are then subject to statistical correlation and covariance analyses resulting in clusters of allosterically coupled residues that exhibit concerted responses to the common set of perturbations. This chapter provides a description of how each step in the CHESCA is implemented, starting from the selection of the perturbation library and ending with an overview of different clustering options.

  13. The application of value analysis techniques for complex problems

    International Nuclear Information System (INIS)

    Chiquelin, W.R.; Cossel, S.C.; De Jong, V.J.; Halverson, T.W.

    1986-01-01

    This paper discusses the application of the Value Analysis technique to the transuranic package transporter (TRUPACT). A team representing five different companies or organizations with diverse technical backgrounds was formed to analyze and recommend improvements. The results were a 38% systems-wide savings, if incorporated, and a shipping container which is volumetrically and payload efficient as well as user friendly. The Value Analysis technique is a proven tool widely used in many diverse areas both in the government and the private sector. Value Analysis uses functional diagramming of a piece of equipment or process to discretely identify every facet of the item being analyzed. A standard set of questions is then asked: What is it?, What does it do?, What does it cost?, What else will do the task?, and What would that cost? Using logic and a disciplined approach, the result of the Value Analysis performs the necessary functions at a high quality and the lowest overall cost

  14. Application of energy dispersive x-ray techniques for water analysis

    International Nuclear Information System (INIS)

    Funtua, I. I.

    2000-07-01

    Energy dispersive x-ray fluorescence (EDXRF) is a class of emission spectroscopic techniques that depends upon the emission of characteristic x-rays following excitation of the atomic electron energy levels by tube or isotopic source x-rays. The technique has found wide range of applications that include determination of chemical elements of water and water pollutants. Three EDXRF systems, the isotopic source, secondary target and total reflection (TXRF) are available at the Centre for Energy research and Training. These systems have been applied for the analysis of sediments, suspensions, ground water, river and rainwater. The isotopic source is based on 55 Fe, 109 Cd and 241 Am excitations while the secondary target and the total reflection are utilizing a Mo x-ray tube. Sample preparation requirements for water analysis range from physical and chemical pre-concentration steps to direct analysis and elements from Al to U can be determined with these systems. The EDXRF techniques, TXRF in particular with its multielement capability, low detection limit and possibility of direct analysis for water have competitive edge over the traditional methods of atomic absorption and flame photometry

  15. A comparative analysis of soft computing techniques for gene prediction.

    Science.gov (United States)

    Goel, Neelam; Singh, Shailendra; Aseri, Trilok Chand

    2013-07-01

    The rapid growth of genomic sequence data for both human and nonhuman species has made analyzing these sequences, especially predicting genes in them, very important and is currently the focus of many research efforts. Beside its scientific interest in the molecular biology and genomics community, gene prediction is of considerable importance in human health and medicine. A variety of gene prediction techniques have been developed for eukaryotes over the past few years. This article reviews and analyzes the application of certain soft computing techniques in gene prediction. First, the problem of gene prediction and its challenges are described. These are followed by different soft computing techniques along with their application to gene prediction. In addition, a comparative analysis of different soft computing techniques for gene prediction is given. Finally some limitations of the current research activities and future research directions are provided. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. All-Russia conference on chemical analysis of substances and materials. Abstracts of reports

    International Nuclear Information System (INIS)

    2000-01-01

    Collection contains abstracts of reports on chemical analysis of foods, drugs, environmental materials. Methods of chemical analysis used in such regions as chemical control in agriculture, criminology, art and archaeology, biotechnology, geology, chemistry and petrochemistry, metallurgy, metrology are presented. Theoretical, methodological and applied aspects of chemical analysis are considered [ru

  17. Comparing dynamical systems concepts and techniques for biomechanical analysis

    OpenAIRE

    van Emmerik, Richard E.A.; Ducharme, Scott W.; Amado, Avelino C.; Hamill, Joseph

    2016-01-01

    Traditional biomechanical analyses of human movement are generally derived from linear mathematics. While these methods can be useful in many situations, they do not describe behaviors in human systems that are predominately nonlinear. For this reason, nonlinear analysis methods based on a dynamical systems approach have become more prevalent in recent literature. These analysis techniques have provided new insights into how systems (1) maintain pattern stability, (2) transition into new stat...

  18. Reliability Analysis Techniques for Communication Networks in Nuclear Power Plant

    International Nuclear Information System (INIS)

    Lim, T. J.; Jang, S. C.; Kang, H. G.; Kim, M. C.; Eom, H. S.; Lee, H. J.

    2006-09-01

    The objectives of this project is to investigate and study existing reliability analysis techniques for communication networks in order to develop reliability analysis models for nuclear power plant's safety-critical networks. It is necessary to make a comprehensive survey of current methodologies for communication network reliability. Major outputs of this study are design characteristics of safety-critical communication networks, efficient algorithms for quantifying reliability of communication networks, and preliminary models for assessing reliability of safety-critical communication networks

  19. Quantitative analysis of chemical elements in single cells using nuclear microprobe and nano-probe

    International Nuclear Information System (INIS)

    Deves, Guillaume

    2010-01-01

    The study of the role of trace elements at cellular level requires the use of state-of-the-art analytical tools that could achieve enough sensitivity and spatial resolution. We developed a new methodology for the accurate quantification of chemical element distribution in single cells based on a combination of ion beam analysis techniques STIM, PIXE and RBS. The quantification procedure relies on the development of a STIM data analysis software (Paparamborde). Validity of this methodology and limits are discussed here. The method allows the quantification of trace elements (μg/g) with a 19.8 % uncertainty in cellular compartments with mass below 0.1 ng. The main limit of the method lies in the poor number of samples that can be analyzed, due to long irradiation times required and limited access to ion beam analysis facilities. This is the reason why we developed a database for cellular chemical composition capitalization (BDC4). BDC4 has been designed in order to use cellular chemical composition as a tracer for biological activities and is expected to provide in the future reference chemical compositions for any cellular type or compartment. Application of the STIM-PIXE-RBS methodology to the study of nuclear toxicology of cobalt compounds is presented here showing that STIM analysis is absolutely needed when organic mass loss appears during PIXE-RBS irradiation. (author)

  20. Evolution of the sedimentation technique for particle size distribution analysis

    International Nuclear Information System (INIS)

    Maley, R.

    1998-01-01

    After an introduction on the significance of particle size measurements, sedimentation methods are described, with emphasis on the evolution of the gravitational approach. The gravitational technique based on mass determination by X-ray adsorption allows fast analysis by automation and easy data handling, in addition to providing the accuracy required by quality control and research applications [it

  1. Comparative Analysis of Some Techniques in the Biological ...

    African Journals Online (AJOL)

    The experiments involved the simulation of conditions of a major spill by pouring crude oil on the cells from perforated cans and the in-situ bioremediation of the polluted soils using the techniques that consisted in the manipulation of different variables within the soil environment. The analysis of soil characteristics after a ...

  2. Tailored Cloze: Improved with Classical Item Analysis Techniques.

    Science.gov (United States)

    Brown, James Dean

    1988-01-01

    The reliability and validity of a cloze procedure used as an English-as-a-second-language (ESL) test in China were improved by applying traditional item analysis and selection techniques. The 'best' test items were chosen on the basis of item facility and discrimination indices, and were administered as a 'tailored cloze.' 29 references listed.…

  3. The Recoverability of P-Technique Factor Analysis

    Science.gov (United States)

    Molenaar, Peter C. M.; Nesselroade, John R.

    2009-01-01

    It seems that just when we are about to lay P-technique factor analysis finally to rest as obsolete because of newer, more sophisticated multivariate time-series models using latent variables--dynamic factor models--it rears its head to inform us that an obituary may be premature. We present the results of some simulations demonstrating that even…

  4. Regression analysis of a chemical reaction fouling model

    International Nuclear Information System (INIS)

    Vasak, F.; Epstein, N.

    1996-01-01

    A previously reported mathematical model for the initial chemical reaction fouling of a heated tube is critically examined in the light of the experimental data for which it was developed. A regression analysis of the model with respect to that data shows that the reference point upon which the two adjustable parameters of the model were originally based was well chosen, albeit fortuitously. (author). 3 refs., 2 tabs., 2 figs

  5. Gas analysis during the chemical vapor deposition of carbon

    International Nuclear Information System (INIS)

    Lieberman, M.L.; Noles, G.T.

    1973-01-01

    Gas chromatographic analyses were performed during the chemical vapor deposition of carbon in both isothermal and thermal gradient systems. Such data offer insight into the gas phase processes which occur during deposition and the interrelations which exist between gas composition, deposition rate, and resultant structure of the deposit. The results support a carbon CVD model presented previously. The application of chromatographic analysis to research, development, and full-scale facilities is shown. (U.S.)

  6. Cluster analysis to evaluate stable chemical elements and physical-chemical parameters behavior on uranium mining waste

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Wagner de Souza; Py Junior, Delcy de Azevedo; Goncalves, Simone, E-mail: wspereira@inb.gov.br [Unidade de Tratamento de Minerio (UTM/INB), Pocos de Caldas, MG (Brazil). Coordenacao de Protecao Radiologica. Grupo Multidisciplinar de Radioprotecao; Kelecom, Alphonse [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Inst. de Biologia. Lab. de Radiobiologia e Radiometria Pedro Lopes dos Santos; Morais, Gustavo Ferrari de; Campelo, Emanuele Lazzaretti Cordova [Unidade de Tratamento de Minerio (UTM/INB), Pocos de Caldas, MG (Brazil). Coordenacao de Desenvolvimento de Processos; Dores, Luis Augusto de Carvalho Bresser [Unidade de Tratamento de Minerio (UTM/INB), Pocos de Caldas, MG (Brazil). Gerencia de Descomissionamento

    2011-07-01

    The Ore Treating Unit (UTM, in portuguese) is a deactivated uranium mine. A cluster analysis was used to evaluate the behavior of stable chemical elements and physical-chemical parameters in their effluents. The utilization of the cluster analysis proved itself effective in the assessment, allowing the identification of groups of chemical elements, physical-chemical parameters and their joint analysis (elements and parameters). As a result we may assert, based on data analysis, that there is a strong link between calcium and magnesium and between aluminum and rare-earth oxides on UTM's effluents. Sulphate was also identified as strongly linked to total and dissolved solids, and those to electrical conductivity. There were other associations, but not so strongly linked. Further gathering, to seasonal evaluation, are required in order to confirm those analysis. Additional statistical analysis (factor analysis) must be used to try to identify the origin of the identified groups on this analysis. (author)

  7. Cluster analysis to evaluate stable chemical elements and physical-chemical parameters behavior on uranium mining waste

    International Nuclear Information System (INIS)

    Pereira, Wagner de Souza; Py Junior, Delcy de Azevedo; Goncalves, Simone; Kelecom, Alphonse; Morais, Gustavo Ferrari de; Campelo, Emanuele Lazzaretti Cordova; Dores, Luis Augusto de Carvalho Bresser

    2011-01-01

    The Ore Treating Unit (UTM, in portuguese) is a deactivated uranium mine. A cluster analysis was used to evaluate the behavior of stable chemical elements and physical-chemical parameters in their effluents. The utilization of the cluster analysis proved itself effective in the assessment, allowing the identification of groups of chemical elements, physical-chemical parameters and their joint analysis (elements and parameters). As a result we may assert, based on data analysis, that there is a strong link between calcium and magnesium and between aluminum and rare-earth oxides on UTM's effluents. Sulphate was also identified as strongly linked to total and dissolved solids, and those to electrical conductivity. There were other associations, but not so strongly linked. Further gathering, to seasonal evaluation, are required in order to confirm those analysis. Additional statistical analysis (factor analysis) must be used to try to identify the origin of the identified groups on this analysis. (author)

  8. Anglo-Saxon animal husbandry techniques revealed though isotope and chemical variations in cattle teeth

    International Nuclear Information System (INIS)

    Evans, J.A.; Tatham, S.; Chenery, S.R.; Chenery, C.A.

    2007-01-01

    The Sr concentration and isotope composition of tooth enamel from domesticated animals from two neighbouring Anglo-Saxon settlements, at Empingham (6-7th century) and Ketton (10-12th century) in Rutland, central England, are compared both with each other, and with associated human populations. Data from the Empingham II site form discrete fields in Sr concentration and isotope composition space for cattle, pig and sheep with a partial overlap of the human and pig fields. By contrast there is significant overlap in all the animal and human data fields from the Ketton site. The differences in data distribution between the two sites are attributed to animal husbandry techniques, as the surface geology of the two areas is very similar, implying geological factors are an unlikely cause of the difference. It is suggested that the grazing and feeding patterns of animals at the Empingham II site were controlled and restricted, whereas at the Ketton site the animals grazed and foraged freely over a common area. Strontium isotope variation within cattle molars from the two settlements show marked differences that reflect the nature of their feeding and rearing. The enamel from a cattle molar from the Empingham II site has a well-defined, systematic variation of Sr isotope composition with Sr concentration, whereas no such patterns exist in a comparable cattle molar from Ketton. Chemical and O isotope variations in the cattle tooth from Empingham II show sympathetic variation of Sr and Ba concentrations with Sr isotope composition from cusp to cervix. The cusp has higher Sr and Ba concentrations log (Sr/Ca) ratio of -3.1 and 87 Sr/ 86 Sr ratio of 0.71151 where as the cervical region of the enamel has log (Sr/Ca) = -3.3 and 87 Sr/ 86 Sr = 0.71061

  9. Anglo-Saxon animal husbandry techniques revealed though isotope and chemical variations in cattle teeth

    Energy Technology Data Exchange (ETDEWEB)

    Evans, J.A. [NERC Isotope Geosciences Laboratory, BGS, Keyworth, Nottingham NG12 5GG (United Kingdom)], E-mail: je@nigl.nerc.ac.uk; Tatham, S. [School of Archaeology and Ancient History, University of Leicester, Leicester LE1 7RH (United Kingdom); Chenery, S.R. [British Geological Survey, Keyworth, Nottingham NG12 5GG (United Kingdom); Chenery, C.A. [NERC Isotope Geosciences Laboratory, BGS, Keyworth, Nottingham NG12 5GG (United Kingdom)

    2007-09-15

    The Sr concentration and isotope composition of tooth enamel from domesticated animals from two neighbouring Anglo-Saxon settlements, at Empingham (6-7th century) and Ketton (10-12th century) in Rutland, central England, are compared both with each other, and with associated human populations. Data from the Empingham II site form discrete fields in Sr concentration and isotope composition space for cattle, pig and sheep with a partial overlap of the human and pig fields. By contrast there is significant overlap in all the animal and human data fields from the Ketton site. The differences in data distribution between the two sites are attributed to animal husbandry techniques, as the surface geology of the two areas is very similar, implying geological factors are an unlikely cause of the difference. It is suggested that the grazing and feeding patterns of animals at the Empingham II site were controlled and restricted, whereas at the Ketton site the animals grazed and foraged freely over a common area. Strontium isotope variation within cattle molars from the two settlements show marked differences that reflect the nature of their feeding and rearing. The enamel from a cattle molar from the Empingham II site has a well-defined, systematic variation of Sr isotope composition with Sr concentration, whereas no such patterns exist in a comparable cattle molar from Ketton. Chemical and O isotope variations in the cattle tooth from Empingham II show sympathetic variation of Sr and Ba concentrations with Sr isotope composition from cusp to cervix. The cusp has higher Sr and Ba concentrations log (Sr/Ca) ratio of -3.1 and {sup 87}Sr/{sup 86}Sr ratio of 0.71151 where as the cervical region of the enamel has log (Sr/Ca) = -3.3 and {sup 87}Sr/{sup 86}Sr = 0.71061.

  10. Shotgun lipidomic analysis of chemically sulfated sterols compromises analytical sensitivity

    DEFF Research Database (Denmark)

    Casanovas, Albert; Hannibal-Bach, Hans Kristian; Jensen, Ole Nørregaard

    2014-01-01

    Shotgun lipidomics affords comprehensive and quantitative analysis of lipid species in cells and tissues at high-throughput [1 5]. The methodology is based on direct infusion of lipid extracts by electrospray ionization (ESI) combined with tandem mass spectrometry (MS/MS) and/or high resolution F...... low ionization efficiency in ESI [7]. For this reason, chemical derivatization procedures including acetylation [8] or sulfation [9] are commonly implemented to facilitate ionization, detection and quantification of sterols for global lipidome analysis [1-3, 10]....

  11. Chemical Differentiation of Osseous, Dental, and Non-skeletal Materials in Forensic Anthropology using Elemental Analysis.

    Science.gov (United States)

    Zimmerman, Heather A; Meizel-Lambert, Cayli J; Schultz, John J; Sigman, Michael E

    2015-03-01

    Forensic anthropologists are generally able to identify skeletal materials (bone and tooth) using gross anatomical features; however, highly fragmented or taphonomically altered materials may be problematic to identify. Several chemical analysis techniques have been shown to be reliable laboratory methods that can be used to determine if questionable fragments are osseous, dental, or non-skeletal in nature. The purpose of this review is to provide a detailed background of chemical analysis techniques focusing on elemental compositions that have been assessed for use in differentiating osseous, dental, and non-skeletal materials. More recently, chemical analysis studies have also focused on using the elemental composition of osseous/dental materials to evaluate species and provide individual discrimination, but have generally been successful only in small, closed groups, limiting their use forensically. Despite significant advances incorporating a variety of instruments, including handheld devices, further research is necessary to address issues in standardization, error rates, and sample size/diversity. Copyright © 2014 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  12. Study of analysis techniques of thermoluminescent dosimeters response

    International Nuclear Information System (INIS)

    Castro, Walber Amorim

    2002-01-01

    The Personal Monitoring Service of the Centro Regional de Ciencias Nucleares uses in its dosemeter the TLD 700 material . The TLD's analysis is carried out using a Harshaw-Bicron model 6600 automatic reading system. This system uses dry air instead of the traditional gaseous nitrogen. This innovation brought advantages to the service but introduced uncertainties in the reference of the detectors; one of these was observed for doses below 0,5 mSv. In this work different techniques of analysis of the TLD response were investigated and compared, involving dose values in this interval. These techniques include thermal pre-treatment, and different kinds of the glow curves analysis methods were investigated. Obtained results showed the necessity of developing a specific software that permits the automatic background subtraction for the glow curves for each dosemeter . This software was developed and it bean tested. Preliminary results showed the software increase the response reproducibility. (author)

  13. Sensitivity analysis technique for application to deterministic models

    International Nuclear Information System (INIS)

    Ishigami, T.; Cazzoli, E.; Khatib-Rahbar, M.; Unwin, S.D.

    1987-01-01

    The characterization of sever accident source terms for light water reactors should include consideration of uncertainties. An important element of any uncertainty analysis is an evaluation of the sensitivity of the output probability distributions reflecting source term uncertainties to assumptions regarding the input probability distributions. Historically, response surface methods (RSMs) were developed to replace physical models using, for example, regression techniques, with simplified models for example, regression techniques, with simplified models for extensive calculations. The purpose of this paper is to present a new method for sensitivity analysis that does not utilize RSM, but instead relies directly on the results obtained from the original computer code calculations. The merits of this approach are demonstrated by application of the proposed method to the suppression pool aerosol removal code (SPARC), and the results are compared with those obtained by sensitivity analysis with (a) the code itself, (b) a regression model, and (c) Iman's method

  14. Multivariate Analysis Techniques for Optimal Vision System Design

    DEFF Research Database (Denmark)

    Sharifzadeh, Sara

    The present thesis considers optimization of the spectral vision systems used for quality inspection of food items. The relationship between food quality, vision based techniques and spectral signature are described. The vision instruments for food analysis as well as datasets of the food items...... used in this thesis are described. The methodological strategies are outlined including sparse regression and pre-processing based on feature selection and extraction methods, supervised versus unsupervised analysis and linear versus non-linear approaches. One supervised feature selection algorithm...... (SSPCA) and DCT based characterization of the spectral diffused reflectance images for wavelength selection and discrimination. These methods together with some other state-of-the-art statistical and mathematical analysis techniques are applied on datasets of different food items; meat, diaries, fruits...

  15. Multiple predictor smoothing methods for sensitivity analysis: Description of techniques

    International Nuclear Information System (INIS)

    Storlie, Curtis B.; Helton, Jon C.

    2008-01-01

    The use of multiple predictor smoothing methods in sampling-based sensitivity analyses of complex models is investigated. Specifically, sensitivity analysis procedures based on smoothing methods employing the stepwise application of the following nonparametric regression techniques are described: (i) locally weighted regression (LOESS), (ii) additive models, (iii) projection pursuit regression, and (iv) recursive partitioning regression. Then, in the second and concluding part of this presentation, the indicated procedures are illustrated with both simple test problems and results from a performance assessment for a radioactive waste disposal facility (i.e., the Waste Isolation Pilot Plant). As shown by the example illustrations, the use of smoothing procedures based on nonparametric regression techniques can yield more informative sensitivity analysis results than can be obtained with more traditional sensitivity analysis procedures based on linear regression, rank regression or quadratic regression when nonlinear relationships between model inputs and model predictions are present

  16. Sample preparation techniques of biological material for isotope analysis

    International Nuclear Information System (INIS)

    Axmann, H.; Sebastianelli, A.; Arrillaga, J.L.

    1990-01-01

    Sample preparation is an essential step in all isotope-aided experiments but often it is not given enough attention. The methods of sample preparation are very important to obtain reliable and precise analytical data and for further interpretation of results. The size of a sample required for chemical analysis is usually very small (10mg-1500mg). On the other hand the amount of harvested plant material from plots in a field experiment is often bulky (several kilograms) and the entire sample is too large for processing. In addition, while approaching maturity many crops show not only differences in physical consistency but also a non-uniformity in 15 N content among plant parts, requiring a plant fractionation or separation into parts (vegetative and reproductive) e.g. shoots and spikes, in case of small grain cereals, shoots and pods in case of grain legumes and tops and roots or beets (including crown) in case of sugar beet, etc. In any case the ultimate goal of these procedures is to obtain representative subsample harvested from greenhouse or field experiments for chemical analysis. Before harvesting an isotopic-aided experiment the method of sampling has to be selected. It should be based on the type of information required in relation to the objectives of the research and the availability of resources (staff, sample preparation equipment, analytical facilities, chemicals and supplies, etc.). 10 refs, 3 figs, 3 tabs

  17. DATA ANALYSIS TECHNIQUES IN SERVICE QUALITY LITERATURE: ESSENTIALS AND ADVANCES

    Directory of Open Access Journals (Sweden)

    Mohammed naved Khan

    2013-05-01

    Full Text Available Academic and business researchers have for long debated on the most appropriate data analysis techniques that can be employed in conducting empirical researches in the domain of services marketing. On the basis of an exhaustive review of literature, the present paper attempts to provide a concise and schematic portrayal of generally followed data analysis techniques in the field of services quality literature. Collectively, the extant literature suggests that there is a growing trend among researchers to rely on higher order multivariate techniques viz. confirmatory factor analysis, structural equation modeling etc. to generate and analyze complex models, while at times ignoring very basic and yet powerful procedures such as mean, t-Test, ANOVA and correlation. The marked shift in orientation of researchers towards using sophisticated analytical techniques can largely beattributed to the competition within the community of researchers in social sciences in general and those working in the area of service quality in particular as also growing demands of reviewers ofjournals. From a pragmatic viewpoint, it is expected that the paper will serve as a useful source of information and provide deeper insights to academic researchers, consultants, and practitionersinterested in modelling patterns of service quality and arriving at optimal solutions to increasingly complex management problems.

  18. Practical applications of activation analysis and other nuclear techniques

    International Nuclear Information System (INIS)

    Lyon, W.S.

    1982-01-01

    Neeutron activation analysis (NAA) is a versatile, sensitive multielement, usually nondestructive analytical technique used to determine elemental concentrations in a variety of materials. Samples are irradiated with neutrons in a nuclear reactor, removed, and for the nondestructive technique, the induced radioactivity measured. This measurement of γ rays emitted from specific radionuclides makes possible the quantitative determination of elements present. The method is described, advantages and disadvantages listed and a number of examples of its use given. Two other nuclear methods, particle induced x-ray emission and synchrotron produced x-ray fluorescence are also briefly discussed

  19. Maximum entropy technique in the doublet structure analysis

    International Nuclear Information System (INIS)

    Belashev, B.Z.; Panebrattsev, Yu.A.; Shakhaliev, Eh.I.; Soroko, L.M.

    1998-01-01

    The Maximum Entropy Technique (MENT) for solution of the inverse problems is explained. The effective computer program for resolution of the nonlinear equations system encountered in the MENT has been developed and tested. The possibilities of the MENT have been demonstrated on the example of the MENT in the doublet structure analysis of noisy experimental data. The comparison of the MENT results with results of the Fourier algorithm technique without regularization is presented. The tolerant noise level is equal to 30% for MENT and only 0.1% for the Fourier algorithm

  20. Multi-element analysis of lubricant oil by WDXRF technique using thin-film sample preparation

    International Nuclear Information System (INIS)

    Scapin, M. A.; Salvador, V. L. R.; Lopes, C. D.; Sato, I. M.

    2006-01-01

    The quantitative analysis of the chemical elements in matrices like oils or gels represents a challenge for the analytical chemists. The classics methods or instrumental techniques such as atomic absorption spectrometry (AAS) and plasma optical emission spectrometry (ICP-OES) need chemical treatments, mainly sample dissolution and degradation processes. X-ray fluorescence technique allows a direct and multi-element analysis without previous sample treatments. In this work, a sensible method for the determination of elements Mg, Al, Si, P, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Mo, Ag, Sn, Ba and Pb in lubricating oil is presented. The x-ray fluorescence (WDXRF) technique using linear regression method and thin film sample preparation was used. The validation of the methodology (repeatability and accuracy) was obtained by the analysis of the standard reference materials SRM Alpha AESAR lot 703527D, applying the Chauvenet, Cochrane, ANOVA and Z-score statistical tests. The method presents a relative standard deviation lower than 10% for all the elements, except for Pb determination (RSD Pb 15%). The Z-score values for all the elements were in the range -2 < Z < 2, indicating a very good accuracy.(Full text)

  1. A physico-chemical characterisation technique for determining the pore-water chemistry in argillaceous rocks

    International Nuclear Information System (INIS)

    Baeyens, B.; Bradbury, M.H.

    1991-09-01

    A prerequisite for carrying out credible sorption studies is the definition of an aqueous phase composition which is in equilibrium with the solid phase. Experimental methods and data analysis procedures are described which enable an equilibrium water composition to be produced for argillaceous rocks which is not dependent on liquid to solid (L:S) ratios. Since a Valanginian marl formation is under consideration by Nagra as a potential rock for the disposal of low and short-lived medium level radioactive waste in Switzerland, samples of this material were chosen for this investigation. Aqueous phase and nickel ethylenediamine extraction experiments were carried out at different L:S ratios under controlled atmosphere conditions (P CO 2 =10 -2 bar, O 2 ≤ 5 ppm ). The results from these tests and petrographical examinations were combined to define the system in terms of the physico-chemical characteristics of the clay mineral component (CEC and cation occupancies) and the identities of highly soluble and solubility limited phases in the marl. The geochemical code PHREEQE was used in conjunction with the Gapon equations to calculate the pore water composition. This work clearly showed that pore water chemistries obtained from aqueous extracts alone may lead to an arbitrary water chemistry in argillaceous rock systems, particularly with respect to ionic composition and ionic strength, which may have important consequences for radionuclide speciation and sorption studies. (author) 11 figs., 12 tabs., 25 refs

  2. Equatorial F region neutral winds and shears near sunset measured with chemical release techniques

    Science.gov (United States)

    Kiene, A.; Larsen, M. F.; Kudeki, E.

    2015-10-01

    The period near sunset is a dynamic and critical time for the daily development of the equatorial nighttime ionosphere and the instabilities that occur there. It is during these hours that the preconditions necessary for the later development of Equatorial Spread F (ESF) plasma instabilities occur. The neutral dynamics of the sunset ionosphere are also of critical importance to the generation of currents and electric fields; however, the behavior of the neutrals is experimentally understood primarily through very limited single-altitude measurements or measurements that provide weighted altitude means of the winds as a function of time. To date, there have been very few vertically resolved neutral wind measurements in the F region at sunset. We present two sets of sounding rocket chemical release measurements, one from a launch in the Marshall Islands on Kwajalein atoll and one from Alcantara, Brazil. Analysis of the release motions has yielded vertically resolved neutral wind profiles that show both the mean horizontal winds and the vertical shears in the winds. In both experiments, we observe significant vertical gradients in the zonal wind that are unexpected by classical assumptions about the behavior of the neutral wind at these altitudes at sunset near the geomagnetic equator.

  3. Chemical Abundance Analysis of Moving Group W11450 (Latham 1)

    Science.gov (United States)

    O'Connell, Julia E.; Martens, Kylee; Frinchaboy, Peter M.

    2016-12-01

    We present elemental abundances for all seven stars in Moving Group W11450 (Latham 1) to determine if they may be chemically related. These stars appear to be both spatially and kinematically related, but no spectroscopic abundance analysis exists in literature. Abundances for eight elements were derived via equivalent width analyses of high-resolution (R ˜ 60,000), high-signal-to-noise ratio ( ˜ 100) spectra obtained with the Otto Struve 2.1 m telescope and the Sandiford Echelle Spectrograph at McDonald Observatory. The large star-to-star scatter in metallicity, -0.55 ≤ [Fe/H] ≤slant 0.06 dex (σ = 0.25), implies these stars were not produced from the same chemically homogeneous molecular cloud, and are therefore not part of a remnant or open cluster as previously proposed. Prior to this analysis, it was suggested that two stars in the group, W11449 and W11450, are possible wide binaries. The candidate wide binary pair show similar chemical abundance patterns with not only iron but with other elements analyzed in this study, suggesting the proposed connection between these two stars may be real.

  4. Nuclear techniques of analysis in diamond synthesis and annealing

    Energy Technology Data Exchange (ETDEWEB)

    Jamieson, D. N.; Prawer, S.; Gonon, P.; Walker, R.; Dooley, S.; Bettiol, A.; Pearce, J. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    Nuclear techniques of analysis have played an important role in the study of synthetic and laser annealed diamond. These measurements have mainly used ion beam analysis with a focused MeV ion beam in a nuclear microprobe system. A variety of techniques have been employed. One of the most important is nuclear elastic scattering, sometimes called non-Rutherford scattering, which has been used to accurately characterise diamond films for thickness and composition. This is possible by the use of a database of measured scattering cross sections. Recently, this work has been extended and nuclear elastic scattering cross sections for both natural boron isotopes have been measured. For radiation damaged diamond, a focused laser annealing scheme has been developed which produces near complete regrowth of MeV phosphorus implanted diamonds. In the laser annealed regions, proton induced x-ray emission has been used to show that 50 % of the P atoms occupy lattice sites. This opens the way to produce n-type diamond for microelectronic device applications. All these analytical applications utilize a focused MeV microbeam which is ideally suited for diamond analysis. This presentation reviews these applications, as well as the technology of nuclear techniques of analysis for diamond with a focused beam. 9 refs., 6 figs.

  5. Reliability analysis of large scaled structures by optimization technique

    International Nuclear Information System (INIS)

    Ishikawa, N.; Mihara, T.; Iizuka, M.

    1987-01-01

    This paper presents a reliability analysis based on the optimization technique using PNET (Probabilistic Network Evaluation Technique) method for the highly redundant structures having a large number of collapse modes. This approach makes the best use of the merit of the optimization technique in which the idea of PNET method is used. The analytical process involves the minimization of safety index of the representative mode, subjected to satisfaction of the mechanism condition and of the positive external work. The procedure entails the sequential performance of a series of the NLP (Nonlinear Programming) problems, where the correlation condition as the idea of PNET method pertaining to the representative mode is taken as an additional constraint to the next analysis. Upon succeeding iterations, the final analysis is achieved when a collapse probability at the subsequent mode is extremely less than the value at the 1st mode. The approximate collapse probability of the structure is defined as the sum of the collapse probabilities of the representative modes classified by the extent of correlation. Then, in order to confirm the validity of the proposed method, the conventional Monte Carlo simulation is also revised by using the collapse load analysis. Finally, two fairly large structures were analyzed to illustrate the scope and application of the approach. (orig./HP)

  6. Nuclear techniques of analysis in diamond synthesis and annealing

    Energy Technology Data Exchange (ETDEWEB)

    Jamieson, D N; Prawer, S; Gonon, P; Walker, R; Dooley, S; Bettiol, A; Pearce, J [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1997-12-31

    Nuclear techniques of analysis have played an important role in the study of synthetic and laser annealed diamond. These measurements have mainly used ion beam analysis with a focused MeV ion beam in a nuclear microprobe system. A variety of techniques have been employed. One of the most important is nuclear elastic scattering, sometimes called non-Rutherford scattering, which has been used to accurately characterise diamond films for thickness and composition. This is possible by the use of a database of measured scattering cross sections. Recently, this work has been extended and nuclear elastic scattering cross sections for both natural boron isotopes have been measured. For radiation damaged diamond, a focused laser annealing scheme has been developed which produces near complete regrowth of MeV phosphorus implanted diamonds. In the laser annealed regions, proton induced x-ray emission has been used to show that 50 % of the P atoms occupy lattice sites. This opens the way to produce n-type diamond for microelectronic device applications. All these analytical applications utilize a focused MeV microbeam which is ideally suited for diamond analysis. This presentation reviews these applications, as well as the technology of nuclear techniques of analysis for diamond with a focused beam. 9 refs., 6 figs.

  7. Development of fault diagnostic technique using reactor noise analysis

    International Nuclear Information System (INIS)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B.

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  8. Noble Gas Measurement and Analysis Technique for Monitoring Reprocessing Facilities

    International Nuclear Information System (INIS)

    William S. Charlton

    1999-01-01

    An environmental monitoring technique using analysis of stable noble gas isotopic ratios on-stack at a reprocessing facility was developed. This technique integrates existing technologies to strengthen safeguards at reprocessing facilities. The isotopic ratios are measured using a mass spectrometry system and are compared to a database of calculated isotopic ratios using a Bayesian data analysis method to determine specific fuel parameters (e.g., burnup, fuel type, fuel age, etc.). These inferred parameters can be used by investigators to verify operator declarations. A user-friendly software application (named NOVA) was developed for the application of this technique. NOVA included a Visual Basic user interface coupling a Bayesian data analysis procedure to a reactor physics database (calculated using the Monteburns 3.01 code system). The integrated system (mass spectrometry, reactor modeling, and data analysis) was validated using on-stack measurements during the reprocessing of target fuel from a U.S. production reactor and gas samples from the processing of EBR-II fast breeder reactor driver fuel. These measurements led to an inferred burnup that matched the declared burnup with sufficient accuracy and consistency for most safeguards applications. The NOVA code was also tested using numerous light water reactor measurements from the literature. NOVA was capable of accurately determining spent fuel type, burnup, and fuel age for these experimental results. Work should continue to demonstrate the robustness of this system for production, power, and research reactor fuels

  9. Nuclear techniques of analysis in diamond synthesis and annealing

    International Nuclear Information System (INIS)

    Jamieson, D. N.; Prawer, S.; Gonon, P.; Walker, R.; Dooley, S.; Bettiol, A.; Pearce, J.

    1996-01-01

    Nuclear techniques of analysis have played an important role in the study of synthetic and laser annealed diamond. These measurements have mainly used ion beam analysis with a focused MeV ion beam in a nuclear microprobe system. A variety of techniques have been employed. One of the most important is nuclear elastic scattering, sometimes called non-Rutherford scattering, which has been used to accurately characterise diamond films for thickness and composition. This is possible by the use of a database of measured scattering cross sections. Recently, this work has been extended and nuclear elastic scattering cross sections for both natural boron isotopes have been measured. For radiation damaged diamond, a focused laser annealing scheme has been developed which produces near complete regrowth of MeV phosphorus implanted diamonds. In the laser annealed regions, proton induced x-ray emission has been used to show that 50 % of the P atoms occupy lattice sites. This opens the way to produce n-type diamond for microelectronic device applications. All these analytical applications utilize a focused MeV microbeam which is ideally suited for diamond analysis. This presentation reviews these applications, as well as the technology of nuclear techniques of analysis for diamond with a focused beam. 9 refs., 6 figs

  10. Development of fault diagnostic technique using reactor noise analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  11. The 11th Australian Conference on Nuclear Techniques of Analysis and the 5th Vacuum Society of Australia Congress. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    This publication contains summaries submitted by the participants at the joint AINSE Conference on Nuclear Techniques of Analysis and the Vacuum Society of Australia Congress. Topics covered include: ion beam analysis and its applications; structural chemical analysis of various materials and thin films, environmental studies, accelerator mass spectrometry, ion implantation. The programme of the meeting and list of participants are also included in this volume. Each of the presentations was separately indexed.

  12. The 11th Australian Conference on Nuclear Techniques of Analysis and the 5th Vacuum Society of Australia Congress. Proceedings

    International Nuclear Information System (INIS)

    1999-01-01

    This publication contains summaries submitted by the participants at the joint AINSE Conference on Nuclear Techniques of Analysis and the Vacuum Society of Australia Congress. Topics covered include: ion beam analysis and its applications; structural chemical analysis of various materials and thin films, environmental studies, accelerator mass spectrometry, ion implantation. The programme of the meeting and list of participants are also included in this volume. Each of the presentations was separately indexed

  13. Quantitative analysis of abused drugs in physiological fluids by gas chromatography/chemical ionization mass spectrometry

    International Nuclear Information System (INIS)

    Foltz, R.L.

    1978-01-01

    Methods have been developed for quantitative analysis of commonly abused drugs in physiological fluids using gas chromatography/chemical ionization mass spectrometry. The methods are being evaluated in volunteer analytical and toxicological laboratories, and analytical manuals describing the methods are being prepared. The specific drug and metabolites included in this program are: Δ 9 -tetrahydrocannabinol, methadone, phencyclidine, methaqualone, morphine, amphetamine, methamphetamine, mescaline, 2,5-dimethoxy-4-methyl amphetamine, cocaine, benzoylecgonine, diazepam, and N-desmethyldiazepam. The current analytical methods utilize relatively conventional instrumentation and procedures, and are capable of measuring drug concentrations as low as 1 ng/ml. Various newer techniques such as sample clean-up by high performance liquid chromatography, separation by glass capillary chromatography, and ionization by negative ion chemical ionization are being investigated with respect to their potential for achieving higher sensitivity and specificity, as well as their ability to facilitate simultaneous analysis of more than one drug and metabolite. (Auth.)

  14. Development of a new technique of localised analysis of electrically active defects in semiconductors

    International Nuclear Information System (INIS)

    Heiser, T.

    1988-07-01

    An analysis technique derived from minority carrier transient spectroscopy (MCTS) was developed. By giving this technique spatial resolution via a focused optical beam, it is possible to exploit the high sensitivity and the spectroscopic nature of the technique to develop a method called scanning MCTS (SMCTS) which can be used to acquire information on lateral distribution of electrically active flaws in semiconductors or associated chemical impurities. The optimum conditions, corresponding to the maximum signal for the highest resolution, can be expressed by the value of a signal parameter. The transients system was digitized, considerably reducing background noise. In order to link the SMCTS to a given flaw, two methods for exploiting the transients are used. The method was verified in tests with artificial defects created by laser and on real cases, arising in industrial processes [fr

  15. New trends in sample preparation techniques for environmental analysis.

    Science.gov (United States)

    Ribeiro, Cláudia; Ribeiro, Ana Rita; Maia, Alexandra S; Gonçalves, Virgínia M F; Tiritan, Maria Elizabeth

    2014-01-01

    Environmental samples include a wide variety of complex matrices, with low concentrations of analytes and presence of several interferences. Sample preparation is a critical step and the main source of uncertainties in the analysis of environmental samples, and it is usually laborious, high cost, time consuming, and polluting. In this context, there is increasing interest in developing faster, cost-effective, and environmentally friendly sample preparation techniques. Recently, new methods have been developed and optimized in order to miniaturize extraction steps, to reduce solvent consumption or become solventless, and to automate systems. This review attempts to present an overview of the fundamentals, procedure, and application of the most recently developed sample preparation techniques for the extraction, cleanup, and concentration of organic pollutants from environmental samples. These techniques include: solid phase microextraction, on-line solid phase extraction, microextraction by packed sorbent, dispersive liquid-liquid microextraction, and QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe).

  16. Model order reduction techniques with applications in finite element analysis

    CERN Document Server

    Qu, Zu-Qing

    2004-01-01

    Despite the continued rapid advance in computing speed and memory the increase in the complexity of models used by engineers persists in outpacing them. Even where there is access to the latest hardware, simulations are often extremely computationally intensive and time-consuming when full-blown models are under consideration. The need to reduce the computational cost involved when dealing with high-order/many-degree-of-freedom models can be offset by adroit computation. In this light, model-reduction methods have become a major goal of simulation and modeling research. Model reduction can also ameliorate problems in the correlation of widely used finite-element analyses and test analysis models produced by excessive system complexity. Model Order Reduction Techniques explains and compares such methods focusing mainly on recent work in dynamic condensation techniques: - Compares the effectiveness of static, exact, dynamic, SEREP and iterative-dynamic condensation techniques in producing valid reduced-order mo...

  17. Novel technique for coal pyrolysis and hydrogenation production analysis

    Energy Technology Data Exchange (ETDEWEB)

    Pfefferle, L.D.

    1990-01-01

    The overall objective of this study is to establish vacuum ultraviolet photoionization-MS and VUV pulsed EI-MS as useful tools for a simpler and more accurate direct mass spectrometric measurement of a broad range of hydrocarbon compounds in complex mixtures for ultimate application to the study of the kinetics of coal hydrogenation and pyrolysis processes. The VUV-MS technique allows ionization of a broad range of species with minimal fragmentation. Many compounds of interest can be detected with the 118 nm wavelength, but additional compound selectivity is achievable by tuning the wavelength of the photo-ionization source in the VUV. Resonant four wave mixing techniques in Hg vapor will allow near continuous tuning from about 126 to 106 nm. This technique would facilitate the scientific investigation of coal upgrading processes such as pyrolysis and hydrogenation by allowing accurate direct analysis of both stable and intermediate reaction products.

  18. QSAR modeling and chemical space analysis of antimalarial compounds

    Science.gov (United States)

    Sidorov, Pavel; Viira, Birgit; Davioud-Charvet, Elisabeth; Maran, Uko; Marcou, Gilles; Horvath, Dragos; Varnek, Alexandre

    2017-05-01

    Generative topographic mapping (GTM) has been used to visualize and analyze the chemical space of antimalarial compounds as well as to build predictive models linking structure of molecules with their antimalarial activity. For this, a database, including 3000 molecules tested in one or several of 17 anti- Plasmodium activity assessment protocols, has been compiled by assembling experimental data from in-house and ChEMBL databases. GTM classification models built on subsets corresponding to individual bioassays perform similarly to the earlier reported SVM models. Zones preferentially populated by active and inactive molecules, respectively, clearly emerge in the class landscapes supported by the GTM model. Their analysis resulted in identification of privileged structural motifs of potential antimalarial compounds. Projection of marketed antimalarial drugs on this map allowed us to delineate several areas in the chemical space corresponding to different mechanisms of antimalarial activity. This helped us to make a suggestion about the mode of action of the molecules populating these zones.

  19. Method for fractional solid-waste sampling and chemical analysis

    DEFF Research Database (Denmark)

    Riber, Christian; Rodushkin, I.; Spliid, Henrik

    2007-01-01

    four subsampling methods and five digestion methods, paying attention to the heterogeneity and the material characteristics of the waste fractions, it was possible to determine 61 substances with low detection limits, reasonable variance, and high accuracy. For most of the substances of environmental...... of variance (20-85% of the overall variation). Only by increasing the sample size significantly can this variance be reduced. The accuracy and short-term reproducibility of the chemical characterization were good, as determined by the analysis of several relevant certified reference materials. Typically, six...... to eight different certified reference materials representing a range of concentrations levels and matrix characteristics were included. Based on the documentation provided, the methods introduced were considered satisfactory for characterization of the chemical composition of waste-material fractions...

  20. Sample handling and chemical procedures for efficacious trace analysis of urine by neutron activation analysis

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Rack, E.P.; Roman, F.R.

    1988-01-01

    Important for the determination of trace elements, ions, or compounds in urine by chemical neutron activation analysis is the optimization of sample handling, preirradiation chemistry, and radioassay procedures necessary for viable analysis. Each element, because of its natural abundance in the earth's crust and, hence, its potential for reagent and environmental contamination, requires specific procedures for storage, handling, and preirradiation chemistry. Radioassay techniques for radionuclides vary depending on their half-lives and decay characteristics. Described in this paper are optimized procedures for aluminum and selenium. While 28 Al (T 1/2 = 2.24 min) and 77m Se(T 1/2 = 17.4s) have short half-lives, their gamma-ray spectra are quite different. Aluminum-28 decays by a 1779-keV gamma and 77m Se by a 162-keV gamma. Unlike selenium, aluminum is a ubiquitous element in the environment requiring special handling to minimize contamination in all phases of its analytical determination

  1. Optical and electrical properties of ZrSe3 single crystals grown by chemical vapour transport technique

    International Nuclear Information System (INIS)

    Patel, Kaushik; Prajapati, Jagdish; Vaidya, Rajiv; Patel, S.G.

    2005-01-01

    Single crystals of the lamellar compound, ZrSe 3 , were grown by chemical vapour transport technique using iodine as a transporting agent. The grown crystals were characterized with the help of energy dispersive analysis by X-ray (EDAX), which gave confirmation about the stoichiometry. The optical band gap measurement of as grown crystals was carried out with the help of optical absorption spectra in the range 700-1450 nm. The indirect as well as direct band gap of ZrSe 3 were found to be 1.1 eV and 1.47 eV, respectively. The resistivity of the as grown crystals was measured using van der Pauw method. The Hall parameters of the grown crystals were determined at room temperature from Hall effect measurements. Electrical resistivity measurements were performed on this crystal in the temperature range 303-423 K. The crystals were found to exhibit semiconducting nature in this range. The activation energy and anisotropy measurements were carried out for this crystal. Pressure dependence of electrical resistance was studied using Bridgman opposed anvils set up up to 8 GPa. The semiconducting nature of ZrSe 3 single crystal was inferred from the graph of resistance vs pressure. The results obtained are discussed in detail. (author)

  2. Small area analysis using micro-diffraction techniques

    International Nuclear Information System (INIS)

    Goehner, Raymond P.; Tissot, Ralph G. Jr.; Michael, Joseph R.

    2000-01-01

    An overall trend toward smaller electronic packages and devices makes it increasingly important and difficult to obtain meaningful diffraction information from small areas. X-ray micro-diffraction, electron back-scattered diffraction (EBSD) and Kossel are micro-diffraction techniques used for crystallographic analysis including texture, phase identification and strain measurements. X-ray micro-diffraction primarily is used for phase analysis and residual strain measurements. X-ray micro-diffraction primarily is used for phase analysis and residual strain measurements of areas between 10 microm to 100 microm. For areas this small glass capillary optics are used for producing a usable collimated x-ray beam. These optics are designed to reflect x-rays below the critical angle therefore allowing for larger solid acceptance angle at the x-ray source resulting in brighter smaller x-ray beams. The determination of residual strain using micro-diffraction techniques is very important to the semiconductor industry. Residual stresses have caused voiding of the interconnect metal which then destroys electrical continuity. Being able to determine the residual stress helps industry to predict failures from the aging effects of interconnects due to this stress voiding. Stress measurements would be impossible using a conventional x-ray diffractometer; however, utilizing a 30 microm glass capillary these small areas are readily assessable for analysis. Kossel produces a wide angle diffraction pattern from fluorescent x-rays generated in the sample by an e-beam in a SEM. This technique can yield very precise lattice parameters for determining strain. Fig. 2 shows a Kossel pattern from a Ni specimen. Phase analysis on small areas is also possible using an energy dispersive spectrometer (EBSD) and x-ray micro-diffraction techniques. EBSD has the advantage of allowing the user to observe the area of interest using the excellent imaging capabilities of the SEM. An EDS detector has been

  3. A Comparative Analysis of Uranium Ore using Laser Fluorimetric and gamma Spectrometry Techniques

    International Nuclear Information System (INIS)

    Madbouly, M.; Nassef, M. H.; El-Mongy, S.A.; Diab, A.M.

    2009-01-01

    A developed chemical separation method was used for the analysis of uranium in a standard U-ore (IAEA-RGU-1) by LASER fluorimetric technique. The non-destructive gamma assay technique was also applied to verify and compare the uranium content analyzed using laser technique. The results of the uranium analysis obtained by laser fluorimetry were found to be in the range of 360 - 420 μg/g with an average value of 390 μg/g. The bias between the measured and the certified value does not exceed 9.9%. For gamma-ray spectrometric analysis, the results of the measured uranium content were found to be in the range of 393.8 - 399.4 μg/g with an average value of 396.3 μg/g. The % difference in the case of γ- assay was 1.6 %. In general, the methods of analysis used in this study are applicable for a precise determination of uranium. It can be concluded that, laser analysis is preferred for assay of uranium ore due to the required small sample weight, the low time of sample preparation and cost of analysis.

  4. Trace elements in California aerosols. Part I. Instrumental neutron activation analysis techniques

    International Nuclear Information System (INIS)

    Ragaini, R.C.; Ralston, H.R.; Garvis, D.; Kaifer, R.

    1975-01-01

    Instrumental Neutron Activation Analysis (INAA) done at LLL played a key role in the 1972--1974 California Aerosol Characterization Experiment (ACHEX), a major experiment in the chemistry of aerosols in urban and non-urban sites of California sponsored by the State of California Air Resources Board. The main purpose of INAA was to measure the particle size distributions and diurnal patterns of key chemical constituents in aerosols collected in California. These data were used to satisfy some of the key objectives of ACHEX, including aerosol characterization and evaluation of the origins and evolutions of aerosols. Secondary uses of INAA were the validations of the Lundgren rotating drum cascade impactors used in the ACHEX, and validations of other analytical techniques used in the chemical analyses. As a result of these studies, it was concluded that techniques using INAA were useful operational methods for chemical analysis of aerosols collected over two-hour periods in urban air with an active monitoring program. (U.S.)

  5. Nanolithography and nanochemistry: probe-related patterning techniques and chemical modification for nanometer-sized devices

    NARCIS (Netherlands)

    Wouters, D.; Schubert, U.S.

    2004-01-01

    The size regime for devices produced by photolithographic techniques is limited. Therefore, other patterning techniques have been intensively studied to create smaller structures. Scanning-probe-based patterning techniques, such as dip-pen lithography, local force-induced patterning, and local-probe

  6. Metabolic Engineering: Techniques for analysis of targets for genetic manipulations

    DEFF Research Database (Denmark)

    Nielsen, Jens Bredal

    1998-01-01

    Metabolic engineering has been defined as the purposeful modification of intermediary metabolism using recombinant DNA techniques. With this definition metabolic engineering includes: (1) inserting new pathways in microorganisms with the aim of producing novel metabolites, e.g., production...... of polyketides by Streptomyces; (2) production of heterologous peptides, e.g., production of human insulin, erythropoitin, and tPA; and (3) improvement of both new and existing processes, e.g., production of antibiotics and industrial enzymes. Metabolic engineering is a multidisciplinary approach, which involves...... input from chemical engineers, molecular biologists, biochemists, physiologists, and analytical chemists. Obviously, molecular biology is central in the production of novel products, as well as in the improvement of existing processes. However, in the latter case, input from other disciplines is pivotal...

  7. Modular techniques for dynamic fault-tree analysis

    Science.gov (United States)

    Patterson-Hine, F. A.; Dugan, Joanne B.

    1992-01-01

    It is noted that current approaches used to assess the dependability of complex systems such as Space Station Freedom and the Air Traffic Control System are incapable of handling the size and complexity of these highly integrated designs. A novel technique for modeling such systems which is built upon current techniques in Markov theory and combinatorial analysis is described. It enables the development of a hierarchical representation of system behavior which is more flexible than either technique alone. A solution strategy which is based on an object-oriented approach to model representation and evaluation is discussed. The technique is virtually transparent to the user since the fault tree models can be built graphically and the objects defined automatically. The tree modularization procedure allows the two model types, Markov and combinatoric, to coexist and does not require that the entire fault tree be translated to a Markov chain for evaluation. This effectively reduces the size of the Markov chain required and enables solutions with less truncation, making analysis of longer mission times possible. Using the fault-tolerant parallel processor as an example, a model is built and solved for a specific mission scenario and the solution approach is illustrated in detail.

  8. Recent development in mass spectrometry and its hyphenated techniques for the analysis of medicinal plants.

    Science.gov (United States)

    Zhu, Ming-Zhi; Chen, Gui-Lin; Wu, Jian-Lin; Li, Na; Liu, Zhong-Hua; Guo, Ming-Quan

    2018-04-23

    Medicinal plants are gaining increasing attention worldwide due to their empirical therapeutic efficacy and being a huge natural compound pool for new drug discovery and development. The efficacy, safety and quality of medicinal plants are the main concerns, which are highly dependent on the comprehensive analysis of chemical components in the medicinal plants. With the advances in mass spectrometry (MS) techniques, comprehensive analysis and fast identification of complex phytochemical components have become feasible, and may meet the needs, for the analysis of medicinal plants. Our aim is to provide an overview on the latest developments in MS and its hyphenated technique and their applications for the comprehensive analysis of medicinal plants. Application of various MS and its hyphenated techniques for the analysis of medicinal plants, including but not limited to one-dimensional chromatography, multiple-dimensional chromatography coupled to MS, ambient ionisation MS, and mass spectral database, have been reviewed and compared in this work. Recent advancs in MS and its hyphenated techniques have made MS one of the most powerful tools for the analysis of complex extracts from medicinal plants due to its excellent separation and identification ability, high sensitivity and resolution, and wide detection dynamic range. To achieve high-throughput or multi-dimensional analysis of medicinal plants, the state-of-the-art MS and its hyphenated techniques have played, and will continue to play a great role in being the major platform for their further research in order to obtain insight into both their empirical therapeutic efficacy and quality control. Copyright © 2018 John Wiley & Sons, Ltd.

  9. A review of residual stress analysis using thermoelastic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, A F; Dulieu-Barton, J M; Quinn, S [University of Southampton, School of Engineering Sciences, Highfield, Southampton, SO17 1BJ (United Kingdom); Burguete, R L [Airbus UK Ltd., New Filton House, Filton, Bristol, BS99 7AR (United Kingdom)

    2009-08-01

    Thermoelastic Stress Analysis (TSA) is a full-field technique for experimental stress analysis that is based on infra-red thermography. The technique has proved to be extremely effective for studying elastic stress fields and is now well established. It is based on the measurement of the temperature change that occurs as a result of a stress change. As residual stress is essentially a mean stress it is accepted that the linear form of the TSA relationship cannot be used to evaluate residual stresses. However, there are situations where this linear relationship is not valid or departures in material properties due to manufacturing procedures have enabled evaluations of residual stresses. The purpose of this paper is to review the current status of using a TSA based approach for the evaluation of residual stresses and to provide some examples of where promising results have been obtained.

  10. A review of residual stress analysis using thermoelastic techniques

    International Nuclear Information System (INIS)

    Robinson, A F; Dulieu-Barton, J M; Quinn, S; Burguete, R L

    2009-01-01

    Thermoelastic Stress Analysis (TSA) is a full-field technique for experimental stress analysis that is based on infra-red thermography. The technique has proved to be extremely effective for studying elastic stress fields and is now well established. It is based on the measurement of the temperature change that occurs as a result of a stress change. As residual stress is essentially a mean stress it is accepted that the linear form of the TSA relationship cannot be used to evaluate residual stresses. However, there are situations where this linear relationship is not valid or departures in material properties due to manufacturing procedures have enabled evaluations of residual stresses. The purpose of this paper is to review the current status of using a TSA based approach for the evaluation of residual stresses and to provide some examples of where promising results have been obtained.

  11. Technique Triangulation for Validation in Directed Content Analysis

    Directory of Open Access Journals (Sweden)

    Áine M. Humble PhD

    2009-09-01

    Full Text Available Division of labor in wedding planning varies for first-time marriages, with three types of couples—traditional, transitional, and egalitarian—identified, but nothing is known about wedding planning for remarrying individuals. Using semistructured interviews, the author interviewed 14 couples in which at least one person had remarried and used directed content analysis to investigate the extent to which the aforementioned typology could be transferred to this different context. In this paper she describes how a triangulation of analytic techniques provided validation for couple classifications and also helped with moving beyond “blind spots” in data analysis. Analytic approaches were the constant comparative technique, rank order comparison, and visual representation of coding, using MAXQDA 2007's tool called TextPortraits.

  12. A BWR 24-month cycle analysis using multicycle techniques

    International Nuclear Information System (INIS)

    Hartley, K.D.

    1993-01-01

    Boiling water reactor (BWR) fuel cycle design analyses have become increasingly challenging in the past several years. As utilities continue to seek improved capacity factors, reduced power generation costs, and reduced outage costs, longer cycle lengths and fuel design optimization become important considerations. Accurate multicycle analysis techniques are necessary to determine the viability of fuel designs and cycle operating strategies to meet reactor operating requirements, e.g., meet thermal and reactivity margin constraints, while minimizing overall fuel cycle costs. Siemens Power Corporation (SPC), Nuclear Division, has successfully employed multi-cycle analysis techniques with realistic rodded cycle depletions to demonstrate equilibrium fuel cycle performance in 24-month cycles. Analyses have been performed by a BWR/5 reactor, at both rated and uprated power conditions

  13. Chemical and sequential analysis of some metals in sediments from the North Coast of the Gulf of Mexico

    International Nuclear Information System (INIS)

    Trinidad Martinez; Brenda Estanol; Miguel Angel Zuniga

    2016-01-01

    Sediments collected from the North Coast of the Gulf of Mexico got carefully mixed, dried, and finally subjected to physical and chemical analysis. Metal concentration was determined by energy dispersive X-ray fluorescence (EDXRF). Sequential chemical analysis was performed by modified TESSIER technique. Results and statistical analysis (α = 0.05) show concentrations of most elements (excepting Mn, Ca, Ga, As and Pb) in the range of those of the earth crust's values, which set a sampling zone base line. Sequential extraction shows the potential risk of mobilization of metals sequestered in particulate phases by oxidation of anoxic sediments or intense organic matter degradation. (author)

  14. Ion beam analysis techniques applied to large scale pollution studies

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, D D; Bailey, G; Martin, J; Garton, D; Noorman, H; Stelcer, E; Johnson, P [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1994-12-31

    Ion Beam Analysis (IBA) techniques are ideally suited to analyse the thousands of filter papers a year that may originate from a large scale aerosol sampling network. They are fast multi-elemental and, for the most part, non-destructive so other analytical methods such as neutron activation and ion chromatography can be performed afterwards. ANSTO in collaboration with the NSW EPA, Pacific Power and the Universities of NSW and Macquarie has established a large area fine aerosol sampling network covering nearly 80,000 square kilometres of NSW with 25 fine particle samplers. This network known as ASP was funded by the Energy Research and Development Corporation (ERDC) and commenced sampling on 1 July 1991. The cyclone sampler at each site has a 2.5 {mu}m particle diameter cut off and runs for 24 hours every Sunday and Wednesday using one Gillman 25mm diameter stretched Teflon filter for each day. These filters are ideal targets for ion beam analysis work. Currently ANSTO receives 300 filters per month from this network for analysis using its accelerator based ion beam techniques on the 3 MV Van de Graaff accelerator. One week a month of accelerator time is dedicated to this analysis. Four simultaneous accelerator based IBA techniques are used at ANSTO, to analyse for the following 24 elements: H, C, N, O, F, Na, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Cu, Ni, Co, Zn, Br and Pb. The IBA techniques were proved invaluable in identifying sources of fine particles and their spatial and seasonal variations accross the large area sampled by the ASP network. 3 figs.

  15. Ion beam analysis techniques applied to large scale pollution studies

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, D.D.; Bailey, G.; Martin, J.; Garton, D.; Noorman, H.; Stelcer, E.; Johnson, P. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1993-12-31

    Ion Beam Analysis (IBA) techniques are ideally suited to analyse the thousands of filter papers a year that may originate from a large scale aerosol sampling network. They are fast multi-elemental and, for the most part, non-destructive so other analytical methods such as neutron activation and ion chromatography can be performed afterwards. ANSTO in collaboration with the NSW EPA, Pacific Power and the Universities of NSW and Macquarie has established a large area fine aerosol sampling network covering nearly 80,000 square kilometres of NSW with 25 fine particle samplers. This network known as ASP was funded by the Energy Research and Development Corporation (ERDC) and commenced sampling on 1 July 1991. The cyclone sampler at each site has a 2.5 {mu}m particle diameter cut off and runs for 24 hours every Sunday and Wednesday using one Gillman 25mm diameter stretched Teflon filter for each day. These filters are ideal targets for ion beam analysis work. Currently ANSTO receives 300 filters per month from this network for analysis using its accelerator based ion beam techniques on the 3 MV Van de Graaff accelerator. One week a month of accelerator time is dedicated to this analysis. Four simultaneous accelerator based IBA techniques are used at ANSTO, to analyse for the following 24 elements: H, C, N, O, F, Na, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Cu, Ni, Co, Zn, Br and Pb. The IBA techniques were proved invaluable in identifying sources of fine particles and their spatial and seasonal variations accross the large area sampled by the ASP network. 3 figs.

  16. Analysis of Cell Phone Usage Using Correlation Techniques

    OpenAIRE

    T S R MURTHY; D. SIVA RAMA KRISHNA

    2011-01-01

    The present paper is a sample survey analysis, examined based on correlation techniques. The usage ofmobile phones is clearly almost un-avoidable these days and as such the authors have made a systematicsurvey through a well prepared questionnaire on making use of mobile phones to the maximum extent.These samples are various economical groups across a population of over one-lakh people. The resultsare scientifically categorized and interpreted to match the ground reality.

  17. Analysis of corrosion-product transport using nondestructive XRF and MS techniques

    International Nuclear Information System (INIS)

    Sawicka, B.D.; Sawicki, J.A.

    1998-01-01

    This paper describes the application of X-ray fluorescence (XRF) and Moessbauer spectroscopy (MS) techniques to monitor corrosion-product transport (CPT) in water circuits of nuclear reactors. The combination of XRF and MS techniques was applied in studies of CPT crud filters from both primary- and secondary-side water circuits (i.e., radioactive and nonradioactive specimens) of CANDU reactors. The XRF-MS method allows nondestructive analysis of species collected on filters and provides more complete information about corrosion products than commonly used digestive methods of chemical analysis. Recent analyses of CPT specimens from the Darlington Nuclear Generating Station (NGS) primary side and the Bruce B NGS feedwater system are shown as examples. Some characteristics of primary and secondary water circuits are discussed using these new data. (author)

  18. Analysis of diagnostic calorimeter data by the transfer function technique

    Energy Technology Data Exchange (ETDEWEB)

    Delogu, R. S., E-mail: rita.delogu@igi.cnr.it; Pimazzoni, A.; Serianni, G. [Consorzio RFX, Corso Stati Uniti, 35127 Padova (Italy); Poggi, C.; Rossi, G. [Università degli Studi di Padova, Via 8 Febbraio 1848, 35122 Padova (Italy)

    2016-02-15

    This paper describes the analysis procedure applied to the thermal measurements on the rear side of a carbon fibre composite calorimeter with the purpose of reconstructing the energy flux due to an ion beam colliding on the front side. The method is based on the transfer function technique and allows a fast analysis by means of the fast Fourier transform algorithm. Its efficacy has been tested both on simulated and measured temperature profiles: in all cases, the energy flux features are well reproduced and beamlets are well resolved. Limits and restrictions of the method are also discussed, providing strategies to handle issues related to signal noise and digital processing.

  19. FDTD technique based crosstalk analysis of bundled SWCNT interconnects

    International Nuclear Information System (INIS)

    Duksh, Yograj Singh; Kaushik, Brajesh Kumar; Agarwal, Rajendra P.

    2015-01-01

    The equivalent electrical circuit model of a bundled single-walled carbon nanotube based distributed RLC interconnects is employed for the crosstalk analysis. The accurate time domain analysis and crosstalk effect in the VLSI interconnect has emerged as an essential design criteria. This paper presents a brief description of the numerical method based finite difference time domain (FDTD) technique that is intended for estimation of voltages and currents on coupled transmission lines. For the FDTD implementation, the stability of the proposed model is strictly restricted by the Courant condition. This method is used for the estimation of crosstalk induced propagation delay and peak voltage in lossy RLC interconnects. Both functional and dynamic crosstalk effects are analyzed in the coupled transmission line. The effect of line resistance on crosstalk induced delay, and peak voltage under dynamic and functional crosstalk is also evaluated. The FDTD analysis and the SPICE simulations are carried out at 32 nm technology node for the global interconnects. It is observed that the analytical results obtained using the FDTD technique are in good agreement with the SPICE simulation results. The crosstalk induced delay, propagation delay, and peak voltage obtained using the FDTD technique shows average errors of 4.9%, 3.4% and 0.46%, respectively, in comparison to SPICE. (paper)

  20. Characterization of decommissioned reactor internals: Monte Carlo analysis technique

    International Nuclear Information System (INIS)

    Reid, B.D.; Love, E.F.; Luksic, A.T.

    1993-03-01

    This study discusses computer analysis techniques for determining activation levels of irradiated reactor component hardware to yield data for the Department of Energy's Greater-Than-Class C Low-Level Radioactive Waste Program. The study recommends the Monte Carlo Neutron/Photon (MCNP) computer code as the best analysis tool for this application and compares the technique to direct sampling methodology. To implement the MCNP analysis, a computer model would be developed to reflect the geometry, material composition, and power history of an existing shutdown reactor. MCNP analysis would then be performed using the computer model, and the results would be validated by comparison to laboratory analysis results from samples taken from the shutdown reactor. The report estimates uncertainties for each step of the computational and laboratory analyses; the overall uncertainty of the MCNP results is projected to be ±35%. The primary source of uncertainty is identified as the material composition of the components, and research is suggested to address that uncertainty

  1. Engineering and Functional Analysis of Mitotic Kinases Through Chemical Genetics.

    Science.gov (United States)

    Jones, Mathew J K; Jallepalli, Prasad V

    2016-01-01

    During mitosis, multiple protein kinases transform the cytoskeleton and chromosomes into new and highly dynamic structures that mediate the faithful transmission of genetic information and cell division. However, the large number and strong conservation of mammalian kinases in general pose significant obstacles to interrogating them with small molecules, due to the difficulty in identifying and validating those which are truly selective. To overcome this problem, a steric complementation strategy has been developed, in which a bulky "gatekeeper" residue within the active site of the kinase of interest is replaced with a smaller amino acid, such as glycine or alanine. The enlarged catalytic pocket can then be targeted in an allele-specific manner with bulky purine analogs. This strategy provides a general framework for dissecting kinase function with high selectivity, rapid kinetics, and reversibility. In this chapter we discuss the principles and techniques needed to implement this chemical genetic approach in mammalian cells.

  2. A multi-technique chemical characterization of a Stradivari decorated violin top plate

    Science.gov (United States)

    Malagodi, M.; Canevari, C.; Bonizzoni, L.; Galli, A.; Maspero, F.; Martini, M.

    2013-08-01

    This paper focuses on the characterization of the materials of a violin top plate made by Antonio Stradivari (17th century), with different diagnostic techniques and with an integrated and non-destructive analytical methodology to study surface coatings and decorations. The UV-induced visible fluorescence, optical digital microscopy, ED-XRF associated with micro-FTIR spectroscopy analysis, and dendrochronology were performed. The investigations were aimed to identify the presence of original varnish layers and to characterize the composition of the decorations, either the inlaid purflings or the composite false-inlay strip between them. Several results were achieved: (i) evidence of the absence of varnish layers on the surface as a result of extended and inappropriate restoring; (ii) identification of the dye used for the black layers of the purflings; (iii) characterization of the black matrix and the white elements of the decoration. Furthermore, a dendrochronological dating was performed. A copy of the top plate was realized with materials similar to those identified on the Stradivari original; the same analyses performed on the original model were carried out on the same areas of the copy.

  3. Analysis of the chemical equilibrium of combustion at constant volume

    Directory of Open Access Journals (Sweden)

    Marius BREBENEL

    2014-04-01

    Full Text Available Determining the composition of a mixture of combustion gases at a given temperature is based on chemical equilibrium, when the equilibrium constants are calculated on the assumption of constant pressure and temperature. In this paper, an analysis of changes occurring when combustion takes place at constant volume is presented, deriving a specific formula of the equilibrium constant. The simple reaction of carbon combustion in pure oxygen in both cases (constant pressure and constant volume is next considered as example of application, observing the changes occurring in the composition of the combustion gases depending on temperature.

  4. Chemical phase analysis of seed mediated synthesized anisotropic silver nanoparticles

    International Nuclear Information System (INIS)

    Bharti, Amardeep; Goyal, Navdeep; Singh, Suman; Singla, M. L.

    2015-01-01

    Noble-metal nanoparticles are of great interest because of its broad applications almost in every stream (i.e. biology, chemistry and engineering) due to their unique size/shape dependant properties. In this paper, chemical phase of seed mediated synthesized anisotropic silver nanoparticle (AgNPs) has been investigated via fourier transform infrared spectroscopy (FTIR) and thermogravimetric analysis (TGA). These nanaoparticles were synthesized by seed-growth method controlled by urea and dextrose results to highly stable 12-20 nm particle size revealed by zeta potential and transmission electron microscopy (TEM)

  5. Treatment systems for liquid wastes generated in chemical analysis laboratories

    International Nuclear Information System (INIS)

    Linda Berrio; Oscar Beltran; Edison Agudelo; Santiago Cardona

    2012-01-01

    Nowadays, handling of liquid wastes from chemical analysis laboratories is posing problems to different public and private organizations because of its requirements of an integrated management. This article reviews various treatment technologies and its removal efficiencies in order to establish criteria for selecting the system and the appropriate variables to achieve research objectives as well as environmental sustainability. Review begins with a description of the problem and continues with the study of treatments for laboratory wastes. These technologies are segregated into physicochemical and biological treatments that comprise a variety of processes, some of which are considered in this review.

  6. Chemical analysis of dairy cattle feed from Brazil

    International Nuclear Information System (INIS)

    Luis Gustavo Cofani dos Santos; De Nadai Fernandes, E.A.; Marcio Arruda Bacchi; Lucimara Blumer; Gabriel Adrian Sarries; Fernando Barbosa Junior

    2009-01-01

    The bovine dairy cattle demand diets of high nutritional value being essential to know chemical composition of feed supplied to cows to achieve high levels of quality, safety and productivity of milk. Different roughages and concentrates from Minas Gerais and Rio Grande do Sul states, Brazil, were analyzed by instrumental neutron activation analysis (INAA) and inductively coupled plasma mass spectrometry (ICP-MS). Concentrate and roughage samples were differentiated by mass fractions of As, Ba, Mg, P, Rb and Sr. Samples of concentrate from both origins were differentiated by mass fractions of As, Cd, Co, Cr, Cs, Ni and Rb. (author)

  7. Integrated polymer waveguides for absorbance detection in chemical analysis systems

    DEFF Research Database (Denmark)

    Mogensen, Klaus Bo; El-Ali, Jamil; Wolff, Anders

    2003-01-01

    A chemical analysis system for absorbance detection with integrated polymer waveguides is reported for the first time. The fabrication procedure relies on structuring of a single layer of the photoresist SU-8, so both the microfluidic channel network and the optical components, which include planar....... The emphasis of this paper is on the signal-to-noise ratio of the detection and its relation to the sensitivity. Two absorbance cells with an optical path length of 100 μm and 1000 μm were characterized and compared in terms of sensitivity, limit of detection and effective path length for measurements...

  8. Imaging, structural, and chemical analysis of silicon nanowires

    International Nuclear Information System (INIS)

    Barsotti, R.J. Jr.; Fischer, J.E.; Lee, C.H.; Mahmood, J.; Adu, C.K.W.; Eklund, P.C.

    2002-01-01

    Laser ablation has been used to grow silicon nanowires with an average silicon crystal core diameter of 6.7 nm±2.9 nm surrounded by an amorphous SiO x sheath of 1-2 nm, the smallest silicon wires reported in the literature. Imaging, chemical, and structural analysis of these wires are reported. Due to the growth temperature and the presence of calcium impurities and trace oxygen, two distinct types of wires are found. They appear to grow by two different processes. One requires a metal catalyst, the other is catalyzed by oxygen. Suggestions for controlled synthesis based on these growth mechanisms are made

  9. Determination of air pollutants by nuclear chemical analysis

    International Nuclear Information System (INIS)

    Lesny, J.; Toelgyessy, J.

    1975-01-01

    Nuclear analytical methods are discussed with a view to their applicability in the determination of air pollutants. It is shown that some methods (use of radioactive kryptonates in automatic analyzers, application of activation analysis, X-ray fluorescence methods) are developed in theory and proven in practice in such an extent to be widely used in the near future in the control of the environment. Many other methods are becoming increasingly important for the solution of specific problems of environmental protection (such as the control of sudden environmental contamination in the proximity of chemical plants and industrial centers). (author)

  10. Crystal-Chemical Analysis of Soil at Rocknest, Gale Crater

    Science.gov (United States)

    Morrison, S. M.; Downs, R. T.; Blake, D. F.; Bish, D. L.; Ming, D. W.; Morris, R. V.; Yen, A. S.; Chipera, S. J.; Treiman, A. H.; Vaniman, D. T.; hide

    2013-01-01

    The CheMin instrument on the Mars Science Laboratory rover Curiosity performed X-ray diffraction analysis on Martian soil [1] at Rocknest in Gale Crater. In particular, crystalline phases from scoop 5 were identified and analyzed with the Rietveld method [2]. Refined unit-cell parameters are reported in Table 1. Comparing these unit-cell parameters with those in the literature provides an estimate of the chemical composition of the crystalline phases. For instance, Fig. 1 shows the Mg-content of Fa-Fo olivine as a function of the b unit-cell parameter using literature data. Our refined b parameter is indicated by the black triangle.

  11. Physcio chemical analysis of browning inhibitors treated solanum turberosum powder

    International Nuclear Information System (INIS)

    Alizai, M.N.K.; Abid, H.

    2008-01-01

    White potatoes (Solanum turberosum) were procured from agriculture Research Institute Tarnab Farm Peshawar to use for the preparation of potato powder. The process involves sorting. Washing, peeling slicing, blanching, treating with poly phenol oxidase inhibitors, dehydration, grinding and packing. All these parameters used in process were standardized. Chemical analysis of fresh potato and potato powder were carried out. Microbiological examination, functional properties and storage life studies of the potato powder were also performed. The product prepared by drying in cabinet dryer at 55 C for 7 hours was off white colour potatoes chips which was grinded to make off white potato powder. The potato powder possessed taste and texture. (author)

  12. Crystal-Chemical Analysis Martian Minerals in Gale Crater

    Science.gov (United States)

    Morrison, S. M.; Downs, R. T.; Blake, D. F.; Bish, D. L.; Ming, D. W.; Morris, R. V.; Yen, A. S.; Chipera, S. J.; Treiman, A. H.; Vaniman, D. T.; hide

    2015-01-01

    The CheMin instrument on the Mars Science Laboratory rover Curiosity performed X-ray diffraction analyses on scooped soil at Rocknest and on drilled rock fines at Yellowknife Bay (John Klein and Cumberland samples), The Kimberley (Windjana sample), and Pahrump (Confidence Hills sample) in Gale crater, Mars. Samples were analyzed with the Rietveld method to determine the unit-cell parameters and abundance of each observed crystalline phase. Unit-cell parameters were used to estimate compositions of the major crystalline phases using crystal-chemical techniques. These phases include olivine, plagioclase and clinopyroxene minerals. Comparison of the CheMin sample unit-cell parameters with those in the literature provides an estimate of the chemical compositions of the major crystalline phases. Preliminary unit-cell parameters, abundances and compositions of crystalline phases found in Rocknest and Yellowknife Bay samples were reported in. Further instrument calibration, development of 2D-to- 1D pattern conversion corrections, and refinement of corrected data allows presentation of improved compositions for the above samples.

  13. Analytical technique to address terrorist threats by chemical weapons of mass destruction

    Science.gov (United States)

    Dempsey, Patrick M.

    1997-01-01

    Terrorism is no longer an issue without effect on the American mind. We now live with the same concerns and fears that have been commonplace in other developed and third world countries for a long time. Citizens of other countries have long lived with the specter of terrorism and now the U.S. needs to be concerned and prepared for terrorist activities.T he terrorist has the ability to cause great destructive effects by focusing their effort on unaware and unprepared civilian populations. Attacks can range from simple explosives to sophisticated nuclear, chemical and biological weapons. Intentional chemical releases of hazardous chemicals or chemical warfare agents pose a great threat because of their ready availability and/or ease of production, and their ability to cause widespread damage. As this battlefront changes from defined conflicts and enemies to unnamed terrorists, we must implement the proper analytical tools to provide a fast and efficient response. Each chemical uses in a terrorists weapon leaves behind a chemical signature that can be used to identify the materials involved and possibly lead investigators to the source and to those responsible. New tools to provide fast and accurate detection for battlefield chemical and biological agent attack are emerging. Gas chromatography/mass spectrometry (GC/MS) is one of these tools that has found increasing use by the military to respond to chemical agent attacks. As the technology becomes smaller and more portable, it can be used by law enforcement personnel to identify suspected terrorist releases and to help prepare the response; define contaminated areas for evacuation and safety concerns, identify the proper treatment of exposed or affected civilians, and suggest decontamination and cleanup procedures.

  14. QUALITY ASSURANCE GUIDELINES FOR LABORATORIES PERFORMING FORENSIC ANALYSIS OF CHEMICAL TERRORISM

    Science.gov (United States)

    The Scientific Working Group on Forensic Analysis of Chemical Terrorism (SWGFACT) has developed the following quality assurance guidelines to provide laboratories engaged in forensic analysis of chemical evidence associated with terrorism a framework to implement a quality assura...

  15. Application of quantum dots as analytical tools in automated chemical analysis: A review

    International Nuclear Information System (INIS)

    Frigerio, Christian; Ribeiro, David S.M.; Rodrigues, S. Sofia M.; Abreu, Vera L.R.G.; Barbosa, João A.C.; Prior, João A.V.; Marques, Karine L.; Santos, João L.M.

    2012-01-01

    Highlights: ► Review on quantum dots application in automated chemical analysis. ► Automation by using flow-based techniques. ► Quantum dots in liquid chromatography and capillary electrophoresis. ► Detection by fluorescence and chemiluminescence. ► Electrochemiluminescence and radical generation. - Abstract: Colloidal semiconductor nanocrystals or quantum dots (QDs) are one of the most relevant developments in the fast-growing world of nanotechnology. Initially proposed as luminescent biological labels, they are finding new important fields of application in analytical chemistry, where their photoluminescent properties have been exploited in environmental monitoring, pharmaceutical and clinical analysis and food quality control. Despite the enormous variety of applications that have been developed, the automation of QDs-based analytical methodologies by resorting to automation tools such as continuous flow analysis and related techniques, which would allow to take advantage of particular features of the nanocrystals such as the versatile surface chemistry and ligand binding ability, the aptitude to generate reactive species, the possibility of encapsulation in different materials while retaining native luminescence providing the means for the implementation of renewable chemosensors or even the utilisation of more drastic and even stability impairing reaction conditions, is hitherto very limited. In this review, we provide insights into the analytical potential of quantum dots focusing on prospects of their utilisation in automated flow-based and flow-related approaches and the future outlook of QDs applications in chemical analysis.

  16. Yield of Peas Treated with Compost and Chemical Fertilizer Using 15N Technique

    International Nuclear Information System (INIS)

    El-Degwy, S.M.A.

    2011-01-01

    A field experiment was carried out to evaluate the yield of peas treated with organic compost and mineral N fertilizer under sandy soil conditions. The obtained results showed that all the tested vegetative growth parameters, i.e. fresh and dry weight of leaves, root and pods of pea plants, were significantly increased with increasing the levels of mineral N fertilizer from 20 up to 50 kg N ha-1 either solely or in combination with compost. Nitrogen, phosphorus and potassium uptake by pea plants were ranked as follow: chemical N fertilize > compost + chemical N fertilize > compost. Organic additives either alone or in combination with chemical fertilizer had enhanced Ndff uptake by pods over aerial parts and roots while reversible trend was noticed with sole application of chemical fertilizer. Nitrogen derived from compost (Ndfc) and uptake by aerial parts followed by pods were enhanced by addition of organic plus chemical fertilizers comparable to sole addition of organic compost. In other term, chemical fertilizer had enhanced the portion of N derived from organic compost

  17. Phthalic Acid Chemical Probes Synthesized for Protein-Protein Interaction Analysis

    Directory of Open Access Journals (Sweden)

    Chin-Jen Wu

    2013-06-01

    Full Text Available Plasticizers are additives that are used to increase the flexibility of plastic during manufacturing. However, in injection molding processes, plasticizers cannot be generated with monomers because they can peel off from the plastics into the surrounding environment, water, or food, or become attached to skin. Among the various plasticizers that are used, 1,2-benzenedicarboxylic acid (phthalic acid is a typical precursor to generate phthalates. In addition, phthalic acid is a metabolite of diethylhexyl phthalate (DEHP. According to Gene_Ontology gene/protein database, phthalates can cause genital diseases, cardiotoxicity, hepatotoxicity, nephrotoxicity, etc. In this study, a silanized linker (3-aminopropyl triethoxyslane, APTES was deposited on silicon dioxides (SiO2 particles and phthalate chemical probes were manufactured from phthalic acid and APTES–SiO2. These probes could be used for detecting proteins that targeted phthalic acid and for protein-protein interactions. The phthalic acid chemical probes we produced were incubated with epithelioid cell lysates of normal rat kidney (NRK-52E cells to detect the interactions between phthalic acid and NRK-52E extracted proteins. These chemical probes interacted with a number of chaperones such as protein disulfide-isomerase A6, heat shock proteins, and Serpin H1. Ingenuity Pathways Analysis (IPA software showed that these chemical probes were a practical technique for protein-protein interaction analysis.

  18. Comparison of descriptive sensory analysis and chemical analysis for oxidative changes in milk

    DEFF Research Database (Denmark)

    Hedegaard, R V; Kristensen, D; Nielsen, Jacob Holm

    2006-01-01

    and lipolytic changes occurring in the milk during chill storage for 4 d. Sensory analysis and chemical analysis showed high correlation between the typical descriptors for oxidation such as cardboard, metallic taste, and boiled milk and specific chemical markers for oxidation such as hexanal. Notably, primary......Oxidation in 3 types of bovine milk with different fatty acid profiles obtained through manipulation of feed was evaluated by analytical methods quantifying the content of potential antioxidants, the tendency of formation of free radicals, and the accumulation of primary and secondary oxidation...... products. The milk samples were evaluated in parallel by descriptive sensory analysis by a trained panel, and the correlation between the chemical analysis and the descriptive sensory analysis was evaluated. The fatty acid composition of the 3 types of milk was found to influence the oxidative...

  19. Comparison of descriptive sensory analysis and chemical analysis for oxidative changes in milk

    DEFF Research Database (Denmark)

    Hedegaard, Rikke Susanne Vingborg; Kristensen, D.; Nielsen, J. H.

    2006-01-01

    products. The milk samples were evaluated in parallel by descriptive sensory analysis by a trained panel, and the correlation between the chemical analysis and the descriptive sensory analysis was evaluated. The fatty acid composition of the 3 types of milk was found to influence the oxidative...... and lipolytic changes occurring in the milk during chill storage for 4 d. Sensory analysis and chemical analysis showed high correlation between the typical descriptors for oxidation such as cardboard, metallic taste, and boiled milk and specific chemical markers for oxidation such as hexanal. Notably, primary...... oxidation products (i.e., lipid hydroperoxides) and even the tendency of formation of radicals as measured by electron spin resonance spectroscopy were also highly correlated to the sensory descriptors for oxidation. Electron spin resonance spectroscopy should accordingly be further explored as a routine...

  20. Improved Tandem Measurement Techniques for Aerosol Particle Analysis

    Science.gov (United States)

    Rawat, Vivek Kumar

    Non-spherical, chemically inhomogeneous (complex) nanoparticles are encountered in a number of natural and engineered environments, including combustion systems (which produces highly non-spherical aggregates), reactors used in gas-phase materials synthesis of doped or multicomponent materials, and in ambient air. These nanoparticles are often highly diverse in size, composition and shape, and hence require determination of property distribution functions for accurate characterization. This thesis focuses on development of tandem mobility-mass measurement techniques coupled with appropriate data inversion routines to facilitate measurement of two dimensional size-mass distribution functions while correcting for the non-idealities of the instruments. Chapter 1 provides the detailed background and motivation for the studies performed in this thesis. In chapter 2, the development of an inversion routine is described which is employed to determine two dimensional size-mass distribution functions from Differential Mobility Analyzer-Aerosol Particle Mass analyzer tandem measurements. Chapter 3 demonstrates the application of the two dimensional distribution function to compute cumulative mass distribution function and also evaluates the validity of this technique by comparing the calculated total mass concentrations to measured values for a variety of aerosols. In Chapter 4, this tandem measurement technique with the inversion routine is employed to analyze colloidal suspensions. Chapter 5 focuses on application of a transverse modulation ion mobility spectrometer coupled with a mass spectrometer to study the effect of vapor dopants on the mobility shifts of sub 2 nm peptide ion clusters. These mobility shifts are then compared to models based on vapor uptake theories. Finally, in Chapter 6, a conclusion of all the studies performed in this thesis is provided and future avenues of research are discussed.

  1. Different techniques of multispectral data analysis for vegetation fraction retrieval

    Science.gov (United States)

    Kancheva, Rumiana; Georgiev, Georgi

    2012-07-01

    Vegetation monitoring is one of the most important applications of remote sensing technologies. In respect to farmlands, the assessment of crop condition constitutes the basis of growth, development, and yield processes monitoring. Plant condition is defined by a set of biometric variables, such as density, height, biomass amount, leaf area index, and etc. The canopy cover fraction is closely related to these variables, and is state-indicative of the growth process. At the same time it is a defining factor of the soil-vegetation system spectral signatures. That is why spectral mixtures decomposition is a primary objective in remotely sensed data processing and interpretation, specifically in agricultural applications. The actual usefulness of the applied methods depends on their prediction reliability. The goal of this paper is to present and compare different techniques for quantitative endmember extraction from soil-crop patterns reflectance. These techniques include: linear spectral unmixing, two-dimensional spectra analysis, spectral ratio analysis (vegetation indices), spectral derivative analysis (red edge position), colorimetric analysis (tristimulus values sum, chromaticity coordinates and dominant wavelength). The objective is to reveal their potential, accuracy and robustness for plant fraction estimation from multispectral data. Regression relationships have been established between crop canopy cover and various spectral estimators.

  2. CHEMICALS

    CERN Multimedia

    Medical Service

    2002-01-01

    It is reminded that all persons who use chemicals must inform CERN's Chemistry Service (TIS-GS-GC) and the CERN Medical Service (TIS-ME). Information concerning their toxicity or other hazards as well as the necessary individual and collective protection measures will be provided by these two services. Users must be in possession of a material safety data sheet (MSDS) for each chemical used. These can be obtained by one of several means : the manufacturer of the chemical (legally obliged to supply an MSDS for each chemical delivered) ; CERN's Chemistry Service of the General Safety Group of TIS ; for chemicals and gases available in the CERN Stores the MSDS has been made available via EDH either in pdf format or else via a link to the supplier's web site. Training courses in chemical safety are available for registration via HR-TD. CERN Medical Service : TIS-ME :73186 or service.medical@cern.ch Chemistry Service : TIS-GS-GC : 78546

  3. A comparison of approximation techniques for variance-based sensitivity analysis of biochemical reaction systems

    Directory of Open Access Journals (Sweden)

    Goutsias John

    2010-05-01

    Full Text Available Abstract Background Sensitivity analysis is an indispensable tool for the analysis of complex systems. In a recent paper, we have introduced a thermodynamically consistent variance-based sensitivity analysis approach for studying the robustness and fragility properties of biochemical reaction systems under uncertainty in the standard chemical potentials of the activated complexes of the reactions and the standard chemical potentials of the molecular species. In that approach, key sensitivity indices were estimated by Monte Carlo sampling, which is computationally very demanding and impractical for large biochemical reaction systems. Computationally efficient algorithms are needed to make variance-based sensitivity analysis applicable to realistic cellular networks, modeled by biochemical reaction systems that consist of a large number of reactions and molecular species. Results We present four techniques, derivative approximation (DA, polynomial approximation (PA, Gauss-Hermite integration (GHI, and orthonormal Hermite approximation (OHA, for analytically approximating the variance-based sensitivity indices associated with a biochemical reaction system. By using a well-known model of the mitogen-activated protein kinase signaling cascade as a case study, we numerically compare the approximation quality of these techniques against traditional Monte Carlo sampling. Our results indicate that, although DA is computationally the most attractive technique, special care should be exercised when using it for sensitivity analysis, since it may only be accurate at low levels of uncertainty. On the other hand, PA, GHI, and OHA are computationally more demanding than DA but can work well at high levels of uncertainty. GHI results in a slightly better accuracy than PA, but it is more difficult to implement. OHA produces the most accurate approximation results and can be implemented in a straightforward manner. It turns out that the computational cost of the

  4. Gas chromatographic isolation technique for compound-specific radiocarbon analysis

    International Nuclear Information System (INIS)

    Uchida, M.; Kumamoto, Y.; Shibata, Y.; Yoneda, M.; Morita, M.; Kawamura, K.

    2002-01-01

    Full text: We present here a gas chromatographic isolation technique for the compound-specific radiocarbon analysis of biomarkers from the marine sediments. The biomarkers of fatty acids, hydrocarbon and sterols were isolated with enough amount for radiocarbon analysis using a preparative capillary gas chromatograph (PCGC) system. The PCGC systems used here is composed of an HP 6890 GC with FID, a cooled injection system (CIS, Gerstel, Germany), a zero-dead-volume effluent splitter, and a cryogenic preparative collection device (PFC, Gerstel). For AMS analysis, we need to separate and recover sufficient quantity of target individual compounds (>50 μgC). Yields of target compounds from C 14 n-alkanes to C 40 to C 30 n-alkanes and approximately that of 80% for higher molecular weights compounds more than C 30 n-alkanes. Compound specific radiocarbon analysis of organic compounds, as well as compound-specific stable isotope analysis, provide valuable information on the origins and carbon cycling in marine system. Above PCGC conditions, we applied compound-specific radiocarbon analysis to the marine sediments from western north Pacific, which showed the possibility of a useful chronology tool for estimating the age of sediment using organic matter in paleoceanographic study, in the area where enough amounts of planktonic foraminifera for radiocarbon analysis by accelerator mass spectrometry (AMS) are difficult to obtain due to dissolution of calcium carbonate. (author)

  5. Image Analysis Technique for Material Behavior Evaluation in Civil Structures

    Science.gov (United States)

    Moretti, Michele; Rossi, Gianluca

    2017-01-01

    The article presents a hybrid monitoring technique for the measurement of the deformation field. The goal is to obtain information about crack propagation in existing structures, for the purpose of monitoring their state of health. The measurement technique is based on the capture and analysis of a digital image set. Special markers were used on the surface of the structures that can be removed without damaging existing structures as the historical masonry. The digital image analysis was done using software specifically designed in Matlab to follow the tracking of the markers and determine the evolution of the deformation state. The method can be used in any type of structure but is particularly suitable when it is necessary not to damage the surface of structures. A series of experiments carried out on masonry walls of the Oliverian Museum (Pesaro, Italy) and Palazzo Silvi (Perugia, Italy) have allowed the validation of the procedure elaborated by comparing the results with those derived from traditional measuring techniques. PMID:28773129

  6. ANALYSIS OF CHEMICAL COMPOUNDS DISTINGUISHER FOR AGARWOOD QUALITIES

    Directory of Open Access Journals (Sweden)

    Gunawan Trisandi Pasaribu

    2015-04-01

    Full Text Available Gaharu (Agarwood is described as a fragrant-smelling wood that is usually derived from the trunk of the genus Aquilaria and Gyrinops (both of the family Thymelaeaceae, which have been infected by a particular disease. Based on Indonesian National Standard, agarwood can be classified into various grades, i.e. gubal gaharu, kemedangan and serbuk gaharu. The grading system is based on the color, weight and odor. It seems that such a grading is too subjective for agarwood classification. Therefore, to minimize the subjectivity, more objective agarwood grading is required, which incorporates its chemical composition and resin content. This research was conducted focusing on the analysis of the particular grade of agarwood originating from West Sumatra. The different types of agarwood qualities are: kemedangan C, teri C, kacangan C and super AB. Initially, the obtained agarwood samples were grounded to powder, extracted on a Soxhlet extractor using various organic solvents (i.e. n-hexane, acetone, and methanol. The agarwood-acetone extracts were analyzed using GC-MS to determine its chemical composition. The results showed a positive, linier relationship in which the resin yield increased with the increase in agarwood quality grades. GC-MS analysis revealed that several sesquiterpene groups can be found in kemedangan C, teri C, kacangan C and super AB qualities. It is interesting that aromadendrene could be identified or found in all agarwood quality grades. Therefore, it is presumed that the aromadendrene compounds can act as an effective chemical distinguisher for agarwood, whereby the greater the aromadendrene content, the better is the agarwood grade.

  7. [Construction of chemical information database based on optical structure recognition technique].

    Science.gov (United States)

    Lv, C Y; Li, M N; Zhang, L R; Liu, Z M

    2018-04-18

    To create a protocol that could be used to construct chemical information database from scientific literature quickly and automatically. Scientific literature, patents and technical reports from different chemical disciplines were collected and stored in PDF format as fundamental datasets. Chemical structures were transformed from published documents and images to machine-readable data by using the name conversion technology and optical structure recognition tool CLiDE. In the process of molecular structure information extraction, Markush structures were enumerated into well-defined monomer molecules by means of QueryTools in molecule editor ChemDraw. Document management software EndNote X8 was applied to acquire bibliographical references involving title, author, journal and year of publication. Text mining toolkit ChemDataExtractor was adopted to retrieve information that could be used to populate structured chemical database from figures, tables, and textual paragraphs. After this step, detailed manual revision and annotation were conducted in order to ensure the accuracy and completeness of the data. In addition to the literature data, computing simulation platform Pipeline Pilot 7.5 was utilized to calculate the physical and chemical properties and predict molecular attributes. Furthermore, open database ChEMBL was linked to fetch known bioactivities, such as indications and targets. After information extraction and data expansion, five separate metadata files were generated, including molecular structure data file, molecular information, bibliographical references, predictable attributes and known bioactivities. Canonical simplified molecular input line entry specification as primary key, metadata files were associated through common key nodes including molecular number and PDF number to construct an integrated chemical information database. A reasonable construction protocol of chemical information database was created successfully. A total of 174 research

  8. Microbiological and chemical analysis of land snails commercialised in Sicily

    Directory of Open Access Journals (Sweden)

    Antonello Cicero

    2015-05-01

    Full Text Available In this study 160 samples of snails belonging to the species Helix aspersa maxima and Helix aspersa muller were examined for chemical and microbiological analysis. Samples came from Greece and Poland. Results showed mean concentration of cadmium (0.35±0.036 mg/kg and lead (0.05±0.013 mg/kg much higher than the limit of detection. Mercury levels in both species were not detected. Microbiological analysis revealed the absence of Salmonella spp. and Clostridium spp. in both examined species. E. coli and K. oxytoca were observed in Helix aspersa maxima and Helix aspersa muller. Furthermore, one case of fungi positivity in samples of Helix aspersa muller was found. The reported investigations highlight the need to create and adopt a reference legislation to protect the health of consumers.

  9. Chemical analysis for waste management in paint industries

    International Nuclear Information System (INIS)

    Nawaz, Z.; Naveed, S.; Shiekh, N.A.; Sagheer, K.

    2005-01-01

    The chemical analysis of paint industries waste has been carried out; the main emission sources are the heating of raw materials and lacquer. Also the waste from other applications and production contains high concentration of heavy metals, VOC's, COD, TDS with notable acidity and alkalinity. Based on the analysis it was observed that the major losses of production could be minimized. Further toxic effects of the waste material can be minimized. In this reference measures to minimize production losses should be adopted along with the proper management. These laboratory results also lead to the areas of emissions and waste production during manufacturing process. Solutions have been proposed for process development and integrated waste minimization. (author)

  10. Fault tree technique: advances in probabilistic and logical analysis

    International Nuclear Information System (INIS)

    Clarotti, C.A.; Amendola, A.; Contini, S.; Squellati, G.

    1982-01-01

    Fault tree reliability analysis is used for assessing the risk associated to systems of increasing complexity (phased mission systems, systems with multistate components, systems with non-monotonic structure functions). Much care must be taken to make sure that fault tree technique is not used beyond its correct validity range. To this end a critical review of mathematical foundations of reliability fault tree analysis is carried out. Limitations are enlightened and potential solutions to open problems are suggested. Moreover an overview is given on the most recent developments in the implementation of an integrated software (SALP-MP, SALP-NOT, SALP-CAFT Codes) for the analysis of a wide class of systems

  11. Temperature analysis of laser ignited metalized material using spectroscopic technique

    Science.gov (United States)

    Bassi, Ishaan; Sharma, Pallavi; Daipuriya, Ritu; Singh, Manpreet

    2018-05-01

    The temperature measurement of the laser ignited aluminized Nano energetic mixture using spectroscopy has a great scope in in analysing the material characteristic and combustion analysis. The spectroscopic analysis helps to do in depth study of combustion of materials which is difficult to do using standard pyrometric methods. Laser ignition was used because it consumes less energy as compared to electric ignition but ignited material dissipate the same energy as dissipated by electric ignition and also with the same impact. Here, the presented research is primarily focused on the temperature analysis of energetic material which comprises of explosive material mixed with nano-material and is ignited with the help of laser. Spectroscopy technique is used here to estimate the temperature during the ignition process. The Nano energetic mixture used in the research does not comprise of any material that is sensitive to high impact.

  12. Investigation of geothermal fields in himalayan range in pakistan using isotope and chemical techniques

    International Nuclear Information System (INIS)

    Ahmad, M.; Sheikh, M.R.; Akram, W.; Tasneem, M.A.; Iqbal, N.; Latif, Z.

    2007-07-01

    There are many geothermal sites in Himalayan belt of Pakistan having low to high temperatures(boiling water). Isotopes and geochemical techniques were applied to investigate the origin, subsurface history and reservoir temperatures of geothermal fields at Tatta Pani and Tato lying along Main Mantle Thrust, Murtazabad along Main Karakoram Thrust and Kotli in the area of overlapping thrusts: Punjal Thrust, Main Boundary Thrust and the Himalaya Frontal Thrust. Discharge of the springs varies from 30 to 2000 liters per minute with the surface temperature from 47.3 to 92 degree C. Two sets of water samples were collected from these fields. The samples were analyzed for various isotopes (O/sup 18/, H/sup 2/ and H/sup 3/ of water; C/sup 13/ of dissolved inorganic carbon; S/sup 34/ and O/sup 18/ of dissolved sulphates); and water chemistry. The thermal waters of the Northern Areas of Pakistan are generally neutral to slightly alkaline and have low dissolved contents. Sodium is the dominant cation in all the cases. In terms of anions, HCO/sub 3/ is dominating. Source of recharge is meteoric water (rains and/or snow-melt). The dominant process of cooling is conduction at Tatta Pani, Tato, and Murtazabad. Shallow groundwater is mixing with the thermal springs in different proportions at Murtazabad, while there is no mixing in the thermal waters of Tatta Pani and Tato. The equilibrium temperature of the thermal end-member at Murtazabad is in the range of 185- 225 degree C and the isochemical-mixing model based on the Na-K and quartz geothermometers estimates 227 degree C temperature. O/sup 18/ (SO/sub 4/-H/sub 2/O) geothermometer indicates equilibrium temperatures (before mixing) above I85 degree C. The dissolved silica vs. enthalpy plot suggests heat losses through conduction from the original temperature about 245 degree C. The reservoir temperatures of Tatta Pani (100-130 degree C) determined by the Na-K, K-Mg and quartz geothermometers are in good agreement. O/sup 18/ (SO

  13. Determination of mercury in ppb level by activation analysis and chemical separation

    International Nuclear Information System (INIS)

    Requejo, C.S.

    1983-02-01

    A method for determining mercury in steel samples was developed. Activation analysis using thermal neutrons, followed by radiochemical separations to eliminate 75 Se interferences, were applied. Sixty hours after the end of the irradiation, the samples were processed and distillation of mercury and selenium bromides were carried out. Selenium was separated as an element and mercury sulfide was precipitaded. The chemical separation procedure was tested by using a tracer technique; the recovery yield was 99,2% + - 2,7%. (C.L.B.) [pt

  14. Improvement and verification of fast reactor safety analysis techniques

    International Nuclear Information System (INIS)

    Jackson, J.F.

    1975-01-01

    An initial analysis of the KIWI-TNT experiment using the VENUS-II disassembly code has been completed. The calculated fission energy release agreed with the experimental value to within about 3 percent. An initial model for analyzing the SNAPTRAN-2 core disassembly experiment was also developed along with an appropriate equation-of-state. The first phase of the VENUS-II/PAD comparison study was completed through the issuing of a preliminary report describing the results. A new technique to calculate a P-V-work curve as a function of the degree of core expansion following a disassembly excursion has been developed. The technique provides results that are consistent with the ANL oxide-fuel equation-of-state in VENUS-II. Evaluation and check-out of this new model are currently in progress

  15. On discriminant analysis techniques and correlation structures in high dimensions

    DEFF Research Database (Denmark)

    Clemmensen, Line Katrine Harder

    This paper compares several recently proposed techniques for performing discriminant analysis in high dimensions, and illustrates that the various sparse methods dier in prediction abilities depending on their underlying assumptions about the correlation structures in the data. The techniques...... the methods in two: Those who assume independence between the variables and thus use a diagonal estimate of the within-class covariance matrix, and those who assume dependence between the variables and thus use an estimate of the within-class covariance matrix, which also estimates the correlations between...... variables. The two groups of methods are compared and the pros and cons are exemplied using dierent cases of simulated data. The results illustrate that the estimate of the covariance matrix is an important factor with respect to choice of method, and the choice of method should thus be driven by the nature...

  16. Some problems of calibration technique in charged particle activation analysis

    International Nuclear Information System (INIS)

    Krasnov, N.N.; Zatolokin, B.V.; Konstantinov, I.O.

    1977-01-01

    It is shown that three different approaches to calibration technique based on the use of average cross-section, equivalent target thickness and thick target yield are adequate. Using the concept of thick target yield, a convenient charged particle activation equation is obtained. The possibility of simultaneous determination of two impurities, from which the same isotope is formed, is pointed out. The use of the concept of thick target yield facilitates the derivation of a simple formula for an absolute and comparative methods of analysis. The methodical error does not exceed 10%. Calibration technique and determination of expected sensitivity based on the thick target yield concept is also very convenient because experimental determination of thick target yield values is a much simpler procedure than getting activation curve or excitation function. (T.G.)

  17. Ion beam analysis and spectrometry techniques for Cultural Heritage studies

    International Nuclear Information System (INIS)

    Beck, L.

    2013-01-01

    The implementation of experimental techniques for the characterisation of Cultural heritage materials has to take into account some requirements. The complexity of these past materials requires the development of new techniques of examination and analysis, or the transfer of technologies developed for the study of advanced materials. In addition, due to precious aspect of artwork it is also necessary to use the non-destructive methods, respecting the integrity of objects. It is for this reason that the methods using radiations and/or particles play a important role in the scientific study of art history and archaeology since their discovery. X-ray and γ-ray spectrometry as well as ion beam analysis (IBA) are analytical tools at the service of Cultural heritage. This report mainly presents experimental developments for IBA: PIXE, RBS/EBS and NRA. These developments were applied to the study of archaeological composite materials: layered materials or mixtures composed of organic and non-organic phases. Three examples are shown: evolution of silvering techniques for the production of counterfeit coinage during the Roman Empire and in the 16. century, the characterization of composites or mixed mineral/organic compounds such as bone and paint. In these last two cases, the combination of techniques gave original results on the proportion of both phases: apatite/collagen in bone, pigment/binder in paintings. Another part of this report is then dedicated to the non-invasive/non-destructive characterization of prehistoric pigments, in situ, for rock art studies in caves and in the laboratory. Finally, the perspectives of this work are presented. (author) [fr

  18. The approach to risk analysis in three industries: nuclear power, space systems, and chemical process

    International Nuclear Information System (INIS)

    Garrick, B.J.

    1988-01-01

    The aerospace, nuclear power, and chemical processing industries are providing much of the incentive for the development and application of advanced risk analysis techniques to engineered systems. Risk analysis must answer three basic questions: What can go wrong? How likely is it? and What are the consequences? The result of such analyses is not only a quantitative answer to the question of 'What is the risk', but, more importantly, a framework for intelligent and visible risk management. Because of the societal importance of the subject industries and the amount of risk analysis activity involved in each, it is interesting to look for commonalities, differences, and, hopefully, a basis for some standardization. Each industry has its strengths: the solid experience base of the chemical industry, the extensive qualification and testing procedures of the space industry, and the integrative and quantitative risk and reliability methodologies developed for the nuclear power industry. In particular, most advances in data handling, systems interaction modeling, and uncertainty analysis have come from the probabilistic risk assessment work in the nuclear safety field. In the final analysis, all three industries would greatly benefit from a more deliberate technology exchange program in the rapidly evolving discipline of quantitative risk analysis. (author)

  19. Mass spectrographic analysis of selected chemical elements by microbial leaching of zircon

    International Nuclear Information System (INIS)

    Becker, S.; Dietze, H.J.; Bullmann, M.; Iske, U.

    1986-01-01

    Spark source mass spectrometry is a useful method for chemical element analysis of geological and biological samples. This sensitive technique (detection limit down to the ppb-range) is used to analyze leaching processes by means of several microorganisms. The problem of microbial leaching of chemical resistent materials was tested under laboratory conditions with regard to possible analytical and technical applications. Leaching of metals with chemolithotrophic and heterotrophic, organic acids producing microorganisms has been investigated with zircon from the Baltic Shield containing 0.7% rare earth elements and 1.67% hafnium. When zircon is leached with strains of thiobacillus ferrooxidans about 80% of the rare earth elements, Hf, Th and U can be recovered. (orig.) [de

  20. Safety- and Risk Analysis Activities in Chemical Industry in Europe

    International Nuclear Information System (INIS)

    Kozine, Igor; Duijm, Nijs Jan; Lauridsen Kurt

    2001-01-01

    The current paper gives an overview of the legislation and the methods used in safety and risk management in the chemical industry within Europe and in particular within the European Union. The paper is based on a report that has been written for the SOS-1 project under the Nordic nuclear safety research (NKS). Safety- and risk-related matters in the process industry, in particular, in chemical, within the EU are subject to consideration at three levels: (1) EU legislation, (2) European/intemational standardisation, and (3) socio-economic analysis. EC Directives define the 'essential requirements', e.g., protection of health and safety, that must be fulfilled when goods are placed on the market or some industry is put into operation. The European standards bodies (CEN, CENELEC and ETSI) have the task of establishing the corresponding technical specifications, meeting the essential requirements of the Directives, compliance with which will provide a presumption of conformity with the essential requirements. Such specifications are referred to as 'harmonised standards'. Compliance with harmonised standards remains voluntary, and manufacturers are free to choose any other technical solution that provides compliance with the essential requirements. This view is stated in the 'New Approach' to technical harmonisation and standardisation (details can be found on the web page: http://europe.eu.int/comm/enterprise/newapproach/standardization/index .html). Standardisation as well as the regulation of technical risks is increasingly being undertaken at European or international level. The European legislator limits its role to the affirmation of overall objectives, and leaves it to the economic players to draw up the technical procedures and standards to specify in detail the ways and means of attaining them. Many countries have introduced requirements that new legislation and/or administrative regulations be subject to socio-economic analysis. In this respect there is a

  1. Development of flow injection analysis technique for uranium estimation

    International Nuclear Information System (INIS)

    Paranjape, A.H.; Pandit, S.S.; Shinde, S.S.; Ramanujam, A.; Dhumwad, R.K.

    1991-01-01

    Flow injection analysis is increasingly used as a process control analytical technique in many industries. It involves injection of the sample at a constant rate into a steady flowing stream of reagent and passing this mixture through a suitable detector. This paper describes the development of such a system for the analysis of uranium (VI) and (IV) and its gross gamma activity. It is amenable for on-line or automated off-line monitoring of uranium and its activity in process streams. The sample injection port is suitable for automated injection of radioactive samples. The performance of the system has been tested for the colorimetric response of U(VI) samples at 410 nm in the range of 35 to 360mg/ml in nitric acid medium using Metrohm 662 Photometer and a recorder as detector assembly. The precision of the method is found to be better than +/- 0.5%. This technique with certain modifications is used for the analysis of U(VI) in the range 0.1-3mg/ailq. by alcoholic thiocynate procedure within +/- 1.5% precision. Similarly the precision for the determination of U(IV) in the range 15-120 mg at 650 nm is found to be better than 5%. With NaI well-type detector in the flow line, the gross gamma counting of the solution under flow is found to be within a precision of +/- 5%. (author). 4 refs., 2 figs., 1 tab

  2. Burnout prediction using advance image analysis coal characterization techniques

    Energy Technology Data Exchange (ETDEWEB)

    Edward Lester; Dave Watts; Michael Cloke [University of Nottingham, Nottingham (United Kingdom). School of Chemical Environmental and Mining Engineering

    2003-07-01

    The link between petrographic composition and burnout has been investigated previously by the authors. However, these predictions were based on 'bulk' properties of the coal, including the proportion of each maceral or the reflectance of the macerals in the whole sample. Combustion studies relating burnout with microlithotype analysis, or similar, remain less common partly because the technique is more complex than maceral analysis. Despite this, it is likely that any burnout prediction based on petrographic characteristics will become more accurate if it includes information about the maceral associations and the size of each particle. Chars from 13 coals, 106-125 micron size fractions, were prepared using a Drop Tube Furnace (DTF) at 1300{degree}C and 200 millisecond and 1% Oxygen. These chars were then refired in the DTF at 1300{degree}C 5% oxygen and residence times of 200, 400 and 600 milliseconds. The progressive burnout of each char was compared with the characteristics of the initial coals. This paper presents an extension of previous studies in that it relates combustion behaviour to coals that have been characterized on a particle by particle basis using advanced image analysis techniques. 13 refs., 7 figs.

  3. Urine storage under refrigeration preserves the sample in chemical, cellularity and bacteriuria analysis of ACS

    Directory of Open Access Journals (Sweden)

    Karen Cristina Barcellos Ribeiro

    2013-12-01

    Full Text Available INTRODUCTION: The analysis of urine abnormal constituents and sediment (ACS comprises tests of great diagnostic and prognostic value in clinical practice. When the analysis of ACS cannot be performed within two hours after collection, the sample must be preserved in order to avoid pre-analytical interferences. Refrigeration is the most applied technique due to its cost effectiveness. Moreover, it presents fewer inconveniences when compared to chemical preservation. However, changes in ACS may also occur in samples under refrigeration. OBJECTIVE: To analyze the influence of refrigeration at 2 to 8ºC on the storage of urine samples within 24 hours. MATERIAL AND METHOD: A total of 80 urine samples were selected from patients admitted at Universidade Federal de Juiz de Fora (UFJF university hospital, which were tested for ACS at room temperature and stored under refrigeration for 6, 12 and 24 hours. RESULTS: The results showed that refrigeration proved to be effective when compared to samples kept at room temperature, inasmuch as the physical, chemical, microbial and cellularity features were preserved. Nevertheless, crystalluria was present after a 6- hour storage period. CONCLUSION: The tests revealed that cooling preserved cellularity and chemical characteristics of urine samples for up to 12 hours. Nonetheless, the precipitation of crystals was evident in this storage method. Thus, the possible consequences of storing urine samples for ACS test under these conditions should be included in the analysis report.

  4. Analysis of Cultural Heritage by Accelerator Techniques and Analytical Imaging

    Science.gov (United States)

    Ide-Ektessabi, Ari; Toque, Jay Arre; Murayama, Yusuke

    2011-12-01

    In this paper we present the result of experimental investigation using two very important accelerator techniques: (1) synchrotron radiation XRF and XAFS; and (2) accelerator mass spectrometry and multispectral analytical imaging for the investigation of cultural heritage. We also want to introduce a complementary approach to the investigation of artworks which is noninvasive and nondestructive that can be applied in situ. Four major projects will be discussed to illustrate the potential applications of these accelerator and analytical imaging techniques: (1) investigation of Mongolian Textile (Genghis Khan and Kublai Khan Period) using XRF, AMS and electron microscopy; (2) XRF studies of pigments collected from Korean Buddhist paintings; (3) creating a database of elemental composition and spectral reflectance of more than 1000 Japanese pigments which have been used for traditional Japanese paintings; and (4) visible light-near infrared spectroscopy and multispectral imaging of degraded malachite and azurite. The XRF measurements of the Japanese and Korean pigments could be used to complement the results of pigment identification by analytical imaging through spectral reflectance reconstruction. On the other hand, analysis of the Mongolian textiles revealed that they were produced between 12th and 13th century. Elemental analysis of the samples showed that they contained traces of gold, copper, iron and titanium. Based on the age and trace elements in the samples, it was concluded that the textiles were produced during the height of power of the Mongol empire, which makes them a valuable cultural heritage. Finally, the analysis of the degraded and discolored malachite and azurite demonstrates how multispectral analytical imaging could be used to complement the results of high energy-based techniques.

  5. Symbolic manipulation techniques for vibration analysis of laminated elliptic plates

    Science.gov (United States)

    Andersen, C. M.; Noor, A. K.

    1977-01-01

    A computational scheme is presented for the free vibration analysis of laminated composite elliptic plates. The scheme is based on Hamilton's principle, the Rayleigh-Ritz technique and symmetry considerations and is implemented with the aid of the MACSYMA symbolic manipulation system. The MACYSMA system, through differentiation, integration, and simplification of analytic expressions, produces highly-efficient FORTRAN code for the evaluation of the stiffness and mass coefficients. Multiple use is made of this code to obtain not only the frequencies and mode shapes of the plate, but also the derivatives of the frequencies with respect to various material and geometric parameters.

  6. Data Analysis Techniques for a Lunar Surface Navigation System Testbed

    Science.gov (United States)

    Chelmins, David; Sands, O. Scott; Swank, Aaron

    2011-01-01

    NASA is interested in finding new methods of surface navigation to allow astronauts to navigate on the lunar surface. In support of the Vision for Space Exploration, the NASA Glenn Research Center developed the Lunar Extra-Vehicular Activity Crewmember Location Determination System and performed testing at the Desert Research and Technology Studies event in 2009. A significant amount of sensor data was recorded during nine tests performed with six test subjects. This paper provides the procedure, formulas, and techniques for data analysis, as well as commentary on applications.

  7. Nonactivation interaction techniques in the analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.

    1986-01-01

    Nonactivation interaction analytical methods are based on the interaction processes of nuclear and X-ray radiation with a sample, leading to their absorption and backscattering, to the ionization of gases or excitation of fluorescent X-ray by radiation, but not to the activation of determined elements. From the point of view of environmental analysis, the most useful nonactivation interaction techniques are X-ray fluorescence by photon or charged particle excitation, ionization of gases by nuclear radiation, elastic scattering of charged particles and backscattering of beta radiation. The significant advantage of these methods is that they are nondestructive. (author)

  8. From Technique of Tattooing to Biokinetics and Toxicology of Injected Tattoo Ink Particles and Chemicals

    DEFF Research Database (Denmark)

    Serup, Jørgen

    2017-01-01

    by banning potentially critical chemicals hitherto has been unsuccessful due to lacking documentation of clinical and epidemiological relevance and because the tattoo industry is already internationally established, free, and in the ownership of the people. Doctors treating patients with tattoo complications...

  9. Chemical or electrochemical techniques, followed by ion exchange, for recycle of textile dye wastewater.

    Science.gov (United States)

    Raghu, S; Ahmed Basha, C

    2007-10-22

    This paper examines the use of chemical or electrocoagulation treatment process followed by ion-exchange process of the textile dye effluent. The dye effluent was treated using polymeric coagulant (cationic dye-fixing agent) or electrocoagulation (iron and aluminum electrode) process under various conditions such as various current densities and effect of pH. Efficiencies of COD reduction, colour removal and power consumption were studied for each process. The chemical or electrochemical treatment are indented primarily to remove colour and COD of wastewater while ion exchange is used to further improve the removal efficiency of the colour, COD, Fe concentration, conductivity, alkalinity and total dissolved solids (TDS). From the results chemical coagulation, maximum COD reduction of about 81.3% was obtained at 300 mg/l of coagulant whereas in electrocoagulation process, maximum COD removal of about 92.31% (0.25 A/dm2) was achieved with energy consumption of about 19.29 k Wh/kg of COD and 80% (1A/dm(2)) COD removal was obtained with energy consumption of about 130.095 k Wh/kg of COD at iron and aluminum electrodes, respectively. All the experimental results, throughout the present study, have indicated that chemical or electrocoagulation treatment followed by ion-exchange methods were very effective and were capable of elevating quality of the treated wastewater effluent to the reuse standard of the textile industry.

  10. Forensic analysis methodology for thermal and chemical characterization of homemade explosives

    International Nuclear Information System (INIS)

    Nazarian, Ashot; Presser, Cary

    2014-01-01

    Highlights: • Identification of homemade explosives (HME) is critical for determining the origin of explosive precursor materials. • A novel laser-heating technique was used to obtain the thermal/chemical signatures of HME precursor materials. • Liquid-fuel saturation of the pores of a solid porous oxidizer affected the total specific heat release. • Material thermal signatures were dependent on sample mass and heating rate. • This laser-heating technique can be a useful diagnostic tool for characterizing the thermochemical behavior of HMEs. - Abstract: Forensic identification of homemade explosives is critical for determining the origin of the explosive materials and precursors, and formulation procedures. Normally, the forensic examination of the pre- and post-blast physical evidence lacks specificity for homemade-explosive identification. The focus of this investigation was to use a novel measurement technique, referred to as the laser-driven thermal reactor, to obtain the thermal/chemical signatures of homemade-explosive precursor materials. Specifically, nitromethane and ammonium nitrate were studied under a variety of operating conditions and protocols. Results indicated that liquid-fuel saturation of the internal pores of a solid particle oxidizer appear to be a limiting parameter for the total specific heat release during exothermic processes. Results also indicated that the thermal signatures of these materials are dependent on sample mass and heating rate, for which this dependency may not be detectable by other commercially available thermal analysis techniques. This study has demonstrated that the laser-driven thermal reactor can be a useful diagnostic tool for characterizing the thermal and chemical behavior of trace amounts of homemade-explosive materials

  11. Prompt Gamma Activation Analysis (PGAA): Technique of choice for nondestructive bulk analysis of returned comet samples

    International Nuclear Information System (INIS)

    Lindstrom, D.J.; Lindstrom, R.M.

    1989-01-01

    Prompt gamma activation analysis (PGAA) is a well-developed analytical technique. The technique involves irradiation of samples in an external neutron beam from a nuclear reactor, with simultaneous counting of gamma rays produced in the sample by neutron capture. Capture of neutrons leads to excited nuclei which decay immediately with the emission of energetic gamma rays to the ground state. PGAA has several advantages over other techniques for the analysis of cometary materials: (1) It is nondestructive; (2) It can be used to determine abundances of a wide variety of elements, including most major and minor elements (Na, Mg, Al, Si, P, K, Ca, Ti, Cr, Mn, Fe, Co, Ni), volatiles (H, C, N, F, Cl, S), and some trace elements (those with high neutron capture cross sections, including B, Cd, Nd, Sm, and Gd); and (3) It is a true bulk analysis technique. Recent developments should improve the technique's sensitivity and accuracy considerably

  12. Uranium complexes with macrosyclic polyethers. Synthesis and structural chemical analysis

    International Nuclear Information System (INIS)

    Elbasyouny, A.

    1983-01-01

    This dissertation reports about studies on the chemical coordination behaviour of uranium of oxidation stages IV and VI with regard to twelve different macrocyclic ligands. For the preparation of the complexes, for every system a different method has been developed. The elementary analysis of the various complexes including the uranium had been done by X-ray fluorescence analysis, and the structural characterization proceeded via vibrational, uv-vis and emission spectroscopy as well as 1 H-NMR and 13 C-spin-lattice relaxation time studies. Conformational analysis of the polyethers used allowed the structural changes in the complexes to be observed. The structural analysis of the hydrous uranium VI crown ether complexes yielded information of characteristic features of these types of complexes. The first coordination sphere of the uranyl ion with covalently bonded anion remains unchanged. As to the water content, there is a certain range. Depending upon the solvent used, the complexes have two or four H 2 O molecules per formula unit. (orig./EF) [de

  13. Evaluation and Optimization Study on a Hybrid EOR Technique Named as Chemical-Alternating-Foam Floods

    Directory of Open Access Journals (Sweden)

    Xu Xingguang

    2017-01-01

    Full Text Available This work presents a novel Enhanced Oil Recovery (EOR method called Chemical-Alternating-Foam (CAF floods in order to overcome the drawbacks of the conventional foam flooding such as insufficient amount of in-situ foams, severe foam collapse and surfactant retention. The first part of this research focused on the comparison of conventional foam floods and CAF floods both of which had the same amount of gas and chemicals. It showed that: (1 CAF floods possessed the much greater Residual Resistance Factor (RRF at elevated temperature; (2 the accumulative oil recovery of the CAF floods was 10%-15% higher than that of the conventional foam flooding. After 1.8 Pore Volume (PV injection, the oil recovery reached the plateau for both methods; (3 CAF floods yielded the most amount of incremental oil at the 98% water cut (water content in the effluent, while the continuous foam floods achieved the best performance at 60% water cut. The second part of this work determined the optimal foam quality (gas/liquid ratio or the volume percent gas within foam, chemical/foam slug size ratio, cycle number and injection sequence for the CAF floods. It was found that the CAF was endowed with the peak performance if the foam quality, chemical/foam slug size ratio, cycle number was fixed at 80%, 1:1 and 3 respectively with the chemical slug being introduced ahead of the foam slug. Through systematic and thorough research, the proposed hybrid process has been approved to be a viable and effective method significantly strengthening the conventional foam flooding.

  14. Analysis of nifedipine content in transdermal drug delivery system using non-destructive visible spectrophotometry technique

    International Nuclear Information System (INIS)

    Normaizira Hamidi; Normaizira Hamidi; Normaizira Hamidi; Mohd Nasir Taib; Mohd Nasir Taib; Wui, Wong Tin; Wui, Wong Tin

    2008-01-01

    The applicability of visible spectrophotometry technique as a tool to determine the drug content of polymeric film for use as a transdermal drug delivery system was investigated. Hydroxypropylmethycellulose (HPMC) was selected as the matrix polymer and nifedipine as the model drug. Blank and nifedipine-loaded HPMC films were prepared using the solvent evaporation method. The absorbance spectra of these films under the visible wavelengths between 400 and 800 nm were assessed and compared against the drug content values obtained by means of the conventional destructive UV- spectrophotometry technique. The latter required the use of a solvent system which contained methanol, a harmful organic component in pharmaceutical applications. The results indicated that the absorbance values, attributed to nifedipine, at the wavelengths of 545, 585, 638 and 755nm were significantly correlated to the drug content values obtained using the chemical assay method (Pearson correlation value: r = 0.990 and p < 0.01). The visible spectrophotometry technique is potentially suitable for use to determine the nifedipine content of films owing to its nature of characterization of transdermal drug delivery system which does not require sample destruction during the process of measurement. The samples are recoverable from test and analysis of the entire batch of samples is possible without the need of solvents and chemical reagents. (author)

  15. Methods for magnetic resonance analysis using magic angle technique

    Science.gov (United States)

    Hu, Jian Zhi [Richland, WA; Wind, Robert A [Kennewick, WA; Minard, Kevin R [Kennewick, WA; Majors, Paul D [Kennewick, WA

    2011-11-22

    Methods of performing a magnetic resonance analysis of a biological object are disclosed that include placing the object in a main magnetic field (that has a static field direction) and in a radio frequency field; rotating the object at a frequency of less than about 100 Hz around an axis positioned at an angle of about 54.degree.44' relative to the main magnetic static field direction; pulsing the radio frequency to provide a sequence that includes a phase-corrected magic angle turning pulse segment; and collecting data generated by the pulsed radio frequency. In particular embodiments the method includes pulsing the radio frequency to provide at least two of a spatially selective read pulse, a spatially selective phase pulse, and a spatially selective storage pulse. Further disclosed methods provide pulse sequences that provide extended imaging capabilities, such as chemical shift imaging or multiple-voxel data acquisition.

  16. Techniques for the analysis of pentacyclic triterpenoids in medicinal plants.

    Science.gov (United States)

    Xu, Congcong; Wang, Bing; Pu, Yiqiong; Tao, Jiansheng; Zhang, Tong

    2018-01-01

    Triterpenes are a major class of chemical compounds found in natural plants and can be categorized into acyclic triterpenoids, monocyclic triterpenoids, tricyclic triterpenoids, tetracyclic triterpenoids, and pentacyclic triterpenoids. Among them, pentacyclic triterpenoids have gained more extensive attention due to their biological activities, including anti-inflammation, antibacterial, antioxidation, antitumor, anti-HIV, hepatoprotection, and immunological adjuvant properties. In this review, we summarize the extraction and analytical methods for pentacyclic triterpenoids, where more than 56 triterpenes from 49 kinds of plants were involved. The analysis methods include gas chromatography, liquid chromatography, capillary electrophoresis, thin-layer chromatography, supercritical fluid chromatography, NMR spectroscopy, and X-ray spectroscopy. This review provides valuable reference for the determination of pentacyclic triterpenoids in medicinal plants. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. DEVELOPMENT OF TECHNIQUES FOR QUANTITATIVE ANALYSIS OF LIME FLOWERS

    Directory of Open Access Journals (Sweden)

    Demyanenko DV

    2016-03-01

    Full Text Available Introduction. The article is devoted to the development of techniques for quantitative analysis of lime flower in order to make amendments to existing pharmacopoeian monographs for this herbal drug. Lime inflorescences contain lipophilic biologically active substances (BAS causing notable antimicrobial and anti-inflammatory effects and also more polar phenolic compounds with antiulcer activity. Considering this, it’s necessary to regulate all these groups of BAS quantitatively. Materials and methods. For this study six batches of lime flowers harvested in 2008-2009 yrs. in Kharkiv, Rivno and Zhitomir regions were used as crude herbal drug. Loss on drying was determined by routine pharmacopoeian procedures. Total content of lipophilic substances was determined gravimetrically after Soxhlet extraction of samples 1, 5, 7 and 10 g in weight with methylene chloride, considering that by its extracting ability this solvent is close to liquefied difluorochloromethane (freon R22 used by us for obtaining of lipophilic complexes. The duration of complete analytical extraction was determined by infusion of six 10 g assays of lime flowers during 1, 2, 3, 4, 5, 6 hours, then quantity of lipophilic extractives was revealed gravimetrically. Quantity of essential oil in lime flowers was evaluated under the procedure of ЕР7, 2.8.12. Weight of the herbal drug sample was 200 g, distillation rate – 2,5- 3,5 ml/min, volume of distillation liquid (water – 500 ml, volume of xylene in the graduated tube – 0,50 ml. Total flavonoid content recalculated to quercetin was determined after hydrolysis with acidified acetone, withdrawing of flavonoid aglycones with ethylacetate and by further spectrophotometry of their complexes with aluminium chloride. All quantitative determinations were replicated five times for each assay. All chemicals and reagents were of analytical grade. Results and discussion. It was found that adequate accuracy of the analysis of lipophilic

  18. Macro elemental analysis of food samples by nuclear analytical technique

    Science.gov (United States)

    Syahfitri, W. Y. N.; Kurniawati, S.; Adventini, N.; Damastuti, E.; Lestiani, D. D.

    2017-06-01

    Energy-dispersive X-ray fluorescence (EDXRF) spectrometry is a non-destructive, rapid, multi elemental, accurate, and environment friendly analysis compared with other detection methods. Thus, EDXRF spectrometry is applicable for food inspection. The macro elements calcium and potassium constitute important nutrients required by the human body for optimal physiological functions. Therefore, the determination of Ca and K content in various foods needs to be done. The aim of this work is to demonstrate the applicability of EDXRF for food analysis. The analytical performance of non-destructive EDXRF was compared with other analytical techniques; neutron activation analysis and atomic absorption spectrometry. Comparison of methods performed as cross checking results of the analysis and to overcome the limitations of the three methods. Analysis results showed that Ca found in food using EDXRF and AAS were not significantly different with p-value 0.9687, whereas p-value of K between EDXRF and NAA is 0.6575. The correlation between those results was also examined. The Pearson correlations for Ca and K were 0.9871 and 0.9558, respectively. Method validation using SRM NIST 1548a Typical Diet was also applied. The results showed good agreement between methods; therefore EDXRF method can be used as an alternative method for the determination of Ca and K in food samples.

  19. Measuring caloric response: comparison of different analysis techniques.

    Science.gov (United States)

    Mallinson, A I; Longridge, N S; Pace-Asciak, P; Ngo, R

    2010-01-01

    Electronystagmography (ENG) testing has been supplanted by newer techniques of measuring eye movement with infrared cameras (VNG). Most techniques of quantifying caloric induced nystagmus measure the slow phase velocity in some manner. Although our analysis is carried out by very experienced assessors, some systems have computer algorithms that have been "taught" to locate and quantify maximum responses. We wondered what differences in measurement might show up when measuring calorics using different techniques and systems, the relevance of this being that if there was a change in slow phase velocity between ENG and VNG testing when measuring caloric response, then normative data would have to be changed. There are also some subjective but important aspects of ENG interpretation which comment on the nature of the response (e.g. responses which might be "sporadic" or "scant"). Our experiment compared caloric responses in 100 patients analyzed four different ways. Each caloric was analyzed by our old ENG system, our new VNG system, an inexperienced assessor and the computer algorithm, and data was compared. All four systems made similar measurements but our inexperienced assessor failed to recognize responses as sporadic or scant, and we feel this is a limitation to be kept in mind in the rural setting, as it is an important aspect of assessment in complex patients. Assessment of complex VNGs should be left to an experienced assessor.

  20. Mechanisms of subsidence for induced damage and techniques for analysis

    International Nuclear Information System (INIS)

    Drumm, E.C.; Bennett, R.M.; Kane, W.F.

    1988-01-01

    Structural damage due to mining induced subsidence is a function of the nature of the structure and its position on the subsidence profile. A point on the profile may be in the tensile zone, the compressive zone, or the no-deformation zone at the bottom of the profile. Damage to structures in the tension zone is primarily due to a reduction of support during vertical displacement of the ground surface, and to shear stresses between the soil and structure resulting from horizontal displacements. The damage mechanisms due to tension can be investigated effectively using a two-dimensional plane stress analysis. Structures in the compression zone are subjected to positive moments in the footing and large compressive horizontal stresses in the foundation walls. A plane strain analysis of the foundation wall is utilized to examine compression zone damage mechanisms. The structural aspects affecting each mechanism are identified and potential mitigation techniques are summarized