WorldWideScience

Sample records for characterization physical testing

  1. Validation of the Physics Analysis used to Characterize the AGR-1 TRISO Fuel Irradiation Test

    Energy Technology Data Exchange (ETDEWEB)

    Sterbentz, James W.; Harp, Jason M.; Demkowicz, Paul A.; Hawkes, Grant L.; Chang, Gray S.

    2015-05-01

    The results of a detailed physics depletion calculation used to characterize the AGR-1 TRISO-coated particle fuel test irradiated in the Advanced Test Reactor (ATR) at the Idaho National Laboratory are compared to measured data for the purpose of validation. The particle fuel was irradiated for 13 ATR power cycles over three calendar years. The physics analysis predicts compact burnups ranging from 11.30-19.56% FIMA and cumulative neutron fast fluence from 2.21?4.39E+25 n/m2 under simulated high-temperature gas-cooled reactor conditions in the ATR. The physics depletion calculation can provide a full characterization of all 72 irradiated TRISO-coated particle compacts during and post-irradiation, so validation of this physics calculation was a top priority. The validation of the physics analysis was done through comparisons with available measured experimental data which included: 1) high-resolution gamma scans for compact activity and burnup, 2) mass spectrometry for compact burnup, 3) flux wires for cumulative fast fluence, and 4) mass spectrometry for individual actinide and fission product concentrations. The measured data are generally in very good agreement with the calculated results, and therefore provide an adequate validation of the physics analysis and the results used to characterize the irradiated AGR-1 TRISO fuel.

  2. Sampling and physical and actinide characterization of colloids from the Grimsel test site

    International Nuclear Information System (INIS)

    Longworth, G.; Ivanovich, M.

    1990-01-01

    Samples of groundwater from a granite fracture at the Grimsel test site in Switzerland have been collected as part of a second intercomparison of groundwater colloid sampling and characterization techniques carried out by members of the Coco Club (colloids and complexes) sponsored by the CEC. This report describes the Harwell contribution to this exercise. The bulk of naturally occurring actinides were found to reside in solution with 10 particles/I (detection limit ∼50 nm) for samples determined by three laboratories. The colloids were shown to be negatively charged using microelectrophoresis and to be relatively stable. There was evidence of a reduction in the pH of the water after storage due to air contamination. This work has served to identify the problems associated with colloid sampling and characterization techniques

  3. Towards Modernizing the Characterization of Shock and Detonation Physics Performance via Novel Diagnostics and Tests

    Science.gov (United States)

    Salyer, Terry

    2017-06-01

    For the bulk of detonation performance experiments, a fairly basic set of diagnostic techniques has evolved as the standard for acquiring the necessary measurements. Gold standard techniques such as pin switches and streak cameras still produce the high-quality data required, yet much room remains for improvement with regard to ease of use, cost of fielding, breadth of data, and diagnostic versatility. Over the past several years, an alternate set of diagnostics has been under development to replace many of these traditional techniques. Pulse Correlation Reflectometry (PCR) is a capable substitute for pin switches with the advantage of obtaining orders of magnitude more data at a small fraction of the cost and fielding time. Spectrally Encoded Imaging (SEI) can replace most applications of streak camera with the advantage of imaging surfaces through a single optical fiber that are otherwise optically inaccessible. Such diagnostics advance the measurement state of the art, but even further improvements may come through revamping the standardized tests themselves such as the copper cylinder expansion test. At the core of this modernization, the aforementioned diagnostics play a significant role in revamping and improving the standard test suite for the present era. This research was performed under the auspices of the United States Department of Energy.

  4. Mound facility physical characterization

    Energy Technology Data Exchange (ETDEWEB)

    Tonne, W.R.; Alexander, B.M.; Cage, M.R.; Hase, E.H.; Schmidt, M.J.; Schneider, J.E.; Slusher, W.; Todd, J.E.

    1993-12-01

    The purpose of this report is to provide a baseline physical characterization of Mound`s facilities as of September 1993. The baseline characterizations are to be used in the development of long-term future use strategy development for the Mound site. This document describes the current missions and alternative future use scenarios for each building. Current mission descriptions cover facility capabilities, physical resources required to support operations, current safety envelope and current status of facilities. Future use scenarios identify potential alternative future uses, facility modifications required for likely use, facility modifications of other uses, changes to safety envelope for the likely use, cleanup criteria for each future use scenario, and disposition of surplus equipment. This Introductory Chapter includes an Executive Summary that contains narrative on the Functional Unit Material Condition, Current Facility Status, Listing of Buildings, Space Plans, Summary of Maintenance Program and Repair Backlog, Environmental Restoration, and Decontamination and Decommissioning Programs. Under Section B, Site Description, is a brief listing of the Site PS Development, as well as Current Utility Sources. Section C contains Site Assumptions. A Maintenance Program Overview, as well as Current Deficiencies, is contained within the Maintenance Program Chapter.

  5. GRE physics test

    CERN Document Server

    Fakhrudin, Hasan

    2010-01-01

    Designed for students and professionals looking to advance their careers, our test prep gives you everything you need to succeed. Focused chapter reviews cover all the information tested on the GRE Physics exam. Each review chapter contains examples to reinforce key concepts. The book includes four full-length practice tests based on the most recent GRE Physics exam. Each test contains every type of question that can be expected on the GRE so you can “practice for real” and boost your confidence before taking the exam.

  6. The characterization, replication and testing of dermal denticles of Scyliorhinus canicula for physical mechanisms of biofouling prevention

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, Timothy; Regan, Fiona, E-mail: fiona.regan@dcu.ie [Marine and Environmental Sensing Technology Hub (MESTECH), National Centre for Sensor Research, School of Chemical Sciences, Dublin City University, Glasnevin, Dublin 9 (Ireland)

    2011-12-15

    There is a current need to develop novel non-toxic antifouling materials. The mechanisms utilized by marine organisms to prevent fouling of external surfaces are of interest in this regard. Biomimicry of these mechanisms and the ability to transfer the antifouling characteristics of these surfaces to artificial surfaces are a highly attractive prospect to those developing antifouling technologies. In order to achieve this, the mechanisms responsible for any antifouling ability must be elucidated from the study of the natural organism and the critical surface parameters responsible for fouling reduction. Dermal denticles of members of the shark family have been speculated to possess some natural, as yet unidentified antifouling mechanism related to the physical presence of denticles. In this study, the dermal denticles of one particular member of the slow-swimming sharks, Scyliorhinus canicula were characterized and it was found that a significant natural variation in denticle dimensions exists in this species. The degree of denticle surface contamination was quantified on denticles at various locations and it was determined that the degree of contamination of the dorsal surface of denticles varies with the position on the shark body. In addition, we successfully produced synthetic sharkskin samples using the real skin as a template. Testing of the produced synthetic skin in field conditions resulted in significant differences in material attachment on surfaces exhibiting denticles of different dimensions.

  7. The characterization, replication and testing of dermal denticles of Scyliorhinus canicula for physical mechanisms of biofouling prevention.

    Science.gov (United States)

    Sullivan, Timothy; Regan, Fiona

    2011-12-01

    There is a current need to develop novel non-toxic antifouling materials. The mechanisms utilized by marine organisms to prevent fouling of external surfaces are of interest in this regard. Biomimicry of these mechanisms and the ability to transfer the antifouling characteristics of these surfaces to artificial surfaces are a highly attractive prospect to those developing antifouling technologies. In order to achieve this, the mechanisms responsible for any antifouling ability must be elucidated from the study of the natural organism and the critical surface parameters responsible for fouling reduction. Dermal denticles of members of the shark family have been speculated to possess some natural, as yet unidentified antifouling mechanism related to the physical presence of denticles. In this study, the dermal denticles of one particular member of the slow-swimming sharks, Scyliorhinus canicula were characterized and it was found that a significant natural variation in denticle dimensions exists in this species. The degree of denticle surface contamination was quantified on denticles at various locations and it was determined that the degree of contamination of the dorsal surface of denticles varies with the position on the shark body. In addition, we successfully produced synthetic sharkskin samples using the real skin as a template. Testing of the produced synthetic skin in field conditions resulted in significant differences in material attachment on surfaces exhibiting denticles of different dimensions.

  8. The characterization, replication and testing of dermal denticles of Scyliorhinus canicula for physical mechanisms of biofouling prevention

    International Nuclear Information System (INIS)

    Sullivan, Timothy; Regan, Fiona

    2011-01-01

    There is a current need to develop novel non-toxic antifouling materials. The mechanisms utilized by marine organisms to prevent fouling of external surfaces are of interest in this regard. Biomimicry of these mechanisms and the ability to transfer the antifouling characteristics of these surfaces to artificial surfaces are a highly attractive prospect to those developing antifouling technologies. In order to achieve this, the mechanisms responsible for any antifouling ability must be elucidated from the study of the natural organism and the critical surface parameters responsible for fouling reduction. Dermal denticles of members of the shark family have been speculated to possess some natural, as yet unidentified antifouling mechanism related to the physical presence of denticles. In this study, the dermal denticles of one particular member of the slow-swimming sharks, Scyliorhinus canicula were characterized and it was found that a significant natural variation in denticle dimensions exists in this species. The degree of denticle surface contamination was quantified on denticles at various locations and it was determined that the degree of contamination of the dorsal surface of denticles varies with the position on the shark body. In addition, we successfully produced synthetic sharkskin samples using the real skin as a template. Testing of the produced synthetic skin in field conditions resulted in significant differences in material attachment on surfaces exhibiting denticles of different dimensions.

  9. The Physics IQ Test

    Science.gov (United States)

    Berg, Richard

    2003-04-01

    The assembled throngs vote on the outcomes of "brain-teaser" type physics questions that involve elementary physics but may contain some counterintuitive or unexpected result. Following each vote, the students are allowed to discuss the question among each other and a second vote is taken. The question is then answered by performing a demonstration experiment. This procedure is used to encourage students to discuss how the laws of physics are applied to real physical situations and to learn from each other. Demonstrations of this type have been used successfully in a large range of classes at the University of Maryland, and have also been used to pique the interest of pre-college students in taking physics classes.

  10. Biodegradation and Mineralization of Polystyrene by Plastic-Eating Mealworms: Part 1. Chemical and Physical Characterization and Isotopic Tests.

    Science.gov (United States)

    Yang, Yu; Yang, Jun; Wu, Wei-Min; Zhao, Jiao; Song, Yiling; Gao, Longcheng; Yang, Ruifu; Jiang, Lei

    2015-10-20

    Polystyrene (PS) is generally considered to be durable and resistant to biodegradation. Mealworms (the larvae of Tenebrio molitor Linnaeus) from different sources chew and eat Styrofoam, a common PS product. The Styrofoam was efficiently degraded in the larval gut within a retention time of less than 24 h. Fed with Styrofoam as the sole diet, the larvae lived as well as those fed with a normal diet (bran) over a period of 1 month. The analysis of fecula egested from Styrofoam-feeding larvae, using gel permeation chromatography (GPC), solid-state (13)C cross-polarization/magic angle spinning nuclear magnetic resonance (CP/MAS NMR) spectroscopy, and thermogravimetric Fourier transform infrared (TG-FTIR) spectroscopy, substantiated that cleavage/depolymerization of long-chain PS molecules and the formation of depolymerized metabolites occurred in the larval gut. Within a 16 day test period, 47.7% of the ingested Styrofoam carbon was converted into CO2 and the residue (ca. 49.2%) was egested as fecula with a limited fraction incorporated into biomass (ca. 0.5%). Tests with α (13)C- or β (13)C-labeled PS confirmed that the (13)C-labeled PS was mineralized to (13)CO2 and incorporated into lipids. The discovery of the rapid biodegradation of PS in the larval gut reveals a new fate for plastic waste in the environment.

  11. Testing for Classicality of a Physical System

    Science.gov (United States)

    Dorninger, Dietmar; Länger, Helmut

    2013-04-01

    Often quantum logics are algebraically modelled by orthomodular posets. The physical system described by such a quantum logic is classical if and only if the corresponding orthomodular poset is a Boolean algebra. We provide an easy testing procedure for this case. Moreover, we characterize orthomodular posets which are lattices and consider orthomodular posets which admit a full set of states and hence represent so-called spaces of numerical events. This way further test procedures are obtained.

  12. Axiomatic characterization of physical geometry

    International Nuclear Information System (INIS)

    Schmidt, H.J.

    1979-01-01

    This book deals with the foundations of a theory which can be considered as the most ancient part of physics, namely Euclidean geometry. It may be viewed as a partial realization of a program set up by G. Ludwig who suggested to formulate geometry explicity as a theory of possible operations with practically rigid bodies, using as basic concepts 'region', 'inclusion' and 'transport'. After an introduction to the problems, in which we sketch also the historical development, we develop a pre-theory with respect to the geometry with the aim to give an interpretation of the above-mentioned basic geometrical concepts in terms of notions which are closely related to experimental situations. The passage from a pure topological analysis of physical space to the differential geometrical view is made in the next section where we use the prerequisites established in the previous chapter to apply the Tits/Freudenthal solution of the Helmholtz-Lie problem. The main theorem of this book is stated in the last section by a characterization of Euclidean geometry. It turns out that two additional postulates are necessary whose empirical meaning we stress by referring to the axiom of dimension. The book might be of interest to scientist working in the field of axiomatics. Unfamiliar readers will be required to have a sound knowledge of topology and group theory. (HJ) 891 HJ/HJ 892 MB

  13. Digface characterization test plan (remote testing)

    International Nuclear Information System (INIS)

    Croft, K.; Hyde, R.; Allen, S.

    1993-08-01

    The objective of the Digface Characterization (DFC) Remote Testing project is to remotely deploy a sensor head (Mini-Lab) across a digface to determine if it can characterize the contents below the surface. The purpose of this project is to provide a robotics technology that allows removal of workers from hazards, increases speed of operations, and reduces life cycle costs compared to alternate methods and technologies. The Buried Waste Integrated Demonstration (BWID) is funding the demonstration, testing, and evaluation of DFC. This document describes the test plan for the DFC remote deployment demonstration for the BWID. The purposes of the test plan are to establish test parameters so that the demonstration results are deemed useful and usable and perform the demonstration in a safe manner and within all regulatory requirements

  14. Physical sampling for site and waste characterization

    International Nuclear Information System (INIS)

    Bonnough, T.L.

    1994-01-01

    Physical sampling plays a basic role in site and waste characterization program effort. The term ''physical sampling'' used here means collecting tangible, physical samples of soil, water, air, waste streams, or other materials. The industry defines the term ''physical sampling'' broadly to include measurements of physical conditions such as temperature, wind conditions, and pH which are also often taken in a sample collection effort. Most environmental compliance actions are supported by the results of taking, recording, and analyzing physical samples and the measuring of physical conditions taken in association with sample collecting

  15. Geophysical testing of rock and its relationships to physical properties

    Science.gov (United States)

    2011-02-01

    Testing techniques were designed to characterize spatial variability in geotechnical engineering physical parameters of : rock formations. Standard methods using seismic waves, which are routinely used for shallow subsurface : investigation, have lim...

  16. Physical Characterization of Florida International University Simulants

    Energy Technology Data Exchange (ETDEWEB)

    HANSEN, ERICHK.

    2004-08-19

    Florida International University shipped Laponite, clay (bentonite and kaolin blend), and Quality Assurance Requirements Document AZ-101 simulants to the Savannah River Technology Center for physical characterization and to report the results. The objectives of the task were to measure the physical properties of the fluids provided by FIU and to report the results. The physical properties were measured using the approved River Protection Project Waste Treatment Plant characterization procedure [Ref. 1]. This task was conducted in response to the work outlined in CCN066794 [Ref. 2], authored by Gary Smith and William Graves of RPP-WTP.

  17. Physical Penetration Testing: A Whole New Story in Penetration Testing

    NARCIS (Netherlands)

    Dimkov, T.; Pieters, Wolter

    2011-01-01

    Physical penetration testing plays an important role in assuring a company that the security policies are properly enforced and that the security awareness of the employees is on the appropriate level. In physical penetration tests the tester physically enters restricted locations and directly

  18. Physical-Chemical and Mechanical characterization of some cement products in Madagascar by using Technical Analysis X-ray Fluorescence and tests receptions

    International Nuclear Information System (INIS)

    Rasolondraibe, I.P.

    2014-01-01

    The present work is completely realized at the 'Institut National des Sciences et Techniques Nucleaires (INSTN - Madagascar)' and 'Laboratoire National des Travaux Publics et du Batiment (LNTPB)'. Its purpose is to carry out the physico - chemical and mechanical analysis of the cements products present in Madagascar in order to ensure their qualities in case of Building and Publics Works construction safety. The necessary chemical elements in cements are the loss in ignition (LOI), the insoluble residues (RI), the silica (SiO 2 ), the lime (CaO), the alumina (Al 2 O 3 ), the iron oxide (Fe 2 O 3 ), the magnesia (MgO) and the sulfate (SO 3 ). In this work, analytical laboratory in X - Ray fluorescence department of INSTN - Madagascar using the direct excitation X - Ray fluorescence technique outline their research on lime and iron oxide while L.N.T.P.B materials laboratory can make all using test method by gravimetry and titrimetry according to EN 196 - 2. The results of INSTN - Madagascar show that the concentrations of calcium oxide and iron oxide are consistent with the concentration range provided by the laboratory materials L.N.T.P.B respectively equal to 50.00 % - 65.00 % and 1.00 % - 5.00 %. The results between the two laboratories have a - 4.76 % iron oxide maximum relative deviation and 4,77 % calcium oxide maximum relative deviation. Complementary physical and mechanical tests were performed at L.N.T.P.B materials laboratory respectively in accordance with EN 196 - 3 and EN 196 - 1. The used conventional X - ray fluorescence method fulfill the scope of application needed with good correlation less than ± 5 %. [fr

  19. Magnetoelectrostatic thruster physical geometry tests

    Science.gov (United States)

    Ramsey, W. D.

    1981-01-01

    Inert gas tests are conducted with several magnetoelectrostatic containment discharge chamber geometries. The configurations tested include three discharge chamber lengths; three boundary magnet patterns; two different flux density magnet materials; hemispherical and conical shaped thrusters having different surface-to-volume ratios; and two and three grid ion optics. Argon mass utilizations of 60 to 79% are attained at 210 to 280 eV/ion in different test configurations. Short hemi thruster configurations are found to produce 70 to 92% xenon mass utilization at 185 to 220 eV/ion.

  20. Gas characterization system software acceptance test report

    International Nuclear Information System (INIS)

    Vo, C.V.

    1996-01-01

    This document details the results of software acceptance testing of gas characterization systems. The gas characterization systems will be used to monitor the vapor spaces of waste tanks known to contain measurable concentrations of flammable gases

  1. Characterizing the gender gap in introductory physics

    Directory of Open Access Journals (Sweden)

    Lauren E. Kost

    2009-01-01

    Full Text Available Previous research [S. J. Pollock et al., Phys. Rev. ST Phys. Educ. Res. 3, 1 (2007] showed that despite the use of interactive engagement techniques, the gap in performance between males and females on a conceptual learning survey persisted from pretest to post-test at the University of Colorado at Boulder. Such findings were counter to previously published work [M. Lorenzo et al., Am. J. Phys. 74, 118 (2006]. This study begins by identifying a variety of other gender differences. There is a small but significant difference in the course grades of males and females. Males and females have significantly different prior understandings of physics and mathematics. Females are less likely to take high school physics than males, although they are equally likely to take high school calculus. Males and females also differ in their incoming attitudes and beliefs about physics. This collection of background factors is analyzed to determine the extent to which each factor correlates with performance on a conceptual post-test and with gender. Binned by quintiles, we observe that males and females with similar pretest scores do not have significantly different post-test scores (p>0.2. The post-test data are then modeled using two regression models (multiple regression and logistic regression to estimate the gender gap in post-test scores after controlling for these important prior factors. These prior factors account for about 70% of the observed gender gap. The results indicate that the gender gap exists in interactive physics classes at our institution but is largely associated with differences in previous physics and math knowledge and incoming attitudes and beliefs.

  2. Construct Validity of Physical Fitness Tests

    Science.gov (United States)

    2011-02-03

    Medicine and Science in Sports and Exercise , 21, 319-324. *Fleishman, E. A. (1964). The structure and measurement of physical fitness. Englewood Cliffs...sprint and distance runners. Medicine and Science in Sports and Exercise , 19, 56-61. Physical Fitness Test Validity 25 *Tornvall, G. (1963

  3. Effective Teaching Practices during Physical Fitness Testing

    Science.gov (United States)

    Stewart, Amanda; Elliot, Steven; Boyce, B. Ann; Block, Martin E.

    2005-01-01

    Participation in fitness tests is among the most common memories many adults hold of physical education class. If students have a negative attitude towards fitness testing, they may be less likely to assess their own progress once they graduate. These negative attitudes often promote lifestyle choices that support participation in at-risk…

  4. Production test-080, physics testing at D reactor deactivation

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, G.F.

    1967-06-15

    The purpose of this test is to provide a set of experimental data to test a compute code frequently used in nuclear safety analyses and to explore certain experimental techniques which may prove extremely valuable in the future. In addition, some basic physics parameters which will be measured may be used in an assessment of the feasibility of using a deactivated Hanford reactor for space-dependent transient tests.

  5. Tests of the particle physics-physical cosmology interface

    International Nuclear Information System (INIS)

    Schramm, D.N.

    1993-01-01

    Three interrelated interfaces of particle physics and physical cosmology are discussed: (1) inflation and other phase transitions; (2) Big Bang Nucleosynthesis (and also the quark-hadron transition); and (3) structure formation (including dark matter). Recent observations that affect each of these topics are discussed. Topic number 1 is shown to be consistent with the COBE observations but not proven and it may be having problems with some age-expansion data. Topic number 2 has now been well-tested and is an established ''pillar'' of the Big Bang. Topic number 3 is the prime arena of current physical cosmological activity. Experiments to resolve the current exciting, but still ambiguous, situation following the COBE results are discussed

  6. Project Physics Tests 4, Light and Electromagnetism.

    Science.gov (United States)

    Harvard Univ., Cambridge, MA. Harvard Project Physics.

    Test items relating to Project Physics Unit 4 are presented in this booklet. Included are 70 multiple-choice and 22 problem-and-essay questions. Concepts of light and electromagnetism are examined on charges, reflection, electrostatic forces, electric potential, speed of light, electromagnetic waves and radiations, Oersted's and Faraday's work,…

  7. JOHNSON-MATTHEY DIFFUSER CHARACTERIZATION TESTING

    International Nuclear Information System (INIS)

    Foster, P; James Klein, J; Henry Sessions, H; Gregg Morgan, G

    2007-01-01

    A diffuser/permeator commercially fabricated by Johnson-Matthey was purchased for characterization testing at the Savannah River National Laboratory (SRNL). A test system was fabricated to not only feed and bleed flows and pressures, but also permeate pressure for flows up to 20 SLPM

  8. Double tracks test site characterization report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-05-01

    This report presents the results of site characterization activities performed at the Double Tracks Test Site, located on Range 71 North, of the Nellis Air Force Range (NAFR) in southern Nevada. Site characterization activities included reviewing historical data from the Double Tracks experiment, previous site investigation efforts, and recent site characterization data. The most recent site characterization activities were conducted in support of an interim corrective action to remediate the Double Tracks Test Site to an acceptable risk to human health and the environment. Site characterization was performed using a phased approach. First, previously collected data and historical records sere compiled and reviewed. Generalized scopes of work were then prepared to fill known data gaps. Field activities were conducted and the collected data were then reviewed to determine whether data gaps were filled and whether other areas needed to be investigated. Additional field efforts were then conducted, as required, to adequately characterize the site. Characterization of the Double Tracks Test Site was conducted in accordance with the US Department of Energy`s (DOE) Streamlined Approach for Environmental Restoration (SAFER).

  9. Physical Readiness Testing of Surface Warfare Officers

    Science.gov (United States)

    1991-06-01

    NA% I PHISICAL READIiESS TEST (PRT QUEST1OthAIRE I. hE ARE CONDUCTI NG THESIS RESEAR H 0N HO- ELL THE PRT SUPPORT5 TNE R 0 T i E 0F St RF AC E ’ARAR...AD-A245 519 NAVAL POSTGRADUATE SCHOOL Monterey, California DTIC CTE.EC a% FEB071992 CI THESIS Physical Readiness Testing of Surface Warfare Officers...READINESS TESTING OF SURFACE WARFARE OFFICERS 12. PERSONAL AUTHOR(S) Hatch, William D. II and Swinney, Lori D. 13a. TYPE OF REPORT 13b. TIME COVERED 14

  10. Characterizing the epistemological development of physics majors

    Directory of Open Access Journals (Sweden)

    Elizabeth Gire

    2009-02-01

    Full Text Available Students in introductory physics courses are likely to have views about physics that differ from those of experts. However, students who continue to study physics eventually become experts themselves. Presumably these students either possess or develop more expertlike views. To investigate this process, the views of introductory physics students majoring in physics are compared with the views of introductory physics students majoring in engineering. In addition, the views of physics majors are assessed at various stages of degree progress. The Colorado learning attitudes about science survey is used to evaluate students’ views about physics, and students’ overall survey scores and responses to individual survey items are analyzed. Beginning physics majors are significantly more expertlike than nonmajors in introductory physics courses, and this high level of sophistication is consistent for most of undergraduate study.

  11. Johnson-Matthey diffuser characterization testing

    International Nuclear Information System (INIS)

    Foster, P. J.; Klein, J. E.; Sessions, H. T.; Morgan, G. A.

    2008-01-01

    A diffuser/permeator commercially fabricated by Johnson-Matthey was purchased for characterization testing at the Savannah River National Laboratory (SRNL). A test system was fabricated to test not only feed and bleed flows and pressures, but also permeate pressure for flows up to 20 sLPM. The tests described in this paper consider the effect of various inert gas types, feed gas compositions, methods for temperature control, and varying tube pressure on permeation of H 2 through the Pd/Ag tubes. (authors)

  12. Physical characterization of steel and stainless steel metal powders

    International Nuclear Information System (INIS)

    Lavilla, A.O.; Lucchesi, C.G.; Sandin, O.O.

    1991-01-01

    A methodology has been developed for the physical characterization of steel powders (obtained by atomization) for later sintering and for the construction of porous sheets and filtrating tubes, capable of operating at temperatures between 600 deg C and 800 deg C in corrosive atmospheres. This methodology was based on the equipment and methods used for the physical characterization of uranium oxide powders. (Author) [es

  13. Testing fundamental physics with gravitational waves

    CERN Multimedia

    CERN. Geneva

    2017-01-01

    The landmark detection of gravitational waves (GWs) has opened a new era in physics, giving access to the hitherto unexplored strong-gravity regime, where spacetime curvature is extreme and the relevant speed is close to the speed of light. In parallel to its countless astrophysical applications, this discovery can have also important implications for fundamental physics. In this context, I will discuss some outstanding, cross-cutting problems that can be finally investigated in the GW era: the nature of black holes and of spacetime singularities, the limits of classical gravity, the existence of extra light fields, and the effects of dark matter near compact objects. Future GW measurements will provide unparalleled tests of quantum-gravity effects at the horizon scale, exotic compact objects, ultralight dark matter, and of general relativity in the strong-field regime.

  14. Refined Characterization of Student Perspectives on Quantum Physics

    Science.gov (United States)

    Baily, Charles; Finkelstein, Noah D.

    2010-01-01

    The perspectives of introductory classical physics students can often negatively influence how those students later interpret quantum phenomena when taking an introductory course in modern physics. A detailed exploration of student perspectives on the interpretation of quantum physics is needed, both to characterize student understanding of…

  15. 49 CFR 179.500-7 - Physical tests.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Physical tests. 179.500-7 Section 179.500-7...-7 Physical tests. (a) Physical tests shall be made on two test specimens 0.505 inch in diameter... tank. These test specimen ring sections or prolongations shall be heat treated, with the necked-down...

  16. Historical hydronuclear testing: Characterization and remediation technologies

    Energy Technology Data Exchange (ETDEWEB)

    Shaulis, L.; Wilson, G.; Jacobson, R.

    1997-09-01

    This report examines the most current literature and information available on characterization and remediation technologies that could be used on the Nevada Test Site (NTS) historical hydronuclear test areas. Historical hydronuclear tests use high explosives and a small amount of plutonium. The explosion scatters plutonium within a contained subsurface environment. There is currently a need to characterize these test areas to determine the spatial extent of plutonium in the subsurface and whether geohydrologic processes are transporting the plutonium away from the event site. Three technologies were identified to assist in the characterization of the sites. These technologies are the Pipe Explorer{trademark}, cone penetrometer, and drilling. If the characterization results indicate that remediation is needed, three remediation technologies were identified that should be appropriate, namely: capping or sealing the surface, in situ grouting, and in situ vitrification. Capping the surface would prevent vertical infiltration of water into the soil column, but would not restrict lateral movement of vadose zone water. Both the in situ grouting and vitrification techniques would attempt to immobilize the radioactive contaminants to restrict or prevent leaching of the radioactive contaminants into the groundwater. In situ grouting uses penetrometers or boreholes to inject the soil below the contaminant zone with low permeability grout. In situ vitrification melts the soil containing contaminants into a solid block. This technique would provide a significantly longer contaminant immobilization, but some research and development would be required to re-engineer existing systems for use at deep soil depths. Currently, equipment can only handle shallow depth vitrification. After existing documentation on the historical hydronuclear tests have been reviewed and the sites have been visited, more specific recommendations will be made.

  17. Historical hydronuclear testing: Characterization and remediation technologies

    International Nuclear Information System (INIS)

    Shaulis, L.; Wilson, G.; Jacobson, R.

    1997-09-01

    This report examines the most current literature and information available on characterization and remediation technologies that could be used on the Nevada Test Site (NTS) historical hydronuclear test areas. Historical hydronuclear tests use high explosives and a small amount of plutonium. The explosion scatters plutonium within a contained subsurface environment. There is currently a need to characterize these test areas to determine the spatial extent of plutonium in the subsurface and whether geohydrologic processes are transporting the plutonium away from the event site. Three technologies were identified to assist in the characterization of the sites. These technologies are the Pipe Explorer trademark, cone penetrometer, and drilling. If the characterization results indicate that remediation is needed, three remediation technologies were identified that should be appropriate, namely: capping or sealing the surface, in situ grouting, and in situ vitrification. Capping the surface would prevent vertical infiltration of water into the soil column, but would not restrict lateral movement of vadose zone water. Both the in situ grouting and vitrification techniques would attempt to immobilize the radioactive contaminants to restrict or prevent leaching of the radioactive contaminants into the groundwater. In situ grouting uses penetrometers or boreholes to inject the soil below the contaminant zone with low permeability grout. In situ vitrification melts the soil containing contaminants into a solid block. This technique would provide a significantly longer contaminant immobilization, but some research and development would be required to re-engineer existing systems for use at deep soil depths. Currently, equipment can only handle shallow depth vitrification. After existing documentation on the historical hydronuclear tests have been reviewed and the sites have been visited, more specific recommendations will be made

  18. GD SDR Automatic Gain Control Characterization Testing

    Science.gov (United States)

    Nappier, Jennifer M.; Briones, Janette C.

    2013-01-01

    The General Dynamics (GD) S-Band software defined radio (SDR) in the Space Communications and Navigation (SCAN) Testbed on the International Space Station (ISS) will provide experimenters an opportunity to develop and demonstrate experimental waveforms in space. The GD SDR platform and initial waveform were characterized on the ground before launch and the data will be compared to the data that will be collected during on-orbit operations. A desired function of the SDR is to estimate the received signal to noise ratio (SNR), which would enable experimenters to better determine on-orbit link conditions. The GD SDR does not have an SNR estimator, but it does have an analog and a digital automatic gain control (AGC). The AGCs can be used to estimate the SDR input power which can be converted into a SNR. Tests were conducted to characterize the AGC response to changes in SDR input power and temperature. This purpose of this paper is to describe the tests that were conducted, discuss the results showi ng how the AGCs relate to the SDR input power, and provide recommendations for AGC testing and characterization.

  19. Alpha Particle Physics Experiments in the Tokamak Fusion Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Budny, R.V.; Darrow, D.S.; Medley, S.S.; Nazikian, R.; Zweben, S.J.; et al.

    1998-12-14

    Alpha particle physics experiments were done on the Tokamak Fusion Test Reactor (TFTR) during its deuterium-tritium (DT) run from 1993-1997. These experiments utilized several new alpha particle diagnostics and hundreds of DT discharges to characterize the alpha particle confinement and wave-particle interactions. In general, the results from the alpha particle diagnostics agreed with the classical single-particle confinement model in magnetohydrodynamic (MHD) quiescent discharges. Also, the observed alpha particle interactions with sawteeth, toroidal Alfvén eigenmodes (TAE), and ion cyclotron resonant frequency (ICRF) waves were roughly consistent with theoretical modeling. This paper reviews what was learned and identifies what remains to be understood.

  20. Synthesis, physical characterization, antibacterial activity and ...

    African Journals Online (AJOL)

    Some five-coordinated cobalt(III) complexes were synthesized and characterized using elemental analysis, 1H NMR and IR spectra. The formation constants and the thermodynamic parameters were measured spectrophotometrically for the 1:1 adduct formation of [Co(Chel)(PBu3)]ClO4.H2O where Chel = cd3OMesalen, ...

  1. Report on COTECH test procedure and characterization techniques

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul

    .Characterization techniques and test procedure requirements for innovative self-ligating dental brackets (EO) Section 5.Characterization techniques and test procedure requirements for smart diagnostic chips comprising a microfluidic channel system (GBO) Section 6.Characterization techniques and test procedure...... requirements for multifunctional integrated lighting rear lamp for cars (CRP) Section 7.Characterization techniques and test procedure requirements for micro-fresnel lenses for cell phone flash lights (HEPTAGON) Section 8.Characterization techniques and test procedure requirements for 5 Pin Ric Connector...

  2. Physical and Electrical Characterization of Polymer Aluminum Capacitors

    Science.gov (United States)

    Liu, David; Sampson, Michael J.

    2010-01-01

    Polymer aluminum capacitors from several manufacturers with various combinations of capacitance, rated voltage, and ESR values were physically examined and electrically characterized. The physical construction analysis of the capacitors revealed three different capacitor structures, i.e., traditional wound, stacked, and laminated. Electrical characterization results of polymer aluminum capacitors are reported for frequency-domain dielectric response at various temperatures, surge breakdown voltage, and other dielectric properties. The structure-property relations in polymer aluminum capacitors are discussed.

  3. Physical and Electrical Characterization of Aluminum Polymer Capacitors

    Science.gov (United States)

    Liu, David; Sampson, Michael J.

    2010-01-01

    Polymer aluminum capacitors from several manufacturers with various combinations of capacitance, rated voltage, and ESR values were physically examined and electrically characterized. The physical construction analysis of the capacitors revealed three different capacitor structures, i.e., traditional wound, stacked, and laminated. Electrical characterization results of polymer aluminum capacitors are reported for frequency-domain dielectric response at various temperatures, surge breakdown voltage, and other dielectric properties. The structure-property relations in polymer aluminum capacitors are discussed.

  4. Characterization methods for ultrasonic test systems

    International Nuclear Information System (INIS)

    Busse, L.J.; Becker, F.L.; Bowey, R.E.; Doctor, S.R.; Gribble, R.P.; Posakony, G.J.

    1982-07-01

    Methods for the characterization of ultrasonic transducers (search units) and instruments are presented. The instrument system is considered as three separate components consisting of a transducer, a receiver-display, and a pulser. The operation of each component is assessed independently. The methods presented were chosen because they provide the greatest amount of information about component operation and were not chosen based upon such conditions as cost, ease of operation, field implementation, etc. The results of evaluating a number of commercially available ultrasonic test instruments are presented

  5. Data on the physical characterization of oil in water emulsions

    Directory of Open Access Journals (Sweden)

    Aldana L. Zalazar

    2016-12-01

    Full Text Available This article contains experimental data and images for the physical characterization of oil in water emulsions. Mentioned data are related to the research article “Effect of stabilizers, oil level and structure on the growth of Zygosaccharomyces bailii and on physical stability of model systems simulating acid sauces” (A.L. Zalazar, M.F. Gliemmo, C.A. Campos, 2016 [1]. Physical characterization of emulsions was performed through the evaluation of Span and Specific Surface Area (SSA determined by light scattering using a Mastersizer. Furthermore, microscopy images were recorded by confocal scanning laser microscopy (CSLM. The latter are presented to collaborate in the analysis of emulsion microstructure.

  6. Input characterization of a shock test strructure.

    Energy Technology Data Exchange (ETDEWEB)

    Hylok, J. E. (Jeffrey E.); Groethe, M. A.; Maupin, R. D. (Ryan D.)

    2004-01-01

    Often in experimental work, measuring input forces and pressures is a difficult and sometimes impossible task. For one particular shock test article, its input sensitivity required a detailed measurement of the pressure input. This paper discusses the use of a surrogate mass mock test article to measure spatial and temporal variations of the shock input within and between experiments. Also discussed will be the challenges and solutions in making some of the high speed transient measurements. The current input characterization work appears as part of the second phase in an extensive model validation project. During the first phase, the system under analysis displayed sensitivities to the shock input's qualitative and quantitative (magnitude) characteristics. However, multiple shortcomings existed in the characterization of the input. First, the experimental measurements of the input were made on a significantly simplified structure only, and the spatial fidelity of the measurements was minimal. Second, the sensors used for the pressure measurement contained known errors that could not be fully quantified. Finally, the measurements examined only one input pressure path (from contact with the energetic material). Airblast levels from the energetic materials were unknown. The result was a large discrepancy between the energy content in the analysis and experiments.

  7. Thermodynamics principles characterizing physical and chemical processes

    CERN Document Server

    Honig, Jurgen M

    1999-01-01

    This book provides a concise overview of thermodynamics, and is written in a manner which makes the difficult subject matter understandable. Thermodynamics is systematic in its presentation and covers many subjects that are generally not dealt with in competing books such as: Carathéodory''s approach to the Second Law, the general theory of phase transitions, the origin of phase diagrams, the treatment of matter subjected to a variety of external fields, and the subject of irreversible thermodynamics.The book provides a first-principles, postulational, self-contained description of physical and chemical processes. Designed both as a textbook and as a monograph, the book stresses the fundamental principles, the logical development of the subject matter, and the applications in a variety of disciplines. This revised edition is based on teaching experience in the classroom, and incorporates many exercises in varying degrees of sophistication. The stress laid on a didactic, logical presentation, and on the relat...

  8. Physical Characterization of Clostridium Botulinum Neurotoxin Genes

    Science.gov (United States)

    1993-10-01

    modern food -preserving processes in Western countries has made 1 outbreaks of botulism extremely rare. The frequent use of C.botulinum as a test...organism in the food industry, and the growing use of the toxin by neurobiochemists, has, however, led to the development of human vaccines. The...390v 400v DOTE [• - F -TK--VQ -- 0Q ---YI G Q KM YLFKL NS N - S - N I G NF N K 383 DOTFIFT ED L AINIK FIKIV C RINIT YIF I K MCF LVPIN L L D DDIDII YIT

  9. Intrapixel response test system for multispectral characterization

    Science.gov (United States)

    Lind, Thomas A.; Reich, Robert K.; McGonagle, William H.; Kosicki, Bernard B.

    1999-04-01

    We report on the design of a system used to measure the multispectral intrapixel response of imaging sensor arrays. An Airy disk spot size of approximately 4 micrometers has been achieved for wavelength bands that extend from the visible blue to near IR. The automated system does rapid intrapixel row and/or column spatial mapping of individual pixels as well as rastered 2D spatial scans over multi-pixel girds. Commercially available equipment including a photometric eyepiece, a reflective objects, programmable pushers, and light-emitting diodes are utilized in the system. Scanned results using the system are presented for both front- and back-illuminating charge-coupled device imagers. The intrapixel response of a front-illuminated device shows good correlation with the physical cross section of the devices tested.

  10. Developing Effective Physical Fitness Testing Standards for Pre Service Physical Educators

    Science.gov (United States)

    Hill, Kory; Thornburg, Roland

    2016-01-01

    Physical educators are often held to a higher standard of physical fitness. The ability to effectively convey the importance of physical fitness may depend upon the ability to appear physically fit. The ability to perform at a minimal level of proficiency on fitness tests was deemed important by the faculty of one physical education teacher…

  11. Fitness Testing in Physical Education--A Misdirected Effort in Promoting Healthy Lifestyles and Physical Activity?

    Science.gov (United States)

    Cale, Lorraine; Harris, Jo

    2009-01-01

    Background: Physical fitness testing is commonplace within schools and the physical education (PE) curriculum, with advocates claiming one of the key purposes of testing to be the promotion of healthy lifestyles and physical activity. Despite this, much controversy has surrounded the fitness testing of young people. Purpose: This paper draws on…

  12. Physical characterization of the Skua fast burst assembly

    International Nuclear Information System (INIS)

    Paternoster, R.; Bounds, J.; Sanchez, R.; Miko, D.

    1994-01-01

    In this paper we discuss the system design and ongoing efforts to characterize the machine physics and operating properties of the Skua fast burst assembly. The machine is currently operating up to prompt critical while we await approval for super-prompt burst operations. Efforts have centered on characterizing neutron kinetic properties, comparing calculated and measured temperature coefficients and power distributions, improving the burst reproducibility, examining the site-wide dose characteristics, and fitting the machine with cooling and filtration systems

  13. Teacher testing and implications for physical education

    OpenAIRE

    O'Sullivan, Mary; Tannehill, Deborah

    1990-01-01

    peer-reviewed There has been a dramatic increase in teacher testing in the last decade. State and national attention to this issue is evidenced by the amount of literature devoted to assessment in general and teacher testing in particular. An invitational conference was held last fall by the Educational Testing Service (ETS) to provide a forum for clarifying issues regarding uses of standardized tests in American education in general and teacher testing in particular. Flippo...

  14. Two methodologies for physical penetration testing using social engineering

    NARCIS (Netherlands)

    Dimkov, T.; van Cleeff, A.; Pieters, Wolter; Hartel, Pieter H.

    2010-01-01

    Penetration tests on IT systems are sometimes coupled with physical penetration tests and social engineering. In physical penetration tests where social engineering is allowed, the penetration tester directly interacts with the employees. These interactions are usually based on deception and if not

  15. Startup physics tests at Temelin NPP, Unit 1

    International Nuclear Information System (INIS)

    Sedlacek, M.; Minarcin, M.; Toth, L.; Elko, M.; Hascik, R.

    2002-01-01

    The objective, scope and proceedings of the physics tests of Temelin NPP, Unit 1 physical commissioning are given in this paper. Furthermore, some results of selected physics tests are presented: reactor initial criticality test, determination of reactor power range for physics testing, measurement of control rod cluster assembly group no. 10 reactivity worth in case of limitation system LS(a) actuation, control rod cluster assembly system reactivity worth measurement with single rod cluster assembly of greatest reactivity worth stuck in fully withdrawn position, measurement of differential reactivity worth of control rod cluster assembly group no. 9, boron 'endpoint' determination and measurement of power reactivity coefficient (Authors)

  16. Characterization of Physic nut (Jatropha curcas L.) shells

    NARCIS (Netherlands)

    Wever, Diego; Heeres, H. J.; Broekhuis, Antonius A.

    The characterization of Physic nut shells was done using the wet chemical analysis of wood components. The obtained fractions were analyzed using IR, NMR, GPC, ICP and MALDI-TOF mass spectroscopy. TGA was used to determine the fixed carbon (+ash) and water content of the shells. The results of wet

  17. Physical and electrical characterization of reduced graphene oxide ...

    Indian Academy of Sciences (India)

    2, April 2016, pp. 543–550. c Indian Academy of Sciences. Physical and electrical characterization of reduced graphene oxide synthesized adopting green route. TAPAS K GHOSH1,2, SHIRSHENDU GOPE1, DIPAK RANA3, INDRANIL ROY1,. GUNJAN SARKAR1, SOURAV SADHUKHAN1, AMARTYA BHATTACHARYA1,.

  18. Physical property characterization of 183-H Basin sludge

    International Nuclear Information System (INIS)

    Biyani, R.K.; Delegard, C.H.

    1995-01-01

    This document describes the characterization of 183-H Basin sludge physical properties, e.g. bulk density of sludge and absorbent, and determination of free liquids. Calcination of crucible-size samples of sludge was also done and the resulting 'loss-on-ignition' was compared to the theoretical weight loss based on sludge analysis obtained from Weston Labs

  19. ICHPER-SD Asia Youth Health Related Physical Fitness Test.

    Science.gov (United States)

    Journal of the International Council for Health, Physical Education, Recreation, Sport, and Dance, 1994

    1994-01-01

    Presents necessary information for administering the ICHPER-SD Asia Youth Health Related Physical Fitness Test, including descriptions of and scoring for each test item, needed equipment, notes, and suggested preparations for test leaders. The test includes the endurance run, situps in 60 seconds, pullups, sit and reach test, and skinfold…

  20. Destructive Physical Analysis of Flight- and Ground-Tested Sodium-Sulfur Cells

    Science.gov (United States)

    Wasz, Margot L.; Carter, Boyd J.; Donet, Charles M.; Baldwin, Richard S.

    1999-01-01

    Destructive physical analysis (DPA) was used to study the effects of microgravity on the sulfur electrode in sodium-sulfur cells. The cells examined in this work were provided by the Air Force Research Laboratory (AFRL) from their program on sodium-sulfur technology. The Naval Research Laboratory (NRL) provided electrical characterization of the flight-tested and ground-tested cells.

  1. Effects of Vigorous Intensity Physical Activity on Mathematics Test Performance

    Science.gov (United States)

    Phillips, David S.; Hannon, James C.; Castelli, Darla M.

    2015-01-01

    The effect of an acute bout of physical activity on academic performance in school-based settings is under researched. The purpose of this study was to examine associations between a single, vigorous (70-85%) bout of physical activity completed during physical education on standardized mathematics test performance among 72, eighth grade students…

  2. Characterizing, modeling, and addressing gender disparities in introductory college physics

    Science.gov (United States)

    Kost-Smith, Lauren Elizabeth

    2011-12-01

    The underrepresentation and underperformance of females in physics has been well documented and has long concerned policy-makers, educators, and the physics community. In this thesis, we focus on gender disparities in the first- and second-semester introductory, calculus-based physics courses at the University of Colorado. Success in these courses is critical for future study and careers in physics (and other sciences). Using data gathered from roughly 10,000 undergraduate students, we identify and model gender differences in the introductory physics courses in three areas: student performance, retention, and psychological factors. We observe gender differences on several measures in the introductory physics courses: females are less likely to take a high school physics course than males and have lower standardized mathematics test scores; males outscore females on both pre- and post-course conceptual physics surveys and in-class exams; and males have more expert-like attitudes and beliefs about physics than females. These background differences of males and females account for 60% to 70% of the gender gap that we observe on a post-course survey of conceptual physics understanding. In analyzing underlying psychological factors of learning, we find that female students report lower self-confidence related to succeeding in the introductory courses (self-efficacy) and are less likely to report seeing themselves as a "physics person". Students' self-efficacy beliefs are significant predictors of their performance, even when measures of physics and mathematics background are controlled, and account for an additional 10% of the gender gap. Informed by results from these studies, we implemented and tested a psychological, self-affirmation intervention aimed at enhancing female students' performance in Physics 1. Self-affirmation reduced the gender gap in performance on both in-class exams and the post-course conceptual physics survey. Further, the benefit of the self

  3. ACL injury: How do the physical examination tests compare?

    Science.gov (United States)

    Koster, Christiaan H; Harmsen, Annelieke Mk; Lichtenberg, Miranda C; Bloemers, Frank W

    2018-03-01

    Three physical examination tests are most commonly used to evaluate cruciate ligament injury. The best known and most frequently used technique is the anterior drawer test. The other 2 tests, the Lachman test and the pivot shift test, are more difficult to perform and are used less often, especially by physicians untrained in their use. In addition, there is a relatively new diagnostic test: the lever sign test. The aim of our article is to provide a short, clinically relevant overview of the literature and to assess the diagnostic value of physical examination for the primary care physician.

  4. Fabrication and characterization of absorber pellets for FFTF irradiation testing

    International Nuclear Information System (INIS)

    Wilson, C.N.; Hollenberg, G.W.

    1981-01-01

    Methods used for characterization of B 4 C powder and fabricated pellets are summarized. Fabrication techniques used at HEDL for absorber test pellets are reviewed and selected powder and pellet characterization data are presented

  5. Mathematical Reasoning Requirements in Swedish National Physics Tests

    Science.gov (United States)

    Johansson, Helena

    2016-01-01

    This paper focuses on one aspect of mathematical competence, namely mathematical reasoning, and how this competency influences students' knowing of physics. This influence was studied by analysing the mathematical reasoning requirements upper secondary students meet when solving tasks in national physics tests. National tests are constructed to…

  6. Statewide Physical Fitness Testing: Perspectives from the Gym

    Science.gov (United States)

    Martin, Scott B.; Ede, Alison; Morrow, James R., Jr.; Jackson, Allen W.

    2010-01-01

    This paper provides observations of physical fitness testing in Texas schools and physical education teachers' insights about large-scale testing using the FITNESSGRAM[R] assessment (Cooper Institute, 2007) as mandated by Texas Senate Bill 530. In the first study, undergraduate and graduate students who were trained to observe and assess student…

  7. Antihydrogen for precision tests in physics

    CERN Document Server

    Charlton, M; Jørgensen, L V; Madsen, N; van der Werf, D P

    2008-01-01

    The creation of atoms of antihydrogen under controlled conditions has opened up a new era in physics with antimatter. We describe the experimental realisation of low energy antihydrogen, via the mixing of carefully prepared clouds of positrons and antiprotons, and some of the progress that has been made in the last few years in characterising properties of the nascent anti-atoms. Ongoing efforts aimed at trapping the anti-atoms in magnetic field minima are discussed. Some of the motivations for undertaking experiments with antihydrogen are presented.

  8. Mössbauer and XRD characterization of the effect of heat treatment and the tribological test on the physical and mechanical properties of a Fe-Mn-Al-C alloy

    Science.gov (United States)

    Ramos, J.; Piamba, J. F.; Sanchez, H.; Pérez Alcazar, G. A.

    2017-11-01

    In this study, a Fe-29.0Mn-6.0Al-0.9C-1.8Mo-1.6Si-0.4Cu (Wt. %) alloy was prepared in an induction furnace. The as-cast sample was submitted to homogenization at 1050 °C over 8 hours, which was followed by quenching, and an aging heat treatment at 500 °C for 12 h. Wear tests were performed by using a Pin on Disk Tribometer (ASTM G99) at room temperature to evaluate the mass loss. Optical Microscopy, X-Ray Diffraction, and Transmission Mossbauer Spectroscopy were used to characterize the microstructure and structural properties of the samples. The obtained microstructure of the heat-treated samples was of the austenitic type, and their XRD patterns were refined with the lines of the austenite, martensite, galaxite, and FeO structures. Mössbauer spectra of powders, obtained from the surface of the samples, showed the presence of a broad doublet, which corresponded to the disordered austenite; and a small hyperfine magnetic field distribution associated with the disordered and ferromagnetic martensite. After the tribology test, the surface of the sample was examined, and it was obderved that the austenite, martensite, and galaxite phases were present. The martensite quantity increased and, those of galaxite and austenite decreased, but that of austenite appeared to have larger lattice parameter. The decrease in the galaxite content was a direct consequence of the wear test, which removed matter from the sample surface. The appearance of additional martensite was due to the transformation of the austenite by mechanical work. The additional presence of a new austenite with a bigger lattice parameter and of the Fe oxide was the consequence of the heating process of the sample during the tribological test. The Mossbauer spectrum of this sample confirms the increase of the martensite content. The mechanical properties increased with the heat treatment.

  9. Characterization Testing - A Predictive Maintenance Advantage

    National Research Council Canada - National Science Library

    Randolph, Russ

    1998-01-01

    Knowing that a traditional time directed preventive maintenance program is limited in its flexibility and effectiveness, the CHAR 921 characterization system software was developed as an open architecture design...

  10. Atomic physics tests of quantum electrodynamics

    International Nuclear Information System (INIS)

    Mohr, P.J.

    1976-08-01

    The tests of quantum electrodynamics derived from bound systems and the free electron and muon magnetic moments are reviewed. The emphasis is on the areas in which recent developments in theory or experiment have taken place. Also determinations of the fine structure constant from the Josephson effect and the fine structure of helium are discussed

  11. Novel instrument for characterizing comprehensive physical properties under multi-mechanical loads and multi-physical field coupling conditions

    Science.gov (United States)

    Liu, Changyi; Zhao, Hongwei; Ma, Zhichao; Qiao, Yuansen; Hong, Kun; Ren, Zhuang; Zhang, Jianhai; Pei, Yongmao; Ren, Luquan

    2018-02-01

    Functional materials represented by ferromagnetics and ferroelectrics are widely used in advanced sensor and precision actuation due to their special characterization under coupling interactions of complex loads and external physical fields. However, the conventional devices for material characterization can only provide a limited type of loads and physical fields and cannot simulate the actual service conditions of materials. A multi-field coupling instrument for characterization has been designed and implemented to overcome this barrier and measure the comprehensive physical properties under complex service conditions. The testing forms include tension, compression, bending, torsion, and fatigue in mechanical loads, as well as different external physical fields, including electric, magnetic, and thermal fields. In order to offer a variety of information to reveal mechanical damage or deformation forms, a series of measurement methods at the microscale are integrated with the instrument including an indentation unit and in situ microimaging module. Finally, several coupling experiments which cover all the loading and measurement functions of the instrument have been implemented. The results illustrate the functions and characteristics of the instrument and then reveal the variety in mechanical and electromagnetic properties of the piezoelectric transducer ceramic, TbDyFe alloy, and carbon fiber reinforced polymer under coupling conditions.

  12. ASTM test methods for composite characterization and evaluation

    Science.gov (United States)

    Masters, John E.

    1994-01-01

    A discussion of the American Society for Testing and Materials is given. Under the topic of composite materials characterization and evaluation, general industry practice and test methods for textile composites are presented.

  13. Kansas Adapted/Special Physical Education Test Manual. Health Related Fitness and Psychomotor Testing.

    Science.gov (United States)

    Johnson, Robert E.; Lavay, Barry

    This manual was developed to address the need for health-related physical fitness testing of children with special needs. The first section defines the components of health-related physical fitness which consist of: (1)abdominal strength and endurance measured by a sit-up test; (2) flexibility, measured by a sit and reach test; (3) upper body…

  14. Physical Activity and Cervical Cancer Testing among American Indian Women

    Science.gov (United States)

    Muus, Kyle J.; Baker-Demaray, Twyla B.; Bogart, T. Andy; Duncan, Glen E.; Jacobsen, Clemma; Buchwald, Dedra S.; Henderson, Jeffrey A.

    2012-01-01

    Purpose: Studies have shown that women who engage in high levels of physical activity have higher rates of cancer screening, including Papanicalaou (Pap) tests. Because American Indian (AI) women are at high risk for cervical cancer morbidity and mortality, we examined Pap screening prevalence and assessed whether physical activity was associated…

  15. Reliability and Validity Testing of the Physical Resilience Measure

    Science.gov (United States)

    Resnick, Barbara; Galik, Elizabeth; Dorsey, Susan; Scheve, Ann; Gutkin, Susan

    2011-01-01

    Objective: The purpose of this study was to test reliability and validity of the Physical Resilience Scale. Methods: A single-group repeated measure design was used and 130 older adults from three different housing sites participated. Participants completed the Physical Resilience Scale, Hardy-Gill Resilience Scale, 14-item Resilience Scale,…

  16. Physical and chemical characterization of bioaerosols - Implications for nucleation processes

    Science.gov (United States)

    Ariya, P. A.; Sun, J.; Eltouny, N. A.; Hudson, E. D.; Hayes, C. T.; Kos, G.

    The importance of organic compounds in the oxidative capacity of the atmosphere, and as cloud condensation and ice-forming nuclei, has been recognized for several decades. Organic compounds comprise a significant fraction of the suspended matter mass, leading to local (e.g. toxicity, health hazards) and global (e.g. climate change) impacts. The state of knowledge of the physical chemistry of organic aerosols has increased during the last few decades. However, due to their complex chemistry and the multifaceted processes in which they are involved, the importance of organic aerosols, particularly bioaerosols, in driving physical and chemical atmospheric processes is still very uncertain and poorly understood. Factors such as solubility, surface tension, chemical impurities, volatility, morphology, contact angle, deliquescence, wettability, and the oxidation process are pivotal in the understanding of the activation processes of cloud droplets, and their chemical structures, solubilities and even the molecular configuration of the microbial outer membrane, all impact ice and cloud nucleation processes in the atmosphere. The aim of this review paper is to assess the current state of knowledge regarding chemical and physical characterization of bioaerosols with a focus on those properties important in nucleation processes. We herein discuss the potential importance (or lack thereof) of physical and chemical properties of bioaerosols and illustrate how the knowledge of these properties can be employed to study nucleation processes using a modeling exercise. We also outline a list of major uncertainties due to a lack of understanding of the processes involved or lack of available data. We will also discuss key issues of atmospheric significance deserving future physical chemistry research in the fields of bioaerosol characterization and microphysics, as well as bioaerosol modeling. These fundamental questions are to be addressed prior to any definite conclusions on the

  17. Radball Technology Testing For Hot Cell Characterization

    International Nuclear Information System (INIS)

    Farfan, E.; Jannik, T.

    2010-01-01

    Operations at various U.S. Department of Energy sites have resulted in substantial radiological contamination of tools, equipment, and facilities. It is essential to use remote technologies for characterization and decommissioning to keep worker exposures as low as reasonably achievable in these highly contaminated environments. A significant initial step in planning and implementing D and D of contaminated facilities involves the development of an accurate assessment of the radiological, chemical, and structural conditions inside of the facilities. Collected information describing facility conditions using remote technologies could reduce the conservatism associated with planning initial worker entry (and associated cost).

  18. Maximum physical capacity testing in cancer patients undergoing chemotherapy

    DEFF Research Database (Denmark)

    Knutsen, L.; Quist, M; Midtgaard, J

    2006-01-01

    BACKGROUND: Over the past few years there has been a growing interest in the field of physical exercise in rehabilitation of cancer patients, leading to requirements for objective maximum physical capacity measurement (maximum oxygen uptake (VO(2max)) and one-repetition maximum (1RM)) to determine...... in performing maximum physical capacity tests as these motivated them through self-perceived competitiveness and set a standard that served to encourage peak performance. CONCLUSION: The positive attitudes in this sample towards maximum physical capacity open the possibility of introducing physical testing...... early in the treatment process. However, the patients were self-referred and thus highly motivated and as such are not necessarily representative of the whole population of cancer patients treated with chemotherapy....

  19. Physical and Radiation Characterizations on New Thermoluminescence Dosemeter (TLD) Material

    International Nuclear Information System (INIS)

    Wan Saffiey Wan Abdullah; Nadira Kamarudin; Megat Harun Al Rashid; Mohd Taufik Dolah; Ishak Mansor; Hafzaliza Erny Zainal Abidin; Nurazila Mat Zali; Norlina Ab Aziz; Nurhaslinda Ee Abdullah

    2009-01-01

    Full text: A new TLD material for ionizing radiation measurement has been developed in Malaysian Nuclear Agency by using LiF and Mg as dopant. Wet precipitation techniques were used to produce and doped the LiF powder with 0.3 mol % of Mg. Physical characterization have been done by using various techniques. XRD was used to determine the crystallinity of the powder produce. The micrograph of the green and sintered powder were studied using SEM while the size of the powder produced were monitored using Particle Size Analyzer. Part of powder was pelleted to chips by using special mold and hydraulic pressing machine. The powder and chips were then irradiated to study the radiation characterization of the new TLD material produced. It is found that the developed material fulfill the characteristic of standard dosimeter with reproducibility and linearity better than 5% and sensitivity is more than 2 times compared to commercial product. (author)

  20. New spark test device for material characterization

    CERN Document Server

    Kildemo, Morten

    2004-01-01

    An automated spark test system based on combining field emission and spark measurements, exploiting a discharging capacitor is investigated. In particular, the remaining charge on the capacitor is analytically solved assuming the field emitted current to follow the Fowler Nordheim expression. The latter allows for field emission measurements from pA to A currents, and spark detection by complete discharge of the capacitor. The measurement theory and experiments on Cu and W are discussed.

  1. 300-FF-1 physical separations CERCLA treatability test plan

    International Nuclear Information System (INIS)

    1993-05-01

    This test plan describes specifications, responsibilities, and general procedures to be followed to conduct physical separations soil treatability tests in the north process pond of the 300-FF-1 Operable Unit at the Hanford Site. The overall objective of these tests is to evaluate the use of physical separations systems as a means of concentrating chemical and radioactive contaminants into fine soil fractions, and thereby minimizing waste volumes. If successful, the technology could be applied to clean up millions of cubic meters of contaminated soils at Hanford and other sites. In this document, physical separations refers to a simple and comparatively low cost technology to potentially achieve a significant reduction in the volume of contaminated soils without the use of chemical processes. Removal of metals and radioactive contaminants from the fine fraction of soils may require additional treatment such as chemical extraction, electromagnetic separation, or stabilization. Investigations/testing of these technologies are recommended to assess the economic and technical feasibility of additional treatment, but are not within the scope of this test. This plan provides guidance and specifications for two proposed treatability tests: one to be conducted by Westinghouse Hanford Company; and another proposed as competitive bid service contract. The main body of this test plan discusses the tests in general and items that are common to both tests. Attachment A discusses in detail the EPA system test and Attachment B discusses the vendor test

  2. Physical examination tests for hip dysfunction and injury.

    Science.gov (United States)

    Reiman, Michael P; Mather, Richard C; Cook, Chad E

    2015-03-01

    Physical examination tests for hip dysfunction and injury of the strongest diagnostic accuracy were identified in a recent systematic review with meta-analysis in BJSM. These tests are described in this article. A detailed description of the various different tests is given, with photographs for each test procedure. Diagnostic interpretation of each test requires careful consideration, with special attention to specific variables such as test performance and patient population. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Environmental Characterization of Mine Countermeasure Test Ranges: Hydrography and Water Column Optics

    Science.gov (United States)

    2015-09-30

    OBJECTIVES We proposed to characterize the physical, biological and optical fields present during deployments of the Streak Tube Imaging Lidar ...Environmental Characterization of Mine Countermeasure Test Ranges: Hydrography and Water Column Optics David A. Phinney Bigelow Laboratory for...email: csyentsch@aol.com Grant Number: N00014-01-1-0040 LONG-TERM GOALS We wish to observe the hydrographic factors that regulate optical

  4. Physical, mechanical and rheological properties of polymers: test facilities and experiences

    International Nuclear Information System (INIS)

    Zahid Abdullah

    2005-01-01

    The laboratories in polymer pilot plant of BTPS, MINT TECH-PARK well equipped with various polymer testing facilities. The determination of physical, mechanical and rheological properties of polymers are very important not only for research purpose but also for characterizations of polymer products from industries. This paper illustrates the polymer testing facilities available at polymer pilot plant of BTPS. The discussion includes the list of equipment, applications, customers, experience and problem faced during the daily operation. (Author)

  5. Optical Microscopy Characterization for Borehole U-15n#12 in Support of NCNS Source Physics Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Jennifer E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sussman, Aviva Joy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-05-22

    Optical microscopy characterization of thin sections from corehole U-15n#12 is part of a larger material characterization effort for the Source Physics Experiment (SPE). The SPE program was conducted in Nevada with a series of explosive tests designed to study the generation and propagation of seismic waves inside Stock quartz monzonite. Optical microscopy analysis includes the following: 1) imaging of full thin sections (scans and mosaic maps); 2) high magnification imaging of petrographic texture (grain size, foliations, fractures, etc.); and 3) measurement of microfracture density.

  6. A simulated test of physical starting and reactor physics on zero power facility of PWR

    International Nuclear Information System (INIS)

    Yao Zewu; Ji Huaxiang; Chen Zhicheng; Yao Zhiquan; Chen Chen; Li Yuwen

    1995-01-01

    The core neutron economics has been verified through experiments conducted at a zero power reactor with baffles of various thickness. A simulated test of physical starting of Qinshan PWR has been introduced. The feasibility and safety of the programme are verified. The research provides a valuable foundation for developing physical starting programme

  7. VISCOSE BASED MAGNETIC YARNS – PHYSICAL AND MECHANICAL CHARACTERIZATION

    Directory of Open Access Journals (Sweden)

    GROSU Marian-Cătălin

    2017-05-01

    Full Text Available In the context of the rapid growth in the number of electrical and electronic devices and accessories that emit electromagnetic energy in different frequency bands we present and characterize here several magnetic functionalized viscose twisted yarns. A 100% viscose twisted staple yarn was covered through an in-house developed process with a polymeric solution containing micrometric sized barium hexaferrite magnetic powder. The in-house developed process allows deposition of micrometric thickness polymeric paste layer on the yarn surface. Barium hexaferrite is a hard magnetic material exhibiting high chemical stability and corrosion resistivity, relatively large saturation and residual magnetization and microwave absorbing properties. Five different percentages of the magnetic powder in the polymer solution were used, i.e. ranging from 15 wt% to 45 wt%. Physical characterization shows a very good adherence between the highly hygroscopic viscose staple fibers and the polymeric solution that contains polyvinyl acetate and polyurethane as binders. SEM images evidenced the fact that the polymeric solution penetrated more than 1/3 of the yarn diameter. The concentration of magnetic powder in the polymeric solution has a direct influence on the coating amount, diameter and density. The mechanical characterization of the coated yarns revealed that the breaking force is increasing with increasing magnetic powder content up to o certain value and then decreased because the magnetic layer became stiffer. At the same time, the elongation at brake is decreasing.

  8. Asphalt mix characterization using dynamic modulus and APA testing.

    Science.gov (United States)

    2005-11-01

    final report summarizes two research efforts related to asphalt mix characterization: dynamic modulus and Asphalt Pavement Analyzer testing. One phase of the research consisted of a laboratory-based evaluation of dynamic modulus of Oregon dense-grade...

  9. Reliable and sensitive physical testing of elite trapeze sailors

    DEFF Research Database (Denmark)

    Bay, Jonathan; Bojsen-Møller, Jens; Nordsborg, Nikolai Baastrup

    2018-01-01

    It was investigated, if a newly developed discipline specific test for elite-level trapeze sailors is reli-able and sensitive. Furthermore, the physical demands of trapeze sailing were examined. In part 1, nine national team athletes were accustomed to a simulated sailing test, which subsequently...... as peak values were 83.5 ± 11.4% and 89.9 ± 1.7% of max, respectively. In conclusion, the present test is reliable and sensitive, thus providing a sailing specific alternative to traditional physical testing of elite trapeze sailors. Additionally, on-water rac-ing requires moderate aerobic energy...... was completed on four occasions to determine test reliability and sensitivity to manipulations in body-weight. Rope-pulling mean power output (MPO), oxygen consumption (VO2 ), heart rate (HR) and blood lactate values were acquired in all trials. In part 2, six sailors completed on-water racing with concurrent...

  10. Physical separations soil washing system cold test results

    Energy Technology Data Exchange (ETDEWEB)

    McGuire, J.P.

    1993-07-28

    This test summary describes the objectives, methodology, and results of a physical separations soil-washing system setup and shakedown test using uncontaminated soil. The test is being conducted in preparation for a treatability test to be conducted in the North Pond of the 300-FF-1 Operable Unit. It will be used to assess the feasibility of using a physical separations process to reduce the volume of contaminated soils in the 300-FF-1 Operable Unit. The test is described in DOE-RL (1993). The setup test was conducted at an uncontrolled area located approximately 3.2 km northwest of the 300-FF-1 Operable Unit. The material processed was free of contamination. The physical separation equipment to be used in the test was transferred to the US Department of Energy (DOE) by the US Environmental Protection Agency (EPA) Risk Reduction Engineering Laboratory. On May 13, 1993, soil-washing equipment was moved to the cold test location. Design assistance and recommendation for operation was provided by the EPA.

  11. A test harness for accelerating physics parameterization advancements into operations

    Science.gov (United States)

    Firl, G. J.; Bernardet, L.; Harrold, M.; Henderson, J.; Wolff, J.; Zhang, M.

    2017-12-01

    The process of transitioning advances in parameterization of sub-grid scale processes from initial idea to implementation is often much quicker than the transition from implementation to use in an operational setting. After all, considerable work must be undertaken by operational centers to fully test, evaluate, and implement new physics. The process is complicated by the scarcity of like-to-like comparisons, availability of HPC resources, and the ``tuning problem" whereby advances in physics schemes are difficult to properly evaluate without first undertaking the expensive and time-consuming process of tuning to other schemes within a suite. To address this process shortcoming, the Global Model TestBed (GMTB), supported by the NWS NGGPS project and undertaken by the Developmental Testbed Center, has developed a physics test harness. It implements the concept of hierarchical testing, where the same code can be tested in model configurations of varying complexity from single column models (SCM) to fully coupled, cycled global simulations. Developers and users may choose at which level of complexity to engage. Several components of the physics test harness have been implemented, including a SCM and an end-to-end workflow that expands upon the one used at NOAA/EMC to run the GFS operationally, although the testbed components will necessarily morph to coincide with changes to the operational configuration (FV3-GFS). A standard, relatively user-friendly interface known as the Interoperable Physics Driver (IPD) is available for physics developers to connect their codes. This prerequisite exercise allows access to the testbed tools and removes a technical hurdle for potential inclusion into the Common Community Physics Package (CCPP). The testbed offers users the opportunity to conduct like-to-like comparisons between the operational physics suite and new development as well as among multiple developments. GMTB staff have demonstrated use of the testbed through a

  12. Test-retest reliability of a questionnaire to assess physical environmental factors pertaining to physical activity

    Directory of Open Access Journals (Sweden)

    McGinn Aileen P

    2005-06-01

    Full Text Available Abstract Background Despite the documented benefits of physical activity, many adults do not obtain the recommended amounts. Barriers to physical activity occur at multiple levels, including at the individual, interpersonal, and environmental levels. Only until more recently has there been a concerted focus on how the physical environment might affect physical activity behavior. With this new area of study, self-report measures should be psychometrically tested before use in research studies. Therefore the objective of this study was to document the test-retest reliability of a questionnaire designed to assess physical environmental factors that might be associated with physical activity in a diverse adult population. Methods Test and retest surveys were conducted over the telephone with 106 African American and White women and men living in either Forsyth County, North Carolina or Jackson, Mississippi. Reliability of self-reported environmental factors across four domains (e.g., access to facilities and destinations, functionality and safety, aesthetics, natural environment was determined using intraclass correlation coefficients (ICC overall and separately by gender and race. Results Generally items displayed moderate and sometimes substantial reliability (ICC between 0.4 to 0.8, with a few differences by gender or race, across each of the domains. Conclusion This study provides some psychometric evidence for the use of many of these questions in studies examining the effect of self-reported physical environmental measures on physical activity behaviors, among African American and White women and men.

  13. Chemical and Physical Characterization of Stabilized Polyacrylonitrile (PAN Fiber.

    Directory of Open Access Journals (Sweden)

    Salleh Shahrul Nizam Md

    2014-07-01

    Full Text Available Fibers Stabilization is an exothermic process which involves heat treatment at lower temperature from 150 °C to 300 °C. It is considered as a crucial step that will determine the final structure of the carbon fibre and its mechanical properties. This work involves comparison of physical and mechanical properties of Polyacrylonitrile (PAN and stabilized Polyacrylonitrile (PAN fiber produced from batch process. The functional group of the fibre was studied using ATR-FTIR and the morphology was characterised by AFM and SEM. Mechanical properties of the fibers will be studies using single column tensile machine with ASTM D3822 testing procedure. The studies show significant change of physical and mechanical properties of Polyacrylonitrile (PAN and stabilized Polyacrylonitrile (PAN fiber. This lead to different application for every type of fibers produced before and after stabilization process.

  14. Characterization of konjac glucomannan-gelatin IPN physical hydrogel scaffold

    Science.gov (United States)

    Chen, Xiliang; Chen, Qinghua; Yan, Tingting; Liu, Jinkun

    2017-06-01

    A novel IPN hydrogel scaffold is prepared by freeze-drying method, in which konjac galactomannan (KGM) and gelatin are physically crosslinked respectively. This scaffold is thermostable, and the structure of this scaffold is analysed by scanning electron microscope, Fourier transform infrared spectrum, and X-ray diffraction method. The FT-IR results show that hydrogen bonds are formed between KGM and gelatin molecules, which hinder the formation of their respective crosslinking. This is consistent with the XRD results that the crystallinity gets lower in the IPN gels compared with pure gelatin and KGM gels. The morphologies of freeze-dried hydrogels are observed by SEM and the mechanical properties of the scaffolds are tested to analyse the relationship between the structures and properties. Although this novel IPN hydrogel is physical gel, it shows rubber-like performance as chemical gels. And it is nontoxic, so it can be used as the scaffold for cartilage tissue engineering that embedded in human bodies.

  15. Physical Characterization and Steam Chemical Reactivity of Carbon Fiber Composites

    Energy Technology Data Exchange (ETDEWEB)

    Anderl, Robert Andrew; Pawelko, Robert James; Smolik, Galen Richard

    2001-05-01

    This report documents experiments and analyses that have been done at the Idaho National Engineering and Environmental Laboratory (INEEL) to measure the steam chemical reactivity of two types of carbon fiber composites, NS31 and NB31, proposed for use at the divertor strike points in an ITER-like tokamak. These materials are 3D CFCs constituted by a NOVOLTEX preform and densified by pyrocarbon infiltration and heat treatment. NS31 differs from NB31 in that the final infiltration was done with liquid silicon to reduce the porosity and enhance the thermal conductivity of the CFC. Our approach in this work was twofold: (1) physical characterization measurements of the specimens and (2) measurements of the chemical reactivity of specimens exposed to steam.

  16. Chemical and Physical Characterization of Fly Ash as Geopolymer Material

    Directory of Open Access Journals (Sweden)

    Risdanareni Puput

    2017-01-01

    Full Text Available Research on finding suitable cement substitute material becomes massive due to environmental effect. Geopolymer as inorganic material is potential to be the smart solution to overcome global warming issue. Fly ash is a waste material rich in silica and alumina becomes popular raw material to produce geopolymer. The best properties ofgeopolymer paste come from the high quality of fly ash. Therefore, it is important to investigate various types of fly ash and geopolymer properties. Their chemical and physical properties characterized by XRF, pH value, XRD and SEM. The results showed that type of fly ash depended on amount of Si-based of Ca-based compound which consisted of spherical morphology. Geopolymer paste produced from the ash with different compound has bulky and irregular shape morphology. The pH value of each ash has also a correlation with the setting time of fresh paste.

  17. Physical Characterization and Steam Chemical Reactivity of Carbon Fiber Composites

    International Nuclear Information System (INIS)

    Anderl, Robert Andrew; Pawelko, Robert James; Smolik, Galen Richard

    2001-01-01

    This report documents experiments and analyses that have been done at the Idaho National Engineering and Environmental Laboratory (INEEL) to measure the steam chemical reactivity of two types of carbon fiber composites, NS31 and NB31, proposed for use at the divertor strike points in an ITER-like tokamak. These materials are 3D CFCs constituted by a NOVOLTEX preform and densified by pyrocarbon infiltration and heat treatment. NS31 differs from NB31 in that the final infiltration was done with liquid silicon to reduce the porosity and enhance the thermal conductivity of the CFC. Our approach in this work was twofold: (1) physical characterization measurements of the specimens and (2) measurements of the chemical reactivity of specimens exposed to steam

  18. Physical characterization of asteroid surfaces from photometric analysis

    Science.gov (United States)

    Helfenstein, P.; Veverka, J.

    1989-01-01

    The feasibility of using photometric models like Hapke's (1981, 1984, 1986) equation for deriving physical properties of asteroids from photometric observations is discussed. Using data for Ceres and Vesta, it is shown that the incomplete phase-angle coverage limits the reliable determination of Hapke's photometric parameters from asteroid disk-integrated phase curves (the second limitation is the nonsphericity of many asteroids). However, within this limitations, certain trends among asteroids can be compared. It is shown that there is a general similarity among the Hapke's parameters other than the h parameter, which characterizes the width of the opposition surge in terms of soil structure (porosity, particle-size distribution, and the rate of compaction with depth), derived for similar objects, e.g., average C asteroids and Ceres, and average S asteroids, 1982 Apollo, and Vesta.

  19. Physical and chemical characterization techniques for metallic powders

    International Nuclear Information System (INIS)

    Slotwinski, J. A.; Stutzman, P. E.; Ferraris, C. F.; Watson, S. S.; Peltz, M. A.; Garboczi, E. J.

    2014-01-01

    Systematic studies have been carried out on two different powder materials used for additive manufacturing: stainless steel and cobalt-chrome. An extensive array of characterization techniques were applied to these two powders. The physical techniques included laser-diffraction particle-size analysis, X-ray computed tomography for size and shape analysis, and optical and scanning electron microscopy. Techniques sensitive to chemistry included X-ray diffraction and energy-dispersive analytical X-ray analysis. The background of these techniques will be summarized and some typical findings comparing different samples of virgin additive manufacturing powders, taken from the same lot, will be given. The techniques were used to confirm that different samples of powder from the same lot were essentially identical, within the uncertainty of the measurements

  20. Characterization and Leach Testing for REDOX Sludge and S-Saltcake Actual Waste Sample Composites

    Energy Technology Data Exchange (ETDEWEB)

    Fiskum, Sandra K.; Buck, Edgar C.; Daniel, Richard C.; Draper, Kathryn E.; Edwards, Matthew K.; Hubler, Timothy L.; Jagoda, Lynette K.; Jenson, Evan D.; Kozelisky, Anne E.; Lumetta, Gregg J.; MacFarlan, Paul J.; McNamara, Bruce K.; Peterson, Reid A.; Sinkov, Sergey I.; Snow, Lanee A.; Swoboda, Robert G.

    2008-07-10

    This report describes processing and analysis results of boehmite waste type (Group 5) and insoluble high Cr waste type (Group 6). The sample selection, compositing, subdivision, physical and chemical characterization are described. Extensive batch leach testing was conducted to define kinetics and leach factors of selected analytes as functions of NaOH concentration and temperature. Testing supports issue M-12 resolution for the Waste Treatment Plant.

  1. Application of physical and chemical characterization techniques to metallic powders

    International Nuclear Information System (INIS)

    Slotwinski, J. A.; Watson, S. S.; Stutzman, P. E.; Ferraris, C. F.; Peltz, M. A.; Garboczi, E. J.

    2014-01-01

    Systematic studies have been carried out on two different powder materials used for additive manufacturing: stainless steel and cobalt-chrome. The characterization of these powders is important in NIST efforts to develop appropriate measurements and standards for additive materials and to document the property of powders used in a NIST-led additive manufacturing material round robin. An extensive array of characterization techniques was applied to these two powders, in both virgin and recycled states. The physical techniques included laser diffraction particle size analysis, X-ray computed tomography for size and shape analysis, and optical and scanning electron microscopy. Techniques sensitive to chemistry, including X-ray diffraction and energy dispersive analytical X-ray analysis using the X-rays generated during scanning electron microscopy, were also employed. Results of these analyses will be used to shed light on the question: how does virgin powder change after being exposed to and recycled from one or more additive manufacturing build cycles? In addition, these findings can give insight into the actual additive manufacturing process

  2. Physiological capacity and physical testing in male elite team handball

    DEFF Research Database (Denmark)

    Michalsik, Lars Bojsen; Madsen, K.; Aagaard, P.

    2015-01-01

    and by subsequent physical testing. RESULTS: Mean heart rate and relative workload during match-play (N.=41) were 163 ± 5 beats·min⁻¹ (group means±SD) and 70.9 ± 6.0% of VO(2-max), respectively. Relative workload was lower (P... and high demands on the anaerobic energy systems during certain periods of the match. Indications of temporary fatigue and a subsequent decline in performance were observed, since the relative workload decreased both in the first and in the second half of the match. Physiological profiles and physical test......AIM: The aim of the present study was to examine the physical demands placed on male elite team handball players in relation to playing position. METHODS: Male elite team handball field players were evaluated during match-play over a six season time span using physiological measurements...

  3. Classroom Tests and Achievement in Problem Solving in Physical Geography

    Science.gov (United States)

    Monk, Janice J.; Stallings, William M.

    1975-01-01

    Two hundred students in an undergraduate physical geography course were assigned to a group which received either factually oriented quizzes or quizzes which stressed higher level behaviors such as application and analysis. Evaluation of the results indicated that the variation in testing procedures had no discernable effect on student scores in…

  4. Measuring damage in physical model tests of rubble mounds

    NARCIS (Netherlands)

    Hofland, B.; Rosa-Santos, Paulo; Taveira-Pinto, Francisco; Lemos, Rute; Mendonça, A.; Juana Fortes, C

    2017-01-01

    This paper studies novel ways to evaluate armour damage in physical models of coastal structures. High-resolution damage data for reference rubble mound breakwaters obtained under the HYDRALAB+ joint-research project are analysed and discussed. These tests are used to analyse the way to describe

  5. Two methodologies for physical penetration testing using social engineering

    NARCIS (Netherlands)

    Dimkov, T.; Pieters, Wolter; Hartel, Pieter H.

    2009-01-01

    During a penetration test on the physical security of an organization, if social engineering is used, the penetration tester directly interacts with the employees. These interactions are usually based on deception and if not done properly can upset the employees, violate their privacy or damage

  6. Benchmark and physics testing of LIFE-4C. Summary

    International Nuclear Information System (INIS)

    Liu, Y.Y.

    1984-06-01

    LIFE-4C is a steady-state/transient analysis code developed for performance evaluation of carbide [(U,Pu)C and UC] fuel elements in advanced LMFBRs. This paper summarizes selected results obtained during a crucial step in the development of LIFE-4C - benchmark and physics testing

  7. Physical characterization of core samples recovered from Gulf of Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Tae Sup; Carlos Santamarina, J. [School of Civil and Environmental Engineering, Georgia Institute of Technology, 790 Atlantic Drive, Atlanta, GA 30332-0355 (United States); Narsilio, Guillermo A. [Department of Civil and Environmental Engineering, The University of Melbourne, Engineering Block D 321, Parkville, VIC 3010 (Australia)

    2006-12-15

    Seventy whole rounds from conventional cores obtained during drilling to 300mbsf at Atwater Valley and Keathley Canyon in the Gulf of Mexico in April and May 2005 were tested to determine geophysical and geomechanical parameters (liquid and plastic limit, porosity, specific surface, pH, sediment electrical conductivity, P- and S-wave velocities and undrained shear strength). Available data from a pressure core are included as well. Results show that the sediments are high specific surface plastic clays, and exhibit pronounced time-dependent stiffness recovery. Strains during coring disturb specimens, yet, the water content retains the effective stress history and permits gaining stiffness and strength information from conventional cores. Remolding is exacerbated when gas expands upon decompression; the limited pressure core data available show the advantages of preserving the pore fluid pressure during core recovery and testing. Valuable parameters for sediment characterization and engineering analysis are extracted from the data using pre-existing soil models. (author)

  8. Principles of Technology Student Achievement in Advanced Physics Measured by a Normed Physics Test.

    Science.gov (United States)

    Nicholson, James Alan

    1991-02-01

    The Principles of Technology (PT) curriculum, now in approximately 1,200 schools, has produced a profound change in the delivery of applied physics. If high school PT programs and traditional physics courses deliver comparable student outcomes, as some research suggests, the PT curriculum may find wider acceptance in vocational programs and postsecondary schools may have rationale for accepting PT as physics. This study measured PT student performance on an advanced physics test, after they have had one year (7 units) of PT. The 1988R version of the National Association of Physics Teachers and National Science Teachers Association physics test, with more than 7500 copies sold, was selected as the research instrument. This test covers advanced aspects of traditional high school physics. A secondary enquiry included an attempt to link PT teacher preparation and credentialing and/or PT site demographics to variation in PT student scores on the 1988R test. The 10 PT sites in this study were self-selected from the 29 PT field study schools, the most mature PT sites. The researcher determined, that the 1988R physics test lacked content validity for the PT students tested. The PT students tested had a composite mean score of 17.67 questions correct out of 80, (below the second percentile), not statistically different than a chance score. No differences were found between site mean scores. Interpretation of the results regarding the effect of teachers, or demographics was not justified. The value of PT to the vocational-technical programs that it was designed for was not measured, nor was the awarding of general science credit for PT completion. One year of the PT curriculum, at the sampled schools, has not prepared students in the advanced scientific aspects of traditional physics found on the 1988R examination. The primary implication is that educators should not expect year one PT to prepare students for classes or curricula that include traditional physics as a

  9. Asymptotic formulae for likelihood-based tests of new physics

    Science.gov (United States)

    Cowan, Glen; Cranmer, Kyle; Gross, Eilam; Vitells, Ofer

    2011-02-01

    We describe likelihood-based statistical tests for use in high energy physics for the discovery of new phenomena and for construction of confidence intervals on model parameters. We focus on the properties of the test procedures that allow one to account for systematic uncertainties. Explicit formulae for the asymptotic distributions of test statistics are derived using results of Wilks and Wald. We motivate and justify the use of a representative data set, called the "Asimov data set", which provides a simple method to obtain the median experimental sensitivity of a search or measurement as well as fluctuations about this expectation.

  10. Asymptotic formulae for likelihood-based tests of new physics

    Energy Technology Data Exchange (ETDEWEB)

    Cowan, Glen [Royal Holloway, University of London, Physics Department, Egham (United Kingdom); Cranmer, Kyle [New York University, Physics Department, New York, NY (United States); Gross, Eilam; Vitells, Ofer [Weizmann Institute of Science, Rehovot (Israel)

    2011-02-15

    We describe likelihood-based statistical tests for use in high energy physics for the discovery of new phenomena and for construction of confidence intervals on model parameters. We focus on the properties of the test procedures that allow one to account for systematic uncertainties. Explicit formulae for the asymptotic distributions of test statistics are derived using results of Wilks and Wald. We motivate and justify the use of a representative data set, called the ''Asimov data set'', which provides a simple method to obtain the median experimental sensitivity of a search or measurement as well as fluctuations about this expectation. (orig.)

  11. Description and characterization of HBWR Series H-1 test rods

    International Nuclear Information System (INIS)

    Wagoner, S.R.; Barner, J.O.; Welty, R.K.

    1979-06-01

    The as-built characterization results are presented for the HBWR Series H-1 test rods to be irradiated as part of the Fuel Performance Improvement Program (FPIP). The irradiation of these rods is to be conducted in the Halden Boiling Water Reactor (HBWR). Series H-1 consists of twelve rods for irradiation and six spares. Rod design types include (1) a reference dished pellet design, (2) an annular pellet design, (3) an annular pellet design combined with graphite-coated cladding, and (4) a packed-particle (vipac) design. The report, which describes the fabrication and detailed characterization results for the rods, is divided into four major sections: (1) experiment description, (2) process development required to fabricate the test rods, (3) methods and procedures used to fabricate and characterize the rods, and (4) a summary of the characterization results

  12. Nuclear physics at PEP: First test and future plans

    International Nuclear Information System (INIS)

    Van Bibber, K.; Dietrich, F.S.; Melnikoff, S.O.

    1986-09-01

    A test run of internal target nuclear physics at the PEP storage ring is described. The Time Projection Chamber (TPC-2γ detector) was used to detect the inelastically scattered electron and complete hadronic final state in the interaction of 14.5 GeV electrons with D 2 , Ar and Xe gas targets. The data comprise mostly low-x low-Q 2 events, but some deep inelastic scattering as well. The future possibilities of a dedicated nuclear physics program at PEP are outlined. 15 refs., 25 figs

  13. Physiological capacity and physical testing in male elite team handball.

    Science.gov (United States)

    Michalsik, L B; Madsen, K; Aagaard, P

    2015-05-01

    The aim of the present study was to examine the physical demands placed on male elite team handball players in relation to playing position. Male elite team handball field players were evaluated during match-play over a six season time span using physiological measurements and by subsequent physical testing. Mean heart rate and relative workload during match-play (N.=41) were 163 ± 5 beats·min⁻¹ (group means±SD) and 70.9 ± 6.0% of VO(2-max), respectively. Relative workload was lower (Pjumping height in "Jump and Reach" testing was 0.71 ± 0.08 m (range: 0.61-0.86 m). Maximal ball throwing speed was observed using the set shot with 3-step run-up (92.8 ± 5.3 km·h⁻¹, range: 75.8-108.2 km·h⁻¹). Modern male elite team handball imposes moderate-to-high demands on the aerobic energy system and high demands on the anaerobic energy systems during certain periods of the match. Indications of temporary fatigue and a subsequent decline in performance were observed, since the relative workload decreased both in the first and in the second half of the match. Physiological profiles and physical test results differed between playing positions, with wing players covering a greater total distance in the Yo-Yo test and showing superior jumping performance and repeated sprint running capacity than backcourt players and pivots.

  14. Characterizing interactive engagement activities in a flipped introductory physics class

    Directory of Open Access Journals (Sweden)

    Anna K. Wood

    2016-06-01

    Full Text Available Interactive engagement activities are increasingly common in undergraduate physics teaching. As research efforts move beyond simply showing that interactive engagement pedagogies work towards developing an understanding of how they lead to improved learning outcomes, a detailed analysis of the way in which these activities are used in practice is needed. Our aim in this paper is to present a characterization of the type and duration of interactions, as experienced by students, that took place during two introductory physics courses (1A and 1B at a university in the United Kingdom. Through this work, a simple framework for analyzing lectures—the framework for interactive learning in lectures (FILL, which focuses on student interactions (with the lecturer, with each other, and with the material is proposed. The pedagogical approach is based on Peer Instruction (PI and both courses are taught by the same lecturer. We find lecture activities can be categorized into three types: interactive (25%, vicarious interactive (20% (involving questions to and from the lecturer, and noninteractive (55%. As expected, the majority of both interactive and vicarious interactive activities took place during PI. However, the way that interactive activities were used during non-PI sections of the lecture varied significantly between the two courses. Differences were also found in the average time spent on lecturer-student interactions (28% for 1A and 12% for 1B, although not on student-student interactions (12% and 12% or on individual learning (10% and 7%. These results are explored in detail and the implications for future research are discussed.

  15. Physiological capacity and physical testing in male elite team handball

    DEFF Research Database (Denmark)

    Michalsik, Lars Bojsen; Madsen, K; Aagaard, Per

    2015-01-01

    Aim: The aim of the present study was to examine the physical demands placed on male elite team handball (TH) players in relation to playing position. Methods: Male elite TH field players were evaluated during match-play over a six season time span using physiological measurements and by subseque...... physical testing. Results: Mean heart rate and relative workload during match-play (n=41) were 163±5 beats·min-1 (group means±SD) and 70.9±6.0 % of VO2-max, respectively. Relative workload was lower (p......Aim: The aim of the present study was to examine the physical demands placed on male elite team handball (TH) players in relation to playing position. Methods: Male elite TH field players were evaluated during match-play over a six season time span using physiological measurements and by subsequent...

  16. Enhanced Verification Test Suite for Physics Simulation Codes

    Energy Technology Data Exchange (ETDEWEB)

    Kamm, J R; Brock, J S; Brandon, S T; Cotrell, D L; Johnson, B; Knupp, P; Rider, W; Trucano, T; Weirs, V G

    2008-10-10

    This document discusses problems with which to augment, in quantity and in quality, the existing tri-laboratory suite of verification problems used by Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and Sandia National Laboratories (SNL). The purpose of verification analysis is demonstrate whether the numerical results of the discretization algorithms in physics and engineering simulation codes provide correct solutions of the corresponding continuum equations. The key points of this document are: (1) Verification deals with mathematical correctness of the numerical algorithms in a code, while validation deals with physical correctness of a simulation in a regime of interest. This document is about verification. (2) The current seven-problem Tri-Laboratory Verification Test Suite, which has been used for approximately five years at the DOE WP laboratories, is limited. (3) Both the methodology for and technology used in verification analysis have evolved and been improved since the original test suite was proposed. (4) The proposed test problems are in three basic areas: (a) Hydrodynamics; (b) Transport processes; and (c) Dynamic strength-of-materials. (5) For several of the proposed problems we provide a 'strong sense verification benchmark', consisting of (i) a clear mathematical statement of the problem with sufficient information to run a computer simulation, (ii) an explanation of how the code result and benchmark solution are to be evaluated, and (iii) a description of the acceptance criterion for simulation code results. (6) It is proposed that the set of verification test problems with which any particular code be evaluated include some of the problems described in this document. Analysis of the proposed verification test problems constitutes part of a necessary--but not sufficient--step that builds confidence in physics and engineering simulation codes. More complicated test cases, including physics models of

  17. Glovebox characterization and barrier integrity testing using fluorescent powder

    International Nuclear Information System (INIS)

    Wahlquist, D.R.

    1996-01-01

    This paper presents a method for characterizing the spread of contamination and testing the barrier integrity of a new glovebox during material transfer operations and glove change-outs using fluorescent powder. Argonne National Laboratory-West has performed this test on several new gloveboxes prior to putting them into service. The test is performed after the glovebox has been leak tested and all systems have been verified to be operational. The purpose of the test is to show that bag-in/bag-out operations and glove change-outs can be accomplished without spreading the actual contaminated material to non-contaminated areas. The characterization test also provides information as to where contamination might be expected to build-up during actual operations. The fluorescent powder is used because it is easily detectable using an ultra-violet light and disperses in a similar fashion to radioactive material. The characterization and barrier integrity test of a glovebox using fluorescent powder provides a visual method of determining areas of potential contamination accumulation and helps evaluate the ability to perform clean transfer operations and glove change-outs

  18. Physical characterization of hydroxyapatite porous scaffolds for tissue engineering

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, S., E-mail: smsilva@ineb.up.pt [INEB - Instituto de Engenharia Biomedica, Divisao de Biomateriais, Universidade do Porto, Rua do Campo Alegre, 823, 4150-180 Porto (Portugal); Universidade do Porto, Faculdade de Engenharia, Departamento de Engenharia Metalurgica e Materiais, Porto (Portugal); Rodriguez, M.A.; Pena, P.; De Aza, A.H.; De Aza, S. [Instituto de Ceramica y Vidrio, CSIC, 28049-Cantoblanco, Madrid (Spain); Ferraz, M.P. [INEB - Instituto de Engenharia Biomedica, Divisao de Biomateriais, Universidade do Porto, Rua do Campo Alegre, 823, 4150-180 Porto (Portugal); Faculdade de Ciencias da Saude da Universidade Fernando Pessoa, Rua Carlos da Maia, 296, 4200-150 Porto (Portugal); Monteiro, F.J. [INEB - Instituto de Engenharia Biomedica, Divisao de Biomateriais, Universidade do Porto, Rua do Campo Alegre, 823, 4150-180 Porto (Portugal); Universidade do Porto, Faculdade de Engenharia, Departamento de Engenharia Metalurgica e Materiais, Porto (Portugal)

    2009-06-01

    The present study refers to the preparation and characterization of porous hydroxyapatite scaffolds to be used as matrices for bone regeneration or as specific release vehicles. Ceramics are widely used for bone tissue engineering purposes and in this study, hydroxyapatite porous scaffolds were produced using the polymer replication method. Polyurethane sponges were used as templates and impregnated with a ceramic slurry at different ratios, and sintered at 1300 deg. C following a specific thermal cycle. The characteristics of the hydroxyapatite porous scaffolds and respective powder used as starting material, were investigated by using scanning electron microscopy, particle size distribution, X-ray diffraction, Fourier transformed infrared spectroscopy and compressive mechanical testing techniques. It was possible to produce highly porous hydroxyapatite scaffolds presenting micro and macropores and pore interconnectivity.

  19. Blind Test of Physics-Based Prediction of Protein Structures

    Science.gov (United States)

    Shell, M. Scott; Ozkan, S. Banu; Voelz, Vincent; Wu, Guohong Albert; Dill, Ken A.

    2009-01-01

    We report here a multiprotein blind test of a computer method to predict native protein structures based solely on an all-atom physics-based force field. We use the AMBER 96 potential function with an implicit (GB/SA) model of solvation, combined with replica-exchange molecular-dynamics simulations. Coarse conformational sampling is performed using the zipping and assembly method (ZAM), an approach that is designed to mimic the putative physical routes of protein folding. ZAM was applied to the folding of six proteins, from 76 to 112 monomers in length, in CASP7, a community-wide blind test of protein structure prediction. Because these predictions have about the same level of accuracy as typical bioinformatics methods, and do not utilize information from databases of known native structures, this work opens up the possibility of predicting the structures of membrane proteins, synthetic peptides, or other foldable polymers, for which there is little prior knowledge of native structures. This approach may also be useful for predicting physical protein folding routes, non-native conformations, and other physical properties from amino acid sequences. PMID:19186130

  20. Differences in gender performance on competitive physics selection tests

    Directory of Open Access Journals (Sweden)

    Kate Wilson

    2016-08-01

    Full Text Available [This paper is part of the Focused Collection on Gender in Physics.] We have investigated gender differences in performance over the past eight years on the Australian Science Olympiad Exam (ASOE for physics, which is taken by nearly 1000 high school students each year. The ASOE, run by Australian Science Innovations (ASI, is the initial stage of the process of selection of teams to represent Australia at the Asian and International Physics Olympiads. Students taking the exam are generally in their penultimate year of school and selected by teachers as being high performing in physics. Together with the overall differences in facility, we have investigated how the content and presentation of multiple-choice questions (MCQs affects the particular answers selected by male and female students. Differences in the patterns of responses by male and female students indicate that males and females might be modeling situations in different ways. Some strong patterns were found in the gender gaps when the questions were categorized in five broad dimensions: content, process required, difficulty, presentation, and context. Almost all questions saw male students performing better, although gender differences were relatively small for questions with a more abstract context. Male students performed significantly better on most questions with a concrete context, although notable exceptions were found, including two such questions where female students performed better. Other categories that showed consistently large gaps favoring male students include questions with projectile motion and other two-dimensional motion or forces content, and processes involving interpreting diagrams. Our results have important implications, suggesting that we should be able to reduce the gender gaps in performance on MCQ tests by changing the way information is presented and setting questions in contexts that are less likely to favor males over females. This is important as MCQ

  1. Differences in gender performance on competitive physics selection tests

    Science.gov (United States)

    Wilson, Kate; Low, David; Verdon, Matthew; Verdon, Alix

    2016-12-01

    [This paper is part of the Focused Collection on Gender in Physics.] We have investigated gender differences in performance over the past eight years on the Australian Science Olympiad Exam (ASOE) for physics, which is taken by nearly 1000 high school students each year. The ASOE, run by Australian Science Innovations (ASI), is the initial stage of the process of selection of teams to represent Australia at the Asian and International Physics Olympiads. Students taking the exam are generally in their penultimate year of school and selected by teachers as being high performing in physics. Together with the overall differences in facility, we have investigated how the content and presentation of multiple-choice questions (MCQs) affects the particular answers selected by male and female students. Differences in the patterns of responses by male and female students indicate that males and females might be modeling situations in different ways. Some strong patterns were found in the gender gaps when the questions were categorized in five broad dimensions: content, process required, difficulty, presentation, and context. Almost all questions saw male students performing better, although gender differences were relatively small for questions with a more abstract context. Male students performed significantly better on most questions with a concrete context, although notable exceptions were found, including two such questions where female students performed better. Other categories that showed consistently large gaps favoring male students include questions with projectile motion and other two-dimensional motion or forces content, and processes involving interpreting diagrams. Our results have important implications, suggesting that we should be able to reduce the gender gaps in performance on MCQ tests by changing the way information is presented and setting questions in contexts that are less likely to favor males over females. This is important as MCQ tests are

  2. Characterization and Dissolution Kinetics Testing of Radioactive H-3 Calcine

    Energy Technology Data Exchange (ETDEWEB)

    Garn, Troy Gerry; Batcheller, Thomas Aquinas

    2002-09-01

    Characterization and dissolution kinetics testing were performed with Idaho radioactive H-3 calcine. Calcine dissolution is the key front-end unit operation for the Separations Alternative identified in the Idaho High Level Waste Draft EIS. The impact of the extent of dissolution on the feasibility of Separations must be clearly quantified.

  3. Reactor Physics Characterization of the HTR Module with UCO Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Gerhard Strydom

    2011-01-01

    ABSTRACT The HTR Module [1] is a graphite-moderated, helium cooled pebble bed High Temperature Reactor (HTR) design that has been extensively used as a reference template for the former South African and current Chinese HTR [2] programs. This design utilized spherical fuel elements packed into a dynamic pebble bed, consisting of TRISO coated uranium oxide (UO2) fuel kernels with a U-235 enrichment of 7.8% and a Heavy Metal loading of 7 grams per pebble. The main objective of this study is to compare several important reactor physics and core design parameters for the HTR Module and an identical design utilizing UCO fuel kernels. Fuel kernels of this type are currently being tested in the Idaho National Laboratory’s (INL) Advanced Test Reactor (ATR) as part of the larger Next Generation Nuclear Plant (NGNP) project. The PEBBED-THERMIX [3] code, which was developed specifically for the analysis of pebble bed HTRs, was used to compare the coupled neutronic and thermal fluid performance of the two designs.

  4. Physical and Electrical Characterization of Aluminum Polymer Capacitors

    Science.gov (United States)

    Liu, David (Donghang)

    2010-01-01

    Conductive polymer aluminum capacitor (PA capacitor) is an evolution of traditional wet electrolyte aluminum capacitors by replacing liquid electrolyte with a solid, highly conductive polymer. On the other hand, the cathode construction in polymer aluminum capacitors with coating of carbon and silver epoxy for terminal connection is more like a combination of the technique that solid tantalum capacitor utilizes. This evolution and combination result in the development of several competing capacitor construction technologies in manufacturing polymer aluminum capacitors. The driving force of this research on characterization of polymer aluminum capacitors is the rapid progress in IC technology. With the microprocessor speeds exceeding a gigahertz and CPU current demands of 80 amps and more, the demand for capacitors with higher peak current and faster repetition rates bring conducting polymer capacitors to the center o( focus. This is because this type of capacitors has been known for its ultra-low ESR and high capacitance. Polymer aluminum capacitors from several manufacturers with various combinations of capacitance, rated voltage, and ESR values were obtained and tested. The construction analysis of the capacitors revealed three different constructions: conventional rolled foil, the multilayer stacking V-shape, and a dual-layer sandwich structure. The capacitor structure and its impact on the electrical characteristics has been revealed and evaluated. A destructive test with massive current over stress to fail the polymer aluminum capacitors reveals that all polymer aluminum capacitors failed in a benign mode without ignition, combustion, or any other catastrophic failures. The extraordinary low ESR (as low as 3 mOMEGA), superior frequency independence reported for polymer aluminum capacitors have been confirmed. For the applications of polymer aluminum capacitors in space programs, a thermal vacuum cycle test was performed. The results, as expected, show no

  5. 40 CFR 230.61 - Chemical, biological, and physical evaluation and testing.

    Science.gov (United States)

    2010-07-01

    ... appropriate physical and chemical environmental characteristics. (d) Physical tests and evaluation. The effect... physical tests and evaluations as are justified and deemed necessary. Such tests may include sieve tests... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Chemical, biological, and physical...

  6. Municipal solid waste combustion: Fuel testing and characterization

    Energy Technology Data Exchange (ETDEWEB)

    Bushnell, D.J.; Canova, J.H.; Dadkhah-Nikoo, A.

    1990-10-01

    The objective of this study is to screen and characterize potential biomass fuels from waste streams. This will be accomplished by determining the types of pollutants produced while burning selected municipal waste, i.e., commercial mixed waste paper residential (curbside) mixed waste paper, and refuse derived fuel. These materials will be fired alone and in combination with wood, equal parts by weight. The data from these experiments could be utilized to size pollution control equipment required to meet emission standards. This document provides detailed descriptions of the testing methods and evaluation procedures used in the combustion testing and characterization project. The fuel samples will be examined thoroughly from the raw form to the exhaust emissions produced during the combustion test of a densified sample.

  7. Dynamic MTF, an innovative test bench for detector characterization

    Science.gov (United States)

    Emmanuel, Rossi; Raphaël, Lardière; Delmonte, Stephane

    2017-11-01

    PLEIADES HR are High Resolution satellites for Earth observation. Placed at 695km they reach a 0.7m spatial resolution. To allow such performances, the detectors are working in a TDI mode (Time and Delay Integration) which consists in a continuous charge transfer from one line to the consecutive one while the image is passing on the detector. The spatial resolution, one of the most important parameter to test, is characterized by the MTF (Modulation Transfer Function). Usually, detectors are tested in a staring mode. For a higher level of performances assessment, a dedicated bench has been set-up, allowing detectors' MTF characterization in the TDI mode. Accuracy and reproducibility are impressive, opening the door to new perspectives in term of HR imaging systems testing.

  8. High throughput testing and characterization of IR readouts and hybrids

    Science.gov (United States)

    Mandl, William J.; Bui, Khang X.; Patel, Manilal J.

    1992-07-01

    A program to upgrade the test capability for IR focal plane arrays and readouts is in progress at Aerojet. The objective of the development is to reduce the number and complexity of the steps in the test process, reduce in socket test time and provide a simplified set up procedure for production testing. There are two areas of study in the program. One is concerned with examining multiple fabrication sources for readout circuits. The application of a commercially available automated test system for production testing and engineering characterization of readouts and focal plane arrays is discussed. The Sentry Series 80 mixed signal tester is being fixtured for low noise measurements and interfacing to dewars for cryogenic testing. The multiuser foreground/background operating system software has the advantage of allowing noise and other statistical calculations to be performed in the background without impeding test measurements. It also has the advantage in production of requiring no manual instrumentation set up or interconnect. The improvements in test throughput and analysis capability will be shown in adapting this class of tester as opposed to assembling test instruments in a custom made computer controlled test approach.

  9. A wave model test bed study for wave energy resource characterization

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Zhaoqing; Neary, Vincent S.; Wang, Taiping; Gunawan, Budi; Dallman, Annie R.; Wu, Wei-Cheng

    2017-12-01

    This paper presents a test bed study conducted to evaluate best practices in wave modeling to characterize energy resources. The model test bed off the central Oregon Coast was selected because of the high wave energy and available measured data at the site. Two third-generation spectral wave models, SWAN and WWIII, were evaluated. A four-level nested-grid approach—from global to test bed scale—was employed. Model skills were assessed using a set of model performance metrics based on comparing six simulated wave resource parameters to observations from a wave buoy inside the test bed. Both WWIII and SWAN performed well at the test bed site and exhibited similar modeling skills. The ST4 package with WWIII, which represents better physics for wave growth and dissipation, out-performed ST2 physics and improved wave power density and significant wave height predictions. However, ST4 physics tended to overpredict the wave energy period. The newly developed ST6 physics did not improve the overall model skill for predicting the six wave resource parameters. Sensitivity analysis using different wave frequencies and direction resolutions indicated the model results were not sensitive to spectral resolutions at the test bed site, likely due to the absence of complex bathymetric and geometric features.

  10. A regulator's perspective on physical testing for type B packages

    International Nuclear Information System (INIS)

    Brach, William E.

    2004-01-01

    The U.S. Nuclear Regulatory Commission has a great deal of experience certifying Type B transport packages as complying with the regulations in 10 CFR Part 71. With this experience base, supporting risk studies, and with an exceptional historical safety record for transport, we are very confident in both the current regulations and the methods we use to review and certify transportation packages. Nevertheless, we have a responsibility to remain vigilant and review our regulations and implementing practices with a view towards continuous improvement. NRC regulations permit certification through testing, analyses, comparison to similar approved designs, or combinations of these methods. Testing can be further broken into scale models, components, simple models, or full-scale models. NRC does not require full-scale testing for certification of any package; however, many applicants for package certification have conducted a physical testing program to demonstrate that the package design meets the hypothetical accident conditions. The plans for a repository at Yucca Mountain have raised significant interest in the United States of America in transportation of spent fuel, and created a broad stakeholder and public interest in transportation package testing. As an expected large increase in the number of spent fuel transports nears, this interest will likely grow. The technical and regulatory reasons for, or for not, performing tests need to be well understood and communicated to all stakeholders

  11. Physical and chemical characterization of residential oil boiler emissions.

    Science.gov (United States)

    Hays, Michael D; Beck, Lee; Barfield, Pamela; Lavrich, Richard J; Dong, Yuanji; Vander Wal, Randy L

    2008-04-01

    The toxicity of emissions from the combustion of home heating oil coupled with the regional proximity and seasonal use of residential oil boilers (ROB) is an important public health concern. Yet scant physical and chemical information about the emissions from this source is available for climate and air quality modeling and for improving our understanding of aerosol-related human health effects. The gas- and particle-phase emissions from an active ROB firing distillate fuel oil (commonly known as diesel fuel) were evaluated to address this deficiency. Ion chromatography of impactor samples showed that the ultrafine ROB aerosol emissions were approximately 45% (w/w) sulfate. Gas chromatography-mass spectrometry detected various n-alkanes at trace levels, sometimes in accumulation mode particles, and out of phase with the size distributions of aerosol mass and sulfate. The carbonaceous matter in the ROB aerosol was primarily light-adsorbing elemental carbon. Gas chromatography-atomic emission spectroscopy measured a previously unrecognized organosulfur compound group in the ROB aerosol emissions. High-resolution transmission electron microscopy of ROB soot indicated the presence of a highly ordered primary particle nanostructure embedded in larger aggregates. Organic gas emissions were measured using EPA Methods TO-15 and TO-11A. The ROB emitted volatile oxygenates (8 mg/(kg of oil burned)) and olefins (5 mg/(kg of oil burned)) mostly unrelated to the base fuel composition. In the final analysis, the ROB tested was a source of numerous hazardous air pollutants as defined in the Clean Air Act Amendments. Approximations conducted using emissions data from the ROB tests show relatively low contributions to a regional-level anthropogenic emissions inventory for volitile organic compounds, PM2.5, and SO2 mass.

  12. Stereotype threat? Effects of inquiring about test takers' gender on conceptual test performance in physics

    Science.gov (United States)

    Maries, Alexandru; Singh, Chandralekha

    2015-12-01

    It has been found that activation of a stereotype, for example by indicating one's gender before a test, typically alters performance in a way consistent with the stereotype, an effect called "stereotype threat." On a standardized conceptual physics assessment, we found that asking test takers to indicate their gender right before taking the test did not deteriorate performance compared to an equivalent group who did not provide gender information. Although a statistically significant gender gap was present on the standardized test whether or not students indicated their gender, no gender gap was observed on the multiple-choice final exam students took, which included both quantitative and conceptual questions on similar topics.

  13. PHYSICAL CHEMISTRY CHARACTERIZATION OF PRINTED CIRCUIT BOARD OF MOBILE PHONES

    Directory of Open Access Journals (Sweden)

    Hellington Bastos da Silva de Sant’ana

    2015-07-01

    Full Text Available Nowadays, electronics industry is the leading sector in developing new technologies. These new technologies lead to cheaper products increasing the consumption. The lifetime of such products is relatively short and soon it becomes waste, known as electronic waste. Cell phone is a common electronic waste. This waste represents an interesting raw material, because it contains large amount of base metals, considerable amount of valuable metals and also those dangerous. In this work, the electronic waste was submitted to mechanical processing: initially the devices were separated into two categories, as year of release (2002 and disassembled manually. The printed circuit boards were milled below 1 mm and then submitted to density and magnetic separation processes. The fractions obtained during the mechanical processing were characterized by chemical analysis. Using mechanical processing it was possible to obtain metal fractions of 80 wt%. A leaching test was carried out to determine if a waste needs to be managed as a hazardous; so that, cell phone waste must be considered in the category of hazardous residue because the lead concentration was above the limit established by Brazilian Standards

  14. Characterizing the Physical and Thermal Properties of Planetary Regolith at Low Temperatures

    Science.gov (United States)

    Mantovani, James G.; Swanger, Adam; Townsend, Ivan I., III; Sibille, Laurent; Galloway, Gregory

    2014-01-01

    The success or failure of in-situ resource utilization for planetary surface exploration-whether for science, colonization, or commercialization-relies heavily on the design and implementation of systems that can effectively process planetary regolith and exploit its potential benefits. In most cases, this challenge necessarily includes the characterization of regolith properties at low temperatures (cryogenic). None of the nearby solar system destinations of interest, such as the moon, Mars and asteroids, possess a sufficient atmosphere to sustain the consistently "high" surface temperatures found on Earth. Therefore, they can experience permanent cryogenic temperatures or dramatic cyclical changes in surface temperature. Characterization of physical properties (e.g., specific heat, thermal and electrical conductivity) over the entire temperature profile is important when planning a mission to a planetary surface; however, the impact on mechanical properties due to the introduction of icy deposits must also be explored in order to devise effective and robust excavation technologies. The Granular Mechanics and Regolith Operations Laboratory and the Cryogenics Test Laboratory at NASA Kennedy Space Center are developing technologies and experimental methods to address these challenges and to aid in the characterization of the physical and mechanical properties of regolith at cryogenic temperatures. This paper will review the current state of knowledge concerning planetary regolith at low temperature, including that of icy regolith, and describe efforts to manipulate icy regolith through novel penetration and excavation techniques.

  15. Evaluating College Students' Conceptual Knowledge of Modern Physics: Test of Understanding on Concepts of Modern Physics (TUCO-MP)

    Science.gov (United States)

    Akarsu, Bayram

    2011-01-01

    In present paper, we propose a new diagnostic test to measure students' conceptual knowledge of principles of modern physics topics. Over few decades since born of physics education research (PER), many diagnostic instruments that measure students' conceptual understanding of various topics in physics, the earliest tests developed in PER are Force…

  16. Characterization of spent fuel approved testing material: ATM-106

    International Nuclear Information System (INIS)

    Guenther, R.J.; Blahnik, D.E.; Campbell, T.K.; Jenquin, U.P.; Mendel, J.E.; Thornhill, C.K.

    1988-10-01

    The characterization data obtained to date are described for Approved Testing Material (ATM)-106 spent fuel from Assembly BT03 of pressurized-water reactor Calvert Cliffs No. 1. This report is one in a series being prepared by the Materials Characterization Center at Pacific Northwest Laboratory on spent fuel ATMs. The ATMs are receiving extensive examinations to provide a source of well- characterized spent fuel for testing in the US Department of Energy Office of Civilian Radioactive Waste Management (OCWRM) program. ATM-106 consists of 20 full-length irradiated fuel rods with rod-average burnups of about 3700 GJ/kgM (43 MWd/kgM) and expected fission gas release of /approximately/10%. Characterization data include (1) as-fabricated fuel design, irradiation history, and subsequent storage and handling; (2) isotopic gamma scans; (3) fission gas analyses; (4) ceramography of the fuel and metallography of the cladding; (5) calculated nuclide inventories and radioactivities in the fuel and cladding; and (6) radiochemical analyses of the fuel and cladding. Additional analyses of the fuel rod are being conducted and will be included in planned revisions of this report. 12 refs., 110 figs., 81 tabs

  17. Characterization of spent fuel approved testing material---ATM-105

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, R.J.; Blahnik, D.E.; Campbell, T.K.; Jenquin, U.P.; Mendel, J.E.; Thomas, L.E.; Thornhill, C.K.

    1991-12-01

    The characterization data obtained to data are described for Approved Testing Material 105 (ATM-105), which is spent fuel from Bundles CZ346 and CZ348 of the Cooper Nuclear Power Plant, a boiling-water reactor. This report is one in a series being prepared by the Materials Characterization Center at Pacific Northwest Laboratory (PNL) on spent fuel ATMs. The ATMs are receiving extensive examinations to provide a source of well-characterized spent fuel for testing in the US Department of Energy Office of Civilian Radioactive Waste Management (OCRWM) Program. ATM-105 consists of 88 full-length irradiated fuel rods with rod-average burnups of about 2400 GJ/kgM (28 MWd/kgM) and expected fission gas release of about 1%. Characterization data include (1) descriptions of as-fabricated fuel design, irradiation history, and subsequent storage and handling; (2) isotopic gamma scans; (3) fission gas analyses; (4) ceramography of the fuel and metallography of the cladding; (5) special fuel studies involving analytical transmission electron microscopy (AEM); (6) calculated nuclide inventories and radioactivities in the fuel and cladding; and (7) radiochemical analyses of the fuel and cladding. Additional analyses of the fuel are being conducted and will be included in planned revisions of this report.

  18. Nondestructive characterization of ductile cast iron by magnetic adaptive testing

    Czech Academy of Sciences Publication Activity Database

    Vértesy, G.; Uchimoto, T.; Tomáš, Ivan; Takagi, T.

    2010-01-01

    Roč. 322, č. 20 (2010), s. 3117-3121 ISSN 0304-8853 R&D Projects: GA ČR GA101/09/1323; GA AV ČR 1QS100100508 Institutional research plan: CEZ:AV0Z10100520 Keywords : magnetic NDE * magnetic adaptive testing * magnetic hysteresis * cast iron Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.689, year: 2010

  19. An automated test system for terahertz receiver characterization

    Science.gov (United States)

    Kuenzi, Linda C.; Groppi, Christopher E.; Wheeler, Caleb H.; Mani, Hamdi

    2014-07-01

    An automated test system was developed to characterize detectors for the Kilopixel Array Pathfinder Project (KAPPa), a 16-pixel 2D integrated heterodyne focal plane array. Although primarily designed for KAPPa, the system can be used with other instruments to automate tests that might be tedious and time-consuming by hand. Mechanical components include an adjustable structure of aluminum t-slot framing that supports a rotating chopper. Driven by a stepper motor, the wheel alternates between blackbodies at room temperature and 77 K. The cold load consists of absorbing material submerged in liquid nitrogen in an open Styrofoam cooler. Python scripts control the mechanical system, interface with receiver components, and process data. Test system operation was verified by sweeping the local oscillator frequency with a Virginia Diodes room temperature receiver. The system was then integrated with the KAPPa receiver to allow complete and automated testing of all array pixels with minimal user intervention.

  20. Clinician-Friendly Physical Performance Tests for the Knee.

    Science.gov (United States)

    Harrison, Jerrod J; Yorgey, Marissa K; Csiernik, Alexander J; Vogler, Joseph H; Games, Kenneth E

    2017-11-01

    Reference:  Hegedus EJ, McDonough S, Bleakley C, Cook CE, Baxter GD. Clinician-friendly lower extremity physical performance measures in athletes: a systematic review of measurement properties and correlation with injury. Part 1: the tests for knee function including the hop tests. Br J Sports Med. 2015;49(10):642-648.   Do individual physical performance tests (PPTs) used as measures for lower extremity function have any relationship to injuries in athletes aged 12 years or older?   Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used to locate articles. The authors searched PubMed, EMBASE, and SPORTDiscus, in addition to searching by hand. The search strategy combined the terms athlete, lower extremity, and synonyms of performance test with the names of performance tests.   Studies were included if they involved a test that met the operational definition for a PPT. The included studies assessed components of sport function (eg, speed, agility, and power), determined readiness for return to sport, or predicted injury to the lower extremity. All PPT measures could be performed on the field, courtside, or in a gym with affordable, portable, and readily available equipment. Studies were excluded if they made use of 3-dimensional motion capture, force platforms, timing gates, treadmills, stationary bikes, metabolic charts, or another nonportable, costly testing device. Athletes were categorized on the Tegner Scale at a minimum of level 5, which is the lowest level that still encompasses competitive athletes. Studies were included if 50% or more of the participants were rated above 5 on the Tegner Scale. Studies were excluded if the sole purpose was to judge movement quality or range of motion. Studies were selected if they identified the knee or a knee injury as a focal point of the paper.   The Consensus-Based Standards for the Selection of Health Measurement Instruments (COSMIN) was used to critique the

  1. Effect of bismuth oxide on white mineral trioxide aggregate: chemical characterization and physical properties.

    Science.gov (United States)

    Grazziotin-Soares, R; Nekoofar, M H; Davies, T E; Bafail, A; Alhaddar, E; Hübler, R; Busato, A L S; Dummer, P M H

    2014-06-01

    To assess the effect of bismuth oxide (Bi2 O3 ) on the chemical characterization and physical properties of White mineral trioxide aggregate (MTA) Angelus. Commercially available White MTA Angelus and White MTA Angelus without Bi2 O3 provided by the manufacturer especially for this study were subjected to the following tests: Rietveld X-ray diffraction analysis (XRD), energy-dispersive X-ray analysis (EDX), scanning electron microscopy (SEM), compressive strength, Vickers microhardness test and setting time. Chemical analysis data were reported descriptively, and physical properties were expressed as means and standard deviations. Data were analysed using Student's t-test and Mann-Whitney U test (P = 0.05). Calcium silicate peaks were reduced in the diffractograms of both hydrated materials. Bismuth particles were found on the surface of White MTA Angelus, and a greater amount of particles characterized as calcium hydroxide was observed by visual examination on White MTA without Bi2 O3 . The material without Bi2 O3 had the shortest final setting time (38.33 min, P = 0.002), the highest Vickers microhardness mean value (72.35 MPa, P = 0.000) and similar compressive strength results (P = 0.329) when compared with the commercially available White MTA Angelus containing Bi2 O3 . The lack of Bi2 O3 was associated with an increase in Vickers microhardness, a reduction in final setting time, absence of Bi2 O3 peaks in diffractograms, as well as a large amount of calcium and a morphology characteristic of calcium hydroxide in EDX/SEM analysis. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  2. Feasibility and Reliability of Physical Fitness Tests in Older Adults with Intellectual Disability: A Pilot Study

    Science.gov (United States)

    Hilgenkamp, Thessa I. M.; van Wijck, Ruud; Evenhuis, Heleen M.

    2012-01-01

    Background: Physical fitness is relevant for wellbeing and health, but knowledge on the feasibility and reliability of instruments to measure physical fitness for older adults with intellectual disability is lacking. Methods: Feasibility and test-retest reliability of a physical fitness test battery (Box and Block Test, Response Time Test, walking…

  3. 40 CFR 160.135 - Physical and chemical characterization studies.

    Science.gov (United States)

    2010-07-01

    ...) PESTICIDE PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Protocol for and Conduct of a Study § 160.135 Physical... partition coefficient, volatility, and persistence (such as biodegradation, photodegradation, and chemical...

  4. Tests of the standard model and searches for new physics

    Energy Technology Data Exchange (ETDEWEB)

    Langacker, Paul [Pennsylvania Univ., PA (United States). Dept. of Physics

    1996-07-01

    Earlier chapters of this volume have detailed described the standard model and its renormalization, the various types of precision experiments, and their implications. This chapter is devoted to global analysis of the Z-pole, M{sub W}, and neutral current data, which contains more information that any one class of experiments. The subsequent sections will summarize some of the relevant data and theoretical formulas, the status of the standard model tests and parameter determinations, the possible classes of new physics, and the implications of the precision experiments. In particular, the model independent analysis of neutral current couplings, which establishes the standard model to first approximation; the implication of supersymmetry; supersymmetric grand unification; and a number if specific types of new physics, including heavy Z{sup '} bosons, new sources of SU{sub 2} breaking, new contributions to the gauge boson self-energies, Zb b-bar vertex corrections, certain types of new 4-Fermi operators and leptoquarks, and the exotic fermions are described.

  5. Medical Physics: Forming and testing solutions to clinical problems.

    Science.gov (United States)

    Tsapaki, Virginia; Bayford, Richard

    2015-11-01

    According to the European Federation of Organizations for Medical Physics (EFOMP) policy statement No. 13, "The rapid advance in the use of highly sophisticated equipment and procedures in the medical field increasingly depends on information and communication technology. In spite of the fact that the safety and quality of such technology is vigorously tested before it is placed on the market, it often turns out that the safety and quality is not sufficient when used under hospital working conditions. To improve safety and quality for patient and users, additional safeguards and related monitoring, as well as measures to enhance quality, are required. Furthermore a large number of accidents and incidents happen every year in hospitals and as a consequence a number of patients die or are injured. Medical Physicists are well positioned to contribute towards preventing these kinds of events". The newest developments related to this increasingly important medical speciality were presented during the 8th European Conference of Medical Physics 2014 which was held in Athens, 11-13 September 2014 and hosted by the Hellenic Association of Medical Physicists (HAMP) in collaboration with the EFOMP and are summarized in this issue. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  6. Characterization of persistent postoperative pain by quantitative sensory testing

    DEFF Research Database (Denmark)

    Werner, Mads U.; Kehlet, Henrik

    2010-01-01

    of the sensory system either by mechanical, thermal or electrical stimuli, with assessment of the evoked psychophysical response. QST has been used in prospective assessments of how and why some individuals develop persistent postoperative pain. This comprehensive review describes, first, QST as a predictive......Postoperative pain remains inadequately treated, and it has been estimated that 5-10% undergoing surgery will develop moderate to severe persistent pain leading to chronic physical disability and psychosocial distress. Quantitative sensory testing (QST) is a graded, standardized activation...

  7. Pre-flight physical simulation test of HIMES reentry test vehicle

    Science.gov (United States)

    Kawaguchi, Jun'ichiro; Inatani, Yoshifumi; Yonemoto, Koichi; Hosokawa, Shigeru

    ISAS is now developing a small reentry test vehicle, which is 2m long with a 1.5m wing span and weighs about 170 kg, for the purpose of exploring high angle-of-attack aerodynamic attitude control issue in supersonic and hypersonic speed. The flight test, employing 'Rockoon' launch system, is planned as a preliminary design verification for a fully reusable winged rocket named HIMES (Highly Maneuverable Experimental Space) vehicle. This paper describes the results of preflight ground test using a motion table system. This ground system test is called 'physical simulation' aimed at: (1) functional verification of side-jet system, aerodynamic surface actuators, battery and onboard avionics; and (2) guidance and control law evaluation, in total hardware-in-the-loop system. The pressure of side-jet nozzles was measured to provide exact thrust characteristics of reaction control. The dynamics of vehicle motion was calculated in real-time by the ground simulation computer.

  8. Mechanical Characterization and Corrosion Testing of X608 Al Alloy

    Energy Technology Data Exchange (ETDEWEB)

    Prabhakaran, Ramprashad; Choi, Jung-Pyung; Stephens, Elizabeth V.; Catalini, David; Lavender, Curt A.; Rohatgi, Aashish

    2016-02-07

    This paper describes the mechanical characterization and corrosion testing of X608 Al alloy that is being considered for A-pillar covers for heavy-duty truck applications. Recently, PNNL developed a thermo-mechanical process to stamp A-pillar covers at room temperature using this alloy, and the full-size prototype was successfully stamped by a tier-1 supplier. This study was conducted to obtain additional important information related to the newly developed forming process, and to further improve its mechanical properties. The solutionization temperature, pre-strain and paint-bake heat-treatment were found to influence the alloy’s fabricability and mechanical properties. Natural aging effect on the formability was investigated by limiting dome height (LDH) tests. Preliminary corrosion experiments showed that the employed thermo-mechanical treatments did not significantly affect the corrosion behavior of Al X608.

  9. Physical characterization of coffee after roasting and grinding

    Directory of Open Access Journals (Sweden)

    Gabriel Henrique Horta de Oliveira

    2014-09-01

    Full Text Available Flowability is an important characteristic of handling process for efficiency and reliability purpose of post-harvest operations, which are governed by the physical properties of the product. Physical properties determination is an important factor for formulation of machinery projects and sizing of post-harvest operations, which may impact considerably on the products quality, influencing directly the operation cost and company profit. Thus, the objective of this work was to evaluate and determinate some physical properties (repose angle, unit and bulk density, porosity and color coordinates, particle size, moisture content, water activity, angle of internal friction and effective angle of internal friction of coffee, such as to evaluate the influence of different roast and grinding degrees over these properties. Crude grain coffee (Coffea canephora and Coffea arabica, dehulled and dried were used. These were roasted at two levels: medium light and medium-dark brown, which Agtron numbers are, respectively, SCAA#65 and SCAA#45. After roasting process, grains were grinded at three particle sizes (thin, medium and thick. Both particle size and roast degree significantly affected physical properties of coffee. Coffee samples roasted at medium dark level obtained lower values of moisture content, water activity, repose angle, bulk and real density. Coffee samples grinded at level thin presented an increase of angle of internal friction and effective angle of internal friction, repose angle, bulk and real density, porosity and decrease of water activity values.

  10. The spin-valve transistor: Fabrication, characterization and physics

    NARCIS (Netherlands)

    Jansen, R.; van 't Erve, O.M.J.; Kim, S.D.; Vlutters, R.; Anil Kumar, P.S.; Lodder, J.C.

    2001-01-01

    An overview is given of the fabrication, basic properties, and physics of the spin-valve transistor. We describe the layout of this three-terminal ferromagnet/semiconductor hybrid device, as well as the operating principle. Fabrication technologies are discussed, including vacuum metal bonding. We

  11. Characterization and Physics-Based Modeling of Electrochemical Memristors

    Science.gov (United States)

    2015-11-16

    physics of photodoping in ChG materials remain unsolved. For example, the electro- chemistry of photodoping is still not fully understood and accurate... sleep period, the flip flop goes through two phases in order to restore the stored data – Precharge phase followed by Read/Restore phase. During

  12. Characterization of physical and aerodynamic properties of walnuts

    Science.gov (United States)

    The objective of this research was to study the physical and aerodynamic properties of freshly harvested walnuts. Measurements were carried out for three walnut varieties, Tulare, Howard and Chandler cultivated in California, USA. The nuts treated with and without Ethephon were collected from mechan...

  13. Characterization, Leaching, and Filtration Testing for Tributyl Phosphate (TBP, Group 7) Actual Waste Sample Composites

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, Matthew K.; Billing, Justin M.; Blanchard, David L.; Buck, Edgar C.; Casella, Amanda J.; Casella, Andrew M.; Crum, J. V.; Daniel, Richard C.; Draper, Kathryn E.; Fiskum, Sandra K.; Jagoda, Lynette K.; Jenson, Evan D.; Kozelisky, Anne E.; MacFarlan, Paul J.; Peterson, Reid A.; Shimskey, Rick W.; Snow, Lanee A.; Swoboda, Robert G.

    2009-03-09

    .A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. The actual waste-testing program included homogenizing the samples by group, characterizing the solids and aqueous phases, and performing parametric leaching tests. The tributyl phosphate sludge (TBP, Group 7) is the subject of this report. The Group 7 waste was anticipated to be high in phosphorus as well as aluminum in the form of gibbsite. Both are believed to exist in sufficient quantities in the Group 7 waste to address leaching behavior. Thus, the focus of the Group 7 testing was on the removal of both P and Al. The waste-type definition, archived sample conditions, homogenization activities, characterization (physical, chemical, radioisotope, and crystal habit), and caustic leaching behavior as functions of time, temperature, and hydroxide concentration are discussed in this report. Testing was conducted according to TP-RPP-WTP-467.

  14. Physical and chemical characterization of particles in producer gas

    DEFF Research Database (Denmark)

    Hindsgaul, Claus; Henriksen, Ulrik B.; Bentzen, Jens Dall

    2000-01-01

    Particles in the gas from a two-stage (separate pyrolysis and gasification) down-draft biomass gasifier were collected and characterized. Their concentration, geometries and chemical compositions were investigated. Special attention was given to features suspected to harm internal combustion (IC...

  15. Physical and chemical characterization of acid tar waste from crude ...

    African Journals Online (AJOL)

    In the present investigation gas chromatography/mass spectrometry (GC/MS), fourier transform infrared (FTIR), inductively coupled plasma/atomic emission spectrometry (ICP/AES), scanning electron microscopy with energy dispersive Xray (SEM/EDX) were mainly used to characterize the acid tar waste from crude benzol ...

  16. Genetic diversity and molecular characterization of physic nut ...

    African Journals Online (AJOL)

    ... were used to characterize toxicity alleles, and none of the accessions presented patterns characteristic of non-toxic accessions. Keywords: Jatropha curcas, inter-simple sequence repeat (ISSR), random amplified polymorphic DNA (RAPD), microsatellites, toxicity. African Journal of Biotechnology Vol. 12(9), pp. 907-913 ...

  17. Extraction, structural and physical characterization of type I collagen ...

    African Journals Online (AJOL)

    The acid soluble collagen (ASC) and pepsin soluble collagen (PSC) were extracted from the outer skin of Sepiella inermis and further characterized partially. The yield of ASC was low (0.58% on dry weight basis); whereas the yield of PSC was comparatively more (16.23% on dry weight basis). The protein content in ASC ...

  18. Physical Training Outcome Predictions With Biomechanics, Part I: Army Physical Fitness Test Modeling.

    Science.gov (United States)

    Sih, Bryant L; Negus, Charles H

    2016-05-01

    The U.S. Army Basic Combat Training (BCT) is the first step in preparing soldier trainees for the physical demands of the military. Unfortunately, a substantial number of trainees fail BCT due to failure on the final Army Physical Fitness Test (also known as the "end of cycle" APFT). Current epidemiological studies have used statistics to identify several risk factors for poor APFT performance, but these studies have had limited utility for guiding regimen design to maximize APFT outcome. This is because such studies focus on intrinsic risks to APFT failure and do not utilize detailed BCT activity data to build models which offer guidance for optimizing the training regimen to improve graduation rates. In this study, a phenomenological run performance model that accounts for physiological changes in fitness and fatigue due to training was applied to recruits undergoing U.S. Army BCT using high resolution (minute-by-minute) activity data. The phenomenological model was better at predicting both the final as well as intermediate APFTs (R(2) range = 0.55-0.59) compared to linear regression models (LRMs) that used the same intrinsic input variables (R(2) range = 0.36-0.50). Unlike a statistical approach, a phenomenological model accounts for physiological changes and, therefore, has the potential to not only identify trainees at risk of failing BCT on novel training regimens, but offer guidance to regimen planners on how to change the regimen for maximizing physical performance. This paper is Part I of a 2-part series on physical training outcome predictions. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  19. An empirical analysis of the physical aptitude exam as a predictor of performance on the Physical Readiness Test

    OpenAIRE

    Patrick, Robert W.

    2000-01-01

    The Physical Aptitude Exam, administered to candidates in the Naval Academy admissions process to measure physical aptitude, consists of pullups for men or the flexed arm hang for women, a 300-yard shuttle run, a standing longiump, and a kneeling basketball throw. The Physical Readiness Test, administered semi-annually to all naval personnel including midshipmen, consists of modified situps, pushups, and a 1.5-mile run. The purpose of this research is to determine if the Physical Aptitude Exa...

  20. Physical and Chemical Characterization of Poly(hexamethylene biguanide Hydrochloride

    Directory of Open Access Journals (Sweden)

    Luiz Henrique C. Mattoso

    2011-06-01

    Full Text Available We present the characterization of commercially available Poly(hexamethylene biguanide hydrochloride (PHMB, a polymer with biocidal activity and several interesting properties that make this material suitable as a building block for supramolecular chemistry and “smart” materials. We studied polymer structure in water solution by dynamic light scattering, surface tension and capacitance spectroscopy. It shows typical surfactant behavior due to amphiphilic structure and low molecular weight. Spectroscopic (UV/Vis, FT-NIR and thermal characterization (differential scanning calorimetry, DSC, and thermogravimetric analysis, TGA were performed to give additional insight into the material structure in solution and solid state. These results can be the foundation for more detailed investigations on usefulness of PHMB in new complex materials and devices.

  1. Review of Physical and Chemical Methods for Characterization of Fuels

    Science.gov (United States)

    1981-12-01

    benzenes, indans, tetralins, indenes , naphtalenes, and tricyclic aromatics in middle distillates. LIMITATIONS: The given precision data may not be...University, Norfolk, VA, Analytical Chemistry, Vol. 53, No. 2, pp 197-201, February 1981. S-042: Application of FTIR detection to the size separation of... FTIR is advantageous over conventional dispersive methods for the characterization of highly adsorbing materials. Benzene- and pyridine-solubles are

  2. Characterization of Material Response During Arc-Jet Testing with Optical Methods Status and Perspectives

    Science.gov (United States)

    Winter, Michael

    2012-01-01

    The characterization of ablation and recession of heat shield materials during arc jet testing is an important step towards understanding the governing processes during these tests and therefore for a successful extrapolation of ground test data to flight. The behavior of ablative heat shield materials in a ground-based arc jet facility is usually monitored through measurement of temperature distributions (across the surface and in-depth), and through measurement of the final surface recession. These measurements are then used to calibrate/validate materials thermal response codes, which have mathematical models with reasonably good fidelity to the physics and chemistry of ablation, and codes thus calibrated are used for predicting material behavior in flight environments. However, these thermal measurements only indirectly characterize the pyrolysis processes within an ablative material pyrolysis is the main effect during ablation. Quantification of pyrolysis chemistry would therefore provide more definitive and useful data for validation of the material response codes. Information of the chemical products of ablation, to various levels of detail, can be obtained using optical methods. Suitable optical methods to measure the shape and composition of these layers (with emphasis on the blowing layer) during arc jet testing are: 1) optical emission spectroscopy (OES) 2) filtered imaging 3) laser induced fluorescence (LIF) and 4) absorption spectroscopy. Several attempts have been made to optically measure the material response of ablative materials during arc-jet testing. Most recently, NH and OH have been identified in the boundary layer of a PICA ablator. These species are suitable candidates for a detection through PLIF which would enable a spatially-resolved characterization of the blowing layer in terms of both its shape and composition. The recent emission spectroscopy data will be presented and future experiments for a qualitative and quantitative

  3. Integrating borehole logs and aquifer tests in aquifer characterization

    Science.gov (United States)

    Paillet, Frederick L.; Reese, R.S.

    2000-01-01

    Integration of lithologic logs, geophysical logs, and hydraulic tests is critical in characterizing heterogeneous aquifers. Typically only a limited number of aquifer tests can be performed, and these need to be designed to provide hydraulic properties for the principle aquifers in the system. This study describes the integration of logs and aquifer tests in the development of a hydrostratigraphic model for the surficial aquifer system in and around Big Cypress National Preserve in eastern Collier County, Florida. Borehole flowmeter tests provide qualitative permeability profiles in most of 26 boreholes drilled in the Study area. Flow logs indicate the depth of transmissive units, which are correlated across the study area. Comparison to published studies in adjacent areas indicates that the main limestone aquifer of the 000000Tamiami Formation in the study area corresponds with the gray limestone aquifer in western Dade County and the water table and lower Tamiami Aquifer in western Collier County. Four strategically located, multiwell aquifer tests are used to quantify the qualitative permeability profiles provided by the flowmeter log analysis. The hydrostratigraphic model based on these results defines the main aquifer in the central part of the study area as unconfined to semiconfined with a transmissivity as high as 30,000 m2/day. The aquifer decreases in transmissivity to less than 10,000 m2/day in some parts of western Collier County, and becomes confined to the east and northeast of the study area, where transmissivity decreases to below 5000 m2/day.Integration of lithologic logs, geophysical logs, and hydraulic tests is critical in characterizing heterogeneous aquifers. Typically only a limited number of aquifer tests can be performed, and these need to be designed to provide hydraulic properties for the principle aquifers in the system. This study describes the integration of logs and aquifer tests in the development of a hydrostratigraphic model for the

  4. Produção de brotos de soja utilizando a cultivar BRS 216: caracterização físico-química e teste de aceitabilidade Production of soybean sprouts from the cultivar BRS 216: physical and chemical characterization and acceptability test

    Directory of Open Access Journals (Sweden)

    Marcelo Alvares de Oliveira

    2013-03-01

    Full Text Available O presente trabalho teve por objetivo avaliar os parâmetros físico-químicos e os processos para a produção de brotos de soja a partir de sementes da cultivar BRS 216, bem como sua composição química e aceitabilidade. Foram avaliados o comprimento e o peso dos brotos viáveis, a composição centesimal e os teores de isoflavonas e de inibidor de tripsina. O desenho experimental foi ao acaso com três repetições e os tratamentos foram avaliados num esquema fatorial 3 × 3: três frequências de irrigação (a cada quatro, oito e 12 horas e três períodos de crescimento (cinco, seis e sete dias. O teste de aceitabilidade dos brotos de soja foi realizado utilizando-se a escala hedônica estruturada de nove pontos, avaliando-se cor, aparência, odor, textura, sabor e avaliação global, além da intenção de compra. A frequência de irrigação com intervalos de quatro horas e o período de sete dias de crescimento foram ideais para produção dos brotos de soja, favorecendo maior produtividade, teores mais elevados de proteínas e menores teores de inibidor de tripsina. O índice de aceitabilidade dos brotos de soja foi superior a 70 em todas as características avaliadas, com exceção do odor.The aim of the present study was to evaluate the physical and chemical parameters and process for the production of soybean sprouts from the BRS 216 cultivar, as well as determining their chemical composition and acceptability. The length and weight of viable sprouts, proximate composition, and the isoflavone and trypsin inhibitor contents were evaluated. The experimental design was completely randomized with three replications, and the treatments were evaluated using a 3 × 3 factorial design: three irrigation frequencies (four, eight and 12 hours and three growth periods (five, six and seven days. The soybean sprout acceptability was determined using a nine point structured hedonic scale, evaluating colour, appearance, aroma, texture, flavour

  5. Characterization of persistent postoperative pain by quantitative sensory testing

    DEFF Research Database (Denmark)

    Werner, Mads U.; Kehlet, Henrik

    2010-01-01

    Postoperative pain remains inadequately treated, and it has been estimated that 5-10% undergoing surgery will develop moderate to severe persistent pain leading to chronic physical disability and psychosocial distress. Quantitative sensory testing (QST) is a graded, standardized activation...... research tool in studies investigating the correlation between responses to preoperatively applied experimental pain stimuli and clinical postoperative pain. Second, the use of QST as a valuable prognostic, sequential assessment tool in surgical procedure specific research is presented. Third......, the implications of these findings for use of QST in future research are discussed. More rational design of predictive studies in PPP, based on surgical procedure specific approaches, is needed in order to improve our understanding of prevention and management of this debilitating postsurgical condition....

  6. Characterization of persistent postoperative pain by quantitative sensory testing

    DEFF Research Database (Denmark)

    Werner, Mads U.; Kehlet, Henrik

    2010-01-01

    , the implications of these findings for use of QST in future research are discussed. More rational design of predictive studies in PPP, based on surgical procedure specific approaches, is needed in order to improve our understanding of prevention and management of this debilitating postsurgical condition.......Postoperative pain remains inadequately treated, and it has been estimated that 5-10% undergoing surgery will develop moderate to severe persistent pain leading to chronic physical disability and psychosocial distress. Quantitative sensory testing (QST) is a graded, standardized activation...... research tool in studies investigating the correlation between responses to preoperatively applied experimental pain stimuli and clinical postoperative pain. Second, the use of QST as a valuable prognostic, sequential assessment tool in surgical procedure specific research is presented. Third...

  7. Nanoparticles for intravascular applications: physicochemical characterization and cytotoxicity testing.

    Science.gov (United States)

    Matuszak, Jasmin; Baumgartner, Jens; Zaloga, Jan; Juenet, Maya; da Silva, Acarília Eduardo; Franke, Danielle; Almer, Gunter; Texier, Isabelle; Faivre, Damien; Metselaar, Josbert M; Navarro, Fabrice P; Chauvierre, Cédric; Prassl, Ruth; Dézsi, László; Urbanics, Rudolf; Alexiou, Christoph; Mangge, Harald; Szebeni, János; Letourneur, Didier; Cicha, Iwona

    2016-03-01

    We report the physicochemical analysis of nanosystems intended for cardiovascular applications and their toxicological characterization in static and dynamic cell culture conditions. Size, polydispersity and ζ-potential were determined in 10 nanoparticle systems including liposomes, lipid nanoparticles, polymeric and iron oxide nanoparticles. Nanoparticle effects on primary human endothelial cell viability were monitored using real-time cell analysis and live-cell microscopy in static conditions, and in a flow model of arterial bifurcations. The majority of tested nanosystems were well tolerated by endothelial cells up to the concentration of 100 μg/ml in static, and up to 400 μg/ml in dynamic conditions. Pilot experiments in a pig model showed that intravenous administration of liposomal nanoparticles did not evoke the hypersensitivity reaction. These findings are of importance for future clinical use of nanosystems intended for intravascular applications.

  8. Development of Power Electronics Based Test Platform for Characterization and Testing of Magnetocaloric Materials

    Directory of Open Access Journals (Sweden)

    Deepak Elamalayil Soman

    2015-01-01

    Full Text Available Magnetocaloric effects of various materials are getting more and more interesting for the future, as they can significantly contribute towards improving the efficiency of many energy intensive applications such as refrigeration, heating, and air conditioning. Accurate characterization of magnetocaloric effects, exhibited by various materials, is an important process for further studies and development of the suitable magnetocaloric heating and cooling solutions. The conventional test facilities have plenty of limitations, as they focus only on the thermodynamic side and use magnetic machines with moving bed of magnetocaloric material or magnet. In this work an entirely new approach for characterization of the magnetocaloric materials is presented, with the main focus on a flexible and efficient power electronic based excitation and a completely static test platform. It can generate a periodically varying magnetic field using superposition of an ac and a dc magnetic field. The scale down prototype uses a customized single phase H-bridge inverter with essential protections and an electromagnet load as actuator. The preliminary simulation and experimental results show good agreement and support the usage of the power electronic test platform for characterizing magnetocaloric materials.

  9. Test on the reactor with the portable digital reactivity meter for physical experiment

    International Nuclear Information System (INIS)

    Huang Liyuan

    2010-01-01

    Test must be performed on the zero power reactor During the development of portable digital reactivity meter for physical experiment, in order to check its measurement function and accuracy. It describes the test facility, test core, test methods, test items and test results. The test results show that the instrument satisfy the requirements of technical specification, and satisfy the reactivity measurement in the physical experiments on reactors. (authors)

  10. Differences in gender performance on competitive physics selection tests

    OpenAIRE

    Kate Wilson; David Low; Matthew Verdon; Alix Verdon

    2016-01-01

    [This paper is part of the Focused Collection on Gender in Physics.] We have investigated gender differences in performance over the past eight years on the Australian Science Olympiad Exam (ASOE) for physics, which is taken by nearly 1000 high school students each year. The ASOE, run by Australian Science Innovations (ASI), is the initial stage of the process of selection of teams to represent Australia at the Asian and International Physics Olympiads. Students taking the exam are generally ...

  11. TESTING AND CHARACTERIZATION OF ENGINEERED FORMS OF MONOSODIUM TITANATE (MST)

    Energy Technology Data Exchange (ETDEWEB)

    Taylor-Pashow, K.; Nash, C.; Hobbs, D.

    2012-05-14

    Engineered forms of MST and mMST were prepared at ORNL using an internal gelation process. Samples of these two materials were characterized at SRNL to examine particle size and morphology, peroxide content, tapped densities, and Na, Ti, and C content. Batch contact tests were also performed to examine the performance of the materials. The {sup E}mMST material was found to contain less than 10% of the peroxide found in a freshly prepared batch of mMST. This was also evidenced in batch contact testing with both simulated and actual waste, where little difference in performance was seen between the two engineered materials, {sup E}MST and {sup E}mMST. Based on these results, attempts were made to increase the peroxide content of the materials by post-treatment with hydrogen peroxide. The peroxide treatment resulted in a slight ({approx}10%) increase in peroxide content; however, the peroxide:Ti molar ratio was still much lower ({approx}0.1 X) than what is seen in a freshly prepared batch of mMST. Testing with simulated waste showed the performance of the peroxide treated materials was improved. Batch contact tests were also performed with an earlier (2003) prepared lot of {sup E}MST to examine the effect of ionic strength on the performance of the material. In general the results showed a decrease in removal performance with increasing ionic strength, which is consistent with previous testing with MST. A Sr loading isotherm was also determined, and the {sup E}MST material was found to reach a Sr loading as high as 13.2 wt % after 100 days of contact at a phase ratio of 20000 mL/g. At the typical MST phase ratio of 2500 mL/g (0.4 g/L), a Sr loading of 2.64 wt % was reached after 506 hours of contact. Samples of {sup E}MST and the post-peroxide treated {sup E}mMST were also tested in a column configuration using simulated waste solution. The breakthrough curves along with analysis of the sorbent beds at the conclusion of the experiments showed that the peroxide treated

  12. The physical performance test predicts aerobic capacity sufficient for independence in early-stage Alzheimer disease.

    Science.gov (United States)

    Vidoni, Eric D; Billinger, Sandra A; Lee, Charesa; Hamilton, Jenna; Burns, Jeffrey M

    2012-01-01

    Early identification of physical impairment related to Alzheimer disease (AD) is increasingly identified as an important aspect of diagnosis and care. Clinically accessible tools for evaluating physical capacity and impairment in AD have been developed but require further characterization for their effective use. To assess the utility of the Physical Performance Test (PPT) for identifying functionally limiting aerobic capacity in older adults with AD and without dementia. Secondary analysis of a dataset of community dwelling older adults, 70 without dementia and 60 with early-stage AD. Participants were administered the PPT and performed a graded maximal exercise test. The clinical utility of 2 versions of the PPT was described by determining sensitivity and specificity to functionally limiting aerobic capacity. The 9-item PPT is predictive of diminished aerobic capacity in older adults with AD. A score of 28 or less indicates likelihood of functionally limiting aerobic capacity that would limit independent function with 67% sensitivity and 67% specificity. The 4-item mini-PPT demonstrates improved capability for identifying impaired functional aerobic capacity with 85% sensitivity and 62% specificity. The PPT was not useful for identifying impaired functional aerobic capacity in older adults without dementia. The PPT, which incorporates basic and instrumental activities of daily living as test items, and the mini-PPT which focuses on basic activities of daily living and simple physical functions, are both clinically useful tool for the evaluation for individuals in the earliest stages of AD and both provide important information about functional performance. The mini-PPT additionally inform the clinician as to whether or not individual with early-stage AD is likely to have insufficient aerobic capacity to perform instrumental daily functions.

  13. Advanced techniques for the chemical and physical characterization of beryllia

    International Nuclear Information System (INIS)

    Sims, T.D.; Jech, D.E.; Sepulveda, J.L.

    1991-01-01

    As performance demands for beryllia increase, so will the need for tools to adequately characterize various properties of this ceramic. Analytical techniques have emerged or are currently being adapted to reveal the surface chemical composition and electrical and thermal properties. This paper discusses the application of Secondary Ion Mass Spectrometry (SIMS), X-Ray Photoelectron Spectroscopy (XPS), and chemical imaging by windowless SEM/EDS to BeO ceramics. The use of SIMS has revealed extremely low levels of surface impurities which could not be detected by SEM/EDS or Auger. XPS has been applied in a study of gold adhesion on nickel-plated BeO substrates. Windowless EDS was used for determining the sintering aid dispersion by chemical mapping. Advanced techniques for geometrically independent measurements of dielectric constant, loss tangent and thermal conductivity are reviewed

  14. Commissioning experience and beam physics measurements at the SwissFEL Injector Test Facility

    Directory of Open Access Journals (Sweden)

    T. Schietinger

    2016-10-01

    Full Text Available The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and test bed for the development and realization of SwissFEL, the x-ray Free-Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chicane and a diagnostic section including a transverse deflecting rf cavity. It delivered electron bunches of up to 200 pC charge and up to 250 MeV beam energy at a repetition rate of 10 Hz. The measurements performed at the test facility not only demonstrated the beam parameters required to drive the first stage of an FEL facility, but also led to significant advances in instrumentation technologies, beam characterization methods and the generation, transport and compression of ultralow-emittance beams. We give a comprehensive overview of the commissioning experience of the principal subsystems and the beam physics measurements performed during the operation of the test facility, including the results of the test of an in-vacuum undulator prototype generating radiation in the vacuum ultraviolet and optical range.

  15. Apps for Physical Education: Teacher Tested, Kid Approved!

    Science.gov (United States)

    Phillips, Amber; Rodenbeck, Myshel; Clegg, Bethany

    2014-01-01

    Physical education teachers have been encouraged to use technology in their classes to enhance student motivation and learning. The purpose of this article is to share iOS applications (apps) that K-12 physical education teachers and students have found useful.

  16. Development and Testing of the Observational System for Recording Physical Activity in Children: Elementary School

    Science.gov (United States)

    McIver, Kerry L.; Brown, William H.; Pfeiffer, Karin A.; Dowda, Marsha; Pate, Russell R.

    2016-01-01

    Purpose: This study describes the development and pilot testing of the Observational System for Recording Physical Activity-Elementary School (OSRAC-E) Version. Method: This system was developed to observe and document the levels and types of physical activity and physical and social contexts of physical activity in elementary school students…

  17. Prevalence and Correlates of Physical Fitness Testing in U.S. Schools--2000

    Science.gov (United States)

    Morrow, James R., Jr.; Fulton, Janet E.; Brener, Nancy D.; Kohl, Harold W., III

    2008-01-01

    Because of the perceived lack of youth physical fitness and/or concerns for increased obesity, physical education teachers are interested in youth fitness and physical activity levels. Statewide mandates are being developed that require school-based teachers to complete physical fitness testing. Data from the nationally representative School…

  18. Statewide Physical Fitness Testing: A BIG Waist or a BIG Waste?

    Science.gov (United States)

    Morrow, James R., Jr.; Ede, Alison

    2009-01-01

    Statewide physical fitness testing is gaining popularity in the United States because of increased childhood obesity levels, the relations between physical fitness and academic performance, and the hypothesized relations between adult characteristics and childhood physical activity, physical fitness, and health behaviors. Large-scale physical…

  19. Physical characterization of functionalized spider silk: electronic and sensing properties

    Directory of Open Access Journals (Sweden)

    Eden Steven, Jin Gyu Park, Anant Paravastu, Elsa Branco Lopes, James S Brooks, Ongi Englander, Theo Siegrist, Papatya Kaner and Rufina G Alamo

    2011-01-01

    Full Text Available This work explores functional, fundamental and applied aspects of naturally harvested spider silk fibers. Natural silk is a protein polymer where different amino acids control the physical properties of fibroin bundles, producing, for example, combinations of β-sheet (crystalline and amorphous (helical structural regions. This complexity presents opportunities for functional modification to obtain new types of material properties. Electrical conductivity is the starting point of this investigation, where the insulating nature of neat silk under ambient conditions is described first. Modification of the conductivity by humidity, exposure to polar solvents, iodine doping, pyrolization and deposition of a thin metallic film are explored next. The conductivity increases exponentially with relative humidity and/or solvent, whereas only an incremental increase occurs after iodine doping. In contrast, iodine doping, optimal at 70 °C, has a strong effect on the morphology of silk bundles (increasing their size, on the process of pyrolization (suppressing mass loss rates and on the resulting carbonized fiber structure (that becomes more robust against bending and strain. The effects of iodine doping and other functional parameters (vacuum and thin film coating motivated an investigation with magic angle spinning nuclear magnetic resonance (MAS-NMR to monitor doping-induced changes in the amino acid-protein backbone signature. MAS-NMR revealed a moderate effect of iodine on the helical and β-sheet structures, and a lesser effect of gold sputtering. The effects of iodine doping were further probed by Fourier transform infrared (FTIR spectroscopy, revealing a partial transformation of β-sheet-to-amorphous constituency. A model is proposed, based on the findings from the MAS-NMR and FTIR, which involves iodine-induced changes in the silk fibroin bundle environment that can account for the altered physical properties. Finally, proof

  20. Comparison of physically based constitutive models characterizing armor steel over wide temperature and strain rate ranges

    International Nuclear Information System (INIS)

    Xu, Zejian; Huang, Fenglei

    2012-01-01

    Both descriptive and predictive capabilities of five physically based constitutive models (PB, NNL, ZA, VA, and RK) are investigated and compared systematically, in characterizing plastic behavior of the 603 steel at temperatures ranging from 288 to 873 K, and strain rates ranging from 0.001 to 4500 s −1 . Determination of the constitutive parameters is introduced in detail for each model. Validities of the established models are checked by strain rate jump tests performed under different loading conditions. The results show that the RK and NNL models have better performance in the description of material behavior, especially the work-hardening effect, while the PB and VA models predict better. The inconsistency that is observed between the capabilities of description and prediction of the models indicates the existence of the minimum number of required fitting data, reflecting the degree of a model's requirement for basic data in parameter calibration. It is also found that the description capability of a model is dependent to a large extent on both its form and the number of its constitutive parameters, while the precision of prediction relies largely on the performance of description. In the selection of constitutive models, the experimental data and the constitutive models should be considered synthetically to obtain a better efficiency in material behavior characterization

  1. Comparison of physically based constitutive models characterizing armor steel over wide temperature and strain rate ranges

    Science.gov (United States)

    Xu, Zejian; Huang, Fenglei

    2012-01-01

    Both descriptive and predictive capabilities of five physically based constitutive models (PB, NNL, ZA, VA, and RK) are investigated and compared systematically, in characterizing plastic behavior of the 603 steel at temperatures ranging from 288 to 873 K, and strain rates ranging from 0.001 to 4500 s-1. Determination of the constitutive parameters is introduced in detail for each model. Validities of the established models are checked by strain rate jump tests performed under different loading conditions. The results show that the RK and NNL models have better performance in the description of material behavior, especially the work-hardening effect, while the PB and VA models predict better. The inconsistency that is observed between the capabilities of description and prediction of the models indicates the existence of the minimum number of required fitting data, reflecting the degree of a model's requirement for basic data in parameter calibration. It is also found that the description capability of a model is dependent to a large extent on both its form and the number of its constitutive parameters, while the precision of prediction relies largely on the performance of description. In the selection of constitutive models, the experimental data and the constitutive models should be considered synthetically to obtain a better efficiency in material behavior characterization.

  2. Do it yourself: optical spectrometer for physics undergraduate instruction in nanomaterial characterization

    International Nuclear Information System (INIS)

    Nuryantini, Ade Yeti; Mahen, Ea Cahya Septia; Sawitri, Asti; Nuryadin, Bebeh Wahid

    2017-01-01

    In this paper, we report on a homemade optical spectrometer using diffraction grating and image processing techniques. This device was designed to produce spectral images that could then be processed by measuring signal strength (pixel intensity) to obtain the light source, transmittance, and absorbance spectra of the liquid sample. The homemade optical spectrometer consisted of: (i) a white LED as a light source, (ii) a cuvette or sample holder, (iii) a slit, (iv) a diffraction grating, and (v) a CMOS camera (webcam). In this study, various concentrations of a carbon nanoparticle (CNP) colloid were used in the particle size sample test. Additionally, a commercial optical spectrometer and tunneling electron microscope (TEM) were used to characterize the optical properties and morphology of the CNPs, respectively. The data obtained using the homemade optical spectrometer, commercial optical spectrometer, and TEM showed similar results and trends. Lastly, the calculation and measurement of CNP size were performed using the effective mass approximation (EMA) and TEM. These data showed that the average nanoparticle sizes were approximately 2.4 nm and 2.5 ± 0.3 nm, respectively. This research provides new insights into the development of a portable, simple, and low-cost optical spectrometer that can be used in nanomaterial characterization for physics undergraduate instruction. (paper)

  3. Feasibility and reliability of physical fitness tests in older adults with intellectual disability : A pilot study

    NARCIS (Netherlands)

    Hilgenkamp, Thessa I. M.; van Wijck, Ruud; Evenhuis, Heleen M.

    Background Physical fitness is relevant for wellbeing and health, but knowledge on the feasibility and reliability of instruments to measure physical fitness for older adults with intellectual disability is lacking. Methods Feasibility and test-retest reliability of a physical fitness test battery

  4. The analysis of modern approaches to physical fitness testing of military personnel

    Directory of Open Access Journals (Sweden)

    Glazunov Sergej Ivanovich

    2011-11-01

    Full Text Available The aim of research is to determine modern approaches to the physical fitness testing of service personnel. In the army with modern military experience, marked by a tendency to view the content of tests to determine the level of physical fitness of military personnel. Observed differentiation of unified systems tests to determine the general physical and military training military application. Summary of tests determined the nature of loads and motions of the structure inherent in the military during combat operations.

  5. Characterization by spectroscopic Ellipsometry, the physical properties of silver nanoparticles.

    Science.gov (United States)

    Coanga, Jean-Maurice

    2013-04-01

    Physicists are able to change their minds through their experiments. I think it is time to go kick the curse and go further in research if we want a human future. I work in the Nano-Optics and Plasmonics research. I defined with ellipsomètrie the structure of new type of Nano particles of silver. It's same be act quickly to replace the old dirty leaded electronic-connexion chip and by the other hand to find a new way for the heath care of cancer disease by nanoparticles the next killers of bad cells. Silver nanoparticle layers are obtained by Spark Plasma Sintering are investigated as an alternative to lead alloy based material for solder joint in power mechatronics modules. These layers are characterized by mean of conventional techniques that is the dilatometry technique, the resistivity measurement through the van der Pauw method, and the flash laser technique. Furthermore, the nanoparticles of silver layer are deeply studied by UV-Visible spectroscopic ellipsometry. Spectroscopic angles parameters are determined in function of temperature and dielectric constants are deduced and analyzed through an optical model which takes into account a Drude and a Lorentz component within the Bruggeman effective medium approximation (EMA). The relaxation times and the electrical conductivity are plot in function of temperature. The obtained electrical conductivity give significant result in good agreement to those reported by four points electrical measurement method.

  6. Physical and chemical characterization of synthetic calcined sludge

    International Nuclear Information System (INIS)

    Slates, R.V.; Mosley, W.C. Jr.; Tiffany, B.; Stone, J.A.

    1982-03-01

    Calcined synthetic sludge was chemically characterized in support of engineering studies to design a processing plant to solidify highly radioactive waste at the Savannah River Plant. An analytical technique is described which provides quantitative data by mass spectrometric analysis of gases evolved during thermogravimetric analysis without measurements of gas flow rates or mass spectrometer sensitivities. Scanning electron microprobe analysis, Mossbauer spectroscopy, and several other common analytical methods were also used. Calcined sludge consists primarily of amorphous particles of hydrous oxides with iron, manganese, nickel, and calcium distributed fairly uniformly throughout the powder. Iron, manganese, nickel, and calcium exist in forms that are highly insoluble in water, but aluminum, sulfate, nitrate, and sodium exhibit relative water solubilities that increase in the given order from 60% to 94%. Evolved gas analysis in a helium atmosphere showed that calcined sludge is completely dehydrated by heating to 400 0 C, carbon dioxide is evolved between 100 to 700 0 C with maximum evolution at 500 0 C, and oxygen is evolved between 400 and 1000 0 C. Evolved gas analyses are also reported for uncalcined sludge. A spinel-type oxide similar to NiFe 2 O 4 was detected by x-ray diffraction analysis at very low-level in calcined sludge

  7. PHYSICS

    CERN Multimedia

    P. Sphicas

    There have been three physics meetings since the last CMS week: “physics days” on March 27-29, the Physics/ Trigger week on April 23-27 and the most recent physics days on May 22-24. The main purpose of the March physics days was to finalize the list of “2007 analyses”, i.e. the few topics that the physics groups will concentrate on for the rest of this calendar year. The idea is to carry out a full physics exercise, with CMSSW, for select physics channels which test key features of the physics objects, or represent potential “day 1” physics topics that need to be addressed in advance. The list of these analyses was indeed completed and presented in the plenary meetings. As always, a significant amount of time was also spent in reviewing the status of the physics objects (reconstruction) as well as their usage in the High-Level Trigger (HLT). The major event of the past three months was the first “Physics/Trigger week” in Apri...

  8. The Physical Activity Scale for Individuals with Physical Disabilities : test-retest reliability and comparison with an accelerometer

    NARCIS (Netherlands)

    van der Ploeg, Hidde P; Streppel, Kitty R M; van der Beek, Allard J; van der Woude, Luc H V; Vollenbroek-Hutten, Miriam; van Mechelen, Willem; van der Woude, Lucas

    BACKGROUND: The objective was to determine the test-retest reliability and criterion validity of the Physical Activity Scale for Individuals with Physical Disabilities (PASIPD). METHODS: Forty-five non-wheelchair dependent subjects were recruited from three Dutch rehabilitation centers. Subjects'

  9. An Empirical Analysis of the Physical Aptitude Exam as a Predictor of Performance on the Physical Readiness Test

    National Research Council Canada - National Science Library

    Patrick, Robert

    2000-01-01

    ... shuttle run, a standing longiump, and a kneeling basketball throw. The Physical Readiness Test, administered semi-annually to all naval personnel including midshipmen, consists of modified situps, pushups, and a 1.5-mile run...

  10. Temperature buffer test. Hydro-mechanical and chemical/ mineralogical characterizations

    Energy Technology Data Exchange (ETDEWEB)

    Aakesson, Mattias; Olsson, Siv; Dueck, Ann; Nilsson, Ulf; Karnland, Ola [Clay Technology AB, Lund (Sweden); Kiviranta, Leena; Kumpulainen, Sirpa [BandTech Oy, Helsinki (Finland); Linden, Johan [Aabo Akademi, Aabo (Finland)

    2012-01-15

    The Temperature Buffer Test (TBT) is a joint project between SKB/ANDRA and supported by ENRESA (modeling) and DBE (instrumentation), which aims at improving the understanding and to model the thermo-hydro-mechanical behavior of buffers made of swelling clay submitted to high temperatures (over 100 deg C) during the water saturation process. The test has been carried out in a KBS-3 deposition hole at Aspo HRL. It was installed during the spring of 2003. Two steel heaters (3 m long, 0.6 m diameter) and two buffer arrangements have been investigated: the lower heater was surrounded by rings of compacted Wyoming bentonite only, whereas the upper heater was surrounded by a composite barrier, with a sand shield between the heater and the bentonite. The test was dismantled and sampled during the winter of 2009/2010. This report presents the hydro-mechanical and chemical/mineralogical characterization program which was launched subsequent to the dismantling operation. The main goal has been to investigate if any significant differences could be observed between material from the field experiment and the reference material. The field samples were mainly taken from Ring 4 (located at the mid-section around the lower heater), in which the temperature in the innermost part reached 155 deg C. The following hydro-mechanical properties have been determined for the material (test technique within brackets): hydraulic conductivity (swelling pressure device), swelling pressure (swelling pressure device), unconfined compression strength (mechanical press), shear strength (triaxial cell) and retention properties (jar method). The following chemical/mineralogical properties (methods within brackets) were determined: anion analysis of water leachates (IC), chemical composition (ICP/AES+MS, EGA), cation exchange capacity (CEC, Cu-trien method) and exchangeable cations (exchange with NH4, ICPAES), mineralogical composition (XRD and FTIR), element distribution and microstructure (SEM and

  11. Reliability of six physical performance tests in older people with dementia

    NARCIS (Netherlands)

    Blankevoort, C.G.; Heuvelen, M.J.; Scherder, E.J.A.

    2012-01-01

    Background. Physical performance tests are important for assessing the effect of physical activity interventions in older people with dementia, but their psychometric properties have not been systematically established within this specific population. Objective. The purpose of this study was to

  12. Reliability of Six Physical Performance Tests in Older People With Dementia

    NARCIS (Netherlands)

    Blankevoort, Christiaan G.; van Heuvelen, Marieke J. G.; Scherder, Erik J. A.

    Background. Physical performance tests are important for assessing the effect of physical activity interventions in older people with dementia, but their psychometric properties have not been systematically established within this specific population. Objective. The purpose of this study was to

  13. A simple field test for the assessment of physical fitness.

    Science.gov (United States)

    1963-04-01

    An essential factor in air safety is the physical and mental fitness of all personnel directly involved in operations of general, commercial, and military aviation. Standardization and classification of fitness, however, have not been established to ...

  14. Cloning and physical characterization of chromosomal conjugative elements in streptococci

    Energy Technology Data Exchange (ETDEWEB)

    Vijayakumar, M.N.; Priebe, S.D.; Pozzi, G.; Hageman, J.M.; Guild, W.R.

    1986-06-01

    A directed insertion method was used to introduce a nonreplicating vector plasmid into the large conjugative cat-tet element found in the chromosome of Streptococcus pneumoniae BM6001 and derivatives. To direct insertion preferentially to the conjugative element, we transferred it by conjugation to Streptococcus faecalis and then used DNA from this strain as a source of restriction nuclease fragments for ligation to digests of the vector pVA891, which can replicate in Escherichia coli but not in streptococci. This ligation mix was used to transform pneumococcal cells carrying the cat-tet element, with selection for the erythromycin resistance carried by pVA891. Eight such isolates were found, and transformation and conjugation tests showed that in each case the vector had inserted into the conjugative element, as expected. DNA from these pneumococcal strains generated a variety of E. coli plasmids which provide tools for obtaining a detailed restriction map and for defining other structural features of the streptococcal conjugative element.

  15. Synthesis, characterization, and physical properties of 1D nanostructures

    Science.gov (United States)

    Marley, Peter Mchael

    framework is facilitated by the nanometer-sized dimensions of the materials, which leads to accommodation of strain without amorphization. The topotactic approach demonstrated here indicates not just novel intercalation chemistry accessible at nanoscale dimensions but also suggests a facile synthetic route to ternary vanadium oxide bronzes (MxV2O 5) exhibiting intriguing physical properties that range from electronic phase transitions to charge ordering and superconductivity.

  16. A Novel Physical Sensing Principle for Liquid Characterization Using Paper-Based Hygro-Mechanical Systems (PB-HMS).

    Science.gov (United States)

    Perez-Cruz, Angel; Stiharu, Ion; Dominguez-Gonzalez, Aurelio

    2017-07-20

    In recent years paper-based microfluidic systems have emerged as versatile tools for developing sensors in different areas. In this work; we report a novel physical sensing principle for the characterization of liquids using a paper-based hygro-mechanical system (PB-HMS). The PB-HMS is formed by the interaction of liquid droplets and paper-based mini-structures such as cantilever beams. The proposed principle takes advantage of the hygroscopic properties of paper to produce hygro-mechanical motion. The dynamic response of the PB-HMS reveals information about the tested liquid that can be applied to characterize certain properties of liquids. A suggested method to characterize liquids by means of the proposed principle is introduced. The experimental results show the feasibility of such a method. It is expected that the proposed principle may be applied to sense properties of liquids in different applications where both disposability and portability are of extreme importance.

  17. U.S. Army Physical Demands Study: Development of the Occupational Physical Assessment Test for Combat Arms soldiers.

    Science.gov (United States)

    Foulis, Stephen A; Sharp, Marilyn A; Redmond, Jan E; Frykman, Peter N; Warr, Bradley J; Gebhardt, Deborah L; Baker, Todd A; Canino, Maria C; Zambraski, Edward J

    2017-11-01

    The United States Army sought to create a legally defensible, scientifically validated physical pre-employment screening test. The purpose of this study was to identify a single combination of predictor tests that would predict physical performance on all of the criterion measure task simulations relevant to the Combat Arms military occupational specialties. Concurrent validation. Data from 838 (608 males, 230 females) soldiers who completed both the criterion measure task simulations of a military occupational specialty and up to 14 predictor tests were used in the development of the test batteries. Stepwise regressions were used to identify test batteries that significantly predicted performance on the criterion measure task simulations of the military occupational specialties. Three test batteries were developed based on different subsets of the predictor tests: Test Battery 1 consisted of the medicine ball put, squat lift, beep test, standing long jump, and arm ergometer (adjusted R 2 =0.80-0.85, pTest Battery 2 consisted of the medicine ball put, squat lift, beep test, and standing long jump (adjusted R 2 =0.79-0.80, pTest Battery 3 consisted of the standing long jump, 1-minute push-ups, 1-minute sit-ups, 300m sprint, and Illinois agility test (adjusted R 2 =0.55-0.71, pTest Battery 2 was selected as the Army's Occupational Physical Assessment Test. It was highly predictive of performance of the Combat Arms military occupational specialties, required no complex equipment, and covered a range of physical fitness domains. Published by Elsevier Ltd.

  18. A physical-topological characterization of group response to nuclear power

    International Nuclear Information System (INIS)

    Harms, A.A.; McMaster Univ., Hamilton, Ontario

    1980-01-01

    A physical-topological model of societal response to the introduction of a technology such as nuclear power is proposed. The formation is based on a conceptual-geometric construct familiar in physics and mathematics. An interesting feature of the model is that it provides for the intrinsic inclusion of such intra-societal conflict manifestations as opinion reversals, opinion polarizations and apparent inconsistencies. The general applicability of this characterization to other societal conflict domains is suggested. (author)

  19. The Physical Characterization of Liposome Salicylic Acid Using Transmission Electron Microscope

    International Nuclear Information System (INIS)

    Elman Panjaitan

    2008-01-01

    The physical characterization of liposome, formulated from salicylic acid using thin film hydration methods with cholesterol and soybean lecithin, has been done. The formula was characterized by optical microscopes and Transmission Electron Microscope (TEM). The observation result shows that the salicylic acid can be formulated to liposomes. Soybean lecithin combined with cholesterol (600 mg : 20 mg) was the best formula and the liposome was spherical vesicle like with dimension about 70 nm unit 800 nm. (author)

  20. An Innovative Physical Model for Testing Bucket Foundations

    DEFF Research Database (Denmark)

    Foglia, Aligi; Ibsen, Lars Bo; Andersen, Lars Vabbersgaard

    2012-01-01

    Pa), 20 (kPa), and 30 (kPa) respectively. The comparison between the tests conducted at stress level of 0 (kPa), and the tests with stress level increased, shows remarkable differences. The relationship between scaled overturning moment and rotation is well represented by a power law. The exponent...... of the power law is consistent among all tests carried out with stress level increased. Besides, attention is given to the instantaneous centre of rotation distribution. To validate the mode, the tests are compared with a large scale test by means of a scaling moment. The validation of the model is only...

  1. Commissioning experience and beam physics measurements at the SwissFEL Injector test Facility

    CERN Document Server

    Schietinger, T.; Aiba, M.; Arsov, V.; Bettoni, S.; Beutner, B.; Calvi, M.; Craievich, P.; Dehler, M.; Frei, F.; Ganter, R.; Hauri, C. P.; Ischebeck, R.; Ivanisenko, Y.; Janousch, M.; Kaiser, M.; Keil, B.; Löhl, F.; Orlandi, G. L.; Ozkan Loch, C.; Peier, P.; Prat, E.; Raguin, J.-Y.; Reiche, S.; Schilcher, T.; Wiegand, P.; Zimoch, E.; Anicic, D.; Armstrong, D.; Baldinger, M.; Baldinger, R.; Bertrand, A.; Bitterli, K.; Bopp, M.; Brands, H.; Braun, H. H.; Brönnimann, M.; Brunnenkant, I.; Chevtsov, P.; Chrin, J.; Citterio, A.; Csatari Divall, M.; Dach, M.; Dax, A.; Ditter, R.; Divall, E.; Falone, A.; Fitze, H.; Geiselhart, C.; Guetg, M. W.; Hämmerli, F.; Hauff, A.; Heiniger, M.; Higgs, C.; Hugentobler, W.; Hunziker, S.; Janser, G.; Kalantari, B.; Kalt, R.; Kim, Y.; Koprek, W.; Korhonen, T.; Krempaska, R.; Laznovsky, M.; Lehner, S.; Le Pimpec, F.; Lippuner, T.; Lutz, H.; Mair, S.; Marcellini, F.; Marinkovic, G.; Menzel, R.; Milas, N.; Pal, T.; Pollet, P.; Portmann, W.; Rezaeizadeh, A.; Ritt, S.; Rohrer, M.; Schär, M.; Schebacher, L.; Scherrer, St.; Schlott, V.; Schmidt, T.; Schulz, L.; Smit, B.; Stadler, M.; Steffen, Bernd; Stingelin, L.; Sturzenegger, W.; Treyer, D. M.; Trisorio, A.; Tron, W.; Vicario, C.; Zennaro, R.; Zimoch, D.

    2016-10-26

    The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and test bed for the development and realization of SwissFEL, the x-ray Free Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chicane and a diagnostic section including atransverse deflecting rf cavity. It delivered electron bunchesof up to200 pC chargeand up to 250 MeV beam energy at a repetition rate of 10 Hz. The measurements performed at the test facility not only demonstrated the beam parameters required to drive the first stage of a FEL facility, but also led to significant advances in instrumentation technologies, beam characterization methods and the generation, transport and compression of ultralow-emittance beams. We give a comprehensive overview of the commissioning experience of the principal subsystems and the beam physics measureme...

  2. Virtual Physical Therapy Clinician: Development, Validation and Testing

    Science.gov (United States)

    Huhn, Karen

    2011-01-01

    Introduction: Clinical reasoning skills develop through repeated practice in realistic patient scenarios. Time constraints, declining availability of clinical education sites and patient safety are some of the factors that limit physical therapy educators' ability to expose students to realistic patient scenarios. Computerized simulations may be…

  3. An entrepreneurial physics method and its experimental test

    Science.gov (United States)

    Brown, Robert

    2012-02-01

    As faculty in a master's program for entrepreneurial physics and in an applied physics PhD program, I have advised upwards of 40 master and doctoral theses in industrial physics. I have been closely involved with four robust start-up manufacturing companies focused on physics high-technology and I have spent 30 years collaborating with industrial physicists on research and development. Thus I am in a position to reflect on many articles and advice columns centered on entrepreneurship. What about the goals, strategies, resources, skills, and the 10,000 hours needed to be an entrepreneur? What about business plans, partners, financing, patents, networking, salesmanship and regulatory affairs? What about learning new technology, how to solve problems and, in fact, learning innovation itself? At this point, I have my own method to propose to physicists in academia for incorporating entrepreneurship into their research lives. With this method, we do not start with a major invention or discovery, or even with a search for one. The method is based on the training we have, and the teaching we do (even quantum electrodynamics!), as physicists. It is based on the networking we build by 1) providing courses of continuing education for people working in industry and 2) through our undergraduate as well as graduate students who have gone on to work in industry. In fact, if we were to be limited to two words to describe the method, they are ``former students.'' Data from local and international medical imaging manufacturing industry are presented.

  4. Physical and chemical test results of electrostatic safe flooring materials

    Science.gov (United States)

    Gompf, R. H.

    1988-01-01

    This test program was initiated because a need existed at the Kennedy Space Center (KSC) to have this information readily available to the engineer who must make the choice of which electrostatic safe floor to use in a specific application. The information, however, should be of value throughout both the government and private industry in the selection of a floor covering material. Included are the test results of 18 floor covering materials which by test evaluation at KSC are considered electrostatically safe. Tests were done and/or the data compiled in the following areas: electrostatics, flammability, hypergolic compatibility, outgassing, floor type, material thickness, and available colors. Each section contains the test method used to gather the data and the test results.

  5. Physical Test Validation for Job Selection. Chapter 5

    Science.gov (United States)

    2000-09-21

    ACSM . (1991). Guidelines for exercise testing and prescription. (3’ ed.). (Vol. 4). Philadelphia, PA: Lea and Febiger. 4. Altman, D. G., Bland, J. M...Commission (EEOC) guidelines (EEOC, 1978) as they relate to test validation. The sanctioned validation methods are content validity, criterion-related...1994). The Uniform Guidelines recognize three types of validity with respect to selection test development: content validity, criterion-related

  6. Simple test for physical stability of cryogenic tank insulation

    Science.gov (United States)

    Rossello, D.

    1968-01-01

    Qualitative test determines the ability of insulation liners used on liquid hydrogen tanks to withstand stresses produced by the thermal shocks imparted to the insulation during tank filling and drainage. Test specimens are bonded to metal plates with a low thermal expansion coefficient and are immersed in liquid hydrogen.

  7. Smoking versus Nonsmoking and the Army Physical Fitness Test

    Science.gov (United States)

    1990-06-07

    PF p 0 POP I r rr r r 0 ............ . . . . . . . . . . . 910 0 00 rrrow* vmr ;rrwooFrrwr*worrD: 00 4.4.0 "llri 0 C, 00 !2sq-t"",R ’Rot Big 0 pop loop...Shortness of Breath and Physical Fitness.’ Medical Science and SPorts 4 (Fall 1972): 138. Department of Defense, Department of Defense Report on Smoking

  8. Enhanced verification test suite for physics simulation codes

    Energy Technology Data Exchange (ETDEWEB)

    Kamm, James R.; Brock, Jerry S.; Brandon, Scott T.; Cotrell, David L.; Johnson, Bryan; Knupp, Patrick; Rider, William J.; Trucano, Timothy G.; Weirs, V. Gregory

    2008-09-01

    This document discusses problems with which to augment, in quantity and in quality, the existing tri-laboratory suite of verification problems used by Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and Sandia National Laboratories (SNL). The purpose of verification analysis is demonstrate whether the numerical results of the discretization algorithms in physics and engineering simulation codes provide correct solutions of the corresponding continuum equations.

  9. Demonstration of load rating capabilities through physical load testing : Sioux County bridge case study.

    Science.gov (United States)

    2013-08-01

    The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...

  10. Demonstration of load rating capabilities through physical load testing : Johnson County bridge case study.

    Science.gov (United States)

    2013-08-01

    The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...

  11. Demonstration of load rating capabilities through physical load testing : Ida County bridge case study.

    Science.gov (United States)

    2013-08-01

    The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...

  12. Comments on Thermal Physical Properties Testing Methods of Phase Change Materials

    Directory of Open Access Journals (Sweden)

    Jingchao Xie

    2013-01-01

    Full Text Available There is no standard testing method of the thermal physical properties of phase change materials (PCM. This paper has shown advancements in this field. Developments and achievements in thermal physical properties testing methods of PCM were commented, including differential scanning calorimetry, T-history measurement, the water bath method, and differential thermal analysis. Testing principles, advantages and disadvantages, and important points for attention of each method were discussed. A foundation for standardized testing methods for PCM was made.

  13. Mechanical and thermo-physical characterization of the carbon fibre composite NB31

    Science.gov (United States)

    Pintsuk, G.; Compan, J.; Linke, J.; Majerus, P.; Peacock, A.; Pitzer, D.; Rödig, M.

    2007-03-01

    The use of carbon-based materials, i.e. graphite and carbon fibre composites (CFCs), as plasma facing materials in experimental nuclear fusion devices is widely spread. For the strike point area of the ITER divertor, a European candidate material was NB31, a three directional (3D) CFC material consisting of ex-pitch, ex-PAN and needled ex-PAN fibres, which will be replaced in the future by the newly developed material NB41. This composite material is used for the fabrication of divertor components for Wendelstein 7-X. In the frame of an extensive characterization on three different material batches of NB31 called 'pilot', 'serial' and 'additional' productions for W7-X and ITER, thermo-physical measurements and tensile tests were performed. The results were correlated to density and microstructure. The latter varied due to difficulties in the manufacturing process, in particular in the needling process. Therefore the specification of a minimum density and unit cell width (combined thickness of an ex-pitch and ex-PAN layer) is necessary to meet the ITER specifications for tensile strength and for thermal conductivity in the ex-pitch direction.

  14. Physical and Mechanical Characterization of Sugarcane Bagasse Particleboards for Civil Construction

    Directory of Open Access Journals (Sweden)

    Rosane Battistelle

    2016-12-01

    Full Text Available In the worldwide market of particleboard production, the use of alternative raw materials is increasing, due to high demand and lack of traditional raw material, despite efforts of reforestation. In Brazil, the main agricultural commodity is sugarcane due to the copious production of sugar and ethanol. In the state of São Paulo alone approximately 140 million tons of sugarcane bagasse are produced every year, from which around 70% is burned for energy production, not adding value to the residue and generating pollution to the environment; and the other 30% is sold for composting. The objective of this work is to add value to the sugarcane bagasse by using it as a raw material for particleboard production to be employed as flooring in the area of civil construction. To achieve this, the present research characterized the physical and mechanical characteristics of the particleboards with the following alternative raw materials: sugarcane bagasse and leaves of bamboo. Particleboards were produced to reach high density (0.8g/cm3 using the resin (bi-component polyurethane castor oil. Tests for abrasion, roughness and resistance to denting and wear (Janka hardness verified that the addition of leaves of bamboo in the mixtures, contrary to what was expected, did not confer a greater degree of resistance to the particleboards. Lastly, the results showed that sugarcane bagasse is a viable raw material alternative for the production of particleboards, intended to be used as products and flooring.

  15. Fuel Thermo-physical Characterization Project: Evaluation of Models to Calculate Thermal Diffusivity of Layered Composites

    Energy Technology Data Exchange (ETDEWEB)

    Burkes, Douglas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Casella, Amanda J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Gardner, Levi D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Casella, Andrew M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Huber, Tanja K. [Technische Universität München, Munich (Germany); Breitkreutz, Harald [Technische Universität München, Munich (Germany)

    2015-02-11

    The Office of Material Management and Minimization Fuel Thermo-physical Characterization Project at Pacific Northwest National Laboratory (PNNL) is tasked with using PNNL facilities and processes to receive irradiated low enriched uranium-molybdenum fuel plate samples and perform analyses in support of the Office of Material Management and Minimization Reactor Conversion Program. This work is in support of the Fuel Development Pillar that is managed by Idaho National Laboratory. A key portion of the scope associated with this project was to measure the thermal properties of fuel segments harvested from plates that were irradiated in the Advanced Test Reactor. Thermal diffusivity of samples prepared from the fuel segments was measured using laser flash analysis. Two models, one developed by PNNL and the other developed by the Technische Universität München (TUM), were evaluated to extract the thermal diffusivity of the uranium-molybdenum alloy from measurements made on the irradiated, layered composites. The experimental data of the “TC” irradiated fuel segment was evaluated using both models considering a three-layer and five-layer system. Both models are in acceptable agreement with one another and indicate that the zirconium diffusion barrier has a minimal impact on the overall thermal diffusivity of the monolithic U-Mo fuel.

  16. Radiological, physical, and chemical characterization of transuranic wastes stored at the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Apel, M.L.; Becker, G.K.; Ragan, Z.K.; Frasure, J.; Raivo, B.D.; Gale, L.G.; Pace, D.P.

    1994-03-01

    This document provides radiological, physical and chemical characterization data for transuranic radioactive wastes and transuranic radioactive and hazardous (i.e., mixed) wastes stored at the Idaho National Engineering Laboratory and considered for treatment under the Private Sector Participation Initiative Program (PSPI). Waste characterization data are provided in the form of INEL Waste Profile Sheets. These documents provide, for each content code, information on waste identification, waste description, waste storage configuration, physical/chemical waste composition, radionuclide and associated alpha activity waste characterization data, and hazardous constituents present in the waste. Information is provided for 139 waste streams which represent an estimated total volume of 39,380 3 corresponding to a total mass of approximately 19,000,000 kg. In addition, considerable information concerning alpha, beta, gamma, and neutron source term data specific to Rocky Flats Plant generated waste forms stored at the INEL are provided to assist in facility design specification

  17. Radiological, physical, and chemical characterization of transuranic wastes stored at the Idaho National Engineering Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Apel, M.L.; Becker, G.K.; Ragan, Z.K.; Frasure, J.; Raivo, B.D.; Gale, L.G.; Pace, D.P.

    1994-03-01

    This document provides radiological, physical and chemical characterization data for transuranic radioactive wastes and transuranic radioactive and hazardous (i.e., mixed) wastes stored at the Idaho National Engineering Laboratory and considered for treatment under the Private Sector Participation Initiative Program (PSPI). Waste characterization data are provided in the form of INEL Waste Profile Sheets. These documents provide, for each content code, information on waste identification, waste description, waste storage configuration, physical/chemical waste composition, radionuclide and associated alpha activity waste characterization data, and hazardous constituents present in the waste. Information is provided for 139 waste streams which represent an estimated total volume of 39,380{sup 3} corresponding to a total mass of approximately 19,000,000 kg. In addition, considerable information concerning alpha, beta, gamma, and neutron source term data specific to Rocky Flats Plant generated waste forms stored at the INEL are provided to assist in facility design specification.

  18. Nanoparticles for intravascular applications: physicochemical characterization and cytotoxicity testing

    NARCIS (Netherlands)

    Matuszak, J.; Baumgartner, J.; Zaloga, J.; Juenet, M.; Da Silva, A.E.; Franke, D.; Almer, G.; Texier, I.; Faivre, D.; Metselaar, Josbert Maarten; Navarro, F.P.; Chauvierre, C.; Prassl, R.; Dézsi, L.; Urbanics, R.; Alexiou, C.; Mangge, H.; Szebeni, J.; Letourneur, D.; Cicha, I.

    2016-01-01

    Aim: We report the physicochemical analysis of nanosystems intended for cardiovascular applications and their toxicological characterization in static and dynamic cell culture conditions. Methods: Size, polydispersity and ζ-potential were determined in 10 nanoparticle systems including liposomes,

  19. Feasibility test on green energy harvesting from physical exercise devices

    Science.gov (United States)

    Mustafi, Nirendra N.; Mourshed, M.; Masud, M. H.; Hossain, M. S.; Kamal, M. R.

    2017-06-01

    The demand of power is increasing day by day due to the increase of world population as well as the industrialization and modernization. Depletion of the world's fossil fuel reserves and the adverse effects of their uses on the environment insist the researchers to find out some means of efficient and cost effective alternative energy sources from small to large scales. In a gymnasium the human metabolism power is used to drive the physical exercise devices. However there are a number of exercise device which can have the potential to generate electricity during physical exercise. By converting the available mechanical energy from these exercise devices into kinetic energy, electric power can be produced. In this work, energy was harvested from the most commonly used physical exercise devices used in the gymnasium - paddling and chin up. The paddle pulley and the chin up pulley were connected to the couple pulley which in turn coupled to an alternator by a V-belt to produce electrical energy and a rechargeable battery was used to store electrical energy. The power generation from the device depends upon the speed at which the alternator runs and the age limit. The electrical energy output was observed 83.6 watt at 1300 rpm and 62.5 watt at1150 rpm alternator speed for the paddling and chin up respectively recorded for an average adult. The device was designed for a constant 49N load on the alternator for both paddling and chin up operation. By running each of these devices for about 12 hours in a day, any gymnasium can avoid burning of almost 23.67 kg and 31.6 kg of diesel fuel per year for chin up and paddling respectively. Also it can cut off the CO2 emission to the environment which reveals itself a standalone green micro gym.

  20. Test-retest reliability of Eurofit Physical Fitness items for children with visual impairments

    NARCIS (Netherlands)

    Houwen, Suzanne; Visscher, Chris; Hartman, Esther; Lemmink, Koen A. P. M.

    The purpose of this study was to examine the test-retest reliability of physical fitness items from the European Test of Physical Fitness (Eurofit) for children with visual impairments. A sample of 21 children, ages 6-12 years, that were recruited from a special school for children with visual

  1. X-ray based methods for non-destructive testing and material characterization

    International Nuclear Information System (INIS)

    Hanke, Randolf; Fuchs, Theobald; Uhlmann, Norman

    2008-01-01

    The increasing complexity and miniaturization in the field of new materials as well as in micro-production requires in the same way improvements and technical advances in the field of micro-NDT to provide better quality data and more detailed knowledge about the internal structures of micro-components. Therefore, non-destructive methods like radioscopy, ultrasound, optical or thermal imaging increasingly gain in importance with respect to ongoing product and material development in the different phases like material characterization, production control or module reliability testing. Because of the manifold different application fields, i.e., certain physical NDT methods applied to material inspection, characterization or reliability testing, this contribution will focus on the radioscopic-based methods related to their most important applications. Today, in modern industrial quality control, X-ray transmission is used in two different ways: - Two-dimensional radioscopic transmission imaging (projection technique), usually applied to inline inspection tasks in application fields like lightweight material production, electronic component soldering or food production. - Computed tomography (CT) for generation of three-dimensional data, representing spatial information and density distribution of objects. CT application fields are on the one hand the understanding of production process failure or component and module inspection (completeness) and on the other hand the dimensional measuring of hidden geometrical outlines (metrology). This paper demonstrates the methods including technical set-ups (X-ray source and detector), imaging and reconstruction results and the methods for high speed and high-resolution volume data generation and evaluation

  2. Characterizing pedagogical practices of university physics students in informal learning environments

    Science.gov (United States)

    Hinko, Kathleen A.; Madigan, Peter; Miller, Eric; Finkelstein, Noah D.

    2016-06-01

    [This paper is part of the Focused Collection on Preparing and Supporting University Physics Educators.] University educators (UEs) have a long history of teaching physics not only in formal classroom settings but also in informal outreach environments. The pedagogical practices of UEs in informal physics teaching have not been widely studied, and they may provide insight into formal practices and preparation. We investigate the interactions between UEs and children in an afterschool physics program facilitated by university physics students from the University of Colorado Boulder. In this program, physics undergraduates, graduate students, and postdoctoral researchers work with K-8 children on hands-on physics activities on a weekly basis over the course of a semester. We use an activity theoretic framework as a tool to examine situational aspects of individuals' behavior in the complex structure of the afterschool program. Using this framework, we analyze video of UE-child interactions and identify three main pedagogical modalities that UEs display during activities: instruction, consultation, and participation modes. These modes are characterized by certain language, physical location, and objectives that establish differences in UE-child roles and division of labor. Based on this analysis, we discuss implications for promoting pedagogical strategies through purposeful curriculum development and university educator preparation.

  3. New possibilities for testing local realism in high energy physics

    International Nuclear Information System (INIS)

    Li Junli; Qiao Congfeng

    2009-01-01

    The three photons from the dominant ortho-positronium decay and two vector mesons from the η c exclusive decays are found to be in tripartite and high-dimensional entangled states, respectively. These two classes of entangled states possess the Hardy type nonlocality and allow a priori for quantum mechanics vs local realism test via Bell inequalities. The experimental realizations are shown to be feasible, and a concrete scheme to fulfill the test in experiment via two-vector-meson entangled state is proposed.

  4. High School Physical Education Teachers' Attitudes and Use of Fitness Tests

    Science.gov (United States)

    Mercier, Kevin; Phillips, Sharon; Silverman, Stephen

    2016-01-01

    Recommendations for using and implementing fitness tests have been extensively researched and teachers' attitudes toward fitness tests are beginning to be studied. Less understood is how high school teachers use fitness tests and the role their attitudes toward fitness tests affect students' attitudes toward physical activity. The purpose of this…

  5. Digital Platform for Wafer-Level MEMS Testing and Characterization Using Electrical Response

    Directory of Open Access Journals (Sweden)

    Nuno Brito

    2016-09-01

    Full Text Available The uniqueness of microelectromechanical system (MEMS devices, with their multiphysics characteristics, presents some limitations to the borrowed test methods from traditional integrated circuits (IC manufacturing. Although some improvements have been performed, this specific area still lags behind when compared to the design and manufacturing competencies developed over the last decades by the IC industry. A complete digital solution for fast testing and characterization of inertial sensors with built-in actuation mechanisms is presented in this paper, with a fast, full-wafer test as a leading ambition. The full electrical approach and flexibility of modern hardware design technologies allow a fast adaptation for other physical domains with minimum effort. The digital system encloses a processor and the tailored signal acquisition, processing, control, and actuation hardware control modules, capable of the structure position and response analysis when subjected to controlled actuation signals in real time. The hardware performance, together with the simplicity of the sequential programming on a processor, results in a flexible and powerful tool to evaluate the newest and fastest control algorithms. The system enables measurement of resonant frequency (Fr, quality factor (Q, and pull-in voltage (Vpi within 1.5 s with repeatability better than 5 ppt (parts per thousand. A full-wafer with 420 devices under test (DUTs has been evaluated detecting the faulty devices and providing important design specification feedback to the designers.

  6. Digital Platform for Wafer-Level MEMS Testing and Characterization Using Electrical Response

    Science.gov (United States)

    Brito, Nuno; Ferreira, Carlos; Alves, Filipe; Cabral, Jorge; Gaspar, João; Monteiro, João; Rocha, Luís

    2016-01-01

    The uniqueness of microelectromechanical system (MEMS) devices, with their multiphysics characteristics, presents some limitations to the borrowed test methods from traditional integrated circuits (IC) manufacturing. Although some improvements have been performed, this specific area still lags behind when compared to the design and manufacturing competencies developed over the last decades by the IC industry. A complete digital solution for fast testing and characterization of inertial sensors with built-in actuation mechanisms is presented in this paper, with a fast, full-wafer test as a leading ambition. The full electrical approach and flexibility of modern hardware design technologies allow a fast adaptation for other physical domains with minimum effort. The digital system encloses a processor and the tailored signal acquisition, processing, control, and actuation hardware control modules, capable of the structure position and response analysis when subjected to controlled actuation signals in real time. The hardware performance, together with the simplicity of the sequential programming on a processor, results in a flexible and powerful tool to evaluate the newest and fastest control algorithms. The system enables measurement of resonant frequency (Fr), quality factor (Q), and pull-in voltage (Vpi) within 1.5 s with repeatability better than 5 ppt (parts per thousand). A full-wafer with 420 devices under test (DUTs) has been evaluated detecting the faulty devices and providing important design specification feedback to the designers. PMID:27657087

  7. Characterization test of the optimized H type grid spring under the in-grid boundary condition

    International Nuclear Information System (INIS)

    Yoon, Kyung Ho; Kim, Hyung Tae; Lee, Kang Hee; Kang, Heung Seok

    2004-01-01

    This paper is dealing with the simplified method for the characterization test. In reality, the spring should be tested with the test specimen of spacer grid assembly itself (assembly-based test). But the available space for loading is very small due to the dimples and the spring of the adjacent straps, much care should be necessary in conducting the assembly-based test. Test results are compared with the previous test results for checking the usability of the assembly-based test

  8. Warped extra dimensions. Flavor, precision tests and Higgs physics

    Energy Technology Data Exchange (ETDEWEB)

    Goertz, Florian

    2011-07-01

    In this thesis, the phenomenology of the Randall-Sundrum setup is investigated. In this context models with and without an enlarged SU(2){sub L} x SU(2){sub R} x U(1){sub X} x P{sub LR} gauge symmetry, which removes corrections to the T parameter and to the Zb{sub L}b{sub L} coupling, are compared with each other. The Kaluza-Klein decomposition is formulated within the mass basis, which allows for a clear understanding of various model-specific features. A complete discussion of tree-level flavor-changing effects is presented. Exact expressions for five dimensional propagators are derived, including Yukawa interactions that mediate flavor-off-diagonal transitions. The symmetry that reduces the corrections to the left-handed Zbb coupling is analyzed in detail. In the literature, Randall-Sundrum models have been used to address the measured anomaly in the tt forward-backward asymmetry. However, it is shown that this is not possible within a natural approach to flavor. The rare decays t{yields}cZ and t{yields}ch are investigated, where in particular the latter could be observed at the LHC. A calculation of {gamma}{sup B}{sub s12} in the presence of new physics is presented. It is shown that the Randall-Sundrum setup allows for an improved agreement with measurements of A{sup s}{sub SL}, S{sub {psi}}{sub {phi}}, and {delta}{gamma}{sub s}. For the first time, a complete one-loop calculation of all relevant Higgs-boson production and decay channels in the custodial Randall-Sundrum setup is performed, revealing a sensitivity to large new-physics scales at the LHC.

  9. Warped extra dimensions. Flavor, precision tests and Higgs physics

    International Nuclear Information System (INIS)

    Goertz, Florian

    2011-01-01

    In this thesis, the phenomenology of the Randall-Sundrum setup is investigated. In this context models with and without an enlarged SU(2) L x SU(2) R x U(1) X x P LR gauge symmetry, which removes corrections to the T parameter and to the Zb L b L coupling, are compared with each other. The Kaluza-Klein decomposition is formulated within the mass basis, which allows for a clear understanding of various model-specific features. A complete discussion of tree-level flavor-changing effects is presented. Exact expressions for five dimensional propagators are derived, including Yukawa interactions that mediate flavor-off-diagonal transitions. The symmetry that reduces the corrections to the left-handed Zbb coupling is analyzed in detail. In the literature, Randall-Sundrum models have been used to address the measured anomaly in the tt forward-backward asymmetry. However, it is shown that this is not possible within a natural approach to flavor. The rare decays t→cZ and t→ch are investigated, where in particular the latter could be observed at the LHC. A calculation of Γ B s 12 in the presence of new physics is presented. It is shown that the Randall-Sundrum setup allows for an improved agreement with measurements of A s SL , S ψφ , and ΔΓ s . For the first time, a complete one-loop calculation of all relevant Higgs-boson production and decay channels in the custodial Randall-Sundrum setup is performed, revealing a sensitivity to large new-physics scales at the LHC.

  10. In Situ Vitrification Engineering-Scale Test ES-INEL-4 Product Characterization Test Plan

    International Nuclear Information System (INIS)

    Weidner, J.R.; Stoots, P.R.

    1990-06-01

    In 1987, the Buried Waste Program (BWP) was established within EG ampersand G Idaho, Inc., the prime contractor at INEL. Following the Environmental Restoration guidelines of the Buried Waste Program, the In Situ Vitrification Program is participating in a Remedial Investigation/Feasibility Study (RI/FS) for permanent disposal of INEL waste, in compliance with the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). This study was requested and is being funded by the Office of Technology Development of the Idaho Operations Office of DOE (DOE-ID). As part of the RI/FS, an in situ vitrification (ISV) scoping study on the treatability of mixed low-level and mixed transuranic-contaminated waste is being performed to determine the applicability of ISV to remediation of waste at SDA. In examination of the ISV process for applicability to SDA waste, this In Situ Vitrification Engineering-Scale Test ES-INEL-4 Product Characterization Test Plan identifies the following: sampling and analysis strategy; sampling procedures; methods to conduct analyses; equipment; and procedures to ensure data quality. 8 refs., 2 tabs

  11. Plasma Plume Characterization of the HERMeS During a 1722-hr Wear Test Campaign

    Science.gov (United States)

    Huang, Wensheng; Williams, George J.; Peterson, Peter Y.; Kamhawi, Hani; Gilland, James H.; Herman, Daniel A.

    2017-01-01

    A 1722-hr wear test campaign of NASA's 12.5-kW Hall Effect Rocket with Magnetic Shielding was completed. This wear test campaign, completed in 2016, was divided into four segments including an electrical configuration characterization test, two short duration tests, and one long wear test. During the electrical configuration characterization test, the plasma plume was examined to provide data to support the down select of the electrical configuration for further testing. During the long wear tests, the plasma plume was periodically examined for indications of changes in thruster behavior. Examination of the plasma plume data from the electrical configuration characterization test revealed a correlation between the plume properties and the presence of a conduction path through the front poles. Examination of the long wear test plasma plume data revealed that the plume characteristics remained unchanged during testing to within the measurement uncertainty.

  12. A test to evaluate the physical impact on technical performance in soccer

    DEFF Research Database (Denmark)

    Rostgaard, Thomas; Iaia, F. Marcello; Simonsen, Dennis S.

    2008-01-01

    The aim of the study was to develop and examine a test for evaluation of the physical and technical capacity of soccer players. Fourteen youth elite (YE) and seven sub-elite (SE) players performed a physical and technical test (PT-test) consisting of 10 long kicks interspersed with intense...... intermittent exercise. In addition, a control test (CON-test) without intense exercise was performed. In both cases, the test result was evaluated by the precision of the 10 kicks. The players also performed the Yo-Yo intermittent recovery test level 2 (Yo-Yo IR2). For the SE-players, blood samples were...... obtained and heart rate was measured before, during, and after the PT-test. A muscle biopsy was collected before and after the PT-test. Coefficient of variation for the PT- and CON-test was 11.7% and 16.0%, respectively. The YE-players performed better (P test (16...

  13. Ultrasonic and advanced methods for nondestructive testing and material characterization

    National Research Council Canada - National Science Library

    Chen, C. H

    2007-01-01

    ... and physics among others. There are at least two dozen NDT methods in use. In fact any sensor that can examine the inside of material nondestructively is useful for NDT. However the ultrasonic methods are still most popular because of its capability, flexibility, and relative cost effectiveness. For this reason this book places a heavy emphasis...

  14. Plutonium recycle test reactor characterization activities and results

    Energy Technology Data Exchange (ETDEWEB)

    Cornwell, B.C.

    1997-05-01

    Report contains results of PRTR core and associated structures characterization performed in January and February of 1997. Radiation survey data are presented, along with recommendations for stabilization activities before transitioning to a decontamination and decommissioning function. Recommendations are also made about handling the waste generated by the stabilization activities, and actions suggested by the Decontamination and Decommissioning organization.

  15. Physical Characterization of Solid-Liquid Slurries at High Weight Fractions Using Optical and Ultrasonic Methods

    International Nuclear Information System (INIS)

    Burgess, L.W.; Brodsky, A.M.; Panetta P.D.

    2005-01-01

    Remediation of highly radioactive waste is a major technical and programmatic challenge for the DOE. Rapid, on-line physical characterization of highly concentrated slurries is required for the safe and efficient remediation of 90 million gallons of high level radioactive waste (HLW), sodium bearing waste, and mixed waste. The research presented here, describes a collaborative effort between Pacific Northwest National Laboratory (PNNL) and the University of Washington (UW) to directly address the need for rapid on-line characterization of the physical properties of HLW slurries during all phases of the remediation process, from in-tank characterization of sediments to monitoring of the concentration, particle size, and degree of agglomeration and gelation of slurries during transport. Near-surface characterization of the slurry flow in the particle size range from nanometer to micrometer is examined using optical low coherence reflectometry. Volumetric characterization at depths in the slurry flow, up to several centimeters in the particle size range from the micrometer to millimeter, is realized by utilizing ultrasonic backscatter and diffuses fields. One of the strengths, the teaming up of significant talents in both experimental and theoretical optics and in ultrasonics, provides a synergistic approach to integrate these complimentary techniques. One of the benefits of this combined approach is the physical characterization of HLW over a concentration and particle size range that is broader than can be achieved with today's technology. This will avoid a costly increase in waste stream volume due to excess dilution, and will lessen chance of plugging pipes that could shut down expensive processing lines

  16. Chemical Characterization and Reactivity Testing of Fuel-Oxidizer Reaction Product (Test Report)

    Science.gov (United States)

    1996-01-01

    The product of incomplete reaction of monomethylhydrazine (MMH) and nitrogen tetroxide (NTO) propellants, or fuel-oxidizer reaction product (FORP), has been hypothesized as a contributory cause of an anomaly which occurred in the chamber pressure (PC) transducer tube on the Reaction Control Subsystem (RCS) aft thruster 467 on flight STS-51. A small hole was found in the titanium-alloy PC tube at the first bend below the pressure transducer. It was surmised that the hole may have been caused by heat and pressure resulting from ignition of FORP. The NASA Johnson Space Center (JSC) White Sands Test Facility (WSTF) was requested to define the chemical characteristics of FORP, characterize its reactivity, and simulate the events in a controlled environment which may have lead to the Pc-tube failure. Samples of FORP were obtained from the gas-phase reaction of MMH with NTO under laboratory conditions, the pulsed firings of RCS thrusters with modified PC tubes using varied oxidizer or fuel lead times, and the nominal RCS thruster firings at WSTF and Kaiser-Marquardt. Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), accelerating rate calorimetry (ARC), ion chromatography (IC), inductively coupled plasma (ICP) spectrometry, thermogravimetric analysis (TGA) coupled to FTIR (TGA/FTIR), and mechanical impact testing were used to qualitatively and quantitatively characterize the chemical, thermal, and ignition properties of FORP. These studies showed that the composition of FORP is variable but falls within a limited range of compositions that depends on the fuel loxidizer ratio at the time of formation, composition of the post-formation atmosphere (reducing or oxidizing), and reaction or postreaction temperature. A typical composition contains methylhydrazinium nitrate (MMHN), ammonium nitrate (AN), methylammonium nitrate (MAN), and trace amounts of hydrazinium nitrate and 1,1-dimethylhydrazinium nitrate. The thermal decomposition

  17. Characterizing Pedagogical Practices of University Physics Students in Informal Learning Environments

    Science.gov (United States)

    Hinko, Kathleen

    2016-03-01

    University educators (UEs) have a long history of teaching physics not only in formal classroom settings but also in informal outreach environments. The pedagogical practices of UEs in informal physics teaching have not been widely studied, and they may provide insight into formal practices and preparation. We investigate the interactions between UEs and children in an afterschool physics program facilitated by university physics students from the University of Colorado Boulder. In this program, physics undergraduates, graduate students and post-doctoral researchers work with K-8 children on hands-on physics activities on a weekly basis over the course of a semester. We use an Activity Theoretic framework as a tool to examine situational aspects of individuals' behavior in the complex structure of the afterschool program. Using this framework, we analyze video of UE-child interactions and identify three main pedagogical modalities that UEs display during activities: Instruction, Consultation and Participation modes. These modes are characterized by certain language, physical location, and objectives that establish differences in UE-child roles and division of labor. Based on this analysis, we discuss implications for promoting pedagogical strategies through purposeful curriculum development and university educator preparation.

  18. Advanced Gun System (AGS) Dynamic Characterization: Modal Test and Analysis, High-Frequency Analysis

    National Research Council Canada - National Science Library

    Berman, Morris

    1999-01-01

    Dynamic characterization tests were performed on the Advanced Gun System (AGS) vehicle. The tests were designed to provide modeling information for high-frequency shock prediction codes, as well as finite element codes...

  19. Complex confining layers : a physical and geochemical characterization of heterogeneous unconsolidated fluvial deposits using a facies-based approach

    NARCIS (Netherlands)

    Helvoort, Pieter-Jan van

    2003-01-01

    A proper characterization of physical and chemical heterogeneities in the subsoil is an important condition for successful modeling of groundwater flow and solute transport. This study focuses on the physical and chemical characterization of a complex confining layer in the Rhine–Meuse deltaic plain

  20. A Study of the Physical Fitness Test in Relation to Demographics, Academic Achievement, and Students' Physical Fitness Perceptions

    Science.gov (United States)

    Mobilia-Jones, Karen

    2010-01-01

    This study examines the overall results of the Physical Fitness Test (PFT) and the six fitness areas of the PFT, academic achievement, demographics and self perceptions and the potential impact on students' performance on the PFT. While academic expectations are increasing, the adolescent obesity rate is also increasing, producing a decline in the…

  1. Design of Test Parts to Characterize Micro Additive Manufacturing Processes

    DEFF Research Database (Denmark)

    Thompson, Mary Kathryn; Mischkot, Michael

    2015-01-01

    The minimum feature size and obtainable tolerances of additive manufacturing processes are linked to the smallest volumetric elements (voxels) that can be created. This work presents the iterative design of a test part to investigate the resolution of AM processes with voxel sizes at the micro...... scale. Each design iteration reduces the test part size, increases the number of test features, improves functionality, and decreases coupling in the part. The final design is a set of three test parts that are easy to orient and measure, and that provide useful information about micro additive...... manufacturing processes....

  2. Condensed tannins from acacia mangium bark: Characterization by spot tests and FTIR

    Science.gov (United States)

    Bharudin, Muhammad Azizi; Zakaria, Sarani; Chia, Chin Hua

    2013-11-01

    This paper describes the adaptation and evaluation of one chemical tests for tannins characterization in acacia mangium bark. Acid butanol test developed to identify respectively condensed tannins is described. The two traditional tests used for tannin characterization namely ferric test and vanillin test were also performed and their functional also discussed. Condensed tannins were extracted from acacia mangium bark using water medium in presence of three different concentration basic reagent of NaOH(5%,10% and 15%) and were characterized by FT-IR spectrometry.

  3. Characterization samples of Tigris river water treated with nano colloidal silver (physically, chemically, microbiologically)

    International Nuclear Information System (INIS)

    Dumboos, H. I.; Beden, S. J.; Zouari, K.; Chkir, N.; Ahmed, H. A.

    2012-12-01

    Many researches of using nano silver in purification of drinking water from bacteria and its effect on stan dared properties as drinking water were established. Two stages accomplished in these projects. First stage include preparation of colloidal silver with characterization process and prepare water samples through sedimentation, filtration process, PH and turbidity measure then treated with colloidal silver in volume ratio (0.1-Λ) ml/100ml. The second stage represent select the better results from stage one and take samples to determine the standard characterization values with chemical, physical and microbiological taste. Results will be compared with Iraq standard certification. (Author)

  4. Exercise Testing Reveals Everyday Physical Challenges of Bariatric Surgery Candidates.

    Science.gov (United States)

    Creel, David B; Schuh, Leslie M; Newton, Robert L; Stote, Joseph J; Cacucci, Brenda M

    2017-12-01

    Few studies have quantified cardiorespiratory fitness among individuals seeking bariatric surgery. Treadmill testing allows researchers to determine exercise capacity through metabolic equivalents. These findings can assist clinicians in understanding patients' capabilities to carry out various activities of daily living. The purpose of this study was to determine exercise tolerance and the variables associated with fitness, among individuals seeking bariatric surgery. Bariatric surgery candidates completed submaximal treadmill testing and provided ratings of perceived exertion. Each participant also completed questionnaires related to history of exercise, mood, and perceived barriers/benefits of exercise. Over half of participants reported that exercise was "hard to very hard" before reaching 70% of heart rate reserve, and one-third of participants reported that exercise was "moderately hard" at less than 3 metabolic equivalents (light activity). Body mass index and age accounted for the majority of the variance in exercise tolerance, but athletic history, employment status, and perceived health benefits also contributed. Perceived benefit scores were higher than barrier scores. Categories commonly used to describe moderate-intensity exercise (3-6 metabolic equivalents) do not coincide with perceptions of intensity among many bariatric surgery candidates, especially those with a body mass index of 50 or more.

  5. Validity of the German Version of the Continuous-Scale Physical Functional Performance 10 Test

    Directory of Open Access Journals (Sweden)

    Irene Härdi

    2017-01-01

    Full Text Available Background. The Continuous-Scale Physical Functional Performance 10 Test (CS-PFP 10 quantitatively assesses physical functional performance in older adults who have a broad range of physical functional ability. This study assessed the validity and reliability of the CS-PFP 10 German version. Methods. Forward-translations and backtranslations as well as cultural adaptions of the test were conducted. Participants were German-speaking Swiss community-dwelling adults aged 64 and older. Concurrent validity was assessed using Pearson correlation coefficients between CS-PFP 10 and gait velocity, Timed Up and Go Test, hand grip strength, SF-36 physical function domain, and Freiburger Physical Activity Questionnaire. Internal consistency was calculated by Cronbach’s alpha. Results. Backtranslation and cultural adaptions were accepted by the CS-PFP 10 developer. CS-PFP 10 total score and subscores (upper body strength, upper body flexibility, lower body strength, balance and coordination, and endurance correlated significantly with all measures of physical function tested. Internal consistency was high (Cronbach’s alpha 0.95–0.98. Conclusion. The CS-PFP 10 German version is valid and reliable for measuring physical functional performance in German-speaking Swiss community-dwelling older adults. Quantifying physical function is essential for clinical practice and research and provides meaningful insight into physical functional performance of older adults. This trial is registered with ClinicalTrials.gov NCT01539200.

  6. Physical Fitness Characteristics of High vs. Low Performers on an Occupationally Specific Physical Agility Test for Patrol Officers.

    Science.gov (United States)

    Dawes, J Jay; Lindsay, Keston; Bero, Jennifer; Elder, Craig; Kornhauser, Charlie; Holmes, Ryan

    2017-10-01

    Law enforcement agencies frequently use physical ability tests (PATs) as a method of evaluating occupational performance. These tests are designed to replicate essential occupational tasks frequently performed by officers in the field. The purpose of this study was to determine whether significant relationships exist between the selected physical fitness tests and PAT performance and to determine which of these tests best differentiates between high and low PAT performers. Full-time highway patrol officers (n = 495) submitted self-reported anthropometric data (mean age = 39.6 + 7.7 years) along with fitness assessments taken from their organization's yearly fitness tests. All subjects completed a series of field-based fitness tests, as well as an occupationally specific PAT. Results of the study indicated that the selected tests accounted for almost 69% of the total variance on PAT performance. Overall, the 20-m meter multistage fitness test, 1-minute sit-up performance, and vertical jump height best predicted PAT performance. Furthermore, it was revealed that high performers were significantly more fit in all measures of dynamic fitness when compared with lower performers. No significant differences were discovered in static strength between groups. Strength and conditioning specialists should focus on developing aerobic capacity, trunk muscular endurance, and whole-body anaerobic power to improve PAT and occupational performance.

  7. Earth-based construction material field tests characterization in the Alto Douro Wine Region

    Science.gov (United States)

    Cardoso, Rui; Pinto, Jorge; Paiva, Anabela; Lanzinha, João Carlos

    2017-12-01

    The Alto Douro Wine Region, located in the northeast of Portugal, a UNESCO World Heritage Site, presents an abundant vernacular building heritage. This building technology is based on a timber framed structure filled with a composite earth-based material. A lack of scientific studies related to this technology is evident, furthermore, principally in rural areas, this traditional building stock is highly deteriorated and damaged because of the rareness of conservation and strengthening works, which is partly related to the non-engineered character of this technology and to the knowledge loosed on that technique. Those aspects motivated the writing of this paper, whose main purpose is the physical and chemical characterization of the earth-based material applied in the tabique buildings of that region through field tests. Consequently, experimental work was conducted and the results obtained allowed, among others, the proposal of a series of adequate field tests. At our knowledge, this is the first time field tests are undertaken for tabique technology. This information will provide the means to assess the suitability of a given earth-based material with regards to this technology. The knowledge from this study could also be very useful for the development of future normative documents and as a reference for architects and engineers that work with this technology to guide and regulate future conservation, rehabilitation or construction processes helping to preserve this important legacy.

  8. Earth-based construction material field tests characterization in the Alto Douro Wine Region

    Directory of Open Access Journals (Sweden)

    Cardoso Rui

    2017-12-01

    Full Text Available The Alto Douro Wine Region, located in the northeast of Portugal, a UNESCO World Heritage Site, presents an abundant vernacular building heritage. This building technology is based on a timber framed structure filled with a composite earth-based material. A lack of scientific studies related to this technology is evident, furthermore, principally in rural areas, this traditional building stock is highly deteriorated and damaged because of the rareness of conservation and strengthening works, which is partly related to the non-engineered character of this technology and to the knowledge loosed on that technique. Those aspects motivated the writing of this paper, whose main purpose is the physical and chemical characterization of the earth-based material applied in the tabique buildings of that region through field tests. Consequently, experimental work was conducted and the results obtained allowed, among others, the proposal of a series of adequate field tests. At our knowledge, this is the first time field tests are undertaken for tabique technology. This information will provide the means to assess the suitability of a given earth-based material with regards to this technology. The knowledge from this study could also be very useful for the development of future normative documents and as a reference for architects and engineers that work with this technology to guide and regulate future conservation, rehabilitation or construction processes helping to preserve this important legacy.

  9. Study on Assessment of Physical Endurance in Older Persons : Availability of 400-m Walking Performance Test

    OpenAIRE

    芳賀, 脩光; 衣笠, 隆; 仲真, 迅; 十枝内, 厚次; 宮崎, 裕美; 岩下, 太郎; 伊藤, 稔; 渡部, 和彦; 佐藤, 祐造; 大野, 秀樹; Shukoh, HAGA; Takashi, KINUGASA; Hayashi, NAKAMA; Koji, TOSHINAI; Hiromi, MIYAZAKI

    1999-01-01

    Few studies have evaluated physical endurance as measured by a walking performance test. We investigated a 400-m walking test which indirectly assesses physical endurance in older people. In Study I, fifty-three healthy subjects aged 67.8±0.7 years performed and incremental treadmill walking test, and a 400-m walking test. The RPE 11(fairly light)level by the Borg scale was regarded as the exercise intensity during the 400-m walking test. Mean value of pred.VO_2max and VO_2@VT were 25.8ml/kg/...

  10. Detailed Geophysical Fault Characterization in Yucca Flat, Nevada Test Site, Nevada

    Science.gov (United States)

    Asch, Theodore H.; Sweetkind, Donald S.; Burton, Bethany L.; Wallin, Erin L.

    2009-01-01

    Yucca Flat is a topographic and structural basin in the northeastern part of the Nevada Test Site (NTS) in Nye County, Nevada. Between the years 1951 and 1992, 659 underground nuclear tests took place in Yucca Flat; most were conducted in large, vertical excavations that penetrated alluvium and the underlying Cenozoic volcanic rocks. Radioactive and other potential chemical contaminants at the NTS are the subject of a long-term program of investigation and remediation by the U.S. Department of Energy (DOE), National Nuclear Security Administration, Nevada Site Office, under its Environmental Restoration Program. As part of the program, the DOE seeks to assess the extent of contamination and to evaluate the potential risks to humans and the environment from byproducts of weapons testing. To accomplish this objective, the DOE Environmental Restoration Program is constructing and calibrating a ground-water flow model to predict hydrologic flow in Yucca Flat as part of an effort to quantify the subsurface hydrology of the Nevada Test Site. A necessary part of calibrating and evaluating a model of the flow system is an understanding of the location and characteristics of faults that may influence ground-water flow. In addition, knowledge of fault-zone architecture and physical properties is a fundamental component of the containment of the contamination from underground nuclear tests, should such testing ever resume at the Nevada Test Site. The goal of the present investigation is to develop a detailed understanding of the geometry and physical properties of fault zones in Yucca Flat. This study was designed to investigate faults in greater detail and to characterize fault geometry, the presence of fault splays, and the fault-zone width. Integrated geological and geophysical studies have been designed and implemented to work toward this goal. This report describes the geophysical surveys conducted near two drill holes in Yucca Flat, the data analyses performed, and the

  11. Physical and chemical characterization of the (Th, U)O2 mixed oxide fuel

    International Nuclear Information System (INIS)

    Santos, A.M.M. dos; Avelar, M.M.; Palmieri, H.E.L.; Lameiras, F.S.; Ferreira, R.A.N.

    1986-01-01

    The NUCLEBRAS R and D Center (Centro de Desenvolvimento da Tecnologia Nuclear - CDTN) has been performing, together with german institutions (Kernforschungsanlage Julich GmbH - KFA, Krafwerk Union A.G. - KWU and NUKEM GmbH), a program for utilization of thorium in pressurized water reactors. In this paper are presented the physical and chemical characterizations necessary to quality the (Th, U)O 2 fuel and the respective methods. (Author) [pt

  12. Physical Education Teacher Attitudes toward Fitness Tests Scale: Cross-Revalidation and Modification

    Science.gov (United States)

    Keating, Xiaofen D.; Guan, Jianmin; Ferguson, Robert H.; Chen, Li; Bridges, Dwan M.

    2008-01-01

    This study aimed to provide further evidence of validity and reliability for the Physical Education Teacher Attitudes toward Fitness Tests Scale (PETAFTS), which consisted of affective and cognitive domains. There were two subdomains in the affective domain (i.e., enjoyment of implementing fitness tests and enjoyment of using test results) and one…

  13. Preparation, characterization and single cell testing of new ionic conducting polymers for fuel cell applications

    Science.gov (United States)

    Escribano, P. G.; del Río y, C.; Acosta, J. L.

    In this work, heterogeneous sulfonation and both, structural and electrical characterization of a mixture composed on block copolymer ionomers (HSBS and EPDM) and commercial silica, are studied. The incorporation of sulfonic groups was checked by infrared spectroscopy (FTIR-ATR). Microstructure was studied by means of dynamic mechanical analysis (DMA). Also, water uptake and methanol crossover were determined, and the results were compared with those of Nafion ® 117. Electrical behavior was recorded by means of electrochemical impedance spectroscopy (EIS) at different hydration times. Results show that sulfonation of the styrene rings has effectively occurred. Conductivity values are similar to Nafion and they improve with hydration time. Methanol crossover is lower than in Nafion. Finally, a single complete proton exchange membrane fuel cell (PEMFC) as a whole was tested obtaining the polarization and power curves at different temperatures and pressures, and modeling it by an electrical equivalent circuit (EC) in the symmetrical mode (SM) configuration using the EIS technique. This study offers a physical interpretation relating physical parameters to several processes occurring in the system. Power density values are higher than in Nafion.

  14. Physical, mechanical and microscopic characterization of cold bonded fly ash lightweight aggregates

    Directory of Open Access Journals (Sweden)

    Videla, C.

    2002-12-01

    Full Text Available This study presents the results of the different tests carried out on fly ash lightweight aggregates produced with three different kinds of binders: Lime, Portland cement and Pozzolan Portland cement. The elaboration process used for the aggregates consisted in an agglomeration system by agitation under cold bonded hardening conditions. The tests carried out were a physical characterization of the aggregates, the determination of mechanical properties with a crushing test and, finally, the study of the microstructure of the aggregates with scanning electron microscopy (SEM and dispersive energy X ray (EDX. From the point of view of mechanical strength, the results indicate that the best kind of aggregate is the one made with a 5% Pozzolan Portland cement. This result was confirmed by the microstructure analysis, which shows that this kind of aggregate presents the highest hydration speed.

    El estudio presenta los resultados obtenidos de ensayos realizados sobre áridos ligeros de cenizas volantes fabricados con tres tipos de conglomerantes: cal, cemento Portland puro y cemento portland puzolánico. El proceso de fabricación empleado para la elaboración de los áridos consistió en un sistema de aglomeración por agitación bajo condiciones de endurecimiento enfrío. Los ensayos efectuados comprenden la caracterización física de los áridos, la determinación de las propiedades mecánicas por medio de un ensayo de trituración y, finalmente, el estudio de la microestructura de los áridos con técnicas de microscopía de barrido (SEM y energía dispersiva de rayos X (EDX. Desde el punto de vista de resistencia mecánica los resultados indican que el mejor tipo de árido es el fabricado con un 5% de cemento portland puzolánico. Este resultado se confirma con el análisis de la microestructura que demuestra que este tipo de árido presenta la mayor velocidad de hidratación.

  15. Physical Mapping Technologies for the Identification and Characterization of Mutated Genes to Crop Quality

    International Nuclear Information System (INIS)

    2011-09-01

    The improvement of quality traits in food and industrial crops is an important breeding objective for both developed and developing countries in order to add value to the crop and thereby increasing farmers' income. It has been well established that the application of mutagens can be a very important approach for manipulating many crop characteristics including quality. While mutation induction using nuclear techniques such as gamma irradiation is a power tool in generating new genotypes with favourable alleles for improving crop quality in plant breeding, a more thorough understanding of gene expression, gene interactions, and physical location will improve ability to manipulate and control genes, and directly lead to crop improvement. Physical mapping technologies, molecular markers and molecular cytogenetic techniques are tools available with the potential to enhance the ability to tag genes and gene complexes to facilitate the selection of desirable genotypes in breeding programmes, including those based on mutation breeding. This Coordinated Research Project (CRP) on 'Physical Mapping Technologies for the Identification and Characterization of Mutated Genes Contributing to Crop Quality' was conducted under the overall IAEA project objective of 'Identification, Characterization and Transfer of Mutated Genes'. The specific objectives of the CRP were to assist Member States in accelerating crop breeding programmes through the application of physical mapping and complementary genomic approaches, and the characterization and utilization of induced mutants for improvement of crop quality. The IAEA-TECDOC describes the success obtained in the application of molecular cytology, molecular markers, physical mapping and mutation technologies since the inception of the CRP in 2003. The CRP also resulted in two book chapters, 35 peer reviewed papers, 25 conference proceedings, one PhD thesis, and 22 published abstracts. In addition, thirteen sequences were submitted to the

  16. Characterization of Rubbers from Spherical Punch - Plate Indentation Tests

    Directory of Open Access Journals (Sweden)

    Florina Carmen Ciornei

    2016-12-01

    Full Text Available Rubber plates with different compositions and hardness were tested by continuous indentation, using a spherical punch and hysteretic phenomenon was evidenced. The experimental data interpolation with polynomial functions is accurate and permits estimation of the lost work during loading cycles. The interpolation by power law functions is more convenient by using less parameters and having a form accepted in literature. From the rubbers tested, two were considered to present good damping properties.

  17. Physical-biopolymer characterization of polyhydroxybutyrate-co-hydroxyvalerate (PHBV) blended with natural rubber latex

    Energy Technology Data Exchange (ETDEWEB)

    Kuntanoo, K., E-mail: thip-kk@hotmail.com [Graduate School of Khon Kaen University, Khon Kaen, 40002 Thailand (Thailand); Promkotra, S., E-mail: sarunya@kku.ac.th [Department of Geotechnology, Faculty of Technology, Khon Kaen University, Khon Kaen 40002 Thailand (Thailand); Kaewkannetra, P., E-mail: paknar@kku.ac.th [Department of Biotechnology, Faculty of Technology, Khon Kaen University, Khon Kaen 40002 Thailand (Thailand)

    2015-03-30

    A biopolymer of polyhydroxybutyrate-co-hydroxyvalerate (PHBV) is blended with bio-based materials, natural rubber latex, to improve their microstructures. The various ratios between PHBV and natural rubber latex are examined to develop their mechanical properties. In general, physical properties of PHBV are hard, brittle and low flexible while natural rubber (NR) is presented itself as high elastic materials. Concentrations of the PHBV solution are constituted at 1%, 2% and 3% (w/v). The mixtures of their PHBV solutions to natural rubber latex are produced the blended films in three different ratios of 4:6, 5:5 and 6:4, respectively. They are characterized by appearance analyses which are the scanning electron microscope (SEM), universal testing machine (UTM) and differential scanning calorimetry (DSC). The SEM photomicrographs of the blended films and the controlled PHBV can provide the void distribution in the range of 12-14% and 19-21%, respectively. For mechanical properties of the blended films, the various elastic moduli of 1%, 2% and 3% (w/v) PHBV are the average of 773, 956 and 1,007 kPa, respectively. The tensile strengths of the blends increase with the increased concentrations of PHBV, similarly trend to the elastic modulus. The crystallization and melting behavior of unmixed PHBV and the blends are determined by DSC. Melting transition temperatures (T{sub m}) of the unmixed PHBV are stated two melting peak at 154°C and 173°C. Besides, the melting peaks of the blends alter in the range of 152-156°C and 168-171°C, respectively. According to morphology of the blends, the void distribution decreases twice compared to the unmixed PHBV. The results of mechanical properties and thermal analysis indicate that the blended PHBV can be developed their properties by more resilient and wide range of temperature than usual.

  18. Physical-biopolymer characterization of polyhydroxybutyrate-co-hydroxyvalerate (PHBV) blended with natural rubber latex

    Science.gov (United States)

    Kuntanoo, K.; Promkotra, S.; Kaewkannetra, P.

    2015-03-01

    A biopolymer of polyhydroxybutyrate-co-hydroxyvalerate (PHBV) is blended with bio-based materials, natural rubber latex, to improve their microstructures. The various ratios between PHBV and natural rubber latex are examined to develop their mechanical properties. In general, physical properties of PHBV are hard, brittle and low flexible while natural rubber (NR) is presented itself as high elastic materials. Concentrations of the PHBV solution are constituted at 1%, 2% and 3% (w/v). The mixtures of their PHBV solutions to natural rubber latex are produced the blended films in three different ratios of 4:6, 5:5 and 6:4, respectively. They are characterized by appearance analyses which are the scanning electron microscope (SEM), universal testing machine (UTM) and differential scanning calorimetry (DSC). The SEM photomicrographs of the blended films and the controlled PHBV can provide the void distribution in the range of 12-14% and 19-21%, respectively. For mechanical properties of the blended films, the various elastic moduli of 1%, 2% and 3% (w/v) PHBV are the average of 773, 956 and 1,007 kPa, respectively. The tensile strengths of the blends increase with the increased concentrations of PHBV, similarly trend to the elastic modulus. The crystallization and melting behavior of unmixed PHBV and the blends are determined by DSC. Melting transition temperatures (Tm) of the unmixed PHBV are stated two melting peak at 154°C and 173°C. Besides, the melting peaks of the blends alter in the range of 152-156°C and 168-171°C, respectively. According to morphology of the blends, the void distribution decreases twice compared to the unmixed PHBV. The results of mechanical properties and thermal analysis indicate that the blended PHBV can be developed their properties by more resilient and wide range of temperature than usual.

  19. Association between physiological falls risk and physical performance tests among community-dwelling older adults.

    Science.gov (United States)

    Singh, Devinder K A; Pillai, Sharmila G K; Tan, Sin Thien; Tai, Chu Chiau; Shahar, Suzana

    2015-01-01

    Physical performance and balance declines with aging and may lead to increased risk of falls. Physical performance tests may be useful for initial fall-risk screening test among community-dwelling older adults. Physiological profile assessment (PPA), a composite falls risk assessment tool is reported to have 75% accuracy to screen for physiological falls risk. PPA correlates with Timed Up and Go (TUG) test. However, the association between many other commonly used physical performance tests and PPA is not known. The aim of the present study was to examine the association between physiological falls risk measured using PPA and a battery of physical performance tests. One hundred and forty older adults from a senior citizens club in Kuala Lumpur, Malaysia (94 females, 46 males), aged 60 years and above (65.77±4.61), participated in this cross-sectional study. Participants were screened for falls risk using PPA. A battery of physical performance tests that include ten-step test (TST), short physical performance battery (SPPB), functional reach test (FRT), static balance test (SBT), TUG, dominant hand-grip strength (DHGS), and gait speed test (GST) were also performed. Spearman's rank correlation and binomial logistic regression were performed to examine the significantly associated independent variables (physical performance tests) with falls risk (dependent variable). Approximately 13% older adults were at high risk of falls categorized using PPA. Significant differences (Page, TST, SPPB, FRT, SBT, TUG between high and low falls risk group. A significant (Pphysiological falls risk (Pfalls screening to categorize high and low physiological falls risk among community-dwelling older adults. A more comprehensive assessment of falls risk can be performed thereafter for more specific intervention of underlying impairments.

  20. Identify the Tests to Measure Physical Characteristics and Basic Skills for the Football Players in Iraq

    Directory of Open Access Journals (Sweden)

    Mothna Mohammed

    2016-07-01

    Full Text Available Background: Basic skills specification and physical characteristics are the most significant factors for Football players. Objective: This research aims to determine the most relevant tests to examine the basic skills and physical characteristics for the football coaches in Karbala. Methods: The participants of this study includes 92 Football player (body weight 68±16 kg (mean±SD, height 172.5±17.5 cm, age 21±3 year who were chosen from the 4 clubs in Karbala, Iraq. Methods: To choose the appropriate tests for basic skills and physical characteristics the opinion of the experts was used followed by 2 questionnaires, scored from 1 to 5. The tests were recommended for this study and the questionnaire consisted of seven items.  The researcher adapted the questionnaires from previous studies. Results: The findings of questionnaires revealed that vertical jump and dribbling 25 m, sit down and stand up, Nelson reaction, 30 m sprint, passing with wall and Shuttle test are chosen to test the Physical characteristics in football, whereas, accuracy test for shooting, heading the ball, competitor evasion, receiving ball, zigzag dribbling and passing accuracy are chosen to test basic skills in football. Conclusion: The tests which were chosen in this study can be adopted by coaches as a practical way in Karbala and other regions in Iraq and also in other countries. The experts can use the findings of these tests and compare professional athletes and other football players. Keywords: physical characteristics; anthropometric parameters; Basic skills; football

  1. The Swiss Army physical fitness test battery predicts risk of overuse injuries among recruits.

    Science.gov (United States)

    Wyss, T; Von Vigier, R O; Frey, F; Mäder, U

    2012-10-01

    The aim of this study was to quantify the discriminative power of physical performance tests to recognize conscripts with enhanced risk of acute and overuse injuries in specific, physically demanding occupational specialties of the Swiss Army. The five performance tests investigated represent the Swiss Army Physical Fitness Test Battery. Physical fitness performances were assessed during recruitment procedures prior to military service, and injury occurrences were assessed during 18 weeks of boot camp. Complete fitness and injury data of 459 volunteers from four military occupational specialties were collected. Discriminative power of volunteers' aerobic endurance capacity, trunk muscle fitness, muscle power of upper and lower extremities, and balance for predicting risk of acute injuries and for predicting risk of overuse injuries was calculated using receiver operating characteristic curve analysis. The presented fitness tests had no discriminative power for predicting the risk of acute injuries. However, the trunk muscle fitness test was discriminative in predicting overuse injuries in all four military occupational specialties, progressive endurance run in three, balance test in two, and standing long jump in one. Only the seated shot put had no significant power for predicting overuse injuries in all four study groups. However, for different occupational specialties, different fitness parameters were discriminative to predict overuse injuries. It is possible to conclude that the fitness tests used allow detection of conscripts with enhanced overuse injury risk in physically demanding occupational specialties and therefore provide an indicator to select suitable personnel for physically demanding jobs in a military organization.

  2. Initial Characterization of Colombian High School Physics Teachers' Pedagogical Content Knowledge on Electric Fields

    Science.gov (United States)

    Melo-Niño, Lina Viviana; Cañada, Florentina; Mellado, Vicente

    2017-02-01

    We explore the initial characterization of the pedagogical content knowledge of four, in-service, Colombian pre-university secondary education physics teachers on the concept of electric field. Two of them teach the content in English as a second language. The aim of the study was to obtain an image of the participants' teaching of electric field and the inherent complexities that go with that. The results revealed that factors which involved their personal educational models, such as, how they interpret their school's curriculum, the relationship they see between physics and mathematics, the most effective strategies for teaching physics, and the time they have available to develop the topic played a significant role. The teachers considered it essential to establish new strategies that would motivate the pupils by helping them visualize the electric field.

  3. A physical function test for use in the intensive care unit: validity, responsiveness, and predictive utility of the physical function ICU test (scored).

    Science.gov (United States)

    Denehy, Linda; de Morton, Natalie A; Skinner, Elizabeth H; Edbrooke, Lara; Haines, Kimberley; Warrillow, Stephen; Berney, Sue

    2013-12-01

    Several tests have recently been developed to measure changes in patient strength and functional outcomes in the intensive care unit (ICU). The original Physical Function ICU Test (PFIT) demonstrates reliability and sensitivity. The aims of this study were to further develop the original PFIT, to derive an interval score (the PFIT-s), and to test the clinimetric properties of the PFIT-s. A nested cohort study was conducted. One hundred forty-four and 116 participants performed the PFIT at ICU admission and discharge, respectively. Original test components were modified using principal component analysis. Rasch analysis examined the unidimensionality of the PFIT, and an interval score was derived. Correlations tested validity, and multiple regression analyses investigated predictive ability. Responsiveness was assessed using the effect size index (ESI), and the minimal clinically important difference (MCID) was calculated. The shoulder lift component was removed. Unidimensionality of combined admission and discharge PFIT-s scores was confirmed. The PFIT-s displayed moderate convergent validity with the Timed "Up & Go" Test (r=-.60), the Six-Minute Walk Test (r=.41), and the Medical Research Council (MRC) sum score (rho=.49). The ESI of the PFIT-s was 0.82, and the MCID was 1.5 points (interval scale range=0-10). A higher admission PFIT-s score was predictive of: an MRC score of ≥48, increased likelihood of discharge home, reduced likelihood of discharge to inpatient rehabilitation, and reduced acute care hospital length of stay. Scoring of sit-to-stand assistance required is subjective, and cadence cutpoints used may not be generalizable. The PFIT-s is a safe and inexpensive test of physical function with high clinical utility. It is valid, responsive to change, and predictive of key outcomes. It is recommended that the PFIT-s be adopted to test physical function in the ICU.

  4. Physicists purchase materials testing machine in support of pioneering particle physics experiments

    CERN Multimedia

    Sharpe, Suzanne

    2007-01-01

    "The particle physics group at Liverpool University has purchased an LRXPlus singlecolumn materials testing machine from Lloyd Instruments, which will be used to help characterise the carbon-fibre support frames for detectors used for state-of-the-art particle physics experiments." (1 page)

  5. Value of physical tests in diagnosing cervical radiculopathy : a systematic review

    NARCIS (Netherlands)

    Thoomes, Erik J; van Geest, Sarita; van der Windt, Danielle A; Falla, Deborah; Verhagen, Arianne P; Koes, Bart W; Thoomes-de Graaf, Marloes; Kuijper, Barbara; Scholten-Peeters, Wendy Gm; Vleggeert-Lankamp, Carmen L

    Background context In clinical practice, the diagnosis of cervical radiculopathy is based on information from the patient history, physical examination and diagnostic imaging. Various physical tests may be performed, but their diagnostic accuracy is unknown. Purpose To summarize and update the

  6. Pilot-Testing CATCH Early Childhood: A Preschool-Based Healthy Nutrition and Physical Activity Program

    Science.gov (United States)

    Sharma, Shreela; Chuang, Ru-Jye; Hedberg, Ann Marie

    2011-01-01

    Background: The literature on theoretically-based programs targeting healthy nutrition and physical activity in preschools is scarce. Purpose: To pilot test CATCH Early Childhood (CEC), a preschool-based nutrition and physical activity program among children ages three to five in Head Start. Methods: The study was conducted in two Head Start…

  7. Precision tests of the standard model, the Higgs, and new physics

    Indian Academy of Sciences (India)

    journal of. February 2004 physics pp. 149-161. Precision tests of the standard model, the Higgs, and new physics. GUIDO ALTARELLI. Theory Division, CERN ... the Pascos-Wolfenstein ratio of neutral to charged current deep inelastic cross- .... with the direct limit on СА can be improved with respect to the sM, even in the.

  8. Characterization of axial probes used in eddy current testing

    International Nuclear Information System (INIS)

    Wache, G.; Nourrisson, Ph.; Garet, Th.

    2001-01-01

    Customized reference tubes reduced sensitivity discrepancies able to be observed from one probe to the other, due to the gain setting adjustment required for a pre-definite level in amplitude response of the artificial notch. The use of a reference circuit in place of a reference part, makes characterization of the probe matched to its generator more accurate: - the material dependence is cancelled during the compensation process, - the reference signal can be adjusted more accurately in amplitude and phase response, - the manufacturing cost is reduced compared to the one necessary for machining the reference part, - the amplitude and phase response of the reference circuit can be simply modelled by using the transformer relations, such as one can appreciate the variations of the probe definition parameters and its connexion to the generator, and makes them optimal for use. The method proposed by ALSTOM for the characterization of the condenser and exchanger tubing probes, takes in account the amplitude and phase response of a reference circuit versus frequency, such it can be done by using SURECA tubing provided by ASCOT: it allows to control that the frequency values of the probe required for use are inside the useful bandwidth defined by the - 6 dB attenuation from the maximum amplitude response of the reference circuit versus frequency. Examples coming from measurements done among more than 200 probes, for which faults have been observed and replacements made by the manufacturer, are displayed and commented. (authors)

  9. Moessbauer Characterization of Rust Obtained in an Accelerated Corrosion Test

    International Nuclear Information System (INIS)

    Garcia, K. E.; Morales, A. L.; Arroyave, C. E.; Barrero, C. A.; Cook, D. C.

    2003-01-01

    We have performed drying-humectation cyclical processes (CEBELCOR) on eight A36 low carbon steel coupons in NaCl solutions containing 1x10 -2 M and 1x10 -1 M concentrations. The main purpose of these experiments is to contribute to the understanding of the conditions for akaganeite formation. Additionally, and with the idea to perform a complete characterization of the rust, this work also considers the formation of other iron oxide phases. The corrosion products were characterized by Moessbauer spectroscopy and X-ray diffraction techniques. Gravimetric analysis demonstrates that the coupons presented high corrosion rates. Magnetite/maghemite was common in the rust stuck to the steel surface, whereas akaganeite was present only in traces. In the rust collected from the solutions, i.e., the rust that goes away from the metal surface easily, a magnetite/maghemite was not present and akaganeite showed up in larger quantities. These results support the idea that high concentrations of Cl - ions are required for the akaganeite formation. We concluded that akaganeite is not easily bonded to the rust layer; this may lead to the formation of a less protective rust layer and to higher corrosion rates.

  10. [Precautions of physical performance requirements and test methods during product standard drafting process of medical devices].

    Science.gov (United States)

    Song, Jin-Zi; Wan, Min; Xu, Hui; Yao, Xiu-Jun; Zhang, Bo; Wang, Jin-Hong

    2009-09-01

    The major idea of this article is to discuss standardization and normalization for the product standard of medical devices. Analyze the problem related to the physical performance requirements and test methods during product standard drafting process and make corresponding suggestions.

  11. Dynamic Brazilian Test for Mechanical Characterization of Ceramic Ballistic Protection

    Directory of Open Access Journals (Sweden)

    Martina Scapin

    2017-01-01

    Full Text Available The aim of this work is to identify the tensile strength of alumina (Corbit98, by performing Brazilian tests at different loading rate. In this kind of test, generally used for brittle material in static loading conditions, a cylindrical specimen is diametrically compressed and failure is generated in the middle of the component as a consequence of a positive tensile stress. In this work, this experimental technique was applied also in dynamic loading conditions by using a setup based on the Split Hopkinson Pressure Bar. Due to the properties of the investigated material, among which are high hardness, high compressive strength, and brittle behaviour, some precautions were needed to assure the validity of the tests. Digital Image Correlation techniques were applied for the analysis of high framerate videos.

  12. Characterization of benthic communities and physical habitat in the Stanislaus, Tuolumne, and Merced Rivers, California.

    Science.gov (United States)

    Hall, Lenwood W; Killen, William D; Anderson, Ronald D

    2006-04-01

    The primary goal of this study was to characterize physical habitat and benthic communities (macroinvertebrates) in the Stanislaus, Tuolumne and Merced Rivers in California's San Joaquin Valley in 2003. These rivers have been listed as impaired water bodies (303 (d) list) by the State of California due to the presence of organophosphate (OP) insecticides chlorpyrifos and diazinon, Group A pesticides (i.e., organochlorine pesticides), mercury, or unknown toxicity. Based on 10 instream and riparian physical habitat metrics, total physical habitat scores in the Stanislaus River ranged from 124 to 188 (maximum possible total score is 200). The highest total habitat score was reported at the upstream site. Tuolumne River physical habitat scores ranged from 86 to 167. Various Tuolumne River physical habitat metrics, including total habitat score, increased from downstream to upstream in this river. Merced River physical habitat scores ranged from 121 to 170 with a significant increase in various physical habitat metrics, including total habitat score, reported from downstream to upstream. Channel flow (an instream metric) and bank stability (a riparian metric) were the most important physical habitat metrics influencing the various benthic metrics for all three rivers. Abundance measures of benthic macroinvertebrates (5,100 to 5,400 individuals) were similar among the three rivers in the San Joaquin watershed. Benthic communities in all three rivers were generally dominated by: (1) Baetidae species (mayflies) which are a component of EPT taxa generally considered sensitive to environmental degradation; (2) Chironomidae (midges) which can be either tolerant or sensitive to environmental stressors depending on the species; (3) Ephemerellidae (mayflies) which are considered sensitive to pollution stress; and (4) Naididae (aquatic worms) which are generally considered tolerant to environmental stressors. The presence of 117 taxa in the Stanislaus River, 114 taxa in the

  13. Benchmark physics tests in the metallic-fuelled assembly ZPPR-15

    International Nuclear Information System (INIS)

    McFarlane, H.F.; Brumbach, S.B.; Carpenter, S.G.; Collins, P.J.

    1987-01-01

    In the last two years a shift in emphasis to inherent safety and economic competitiveness has led to a resurgence in US interest in metallic-alloy fuels for LMRs. Argonne National Laboratory initiated an extensive testing program for metallic-fuelled LMR technology that has included benchmark physics as one component. The tests done in the ZPPR-15 Program produced the first physics results in over 20 years for a metal-composition LMR core

  14. Material characterization models and test methods for historic building materials

    DEFF Research Database (Denmark)

    Hansen, Tessa Kvist; Peuhkuri, Ruut Hannele; Møller, Eva B.

    2017-01-01

    Predictions of long term hygrothermal performance can be assessed by dynamic hygrothermal simulations, in which material parameters are crucial input. Material parameters for especially historic materials are often unknown; therefore, there is a need to determine important parameters, and simple...... decisive parameters through simple testing of interrelated parameters that are easier to determine....

  15. Nondestructive mechanical characterization of developing biological tissues using inflation testing.

    Science.gov (United States)

    Oomen, P J A; van Kelle, M A J; Oomens, C W J; Bouten, C V C; Loerakker, S

    2017-10-01

    One of the hallmarks of biological soft tissues is their capacity to grow and remodel in response to changes in their environment. Although it is well-accepted that these processes occur at least partly to maintain a mechanical homeostasis, it remains unclear which mechanical constituent(s) determine(s) mechanical homeostasis. In the current study a nondestructive mechanical test and a two-step inverse analysis method were developed and validated to nondestructively estimate the mechanical properties of biological tissue during tissue culture. Nondestructive mechanical testing was achieved by performing an inflation test on tissues that were cultured inside a bioreactor, while the tissue displacement and thickness were nondestructively measured using ultrasound. The material parameters were estimated by an inverse finite element scheme, which was preceded by an analytical estimation step to rapidly obtain an initial estimate that already approximated the final solution. The efficiency and accuracy of the two-step inverse method was demonstrated on virtual experiments of several material types with known parameters. PDMS samples were used to demonstrate the method's feasibility, where it was shown that the proposed method yielded similar results to tensile testing. Finally, the method was applied to estimate the material properties of tissue-engineered constructs. Via this method, the evolution of mechanical properties during tissue growth and remodeling can now be monitored in a well-controlled system. The outcomes can be used to determine various mechanical constituents and to assess their contribution to mechanical homeostasis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Physical examination tests for the diagnosis of femoroacetabular impingement. A systematic review.

    Science.gov (United States)

    Pacheco-Carrillo, Aitana; Medina-Porqueres, Ivan

    2016-09-01

    Numerous clinical tests have been proposed to diagnose FAI, but little is known about their diagnostic accuracy. To summarize and evaluate research on the accuracy of physical examination tests for diagnosis of FAI. A search of the PubMed, SPORTDiscus and CINAHL databases was performed. Studies were considered eligible if they compared the results of physical examination tests to those of a reference standard. Methodological quality and internal validity assessment was performed by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool. The systematic search strategy revealed 298 potential articles, five of which articles met the inclusion criteria. After assessment using the QUADAS score, four of the five articles were of high quality. Clinical tests included were Impingement sign, IROP test (Internal Rotation Over Pressure), FABER test (Flexion-Abduction-External Rotation), Stinchfield/RSRL (Resisted Straight Leg Raise) test, Scour test, Maximal squat test, and the Anterior Impingement test. IROP test, impingement sign, and FABER test showed the most sensitive values to identify FAI. The diagnostic accuracy of physical examination tests to assess FAI is limited due to its heterogenecity. There is a strong need for sound research of high methodological quality in this area. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Summary of Technical Meeting To Compare US/French Approaches for Physical Protection Test Beds

    Energy Technology Data Exchange (ETDEWEB)

    Mack, Thomas Kimball [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Martinez, Ruben [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Thomas, Gerald [National Nuclear Security Administration (NNSA), Washington, DC (United States); Palut, Jean-Michel [French Alternative and Atomic Energy Commission (CEA), Fontenay Aux Roses (France)

    2016-01-01

    In September 2015, representatives of the US Department of Energy/National Nuclear Security Administration, including test bed professionals from Sandia National Laboratories, and representatives of the French Alternative Energies and Atomic Energy Commission participated in a one-week workshop to share best practices in design, organization, operations, utilization, improvement, and performance testing of physical protection test beds. The intended workshop outcomes were to (1) share methods of improving respective test bed methodologies and programs and (2) prepare recommendations for standards regarding creating and operating testing facilities for nations new to nuclear operations. At the workshop, the French and American subject matter experts compared best practices as developed at their respective test bed sites; discussed access delay test bed considerations; and presented the limitations/ constraints of physical protection test beds.

  18. Physical examination tests for screening and diagnosis of cervicogenic headache: A systematic review.

    Science.gov (United States)

    Rubio-Ochoa, J; Benítez-Martínez, J; Lluch, E; Santacruz-Zaragozá, S; Gómez-Contreras, P; Cook, C E

    2016-02-01

    It has been suggested that differential diagnosis of headaches should consist of a robust subjective examination and a detailed physical examination of the cervical spine. Cervicogenic headache (CGH) is a form of headache that involves referred pain from the neck. To our knowledge, no studies have summarized the reliability and diagnostic accuracy of physical examination tests for CGH. The aim of this study was to summarize the reliability and diagnostic accuracy of physical examination tests used to diagnose CGH. A systematic review following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines was performed in four electronic databases (MEDLINE, Web of Science, Embase and Scopus). Full text reports concerning physical tests for the diagnosis of CGH which reported the clinometric properties for assessment of CGH, were included and screened for methodological quality. Quality Appraisal for Reliability Studies (QAREL) and Quality Assessment of Studies of Diagnostic Accuracy (QUADAS-2) scores were completed to assess article quality. Eight articles were retrieved for quality assessment and data extraction. Studies investigating diagnostic reliability of physical examination tests for CGH scored poorer on methodological quality (higher risk of bias) than those of diagnostic accuracy. There is sufficient evidence showing high levels of reliability and diagnostic accuracy of the selected physical examination tests for the diagnosis of CGH. The cervical flexion-rotation test (CFRT) exhibited both the highest reliability and the strongest diagnostic accuracy for the diagnosis of CGH. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Relationship of physical examination test of shoulder instability to arthroscopic findings in dogs.

    Science.gov (United States)

    Devitt, Chad M; Neely, Marlon R; Vanvechten, Brian J

    2007-10-01

    To determine the diagnostic validity of commonly used physical examination maneuvers for shoulder instability. Retrospective study. Dogs (n=24) referred for shoulder arthroscopy. Results of physical maneuvers and arthroscopic findings were recorded and sensitivity, specificity, positive likelihood ratios (LR+), and negative likelihood ratios (LR-) were calculated for each of 4 physical examination test findings for arthroscopic changes in the medial, lateral, cranial, or caudal compartments of the shoulder joint viewed in dorsal recumbency by lateral and craniomedial portals. Distribution of compartment changes was: medial (17 dogs), caudal (15), cranial (12), and lateral (5). The biceps test had a moderate effect (LR+=9) on post-test probability of cranial compartment changes and a small effect on post-test probability of lateral and caudal compartment changes (LR+=3 and 2.4, respectively). Hyperabduction had a minimal effect and mediolateral instability test had a small effect (LR+=1.64 and 2.68, respectively) on post-test probability of medial compartment changes. Craniocaudal instability test had little to no effect on post-test probability of changes in any compartment. Physical examination tests evaluated were limited in their ability to predict the type of arthroscopic pathology in this study population. Clinicians should understand that a diagnostic test performs inconsistently based on prevalence of a condition in a given patient population. The use of likelihood ratios can assist clinicians in determining the probability of intraarticular changes from a group with a differing prevalence than the patient population presented.

  20. Is the Physical Being Taken out of Physical Education? On the Possible Effects of High-Stakes Testing on an Embattled Profession's Curriculum Goals

    Science.gov (United States)

    Seymour, Clancy; Garrison, Mark

    2015-01-01

    Building on recent discussions regarding how current national standards for physical education promote cognitive outcomes over physical outcomes, the authors explore how a new era in high-stakes testing is also contributing to an emphasis on the cognitive, over the physical. While high-stakes testing has been linked to reducing the amount of…

  1. Design of a Test Bench for Intraocular Lens Optical Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Alba-Bueno, Francisco; Vega, Fidel; Millan, Maria S, E-mail: francisco.alba-bueno@upc.edu, E-mail: fvega@oo.upc.edu, E-mail: millan@oo.upc.edu [Departamento de Optica y Optometria, Universidad Politecnica de Cataluna, C/ Violinista Vellsola 37, 08222 Terrassa (Spain)

    2011-01-01

    The crystalline lens is the responsible for focusing at different distances (accommodation) in the human eye. This organ grows throughout life increasing in size and rigidity. Moreover, due this growth it loses transparency through life, and becomes gradually opacified causing what is known as cataracts. Cataract is the most common cause of visual loss in the world. At present, this visual loss is recoverable by surgery in which the opacified lens is destroyed (phacoemulsification) and replaced by the implantation of an intraocular lens (IOL). If the IOL implanted is mono-focal the patient loses its natural capacity of accommodation, and as a consequence they would depend on an external optic correction to focus at different distances. In order to avoid this dependency, multifocal IOLs designs have been developed. The multi-focality can be achieved by using either, a refractive surface with different radii of curvature (refractive IOLs) or incorporating a diffractive surface (diffractive IOLs). To analyze the optical quality of IOLs it is necessary to test them in an optical bench that agrees with the ISO119679-2 1999 standard (Ophthalmic implants. Intraocular lenses. Part 2. Optical Properties and Test Methods). In addition to analyze the IOLs according to the ISO standard, we have designed an optical bench that allows us to simulate the conditions of a real human eye. To do that, we will use artificial corneas with different amounts of optical aberrations and several illumination sources with different spectral distributions. Moreover, the design of the test bench includes the possibility of testing the IOLs under off-axis conditions as well as in the presence of decentration and/or tilt. Finally, the optical imaging quality of the IOLs is assessed by using common metrics like the Modulation Transfer Function (MTF), the Point Spread Function (PSF) and/or the Strehl ratio (SR), or via registration of the IOL's wavefront with a Hartmann-Shack sensor and its

  2. Soil washing physical separations test procedure - 300-FF-1 operable unit

    International Nuclear Information System (INIS)

    Belden, R.D.

    1993-01-01

    This procedure provides the operations approach, a field sampling plan, and laboratory procedures for a soil washing test to be conducted by Alternative Remedial Technologies, Inc. (ART) in the 300-FF-1 area at the Hanford site. The open-quotes Quality Assurance Project Plan for the Soil Washing Physical Separations Test, 300-FF-1 Operable Unit,close quotes Hanford, Washington, Alternative Remedial Technologies, Inc., February 1994 (QAPP) is provided in a separate document that presents the procedural and organizational guidelines for this test. This document describes specifications, responsibilities, and general procedures to be followed to conduct physical separation soil treatability tests in the North Process Pond of the 300-FF-1 Operable Unit (OU) at the Hanford Site. These procedures are based on the open-quotes 300-FF-1 Physical Separations CERCLA Treatability Test Plan, DOE/RL 92-2l,close quotes (DOE-RL 1993)

  3. Miniaturized Charpy test for reactor pressure vessel embrittlement characterization

    Energy Technology Data Exchange (ETDEWEB)

    Manahan, M.P. Sr. [MPM Research and Consulting, Lemont, PA (United States)

    1999-10-01

    Modifications were made to a conventional Charpy machine to accommodate the miniaturized Charpy V-Notch (MCVN) specimens which were fabricated from an archived reactor pressure vessel (RPV) steel. Over 100 dynamic MCVN tests were performed and compared to the results from conventional Charpy V-Notch (CVN) tests to demonstrate the efficacy of the miniature specimen test. The optimized sidegrooved MCVN specimens exhibit transitional fracture behavior over essentially the same temperature range as the CVN specimens which indicates that the stress fields in the MCVN specimens reasonably simulate those of the CVN specimens and this fact has been observed in finite element calculations. This result demonstrates a significant breakthrough since it is now possible to measure the ductile-brittle transition temperature (DBTT) using miniature specimens with only small correction factors, and for some materials as in the present study, without the need for any correction factor at all. This development simplifies data interpretation and will facilitate future regulatory acceptance. The non-sidegrooved specimens yield energy-temperature data which is significantly shifted downward in temperature (non-conservative) as a result of the loss of constraint which accompanies size reduction.

  4. Measurement of Function Post Hip Fracture: Testing a Comprehensive Measurement Model of Physical Function.

    Science.gov (United States)

    Resnick, Barbara; Gruber-Baldini, Ann L; Hicks, Gregory; Ostir, Glen; Klinedinst, N Jennifer; Orwig, Denise; Magaziner, Jay

    2016-07-01

    Measurement of physical function post hip fracture has been conceptualized using multiple different measures. This study tested a comprehensive measurement model of physical function. This was a descriptive secondary data analysis including 168 men and 171 women post hip fracture. Using structural equation modeling, a measurement model of physical function which included grip strength, activities of daily living, instrumental activities of daily living, and performance was tested for fit at 2 and 12 months post hip fracture, and among male and female participants. Validity of the measurement model of physical function was evaluated based on how well the model explained physical activity, exercise, and social activities post hip fracture. The measurement model of physical function fit the data. The amount of variance the model or individual factors of the model explained varied depending on the activity. Decisions about the ideal way in which to measure physical function should be based on outcomes considered and participants. The measurement model of physical function is a reliable and valid method to comprehensively measure physical function across the hip fracture recovery trajectory. © 2015 Association of Rehabilitation Nurses.

  5. Determinants of physical activity among people with spinal cord injury: a test of social cognitive theory.

    Science.gov (United States)

    Ginis, Kathleen A Martin; Latimer, Amy E; Arbour-Nicitopoulos, Kelly P; Bassett, Rebecca L; Wolfe, Dalton L; Hanna, Steven E

    2011-08-01

    Little theory-based research has focused on understanding and increasing physical activity among people with physical disabilities. Testing a social cognitive theory-based model of determinants is important for identifying variables to target in physical activity-enhancing interventions. The aim of this study is to examine Social Cognitive Theory variables as predictors of physical activity among people living with spinal cord injury. Structural equation modeling was used to test a model of Social Cognitive Theory predictors of physical activity (n=160). The model explained 39% of the variance in physical activity. Self-regulation was the only significant, direct predictor. Self-regulatory efficacy and outcome expectations had indirect effects, mediated by self-regulation. Social Cognitive Theory is useful for predicting physical activity in people with spinal cord injury. Self-regulation is the most potent Social Cognitive Theory predictor of physical activity in people with spinal cord injury. Self-regulation and its determinants should be targeted in physical activity-enhancing interventions.

  6. Characterization of the Scale Model Acoustic Test Overpressure Environment using Computational Fluid Dynamics

    Science.gov (United States)

    Nielsen, Tanner; West, Jeff

    2015-01-01

    The Scale Model Acoustic Test (SMAT) is a 5% scale test of the Space Launch System (SLS), which is currently being designed at Marshall Space Flight Center (MSFC). The purpose of this test is to characterize and understand a variety of acoustic phenomena that occur during the early portions of lift off, one being the overpressure environment that develops shortly after booster ignition. The pressure waves that propagate from the mobile launcher (ML) exhaust hole are defined as the ignition overpressure (IOP), while the portion of the pressure waves that exit the duct or trench are the duct overpressure (DOP). Distinguishing the IOP and DOP in scale model test data has been difficult in past experiences and in early SMAT results, due to the effects of scaling the geometry. The speed of sound of the air and combustion gas constituents is not scaled, and therefore the SMAT pressure waves propagate at approximately the same speed as occurs in full scale. However, the SMAT geometry is twenty times smaller, allowing the pressure waves to move down the exhaust hole, through the trench and duct, and impact the vehicle model much faster than occurs at full scale. The DOP waves impact portions of the vehicle at the same time as the IOP waves, making it difficult to distinguish the different waves and fully understand the data. To better understand the SMAT data, a computational fluid dynamics (CFD) analysis was performed with a fictitious geometry that isolates the IOP and DOP. The upper and lower portions of the domain were segregated to accomplish the isolation in such a way that the flow physics were not significantly altered. The Loci/CHEM CFD software program was used to perform this analysis.

  7. A Comparison of Objective Physical Performance Tests and Future Mortality in the Elderly People.

    Science.gov (United States)

    Veronese, Nicola; Stubbs, Brendon; Fontana, Luigi; Trevisan, Caterina; Bolzetta, Francesco; Rui, Marina De; Sartori, Leonardo; Musacchio, Estella; Zambon, Sabina; Maggi, Stefania; Perissinotto, Egle; Corti, Maria Chiara; Crepaldi, Gaetano; Manzato, Enzo; Sergi, Giuseppe

    2017-03-01

    Physical performance is an important predictor of mortality, but little is known on the comparative prognostic utility of different objective physical performance tests in community-dwelling older adults. We compared the prognostic usefulness of several objective physical performance tests on mortality, adjusting our analyses for potential confounders. Among 3,099 older community-dwelling participants included in the Progetto Veneto Anziani study, 2,096 were followed for a mean of 4.4 years. Physical performance tests measured were Short Physical Performance Battery (SPPB), 4-meter gait speed, chair stands time, leg extension and flexion, handgrip strength, and 6-Minute Walking Test (6MWT), treated as continuous variables and categorized in gender-specific quartiles. The main outcome was mortality assessed with death certificates. Participants who died during the follow-up (n = 327) scored significantly worse in all physical performance tests measured at baseline than those who survived (n = 1,769). Using a Harrell's C-index, the highest C-index was observed for 6MWT in men (C-index = 0.735; 95% confidence interval [CI]: 0.701-0.770, p elderly individuals who are at higher risk of death to improve clinical decision making. © The Author 2016. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Training-test module in the system of pedagogical control of physical fitness in lower grades

    Directory of Open Access Journals (Sweden)

    I.N. Peleshenko

    2014-06-01

    Full Text Available Purpose : to substantiate model characteristics of physical fitness of elementary school students of secondary schools through the introduction of training and test module in the pedagogical control. Material : the study involved 320 boys and 278 girls in grades 1-4 schools in Kharkov number number 57, 112, 166. Results : the level of physical fitness of elementary school students with available motor tests and the results are compared between the experimental data and control classes. Found that the introduction of educational test module in the process of physical education in the experimental classes has enhanced the level of physical fitness. In the experimental classes compared to the control classes, there was an increase of indicators (boys 22.2%, girls 24.6%. Conclusions : the introduction of educational test module in the pedagogical control for primary school pupils, will improve the physical fitness of children in the experimental classes, compared with controls, as well as to determine the averages on basic motor tests that can be used as a model characteristics of physical fitness.

  9. Factors that encourage females to pursue physical science careers: Testing five common hypotheses

    Science.gov (United States)

    Hazari, Zahra; Potvin, Geoff; Lock, Robynne M.; Lung, Florin; Sadler, Philip M.; Sonnert, Gerhard

    2012-03-01

    There are many hypotheses regarding factors that may encourage female students to pursue careers in the physical sciences. Using Propensity Score Matching (PSM) on national data (n=7505) drawn from the Persistence Research in Science and Engineering (PRiSE) project, we test five commonly held beliefs including having a single-sex physics class, having a female physics teacher, having female scientist guest speakers in physics class, discussing the work of women scientists in physics class, and discussing the under-representation of women in physics class. The effect of these experiences is compared for female students who are matched on several factors, including parental education, prior science/math interests, and academic background, thereby controlling for the effect of many confounding variables.

  10. Physical aggression, compromised social support, and 10-year marital outcomes: Testing a relational spillover model.

    Science.gov (United States)

    Sullivan, Kieran T; Pasch, Lauri A; Lawrence, Erika; Bradbury, Thomas N

    2015-12-01

    The purpose of the present study was to test a relational spillover model of physical aggression whereby physical aggression affects marital outcomes due to its effects on how spouses ask for and provide support to one another. Newlywed couples (n = 172) reported levels of physical aggression over the past year and engaged in interactions designed to elicit social support; marital adjustment, and stability were assessed periodically over the first 10 years of marriage. Multilevel modeling revealed that negative support behavior mediated the relationship between physical aggression and 10-year marital adjustment levels whereas positive support behavior mediated the relationship between physical aggression and divorce status. These findings emphasize the need to look beyond conflict when explaining how aggression affects relationships and when working with couples with a history of physical aggression who are seeking to improve their relationships. (c) 2015 APA, all rights reserved).

  11. Fabrication and characterization of MCC (Materials Characterization Center) approved testing material: ATM-10 glass

    Energy Technology Data Exchange (ETDEWEB)

    Maupin, G.D.; Bowen, W.M.; Daniel, J.L.

    1988-04-01

    The Materials Characterization Center ATM-10 glass represents a reference commercial high-level waste form similar to that which will be produced by the West Valley Nuclear Service Co. Inc., West Valley, New York. The target composition and acceptable range of composition were defined by the sponsor, West Valley Nuclear Service. The ATM-10 glass was produced in accordance with the Pacific Northwest Laboratory QA Manual for License-Related Programs, MCC technical procedures, and MCC QA Plan that were in effect during the course of the work. The method and procedure to be used in the fabrication and characterization of the ATM-10 glass were specified in two run plans for glass preparation and a characterization plan. All of the ATM-10 glass was produced in the form of bars 1.9 /times/ 1.9 /times/ 10 cm nominal size, and 93 g nominal mass. A total of 15 bars of ATM-10 glass weighing 1394 g was produced. The production bars were characterized to determine the mean composition, oxidation state, and microstructure of the ATM-10 product. Table A summarizes the characterization results. The ATM-10 glass meets all specifications. The elemental composition and oxidation state of the glass are within the specifications of the client. Visually, the ATM-10 glass bars appear uniformly glassy and generally without exterior features. Microscopic examination revealed low (less than 2 wt %) concentractions of 3-..mu..m iron-chrome (suspected spinel) crystals and /approximately/0.5-..mu..m ruthenium inclusions scattered randomly throughout the glassy matrix. Closed porosity, with pores ranging in diameter from 5 to 250 ..mu..m, was observed in all samples. 4 refs., 10 figs., 21 tabs.

  12. Fabrication and characterization of MCC [Materials Characterization Center] approved testing material: ATM-10 glass

    International Nuclear Information System (INIS)

    Maupin, G.D.; Bowen, W.M.; Daniel, J.L.

    1988-04-01

    The Materials Characterization Center ATM-10 glass represents a reference commercial high-level waste form similar to that which will be produced by the West Valley Nuclear Service Co. Inc., West Valley, New York. The target composition and acceptable range of composition were defined by the sponsor, West Valley Nuclear Service. The ATM-10 glass was produced in accordance with the Pacific Northwest Laboratory QA Manual for License-Related Programs, MCC technical procedures, and MCC QA Plan that were in effect during the course of the work. The method and procedure to be used in the fabrication and characterization of the ATM-10 glass were specified in two run plans for glass preparation and a characterization plan. All of the ATM-10 glass was produced in the form of bars 1.9 /times/ 1.9 /times/ 10 cm nominal size, and 93 g nominal mass. A total of 15 bars of ATM-10 glass weighing 1394 g was produced. The production bars were characterized to determine the mean composition, oxidation state, and microstructure of the ATM-10 product. Table A summarizes the characterization results. The ATM-10 glass meets all specifications. The elemental composition and oxidation state of the glass are within the specifications of the client. Visually, the ATM-10 glass bars appear uniformly glassy and generally without exterior features. Microscopic examination revealed low (less than 2 wt %) concentractions of 3-μm iron-chrome (suspected spinel) crystals and /approximately/0.5-μm ruthenium inclusions scattered randomly throughout the glassy matrix. Closed porosity, with pores ranging in diameter from 5 to 250 μm, was observed in all samples. 4 refs., 10 figs., 21 tabs

  13. Characterization of aqueous silver nitrate solutions for leakage tests

    Directory of Open Access Journals (Sweden)

    José Ferreira Costa

    2011-06-01

    Full Text Available OBJECTIVE: To determine the pH over a period of 168 h and the ionic silver content in various concentrations and post-preparation times of aqueous silver nitrate solutions. Also, the possible effects of these factors on microleakage test in adhesive/resin restorations in primary and permanent teeth were evaluated. MATERIAL AND METHODS: A digital pHmeter was used for measuring the pH of the solutions prepared with three types of water (purified, deionized or distilled and three brands of silver nitrate salt (Merck, Synth or Cennabras at 0, 1, 2, 24, 48, 72, 96 and 168 h after preparation, and storage in transparent or dark bottles. Ionic silver was assayed according to the post-preparation times (2, 24, 48, 72, 96, 168 h and concentrations (1, 5, 25, 50% of solutions by atomic emission spectrometry. For each sample of each condition, three readings were obtained for calculating the mean value. Class V cavities were prepared with enamel margins on primary and permanent teeth and restored with the adhesive systems OptiBond FL or OptiBond SOLO Plus SE and the composite resin Filtek Z-250. After nail polish coverage, the permanent teeth were immersed in 25% or 50% AgNO3 solution and the primary teeth in 5% or 50% AgNO3 solutions for microleakage evaluation. ANOVA and the Tukey's test were used for data analyses (α=5%. RESULTS: The mean pH of the solutions ranged from neutral to alkaline (7.9±2.2 to 11.8±0.9. Mean ionic silver content differed depending on the concentration of the solution (4.75±0.5 to 293±15.3 ppm. In the microleakage test, significant difference was only observed for the adhesive system factor (p=0.000. CONCLUSIONS: Under the tested experimental conditions and based on the obtained results, it may be concluded that the aqueous AgNO3 solutions: have neutral/alkaline pH and service life of up to 168 h; the level of ionic silver is proportional to the concentration of the solution; even at 5% concentration, the solutions were

  14. Characterization and durability testing of a glass-bonded ceramic waste form

    International Nuclear Information System (INIS)

    Johnson, S. G.

    1998-01-01

    Argonne National Laboratory is developing a glass bonded ceramic waste form for encapsulating the fission products and transuranics from the conditioning of metallic reactor fuel. This waste form is currently being scaled to the multi-kilogram size for encapsulation of actual high level waste. This paper will present characterization and durability testing of the ceramic waste form. An emphasis on results from application of glass durability tests such as the Product Consistency Test and characterization methods such as X-ray diffraction and scanning electron microscopy. The information presented is based on a suite of tests utilized for assessing product quality during scale-up and parametric testing

  15. Social and Physical Characterization of Urban Contexts: Techniques and Methods for Quantification, Classification and Purposive Sampling

    Directory of Open Access Journals (Sweden)

    Miguel Serra

    2018-03-01

    Full Text Available Robust quantitative descriptions of the social and physical characteristics of urban contexts are essential for assessing the impacts of urban environments on other, potentially dependent variables. Common methodologies used for that purpose, however, are either coarse or suffer from biasing effects. At the social level, the use of indicators encoded into pre-defined areal units, makes results prone to the Modifiable Areal Unit Problem. At the physical level, the adopted morphological indicators are usually highly aggregated descriptors of urban form. Moreover, there is a lack of explicit methodologies for the purposive sampling of urban contexts with specific combinations of social and physical characteristics, which—we argue—may be more effective than probabilistic sampling, when exploring phenomena as elusive as the effects of urban contextual factors. This article presents a set of GIS-based methods for addressing these issues, based on: a local indicators of spatial association; b detailed quantitative morphological descriptions, coupled with unsupervised classification techniques; and c purposive sampling strategies carried out on the data generated by the proposed context characterization methods (a and b. The methods are illustrated through the characterization of the urban contexts of the 77 state-sector secondary schools in Liverpool, but are generalizable across all categories of urban objects and are independent of the geographical context of implementation.

  16. Global Threat Reduction Initiative Fuel-Thermo-Physical Characterization Project Quality Assurance Plan

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Mario M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Slonecker, Bruce D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2012-06-01

    The charter of the Fuel Thermo-Physical Characterization Project is to ready Pacific Northwest National Laboratory (PNNL) facilities and processes for the receipt of unirradiated and irradiated low enriched uranium (LEU) molybdenum (U-Mo) fuel element samples, and to perform analysis to support the Global Threat Reduction Initiative conversion program. PNNL’s support for the program will include the establishment of post-irradiation examination processes, including thermo-physical properties, unique to the U.S. Department of Energy laboratories. These processes will ultimately support the submission of the base fuel qualification (BFQ) to the U.S. Nuclear Regulatory Commission (NRC) and revisions to High Performance Research Reactor Safety Analysis Reports to enable conversion from highly enriched uranium to LEU fuel. This quality assurance plan (QAP) provides the quality assurance requirements and processes that support the NRC BFQ. This QAP is designed to be used by project staff, and prescribes the required management control elements that are to be met and how they are implemented. Additional controls are captured in Fuel Thermo-Physical Characterization Project plans, existing procedures, and procedures to be developed that provide supplemental information on how work is conducted on the project.

  17. Social and environmental determinants of physical activity in urban parks: Testing a neighborhood disorder model.

    Science.gov (United States)

    Douglas, Jason A; Briones, Maya D; Bauer, Eliane Z; Trujillo, Melissa; Lopez, Melissa; Subica, Andrew M

    2018-01-31

    The current study examined the nexus of neighborhood disorder-in the form of physical disorder (e.g., broken glass and vandalism) and social disorder (e.g., public drinking and lewd conduct)-and physical activity (PA) in urban public parks to inform public policy addressing chronic disease in at-risk populations. Five hundred and twenty-two unique observations were conducted in 22 public parks from March to September 2016. The study utilized the System for Observing Play and Recreation in Communities (SOPARC) to document age, gender, ethnicity, and PA level of park users. The Physical Activity Resource Assessment (PARA) was used to document observed physical and social disorder incivilities in public parks included in the current study. Males, adults, and Latina/os accounted for the largest number of park users, respectively. Significant PA differences were observed across gender, age, and ethnicity. Multiple linear regression controlling for gender, age, and ethnicity found physical disorder, but not social disorder, generally predicted PA reductions. While it has been demonstrated that physical disorder predicts PA reductions in low-income communities of color, this is the first study to reveal that physical disorder may lead to decreased PA in urban public parks. Thus, remediation of public park incivilities characterized by physical disorder, paired with community outreach, may lead to increased PA in at-risk communities. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Characterization of irradiated test structures for the CMS tracker upgrade

    Science.gov (United States)

    Lutzer, Bernhard

    2013-12-01

    The CMS collaboration is currently conducting a campaign to identify radiation-hard materials for an upgrade of the CMS tracker. This upgrade is needed to be able to cope with the higher radiation background of the future HL-LHC; additionally the performance of the current tracker will be significantly degraded at the time of the upgrade, requiring a replacement. Several different test structures (TSs) and sensors have been designed for a 6 in. wafer layout. These wafers were produced by an industrial supplier (Hamamatsu Photonics K.K.) and differ by their bulk material (Float Zone, Magnetic Czochralski and CVD-Epi), thickness (from 50 μm to 320 μm) and N-P type doping. These TSs consist of different microelectronic devices including diodes, resistors or MOS structures. They enable the extraction of parameters which are not accessible in a silicon detector and allow the assessment of the quality of the sensors produced on the same wafer. The TSs have been irradiated with protons and neutrons to emulate the radiation damage caused by the particle fluence inside the future CMS tracker after 10 years of operation. This contribution will present measurements of non-irradiated and irradiated test structures at different fluences. The changes of the properties of the microelectronic devices will be discussed as well as the design of the TSs.

  19. MO-AB-206-00: Nuclear Medicine Physics and Testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    This education session will cover the physics and operation principles of gamma cameras and PET scanners. The first talk will focus on PET imaging. An overview of the principles of PET imaging will be provided, including positron decay physics, and the transition from 2D to 3D imaging. More recent advances in hardware and software will be discussed, such as time-of-flight imaging, and improvements in reconstruction algorithms that provide for options such as depth-of-interaction corrections. Quantitative applications of PET will be discussed, as well as the requirements for doing accurate quantitation. Relevant performance tests will also be described. Learning Objectives: Be able to describe basic physics principles of PET and operation of PET scanners. Learn about recent advances in PET scanner hardware technology. Be able to describe advances in reconstruction techniques and improvements Be able to list relevant performance tests. The second talk will focus on gamma cameras. The Nuclear Medicine subcommittee has charged a task group (TG177) to develop a report on the current state of physics testing of gamma cameras, SPECT, and SPECT/CT systems. The report makes recommendations for performance tests to be done for routine quality assurance, annual physics testing, and acceptance tests, and identifies those needed satisfy the ACR accreditation program and The Joint Commission imaging standards. The report is also intended to be used as a manual with detailed instructions on how to perform tests under widely varying conditions. Learning Objectives: At the end of the presentation members of the audience will: Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of gamma cameras for planar imaging. Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of SPECT systems. Be familiar with the tests of a SPECT/CT system that include the CT images

  20. An Experimental Test of Parenting Practices as a Mediator of Early Childhood Physical Aggression

    Science.gov (United States)

    Brotman, Laurie Miller; O'Neal, Colleen R.; Huang, Keng-Yen; Gouley, Kathleen Kiely; Rosenfelt, Amanda; Shrout, Patrick E.

    2009-01-01

    Background: Parenting practices predict early childhood physical aggression. Preventive interventions that alter parenting practices and aggression during early childhood provide the opportunity to test causal models of early childhood psychopathology. Although there have been several informative preventive intervention studies that test mediation…

  1. Self-Paced Physics, Documentation Report, Test Item Bank 5.3.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    As a supplement to the principal reports, a compilation of criterion check items and diagnostic test items identified by terminal objectives is presented in this document relating to the U. S. Naval Academy Self-Paced Physics Course. Included are a progress check item bank, student terminal objective key sheets, quarterly diagnostic tests and…

  2. Top 10 Research Questions Related to Musculoskeletal Physical Fitness Testing in Children and Adolescents

    Science.gov (United States)

    Plowman, Sharon Ann

    2014-01-01

    The purpose of this article is to bring attention to the 10 most pressing questions relevant to musculoskeletal physical fitness testing in children and adolescents. The goal is to stimulate research to answer these questions. The most pressing needs include establishing definitive links between valid, reliable, and feasible field test measures of…

  3. Characterization and testing of EJ-309 and Stilbene scintillation detectors

    Science.gov (United States)

    Baramsai, B.; Jandel, M.; Bredeweg, T. A.; Couture, A.; Mosby, S.; Rusev, G.; Ullmann, J. L.; Walker, C. L.

    2015-09-01

    A new neutron detector array (NEUANCE) is under development at the Los Alamos Neutron Science Center (LANSCE). After completion, NEUANCE will be installed in the central cavity of the 3.6π Υ-ray detector array DANCE located at the Lujan Center of LANSCE. The detector system, with simultaneous neutron and -ray detection capability, will be used to study neutron-induced capture and session reactions. The response of a EJ-309 scintillation detector to Υ-ray and neutron radiation was measured using the standard Υ-ray and 252Cf sources. The light from the detector was collected using a Hamamatsu photomultiplier tube or a Silicon photomultiplier GEANT4 was used to understand the light output and the optical photon transport in the scintillation. The detector geometry and optimum parameters for the data acquisition system were determined based on the test results and the simulations.

  4. RTM370 Polyimide Braided Composites: Characterization and Impact Testing

    Science.gov (United States)

    Chuang, Kathy C.; Revilock, Duane M.; Ruggeri, Charles R.; Criss, Jim M., Jr.; Mintz, Eric A.

    2013-01-01

    RTM370 imide oligomer based on 2,3,3',4'-biphenyl dianhydride (a-BPDA), 3,4'-oxydianiline (3,4'-ODA) and terminated with the 4-phenylethynylphthalic (PEPA) endcap has been shown to exhibit a low melt viscosity (10-30 poise) at 280 C with a pot-life of 1-2 h and a high cured glass transition temperature (Tg) of 370 C. RTM370 resin has been successfully fabricated into composites reinforced with T650-35 carbon fabrics by resin transfer molding (RTM). RTM370 composites display excellent mechanical properties up to 327 C (620 F), and outstanding property retention after aging at 288degC (550 F) for 1000 h, and under hot-wet conditions. In ballistic impact testing, RTM370 triaxial braided T650-35 carbon fiber composites exhibited enhanced energy absorption at 288 C (550 F) compared to ambient temperature.

  5. Microstructural characterization of Charpy-impact-tested nanostructured bainite

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, Y.T.; Chang, H.T.; Huang, B.M. [Department of Materials Science and Engineering, National Taiwan University, Taipei 10617, Taiwan, ROC (China); Huang, C.Y. [Iron and Steel R& D Department, China Steel Corporation, Kaohsiung, Taiwan, ROC (China); Yang, J.R., E-mail: jryang@ntu.edu.tw [Department of Materials Science and Engineering, National Taiwan University, Taipei 10617, Taiwan, ROC (China)

    2015-09-15

    In this work, a possible cause of the extraordinary low impact toughness of nanostructured bainite has been investigated. The microstructure of nanostructured bainite consisted chiefly of carbide-free bainitic ferrite with retained austenite films. X-ray diffractometry (XRD) measurement indicated that no retained austenite existed in the fractured surface of the Charpy-impact-tested specimens. Fractographs showed that cracks propagated mainly along bainitic ferrite platelet boundaries. The change in microstructure after impact loading was verified by transmission electron microscopy (TEM) observations, confirming that retained austenite was completely transformed to strain-induced martensite during the Charpy impact test. However, the zone affected by strained-induced martensite was found to be extremely shallow, only to a depth of several micrometers from the fracture surface. It is appropriately concluded that upon impact, as the crack forms and propagates, strain-induced martensitic transformation immediately occurs ahead of the advancing crack tip. The successive martensitic transformation profoundly facilitates the crack propagation, resulting in the extremely low impact toughness of nanostructured bainite. Retained austenite, in contrast to its well-known beneficial role, has a deteriorating effect on toughness during the course of Charpy impact. - Highlights: • The microstructure of nanostructured bainite consisted of nano-sized bainitic ferrite subunits with retained austenite films. • Special sample preparations for SEM, XRD and TEM were made, and the strain-affected structures have been explored. • Retained austenite films were found to transform into martensite after impact loading, as evidenced by XRD and TEM results. • The zone of strain-induced martensite was found to extend to only several micrometers from the fracture surface. • The poor Charpy impact toughness is associated with the fracture of martensite at a high strain rate during

  6. Association between physiological falls risk and physical performance tests among community-dwelling older adults

    Directory of Open Access Journals (Sweden)

    Singh DK

    2015-08-01

    Full Text Available Devinder KA Singh,1 Sharmila GK Pillai,1 Sin Thien Tan,1 Chu Chiau Tai,1 Suzana Shahar2 1Physiotherapy Programme, School of Rehabilitation Sciences, 2Nutrition and Dietetics Programme, School of Healthcare Sciences, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Jalan Raja Muda Abdul Aziz, Kuala Lumpur, Malaysia Background: Physical performance and balance declines with aging and may lead to increased risk of falls. Physical performance tests may be useful for initial fall-risk screening test among community-dwelling older adults. Physiological profile assessment (PPA, a composite falls risk assessment tool is reported to have 75% accuracy to screen for physiological falls risk. PPA correlates with Timed Up and Go (TUG test. However, the association between many other commonly used physical performance tests and PPA is not known. The aim of the present study was to examine the association between physiological falls risk measured using PPA and a battery of physical performance tests.Methods: One hundred and forty older adults from a senior citizens club in Kuala Lumpur, Malaysia (94 females, 46 males, aged 60 years and above (65.77±4.61, participated in this cross-sectional study. Participants were screened for falls risk using PPA. A battery of physical performance tests that include ten-step test (TST, short physical performance battery (SPPB, functional reach test (FRT, static balance test (SBT, TUG, dominant hand-grip strength (DHGS, and gait speed test (GST were also performed. Spearman’s rank correlation and binomial logistic regression were performed to examine the significantly associated independent variables (physical performance tests with falls risk (dependent variable.Results: Approximately 13% older adults were at high risk of falls categorized using PPA. Significant differences (P<0.05 were demonstrated for age, TST, SPPB, FRT, SBT, TUG between high and low falls risk group. A significant (P<0.01 weak correlation

  7. Physical properties of VNTR data, and their impact on a test of allelic independence

    Energy Technology Data Exchange (ETDEWEB)

    Devlin, B.; Risch, N. (Yale Univ., New Haven, CT (United States))

    1993-08-01

    In this article the authors describe the physical properties of VNTR data, as well as their effects on the two-dimensional distribution of fragment pairs. Tests of independence of alleles at a locus may confound those physical properties with allele independence. A recently proposed test by Geisser and Johnson is an example. The authors show that alleles can be strictly independent, yet the proposed test suggests large violations of allele independence because it is sensitive to well-known electrophoretic phenomena. 7 refs., 4 tabs.

  8. Preliminary analyses for HTTR's start-up physics tests by Monte Carlo code MVP

    International Nuclear Information System (INIS)

    Nojiri, Naoki; Nakano, Masaaki; Ando, Hiroei; Fujimoto, Nozomu; Takeuchi, Mitsuo; Fujisaki, Shingo; Yamashita, Kiyonobu

    1998-08-01

    Analyses of start-up physics tests for High Temperature Engineering Test Reactor (HTTR) have been carried out by Monte Carlo code MVP based on continuous energy method. Heterogeneous core structures were modified precisely, such as the fuel compacts, fuel rods, coolant channels, burnable poisons, control rods, control rod insertion holes, reserved shutdown pellet insertion holes, gaps between graphite blocks, etc. Such precise modification of the core structures was difficult with diffusion calculation. From the analytical results, the followings were confirmed; The first criticality will be achieved around 16 fuel columns loaded. The reactivity at the first criticality can be controlled by only one control rod located at the center of the core with other fifteen control rods fully withdrawn. The excess reactivity, reactor shutdown margin and control rod criticality positions have been evaluated. These results were used for planning of the start-up physics tests. This report presents analyses of start-up physics tests for HTTR by MVP code. (author)

  9. Diagnostic accuracy of scapular physical examination tests for shoulder disorders: a systematic review.

    Science.gov (United States)

    Wright, Alexis A; Wassinger, Craig A; Frank, Mason; Michener, Lori A; Hegedus, Eric J

    2013-09-01

    To systematically review and critique the evidence regarding the diagnostic accuracy of physical examination tests for the scapula in patients with shoulder disorders. A systematic, computerised literature search of PubMED, EMBASE, CINAHL and the Cochrane Library databases (from database inception through January 2012) using keywords related to diagnostic accuracy of physical examination tests of the scapula. The Quality Assessment of Diagnostic Accuracy Studies tool was used to critique the quality of each paper. Eight articles met the inclusion criteria; three were considered to be of high quality. Of the three high-quality studies, two were in reference to a 'diagnosis' of shoulder pain. Only one high-quality article referenced specific shoulder pathology of acromioclavicular dislocation with reported sensitivity of 71% and 41% for the scapular dyskinesis and SICK scapula test, respectively. Overall, no physical examination test of the scapula was found to be useful in differentially diagnosing pathologies of the shoulder.

  10. Identifying and Characterizing Discrepancies Between Test and Analysis Results of Compression-Loaded Panels

    Science.gov (United States)

    Thornburgh, Robert P.; Hilburger, Mark W.

    2005-01-01

    Results from a study to identify and characterize discrepancies between validation tests and high-fidelity analyses of compression-loaded panels are presented. First, potential sources of the discrepancies in both the experimental method and corresponding high-fidelity analysis models were identified. Then, a series of laboratory tests and numerical simulations were conducted to quantify the discrepancies and develop test and analysis methods to account for the discrepancies. The results indicate that the discrepancies between the validation tests and high-fidelity analyses can be attributed to imperfections in the test fixture and specimen geometry; test-fixture-induced changes in specimen geometry; and test-fixture-induced friction on the loaded edges of the test specimen. The results also show that accurate predictions of the panel response can be obtained when these specimen imperfections and edge conditions are accounted for in the analysis. The errors in the tests and analyses, and the methods used to characterize these errors are presented.

  11. Hip joint pathology: relationship between patient history, physical tests, and arthroscopy findings in clinical practice.

    Science.gov (United States)

    Tijssen, M; van Cingel, R E H; de Visser, E; Hölmich, P; Nijhuis-van der Sanden, M W G

    2017-03-01

    The purpose of this retrospective cohort study was to (a) describe the clinical presentation of femoroacetabular impingement (FAI) and hip labral pathology; (b) describe the accuracy of patient history and physical tests for FAI and labral pathology as confirmed by hip arthroscopy. Patients (18-65 years) were included if they were referred to a physical therapist to gather pre-operative data and were then diagnosed during arthroscopy. Results of pre-operative patient history and physical tests were collected and compared to arthroscopy. Data of 77 active patients (mean age: 37 years) were included. Groin as main location of pain, the Anterior Impingement test (AIT), Flexion-Abduction-External Rotation (FABER) test, and Fitzgerald test had a high sensitivity (range 0.72-0.91). Sensitivity increased when combining these tests (0.97) as either groin as main location of pain and a positive FABER test or a positive AIT and a positive FABER test were the shortest most sensitive combinations. The results of this study point out that in clinical practice absence of groin as main location of pain combined with a negative FABER test or the combination of a negative AIT and a negative FABER test are suggested to rule out the diagnosis of symptomatic FAI and/or labral pathology. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Reliability of health-related physical fitness tests in adolescents: the MOVE Program.

    Science.gov (United States)

    Vanhelst, Jérémy; Béghin, Laurent; Fardy, Paul S; Ulmer, Zekya; Czaplicki, Grégory

    2016-03-01

    The aim was to examine the reliability of health-related physical fitness tests that were used in a French health promotion program 'Move…A priority for your health'. Participants were 174 French youth (88 children and 86 adolescents) aged 8·2-16·2 years. Aerobic fitness, muscular strength, speed and flexibility were tested using 20-m shuttle run test, ½ mile run test, basketball throw, standing long jump, shoulder stretch and 20/30/50-m sprint tests. Reliability was calculated for the basketball throw, standing long jump, shoulder stretch and sprint tests. The tests were performed two times, 1 week apart on the same day of the week. Reliability was examined with intraclass correlation coefficients (ICCs) and Bland-Altman analysis. With the exception of the ½ mile run test, which resulted in moderate agreement (0·66), all tests had high reliability. ICCs were 0·97, 0·93, 0·91 and 0·93 for the sprint test, basketball throw, shoulder stretch and the standing long jump, respectively. The differences obtained between the first and the second trial were non-significant. Results from this study indicate that the BOUGE health-related physical fitness battery, administrated by physical education teachers, was reliable for measuring health-related components of fitness in children and adolescents in a school setting. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  13. Preparation and Characterization of Latex Particles as Potential Physical Shale Stabilizer in Water-Based Drilling Fluids

    Directory of Open Access Journals (Sweden)

    Junyi Liu

    2014-01-01

    Full Text Available The poly(styrene-methyl methacrylate latex particles as potential physical shale stabilizer were successfully synthesized with potassium persulfate as an initiator in isopropanol-water medium. The synthesized latex particles were characterized by Fourier transform infrared spectroscopy (FT-IR, particle size distribution measurement (PSD, transmission electron microscopy (TEM, and thermal gravimetric analysis (TGA. FT-IR and TGA analysis confirmed that the latex particles were prepared by polymerization of styrene and methyl methacrylate and maintained good thermal stability. TEM and PSD analysis indicated that the spherical latex particles possessed unimodal distribution from 80 nm to 345 nm with the D90 value of 276 nm. The factors influencing particle size distribution (PSD of latex particles were also discussed in detail. The interaction between latex particles and natural shale cores was investigated quantitatively via pore pressure transmission tests. The results indicated that the latex particles as potential physical shale stabilizer could be deformable to bridge and seal the nanopores and microfractures of shale to reduce the shale permeability and prevent pore pressure transmission. What is more, the latex particles as potential physical shale stabilizer work synergistically with chemical shale stabilizer to impart superior shale stability.

  14. Preparation and characterization of latex particles as potential physical shale stabilizer in water-based drilling fluids.

    Science.gov (United States)

    Liu, Junyi; Qiu, Zhengsong; Huang, Wei'an; Song, Dingding; Bao, Dan

    2014-01-01

    The poly(styrene-methyl methacrylate) latex particles as potential physical shale stabilizer were successfully synthesized with potassium persulfate as an initiator in isopropanol-water medium. The synthesized latex particles were characterized by Fourier transform infrared spectroscopy (FT-IR), particle size distribution measurement (PSD), transmission electron microscopy (TEM), and thermal gravimetric analysis (TGA). FT-IR and TGA analysis confirmed that the latex particles were prepared by polymerization of styrene and methyl methacrylate and maintained good thermal stability. TEM and PSD analysis indicated that the spherical latex particles possessed unimodal distribution from 80 nm to 345 nm with the D90 value of 276 nm. The factors influencing particle size distribution (PSD) of latex particles were also discussed in detail. The interaction between latex particles and natural shale cores was investigated quantitatively via pore pressure transmission tests. The results indicated that the latex particles as potential physical shale stabilizer could be deformable to bridge and seal the nanopores and microfractures of shale to reduce the shale permeability and prevent pore pressure transmission. What is more, the latex particles as potential physical shale stabilizer work synergistically with chemical shale stabilizer to impart superior shale stability.

  15. Construction and characterization of external cavity diode lasers for atomic physics.

    Science.gov (United States)

    Hardman, Kyle S; Bennetts, Shayne; Debs, John E; Kuhn, Carlos C N; McDonald, Gordon D; Robins, Nick

    2014-04-24

    Since their development in the late 1980s, cheap, reliable external cavity diode lasers (ECDLs) have replaced complex and expensive traditional dye and Titanium Sapphire lasers as the workhorse laser of atomic physics labs. Their versatility and prolific use throughout atomic physics in applications such as absorption spectroscopy and laser cooling makes it imperative for incoming students to gain a firm practical understanding of these lasers. This publication builds upon the seminal work by Wieman, updating components, and providing a video tutorial. The setup, frequency locking and performance characterization of an ECDL will be described. Discussion of component selection and proper mounting of both diodes and gratings, the factors affecting mode selection within the cavity, proper alignment for optimal external feedback, optics setup for coarse and fine frequency sensitive measurements, a brief overview of laser locking techniques, and laser linewidth measurements are included.

  16. Characterization of study focus of the Brazilian academic-scientific production about experimentation in Physics Teaching

    Science.gov (United States)

    Wesendonk, F. S.; Terrazzan, E. A.

    2016-12-01

    In this article, we presented a characterization of the recent academic and scientific literature on experiments in Physics Education in terms of focus and research intentions and results built through these investigations. For this, we used as a source of information 10 national Academic and Scientific Journals available on websites. By consulting these journals, we identified that 147 papers published from 2009 to 2013 had as their main focus the experimental research. We classified the Works in categories established a priori and subcategories established a posteriori. At the end, we found out that few articles deal with this issue (9%). Moreover, in most productions there is a superficial discussion of theoretical studies on the use of experimentation in teaching. This makes the contribution of these productions for the development of conceptual discussions about the potential and limited use of experimentation in Physics Education to be relatively small.

  17. Obtaining and characterization catalyst Ki/Al2O3 by physical dispersion process via wet

    International Nuclear Information System (INIS)

    Silva, M.C. da; Dantas, J.; Costa, A.C.F.M.; Costa, N.C.O.; Freitas, N.L. de

    2014-01-01

    The aim of this study is the Obtention and characterization of catalysts being supported alumina impregnated with KI by physical dispersion in wet via attritor mill in periods of 30 and 60 minutes. Before and after impregnation the catalysts were characterized by XRD, X ray fluorescence, particle size distribution, textural analysis (BET). The results show the presence of the stable crystalline phase Al 2 O 3 in all samples after impregnation and the second phase formed from KI and K 2 O. There was a decrease in the agglomerates incorporated with the potassium due to the milling process. It was observed that the highest specific surface area was obtained by the impregnated sample into a 60 min. (author)

  18. Characterization of tissue-equivalent materials for use in construction of physical phantoms

    International Nuclear Information System (INIS)

    Souza, Edvan V. de; Oliveira, Alex C.H. de; Vieira, Jose W.; Lima, Fernando R.A.

    2013-01-01

    Phantoms are physical or computational models used to simulate the transport of ionizing radiation, their interactions with human body tissues and evaluate the deposition of energy. Depending on the application, you can build phantoms of various types and features. The physical phantoms are made of materials with behavior similar to human tissues exposed to ionizing radiation, the so-called tissue-equivalent materials. The characterization of various tissue-equivalent materials is important for the choice of materials to be used is appropriate, seeking a better cost-benefit ratio. The main objective of this work is to produce tables containing the main characteristics of tissue-equivalent materials. These tables were produced in Microsoft Office Excel. Among the main features of tissue-equivalent materials that were added to the tables, are density, chemical composition, physical state, chemical stability and solubility. The main importance of this work is to contribute to the construction of high-quality physical phantoms and avoid the waste of materials

  19. Characterization of parameters and strategies used by physical therapists in difficult mechanical ventilation weaning

    Directory of Open Access Journals (Sweden)

    Fabíola Maria Sabino Meireles

    2013-03-01

    Full Text Available Objective: To characterize the main strategies and parameters used by physical therapists in difficult mechanical ventilation weaning. Methods: Cross-sectional study including all the physical therapists working in adult Intensive Care Units in three public hospitals in Fortaleza-CE. A questionnaire with closed questions related to difficult mechanical ventilation weaning was applied, with either one or multiple answers. The data was treated with descriptive and non-parametric analysis. Results: Among the parameters mostly used by the 56 interviewed physical therapists for the difficult weaning, were found: current volume reduction (26 - 46.4% and desaturation during aspiration (17 - 30.4%. It was observed that 38 (67.9% alternate T-tube and continuous positive airway pressure (CPAP as strategies for difficult weaning, and 28 (50% reported reducing the pressure support. There was no statistical difference between the strategies used in the studied hospitals, neither correlation between strategies and parameters. Conclusion: It was found that physical therapists have been performing similar strategies, which are also shown in the literature, but this is not the case with the parameters. The parameters used are not supported by the literature.

  20. Physical-mechanical and anatomical characterization in 26-year-old Eucalyptus resinifera wood

    OpenAIRE

    Lima,Israel Luiz de; Longui,Eduardo Luiz; Freitas,Miguel Luiz Menezes; Zanatto,Antonio Carlos Scatena; Zanata,Marcelo; Florsheim,Sandra Monteiro Borges; Bortoletto Jr.,Geraldo

    2014-01-01

    In the present study, we aimed to characterize Eucalyptus resinifera wood through physical and mechanical assays and wood anatomy studies, as well as determine the relationships between the properties and anatomy of wood. We used samples collected from the area close to the bark of ten 26-year-old E. resinifera trees. We concluded that the specific gravity (Gb), compression (f c0), and shear parallel to grain (f v0) were ranked in strength classes C30, C40 and C60, respectively, and that volu...

  1. Initial characterization of the ATR [Advanced Test Reactor] Large Gamma Facility

    International Nuclear Information System (INIS)

    Schnitzler, B.G.; Rogers, J.W.

    1986-05-01

    Radiation fields in the ATR Large Gamma Facility test volume are characterized. The preliminary characterization efforts described in this report include total dose rate measurements in the facility, development of a simple methodology for calculating radiation fields from the ATR fuel element power histories, and a comparison of the measured and calculated values

  2. Characterization of California Central Coast Aquifers using Pneumatic Slug Tests

    Science.gov (United States)

    Aurelius, S.; Platt, D.; Whetsler, B.; Malama, B.

    2017-12-01

    The recent prolonged drought in California, where about 75% of the population depends to some extent ongroundwater, has led to increased stresses on the state's groundwater resources due to reduced recharge andincreased abstraction to supplement dwindling surface water supplies for irrigation and other urban uses.These factors have conspired to cause historic lows in groundwater levels, lost aquifer storage capacity dueincreased potential for land subsidence, and degraded water quality in coastal aquifers faced with increasedrates of seawater intrusion. Groundwater accounts for about a third of the total water uses in California,with some coastal communities being 100% dependent on groundwater. Irrigation accounts for over 60%of all state groundwater withdrawals in California. In light of this, the state of California recently passedthe Sustainable Groundwater Management Act (SGMA) aimed at bringing the State's groundwater basinsinto sustainable regimes of abstraction, recharge and storage. Groundwater ow models are critical to thesuccessful implementation of the SGMA legislation. However, the usefulness of the models is severely limitedby a lack of detailed knowledge of aquifer properties at spatial scales that allow for accurate projections tobe made about groundwater basin sustainability by resource managers. We report here the results of highresolution pneumatic slug tests performed in two shallow aquifers in San Luis Obispo County on the CaliforniaCentral Coast to obtain detailed information about aquifer properties, including permeability and storage,and their spatial variability.

  3. Characterization of Solder Joint Reliability Using Cyclic Mechanical Fatigue Testing

    Science.gov (United States)

    Kim, Choong-Un; Bang, Woong-Ho; Xu, Huili; Lee, Tae-Kyu

    2013-10-01

    This article summarizes the mechanics of two mechanical fatigue methods, cyclic bending fatigue and shear fatigue, in inducing failure in solder joints in package assemblies, and it presents the characteristics of fatigue failures resulting from these methods using example cases of Sn-Pb eutectic and Sn-rich Pb-free solder alloys. Numerical simulation suggests that both testing configurations induce fatigue failure by the crack-opening mode. In the case of bending fatigue, the strain induced by the bending displacement is found to be sensitive to chip geometry, and it induces fatigue cracks mainly at the solder matrix adjacent to the printed circuit board interface. In case of shear fatigue, the failure location is firmly fixed at the solder neck, created by solder mask, where an abrupt change in the solder geometry occurs. Both methods conclude that the Coffin-Manson model is the most appropriate model for the isothermal mechanical fatigue of solder alloys. An analysis of fatigue characteristics using the frame of the Coffin-Manson model produces several insightful results, such as the reason why Pb-free alloys show higher fatigue resistance than Sn-Pb alloys even if they are generally more brittle. Our analysis suggests that it is related to higher work hardening. All these results indicate that mechanical fatigue can be an extremely useful method for fast screening of defective package structures and also in gaining a better understanding of fatigue failure mechanism and prediction of reliability in solder joints.

  4. Standard tests for the characterization of roofing slate pathologies

    Directory of Open Access Journals (Sweden)

    Cárdenes, V.

    2012-06-01

    Full Text Available The pathologies formed in slate roofs are mainly due to the presence of potentially unstable minerals (iron sulfides, carbonates and organic matter. These minerals may become altered by the effect of environmental agents, once the slate roof is finished. The pathologies are mainly associated with oxidation and gypsification processes of the cited mineral phases. In this work, the potential pathologies of several Spanish roofing slates are identified, using the tests defined in the European Norms EN 12326:2005, 14147:2004 and 11597:2007.

    Las patologías que se originan en pizarra para cubiertas son debidas fundamentalmente a la presencia de materiales alterables (sulfuros de hierro, carbonatos y materia orgánica. Estos minerales pueden llegar a alterarse por efecto de los agentes medioambientales, una vez que la pizarra es puesta en obra. Las patologías están principalmente asociadas a procesos de oxidación y yesificación de las citadas fases minerales. En este trabajo se determinan las patologías potenciales de varias pizarras para cubiertas españolas, utilizando los ensayos definidos en las normas UNE-EN 12326:2005, 14147:2004 y 11597:2007.

  5. Characterization Test Procedures for Intersection Collision Avoidance Systems Based on Vehicle-to-Vehicle Communications

    Science.gov (United States)

    2015-12-01

    Characterization test procedures have been developed to quantify the performance of intersection collision avoidance (ICA) systems based on vehicle-to-vehicle communications. These systems warn the driver of an imminent crossing-path collision at a r...

  6. Characterization of cracking in Strain-Hardening Cementitious Composites using the compact tension test

    DEFF Research Database (Denmark)

    Pereira, Eduardo B.; Fischer, Gregor; Barros, Joaquim A. O.

    The characterization of the tensile behavior of strain hardening cementitious composites (SHCC) is of significant importance to the material design. In a previous work the tensile stress-crack opening response of different types of SHCC was characterized using notched specimens tested in direct...... tension, where a single crack was obtained and mechanically characterized by performing Single Crack Tension Test (SCTT). In this study the tensile behavior of SHCC materials is characterized under eccentric tensile load using the Compact Tension Test (CTT). The long edge notch placed in the rectangular...... results are discussed and compared to the numerically derived responses. The tensile load-displacement responses observed in the CTTs were simulated using the cohesive crack model. The tensile stress-crack opening behaviors previously obtained with the SCTT tests were utilized to derive the traction...

  7. Methods for the physical characterization and quantification of extracellular vesicles in biological samples.

    Science.gov (United States)

    Rupert, Déborah L M; Claudio, Virginia; Lässer, Cecilia; Bally, Marta

    2017-01-01

    Our body fluids contain a multitude of cell-derived vesicles, secreted by most cell types, commonly referred to as extracellular vesicles. They have attracted considerable attention for their function as intercellular communication vehicles in a broad range of physiological processes and pathological conditions. Extracellular vesicles and especially the smallest type, exosomes, have also generated a lot of excitement in view of their potential as disease biomarkers or as carriers for drug delivery. In this context, state-of-the-art techniques capable of comprehensively characterizing vesicles in biological fluids are urgently needed. This review presents the arsenal of techniques available for quantification and characterization of physical properties of extracellular vesicles, summarizes their working principles, discusses their advantages and limitations and further illustrates their implementation in extracellular vesicle research. The small size and physicochemical heterogeneity of extracellular vesicles make their physical characterization and quantification an extremely challenging task. Currently, structure, size, buoyant density, optical properties and zeta potential have most commonly been studied. The concentration of vesicles in suspension can be expressed in terms of biomolecular or particle content depending on the method at hand. In addition, common quantification methods may either provide a direct quantitative measurement of vesicle concentration or solely allow for relative comparison between samples. The combination of complementary methods capable of detecting, characterizing and quantifying extracellular vesicles at a single particle level promises to provide new exciting insights into their modes of action and to reveal the existence of vesicle subpopulations fulfilling key biological tasks. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. MULTI-ATTRIBUTE SEISMIC/ROCK PHYSICS APPROACH TO CHARACTERIZING FRACTURED RESERVOIRS

    Energy Technology Data Exchange (ETDEWEB)

    Gary Mavko

    2000-10-01

    This project consists of three key interrelated Phases, each focusing on the central issue of imaging and quantifying fractured reservoirs, through improved integration of the principles of rock physics, geology, and seismic wave propagation. This report summarizes the results of Phase I of the project. The key to successful development of low permeability reservoirs lies in reliably characterizing fractures. Fractures play a crucial role in controlling almost all of the fluid transport in tight reservoirs. Current seismic methods to characterize fractures depend on various anisotropic wave propagation signatures that can arise from aligned fractures. We are pursuing an integrated study that relates to high-resolution seismic images of natural fractures to the rock parameters that control the storage and mobility of fluids. Our goal is to go beyond the current state-of-the art to develop and demonstrate next generation methodologies for detecting and quantitatively characterizing fracture zones using seismic measurements. Our study incorporates 3 key elements: (1) Theoretical rock physics studies of the anisotropic viscoelastic signatures of fractured rocks, including up scaling analysis and rock-fluid interactions to define the factors relating fractures in the lab and in the field. (2) Modeling of optimal seismic attributes, including offset and azimuth dependence of travel time, amplitude, impedance and spectral signatures of anisotropic fractured rocks. We will quantify the information content of combinations of seismic attributes, and the impact of multi-attribute analyses in reducing uncertainty in fracture interpretations. (3) Integration and interpretation of seismic, well log, and laboratory data, incorporating field geologic fracture characterization and the theoretical results of items 1 and 2 above. The focal point for this project is the demonstration of these methodologies in the Marathon Oil Company Yates Field in West Texas.

  9. REVEALING STUDENTS' COGNITIVE STRUCTURE ABOUT PHYSICAL AND CHEMICAL CHANGE: USE OF A WORD ASSOCIATION TEST

    OpenAIRE

    Hasene Esra Yildirir; Hatice Demirkol

    2018-01-01

    The current study aimed at examining the utility of a word association test in revealing students’ cognitive structure in a specific chemistry topic through a word association test. The participants were 153 6th graders in a western Turkish city. The results revealed that the word association test serves a useful purpose in exploring the students’ cognitive structure with regard to physical and chemical change and identifying their misconceptions about this topic. Some students gave irrelevan...

  10. A Complete Characterization of Potential Compensation Tests of Hicksian Welfare Measures

    OpenAIRE

    Donald Keenan; Arthur Snow

    1999-01-01

    In this paper, the authors present complete characterizations of the compensation tests for potential Pareto superiority proposed by Kaldor, Hicks, and Samuelson in terms of the aggregate Hicksian measures of income compensation, including compensating and equivalent variations. The key to obtaining these characterizations lies in recognizing that each potential compensation test entails a search over possible outcomes, rather than a comparison of only the new and original outcomes, as with s...

  11. Factors that affect the physical science career interest of female students: Testing five common hypotheses

    Science.gov (United States)

    Hazari, Zahra; Potvin, Geoff; Lock, Robynne M.; Lung, Florin; Sonnert, Gerhard; Sadler, Philip M.

    2013-12-01

    There are many hypotheses regarding factors that may encourage female students to pursue careers in the physical sciences. Using multivariate matching methods on national data drawn from the Persistence Research in Science and Engineering (PRiSE) project (n=7505), we test the following five commonly held beliefs regarding what factors might impact females’ physical science career interest: (i) having a single-sex physics class, (ii) having a female physics teacher, (iii) having female scientist guest speakers in physics class, (iv) discussing the work of female scientists in physics class, and (v) discussing the underrepresentation of women in physics class. The effect of these experiences on physical science career interest is compared for female students who are matched on several factors, including prior science interests, prior mathematics interests, grades in science, grades in mathematics, and years of enrollment in high school physics. No significant effects are found for single-sex classes, female teachers, female scientist guest speakers, and discussing the work of female scientists. However, discussions about women’s underrepresentation have a significant positive effect.

  12. Physics of Colloids in Space--Plus (PCS+) Experiment Completed Flight Acceptance Testing

    Science.gov (United States)

    Doherty, Michael P.

    2004-01-01

    The Physics of Colloids in Space--Plus (PCS+) experiment successfully completed system-level flight acceptance testing in the fall of 2003. This testing included electromagnetic interference (EMI) testing, vibration testing, and thermal testing. PCS+, an Expedite the Process of Experiments to Space Station (EXPRESS) Rack payload will deploy a second set of colloid samples within the PCS flight hardware system that flew on the International Space Station (ISS) from April 2001 to June 2002. PCS+ is slated to return to the ISS in late 2004 or early 2005.

  13. Reliability of physical examination tests for the diagnosis of knee disorders: Evidence from a systematic review.

    Science.gov (United States)

    Décary, Simon; Ouellet, Philippe; Vendittoli, Pascal-André; Desmeules, François

    2016-12-01

    Clinicians often rely on physical examination tests to guide them in the diagnostic process of knee disorders. However, reliability of these tests is often overlooked and may influence the consistency of results and overall diagnostic validity. Therefore, the objective of this study was to systematically review evidence on the reliability of physical examination tests for the diagnosis of knee disorders. A structured literature search was conducted in databases up to January 2016. Included studies needed to report reliability measures of at least one physical test for any knee disorder. Methodological quality was evaluated using the QAREL checklist. A qualitative synthesis of the evidence was performed. Thirty-three studies were included with a mean QAREL score of 5.5 ± 0.5. Based on low to moderate quality evidence, the Thessaly test for meniscal injuries reached moderate inter-rater reliability (k = 0.54). Based on moderate to excellent quality evidence, the Lachman for anterior cruciate ligament injuries reached moderate to excellent inter-rater reliability (k = 0.42 to 0.81). Based on low to moderate quality evidence, the Tibiofemoral Crepitus, Joint Line and Patellofemoral Pain/Tenderness, Bony Enlargement and Joint Pain on Movement tests for knee osteoarthritis reached fair to excellent inter-rater reliability (k = 0.29 to 0.93). Based on low to moderate quality evidence, the Lateral Glide, Lateral Tilt, Lateral Pull and Quality of Movement tests for patellofemoral pain reached moderate to good inter-rater reliability (k = 0.49 to 0.73). Many physical tests appear to reach good inter-rater reliability, but this is based on low-quality and conflicting evidence. High-quality research is required to evaluate the reliability of knee physical examination tests. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Cyber-Physical Energy Systems Modeling, Test Specification, and Co-Simulation Based Testing

    DEFF Research Database (Denmark)

    van der Meer, A. A.; Palensky, P.; Heussen, Kai

    2017-01-01

    The gradual deployment of intelligent and coordinated devices in the electrical power system needs careful investigation of the interactions between the various domains involved. Especially due to the coupling between ICT and power systems a holistic approach for testing and validating is required...

  15. Start up physics tests of units 5 and 6 (WWER 1000) at Kozloduy NPP by comparison with the calculated neutron physics characteristics

    International Nuclear Information System (INIS)

    Antov, A.; Stoyanova, I.

    2008-01-01

    In conjunction with each refuelling shutdown of the reactor core, nuclear design calculations are performed to ensure that the reactor physics characteristics of the new core will be consistent with the safety limits. Prior to return to normal operation, a physics test program is required to determine if the operating characteristics of the core are consistent with the design predictions and to ensure that the core can be operated as designed. Successful completion of the physics test program is demonstrated when the test results agree with the predicted results within predetermined test criteria. Successful completion of the physics test program and successful completion of other tests, which are performed after each refuelling provides assurance that the plant can be operated as designed. The calculated neutron-physics characteristics values of Kozloduy NPP Unit 5 and Unit 6 (WWER 1000) obtained by the computer code package KASKAD are compared with the obtained results during the start up physics tests. The core fuel loading consists of 163 fuel assemblies (FAs). The calculated values are given according to actual experimental conditions of the reactor core during start up physics tests. The report includes comparisons between calculation results by code package KASKAD (BIPR7A) and experimental data values of main neutron-physics characteristics during start up physics tests in selected recent cycles of Kozloduy NPP Unit 5 and Unit 6. (authors)

  16. NAVEL BASE VENTURA COUNTY, PORT HUENEME, CALIFORNIA EPA CHARACTERIZATION TEST CELL REPORT ON ELECTROMAGNETIC SURVEYS IN THE TEST CELL AREA

    Science.gov (United States)

    The objective of the geophysical surveys at the EPA Characterization Test Cell (CTC) area (Site) at Naval Base Ventura County, Port Hueneme, California is to locate geophysical anomalies indicative of metallic objects within the area of the cell. The goal was to provide backgroun...

  17. Physical test report to drop test of a 9975 radioactive material shipping packaging

    International Nuclear Information System (INIS)

    Blanton, P.S.

    1997-01-01

    This report presents the drop test results for the 9975 radioactive material shipping package being dropped 30 feet onto a unyielding surface followed by a 40-inch puncture pin drop. The purpose of these drops was to show that the package lid would remain attached to the drum. The 30-foot drop was designed to weaken the lid closure lug while still maintaining maximum extension of the lugs from the drum surface. This was accomplished by angling the drum approximately 30 degrees from horizontal in an inverted position. In this position, the drum was rotated slightly so as not to embed the closure lugs into the drum as a result of the 30-foot drop. It was determined that this orientation would maximize deformation to the closure ring around the closure lug while still maintaining the extension of the lugs from the package surface. The second drop was from 40 inches above a 40-inch tall 6-inch diameter puncture pin. The package was angled 10 degrees from vertical and aligned over the puncture pin to solidly hit the drum lug(s) in an attempt to disengage the lid when dropped.Tests were performed in response to DOE EM-76 review Q5 inquires that questioned the capability of the 9975 drum lid to remain in place under this test sequence. Two packages were dropped utilizing this sequence, a 9974 and 9975. Test results for the 9974 package are reported in WSRC-RP-97-00945. A series of 40-inch puncture pin tests were also performed on undamaged 9975 and 9974 packages

  18. Measurement of talent in team handball: the questionable use of motor and physical tests.

    Science.gov (United States)

    Lidor, Ronnie; Falk, Bareket; Arnon, Michal; Cohen, Yoram; Segal, Gil; Lander, Yael

    2005-05-01

    Testing for selection is one of the most important fundamentals in any multistep sport program. In most ball games, coaches assess motor, physical, and technical skills on a regular basis in early stages of talent identification and development. However, selection processes are complex, are often unstructured, and lack clear-cut theory-based knowledge. For example, little is known about the relevance of the testing process to the final selection of the young prospects. The purpose of this study was to identify motor, physical, and skill variables that could provide coaches with relevant information in the selection process of young team handball players. In total, 405 players (12-13 years of age at the beginning of the testing period) were recommended by their coaches to undergo a battery of tests prior to selection to the Junior National Team. This number is the sum of all players participating in the different phases of the program. However, not all of them took part in each testing phase. The battery included physical measurements (height and weight), a 4 x 10-m running test, explosive power tests (medicine ball throw and standing long jump), speed tests (a 20-m sprint from a standing position and a 20-m sprint with a flying start), and a slalom dribbling test. Comparisons between those players eventually selected to the Junior National Team 2-3 years later with those not selected demonstrated that only the skill test served as a good indicator. In all other measurements, a wide overlap could be seen between the results of the selected and nonselected players. It is suggested that future studies investigate the usefulness of tests reflecting more specific physical ability and cognitive characteristics.

  19. PHYSICAL AND CHEMICAL CHARACTERIZATION OF NEUROLOGICAL INJURY IN AN AVIAN MODEL OF PRIMARY GENERALIZED EPILEPSY

    OpenAIRE

    Edward Kendall; Zhao Gong; John Tuchek; André Obenaus

    2011-01-01

    Purpose This study was undertaken to determine if the epileptic chicken phenotype exhibited unique physical and chemical neurological changes. Methods Quantitative 1H-MRI/MRS measurements were performed on adult control (Rr) and epileptic (rr) chickens. The metrics included nuclear relaxation rate, diffusion rate and concentration of metabolites associated with neuronal cells. Comparisons were performed using Students t or Mann-Whitney tests according to the data distribution. Results Proton ...

  20. Procedures and reasoning for skill proficiency testing in physical education teacher education programs

    Directory of Open Access Journals (Sweden)

    Timothy Baghurst

    2015-12-01

    Full Text Available This study sought to determine how the testing of skill proficiency is being conducted in physical education teacher education (PETE programs in the USA and how fitness or skill proficiencies, as attributes of a physical educator, are perceived. Participants were 312 college PETE program coordinators who completed an online survey about skill testing in their program. The eligible respondents yielded a 52.7% total response rate. Most participants believed that skill proficiency for PETE students was important, but only 46% of programs reported testing within their program. Many participants stated it was possible for their students to graduate without demonstrating proficiency in skill technique, yet were confident their students would pass an independent skill test. Only 46.2% of respondents indicated their students needed to demonstrate proper skill technique in order to graduate, and there was no consistent method of assessment. Responses were evenly split regarding the importance of a physical educator being able to demonstrate proper skill technique or be physically fit. The lack of skill testing in programs, combined with the variation in assessment, is concerning, and the development of a standardized skill-based test may provide more rigor to this important area of teacher credibility and effectiveness.

  1. Characterization and evaluation physical properties biodegradable plastic composite from seaweed (Eucheuma cottonii)

    Science.gov (United States)

    Deni, Glar Donia; Dhaningtyas, Shalihat Afifah; Fajar, Ibnu; Sudarno

    2015-12-01

    The characterization and evaluation of biodegradable plastic composed of a mixture PVA - carrageenan - chitosan was conducted in this study. Obtained data were then compared to commercial biodegradable plastic. Characteristic of plastic was mechanical tested such as tensile - strength and elongation. Plastic degradation was studied using composting method for 7 days and 14 days. The results showed that the increase carrageenan will decrease tensile-strength and elongation plastic composite. In addition, increase carrageenan would increase the degraded plastics composite.

  2. Characterization of holding brake friction pad surface after pin-on-plate wear test

    DEFF Research Database (Denmark)

    Drago, N.; Gonzalez Madruga, D.; De Chiffre, L.

    2018-01-01

    This article concerns the metrological characterization of the surface on a holding brake friction material pin after a pin-on-plate (POP) wear test. The POP test induces the formation of surface plateaus that affect brake performances such as wear, friction, noise and heat. Three different...... materials’ surfaces have been characterized after wear from data obtained with a focus variation 3D microscope. A new surface characterization approach with plateau identification is proposed, using the number of plateau on the surface, equivalent diameter, length and breadth as measurands...

  3. An experimental test of parenting practices as a mediator of early childhood physical aggression.

    Science.gov (United States)

    Brotman, Laurie Miller; O'Neal, Colleen R; Huang, Keng-Yen; Gouley, Kathleen Kiely; Rosenfelt, Amanda; Shrout, Patrick E

    2009-03-01

    Parenting practices predict early childhood physical aggression. Preventive interventions that alter parenting practices and aggression during early childhood provide the opportunity to test causal models of early childhood psychopathology. Although there have been several informative preventive intervention studies that test mediation models in older children, no such studies have been conducted with younger children at high risk for psychopathology. Within the context of a randomized controlled trial, we examined whether changes in parenting practices mediate the effects of a family intervention on observed physical aggression among African American and Latino younger siblings of adjudicated youths. Improved parenting practices partially mediated the intervention effect on physical aggression. Improvements in harsh parenting, responsive parenting, and stimulating parenting explained a significant amount of the intervention effect on child physical aggression observed in the context of parent-child interactions. Parenting practices accounted for 38% of the intervention effect on physical aggression. There was support for the hypothesized model of the prevention of physical aggression during early childhood. Intervention benefits on parenting practices partially accounted for intervention effects on physical aggression in young high-risk children.

  4. Advanced ceramic composite for high energy resistors. Characterization of electrical and physical properties

    International Nuclear Information System (INIS)

    Farrokh, Fattahi; Navid, Tagizadegan; Naser, Tabatabaei

    2005-01-01

    Full text : There is a need to characterize and apply advanced materials to improve the performance of components used in pulse power systems. One area for innovation is the use of bulk electrically conductive ceramics for non-inductive, high energy and high power electrical resistors. Standard Ceramics, Inc. has developed a unique silicon carbide structural ceramic composite which exhibits electrical conductivity. The new conductive bulk ceramic material has a controlled microstructure, which results an improved homogeneity, making the material suitable for use as a non-inductive, high energy resistor. The new material has higher density, highee peak of temperature limit and greater physical strength compared with bulk ceramics currently used for pulsed power resistors. This paper describes characterization of the material's physical and electrical properties and relates them to improvements in low-power density, as compared to existing components would be expected and derived from specific properties such as good thermal conductivity, high strength, thermal shock resistance and high temperature capability. The bulk resistor approach that weas proposed offers high reliability through better mechanical properties and simplicity of construction

  5. Diagnostic Accuracy of 3 Physical Examination Tests in the Assessment of Hip Microinstability.

    Science.gov (United States)

    Hoppe, Daniel J; Truntzer, Jeremy N; Shapiro, Lauren M; Abrams, Geoffrey D; Safran, Marc R

    2017-11-01

    Hip microinstability is a diagnosis gaining increasing interest. Physical examination tests to identify microinstability have not been objectively investigated using intraoperative confirmation of instability as a reference standard. To determine the test characteristics and diagnostic accuracy of 3 physical examination maneuvers in the detection of hip microinstability. Cohort study (diagnosis); Level of evidence, 2. A review was conducted of 194 consecutive hip arthroscopic procedures performed by a sports medicine surgeon at a tertiary-care academic center. Physical examination findings of interest, including the abduction-hyperextension-external rotation (AB-HEER) test, the prone instability test, and the hyperextension-external rotation (HEER) test, were obtained from prospectively collected data. The reference standard was intraoperative identification of instability based on previously published objective criteria. Test characteristics, including sensitivity, specificity, positive and negative predictive values, and accuracy, were calculated for each test as well as for combinations of tests. A total of 109 patients were included in the analysis. The AB-HEER test was most accurate, with a sensitivity of 80.6% (95% CI, 70.8%-90.5%) and a specificity of 89.4% (95% CI, 80.5%-98.2%). The prone instability test had a low sensitivity (33.9%) but a very high specificity (97.9%). The HEER test performed second in both sensitivity (71.0%) and specificity (85.1%). The combination of multiple tests with positive findings did not yield significantly greater accuracy. All tests had high positive predictive values (range, 86.3%-95.5%) and moderate negative predictive values (range, 52.9%-77.8%). When all 3 tests had positive findings, there was a 95.0% (95% CI, 90.1%-99.9%) chance that the patient had microinstability. The AB-HEER test most accurately predicted hip instability, followed by the HEER test and the prone instability test. However, the high specificity of the

  6. The modified total body rotation test: a rapid, reliable assessment of physical function in older adults.

    Science.gov (United States)

    Stanziano, Damian C; Signorile, Joseph F; Mow, Sara; Davidson, Erin E; Ouslander, Joseph G; Roos, Bernard A

    2010-10-01

    To describe a quick, modified measure of total body rotation with performance rankings for elderly persons and to highlight the importance of total body rotational ability for overall physical performance. Scores were collected during the same testing session and were compared with other measures using a Pearson correlation. Community-based senior centers. One hundred forty-five participants aged 79.6±7.2 were recruited using flyers distributed at health fairs, senior centers, and lifelong learning programs. The modified total body rotation test (MTBR), the back-scratch test, the modified sit-and-reach test, the 30-second chair-stand test, the Short Physical Performance Battery, and the short version of the Continuous-Scale Physical Functional Performance Test. The MBTR significantly correlated to all standard measures of physical performance. Norms are reported for all participants, and reliability analyses were conducted using data from 18 participants. Data were divided into quintiles to create cutoffs for physical performance rankings that can be used when reporting results to the general public. Many evaluations measure isolated components of physical performance, but few examine whole body movements that allow all components necessary for independence and function to work in harmony as needed considering the task and the individual's movement strategy. The current study offers the MTBR as a quick, easy, and cost-effective evaluation method to quantify the degree of impairment or injury and the rate of improvement with treatment or training. © 2010, Copyright the Authors. Journal compilation © 2010, The American Geriatrics Society.

  7. Validity of Combining History Elements and Physical Examination Tests to Diagnose Patellofemoral Pain.

    Science.gov (United States)

    Décary, Simon; Frémont, Pierre; Pelletier, Bruno; Fallaha, Michel; Belzile, Sylvain; Martel-Pelletier, Johanne; Pelletier, Jean-Pierre; Feldman, Debbie; Sylvestre, Marie-Pierre; Vendittoli, Pascal-André; Desmeules, François

    2018-04-01

    To assess the validity of diagnostic clusters combining history elements and physical examination tests to diagnose or exclude patellofemoral pain (PFP). Prospective diagnostic study. Orthopedic outpatient clinics, family medicine clinics, and community-dwelling. Consecutive patients (N=279) consulting one of the participating orthopedic surgeons (n=3) or sport medicine physicians (n=2) for any knee complaint. Not applicable. History elements and physical examination tests were obtained by a trained physiotherapist blinded to the reference standard: a composite diagnosis including both physical examination tests and imaging results interpretation performed by an expert physician. Penalized logistic regression (least absolute shrinkage and selection operator) was used to identify history elements and physical examination tests associated with the diagnosis of PFP, and recursive partitioning was used to develop diagnostic clusters. Diagnostic accuracy measures including sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios with associated 95% confidence intervals (CIs) were calculated. Two hundred seventy-nine participants were evaluated, and 75 had a diagnosis of PFP (26.9%). Different combinations of history elements and physical examination tests including the age of participants, knee pain location, difficulty descending stairs, patellar facet palpation, and passive knee extension range of motion were associated with a diagnosis of PFP and used in clusters to accurately discriminate between individuals with PFP and individuals without PFP. Two diagnostic clusters developed to confirm the presence of PFP yielded a positive likelihood ratio of 8.7 (95% CI, 5.2-14.6) and 3 clusters to exclude PFP yielded a negative likelihood ratio of .12 (95% CI, .06-.27). Diagnostic clusters combining common history elements and physical examination tests that can accurately diagnose or exclude PFP compared to various knee

  8. Physical examination tests for the diagnosis of posterior cruciate ligament rupture: a systematic review.

    Science.gov (United States)

    Kopkow, Christian; Freiberg, Alice; Kirschner, Stephan; Seidler, Andreas; Schmitt, Jochen

    2013-11-01

    Systematic literature review. To summarize and evaluate research on the accuracy of physical examination tests for diagnosis of posterior cruciate ligament (PCL) tear. Rupture of the PCL is a severe knee injury that can lead to delayed rehabilitation, instability, or chronic knee pathologies. To our knowledge, there is currently no systematic review of studies on the diagnostic accuracy of clinical examination tests to evaluate the integrity of the PCL. A comprehensive systematic literature search was conducted in MEDLINE from 1946, Embase from 1974, and the Allied and Complementary Medicine Database from 1985 until April 30, 2012. Studies were considered eligible if they compared the results of physical examination tests performed in the context of a PCL physical examination to those of a reference standard (arthroscopy, arthrotomy, magnetic resonance imaging). Methodological quality assessment was performed by 2 independent reviewers using the revised version of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. The search strategy revealed 1307 articles, of which 11 met the inclusion criteria for this review. In these studies, 11 different physical examination tests were identified. Due to differences in study types, different patient populations, and methodological quality, meta-analysis was not indicated. Presently, most physical examination tests have not been evaluated sufficiently enough to be confident in their ability to either confirm or rule out a PCL tear. The diagnostic accuracy of physical examination tests to assess the integrity of the PCL is largely unknown. There is a strong need for further research in this area. Level of Evidence Diagnosis, level 3a.

  9. The characterization and testing of candidate immobilization forms for the disposal of plutonium

    International Nuclear Information System (INIS)

    Bakel, A. J.; Buck, E. C.; Chamberlain, D. B.; Ebbinghaus, B. B.; Fortner, J. A.; Marra, J. C.; Mcgrail, B. P.; Mertz, C. J.; Peeler, D. K.; Shaw, H. F.; Strachan, D. M.; Van Konynenburg, R. A.; Vienna, J. D.; Wolf, S. F.

    1997-01-01

    Candidate immobilization forms for the disposal of surplus weapons-useable are being tested and characterized. The goal of the testing program was to provide sufficient data that, by August 1997, an informed selection of a single immobilization form could be made so that the form development and production R and D could be more narrowly focused. Two forms have been under consideration for the past two years: glass and ceramic. In August, 1997, the Department of Energy (DOE) selected ceramic for plutonium disposition, halting further work on the glass material. In this paper, we will briefly describe these two waste forms, then describe our characterization techniques and testing methods. The analytical methods used to characterize altered and unaltered samples are the same. A full suite of microscopic techniques is used. Techniques used include optical, scanning electron, and transmission electron microscopies. For both candidate immobilization forms, the analyses are used to characterize the material for the presence of crystalline phases and amorphous material. Crystalline materials, either in the untested immobilization form or in the alteration products from testing, are characterized with respect to morphology, crystal structure, and composition. The goal of these analyses is to provide data on critical issues such as Pu and neutron absorber volubility in the immobilization form, thermal stability, potential separation of absorber and Pu, and the long-term behavior of the materials. Results from these analyses will be discussed in the presentation. Testing methods include MCC-1 tests, product consistency tests (methods A and B), unsaturated ''drip'' tests, vapor hydration tests, single-pass flow-through tests, and pressurized unsaturated flow tests. Both candidate immobilization forms have very low dissolution rates; examples of typical test results will be reported

  10. Analysis for first startup physics test for Unit 1 of Ningde Nuclear Power Plant

    International Nuclear Information System (INIS)

    Bai Chengfei; Wang Lei; Fu Xuefeng; Zhang Hong; Wang Chuang; Zhang Songwen; Li Junde

    2014-01-01

    The gadolinium is used as the burnable poison for the first cycle of Unit l of Ningde Nuclear Power Plant, and it is the first time to apply it on a commercial PWR in the world. The results of the first startup physics test are very important for evaluating the core design. This paper describes the calculation methods, codes and comparisons between the calculation values and experimental results for the first reactor startup physics test. The results showed that the calculated theoretical values are consistent with the measured values. (authors)

  11. A new model test in high energy physics in frequentist and bayesian statistical formalisms

    International Nuclear Information System (INIS)

    Kamenshchikov, A.

    2017-01-01

    The problem of a new physical model test using observed experimental data is a typical one for modern experiments in high energy physics (HEP). A solution of the problem may be provided with two alternative statistical formalisms, namely frequentist and Bayesian, which are widely spread in contemporary HEP searches. A characteristic experimental situation is modeled from general considerations, and both the approaches are utilized in order to test a new model. The results are juxtaposed, which demonstrates their consistency in this work. An effect of a systematic uncertainty treatment in the statistical analysis is also considered.

  12. Physical, Structural, Barrier, and Antifungal Characterization of Chitosan–Zein Edible Films with Added Essential Oils

    Science.gov (United States)

    Escamilla-García, Monserrat; Calderón-Domínguez, Georgina; Chanona-Pérez, Jorge J.; Mendoza-Madrigal, Angélica G.; Di Pierro, Prospero; García-Almendárez, Blanca E.; Amaro-Reyes, Aldo

    2017-01-01

    Edible films (EFs) have gained great interest due to their ability to keep foods safe, maintaining their physical and organoleptic properties for a longer time. The aim of this work was to develop EFs based on a chitosan–zein mixture with three different essential oils (EOs) added: anise, orange, and cinnamon, and to characterize them to establish the relationship between their structural and physical properties. The addition of an EO into an EF significantly affected (p film surface. The EFs presented a refractive index between 1.35 and 1.55, and thus are classified as transparent. The physical properties of EFs with an added EO were improved, and films that incorporated the anise EO showed significantly lower water vapor permeability (1.2 ± 0.1 g mm h−1 m−2 kPa−1) and high hardness (104.3 ± 3.22 MPa). EFs with an added EO were able to inhibit the growth of Penicillium sp. and Rhizopus sp. to a larger extent than without an EO. Films’ structural changes were the result of chemical interactions among amino acid side chains from zein, glucosamine from chitosan, and cinnamaldehyde, anethole, or limonene from the EOs as detected by a Raman analysis. The incorporation of an EO in the EFs’ formulation could represent an alternative use as coatings to enhance the shelf life of food products. PMID:29117148

  13. Physical, Structural, Barrier, and Antifungal Characterization of Chitosan-Zein Edible Films with Added Essential Oils.

    Science.gov (United States)

    Escamilla-García, Monserrat; Calderón-Domínguez, Georgina; Chanona-Pérez, Jorge J; Mendoza-Madrigal, Angélica G; Di Pierro, Prospero; García-Almendárez, Blanca E; Amaro-Reyes, Aldo; Regalado-González, Carlos

    2017-11-08

    Edible films (EFs) have gained great interest due to their ability to keep foods safe, maintaining their physical and organoleptic properties for a longer time. The aim of this work was to develop EFs based on a chitosan-zein mixture with three different essential oils (EOs) added: anise, orange, and cinnamon, and to characterize them to establish the relationship between their structural and physical properties. The addition of an EO into an EF significantly affected ( p film surface. The EFs presented a refractive index between 1.35 and 1.55, and thus are classified as transparent. The physical properties of EFs with an added EO were improved, and films that incorporated the anise EO showed significantly lower water vapor permeability (1.2 ± 0.1 g mm h -1 m -2 kPa -1 ) and high hardness (104.3 ± 3.22 MPa). EFs with an added EO were able to inhibit the growth of Penicillium sp. and Rhizopus sp. to a larger extent than without an EO. Films' structural changes were the result of chemical interactions among amino acid side chains from zein, glucosamine from chitosan, and cinnamaldehyde, anethole, or limonene from the EOs as detected by a Raman analysis. The incorporation of an EO in the EFs' formulation could represent an alternative use as coatings to enhance the shelf life of food products.

  14. Physical, Structural, Barrier, and Antifungal Characterization of Chitosan–Zein Edible Films with Added Essential Oils

    Directory of Open Access Journals (Sweden)

    Monserrat Escamilla-García

    2017-11-01

    Full Text Available Edible films (EFs have gained great interest due to their ability to keep foods safe, maintaining their physical and organoleptic properties for a longer time. The aim of this work was to develop EFs based on a chitosan–zein mixture with three different essential oils (EOs added: anise, orange, and cinnamon, and to characterize them to establish the relationship between their structural and physical properties. The addition of an EO into an EF significantly affected (p < 0.05 the a* (redness/greenness and b* (yellowness/blueness values of the film surface. The EFs presented a refractive index between 1.35 and 1.55, and thus are classified as transparent. The physical properties of EFs with an added EO were improved, and films that incorporated the anise EO showed significantly lower water vapor permeability (1.2 ± 0.1 g mm h−1 m−2 kPa−1 and high hardness (104.3 ± 3.22 MPa. EFs with an added EO were able to inhibit the growth of Penicillium sp. and Rhizopus sp. to a larger extent than without an EO. Films’ structural changes were the result of chemical interactions among amino acid side chains from zein, glucosamine from chitosan, and cinnamaldehyde, anethole, or limonene from the EOs as detected by a Raman analysis. The incorporation of an EO in the EFs’ formulation could represent an alternative use as coatings to enhance the shelf life of food products.

  15. CHEMICAL AND PHYSICAL CHARACTERIZATION OF COLLAPSING LOW-MASS PRESTELLAR DENSE CORES

    International Nuclear Information System (INIS)

    Hincelin, U.; Commerçon, B.; Wakelam, V.; Hersant, F.; Guilloteau, S.; Herbst, E.

    2016-01-01

    The first hydrostatic core, also called the first Larson core, is one of the first steps in low-mass star formation as predicted by theory. With recent and future high-performance telescopes, the details of these first phases are becoming accessible, and observations may confirm theory and even present new challenges for theoreticians. In this context, from a theoretical point of view, we study the chemical and physical evolution of the collapse of prestellar cores until the formation of the first Larson core, in order to better characterize this early phase in the star formation process. We couple a state-of-the-art hydrodynamical model with full gas-grain chemistry, using different assumptions for the magnetic field strength and orientation. We extract the different components of each collapsing core (i.e., the central core, the outflow, the disk, the pseudodisk, and the envelope) to highlight their specific physical and chemical characteristics. Each component often presents a specific physical history, as well as a specific chemical evolution. From some species, the components can clearly be differentiated. The different core models can also be chemically differentiated. Our simulation suggests that some chemical species act as tracers of the different components of a collapsing prestellar dense core, and as tracers of the magnetic field characteristics of the core. From this result, we pinpoint promising key chemical species to be observed.

  16. Characterizing exposure to physical risk factors among reforestation hand planters in the Southeastern United States.

    Science.gov (United States)

    Granzow, Robert F; Schall, Mark C; Smidt, Mathew F; Chen, Howard; Fethke, Nathan B; Huangfu, Rong

    2018-01-01

    Low back and neck/shoulder pain are commonly reported among reforestation hand planters. While some studies have documented the intensive cardiovascular demands of hand planting, limited information is available regarding exposures to physical risk factors associated with the development of musculoskeletal disorders (MSDs) among hand planters. This study used surface electromyography (EMG) and inertial measurement units (IMUs) to characterize the muscle activation patterns, upper arm and trunk postures, movement velocities, and physical activity (PA) of fourteen Southeastern reforestation hand planters over one work shift. Results indicated that hand planters are exposed to physical risk factors such as extreme trunk postures (32.5% of time spent in ≥45° trunk flexion) and high effort muscle exertions (e.g., mean root-mean-square right upper trapezius amplitude of 54.1% reference voluntary exertion) that may place them at increased risk for developing MSDs. The findings indicate a need for continued field-based research among hand planters to identify and/or develop maximally effective interventions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. CHEMICAL AND PHYSICAL CHARACTERIZATION OF COLLAPSING LOW-MASS PRESTELLAR DENSE CORES

    Energy Technology Data Exchange (ETDEWEB)

    Hincelin, U. [Department of Chemistry, University of Virginia, Charlottesville, VA 22904 (United States); Commerçon, B. [Ecole Normale Supérieure de Lyon, CRAL, UMR 5574 du CNRS, Université Lyon I, 46 Allée d’Italie, F-69364 Lyon cedex 07 (France); Wakelam, V.; Hersant, F.; Guilloteau, S. [Univ. Bordeaux, LAB, UMR 5804, F-33270, Floirac (France); Herbst, E., E-mail: ugo.hincelin@gmail.com [Departments of Chemistry and Astronomy, University of Virginia, Charlottesville, VA 22904 (United States)

    2016-05-01

    The first hydrostatic core, also called the first Larson core, is one of the first steps in low-mass star formation as predicted by theory. With recent and future high-performance telescopes, the details of these first phases are becoming accessible, and observations may confirm theory and even present new challenges for theoreticians. In this context, from a theoretical point of view, we study the chemical and physical evolution of the collapse of prestellar cores until the formation of the first Larson core, in order to better characterize this early phase in the star formation process. We couple a state-of-the-art hydrodynamical model with full gas-grain chemistry, using different assumptions for the magnetic field strength and orientation. We extract the different components of each collapsing core (i.e., the central core, the outflow, the disk, the pseudodisk, and the envelope) to highlight their specific physical and chemical characteristics. Each component often presents a specific physical history, as well as a specific chemical evolution. From some species, the components can clearly be differentiated. The different core models can also be chemically differentiated. Our simulation suggests that some chemical species act as tracers of the different components of a collapsing prestellar dense core, and as tracers of the magnetic field characteristics of the core. From this result, we pinpoint promising key chemical species to be observed.

  18. Physical Stress Echocardiography: Prediction of Mortality and Cardiac Events in Patients with Exercise Test showing Ischemia

    Directory of Open Access Journals (Sweden)

    Ana Carla Pereira de Araujo

    2014-11-01

    Full Text Available Background: Studies have demonstrated the diagnostic accuracy and prognostic value of physical stress echocardiography in coronary artery disease. However, the prediction of mortality and major cardiac events in patients with exercise test positive for myocardial ischemia is limited. Objective: To evaluate the effectiveness of physical stress echocardiography in the prediction of mortality and major cardiac events in patients with exercise test positive for myocardial ischemia. Methods: This is a retrospective cohort in which 866 consecutive patients with exercise test positive for myocardial ischemia, and who underwent physical stress echocardiography were studied. Patients were divided into two groups: with physical stress echocardiography negative (G1 or positive (G2 for myocardial ischemia. The endpoints analyzed were all-cause mortality and major cardiac events, defined as cardiac death and non-fatal acute myocardial infarction. Results: G2 comprised 205 patients (23.7%. During the mean 85.6 ± 15.0-month follow-up, there were 26 deaths, of which six were cardiac deaths, and 25 non-fatal myocardial infarction cases. The independent predictors of mortality were: age, diabetes mellitus, and positive physical stress echocardiography (hazard ratio: 2.69; 95% confidence interval: 1.20 - 6.01; p = 0.016. The independent predictors of major cardiac events were: age, previous coronary artery disease, positive physical stress echocardiography (hazard ratio: 2.75; 95% confidence interval: 1.15 - 6.53; p = 0.022 and absence of a 10% increase in ejection fraction. All-cause mortality and the incidence of major cardiac events were significantly higher in G2 (p < 0. 001 and p = 0.001, respectively. Conclusion: Physical stress echocardiography provides additional prognostic information in patients with exercise test positive for myocardial ischemia.

  19. Production Test N-611 and N-614 emergency cooling/fog spray supply characterization tests: Final report

    International Nuclear Information System (INIS)

    Conn, K.R.; Kelly, W.S.; Zaloudek, F.R.

    1989-05-01

    The results of Production Tests N-611 and N-614 (PTN-611 and PTN-614), Emergency Cooling/Fog Spray Supply Characterization Tests are reported. These production tests consisted of 21 individual tests designed to characterize the diesel-driven pumps and piping sections in the emergency core cooling system (ECCS), the fog spray systems, and the effluent disposal systems. Production Test N-614 included demineralized water and filtered water tank drawdowns and emergency raw water tank fillups to calibrate flow measurement devices in the RWS-2 and the ECCS, and tests to establish the performance of the high-lift fog spray diesel-driven pumps. It also demonstrated operation of the low-lift diesel-driven pumps with the river flow at the minimum release rate allowed by the operating license for Priest Rapids Dam. The tank drawdown data was also used to determine loss coefficients in piping between the demineralized water storage tank and the high-lift diesel-driven pumps. Other tests provided information on the division of the low lift flow between the silo and the RWS-2, and on the performance of the low-lift diesel-driven pumps. 13 figs., 7 tabs

  20. The physical therapy profile questionnaire (PTPQ: development, validation and pilot testing

    Directory of Open Access Journals (Sweden)

    Grimmer-Somers Karen

    2011-09-01

    Full Text Available Abstract Background Country by country similarities and differences in physical therapy practice exists. Therefore, before updates in practice can be provided, such as trainings in evidence-based practice, it is necessary to identify the profile and nature of practice in a given country or setting. Following a search of the international literature, no appropriate tool was identified to collect and establish data to create the profile of physical therapy practice in the Philippines. We therefore developed, validated and pilot tested a survey instrument which would comprehensively describe the practice of physical therapy in the Philippines Findings We used a mixed methods design to answer our study aims. A focus group interview was conducted among a group of physical therapists to establish the content and contexts of items to be included in the survey instrument. Findings were amalgamated with the information from the literature on developing survey instruments/questionnaires. A survey instrument was drafted and named as the Physical Therapy Profile Questionnaire (PTPQ. The PTPQ was then validated and pilot tested to a different group of physical therapists. The final version consisted of five separate parts namely (A General information and demographics, (B Practice Profile, (C Treatment Preferences, (D Bases for clinical work and (E Bases for educational/research work. At present the PTPQ is relevant to the Philippines and could be used by any country which has a similar nature of practice with the Philippines. Conclusion The Physical Therapy Practice Questionnaire (PTPQ was shown to have good face and content validity among the Filipino physical therapists and their context of practice. It has also been found to be useful, easy to administer tool and in a format appealing to respondents. The PTPQ is expected to assist comprehensive data collection to create a profile of physical therapy practice in the Philippines.

  1. The physical therapy profile questionnaire (PTPQ): development, validation and pilot testing.

    Science.gov (United States)

    Dizon, Janine Margarita R; Grimmer-Somers, Karen; Kumar, Saravana

    2011-09-19

    Country by country similarities and differences in physical therapy practice exists. Therefore, before updates in practice can be provided, such as trainings in evidence-based practice, it is necessary to identify the profile and nature of practice in a given country or setting. Following a search of the international literature, no appropriate tool was identified to collect and establish data to create the profile of physical therapy practice in the Philippines. We therefore developed, validated and pilot tested a survey instrument which would comprehensively describe the practice of physical therapy in the Philippines We used a mixed methods design to answer our study aims. A focus group interview was conducted among a group of physical therapists to establish the content and contexts of items to be included in the survey instrument. Findings were amalgamated with the information from the literature on developing survey instruments/questionnaires. A survey instrument was drafted and named as the Physical Therapy Profile Questionnaire (PTPQ). The PTPQ was then validated and pilot tested to a different group of physical therapists.The final version consisted of five separate parts namely (A) General information and demographics, (B) Practice Profile, (C) Treatment Preferences, (D) Bases for clinical work and (E) Bases for educational/research work. At present the PTPQ is relevant to the Philippines and could be used by any country which has a similar nature of practice with the Philippines. The Physical Therapy Practice Questionnaire (PTPQ) was shown to have good face and content validity among the Filipino physical therapists and their context of practice. It has also been found to be useful, easy to administer tool and in a format appealing to respondents. The PTPQ is expected to assist comprehensive data collection to create a profile of physical therapy practice in the Philippines.

  2. Improving the exam experience: Testing test procedures in introductory physical science courses at a two-year college

    Science.gov (United States)

    Marton, F.; McCrary, M.

    2013-12-01

    Bergen Community College (BCC) is a two-year college in the New York City metropolitan area with a diverse student body and total enrollment of approximately 17,000. Most students have a gen-ed requirement of two lab science courses which employ numerous methods of assessment, including tests. Traditionally, students take tests individually and often, once they get back the graded tests, glance over the results and file the tests away. In addition to individual test-taking, we have begun using and comparing two types of procedures to see how their understanding of the material may improve in introductory-level geology and physics classes. The first procedure explored the benefit of group work to reinforce concepts, worth 20% of the overall test grade. Conceptual and algebra-based physics classes took short group tests, consisting of open-ended challenge questions, preceding their traditional, individual exam. We found the group testing significantly helped the physics students; in some cases, counting for more than 20% of their overall test grade. Because those problems were done at the beginning of the test, it helped many students reinforce their understanding of the physics concepts through intense group discussion, which allowed them to be more relaxed and confident when they did their individual problems. In geology, the students re-did the T/F, MC, and fill-in questions that they answered independently first. By consulting with their fellow students, they were able to talk over the concepts and correct their answers if they felt they were initially wrong. Overall, when the questions were re-done during the group testing, the median improvement in correct answers was 16-24%. Moreover, students generally felt either confident in their answers or, if they changed them, understood the concepts better. For the second type of test procedure, students in a geology class were able to make corrections to the T/F, MC, and fill-in questions that they got wrong. If they

  3. Testing Gravitational Physics with Space-based Gravitational-wave Observations

    Science.gov (United States)

    Baker, John G.

    2011-01-01

    Gravitational wave observations provide exceptional and unique opportunities for precision tests of gravitational physics, as predicted by general relativity (GR). Space-based gravitational wave measurements, with high signal-to-noise ratios and large numbers of observed events may provide the best-suited gravitational-wave observations for testing GR with unprecedented precision. These observations will be especially useful in testing the properties of gravitational waves and strong-field aspects of the theory which are less relevant in other observations. We review the proposed GR test based on observations of massive black hole mergers, extreme mass ratio inspirals, and galactic binary systems.

  4. Characterization of granular and polymer-embedded RDX grades: Floret tests

    NARCIS (Netherlands)

    Heijden, A.E.D.M. van der; Bouma, R.H.B.

    2016-01-01

    In an attempt to further contribute to the characterization of explosive compositions, small scale Floret tests were performed using four RDX grades, differing in product quality. A Floret test provides a measure – by indentation of a copper block – of detonation spreading or the initiability and

  5. Development of a Physical Employment Testing Battery for Infantry Soldiers: 11B Infantryman and 11C Infantryman-Indirect Fire

    Science.gov (United States)

    2015-12-01

    the Army Physical Fitness Test (APFT). This test creates a score based on the number of push-ups performed in two minutes, the number of sit-ups...signed a consent form, and completed questionnaires about their demographics and most recent Army Physical Fitness Test (APFT). Height and weight in...studies will be conducted at Ft Stewart, GA to identify simple physical fitness tests that can be used to predict performance on the task simulations

  6. BP-5 Remedial Investigation Slug-Test Characterization Results for Well 699-52-55A

    Energy Technology Data Exchange (ETDEWEB)

    Newcomer, Darrell R.

    2008-07-21

    Pacific Northwest National Laboratory conducted slug-test characterization at the final, completed BP-5 Remedial Investigation well 699-52-55A near the 200-East Area at the Hanford Site on April 22, 2008. The slug-test characterization was in support of the BP-5 Remedial Investigation. The portion of the unconfined aquifer tested is composed of sediments of the lower Ringold Formation and the underlying Elephant Mountain basalt flowtop. The basalt flowtop unit was included as part of the effective test-interval length for the slug-test analysis because the flowtop unit is hydraulically communicative with the unconfined aquifer. Estimates of hydraulic conductivity for the effective test-interval length represent composite values for the lower Ringold Formation and the underlying Elephant Mountain basalt flow top.

  7. Electrophysiological predictors of sudden cardiac death on physical exercise test in young athletes

    Science.gov (United States)

    Balykova, L. A.; Kotlyarov, A. A.; Ivyanskiy, S. A.; Shirokova, A. A.; Miheeva, K. A.; Makarov, L. M.

    2017-01-01

    The problem of sudden death of young athletes continues to be actual. Among its reasons, primary electric myocardium diseases along with organic heart troubles (cardiomyopathies, cordites, anomalies of coronary arteries) take an important place. The most frequent variant of channelopathesis long QT syndrome (LQTS). Both inherited and acquired LQTS may be the reason of sudden cardiac death during physical activity and have to be revealed prior to sports admission. LQTS diagnostics in young athletes become problematic due to secondary exercise-related QT prolongation. Physical load test may reveal myocardium electric instability and enhance LQTS diagnostics accuracy without genetic testing. The aim was to study electrophysiological parameters of myocardium repolarization and reveal the signs of electrical instability as predictors of the life-threatening arrhythmias in young athletes during physical exercise test. In conclusion, electrophysiological myocardium parameters during physical exercise test noted to be markers of electrical myocardial instability and in combination with the other Schwartz criteria, was evidenced the inherited or acquired LQTS. QTc prolongation in athletes at the peak of exercise as well as in early recovery period were noted to be additional predictor life-threatening arrhythmias and sudden cardiac death in young athletes

  8. Physical and mechanical testing of essential oil-embedded cellulose ester films

    Science.gov (United States)

    Polymer films made from cellulose esters are useful for embedding plant essential oils, either for food packaging or air freshener applications. Studies and testing were done on the physical and mechanical properties of cellulose ester-based films incorporating essential oils (EO) from lemongrass (C...

  9. Density-dependent effects on physical condition and reproduction in North American elk: an experimental test.

    Science.gov (United States)

    Kelley M. Stewart; R. Terry Bowyer; Brian L. Dick; Bruce K. Johnson; John G. Kie

    2005-01-01

    Density dependence plays a key role in life-history characteristics and population ecology of large, herbivorous mammals. We designed a manipulative experiment to test hypotheses relating effects of density-dependent mechanisms on physical condition and fecundity of North American elk (Cervus elaphus) by creating populations at low and high density...

  10. Hip joint pathology: relationship between patient history, physical tests, and arthroscopy findings in clinical practice

    NARCIS (Netherlands)

    Tijssen, M.; Cingel, R.E. van; Visser, E de; Holmich, P.; Nijhuis-Van der Sanden, M.W.G.

    2017-01-01

    The purpose of this retrospective cohort study was to (a) describe the clinical presentation of femoroacetabular impingement (FAI) and hip labral pathology; (b) describe the accuracy of patient history and physical tests for FAI and labral pathology as confirmed by hip arthroscopy. Patients (18-65

  11. Physical Education Teacher Attitudes toward Fitness Test Scale: Development and Validation

    Science.gov (United States)

    Keating, Xiaofen Deng; Silverman, Stephen

    2004-01-01

    The Physical Education Teacher Attitudes Toward Fitness Test Scale (PETAFTS) produces reliable and valid scores. There were 4 stages and 4 sets of participants in the development of the PETAFTS. First, the domains of attitude were defined and cognitive and affective components were developed, organized, and validated. In the second stage, 134…

  12. Reliability of Health-Related Physical Fitness Tests among Colombian Children and Adolescents: The FUPRECOL Study.

    Directory of Open Access Journals (Sweden)

    Robinson Ramírez-Vélez

    Full Text Available Substantial evidence indicates that youth physical fitness levels are an important marker of lifestyle and cardio-metabolic health profiles and predict future risk of chronic diseases. The reliability physical fitness tests have not been explored in Latino-American youth population. This study's aim was to examine the reliability of health-related physical fitness tests that were used in the Colombian health promotion "Fuprecol study". Participants were 229 Colombian youth (boys n = 124 and girls n = 105 aged 9 to 17.9 years old. Five components of health-related physical fitness were measured: 1 morphological component: height, weight, body mass index (BMI, waist circumference, triceps skinfold, subscapular skinfold, and body fat (% via impedance; 2 musculoskeletal component: handgrip and standing long jump test; 3 motor component: speed/agility test (4x10 m shuttle run; 4 flexibility component (hamstring and lumbar extensibility, sit-and-reach test; 5 cardiorespiratory component: 20-meter shuttle-run test (SRT to estimate maximal oxygen consumption. The tests were performed two times, 1 week apart on the same day of the week, except for the SRT which was performed only once. Intra-observer technical errors of measurement (TEMs and inter-rater (reliability were assessed in the morphological component. Reliability for the Musculoskeletal, motor and cardiorespiratory fitness components was examined using Bland-Altman tests. For the morphological component, TEMs were small and reliability was greater than 95% of all cases. For the musculoskeletal, motor, flexibility and cardiorespiratory components, we found adequate reliability patterns in terms of systematic errors (bias and random error (95% limits of agreement. When the fitness assessments were performed twice, the systematic error was nearly 0 for all tests, except for the sit and reach (mean difference: -1.03% [95% CI = -4.35% to -2.28%]. The results from this study indicate that the

  13. Reliability of Health-Related Physical Fitness Tests among Colombian Children and Adolescents: The FUPRECOL Study.

    Science.gov (United States)

    Ramírez-Vélez, Robinson; Rodrigues-Bezerra, Diogo; Correa-Bautista, Jorge Enrique; Izquierdo, Mikel; Lobelo, Felipe

    2015-01-01

    Substantial evidence indicates that youth physical fitness levels are an important marker of lifestyle and cardio-metabolic health profiles and predict future risk of chronic diseases. The reliability physical fitness tests have not been explored in Latino-American youth population. This study's aim was to examine the reliability of health-related physical fitness tests that were used in the Colombian health promotion "Fuprecol study". Participants were 229 Colombian youth (boys n = 124 and girls n = 105) aged 9 to 17.9 years old. Five components of health-related physical fitness were measured: 1) morphological component: height, weight, body mass index (BMI), waist circumference, triceps skinfold, subscapular skinfold, and body fat (%) via impedance; 2) musculoskeletal component: handgrip and standing long jump test; 3) motor component: speed/agility test (4x10 m shuttle run); 4) flexibility component (hamstring and lumbar extensibility, sit-and-reach test); 5) cardiorespiratory component: 20-meter shuttle-run test (SRT) to estimate maximal oxygen consumption. The tests were performed two times, 1 week apart on the same day of the week, except for the SRT which was performed only once. Intra-observer technical errors of measurement (TEMs) and inter-rater (reliability) were assessed in the morphological component. Reliability for the Musculoskeletal, motor and cardiorespiratory fitness components was examined using Bland-Altman tests. For the morphological component, TEMs were small and reliability was greater than 95% of all cases. For the musculoskeletal, motor, flexibility and cardiorespiratory components, we found adequate reliability patterns in terms of systematic errors (bias) and random error (95% limits of agreement). When the fitness assessments were performed twice, the systematic error was nearly 0 for all tests, except for the sit and reach (mean difference: -1.03% [95% CI = -4.35% to -2.28%]. The results from this study indicate that the "Fuprecol

  14. Cement for oil well developed from ordinary cement: characterization physical, chemical and mineralogical

    International Nuclear Information System (INIS)

    Oliveira, D.N.S.; Neves, G. de A.; Chaves, A.C.; Mendonca, A.M.G.D.; Lima, M.S. de; Bezerra, U.T.

    2012-01-01

    This work aims to characterize a new type of cement produced from the mixture of ordinary Portland cement, which can be used as an option in the cementing of oil wells. To enable this work we used the method of lineal programming for the new cement composition, then conducted tests to characterize through particle size analysis by laser diffraction, chemical analysis by EDX, TGA, X-ray diffraction, time grip, resistance to compression. The overall result showed that the new cement had made low-C3A, takes more time to the CPP, thermal stability up to 500 ° C, the kinetics of hydration and low levels of major components consistent with the specifications of ABNT. (author)

  15. Mechanical characterization tests of the X2-Gen fuel assembly and skeleton

    International Nuclear Information System (INIS)

    Kim, Hyung Kyu; Yoon, Kyung Ho; Lee, Kang Hee; Kim, Jae Yong; Lee, Young Ho; Kang, Heung Seok

    2011-01-01

    The KNF (KEPCO Nuclear Fuel) requested mechanical characterization tests of a fuel assembly and a skeleton of the X2-Gen fuel. The tests consisted of the lateral vibration and lateral/axial stiffness, lateral/axial impact and combined deflection tests carried out by using the FAMeCT (Fuel Assembly Mechanical Characterization Tester) in KAERI. The upper and lower core plate simulators were newly designed and manufactured because the fuel geometry of the X2-Gen was different from the KSNP type fuel assembly. In addition to this, the upper carriage was also revised with the LM guide system from the previous two guide rods system. Therefore, the axial and combined deflection tests were soundly executed. Each test was repeated twice to confirm the repeatability. The discrepancy from the repetition was small enough to be neglected. The mechanical characterization tests were accredited with the KOLAS (Korea Laboratory Accreditation Scheme) standard, and the certified test reports (lateral vibration, lateral/axial bending and lateral/axial impact) and the uncertified test report (combined deflection) were issued together with the current test result report

  16. Physical and chemical characterization of borosilicate glasses containing Hanford high-level wastes

    International Nuclear Information System (INIS)

    Kupfer, M.J.; Palmer, R.A.

    1980-10-01

    Scouting studies are being performed to develop and evaluate silicate glass forms for immobilization of Hanford high-level wastes. Detailed knowledge of the physical and chemical properties of these glasses is required to assess their suitability for long-term storage or disposal. Some key properties to be considered in selecting a glass waste form include leach resistance, resistance to radiation, microstructure (includes devitrification behavior or crystallinity), homogeneity, viscosity, electrical resistivity, mechanical ruggedness, thermal expansion, thermal conductivity, density, softening point, annealing point, strain point, glass transformation temperature, and refractive index. Other properties that are important during processing of the glass include volatilization of glass and waste components, and corrosivity of the glass on melter components. Experimental procedures used to characterize silicate waste glass forms and typical properties of selected glass compositions containing simulated Hanford sludge and residual liquid wastes are presented. A discussion of the significance and use of each measured property is also presented

  17. Spatial characterization of Bessel-like beams for strong-field physics.

    Science.gov (United States)

    Summers, Adam M; Yu, Xiaoming; Wang, Xinya; Raoul, Maxime; Nelson, Josh; Todd, Daniel; Zigo, Stefan; Lei, Shuting; Trallero-Herrero, Carlos A

    2017-02-06

    We present a compact, simple design for the generation and tuning of both the spot size and effective focal length of Bessel-like beams. In particular, this setup provides an important tool for the use of Bessel-like beams with high-power, femtosecond laser systems. Using a shallow angle axicon in conjunction with a spherical lens, we show that it is possible to focus Bessel-like modes to comparable focal spot sizes to sharp axicons while maintaining a long effective focal length. The resulting focal profiles are characterized in detail using an accurate high dynamic range imaging technique. Quantitatively, we introduce a metric (R0.8) which defines the spot-size containing 80% of the total energy. Our setup overcomes the typical compromise between long working distances and small spot sizes. This is particularly relevant for strong-field physics where most experiments must operate in vacuum.

  18. Physical and microstructural characterization of clay base ceramic product produced in Icoaraci (PA, Brazil)

    International Nuclear Information System (INIS)

    Santos, N.S.S.; Mendes, J.F.; Pamplona, V.M.S.; Andrade, S.M.C.; Dias, C.G.B.T.

    2011-01-01

    The pottery currently produced in the pole ceramist Icoaraci (PA) is an artistic legacy of indigenous peoples who inhabited the Amazon region. In the pole are produced artifacts such as vases and other decorative items, and household appliances. In this work characterizations were obtained from samples of the final product (after firing), using the technique of scanning electron microscopy (SEM) analysis by Fourier transform spectrometry (FTIR), X-ray diffraction (XRD) and determining the density of the material. The objective was to evaluate the physical, microstructural and composition of the ceramics after firing. The results revealed the existence of pores and impurities, all of which can influence the quality of the final product, as well as the main elements that constitute mineralogical and chemical material. The photomicrographs showed a considerable degree of porosity, which agrees with the density results. (author)

  19. Photo-physical characterization of fluorophore Ru(bpy32+ for optical biosensing applications

    Directory of Open Access Journals (Sweden)

    E.L. Sciuto

    2015-12-01

    Full Text Available We studied absorption, emission and lifetime of the coordination compound tris(2,2′-bipyridylruthenium(II fluorophore (Ru(bpy32+ both dissolved in water solutions and dried. Lifetime measurements were carried out using a new detector, the Silicon Photomultiplier (SiPM, which is more sensitive and physically much smaller than conventional optical detectors, such as imager and scanner. Through these analyses and a morphological characterization with transmission electron microscopy, revealed its usability for sensor applications, in particular, as dye in optical DNA-chip technology, a viable alternative to the conventional CY5 fluorophore. The use of Ru(bpy32+ would solve some of the typical disadvantages related to Cy5’s application, such as self-absorption of fluorescence and photobleaching. In addition, the Ru(bpy32+ longer lifetime may play a key role in the definition of new optical DNA-chip.

  20. Physical properties and characterization of Ag doped CdS thin films

    International Nuclear Information System (INIS)

    Shah, N.A.; Nazir, A.; Mahmood, W.; Syed, W.A.A.; Butt, S.; Ali, Z.; Maqsood, A.

    2012-01-01

    Highlights: ► CdS thin films were grown. ► By ion exchange, Ag was doped. ► Physical properties were investigated. - Abstract: Thin films of cadmium sulfide with very well defined preferential orientation and relatively high absorption coefficient were fabricated by thermal evaporation technique. The research is focused to the fabrication and characterization of the compositional data of CdS thin films obtained by using X-ray diffraction, scanning electron microscope along with energy dispersive X-ray spectroscopy. The optical properties were studied by using a UV-VIS-NIR spectrophotometer. The effects of silver-doping by ion exchange process on the properties of as-deposited CdS thin films have been investigated.

  1. Physical and chemical characterization of actinides in soil from Johnston Atoll

    International Nuclear Information System (INIS)

    Wolf, S.F.; Bates, J.K.; Buck, E.C.; Dietz, N.L.; Fortner, J.A.; Brown, N.R.

    1997-01-01

    Characterization of the actinide content of a sample of contaminated coral soil from Johnston Atoll, the site of three non-nuclear destructs of nuclear warhead-carrying THOR missiles in 1962, revealed that >99% of the total actinide content is associated with discrete bomb fragments. After removal of these fragments, there was an inverse correlation between actinide content and soil particle size in particles from 43 to 0.4 μm diameter. Detailed analyses of this remaining soil revealed no discrete actinide phase in these soil particles, despite measurable actinide content. Observations indicate that exposure to the environment has caused the conversion of relatively insoluble actinide oxides to the more soluble actinyl oxides and actinyl carbonate coordinated complexes. This process has led to dissolution of actinides from discrete particles and migration to the surrounding soil surfaces, resulting in a dispersion greater than would be expected by physical transport of discrete particles alone. 26 refs., 4 figs., 1 tab

  2. Characterization of Chemical and Physical Modifications of Human Serum Albumin by Capillary Zone Electrophoresis.

    Science.gov (United States)

    Marie, Anne-Lise; Tran, Nguyet Thuy; Taverna, Myriam

    2016-01-01

    Therapeutic proteins can easily undergo chemical or physical changes during their manufacturing, purification, and storage. These modifications might change or reduce their biological activity. Therefore, it is important to have analytical methodologies that are able to reliably detect, characterize, and quantify degradation products in formulations. Capillary Zone Electrophoresis (CZE) is very well suited for the analysis of proteins due to its relatively easiness of implementation, separation efficiency, and resolving power. We describe here a CZE method that allows separating more than nine forms in therapeutic albumin, including oxidized, glycated, and truncated forms. This method uses a polyethylene oxide (PEO) coating and a buffer composed of HEPES and SDS at physiological pH. The method is reproducible (RSD < 0.5 and 4 % for migration times and peak areas, respectively) and allows quantitation of albumin forms in pharmaceutical preparations.

  3. Characterization and comparison of TiN layers deposited by different physical vapour deposition processes

    Energy Technology Data Exchange (ETDEWEB)

    Benmalek, M.; Gimenez, P. (Pechiney CRV SA, 38 - Voreppe (France)); Peyre, J.P.; Tournier, C. (CETIM, 60 - Senlis (France))

    1991-11-29

    Characterization of titanium nitride films prepared by the main physical vapour deposition processes, including ion plating, arc deposition and sputtering, was undertaken. Samples supplied by different coating manufacturers were submitted to comparative investigations using scanning electron microscopy observations, X-ray diffraction, microhardness and friction measurements. Before deposition, tool steel samples were heat treated and surface polished under identical conditions. Differences exhibited by the films in morphology, structure, hardness, adhesion and friction were related either to those existing betweeing deposition mechanisms or to the parameters of the processes. In study of the friction behaviour of an aluminium alloy-titanium nitride couple in dry conditions, the magnetron-sputtered film was found to present the best result. (orig.).

  4. Graphite nodules in fatigue-tested cast iron characterized in 2D and 3D

    DEFF Research Database (Denmark)

    Mukherjee, Krishnendu; Fæster, Søren; Hansen, Niels

    2017-01-01

    Thick-walled ductile iron casts have been studied by applying (i) cooling rate calculations by FVM, (ii) microstructural characterization by 2D SEM and 3D X-ray tomography techniques and (iii) fatigue testing of samples drawn from components cast in sand molds and metal molds. An analysis has shown...... correlations between cooling rate, structure and fatigue strengths demonstrating the benefit of 3D structural characterization to identify possible causes of premature fatigue failure of ductile cast iron....

  5. Reliability of physical functioning tests in patients with low back pain: a systematic review.

    Science.gov (United States)

    Denteneer, Lenie; Van Daele, Ulrike; Truijen, Steven; De Hertogh, Willem; Meirte, Jill; Stassijns, Gaetane

    2018-01-01

    The aim of this study was to provide a comprehensive overview of physical functioning tests in patients with low back pain (LBP) and to investigate their reliability. A systematic computerized search was finalized in four different databases on June 24, 2017: PubMed, Web of Science, Embase, and MEDLINE. Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were followed during all stages of this review. Clinical studies that investigate the reliability of physical functioning tests in patients with LBP were eligible. The methodological quality of the included studies was assessed with the use of the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) checklist. To come to final conclusions on the reliability of the identified clinical tests, the current review assessed three factors, namely, outcome assessment, methodological quality, and consistency of description. A total of 20 studies were found eligible and 38 clinical tests were identified. Good overall test-retest reliability was concluded for the extensor endurance test (intraclass correlation coefficient [ICC]=0.93-0.97), the flexor endurance test (ICC=0.90-0.97), the 5-minute walking test (ICC=0.89-0.99), the 50-ft walking test (ICC=0.76-0.96), the shuttle walk test (ICC=0.92-0.99), the sit-to-stand test (ICC=0.91-0.99), and the loaded forward reach test (ICC=0.74-0.98). For inter-rater reliability, only one test, namely, the Biering-Sörensen test (ICC=0.88-0.99), could be concluded to have an overall good inter-rater reliability. None of the identified clinical tests could be concluded to have a good intrarater reliability. Further investigation should focus on a better overall study methodology and the use of identical protocols for the description of clinical tests. The assessment of reliability is only a first step in the recommendation process for the use of clinical tests. In future research, the identified clinical tests in the

  6. AAPM Medical Physics Practice Guideline 8.a.: Linear accelerator performance tests.

    Science.gov (United States)

    Smith, Koren; Balter, Peter; Duhon, John; White, Gerald A; Vassy, David L; Miller, Robin A; Serago, Christopher F; Fairobent, Lynne A

    2017-07-01

    The purpose of this guideline is to provide a list of critical performance tests in order to assist the Qualified Medical Physicist (QMP) in establishing and maintaining a safe and effective quality assurance (QA) program. The performance tests on a linear accelerator (linac) should be selected to fit the clinical patterns of use of the accelerator and care should be given to perform tests which are relevant to detecting errors related to the specific use of the accelerator. A risk assessment was performed on tests from current task group reports on linac QA to highlight those tests that are most effective at maintaining safety and quality for the patient. Recommendations are made on the acquisition of reference or baseline data, the establishment of machine isocenter on a routine basis, basing performance tests on clinical use of the linac, working with vendors to establish QA tests and performing tests after maintenance. The recommended tests proposed in this guideline were chosen based on the results from the risk analysis and the consensus of the guideline's committee. The tests are grouped together by class of test (e.g., dosimetry, mechanical, etc.) and clinical parameter tested. Implementation notes are included for each test so that the QMP can understand the overall goal of each test. This guideline will assist the QMP in developing a comprehensive QA program for linacs in the external beam radiation therapy setting. The committee sought to prioritize tests by their implication on quality and patient safety. The QMP is ultimately responsible for implementing appropriate tests. In the spirit of the report from American Association of Physicists in Medicine Task Group 100, individual institutions are encouraged to analyze the risks involved in their own clinical practice and determine which performance tests are relevant in their own radiotherapy clinics. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on

  7. Development and Application of Diagnostic Test to Identify Students' Misconceptions of Quantum Physics

    International Nuclear Information System (INIS)

    Halim, A.A.; Meerah, T.S.; Lilia Halim

    2009-01-01

    A study on students' misconceptions on quantum physics is rarely being done, because the target audience is quite small. It is important to understand quantum physics concepts correctly especially for science students. This study was under taken to help students identify their misconceptions at the early stage. The aim of this study is to develop a diagnostic test which can access the students' misconceptions, and use the findings for the benefits of quantum physics courses. A multiple-choice Quantum Physics Diagnostic Test (QPDT), that involves concepts of light, atomic model, particle-wave dualism, wave function, and potential energy, was administered to 200 university students. The results shows that many students use the classical concepts to describe the quantum phenomenon. For example students describe light only as a wave, an electron only as a particle, and that the atomic structure is parallel to the solar system. To overcome these problems, it is suggested that lecturers spend more time in explaining the basic definitions and using analogies in quantum physics teaching. (author)

  8. PHYSICS

    CERN Multimedia

    J. D'Hondt

    The Electroweak and Top Quark Workshop (16-17th of July) A Workshop on Electroweak and Top Quark Physics, dedicated on early measurements, took place on 16th-17th July. We had more than 40 presentations at the Workshop, which was an important milestone for 2007 physics analyses in the EWK and TOP areas. The Standard Model has been tested empirically by many previous experiments. Observables which are nowadays known with high precision will play a major role for data-based CMS calibrations. A typical example is the use of the Z to monitor electron and muon reconstruction in di-lepton inclusive samples. Another example is the use of the W mass as a constraint for di-jets in the kinematic fitting of top-quark events, providing information on the jet energy scale. The predictions of the Standard Model, for what concerns proton collisions at the LHC, are accurate to a level that the production of W/Z and top-quark events can be used as a powerful tool to commission our experiment. On the other hand the measure...

  9. Preparation and characterization of physically modified glass beads used as model carriers in dry powder inhalers.

    Science.gov (United States)

    Zellnitz, Sarah; Redlinger-Pohn, Jakob Dominik; Kappl, Michael; Schroettner, Hartmuth; Urbanetz, Nora Anne

    2013-04-15

    The aim of this work is the physical modification and characterization of the surface topography of glass beads used as model carriers in dry powder inhalers (DPIs). By surface modification the contact area between drug and carrier and thereby interparticle forces may be modified. Thus the performance of DPIs that relies on interparticle interactions may be improved. Glass beads were chosen as model carriers because various prospects of physical surface modification may be applied without affecting other factors also impacting interparticle interactions like particle size and shape. To generate rough surfaces glass beads were processed mechanically by friction and impaction in a ball mill with different grinding materials that were smaller and harder with respect to the glass beads. By varying the grinding time (4 h, 8 h) and by using different grinding media (tungsten carbide, quartz) surfaces with different shades of roughness were generated. Depending on the hardness of the grinding material and the grinding time the surface roughness was more or less pronounced. Surface roughness parameters and specific surface area were determined via several complementary techniques in order to get an enhanced understanding of the impact of the modifying procedure on the surface properties of the glass beads. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Fabrication and characterization of a cell electrostimulator device combining physical vapor deposition and laser ablation

    Science.gov (United States)

    Aragón, Angel L.; Pérez, Eliseo; Pazos, Antonio; Bao-Varela, Carmen; Nieto, Daniel

    2017-08-01

    In this work we present the process of fabrication and optimization of a prototype of a cell electrostimulator device for medical application combining physical vapor deposition and laser ablation. The fabrication of the first prototype begins with a deposition of a thin layer of 200 nm of aluminium on a borosilicate glass substrate using physical vapor deposition (PVD). In the second stage the geometry design of the electrostimulator is made in a CAD-like software available in a Nd:YVO4 Rofin Power line 20E, operating at the fundamental wavelength of 1064 nm and 20 ns pulse width. Choosing the proper laser parameters the negative of the electrostimulator desing is ablated. After that the glass is assembled between two polycarbonate sheets and a thick sheet of polydimethylsiloxane (PDMS). The PDMS sheet has a round hole in where cells are placed. There is also included a thin soda-lime silicate glass (100 μm) between the electrostimulator and the PMDS to prevent the cells for being in contact with the electric circuit. In order to control the electrical signal applied to the electrostimulator is used a digital I/O device from National Instruments (USB-6501) which provides 5 V at the output monitored by a software programmed in LabVIEW. Finally, the optical and electrical characterization of the cell electrostimulator device is presented.

  11. Characterizing New Physics with Polarized Beams at High-Energy Hadron Colliders

    CERN Document Server

    Fuks, Benjamin; Rojo, Juan; Schienbein, Ingo

    2014-01-01

    The TeV energy region is currently being explored by both the ATLAS and CMS experiments of the Large Hadron Collider and phenomena beyond the Standard Model are extensively searched for. Large fractions of the parameter space of many models have already been excluded, and the ranges covered by the searches will certainly be increased by the upcoming energy and luminosity upgrades. If new physics has to be discovered in the forthcoming years, the ultimate goal of the high-energy physics program will consist of fully characterizing the newly-discovered degrees of freedom in terms of properties such as their masses, spins and couplings. The scope of this paper is to show how the availability of polarized beams at high-energy proton-proton colliders could yield a unique discriminating power between different beyond the Standard Model scenarios. We first discuss in a model-independent way how this discriminating power arises from the differences between polarized and unpolarized parton distribution functions. We t...

  12. Characterization of Physically and Chemically Separated Athabasca Asphaltenes Using Small-Angle X-ray Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Amundaraín Hurtado, Jesús Leonardo; Chodakowski, Martin; Long, Bingwen; Shaw, John M. (Alberta)

    2012-02-07

    Athabasca asphaltenes were characterized using small-angle X-ray scattering (SAXS). Two methods were used to separate asphaltenes from the Athabasca bitumen: namely, chemical separation by precipitation with n-pentane and physical separation by nanofiltration using a zirconia membrane with a 20 nm average pore size. The permeate and chemically separated samples were diluted in 1-methylnaphtalene and n-dodecane prior to SAXS measurements. The temperature and asphaltene concentration ranges were 50-310 C and 1-10.4 wt %, respectively. Model-independent analysis of SAXS data provided the radius of gyration and the scattering coefficients. Model-dependent fits provided size distributions for asphaltenes assuming that they are dense and spherical. Model-independent analysis for physically and chemically separated asphaltenes showed significant differences in nominal size and structure, and the temperature dependence of structural properties. The results challenge the merits of using chemically separated asphaltene properties as a basis for asphaltene property prediction in hydrocarbon resources. While the residuals for model-dependent fits are small, the results are inconsistent with the structural parameters obtained from model-independent analysis.

  13. Drying kinetics and physical and chemical characterization of white-fleshed ‘pitaya’ peels

    Directory of Open Access Journals (Sweden)

    Francislaine S. dos Santos

    Full Text Available ABSTRACT The objective of this work was to obtain the drying kinetic curves of white-fleshed ‘pitaya’ peels and characterize the obtained powder regarding physical and chemical parameters. Different mathematical models were fitted to the experimental data of drying kinetics, considering the coefficient of determination (R2, mean square deviation (MSD and residual distribution as fit criteria. The peels had an initial moisture content of 93.38% (w.b. and final moisture contents of 5.39% at temperature of 50 °C, 5.27% at 60 °C and 4.40% at 70 °C. After drying, the peels were disintegrated to obtain the powders and characterized for moisture content, reducing sugars, total titratable acidity, ascorbic acid, betacyanins, betaxanthins, water activity and color, in order to evaluate the influence of temperature on the quality of powders. The Page model was the one that best fitted to the experimental data, presenting coefficient of determination higher than 0.998, mean square deviation lower than 0.02 and random distribution of residuals. Increment in drying air temperature promoted increase of pH, ascorbic acid, luminosity and yellowness, and reduction of moisture content, reducing sugars, acidity, betacyanins, betaxanthins, water activity and redness. Considering the retention of betalains, the drying temperature of 50 °C is the most suitable for the production and use of ‘pitaya’ peel powder.

  14. Preparation, physical characterization, and stability of Ferrous-Chitosan microcapsules using different iron sources

    Science.gov (United States)

    Handayani, Noer Abyor; Luthfansyah, M.; Krisanti, Elsa; Kartohardjono, Sutrasno; Mulia, Kamarza

    2017-11-01

    Dietary modification, supplementation and food fortification are common strategies to alleviate iron deficiencies. Fortification of food is an effective long-term approach to improve iron status of populations. Fortification by adding iron directly to food will cause sensory problems and decrease its bioavailability. The purpose of iron encapsulation is: (1) to improve iron bioavailability, by preventing oxidation and contact with inhibitors and competitors; and (2) to disguise the rancid aroma and flavor of iron. A microcapsule formulation of two suitable iron compounds (iron II fumarate and iron II gluconate) using chitosan as a biodegradable polymer will be very important. Freeze dryer was also used for completing the iron microencapsulation process. The main objective of the present study was to prepare and characterize the iron-chitosan microcapsules. Physical characterization, i.e. encapsulation efficiency, iron loading capacity, and SEM, were also discussed in this paper. The stability of microencapsulated iron under simulated gastrointestinal conditions was also investigated, as well. Both iron sources were highly encapsulated, ranging from 71.5% to 98.5%. Furthermore, the highest ferrous fumarate and ferrous gluconate loaded were 1.9% and 4.8%, respectively. About 1.04% to 9.17% and 45.17% to 75.19% of Fe II and total Fe, were released in simulated gastric fluid for two hours and in simulated intestinal fluid for six hours, respectively.

  15. Development and validation of a musculoskeletal physical examination decision-making test for medical students.

    Science.gov (United States)

    Bishop, Julie Y; Awan, Hisham M; Rowley, David M; Nagel, Rollin W

    2013-01-01

    Despite a renewed emphasis among educators, musculoskeletal education is still lacking in medical school and residency training programs. We created a musculoskeletal multiple-choice physical examination decision-making test to assess competency and physical examination knowledge of our trainees. We developed a 20-question test in musculoskeletal physical examination decision-making test with content that most medical students and orthopedic residents should know. All questions were reviewed by ratings of US orthopedic chairmen. It was administered to postgraduate year 2 to 5 orthopedic residents and 2 groups of medical students: 1 group immediately after their 3-week musculoskeletal course and the other 1 year after the musculoskeletal course completion. We hypothesized that residents would score highest, medical students 1 year post-musculoskeletal training lowest, and students immediately post-musculoskeletal training midrange. We administered an established cognitive knowledge test to compare student knowledge base as we expected the scores to correlate. Academic medical center in the Midwestern United States. Orthopedic residents, chairmen, and medical students. Fifty-four orthopedic chairmen (54 of 110 or 49%) responded to our survey, rating a mean overall question importance of 7.12 (0 = Not Important; 5 = Important; 10 = Very Important). Mean physical examination decision-making scores were 89% for residents, 77% for immediate post-musculoskeletal trained medical students, and 59% 1 year post-musculoskeletal trained medical students (F = 42.07, pphysical examination decision-making test was found to be internally consistent (Kuder-Richardson Formula 20 = 0.69). The musculoskeletal cognitive knowledge test was 78% for immediate post-musculoskeletal trained students and 71% for the 1 year post-musculoskeletal trained students. The student physical examination and cognitive knowledge scores were correlated (r = 0.54, pphysical examination decision-making test

  16. Characterization and Performance Testing of Natural Gas Compressors for Residential and Commercial Applications

    Science.gov (United States)

    Zhang, Xinye; Groll, Eckhard A.; Bethel, Dylan

    2017-08-01

    Relatively little information is available in the literature with respect to the performance of compressors used during the dynamic charging process of a tank. Therefore, work presented in this paper shows the measurement results of performance testing of a natural gas compressor and analyses the compressor characterization based on the experimental data. Initial tests were conducted using air and carbon dioxide given the thermodynamic similarities between these fluids and natural gas. Finally, a new test stand was specifically designed and built for compressor dynamic testing using pipeline natural gas (NG) and the compressor reliability has been evaluated inside an explosion-proof engine test cell. Reliability tests at standard operating conditions monitored the performance consistency of the compressors over the testing period and the testing consisted of a series of tank charges aimed at evaluating the maximum operating temperature as well as the mass flow rate in the system.

  17. Minimal hepatic encephalopathy characterized by parallel use of the continuous reaction time and portosystemic encephalopathy tests

    DEFF Research Database (Denmark)

    Lauridsen, M M; Schaffalitzky de Muckadell, O B; Vilstrup, H

    2015-01-01

    based vs. paper and pencil). To compare results of the Continuous Reaction time (CRT) and the Portosystemic Encephalopathy (PSE) tests in a large unselected cohort of cirrhosis patients without clinically detectable brain impairment and to clinically characterize the patients according to their test...... results. The CRT method is a 10-minute computerized test of a patient's motor reaction time stability (CRTindex) to 150 auditory stimuli. The PSE test is a 20-minute paper-pencil test evaluating psychomotor speed. Both tests were performed at the same occasion in 129 patients. Both tests were normal......Minimal hepatic encephalopathy (MHE) is a frequent complication to liver cirrhosis that causes poor quality of life, a great burden to caregivers, and can be treated. For diagnosis and grading the international guidelines recommend the use of psychometric tests of different modalities (computer...

  18. The influence of neutron and γ-radiation of physical fitness of rats in swimming test

    International Nuclear Information System (INIS)

    Shmajda, V.

    1991-01-01

    Three groups of adult male Wistar rats were exposed to neutrons (a single dose of 2 Gy) and γ-radiation (a continuous dose of 6 Gy delivered within 10.5 days) and a combination of both types of radiation. The physical fitness of irradiated and control rats was measured using a forced swimming test in the course and after the termination of the irradiation. A marked decrease in the physical fitness of all irradiated animals was followed by its normalization 3 weeks after irradiation

  19. Benchmark physics tests in the metallic-fuelled assembly ZPPR-15

    International Nuclear Information System (INIS)

    McFarlane, H.F.; Brumbach, S.B.; Carpenter, S.G.; Collins, P.J.

    1987-01-01

    Results of the first benchmark physics tests of a metallic-fueled, demonstration-size, liquid metal reactor are reported. A simple, two-zone, cylindrical conventional assembly was built with three distinctly different compositions to represent the stages of the Integral Fast Reactor fuel cycle. Experiments included criticality, control, power distribution, reaction rate ratios, reactivity coefficients, shielding, kinetics and spectrum. Analysis was done with 3-D nodal diffusion calculations and ENDFIB-V.2 cross sections. Predictions of the ZPPR-15 reactor physics parameters agreed sufficiently well with the measured values to justify confidence in design analyses for metallic-fueled LMRs

  20. The Physical and Cognitive Performance Test for Residents in Assisted Living Facilities.

    Science.gov (United States)

    Bowen, Mary Elizabeth; Rowe, Meredeth; Ersek, Mary; Ibrahim, Said; Shea, Judy A

    2017-07-01

    To develop and evaluate the psychometric properties of a new performance-based instrument (Physical and Cognitive Performance Test for Assisted Living Facilities (PCPT ALF)) designed to assess the physical and cognitive skills associated with performance of activities of daily living (ADLs) and instrumental activities of daily living (IADLs). There were three stages in this study: development of instrument items and validity testing, a feasibility pilot study, and a cross-sectional trial to establish construct and criterion validity and reliability. One 116-bed assisted living facility (ALF). After a pilot test with 10 residents, a cross-sectional trial was conducted with 55 additional residents. The Barthel Index and Functional Independence Measure were used to estimate criterion validity. Construct validity was examined using exploratory factor analyses (EFAs). Disattenuated correlations between the PCPT ALF and other tools were all greater than 0.72, supporting criterion validity. Internal consistency (physical ability, α = 0.95; cognitive support, α = 0.92) and 1-week test-retest reliability (PCPT ALF, P = .93) were high, as was interrater reliability (IRR) (physical ability, 0.99; cognitive support, 1.00). In two EFAs, a one-factor solution accounted for 64.1% of the variance for the physical ability subscale and 63.5% of the variance for the cognitive support subscale. The findings provide early evidence of the PCPT ALF's validity and reliability. If confirmed, this study's findings may be used in future work to assess the success of interventions to prevent or slow decline in the skills associated with ADL and IADL performance in ALFs. © 2017, Copyright the Authors Journal compilation © 2017, The American Geriatrics Society.

  1. Conceptual Design and Requirements for Characterization and Field Test Boreholes: Deep Borehole Field Test

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlman, Kristopher L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brady, Patrick Vane [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); MacKinnon, Robert J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Heath, Jason E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Herrick, Courtney G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jensen, Richard P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Rigali, Mark J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hadgu, Teklu [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sevougian, S. David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Birkholzer, Jens [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Freifeld, Barry M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Daley, Tom [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-09-24

    Deep Borehole Disposal (DBD) of high-level radioactive wastes has been considered an option for geological isolation for many years (Hess et al. 1957). Recent advances in drilling technology have decreased costs and increased reliability for large-diameter (i.e., ≥50 cm [19.7”]) boreholes to depths of several kilometers (Beswick 2008; Beswick et al. 2014). These advances have therefore also increased the feasibility of the DBD concept (Brady et al. 2009; Cornwall 2015), and the current field test, introduced herein, is a demonstration of the DBD concept and these advances.

  2. Physical property characterization of a damage zone in granitic rock - Implications for geothermal reservoir properties

    Science.gov (United States)

    Wenning, Quinn; Madonna, Claudio; Amann, Florian; Gischig, Valentin; Burg, Jean-Pierre

    2016-04-01

    Geothermal energy offers a viable alternative to mitigate greenhouse gas emitting energy production. A tradeoff between less expensive drilling costs and increased permeability at shallow depths versus increased heat production at deeper depths stipulates the economic energy potential of a given reservoir. From a geological perspective, successful retrieval of geothermal energy from the subsurface requires sufficient knowledge of the structural and stratigraphic relationship of the target formations, which govern the thermal conditions, physical properties, and fluid flow properties of reservoir rocks. In Switzerland, deep basement rocks (~5 km) with fluid conducting damage zones and enhanced fractured systems stimulated by hydraulic shearing are seen as a potential geothermal reservoir system. Damage zones, both natural and induced, provide permeability enhancement that is especially important for creating fluid conductivity where the matrix permeability is low. This study concentrates on characterizing the elastic and transport properties entering into a natural damage zone penetrated by a borehole at the Grimsel underground research laboratory. The borehole drilled from a cavern at 480 m below ground surface penetrates approximately 20 m of mostly intact Grimsel granodiorite before entering the first phyllosilicate-rich shear zone (~0.2 m thick). The borehole intersects a second shear zone at approximately 23.8m. Between the two shear zones the Grimsel granodiorite is heavily fractured. The minimum principle stress magnitude from in-situ measurements decreases along the borehole into the first shear zone. Two mutually perpendicular core samples of Grimsel granodiorite were taken every 0.1 m from 19.5 to 20.1 m to characterize the physical properties and anisotropy changes as a gradient away from the damage zone. Measurements of ultrasonic compressional (Vp) and shear (Vs) velocities at 1 MHz frequency are conducted at room temperature and hydrostatic pressures

  3. Physical characterization of a watershed through GIS: a study in the Schmidt stream, Brazil

    Directory of Open Access Journals (Sweden)

    D. R. Reis

    Full Text Available Remote sensing and geoprocessing are essential tools for obtaining and maintaining records of human actions on space over the course of time; these tools offer the basis for diagnoses of land use, environmental interference and local development. The Schmidt stream watershed, located in the Sinos River basin, in southern Brazil, has an environmental situation similar to that of the majority of small streams draining rural and urban areas in southern Brazil: agricultural and urbanization practices do not recognize the riparian area and there is removal of original vegetation, disregarding the suitability of land use; removal of wetlands; intensive water use for various activities; and lack of control and monitoring in the discharge of wastewater, among other factors, deteriorate the quality of this important environment.This article aims to achieve a physical characterization of the Schmidt stream watershed (Sinos river basin identifying elements such as land use and occupation, soil science, geology, climatology, extent and location of watershed, among others, so as to serve as the basis for a tool that helps in the integrated environmental management of watersheds. By applying geographic information system - GIS to the process of obtaining maps of land use and occupation, pedologicaland geological, and using climatological data from the Campo Bom meteorological station, field visit, review of literature and journals, and publicly available data, the physical characterization of the Schmidt stream watershed was performed, with a view to the integrated environmental management of this watershed. Out of the total area of the Schmidt stream watershed (23.92 km2, in terms of geology, it was observed that 23.7% consist of colluvial deposits, 22.6% consist of grass facies, and 53.7% consist of Botucatu formation. Major soil types of the watershed: 97.4% Argisols and only 2.6% Planosols. Land use and occupation is characterized by wetland (0.5%, Native

  4. Integrated use of soil physical and water isotope methods for ecohydrological characterization of desertified areas

    Science.gov (United States)

    Külls, Christoph; Nunes, Alice; Köbel-Batista, Melanie; Branquinho, Cristina; Bianconi, Nadja; Costantini, Eduardo

    2014-05-01

    Measures for monitoring desertification and soil degradation require a thorough understanding of soil physical properties and of the water balance in order to guide restoration efforts (Costantini et al. 2009). It is hypothesized that long term restoration success on degraded land depends on a series of interacting factors such as exposition, soil type, soil hydrology including lateral flow on hill-slope catenae. Recently, new soil water isotope measurement techniques have been developed (Garvelmann et al. 2012) that provide much faster and reliable stable water isotope profiles in soils. This technique yield information on groundwater recharge, soil water balance and on the origin of water available for plants, which in combination with conservative chemical tracers (chloride) can be validated. A multidisciplinary study including ecologists, soil physicists and hydrologists of the COST Action Desert Restoration Hub was carried out on four semi-arid sites in Portugal. A comparative characterization of soil physical parameters, soil water isotope and chloride profiles was performed in order to estimate pedoclimate, soil aridity, soil water balance and groundwater recharge. In combination with soil physical data a comprehensive and cross-validated characterization of pedoclimate and soil aridity was obtained. These indicators were then integrated and related to plant cover. The long-term rainfall of the four sites ranges from 512 to 638 mm, whereas air temperature is from 15.8 to 17.0°C. The De Martonne index of aridity spans from 19.3 to 24.6, pointing to semiarid to moderately arid climatic conditions. The long-term average number of days when the first 0.50 m of soil is dry ranges from 110 to 134, while the mean annual soil temperature at 0.50 m spans from 15.8 and 19.1°C. The studied profiles show different hydrological characteristics, in particular, the estimated hydraulic conductivity ranges from 0.1-1 to 10-100 µm/s. Three out of four profiles show a

  5. Characterization of the aspects of osteoprogenitor cell interactions with physical tetracalcium phosphate anchorage on titanium implant surfaces

    International Nuclear Information System (INIS)

    Ko, Chia-Ling; Chang, Ya-Yuan; Liou, Cian-Hua; Chen, Wen-Cheng

    2015-01-01

    Well-designed implants are used not only to modify the geometry of the implant but also to change the chemical properties of its surfaces. The present study aims to assess the biofunctional effects of tetracalcium phosphate (TTCP) particles as a physical anchor on the implant surface derived through sandblasting. The characteristics of the surface, cell viability, and alkaline phosphatase (ALP) activity toward osteoprogenitor cells (D1) were obtained. D1 cells were cultured on a plain surface that underwent sandblasting and acid etching (SLA) (control SLA group) and on different SLA surfaces with different anchoring TTCP rates (new test groups, M and H). The mean anchoring rates were 57% (M) and 74% (H), and the anchored thickness was estimated to range from 12.6 μm to 18.3 μm. Compared with the control SLA surface on Ti substrate, the new test groups with different TTCP anchoring rates (M and H) failed to improve cell proliferation significantly but had a well-differentiated D1 cell phenotype that enhanced ALP expression in the early stage of cell cultures, specifically, at day 7. Results suggest that the SLA surface with anchored TTCP can accelerate progenitor bone cell mineralization. This study shows the potential clinical application of the constructed geometry in TTCP anchorage on Ti for dental implant surface modification. - Highlights: • TTCP (tetracalcium phosphate) as a physical anchorage on implant is characterized. • Theoretical values of anchored thickness and capping areas were estimated. • TTCP anchored by sandblasting can accelerate progenitor bone cell mineralization. • TTCP anchored on SLA (sandblasting and acid etching) surface is a promising method

  6. Characterization of the aspects of osteoprogenitor cell interactions with physical tetracalcium phosphate anchorage on titanium implant surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Chia-Ling [Advanced Medical Devices and Composites Laboratory, Department of Fiber and Composite Materials, Feng Chia University, Taichung 40724, Taiwan (China); Dental Medical Devices and Materials Research Center, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung 807, Taiwan (China); Chang, Ya-Yuan; Liou, Cian-Hua [Alliance Global Technology Co., Ltd., Kaohsiung Medical Device Special Zone in Southern Taiwan Science Park, Kaohsiung 82151, Taiwan (China); Chen, Wen-Cheng, E-mail: wencchen@fcu.edu.tw [Advanced Medical Devices and Composites Laboratory, Department of Fiber and Composite Materials, Feng Chia University, Taichung 40724, Taiwan (China)

    2015-04-01

    Well-designed implants are used not only to modify the geometry of the implant but also to change the chemical properties of its surfaces. The present study aims to assess the biofunctional effects of tetracalcium phosphate (TTCP) particles as a physical anchor on the implant surface derived through sandblasting. The characteristics of the surface, cell viability, and alkaline phosphatase (ALP) activity toward osteoprogenitor cells (D1) were obtained. D1 cells were cultured on a plain surface that underwent sandblasting and acid etching (SLA) (control SLA group) and on different SLA surfaces with different anchoring TTCP rates (new test groups, M and H). The mean anchoring rates were 57% (M) and 74% (H), and the anchored thickness was estimated to range from 12.6 μm to 18.3 μm. Compared with the control SLA surface on Ti substrate, the new test groups with different TTCP anchoring rates (M and H) failed to improve cell proliferation significantly but had a well-differentiated D1 cell phenotype that enhanced ALP expression in the early stage of cell cultures, specifically, at day 7. Results suggest that the SLA surface with anchored TTCP can accelerate progenitor bone cell mineralization. This study shows the potential clinical application of the constructed geometry in TTCP anchorage on Ti for dental implant surface modification. - Highlights: • TTCP (tetracalcium phosphate) as a physical anchorage on implant is characterized. • Theoretical values of anchored thickness and capping areas were estimated. • TTCP anchored by sandblasting can accelerate progenitor bone cell mineralization. • TTCP anchored on SLA (sandblasting and acid etching) surface is a promising method.

  7. Verifying Digital Components of Physical Systems: Experimental Evaluation of Test Quality

    Science.gov (United States)

    Laputenko, A. V.; López, J. E.; Yevtushenko, N. V.

    2018-03-01

    This paper continues the study of high quality test derivation for verifying digital components which are used in various physical systems; those are sensors, data transfer components, etc. We have used logic circuits b01-b010 of the package of ITC'99 benchmarks (Second Release) for experimental evaluation which as stated before, describe digital components of physical systems designed for various applications. Test sequences are derived for detecting the most known faults of the reference logic circuit using three different approaches to test derivation. Three widely used fault types such as stuck-at-faults, bridges, and faults which slightly modify the behavior of one gate are considered as possible faults of the reference behavior. The most interesting test sequences are short test sequences that can provide appropriate guarantees after testing, and thus, we experimentally study various approaches to the derivation of the so-called complete test suites which detect all fault types. In the first series of experiments, we compare two approaches for deriving complete test suites. In the first approach, a shortest test sequence is derived for testing each fault. In the second approach, a test sequence is pseudo-randomly generated by the use of an appropriate software for logic synthesis and verification (ABC system in our study) and thus, can be longer. However, after deleting sequences detecting the same set of faults, a test suite returned by the second approach is shorter. The latter underlines the fact that in many cases it is useless to spend `time and efforts' for deriving a shortest distinguishing sequence; it is better to use the test minimization afterwards. The performed experiments also show that the use of only randomly generated test sequences is not very efficient since such sequences do not detect all the faults of any type. After reaching the fault coverage around 70%, saturation is observed, and the fault coverage cannot be increased anymore. For

  8. Beam Test Studies of 3D Pixel Sensors Irradiated Non-Uniformly for the ATLAS Forward Physics Detector

    CERN Document Server

    Grinstein, S; Boscardin, M; Christophersen, M; Da Via, C; Betta, G -F Dalla; Darbo, G; Fadeyev, V; Fleta, C; Gemme, C; Grenier, P; Jimenez, A; Lopez, I; Micelli, A; Nelist, C; Parker, S; Pellegrini, G; Phlips, B; Pohl, D L; Sadrozinski, H F -W; Sicho, P; Tsiskaridze, S

    2013-01-01

    Pixel detectors with cylindrical electrodes that penetrate the silicon substrate (so called 3D detectors) offer advantages over standard planar sensors in terms of radiation hardness, since the electrode distance is decoupled from the bulk thickness. In recent years significant progress has been made in the development of 3D sensors, which culminated in the sensor production for the ATLAS Insertable B-Layer (IBL) upgrade carried out at CNM (Barcelona, Spain) and FBK (Trento, Italy). Based on this success, the ATLAS Forward Physics (AFP) experiment has selected the 3D pixel sensor technology for the tracking detector. The AFP project presents a new challenge due to the need for a reduced dead area with respect to IBL, and the in-homogeneous nature of the radiation dose distribution in the sensor. Electrical characterization of the first AFP prototypes and beam test studies of 3D pixel devices irradiated non-uniformly are presented in this paper.

  9. Evaluation of spacer grid spring characteristics by means of physical tests and numerical simulation

    Energy Technology Data Exchange (ETDEWEB)

    Schettino, Carlos Frederico Mattos, E-mail: carlosschettino@inb.gov.br [Industrias Nucleares do Brasil (INB), Resende, RJ (Brazil)

    2017-11-01

    Among all fuel assemblies' components, the spacer grids play an important structural role during the energy generation process, mainly due for its primary functional requirement, that is, to provide fuel rod support. The present work aims to evaluate the spring characteristics of a specific spacer grid design used in a PWR fuel assembly type 16 x 16. These spring characteristics comprises the load versus deflection capability and its spring rate, which are very important, and also mandatory, to be correctly established in order to preclude spacer grid spring and fuel rod cladding fretting during operation, as well as prevent an excessive fuel rod buckling. This study includes physical tests and numerical simulation. The tests were performed on an adapted load cell mechanical device, using as a specimen a single strap of the spacer grid. Three numerical models were prepared using the Finite Element Method, with the support of the commercial code ANSYS. One model was built to validate the simulation according to the performed physical test, the others were built inserting a gradient of temperature (Beginning Of Life hot condition) and to evaluate the spacer grid spring characteristics in End Of Life condition. The obtained results from physical test and numerical model have shown a good agreement between them, therefore validating the simulation. The obtained results from numerical models make available information regarding the spacer grid design purpose, such as the behavior of the fuel rod cladding support during operation. Therewith, these evaluations could be useful to improve the spacer grid design. (author)

  10. Physical startup tests for VVER-1200 of Novovoronezh NPP. Advanced technique and some results

    Energy Technology Data Exchange (ETDEWEB)

    Afanasiev, Dmitry A.; Kraynov, Yury A.; Pinegin, Anatoly A.; Tsyganov, Sergey V. [National Research Centre, Moscow (Russian Federation). Kurchatov Inst.

    2017-09-15

    The intention of the startup physics tests was to confirm design characteristics of the core loading and their compliance with safety analysis preconditions. The program of startup tests for the leading unit is usually composed in such a way that is is possible to study as much neutron-physical characteristics as possible in the safest condition of zero power. State-of-the-art safety analysis is including computer codes that use three dimensional neutron kinetics and thermohydraulics models. For the substantiation of such models, for its validation and verification there is a need in reactor experiments that implementing spatially distributed transients. We based on such statements when composing hot zero power physical startup program for the new VVER-1200 unit of Novovoronezh NPP. Several tests unconventional for VVER were developed for that program. It includes measuring the worth for each of control rod groups and measuring of single rod worth from the inserted groups - test that models rod ejection event in some sense.

  11. Characterization and BMP Tests of Liquid Substrates for High-rate Anaerobic Digestion

    Directory of Open Access Journals (Sweden)

    M. Mainardis

    2018-01-01

    Full Text Available This work was focused on the physicochemical characterization and biochemical methane potential (BMP tests of some liquid organic substrates, to verify if they were suitable for undergoing a process of high-velocity anaerobic digestion. The selected substrates were: first and second cheese whey, organic fraction of municipal solid waste (OFMSW leachate, condensate water and slaughterhouse liquid waste. Firstly, a physicochemical characterization was performed, using traditional and macromolecular parameters; then, batch anaerobic tests were carried out, and some continuous tests were planned. The results revealed that all the analyzed substrates have a potential to be anaerobically treated. Valuable information about treatment rate for a high-velocity anaerobic digestion process was obtained. Start-up of a lab-scale UASB reactor, treating diluted cheese whey, was successfully achieved with good COD removal efficiency. These preliminary results are expected to be further investigated in a successive phase, where continuous tests will be conducted on condensate water and OFMSW leachate.

  12. Comparing and characterizing transient and steady-state tests of the peripheral chemoreflex in humans.

    Science.gov (United States)

    Pfoh, Jamie R; Tymko, Michael M; Abrosimova, Maria; Boulet, Lindsey M; Foster, Glen E; Bain, Anthony R; Ainslie, Philip N; Steinback, Craig D; Bruce, Christina D; Day, Trevor A

    2016-03-01

    What is the central question of this study? We aimed to characterize the cardiorespiratory and cerebrovascular responses to transient and steady-state tests of the peripheral chemoreflex and to compare the hypoxic ventilatory responses (HVRs) between these tests. What is the main finding and its importance? The cardiovascular and cerebrovascular responses to transient tests were small in magnitude and short in duration. The steady-state isocapnic hypoxia test elicited a larger HVR than the transient 100% N(2) test, but the response magnitudes were correlated within individuals. The transient test of the HVR elicits fewer systemic effects than steady-state techniques and may have greater experimental utility than previously appreciated. Carotid chemoreceptors detect changes in arterial PO(2) and PCO(2), eliciting a peripheral chemoreflex (PCR). Steady-state (SS) hypoxia tests using dynamic end-tidal forcing (DEF) have been used to assess the hypoxic ventilatory response (HVR) but may be confounded by concomitant systemic effects. Transient tests of the PCR have also been developed but are not widely used, nor have the cardiovascular and cerebrovascular responses been characterized. We characterized the cardiorespiratory and cerebrovascular responses to transient tests of the PCR and compared the HVR between transient and SS-DEF tests. We hypothesized that the cardiovascular and cerebrovascular responses to the transient tests would be minimal and that the respiratory responses elicited from the transient and SS-DEF tests would be different in magnitude and not well correlated within individuals. Participants underwent five consecutive trials of two transient tests [three-breath 100% N(2) (TT-N(2)) and a single-breath 13% CO(2), in air] and two 10 min SS-DEF tests [isocapnic (SS-ISO) and poikilocapnic (SS-POI) hypoxia]. In response to the transient tests, heart rate, mean arterial pressure and the middle and posterior cerebral artery blood velocity increased (all P

  13. Nevada Test Site Perspective on Characterization and Loading of Legacy Transuranic Drums Utilizing the Central Characterization Project

    International Nuclear Information System (INIS)

    R.G. Lahoud; J. F. Norton; I. L. Siddoway; L. W. Griswold

    2006-01-01

    The Nevada Test Site (NTS) has successfully completed a multi-year effort to characterize and ship 1860 legacy transuranic (TRU) waste drums for disposal at the Waste Isolation Pilot Plant (WIPP), a permanent TRU disposal site. This has been a cooperative effort among the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO), the U.S. Department of Energy, Carlsbad Field Office (DOE/CBFO), the NTS Management and Operations (M and O) contractor Bechtel Nevada (BN), and various contractors under the Central Characterization Project (CCP) umbrella. The success is due primarily to the diligence, perseverance, and hard work of each of the contractors, the DOE/CBFO, and NNSA/NSO, along with the support of the U.S. Department of Energy, Headquarters (DOE/HQ). This paper presents, from an NTS perspective, the challenges and successes of utilizing the CCP for obtaining a certified characterization program, sharing responsibilities for characterization, data validation, and loading of TRU waste with BN to achieve disposal at WIPP from a Small Quantity Site (SQS) such as the NTS. The challenges in this effort arose from two general sources. First, the arrangement of DOE/CBFO contractors under the CCP performing work and certifying waste at the NTS within a Hazard Category 2 (HazCat 2) non-reactor nuclear facility operated by BN, presented difficult challenges. The nuclear safety authorization basis, safety liability and responsibility, conduct of operations, allocation and scheduling of resources, and other issues were particularly demanding. The program-level and field coordination needed for the closely interrelated characterization tasks was extensive and required considerable effort by all parties. The second source of challenge was the legacy waste itself. None of the waste was generated at the NTS. The waste was generated at Lawrence Livermore National Laboratory (LLNL), Lawrence Berkeley Laboratory (LBL), Lynchburg, Rocky

  14. Site characterization data from the Area 5 science boreholes, Nevada Test Site, Nye County, Nevada

    International Nuclear Information System (INIS)

    Blout, D.O.; Hammermeister, P.; Zukosky, K.A.

    1995-02-01

    The Science Borehole Project consists of eight boreholes that were drilled (from 45.7 m [150 ft] to 83.8 m [275 ft] depth) in Area 5 of the Nevada Test Site, Nye County, Nevada, on behalf of the US Department of Energy. These boreholes are part of the Area 5 Site Characterization Program developed to meet data needs associated with regulatory requirements applicable to the disposal of low-level and mixed waste at this site. This series of boreholes was specifically designed to characterize parameters controlling near-surface gas transport and to monitor changes in these and liquid flow-related parameters over time. These boreholes are located along the four sides of the approximately 2.6-km 2 (1-mi 2 ) Area 5 Radioactive Waste Management Site to provide reasonable spatial coverage for sampling and characterization. Laboratory testing results of samples taken from core and drill cuttings are reported

  15. Tests and standards for express-control of physical fitness and health of middle school age pupils

    Directory of Open Access Journals (Sweden)

    I.R. Bodnar

    2016-08-01

    Full Text Available Introduction: to day, physical fitness testing often causes negative emotions in pupils. It results in sharp loss of pupils’ wish to fulfill physical exercises in free time and worsens their health. Possibility to assess health level is an important motivation factor for pupils’ passing physical tests. Objective testing system will form positive motivation for physical exercises’ practicing and will facilitate increase of pupils’ motor functioning. It will also facilitate optimization of their physical condition, improvement of physical fitness and strengthening of health. Material: we tested physical fitness level and made diagnosis of pupils’ functional state (10-15 years’ age; n=85 with the help of tool methodic. We also used regressive analysis. Results: the system of tests and standards for express-control over physical fitness and health of middle school age pupils has been worked out and substantiated. The system of tests envisages fulfillment of 4 exercises: back pressing ups on bench during 20 seconds; throwing and catching of ball with two hands from wall during 30 seconds; side bending; torso rising from lying position into sitting during 30 seconds. Integral indicator of pupils’ physical fitness and health correlates with functional state of organism’s leading systems. We worked out 5 levels’ scale for express-control over physical fitness and health of middle school age pupils. The system stipulates calculation of integrative indicator with the help of regression equation by results of 4 test exercises and calculation of one index. Conclusions: The system of tests and standards permits the following: to divide pupils into relatively uniform groups even at the beginning of academic year for successful reasonable physical load. The system also permits to determine standard and find what shall be strived for by a pupil in order to achieve optimal physical fitness and somatic state; to motivate relatively weakly

  16. Advances on the constitutive characterization of composites via multiaxial robotic testing and design optimization

    Science.gov (United States)

    John G. Michopoulos; John Hermanson; Athanasios Iliopoulos

    2014-01-01

    The research areas of mutiaxial robotic testing and design optimization have been recently utilized for the purpose of data-driven constitutive characterization of anisotropic material systems. This effort has been enabled by both the progress in the areas of computers and information in engineering as well as the progress in computational automation. Although our...

  17. First industrial strength multi-axial Robotic testing campaign for composite material characterization

    Science.gov (United States)

    John G. Michopoulos; John C. Hermanson; Athanasios Iliopoulos

    2012-01-01

    In this paper we are reporting on the first successful campaign of systematic, automated and massive multiaxial tests for composite material constitutive characterization. The 6 degrees of freedom system developed at the Naval Research Laboratory (NRL) called NRL66.3, was used for this task. This was the inaugural run that served as the validation of the...

  18. Characterization of a standardized glucagon challenge test as a pharmacodynamic tool in pharmacological research

    NARCIS (Netherlands)

    van Dongen, M. G. J.; Geerts, B. F.; Bhanot, S.; Morgan, E. S.; de Kam, M. L.; Moerland, M.; Romijn, J. A.; Cohen, A. F.; Burggraaf, J.

    2014-01-01

    The aim of this study was to characterize a glucagon challenge test as a tool in diabetes research by assessing the inter- and intra-individual variability, and investigating the activity of the autonomic nervous system (ANS) during the challenge, as this might have an indirect impact on glucose

  19. Characterization of Ceramic Material Produced From a Cold Crucible Induction Melter Test

    Energy Technology Data Exchange (ETDEWEB)

    Amoroso, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Marra, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-04-30

    This report summarizes the results from characterization of samples from a melt processed surrogate ceramic waste form. Completed in October of 2014, the first scaled proof of principle cold crucible induction melter (CCIM) test was conducted to process a Fe-hollandite-rich titanate ceramic for treatment of high level nuclear waste. X-ray diffraction, electron microscopy, inductively coupled plasma-atomic emission spectroscopy (and inductively coupled plasma-mass spectroscopy for Cs), and product consistency tests were used to characterize the CCIM material produced. Core samples at various radial locations from the center of the CCIM were taken. These samples were also sectioned and analyzed vertically. Together, the various samples were intended to provide an indication of the homogeneity throughout the CCIM with respect to phase assemblage, chemical composition, and chemical durability. Characterization analyses confirmed that a crystalline ceramic with desirable phase assemblage was produced from a melt using a CCIM. Hollandite and zirconolite were identified in addition to possible highly-substituted pyrochlore and perovskite. Minor phases rich in Fe, Al, or Cs were also identified. Remarkably only minor differences were observed vertically or radially in the CCIM material with respect to chemical composition, phase assemblage, and durability. This recent CCIM test and the resulting characterization in conjunction with demonstrated compositional improvements support continuation of CCIM testing with an improved feed composition and improved melter system.

  20. Coupling LMDZ physics in WRF model: Aqua-planet configuration tests

    Science.gov (United States)

    Fita, Lluís; Hourdin, Frédéric; Fairhead, Laurent; Drobinski, Phlippe

    2014-05-01

    Nowadays advances in climatological sciences, pose different challenges for the current global climate models (GCM). One of them is related to the resolution. In some exercises, GCMs are started to be used to that resolutions to which they were not designed for, or in advance of future uses, they have to be tested in order to know their limitations. With the mid term perspective in mind of future uses of the Laboratorie de Météorologie Dynamique Zoom (LMDZ) model, a framework has been designed in order to use the physical parameterizations of the LMDZ model coupled to the dynamical core of Weather Research and Forecasting (WRF) model. This framework will allow the analysis of different aspects such as: resolution thresholds of the LMDZ physics set, skill of LMDZ physics in comparison with cloud resolving simulations, impact of the primitive equations fully compressible dynamics from WRF in global runs among others. The design and implementation of the framework keeps almost all the original capabilities of both models. As a first step, results of an ensemble of 1-year low-resolution global aqua-planet runs performed with the original models using different physical configurations, and the new framework will be presented. These initial results show the correct performance of the new framework, and the sensitivity of the global circulation due to different dynamical atmospheric cores and physical parameterizations.

  1. Multi-Attribute Seismic/Rock Physics Approach to Characterizing Fractured Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Gary Mavko

    2004-11-30

    Most current seismic methods to seismically characterize fractures in tight reservoirs depend on a few anisotropic wave propagation signatures that can arise from aligned fractures. While seismic anisotropy can be a powerful fracture diagnostic, a number of situations can lessen its usefulness or introduce interpretation ambiguities. Fortunately, laboratory and theoretical work in rock physics indicates that a much broader spectrum of fracture seismic signatures can occur, including a decrease in P- and S-wave velocities, a change in Poisson's ratio, an increase in velocity dispersion and wave attenuation, as well as well as indirect images of structural features that can control fracture occurrence. The goal of this project was to demonstrate a practical interpretation and integration strategy for detecting and characterizing natural fractures in rocks. The approach was to exploit as many sources of information as possible, and to use the principles of rock physics as the link among seismic, geologic, and log data. Since no single seismic attribute is a reliable fracture indicator in all situations, the focus was to develop a quantitative scheme for integrating the diverse sources of information. The integrated study incorporated three key elements: The first element was establishing prior constraints on fracture occurrence, based on laboratory data, previous field observations, and geologic patterns of fracturing. The geologic aspects include analysis of the stratigraphic, structural, and tectonic environments of the field sites. Field observations and geomechanical analysis indicates that fractures tend to occur in the more brittle facies, for example, in tight sands and carbonates. In contrast, strain in shale is more likely to be accommodated by ductile flow. Hence, prior knowledge of bed thickness and facies architecture, calibrated to outcrops, are powerful constraints on the interpreted fracture distribution. Another important constraint is that

  2. Development of computerized adaptive testing (CAT) for the EORTC QLQ-C30 physical functioning dimension

    DEFF Research Database (Denmark)

    Petersen, Morten Aa; Groenvold, Mogens; Aaronson, Neil K

    2011-01-01

    Computerized adaptive test (CAT) methods, based on item response theory (IRT), enable a patient-reported outcome instrument to be adapted to the individual patient while maintaining direct comparability of scores. The EORTC Quality of Life Group is developing a CAT version of the widely used EORTC...... QLQ-C30. We present the development and psychometric validation of the item pool for the first of the scales, physical functioning (PF)....

  3. Synthetic aperture radar images of ocean waves, theories of imaging physics and experimental tests

    Science.gov (United States)

    Vesecky, J. F.; Durden, S. L.; Smith, M. P.; Napolitano, D. A.

    1984-01-01

    The physical mechanism for the synthetic Aperture Radar (SAR) imaging of ocean waves is investigated through the use of analytical models. The models are tested by comparison with data sets from the SEASAT mission and airborne SAR's. Dominant ocean wavelengths from SAR estimates are biased towards longer wavelengths. The quasispecular scattering mechanism agrees with experimental data. The Doppler shift for ship wakes is that of the mean sea surface.

  4. Physical examination tests of the shoulder: a systematic review and meta-analysis of diagnostic test performance.

    Science.gov (United States)

    Gismervik, Sigmund Ø; Drogset, Jon O; Granviken, Fredrik; Rø, Magne; Leivseth, Gunnar

    2017-01-25

    Physical examination tests of the shoulder (PETS) are clinical examination maneuvers designed to aid the assessment of shoulder complaints. Despite more than 180 PETS described in the literature, evidence of their validity and usefulness in diagnosing the shoulder is questioned. This meta-analysis aims to use diagnostic odds ratio (DOR) to evaluate how much PETS shift overall probability and to rank the test performance of single PETS in order to aid the clinician's choice of which tests to use. This study adheres to the principles outlined in the Cochrane guidelines and the PRISMA statement. A fixed effect model was used to assess the overall diagnostic validity of PETS by pooling DOR for different PETS with similar biomechanical rationale when possible. Single PETS were assessed and ranked by DOR. Clinical performance was assessed by sensitivity, specificity, accuracy and likelihood ratio. Six thousand nine-hundred abstracts and 202 full-text articles were assessed for eligibility; 20 articles were eligible and data from 11 articles could be included in the meta-analysis. All PETS for SLAP (superior labral anterior posterior) lesions pooled gave a DOR of 1.38 [1.13, 1.69]. The Supraspinatus test for any full thickness rotator cuff tear obtained the highest DOR of 9.24 (sensitivity was 0.74, specificity 0.77). Compression-Rotation test obtained the highest DOR (6.36) among single PETS for SLAP lesions (sensitivity 0.43, specificity 0.89) and Hawkins test obtained the highest DOR (2.86) for impingement syndrome (sensitivity 0.58, specificity 0.67). No single PETS showed superior clinical test performance. The clinical performance of single PETS is limited. However, when the different PETS for SLAP lesions were pooled, we found a statistical significant change in post-test probability indicating an overall statistical validity. We suggest that clinicians choose their PETS among those with the highest pooled DOR and to assess validity to their own specific clinical

  5. A standardization of the physical tests for external irradiation measuring detectors

    International Nuclear Information System (INIS)

    1977-05-01

    This report is the result of a standardization work, realized within the Radioprotection Services of the A.E.C., of the physical tests for dectors measuring external irradiations. Among the various tests mentionned, calibration and the establishment of the relative spectral response are treated in details. As far as calibration is concerned, the standardization refers to: the reference detector, the reference radiation source, the installation and calibration procedure. As for the relative spectral response the standardization refers to: the reference detector, the radiation sources to be used. High flux detectors and those for pulse electromagnetic radiations are also dealt with [fr

  6. An Empirical Analysis of the Physical Aptitude Exam as a Predictor of Performance on the Physical Readiness Test

    National Research Council Canada - National Science Library

    Patrick, Robert

    2000-01-01

    The Physical Aptitude Exam, administered to candidates in the Naval Academy admissions process to measure physical aptitude, consists of pullups for men or the flexed arm hang for women, a 300-yard...

  7. Validation of PROMIS ® Physical Function computerized adaptive tests for orthopaedic foot and ankle outcome research.

    Science.gov (United States)

    Hung, Man; Baumhauer, Judith F; Latt, L Daniel; Saltzman, Charles L; SooHoo, Nelson F; Hunt, Kenneth J

    2013-11-01

    In 2012, the American Orthopaedic Foot & Ankle Society(®) established a national network for collecting and sharing data on treatment outcomes and improving patient care. One of the network's initiatives is to explore the use of computerized adaptive tests (CATs) for patient-level outcome reporting. We determined whether the CAT from the NIH Patient Reported Outcome Measurement Information System(®) (PROMIS(®)) Physical Function (PF) item bank provides efficient, reliable, valid, precise, and adequately covered point estimates of patients' physical function. After informed consent, 288 patients with a mean age of 51 years (range, 18-81 years) undergoing surgery for common foot and ankle problems completed a web-based questionnaire. Efficiency was determined by time for test administration. Reliability was assessed with person and item reliability estimates. Validity evaluation included content validity from expert review and construct validity measured against the PROMIS(®) Pain CAT and patient responses based on tradeoff perceptions. Precision was assessed by standard error of measurement (SEM) across patients' physical function levels. Instrument coverage was based on a person-item map. Average time of test administration was 47 seconds. Reliability was 0.96 for person and 0.99 for item. Construct validity against the Pain CAT had an r value of -0.657 (p foot and ankle surgery. Further validation of the PROMIS(®) item banks may ultimately provide a valid and reliable tool for measuring patient-reported outcomes after injuries and treatment.

  8. OVERALL ASSESSMENT OF PHYSICAL FITNESS IN CHILDREN WITH MENTAL RETARDATION IN THE TEST "EUROFIT SPECIAL"

    Directory of Open Access Journals (Sweden)

    Bartosz Bolach

    2013-12-01

    Full Text Available Purpose. The aim of this research was to assess general extensive physical efficiency in children suffering from moderate mental disability with the use of “Eurofit Special” tests, and to compare general extensive physical efficiency and its components in the aspect of sexual dimorphism (Rohrer index. The research presents the problem of mental imparity (epidemiology, classification and the issue of extensive physical efficiency. Material, methods. The research included 52 pupils (25 girls and 27 boys, aged 10-14 from Wroclaw Centre of Education and Rehabilitation of the Disabled. Results. The results of the tests proved the existence of differences in somatic body constitution of boys and girls. However, statistically significant differences between the “Eurofit Special” test results were not observed with reference to children’s sex or the correlation between somatic constitution and achieved results. Conclusions. Somatic constitution of boys and girls aged between 10 and 14 was clearly different, and most visible in the average values of Rohrer’s index, with these values being higher among girls.

  9. Research, development, and preliminary testing of interactive engagements for teaching quantum mechanics to undergraduate physics majors

    Science.gov (United States)

    Axmann, Waldemar Jay

    The Advanced Visual Quantum Mechanics project was conceived to provide computer-centered, activities-based instructional materials to upper-level undergraduate physics majors. This study implements one curriculum development cycle of research, development, and classroom testing for a single unit, The Shape and Behavior of the Wave Function, of these materials. It is designed to be a proof of concept pilot study for the project. The cycle began with an extensive review of existing research drawing on results from the general fields of cognitive science and educational research as well as more specific research regarding the use of computers in instruction and the teaching and learning of quantum mechanics. It continued with the development of written materials, a computer program, and assessment instruments all extensively based on this research. It concluded with a field test garnering an outcome of positive student and instructor attitudes and perceptions of learning gains as well as actual gains similar or superior to traditional instruction---even in the face of usage that diverged widely from that intended. Based on these results, we recommend the continuation of the Advanced Visual Quantum Mechanics project. This work would include further testing and revision of these materials, similar development and classroom testing of further materials, and new research within the context of that testing. Consideration should also be given to similar projects that address other physics subject areas.

  10. Experimental characterization and physical modelling of the dose distribution of scanned proton pencil beams

    International Nuclear Information System (INIS)

    Pedroni, E; Scheib, S; Boehringer, T; Coray, A; Grossmann, M; Lin, S; Lomax, A

    2005-01-01

    In this paper we present the pencil beam dose model used for treatment planning at the PSI proton gantry, the only system presently applying proton therapy with a beam scanning technique. The scope of the paper is to give a general overview on the various components of the dose model, on the related measurements and on the practical parametrization of the results. The physical model estimates from first physical principles absolute dose normalized to the number of incident protons. The proton beam flux is measured in practice by plane-parallel ionization chambers (ICs) normalized to protons via Faraday-cup measurements. It is therefore possible to predict and deliver absolute dose directly from this model without other means. The dose predicted in this way agrees very well with the results obtained with ICs calibrated in a cobalt beam. Emphasis is given in this paper to the characterization of nuclear interaction effects, which play a significant role in the model and are the major source of uncertainty in the direct estimation of the absolute dose. Nuclear interactions attenuate the primary proton flux, they modify the shape of the depth-dose curve and produce a faint beam halo of secondary dose around the primary proton pencil beam in water. A very simple beam halo model has been developed and used at PSI to eliminate the systematic dependences of the dose observed as a function of the size of the target volume. We show typical results for the relative (using a CCD system) and absolute (using calibrated ICs) dosimetry, routinely applied for the verification of patient plans. With the dose model including the nuclear beam halo we can predict quite precisely the dose directly from treatment planning without renormalization measurements, independently of the dose, shape and size of the dose fields. This applies also to the complex non-homogeneous dose distributions required for the delivery of range-intensity-modulated proton therapy, a novel therapy technique

  11. Chemical, physical and isotopic characterization of U3Si2, for nuclear forensics purposes

    International Nuclear Information System (INIS)

    Rosa, Daniele Scarpim

    2011-01-01

    In the early 1990's, the first illicit trafficking of nuclear and radioactive materials was observed mainly in Europe. A decade marked by numerous cases of seizures of these materials. As a result, these events have become the subject of criminal forensic investigations and develop from there, nuclear forensics. In Brazil there are no illicit trafficking official records of nuclear material, however, is widely known the extraction and illegal transportation of radioactive geological materials, and the materials pieces attachment used as shielding for radioactive sources. One of the main tools used in nuclear forensics is the nuclear materials databases establishment. These documents must contain the most information as possible about the physical, chemical and nuclear material seized, allowing the identification of their origin, manufacturing process or age. Thus, it sets characteristic composition standards of each material, called 'chemical signatures' (chemical finger print). In this work nuclear forensic protocol was adopted as well as the three stages of assessment suggested by International Atomic Energy Agency (IAEA) in identifying the origin of uranium silicide (U 3 Si 2 ). Assays were performed in order to make physical, chemical and isotopic characterization of the studied materials and compared the data with those obtained for other uranium compounds (Uranium tetrafluoride, UF 4 ; uranium oxide, UO 2 and U 3 O 8 ; Yellow cake) by establishing a characteristic signature for each one. Through the assays the uranium compounds were classify by origin groups, as far as they are from different manufactured process and/ or origin. It was also possible to show the importance of a nuclear forensic database during an investigation of a nuclear forensic event. (author)

  12. Evaluation of standardized test methods to characterize fiber reinforced cement composites

    DEFF Research Database (Denmark)

    Paegle, Ieva; Fischer, Gregor

    2011-01-01

    This paper describes an investigation of standardized test methods to characterize fiber reinforced cementitious composites in terms of their behavior under flexural loading and its relation to their tensile stress-deformation response. Flexural testing and derivation of the tensile stress......-deformation response are preferred in standardized testing of Fiber Reinforced Cement Composites (FRCC) over the direct assessment of the tensile behavior because of the more convenient test setup and ease of specimen preparation. Four-point bending tests were carried out to evaluate the flexural response of FRCC...... and their results are compared to data obtained from direct tensile testing. The details of the formation of cracking are an important underlying assumption in the standardized evaluation procedures as well as in the established correlation models between flexural and tensile behavior. This detail has been...

  13. Development of indirect ring tension test for fracture characterization of asphalt mixtures

    Science.gov (United States)

    Zeinali Siavashani, Alireza

    Low temperature cracking is a major distress in asphalt pavements. Several test configurations have been introduced to characterize the fracture properties of hot mix (HMA); however, most are considered to be research tools due to the complexity of the test methods or equipment. This dissertation describes the development of the indirect ring tension (IRT) fracture test for HMA, which was designed to be an effective and user-friendly test that could be deployed at the Department of Transportation level. The primary advantages of this innovative and yet practical test include: relatively large fracture surface test zone, simplicity of the specimen geometry, widespread availability of the required test equipment, and ability to test laboratory compacted specimens as well as field cores. Numerical modeling was utilized to calibrate the stress intensity factor formula of the IRT fracture test for various specimen dimensions. The results of this extensive analysis were encapsulated in a single equation. To develop the test procedure, a laboratory study was conducted to determine the optimal test parameters for HMA material. An experimental plan was then developed to evaluate the capability of the test in capturing the variations in the mix properties, asphalt pavement density, asphalt material aging, and test temperature. Five plant-produced HMA mixtures were used in this extensive study, and the results revealed that the IRT fracture test is highly repeatable, and capable of capturing the variations in the fracture properties of HMA. Furthermore, an analytical model was developed based on the viscoelastic properties of HMA to estimate the maximum allowable crack size for the pavements in the experimental study. This analysis indicated that the low-temperature cracking potential of the asphalt mixtures is highly sensitive to the fracture toughness and brittleness of the HMA material. Additionally, the IRT fracture test data seemed to correlate well with the data from

  14. Evaluation of a draft standard on performance specifications for health physics instrumentation: results for environmental tests

    International Nuclear Information System (INIS)

    Kenoyer, J.L.; Swinth, K.L.; Mashburn, K.R.; Selby, J.M.

    1984-06-01

    Draft ANSI Standard N42.17 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. Evaluation is performed by testing a cross-section of currently available instruments with testing procedures based on specifications of the standard and then determining the degree of conformance to the various elements of the proposed standard. Data will be presented on the performance of a cross-section of beta-gamma survey instruments under various environmental tests. Test results that will be presented include temperature effects, humidity effects, radio frequency (r.f.) susceptibility, ambient pressure effects, vibration effects, and shock effects. Tests performed to date show that most instruments will meet the temperature, humidity, and ambient pressure tests. A large variability is noted among instruments from the same or different vendors. Preliminary r.f. susceptibility tests have shown large artificial responses at some frequencies for specific instruments. The presentation will also include a discussion of procedures used in the testing and weaknesses identified in the proposed standard

  15. A Physical Protection Systems Test Bed for International Counter-Trafficking System Development

    International Nuclear Information System (INIS)

    Stinson, Brad J.; Kuhn, Michael J.; Donaldson, Terrence L.; Richardson, Dave; Rowe, Nathan C.; Younkin, James R.; Pickett, Chris A.

    2011-01-01

    Physical protection systems have a widespread impact on the nuclear industry in areas such as nuclear safeguards, arms control, and trafficking of illicit goods (e.g., nuclear materials) across international borders around the world. Many challenges must be overcome in design and deployment of foreign border security systems such as lack of infrastructure, extreme environmental conditions, limited knowledge of terrain, insider threats, and occasional cultural resistance. Successful security systems, whether it be a system designed to secure a single facility or a whole border security system, rely on the entire integrated system composed of multiple subsystems. This test bed is composed of many unique sensors and subsystems, including wireless unattended ground sensors, a buried fiber-optic acoustic sensor, a lossy coaxial distributed sensor, wireless links, pan-tilt-zoom cameras, mobile power generation systems, unmanned aerial vehicles, and fiber-optic-fence intrusion detection systems. A Common Operating Picture software architecture is utilized to integrate a number of these subsystems. We are currently performance testing each system for border security and perimeter security applications by examining metrics such as probability of sense and a qualitative understanding of the sensors vulnerability of defeat. The testing process includes different soil conditions for buried sensors (e.g., dry, wet, and frozen) and an array of different tests including walking, running, stealth detection, and vehicle detection. Also, long term sustainability of systems is tested including performance differences due to seasonal variations (e.g. summer versus winter, while raining, in foggy conditions). The capabilities of the test bed are discussed. Performance testing results, both at the individual component level and integrated into a larger system for a specific deployment (in situ), help illustrate the usefulness and need for integrated testing facilities to carry out this

  16. Electrostatic discharge attenuation test for the characterization of ESD protective materials

    Energy Technology Data Exchange (ETDEWEB)

    Paasi, Jaakko [VTT Technical Research Centre of Finland, PO Box 1300, FI-33101 Tampere (Finland); Viheriaekoski, Toni; Sutela, Lassi [Nokia Corporation, PO Box 370, FI-00045 Nokia Group, Espoo (Finland); Tamminen, Pasi K [Nokia Corporation, Visiokatu 3, FI-33721 Tampere (Finland)], E-mail: jaakko.paasi@vtt.fi

    2008-12-01

    New experimental method has been developed to evaluate materials, tools, equipment and packaging used in the electronics production environment under Charged Device Model (CDM) type of electrostatic discharge (ESD) transients. The method is intended to characterize the ability of the material or object to attenuate ESD energy and peak discharge current when a charged device is discharged into the material under test. The test is supplementary for the standard quasi-static measurements of ESD control programs in the cases where standard measurements do not give sufficient information due to voltage non-linearity, complexity or shape of the material or object under test.

  17. Electrostatic discharge attenuation test for the characterization of ESD protective materials

    International Nuclear Information System (INIS)

    Paasi, Jaakko; Viheriaekoski, Toni; Sutela, Lassi; Tamminen, Pasi K

    2008-01-01

    New experimental method has been developed to evaluate materials, tools, equipment and packaging used in the electronics production environment under Charged Device Model (CDM) type of electrostatic discharge (ESD) transients. The method is intended to characterize the ability of the material or object to attenuate ESD energy and peak discharge current when a charged device is discharged into the material under test. The test is supplementary for the standard quasi-static measurements of ESD control programs in the cases where standard measurements do not give sufficient information due to voltage non-linearity, complexity or shape of the material or object under test.

  18. RF characterization and testing of ridge waveguide transitions for RF power couplers

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Rajesh; Jose, Mentes; Singh, G.N. [Ion Accelerator Development Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Kumar, Girish [Department of Electrical Engineering, IIT Bombay, Mumbai 400076,India (India); Bhagwat, P.V. [Ion Accelerator Development Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)

    2016-12-01

    RF characterization of rectangular to ridge waveguide transitions for RF power couplers has been carried out by connecting them back to back. Rectangular waveguide to N type adapters are first calibrated by TRL method and then used for RF measurements. Detailed information is obtained about their RF behavior by measurements and full wave simulations. It is shown that the two transitions can be characterized and tuned for required return loss at design frequency of 352.2 MHz. This opens the possibility of testing and conditioning two transitions together on a test bench. Finally, a RF coupler based on these transitions is coupled to an accelerator cavity. The power coupler is successfully tested up to 200 kW, 352.2 MHz with 0.2% duty cycle.

  19. How well do physical activity questions perform? A European cognitive testing study.

    Science.gov (United States)

    Finger, J D; Gisle, L; Mimilidis, H; Santos-Hoevener, C; Kruusmaa, E K; Matsi, A; Oja, L; Balarajan, M; Gray, M; Kratz, A L; Lange, C

    2015-01-01

    Only few studies have focused on the cognitive processes of the respondents that are involved when answering physical activity questionnaires (PAQs). This study aimed at examining whether two PAQs work as intended with different segments of the survey population in different cultural settings in Europe. The International Physical Activity Questionnaire - Short Form (IPAQ-SF) and the US National Health Interview Survey - Adult Core Physical Activity Questionnaire (NHIS-PAQ) were tested in Belgium, Estonia, Germany and the UK using a standardized cognitive interviewing procedure. IPAQ-SF measures total vigorous physical activity (PA), moderate PA, walking and sitting. NHIS-PAQ measures leisure-time vigorous PA, light and moderate PA and muscle-strengthening PA. In total 62 persons completed cognitive interviews, at least 15 interviews were conducted in each country. Both PAQs performed as intended with young and high-skilled persons and those having a regular exercise schedule. For the others, however, the testing revealed that problems occurred with both PAQs relating to understanding the concepts of '(light and) moderate' and 'vigorous' PA, classifying activities into the provided answer options of different PA intensities, recalling instances of 'normal' activities such as walking and sitting, and calculating the total duration of more than one activity or instance of an activity. The revealed problems with the questionnaires were quite similar in different countries; profound cultural differences were not observed. Both questionnaires were difficult to answer for many respondents and rather user-unfriendly. They are designed to measure an exactness of PA quantity (frequency and duration) and intensity which would be desirable to obtain from a scientific point of view; however, respondents can hardly provide this information for cognitive reasons. Studies investigating the respondents' perspective are useful for improving physical activity information based on

  20. 8th RILEM International Symposium on Testing and Characterization of Sustainable and Innovative Bituminous Materials

    CERN Document Server

    Partl, Manfred

    2016-01-01

    This work presents the results of RILEM TC 237-SIB (Testing and characterization of sustainable innovative bituminous materials and systems). The papers have been selected for publication after a rigorous peer review process and will be an invaluable source to outline and clarify the main directions of present and future research and standardization for bituminous materials and pavements. The following topics are covered: - Characterization of binder-aggregate interaction - Innovative testing of bituminous binders, additives and modifiers - Durability and aging of asphalt pavements - Mixture design and compaction analysis - Environmentally sustainable materials and technologies - Advances in laboratory characterization of bituminous materials - Modeling of road materials and pavement performance prediction - Field measurement and in-situ characterization - Innovative materials for reinforcement and interlayer systems - Cracking and damage characterization of asphalt pavements - Rec...

  1. Physical Characterization Of High Amylose/Pectin Mixtures Cross-Linked With Sodium Trimetaphosphate

    International Nuclear Information System (INIS)

    Carbinatto, F.M.; Cury, B.S.F.; Evangelista, R.C.

    2010-01-01

    Some researches have reported that pectin and high amylose mixtures presented superior mechanical properties in relation to those of the isolated polymers. In this work, mixtures at different ratios (1:4; 1:1) of pectin and high amylose were crosslinked with sodium trimetaphosphate at different degrees by varying reaction conditions. All samples were characterized by rheological and X-ray diffraction analyses. Samples without cross-linker were prepared as control. The oscillatory dynamic tests showed that all samples exhibited predominant elastic behavior, although cross-linked samples presented higher G' values, suggesting that crosslinking by phosphorylation resulted in more strength structures. The diffractograms showed that cross-linked samples underwent structural modifications that resulted in increase of crystallinity due to cross-linking process. (author)

  2. Site characterization and monitoring data from Area 5 Pilot Wells, Nevada Test Site, Nye County, Nevada

    International Nuclear Information System (INIS)

    1994-02-01

    The Special Projects Section (SPS) of Reynolds Electrical ampersand Engineering Co., Inc. (REECO) is responsible for characterizing the subsurface geology and hydrology of the Area 5 Radioactive Waste Management Site (RWMS) at the Nevada Test Site (NTS) for the US Department of Energy, Nevada Operations Office (DOE/NV), Environmental Restoration and Waste Management Division, Waste Operations Branch. The three Pilot Wells that comprise the Pilot Well Project are an important part of the Area 5 Site Characterization Program designed to determine the suitability of the Area 5 RWMS for disposal of low-level waste (LLW), mixed waste (MW), and transuranic waste (TRU). The primary purpose of the Pilot Well Project is two-fold: first, to characterize important water quality and hydrologic properties of the uppermost aquifer; and second, to characterize the lithologic, stratigraphic, and hydrologic conditions which influence infiltration, redistribution, and percolation, and chemical transport through the thick vadose zone in the vicinity of the Area 5 RWMS. This report describes Pilot Well drilling and coring, geophysical logging, instrumentation and stemming, laboratory testing, and in situ testing and monitoring activities

  3. Hydrogeological site characterization of marly-silici-calcareous rocks through surveys of discontinuities and pumping tests

    Directory of Open Access Journals (Sweden)

    Francesca Lotti

    2012-06-01

    Full Text Available One of the challenges in the characterization of fractured aquifers is to define whether the approximation to a porous medium is valid or not. In this context, the present study concerns the hydrogeological characterization of a small area constituted by densely fractured marly-silici-calcareous rocks. The hydrogeological investigations included fracture network surveys and pumping tests. The survey of the outcrops showed a rock mass characterized by a high number of persistent discontinuities with a wide spatial distribution, high frequency and a wide range of values of the aperture in the different systems. These characteristics imply the possibility of considering the rock mass as an equivalent porous medium at the outcrop scale. Pumping tests highlighted a consistent reaction of the various monitoring points and a similar trend of the drawdown-time curve, resulting in considering the aquifer as continuous medium at the scale of the volume influenced by pumping. The drawdown maps seems to be related to a weak anisotropy of the aquifer in the horizontal plane with the major axis of the ellipse aligned along the direction NE-SW, consistent with the directions of the principal components of the hydraulic conductivity resulting from the hydraulic model of the rock mass. Although the aquifer can be considered an equivalent anisotropic porous medium at the scale of the study, the comparison between the results of pumping tests and of the rock mass survey indicates that this approach would be not sufficient to characterize groundwater movement.

  4. Morphological investigation and physical characterization of ancient fragments of pyrogenic carbon

    International Nuclear Information System (INIS)

    Pusceddu, E; Miglietta, F; Criscuoli, I

    2013-01-01

    In the latest years, the attention toward the use of pyrogenic carbon as a climate mitigation strategy has increasingly grown. Biochar (BC) contains substantial amount (60–90%) of pyrogenic carbon, which is a recalcitrant material and it is hardly decomposed by biotic and abiotic oxidation. The carbon mitigation potential of biochar is associated to the fact that carbon is not easily released back into the atmosphere, even after very long incubation time in the soil. Several studies have been addressing the understanding of the fate of pyrogenic carbon in the soil in a quantitative way, but only a few actually considered materials that were produced in the past and they were not fully able to estimate the fraction of carbon that was oxidized on centennial time scales. In this paper, an old deposits of biochar in soils of the Eastern Alps (Trentino, Val di Pejo) was dated at 1859 by means of a dendroanthracological approach. Carbon decomposition in those soils was then investigated to calculate the fraction of carbon that was lost over 155 years. Part of this study is focused on the morphological and physical characterization of several fragments of biochar, using a scanning electron microscope (SEM). Such study enabled the identification of specific morphological features of tracheids in the old biochar, which were tentatively associated to a differential oxidation of the structures that were created during carbonization from lignin and cellulose

  5. Leads from Physical, Chemical, and Thermal Characterization on Cytotoxic Effects of Xylan-Based Microparticles

    Directory of Open Access Journals (Sweden)

    Henrique Rodrigues Marcelino

    2015-11-01

    Full Text Available Interfacial cross-linking (ICL has been considered a feasible technique to produce polysaccharide-based microparticles (PbMs, even though only a few studies have been concerned with their biocompatibility. In this work, PbMs were prepared by the ICL method and characterized in regard to their in vitro biocompatibility, chemical linkages, and physical and thermal properties. First, the cell viability assay revealed that PbMs toxicity was concentration-dependent. Then, it was observed that the toxicity may be related to the way in which the binding occurred, and not exclusively to the stoichiometry between the polymer and the cross-linking agent. Moreover, the PbMs biosafety was predicted by the use of physicochemical procedures, which were able to identify unbound cross-linking agent residues and also to reveal the improvement of their thermal stability. Accordingly, this work suggests a step-by-step physicochemical procedure able to predict potential toxicity from micro-structured devices produced by polysaccharides. Likewise, the use of PbMs as a drug carrier should be cautiously considered.

  6. Physical-chemical characterization of bovine bone ash for evaluating its potential agricultural use

    Directory of Open Access Journals (Sweden)

    Eduardo Pacca Luna Mattar

    2014-03-01

    Full Text Available The manufacturing of bovine bone ash is a low cost and easy production process which can be adopted for making good use of animal residues, in locations without infrastructure, such as the family production units. This study aimed at describing the manufacturing process of bone ash and characterizing the physical and chemical parameters of the resulting material for organic fertilization. The experiment was performed with three replications, being evaluated the bovine bone ash manufacturing process yield, as well as its density, water retention capacity, pH of the resulting material after burning and contents of total calcium, calcium soluble in water, total phosphorus and phosphorus soluble in citric acid and in ammonium citrate. The process resulted in an average yield of 24.4% and the bovine bone ash presented 33.07% of total calcium, 15.6% of total phosphorus, 10.4% of phosphorus soluble in citric acid, pH of 9.94, density of 0.89 g cm-3 and water retention capacity of 73.3%. The bovine bone ash showed promising characteristics, with potential for being used as source of phosphorus and calcium in the organic fertilization process.

  7. [Physical, culinary and nutritional characterization in dry bean from the highlands of Mexico].

    Science.gov (United States)

    Pérez Herrera, Patricia; Esquivel Esquivel, Gilberto; Rosales Serna, Rigoberto; Acosta-Gallegos, Jorge

    2002-06-01

    In the improvement of a given crop species, knowledge on the grain quality and related traits in the progenitors used in the breeding process is needed to establish their usefulness as a source of a given character, and as well as to plan the proper combinations between progenitors. The aim of the present research was to characterize a group of 49 genotypes of Phaseolus vulgaris and one of Phaseolus coccineus, in relation to physical, cooking and nutritional grain traits. Cultivar Blanco Tlaxcala (P. coccineus) showed a larger grain size and lower protein content than any of the P. vulgaris cultivars. The 86% of the studied genotypes showed cooking times lower to 115 min, and a significant correlation between this trait and water sorption capacity (r = 0.78 **) was found. Cultivars Redlands Pioneer and ICA Zerinza could be used as source of low cooking time; and Perry Marrow, Kaboon and ICA Zerinza in the production of low shell content cultivars. Genotypes G 2333, Negro Lolotla, REN 27 and J 117 showed the highest grain protein content. On the other hand, BY 94022, Pinto Villa and Negro 150 had the lowest trypsin inhibitor activity. Results support the possible use of the above genotypes as sources of those grain traits. In general, large variability was found for most of the quality traits determined; therefore, there is scope for improvement through recombination and selection.

  8. PHYSICAL, PHYSICOCHEMICAL AND TAXONOMIC CHARACTERIZATION OF PSIDIUM ARAÇA RADDI

    Directory of Open Access Journals (Sweden)

    Maria do Rosário Fátima Padilha

    2016-10-01

    Full Text Available New research has stimulated a large reevaluation of species with regards to the use of fruits from native plants. Araçá (a small Brazilian guava-like fruit is found scattered in the wild in Pernambuco/Brazil. There is a scarcity of detailed studies on such regional fruit trees, especially the Psidium araçá Raddi species, whereas there is an enormous possibility to explore the potential offered by these fruits, such as in the field of gastronomy, where the search for new ingredients and exotic flavors associated with functional properties has been increasing. This article aimed to evaluate the physical, physicochemical and taxonomic characterization of araçá obtained from different agricultural regions of Pernambuco in order to investigate the possibility of developing new products from this native fruit. The taxonomic identification confirmed that all collected material belonged to the species P. araçá Raddi. An average weight of 7.45 g/fruit was observed. With respect to pH, values between 3.17 and 3.48 were found, and the acidity as a percentage of citric acid was on the order of 0.96% to 0.99%. It was shown that the P. araçá Raddi fruit has a desirable quality for the food industry, presenting excellent conditions for the development of formulations of high commercial value and promising application in the national gastronomy.

  9. Rheological characterization of novel physically crosslinked terpolymeric hydrogels at different temperatures

    Science.gov (United States)

    Malana, Muhammad Aslam; Zohra, Rubab; Khan, Muhammad Saleem

    2012-09-01

    The main objective of this research work is to reveal the detailed and extensive rheological characterization of terpolymeric hydrogel formulations using a variety of monomers having different concentrations of acrylic acid and applying a range of temperatures. The hydrogels with the different concentrations of acrylic acid were prepared in the absence of air using three different monomers, by free radical polymerization, gradually increasing the temperature up to polymerization point, using ethyl alcohol as solvent. Different shear measurements were performed to study rheological properties, temperature dependence, and yield strength of acrylic acid pharmaceutical hydrogels. Various models were applied to analyze the rheological behavior of the gels. The acrylic acid pharmaceutical gels having physical cross links in the gel networks, exhibit remarkable temperature dependence especially with relatively higher concentration of acrylic acid at greater shear rate. Flow curves plotted at various temperatures indicate that these gels exhibit a reasonable pseudoplastic behavior. All these hydrogels require appropriate yield strength to break their network structures. The gel samples exhibit the best fit to the Modified Bingham model, which can explain the overall flow behavior of these topical gels. The rheological analysis indicates that these gels may be used as topical gels for targeted and controlled drug delivery at a specific site.

  10. Clays for brick manufacturing in Actopan, Hidalgo: physical, chemical and mineralogical characterization

    International Nuclear Information System (INIS)

    Moreno-Tovar, Raul; Yañez-Hernández, Osiris Annel; Pérez-Moreno, Fidel; Rodríguez-Lugo, Ventura; Rivera, José de Jesús Cruz; Rivera, Ana Leonor

    2017-01-01

    Samples of clays from Actopan, Hidalgo employed in brick manufacturing are physical, chemical and mineralogical characterized. Transmitted polarized light microscopy showed a uniform particle size with grain morphology characteristic of euhedral crystals with quartz, feldspars, nontronite, and iron oxides particles. Scanning Electron Microscopy revealed 75 μm to 90 μm wide subhedral structures formed by particles from 2.0 μm to 5.0 μm; and rombohedrales forms 40 μm wide, 70 µm long, constituted of silicon, aluminum, iron, titanium, calcium, minor amounts of potassium, magnesium, and sodium. Minerals such as quartz, albite, cristobalite, calcium and Hematite phases were recognized by X-Ray Diffraction technique. Chemical analysis by atomic emission spectrometry with Inductively Coupled Plasma confirmed this mineralogy composition while laser granulometry method found the same particle size. Grain size analysis determined submicrometric dimensions, and multimodal type curves, that can be interpreted as the mixing of two or more different mineral phases in each sample. (author)

  11. Physical and chemical characterization of hydrolyzed Napier grass waste for biomass pellets

    Directory of Open Access Journals (Sweden)

    Duangkanok Tanangteerapong

    2017-09-01

    Full Text Available Utilizing agricultural waste for energy and to conserve the environment has been an active research area recently. In this study, Napier grass waste resulting from its hydrolysis with acids was pelletized and its use was studied as a biomass fuel. An investigation of its physical characteristics, including pellet dimensions and weight, was performed at a laboratory scale. Flat-faced pellets were obtained with enhanced stability necessary for transportation. Chemical characterization of the hydrolyzed waste included determination of its nitrogen, chloride and sulfur content. These values were marginal. After pelletization, experimental determination of its heating values, moisture content and density was examined. It was found that these values exceeded the European standard for biomass pellets. The average of heating value of pelletized biomass was greater than 3500 cal/g. Therefore, a binding material was not necessary. Overall, the investigation revealed that the pellets produced from hydrolyzed Napier grass waste could potentially be exploited as an alternative energy source after some residual chemicals were removed.

  12. Physical-mechanical and anatomical characterization in 26-year-old Eucalyptus resinifera wood

    Directory of Open Access Journals (Sweden)

    Israel Luiz de Lima

    Full Text Available In the present study, we aimed to characterize Eucalyptus resinifera wood through physical and mechanical assays and wood anatomy studies, as well as determine the relationships between the properties and anatomy of wood. We used samples collected from the area close to the bark of ten 26-year-old E. resinifera trees. We concluded that the specific gravity (Gb, compression (f c0, and shear parallel to grain (f v0 were ranked in strength classes C30, C40 and C60, respectively, and that volumetric shrinkage (VS was ranked as high. A positive relationship between Gb and f v0 results from the higher specific gravity associated with higher tissue proportion, in turn, causing higher shear strength. Higher ray frequency increases shear strength, because rays act as reinforcing elements. A negative relationship between VS and vessel diameter occurs because vessel walls are highly resistant to collapse, and since larger lumens represent a higher proportion of empty spaces, less tissue is available for shrinkage.

  13. Clays for brick manufacturing in Actopan, Hidalgo: physical, chemical and mineralogical characterization

    Energy Technology Data Exchange (ETDEWEB)

    Moreno-Tovar, Raul; Yañez-Hernández, Osiris Annel; Pérez-Moreno, Fidel; Rodríguez-Lugo, Ventura [Área de Ciencias de la Tierra y Materiales, Universidad Autónoma del Estado de Hidalgo (Mexico); Rivera, José de Jesús Cruz [Universidad Autónoma de San Luis Potosí (Mexico); Rivera, Ana Leonor, E-mail: analeonor.ventura.2016@gmail.com [Universidad Nacional Autónoma de México, DF (Mexico)

    2017-10-15

    Samples of clays from Actopan, Hidalgo employed in brick manufacturing are physical, chemical and mineralogical characterized. Transmitted polarized light microscopy showed a uniform particle size with grain morphology characteristic of euhedral crystals with quartz, feldspars, nontronite, and iron oxides particles. Scanning Electron Microscopy revealed 75 μm to 90 μm wide subhedral structures formed by particles from 2.0 μm to 5.0 μm; and rombohedrales forms 40 μm wide, 70 µm long, constituted of silicon, aluminum, iron, titanium, calcium, minor amounts of potassium, magnesium, and sodium. Minerals such as quartz, albite, cristobalite, calcium and Hematite phases were recognized by X-Ray Diffraction technique. Chemical analysis by atomic emission spectrometry with Inductively Coupled Plasma confirmed this mineralogy composition while laser granulometry method found the same particle size. Grain size analysis determined submicrometric dimensions, and multimodal type curves, that can be interpreted as the mixing of two or more different mineral phases in each sample. (author)

  14. Physical-chemical characterization of the textile dye Azo Ab52 degradation by corona plasma

    Science.gov (United States)

    Gómez, A.; Torres-Arenas, A. J.; Vergara-Sánchez, J.; Torres, C.; Reyes, P. G.; Martínez, H.; Saldarriaga-Noreña, Hugo

    2017-10-01

    This work characterizes the degradation of the textile dye azo Acid Black 52 by measuring several physical and chemical parameters. A corona plasma was created at atmospheric pressure and applied on the liquid-air interface of water samples containing the dye. 1.0 mM of ferrous sulfate (FeSO4) was added to 1.0 mM dye solution, for a total volume of 250 mL. For each treatment, a number of parameters were quantified. These were voltage, current, temperature, loss of volume, pH, electrical conductivity, concentration, optical mission spectra, chemical oxygen demand (COD), total organic carbon (TOC), and the removal ratio. Because of the increase in the sample temperature, the volume lost by evaporation was explored. The results show that the efficiency of the dye degradation by plasma is a function of treatment time. Moreover, the reactive concentration of FeSO4 and the exposition time of the plasma were varied at a constant volume, leading to the determination of the concentrations and optimal times. Considering the degradation and removal parameters, at the maximum treated time of 80 min, it found that COD was of 96.36%, TOC of 93.93%, and the removal ratio of 97.47%.

  15. OARSI recommended performance-based tests to assess physical function in people diagnosed with hip or knee osteoarthritis

    DEFF Research Database (Denmark)

    Dobson, F; Hinman, R S; Roos, Ewa M.

    2013-01-01

    To recommend a consensus-derived set of performance-based tests of physical function for use in people diagnosed with hip or knee osteoarthritis (OA) or following joint replacement.......To recommend a consensus-derived set of performance-based tests of physical function for use in people diagnosed with hip or knee osteoarthritis (OA) or following joint replacement....

  16. Space Launch System Base Heating Test: Environments and Base Flow Physics

    Science.gov (United States)

    Mehta, Manish; Knox, Kyle S.; Seaford, C. Mark; Dufrene, Aaron T.

    2016-01-01

    The NASA Space Launch System (SLS) vehicle is composed of four RS-25 liquid oxygen- hydrogen rocket engines in the core-stage and two 5-segment solid rocket boosters and as a result six hot supersonic plumes interact within the aft section of the vehicle during ight. Due to the complex nature of rocket plume-induced ows within the launch vehicle base during ascent and a new vehicle con guration, sub-scale wind tunnel testing is required to reduce SLS base convective environment uncertainty and design risk levels. This hot- re test program was conducted at the CUBRC Large Energy National Shock (LENS) II short-duration test facility to simulate ight from altitudes of 50 kft to 210 kft. The test program is a challenging and innovative e ort that has not been attempted in 40+ years for a NASA vehicle. This presentation discusses the various trends of base convective heat ux and pressure as a function of altitude at various locations within the core-stage and booster base regions of the two-percent SLS wind tunnel model. In-depth understanding of the base ow physics is presented using the test data, infrared high-speed imaging and theory. The normalized test design environments are compared to various NASA semi- empirical numerical models to determine exceedance and conservatism of the ight scaled test-derived base design environments. Brief discussion of thermal impact to the launch vehicle base components is also presented.

  17. The physical interpretation of the parameters measured during the tensile testing of materials at elevated temperatures

    International Nuclear Information System (INIS)

    Burton, B.

    1984-01-01

    Hot tensile (or compression) testing, where the stress developed in a material is measured under an imposed strain rate, is often used as an alternative to conventional creep testing. The advantages of the hot tensile test are that its duration can be more closely controlled by the experimenter and also that the technique is more convenient, since high precision testing machines are available. The main disadvantage is that the interpretation of results is more complex. The present paper relates the parameters which are measured in hot tensile tests, to physical processes which occur in materials deforming by a variety of mechanisms. For cases where no significant structural changes occur, as in viscous or superplastic flow, analytical expressions are derived which relate the stresses measured in these tests to material constants. When deformation is controlled by recovery processes, account has to be taken of the structural changes which occur concurrently. A wide variety of behaviour may then be exhibited which depends on the initial dislocation density, the presence of second-phase particles and the relative values of the recovery rate parameters and the velocity imposed by the testing machine. Numerical examples are provided for simple recovery models. (author)

  18. Statistical homogeneity tests applied to large data sets from high energy physics experiments

    Science.gov (United States)

    Trusina, J.; Franc, J.; Kůs, V.

    2017-12-01

    Homogeneity tests are used in high energy physics for the verification of simulated Monte Carlo samples, it means if they have the same distribution as a measured data from particle detector. Kolmogorov-Smirnov, χ 2, and Anderson-Darling tests are the most used techniques to assess the samples’ homogeneity. Since MC generators produce plenty of entries from different models, each entry has to be re-weighted to obtain the same sample size as the measured data has. One way of the homogeneity testing is through the binning. If we do not want to lose any information, we can apply generalized tests based on weighted empirical distribution functions. In this paper, we propose such generalized weighted homogeneity tests and introduce some of their asymptotic properties. We present the results based on numerical analysis which focuses on estimations of the type-I error and power of the test. Finally, we present application of our homogeneity tests to data from the experiment DØ in Fermilab.

  19. Assessment of physical performance using the 6-minute walk test in children receiving treatment for cancer.

    Science.gov (United States)

    Hooke, Mary C; Garwick, Ann W; Neglia, Joseph P

    2013-01-01

    The study of physical performance in children with cancer is emerging as an important variable in symptom research. Studies have shown that children with cancer experience deficits in physical performance during treatment that may be present years after therapy. The aim of this study was to determine if distance on the 6-minute walk test (6MWT) changed in children during the first 3 cycles of cancer treatment and to compare the distances walked with healthy norms. This is a secondary data analysis of 19 boys and 10 girls, aged 6 to 17 years, who were newly diagnosed with cancer and were part of a larger study that measured changes in fatigue and physical performance during the first 3 cycles of chemotherapy. Participants performed the 6MWT between days 15 and 29 of the first and third cycles of chemotherapy. Pediatric cancer patients did not have a significant change in the distance walked at cycle 3 of chemotherapy compared with cycle 1. When compared with 2 different normative data sets for healthy children, most children with cancer performed significantly below their peers. Children had poor strength and endurance after 3 cycles of chemotherapy even when their disease was responding to treatment. Interventions are needed to promote rehabilitation and maintenance of physical performance, as both are important to quality of life and ongoing child development. Children receiving cancer treatment who are ambulatory may appear to be functioning normally but are in fact severely deconditioned compared with their healthy peers.

  20. Fabrication and characterization of MCC [Materials Characterization Center] approved testing material---ATM-2, ATM-3, and ATM-4 glasses

    International Nuclear Information System (INIS)

    Wald, J.W.

    1988-03-01

    Materials Characterization Center glasses ATM-2, ATM-3, and ATM-4 are designed to simulate high-level waste glasses that are likely to result from the reprocessing of commercial nuclear reactor fuels. The three Approved Testing Materials (ATMs) are borosilicate glasses based upon the MCC-76-68 glass composition. One radioisotope was added to form each ATM. The radioisotopes added to form ATM-2, ATM-3, and ATM-4 were 241 Am, 237 Np, and 239 Pu, respectively. Each of the ATM lots was produced in a nominal lot size of 450 g from feed stock melted in a nitrogen-atmosphere glove box at 1200/degree/C in a platinum crucible. Each ATM was then cast into bars. Analyzed compositions of these glasses are listed. The nonradioactive elements were analyzed by inductively coupled argon plasma atomic emission spectroscopy (ICP), and the radioisotope analyses were done by alpha energy analysis. Results are discussed. 7 refs., 3 figs., 5 tabs

  1. Characterization of spent fuel elements stored at IEA-R1 research reactor based on visual inspections and sipping tests

    International Nuclear Information System (INIS)

    Silva, Jose Eduardo Rosa da; Terremoto, Luis Antonio Albiac; Teodoro, Celso Antonio; Castanheira, Myrthes; Lucki, Georgi; Damy, Margaret de Almeida; Silva, Antonio Teixeira e

    2005-01-01

    Aluminum spent nuclear fuels are susceptible to corrosion attack, or mechanical damage from improper handling, while in pool reactor storage. Storage practices have been modified to reduce the potential for damage, based on recommendations presented at second WS on Spent Fuel Characterization, promoted by IAEA. In this work, we present the inspection program proposed to the IEA-R1 stored spent fuel elements, in order to provide information on the physical condition during the interim storage time under wet condition at the reactor pool. The inspection program is based on non-destructive tests results (visual inspection and sipping tests) already periodically performed to exam the IEA-R1 stored spent fuel and fuel elements from the core reactor. To record the available information and examination results it was elaborated a document in the format of a catalogue containing the proposed inspection program for the IEA-R1 stored spent fuel, the description of the visual inspection and sipping tests systems, a compilation of information and images result from the tests performed for all stored standard spent fuel element and, in annexes, copies of the reference documents. That document constitutes an important step of the effective implementation of the referred IEA-R1 spent fuel inspection program and can be used to address regulatory and operational needs for the demonstration, for example, of safe storage throughout the pool storage period. (author)

  2. Characterization of spent fuel elements stored at IEA-R1 research reactor based on visual inspections and sipping tests

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Jose Eduardo Rosa da; Terremoto, Luis Antonio Albiac; Teodoro, Celso Antonio; Castanheira, Myrthes; Lucki, Georgi; Damy, Margaret de Almeida; Silva, Antonio Teixeira e [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: jersilva@ipen.br

    2005-07-01

    Aluminum spent nuclear fuels are susceptible to corrosion attack, or mechanical damage from improper handling, while in pool reactor storage. Storage practices have been modified to reduce the potential for damage, based on recommendations presented at second WS on Spent Fuel Characterization, promoted by IAEA. In this work, we present the inspection program proposed to the IEA-R1 stored spent fuel elements, in order to provide information on the physical condition during the interim storage time under wet condition at the reactor pool. The inspection program is based on non-destructive tests results (visual inspection and sipping tests) already periodically performed to exam the IEA-R1 stored spent fuel and fuel elements from the core reactor. To record the available information and examination results it was elaborated a document in the format of a catalogue containing the proposed inspection program for the IEA-R1 stored spent fuel, the description of the visual inspection and sipping tests systems, a compilation of information and images result from the tests performed for all stored standard spent fuel element and, in annexes, copies of the reference documents. That document constitutes an important step of the effective implementation of the referred IEA-R1 spent fuel inspection program and can be used to address regulatory and operational needs for the demonstration, for example, of safe storage throughout the pool storage period. (author)

  3. The prognostic value of electrodiagnostic testing in patients with sciatica receiving physical therapy.

    Science.gov (United States)

    Savage, Nathan J; Fritz, Julie M; Kircher, John C; Thackeray, Anne

    2015-03-01

    To investigate the prognostic value of electrodiagnostic testing in patients with sciatica receiving physical therapy. Electrodiagnostic testing was performed on 38 patients with sciatica participating in a randomized trial comparing different physical therapy interventions. Patients were grouped and analyzed according to the presence or absence of radiculopathy based on electrodiagnostic testing. Longitudinal data analysis was conducted using multilevel growth modeling with ten waves of data collected from baseline through the treatment and post-treatment periods up to 6 months. The primary outcome measure was changes in low back pain-related disability assessed using the Roland and Morris disability questionnaire (RMDQ). Patients with radiculopathy (n = 19) had statistically significant and clinically meaningful improvements in RMDQ scores at every post-treatment follow-up occasion regardless of treatment received. The final multilevel growth model revealed improvements in RMDQ scores in patients with radiculopathy at the 6-week (-8.1, 95 % CI -12.6 to -2.6; P = 0.006) and 6-month (-4.1, 95 % CI -7.4 to -0.7; P = 0.020) follow-up occasions compared to patients without radiculopathy. Treatment group was not a significant predictive factor at any follow-up occasion. An interaction between electrodiagnostic status and time revealed faster weekly improvements in RMDQ scores in patients with radiculopathy at the 6-week (-0.72, 95 % CI -1.4 to -0.04; P = 0.040) through the 16-week (-0.30, 95 % CI, -0.57 to -0.04; P = 0.028) follow-up occasions compared to patients without radiculopathy. The presence of lumbosacral radiculopathy identified with electrodiagnostic testing is a favorable prognostic factor for recovery in low back pain-related disability regardless of physical therapy treatment received.

  4. A systematic review of the diagnostic performance of orthopedic physical examination tests of the hip

    Science.gov (United States)

    2013-01-01

    Background Previous reviews of the diagnostic performances of physical tests of the hip in orthopedics have drawn limited conclusions because of the low to moderate quality of primary studies published in the literature. This systematic review aims to build on these reviews by assessing a broad range of hip pathologies, and employing a more selective approach to the inclusion of studies in order to accurately gauge diagnostic performance for the purposes of making recommendations for clinical practice and future research. It specifically identifies tests which demonstrate strong and moderate diagnostic performance. Methods A systematic search of Medline, Embase, Embase Classic and CINAHL was conducted to identify studies of hip tests. Our selection criteria included an analysis of internal and external validity. We reported diagnostic performance in terms of sensitivity, specificity, predictive values and likelihood ratios. Likelihood ratios were used to identify tests with strong and moderate diagnostic utility. Results Only a small proportion of tests reported in the literature have been assessed in methodologically valid primary studies. 16 studies were included in our review, producing 56 independent test-pathology combinations. Two tests demonstrated strong clinical utility, the patellar-pubic percussion test for excluding radiologically occult hip fractures (negative LR 0.05, 95% Confidence Interval [CI] 0.03-0.08) and the hip abduction sign for diagnosing sarcoglycanopathies in patients with known muscular dystrophies (positive LR 34.29, 95% CI 10.97-122.30). Fifteen tests demonstrated moderate diagnostic utility for diagnosing and/or excluding hip fractures, symptomatic osteoarthritis and loosening of components post-total hip arthroplasty. Conclusions We have identified a number of tests demonstrating strong and moderate diagnostic performance. These findings must be viewed with caution as there are concerns over the methodological quality of the primary

  5. PHYSICS

    CERN Multimedia

    D. Acosta

    2010-01-01

    A remarkable amount of progress has been made in Physics since the last CMS Week in June given the exponential growth in the delivered LHC luminosity. The first major milestone was the delivery of a variety of results to the ICHEP international conference held in Paris this July. For this conference, CMS prepared 15 Physics Analysis Summaries on physics objects and 22 Summaries on new and interesting physics measurements that exploited the luminosity recorded by the CMS detector. The challenge was incorporating the largest batch of luminosity that was delivered only days before the conference (300 nb-1 total). The physics covered from this initial running period spanned hadron production measurements, jet production and properties, electroweak vector boson production, and even glimpses of the top quark. Since then, the accumulated integrated luminosity has increased by a factor of more than 100, and all groups have been working tremendously hard on analysing this dataset. The September Physics Week was held ...

  6. Qinshan CANDU project simulation of reactor physics tests at low power

    International Nuclear Information System (INIS)

    Banica, C.; Tin, E.S.Y.; Mingjun, C.; Shad, M.A.; Schwanke, P.; Jenkins, D.A.

    2003-01-01

    Two new CANDU 6 reactors located in Qinshan, China, have recently been added to AECL's CANDU family. As a result of a very successful project, the first unit entered commercial operation in December 2002. As with all CANDU reactors, a series of physics tests were performed after first criticality was achieved. These tests were presimulated with the RFSP code and the results were compared to the measured data. The Phase-B commissioning is described in this paper, with an emphasis on lessons learned and quality of the fit of the measurements to the presimulations. The measured device reactivity worths in terms of changes in zone controller fills compared well with the results of the presimulations. Good agreement was also obtained between precalculated fluxes at detector locations and measured detector readings for all rundown tests. These results give confidence that the shutdown systems and reactor regulating system are functioning as expected and also provide validation of the Qinshan RFSP model. (author)

  7. Radiological, physical, and chemical characterization of low-level alpha contaminated wastes stored at the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Apel, M.L.; Becker, G.K.; Ragan, Z.K.; Frasure, J.; Raivo, B.D.; Gale, L.G.; Pace, D.P.

    1994-03-01

    This document provides radiological, physical, and chemical characterization data for low-level alpha-contaminated radioactive and low-level alpha-contaminated radioactive and hazardous (i.e., mixed) wastes stored at the Idaho National Engineering Laboratory and considered for treatment under the Private Sector Participation Initiative Program. Waste characterization data are provided in the form of INEL Waste Profile Sheets. These documents provide, for each content code, information on waste identification, waste description, waste storage configuration, physical/chemical waste composition, radionuclide and associated alpha activity waste characterization data, and hazardous constituents present in the waste. Information is provided for 97 waste streams which represent an estimated total volume of 25,450 m 3 corresponding to a total mass of approximately 12,000,000 kg. In addition, considerable information concerning alpha, beta, gamma, and neutron source term data specific to Rocky Flats-generated waste forms stored at the INEL are provided to assist in facility design specification

  8. Radiological, physical, and chemical characterization of low-level alpha contaminated wastes stored at the Idaho National Engineering Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Apel, M.L.; Becker, G.K.; Ragan, Z.K.; Frasure, J.; Raivo, B.D.; Gale, L.G.; Pace, D.P.

    1994-03-01

    This document provides radiological, physical, and chemical characterization data for low-level alpha-contaminated radioactive and low-level alpha-contaminated radioactive and hazardous (i.e., mixed) wastes stored at the Idaho National Engineering Laboratory and considered for treatment under the Private Sector Participation Initiative Program. Waste characterization data are provided in the form of INEL Waste Profile Sheets. These documents provide, for each content code, information on waste identification, waste description, waste storage configuration, physical/chemical waste composition, radionuclide and associated alpha activity waste characterization data, and hazardous constituents present in the waste. Information is provided for 97 waste streams which represent an estimated total volume of 25,450 m 3 corresponding to a total mass of approximately 12,000,000 kg. In addition, considerable information concerning alpha, beta, gamma, and neutron source term data specific to Rocky Flats-generated waste forms stored at the INEL are provided to assist in facility design specification.

  9. Development of Models to Simulate Tracer Tests for Characterization of Enhanced Geothermal Systems

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Mark D.; Reimus, Paul; Vermeul, Vincent R.; Rose, Peter; Dean, Cynthia A.; Watson, Tom B.; Newell, D.; Leecaster, Kevin; Brauser, Eric

    2013-05-01

    A recent report found that power and heat produced from enhanced (or engineered) geothermal systems (EGSs) could have a major impact on the U.S energy production capability while having a minimal impact on the environment. EGS resources differ from high-grade hydrothermal resources in that they lack sufficient temperature distribution, permeability/porosity, fluid saturation, or recharge of reservoir fluids. Therefore, quantitative characterization of temperature distributions and the surface area available for heat transfer in EGS is necessary for the design and commercial development of the geothermal energy of a potential EGS site. The goal of this project is to provide integrated tracer and tracer interpretation tools to facilitate this characterization. This project was initially focused on tracer development with the application of perfluorinated tracer (PFT) compounds, non-reactive tracers used in numerous applications from atmospheric transport to underground leak detection, to geothermal systems, and evaluation of encapsulated PFTs that would release tracers at targeted reservoir temperatures. After the 2011 midyear review and subsequent discussions with the U.S. Department of Energy Geothermal Technology Program (GTP), emphasis was shifted to interpretive tool development, testing, and validation. Subsurface modeling capabilities are an important component of this project for both the design of suitable tracers and the interpretation of data from in situ tracer tests, be they single- or multi-well tests. The purpose of this report is to describe the results of the tracer and model development for simulating and conducting tracer tests for characterizing EGS parameters.

  10. Wave Resource Characterization at US Wave Energy Converter (WEC) Test Sites

    Science.gov (United States)

    Dallman, A.; Neary, V. S.

    2016-02-01

    The US Department of Energy's (DOE) Marine and Hydrokinetic energy (MHK) Program is supporting a diverse research and development portfolio intended to accelerate commercialization of the marine renewable industry by improving technology performance, reducing market barriers, and lowering the cost of energy. Wave resource characterization at potential and existing wave energy converter (WEC) test sites and deployment locations contributes to this DOE goal by providing a catalogue of wave energy resource characteristics, met-ocean data, and site infrastructure information, developed utilizing a consistent methodology. The purpose of the catalogue is to enable the comparison of resource characteristics among sites to facilitate the selection of test sites that are most suitable for a developer's device and that best meet their testing needs and objectives. It also provides inputs for the design of WEC test devices and planning WEC tests, including the planning of deployment and operations and maintenance. The first edition included three sites: the Pacific Marine Energy Center (PMEC) North Energy Test Site (NETS) offshore of Newport, Oregon, the Kaneohe Bay Naval Wave Energy Test Site (WETS) offshore of Oahu, HI, and a potential site offshore of Humboldt Bay, CA (Eureka, CA). The second edition was recently finished, which includes five additional sites: the Jennette's Pier Wave Energy Converter Test Site in North Carolina, the US Army Corps of Engineers (USACE) Field Research Facility (FRF), the PMEC Lake Washington site, the proposed PMEC South Energy Test Site (SETS), and the proposed CalWave Central Coast WEC Test Site. The operational sea states are included according to the IEC Technical Specification on wave energy resource assessment and characterization, with additional information on extreme sea states, weather windows, and representative spectra. The methodology and a summary of results will be discussed.

  11. DESIGN AND CHARACTERIZATION OF A BIOCOMPATIBLE PHYSICAL HYDROGEL BASED ON SCLEROGLUCAN FOR TOPICAL DRUG DELIVERY.

    Science.gov (United States)

    Paolicelli, Patrizia; Varani, Gabriele; Pacelli, Settimio; Ogliani, Elisa; Nardoni, Martina; Petralito, Stefania; Adrover, Alessandra; Casadei, Maria Antonietta

    2017-10-15

    Physical hydrogels of a high-carboxymethylated derivative of scleroglucan (Scl-CM 300 ) were investigated as potential systems for topical drug delivery using three different therapeutic molecules (fluconazole, diclofenac and betamethasone). Rheological tests were carried out on drug-loaded hydrogels along with in-vitro release studies in a vertical Franz cell, in order to investigate if and how different drugs may influence the rheological and release properties of Scl-CM 300 hydrogels. Experimental results and theoretical modeling highlighted that, in the absence of drug/polymer interactions (as for fluconazole and betamethasone) Scl-CM 300 matrices offer negligible resistance to drug diffusion and a Fickian transport model can be adopted to estimate the effective diffusion coefficient in the swollen hydrogel. The presence of weak drug/hydrogel chemical bonds (as for diclofenac), confirmed by frequency sweep tests, slow down the drug release kinetics and a non-Fickian two-phase transport model has to be adopted. In-vivo experiments on rabbits evidenced optimal skin tolerability of Scl-CM 300 hydrogels after topical application. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. PHYSICS

    CERN Multimedia

    P. Sphicas

    The CPT project came to an end in December 2006 and its original scope is now shared among three new areas, namely Computing, Offline and Physics. In the physics area the basic change with respect to the previous system (where the PRS groups were charged with detector and physics object reconstruction and physics analysis) was the split of the detector PRS groups (the old ECAL-egamma, HCAL-jetMET, Tracker-btau and Muons) into two groups each: a Detector Performance Group (DPG) and a Physics Object Group. The DPGs are now led by the Commissioning and Run Coordinator deputy (Darin Acosta) and will appear in the correspond¬ing column in CMS bulletins. On the physics side, the physics object groups are charged with the reconstruction of physics objects, the tuning of the simulation (in collaboration with the DPGs) to reproduce the data, the provision of code for the High-Level Trigger, the optimization of the algorithms involved for the different physics analyses (in collaboration with the analysis gr...

  13. PHYSICS

    CERN Multimedia

    J. Incandela

    There have been numerous developments in the physics area since the September CMS week. The biggest single event was the Physics/Trigger week in the end of Octo¬ber, whereas in terms of ongoing activities the “2007 analyses” went into high gear. This was in parallel with participation in CSA07 by the physics groups. On the or¬ganizational side, the new conveners of the physics groups have been selected, and a new database for man¬aging physics analyses has been deployed. Physics/Trigger week The second Physics-Trigger week of 2007 took place during the week of October 22-26. The first half of the week was dedicated to working group meetings. The ple¬nary Joint Physics-Trigger meeting took place on Wednesday afternoon and focused on the activities of the new Trigger Studies Group (TSG) and trigger monitoring. Both the Physics and Trigger organizations are now focused on readiness for early data-taking. Thus, early trigger tables and preparations for calibr...

  14. Characterization of OT4-1 Alloy by Multi-Dome Forming Test

    Directory of Open Access Journals (Sweden)

    Ivan Zakhariev

    2017-08-01

    Full Text Available In this study, the rheological characteristics of a titanium alloy have been obtained by multi-dome bulging test. Free bulging process is an experimental technique that can be used to characterize material in conditions of biaxial tension during superplastic, as well as conventional, hot forming. The constitutive constants are calculated on a base of the information about the bulge geometry, applied pressure, and forming time. A multi-dome forming test allows one to reduce the number of the experiments required for the characterization, since every multi-dome test produces several domes of different size. In this study, a specific die for multi-dome test was used. The die has six holes with different radiuses of 20, 25, 30, 35, 40, and 45 mm. During a test, the specimen is clamped between blank holder and die holder, heated to a specific temperature, and formed by applying constant gas pressure. The experiments were conducted at different temperatures for OT4-1 titanium alloy. The constitutive constants were obtained by processing the experimental data using two different techniques and compared with tensile test results. In order to estimate the influence of friction on the experimental results and to verify obtained material characteristics, finite element (FE simulation was performed. Finally, the results of FE simulation were compared with the experimental data. The results of the simulation show the advantage of material characterization based on multi dome tests and its interpretation by inverse analysis. The deviations produced by the effect of friction are more significant when the direct approach is applied instead of inverse analysis with a semi analytical model of the bulging process.

  15. International consensus on the most useful physical examination tests used by physiotherapists for patients with headache: A Delphi study.

    Science.gov (United States)

    Luedtke, K; Boissonnault, W; Caspersen, N; Castien, R; Chaibi, A; Falla, D; Fernández-de-Las-Peñas, C; Hall, T; Hirsvang, J R; Horre, T; Hurley, D; Jull, G; Krøll, L S; Madsen, B K; Mallwitz, J; Miller, C; Schäfer, B; Schöttker-Königer, T; Starke, W; von Piekartz, H; Watson, D; Westerhuis, P; May, A

    2016-06-01

    A wide range of physical tests have been published for use in the assessment of musculoskeletal dysfunction in patients with headache. Which tests are used depends on a physiotherapist's clinical and scientific background as there is little guidance on the most clinically useful tests. To identify which physical examination tests international experts in physiotherapy consider the most clinically useful for the assessment of patients with headache. Delphi survey with pre-specified procedures based on a systematic search of the literature for physical examination tests proposed for the assessment of musculoskeletal dysfunction in patients with headache. Seventeen experts completed all three rounds of the survey. Fifteen tests were included in round one with eleven additional tests suggested by the experts. Finally eleven physical examination tests were considered clinically useful: manual joint palpation, the cranio-cervical flexion test, the cervical flexion-rotation test, active range of cervical movement, head forward position, trigger point palpation, muscle tests of the shoulder girdle, passive physiological intervertebral movements, reproduction and resolution of headache symptoms, screening of the thoracic spine, and combined movement tests. Eleven tests are suggested as a minimum standard for the physical examination of musculoskeletal dysfunctions in patients with headache. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Evaluation of the Initial Isothermal Physics Measurements at the Fast Flux Test Facility, a Prototypic Liquid Metal Fast Breeder Reactor

    Energy Technology Data Exchange (ETDEWEB)

    John D. Bess

    2010-03-01

    The Fast Flux Test Facility (FFTF) was a 400-MWt, sodium-cooled, low-pressure, high-temperature, fast-neutron flux, nuclear fission reactor plant designed for the irradiation testing of nuclear reactor fuels and materials for the development of liquid metal fast breeder reactors (LMFBRs). The FFTF was fueled with plutonium-uranium mixed oxide (MOX) and reflected by Inconel-600. Westinghouse Hanford Company operated the FFTF as part of the Hanford Engineering Development Laboratory (HEDL) for the U.S. Department of Energy on the Hanford Site near Richland, Washington. Although the FFTF was a testing facility not specifically designed to breed fuel or produce electricity, it did provide valuable information for LMFBR projects and base technology programs in the areas of plant system and component design, component fabrication, prototype testing, and site construction. The major objectives of the FFTF were to provide a strong, disciplined engineering base for the LMFBR program, provide fast flux testing for other U.S. programs, and contribute to the development of a viable self-sustaining competitive U.S. LMFBR industry. During its ten years of operation, the FFTF acted as a national research facility to test advanced nuclear fuels, materials, components, systems, nuclear power plant operating and maintenance procedures, and active and passive reactor safety technologies; it also produced a large number of isotopes for medical and industrial users, generated tritium for the U.S. fusion research program, and participated in cooperative, international research work. Prior to the implementation of the reactor characterization program, a series of isothermal physics measurements were performed; this acceptance testing program consisted of a series of control rod worths, critical rod positions, subcriticality measurements, maximum reactivity addition rates, shutdown margins, excess reactivity, and isothermal temperature coefficient reactivity. The results of these

  17. Large-scale in situ heater tests for hydrothermal characterization at Yucca Mountain

    International Nuclear Information System (INIS)

    Buscheck, T.A.; Wilder, D.G.; Nitao, J.J.

    1993-01-01

    To safely and permanently store high-level nuclear waste, the potential Yucca Mountain repository site must mitigate the release and transport of radionuclides for tens of thousands of years. In the failure scenario of greatest concern, water would contact a waste package, accelerate its failure rate, and eventually transport radionuclides to the water table. Our analyses indicate that the ambient hydrological system will be dominated by repository-heat-driven hydrothermal flow for tens of thousands of years. In situ heater tests are required to provide an understanding of coupled geomechanical-hydrothermal-geochemical behavior in the engineered and natural barriers under repository thermal loading conditions. In situ heater tests have been included in the Site Characterization Plan in response to regulatory requirements for site characterization and to support the validation of process models required to assess the total systems performance at the site. Because of limited time, some of the in situ tests will have to be accelerated relative to actual thermal loading conditions. We examine the trade-offs between the limited test duration and generating hydrothermal conditions applicable to repository performance during the entire thermal loading cycle, including heating (boiling and dry-out) and cooldown (re-wetting). For in situ heater tests to be applicable to actual repository conditions, a minimum heater test duration of 6-7 yr (including 4 yr of full-power heating) is required

  18. The study features of test procedures of students' knowledge on the physical training lessons

    Directory of Open Access Journals (Sweden)

    Korobejnik V.A.

    2013-09-01

    Full Text Available The aim is to determine the significance of the relationship and special professional skills necessary to detect and correct errors and evaluating students in physical education classes. The surveys were a group of qualified teachers (n = 31 with different pedagogical experience. Each teacher was asked to arrange the professional quality of the places from 1 to 10. It was found that all investigated have a certain quality and a high level of relationship, but they are manifested in different periods of teaching. It is shown that the process of organizing and carrying out checks of expertise includes logically related mental operations which are the basis of test procedures of students' knowledge on the physical training lessons. Found that the most weighty qualities were related to skills: a rating, comment exposed estimate visually identify the error and determine its significance.

  19. Physical capacity and the motor tests relative for the health promotion in children and adolescents

    Directory of Open Access Journals (Sweden)

    Roberto Jerônimo dos Santos Silva

    2003-06-01

    Full Text Available This article discusses physical capacity and health-promotion-oriented motor tests in children and adolescents, in order to provide a foundation for future studies that intend to debate this topic. The idea of evaluating physical activity levels in a population is aimed to determine the level of physical fi tness, and to verify that this is in line with criteria for good health. From a functional point of view, .good health is defined by the following components: body composition (not considered in this article, strength, muscular endurance capacity and fl exibility. These components are measured by test batteries that are intended to measure the health of individuals and/or populations. The starting point for this debate is the published reference literature that classifi es motor tests as either norm-referenced or criterion-referenced standards. RESUMO Este artigo discute as capacidades físicas e os testes motores voltados à promoção da saúde em crianças e adolescentes, de forma a subsidiar trabalhos em que este tema esteja em voga. A idéia de avaliar a atividade física em uma população é baseada no desejo de determinar o estado de atividade atual da mesma, e verifi car se ela está de acordo com os critérios apropriados para uma boa saúde. Do ponto de vista morfofuncional, uma boa “saúde relatada” é defi nida a partir dos componentes: composição corporal (não abordado neste trabalho, força e resistência muscular e fl exibilidade, componentes estes que são verifi cados a partir da aplicação de testes ou baterias de testes que pretendem medir e verifi car os níveis individuais e/ou populacionais de saúde relatada. A literatura de referência, que classifi ca os testes motores como referenciados a partir de normas ou critérios é o ponto de partida para esse debate.

  20. Primacy effects induced by temporal or physical context shifts are attenuated by a preshift test trial

    Science.gov (United States)

    Wheeler, Daniel S.; Miller, Ralph R.

    2007-01-01

    When subjects are sequentially trained with a cue (A) paired separately with two outcomes (B and C) in different phases (i.e., A–B pairings followed by A–C pairings) testing in the training context after short retention intervals often reveals recency effects (i.e., stronger influence by A–C). In contrast, testing after long retention intervals or testing in a context different from that of training sometimes reveals primacy effects (A–B). Three experiments were conducted using rats in a Pavlovian conditioned bar-press suppression preparation to ascertain whether a nonreinforced test trial in the training context soon after training can attenuate this shift to primacy. Experiment 1 demonstrated that exposure to A shortly after both phases of training, but prior to a long retention interval, can attenuate shifts from recency to primacy otherwise observed with a long retention interval. Experiment 2 showed that exposure to A in the training context can also eliminate the shift from recency to primacy otherwise produced by shifting the physical context between training and test. Experiment 3 discredited a potential account of the results of Experiments 1 and 2. The effects observed in Experiment 1 and 2 are interpreted as early testing in the training context serving to initiate rehearsal of the A–C association due to the temporal proximity of A–C training. PMID:17389907

  1. Fuel Thermo-physical Characterization Project. Fiscal Year 2014 Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Burkes, Douglas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Casella, Andrew M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Buck, Edgar C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Casella, Amanda J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Edwards, Matthew K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); MacFarlan, Paul J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Pool, Karl N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Slonecker, Bruce D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Smith, Frances N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Steen, Franciska H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-15

    The Office of Material Management and Minimization (M3) Reactor Conversion Fuel Thermo-Physical Characterization Project at Pacific Northwest National Laboratory (PNNL) was tasked with using PNNL facilities and processes to receive irradiated low enriched uranium–molybdenum (LEU-Mo) fuel plate samples and perform analysis in support of the M3 Reactor Conversion Program. This work is in support of the M3 Reactor Conversion Fuel Development Pillar that is managed by Idaho National Laboratory. The primary research scope was to determine the thermo-physical properties as a function of temperature and burnup. Work conducted in Fiscal Year (FY) 2014 complemented measurements performed in FY 2013 on four additional irradiated LEU-Mo fuel plate samples. Specifically, the work in FY 2014 investigated the influence of different processing methods on thermal property behavior, the absence of aluminum alloy cladding on thermal property behavior for additional model validation, and the influence of higher operating surface heat flux / more aggressive irradiation conditions on thermal property behavior. The model developed in FY 2013 and refined in FY 2014 to extract thermal properties of the U-Mo alloy from the measurements conducted on an integral fuel plate sample (i.e., U-Mo alloy with a thin Zr coating and clad in AA6061) continues to perform very well. Measurements conducted in FY 2014 on samples irradiated under similar conditions compare well to measurements performed in FY 2013. In general, there is no gross influence of fabrication method on thermal property behavior, although the difference in LEU-Mo foil microstructure does have a noticeable influence on recrystallization of grains during irradiation. Samples irradiated under more aggressive irradiation conditions, e.g., higher surface heat flux, revealed lower thermal conductivity when compared to samples irradiated at moderate surface heat fluxes, with the exception of one sample. This report documents thermal

  2. Plant Outage Time Savings Provided by Subcritical Physics Testing at Vogtle Unit 2

    International Nuclear Information System (INIS)

    Cupp, Philip; Heibel, M.D.

    2006-01-01

    The most recent core reload design verification physics testing done at Southern Nuclear Company's (SNC) Vogtle Unit 2, performed prior to initial power operations in operating cycle 12, was successfully completed while the reactor was at least 1% ΔK/K subcritical. The testing program used was the first application of the Subcritical Physics Testing (SPT) program developed by the Westinghouse Electric Company LLC. The SPT program centers on the application of the Westinghouse Subcritical Rod Worth Measurement (SRWM) methodology that was developed in cooperation with the Vogtle Reactor Engineering staff. The SRWM methodology received U. S. Nuclear Regulatory Commission (NRC) approval in August of 2005. The first application of the SPT program occurred at Vogtle Unit 2 in October of 2005. The results of the core design verification measurements obtained during the SPT program demonstrated excellent agreement with prediction, demonstrating that the predicted core characteristics were in excellent agreement with the actual operating characteristics of the core. This paper presents an overview of the SPT Program used at Vogtle Unit 2 during operating cycle 12, and a discussion of the critical path outage time savings the SPT program is capable of providing. (authors)

  3. Detecting forest structure and biomass with C-band multipolarization radar - Physical model and field tests

    Science.gov (United States)

    Westman, Walter E.; Paris, Jack F.

    1987-01-01

    The ability of C-band radar (4.75 GHz) to discriminate features of forest structure, including biomass, is tested using a truck-mounted scatterometer for field tests on a 1.5-3.0 m pygmy forest of cypress (Cupressus pygmaea) and pine (Pinus contorta ssp, Bolanderi) near Mendocino, CA. In all, 31 structural variables of the forest are quantified at seven sites. Also measured was the backscatter from a life-sized physical model of the pygmy forest, composed of nine wooden trees with 'leafy branches' of sponge-wrapped dowels. This model enabled independent testing of the effects of stem, branch, and leafy branch biomass, branch angle, and moisture content on radar backscatter. Field results suggested that surface area of leaves played a greater role in leaf scattering properties than leaf biomass per se. Tree leaf area index was strongly correlated with vertically polarized power backscatter (r = 0.94; P less than 0.01). Field results suggested that the scattering role of leaf water is enhanced as leaf surface area per unit leaf mass increases; i.e., as the moist scattering surfaces become more dispersed. Fog condensate caused a measurable rise in forest backscatter, both from surface and internal rises in water content. Tree branch mass per unit area was highly correlated with cross-polarized backscatter in the field (r = 0.93; P less than 0.01), a result also seen in the physical model.

  4. Physical-chemical and mechanical testing of membranes of chitosan with copper, zinc and magnesium

    International Nuclear Information System (INIS)

    Cardoso, M.J.B.; Barbosa, R.C.; Ries, A.; Fidelis, T.; Fook, M.V.L.

    2012-01-01

    The objective of this work was to evaluate the influence of copper, zinc and magnesium ions on the mechanical and physical chemical properties of chitosan membranes. The membranes were prepared by solvent evaporation method and characterized by Fourier Transform Infrared Spectroscopy, Scanning Electron Microscopy, X-ray diffraction, Superficial Tension and Mechanical Stress-Strain Analysis. From the results could be conclude that the incorporation of metals into chitosan membranes, did not modify the characteristic profile of the membranes. However, the metal containing membranes presented minor flexibility and greater fragility. This is associated to the chelation of metallic ions by chitosan, resulting in a linking between chitosan chains, thus reducing the structural flexibility of the membranes. (author)

  5. PREPARATION, CHARACTERIZATION, AND CATALYTIC ACTIVITY TEST OF Ni-Mo/NATURAL ZEOLITE ON PYRIDINE HYDRODENITROGENATION

    Directory of Open Access Journals (Sweden)

    Sri Kadarwati

    2010-12-01

    Full Text Available Preparation, characterization, and catalytic activity test of Ni-Mo/natural zeolite on pyridine hydrodenitrogenation were carried out. Preparation of catalyst was conducted by impregnation method using nickel nitrate hexahydrate and ammonium heptamolibdate precursor as Ni and Mo source respectively. Characterization of catalyst was conducted by using gravimetry, atomic absorption spectrophotometry, and X-ray diffraction method. Catalytic activity test on pyridine hydrodenitrogenation was carried out by using flow system reactor with hydrogen flow rate variable. The research results showed that the catalyst's total acidity and crystallinity are increased with level of impregnation success of 96.71% and 90.08% respectively. Ni-Mo/natural zeolites able to increase the catalytic conversion up to 71.78% at 350 °C and hydrogen flow rate of 10 mL/min with more highly varied product distribution. Assuming that the pyridine hydrodenitrogenation follows the pseudo first order kinetics.

  6. Characterization ReportOperational Closure Covers for the Area 5 Radioactive Waste Management Site at the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Bechtel Nevada Geotechnical Sciences

    2005-06-01

    Bechtel Nevada (BN) manages two low-level Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site (NTS) for the U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Site Office (NNSA/NSO). The Area 3 RWMS is located in south-central Yucca Flat and the Area 5 RWMS is located about 15 miles south, in north-central Frenchman Flat. Though located in two separate topographically closed basins, they are similar in climate and hydrogeologic setting. The Area 5 RWMS uses engineered shallow-land burial cells to dispose of packaged waste, while the Area 3 RWMS uses subsidence craters formed from underground testing of nuclear weapons for the disposal of packaged and unpackaged bulk waste. Over the next several decades, most waste disposal units at both the Area 3 and Area 5 RWMSs are anticipated to be closed. Closure of the Area 3 and Area 5 RWMSs will proceed through three phases: operational closure, final closure, and institutional control. Many waste disposal units at the Area 5RWMS are operationally closed and final closure has been placed on one unit at the Area 3 RWMS (U-3ax/bl). Because of the similarities between the two sites (e.g., type of wastes, environmental factors, operational closure cover designs, etc.), many characterization studies and data collected at the Area 3 RWMS are relevant and applicable to the Area 5 RWMS. For this reason, data and closure strategies from the Area 3 RWMS are referred to as applicable. This document is an interim Characterization Report – Operational Closure Covers, for the Area 5 RWMS. The report briefly describes the Area 5 RWMS and the physical environment where it is located, identifies the regulatory requirements, reviews the approach and schedule for closing, summarizes the monitoring programs, summarizes characterization studies and results, and then presents conclusions and recommendations.

  7. Characterization Report Operational Closure Covers for the Area 5 Radioactive Waste Management Site at the Nevada Test Site

    International Nuclear Information System (INIS)

    Bechtel Nevada Geotechnical Sciences

    2005-01-01

    Bechtel Nevada (BN) manages two low-level Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site (NTS) for the U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Site Office (NNSA/NSO). The Area 3 RWMS is located in south-central Yucca Flat and the Area 5 RWMS is located about 15 miles south, in north-central Frenchman Flat. Though located in two separate topographically closed basins, they are similar in climate and hydrogeologic setting. The Area 5 RWMS uses engineered shallow-land burial cells to dispose of packaged waste, while the Area 3 RWMS uses subsidence craters formed from underground testing of nuclear weapons for the disposal of packaged and unpackaged bulk waste. Over the next several decades, most waste disposal units at both the Area 3 and Area 5 RWMSs are anticipated to be closed. Closure of the Area 3 and Area 5 RWMSs will proceed through three phases: operational closure, final closure, and institutional control. Many waste disposal units at the Area 5RWMS are operationally closed and final closure has been placed on one unit at the Area 3 RWMS (U-3ax/bl). Because of the similarities between the two sites (e.g., type of wastes, environmental factors, operational closure cover designs, etc.), many characterization studies and data collected at the Area 3 RWMS are relevant and applicable to the Area 5 RWMS. For this reason, data and closure strategies from the Area 3 RWMS are referred to as applicable. This document is an interim Characterization Report - Operational Closure Covers, for the Area 5 RWMS. The report briefly describes the Area 5 RWMS and the physical environment where it is located, identifies the regulatory requirements, reviews the approach and schedule for closing, summarizes the monitoring programs, summarizes characterization studies and results, and then presents conclusions and recommendations

  8. PHYSICS

    CERN Document Server

    Submitted by

    Physics Week: plenary meeting on physics groups plans for startup (14–15 May 2008) The Physics Objects (POG) and Physics Analysis (PAG) Groups presented their latest developments at the plenary meeting during the Physics Week. In the presentations particular attention was given to startup plans and readiness for data-taking. Many results based on the recent cosmic run were shown. A special Workshop on SUSY, described in a separate section, took place the day before the plenary. At the meeting, we had also two special DPG presentations on “Tracker and Muon alignment with CRAFT” (Ernesto Migliore) and “Calorimeter studies with CRAFT” (Chiara Rovelli). We had also a report from Offline (Andrea Rizzi) and Computing (Markus Klute) on the San Diego Workshop, described elsewhere in this bulletin. Tracking group (Boris Mangano). The level of sophistication of the tracking software increased significantly over the last few months: V0 (K0 and Λ) reconstr...

  9. Material characterization and non destructive testing by ultrasounds; modelling, simulation and experimental validation

    International Nuclear Information System (INIS)

    Noroy-Nadal, M.H.

    2002-06-01

    This memory presents the research concerning the characterization of materials and the Non Destructive Testing (N.D.T) by ultrasonics. The different topics include three steps: modeling, computations and experimental validation. The studied materials concern mainly metals. The memory is divided in four parts. The first one concerns the characterization of materials versus temperature. The determination of the shear modulus G(T) is especially studied for a large temperature range, and around the melting point. The second part is devoted to studies by photothermal devices essentially focused on the modeling of the mechanical displacement and the stress field in coated materials. In this particular field of interest, applications concern either the mechanical characterization of the coating, the defect detection in the structure and finally the evaluation of the coating adhesion. The third section is dedicated to microstructural characterization using acoustic microscopy. The evaluation of crystallographic texture is especially approached, for metallic objects obtained by forming. Before concluding and pointing out some perspectives to this work, the last section concerns the introduction of optimization techniques, applied to the material characterization by acoustic microscopy. (author)

  10. Correlation between the results of three physical fitness tests (endurance, strength, speed) and the output measured during a bicycle ergometer test in a cohort of military servicemen.

    Science.gov (United States)

    Sammito, Stefan; Gundlach, Nils; Böckelmann, Irina

    2016-01-01

    Physical fitness tests are widely used to assess endurance, sprint ability, coordination and/or strength. The objective of the present study was to analyze the degree to which the results of the Bundeswehr Basis Fitness Test (BFT)--a physical fitness test comprising a sprint test (11 × 10-m shuttle test), a flexed-arm hang test and a 1000-m run--are consistent with the output measured during a bicycle ergometer test. The number of false-positive and false-negative results with regard to the assessment of physical fitness were also examined. As part of a retrospective study, health assessments from 323 reenlistment examinations were evaluated regarding the output measured during a bicycle ergometer test and compared with the BFT results of the candidates. Overall, a good correlation was shown between the bicycle ergometer test results and the results achieved in the BFT disciplines. All three disciplines of the BFT showed a highly significant correlation with the relative output achieved during the bicycle ergometer test (P < 0.001), and also, the overall BFT score was highly significantly correlated (P < 0.001). The overall rate of false-positive and false-negative results was 4.0 %. The BFT results measured in the three physical fitness test items were highly correlated with the output measured during the bicycle ergometer tests. The rate of false-positive and false-negative results was low. The test items thus represent an appropriate measurement instrument because the test items require few equipment and less time. Additionally, a large number of subjects can be assessed. We suggest that it would be more useful to assess the physical fitness of this special group exclusively on the basis of the BFT instead of using the bicycle ergometer test.

  11. Characterization and structural integrity tests of ex-service steam generator tubes at Ontario Power Generation

    Energy Technology Data Exchange (ETDEWEB)

    Pagan, Sandra [Ontario Power Generation, 889 Brock Road, Pickering, Ontario (Canada); Duan Xinjian [Atomic Energy of Canada Limited, 2251 Speakman Drive, Mississauga, Ontario (Canada)], E-mail: duanx@aecl.ca; Kozluk, Michael J. [Atomic Energy of Canada Limited, 2251 Speakman Drive, Mississauga, Ontario (Canada); Mills, Brian; Goszczynski, Guylaine [Kinectrics Inc., 800 Kipling Avenue, Toronto, Ontario (Canada)

    2009-03-15

    The Canadian Nuclear Standard CSA N285.4 requires the periodic metallurgical examination of removed ex-service steam generator tubes. This paper describes the practices used for the characterization and structural integrity tests of ex-service steam generator tubes at Ontario Power Generation (OPG). It shows that there is no degradation of mechanical properties of Monel 400 tubes after 7-18 effective full power years (EFPY) of operation and Incoloy 800 tubes after more than 10 EFPY of operation.

  12. Performance Model for High-Power Lithium Titanate Oxide Batteries based on Extended Characterization Tests

    DEFF Research Database (Denmark)

    Stroe, Ana-Irina; Swierczynski, Maciej Jozef; Stroe, Daniel Ioan

    2015-01-01

    Lithium-ion (Li-ion) batteries are found nowadays not only in portable/consumer electronics but also in more power demanding applications, such as stationary renewable energy storage, automotive and back-up power supply, because of their superior characteristics in comparison to other energy stor...... model for a commercially available 13Ah high-power lithium titanate oxide battery cell based on laboratory-performed extended characterization tests....

  13. Quantitative cognitive-test characterization of reconnectable implantable fiber-optic neurointerfaces for optogenetic neurostimulation.

    Science.gov (United States)

    Fedotov, I V; Ivashkina, O I; Pochechuev, M S; Roshchina, M A; Toropova, K A; Fedotov, A B; Anokhin, K V; Zheltikov, A M

    2017-11-01

    Cognitive tests on representative groups of freely behaving transgenic mice are shown to enable a quantitative characterization of reconnectable implantable fiber-optic neurointerfaces for optogenetic neurostimulation. A systematic analysis of such tests provides a robust quantitative measure for the cognitive effects induced by fiber-optic neurostimulation, validating the performance of fiber-optic neurointerfaces for long-term optogenetic brain stimulations and showing no statistically significant artifacts in the behavior of transgenic mice due to interface implantation. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Reactive physical vapor deposition of TixAlyN: Integrated plasma-surface modeling characterization

    International Nuclear Information System (INIS)

    Zhang Da; Schaeffer, J.K.

    2004-01-01

    Reactive physical vapor deposition (RPVD) has been widely applied in the microelectronic industry for producing thin films. Fundamental understanding of RPVD mechanisms is needed for successful process development due to the high sensitivity of film properties on process conditions. An integrated plasma equipment-target nitridation modeling infrastructure for RPVD has therefore been developed to provide mechanistic insights and assist optimal process design. The target nitridation model computes target nitride coverage based on self-consistently derived plasma characteristics from the plasma equipment model; target sputter yields needed in the plasma equipment model are also self-consistently derived taking into account the yield-suppressing effect from nitridation. The integrated modeling infrastructure has been applied to investigating RPVD processing with a Ti 0.8 Al 0.2 compound target and an Ar/N 2 gas supply. It has been found that the process produces athermal metal neutrals as the primary deposition precursor. The metal stoichiometry in the deposited film is close to the target composition due to the predominance of athermal species in the flux that reaches the substrate. Correlations between process parameters (N 2 flow, target power), plasma characteristics, surface conditions, and deposition kinetics have been studied with the model. The deposition process is characterized by two regimes when the N 2 flow rate is varied. When N 2 is dilute relative to argon, target nitride coverage increases rapidly with increasing N 2 flow. The sputter yield and deposition rate consequently decrease. For less dilute N 2 mixtures, the sputter yield and deposition rate are stable due to the saturation of target nitridation. With increasing target power, the electron density increases nearly linearly while the variation of N generation is much smaller. Target nitridation and its suppression of the sputter yield saturate at high N 2 flow rendering these parameters

  15. Characterization, modelization and optimization of the Double Chooz acrylic vessels: physics impact

    International Nuclear Information System (INIS)

    Queval, R.

    2010-01-01

    Double Chooz is one of the new generation experiments designed to measure the last unknown leptonic mixing angle, θ 13 . Il studies the oscillations of electronic antineutrinos produced by the Chooz nuclear power plant. Our knowledge on θ 13 can be improved by reducing both statistical errors (increasing both the detector size and run time) and systematic errors (using identical near and far detectors). Also, special care is dedicated to analyze backgrounds generated by natural radioactivity and cosmic ray interactions. The work presented here mostly focuses on Target and Gamma Catcher acrylic vessels, in the core of the detector. A new material designed for the experiment was developed since no pre-existing material met the required conditions. This material was characterized optically, to maximize light transmission and reduce the induced dead zone. With this in mind, a physics study of the Target vessel design was performed to identify any spectral distortion or count rate modification it could induce. As far as backgrounds are concerned, the material is radio-pure enough so that the singles rate coming from acrylic is negligible compared to the one from the photomultiplier tubes. An unknown single source is coming from the external contamination in the detector, such as dust. This is why we defined cleanliness goals for the detector fabrication and integration. These goals were met, thanks to well-defined protocols and careful team work. After three years of data taking, Double Chooz could disentangle an oscillation signal at 3α for sin 2 2θ 13 ≥ 0.05 - 0.06. If no oscillations were observed, the experiment could give an upper limit on sin 2 2θ 13 of 0.02 - 0.03 at 90 % C.L. (author) [fr

  16. Physical and mechanical characterization of Portland cement mortars made with expanded polystyrene particles addition (EPS

    Directory of Open Access Journals (Sweden)

    Ferrándiz-Mas, V.

    2012-12-01

    Full Text Available On this work the influence of the addition of different types (commercial and recycled and contents of expanded polystyrene on the physical and mechanical properties of Portland cement mortars has been studied. Variables studied are: workability, air content, bulk density, mechanical strength, porosity, water absorption and sound absorption. Mixtures have been also characterized by scanning electron microscopy. Air-entraining agents, water retainer and superplasticizer additives have been used in order to improve the workability of mortars. The results show that the workability and mechanical strength decreases with increasing content of expanded polystyrene. Additives improve the workability and porosity, allowing manufacture mortars with high levels of recycled material that show mechanical properties suitable for use as masonry mortars, stucco and plaster.

    El objetivo de este estudio es evaluar la influencia de la adición de distintos tipos y dosificaciones de poliestireno expandido, tanto comerciales como procedentes de reciclado, sobre las características físicas y mecánicas de morteros de cemento portland. Las variables estudiadas fueron: consistencia, aire ocluido, densidad aparente, resistencias mecánicas, porosidad, absorción de agua y absorción acústica. Los morteros también se han caracterizado por microscopia electrónica de barrido. Con objeto de mejorar la trabajabilidad de los morteros se ha empleado aditivos aireante, retenedor de agua y fluidificante. Los resultados muestran que al aumentar la cantidad de poliestireno expandido la trabajabilidad y las resistencias mecánicas disminuyen. El empleo de aditivos mejora la trabajabilidad y la porosidad, permitiendo fabricar morteros con altos contenidos de residuo, con propiedades mecánicas adecuadas para su empleo como morteros de albañilería, revoco y enlucido.

  17. Characterization and Leach Testing for PUREX Cladding Waste Sludge (Group 3) and REDOX Cladding Waste Sludge (Group 4) Actual Waste Sample Composites

    Energy Technology Data Exchange (ETDEWEB)

    Snow, Lanee A.; Buck, Edgar C.; Casella, Amanda J.; Crum, Jarrod V.; Daniel, Richard C.; Draper, Kathryn E.; Edwards, Matthew K.; Fiskum, Sandra K.; Jagoda, Lynette K.; Jenson, Evan D.; Kozelisky, Anne E.; MacFarlan, Paul J.; Peterson, Reid A.; Swoboda, Robert G.

    2009-02-13

    A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan.(a) The testing program was subdivided into logical increments. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. The actual wastetesting program included homogenizing the samples by group, characterizing the solids and aqueous phases, and performing parametric leaching tests. Two of the eight defined groups—plutonium-uranium extraction (PUREX) cladding waste sludge (Group 3, or CWP) and reduction-oxidation (REDOX) cladding waste sludge (Group 4, or CWR)—are the subjects of this report. Both the Group 3 and 4 waste composites were anticipated to be high in gibbsite, requiring caustic leaching. Characterization of the composite Group 3 and Group 4 waste samples confirmed them to be high in gibbsite. The focus of the Group 3 and 4 testing was on determining the behavior of gibbsite during caustic leaching. The waste-type definition, archived sample conditions, homogenization activities, characterization (physical, chemical, radioisotope, and crystal habit), and caustic leaching behavior as functions of time, temperature, and hydroxide concentration are discussed in this report. Testing was conducted according to TP-RPP-WTP-467.

  18. Material characterization of Inconel 718 from free bulging test at high temperature

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Joon Tae; Yoon, Jong Hoon; Lee, Ho Sung [Korea Aerospace Research Institute, Daejeon (Korea, Republic of); Youn, Sung Kie [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2012-07-15

    Macroscopic superplastic behavior of metallic or non metallic materials is usually represented by the strain rate sensitivity, and it can be determined by tensile tests in uniaxial stress state and bulging tests in multi axial stress state, which is the actual hot forming process. And macroscopic behavior of Non SPF grade materials could be described in a similar way as that of superplastic materials, including strain hardening, cavity and so on. In this study, the material characterization of non SPF grade Inconel 718 has been carried out to determine the material parameters for flow stress throughout free bulging test under constant temperature. The measured height of bulged plate during the test was used for estimation of strain rate sensitivity, strain hardening index and cavity volume fraction with the help of numerical analysis. The bulged height obtained from the simulation showed good agreement with the experimental findings. The effects of strain hardening and cavity volume fraction factor for flow stress were also compared.

  19. An evaluation of slug interference tests for aquifer characterization at the Hanford Site

    International Nuclear Information System (INIS)

    Spane, F.A. Jr.; Thorne, P.D.

    1992-01-01

    Slug interference tests are conducted by instantaneously changing the water level in a well and monitoring the aquifer response at one or more observation wells. The applicability of this method for hydraulic characterization of a high permeability unconfined aquifer at the Hanford Site was evaluated. Analytical techniques were used to predict slug interference responses over a range of aquifer hydraulic conditions and observation well distances. This was followed by a field test of the proposed technique. The results showed that slug interference testing can be used to characterize aquifers having transmissivities up to 10 -1 m 2 /s compared to a maximum transmissivity of about 10 -3 m 2 /s for single-well slug tests. The amplitude of the pressure response measured at the observation well is primarily determined by aquifer storativity, while the time-lag of the pressure peak is mainly controlled by the transmissivity. Several recommendations are made optimizing the results of slug interference tests in higher permeability, unconfined to semiconfined aquifers

  20. Surface feature characterization test plan: Conceptual design of a high level nuclear waste repository in salt

    International Nuclear Information System (INIS)

    1984-06-01

    This report presents the Surface Feature Characterization Test Plan for conceptual design. The Test Plan is part of the surface feature characterization program for conceptual design which will obtain information on site topography, hydrology, stratigraphy, and soil and rock engineering properties. The information will be obtained by the Geologic Project Manager (GPM). This Test Plan provides guidance to the GPM as to (1) the kinds of data to be collected, (2) anticipated methods, (3) the level of detail required, (4) interpretation to be made, and (5) the format for presentation. Based on this Test Plan and on conditions at the site that is selected, the GPM will develop an Activity Plan describing the methods to be used in obtaining the needed information. For each item of information, the Test Plan describes those facilities which require it for their design. The GPM can then determine the appropriate methods and level of effort for obtaining the information, taking into account its use and conditions at the selected site. 7 figs., 3 tabs