WorldWideScience

Sample records for chasing computed tomography

  1. Computed Tomography (CT) -- Sinuses

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Videos related to Computed Tomography (CT) - Head About this Site RadiologyInfo.org is produced by: Please note ... you can search the ACR-accredited facilities database . This website does not provide cost information. The costs ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Images related to Computed Tomography (CT) - Sinuses About this Site RadiologyInfo.org is produced by: Please note ... you can search the ACR-accredited facilities database . This website does not provide cost information. The costs ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  8. Neutron Computed Tomography

    International Nuclear Information System (INIS)

    Computed tomography is a non-destructive testing method which can visualize cross-section of materials based on their nuclear characteristics. In the previous work, X-ray was used as its radiation media. The aim of this experiment was to improve the computed tomography technique using neutron beam. For reconstructing the cross-section image of materials, a filtered back projection was used. Result indicated that a minimum hole shown was 3 mm in diameter using a black and white presentation. While using eight colour levels, a hole of 2 mm in diameter could be seen clearly. It is expected that neutron computed tomography can improve the results of non-destructive testing. (author). 5 refs., 6 figs

  9. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret;

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  13. Multiplanner spine computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Chung, H. K.; Jeon, H. J.; Hong, K. C.; Chung, K. B.; Suh, W. H. [Korea University College of Medicine, Seoul (Korea, Republic of)

    1983-06-15

    The computed tomography is useful in evaluation of bony structures and adjacent soft tissues of the spine. Recently, the multiplanar spine CT scan is highly superior than usual axial scan, because of easily demonstrable longitudinal dimension, level of spine and spinal canal. We evaluated 62 cases of spine CT, whom complains of spinal symptoms, from July, 1982 to January, 1983. The results were as follows: 1. The sex distribution of cases were 45 male and 17 female, ages were from 15 years to 76 years, and sites were 15 cervical spine, 7 thoracic spine, 42 lumbar spine and 21 sacral spine. 2. Sixty two cases of the CT diagnosis were reviewed and shows 19 cases of herniated intervertebral disc, 7 cases of spine fracture, 5 cases of degenerative disease, 4 cases of metastatic cancer, 2 cases of posterior longitudinal ligament ossification, 1 case of cord injury and 24 cases of normal. 3. The CT findings of herniated intervertebral disc were protruding disc, obliteration of anterior epidural fat, with or without indentation of dural sac and calcification within posterior disc margin. In cases of trauma, the multiplanar spine CT scan detects more specific extension of the fracture sites, and it is able to demonstrate relationship between fracture fragment and spinal cord, therefore operability can be decided. In case of posterior longitudinal ligament ossification, it is easy to demonstrate linear high density along posterior margin of vertebral bodies on sagittal reconstruction scan. 4. The computed tomography is diagnostic in detection of spinal disease. However, multiplanar spine CT is more diagnostic than axial computed tomography such as detecting the longitudinal dimension and demonstration of spinal canal.

  14. Computed tomography device

    International Nuclear Information System (INIS)

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  15. Stored Luminescence Computed Tomography

    CERN Document Server

    Cong, Wenxiang; Wang, Ge

    2013-01-01

    The phosphor nanoparticles made of doped semiconductors, pre-excited by well-collimated X-ray radiation, were recently reported for their light emission upon NIR light stimulation. The characteristics of X-ray energy storage and NIR stimulated emission is highly desirable to design targeting probes and improve molecular and cellular imaging. Here we propose stored luminescence computed tomography (SLCT), perform realistic numerical simulation, and demonstrate a much-improved spatial resolution in a preclinical research context. The future opportunities are also discussed along this direction.

  16. Multislice computed tomography coronary angiography

    OpenAIRE

    Cademartiri, Filippo

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield of EMI Laboratories, England, and independently by South Mrican born physicist Allan Cormack of Tufts University, Massachusetts.1 • 2 Hounsfield was later awarded the Nobel Peace Prize and honoured with K...

  17. Spinal computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sartor, K.

    1980-10-01

    Computed tomography (CT) of the spine and spinal cord is gaining more and more importance as a valuable investigative method in neuroradiology. Performed as a noninvasive procedure, with or without intravenous contrast enhancement, it can be used to diagnose paravertebral soft tissue lesions, constrictive lesions of the bony spinal canal, structure changes of the vertebral column or of individual vertebrae, vascular intraspinal lesions, and intraspinal tumors with abnormally high or abnormally low attenuation values. Performed as an invasive procedure, after intrathecal introduction of metrizamide, spinal CT can in selected cases be used in conjunction with conventional metrizamide myelography as an additional procedure (secondary CT-myelography) or even as initial procedure ( primary CT-myelography), taking advantage of its unique properties, namely to provide a transverse axial image of the spine and related soft tissue structures and to detect even small differences in density. Further improvement of spinal CT, particularly the routine non-invasive demonstration of the intraspinal soft tissues, is to be expected.

  18. Computed tomography apparatus

    International Nuclear Information System (INIS)

    In fan-beam computed tomography apparatus, timing reference pulses, normally occurring at intervals t, for data transfer and reset of approx. 500 integrators in the signal path from the detector array, are generated from the scan displacement, e.g. using a graticule and optical sensor to relate the measurement paths geometrically to the body section. Sometimes, a slow scan rate is required to provide a time-averaged density image, e.g. for planning irradiation therapy, and then the sensed impulses will occur at extended intervals and can cause integrator overload. An improvement is described which provides a pulse generator which responds to a reduced scan rate by generating a succession of further transfer and reset pulses at intervals approximately equal to t starting a time t after each timing reference pulse. Then, using an adding device and RAM, all the transferred signals integrated in the interval t' between two successive slow scan reference pulses are accumulated in order to form a corresponding measurement signal. (author)

  19. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von;

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature th...

  20. Computed tomography of the prostate.

    Science.gov (United States)

    Van Engelshoven, J M; Kreel, L

    1979-02-01

    The conventional anatomy of the prostate is reviewed and the computed tomography (CT) anatomy described and illustrated. The results of 55 "normal" cases were analyzed for size and relationship to the symphysis pubis, retropubic space, and bladder, as shown on CT sections correlating the features with age and possible urinary symptoms. Attention is also drawn to the differences between phleboliths and prostatic calcification. Computed tomography is an effective method of demonstrating the prostate and surrounding structures and of assessing prostatic enlargement.

  1. What is Computed Tomography?

    Science.gov (United States)

    ... word "tomography" is from the Greek word "tomos" meaning "slice" or "section" and "graphe" meaning "drawing." A CT imaging system produces cross-sectional ... The patient may receive an injection of a "contrast material" to facilitate visualization of vascular structure. Detectors ...

  2. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  5. Computer tomography in acute pyelonephritis

    Energy Technology Data Exchange (ETDEWEB)

    Triller, J.; Scheidegger, J.; Terrier, F.

    1983-07-01

    Computer tomography of the kidneys was performed on 30 patients with acute renal infections (acute suppurative pyelonephritis, acute renal abscess, infected cyst, pyelonephrosis, calculus perforation, retroperitoneal abscess). Computer tomography provided more accurate information concerning the extent of the renal and extra-renal inflammatory process than did the urogram or sonogram. This may significantly affect the choice of treatment, particularly concerning the use of drugs or of surgery. Angiography and retrograde pyelography may be used in selected cases, especially where there is a suspicion of acute bacterial nephritis, renal vein thrombosis or ureteric obstruction.

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... ray beam follows a spiral path. A special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a ... by computer software, the result is a very detailed multidimensional ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... ray beam follows a spiral path. A special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a ... by computer software, the result is a very detailed multidimensional ...

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... look like? The CT scanner is typically a large, box-like machine with a hole, or short ... spiral path. A special computer program processes this large volume of data to create two-dimensional cross- ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... look like? The CT scanner is typically a large, box-like machine with a hole, or short ... spiral path. A special computer program processes this large volume of data to create two-dimensional cross- ...

  14. Computed tomography:the details.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin Walter

    2007-07-01

    Computed Tomography (CT) is a well established technique, particularly in medical imaging, but also applied in Synthetic Aperture Radar (SAR) imaging. Basic CT imaging via back-projection is treated in many texts, but often with insufficient detail to appreciate subtleties such as the role of non-uniform sampling densities. Herein are given some details often neglected in many texts.

  15. Facility for positron computed tomography

    International Nuclear Information System (INIS)

    The positron computed tomography facility has got scintillator detector rings simultaneously recording more than one tomogrphic image of different cross-sections of the patient. The detectors in neighboring rings are staggered and can be rotated with respect to each other in order to increase the count rate without loss of efficiency. (DG)

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... gantry. The computer workstation that processes the imaging information is located ... in detector technology allow nearly all CT scanners to obtain multiple ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... gantry. The computer workstation that processes the imaging information is located ... in detector technology allow nearly all CT scanners to obtain multiple ...

  18. Pediatric cranial computed tomography

    International Nuclear Information System (INIS)

    The introduction of CT in the investigation of intercranial pathology has revolutionized the approach to clinical neurological and neurosurgical practice. This book applies the advances of cranial CT to the pediatric patient. The test is divided into two sections. The first portion describes the practical methodology, anatomy and normal and abnormal CT scan appearance, including high or low density lesions, cystic lesions and ventricular or subarachnoid space dilation. The characteristic scans for various neurological diseases are presented and discussed. The author has given special attention to the CT diagnosis of congenital malformations and cerebral neoplasms. Partial Contents: Normal Computed Tomographic Anatomy/ High Density Lesions/Low Density Lesions/Cystic Lesions; Supratentorial/Cystic Lesions; Infratentorial/Increased Head Circumference/Increased Ventricular Size/Small Ventricular Size/Cranial Lesions/Spinal Lesions/CT Cisternography/Part II CT in Neonates/Congenital Craniocerebral Malformations/Hydrocephalus/Craniosynostosis/Head Trauma/Cerebrovascular Lesions/Intracranial Lesions/Seizure Disorders/Intracranial and Other Chronic Neurological Disorders

  19. Computed tomography of gynecologic diseases

    International Nuclear Information System (INIS)

    Although computed tomography (CT) provides superb images of all areas of the body, sonography, because of its lack of ionizing radiation and its real-time and multiplanar capacities, has become the preferred initial method of evaluating the female pelvis. This has resulted in a relative paucity of information in the literature concerning CT features of benign pelvic disorders in particular and prompted the authors to review our experience with third-generation CT scanning of the uterus and ovaries

  20. Cranial computed tomography in paediatrics

    International Nuclear Information System (INIS)

    This paper deals mainly with methodical aspects (such as sedation, intravenous and intrathecal application of contrast media) and with common difficulties in interpretation of computed tomography images. The indications for cranial CT are discussed in respect probable therapeutic consequences and expected diagnostic yield. In view of the author CT is, as a rule, not required in assessing chronic headache, generalised epileptic convulsions, non-specific mental retardation and cerebral palsy. (Author)

  1. Cranial computed tomography in pediatrics

    Energy Technology Data Exchange (ETDEWEB)

    Boltshauser, E. (Zuerich Univ. (Switzerland). Kinderklinik)

    1984-01-01

    This paper deals mainly with methodical aspects (such as sedation, intravenous and intrathecal application of contrast media) and with common difficulties in interpretation of computed tomography images. The indications for cranial CT are discussed in respect to probable therapeutic consequences and expected diagnostic yield. In the view of the author CT is, as a rule, not required in assessing chronic headache, generalised epileptic convulsions, non-specific mental retardation and cerebral palsy.

  2. Single Photon Emission Computed Tomography (SPECT)

    Science.gov (United States)

    ... Tools & Resources Stroke More Single Photon Emission Computed Tomography (SPECT) Updated:Sep 11,2015 What is a ... Heart Attack Myocardial Perfusion Imaging (MPI) Positron Emission Tomography (PET) Radionuclide Ventriculography, Radionuclide Angiography, MUGA Scan Heart ...

  3. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Blood Pressure Tools & Resources Stroke More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 3,2015 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  4. The history of computed tomography

    International Nuclear Information System (INIS)

    New scientific discoveries are often made by the synthetising of other discoveries. Computed tomography is such an example. The three necessary elements were: 1/ the fact that certain simple crystals scintillate when exposed to X-rays, 2/ the advent of electronics and 3/ that of computers. The fact that X-rays cause crystals to scintillate was learnt very shortly after Roentgen's discovery, electronics and computers coming very much later. To put all these together and apply them to diagnostic radiology, and at the same time dismiss the concept so firmly ingrained in everyone's mind that an X-ray picture must be produced on photographic film, required a genius. (orig./VJ)

  5. Industrial applications of computed tomography

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carmignato, S.; Kruth, J. -P.;

    2014-01-01

    The number of industrial applications of Computed Tomography(CT) is large and rapidly increasing. After a brief market overview, the paper gives a survey of state of the art and upcoming CT technologies, covering types of CT systems, scanning capabilities, and technological advances. The paper...... contains a survey of application examples from the manufacturing industry as well as from other industries, e.g., electrical and electronic devices, inhomogeneous materials, and from the food industry. Challenges as well as major national and international coordinated activities in the field of industrial...

  6. Facility for positron computed tomography

    International Nuclear Information System (INIS)

    For positron computed tomography two or more rings of scintillation detectors are used by which three or more sections of the object may be determined at a time. The rings are placed in parallel planes having got some distance from each other, axially movable collimator rings being provided for. Each collimator can be moved towards the opposite collimator and towards a central collimator which also is ring-shaped and is placed between the rows of detectors. The external and internal collimator are used for data selection and image-forming. (DG)

  7. Computed tomography of the spine

    International Nuclear Information System (INIS)

    Until the advent of Computed Tomography (CT), axial studies of the spine were limited in the main to gross bony anatomy and to conventional transaxial tomography (TAT). Others studied the upper cervical cord in transverse section during gas myelography and encephalography. The potential role of CT in the evaluation of spinal anatomy and disease was recognized, however, at an early stage in the development of the general purpose CT scanner. CT is not organ specific and therefore provides a uniformly thin (1.5-13 mm) axial section displaying detailed spinal topographical anatomy against a background of paravertebral muscles, vascular structures and body cavity organs. The relationships of the apophyseal joints to the spinal canal and intervertebral foramina are particularly well displayed. The study of neural tissue and pathology within the spinal canal is facilitated by the use of a non-ionic water-soluble contrast medium (viz. metrizamide) in the subarachnoid spaces. The high sensitivity of CT to very small changes in X-ray attenuation permits studies to be continued over several hours. The digital derivation of the sequential CT transaxial sections enables not only interrogation of data and quantitative studies to be made but also makes possible computer-generated reconstructions in other planes

  8. Adaptive Computed Tomography Imaging Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The present proposal describes the development of an adaptive Computed Tomography Imaging Spectrometer (CTIS), or "Snapshot" spectrometer which can...

  9. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and comp

  10. Chasing Noise

    OpenAIRE

    Mendel, Brock; Shleifer, Andrei

    2012-01-01

    We present a simple model in which rational but uninformed traders occasionally chase noise as if it were information, thereby amplifying sentiment shocks and moving prices away from fundamental values. We fill a theoretical gap in the literature by showing conditions under which noise traders can have an impact on market equilibrium disproportionate to their size in the market. The model offers a partial explanation for the surprisingly low market price of financial risk in the Spring of 2007.

  11. Computed tomography in sport injuries

    International Nuclear Information System (INIS)

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability. (orig.)

  12. COMPUTED TOMOGRAPHY PERITONEAL CANCER INDEX

    Directory of Open Access Journals (Sweden)

    Tiutiuca RC

    2006-07-01

    Full Text Available Peritoneal surface malignancy results from seeding of gastrointestinal cancer or abdomino-pelvic sarcoma, or it can occur as a primary disease, such as peritoneal mesothelioma. In the past, this clinical situation was treated only with palliative intent. Actual treatment options for surgical management uses cytoreductive surgery which combines peritonectomy and visceral resection in an effort to remove all visible cancer within the abdomen and pelvis. Then the peritoneal cavity is flooded with chemotherapy solution. To select patients for this agressive approach quantitative prognostic indicators for carcinomatosis must be evaluated. The peritoneal cancer index (PCI is a synthesis of the distribution of tumor and a lesion size score. In such conditions abdominal medium contrast computed-tomography it is very helpful in identification of neoplasic implants.

  13. [Computer tomography of sports injuries].

    Science.gov (United States)

    Reiser, M; Rupp, N

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  14. Computed tomography in sport injuries

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M.; Rupp, N.

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  15. Diagnostic usefulness of computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, K.; Tsugawa, R.; Yamakawa, Y. (Kanazawa Medical Univ., Uchinada, Ishikawa (Japan))

    1981-07-01

    Computed tomography (CT) has been used as a diagnostic technique in various urological diseases. Here demonstrated is a case of ureteral incontinence with double renal pelvis whose upper one has ectopic ureteral orifice. Also a case of ureteral stricture in transplanted kidney and three cases of uric acid calculi are demonstrated. CT provides accurate information in each diagnostic procedure. The use of CT in the diagnosis of urinary stones is estimated. CT number of 75 stones with single component shows specific distribution in relation to the component; ex. calcium stones: 900 - 1000, cystine: 700 - 800, struvite: 600 - 700, uric acid: 400 - 500. Structure and component of the stone is easily demonstrated by CT, especially about nonopaque calculi, whose image is positively displayed only by CT.

  16. Computed tomography in hepatic trauma

    International Nuclear Information System (INIS)

    Twenty-five patients with hepatic injury from blunt upper abdominal trauma were examined by computed tomography (CT). The spectrum of CT findings was recorded, and the size of the hepatic laceration and the associated hemoperitoneum were correlated with the mode of therapy used in each case (operative vs nonoperative). While the need for surgery correlated roughly with the size of the hepatic laceration, the size of the associated hemoperitoneum was an important modifying factor. Fifteen patients with hepatic lacerations but little or no hemoperitoneum were managed nonoperatively. CT seems to have significant advantages over hepatic scintigraphy, angiography, and diagnostic peritoneal lavage. By combining inforamtion on the clinical state of the patient and CT findings, therapy of hepatic injury can be individualized and the incidence of nontherapeutic laparotomies decreased

  17. Computed tomography of cryogenic cells

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Gerd; Anderson, E.; Vogt, S.; Knochel, C.; Weiss, D.; LeGros, M.; Larabell, C.

    2001-08-30

    Due to the short wavelengths of X-rays and low numerical aperture of the Fresnel zone plates used as X-ray objectives, the depth of field is several microns. Within the focal depth, imaging a thick specimen is to a good approximation equivalent to projecting the specimen absorption. Therefore, computed tomography based on a tilt series of X-ray microscopic images can be used to reconstruct the local linear absorption coefficient and image the three-dimensional specimen structure. To preserve the structural integrity of biological objects during image acquisition, microscopy is performed at cryogenic temperatures. Tomography based on X-ray microscopic images was applied to study the distribution of male specific lethal 1 (MSL-1), a nuclear protein involved in dosage compensation in Drosophila melanogaster, which ensures that males with single X chromosome have the same amount of most X-linked gene products as females with two X chromosomes. Tomographic reconstructions of X-ray microscopic images were used to compute the local three-dimensional linear absorption coefficient revealing the arrangement of internal structures of Drosophila melanogaster cells. Combined with labelling techniques, nanotomography is a new technique to study the 3D distribution of selected proteins inside whole cells. We want to improve this technique with respect to resolution and specimen preparation. The resolution in the reconstruction can be significantly improved by reducing the angular step size to collect more viewing angles, which requires an automated data acquisition. In addition, fast-freezing with liquid ethane instead of cryogenic He gas will be applied to improve the vitrification of the hydrated samples. We also plan to apply cryo X-ray nanotomography in order to study different types of cells and their nuclear protein distributions.

  18. The Western Denmark Cardiac Computed Tomography Registry

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Nørgaard, Bjarne Linde; Tilsted, Hans Henrik;

    2015-01-01

    BACKGROUND: As a subregistry to the Western Denmark Heart Registry (WDHR), the Western Denmark Cardiac Computed Tomography Registry (WDHR-CCTR) is a clinical database established in 2008 to monitor and improve the quality of cardiac computed tomography (CT) in Western Denmark. OBJECTIVE: We...

  19. [Computed tomography and cranial paleoanthropology].

    Science.gov (United States)

    Cabanis, Emmanuel Alain; Badawi-Fayad, Jackie; Iba-Zizen, Marie-Thérèse; Istoc, Adrian; de Lumley, Henry; de Lumley, Marie-Antoinette; Coppens, Yves

    2007-06-01

    Since its invention in 1972, computed tomography (C.T.) has significantly evolved. With the advent of multi-slice detectors (500 times more sensitive than conventional radiography) and high-powered computer programs, medical applications have also improved. CT is now contributing to paleoanthropological research. Its non-destructive nature is the biggest advantage for studying fossil skulls. The second advantage is the possibility of image analysis, storage, and transmission. Potential disadvantages include the possible loss of files and the need to keep up with rapid technological advances. Our experience since the late 1970s, and a recent PhD thesis, led us to describe routine applications of this method. The main contributions of CT to cranial paleoanthropology are five-fold: --Numerical anatomy with rapid acquisition and high spatial resolution (helicoidal and multidetector CT) offering digital storage and stereolithography (3D printing). --Numerical biometry (2D and 3D) can be used to create "normograms" such as the 3D craniofacial reference model used in maxillofacial surgery. --Numerical analysis offers thorough characterization of the specimen and its state of conservation and/or restoration. --From "surrealism" to virtual imaging, anatomical structures can be reconstructed, providing access to hidden or dangerous zones. --The time dimension (4D imaging) confers movement and the possibility for endoscopic simulation and internal navigation (see Iconography). New technical developments will focus on data processing and networking. It remains our duty to deal respectfully with human fossils. PMID:18402165

  20. Computed tomography and three-dimensional imaging

    International Nuclear Information System (INIS)

    Presented here is a brief introduction to two-, three-, and four-dimensional computed tomography. More detailed descriptions of the mathematics of reconstruction and of CT scanner operation are presented elsewhere. The complementary tomographic imaging methods of single-photon-emission tomography (SPECT) positron-emission tomography (PET), nuclear magnetic resonance (NMR) imaging, ulltrasound sector scanning, and ulltrasound computer-assisted tomography [UCAT] are only named here. Each imaging modality ''probes'' the body with a different energy form, yielding unique and useful information about tomographic sections through the body

  1. Fracture of the orbit: computed tomography appearance

    International Nuclear Information System (INIS)

    The main mechanisms of orbital fractures and their clinical symptoms are exposed. The computed tomographic appearance is described and the implication of computed tomography for therapeutic indications is evaluated as a function of clinical symptoms: visual impairment, anomaly of pupillary reaction to light, ophthalmoplegia, exophthalmos and associated injuries such as intracranial hematomas. The role of computed tomography for the follow-up of these patients is considered

  2. Computed tomography of the kidney

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Young Kyun; Lee, Sun Wha; Kim, Soon Yong [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1980-12-15

    It is generally accepted that the computed tomography is an extremely accurate means to obtain more definite information on the diagnosis of renal masses, although the conventional excretory urography remains the primary tool in the diagnosis of renal disorders. The authors studied 62 cases of proven renal disorders among 758 abdominal CT scans performed during the period from Oct. 1977 to Jan. 1980 in Kyung Hee University Hospital. The results were as follows: 1. Of 23 simple renal cyst cases, 20 cases were found incidentally and 17 of them were over 50 years of age. 2. The CT scan have proved to be an extremely accurate means in differentiating benign renal cyst from neoplastic origin; based on attenuation value, demarcation from normal renal parenchyme and thickness of wall, especially the attenuation value. 3. CT scan holds great promise in diagnosing renal tumors, especially in staging of tumor and determining surgical feasibility and its approach. 4. Pathology and its extension of retroperitoneal space was demonstrated accurately by CT and cause of nonfunctioning kidney could be often explained without retrograde pyelography. 5. Associated polycystic changes in liver, spleen and pancreas to polycystic kidney was easily diagnosed by CT alone.

  3. X-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kalender, Willi A [Institute of Medical Physics, University Erlangen-Nuernberg, Henkestr. 91, D-91052 Erlangen (Germany)

    2006-07-07

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention. (review)

  4. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  5. Quantitative computed tomography evaluation of pulmonary disease

    DEFF Research Database (Denmark)

    McEvoy, Fintan; Buelund, Lene Elisabeth; Strathe, Anders Bjerring;

    2009-01-01

    Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present.......Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present....

  6. Computed tomography in abnormalities of the hip

    International Nuclear Information System (INIS)

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip join can be measured by means of computed tomography. (Auth.)

  7. Examination of weld defects by computed tomography

    Directory of Open Access Journals (Sweden)

    M. Jovanović

    2012-04-01

    Full Text Available Defects in metal arc gas (MAG welds made in S235JR low carbon steel of 6 mm thickness were examined. A sample containing lack of fusion (LOF and pores was examined by computed tomography – CT. The computed tomography examination was performed in order to define LOF size and position as well as dimensions and distribution of accompanying pores in the weld metal.

  8. Computer axial tomography in geosciences

    International Nuclear Information System (INIS)

    Computer Axial Tomography (CAT) is one of the most adequate non-invasive techniques for the investigation of the internal structure of a large category of objects. Initially designed for medical investigations, this technique, based on the attenuation of X- or gamma-ray (and in some cases neutrons), generates digital images which map the numerical values of the linear attenuation coefficient of a section or of the entire volume of the investigated sample. Shortly after its application in medicine, CAT has been successfully used in archaeology, life sciences, and geosciences as well as for the industrial materials non-destructive testing. Depending on the energy of the utilized radiation as well as on the effective atomic number of the sample, CAT can provide with a spatial resolution of 0.01 - 0.5 mm, quantitative as well as qualitative information concerning local density, porosity or chemical composition of the sample. At present two types of axial Computer Tomographs (CT) are in use. One category, consisting of medical as well as industrial CT is equipped with X-ray tubes while the other uses isotopic gamma-ray sources. CT provided with intense X-ray sources (equivalent to 12-15 kCi or 450-550 TBq) has the advantage of an extremely short running time (a few seconds and even less) but presents some disadvantages known as beam hardening and absorption edge effects. These effects, intrinsically related to the polychromatic nature of the X-rays generated by classical tubes, need special mathematical or physical corrections. A polychromatic X-ray beam can be made almost monochromatic by means of crystal diffraction or by using adequate multicomponent filters, but these devices are costly and considerably diminish the output of X-ray generators. In the case of CT of the second type, monochromatic gamma-rays generated by radioisotopic sources, such as 169 Yb (50.4 keV), 241 Am (59 keV), 192 Ir (310.5 and 469.1 keV ) or 137 Cs (662.7 keV), are used in combination with

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... a gantry, which rotates around the patient. The computer that processes the imaging information and monitor are ...

  10. Evaluation of laryngeal carcinoma by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Jeong Ho; Kim, Su Mi; Lee, Sun Wha; Eun, Tchung Ki; Kim, Soon Yong [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1984-09-15

    The limitation of direct or indirect laryngoscopy and laryngogram in determining the exact site and anatomic location of laryngeal carcinoma were well documented by many authors. As compared with laryngoscopy and laryngogram, computed tomographic study for laryngeal cancer is more exact and accurate method demonstrating anatomic sites of involvement, invasion into deep soft tissue spaces of endolarynx, destruction of laryngeal cartilages and cervical metastasis. Fourteen laryngeal cancer patients proven by laryngoscopic biopsy were further examined by computed tomography for staging. The authors compared laryngoscopic findings with those of computed tomography, and their clinical, surgical and computed tomographic findings were analysed. The results were as follows; 1. All patients were proved as squamous cell carcinoma. They were 12 males and 2 females aged over 50 yr. 2. Common clinical symptoms were hoarsense, dysphagia and swallowing difficulty. The primary anatomic sites determined by CT were 8 transglottic, 2 glottic, 2 supraglottic and 1 pyriform sinus respectively. They were 2 T1, 7 T2,1 T3, 3 T4 by TNM systems, respectively. (One case was difficult to evaluate exactly). 3. Invasion into deep soft tissue spaces of endolarynx, cartilage destruction, and neck metastasis were relatively predominant in transglottic carcinomas. 4. Compute tomography was superior in evaluating tumor invasion, especially into deep sift tissue spaces of endolarynx, laryngeal cartilages and metastasis to soft tissue and lymph nodes of neck. However computed tomography had some limitation in determining primary site of laryngeal cancer.

  11. Usefulness of computed tomography in recurrent nephrolithiasis

    International Nuclear Information System (INIS)

    For five cases of recurrent stone formers we performed Computed Tomography, which revealed non-visualized small stones on KUB and uric acid stones. Case 1 was primary hyperparathyroidism. Case 2 had several episodes of spontaneous stone passage without any stone shadow on routine X-ray examination. Case 3 had single ureteral stone on X-ray film. Case 4 had several episodes of spontaneous passage of mixed stones (uric acid and calcium oxalate). Case 5 had bilateral radiolucent large renal stones. We emphasized the superiority of Computed Tomography in search and prophylactic therapy of the stone formation. (author)

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... a gantry, which rotates around the patient. The computer that processes the imaging information and monitor are located in ... ray beam follows a spiral path. A special computer program processes this series of pictures, or slices of the ...

  13. Paradoxical emboli: demonstration using helical computed tomography of the pulmonary artery associated with abdominal computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Delalu, P.; Ferretti, G.R.; Bricault, I.; Ayanian, D.; Coulomb, M. [Service Central de Radiologie et Imagerie Medicale, CHU Grenoble (France)

    2000-02-01

    We report the case of a 60-year-old woman with a recent history of a cerebrovascular accident. Because of clinical suspicion of pulmonary embolism and negative Doppler ultrasound findings of the lower limbs, spiral computed tomography of the pulmonary artery was performed and demonstrated pulmonary emboli. We emphasize the role of computed tomography of the abdomen, performed 3 min after the thoracic acquisition, which showed an unsuspected thrombus within the abdominal aorta and the left renal artery with infarction of the left kidney. Paradoxical embolism was highly suspected on computed tomography data and confirmed by echocardiography which demonstrated a patent foramen ovale. (orig.)

  14. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which are then displayed on a monitor. Special software can also generate three-dimensional (3-D) images ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ...

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed ...

  16. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten;

    2013-01-01

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...

  17. Neutron computed tomography of rat lungs

    International Nuclear Information System (INIS)

    Using conventional methods, three-dimensional imaging of the lung is challenging because of the low contrast between air and tissue and the large differences in dimensions between various pulmonary structures. The small distal airway structures and the high air-to-tissue ratio of lung tissue require an imaging technique which reliably discriminates between air and water. The objective of this study was to assess whether neutron computed tomography would satisfy such a requirement. This method utilizes the unique characteristic of neutrons of directly interacting with the atomic nucleus rather than being scattered by the atomic shell. Neutron computed tomography was tested in rats and allowed differentiation of larger lung structures (e.g., lobes) and distal airways. Airways could be identified reliably down to the sixth bronchial generation, in some cases even down to the tenth generation. The lung could be stabilized for sufficiently long exposure times to achieve an image resolution of 50-60 μm, which is the current physical resolution limit of the neutron computed tomography facility. Neutron computed tomography allowed excellent lung imaging without the need for additional tissue preparation or contrast media. The enhanced structural resolution obtained by applying this new research technique may improve understanding of lung physiology and respiratory therapy. (note)

  18. Cone beam computed tomography in veterinary dentistry

    NARCIS (Netherlands)

    B. van Thielen; F. Siguenza; B. Hassan

    2012-01-01

    The purpose of this study was to assess the feasibility of cone beam computed tomography (CBCT) in imaging dogs and cats for diagnostic dental veterinary applications. CBCT scans of heads of six dogs and two cats were made. Dental panoramic and multi-planar reformatted (MPR) para-sagittal reconstruc

  19. Computed tomography scanning during a traumatic resuscitation

    NARCIS (Netherlands)

    L.F.M. Beenen; R. Adams; R.W. Koster; T. Otto

    2011-01-01

    In cardiopulmonary resuscitation, computed tomography (CT) imaging could be of decisive importance to therapeutic strategy making but is yet unavailable because of incompatibility of CT scanning and manual chest compressions. In this report, we describe a case in which CT scanning was performed on a

  20. Neutron computed tomography of rat lungs

    Energy Technology Data Exchange (ETDEWEB)

    Metzke, R W; Wall, W A [Institute for Computational Mechanics at Technische Universitaet Muenchen, 85747 Garching (Germany); Runck, H; Stahl, C A; Schneider, M; Guttmann, J [Department of Anesthesiology, Section for Experimental Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany); Schillinger, B; Calzada, E; Muehlbauer, M; Schulz, M [Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM-II) and Fakultaet fuer Physik E21 at Technische Universitaet Muenchen, 85748 Garching (Germany); Priebe, H-J, E-mail: metzke@lnm.mw.tum.d [Department of Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany)

    2011-01-07

    Using conventional methods, three-dimensional imaging of the lung is challenging because of the low contrast between air and tissue and the large differences in dimensions between various pulmonary structures. The small distal airway structures and the high air-to-tissue ratio of lung tissue require an imaging technique which reliably discriminates between air and water. The objective of this study was to assess whether neutron computed tomography would satisfy such a requirement. This method utilizes the unique characteristic of neutrons of directly interacting with the atomic nucleus rather than being scattered by the atomic shell. Neutron computed tomography was tested in rats and allowed differentiation of larger lung structures (e.g., lobes) and distal airways. Airways could be identified reliably down to the sixth bronchial generation, in some cases even down to the tenth generation. The lung could be stabilized for sufficiently long exposure times to achieve an image resolution of 50-60 {mu}m, which is the current physical resolution limit of the neutron computed tomography facility. Neutron computed tomography allowed excellent lung imaging without the need for additional tissue preparation or contrast media. The enhanced structural resolution obtained by applying this new research technique may improve understanding of lung physiology and respiratory therapy. (note)

  1. Lung Nodule Detection in Screening Computed Tomography

    CERN Document Server

    Gori, I; Cerello, P; Cheran, S C; De Nunzio, G; Fantacci, M E; Kasae, P; Masala, G L; Pérez-Martínez, A; Retico, A

    2007-01-01

    A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector helical Computed Tomography (CT) images with 1.25 mm slice thickness is presented. The basic modules of our lung-CAD system, a dot-enhancement filter for nodule candidate selection and a neural classifier for false-positive finding reduction, are described. The results obtained on the collected database of lung CT scans are discussed.

  2. Parallel Computing for the Computed-Tomography Imaging Spectrometer

    Science.gov (United States)

    Lee, Seungwon

    2008-01-01

    This software computes the tomographic reconstruction of spatial-spectral data from raw detector images of the Computed-Tomography Imaging Spectrometer (CTIS), which enables transient-level, multi-spectral imaging by capturing spatial and spectral information in a single snapshot.

  3. Computed tomography of tuberculous meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Noriko; Sato, Hiromi; Kawaguchi, Tetsuro; Fujita, Katsuzo; Tanaka, Makoto (Kobe Univ. (Japan). School of Medicine)

    1982-12-01

    Recently, tuberculous meningitis has become rather rare except in areas where tuberculosis is still endemic. Six adolescents and young adults with tuberculous meningitis were evaluated by means of serial computerized tomography (CT), and the results were correlated with the findings of surgical specimens or autopsies. All cases showed meningeal irritation and fever at onset. CSF cultures revealed the presence of tuberculous bacilli. Four cases advanced rapidly to the clinical stage III and expired in a short period-between two weeks to one month from onset. On initial CT scanning, the disappearance of the basal cistern was a characteristic finding in all these cases. With the progression, an enhancement of the basal cistern on contrast injection, a localized hypodensity in adjacent parenchyma, and symmetrical ventricular dilatation appeared. Two autopsied cases showed tuberculous granulomas with purulent materials, thickened meninges, and caseous necrosis in the parenchyma around the basal cistern. The other two cases progressed rather slowly. CT findings at Stage II showed multiple enhanced spots in the basal subcortical area following contrast injection. Tuberculous granulomas were identified in these parts by means of explorative craniotomy. The authors point out the pathognomonic CT findings of tuberculous meningitis and emphasize the necessity of serial CT for the early detection and management of tuberculous meningitis.

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... child may have, and if there is a history of heart disease, asthma, diabetes, kidney disease or ... the patient. The computer that processes the imaging information and monitor are ... in detector technology allow new CT scanners to obtain multiple slices ...

  5. Acute pancreatitis: diagnostic value of ultrasonography and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blery, M.; Hautefeuille, P.; Jacquenod, P. and others

    1987-09-01

    The value of ultrasonography and computed tomography for the diagnosis, extension, pronostic, complications and etiology of acute pancreatitis is discussed. Ultrasonography and computed tomography guided interventional radiology techniques are valuable in the management of pancreatitis complications such as abscesses.

  6. Acute pancreatitis: diagnostic value of ultrasonography and computed tomography

    International Nuclear Information System (INIS)

    The value of ultrasonography and computed tomography for the diagnosis, extension, pronostic, complications and etiology of acute pancreatitis is discussed. Ultrasonography and computed tomography guided interventional radiology techniques are valuable in the management of pancreatitis complications such as abscesses

  7. Cerebral candidiasis. Computed tomography appearance

    Energy Technology Data Exchange (ETDEWEB)

    Chaabane, M.; Ladeb, M.F.; Bouhaouala, M.H.; Ben Hammouda, M.; Ataalah, R.; Gannouni, A.; Krifa, H.

    1989-07-01

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.).

  8. Cerebral candidiasis. Computed tomography appearance

    International Nuclear Information System (INIS)

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.)

  9. Introducing Seismic Tomography with Computational Modeling

    Science.gov (United States)

    Neves, R.; Neves, M. L.; Teodoro, V.

    2011-12-01

    Learning seismic tomography principles and techniques involves advanced physical and computational knowledge. In depth learning of such computational skills is a difficult cognitive process that requires a strong background in physics, mathematics and computer programming. The corresponding learning environments and pedagogic methodologies should then involve sets of computational modelling activities with computer software systems which allow students the possibility to improve their mathematical or programming knowledge and simultaneously focus on the learning of seismic wave propagation and inverse theory. To reduce the level of cognitive opacity associated with mathematical or programming knowledge, several computer modelling systems have already been developed (Neves & Teodoro, 2010). Among such systems, Modellus is particularly well suited to achieve this goal because it is a domain general environment for explorative and expressive modelling with the following main advantages: 1) an easy and intuitive creation of mathematical models using just standard mathematical notation; 2) the simultaneous exploration of images, tables, graphs and object animations; 3) the attribution of mathematical properties expressed in the models to animated objects; and finally 4) the computation and display of mathematical quantities obtained from the analysis of images and graphs. Here we describe virtual simulations and educational exercises which enable students an easy grasp of the fundamental of seismic tomography. The simulations make the lecture more interactive and allow students the possibility to overcome their lack of advanced mathematical or programming knowledge and focus on the learning of seismological concepts and processes taking advantage of basic scientific computation methods and tools.

  10. Practical management of computed tomography

    International Nuclear Information System (INIS)

    For examinations of the spinal canal is used computed myelography as an adjunct to water-soluble conventional myelography. For CT alone about 3.5 g. of metrizamide in isotonic solution is adequate for all investigations. If the constrast medium has to be run into the head by gravity, as in the detection of cerebrospinal fluid fistula or empty sella, or for detailed examination of the basal cisterns, phenobarbitone 100 mg. t.d.s. is commenced on the eve of the examination and continued for 48 hours. A similar dose is also administered to epileptic subject. If fits should occur they are treated with intravenous diazepam and prophylactic phenobarbitone is administered. (orig./AJ)

  11. Cone beam computed tomography in endodontic

    Energy Technology Data Exchange (ETDEWEB)

    Durack, Conor; Patel, Shanon, E-mail: conordurack1@hotmail.com [Unit of Endodontology, Department of Conservative Dentistry, King' s College London, London (United Kingdom)

    2012-07-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  12. Contrast-induced nephropathy after computed tomography

    Directory of Open Access Journals (Sweden)

    Luciano da Silva Selistre

    2015-03-01

    Full Text Available Introduction: Contrast induced nephropathy is the third most prevalent preventable cause of acute kidney injury in hospitalized patients. It defined as an absolute increase in serum creatinine ≥ 0.5 mg/dL and relative ≥ 25% increase. Objective: We studied the risk factors to intravenous injection contrast nephropathy after computed tomography. Methods: We studied 400 patients prospectively. Results: The incidence of contrast induced nephropathy, with an absolute or a relative increase were 4.0% and 13.9%, respectively. Diabetes and cardiac failure were independent risk factors for CIN a relative increase de serum creatinine (O.R.: 3.5 [95% CI: 1.92-6.36], p < 0.01, 2.61 [95% CI: 1.14-6.03%], p < 0.05, respectively. Conclusions: We showed association between uses of intravenous injection contrast after computed tomography with acute injury renal, notably with diabetes and heart failure.

  13. Possibilities of computer tomography in multiple sclerosis

    International Nuclear Information System (INIS)

    Computer tomography was performed in 41 patients with multiple sclerosis, the average age of patients being 40.8 years. Native examinations were made of 17 patients, examinations with contrast medium of 19, both methods were used in the examination of 5 patients. In 26 patients, i.e. in almost two-thirds, cerebral atrophy was found, in 11 of a severe type. In 9 patients atrophy affected only the hemispheres, in 16 also the stem and cerebellum. The stem and cerebellum only were affected in 1 patient. Hypodense foci were found in 21 patients, i.e. more than half of those examined. In 9 there were multiple foci. In most of the 19 examined patients the hypodense changes were in the hemispheres and only in 2 in the cerebellum and brain stem. No hyperdense changes were detected. The value and possibilities are discussed of examinations by computer tomography multiple sclerosis. (author)

  14. Biliary obstruction: Helical computed tomography cholangiography evaluation

    International Nuclear Information System (INIS)

    Helical computed tomography cholangiography (HCTC) takes advantage of the improvement in the quality of multiplanar and three-dimensional reconstructions resulting from the volumetric acquisition of data achieved with helical computed tomography and the indirect opacification of the bile ducts provided by cholangiographic contrast media. This method was used to evaluate 31 patients with suspected biliary obstruction over a one-year period and the findings were compared with those of direct cholangiography and/or surgery. Biliary opacification was sufficient to allow three-dimensional reconstructions in 90,3% of cases. Sensitivity was 81% for the diagnosis of choledochoolithiasis and 100% for ascariasis, choledochal cysts and anatomic variants of the biliary tree. Our results indicate that HCTC is a valuable alternative as a diagnostic method prior to direct cholangiography. Direct cholangiography should be reserved for those patients who require it as part of a therapeutic procedure

  15. [Pneumothorax revealed by postoperative computed tomography].

    Science.gov (United States)

    Ikeda, Shizuka; Katori, Kiyoshi; Fujimoto, Minoru; Nitahara, Keiichi; Higa, Kazuo

    2005-11-01

    We report a case of pneumothorax revealed by postoperative computed tomography. A 39-year-old obese woman (height 153 cm, weight 70 kg) with fractures of the radius, ulna, clavicle, and femur in a traffic accident, was scheduled for osteosynthesis. Anesthesia was induced with thiopental and maintained with 50% nitrous oxide in oxygen and sevoflurane. The Spo2 decreased from 99% to 94% during the surgery. Bilateral chest sounds were symmetrical. The Spo2 increased to 100% after discontinuation of nitrous oxide. Pneumothorax was not evident on a postoperative chest X-ray, but computed tomography of the chest demonstrated right-sided pneumothorax. An ECG electrode had overlapped the fractured rib on the preoperative chest X-ray.

  16. Cone beam computed tomography in endodontic

    International Nuclear Information System (INIS)

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  17. Computed Tomography of Transverse Phase Space

    Energy Technology Data Exchange (ETDEWEB)

    Watts, A. [Fermilab; Johnstone, C. [Fermilab; Johnstone, J. [Fermilab

    2016-09-19

    Two computed tomography techniques are explored to reconstruct beam transverse phase space using both simulated beam and multi-wire profile data in the Fermilab Muon Test Area ("MTA") beamline. Both Filtered Back-Projection ("FBP") and Simultaneous Algebraic Reconstruction Technique ("SART") algorithms [2] are considered and compared. Errors and artifacts are compared as a function of each algorithm’s free parameters, and it is shown through simulation and MTA beamline profiles that SART is advantageous for reconstructions with limited profile data.

  18. Computed tomography of ancient Egyptian mummies.

    Science.gov (United States)

    Harwood-Nash, D C

    1979-12-01

    This first report of the application of computed tomography (CT) to the study of ancient mummies, the desiccated brain of a boy and the body of a young woman within her cartonnage, shows that CT is uniquely suitable for the study of such antiquities, a study that does not necessitate destruction of the mummy or its cartonnage. Exquisite images result that are of great paleoanatomical, paleopathological, and archeological significance.

  19. Dynamic computed tomography of the brain

    International Nuclear Information System (INIS)

    Dynamic computed tomography (CT) studies of the brain are based on a rapid intravenous bolus injection of radiographic contrast material immediately followed by serial CT scans. The recycling times for this technique are 1 sec or less. Dynamic studies, which are relatively non-invasive, add considerable information to the static cerebral scan as it is presently performed. The resulting time-density patterns are described and typical examples of each are shown. (orig.)

  20. Improvement in computed tomography spatial resolution

    International Nuclear Information System (INIS)

    One of the most important recent developments in transmission computed tomography is the improvement in spatial resolution. Applications of this technical advance to the neuroradiographic exploration of such structures as spinal cord, nerve roots and pituitary gland - as well as the orbits and inner and middle ear - is still limited to a few centers. Increased spatial resolution appears to be an effective means to increase our diagnostic capabilities. The higher dosimetry connected with this modality needs to be emphasized. (orig.)

  1. Encapsulating peritonitis: computed tomography and surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kadow, Juliana Santos; Fingerhut, Carla Jeronimo Peres; Fernandes, Vinicius de Barros; Coradazzi, Klaus Rizk Stuhr; Silva, Lucas Marciel Soares; Penachim, Thiago Jose, E-mail: vinicius.barros.fernandes@gmail.com [Pontificia Universidade Catolica de Campinas (PUC-Campinas), Campinas, SP (Brazil). Hospital e Maternidade Celso Pierro

    2014-07-15

    Sclerosing encapsulating peritonitis is a rare and frequently severe entity characterized by total or partial involvement of small bowel loops by a membrane of fibrous tissue. The disease presents with nonspecific clinical features of intestinal obstruction, requiring precise imaging diagnosis to guide the treatment. The present report emphasizes the importance of computed tomography in the diagnosis of this condition and its confirmation by surgical correlation. (author)

  2. Computed tomography in gastrointestinal stromal tumors

    International Nuclear Information System (INIS)

    The aim of this study was to define the imaging characteristics of primary and recurrent gastrointestinal stromal tumors (GIST) in computed tomography with respect to the tumor size. Computed tomography was performed in 35 patients with histologically confirmed gastrointestinal stromal tumors and analyzed retrospectively by two experienced and independent radiologist. The following morphologic tumor characteristics of primary (n=20) and (n=16) recurrent tumors were evaluated according to tumor size, shape, homogeneity, density compared with liver, contrast enhancement, presence of calcifications, ulcerations, fistula or distant metastases and the anatomical relationship to the intestinal wall, and the infiltration of adjacent visceral organs. Small GIST (5-10 cm) demonstrated an irregular shape, inhomogeneous density on unenhanced and contrast-enhanced images, a combined intra- and extraluminal tumor growth with aggressive findings, and infiltration of adjacent organs in 9 primary diagnosed and 2 recurrent tumors. Large GIST (>10 cm), which were observed in 8 primary tumors and 11 recurrent tumors, showed an irregular margin with inhomogeneous density and aggressive findings, and were characterized by signs of malignancy such as distant and peritoneal metastases. Small recurrent tumors had a similar appearance as compared with large primary tumors. Computed tomography gives additional information with respect to the relationship of gastrointestinal stromal tumor to the gastrointestinal wall and surrounding organs, and it detects distant metastasis. Primary and recurrent GIST demonstrate characteristic CT imaging features which are related to tumor size. Aggressive findings and signs of malignancy are found in larger tumors and in recurrent disease. Computed tomography is useful in detection and characterization of primary and recurrent tumors with regard to tumor growth pattern, tumor size, and varied appearances of gastrointestinal stromal tumors, and indirectly

  3. Computed tomography in gastrointestinal stromal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Ghanem, Nadir; Altehoefer, Carsten; Winterer, Jan; Schaefer, Oliver; Springer, Oliver; Kotter, Elmar; Langer, Mathias [Department of Diagnostic Radiology, University Hospital Freiburg, Hugstetter Strasse 55, 79106, Freiburg (Germany); Furtwaengler, Alex [Department of Abdominal Surgery, University Hospital Freiburg, Hugstetter Strasse 55, 79106, Freiburg (Germany)

    2003-07-01

    The aim of this study was to define the imaging characteristics of primary and recurrent gastrointestinal stromal tumors (GIST) in computed tomography with respect to the tumor size. Computed tomography was performed in 35 patients with histologically confirmed gastrointestinal stromal tumors and analyzed retrospectively by two experienced and independent radiologist. The following morphologic tumor characteristics of primary (n=20) and (n=16) recurrent tumors were evaluated according to tumor size, shape, homogeneity, density compared with liver, contrast enhancement, presence of calcifications, ulcerations, fistula or distant metastases and the anatomical relationship to the intestinal wall, and the infiltration of adjacent visceral organs. Small GIST (<5 cm) showed a sharp tumor margin with homogeneous density and structure on unenhanced and contrast-enhanced images, and were characterized by an intraluminal tumor growth. Intermediate sized GIST (>5-10 cm) demonstrated an irregular shape, inhomogeneous density on unenhanced and contrast-enhanced images, a combined intra- and extraluminal tumor growth with aggressive findings, and infiltration of adjacent organs in 9 primary diagnosed and 2 recurrent tumors. Large GIST (>10 cm), which were observed in 8 primary tumors and 11 recurrent tumors, showed an irregular margin with inhomogeneous density and aggressive findings, and were characterized by signs of malignancy such as distant and peritoneal metastases. Small recurrent tumors had a similar appearance as compared with large primary tumors. Computed tomography gives additional information with respect to the relationship of gastrointestinal stromal tumor to the gastrointestinal wall and surrounding organs, and it detects distant metastasis. Primary and recurrent GIST demonstrate characteristic CT imaging features which are related to tumor size. Aggressive findings and signs of malignancy are found in larger tumors and in recurrent disease. Computed tomography

  4. Analysis of computed tomography of ovarian tumor

    Energy Technology Data Exchange (ETDEWEB)

    Omura, Makoto; Taniike, Keiko; Nishiguchi, Hiroyasu

    1987-07-01

    One hundred and twenty six patients with ovarian mass were studied with computed tomography (CT) and classified into five groups according to its margin and inner structure. The incidence of malignancy of cystic ovarian mass with smooth margin was low and that of solid ovarian mass with irreglar margin was high. Three cases (6.7 %) of malignant ovarian tumor demonstrated completely cystic pattern. Ovarian teratomas contained well defined component of fat density.

  5. HORSESHOE KIDNEY: A MULTIDETECTOR COMPUTED TOMOGRAPHY STUDY

    Directory of Open Access Journals (Sweden)

    Sharma V

    2015-06-01

    Full Text Available Background and Objective: Horseshoe kidney is the most common renal fusion anomaly with a reported prevalence of 1 in 400 persons with a male to female ratio of 2:1. In many cases its presence may go unnoticed and undiagnosed because the patient may remain asymptomatic throughout life. The objective of our study is to report radiological and anatomical features of horseshoe kidney detected incidentally during retrospective evaluation of multidetector computed tomography scans. Materials and Methods: Contrast enhanced multidetector computed tomography scans of 682 patients, 355 males and 327 females, were reviewed retrospectively. Results: Seven cases of horseshoe kidney were detected incidentally, six males and one female, with an incidence of 1.02 %. In all cases, malrotation of the kidneys were observed with the hilum facing anteriorly or anterolaterally. The isthmus was made up of parenchymal tissue in all the cases and the fusion was midline in four cases and lateral in three cases. Horseshoe kidney in all cases was supplied by multiple renal arteries, varying from 3 to 6. In three cases symmetrical arterial supply and in the rest asymmetrical supply was observed. Nephrolithiasis and hydronephrosis were noted in two patients. No other associated congenital anomaly was observed in all seven patients. Conclusion: Contrast enhanced multidetector computed tomography evaluation of patients with horseshoe kidney provide excellent information about its vascularity, collecting system and other associated conditions.

  6. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo; Larsen, Erik;

    The ‘CIA-CT comparison - Inter laboratory comparison on industrial Computed Tomography” is organized by DTU Department of Mechanical Engineering within the Danish project “Centre for Industrial Application of CT scanning - CIA-CT”. The project is co-financed by the Danish Ministry of Science......, Technology and Innovation. The comparison aims to collect information about measurement performance in state-of the-art industrial CT (Computed Tomography) scanning. Since CT scanning has entered the field of manufacturing and coordinate metrology, evaluation of uncertainty of measurement with assessment...

  7. Single photon emission computed tomography-guided Cerenkov luminescence tomography

    Science.gov (United States)

    Hu, Zhenhua; Chen, Xueli; Liang, Jimin; Qu, Xiaochao; Chen, Duofang; Yang, Weidong; Wang, Jing; Cao, Feng; Tian, Jie

    2012-07-01

    Cerenkov luminescence tomography (CLT) has become a valuable tool for preclinical imaging because of its ability of reconstructing the three-dimensional distribution and activity of the radiopharmaceuticals. However, it is still far from a mature technology and suffers from relatively low spatial resolution due to the ill-posed inverse problem for the tomographic reconstruction. In this paper, we presented a single photon emission computed tomography (SPECT)-guided reconstruction method for CLT, in which a priori information of the permissible source region (PSR) from SPECT imaging results was incorporated to effectively reduce the ill-posedness of the inverse reconstruction problem. The performance of the method was first validated with the experimental reconstruction of an adult athymic nude mouse implanted with a Na131I radioactive source and an adult athymic nude mouse received an intravenous tail injection of Na131I. A tissue-mimic phantom based experiment was then conducted to illustrate the ability of the proposed method in resolving double sources. Compared with the traditional PSR strategy in which the PSR was determined by the surface flux distribution, the proposed method obtained much more accurate and encouraging localization and resolution results. Preliminary results showed that the proposed SPECT-guided reconstruction method was insensitive to the regularization methods and ignored the heterogeneity of tissues which can avoid the segmentation procedure of the organs.

  8. Therapy response evaluation with positron emission tomography-computed tomography.

    Science.gov (United States)

    Segall, George M

    2010-12-01

    Positron emission tomography-computed tomography with F-18-fluorodeoxyglucose is widely used for evaluation of therapy response in patients with solid tumors but has not been as readily adopted in clinical trials because of the variability of acquisition and processing protocols and the absence of universal response criteria. Criteria proposed for clinical trials are difficult to apply in clinical practice, and gestalt impression is probably accurate in individual patients, especially with respect to the presence of progressive disease and complete response. Semiquantitative methods of determining tissue glucose metabolism, such as standard uptake value, can be a useful descriptor for levels of tissue glucose metabolism and changes in response to therapy if technical quality control measures are carefully maintained. The terms partial response, complete response, and progressive disease are best used in clinical trials in which the terms have specific meanings and precise definitions. In clinical practice, it may be better to use descriptive terminology agreed upon by imaging physicians and clinicians in their own practice. PMID:21147376

  9. Computed tomography to quantify tooth abrasion

    Science.gov (United States)

    Kofmehl, Lukas; Schulz, Georg; Deyhle, Hans; Filippi, Andreas; Hotz, Gerhard; Berndt-Dagassan, Dorothea; Kramis, Simon; Beckmann, Felix; Müller, Bert

    2010-09-01

    Cone-beam computed tomography, also termed digital volume tomography, has become a standard technique in dentistry, allowing for fast 3D jaw imaging including denture at moderate spatial resolution. More detailed X-ray images of restricted volumes for post-mortem studies in dental anthropology are obtained by means of micro computed tomography. The present study evaluates the impact of the pipe smoking wear on teeth morphology comparing the abraded tooth with its contra-lateral counterpart. A set of 60 teeth, loose or anchored in the jaw, from 12 dentitions have been analyzed. After the two contra-lateral teeth were scanned, one dataset has been mirrored before the two datasets were registered using affine and rigid registration algorithms. Rigid registration provides three translational and three rotational parameters to maximize the overlap of two rigid bodies. For the affine registration, three scaling factors are incorporated. Within the present investigation, affine and rigid registrations yield comparable values. The restriction to the six parameters of the rigid registration is not a limitation. The differences in size and shape between the tooth and its contra-lateral counterpart generally exhibit only a few percent in the non-abraded volume, validating that the contralateral tooth is a reasonable approximation to quantify, for example, the volume loss as the result of long-term clay pipe smoking. Therefore, this approach allows quantifying the impact of the pipe abrasion on the internal tooth morphology including root canal, dentin, and enamel volumes.

  10. Fluorescence Computed Tomography with Polychromatic Source Data

    International Nuclear Information System (INIS)

    Fluorescence computed tomography is a synchrotron imaging technique aiming at reconstructing the fluorescence emission within a sample object. For a polychromatic source hitting the object, the amount of fluorescence detected is defined by a linear equation. For the monochromatic case, the operator is a Generalized Attenuated Radon Transform (GART). The main goal is to reconstruct the density function, given the sinogram data and the weight function. An eficient iterative algorithm for the inversion of the GART was presented recently by the authors. This inversion can only be performed if the weight function is previously known, which means that μ = μ(·, ε) and λ are also known. For monochromatic XFCT (acronym for x-rays fluorescence computed tomography), the determination of λ is a dificult task, and we have considered the approximation λ ≈ μ, which is valid for low energies ranging from 3Kev to 10Kev. So, for solving our problem, the first step is to find μ given the polychromatic sinogram. There are different approaches for this in the literature. Recently, an elegant and efficient method for solving this problem was introduced, using a fixed point algorithm. Opposite to this, where μ(·, ε) needs to be computed for all ε element of E, we claim that the integral of μ(·, ε) for all ε has a physical meaning and provides a good aproximation for the solution. Also we present fast algorithm for computations.

  11. Positron computed tomography: current state, clinical results and future trends

    International Nuclear Information System (INIS)

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends

  12. Computed tomography appearances of sclerosing encapsulating peritonitis

    Energy Technology Data Exchange (ETDEWEB)

    George, C. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)]. E-mail: cheriangeorge@hotmail.com; Al-Zwae, K. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Nair, S. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Cast, J.E.I. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)

    2007-08-15

    Sclerosing encapsulating peritonitis (SEP) is a serious complication of peritoneal dialysis (PD) characterized by thickened peritoneal membranes, which lead to decreased ultra-filtration and intestinal obstruction. Its early clinical features are nonspecific, and it is often diagnosed late following laparotomy and peritoneal biopsy, when the patient develops small bowel obstruction, which can be a life-threatening complication. However, this is changing with increasing awareness of computed tomography (CT) findings in SEP. CT can yield an early, non-invasive diagnosis that may improve patient outcome. We present a review of the CT appearances of SEP.

  13. Multidetector Computed Tomography in Acute Joint Fractures

    Energy Technology Data Exchange (ETDEWEB)

    Haapamaeki, V.V.; Kiuru, M.J.; Mustonen, A.O.; Koskinen, S.K. [Helsinki Univ. Central Hospital (Finland). Helsinki Medical Imaging Center

    2005-10-01

    Conventional radiography plays an essential diagnostic role in the primary evaluation of acute joint trauma. In complex fractures, however, computed tomography (CT) is an imaging modality often used second to radiography. As a result of technical breakthroughs in the field, multidetector CT (MDCT) allows faster imaging and better temporal, spatial, and contrast resolution compared with conventional single-slice spiral CT. MDCT with multiplanar reformation is helpful in disclosing fracture patterns, particularly in complex joint fractures, where they reveal occult fractures and show the exact number of fracture components and their degree of displacement.

  14. Computed tomography studies of human brain movements

    International Nuclear Information System (INIS)

    Rhythmic brain movements have been revealed by sets of sequential computed tomography scans of human brains (seen retrospectively to be normal). These scans have shown that both (unenhanced) brain parenchymal density and the shapes of the elements of the supratentorial ventricular/cisternal system are subject to wave motions having similar periods - ranging from 26 s through 56 s, 77-96 s, 109 s and 224 s to 224 X 2 s (or even longer), with good correlation between peak values. These motions, as well as phase variations between the waves, suggest a peristaltic movement of cerebrospinal fluid through the ventricular/cisternal system with progressive axial damping

  15. Emerging clinical applications of computed tomography

    Science.gov (United States)

    Liguori, Carlo; Frauenfelder, Giulia; Massaroni, Carlo; Saccomandi, Paola; Giurazza, Francesco; Pitocco, Francesca; Marano, Riccardo; Schena, Emiliano

    2015-01-01

    X-ray computed tomography (CT) has recently been experiencing remarkable growth as a result of technological advances and new clinical applications. This paper reviews the essential physics of X-ray CT and its major components. Also reviewed are recent promising applications of CT, ie, CT-guided procedures, CT-based thermometry, photon-counting technology, hybrid PET-CT, use of ultrafast-high pitch scanners, and potential use of dual-energy CT for material differentiations. These promising solutions and a better knowledge of their potentialities should allow CT to be used in a safe and effective manner in several clinical applications. PMID:26089707

  16. Computed tomography of cardiac pseudotumors and neoplasms.

    Science.gov (United States)

    Anavekar, Nandan S; Bonnichsen, Crystal R; Foley, Thomas A; Morris, Michael F; Martinez, Matthew W; Williamson, Eric E; Glockner, James F; Miller, Dylan V; Breen, Jerome F; Araoz, Philip A

    2010-07-01

    Important features of cardiac masses can be clearly delineated on cardiac computed tomography (CT) imaging. This modality is useful in identifying the presence of a mass, its relationship with cardiac and extracardiac structures, and the features that distinguish one type of mass from another. A multimodality approach to the evaluation of cardiac tumors is advocated, with the use of echocardiography, CT imaging and magnetic resonance imaging as appropriately indicated. In this article, various cardiac masses are described, including pseudotumors and true cardiac neoplasms, and the CT imaging findings that may be useful in distinguishing these rare entities are presented. PMID:20705174

  17. Comparison on Computed Tomography using industrial items

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    2014-01-01

    In a comparison involving 27 laboratories from 8 countries, measurements on two common industrial items, a polymer part and a metal part, were carried out using X-ray Computed Tomography. All items were measured using coordinate measuring machines before and after circulation, with reference...... measurement uncertainties in the range 1.5–5.5 μm, showing a good stability over the 6 months of the circulation. The comparison has shown that CT measurements on the industrial parts used lie in the range 6–53 μm, with maximum values up to 158 μm....

  18. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning ...... for their measurements. The industrial items are suitable artefacts for CT measurements of this kind, and each participant has been offered to keep a set used for the measurements in the comparison.......An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning...... - CIA-CT”. In the comparison, 27 laboratories from 8 countries were involved, and CT scanned two items selected among common industrial parts: a polymer part and a metal part. Altogether, 27 sets of items were circulated in parallel to the participants. Different measurands are considered, encompassing...

  19. COMPUTED TOMOGRAPHY OF TOOTH RESORPTION IN CATS.

    Science.gov (United States)

    Lang, Linda G; Wilkinson, Thomas E; White, Tammy L; Farnsworth, Raelynn K; Potter, Kathleen A

    2016-09-01

    Tooth resorption is the most common dental disease in cats and can be a source of oral pain. The current clinical gold standard for diagnosis includes a combination of oral exam and dental radiography, however early lesions are not always detected. Computed tomography (CT) of the skull, including the dental arches, is a commonly performed diagnostic procedure, however the appearance of tooth resorption on CT and the diagnostic ability of CT to detect tooth resorption have not been evaluated. The purpose of this prospective, descriptive, diagnostic accuracy study was to characterize the CT appearance of tooth resorption in a sample of affected cats and to evaluate the sensitivity and specificity of CT for tooth resorption compared to the clinical gold standard of oral exam and intraoral dental radiography. Twenty-eight cat cadaver specimens were recruited for inclusion. Each specimen was evaluated using oral exam, intraoral dental radiography, and computed tomography (four different slice thicknesses). Each tooth was evaluated for the presence or absence of tooth resorption. Teeth with lesions and a subset of normal teeth were evaluated with histopathology. On CT, tooth resorption appeared as irregularly marginated hypoattenuating defects in the mineral attenuating tooth components, most commonly involving the root or cementoenamel junction. Sensitivity for CT detection of tooth resorption was fair to poor (42.2-57.7%) and specificity was good to excellent (92.8-96.3%). Findings from this study indicated that CT has high specificity but low sensitivity for detection of tooth resorption in cats.

  20. Emerging clinical applications of computed tomography

    Directory of Open Access Journals (Sweden)

    Liguori C

    2015-06-01

    Full Text Available Carlo Liguori,1 Giulia Frauenfelder,2 Carlo Massaroni,3 Paola Saccomandi,3 Francesco Giurazza,4 Francesca Pitocco,4 Riccardo Marano,5 Emiliano Schena,3 1Radiology Unit, AORN A Cardarelli, 2Radiology Unit, AOU Federico II, Naples, 3Measurement and Biomedical Instrumentation Unit, 4Radiology Unit, Università Campus Bio-Medico di Roma, 5Department of Radiological Sciences, Institute of Radiology, Catholic University of Rome, A Gemelli University Hospital, Rome, Italy Abstract: X-ray computed tomography (CT has recently been experiencing remarkable growth as a result of technological advances and new clinical applications. This paper reviews the essential physics of X-ray CT and its major components. Also reviewed are recent promising applications of CT, ie, CT-guided procedures, CT-based thermometry, photon-counting technology, hybrid PET-CT, use of ultrafast-high pitch scanners, and potential use of dual-energy CT for material differentiations. These promising solutions and a better knowledge of their potentialities should allow CT to be used in a safe and effective manner in several clinical applications. Keywords: computed tomography, X-ray, thermometry, dual-energy, ultrafast scanner, guidance, photon-counting technology

  1. Computed tomography of juvenile nasopharyngeal angiofibroma

    International Nuclear Information System (INIS)

    It is well known that computed tomography (CT) is useful in detecting accurately the location, extent, erosion and relationship of angiofibroma to surrounding structures such as pterygopalation fossa. It is well known that computed tomography (CT) is useful in detecting accurately the location, sphenoid sinus, and etc. CT of 20 patients with juvenile angiofibroma, which were examined for 5 yeas from February, 1979 to May, 1984 at Department of Radiology, Seoul National University Hospital, were retrospectively analyzed. The results were as follows: 1. All 20 patients of juvenile angiofibroma had tumors in nasopharynx and posterior nasal cavity showing homogeneously dense-enhancing soft tissue mass on CT. There was extension of the tumor from nasopharynx and posterior nasal cavity into paranasal sinus (60%, 12/20), pterygopalatine fossa (55%, 11/20), infratemporal fossa (30%, 6/20), posterior orbit (10%, 2/20) and cranial cavity (15%, 3/20). 2. Angiogrpahy usually adds little diagnostic information, but is still needed to identify the precise source of blood supply to the tumor, and to perform the pre-operative embolization. The use of CT has deferred angiography until just before surgery, permitting embolization at optimal time. 3. CT is almost always necessary to reveal accurately the full extent of the tumor, especially intracranial space in the axial and coronal planes with contrast enhancement. CT is useful both in diagnosis as a guide to angiography and in planning the adequate therapy of juvenile angiofibroma

  2. Introduction to neutron stimulated emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Floyd, Carey E Jr [Department of Biomedical Engineering and Department of Radiology, Duke Advanced Imaging Laboratories Box 2623DUMC, Duke University, Durham, NC 27710 (United States); Bender, Janelle E [Department of Biomedical Engineering and Department of Radiology, Duke Advanced Imaging Laboratories Box 2623DUMC, Duke University, Durham, NC 27710 (United States); Sharma, Amy C [Department of Biomedical Engineering and Department of Radiology, Duke Advanced Imaging Laboratories Box 2623DUMC, Duke University, Durham, NC 27710 (United States); Kapadia, Anuj [Department of Biomedical Engineering and Department of Radiology, Duke Advanced Imaging Laboratories Box 2623DUMC, Duke University, Durham, NC 27710 (United States); Xia, Jessie [Department of Biomedical Engineering and Department of Radiology, Duke Advanced Imaging Laboratories Box 2623DUMC, Duke University, Durham, NC 27710 (United States); Harrawood, Brian [Department of Radiology, Duke Advanced Imaging Laboratories Box 3202DUMC, Duke University, Durham, NC 27710 (United States); Tourassi, Georgia D [Department of Radiology, Duke Advanced Imaging Laboratories Box 3202DUMC, Duke University, Durham, NC 27710 (United States); Lo, Joseph Y [Department of Radiology, Duke Advanced Imaging Laboratories Box 3202DUMC, Duke University, Durham, NC 27710 (United States); Crowell, Alexander [Department of Physics and Triangle Universities Nuclear Laboratory, Duke University, Durham, NC 27710 (United States); Howell, Calvin [Department of Physics and Triangle Universities Nuclear Laboratory, Duke University, Durham, NC 27710 (United States)

    2006-07-21

    Neutron stimulated emission computed tomography (NSECT) is presented as a new technique for in vivo tomographic spectroscopic imaging. A full implementation of NSECT is intended to provide an elemental spectrum of the body or part of the body being interrogated at each voxel of a three-dimensional computed tomographic image. An external neutron beam illuminates the sample and some of these neutrons scatter inelastically, producing characteristic gamma emission from the scattering nuclei. These characteristic gamma rays are acquired by a gamma spectrometer and the emitting nucleus is identified by the emitted gamma energy. The neutron beam is scanned over the body in a geometry that allows for tomographic reconstruction. Tomographic images of each element in the spectrum can be reconstructed to represent the spatial distribution of elements within the sample. Here we offer proof of concept for the NSECT method, present the first single projection spectra acquired from multi-element phantoms, and discuss potential biomedical applications.

  3. Spatiotemporal computed tomography of dynamic processes

    Science.gov (United States)

    Kaestner, Anders; Münch, Beat; Trtik, Pavel; Butler, Les

    2011-12-01

    Modern computed tomography (CT) equipment allowing fast 3-D imaging also makes it possible to monitor dynamic processes by 4-D imaging. Because the acquisition time of various 3-D-CT systems is still in the range of at least milliseconds or even hours, depending on the detector system and the source, the balance of the desired temporal and spatial resolution must be adjusted. Furthermore, motion artifacts will occur, especially at high spatial resolution and longer measuring times. We propose two approaches based on nonsequential projection angle sequences allowing a convenient postacquisition balance of temporal and spatial resolution. Both strategies are compatible with existing instruments, needing only a simple reprograming of the angle list used for projection acquisition and care with the projection order list. Both approaches will reduce the impact of artifacts due to motion. The strategies are applied and validated with cold neutron imaging of water desorption from originally saturated particles during natural air-drying experiments and with x-ray tomography of a polymer blend heated during imaging.

  4. Multidetector row computed tomography may accurately estimate plaque vulnerability. Does MDCT accurately estimate plaque vulnerability? (Pro)

    International Nuclear Information System (INIS)

    Over the past decade, multidetector row computed tomography (MDCT) has become the most reliable and established of the noninvasive examination techniques for detecting coronary heart disease. Now MDCT is chasing intravascular ultrasound (IVUS) in terms of spatial resolution. Among the components of vulnerable plaque, MDCT may detect lipid-rich plaque, the lipid pool, and calcified spots using computed tomography number. Plaque components are detected by MDCT with high accuracy compared with IVUS and angioscopy when assessing vulnerable plaque. The TWINS study and TOGETHAR trial demonstrated that angioscopic loss of yellow color occurred independently of volumetric plaque change by statin therapy. These 2 studies showed that plaque stabilization and regression reflect independent processes mediated by different mechanisms and time course. Noncalcified plaque and/or low-density plaque was found to be the strongest predictor of cardiac events, regardless of lesion severity, and act as a potential marker of plaque vulnerability. MDCT may be an effective tool for early triage of patients with chest pain who have a normal electrocardiogram (ECG) and cardiac enzymes in the emergency department. MDCT has the potential ability to analyze coronary plaque quantitatively and qualitatively if some problems are resolved. MDCT may become an essential tool for detecting and preventing coronary artery disease in the future. (author)

  5. Perfusion computed tomography imaging of autoimmune pancreatitis

    International Nuclear Information System (INIS)

    Perfusion computed tomography (P-CT) is now available for the analysis of pancreatic blood flow. The aim of this study was to clarify pancreatic blood perfusion in AIP patients and the changes after steroid treatment. Color map imaging of P-CT and pancreatic time CT density curve (TDC) demonstrated that the pancreatic blood flow was attenuated in AIP patients. Pancreatic volumetric blood flow FV values of 11 AIP patients (82.7/min) were significantly lower than those of 12 normal controls (163.5/min, p=0.0006). AIP patients received steroid treatment and were re-examined, of these, 9 patients showed significantly elevated FV values after treatment (76.2/min and 109.8/min, p=0.0391, respectively). However, the changes of the values after the treatment differed in varying degrees among the individuals. P-CT is a useful method for the analysis of the blood flow in pancreatic diseases. (author)

  6. Coordinate Metrology by Traceable Computed Tomography

    DEFF Research Database (Denmark)

    Müller, Pavel

    is a well-established technique for tolerance verification of manufactured parts. Two reference objects for performance characterization of industrial CT systems were developed within the scope of the Ph.D. thesis. Namely, CT ball plate and CT tree, which were further used for identification......X-ray computed tomography (CT) is a measuring technique which has become an important technology in the production environment over the last years. Due to a number of advantages of CT compared to, e.g., coordinate measuring machines (CMMs), CT has been recently spread in the field of manufacturing...... is an important factor for decision making about manufactured parts. However, due to many influences in CT, estimation of the uncertainty is a challenge, also because standardized procedures and guidelines are not available yet. In this thesis, several methods for uncertainty estimation were applied in connection...

  7. Polychromatic phase-contrast computed tomography

    International Nuclear Information System (INIS)

    Polychromatic phase-contrast radiography differs from traditional (absorption-only) radiography in that the method requires at least a partially coherent x-ray source and the resulting images contain information about the phase shifts of x-rays in addition to the traditional absorption information. In a typical embodiment, this effect results in a measurable enhancement in image contrast at the edges of objects. In this study, a phase-contrast imaging system was adapted to allow an object to be imaged at multiple projections, and these projections were used to generate phase-contrast computed tomography images. The images obtained with this technique show edge enhancements surrounding the objects within the image

  8. Data processing device for computed tomography system

    International Nuclear Information System (INIS)

    A data processing device applied to a computed tomography system which examines a living body utilizing radiation of X-rays is disclosed. The X-rays which have penetrated the living body are converted into electric signals in a detecting section. The electric signals are acquired and converted from an analog form into a digital form in a data acquisition section, and then supplied to a matrix data-generating section included in the data processing device. By this matrix data-generating section are generated matrix data which correspond to a plurality of projection data. These matrix data are supplied to a partial sum-producing section. The partial sums respectively corresponding to groups of the matrix data are calculated in this partial sum-producing section and then supplied to an accumulation section. In this accumulation section, the final value corresponding to the total sum of the matrix data is calculated, whereby the calculation for image reconstruction is performed

  9. Advanced proton imaging in computed tomography

    CERN Document Server

    Mattiazzo, S; Giubilato, P; Pantano, D; Pozzobon, N; Snoeys, W; Wyss, J

    2015-01-01

    In recent years the use of hadrons for cancer radiation treatment has grown in importance, and many facilities are currently operational or under construction worldwide. To fully exploit the therapeutic advantages offered by hadron therapy, precise body imaging for accurate beam delivery is decisive. Proton computed tomography (pCT) scanners, currently in their R&D phase, provide the ultimate 3D imaging for hadrons treatment guidance. A key component of a pCT scanner is the detector used to track the protons, which has great impact on the scanner performances and ultimately limits its maximum speed. In this article, a novel proton-tracking detector was presented that would have higher scanning speed, better spatial resolution and lower material budget with respect to present state-of-the-art detectors, leading to enhanced performances. This advancement in performances is achieved by employing the very latest development in monolithic active pixel detectors (to build high granularity, low material budget, ...

  10. Imaging of Cardiac Valves by Computed Tomography

    Directory of Open Access Journals (Sweden)

    Gudrun Feuchtner

    2013-01-01

    Full Text Available This paper describes “how to” examine cardiac valves with computed tomography, the normal, diseased valves, and prosthetic valves. A review of current scientific literature is provided. Firstly, technical basics, “how to” perform and optimize a multislice CT scan and “how to” interpret valves on CT images are outlined. Then, diagnostic imaging of the entire spectrum of specific valvular disease by CT, including prosthetic heart valves, is highlighted. The last part gives a guide “how to” use CT for planning of transcatheter aortic valve implantation (TAVI, an emerging effective treatment option for patients with severe aortic stenosis. A special focus is placed on clinical applications of cardiac CT in the context of valvular disease.

  11. Computed tomography findings of malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Computed tomography (CT) findings were assessed in 7 patients with malignant mesothelioma. CT findings were also reviewed in 9 patients with lung cancer and pleuritis carcinomatosa and in 11 patients with tuberculous pleuritis. Five patients with malignant mesothelioma underwent CT scans twice, on admission and from 1 to 7 months after admission. Tuberculous pleuritis could be distinguished from pleuritis carcinomatosa and malignant mesothelioma by the presence or absence of pleural nodularity and chest wall invasion. Although it was difficult to identify specific CT features clearly distinguishing malignant mesothelioma from pleuritis carcinomatosa, characteristic findings of malignant mesothelioma appeared to include the rapid development and progression of pleural rind and a tendency to spread directly into the chest wall. We divided the pleural into the four regions; upper anterior, upper posterior, lower anterior and lower posterior regions. Pleural changes were more frequently seen in the lower pleural regions than in the upper pleural regions in malignant mesothelioma. (author)

  12. Computed tomography findings in convergent strabismus fixus

    Energy Technology Data Exchange (ETDEWEB)

    Ohta, Michitaka; Iwashige, Hiroyasu; Hayashi, Takao; Maruo, Toshio [Teikyo Univ., Tokyo (Japan). Faculty of Medicine

    1995-08-01

    X-ray computed tomography (CT) of the eyeball and orbit revealed the cause of eye movement disorder in convergent strabismus fixus. The findings suggest that the disease can be diagnosed and treated at an early stage. Twelve cases of progressive esotropia with high myopia and 20 cases with normal visual acuity served as subjects in this study. The CT slice was parallel to the German horizontal plane, and the lens and medial and lateral rectus muscles were scanned. The average axial length of the affected eyes was significantly longer than in normal eyes. In progressive esotropia, the characteristic CT findings are an elongated eyeball, mechanical contact between the eyeball and lateral wall of the orbit, and a downward displacement of the lateral rectus muscle. Thus, it is reasonable to conclude that eye movement disorder in convergent strabismus fixus results from weakness of the lateral rectus muscle which has been displaced downward due to compression of the eyeball against the orbital wall. (author).

  13. Sparse Image Reconstruction in Computed Tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Sauer

    and limitations of sparse reconstruction methods in CT, in particular in a quantitative sense. For example, relations between image properties such as contrast, structure and sparsity, tolerable noise levels, suficient sampling levels, the choice of sparse reconstruction formulation and the achievable image...... quality remain unclear. This is a problem of high practical concern, because the large scale of CT problems makes detailed exploration of the parameter space very time-consuming. Due to the limited quantitative understanding, sparse reconstruction has not yet become the method of choice in practical CT......In recent years, increased focus on the potentially harmful effects of x-ray computed tomography (CT) scans, such as radiation-induced cancer, has motivated research on new low-dose imaging techniques. Sparse image reconstruction methods, as studied for instance in the field of compressed sensing...

  14. PRIMA+: a proton computed tomography apparatus

    International Nuclear Information System (INIS)

    The proton Computed Tomography (pCT) is a medical imaging method, based on the use of proton beams with kinetic energy of the order of 250 MeV, aimed to directly measure the stopping power distribution of tissues thus improving the present accuracy of treatment planning in hadron therapy. A pCT system should be capable to measure tissue electron density with an accuracy better than 1% and a spatial resolution better than 1 mm. The blurring effect due to multiple Coulomb scattering can be mitigated by single proton tracking technique. As a first step towards pCT the PRIMA+ Collaboration built a prototype capable to carry out a single radiography and a tomographic image of a rotating object. This apparatus includes a silicon microstrip tracker to identify the proton trajectory and a YAG:Ce calorimeter to measure the particle residual energy.

  15. Computer tomography of intracranial tumours and hematomas

    International Nuclear Information System (INIS)

    The value of computed tomography (CT) for the diagnosis of intracranial tumors and hematomas was investigated in a retrospective study comprising 220 patients. All C.T.scans are reviewed and described in detail. To assess the diagnostic accuracy, the original interpretation of the C.T.scans was compared with that of conventional neuroradiological and neurophysiological examinations. The aspect on C.T. of the various types of tumors and hematomas proved to vary widely and specific features were seldom seen. This holds particularly for the malignant tumors. Benign tumors such as meningeomas, adenomas and neurilemmomas showed a rather easily identifiable and almost identical picture of the C.T.scan, and diagnosis had to be based mainly on differences in localization. The hematomas, with the exception of the older intracerebral ones, showed the most characteristic C.T.abnormalities. (Auth.)

  16. Radiation Protection in Paediatric Computed Tomography

    International Nuclear Information System (INIS)

    The number of examinations with radiation exposure has been increasing mainly due to advances in computed tomography (CT) technology, with a rapid expansion of CT utilization. Annually, 3.6 billion diagnostic and medical and dental examinations involving radiation are performed worldwide. The contribution of CT to collective dose due to medical X rays is up to 47–59%. A 2009 report of the National Council on Radiation Protection and Measurements (NCRP) estimates that 8–10% of CT examinations in the United States of America are performed on children; the growth in CT utilization is higher in the paediatric than adult population in the USA; and there is a particularly pronounced rise in adolescents undergoing chest CT in the emergency department setting for suspected pulmonary embolism or trauma. The reasons for the growing incidence of CT are new indications for CT with the advent of multidetector CT, overcautious ordering related to medico-legal problems and probably financial incentive systems

  17. Radiation Protection of Patients in Computed Tomography

    International Nuclear Information System (INIS)

    The use of radiation for medical diagnostic examinations contributes over 95% of human-made radiation exposure and is only exceeded by natural background as a source of exposure to the world’s population. In fact, for several developed countries, the increased use of high dose X ray technology, in particular, computed tomography (CT), has resulted in a situation in which the annual collective and per capita doses of ionizing radiation due to diagnostic radiology have exceeded those from natural background radiation. In light of this marked increase in worldwide collective effective dose from medical diagnostic procedures, and with CT scans accounting for half of this, there is great emphasis on the subject of radiation protection of patients in CT

  18. Myocardial hypoperfusion on conventional contrast computed tomography.

    Science.gov (United States)

    Ching, Shing; Chung, Tak Shun

    2015-10-01

    Non–electrocardiogram (ECG)–gated contrast computed tomography (CT) is commonly performed to exclude aortic dissection in chest pain patients. Besides evaluating the aorta for dissection flap, attention should be paid to the myocardium for areas of hypoenhancement that may suggest ischemia. Current models of multidetector CT enable assessment of myocardial perfusion with minimal motion artifact even without ECG gating. Transmural hypoenhancement with preserved wall thickness in a coronary distribution is highly specific for acute myocardial infarction. We report 2 cases of acute chest pain with initial nondiagnostic studies that underwent CT aortogram to exclude dissection. Instead, the CT showed myocardial hypoenhancement in left anterior descending artery territory. Myocardial hypoenhancement occurred before ST-segment elevation on ECG, suggesting that recognition of this important finding may lead to earlier revascularization decisions. PMID:26321167

  19. Neutron stimulated emission computed tomography: Background corrections

    Energy Technology Data Exchange (ETDEWEB)

    Floyd, Carey E. [Dept. of Biomedical Engineering, Duke University, Durham, NC 27708 (United States)]|[Duke Advanced Imaging Laboratories, Dept. of Radiology, Duke University, Durham, NC 27708 (United States)]|[Medical Physics Graduate Program, Duke University, Durham, NC 27708 (United States); Sharma, Amy C. [Dept. of Biomedical Engineering, Duke University, Durham, NC 27708 (United States)]|[Duke Advanced Imaging Laboratories, Dept. of Radiology, Duke University, Durham, NC 27708 (United States); E-mail: anc4@duke.edu; Bender, Janelle E.; Kapadia, Anuj J.; Xia, Jessie Q. [Dept. of Biomedical Engineering, Duke University, Durham, NC 27708 (United States)]|[Duke Advanced Imaging Laboratories, Dept. of Radiology, Duke University, Durham, NC 27708 (United States); Harrawood, Brian P. [Duke Advanced Imaging Laboratories, Dept. of Radiology, Duke University, Durham, NC 27708 (United States); Tourassi, Georgia D. [Duke Advanced Imaging Laboratories, Dept. of Radiology, Duke University, Durham, NC 27708 (United States); Lo, Joseph Y. [Dept. of Biomedical Engineering, Duke University, Durham, NC 27708 (United States)]|[Duke Advanced Imaging Laboratories, Dept. of Radiology, Duke University, Durham, NC 27708 (United States)]|[Medical Physics Graduate Program, Duke University, Durham, NC 27708 (United States); Kiser, Matthew R.; Crowell, Alexander S. [Dept. of Physics and Triangle Universities Nuclear Laboratory, Duke University, Durham, NC 27708 (United States); Pedroni, Ronald S. [North Carolina A and T State University, Greensboro, NC (United States); Macri, Robert A. [Lawrence Livermore National Laboratory, Livermore, CA (United States); Tajima, Shigeyuki [Dept. of Physics, University of Virginia, Charlottesville, VA (United States); Howell, Calvin R. [Medical Physics Graduate Program, Duke University, Durham, NC 27708 (United States)]|[Dept. of Physics and Triangle Universities Nuclear Laboratory, Duke University, Durham, NC 27708 (United States)

    2007-01-15

    Neutron stimulated emission computed tomography (NSECT) is an imaging technique that provides an in-vivo tomographic spectroscopic image of the distribution of elements in a body. To achieve this, a neutron beam illuminates the body. Nuclei in the body along the path of the beam are stimulated by inelastic scattering of the neutrons in the beam and emit characteristic gamma photons whose unique energy identifies the element. The emitted gammas are collected in a spectrometer and form a projection intensity for each spectral line at the projection orientation of the neutron beam. Rotating and translating either the body or the beam will allow a tomographic projection set to be acquired. Images are reconstructed to represent the spatial distribution of elements in the body. Critical to this process is the appropriate removal of background gamma events from the spectrum. Here we demonstrate the equivalence of two background correction techniques and discuss the appropriate application of each.

  20. Ultra-high resolution computed tomography imaging

    Energy Technology Data Exchange (ETDEWEB)

    Paulus, Michael J. (Knoxville, TN); Sari-Sarraf, Hamed (Knoxville, TN); Tobin, Jr., Kenneth William (Harriman, TN); Gleason, Shaun S. (Knoxville, TN); Thomas, Jr., Clarence E. (Knoxville, TN)

    2002-01-01

    A method for ultra-high resolution computed tomography imaging, comprising the steps of: focusing a high energy particle beam, for example x-rays or gamma-rays, onto a target object; acquiring a 2-dimensional projection data set representative of the target object; generating a corrected projection data set by applying a deconvolution algorithm, having an experimentally determined a transfer function, to the 2-dimensional data set; storing the corrected projection data set; incrementally rotating the target object through an angle of approximately 180.degree., and after each the incremental rotation, repeating the radiating, acquiring, generating and storing steps; and, after the rotating step, applying a cone-beam algorithm, for example a modified tomographic reconstruction algorithm, to the corrected projection data sets to generate a 3-dimensional image. The size of the spot focus of the beam is reduced to not greater than approximately 1 micron, and even to not greater than approximately 0.5 microns.

  1. Computed tomography and magnetic resonance findings in lipoid pneumonia.

    OpenAIRE

    Bréchot, J M; Buy, J N; Laaban, J P; Rochemaure, J

    1991-01-01

    A case of exogenous lipoid pneumonia was documented by computed tomography and magnetic resonance imaging. Although strongly suggesting the presence of fat on T1 weighted images, magnetic resonance does not produce images specific for this condition. Computed tomography is the best imaging modality for its diagnosis.

  2. Diagnosis of lumbar disc hernia with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizumi, Atsuro; Ohira, Nobuhiro; Ojima, Tadashi; Oshida, Midori; Horaguchi, Mitsuru (Tohoku Rosai Hospital, Sendai (Japan))

    1982-07-01

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed.

  3. The role of computed tomography in the laryngeal injury

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Hoon Sik [Capital Armed Forces General Hospital, Seongnam (Korea, Republic of)

    1984-03-15

    Computed tomography of the larynx represents a major advance in laryngology. Even in severe injury the larynx can be examined easily and conveniently by CT at the same time as the brain and facial structures without moving the patient, who need only lie down and breathe quietly during the study. Computed tomography permitted a much more detailed appraisal of laryngeal dysfunction in patients with blunt laryngeal trauma (3 cases) and strangulation injury (2 cases). Computed tomography of the larynx undoubtedly played a determinant role in patient management. Computed tomography was helpful in evaluating the laryngeal cartilages and deep spaces of the larynx which was difficult to examine by the laryngoscope. Follow-up computed tomography made it possible to evaluate the postoperative results.

  4. Terahertz Computed Tomography of NASA Thermal Protection System Materials

    Science.gov (United States)

    Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.

    2011-01-01

    A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

  5. Computed tomography of traumatic intracranial lesions

    International Nuclear Information System (INIS)

    The cranial computed tomography (CT) is a new radiological technique with which, for the first time, minimal differences an attenuation by intracranial soft tissue can be measured exactly. The basic physical principles of computed tomography have been extensively presented by Hounsfield (1973). It is well established that the attenuation of extravasated blood measures between 35 and 45 Hounsfield units. Therefore no difficulty should be encountered in the recognition and diagnosis of extra-axial hematoma and cerebral contusion since the density of the brain parenchyma never measures more than 25 units. As the constant increase in high velocity accidents and violence, the problem of acute head injury is one of the matters of great importance in today's medical practice. Therefore it is very important to figure out the method that would allow us to diagnose easily and precisely the effects of trauma upon the brain in order to institute the proper treatment at the earliest possible moment. Computed tomography allows us to make a diagnosis quickly and in a non-invasive manner. The CT scan was carried out on 310 head trauma cases in the department of radiology, St. Mary's and Kang Nam St. Mary's Hospital, Catholic Medical College, for 16 months from June 1979 to October 1980. All the scans were obtained with the Hitachi CT-H2 scanner and the scans were repeated following intravenous injection of high dose of contrast media (roughly 1.8 cc per kg body weight of 60% Conray). We have reviewed the CT scans of 310 patients got acute head injury in order to assess the location of brain lesions, the relationship between the CT densities of hematomas and their stage, the shape and mass effect of the extra-axial hematomas, and the effect of contrast enhancement. The results were as follows: 1. Of all 310 cases of the head injuries, epidural hematoma was 13.5%, subdural hematoma was 8.7%, subdural hygroma was 10%, cerebral contusion was 39%, hydrocephalus and atrophy was 3.9% and

  6. Giant hepatic cavernous hemangioma. Findings on computed helical tomography

    International Nuclear Information System (INIS)

    Objective: To describe computed helical tomography characteristics of the giant hepatic cavernous hemangioma. Method: During five years, we evaluated 21 patients with 21 giant hepatic cavernous hemangiomas with computed helical and multislice tomography. We included 18 women (86%) and 3 men (14%) with a mean age of 45 years. Results: The mean size of hemangiomas was 10.4 cm. Non enhanced computed tomography Showed 21 hemangiomas with lower density than adjacent hepatic parenchyma , all hemangiomas showed a central cleft area with low density. None hemangioma showed calcifications neither internal septa. In enhanced helical tomography all lesions demonstrated a globular, peripheral enhancing pattern with centripetal filling that begin in the arterial phase and continued in portal and delayed phases. None of the lesions showed complete filling. Conclusion: giant hepatic cavernous hemangiomas showed low attenuation in non enhanced computed tomography. central cleft area was very frequently seen. The enhancement pattern is characteristic, starting at the periphery with centripetal filling but it was never complete.

  7. Reproducibility in the assessment of acute pancreatitis with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Freire Filho, Edison de Oliveira; Vieira, Renata La Rocca; Yamada, Andre Fukunishi; Shigueoka, David Carlos; Bekhor, Daniel; Freire, Maxime Figueiredo de Oliveira; Ajzen, Sergio; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of Imaging Diagnosis]. E-mail: eofilho@ig.com.br; eoffilho@uol.com.br

    2007-11-15

    Objective: To evaluate the reproducibility of unenhanced and contrast-enhanced computed tomography in the assessment of patients with acute pancreatitis. Materials and methods: Fifty-one unenhanced and contrast-enhanced abdominal computed tomography studies of patients with acute pancreatitis were blindly reviewed by two radiologists (observers 1 and 2). The morphological index was separately calculated for unenhanced and contrast-enhanced computed tomography and the disease severity index was established. Intraobserver and interobserver reproducibility of computed tomography was measured by means of the kappa index ({kappa}). Results: Interobserver agreement was {kappa} 0.666, 0.705, 0.648, 0.547 and 0.631, respectively for unenhanced and contrast-enhanced morphological index, presence of pancreatic necrosis, pancreatic necrosis extension, and disease severity index. Intraobserver agreement (observers 1 and 2, respectively) was {kappa} = 0.796 and 0.732 for unenhanced morphological index; {kappa} 0.725 and 0.802 for contrast- enhanced morphological index; {kappa} = 0.674 and 0.849 for presence of pancreatic necrosis; {kappa} = 0.606 and 0.770 for pancreatic necrosis extension; and {kappa} = 0.801 and 0.687 for disease severity index at computed tomography. Conclusion: Computed tomography for determination of morphological index and disease severity index in the staging of acute pancreatitis is a quite reproducible method. The absence of contrast- enhancement does not affect the computed tomography morphological index reproducibility. (author)

  8. Analysis of the computed tomography in the acute abdomen

    International Nuclear Information System (INIS)

    Introduction: This study tends to test the capacity of the computed tomography in assist in the diagnosis and the approach of the acute abdomen. Material and method: This is a longitudinal and prospective study, in which were analyzed the patients with the diagnosis of acute abdomen. There were obtained 105 cases of acute abdomen and after the application of the exclusions criteria were included 28 patients in the study. Results: Computed tomography changed the diagnostic hypothesis of the physicians in 50% of the cases (p 0.05), where 78.57% of the patients had surgical indication before computed tomography and 67.86% after computed tomography (p = 0.0546). The index of accurate diagnosis of computed tomography, when compared to the anatomopathologic examination and the final diagnosis, was observed in 82.14% of the cases (p = 0.013). When the analysis was done dividing the patients in surgical and nonsurgical group, were obtained an accuracy of 89.28% (p 0.0001). The difference of 7.2 days of hospitalization (p = 0.003) was obtained compared with the mean of the acute abdomen without use the computed tomography. Conclusion: The computed tomography is correlative with the anatomopathology and has great accuracy in the surgical indication, associated with the capacity of increase the confident index of the physicians, reduces the hospitalization time, reduces the number of surgeries and is cost-effective. (author)

  9. Dedicated breast computed tomography: Basic aspects

    Energy Technology Data Exchange (ETDEWEB)

    Sarno, Antonio; Mettivier, Giovanni, E-mail: mettivier@na.infn.it; Russo, Paolo [Dipartimento di Fisica, Università di Napoli Federico II, Via Cintia, Napoli I-80126, Italy and INFN Sezione di Napoli, Napoli I-80126 (Italy)

    2015-06-15

    X-ray mammography of the compressed breast is well recognized as the “gold standard” for early detection of breast cancer, but its performance is not ideal. One limitation of screening mammography is tissue superposition, particularly for dense breasts. Since 2001, several research groups in the USA and in the European Union have developed computed tomography (CT) systems with digital detector technology dedicated to x-ray imaging of the uncompressed breast (breast CT or BCT) for breast cancer screening and diagnosis. This CT technology—tracing back to initial studies in the 1970s—allows some of the limitations of mammography to be overcome, keeping the levels of radiation dose to the radiosensitive breast glandular tissue similar to that of two-view mammography for the same breast size and composition. This paper presents an evaluation of the research efforts carried out in the invention, development, and improvement of BCT with dedicated scanners with state-of-the-art technology, including initial steps toward commercialization, after more than a decade of R and D in the laboratory and/or in the clinic. The intended focus here is on the technological/engineering aspects of BCT and on outlining advantages and limitations as reported in the related literature. Prospects for future research in this field are discussed.

  10. Computed tomography studies on patients with mucopolysaccharidoses

    International Nuclear Information System (INIS)

    The appearances on computed tomography (CT) in eight patients with mucopolysaccharidosis Type I, two with mucopolysaccharidosis Type II and two with mucopolysaccharidosis Type IIIB are presented. Reference is also made to two further cases in which the CT showed special features. Follow-up scans were obtained to assess the evolution of the changes. The place of CT in the diagnosis of complications due to thecal involvement is examined. The density of grey matter on the CT scans was similar to that of normal brain. Inhaled xenon did not produce any special enhancement which could be helpful in assessing the degree of the mucopolysaccharide deposition within cerebral cells. Symmetrical low attenuation in the white matter was a very common finding. This work has shown that the stage in the evolution of the mucopolysaccharidoses at which hydrocephalus develops as a complication is highly variable and CSF diversion procedures are sometimes indicated to improve the quality of the patients' lives. These indications are briefly discussed. We consider that CT is essential for the adequate appraisal of these patients and to identify some treatable complications. (orig./MG)

  11. Radiation Doses from Computed tomography in Iraq

    International Nuclear Information System (INIS)

    Radiation doses to Patient during CT scanner and the radiological risk are significant. Patient dose survey has been conducted to investigate the Iraq patient radiation doses received in CT scanners in order to established reference dose levels. These doses are Entrance Surface Dose (ESD),computed tomography dose index(CTDI)), and dose length product (DLP). Two CT scanner were investigated in this study were, Siemens Somatom Plus 4, located in at medical city of Baghdad, and Philips, Optimus located in privet hospital at Baghdad. ESD were measured by TLD and Dosimax ionization chamber for head, chest, and abdomen for both sex and different weights. The TLD results were higher than that measured with Dosimax due to scattered radiation .The scattering factor which is the ratio between dose measured by TLD and that measured by ionization chamber range between (1.14-1.34) compare to international measurement which is range between (1.1-1.5).The (ESD) measured by the two methods were agree well after the subtraction of scattering dose, and have compered with original research. Dose profile were measured using array of TLD chips shows that its full width at half maximum is(7.99 mm) approximately equal the slice thickness(8 mm). Our results compare with reference level at U.K, European Guidelines and

  12. Quantitative investigations of megavoltage computed tomography

    Science.gov (United States)

    Rogers, Myron; Kerr, Andrew; Salomons, Greg; Schreiner, L. John

    2005-04-01

    Megavoltage computed tomography (MVCT) has been an active area of research and development in image guided radiation therapy. We have been investigating a particular implementation of MVCT in conjunction with studies of the potential for tomotherapy with a Cobalt-60 radiation source. In this paper, we present results comparing MVCT using a Co-60 source and a 4 MV linear accelerator to conventional kVCT imaging. The Co-60 and linac MVCT measurements were obtained with a first generation benchtop CT imager; the KVCT measurements were obtained using a Philips AcQSim CT Simulator). Phantoms containing various inserts ranging in density from air, through lung, soft tissue and bone equivalent materials and extending to high atomic number metals were imaged with the three modalities. The results enable characterization of image artifacts, CT number linearity and beam hardening. The MVCT images have sufficient contrast that soft tissue regions with 2.8% difference in electron density can be visualized. In MVCT, a linear relationship between CT numbers and electron densities extends to materials with Z ~ 60. In the 4MV CT imaging there is a position dependence of the CT numbers within a uniform water phantom, which is absent in Co-60 CT images, indicating the presence of beam hardening artifacts in the linac MVCT images. The differences between kVCT and MVCT will be discussed considering the variation of the photon interactions dominating the images. Our investigations indicate that MVCT has properties that may potentially extend its utility beyond radiation therapy.

  13. Radiation doses from computed tomography in Australia

    International Nuclear Information System (INIS)

    Recent surveys in various countries have shown that computed tomography (CT) is a significant and growing contributor to the radiation dose from diagnostic radiology. Australia, with 332 CT scanners (18 per million people), is well endowed with CT equipment compared to European countries (6 to 13 per million people). Only Japan, with 8500 units (78 per million people), has a significantly higher proportion of CT scanners. In view of this, a survey of CT facilities, frequency of examinations, techniques and patient doses has been performed in Australia. It is estimated that there are 1 million CT examinations in Australia each year, resulting in a collective effective dose of 7000 Sv and a per caput dose of 0.39 mSv. This per caput dose is much larger than found in earlier studies in the UK and New Zealand but is less than 0.48 mSv in Japan. Using the ICRP risk factors, radiation doses from CT could be inducing about 280 fatal cancers per year in Australia. CT is therefore a significant, if not the major, single contributor to radiation doses and possible risk from diagnostic radiology. (authors)

  14. Computed tomography findings in fibrosing mediastinitis

    Energy Technology Data Exchange (ETDEWEB)

    Devaraj, A. [Departments of Radiology, Royal Brompton Hospital, London (United Kingdom)]. E-mail: a.devaraj@rbht.nhs.uk; Griffin, N. [Department of Radiology, Chelsea and Westminster Hospital, London (United Kingdom); Nicholson, A.G. [Department of Histopathology, Royal Brompton Hospital, London (United Kingdom); Padley, S.P.G. [Departments of Radiology, Royal Brompton Hospital, London (United Kingdom)

    2007-08-15

    Aim: To describe the CT features of fibrosing mediastinitis. Materials and methods: The clinical notes, histology, and CT images from 12 patients with fibrosing mediastinitis were reviewed. Clinical data regarding the presentation and suspected aetiology were correlated with location of mediastinal disease, calcification, effect on mediastinal structures, and additional pulmonary findings on computed tomography (CT). Results: The mean age was 40.5 years, with seven female and five male patients. The most common presenting symptom was shortness of breath. Fibrosing mediastinitis diffusely infiltrated the mediastinum in five patients and was localized in seven. Calcification was present in two cases. Eleven of 12 cases had narrowing of mediastinal structures, including five with pulmonary artery narrowing, five with superior vena cava obstruction, four with bronchial narrowing, three with tracheal narrowing, and one with narrowing of the pulmonary vein. The disease was considered idiopathic in seven cases with a demonstrable aetiology in five cases. Eight out of 12 patients had additional pulmonary findings, including all patients with a known aetiology. Conclusions: In the present series of patients, fibrosing mediastinitis more commonly presented as a localized mediastinal mass than as diffuse mediastinal disease, with the anterior mediastinal compartment most frequently involved. Most cases were idiopathic compared with the majority of previous cases at this institution being ascribed to tuberculosis. There is a high incidence of concomitant pulmonary findings, in particular when an identifiable aetiology is present. Obstruction of vital structures frequently gives rise to complications.

  15. Intraperitoneal tuberculous abscess: computed tomography features

    Institute of Scientific and Technical Information of China (English)

    Peng; Dong; Jing-Jing; Chen; Xi-Zhen; Wang; Ya-Qin; Wang

    2015-01-01

    AIM: To evaluate the computed tomography(CT) features of intraperitoneal tuberculous abscess(IPTA). METHODS: Eight patients with IPTA confirmed by pathology were analyzed retrospectively. The clinical symptoms, medical images, and surgical findings were evaluated. Involvement of the intestine, peritoneum, viscera, and lymph nodes was also assessed. RESULTS: All 8 patients had a history of abdominal discomfort for 1 to 6 mo. Physical examination revealed a palpable abdominal mass in 6 patients. Three patients had no evidence of pulmonary tuberculosis(TB). All IPTAs(11 abscesses) were seen as a multiseptated, peripherally enhanced, hypodense mass with enlarged, rim-enhanced lymph nodes. The largest abscess diameter ranged from 4.5 cm to 12.2 cm. CT showed 2 types of IPTA: Lymph node fusion and encapsulation. Of the 8 patients, one had liver tuberculosis and one had splenic and ovarian tuberculosis. Two cases showed involvement of the terminal ileum and ileocecal junction. Ascites were found in 4 cases. Three patients had peritonitis and mesenteritis. Three patients showed involvement of the omentum. Three patients had histological evidence of caseating granuloma, and 5 had histological evidence of acid-fast bacilli. CONCLUSION: CT is crucial in the detection and characterization of IPTA. Certain CT findings are necessary for correct diagnosis.

  16. Application of computed tomography in paleoanthropological research

    Institute of Scientific and Technical Information of China (English)

    Xiujie Wu; Lynne A.Schepartz

    2009-01-01

    Hominin fossils are the most important materials for exploring questions about human origins and evolution. Because human fossils are very rare, it is impossible to use highly destructive techniques in order to study their morphology. Traditional analyses can only rely on the information gained from the study of the external morphology of specimens, and these approaches limited the study of human evolution. The application of computed tomography (CT) has facilitated major developments in paleoanthropology. To date, few studies on Chinese hominin fossils have used CT scanning methodology, but this is rapidly changing. In order to better understand the appli-cation of CT methodology in paleoanthropology, we review the applications of CT scanning on hominin fossils throughout the world.Studies examined include virtual fossil reconstruction, the use of endocasts to elucidate brain morphology, biomechanical analyses of bone distribution, imaging of mummies and research on early human health, and skeletal and dental microanatomical research.2009 National Natural Science Foundation of China and Chinese Academy of Sciences. Published by Elsevier Limited and Science in China Press. All rights reserved.

  17. A Detector for Proton Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blazey, G.; et al.

    2013-12-06

    Radiation therapy is a widely recognized treatment for cancer. Energetic protons have distinct features that set them apart from photons and make them desirable for cancer therapy as well as medical imaging. The clinical interest in heavy ion therapy is due to the fact that ions deposit almost all of their energy in a sharp peak – the Bragg peak- at the very end of their path. Proton beams can be used to precisely localize a tumor and deliver an exact dose to the tumor with small doses to the surrounding tissue. Proton computed tomography (pCT) provides direct information on the location on the target tumor, and avoids position uncertainty caused by treatment planning based on imaging with X-ray CT. The pCT project goal is to measure and reconstruct the proton relative stopping power distribution directly in situ. To ensure the full advantage of cancer treatment with 200 MeV proton beams, pCT must be realized.

  18. Dose profile in computed tomography chest scan

    International Nuclear Information System (INIS)

    For the optimization of the patient dose in computed tomography (CT), the Brazilian legislation only established the diagnostic reference levels (DRL's) in terms of Multiple Scan Average Dose (MSAD) in a typical adult as a parameter of quality control of CT scanners. Conformity to the DRL's can be verified by measuring the dose distribution in CT scans and MSAD determination. An analysis of the quality of CT scans of the metropolitan region of Belo Horizonte is necessary by conducting pertinent tests to the study that are presented in the ANVISA (National Agency of Sanitary Vigilance) Guide. The purpose of this study is to investigate, in a chest scan, the variation of dose in CT. To measure the dose profile are used lithium fluoride thermoluminescent dosimeters (TLD-100 Rod) distributed in cylinders positioned in peripheral and central regions of a phantom of polymethylmethacrylate (PMMA). The data obtained allow us to observe the variation of the dose profile inside the phantom. The peripheral region shows higher dose values than the central region. The longitudinal variation can be observed and the maximum dose was recorded at the edges of the phantom (41,58±5,10) mGy at the midpoint of the longitudinal axis. The results will contribute to disseminate the proper procedure and optimize the dosimetry and the tests of quality control in CT, as well as make a critical analysis of the DRL's. (author)

  19. Portable Digital Radiography and Computed Tomography Manual

    Energy Technology Data Exchange (ETDEWEB)

    2007-11-01

    This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

  20. Computed tomography in acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Loevblad, Karl-Olof [HUG-Geneva University Hospital, Geneva University Medical School, Department of Neuroradiology, Department of Imaging and Medical Informatics, Geneva (Switzerland); Baird, Alison E. [SUNY Downstate Medical Center, Cerebrovascular Disease and Stroke, 450 Clarkson Avenue, Box 1213, Brooklyn, NY (United States)

    2010-03-15

    Stroke remains the third most important cause of mortality in industrialized countries; this has prompted research for improvements in both diagnostic and therapeutic strategies for patients with signs of acute cerebral ischemia. Over the last decade, there has been a parallel in progress in techniques in both diagnostic and therapeutic options. While previously only used for excluding hemorrhage, imaging now has the possibility to detect ischemia, vascular occlusion, as well as detect tissue at risk in one setting. It should also allow to monitor treatment and predict/exclude therapeutic complications. Parallel to advances in magnetic resonance imaging of stroke, computed tomography has improved immensely over the last decade due to the development of CT scanners that are faster and that allow to acquire studies such as CT perfusion or CT angiography in a reliable way. CT can detect many signs that might help us detect impending signs of massive infarction, but we still lack the experience to use these alone to prevent a patient from benefitting from possible therapy. (orig.)

  1. Computed tomography and magnetic resonance colonography

    International Nuclear Information System (INIS)

    Colon cancer is the second leading cause of cancer death in the western world. Adenomatous colorectal polyps, which are found in 30-50% of Americans more than 50 years old, are recognized as important precursors of malignancy. Probably most of the invasive colon carcinomas arise from polyps. For this reason an early detection of these polyps and their complete removal is a recognized strategy for the prevention of colon cancer. So far no single method for an early diagnois of colon polyps or colon cancer offers high sensitivity and specificity along with low cost and good patient accccf Endo-opic colonoscopy allows the accurate detection of very small lesions and has since almost completely replaced fluooscopy. Cross-sectional imaging techniques, including magnetic resonance imaging (MRI) and computed tomography (CT), are increasingly being considered imaging modalities for the detection of colorectal polyps. CT and MR colonography are new techniques for imaging of the colon. In symptomatic patients, these new techniques show promising results for the detection of polyps equal to or larger than 1 cm in diameter. (author)

  2. Computed tomography imaging and angiography - principles.

    Science.gov (United States)

    Kamalian, Shervin; Lev, Michael H; Gupta, Rajiv

    2016-01-01

    The evaluation of patients with diverse neurologic disorders was forever changed in the summer of 1973, when the first commercial computed tomography (CT) scanners were introduced. Until then, the detection and characterization of intracranial or spinal lesions could only be inferred by limited spatial resolution radioisotope scans, or by the patterns of tissue and vascular displacement on invasive pneumoencaphalography and direct carotid puncture catheter arteriography. Even the earliest-generation CT scanners - which required tens of minutes for the acquisition and reconstruction of low-resolution images (128×128 matrix) - could, based on density, noninvasively distinguish infarct, hemorrhage, and other mass lesions with unprecedented accuracy. Iodinated, intravenous contrast added further sensitivity and specificity in regions of blood-brain barrier breakdown. The advent of rapid multidetector row CT scanning in the early 1990s created renewed enthusiasm for CT, with CT angiography largely replacing direct catheter angiography. More recently, iterative reconstruction postprocessing techniques have made possible high spatial resolution, reduced noise, very low radiation dose CT scanning. The speed, spatial resolution, contrast resolution, and low radiation dose capability of present-day scanners have also facilitated dual-energy imaging which, like magnetic resonance imaging, for the first time, has allowed tissue-specific CT imaging characterization of intracranial pathology. PMID:27432657

  3. REVIEW: X-ray computed tomography

    Science.gov (United States)

    Kalender, Willi A.

    2006-07-01

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention.

  4. Computed tomography experiments of Pantex high explosives

    Science.gov (United States)

    Perkins, D. E.; Martz, H. E.; Hester, L. O.; Sobczak, G.; Pratt, C. L.

    1992-04-01

    X-ray computed tomography is an advanced imaging technique which provide three-dimensional nondestructive characterization of materials, components and assemblies. The CT Project group at Lawrence Livermore National Laboratory (LLNL) and the Pantex Plant are cooperating to examine the use of CT technology to inspect and characterize high-explosives pressings (e.g., PBX-9502, LX-10-2). High-explosives pressings manufactured by Pantex must be characterized prior to assembling into weapons systems; a nondestructive examination of all assembly parts would be preferable to the current sampling and destructive testing. The earlier in the processing cycle this can be done the more cost effective it will be. We have performed experiments that show that this characterization can be performed at the pressed billet stage using CT. We have detected 2-mm inclusions in a 15-cm diameter billet and 3.5-mm voids in a 20-cm diameter billet. Based on these results we show calculations that can be used to design production CT systems for characterization of high-explosives.

  5. Perfusion computed tomography in renal cell carcinoma

    Institute of Scientific and Technical Information of China (English)

    Chandan; J; Das; Usha; Thingujam; Ananya; Panda; Sanjay; Sharma; Arun; Kumar; Gupta

    2015-01-01

    Various imaging modalities are available for the diagnosis, staging and response evaluation of patients with renal cell carcinoma(RCC). While contrast enhanced computed tomography(CT) is used as the standard of imaging for size, morphological evaluation and response assessment in RCC, a new functional imaging technique like perfusion CT(p CT), goes down to the molecular level and provides new perspectives in imaging of RCC. p CT depicts regional tumor perfusion and vascular permeability which are indirect parameters of tumor angiogenesis and thereby provides vital information regarding tumor microenvironment. Also response evaluation using p CT may predate the size criteria used in Response Evaluation Criteria in Solid Tumors, as changes in the perfusion occurs earlier following tissue kinase inhibitors before any actual change in size. This may potentially help in predicting prognosis, better selection of therapy and more accurate and better response evaluation in patients with RCC. This article describes the techniques and role of p CT in staging and response assessment in patients with RCCs.

  6. Radiation doses from computed tomography in Australia

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, J.E.M.; Tingey, D.R.C

    1997-11-01

    Recent surveys in various countries have shown that computed tomography (CT) is a significant and growing contributor to the radiation dose from diagnostic radiology. Australia, with 332 CT scanners (18 per million people), is well endowed with CT equipment compared to European countries (6 to 13 per million people). Only Japan, with 8500 units (78 per million people), has a significantly higher proportion of CT scanners. In view of this, a survey of CT facilities, frequency of examinations, techniques and patient doses has been performed in Australia. It is estimated that there are 1 million CT examinations in Australia each year, resulting in a collective effective dose of 7000 Sv and a per caput dose of 0.39 mSv. This per caput dose is much larger than found in earlier studies in the UK and New Zealand but is less than 0.48 mSv in Japan. Using the ICRP risk factors, radiation doses from CT could be inducing about 280 fatal cancers per year in Australia. CT is therefore a significant, if not the major, single contributor to radiation doses and possible risk from diagnostic radiology. (authors) 28 refs., 11 tabs., 10 figs.

  7. Computed tomography findings in pancreas divisum

    International Nuclear Information System (INIS)

    In 29 patients with abdominal pain the diagnosis of pancreas divisum (PD) was verified by endoscopic retrograde pancreatography (EPR) via both the major and the minor papilla. Computed tomography (CT) was done in all patients to evaluate contour, volume, antero-posterior diameters and attenuation values of the gland in comparison with a normal reference series. Also, the validity of the CT grading of pancreatitis was assessed in comparison with ERP grading. Patients with PD had an increased cranio-caudal diameter of the pancreatic head (p<0.001). Further, the main pancreatic duct was visualized more often in patients with PD (p<0.01), who also had an increasing frequency of pancreatic calcifications (p<0.05). Otherwise there were no differences compared with the normal series. The observed reduction in the volume of the gland in patients with marked pancreatitis at ERP seemingly reflected the severity of inflammation. No cleavage between the dorsal and ventral anlage was identified. CT was found to be too unspecific to be of any use in grading of pancreatitis. In conclusion, CT findings in patients with PD are sparse, unspecific and preferably a reflection of pancreatitis, if present. ERP remains the ''gold standard'' for the diagnosis. (orig.)

  8. Relevance of computed tomography in gynecological tumors

    Energy Technology Data Exchange (ETDEWEB)

    Hagemann, J.R.; Hagemann, J.

    1983-11-01

    1. Abdominal CT examination is the method of choice when examining ovarial tumours. 2. Abdominal CT is redundant in the early stages of carcinoma of the collum and if the carcinoma has penetrated into the vagina. 3. In advanced stages of carcinoma of the collum, CT enables accurate staging. CT is at least equal in relevance to gynecological examination in respect of assessment of parametraneous infiltration. Distant metastases, as well as complications of the efferent urinary tract can be visualized. In view of this, the following procedure appears meaningful in advanced carcinoma of the collum: First of all, gynecological examination is performed without anaesthesia to confirm the findings in the regions of the portio and vagina; as far as possible, the existence of the central parametraneous infiltrations is confirmed. For the purpose of further staging of the parametraneous infiltration, as well as of the paraaortal lymphomas and possible metastases, as well as for the purpose of excluding hydronephrosis, computed tomography is performed. This avoids burdening the patient with an examination under anaesthesia, and it also avoids invasive examination methods, such as urography and lymphography.

  9. Relevance of computed tomography in gynaecological tumors

    International Nuclear Information System (INIS)

    1. Abdominal CT examination is the method of choice when examining ovarial tumours. 2. Abdominal CT is redundant in the early stages of carcinoma of the collum and if the carcinoma has penetrated into the vagina. 3. In advanced stages of carcinoma of the collum, CT enables accurate staging. CT is at least equal in relevance to gynaecological examination in respect of assessment of parametraneous infiltration. Distant metastases, as well as complications of the efferent urinary tract can be visualized. In view of this, the following procedure appears meaningful in advanced carcinoma of the collum: First of all, gynaecological examination is performed without anaesthesia to confirm the findings in the regions of the portio and vagina; as far as possible, the existence of the central parametraneous infiltrations is confirmed. For the purpose of further staging of the parametraneous infiltration, as well as of the paraaortal lymphomas and possible metastases, as well as for the purpose of excluding hydronephrosis, computed tomography is performed. This avoids burdening the patient with an examination under anaesthesia, and it also avoids invasive examination methods, such as urography and lymphography. (orig.)

  10. Dynamic X-ray computed tomography

    International Nuclear Information System (INIS)

    Paper Dynamic computed tomography (CT) imaging aims at reconstructing image sequences where the dynamic nature of the living human body is of primary interest. Main concerned applications are image-guided interventional procedures, functional studies and cardiac imaging. The introduction of ultra-fast rotating gantries along with multi-row detectors and in near future area detectors allows a huge progress toward the imaging of moving organs with low-contrast resolution. This paper gives an overview of the different concepts used in dynamic CT. A new reconstruction algorithm based on a voxel-specific dynamic evolution compensation is also presented. It provides four-dimensional image sequences with accurate spatio-temporal information, where each frame is reconstructed using a long-scan acquisition mode on several half-turns. In the same time, this technique permits to reduce the dose delivered per rotation while keeping the same signal to noise ratio for every frame using an adaptive motion-compensated temporal averaging. Results are illustrated on simulated data. (authors)

  11. Ruptured ectopic pregnancy diagnosed with computed tomography

    International Nuclear Information System (INIS)

    The rupture of ectopic pregnancy (EP) still remains the primary and direct cause of death in the first trimester of pregnancy. Ultrasonography is known to be a modality of choice in EP diagnostics. We found a severe discrepancy between the frequency of ectopic pregnancies (EP) and the number of available computed tomography (CT) examinations. A 29-year-old woman was admitted to the emergency department with a history of abdominal pain, nausea, vomiting and collapse. Sonographic findings of a suspected EP were unclear. Moreover, not all features of intrauterine pregnancy were present. Due to the patient’s life-threatening condition, an emergency multi-slice CT with MPR and VRT reconstructions was performed, revealing symptoms of a ruptured EP. In the right adnexal area, a well-vascularized, solid-cystic abnormal mass lesion was found. Intraperitoneal hemorrhage was confirmed intraoperatively, and the right fallopian tube with a tubal EP was resected. In the surgery in situ, as well as in the pathological examination of the tumor mass, a human embryo of approximately 1.5 cm in length (beginning of the 8th week of gestation) was found. Although ultrasonography still remains the first-line imaging examination in EP diagnostics, sometimes the findings of suspected EPs are unclear and not sufficient. The rupture of EP, with serious bleeding and symptoms of shock, may require an emergent pelvic and abdominal CT inspection. A clear correlation was found between the macroscopic CT images and the intraoperatively sampled material

  12. Computed Tomography Following Body Stuffing Heroin

    Directory of Open Access Journals (Sweden)

    Sean P. Nordt

    2015-12-01

    Full Text Available A 37-year-old male presented to the emergency department (ED in police custody for “medical clearance” before being taken to jail. The patient was approached by police officers for suspicion of selling illicit drugs. When approached by police he ran away and was witnessed to swallow several small plastic baggies suspected to contain heroin. He was apprehended and brought to the ED. On arrival, he was asymptomatic with a blood pressure 144/83mmHg, heart rate 67bpm, respiratory rate of 19bpm, oxygen saturation of 99% on room air and afebrile. A Glasgow coma score was 15 and he was alert and oriented to person, place and time. Patient had a negative review of systems. On physical examination pupils were 4mm and reactive to light, lungs clear to auscultation and had normal respiratory rate with normal cardiovascular exam. Abdomen was soft, non-tender and non-distended with present bowel sounds. The patient admitted to ingesting approximately 20 packets of heroin to avoid being charged with possession. The patient declined activated charcoal and whole bowel irrigation (WBI with polyethylene glycol-electrolyte solution (PEG-ELS. The patient declined a urine toxicology immunoassay screen. A computed tomography (CT of his abdomen with contrast was obtained and read as normal except for a cluster of foreign bodies within the distal stomach likely contained within a plastic bag.

  13. Computed tomography characterisation of additive manufacturing materials.

    Science.gov (United States)

    Bibb, Richard; Thompson, Darren; Winder, John

    2011-06-01

    Additive manufacturing, covering processes frequently referred to as rapid prototyping and rapid manufacturing, provides new opportunities in the manufacture of highly complex and custom-fitting medical devices and products. Whilst many medical applications of AM have been explored and physical properties of the resulting parts have been studied, the characterisation of AM materials in computed tomography has not been explored. The aim of this study was to determine the CT number of commonly used AM materials. There are many potential applications of the information resulting from this study in the design and manufacture of wearable medical devices, implants, prostheses and medical imaging test phantoms. A selection of 19 AM material samples were CT scanned and the resultant images analysed to ascertain the materials' CT number and appearance in the images. It was found that some AM materials have CT numbers very similar to human tissues, FDM, SLA and SLS produce samples that appear uniform on CT images and that 3D printed materials show a variation in internal structure.

  14. Computed tomography with selectable image resolution

    International Nuclear Information System (INIS)

    A computed tomography system x-ray detector has a central group of half-width detector elements and groups of full-width elements on each side of the central group. To obtain x-ray attenuation data for whole body layers, the half-width elements are switched effectively into paralleled pairs so all elements act like full-width elements and an image of normal resolution is obtained. For narrower head layers, the elements in the central group are used as half-width elements so resolution which is twice as great as normal is obtained. The central group is also used in the half-width mode and the outside groups are used in the full-width mode to obtain a high resolution image of a body zone within a full body layer. In one embodiment data signals from the detector are switched by electronic multiplexing and in another embodiment a processor chooses the signals for the various kinds of images that are to be reconstructed. (author)

  15. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Carina Mari Aparici

    2016-01-01

    Full Text Available We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG-positron emission tomography (PET/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  16. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography.

    Science.gov (United States)

    Aparici, Carina Mari; Win, Aung Zaw

    2016-01-01

    We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT) showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG)-positron emission tomography (PET)/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results. PMID:27625897

  17. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Vermelho, Marli Batista Fernandes; Correia, Ademir Silva; Michailowsky, Tania Cibele de Almeida; Suzart, Elizete Kazumi Kuniyoshi; Ibanes, Aline Santos; Almeida, Lanamar Aparecida; Khoury, Zarifa; Barba, Mario Flores, E-mail: marlivermelho@globo.com [Instituto de Infectologia Emilio Ribas (IIER), Sao Paulo, SP (Brazil)

    2015-03-15

    Objective: to evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and methods: retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results: abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion: computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. (author)

  18. Diffuse abnormalities of the trachea: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia]. E-mail: edmarchiori@gmail.com; Pozes, Aline Serfaty [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Faculdade de Medicina. Dept. de Radiologia; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Escola de Medicina. Dept. de Radiologia; Escuissato, Dante Luiz [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Dept. de Radiologia; Irion, Klaus Loureiro [The Cardiothoracic Centre NHS Trust, Liverpool (United Kingdom); Araujo Neto, Cesar de [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil). Dept. de Radiologia; Barillo, Jorge Luiz; Zanetti, Glaucia [Faculdade de Medicina de Petropolis (FMP), RJ (Brazil). Dept. de Cirurgia Clinica; Souza, Carolina Althoff [University of Ottawa, Ottawa, ON (Canada)

    2008-01-15

    The aim of this pictorial essay was to present the main computed tomography findings seen in diffuse diseases of the trachea. The diseases studied included amyloidosis, tracheobronchopathia osteochondroplastica, tracheobronchomegaly, laryngotracheobronchial papillomatosis, lymphoma, neurofibromatosis, relapsing polychondritis, Wegener's granulomatosis, tuberculosis, paracoccidioidomycosis, and tracheobronchomalacia. The most common computed tomography finding was thickening of the walls of the trachea, with or without nodules, parietal calcifications, or involvement of the posterior wall. Although computed tomography allows the detection and characterization of diseases of the central airways, and the correlation with clinical data reduces the diagnostic possibilities, bronchoscopy with biopsy remains the most useful procedure for the diagnosis of diffuse lesions of the trachea. (author)

  19. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings

    International Nuclear Information System (INIS)

    Objective: to evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and methods: retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results: abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion: computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. (author)

  20. Diagnosis of hoof disease in horses using computed tomography

    Directory of Open Access Journals (Sweden)

    Kovač Milomir

    2002-01-01

    Full Text Available This study describes findings of computed tomography investigations at the Bergische Equine Clinic (Germany of 39 horses with hoof diseaseas. The most frequently findings were the navicular syndrome (eight horses, laminitis (seven horses, keratnoma (six horses and ossification of collateral cartilages in the distal phalanx (four horses. The special value of the computed tomography is in evaluating the size and courses fracture/fissure of the navicular and koffin bones, which were diagnose in five horses. In four of horses no pathologic changes of the hoof were determined by computed tomography.

  1. Calcium score of small coronary calcifications on multidetector computed tomography

    DEFF Research Database (Denmark)

    Groen, J M; Kofoed, K F; Zacho, M;

    2013-01-01

    Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which ena...

  2. Positron emission tomography/computed tomography for optimized colon cancer staging and follow up

    DEFF Research Database (Denmark)

    Engelmann, Bodil Elisabeth; Loft, Annika; Kjær, Andreas;

    2014-01-01

    OBJECTIVES: Optimal management of colon cancer (CC) requires detailed assessment of extent of disease. This study prospectively investigates the diagnostic accuracy of 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/computed tomography (PET/CT) for staging and detection of recurrence...

  3. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle Westergren;

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present s...

  4. Fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography in evaluation of residual intramuscular myxoma

    International Nuclear Information System (INIS)

    Intramuscular myxoma (IM) is a rare benign neoplasm. In a patient diagnosed with IM of left thigh, we report the utility of a postoperative fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography scan in assessing the efficacy of surgical excision

  5. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W;

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  6. The Use of GPUs for Solving the Computed Tomography Problem

    Directory of Open Access Journals (Sweden)

    A.E. Kovtanyuk

    2014-07-01

    Full Text Available Computed tomography (CT is a widespread method used to study the internal structure of objects. The method has applications in medicine, industry and other fields of human activity. In particular, Electronic Imaging, as a species CT, can be used to restore the structure of nanosized objects. Accurate and rapid results are in high demand in modern science. However, there are computational limitations that bound the possible usefulness of CT. On the other hand, the introduction of high-performance calculations using Graphics Processing Units (GPUs provides improving quality and performance of computed tomography investigations. Moreover, parallel computing with GPUs gives significantly higher computation speeds when compared with (Central Processing Units CPUs, because of architectural advantages of the former. In this paper a computed tomography method of recovering the image using parallel computations powered by NVIDIA CUDA technology is considered. The implementation of this approach significantly reduces the required time for solving the CT problem.

  7. Computed Tomography diagnosis of skeletal involvement in multiple myeloma

    International Nuclear Information System (INIS)

    The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary permeative lesion in the left public bone, which facilitated subsequent biopsy. As for extraosseous localizations, Computed Tomography demonstrated thoracic soft tissue (1 woman) and pelvic (1 man) involvement by myelomtous masses penetrating into surrounding tissues. In our series, only a case of osteosclerotic bone myeloma was observed in the pelvis, associated with lytic abnormalities. Computed Tomography findings do not seem to improve the clinical approach and therapeutic management of the disease. Nevertheless, the authors reccommend Computed Tomography for some myelomatous conditions, namely: a) in the patients with focal bone pain but normal skeletal radiographs; b) in the patients with M protein, bone marrow plasmocytosis and back pain, but with an incoclusive multiple myeloma diagnosis; c) to asses bone spread in the regions which are anatomically complex or difficult to study with radiography and to depict soft tissue involvement; d) for bone biopsy

  8. Dose modulated computed tomography automated dosimetry

    International Nuclear Information System (INIS)

    Full text: Computed Tomography (CT) scans contribute a significant portion of the effective radiation dose from medical procedures and generally large effective radiation doses per diagnostic examination. With the advent of Multislice CT, the potential for large radiation exposures increased. This combined with the appeal of the resultant isotropic imaging and the increasing number of applications for which CT could be utilised (including screening procedures) has further increased the need for vigilant monitoring of CT protocols and use with respect to radiation dose. The introduction of dose modulated Computed Tomography has proven an effective method for reducing patient dose and is now widely used by CT manufacturers. This involves lowering the mA when scanning through anatomical regions which do not require a large mA. Many CT investigations now utilise dose modulation. Some of these studies will include over 900 images for which the mA and occasionally other factors could vary. In order to utilise the existing software to perform CT dosimetry a program has been written to automatically extract scan parameters from CT dicom image files and apply the ImPACT CT Patient Dosimetry Calculator, for slices with differing factors. Matlab has been used to write and compile a program which sorts through a folder of dicom images and extracts the appropriate dicom header information. Some manufacturers store different series and reformatted images all within the same folder. The images of the CT study for which the dosimetry is to be performed must be stored within the one folder and must be in a dicom format. The program has been written to accommodate several manufacturers, which all contain different information in their dicom headers. The Matlab program groups the various study/image types, extracting the relevant dicom header information, which is written to an Excel worksheet. An Excel file uses this information to run the ImPACT CT Patient Dosimetry Calculator with

  9. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase 2 project, we propose to develop, construct, and deliver to NASA a computed axial tomography time-domain terahertz (CT TD-THz) non destructive...

  10. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to demonstrate key elements of feasibility for a high speed automated time domain terahertz computed axial tomography (TD-THz CT) non destructive...

  11. Computed tomography of diffuse pulmonary diseases

    International Nuclear Information System (INIS)

    This article summarizes our preliminary results on high resolution computed tomography of 101 patients with various diffuse lung diseases. Instead of pattern recognition routinely done on chest radiogram (nodular, reticular or reticulo-nodular) we emphasized the relation of the lesions with inherent structures of the lung seen on the CT images. For this purpose our ten years radiologic-pathologic correlation on inflated and fixed lung specimens proved quite useful. 1) Centrilobular inflammatory nodules. This was seen in diffuse panbronchiolitis (DPB), allergic broncho-pulmonary aspergillosis, tuberculosis, pneumoconiosis and lobular pneumonia. DPB and bronchogenic spread of tuberculosis were most representative. The nodules produced by these diseases were located at the extreme end of bronchial branchings and separated by 2 to 3 mm from the pleura and pulmonary vein which constitute the edge of the secondary pulmonary lobule. 2) The lesions extending along bronchoarterial sheath and pulmonary vein. The contours of the pulmonary vessels were irregular and their calibers enlarged. These findings were seen in sarcoidosis and lymphangiosis carcinomatosa. 3) Lobular and multilobular lesions. This was seen in diffuse interstitial pneumonia and in alveolar filling diseases. The margins of the lesions were straight or curved slightly suggesting that disease is blocked by the lobular septa. Fine air bronchogram within the lesions was characteristic in chronic interstitial pneumonia. 4) Slight to moderate increase of lung density with multilobular distribution. This was seen in interstitial pneumonia, sarcoidosis and hypersensitivity pneumonitis. We supposed that this finding corresponds to cellular or fibrous thickening of alveolar septa, but direct proof was not available. (J.P.N.)

  12. Computed tomography in Duchenne type muscular dystrophy

    International Nuclear Information System (INIS)

    The computed tomography (CT) scan was performed on 91 Duchenne type muscular dystrophy (DMD) patients on the following four levels; (1) at the level of L3 vertebra, (2) 2-3cm above the symphysis pubica, (3) midposition of the thigh, (4) largest-diameter section of the lower leg. The CT of muscles common to most of the DMD patients were as follows: 1. Muscle atrophy: Muscle atrophy was shown as a reduction in the cross-sectional area of the muscles. Very mild muscle atrophy could be detected either by the clearly identified muscle border or by scattered low-density areas of so-called ''moth-eaten'' appearance within muscles. 2. Fat infiltration: The decrease in radio-density of muscles was interpreted as infiltration of fatty tissue. This type of density change was further classified into diffuse, streaked, cobblestone and salt-and-pepper patterns according to the spacial distribution of low-density areas. 3. Selectivity pattern: As the chronological sequence of DMD muscle degeneration is usually different among individual muscles, it may be seen, in some stages, that some of the synergistic muscles are still only slightly involved, while the others are quite severely atrophied with evident fat infiltration. In certain stages of the disease, most of the patients show relative preservation of particular muscles although they assumed a rounded shape. The most resistent muscle was musculus gracilis, followed by the musculus sartorius, musculus semitendinosus (and/or musculus semimembranosus) in that order. According to the severity of the CT changes, 86 of the 91 patients were classed into five stages from A1 to A5. Morphological stages (A1-A5) were well correlated to the functional disability stages by Ueda with a correlation factor of r=0.88. (J.P.N.)

  13. Characterization of HPGe detectors using Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hedman, A., E-mail: Angelica.Hedman@foi.se [Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå (Sweden); Umeå University, Department of Radiation Sciences, Radiation Physics, SE-90187 Umeå (Sweden); Bahar Gogani, J.; Granström, M. [Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå (Sweden); Johansson, L.; Andersson, J.S. [Umeå University, Department of Radiation Sciences, Radiation Physics, SE-90187 Umeå (Sweden); Ramebäck, H. [Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå (Sweden); Chalmers University of Technology, Department of Chemical and Biological Engineering, Nuclear Chemistry, SE-41296 Göteborg (Sweden)

    2015-06-11

    Computed Tomography (CT) high-resolution imaging have been used to investigate if there is a significant change in the crystal-to-window distance, i.e. the air gap thickness, in a small n-type detector cooled to 77 K, and in a medium sized p-type HPGe detector when cooled to 100 K. The findings were compared to detector dimension data made available by the manufacturer. The air gap thickness increased by (0.38±0.07) mm for the n-type detector and by (0.40±0.15) mm for the p-type detector when the detectors were cooled to 77 resp. 100 K compared to at room temperature. Monte Carlo calculations indicate that these differences have a significant impact on the efficiency in close geometries (<5 cm). In the energy range of 40–700 keV with a source placed directly on endcap, the change in detector efficiency with temperature is 1.9–2.9% for the n-type detector and 0.3–2.1% for the p-type detector. The measured air gap thickness when cooling the detector was 1.1 mm thicker than manufacturer data for the n-type detector and 0.2 mm thicker for the p-type detector. In the energy range of 40–700 keV and with a source on endcap, this result in a change in detector efficiency of 5.2–7.1% for the n-type detector and 0.2–1.0% for the p-type detector, i.e. the detector efficiency is overestimated using data available by the manufacturer.

  14. Dose in x-ray computed tomography.

    Science.gov (United States)

    Kalender, Willi A

    2014-02-01

    Radiation dose in x-ray computed tomography (CT) has become a topic of high interest due to the increasing numbers of CT examinations performed worldwide. This review aims to present an overview of current concepts for both scanner output metrics and for patient dosimetry and will comment on their strengths and weaknesses. Controversial issues such as the appropriateness of the CT dose index (CTDI) are discussed in detail. A review of approaches to patient dose assessment presently in practice, of the dose levels encountered and options for further dose optimization are also given and discussed. Patient dose assessment remains a topic for further improvement and for international consensus. All approaches presently in use are based on Monte Carlo (MC) simulations. Estimates for effective dose are established, but they are crude and not patient-specific; organ dose estimates are rarely available. Patient- and organ-specific dose estimates can be provided with adequate accuracy and independent of CTDI phantom measurements by fast MC simulations. Such information, in particular on 3D dose distributions, is important and helpful in optimization efforts. Dose optimization has been performed very successfully in recent years and even resulted in applications with effective dose values of below 1 mSv. In general, a trend towards lower dose values based on technical innovations has to be acknowledged. Effective dose values are down to clearly below 10 mSv on average, and there are a number of applications such as cardiac and pediatric CT which are performed routinely below 1 mSv on modern equipment. PMID:24434792

  15. Myocardial perfusion with multi-detector computed tomography: quantitative evaluation

    International Nuclear Information System (INIS)

    The objective of this work is to evaluate the skill of multidetector computer tomography, to quantify the different patterns of intensification during the evaluation of the myocardial perfusion. 45 patients were studied with suspicion of cardiovascular disease. Multi-detector computed tomography was utilized on patients at rest and in effort with pharmacological stress, after the administration of dipyridamole. Also they were evaluated using nuclear medicine

  16. Skeletal dosimetry in cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Walters, B. R. B.; Ding, G. X.; Kramer, R.; Kawrakow, I. [Ionizing Radiation Standards, National Research Council of Canada, Ottawa K1A OR6 (Canada); Department of Radiation Oncology, Vanderbilt-Ingram Cancer Center, Vanderbilt University School of Medicine, Nashville, Tennessee 37232-5671 (United States); Departamento de Energia Nuclear, Universidade Federal de Pernambuco, Avenida Professor Luiz Freire 1000, Cidade Universitaria, CEP 50740-540, Recife, Pernambuco (Brazil); Ionizing Radiation Standards, National Research Council of Canada, Ottawa K1A OR6 (Canada)

    2009-07-15

    Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image-guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. In this study, voxelized human phantoms, FAX06 (adult female) and MAX06 (adult male), are used together with phase-space data collected from a realistic model of a CBCT imager to calculate dose in the red bone marrow (RBM) and bone surface cells (BSCs), the two organs at risk within the bone spongiosa, during simulated head and neck, chest and pelvis CBCT scans. The FAX06/MAX06 phantoms model spongiosa based on micro-CT images, filling the relevant phantom voxels, which are 0.12x0.12x0.12 cm{sup 3}, with 17x17x17 {mu}m{sup 3} microvoxels to form a micromatrix of trabecular bone and bone marrow. FAX06/MAX06 have already been implemented in an EGSnrc-based Monte Carlo code to simulate radiation transport in the phantoms; however, this study required significant modifications of the code to allow use of phase-space data from a simulated CBCT imager as a source and to allow scoring of total dose, RBM dose and BSC dose on a voxel-by-voxel basis. In simulated CBCT scans, the BSC dose is significantly greater than the dose to other organs at risk. For example, in a simulated head and neck scan, the average BSC dose is 25% higher than the average dose to eye lens ({approx}8.3 cGy), and 80% greater than the average dose to brain (5.7 cGy). Average dose to RBM, on the other hand, is typically only {approx}50% of the average BSC dose and less than the dose to other organs at risk (54% of the dose to eye lens and 76% of dose to brain in a head and neck scan). Thus, elevated dose in bone due to CBCT results in elevated BSC dose. This is potentially of concern when using CBCT in conjunction with radiotherapy treatment.

  17. Skeletal dosimetry in cone beam computed tomography.

    Science.gov (United States)

    Walters, B R B; Ding, G X; Kramer, R; Kawrakow, I

    2009-07-01

    Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image-guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. In this study, voxelized human phantoms, FAX06 (adult female) and MAX06 (adult male), are used together with phase-space data collected from a realistic model of a CBCT imager to calculate dose in the red bone marrow (RBM) and bone surface cells (BSCs), the two organs at risk within the bone spongiosa, during simulated head and neck, chest and pelvis CBCT scans. The FAX06/MAX06 phantoms model spongiosa based on micro-CT images, filling the relevant phantom voxels, which are 0.12 x 0.12 x 0.12 cm3, with 17 x 17 x 17 microm3 microvoxels to form a micromatrix of trabecular bone and bone marrow. FAX06/ MAX06 have already been implemented in an EGSnrc-based Monte Carlo code to simulate radiation transport in the phantoms; however, this study required significant modifications of the code to allow use of phase-space data from a simulated CBCT imager as a source and to allow scoring of total dose, RBM dose and BSC dose on a voxel-by-voxel basis. In simulated CBCT scans, the BSC dose is significantly greater than the dose to other organs at risk. For example, in a simulated head and neck scan, the average BSC dose is 25% higher than the average dose to eye lens (approximately 8.3 cGy), and 80% greater than the average dose to brain (5.7 cGy). Average dose to RBM, on the other hand, is typically only approximately 50% of the average BSC dose and less than the dose to other organs at risk (54% of the dose to eye lens and 76% of dose to brain in a head and neck scan). Thus, elevated dose in bone due to CBCT results in elevated BSC dose. This is potentially of concern when using CBCT in conjunction with radiotherapy treatment. PMID:19673190

  18. Skeletal dosimetry in cone beam computed tomography

    International Nuclear Information System (INIS)

    Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image-guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. In this study, voxelized human phantoms, FAX06 (adult female) and MAX06 (adult male), are used together with phase-space data collected from a realistic model of a CBCT imager to calculate dose in the red bone marrow (RBM) and bone surface cells (BSCs), the two organs at risk within the bone spongiosa, during simulated head and neck, chest and pelvis CBCT scans. The FAX06/MAX06 phantoms model spongiosa based on micro-CT images, filling the relevant phantom voxels, which are 0.12x0.12x0.12 cm3, with 17x17x17 μm3 microvoxels to form a micromatrix of trabecular bone and bone marrow. FAX06/MAX06 have already been implemented in an EGSnrc-based Monte Carlo code to simulate radiation transport in the phantoms; however, this study required significant modifications of the code to allow use of phase-space data from a simulated CBCT imager as a source and to allow scoring of total dose, RBM dose and BSC dose on a voxel-by-voxel basis. In simulated CBCT scans, the BSC dose is significantly greater than the dose to other organs at risk. For example, in a simulated head and neck scan, the average BSC dose is 25% higher than the average dose to eye lens (∼8.3 cGy), and 80% greater than the average dose to brain (5.7 cGy). Average dose to RBM, on the other hand, is typically only ∼50% of the average BSC dose and less than the dose to other organs at risk (54% of the dose to eye lens and 76% of dose to brain in a head and neck scan). Thus, elevated dose in bone due to CBCT results in elevated BSC dose. This is potentially of concern when using CBCT in conjunction with radiotherapy treatment.

  19. Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Faccioli, Niccolo; Foti, Giovanni; Barillari, Marco; Mucelli, Roberto Pozzi [University of Verona, Department of Radiology, G.B. Rossi Hospital, Verona (Italy); Atzei, Andrea [University of Verona, Department of Hand Surgery, G.B. Rossi Hospital, Verona (Italy)

    2010-11-15

    To compare the diagnostic accuracy and radiation exposure of cone beam computed tomography (CBCT) and multislice computed tomography (MSCT) in the evaluation of finger fractures. In a 3-year period, 57 consecutive patients with post-traumatic fractures of the metacarpal-phalangeal (MCP), proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints with involvement of the articular surface were studied by means of CBCT and MSCT. Student's t test was used to compare CBCT and MSCT accuracy in evaluating the percentage of joint surface involvement and in detecting bone fragments. The average tissue-absorbed doses of CBCT and MSCT were also compared. A value of p < 0.05 was considered statistically significant. Inter-observer agreement was calculated. In all cases, CBCT allowed the percentage of articular involvement to be correctly depicted compared with MSCT, showing 100% sensitivity and specificity (p < 0.001). A total of 103 bone fragments were depicted on MSCT (mean 3.8 per patient, range 1-23). CBCT indicated 92 out of 103 fragments (89.3%) compared with MSCT (mean diameter of missed fragments 0.9 mm, range 0.6-1.3 mm), with no statistically significant difference between CBCT and MSCT (p < 0.025). Multislice CT radiation exposure was significantly higher than that of CBCT (0.18 mSv vs 0.06 mSv, p < 0.0025). Inter-observer agreement was good (overall {kappa} = 0.89-0.96). Cone beam CT may be considered a valuable imaging tool in the preoperative assessment of finger fractures, when MSCT is not available. (orig.)

  20. Endocrine radionuclide scintigraphy with fusion single photon emission computed tomography/computed tomography

    Science.gov (United States)

    Wong, Ka-Kit; Gandhi, Arpit; Viglianti, Benjamin L; Fig, Lorraine M; Rubello, Domenico; Gross, Milton D

    2016-01-01

    AIM: To review the benefits of single photon emission computed tomography (SPECT)/computed tomography (CT) hybrid imaging for diagnosis of various endocrine disorders. METHODS: We performed MEDLINE and PubMed searches using the terms: “SPECT/CT”; “functional anatomic mapping”; “transmission emission tomography”; “parathyroid adenoma”; “thyroid cancer”; “neuroendocrine tumor”; “adrenal”; “pheochromocytoma”; “paraganglioma”; in order to identify relevant articles published in English during the years 2003 to 2015. Reference lists from the articles were reviewed to identify additional pertinent articles. Retrieved manuscripts (case reports, reviews, meta-analyses and abstracts) concerning the application of SPECT/CT to endocrine imaging were analyzed to provide a descriptive synthesis of the utility of this technology. RESULTS: The emergence of hybrid SPECT/CT camera technology now allows simultaneous acquisition of combined multi-modality imaging, with seamless fusion of three-dimensional volume datasets. The usefulness of combining functional information to depict the bio-distribution of radiotracers that map cellular processes of the endocrine system and tumors of endocrine origin, with anatomy derived from CT, has improved the diagnostic capability of scintigraphy for a range of disorders of endocrine gland function. The literature describes benefits of SPECT/CT for 99mTc-sestamibi parathyroid scintigraphy and 99mTc-pertechnetate thyroid scintigraphy, 123I- or 131I-radioiodine for staging of differentiated thyroid carcinoma, 111In- and 99mTc- labeled somatostatin receptor analogues for detection of neuroendocrine tumors, 131I-norcholesterol (NP-59) scans for assessment of adrenal cortical hyperfunction, and 123I- or 131I-metaiodobenzylguanidine imaging for evaluation of pheochromocytoma and paraganglioma. CONCLUSION: SPECT/CT exploits the synergism between the functional information from radiopharmaceutical imaging and anatomy

  1. Computed tomography in penetrating injury to the eye.

    Science.gov (United States)

    Bhimani, S; Virapongse, C; Sarwar, M; Twist, J F

    1984-05-01

    We used computed tomography to detect and localize foreign bodies in two unusual cases of penetrating injury to the eyes. In one case, a large broken twig appeared to have penetrated the globe and the inferior rectus muscle; in the other, the globe was ruptured by many glass shards . In the first case surgery showed the computed tomographic impression to be incorrect. The globe and the inferior rectus muscle were intact and vision and motility were normal postoperatively. In the second case, swelling made direct visualization impossible, and computed tomography was used to locate the foreign bodies. PMID:6720836

  2. Development of a proton Computed Tomography Detector System

    CERN Document Server

    Naimuddin, Md; Blazey, G; Boi, S; Dyshkant, A; Erdelyi, B; Hedin, D; Johnson, E; Krider, J; Rukalin, V; Uzunyan, S A; Zutshi, V; Fordt, R; Sellberg, G; Rauch, J E; Roman, M; Rubinov, P; Wilson, P

    2015-01-01

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantageous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

  3. Development of a proton Computed Tomography detector system

    International Nuclear Information System (INIS)

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantegeous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector

  4. Coronary computed tomography angiography indicates complexity of percutaneous coronary interventions

    OpenAIRE

    Stähli, B E; Bonassin, F; Goetti, R; Küest, S M; Frank, M.; Altwegg, L A; Gebhard, C; Levis, A; Wischnewsky, M. B.; Lüscher, T F; Alkadhi, H.; Kaufmann, P A; Maier, W.

    2012-01-01

    BACKGROUND: Coronary computed tomography angiography (CCTA) provides information regarding lesion morphology and three-dimensional coronary anatomy incremental to coronary angiography. We addressed the question whether preprocedural CCTA bears potential for guiding percutaneous coronary interventions (PCI). METHODS AND RESULTS: Sixty-six coronary lesions attempted with PCI within 6 months of preprocedural CCTA were retrospectively assessed. Lesion parameters from unenhanced computed tomogr...

  5. 3D neutron computed tomography. Requirements and applications

    International Nuclear Information System (INIS)

    Other than X-rays, neutrons can penetrate most metals easily while delivering a high contrast for many light-weight elements. Especially their high sensitivity for hydrogen makes them a valuable tool for the detection of organic materials like lubricants, plastics or sealants within metal housings. Neutron radiography and tomography complement the application of X-ray for the inspection of complex and critical components like in automotive and aerospace applications. An overview about the technical and mathematical differences between neutron and X-ray tomography is given and the imperfections and limitations of a neutron setup are shown. Several examples of technical neutron computed tomography are given. (author)

  6. Dose estimation for paediatric cranial computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Curci Daros, K.A.; Bitelli Medeiros, R. [Sao Paulo Univ. Federal (Brazil); Curci Daros, K.A.; Oliveira Echeimberg, J. de [Centro Univ. Sao Camilo, Sao Paulo (Brazil)

    2006-07-01

    In the last ten years, the number of paediatric computed tomography (CT) scans have increased worldwide, contributing to higher population radiation dose. Technique diversification in paediatrics and different CT equipment technologies have led to various exposure levels complicating precise evaluation of doses and operational conditions necessary for good quality images. The objective of this study was to establish a quantitative relationship between absorbed dose and cranial region in children up to 6 years old undergoing CT exams. Methods: X-ray was measured on the cranial surface of 64 patients undergoing CT using thermoluminescent (T.L.) dosimeters. Forty T.L.D.100 thermoluminescent dosimeters (T.L.D.) were evenly distributed on each patients skin surface along the sagittal axis. Measurements were performed in facial regions exposed to scatter radiation and in the supratentorial and posterior fossa regions, submitted to primary radiation. T.L.D. were calibrated for 120 kV X-ray over the acrylic phantom. T.L. measurements were made with a Harshaw 4000 system. Patient mean T.L. readings were determined for position, pi, of T.L.D. and normalized to the maximum supratentorial reading. From integrating the linear T.L. density function (?) resulting from radiation distribution in each of the three exposed regions, dose fraction was determined in the region of interest, along with total dose under the technical conditions used in that specific exam protocol. For each T.L.D. position along the patient cranium, there were n T.L. measurements with 2% uncertainty due to T.L. reader, and 5% due to thermal treatment of dosimeters. Also, mean T.L. readings and their uncertainties were calculated for each patient at each position, p. Results: Mean linear T.L. density for the region exposed to secondary radiation defined by position, 0.3{<=}p{<=}6 cm, was {rho}((p)=7.9(4)x10{sup -2}+7(5)x10{sup -5}p{sup 4.5(4)} cm{sup -1}; exposed to primary X-ray for the posterior fossa

  7. Evaluating iterative reconstruction performance in computed tomography

    International Nuclear Information System (INIS)

    Purpose: Iterative reconstruction (IR) offers notable advantages in computed tomography (CT). However, its performance characterization is complicated by its potentially nonlinear behavior, impacting performance in terms of specific tasks. This study aimed to evaluate the performance of IR with both task-specific and task-generic strategies. Methods: The performance of IR in CT was mathematically assessed with an observer model that predicted the detection accuracy in terms of the detectability index (d′). d′ was calculated based on the properties of the image noise and resolution, the observer, and the detection task. The characterizations of image noise and resolution were extended to accommodate the nonlinearity of IR. A library of tasks was mathematically modeled at a range of sizes (radius 1–4 mm), contrast levels (10–100 HU), and edge profiles (sharp and soft). Unique d′ values were calculated for each task with respect to five radiation exposure levels (volume CT dose index, CTDIvol: 3.4–64.8 mGy) and four reconstruction algorithms (filtered backprojection reconstruction, FBP; iterative reconstruction in imaging space, IRIS; and sinogram affirmed iterative reconstruction with strengths of 3 and 5, SAFIRE3 and SAFIRE5; all provided by Siemens Healthcare, Forchheim, Germany). The d′ values were translated into the areas under the receiver operating characteristic curve (AUC) to represent human observer performance. For each task and reconstruction algorithm, a threshold dose was derived as the minimum dose required to achieve a threshold AUC of 0.9. A task-specific dose reduction potential of IR was calculated as the difference between the threshold doses for IR and FBP. A task-generic comparison was further made between IR and FBP in terms of the percent of all tasks yielding an AUC higher than the threshold. Results: IR required less dose than FBP to achieve the threshold AUC. In general, SAFIRE5 showed the most significant dose reduction

  8. Evaluating iterative reconstruction performance in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Baiyu, E-mail: chenby04@gmail.com; Solomon, Justin [Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 and Carl E. Ravin Advanced Imaging Laboratories, Duke University, Durham, North Carolina 27705 (United States); Ramirez Giraldo, Juan Carlos [Siemens Healthcare, Malvern, Pennsylvania 19355 (United States); Samei, Ehsan [Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Duke University, Durham, North Carolina 27705 (United States); Departments of Radiology, Physics, Biomedical Engineering, and Electronic and Computer Engineering, Duke University, Durham, North Carolina 27705 (United States)

    2014-12-15

    Purpose: Iterative reconstruction (IR) offers notable advantages in computed tomography (CT). However, its performance characterization is complicated by its potentially nonlinear behavior, impacting performance in terms of specific tasks. This study aimed to evaluate the performance of IR with both task-specific and task-generic strategies. Methods: The performance of IR in CT was mathematically assessed with an observer model that predicted the detection accuracy in terms of the detectability index (d′). d′ was calculated based on the properties of the image noise and resolution, the observer, and the detection task. The characterizations of image noise and resolution were extended to accommodate the nonlinearity of IR. A library of tasks was mathematically modeled at a range of sizes (radius 1–4 mm), contrast levels (10–100 HU), and edge profiles (sharp and soft). Unique d′ values were calculated for each task with respect to five radiation exposure levels (volume CT dose index, CTDI{sub vol}: 3.4–64.8 mGy) and four reconstruction algorithms (filtered backprojection reconstruction, FBP; iterative reconstruction in imaging space, IRIS; and sinogram affirmed iterative reconstruction with strengths of 3 and 5, SAFIRE3 and SAFIRE5; all provided by Siemens Healthcare, Forchheim, Germany). The d′ values were translated into the areas under the receiver operating characteristic curve (AUC) to represent human observer performance. For each task and reconstruction algorithm, a threshold dose was derived as the minimum dose required to achieve a threshold AUC of 0.9. A task-specific dose reduction potential of IR was calculated as the difference between the threshold doses for IR and FBP. A task-generic comparison was further made between IR and FBP in terms of the percent of all tasks yielding an AUC higher than the threshold. Results: IR required less dose than FBP to achieve the threshold AUC. In general, SAFIRE5 showed the most significant dose reduction

  9. Multifocal sparganosis mimicking lymphoma involvement: Multimodal imaging findings of ultrasonography, CT, MRI, and position emission tomography-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heo, So Young; Park, Ji Yeon; Park, Noh Hyuck; Park, Chan Sub; Kim, Tae Jung [Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of); Yi, Seong Yoon [Dev. of Hematology-Omcology, Dept. of Internal Medicine, Inje University Ilsan Paik Hospital, Goyang (Korea, Republic of); Jun, Hyun Jung [Dev. of Hematology-Omcology, Dept. of Internal Medicine, Seoul Medical Center, Seoul (Korea, Republic of)

    2016-01-15

    Sparganosis is a rare parasitic disease caused by the migrating plerocercoid larva of Spirometra species tapeworms. The most frequent clinical manifestation is a subcutaneous nodule resembling a neoplasm. In this study, we presented multimodal findings of ultrasonography, computed tomography, magnetic resonance imaging, positron emission tomography-computed tomography and follow-up imagings on multifocal sparganosis, mimicking lymphoma involvement in a patient with lymphoma.

  10. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W;

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...... study investigates the positive (PPV) and negative predictive value (NPV) of PET-CT in stage I disease and the clinical impact of the scan results in all disease stages....

  11. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Clarissa Aguiar de [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Instituto do Coracao (InCor)]. E-mail: clarissaaguiarm@yahoo.com.br; Baena, Marcos Eduardo da Silva [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Ultrasonography; Uezumi, Kiyomi Kato [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Computed Tomography; Castro, Claudio Campi de [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Magnetic Resonance Imaging; Lucarelli, Claudio Luiz [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Center of Diagnosis; Cerri, Giovanni Guido [Universidade de Sao Paulo (USP), SP (Brazil). School of Medicine. Dept. of Radiology

    2008-07-15

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  12. The current concepts of computed tomography for acute stroke

    International Nuclear Information System (INIS)

    Stroke is one of a leading cause of death and disability worldwide. The major advances in stroke therapy in particular invasive therapy lead to application of new imaging techniques. The aim of this review is to present state-of-the-art concepts of computed tomography for acute stroke. The goals of a neuroimaging in acute stroke are to establish a diagnosis as early as possible and to evaluate brain perfusion and intracranial vessels' patency. State-of-the-art imaging in the era of multidetector computed tomography (CT) with high spatial and temporal resolution consists of multimodal CT imaging. Non enhanced CT is necessary for depiction of hemorrhage or early ischemic signs. CT angiography evaluates intravascular thrombi or significant stenosis, and CT perfusion demonstrates salvageable tissue at risk. By combining different imaging techniques in multimodal approach we can acquire information necessary for therapeutic planning and could select patients for thrombolysis. The imaging protocol should be tailored to the patient regarding to the time of onset, necessity and availability of CT modalities. (authors) Key words: Stroke. Computed Tomography (CT). Computed Tomography Angiography (CTA). Computed Tomography Perfusion (CTP)

  13. Shielding Calculations for Positron Emission Tomography - Computed Tomography Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Baasandorj, Khashbayar [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Yang, Jeongseon [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-10-15

    Integrated PET-CT has been shown to be more accurate for lesion localization and characterization than PET or CT alone, and the results obtained from PET and CT separately and interpreted side by side or following software based fusion of the PET and CT datasets. At the same time, PET-CT scans can result in high patient and staff doses; therefore, careful site planning and shielding of this imaging modality have become challenging issues in the field. In Mongolia, the introduction of PET-CT facilities is currently being considered in many hospitals. Thus, additional regulatory legislation for nuclear and radiation applications is necessary, for example, in regulating licensee processes and ensuring radiation safety during the operations. This paper aims to determine appropriate PET-CT shielding designs using numerical formulas and computer code. Since presently there are no PET-CT facilities in Mongolia, contact was made with radiological staff at the Nuclear Medicine Center of the National Cancer Center of Mongolia (NCCM) to get information about facilities where the introduction of PET-CT is being considered. Well-designed facilities do not require additional shielding, which should help cut down overall costs related to PET-CT installation. According to the results of this study, building barrier thicknesses of the NCCM building is not sufficient to keep radiation dose within the limits.

  14. Chase Lake Wetland Management District, Chase Lake National Wildlife Refuge, Chase Lake Prairie Project: Annual narrative report: 1997

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This annual narrative report for Chase Lake WMD, Chase Lake NWR, Chase Lake Prairie Project, and Halfway Lake NWR outlines Refuge accomplishments during the 1997...

  15. Evaluation of myocardial ischemia by multiple detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Fabio Vieira, E-mail: rccury@me.com [Hospital do Coracao (HCor), Sao Paulo, SP (Brazil); Cury, Roberto Caldeira [Hospital Samaritano, Sao Paulo, SP (Brazil)

    2015-01-15

    For years, cardiovascular diseases have been the leading cause of death worldwide, bringing on important social and economic consequences. Given this scenario, the search for a method capable of diagnosing coronary artery diseases in an early and accurate way is increasingly higher. The coronary computed tomography angiogram is already widely established for the stratification of coronary artery diseases, and, more recently, the computed tomography myocardial perfusion imaging has been providing relevant information by correlating ischemia and the coronary anatomy. The objective of this review is to describe the evaluation of myocardial ischemia by multiple detector computed tomography. This study will resort to controlled clinical trials that show the possibility of a single method to identify the atherosclerotic load, presence of coronary artery luminal narrowing and possible myocardial ischemia, by means of a fast, practical and reliable method validated by a multicenter study. (author)

  16. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Kwang Joon; Kim, Kyung A [School of Dentistry, Chonbuk National University, Jeonju (Korea, Republic of)

    2011-09-15

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  17. Computed tomography of the thorax in children with cystic fibrosis

    International Nuclear Information System (INIS)

    We studied retrospectively the value of computed tomography of the thorax in patients suffering from cystic fibrosis. Twenty-six patients were studied, which showed as the most frequency pulmonary findings bronchial wall thickening in 22 patients (84.6), followed by bronchiectasis in 16 patients (61.5%). Less frequent finding were ill-defined patch consolidation, mucoid impaction, bullaes and atelectasis. We found a predominant distribution of bronchial wall thickening and bronchiectasis in the upper lobes of the lungs. Computed tomography is the more sensitive technique for early visualization and location of the manifestations of cystic fibrosis bronchopathy. (author)

  18. A controlled study of positron-emission-tomography and positron-emission-tomography/computed tomography in differential diagnosis of solitary pulmonary nodules-report of 60 cases

    Institute of Scientific and Technical Information of China (English)

    DING Qi-yong; HUA Yan-qing; ZHANG Guo-zhen; ZHAO Jun; GUAN Yi-hui; GE Xiao-jun; MAO Ding-biao; ZUO Chuan-tao

    2005-01-01

    @@ The differential diagnosis of solitary pulmonary nodules (SPNs) remains a challenge. It is acknowledged that combining positron-emission tomography (PET) and computed tomography (CT) offers the most reliable noninvasive method for the diagnosis of SPNs.

  19. Missing wedge computed tomography by iterative algorithm DIRECTT.

    Science.gov (United States)

    Kupsch, Andreas; Lange, Axel; Hentschel, Manfred P; Lück, Sebastian; Schmidt, Volker; Grothausmann, Roman; Hilger, André; Manke, Ingo

    2015-01-01

    A strategy to mitigate typical reconstruction artefacts in missing wedge computed tomography is presented. These artefacts appear as elongations of reconstructed details along the mean direction (i.e. the symmetry centre of the projections). Although absent in standard computed tomography applications, they are most prominent in advanced electron tomography and also in special topics of X-ray and neutron tomography under restricted geometric boundary conditions. We investigate the performance of the DIRECTT (Direct Iterative Reconstruction of Computed Tomography Trajectories) algorithm to reduce the directional artefacts in standard procedures. In order to be sensitive to the anisotropic nature of missing wedge artefacts, we investigate isotropic substructures of metal foam as well as circular disc models. Comparison is drawn to filtered backprojection and algebraic techniques. Reference is made to reconstructions of complete data sets. For the purpose of assessing the reconstruction quality, Fourier transforms are employed to visualize the missing wedge directly. Deficient reconstructions of disc models are evaluated by a length-weighted kernel density estimation, which yields the probabilities of boundary orientations. The DIRECTT results are assessed at different signal-to-noise ratios by means of local and integral evaluation parameters. PMID:26367127

  20. Diagnostic utility of fluorodeoxyglucose positron emission tomography/computed tomography in pyrexia of unknown origin

    International Nuclear Information System (INIS)

    The present study was undertaken to evaluate the diagnostic utility of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) in patients presenting as pyrexia of unknown origin (PUO). Forty-seven patients (31 males and 16 females; mean age of 42.7 ± 19.96 years) presenting as PUO to the Department of Medicine at the All India Institute of Medical Sciences, New Delhi over a period of 2 years underwent F-18 FDG PET/CT. PET ⁄ CT was considered supportive when its results correlated with the final definitive diagnosis. Final diagnosis was made on the basis of combined evaluation of history, clinical findings, investigations, and response to treatment. Thirty-five PET/CT studies (74.5%) were positive. However, only 18 (38.3%) were supportive of the final diagnosis. In three patients (6.4%), PET/CT was considered diagnostic as none of the other investigations including contrast-enhanced computed tomography of chest and abdomen, and directed tissue sampling could lead to the final diagnosis. All these three patients were diagnosed as aortoarteritis. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography is an important emerging modality in the workup of PUO. It supported the final diagnosis in 38% of our patients and was diagnostic in 6.4% of patients. Thus, PET/CT should only be considered as second-line investigation for the diagnostic evaluation of PUO; especially in suspected noninfectious inflammatory disorders

  1. Industrial Computed Tomography using Proximal Algorithm

    KAUST Repository

    Zang, Guangming

    2016-04-14

    In this thesis, we present ProxiSART, a flexible proximal framework for robust 3D cone beam tomographic reconstruction based on the Simultaneous Algebraic Reconstruction Technique (SART). We derive the proximal operator for the SART algorithm and use it for minimizing the data term in a proximal algorithm. We show the flexibility of the framework by plugging in different powerful regularizers, and show its robustness in achieving better reconstruction results in the presence of noise and using fewer projections. We compare our framework to state-of-the-art methods and existing popular software tomography reconstruction packages, on both synthetic and real datasets, and show superior reconstruction quality, especially from noisy data and a small number of projections.

  2. Detection of hepatic tumor by means of single photon emission computed tomography, Gray scale ultrasonography, and computed tomography

    International Nuclear Information System (INIS)

    We have studied the hepatic tumor detection by single photon emission computed tomography (SPECT) using rotatory chair and gamma camera. SPECT were taken by multiple section slice not only in transaxial view, but also in frontal and sagital. The results were superior in detectability to conventional liver scintiphoto (CLS). In cases of obstructive jaundice, ultrasonography (US) and/or computed axial tomography (CAT) should be taken before SPECT, because there are various probabilities of evaluation like as false positive by means of SPECT. Simultaneous interpretation of SPECT, US, and CAT was more helpful than independent interpretation

  3. Computed tomography of cystic pancreatic fibrosis

    International Nuclear Information System (INIS)

    The computer tomographic appearances of atrophic and lipomatous degeneration of the pancreas in cystic pancreatic fibrosis are described. CT exploration of the pancreas in recommended, particularly in differential diagnostic aspects of cystic fibrosis. (orig.)

  4. Cost-effectiveness of PET and PET/Computed Tomography

    DEFF Research Database (Denmark)

    Gerke, Oke; Hermansson, Ronnie; Hess, Søren;

    2015-01-01

    measure by means of incremental cost-effectiveness ratios when considering the replacement of the standard regimen by a new diagnostic procedure. This article discusses economic assessments of PET and PET/computed tomography reported until mid-July 2014. Forty-seven studies on cancer and noncancer...

  5. Micro-computed tomography: an alternative method for shark ageing.

    Science.gov (United States)

    Geraghty, P T; Jones, A S; Stewart, J; Macbeth, W G

    2012-04-01

    Micro-computed tomography (microCT) produced 3D reconstructions of shark Carcharhinus brevipinna vertebrae that could be virtually sectioned along any desired plane, and upon which growth bands were readily visible. When compared to manual sectioning, it proved to be a valid and repeatable means of ageing and offers several distinct advantages over other ageing methods. PMID:22497384

  6. Radiation dosimetry of computed tomography x-ray scanners

    International Nuclear Information System (INIS)

    This report describes the development and application of the methods employed in National Radiation Laboratory (NRL) surveys of computed tomography x-ray scanners (CT scanners). It includes descriptions of the phantoms and equipment used, discussion of the various dose parameters measured, the principles of the various dosimetry systems employed and some indication of the doses to occupationally exposed personnel

  7. Multidetector computed tomography of jaw lesions in children and adolescents

    International Nuclear Information System (INIS)

    Full text: Jaw lesions in paediatric and adolescent population are uncommon and can arise in odontogenic or non-odontogenic tissues. With the advent of multidetector computed tomography (MDCT), algorithm for imaging jaw lesions has changed dramatically. This pictorial essay describes the imaging appearance of commonly encountered jaw lesions in children and adolescents with emphasis on MDCT findings

  8. Paradigm of pretest risk stratification before coronary computed tomography

    DEFF Research Database (Denmark)

    Jensen, Jesper Møller; Øvrehus, Kristian; Nielsen, Lene H;

    2009-01-01

    BACKGROUND: The optimal method of determining the pretest risk of coronary artery disease as a patient selection tool before coronary multidetector computed tomography (MDCT) is unknown. OBJECTIVE: We investigated the ability of 3 different clinical risk scores to predict the outcome of coronary ...

  9. Computed Tomography Features of Spontaneously Perforated Pyometra: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Chan, K.S.; Tan, C.K.; Mak, C.W.; Chia, C.C.; Kuo, C.Y.; Yu, W.L. [Chi-Mei Medical Center, Tainan, Taiwan (China). Depts. of Intensive Care Medicine, Radiology, Obstetrics and Gynecology, and Surgery

    2006-03-15

    Spontaneous perforation of pyometra is an extremely rare emergent gynecologic disease. We report a 73-year-old woman with a spontaneously perforated pyometra presenting with acute abdomen in the emergency department. A dedicated computed tomography examination of the abdominal and pelvic regions revealed the diagnosis. The patient recovered well after surgical intervention and antibiotic treatment.

  10. Computed tomography of the human developing anterior skull base

    NARCIS (Netherlands)

    J. van Loosen (J.); A.I.J. Klooswijk (A. I J); D. van Velzen (D.); C.D.A. Verwoerd (Carel)

    1990-01-01

    markdownabstractAbstract The ossification of the anterior skull base, especially the lamina cribrosa, has been studied by computed tomography and histopathology. Sixteen human fetuses, (referred to our laboratory for pathological examination after spontaneous abortion between 18 and 32 weeks of ge

  11. Tracheo-oesophageal fistula diagnosed with multidetector computed tomography.

    LENUS (Irish Health Repository)

    Hodnett, Pa

    2009-04-01

    This case highlights important issues in investigation of patients with suspected tracheo-oesophageal fistula including the value of multidetector computed tomography, the importance of thorough imaging evaluation when high clinical suspicion of tracheo-oesophageal fistula exists and the value of close interaction between radiologists and intensive care physicians in the investigation of these patients.

  12. An Easily Assembled Laboratory Exercise in Computed Tomography

    Science.gov (United States)

    Mylott, Elliot; Klepetka, Ryan; Dunlap, Justin C.; Widenhorn, Ralf

    2011-01-01

    In this paper, we present a laboratory activity in computed tomography (CT) primarily composed of a photogate and a rotary motion sensor that can be assembled quickly and partially automates data collection and analysis. We use an enclosure made with a light filter that is largely opaque in the visible spectrum but mostly transparent to the near…

  13. RADIAL COMPUTED TOMOGRAPHY OF AIR CONTAMINANTS USING OPTICAL REMOTE SENSING

    Science.gov (United States)

    The paper describes the application of an optical remote-sensing (ORS) system to map air contaminants and locate fugitive emissions. Many ORD systems may utilize radial non-overlapping beam geometry and a computed tomography (CT) algorithm to map the concentrations in a plane. In...

  14. Computed Tomography-Enhanced Anatomy Course Using Enterprise Visualization

    Science.gov (United States)

    May, Hila; Cohen, Haim; Medlej, Bahaa; Kornreich, Liora; Peled, Nathan; Hershkovitz, Israel

    2013-01-01

    Rapid changes in medical knowledge are forcing continuous adaptation of the basic science courses in medical schools. This article discusses a three-year experience developing a new Computed Tomography (CT)-based anatomy curriculum at the Sackler School of Medicine, Tel Aviv University, including describing the motivations and reasoning for the…

  15. Computed tomography in the diagnosis of the lumbar disc herniation

    Energy Technology Data Exchange (ETDEWEB)

    Iwakura, Yuichiro (Yatsushiro General Hospital, Kumamoto (Japan)); Hayashi, Yasuo; Suzuki, Mutsuaki; Uemura, Mitsuharu; Fukuda, Kazuyuki; Koito, Hirofumi

    1984-06-01

    In this study, effectiveness of computed tomography (CT) in diagnosing lumbar disc herniation was evaluated. Twenty CT examinations which were interpreted as positive for a herniated disc, and were comfirmed by myelography, were reviewed. In 19 patients, CT demonstrated posterior protrusion of the disc but in one normal disc. Three typical cases were described. This study suggests that CT accurately demonstrates lumbar disc herniation.

  16. The role of computed tomography in modern paediatric uroradiology

    International Nuclear Information System (INIS)

    Computed tomography (CT) has developed a well-recognised role within paediatric uroradiology, especially in imaging of trauma, malignancy (in particular Wilms' tumour), atypical infection, and congenital urogenital abnormalities. CT can also be used for problem solving in nephrolithiasis and renal transplant assessment. These applications are illustrated and discussed, with an emphasis on particular information that can be gained from the CT study

  17. Improvement of reconstructed image quality of neutron computed tomography

    International Nuclear Information System (INIS)

    Neutron computed tomography has been studied. Endeavor has been given to obtain high image quality of CT reconstruction. Film method is comparatively preferred to dynamic neutron TV one. Some models for nuclear fuels have been reconstructed. Dispersion of 300 μm Eu-particles in TiO2 pellets, which simulate PuO2/UO2 nuclear fuel, have been reconstructed

  18. Geometrical metrology on silicone rubber by computed tomography

    DEFF Research Database (Denmark)

    Müller, Pavel; Pacurar, Ramona Alexandra; De Chiffre, Leonardo;

    2011-01-01

    Computed tomography (CT) represents a suitable measuring technique for investigation of deformable materials, since no forces are developed on the part during scanning. As for any other measuring instruments, the traceability of the CT scanners needs to be assured. An investigation on geometrical...

  19. Bone densitometry in healthy cats by quantitative computed tomography

    International Nuclear Information System (INIS)

    The radiodensity of the trabecular bone of the lumbar vertebrae in 16 healthy adult cats was studied using quantitative computed tomography (QCT). The average radiodensity of the trabecular bone of the second lumbar vertebra was 436.1 +- 42.1 Hounsfield units. However, there was a nonhomogeneous radiodensity distribution of the vertebral body. (author)

  20. Coronary computed tomography - present status and future directions

    NARCIS (Netherlands)

    Apfaltrer, P.; Schoepf, U. J.; Vliegenthart, R.; Rowe, G. W.; Spears, J. R.; Fink, C.; Nance, J. W.

    2011-01-01

    The use of coronary computed tomography angiography (cCTA) is growing rapidly, in large part because of fast-paced technical innovations that have increased diagnostic accuracy while providing new opportunities for radiation dose reduction. cCTA using recent generation CT scanners has been repeatedl

  1. COMPUTED TOMOGRAPHY IN HYDATID CYST OF THE ORBIT

    Directory of Open Access Journals (Sweden)

    K. Abbassioun

    1982-07-01

    Full Text Available Two cases of hydatid cysts of the orbit causing unilateral exophthalmos are reported. Diagnosis were suspected by means of computed tomography (CT and confirmed at Operation. CT changes are described and its value in diagnosis of this lesion particularly in the endemic areas is stressed.

  2. Computer tomography in Caisson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Horvath, F.; Csobaly, S.

    1981-07-01

    Computer tomography was performed on 20 patients with the early stages of Caisson osteoarthropathy, as well as in other patients with chronic bone infarcts. From their results the authors have formed the opinion that CT is valuable, not only in the diagnosis of early cases, but that it can provide significant information concerning the osteopathy and bone infarcts.

  3. Tolerance Verification of an Industrial Assembly using Computed Tomography

    DEFF Research Database (Denmark)

    Stolfi, Alessandro; De Chiffre, Leonardo; Regi, Francesco

    2016-01-01

    This paper reports on results of tolerance verification of a multi-material assembly by using Computed Tomography (CT). The workpiece comprises three parts which are made out of different materials. Five different measurands were inspected. The calculation of measurement uncertainties was attempt...

  4. Computed tomography of the gastro-intestinal tract : its value

    International Nuclear Information System (INIS)

    The subject discussed include indications and accuracy of CT - computed tomography, technical considerations, common pitfalls in CT interpretation, parameters for CT evaluation, benign lesions, double halo and target signs, hyperattenuated, inflammatory bowel disease, intestinal ischaemia, primary adenocarcinoma of the GIT, lymphoma and leiomyosarcoma (3 refs.)

  5. Computed Tomography Structural Lung Changes in Discordant Airflow Limitation

    NARCIS (Netherlands)

    F.A.A. Mohamed Hoesein (Firdaus); P.A. de Jong (Pim); J.W.J. Lammers; W.P. Mali (Willem); M. Schmidt (Michael); H.J. de Koning (Harry); C.M. van der Aalst (Carlijn); M. Oudkerk (Matthijs); R. Vliegenthart (Rozemarijn); B.T.J. van Ginneken (Berbke); E.M. van Rikxoort (Eva); P. Zanen (Pieter)

    2013-01-01

    textabstractBackground:There is increasing evidence that structural lung changes may be present before the occurrence of airflow limitation as assessed by spirometry. This study investigated the prevalence of computed tomography (CT) quantified emphysema, airway wall thickening and gas trapping acco

  6. Computed tomography structural lung changes in discordant airflow obstruction

    NARCIS (Netherlands)

    Hoesein, F.A.A.M.; Jong, P.A. de; Lammers, J.W.; Mali, W.P.Th.; Schmidt, M.; Koning, H.J. de; Aalst, C. van der; Oudkerk, M.; Vliegenthart, R.; Ginneken, B. van; Rikxoort, E.M. van; Zanen, P.

    2013-01-01

    Background: There is increasing evidence that structural lung changes may be present before the occurrence of airflow limitation as assessed by spirometry. This study investigated the prevalence of computed tomography (CT) quantified emphysema, airway wall thickening and gas trapping according to cl

  7. Computed Tomography Structural Lung Changes in Discordant Airflow Limitation

    OpenAIRE

    Firdaus A A Mohamed Hoesein; de Jong, Pim A; Lammers, Jan-Willem J; Willem Pthm Mali; Michael Schmidt; de Koning, Harry J.; Carlijn van der Aalst; Matthijs Oudkerk; Rozemarijn Vliegenthart; Bram van Ginneken; van Rikxoort, Eva M; Pieter Zanen

    2013-01-01

    BACKGROUND: There is increasing evidence that structural lung changes may be present before the occurrence of airflow limitation as assessed by spirometry. This study investigated the prevalence of computed tomography (CT) quantified emphysema, airway wall thickening and gas trapping according to classification of airflow limitation (FEV1/FVC 70%; group 2LLN; and group 370% but FEV1

  8. Evaluation by computed tomography in premature and newborn infants

    International Nuclear Information System (INIS)

    By means of cranio-cerebral computed tomography hypoxic brain damage of varying degrees and different types may be demonstrated in premature infants and high-risk newborns. Paraventricular leucomalacia of varying extent up to porencephalic defects are found, as well as cortical infarctions, hemorrhage into brain tissue or ventricles, cerebral atrophy, developing hydrocephalus and congenital anomalies. (orig.)

  9. Position emission tomography with or without computed tomography in the primary staging of Hodgkin's lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Jakobsen, Annika Loft; Hansen, Mads;

    2006-01-01

    In order to receive the most appropriate therapy, patients with Hodgkin's lymphoma (HL) must be accurately stratified into different prognostic staging groups. Computed tomography (CT) plays a pivotal role in the conventional staging. The aim of the present study was to investigate the value of...

  10. Correction of polychromatic radiogram errors in computer tomography images

    International Nuclear Information System (INIS)

    The polychromatic errors in radiograms obtained by computer tomography are corrected by an image processing facility with e.g. image storage equipment. In the computer tomogram itself no correction of the original projection data is performed. From it there is derived an error image and subtracted from the original image in order to get a corrected image. This is done by assessing the projected data of the biological tissues and calculating therefrom error-projection data by means of mathematical methods. (RW)

  11. Multi-scale analysis of lung computed tomography images

    OpenAIRE

    Gori, I.; Bagagli, F.; Fantacci, M. E.; Martinez, A. Preite; Retico, A.; De Mitri, I.; Donadio, S.; Fulcheri, C.; Gargano, G; Magro, R.; Santoro, M; Stumbo, S

    2009-01-01

    A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on...

  12. Computed tomography of the temporal horns at Alzheimer's disease

    International Nuclear Information System (INIS)

    In the literature there are different opinions referring to the involvement of the temporal lobes or horns at Alzheimer's disease. Conventionally computed tomogram of the head does not include the temporal horn in its full length. A simple method to demonstrate the temporal horns after cranial computer tomography is described. It allows the evaluation of temporal lobe and temporal horn if questionable alterations at Alzheimer's disease are to be discussed. (orig.)

  13. Global seismic tomography and modern parallel computers

    Directory of Open Access Journals (Sweden)

    A. Piersanti

    2006-06-01

    Full Text Available A fast technological progress is providing seismic tomographers with computers of rapidly increasing speed and RAM, that are not always properly taken advantage of. Large computers with both shared-memory and distributedmemory architectures have made it possible to approach the tomographic inverse problem more accurately. For example, resolution can be quantified from the resolution matrix rather than checkerboard tests; the covariance matrix can be calculated to evaluate the propagation of errors from data to model parameters; the L-curve method can be applied to determine a range of acceptable regularization schemes. We show how these exercises can be implemented efficiently on different hardware architectures.

  14. Single-photon emission computed tomography/computed tomography in abdominal diseases.

    Science.gov (United States)

    Schillaci, Orazio; Filippi, Luca; Danieli, Roberta; Simonetti, Giovanni

    2007-01-01

    Single-photon emission computed tomography (SPECT) studies of the abdominal region are established in conventional nuclear medicine because of their easy and large availability, even in the most peripheral hospitals. It is well known that SPECT imaging demonstrates function, rather than anatomy. It is useful in the diagnosis of various disorders because of its ability to detect changes caused by disease before identifiable anatomic correlates and clinical manifestations exist. However, SPECT data frequently need anatomic landmarks to precisely depict the site of a focus of abnormal tracer uptake and the structures containing normal activity; the fusion with morphological studies can furnish an anatomical map to scintigraphic findings. In the past, software-based fusion of independently performed SPECT and CT or magnetic resonance images have been demonstrated to be time consuming and not useful for routine clinical employment. The recent development of dual-modality integrated imaging systems, which provide SPECT and CT images in the same scanning session, with the acquired images co-registered by means of the hardware, has created a new scenario. The first data have been mainly reported in oncology patients and indicate that SPECT/CT is very useful because it is able to provide further information of clinical value in several cases. In SPECT studies of abdominal diseases, hybrid SPECT/CT can play a role in the differential diagnosis of hepatic hemangiomas located near vascular structures, in precisely detecting and localizing active splenic tissue caused by splenosis in splenectomy patients, in providing important information for therapy optimization in patients submitted to hepatic arterial perfusion scintigraphy, in accurately identifying the involved bowel segments in patients with inflammatory bowel diseases, and in correctly localizing the bleeding sites in patients with gastrointestinal bleeding. PMID:17161039

  15. Cranial computed tomography in infancy and childhood

    International Nuclear Information System (INIS)

    A large number of pediatric cases have been accumulated and categorized according to congenital abnormalities, trauma, hydrocephalus, tumors, and infection. Each category contains background material accompanied by computed-tomographic (CT) illustrations and a related discussion. The material is derived from 6,000 CT scans performed at Children's Hospital National Medical Center in Washington, DC since 1973

  16. Estimation of lung growth using computed tomography

    NARCIS (Netherlands)

    P.A. de Jong (Pim); Y. Nakano (Yasutaka); M.H. Lequin (Maarten); P.J.F.M. Merkus (Peter); H.A.W.M. Tiddens (Harm); J.C. Hogg; H.O. Coxson (Harvey)

    2003-01-01

    textabstractAnatomical studies suggest that normal lungs grow by rapid alveolar addition until about 2 yrs of age followed by a gradual increase in alveolar dimensions. The aim of this study was to examine the hypothesis that normal lung growth can be monitored by computed tomograp

  17. Mycosis fungoides: manifestations on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shapeero, L.G.; Young, S.W.

    1983-07-01

    Mtcosis fungoides is a malignant lymphoma of the skin that causes intense erythema, plaques, edema, and induration. The primary computed tomographic findings of mycosis fungoides, i.e., skin thickening, tumorous infiltration, edema of the soft tissues, and lymphadenopathy, are presented in two patients.

  18. Computer tomography of large dust clouds in complex plasmas

    International Nuclear Information System (INIS)

    The dust density is a central parameter of a dusty plasma. Here, a tomography setup for the determination of the three-dimensionally resolved density distribution of spatially extended dust clouds is presented. The dust clouds consist of micron-sized particles confined in a radio frequency argon plasma, where they fill almost the entire discharge volume. First, a line-of-sight integrated dust density is obtained from extinction measurements, where the incident light from an LED panel is scattered and absorbed by the dust. Performing these extinction measurements from many different angles allows the reconstruction of the 3D dust density distribution, analogous to a computer tomography in medical applications

  19. Cranial computed tomography in psychiatry. Kraniale Computertomographie in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Falkai, P. (Rheinische Landes- und Hochschulklinik Duesseldorf, Psychiatrische Klinik der Heinrich-Heine-Universitaet (Germany)); Bogerts, B. (Rheinische Landes- und Hochschulklinik Duesseldorf, Psychiatrische Klinik der Heinrich-Heine-Universitaet (Germany))

    1993-08-13

    Computed tomography has gained importance as a diagnostic tool in psychiatry to exclude structural brain pathology, but has passed on its role in research to magnetic resonance tomography. It helps to distinguish between senile dementia of Alzheimer type and multi-infarct dementia. The enlargement of the ventricular system and cortical sulci is well established in schizophrenic and affective psychosis. Some alcohol addicts show a considerable degree of cerebral atrophy, only exceeded by demented patients, but this condition is potentially reversible. To screen psychiatric patients by CT is recommendable, as 2-10% of hospitalized psychiatric patients have structural brain disease. (orig.)

  20. Flip-flop phenomenon in systemic sclerosis on fluorodeoxyglucose positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Systemic sclerosis (SSc) is a rare autoimmune disease, which may affect multiple organ systems. Fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) can demonstrate the degree and anatomical extent of involvement in the entire body and coexisting malignancies in connective tissue diseases. We present a case of SSc with an increased 18F-FDG uptake in the cutaneous and subcutaneous tissues even higher than the neighboring skeletal muscles (“flip-flop phenomenon,” that is, an increased 18F-FDG uptake in the skin but a decreased 18F-FDG uptake in the skeletal muscles)

  1. Assessment of asthmatic inflammation using hybrid fluorescence molecular tomography-x-ray computed tomography

    Science.gov (United States)

    Ma, Xiaopeng; Prakash, Jaya; Ruscitti, Francesca; Glasl, Sarah; Stellari, Fabio Franco; Villetti, Gino; Ntziachristos, Vasilis

    2016-01-01

    Nuclear imaging plays a critical role in asthma research but is limited in its readings of biology due to the short-lived signals of radio-isotopes. We employed hybrid fluorescence molecular tomography (FMT) and x-ray computed tomography (XCT) for the assessment of asthmatic inflammation based on resolving cathepsin activity and matrix metalloproteinase activity in dust mite, ragweed, and Aspergillus species-challenged mice. The reconstructed multimodal fluorescence distribution showed good correspondence with ex vivo cryosection images and histological images, confirming FMT-XCT as an interesting alternative for asthma research.

  2. X-ray computed tomography of PEM fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Pfrang, Andreas; Veyret, Damien; Tsotridis, Georgios [Commission of the European Communities, Petten (Netherlands). Joint Reseach Centre, Inst. for Energy; Janssen, Gaby [Energy Research Centre of the Netherlands ECN, Petten (Netherlands). Dept. of Hydrogen and Clean Fossil Fuels

    2010-07-01

    Proton exchange membrane (PEM) fuel cells were investigated by 3D x-ray computed tomography at a voxel size of 0.7 {mu}m. It is shown that this lab-based technique is not only suitable for the investigation of gas diffusion layers (GDL) as well as the investigation of membrane electrode assemblies (MEA), but also allows the calculation of macroscopic physical properties. The resolution of computed tomography is clearly sufficient to image the carbon fiber structure of gas diffusion layers in the as received GDLs as well as GDLs integrated into membrane electrode assemblies. It is also possible to visualize the catalyst layer within the MEA, which allows the investigation of layer thickness and structural defects on a larger scale than with conventional techniques. The macroscopic effective thermal conductivities of the gas diffusion layers were computed based on the 3D GDL structure reconstructed from tomography data to produce more reliable input data for fuel cell modeling. The computation was carried out by solving the energy equation considering a pure thermal conduction problem. The computations show - in agreement with the expectation and experimental data - that the through-plane thermal conductivities are lower than the in-plane thermal conductivities. (orig.)

  3. Comparison of radiation absorbed dose in target organs in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography and computed tomography

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2009-12-01

    Full Text Available "nBackground and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT and computed tomography (CT."nMaterials and Methods: Thermoluminescent dosimeters (TLD were implanted in 14 sites of RANDO phantom to measure average tissue absorbed dose in thyroid gland, parotid glands, submandibular glands, sublingual gland, lenses and buccal skin. The Promax (PLANMECA, Helsinki, Finland unit was selected for Panoramic, conventional linear tomography and cone beam computed tomography examinations and spiral Hispeed/Fxi (General Electric,USA was selected for CT examination. The average tissue absorbed doses were used for the calculation of the equivalent and effective doses in each organ."nResults: The average absorbed dose for Panoramic ranged from 0.038 mGY (Buccal skin to 0.308 mGY (submandibular gland, linear tomography ranged from 0.048 mGY (Lens to 0.510 mGY (submandibular gland,CBCT ranged from 0.322 mGY (thyroid glad to 1.144 mGY (Parotid gland and in CT ranged from 2.495 mGY (sublingual gland to 3.424 mGY (submandibular gland. Total effective dose in CBCT is 5 times greater than Panoramic and 4 times greater than linear tomography, and in CT, 30 and 22 times greater than Panoramic and linear tomography, respectively. Total effective dose in CT is 6 times greater than CBCT."nConclusion: For obtaining 3-dimensional (3D information in maxillofacial region, CBCT delivers the lower dose than CT, and should be preferred over a medical CT imaging. Furthermore, during maxillofacial imaging, salivary glands receive the highest dose of radiation.

  4. Comparison of computed tomography and conventional tomography of tumors located in the nasopharynx and paranasal sinuses

    International Nuclear Information System (INIS)

    The value of conventional tomography for the clinical evaluation of tumors located in the nasopharynx and paranasal sinuses has been well established. The present study analyzed the potential improvement of the preoperative evaluation of the extent of those tumors by computed tomography. Conventional tomography was performed with polycycloidal movement. An initial comparison was made using a normal skull phantom. This facilitated the comparison of both diagnostic methods for the recognition of osseous structures. The evaluation of the clinical efficiency of both diagnostic modalities was performed with various cases of early and late tumors involving bony and soft tissue structures of the skull. The correlation of the information obtained by the radiographic methods with the extent of the tumor seen at the operation were the final criteria. Follow-up examinations after radiotherapy wereemployed in several cases. The results and implications of this study are presented. (orig.) 891 MG/orig. 892 MB

  5. Coordinate Metrology by Traceable Computed Tomography

    OpenAIRE

    Müller, Pavel; De Chiffre, Leonardo; Hansen, Hans Nørgaard; Cantatore, Angela

    2013-01-01

    Røntgen computer tomografi (CT) er en måleteknik som er blevet en vigtig teknologi i produktionsmiljøer gennem de seneste år. På grund af et antal fordele ved CT, eksempelvis sammenlignet med koordinatmålemaskiner (CMM’er), er CT på det seneste blevet udbredt indenfor produktions- og koordinatmåleteknik og er aktuelt ved at blive en mere og mere vigtig måleteknik til dimensionsmålinger. Dette er primært på grund af at man med CT relativt hurtigt kan visualisere en komplet tredimensionel model...

  6. Computed tomography in congenital ocular motor apraxia

    Energy Technology Data Exchange (ETDEWEB)

    Eda, I.; Takashima, S.; Kitahara, T.; Ohno, K.; Takeshita, K.

    1984-09-01

    Unusual computed tomographic findings were observed in four patients with congenital ocular motor apraxia (COMA). These (CT) findings were characteristic in the posterior cranial fossa, with a dilated or deformed shape and size of the fourth ventricle, particularly its upper portion. One case revealed partial agenesis of the cerebellar vermis. It was suggested that the four patients subjected to CT showed abnormal topography of the cerebellar vermis or the brain stem. We postulate that these CT findings in COMA may have an important role in its pathogenesis.

  7. Computed tomography of the elbow joint

    Energy Technology Data Exchange (ETDEWEB)

    Burmester, E.; Gmelin, E.; Mendoza, A.S.

    1985-12-01

    An essential pre-condition for the interpretation of computer tomographs of the elbow joint is a knowledge of the normal anatomy. The complexity of the joint requires a definite protocol for the examination, since only in this way it is possible to distinguish all anatomical structures and pathological processes. A clinical example is used to show that CT of the elbow joint is superior to all other radiographic methods for demonstrating osteochondritis dissecans. It is therefore an important additional method for demonstrating the elbow joint.

  8. Intramammary incidental findings on staging computer tomography

    Energy Technology Data Exchange (ETDEWEB)

    Surov, Alexey, E-mail: alex.surow@medizin.uni-halle.de [Department of Radiology, Martin-Luther-University Halle-Wittenberg, Ernst-Grubestr. 40, 06097 Halle (Germany); Fiedler, Eckhard [Department of Dermatology, Martin-Luther-University Halle-Wittenberg, Ernst-Grubestr. 40, 06097 Halle (Germany); Wienke, Andreas [Department of Medical Statistics, Martin-Luther-University Halle-Wittenberg, Ernst-Grubestr. 40, 06097 Halle (Germany); Holzhausen, Hans-Jürgen [Department of Pathology, Martin-Luther-University Halle-Wittenberg, Ernst-Grubestr. 40, 06097 Halle (Germany); Spielmann, Rolf-Peter; Behrmann, Curd [Department of Radiology, Martin-Luther-University Halle-Wittenberg, Ernst-Grubestr. 40, 06097 Halle (Germany)

    2012-09-15

    Purpose: Incidental findings are a common feature in computer tomographic examinations of the chest. Breast incidentalomas, however, were described only sporadically. The purpose of this study was to evaluate retrospectively incidental breast findings and to compare radiological features of benign and malignant breast lesions. Materials and methods: From January 2006 to December 2010 a total of 8105 computer tomographic examinations were performed at our institution. In 89 patients incidental breast lesions were diagnosed. 64 of the identified patients were referred for further clinical, radiological, and hystopathological examination. All patients were female with a median age of 62 years, range 39–82 years. Results: A total of 98 breast lesions were identified in the 64 patients. The mean size was 12.0 ± 8.0 mm. Primary breast carcinoma was identified in 9, breast metastases in 27, and benign findings in 28 patients. Malignant lesions demonstrated more often marked enhancement and showed a higher density compared with benign lesions. Benign findings were more often lobular in shape and had spiculated margins. Most of the breast metastases were round or oval in shape with circumscribed margins and marked homogenous enhancement. There was no significant difference between the breast cancer and benign findings groups in the characteristics of the lesions. Conclusion: The breast is a very important region and should be carefully evaluate on chest CT. There are no certain radiological criteria to differentiate between malignant and benign breast lesions on CT. Therefore all breast incidentalomas should be evaluated by further radiological/histological investigations.

  9. 21 CFR 892.1750 - Computed tomography x-ray system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Computed tomography x-ray system. 892.1750 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1750 Computed tomography x-ray system. (a) Identification. A computed tomography x-ray system is a diagnostic x-ray system intended...

  10. Intracranial calcification on paediatric computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kendall, B.; Cavanagh, N.

    1986-07-01

    An analysis of the computed tomograms of 18000 children examined consecutively form the basis of an assessment of the diagnostic significance of intracranial calcification. The low incidence of physiological calcification in the pineal and choroid of about 2% up to the age of 8 years, but increasing 5-fold by the age of 15 years, is confirmed. Pathological calcification occurred in 1.6%, the commonest causes being neoplasms (43%), neuroectodermal syndromes (20%) and infections (12%). Diffuse basal ganglia calcification (15%) bore little relation to the diverse clinical symptomatology, and routine biochemical studies showed a disorder of metabolism to be present in only 6 cases. Calcification has not been previously noted in acute haemorrhagic leukoencephalitis, Pertussis or Cocksackie encephalitis, infantile neuraxonal dystrophy, Marinesco-Sjoegren syndrome or in the basal ganglia in neurofibromatosis.

  11. Computed tomography in staging of oesophageal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Salonen, O.; Kivisaari, L.; Standertskjoeld-Nordenstam, C.G.; Somer, K.; Virkkunen, P.

    1987-01-01

    The computed tomographic (CT) findings in 45 patients with histologically proved oesophageal carcinoma are reviewed. In 20 of these patients the CT findings were correlated with findings at surgery (19 patients) or autopsy (1 patient). Correlation analysis showed that the accuracy of CT in assessing both invasion of adjacent organs and mediastinal and abdominal lymph node involvement is limited. 25 patients were considered inoperable. In 15 of these conclusion was based on CT findings of distant metastases (14 patients) or definite local invasion (1 patient). 10 patients were inoperable for other reasons (general health condition). The value of CT was found to be in detecting distant metastases, thus avoiding unnecessary radical surgery. It is not a reliable way of defining the primary tumour.

  12. Significance of triplane computed tomography in otolaryngology

    International Nuclear Information System (INIS)

    The authors obtained direct sagittal CT scans of the head using a new method for positioning the head of patient in sitting position. Direct sagittal scans are more useful than computed rearranged scans in a better spatial and density resolution. The triplane CT (axial, coronal, and sagittal CT) greatly improves three dimentional recognition of the intracranial and facial structures and the extent of the lesion. A series of patients with various nasal and oropharyngeal tumors was examined with the triplane CT. The advantages of direct sagittal scans are (1) the recognition of localization and extension of the lesion. (2) the evaluation of the extent of the deep facial and nasopharygeal tumors, especially in the intracranial and intraorbital regions. (3) the more accurate determination of staging of the maxillary cancer. (author)

  13. Initial water quantification results using neutron computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heller, A.K. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)], E-mail: axh174@psu.edu; Shi, L.; Brenizer, J.S.; Mench, M.M. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)

    2009-06-21

    Neutron computed tomography is an important imaging tool in the field of non-destructive testing and in fundamental research for many engineering applications. Contrary to X-rays, neutrons can be attenuated by some light materials, such as hydrogen, but can penetrate many heavy materials. Thus, neutron computed tomography is useful in obtaining important three-dimensional information about a sample's interior structure and material properties that other traditional methods cannot provide. The neutron computed tomography system at Pennsylvania State University's Radiation Science and Engineering Center is being utilized to develop a water quantification technique for investigation of water distribution in fuel cells under normal conditions. A hollow aluminum cylinder test sample filled with a known volume of water was constructed for purposes of testing the quantification technique. Transmission images of the test sample at different angles were easily acquired through the synthesis of a dedicated image acquisition computer driving a rotary table controller and an in-house developed synchronization software package. After data acquisition, Octopus (version 8.2) and VGStudio Max (version 1.2) were used to perform cross-sectional and three-dimensional reconstructions of the sample, respectively. The initial reconstructions and water quantification results are presented.

  14. Initial water quantification results using neutron computed tomography

    International Nuclear Information System (INIS)

    Neutron computed tomography is an important imaging tool in the field of non-destructive testing and in fundamental research for many engineering applications. Contrary to X-rays, neutrons can be attenuated by some light materials, such as hydrogen, but can penetrate many heavy materials. Thus, neutron computed tomography is useful in obtaining important three-dimensional information about a sample's interior structure and material properties that other traditional methods cannot provide. The neutron computed tomography system at Pennsylvania State University's Radiation Science and Engineering Center is being utilized to develop a water quantification technique for investigation of water distribution in fuel cells under normal conditions. A hollow aluminum cylinder test sample filled with a known volume of water was constructed for purposes of testing the quantification technique. Transmission images of the test sample at different angles were easily acquired through the synthesis of a dedicated image acquisition computer driving a rotary table controller and an in-house developed synchronization software package. After data acquisition, Octopus (version 8.2) and VGStudio Max (version 1.2) were used to perform cross-sectional and three-dimensional reconstructions of the sample, respectively. The initial reconstructions and water quantification results are presented.

  15. Role of computed tomography in pancreatic trauma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Hee; Kim, Ki Whang; Lee, Jong Tae; Oh, Sei Jung [College of Medicine, Yonsei University, Seoul (Korea, Republic of)

    1991-03-15

    At Yonsei University Hospital from January 1984 to August 1990, computed tomographic (CT) scans of 13 patients with surgically proven pancreatic injuries after blunt abdominal trauma, including 6 pancreatic lacerations or contusions, 6 pancreatic fractures, and one post-traumatic pseudocyst, were retrospectively reviewed to determine the role and accuracy of the CT in evaluating pancreatic injury. CT can document gross pancreatic injury by showing focal or diffuse enlargement (1), area of diminished attenuation (3), separation (5), focal hematoma (2), and peripancreatic change, including peripancreatic hematoma (2), fluid collection (11), perirenal fascial thickening (10), omental and mesenteric change (5), and bowel change (2). CT correctly diagnosed pancreatic fracture in 5 cases, post-raumatic pseudocyst in 1 case, and pancreatic laceration in 3 cases in 9 of these patients. There were 4 false negative diagnoses, including 3 pancreatic lacerations and 1 pancreatic fracture. A CT is of pancreatic trauma could be difficult to diagnosis in patients who are scanned within 24 hrs after an injury or to distinguish a motion or streak artifact caused by a nasogastric tube or air-oral contrast fluid level in the stomach.

  16. Didactics and training in cardiovascular computed tomography angiography.

    Science.gov (United States)

    Bhojraj, Sanjay D; Al-Mallah, Mouaz H

    2009-01-01

    As the role of cardiovascular computed tomography angiography (CCTA) is further expanded through research, the use of this technology will expand as a result of demand both from medical professionals and the public. To ensure a standardized quality of interpretation of these scans in the face of an increased demand for physicians qualified to interpret these studies, the Society of Cardiovascular Computed Tomography, along with several other professional societies, has proposed a didactic curriculum for the study of CCTA. This review highlights the currently proposed didactic curriculum for the study of CCTA, examines current trends in training for both medical trainees and physicians in practice, and proposes future directions for the study of CCTA. PMID:19203747

  17. Computed tomography of coronary artery anomaly - case report

    International Nuclear Information System (INIS)

    Background: Anomalies of coronary vessels can be described as varies group of congenital heart disease, which can have different level of clinical manifestation and changeable pathophysiological mechanisms. Diagnosis and imaging of vessel course is essential before percutaneous angioplasty intervention and coronary artery bypass grafting as well as before implantation of artificial valve. Case Report: Patient with cardiologic history, previously percutaneous intervention were performed and left circumflex coronary artery were assessed as occluded. Computed tomography revealed anomalous origin of patent circumflex branch arising from right Valsava sinus. Conclusions: Selective percutaneus coronary angiography is challenging in case of coronary anomalies, there are only few indirect symptoms of anomalies. The advantage of computed tomography over classic coronarography is visibility of all patent coronary vessels after single administration of contrast medium. It is possible to describe its anatomic relations, evaluation of walls and its changes

  18. High Resolution Muon Computed Tomography at Neutrino Beam Facilities

    CERN Document Server

    Suerfu, Burkhant

    2015-01-01

    X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires higher resolution in the muon spectrometer to resolve the image. The variance of the measured muon momentum reaches a minimum and then increases with increasing muon momentum. The impact of the increase in variance is to require a higher integrated muon flux to reduce fluctuations. The flux requirements and level of contrast needed for high resolution muon computed tomography are well matched to the muons produced in the pio...

  19. Computed tomography of the adrenals in patients with tuberculosis

    International Nuclear Information System (INIS)

    We evaluated the adrenals of individuals without tuberculosis (group 1 - G1) and with tuberculosis (group 2 - G2) using computed tomography. The antero-posterior length, the thickness, and the longitudinal length of the adrenals were compared in G1 and G2. The duration of the disease, the occurrence of morphologic abnormalities in G2, the distribution according to sex, age and skin color were also studied. There was difference in the antero-posterior length and thickness of right adrenal between G1 and G2. A higher prevalence of white skin male individuals was observed in G2. There was no association between duration of the disease and the occurrence of morphologic abnormalities in G2. A higher occurrence of adrenal enlargement was observed in G2. The main computed tomography findings in patients with tuberculosis were enlargement of the adrenal without calcification, enlargement of the adrenal with punctiform calcifications, and residual calcification of the adrenal. (author)

  20. Didactics and training in cardiovascular computed tomography angiography.

    Science.gov (United States)

    Bhojraj, Sanjay D; Al-Mallah, Mouaz H

    2009-01-01

    As the role of cardiovascular computed tomography angiography (CCTA) is further expanded through research, the use of this technology will expand as a result of demand both from medical professionals and the public. To ensure a standardized quality of interpretation of these scans in the face of an increased demand for physicians qualified to interpret these studies, the Society of Cardiovascular Computed Tomography, along with several other professional societies, has proposed a didactic curriculum for the study of CCTA. This review highlights the currently proposed didactic curriculum for the study of CCTA, examines current trends in training for both medical trainees and physicians in practice, and proposes future directions for the study of CCTA.

  1. Computer tomography investigation of epilepsy the brain atrophy

    International Nuclear Information System (INIS)

    The problem of brain atrophy in patients with epilepsy is often discussed in literature. The aim of the study is to present the results of computer tomography measurements of ventricular size and sulci of brain of 90 patients with various electro-clinical forms of epilepsy, including males and females at the age of 15 to 70 years. Computer tomography measurements were performed having in mind 6 parameters (frontal horn index, FHI; Huckman's number, HZ; cella media index,CMI; width of the third and the fourth ventricles; sulci). The results were compared to the CT measurements of a control group of 40 healthy males and females in the same age range.The obtained data indicate high percentage of subcortical atrophy among patients with epilepsy. Ventricular dilatation was found to be in light extent occurring most early in the frontal brain regions (frontal horns and lateral ventricles)., furthermore observed in the young age. (author)

  2. Analytic reconstruction approach for parallel translational computed tomography.

    Science.gov (United States)

    Kong, Huihua; Yu, Hengyong

    2015-01-01

    To develop low-cost and low-dose computed tomography (CT) scanners for developing countries, recently a parallel translational computed tomography (PTCT) is proposed, and the source and detector are translated oppositely with respect to the imaging object without a slip-ring. In this paper, we develop an analytic filtered-backprojection (FBP)-type reconstruction algorithm for two dimensional (2D) fan-beam PTCT and extend it to three dimensional (3D) cone-beam geometry in a Feldkamp-type framework. Particularly, a weighting function is constructed to deal with data redundancy for multiple translations PTCT to eliminate image artifacts. Extensive numerical simulations are performed to validate and evaluate the proposed analytic reconstruction algorithms, and the results confirm their correctness and merits. PMID:25882732

  3. Technical competence in cardiovascular magnetic resonance and computed tomography

    International Nuclear Information System (INIS)

    Cardiovascular magnetic resonance and computed tomography have evolved as very practical and useful techniques applied in clinical cardiology. Due to their rapid acceptance in the cardiology community and widespread use, training of both cardiologists and radiologists on this subspecialty has not been homogeneous so far. This in part explains significant differences observed in the diverse background found in today’s practicing physicians who execute these exams. In order to guide training facilities as well as both payers, contractors and general cardiologists ordering the exam, this document provides a minimum standard that should be accomplished by all physicians who pursue education in the field and for those who already practice in it. The clinical competences listed in this statement are by no means thorough but should be required by all those involved in cardiovascular magnetic resonance and computed tomography as the customary requirements for current and future practitioners. (author)

  4. Acute appendicitis: computed tomography findings - an iconographic essay

    International Nuclear Information System (INIS)

    Acute appendicitis is the most important cause of abdominal pain requiring surgical intervention in the Western world. The early diagnosis of this disease is of paramount relevance for minimizing its morbidity. Imaging methods have represented a huge progress in the diagnosis of this entity, which used to be based essentially on clinical history, physical examination and laboratory tests results, considering that 20% to 33% of patients present with atypical symptoms. Diagnostic difficulty is higher in children, the elderly, and women in childbearing age. The main imaging methods for evaluation of acute appendicitis are ultrasound and computed tomography. The present study is aimed at describing the disease physiopathology, commenting main computed tomography technical aspects, demonstrating and illustrating tomographic findings, and describing main differential diagnoses. (author)

  5. Intracranial Carotid Calcification on Cranial Computed Tomography

    Science.gov (United States)

    Subedi, Deepak; Zishan, Umme Sara; Chappell, Francesca; Gregoriades, Maria-Lena; Sudlow, Cathie; Sellar, Robin

    2015-01-01

    Background and Purpose— Intracranial internal carotid artery calcification is associated with cerebrovascular risk factors and stroke, but few quantification methods are available. We tested the reliability of visual scoring, semiautomated Agatston score, and calcium volume measurement in patients with recent stroke. Methods— We used scans from a prospective hospital stroke registry and included patients with anterior circulation ischemic stroke or transient ischemic stroke whose noncontrast cranial computed tomographic scans were available electronically. Two raters measured semiautomatic quantitative Agatston score, and calcium volume, and performed qualitative visual scoring using the original 4-point Woodcock score and a modified Woodcock score, where each image on which the internal carotid arteries appeared was scored and the slice scores summed. Results— Intra- and interobserver coefficient of variations were 8.8% and 16.5% for Agatston, 8.8% and 15.5% for calcium volume, and 5.7% and 5.4% for the modified Woodcock visual score, respectively. The modified Woodcock visual score correlated strongly with both Agatston and calcium volume quantitative measures (both R2=0.84; P<0.0001); calcium volume increased by 0.47-mm/point increase in modified Woodcock visual score. Intracranial internal carotid artery calcification increased with age by all measures (eg, visual score, Spearman ρ=0.4; P=0.005). Conclusions— Visual scores correlate highly with quantitative intracranial internal carotid artery calcification measures, with excellent observer agreements. Visual intracranial internal carotid artery scores could be a rapid and practical method for epidemiological studies. PMID:26251250

  6. Indications and Overuse of Computed Tomography in Minor Head Trauma

    OpenAIRE

    Zargar Balaye Jame, Sanaz; MAJDZADEH, Reza; AKBARI SARI, Ali; Rashidian, Arash; ARAB, Mohammad; Rahmani, Hojjat

    2014-01-01

    Background: Computed Tomography (CT) is a useful diagnostic technology, particularly in accident and emergency departments. Objectives: To identify a comprehensive list of indications for application of CT in patients with minor head trauma (MHT) and to determine appropriateness of its use on the basis of this list. Materials and Methods: A cross-sectional study was conducted in three Imaging centers in Tehran. A panel of experts developed a list of CT indications for MHT by reviewing documen...

  7. Computed tomography and the dilated pancreatic duct: An ominous sign

    Energy Technology Data Exchange (ETDEWEB)

    Palmer Gold, R.; Seaman, W.B.

    1981-01-15

    The main pancreatic duct has been visualized with both ultrasound and computed tomography. A normal pancreatic duct has been reported using CT, and controversy persists over whether a normal duct can be routinely imaged with ultrasound. The dilated pancreatic duct has always been associated with disease - usually pancreatitis or a proximal obstructing pancreatic carcinoma. In the patient with no clinical history or laboratory data suggesting pancreatitis, a dilated pancreatic duct implies a proximal tumor.

  8. Soil Macropore Structure Characterized by X-Ray Computed Tomography

    Institute of Scientific and Technical Information of China (English)

    FENG Jie; ZHANG Jia-Bao; ZHU An-Ning; BI Jing-Wei

    2003-01-01

    Undisturbed soil core with many macropores and disturbed soil core with only one macropore (diameter is 10 mm) were probed by x-ray computed tomography (CT). The size, number, shape and continuity of macropores in the transverse and vertical sections of soil were characterized using CT scanning images. The probability densities of macropores in the transverse section of soil core exhibited a logarithmic Γ distribution.Results indicated that CT scanning was a promising nondestructive method for characterizing macropores in soils.

  9. Internal mammary lymph node biopsy guided by computed tomography

    OpenAIRE

    Irving, Henry C; Hardy, Graham J.

    1982-01-01

    Internal mammary lymph node enlargement may be demonstrated using computed tomography (CT), and a confirmatory tissue diagnosis of metastatic involvement may be obtained using fine needle aspiration biopsy with needle tip placement guided by the CT scanner. A case history is described to illustrate how a patient presented 9 years after mastectomy with an internal mammary lymph node metastasis and how cytopathological diagnosis of this metastasis was achieved by CT guided biopsy.

  10. Experimentally determined spectral optimization for dedicated breast computed tomography

    OpenAIRE

    Prionas, Nicolas D.; Huang, Shih-Ying; Boone, John M.

    2011-01-01

    Purpose: The current study aimed to experimentally identify the optimal technique factors (x-ray tube potential and added filtration material∕thickness) to maximize soft-tissue contrast, microcalcification contrast, and iodine contrast enhancement using cadaveric breast specimens imaged with dedicated breast computed tomography (bCT). Secondarily, the study aimed to evaluate the accuracy of phantom materials as tissue surrogates and to characterize the change in accuracy with varying bCT tech...

  11. The possibilities of computer tomography in paecilomycosis of lungs

    OpenAIRE

    Abdusalom Ashurov; Rohila Jabbarova

    2010-01-01

    We have analyzed computed tomography (CT) results of chest in 56 patients with lung injures caused by paecilomycosis fungus at the age from 17 to 59 years. In our investigations, the perverted lung pattern due to pathology of interstitial tissue was observed in 52 (93%) patients of 56 (with chronic bronchitis - 100%, exogenous-allergic alveolitis - 93%, recurrent pneumonia - 100% and with bronchial asthma - 80%). Analysis showed that CT provides wide opportunities in visualization of all spec...

  12. Computed tomography in complex fractures of the ankle joint

    International Nuclear Information System (INIS)

    Diagnostic value of conventional roentgen technique and computed tomography is proofed by examination of 50 patients with sprain fractures of the ankle joint. The dimension of destruction of the distal tibial joint surface is better documented by CT than by other radiological techniques. Additional informations like multifragmentation of the distal tibia or evaluation of reposition impedigment are found more frequently by CT. Therefore indication and planning of the traumatherapy can be assessed better by the traumatologist. (orig.)

  13. The bipartite tarsal navicular bone: radiographic and computed tomography findings

    International Nuclear Information System (INIS)

    Two cases of bipartite tarsal navicular bone are presented. The radiographic and computed tomography (CT) findings of this anatomical variant are described. Correct recognition of this entity is important, both because it may be the cause of symptoms per se, and because it may be misdiagnosed as a fracture. When plain films are not diagnostic, CT scanning is helpful in distinguishing between a fracture and this variant. 6 refs., 4 figs

  14. Pulmonary Thromboembolic Disease: A New Role for Computed Tomography

    OpenAIRE

    Olsan, Adam D.; Matthews, Charles C.; Sullivan, Michael A.

    2002-01-01

    Over the past few years, computed tomography (CT) has emerged as a common noninvasive, definitive, alternative to ventilation-perfusion scintigraphy scan and pulmonary angiography in the evaluation of patients suspected of having pulmonary emboli. Additionally, recent articles have investigated the possibility of using CT to identify deep venous thrombi following a spiral CT pulmonary angiogram. Using the same bolus of contrast as that administered for a CT pulmonary angiogram, the ultimate g...

  15. Ureterolithiasis: classical and atypical findings on unenhanced helical computed tomography.

    Science.gov (United States)

    Vaswani, Kuldeep K; El-Dieb, Adam; Vitellas, Kenneth M; Bennett, William F; Bova, James G

    2002-03-01

    Evaluation of patients with acute flank pain using helical computed tomography (CT) is a well-accepted, rapid, and safe procedure in the emergency setting. Various primary and secondary signs are described in the literature for evaluation of these patients. Our purpose is to demonstrate both the classical findings associated with ureteral calculi on unenhanced helical CT and atypical findings and potential pitfalls. We also provide readers with a systematic approach to interpreting unenhanced helical CT scans performed for acute flank pain.

  16. The role of computed tomography in modern paediatric uroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Maudgil, D.D.; McHugh, K. E-mail: kmchugh@gosh.nhs.uk

    2002-08-01

    Computed tomography (CT) has developed a well-recognised role within paediatric uroradiology, especially in imaging of trauma, malignancy (in particular Wilms' tumour), atypical infection, and congenital urogenital abnormalities. CT can also be used for problem solving in nephrolithiasis and renal transplant assessment. These applications are illustrated and discussed, with an emphasis on particular information that can be gained from the CT study.

  17. Application of neutron computed tomography in the geosciences

    OpenAIRE

    Wilding, M; Shields, K.; Lesher, C. E.

    2005-01-01

    A research program that applies neutron computed tomography (CT) to geological problems has been developed at the McClellan Nuclear Radiation Center (UCD-MNRC) owned and operated by the University of California, Davis (UCD-MNRC). The high penetration of neutrons, their sensitivity to light elements, and their special sensitivity to hydrogen (in water or organic materials) make them an ideal tool for non-destructive examination of complex materials of geological interest. There are four resear...

  18. Fast neutron computed tomography with TV imaging at YAYOI

    International Nuclear Information System (INIS)

    A highly sensitive scintillation converter was used for the fast neutron television (FNTV) method. We examined the fast neutron computed tomography (FNCT) using the television (TV) method and evaluated the total CT imaging system by the modulation transfer function (MTF). The MTF evaluation showed the spatial resolution to be 1.4 mm. This was two or three times larger than the pixel size. The spatial resolution was restricted by pixel size in the present FNTV-CT system. (orig.)

  19. Establishing normal reference values in quantitative computed tomography of emphysema

    OpenAIRE

    Smith, Benjamin M.; Barr, R Graham

    2013-01-01

    Quantitative computed tomography (QCT) can provide reliable and valid measures of lung structure and volumes. Similar to lung function and volumes measured by spirometry, lung measures obtained by QCT vary by demographic and anthropomorphic factors including sex, race/ethnicity and height in asymptomatic non-smokers. Hence, some accounting for these factors is necessary to define abnormal from normal QCT values and disease severity. Similar to spirometry and cardiac volumes, prediction equati...

  20. Use of dentomaxillofacial cone beam computed tomography in dentistry

    OpenAIRE

    KAMBUROĞLU, Kıvanç

    2015-01-01

    Cone-beam computed tomography (CBCT) was developed and introduced specifically for dento-maxillofacial imaging. CBCT possesses a number of advantages over medical CT in clinical practice, such as lower effective radiation doses, lower costs, fewer space requirements, easier image acquisition, and interactive display modes such as mutiplanar reconstruction that are applicable to maxillofacial imaging. However, the disadvantages of CBCT include higher doses than two-dimensional imaging; the ina...

  1. Quantitative computed tomography imaging of airway remodeling in severe asthma

    OpenAIRE

    Grenier, Philippe A.; Fetita, Catalin I.; Brillet, Pierre-Yves

    2016-01-01

    Asthma is a heterogeneous condition and approximately 5–10% of asthmatic subjects have severe disease associated with structure changes of the airways (airway remodeling) that may develop over time or shortly after onset of disease. Quantitative computed tomography (QCT) imaging of the tracheobronchial tree and lung parenchyma has improved during the last 10 years, and has enabled investigators to study the large airway architecture in detail and assess indirectly the small airway structure. ...

  2. An Evaluation of a Prototype Proton Computed Tomography Scanner

    OpenAIRE

    Plautz, Tia Elizabeth

    2016-01-01

    Since the 1990s, the number of clinical proton therapy facilities around the world has been growing exponentially. Because of this, and the lack of imaging support for proton therapy in the treatment room, a renewed interest in proton radiography and computed tomography (CT) has emerged. This imaging modality was largely abandoned in the 1970s and '80s in favor of the already successful x-ray CT, for reasons including long acquisition times and inadequate spatial resolution. Protons are parti...

  3. Computed tomography in patients with Ehlers-Danlos syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Hagino, Hiroshi; Sugitani, Akitoshi; Eda, Isematsu; Takashima, Sachio; Takeshita, Kenzo

    1985-09-01

    Three patients with Ehlers-Danlos syndrome were reported. Unusual findings on computed tomography were seen in two of the three patients. One case showed peculiar and marked dilatation of the 4th ventricle, supracerebellar cistern and lateral ventricle. The other case presented disproportionate enlargement of the anterior horn of the lateral ventricle. These CT findings in the two patients suggest that developmental abnormalities may constitute a structural defect.

  4. Use of Cone Beam Computed Tomography in Endodontics

    Directory of Open Access Journals (Sweden)

    William C. Scarfe

    2009-01-01

    Full Text Available Cone Beam Computed Tomography (CBCT is a diagnostic imaging modality that provides high-quality, accurate three-dimensional (3D representations of the osseous elements of the maxillofacial skeleton. CBCT systems are available that provide small field of view images at low dose with sufficient spatial resolution for applications in endodontic diagnosis, treatment guidance, and posttreatment evaluation. This article provides a literature review and pictorial demonstration of CBCT as an imaging adjunct for endodontics.

  5. Role of computed tomography in the study of vascular pathology

    Energy Technology Data Exchange (ETDEWEB)

    Procacci, C.; Bicego, E.; Bergamo, I.A. and others

    1988-01-01

    The most important indications to the use of computed tomography (CT) in the study of vascular pathology are considered. They may be divided as follows: 1) demonstration of vascular involvement by thoraco-abdominal neoplasms; 2) differential diagnosis between primary vascular and extra-vascular pathology; 3) assessment of primary arterial pathology. For each group, those pathologies are considered, for which CT plays a fundamental role.

  6. Abdominal Computed Tomography Findings of Malaria Infection with Plasmodium vivax

    OpenAIRE

    Kim, Eun Mi; Cho, Hyeon Je; Cho, Chong Rae; Kwak, Yee Gyung; Kim, Mi Young; Cho, Yun Ku

    2010-01-01

    Abdominal computed tomography (CT) findings of malaria are not well-known even though malaria is a serious infectious disease. To identify abdominal CT findings, we selected 34 of 405 patients who had a positive peripheral blood smear for Plasmodium vivax and had underwent abdominal CT as the malaria group. We also selected 80 patients who had fever and a negative peripheral blood smear as the control group and 120 healthy people as the normal group. We reviewed and analyzed their medical rec...

  7. Computed tomography changes following cryotherapy for hepatic cancer

    International Nuclear Information System (INIS)

    Encouraging survival and tumour marker results have been described in patients where the focally destructive technique, hepatic cryotherapy, is used to treat primary and secondary hepatic malignancy. Radiology allows assessment of the cryotherapy procedure and follow-up treatment. This paper aims to review and describe the appearance of hepatic cryotherapy by computed tomography which allows assessment of the adequacy of surgical technique and offers the ability to identify recurrences that may be suitable for further treatment

  8. Computed tomography changes following cryotherapy for hepatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    King, J.; Morris, D. L. [University of NSW, Sydney (Australia). Department of Surgery; Glenn, D. [St George Hospital, Kogarah, Sydney (Australia). Department of Radiology

    1997-05-01

    Encouraging survival and tumour marker results have been described in patients where the focally destructive technique, hepatic cryotherapy, is used to treat primary and secondary hepatic malignancy. Radiology allows assessment of the cryotherapy procedure and follow-up treatment. This paper aims to review and describe the appearance of hepatic cryotherapy by computed tomography which allows assessment of the adequacy of surgical technique and offers the ability to identify recurrences that may be suitable for further treatment. 11 refs., 1 tab., 9 figs.

  9. Use of Cone Beam Computed Tomography in Endodontics

    OpenAIRE

    Scarfe, William C.; Levin, Martin D.; David Gane; Allan G. Farman

    2009-01-01

    Cone Beam Computed Tomography (CBCT) is a diagnostic imaging modality that provides high-quality, accurate three-dimensional (3D) representations of the osseous elements of the maxillofacial skeleton. CBCT systems are available that provide small field of view images at low dose with sufficient spatial resolution for applications in endodontic diagnosis, treatment guidance, and posttreatment evaluation. This article provides a literature review and pictorial demonstration of CBCT as an imagin...

  10. Multidetector computed tomography of the coronary arteries - pictorial essay

    International Nuclear Information System (INIS)

    Multidetector computed tomography (MDCT) is being used more frequently for the detection of atherosclerotic coronary artery disease (CAD). MDCT allows for very rapid image acquisition with little motion artifact, resulting in the ability to quantitate calcified atherosclerotic plaque. Congenital coronary artery anomalies are readily identified using this technique. A key advantage is the noninvasiveness of the study, with no intravascular contrast media needed. Knowledge of coronary artery anatomy as well as of the potential pitfalls is required. (author)

  11. Computed Tomography Inspection and Analysis for Additive Manufacturing Components

    Science.gov (United States)

    Beshears, Ronald D.

    2016-01-01

    Computed tomography (CT) inspection was performed on test articles additively manufactured from metallic materials. Metallic AM and machined wrought alloy test articles with programmed flaws were inspected using a 2MeV linear accelerator based CT system. Performance of CT inspection on identically configured wrought and AM components and programmed flaws was assessed using standard image analysis techniques to determine the impact of additive manufacturing on inspectability of objects with complex geometries.

  12. Thermal Neutron Computed Tomography of Soil Water and Plant Roots

    OpenAIRE

    Leanne G. Tumlinson; Hungyuan Liu; Wendy K. Silk; Hopmans, Jan W.

    2007-01-01

    Neutron radiography is a noninvasive imaging technique that measures the attenuation of thermal neutrons, as is done with x-ray and γ-ray radiography, to characterize the internal composition of materials. Neutron and x-ray imaging are complementary techniques, with neutron imaging especially well suited for materials containing H atoms and other low-atomic-weight attenuating materials. Although neutron computed tomography (NCT) techniques are routinely used in engineering, relatively little ...

  13. Computed tomography in complex fractures of the ankle joint

    Energy Technology Data Exchange (ETDEWEB)

    Friedburg, H.; Wimmer, B.; Hendrich, V.; Riede, U.N.

    1983-09-01

    Diagnostic value of conventional roentgen technique and computed tomography is proofed by examination of 50 patients with sprain fractures of the ankle joint. The dimension of destruction of the distal tibial joint surface is better documented by CT than by other radiological techniques. Additional informations like multiframentation of the distal tibia or evaluation of reposition impediment are found more frequently by CT. Therefore indication and planning of the traumatherapy can be assessed better by the traumatologist.

  14. [Multislice spiral computed tomography in the diagnosis of osteomyelitis].

    Science.gov (United States)

    Egorova, E A; Zorina, I S; Sangaeva, L M

    2010-01-01

    This paper deals with the results of a radiation study in 34 patients with the clinical manifestations of maxillofacial osteomyelitides. It describes the radiation semiotics of changes occurring in the bone and its surrounding soft tissues of the maxillofacial region in different phases of osteomyelitis. Comparative analysis of orthopantograms and images obtained by multislice spiral computed tomography revealed the benefits of the latter in detecting soft tissue changes and subtle bone alterations.

  15. Use of Positron Emission Tomography/Computed Tomography in Radiation Treatment Planning for Lung Cancer

    OpenAIRE

    Kezban Berberoğlu

    2016-01-01

    Radiotherapy (RT) plays an important role in the treatment of lung cancer. Accurate diagnosis and staging are crucial in the delivery of RT with curative intent. Target miss can be prevented by accurate determination of tumor contours during RT planning. Currently, tumor contours are determined manually by computed tomography (CT) during RT planning. This method leads to differences in delineation of tumor volume between users. Given the change in RT tools and methods due to rapidly ...

  16. SADMFR Guidelines for the Use of Cone-Beam Computed Tomography/Digital Volume Tomography

    OpenAIRE

    Dula, Karl; Benic, Goran I; Bornstein, Michael; Dagassan-Berndt, Dorothea; Filippi, Andreas; Hicklin, Stefan; Kissling-Jeger, Franziska; Luebbers, Heinz-Theo; Sculean, Anton; Sequeira-Byron, Patrick; Walter, Clemens; Zehnder, Matthias

    2015-01-01

    In 2011, the first consensus conference on guidelines for the use of cone-beam computed tomography (CBCT) was convened by the Swiss Society of Dentomaxillofacial Radiology (SGDMFR). This conference covered topics of oral and maxillofacial surgery, temporomandibular joint dysfunctions and disorders, and orthodontics. In 2014, a second consensus conference was convened on guidelines for the use of CBCT in endodontics, periodontology, reconstructive dentistry and pediatric dentistry. The guideli...

  17. Helical computed tomography in the assessment of abdominal aortic pathology

    Energy Technology Data Exchange (ETDEWEB)

    Vicaretti, M.; Young, N.; Jenkins, J.; Fletcher, J. [Westmead Hospital, Westmead, NSW (Australia)

    1997-05-01

    A pilot study was undertaken to evaluate the role of helical computed tomography in the assessment of abdominal aortic pathology. A total of 17 patients underwent intra-arterial digital subtraction angiography (IADSA) and helical computed tomography, with eight patients undergoing subsequent operative intervention. A comparison of radiological findings between IADSA and helical computed tomography (CT) was made and, where applicable, a comparison was made with operative findings. Pathology included abdominal aortic aneurysm (AAA) (n=12), thoraco abdominal aneurysm (n=2) and dissection (n=1), graft distension following AAA repair (n=1) and plaque haemorrhage in the distal aorta following percutaneous transluminal angioplasty (PTA) of the iliac artery (n=1). Planned operative management as based on pre-operative helical CT imaging findings, in particular with reference to the type of graft used (straight or bifurcated) was not changed at operation. Our findings on helical CT in regards to AAA, thoraco-abdominal aneurysm and dissection correlated well with angiography and surgery findings. (authors). 26 refs., 2 tabs., 5 figs.

  18. Efficacy of multislice computed tomography for gastroenteric and hepatic surgeries

    Institute of Scientific and Technical Information of China (English)

    Hiroshi Ohtani; Mitsuo Tsubakimoto; Hidemi Kawajiri; Yuichi Arimoto; Koichi Ohno; Yasuhisa Fujimoto; Hiroko Oba; Kenji Adachi; Masaya Hirano; Shoichi Terakawa

    2005-01-01

    AIM: To determine the efficacy of multislice CT for gastroenteric and hepatic surgery.METHODS: Dual-phase helical computed tomography was performed in 50 of 51 patients who underwent gastroenteric and hepatic surgeries. Twenty-eight, eighteen and four patients suffering from colorectal cancer, gastric cancer,and liver cancer respectively underwent colorectal surgery (laparoscopic surgery: 6 cases), gastrectomy, and hepatectomy. Three-dimensional computed tomography imaging of the inferior mesenteric artery, celiac artery and hepatic artery was performed. And in the follow-up examination of postoperative patients, multiplanar reconstruction image was made in case of need.RESULTS: Scans in 50 patients were technically satisfactory and included in the analysis. Depiction of major visceral arteries, which were important for surgery and other treatments, could be done in all patients.Preoperative visualization of the left colic artery and sigmoidal arteries, the celiac artery and its branches, and hepatic artery was very useful to lymph node dissection,the planning of a reservoir and hepatectomy. And multiplanar reconstruction image was helpful to diagnosis for the postoperative follow-up of patients.CONCLUSION: Three-dimensional volume rendering or multiplanar reconstruction imaging performed by multislice computed tomography was very useful for gastroenteric and hepatic surgeries.

  19. Anatomical structure of lingual foramen in cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ki, Min Woo; Hwang, Eui Hwan; Lee, Sang Rae [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    2004-07-15

    To evaluate whether cone beam computed tomography can depict the distribution, position, frequency, relative vertical dimension, and the diameter of the lingual foramen and direction of lingual bone canal. Cone beam computed tomography of mandible was performed on 25 males and 25 females with no history of any orthodontic treatments or any other dental surgeries. A statistical comparison was done on the mean values of males and females. In the location and distribution of lingual foramina, median lingual foramen was found in all subjects and lateral lingual foramen in 58%. In the lateral lingual foramen, bilateral type was found in 28% and unilateral type in 30%. In the number of lingual foramina, median lingual foramen had two foramina and lateral lingual foramen had one foramen, mostly. In the relative mean vertical dimension of lingual foramina, median lingual foramen was 0.03 {+-} 0.08, and both lateral lingual foramina was 0.20 {+-} 0.04. The mean diameter of lingual foramina, median lingual foramen was 0.9 mm {+-} 0.28, right lateral lingual foramen was 0.92 mm {+-} 0.23, and left lateral lingual foramen was 0.88 mm {+-} 0.27. The most frequent direction of the lingual bone canals, median lingual bone canal proceeded in anteroinferior direction and lateral lingual bone canal in anterosuperolateral direction. Cone beam computed tomography can be helpful for surgery and implantation on the mandibular area. Radiologist should be aware of this anatomical feature and its possible implications.

  20. Multidetector computed tomography in the preoperative staging of gastric adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Ricardo Hoelz de Oliveira; Penachim, Thiago Jose; Martins, Daniel Lahan; Andreollo, Nelson Adami; Caserta, Nelson Marcio Gomes, E-mail: rhobarros@hotmail.com [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil)

    2015-03-15

    Objective: To evaluate the role of multidetector computed tomography in the preoperative investigation of tumor invasion depth and lymph node and metastatic involvement according to the TNM classification, in patients with gastric adenocarcinoma. Materials and Methods: Fifty-four patients with biopsy-confirmed gastric cancer underwent preoperative staging with 64-channel multidetector computed tomography. Two independent radiologists analyzed the images and classified the findings. Sensitivity, specificity, accuracy and overall accuracy were calculated for each observer. The interobserver agreement was also evaluated. Results: The accuracy in the classification of categories T ranged from 74% to 96% for observer 1 and from 80% to 92% for observer 2. The overall accuracy was 70% for both observers. The weighted kappa index was 0.75, consistent with a significant interobserver agreement. The accuracy in the classification of lymph node involvement (category N) ranged from 55% to 79% for observer 1 and from 73% to 82% for observer 2. The evaluation of metastatic involvement showed an overall accuracy of 89.6% for both observers. Conclusion: 64-channel multidetector computed tomography demonstrated clinically relevant accuracy in the preoperative staging of gastric adenocarcinoma as regards invasion depth (T category) and metastatic involvement (M category). (author)

  1. Correlation of echoencephalography and computer tomography in expansive brain lesions

    International Nuclear Information System (INIS)

    50 patients with confirmed expansive intracranial processes were examined by two methods - echoencephalography and computer tomography. The deviation of the middle echo from two points on the calva and the corresponding deviation of septum pellucidum and epiphysis according to the computer tomography examination were compared. The findings are not quite identical. As a rule there is a minor deviation in echoencephalography examinations as compared with the deviation of corresponding structures according to computer tomography, the difference, however, does not exceed 3 mm. Echoencephalography examinations made at two different points on the calva increase the accuracy and sensitivity of the finding. In expansive processes with a more lateral and posterior localization we usually do not only find greater shifts of the echoencephalography in the anterior as well as posterior temporal region but also an increased difference between the two deviations. Despite the use of most up-to-date diagnostic methods echoencephalography remains a rapid, low-cost and unpretentious method in neurology and neurosurgery. It provides, however, only information for orientation and is biassed with an 5 to 8% error. (author)

  2. Dosimetry in abdominal imaging by 6-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Sonia Isabel [Hospital de Faro, EPE (Portugal); Abrantes, Antonio Fernando; Ribeiro, Luis Pedro; Almeida, Rui Pedro Pereira [University of Algarve (Portugal). School of Health. Dept. of Radiology

    2012-11-15

    Objective: To determine the effective dose in abdominal computed tomography imaging and to study the influence of patients' characteristics on the received dose. Materials and Methods: Dose values measurements were performed with an ionization chamber on phantoms to check the agreement between dose values and those presented by the computed tomography apparatus, besides their compliance with the recommended reference dose levels. Later, values of dose received by physically able patients submitted to abdominal computed tomography (n = 100) were measured and correlated with their anthropometric characteristics. Finally, the dose to organs was simulated with the Monte Carlo method using the CT-Expo V 1.5 software, and the effect of automatic exposure control on such examinations. Results: The main characteristics directly influencing the dose include the patients' body mass, abdominal perimeter and body mass index, whose correlation is linear and positive. Conclusion: The radiation dose received from abdominal CT scans depends on some patient's characteristics, and it is important to adjust the acquisition parameters to their dimensions (author)

  3. Hepatic hemangiomas as diagnosed by ultrasonography and computed tomography

    International Nuclear Information System (INIS)

    A total of 62 cases where the clinical diagnosis of hepatic hemangioma had been established during the period between 1981 and 1983 on the basis of computed tomography and sonography were subjected to retrospective analysis with the aim of evaluating the diagnostic reliability of these two methods. In 29 patients a typical distribution pattern of the contrast medium gave irrefutable evidence of the disease. Hemangiomas were predicted from the results of computed tomography for a further 5 patients with less revealing distribution patterns, although in 4 among these the preliminary diagnosis of hemangioma was disproved by additional diagnostic procedures (scintigraphy, laparoscopy, surgery and biopsy). Out of 16 patients, in which the hemangiomas were diagnosed from the typical patterns created by the contrast medium on the CT scans, 11 showed sonographic findings to confirm the presence of such tumours. This retrospective analysis showed that a correct and positive diagnosis could be established in no more than 7 patients on the basis of sonography alone, while 6 such diagnoses were definitely proven to be false-positive. As regards diagnostic accuracy, sonography clearly compares unfavourably with computed tomography. It may offer some advantages inasmuch as it requires no radiation exposure, is non-invasive and, last not least, less costly. (ECB)

  4. Clinical utility of dental cone-beam computed tomography: current perspectives

    Directory of Open Access Journals (Sweden)

    Jaju PP

    2014-04-01

    Full Text Available Prashant P Jaju,1 Sushma P Jaju21Oral Medicine and Radiology, 2Conservative Dentistry and Endodontics, Rishiraj College of Dental Sciences and Research Center, Bhopal, IndiaAbstract: Panoramic radiography and computed tomography were the pillars of maxillofacial diagnosis. With the advent of cone-beam computed tomography, dental practice has seen a paradigm shift. This review article highlights the potential applications of cone-beam computed tomography in the fields of dental implantology and forensic dentistry, and its limitations in maxillofacial diagnosis.Keywords: dental implants, cone-beam computed tomography, panoramic radiography, computed tomography

  5. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    Energy Technology Data Exchange (ETDEWEB)

    Hochhegger, Bruno, E-mail: brunohochhegger@googlemail.co [Hospital Moinhos de Vento, Porto Alegre, RS (Brazil); Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia; Irion, Klaus L. [Liverpool Heart and Chest Hospital, Liverpool (United Kingdom); Oliveira, Hugo [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil)

    2010-07-15

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  6. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    International Nuclear Information System (INIS)

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  7. Multi-scale analysis of lung computed tomography images

    CERN Document Server

    Gori, I; Fantacci, M E; Martinez, A Preite; Retico, A; De Mitri, I; Donadio, S; Fulcheri, C; Gargano, G; Magro, R; Santoro, M; Stumbo, S; 10.1088/1748-0221/2/09/P09007

    2009-01-01

    A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on a dataset of low-dose and thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.

  8. Multi-scale analysis of lung computed tomography images

    CERN Document Server

    Gori, I; Fantacci, M E; Preite Martinez, A; Retico, A; De Mitri, I; Donadio, S; Fulcheri, C

    2007-01-01

    A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on a dataset of low-dose and thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.

  9. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y;

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...... myocardial infarction, the AUC was 0.90 (95% CI: 0.87-0.94) and in patients without prior CAD the AUC for combined CTA-CTP was 0.93 (95% CI: 0.89-0.97). For the combination of a CTA stenosis ≥50% stenosis and a CTP perfusion deficit, the sensitivity, specificity, positive predictive, and negative predicative...

  10. Nonoperative treatment of splenic trauma: usefulness of computed tomography

    International Nuclear Information System (INIS)

    Objective: to report the results of use of conservative treatment in patients with splenic trauma and to emphasize the usefulness of computed tomography in these cases. Material and method: sixty-nine cases of pediatric patients with blunt abdominal trauma seen from from January 2001 to June 2004 at the level I trauma center were retrospectively studied. Forty-four of these patients were submitted to nonoperative treatment and the clinical follow-up was performed by computerized tomography. All patients had been diagnosed with splenic injury by computerized tomography.Results: the causes of the injuries were motor vehicle accident in 12 (27.2%) patients, bicycle accident in nine (20.4%) patients, and falls in 23 (52.2%) patients. Two (3.7%) patients died from associated injuries. The mean duration of hospital stay was six days. The mean age of the patients was nine years. Conclusion: conservative treatment for blunt splenic trauma is performed with the aim of reducing costs and risks for the patients, and computerized tomography should be routinely used. No posterior complications were observed in this approach. (author)

  11. Observation of the pulp horn by swept source optical coherence tomography and cone beam computed tomography

    Science.gov (United States)

    Iino, Yoshiko; Yoshioka, Toshihiko; Hanada, Takahiro; Ebihara, Arata; Sunakawa, Mitsuhiro; Sumi, Yasunori; Suda, Hideaki

    2015-02-01

    Cone-beam computed tomography (CBCT) is one of the most useful diagnostic techniques in dentistry but it involves ionizing radiation, while swept source optical coherence tomography (SS-OCT) has been introduced recently as a nondestructive, real-time, high resolution imaging technique using low-coherence interferometry, which involves no ionizing radiation. The purpose of this study was to evaluate the ability of SS-OCT to detect the pulp horn (PH) in comparison with that of CBCT. Ten extracted human mandibular molars were used. After horizontally removing a half of the tooth crown, the distance from the cut dentin surface to PH was measured using microfocus computed tomography (Micro CT) (SL) as the gold standard, by CBCT (CL) and by SS-OCT (OL). In the SS-OCT images, only when PH was observed beneath the overlying dentin, the distance from the cut dentin surface to PH was recorded. If the pulp was exposed, it was defined as pulp exposure (PE). The results obtained by the above three methods were statistically analyzed by Spearman's rank correlation coefficient at a significance level of p images correlated closely with CBCT images, suggesting that SS-OCT can be a useful tool for the detection of PH.

  12. Computed tomography and (18)F-fluorodeoxyglucose positron emission tomography/computed tomography findings in adrenal candidiasis and histoplasmosis: two cases.

    Science.gov (United States)

    Altinmakas, Emre; Guo, Ming; Kundu, Uma R; Habra, Mouhammed Amir; Ng, Chaan

    2015-01-01

    We report the contrast-enhanced computed tomography (CT) and (18)F-fluorodeoxyglucose positron emission tomography findings in adrenal histoplasmosis and candidiasis. Both demonstrated bilateral hypermetabolic heterogeneous adrenal masses with limited wash-out on delayed CT. Adrenal candidiasis has not been previously reported, nor have the CT wash-out findings in either infection. The adrenal imaging findings are indistinguishable from malignancy, which is more common; but in this setting, physicians should be alert to the differential diagnosis of fungal infections, since it can be equally deadly.

  13. Paracoccidioidomycosis: High-resolution computed tomography-pathologic correlation

    International Nuclear Information System (INIS)

    Objective: The purpose of this study was to describe the high-resolution computed tomography (HRCT) features of pulmonary paracoccidioidomycosis and to correlate them with pathologic findings. Methods: The study included 23 adult patients with pulmonary paracoccidioidomycosis. All patients had undergone HRCT, and the images were retrospectively analyzed by two chest radiologists, who reached decisions by consensus. An experienced lung pathologist reviewed all pathological specimens. The HRCT findings were correlated with histopathologic data. Results: The predominant HRCT findings included areas of ground-glass opacities, nodules, interlobular septal thickening, airspace consolidation, cavitation, and fibrosis. The main pathological features consisted of alveolar and interlobular septal inflammatory infiltration, granulomas, alveolar exudate, cavitation secondary to necrosis, and fibrosis. Conclusion: Paracoccidioidomycosis can present different tomography patterns, which can involve both the interstitium and the airspace. These abnormalities can be pathologically correlated with inflammatory infiltration, granulomatous reaction, and fibrosis.

  14. Paracoccidioidomycosis: High-resolution computed tomography-pathologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson, E-mail: edmarchiori@gmail.com [Fluminense Federal University, Rio de Janeiro (Brazil); Federal University of Rio de Janeiro, Rio de Janeiro (Brazil); Valiante, Paulo Marcos, E-mail: valiante.rlk@terra.com.br [Federal University of Rio de Janeiro, Rio de Janeiro (Brazil); Mano, Claudia Mauro, E-mail: cacaumano@gmail.com [Fluminense Federal University, Rio de Janeiro (Brazil); Zanetti, Glaucia, E-mail: glauciazanetti@gmail.com [Federal University of Rio de Janeiro, Rio de Janeiro (Brazil); Petropolis Faculty of Medicine, Rio de Janeiro (Brazil); Escuissato, Dante L., E-mail: danteescuissato@gmail.com [Federal University of Parana, Curitiba (Brazil); Souza, Arthur Soares, E-mail: asouzajr@gmail.com [Faculty of Medicine of Rio Preto, Sao Paulo (Brazil); Capone, Domenico, E-mail: domenicocap@gmail.com [Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)

    2011-01-15

    Objective: The purpose of this study was to describe the high-resolution computed tomography (HRCT) features of pulmonary paracoccidioidomycosis and to correlate them with pathologic findings. Methods: The study included 23 adult patients with pulmonary paracoccidioidomycosis. All patients had undergone HRCT, and the images were retrospectively analyzed by two chest radiologists, who reached decisions by consensus. An experienced lung pathologist reviewed all pathological specimens. The HRCT findings were correlated with histopathologic data. Results: The predominant HRCT findings included areas of ground-glass opacities, nodules, interlobular septal thickening, airspace consolidation, cavitation, and fibrosis. The main pathological features consisted of alveolar and interlobular septal inflammatory infiltration, granulomas, alveolar exudate, cavitation secondary to necrosis, and fibrosis. Conclusion: Paracoccidioidomycosis can present different tomography patterns, which can involve both the interstitium and the airspace. These abnormalities can be pathologically correlated with inflammatory infiltration, granulomatous reaction, and fibrosis.

  15. Computed Tomography Imaging of the Topographical Anatomy of Canine Prostate

    International Nuclear Information System (INIS)

    AIM: To investigate the topographical anatomy of canine prostate gland by computed tomography (CT) for diagnostic imaging purposes. ÐœATERIAL AND METHODS: Seven clinically healthy mongrel male dogs at the age of 3−4 years and body weight of 10−15 kg were submitted to transverse computerized axial tomography (CAT) with cross section thickness of 5 mm. RESULTS: The CT image of canine prostate is visualized throughout the scans of the pelvis in the planes through the first sacral vertebra (S1) dorsally; the bodies of iliac bones laterally and cranially to the pelvic brim (ventrally). The body of prostate appears as an oval homogenous relatively hypo dense finding with soft tissue density. The gland is well differentiated from the adjacent soft tissues. CONCLUSION: By means of CT, the cranial part of prostate gland in adult dogs aged 3−4 years exhibited an abdominal localization. (author)

  16. A review of X-ray computed axial tomography

    International Nuclear Information System (INIS)

    A review of Computed axial tomography (CAT) scanning literature outlining the theoretical and practical aspects of this technique with application in both medical diagnosis and industrial non-destructive inspection (NDI) is presented. Practical aspects of CAT scanning discussed include : radiation sources, currently available spatial and contrast resolution limits and the evolution of the computerized tomography (CT) system. It was found that monochromatic gamma rays are preferred to X-rays, especially for very high density materials, and that in medical CAT scanning, the special resolution is only, 0.5 mm while spatial resolutions of less than 50μm have been achieved in NDI. An increased number of scientific and industrial applications are anticipated (e.g. for studying sintering reactions), as the capital cost of CAT scanning decreased. 13 refs., 9 figs., 2 tabs

  17. Combined positron emission tomography and computed tomography to visualize and quantify fluid flow in sedimentary rocks

    Science.gov (United States)

    Fernø, M. A.; Gauteplass, J.; Hauge, L. P.; Abell, G. E.; Adamsen, T. C. H.; Graue, A.

    2015-09-01

    Here we show for the first time the combined positron emission tomography (PET) and computed tomography (CT) imaging of flow processes within porous rocks to quantify the development in local fluid saturations. The coupling between local rock structure and displacement fronts is demonstrated in exploratory experiments using this novel approach. We also compare quantification of 3-D temporal and spatial water saturations in two similar CO2 storage tests in sandstone imaged separately with PET and CT. The applicability of each visualization technique is evaluated for a range of displacement processes, and the favorable implementation of combining PET/CT for laboratory core analysis is discussed. We learn that the signal-to-noise ratio (SNR) is over an order of magnitude higher for PET compared with CT for the studied processes.

  18. Reconstruction Algorithms for Positron Emission Tomography and Single Photon Emission Computed Tomography and their Numerical Implementation

    CERN Document Server

    Fokas, A S; Marinakis, V

    2004-01-01

    The modern imaging techniques of Positron Emission Tomography and of Single Photon Emission Computed Tomography are not only two of the most important tools for studying the functional characteristics of the brain, but they now also play a vital role in several areas of clinical medicine, including neurology, oncology and cardiology. The basic mathematical problems associated with these techniques are the construction of the inverse of the Radon transform and of the inverse of the so called attenuated Radon transform respectively. We first show that, by employing mathematical techniques developed in the theory of nonlinear integrable equations, it is possible to obtain analytic formulas for these two inverse transforms. We then present algorithms for the numerical implementation of these analytic formulas, based on approximating the given data in terms of cubic splines. Several numerical tests are presented which suggest that our algorithms are capable of producing accurate reconstruction for realistic phanto...

  19. Unusual case of infantile fibrosarcoma evaluated on F-18 fluorodeoxyglucose positron emission tomography-computed tomography.

    Science.gov (United States)

    Bedmutha, Akshay; Singh, Natasha; Shivdasani, Divya; Gupta, Nitin

    2016-01-01

    Infantile fibrosarcoma (IFS) is a rare soft-tissue sarcoma originating from extremities and occasionally from axial soft tissue. The prognosis is good with favorable long-term survival. It is rarely metastasizing tumor, the chances being lesser with IFS originating from extremities. Use of neoadjuvant chemotherapy (NACT) as a treatment regime further reduces the chances of local relapse and distant metastasis. The organs commonly affected in metastatic IFS are lungs and lymph nodes. We report an unusual case of an IFS originating from extremity, which received NACT, yet presented with an early metastatic disease involving soft tissues and sparing lungs and lymph nodes, as demonstrated on fluorodeoxyglucose positron emission tomography-computed tomography. PMID:27385891

  20. Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Dongmei; Zhu, Shouping, E-mail: zhusp2009@gmail.com; Chen, Xueli; Chao, Tiantian; Cao, Xu; Zhao, Fengjun; Huang, Liyu; Liang, Jimin [Engineering Research Center of Molecular and Neuro Imaging of Ministry of Education and School of Life Science and Technology, Xidian University, Xi' an, Shaanxi 710071 (China)

    2014-11-10

    X-ray luminescence tomography (XLT) is an imaging technology based on X-ray-excitable materials. The main purpose of this paper is to obtain quantitative luminescence concentration using the structural information of the X-ray computed tomography (XCT) in the hybrid cone beam XLT/XCT system. A multi-wavelength luminescence cone beam XLT method with the structural a priori information is presented to relieve the severe ill-posedness problem in the cone beam XLT. The nanophosphors and phantom experiments were undertaken to access the linear relationship of the system response. Then, an in vivo mouse experiment was conducted. The in vivo experimental results show that the recovered concentration error as low as 6.67% with the location error of 0.85 mm can be achieved. The results demonstrate that the proposed method can accurately recover the nanophosphor inclusion and realize the quantitative imaging.

  1. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Erdem Sürücü

    2016-10-01

    Full Text Available A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT.

  2. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of primary pulmonary angiosarcomas

    International Nuclear Information System (INIS)

    Angiosarcoma is a malignant vascular tumor that originates from the mesenchymal cells which have undergone angioblastic differentiation. Pulmonary angiosarcomas are invariably (>90%) metastatic tumors form primaries of the skin, bone, liver, breast, or heart. Primary pulmonary angiosarcomas are exceedingly rare, with just about 20 cases being reported in the literature. We report an additional case with a brief review of the literature of a primary pulmonary angiosarcoma in a 26-year-old lady who presented with intractable hemoptysis. In addition, we highlight the potential of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography as an important diagnostic tool in the evaluation of this tumor and thus contribute to the existing sparse literature on this fascinating yet devastating disease

  3. Positron emission tomography/computed tomography predictors of overall survival in stage IIIC/IV ovarian cancer

    DEFF Research Database (Denmark)

    Risum, Signe; Loft, Annika; Engelholm, Svend Aage;

    2012-01-01

    To evaluate the role of 2-deoxy-2-(F)fluoro-D-glucose (FDG) positron emission tomography/computed tomography (PET/CT) for selecting patients with extensive ovarian cancer (OC) for neoadjuvant chemotherapy by evaluating predictors of overall survival in patients with stage IIIC/IV OC....

  4. In Vivo Treatment Sensitivity Testing With Positron Emission Tomography/Computed Tomography After One Cycle of Chemotherapy for Hodgkin Lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Kostakoglu, Lale; Zaucha, Jan Maciej;

    2014-01-01

    PURPOSE: Negative [(18)F]fluorodeoxyglucose (FDG) -positron emission tomography (PET)/computed tomography (CT) after two cycles of chemotherapy indicates a favorable prognosis in Hodgkin lymphoma (HL). We hypothesized that the negative predictive value would be even higher in patients responding...

  5. F-18 fluoro-d-glucose positron emission tomography/computed tomography in a patient with corticobasal degeneration

    International Nuclear Information System (INIS)

    Corticobasal degeneration is a rare neurodegenerative disorder that often eludes clinical diagnosis. The present case shows the F-18 fluoro-d-glucose positron emission tomography/computed tomography (PET/CT) of a 62-year-old man with a progressive movement disorder with asymmetric features. PET/CT examination showed a markedly right-brain hemispheric hypometabolism also involving basal ganglia

  6. Marked uptake of fluorodeoxyglucose in a vocal cord after medialization: Acute and subacute positron emission tomography/computed tomography findings

    International Nuclear Information System (INIS)

    A 60-year-old male who underwent left upper lobectomy because of recently diagnosed lung cancer was admitted to the nuclear medicine department. A whole body fluorodeoxyglucose positron emission tomography/computed tomography (CT) that was performed for staging purposes, revealed an intense hypermetabolism in left vocal cord region corresponding with hyperdense mass-like material on CT scan

  7. Report of two cases of fluorodeoxyglucose positron emission tomography/computed tomography appearance of hibernoma: A rare benign tumor

    International Nuclear Information System (INIS)

    False-positive findings are commonly seen in positron emission tomography computed tomography imaging. One of the most common false positive finding is uptake of fluorodeoxyglucose in brown adipose tissue. Herein, we report two cases with incidentally detected hibernomas-a brown fat containing tumor with metabolic activity

  8. Value of computed tomography in patients with mucopolysaccharidosis

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, J.; Grebell, F.S.

    1987-11-01

    Cranial computed tomography (CT) was performed on 11 cases of mucopolysaccharidosis (MPS) IVA (Morquio syndrome). Our results suggest that although having normal intelligence CT changes may be seen with increasing age. In two cases white matter low density was found and in a third there was gross dilatation of the ventricles, basal cisterns and subarachnoid space. Nine other patients with various types of mucopolysaccharidosis also had cranial CT performed and in general those types associated with mental retardation showed changes although there was an interesting exception involving a case of MPS IIIA who had a normal CT scan.

  9. The value of computed tomography in patients with mucopolysaccharidosis

    International Nuclear Information System (INIS)

    Cranial computed tomography (CT) was performed on 11 cases of mucopolysaccharidosis (MPS) IVA (Morquio syndrome). Our results suggest that although having normal intelligence CT changes may be seen with increasing age. In two cases white matter low density was found and in a third there was gross dilatation of the ventricles, basal cisterns and subarachnoid space. Nine other patients with various types of mucopolysaccharidosis also had cranial CT performed and in general those types associated with mental retardation showed changes although there was an interesting exception involving a case of MPS IIIA who had a normal CT scan. (orig.)

  10. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    Directory of Open Access Journals (Sweden)

    João Palas

    2014-01-01

    Full Text Available Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  11. Synovial plicae of the knee on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Boven, F.; De Boeck, M.; Potvliege, R.

    1983-06-01

    Computed tomography (CT) of the knee was performed in 160 patients following double-contrast arthrography. Seventy-five synovial folds on the medial wall of the knee joint were found, and 63 of these plicae could be considered mediopatellar plicae. In 10 on the 63 cases, long, thick, mediopatellar plicae were found, which could lead to a mechanical internal derangement. Twelve synovial folds did not conform to the classic description of a mediopatellar plica. These folds probably represent synovial tissue reaction, since they were most commonly seen in patients who had undergone meniscectomy.

  12. Prognostic value of computed tomography in acute pancreatis

    Energy Technology Data Exchange (ETDEWEB)

    Grabbe, E.; Dammann, H.G.; Heller, M.

    1982-05-01

    A prospective study was performed in 59 patients with acute pancreatitis to find out the value of computed tomography for an early prognosis. CT findings (retroperitoneal fluid collections with enlargement of the retroperitoneal space, intraperitoneal air-fluid levels and ascites), clinical (age, ileus) and laboratory tests (LDH, blood glucose, urea, creatinine and calcium) were taken into consideration. These data were collected during the first two days after hospitalisation and turned out to be of considerable prognostic value: about 70% of the patients died when 5 or more of these pathological findings exist. More than 90% of all patients who died belonged to this group.

  13. Computed tomography and magnetic resonance imaging evaluation of pericardial disease.

    Science.gov (United States)

    Hoey, Edward T D; Shahid, Muhammad; Watkin, Richard W

    2016-06-01

    Pericardial diseases are commonly encountered in clinical practice and may present as an isolated process or in association with various systemic conditions. Traditionally transthoracic echocardiography (TTE) has been the method of choice for the evaluation of suspected pericardial disease but increasingly computed tomography (CT) and magnetic resonance imaging (MRI) are also being used as part of a rational multi-modality imaging approach tailored to the specific clinical scenario. This paper reviews the role of CT and MRI across the spectrum of pericardial diseases. PMID:27429911

  14. A proton Computed Tomography system for medical applications

    Science.gov (United States)

    Sipala, V.; Bruzzi, M.; Bucciolini, M.; Carpinelli, M.; Cirrone, G. A. P.; Civinini, C.; Cuttone, G.; Lo Presti, D.; Pallotta, S.; Pugliatti, C.; Randazzo, N.; Romano, F.; Scaringella, M.; Stancampiano, C.; Talamonti, C.; Tesi, M.; Vanzi, E.; Zani, M.

    2013-02-01

    Proton Computed Tomography (pCT) can improve the accuracy of both patient positioning and dose calculation in proton therapy, enabling to accurately reconstruct the electron density distribution of irradiated tissues. A pCT prototype, equipped with a silicon tracker and a YAG:Ce calorimeter, has been manufactured by an Italian collaboration. First tests under proton beam allowed obtaining good quality tomographic images of a non-homogeneous phantom. Manufacturing of a new large area system with real-time data acquisition is under way.

  15. PRaVDA: High Energy Physics towards proton Computed Tomography

    Science.gov (United States)

    Price, T.

    2016-07-01

    Proton radiotherapy is an increasingly popular modality for treating cancers of the head and neck, and in paediatrics. To maximise the potential of proton radiotherapy it is essential to know the distribution, and more importantly the proton stopping powers, of the body tissues between the proton beam and the tumour. A stopping power map could be measured directly, and uncertainties in the treatment vastly reduce, if the patient was imaged with protons instead of conventional x-rays. Here we outline the application of technologies developed for High Energy Physics to provide clinical-quality proton Computed Tomography, in so reducing range uncertainties and enhancing the treatment of cancer.

  16. 3D artefact for concurrent scale calibration in Computed Tomography

    DEFF Research Database (Denmark)

    Stolfi, Alessandro; De Chiffre, Leonardo

    2016-01-01

    A novel artefact for calibration of the scale in 3D X-ray Computed Tomography (CT) is presented. The artefact comprises a carbon fibre tubular structure on which a number of reference ruby spheres are glued. The artefact is positioned and scanned together with the workpiece inside the CT scanner...... providing a reference system for measurement. The artefact allows a considerable reduction of time by compressing the full process of calibration, scanning, measurement, and re-calibration, into a single process. The method allows a considerable reduction of the amount of data generated from CT scanning...

  17. Computed Tomography Appearances of Various Complications Associated with Pancreatic Pseudocysts

    Energy Technology Data Exchange (ETDEWEB)

    Cheol Kim, Hyun; Mo Yang, Dal; Jung Kim, Hyoung; Ho Lee, Dong; Tae Ko, Young; Won Lim, Joo (Dept. of Radiology, East-West Neo Medical Center, Kyung-Hee Univ., Seoul (Korea))

    2008-09-15

    Most pancreatic pseudocysts are common complications of acute or chronic pancreatitis. They usually occur within the pancreas or in peripancreatic tissues, and are visualized as round or oval fluid collections with thin or thick walls on computed tomography (CT) scans. However, pancreatic pseudocysts are often combined with various complications, e.g., various organ involvements, infection, hemorrhage with pseudoaneurysm formation, rupture with fistula formation, or gastrointestinal or biliary obstruction, which may necessitate prompt intervention or surgery. This review illustrates the CT appearances of various complications associated with pancreatic pseudocysts

  18. Quantification of salt concentrations in cured pork by computed tomography

    DEFF Research Database (Denmark)

    Vestergaard, Christian Sylvest; Risum, Jørgen; Adler-Nissen, Jens

    2004-01-01

    Eight pork loin samples were mounted in Plexiglas cylinders and cured for five days. Samples were scanned by computed tomography (CT) once every 24 h. At the end of the experiment, the cylinders were cut in 1 cm sections and analyzed for chloride. From image analysis of the CT images, concentration...... profiles were extracted and fitted to a diffusion model which included a term to account for a non-negligible mass transfer coefficient. It was found that CT provides accurate estimates of salt gradients in meat and it was suggested that this analytical method could be valuable in scientific research and...

  19. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    International Nuclear Information System (INIS)

    Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  20. An evaluation of cadmium telluride detectors for computer assisted tomography.

    Science.gov (United States)

    Chu, D; Kaufman, L; Hosier, K; Hoenninger, J

    1978-11-01

    Cadmium telluride (CdTe) presents a set of extremely attractive features as an X-ray detector for computer assisted tomography (CAT). It is stable and easily handled; has a high detection efficiency and very efficient conversion of energy to charge; and permits a high element density in a compact configuration. Unfortunately, effects due to "polarization," "tailing," high and variable leakage currents, and long "memory" are incompatible with the needs of CAT instrumentation. Pulse-processing techniques have allowed us to eliminate these problems in positive-sensitive detectors, thus opening the way for utilization of CdTe in CAT. PMID:711945

  1. Compressive sampling in computed tomography: Method and application

    International Nuclear Information System (INIS)

    Since Donoho and Candes et al. published their groundbreaking work on compressive sampling or compressive sensing (CS), CS theory has attracted a lot of attention and become a hot topic, especially in biomedical imaging. Specifically, some CS based methods have been developed to enable accurate reconstruction from sparse data in computed tomography (CT) imaging. In this paper, we will review the progress in CS based CT from aspects of three fundamental requirements of CS: sparse representation, incoherent sampling and reconstruction algorithm. In addition, some potential applications of compressive sampling in CT are introduced

  2. X-ray computed tomography investigations of Cucuteni ceramic statuettes

    Directory of Open Access Journals (Sweden)

    Carmen Pavel

    2013-12-01

    Full Text Available Deciphering the internal structure of prehistoric artefacts can provide spectacular insights that might help us understand the people who made them. In order to preserve the integrity of these relics of past civilisations, it is desirable to make such investigations using non-destructive techniques. Recent decades have witnessed a growth in the X-ray computed tomography (CT applications in the study of cultural heritage objects. This paper presents and discusses tomographic investigations of two Cucuteni ceramic statuettes discovered in Romania. The study was made with a CT device specially designed for archaeometric applications.

  3. Application of computer assisted tomography in gynaecological oncology

    International Nuclear Information System (INIS)

    The non invasive radiologic technique of computed tomography has been employed since 1978 at the University Women's Clinic and Radiologic Clinic, Graz. One hundred and fourty six examinations of the pelvis, abdomen and chest were performed on 63 oncologic patients. The method was employed for the preoperative detection and measurement of the size of benign and malignant neoplasms; in tumour staging and assessment of therapeutic response. The results suggest that CT might be the best method for the assessment of response to cytotoxic therapy of ovarian cancer. (orig.)

  4. [THE ROLE OF COMPUTER TOMOGRAPHY WHILE CHOOSING THE ABDOMINOPLASTY METHOD].

    Science.gov (United States)

    Galych, S P; Symulyk, E V

    2016-03-01

    The role of computer tomography (CT), while choosing the abdominoplasty method in the patients with different types of the anterior abdominal wall deformity present. For CT date the anterior abdominal wall deformity type was determined in the accordance to it--the operation volume needed. Depending on the changes degree the patients were divided on 5 groups, and in accordance to the deformity type present a necessary correction was made. The CT application have had permitted to determine the changes degree in the anterior abdominal wall, and to choose a necessary volume of abdominoplasty precisely. PMID:27514090

  5. Computed tomography scanner applied to soil compaction studies

    International Nuclear Information System (INIS)

    The soil compaction problem was studied using a first generation computed tomography scanner (CT). This apparatus gets images of soil cross sections samples, with resolution of a few millimeters. We performed the following laboratory and field experiments: basic experiments of equipment calibrations and resolutions studies; measurements of compacted soil thin layers; measurements of soil compaction caused by agricultural tools; stress-strain modelling in confined soil sample, with several moisture degree; characterizations of soil bulk density profile with samples collected in a hole (trench), comparing with a cone penetrometer technique. (author)

  6. Reduction of phase artifacts in differential phase contrast computed tomography.

    Science.gov (United States)

    Jerjen, Iwan; Revol, Vincent; Schuetz, Philipp; Kottler, Christian; Kaufmann, Rolf; Luethi, Thomas; Jefimovs, Konstantins; Urban, Claus; Sennhauser, Urs

    2011-07-01

    X-ray differential phase contrast computed tomography (DPC CT) with a Talbot-Lau interferometer setup allows visualizing the three-dimensional distribution of the refractive index by measuring the shifts of an interference pattern due to phase variations of the X-ray beam. Unfortunately, severe reconstruction artifacts appear in the presence of differential phase wrapping and clipping. In this paper, we propose to use the attenuation contrast, which is obtained from the same measurement, for correcting the DPC signal. Using the example of a DPC CT measurement with pronounced phase artifacts, we will discuss the efficiency of our phase artifact correction method. PMID:21747516

  7. Compressive sampling in computed tomography: Method and application

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Zhanli [Paul Lauterbur Center for Biomedical Imaging Research, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen (China); Beijing Center for Mathematics and Information Interdisciplinary Sciences, Beijing (China); Shenzhen Key Lab for Molecular Imaging, Shenzhen (China); Liang, Dong, E-mail: dong.liang@siat.ac.cn [Paul Lauterbur Center for Biomedical Imaging Research, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen (China); Beijing Center for Mathematics and Information Interdisciplinary Sciences, Beijing (China); Xia, Dan [University of Pennsylvania, Philadelphia (United States); Zheng, Hairong [Paul Lauterbur Center for Biomedical Imaging Research, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen (China); Beijing Center for Mathematics and Information Interdisciplinary Sciences, Beijing (China)

    2014-06-01

    Since Donoho and Candes et al. published their groundbreaking work on compressive sampling or compressive sensing (CS), CS theory has attracted a lot of attention and become a hot topic, especially in biomedical imaging. Specifically, some CS based methods have been developed to enable accurate reconstruction from sparse data in computed tomography (CT) imaging. In this paper, we will review the progress in CS based CT from aspects of three fundamental requirements of CS: sparse representation, incoherent sampling and reconstruction algorithm. In addition, some potential applications of compressive sampling in CT are introduced.

  8. Pathological evaluation of computed tomography images of lungs.

    OpenAIRE

    Coddington, R; Mera, S L; Goddard, P R; Bradfield, J W

    1982-01-01

    A method is described which allows the features seen in images generated during computed tomography (CT) of lungs previously removed at necropsy to be compared with those seen in corresponding thin sections made from the same lungs. After removal from the body, lungs were inflation-fixed using warm formalin vapour before being x-rayed and then scanned in the inflated state. Slices corresponding to the CT scan images were made and x-rayed. Paper mounted sections were then prepared from each sl...

  9. Clinical experience with the first combined positron emission tomography/computed tomography scanner in Australia.

    Science.gov (United States)

    Lau, W F Eddie; Binns, David S; Ware, Robert E; Ramdave, Shakher; Cachin, Florent; Pitman, Alexander G; Hicks, Rodney J

    2005-02-21

    Metabolic imaging with fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) is increasing rapidly worldwide because of superior accuracy compared with conventional non-invasive techniques used for evaluating cancer. Limited anatomical information from FDG-PET images alone dictates that complementary use with structural imaging is required to optimise benefit. Recently, combined positron emission tomography/computed tomography (PET/CT) scanners have overtaken standalone PET scanners as the most commonly purchased PET devices. We describe our experience of over 5500 scans performed since the first PET/CT scanner in Australia was commissioned at the Peter MacCallum Cancer Centre (PMCC), Melbourne, in January 2002. Clinical indications for PET/CT scans performed at PMCC largely reflect current Medicare reimbursement policy. Advantages of PET/CT include greater patient comfort and higher throughput, greater diagnostic certainty and accuracy, improved biopsy methods, and better treatment planning. We believe PET/CT will underpin more effective and efficient imaging paradigms for many common tumours, and lead to a decrease in imaging costs. PMID:15720173

  10. Usefulness of tomography with a compensating filter and computed tomography after pneumomediastinography

    Energy Technology Data Exchange (ETDEWEB)

    Yamakawa, Kimiko (Yamaguchi Univ., Ube (Japan). School of Medicine)

    1989-08-01

    Author attempted tomography with a compensating filter and computed tomography (CT) after pneumomediastinography (PMG) to assess mediastinum-related lesions. Author found the results as follows. The tomography with a compensating filter after PMG was especially useful for evaluating the left paratracheal, tracheobronchial lymph node swelling. On the lateral tomogram after PMG, thymus and pretracheal, retrotracheal stripe were well demonstrated. Comparative studies with plain and/or enhanced CT and CT after PMG were made on the invasion and/or adhesion to the neighboring structures. On the plain and/or enhanced CT, we could diagnose with 61% sensitivity, 100% specificity, and 74% accuracy. On the other hand, we could diagnose with 80% sensitivity, 100% specificity, and 90% accuracy on the CT after PMG. Therefore, this method proved to be very useful for diagnosing the mediastinal invasion and/or adhesions. Visualization of the pleura by this method is useful to differentiate pulmonary lesions from mediastinal lesions. These results suggest that this method would be considered to be advantagenous and advisable in evaluating mediastinum-related lesions. (author).

  11. Benign breast lesions detected by positron emission tomography-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Benveniste, Ana P., E-mail: apbenveniste@mdanderson.org [Department of Diagnostic Radiology,The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Yang, Wei, E-mail: wyang@mdanderson.org [Department of Diagnostic Radiology,The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Benveniste, Marcelo F., E-mail: mfbenveniste@mdanderson.org [Department of Diagnostic Radiology,The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Mawlawi, Osama R., E-mail: omawlawi@mdanderson.org [Department of imaging physics, The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Marom, Edith M., E-mail: emarom@mdanderson.org [Department of Diagnostic Radiology,The University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2014-06-15

    {sup 18}F-fluorodeoxyglucose positron emission computed tomography (FDG PET-CT) is widely used in the initial staging and response evaluation of patients with malignancy. This review describes a spectrum of benign breast findings incidentally detected by FDG PET-CT at staging that may be misinterpreted as malignancy. We describe the pattern of distribution and intensity of FDG uptake in a spectrum of benign breast diseases with their corresponding typical morphological imaging characteristics to help the nuclear medicine physician and/or general radiologist identify benign lesions, avoiding unnecessary breast imaging work-up and biopsies.

  12. Position emission tomography with or without computed tomography in the primary staging of Hodgkin's lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Loft, Annika; Hansen, Mads;

    2006-01-01

    BACKGROUND AND OBJECTIVES: In order to receive the most appropriate therapy, patients with Hodgkin's lymphoma (HL) must be accurately stratified into different prognostic staging groups. Computed tomography (CT) plays a pivotal role in the conventional staging. The aim of the present study...... in their staging work-up. Sixty-one of the 99 patients had combined FDG-PET/CT. A standard of reference for each nodal region and organ was determined using all available information including scan results, histology and a minimum of one year's clinical follow-up data. The lack of a satisfactory diagnostic gold...

  13. Computed Tomography and Computed Radiography of late Bronze Age Cremation Urns from Denmark

    DEFF Research Database (Denmark)

    Harvig, Lise Lock; Lynnerup, Niels; Amsgaard Ebsen, Jannie

    2012-01-01

    To improve methods used to study prehistoric cremation rituals, cremation urns from the Danish late Bronze Age were examined using Computed Tomography and Computed Radiography (Digital X-ray). During microexcavation, the digital images were used as registration tool. Our results suggest that oste...... intensity show markedly poorer preservation and recovery than white calcined fragments do. Thus post-excavation estimations of cremation intensity are systematically biased...

  14. 'Chasing the Dragon' - imaging of heroin inhalation leukoencephalopathy

    International Nuclear Information System (INIS)

    'Chasing the dragon' refers to the inhalation of heroin pyrolysate vapors produced when the freebase form of heroin is heated. Inhalation of these vapors can result in a rare toxic spongiform leukoencephalopathy. The patients may progress through 3 defined clinical stages, with one-quarter reaching the terminal stage, which invariably leads to death. Imaging and, in particular, magnetic resonance imaging (MRI) demonstrates white matter findings that are felt to be specific for this entity and essential in its early diagnosis. We present the typical imaging findings in a pictorial essay format, using images taken from 9 patients who presented within an 18-month period at UBC-affiliated hospitals. These findings include low computed tomography (CT) attenuation and high T2 MRI signal most commonly in the posterior cerebral and cerebellar white matter, cerebellar peduncles, splenium of the corpus callosum, and posterior limb of the internal capsules. In addition, there is often selective, symmetric involvement of the corticospinal tract, the medial lemniscus, and the tractus solitarius. We also present the variable diffusion-weighted imaging arid apparent diffusion coefficient findings from 4 of our patients, which to our knowledge, have not been described in the literature. (author)

  15. Radiation doses from computed tomography practice in Johor Bahru, Malaysia

    Science.gov (United States)

    Karim, M. K. A.; Hashim, S.; Bradley, D. A.; Bakar, K. A.; Haron, M. R.; Kayun, Z.

    2016-04-01

    Radiation doses for Computed Tomography (CT) procedures have been reported, encompassing a total of 376 CT examinations conducted in one oncology centre (Hospital Sultan Ismail) and three diagnostic imaging departments (Hospital Sultanah Aminah, Hospital Permai and Hospital Sultan Ismail) at Johor hospital's. In each case, dose evaluations were supported by data from patient questionnaires. Each CT examination and radiation doses were verified using the CT EXPO (Ver. 2.3.1, Germany) simulation software. Results are presented in terms of the weighted computed tomography dose index (CTDIw), dose length product (DLP) and effective dose (E). The mean values of CTDIw, DLP and E were ranged between 7.6±0.1 to 64.8±16.5 mGy, 170.2±79.2 to 943.3±202.3 mGy cm and 1.6±0.7 to 11.2±6.5 mSv, respectively. Optimization techniques in CT are suggested to remain necessary, with well-trained radiology personnel remaining at the forefront of such efforts.

  16. Incidental cardiac findings on computed tomography imaging of the thorax

    Directory of Open Access Journals (Sweden)

    El-Gendi Hossam

    2010-12-01

    Full Text Available Abstract Background Investigation of pulmonary pathology with computed tomography also allows visualisation of the heart and major vessels. We sought to explore whether clinically relevant cardiac pathology could be identified on computed tomography pulmonary angiograms (CTPA requested for the exclusion of pulmonary embolism (PE. 100 consecutive CT contrast-enhanced pulmonary angiograms carried out for exclusion of PE at a single centre were assessed retrospectively by two cardiologists. Findings Evidence of PE was reported in 5% of scans. Incidental cardiac findings included: aortic wall calcification (54%, coronary calcification (46%, cardiomegaly (41%, atrial dilatation (18%, mitral annulus calcification (15%, right ventricular dilatation (11%, aortic dilatation (8% and right ventricular thrombus (1%. Apart from 3 (3% reports describing cardiomegaly, no other cardiac findings were described in radiologists' reports. Other reported pulmonary abnormalities included: lung nodules (14%, lobar collapse/consolidation (8%, pleural effusion (2%, lobar collapse/consolidation (8%, emphysema (6% and pleural calcification (4%. Conclusions CTPAs requested for the exclusion of PE have a high yield of cardiac abnormalities. Although these abnormalities may not have implications for acute clinical management, they may, nevertheless, be important in long-term care.

  17. Computed tomography angiography in patients with active gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Fatima Regina Silva; D' Ippolito, Giuseppe, E-mail: fatima.rsreis@gmail.com [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina; Cardia, P.P. [Hospital Vera Cruz, Campinas, SP (Brazil)

    2015-11-15

    Gastrointestinal bleeding represents a common medical emergency, with considerable morbidity and mortality rates, and a prompt diagnosis is essential for a better prognosis. In such a context, endoscopy is the main diagnostic tool; however, in cases where the gastrointestinal hemorrhage is massive, the exact bleeding site might go undetected. In addition, a trained professional is not always present to perform the procedure. In an emergency setting, optical colonoscopy presents limitations connected with the absence of bowel preparation, so most of the small bowel cannot be assessed. Scintigraphy cannot accurately demonstrate the anatomic location of the bleeding and is not available at emergency settings. The use of capsule endoscopy is inappropriate in the acute setting, particularly in the emergency department at night, and is a highly expensive method. Digital angiography, despite its high sensitivity, is invasive, presents catheterization-related risks, in addition to its low availability at emergency settings. On the other hand, computed tomography angiography is fast, widely available and minimally invasive, emerging as a promising method in the diagnostic algorithm of these patients, being capable of determining the location and cause of bleeding with high accuracy. Based on a critical literature review and on their own experience, the authors propose a computed tomography angiography protocol to assess the patient with gastrointestinal bleeding. (author)

  18. Neutron computed tomography of plasma facing components for fusion experiments

    International Nuclear Information System (INIS)

    In nuclear fusion experiments, divertor plates are used to remove energy and particles from the plasma. These divertor plates can be made of water-cooled copper heat sinks covered by carbon fiber composite (CFC) protection tiles. During operation, surface temperatures in excess of 1000 oC are reached for typical heat loads of 10 MW/m2. The large mismatch in the coefficients of thermal expansion for CFC and Cu causes high stresses and possibly bonding defects. Growing joint defects, which lead to unacceptable overheating of the protection tiles, are critical for the lifetime of the components. A prototype component was subjected to 10,000 cycles at 10 MW/m2 to study the crack growth mechanism. Neutron computed tomography offers the possibility to analyze such structures on centimeter-sized samples non-destructively with a high spatial resolution. At the ANTARES neutron imaging facility of the FRM II reactor, the samples were loaded with a contrast agent and examined with neutron computed tomography.

  19. Computed tomography of nonanesthetized cats with upper airway obstruction.

    Science.gov (United States)

    Stadler, Krystina; O'Brien, Robert

    2013-01-01

    Upper airway obstruction is a potentially life-threatening problem in cats and for which a noninvasive, sensitive method rapid diagnosis is needed. The purposes of this prospective study were to describe a computed tomography (CT) technique for nonanesthetized cats with upper airway obstruction, CT characteristics of obstructive diseases, and comparisons between CT findings and findings from other diagnostic tests. Ten cats with clinical signs of upper airway obstruction were recruited for the study. Four cats with no clinical signs of upper airway obstruction were recruited as controls. All cats underwent computed tomography imaging without sedation or anesthesia, using a 16-slice helical CT scanner and a previously described transparent positional device. Three-dimensional (3D) internal volume rendering was performed on all CT image sets and 3D external volume rendering was also performed on cats with evidence of mass lesions. Confirmation of upper airway obstruction was based on visual laryngeal examination, endoscopy, fine-needle aspirate, biopsy, or necropsy. Seven cats were diagnosed with intramural upper airway masses, two with laryngotracheitis, and one with laryngeal paralysis. The CT and 3D volume-rendered images identified lesions consistent with upper airway disease in all cats. In cats with mass lesions, CT accurately identified the mass and location. Findings from this study supported the use of CT imaging as an effective technique for diagnosing upper airway obstruction in nonanesthetized cats. PMID:23441677

  20. X-ray computed tomography using curvelet sparse regularization

    Energy Technology Data Exchange (ETDEWEB)

    Wieczorek, Matthias, E-mail: wieczore@cs.tum.edu; Vogel, Jakob; Lasser, Tobias [Chair for Computer Aided Medical Procedures (CAMP), Technische Universität München, 85748, Garching (Germany); Frikel, Jürgen; Demaret, Laurent [Institute of Computational Biology, Helmholtz Zentrum München, 85764, Neuherberg (Germany); Eggl, Elena; Pfeiffer, Franz [Lehrstuhl für Biomedizinische Physik, Physik-Department and Institut für Medizintechnik, Technische Universität München, 85748, Garching (Germany); Kopp, Felix; Noël, Peter B. [Department of Diagnostic and Interventional Radiology, Klinikum Rechts der Isar, Technische Universität München, 81675, München (Germany)

    2015-04-15

    Purpose: Reconstruction of x-ray computed tomography (CT) data remains a mathematically challenging problem in medical imaging. Complementing the standard analytical reconstruction methods, sparse regularization is growing in importance, as it allows inclusion of prior knowledge. The paper presents a method for sparse regularization based on the curvelet frame for the application to iterative reconstruction in x-ray computed tomography. Methods: In this work, the authors present an iterative reconstruction approach based on the alternating direction method of multipliers using curvelet sparse regularization. Results: Evaluation of the method is performed on a specifically crafted numerical phantom dataset to highlight the method’s strengths. Additional evaluation is performed on two real datasets from commercial scanners with different noise characteristics, a clinical bone sample acquired in a micro-CT and a human abdomen scanned in a diagnostic CT. The results clearly illustrate that curvelet sparse regularization has characteristic strengths. In particular, it improves the restoration and resolution of highly directional, high contrast features with smooth contrast variations. The authors also compare this approach to the popular technique of total variation and to traditional filtered backprojection. Conclusions: The authors conclude that curvelet sparse regularization is able to improve reconstruction quality by reducing noise while preserving highly directional features.

  1. High resolution muon computed tomography at neutrino beam facilities

    International Nuclear Information System (INIS)

    X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires higher resolution in the muon spectrometer to resolve the image. The variance of the measured muon momentum reaches a minimum and then increases with increasing muon momentum. The impact of the increase in variance is to require a higher integrated muon flux to reduce fluctuations. The flux requirements and level of contrast needed for high resolution muon computed tomography are well matched to the muons produced in the pion decay pipe at a neutrino beam facility and what can be achieved for momentum resolution in a muon spectrometer. Such an imaging system can be applied in archaeology, art history, engineering, material identification and whenever there is a need to image inside a transportable object constructed of dense materials

  2. Low dose computed tomography in suspected acute renal colic

    Energy Technology Data Exchange (ETDEWEB)

    Meagher, Tom; Sukumar, V.P.; Collingwood, Jackie; Crawley, Therese; Schofield, David; Henson, John; Lakin, Ken; Connolly, Dan; Giles, John

    2001-11-01

    Aim: To evaluate whether computed tomography (CT) of the renal tract in suspected renal colic using reduced exposure factors maintains diagnostic accuracy. METHODS: Prospective multi-centre cohort study. Patients with suspected renal colic were examined using computed tomography (CT) of the renal tract followed by intravenous urography (IVU) in four different centres with five different CT systems. RESULTS: Sixty-nine patients with suspected renal colic had CT of the renal tract followed by IVU. CT was performed with reduced exposure factors, giving a mean CT effective dose of 3.5 (range 2.8-4.5) mSv compared with 1.5 mSv for IVU. Ureteric calculi were detected in 43 patients: CT and IVU detected 40 (93%) ureteric calculi. CT identified other lesions causing symptoms in five patients and identified renal calculi in 24 patients. IVU identified renal calculi in six patients and made false positive diagnosis of renal calculi in seven patients. Mean examination time for CT was 5 minutes and for IVU was 80 minutes. CONCLUSION: CT examination at reduced exposure factors maintains the diagnostic accuracy recorded in other series. Meagher, T. et al. (2001)

  3. Computed tomography in evaluation of revision hip arthroplasty outcomes.

    Science.gov (United States)

    Kochman, Andrzej; Morawska-Kochman, Monika; Guziński, Maciej; Drobniewski, Marek; Sibiński, Marcin; Synder, Marek

    2014-01-01

    Background. This study aimed to assess contact between Recon Shell reinforcement cages used in revision hip arthroplasty and the bony base. Radiographic examinations were performed with the use of multi-energy computed tomography. Material and methods. We tentatively assess the fixation of Burch-Schneider reinforcement cages (Recon Shell made by Aesculap company) implanted in 10 patients, using two methods of evaluation. An analysis of dual energy CT scans enabled us to assess contact between the reinforcement cages and the bony base. Results. The two methods of evaluation produced different results. The evaluation method based on the division of the acetabular component into a weight-bearing zone and a non-weight-bearing zone (accounting for screw fixation) showed lack of support in the weight-bearing zone in 6 out of 10 cases and direct contact with the implant bed in only one case. The assessment of contact at anchorage holes of reinforcement cages fixed at primary procedures revealed no such support in only one case and the presence of direct contact in 5 cases. There was no correlation between the radiological outcomes and clinical results based on the Harris Hip Score. Conclusions. 1. Multi-energy computed tomography (MARS) is useful in evaluating results of revision hip allo-plasty. 2. The introduction of new imaging techniques for the evaluation of revision procedures demonstrates a need for new, unified methods of outcome assessment adjusted to the characteristics of a particular procedure. PMID:25406920

  4. Computed tomography angiography in patients with active gastrointestinal bleeding

    Directory of Open Access Journals (Sweden)

    Fatima Regina Silva Reis

    2015-12-01

    Full Text Available Abstract Gastrointestinal bleeding represents a common medical emergency, with considerable morbidity and mortality rates, and a prompt diagnosis is essential for a better prognosis. In such a context, endoscopy is the main diagnostic tool; however, in cases where the gastrointestinal hemorrhage is massive, the exact bleeding site might go undetected. In addition, a trained professional is not always present to perform the procedure. In an emergency setting, optical colonoscopy presents limitations connected with the absence of bowel preparation, so most of the small bowel cannot be assessed. Scintigraphy cannot accurately demonstrate the anatomic location of the bleeding and is not available at emergency settings. The use of capsule endoscopy is inappropriate in the acute setting, particularly in the emergency department at night, and is a highly expensive method. Digital angiography, despite its high sensitivity, is invasive, presents catheterization-related risks, in addition to its low availability at emergency settings. On the other hand, computed tomography angiography is fast, widely available and minimally invasive, emerging as a promising method in the diagnostic algorithm of these patients, being capable of determining the location and cause of bleeding with high accuracy. Based on a critical literature review and on their own experience, the authors propose a computed tomography angiography protocol to assess the patient with gastrointestinal bleeding.

  5. Computed tomography of intra - and extramural ethmoid cells: iconographic essay

    International Nuclear Information System (INIS)

    The development of the paranasal sinuses is an intricate process that begins in the intrauterine life and terminates in early adulthood. Among the paranasal sinuses, the ethmoid cells or labyrinth are probably the most complex structures, being associated with the highest number of normal variants. Variations in the pattern of pneumatization of the ethmoid cells can be divided into intra - and extramural cells. Intramural cells are those which develop within the ethmoid labyrinth. Extramural cells are those that develop isolatedly. Computed tomography is the most useful tool in the evaluation of inflammatory processes of the paranasal sinuses. Computed tomography also plays a relevant role in the preoperative planning as well as in the postoperative follow-up, since it demonstrates exact anatomical details of normal structures with accuracy in the detection of variants. In the present pictorial essay, the authors describe the most common anatomical variants of the ethmoid labyrinth and their relationship with adjacent structures. Endoscopic sinonasal surgery has become increasingly less invasive, requiring more detailed anatomical imaging of this region. (author)

  6. Measurement of spleen by computed tomography in normal Korean adults

    International Nuclear Information System (INIS)

    Computed tomography potentially offers the most accurate noninvasive method of estimating volume of a solid organ in vivo. The study was undertaken to obtain standard values of size, volume and mass of normal spleen in Korean adults. The authors analysed 109 cases of abdominal computed tomography of normal Korean adults. The results were as follows; 1. The average splenic volume in adults was 173.17 ± 59.02 cm3 in male, 160.43 ± 61.72 cm3 in female and total average, 160.98 ± 60.41 cm3. 2. The average splenic mass in adults were 181.20 ± 61.16 gm in male, 166.44 ± 64.68 gm in female and total average, 174 ± 63.0 gm. 3. The average size of the spleen in adult males was 9.39 ± 1.33 cm in breath, 3.8 ± 0.69 cm in thickness, and 7.97 ± 1.43 cm in height; in adult females, 9.25 ± 1.46 cm,3.51 ± 0.65 cm, 8.05 ± 1.35 cm,respectively; total average, 9.32 ± 1.39 cm, 3.70 ± 0.60 cm, 8.01 ± 1.39 cm, respectively. 4. There was no statistical difference of volume, mass and size between sex and age

  7. Computed tomography findings of paracoccidiodomycosis in musculoskeletal system

    Energy Technology Data Exchange (ETDEWEB)

    Lima Junior, Francisco Valtenor Araujo; Savarese, Leonor Garbin; Monsignore, Lucas Moretti; Martinez, Roberto; Nogueira-Barbosa, Marcello Henrique, E-mail: fvaltenor@gmail.com [Universidade de Sao Paulo (FM/USP), Ribeirao Preto, SP (Brazil). Fac. de Medicina

    2015-01-15

    Objective: to evaluate musculoskeletal involvement in paracoccidioidomycosis at computed tomography. Materials and methods: development of a retrospective study based on a review of radiologic and pathologic reports in the institution database. Patients with histopathologically confirmed musculoskeletal paracoccidioidomycosis and submitted to computed tomography were included in the present study. The imaging findings were consensually described by two radiologists. In order to avoid bias in the analysis, one patient with uncountable bone lesions was excluded from the study. Results: a total of seven patients were included in the present study. A total of 18 bone lesions were counted. The study group consisted of 7 patients. A total number of 18 bone lesions were counted. Osteoarticular lesions were the first manifestation of the disease in four patients (57.14%). Bone lesions were multiple in 42.85% of patients. Appendicular and axial skeleton were affected in 85.71% and 42.85% of cases, respectively. Bone involvement was characterized by well-demarcated osteolytic lesions. Marginal osteosclerosis was identified in 72.22% of the lesions, while lamellar periosteal reaction and soft tissue component were present in 5.55% of them. One patient showed multiple small lesions with bone sequestra. Conclusion: paracoccidioidomycosis can be included in the differential diagnosis of either single or multiple osteolytic lesions in young patients even in the absence of a previous diagnosis of pulmonary or visceral paracoccidioidomycosis. (author)

  8. Pulmonary involvement in ankylosing spondylitis assessed by multidetector computed tomography

    International Nuclear Information System (INIS)

    Ankylosing spondylitis (AS) may present with extra-articular involvement in the lungs. We aimed to evaluate the abnormal pulmonary multidetector computed tomography findings of patients with AS and compare them with the clinical symptoms, duration of illness, laboratory results and pulmonary function tests (PFT). We evaluated the chest multidetector computed tomography (MDCT) findings of 41 patients with ankylosing spondylitis (AS) and compared them with pulmonary function test (PFT) results, demographic characteristics, duration of illness and laboratory findings that we were able to obtain. The most common abnormalities were nodules, peribronchial thickening, pleural thickening and bronchiectasis. Abnormalities occurred in 96.87% of patients in the early AS group and 77.8% of patients in the late AS group. Patients with early AS included asymptomatic individuals with normal PFT results and abnormal MDCT findings. The use of MDCT in AS patients may be beneficial for the evaluation of pulmonary disease, even in asymptomatic patients without any PFT abnormalities and those in the early stages of the disease

  9. Use of cone beam computed tomography in periodontology.

    Science.gov (United States)

    Acar, Buket; Kamburoğlu, Kıvanç

    2014-05-28

    Diagnosis of periodontal disease mainly depends on clinical signs and symptoms. However, in the case of bone destruction, radiographs are valuable diagnostic tools as an adjunct to the clinical examination. Two dimensional periapical and panoramic radiographs are routinely used for diagnosing periodontal bone levels. In two dimensional imaging, evaluation of bone craters, lamina dura and periodontal bone level is limited by projection geometry and superpositions of adjacent anatomical structures. Those limitations of 2D radiographs can be eliminated by three-dimensional imaging techniques such as computed tomography. Cone beam computed tomography (CBCT) generates 3D volumetric images and is also commonly used in dentistry. All CBCT units provide axial, coronal and sagittal multi-planar reconstructed images without magnification. Also, panoramic images without distortion and magnification can be generated with curved planar reformation. CBCT displays 3D images that are necessary for the diagnosis of intra bony defects, furcation involvements and buccal/lingual bone destructions. CBCT applications provide obvious benefits in periodontics, however; it should be used only in correct indications considering the necessity and the potential hazards of the examination.

  10. Computed tomography of intra - and extramural ethmoid cells: iconographic essay

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Fabricio Guimaraes [McGill University Health Centre (MUHC), Montreal, QC (Canada). Montreal General Hospital; Jovem, Cassio Lemos [Med Imagem, Teresina, PI (Brazil); Moura, Leonardo de Oliveira [Centro de Treinamento em Imagenologia (CETRIM), Joao Pessoa, PB (Brazil)

    2011-09-15

    The development of the paranasal sinuses is an intricate process that begins in the intrauterine life and terminates in early adulthood. Among the paranasal sinuses, the ethmoid cells or labyrinth are probably the most complex structures, being associated with the highest number of normal variants. Variations in the pattern of pneumatization of the ethmoid cells can be divided into intra - and extramural cells. Intramural cells are those which develop within the ethmoid labyrinth. Extramural cells are those that develop isolatedly. Computed tomography is the most useful tool in the evaluation of inflammatory processes of the paranasal sinuses. Computed tomography also plays a relevant role in the preoperative planning as well as in the postoperative follow-up, since it demonstrates exact anatomical details of normal structures with accuracy in the detection of variants. In the present pictorial essay, the authors describe the most common anatomical variants of the ethmoid labyrinth and their relationship with adjacent structures. Endoscopic sinonasal surgery has become increasingly less invasive, requiring more detailed anatomical imaging of this region. (author)

  11. Total variation superiorization schemes in proton computed tomography image reconstruction

    CERN Document Server

    Penfold, S N; Censor, Y; Rosenfeld, A B

    2010-01-01

    Purpose: Iterative projection reconstruction algorithms are currently the preferred reconstruction method in proton computed tomography (pCT). However, due to inconsistencies in the measured data arising from proton energy straggling and multiple Coulomb scattering, noise in the reconstructed image increases with successive iterations. In the current work, we investigated the use of total variation superiorization (TVS) schemes that can be applied as an algorithmic add-on to perturbation-resilient iterative projection algorithms for pCT image reconstruction. Methods: The block-iterative diagonally relaxed orthogonal projections (DROP) algorithm was used for reconstructing Geant4 Monte Carlo simulated pCT data sets. Two TVS schemes added on to DROP were investigated; the first carried out the superiorization steps once per cycle and the second once per block. Simplifications of these schemes, involving the elimination of the computationally expensive feasibility proximity checking step of the TVS framework, we...

  12. Pulmonary lymphomas: high-resolution computed tomography and anatomopathological correlation

    International Nuclear Information System (INIS)

    This paper describes the high-resolution computed tomography and anatomopathological findings of pulmonary lymphomas. We studied the chest high-resolution computed tomographs and histopathological data of 10 patients with biopsy-proven non-Hodgkin's or Hodgkin's disease. The most common radiologic findings in this series were areas of consolidation with air-bronchogram (n = 8). Others findings included multiple pulmonary nodules (n = 4), thickening of bronchovascular bundles (n =3) and foci of ground-glass attenuation (n =2). The present series results are consistent with the current available literature on radiographic appearance of the disease. The pathological correspondence of the areas of air space consolidation was alveolar filling by neoplastic cells, the thickening of bronchovascular bundles was secondary to lymphomatous cells infiltrates, and the areas of ground-glass attenuation corresponded to alveolar septal infiltration by these cells. (author)

  13. High-precision synthetic computed tomography of reconstructed porous media

    Science.gov (United States)

    Hilfer, R.; Zauner, Th.

    2011-12-01

    Multiscale simulation of transport in disordered and porous media requires microstructures covering several decades in length scale. X-ray and synchrotron computed tomography are presently unable to resolve more than one decade of geometric detail. Recent advances in pore scale modeling [Biswal, Held, Khanna, Wang, and Hilfer, Phys. Rev. E PLEEE81539-375510.1103/PhysRevE.80.041301 80, 041301 (2009)] provide strongly correlated microstructures with several decades in microstructural detail. A carefully calibrated microstructure model for Fontainebleau sandstone has been discretized into a suite of three-dimensional microstructures with resolutions from roughly 128 μm down to roughly 500 nm. At the highest resolution the three-dimensional image consists of 327683=35184372088832 discrete cubic volume elements with gray values between 0 and 216. To the best of our knowledge, this synthetic image is the largest computed tomogram of a porous medium available at present.

  14. X-ray machine vision and computed tomography

    International Nuclear Information System (INIS)

    This survey examines how 2-D x-ray machine vision and 3-D computed tomography will be used in industry in the 1988-1995 timeframe. Specific applications are described and rank-ordered in importance. The types of companies selling and using 2-D and 3-D systems are profiled, and markets are forecast for 1988 to 1995. It is known that many machine vision and automation companies are now considering entering this field. This report looks at the potential pitfalls and whether recent market problems similar to those recently experienced by the machine vision industry will likely occur in this field. FTS will publish approximately 100 other surveys in 1988 on emerging technology in the fields of AI, manufacturing, computers, sensors, photonics, energy, bioengineering, and materials

  15. Denoising Message Passing for X-ray Computed Tomography Reconstruction

    CERN Document Server

    Perelli, Alessandro; Can, Ali; Davies, Mike E

    2016-01-01

    X-ray Computed Tomography (CT) reconstruction from sparse number of views is becoming a powerful way to reduce either the radiation dose or the acquisition time in CT systems but still requires a huge computational time. This paper introduces an approximate Bayesian inference framework for CT reconstruction based on a family of denoising approximate message passing (DCT-AMP) algorithms able to improve both the convergence speed and the reconstruction quality. Approximate Message Passing for Compressed Sensing has been extensively analysed for random linear measurements but there are still not clear solutions on how AMP should be modified and how it performs with real world problems. In particular to overcome the convergence issues of DCT-AMP with structured measurement matrices, we propose a disjoint preconditioned version of the algorithm tailored for both the geometric system model and the noise model. In addition the Bayesian DCT-AMP formulation allows to measure how the current estimate is close to the pr...

  16. Simulation study of respiratory-induced errors in cardiac positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Heart disease is a leading killer in Canada and positron emission tomography (PET) provides clinicians with in vivo metabolic information for diagnosing heart disease. Transmission data are usually acquired with 68Ge, although the advent of PET/CT scanners has made computed tomography (CT) an alternative option. The fast data acquisition of CT compared to PET may cause potential misregistration problems, leading to inaccurate attenuation correction (AC). Using Monte Carlo simulations and an anthropomorphic dynamic computer phantom, this study determines the magnitude and location of respiratory-induced errors in radioactivity uptake measured in cardiac PET/CT. A homogeneous tracer distribution in the heart was considered. The AC was based on (1) a time-averaged attenuation map (2) CT maps from a single phase of the respiratory cycle, and (3) CT maps phase matched to the emission data. Circumferential profiles of the heart uptake were compared and differences of up to 24% were found between the single-phase CT-AC method and the true phantom values. Simulation results were supported by a PET/CT canine study which showed differences of up to 10% in the heart uptake in the lung-heart boundary region when comparing 68Ge- to CT-based AC with the CT map acquired at end inhalation

  17. Clinical utility of dental cone-beam computed tomography: current perspectives

    OpenAIRE

    Jaju PP; Jaju SP

    2014-01-01

    Prashant P Jaju,1 Sushma P Jaju21Oral Medicine and Radiology, 2Conservative Dentistry and Endodontics, Rishiraj College of Dental Sciences and Research Center, Bhopal, IndiaAbstract: Panoramic radiography and computed tomography were the pillars of maxillofacial diagnosis. With the advent of cone-beam computed tomography, dental practice has seen a paradigm shift. This review article highlights the potential applications of cone-beam computed tomography in the fields of dental implantology an...

  18. Correction for polychromatic aberration in computed tomography images

    International Nuclear Information System (INIS)

    A method and apparatus for correcting a computed tomography image for polychromatic aberration caused by the non-linear interaction (i.e. the energy dependent attenuation characteristics) of different body constituents, such as bone and soft tissue, with a polychromatic X-ray beam are described in detail. An initial image is conventionally computed from path measurements made as source and detector assembly scan a body section. In the improvement, each image element of the initial computed image representing attenuation is recorded in a store and is compared with two thresholds, one representing bone and the other soft tissue. Depending on the element value relative to the thresholds, a proportion of the respective constituent is allocated to that element location and corresponding bone and soft tissue projections are determined and stored. An error projection generator calculates projections of polychromatic aberration errors in the raw image data from recalled bone and tissue projections using a multidimensional polynomial function which approximates the non-linear interaction involved. After filtering, these are supplied to an image reconstruction computer to compute image element correction values which are subtracted from raw image element values to provide a corrected reconstructed image for display. (author)

  19. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    International Nuclear Information System (INIS)

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  20. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog [Department of Oral and Maxillofacial Radiology, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  1. Estimation of computed tomography dose index in cone beam computed tomography: MOSFET measurements and Monte Carlo simulations.

    Science.gov (United States)

    Kim, Sangroh; Yoshizumi, Terry; Toncheva, Greta; Yoo, Sua; Yin, Fang-Fang; Frush, Donald

    2010-05-01

    To address the lack of accurate dose estimation method in cone beam computed tomography (CBCT), we performed point dose metal oxide semiconductor field-effect transistor (MOSFET) measurements and Monte Carlo (MC) simulations. A Varian On-Board Imager (OBI) was employed to measure point doses in the polymethyl methacrylate (PMMA) CT phantoms with MOSFETs for standard and low dose modes. A MC model of the OBI x-ray tube was developed using BEAMnrc/EGSnrc MC system and validated by the half value layer, x-ray spectrum and lateral and depth dose profiles. We compared the weighted computed tomography dose index (CTDIw) between MOSFET measurements and MC simulations. The CTDIw was found to be 8.39 cGy for the head scan and 4.58 cGy for the body scan from the MOSFET measurements in standard dose mode, and 1.89 cGy for the head and 1.11 cGy for the body in low dose mode, respectively. The CTDIw from MC compared well to the MOSFET measurements within 5% differences. In conclusion, a MC model for Varian CBCT has been established and this approach may be easily extended from the CBCT geometry to multi-detector CT geometry. PMID:20386198

  2. Quantifying the debonding of inclusions through tomography and computational homology.

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Wei-Yang; Johnson, George C. (University of California, Berkeley, Berkeley, CA); Mota, Alejandro; Foulk, James W., III; Jin, Huiqing

    2010-09-01

    This report describes a Laboratory Directed Research and Development (LDRD) project to use of synchrotron-radiation computed tomography (SRCT) data to determine the conditions and mechanisms that lead to void nucleation in rolled alloys. The Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory (LBNL) has provided SRCT data of a few specimens of 7075-T7351 aluminum plate (widely used for aerospace applications) stretched to failure, loaded in directions perpendicular and parallel to the rolling direction. The resolution of SRCT data is 900nm, which allows elucidation of the mechanisms governing void growth and coalescence. This resolution is not fine enough, however, for nucleation. We propose the use statistics and image processing techniques to obtain sub-resolution scale information from these data, and thus determine where in the specimen and when during the loading program nucleation occurs and the mechanisms that lead to it. Quantitative analysis of the tomography data, however, leads to the conclusion that the reconstruction process compromises the information obtained from the scans. Alternate, more powerful reconstruction algorithms are needed to address this problem, but those fall beyond the scope of this project.

  3. Computed tomography image reconstruction from only two projections

    CERN Document Server

    Mohammad-Djafari, Ali

    2007-01-01

    English: This paper concerns the image reconstruction from a few projections in Computed Tomography (CT). The main objective of this paper is to show that the problem is so ill posed that no classical method, such as analytical methods based on inverse Radon transform, nor the algebraic methods such as Least squares (LS) or regularization theory can give satisfactory result. As an example, we consider in detail the case of image reconstruction from two horizontal and vertical projections. We then show how a particular composite Markov modeling and the Bayesian estimation framework can possibly propose satisfactory solutions to the problem. For demonstration and educational purpose a set of Matlab programs are given for a live presentation of the results. ----- French: Ce travail, \\`a but p\\'edagogique, pr\\'esente le probl\\`eme inverse de la reconstruction d'image en tomographie X lorsque le nombre des projections est tr\\`es limit\\'e. voir le texte en Anglais et en Fran\\c{c}ais.

  4. Mycosis fungoides: Positron emission tomography/computed tomography in staging and monitoring the effect of therapy

    International Nuclear Information System (INIS)

    A 58-year-old woman, diagnosed as a case of mycosis fungoides (MF), underwent [18F]-fluoro-D-glucose positron emission tomography/computed tomography (FDG PET/CT) examination. The study revealed intense FDG uptake in a large ulceroproliferative right thigh lesion, indurated plaques in the chest wall and left thigh, along with multiple sites of cutaneous involvement, axillary and inguinal lymphadenopathy. The patient underwent chemotherapy with CHOP regimen, radiotherapy for the right thigh lesion, along with topical corticosteroids and emollients for the disseminated cutaneous involvement. Repeat [18F]-FDG PET/CT study performed a year later, showed near complete disease regression specifically of the ulceroproliferative lesion and indurated cutaneous plaques, no change in lymphadenopathy, and a subtle diffuse progression of the remaining cutaneous lesions. A multidisciplinary approach to the diagnosis, staging and treatment of MF has long been suggested for optimizing outcomes from management of patients with this disease. This case highlights the potential role of incorporating PET/CT as a single modality imaging technique in the staging and assessment of response to therapy

  5. Fluoro-deoxy-glucose positron emission tomography/computed tomography in lymphoma: a pictorial essay

    International Nuclear Information System (INIS)

    F-18 fluoro-deoxy-glucose (FDG) positron emission tomography/computed tomography (PET/CT) has emerged as a powerful imaging modality in the field of oncology. F-18 FDG PET/CT is now an established tool in the management of lymphoma. This has been shown to be useful in staging, detection of bone marrow involvement (BMI), early response assessment and end of therapy response assessment in lymphoma. Interpretation of F-18 FDG PET/CT in lymphoma is carried out by various qualitative response assessment criteria. London criteria are used for interpretation of interim PET/CT and International Harmonization Project (IHP) criteria are used to interpret PET/CT done after the end of chemotherapy. Quantitative analysis is also found to be useful in assessment of response early after two cycles of chemotherapy in patients with diffuse large B cell lymphoma (DLBCL). This pictorial essay provides few images describing the FDG avidity of lymphoma, patterns of bone marrow uptake and their relevance in predicting BMI, role of staging PET/CT, quantitative analysis in response assessment, example images of response according to London criteria and IHP criteria. Few pitfalls in imaging of lymphoma with PET/CT are also discussed in the images legend. (author)

  6. Positron emission tomography/computer tomography in guidance of extrahepatic hepatocellular carcinoma metastasis management

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Hepatocellular carcinoma (HCC) is one of the most common primary cancers in the world. Surgery is the gold standard for treatment of patients with HCC. Recurrence and metastasis are the major obstacles to further improve the prognosis of HCC. Most recurrences are intrahepatic. However, 30% of the recurrences are extrahepatic. The role of resection in intrahepatic recurrences is widely accepted. The role of resection in extrahepatic HCC recurrence and metastasis is not well established. 18F fluorodeoxyglucose (18F-FDG) positron emission tomography/computer tomography (PET/CT) is useful in detecting distant metastasis from a variety of malignancies and shows superior accuracy to conventional imaging modalities in identification of intrahepatic and extrahepatic metastasis. We present one patient with one new isolated omental lymph node metastasis, who had a history of huge HCC resected six years ago. The metastatic focus was identified with 18 F-FDG PET/CT and resected. The follow-up revealed good prognosis with a long-term survival potential after resection of the omental lymphatic metastasis.

  7. Use of Positron Emission Tomography/Computed Tomography in Radiation Treatment Planning for Lung Cancer

    Directory of Open Access Journals (Sweden)

    Kezban Berberoğlu

    2016-06-01

    Full Text Available Radiotherapy (RT plays an important role in the treatment of lung cancer. Accurate diagnosis and staging are crucial in the delivery of RT with curative intent. Target miss can be prevented by accurate determination of tumor contours during RT planning. Currently, tumor contours are determined manually by computed tomography (CT during RT planning. This method leads to differences in delineation of tumor volume between users. Given the change in RT tools and methods due to rapidly developing technology, it is now more significant to accurately delineate the tumor tissue. F18 fluorodeoxyglucose positron emission tomography/CT (F18 FDG PET/CT has been established as an accurate method in correctly staging and detecting tumor dissemination in lung cancer. Since it provides both anatomic and biologic information, F18 FDG PET decreases interuser variability in tumor delineation. For instance, tumor volumes may be decreased as atelectasis and malignant tissue can be more accurately differentiated, as well as better evaluation of benign and malignant lymph nodes given the difference in FDG uptake. Using F18 FDG PET/CT, the radiation dose can be escalated without serious adverse effects in lung cancer. In this study, we evaluated the contribution of F18 FDG PET/CT for RT planning in lung cancer.

  8. Absorbed and effective dose from spiral and computed tomography for the dental implant planning

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Beong Hee; Han, Won Jeong; Kim, Eun Kyung [Dankook Univ. School of Dentistry, Seoul (Korea, Republic of)

    2001-09-15

    To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. For radiographic projection. TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophages. Effective dose was calculated, using the method suggested by Frederiksen at al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning.

  9. Absorbed and effective dose from spiral and computed tomography for the dental implant planning

    International Nuclear Information System (INIS)

    To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. For radiographic projection. TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophages. Effective dose was calculated, using the method suggested by Frederiksen at al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning

  10. Inflammatory disease of the brain diagnosed by computed tomography

    International Nuclear Information System (INIS)

    Inflammatory disease of the brain, particularly of pyogenic etiology, may be most accurately assessed by the use of computed tomography and contrast enhancement. Examples of cerebritis, evolving and mature intracerebral abcesses, and inflammatory extracerebral collections are presented and discussed, particularly with reference to differential diagnosis and the problem of infectious versus neoplastic etiology. Ancillary studies, particulary selective arteriography, are reviewed where appropriate. The residual changes of inflammatory disease of the brain after medical and/or surgical therapy are illustrated, and the value of serial examinations is emphasized. The rural indigent patient population (American Indian) served by the University of New Mexico Medical Center is a source of case material providing several examples of severe and untreated intracerebral infectious processes heretofore not described in the literature. (orig.)

  11. Basal ganglia calcification on computed tomography in systemic lupus erythematosus

    International Nuclear Information System (INIS)

    The development of basal ganglia calcification was studied in 85 patients with systemic lupus erythematosus (SLE) by computed tomography (CT). Bilateral calcification of the basal ganglia was found to occur in 5 patients (5.9 %) with SLE, but was not seen in patients with rheumatoid arthritis and progressive systemic sclerosis. All were female with a mean age of 42 years (range 29 - 49). The patients with calcification of the basal ganglia had neurological symptoms, such as psychiatric problems (3 cases), grand mal seizures (1 case), CSF abnormalities (2 cases), and EEG changes (4 cases). There were significantly higher incidences of alopecia, cutaneous vasculitis, leukopenia, and thrombocytopenia in the group with calcifications than those in the group with normal CT findings. Circulating immune complexes were detected and LE tests were positive in 2 patients. Endocrinological examination showed no abnormality in any. We suggest that basal ganglia calcification in SLE might be related to cerebral vasculitis. (author)

  12. Cysticercosis of the brain. The value of computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Almeida-Pinto, J.; Veiga-Pires, J.A.; Stocker, A.; Coelho, T.; Monteiro, L.

    Incidence and radiologic findings of neurocysticercosis were investigated in a series of 23 800 consecutive head examinations using computed tomography (CT). The condition was diagnosed in 168 case (0.7%). The parenchymatous form was the most common presentation (96.3%), while the meningeal form corresponded to only 11.9% of cases. These two forms coexisted in some cases. These findings reversed the knowledge on the condition based on conventional radiography. The different CT appearances in the brain are described and a new radiologic protocol for the CT evaluation of the condition is advocated, which includes a follow-up after a trial cure with Praziquantel in the presence of cysts not associated with suggestive brain calcifications. CT were more sensitive than conventional radiography in the differentiation between dead and living larvae, thus having an impact on the therapeutic management of the patients.

  13. Sacrococcygeal chordoma: Magnetic resonance imaging and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, D.I.; Scott, J.A.; Mankin, H.J.; Wismer, G.L.; Brady, T.J.

    1985-07-01

    Magnetic resonance imaging (MRI) was compared to computed tomography (CT) in four cases of sacrococcygeal chordoma. Both techniques yielded important anatomic information and represented important advances over early radiologic imaging methods. MRI provided superior contrast with surrounding soft tissues because of the prolonged T1 and T2 times of the tumors. The direct sagittal images obtained by MRI were valuable in determining the extent of lesions. Either MRI or direct CT coronal images were needed for the demonstration of tumor involving the sacral nerve roots. It was not possible to reliably distinguish between tumor adherent to bowel wall and bowel wall invasion by either technique. It is concluded that MRI is at least equal to CT for demonstration of these lesions and seems likely to become the imaging method of choice.

  14. CROSSED FUSED RENAL ECTOPIA MULTIDETECTOR COMPUTED TOMOGRAPHY STUDY

    Directory of Open Access Journals (Sweden)

    Sharma V

    2014-06-01

    Full Text Available Crossed renal ectopia is one of the rarest congenital malformations where a kidney is located on the side opposite to the side of its ureteral insertion into the urinary bladder and is generally fused with the normally located ipsilateral mate. Generally this anomaly remains as a silent clinical entity and is incidentally detected during evaluation for other conditions. We report here three such cases of crossed fused renal ectopia detected by multidetector row contrast enhanced computed tomography. Crossed fused renal ectopia of inferior type was observed in a male on the right side with the ureter of the ectopic left kidney crossing the midline. In two female patients, L-shaped or tandem kidney was noted, one on the right and another on the left side. Over all in two cases the left kidney was ectopic and in one the right kidney. No renal pathologies like urinary tract infection, nephrolithiasis or hematuria were found in our patients.

  15. Computed tomography of the sternum and its articulations

    International Nuclear Information System (INIS)

    The chest wall presents diagnostic difficulties for both the clinician and the radiologist. Because of normal variations in anatomy and ossification, analysis of the sternal region can be particularly confusing. We reviewed the normal computed tomographie (CT) appearance of the sternum in 354 patients. Important normal sternal variants included cortical insharpness along the posterior aspect of the manubrium, lateral surfaces of the body, and at the sternal fibrocartilaginous articulations; soft tissue prominence at the junction of the sternum and costochondral cartilage; and bony sclerosis at the transitions from manubrium to body and from body to xiphoid. In seven patients with clinically significant sternal abnormality, key CT features were abnormal soft tissue mass (7/7), destruction or irregularity of the cortical contour (7/7), and abnormal increased attenuation of bone (1/7). CT should be the radiologic study of choice in patients with suspected abnormality of the sternum and its articulations. (orig.)

  16. FDG positron emission computed tomography in a study of aphasia

    International Nuclear Information System (INIS)

    Positron emission computed tomography (PECT) using 18F-2-fluoro-2-deoxy-D-glucose (FDG) was used to investigate the correlations between clinical status, anatomy (as described by CT), and metabolism in five patients with stable aphasia resulting from ischemic cerebral infarction. Local cerebral metabolic activity was diminished in an area larger than the area of infarction demonstrated by CT. In one patient, FDG PECT revealed a metabolic lesion that probably caused the aphasic syndrome and was not apparent by CT. The data suggest that reliance on CT in delineating the extent of the brain lesion in aphasia or other neuropsychological defects can be misleading; FDG PECT may provide important additional information. Two patients with similar metabolic lesions had very different clinical syndromes, showing that even when currently available methods are combined, major gaps remain in clinicoanatomical correlations in aphasia

  17. Fossa navicularis magna detection on cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Syed, Ali Z. [Dept. of Oral and Maxillofacial Medicine and Diagnostic Sciences, School of Dental Medicine, Case Western Reserve University, Cleveland(United States); Mupparapu, Mel [Div. of Radiology, University of Pennsylvania School of Dental Medicine, Philadelphia (United States)

    2016-03-15

    Herein, we report and discuss the detection of fossa navicularis magna, a close radiographic anatomic variant of canalis basilaris medianus of the basiocciput, as an incidental finding in cone-beam computed tomography (CBCT) imaging. The CBCT data of the patients in question were referred for the evaluation of implant sites and to rule out pathology in the maxilla and mandible. CBCT analysis showed osseous, notch-like defects on the inferior aspect of the clivus in all four cases. The appearance of fossa navicularis magna varied among the cases. In some, it was completely within the basiocciput and mimicked a small rounded, corticated, lytic defect, whereas it appeared as a notch in others. Fossa navicularis magna is an anatomical variant that occurs on the inferior aspect of the clivus. The pertinent literature on the anatomical variations occurring in this region was reviewed.

  18. Application of cone beam computed tomography in facial imaging science

    Institute of Scientific and Technical Information of China (English)

    Zacharias Fourie; Janalt Damstra; Yijin Ren

    2012-01-01

    The use of three-dimensional (3D) methods for facial imaging has increased significantly over the past years.Traditional 2D imaging has gradually being replaced by 3D images in different disciplines,particularly in the fields of orthodontics,maxillofacial surgery,plastic and reconstructive surgery,neurosurgery and forensic sciences.In most cases,3D facial imaging overcomes the limitations of traditional 2D methods and provides the clinician with more accurate information regarding the soft-tissues and the underlying skeleton.The aim of this study was to review the types of imaging methods used for facial imaging.It is important to realize the difference between the types of 3D imaging methods as application and indications thereof may differ.Since 3D cone beam computed tomography (CBCT) imaging will play an increasingly importanl role in orthodontics and orthognathic surgery,special emphasis should be placed on discussing CBCT applications in facial evaluations.

  19. Recent Developments in Computed Tomography for Urolithiasis: Diagnosis and Characterization

    Directory of Open Access Journals (Sweden)

    P. D. Mc Laughlin

    2012-01-01

    Full Text Available Objective. To critically evaluate the current literature in an effort to establish the current role of radiologic imaging, advances in computed tomography (CT and standard film radiography in the diagnosis, and characterization of urinary tract calculi. Conclusion. CT has a valuable role when utilized prudently during surveillance of patients following endourological therapy. In this paper, we outline the basic principles relating to the effects of exposure to ionizing radiation as a result of CT scanning. We discuss the current developments in low-dose CT technology, which have resulted in significant reductions in CT radiation doses (to approximately one-third of what they were a decade ago while preserving image quality. Finally, we will discuss an important recent development now commercially available on the latest generation of CT scanners, namely, dual energy imaging, which is showing promise in urinary tract imaging as a means of characterizing the composition of urinary tract calculi.

  20. Cone Beam Computed Tomography Evaluation of Inverted Mesiodentes.

    Science.gov (United States)

    Al-Sehaibany, Fares S; Marzouk, Hazem M; Salama, Fouad S

    2016-01-01

    A mesiodens is the most common type of supernumerary teeth. The purpose of this report is to present a rare occurrence of non-syndromic impacted inverted mesiodentes in an 8.5-year-old boy who presented with a chief complaint of delayed eruption of his permanent maxillary left central incisor. Occlusal and panoramic radiographs, as well as cone beam computed tomography (CBCT) with a three-dimensional (3-D) reconstruction image, confirmed that one supernumerary tooth had perforated the nasal fossa floor and the other was in close approximation to the to the same site. Surgical removal of both mesiodentes was indicated. Radiographic evidence of complete healing was observed 12 months following surgical removal. The use of CBCT with a 3-D reconstruction image as a tool in diagnosis and evaluation of healing after surgical removal is recommended.

  1. Computed tomography dose optimisation in cystic fibrosis: A review.

    LENUS (Irish Health Repository)

    Ferris, Helena

    2016-04-28

    Cystic fibrosis (CF) is the most common autosomal recessive disease of the Caucasian population worldwide, with respiratory disease remaining the most relevant source of morbidity and mortality. Computed tomography (CT) is frequently used for monitoring disease complications and progression. Over the last fifteen years there has been a six-fold increase in the use of CT, which has lead to a growing concern in relation to cumulative radiation exposure. The challenge to the medical profession is to identify dose reduction strategies that meet acceptable image quality, but fulfil the requirements of a diagnostic quality CT. Dose-optimisation, particularly in CT, is essential as it reduces the chances of patients receiving cumulative radiation doses in excess of 100 mSv, a dose deemed significant by the United Nations Scientific Committee on the Effects of Atomic Radiation. This review article explores the current trends in imaging in CF with particular emphasis on new developments in dose optimisation.

  2. Experimental determination of the segregation process using computer tomography

    Directory of Open Access Journals (Sweden)

    Konstantin Beckmann

    2016-08-01

    Full Text Available Modelling methods such as DEM and CFD are increasingly used for developing high efficient combine cleaning systems. For this purpose it is necessary to verify the complex segregation and separation processes in the combine cleaning system. One way is to determine the segregation and separation function using 3D computer tomography (CT. This method makes it possible to visualize and analyse the movement behaviour of the components of the mixture during the segregation and separation process as well as the derivation of descriptive process parameters. A mechanically excited miniature test rig was designed and built at the company CLAAS Selbstfahrende Erntemaschinen GmbH to achieve this aim. The investigations were carried out at the Fraunhofer Institute for Integrated Circuits IIS. Through the evaluation of the recorded images the segregation process is described visually. A more detailed analysis enabled the development of segregation and separation function based on the different densities of grain and material other than grain.

  3. Experimental determination of the segregation process using computer tomography

    Directory of Open Access Journals (Sweden)

    Konstantin Beckmann

    2016-07-01

    Full Text Available Modelling methods such as DEM and CFD are increasingly used for developing high efficient combine cleaning systems. For this purpose it is necessary to verify the complex segregation and separation processes in the combine cleaning system. One way is to determine the segregation and separation function using 3D computer tomography (CT. This method makes it possible to visualize and analyse the movement behaviour of the components of the mixture during the segregation and separation process as well as the derivation of descriptive process parameters. A mechanically excited miniature test rig was designed and built at the company CLAAS Selbstfahrende Erntemaschinen GmbH to achieve this aim. The investigations were carried out at the Fraunhofer Institute for Integrated Circuits IIS. Through the evaluation of the recorded images the segregation process is described visually. A more detailed analysis enabled the development of segregation and separation function based on the different densities of grain and material other than grain.

  4. Software innovations in computed tomography for structural heart disease interventions.

    Science.gov (United States)

    Hell, Michaela; Marwan, Mohamed; Gaede, Luise; Achenbach, Stephan

    2016-05-17

    Computed tomography (CT) provides high, isotropic spatial resolution and has become firmly established in pre-procedural imaging for structural heart disease interventions. It allows determination of the exact dimensions of the target structure, provides information regarding the access route and permits identification of fluoroscopic projection angles to provide optimal visualisation for device placement. Several software solutions are available and have been systematically evaluated in the context of transcatheter aortic valve implantation (TAVI). The use of software products to perform automated measurements can be useful, especially when the experience and expertise regarding evaluation of CT in the context of structural heart disease are limited. In scientific studies, software has been demonstrated to provide accurate support for annulus sizing and prosthesis selection, to aid in reliably identifying patients in whom a transfemoral access may be problematic, and to suggest suitable angulations for fluoroscopic imaging to achieve an orthogonal view onto the aortic valve during implantation.

  5. Emission computer tomography on a Dodewaard mixed oxide fuel pin

    International Nuclear Information System (INIS)

    A nondestructive technique as well as a destructive PIE technique have been used to verify the results obtained with a newly 8-e computer tomography (GECT) system. Multi isotope Scanning (MIS), electron probe micro analysis (EPMA) and GECT were used on a mixed oxide (MOX) fuel rod from the Dodewaard reactor with an average burnup of 24 MWd/kg fuel. GECT shows migration of Cs to the periphery of fuel pellets and to radial cracks and pores in the fuel, whereas MIS shows Cs migration to pellet interfaces. The EPMA technique appeared not to be useful to show migration of Cs but, it shows the distribution of fission products from Pu. EPMA clearly shows the distribution of fission products from Pu, but did not reveal the Cs-migration. (orig./HP)

  6. Lung cancer screening: Computed tomography or chest radiographs?

    Institute of Scientific and Technical Information of China (English)

    Edwin; JR; van; Beek; Saeed; Mirsadraee; John; T; Murchison

    2015-01-01

    Worldwide, lung cancer is the leading cause of mortalitydue to malignancy. The vast majority of cases of lung cancer are smoking related and the most effective way of reducing lung cancer incidence and mortality is by smoking cessation. In the Western world, smoking cessation policies have met with limited success. The other major means of reducing lung cancer deaths is to diagnose cases at an earlier more treatable stage employing screening programmes using chest radiographs or low dose computed tomography. In many countries smoking is still on the increase, and the sheer scale of the problem limits the affordability of such screening programmes. This short review article will evaluate the current evidence and potential areas of research which may benefit policy making across the world.

  7. Density gradients in ceramic pellets measured by computed tomography

    International Nuclear Information System (INIS)

    Density gradients are of fundamental importance in ceramic processing and computed tomography (CT) can provide accurate measurements of density profiles in sintered and unsintered ceramic parts. As a demonstration of this potential, the density gradients in an unsintered pellet pressed from an alumina powder were measured by CT scanning. To detect such small density gradients, the CT images must have good density resolution and be free from beam-hardening effects. This was achieved by measuring high-contrast (low-noise) images with the use of an Ir-192 isotopic source. A beam-hardening correction was applied. The resulting images are discussed relative to the transmission of forces through the powder mass during the pelletizing process

  8. Temporal bone trauma and complications: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Ana Maria Doffemond; Gaiotti, Juliana Oggioni; Couto, Caroline Laurita Batista; Gomes, Natalia Delage; Diniz, Renata Lopes Furletti Caldeira; Motta, Emilia Guerra Pinto Coelho, E-mail: anadoffemond@yahoo.com.br [Hospital Mater Dei, Belo Horizonte, MG (Brazil). Unit of Radiology and Imaging Diagnosis

    2013-03-15

    Most temporal bone fractures result from high-energy blunt head trauma, and are frequently related to other skull fractures or to polytrauma. Fractures and displacements of ossicular chain in the middle ear represent some of the main complications of temporal bone injury, and hence they will be more deeply approached in the present article. Other types of injuries include labyrinthine fractures, dural fistula, facial nerve paralysis and extension into the carotid canal. Computed tomography plays a fundamental role in the initial evaluation of polytrauma patients, as it can help to identify important structural injuries that may lead to severe complications such as sensorineural hearing loss, conductive hearing loss, dizziness and balance dysfunction, perilymphatic fistulas, facial nerve paralysis, vascular injury and others. (author)

  9. Improved proton computed tomography by dual modality image reconstruction

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Bassler, Niels; Petersen, Jørgen B.B.;

    2014-01-01

    Purpose: Proton computed tomography (CT) is a promising image modality for improving the stopping power estimates and dose calculations for particle therapy. However, the finite range of about 33 cm of water of most commercial proton therapy systems limits the sites that can be scanned from a full...... power. For the limited angle cases the maximal RMS error was 0.18, an almost five-fold improvement over the cone beam CT estimate. Conclusions: Dual modality reconstruction yields the high spatial resolution of cone beam x-ray CT while maintaining the improved stopping power estimation of proton CT....... In the case of limited angles, the use of prior image proton CT greatly improves the resolution and stopping power estimate, but does not fully achieve the quality of a 360◦ proton CT scan. © 2014 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4864239]...

  10. Dimensional measurement of micro-moulded parts by computed tomography

    DEFF Research Database (Denmark)

    Ontiveros, S.; Yagüe-Fabra, J.A.; Jiménez, R.;

    2012-01-01

    Computed tomography (CT) is progressively assuming an important role in metrology applications and great efforts are being made in order to turn it into a reliable and standardized measuring technology. CT is typically used for non-destructive tests, but it is currently becoming very popular for......-injection moulded components, selected from actual industrial productions, using CT metrological tools. For this purpose, several parts have been measured with two different CT machines, and the results have been compared with the measurements obtained by other measuring systems. The experimental work carried out...... and the analysis of the results provide valuable conclusions about the advantages and drawbacks of using CT metrology in comparison with other measuring systems when these techniques are employed for the quality control of micro-moulded parts....

  11. Criteria for diagnosing distal radioulnar joint subluxation by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Ryogo [Department of Orthopedic Surgery, Branch Hospital of Nagoya University, School of Medicine, 1-1-20 Daikominami, Higashiku, Nagoya 461 (Japan); Horii, Emiko [Department of Orthopedic Surgery, Branch Hospital of Nagoya University, School of Medicine, 1-1-20 Daikominami, Higashiku, Nagoya 461 (Japan); Imaeda, Toshihiko [Department of Orthopedic Surgery, Branch Hospital of Nagoya University, School of Medicine, 1-1-20 Daikominami, Higashiku, Nagoya 461 (Japan); Nakao, Etsuhiro [Department of Orthopedic Surgery, Branch Hospital of Nagoya University, School of Medicine, 1-1-20 Daikominami, Higashiku, Nagoya 461 (Japan)

    1996-10-01

    Bilateral wrist computed tomography (CT) was performed in 30 patients with suspected unilateral distal radioulnar joint (DRUJ) subluxation to evaluate dynamic DRUJ CT scanning with a straight elbow. Five CT criteria for diagnosing dorsovolar subluxation were examined. Maximum active supination and pronation on a conventional scanning table yielded satisfactory rotation (mean{+-}SD, 119 {+-}29 ) at the DRUJ, thus permitting a dynamic diagnosis of DRUJ subluxation. The radioulnar line method and the congruity method frequently yielded false positive results compared with bilateral diagnosis and were unreliable. Modifications of these two methods achieved sensitivity and specificity comparable to the epicenter method. We recommend the modified radioulnar line method for diagnosing dorsovolar subluxation using unilateral CT because of its excellent sensitivity and specificity combined with ease of technique. (orig.). With 4 figs., 2 tabs.

  12. Thermoluminescent dosimetry in computed tomography for pediatric patients

    International Nuclear Information System (INIS)

    Computed tomography (CT) in conjunction with interventional radiology, is considered as high-dose radiological procedure, so the optimization of the dose is necessary. Exposure to ionizing radiation in pediatric CT is of particular interest because the children are up to 10 times more sensitive to radiation than adults, the late somatic and genetic effects of radiation. The exposure and risk associated with ionizing radiation in CT is best characterized by the absorbed dose to each organ. Thermoluminescent dosimeters of LiF: Mg, Ti are best suited for this purpose due to its characteristics such as high sensitivity, small size and its equivalence with the tissue. The results of dose measurements -in vivo- to the three types of CT studies (skull, thorax and abdomen) are presented. These results indicate that lower doses were obtained in skull study, while the highest was one of abdomen. (Author)

  13. Survey of patient dose in computed tomography in Syria 2009.

    Science.gov (United States)

    Kharita, M H; Khazzam, S

    2010-09-01

    The radiation doses to patient in computed tomography (CT) in Syria have been investigated and compared with similar studies in different countries. This work surveyed 30 CT scanners from six different manufacturers distributed all over Syria. Some of the results in this paper were part of a project launched by the International Atomic Energy Agency in different regions of the world covering Asia, Africa and Eastern Europe. The dose quantities covered are CT dose index (CTDI(w)), dose-length product (DLP), effective dose (E) and collective dose. It was found that most CTDI(w) and DLP values were similar to the European reference levels and in line with the results of similar surveys in the world. The results were in good agreement with the UNSCEAR Report 2007. This study concluded a recommendation for national diagnostic reference level for the most common CT protocols in Syria. The results can be used as a base for future optimisation studies in the country.

  14. Real time evaluation of overranging in helical computed tomography

    CERN Document Server

    Trevisan, Diego; Ravanelli, Daniele; Valentini, Aldo

    2014-01-01

    Overranging or overscanning increases the dose delivered to patients undergoing helical Computed Tomography examinations. In order to reduce it, nowadays most of the multidetector tomographs close the X-ray beam aperture at the scan extremes. This technical innovation, usually referred to as dynamic or adaptive collimation, also influences the overranging assessment methods. In particular, the film free approach proposed in previous studies is not suitable for these modern tomographs. The present study aims to introduce a new method of estimating overranging with real time dosimetry, even suitable for tomographs equipped with adaptive collimation. The approach proposed is very easy to implement and time saving because only a pencil chamber is required. It is also equivalent in precision and in accuracy to the film based one, considered an absolute benchmark.

  15. Unusual computed tomography findings and complications in acute appendicitis

    International Nuclear Information System (INIS)

    The objective of this article is to describe and illustrate unusual computed tomography (CT) findings in patients with acute appendicitis. We reviewed the charts of 200 patients with clinical suspicion of acute appendicitis who were submitted to abdominal CT before surgery. Patients with unusual presentation or complications were selected for illustrating the main CT findings. Unusual complications of acute appendicitis were related to anomalous position of the appendix, contiguity to intraperitoneal organs such as the liver, gall bladder, annexes and the bladder and continuous use of anti inflammatory or antibiotics during the diagnostic process. We concluded that CT is a useful diagnostic tool in patients with complicated or unusual presentation acute appendicitis. The first step towards diagnosis in these cases i to have in mind the hypothesis of appendicitis in patients with acute abdominal pain. (author)

  16. Meningitis tuberculosa: Clinical findings and results of cranial computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Trautmann, M.; Loddenkemper, R.; Hoffmann, H.G.

    1982-10-01

    Guided by 9 own observations between 1977 and 1981, new diagnostic facilities in tuberculous meningitis are discussed. For differentiation from viral meningitis, measurement of CSF lactic acid concentration in addition to that of CSF glucose has proved to be of value in recent years. In accordance with the literature, two cases of this series which were examined for CSF lactic acid concentration showed markedly elevated levels of 8,4 rsp. 10,4 mmol/l. In contrast to this, in viral meningitis usually values of less than 3.5 mmol/l are found. Additionally, the presence of hypochlor- and hyponatremia, which could be demonstrated in 6 of our 9 patients, may raise the suspicion of tuberculous etiology. In the series presented, cranial computed tomography was of greatest diagnostic value, enabling the diagnosis of hydrocephalus internus in 5, and basal arachnoiditis in 2 cases.

  17. Computed tomography in the evaluation of the suspected carcinomatous prostate

    International Nuclear Information System (INIS)

    Twenty-six patients with physical findings suspicious for prostatic cancer were examined by contrast-enhanced computed tomography (CT) of the prostate region prior to prostatic biopsy or resection. Twelve had benign hypertrophy and/or prostatitis and fourteen had adenocarcinoma. Prostatic contour, density, seminal vesicle 'angle,' extraprostatic soft tissue 'mass,' and the pelvic fat planes were evaluated. A nodular prostatic contour was found only in patients with adenocarcinoma of the prostate, indicating a role for CT in the diagnosis of this disease. Two patients with benign prostatic disease had extraprostatic soft tissue 'masses' identical to those seen in six patients with adenocarcinoma of the prostate, suggesting limited usefulness of CT in staging patients with known tumor. (orig.)

  18. Use and impact of positron computed tomography scanning in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Mazziotta, J.C.; Engel, J. Jr.

    1984-01-01

    Through the effective combination of instrumentation, tracer kinetic principles, and radiopharmaceuticals, positron computed tomography (PET) allows for the analytic, noninvasive measurement of local tissue physiology in humans. A large number of studies have already been performed in patients with epilepsy using 18F-fluorodeoxyglucose (FDG) to measure local cerebral glucose utilization. In patients with complex partial epilepsy who are candidates for surgery, hypometabolic zones have been seen consistently (70%) in the interictal state. The complex anatomical and pathophysiological investigation of these hypometabolic zones is discussed. Ictal studies of patients with partial seizures have demonstrated a much more variable metabolic pattern which usually consists of hypermetabolism relative to baseline or interictal studies. Generalized epilepsy produced by electroconvulsive shock and petit mal epilepsy have been studied using FDG to estimate glucose metabolism.

  19. Data fusion in neutron and X-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Schrapp, Michael J. [Siemens AG, Corporate Technology, Otto-Hahn-Ring 6, 81739 Munich (Germany); Physik Department E21, Technische Universität München, James-Franck-Strasse 1, 85747 Garching (Germany); Goldammer, Matthias [Siemens AG, Corporate Technology, Otto-Hahn-Ring 6, 81739 Munich (Germany); Schulz, Michael [Physik Department E21, Technische Universität München, James-Franck-Strasse 1, 85747 Garching (Germany); Heinz Maier-Leibnitz Zentrum (MLZ), Technische Universität München, Lichtenbergstrasse 1, 85747 Garching (Germany); Issani, Siraj; Bhamidipati, Suryanarayana [Siemens AG, Corporate Technology, Bangalore (India); Böni, Peter [Physik Department E21, Technische Universität München, James-Franck-Strasse 1, 85747 Garching (Germany)

    2014-10-28

    We present a fusion methodology between neutron and X-ray computed tomography (CT). On the one hand, the inspection by X-ray CT of a wide class of multimaterials in non-destructive testing applications suffers from limited information of object features. On the other hand, neutron imaging can provide complementary data in such a way that the combination of both data sets fully characterizes the object. In this contribution, a novel data fusion procedure, called Fusion Regularized Simultaneous Algebraic Reconstruction Technique, is developed where the X-ray reconstruction is modified to fulfill the available data from the imaging with neutrons. The experiments, which were obtained from an aluminum profile containing a steel screw, and attached carbon fiber plates demonstrate that the image quality in CT can be significantly improved when the proposed fusion method is used.

  20. Data fusion in neutron and X-ray computed tomography

    International Nuclear Information System (INIS)

    We present a fusion methodology between neutron and X-ray computed tomography (CT). On the one hand, the inspection by X-ray CT of a wide class of multimaterials in non-destructive testing applications suffers from limited information of object features. On the other hand, neutron imaging can provide complementary data in such a way that the combination of both data sets fully characterizes the object. In this contribution, a novel data fusion procedure, called Fusion Regularized Simultaneous Algebraic Reconstruction Technique, is developed where the X-ray reconstruction is modified to fulfill the available data from the imaging with neutrons. The experiments, which were obtained from an aluminum profile containing a steel screw, and attached carbon fiber plates demonstrate that the image quality in CT can be significantly improved when the proposed fusion method is used.

  1. Lipoid pneumonia: computed tomography findings - a case report

    International Nuclear Information System (INIS)

    The authors report a case of lipoid pneumonia in an 80 year old man with chronic constipation in regular use of mineral oil as a laxative. According to his family, he experienced coughing episodes when he took his medication. He also presented dyspnoea at rest and diminished consciousness levels. Chest radiographs showed a consolidation area in the posterior segment of right upper lobe, which did not change on successive exams. High resolution computed tomography demonstrated low-density consolidation with negative Hounsfield units (-29 to -83 UH) and ground-glass opacities in the right upper lobe and inferior lobes. These opacities predominated in the posterior regions of the lungs. The diagnosis was confirmed by the presence of oil material on bronchoalveolar washing. The patient was advised to discontinue the ingestion of mineral oil and did not return for follow-up. (author)

  2. Systematic Errors in Dimensional X-ray Computed Tomography

    DEFF Research Database (Denmark)

    of the measurement. As a consequence, there is a high risk that on the basis of defective measurement results, a manufactured product is wrongly rejected in conformance testing. According to guidelines and standards, systematic error influences on a final measurand must be avoided or at least known so......A result of a measurement is usually affected by a measurement error which cannot be avoided in practice. Particularly in production metrology, systematic errors from, e.g, temperature influences, drift effects, etc., may lead to high measurement deviation in respect to the true value...... that it is possible to compensate them. In dimensional X-ray computed tomography (CT), many physical quantities influence the final result. However, it is important to know which factors in CT measurements potentially lead to systematic errors. In this talk, typical error sources in dimensional X-ray CT are discussed...

  3. Computed tomography evaluation of pulmonary alterations after radiotherapy

    International Nuclear Information System (INIS)

    A retrospective study of 15 patients with primary tumors, 13 of the lung and 2 breast cancers, treated in the Hospital Santa Cruz/Beneficiencia Portuguesa de Niteroi, RJ, in the period comprised from February 1991 to October 1996, was done. The pulmonary radiotherapy effects were observed in two clinical presentations - acute (radiation pneumonitis) and chronic (radiation fibrosis) -, both depending upon the radiotherapy doses, the radiation area, the individual susceptibility and the previous chemotherapy. Signs of pulmonary fibrosis were found in 73.3% of the patients, pneumonitis in 20.0% and absence of changes after radiation in 6.6%. Computed tomography was an excellent noninvasive diagnostic method in demonstrating radiotherapy-induced pulmonary changes, more evident in high-resolution technique scans. (author)

  4. Glasses for 3D ultrasound computer tomography: phase compensation

    Science.gov (United States)

    Zapf, M.; Hopp, T.; Ruiter, N. V.

    2016-03-01

    Ultrasound Computer Tomography (USCT), developed at KIT, is a promising new imaging system for breast cancer diagnosis, and was successfully tested in a pilot study. The 3D USCT II prototype consists of several hundreds of ultrasound (US) transducers on a semi-ellipsoidal aperture. Spherical waves are sequentially emitted by individual transducers and received in parallel by many transducers. Reflectivity volumes are reconstructed by synthetic aperture focusing (SAFT). However, straight forward SAFT imaging leads to blurred images due to system imperfections. We present an extension of a previously proposed approach to enhance the images. This approach includes additional a priori information and system characteristics. Now spatial phase compensation was included. The approach was evaluated with a simulation and clinical data sets. An increase in the image quality was observed and quantitatively measured by SNR and other metrics.

  5. Correlative neuroanatomy of computed tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Since the development of computed tomography (CT) more than a decade ago, still another form of imaging has become available that provides displays of normal and abnormal human structures. Magnetic resonance imaging is given complete coverage in this book. It describes both CT and MR anatomy that explains basic principles and the current status of imaging the brain and spine. The author uses three-dimensional concepts to provide the reader with a simple means to compare the main structures of the brain, skull and spine. Combining normal, gross neuroanatomic illustrations with CT and MR images of normal and abnormal conditions, the book provides diagnostic guidance. Drawings, photographs and radiologic images are used to help

  6. Post-chymopapain (chemonucleolysis) - clinical and computed tomography correlation

    Energy Technology Data Exchange (ETDEWEB)

    Mall, J.C.; Kaiser, J.C.

    1984-11-01

    Chymopapain was first used for treatment of lumbar disc herniation in 1964 and has been used extensively in Canada and Europe for the last decade, but was recently released for general use in the United States. The enzyme is thought to cause decrease in intradiscal pressure and in disc volume; however, little in vivo evidence exists to support this concept. High resolution computed tomography (CT) scans were performed for diagnosis and at a variable period following chemonucleolysis on 17 randomly selected patients. The results of the study were: (1) disc space narrowing occurred almost invariably; (2) retraction of the prolapsed or extruded disc occurred in many patients; (3) clinical improvement was closely related to retraction of the prolapsed or extruded disc; (4) the best clinical results were obtained in patients who were injected at a single level with a clearly demonstrable disc prolapse or herniation.

  7. Breast computed tomography with the PICASSO detector: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Rigon, Luigi, E-mail: luigi.rigon@ts.infn.i [INFN, Sezione di Trieste, Via Valerio 2, 34127 Trieste (Italy); Tapete, Federica [Azienda Ospedaliero-Universitaria ' Ospedali Riuniti' , 34142 Trieste (Italy); Dreossi, Diego [INFN, Sezione di Trieste, Via Valerio 2, 34127 Trieste (Italy); Sincrotrone Trieste SCpA, S.S. 14 km 163.5, 34012 Basovizza (TS) (Italy); Arfelli, Fulvia [INFN, Sezione di Trieste, Via Valerio 2, 34127 Trieste (Italy); Physics Department, University of Trieste, Via Valerio 2, 34127 Trieste (Italy); Bergamaschi, Anna [Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Chen, Rong-Chang [INFN, Sezione di Trieste, Via Valerio 2, 34127 Trieste (Italy); Physics Department, University of Trieste, Via Valerio 2, 34127 Trieste (Italy); Shanghai Institute of Applied Physics, Chinese Academy of Sciences, 201204 Shanghai (China); Longo, Renata [INFN, Sezione di Trieste, Via Valerio 2, 34127 Trieste (Italy); Physics Department, University of Trieste, Via Valerio 2, 34127 Trieste (Italy); Menk, Ralf-Hendrik [INFN, Sezione di Trieste, Via Valerio 2, 34127 Trieste (Italy); Sincrotrone Trieste SCpA, S.S. 14 km 163.5, 34012 Basovizza (TS) (Italy); Schmitt, Bernd [Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Vallazza, Erik [INFN, Sezione di Trieste, Via Valerio 2, 34127 Trieste (Italy); Castelli, Edoardo [INFN, Sezione di Trieste, Via Valerio 2, 34127 Trieste (Italy); Physics Department, University of Trieste, Via Valerio 2, 34127 Trieste (Italy)

    2011-02-01

    The SYRMEP (Synchrotron Radiation for Medical Physics) collaboration has performed, for the first time in the world, a clinical program of mammography with synchrotron radiation. This program provided excellent results, although utilizing a commercial screen-film system as a detector. The PICASSO (Phase Imaging for Clinical Application with Silicon detector and Synchrotron radiation) project has developed a detector prototype capable of fully exploiting the peculiar characteristics of the synchrotron source, utilizing silicon microstrip sensors illuminated in the edge-on geometry and operated in single-photon counting. In this paper the potential of the PICASSO detector in breast computed tomography was evaluated by means of custom phantoms. Very encouraging results have been obtained with severe dose constrains as far as both spatial and contrast resolution are concerned. Moreover, the capability of detecting phase contrast effects was demonstrated, albeit with a higher delivered dose.

  8. Degeneration in dysplastic hips. A computer tomography study

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Rømer, Lone; Søballe, Kjeld

    2005-01-01

    BACKGROUND: Hip dysplasia is considered pre-osteoarthritic, causing degeneration in young individuals. OBJECTIVE: To determine the pattern of degenerative change in moderate to severely dysplastic hips in young patients. DESIGN AND PATIENTS: One hundred and ninety-three consecutively......-referred younger patients with hip pain believed to be caused by hip dysplasia constituted the study cohort. The average age was 35.5 years (range, 15-61 years). They were examined by close-cut transverse pelvic and knee computed tomography and antero-posterior radiographs (CT). We identified 197 hips...... with moderate to severe dysplasia, and 78 hips with normal morphology in the study cohort, whilst 111 hip joints were borderline dysplastic according to preset definitions. Comparative analyses of anatomy and distribution of degeneration between dysplastic and normal hips in the study cohort were performed...

  9. Correlation modeling for compression of computed tomography images.

    Science.gov (United States)

    Munoz-Gomez, Juan; Bartrina-Rapesta, Joan; Marcellin, Michael W; Serra-Sagristà, Joan

    2013-09-01

    Computed tomography (CT) is a noninvasive medical test obtained via a series of X-ray exposures resulting in 3-D images that aid medical diagnosis. Previous approaches for coding such 3-D images propose to employ multicomponent transforms to exploit correlation among CT slices, but these approaches do not always improve coding performance with respect to a simpler slice-by-slice coding approach. In this paper, we propose a novel analysis which accurately predicts when the use of a multicomponent transform is profitable. This analysis models the correlation coefficient r based on image acquisition parameters readily available at acquisition time. Extensive experimental results from multiple image sensors suggest that multicomponent transforms are appropriate for images with correlation coefficient r in excess of 0.87. PMID:25055372

  10. Basal ganglia calcification on computed tomography in systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, Shohei; Tani, Kenji; Ishigatsubo, Yoshiaki and others

    1988-09-01

    The development of basal ganglia calcification was studied in 85 patients with systemic lupus erythematosus (SLE) by computed tomography (CT). Bilateral calcification of the basal ganglia was found to occur in 5 patients (5.9 %) with SLE, but was not seen in patients with rheumatoid arthritis and progressive systemic sclerosis. All were female with a mean age of 42 years (range 29 - 49). The patients with calcification of the basal ganglia had neurological symptoms, such as psychiatric problems (3 cases), grand mal seizures (1 case), CSF abnormalities (2 cases), and EEG changes (4 cases). There were significantly higher incidences of alopecia, cutaneous vasculitis, leukopenia, and thrombocytopenia in the group with calcifications than those in the group with normal CT findings. Circulating immune complexes were detected and LE tests were positive in 2 patients. Endocrinological examination showed no abnormality in any. We suggest that basal ganglia calcification in SLE might be related to cerebral vasculitis.

  11. Importance of computer tomography for diagnosis of pulmonary emphysema

    International Nuclear Information System (INIS)

    The advent of diagnostic imaging, such as computed tomography (CT), has allowed the detection of an enlarged intralobular space and its localization in pulmonary emphysema (PE). This review describes the usefulness and limitations of CT in the clinical diagnosis of PE, focusing on the correlation between PE and both pulmonary function and biochemical markers of EP lesions. There are two CT methods for detecting PE lesions; one is the visualization method for PE lesions using high-resolution CT, and the other is the quantitative method of PE using pulmonary density. Pulmonary function is correlated with both CT and pathologically proven PE lesions. Finally, the importance of integrated evaluation, including conventional CT modality for morphological measurement of PE, pulmonary function test, and biochemical approaches, is mentioned to diagnose PE early. (N.K.) 55 refs

  12. Cholesteatomas of the temporal bone: role of computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, D.W.; Voorhees, R.L.; Lufkin, R.B.; Canalis, R.

    1983-09-01

    Computed tomography (CT) of the temporal bone was performed in 64 patients thought to have a cholesteatoma of the middle ear. Twenty had not had surgery before, while 44 had been operated on; special consideration was given to 21 patients who were scanned immediately before a second operation and had confirmation of the CT findings. Inflammatory disease without cholesteatoma was characterized by absence of erosion of the otic capsule or ossicular chain. Sharply circumscribed cholesteatomas were easily diagnosed by CT. When they were combined with scarring, granulation tissue, or postsurgical changes, the resulting soft-tissue masses were indistinguishable, although cholesteatoma may be suspected if there is evidence of progressive bone erosion about the middle ear. CT can play a major role in postoperative follow-up by confirming that the ear is normal and demonstrating displacement of ossicular grafts or prostheses.

  13. Quality Criteria Implementation for Brain Computed Tomography Examinations

    Energy Technology Data Exchange (ETDEWEB)

    Calzado, A.; Rodriguez, R.; Munoz, A

    1998-07-01

    The main aim of this study was to implement the quality criteria proposed by the European Commission for brain computed tomography (CT) examinations. The proposed criteria were evaluated for 102 brain CT examinations, with a special emphasis on the diagnostic and radiation dose requirements. The examinations were selected at random from brain examinations performed over a period of a month at eight scanners of the CT Pace range. Achievement of image criteria was evaluated by two independent observers. The most important preliminary findings concerning image criteria fulfilment or lack of it and disagreements between observers are presented and discussed. The mean values of the proposed dosimetric quantities are compared to the reference values. The examinations performed with and without injection of a contrast agent are also analysed in relation to dosimetric quantities and criteria fulfilment. (author)

  14. Pulmonary blood flow distribution measured by radionuclide computed tomography

    International Nuclear Information System (INIS)

    Distributions of pulmonary blood flow per unit lung volume were measured in sitting patients with a radionuclide computed tomography (RCT) by intravenously administered Tc-99m macroaggregates of human serum albumin (MAA). Four different types of distribution were distinguished, among which a group referred as type 2 had a three zonal blood flow distribution as previously reported (West and co-workers, 1964). The pulmonary arterial pressure (Pa) and the venous pressure (Pv) were determined in this group of distribution. These values showed satifactory agreements with the pulmonary artery pressure (Par) and the capillary wedged pressure (Pcw) measured by Swan-Ganz catheter in eighteen supine patients. Those good correlations enable to establish a noninvasive methodology for measurement of pulmonary vascular pressures

  15. Diagnostic value of computer tomography in chronic pancreatitis

    International Nuclear Information System (INIS)

    During a 3-year-period 39 patients with chronic pancreatitis were subjected to roentgen examinations and exocrine pancreatic function tests (EPFT). Computer tomography (CT) was carried out in 36 of these, and revealed pancreatic disease in 29, while characteristic findings of chronic pancreatitis were demonstrated in 24 patients. CT was particularly valuable in diagnosing intra- and extrapancreatic pseudocysts and pancreatic abscesses complicating chronic pancreatitis. At endoscopic retrograde pancreatography (ERP) pathologic alterations were demonstrated in 23 of 24 patients, and was diagnostic for chronic pancreatitis in 20 patients. The cannulation failed in 7 patients. The results indicate that ERP cannot be replaced by CT. ERP is still needed for detailed demonstration of the pancreatic duct system, especially preoperatively. Conventional films of the abdomen, EPFT and angiography were the least sensitive tests. (Auth.)

  16. Gamma-ray computed tomography to characterize soil surface sealing

    Energy Technology Data Exchange (ETDEWEB)

    Pires, L.F.Luiz F. E-mail: lfpires@cena.usp.br; Macedo, Jose R. de; Souza, Manoel D. de; Bacchi, Osny O.S.; Reichardt, Klaus

    2002-09-01

    The application of sewage sludge as a fertilizer on soils may cause compacted surface layers (surface sealing), which can promote changes on soil physical properties. The objective of this work was to study the use of gamma-ray computed tomography, as a diagnostic tool for the evaluation of this sealing process through the measurement of soil bulk density distribution of the soil surface layer of samples subjected to sewage sludge application. Tomographic images were taken with a first generation tomograph with a resolution of 1 mm. The image analysis opened the possibility to obtain soil bulk density profiles and average soil bulk densities of the surface layer and to detect the presence of soil surface sealing. The sealing crust thickness was estimated to be in the range of 2-4 mm.

  17. Evaluation of solitary pulmonary nodule detected during computed tomography examination

    International Nuclear Information System (INIS)

    The solitary pulmonary nodule (SPN) has always been a diagnostic challenge for the radiologists. Currently, with increased utilization of computed tomography (CT) greater number of nodules is being discovered, with numerous indeterminate lesions, which frequently cannot be immediately classified into benign or malignant category. In this article we review the imaging features of benign and malignant round opacities; we demonstrate currently used standards and also more advanced techniques that are helpful in evaluating SPNs such as contrast-enhanced CT, PET/CT imaging and also pathologic sampling with biopsy or surgical resection. We also summarize the methods of evaluating and managing SPNs based on the latest guidelines from the Fleischner Society and American College of Chest Physicians

  18. Computed tomography in bronchogenic carcinoma- a pictorial essay

    International Nuclear Information System (INIS)

    Bronchogenic carcinoma is an extremely common and aggressive tumor, being the commonest cancer in men and the fourth commonest cancer in men and the fourth commonest cancer in women, ranking after breast, colon and skin cancers. The extent of the tumor has to be known accurately, as the treatment options change, based on the staging of the tumor. An advanced tumor cannot be resected and has to be treated by radiotherapy and/or chemotherapy. Computed Tomography (CT) is of great value in staging bronchogenic carcinomas and therefore helps in deciding the further management of the patient. In this pictorial essay, we illustrate the broad spectrum of abnormalities that can be shown by CT in bronchogenic carcinoma. (author). 21 refs., 21 figs

  19. Common findings and pseudolesions at computed tomography colonography: pictorial essay

    International Nuclear Information System (INIS)

    Computed tomography colonography is a minimally invasive method for screening for polyps and colorectal cancer, with extremely unusual complications, increasingly used in the clinical practice. In the last decade, developments in bowel preparation, imaging, and in the training of investigators have determined a significant increase in the method sensitivity. Images interpretation is accomplished through a combined analysis of two-dimensional source images and several types of three-dimensional renderings, with sensitivity around 96% in the detection of lesions with dimensions equal or greater than 10 mm in size, when analyzed by experienced radiologists. The present pictorial essay includes examples of diseases and pseudolesions most frequently observed in this type of imaging study. The authors present examples of flat and polypoid lesions, benign and malignant lesions, diverticular disease of the colon, among other conditions, as well as pseudolesions, including those related to inappropriate bowel preparation and misinterpretation. (author)

  20. Micro-computed tomography for small animal imaging: Technological details

    Institute of Scientific and Technical Information of China (English)

    Hao Li; Hui Zhang; Zhiwei Tang; Guangshu Hu

    2008-01-01

    The high-resolution micro-computed tomography(micro-CT)system has now become an important tool for biological research.The micro-CT system enables a non-invasive inspection to screen anatomical changes in small animals.The promising advantages include high-spatial resolution,high sensitivity to bone and lung,short scan time and cost-effectiveness.The dose received by the small animal might be a critical concern in the research.In this article,the choice of the components,fundamental physical problems,the image reconstruction algorithm and the representative applications of micro-CT are summarized.Some results from our research group are also presented to show high-resolution images obtained by the micro-CT system.

  1. Initial results of finger imaging using Photoacoustic Computed Tomography

    CERN Document Server

    van Es, Peter; Moens, Hein J Bernelot; Steenbergen, Wiendelt; Manohar, Srirang

    2014-01-01

    We present a photoacoustic computed tomography investigation on a healthy human finger, to image blood vessels with a focus on vascularity across the interphalangeal joints. The cross-sectional images were acquired using an imager specifically developed for this purpose. The images show rich detail of the digital blood vessels with diameters between 100 $\\mu$m and 1.5 mm in various orientations and at various depths. Different vascular layers in the skin including the subpapillary plexus could also be visualized. Acoustic reflections on the finger bone of photoacoustic signals from skin were visible in sequential slice images along the finger except at the location of the joint gaps. Not unexpectedly, the healthy synovial membrane at the joint gaps was not detected due to its small size and normal vascularization. Future research will concentrate on studying digits afflicted with rheumatoid arthritis to detect the inflamed synovium with its heightened vascularization, whose characteristics are potential marke...

  2. Common findings and pseudolesions at computed tomography colonography: pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Atzingen, Augusto Castelli von [Clinical Radiology, Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil); Tiferes, Dario Ariel; Matsumoto, Carlos Alberto; Nunes, Thiago Franchi; Maia, Marcos Vinicius Alvim Soares [Abdominal Imaging Section, Department of Imaging Diagnosis - Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil); D' Ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Department of Imaging Diagnosis, Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil)

    2012-05-15

    Computed tomography colonography is a minimally invasive method for screening for polyps and colorectal cancer, with extremely unusual complications, increasingly used in the clinical practice. In the last decade, developments in bowel preparation, imaging, and in the training of investigators have determined a significant increase in the method sensitivity. Images interpretation is accomplished through a combined analysis of two-dimensional source images and several types of three-dimensional renderings, with sensitivity around 96% in the detection of lesions with dimensions equal or greater than 10 mm in size, when analyzed by experienced radiologists. The present pictorial essay includes examples of diseases and pseudolesions most frequently observed in this type of imaging study. The authors present examples of flat and polypoid lesions, benign and malignant lesions, diverticular disease of the colon, among other conditions, as well as pseudolesions, including those related to inappropriate bowel preparation and misinterpretation. (author)

  3. Computed tomography dose index for head CT in northern Nigeria

    International Nuclear Information System (INIS)

    Computed tomography dose indexw and dose length product were recorded for the purpose of developing diagnostic reference levels (DRLs) for radiation dose optimisation. The study was conducted in three radiology departments with CT centres in Northern Nigeria. Data were collected from 54 consenting adult participants (weighing 70 kg±3) that had head CT scans. Analysis was done using SPSS version statistical software. A combined dose for the three centres was calculated and compared with the reported data from the international communities where there are established DRLs. Third quartile values of CTDIw and DLP were determined as 77 mGy and 985 mGy cm, respectively. Local DRLs that are significantly higher than most of the reported data in the literature have been established. (authors)

  4. Two Huge Maxillofacial Osteoma Cases Evaluated By Computed Tomography

    International Nuclear Information System (INIS)

    Osteomas are benign osteogenic neoplasms or hamartomas with a very slow growth rate. Osteoma is the most common mesenchymal neoplasm of the paranasal sinuses. In the jaws, the mandible is more commonly involved than the maxilla. Osteomas may occur at any age, but most frequently are found in individuals older than 40 years. Although most osteomas are small, some may become large enough to cause severe damage, especially those that develop in the frontoethmoid region. Osteomas composed solely of compact bone are uniformly radiopaque and those containing cancellous bone show evidence of internal trabecular structure. To determine and evaluate the exact extension and internal structure of these lesions, computed tomography (CT) is a more useful imaging modality in comparison to conventional radiography. Hereby, we discuss clinical and imaging features of two osteomas (one in the ethmoid sinus and the other in the mandible) along with the main differential diagnoses and pathologic features

  5. Inspection of a Medieval Wood Sculpture Using Computer Tomography

    Science.gov (United States)

    Kapitany, K.; Somogyi, A.; Barsi, A.

    2016-06-01

    Computer tomography (CT) is an excellent technique for obtaining accurate 3D information about the human body. It allows to visualize the organs, bones and blood vessels, furthermore it enables to diagnose anomalies and diseases. Its spatial reconstruction capability supports other interesting applications, such as inspecting different, even valuable objects like ancient sculptures. Current paper presents a methodology of evaluating CT and video imagery through the example of investigating a wood Madonna with infant Jesus sculpture from the 14th century. The developed techniques extract the outer boundary of the statue, which has been triangulated to derive the surface model. The interior of the sculpture has also been revealed: the iron bolts and rivets as well as the woodworm holes can be mapped. By merging the interior and outer data (geometry and texture) interesting visualizations (perspective views, sections etc.) have been created.

  6. Experimental study on computed tomography of the vestibular aqueduct

    Energy Technology Data Exchange (ETDEWEB)

    Kiuchi, Sousuke (Tsukuba Univ., Sakura, Ibaraki (Japan))

    1982-08-01

    Investigations of the vestibular aqueduct by computed tomography were performed in dry temporal bones and patients with unilateral sensorineural hearing loss. Using an accessory table for a wider aperture of the whole body scanner (CT/T-8800), it was possible to position patient's head for a direct sagittal plane of the temporal region on CT scans. The scans were employed with a 1.5-mm-thick slice with 1.5-mm slice space. In this study, it was proven that this method displayed the vestibular aqueduct as clearly in patients as in dry temporal bones. However, one of the disadvantages of this technique was uncomfortable positioning for some patients.

  7. Cone Beam Computed Tomography Evaluation of Inverted Mesiodentes.

    Science.gov (United States)

    Al-Sehaibany, Fares S; Marzouk, Hazem M; Salama, Fouad S

    2016-01-01

    A mesiodens is the most common type of supernumerary teeth. The purpose of this report is to present a rare occurrence of non-syndromic impacted inverted mesiodentes in an 8.5-year-old boy who presented with a chief complaint of delayed eruption of his permanent maxillary left central incisor. Occlusal and panoramic radiographs, as well as cone beam computed tomography (CBCT) with a three-dimensional (3-D) reconstruction image, confirmed that one supernumerary tooth had perforated the nasal fossa floor and the other was in close approximation to the to the same site. Surgical removal of both mesiodentes was indicated. Radiographic evidence of complete healing was observed 12 months following surgical removal. The use of CBCT with a 3-D reconstruction image as a tool in diagnosis and evaluation of healing after surgical removal is recommended. PMID:27620520

  8. Fossa navicularis magna detection on cone-beam computed tomography

    Science.gov (United States)

    Mupparapu, Mel

    2016-01-01

    Herein, we report and discuss the detection of fossa navicularis magna, a close radiographic anatomic variant of canalis basilaris medianus of the basiocciput, as an incidental finding in cone-beam computed tomography (CBCT) imaging. The CBCT data of the patients in question were referred for the evaluation of implant sites and to rule out pathology in the maxilla and mandible. CBCT analysis showed osseous, notch-like defects on the inferior aspect of the clivus in all four cases. The appearance of fossa navicularis magna varied among the cases. In some, it was completely within the basiocciput and mimicked a small rounded, corticated, lytic defect, whereas it appeared as a notch in others. Fossa navicularis magna is an anatomical variant that occurs on the inferior aspect of the clivus. The pertinent literature on the anatomical variations occurring in this region was reviewed. PMID:27051639

  9. Enhancement of photoacoustic tomography in the tissue with speed-of-sound variance using ultrasound computed tomography

    Science.gov (United States)

    Cheng, Ren-Xiang; Chao, Tao; Xiao-Jun, Liu

    2015-11-01

    The speed-of-sound variance will decrease the imaging quality of photoacoustic tomography in acoustically inhomogeneous tissue. In this study, ultrasound computed tomography is combined with photoacoustic tomography to enhance the photoacoustic tomography in this situation. The speed-of-sound information is recovered by ultrasound computed tomography. Then, an improved delay-and-sum method is used to reconstruct the image from the photoacoustic signals. The simulation results validate that the proposed method can obtain a better photoacoustic tomography than the conventional method when the speed-of-sound variance is increased. In addition, the influences of the speed-of-sound variance and the fan-angle on the image quality are quantitatively explored to optimize the image scheme. The proposed method has a good performance even when the speed-of-sound variance reaches 14.2%. Furthermore, an optimized fan angle is revealed, which can keep the good image quality with a low cost of hardware. This study has a potential value in extending the biomedical application of photoacoustic tomography. Projection supported by the National Basic Research Program of China (Grant No. 2012CB921504), the National Natural Science Foundation of China (Grant Nos. 11422439, 11274167, and 11274171), and the Specialized Research Fund for the Doctoral Program of Higher Education, China (Grant No. 20120091110001).

  10. Enhancement of photoacoustic tomography in the tissue with speed-of-sound variance using ultrasound computed tomography

    Institute of Scientific and Technical Information of China (English)

    程任翔; 陶超; 刘晓峻

    2015-01-01

    The speed-of-sound variance will decrease the imaging quality of photoacoustic tomography in acoustically inhomo-geneous tissue. In this study, ultrasound computed tomography is combined with photoacoustic tomography to enhance the photoacoustic tomography in this situation. The speed-of-sound information is recovered by ultrasound computed to-mography. Then, an improved delay-and-sum method is used to reconstruct the image from the photoacoustic signals. The simulation results validate that the proposed method can obtain a better photoacoustic tomography than the conventional method when the speed-of-sound variance is increased. In addition, the influences of the speed-of-sound variance and the fan-angle on the image quality are quantitatively explored to optimize the image scheme. The proposed method has a good performance even when the speed-of-sound variance reaches 14.2%. Furthermore, an optimized fan angle is revealed, which can keep the good image quality with a low cost of hardware. This study has a potential value in extending the biomedical application of photoacoustic tomography.

  11. Computed tomography-guided cutting needle biopsy of pulmonary lesions

    Directory of Open Access Journals (Sweden)

    Yu Liao Shin

    2002-01-01

    Full Text Available PURPOSE: To report the experience of a radiology department in the use of computed tomography - guided cutting needle biopsy of pulmonary nodules, by evaluating diagnostic yield and incidence of complications. METHODS: This is a retrospective analysis of 52 consecutive patients who underwent lung lesion biopsy guided by computed tomography, performed between May 1997 and May 2000. Thirty-five patients were male and 17 were female, with ages ranging from 5 to 85 years (median, 62 years. The size of the lesions ranged from 1.8 to 15 cm (median, 5.4 cm. RESULTS: In a total of 52 biopsies of lung lesions, 51 biopsies (98.1% supplied appropriate material for histopathological diagnosis, with 9 diagnosed (17.3% as benign and 42 (80.8% as malignant lesions. Specific diagnosis was obtained in 44 (84.6% biopsies: 4 benign (9.1% and 40 (90.9% malignant lesions. The sensitivity, specificity, and accuracy of the cutting needle biopsies for determining presence of malignancy were 96.8%, 100%, and 97.2%, respectively. Complications occurred in 9 cases (17.3%, including 6 cases (11.5% of small pneumothorax, 1 (1.9% of hemoptysis, 1 (1.9% of pulmonary hematoma, and 1 (1.9% of thoracic wall hematoma. All had spontaneous resolution. There were no complications requiring subsequent intervention. CONCLUSION: The high sensitivity and specificity of the method and the low rate of complications have established cutting needle biopsy as an efficient and safe tool for the diagnosis of lung lesions. In our hospital, cutting needle biopsy is considered a reliable procedure for the evaluation of indeterminate pulmonary nodules.

  12. Computed tomography - guided cutting needle biopsy of pulmonary lesions

    International Nuclear Information System (INIS)

    The purpose of this study was to report the experience of a radiology department in the use of computed tomography-guided cutting needle biopsy of pulmonary nodules, by evaluating diagnostic yield and incidence of complications. This is a retrospective analysis of 52 consecutive patients who underwent lung lesion biopsy guided by computed tomography, performed between May 1997 and May 2000. Thirty-five patients were male and 17 were female, with ages ranging from 5 to 85 years (median, 62 years). The size of the lesions ranged from 1.8 to 15 cm (median, 5.4 cm). In a total of 52 biopsies of lung lesions, 51 biopsies (98.1%) supplied appropriate material for histopathological diagnosis, with 9 diagnosed (17.3%) as benign and 42 (80.8%) as malignant lesions. Specific diagnosis was obtained in 44 (84.6%) biopsies: 4 benign (9.1%) and 40 (90.9%) malignant lesions. The sensitivity, specificity, and accuracy of the cutting needle biopsies for determining presence of malignancy were 96.8%, 100%, and 97.2%, respectively. Complications occurred in 9 cases (17.3%), including 6 cases (11.5%) of small pneumothorax, 1 (1.9%) of hemoptysis, 1 (1.9%) of pulmonary hematoma, and 1 (1.9%) of thoracic wall hematoma. All had spontaneous resolution. There were no complications requiring subsequent intervention. The high sensitivity and specificity of the method and the low rate of complications have established cutting needle biopsy as an efficient and safe tool for the diagnosis of lung lesions. In our hospital, cutting needle biopsy is considered a reliable procedure for the evaluation of indeterminate pulmonary nodules. (author)

  13. Computed tomography - guided cutting needle biopsy of pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Liao Shin Yu; Deheinzelin, Daniel; Younes, Riad N.; Chojniak, Rubens [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radiologia e Cirurgia Toracica; Universidade Paulista (UNIP), SP (Brazil)

    2002-02-01

    The purpose of this study was to report the experience of a radiology department in the use of computed tomography-guided cutting needle biopsy of pulmonary nodules, by evaluating diagnostic yield and incidence of complications. This is a retrospective analysis of 52 consecutive patients who underwent lung lesion biopsy guided by computed tomography, performed between May 1997 and May 2000. Thirty-five patients were male and 17 were female, with ages ranging from 5 to 85 years (median, 62 years). The size of the lesions ranged from 1.8 to 15 cm (median, 5.4 cm). In a total of 52 biopsies of lung lesions, 51 biopsies (98.1%) supplied appropriate material for histopathological diagnosis, with 9 diagnosed (17.3%) as benign and 42 (80.8%) as malignant lesions. Specific diagnosis was obtained in 44 (84.6%) biopsies: 4 benign (9.1%) and 40 (90.9%) malignant lesions. The sensitivity, specificity, and accuracy of the cutting needle biopsies for determining presence of malignancy were 96.8%, 100%, and 97.2%, respectively. Complications occurred in 9 cases (17.3%), including 6 cases (11.5%) of small pneumothorax, 1 (1.9%) of hemoptysis, 1 (1.9%) of pulmonary hematoma, and 1 (1.9%) of thoracic wall hematoma. All had spontaneous resolution. There were no complications requiring subsequent intervention. The high sensitivity and specificity of the method and the low rate of complications have established cutting needle biopsy as an efficient and safe tool for the diagnosis of lung lesions. In our hospital, cutting needle biopsy is considered a reliable procedure for the evaluation of indeterminate pulmonary nodules. (author)

  14. Sex estimation from sternal measurements using multidetector computed tomography.

    Science.gov (United States)

    Ekizoglu, Oguzhan; Hocaoglu, Elif; Inci, Ercan; Bilgili, Mustafa Gokhan; Solmaz, Dilek; Erdil, Irem; Can, Ismail Ozgur

    2014-12-01

    We aimed to show the utility and reliability of sternal morphometric analysis for sex estimation.Sex estimation is a very important step in forensic identification. Skeletal surveys are main methods for sex estimation studies. Morphometric analysis of sternum may provide high accuracy rated data in sex discrimination. In this study, morphometric analysis of sternum was evaluated in 1 mm chest computed tomography scans for sex estimation. Four hundred forty 3 subjects (202 female, 241 male, mean age: 44 ± 8.1 [distribution: 30-60 year old]) were included the study. Manubrium length (ML), mesosternum length (2L), Sternebra 1 (S1W), and Sternebra 3 (S3W) width were measured and also sternal index (SI) was calculated. Differences between genders were evaluated by student t-test. Predictive factors of sex were determined by discrimination analysis and receiver operating characteristic (ROC) analysis. Male sternal measurement values are significantly higher than females (P < 0.001) while SI is significantly low in males (P < 0.001). In discrimination analysis, MSL has high accuracy rate with 80.2% in females and 80.9% in males. MSL also has the best sensitivity (75.9%) and specificity (87.6%) values. Accuracy rates were above 80% in 3 stepwise discrimination analysis for both sexes. Stepwise 1 (ML, MSL, S1W, S3W) has the highest accuracy rate in stepwise discrimination analysis with 86.1% in females and 83.8% in males. Our study showed that morphometric computed tomography analysis of sternum might provide important information for sex estimation. PMID:25501090

  15. Studies On Quantitative Analysis Of Salivary Gland Using Computed Tomography

    International Nuclear Information System (INIS)

    The purpose of this study was to calculate the size and CT number of both normal parotid and submandibular gland, and evaluate its relation to sex, age and obesity using computed tomography. The computed tomography was performed parallel to the Frankfurt plane in 46 subjects with healthy salivary gland. The subjects were divided into the three groups (young, middle, old) according to their ages. The size of salivary gland was determined as maximum cross-sectional area and the CT number of salivary gland was determined as the mean CT number of three ROI's. The body mass index was calculated from weight and height. The mean maximum cross-sectional area was 7.79 (+/-1.26) cm2 on parotid gland and 4.12 (+/-0.83) cm2 on submandibular gland. The mean CT number was -4.43 (+/-23.87) HU on parotid gland and 50.01 (+/-15.63) HU on submandibular gland. There were decreasing pattern of the maximum cross-sectional area of submandibular gland and the CT number of both parotid and submandibular gland according to age (p<0.05). As the body mass index increased, the maximum cross-sectional area of parotid gland increased and CT number of both parotid and submandibular gland decreased (p<0.05). The maximum cross-sectional area of submandibular gland in male was larger than that in female (p<0.05). As the maximum cross-sectional area and CT number of left salivary gland increased, those of right gland increased (p<0.05). Intra-individual differences in salivary gland size and CT number is considered in the age and individual obesity.

  16. Pore scale definition and computation from tomography data

    Science.gov (United States)

    Dupuy, P. M.; Austin, P.; Delaney, G. W.; Schwarz, M. P.

    2011-10-01

    During recent years characterisation capabilities of porous media have been transformed by advances in computation and visualisation technologies. It is now possible to obtain detailed topological and hydrodynamic information of porous media by combining tomographic and computational fluid dynamic studies. Despite the existence of these new capabilities, the characterisation process itself is based on the same antiquated experimental macroscopic concepts. We are interested in an up-scaling process where we can keep key information for every pore size present in the media in order to feed multi-scale transport models. Hydrometallurgical, environmental, food, pharmaceutical and chemical engineering are industries with process outcomes based on homogeneous and heterogeneous reactions and therefore sensitive to the reaction and transport processes happening at different pore scales. The present work addresses a key step in the information up-scaling process, i.e. a pore identification algorithm similar to alternating sequential filters. In a preliminary study, topological and hydrodynamic variables are correlated with the pore size. Micrometre and millimetre resolution tomographies are used to characterise the pore size distribution of a packed column and different rocks. Finally, we compute the inter-pore-scale redistribution function which is a measure of the heterogeneity of the media and magnitude needed in multi-scale modelling.

  17. Artifacts in computed tomography scanning of moving objects.

    Science.gov (United States)

    Chen, George T Y; Kung, Jong H; Beaudette, Kevin P

    2004-01-01

    Target volumes in the thorax and abdomen are commonly computed tomography (CT) scanned during light respiration. In this article, we analyze the distortions introduced in helical scanning of moving objects. Objects of known geometry are placed on a moving sled and scanned in a multirow helical CT scanner. The motion of the sled approximates the magnitude and velocity of organ movement in patients during light respiration (amplitude 1 cm, period 4 seconds). Scans of the phantom are obtained in high speed mode at incremental phases of respiration, and the resulting images are compared with scans obtained when the phantom is static. Computer simulations of the scan process are also performed to interpret the results and extend the analysis to a greater range of parameters in scanning, motion, and object size. Resulting scans show that spherical test objects can be shortened by as much as 2 cm or twice the periodic motion amplitude. Object shape was significantly distorted, and the geometric center of the object was displaced by as much as +/-0.8 cm. Computer simulation results qualitatively agree with the experimentally observed phantom images. These simulations predict that the effect is clearly observable even if the amplitude is decreased to 0.5 cm. Implications of scanning moving objects on treatment planning are discussed.

  18. Patterns of brown fat uptake of 18F-fluorodeoxyglucose in positron emission tomography/computed tomography scan

    International Nuclear Information System (INIS)

    Fluorodeoxyglucose (FDG) positron emission tomography (PET) has become the common imaging modality in oncological practice. FDG uptake is seen in brown adipose tissue in a significant number of patients. Recognizing the uptake patterns is important for optimal FDG PET interpretation. The introduction of PET/computed tomography (PET/CT) revolutionized PET imaging, bringing much-needed anatomical information. Careful review and correlation of FDG PET images with anatomical imaging should be performed to characterize accurately any lesion having high FDG uptake

  19. Fluorodeoxyglucose positron emission tomography/computed tomography and magnetic resonance imaging of uterine leiomyosarcomas: 2 cases report

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hui-juan; ZHAN Feng-hua; LI Ya-jun; SUN Hao-ran; BAI Ren-ju; GAO Shuo

    2011-01-01

    Uterine leiomyosarcoma is an uncommon malignant neoplasm of smooth muscle origination and is associated with a poor prognosis. We report two cases of uterine leiomyosarcoma that presented with pulmonary metastases.2-deoxy-2-(18F)fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) was performed to identify the primary carcinoma and found the focus located in the uterus. The follow-up magnetic resonance imaging (MRI) confirmed the diagnosis was uterine leiomyosarcoma.

  20. Diagnostic Value of Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in a Patient with Adrenal Involvement of Hodgkin Lymphoma

    OpenAIRE

    Doğan Köse; Yavuz Köksal

    2016-01-01

    Improved success with the modern management of Hodgkin lymphoma (HL) leaded new method searches to diminish treatment intensities in order to prevent late effects. Sensitivity and specificity of fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) is advanced in the determination of malign cell infiltrations in adrenal glands in patients with HL which is a rare finding. A 7.5 year old female patient that was investigated due to pubic hairs and breast development ...

  1. Splenic and lymph nodal involvement in sarcoidosis mimicking lymphoma on fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography

    OpenAIRE

    Jung, Rayamajhi Sampanna; Mittal, Bhagwant Rai; Maturu, Nagarjuna Venkata; Bal, Amanjit; Bhattacharya, Anish; Gupta, Dheeraj

    2015-01-01

    Sarcoidosis is a multisystemic disease presenting with well-defined, bilateral, symmetric hilar and right paratracheal lymph node enlargement. Recently, fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) has been used to stage and detect occult site of active inflammation in sarcoidosis. F-18 FDG PET/CT has become a cornerstone imaging modality in the modern lymphoma management, which can present with generalized lymphadenopathy including mediast...

  2. Time-Domain Terahertz Computed Axial Tomography NDE System

    Science.gov (United States)

    Zimdars, David

    2012-01-01

    NASA has identified the need for advanced non-destructive evaluation (NDE) methods to characterize aging and durability in aircraft materials to improve the safety of the nation's airline fleet. 3D THz tomography can play a major role in detection and characterization of flaws and degradation in aircraft materials, including Kevlar-based composites and Kevlar and Zylon fabric covers for soft-shell fan containment where aging and durability issues are critical. A prototype computed tomography (CT) time-domain (TD) THz imaging system has been used to generate 3D images of several test objects including a TUFI tile (a thermal protection system tile used on the Space Shuttle and possibly the Orion or similar capsules). This TUFI tile had simulated impact damage that was located and the depth of damage determined. The CT motion control gan try was designed and constructed, and then integrated with a T-Ray 4000 control unit and motion controller to create a complete CT TD-THz imaging system prototype. A data collection software script was developed that takes multiple z-axis slices in sequence and saves the data for batch processing. The data collection software was integrated with the ability to batch process the slice data with the CT TD-THz image reconstruction software. The time required to take a single CT slice was decreased from six minutes to approximately one minute by replacing the 320 ps, 100-Hz waveform acquisition system with an 80 ps, 1,000-Hz waveform acquisition system. The TD-THZ computed tomography system was built from pre-existing commercial off-the-shelf subsystems. A CT motion control gantry was constructed from COTS components that can handle larger samples. The motion control gantry allows inspection of sample sizes of up to approximately one cubic foot (.0.03 cubic meters). The system reduced to practice a CT-TDTHz system incorporating a COTS 80- ps/l-kHz waveform scanner. The incorporation of this scanner in the system allows acquisition of 3D

  3. Role of computed tomography and radionuclide scintigraphy in the localization of osteomyelitis in flat bones

    International Nuclear Information System (INIS)

    The combined use of radionuclide scintigraphy and computed tomography is recommended for evaluating children with laboratory and clinical data suggestive of flat bone osteomyelitis despite normal conventional radiographs. In addition, computed tomography may be helpful in the presence of abnormal radiographs in determining the exact location of the focus of osteomyelitis and the most suitable route for appropriate drainage or to obtain culture material

  4. Role of computed tomography and radionuclide scintigraphy in the localization of osteomyelitis in flat bones

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, R.J.; Conway, J.J.; Poznanski, A.K.; Tachdjian, M.O.; Dias, L.S.; Kelikian, A.S.

    1985-03-01

    The combined use of radionuclide scintigraphy and computed tomography is recommended for evaluating children with laboratory and clinical data suggestive of flat bone osteomyelitis despite normal conventional radiographs. In addition, computed tomography may be helpful in the presence of abnormal radiographs in determining the exact location of the focus of osteomyelitis and the most suitable route for appropriate drainage or to obtain culture material.

  5. Computed tomography in children: multicenter cohort study design for the evaluation of cancer risk

    International Nuclear Information System (INIS)

    Exposure to ionizing radiation is a known risk factor for cancer. Cancer risk is highest after exposure in childhood. The computed tomography is the major contributor to the average, individual radiation exposure. Until now the association has been addressed only in statistical modeling. We present the first feasible study design on childhood cancer risk after exposure to computed tomography.

  6. Complete disappearance of lung abnormalities on high-resolution computed tomography: A case of histiocytosis X

    OpenAIRE

    2007-01-01

    A case of pulmonary Langerhans cell histiocytosis, proved by both lung high-resolution computed tomography and lung biopsy, is described. Following smoking cessation, lung nodules and cysts gradually disappeared on serial computed tomography scans, with complete clearance of the lesions after 12 months. The role of tobacco smoking is discussed, in detail, against the background of the literature.

  7. Computed tomography of the chest in blunt thoracic trauma: results of a prospective study

    International Nuclear Information System (INIS)

    Blunt thoracic injuries detected by computed tomography of the chest infrequently require immediate therapy. If immediate therapy is needed, findings will be visible on plain roentgenograms or on clinical exam. Routine Computed Tomography of the chest in blunt trauma is not recommended but may be helpful in selected cases. (N.C.)

  8. 3D SPIRAL COMPUTED TOMOGRAPHY FOR THE DIAGNOSIS OF AN ABDOMINAL TUMOUR

    OpenAIRE

    R.C. Tiutiuca; Iuliana Eva

    2006-01-01

    Patients with digestive illnesses requires a full exploration, cases where imagistic assets support (echographic examination, radiological data, computed tomography, magnetic resonance) are very usefully. Computed tomography, in this process, has a special value. The results from axial images are sustained by the informations supplied from three-dimensional reconstruction processes (3D reconstruction) with relevant importance in establishment of diagnosis and therapeutic plan.

  9. Quantitative computed tomography measures of emphysema and airway wall thickness are related to respiratory symptoms

    DEFF Research Database (Denmark)

    Grydeland, Thomas B; Dirksen, Asger; Coxson, Harvey O;

    2010-01-01

    There is limited knowledge about the relationship between respiratory symptoms and quantitative high-resolution computed tomography measures of emphysema and airway wall thickness.......There is limited knowledge about the relationship between respiratory symptoms and quantitative high-resolution computed tomography measures of emphysema and airway wall thickness....

  10. High precision semiautomated computed tomography measurement of lumbar disk and vertebral heights

    OpenAIRE

    Tan, Sovira; Yao, Jianhua; Yao, Lawrence; Ward, Michael M.

    2012-01-01

    Purpose: Evaluation of treatments of many spine disorders requires precise measurement of the heights of vertebral bodies and disk spaces. The authors present a semiautomated computer algorithm measuring those heights from spine computed tomography (CT) scans and evaluate its precision.

  11. Highly metabolic thrombus of the portal vein: 18F fluorodeoxyglucose positron emission tomography/computer tomography demonstration and clinical significance in hepatocellular carcinoma

    OpenAIRE

    Sun, Long; Guan, Yong-Song; Pan, Wei-Ming; Chen, Gui-Bing; Luo, Zuo-Ming; Wei, Ji-Hong; Wu, Hua

    2008-01-01

    AIM: To assess the ability of 18F-fluorodeoxyglucose positron emission tomography/computer tomography (18F-FDG PET/CT) to differentiate between benign and malignant portal vein thrombosis in hepatocellular carcinoma (HCC) patients.

  12. Comparison of Adsorbed Skin Dose Received by Patients in Cone Beam Computed Tomography, Spiral and Conventional Computed Tomography Scanninng

    Directory of Open Access Journals (Sweden)

    Rahimi A

    2011-12-01

    Full Text Available Background and Aims: The evaluation of absorbed dose received by patients could give useful information for radiation risk estimation. This study was performed to compare the entrance skin dose received by patients in cone beam computed tomography (CBCT, conventional and spiral computed tomography (CT.Materials and Methods: In this experimental study, 81 calibrated TLD chips were used. the TLD chips were placed on facial, thyroid and end of sternum skin surface in patients referred for CT of the paranasal sinuses(3 TLD chips for each area to estimate the absorbed dose received by central part of radiation field, thyroid and out of field areas, respectively. The data were analyzed using one-way ANOVA and Tukey tests. Results: The dose delivered to the center of irradiated field was about 0.79±0.09 mGy in CBCT technique compared with 16.31±3.71 and 18.84±4.12 mGy for spiral and conventional CT, respectively. The received dose by the out of field areas was about 54 percent of central area dose. There was statistical significant relationship between the imaging modalities and absorbed dose received by patients (P=0.016. The least absorbed dose was for CBCT and the greatest dose was for conventional CT imaging technique.Conclusion: The dose delivered to central area of irradiated field in conventional and spiral CT imaging modalities was about 24 times greater than of that in CBCT. Also, the highest received dose was for central area of radiated field and the lowest dose was for the out of field areas.

  13. Comparison of the radiation dose from cone beam computed tomography and multidetector computed tomography in examinations of the hand

    International Nuclear Information System (INIS)

    Comparison of radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in examinations of the hand. Dose calculations were carried out by means of Monte Carlo simulations in MDCT and CBCT. A corpse hand was examined in a 320-row MDCT scanner and a dedicated extremities CBCT scanner with standard protocols and multiple low-dose protocols. The image quality of the examinations was evaluated by 5 investigators using a Likert scale from 1 (very good) to 5 (very poor) regarding depiction of cortical bone, cancellous bone, joint surfaces, soft tissues and artifacts. For a sum of ratings of all structures < 50 a good overall image quality was expected. The studies with at least good overall image quality were compared with respect to the dose. The dose of the standard examination was 13.21 (12.96 to 13.46 CI) mGy in MDCT and 7.15 (6.99 to 7.30 CI) mGy in CBCT. The lowest dose in a study with good overall image quality was 4.54 (4.43 to 4.64 CI) mGy in MDCT and 5.72 (5.59 to 5.85 CI) mGy in CBCT. Although the dose of the standard protocols in the CBCT is lower than in the MDCT, the MDCT can realize a good overall image quality at a lower dose than the CBCT. Dose optimization of CT examination protocols for the hand is useful in both modalities, the MDCT has an even greater potential for optimization.

  14. A Theory of Ambulance Chasing

    CERN Document Server

    Backović, Mihailo

    2016-01-01

    Ambulance chasing is a common socio-scientific phenomenon in particle physics. I argue that despite the seeming complexity, it is possible to gain insight into both the qualitative and quantitative features of ambulance chasing dynamics. Compound-Poisson statistics suffices to accommodate the time evolution of the cumulative number of papers on a topic, where basic assumptions that the interest in the topic as well as the number of available ideas decrease with time appear to drive the time evolution. It follows that if the interest scales as an inverse power law in time, the cumulative number of papers on a topic is well described by a di-gamma function, with a distinct logarithmic behavior at large times. In cases where the interest decreases exponentially with time, the model predicts that the total number of papers on the topic will converge to a fixed value as time goes to infinity. I demonstrate that the two models are able to fit at least 9 specific instances of ambulance chasing in particle physics us...

  15. Dynamic 3D computed tomography scanner for vascular imaging

    Science.gov (United States)

    Lee, Mark K.; Holdsworth, David W.; Fenster, Aaron

    2000-04-01

    A 3D dynamic computed-tomography (CT) scanner was developed for imaging objects undergoing periodic motion. The scanner system has high spatial and sufficient temporal resolution to produce quantitative tomographic/volume images of objects such as excised arterial samples perfused under physiological pressure conditions and enables the measurements of the local dynamic elastic modulus (Edyn) of the arteries in the axial and longitudinal directions. The system was comprised of a high resolution modified x-ray image intensifier (XRII) based computed tomographic system and a computer-controlled cardiac flow simulator. A standard NTSC CCD camera with a macro lens was coupled to the electro-optically zoomed XRII to acquire dynamic volumetric images. Through prospective cardiac gating and computer synchronized control, a time-resolved sequence of 20 mm thick high resolution volume images of porcine aortic specimens during one simulated cardiac cycle were obtained. Performance evaluation of the scanners illustrated that tomographic images can be obtained with resolution as high as 3.2 mm-1 with only a 9% decrease in the resolution for objects moving at velocities of 1 cm/s in 2D mode and static spatial resolution of 3.55 mm-1 with only a 14% decrease in the resolution in 3D mode for objects moving at a velocity of 10 cm/s. Application of the system for imaging of intact excised arterial specimens under simulated physiological flow/pressure conditions enabled measurements of the Edyn of the arteries with a precision of +/- kPa for the 3D scanner. Evaluation of the Edyn in the axial and longitudinal direction produced values of 428 +/- 35 kPa and 728 +/- 71 kPa, demonstrating the isotropic and homogeneous viscoelastic nature of the vascular specimens. These values obtained from the Dynamic CT systems were not statistically different (p less than 0.05) from the values obtained by standard uniaxial tensile testing and volumetric measurements.

  16. X-ray computed tomography for casting development

    Science.gov (United States)

    Georgeson, Gary E.; Crews, Alan R.; Bossi, Richard H.

    1992-09-01

    Computed tomography (CT) has been used to evaluate specific sand casting product examples for technical and economic benefits. The representative results are applicable to other casting technologies as well. CT has been shown to be cost effective in the development of new castings. The areas which would benefit include internal dimensional measurements (eliminating destructive sectioning), specific region inspections, flaw characterization in critical regions (to allow passing or informed repair of castings), and geometric acquisition for CAD/CAM. The quantitative capability of CT allows an engineering evaluation of castings based upon a correlation with performance. This quantitative measurement capability has also been used to measure the benefit of hot isostatic pressing in casting production. CT is also cost effective for engineering design and analysis by providing rapid geometry acquisition for input to computer aided design systems. This is particularly beneficial for components that do not have existing drawings or cannot be adequately defined until they are made for any reason. Presently CT can serve as an engineering aid to casting manufacturing. In order for CT evaluation to become routine in foundry applications, however, casting designers need to call it out as a measurement technique in the original casting design drawings, specifications on the application of CT must be written, contracts must include CT evaluation as a means for accepting casting quality, and lower cost CT systems must be available.

  17. A Novel Automated Method for Analyzing Cylindrical Computed Tomography Data

    Science.gov (United States)

    Roth, D. J.; Burke, E. R.; Rauser, R. W.; Martin, R. E.

    2011-01-01

    A novel software method is presented that is applicable for analyzing cylindrical and partially cylindrical objects inspected using computed tomography. This method involves unwrapping and re-slicing data so that the CT data from the cylindrical object can be viewed as a series of 2-D sheets in the vertical direction in addition to volume rendering and normal plane views provided by traditional CT software. The method is based on interior and exterior surface edge detection and under proper conditions, is FULLY AUTOMATED and requires no input from the user except the correct voxel dimension from the CT scan. The software is available from NASA in 32- and 64-bit versions that can be applied to gigabyte-sized data sets, processing data either in random access memory or primarily on the computer hard drive. Please inquire with the presenting author if further interested. This software differentiates itself in total from other possible re-slicing software solutions due to complete automation and advanced processing and analysis capabilities.

  18. Inexpensive computed tomography for remote areas via teleradiology

    Science.gov (United States)

    Gordon, Richard

    1990-06-01

    While x-ray computed tomography (CT) is falling in price it is still beyond the means of most primary and secondary health care centres in the world. I would like to show how if a teleradiology system is installed there is a good prospect for also being able to install a simple but diagnostically effective CT system. This can be based on film used either as a one or two dimensional detector. 1. CT SYSTEMS The major components of a CT system are: 1) health care worker(s) who can decide which part of a patient needs to be imaged 2) an x-ray transparent bed on which a patient can be made comfortable positioned and restrained as necessary 3) an x-ray source mounted on a gantry 4) an x-ray detector mounted on the gantry 5) a digitizer for the x-ray signal 6) a computer to receive the signal 7) an algorithm that calculates the reconstructed CT image 8) a halftone or color display monitor 9) a radiologist who can interpret the images 10) communication from the radiologist to the health care worker(s). 2. BENEFITS OF CT VIA TELERADIOLOGY I would like to proceed on the premise that a teleradiology system could be placed between steps 6 and 7. This has the following benefits: a) Radiologists who are relatively scarce and generally located in urban tertiary care centres could serve people in remote areas

  19. Compensation for air voids in photoacoustic computed tomography image reconstruction

    Science.gov (United States)

    Matthews, Thomas P.; Li, Lei; Wang, Lihong V.; Anastasio, Mark A.

    2016-03-01

    Most image reconstruction methods in photoacoustic computed tomography (PACT) assume that the acoustic properties of the object and the surrounding medium are homogeneous. This can lead to strong artifacts in the reconstructed images when there are significant variations in sound speed or density. Air voids represent a particular challenge due to the severity of the differences between the acoustic properties of air and water. In whole-body small animal imaging, the presence of air voids in the lungs, stomach, and gastrointestinal system can limit image quality over large regions of the object. Iterative reconstruction methods based on the photoacoustic wave equation can account for these acoustic variations, leading to improved resolution, improved contrast, and a reduction in the number of imaging artifacts. However, the strong acoustic heterogeneities can lead to instability or errors in the numerical wave solver. Here, the impact of air voids on PACT image reconstruction is investigated, and procedures for their compensation are proposed. The contributions of sound speed and density variations to the numerical stability of the wave solver are considered, and a novel approach for mitigating the impact of air voids while reducing the computational burden of image reconstruction is identified. These results are verified by application to an experimental phantom.

  20. 3D ultrasound computer tomography: update from a clinical study

    Science.gov (United States)

    Hopp, T.; Zapf, M.; Kretzek, E.; Henrich, J.; Tukalo, A.; Gemmeke, H.; Kaiser, C.; Knaudt, J.; Ruiter, N. V.

    2016-04-01

    Ultrasound Computer Tomography (USCT) is a promising new imaging method for breast cancer diagnosis. We developed a 3D USCT system and tested it in a pilot study with encouraging results: 3D USCT was able to depict two carcinomas, which were present in contrast enhanced MRI volumes serving as ground truth. To overcome severe differences in the breast shape, an image registration was applied. We analyzed the correlation between average sound speed in the breast and the breast density estimated from segmented MRIs and found a positive correlation with R=0.70. Based on the results of the pilot study we now carry out a successive clinical study with 200 patients. For this we integrated our reconstruction methods and image post-processing into a comprehensive workflow. It includes a dedicated DICOM viewer for interactive assessment of fused USCT images. A new preview mode now allows intuitive and faster patient positioning. We updated the USCT system to decrease the data acquisition time by approximately factor two and to increase the penetration depth of the breast into the USCT aperture by 1 cm. Furthermore the compute-intensive reflectivity reconstruction was considerably accelerated, now allowing a sub-millimeter volume reconstruction in approximately 16 minutes. The updates made it possible to successfully image first patients in our ongoing clinical study.